Product Range Catalog CA04020001Z EN 127323 2
127323-Catalog 1 127323-Catalog_1 127323-Catalog_1 Batch9 unilog cesco-content
2014-10-22
: Pdf 127323-Catalog 2 127323-Catalog_2 Batch9 unilog
Open the PDF directly: View PDF .
Page Count: 177
Download | |
Open PDF In Browser | View PDF |
DC1/DA1 and SVX/SPX variable frequency drives DS7 and S801+/S811+ soft starters Rapid Link 4.0 distributed, electronic drive system Product range catalog for variable frequency drives, soft starters, Rapid Link Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it’s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers’ most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit www.eaton.eu. To contact an Eaton salesperson or local distributor/agent, please visit www.eaton.eu/electrical/customersupport Product range catalog Efficient Engineering for starting and controlling motors. Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton internet pages and Eaton order confirmations. Eaton Industries GmbH Hein-Moeller-Str. 7–11 D-53115 Bonn / Germany © 2012 by Eaton Corporation All rights reserved Printed in Germany 07/13 Publication No.: CA04020001Z_EN-INT Doku/DHW/ip/MP 07/13 Article No.: 170504 CA04020001Z-EN-INT_Umschlag.indd 4-6 Eaton is a registered trademark of Eaton Corporation All other trademarks are property of their respective owners. SmartWire-DT® is a registered trademark of Eaton Corporation. 09.07.13 13:19 Eaton Online Catalog – find product details quickly and efficiently! You can find comprehensive up-to-date product information at http://ecat.moeller.net Lookup You can search by keywords, product names, article numbers, technical data: The search understands everything and takes you straight to the product you’re looking for. Graphical navigation Graphical representation of the fields of application and product groups. Selection aids Tailored to the typical expert’s approach, this search aid helps you quickly find the product you need. HTML data sheet; can be saved as PDF file. Data sheets For every article the catalog can generate a technical data sheet, which you can convert to a PDF file for printing or saving with a single click. Parts lists From your search results you can create a parts list that you can then send to your Eaton sales partner as a query. Parts list, e.g. for queries to Eaton Sales. The power of fusion. You can find comprehensive up-to-date information about Eaton’s automation products and switchgear in our Online Catalog. 1833 1874 1886 1893 1897 1899 1906 1908 1911 1914 1934 1961 1962 1963 1967 1977 1983 1984 1989 There’s a certain energy at Eaton. It’s the power of uniting some of the world’s most respected names to build a brand you can trust to meet your every power management need. Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it’s needed most. Building on over 100 years of experience in electrical power management, the experts at Eaton deliver customized, integrated solutions to solve your most critical challenges. To learn more visit www.eaton.eu/electrical. All of the above are trademarks of Eaton or its affiliates. Eaton has a license to use the Westinghouse brand name in Asia Pacific. ©2013 Eaton. CA04020001Z-EN-INT_Umschlag.indd 7-9 09.07.13 13:20 Page 78 Page 104 S801+, S811+ soft starters Page 132 Rapid Link distributed, electronic drive system Page 152 SmartWire-DT™ communication system Page 178 Appendix Page 189 DC1, DA1 variable frequency drives Appendix SmartWire-DT™ Rapid Link DS7 soft starters SVX, SPX variable frequency drives 9000X variable frequency drives: SVX, SPX Page 4 DS7 soft starters PowerXL™ DC1, DA1 variable frequency drives S801+, S811+ soft starters Table of contents Energizing a world that demands more. Discover today’s Eaton. Powering business worldwide As a global diversified power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses. Eaton’s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, efficiently, safely and sustainably. We provide integrated solutions that help make energy, in all its forms, We deliver: s more practical and Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable s Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power s accessible. With 2012 sales of $16.3 billion, Eaton has approximately 103,000 employees Aerospace solutions that make aircraft lighter, safer and less around the world and costly to operate, and help airports operate more efficiently sells products in more than 175 countries. s Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions Eaton’s electrical business Eaton is a global leader with expertise in: %ATON IS POSITIONED THROUGH ITS GLOBAL SOLUTIONS TO ANSWER TODAYS MOST CRITICAL ELECTRICAL POWER MANAGEMENT CHALLENGES 7ITH YEARS OF ELECTRICAL EXPERIENCE BEHIND US WERE ENERGIZED BY THE CHALLENGE OF POWERING UP A WORLD THAT DEMANDS TWICE AS MUCH ENERGY AS TODAY 7ERE ANTICIPATING NEEDS ENGINEERING PRODUCTS AND CREATING SOLUTIONS TO ENERGIZE OUR MARKETS TODAY AND IN THE FUTURE s 0OWER DISTRIBUTION AND CIRCUIT PROTECTION s "ACKUP POWER PROTECTION s 3OLUTIONS FOR HARSH AND HAZARDOUS ENVIRONMENTS s ,IGHTING AND SECURITY s 3TRUCTURAL SOLUTIONS AND WIRING DEVICES s #ONTROL AND AUTOMATION 7E ARE DEDICATED TO ENSURING THAT RELIABLE EFFICIENT AND SAFE POWER IS AVAILABLE WHEN ITS NEEDED MOST s %NGINEERING SERVICES www.eaton.eu PowerXL™ DC1, DA1 variable frequency drives Variable frequency drives make it possible to use infinitely variable speed control with three-phase asynchronous motors and AC motors. To do so, they convert a single-phase or three-phase alternating voltage with a specific frequency and amplitudes into a singlephase or three-phase alternating voltage with a variable frequency and a variable amplitude. With its DC1 and DA1 device series, Eaton has just the right variable frequency drive for any machine building application or standard electric drive system application, regardless of whether your needs are extremely simple or extremely complex. DC1 variable frequency drives Output voltage with sinusoidal pulse-width modulation (PWM) when using Volts-per-Hertz control (V/Hz control) with slip compensation and start voltage boost. DC1-12…: UIN 1~230 V/UOUT 3~230 V, allocated motor output 0.37 – 4 kW DC1-32…: UIN 3~230 V/UOUT 3~230 V, allocated motor output 0.37 – 4 kW DC1-34…: UIN 3~400 V/UOUT 3~400 V, allocated motor output 0.75 – 11 kW DC1-S2…: UIN 1~230 V/UOUT 1~230 V, allocated motor output 0.37 – 1.1 kW (Single-phase motor) DC1-S1…: UIN 1~115 V/UOUT 1~115 V, allocated motor output 0.37 – 0.55 kW DC1-1D…: UIN 1~115 V/UOUT 3~230 V, allocated motor output 0.37 – 1.1 kW (voltage doubler) DA1 variable frequency drives Output voltage with sinusoidal pulse-width modulation (PWM) when using Volts-per-Hertz control (V/Hz control), sensorless (SLVC) and sensored vector control DA1-12…: UIN 1~230 V/UOUT 3~230 V, allocated motor output 0.75 – 2.2 kW DA1-32…: UIN 3~230 V/UOUT 3~230 V, allocated motor output 0.75 – 75 kW DA1-34…: UIN 3~400 V/UOUT 3~400 V, allocated motor output 0.75 – 250 kW 5 System overview variable frequency drives DC1 6 Description variable frequency drives DC1 7 System overview variable frequency drives DA1 8 Description variable frequency drives DA1 9 Technical overview variable frequency drives DC1, DA1 10 Key to type references, Sizes and degree of protection UL/CSA variable frequency drives DC1 11 Ordering variable frequency drives DC1 14 Key to type references UL/CSA variable frequency drives DA1 18 Sizes and degree of protection variable frequency drives DA1 19 Ordering variable frequency drives DA1 20 Accessories 31 Braking resistances 34 Mains choke, motor chokes 36 Engineering Assigned switching and protective elements 39 General information on Engineering 40 Connection example for DC1 42 Assigned switching and protective elements 44 Technical data variable frequency drives DC1 48 variable frequency drives DA1 54 Mains choke, motor chokes 62 Dimensions variable frequency drives DC1 64 variable frequency drives DA1 65 Accessories 68 Mains choke, motor chokes 70 Sine filters 72 Braking resistances 74 CA04020001Z-EN-INT www.eaton.eu DC1, DA1 PowerXL™ variable frequency drives 6 PowerXL™ variable frequency drives DC1 System overview DC1 DC1 with IP20 degree of protection 1 7 2 6 3 5 4 DC1 variable frequency drive 1 → page 12 Mains choke, motor choke, sine filter 2 → page 36, → page 37 3 Braking resistance → page 34 Expansion modules 4 → page 33 5 SmartWire-DT module → page 33 Bluetooth communications stick 6 → page 31 External Keypad 7 → page 31 CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 7 DC1 Description DC1, DA1 DC1 The DC1 is Eaton's compact variable frequency drive. It has been specifically designed for simple applications. With only 14 basic parameters and outstanding ease of mounting and installation, the DC1 is perfect for quick commissioning. This makes these compact variable frequency drive ideal for series production applications in the field of machine building. Typical applications for this series include fans, pumps, and conveyor systems. In addition, additional parameters and functionalities can be flexibly enabled in order to allow the DC1 to handle more demanding applications as well. When configured with an IP66 degree of protection, DC1 variable frequency drives can be installed in humid and wet locations as well. In addition, these variable frequency drives can also be used as stand-alone units directly on site if they are equipped with a setpoint potentiometer, a selector switch, and a mains transfer switch and are configured with an IP66 degree of protection. Essential features Accessory consideration • Fast commissioning with 14 basic parameters • Performance range (allocated motor output) – 0.37 - 4 kW (UIN: 1~ 230 V / UOUT: 3~ 230 V) – 0.37 - 4 kW (UIN: 3~ 230 V / UOUT: 3~ 230 V) – 0.75 - 11 kW (UIN: 3~ 400 V / UOUT: 3~ 400 V), up to 7.5 kW at IP66 – 0.37 - 1.1 kW (UIN: 1~230 V / UOUT: 1~230 V), single-phase motor – 0.37 - 0.55 kW (UIN: 1~ 115 V / UOUT: 1~ 115 V), single-phase motor – 0.37 - 1.1 kW (UIN: 1~ 115 V / UOUT: 3~ 230 V) with voltage doubler • Large overload capability: 150% for 60 seconds, 175% for 2 seconds • Maximum ambient temperature: 50 °C without derating (IP20) / 40 °C (IP66) • Integrated® CANopen and Modbus • Degree of protection to IP20 and IP66 • EMC filter • Optional internal braking transistor for IP20 degree of protection • Integrated PI controller • V/Hz control with start voltage boost and slip compensation • International standards (CE, UL, cUL, C-Tick, UkrSEPRO, RoHS) • Side-by-side mounting • • • • • • • SmartWire-DT field bus module I/O expansion with plug-in modules External keypad for control panel door Mains choke Motor choke sine filter braking resistances CA04020001Z-EN-INT www.eaton.eu 8 PowerXL™ variable frequency drives DA1 System overview DA1 DA1 with IP20 degree of protection 1 2 6 5 3 4 DA1 variable frequency drives 1 → page 20 Mains choke, motor choke, sine filter 2 → page 36, → page 37 3 Braking resistance → page 34 4 Fieldbus modules → page 33 Bluetooth communications stick 5 → page 31 6 External Keypad → page 31 CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 9 DA1 Description DC1, DA1 DA1 DA1 frequency inverters are ideal for demanding, speed-dependent applications. Their wide performance range of up to 250 kW, together with their compact dimensions and high level of functionality, are sure to leave a lasting impression. Accordingly, DA1 units come with an integrated EMC filter and braking transistor. Moreover, the Modbus RTU and CANopen protocols are integrated as standard.®. With sensorless vector control, DA1 variable frequency drives are able to provide 200% torque at zero rpm. This makes them the perfect choice for applications that involve lifting or tractive forces. Comprehensive expansions such as additional inputs and outputs (analog, digital) and various field bus modules round off this variable frequency drive's flexibility. When configured with an IP66 degree of protection, DA1 variable frequency drives can be installed in humid and wet locations as well. In addition, these variable frequency drives can also be used as stand-alone units directly on site if they are equipped with a setpoint potentiometer, a selector switch, and a mains transfer switch. Essential features Accessory consideration • Performance range: – 0.75 - 2.2 kW (UIN: 1~ 230 V / UOUT: 3~ 230 V) – 0.75 - 75 kW (UIN: 3~ 230 V / UOUT: 3~ 230 V) – 0.75 - 250 kW (UIN: 3~ 400 V / UOUT: 3~ 400 V) • Large overload capability: 150% for 60 seconds, 200% for 4 seconds • Degrees of protection – IP20 to 11 kW at 400 V – IP40 at 200/250 kW at 400 V – IP55 for 11 to 160 kW with 400 V – IP66 up to 7.5 kW with 400 V; 0.75–4 kW with 230 V • The maximum allocated motor output is 7.5 kW with degree of protection IP66. • Integrated® CANopen and Modbus • EMC filter, integrated • Braking transistor, integrated • Control method: V/Hz control, sensorless vector control, vector control with encoder • Safe Torque Off (STO) • Can be used to drive high-efficiency PM motors • International standards (CE, UL, cUL, C-Tick, UkrSEPRO, RoHS) • Side-by-side mounting • Ambient air temperature 50 °C without derating (IP20), max. 40 °C (IP66) • Master/Slave functionality • SmartWire-DT field bus module • Field bus modules (PROFIBUS, PROFINET, Ethernet/IP, EtherCat, Modbus TCP, BACnet, and DeviceNet) • I/O expansion with plug-in modules • External keypad for control panel door • High-resolution OLED display • Mains choke • Motor chokes • sine filter • braking resistances CA04020001Z-EN-INT www.eaton.eu 10 PowerXL™ variable frequency drives DC1, DA1 Technical overview DC1, DA1 DC1... DA1... 115 V AC, single-phase ✓ - 230 V AC, 1-phase ✓ ✓ 230 V AC, 3-phase ✓ ✓ 400 V AC, 3-phase ✓ ✓ Rated operational voltage Ue Supply frequency fLN Hz 50/60 50/60 Rated operational current Ie A 2.3 - 24 2.2 - 450 Overload current for 60 s every 600 s IL % 150 150 Starting current for 2 s IL % 175 - Starting current for 4 s IL % - 200 Assigned motor rating at 115 V, 50 Hz P kW 0.37 - 0.55 (Single-phase motors) - at 230 V, 50 Hz P kW 0.37 - 4 (0.37 - 4 for single-phase motors) 0.75 - 75 at 400 V, 50 Hz P kW 0.75 - 11 0.75 - 250 IP20/NEMA 0 -10 - +50 -10 - +50 IP40 - -10 - +30 IP55/NEMA 3 - -10 - +40 / -10 - +30 (Ie > 180 A) IP66/NEMA 4X -10 - +40 -10 - +40 -40 - +60 -40 - +60 Ambient temperature Operation °C Storage °C Operation Mode U/f control ✓ ✓ Slip compensation ✓ ✓ sensorless vector control (SLV) - ✓ Vector control with feedback (CLV) - ✓ 4 - 32 4 - 32 Switching frequency fPWM Output voltage with Ve U2 kHz 115 V AC, single-phase ✓ - 230 V AC, single-phase ✓ - 230 V AC, 3-phase ✓ ✓ 400 V AC, 3-phase ✓ ✓ 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) Output Frequency f2 Hz Protection type IP20/NEMA 0 ✓ ✓ IP40 - ✓ IP55/NEMA 3 - ✓ IP66/NEMA 4X ✓ ✓ Fitted with Radio interference suppression filter ✓ ✓ Brake chopper ✓ ✓ Additional PCB protection - ✓ 7-digital display assembly ✓ ✓ OLED display - ✓ Interface OP-Bus (RS485)/Modbus RTU, CANopen® OP-Bus (RS485)/Modbus RTU, CANopen® Fieldbus connection SmartWire-DT Analog inputs parameterizable, max. 2 x (0 - 10 V, 0/4 - 20 mA) Ethernet IP DeviceNet PROFIBUS PROFINET Modbus-TCP EtherCAT BACnet/IP SmartWire-DT parameterizable, max. 2 x (0 - 10 V, 0/4 - 20 mA) Analog outputs parameterizable, max. 1 x (0 - 10 V) parameterizable, max. 2 x (0 - 10 V, 0/4 - 20 mA) Digital inputs parameterizable, max. 4 x (max. 30 V DC) parameterizable, 3 x (max. 30 V DC) Digital outputs parameterizable, max. 1 x (24 V DC) parameterizable, max. 2 x (24 V DC) Relay outputs Production quality parameterizable, 1 x N/O, 6 A (250 V AC) / 5 A (30 V DC) RoHS, ISO 9001 parameterizable, 1 x N/O and 1 x changeover contact, 6 A (250 V AC) / 5 A (30 V DC) RoHS, ISO 9001 Safety functions - STO (Safe Torque Off) Standards EMC: EN 61800-3:2004+A1-2012 EMC: EN 61800-3:2004+A1-2012 Certifications CE, cUL, UL, c-Tick, Ukr Sepro CE, cUL, UL, c-Tick, Ukr Sepro CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 11 DC1 Key to type references DC1, DA1 DC1 DC1 - 1 2 4D1 F N - A 20 N Device series Type DC1 = variable frequency drive, compact, series 1 (D = Drives, C = Compact, 1 = Series 1) N = Standard basic device Degree of protection Connection in power section 20 = IP20/NEMA 0 66 = IP66/NEMA 4X 6S = IP66 with switch/NEMA 4X, switched 1 = single-phase mains connection/ three-phase motor connection 3 = three-phase mains connection/ three-phase motor connection S = single-phase mains connection/ single-phase motor connection Display unit (display) A = LED display Mains voltage category 1 = 110 V (110 - 115 V ± 10 %) 2 = 230 V (200 - 240 V ± 10 %) 4 = 400 V (380 - 480 V ± 10 %) D = 110 V input/230 V output (voltage doubler) B = Brake chopper N = no internal brake chopper B = Brake chopper EMC (radio interference suppression filter) Rated operational current (examples) N = no internal RFI filter F = Internal RFI filter 2D2 = 2,2 A 4D1 = 4,1 A 024 = 24 A Sizes and degree of protection DC1 Frame size UL/CSA Protection type IP20/NEMA 0 Information relevant for export to North America IP66/NEMA 4X IP66/NEMA 4X Local controls FS1 Product Standards ⏚ L1/L L2/N L3 UL File No. UL Category Control No. CSA File No. 0 REV FWD OFF PWR ON 1 2 3 4 5 6 7 ⏚ 8 CSA Class No. North America Certification 9 10 11 U V W Suitable for Max. Voltage Rating FS2 ⏚ DC- L1/L L2/N L3 REV 0 FWD PWR OFF ON 1 ⏚ 2 3 4 5 6 DC+ BR 7 8 U UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking E172143 NMMS, NMMS7 UL report applies to both US and Canada 3211-06 UL listed, certified by UL for use in Canada Branch circuits 1~ 120 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) 1~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) 3~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) 3~ 480 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) 9 10 11 V W FS3 ⏚ DC- L1/L L2/N L3 REV 0 FWD PWR OFF ON 1 ⏚ DC+ BR 2 3 4 5 U 6 7 V 8 9 10 11 W CA04020001Z-EN-INT www.eaton.eu 12 PowerXL™ variable frequency drives DC1, for AC motors 115 V/230 V Ordering Rated motor current Fitted with P Ie A kW A Mains voltage (50/60Hz) ULN 110 (-10%) - 115 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 7 0.37 7 - - ✓ - - - ✓ - - - ✓ ✓ - ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ - ✓ - - - ✓ - - - ✓ ✓ ✓ - ✓ - ✓ - ✓ ✓ - - ✓ - ✓ - ✓ - - - ✓ - - - ✓ ✓ ✓ - ✓ - ✓ - ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ Brake chopper Local controls Assigned motor rating 2) 7-digital display assembly Rated operational current1) Ie Radio interference suppression filter DC1, for AC motors 115 V/230 V Frame size Protection type Part no. Article no. FS1 IP20/NEMA 0 DC1-S17D0NN-A20N 169497 DC1-S17D0NN-A66N 169498 DC1-S17D0NN-A6SN 169499 Price see price list Std. pack Ue 115 V AC, single-phase / U2 115 V AC, single-phase 10.5 0.55 10.5 IP66/NEMA 4X FS2 IP20/NEMA 0 IP66/NEMA 4X 1 off DC1-S1011NB-A20N 169500 DC1-S1011NB-A66N 169501 DC1-S1011NB-A6SN 169502 Ue 230 V AC, 1-phase / U2 230 V AC, single-phase Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 4.3 0.37 4.3 - 7 10.5 Notes 0.75 7 1.1 10.5 1) Rated FS1 FS2 IP20/NEMA 0 DC1-S24D3NN-A20N 169512 DC1-S24D3FN-A20N 169521 IP66/NEMA 4X DC1-S24D3NN-A66N 169513 DC1-S24D3NN-A6SN 169514 DC1-S24D3FN-A66N 169522 DC1-S24D3FN-A6SN 169523 IP20/NEMA 0 DC1-S27D0NN-A20N 169515 DC1-S27D0FN-A20N 169524 IP66/NEMA 4X DC1-S27D0NN-A66N 169516 DC1-S27D0NN-A6SN 169517 DC1-S27D0FN-A66N 169525 DC1-S27D0FN-A6SN 169526 IP20/NEMA 0 DC1-S2011NB-A20N 169518 DC1-S2011FB-A20N 169527 IP66/NEMA 4X DC1-S2011NB-A66N 169519 DC1-S2011NB-A6SN 169520 DC1-S2011FB-A66N 169528 DC1-S2011FB-A6SN 169529 1 off operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 11 CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 13 DC1, for three-phase motors 230 V P Ie A kW A Frame size Protection type Part no. Article no. FS1 IP20/NEMA 0 DC1-1D2D3NN-A20N 169503 DC1-1D2D3NN-A66N 169504 DC1-1D2D3NN-A6SN 169505 Mains voltage (50/60Hz) ULN 110 (-10%) - 115 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 2.3 0.37 2 - - ✓ - - - ✓ - - - ✓ ✓ - - ✓ - IP20/NEMA 0 - - ✓ - IP66/NEMA 4X - - ✓ ✓ - ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ - ✓ - - - ✓ - - - ✓ ✓ ✓ - ✓ - ✓ - ✓ ✓ - - ✓ - ✓ - ✓ - - - ✓ - - - ✓ ✓ ✓ - ✓ - ✓ - ✓ ✓ Price see price list Std. pack DC1, DA1 Fitted with Local controls Rated motor current 7-digital display assembly Assigned motor rating 2) Brake chopper Rated operational current1) Ie Radio interference suppression filter DC1, for three-phase motors 230 V Ue 115 V AC, single-phase / U2 230 V AC, 3-phase 4.3 5.8 0.75 1.1 3.2 4.6 IP66/NEMA 4X FS2 IP20/NEMA 0 IP66/NEMA 4X 1 off DC1-1D4D3NN-A20N 169506 DC1-1D4D3NN-A66N 169507 DC1-1D4D3NN-A6SN 169508 DC1-1D5D8NB-A20N 169509 DC1-1D5D8NB-A66N 169510 DC1-1D5D8NB-A6SN 169511 Ue 230 V AC, 1-phase / U2 230 V AC, 3-phase Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 2.3 0.37 2 - 4.3 Notes 0.75 1) Rated 3.2 FS1 FS1 IP20/NEMA 0 DC1-122D3NN-A20N 169222 DC1-122D3FN-A20N 169240 IP66/NEMA 4X DC1-122D3NN-A66N 169223 DC1-122D3NN-A6SN 169224 DC1-122D3FN-A66N 169241 DC1-122D3FN-A6SN 169242 IP20/NEMA 0 DC1-124D3NN-A20N 169225 DC1-124D3FN-A20N 169243 IP66/NEMA 4X DC1-124D3NN-A66N 169226 DC1-124D3NN-A6SN 169227 DC1-124D3FN-A66N 169244 DC1-124D3FN-A6SN 169245 1 off operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 11 CA04020001Z-EN-INT www.eaton.eu 14 PowerXL™ variable frequency drives Fitted with P Ie A kW A Local controls Rated motor current 7-digital display assembly Assigned motor rating 2) Brake chopper Rated operational current1) Ie Radio interference suppression filter DC1, for three-phase motors 230 V - ✓ - ✓ - ✓ - - ✓ ✓ - ✓ ✓ ✓ - - - ✓ - - - ✓ ✓ ✓ - ✓ - ✓ - ✓ ✓ - ✓ ✓ - - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ Frame size Protection type Part no. Article no. FS1 IP20/NEMA 0 DC1-127D0NN-A20N 169228 DC1-127D0FN-A20N 169246 Price see price list Std. pack Ue 230 V AC, 1-phase / U2 230 V AC, 3-phase Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 7 1.5 6.3 - 10.5 15 Notes 2.2 8.7 4 14.8 1) Rated DC1-127D0NB-A20N 169231 DC1-127D0FB-A20N 169249 FS2 FS1 IP66/NEMA 4X FS3 DC1-127D0NN-A66N 169229 DC1-127D0NN-A6SN 169230 DC1-127D0FN-A66N 169247 DC1-127D0FN-A6SN 169248 DC1-127D0NB-A66N 169232 DC1-127D0NB-A6SN 169233 DC1-127D0FB-A66N 169250 DC1-127D0FB-A6SN 169251 FS2 FS2 1 off IP20/NEMA 0 DC1-12011NB-A20N 169234 DC1-12011FB-A20N 169252 IP66/NEMA 4X DC1-12011NB-A66N 169235 DC1-12011NB-A6SN 169236 DC1-12011FB-A66N 169253 DC1-12011FB-A6SN 169254 IP20/NEMA 0 DC1-12015NB-A20N 169237 DC1-12015NB-A66N 169238 DC1-12015NB-A6SN 169239 IP66/NEMA 4X operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 11 CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 15 DC1, for three-phase motors 230 V P Ie A kW A Frame size Protection type Part no. Article no. FS1 IP20/NEMA 0 DC1-322D3NN-A20N 169255 DC1-322D3NN-A66N 169256 DC1-322D3NN-A6SN 169257 Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 2.3 0.37 2 - - ✓ - - - ✓ - - - ✓ ✓ - - ✓ - IP20/NEMA 0 - - ✓ - IP66/NEMA 4X - - ✓ ✓ - - ✓ - FS1 - ✓ ✓ - FS2 ✓ ✓ ✓ - - - ✓ - - - ✓ ✓ - ✓ ✓ - - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ Price see price list Std. pack DC1, DA1 Fitted with Local controls Rated motor current 7-digital display assembly Assigned motor rating 2) Brake chopper Rated operational current1) Ie Radio interference suppression filter DC1, for three-phase motors 230 V Ue 230 V AC, 3-phase / U2 230 V AC, 3-phase 4.3 7 10.5 18 Notes 0.75 1.5 2.2 4 3.2 6.3 8.7 14.8 1) Rated IP66/NEMA 4X FS1 FS3 DC1-324D3NN-A20N 169258 DC1-324D3NN-A66N 169259 DC1-324D3NN-A6SN 169260 IP20/NEMA 0 DC1-327D0NN-A20N 169261 DC1-327D0NB-A20N 169264 DC1-327D0FB-A20N 169444 IP66/NEMA 4X DC1-327D0NN-A66N 169262 DC1-327D0NN-A6SN 169263 DC1-327D0NB-A66N 169436 DC1-327D0NB-A6SN 169437 DC1-327D0FB-A66N 169445 DC1-327D0FB-A6SN 169446 FS2 FS2 1 off IP20/NEMA 0 DC1-32011NB-A20N 169438 DC1-32011FB-A20N 169447 IP66/NEMA 4X DC1-32011NB-A66N 169439 DC1-32011NB-A6SN 169440 DC1-32011FB-A66N 169448 DC1-32011FB-A6SN 169449 IP20/NEMA 0 DC1-32018NB-A20N 169441 DC1-32018FB-A20N 169450 IP66/NEMA 4X DC1-32018NB-A66N 169442 DC1-32018NB-A6SN 169443 DC1-32018FB-A66N 169451 DC1-32018FB-A6SN 169452 operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 11 CA04020001Z-EN-INT www.eaton.eu 16 PowerXL™ variable frequency drives DC1, for three-phase motors 400 V Fitted with P Ie A kW A Local controls Rated motor current 7-digital display assembly Assigned motor rating 2) Brake chopper Rated operational current1) Ie Radio interference suppression filter DC1, for three-phase motors 400 V - ✓ - ✓ - ✓ - - - ✓ - - - ✓ ✓ ✓ - ✓ - ✓ - ✓ ✓ - - ✓ - ✓ - ✓ - - ✓ ✓ - ✓ ✓ ✓ - - - ✓ - - - ✓ ✓ ✓ - ✓ - - ✓ ✓ - - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ Frame size Protection type Part no. Article no. FS1 IP20/NEMA 0 DC1-342D2NN-A20N 169453 DC1-342D2FN-A20N 169475 IP66/NEMA 4X DC1-342D2NN-A66N 169454 DC1-342D2NN-A6SN 169455 DC1-342D2FN-A66N 169476 DC1-342D2FN-A6SN 169477 FS1 IP20/NEMA 0 DC1-344D1NN-A20N 169456 DC1-344D1FN-A20N 169478 DC1-344D1NB-A20N 169459 DC1-344D1FB-A20N 169481 FS1 IP66/NEMA 4X DC1-344D1NN-A66N 169457 DC1-344D1NN-A6SN 169458 DC1-344D1FN-A66N 169479 Price see price list Std. pack Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 2.2 0.75 1.9 - 4.1 5.8 Notes 1.5 3.6 2.2 5 1) Rated FS2 DC1-344D1NB-A66N 169460 DC1-344D1NB-A6SN 169461 ✓ FS1 ✓ - FS2 ✓ ✓ ✓ DC1-344D1FN-A6SN 169480 DC1-344D1FB-A66N 169482 DC1-344D1FB-A6SN 169483 - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ FS2 IP20/NEMA 0 DC1-345D8NB-A20N 169462 DC1-345D8FB-A20N 169484 IP66/NEMA 4X DC1-345D8NB-A66N 169463 DC1-345D8NB-A6SN 169464 DC1-345D8FB-A66N 169485 DC1-345D8FB-A6SN 169486 1 off operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 11 CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 17 DC1, for three-phase motors 400 V P Ie A kW A Frame size Protection type Part no. Article no. FS2 IP20/NEMA 0 DC1-349D5NB-A20N 169465 DC1-349D5FB-A20N 169487 IP66/NEMA 4X DC1-349D5NB-A66N 169466 DC1-349D5NB-A6SN 169467 DC1-349D5FB-A66N 169488 DC1-349D5FB-A6SN 169489 IP20/NEMA 0 DC1-34014NB-A20N 169468 DC1-34014FB-A20N 169490 IP66/NEMA 4X DC1-34014NB-A66N 169469 DC1-34014NB-A6SN 169470 DC1-34014FB-A66N 169491 DC1-34014FB-A6SN 169492 IP20/NEMA 0 DC1-34018NB-A20N 169471 DC1-34018FB-A20N 169493 IP66/NEMA 4X DC1-34018NB-A66N 169472 DC1-34018NB-A6SN 169473 DC1-34018FB-A66N 169494 DC1-34018FB-A6SN 169495 DC1-34024NB-A20N 169474 DC1-34024FB-A20N 169496 ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ - - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ - IP20/NEMA 0 ✓ ✓ ✓ - IP20/NEMA 0 Price see price list Std. pack DC1, DA1 Fitted with Local controls Rated motor current 7-digital display assembly Assigned motor rating 2) Brake chopper Rated operational current1) Ie Radio interference suppression filter DC1, for three-phase motors 400 V Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 9.5 4 8.5 - 14 18 24 Notes 5.5 7.5 11 1) Rated 11.3 15.2 21.7 FS3 1 off operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 11 CA04020001Z-EN-INT www.eaton.eu 18 PowerXL™ variable frequency drives DA1 Key to type references DA1 DA1 - 1 2 4D3 F B - A 20 N Device series Type DA1 = variable frequency drive, compact, series 1 (D = Drives, A = Advanced, 1 = Series 1) N = Standard basic device C = coated printed circuit boards Connection in power section Degree of protection 1 = single-phase mains connection/ three-phase motor connection 3 = three-phase mains connection/ three-phase motor connection 20 = IP20/NEMA 0 40 = IP40 55 = IP55/NEMA 3 66 = IP66/NEMA 4X 6S = IP66 with switch/NEMA 4X, switched Mains voltage category 2 = 230 V (200 - 240 V ± 10 %) 4 = 400 V (380 - 480 V ± 10 %) Display unit (display) A = LED display B = OLED display Rated operational current (examples) Brake chopper 4D3 = 4,3 A 024 = 24 A 248 = 248 A N = no internal brake chopper B = Brake chopper EMC (radio interference suppression filter) N = no internal RFI filter F = Internal RFI filter UL/CSA Information relevant for export to North America Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Suitable for Max. Voltage Rating CA04020001Z-EN-INT UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking E172143 NMMS, NMMS7 UL report applies to both US and Canada 3211-06 UL listed, certified by UL for use in Canada Branch circuits 1~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) 3~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) 3~ 480 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) www.eaton.eu PowerXL™ variable frequency drives 19 DA1 Sizes and degree of protection Frame size Protection type IP20/NEMA 0 IP66/NEMA 4X DC1, DA1 DA1 IP66/NEMA 4X Local controls FS2 ⏚ DC- L1/L L2/N L3 0 REV FWD PWR OFF ON COM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ⏚ DC+ BR U 18 V W FS3 ⏚ DC- L1/L L2/N L3 0 REV FWD PWR OFF ON COM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ⏚ Frame size DC+ BR U V 18 W Protection type IP55/NEMA 3 IP40 FS4 - - FS5 - - Panel version - FS5 FS8 - CA04020001Z-EN-INT www.eaton.eu 20 PowerXL™ variable frequency drives DA1, for three-phase motors 230 V DA1, for three-phase motors 230 V Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly Rated motor current Ie Brake chopper Assigned motor rating 2) P Radio interference suppression filter Rated operational current1) Ie Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 4.3 0.75 3.2 ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ ✓ - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ ✓ - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ Frame size Protection type Part no. Article no. FS2 IP20/NEMA 0 DA1-124D3FB-A20N 169152 DA1-124D3FB-A20C 169078 IP66/NEMA 4X DA1-124D3FB-A66N 169153 DA1-124D3FB-B66N 169280 DA1-124D3FB-B66C 169347 DA1-124D3FB-A6SN 169154 DA1-124D3FB-B6SN 169281 DA1-124D3FB-A66C 169079 DA1-124D3FB-A6SC 169080 DA1-124D3FB-B6SC 169348 IP20/NEMA 0 DA1-127D0FB-A20N 169155 DA1-127D0FB-A20C 169081 IP66/NEMA 4X DA1-127D0FB-A66N 169156 DA1-127D0FB-B66N 169282 DA1-127D0FB-A66C 169082 DA1-127D0FB-B6SN 169283 DA1-127D0FB-B66C 169349 DA1-127D0FB-A6SN 169157 DA1-127D0FB-B6SC 169350 DA1-127D0FB-A6SC 169083 IP20/NEMA 0 DA1-12011FB-A20N 169158 DA1-12011FB-A20C 169084 IP66/NEMA 4X DA1-12011FB-A66N 169159 DA1-12011FB-B66N 169284 DA1-12011FB-A6SN 169160 DA1-12011FB-B6SN 169285 DA1-12011FB-B66C 169351 DA1-12011FB-A66C 169085 DA1-12011FB-B6SC 169352 DA1-12011FB-A6SC 169086 Price see price list Std. pack Ue 230 V AC, 1-phase / U2 230 V AC, 3-phase 7 10.5 Notes 1.5 2.2 1) Rated 6.3 8.7 FS2 FS2 1 off operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 18 CA04020001Z-EN-INT www.eaton.eu 2) Assigned PowerXL™ variable frequency drives 21 DA1, for three-phase motors 400 V DA1, for three-phase motors 400 V Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 4.3 0.75 3.2 ✓ ✓ ✓ - - - ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ - ✓ ✓ - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ - ✓ ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ Frame size Protection type Part no. Article no. FS2 IP20/NEMA 0 DA1-324D3FB-A20N 169161 DA1-324D3FB-A20C 169087 IP66/NEMA 4X DA1-324D3FB-A66N 169162 DA1-324D3FB-B66N 169286 DA1-324D3FB-B6SN 169287 DA1-324D3FB-B66C 169353 DA1-324D3FB-A6SN 169163 DA1-324D3FB-A66C 169088 DA1-324D3FB-B6SC 169354 DA1-324D3FB-A6SC 169089 IP20/NEMA 0 DA1-327D0FB-A20N 169164 DA1-327D0FB-A20C 169090 IP66/NEMA 4X DA1-327D0FB-A66N 169165 DA1-327D0FB-B66N 169288 DA1-327D0FB-A66C 169091 DA1-327D0FB-B66C 169355 DA1-327D0FB-A6SN 169166 DA1-327D0FB-B6SN 169289 DA1-327D0FB-B6SC 169356 DA1-327D0FB-A6SC 169092 IP20/NEMA 0 DA1-32011FB-A20N 169167 DA1-32011FB-A20C 169093 IP66/NEMA 4X DA1-32011FB-A66N 169168 DA1-32011FB-B66N 169290 DA1-32011FB-A6SN 169169 DA1-32011FB-B66C 169357 DA1-32011FB-B6SN 169291 DA1-32011FB-A66C 169094 DA1-32011FB-A6SC 169095 DA1-32011FB-B6SC 169358 Price see price list Std. pack DC1, DA1 Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly Rated motor current Ie Brake chopper Assigned motor rating 2) P Radio interference suppression filter Rated operational current1) Ie Ue 230 V AC, 3-phase / U2 230 V AC, 3-phase 7 10.5 Notes 1.5 2.2 1) Rated 6.3 8.7 FS2 FS2 1 off operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 18 CA04020001Z-EN-INT www.eaton.eu 2) Assigned 22 PowerXL™ variable frequency drives DA1, for three-phase motors 230 V DA1, for three-phase motors 230 V Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly P Rated motor current Ie Brake chopper Assigned motor rating 2) Radio interference suppression filter Rated operational current1) Ie Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 18 4 14.8 ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - - ✓ ✓ ✓ - - - ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ Frame size Protection type Part no. Article no. FS3 IP20/NEMA 0 DA1-32018FB-A20N 169170 DA1-32018FB-A20C 169096 IP66/NEMA 4X DA1-32018FB-B66N 169292 DA1-32018FB-A66N 169171 DA1-32018FB-A6SN 169172 DA1-32018FB-B6SN 169293 DA1-32018FB-A66C 169097 DA1-32018FB-B66C 169359 DA1-32018FB-A6SC 169098 DA1-32018FB-B6SC 169360 FS3 IP20/NEMA 0 DA1-32024FB-A20N 169173 DA1-32024FB-A20C 169099 FS4 IP55 DA1-32024FB-A55N 169174 DA1-32024FB-B55N 169294 DA1-32024FB-B55C 169361 DA1-32024FB-A55C 169100 FS4 IP55/NEMA 3 DA1-32039FB-A55N 169175 DA1-32039FB-B55N 169295 DA1-32039FB-B55C 169362 DA1-32039FB-A55C 169101 Price see price list Std. pack Ue 230 V AC, 3-phase / U2 230 V AC, 3-phase 24 39 46 61 Notes 5.5 19.6 7.5 26.5 11 38 15 51 1) Rated 1 off DA1-32046FB-A55N 169176 DA1-32046FB-B55N 169296 DA1-32046FB-B55C 169363 DA1-32046FB-A55C 169102 DA1-32061FB-A55N 169177 DA1-32061FB-B55N 169297 DA1-32061FB-B55C 169364 DA1-32061FB-A55C 169103 operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 18 2) Assigned CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 23 DA1, for three-phase motors 230 V DA1, for three-phase motors 230 V Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 72 18.5 63 ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ - - ✓ - - ✓ - ✓ - - - ✓ - ✓ - - ✓ ✓ ✓ - ✓ - - ✓ ✓ ✓ - - - ✓ - - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ - - ✓ - - ✓ - ✓ - - - ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ - - ✓ - ✓ ✓ - ✓ - - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ - - ✓ - - ✓ - ✓ - - - ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ - - ✓ - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ Frame size Protection type Part no. Article no. FS5 IP55/NEMA 3 DA1-32072FB-A55N 169178 DA1-32072FB-B55N 169298 DA1-32072FB-A55C 169104 DA1-32072FB-B55C 169365 Price see price list Std. pack DC1, DA1 Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly P Rated motor current Ie Brake chopper Assigned motor rating 2) Radio interference suppression filter Rated operational current1) Ie Ue 230 V AC, 3-phase / U2 230 V AC, 3-phase 90 110 150 Notes 22 30 453) 71 96 141 FS6 1 off DA1-32090FN-B55N 169299 DA1-32090FN-A55N 169179 DA1-32090FN-A55C 169105 DA1-32090FB-B55N 169300 DA1-32090FB-A55N 169180 DA1-32090FN-B55C 169366 DA1-32090FB-A55C 169106 DA1-32090FB-B55C 169367 DA1-32110FN-B55N 169301 DA1-32110FN-A55N 169181 DA1-32110FB-A55N 169182 DA1-32110FB-B55N 169302 DA1-32110FN-B55C 169368 DA1-32110FN-A55C 169107 DA1-32110FB-A55C 169108 DA1-32110FB-B55C 169369 DA1-32150FN-B55N 169303 DA1-32150FN-A55N 169183 DA1-32150FB-A55N 169184 DA1-32150FB-B55N 169304 DA1-32150FN-B55C 169370 DA1-32150FN-A55C 169109 DA1-32150FB-B55C 169371 DA1-32150FB-A55C 169110 1) Rated operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) 3) Alternatively: allocated motor output of 37 kW (230 V) with 117-A rated motor current Information relevant for export to North America → page 18 2) Assigned CA04020001Z-EN-INT www.eaton.eu 24 PowerXL™ variable frequency drives DA1, for three-phase motors 230 V DA1, for three-phase motors 230 V Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly P Rated motor current Ie Brake chopper Assigned motor rating 2) Radio interference suppression filter Rated operational current1) Ie Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 180 553) 173 ✓ - - ✓ - - ✓ - ✓ - - - ✓ ✓ ✓ - - - ✓ - ✓ - - ✓ ✓ - - ✓ - ✓ ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ - - ✓ - - ✓ - ✓ - - - ✓ ✓ ✓ - - - ✓ - ✓ - - ✓ ✓ ✓ - ✓ - - ✓ - - ✓ - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ - - ✓ - - ✓ - ✓ - - - ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ - - ✓ - ✓ ✓ - ✓ - - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ Frame size Protection type Part no. Article no. FS6 IP55 DA1-32180FN-B55N 169305 DA1-32180FN-A55N 169185 DA1-32180FB-A55N 169186 DA1-32180FN-A55C 169111 DA1-32180FN-B55C 169372 DA1-32180FB-B55N 169306 DA1-32180FB-B55C 169373 DA1-32180FB-A55C 169112 Price see price list Std. pack Ue 230 V AC, 3-phase / U2 230 V AC, 3-phase 202 248 Notes 55 173 75 233 1) Rated FS7 1 off DA1-32202FN-B55N 169307 DA1-32202FN-A55N 169187 DA1-32202FB-A55N 169188 DA1-32202FN-A55C 169113 DA1-32202FB-B55N 169308 DA1-32202FN-B55C 169374 DA1-32202FB-B55C 169375 DA1-32202FB-A55C 169114 DA1-32248FN-B55N 169309 DA1-32248FN-A55N 169189 DA1-32248FB-A55N 169190 DA1-32248FB-B55N 169310 DA1-32248FN-B55C 169376 DA1-32248FN-A55C 169115 DA1-32248FB-A55C 169116 DA1-32248FB-B55C 169377 operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) 3) Alternatively: allocated motor output of 45 kW (230 V) with 141-A rated motor current Information relevant for export to North America → page 18 2) Assigned CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 25 DA1, for three-phase motors 400 V DA1, for three-phase motors 400 V Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 2.2 0.75 1.9 ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ ✓ - ✓ ✓ - ✓ - ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ - ✓ ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - ✓ ✓ Frame size Protection type Part no. Article no. FS2 IP20/NEMA 0 DA1-342D2FB-A20N 169191 DA1-342D2FB-A20C 169117 IP66/NEMA 4X DA1-342D2FB-A66N 169192 DA1-342D2FB-B66N 169311 DA1-342D2FB-A6SN 169193 DA1-342D2FB-A66C 169118 DA1-342D2FB-B6SN 169312 DA1-342D2FB-B66C 169378 DA1-342D2FB-B6SC 169379 DA1-342D2FB-A6SC 169119 IP20/NEMA 0 DA1-344D1FB-A20N 169194 DA1-344D1FB-A20C 169120 IP66/NEMA 4X DA1-344D1FB-A66N 169195 DA1-344D1FB-B66N 169313 DA1-344D1FB-A6SN 169196 DA1-344D1FB-B6SN 169314 DA1-344D1FB-A66C 169049 DA1-344D1FB-B66C 169380 DA1-344D1FB-B6SC 169381 DA1-344D1FB-A6SC 169050 IP20/NEMA 0 DA1-345D8FB-A20N 169197 DA1-345D8FB-A20C 169051 IP66/NEMA 4X DA1-345D8FB-A66N 169198 DA1-345D8FB-B66N 169315 DA1-345D8FB-A6SN 169199 DA1-345D8FB-B66C 169382 DA1-345D8FB-B6SN 169316 DA1-345D8FB-A66C 169052 DA1-345D8FB-B6SC 169383 DA1-345D8FB-A6SC 169053 Price see price list Std. pack DC1, DA1 Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly Rated motor current Ie Brake chopper Assigned motor rating 2) P Radio interference suppression filter Rated operational current1) Ie Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase 4.1 5.8 Notes 1.5 2.2 1) Rated 3.6 5 FS2 FS2 1 off operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 18 CA04020001Z-EN-INT www.eaton.eu 2) Assigned 26 PowerXL™ variable frequency drives DA1, for three-phase motors 400 V DA1, for three-phase motors 400 V Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly Rated motor current Ie Brake chopper Assigned motor rating 2) P Radio interference s uppression filter Rated operational current1) Ie Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 9.5 4 8.5 ✓ ✓ ✓ - - - ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ ✓ - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ - - - ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ - - ✓ ✓ ✓ - - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ ✓ - ✓ ✓ ✓ Frame size Protection type Part no. Article no. FS2 IP20/NEMA 0 DA1-349D5FB-A20N 169200 DA1-349D5FB-A20C 169054 IP66/NEMA 4X DA1-349D5FB-A66N 169201 DA1-349D5FB-B66N 169317 DA1-349D5FB-A66C 169055 DA1-349D5FB-B6SN 169318 DA1-349D5FB-A6SN 169202 DA1-349D5FB-B66C 169384 DA1-349D5FB-A6SC 169056 DA1-349D5FB-B6SC 169385 IP20/NEMA 0 DA1-34014FB-A20N 169203 DA1-34014FB-A20C 169057 IP66/NEMA 4X DA1-34014FB-A66N 169204 DA1-34014FB-B66N 169319 DA1-34014FB-A6SN 169205 DA1-34014FB-B6SN 169320 DA1-34014FB-B66C 169386 DA1-34014FB-A66C 169058 DA1-34014FB-A6SC 169059 DA1-34014FB-B6SC 169387 IP20/NEMA 0 DA1-34018FB-A20N 169206 DA1-34018FB-A20C 169060 IP66/NEMA 4X DA1-34018FB-B66N 169321 DA1-34018FB-A66N 169207 DA1-34018FB-B66C 169388 DA1-34018FB-A6SN 169208 DA1-34018FB-B6SN 169322 DA1-34018FB-A66C 169061 DA1-34018FB-A6SC 169062 DA1-34018FB-B6SC 169389 Price see price list Std. pack Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase 14 18 Notes 5.5 7.5 1) Rated 11.3 15.2 FS3 FS3 1 off operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 18 CA04020001Z-EN-INT www.eaton.eu 2) Assigned PowerXL™ variable frequency drives 27 DA1, for three-phase motors 400 V DA1, for three-phase motors 400 V Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 24 11 21.7 ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - - ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ - ✓ - - ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ Frame size Protection type Part no. Article no. FS3 IP20/NEMA 0 DA1-34024FB-A20N 169209 DA1-34024FB-A20C 169063 FS4 IP55 DA1-34024FB-A55N 169210 DA1-34024FB-B55N 169323 DA1-34024FB-B55C 169390 DA1-34024FB-A55C 169064 Price see price list Std. pack DC1, DA1 Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly P Rated motor current Ie Brake chopper Assigned motor rating 2) Radio interference suppression filter Rated operational current1) Ie Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase 30 39 46 61 72 Notes 15 18.5 22 30 37 29.3 36 41 55 68 1 off DA1-34030FB-B55N 169324 DA1-34030FB-A55N 169211 DA1-34030FB-A55C 169065 DA1-34030FB-B55C 169391 DA1-34039FB-B55N 169325 DA1-34039FB-A55N 169212 DA1-34039FB-A55C 169066 DA1-34039FB-B55C 169392 DA1-34046FB-A55N 169213 DA1-34046FB-B55N 169326 DA1-34046FB-B55C 169393 DA1-34046FB-A55C 169067 FS5 DA1-34061FB-A55N 169214 DA1-34061FB-B55N 169327 DA1-34061FB-A55C 169068 DA1-34061FB-B55C 169394 DA1-34072FB-A55N 169215 DA1-34072FB-B55N 169328 DA1-34072FB-A55C 169069 DA1-34072FB-B55C 169395 1) Rated operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 18 2) Assigned CA04020001Z-EN-INT www.eaton.eu 28 PowerXL™ variable frequency drives DA1, for three-phase motors 400 V DA1, for three-phase motors 400 V Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly P Rated motor current Ie Brake chopper Assigned motor rating 2) Radio interference suppression filter Rated operational current1) Ie Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 90 45 81 ✓ - ✓ - - - ✓ - - ✓ - - ✓ ✓ ✓ - - - ✓ - ✓ - - ✓ ✓ ✓ - ✓ - - ✓ - - ✓ - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ - ✓ - - - ✓ - - ✓ - - ✓ ✓ ✓ - - - ✓ - ✓ - - ✓ ✓ - - ✓ - ✓ ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ - - ✓ - - ✓ - ✓ - - - ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ - - ✓ - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ Frame size Protection type Part no. Article no. FS6 IP55/NEMA 3 DA1-34090FN-A55N 169216 DA1-34090FN-B55N 169329 DA1-34090FB-A55N 169037 DA1-34090FN-A55C 169070 DA1-34090FB-B55N 169330 DA1-34090FN-B55C 169396 DA1-34090FB-B55C 169397 DA1-34090FB-A55C 169071 Price see price list Std. pack Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase 110 150 Notes 55 99 75 134 1) Rated 1 off DA1-34110FN-A55N 169038 DA1-34110FN-B55N 169331 DA1-34110FB-A55N 169039 DA1-34110FN-A55C 169072 DA1-34110FN-B55C 169398 DA1-34110FB-B55N 169332 DA1-34110FB-B55C 169399 DA1-34110FB-A55C 169265 DA1-34150FN-B55N 169333 DA1-34150FN-A55N 169040 DA1-34150FB-A55N 169041 DA1-34150FB-B55N 169334 DA1-34150FN-B55C 169400 DA1-34150FN-A55C 169266 DA1-34150FB-B55C 169401 DA1-34150FB-A55C 169267 operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 18 2) Assigned CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 29 DA1, for three-phase motors 400 V DA1, for three-phase motors 400 V Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 180 90 161 ✓ - ✓ - - - ✓ - - ✓ - - ✓ - ✓ - - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ - - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ - ✓ - - - ✓ - - ✓ - - ✓ ✓ ✓ - - - ✓ - - ✓ - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ - - ✓ - - ✓ - ✓ - - - ✓ - ✓ - - ✓ ✓ - - ✓ - ✓ ✓ ✓ - ✓ - - ✓ ✓ ✓ - - - ✓ ✓ ✓ - - ✓ ✓ ✓ - ✓ - ✓ Frame size Protection type Part no. Article no. FS6 IP55 DA1-34180FN-A55N 169042 DA1-34180FN-B55N 169335 DA1-34180FN-A55C 169268 DA1-34180FB-A55N 169043 DA1-34180FB-B55N 169336 DA1-34180FN-B55C 169402 DA1-34180FB-A55C 169269 DA1-34180FB-B55C 169403 Price see price list Std. pack DC1, DA1 Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly P Rated motor current Ie Brake chopper Assigned motor rating 2) Radio interference suppression filter Rated operational current1) Ie Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase 202 240 Notes 110 132 196 231 FS7 1 off DA1-34202FN-A55N 169044 DA1-34202FN-B55N 169337 DA1-34202FB-A55N 169045 DA1-34202FN-B55C 169404 DA1-34202FN-A55C 169270 DA1-34202FB-B55N 169338 DA1-34202FB-B55C 169405 DA1-34202FB-A55C 169271 DA1-34240FN-B55N 169339 DA1-34240FN-A55N 169046 DA1-34240FN-A55C 169272 DA1-34240FN-B55C 169406 DA1-34240FB-B55N 169340 DA1-34240FB-A55N 169047 DA1-34240FB-A55C 169273 DA1-34240FB-B55C 169407 1) Rated operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 18 2) Assigned CA04020001Z-EN-INT www.eaton.eu 30 PowerXL™ variable frequency drives DA1, for three-phase motors 400 V DA1, for three-phase motors 400 V Additional PCB protection A Local controls kW OLED display A Fitted with 7-digital display assembly P Rated motor current Ie Brake chopper Assigned motor rating 2) Radio interference suppression filter Rated operational current1) Ie - - ✓ - ✓ ✓ - - ✓ - - ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ - - ✓ ✓ - - ✓ - - ✓ - ✓ - - - ✓ - - ✓ - ✓ ✓ ✓ ✓ - - - ✓ - ✓ - - ✓ ✓ ✓ - ✓ - - ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ ✓ - - ✓ - - ✓ - ✓ - - - ✓ ✓ - ✓ - - ✓ ✓ ✓ - - - ✓ - - ✓ - ✓ ✓ - ✓ - - ✓ ✓ ✓ - ✓ - ✓ ✓ ✓ ✓ - - ✓ Frame size Protection type Part no. Article no. Price see price list FS7 IP55 DA1-34302FN-B55C 169408 DA1-34302FN-B55N 169341 DA1-34302FN-A55C 169274 DA1-34302FB-B55C 169217 DA1-34302FB-A55N 169073 DA1-34302FB-B55N 169342 DA1-34302FN-A55N 169048 DA1-34302FB-A55C 169275 1 off FS8 IP40 DA1-34370FN-B40N 169343 DA1-34370FN-A40N 169074 DA1-34370FN-B40C 169218 DA1-34370FB-A40N 169075 DA1-34370FN-A40C 169276 DA1-34370FB-B40N 169344 DA1-34370FB-B40C 169219 DA1-34370FB-A40C 169277 1 off Std. pack Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V Interface OP-Bus (RS485)/Modbus RTU, CANopen® 302 160 279 - 370 450 Notes 200 349 250 437 1) Rated DA1-34450FN-B40N 169345 DA1-34450FN-A40N 169076 DA1-34450FB-B40N 169346 DA1-34450FB-A40N 169077 DA1-34450FN-B40C 169220 DA1-34450FN-A40C 169278 DA1-34450FB-B40C 169221 DA1-34450FB-A40C 169279 operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → page 18 2) Assigned CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 31 Accessories Description For use with Part no. Article no. with LED display Front IP54 With approx. 3 m-long, plug-in connection cable (RJ45, 8-pin) with OLED display Front IP54 Multilingual With approx. 3 m-long, plug-in connection cable (RJ45, 8-pin) DC1, DA1 DX-KEY-LED 169132 DC1, DA1 DX-KEY-OLED 169133 Price see price list Std. pack Information relevant for export to North America 1 off UL/CSA certification not required DX-COM-STICK 169134 1 off UL/CSA certification not required DA1 DX-COM-SOFT 169136 1 off UL/CSA certification not required DC1, DA1 DX-CBL-RJ45-0M5 169137 DX-CBL-RJ45-1M0 169138 DX-CBL-RJ45-3M0 169139 1 off UL/CSA certification not required UL/CSA certification not required External keypad Bluetooth communications stick For transferring parameters to a computer with drivesConnect software via Bluetooth With 2 function keys for uploading DC1, DA1 and downloading parameters with configuration memory License Keys For enabling the drivesConnect program's PLC function Connection cable Connection cable with RJ45 plugs, 8 pole Length 0.5 m Length 1 m DC1, DA1 Length 3 m DC1, DA1 Bus termination resistor With 2 resistors, 120 Ω RJ45 plug, 8-pin for CANopen® and Modbus RTU DX-SPL-RJ45-2SL-1PLT DX-CBL-TERM 169140 1 off 8 pole RJ45 124 Ω Connection to PIN 1 and PIN 2 für CANopen® easyNet easyNet EASY-NT-R 256281 2 off RJ45, 8-pin, 2 sockets/1 plug DC1, DA1 DX-SPL-RJ45-2SL1PL 169142 1 off UL/CSA certification not required DX-CBL-PC-1M5 171018 1 off UL/CSA certification not required DX-COM-PCKIT 169135 1 off UL/CSA certification not required Cable and splitter Interface converter For directly connecting the variable-frequency drive to a computer with drivesConnect software Interface converter USB/RS485 with DC1, DA1 connection cable, RJ45, 8 pole electrically isolated USB PWR RxD TxD Interface converter USB/RS485 with connection cable, RJ45, 8 pole electrically isolated 1 × SUB-D plug, 9-pole Terminal strip, 5-terminal LED indicators DC1, DA1 CA04020001Z-EN-INT www.eaton.eu DC1, DA1 Accessories 32 PowerXL™ variable frequency drives Accessories Description For use with Part no. Article no. Price see price list 110-V-input (electrically isolated) 230-V-input (electrically isolated) 2 relay outputs 1 analog output 2 relay outputs DC1 DXC-EXT-IO110 169032 DXC-EXT-IO230 169033 DXC-EXT-2RO1AO 169030 DXC-EXT-2RO 169031 3 digital inputs 1 Relay output 3 relay outputs DA1 3 digital inputs 1 Relay output 1 Potentiometer DC1 DXC-EXT-LOCSIM 169034 1 off UL/CSA certification not required 2-channel max. 500 kHz 5 V TTL, A & B, /A & /B, 5 V DC, max. 200 mA 24 V HTL, A & B, /A & /B, 24 V DC, external power supply required, max. 30 V DC DA1 DXA-EXT-ENCOD 169035 1 off UL/CSA certification not required Std. pack Information relevant for export to North America Expansion modules 1 2 1 2 3 3 4 5 4 5 6 6 7 7 8 8 9 9 10 11 DC1 DC1 DC1 1 off 10 11 A DA1 B DXA-EXT-3DI1RO 169036 DXA-EXT-3RO 169121 Simulator 1 2 3 4 5 6 7 8 9 10 11 Encoder module A B CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 33 Fieldbus connection For use with Part no. Article no. Ethernet IP DA1 Modbus-TCP DA1 EtherCAT DA1 BACnet/IP DA1 PROFINET DA1 DeviceNet DA1 DX-NET-ETHERNET-2 169122 DX-NET-MODBUSTCP-2 169126 DX-NET-ETHERCAT-2 169127 DX-NET-BACNETIP-2 169128 DX-NET-PROFINET-2 169125 DX-NET-DEVICENET 169123 PROFIBUS-DP DA1 DX-NET-PROFIBUS 169124 SmartWire-DT DA1 (IP20) DX-NET-SWD1 169129 SmartWire-DT DC1/DA1 (IP55/IP66) DC1 (IP20) DX-NET-SWD2 169130 DX-NET-SWD3 169131 Price see price list Std. pack Information relevant for export to North America 1 off UL/CSA certification not required 1 off UL/CSA certification not required Fieldbus modules 2 x RJ45, 8 pole IN OUT Terminal strip, plug-in, 6-terminal A B SUB-D socket, 9-pole OP ST PROFIBUS DP-V1 SmartWire-DT Modules with slot for SWD4-8SF2-5 Ready with slot for SWD4-8SF2-5 SmartWire-DT Ready I A O CA04020001Z-EN-INT www.eaton.eu DC1, DA1 Accessories 34 PowerXL™ variable frequency drives Braking resistances Braking resistances Resistance value R Continuous braking rating PDB Ω kW Protection type For use with Part no. Article no. Price see price list Std. pack Information relevant for export to North America Braking resistances Braking resistance in anodized aluminium enclosure for direct installation in frequency inverter enclosure of frame sizes FS2 und FS3 100 0.2 IP54 DC1, DA1 Braking resistance in aluminum housing for direct installation in frequency inverter enclosure of frame sizes FS4 und FS5 33 0.5 IP54 DA1 Braking resistance in aluminum housing Installed in a housing designed to prevent accidental contact and featuring a temperature monitoring switch and a 1-meter connection cable 75 1.4 IP20 DC1, DA1 100 1.4 IP20 DC1, DA1 100 0.8 IP20 DC1, DA1 100 1.6 IP20 DC1, DA1 150 0.5 IP20 DC1, DA1 150 1.4 IP20 DC1, DA1 200 0.8 IP20 DC1, DA1 200 0.4 IP20 DC1, DA1 400 0.4 IP20 DC1, DA1 Braking resistance in aluminum housing Installed in a housing designed to prevent accidental contact and featuring a temperature monitoring switch and internal connecting terminals 35 1.1 IP20 DA1 50 0.4 IP20 DC1, DA1 50 9.8 IP20 DC1, DA1 100 0.2 IP20 DC1, DA1 100 0.4 IP20 DC1, DA1 DX-BR3-100 169150 1 off DX-BR5-033 169151 1 off DX-BR075-1K4 171917 DX-BR100-1K4 171896 DX-BR100-0K8 171907 DX-BR100-1K6 171924 DX-BR150-0K5 171916 DX-BR150-1K4 171895 DX-BR200-0K8 171894 DX-BR200-0K4 171915 DX-BR400-0K4 171914 1 off DX-BR035-1K1 171927 DX-BR050-0K4 171906 DX-BR050-0K8 171910 DX-BR100-0K2 171909 DX-BR100-0K4 171926 1 off Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Suitable for Max. Voltage Rating Degree of Protection Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Suitable for Max. Voltage Rating Degree of Protection CA04020001Z-EN-INT www.eaton.eu UL508; C22.2 E300773 NMTR2, NMTR8 E300773 14-M05 UL listed, certified by UL for use in Canada Branch circuits 600 IEC: IP00 UL508; C22.2 E300773 NMTR2, NMTR8 E300773 14-M05 UL listed, certified by UL for use in Canada Branch circuits 600 IEC: IP00 PowerXL™ variable frequency drives 35 Resistance value R Continuous braking rating PDB Ω kW Protection type For use with Braking resistance with steel wire mesh elements Installed in a housing designed to prevent accidental contact and featuring a temperature monitoring switch and internal connecting terminals 2 54.3 IP20 DA1 2 102.4 IP20 DA1 6 5.1 IP20 DA1 6 9.2 IP20 DA1 6 18.1 IP20 DA1 6 33.3 IP20 DA1 12 3.1 IP20 DA1 12 5.1 IP20 DA1 12 9.2 IP20 DA1 12 18.1 IP20 DA1 22 1.4 IP20 DA1 22 3.1 IP20 DA1 22 5.1 IP20 DA1 22 9.2 IP20 DA1 40 3.1 IP20 DA1 40 5.1 IP20 DA1 47 3.1 IP20 DC1, DA1 47 5.1 IP20 DC1, DA1 47 9.2 IP20 DC1, DA1 50 3.1 IP20 DC1, DA1 50 5.1 IP20 DC1, DA1 75 5.1 IP20 DC1, DA1 100 6.2 IP20 DC1, DA1 Part no. Article no. DX-BR002-54K3 171923 DX-BR002-102K4 171903 DX-BR006-5K1 171913 DX-BR006-9K2 171893 DX-BR006-18K1 171922 DX-BR006-33K3 171902 DX-BR012-3K1 171912 DX-BR012-5K1 171929 DX-BR012-9K2 171921 DX-BR012-18K1 171901 DX-BR022-1K4 171911 DX-BR022-3K1 171928 DX-BR022-5K1 171920 DX-BR022-9K2 171900 DX-BR040-3K1 171919 DX-BR040-5K1 171899 DX-BR047-3K1 171908 DX-BR047-5K1 171925 DX-BR047-9K2 171905 DX-BR050-3K1 171918 DX-BR050-5K1 171898 DX-BR075-5K1 171897 DX-BR100-6K2 171904 Price see price list Std. pack Information relevant for export to North America 1 off Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Suitable for Max. Voltage Rating Degree of Protection CA04020001Z-EN-INT UL508; C22.2 E300773 NMTR2, NMTR8 E300773 14-M91 UL listed, certified by UL for use in Canada Branch circuits 1000 IEC: IP00 www.eaton.eu DC1, DA1 Braking resistances 36 PowerXL™ variable frequency drives Mains chokes, motor chokes Mains chokes, motor chokes Rated operational current Ie Inductance Maximum heat dissipation L Pv A mH W Single-phase max. permitted mains supply voltage V AC: 260 V + 0% (50/60 Hz) 5.8 5.05 9 8.6 3.41 11 13 2.25 12 18 1.63 17 24 1.22 20 32 0.92 24 7.51 17 6 4.9 19 10 2.94 33 16 1.84 44 25 1.18 57 40 0.64 59 50 0.37 58 60 0.31 60 80 0.23 86 100 0.18 101 120 0.15 100 160 0.11 140 200 0.09 154 250 0.07 155 300 0.06 196 303 0.06 230 370 0.05 290 450 0.04 300 Part no. Article no. Price see price list Std. pack Mains chokes three-phase max. permitted mains supply voltage V AC: 550 V + 0% (50/60 Hz) 3.9 Motor chokes 1 off DX-LN3-004 269500 DX-LN3-006 269501 DX-LN3-010 269502 DX-LN3-016 269503 DX-LN3-025 269504 DX-LN3-040 269505 DX-LN3-050 269506 DX-LN3-060 269507 DX-LN3-080 269508 DX-LN3-100 269509 DX-LN3-120 269510 DX-LN3-160 269511 DX-LN3-200 269512 DX-LN3-250 269513 DX-LN3-300 269514 DX-LN3-303 169143 DX-LN3-370 169144 DX-LN3-450 169145 1 off DX-LM3-005 269538 DX-LM3-008 269539 DX-LM3-011 269541 DX-LM3-016 269542 DX-LM3-035 269543 DX-LM3-050 269544 1 off max. heat dissipation (pulse frequency) (12 kHz) three-phase max. permitted mains supply voltage V AC: 750 V + 0% (50/60 Hz) 5 CA04020001Z-EN-INT DX-LN1-006 269490 DX-LN1-009 269495 DX-LN1-013 269496 DX-LN1-018 269497 DX-LN1-024 269498 DX-LN1-032 169791 www.eaton.eu 2 24 8 4.1 54 11 3 71 16 1.5 78 35 1 116 50 0.6 168 PowerXL™ variable frequency drives 37 Motor chokes, sine filters Motor chokes, sine filters Inductance Maximum heat dissipation L Pv A mH W Motor chokes Part no. Article no. Price see price list Std. pack DC1, DA1 Rated operational current Ie max. heat dissipation (pulse frequency) (12 kHz) three-phase max. permitted mains supply voltage V AC: 750 V + 0% (50/60 Hz) 63 0.5 193 80 0.5 206 100 0.45 294 150 0.35 424 180 0.3 439 220 0.2 517 260 0.15 520 303 0.15 - 370 0.12 - 450 0.1 - 4 11 50 10 5.1 100 16.5 3.07 70 23.5 2.5 125 32 2 100 37 1.7 100 48 1.2 240 61 1 280 72 0.95 300 90 0.8 290 115 0 460 150 0.5 530 180 0.4 500 250 0.35 550 440 0.14 650 480 0.14 1550 DX-LM3-063 269545 DX-LM3-080 269546 DX-LM3-100 269547 DX-LM3-150 269548 DX-LM3-180 269549 DX-LM3-220 269560 DX-LM3-260 269561 DX-LM3-303 169146 DX-LM3-370 169147 DX-LM3-450 169148 1 off DX-SIN3-004 271538 DX-SIN3-010 271590 DX-SIN3-016 271591 DX-SIN3-023 271593 DX-SIN3-032 271594 DX-SIN3-037 271595 DX-SIN3-048 271597 DX-SIN3-061 271599 DX-SIN3-072 271600 DX-SIN3-090 271601 DX-SIN3-115 271602 DX-SIN3-150 271603 DX-SIN3-180 271604 DX-SIN3-250 271605 1 off DX-SIN3-440 271606 DX-SIN3-480 169149 1 off Sine filter three-phase Instructions 1 off Information relevant for export to North America Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Suitable for Max. Voltage Rating Degree of Protection UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking E167225 XPTQ2, XPTQ8 UL report applies to both US and Canada 3211-06 UL listed, certified by UL for use in Canada Branch circuits 1~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) IEC: IP00 CA04020001Z-EN-INT www.eaton.eu 38 PowerXL™ variable frequency drives Radio interference suppression filters Radio interference suppression filters Input current For use with Part no. Article no. DC1-12 DA1-12… DX-EMC12-008 172273 DX-EMC12-012 172274 DX-EMC12-016 172275 DX-EMC12-020 172276 DX-EMC12-030 172277 1 off DC1-32… DC1-34… DA1-32… DA1-34… DX-EMC34-008 172278 DX-EMC34-012 172279 DX-EMC34-016 172280 DX-EMC34-030 172281 1 off DA1-32… DA1-34… DX-EMC34-042 172282 DX-EMC34-055 172283 DX-EMC34-075 172284 DX-EMC34-100 172285 DX-EMC34-130 172286 DX-EMC34-180 172287 DX-EMC34-250 172288 DX-EMC34-400 172289 ILN Price see price list Std. pack T Radio interference suppression filters Single-phase Mains voltage (50/60Hz) ULN [V] max. 240 + 10% Base-mounted filter 8 12 16 20 30 three-phase Mains voltage (50/60Hz) ULN [V] max. 480 + 10% Base-mounted filter 8 12 16 30 Mounting to the side, next to the variable frequency drive 42 55 75 100 130 180 250 400 CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 39 Assigned switching and protective elements Engineering AC supply system: Variable-frequency drives can be connected without restriction to AC supply systems with a grounded star point (TN/TT grounding systems). Directly connecting them to and running them on unbalanced or B phase-grounded systems (e.g., USA) is not permissible. Fuses (circuit-breakers) allow the protection of lines and electrical devices. For the protection of persons, AC/DC-sensitive residual current circuit-breakers (RCD Type B) are required in addition. F Contactors are used to switch the mains voltage on and off. Q Mains choke damp harmonic distortion (THD) and current peaks and limit inrush currents (the DC link capacitors' charging current). In addition, they protect the mains rectifier from voltage peaks coming from the mains. R Radio interference suppression filter attenuate high-frequency electromagnetic emissions from devices. They ensure that the EMC limit values for conducted interference specified in the applicable product standards are complied with (variable-frequency drives). Note: External radio interference suppression filters (optional) make it possible to use longer motor cables and have low leakage currents. Normally, they should only be used with variable-frequency drives that do not feature an internal radio interference suppression filter. Exception: directly assigned variable-frequency drives with internal filters (calibrated combination) K variable frequency drive allow the continuously variable speed control of threephase motors. To do this, the variable-frequency drive converts the voltage of the AC supply system with a constant voltage and a constant frequency to a new AC voltage with a variable amplitude and a variable frequency. L1/L L2/N L3 T 3~ R On brake resistor converts the variable frequency drive's regenerative braking energy into heat. The variable frequency drive must be equipped with a brake chopper, which connects the braking resistance parallel to the internal DC link. 1 2 3 4 5 6 7 U 8 9 10 11 V W Motor choke • Compensate the capacitive capacitive currents, • Reduce current ripple and the motor’s current change noise, • Attenuate the retroaction on parallel connection of several motors. R sine filter • Smoothen the output voltage sinusoidally, • reduce motor noise through du/dt reduction, and thereby increase the motor insulation’s lifespan, • Reduce the leakage currents to allow better motor performance at improved EMC values. 3 3 Screened motor cables attenuate radiated and conducted high-frequency emissions within the limits defined in the applicable product standard (EMC). They must be connected to the earth potential on both sides across a large area (PES). M M 3~ Three-phase asynchronous motor (standard motor) converts electric power (P ~ U × I) into mechanical power (P ~ M × n). Equipment code F = fuses and circuit-breakers Q = controlled switching within energy flow (contactors, circuit-breakers) R = limitation (reactors, resistors) K = radio interference suppression filters T = variable-frequency drives M = motors CA04020001Z-EN-INT www.eaton.eu DC1, DA1 Assigned switching and protective elements 40 PowerXL™ variable frequency drives General information on Engineering Electrical mains connection General information on Engineering Frequency inverters can be connected to and operated on star point-earthed AC supply systems (as per IEC 60364) without restrictions. L1 L2 L3 N PE L1 L2 L3 PEN Connecting them to and operating them on asymmetrically earthed networks, such as phase-earthed delta networks (grounded delta, USA) or non-earthed or high-resistance earthed (> 30 Ω) IT networks is permitted with limitations. In these networks, only frequency inverters without internal radio interference suppression filters (EMC) may be used. In the case of devices with an integrated radio interference suppression filter, the filter’s protective earth connection must be disconnected. The standardized rated operating voltages of the utility companies fulfil the following conditions at the point of transfer to the consumer: • maximum deviation from the rated voltage (ULN): ±10 % • Maximum deviation in the voltage symmetry: ±3 % • Maximum deviation from the rated frequency: ±4 % A further voltage drop of up to 4% in the consumer networks is permissible relative to the lower voltage value (ULN -10%) of the mains voltage. In ring-operated mesh networks (such as in the EU) the standardized consumer voltages (230/400/690 V) are identical to the utility company’s supply voltages. In star networks (for example in North America/USA), the stated consumer voltages take the voltage drop from the utility company’s infeed point to the last consumer into account. Table: North American voltage level Motor voltage according Consumer voltage, rated Supply voltage ULN of the EVU to UL 508 C value for the motors 120 V 110 - 120 V 115 V 240 V 220 - 240 V 230 V 480 V 440 - 480 V 460 V 600 V 550 - 600 V 575V Public medium-voltage system Public low-voltage system Category C1 / C2 For frequency inverters, the components placed on the mains-side are assigned as per the input-side rated operational current ILN and the AC-1 utilization category. Fuses, circuit-breakers and conductor cross-sections must meet the national and regional requirements and the required approvals at the point of operation. For fire prevention and the protection of persons and domestic animals from excessive contact voltages residual current devices (RCD) must be used. Only AC/DC sensitive residual current devices (RCD, type B) may be used in connection with a frequency inverter. Frequency inverters work with fast electronic switches (IGBT) in the inverter. This can cause radio interference in a drive system, which, in turn, can adversely affect nearby electronic equipment. To provide protection from this high-frequency interference, these should be spatially separated and screened from frequency-controlled drives. In Europe, adherence to the EMC Directive is mandatory. The EMC product standard for power drive systems (PDS) is IEC/EN 61800-3. This standard covers the complete drive system, from mains infeed to the motor. Both versions of DC1 and DA1 series frequency inverters (with internal/ external radio interference suppression filter) meet the requirements of the EMC product standard for residential areas (first environment) and therefore the higher limits for industrial environment (second environment) as well. Marking on residual current devices for AC/DC sensitive RCDs, type B: Earth leakage currents will be produced when using frequencycontrolled drives due to the nature of the system. The main reasons for this consist of external capacitances between the phases of the motor cable, the motor cable's screening, Y capacitors in the frequency inverter, and radio interference suppression filters, as well as earthing measures at the motor's site of operation. These leakage currents can exceed 3.5 mA and require improved PDS earthing as per EN 50178 (earth conductor crosssection ≥ 10 mm2). CA04020001Z-EN-INT www.eaton.eu Category C1 / C2 Category C3 / C4 Category C3 / C4 Category C2 1.or 2. environment 1. Environment 2. Environment Frequency inverters A frequency inverter is an electronic apparatus used for the variable-speed control of three-phase motors. It is intended for installation in a machine or for assembly with other components to a machine or plant. The main components of a modern compact frequency inverter are a power section ① and a control section ②. The functional control of the frequency inverter and the output values in the power section (such as frequency, voltage and current) can be adjusted through: • Control terminals (I/O) with analog and digital (binary) inputs, • A keypad with function keys and display units, • Serial interfaces (BUS) with RS485 (Modbus RTU) and optional fieldbus connections (CANopen, PROFIBUS-DP etc.) and an optional PC connection. Internal open and closed-loop control circuits monitor all variable values in the frequency inverter and automatically switch the process off if a value reaches a dangerous level. The power section of a static compact frequency generally consists of three subgroups: • Rectifier (A), • Internal DC link (B), • Inverter module (C). ① DC- L1/L L2/N L3 ② COM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 EMC compliance Industrial mains Category C1 DC+ BR Safety and switching Private mains PCC U 18 V W ① Power section with: A = Rectifier B = Internal DC link C = inverter (IGBT) ② Control section with: I/O = Analog and binary inputs and outputs KEYPAD = Operating unit with display unit BUS = Serial ports/interfaces (RS485, field bus, PC interface) I/O KEYPAD BUS CPU M 3∼ A ULN = phase voltage fromsupplying AC mains B UDC = DC link voltage UDC = 1.41 x ULN C Output voltage = switched DC link voltage with sinusoidal pulse width modulation (PWM) Block diagram with main components of a frequency inverter PowerXL™ variable frequency drives 41 Control methods Bei der In sensorless vector control the magnetic fields of the stator and rotor windings are aligned so as to oppose each other. With asynchronous motors the magnetic flux in the rotor must be mapped in an electronic model of the motor. This requires the physical parameters on the motor’s rating plate to be entered. In vector operation the frequencyinverter can control only one motor. A parallel operation of several motors is not possible here. The exact calculation of the phase voltages at the variable frequency drive’s output, however, improves the motor’s operational behavior. The motor also heats up less in the lower speed range. The field-oriented vector control results in a significant improvement in the drive dynamics as well as optimizing performance; it also increases the range of possible applications. The main applications of sensorlessvector control are: General information on Engineering The IGBTs in the variable frequency series' inverter are controlled with sinusoidal pulse-width modulation (PWM). In real-life applications, the industry draws a distinction between the following control methods: • Voltage frequency control (U/f control), • V/Hz control with slip compensation • Sensorless vector control (speed control) • Vector control (closed-loop) The Voltage frequency control is the best known and most commonly used method. A simple characteristic curve (linear or quadratic) defines the motor’s rotating field frequency and the corresponding three-phase lineto-line motor voltage is selected such that the motor is neither over nor under-magnetized. X1 ① Xh ② ③ ① Stator winding ② Air gap ③ Transformed rotor winding Simplified equivalent circuit diagram for a three-phase motor • Material machining and processing equipment • Condensors (compressor), • Heavy starting duty (extruder, agitators, mixer), • Horizontal conveying equipment (cranes, elevators). Bei der V/Hz control with slip compensation can compensate for the load-dependent speed change in individual drives (sensorless). iw iμ u1 R'2 s X'2 i1 Main applications of U/f control: • pump and fan drives, • horizontal conveying and transportation systems, • multiple motor drives (parallel operation of several motors at the variable frequency drive’s output). R1 Bei der Vector control uses the variable frequency drive's output current as a controlled variable. This makes it possible to perfectly adjust the three-phase motor in line with the corresponding torque boost. The motor speed can be controlled in connection with an rpm sensor (tachometer, pulse generator) (closed loop). Motor model Explanation: Regardless of the control method used, a variable frequency drive uses the measured voltage and current values on the stator winding (u1, i1) to calculate the required manipulated variable for flux-generating component iμ and torque-generating component in the rotor iw. The motor's load dependent slip is represented as resistor R‘2/s. During no-load operation, this value approaches infinity (iw → 0). On the other hand, the value approaches zero as the load increases. The current in the rotor grows at this point. EMC = Electromagnetic compatibility EVU = Utility company IGBT = Insulated-gate bipolar transistor PDS = Magnet system RCD = Residual current device Technical information concerning braking resistances: The braking resistors' specified PDB power dissipation applies to continuous operation. In short-time operation these values can be increased by multiplying them with the type-specific power factor using the following formula: Pmax ≤ (PDB × 100 %) ÷ ED [%] Pmax = maximum pulse rating PDB = continuous rating at a duty factor of 100 % ED = duty factor tc = Cycle time (max. 120 seconds) The duty factor is stated as a percentage (%) and is calculated with the formula: ED [%] = (ED × 100 %) ÷ tc Pmax PDB t [s] ED tC (F 120 s) 20 10 6 3.4 PDB ED 1 1.1 1.25 1.4 1.7 100 90 80 70 60 2 50 2.6 40 30 20 10 5 ED [%] CA04020001Z-EN-INT www.eaton.eu DC1, DA1 General information on Engineering 42 PowerXL™ variable frequency drives Connection example for DC1 Connecting example for a 0.75 kW motor with the rating plate illustrated here. To ensure ideal operational behavior (e.g., slip compensation, vector control, etc.), the data on the motor’s rating plate should be entered into the variable frequency drive (electric motor map). Connection example for DC1 The variable frequency drives are configured by default in such a way that they can be operated immediately with V/Hz control when connected to the assigned motor rating without having to configure any additional parameters. The following example shows the necessary parameter settings for a variable frequency drive (a DC1 in this example) P-08 P-07 230/400 V 3.2/1.9 A cosϕ 0.79 0.75 kW 1410 min -1 50 Hz P-10 P-09 8 RUN 9 10 11 6 A, 250 VAC 5 A, 30 VDC 7 0V AI1 DI4 f-Out + 6 0...+10 V < 20 mA AO +24 V DO 5 0V 10 V 4 +10 V Out < 10 mA f-Soll 0...+10 V FF1 DI2 3 DI3 AI2 2 REV EMC ① 1 +24 V Out < 100 mA L1/L L2/N L3 FWD 24 V 3 AC 230 V 3 AC 400/480 V 50/60 Hz DI1 and connection examples for singlephase and three-phase mains voltages: VAR DCDC+ CPU BR X1 PIN 8 (PIN2) PIN 7 (PIN 1) U V RS485 W ① PES FS2, FS3 3 AC 230/400/460 V M 3~ Block diagram for DC1-32... and DC1-34... with internal radio interference suppression filter ① Only sizes FS2 and FS3 have connection terminals DC+ and BR- for an external braking resistance (optional). The control signal terminals are factory set as follows: 1: 24 V: +24 V control voltage, max. 100 mA 2: DI1: FWD = Clockwise rotating field enable (Forward) 3: DI2: REV = Anticlockwise rotating field enable (Reverse) 4: DI3: FF1 = Fixed frequency 1 or AI2 5: 10 V: +10 V reference voltage, max. 10 mA 6: AI1: f-setpoint = Frequency setpoint value (0 - +10 V) 7: 0 V, reference potential 8: AO: f-Out = Output frequency to motor (0 - +10 V) CA04020001Z-EN-INT www.eaton.eu 9: 0 V, reference potential 10/11: Relay: RUN = Operating signal (N/O) DI: Digital input = +24 VDC digital input AI: Analog input = 0 - 10 V, 0/4 - 20 mA analog input DO: Digital output = +24 VDC, max. 20 mA digital output AO: Analog output = 0 - +10 V, max. 20 mA analog output Parameters are used to define the function and mode of operation for the digital and analog inputs/outputs. These parameters are described in manual MN04020003Z. PowerXL™ variable frequency drives 43 Connection example for DC1 Connection example for a 0.75 kW motor Motor: P = 0.75 kW Mains: 3/N/PE 400 V 50/60 Hz Connection examples meeting EMC requirements: Power section (see figure below) Variant A: The previously indicated 0.75 kW motor can be connected in a delta configuration for a single-phase 230-V supply system (version A) or in a star configuration for a 400-V supply system (version B). The frequency inverter and the type-specific accessories are selected for 1 AC 230 V (DC1-124D3...) or for 3 AC 400 V (MMX34AA2D4) depending on the mains voltage selected. Variant B: Motor in delta configuration Motor in star configuration DC1… frequency inverter with single-phase mains supply (230 V) DC1… frequency inverter with three-phase mains supply (400 V) 1 ∼ 230 V, 50/60 Hz 3 ∼ 400 V, 50/60 Hz L N PE FAZ-B10/1N L1 L2 L3 PE F1 Q1 PKM0-6,3 I Q1 DILM7 (+DILM12-XP1) ① U1 V1 W1 PE R1 2 DX-LN3-004 L1 I Q11 PE R1 DX-LN1-009 DILEM-10 1 I L2/N U2 V2 W2 PE L1 L2/N L3 PE DC1-124D3… (4.3 A) W PE V U T1 DC1-342D2… (2.2 A) PES W PE V U T1 PES PES X1 PES PES X1 PES PES PES M 3~ M1 M 3~ M1 U1 V1 W1 W2 U2 V2 U1 230 V 3.2 A 0.75 kW V1 W1 W2 U2 V2 400 V 1.9 A 0.75 kW ① Optional connection option for single-phase connections CA04020001Z-EN-INT www.eaton.eu DC1, DA1 Connection example for DC1 44 PowerXL™ variable frequency drives PowerXL™ variable frequency drives Assigned switching and protective elements 45 Assigned switching and protective elements Engineering Part no. Motor Assigned motor rating 1) P P Rated motor current Ie kW HP A DC1, DA1 Assigned switching and protective elements Braking resistances for duty factors (DF) as a %3) Frequency inverters Power Wiring Motor connection Rated operational current2) Ie Input current Protection device Protection device Contactor Mains choke Motor choke Sine filter 10% 20% 40% A T ILN Ue230 V AC, 1-phase/U2230 V AC, 3-phase DC1-122D3 0.37 0.5 2 2.3 5 FAZ-B10/1N - DILM7 DX-LN1-006 DX-LM3-005 DX-SIN3-004 - - - DC1-124D3 0.75 1 3.2 4.3 8.5 FAZ-B10/1N - DILM7 DX-LN1-013 DX-LM3-005 DX-SIN3-010 - - - DC1-127D0 1.5 2 6.3 7 13.9 FAZ-B16/1N - DILM7 DX-LN1-018 DX-LM3-008 DX-SIN3-010 DX-BR050-0K4 DX-BR050-0K8 DX-BR047-3K1 DC1-12011 2.2 3 8.7 10.5 19.5 FAZ-B25/1N - DILM7 DX-LN1-024 DX-LM3-011 DX-SIN3-016 DX-BR050-0K4 DX-BR050-0K8 DX-BR047-3K1 DC1-12015 4 5 14.8 15 30.5 FAZ-B40/1N - DILM7 DX-LN1-032 DX-LM3-016 DX-SIN3-016 DX-BR050-0K4 DX-BR050-0K8 DX-BR047-3K1 Ue230 V AC, 3-phase/U2230 V AC, 3-phase DC1-322D3 0.37 0.5 2 2.3 3 FAZ-B6/3 PKM0-6,3 DILM7 DX-LN3-004 DX-LM3-005 DX-SIN3-004 - - - DC1-324D3 0.75 1 3.2 4.3 4.5 FAZ-B6/3 PKM0-6,3 DILM7 DX-LN3-006 DX-LM3-005 DX-SIN3-010 - - - DC1-327D0 1.5 2 6.3 7 7.3 FAZ-B10/3 PKM0-10 DILM7 DX-LN3-010 DX-LM3-008 DX-SIN3-010 DX-BR050-0K4 DX-BR050-0K8 DX-BR047-3K1 DC1-32011 2.2 3 8.7 10.5 11 FAZ-B16/3 PKM0-16 DILM7 DX-LN3-016 DX-LM3-011 DX-SIN3-016 DX-BR050-0K4 DX-BR050-0K8 DX-BR047-3K1 DC1-32018 4 5 14.8 18 18.8 FAZ-B20/3 PKM0-20 DILM7 DX-LN3-025 DX-LM3-035 DX-SIN3-023 DX-BR050-0K4 DX-BR050-0K8 DX-BR047-3K1 Ue400 V AC, 3-phase/U2400 V AC, 3-phase DC1-342D2 0.75 1 1.9 2.2 2.4 FAZ-B6/3 PKM0-6,3 DILM7 DX-LN3-004 DX-LM3-005 DX-SIN3-004 - - - DC1-344D1 1.5 2 3.6 4.1 4.3 FAZ-B6/3 PKM0-6,3 DILM7 DX-LN3-006 DX-LM3-005 DX-SIN3-010 DX-BR100-0K8 DX-BR100-1K6 DX-BR100-6K2 DC1-345D8 2.2 3 5 5.8 6.1 FAZ-B10/3 PKM0-10 DILM7 DX-LN3-010 DX-LM3-008 DX-SIN3-010 DX-BR100-0K8 DX-BR100-1K6 DX-BR100-6K2 DC1-349D5 4 5 8.5 9.5 9.8 FAZ-B16/3 PKM0-16 DILM7 DX-LN3-010 DX-LM3-011 DX-SIN3-010 DX-BR100-0K8 DX-BR100-1K6 DX-BR100-6K2 DC1-34014 5.5 7.5 11.3 14 14.6 FAZ-B20/3 PKM0-20 DILM7 DX-LN3-016 DX-LM3-016 DX-SIN3-016 DX-BR047-3K1 DX-BR047-5K1 DX-BR047-9K2 DC1-34018 7.5 10 15.2 18 18.1 FAZ-B25/3 PKM0-25 DILM7 DX-LN3-025 DX-LM3-035 DX-SIN3-023 DX-BR047-3K1 DX-BR047-5K1 DX-BR047-9K2 DC1-34024 11 15 21.7 24 24.7 FAZ-B32/3 PKM0-32 DILM17 DX-LN3-025 DX-LM3-035 DX-SIN3-023 DX-BR047-3K1 DX-BR047-5K1 DX-BR047-9K2 Ue230 V AC, 1-phase/U2230 V AC, 3-phase DA1-124D3 0.75 1 3.2 4.3 8.5 FAZ-B10/1N - DILM7 DX-LN1-013 DX-LM3-005 DX-SIN3-010 DX-BR100-0K2 DX-BR100-0K4 - DA1-127D0 1.5 2 6.3 7 13.9 FAZ-B16/1N - DILM7 DX-LN1-018 DX-LM3-008 DX-SIN3-010 DX-BR050-0K4 DX-BR050-0K8 - DA1-12011 2.2 3 8.7 10.5 19.5 FAZ-B25/1N - DILM7 DX-LN1-024 DX-LM3-011 DX-SIN3-016 DX-BR050-0K8 DX-BR035-1K1 - Ue230 V AC, 3-phase/U2230 V AC, 3-phase DA1-324D3 0.75 1 3.2 4.3 4.5 FAZ-B6/3 PKM0-6,3 DILM7 DX-LN3-006 DX-LM3-005 DX-SIN3-010 DX-BR100-0K2 DX-BR100-0K4 - DA1-327D0 1.5 2 6.3 7 7.3 FAZ-B10/3 PKM0-10 DILM7 DX-LN3-010 DX-LM3-008 DX-SIN3-010 DX-BR050-0K4 DX-BR050-0K8 - DA1-32011 2.2 3 8.7 10.5 11 FAZ-B16/3 PKM0-16 DILM7 DX-LN3-016 DX-LM3-011 DX-SIN3-016 DX-BR050-0K8 DX-BR035-1K1 - DA1-32018 4 5 14.8 18 18.8 FAZ-B20/3 PKM0-20 DILM7 DX-LN3-025 DX-LM3-035 DX-SIN3-023 DX-BR022-1K4 DX-BR022-3K1 - DA1-32024 5.5 7.5 19.6 24 24.8 FAZ-B32/3 PKM0-32 DILM17 DX-LN3-025 DX-LM3-035 DX-SIN3-032 DX-BR022-1K4 DX-BR022-3K1 - DA1-32039 7.5 10 26.4 39 40 FAZ-B50/3 - DILM25 DX-LN3-040 DX-LM3-050 DX-SIN3-048 DX-BR022-1K4 DX-BR022-3K1 - DA1-32046 11 15 38 46 47.1 FAZ-B63/3 - DILM40 DX-LN3-050 DX-LM3-050 DX-SIN3-048 DX-BR022-1K4 DX-BR022-3K1 - DA1-32061 15 20 51 61 62.4 NZMC1-S80 - DILM50 DX-LN3-080 DX-LM3-063 DX-SIN3-061 DX-BR012-3K1 DX-BR012-5K1 - DA1-32072 18.5 25 63 72 74.1 NZMC1-S80 - DILM65 DX-LN3-080 DX-LM3-080 DX-SIN3-072 DX-BR012-3K1 DX-BR012-5K1 - DA1-32090 22 30 71 90 92.3 NZMC2-S100 - DILM80 DX-LN3-100 DX-LM3-100 DX-SIN3-090 DX-BR006-5K1 DX-BR006-9K2 - DA1-32110 30 40 96 110 112.7 NZMC2-S125 - DILM95 DX-LN3-120 DX-LM3-150 DX-SIN3-115 DX-BR006-5K1 DX-BR006-9K2 - DA1-32150 45 50 141 150 153.5 NZMC2-S160 - DILM150 DX-LN3-160 DX-LM3-150 DX-SIN3-150 DX-BR006-5K1 DX-BR006-9K2 - DA1-32180 55 60 173 180 183.8 NZMC2-S200 - DILM170 DX-LN3-200 DX-LM3-180 DX-SIN3-180 DX-BR006-5K1 DX-BR006-9K2 - DA1-32202 55 75 173 202 206.2 NZMC3-S250 - DILM185A DX-LN3-250 DX-LM3-220 DX-SIN3-250 DX-BR006-5K1 DX-BR006-9K2 - DA1-32248 75 100 233 248 252.8 NZMC3-S320 - DILM185A DX-LN3-300 DX-LM3-260 DX-SIN3-250 DX-BR006-5K1 DX-BR006-9K2 - 1) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0 3) Only for devices with an internal braking chopper 2) With CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives PowerXL™ variable frequency drives Assigned switching and protective elements Part no. Motor Braking resistances for duty factors (DF) as a %3) Frequency inverters Power Wiring Rated operational current2) Ie Input current Protection device Protection device Contactor Mains choke Motor choke Sine filter 10% 20% 40% A T Ue400 V AC, 3-phase/U2400 V AC, 3-phase DA1-342D2 0.75 1 1.9 2.2 2.4 FAZ-B6/3 PKM0-6,3 DILM7 DX-LN3-004 DX-LM3-005 DX-SIN3-004 DX-BR400-0K4 DX-BR400-0K4 - DA1-344D1 1.5 2 3.6 4.1 4.3 FAZ-B6/3 PKM0-6,3 DILM7 DX-LN3-006 DX-LM3-005 DX-SIN3-010 DX-BR200-0K4 DX-BR200-0K8 - DA1-345D8 2.2 3 5 5.8 6.1 FAZ-B10/3 PKM0-10 DILM7 DX-LN3-010 DX-LM3-008 DX-SIN3-010 DX-BR150-0K5 DX-BR150-1K4 - DA1-349D5 4 5 8.5 9.5 9.8 FAZ-B16/3 PKM0-16 DILM7 DX-LN3-010 DX-LM3-011 DX-SIN3-010 DX-BR100-0K8 DX-BR100-1K4 - DA1-34014 5.5 7.5 11.3 14 14.6 FAZ-B20/3 PKM0-20 DILM7 DX-LN3-016 DX-LM3-016 DX-SIN3-016 DX-BR075-1K4 DX-BR075-5K1 - DA1-34018 7.5 10 15.2 18 18.1 FAZ-B25/3 PKM0-25 DILM7 DX-LN3-025 DX-LM3-035 DX-SIN3-023 DX-BR050-3K1 DX-BR050-5K1 - DA1-34024 11 15 21.7 24 24.7 FAZ-B32/3 PKM0-32 DILM17 DX-LN3-025 DX-LM3-035 DX-SIN3-023 DX-BR040-3K1 DX-BR040-5K1 - DA1-34030 15 20 29.3 30 30.8 FAZ-B40/3 - DILM17 DX-LN3-040 DX-LM3-035 DX-SIN3-032 DX-BR022-5K1 DX-BR022-9K2 - DA1-34039 18.5 25 36 39 40 FAZ-B50/3 - DILM25 DX-LN3-040 DX-LM3-050 DX-SIN3-048 DX-BR022-5K1 DX-BR022-9K2 - DA1-34046 22 30 41 46 47.1 FAZ-B63/3 - DILM40 DX-LN3-050 DX-LM3-050 DX-SIN3-048 DX-BR022-5K1 DX-BR022-9K2 - DA1-34061 30 40 55 61 62.8 NZMC1-S80 - DILM50 DX-LN3-080 DX-LM3-063 DX-SIN3-061 DX-BR012-9K2 DX-BR012-18K1 - DA1-34072 37 50 68 72 73.8 NZMC1-S80 - DILM65 DX-LN3-080 DX-LM3-080 DX-SIN3-090 DX-BR012-9K2 DX-BR012-18K1 - DA1-34090 45 60 81 90 92.2 NZMC1-S100 - DILM80 DX-LN3-100 DX-LM3-100 DX-SIN3-115 DX-BR006-18K1 DX-BR006-33K3 - DA1-34110 55 75 99 110 112.5 NZMC2-S125 - DILM95 DX-LN3-120 DX-LM3-150 DX-SIN3-115 DX-BR006-18K1 DX-BR006-33K3 - DA1-34150 75 100 134 150 153.2 NZMC2-S160 - DILM150 DX-LN3-160 DX-LM3-150 DX-SIN3-150 DX-BR006-18K1 DX-BR006-33K3 - DA1-34180 90 150 161 180 183.7 NZMC2-S200 - DILM170 DX-LN3-200 DX-LM3-180 DX-SIN3-180 DX-BR006-18K1 DX-BR006-33K3 - DA1-34202 110 175 196 202 205.9 NZMC3-S250 - DILM185A DX-LN3-250 DX-LM3-220 DX-SIN3-250 DX-BR006-18K1 DX-BR006-33K3 - DA1-34240 132 200 231 240 244.5 NZMC3-S320 - DILM185A DX-LN3-250 DX-LM3-260 DX-SIN3-250 DX-BR006-18K1 DX-BR006-33K3 - DA1-34302 160 250 279 302 307.8 NZMC3-S400 - DILM225A DX-LN3-370 DX-LM3-303 DX-SIN3-440 DX-BR006-18K1 DX-BR006-33K3 - DA1-34370 200 300 349 370 - NZMC3-S400 - - - - - DX-BR002-54K3 DX-BR002-102K4 - DA1-34450 250 350 437 450 - NZMC3-S500 - - - - - DX-BR002-54K3 DX-BR002-102K4 - Assigned motor rating 1) P P Rated motor current Ie kW HP A 47 Assigned switching and protective elements Motor connection DC1, DA1 46 ILN 1) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) 2) With a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0 3) Only for devices with an internal braking chopper CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 48 PowerXL™ variable frequency drives PowerXL™ variable frequency drives DC1 (U (Ue: 115 VV AC, AC, single-phase, single-phase, UU2: 115VVAC, AC,single-phase/230 single-phase/230VVAC, AC,33phase) phase) e: 115 2: 115 49 DC1 (Ue: 115 V AC,DC1 single-phase, V AC, single-phase/230 AC, 3 phase) (Ue: 230 VUAC, single-phase, U2: 230 V AC,Vsingle-phase) 2: 115 DC1 (Ue: 115 V AC, single-phase, U2: 115 V AC, single-phase/230 V AC, 3 phase)DC1 (Ue: 230 V AC, single-phase, U2: 230 V AC, single-phase) DC1-S1011… DC1-1D2D3… DC1-1D4D3… DC1-1D5D3… DC1-S24D3… DC1-S27D0… DC1, DA1 DC1-S17D0… General Climatic proofing ρw % Mounting position Altitude m Protection against direct contact < 95 %, average relative humidity (RH), non-condensing (EN 50178) < 95 %, average relative humidity (RH), non-condensing (EN 50178) Vertical Vertical 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments Radio interference level Radio interference class (EMC) Environment (EMC) 1st and 2nd environments longest permissible length of motor cable I m 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) - - Main circuit Supply Rated operational voltage Ue 115 V AC, single-phase Notes - - 230 V AC, 1-phase The mains voltage of 115 V is raised to 230 V (output voltage) through an internal voltage double connection. - Mains voltage (50/60Hz) ULN V 110 (-10%) - 115 (+10%) Input current ILN T 8.5 12.5 11 19 25 6 9.3 14 Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz Mains switch-on frequency 200 (-10%) - 240 (+10%) Maximum of one time every 30 seconds Maximum of one time every 30 seconds Maximum of one time every 30 seconds Power section Overload current for 60 s every 600 s IL A 10.5 15.75 3.45 6.45 8.7 6.45 10.5 15.75 Starting current for 2 s IL A 12.25 18.38 4.03 7.53 10.15 7.53 12.25 18.38 Output voltage with Ve U2 Output Frequency f2 Switching frequency 115 V AC, single-phase 230 V AC, 3-phase 230 V AC, single-phase 230 V AC, single-phase 230 V AC, single-phase Hz 0 - 50 Hz (max. 120 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 120 Hz) 0 - 50 Hz (max. 120 Hz) 0 - 50 Hz (max. 120 Hz) fPWM kHz 16 (adjustable 4 - 32) Δf Hz 0.1 0.1 0.1 16 (adjustable 4 - 32) U/f control Slip compensation 0.1 16 (adjustable 4 - 32) Frequency resolution (setpoint value) 16 (adjustable 4 - 32) U/f control Slip compensation 0.1 0.1 0.1 0.1 Rated operational current Ie A 7 10.5 2.3 4.3 5.8 4.3 7 10.5 PV W 18.5 22 18.5 37.5 44 18.5 37.5 44 η % 95 96 95 95 96 95 95 96 IPE mA 2.49 2.49 <1 <1 <1 2.49 2.49 2.49 FS1 FS2 FS1 FS1 FS2 FS1 FS1 FS2 Operation Mode Power loss Heat dissipation at rated operational current Efficiency Maximum leakage current to ground (PE) without motor Frame size Motor feeder Assigned motor rating at 115 V, 50 Hz P kW 0.37 0.55 - - - - - - at 230 V, 50 Hz P kW - - 0.37 0.75 1.1 - - - 110 - 120 V, 60 Hz P HP 0.5 0.75 - - - - - - at 220 - 240 V, 60 Hz P HP - - 0.5 1 1.5 - - - Apparent power at rated operation 230 V S kVA 0 0 - - - 0.99 1.61 2.42 Apparent power at rated operation 240 V S kVA 0 0 - - - 1.03 1.68 2.52 Standard braking torque - - max. 30% MN max. 30% MN max. 30% MN - - - DC braking torque max. 100% of rated operational current Ie, variable Braking torque with external braking resistance - Apparent power Braking function max. 100% of rated operational current Ie, variable minimum external braking resistance Rmin Ω - max. 100% rated operational current Ie, with external braking resistance 47 - - - - max. 100% rated operational current Ie, with external braking resistance 47 - - max. 100% rated operational current Ie, with external braking resistance - - 47 Switch-on threshold for the braking transistor DC braking UDC V - - - - 390 V DC - - 390 V DC % I/Ie - - - - - - - - Braking torque % I/Ie - - - - - - - - External control voltage Uc V 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) Reference voltage Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) Control section Note CA04020001Z-EN-INT 1) With a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0 www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 50 PowerXL™ variable frequency drives PowerXL™ variable frequency drives DC1 (U (Ue: 230 VV AC, AC, single-phase, single-phase, UU2: 230VVAC, AC,33phase) phase) e: 230 2: 230 51 DC1DC1 (Ue:(Ue: 230 230 V AC,V single-phase, U2: 230 V AC, 3 phase) AC, 3 phase, U2: DC1 (Ue: 230 V AC, single-phase, U2: 230 V AC, 3 phase)DC1 (Ue: 230 V AC, 3 phase, U2: 230 V AC, 3 phase) DC1-122D3… DC1-124D3… DC1-127D0… DC1-12011… DC1-12015… DC1-322D3… DC1-324D3… DC1-327D0… DC1-32011… DC1-32018… DC1, DA1 Part no. General Climatic proofing ρw % Mounting position Altitude m Protection against direct contact < 95 %, average relative humidity (RH), non-condensing (EN 50178) < 95 %, average relative humidity (RH), non-condensing (EN 50178) Vertical Vertical 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase Radio interference level Radio interference class (EMC) Environment (EMC) longest permissible length of motor cable I m 25 (200) 25 (200) 25 (200) 25 (200) Main circuit Supply Rated operational voltage Ue 230 V AC, 1-phase 230 V AC, 3-phase Mains voltage (50/60Hz) ULN V 200 (-10%) - 240 (+10%) 200 (-10%) - 240 (+10%) Input current ILN T 5 8.5 13.9 19.5 30.5 3 4.5 7.3 11 18.8 Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz Mains switch-on frequency Maximum of one time every 30 seconds Maximum of one time every 30 seconds Power section Overload current for 60 s every 600 s IL A 3.45 6.45 10.5 15.75 22.5 3.45 6.45 10.5 15.75 27 Starting current for 2 s IL A 4.03 7.53 12.25 18.38 26.25 4.03 7.53 12.25 18.38 31.5 Output voltage with Ve U2 Output Frequency f2 Hz Switching frequency fPWM kHz 0 - 50 Hz (max. 500 Hz) 16 (adjustable 4 - 32) 0 - 50 Hz (max. 500 Hz) 16 (adjustable 4 - 32) 0 - 50 Hz (max. 500 Hz) 16 (adjustable 4 - 32) 0 - 50 Hz (max. 500 Hz) 8 (adjustable 4 - 24) Frequency resolution (setpoint value) Δf Rated operational current Ie 230 V AC, 3-phase 230 V AC, 3-phase 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 8 (adjustable 4 - 24) Hz 0 - 50 Hz 0 - 50 Hz (max. 500 Hz) (max. 500 Hz) 16 (adjustable 4 - 32) U/f control Slip compensation 0.1 0.1 0.1 0.1 0.1 0 - 50 Hz (max. 500 Hz) 16 (adjustable 4 - 32) U/f control Slip compensation 0.1 0.1 0.1 0.1 0.1 A 2.3 4.3 7 10.5 15 2.3 4.3 7 10.5 18 PV W 18.5 45.75 63 103.4 160 14.8 39.75 61.5 90.2 160 η % 95 93.9 95.8 95.3 96 96 94.7 95.9 95.9 96 IPE mA 2.49 2.49 2.49 2.49 <1 <1 <1 <1 <1 <1 FS1 FS1 FS2 FS2 FS3 FS1 FS1 FS2 FS2 FS3 Operation Mode Power loss Heat dissipation at rated operational current Efficiency Maximum leakage current to ground (PE) without motor Frame size Motor feeder Assigned motor rating at 230 V, 50 Hz P kW 0.37 0.75 1.5 2.2 4 0.37 0.75 1.5 2.2 4 at 220 - 240 V, 60 Hz P HP 0.5 1 2 3 5 0.5 1 2 3 5 Apparent power Apparent power at rated operation 230 V S kVA 0.92 1.71 2.79 4.18 5.98 0.92 1.71 2.79 4.18 7.17 Apparent power at rated operation 240 V S kVA 0.96 1.79 2.91 4.36 6.24 0.96 1.79 2.91 4.36 7.48 Standard braking torque max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN DC braking torque max. 100% of rated operational current Ie, variable Braking torque with external braking resistance - - max. 100% rated operational current Ie, with external braking resistance - max. 100% rated operational current Ie, with external braking resistance 47 max. 100% rated operational current Ie, with external braking resistance 47 Braking function max. 100% of rated operational current Ie, variable minimum external braking resistance Rmin Ω - - 100 47 47 - max. 100% rated operational current Ie, with external braking resistance 100 Switch-on threshold for the braking transistor DC braking UDC V - - 390 V DC 390 V DC 390 V DC - 390 V DC 390 V DC 390 V DC % I/Ie - - - - - - - - - Braking torque % I/Ie - - - - - - - - - External control voltage Uc V 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) Reference voltage Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) Control section Note CA04020001Z-EN-INT 1) With a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0 www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 52 PowerXL™ variable frequency drives PowerXL™ variable frequency drives DC1 (U (Ue: 400 VV AC, AC, 33 phase, phase, UU2: 400VVAC, AC,33phase) phase) e: 400 2: 400 53 DC1(Ue: (Ue: 400 400 VV AC, AC, 33 phase, phase, U2: U2: 400 V AC, 3 phase) DC1 DC1 (Ue: 400 V AC, 3 phase, U2: 400 V AC, 3 phase)DC1 (Ue: 400 V AC, 3 phase, U2: 400 V AC, 3 phase) DC1-342D2… DC1-344D1… DC1-345D8… DC1-349D5… DC1-34014… DC1-34018… DC1-34024… DC1, DA1 Part no. General Climatic proofing ρw % Mounting position Altitude m Protection against direct contact < 95 %, average relative humidity (RH), non-condensing (EN 50178) < 95 %, average relative humidity (RH), non-condensing (EN 50178) Vertical Vertical 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 380 (-10%) - 480 (+10%) 4.3 380 (-10%) - 480 (+10%) 6.1 380 (-10%) - 480 (+10%) 9.8 380 (-10%) - 480 (+10%) 380 (-10%) - 480 (+10%) 380 (-10%) - 480 (+10%) Radio interference level Radio interference class (EMC) Environment (EMC) longest permissible length of motor cable I m Main circuit Supply Rated operational voltage Ue Mains voltage (50/60Hz) ULN V Input current ILN T 380 (-10%) - 480 (+10%) 2.4 14.6 18.1 24.7 Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz Mains switch-on frequency Maximum of one time every 30 seconds Maximum of one time every 30 seconds Power section Overload current for 60 s every 600 s IL A 3.3 6.15 8.7 14.25 21 27 36 Starting current for 2 s IL A 3.85 7.18 10.15 16.63 24.5 31.5 42 Output voltage with Ve U2 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase Output Frequency f2 Hz 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) Switching frequency fPWM kHz 16 (adjustable 4 - 32) 16 (adjustable 4 - 32) 16 (adjustable 4 - 32) 8 (adjustable 4 - 24) Δf Hz 0.1 0.1 0.1 8 (adjustable 4 - 24) U/f control Slip compensation 0.1 8 (adjustable 4 - 24) Frequency resolution (setpoint value) 16 (adjustable 4 - 32) U/f control Slip compensation 0.1 0.1 0.1 Rated operational current Ie A 2.2 4.1 5.8 9.5 14 18 24 Heat dissipation at rated operational current Efficiency PV W 63.75 76.5 101.2 136 209 300 297 η % 91.5 94.9 95.4 96.6 96.2 97 97.3 Maximum leakage current to ground (PE) without motor Frame size IPE mA <1 <1 <1 <1 <1 <1 2.49 FS1 FS2 FS2 FS2 FS3 FS3 FS3 Operation Mode Power loss Motor feeder Assigned motor rating at 400 V, 50 Hz P kW 0.75 1.5 2.2 4 5.5 7.5 11 at 440 - 480 V, 60 Hz P HP 1 2 3 5 7.5 10 15 Apparent power at rated operation 400 V S kVA 1.52 2.84 4.02 6.58 9.67 12.47 16.63 Apparent power at rated operation 480 V S kVA 1.83 3.41 4.82 7.9 11.64 14.96 19.95 Standard braking torque max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN DC braking torque max. 100% of rated operational current Ie, variable max. 100% of rated operational current Ie, variable Braking torque with external braking resistance minimum external braking resistance - max. 100% rated operational current Ie, with external braking resistance max. 100% rated operational current Ie, with external braking resistance Apparent power Braking function Switch-on threshold for the braking transistor DC braking Braking torque External control voltage Reference voltage Rmin Ω - 200 200 100 100 47 47 UDC V - 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC % I/Ie - - - - - - - % I/Ie - - - - - - - Uc V 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) Control section Note CA04020001Z-EN-INT 1) With a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0 www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 54 PowerXL™ variable frequency drives PowerXL™ variable frequency drives DA1 (U phase) (Ue: 230 VV AC, AC, single-phase, single-phase, UU2: 230VVAC, AC,3single-phase) e: 230 2: 230 55 DA1(Ue: (Ue: 230 230 VV AC, AC, 33 phase, phase, U2: U2: 230 V AC, 3 phase) DA1 DA1 (Ue: 230 V AC, single-phase, U2: 230 V AC, single-phase)DA1 (Ue: 230 V AC, 3 phase, U2: 230 V AC, 3 phase) DA1-124D3… DA1-127D0… DA1-12011… DA1-324D3… DA1-327D0… DA1-32011… DA1-32018… DA1-32024… DC1, DA1 Typ General Climatic proofing ρw % Mounting position Altitude m Protection against direct contact < 95 %, average relative humidity (RH), non-condensing (EN 50178) < 95 %, average relative humidity (RH), non-condensing (EN 50178) Vertical Vertical 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 230 V AC, 1-phase 230 V AC, 1-phase 230 V AC, 1-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase Radio interference level Radio interference class (EMC) Environment (EMC) longest permissible length of motor cable I m Main circuit Supply Rated operational voltage Ue Mains voltage (50/60Hz) ULN V 200 (-10%) - 240 (+10%) 200 (-10%) - 240 (+10%) Input current ILN T 8.5 13.9 19.5 4.5 7.3 11 18.8 24.8 Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz Mains switch-on frequency Maximum of one time every 30 seconds Maximum of one time every 30 seconds Power section Overload current for 60 s every 600 s IL A 6.45 10.5 15.75 6.45 10.5 15.75 27 36 Starting current for 4 s IL A 8.6 14 21 8.6 14 21 36 48 Output voltage with Ve U2 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase Output Frequency f2 Hz 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) Switching frequency fPWM kHz 16 (adjustable 4 - 32) 16 (adjustable 4 - 24) 16 (adjustable 4 - 16) Δf Hz 0.1 16 16 (adjustable 4 - 32) (adjustable 4 - 32) U/f control Slip compensation sensorless vector control (SLV) Vector control with feedback (CLV) 0.1 0.1 16 (adjustable 4 - 32) Frequency resolution (setpoint value) 16 16 (adjustable 4 - 32) (adjustable 4 - 32) U/f control Slip compensation sensorless vector control (SLV) Vector control with feedback (CLV) 0.1 0.1 0.1 0.1 0.1 Rated operational current Ie A 4.3 7 10.5 4.3 7 10.5 18 24 PV W 45.75 63 103.4 39.75 61.5 90.2 160 170.5 η % 93.9 95.8 95.3 94.7 95.9 95.9 96 96.9 IPE mA 2.49 2.49 2.49 1.73 1.73 1.73 0.93 0.93 FS2 FS2 FS2 FS2 FS2 FS2 FS3 FS3 Operation Mode Power loss Heat dissipation at rated operational current Efficiency Maximum leakage current to ground (PE) without motor Frame size Motor feeder Assigned motor rating at 230 V, 50 Hz P kW 0.75 1.5 2.2 0.75 1.5 2.2 4 5.5 at 220 - 240 V, 60 Hz P HP 1 2 3 1 2 3 5 7.5 Apparent power Apparent power at rated operation 230 V S kVA 1.71 2.79 4.18 1.71 2.79 4.18 7.17 9.56 Apparent power at rated operation 240 V S kVA 1.79 2.91 4.36 1.79 2.91 4.36 7.48 9.98 Standard braking torque max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN DC braking torque max. 100% of rated operational current Ie, variable max. 100% of rated operational current Ie, variable Braking torque with external braking resistance minimum external braking resistance max. 100% rated operational current Ie, with external braking resistance max. 100% rated operational current Ie, with external braking resistance Braking function Rmin Ω 100 50 35 100 50 35 20 20 UDC V 390 V DC 390 V DC 390 V DC 390 V DC 390 V DC 390 V DC 390 V DC 390 V DC External control voltage Uc V 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) Reference voltage Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) Switch-on threshold for the braking transistor Control section Note CA04020001Z-EN-INT 1) With a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0 www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 56 PowerXL™ variable frequency drives PowerXL™ variable frequency drives DA1 (U (Ue: 400 VV AC, AC, 33 phase, phase, UU2: 400VVAC, AC,33phase) phase) e: 400 2: 400 57 DA1(Ue: (Ue: 400 400 VV AC, AC, 33 phase, phase, U2: U2: 400 V AC, 3 phase) DA1 DA1 (Ue: 400 V AC, 3 phase, U2: 400 V AC, 3 phase)DA1 (Ue: 400 V AC, 3 phase, U2: 400 V AC, 3 phase) DA1-342D2… DA1-344D1FB… DA1-345D8… DA1-349D5… DA1-34014… DA1-34018… DA1-34024… DA1-34030… DA1-34039… DA1-34046… DC1, DA1 Part no. General Climatic proofing ρw % Mounting position Altitude m Protection against direct contact < 95 %, average relative humidity (RH), non-condensing (EN 50178) < 95 %, average relative humidity (RH), non-condensing (EN 50178) Vertical Vertical 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase Radio interference level Radio interference class (EMC) Environment (EMC) longest permissible length of motor cable I m Main circuit Supply Rated operational voltage Ue Mains voltage (50/60Hz) ULN V 380 (-10%) - 480 (+10%) Input current ILN T 2.4 4.3 6.1 9.8 14.6 18.1 24.7 30.8 40 47.1 Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz Mains switch-on frequency 380 (-10%) - 480 (+10%) Maximum of one time every 30 seconds Maximum of one time every 30 seconds Power section Overload current for 60 s every 600 s IL A 3.3 6.15 8.7 14.25 21 27 36 45 58.5 69 Starting current for 4 s IL A 4.4 8.2 11.6 19 28 36 48 60 78 92 Output voltage with Ve U2 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase Output Frequency f2 Hz 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) Switching frequency fPWM kHz 8 (adjustable 4 - 32) 8 (adjustable 4 - 32) 8 (adjustable 4 - 24) 8 (adjustable 4 - 24) 8 (adjustable 4 - 24) Δf Hz 0.1 0.1 8 8 (adjustable 4 - 24) (adjustable 4 - 24) U/f control Slip compensation sensorless vector control (SLV) Vector control with feedback (CLV) 0.1 0.1 8 (adjustable 4 - 24) Frequency resolution (setpoint value) 8 8 (adjustable 4 - 24) (adjustable 4 - 24) U/f control Slip compensation sensorless vector control (SLV) Vector control with feedback (CLV) 0.1 0.1 0.1 0.1 0.1 0.1 Rated operational current Ie A 2.2 4.1 5.8 9.5 14 18 24 30 39 46 PV W 63.75 76.5 101.2 136 209 300 297 375 444 506 η % 91.5 94.9 95.4 96.6 96.2 97 97.3 97.5 97.6 97.7 IPE mA 4.65 4.65 4.65 4.65 1.55 1.55 2.47 2.47 2.47 2.47 FS2 FS2 FS2 FS2 FS3 FS3 FS4 FS4 FS4 FS4 Operation Mode Power loss Heat dissipation at rated operational current Efficiency Maximum leakage current to ground (PE) without motor Frame size Motor feeder Assigned motor rating at 400 V, 50 Hz P kW 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 at 440 - 480 V, 60 Hz P HP 1 2 3 5 7.5 10 15 20 25 30 Apparent power Apparent power at rated operation 400 V S kVA 1.52 2.84 4.02 6.58 9.67 12.47 16.63 20.78 27.02 31.87 Apparent power at rated operation 480 V S kVA 1.83 3.41 4.82 7.9 11.64 14.96 19.95 24.94 32.42 38.24 Standard braking torque max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN DC braking torque max. 100% of rated operational current Ie, variable max. 100% of rated operational current Ie, variable Braking torque with external braking resistance minimum external braking resistance max. 100% rated operational current Ie, with external braking resistance max. 100% rated operational current Ie, with external braking resistance Braking function Rmin Ω 400 200 150 100 75 50 40 22 22 22 UDC V 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC External control voltage Uc V 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) Reference voltage Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) Switch-on threshold for the braking transistor Control section Note CA04020001Z-EN-INT 1) With a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0 www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 58 PowerXL™ variable frequency drives PowerXL™ variable frequency drives DA1 (U (Ue: 230 VV AC, AC, 33 phase, phase, UU2: 230VVAC, AC,33phase) phase) e: 400 2: 400 59 DA1(Ue: (Ue: 230 400 VV AC, AC, 33 phase, phase, U2: U2: 230 400 V AC, 3 phase) DA1 DA1 (Ue: 230 V AC, 3 phase, U2: 230 V AC, 3 phase)DA1 (Ue: 230 V AC, 3 phase, U2: 230 V AC, 3 phase) DA1-34090… DC1, DA1 Part no. General Climatic proofing ρw % Mounting position Altitude m Protection against direct contact < 95 %, average relative humidity (RH), non-condensing (EN 50178) < 95 %, average relative humidity (RH), non-condensing (EN 50178) Vertical Vertical 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase Radio interference level Radio interference class (EMC) Environment (EMC) longest permissible length of motor cable I m Main circuit Supply Rated operational voltage Ue Mains voltage (50/60Hz) ULN V 380 (-10%) - 480 (+10%) Input current ILN T 62.8 73.8 92.2 112.5 153.2 183.7 205.9 244.5 307.8 Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz Mains switch-on frequency 380 (-10%) - 480 (+10%) Maximum of one time every 30 seconds Maximum of one time every 30 seconds Power section Overload current for 60 s every 600 s IL A 91.5 105 135 165 225 270 303 360 453 Starting current for 4 s IL A 122 140 180 220 300 360 404 480 604 Output voltage with Ve U2 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase Output Frequency f2 Hz 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) Switching frequency fPWM kHz 4 (adjustable 4 - 16) 4 (adjustable 4 - 16) 4 (adjustable 4 - 12) 4 (adjustable 4 - 8) Δf Hz 0.1 0.1 4 4 (adjustable 4 - 12) (adjustable 4 - 8) U/f control Slip compensation sensorless vector control (SLV) Vector control with feedback (CLV) 0.1 0.1 4 (adjustable 4 - 16) Frequency resolution (setpoint value) 8 8 (adjustable 4 - 24) (adjustable 4 - 24) U/f control Slip compensation sensorless vector control (SLV) Vector control with feedback (CLV) 0.1 0.1 0.1 0.1 0.1 Rated operational current Ie A 61 72 90 110 150 180 202 240 302 PV W 840 925 1080 1210 1575 1800 2090 2376 3040 η % 97.2 97.5 97.6 97.8 97.9 98 98.1 98.2 98.1 IPE mA 0.49 0.49 2.68 2.68 2.68 2.68 4.75 4.75 4.75 FS5 FS5 FS6 FS6 FS6 FS6 FS7 FS7 FS7 Operation Mode Power loss Heat dissipation at rated operational current Efficiency Maximum leakage current to ground (PE) without motor Frame size Motor feeder Assigned motor rating at 400 V, 50 Hz P kW 30 37 45 55 75 90 110 132 160 at 440 - 480 V, 60 Hz P HP 40 50 60 75 100 150 175 200 250 Apparent power Apparent power at rated operation 400 V S kVA 42.26 48.5 62.35 76.21 103.92 124.71 139.95 166.28 209.23 Apparent power at rated operation 480 V S kVA 50.71 58.2 74.82 91.45 124.71 149.65 167.94 199.53 251.08 Standard braking torque max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN DC braking torque max. 100% of rated operational current Ie, variable max. 100% of rated operational current Ie, variable Braking torque with external braking resistance minimum external braking resistance max. 100% rated operational current Ie, with external braking resistance max. 100% rated operational current Ie, with external braking resistance Braking function Rmin Ω 12 12 6 6 6 6 6 6 6 UDC V 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC 780 V DC External control voltage Uc V 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) Reference voltage Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) Switch-on threshold for the braking transistor Control section Note CA04020001Z-EN-INT 1) With a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0 www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 60 PowerXL™ variable frequency drives PowerXL™ variable frequency drives DA1 (U (Ue: 230 VV AC, AC, 33 phase, phase, UU2: 230VVAC, AC,33phase) phase) e: 230 2: 230 DA1-32039… DA1-32046… DA1-32061… DA1-32072… DA1-32090… DA1-32110… DA1-32150… DA1-32180… DA1-32202… DA1-32248… DC1, DA1 Typ 61 DA1(Ue: (Ue: 230 230 VV AC, AC, 33 phase, phase, U2: U2: 230 V AC, 3 phase) DA1 General Climatic proofing ρw % < 95 %, average relative humidity (RH), non-condensing (EN 50178) < 95 %, average relative humidity (RH), non-condensing (EN 50178) Vertical Vertical 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 4000 m BGV A3 (VBG4, finger- and back-of-hand proof) C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments m 25 (200) Mounting position Altitude m Protection against direct contact Radio interference level Radio interference class (EMC) Environment (EMC) longest permissible length of motor cable I 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 25 (200) 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 200 (-10%) - 240 (+10%) 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase Main circuit Supply Rated operational voltage Ue Mains voltage (50/60Hz) ULN V 230 V AC, 230 V AC, 3-phase 3-phase 200 (-10%) - 240 (+10%) Input current ILN T 40 47.1 62.4 74.1 92.3 112.7 153.5 183.8 206.2 252.8 Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz 48 - 62 Hz Mains switch-on frequency Maximum of one time every 30 seconds Maximum of one time every 30 seconds Power section Overload current for 60 s every 600 s IL A 45 69 91.5 108 135 165 225 270 303 372 Starting current for 4 s IL A 60 92 122 144 180 220 300 360 404 496 Output voltage with Ve U2 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase 230 V AC, 3-phase Output Frequency f2 Hz Switching frequency fPWM kHz 0 - 50 Hz (max. 500 Hz) 4 (adjustable 4 - 8) 0 - 50 Hz (max. 500 Hz) 4 (adjustable 4 - 16) 0 - 50 Hz (max. 500 Hz) 4 (adjustable 4 - 12) Frequency resolution (setpoint value) Δf Rated operational current Ie 230 V AC, 3-phase 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 0 - 50 Hz (max. 500 Hz) 4 (adjustable 4 - 16) Hz 0 - 50 Hz 0 - 50 Hz (max. 500 Hz) (max. 500 Hz) 8 (adjustable 4 - 24) U/f control Slip compensation sensorless vector control (SLV) Vector control with feedback (CLV) 0.1 0.1 0.1 0.1 0.1 0 - 50 Hz 0 - 50 Hz (max. 500 Hz) (max. 500 Hz) 4 4 (adjustable 4 - 16) (adjustable 4 - 12) U/f control Slip compensation sensorless vector control (SLV) Vector control with feedback (CLV) 0.1 0.1 0.1 0.1 0.1 A 39 46 61 72 90 110 150 180 202 248 PV W 187.5 264 345 518 550 720 814 945 1100 1425 η % 97.5 97.6 97.7 97.2 97.5 97.6 97.8 97.9 98 98.1 IPE mA 1.42 1.42 0.28 0.28 1.54 1.54 1.54 1.54 2.74 2.74 FS4 FS4 FS5 FS5 FS6 FS6 FS6 FS6 FS7 FS7 Operation Mode Power loss Heat dissipation at rated operational current Efficiency Maximum leakage current to ground (PE) without motor Frame size Motor feeder Assigned motor rating at 230 V, 50 Hz P kW 7.5 11 15 18.5 22 30 45 55 55 75 at 220 - 240 V, 60 Hz P HP 10 15 20 25 30 40 50 60 75 100 Apparent power Apparent power at rated operation 230 V S kVA 11.95 18.33 24.3 28.68 35.85 43.82 59.76 71.71 80.47 98.8 Apparent power at rated operation 240 V S kVA 12.47 19.12 25.36 29.93 37.41 45.73 62.35 74.82 83.97 103.09 Standard braking torque max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN max. 30% MN DC braking torque max. 100% of rated operational current Ie, variable max. 100% of rated operational current Ie, variable Braking torque with external braking resistance minimum external braking resistance max. 100% rated operational current Ie, with external braking resistance max. 100% rated operational current Ie, with external braking resistance Braking function Rmin Ω 22 12 12 6 6 6 6 6 6 6 UDC V 390 V DC 390 V DC 390 V DC 390 V DC 390 V DC 390 V DC 390 V DC 390 V DC 390 V DC 390 V DC External control voltage Uc V 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) 24 V DC (max. 100 mA) Reference voltage Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) Switch-on threshold for the braking transistor Control section Note CA04020001Z-EN-INT 1) With a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0 www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 62 PowerXL™ variable frequency drives Mains chokes, motor chokes Technical data Mains chokes, motor chokes DX-LN1… DX-LN3… DX-LM3… IEC/EN 61558-2-20-2000, VDE 0570 Part 2-20/2001-04, UL, CSA -25 to +40, up to 70 with current derating (see the note) -25 - +85 IEC/EN 61558-2-20-2000, VDE 0570 Part 2-20/2001-04, UL, CSA -25 to +40, up to 70 with current derating (see the note) -25 - +85 IEC/EN 61558-2-20-2000, VDE 0570 Part 2-20/2001-04, UL, CSA -25 to +40, up to 70 with current derating (see the note) -25 - +85 11 ms2/15 3 shocks 1 (0 - 150 Hz) 11 ms2/15 3 shocks 1 (0 - 150 Hz) 11 ms2/15 3 shocks 1 (0 - 150 Hz) 0.35 mm at 10 - 55 Hz 0.35 mm at 10 - 55 Hz 0.35 mm at 10 - 55 Hz 0 – 1000 above sea level, up to 5000 with current reduction (see notes) Standing vertically, suspended horizontally < 50 0 – 1000 above sea level, up to 5000 with current reduction (see notes) Standing vertically, suspended horizontally < 50 0 – 1000 above sea level, up to 5000 with current reduction (see notes) Standing vertically, suspended horizontally < 50 General Standards Operating temperature °C Storage temperature ϑ °C Mechanical shock resistance g Vibration resistance g Vibration Altitude m Mounting position Free surrounding areas MM Protection type IP20 (terminal) IP20 (terminal) IP20 (terminal) Rated duty factor % DF 100 100 100 Weight kg 0.7 1.5 1.5 Electrical data Rated operational voltage Max. supply voltage Operating frequency f Insulation class 1 AC 230 V 3 AC 400 V 3 AC 400 V V AC 260 V + 0% (50/60 Hz) 550 V + 0% (50/60 Hz) 750 V + 0% (50/60 Hz) Hz 50/60 50/60 0…200 B B B Connection Terminations ✓ ✓ ✓ Connection lugs - ✓ (≧ 50 A) ✓ (≧ 63 A) PE stud ✓ ✓ ✓ CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 63 Mains chokes, motor chokes Part no. Inductance Cu factor L Maximum heat dissipatio n Pv Voltage sag Connection Drilling Tightening torque Weight Ie Uk Terminal Terminal AWG Connection lug mm2 A mH W kg % mm2 mm Nm kg Rated operational voltage 1 AC 230 V DX-LN1-006 5.8 5.05 DX-LN1-009 8.6 3.41 9 0,09 4 11 0,11 4 4 20 - 10 - - 0.8 0.7 4 20 - 10 - - 0.8 DX-LN1-013 13 2.25 12 0,18 0.7 4 4 20 - 10 - - 0.8 DX-LN1-018 18 1.63 17 1.5 0,27 4 4 20 - 10 - - 0.8 DX-LN1-024 24 1.22 1.5 20 0,33 4 4 20 - 10 - - 0.8 DX-LN1-032 32 2 0.92 24 0,00 4 4 20 - 10 - 0 0.8 3 Rated operational voltage 3 AC 400 V DX-LN3-004 3.9 7.51 17 0,25 4 4 20 - 10 - - 0.8 1.5 DX-LN3-006 6 4.9 19 0,34 4 4 20 - 10 - - 0.8 1.5 DX-LN3-010 10 2.94 33 0,45 4 4 20 - 10 - - 0.8 2.2 DX-LN3-016 16 1.84 44 0,53 4 4 20 - 10 - - 0.8 2.9 DX-LN3-025 25 1.18 57 0,90 4 4 20 - 10 - - 0.8 4.8 DX-LN3-040 40 0.64 59 0,91 2.5 10 20 - 6 - - 1.5 4.8 DX-LN3-050 50 0.37 58 1,08 2.5 - - Cu 15 x 2 7 3 5.9 DX-LN3-060 60 0.31 60 1,51 2.5 - - Cu 15 x 2 7 3 5.9 DX-LN3-080 80 0.23 86 1,67 2.5 - - Cu 20 x 3 9 6 7.3 DX-LN3-100 100 0.18 101 1,68 2.5 - - Cu 20 x 3 9 6 10.2 DX-LN3-120 120 0.15 100 2,26 2.5 - - Cu 25 x 5 11 10 10.2 DX-LN3-160 160 0.11 140 2,35 2.5 - - Cu 25 x 5 11 10 12.3 DX-LN3-200 200 0.09 154 3,81 2.5 - - Cu 25 x 5 11 10 14.9 DX-LN3-250 250 0.07 155 4,26 2.5 - - Cu 40 x 5 14 15.5 20.6 DX-LN3-300 300 0.06 196 4,28 2.5 - - Cu 40 x 5 14 15.5 20.6 DX-LN3-303 303 0.06 230 0,00 2.5 - - Cu 40 x 5 14 15.5 20.6 DX-LN3-370 370 0.05 290 0,00 2.5 - - Cu 40 x 5 14 15.5 24.3 DX-LN3-450 450 0.04 300 0,00 2.5 - - Cu 40 x 10 14 15.5 23.8 Part no. Rated operational current Inductance max. heat dissipation (pulse frequency) Drilling Tightening torque Weight DC1, DA1 Rated operational current Mains choke (3 kHz) (5 kHz) (12 kHz) Cu factor Connection Terminal Terminal Connection lug Ie L Pv Pv Pv A mH W W W kg mm2 AWG mm2 mm Nm kg Rated operational voltage 3 AC 400 V 5 2 DX-LM3-005 12 14 24 0,29 4 20 - 10 - - 0.8 1.5 DX-LM3-008 8 4.1 32 46 54 1,09 4 20 - 10 - - 0.8 4.8 DX-LM3-011 11 3 45 66 71 1,23 4 20 - 10 - - 0.8 4.8 DX-LM3-016 16 1.5 50 75 78 0,88 4 20 - 10 - - 0.8 4.8 DX-LM3-035 35 1 75 114 116 2,30 4 20 - 10 - - 0.8 7.3 DX-LM3-050 50 0.6 110 157 168 3,60 10 20 - 6 - - 1.5 12.3 DX-LM3-063 63 0.5 130 190 193 3,01 - - Cu 15 x 2 7 3 14.9 DX-LM3-080 80 0.5 132 206 206 5,88 - - Cu 20 x 2 9 6 20.6 DX-LM3-100 100 0.45 177 279 294 10,10 - - Cu 20 x 2 9 6 31 DX-LM3-150 150 0.35 293 418 424 8,22 - - Cu 25 x 5 11 10 45 DX-LM3-180 180 0.3 418 298 439 14,75 - - Cu 25 x 5 11 10 45 DX-LM3-220 220 0.2 344 512 517 11,37 - - Cu 40 x 5 14 15.5 45 DX-LM3-260 260 0.15 358 526 520 11,10 - - Cu 40 x 5 14 15.5 45 DX-LM3-303 303 0.15 685 - - 0,00 - - Cu 40 x 5 14 15.5 48.7 DX-LM3-370 370 0.12 685 - - 0,00 - - Cu 40 x 5 14 15.5 61.7 DX-LM3-450 450 0.1 730 - - 0,00 - - Cu 40 x 10 14 15.5 81.7 Motor chokes CA04020001Z-EN-INT www.eaton.eu 64 PowerXL™ variable frequency drives DC1 Dimensions DC1 b2 DC1, sizes FS1 - FS3, degree of protection IP20/NEMA 0 ⌀ ⌀1 b1 b ⌀2 EMC VAR 1 2 3 4 5 6 7 8 9 10 11 a1 a a mm (inch) 81 (3.19) 107 (4.21) 131 (5.16) c1 c a1 mm (inch) 50 (1.97) 75 (2.95) 100 (3.94) b mm (inch) 184 (7.24) 231 (9.09) 273 (10.75) b1 mm (inch) 170 (6.69) 215 (8.46) 255 (10.04) b2 mm (inch) 7 (0.28) 8 (0.31) 8.5 (0.33) c mm (inch) 124 (4.88) 152 (5.98) 175 (6.89) c1 mm (inch) 4 (0.16) 5 (0.2) 5 (0.2) ⌀1 mm (inch) 6 (0.24) 6 (0.24) 6 (0.24) ⌀2 mm (inch) 12 (0.47) 12 (0.47) 12 (0.47) Weight kg 1.1 2.6 4 Size FS1 FS2 FS3 DC1, sizes FS1 - FS3, degree of protection IP66/NEMA 4X ⌀1 b2 b1 b1 b ⌀2 a1 a1 a a mm (inch) 161 (6.34) 188 (7.4) 210.5 (8.29) a1 mm (inch) 148.5 (5.85) 176 (6.93) 197.5 (7.78) CA04020001Z-EN-INT c1 c b mm (inch) 232 (9.13) 257 (10.12) 310 (12.2) www.eaton.eu b1 mm (inch) 189 (7.44) 200 (7.87) 251.5 (9.9) b2 mm (inch) 25 (0.98) 28.5 (1.12) 33.4 (1.31) c mm (inch) 184 (7.24) 192 (7.56) 234 (9.21) c1 mm (inch) 3.5 (0.14) 3.5 (0.14) 3.5 (0.14) ⌀1 mm (inch) 4 (0.15) 4.2 (0.16) 4.2 (0.16) ⌀2 mm (inch) 8 (0.31) 8.5 (0.33) 8.5 (0.33) Weight kg (lbs) 2.5 (5.51) 4.7 (10.36) 7.9 (17.42) Size FS1 FS2 FS3 PowerXL™ variable frequency drives 65 DC1, DA1 DC1, DA1 DC1, DA1 DC1, sizes FS1 - FS3, degree of protection IP66/NEMA 4X, with local controls ⌀1 0 REV ⌀2 FWD OFF PWR b2 b1 b1 b ON a1 c1 a1 a a mm (inch) 161 (6.34) 188 (7.4) 210.5 (8.29) a1 mm (inch) 148.5 (5.85) 176 (6.93) 197.5 (7.78) c b mm (inch) 232 (9.13) 257 (10.12) 310 (12.2) b1 mm (inch) 189 (7.44) 200 (7.87) 251.5 (9.9) b2 mm (inch) 25 (0.98) 28.5 (1.12) 33.4 (1.31) c mm (inch) 184 (7.24) 192 (7.56) 234 (9.21) c1 mm (inch) 3.5 (0.14) 3.5 (0.14) 3.5 (0.14) ⌀1 mm (inch) 4 (0.15) 4.2 (0.16) 4.2 (0.16) ⌀2 mm (inch) 8 (0.31) 8.5 (0.33) 8.5 (0.33) Weight kg (lbs) 2.8 (6.17) 5 (11.02) 8.2 (18.08) Size FS1 FS2 FS3 b2 DA1, sizes FS2 - FS3, degree of protection IP20/NEMA 0 ⌀ ⌀1 DC- L1/L L2/N L3 ⌀2 EMC b1 b VAR 1 2 3 4 5 6 7 8 9 10 11 12 13 COM 14 15 16 17 18 DC+ BR U V W a1 a a mm (inch) 107 (4.21) 131 (5.16) a1 mm (inch) 75 (2.95) 100 (3.94) c1 c b mm (inch) 231 (9.09) 273 (10.75) b1 mm (inch) 215 (8.46) 255 (10.04) b2 mm (inch) 8 (0.31) 8.5 (0.33) c mm (inch) 186 (7.32) 204 (8.03) c1 mm (inch) 5 (0.2) 5 (0.2) ⌀1 mm (inch) 6 (0.24) 6 (0.24) ⌀2 mm (inch) 12 (0.47) 12 (0.47) Weight kg 1.8 3.5 Size FS2 FS3 CA04020001Z-EN-INT www.eaton.eu 66 PowerXL™ variable frequency drives DA1 DA1 DA1, sizes FS2 - FS3, degree of protection IP66/NEMA 4X ⌀1 b2 b1 b1 b ⌀2 a1 c a1 a a mm (inch) 188 (7.4) 211 (8.29) a1 mm (inch) 176 (6.93) 198 (7.78) b mm (inch) 257 (10.12) 310 (12.2) b1 mm (inch) 200 (7.87) 252 (9.9) b2 mm (inch) 20 (0.79) 25 (0.98) c mm (inch) 239.3 (9.42) 266.3 (10.48) ⌀1 mm (inch) 4.2 (0.16) 4.2 (0.16) ⌀2 mm (inch) 8.5 (0.33) 8.5 (0.33) Weight kg (lbs) 4.5 (10.4) 7 (15.9) Size FS2 FS3 DA1, sizes FS2 - FS3, degree of protection IP66/NEMA 4X, with local controls ⌀1 ⌀2 0 REV PWR FWD OFF b2 b1 b1 b ON a1 c a1 a a mm (inch) 188 (7.4) 211 (8.29) a1 mm (inch) 176 (6.93) 198 (7.78) CA04020001Z-EN-INT b mm (inch) 257 (10.12) 310 (12.2) www.eaton.eu b1 mm (inch) 200 (7.87) 252 (9.9) b2 mm (inch) 20 (0.79) 25 (0.98) c mm (inch) 239.3 (9.42) 266.3 (10.48) ⌀1 mm (inch) 4.2 (0.16) 4.2 (0.16) ⌀2 mm (inch) 8.5 (0.33) 8.5 (0.33) Weight kg (lbs) 4.8 (10.6) 7.3 (16.1) Size FS2 FS3 PowerXL™ variable frequency drives 67 DA1 ⌀ DC1, DA1 b2 DA1, sizes FS4 - FS7, degree of protection IP55 ⌀1 b1 b ⌀2 a1 a a mm (inch) 171 (6.73) 235 (9.25) 330 (12.99) 330 (12.99) a1 mm (inch) 110 (4.33) 175 (6.89) 200 (7.87) 200 (7.87) c1 c b mm (inch) 450 (17.72) 540 (20.28) 865 (34.06) 1280 (50.39) b1 mm (inch) 428 (16.85) 515 (20.28) 840 (33.07) 1255 (44.41) b2 mm (inch) 9 (0.35) 12 (0.47) 15 (0.59) 15 (0.59) c mm (inch) 240 (9.45) 270 (10.63) 330 (12.99) 360 (14.17) c1 mm (inch) 2 (0.08) 2 (0.08) 2 (0.08) 2 (0.08) ⌀1 mm (inch) 8 (0.31) 8 (0.31) 11 (0.43) 11 (0.43) ⌀2 mm (inch) 15 (0.59) 15 (0.59) 22 (0.87) 22 (0.87) Weight kg 11.5 22.5 50 80 b2 mm (inch) 33 (1.3) c mm (inch) 516 (20.31) c1 mm (inch) 2 (0.08) ⌀1 mm (inch) 18 (0.71) ⌀2 mm (inch) 35 (1.38) Weight kg 270 Size FS4 FS5 FS6 FS7 DA1, size FS8, degree of protection IP40 Control panel version a mm (inch) 500 (19.69) a1 mm (inch) 350 (13.78) b mm (inch) 2000 (78.74) b1 mm (inch) 1950 (76.77) Size FS8 CA04020001Z-EN-INT www.eaton.eu 68 PowerXL™ variable frequency drives Accessories Accessories Expansion modules for DC1 56 mm (2.2") 39 mm (1.54") 41 mm (1.61") 56 mm (2.2") 39 mm (1.54") 41 mm (1.61") 18 mm (0.71") DXC-EXT-2RO 12.3 mm (0.48") DXC-EXT-LOCSIM 27 mm (1.06") 36 mm (1.42") 56 mm (2.2") Expansion modules for DA1 21 mm (0.83") 23 mm (0.91") DXA-EXT-3DI1RO DXA-EXT-3RO DXA-EXT-ENCOD 41 mm (1.61") 48 mm (1.89") 33.7 mm (1.33") 60 mm (2.36") 70 mm (2.75") Fieldbus module for DA1 OP ST PROFIBUS DP-V1 41 mm (1.61") 48 mm (1.89") CA04020001Z-EN-INT www.eaton.eu 22.3 mm (0.88") DX-NET-PROFIBUS 33.7 mm (1.33") 51.8 mm (2.04") 24 mm (0.95") 18 mm (0.71") DXC-EXT-IO110 DXC-EXT-IO230 DXC-EXT-2RO1AO PowerXL™ variable frequency drives 69 Accessories External keypad DC1, DA1 DX-KEY-OLED 110 mm (4.33") 81 mm (3.19") DX-KEY-LED Hand 66 mm (2.6") 26 mm (1.02") Auto 4 mm (0.16") 90 mm (3.54") 23.5 mm (0.93") 4.5 mm (0.18") Cable and splitter 19 mm (0.75") DX-SPL-RJ45-2SL1PL 42 mm (1.65") 145 mm (5.7") Interface converter DX-COM-PCKIT USB 6 5 4 3 2 1 RxD TxD SW 77 mm (3.03") PWR Serial 81 mm (3.19") 23 mm (0.91") CA04020001Z-EN-INT www.eaton.eu 70 PowerXL™ variable frequency drives Mains chokes, motor chokes Mains chokes, motor chokes Mains chokes DX-LN1-… 1 2 c1 ± 5 mm (c1 ± 0.20”) c ± 5 mm (c ± 0.20”) PE od a1 b1 b2 a b ± 5 mm (b ± 0.20”) DX-LN1-006 DX-LN1-009 DX-LN1-013 DX-LN1-018 DX-LN1-024 DX-LN1-032 a mm (inch) 66 (2.6) 66 (2.6) 84 (3.31) 84 (3.31) 84 (3.31) 105 (4.13) a1 mm (inch) 50 (1.97) 50 (1.97) 64 (2.52) 64 (2.52) 64 (2.52) 84 (3.31) b mm (inch) 71 (2.8) 71 (2.8) 67 (2.64) 67 (2.64) 81 (3.19) 102 (4.02) b1 mm (inch) 44 (1.73) 44 (1.73) 47 (1.85) 47 (1.85) 61 (2.4) 65 (2.56) b2 mm (inch) 55 (2.17) 55 (2.17) 60 (2.36) 60 (2.36) 74 (2.91) 81 (3.19) c mm (inch) 80 (3.15) 80 (3.15) 90 (3.54) 90 (3.54) 90 (3.54) 121 (4.76) c1 mm (inch) 61 (2.36) 61 (2.36) 75 (2.95) 75 (2.95) 75 (2.95) 94 (3.7) d mm (inch) 4.5 x 8 (0.18 x 0.31) 4.5 x 8 (0.18 x 0.31) 4.8 x 8 (0.18 x 0.31) 4.8 x 8 (0.18 x 0.31) 4.8 x 8 (0.18 x 0.31) 5.8 x 11 (0.23 x 0.43) Weight kg 0.7 0.7 1.5 1.5 2 3 Mains chokes, motor chokes DX-LN3-004…-DX-LN3-040 DX-LM3-005…-DX-LM3-050 U1 U2 V1 V2 W1W2 c1 ± 5 mm (c1 ± 0.20”) PE c ± 5 mm (c ± 0.20”) PE od a1 b1 a b2 b ± 5 mm (b ± 0.20”) DX-LN3-004 DX-LN3-006 DX-LN3-010 DX-LN3-016 DX-LN3-025 DX-LN3-040 DX-LM3-005 DX-LM3-008 DX-LM3-011 DX-LM3-016 DX-LM3-035 DX-LM3-050 a mm (inch) 115 (4.53) 115 (4.53) 140 (5.51) 140 (5.51) 195 (7.68) 195 (7.68) 115 (4.53) 195 (7.68) 195 (7.68) 195 (7.68) 220 (8.66) 270 (10.63) CA04020001Z-EN-INT a1 mm (inch) 100 (3.94) 100 (3.94) 125 (4.92) 125 (4.92) 175 (6.89) 175 (6.89) 100 (3.94) 175 (6.89) 175 (6.89) 175 (6.89) 200 (7.87) 250 (9.84) www.eaton.eu b mm (inch) 66 (2.6) 66 (2.6) 61 (2.4) 71 (2.8) 104 (4.09) 104 (4.09) 66 (2.6) 104 (4.09) 104 (4.09) 104 (4.09) 132 (5.2) 106 (4.17) b1 mm (inch) 50 (1.97) 50 (1.97) 50 (1.97) 50 (1.97) 50 (1.97) 50 (1.97) 50 (1.97) 50 (1.97) 50 (1.97) 50 (1.97) 75 (2.95) 75 (2.95) b2 mm (inch) 66 (2.6) 66 (2.6) 61 (2.4) 71 (2.8) 76.5 (3.01) 76.5 (3.01) 66 (2.6) 76.5 (3.01) 76.5 (3.01) 76.5 (3.01) 101.5 (4) 96 (3.78) c mm (inch) 118 (4.65) 118 (4.65) 138 (5.43) 138 (5.43) 175 (6.89) 188 (7.4) 118 (4.65) 175 (6.89) 175 (6.89) 175 (6.89) 195 (7.68) 228 (8.98) c1 mm (inch) 84 (3.31) 84 (3.31) 105 (4.13) 105 (4.13) 134 (5.28) 134 (5.28) 84 (3.31) 134 (5.28) 134 (5.28) 134 (5.28) 160 (6.3) 198 (7.8) d mm (inch) 5 x 10 (0.2 x 0.39) 5 x 10 (0.2 x 0.39) 5 x 10 (0.2 x 0.39) 5 x 10 (0.2 x 0.39) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) 5 x 10 (0.2 x 0.39) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) Weight kg 1.5 1.5 2.2 2.9 4.8 4.8 1.5 4.8 4.8 4.8 7.3 12.3 PowerXL™ variable frequency drives 71 Mains chokes, motor chokes Mains chokes, motor chokes Mains chokes, motor chokes PE U1 V1 W1 U2 V2 W2 U2 V2 W2 c ± 5 mm (c ± 0.20”) PE DC1, DA1 DX-LN3-050…-DX-LN3-450 DX-LM3-063…-DX-LM3-450 a1 ⌀d b1 a b2 b ± 10 mm (b ± 0.39”) Height tolerance depends on gap The position of connection lugs U2-V2-W2 depends on the coil material and can deviate from the position illustrated here. DX-LN3-050 DX-LN3-060 DX-LN3-080 DX-LN3-100 DX-LN3-120 DX-LN3-160 DX-LN3-200 DX-LN3-250 DX-LN3-300 DX-LN3-303 DX-LN3-370 DX-LN3-450 DX-LM3-063 DX-LM3-080 DX-LM3-100 DX-LM3-150 DX-LM3-180 DX-LM3-220 DX-LM3-260 DX-LM3-303 DX-LM3-370 DX-LM3-450 a mm (inch) 195 (7.68) 195 (7.68) 220 (8.66) 220 (8.66) 220 (8.66) 270 (10.63) 270 (10.63) 270 (10.63) 270 (10.63) 270 (10.63) 384 (15.12) 384 (15.12) 270 (10.63) 270 (10.63) 384 (15.12) 384 (15.12) 384 (15.12) 384 (15.12) 384 (15.12) 454 (17.87) 454 (17.87) 454 (17.87) a1 mm (inch) 175 (6.89) 175 (6.89) 200 (7.87) 200 (7.87) 200 (7.87) 250 (9.84) 250 (9.84) 250 (9.84) 250 (9.84) 250 (9.84) 350 (13.78) 350 (13.78) 250 (9.84) 250 (9.84) 350 (13.78) 350 (13.78) 350 (13.78) 350 (13.78) 350 (13.78) 425 (16.73) 425 (16.73) 425 (16.73) b mm (inch) 105 (4.13) 105 (4.13) 110 (4.33) 130 (5.12) 130 (5.12) 125 (4.92) 155 (6.1) 155 (6.1) 155 (6.1) 155 (6.1) 215 (8.46) 215 (8.46) 155 (6.1) 155 (6.1) 215 (8.46) 260 (10.24) 260 (10.24) 260 (10.24) 260 (10.24) 270 (10.63) 285 (11.22) 300 (11.81) b1 mm (inch) 75 (2.95) 75 (2.95) 50 (1.97) 75 (2.95) 75 (2.95) 75 (2.95) 100 (3.94) 100 (3.94) 100 (3.94) 100 (3.94) 100 (3.94) 100 (3.94) 100 (3.94) 100 (3.94) 100 (3.94) 150 (5.91) 150 (5.91) 150 (5.91) 150 (5.91) 100 (3.94) 125 (4.92) 150 (5.9) b2 mm (inch) 91.5 (3.6) 91.5 (3.6) 81.5 (3.21) 101.5 (4) 101.5 (4) 96 (3.75) 120 (4.72) 125 (4.92) 125 (4.92) 125 (4.92) 130 (5.12) 130 (5.12) 120 (4.72) 125 (4.92) 130 (5.12) 180 (7.09) 180 (7.09) 180 (7.09) 180 (7.09) 150 (5.9) 165 (6.5) 180 (7.09) c mm (inch) 132 ±5 (5.2 ±0.2) 132 ±5 (5.2 ±0.2) 160 ±5 (6.3 ±0.2) 160 ±5 (6.3 ±0.2) 160 ±5 (6.3 ±0.2 ) 200 ±5 (7.87 ±0.2) 202 ±5 (7.95 ±0.2) 210 ±5 (8.27 ±0.2) 210 ±5 (8.27 ±0.2) 210 ±5 (8.27 ±0.2) 258 ±5 (10.16 ±0.2) 258 ±5 (10.16 ±0.2) 202 ±10 (7.95 ±0.39) 210 ±10 (8.27 ±0.39) 258 ±30 (10.16 ±1.18) 258 ±30 (10.16 ±1.18) 258 ±30 (10.16 ±1.18) 258 ±30 (10.16 ±1.18) 258 ±30 (10.16 ±1.18) 313 ±5 (12.32 ±0.2) 313 ±5 (12.32 ±0.2) 313 ±5 (12.32 ±0.2) d mm (inch) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) 8 x 13 (0.31 x 0.51) 10 x 18 (0.39 x 0.71) 10 x 18 (0.39 x 0.71) 10 x 18 (0.39 x 0.71) 12 x 20 (0.47 x 0.79) 12 x 20 (0.47 x 0.79) 8 x 13 (0.31 x 0.51) 10 x 18 (0.39 x 0.71) 12 x 20 (0.47 x 0.79) 12 x 20 (0.47 x 0.79) 12 x 20 (0.47 x 0.79) 12 x 20 (0.47 x 0.79) 12 x 20 (0.47 x 0.79) 12 x 20 (0.47 x 0.79) 12 x 20 (0.47 x 0.79) 12 x 20 (0.47 x 0.79) CA04020001Z-EN-INT Weight kg 5.9 5.9 7.3 10.2 10.2 12.3 14.9 20.6 20.6 20.6 24.3 23.8 14.9 20.6 31 45 45 45 45 48.7 61.7 81.7 www.eaton.eu 72 PowerXL™ variable frequency drives Sine filter Sine filter Sine filter DX-SIN3-004 - DX-SIN3-180 ⌀ d2 c a1 a DX-SIN3-004 DX-SIN3-010 DX-SIN3-016 DX-SIN3-023 DX-SIN3-032 DX-SIN3-037 DX-SIN3-048 DX-SIN3-061 DX-SIN3-072 DX-SIN3-090 DX-SIN3-115 DX-SIN3-150 DX-SIN3-180 a mm (inch) 155 (6.1) 155 (6.1) 190 (7.48) 240 (9.45) 240 (9.45) 240 (9.45) 240 (9.45) 300 (11.81) 300 (11.81) 300 (11.81) 360 (14.17) 360 (14.17) 360 (14.17) CA04020001Z-EN-INT b1 ⌀ d1 b a1 mm (inch) 130 (5.12) 130 (5.12) 170 (6.69) 190 (7.48) 190 (7.48) 190 (7.48) 190 (7.48) 240 (9.45) 240 (9.45) 240 (9.45) 264 (10.39) 264 (10.39) 264 (10.39) www.eaton.eu b mm (inch) 105 (4.13) 120 (4.72) 160 (6.3) 190 (7.48) 200 (7.87) 210 (8.27) 220 (8.66) 228 (8.97) 240 (9.45) 270 (10.63) 210 (8.27) 225 (8.86) 240 (9.45) b1 mm (inch) 56 (2.2) 71 (2.8) 67 (2.64) 105 (4.13) 105 (4.13) 115 (4.53) 125 (4.92) 133 (5.24) 145 (5.71) 171 (6.73) 125 (4.92) 140 (5.51) 154 (6.06) c mm (inch) 160 (6.3) 160 (6.3) 185 (7.28) 280 (11.02) 280 (11.02) 280 (11.02) 280 (11.02) 315 (12.4) 315 (12.4) 320 (12.6) 415 (16.34) 415 (16.34) 415 (16.34) d1 d2 4 x M5 4 x M5 4 x M5 4 x M6 4 x M6 4 x M6 4 x M6 4 x M8 4 x M8 4 x M8 4 x M8 4 x M10 4 x M10 M4 M4 M4 M6 M6 M6 M6 M8 M8 M8 M8 M8 M8 Weight kg 4.2 6.1 9.4 14.5 19.7 21.3 26.2 35 39 53.3 66 69 88.7 PowerXL™ variable frequency drives 73 Sine filter Sine filter Sine filter ≦ 450 mm (≦ 17.7") ± 3 mm (0.1") DC1, DA1 DX-SIN3-250 ≦ 320 mm (≦ 12.6") ≦ 400 mm (≦ 15.7") ≦ 450 mm (≦ 17.7") ≦ 500 mm (≦ 19.7") ⌀ 4 x M10 PE = M12 ⌀ 6 x M10 PE = M12 32.5 mm (1.3") 180 mm (7.1") 185 mm (7.3") 610 mm (24") 450 mm (17.7") ± 3 mm (0.1") DX-SIN3-440 180 mm (7.1") 480 mm (18.9") 540 mm (21.3") DX-SIN3-480 408 mm (16.1") ± 3 mm (0.1") 425 mm (16.7") ± 3 mm (0.1") PE = M12 110 mm (4.3") 125 mm (4.9") 165 mm (6.5") 160 mm (6.3") ≦ 730 mm (≦ 28.7") d1 13 x 26 mm (0.5 x 1") 8 x M10 ≦ 370 mm (≦ 14.6") CA04020001Z-EN-INT www.eaton.eu 74 PowerXL™ variable frequency drives Braking resistances DX-BR... Braking resistances DX-BR... 41 mm (1.61") DX-BR3-100 9 mm (0.35") 188 mm (7.4") 70 mm (2.76") 80 mm (3.15") DX-BR5-033 ⌀ 5.3 mm (⌀ 0.21") 10 mm (0.39") 310 mm (12.2") 330 mm (12.99") DX-BR… with connection cable a a1 b1 b c 1m (3.28 ft) 6 x 12 DX-BR200-0K4 DX-BR400-0K4 DX-BR150-0K5 DX-BR100-0K8 DX-BR200-0K8 DX-BR075-1K4 DX-BR100-1K4 DX-BR150-1K4 DX-BR100-1K6 a mm (inch) 95 (3.07) a1 mm (inch) 70 (2.76) b mm (inch) 445 (17.52) b1 mm (inch) 425 (16.73) c mm (inch) 95 (3.07) Weight kg (lbs) 2.4 (5.29) 140 (5.51) 140 (5.51) 120 (4.72) 120 (4.72) 395 (15.55) 445 (17.52) 375 (14.76) 425 (16.73) 120 (4.72) 120 (4.72) 3.7 (8.16) 4 (8.82) 230 (9.06) 210 (8.27) 445 (17.52) 425 (16.73) 120 (4.72) 5.7 (12.57) 2 x 140 (5.51) 2 x120 (4.72) 445 (17.52) 425 (16.73) 120 (4.72) 2 x 4 (8.82) CA04020001Z-EN-INT www.eaton.eu PowerXL™ variable frequency drives 75 Braking resistances DX-BR... b1 b DC1, DA1 DX-BR… with connection cable a1 a 6 x 12 c a a1 b b1 c Weight mm (inch) mm (inch) mm (inch) mm (inch) mm (inch) kg (lbs) DX-BR050-0K4 DX-BR100-0K4 DX-BR100-0K2 95 (3.07) 70 (2.76) 445 (17.52) 425 (16.73) 95 (3.07) 2.1 (4.63) 95 (3.07) 70 (2.76) 345 (13.58) 325 (12.8) 95 (3.07) 1.7 (3.75) DX-BR050-0K8 140 (5.51) 120 (4.72) 445 (17.52) 425 (16.73) 120 (4.72) 4 (8.82) DX-BR035-1K1 230 (9.06) 210 (8.27) 445 (17.52) 425 (16.73) 120 (4.72) 5.5 (12.13) DX-BR… with connection cable b1 b ⌀ c a1 a DX-BR022-1K4 DX-BR012-3K1 DX-BR022-3K1 DX-BR040-3K1 DX-BR047-3K1 DX-BR050-3K1 DX-BR006-5K1 DX-BR012-5K1 DX-BR022-5K1 DX-BR040-5K1 DX-BR047-5K1 DX-BR050-5K1 DX-BR075-5K1 DX-BR100-6K2 DX-BR006-9K2 DX-BR012-9K2 DX-BR022-9K2 DX-BR047-9K2 a mm (inch) 226 (8.9) 326 (12.83) a1 mm (inch) 200 (7.87) 300 (11.81) b mm (inch) 485 (19.09) 485 (19.09) b1 mm (inch) 380 (14.96) 380 (14.96) c mm (inch) 301 (11.85) 301 (11.85) Ø1 mm (inch) 9 (0.35) 9 (0.35) Weight kg (lbs) 8.6 (18.96) 12 (26.46) 426 (16.77) 400 (15.75) 485 (19.09) 380 (14.96) 301 (11.85) 9 (0.35) 15.5 (34.17) 526 (20.71) 626 (24.65) 500 (19.69) 600 (23.62) 485 (19.09) 485 (19.09) 380 (14.96) 380 (14.96) 301 (11.85) 301 (11.85) 9 (0.35) 9 (0.35) 18 (39.68) 20.5 (45.19) CA04020001Z-EN-INT www.eaton.eu 76 PowerXL™ variable frequency drives Braking resistances DX-BR... 380 mm (14.96") 485 mm (19.09") DX-BR002-54K3, DX-BR006-18K1, DX-BR012-18K1 600 mm (23.62") 626 mm (24.65") ⌀ 9 mm (⌀ 0.35") 40 kg (88.18 lbs) 601 mm (23.66") 380 mm (14.96") 485 mm (19.09") DX-BR002-102K4, DX-BR006-33K3 700 mm (27.56") 736 mm (28.98") CA04020001Z-EN-INT www.eaton.eu ⌀ 9 mm (⌀ 0.35") 85 kg (185.19 lbs) 1020 mm (40.16") PowerXL™ variable frequency drives 77 Notes DC1, DA1 Notes CA04020001Z-EN-INT www.eaton.eu 9000X SVX, SPX variable frequency drive 9000X variable frequency drives are ideal for sophisticated applications. With two different device series, they make a compelling case in a variety of scenarios: SVX standard variable frequency drives when it comes to simple and complex motor control systems in industrial machine building environments, and SPX application frequency drives when it comes to sophisticated, high-performance requirements. In both openloop and closed-loop modes, their vector control guarantees reliable, dynamic, and sophisticated motor control performance when working with three-phase induction or permanent magnet motors. SVX variable frequency drive Variable frequency drives for operation with two overload options: 150% or 110%. The compact enclosures are rated IP21 (NEMA 1) and IP54 (NEMA 12) and come with an integrated radio interference suppression filter. A braking chopper is integrated into all units up to size FR6, and, in addition, there are two different models. SVX…-4A…: UIN 3~400 V/UOUT 3~400 V, allocated motor outputs 0.75 – 132 kW SVX…-5A…: UIN 3~690 V/UOUT 3~690 V, allocated motor outputs 2.2 – 160 kW SPX variable frequency drive Variable frequency drives for operation with two overload options: 150% or 110%. The enclosures for the compact devices are rated IP21 (NEMA 1) and IP54 (NEMA 12) and come with an integrated radio interference suppression filter. A braking chopper is integrated into all units up to size FR6, and, in addition, there are two different models. SPX…-4A…: UIN 3~400 V/UOUT 3~400 V, allocated motor outputs 0.75 – 132 kW1) SPX…-5A…: UIN 3~690 V/UOUT 3~690 V, allocated motor outputs 2.2 – 160 kW1) 1) Higher outputs of up to 1,100 kW (400 V) and 2,000 kW (690 V) are covered by variable frequency drives with sizes FR10 to FR14. These devices are available upon request from your sales office. Variable frequency drive 9000X 79 Description variable frequency drives SVX, SPX 80 Technical overview variable frequency drives SVX, SPX 81 Key to type references 82 Ordering variable frequency drives SVX 83 variable frequency drives SPX 88 Accessories 92 Technical data variable frequency drives SVX, SPX 94 Dimensions variable frequency drives SVX, SPX CA04020001Z-EN-INT 102 www.eaton.eu SVX, SPX variable frequency drives SVX, SPX 80 Variable frequency drive 9000X SVX, SPX Description SVX, SPX Brake Resistor Power Module Brake Chopper IGBT Inverter Rectifier AC Choke Utility 3~ L1 Input L2 L3 EMC Current Sensors Motor U Output V W EMC 3~ Charg Res Fan Power Supply Measurements PE Gate Drivers Voltage Sensors Control Keypad RS232 Motor Control ASIC Motor and App lication Control Control Module Control I/O Control I/O Control I/O Control I/O Control I/O SVX variable frequency drive SPX variable frequency drive SVX units are heavy-duty, all-purpose standard variable frequency drives. Featuring a variety of application settings, they can be configured to meet virtually any challenge that arises when used to control induction motors, including applications involving multiple motors or multiple pumps run in parallel. SVX variable frequency drives are suitable for all standard applications in machines, buildings, and industrial projects. One of the factors contributing to this is their sturdy design, which features integrated chokes and EMC filters and provides effective protection against interference from the grid. In addition, their sophisticated motor control design and effective protection features for both motor and variable frequency drive guarantee reliable operation. SPX variable frequency drives are the perfect choice when it comes to demanding applications in which reliability, a highly dynamic response, precision, and power are a must. Popular applications include lifting equipment and conveyances (cranes, winches, elevators, lifts), compressors and oil pumps, chippers, crushers, mixers, extruders, take-up and pay-off units, and tunnel boring machines. Multi-purpose SPX variable frequency drives are designed to cover a wide variety of applications while keeping things simple. In fact, with their excellent flexibility, they make it easy to adapt to additional process requirements for custom and complex applications used to control induction and permanent magnet motors. On top of this, their sturdy design, which features integrated chokes and EMC filters, provides effective protection against interference from the grid. Finally, their sophisticated motor control design and effective protection features for both motor and variable frequency drive guarantee reliable operation. Essential features Essential features • Performance range: – 0.75 - 132 kW (UIN: 3~ 400 V / UOUT: 3~ 400 V) – 2.2 - 160 kW (UIN: 3~ 690 V / UOUT: 3~ 690 V) • High load capacity: – H = 2x rated operational current (2 seconds/20 seconds) and 150% overload (60 seconds/600 seconds) – L = 2x rated operational current (2 seconds/20 seconds) and 110% overload (60 seconds/600 seconds) • Ambient air temperature: -10 °C up to +50 °C without derating • Degree of protection with compact design: IP21 (NEMA1) and IP54 (NEMA12) • I/O expansion with plug-in modules (5 slots) • Optional fieldbus connection (CANopen, PROFIBUS-DP, DeviceNet), LonWorks • PID control and power factor correction (PFC) for 1 to 5 pumps • Programmable start and application wizard for an easy parameter configuration process • Multiple display (multi-monitoring) for monitoring up to 3 different readings at the same time • V/Hz control with boost and slip compensation • Dynamic open-loop and closed-loop vector control • Internal braking chopper available in sizes of up to FR9 (compact design) • Performance range: – 0.75 - 132 kW (UIN: 3~ 400 V / UOUT: 3~ 400 V) – 2.2 - 160 kW (UIN: 3~ 690 V / UOUT: 3~ 690 V) • Expanded performance range with distributed design (IP00). Please enquire: – up to 1100 kW (UIN: 3~ 400 V / UOUT: 3~ 400 V) – up to 2000 kW (UIN: 3~ 690 V / UOUT: 3~ 690 V) • High load capacity: – H = 2x rated operational current (2 seconds/20 seconds) and 150% overload (60 seconds/600 seconds) – L = 2x rated operational current (2 seconds/20 seconds) and 110% overload (60 seconds/600 seconds) • Ambient air temperature: -10 °C up to +50 °C without derating • Degree of protection with compact design: Up to 132/160 kW: IP21 (NEMA1) and IP54 (NEMA12) • I/O expansion with plug-in modules (5 slots) • Optional fieldbus connection (CANopen, PROFIBUS-DP, DeviceNet), LonWorks • PID control and power factor correction (PFC) • Direct and parallel circuit solutions, even for PM motors with high outputs • Programmable start and application wizard for an easy parameter configuration process • Multiple display (multi-monitoring) for monitoring up to 3 different readings at the same time • V/Hz control with boost and slip compensation • Dynamic open-loop and closed-loop vector control • Internal braking chopper available in sizes up to FR9 SVX, SPX CA04020001Z-EN-INT www.eaton.eu Variable frequency drive 9000X 81 SVX, SPX Technical overview SVX SPX 400 V AC, 3-phase ✓ ✓ 690 V AC, 3-phase ✓ ✓ 380 (-15%) - 500 (+10%) ✓ ✓ 525 (-15%) - 690 (±10%) ✓ ✓ Rated operational voltage Ue Mains voltage (50/60Hz) ULN Supply frequency V fLN Hz 50/60 50/60 At 110% overload Ie A 3.3 - 300 3.3 - 300 (2250)2) At 150% overload Ie A 2.2 - 245 2.2 - 245 (1940)2) With 400 V, 50 Hz (110% overload) P kW 1.1 - 160 1.1 - 160 (1200)2) With 400 V, 50 Hz (150% overload) P kW 0.75 - 132 0.75 - 132 (1100)2) With 690 V, 60 Hz (110% overload) P kW 3 - 200 3 - 200 (2000)2) With 690 V, 60 Hz (150% overload) P kW 2.2 - 160 2.2 - 160 (1800)2) SVX, SPX Rated operational current1) Assigned motor rating 1) Ambient temperature Operation ϑ °C -10 - +40 -10 - +40 Storage ϑ °C -40 - +70 -40 - +70 Operation Mode U/f control - ✓ sensorless vector control (SLV) ✓ ✓ Vector control with feedback (CLV) ✓ ✓ 1 - 16 1 - 16 400 V AC, 3-phase ✓ ✓ 690 V AC, 3-phase ✓ ✓ 0 - 320 Hz 0 - 320 Hz IP00 - (✓)2) IP21 ✓ ✓ IP54 ✓ ✓ Radio interference suppression filter ✓ ✓ Brake chopper ✓ ✓ Analog inputs parameterizable, 2 x (0 - 10 V, 0/4 - 20 mA) parameterizable, 2 x (0 - 10 V, 0/4 - 20 mA) Analog outputs parameterizable, 1 x (0/4 - 20 mA) parameterizable, 1 x (0/4 - 20 mA) Digital inputs parameterizable, 6 x (max. 30 V DC) parameterizable, 6 x (max. 30 V DC) Digital outputs parameterizable, 1 x (48 V DC / 50mA) parameterizable, 1 x (48 V DC / 50mA) Relay outputs Parameterizable, two N/Os, 8 A (24 VDC) / 8 A (250 VAC) / 0.4 A (125 VDC) RoHS, ISO 9001 Parameterizable, two N/Os, 8 A (24 VDC) / 8 A (250 VAC) / 0.4 A (125 VDC) RoHS, ISO 9001 EMC: EN 61800-3:2004+A1-2012 EMC: EN 61800-3:2004+A1-2012 Safety: EN 61800-5-1: 2003 ✓ EMC: EN 61800-3:2004+A1-2012 Safety: EN 61800-5-1: 2003 ✓ Safety: EN 61800-5-1: 2003 ✓ ✓ CE, cUL, c-Tick CE, cUL, c-Tick Switching frequency fPWM Output voltage with Ve U2 Output Frequency f2 kHz Hz Protection type Fitted with Production quality Standards Certifications Notes 1) 2) L = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. Higher outputs are covered by variable frequency drives with sizes FR10 to FR14. These devices are available as modules with protection class IP 00 upon request from your sales office. CA04020001Z-EN-INT www.eaton.eu 82 Variable frequency drive 9000X SVX, SPX Key to type references SVX, SPX SVX 007 A 1 - 4 A 1 B 1 Device series Type SVX = Standard frequency drive SPX = Performance frequency drive 1 = Standard basic device Assigned motor rating according to mains voltage category 4, 5 F07 = 0.75 HP = 0.55 kW 001 = 1 HP = 0.75 kW ... 007 = 7.5 HP = 5.5 kW ... H20 = 2000 HP = 1800 kW AFD software series Radio interference suppression filters 1 = C2 class in 1st and 2nd environments 2 = no internal RFI filter 4 = C3 class in 2nd environment Display A = Standard version A = alpha numeric Degree of protection Mains voltage category 0 = IP00/open chassis 1 = IP21/NEMA 1 2 = IP54/NEMA 12 4 = 380 (-15 %) - 500 (+10 %) 5 = 525 (-15 %) - 690 (+10 %) UL/CSA Information relevant for export to North America Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Specially designed for North America Suitable for Max. Voltage Rating SVX/SPX…-4… SVX/SPX…-5… Degree of Protection SPX…A0… SVX/SPX…A1… SVX/SPX…A2… CA04020001Z-EN-INT Brake Chopper N = no internal brake chopper B = internal brake chopper UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking E134360 NMMS, NMMS2, NMMS7. NMMS8 UL report applies to both US and Canada 3211-06 UL listed, certified by UL for use in Canada No Branch circuits 3~ 480 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) 3~ 690 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) IEC: IP00 IEC: IP21 IEC: IP54 www.eaton.eu Variable frequency drive 9000X 83 SVX, for three-phase motors 400 V AC Ordering SVX, for three-phase motors 400 V AC Protection type Part no. Article no. FR4 IP21 SVX001A1-4A1B1 125676 SVX001A2-4A1B1 125677 L = 110 % H = 150 % Ie Ie P P Ie Ie A A kW kW A A Brake chopper Frame size Assigned motor rating 1), 2) L = 110 % H = 150 % Radio interference suppression filter Rated motor current1), 2) Fitted with Rated operational current1) L = 110 % H = 150 % 1.9 ✓ ✓ ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 Price see price list Std. pack Mains voltage (50/60Hz) ULN: 380 (-15%) - 500 (+10%) V 3.3 2.2 1.1 0.75 2.6 4.3 5.6 7.6 9 12 16 23 31 38 46 61 72 Notes 3.3 4.3 5.6 7.6 9 12 16 23 31 38 46 61 1) L 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 3.6 5 6.6 8.5 11.3 15.2 21.7 29.3 36 41 55 68 2.6 3.6 5 6.6 8.5 11.3 15.2 21.7 29.3 36 41 55 FR5 FR6 FR7 IP21 IP21 IP21 1 off SVXF15A1-4A1B1 125707 SVXF15A2-4A1B1 125708 SVX002A1-4A1B1 125748 SVX002A2-4A1B1 125678 SVX003A1-4A1B1 125679 SVX003A2-4A1B1 125680 SVX005A1-4A1B1 125749 SVX005A2-4A1B1 125753 SVX006A1-4A1B1 125682 SVX006A2-4A1B1 125683 SVX007A1-4A1B1 125684 SVX007A2-4A1B1 125685 SVX010A1-4A1B1 125686 SVX010A2-4A1B1 125687 SVX015A1-4A1B1 125688 SVX015A2-4A1B1 125689 SVX020A1-4A1B1 125690 SVX020A2-4A1B1 125754 SVX025A1-4A1B1 125691 SVX025A2-4A1B1 125692 SVX030A1-4A1B1 125693 SVX030A2-4A1B1 125694 SVX040A1-4A1N1 125695 SVX040A2-4A1N1 125696 SVX040A1-4A1B1 132656 SVX040A2-4A1B1 138452 = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → Page 82 CA04020001Z-EN-INT www.eaton.eu SVX, SPX Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase 84 Variable frequency drive 9000X SVX, for three-phase motors 400 V AC Protection type Part no. Article no. FR7 IP21 SVX050A1-4A1B1 138430 SVX050A2-4A1N1 125697 SVX050A1-4A1N1 125750 SVX050A2-4A1B1 138453 L = 110 % H = 150 % Ie Ie P P Ie Ie A A kW kW A A Brake chopper Frame size Assigned motor rating 1), 2) L = 110 % H = 150 % Radio interference suppression filter Rated motor current1), 2) Fitted with Rated operational current1) L = 110 % H = 150 % Mains voltage (50/60Hz) ULN: 380 (-15%) - 500 (+10%) V 87 72 45 37 81 68 ✓ ✓ ✓ - IP54 ✓ - IP21 ✓ ✓ IP54 ✓ - IP54 ✓ ✓ IP54 ✓ ✓ IP21 ✓ - IP21 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - ✓ - IP54 ✓ ✓ IP54 ✓ ✓ IP21 ✓ - IP21 ✓ - IP54 ✓ ✓ IP54 ✓ ✓ IP21 Price see price list Std. pack Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase 105 140 170 205 261 300 Notes 87 105 140 170 205 245 55 75 90 110 132 160 45 55 75 90 110 132 1) L 99 134 161 196 231 279 81 99 134 161 196 231 FR8 FR9 IP21 IP21 1 off SVX060A2-4A1N1 125698 SVX060A2-4A1B1 138454 SVX060A1-4A1B1 138431 SVX060A1-4A1N1 125751 SVX075A1-4A1N1 125699 SVX075A2-4A1N1 125700 SVX075A1-4A1B1 132657 SVX075A2-4A1B1 138455 SVX100A1-4A1N1 125701 SVX100A2-4A1N1 125755 SVX100A1-4A1B1 132658 SVX100A2-4A1B1 138456 SVX125A1-4A1N1 125702 SVX125A2-4A1N1 125703 SVX125A1-4A1B1 135242 SVX125A2-4A1B1 138457 SVX150A1-4A1N1 125704 SVX150A2-4A1N1 125705 SVX150A2-4A1B1 138458 SVX150A1-4A1B1 138432 SVX200A1-4A1N1 125752 SVX200A2-4A1N1 125706 SVX200A2-4A1B1 138459 SVX200A1-4A1B1 132900 = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → Page 82 CA04020001Z-EN-INT www.eaton.eu Variable frequency drive 9000X 85 SVX, for three-phase motors 690 V AC SVX, for three-phase motors 690 V AC Protection type Part no. Article no. FR6 IP21 SVX002A1-5A4N1 125756 SVX002A2-5A4N1 125774 SVX002A2-5A4B1 138498 SVX002A1-5A4B1 138480 L = 110 % H = 150 % Ie Ie P P Ie Ie A A kW kW A A Brake chopper Frame size Assigned motor rating 1), 2) L = 110 % H = 150 % Radio interference suppression filter Rated motor current1), 2) Fitted with Rated operational current1) H = 150 % L = 110 % 2.9 ✓ - ✓ - IP54 ✓ ✓ IP54 ✓ ✓ IP21 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 Price see price list Std. pack Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase 5.5 7.5 10 13.5 18 22 Notes 4.5 5.5 7.5 10 13.5 18 4 5.5 7.5 11 15 18.5 3 4 5.5 7.5 11 15 4.9 6.5 8.8 12.6 17 20.9 3.8 4.9 6.5 8.8 12.6 17 1 off SVX, SPX Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V 4.5 3.2 3 2.2 3.8 SVX003A1-5A4N1 125757 SVX003A2-5A4N1 125775 SVX003A1-5A4B1 138481 SVX003A2-5A4B1 138499 SVX004A1-5A4N1 125758 SVX004A2-5A4N1 125776 SVX004A1-5A4B1 138482 SVX004A2-5A4B1 138500 SVX005A1-5A4N1 125759 SVX005A2-5A4N1 125777 SVX005A1-5A4B1 138483 SVX005A2-5A4B1 138501 SVX007A1-5A4N1 125760 SVX007A2-5A4N1 125778 SVX007A1-5A4B1 138484 SVX007A2-5A4B1 138502 SVX010A1-5A4N1 125761 SVX010A2-5A4N1 125779 SVX010A1-5A4B1 138485 SVX010A2-5A4B1 138503 SVX015A1-5A4N1 125762 SVX015A2-5A4N1 125780 SVX015A1-5A4B1 138486 SVX015A2-5A4B1 138504 1) L = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → Page 82 2) Assigned CA04020001Z-EN-INT www.eaton.eu 86 Variable frequency drive 9000X SVX, for three-phase motors 690 V AC Protection type Part no. Article no. FR6 IP21 SVX020A1-5A4N1 125763 SVX020A2-5A4N1 125781 SVX020A1-5A4B1 138487 SVX020A2-5A4B1 138505 L = 110 % H = 150 % Ie Ie P P Ie Ie A A kW kW A A Brake chopper Frame size Assigned motor rating 1), 2) L = 110 % H = 150 % Radio interference suppression filter Rated motor current1), 2) Fitted with Rated operational current1) L = 110 % H = 150 % 20.9 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP54 ✓ - IP21 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - ✓ - IP54 ✓ ✓ IP54 ✓ ✓ IP21 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 Price see price list Std. pack Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V 27 22 22 18.5 23.8 34 41 52 62 80 100 Notes 27 34 41 52 62 80 30 37 45 55 75 90 22 30 37 45 55 75 1) L 32 39 47 58 78 93 23.8 32 39 47 58 78 FR7 FR8 IP21 IP21 1 off SVX025A1-5A4N1 125764 SVX025A2-5A4N1 125782 SVX025A1-5A4B1 138488 SVX025A2-5A4B1 138506 SVX030A1-5A4N1 125765 SVX030A2-5A4N1 125783 SVX030A1-5A4B1 138489 SVX030A2-5A4B1 138507 SVX040A2-5A4N1 125784 SVX040A1-5A4N1 125766 SVX040A1-5A4B1 138490 SVX040A2-5A4B1 138508 SVX050A1-5A4N1 125767 SVX050A2-5A4N1 125785 SVX050A2-5A4B1 138509 SVX050A1-5A4B1 138491 SVX060A1-5A4N1 125768 SVX060A2-5A4N1 125786 SVX060A1-5A4B1 138492 SVX060A2-5A4B1 138510 SVX075A1-5A4N1 125769 SVX075A2-5A4N1 125787 SVX075A1-5A4B1 138493 SVX075A2-5A4B1 138511 = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → Page 82 CA04020001Z-EN-INT www.eaton.eu Variable frequency drive 9000X 87 SVX, for three-phase motors 690 V AC Protection type Part no. Article no. FR9 IP21 SVX100A1-5A4N1 125770 SVX100A2-5A4N1 125788 SVX100A1-5A4B1 138494 SVX100A2-5A4B1 138512 L = 110 % H = 150 % Ie Ie P P Ie Ie A A kW kW A A Brake chopper Frame size Assigned motor rating 1), 2) L = 110 % H = 150 % Radio interference suppression filter Rated motor current1), 2) Fitted with Rated operational current1) L = 110 % H = 150 % 93 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP54 ✓ ✓ IP21 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 Price see price list Std. pack Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase 144 170 208 Notes 125 144 170 132 160 200 110 132 160 134 162 202 114 134 162 1 off SVX, SPX Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V 125 100 110 90 114 SVX125A1-5A4N1 125771 SVX125A2-5A4N1 125789 SVX125A2-5A4B1 138513 SVX125A1-5A4B1 138495 SVX150A1-5A4N1 125772 SVX150A2-5A4N1 125790 SVX150A1-5A4B1 138496 SVX150A2-5A4B1 138514 SVX175A1-5A4N1 125773 SVX175A2-5A4N1 125791 SVX175A1-5A4B1 138497 SVX175A2-5A4B1 138515 1) L = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → Page 82 2) Assigned CA04020001Z-EN-INT www.eaton.eu 88 Variable frequency drive 9000X SPX, for three-phase motors 400 V AC SPX, for three-phase motors 400 V AC Protection type Part no. Article no. FR4 IP21 SPX001A1-4A1B1 125203 SPX001A2-4A1B1 125207 L = 110 % H = 150 % Ie Ie P P Ie Ie A A kW kW A A Brake chopper Frame size Assigned motor rating 1), 2) L = 110 % H = 150 % Radio interference suppression filter Rated motor current1), 2) Fitted with Rated operational current1) H = 150 % L = 110 % 1.9 ✓ ✓ ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 Price see price list Std. pack Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase Mains voltage (50/60Hz) ULN: 380 (-15%) - 500 (+10%) V 3.3 2.2 1.1 0.75 2.6 4.3 5.6 7.6 9 12 16 23 31 38 46 61 72 Notes 3.3 4.3 5.6 7.6 9 12 16 23 31 38 46 61 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 1) L 3.6 5 6.6 8.5 11.3 15.2 21.7 29.3 36 41 55 68 2.6 3.6 5 6.6 8.5 11.3 15.2 21.7 29.3 36 41 55 FR5 FR6 FR7 IP21 IP21 IP21 1 off SPXF15A1-4A1B1 125675 SPXF15A2-4A1B1 125480 SPX002A1-4A1B1 125657 SPX002A2-4A1B1 125216 SPX003A1-4A1B1 125658 SPX003A2-4A1B1 125226 SPX005A1-4A1B1 125659 SPX005A2-4A1B1 125245 SPX006A1-4A1B1 125249 SPX006A2-4A1B1 125251 SPX007A1-4A1B1 125660 SPX007A2-4A1B1 125260 SPX010A1-4A1B1 125661 SPX010A2-4A1B1 125662 SPX015A1-4A1B1 125663 SPX015A2-4A1B1 125664 SPX020A1-4A1B1 125665 SPX020A2-4A1B1 125291 SPX025A1-4A1B1 125666 SPX025A2-4A1B1 125302 SPX030A1-4A1B1 125667 SPX030A2-4A1B1 125313 SPX040A1-4A1N1 125319 SPX040A2-4A1N1 125325 SPX040A1-4A1B1 134844 SPX040A2-4A1B1 138609 = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → Page 82 CA04020001Z-EN-INT www.eaton.eu Variable frequency drive 9000X 89 SPX, for three-phase motors 400 V AC Protection type Part no. Article no. FR7 IP21 SPX050A1-4A1N1 125331 SPX050A2-4A1N1 125337 SPX050A1-4A1B1 138606 SPX050A2-4A1B1 138610 L = 110 % H = 150 % Ie Ie P P Ie Ie A A kW kW A A Brake chopper Frame size Assigned motor rating 1), 2) L = 110 % H = 150 % Radio interference suppression filter Rated motor current1), 2) Fitted with Rated operational current1) L = 110 % H = 150 % Mains voltage (50/60Hz) ULN: 380 (-15%) - 500 (+10%) V 87 72 45 37 81 68 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 Price see price list Std. pack Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase 105 140 170 205 261 300 Notes 87 105 140 170 205 245 55 75 90 110 132 160 45 55 75 90 110 132 99 134 161 196 231 279 81 99 134 161 196 231 FR8 FR9 IP21 IP21 SVX, SPX 1 off SPX060A1-4A1N1 125668 SPX060A2-4A1N1 125348 SPX060A1-4A1B1 138607 SPX060A2-4A1B1 138611 SPX075A1-4A1N1 125354 SPX075A2-4A1N1 125359 SPX075A1-4A1B1 138608 SPX075A2-4A1B1 138612 SPX100A1-4A1N1 125365 SPX100A2-4A1N1 125370 SPX100A1-4A1B1 131744 SPX100A2-4A1B1 138613 SPX125A1-4A1N1 125669 SPX125A2-4A1N1 125377 SPX125A1-4A1B1 134489 SPX125A2-4A1B1 138614 SPX150A1-4A1N1 125381 SPX150A2-4A1N1 125385 SPX150A1-4A1B1 129701 SPX150A2-4A1B1 138615 SPX200A1-4A1N1 125670 SPX200A2-4A1N1 125398 SPX200A1-4A1B1 134845 SPX200A2-4A1B1 138616 1) L = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → Page 82 2) Assigned CA04020001Z-EN-INT www.eaton.eu 90 Variable frequency drive 9000X SPX, for three-phase motors 690 V AC SPX, for three-phase motors 690 V AC Protection type Part no. Article no. FR6 IP21 SPX002A1-5A4N1 125212 SPX002A2-5A4N1 125218 SPX002A1-5A4B1 138638 SPX002A2-5A4B1 129582 L = 110 % H = 150 % Ie Ie P P Ie Ie A A kW kW A A Brake chopper Frame size Assigned motor rating 1), 2) L = 110 % H = 150 % Radio interference suppression filter Rated motor current1), 2) Fitted with Rated operational current1) H = 150 % L = 110 % 2.9 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP54 ✓ - IP21 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ ✓ IP54 ✓ ✓ IP21 ✓ - IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 Price see price list Std. pack Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V 4.5 3.2 3 2.2 3.8 5.5 7.5 10 13.5 18 22 Notes 4.5 4 5.5 5.5 7.5 7.5 10 11 13.5 15 18 18.5 3 4 5.5 7.5 11 15 1) L 4.9 6.5 8.8 12.6 17 20.9 3.8 4.9 6.5 8.8 12.6 17 1 off SPX003A2-5A4N1 125228 SPX003A1-5A4N1 125222 SPX003A1-5A4B1 138639 SPX003A2-5A4B1 129583 SPX004A1-5A4N1 125232 SPX004A2-5A4B1 129584 SPX004A1-5A4B1 138640 SPX004A2-5A4N1 125236 SPX005A1-5A4N1 125241 SPX005A2-5A4N1 125247 SPX005A1-5A4B1 138641 SPX005A2-5A4B1 129585 SPX007A1-5A4N1 125256 SPX007A2-5A4N1 125262 SPX007A1-5A4B1 138642 SPX007A2-5A4B1 129586 SPX010A1-5A4N1 125267 SPX010A2-5A4N1 125272 SPX010A1-5A4B1 138643 SPX010A2-5A4B1 129587 SPX015A1-5A4N1 125277 SPX015A2-5A4N1 125282 SPX015A1-5A4B1 138644 SPX015A2-5A4B1 129588 = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → Page 82 2) Assigned CA04020001Z-EN-INT www.eaton.eu Variable frequency drive 9000X 91 SPX, for three-phase motors 690 V AC Protection type Part no. Article no. FR6 IP21 SPX020A1-5A4N1 125287 SPX020A2-5A4N1 125293 SPX020A1-5A4B1 138645 SPX020A2-5A4B1 129589 L = 110 % H = 150 % Ie Ie P P Ie Ie A A kW kW A A Brake chopper Frame size Assigned motor rating 1), 2) L = 110 % H = 150 % Radio interference suppression filter Rated motor current1), 2) Fitted with Rated operational current1) L = 110 % H = 150 % 20.9 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP54 ✓ ✓ IP21 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP54 ✓ ✓ IP21 Price see price list Std. pack Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase 34 41 52 62 80 100 Notes 27 34 41 52 62 80 30 37 45 55 75 90 22 30 37 45 55 75 32 39 47 58 78 93 23.8 32 39 47 58 78 FR7 FR8 IP21 IP21 1 off SVX, SPX Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V 27 22 22 18.5 23.8 SPX025A1-5A4N1 125298 SPX025A2-5A4N1 125304 SPX025A2-5A4B1 129590 SPX025A1-5A4B1 138646 SPX030A1-5A4N1 125309 SPX030A2-5A4N1 125315 SPX030A1-5A4B1 138647 SPX030A2-5A4B1 129591 SPX040A1-5A4N1 125321 SPX040A2-5A4N1 125327 SPX040A1-5A4B1 138648 SPX040A2-5A4B1 129592 SPX050A1-5A4N1 125333 SPX050A2-5A4N1 125339 SPX050A1-5A4B1 138649 SPX050A2-5A4B1 129593 SPX060A1-5A4N1 125344 SPX060A2-5A4N1 125350 SPX060A1-5A4B1 138650 SPX060A2-5A4B1 129594 SPX075A1-5A4N1 125356 SPX075A2-5A4N1 125361 SPX075A2-5A4B1 129595 SPX075A1-5A4B1 138651 1) L = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. 2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → Page 82 CA04020001Z-EN-INT www.eaton.eu 92 Variable frequency drive 9000X SPX, for three-phase motors 690 V AC, Accessories Protection type Part no. Article no. FR9 IP21 SPX100A1-5A4N1 125367 SPX100A2-5A4N1 125372 SPX100A1-5A4B1 138652 SPX100A2-5A4B1 129596 L = 110 % H = 150 % Ie Ie P P Ie Ie A A kW kW A A Brake chopper Frame size Assigned motor rating 1), 2) L = 110 % H = 150 % Radio interference suppression filter Rated motor current1), 2) Fitted with Rated operational current1) L = 110 % H = 150 % 93 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 ✓ - IP21 ✓ - IP54 ✓ ✓ IP21 ✓ ✓ IP54 Price see price list Std. pack Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V 125 100 110 90 114 144 170 208 Notes 125 132 144 160 170 200 110 132 160 134 162 202 114 134 162 FR9 IP21 1 off SPX125A1-5A4N1 125375 SPX125A2-5A4N1 125379 SPX125A1-5A4B1 138653 SPX125A2-5A4B1 129597 SPX150A1-5A4N1 125383 SPX150A2-5A4N1 125387 SPX150A1-5A4B1 138654 SPX150A2-5A4B1 129598 1 off SPX175A1-5A4N1 125389 SPX175A2-5A4N1 125391 SPX175A1-5A4B1 138655 SPX175A2-5A4B1 129599 1) L = 110% overload for 60 s every 10 min. H = 150% overload for 60 s every 10 min. motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz) Information relevant for export to North America → Page 82 2) Assigned Accessories SPX, for three-phase motors 690 V AC, Accessories Description For use with Part no. Article no. Price see price list Std. pack Information relevant for export to North America With illuminated LCD display Plain text, multi-line With control buttons and function keys Front IP54 SVX, SPX KEYPAD-LOC/REM 139787 1 off Product Standards Mounting frame for control panel door 3 m KEYPADLOC/REM OPTRMT-KIT 126868 1 off Connection between variable frequency drive and PC 1.5 m SVX, SPX SVDRIVECABLE 129001 1 off External keypad Mounting unit UL File No. UL Category Control No. CSA File No. Connection cable CSA Class No. North America Certification Suitable for CA04020001Z-EN-INT www.eaton.eu UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking E134360 NMMS, NMMS2, NMMS7. NMMS8 UL report applies to both US and Canada 3211-06 UL listed, certified by UL for use in Canada Branch circuits Variable frequency drive 9000X 93 Accessories Accessories Description For use with Part no. Article no. Price see price list Std. pack Information relevant for export to North America Expansion modules System bus adapter SPX System bus adapter with CANopen® interface RS232 adapter SPX SPX Product Standards OPTD1 125077 OPTD2 125078 OPTD3 125079 1 off UL File No. UL Category Control No. CSA File No. Output expansion 1 relay output (NO/NC) 1 relay output (NC) 1 Thermistor input 2 relay outputs (NO/NC) SPX OPTA3 125050 SVX, SPX 1 relay output (NO) 5 digital inputs (42 - 240 V AC) 3 relay outputs (NO) SVX, SPX 1 relay output (NO/NC) 1 relay output (NO) 1 Thermistor input SVX, SPX OPTA2 125049 OPTB9 125064 OPTB5 125062 OPTB2 125060 6 digital inputs External 24 V supply 6 digital inputs 1 digital output 2 analog inputs (mA/V) 1 analog output 3 digital inputs 1 relay output (NO/NC) 1 digital output 6 digital inputs 1 digital output 2 analog inputs (mA/V) 1 analog output 1 analog input (mA, isolated) 2 analog outputs (mA, isolated) SVX, SPX HTL (+15 V/24 V) Master / Slave capability SVX, SPX 1 off CSA Class No. North America Certification Suitable for UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking E134360 NMMS, NMMS2, NMMS7. NMMS8 UL report applies to both US and Canada 3211-06 UL listed, certified by UL for use in Canada Branch circuits I/O expansion SVX, SPX OPTB1 125059 OPTA9 125055 1 off SVX, SPX OPTAA 125056 SPX OPTA8 125054 SVX, SPX OPTB4 125061 SPX OPTA7 125053 1 off SVX, SPX OPTB8 125063 1 off OPTC2 125067 OPTC3 125068 OPTC4 125069 OPTC6 125710 OPTC5 125070 OPTC7 125071 OPTC8 125072 OPTCI 125075 OPTCJ 125076 1 off Encoder module Temperature sensor expansion 3 Pt100 External 24 V supply Fieldbus modules The field bus module is plugged into the variable-frequency drive. Modbus RS485 Screw terminals PROFIBUS-DP Screw terminals LonWorks Screw terminals CANopen® Screw terminals PROFIBUS-DP SUB-D 9 pole, socket DeviceNet SUB-D 9 pole, socket Modbus RS485 SUB-D 9 pole, socket Modbus-TCP RJ45, 8-pole BACnet/IP RJ45, 8-pole SVX, SPX SVX, SPX SVX, SPX SVX, SPX SVX, SPX SVX, SPX SVX, SPX SVX, SPX SVX, SPX CA04020001Z-EN-INT www.eaton.eu SVX, SPX The expansion module is plugged into the variable-frequency drive. Adapters 94 Variable frequency drive 9000X Variable frequency drive 9000X SVX, SPX (U U2: 400 (Ue: 400 VV AC, AC, 3-phase, 3-phase/U2: 400VVAC, AC,3-phase 3-phase e: 400 95 (Ue: 400 U2: 400 SVX, SPX (Ue: 400 VV AC, AC, 3-phase, 3-phase/U2: 400VVAC, AC,3-phase) 3-phase Technical data SVX, SPX (Ue: 400 V AC, 3-phase/U2: 400 V AC, 3-phase SVX001… SPX001… SVXF15… SPXF15… SVX002… SPX002… SVX003… SPX003… SVX005… SPX005… SVX006… SPX006… SVX007… SPX007… SVX010… SPX010… SVX015… SPX015… SVX020… SPX020… CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 General Standards Certifications EMC: EN 61800-3:2004+A1-2012 Safety: EN 61800-5-1: 2003 CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick EMC: EN 61800-3:2004+A1-2012 Safety: EN 61800-5-1: 2003 CE, cUL, c-Tick CE, cUL, c-Tick Production quality RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 Climatic proofing RoHS, ISO 9001 RoHS, ISO 9001 ρw % < 95% relative humidity, no condensation, no corrosion, no dripping water < 95% relative humidity, no condensation, no corrosion, no dripping water Operation ϑ °C -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 Storage ϑ °C -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 Radio interference level Radio interference class (EMC) C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd 1st and 2nd 1st and 2nd 1st and 2nd environments environments environments environments Vertical Vertical Vertical Vertical C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. m 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 3000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 3000 m BGV A3 (VBG4, finger- and back-of-hand proof) kg 5 5 5 5 5 Environment (EMC) Mounting position Altitude Protection against direct contact Weight 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments Vertical Vertical Vertical Vertical Vertical Vertical 5 8.1 8.1 8.1 18.5 Main circuit Supply Rated operational voltage Ue V 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase Mains voltage (50/60Hz) ULN V 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz Output voltage with Ve U2 V 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase Output Frequency f2 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz Switching frequency fPWM kHz 10 (adjustable 1 - 16) 10 (adjustable 1 - 16) 10 (adjustable 1 - 16) 10 (adjustable 1 - 16) 10 (adjustable 1 - 16) 10 (adjustable 1 - 16) 10 (adjustable 1 - 16) 10 (adjustable 1 - 16) 10 (adjustable 1 - 16) 10 (adjustable 1 - 16) 0.01 0.01 0.01 0.01 Power section Function Frequency inverter with internal DC link and IGBT inverter Frequency inverter with internal DC link and IGBT inverter Operation Mode SVX… Δf Hz U/f control sensorless vector control (SLV) U/f control sensorless vector control (SLV) Vector control with feedback (CLV) 0.01 0.01 At 110% overload Ie A 3.3 4.3 5.6 7.6 9 12 16 23 31 38 At 150% overload Ie A 2.2 3.3 4.3 5.6 7.6 9 12 16 23 31 With 400 V, 50 Hz (110% overload) P kW 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 With 400 V, 50 Hz (150% overload) P kW 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 With 440 - 480 V, 60 Hz (110% overload) P HP 1.5 2 3 5 6 7.5 10 15 20 25 With 440 - 480 V, 60 Hz (150% overload) P HP 1 1.5 2 3 5 6 7.5 10 15 20 External control voltage Uc V 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) Reference voltage Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) SPX… Frequency resolution (setpoint value) 0.01 0.01 U/f control sensorless vector control (SLV) U/f control sensorless vector control (SLV) Vector control with feedback (CLV) 0.01 0.01 Rated operational current Motor feeder Assigned motor rating Note For AC motors with internal and external ventilation with 50 Hz / 60 Hz For AC motors with internal and external ventilation with 50 Hz / 60 Hz Control section CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu SVX, SPX Ambient temperature 96 Variable frequency drive 9000X Variable frequency drive 9000X SVX, SPX (U U2: 400 (Ue: 400 VV AC, AC, 3-phase, 3-phase/U2: 400VVAC, AC,3-phase) 3-phase e: 400 SVX025… SPX025… SVX030… SPX030… 97 (Ue: 400 U2: 400 SVX, SPX (Ue: 400 VV AC, AC, 3-phase, 3-phase/U2: 400VVAC, AC,3-phase) 3-phase SVX040… SPX040… SVX050… SPX050… SVX060… SPX060… SVX075… SPX075… SVX100… SPX100… SVX125… SPX125… SVX150… SPX150… SVX200… SPX200… CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 General Standards Certifications EMC: EN 61800-3:2004+A1-2012 Safety: EN 61800-5-1: 2003 CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick EMC: EN 61800-3:2004+A1-2012 Safety: EN 61800-5-1: 2003 CE, cUL, c-Tick CE, cUL, c-Tick Production quality RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 Climatic proofing RoHS, ISO 9001 RoHS, ISO 9001 ρw % < 95% relative humidity, no condensation, no corrosion, no dripping water < 95% relative humidity, no condensation, no corrosion, no dripping water Operation ϑ °C -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 Storage ϑ °C -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 Radio interference level Radio interference class (EMC) C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd 1st and 2nd 1st and 2nd 1st and 2nd environments environments environments environments Vertical Vertical Vertical Vertical C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. m 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 3000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 3000 m BGV A3 (VBG4, finger- and back-of-hand proof) kg 18.5 18.5 35 35 35 Environment (EMC) Mounting position Altitude Protection against direct contact Weight 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments Vertical Vertical Vertical Vertical Vertical Vertical 58 58 58 146 146 Main circuit Supply Rated operational voltage Ue V 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase Mains voltage (50/60Hz) ULN V 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz Output voltage with Ve U2 V 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase 400 V AC, 3-phase Output Frequency f2 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz Switching frequency fPWM kHz 10 (adjustable 1 - 16) 10 (adjustable 1 - 16) 3.6 (adjustable 1 - 10) 3.6 (adjustable 1 - 10) 3.6 (adjustable 1 - 10) 3.6 (adjustable 1 - 10) 3.6 (adjustable 1 - 10) 3.6 (adjustable 1 - 10) 3.6 (adjustable 1 - 10) 3.6 (adjustable 1 - 10) 0.01 0.01 0.01 0.01 Power section Function Frequency inverter with internal DC link and IGBT inverter Frequency inverter with internal DC link and IGBT inverter Operation Mode SVX… Δf Hz U/f control sensorless vector control (SLV) U/f control sensorless vector control (SLV) Vector control with feedback (CLV) 0.01 0.01 At 110% overload Ie A 46 61 72 87 105 140 170 205 261 300 At 150% overload Ie A 38 46 61 72 87 105 140 170 205 245 With 400 V, 50 Hz (110% overload) P kW 22 30 37 45 55 75 90 110 132 160 With 400 V, 50 Hz (150% overload) P kW 18.5 22 30 37 45 55 75 90 110 132 With 440 - 480 V, 60 Hz (110% overload) P HP 30 40 50 60 75 100 125 150 200 250 With 440 - 480 V, 60 Hz (150% overload) P HP 25 30 40 50 60 75 100 125 150 200 External control voltage Uc V 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) Reference voltage Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) SPX… Frequency resolution (setpoint value) 0.01 0.01 U/f control sensorless vector control (SLV) U/f control sensorless vector control (SLV) Vector control with feedback (CLV) 0.01 0.01 Rated operational current Motor feeder Assigned motor rating Note For AC motors with internal and external ventilation with 50 Hz / 60 Hz For AC motors with internal and external ventilation with 50 Hz / 60 Hz Control section CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu SVX, SPX Ambient temperature 98 Variable frequency drive 9000X Variable frequency drive 9000X SVX, SPX (U U2: 690V (Ue: 400 VV AC, AC, 3-phase, 3-phase/U2: 400 VAC, AC,3-phase) 3-phase e: 690 SVX002… SPX002… SVX003… SPX003… 99 SVX,SPX SPX(Ue: (Ue: 400 690 V AC, 3-phase/U2: 3-phase, U2: 690V SVX, 400 VAC, AC,3-phase) 3-phase SVX004… SPX004… SVX005… SPX005… SVX007… SPX007… SVX010… SPX010… SVX015… SPX015… SVX020… SPX020… SVX025… SPX025… SVX030… SPX030… CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 General Standards Certifications EMC: EN 61800-3:2004+A1-2012 Safety: EN 61800-5-1: 2003 CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick EMC: EN 61800-3:2004+A1-2012 Safety: EN 61800-5-1: 2003 CE, cUL, c-Tick CE, cUL, c-Tick Production quality RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 Climatic proofing RoHS, ISO 9001 RoHS, ISO 9001 ρw % < 95% relative humidity, no condensation, no corrosion, no dripping water < 95% relative humidity, no condensation, no corrosion, no dripping water Operation ϑ °C -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 Storage ϑ °C -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 Radio interference level Radio interference class (EMC) C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd 1st and 2nd 1st and 2nd 1st and 2nd environments environments environments environments Vertical Vertical Vertical Vertical C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. m 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 3000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 3000 m BGV A3 (VBG4, finger- and back-of-hand proof) kg 18.5 18.5 18.5 18.5 18.5 Environment (EMC) Mounting position Altitude Protection against direct contact Weight 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments Vertical Vertical Vertical Vertical Vertical Vertical 18.5 18.5 18.5 18.5 35 Main circuit Supply Rated operational voltage Ue V 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase Mains voltage (50/60Hz) ULN V 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz Output voltage with Ve U2 V 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase Output Frequency f2 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz Switching frequency fPWM kHz 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 0.01 0.01 0.01 0.01 Power section Function Frequency inverter with internal DC link and IGBT inverter Frequency inverter with internal DC link and IGBT inverter Operation Mode SVX… Δf Hz U/f control sensorless vector control (SLV) U/f control sensorless vector control (SLV) Vector control with feedback (CLV) 0.01 0.01 At 110% overload Ie A 4.5 5.5 7.5 10 13.5 18 22 27 34 41 At 150% overload Ie A 3.2 4.5 5.5 7.5 10 13.5 18 22 27 34 With 690 V, 60 Hz (110% overload) P kW 3 4 5.5 7.5 11 15 18.5 22 30 37 With 690 V, 60 Hz (150% overload) P kW 2.2 3 4 5.5 7.5 11 15 18.5 22 30 With 550 - 600 V, 60 Hz (110% overload) P HP 3 4 5 7.5 10 15 20 25 30 40 With 550 - 600 V, 60 Hz (150% overload) P HP 2 3 4 5 7.5 10 15 20 25 30 External control voltage Uc V 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) Reference voltage Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) SPX… Frequency resolution (setpoint value) 0.01 0.01 U/f control sensorless vector control (SLV) U/f control sensorless vector control (SLV) Vector control with feedback (CLV) 0.01 0.01 Rated operational current Motor feeder Assigned motor rating Note For AC motors with internal and external ventilation with 50 Hz / 60 Hz For AC motors with internal and external ventilation with 50 Hz / 60 Hz Control section CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu SVX, SPX Ambient temperature 100 Variable frequency drive 9000X Variable frequency drive 9000X SVX, SPX (U U2: 690V (Ue: 400 VV AC, AC, 3-phase, 3-phase/U2: 400 VAC, AC,3-phase) 3-phase e: 690 SVX040… SPX040… SVX050… SPX050… 101 SVX,SPX SPX(Ue: (Ue: 400 690 V AC, 3-phase/U2: 3-phase, U2: 690V SVX, 400 VAC, AC,3-phase) 3-phase SVX060… SPX060… SVX075… SPX075… SVX100… SPX100… SVX125… SPX125… SVX150… SPX150… SVX175… SPX175… SVX200… SPX200… CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 General Standards Certifications EMC: EN 61800-3:2004+A1-2012 Safety: EN 61800-5-1: 2003 CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick CE, cUL, c-Tick EMC: EN 61800-3:2004+A1-2012 Safety: EN 61800-5-1: 2003 CE, cUL, c-Tick CE, cUL, c-Tick Production quality RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 RoHS, ISO 9001 Climatic proofing ρw RoHS, ISO 9001 % < 95% relative humidity, no condensation, no corrosion, no dripping water RoHS, ISO 9001 < 95% relative humidity, no condensation, no corrosion, no dripping water Ambient temperature Operation ϑ °C -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 -10 - +40 Storage ϑ °C -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 -40 - +70 Radio interference class (EMC) C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd 1st and 2nd 1st and 2nd 1st and 2nd environments environments environments environments Vertical Vertical Vertical Vertical C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments m 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 3000 m BGV A3 (VBG4, finger- and back-of-hand proof) 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 3000 m BGV A3 (VBG4, finger- and back-of-hand proof) kg 35 58 58 58 146 Environment (EMC) Mounting position Altitude Protection against direct contact Weight Vertical Vertical Vertical Vertical Vertical 146 146 146 176 SVX, SPX Radio interference level Main circuit Supply Rated operational voltage Ue V 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase Mains voltage (50/60Hz) ULN V 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%) Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Frequency range fLN Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz 45 - 66 Hz Output voltage with Ve U2 V 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase 690 V AC, 3-phase Output Frequency f2 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz 0 - 320 Hz Switching frequency fPWM kHz 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 1.5 (adjustable 1 - 6) 0.01 0.01 0.01 Power section Function Frequency inverter with internal DC link and IGBT inverter Frequency inverter with internal DC link and IGBT inverter Operation Mode SVX… Δf Hz U/f control sensorless vector control (SLV) U/f control sensorless vector control (SLV) Vector control with feedback (CLV) 0.01 0.01 At 110% overload Ie A 52 62 80 100 125 144 170 208 261 At 150% overload Ie A 41 52 62 80 100 125 144 170 208 With 690 V, 60 Hz (110% overload) P kW 45 55 75 90 110 132 160 200 250 With 690 V, 60 Hz (150% overload) P kW 37 45 55 75 90 110 132 160 200 With 550 - 600 V, 60 Hz (110% overload) P HP 50 60 75 100 125 150 175 200 250 With 550 - 600 V, 60 Hz (150% overload) P HP 40 50 60 75 100 125 150 175 200 External control voltage Uc V 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) 24 V DC (max. 250 mA) Reference voltage Us V 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) 10 V DC (max. 10 mA) SPX… Frequency resolution (setpoint value) 0.01 0.01 U/f control sensorless vector control (SLV) U/f control sensorless vector control (SLV) Vector control with feedback (CLV) 0.01 0.01 Rated operational current Motor feeder Assigned motor rating Note For AC motors with internal and external ventilation with 50 Hz / 60 Hz For AC motors with internal and external ventilation with 50 Hz / 60 Hz Control section CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 102 Variable frequency drive 9000X SVX, SPX Dimensions SVX, SPX Sizes FR4 - FR6 Protection type IP20/NEMA 0 and IP20/NEMA 0 ⌀1 ⌀1 b b1 ⌀2 a1 a ⌀1 c1 c2 c a mm (inch) 128 (5) 143 (5.6) 195 (7.6) a1 mm (inch) 100 (3.9) 100 (3.9) 148 (5.8) b mm (inch) 327 (12.9) 419 (16.5) 558 (22) b1 mm (inch) 313 (12.3) 406 (16) 541 (21.3) b2 mm (inch) 292 (11.5) 389 (15.3) 519 (20.4) c mm (inch) 190 (7.5) 214 (8.4) 237 (9.3) c1 mm (inch) 77 (3) 100 (3.9) 105 (4.2) c2 mm (inch) 126 (4.9) 148 (5.9) 165 (6.5) Sizes FR7 Protection type IP20/NEMA 0 and IP20/NEMA 0 ⌀ 9 mm (⌀ 0.4") ⌀ 9 mm (⌀ 0.4") 614 mm (24.2") 630 mm (25.8") ⌀ 18 mm (⌀ 0.7") 237 mm (9.3") 190 mm (7.5") CA04020001Z-EN-INT ⌀ 9 mm (⌀ 0.4") www.eaton.eu 257 mm (10.1") 35 kg (77.2 lbs) Ø1 mm (inch) 7 (0.3) 7 (0.3) 9 (0.4) Ø2 mm (inch) 13 (0.5) 13 (0.5) 15.5 (0.6) Weight kg (lbs) 5 (11) 8 (17.9) 19 (40.8) Size FR4 FR5 FR6 Variable frequency drive 9000X 103 SVX, SPX Sizes FR8 Protection type IP20/NEMA 0 and IP20/NEMA 0 255 mm (10") ⌀ 9 mm (⌀ 0.4") ⌀ 9 mm (⌀ 0.4") 732 mm (28.8") 764 mm (30.1") SVX, SPX ⌀ 18 mm (⌀ 0.7") 291 mm (11.5") 344 mm (13.5") ⌀ 9 mm (⌀ 0.4") 58 kg (127 lbs) Sizes FR9 Protection type IP20/NEMA 0 and IP20/NEMA 0 ⌀ 9 mm (⌀ 0.4") ⌀ 9 mm (⌀ 0.4") 1120 mm (44.1") 400 mm (15.7") 480 mm (18.9") 1150 mm (45.3") ⌀ 29 mm (⌀ 0.9") ⌀ 9 mm (⌀ 0.4") 340 mm (13.4") 362 mm (14.3") 146 kg (321.9 lbs) CA04020001Z-EN-INT www.eaton.eu DS7 soft starters in xStart system – Soft to start, powerful in torque The soft starters have become increasingly established as an alternative to the star-delta starter. The DS7 replaces the mechanical contactor and extends the function “Motor soft start”. Motor run-up is soft but still at a higher torque than other available solutions using the patented method. Extended service intervals and reduced operating costs are welcomed side effects. Designed for normal applications such as pumps, fans and small conveyors, the compact DS7 is ideal. The DS7 is also available with a SmartWire-DT connection to simplify wiring and enhance functionality as an automation solution. DS7 soft starters 105 System overview DS7 soft starters < 32 A 106 DS7 soft starters > 32 A 108 Key to type references DS7 soft starters 109 Description DS7 soft starters 110 Ordering DS7 soft starters 111 Accessories DS7 112 General information on Engineering 116 Design with different load cycles 118 Setting of potentiometer 119 Connection examples 120 Assigned switching and protective elements 122 Technical data DS7 soft starters 124 Dimensions DS7 soft starters 130 Superfast semiconductor fuses, Fuse Bases 131 CA04020001Z-EN-INT www.eaton.eu DS7 Engineering 106 DS7 soft starters DS7 < 32 A System overview DS7 < 32 A 20 19 26 24 25 21 18 15 22 23 17 16 15 11 12 13 14 7 1 2 3 4 4 5 6 4 7 10 10 9 2 T1 4 T2 6 T3 9 8 CA04020001Z-EN-INT www.eaton.eu 2 T1 4 T2 6 T3 27 DS7 soft starters 107 DS7 < 32 A Soft starter DS7 with SmartWire-DT 1 → page 111 DS7 soft starters in construction size 1 for assigned motor current up to 12 A 15 Standard auxiliary contact → Industrial Switchgear 2011 catalog, chapter 7 2 Early-make auxiliary contact 16 → Industrial Switchgear 2011 catalog, chapter 7 → page 111 17 Door coupling handle 3 → page 111 DS7-FAN-32 device fan PKZM0 motor-protective circuit-breakers 4 → page 115 SmartWire-DT gateway 5 6 SmartWire-DT flat band conductor overload relay 7 8 9 10 11, 12 13 three-phase commoning link 26 → page 113 top-hat rail adapter 14 25 → Industrial Switchgear 2011 catalog, chapter 8 Busbar adapter → page 113 24 → Industrial Switchgear 2011 catalog, chapter 8 Motor-starter combination with PKE → page 113 PKZM0-XM wiring set 23 → Industrial Switchgear 2011 catalog, chapter 7 Motor-starter combination with PKZ → page 113 PKZM0-XDM wiring set in tool-less plug connection 22 → Industrial Switchgear 2011 catalog, chapter 7 Standard auxiliary contact → page 113 Base for motor plugs 21 → Industrial Switchgear 2011 catalog, chapter 7 trip indicator switch → page 113 Motor plugs in tool-less plug connection 20 → Industrial Switchgear 2011 catalog, chapter 7 Voltage release → page 182 19 → Industrial Switchgear 2011 catalog, chapter 7 Extension terminal → page 182 18 → Industrial Switchgear 2011 catalog, chapter 7 PKE motor-protective circuit-breakers → page 182 SmartWire-DT external device plug → Industrial Switchgear 2011 catalog, chapter 7 27 → page 113 → page 114 CA04020001Z-EN-INT www.eaton.eu DS7 DS7 soft starters in construction size 2 for assigned motor current up to 32 A 108 DS7 soft starters DS7 > 32 A DS7 > 32 A 11 10 16 12 15 17 18 7 13 19 23 14 22 20 21 6 5 4 1 2 7 3 10 9 8 CA04020001Z-EN-INT www.eaton.eu DS7 soft starters 109 DS7 > 32 A 1 DS7 with SmartWire-DT Standard auxiliary contact/Trip-indicating auxiliary switch → page 111 13 → Industrial Switchgear 2011 catalog, chapter 17 DS7 size 4 up to 200 A NZM communication module for SmartWire-DT 2 → page 111 14 → Industrial Switchgear 2011 catalog, chapter 17 3 DS7 size 3 up to 100 A data management interface (DMI module) → page 111 15 → Industrial Switchgear 2011 catalog, chapter 17 Device fan Voltage release/Early-make auxiliary contact 4 → page 115 16 → Industrial Switchgear 2011 catalog, chapter 17 Superfast semiconductor fuses Terminal cover for terminals 5 → page 112 17 → page 114 Fuse bases for superfast semiconductor fuses 6 IP2X protection against contact with a finger → page 113 18 → page 115 IP2X protection against contact with a finger Terminal cover for cable lugs 7 → page 115 19 → page 114 connection width extension 8 9 Gateways for SmartWire-DT 20 → Industrial Switchgear 2011 catalog, chapter 17 21 Control circuit terminal → page 182 → Industrial Switchgear 2011 catalog, chapter 17 SmartWire-DT external device plug Box terminals 10 → page 182 22 → Industrial Switchgear 2011 catalog, chapter 17 11 NZM circuit-breaker Tunnel terminals for Al and Cu cable → Industrial Switchgear 2011 catalog, chapter 17 23 → Industrial Switchgear 2011 catalog, chapter 17 12 spacer → Industrial Switchgear 2011 catalog, chapter 17 Key to type references DS7 > 32 A DS7 - 3 4 0 SX 004 N 0 -N Device series Options Generation 7 N = No option D = SmartWire-DT L = Expanded temperature range down to -40 °C Number of phases 3 = Three-phase mains supply voltage Protection type 0 = IP20 Voltage class 4 = 400 V (380 V - 15 % to 480 V + 10 %) Radio interference suppression filters N = No internal radio interference suppression filter Control voltage supply 0 = 24 V AC/DC 2 = 110/230 V AC D = 24 V DC SmartWire-DT Rated operational current 004 = 4 A : 200 = 200 A Device version SX = Standard soft starters with internal bypass CA04020001Z-EN-INT www.eaton.eu DS7 overload relay → Industrial Switchgear 2011 catalog, chapter 6 110 DS7 soft starters System Description System Application Features The DS7 series soft starters are twophased controlled soft starters used for soft starting three-phase AC motors for applications with a normal operating frequency and a performance range of 3 to 200 A (1.1 to 110 kW with a 400 V mains voltage). Closing transients and DC components during startup are effectively suppressed and guarantee even motor starting. The special actuation method (asymmetrical trigger phase control) for the soft starter function avoids the DC components (Eaton patent) that would normally occur in two-phasecontrolled soft starters. This suppresses the generation of an elliptical rotating field, which would cause uneven motor starting and increase the motor's acceleration. The true run behavior of the DS7 is therefore comparable with that of a three-phase controlled soft starter. • The ramp time can be adjusted by potentiometer within a range of 1 to 30 s (for starting) or 0 to 30 s (for stopping) with a potentiometer • The start voltage (or start torque) can be adjusted within a range of 30 to 100 percent of the mains voltage with a potentiometer • Significant reduction in switch-on current, achieved with a short soft start ramp time (min. 1 s) for lamp and heating loads • Internal bypass relay: switches on automatically after the end of the ramp, bypassing the internal thyristors. • This makes it possible to comply with radio interference level B without any additional measures. • The motor's thermal load is smaller than it would be without asymmetric ignition control. • Designed specifically for long cables Functions Documentation Typical fields of application for Series DS7 soft starters are: • Pump drives: pressure surges are prevented through soft starting. The mechanical load on the whole plant is reduced and its service life increases. • Fan drives: soft starting keeps fan belts from slipping, preventing premature wear. This lowers operating costs and extends the system's lifespan. • Conveyor belts: conveyor belts start running smoothly, instead of starting with a jolt. This ensures that any goods being conveyed do not topple over. Mechanical damage to the belt itself is avoided, making it more durable. Surface mounting and standard mounting procedures are described in the corresponding mounting instructions and in the manual. CA04020001Z-EN-INT www.eaton.eu Instructional leaflets: IL03902003Z: for size 1 devices (up to 12 A motor output) IL03902004Z: for size 2 devices (up to 32 A motor output) IL03902005Z: for size 3, 4 devices (up to 200 A motor output) Manual: MN03901001Z You can download the documentation for the DS7 soft starters from the Internet at: www.moeller.net/support Communication interface SmartWire-DT Our SmartWire-DT interface completely eliminates the need for conventional control wiring. This has several advantages: • No incorrect wiring • Faster wiring • Cost saving The interface can be used to send control commands to the DS7-SWD and change and diagnose its parameter configuration; in addition, the control electronics can be powered via the SmartWire-DT cable. The device is controlled with one of three selectable profiles: • A "start/stop" profile, which should already be familiar from the PKE motor-protective circuit-breaker and contactor combination • An 8 bit-wide profile for the soft starter, which is provided the same way for the variable frequency drive and features more options • A control profile comparable to a PROFIdrive profile, just like the one available for the variable frequency drive. Regardless of the profile chosen, the DS7-SWD's parameters can be read and written to at any time by using acyclic services. DS7-SWD makes it possible to read and write to all device parameters. The mechanisms of the parameter channel that is described for the drives in the PROFIdrive profile are used for this purpose. This profile provides a standardized parameter access method for variable frequency drives and soft starters. It is also possible to overwrite the potentiometer settings on the DS7-SWD, which can come in handy, for instance, when a change made to the machine needs to be undone. The DS7-SWD comes with a detailed diagnostic system with options that extend far beyond those of wired devices. In addition to having an error log, the DS7-SWD can detect and report nine different device faults. A warning parameter reports any present alarm messages. Moreover, the response to each individual fault can be customized. Finally, there are 35 additional messages for communication errors. Using the DS7 in connection with the PKE opens up new functionalities that were previously thought impossible to implement with a low-cost soft starter and that were reserved to significantly more expensive devices. Combining a PKE unit and a DS7-SWD makes it possible to completely protect the DS7-SWD device against overloads. In addition, it provides a current limiting function and can report thermal capacity utilization levels to higher level controllers. Expanded temperature range DS7-340SX…-L soft starters can operate at temperatures as low as -40 °C. DS7 soft starters 111 Basic devices Ordering Basic devices Rated operational current Device (AC53) Ie Assigned motor rating at 400 V, 50 Hz P at 480 V, 60 Hz P A kW HP Part no. Article no. Price see price list Part no. Article no. Price see price list UC 24 V AC/DC Us 24 V AC/DC Standard temperature range UC 24 V AC/DC Us 24 V AC/DC Expanded temperature range down to -40 °C Std. pack Soft starters Soft starters for three-phase loads Mains supply voltage (50/60 Hz) ULN 200 - 480 V AC 1.5 2 DS7-340SX004N0-N 134847 DS7-340SX004N0-L 171740 7 3 5 DS7-340SX007N0-N 134849 DS7-340SX007N0-L 171741 9 4 5 DS7-340SX009N0-N 134910 DS7-340SX009N0-L 171742 12 5.5 10 DS7-340SX012N0-N 134911 DS7-340SX012N0-L 171743 16 7.5 10 DS7-340SX016N0-N 134912 DS7-340SX016N0-L 171744 24 11 15 DS7-340SX024N0-N 134913 DS7-340SX024N0-L 171745 32 15 25 DS7-340SX032N0-N 134914 DS7-340SX032N0-L 171746 41 22 30 DS7-340SX041N0-N 134916 DS7-340SX041N0-L 171747 55 30 40 DS7-340SX055N0-N 134917 DS7-340SX055N0-L 171748 70 37 50 DS7-340SX070N0-N 134918 DS7-340SX070N0-L 171749 81 45 60 DS7-340SX081N0-N 134919 DS7-340SX081N0-L 171750 100 55 75 DS7-340SX100N0-N 134920 DS7-340SX100N0-L 171751 135 75 100 DS7-340SX135N0-N 134921 DS7-340SX135N0-L 171752 160 90 125 DS7-340SX160N0-N 134922 DS7-340SX160N0-L 171753 200 110 150 DS7-340SX200N0-N 134923 DS7-340SX200N0-L 171754 UC 110 - 230 V AC Us 110/230 V AC 1 off DS7 4 UC 24 V DC Us 24 V DC 4 1.5 2 DS7-342SX004N0-N 134925 DS7-34DSX004N0-D 134943 7 3 5 DS7-342SX007N0-N 134927 DS7-34DSX007N0-D 134945 9 4 5 DS7-342SX009N0-N 134928 DS7-34DSX009N0-D 134946 12 5.5 10 DS7-342SX012N0-N 134929 DS7-34DSX012N0-D 134947 16 7.5 10 DS7-342SX016N0-N 134930 DS7-34DSX016N0-D 134948 24 11 15 DS7-342SX024N0-N 134931 DS7-34DSX024N0-D 134949 32 15 25 DS7-342SX032N0-N 134932 DS7-34DSX032N0-D 134950 41 22 30 DS7-342SX041N0-N 134934 DS7-34DSX041N0-D 134952 55 30 40 DS7-342SX055N0-N 134935 DS7-34DSX055N0-D 134953 70 37 50 DS7-342SX070N0-N 134936 DS7-34DSX070N0-D 134954 81 45 60 DS7-342SX081N0-N 134937 DS7-34DSX081N0-D 134955 100 55 75 DS7-342SX100N0-N 134938 DS7-34DSX100N0-D 134956 135 75 100 DS7-342SX135N0-N 134939 DS7-34DSX135N0-D 134957 160 90 125 DS7-342SX160N0-N 134940 DS7-34DSX160N0-D 134958 200 110 150 DS7-342SX200N0-N 134941 DS7-34DSX200N0-D 134959 Notes 1 off Information relevant for export to North America UL/CSA applies only for DS7…-N Product Standards UL File No. CSA File No. CSA Class No. Suitable for Max. Voltage Rating Degree of Protection 4 - 12 A 16 - 32 A 41 - 100 A IEC/EN 60947-4-2; GB 14048.6; UL 508; CSA-C22.2 No 0-M91; CSA-C22.2 No 14-05 CE marking E251034 2511305 321106 Branch circuits 480 V IP20; UL/CSA Type 1 135 - 200 A CA04020001Z-EN-INT www.eaton.eu 112 DS7 soft starters Accessories Accessories Frame size For use with Part no. Article no. DIN 43653, 690/700 V (IEC/UL) Inside micrometer 80 mm 16 5.5 000 DS7-34…SX004N0-… 25 9 000 DS7-34…SX007N0-… 32 10 000 40 12 000 DS7-34…SX009N0-… DS7-34…SX012N0-… DM4-340-7K5 50 15 000 170M1359 171968 170M1361 171969 170M1362 171970 170M1363 171971 170M1364 171972 63 16 000 80 19 000 100 21 S1* 125 25 000 Rated device current Maximum power loss Pv A W Price see price list Std. pack Information relevant for export to North America 1 off Product Standards Superfast semiconductor fuses DS4-340-2K2-M DS4-340-2K2-MR DS4-340-2K2-M-DC DS7-34…SX016N0-… DS4-340-4K0-M DS4-340-4K0-MR DS4-340-7K5-MX DS4-340-7K5-MXR DS7-34…SX024N0-… DS4-340-5K5-M DS4-340-5K5-MR DS4-340-11K-MX DS4-340-11K-MXR DS7-34…SX032N0-… DS6-340-22K-MX DM4-340-22K DM4-340-30K UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Suitable for 170M1365 171973 30 S1* 200 45 S1 315 58 S1 350 60 S1 400 65 S2 450 70 S1 500 72 S1 500 95 S3 630 80 S1 900 120 S3 1250 140 S3 CA04020001Z-EN-INT www.eaton.eu DS4-340-11K-M DS4-340-11K-MR DM4-340-37K DM4-340-45K DS6-340-37K-MX DS6-340-45K-MX DS6-340-55K-MX DS7-34…SX070N0-… DS7-34…SX081N0-… DS7-34…SX100N0-… DS6-340-75K-MX DS7-34…SX135N0-… DM4-340-55K DM4-340-75K DS6-340-90K-MX DS7-34…SX160N0-… DM4-340-90K DM4-340-110K DM4-340-132K DM4-340-160K DS6-340-110K-MX DS7-34…SX200N0-… DM4-340-132K DM4-340-160K DM4-340-200K DM4-340-250K DM4-340-315K DM4-340-400K DM4-340-500K JFHR2 053787_C_000 1422-30 UL recognized, CSA certified semiconductor protection 170M1366 171974 170M3012 171976 170M2615 171975 Product Standards UL File No. UL Category Control No. North America Certification Suitable for 160 IEC/EN 60269-4; UL 248-1; CSAC22.2 No. 248.14; CE marking E125085 170M3014 171977 170M4008 171978 170M4010 171979 170M4011 171980 170M5008 171984 170M4013 171981 170M4014 171982 170M6008 171985 170M4016 171983 170M6013 171986 170M6016 171987 Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Suitable for IEC/EN 60269-4; UL 248-1; CE marking E125085 JFHR2 UL recognized semiconductor protection IEC/EN 60269-4; UL 248-1; CSAC22.2 No. 248.14; CE marking E125085 JFHR2 053787_C_000 1422-30 UL recognized, CSA certified semiconductor protection DS7 soft starters 113 Accessories For use with Part no. Article no. 000, 00 170H1007 171988 Price see price list Std. pack Information relevant for export to North America 1 off Product Standards Fuse Bases Dimensions (W x H x D) mm 145 x 43 x 50 205 x 88 x 80 S1*, S1, S2, S3 UL File No. UL Category Control No. North America Certification Suitable for 170H3004 171989 IEC/EN 60269-1; UL 512; CE marking E14853 IZLT2 UL listed DIN 43653 fuses Overload relays DS7-34…SX004… DS7-34…SX007… DS7-34…SX009… DS7-34…SX012… DS7-34…SX016… DS7-34…SX024… 1 off PKZM0-XDM12 283149 1 off Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Suitable for Max. Voltage Rating Degree of Protection UL 508; CSA-C22.2 No. 14; IEC/EN 60947-4-1; IEC/EN 60947-5-1; CE marking E29184 NKCR 12528 3211-03 UL listed, CSA certified Branch circuits 600 V AC IEC: IP20, UL/CSA Type: - DS7 DS7-34…SX032… ZB12-4 278438 ZB12-10 278440 ZB12-12 278441 ZB32-16 278452 ZB32-24 278453 ZB32-32 278454 Wiring set For DOL Starter DS7-34…SX004… DS7-34…SX007… DS7-34…SX009… DS7-34…SX012… Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking E36332 NLRV 165628 3211-05 UL listed, CSA certified Electric contact module DS7-34…SX016… DS7-34…SX024… DS7-34…SX032… PKZM0-XM32DE 239349 5 off Product Standards DS7-34…SX004… DS7-34…SX007… DS7-34…SX009… DS7-34…SX012… DILM12-XMCP/T 121770 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL Category Control No.NLRV CSA File No. 165628 CSA Class No. 3211-05 North America Certification UL listed, CSA certified Motor feeder plug North America Certification IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking Request filed for UL and CSA Busbar adapters PKZM0, PKE + DS7...004N... PKZM0, PKE + DS7...007N... PKZM0, PKE + DS7...009N... PKZM0, PKE + DS7...012N... PKZM0, PKE + DS7...016N... PKZM0, PKE + DS7...024N... PKZM0, PKE + DS7...032N... BBA0L-25 142526 1 off BBA0L-32 142527 1 off PKZM0, PKE + DS7...004N... PKZM0, PKE + DS7...007N... PKZM0, PKE + DS7...009N... PKZM0, PKE + DS7...012N... PKZM0, PKE + DS7...016N... PKZM0, PKE + DS7...024N... PKZM0, PKE + DS7...032N... PKZM0-XC45L 142529 1 off PKZM0-XC45L/2 142570 1 off Top-hat rail adapter 45 mm wide adapter plate CA04020001Z-EN-INT www.eaton.eu 114 DS7 soft starters Accessories Std. pack Notes Information relevant for export to North America 5 off For the primary side of DS7 Suitable for 3 DS7 soft starters Length 112 mm For the primary side of DS7 Suitable for 4 DS7 soft starters Length 157 mm For the primary side of DS7 Suitable for 5 DS7 soft starters Length 202 mm Product StandardsIEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E36332 UL Category Control No. NLRV CSA File No. 012528 CSA Class No. 2411-03 North America Certification UL listed, CSA certified DILM12-XEK 240083 5 off For three-phase commoning link, protected against accidental contact, Ue = 690 V, Iu = 35 A. Connection cross section: Stranded 2.5…16 mm2 Flexible with ferrule 2.5…16 mm2 AWG14…8 Product StandardsIEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E36332 UL Category Control No. NLRV CSA File No. 012528 CSA Class No. 2411-03 North America Certification UL listed, CSA certified NZM1-XKSFA 100780 1 off DS7-34…SX135… DS7-34…SX160… DS7-34…SX200… NZM2-XKSFA 104640 1 off DS7-34…SX135… DS7-34…SX160… DS7-34…SX200… NZM2-XKSA 260038 1 off Type contains parts for a terminal located at top or bottom for 3 pole circuitbreakers. Enhancement of the busbar tag shroud (simple protection against contact with a finger). Cannot be combined with NZMXSTK control circuit terminal. Type contains parts for a terminal located at top or bottom for 3 pole circuitbreakers. Enhancement of the busbar tag shroud (simple protection against contact with a finger). Protection when reaching into the cable connection area with the connection of cables in the box terminal. With 2 conductors max cross section 22 mm2 or AWG4. Cannot be combined with NZMXSTK control circuit terminal. Type contains parts for a terminal located at top or bottom for 3 pole circuitbreakers. Busbar tag shroud where cable lugs, busbars or tunnel terminals are used. When using insulated conductor material to IP1X. For use with Part no. Article no. Price see price list Three-phase commoning links For the primary side of DS7 Suitable for 3 DS7 soft starters Length 112 mm protected against accidental contact, shortcircuit proof, Ue = 690 V, Iu = 35 A can be extended by rotating by mounting DS7-34…SX004… DS7-34…SX007… DS7-34…SX009… DS7-34…SX012… DILM12-XDSB0/3 240084 DILM12-XDSB0/4 240085 DILM12-XDSB0/5 240086 Incoming connection block 6 T2 L2 4 3 5 T1 T3 L3 2 1 L1 DS7-34…SX004… DS7-34…SX007… DS7-34…SX009… DS7-34…SX012… Terminal cover Type contains parts for a terminal located at top or bottom for 3 pole circuit-breakers. Enhancement of the busbar tag shroud (simple protection against contact with a finger). Cannot be combined with NZM-XSTK control circuit terminal. knockout DS7-34…SX041… For box terminal DS7-34…SX055… DS7-34…SX070… DS7-34…SX081… DS7-34…SX100… knockout Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Suitable for CA04020001Z-EN-INT www.eaton.eu UL489; CSAC22.2 No. 5-09; IEC60947, CE marking E31593 DIHS 22086 1432-01 UL listed, CSA certified Refer to main component information DS7 soft starters 115 Accessories Accessories For use with Part no. Article no. Price see price list Std. pack Notes Information relevant for export to North America NZM2-XIPK 266773 1 off NZM2-XIPA 266777 1 off Type contains parts for a terminal located at top or bottom for 3 pole circuitbreakers. Enhancement of the busbar tag shroud to IP2X. Protection when reaching into the cable connection area with the connection of cables in the box terminal. With 2 conductors max cross section 25 mm2 or AWG4. Cannot be combined with NZM-XSTK control circuit terminal. Type contains parts for a terminal located at top or bottom for 3 pole circuitbreakers. Enhancement of the busbar tag shroud to IP2X. When mounting NZM2-..(C)NA or NZM...-NA the following applies: with 2 conductors max cross section 25 mm2 or AWG4. DE6-MNT-NZM 107323 1 off DS7-FAN-032 135553 1 off DS7-FAN-100 169021 1 off DS7-FAN-200 169022 1 off PKE32-COM 168970 1 off Typ enthält Teile für eine Schalterseite oben oder unten für 3-polige Schalter. Erhöhung des Berührungsschutzes auf IP2X. For box terminal NZM2, PN2, N(S)2 for cover NZM2-XKSA or NZM2 or NZM2...(C)NA und N(S)2...NA NZM2, PN2, N(S)2 DS7 IP2X protection against contact with a finger Mounting kit when using covers NZM1-XKSFA and NZM2-XKSA DS7-34xSX041N0-x DS7-34xSX055N0-x DS7-34xSX070N0-x DS7-34xSX081N0-x DS7-34xSX100N0-x DS7-34xSX135N0-x DS7-34xSX160N0-x DS7-34xSX200N0-x - Device fans Device fan for increasing the load cycle (more starts per hour higher or longer-lasting starting current) DS7-34…SX004… DS7-34…SX007… DS7-34…SX009… DS7-34…SX012… DS7-34…SX016… DS7-34…SX024… DS7-34…SX032… DS7-34…SX041… DS7-34…SX055… DS7-34…SX070… DS7-34…SX081… DS7-34…SX100… DS7-34…SX135… DS7-34…SX160… DS7-34…SX200… North America Certification Request filed for UL and CSA PKE communications cable 6-Pole Prefabricated with two plugs For connecting the PKE to DS7-SWD DS7…SWD CA04020001Z-EN-INT www.eaton.eu 116 DS7 soft starters General information on Engineering Engineering General information on Engineering Generalized phase control of motor voltage By means of generalized phase control, the soft starter adjusts the grid's voltage (ULNsmoothly from an adjustable start value to 100 % of the rated value ULN . In DS7 and S801+/S811+ series soft starters, generalized phase control is achieved with anti-parallel thyristors that are bypassed for continuous operation by using bypass contacts (TOR = Top Of Ramp) after the time for a time-triggered voltage change (t-Start) has elapsed. The transition resistance of these bypass contacts is considerably lower than the transition resistance of the power semiconductors. This reduces the heat dissipation in the soft starter and extends the lifespan of the power semiconductors. As well as the time-controlled startup of a motor, the soft starter also enables a time-controlled reduction of the motor voltage and thus a controlled stopping of the motor. U ULN TOR U-Start U-Start t t-Start t t-Start ULN:Mains supply voltage U-Start: start voltage t-Start: Ramp time of the voltage change at start TOR (Top of Ramp): Signals the end of the set "t-Start" ramp time (output voltage U2 = Mains supply voltage ULN). The internal bypass contacts are closed after this. This voltage control enables the inrush current of a three-phase asynchronous motor to be limited and its starting torque to be reduced. This enables a smooth and jerk-free increase in torque, adjusted in line with the machine's load behavior. This has a positive effect on the lifespan, operating behavior, and operating processes of the mechanical equipment and prevents negative effects such as: • Impacting of cog edges in the gearbox • Pressure surge in pipe systems (water impact), • Slipping of V belts or • Jitter with conveyor systems. CA04020001Z-EN-INT www.eaton.eu t-Stop The output voltage of a soft starter determines the torque of the motor (M ~ U2). Because of this, it is necessary to make sure that, when a machine starts up, the selected U-Start start voltage is not too low and the t-Start ramp time for the linear voltage change is set to be as short as possible. Please note: • Long ramp times (t-Start) will produce a soft startup behavior, but will also result in a higher thermal load on the thyristors • A high start voltage (U-Start) will produce a higher torque and a high starting current • Set the lowest possible start voltage and the shortest possible start ramps. The following pages include application and setting configuration examples for DS7 soft starters. If controlled deceleration is required, t-Stop must be set to a longer time than would be necessary for the machine to coast freely based on the load. For the thyristors, the controlled deceleration constitutes a load comparable to that produced during startup. If, for example, the deceleration ramp is activated on a soft starter with a maximum of 10 permissible starts per hour, the number of permissible starts will be reduced to five per hour (plus five stops within that hour). DS7 soft starters 117 General information on Engineering Selection criteria U, I, f When different operating frequencies, run-up times and/or starting currents are involved, the thermal capacity of the DS7 soft starter must be taken into account in the design. This can be done by using the following diagrams or by calculating the I2t values. These I2t values define the corresponding load capacity and overload cycle and are defined in product standard IEC/EN 60947-4-2. ① DS7-34…SX032…soft starter: • 32A: AC-53a: 3-5: 75-10 • Rated operational current (Ie) 32 A • Load cycle AC-53a • 300% overcurrent for 5 seconds • 75% duty factor with 10 starts per hour ③ The resulting I2t value is: (3 x 32 A)2 x 5 s = 46.080 A2s The maximum I2t value of the connected motor load must be smaller: (3 x 29 A)2 x 5 s = 37.845 A2s Soft starter DS7-34…SX032… is the right choice for this application. ② 230 / 400 V ∆ / 1.1 kW 1430 min-1 4.6 / 2.6 A cos ϕ 0.81 50 Hz If the motor had a higher inrush current, e.g., 5 times the starting current, a more powerful soft starter would have to be selected: • Motor inrush current: ILRP = 5 x 29 = 145 A, I2t value = (5 x 29 A)2 x 5 s = 105.125 A2s • DS7-34…SX041…: 41A: AC-53a: 3-5: 75-10 => (3 x 41 A)2 x 5 s = 75.645 A2s Soft starter DS7-34…SX041… cannot meet the required startup and load conditions required in this case. 30 s SX041 1/h SX041 10/h SX041 20/h 25 s DS7 20 s 15 s 10 s Soft starters ③ are selected based on the supply voltage of the corresponding grid ① (ULN) and the rated operational current of the assigned motor ②. The motor's circuit configuration (Δ/Y) must be selected in such a way that it matches the supply voltage. In addition, the soft starter's rated operational current (Ie) must be at least equal to that of the motor. 5s s 60 A 80 A 70 A 100 A 90 A 120 A 110 A 140 A 130 A 150 A Additional selection criteria include: • Ambient air temperature (rated value +40 °C) • The number of starts per hour (< 10 starts, take stops into account) • Load torque (quadratic, linear) • Starting torque DS7-34…SX055…: 55A: AC-53a: 3-5: 75-10 => (3 x 55 A)2 x 5 s = 136.125 A2s Soft starter DS7-34…SX055…, however, does meet the required startup and load conditions. Centrifugal pumps, centrifugal fans, simple and smooth-running conveyor belts and traction drives, and circular saws and ribbon saws are some of the typical applications for which soft starters are used. Reciprocating compressors, mixers, mills, crushers, and lifting gear are instead categorized as heavy starting duty machines. In this case, the soft starter must be oversized in terms of its overload capacity. Note: As the following diagram shows, the DS7-34…SX055… unit can handle even more demanding startup and load requirements, e.g., up to 20 starts per hour and longer start-up times (up to 10 seconds). 30 s In the case of applications that are typical for a soft starter, such as water pumps (centrifugal pumps), and that feature comparable operational data (operating frequency, run-up time, and/or inrush currents) a soft starter can be assigned directly to the motor on the basis of the rated operational current. 25 s Example: • 15 kW Pump motor • 400 V • Rated operational current 29 A • About three times the starting current (ILRP = 87 A), • A maximum of 10 starts per hour • 5-second start-up time • ambient air temperature 40 °C. 15 s SX055 1/h SX055 10/h SX055 20/h 20 s 10 s 5s s 80 A 100 A 120 A 140 A 160 A 180 A 200 A => DS7-34…032… (Ie = 32 A) 30 s 10/h 1/h 20/h 25 s 20 s 15 s 10 s 5s s 32 A 64 A 96 A 128 A 160 A CA04020001Z-EN-INT www.eaton.eu 118 DS7 soft starters Design with different load cycles Design with different load cycles DS7-34...SX041N0-... DS7-34...SX055N0-... 30 s 22K 1/h 22K 10/h 25 s 22K 20/h 20 s 30 s 15 s 10 s 10 s 5s 5s 60 A 70 A 80 A 90 A 100 A 110 A 120 A 130 A 140 A s 150 A DS7-34...SX070N0-... 37K 1/h 37K 10/h 25 s 37K 20/h 20 s 10 s 5s 5s 150 A 175 A 200 A 225 A 250 A DS7-34...SX100N0-... 55K 1/h 55K 10/h 25 s 55K 20/h 20 s s 100 A 200 A 45K 20/h 125 A 150 A 175 A 200 A 225 A 250 A 25 s 20 s 15 s 10 s 10 s 5s 5s s 150 A 175 A 200 A 225 A 250 A 275 A 300 A 325 A 350 A DS7-34...SX160N0-... 275 A 300 A 75K 1/h 75K 10/h 75K 20/h s 125 A 175 A 225 A 275 A 325 A 375 A 425 A 475 A 525 A 150 A 200 A 250 A 300 A 350 A 400 A 450 A 500 A 550 A DS7-34...SX200N0-... 30 s 90K 1/h 90K 10/h 25 s 90K 20/h 20 s 30 s 25 s 20 s 15 s 15 s 10 s 10 s 5s 5s 300 A 350 A 400 A 450 A 500 A 550 A 600 A 650 A www.eaton.eu 110K 1/h 110K 10/h 110K 20/h s 200 A 300 A 400 A 500 A 600 A 700 A 800 A 250 A 350 A 450 A 550 A 650 A 750 A Additional diagrams for 4-32 A soft starters can be found in the manual for DS7 soft starters (MN03901001Z). CA04020001Z-EN-INT 180 A 45K 1/h 45K 10/h 30 s 15 s Note: 160 A DS7-34...SX135N0-... 30 s 200 A 140 A 20 s 10 s 250 A 120 A 25 s 15 s s 150 A 100 A 30 s 15 s 125 A 80 A DS7-34...SX081N0-... 30 s s 100 A 30K 20/h 20 s 15 s s 30K 1/h 30K 10/h 25 s DS7 soft starters 119 Potentiometer settings Setting of potentiometer Potentiometer settings U I U (R) (AC11 (L) 250 V ∼ 30 V H 0.2 A 0.7 A 1A 0.5 A Imin Umin 10 mA 100 mA 250 V ∼ 5VH U-Start TOR RUN t-Start t-Stop TOR t RUN 13 14 23 24 13 14 (Top Of Ramp) 23 24 U-Start (%) t-Start (s) ∼10 U-Start % ∼30 10 t-Stop (s) t-Stop (s) 0 10 20 1 30 30 ∼25 0 100 ∼30 10 1 30 30 1 30 10 30 30 1 10 30 30 10 10 30 30 ∼10 ∼60 10 10 30 30 ∼10 ∼60 10 30 10 30 100 20 0 Bulk conveyor Escalator 30 0 20 1 20 0 100 Tunnel fan Axial fan → a Soft starter DS7 should have a higher rating than the assigned motor. 30 0 20 1 20 0 100 J→∞ Large gyrating mass → The DS7 soft starter's rating should be higher than the assigned motor output. 30 0 20 1 20 0 100 ∼50 Fan general (building) with belt drive 30 0 20 ∼15 20 0 100 ∼40 10 30 0 20 ∼18 20 0 100 ∼40 1 Centrifugal pump 10 30 10 30 ∼20 20 ∼15 20 0 100 ∼30 10 Roller conveyers 10 30 ∼10 30 0 20 1 20 0 100 ∼40 10 Conveyor belt with loose belt 10 30 J→0 Low flywheel mass 30 ∼30 20 ∼20 20 DS7 t-Start (s) Mixers Agitators → a Soft starter DS7 should have a higher rating than the assigned motor. 30 CA04020001Z-EN-INT www.eaton.eu 120 DS7 soft starters Connection examples Connection examples Standard connection up to 12 A L1 L2 L3 PE Q1 I> I> I> 5L3 3L2 1L1 F3 TOR 6T3 4T2 2T1 Q21 + Us - A2 + A1 13 Q1 M 3~ M1 (+) Us (–) Us 24 V AC/DC, 120/230 V AC Standard connection up to 32 A L1 L2 L3 PE Q1 I> I> I> 5L3 3L2 1L1 F3 TOR RUN 6T3 4T2 2T1 Q21 - Us + Us - A2 + A1 13 14 23 24 S3 Q1 M 3~ M1 (+) Us (–) Us CA04020001Z-EN-INT www.eaton.eu 24 V AC/DC, 120/230 V AC DS7 soft starters 121 Connection examples Standard connection 41 - 200 A With Emergency switching off function according to IEC/EN 60 204-1 and VDE 0113 Part 1 = EMERGENCY SWITCHING OFF L1 L2 L3 PE Q1 Q21 M1 F3 ① D2 U> ② ① ② D1 3.13 = Cable and motor protection (NZM (NZM1, NZM2) = Soft starter DS7 = Motor = superfast semiconductor fuse, optional for type 2 coordination (in addition to Q1) Control circuit terminal Undervoltage release with earlymake auxiliary contact Q1 3.14 I> I> I> PE 5L3 3L2 1L1 F3 RUN DS7 TOR PE 6T3 4T2 2T1 Q21 - Us + Us - A2 EN + A1 13 14 23 24 S3 M1 M 3~ Q1 (+) Us 24 V AC/DC, 110/230 V AC (–) Us CA04020001Z-EN-INT www.eaton.eu 122 DS7 soft starters DS7 soft starters Assigned switching and protective elements 123 Assigned switching and protective elements Assigned switching and protective elements Rated operational current1) assigned Motor output at 400 V P kW 480 V P HP 1.5 3 4 5.5 7.5 11 15 22 30 37 45 55 75 90 110 3.6 6.6 8.5 11.3 15.2 21.7 29.3 41 55 68 81 99 134 160 196 Soft starters Ie A_x 4 7 9 12 16 24 32 41 55 70 81 100 135 160 200 Soft starter function Soft starter function with soft stop in case of overload Mains contactor Semiconductor contactor (optional, in addition to the protective devices for type 1 coordination, required for type 2 coordination)5) Cable protection2) Type “1” coordination Cable protection2) Type “1” coordination optional4) Fuses Fuse holders Number x Part no. Number x Part no. 3 × 170M1359 3 × 170M1361 3 × 170M1362 3 × 170M1362 3 × 170M1364 3 × 170M1365 3 × 170M1366 3 × 170M1366 3 × 170M2615 3 × 170M4008 3 × 170M4008 3 × 170M4008 3 × 170M4011 3 × 170M5008 3 × 170M6008 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H3004 3 x 170H3004 3 x 170H3004 3 x 170H3004 3 x 170H3004 3 x 170H3004 Soft starters for three-phase mains connection, low operating frequency (5 s, 3 x Ie, 10 starts/h) DS7-34xSX004N0-x PKZM0-4 (+ CL-PKZ0) DS7-34xSX007N0-x PKZM0-10 (+ CL-PKZ0) DS7-34xSX009N0-x PKZM0-10 (+ CL-PKZ0) DS7-34xSX012N0-x PKZM0-12 (+ CL-PKZ0) DS7-34xSX016N0-x PKZM0-16 (+ CL-PKZ0) DS7-34xSX024N0-x PKZM0-25 (+ CL-PKZ0) DS7-34xSX032N0-x PKZM0-32 (+ CL-PKZ0) DS7-34xSX041N0-x NZMN1-M50 / PKZM4-50 DS7-34xSX055N0-x NZMN1-M63 / PKZM4-58 DS7-34xSX070N0-x NZMN1-M80 DS7-34xSX081N0-x NZMN1-M100 DS7-34xSX100N0-x NZMN1-M100 DS7-34xSX135N0-x NZMN2-M160 DS7-34xSX160N0-x NZMN2-M200 DS7-34xSX200N0-x NZMN2-M200 PKM0-4 (+ CL-PKZ0) PKM0-10 (+ CL-PKZ0) PKM0-10 (+ CL-PKZ0) PKM0-12 (+ CL-PKZ0) PZM0-16 (+ CL-PKZ0) PZM0-25 (+ CL-PKZ0) PZM0-32 (+ CL-PKZ0) NZMN1-M50 / PKZM4-50 NZMN1-M63 / PKZM4-58 NZMN1-M80 NZMN1-M100 NZMN1-M100 NZMN2-M160 NZMN2-M200 NZMN2-M200 overload relay3) ZB12-4 ZB12-10 ZB12-10 ZB12-12 ZB32-16 ZB32-24 ZB32-32 ZB65-40+ZB65-XEZ ZB65-57+ZB65-XEZ ZB150-70/KK ZB150-100/KK ZB150-100/KK ZB150-150/KK Z5-160/FF250 Z5-220/FF250 DILM7 DILM9 DILM9 DILM12 DILM17 DILM25 DILM32 DILM50 DILM65 DILM80 DILM95 DILM115 DILM150 DILM185 DILM225 1) Rated operational current based on the load cycle specified here. Used to specify the circuit-breaker required for the specified load cycle. At different duty cycles (operating frequency, overcurrent, overcurrent time, duty factor), this value changes and must then be adapted accordingly. 3) An external overload relay is required if the main contacts should not be disconnected in the event of an overload and a controlled soft stop is desired instead. 4) A mains contactor is not required. Disconnection characteristics in accordance with VDE can only be ensured with the specified circuit-breaker. 5) The superfast semiconductor fuses protect the soft starter from short circuits on the motor side. This can not, however, prevent damage caused by voltage peaks, for example through lightning strike. DS7 Notes 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 Motor Ie A_x Part no. Soft starters (device to be selected) 2) CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 124 DS7 soft starters DS7 soft starters Basic devices 125 Basic devices Technical data Basic devices DS7…004… DS7…007… DS7…009… DS7…012… DS7…016… DS7…024… DS7…032… DS7…041… DS7…055… DS7…070… DS7…081… DS7…100… DS7…135… DS7…160… DS7…200… 25 24 30 42 General Standards Approvals Approvals Climatic proofing DS7…-L IEC/EN 60947-4-2 UL 508 CSA22.2-14 CE IEC/EN 60947-4-2 UL 508 CSA22.2-14 CE UL CSA C-Tick UkrSEPRO Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 Cold test as per EN 60068-2-4 UL CSA C-Tick UkrSEPRO Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 Cold test as per EN 60068-2-4 -5 - +40 up to 60 at 2% derating per Kelvin temperature rise -40 - +40 up to 60 at 2% derating per Kelvin temperature rise -25 - +60 Ambient temperature ϑ °C ϑ °C -5 - +40 up to 60 at 2% derating per Kelvin temperature rise -40 - +40 up to 60 at 2% derating per Kelvin temperature rise -25 - +60 -40 - +60 m -40 - +40 up to 60 at 2% derating per Kelvin temperature rise 0 - 1000 m, above that 1 % derating per 100 m , up to 2000 m Vertical Vertical Protection type IP20 IP20 (terminals IP00) Integrated - Protection type IP40 can be achieved on all sides with covers from the NZM range. Finger- and back-of-hand proof Finger- and back-of-hand proof DS7…-L Storage DS7…-L Altitude Mounting position 0 - 1000 m, above that 1 % derating per 100 m , up to 2000 m DS7 Operation Degree of protection Protection against direct contact Rated insulation voltage 500 500 Overvoltage category/ pollution degree Shock resistance Ui V AC II/2 II/2 8 g/11 ms 8 g/11 ms Vibration resistance to EN 60721-3-2 Radio interference level (IEC/EN 55011) …342SX… 2M2 2M2 B B A Heat dissipation W Weight kg 0.2 A 0.35 0.45 0.6 0.8 1.1 1.5 7 10 13 18 …340SX…-N 0.35 0.4 1.8 1.8 3.7 …340SX…-L 0.44 0.49 0.44 1.8 3.7 …342SX… 0.4 0.45 0.4 1.8 3.7 …34DSX… 0.41 0.46 0.41 1.8 3.7 Main conducting paths Rated operating voltage Ue V AC 200 - 480 200 - 480 Supply frequency fLN Hz 50/60 50/60 Ie A 4 7 9 12 16 24 24 41 55 70 81 100 135 160 200 Rated operational current Device (AC-53) Assigned motor rating (Standard connection, In-Line) at 230 V, 50 Hz P kW 0.75 1.5 2.2 3 4 5.5 5.5 11 15 15 22 30 30 45 55 at 400 V, 50 Hz P kW 1.5 3 4 5.5 7.5 11 11 22 30 37 45 55 75 90 110 at 200 V, 60 Hz P HP 0.75 2 2 3 5 7.5 7.5 10 15 20 25 30 40 50 60 at 230 V, 60 Hz P HP 1 2 3 3 5 7.5 7.5 15 20 25 30 30 50 60 75 at 480 V, 60 Hz P HP 2 5 5 10 10 15 15 30 40 50 60 75 100 125 150 4 A: AC-53a: 3 - 5: 75 - 10 ✓ 7 A: AC-53a: 3 - 5: 75 - 10 ✓ 9 A: AC-53a: 3 - 5: 75 - 10 ✓ 12 A: AC-53a: 3 - 5: 75 - 10 ✓ 16 A: AC-53a: 3 - 5: 75 - 10 ✓ 24 A: AC-53a: 3 - 5: 75 - 10 ✓ 32 A: AC-53a: 3 - 5: 75 - 10 ✓ 41 A: AC-53a: 3 - 5: 75 - 10 ✓ 55 A: AC-53a: 3 - 5: 75 - 10 ✓ 70 A: AC-53a: 3 - 5: 75 - 10 ✓ 81 A: AC-53a: 3 - 5: 75 - 10 ✓ 100 A: AC-53a: 3 - 5: 75 - 10 ✓ 135 A: AC-53a: 3 - 5: 75 - 10 ✓ 160 A: AC-53a: 3 - 5: 75 - 10 ✓ 200 A: AC-53a: 3 - 5: 75 - 10 ✓ Overload cycle to IEC/EN 60947-4-2 AC-53a (without bypass) Internal bypass contacts CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 126 DS7 soft starters DS7 soft starters Basic devices 127 Basic devices DS7…004… DS7…007… DS7…009… DS7…012… DS7…016… DS7…024… DS7…032… DS7…041… DS7…055… DS7…070… DS7…081… DS7…100… DS7…135… DS7…160… DS7…200… PKM0-4 (+ CL-PKZ0) 3 x 170M1359 PKM0-10 (+ CL-PKZ0) 3 x 170M1361 PKM0-10 (+ CL-PKZ0) 3 x 170M1362 PKM0-12 (+ CL-PKZ0) 3 x 170M1362 PKM0-16 (+ CL-PKZ0) 3 x 170M1364 PKM0-25 (+ CL-PKZ0) 3 x 170M1365 PKM0-32 (+ CL-PKZ0) 3 x 170M1366 NZMN1-M50/ PKZM4-49 3 x 170M3012 NZMN1-M63/ PKZM4-57 3 x 170M2615 NZMN1-M80 NZMN1-M100 NZMN1-M100 NZMN2-M160 NZMN2-M200 NZMN2-M200 3 x 170M4008 3 x 170M4008 3 x 170M4008 3 x 170M4010 3 x 170M5008 3 x 170M6008 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H1007 3 x 170H3004 3 x 170H1007 3 x 170H3004 3 x 170H3004 3 x 170H3004 3 x 170H3004 3 x 170H3004 3 x 170H3004 Short-circuit rating Type “1” coordination Type “1” coordination Type „2“ coordination short-circuit rating (additional with the fuses for coordination type „1“) Fuse base (number x part no.) Terminal capacities Cable lengths Solid mm2 Flexible with ferrule mm2 Stranded mm2 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) - 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x 16 1 x (25 - 70) 2 x (6 - 25) - 1 x (4 - 185) 2 x (4 - 70) - 18 - 6 1 x (25 - 70) 2 x (6 - 25) 1 x (12 - 2/0) 1 x (4 - 185) 2 x (4 - 70) 1 x (12 - 350 kcmil) 2 x (12 - 00) Solid or stranded AWG 18 - 10 Copper band MM - - 2 x 9 x 0.89 x 9 x 0.8 Tightening torque Nm 1.2 3.2 6 (≤ 10 mm²); 9 (> 10 mm²) 5 (≤ 10 mm²); 14 (> 10 mm²) Screwdriver (PZ: Pozidriv) mm PZ2; 1 x 6 mm PZ2; 1 x 6 mm PZ2; 1 x 6 mm PZ2; 1 x 6 mm Solid mm2 Flexible with ferrule mm2 Stranded mm2 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) - Solid or stranded AWG 18 - 10 Tightening torque Nm 1.2 1 x (0.5 - 2.5) 2 x (0.5 - 1.0) 1 x (0.5 - 1.5) 2 x (0.5 - 0.75) 1 x (0.5 - 1.5) 2 x (0.5 - 1.0) 1 x (21 - 14) 2 x (21 - 18) 1.2 1 x (0.5 - 2.5) 2 x (0.5 - 1.0) 1 x (0.5 - 1.5) 2 x (0.5 - 0.75) 1 x (0.5 - 1.5) 2 x (0.5 - 1.0) 1 x (21 - 14) 2 x (21 - 18) 0.4 1 x (0.5 - 2.5) 2 x (0.5 - 1.0) 1 x (0.5 - 1.5) 2 x (0.5 - 0.75) 1 x (0.5 - 1.5) 2 x (0.5 - 1.0) 1 x (21 - 14) 2 x (21 - 18) 0.4 Screwdriver mm 0,8 x 5,5 1x6 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 DS7 Control cables Control circuit Regulator supply Notes External supply voltage Voltage Us V …340SX… 24 V AC/DC +10 %/- 15 % 24 V AC/DC +10 %/- 15 % …342SX… 110 V AC -15 % - 230 V AC +10 % 110 V AC -15 % - 230 V AC +10 % …34DSX… 24 V DC +10 %/- 15 % 24 V DC +10 %/- 15 % Current consumption Ie mA 50 50 IPeak mA/ms - 600/50 …340SX…-N 24 V DC +10 %/- 15 % 24 V DC +10 %/- 15 % …340SX…-L 24 V DC +10 %/- 15 % 24 V DC +10 %/- 15 % …34DSX… 24 V DC +10 %/- 15 % oder über SWD 24 V DC +10 %/- 15 % oder über SWD …340SX…-N 24 V AC +10 %/- 15 % 24 V AC +10 %/- 15 % …342SX…-N 110 V AC - 15 % - 230 V AC +10 % 110 V AC - 15 % - 230 V AC +10 % 1.6 1.6 4 4 17.3 - 27 17.3 - 27 …340SX… 17.3 - 27 17.3 - 27 …342SX… 108 - 253 108 - 253 Current consumption at peak performance (close bypass) at 24 V DC Digital inputs Control voltage DC-operated V DC AC operated V AC Current consumption 24 V External 24 V mA Current consumption 230 V 230 V AC mA …342SX… Pick-up voltage DC-operated V DC AC operated V AC CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 128 DS7 soft starters DS7 soft starters Basic devices 129 Basic devices DS7…004… DS7…007… DS7…009… DS7…012… DS7…016… DS7…024… DS7…032… DS7…041… DS7…055… DS7…070… DS7…081… DS7…100… DS7…135… DS7…160… DS7…200… Drop-out voltage DC operated V DC AC operated V AC 0-3 0-3 …340SX… 0-3 0-3 …342SX… 0 - 15 0 - 15 Pick-up time DC operated ms 250 250 AC operated ms 250 250 DC operated ms 350 350 AC operated ms 350 350 Drop-out time Relay outputs 1 (TOR) 2 (TOR, Ready) 2 (TOR, Ready) Voltage range Number V AC = Us 250 250 AC-11 current range A 1 A, AC-11 1 A, AC-11 1 A, AC-11 Acceleration s 1 - 30 1 - 30 Deceleration s 0 - 30 0 - 30 % 30 - 100 30 - 100 (0 - 8) x Ie (0 - 8) x Ie Fields of application Soft starting of three-phase asynchronous motors Soft starting of three-phase asynchronous motors 3-phase motors ✓ ✓ Fast switching (semiconductor contactor) Soft start function - (minimum ramp time 1s) - (minimum ramp time 1s) ✓ ✓ Reversing starter External solution required External solution required Suppression of closing transients Current limitation ✓ ✓ Soft start function Ramp times Start pedestal …34DSX…(+PKE) DS7 Current limitation Fields of application Functions …34DSX… ✓, with PKE ✓, with PKE Overload monitoring - - - - - - - - - - - - - - - Underload monitoring - - - - - - - - - - - - - - - Thermistor input - - - - - - - - - - - - - - - - - - - - - - - - - - - - Fault memory Faults …34DSX… 8 Pre-programmed parameter sets Suppression of DC components for motors Potential isolation between power and control sections Built-in interfaces …34DSX… CA04020001Z-EN-INT www.eaton.eu - 8 - ✓ ✓ ✓ ✓ SmartWire-DT SmartWire-DT CA04020001Z-EN-INT www.eaton.eu 130 DS7 soft starters Soft starters Dimensions Soft starters DS7-340SX004N0-N DS7-342SX004N0-N DS7-340SX041N0-N DS7-342SX041N0-N DS7-34DSX041N0-D DS7-340SX007N0-N DS7-342SX007N0-N DS7-340SX055N0-N DS7-342SX055N0-N DS7-34DSX055N0-D DS7-340SX009N0-N DS7-342SX009N0-N DS7-340SX070N0-N DS7-342SX070N0-N DS7-34DSX070N0-D DS7-340SX012N0-N DS7-342SX012N0-N DS7-340SX081N0-N DS7-342SX081N0-N DS7-34DSX081N0-D DS7-340SX100N0-N DS7-342SX100N0-N DS7-34DSX100N0-D DS7-34DSX004N0-D DS7-34DSX009N0-D DS7-34DSX007N0-D DS7-34DSX012N0-D 175 mm (6.89”) 45 mm (1.77”) ① 156 mm (6.14”) 161 mm (6.34”) 95 mm (3.74”) 4 x M4 PE 129 mm (5.08”) 125 mm (4.92”) 30 mm (1.18”) (1.18”) 22.5 mm (0.89”) 40 mm (1.58”) 35 mm (1.38”) 122 mm (4.80”) 130 mm (5.12”) 30 mm 35 mm (1.38”) 125 mm (4.92”) 122 mm (4.80”) 130 mm (5.12”) PE 22.5 mm (0.89”) 35 mm (1.38”) 4 x M4 ① 139 mm (5.47”) 93 mm (3.66”) ① DS7-...-D 95 mm (3.74”) 103 mm (4.05”) 45 mm (1.77”) DS7-340SX016N0-N DS7-342SX016N0-N DS7-340SX135N0-N DS7-342SX135N0-N DS7-34DSX135N0-D DS7-340SX024N0-N DS7-342SX024N0-N DS7-340SX160N0-N DS7-342SX160N0-N DS7-34DSX160N0-D DS7-340SX032N0-N DS7-342SX032N0-N DS7-340SX200N0-N DS7-342SX200N0-N DS7-34DSX200N0-D ① 195 mm (7.68”) 118 mm (4.65”) 45 mm (1.77”) 158 mm (6.22”) 200 mm (7.87”) 215 mm (8.46”) PE 40 mm (1.58”) 4 x M4 35 mm (1.38”) (0.59”) 140 mm (5.51”) 150 mm (5.90”) 35 mm 35 mm (1.38”) (1.38”) 15 mm ① DS7-34DSX016N0-D DS7-34DSX024N0-D DS7-34DSX032N0-D 2 x M4 35 mm (1.38”) CA04020001Z-EN-INT 52.5 mm (2.07”) 178 mm (7.01”) ① DS7-...-D 118 mm (4.65”) 45 mm (1.77”) 15 mm (0.59”) 108 mm (4.25”) 140 mm (5.51”) 150 mm (5.90”) PE 126 mm (4.96”) www.eaton.eu DS7 soft starters 131 Superfast semiconductor fuses, Fuse Bases Superfast semiconductor fuses, Fuse Bases Device fans 238 69 259 192 DS7-FAN-200 211 DS7-FAN-100 17 90 50 17 83 70 105 Superfast semiconductor fuses a1 a1 mm (inch) 20 (0.79) 28 (1.1) a2 mm (inch) 8 (0.31) 10 (0.39) Size (size) 000 00 a mm (inch) 104 (4.09) 108 (4.25) 108 (4.25) 109 (4.29) a1 mm (inch) 78 (3.07) 78 (3.07) 78 (3.07) 78 (3.07) a2 mm (inch) 50 (1.97) 50 (1.97) 50 (1.97) 51 (2.01) DS7 55 mm (2.17") 2 mm (0.08") a2 a mm (inch) 40 (1.57) 51 (2.01) 100 mm (3.9") 80 mm (3.15") a2 Sizes 000, 00 a 11 mm (0.43") 11 mm (0.43") a2 b b1 Sizes S1*, S1, S2, S3 6 mm (0.24") b b mm (inch) 45 (1.77) 53 (2.09) 61 (2.40) 76 (2.99) b1 mm (inch) 22 (0.87) 25 (0.98) 25 (0.98) 30 (1.18) Size (size) S1* S1 S2 S3 a1 a Fuse Bases 170H3004 170H1007 M10 M8 M10 40 mm (1.57) 85 mm (3.35") 126 mm (4.9") 80 mm (3.15") 146 mm (5.75") 25 mm (0.98") 80 mm (3.15") 205 mm (8.07") 4 x ⌀ 7 mm (4 x ⌀ 0.3") 150 mm (5.91") 50 mm (1.97) 9 mm (0.35") M8 64 mm (2.52") 77 mm (3.03") 25 mm (0.98") 43 mm (1.69") 40.5 mm (1.59") 50.5 mm (1.99") CA04020001Z-EN-INT www.eaton.eu S801+/S811+ Soft Starters – Powerful Performance in a Small Package The incredible performance of our two new S801+ and S811+ soft starter series is shaped by the expanded functionality that we have integrated into our tried-and-true series of soft starters. With only five sizes and rated operational currents of 37 A to 1,000 A for line voltages of 200 V to 690 V, the S801+ and S811+ are two of the smallest, most compact soft starters in the world. These three-phase controlled soft starters, which feature an internal bypass and extensive monitoring and protection mechanisms, guarantee not only soft motor start-ups, but also the safe and reliable continuous operation of three-phase motors even in applications involving high load torques. In addition, these soft starters can be connected with a standard in-line configuration or with an inside-the-delta (also called "six wire connection") configuration as needed. S801+ soft starters were designed with standard applications in mind and owe an important part of their appeal to their ease of use, while the devices in the S811+ series are characterized by a digital control and display unit that provides access to extended functions for sophisticated applications. Soft starter S801+, S811+ 133 System overview Soft starter S801+, S811+ 134 Description Soft starter S801+, S811+ 135 Key to type references, UL/CSA Soft starter S801+, S811+ 136 Ordering Soft starter S801+, S811+ 137 Accessories 139 Engineering Connection examples S811+...N3S 141 Technical data Soft starter S801+, S811+ 142 Dimensions 150 S801+, S811+ Soft starter S801+, S811+ CA04020001Z-EN-INT www.eaton.eu 134 Soft starter S801+, S811+ System overview 1 2 3 1 S801+ / S811+ → page 137 Fuse base for superfast semiconductor fuses 2 → page 111 Superfast semiconductor fuses → page 112 CA04020001Z-EN-INT www.eaton.eu 3 Soft starter S801+, S811+ 135 Description S811+ series soft starters provide all the features and characteristics of S801+ soft starters, plus expanded functionality and an operating unit (DIM = digital interface module). ONLN SS OXFDO1 H STOP S801+ soft starters are three-phase controlled and come with internal bypass contacts for continuous operation. With them, motors can be connected with a standard in-line circuit or inside the delta circuit (inside-the-delta circuit, √3 circuit). Using an inside-the-delta circuit will reduce the current flowing through the soft starter by approximately 42%. This makes it possible, for example, to start and run a motor with a rated operational current of 100 A using a 58-A soft starter. In addition, their comprehensive protection and monitoring features enable S801+ soft starters to ensure that three-phase motors with rated operational currents of 11 A to 1000 A will have soft startups and safe and reliable continuous operation at mains voltages of 200 V to 600 V – up to 690 V in the case of S811+ soft starters. Accordingly, for instance, their controlled coasting (soft stop control) and torque monitoring features can be used to prevent water impact in pumps and to reduce the mechanical loads on pump systems significantly. Essential features S801+ / S811+ • • • • • • • • • • • • • Rated operational current: 37 - 1000 A Parameterizable overload settings: 31–100% Adjustable overload classes: class 5, 10, 20, 30 Base setting: 15 s start ramp, 4 starts per hour, 300% starting current at 40 °C ambient temperature Allocated motor outputs for in-line connection: – 7.5 - 277 kW (3~ 230 V) – 18.5 - 525 kW (3~ 400 V) – 30 - 900 kW (3~ 690 V) Ambient air temperature: -30 °C to +50 °C any required mounting position Degree of protection with compact design (IP20 optional) 5 compact designs Adjustable torque control Adjustable kick start Efficient use of power achieved with internal bypass contacts during continuous operation 24-V control voltage: – External supply required – 1 A continuous current – 10 A starting current (peak value for 15 ms) Monitoring PREV NEXT ENTER S801+, S811+ S801+ series soft starters are an innovative addition that further enhances their tried-and-true predecessors. They are designed to guarantee reliable operation even under harsh and challenging ambient conditions. In addition, the series makes a compelling case as a result of its ease of use and is the perfect choice for standard applications such as pumps, fans, compressors, and conveyor belts. Important operating unit characteristics (S811+) • • • • • • • Language-neutral LCD display with backlight Easy to use and configure with function keys System parameter configuration Diagnostic and monitoring options Reading display (e.g., L1, L2, L3 phase currents) Error display Offset placement (mounted on door), connection via plug-in patch cord with RJ45 plug • Front IP54 S811+ specific characteristics • Mains voltage up to 690 V? • Special pump control algorithm with prolonged soft stop ramp S801+ specific characteristics • Microswitches and potentiometers make it easy to configure these soft starters CA04020001Z-EN-INT www.eaton.eu 136 Soft starter S801+, S811+ Key to type references S 801+ N 66 N 3 S S = soft starters S = Standard version Version Number of poles 801+ = with adjustable elements 811+ = with keypad 3 = Three-pole device Fitted with Frame size N = Basic device (S801+/S811+) P = Pump control (S811+) V = 690 V rated (S811+) N = 65 mm R = 110 mm T = 200 mm U = 200 mm V = 290 mm Rated operational current Ie 37 = 37 A 66 = 66 A 10 = 105 A 13 = 135 A 18 = 180 A 24 = 240 A 30 = 304 A 36 = 361 A 42 = 420 A 50 = 500 A 65 = 650 A 72 = 720 A 85 = 850 A 10 = 1000 A UL/CSA Information relevant for export to North America Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Conditions of Acceptability Suitable for Max. Voltage Rating Degree of Protection S801+N…, S801+R…, S801+T… (600 V) S811+N…, S811+R…, S811+T… (600 V) IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking E202571 NMFT LR 353 3211-06, 2411-01 UL Listed, CSA Certified None Branch Circuits, not as BCPD 600 Vac IP20 with kit Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA Certification Conditions of Acceptability Suitable for Max. Voltage Rating Degree of Protection S801+V…, 1000 A (600 V) S811+V…, 1000 A (600 V) IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking E202571 NMFT2 LR 353 3211-06 UL Recognized, CSA Certified 98-115 CFM fan and 4" x 4" vent req'd Branch Circuits, not as BCPD 600 Vac IP20 with kit CA04020001Z-EN-INT www.eaton.eu S801+U…, S801+V... bis 850 A (600 V) S811+U…, S811+V... bis 850 A (600 V) IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking E202571 NMFT LR 353 3211-06 UL Listed, CSA Certified None Branch Circuits, not as BCPD 600 Vac IP20 with kit S811+…V3S (690 V) IEC/EN 60947-4-2; UL 508; CE marking E202571 NMFT UL Listed None Branch Circuits, not as BCPD 690 Vac IP20 with kit Soft starter S801+, S811+ 137 Basic devices Ordering Basic devices Frame size Rated operational current Assigned motor rating Device (AC-53) at 400 V, 50 Hz at 480 V, 60 Hz Ie P P A kW HP Part no. Article no. Price see price list Std. pack Soft starters R T U V 25 S801+N37N3S 169852 66 30 50 S801+N66N3S 169853 105 55 75 S801+R10N3S 169854 135 75 100 S801+R13N3S 169855 180 90 150 S801+T18N3S 169856 240 132 200 S801+T24N3S 169857 304 160 250 S801+T30N3S 169858 361 200 300 S801+U36N3S 169859 420 200 350 S801+U42N3S 169860 361 200 300 S801+V36N3S 169863 420 200 350 S801+V42N3S 169864 500 250 400 S801+V50N3S 169865 650 315 500 S801+V65N3S 169866 720 400 600 S801+V72N3S 169867 850 450 600 S801+V85N3S 169868 1000 560 750 S801+V10N3S 169862 Soft starter for three-phase loads, with control unit N 37 18.5 R T U V 25 S811+N37N3S 168976 66 30 50 S811+N66N3S 168978 105 55 75 S811+R10N3S 168980 135 75 100 S811+R13N3S 168982 180 90 150 S811+T18N3S 168984 240 132 200 S811+T24N3S 168987 304 160 250 S811+T30N3S 168990 361 200 300 S811+U36N3S 169869 420 200 350 S811+U42N3S 169870 361 200 300 S811+V36N3S 168993 420 200 350 S811+V42N3S 168996 500 250 400 S811+V50N3S 168999 650 315 500 S811+V65N3S 169002 720 400 600 S811+V72N3S 169005 850 450 600 S811+V85N3S 169008 1000 560 750 S811+V10N3S 169011 Soft starter for three-phase loads, with control unit and pump algorithm N 37 18.5 R T U V Notes 25 S811+N37P3S 168977 66 30 50 S811+N66P3S 168979 105 55 75 S811+R10P3S 168981 135 75 100 S811+R13P3S 168983 180 90 150 S811+T18P3S 168985 240 132 200 S811+T24P3S 168988 304 160 250 S811+T30P3S 168991 361 200 300 S811+U36P3S 169872 420 200 350 S811+U42P3S 169873 361 200 300 S811+V36P3S 168994 420 200 350 S811+V42P3S 168997 500 250 400 S811+V50P3S 169000 650 315 500 S811+V65P3S 169003 720 400 600 S811+V72P3S 169006 850 450 600 S811+V85P3S 169009 1000 560 750 S811+V10P3S 169012 1 off 1 off S801+, S811+ Mains supply voltage (50/60 Hz) ULN: 200 - 600 V AC Supply voltage Us: 24 V DC Control voltage UC: 24 V DC, With internal bypass contacts Soft starters for three-phase loads N 37 18.5 1 off Information relevant for export to North America → Page 136 CA04020001Z-EN-INT www.eaton.eu 138 Soft starter S801+, S811+ Basic devices Frame size Rated operational current Device (AC-53) Assigned motor rating at 400 V, 50 Hz at 690 V, 50 Hz at 480 V, 60 Hz Ie P P P A kW kW HP Part no. Article no. Price see price list Std. pack Soft starters Mains supply voltage (50/60 Hz) ULN: 200 - 690 V AC Supply voltage Us: 24 V DC Control voltage UC: 24 V DC With internal bypass contacts Soft starter for three-phase loads, with control unit and pump algorithm, for 690-V grids T 180 90 160 150 240 V S811+T18V3S 168986 132 200 200 S811+T24V3S 168989 304 160 250 250 S811+T30V3S 168992 361 200 315 300 S811+V36V3S 168995 420 200 400 350 S811+V42V3S 168998 500 250 500 400 S811+V50V3S 169001 650 315 630 500 S811+V65V3S 169004 720 400 630 600 S811+V72V3S 169007 850 450 710 600 S811+V85V3S 169010 Notes Sizes S801+, S811+ L1 1 L2 3 L3 L1 1 5 N L2 3 L3 5 R T Information relevant for export to North America → Page 136 CA04020001Z-EN-INT www.eaton.eu U V 1 off Soft starter S801+, S811+ 139 Accessories Accessories Description For use with Part no. Article no. S801+ EMA71 144346 EMA91 144570 Price see price list Std. pack Information relevant for export to North America 1 off Product Standards Control unit With adjusting elements (potentiometer, microswitch) With illuminated LCD display With control buttons and function keys Front IP54 RJ45 plug, 8-pin S811+ IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking UL File No. E202571 CSA File No. LR 353 Conditions of Acceptability UL unlisted component, CSA Investigated Component Cover Protection for installation space in S811+ if the control unit is set up externally. S811+ EMA68 144556 1 off Mounting frame For mounting the EMA91 control unit externally with surface mounting (e.g., installation in control panel door). EMA91 EMA69A 144557 1 off Product Standards EMA69B 144558 EMA69C 144559 EMA69D 144560 1 off Product Standards S801+, S811+ EMA75 144561 1 off S801+, S811+, Baugröße N S801+, S811+, Baugröße R S801+, S811+, Baugrößen T und U S801+, S811+, Baugröße V SS-IP20-N 171990 SS-IP20-R 171991 SS-IP20-TU 171992 SS-IP20-V 158650 1 off IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking UL File No. E202571 UL Category Control No. NMFT2 CSA File No. LR 353 CSA Class No. 3211-06 North America Certification UL listed, CSA certified Connection cable EMA91 EMA91 EMA91 IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking UL File No. E202571 UL Category Control No. NMFT2 CSA File No. LR 353 CSA Class No. 3211-06 North America Certification UL listed, CSA certified Control terminal strip - IP20 Kits - CA04020001Z-EN-INT www.eaton.eu S801+, S811+ Connection cable with RJ45 plugs, 8 pole 140 Soft starter S801+, S811+ Accessories Description For use with Part no. Article no. S801+, S811+, Baugrößen T und U EML22 127661 Price see price list Std. pack Information relevant for export to North America 1 off Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Conditions of Acceptability Terminal blocks Tools with dimensions in inches required Terminal capacities 2 x 4-1/0MCM, 2 x 25-50 mm² EML23 127662 EML24 127663 EML25 127664 EML26 127665 4/0-500 MCM, 120-150 mm² 2 x 4/0-500 MCM, 2 x 120-150 mm² 2 x 2/0-300 MCM, 2 x 70-150 mm² 2/0-300 MCM, 70-150 mm² 4/0-500 MCM, 120-150 mm² S801+, S811+, Baugröße V EML27 144549 EML28 127666 EML30 127667 EML32 127668 EML33 127669 S801+, S811+, bis 600 V EMS39 127671 1 off S811+, bis 690 V EMS41 127672 1 off S801+, S811+ C441V 172306 1 off 2 x 4/0-500 MCM, 2 x 120-150 mm² 4 x 4/0-500 MCM, 4 x 120-150 mm² 6 x 4/0-500 MCM, 6 x 120-150 mm² 4 x 2/0-300 MCM, 4 x 70-150 mm² Max. Voltage Rating UL 1059 E60693 NMFT LR 353 6223-02 UL listed, CSA certified 10A min, Use group C or D, 30 to 12 AWG solid/stranded 300 Vac Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification UL508, CSA C22.2 No. 65 E202571 NMFT LR 353 6223-02 UL listed, CSA certified Product Standards UL File No. CSA File No. Conditions of Acceptability UL 508; CSA C22.2 No. 14 E202571 LR 353 UL and CSA Investigated Component 1000 Vac 3 ph TVSS SMD metal-oxide varistors (MOVs) with connection cables for the grid and motor connection sides Max. Voltage Rating EtherNet/IP - Modbus/TCP adapter - Product Standards UL File No. UL Category Control No. CSA File No. CSA Class No. Max. Voltage Rating CA04020001Z-EN-INT www.eaton.eu IEC/EN 60947-4-1; UL 508; CSA C22.2 No. 14; CE marking E1230 NKCR LR 353 3211-03 240 Vac (auxiliary contacts) Soft starter S801+, S811+ 141 Connection examples Engineering Connection examples Connection examples for S811+…N3S Standard connection (in-line connection) 4T2 6T3 Fault/Reset 2T1 Hand/Auto Q21 Jog 5L3 Start 3L2 L3 Enable 1L1 L2 (+) Us L1 (–) Us PE – + P 1 2 3 4 Ready/Fault TOR 13 14 95 96 98 a M 3~ M1 (+) Us (–) Us 24 V DC b ① Snap-on ferrite core, included as standard ② External control voltage (24 VDC) required, IS 100 mA, IPeak = 10 A for 15 ms when bypass contacts are switched Delta circuit (inside-the-delta circuit) Q1 S801+, S811+ L1 L2 L3 PE F1 I> I> I> Q11 F2 U1 V1 M 3~ U2 V2 Fault/Reset 6T3 Hand/Auto 4T2 Jog 2T1 Start Q21 Enable 5L3 (+) Us 3L2 (–) Us 1L1 – + P 1 2 3 4 TOR 13 14 Ready/Fault 95 96 98 ① W1 M1 (+) Us W2 (–) Us 24 V DC ② ① Snap-on ferrite core, included as standard ② External control voltage (24 VDC) required, IS 100 mA, IPeak = 10 A for 15 ms when bypass contacts are switched Short-circuit and cable protection: Q1 circuit-breakers or F1 fuses. CA04020001Z-EN-INT www.eaton.eu 142 Soft starter S801+, S811+ Soft starter S801+, S811+ Basic devices 143 Basic devices Technical data Basic devices S8x1+N37… S8x1+N66… S8x1+R10… S8x1+R13… S8x1+T18… S8x1+T24… S8x1+T30… S8x1+U36… S8x1+U42… IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 CE IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 CE CE CE CE CE UL CSA C-Tick CCC Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 UL CSA C-Tick CCC Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 General Standards Approvals Approvals Climatic proofing Ambient temperature Operation ϑ °C -30 - +50 -30 - +50 -30 - +50 -30 - +50 -30 - +50 -30 - +50 -30 - +50 -30 - +50 -30 - +50 Storage ϑ °C -50 - +70 -50 - +70 -50 - +70 -50 - +70 -50 - +70 -50 - +70 -50 - +70 -50 - +70 -50 - +70 m 0 - 2000 m, above that each 100 m 0.5% Derating As required As required As required Altitude Mounting position 0 - 2000 m, above that each 100 m 0.5% Derating As required As required As required As required As required Protection type IP20 (terminals IP00) IP20 (terminals IP00) IP20 (terminals IP00) IP20 (terminals IP00) IP20 (terminals IP00) Integrated Protection type IP40 can be achieved on all sides with covers SS-IP20-N. As required Degree of protection An IP20 degree of protection can be achieved on all sides by using optional terminal covers SS-IP20-TU. Protection against direct contact Finger- and back-of-hand proof Overvoltage category/pollution degree Shock resistance II/3 II/3 II/3 II/3 Finger- and back-of-hand proof II/3 II/3 II/3 II/3 II/3 15 g 15 g 15 g 15 g 15 g 15 g 15 g 15 g 15 g Radio interference level (IEC/EN 55011) Heat dissipation A A A A A A A A A W 25 25 25 25 25 25 25 25 25 Weight kg 2.6 2.6 4.8 4.8 18.6 18.6 18.6 18.6 18.6 V AC 200 - 600 200 - 600 200 - 600 200 - 600 200 - 600 200 - 600 200 - 600 200 - 600 200 - 600 - - - - 200 - 690 200 - 690 200 - 690 - - Rated operating voltage Ue …V3S Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Ie A 37 66 105 135 180 240 304 361 420 S801+, S811+ Main conducting paths Rated operational current Device (AC-53) Assigned motor rating (Standard connection, In-Line) at 230 V, 50 Hz P kW 7.5 18.5 30 37 55 75 90 110 132 at 400 V, 50 Hz P kW 18.5 30 55 75 90 132 160 200 200 at 500 V, 50 Hz P kW 22 45 55 90 110 160 200 250 250 at 690 V, 50 Hz P kW - - - - 160 200 250 - - at 200 V, 60 Hz P HP 10 20 30 40 60 75 100 125 125 at 230 V, 60 Hz P HP 10 20 40 50 60 75 100 150 150 at 480 V, 60 Hz P HP 25 50 75 100 150 200 250 300 350 at 600 V, 60 Hz P HP 30 60 100 125 150 200 300 350 450 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1 x (70 - 240) 1 x (70 - 240) 2 x (25 - 240) 2 x (25 - 240) 1 x (70 - 240) 1 x (70 - 240) 2 x (25 - 240) 2 x (25 - 240) 1 x (70 - 240) 1 x (70 - 240) 2 x (25 - 240) 2 x (25 - 240) 1 x (4 - 500 kcmil) 1 x (4 - 500 kcmil) 2 x (4 - 500 kcmil) 2 x (4 - 500 kcmil) 25.5 (≤ 150 mm²); 25.5 (≤ 150 mm²); 28.3 (> 150 mm²) 28.3 (> 150 mm²) 4 mm Hexagon socket-head screw 1 x (70 - 240) 2 x (25 - 240) 1 x (70 - 240) 2 x (25 - 240) 1 x (70 - 240) 2 x (25 - 240) 1 x (4 - 500 kcmil) 2 x (4 - 500 kcmil) 25.5 (≤ 150 mm²); 28.3 (> 150 mm²) 1 x (70 - 240) 2 x (25 - 240) 1 x (70 - 240) 2 x (25 - 240) 1 x (70 - 150) 2 x (25 - 240) 1 x (4 - 500 kcmil) 2 x (4 - 500 kcmil) - 1 x (70 - 240) 2 x (25 - 240) 1 x (70 - 240) 2 x (25 - 240) 1 x (70 - 150) 2 x (25 - 240) 1 x (4 - 500 kcmil) 2 x (4 - 500 kcmil) - - - Internal bypass contacts Terminal capacities Cable lengths Solid mm2 1 x (2.5 - 35) 1 x (2.5 - 35) 1 x (2.5 - 95) 1 x (2.5 - 95) Flexible with ferrule mm2 1 x (2.5 - 35) 1 x (2.5 - 35) 1 x (2.5 - 95) 1 x (2.5 - 95) Stranded mm2 1 x (2.5 - 35) 1 x (2.5 - 35) 1 x (2.5 - 95) 1 x (2.5 - 95) Solid or stranded AWG 1 x (14 - 2) 1 x (14 - 2) 1 x (14 - 4/0) 1 x (14 - 4/0) Tightening torque Nm 4 (≤ 6 mm²); 4.5 (≤ 10 mm²); 5 (≤ 25 mm²); 5.6 (> 25 mm²) 11.3 11.3 Screwdriver (PZ: Pozidriv) mm 1,5 x 6 mm 4 mm Hexagon sockethead screw 4 mm Hexagon sockethead screw CA04020001Z-EN-INT www.eaton.eu 1,5 x 6 mm CA04020001Z-EN-INT www.eaton.eu 144 Soft starter S801+, S811+ Soft starter S801+, S811+ Basic devices 145 Basic devices S8x1+N37… S8x1+N66… S8x1+R10… S8x1+R13… S8x1+T18… S8x1+T24… S8x1+T30… S8x1+U36… S8x1+U42… 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 3 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 5 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 7 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 9 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 12 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 15 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 18 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 21 x (12 - 14) 2 x (12 - 14) 0.4 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 Control cables Solid mm2 Flexible with ferrule mm2 Stranded mm2 Solid or stranded AWG Tightening torque Nm 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (12 - 14) 2 x (12 - 14) 0.4 Screwdriver mm 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 Control circuit Regulator supply Notes External supply voltage Voltage Us V 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % Current consumption Ie mA 1000 1000 1000 1000 1000 1000 1000 1000 1000 IPeak mA/ms 10.000 / 15 10.000 / 15 10.000 / 15 10.000 / 15 10.000 / 15 10.000 / 15 10.000 / 15 10.000 / 15 10.000 / 15 V DC 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % mA 100 100 100 100 100 100 100 100 100 V DC 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 V DC 3 3 3 3 3 3 3 3 3 ms 100 100 100 100 100 100 100 100 100 ms 100 100 100 100 100 100 100 100 100 Current consumption at peak performance (close bypass) at 24 V DC Digital inputs Control voltage DC-operated Current consumption 24 V External 24 V (no-load) Pick-up voltage DC-operated Drop-out voltage DC operated Pick-up time DC operated DC operated S801+, S811+ Drop-out time Relay outputs Number 2 2 2 2 2 2 2 2 2 Voltage range V AC 120 V AC/DC 120 V AC/DC 120 V AC/DC 120 V AC/DC 120 V AC/DC 120 V AC/DC 120 V AC/DC 120 V AC/DC 120 V AC/DC AC-11 current range A 3 A, AC-11 3 A, AC-11 3 A, AC-11 3 A, AC-11 3 A, AC-11 3 A, AC-11 3 A, AC-11 3 A, AC-11 3 A, AC-11 Acceleration s 180 180 180 180 180 180 180 180 180 Deceleration s 0 - 60 0 - 60 0 - 60 0 - 60 0 - 60 0 - 60 0 - 60 0 - 60 0 - 60 % 85 85 85 85 85 85 85 85 85 % 100 100 100 100 100 100 100 100 100 50 Hz ms 2000 2000 2000 2000 2000 2000 2000 2000 2000 60 Hz ms 2000 2000 2000 2000 2000 2000 2000 2000 2000 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Soft start function Ramp times Start pedestal Kickstart Voltage Duration Fields of application Fields of application Soft starting of three-phase asynchronous motors 3-phase motors ✓ ✓ Soft starting of three-phase asynchronous motors ✓ Functions Fast switching (semiconductor contactor) Soft start function - (minimum ramp time 1s) Reversing starter External solution required (reversing contactor) Suppression of closing transients ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Current limitation ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Overload monitoring ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Underload monitoring ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 10 10 10 10 10 10 10 10 10 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Modbus RTU Modbus RTU Modbus RTU Modbus RTU Modbus RTU Modbus RTU Modbus RTU Modbus RTU Modbus RTU Fault memory Faults Suppression of DC components for motors Potential isolation between power and control sections Built-in interfaces CA04020001Z-EN-INT ✓ www.eaton.eu - (minimum ramp time 1s) ✓ ✓ ✓ ✓ External solution required (reversing contactor) CA04020001Z-EN-INT www.eaton.eu 146 Soft starter S801+, S811+ Soft starter S801+, S811+ Basic devices 147 Basic devices S8x1+V36… S8x1+V42… S8x1+V50… S8x1+V65… S8x1+V72… S8x1+V85… S8x1+V10… IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 CE IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 CE IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 CE IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 CE IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 CE IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 CE IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 CE UL UL CSA CSA C-Tick C-Tick CCC CCC Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 UL CSA C-Tick CCC UL CSA C-Tick CCC UL UL CSA CSA C-Tick C-Tick CCC CCC Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 UL CSA C-Tick CCC General Standards Approvals Approvals Climatic proofing Ambient temperature Operation ϑ °C -30 - +50 -30 - +50 -30 - +50 -30 - +50 -30 - +50 -30 - +50 -30 - +50 Storage ϑ °C -50 - +70 -50 - +70 -50 - +70 -50 - +70 -50 - +70 -50 - +70 -50 - +70 m 0 - 2000 m, above that each 100 m 0.5% Derating Altitude Mounting position 0 - 2000 m, above that each 100 m 0.5% Derating As required As required As required As required As required As required As required Protection type IP20 (terminals IP00) IP20 (terminals IP00) IP20 (terminals IP00) IP20 (terminals IP00) IP20 (terminals IP00) IP20 (terminals IP00) IP20 (terminals IP00) Integrated Protection type IP40 can be achieved on all sides with covers SS-IP20-N. Degree of protection Protection type IP40 can be achieved on all sides with covers SS-IP20-N. Protection against direct contact Finger- and back-of-hand proof Overvoltage category/pollution degree Shock resistance II/3 II/3 II/3 II/3 Finger- and back-of-hand proof II/3 II/3 II/3 15 g 15 g 15 g 15 g 15 g 15 g 15 g Radio interference level (IEC/EN 55011) Heat dissipation A A A A A A A W 25 25 25 25 25 25 25 Weight kg 41.4 41.4 41.4 41.4 41.4 41.4 41.4 V AC 200 - 600 200 - 600 200 - 600 200 - 600 200 - 600 200 - 600 200 - 600 200 - 690 200 - 690 200 - 690 200 - 690 200 - 690 200 - 690 - Rated operating voltage Ue …V3S Supply frequency fLN Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Ie A 361 420 500 650 720 850 1000 S801+, S811+ Main conducting paths Rated operational current Device (AC-53) Assigned motor rating (Standard connection, In-Line) at 230 V, 50 Hz P kW 110 132 160 200 200 200 200 at 400 V, 50 Hz P kW 200 200 250 315 400 450 560 at 500 V, 50 Hz P kW 250 250 315 450 500 560 630 at 690 V, 50 Hz P kW 315 400 500 630 630 710 - at 200 V, 60 Hz P HP 125 150 150 200 200 200 200 at 230 V, 60 Hz P HP 150 150 200 250 250 350 400 at 480 V, 60 Hz P HP 300 350 400 500 600 600 750 at 600 V, 60 Hz P HP 350 450 500 600 750 850 850 ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (4 - 500 kcmil) 4 x (4 - 500 kcmil) 6 x (4 - 500 kcmil) - 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (4 - 500 kcmil) 4 x (4 - 500 kcmil) 6 x (4 - 500 kcmil) - 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (4 - 500 kcmil) 4 x (4 - 500 kcmil) 6 x (4 - 500 kcmil) - 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (4 - 500 kcmil) 4 x (4 - 500 kcmil) 6 x (4 - 500 kcmil) - 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (4 - 500 kcmil) 4 x (4 - 500 kcmil) 6 x (4 - 500 kcmil) - 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (4 - 500 kcmil) 4 x (4 - 500 kcmil) 6 x (4 - 500 kcmil) - - - - - - - Internal bypass contacts Terminal capacities Cable lengths Solid mm2 Flexible with ferrule mm2 Stranded mm2 Solid or stranded AWG Tightening torque Nm 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (120 - 240) 4 x (70 - 240) 6 x (120 - 240) 2 x (4 - 500 kcmil) 4 x (4 - 500 kcmil) 6 x (4 - 500 kcmil) - Screwdriver (PZ: Pozidriv) mm - CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 148 Soft starter S801+, S811+ Soft starter S801+, S811+ Basic devices 149 Basic devices S8x1+V36… S8x1+V42… S8x1+V50… S8x1+V65… S8x1+V72… S8x1+V85… S8x1+V10… 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 30 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 33 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 36 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 39 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 42 x (12 - 14) 2 x (12 - 14) 0.4 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 45 x (12 - 14) 2 x (12 - 14) 0.4 Control cables Solid mm2 Flexible with ferrule mm2 Stranded mm2 Solid or stranded AWG Tightening torque Nm 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 1 x (2.5 - 4) 2 x (1.0 - 2.5) 27 x (12 - 14) 2 x (12 - 14) 0.4 Screwdriver mm 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 0,6 x 3,5 Control circuit Regulator supply Notes External supply voltage Voltage Us V 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % Current consumption Ie mA 1400 1400 1400 1400 1400 1400 1400 IPeak mA/ms 10.000 / 15 10.000 / 15 10.000 / 15 10.000 / 15 10.000 / 15 10.000 / 15 10.000 / 15 V DC 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % 24 V DC +10 %/- 10 % mA 100 100 100 100 100 100 100 V DC 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 V DC 3 3 3 3 3 3 3 ms 100 100 100 100 100 100 100 ms 100 100 100 100 100 100 100 Current consumption at peak performance (close bypass) at 24 V DC Digital inputs Control voltage DC-operated Current consumption 24 V External 24 V (no-load) Pick-up voltage DC-operated Drop-out voltage DC operated Pick-up time DC operated DC operated S801+, S811+ Drop-out time Relay outputs 2 2 2 2 2 2 2 Voltage range Number V AC 120 V AC/DC 120 V AC/DC 120 V AC/DC 120 V AC/DC 120 V AC/DC 120 V AC/DC 120 V AC/DC AC-11 current range A 3 A, AC-11 3 A, AC-11 3 A, AC-11 3 A, AC-11 3 A, AC-11 3 A, AC-11 3 A, AC-11 Acceleration s 180 180 180 180 180 180 180 Deceleration s 0 - 60 0 - 60 0 - 60 0 - 60 0 - 60 0 - 60 0 - 60 % 85 85 85 85 85 85 85 % 100 100 100 100 100 100 100 50 Hz ms 2000 2000 2000 2000 2000 2000 2000 60 Hz ms 2000 2000 2000 2000 2000 2000 2000 ✓ ✓ Soft start function Ramp times Start pedestal Kickstart Voltage Duration Fields of application Fields of application Soft starting of three-phase asynchronous motors 3-phase motors ✓ ✓ Soft starting of three-phase asynchronous motors ✓ ✓ ✓ ✓ ✓ Functions Fast switching (semiconductor contactor) Soft start function - (minimum ramp time 1s) Reversing starter External solution required (reversing contactor) Suppression of closing transients ✓ ✓ ✓ ✓ ✓ ✓ ✓ Current limitation ✓ ✓ ✓ ✓ ✓ ✓ ✓ Overload monitoring ✓ ✓ ✓ ✓ ✓ ✓ ✓ Underload monitoring ✓ ✓ ✓ ✓ ✓ ✓ ✓ 10 10 10 10 10 10 10 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Modbus RTU Modbus RTU Modbus RTU Modbus RTU Modbus RTU Modbus RTU Modbus RTU Fault memory Faults Suppression of DC components for motors Potential isolation between power and control sections Built-in interfaces CA04020001Z-EN-INT ✓ www.eaton.eu - (minimum ramp time 1s) ✓ ✓ ✓ ✓ External solution required (reversing contactor) CA04020001Z-EN-INT www.eaton.eu 150 Soft starter S801+, S811+ Basic devices Dimensions Basic devices 174.5 mm (6.87") 187 mm (7.36") S8x1+N… 165 mm (6.50") 50 mm (1.97") 67.5 mm (2.66") 201 mm (7.91") 189 mm (7.44") S8x1+R… 90 mm (3.54") 170 mm (6.69") 111 mm (4.37") 299 mm (11.77") 323 mm (12.72") S8x1+T… 75 mm 75 mm (2.95") (2.95") 196 mm (7.72") CA04020001Z-EN-INT www.eaton.eu 164 mm (6.46") Soft starter S801+, S811+ 151 Basic devices 299 mm (11.77") 323 mm (12.72") S8x1+U… 182 mm (7.16") 66.4 mm 66.4 mm (2.6") (2.6") 196 mm (7.72") 95 mm (3.74") S801+, S811+ 421 mm (16.57") 385 mm (15.16") S8x1+V… 188 mm (7.40") 281 mm (11.06") CA04020001Z-EN-INT www.eaton.eu Rapid Link 4.0 distributed, electronic drive system Standardized installation procedures, the ability to directly and locally configure parameters with a plug and play configuration, and networked communications – these are the needs of material handling system applications today when it comes to state-of-theart drive engineering and the systems it produces. Eaton delivers a modern answer with the Rapid Link 4.0 distributed electronic drive system. With its flexible power spectrum, its simple handling and its intelligent programming options, this new motor starter and variable frequency drives generation is the first choice for all kinds of conveying engineering applications. RAMO electronic motor starters Electronic DOL and reversing starters with a lifespan of more than 10 million switching operations, IP 65 degree of protection. Rated adjustable operational current of 0.3 – 6.6 A with threephase mains connection of 400 V; allocated motor output of 0.09 – 3.0 kW RAMO-D…: DOL starter RAMO-W…: reversing starter RASP speed controllers Frequency-controlled motor starters with Volts-per-Hertz control (V/Hz control) and slip compensation or voltage-controlled vector control, as well as an integrated radio interference suppression filter (EMC), IP65 degree of protection. RASP-2…: Rated operational current of 0.48 – 2.4 A with three-phase mains connection of 400 V; assigned motor output of up to 0.75 kW RASP-3…: Rated operational current of 0.66 – 3.3 A with three-phase mains connection of 400 V; assigned motor output of up to 1.1 kW RASP-4…: Rated operational current of 0.86 – 4.3 A with three-phase mains connection of 400 V; assigned motor output of up to 1.5 kW RASP-5…: Rated operational current of 1.12 – 5.6 A with three-phase mains connection of 400 V; allocated motor output of up to 2.2 kW Rapid Link 4.0 System overview 153 154 Description Application and function 156 Key to type references 157 Ordering Motor starter RAMO 158 RASP speed controllers 159 Accessories 160 Engineering General information on Engineering 164 Block diagram RAMO-D DOL starter 166 Block diagram RAMO-W reversing starter 168 Block diagram RASP 170 Technical data Motor starter RAMO 172 RASP speed controllers 172 Accessories 174 Dimensions 175 RASP speed controllers 176 Accessories 177 Rapid Link Motor starter RAMO CA04020001Z-EN-INT www.eaton.eu 154 Rapid Link 4.0 Rapid Link 4.0 System overview Rapid Link 4.0 1 2 3 4 7 3 AC, (N), PE 50/60 Hz 5 12 10 8 10 6 9 11 M 3 12 13 M 3 14 16 15 18 19 20 CA04020001Z-EN-INT www.eaton.eu 21 22 17 11 Rapid Link 4.0 155 Rapid Link 4.0 Function modules Motor starter (Motor Control Unit) Motor feeder 1 Three-phase electronic DOL starter or reversing starter → page 158 Speed controller RASP (Speed Control Unit) Unscreened motor cable Power and data bus 5 → page 160 Screened motor supply cable (EMC) 2 Three phase frequency-controlled motor starter (fixed speeds, two rotational directions, adjustable acceleration and deceleration ramps) → page 159 6 Energy supply (3 AC 400 V) via circuitbreaker for overload and short-circuit protection 7 for protection against short-circuit and overload → page 160 AS-Interface® feeder unit 8 AS-Interface® flat cable 9 AS-Interface® connection cable 10 → page 163 3 AS-Interface® junction Fan for operation at high temperatures without derating → page 160 11 → page 163 4 12 Sensor connection → page 163 End-piece for flat cable 13 → page 162 14 distributor module for 400-V-AC incoming unit of the flat cable → page 161 Power connection cable 15 to flexible busbar junction → page 160 flexible busbar junction 16 → page 161 Ribbon cable for 400 V AC 17 → page 160 Power connection cable 18 to round cable junction → page 162 Round cable junction 19 → page 162 Round cable for 400 V AC 20 Power connection cable 21 to round cable junction → page 162 Round cable junction 22 → page 162 CA04020001Z-EN-INT www.eaton.eu Rapid Link operating unit for parameter setting → page 160 156 Rapid Link 4.0 System System Rapid Link 4.0 is a modern, efficient drive and PLC. It is the competent further development of the Rapid Link 2.1/3.0 device series, suitable for simple and complex tasks in all aspects of material handling. For example in airports, industrial production and logistics centers. The Rapid Link system consists of the RAMO electronic motor starters and the RASP frequency controlled motor starters. The RAMO and RASP motor starters are designed with IP65 protection and can be installed in direct proximity to the drive. Their versions and mounting depend on the required specifications and the local conditions. The RAMO and RASP are connected with standard plug connectors to the energy and databus systems predominantly used in material handling systems (AS-Interface). Connection can be implemented without interrupting the required location. This simplifies installation and reduces the wiring requirement. Overview of features RAMO 4.0 electronic motor starters Frequency controlled motor starter RASP 4.0 Application and function The RAMO motor starters enable the electronic DOL or reversing starting of three-phase motors in automatic or manual mode. The electronic overload protection for motor ratings from 90 W to 3 kW at 400 V (50/60 Hz) is configured with DIP switches. Full motor protection is ensured when used in connection with temperature sensors. The operating mode is set via the AUTO - OFF/RESET – MANUAL key switch and can be combined with the 'Quick stop' and 'Interlocked manual operation' via the two sensor inputs (M12 sockets). Operating states are diagnosed and error messages (Reset) acknowledged on the device or via the AS-Interface. RAMO is available in different versions: • with actuator output (24 V DC) for a direct actuation of external switching devices, e.g. solenoid valves. • with electronic actuation for mechanical motor brakes. • with lockable repair switch for diagnostic and maintenance work, making it possible to safely de-energize the device locally. Application and function The RASP motor starter enables the infinitely variable speed control of three-phase motors in the range from zero to 320 Hz . The standard size for 400 V (50/60 Hz) is assigned four motor ratings: 0.75 kW, 1.1 kW, 1.5 kW and 2.2 kW. Full motor protection is ensured by the adjustable current limitation (I2t controller). The operating mode is set via the AUTO - OFF/RESET – MANUAL key switch and can be combined with the 'Quick stop' and 'Interlocked manual operation' via the two sensor inputs (M12 sockets). Settable fixed frequencies and cyclical program sequences extend the application range and relieve the load on the higher-level head-end controller (PLC). Operating states are diagnosed and error messages (Reset) acknowledged on the device or via the ASInterface. A hand-held programmer and a PC interface are available for the parameterization of the variable frequency drive module. RASP is available in different versions: • with integrated brake chopper with braking resistance for dynamic braking. • with electronic actuation for mechanical motor brakes. • with lockable repair switch for diagnostic and maintenance work, making it possible to safely de-energize the device locally. Essential features • Standard size in square enclosure. The bottom section with the two power terminals (power plug, motor feeder socket) and the repair and maintenance switch can be turned 90° clockwise and counterclockwise. • Long lifespan up to 10 million switching operations and up to 3,000 switch cycles per hour at 2.2 kW. • Rated operational current 6.6 A. • Operating and ambient temperature from -10 to +55 °C, without derating. • Monitoring of thermistor and motor cable. • Maximum motor cable length: 10 m. CA04020001Z-EN-INT www.eaton.eu Essential features • Standard size in square enclosure. The bottom section with the two power terminals (power plug, motor feeder socket) and the repair and maintenance switch can be turned 90° clockwise and counterclockwise. • Monitoring of thermistor and motor cable. • Operating and ambient temperatures from 0 to +40 °C without derating, with optional fan in the performance range up to 1.5 kW max. +55 °C. • Rated operational current: 2.4 A, 3.3 A, 4.3 A, 5.6 A • EMC class C3 in 2nd environment • Maximum motor cable length: 5 m. Rapid Link 4.0 157 Key to type references Electronic motor starters RAMO Key to type references RAMO - D A 2 AI1 S - C32 R S1 Type Version RAMO S1 = Standard Starters Option D = DOL starter W = Reversing starter 0 = no option R = manual override switch Output Power connections 0 = no output A = Actuator output C32 = pluggable at bottom Ambient temperature during operation Breaking resistance 0 = no breaking voltage 2 = 230 V AC 4 = 400 V AC S = Standard (-10 - 55 °C) AS-Interface® AI1 = S-7.4 AI2 = S-7.A.E. Frequency controlled motor starter RASP R S1 Type Version RAMO S1 = Standard Starters Option D = DOL starter W = Reversing starter 0 = no option R = manual override switch Output Power connections 0 = no output A = Actuator output C32 = pluggable at bottom Breaking resistance 0 = no breaking voltage 2 = 230 V AC 4 = 400 V AC Rapid Link RAMO - D A 2 AI1 S - C32 Ambient temperature during operation S = Standard (-10 - 55 °C) AS-Interface® AI1 = S-7.4 AI2 = S-7.A.E. CA04020001Z-EN-INT www.eaton.eu 158 Rapid Link 4.0 Motor starter RAMO Ordering Rated operational current Ie Control voltage external brake (50/60 Hz)1) Actuator output2) A V AC Number S-7.4 for 31 modules S-7.A.E. for 62 modules Motor starter RAMO AS-Interface profile cable 6.6 - - ✓ - 6.6 230 - ✓ - 6.6 230 - - ✓ 6.6 230 1 ✓ - 6.6 400 - ✓ - 6.6 400 - - ✓ 6.6 400 1 ✓ - 6.6 - - ✓ - 6.6 230 - ✓ - 6.6 230 - - ✓ 6.6 400 - ✓ - 6.6 400 - - ✓ - - ✓ - 6.6 230 - ✓ - 6.6 230 - - ✓ 6.6 230 1 ✓ - 6.6 400 - ✓ - 6.6 400 - - ✓ 6.6 400 1 ✓ - 6.6 - - ✓ - 6.6 230 - ✓ - 6.6 230 - - ✓ 6.6 400 - ✓ - 6.6 400 - - ✓ Part no. Article no. Price see price list Std. pack Motor starter RAMO Rated operational voltage 400 V AC DOL starters RAMO-D00AI1S-C320S1 150150 RAMO-D02AI1S-C320S1 150152 RAMO-D02AI2S-C320S1 171776 RAMO-DA2AI1S-C320S1 164321 RAMO-D04AI1S-C320S1 169799 RAMO-D04AI2S-C320S1 171778 RAMO-DA4AI1S-C320S1 169800 1 off RAMO-D00AI1S-C32RS1 150158 RAMO-D02AI1S-C32RS1 150160 RAMO-D02AI2S-C32RS1 171782 RAMO-D04AI1S-C32RS1 169801 RAMO-D04AI2S-C32RS1 171784 1 off RAMO-W00AI1S-C320S1 150151 RAMO-W02AI1S-C320S1 150153 RAMO-W02AI2S-C320S1 171777 RAMO-WA2AI1S-C320S1 164322 RAMO-W04AI1S-C320S1 169802 RAMO-W04AI2S-C320S1 171779 RAMO-WA4AI1S-C320S1 169803 1 off RAMO-W00AI1S-C32RS1 150159 RAMO-W02AI1S-C32RS1 150161 RAMO-W02AI2S-C32RS1 171783 RAMO-W04AI1S-C32RS1 169804 RAMO-W04AI2S-C32RS1 171785 1 off with manual override switch Reversing starter with selector switch REV - OFF - FWD 6.6 with manual override switch Instructions 1) for actuation of motors with mechanical brake with external 24V DC supply 2) Operation CA04020001Z-EN-INT www.eaton.eu Rapid Link 4.0 159 RASP speed controllers RASP speed controllers Rated operatio nal current1) assigned motor rating P2) Control voltage external brake (50/60 Hz)3) with braking resistance4) Part no. Article no. Price see price list Part no. Article no. Price see price list Std. pack at 400 V, 50 Hz Ie P A A V AC RASP speed controllers Rated operational voltage 400 V AC AS-Interface profile cable S-7.4 for 31 modules 2.4 - - 2.4 - 230 2.4 - 400 3.3 - - 3.3 - 230 3.3 - 400 4.3 - - 4.3 - 230 4.3 - 400 5.6 - - 5.6 - 230 5.6 - 400 2.4 - - 2.4 - 230 2.4 - 400 3.3 - - 3.3 - 230 3.3 - 400 4.3 - - 4.3 - 230 4.3 - 400 5.6 - - 5.6 - 230 5.6 - 400 RASP-200AI1S0-C320S1 150168 RASP-202AI1S0-C320S1 150176 RASP-204AI1S0-C320S1 169805 RASP-300AI1S0-C320S1 150169 RASP-302AI1S0-C320S1 150177 RASP-304AI1S0-C320S1 169806 RASP-400AI1S0-C320S1 150170 RASP-402AI1S0-C320S1 150178 RASP-404AI1S0-C320S1 169807 RASP-500AI1SL-C320S1 150171 RASP-502AI1SL-C320S1 150179 RASP-504AI1SL-C320S1 169808 RASP-210AI1S0-C320S1 150172 RASP-212AI1S0-C320S1 150180 RASP-214AI1S0-C320S1 169809 RASP-310AI1S0-C320S1 150173 RASP-312AI1S0-C320S1 150181 RASP-314AI1S0-C320S1 169810 RASP-410AI1S0-C320S1 150174 RASP-412AI1S0-C320S1 150182 RASP-414AI1S0-C320S1 169811 RASP-510AI1SL-C320S1 150175 RASP-512AI1SL-C320S1 150183 RASP-514AI1SL-C320S1 169812 1 off RASP-200AI1S0-C32RS1 150200 RASP-202AI1S0-C32RS1 150208 RASP-204AI1S0-C32RS1 169813 RASP-300AI1S0-C32RS1 150201 RASP-302AI1S0-C32RS1 150209 RASP-304AI1S0-C32RS1 169814 RASP-400AI1S0-C32RS1 150202 RASP-402AI1S0-C32RS1 150210 RASP-404AI1S0-C32RS1 169815 RASP-500AI1SL-C32RS1 150203 RASP-502AI1SL-C32RS1 150211 RASP-504AI1SL-C32RS1 169816 RASP-210AI1S0-C32RS1 150204 RASP-212AI1S0-C32RS1 150212 RASP-214AI1S0-C32RS1 169817 RASP-310AI1S0-C32RS1 150205 RASP-312AI1S0-C32RS1 150213 RASP-314AI1S0-C32RS1 169818 RASP-410AI1S0-C32RS1 150206 RASP-412AI1S0-C32RS1 150214 RASP-414AI1S0-C32RS1 169819 RASP-510AI1SL-C32RS1 150207 RASP-512AI1SL-C32RS1 150215 RASP-514AI1SL-C32RS1 169820 1 off Instructions Rapid Link with manual override switch 1) for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz 2) Rated operational current at an operating frequency of 6 kHz and an ambient air temperature of +40 °C 3) for actuation of motors with mechanical brake 4) integrated brake chopper with braking resistance for dynamic braking CA04020001Z-EN-INT www.eaton.eu 160 Rapid Link 4.0 Accessories Accessories Std. pack Instructions RASP-KEY-S1 156644 1 off - RASP XMX-CBL-3M4-USB 153448 1 off - RASP RASP-FAN-S1 156643 1 off - Length m 2 RAMO 1 off - 5 RAMO 1 off - 10 RAMO RAMO-CM1-2M0 164282 RAMO-CM1-5M0 164283 RAMO-CM1-10M 164284 1 off - 2 RASP 1 off - 5 RASP RASP-CM1-2M0 164285 RASP-CM1-5M0 164286 1 off - RAMO-CM1… RASP-CM1… SET-M-LOCK 272085 1 off For padlocks with hasp thickness up to 8 mm RA-C1… RA-C1-7X4HF 230860 100 runn. m Paint film contaminant/ silicon-free RAMO RASP RA-C1-PLF RA-C3/C1-1,5HF 290210 1 off - Description For use with Part no. Article no. RASP Price see price list Communications Operating unit for setting the device parameters with non-volatile parameter memory for copying parameter sets Equipment supplied: including 1 m connection cable with RJ45 connectors BACK RESET OK LOC REM I Programming cable for connecting the device to the PC USB For configuring the device's parameters with the MaxConnect computer program RJ 45 with RJ 45 plug and USB plug Length 3.4 m Device fans RASP device fan for operation at high temperatures without derating Power supply and control via RASP through M12 plug connector Enhanced cooling for ambient temperatures of up to +55 °C for RASP-2…, RASP-3…., and RASP-4... Spare part for RASP-5... Motor feeder Motor cable for connecting the motor starter to the motor halogen free, 8 x 1.5 mm2, plastic plug halogen free, screened, 4 x 1.5 mm2 + 2 x (2 x 0.75 mm2), plastic plug Locking brackets for the safe isolation of the motor cables from power For motor cables and motor plugs, disconnection device to EN 60204-1 Power supply at flat cable RA-C1 Flat cable for 400 V AC/24 V DC decentralized power supply or AS-Interface halogen free, 7 x 4 mm2 Power connection cable for connecting the device with the 400 V AC flexible busbar junction with power plug and plug for flexible busbar junction, halogen-free, 5 x 1.5 mm2 CA04020001Z-EN-INT www.eaton.eu Rapid Link 4.0 161 Accessories For use with Part no. Article no. Flexible busbar junction 400 V AC/24 V DC Connection socket for power connection cable Insulation piercing terminals, terminal socket with lock mechanism RA-C1-7X4HF RA-C3/C1-1,5HF Protection cover for protecting the 400 V AC/24 V DC flexible busbar junction - Description Price see price list Std. pack Instructions RA-C1-PLF 290188 5 off - RA-C1-PLF RA-C1-COV 254693 10 off - RA-C1-PLF RA-C1-VP-PLM 231574 5 off Order cable gland V-M25 separately. RA-C1-AM-7 290214 5 off Order cable gland V-M25 or V-M20 separately. RA-C1-PLM/C3-1M5 112624 1 off Can be used when AS‐Interface implemented in flat cable. RA-C1-PLF1 116904 1 off Can be used when AS‐Interface implemented in flat cable. RA-C1-AM/C3-1M5 112625 1 off Can be used when AS‐Interface implemented in flat cable. RA-C1-VM-7 264244 2 off Order V-M25/V-M20 cable gland and RA-C1-DF bushing separately. RA-C1-VM-7 RA-C1-DF 264243 10 off - RA-C1-7X4HF RA-C1-VP-AM-2 264315 5 off Order cable gland V-M20 separately RA-C1-7X4HF RA-C1-FIX 272086 100 off One set with 100 clips. Power supply at flat cable RA-C1 Plug insert with hood Distributor module for feeding the 400-V-AC/24-V-DC of the ribbon cable with a round cable Termination with piercing screws, RA-C1-7X4HF 2 x V-M25 and 2 x V-M20 knockout plates, connection module with springloaded terminals, connection of round cables up to 4 mm2. Power/AS-Interface connection cable for connecting the device with the 400 V AC AS-Interface flexible busbar junction Double cable with outgoer plug (flexible RAMO busbar end) and M12 plug and power RASP plug (device end) RA-C1-PLF1 400 V AC/AS-Interface flexible busbar junction Connection socket for power/AS-Interface cable Insulation piercing terminals, terminal socket with lock mechanism RA-C1-7X4HF RA-C1-PLM/C31M5 Power/AS-Interface connection cable For connecting the device with 400 V AC/24 V DC/AS-Interface flexible busbar Double cable with connection module RAMO (flexible busbar end) and M12 plug as RASP well as power plug (device end), RA-C1-7X4HF termination with piercing screws, knockouts Length 1.5 m Distributor module for the 400V AC feeding to the ribbon cable with a round cable With 3 flexible busbar inputs and 2 round RA-C1-7X4HF cable inputs Connection of round cables 4 mm2 Flexible busbar bushing for bushing for flat cable in distributor module or control cabinet - Distributor module 24 V DC control voltage is taken from the ribbon cable Termination with piercing screws, connection sockets with screw contacts Flexible busbars for fastening the ribbon cable - CA04020001Z-EN-INT www.eaton.eu Rapid Link Plug connector for 400 V AC/24 V DC flexible busbar junction 162 Rapid Link 4.0 Accessories For use with Part no. Article no. RA-C1-7X4HF For cutting flat cable for removing casing at the ends of the flat cable Description Length Price see price list Std. pack Instructions RA-C1-END1 290189 10 off - RA-C1-7X4HF RA-C1-CUT 254690 1 off - RA-C1-7X4HF RA-C1-AZ-4 272087 1 off A standard engineer's pliers is required. RAMO RASP RA-C2-S1-4 RA-C3/C2-1,5HF 290211 1 off - RA-C3/C2-1,5HF RA-C2-S1-4 257830 1 off Equipment supplied: 1 pairs of gaskets for these cable diameters, 1 lock mechanism. RA-C2-S1-4 RA-C2-SBL 265357 10 off One set with 10 blanking plugs. RA-C4-PPB/ C3-1M5 RA-C4-X/ C3-1M5 RA-C4-PB65 116905 1 off Tools required: Stripping tool AM16 from Weidmüller or similar. Enclosure continuous seals must be ordered separately. RA-C4-PB65 RA-C4-D13 116907 RA-C4-D15 116908 RA-C4-D17 116909 10 off - 10 off - 10 off - RA-C4-PB65 RA-C4-D0 116960 10 off One set with 10 blanking plugs. RAMO RASP RA-C4-PB65 RA-C4-PPB/C3-1M5 116962 1 off - m Power supply at flat cable RA-C1 End-piece for terminating the ribbon cable - Tools Power supply at round cable RA-C2 Power connection cable for connecting the device with the round cable junction with power plug and plug for round cable junction, halogen-free, 5 x 1.5 mm2 1.5 Round cable junction Connection socket for power connection cable for 7 x 2.5/4 mm2, 400 V AC and 24 V DC, termination with insulation piercing technology, cable fixing with metal screws, pre-wired socket insert, suitable for cable outer diameters 10 - 13 mm. Blanking plug for closing the last round cable junction in the power line - Power supply at round cable RA-C4 Round cable junction Connection socket for power cables from 2.5 - 6 mm2 T junction via spring-cage terminal, 1.5 to 6 mm2 and/or plug connection of 0.5 - 4 mm2, Enclosure IP65 Gasket Slotted enclosure bushing seal for Ø 11 - 13 mm EPDM round cable, silicon free and halogen free, IP65 for Ø 13 - 15 mm EPDM round cable, silicon free and halogen free, IP65 for Ø 15 - 17 mm EPDM round cable, silicon free and halogen free, IP65 RA-C4-PB65 RA-C4-PB65 Blanking plug for closing off unused housing openings Enclosure seal, closed, EPDM, silicon free and halogen free, IP65 Power connection cable for connecting the device with the round cable junction Cable 5 x 1.5 mm2, halogen-free, with RA-C4-PPB plug for round cable junction, power plug and gasket IP65 CA04020001Z-EN-INT www.eaton.eu 1.5 Rapid Link 4.0 163 Accessories Description Std. pack Instructions RA-C4-X/C3-1M5 116961 1 off - RA-C4-PB65 RA-C4-PPB 116906 10 off - RA-C1-AM-7 RA-C1-AM/C31M5 RA-C1-VP-AM-2 RA-C1-AZPG 112978 1 off - RAMO RASP ZB2-100-AZ1 082667 1 off - 1 RASP RASP RA-XAZ2-1M 292253 1 off - 1 RAMO RASP RA-XM12-1M 272057 1 off Pins 1, 3, 4 are assigned RASP RA-XM12-Y 290424 1 off - RAMO RASP M22-ES-MS1 216416 5 off - Length For use with Part no. Article no. RAMO RASP RA-C4-PB65 Price see price list m Power connection cable for user assembly for connecting the device with the round cable junction Cable 5 x 1.5 mm2 halogen free, with ferrules, power plug and IP65 gasket 1.5 Plug connectors for wiring the power connection cable for user assembly Plug with spring-cage terminal 0.5 - 4 mm2, printed with 1; N; 2; PE; 3. Connection clip for AS-Interface flat cable to AS-Interface incomer/outgoer for connection modules with integrated AS‐Interface overvoltage protection, protection against interference on switch operations or short-circuit, cable termination with insulation displacement AS-Interface link M12 connection socket for AS-Interface connection cable IDC termination 24V/AS-Interface connection cable for supplying the device with 24 V/AS-Interface with M12 socket and double outgoer for AS-Interface and 24 V, cable termination with insulation displacement AS-Interface connection cable for connecting the device with AS-Interface junction with M12 socket and M12 plug, 3-pole Y connector For connecting up to 2 sensors per M12 socket - Rapid Link AS-Interface connection and sensors AS-Interface connection and sensors Spare keys for AUTO - OFF/RESET - HAND key-switches Lock mechanism MS1 CA04020001Z-EN-INT www.eaton.eu 164 Rapid Link 4.0 General information on Engineering The Rapid Link 4.0 electronic drive system enables remote and flexible installation in the direct proximity of the drive unit. The entire system is designed with protection to IP65. All electrical connections (mains voltage, motor feeder, sensors) are implemented simply with the standard connectors that are primarily used in materials handling applications. ① ② ③ ⑤ ④ a b c d e Sensor (light barriers) RAMO Motor connection cable Mains connection on power bus AS-Interface Motor starter selection Electrical mains connection Safety and protective device EMC compliance All motor starters (RAMO, RASP) can provide electronic motor protection and the additional connection of temperature sensors (thermistor, ThermoClick, PTC). The motor starters are available in the following variants, with or without a lockable repair switch (mains transfer switch): The motor starters can be connected to and operated on 400 V three-phase, star point-earthed AC supply systems (in accordance with IEC 60364) without any restriction. The neutral conductor must be connected for motor starter variants that actuate a 230 V motor brake. The power bus must have shortcircuit protection. The length of the power bus depends on the upstream group protection. Calculations for design examples are provided in the Rapid Link manual (MN03406003Z): All motor starters observe the required EMC limit values when connected as specified. The RASP frequency-controlled motor starter must be provided with a shielded motor cable (RASP-CM1-…) and installed with the specified EMC measures. The internal RFI filter then allows operation in accordance with category C3 in the second environment. • RAMO-D, electronic DOL starter for one operating direction. • RAMO-W, electronic reversing starter (two operating directions). • RASP, frequency-controlled motor starter with several speeds for two operating direction in assigned ratings. • PKZM0-25 motor-protective circuitbreaker, max. approx. 40 m. • FAZ C25/3 miniature circuit-breaker, max. approx. 60 m. • PKE32/XTU-32 system protective circuit-breaker, 50 m to 220 m. The group protective devices listed here protect: • the power bus from overloads and short-circuits. • the spur lines to the motor starter (RAMO, RASP) from overloads and short-circuits. • the motor feeder of the RAMO On the RASP frequency-controlled motor starter, the motor feeder is protected by the internal variable frequency drive. When using residual current devices, a Type B AC/DC sensitive residual current circuit-breaker must be used with the RASP frequency-controlled motor starter. CA04020001Z-EN-INT www.eaton.eu Rapid Link 4.0 165 General information on Engineering Terminal Models Example RASP: RA-C1, flat cable system 3 AC, (N), PE 50/60 Hz ① ② Connection from below (standard) • a three-phase AC motor (U1, V1, W1, PE), • a motor brake (B1, B2) with a control voltage of 230 V AC or 400 V AC, • a thermistor or temperature switch (ThermoClick). These connection cables (T1, T2) can at the same time be used to monitor the motor cable and the connection of the motor feeder plug. 4 a 5-pole power connector for connecting the 3 AC 400 V mains voltage, (N), PE. b 8-pole motor feeder socket as per DESINA specification. By rotating the base 90 degrees, connection is also possible from the right or left. This makes it possible to keep the operating and connection area and the heat sink on the RASP in the preferred vertical position. RA-C2, round cable system with plug connectors The 8-pole motor feeder can be used to connect: 6 5 8 1 7 3 PE 3 AC, (N), PE 50/60 Hz RA-C4, round cable system with contact connectors Connection from the right (90 degree rotation of the base to the left) Three installation systems are available for connecting the power plug to the mains: Device variants with a repair switch (RAMO-…-C32R…, RASP-….C32R…) ensure that the drive can be isolated locally from the power supply for repair or maintenance work, even when it is still connected. A padlock can be used to secure the repair switch. 3 AC, (N), PE 50/60 Hz PES B2 B1 T1 T2 U V W ≦ 5 m (≦ 16.4 ft) The electrical connection in the power section (mains voltage, motor feeder) is implemented with plug-in terminals in the base. PE M3∼ ϑ Example: Motor feeder with shielded motor cable on the RASP Control level The control level features a selector switch (key switch) for selecting automatic mode and manual mode locally. The RAMO-W and RASP motor starters are also provided with a selector switch for reversing the motor direction in manual mode. OFF/RESET The automatic mode and the control voltage power supply are implemented via the AS-Interface. All connections in the control level (AS-i, sensors etc.) are implemented with M12 plug connectors. For this the M12 connectors just have to be fitted on [1] and rotated to secure them [2] (see illustration below). 0 I II OFF FWD On the RAMO-DA… and RAMO-WA… a 24 V DC output (max. 1 A, O3) also makes it possible to control external actuators (valves, couplings, indicator lights) directly. The functions are selected directly on the motor starter via microswitches. On the RASP additional settings (variable frequency drives) can be made from a hand-held terminal or from the parameter software. Rapid Link REV The sensor inputs (I3, I4) enable the Rapid Link motor starters to execute sensor-controlled functions immediately and independently of PLC and bus cycle times: • Interlocked manual operation, • Quick Stop, • Rotation direction change (on RAMO-W and RASP), • Controlled speeds (only RASP) I3 I4 1 2 UV M 3~ ≦ 20 m (≦ 65.6 ft) CA04020001Z-EN-INT www.eaton.eu 166 Rapid Link 4.0 Connection examples Engineering Connection examples 4 4 4 4 1 3 6 Optional features: ① RAMO-D…-C32R… Repair and maintenance switch ② Actuation of external brake (230 V), RAMO-Dx2… ③ Actuator output, RAMO-DA… CA04020001Z-EN-INT www.eaton.eu T2 M3∼ ϑ V 7 3 8 6 4 PE 5 1 ① 4 5 2 1 3 L1 1 1 U 7 L2 2 W T1 3 PE PE ② 5 3 PE L3 B1 N 4 4 B2 5 8 1 +24 V < 160 m A 1 ASi+ 2 (0 V) 2 3 0V 4 ASi- (+24 V) I3 3 1 3 (2) 2 3 I4 1 (4) 1 2 3 3 ③ O3 +24 V ≤1A 4 Block diagram RAMO-D DOL starter Rapid Link 4.0 167 Connection examples 4 4 4 4 1 3 B1 4 ① RAMO-D…-C32R… Repair and maintenance switch ② Actuation of external brake (400 V), RAMO-Dx4… ③ Actuator output, RAMO-DA… CA04020001Z-EN-INT www.eaton.eu Rapid Link T2 M3∼ ϑ W V 7 3 8 6 4 PE 5 ① 3 4 5 1 1 1 U 7 2 L2 L1 1 2 T1 3 PE ② PE 6 4 5 3 PE L3 B2 5 8 1 +24 V < 160 m A 1 ASi+ 2 (0 V) 2 3 0V 4 ASi- (+24 V) I3 3 1 3 (2) 2 3 1 (4) I4 1 2 3 3 ③ O3 +24 V ≤1A 4 Block diagram DOL starter RAMO-D 168 Rapid Link 4.0 Connection examples 4 4 4 4 1 3 6 Optional features: ① Repair and maintenance switch RAMO-W…-C32R… ② Actuation of external brake (230 V), RAMO-Wx2… ③ Actuator output, RAMO-WA… CA04020001Z-EN-INT www.eaton.eu T2 M3∼ ϑ V 7 3 8 6 4 PE 5 1 ① 4 5 2 1 3 L1 1 1 U 7 L2 2 W T1 3 PE PE ② 5 3 PE L3 B1 N 4 4 B2 5 8 1 +24 V < 160 m A 1 ASi+ 2 (0 V) 2 3 0V 4 ASi- (+24 V) I3 3 1 3 (2) 2 3 1 (4) I4 1 2 3 3 ③ O3 +24 V ≤1A 4 Block diagram RAMO-W reversing starter Rapid Link 4.0 169 Connection examples 4 4 4 4 1 3 B1 4 Optional features: ① Repair and maintenance switch RAMO-W…-C32R… ② Actuation of external brake (400 V), RAMO-Wx4… ③ Actuator output, RAMO-WA… CA04020001Z-EN-INT www.eaton.eu Rapid Link T2 M3∼ ϑ W V 7 3 8 6 4 PE 5 ① 3 4 5 1 1 1 U 7 2 L2 L1 1 2 T1 3 PE ② PE 6 4 5 3 PE L3 B2 5 8 1 +24 V < 160 m A 1 ASi+ 2 (0 V) 2 3 0V 4 ASi- (+24 V) I3 3 1 3 (2) 2 3 1 (4) I4 1 2 3 3 ③ O3 +24 V ≤1A 4 Block diagram RAMO-W reversing starter 170 Rapid Link 4.0 Connection examples 3 4 4 2 (b) 3 2 4 4 (a) 2 1 I3(b) 0 V 3 6 Optional features: ① Repair and maintenance switch, RASP-…-C32R… ② Actuation of external brake (230 V), RASP-…xx2… ③ Device fan, RASP-…L-C32… ④ internal braking resistance, RASP-x1… CA04020001Z-EN-INT T2 M3∼ ϑ V 7 3 8 6 4 PE 5 1 ① 4 5 2 1 3 ④ L1 1 1 U 7 L2 2 W T1 3 PE PE ② 5 3 PE L3 B1 N 4 4 B2 5 8 1 +24 V < 160 m A 1 ASi+ 2 (0 V) 3 4 ASi- (+24 V) I3a 1 3 (2) I4(b) 3 1 (4) I4a 1 2 ③ 3 M 4 F +24 V ≤ 100 mA 0 V +24 V RJ 45 Block diagram RASP www.eaton.eu Note: Y connector RA-XM12-Y is required in order to connect 4 sensors (I3a, I3b/I4a, I4b) (→ accessory) Rapid Link 4.0 171 Connection examples 3 4 4 2 (b) 3 2 4 4 (a) 2 1 I3(b) 0 V 3 B1 4 6 7 3 Optional features: ① Repair and maintenance switch, RASP-…-C32R… ② Actuation of external brake (400 V), RASP-…xx4… ③ Device fan, RASP-…L-C32… ④ internal braking resistance, RASP-x1… Note: Y connector RA-XM12-Y is required in order to connect 4 sensors (I3a, I3b/I4a, I4b) (→ accessory) CA04020001Z-EN-INT www.eaton.eu Rapid Link M3∼ ϑ 8 6 4 PE 5 1 ① 4 5 2 1 3 ④ L1 1 1 U 7 V W T1 3 PE PE ② 2 L2 T2 4 5 3 PE L3 B2 5 8 1 +24 V < 160 m A 1 ASi+ 2 (0 V) 3 4 ASi- (+24 V) I3a 1 3 (2) I4(b) 3 1 (4) I4a 1 2 ③ 3 M 4 F +24 V ≤ 100 mA 0 V +24 V RJ 45 Block diagram RASP 172 Rapid Link 4.0 Motor starter RAMO, speed controller RASP Technical data Motor starter RAMO, speed controller RASP RAMO-D… RAMO-W… RASP-2… RASP-3… RASP-4… RASP-5… General Standards Climatic proofing IEC/EN 60947-4-2 IEC/EN 60947-5-1 IEC/EN 61000-6-2 IEC/EN 61000-6-4 Directive 2002/95/EG (RoHS) CE approval < 95%, non-condensing IEC/EN 50178 EN 61800-5-1 EN 61800-3 Directive 2002/95/EG (RoHS) CE approval ρw % Operation ϑ °C -10 - +55 -10 - +55 Storage ϑ °C -30 - +70 -30 - +70 0 - +40 0 - +55 (with fan RASP-FAN-1) -30 - +70 -30 - +70 -30 - +70 -30 - +70 III III III III III III 4 4 2 2 2 2 Device class A Device class A m 10 10 2. Environment, Class C3 5 2. Environment, Class C3 5 2. Environment, Class C3 5 2. Environment, Class C3 5 g 1000 shocks per shaft, semi-sinusoidal 15 g/11 ms IEC/EN 60068-2-27 Oscillation frequency: 10 - 150 Hz Amplitude 0.15 mm: 6 Hz Amplitude transition frequency on acceleration: 57 Hz IEC/EN 60068-2-6 Vertical Vertical Vertical Vertical Vertical Vertical m 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 2000 m IP65 IP65 IP65 IEC/EN 60529 IEC/EN 60529 IEC/EN 60529 IP65 IEC/EN 60529 IP65 IEC/EN 60529 IP65 IEC/EN 60529 kg 1.6 1.7 4.2 4.2 4.2 4.4 kg 1.9 1.9 4.4 4.4 4.4 4.6 Ambient temperature Overvoltage category Rated impulse withstand voltage Radio interference level Uimp kV Environment (EMC) longest permissible length of motor cable Mechanical shock resistance I Vibration Mounting position Altitude Protection type 0 - +45 Weight without manual override switch with manual override switch Main circuit Supply Rated operational voltage Ue Mains voltage (50/60Hz) ULN V 400 V AC 400 (-15%) - 415 (+10%) 400 V AC 380 (-15%) - 400 (+10%) Input current ILN T ≤ 6.6 3.2 4 5.6 7.3 50/60 50/60 50/60 47 - 66 Hz (± 0%) 47 - 66 Hz (± 0%) 47 - 66 Hz (± 0%) 47 - 66 Hz (± 0%) ≤ 6.6 Supply frequency fLN Hz AC voltage Center-point earthed star network (TN-S network) Phase-earthed AC supply systems are not permitted. 50/60 50/60 50/60 Frequency range fLN Hz 47 - 63 Hz (± 0%) System configuration 47 - 63 Hz (± 0%) max. one time per minute Mains switch-on frequency Mains current distortion THD % - - > 120 > 120 > 120 > 120 Rated conditional shortcircuit current Short-circuit protective device Iq kA < 10 < 10 <5 <5 <5 <5 CA04020001Z-EN-INT Type 1 coordination via the power bus' feeder unit www.eaton.eu Rapid Link 4.0 173 Motor starter RAMO, speed controller RASP RAMO-D… RAMO-W… RASP-2… RASP-3… RASP-4… DOL starter with thyristors and bypass contacts, 2-phase Frequency inverter with internal DC link and IGBT inverter RASP-5… Power section Function On-delay tON ms 20 - 35 Reversing starter with relays, thyristors and bypass contacts, 2-phase controlled 20 - 35 30 - 50 30 - 50 30 - 50 30 - 50 Off-delay tOFF ms 20 - 35 20 - 35 15 - 35 15 - 35 15 - 35 15 - 35 Lifespan, mechanical Operat ions Operat ions AC3: > 10.000.000 AC3: > 10.000.000 - - - - AC3: > 10.000.000 AC3: > 10.000.000 - - - - Lifespan, electrical Overload cycle AC-53a AC-53a - - - - Overload current for 60 s every 600 s Starting current for 2 s IL A - - 3.6 (at 40 °C) 5 (at 40 °C) 6.5 (at 40 °C) 8.4 (at 40 °C) IL A - - 4.8 (at 40 °C) 6.6 (at 40 °C) 8.6 (at 40 °C) 11.2 (at 40 °C) Output voltage with Ve U2 = ULN = ULN 0 - ULN 0 - ULN 0 - ULN 0 - ULN Output Frequency f2 Hz = fLN = fLN 0 - 50 Hz (max. 320 Hz) Switching frequency fPWM kHz - - - - 6 (adjustable 1.5 - 16) linear, parameterizable Δf Hz - - 0.01 0.01 0.01 0.01 Ie A 6.6 6.6 2.4 3.3 4.3 5.6 - 0.3 - 6.6 adjustable - Rated operational current at an operating frequency of 6 kHz and an ambient air temperature of +40 °C 0.48 - 4.8 0.66 - 6.6 0.86 - 8.6 1.12 - 11.2 adjustable adjustable adjustable adjustable 0.95 0.95 0.96 0.96 Operation Mode Frequency resolution (setpoint value) Rated operational current Note Motor current limit I A Efficiency η % 0.3 - 6.6 adjustable - Maximum leakage current to ground (PE) without motor Fan IPE mA - - 3.5 - - internal, temperature controlled optional RASP-FAN-S1 on heat sink, temperaturecontrolled 3.5 3.5 3.5 internal and on heat sink, temperaturecontrolled Motor feeder Assigned motor rating at 400 V, 50 Hz Actuator for external motor brake Breaking voltage Braking current P A U V for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz - 230 V AC -15% / +10% 400 V AC -15% / +10% ≤ 0.6 A ≤ 0.6 A (max. 6 A for (max. 6 A for 120 ms) 120 ms) 230 V AC -15% / +10% 400 V AC -15% / +10% ≤ 0.6 A ≤ 0.6 A (max. 6 A for (max. 6 A for 120 ms) 120 ms) ≤ 0.6 A (max. 6 A for 120 ms) ≤ 0.6 A (max. 6 A for 120 ms) I A Braking torque % I/Ie - - ≦ 30 ≦ 30 ≦ 30 ≦ 30 Switch-on threshold for the braking transistor DC braking UDC V - - 765 V DC 765 V DC 765 V DC 765 V DC % I/Ie - - ≦ 100, adjustable Uc V 24 V DC - 15 % / + 20 % via AS-Interface® plug Braking function Control section External control voltage AS-Interface® RAMO-…AI1… RASP… RAMO-…AI2… max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA Specification: S-7.4 Number of slave addresses: 31 Specification: S-7.A.E. Number of slave addresses: 62 Specification: S-7.4 Number of slave addresses: 31 - CA04020001Z-EN-INT www.eaton.eu Rapid Link Note 174 Rapid Link 4.0 Rapid Link 4.0 Accessories 175 Accessories Accessories Flat cable Distributor module Distributor module Flexible busbar junction 400 V AC/24 V DC RA-C1-PLF Round cable junction Round cable junction RA-C1-7X4HF RA-C1-AM-7 RA-C1-VM-7 RA-C2-S1-4 RA-C4-PB65 Standards IEC 60332-1 DIN VDE 0295 Class 6 DIN VDE 0281 Part 404 Protection type IP65 IEC/EN 60529 As required DIN/EN 60664-1 DIN/EN 60529 DIN/EN 60999 DIN VDE 0470 Part 1 IP65 IEC/EN 60529 As required IEC/EN 60047-7-1 DIN VDE 0470 Part 1 IEC/EN 68000-2-27 IEC/EN 60998-3 DIN VDE 0660 Part 1535 EN 61684 DIN VDE 0110 DESINA - IP65 IEC/EN 60529 As required IP65 IEC/EN 60529 As required IP65 IEC/EN 60529 As required IP65 IEC/EN 60529 As required General Mounting position Ambient temperature Operation ϑ °C -15 - +50 -15 - +40 -15 - +50 -15 - +50 -15 - +50 -40 - +55 Storage ϑ °C -5 - +70 -5 - +50 -5 - +50 -5 - +50 -5 - +50 -10 - +40 Flame retardance, fire propagation Self-extinguishing to IEC 60332-1 - - - - - Resistance to oils and acids To VDE 0473, Part 811-2-1 - - - - - Sheathing - - - - - Minimum bending radius mm Material according to DIN VDE 0282, EVA mixture EM4, black 18 - - - - - Cable weight kg/km 440 - - - - - Outer dimensions L x W x H mm L x 34.8 x 6.0 160 x 60.2 x 59.5 175 x 83 x 78 119 x 57.5 x H 158 x 112.5 x 55 181 x 104 x 67 Overvoltage category - III III III III III Pollution degree - 3 3 3 3 3 Termination - Springloaded terminals 1.5 to 4 mm² Twin-level terminal block, 1.5 to 4 mm² IDC termination Piercing/screw terminals Insulation piercing terminals - V-M25: 9 - 17 V-M20: 6 - 13 9 - 17 - 10 - 13 13 - 16 11 - 13 13 - 15 15 - 17 Outer cable diameter mm Main circuit Rated operational voltage Ue Rated operational current Ie Line protection 500 V AC 500 V AC 500 V AC 500 V AC 500 V AC 690 V AC A 25 25 25 - 20/25 (2.5 mm2/4 mm2) 25 (4 mm2) Type PKE32/XTU-32 PKZM0-25 FAZ-C25/3 PKE32/XTU-32 PKZM0-25 FAZ-C25/3 PKE32/XTU-32 PKZM0-25 FAZ-C25/3 PKE32/XTU-32 PKZM0-25 FAZ-C25/3 PKE32/XTU-32 PKZM0-25 FAZ-C25/3 PKE32/XTU-32 PKZM0-25 FAZ-C25/3 Rated operational voltage Ue V 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC - Rated operational current Ie A 25 10 25 - 20/25 (2.5 mm2/4 mm2) - Rapid Link Control circuit Dimensions Motor cable and motor feeder plug RAMO-CM1-2M0 /-5MO /-10MO Motor cable and motor feeder plug RASP-CM1-2M0 /-5MO EN 61684 DIN VDE 0110 IP65 IEC/EN 60529 EN 61684 DIN VDE 0110 IP65 IEC/EN 60529 Motor starter RAMO without manual override switch with manual override switch Protection type 145 Standards 120 General Ambient temperature Operation ϑ °C -30 - +70 -30 - +70 Terminal capacities mm2 8 x 1.5 4 x 1.5 + 2 x (2 x 0.75) screened Outer cable diameter mm 9 - 13 9 - 13 Minimum bending radius mm 6 x outer cable diameter 10 x outer cable diameter Conductor material - - Material Colour Outer casing halogen free Cable: Cu flexible to VDE 0295 Class 5 Silver grey (RAL 7001) Outer casing halogen free Cable: Cu flexible to VDE 0295 Class 6 Orange (RAL 2003) Resistance to oils and acids VDE 0472 Part 803 B VDE 0472 Part 803 A/B Flame retardance, fire propagation EN 50265-2-1 IEC 60332-2 Contact pins: 8 x 1.5 Contact pins: 4 x 1.5 + 4 x 0.75 Contacts Polycarbonate Polycarbonate Contact material Cu silver-plated Cu silver-plated Housing Polycarbonate Polycarbonate Locking facility Polyamide Polyamide Connection cable II I 0 245 285 245 270 Metal housing with plug-in connection mm2 Conductor cross-section II I 0 Material CA04020001Z-EN-INT www.eaton.eu 173 220 ⌀ 6.2 173 220 ⌀ 6.2 CA04020001Z-EN-INT www.eaton.eu 176 Rapid Link 4.0 RASP speed controllers RASP speed controllers RASP speed controllers Device fans RASP-FAN-S1 with fan without manual override switch without manual override switch 157 195 45 without fan 190 0 I II 146 0 245 270 245 270 I II 173 220 ⌀ 6.2 173 220 with manual override switch 220 182 with manual override switch ⌀ 6.2 II I 0 245 285 245 285 II I 0 173 220 CA04020001Z-EN-INT ⌀ 6.2 173 220 www.eaton.eu ⌀ 6.2 Rapid Link 4.0 177 Accessories Accessories Accessories flexible busbar junction Locking brackets RA-C1-PLF RA-C1-PLF1 SET-M-LOCK 35 o 8.5 57.5 M5 65 50 119 M4 47.5 35 109 Distributor module 59.5 6.5 5 70 37.2 36.7 4.5 83 RA-C1-VM-7 60.2 RA-C1-AM-7 160 162.5 3.3 175 78 48.2 RA-C1-VP-AM-2 47.5 55 6.5 M4 4.5 132 107 6 115 54.5 Round cable junction 27 25.5 55 RA-C2-S1-4 78.5 112.5 5.5 158 Rapid Link 130 142.5 Locking brackets 89 7 104 RA-C4-PB65 165 181 6 67 CA04020001Z-EN-INT www.eaton.eu ® SmartWire-DT™ – Cost-optimized communication for switchgear Manufacturers of machines and systems strive to achieve a balance between the maximum level of functionality and cost optimization. Designed for further development, SmartWire-DT is a communication system for industrial switchgear in control panels and the periphery: from control, protection and switching to actuation, operation and monitoring. One technology from which you will profit, now and in the future. Taxes Contactors Switching Operation & monitoring Driving PowerXL variable frequency drives and DS7 soft starters – Communicate with SmartWire-DT Being able to use a controller to directly access all of a soft starter's and/or variable frequency drive's parameters via SmartWire-DT is the epitome of ease of operation. Users can read and overwrite potentiometer settings. Extended status, error, and diagnostic messages can be retrieved directly. The result: absolute data transparency. The plug-in units make installation fast and foolproof, and the resulting connection includes the soft starter's control current supply. SmartWire-DT modules for expanding the functionality of the variable frequency drives in the DC1 and DA1 series are scheduled to hit the market soon. This will enable users to communicate with their variable frequency drives via SmartWire-DT on the basis of the relevant Profidrive profile. Other profiles will also be available for simple applications. Another important function that will complement the ability to change parameters in variable frequency drives will be the ability to use extended diagnostic functions. Within this context, function blocks will make it easy to connect to Eaton PLCs and HMIs. SmartWire-DT™ 179 SmartWire-DT System overview 180 Ordering SmartWire-DT Gateways 182 SmartWire-DT accessories 182 Technical Data SmartWire-DT Gateways 184 SmartWire-DT accessories 186 Dimensions 188 SmartWire-DT accessories 188 SmartWire-DT® SmartWire-DT Gateways CA04020001Z-EN-INT www.eaton.eu 180 SmartWire-DT® Moeller® series System overview 4 5 3 5 5 2 2 1 8 4 12 9 5 11 7 10 6 6 6 6 5 6 10 13 4 14 25 16 15 17 18 12 21 22 11 23 20 19 4 5 10 20 10 6 4 6 6 6 6 CA04020001Z-EN-INT www.eaton.eu 24 SmartWire-DT® 181 System overview Moeller® series 1 SmartWire-DT HMI-PLC → Industrial Switchgear 2011 catalog SmartWire-DT module for variable frequency drives 10 → page 33 Data plug Sub-D 9 pole SmartWire-DT adapter for flat/round cable for top-hat rail mounting 19 → page 183 2 DC1 variable frequency drive SmartWire-DT Gateways 3 → page 12 4 → page 20 11 DA1 variable frequency drives 5 SmartWire-DT flat ribbon cable 8 pole 12 21 Motor-protective circuit-breaker PKE12, PKE32 → page 182 → page 182 20 → Industrial Switchgear 2011 catalog → page 182 SmartWire-DT blade terminal 8 pole SmartWire-DT PKE (motor-protective circuit-breaker) SmartWire-DT universal module, front mount 13 → Industrial Switchgear 2011 catalog Soft starter DS7 < 32 A → page 183 22 → page 111 SmartWire-DT external device plug 8 pole 6 SmartWire-DT control panel cable entry for flat to round cable 14 Soft starter DS7 > 32 A → page 183 → page 182 SmartWire-DT PKE module (motor starter) 7 23 → page 111 SmartWire-DT plug connector 15 → page 183 SmartWire-DT bus termination resistor for 8-pole flat band conductor 24 → page 183 → Industrial Switchgear 2011 catalog Motor starter with PKE electronic motor protection 8 RMQ-Titan surface-mounting enclosure with RMQ-Titan elements 16 SmartWire-DT planning and ordering aid, SWD-Assist → Industrial Switchgear 2011 catalog 25 → Industrial Switchgear 2011 catalog SmartWire-DT plug connector Soft starter DS7 with electronic motor protection from PKE → Industrial Switchgear 2011 catalog 9 17 → page 183 SmartWire-DT round cable, 8-pole 18 → page 183 System overview Note: You can find the entire SmartWire-DT range of products by consulting our industrial main catalog or our online catalog at http://ecat.moeller.net Features SmartWire-DT Gateways • Connection of SmartWire-DT to field bus. • Field bus address setting with dip switches • Automatic baud rate detection • Feeding the supply voltage for the SmartWire-DT modules • Supplies the control voltage for the motor starter or contactor • Configuration button for automatic addressing of the SmartWire-DT module. • Support of up to 99 SmartWire-DT modules. SmartWire-DT module • Function element for connecting to RMQ-Titan pilot devices. • Function element for connecting to DLM contactors • Function element for connecting to PKZ/PKE motor-protective circuitbreakers • Function module for connecting to NZM2,3,4 circuit-breakers • Connection of digital and analog input/output modules • DS7 Soft starter connection • Function element for connecting to PowerXL™ DC1, DA1 variable frequency drives SmartWire-DT Assist (SWD-Assist) • Easy creation of SmartWire-DT networks • Integrated validity check • Generation of ordering lists. • Online-Functionality – Simple pre-commissioning – Configuration check and comparison – Display of parameters and diagnostics – Easy diagnostics of SmartWire-DT module • Free download under: http://downloadcenter.moeller.net SmartWire-DT® SmartWire-DT HMI-PLC • with SmartWire-DT master interface and PLC function • Compact design with light plastic enclosures • Wide selection of onboard interfaces • 3.5” , 5.7” or 7” TFT-LCD screen CA04020001Z-EN-INT www.eaton.eu 182 SmartWire-DT® Gateways, accessories Moeller® series Ordering Gateways, accessories Description Baud Rates Number of SmartWireDT slaves Part no. Article no. Max. 58 EU5C-SWD-DP 116308 Price see price list Std. pack Information relevant for export to North America 1 off UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification SmartWire-DT Gateways supply of the SmartWire-DT modules and switchgear For connection to PROFIBUS-DP field bus field bus connection through 9-pin SUB-D socket Separate RS232 diagnostics interface (RJ45) For connection to CANopen® field bus Field bus connection through 9-pin SUB-D plug Separate RS232 diagnostics interface (RJ45) For connection to the Ethernet-IP/MODBUS-TCP field bus Field bus connection via Ethernet Switch Separate RS232 diagnostics interface (RJ45) for connection to field bus PROFINET as PROFINET IODevice Field bus connection via Ethernet Switch Separate USB diagnostics interface (Mini-USB) up to 12 MBit/ s up to 1 MBit/s Max. 99 EU5C-SWD-CAN 116307 10/100 MBit/s Max. 99 EU5C-SWD-EIPMODTCP 153163 100 MBit/s Max. 99 EU5C-SWDPROFINET 170124 1off UL File No. UL Category Control No. CSA File No. North America Certification E29184 NKCR 2324643 3211-07 UL listed, CSA certified E221530 NRQA UL report applies to both US and Canada UL listed, CSA certified Flat band conductor, 8 pole For connecting the SmartWire-DT modules within the control panel 8 pole not ready-assembled Length 100 m not ready-assembled Length 3m Length 5m Length 10 m SWD4-8SF2 SWD4-8SF2 SWD4-8S SWD4-100LF8-24 116026 SWD4-3LF8-24-2S 116027 SWD4-5LF8-24-2S 116028 SWD4-10LF8-242S 116029 1 off SWD4-8SF2-5 116022 10 off UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification E29184 NKCR 2324643 3211-07 UL listed, CSA certified External device plugs For connecting the ribbon cable to SmartWire-DT modules UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification E29184 NKCR 2324643 3211-07 UL listed, CSA certified Link For bridging open mounting locations for external device plugs Front fixing SWD4-SEL8-10 116021 5 off UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification E29184 NKCR 2324643 3211-07 UL listed, CSA certified Blade terminal For connecting the ribbon cable to the gateway, power feeder module, coupling, bus termination resistor SWD4-8MF2 116023 10 off UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification E29184 NKCR 2324643 3211-07 UL listed, CSA certified Coupling Coupling blade terminal 8-pole SWD4-8SFF2 -5 + 15V CA04020001Z-EN-INT www.eaton.eu SWD4-8SFF2-5 116024 1 off UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification E29184 NKCR 2324643 3211-07 UL listed, CSA certified SmartWire-DT® 183 Accessories Moeller® series Accessories Description Part no. Article no. For connecting each SmartWire-DT line SWD4-RC8-10 116020 Price see price list Std. pack Information relevant for export to North America 1 off UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification Network terminator SWD4-RC810 + 15V E29184 NKCR 2324643 3211-07 UL listed, CSA certified Cable adapters 1 2 3 4 5 6 7 8 for connection flat cable (plug) on round cable (terminal) SWD4-8FRF-10 121377 1 off UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification E29184 NKCR 2324643 3211-07 UL listed, CSA certified +15 V Switch cabinet bushing for transition from SmartWire-DT ribbon cable to round cable Connection of ribbon cable with blade terminal SWD4-8MF2 8 pole double conductor run pluggable Additional control voltage feeder for the motor starter and contactors. Connection round cable via socket Connection round cable via plug SWD4-SFL8-20 121380 SWD4-SML8-20 121381 1 off 1 off UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification E29184 NKCR 2324643 3211-07 UL listed, CSA certified Round conductor For laying the SmartWire-DT network outside of the control panel. For connecting the SmartWire-DT module outside the control panel 8 pole HK-S0-Li2YY, 8 mm diameter Length 50 m SWD4-50LR8-24 116030 1 off UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification E29184 NKCR 2324643 3211-07 UL listed, CSA certified Connectors for SWD round conductors 8 pole socket Straight 8-pinplug connector Straight 8 pole socket 90° angled 8-pinplug connector 90° angled SWD4-SF8-67 116033 SWD4-SM8-67 116034 SWD4-SF8-67W 116035 SWD4-SM8-67W 116036 1 off Pliers for connecting external device plug and ribbon cable Pliers for making contacts with blade terminals and ribbon cables SWD4-CRP-1 116025 SWD4-CRP-2 116699 1 off UL/CSA certification not required M22-SWD-NOP 147637 20 off North America Certification UL File No. UL Category Control No. CSA File No. CSA Class No. North America Certification E29184 NKCR 2324643 3211-07 UL listed, CSA certified Tools for plugs for configured but not yet installed SmartWire-DT slaves Front mount Configuration 1 4 3 6 2 5 CA04020001Z-EN-INT Request filed for UL and CSA www.eaton.eu SmartWire-DT® Universal slave 184 SmartWire-DT® Gateways Technical data Gateways EU5C-SWD-DP EU5C-SWD-CAN EU5C-SWD-EIP-MODTCP General Standards Dimensions (W x H x D) mm IEC/EN 61131-2 EN 50178 35 x 90 x 127 Weight kg 0.16 35 x 90 x 124 0.16 Mounting Top-hat rail IEC/EN 60715, 35 mm Mounting position As required 0.17 Ambient conditions, mechanical Protection type (IEC/EN 60529, EN50178, VBG 4) IP20 IP20 IP20 Vibrations (IEC/EN 61131-2:2008) Constant amplitude 3,5 mm Hz 5 - 8.4 5 - 8.4 5 - 8.4 Constant acceleration 1 g Hz 8.4 - 150 8.4 - 150 8.4 - 150 Impacts 9 9 9 mm 50 50 50 m 0.3 0.3 0.3 Overvoltage category II II II Pollution degree 2 2 2 Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms Drop to IEC/EN 60068-2-31 Fallhöhe Free fall, packaged (IEC/EN 60068-2-32) Electromagnetic compatibility (EMC) Electrostatic discharge (IEC/EN 61131-2:2008) Air discharge (Level 3) kV 8 8 8 Contact discharge (Level 2) kV 4 4 4 Electromagnetic fields (IEC/EN 61131-2:2008) 80 - 1000 MHz V/m 10 10 10 1.4 - 2 GHz V/m 3 3 3 2 - 2.7 GHz V/m 1 1 1 Radio interference suppression (SmartWire-DT) EN 55011 Class A Burst (IEC/EN 61131-2:2008, Level 3) Supply cables kV 2 2 2 CAN/DP bus cable kV 1 1 1 SmartWire-DT cables kV 1 1 1 Surge (IEC/EN 61131-2:2008, Level 1) Supply cables/CAN/DP bus cable Supply cables 0.5 kV, CAN/DP bus cable 1 kV Radiated RFI (IEC/EN 61131-2:2008, Level 3) V 10 10 10 °C - 25 - + 55 - 25 - + 55 - 25 - + 55 Climatic environmental conditions Operating ambient temperature (IEC 60068-2) Take appropriate measures to prevent condensation Condensation Storage °C - 40 - + 70 - 40 - + 70 - 40 - + 70 relative humidity, non-condensing (IEC/EN 60068-2-30) % 5 - 95 5 - 95 5 - 95 Rated operational voltage V 24 V DC (-15/+20%) Residual ripple on the input voltage % ≦5 ≦5 ≦5 Yes Yes Yes 3 3 3 Supply voltage UAux Protection against polarity reversal Max. current Imax A If contactors with a total power consumption > 3 A are connected, a power feeder module EU5C-SWD-PF1/2 has to be used. no, external fuse FAZ Z3 Short-circuit rating Power loss W Potential isolation Rated operating voltage of 24-V-DC slaves CA04020001Z-EN-INT www.eaton.eu V Normally 1 Normally 1 Normally 1 No No No typ. UAux - 0.2 typ. UAux - 0.2 typ. UAux - 0.2 SmartWire-DT® 185 Gateways EU5C-SWD-DP EU5C-SWD-CAN EU5C-SWD-EIP-MODTCP Supply voltage UPow Supply voltage V 24 DC -15 % + 20 % 24 DC -15 % + 20 % 24 DC -15 % + 20 % Input voltage ripple % ≦ 5 ≦ 5 ≦ 5 yes yes yes 0.7 0.7 0.7 yes yes yes Siemens MPI, (optional) Rated current I A Overload proof Inrush current and duration A 12.5 A/6 ms 12.5 A/6 ms 12.5 A/6 ms Heat dissipation at 24 V DC W 3.8 3.8 3.8 No No No Potential isolation between UPow and 15 V SmartWire-DT supply voltage Bridging voltage dips ms 10 10 10 Repetition rate s 1 1 1 Status indication LED yes yes yes SmartWire-DT supply voltage Rated operating voltage Ue V 14,5 ± 3 % 14,5 ± 3 % 14,5 ± 3 % max. current Imax A 0.7 0.7 0.7 If SmartWire-DT modules with a total power consumption > 0.7 A are connected, a power feeder module EU5C-SWD-PF2 has to be used. Yes Yes Yes Short-circuit rating Connection supply and inputs/outputs Connection type Push in terminals Solid mm2 0.2 - 1.5 0.2 - 1.5 0.2 - 1.5 Flexible with ferrule mm2 0.25 - 1.5 0.25 - 1.5 0.25 - 1.5 UL/CSA solid or stranded AWG 24 - 16 24 - 16 24 - 16 SmartWire-DT network Station type SmartWire-DT master 58 99 99 kBd 125 250 automatic 125 250 automatic 125 250 automatic LED Connection SmartWire-DT SmartWire-DT master LED: green Configurations LED: red Plug, 8-pole Plug connectors Blade terminal SWD4-8MF2 Number of SmartWire-DT slaves Baud Rates Address allocation Status indication Function PROFIBUS DP slave CANopen® slave Input data, max. Byte 240 128 Output data, max. Byte 240 128 Baud Rates up to 12 MBit/s up to 1 MBit/s Ethernet IP/MODBUSTCP Slave Ethernet IP/MODBUSTCP Ethernet-IP: 546 MODBUS-TCP: 800 Ethernet-IP: 496 MODBUS-TCP: 642 10/100 MBit/s Protocol PROFIBUS-DP CANopen® Baud rates switching automatic automatic automatic Address 2 … 125 2 … 32 - Address allocation DIP switch DIP switch Two-coloured red/green Two-coloured red/green Terminating resistor switchable via plug DIP switches Dip switch/DHCP/ BOOTP Selection via DIP switch Link status: yellow (10 MBit), green (100 MBit) flashing - Terminal type 1 x D-SUB socket, 9-pin 1 x D-SUB socket, 9-pin Potential isolation Yes Yes Status display interface LED 2 x RJ45 (2-channel switch) Yes CA04020001Z-EN-INT www.eaton.eu SmartWire-DT® Fieldbus interface 186 SmartWire-DT® SmartWire-DT® Accessories 187 Accessories Accessories Part no. M22-SWD-NOP... SWD4-RC8-10 SWD4-8SF2-5 SWD4-8SFF2-5 SWD4-8FRF-10 SWD4-SFL8-20 SWD4-SML8-20 IEC/EN 61131-2 EN 50178 48.5 x 34.5 x 10 IEC/EN 61131-2 EN 50178 15 x 36.5 x 17.5 IEC/EN 61131-2 EN 50178 48.5 x 34.5 x 10 IEC/EN 61131-2 EN 50178 35 x 90 x 35 IEC/EN 61131-2 EN 50178 35 x 83 x 40 IEC/EN 61131-2 EN 50178 35 x 83 x 46 General Standards Dimensions (W x H x D) mm IEC/EN 61131-2 EN 50178 12 x 42 x 39 Weight kg - - - - - - - Weight g 10 10 5.5 4.5 42 50 50 As required As required As required As required As required As required As required IP20 IP20 IP20 IP20 IP20 IP67 IP67 Mounting position Ambient conditions, mechanical Protection type (IEC/EN 60529, EN50178, VBG 4) Vibrations (IEC/EN 61131-2:2008) Constant amplitude 3,5 mm Hz 5 - 8.4 5 - 8.4 5 - 8.4 5 - 8.4 5 - 8.4 5 - 8.4 5 - 8.4 Constant acceleration 1 g Hz 8.4 - 150 8.4 - 150 8.4 - 150 8.4 - 150 8.4 - 150 8.4 - 150 8.4 - 150 Impacts 9 9 9 9 9 9 9 mm 50 50 - - - - - m 0.3 0.3 - - - - - Overvoltage category Not applicable II - - - - - Pollution degree 2 2 - - - - - Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms Drop to IEC/EN 60068-2-31 Fallhöhe Free fall, packaged (IEC/EN 60068-2-32) Electromagnetic compatibility (EMC) Electrostatic discharge (IEC/EN 61131-2:2008) Air discharge (Level 3) kV 8 8 - 8 8 8 8 Contact discharge (Level 2) kV 4 4 - 4 4 4 4 Electromagnetic fields (IEC/EN 61131-2:2008) 80 - 1000 MHz V/m 10 10 - - - 10 10 1.4 - 2 GHz V/m 3 3 - - - 3 3 2 - 2.7 GHz V/m 1 1 - - - 1 1 EN 55011 Class A EN 55011 Class A - - - - - Radio interference suppression (SmartWire-DT) Burst (IEC/EN 61131-2:2008, Level 3) Supply cables kV 2 - - - SmartWire-DT cables kV 1 1 - - - - - V 10 10 - - - 10 10 °C - 30 - + 55 - 25 - + 55 - 25 - + 55 - 25 - + 55 - 25 - + 55 - 25 - + 55 - 25 - + 55 Storage °C Take appropriate measures to prevent condensation - 40 - 80 Take appropriate measures to prevent condensation - 40 - 70 Take appropriate measures to prevent condensation - 40 - 70 Take appropriate measures to prevent condensation - 40 - 70 Take appropriate measures to prevent condensation - 40 - 70 Take appropriate measures to prevent condensation - 40 - 70 Take appropriate measures to prevent condensation - 40 - 70 relative humidity, non-condensing (IEC/EN 60068-2-30) % 5 - 95 5 - 95 5 - 95 5 - 95 5 - 95 5 - 95 5 - 95 Radiated RFI (IEC/EN 61131-2:2008, Level 3) Climatic environmental conditions Operating ambient temperature (IEC 60068-2) Condensation SmartWire-DT network Station type SmartWire-DT slave - - - - - - Number - - - - - - - Baud rate setting automatic - - - - - - Green - - - - - - Connections Plug, 8-pole - - - - - - Plug connectors SWD4-8SF2-5 - - - - - - Number of insertion cycles ≥ 50 - - - - - - - - - - - - - - - - - - - - SmartWire-DT status LED LED Contacts Lifespan mechanical/electrical LED display Operations No - - - - - - Diagnostics LED Yes - - - - - - Fixing Front fixing - - - - - - SmartWire-DT® Function element Connection options SWD-In Plug, 8-pole Plug connector Plug, 8-pole Plug, 8-pole Plug, 8-pole Plug, 8-pole Number of insertion cycles ≥ 200 ≥1 ≥ 200 ≥ 200 ≥ 200 ≥ 500 SWD-Out - Socket, 8-pole Plug, 8-pole Push in terminals Socket, 8-pole Plug, 8-pole Number of insertion cycles - ≥ 200 ≥ 200 - ≥ 500 ≥ 200 CA04020001Z-EN-INT www.eaton.eu CA04020001Z-EN-INT www.eaton.eu 188 SmartWire-DT® Gateways, accessories Dimensions Gateways, accessories 90 SmartWire-DT Gateways EU5C-SWD-DP EU5C-SWD-CAN EU5E-SWD-... EU5C-SWD-PF... EU5C-SWD-EIP-MODTCP... EU5C-SWD-PROFINET NZM-XSWD-704... a 122 122 97 120 120 120 97 b 90 90 90 90 90 90 35 4.5 a Network terminator Coupling SWD4-8SF2-5 SWD4-RC8-10 SWD4-8SFF2-5 14.9 48.4 36.4 4 4 30 48.4 12.8 17.2 External device plugs 25.9 25.9 10.15 10.15 34.3 34.3 Adapter flat cable on round cable SWD4-SFL8-20 SWD4-8FRF-10 4 14 14 M18 x 0.75 Switch cabinet bushing socket SWD4-SM8-20 M18 x 0.75 Switch cabinet bushing plug 21 35 21 35 90 82.4 82.4 4 35 23.2 36 Plug connectors for SmartWire-DT round cables, flat SWD4-SF8-67W SWD4-SF8-67 o 18 37.1 37.4 o 18 SWD4-SM8-67W o 18.5 Connectors for SmartWire-DT round cables, angled 45 20 20 o 18.5 SWD4-SM8-67 44.5 30.8 30.8 55 54 CA04020001Z-EN-INT www.eaton.eu M16 x 0.75 M16 x 0.75 M16 x 0.75 Planning safety and process optimization – CAD data at the click of a mouse! • 9,500 article data items and macros • Convenient selection tool • Version P8 Eaton is providing its customers with CAD data to offer optimum support during planning. Both electrical and mechanical design data can be called up quickly and conveniently from the Internet at any time. This reduces processing times, minimizes errors and thus reduces costs already in the engineering phase of control panels, systems and machinery. eCAD: Eaton makes product data and macros available for the EPLAN planning system and the Electric P8 version. Device data for over 9,500 products can be downloaded from the Eaton website and integrated in customer article databases using a specially developed selector. • Models for approx. 10,000 products • 70 different neutral & native formats URL www.moeller.net/cad mCAD: Eaton makes 2D and 3D data available for more than 10,000 products. Over 70 different neutral and native formats guarantee compatibility with the project engineering systems of the customer. The models can either be integrated directly into the planning software from the Partcommunity Portal on the Internet or via the CADENAS Partsolution software. Worldwide export of machines and plants European machine and system building and worldwide exports are closely related. Even if you don't export your machines at present, you should be prepared for it in the future. Eaton provides switchgear and protective devices with all the essential approvals and certificates for machine and system building. In most countries around the world, conformity with international standards is the sole requirement for successful exports. This is because components in these locations are governed by compliance with well known and established IEC standards. In this respect, the European CE mark is not only the passport for exports within Europe but also far beyond its borders. World market equipment for machine building Nearly all the switchgear and protective devices of Eaton's Moeller® series are world market devices. Each product line thus carries all the approvals and certification marks required for worldwide use. These product lines include those for • Pilot devices, limit switches • Contactors and various timing and special relays • Motor-protective circuit-breakers and relays • Electronic components and systems. With circuit-breakers and switch-disconnectors, Eaton offers IEC devices for use in most countries in the world and NA devices with virtually the same dimensions and the same accessories for the North American market. This considerably simplifies device selection since the North American standards often involve the need for considerably different technical specifications. Electrical engineering products and their applications are not harmonized internationally. The greatest differences to the IEC world are in North America, i.e. the USA and Canada. For many newcomers to the export business, it is initially surprising to experience the very different approaches and solutions. Special components, such as handles for main switches that can only be operated by the intentional switching of an additional handle when the control panel door is opened, may sometimes be required for export to North America. Likewise, the European motor-protective circuit-breaker is only accepted with an upstream protective device or with larger air and creepage distances at the incoming terminals. Eaton is the competent partner of choice for export-related issues here. Qualified information is a critical key to success The Eaton Main Catalogue for Moeller® series products provides reliable information for machine and panel builders on the approval of components deployed for North American market. Each selection page provides information such as the relevant product standard, the E-File Number, the Category Control Number or the CSA Class Number. Many customers incorporate this information in their parts lists in order to be well prepared for the acceptance procedures. Up to 13 data items are listed here for each product, such as the suitability for use in feeders or branch circuits, the maximum operating voltage, or the North American degree of protection, such as UL / CSA Type 4X. The Main Catalogue also contains a glossary with explanations of the American terms. The link http://www.moeller.net/eaton-approbationen/en/index.jsp shows the relevant approvals or permits for each component type. This therefore enables you to view the certificates provided or, depending on the test authority, also the product report. The information given is the same as what is provided in the databases of the authorities. Switchgear for USA and Canada Moeller® series www.eaton.com/moellerproducts Product selection for North American exports made easy Main Switch for USA and Canada Moeller® series www.eaton.com/moellerproducts Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS Motor Starters for USA and Canada Moeller® series Anyone wishing to avoid unfortunate experiences, should make use beforehand of the large number of publications that Eaton is offering on the issue of exports to North America. They contain the implementation of the codes & standards and a description of different practices. www.eaton.com/moellerproducts Special considerations governing the application of Manual Motor Controllers and Motor Starters in North America Switchgear and Systems Moeller® series Packag ing Machin e www.eaton.com/moellerproducts SAFETY GATE 4 OPEN Components and Systems for Global Markets Technical Paper Dipl.-Ing. Wolfgang Esser Technical Paper Dipl.-Ing. Wolfgang Esser Technical Paper Dipl.-Ing. Wolfgang Esser Second, supplemented edition 2010 VKF0211-563.indd 1 28.06.11 13:53 These technical articles can be accessed via http://www.moeller.net/en/company/news/publications/ index.jsp They can be downloaded or ordered free of charge. How to find the right contact: At Eaton, an efficient customer relationship management is standard practice. This guarantees you our support right from the start of any new project. Use these contact addresses to find your personal customer contact: In just a few steps we can direct you to specialist local support specifically for your business sector. Your customer contact in your region: Your customer contact worldwide: http://salesbonn.moeller.net www.eaton.eu/electrical/contact Service and consulting for UPS systems and hydraulic solutions. Further developing relations with our customers is particularly important to us. Your requirements and suggestions will be passed on promptly to the relevant specialists. After all, we take up the challenges you give us as if they were our own. Are your questions about uninterruptible power supplies (USPs)? Technical support If you have any questions about our products and for technical advice send an email to our support team: supportgermany@eaton.com or contact our telephone hotline at Tel.: +49 (0)7841 604 - 334 Service If you have a problem or a fault on one of our products contact us by email: servicegermany@eaton.com or contact us by phone at: Tel.: +49 (0)7841 604 - 334 We can be contacted here between Monday – Thursday from 08.00 – 17.00 CET and Friday from 08.00 – 16.00 CET. Are your questions about hydraulic solutions? Please contact the help desk of our Customer Service in Baden-Baden. This service will put you in touch with a customer contact in your locality. Our customer service: Eaton Hydraulics Group Dr.-Reckeweg-Straße 1 D-76532 Baden-Baden Tel.: +49 (0)7221 682 - 0 Fax: +49 (0)7221 682 - 788 Email: customersupportemea@eaton.com Eaton's After Sales Service This is the new name of Moeller‘s tried and trusted Field Service. Only the name has changed. The reliable and first-class service has stayed the same. Further information and general terms and conditions can be found at www.moeller.net/en/support/fieldservice/index.jsp. Hotline Service specialists Use our service personnel. Extensive know-how, combined with many years of experience and state-of-the-art equipment to help you find a solution for your tasks. Onsite service Free hotline for round-the-clock support. +49 (0)180 522 3822 (24/7) 0.12 euros per minute for calls from within the German Telecom network Repair and replacement service for Eaton devices. Material Components, assemblies and spare parts for the Eaton product range are available for your applications. Repairs Service products Eaton‘s After Sales Service offers the right service packages for your products. Online services Onsite service, analysis, conversions, expansions and maintenance. Downloads, FAQs and interactive troubleshooting 194 1/10 1/8 1/6 1/4 1/3 1/2 3/4 1 1-1/2 2 3 5 7-1/2 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 500 b)To 220 - 240 Va,b 110 - 120 V HP a)To Full-load motor-running currents in amperes corresponding to various AC horsepower ratings 360 - 380 V 440 - 480 V 550 - 600 V Single phase Two phase Three phase Single phase Two phase Three phase Single phase Three phase Single phase Two phase Three phase Single phase Two phase Three phase 3.0 3.8 4.4 5.8 7.2 9.8 13.8 16.0 20.0 24.0 34.0 56.0 80.0 100 135 - 4.0 4.8 6.4 9.0 11.8 16.6 26.4 38.0 48.0 72.0 94.0 118 138 180 226 - 4.4 6.4 8.4 12.0 13.6 19.2 30.4 44.0 56.0 84.0 108 136 160 208 260 - 1.5 1.9 2.2 2.9 3.6 4.9 6.9 8.0 10.0 12.0 17.0 28.0 40.0 50.0 68.0 88.0 110 136 176 216 - 2.0 2.4 3.2 4.5 5.9 8.3 13.2 19.0 24.0 36.0 47.0 59.0 69.0 90.0 113 133 166 218 - 2.2 3.2 4.2 6.0 6.8 9.6 15.2 22.0 28.0 42.0 54.0 68.0 80.0 104 130 154 192 248 312 360 480 602 - 1.0 1.2 1.4 1.8 2.3 3.2 4.5 5.1 6.4 7.7 10.9 17.9 27.0 33.0 44.0 56.0 70.0 87.0 112 139 - 1.3 1.8 2.3 3.3 4.3 6.1 9.7 14.0 18.0 27.0 34.0 44.0 51.0 66.0 83.0 103 128 165 208 240 320 403 482 560 636 786 2.5 3.5 4.0 5.0 6.0 8.5 14.0 21.0 26.0 34.0 44.0 55.0 68.0 88.0 108 - 1.0 1.2 1.6 2.3 3.0 4.2 6.6 9.0 12.0 18.0 23.0 29.0 35.0 45.0 56.0 67.0 83.0 109 135 156 208 - 1.1 1.6 2.1 3.0 3.4 4.8 7.6 11.0 14.0 21.0 27.0 34.0 40.0 52.0 65.0 77.0 96.0 124 156 180 240 302 361 414 477 590 2.0 2.8 3.2 4.0 4.8 6.8 11.2 16.0 20.0 27.0 35.0 44.0 54.0 70.0 86.0 - 0.8 1.0 1.3 1.8 2.4 3.3 5.3 8.0 10.0 14.0 19.0 24.0 28.0 36.0 45.0 53.0 66.0 87.0 108 125 167 - 0.9 1.3 1.7 2.4 2.7 3.9 6.1 9.0 11.0 17.0 22.0 27.0 32.0 41.0 52.0 62.0 77.0 99.0 125 144 192 242 289 336 382 472 obtain full-load currents for 200 and 208 V motors, increase corresponding 220 - 240 V ratings by 15 and 10 percent, respectively. obtain full-load currents for 265 and 277 V motors, decrease corresponding 220 - 240 V ratings by 13 and 17 percent, respectively. Quote from "Power Conversion Equipment - UL 508C, May 3, 2002". Reproduced from UL 508 C, Power Conversion Equipment, 3rd edition (May 2, 2002) with permission of Underwriters Laboratories Inc. CA04020001Z-EN-INT www.eaton.eu Full-load motor-running currents in amperes corresponding to various AC horsepower ratings 195 Minimum fuse sizes for short-circuit protection of three-phase motors The maximum value depends on the switching device or the overload relay. 230 V 400 V 440 V 500 V 690 V Motor Fuse rated opera- Starting tional Y/ current DOL Motor Fuse rated opera- Starting tional Y/ current DOL Motor Fuse rated opera- Starting tional Y/ current DOL Motor Fuse rated opera- Starting tional Y/ current DOL Motor Fuse rated opera- Starting tional Y/ current DOL (%) A A A A A A A A A A A A A A A kWh p.f. 0.06 0.7 58 0.37 2 – 0.21 2 – 0.19 2 – 0.17 2 – 0.12 2 – 0.09 0.7 60 0.54 2 – 0.31 2 – 0.28 2 – 0.25 2 – 0.18 2 – 0.12 0.7 60 0.72 4 2 0.41 2 – 0.37 2 – 0.33 2 – 0.24 2 – 0.18 0.7 62 1.04 4 2 0.6 2 – 0.54 2 – 0.48 2 – 0.35 2 – 0.25 0.7 62 1.4 4 2 0.8 4 2 0.76 2 – 0.7 2 – 0.5 2 – 0.37 0.72 66 2 6 4 1.1 4 2 1 4 2 0.9 2 2 0.7 2 – 0.55 0.75 69 2.7 10 4 1.5 4 2 1.4 4 2 1.2 4 2 0.9 4 2 0.75 0.79 74 3.2 10 4 1.9 6 4 1.7 4 2 1.5 4 2 1.1 4 2 1.1 0.81 74 4.6 10 6 2.6 6 4 2.4 4 2 2.1 6 4 1.5 4 2 1.5 0.81 74 6.3 16 10 3.6 6 4 3.3 6 4 2.9 6 4 2.1 6 4 2.2 0.81 78 8.7 20 10 5 10 6 4.6 10 6 4 10 4 2.9 10 4 3 0.82 80 11.5 25 16 6.6 16 10 6 16 10 5.3 16 6 3.8 10 4 4 0.82 83 14.8 32 16 8.5 20 10 7.7 16 10 6.8 16 10 4.9 16 6 5.5 0.82 86 19.6 32 25 11.3 25 16 10.2 20 10 9 20 16 6.5 16 10 7.5 0.82 87 26.4 50 32 15.2 32 16 13.8 25 16 12.1 25 16 8.8 20 10 11 0.84 87 38 80 40 21.7 40 25 19.8 32 25 17.4 32 20 12.6 25 16 15 0.84 88 51 100 63 29.3 63 32 26.6 50 32 23.4 50 25 17 32 20 18.5 0.84 88 63 125 80 36 63 40 32.8 63 32 28.9 50 32 20.9 32 25 22 0.84 92 71 125 80 41 80 50 37 80 40 33 63 32 23.8 50 25 30 0.85 92 96 200 100 55 100 63 50 100 63 44 80 50 32 63 32 37 0.86 92 117 200 125 68 125 80 61 125 80 54 100 63 39 80 50 45 0.86 93 141 250 160 81 160 100 74 125 100 65 125 80 47 80 63 55 0.86 93 173 250 200 99 200 125 90 125 100 79 160 80 58 100 63 75 0.86 94 233 315 250 134 200 160 122 160 125 107 200 125 78 160 100 90 0.86 94 279 400 315 161 250 200 146 200 160 129 200 160 93 160 100 110 0.86 94 342 500 400 196 315 200 179 250 200 157 250 160 114 200 125 132 0.87 95 401 630 500 231 400 250 210 250 250 184 250 200 134 250 160 160 0.87 95 486 630 630 279 400 315 254 315 250 224 315 250 162 250 200 200 0.87 95 607 800 630 349 500 400 318 400 315 279 400 315 202 315 250 250 0.87 95 – – – 437 630 500 397 630 400 349 500 400 253 400 315 315 0.87 96 – – – 544 800 630 495 630 630 436 630 500 316 500 400 400 0.88 96 – – – 683 1000 800 621 800 800 547 800 630 396 630 400 450 0.88 96 – – – 769 1000 800 699 800 800 615 800 630 446 630 630 500 0.88 97 – – – – – – – – – – – – 491 630 630 560 0.88 97 – – – – – – – – – – – – 550 800 630 630 0.88 97 – – – – – – – – – – – – 618 800 630 Instructions The rated motor currents apply to normal internally and surfacecooled three-phase motors with 1500 rpm. DOL starting: Starting current max. 6 × rated motor current. Starting time max. 5 s. Y/-start: Starting current max. 2 × motor rated current. Starting time max. 15 s. Set overload relay in line to 0.58 × motor rated current. Fuse ratings at Y/ starting apply also to three-phase slipring motors. For higher rated currents, starting currents and/or longer starting times, larger fuses will be required. Table applies for time delay and gL fuses (VDE 0636) For LV h.b.c. fuse with aM characteristics the fuse should be equal to the rated operational current. CA04020001Z-EN-INT www.eaton.eu Appendix Motor power 196 Motor lore Drives egineering selection criteria Each drive task requires a drive motor. The speed, torque and controllability of each motor must fulfill the requirements of the task. The following generally applies: the application determines the drive. The drive motor most frequently used worldwide in industrial plants and large buildings is the 3-phase asynchronous motor. Its robust and simple construction as well as its high degrees of protection and standard types are the main features of this inexpensive electric motor. Motor connection V1 W1 W2 U2 V2 Star circuit L1 U1 L2 V2 L3 W3 L1 U1 L2 V2 L3 △/ 14.5 / 8.5 A 1410 min-1 IP 54 L1 ILN ULN S1 L3 L1 ILN W1 W2 U LN = 3 U W , LN = I W The electrical and mechanical rating data of the motor must be stated on its rating plate (IEC 34-1, VDE 0530). The data on the rating plate describes the stationary operation of the motor in the area of its operating point (MN, e.g. at 400 V and 50 Hz). The operational data is unstable in the motor start phase. The following examples show the rating plates for two motors with a motor shaft output of 4 kW and the respective connection circuits on a 3-phase AC network with 400 V and 50 Hz. U1 V1 W1 U1 V1 W1 W2 U2 V2 W2 U2 V2 • With the specified 230/400 V voltage, this motor must be connected to the 3-phase system (ULN = 400 V) in a star-connected circuit. • The voltage of each motor winding is designed for 230 V. The windings must therefore be connected in sequence to the phase voltage (400 V). • The three winding phases (W2-U2-V2) are configured in the terminal box to the so-called star point. The voltage of the individual phases to the star point is 230 V (= UW). The following figure shows the characteristic startup curves of a 3-phase asynchronous motor. L 360° 120° 120° On the three-phase asynchronous motor, three windings are arranged offset from each other by 120°/p (p = number of pole pairs). To generate a rotating field in the motor, an alternating voltage is applied to each phase in turn at a time delay of 120 °. MS f n: p s: CA04020001Z-EN-INT www.eaton.eu ML nN nS n IA: Starting current IN: Rated operational current at the operating point MA: Starting torque MB: Accelerating torque (MM > ML) MK: Breakdown torque ML: Load torque MM: Motor torque MN: Rated load torque, (stable operating point, intersection point of the 3-phase speed torque characteristic with the load characteristic) MS: Pull-up torque n: Speed (actual value) nN: Rated speed at the operating point nS: Synchronous speed (nS - nN = slip speed s) Synchronous speed: f n s = --p Slip speed in %: • The three winding phases (U1 – W2, V1 – U2, W1 – V2) are combined in the terminal box and connected directly to the individual phases. f n = --- 1 – s p MK 0 • With the specified 400/690 V voltage, this motor must be connected to the 3-phase system (ULN = 400 V) in a delta circuit. • Each motor winding is designed here for the maximum phase voltage of 400 V and can be connected directly. 3-phase asynchronous motor speed: IN 270° 120° 3 IW ns – n s = -------------- 100% ns Startup characteristics Regardless of the circuit type and the type of three-phase asynchronous motor, the connections must be labeled, so that their alphabetical sequence (e.g. U1, V1, W1) corresponds with the order of the mains voltage phase sequence (L1, L2, L3) and causes the motor to rotate clockwise. 180° V2 W1 U LN = U W , LN = MB 90° V1 W2 MM 0 L3 U1 MN L3 L2 U2 V2 U1 M, I I A MA L2 ULN U2 50 Hz Iso. KI F Information on the rating plate The rotation direction of a motor is always determined by directly looking at the drive shaft of the motor (from the drive end). On motors with two shaft ends, the driving end is denoted with D (= Drive), the non-driving end with N (= No drive). L1 1410 min-1 IP 54 V1 8.5 / 4.9 A cos ϕ 0.82 4.0 KW 50 Hz Iso. KI F L2 △/ 400 / 690 V cos ϕ 0.82 4.0 KW W3 REV = reverse run (anticlockwise rotation field) Delta circuit 230 / 400 V S1 Clockwise Anticlockwise operation (FWD) (REV) FWD = forward run (clockwise rotation field) When connecting a 3-phase motor to the mains supply, the data on the rating plate of the motor must correspond to the mains voltage and frequency. The standard connection is implemented via six screw terminals in the terminal box of the motor and with two types of circuit, the star connection and the delta circuit, depending on the mains voltage. U1 The effect of inductance causes the rotation field and torque to be formed in the rotor winding. The speed of the motor thus depends on the number of pole pairs and the frequency of the supply voltage. The operating direction can be reversed by swapping over two of the supply phases. Frequency of voltage in Hz (= s-1) Speed in r.p.m. Number of pole pairs Slip speed in r.p.m. Electric power: P 1 = U I 3 cos P1: Electrical power in W U: Rated operating voltage in V I: Rated operational current in A cos ?: Power factor Motor output (power equation): MN n P 2 = ---------------9550 P2: Mechanical shaft output power in kW MN: Rated torque in Nm n: Speed in r.p.m. Efficiency: P = ----2P1 Eaton Online Catalog – find product details quickly and efficiently! You can find comprehensive up-to-date product information at http://ecat.moeller.net Lookup You can search by keywords, product names, article numbers, technical data: The search understands everything and takes you straight to the product you’re looking for. Graphical navigation Graphical representation of the fields of application and product groups. Selection aids Tailored to the typical expert’s approach, this search aid helps you quickly find the product you need. HTML data sheet; can be saved as PDF file. Data sheets For every article the catalog can generate a technical data sheet, which you can convert to a PDF file for printing or saving with a single click. Parts lists From your search results you can create a parts list that you can then send to your Eaton sales partner as a query. Parts list, e.g. for queries to Eaton Sales. The power of fusion. You can find comprehensive up-to-date information about Eaton’s automation products and switchgear in our Online Catalog. 1833 1874 1886 1893 1897 1899 1906 1908 1911 1914 1934 1961 1962 1963 1967 1977 1983 1984 1989 There’s a certain energy at Eaton. It’s the power of uniting some of the world’s most respected names to build a brand you can trust to meet your every power management need. Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it’s needed most. Building on over 100 years of experience in electrical power management, the experts at Eaton deliver customized, integrated solutions to solve your most critical challenges. To learn more visit www.eaton.eu/electrical. All of the above are trademarks of Eaton or its affiliates. Eaton has a license to use the Westinghouse brand name in Asia Pacific. ©2013 Eaton. CA04020001Z-EN-INT_Umschlag.indd 7-9 09.07.13 13:20 DC1/DA1 and SVX/SPX variable frequency drives DS7 and S801+/S811+ soft starters Rapid Link 4.0 distributed, electronic drive system Product range catalog for variable frequency drives, soft starters, Rapid Link Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it’s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers’ most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit www.eaton.eu. To contact an Eaton salesperson or local distributor/agent, please visit www.eaton.eu/electrical/customersupport Product range catalog Efficient Engineering for starting and controlling motors. Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton internet pages and Eaton order confirmations. Eaton Industries GmbH Hein-Moeller-Str. 7–11 D-53115 Bonn / Germany © 2012 by Eaton Corporation All rights reserved Printed in Germany 07/13 Publication No.: CA04020001Z_EN-INT Doku/DHW/ip/MP 07/13 Article No.: 170504 CA04020001Z-EN-INT_Umschlag.indd 4-6 Eaton is a registered trademark of Eaton Corporation All other trademarks are property of their respective owners. SmartWire-DT® is a registered trademark of Eaton Corporation. 09.07.13 13:19
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Print high-res Author : Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Deutschland/Germany Create Date : 2013:07:23 13:50:37Z Keywords : "PowerXL variable frequency drives, frequency inverter, DC1, DA1, 9000X, SVX, SPX, Soft starters, DS7, S801+, S811+, distributed, electronic drive system Rapid Link, Drives, Power Drives System, PDS, Motor lore, SmartWire DT" Modify Date : 2013:07:24 11:20:05+02:00 Has XFA : No Language : en XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Title : Product range catalog CA04020001Z-EN Creator : Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Deutschland/Germany Description : Efficient Engineering for starting and control motors Subject : PowerXL variable frequency drives, frequency inverter, DC1, DA1, 9000X, SVX, SPX, Soft starters, DS7, S801+, S811+, distributed, electronic drive system Rapid Link, Drives, Power Drives System, PDS, Motor lore, SmartWire DT Creator Tool : FrameMaker 10.0.2 Metadata Date : 2013:07:24 11:20:05+02:00 Producer : Acrobat Distiller 10.1.5 (Windows) Document ID : uuid:973d7943-8da8-462f-93d3-6beaf753cb83 Instance ID : uuid:3ba59a4c-ec4f-4646-b683-927307e37f15 Page Layout : SinglePage Page Mode : UseOutlines Page Count : 177EXIF Metadata provided by EXIF.tools