DC1/DA1 and SVX/SPX variable frequency drives
DS7 and S801+/S811+ soft starters
Rapid Link 4.0 distributed, electronic drive system
Product range catalog for variable frequency drives, soft starters, Rapid Link

Eaton is dedicated to ensuring that reliable, efficient and safe
power is available when it’s needed most. With unparalleled
knowledge of electrical power management across industries,
experts at Eaton deliver customized, integrated solutions to
solve our customers’ most critical challenges.
Our focus is on delivering the right solution for the application.
But, decision makers demand more than just innovative products.
They turn to Eaton for an unwavering commitment to personal
support that makes customer success a top priority. For more
information, visit www.eaton.eu.
To contact an Eaton salesperson or
local distributor/agent, please visit
www.eaton.eu/electrical/customersupport

Product range catalog
Efficient Engineering for
starting and controlling motors.

Changes to the products, to the information contained in this document, and to prices
are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to
Trademarks (especially Eaton, Moeller, Cutler-Hammer). The Terms and Conditions of Eaton
apply, as referenced on Eaton internet pages and Eaton order confirmations.

Eaton Industries GmbH
Hein-Moeller-Str. 7–11
D-53115 Bonn / Germany
© 2012 by Eaton Corporation
All rights reserved
Printed in Germany 07/13
Publication No.: CA04020001Z_EN-INT
Doku/DHW/ip/MP 07/13
Article No.: 170504

CA04020001Z-EN-INT_Umschlag.indd 4-6

Eaton is a registered trademark of Eaton
Corporation
All other trademarks are property of their
respective owners.
SmartWire-DT® is a registered trademark of
Eaton Corporation.

09.07.13 13:19

Eaton Online Catalog – find product
details quickly and efficiently!
You can find comprehensive up-to-date product information at http://ecat.moeller.net

Lookup
You can search by keywords, product names, article numbers,
technical data: The search understands everything and takes
you straight to the product you’re looking for.

Graphical navigation
Graphical representation of the fields of application and
product groups.

Selection aids
Tailored to the typical expert’s approach, this search aid helps
you quickly find the product you need.

HTML data sheet; can be saved as PDF file.

Data sheets
For every article the catalog can generate a technical data
sheet, which you can convert to a PDF file for printing or
saving with a single click.

Parts lists
From your search results you can create a parts list that you
can then send to your Eaton sales partner as a query.

Parts list, e.g. for queries to Eaton Sales.

The power of fusion.

You can find comprehensive up-to-date
information about Eaton’s automation
products and switchgear in our Online
Catalog.

1833

1874

1886

1893

1897

1899

1906

1908

1911

1914

1934

1961

1962

1963

1967

1977

1983

1984

1989

There’s a certain energy at Eaton. It’s the power of uniting some of the
world’s most respected names to build a brand you can trust to meet
your every power management need.
Eaton is dedicated to ensuring that reliable, efficient and safe power
is available when it’s needed most. Building on over 100 years of
experience in electrical power management, the experts at Eaton
deliver customized, integrated solutions to solve your most critical
challenges. To learn more visit www.eaton.eu/electrical.

All of the above are trademarks of Eaton or its affiliates.  Eaton has a license to use the
Westinghouse brand name in Asia Pacific. ©2013 Eaton.

CA04020001Z-EN-INT_Umschlag.indd 7-9

09.07.13 13:20

Page 78

Page 104

S801+, S811+ soft starters

Page 132

Rapid Link distributed, electronic drive system

Page 152

SmartWire-DT™ communication system

Page 178

Appendix

Page 189

DC1, DA1 variable frequency
drives
Appendix

SmartWire-DT™

Rapid Link

DS7 soft starters

SVX, SPX variable frequency
drives

9000X variable frequency drives: SVX, SPX

Page 4

DS7 soft starters

PowerXL™ DC1, DA1 variable frequency drives

S801+, S811+ soft starters

Table of contents

Energizing a world
that demands more.

Discover today’s Eaton.
Powering business worldwide
As a global diversified power management company,
we help customers worldwide manage the power
needed for buildings, aircraft, trucks, cars, machinery
and businesses.
Eaton’s innovative technologies help customers manage
electrical, hydraulic and mechanical power more reliably,
efficiently, safely and sustainably.

We provide integrated
solutions that help make
energy, in all its forms,

We deliver:
s

more practical and

Electrical solutions that use less energy, improve power reliability
and make the places we live and work safer and more comfortable

s

Hydraulic and electrical solutions that enable machines
to deliver more productivity without wasting power

s

accessible.
With 2012 sales of
$16.3 billion, Eaton
has approximately
103,000 employees

Aerospace solutions that make aircraft lighter, safer and less

around the world and

costly to operate, and help airports operate more efficiently

sells products in more
than 175 countries.

s

Vehicle drivetrain and powertrain solutions that deliver
more power to cars, trucks and buses, while reducing fuel consumption
and emissions

Eaton’s electrical business
Eaton is a global leader with expertise in:

%ATONISPOSITIONEDTHROUGHITSGLOBALSOLUTIONSTOANSWER
TODAYSMOSTCRITICALELECTRICALPOWERMANAGEMENTCHALLENGES
7ITHYEARSOFELECTRICALEXPERIENCEBEHINDUSWERE
ENERGIZEDBYTHECHALLENGEOFPOWERINGUPAWORLDTHAT
DEMANDSTWICEASMUCHENERGYASTODAY7EREANTICIPATING
NEEDSENGINEERINGPRODUCTSANDCREATINGSOLUTIONSTO
ENERGIZEOURMARKETSTODAYANDINTHEFUTURE

s

0OWERDISTRIBUTIONANDCIRCUITPROTECTION

s

"ACKUPPOWERPROTECTION

s

3OLUTIONSFORHARSHANDHAZARDOUSENVIRONMENTS

s

,IGHTINGANDSECURITY

s

3TRUCTURALSOLUTIONSANDWIRINGDEVICES

s

#ONTROLANDAUTOMATION

7EAREDEDICATEDTOENSURINGTHATRELIABLEEFFICIENTANDSAFE
POWERISAVAILABLEWHENITSNEEDEDMOST

s

%NGINEERINGSERVICES

www.eaton.eu

PowerXL™ DC1, DA1 variable frequency
drives
Variable frequency drives make it possible to use infinitely variable speed control with
three-phase asynchronous motors and AC motors. To do so, they convert a single-phase
or three-phase alternating voltage with a specific frequency and amplitudes into a singlephase or three-phase alternating voltage with a variable frequency and a variable amplitude. With its DC1 and DA1 device series, Eaton has just the right variable frequency
drive for any machine building application or standard electric drive system application,
regardless of whether your needs are extremely simple or extremely complex.
DC1 variable frequency drives
Output voltage with sinusoidal pulse-width modulation (PWM) when using Volts-per-Hertz control (V/Hz control) with slip compensation and start voltage boost.
DC1-12…: UIN 1~230 V/UOUT 3~230 V, allocated motor output 0.37 – 4 kW
DC1-32…: UIN 3~230 V/UOUT 3~230 V, allocated motor output 0.37 – 4 kW
DC1-34…: UIN 3~400 V/UOUT 3~400 V, allocated motor output 0.75 – 11 kW
DC1-S2…: UIN 1~230 V/UOUT 1~230 V, allocated motor output 0.37 – 1.1 kW (Single-phase
motor)
DC1-S1…: UIN 1~115 V/UOUT 1~115 V, allocated motor output 0.37 – 0.55 kW
DC1-1D…: UIN 1~115 V/UOUT 3~230 V, allocated motor output 0.37 – 1.1 kW (voltage doubler)
DA1 variable frequency drives
Output voltage with sinusoidal pulse-width modulation (PWM) when using Volts-per-Hertz control (V/Hz control), sensorless (SLVC) and sensored vector control
DA1-12…: UIN 1~230 V/UOUT 3~230 V, allocated motor output 0.75 – 2.2 kW
DA1-32…: UIN 3~230 V/UOUT 3~230 V, allocated motor output 0.75 – 75 kW
DA1-34…: UIN 3~400 V/UOUT 3~400 V, allocated motor output 0.75 – 250 kW

5

System overview
variable frequency drives DC1

6

Description
variable frequency drives DC1

7

System overview
variable frequency drives DA1

8

Description
variable frequency drives DA1

9

Technical overview
variable frequency drives DC1, DA1

10

Key to type references, Sizes and degree of protection UL/CSA
variable frequency drives DC1

11

Ordering
variable frequency drives DC1

14

Key to type references UL/CSA
variable frequency drives DA1

18

Sizes and degree of protection
variable frequency drives DA1

19

Ordering
variable frequency drives DA1

20

Accessories

31

Braking resistances

34

Mains choke, motor chokes

36

Engineering
Assigned switching and protective elements

39

General information on Engineering

40

Connection example for DC1

42

Assigned switching and protective elements

44

Technical data
variable frequency drives DC1

48

variable frequency drives DA1

54

Mains choke, motor chokes

62

Dimensions
variable frequency drives DC1

64

variable frequency drives DA1

65

Accessories

68

Mains choke, motor chokes

70

Sine filters

72

Braking resistances

74

CA04020001Z-EN-INT

www.eaton.eu

DC1, DA1

PowerXL™ variable frequency drives

6

PowerXL™ variable frequency drives
DC1

System overview
DC1

DC1 with IP20 degree of protection

1

7

2

6

3

5
4

DC1 variable frequency drive

1

→ page 12

Mains choke, motor choke, sine filter

2

→ page 36, → page 37
3

Braking resistance
→ page 34

Expansion modules

4

→ page 33
5

SmartWire-DT module
→ page 33

Bluetooth communications stick

6

→ page 31

External Keypad

7

→ page 31

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

7

DC1

Description
DC1, DA1

DC1

The DC1 is Eaton's compact variable frequency drive. It has been specifically
designed for simple applications. With only 14 basic parameters and
outstanding ease of mounting and installation, the DC1 is perfect for quick
commissioning. This makes these compact variable frequency drive ideal for
series production applications in the field of machine building.
Typical applications for this series include fans, pumps, and conveyor
systems. In addition, additional parameters and functionalities can be flexibly
enabled in order to allow the DC1 to handle more demanding applications as
well.
When configured with an IP66 degree of protection, DC1 variable frequency
drives can be installed in humid and wet locations as well.
In addition, these variable frequency drives can also be used as stand-alone
units directly on site if they are equipped with a setpoint potentiometer, a
selector switch, and a mains transfer switch and are configured with an IP66
degree of protection.

Essential features

Accessory consideration

• Fast commissioning with 14 basic parameters
• Performance range (allocated motor output)
– 0.37 - 4 kW (UIN: 1~ 230 V / UOUT: 3~ 230 V)
– 0.37 - 4 kW (UIN: 3~ 230 V / UOUT: 3~ 230 V)
– 0.75 - 11 kW (UIN: 3~ 400 V / UOUT: 3~ 400 V), up to 7.5 kW at IP66
– 0.37 - 1.1 kW (UIN: 1~230 V / UOUT: 1~230 V), single-phase motor
– 0.37 - 0.55 kW (UIN: 1~ 115 V / UOUT: 1~ 115 V), single-phase motor
– 0.37 - 1.1 kW (UIN: 1~ 115 V / UOUT: 3~ 230 V) with voltage doubler
• Large overload capability: 150% for 60 seconds, 175% for 2 seconds
• Maximum ambient temperature:
50 °C without derating (IP20) / 40 °C (IP66)
• Integrated® CANopen and Modbus
• Degree of protection to IP20 and IP66
• EMC filter
• Optional internal braking transistor for IP20 degree of protection
• Integrated PI controller
• V/Hz control with start voltage boost and slip compensation
• International standards (CE, UL, cUL, C-Tick, UkrSEPRO, RoHS)
• Side-by-side mounting

•
•
•
•
•
•
•

SmartWire-DT field bus module
I/O expansion with plug-in modules
External keypad for control panel door
Mains choke
Motor choke
sine filter
braking resistances

CA04020001Z-EN-INT

www.eaton.eu

8

PowerXL™ variable frequency drives
DA1

System overview
DA1

DA1 with IP20 degree of protection

1

2

6

5
3

4

DA1 variable frequency drives

1

→ page 20

Mains choke, motor choke, sine filter

2

→ page 36, → page 37
3

Braking resistance
→ page 34

4

Fieldbus modules
→ page 33

Bluetooth communications stick

5

→ page 31
6

External Keypad
→ page 31

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

9

DA1

Description
DC1, DA1

DA1

DA1 frequency inverters are ideal for demanding, speed-dependent
applications. Their wide performance range of up to 250 kW, together with
their compact dimensions and high level of functionality, are sure to leave a
lasting impression. Accordingly, DA1 units come with an integrated EMC filter
and braking transistor. Moreover, the Modbus RTU and CANopen protocols
are integrated as standard.®. With sensorless vector control, DA1 variable
frequency drives are able to provide 200% torque at zero rpm. This makes them
the perfect choice for applications that involve lifting or tractive forces.
Comprehensive expansions such as additional inputs and outputs (analog,
digital) and various field bus modules round off this variable frequency drive's
flexibility.
When configured with an IP66 degree of protection, DA1 variable frequency
drives can be installed in humid and wet locations as well.
In addition, these variable frequency drives can also be used as stand-alone
units directly on site if they are equipped with a setpoint potentiometer,
a selector switch, and a mains transfer switch.

Essential features

Accessory consideration

• Performance range:
– 0.75 - 2.2 kW (UIN: 1~ 230 V / UOUT: 3~ 230 V)
– 0.75 - 75 kW (UIN: 3~ 230 V / UOUT: 3~ 230 V)
– 0.75 - 250 kW (UIN: 3~ 400 V / UOUT: 3~ 400 V)
• Large overload capability: 150% for 60 seconds, 200% for 4 seconds
• Degrees of protection
– IP20 to 11 kW at 400 V
– IP40 at 200/250 kW at 400 V
– IP55 for 11 to 160 kW with 400 V
– IP66 up to 7.5 kW with 400 V; 0.75–4 kW with 230 V
• The maximum allocated motor output is 7.5 kW with degree of protection
IP66.
• Integrated® CANopen and Modbus
• EMC filter, integrated
• Braking transistor, integrated
• Control method: V/Hz control, sensorless vector control, vector control with
encoder
• Safe Torque Off (STO)
• Can be used to drive high-efficiency PM motors
• International standards (CE, UL, cUL, C-Tick, UkrSEPRO, RoHS)
• Side-by-side mounting
• Ambient air temperature 50 °C without derating (IP20), max. 40 °C (IP66)
• Master/Slave functionality

• SmartWire-DT field bus module
• Field bus modules (PROFIBUS, PROFINET, Ethernet/IP, EtherCat,
Modbus TCP, BACnet, and DeviceNet)
• I/O expansion with plug-in modules
• External keypad for control panel door
• High-resolution OLED display
• Mains choke
• Motor chokes
• sine filter
• braking resistances

CA04020001Z-EN-INT

www.eaton.eu

10

PowerXL™ variable frequency drives
DC1, DA1

Technical overview
DC1, DA1

DC1...

DA1...

115 V AC, single-phase

✓

-

230 V AC, 1-phase

✓

✓

230 V AC, 3-phase

✓

✓

400 V AC, 3-phase

✓

✓

Rated operational voltage

Ue

Supply frequency

fLN

Hz

50/60

50/60

Rated operational current

Ie

A

2.3 - 24

2.2 - 450

Overload current for 60 s every 600 s

IL

%

150

150

Starting current for 2 s

IL

%

175

-

Starting current for 4 s

IL

%

-

200

Assigned motor rating
at 115 V, 50 Hz

P

kW

0.37 - 0.55 (Single-phase motors)

-

at 230 V, 50 Hz

P

kW

0.37 - 4 (0.37 - 4 for single-phase motors)

0.75 - 75

at 400 V, 50 Hz

P

kW

0.75 - 11

0.75 - 250

IP20/NEMA 0

-10 - +50

-10 - +50

IP40

-

-10 - +30

IP55/NEMA 3

-

-10 - +40 / -10 - +30 (Ie > 180 A)

IP66/NEMA 4X

-10 - +40

-10 - +40

-40 - +60

-40 - +60

Ambient temperature
Operation

°C

Storage

°C

Operation Mode
U/f control

✓

✓

Slip compensation

✓

✓

sensorless vector control (SLV)

-

✓

Vector control with feedback (CLV)

-

✓

4 - 32

4 - 32

Switching frequency

fPWM

Output voltage with Ve

U2

kHz

115 V AC, single-phase

✓

-

230 V AC, single-phase

✓

-

230 V AC, 3-phase

✓

✓

400 V AC, 3-phase

✓

✓

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

Output Frequency

f2

Hz

Protection type
IP20/NEMA 0

✓

✓

IP40

-

✓

IP55/NEMA 3

-

✓

IP66/NEMA 4X

✓

✓

Fitted with
Radio interference suppression filter

✓

✓

Brake chopper

✓

✓

Additional PCB protection

-

✓

7-digital display assembly

✓

✓

OLED display

-

✓

Interface

OP-Bus (RS485)/Modbus RTU, CANopen®

OP-Bus (RS485)/Modbus RTU, CANopen®

Fieldbus connection

SmartWire-DT

Analog inputs

parameterizable, max. 2 x (0 - 10 V, 0/4 - 20 mA)

Ethernet IP
DeviceNet
PROFIBUS
PROFINET
Modbus-TCP
EtherCAT
BACnet/IP
SmartWire-DT
parameterizable, max. 2 x (0 - 10 V, 0/4 - 20 mA)

Analog outputs

parameterizable, max. 1 x (0 - 10 V)

parameterizable, max. 2 x (0 - 10 V, 0/4 - 20 mA)

Digital inputs

parameterizable, max. 4 x (max. 30 V DC)

parameterizable, 3 x (max. 30 V DC)

Digital outputs

parameterizable, max. 1 x (24 V DC)

parameterizable, max. 2 x (24 V DC)

Relay outputs
Production quality

parameterizable, 1 x N/O, 6 A (250 V AC) / 5 A
(30 V DC)
RoHS, ISO 9001

parameterizable, 1 x N/O and 1 x changeover
contact, 6 A (250 V AC) / 5 A (30 V DC)
RoHS, ISO 9001

Safety functions

-

STO (Safe Torque Off)

Standards

EMC: EN 61800-3:2004+A1-2012

EMC: EN 61800-3:2004+A1-2012

Certifications

CE, cUL, UL, c-Tick, Ukr Sepro

CE, cUL, UL, c-Tick, Ukr Sepro

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

11

DC1

Key to type references
DC1, DA1

DC1

DC1 - 1 2 4D1 F N - A 20 N
Device series

Type

DC1 = variable frequency drive, compact, series 1
(D = Drives, C = Compact, 1 = Series 1)

N = Standard basic device
Degree of protection

Connection in power section

20 = IP20/NEMA 0
66 = IP66/NEMA 4X
6S = IP66 with switch/NEMA 4X, switched

1 = single-phase mains connection/
three-phase motor connection
3 = three-phase mains connection/
three-phase motor connection
S = single-phase mains connection/
single-phase motor connection

Display unit (display)
A = LED display

Mains voltage category
1 = 110 V (110 - 115 V ± 10 %)
2 = 230 V (200 - 240 V ± 10 %)
4 = 400 V (380 - 480 V ± 10 %)
D = 110 V input/230 V output
(voltage doubler)

B = Brake chopper
N = no internal brake chopper
B = Brake chopper
EMC (radio interference suppression filter)

Rated operational current (examples)

N = no internal RFI filter
F = Internal RFI filter

2D2 = 2,2 A
4D1 = 4,1 A
024 = 24 A

Sizes and degree of protection
DC1

Frame size

UL/CSA

Protection type
IP20/NEMA 0

Information relevant for export to North America
IP66/NEMA 4X

IP66/NEMA 4X
Local controls

FS1

Product Standards
⏚

L1/L L2/N
L3

UL File No.
UL Category Control No.
CSA File No.

0

REV

FWD

OFF

PWR

ON

1

2

3

4

5

6

7

⏚

8

CSA Class No.
North America
Certification

9 10 11

U

V

W

Suitable for
Max. Voltage Rating

FS2
⏚

DC- L1/L L2/N
L3

REV

0
FWD

PWR

OFF

ON

1

⏚

2

3

4

5

6

DC+ BR

7

8

U

UL 508C; CSA-C22.2 No. 14;
IEC/EN61800-3; IEC/EN61800-5;
CE marking
E172143
NMMS, NMMS7
UL report applies to both US
and Canada
3211-06
UL listed, certified by UL for use
in Canada
Branch circuits
1~ 120 V AC IEC: TN-S UL/CSA:
"Y" (Solidly Grounded Wey)
1~ 240 V AC IEC: TN-S UL/CSA:
"Y" (Solidly Grounded Wey)
3~ 240 V AC IEC: TN-S UL/CSA:
"Y" (Solidly Grounded Wey)
3~ 480 V AC IEC: TN-S UL/CSA:
"Y" (Solidly Grounded Wey)

9 10 11

V

W

FS3
⏚

DC- L1/L L2/N
L3

REV

0
FWD

PWR

OFF

ON

1

⏚

DC+ BR

2

3

4

5

U

6

7

V

8

9 10 11

W

CA04020001Z-EN-INT

www.eaton.eu

12

PowerXL™ variable frequency drives
DC1, for AC motors 115 V/230 V

Ordering
Rated motor
current

Fitted with

P

Ie

A

kW

A

Mains voltage (50/60Hz) ULN 110 (-10%) - 115 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
7
0.37
7
-

-

✓

-

-

-

✓

-

-

-

✓

✓

-

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

-

✓

-

-

-

✓

-

-

-

✓

✓

✓

-

✓

-

✓

-

✓

✓

-

-

✓

-

✓

-

✓

-

-

-

✓

-

-

-

✓

✓

✓

-

✓

-

✓

-

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

Brake chopper

Local controls

Assigned motor
rating 2)

7-digital display
assembly

Rated
operational
current1)
Ie

Radio interference
suppression filter

DC1, for AC motors 115 V/230 V

Frame size

Protection type

Part no.
Article no.

FS1

IP20/NEMA 0

DC1-S17D0NN-A20N
169497
DC1-S17D0NN-A66N
169498
DC1-S17D0NN-A6SN
169499

Price
see price
list

Std. pack

Ue 115 V AC, single-phase / U2 115 V AC, single-phase

10.5

0.55

10.5

IP66/NEMA 4X

FS2

IP20/NEMA 0
IP66/NEMA 4X

1 off

DC1-S1011NB-A20N
169500
DC1-S1011NB-A66N
169501
DC1-S1011NB-A6SN
169502

Ue 230 V AC, 1-phase / U2 230 V AC, single-phase
Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
4.3
0.37
4.3
-

7

10.5

Notes

0.75

7

1.1

10.5

1) Rated

FS1

FS2

IP20/NEMA 0

DC1-S24D3NN-A20N
169512
DC1-S24D3FN-A20N
169521

IP66/NEMA 4X

DC1-S24D3NN-A66N
169513
DC1-S24D3NN-A6SN
169514
DC1-S24D3FN-A66N
169522
DC1-S24D3FN-A6SN
169523

IP20/NEMA 0

DC1-S27D0NN-A20N
169515
DC1-S27D0FN-A20N
169524

IP66/NEMA 4X

DC1-S27D0NN-A66N
169516
DC1-S27D0NN-A6SN
169517
DC1-S27D0FN-A66N
169525
DC1-S27D0FN-A6SN
169526

IP20/NEMA 0

DC1-S2011NB-A20N
169518
DC1-S2011FB-A20N
169527

IP66/NEMA 4X

DC1-S2011NB-A66N
169519
DC1-S2011NB-A6SN
169520
DC1-S2011FB-A66N
169528
DC1-S2011FB-A6SN
169529

1 off

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C

2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or

1800 rpm (at 60 Hz)
Information relevant for export to North America → page 11

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

13

DC1, for three-phase motors 230 V

P

Ie

A

kW

A

Frame size

Protection type

Part no.
Article no.

FS1

IP20/NEMA 0

DC1-1D2D3NN-A20N
169503
DC1-1D2D3NN-A66N
169504
DC1-1D2D3NN-A6SN
169505

Mains voltage (50/60Hz) ULN 110 (-10%) - 115 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
2.3
0.37
2
-

-

✓

-

-

-

✓

-

-

-

✓

✓

-

-

✓

-

IP20/NEMA 0

-

-

✓

-

IP66/NEMA 4X

-

-

✓

✓

-

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

-

✓

-

-

-

✓

-

-

-

✓

✓

✓

-

✓

-

✓

-

✓

✓

-

-

✓

-

✓

-

✓

-

-

-

✓

-

-

-

✓

✓

✓

-

✓

-

✓

-

✓

✓

Price
see price
list

Std. pack

DC1, DA1

Fitted with

Local controls

Rated motor
current

7-digital display
assembly

Assigned motor
rating 2)

Brake chopper

Rated
operational
current1)
Ie

Radio interference
suppression filter

DC1, for three-phase motors 230 V

Ue 115 V AC, single-phase / U2 230 V AC, 3-phase

4.3

5.8

0.75

1.1

3.2

4.6

IP66/NEMA 4X

FS2

IP20/NEMA 0
IP66/NEMA 4X

1 off

DC1-1D4D3NN-A20N
169506
DC1-1D4D3NN-A66N
169507
DC1-1D4D3NN-A6SN
169508
DC1-1D5D8NB-A20N
169509
DC1-1D5D8NB-A66N
169510
DC1-1D5D8NB-A6SN
169511

Ue 230 V AC, 1-phase / U2 230 V AC, 3-phase
Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
2.3
0.37
2
-

4.3

Notes

0.75

1) Rated

3.2

FS1

FS1

IP20/NEMA 0

DC1-122D3NN-A20N
169222
DC1-122D3FN-A20N
169240

IP66/NEMA 4X

DC1-122D3NN-A66N
169223
DC1-122D3NN-A6SN
169224
DC1-122D3FN-A66N
169241
DC1-122D3FN-A6SN
169242

IP20/NEMA 0

DC1-124D3NN-A20N
169225
DC1-124D3FN-A20N
169243

IP66/NEMA 4X

DC1-124D3NN-A66N
169226
DC1-124D3NN-A6SN
169227
DC1-124D3FN-A66N
169244
DC1-124D3FN-A6SN
169245

1 off

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C

2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or

1800 rpm (at 60 Hz)
Information relevant for export to North America → page 11

CA04020001Z-EN-INT

www.eaton.eu

14

PowerXL™ variable frequency drives

Fitted with

P

Ie

A

kW

A

Local controls

Rated motor
current

7-digital display
assembly

Assigned motor
rating 2)

Brake chopper

Rated
operational
current1)
Ie

Radio interference
suppression filter

DC1, for three-phase motors 230 V

-

✓

-

✓

-

✓

-

-

✓

✓

-

✓

✓

✓

-

-

-

✓

-

-

-

✓

✓

✓

-

✓

-

✓

-

✓

✓

-

✓

✓

-

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

Frame size

Protection type

Part no.
Article no.

FS1

IP20/NEMA 0

DC1-127D0NN-A20N
169228
DC1-127D0FN-A20N
169246

Price
see price
list

Std. pack

Ue 230 V AC, 1-phase / U2 230 V AC, 3-phase
Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
7
1.5
6.3
-

10.5

15

Notes

2.2

8.7

4

14.8

1) Rated

DC1-127D0NB-A20N
169231
DC1-127D0FB-A20N
169249

FS2

FS1

IP66/NEMA 4X

FS3

DC1-127D0NN-A66N
169229
DC1-127D0NN-A6SN
169230
DC1-127D0FN-A66N
169247
DC1-127D0FN-A6SN
169248
DC1-127D0NB-A66N
169232
DC1-127D0NB-A6SN
169233
DC1-127D0FB-A66N
169250
DC1-127D0FB-A6SN
169251

FS2

FS2

1 off

IP20/NEMA 0

DC1-12011NB-A20N
169234
DC1-12011FB-A20N
169252

IP66/NEMA 4X

DC1-12011NB-A66N
169235
DC1-12011NB-A6SN
169236
DC1-12011FB-A66N
169253
DC1-12011FB-A6SN
169254

IP20/NEMA 0

DC1-12015NB-A20N
169237
DC1-12015NB-A66N
169238
DC1-12015NB-A6SN
169239

IP66/NEMA 4X

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C

2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or

1800 rpm (at 60 Hz)
Information relevant for export to North America → page 11

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

15

DC1, for three-phase motors 230 V

P

Ie

A

kW

A

Frame size

Protection type

Part no.
Article no.

FS1

IP20/NEMA 0

DC1-322D3NN-A20N
169255
DC1-322D3NN-A66N
169256
DC1-322D3NN-A6SN
169257

Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
2.3
0.37
2
-

-

✓

-

-

-

✓

-

-

-

✓

✓

-

-

✓

-

IP20/NEMA 0

-

-

✓

-

IP66/NEMA 4X

-

-

✓

✓

-

-

✓

-

FS1

-

✓

✓

-

FS2

✓

✓

✓

-

-

-

✓

-

-

-

✓

✓

-

✓

✓

-

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

Price
see price
list

Std. pack

DC1, DA1

Fitted with

Local controls

Rated motor
current

7-digital display
assembly

Assigned motor
rating 2)

Brake chopper

Rated
operational
current1)
Ie

Radio interference
suppression filter

DC1, for three-phase motors 230 V

Ue 230 V AC, 3-phase / U2 230 V AC, 3-phase

4.3

7

10.5

18

Notes

0.75

1.5

2.2

4

3.2

6.3

8.7

14.8

1) Rated

IP66/NEMA 4X

FS1

FS3

DC1-324D3NN-A20N
169258
DC1-324D3NN-A66N
169259
DC1-324D3NN-A6SN
169260

IP20/NEMA 0

DC1-327D0NN-A20N
169261
DC1-327D0NB-A20N
169264
DC1-327D0FB-A20N
169444

IP66/NEMA 4X

DC1-327D0NN-A66N
169262
DC1-327D0NN-A6SN
169263
DC1-327D0NB-A66N
169436
DC1-327D0NB-A6SN
169437
DC1-327D0FB-A66N
169445
DC1-327D0FB-A6SN
169446

FS2

FS2

1 off

IP20/NEMA 0

DC1-32011NB-A20N
169438
DC1-32011FB-A20N
169447

IP66/NEMA 4X

DC1-32011NB-A66N
169439
DC1-32011NB-A6SN
169440
DC1-32011FB-A66N
169448
DC1-32011FB-A6SN
169449

IP20/NEMA 0

DC1-32018NB-A20N
169441
DC1-32018FB-A20N
169450

IP66/NEMA 4X

DC1-32018NB-A66N
169442
DC1-32018NB-A6SN
169443
DC1-32018FB-A66N
169451
DC1-32018FB-A6SN
169452

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C

2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or

1800 rpm (at 60 Hz)
Information relevant for export to North America → page 11

CA04020001Z-EN-INT

www.eaton.eu

16

PowerXL™ variable frequency drives
DC1, for three-phase motors 400 V

Fitted with

P

Ie

A

kW

A

Local controls

Rated motor
current

7-digital display
assembly

Assigned motor
rating 2)

Brake chopper

Rated
operational
current1)
Ie

Radio interference
suppression filter

DC1, for three-phase motors 400 V

-

✓

-

✓

-

✓

-

-

-

✓

-

-

-

✓

✓

✓

-

✓

-

✓

-

✓

✓

-

-

✓

-

✓

-

✓

-

-

✓

✓

-

✓

✓

✓

-

-

-

✓

-

-

-

✓

✓

✓

-

✓

-

-

✓

✓

-

-

✓

✓

✓

✓

-

✓

✓

✓

✓

Frame size

Protection type

Part no.
Article no.

FS1

IP20/NEMA 0

DC1-342D2NN-A20N
169453
DC1-342D2FN-A20N
169475

IP66/NEMA 4X

DC1-342D2NN-A66N
169454
DC1-342D2NN-A6SN
169455
DC1-342D2FN-A66N
169476
DC1-342D2FN-A6SN
169477

FS1

IP20/NEMA 0

DC1-344D1NN-A20N
169456
DC1-344D1FN-A20N
169478
DC1-344D1NB-A20N
169459
DC1-344D1FB-A20N
169481

FS1

IP66/NEMA 4X

DC1-344D1NN-A66N
169457
DC1-344D1NN-A6SN
169458
DC1-344D1FN-A66N
169479

Price
see price
list

Std. pack

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase
Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
2.2
0.75
1.9
-

4.1

5.8

Notes

1.5

3.6

2.2

5

1) Rated

FS2

DC1-344D1NB-A66N
169460
DC1-344D1NB-A6SN
169461

✓

FS1

✓

-

FS2

✓

✓

✓

DC1-344D1FN-A6SN
169480
DC1-344D1FB-A66N
169482
DC1-344D1FB-A6SN
169483

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

FS2

IP20/NEMA 0

DC1-345D8NB-A20N
169462
DC1-345D8FB-A20N
169484

IP66/NEMA 4X

DC1-345D8NB-A66N
169463
DC1-345D8NB-A6SN
169464
DC1-345D8FB-A66N
169485
DC1-345D8FB-A6SN
169486

1 off

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C

2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or

1800 rpm (at 60 Hz)
Information relevant for export to North America → page 11

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

17

DC1, for three-phase motors 400 V

P

Ie

A

kW

A

Frame size

Protection type

Part no.
Article no.

FS2

IP20/NEMA 0

DC1-349D5NB-A20N
169465
DC1-349D5FB-A20N
169487

IP66/NEMA 4X

DC1-349D5NB-A66N
169466
DC1-349D5NB-A6SN
169467
DC1-349D5FB-A66N
169488
DC1-349D5FB-A6SN
169489

IP20/NEMA 0

DC1-34014NB-A20N
169468
DC1-34014FB-A20N
169490

IP66/NEMA 4X

DC1-34014NB-A66N
169469
DC1-34014NB-A6SN
169470
DC1-34014FB-A66N
169491
DC1-34014FB-A6SN
169492

IP20/NEMA 0

DC1-34018NB-A20N
169471
DC1-34018FB-A20N
169493

IP66/NEMA 4X

DC1-34018NB-A66N
169472
DC1-34018NB-A6SN
169473
DC1-34018FB-A66N
169494
DC1-34018FB-A6SN
169495
DC1-34024NB-A20N
169474
DC1-34024FB-A20N
169496

✓

✓

-

✓

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

-

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

-

IP20/NEMA 0

✓

✓

✓

-

IP20/NEMA 0

Price
see price
list

Std. pack

DC1, DA1

Fitted with

Local controls

Rated motor
current

7-digital display
assembly

Assigned motor
rating 2)

Brake chopper

Rated
operational
current1)
Ie

Radio interference
suppression filter

DC1, for three-phase motors 400 V

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase
Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
9.5
4
8.5
-

14

18

24

Notes

5.5

7.5

11

1) Rated

11.3

15.2

21.7

FS3

1 off

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C

2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz) or

1800 rpm (at 60 Hz)
Information relevant for export to North America → page 11

CA04020001Z-EN-INT

www.eaton.eu

18

PowerXL™ variable frequency drives
DA1

Key to type references
DA1

DA1 - 1 2 4D3 F B - A 20 N
Device series

Type

DA1 = variable frequency drive, compact, series 1
(D = Drives, A = Advanced, 1 = Series 1)

N = Standard basic device
C = coated printed circuit boards

Connection in power section

Degree of protection

1 = single-phase mains connection/
three-phase motor connection
3 = three-phase mains connection/
three-phase motor connection

20 = IP20/NEMA 0
40 = IP40
55 = IP55/NEMA 3
66 = IP66/NEMA 4X
6S = IP66 with switch/NEMA 4X, switched

Mains voltage category
2 = 230 V (200 - 240 V ± 10 %)
4 = 400 V (380 - 480 V ± 10 %)

Display unit (display)
A = LED display
B = OLED display

Rated operational current (examples)
Brake chopper

4D3 = 4,3 A
024 = 24 A
248 = 248 A

N = no internal brake chopper
B = Brake chopper
EMC (radio interference suppression filter)
N = no internal RFI filter
F = Internal RFI filter

UL/CSA
Information relevant for export to North America
Product Standards
UL File No.
UL Category Control No.
CSA File No.
CSA Class No.
North America Certification
Suitable for
Max. Voltage Rating

CA04020001Z-EN-INT

UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking
E172143
NMMS, NMMS7
UL report applies to both US and Canada
3211-06
UL listed, certified by UL for use in Canada
Branch circuits
1~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey)
3~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey)
3~ 480 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey)

www.eaton.eu

PowerXL™ variable frequency drives

19

DA1

Sizes and degree of protection
Frame size

Protection type
IP20/NEMA 0

IP66/NEMA 4X

DC1, DA1

DA1

IP66/NEMA 4X
Local controls

FS2
⏚

DC- L1/L L2/N
L3

0

REV

FWD

PWR

OFF

ON

COM

1 2 3 4
5 6 7 8
9 10 11 12
13

14 15 16 17

⏚

DC+ BR

U

18

V

W

FS3
⏚

DC- L1/L L2/N
L3

0

REV

FWD

PWR

OFF

ON

COM

1 2 3 4
5 6 7 8
9 10 11 12
13

14 15 16 17

⏚

Frame size

DC+ BR

U

V

18

W

Protection type
IP55/NEMA 3

IP40

FS4

-

-

FS5

-

-

Panel version

-

FS5
FS8

-

CA04020001Z-EN-INT

www.eaton.eu

20

PowerXL™ variable frequency drives
DA1, for three-phase motors 230 V

DA1, for three-phase motors 230 V

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

Rated motor
current
Ie

Brake chopper

Assigned motor
rating 2)
P

Radio interference
suppression filter

Rated operational
current1)
Ie

Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
4.3
0.75
3.2
✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

✓

-

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

✓

✓

✓

✓

-

-

-

✓

✓

✓

-

✓

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

✓

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

✓

-

✓

✓

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

-

✓

✓

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

✓

-

✓

✓

✓

✓

✓

✓

-

✓

✓

Frame size

Protection type

Part no.
Article no.

FS2

IP20/NEMA 0

DA1-124D3FB-A20N
169152
DA1-124D3FB-A20C
169078

IP66/NEMA 4X

DA1-124D3FB-A66N
169153
DA1-124D3FB-B66N
169280
DA1-124D3FB-B66C
169347
DA1-124D3FB-A6SN
169154
DA1-124D3FB-B6SN
169281
DA1-124D3FB-A66C
169079
DA1-124D3FB-A6SC
169080
DA1-124D3FB-B6SC
169348

IP20/NEMA 0

DA1-127D0FB-A20N
169155
DA1-127D0FB-A20C
169081

IP66/NEMA 4X

DA1-127D0FB-A66N
169156
DA1-127D0FB-B66N
169282
DA1-127D0FB-A66C
169082
DA1-127D0FB-B6SN
169283
DA1-127D0FB-B66C
169349
DA1-127D0FB-A6SN
169157
DA1-127D0FB-B6SC
169350
DA1-127D0FB-A6SC
169083

IP20/NEMA 0

DA1-12011FB-A20N
169158
DA1-12011FB-A20C
169084

IP66/NEMA 4X

DA1-12011FB-A66N
169159
DA1-12011FB-B66N
169284
DA1-12011FB-A6SN
169160
DA1-12011FB-B6SN
169285
DA1-12011FB-B66C
169351
DA1-12011FB-A66C
169085
DA1-12011FB-B6SC
169352
DA1-12011FB-A6SC
169086

Price
see
price list

Std. pack

Ue 230 V AC, 1-phase / U2 230 V AC, 3-phase

7

10.5

Notes

1.5

2.2

1) Rated

6.3

8.7

FS2

FS2

1 off

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → page 18
CA04020001Z-EN-INT
www.eaton.eu
2) Assigned

PowerXL™ variable frequency drives

21

DA1, for three-phase motors 400 V
DA1, for three-phase motors 400 V

Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
4.3
0.75
3.2
✓

✓

✓

-

-

-

✓

✓

✓

-

✓

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

-

✓

✓

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

✓

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

✓

-

✓

-

✓

✓

-

✓

✓

-

✓

✓

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

-

✓

-

✓

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

✓

Frame size

Protection type

Part no.
Article no.

FS2

IP20/NEMA 0

DA1-324D3FB-A20N
169161
DA1-324D3FB-A20C
169087

IP66/NEMA 4X

DA1-324D3FB-A66N
169162
DA1-324D3FB-B66N
169286
DA1-324D3FB-B6SN
169287
DA1-324D3FB-B66C
169353
DA1-324D3FB-A6SN
169163
DA1-324D3FB-A66C
169088
DA1-324D3FB-B6SC
169354
DA1-324D3FB-A6SC
169089

IP20/NEMA 0

DA1-327D0FB-A20N
169164
DA1-327D0FB-A20C
169090

IP66/NEMA 4X

DA1-327D0FB-A66N
169165
DA1-327D0FB-B66N
169288
DA1-327D0FB-A66C
169091
DA1-327D0FB-B66C
169355
DA1-327D0FB-A6SN
169166
DA1-327D0FB-B6SN
169289
DA1-327D0FB-B6SC
169356
DA1-327D0FB-A6SC
169092

IP20/NEMA 0

DA1-32011FB-A20N
169167
DA1-32011FB-A20C
169093

IP66/NEMA 4X

DA1-32011FB-A66N
169168
DA1-32011FB-B66N
169290
DA1-32011FB-A6SN
169169
DA1-32011FB-B66C
169357
DA1-32011FB-B6SN
169291
DA1-32011FB-A66C
169094
DA1-32011FB-A6SC
169095
DA1-32011FB-B6SC
169358

Price
see price
list

Std. pack

DC1, DA1

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

Rated motor
current
Ie

Brake chopper

Assigned motor
rating 2)
P

Radio interference
suppression filter

Rated operational
current1)
Ie

Ue 230 V AC, 3-phase / U2 230 V AC, 3-phase

7

10.5

Notes

1.5

2.2

1) Rated

6.3

8.7

FS2

FS2

1 off

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → page 18
CA04020001Z-EN-INT
www.eaton.eu

2) Assigned

22

PowerXL™ variable frequency drives
DA1, for three-phase motors 230 V

DA1, for three-phase motors 230 V

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

P

Rated
motor
current
Ie

Brake chopper

Assigned motor
rating 2)

Radio interference
suppression filter

Rated
operational
current1)
Ie

Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
18
4
14.8
✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

-

✓

✓

✓

-

-

-

✓

✓

✓

-

✓

-

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

✓

✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

Frame size

Protection type

Part no.
Article no.

FS3

IP20/NEMA 0

DA1-32018FB-A20N
169170
DA1-32018FB-A20C
169096

IP66/NEMA 4X

DA1-32018FB-B66N
169292
DA1-32018FB-A66N
169171
DA1-32018FB-A6SN
169172
DA1-32018FB-B6SN
169293
DA1-32018FB-A66C
169097
DA1-32018FB-B66C
169359
DA1-32018FB-A6SC
169098
DA1-32018FB-B6SC
169360

FS3

IP20/NEMA 0

DA1-32024FB-A20N
169173
DA1-32024FB-A20C
169099

FS4

IP55

DA1-32024FB-A55N
169174
DA1-32024FB-B55N
169294
DA1-32024FB-B55C
169361
DA1-32024FB-A55C
169100

FS4

IP55/NEMA 3

DA1-32039FB-A55N
169175
DA1-32039FB-B55N
169295
DA1-32039FB-B55C
169362
DA1-32039FB-A55C
169101

Price
see price
list

Std. pack

Ue 230 V AC, 3-phase / U2 230 V AC, 3-phase

24

39

46

61

Notes

5.5

19.6

7.5

26.5

11

38

15

51

1) Rated

1 off

DA1-32046FB-A55N
169176
DA1-32046FB-B55N
169296
DA1-32046FB-B55C
169363
DA1-32046FB-A55C
169102
DA1-32061FB-A55N
169177
DA1-32061FB-B55N
169297
DA1-32061FB-B55C
169364
DA1-32061FB-A55C
169103

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → page 18

2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

23

DA1, for three-phase motors 230 V
DA1, for three-phase motors 230 V

Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
72
18.5
63
✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

-

-

✓

-

-

✓

-

✓

-

-

-

✓

-

✓

-

-

✓

✓

✓

-

✓

-

-

✓

✓

✓

-

-

-

✓

-

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

-

-

✓

-

-

✓

-

✓

-

-

-

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

-

-

✓

-

✓

✓

-

✓

-

-

✓

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

-

-

✓

-

-

✓

-

✓

-

-

-

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

-

-

✓

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

Frame size

Protection type

Part no.
Article no.

FS5

IP55/NEMA 3

DA1-32072FB-A55N
169178
DA1-32072FB-B55N
169298
DA1-32072FB-A55C
169104
DA1-32072FB-B55C
169365

Price
see price
list

Std. pack

DC1, DA1

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

P

Rated
motor
current
Ie

Brake chopper

Assigned motor
rating 2)

Radio interference
suppression filter

Rated
operational
current1)
Ie

Ue 230 V AC, 3-phase / U2 230 V AC, 3-phase

90

110

150

Notes

22

30

453)

71

96

141

FS6

1 off

DA1-32090FN-B55N
169299
DA1-32090FN-A55N
169179
DA1-32090FN-A55C
169105
DA1-32090FB-B55N
169300
DA1-32090FB-A55N
169180
DA1-32090FN-B55C
169366
DA1-32090FB-A55C
169106
DA1-32090FB-B55C
169367
DA1-32110FN-B55N
169301
DA1-32110FN-A55N
169181
DA1-32110FB-A55N
169182
DA1-32110FB-B55N
169302
DA1-32110FN-B55C
169368
DA1-32110FN-A55C
169107
DA1-32110FB-A55C
169108
DA1-32110FB-B55C
169369
DA1-32150FN-B55N
169303
DA1-32150FN-A55N
169183
DA1-32150FB-A55N
169184
DA1-32150FB-B55N
169304
DA1-32150FN-B55C
169370
DA1-32150FN-A55C
169109
DA1-32150FB-B55C
169371
DA1-32150FB-A55C
169110

1) Rated

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
3) Alternatively: allocated motor output of 37 kW (230 V) with 117-A rated motor current
Information relevant for export to North America → page 18
2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

24

PowerXL™ variable frequency drives
DA1, for three-phase motors 230 V

DA1, for three-phase motors 230 V

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

P

Rated
motor
current
Ie

Brake chopper

Assigned motor
rating 2)

Radio interference
suppression filter

Rated
operational
current1)
Ie

Mains voltage (50/60Hz) ULN 200 (-10%) - 240 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
180
553)
173
✓

-

-

✓

-

-

✓

-

✓

-

-

-

✓

✓

✓

-

-

-

✓

-

✓

-

-

✓

✓

-

-

✓

-

✓

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

-

-

✓

-

-

✓

-

✓

-

-

-

✓

✓

✓

-

-

-

✓

-

✓

-

-

✓

✓

✓

-

✓

-

-

✓

-

-

✓

-

✓

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

-

-

✓

-

-

✓

-

✓

-

-

-

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

-

-

✓

-

✓

✓

-

✓

-

-

✓

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

Frame size

Protection type

Part no.
Article no.

FS6

IP55

DA1-32180FN-B55N
169305
DA1-32180FN-A55N
169185
DA1-32180FB-A55N
169186
DA1-32180FN-A55C
169111
DA1-32180FN-B55C
169372
DA1-32180FB-B55N
169306
DA1-32180FB-B55C
169373
DA1-32180FB-A55C
169112

Price
see price
list

Std. pack

Ue 230 V AC, 3-phase / U2 230 V AC, 3-phase

202

248

Notes

55

173

75

233

1) Rated

FS7

1 off

DA1-32202FN-B55N
169307
DA1-32202FN-A55N
169187
DA1-32202FB-A55N
169188
DA1-32202FN-A55C
169113
DA1-32202FB-B55N
169308
DA1-32202FN-B55C
169374
DA1-32202FB-B55C
169375
DA1-32202FB-A55C
169114
DA1-32248FN-B55N
169309
DA1-32248FN-A55N
169189
DA1-32248FB-A55N
169190
DA1-32248FB-B55N
169310
DA1-32248FN-B55C
169376
DA1-32248FN-A55C
169115
DA1-32248FB-A55C
169116
DA1-32248FB-B55C
169377

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
3) Alternatively: allocated motor output of 45 kW (230 V) with 141-A rated motor current
Information relevant for export to North America → page 18
2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

25

DA1, for three-phase motors 400 V
DA1, for three-phase motors 400 V

Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
2.2
0.75
1.9
✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

✓

-

✓

✓

-

✓

-

✓

✓

✓

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

-

✓

✓

✓

✓

✓

✓

-

✓

✓

✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

-

✓

-

✓

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

✓

✓

✓

✓

✓

-

✓

✓

Frame size

Protection type

Part no.
Article no.

FS2

IP20/NEMA 0

DA1-342D2FB-A20N
169191
DA1-342D2FB-A20C
169117

IP66/NEMA 4X

DA1-342D2FB-A66N
169192
DA1-342D2FB-B66N
169311
DA1-342D2FB-A6SN
169193
DA1-342D2FB-A66C
169118
DA1-342D2FB-B6SN
169312
DA1-342D2FB-B66C
169378
DA1-342D2FB-B6SC
169379
DA1-342D2FB-A6SC
169119

IP20/NEMA 0

DA1-344D1FB-A20N
169194
DA1-344D1FB-A20C
169120

IP66/NEMA 4X

DA1-344D1FB-A66N
169195
DA1-344D1FB-B66N
169313
DA1-344D1FB-A6SN
169196
DA1-344D1FB-B6SN
169314
DA1-344D1FB-A66C
169049
DA1-344D1FB-B66C
169380
DA1-344D1FB-B6SC
169381
DA1-344D1FB-A6SC
169050

IP20/NEMA 0

DA1-345D8FB-A20N
169197
DA1-345D8FB-A20C
169051

IP66/NEMA 4X

DA1-345D8FB-A66N
169198
DA1-345D8FB-B66N
169315
DA1-345D8FB-A6SN
169199
DA1-345D8FB-B66C
169382
DA1-345D8FB-B6SN
169316
DA1-345D8FB-A66C
169052
DA1-345D8FB-B6SC
169383
DA1-345D8FB-A6SC
169053

Price
see price
list

Std. pack

DC1, DA1

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

Rated motor
current
Ie

Brake chopper

Assigned motor
rating 2)
P

Radio interference
suppression filter

Rated operational
current1)
Ie

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase

4.1

5.8

Notes

1.5

2.2

1) Rated

3.6

5

FS2

FS2

1 off

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → page 18
CA04020001Z-EN-INT
www.eaton.eu

2) Assigned

26

PowerXL™ variable frequency drives
DA1, for three-phase motors 400 V

DA1, for three-phase motors 400 V

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

Rated motor
current
Ie

Brake chopper

Assigned motor
rating 2)
P

Radio interference s
uppression filter

Rated operational
current1)
Ie

Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
9.5
4
8.5
✓

✓

✓

-

-

-

✓

✓

✓

-

✓

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

✓

-

✓

✓

✓

-

✓

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

✓

✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

-

✓

✓

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

✓

✓

✓

✓

-

-

-

✓

✓

✓

-

✓

✓

✓

✓

-

✓

-

-

✓

✓

✓

-

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

✓

-

✓

✓

-

✓

✓

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

✓

✓

✓

✓

-

✓

✓

✓

Frame size

Protection type

Part no.
Article no.

FS2

IP20/NEMA 0

DA1-349D5FB-A20N
169200
DA1-349D5FB-A20C
169054

IP66/NEMA 4X

DA1-349D5FB-A66N
169201
DA1-349D5FB-B66N
169317
DA1-349D5FB-A66C
169055
DA1-349D5FB-B6SN
169318
DA1-349D5FB-A6SN
169202
DA1-349D5FB-B66C
169384
DA1-349D5FB-A6SC
169056
DA1-349D5FB-B6SC
169385

IP20/NEMA 0

DA1-34014FB-A20N
169203
DA1-34014FB-A20C
169057

IP66/NEMA 4X

DA1-34014FB-A66N
169204
DA1-34014FB-B66N
169319
DA1-34014FB-A6SN
169205
DA1-34014FB-B6SN
169320
DA1-34014FB-B66C
169386
DA1-34014FB-A66C
169058
DA1-34014FB-A6SC
169059
DA1-34014FB-B6SC
169387

IP20/NEMA 0

DA1-34018FB-A20N
169206
DA1-34018FB-A20C
169060

IP66/NEMA 4X

DA1-34018FB-B66N
169321
DA1-34018FB-A66N
169207
DA1-34018FB-B66C
169388
DA1-34018FB-A6SN
169208
DA1-34018FB-B6SN
169322
DA1-34018FB-A66C
169061
DA1-34018FB-A6SC
169062
DA1-34018FB-B6SC
169389

Price
see price
list

Std. pack

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase

14

18

Notes

5.5

7.5

1) Rated

11.3

15.2

FS3

FS3

1 off

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → page 18
CA04020001Z-EN-INT
www.eaton.eu
2) Assigned

PowerXL™ variable frequency drives

27

DA1, for three-phase motors 400 V
DA1, for three-phase motors 400 V

Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
24
11
21.7
✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

-

✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

-

✓

-

-

✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

Frame size

Protection type

Part no.
Article no.

FS3

IP20/NEMA 0

DA1-34024FB-A20N
169209
DA1-34024FB-A20C
169063

FS4

IP55

DA1-34024FB-A55N
169210
DA1-34024FB-B55N
169323
DA1-34024FB-B55C
169390
DA1-34024FB-A55C
169064

Price
see price
list

Std. pack

DC1, DA1

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

P

Rated
motor
current
Ie

Brake chopper

Assigned motor
rating 2)

Radio interference
suppression filter

Rated
operational
current1)
Ie

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase

30

39

46

61

72

Notes

15

18.5

22

30

37

29.3

36

41

55

68

1 off

DA1-34030FB-B55N
169324
DA1-34030FB-A55N
169211
DA1-34030FB-A55C
169065
DA1-34030FB-B55C
169391
DA1-34039FB-B55N
169325
DA1-34039FB-A55N
169212
DA1-34039FB-A55C
169066
DA1-34039FB-B55C
169392
DA1-34046FB-A55N
169213
DA1-34046FB-B55N
169326
DA1-34046FB-B55C
169393
DA1-34046FB-A55C
169067
FS5

DA1-34061FB-A55N
169214
DA1-34061FB-B55N
169327
DA1-34061FB-A55C
169068
DA1-34061FB-B55C
169394
DA1-34072FB-A55N
169215
DA1-34072FB-B55N
169328
DA1-34072FB-A55C
169069
DA1-34072FB-B55C
169395

1) Rated

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → page 18

2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

28

PowerXL™ variable frequency drives
DA1, for three-phase motors 400 V

DA1, for three-phase motors 400 V

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

P

Rated
motor
current
Ie

Brake chopper

Assigned motor
rating 2)

Radio interference
suppression filter

Rated
operational
current1)
Ie

Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
90
45
81
✓

-

✓

-

-

-

✓

-

-

✓

-

-

✓

✓

✓

-

-

-

✓

-

✓

-

-

✓

✓

✓

-

✓

-

-

✓

-

-

✓

-

✓

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

-

✓

-

-

-

✓

-

-

✓

-

-

✓

✓

✓

-

-

-

✓

-

✓

-

-

✓

✓

-

-

✓

-

✓

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

-

-

✓

-

-

✓

-

✓

-

-

-

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

-

-

✓

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

Frame size

Protection type

Part no.
Article no.

FS6

IP55/NEMA 3

DA1-34090FN-A55N
169216
DA1-34090FN-B55N
169329
DA1-34090FB-A55N
169037
DA1-34090FN-A55C
169070
DA1-34090FB-B55N
169330
DA1-34090FN-B55C
169396
DA1-34090FB-B55C
169397
DA1-34090FB-A55C
169071

Price
see price
list

Std. pack

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase

110

150

Notes

55

99

75

134

1) Rated

1 off

DA1-34110FN-A55N
169038
DA1-34110FN-B55N
169331
DA1-34110FB-A55N
169039
DA1-34110FN-A55C
169072
DA1-34110FN-B55C
169398
DA1-34110FB-B55N
169332
DA1-34110FB-B55C
169399
DA1-34110FB-A55C
169265
DA1-34150FN-B55N
169333
DA1-34150FN-A55N
169040
DA1-34150FB-A55N
169041
DA1-34150FB-B55N
169334
DA1-34150FN-B55C
169400
DA1-34150FN-A55C
169266
DA1-34150FB-B55C
169401
DA1-34150FB-A55C
169267

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → page 18

2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

29

DA1, for three-phase motors 400 V
DA1, for three-phase motors 400 V

Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
180
90
161
✓

-

✓

-

-

-

✓

-

-

✓

-

-

✓

-

✓

-

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

-

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

-

✓

-

-

-

✓

-

-

✓

-

-

✓

✓

✓

-

-

-

✓

-

-

✓

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

-

-

✓

-

-

✓

-

✓

-

-

-

✓

-

✓

-

-

✓

✓

-

-

✓

-

✓

✓

✓

-

✓

-

-

✓

✓

✓

-

-

-

✓

✓

✓

-

-

✓

✓

✓

-

✓

-

✓

Frame size

Protection type

Part no.
Article no.

FS6

IP55

DA1-34180FN-A55N
169042
DA1-34180FN-B55N
169335
DA1-34180FN-A55C
169268
DA1-34180FB-A55N
169043
DA1-34180FB-B55N
169336
DA1-34180FN-B55C
169402
DA1-34180FB-A55C
169269
DA1-34180FB-B55C
169403

Price
see price
list

Std. pack

DC1, DA1

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

P

Rated
motor
current
Ie

Brake chopper

Assigned motor
rating 2)

Radio interference
suppression filter

Rated
operational
current1)
Ie

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase

202

240

Notes

110

132

196

231

FS7

1 off

DA1-34202FN-A55N
169044
DA1-34202FN-B55N
169337
DA1-34202FB-A55N
169045
DA1-34202FN-B55C
169404
DA1-34202FN-A55C
169270
DA1-34202FB-B55N
169338
DA1-34202FB-B55C
169405
DA1-34202FB-A55C
169271
DA1-34240FN-B55N
169339
DA1-34240FN-A55N
169046
DA1-34240FN-A55C
169272
DA1-34240FN-B55C
169406
DA1-34240FB-B55N
169340
DA1-34240FB-A55N
169047
DA1-34240FB-A55C
169273
DA1-34240FB-B55C
169407

1) Rated

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → page 18

2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

30

PowerXL™ variable frequency drives
DA1, for three-phase motors 400 V

DA1, for three-phase motors 400 V

Additional PCB
protection

A

Local controls

kW

OLED display

A

Fitted with

7-digital display
assembly

P

Rated
motor
current
Ie

Brake chopper

Assigned motor
rating 2)

Radio interference
suppression filter

Rated
operational
current1)
Ie

-

-

✓

-

✓

✓

-

-

✓

-

-

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

-

-

✓

✓

-

-

✓

-

-

✓

-

✓

-

-

-

✓

-

-

✓

-

✓

✓

✓

✓

-

-

-

✓

-

✓

-

-

✓

✓

✓

-

✓

-

-

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

✓

-

-

✓

-

-

✓

-

✓

-

-

-

✓

✓

-

✓

-

-

✓

✓

✓

-

-

-

✓

-

-

✓

-

✓

✓

-

✓

-

-

✓

✓

✓

-

✓

-

✓

✓

✓

✓

-

-

✓

Frame size

Protection type

Part no.
Article no.

Price
see price
list

FS7

IP55

DA1-34302FN-B55C
169408
DA1-34302FN-B55N
169341
DA1-34302FN-A55C
169274
DA1-34302FB-B55C
169217
DA1-34302FB-A55N
169073
DA1-34302FB-B55N
169342
DA1-34302FN-A55N
169048
DA1-34302FB-A55C
169275

1 off

FS8

IP40

DA1-34370FN-B40N
169343
DA1-34370FN-A40N
169074
DA1-34370FN-B40C
169218
DA1-34370FB-A40N
169075
DA1-34370FN-A40C
169276
DA1-34370FB-B40N
169344
DA1-34370FB-B40C
169219
DA1-34370FB-A40C
169277

1 off

Std. pack

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase
Mains voltage (50/60Hz) ULN 380 (-10%) - 480 (+10%) V
Interface OP-Bus (RS485)/Modbus RTU, CANopen®
302
160
279
-

370

450

Notes

200

349

250

437

1) Rated

DA1-34450FN-B40N
169345
DA1-34450FN-A40N
169076
DA1-34450FB-B40N
169346
DA1-34450FB-A40N
169077
DA1-34450FN-B40C
169220
DA1-34450FN-A40C
169278
DA1-34450FB-B40C
169221
DA1-34450FB-A40C
169279

operational current at an operating frequency of 4 kHz and an ambient air temperature of +50°C
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → page 18

2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

31

Accessories

Description

For use with

Part no.
Article no.

with LED display
Front IP54
With approx. 3 m-long, plug-in
connection cable (RJ45, 8-pin)
with OLED display
Front IP54
Multilingual
With approx. 3 m-long, plug-in
connection cable (RJ45, 8-pin)

DC1, DA1

DX-KEY-LED
169132

DC1, DA1

DX-KEY-OLED
169133

Price
see price
list

Std. pack

Information relevant for
export to North America

1 off

UL/CSA certification not
required

DX-COM-STICK
169134

1 off

UL/CSA certification not
required

DA1

DX-COM-SOFT
169136

1 off

UL/CSA certification not
required

DC1, DA1

DX-CBL-RJ45-0M5
169137
DX-CBL-RJ45-1M0
169138
DX-CBL-RJ45-3M0
169139

1 off

UL/CSA certification not
required

UL/CSA certification not
required

External keypad

Bluetooth communications stick
For transferring parameters to a computer with drivesConnect software via Bluetooth
With 2 function keys for uploading
DC1, DA1
and downloading parameters
with configuration memory

License Keys
For enabling the drivesConnect
program's PLC function

Connection cable
Connection cable with RJ45 plugs, 8 pole
Length 0.5 m
Length 1 m

DC1, DA1

Length 3 m

DC1, DA1

Bus termination resistor
With 2 resistors, 120 Ω
RJ45 plug, 8-pin
for CANopen® and Modbus RTU

DX-SPL-RJ45-2SL-1PLT

DX-CBL-TERM
169140

1 off

8 pole
RJ45
124 Ω
Connection to PIN 1 and PIN 2
für CANopen®

easyNet
easyNet

EASY-NT-R
256281

2 off

RJ45, 8-pin, 2 sockets/1 plug

DC1, DA1

DX-SPL-RJ45-2SL1PL
169142

1 off

UL/CSA certification not
required

DX-CBL-PC-1M5
171018

1 off

UL/CSA certification not
required

DX-COM-PCKIT
169135

1 off

UL/CSA certification not
required

Cable and splitter

Interface converter
For directly connecting the variable-frequency drive to a computer with drivesConnect
software
Interface converter USB/RS485 with DC1, DA1
connection cable, RJ45, 8 pole
electrically isolated

USB

PWR
RxD
TxD

Interface converter USB/RS485 with
connection cable, RJ45, 8 pole
electrically isolated
1 × SUB-D plug, 9-pole
Terminal strip, 5-terminal
LED indicators

DC1, DA1

CA04020001Z-EN-INT

www.eaton.eu

DC1, DA1

Accessories

32

PowerXL™ variable frequency drives
Accessories

Description

For use with

Part no.
Article no.

Price
see price
list

110-V-input
(electrically isolated)
230-V-input
(electrically isolated)
2 relay outputs
1 analog output
2 relay outputs

DC1

DXC-EXT-IO110
169032
DXC-EXT-IO230
169033
DXC-EXT-2RO1AO
169030
DXC-EXT-2RO
169031

3 digital inputs
1 Relay output
3 relay outputs

DA1

3 digital inputs
1 Relay output
1 Potentiometer

DC1

DXC-EXT-LOCSIM
169034

1 off

UL/CSA certification not
required

2-channel
max. 500 kHz
5 V TTL, A & B, /A & /B,
5 V DC, max. 200 mA
24 V HTL, A & B, /A & /B,
24 V DC, external power
supply required,
max. 30 V DC

DA1

DXA-EXT-ENCOD
169035

1 off

UL/CSA certification not
required

Std. pack

Information relevant for
export to North America

Expansion modules

1

2

1

2

3

3

4

5

4

5

6

6

7

7

8

8

9

9

10 11

DC1
DC1
DC1

1 off

10 11

A

DA1

B

DXA-EXT-3DI1RO
169036
DXA-EXT-3RO
169121

Simulator
1

2

3

4

5

6

7

8

9

10 11

Encoder module

A
B

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

33

Fieldbus connection

For use with

Part no.
Article no.

Ethernet IP

DA1

Modbus-TCP

DA1

EtherCAT

DA1

BACnet/IP

DA1

PROFINET

DA1

DeviceNet

DA1

DX-NET-ETHERNET-2
169122
DX-NET-MODBUSTCP-2
169126
DX-NET-ETHERCAT-2
169127
DX-NET-BACNETIP-2
169128
DX-NET-PROFINET-2
169125
DX-NET-DEVICENET
169123

PROFIBUS-DP

DA1

DX-NET-PROFIBUS
169124

SmartWire-DT

DA1 (IP20)

DX-NET-SWD1
169129

SmartWire-DT

DC1/DA1
(IP55/IP66)
DC1 (IP20)

DX-NET-SWD2
169130
DX-NET-SWD3
169131

Price
see price
list

Std. pack

Information relevant for
export to North America

1 off

UL/CSA certification not
required

1 off

UL/CSA certification not
required

Fieldbus modules
2 x RJ45, 8 pole

IN

OUT

Terminal strip, plug-in, 6-terminal

A
B

SUB-D socket, 9-pole

OP
ST
PROFIBUS

DP-V1

SmartWire-DT Modules
with slot for SWD4-8SF2-5

Ready

with slot for SWD4-8SF2-5

SmartWire-DT

Ready

I

A
O

CA04020001Z-EN-INT

www.eaton.eu

DC1, DA1

Accessories

34

PowerXL™ variable frequency drives
Braking resistances

Braking resistances

Resistance
value
R

Continuous
braking
rating
PDB

Ω

kW

Protection
type

For use
with

Part no.
Article no.

Price
see price
list

Std. pack

Information relevant for export to
North America

Braking resistances
Braking resistance in anodized aluminium enclosure
for direct installation in frequency inverter enclosure of frame sizes FS2 und FS3
100
0.2
IP54
DC1, DA1

Braking resistance in aluminum housing
for direct installation in frequency inverter enclosure of frame sizes FS4 und FS5
33
0.5
IP54
DA1

Braking resistance in aluminum housing
Installed in a housing designed to prevent accidental contact and featuring a
temperature monitoring switch and a 1-meter connection cable
75
1.4
IP20
DC1, DA1
100

1.4

IP20

DC1, DA1

100

0.8

IP20

DC1, DA1

100

1.6

IP20

DC1, DA1

150

0.5

IP20

DC1, DA1

150

1.4

IP20

DC1, DA1

200

0.8

IP20

DC1, DA1

200

0.4

IP20

DC1, DA1

400

0.4

IP20

DC1, DA1

Braking resistance in aluminum housing
Installed in a housing designed to prevent accidental contact and featuring a
temperature monitoring switch and internal connecting terminals
35
1.1
IP20
DA1
50

0.4

IP20

DC1, DA1

50

9.8

IP20

DC1, DA1

100

0.2

IP20

DC1, DA1

100

0.4

IP20

DC1, DA1

DX-BR3-100
169150

1 off

DX-BR5-033
169151

1 off

DX-BR075-1K4
171917
DX-BR100-1K4
171896
DX-BR100-0K8
171907
DX-BR100-1K6
171924
DX-BR150-0K5
171916
DX-BR150-1K4
171895
DX-BR200-0K8
171894
DX-BR200-0K4
171915
DX-BR400-0K4
171914

1 off

DX-BR035-1K1
171927
DX-BR050-0K4
171906
DX-BR050-0K8
171910
DX-BR100-0K2
171909
DX-BR100-0K4
171926

1 off

Product Standards
UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

Suitable for
Max. Voltage Rating
Degree of Protection

Product Standards
UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

Suitable for
Max. Voltage Rating
Degree of Protection

CA04020001Z-EN-INT

www.eaton.eu

UL508; C22.2
E300773
NMTR2,
NMTR8
E300773
14-M05
UL listed,
certified by
UL for use in
Canada
Branch
circuits
600
IEC: IP00

UL508; C22.2
E300773
NMTR2,
NMTR8
E300773
14-M05
UL listed,
certified by
UL for use in
Canada
Branch
circuits
600
IEC: IP00

PowerXL™ variable frequency drives

35

Resistance
value
R

Continuous
braking
rating
PDB

Ω

kW

Protection
type

For use
with

Braking resistance with steel wire mesh elements
Installed in a housing designed to prevent accidental contact and featuring a
temperature monitoring switch and internal connecting terminals
2
54.3
IP20
DA1
2

102.4

IP20

DA1

6

5.1

IP20

DA1

6

9.2

IP20

DA1

6

18.1

IP20

DA1

6

33.3

IP20

DA1

12

3.1

IP20

DA1

12

5.1

IP20

DA1

12

9.2

IP20

DA1

12

18.1

IP20

DA1

22

1.4

IP20

DA1

22

3.1

IP20

DA1

22

5.1

IP20

DA1

22

9.2

IP20

DA1

40

3.1

IP20

DA1

40

5.1

IP20

DA1

47

3.1

IP20

DC1, DA1

47

5.1

IP20

DC1, DA1

47

9.2

IP20

DC1, DA1

50

3.1

IP20

DC1, DA1

50

5.1

IP20

DC1, DA1

75

5.1

IP20

DC1, DA1

100

6.2

IP20

DC1, DA1

Part no.
Article no.

DX-BR002-54K3
171923
DX-BR002-102K4
171903
DX-BR006-5K1
171913
DX-BR006-9K2
171893
DX-BR006-18K1
171922
DX-BR006-33K3
171902
DX-BR012-3K1
171912
DX-BR012-5K1
171929
DX-BR012-9K2
171921
DX-BR012-18K1
171901
DX-BR022-1K4
171911
DX-BR022-3K1
171928
DX-BR022-5K1
171920
DX-BR022-9K2
171900
DX-BR040-3K1
171919
DX-BR040-5K1
171899
DX-BR047-3K1
171908
DX-BR047-5K1
171925
DX-BR047-9K2
171905
DX-BR050-3K1
171918
DX-BR050-5K1
171898
DX-BR075-5K1
171897
DX-BR100-6K2
171904

Price
see price
list

Std. pack

Information relevant for export to
North America

1 off

Product Standards
UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

Suitable for
Max. Voltage Rating
Degree of Protection

CA04020001Z-EN-INT

UL508; C22.2
E300773
NMTR2,
NMTR8
E300773
14-M91
UL listed,
certified by
UL for use in
Canada
Branch
circuits
1000
IEC: IP00

www.eaton.eu

DC1, DA1

Braking resistances

36

PowerXL™ variable frequency drives
Mains chokes, motor chokes

Mains chokes, motor chokes

Rated
operational
current
Ie

Inductance

Maximum heat
dissipation

L

Pv

A

mH

W

Single-phase
max. permitted mains supply voltage V AC: 260 V + 0% (50/60 Hz)
5.8

5.05

9

8.6

3.41

11

13

2.25

12

18

1.63

17

24

1.22

20

32

0.92

24

7.51

17

6

4.9

19

10

2.94

33

16

1.84

44

25

1.18

57

40

0.64

59

50

0.37

58

60

0.31

60

80

0.23

86

100

0.18

101

120

0.15

100

160

0.11

140

200

0.09

154

250

0.07

155

300

0.06

196

303

0.06

230

370

0.05

290

450

0.04

300

Part no.
Article no.

Price
see price list

Std. pack

Mains chokes

three-phase
max. permitted mains supply voltage V AC: 550 V + 0% (50/60 Hz)
3.9

Motor chokes

1 off

DX-LN3-004
269500
DX-LN3-006
269501
DX-LN3-010
269502
DX-LN3-016
269503
DX-LN3-025
269504
DX-LN3-040
269505
DX-LN3-050
269506
DX-LN3-060
269507
DX-LN3-080
269508
DX-LN3-100
269509
DX-LN3-120
269510
DX-LN3-160
269511
DX-LN3-200
269512
DX-LN3-250
269513
DX-LN3-300
269514
DX-LN3-303
169143
DX-LN3-370
169144
DX-LN3-450
169145

1 off

DX-LM3-005
269538
DX-LM3-008
269539
DX-LM3-011
269541
DX-LM3-016
269542
DX-LM3-035
269543
DX-LM3-050
269544

1 off

max. heat dissipation
(pulse frequency)
(12 kHz)

three-phase
max. permitted mains supply voltage V AC: 750 V + 0% (50/60 Hz)
5

CA04020001Z-EN-INT

DX-LN1-006
269490
DX-LN1-009
269495
DX-LN1-013
269496
DX-LN1-018
269497
DX-LN1-024
269498
DX-LN1-032
169791

www.eaton.eu

2

24

8

4.1

54

11

3

71

16

1.5

78

35

1

116

50

0.6

168

PowerXL™ variable frequency drives

37

Motor chokes, sine filters
Motor chokes, sine filters

Inductance

Maximum heat
dissipation

L

Pv

A

mH

W

Motor chokes

Part no.
Article no.

Price
see price list

Std. pack

DC1, DA1

Rated
operational
current
Ie

max. heat dissipation
(pulse frequency)
(12 kHz)

three-phase
max. permitted mains supply voltage V AC: 750 V + 0% (50/60 Hz)
63

0.5

193

80

0.5

206

100

0.45

294

150

0.35

424

180

0.3

439

220

0.2

517

260

0.15

520

303

0.15

-

370

0.12

-

450

0.1

-

4

11

50

10

5.1

100

16.5

3.07

70

23.5

2.5

125

32

2

100

37

1.7

100

48

1.2

240

61

1

280

72

0.95

300

90

0.8

290

115

0

460

150

0.5

530

180

0.4

500

250

0.35

550

440

0.14

650

480

0.14

1550

DX-LM3-063
269545
DX-LM3-080
269546
DX-LM3-100
269547
DX-LM3-150
269548
DX-LM3-180
269549
DX-LM3-220
269560
DX-LM3-260
269561
DX-LM3-303
169146
DX-LM3-370
169147
DX-LM3-450
169148

1 off

DX-SIN3-004
271538
DX-SIN3-010
271590
DX-SIN3-016
271591
DX-SIN3-023
271593
DX-SIN3-032
271594
DX-SIN3-037
271595
DX-SIN3-048
271597
DX-SIN3-061
271599
DX-SIN3-072
271600
DX-SIN3-090
271601
DX-SIN3-115
271602
DX-SIN3-150
271603
DX-SIN3-180
271604
DX-SIN3-250
271605

1 off

DX-SIN3-440
271606
DX-SIN3-480
169149

1 off

Sine filter
three-phase

Instructions

1 off

Information relevant for export to North America
Product Standards
UL File No.
UL Category Control No.
CSA File No.
CSA Class No.
North America Certification
Suitable for
Max. Voltage Rating
Degree of Protection

UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking
E167225
XPTQ2, XPTQ8
UL report applies to both US and Canada
3211-06
UL listed, certified by UL for use in Canada
Branch circuits
1~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey)
IEC: IP00

CA04020001Z-EN-INT

www.eaton.eu

38

PowerXL™ variable frequency drives
Radio interference suppression filters

Radio interference suppression filters

Input current

For use with

Part no.
Article no.

DC1-12
DA1-12…

DX-EMC12-008
172273
DX-EMC12-012
172274
DX-EMC12-016
172275
DX-EMC12-020
172276
DX-EMC12-030
172277

1 off

DC1-32…
DC1-34…
DA1-32…
DA1-34…

DX-EMC34-008
172278
DX-EMC34-012
172279
DX-EMC34-016
172280
DX-EMC34-030
172281

1 off

DA1-32…
DA1-34…

DX-EMC34-042
172282
DX-EMC34-055
172283
DX-EMC34-075
172284
DX-EMC34-100
172285
DX-EMC34-130
172286
DX-EMC34-180
172287
DX-EMC34-250
172288
DX-EMC34-400
172289

ILN

Price
see price list

Std. pack

T

Radio interference suppression filters
Single-phase
Mains voltage (50/60Hz) ULN [V] max. 240 + 10%
Base-mounted filter
8
12
16
20
30
three-phase
Mains voltage (50/60Hz) ULN [V] max. 480 + 10%
Base-mounted filter
8
12
16
30
Mounting to the side, next to the variable frequency drive
42
55
75
100
130
180
250
400

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

39

Assigned switching and protective elements

Engineering
AC supply system: Variable-frequency drives can be connected without restriction
to AC supply systems with a grounded star point (TN/TT grounding systems).
Directly connecting them to and running them on unbalanced or B phase-grounded
systems (e.g., USA) is not permissible.
Fuses (circuit-breakers) allow the protection of lines and electrical devices.
For the protection of persons, AC/DC-sensitive residual current circuit-breakers
(RCD Type B) are required in addition.

F

Contactors are used to switch the mains voltage on and off.

Q

Mains choke damp harmonic distortion (THD) and current peaks and limit inrush
currents (the DC link capacitors' charging current). In addition, they protect the
mains rectifier from voltage peaks coming from the mains.

R

Radio interference suppression filter attenuate high-frequency electromagnetic
emissions from devices. They ensure that the EMC limit values for conducted
interference specified in the applicable product standards are complied with
(variable-frequency drives).
Note: External radio interference suppression filters (optional) make it possible to
use longer motor cables and have low leakage currents. Normally, they should only
be used with variable-frequency drives that do not feature an internal radio
interference suppression filter.
Exception: directly assigned variable-frequency drives with internal filters
(calibrated combination)

K



variable frequency drive allow the continuously variable speed control of threephase motors. To do this, the variable-frequency drive converts the voltage of the
AC supply system with a constant voltage and a constant frequency to a new AC
voltage with a variable amplitude and a variable frequency.

L1/L L2/N
L3

T
3~

R

On brake resistor converts the variable frequency drive's regenerative braking
energy into heat. The variable frequency drive must be equipped with a brake
chopper, which connects the braking resistance parallel to the internal DC link.
1

2

3



4

5

6

7

U

8

9 10 11

V

W

Motor choke
• Compensate the capacitive capacitive currents,
• Reduce current ripple and the motor’s current change noise,
• Attenuate the retroaction on parallel connection of several motors.

R

sine filter
• Smoothen the output voltage sinusoidally,
• reduce motor noise through du/dt reduction, and thereby increase the motor
insulation’s lifespan,
• Reduce the leakage currents to allow better motor performance at improved EMC
values.

3

3
Screened motor cables attenuate radiated and conducted high-frequency
emissions within the limits defined in the applicable product standard (EMC). They
must be connected to the earth potential on both sides across a large area (PES).

M

M
3~

Three-phase asynchronous motor (standard motor) converts electric power
(P ~ U × I) into mechanical power (P ~ M × n).

Equipment code
F = fuses and circuit-breakers
Q = controlled switching within energy flow (contactors, circuit-breakers)
R = limitation (reactors, resistors)
K = radio interference suppression filters
T = variable-frequency drives
M = motors

CA04020001Z-EN-INT

www.eaton.eu

DC1, DA1

Assigned switching and protective elements

40

PowerXL™ variable frequency drives
General information on Engineering

Electrical mains connection
General information on Engineering

Frequency inverters can be connected
to and operated on star point-earthed
AC supply systems (as per IEC 60364)
without restrictions.

L1
L2
L3
N
PE

L1
L2
L3
PEN

Connecting them to and operating
them on asymmetrically earthed
networks, such as phase-earthed
delta networks (grounded delta, USA)
or non-earthed or high-resistance
earthed (> 30 Ω) IT networks is
permitted with limitations. In these

networks, only frequency inverters
without internal radio interference
suppression filters (EMC) may be used.
In the case of devices with an
integrated radio interference
suppression filter, the filter’s
protective earth connection must be
disconnected.
The standardized rated operating
voltages of the utility companies fulfil
the following conditions at the point of
transfer to the consumer:
• maximum deviation from the rated
voltage (ULN): ±10 %
• Maximum deviation in the voltage
symmetry: ±3 %
• Maximum deviation from the rated
frequency: ±4 %
A further voltage drop of up to 4% in
the consumer networks is permissible
relative to the lower voltage value
(ULN -10%) of the mains voltage.
In ring-operated mesh networks (such
as in the EU) the standardized
consumer voltages (230/400/690 V) are
identical to the utility company’s
supply voltages. In star networks (for
example in North America/USA), the
stated consumer voltages take the
voltage drop from the utility company’s
infeed point to the last consumer into
account.

Table: North American voltage level
Motor voltage according Consumer voltage, rated
Supply voltage ULN
of the EVU
to UL 508 C
value for the motors
120 V
110 - 120 V
115 V
240 V
220 - 240 V
230 V
480 V
440 - 480 V
460 V
600 V
550 - 600 V
575V

Public medium-voltage system

Public
low-voltage system

Category C1 / C2

For frequency inverters, the
components placed on the mains-side
are assigned as per the input-side
rated operational current ILN and the
AC-1 utilization category.
Fuses, circuit-breakers and conductor
cross-sections must meet the national
and regional requirements and the
required approvals at the point of
operation.
For fire prevention and the protection
of persons and domestic animals from
excessive contact voltages residual
current devices (RCD) must be used.
Only AC/DC sensitive residual current
devices (RCD, type B) may be used in
connection with a frequency inverter.

Frequency inverters work with fast
electronic switches (IGBT) in the
inverter. This can cause radio
interference in a drive system, which,
in turn, can adversely affect nearby
electronic equipment. To provide
protection from this high-frequency
interference, these should be spatially
separated and screened from
frequency-controlled drives.
In Europe, adherence to the EMC
Directive is mandatory. The EMC
product standard for power drive
systems (PDS) is IEC/EN 61800-3. This
standard covers the complete drive
system, from mains infeed to the
motor.
Both versions of DC1 and DA1 series
frequency inverters (with internal/
external radio interference
suppression filter) meet the
requirements of the EMC product
standard for residential areas (first
environment) and therefore the higher
limits for industrial environment
(second environment) as well.

Marking on residual current devices
for AC/DC sensitive RCDs, type B:

Earth leakage currents will be
produced when using frequencycontrolled drives due to the nature of
the system. The main reasons for this
consist of external capacitances
between the phases of the motor
cable, the motor cable's screening,
Y capacitors in the frequency inverter,
and radio interference suppression
filters, as well as earthing measures at
the motor's site of operation. These
leakage currents can exceed 3.5 mA
and require improved PDS earthing as
per EN 50178 (earth conductor crosssection ≥ 10 mm2).

CA04020001Z-EN-INT

www.eaton.eu

Category C1 / C2
Category C3 / C4

Category C3 / C4

Category C2
1.or 2. environment

1. Environment

2. Environment

Frequency inverters
A frequency inverter is an electronic
apparatus used for the variable-speed
control of three-phase motors. It is
intended for installation in a machine
or for assembly with other
components to a machine or plant. The
main components of a modern
compact frequency inverter are a
power section ① and a control
section ②.



The functional control of the frequency
inverter and the output values in the
power section (such as frequency,
voltage and current) can be adjusted
through:
• Control terminals (I/O) with analog
and digital (binary) inputs,
• A keypad with function keys and
display units,
• Serial interfaces (BUS) with RS485
(Modbus RTU) and optional
fieldbus connections (CANopen,
PROFIBUS-DP etc.) and an optional
PC connection.
Internal open and closed-loop control
circuits monitor all variable values in
the frequency inverter and
automatically switch the process off if
a value reaches a dangerous level.
The power section of a static compact
frequency generally consists of three
subgroups:
• Rectifier (A),
• Internal DC link (B),
• Inverter module (C).

①

DC- L1/L L2/N
L3

②
COM

1 2 3 4
5 6 7 8
9 10 11 12
13

14 15 16 17

EMC compliance

Industrial
mains

Category C1

 DC+
BR

Safety and switching

Private
mains

PCC

U

18

V

W

① Power section with:
A = Rectifier
B = Internal DC link
C = inverter (IGBT)
② Control section with:
I/O = Analog and binary
inputs and outputs
KEYPAD = Operating unit with
display unit
BUS = Serial ports/interfaces
(RS485, field bus, PC interface)

I/O
KEYPAD
BUS

CPU

M
3∼
A

ULN = phase voltage
fromsupplying AC
mains

B

UDC = DC link voltage
UDC = 1.41 x ULN

C

Output voltage =
switched DC link
voltage with sinusoidal
pulse width modulation (PWM)
Block diagram with main components of a frequency inverter

PowerXL™ variable frequency drives

41

Control methods

Bei der In sensorless vector control
the magnetic fields of the stator and
rotor windings are aligned so as to
oppose each other. With
asynchronous motors the magnetic
flux in the rotor must be mapped in an
electronic model of the motor. This
requires the physical parameters on
the motor’s rating plate to be entered.
In vector operation the
frequencyinverter can control only
one motor. A parallel operation of
several motors is not possible here.
The exact calculation of the phase
voltages at the variable frequency
drive’s output, however, improves the
motor’s operational behavior. The
motor also heats up less in the lower
speed range. The field-oriented vector
control results in a significant
improvement in the drive dynamics as
well as optimizing performance; it also
increases the range of possible
applications.
The main applications of
sensorlessvector control are:

General information on Engineering

The IGBTs in the variable frequency
series' inverter are controlled with
sinusoidal pulse-width modulation
(PWM). In real-life applications, the
industry draws a distinction between
the following control methods:
• Voltage frequency control
(U/f control),
• V/Hz control with slip compensation
• Sensorless vector control
(speed control)
• Vector control (closed-loop)
The Voltage frequency control is the
best known and most commonly used
method. A simple characteristic curve
(linear or quadratic) defines the
motor’s rotating field frequency and
the corresponding three-phase lineto-line motor voltage is selected such
that the motor is neither over nor
under-magnetized.

X1

①

Xh

②

③

① Stator winding
② Air gap
③ Transformed rotor winding
Simplified equivalent circuit diagram for a three-phase motor

• Material machining and processing
equipment
• Condensors (compressor),
• Heavy starting duty (extruder,
agitators, mixer),
• Horizontal conveying equipment
(cranes, elevators).

Bei der V/Hz control with slip
compensation can compensate for the
load-dependent speed change in
individual drives (sensorless).

iw

iμ

u1

R'2
s

X'2

i1

Main applications of U/f control:
• pump and fan drives,
• horizontal conveying and
transportation systems,
• multiple motor drives (parallel
operation of several motors at the
variable frequency drive’s output).

R1

Bei der Vector control uses the
variable frequency drive's output
current as a controlled variable. This
makes it possible to perfectly adjust
the three-phase motor in line with the
corresponding torque boost. The
motor speed can be controlled in
connection with an rpm sensor
(tachometer, pulse generator)
(closed loop).

Motor model

Explanation:

Regardless of the control method
used, a variable frequency drive uses
the measured voltage and current
values on the stator winding (u1, i1)
to calculate the required manipulated
variable for flux-generating
component iμ and torque-generating
component in the rotor iw. The motor's
load dependent slip is represented as
resistor R‘2/s. During no-load
operation, this value approaches
infinity (iw → 0). On the other hand, the
value approaches zero as the load
increases. The current in the rotor
grows at this point.

EMC = Electromagnetic
compatibility
EVU = Utility company
IGBT = Insulated-gate bipolar
transistor
PDS = Magnet system
RCD = Residual current device

Technical information concerning braking resistances:
The braking resistors' specified PDB power dissipation applies to
continuous operation.
In short-time operation these values can be increased by multiplying them with the
type-specific power factor using the following formula:
Pmax ≤ (PDB × 100 %) ÷ ED [%]
Pmax = maximum pulse rating
PDB = continuous rating at a duty factor of 100 %
ED = duty factor
tc = Cycle time (max. 120 seconds)
The duty factor is stated as a percentage (%) and is calculated with the formula:
ED [%] = (ED × 100 %) ÷ tc

Pmax

PDB

t [s]

ED
tC (F 120 s)

20
10

6

3.4

PDB
ED

1

1.1

1.25

1.4

1.7

100

90

80

70

60

2

50

2.6

40

30

20

10

5

ED [%]

CA04020001Z-EN-INT

www.eaton.eu

DC1, DA1

General information on Engineering

42

PowerXL™ variable frequency drives
Connection example for DC1

Connecting example for a
0.75 kW motor with
the rating plate illustrated here.

To ensure ideal operational behavior
(e.g., slip compensation, vector
control, etc.), the data on the motor’s
rating plate should be entered into the
variable frequency drive (electric
motor map).

Connection example for DC1

The variable frequency drives are
configured by default in such a way
that they can be operated immediately
with V/Hz control when connected to
the assigned motor rating without
having to configure any additional
parameters.

The following example shows the
necessary parameter settings for a

variable frequency drive (a DC1 in this
example)

P-08

P-07

230/400 V
3.2/1.9 A
cosϕ 0.79
0.75 kW
1410 min -1
50 Hz

P-10

P-09

8

RUN
9

10

11
6 A, 250 VAC
5 A, 30 VDC

7

0V

AI1
DI4

f-Out
+

6

0...+10 V
< 20 mA AO
+24 V DO

5

0V

10 V

4

+10 V Out
< 10 mA

f-Soll
0...+10 V

FF1

DI2

3

DI3
AI2

2

REV

EMC

①

1
+24 V Out
< 100 mA



L1/L L2/N L3

FWD

24 V

3 AC 230 V
3 AC 400/480 V
50/60 Hz

DI1

and connection examples for singlephase and three-phase mains voltages:

VAR

DCDC+

CPU
BR
X1
PIN 8
(PIN2)
PIN 7
(PIN 1)
U

V

RS485

W 

①
PES

FS2, FS3

3 AC 230/400/460 V
M
3~



Block diagram for DC1-32... and DC1-34... with internal radio interference suppression filter
① Only sizes FS2 and FS3 have connection terminals DC+ and BR- for an external braking resistance (optional).
The control signal terminals are
factory set as follows:
1:
24 V: +24 V control voltage,
max. 100 mA
2:
DI1: FWD = Clockwise rotating
field enable (Forward)
3:
DI2: REV = Anticlockwise
rotating field enable (Reverse)
4:
DI3: FF1 = Fixed frequency 1
or AI2
5:
10 V: +10 V reference voltage,
max. 10 mA
6:
AI1: f-setpoint = Frequency
setpoint value (0 - +10 V)
7:
0 V, reference potential
8:
AO: f-Out = Output frequency
to motor (0 - +10 V)
CA04020001Z-EN-INT

www.eaton.eu

9:
0 V, reference potential
10/11: Relay: RUN = Operating signal
(N/O)
DI:
Digital input = +24 VDC digital
input
AI:
Analog input = 0 - 10 V,
0/4 - 20 mA analog input
DO: Digital output = +24 VDC,
max. 20 mA digital output
AO: Analog output = 0 - +10 V,
max. 20 mA analog output
Parameters are used to define the
function and mode of operation for
the digital and analog inputs/outputs.
These parameters are described in
manual MN04020003Z.

PowerXL™ variable frequency drives

43

Connection example for DC1
Connection example for a 0.75 kW motor
Motor: P = 0.75 kW
Mains: 3/N/PE 400 V 50/60 Hz
Connection examples meeting EMC requirements: Power section (see figure below)

Variant A:

The previously indicated 0.75 kW motor can be connected in a delta configuration
for a single-phase 230-V supply system (version A) or in a star configuration for a
400-V supply system (version B).
The frequency inverter and the type-specific accessories are selected
for 1 AC 230 V (DC1-124D3...) or for 3 AC 400 V (MMX34AA2D4) depending on the
mains voltage selected.

Variant B:

Motor in delta configuration
Motor in star configuration
DC1… frequency inverter with single-phase mains supply (230 V)
DC1… frequency inverter with three-phase mains supply (400 V)

1 ∼ 230 V, 50/60 Hz
3 ∼ 400 V, 50/60 Hz

L
N
PE
FAZ-B10/1N

L1
L2
L3
PE

F1

Q1

PKM0-6,3

I

Q1
DILM7
(+DILM12-XP1)

①

U1

V1

W1
PE

R1

2

DX-LN3-004

L1

I

Q11

PE

R1
DX-LN1-009

DILEM-10

1

I

L2/N

U2

V2

W2

PE
L1 L2/N L3

PE

DC1-124D3…
(4.3 A)
W PE

V

U

T1

DC1-342D2…
(2.2 A)
PES

W PE

V

U

T1

PES

PES

X1

PES

PES

X1
PES

PES
PES

M
3~

M1



M
3~

M1


U1

V1

W1

W2 U2

V2

U1

230 V
3.2 A
0.75 kW

V1

W1

W2 U2

V2

400 V
1.9 A
0.75 kW

① Optional connection option for single-phase connections

CA04020001Z-EN-INT

www.eaton.eu

DC1, DA1

Connection example for DC1

44

PowerXL™ variable frequency drives

PowerXL™ variable frequency drives

Assigned switching and protective elements

45

Assigned switching and protective elements

Engineering
Part no.

Motor
Assigned motor
rating 1)
P

P

Rated
motor
current
Ie

kW

HP

A

DC1, DA1

Assigned switching and protective elements

Braking resistances for duty factors (DF) as a %3)

Frequency inverters

Power Wiring

Motor connection

Rated
operational
current2)
Ie

Input current

Protection device

Protection
device

Contactor

Mains choke

Motor choke

Sine filter

10%

20%

40%

A

T

ILN

Ue230 V AC, 1-phase/U2230 V AC, 3-phase
DC1-122D3
0.37
0.5
2

2.3

5

FAZ-B10/1N

-

DILM7

DX-LN1-006

DX-LM3-005

DX-SIN3-004

-

-

-

DC1-124D3

0.75

1

3.2

4.3

8.5

FAZ-B10/1N

-

DILM7

DX-LN1-013

DX-LM3-005

DX-SIN3-010

-

-

-

DC1-127D0

1.5

2

6.3

7

13.9

FAZ-B16/1N

-

DILM7

DX-LN1-018

DX-LM3-008

DX-SIN3-010

DX-BR050-0K4

DX-BR050-0K8

DX-BR047-3K1

DC1-12011

2.2

3

8.7

10.5

19.5

FAZ-B25/1N

-

DILM7

DX-LN1-024

DX-LM3-011

DX-SIN3-016

DX-BR050-0K4

DX-BR050-0K8

DX-BR047-3K1

DC1-12015

4

5

14.8

15

30.5

FAZ-B40/1N

-

DILM7

DX-LN1-032

DX-LM3-016

DX-SIN3-016

DX-BR050-0K4

DX-BR050-0K8

DX-BR047-3K1

Ue230 V AC, 3-phase/U2230 V AC, 3-phase
DC1-322D3
0.37
0.5
2

2.3

3

FAZ-B6/3

PKM0-6,3

DILM7

DX-LN3-004

DX-LM3-005

DX-SIN3-004

-

-

-

DC1-324D3

0.75

1

3.2

4.3

4.5

FAZ-B6/3

PKM0-6,3

DILM7

DX-LN3-006

DX-LM3-005

DX-SIN3-010

-

-

-

DC1-327D0

1.5

2

6.3

7

7.3

FAZ-B10/3

PKM0-10

DILM7

DX-LN3-010

DX-LM3-008

DX-SIN3-010

DX-BR050-0K4

DX-BR050-0K8

DX-BR047-3K1

DC1-32011

2.2

3

8.7

10.5

11

FAZ-B16/3

PKM0-16

DILM7

DX-LN3-016

DX-LM3-011

DX-SIN3-016

DX-BR050-0K4

DX-BR050-0K8

DX-BR047-3K1

DC1-32018

4

5

14.8

18

18.8

FAZ-B20/3

PKM0-20

DILM7

DX-LN3-025

DX-LM3-035

DX-SIN3-023

DX-BR050-0K4

DX-BR050-0K8

DX-BR047-3K1

Ue400 V AC, 3-phase/U2400 V AC, 3-phase
DC1-342D2
0.75
1
1.9

2.2

2.4

FAZ-B6/3

PKM0-6,3

DILM7

DX-LN3-004

DX-LM3-005

DX-SIN3-004

-

-

-

DC1-344D1

1.5

2

3.6

4.1

4.3

FAZ-B6/3

PKM0-6,3

DILM7

DX-LN3-006

DX-LM3-005

DX-SIN3-010

DX-BR100-0K8

DX-BR100-1K6

DX-BR100-6K2

DC1-345D8

2.2

3

5

5.8

6.1

FAZ-B10/3

PKM0-10

DILM7

DX-LN3-010

DX-LM3-008

DX-SIN3-010

DX-BR100-0K8

DX-BR100-1K6

DX-BR100-6K2

DC1-349D5

4

5

8.5

9.5

9.8

FAZ-B16/3

PKM0-16

DILM7

DX-LN3-010

DX-LM3-011

DX-SIN3-010

DX-BR100-0K8

DX-BR100-1K6

DX-BR100-6K2

DC1-34014

5.5

7.5

11.3

14

14.6

FAZ-B20/3

PKM0-20

DILM7

DX-LN3-016

DX-LM3-016

DX-SIN3-016

DX-BR047-3K1

DX-BR047-5K1

DX-BR047-9K2

DC1-34018

7.5

10

15.2

18

18.1

FAZ-B25/3

PKM0-25

DILM7

DX-LN3-025

DX-LM3-035

DX-SIN3-023

DX-BR047-3K1

DX-BR047-5K1

DX-BR047-9K2

DC1-34024

11

15

21.7

24

24.7

FAZ-B32/3

PKM0-32

DILM17

DX-LN3-025

DX-LM3-035

DX-SIN3-023

DX-BR047-3K1

DX-BR047-5K1

DX-BR047-9K2

Ue230 V AC, 1-phase/U2230 V AC, 3-phase
DA1-124D3
0.75
1
3.2

4.3

8.5

FAZ-B10/1N

-

DILM7

DX-LN1-013

DX-LM3-005

DX-SIN3-010

DX-BR100-0K2

DX-BR100-0K4

-

DA1-127D0

1.5

2

6.3

7

13.9

FAZ-B16/1N

-

DILM7

DX-LN1-018

DX-LM3-008

DX-SIN3-010

DX-BR050-0K4

DX-BR050-0K8

-

DA1-12011

2.2

3

8.7

10.5

19.5

FAZ-B25/1N

-

DILM7

DX-LN1-024

DX-LM3-011

DX-SIN3-016

DX-BR050-0K8

DX-BR035-1K1

-

Ue230 V AC, 3-phase/U2230 V AC, 3-phase
DA1-324D3
0.75
1
3.2

4.3

4.5

FAZ-B6/3

PKM0-6,3

DILM7

DX-LN3-006

DX-LM3-005

DX-SIN3-010

DX-BR100-0K2

DX-BR100-0K4

-

DA1-327D0

1.5

2

6.3

7

7.3

FAZ-B10/3

PKM0-10

DILM7

DX-LN3-010

DX-LM3-008

DX-SIN3-010

DX-BR050-0K4

DX-BR050-0K8

-

DA1-32011

2.2

3

8.7

10.5

11

FAZ-B16/3

PKM0-16

DILM7

DX-LN3-016

DX-LM3-011

DX-SIN3-016

DX-BR050-0K8

DX-BR035-1K1

-

DA1-32018

4

5

14.8

18

18.8

FAZ-B20/3

PKM0-20

DILM7

DX-LN3-025

DX-LM3-035

DX-SIN3-023

DX-BR022-1K4

DX-BR022-3K1

-

DA1-32024

5.5

7.5

19.6

24

24.8

FAZ-B32/3

PKM0-32

DILM17

DX-LN3-025

DX-LM3-035

DX-SIN3-032

DX-BR022-1K4

DX-BR022-3K1

-

DA1-32039

7.5

10

26.4

39

40

FAZ-B50/3

-

DILM25

DX-LN3-040

DX-LM3-050

DX-SIN3-048

DX-BR022-1K4

DX-BR022-3K1

-

DA1-32046

11

15

38

46

47.1

FAZ-B63/3

-

DILM40

DX-LN3-050

DX-LM3-050

DX-SIN3-048

DX-BR022-1K4

DX-BR022-3K1

-

DA1-32061

15

20

51

61

62.4

NZMC1-S80

-

DILM50

DX-LN3-080

DX-LM3-063

DX-SIN3-061

DX-BR012-3K1

DX-BR012-5K1

-

DA1-32072

18.5

25

63

72

74.1

NZMC1-S80

-

DILM65

DX-LN3-080

DX-LM3-080

DX-SIN3-072

DX-BR012-3K1

DX-BR012-5K1

-

DA1-32090

22

30

71

90

92.3

NZMC2-S100

-

DILM80

DX-LN3-100

DX-LM3-100

DX-SIN3-090

DX-BR006-5K1

DX-BR006-9K2

-

DA1-32110

30

40

96

110

112.7

NZMC2-S125

-

DILM95

DX-LN3-120

DX-LM3-150

DX-SIN3-115

DX-BR006-5K1

DX-BR006-9K2

-

DA1-32150

45

50

141

150

153.5

NZMC2-S160

-

DILM150

DX-LN3-160

DX-LM3-150

DX-SIN3-150

DX-BR006-5K1

DX-BR006-9K2

-

DA1-32180

55

60

173

180

183.8

NZMC2-S200

-

DILM170

DX-LN3-200

DX-LM3-180

DX-SIN3-180

DX-BR006-5K1

DX-BR006-9K2

-

DA1-32202

55

75

173

202

206.2

NZMC3-S250

-

DILM185A

DX-LN3-250

DX-LM3-220

DX-SIN3-250

DX-BR006-5K1

DX-BR006-9K2

-

DA1-32248

75

100

233

248

252.8

NZMC3-S320

-

DILM185A

DX-LN3-300

DX-LM3-260

DX-SIN3-250

DX-BR006-5K1

DX-BR006-9K2

-

1) Assigned

motor rating for normal internally and externally ventilated four-pole, three-phase
asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz)
a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0
3) Only for devices with an internal braking chopper
2) With

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

PowerXL™ variable frequency drives

Assigned switching and protective elements

Part no.

Motor

Braking resistances for duty factors (DF) as a %3)

Frequency inverters

Power Wiring

Rated
operational
current2)
Ie

Input current

Protection device

Protection
device

Contactor

Mains choke

Motor choke

Sine filter

10%

20%

40%

A

T

Ue400 V AC, 3-phase/U2400 V AC, 3-phase
DA1-342D2
0.75
1
1.9

2.2

2.4

FAZ-B6/3

PKM0-6,3

DILM7

DX-LN3-004

DX-LM3-005

DX-SIN3-004

DX-BR400-0K4

DX-BR400-0K4

-

DA1-344D1

1.5

2

3.6

4.1

4.3

FAZ-B6/3

PKM0-6,3

DILM7

DX-LN3-006

DX-LM3-005

DX-SIN3-010

DX-BR200-0K4

DX-BR200-0K8

-

DA1-345D8

2.2

3

5

5.8

6.1

FAZ-B10/3

PKM0-10

DILM7

DX-LN3-010

DX-LM3-008

DX-SIN3-010

DX-BR150-0K5

DX-BR150-1K4

-

DA1-349D5

4

5

8.5

9.5

9.8

FAZ-B16/3

PKM0-16

DILM7

DX-LN3-010

DX-LM3-011

DX-SIN3-010

DX-BR100-0K8

DX-BR100-1K4

-

DA1-34014

5.5

7.5

11.3

14

14.6

FAZ-B20/3

PKM0-20

DILM7

DX-LN3-016

DX-LM3-016

DX-SIN3-016

DX-BR075-1K4

DX-BR075-5K1

-

DA1-34018

7.5

10

15.2

18

18.1

FAZ-B25/3

PKM0-25

DILM7

DX-LN3-025

DX-LM3-035

DX-SIN3-023

DX-BR050-3K1

DX-BR050-5K1

-

DA1-34024

11

15

21.7

24

24.7

FAZ-B32/3

PKM0-32

DILM17

DX-LN3-025

DX-LM3-035

DX-SIN3-023

DX-BR040-3K1

DX-BR040-5K1

-

DA1-34030

15

20

29.3

30

30.8

FAZ-B40/3

-

DILM17

DX-LN3-040

DX-LM3-035

DX-SIN3-032

DX-BR022-5K1

DX-BR022-9K2

-

DA1-34039

18.5

25

36

39

40

FAZ-B50/3

-

DILM25

DX-LN3-040

DX-LM3-050

DX-SIN3-048

DX-BR022-5K1

DX-BR022-9K2

-

DA1-34046

22

30

41

46

47.1

FAZ-B63/3

-

DILM40

DX-LN3-050

DX-LM3-050

DX-SIN3-048

DX-BR022-5K1

DX-BR022-9K2

-

DA1-34061

30

40

55

61

62.8

NZMC1-S80

-

DILM50

DX-LN3-080

DX-LM3-063

DX-SIN3-061

DX-BR012-9K2

DX-BR012-18K1

-

DA1-34072

37

50

68

72

73.8

NZMC1-S80

-

DILM65

DX-LN3-080

DX-LM3-080

DX-SIN3-090

DX-BR012-9K2

DX-BR012-18K1

-

DA1-34090

45

60

81

90

92.2

NZMC1-S100

-

DILM80

DX-LN3-100

DX-LM3-100

DX-SIN3-115

DX-BR006-18K1

DX-BR006-33K3

-

DA1-34110

55

75

99

110

112.5

NZMC2-S125

-

DILM95

DX-LN3-120

DX-LM3-150

DX-SIN3-115

DX-BR006-18K1

DX-BR006-33K3

-

DA1-34150

75

100

134

150

153.2

NZMC2-S160

-

DILM150

DX-LN3-160

DX-LM3-150

DX-SIN3-150

DX-BR006-18K1

DX-BR006-33K3

-

DA1-34180

90

150

161

180

183.7

NZMC2-S200

-

DILM170

DX-LN3-200

DX-LM3-180

DX-SIN3-180

DX-BR006-18K1

DX-BR006-33K3

-

DA1-34202

110

175

196

202

205.9

NZMC3-S250

-

DILM185A

DX-LN3-250

DX-LM3-220

DX-SIN3-250

DX-BR006-18K1

DX-BR006-33K3

-

DA1-34240

132

200

231

240

244.5

NZMC3-S320

-

DILM185A

DX-LN3-250

DX-LM3-260

DX-SIN3-250

DX-BR006-18K1

DX-BR006-33K3

-

DA1-34302

160

250

279

302

307.8

NZMC3-S400

-

DILM225A

DX-LN3-370

DX-LM3-303

DX-SIN3-440

DX-BR006-18K1

DX-BR006-33K3

-

DA1-34370

200

300

349

370

-

NZMC3-S400

-

-

-

-

-

DX-BR002-54K3

DX-BR002-102K4

-

DA1-34450

250

350

437

450

-

NZMC3-S500

-

-

-

-

-

DX-BR002-54K3

DX-BR002-102K4

-

Assigned motor
rating 1)
P

P

Rated
motor
current
Ie

kW

HP

A

47

Assigned switching and protective elements

Motor connection

DC1, DA1

46

ILN

1) Assigned

motor rating for normal internally and externally ventilated four-pole, three-phase
asynchronous motors with 1500 rpm (at 50 Hz) or 1800 rpm (at 60 Hz)
2) With a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0
3) Only for devices with an internal braking chopper

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

48

PowerXL™ variable frequency drives

PowerXL™ variable frequency drives

DC1 (U
(Ue:
115 VV AC,
AC, single-phase,
single-phase, UU2:
115VVAC,
AC,single-phase/230
single-phase/230VVAC,
AC,33phase)
phase)
e: 115
2: 115

49

DC1 (Ue: 115 V AC,DC1
single-phase,
V AC, single-phase/230
AC, 3 phase)
(Ue: 230 VUAC,
single-phase,
U2: 230 V AC,Vsingle-phase)
2: 115

DC1 (Ue: 115 V AC, single-phase, U2: 115 V AC, single-phase/230 V AC, 3 phase)DC1 (Ue: 230 V AC, single-phase, U2: 230 V AC, single-phase)

DC1-S1011…

DC1-1D2D3…

DC1-1D4D3…

DC1-1D5D3…

DC1-S24D3…

DC1-S27D0…

DC1, DA1

DC1-S17D0…
General
Climatic proofing

ρw

%

Mounting position
Altitude

m

Protection against direct contact

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

Vertical

Vertical

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.

C1, C2, C3, depending on the motor cable length, the connected load, and
ambient conditions. External radio interference suppression filters (optional)
may be necessary.
1st and 2nd environments

Radio interference level
Radio interference class (EMC)

Environment (EMC)

1st and 2nd environments

longest permissible length of motor cable

I

m

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

-

-

Main circuit
Supply
Rated operational voltage

Ue

115 V AC, single-phase

Notes

-

-

230 V AC, 1-phase
The mains voltage of 115 V is raised to 230 V (output
voltage) through an internal voltage double connection.

-

Mains voltage (50/60Hz)

ULN

V

110 (-10%) - 115 (+10%)

Input current

ILN

T

8.5

12.5

11

19

25

6

9.3

14

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

Mains switch-on frequency

200 (-10%) - 240 (+10%)

Maximum of one time every 30 seconds

Maximum of one time every 30 seconds

Maximum of one time every 30 seconds

Power section
Overload current for 60 s every 600 s

IL

A

10.5

15.75

3.45

6.45

8.7

6.45

10.5

15.75

Starting current for 2 s

IL

A

12.25

18.38

4.03

7.53

10.15

7.53

12.25

18.38

Output voltage with Ve

U2

Output Frequency

f2

Switching frequency

115 V AC, single-phase

230 V AC, 3-phase

230 V AC, single-phase

230 V AC, single-phase

230 V AC, single-phase

Hz

0 - 50 Hz (max. 120 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 120 Hz)

0 - 50 Hz (max. 120 Hz)

0 - 50 Hz (max. 120 Hz)

fPWM

kHz

16
(adjustable 4 - 32)

Δf

Hz

0.1

0.1

0.1

16
(adjustable 4 - 32)
U/f control
Slip compensation
0.1

16
(adjustable 4 - 32)

Frequency resolution (setpoint value)

16
(adjustable 4 - 32)
U/f control
Slip compensation
0.1
0.1

0.1

0.1

Rated operational current

Ie

A

7

10.5

2.3

4.3

5.8

4.3

7

10.5

PV

W

18.5

22

18.5

37.5

44

18.5

37.5

44

η

%

95

96

95

95

96

95

95

96

IPE

mA

2.49

2.49

<1

<1

<1

2.49

2.49

2.49

FS1

FS2

FS1

FS1

FS2

FS1

FS1

FS2

Operation Mode

Power loss
Heat dissipation at rated operational
current
Efficiency
Maximum leakage current to ground (PE)
without motor
Frame size
Motor feeder
Assigned motor rating
at 115 V, 50 Hz

P

kW

0.37

0.55

-

-

-

-

-

-

at 230 V, 50 Hz

P

kW

-

-

0.37

0.75

1.1

-

-

-

110 - 120 V, 60 Hz

P

HP

0.5

0.75

-

-

-

-

-

-

at 220 - 240 V, 60 Hz

P

HP

-

-

0.5

1

1.5

-

-

-

Apparent power at rated operation 230 V

S

kVA

0

0

-

-

-

0.99

1.61

2.42

Apparent power at rated operation 240 V

S

kVA

0

0

-

-

-

1.03

1.68

2.52

Standard braking torque

-

-

max. 30% MN

max. 30% MN

max. 30% MN

-

-

-

DC braking torque

max. 100% of rated operational current Ie, variable

Braking torque with external braking
resistance

-

Apparent power

Braking function
max. 100% of rated operational current Ie, variable

minimum external braking resistance

Rmin

Ω

-

max. 100% rated
operational
current Ie, with
external braking
resistance
47

-

-

-

-

max. 100% rated
operational
current Ie, with
external braking
resistance
47

-

-

max. 100% rated
operational current Ie,
with external braking
resistance

-

-

47

Switch-on threshold for the braking
transistor
DC braking

UDC

V

-

-

-

-

390 V DC

-

-

390 V DC

%

I/Ie

-

-

-

-

-

-

-

-

Braking torque

%

I/Ie

-

-

-

-

-

-

-

-

External control voltage

Uc

V

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

Reference voltage

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

Control section

Note
CA04020001Z-EN-INT

1) With

a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

50

PowerXL™ variable frequency drives

PowerXL™ variable frequency drives

DC1 (U
(Ue:
230 VV AC,
AC, single-phase,
single-phase, UU2:
230VVAC,
AC,33phase)
phase)
e: 230
2: 230

51

DC1DC1
(Ue:(Ue:
230 230
V AC,V single-phase,
U2: 230 V AC, 3 phase)
AC, 3 phase, U2:

DC1 (Ue: 230 V AC, single-phase, U2: 230 V AC, 3 phase)DC1 (Ue: 230 V AC, 3 phase, U2: 230 V AC, 3 phase)

DC1-122D3…

DC1-124D3…

DC1-127D0…

DC1-12011…

DC1-12015…

DC1-322D3…

DC1-324D3…

DC1-327D0…

DC1-32011…

DC1-32018…

DC1, DA1

Part no.
General
Climatic proofing

ρw

%

Mounting position
Altitude

m

Protection against direct contact

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

Vertical

Vertical

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

Radio interference level
Radio interference class (EMC)
Environment (EMC)
longest permissible length of motor cable

I

m

25 (200)

25 (200)

25 (200)

25 (200)

Main circuit
Supply
Rated operational voltage

Ue

230 V AC, 1-phase

230 V AC, 3-phase

Mains voltage (50/60Hz)

ULN

V

200 (-10%) - 240 (+10%)

200 (-10%) - 240 (+10%)

Input current

ILN

T

5

8.5

13.9

19.5

30.5

3

4.5

7.3

11

18.8

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

Mains switch-on frequency

Maximum of one time every 30 seconds

Maximum of one time every 30 seconds

Power section
Overload current for 60 s every 600 s

IL

A

3.45

6.45

10.5

15.75

22.5

3.45

6.45

10.5

15.75

27

Starting current for 2 s

IL

A

4.03

7.53

12.25

18.38

26.25

4.03

7.53

12.25

18.38

31.5

Output voltage with Ve

U2

Output Frequency

f2

Hz

Switching frequency

fPWM

kHz

0 - 50 Hz
(max. 500 Hz)
16
(adjustable 4 - 32)

0 - 50 Hz
(max. 500 Hz)
16
(adjustable 4 - 32)

0 - 50 Hz
(max. 500 Hz)
16
(adjustable 4 - 32)

0 - 50 Hz
(max. 500 Hz)
8
(adjustable 4 - 24)

Frequency resolution (setpoint value)

Δf

Rated operational current

Ie

230 V AC, 3-phase

230 V AC, 3-phase
0 - 50 Hz
(max. 500 Hz)

0 - 50 Hz
(max. 500 Hz)

0 - 50 Hz
(max. 500 Hz)
8
(adjustable 4 - 24)

Hz

0 - 50 Hz
0 - 50 Hz
(max. 500 Hz)
(max. 500 Hz)
16
(adjustable 4 - 32)
U/f control
Slip compensation
0.1
0.1

0.1

0.1

0.1

0 - 50 Hz
(max. 500 Hz)
16
(adjustable 4 - 32)
U/f control
Slip compensation
0.1

0.1

0.1

0.1

0.1

A

2.3

4.3

7

10.5

15

2.3

4.3

7

10.5

18

PV

W

18.5

45.75

63

103.4

160

14.8

39.75

61.5

90.2

160

η

%

95

93.9

95.8

95.3

96

96

94.7

95.9

95.9

96

IPE

mA

2.49

2.49

2.49

2.49

<1

<1

<1

<1

<1

<1

FS1

FS1

FS2

FS2

FS3

FS1

FS1

FS2

FS2

FS3

Operation Mode

Power loss
Heat dissipation at rated operational
current
Efficiency
Maximum leakage current to ground (PE)
without motor
Frame size
Motor feeder
Assigned motor rating
at 230 V, 50 Hz

P

kW

0.37

0.75

1.5

2.2

4

0.37

0.75

1.5

2.2

4

at 220 - 240 V, 60 Hz

P

HP

0.5

1

2

3

5

0.5

1

2

3

5

Apparent power
Apparent power at rated operation 230 V

S

kVA

0.92

1.71

2.79

4.18

5.98

0.92

1.71

2.79

4.18

7.17

Apparent power at rated operation 240 V

S

kVA

0.96

1.79

2.91

4.36

6.24

0.96

1.79

2.91

4.36

7.48

Standard braking torque

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

DC braking torque

max. 100% of rated operational current Ie, variable

Braking torque with external braking
resistance

-

-

max. 100% rated operational current Ie, with external
braking resistance

-

max. 100% rated operational
current Ie, with external braking
resistance
47

max. 100% rated operational
current Ie, with external braking
resistance
47

Braking function
max. 100% of rated operational current Ie, variable

minimum external braking resistance

Rmin

Ω

-

-

100

47

47

-

max. 100% rated operational
current Ie, with external braking
resistance
100

Switch-on threshold for the braking
transistor
DC braking

UDC

V

-

-

390 V DC

390 V DC

390 V DC

-

390 V DC

390 V DC

390 V DC

%

I/Ie

-

-

-

-

-

-

-

-

-

Braking torque

%

I/Ie

-

-

-

-

-

-

-

-

-

External control voltage

Uc

V

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

Reference voltage

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

Control section

Note

CA04020001Z-EN-INT

1) With

a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

52

PowerXL™ variable frequency drives

PowerXL™ variable frequency drives

DC1 (U
(Ue:
400 VV AC,
AC, 33 phase,
phase, UU2:
400VVAC,
AC,33phase)
phase)
e: 400
2: 400

53

DC1(Ue:
(Ue: 400
400 VV AC,
AC, 33 phase,
phase, U2:
U2: 400 V AC, 3 phase)
DC1

DC1 (Ue: 400 V AC, 3 phase, U2: 400 V AC, 3 phase)DC1 (Ue: 400 V AC, 3 phase, U2: 400 V AC, 3 phase)

DC1-342D2…

DC1-344D1…

DC1-345D8…

DC1-349D5…

DC1-34014…

DC1-34018…

DC1-34024…

DC1, DA1

Part no.
General
Climatic proofing

ρw

%

Mounting position
Altitude

m

Protection against direct contact

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

Vertical

Vertical

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

380 (-10%) - 480
(+10%)
4.3

380 (-10%) - 480
(+10%)
6.1

380 (-10%) - 480
(+10%)
9.8

380 (-10%) - 480 (+10%)

380 (-10%) - 480 (+10%)

380 (-10%) - 480 (+10%)

Radio interference level
Radio interference class (EMC)
Environment (EMC)
longest permissible length of motor cable

I

m

Main circuit
Supply
Rated operational voltage

Ue

Mains voltage (50/60Hz)

ULN

V

Input current

ILN

T

380 (-10%) - 480
(+10%)
2.4

14.6

18.1

24.7

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

Mains switch-on frequency

Maximum of one time every 30 seconds

Maximum of one time every 30 seconds

Power section
Overload current for 60 s every 600 s

IL

A

3.3

6.15

8.7

14.25

21

27

36

Starting current for 2 s

IL

A

3.85

7.18

10.15

16.63

24.5

31.5

42

Output voltage with Ve

U2

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

Output Frequency

f2

Hz

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

Switching frequency

fPWM

kHz

16
(adjustable 4 - 32)

16
(adjustable 4 - 32)

16
(adjustable 4 - 32)

8
(adjustable 4 - 24)

Δf

Hz

0.1

0.1

0.1

8
(adjustable 4 - 24)
U/f control
Slip compensation
0.1

8
(adjustable 4 - 24)

Frequency resolution (setpoint value)

16
(adjustable 4 - 32)
U/f control
Slip compensation
0.1

0.1

0.1

Rated operational current

Ie

A

2.2

4.1

5.8

9.5

14

18

24

Heat dissipation at rated operational
current
Efficiency

PV

W

63.75

76.5

101.2

136

209

300

297

η

%

91.5

94.9

95.4

96.6

96.2

97

97.3

Maximum leakage current to ground (PE)
without motor
Frame size

IPE

mA

<1

<1

<1

<1

<1

<1

2.49

FS1

FS2

FS2

FS2

FS3

FS3

FS3

Operation Mode

Power loss

Motor feeder
Assigned motor rating
at 400 V, 50 Hz

P

kW

0.75

1.5

2.2

4

5.5

7.5

11

at 440 - 480 V, 60 Hz

P

HP

1

2

3

5

7.5

10

15

Apparent power at rated operation 400 V

S

kVA

1.52

2.84

4.02

6.58

9.67

12.47

16.63

Apparent power at rated operation 480 V

S

kVA

1.83

3.41

4.82

7.9

11.64

14.96

19.95

Standard braking torque

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

DC braking torque

max. 100% of rated operational current Ie, variable

max. 100% of rated operational current Ie, variable

Braking torque with external braking
resistance
minimum external braking resistance

-

max. 100% rated operational current Ie, with external braking resistance

max. 100% rated operational current Ie, with external braking resistance

Apparent power

Braking function

Switch-on threshold for the braking
transistor
DC braking
Braking torque
External control voltage
Reference voltage

Rmin

Ω

-

200

200

100

100

47

47

UDC

V

-

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

%

I/Ie

-

-

-

-

-

-

-

%

I/Ie

-

-

-

-

-

-

-

Uc

V

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

Control section

Note

CA04020001Z-EN-INT

1) With

a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

54

PowerXL™ variable frequency drives

PowerXL™ variable frequency drives

DA1 (U
phase)
(Ue:
230 VV AC,
AC, single-phase,
single-phase, UU2:
230VVAC,
AC,3single-phase)
e: 230
2: 230

55

DA1(Ue:
(Ue: 230
230 VV AC,
AC, 33 phase,
phase, U2:
U2: 230 V AC, 3 phase)
DA1

DA1 (Ue: 230 V AC, single-phase, U2: 230 V AC, single-phase)DA1 (Ue: 230 V AC, 3 phase, U2: 230 V AC, 3 phase)

DA1-124D3…

DA1-127D0…

DA1-12011…

DA1-324D3…

DA1-327D0…

DA1-32011…

DA1-32018…

DA1-32024…

DC1, DA1

Typ
General
Climatic proofing

ρw

%

Mounting position
Altitude

m

Protection against direct contact

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

Vertical

Vertical

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

230 V AC, 1-phase

230 V AC, 1-phase

230 V AC, 1-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

Radio interference level
Radio interference class (EMC)
Environment (EMC)
longest permissible length of motor cable

I

m

Main circuit
Supply
Rated operational voltage

Ue

Mains voltage (50/60Hz)

ULN

V

200 (-10%) - 240 (+10%)

200 (-10%) - 240 (+10%)

Input current

ILN

T

8.5

13.9

19.5

4.5

7.3

11

18.8

24.8

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

Mains switch-on frequency

Maximum of one time every 30 seconds

Maximum of one time every 30 seconds

Power section
Overload current for 60 s every 600 s

IL

A

6.45

10.5

15.75

6.45

10.5

15.75

27

36

Starting current for 4 s

IL

A

8.6

14

21

8.6

14

21

36

48

Output voltage with Ve

U2

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

Output Frequency

f2

Hz

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

Switching frequency

fPWM

kHz

16
(adjustable 4 - 32)

16
(adjustable 4 - 24)

16
(adjustable 4 - 16)

Δf

Hz

0.1

16
16
(adjustable 4 - 32)
(adjustable 4 - 32)
U/f control
Slip compensation
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.1
0.1

16
(adjustable 4 - 32)

Frequency resolution (setpoint value)

16
16
(adjustable 4 - 32)
(adjustable 4 - 32)
U/f control
Slip compensation
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.1
0.1

0.1

0.1

0.1

Rated operational current

Ie

A

4.3

7

10.5

4.3

7

10.5

18

24

PV

W

45.75

63

103.4

39.75

61.5

90.2

160

170.5

η

%

93.9

95.8

95.3

94.7

95.9

95.9

96

96.9

IPE

mA

2.49

2.49

2.49

1.73

1.73

1.73

0.93

0.93

FS2

FS2

FS2

FS2

FS2

FS2

FS3

FS3

Operation Mode

Power loss
Heat dissipation at rated operational
current
Efficiency
Maximum leakage current to ground (PE)
without motor
Frame size
Motor feeder
Assigned motor rating
at 230 V, 50 Hz

P

kW

0.75

1.5

2.2

0.75

1.5

2.2

4

5.5

at 220 - 240 V, 60 Hz

P

HP

1

2

3

1

2

3

5

7.5

Apparent power
Apparent power at rated operation 230 V

S

kVA

1.71

2.79

4.18

1.71

2.79

4.18

7.17

9.56

Apparent power at rated operation 240 V

S

kVA

1.79

2.91

4.36

1.79

2.91

4.36

7.48

9.98

Standard braking torque

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

DC braking torque

max. 100% of rated operational current Ie, variable

max. 100% of rated operational current Ie, variable

Braking torque with external braking
resistance
minimum external braking resistance

max. 100% rated operational current Ie, with external braking resistance

max. 100% rated operational current Ie, with external braking resistance

Braking function

Rmin

Ω

100

50

35

100

50

35

20

20

UDC

V

390 V DC

390 V DC

390 V DC

390 V DC

390 V DC

390 V DC

390 V DC

390 V DC

External control voltage

Uc

V

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

Reference voltage

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

Switch-on threshold for the braking
transistor
Control section

Note

CA04020001Z-EN-INT

1) With

a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

56

PowerXL™ variable frequency drives

PowerXL™ variable frequency drives

DA1 (U
(Ue:
400 VV AC,
AC, 33 phase,
phase, UU2:
400VVAC,
AC,33phase)
phase)
e: 400
2: 400

57

DA1(Ue:
(Ue: 400
400 VV AC,
AC, 33 phase,
phase, U2:
U2: 400 V AC, 3 phase)
DA1

DA1 (Ue: 400 V AC, 3 phase, U2: 400 V AC, 3 phase)DA1 (Ue: 400 V AC, 3 phase, U2: 400 V AC, 3 phase)

DA1-342D2…

DA1-344D1FB…

DA1-345D8…

DA1-349D5…

DA1-34014…

DA1-34018…

DA1-34024…

DA1-34030…

DA1-34039…

DA1-34046…

DC1, DA1

Part no.
General
Climatic proofing

ρw

%

Mounting position
Altitude

m

Protection against direct contact

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

Vertical

Vertical

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

Radio interference level
Radio interference class (EMC)
Environment (EMC)
longest permissible length of motor cable

I

m

Main circuit
Supply
Rated operational voltage

Ue

Mains voltage (50/60Hz)

ULN

V

380 (-10%) - 480 (+10%)

Input current

ILN

T

2.4

4.3

6.1

9.8

14.6

18.1

24.7

30.8

40

47.1

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

Mains switch-on frequency

380 (-10%) - 480 (+10%)

Maximum of one time every 30 seconds

Maximum of one time every 30 seconds

Power section
Overload current for 60 s every 600 s

IL

A

3.3

6.15

8.7

14.25

21

27

36

45

58.5

69

Starting current for 4 s

IL

A

4.4

8.2

11.6

19

28

36

48

60

78

92

Output voltage with Ve

U2

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

Output Frequency

f2

Hz

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

Switching frequency

fPWM

kHz

8
(adjustable 4 - 32)

8
(adjustable 4 - 32)

8
(adjustable 4 - 24)

8
(adjustable 4 - 24)

8
(adjustable 4 - 24)

Δf

Hz

0.1

0.1

8
8
(adjustable 4 - 24)
(adjustable 4 - 24)
U/f control
Slip compensation
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.1
0.1

8
(adjustable 4 - 24)

Frequency resolution (setpoint value)

8
8
(adjustable 4 - 24)
(adjustable 4 - 24)
U/f control
Slip compensation
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.1
0.1

0.1

0.1

0.1

0.1

Rated operational current

Ie

A

2.2

4.1

5.8

9.5

14

18

24

30

39

46

PV

W

63.75

76.5

101.2

136

209

300

297

375

444

506

η

%

91.5

94.9

95.4

96.6

96.2

97

97.3

97.5

97.6

97.7

IPE

mA

4.65

4.65

4.65

4.65

1.55

1.55

2.47

2.47

2.47

2.47

FS2

FS2

FS2

FS2

FS3

FS3

FS4

FS4

FS4

FS4

Operation Mode

Power loss
Heat dissipation at rated operational
current
Efficiency
Maximum leakage current to ground (PE)
without motor
Frame size
Motor feeder
Assigned motor rating
at 400 V, 50 Hz

P

kW

0.75

1.5

2.2

4

5.5

7.5

11

15

18.5

22

at 440 - 480 V, 60 Hz

P

HP

1

2

3

5

7.5

10

15

20

25

30

Apparent power
Apparent power at rated operation 400 V

S

kVA

1.52

2.84

4.02

6.58

9.67

12.47

16.63

20.78

27.02

31.87

Apparent power at rated operation 480 V

S

kVA

1.83

3.41

4.82

7.9

11.64

14.96

19.95

24.94

32.42

38.24

Standard braking torque

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

DC braking torque

max. 100% of rated operational current Ie, variable

max. 100% of rated operational current Ie, variable

Braking torque with external braking
resistance
minimum external braking resistance

max. 100% rated operational current Ie, with external braking resistance

max. 100% rated operational current Ie, with external braking resistance

Braking function

Rmin

Ω

400

200

150

100

75

50

40

22

22

22

UDC

V

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

External control voltage

Uc

V

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

Reference voltage

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

Switch-on threshold for the braking
transistor
Control section

Note

CA04020001Z-EN-INT

1) With

a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

58

PowerXL™ variable frequency drives

PowerXL™ variable frequency drives

DA1 (U
(Ue:
230 VV AC,
AC, 33 phase,
phase, UU2:
230VVAC,
AC,33phase)
phase)
e: 400
2: 400

59

DA1(Ue:
(Ue: 230
400 VV AC,
AC, 33 phase,
phase, U2:
U2: 230
400 V AC, 3 phase)
DA1

DA1 (Ue: 230 V AC, 3 phase, U2: 230 V AC, 3 phase)DA1 (Ue: 230 V AC, 3 phase, U2: 230 V AC, 3 phase)

DA1-34090…

DC1, DA1

Part no.
General
Climatic proofing

ρw

%

Mounting position
Altitude

m

Protection against direct contact

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

Vertical

Vertical

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

Radio interference level
Radio interference class (EMC)
Environment (EMC)
longest permissible length of motor cable

I

m

Main circuit
Supply
Rated operational voltage

Ue

Mains voltage (50/60Hz)

ULN

V

380 (-10%) - 480 (+10%)

Input current

ILN

T

62.8

73.8

92.2

112.5

153.2

183.7

205.9

244.5

307.8

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

Mains switch-on frequency

380 (-10%) - 480 (+10%)

Maximum of one time every 30 seconds

Maximum of one time every 30 seconds

Power section
Overload current for 60 s every 600 s

IL

A

91.5

105

135

165

225

270

303

360

453

Starting current for 4 s

IL

A

122

140

180

220

300

360

404

480

604

Output voltage with Ve

U2

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

Output Frequency

f2

Hz

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

0 - 50 Hz (max. 500 Hz)

Switching frequency

fPWM

kHz

4
(adjustable 4 - 16)

4
(adjustable 4 - 16)

4
(adjustable 4 - 12)

4
(adjustable 4 - 8)

Δf

Hz

0.1

0.1

4
4
(adjustable 4 - 12)
(adjustable 4 - 8)
U/f control
Slip compensation
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.1
0.1

4
(adjustable 4 - 16)

Frequency resolution (setpoint value)

8
8
(adjustable 4 - 24)
(adjustable 4 - 24)
U/f control
Slip compensation
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.1
0.1

0.1

0.1

0.1

Rated operational current

Ie

A

61

72

90

110

150

180

202

240

302

PV

W

840

925

1080

1210

1575

1800

2090

2376

3040

η

%

97.2

97.5

97.6

97.8

97.9

98

98.1

98.2

98.1

IPE

mA

0.49

0.49

2.68

2.68

2.68

2.68

4.75

4.75

4.75

FS5

FS5

FS6

FS6

FS6

FS6

FS7

FS7

FS7

Operation Mode

Power loss
Heat dissipation at rated operational
current
Efficiency
Maximum leakage current to ground (PE)
without motor
Frame size
Motor feeder
Assigned motor rating
at 400 V, 50 Hz

P

kW

30

37

45

55

75

90

110

132

160

at 440 - 480 V, 60 Hz

P

HP

40

50

60

75

100

150

175

200

250

Apparent power
Apparent power at rated operation 400 V

S

kVA

42.26

48.5

62.35

76.21

103.92

124.71

139.95

166.28

209.23

Apparent power at rated operation 480 V

S

kVA

50.71

58.2

74.82

91.45

124.71

149.65

167.94

199.53

251.08

Standard braking torque

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

DC braking torque

max. 100% of rated operational current Ie, variable

max. 100% of rated operational current Ie, variable

Braking torque with external braking
resistance
minimum external braking resistance

max. 100% rated operational current Ie, with external braking resistance

max. 100% rated operational current Ie, with external braking resistance

Braking function

Rmin

Ω

12

12

6

6

6

6

6

6

6

UDC

V

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

780 V DC

External control voltage

Uc

V

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

Reference voltage

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

Switch-on threshold for the braking
transistor
Control section

Note

CA04020001Z-EN-INT

1) With

a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

60

PowerXL™ variable frequency drives

PowerXL™ variable frequency drives

DA1 (U
(Ue:
230 VV AC,
AC, 33 phase,
phase, UU2:
230VVAC,
AC,33phase)
phase)
e: 230
2: 230

DA1-32039…

DA1-32046…

DA1-32061…

DA1-32072…

DA1-32090…

DA1-32110…

DA1-32150…

DA1-32180…

DA1-32202…

DA1-32248…

DC1, DA1

Typ

61

DA1(Ue:
(Ue: 230
230 VV AC,
AC, 33 phase,
phase, U2:
U2: 230 V AC, 3 phase)
DA1

General
Climatic proofing

ρw

%

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

< 95 %, average relative humidity (RH), non-condensing (EN 50178)

Vertical

Vertical

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 4000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

C1, C2, C3, depending on the motor cable length, the connected load, and ambient conditions.
External radio interference suppression filters (optional) may be necessary.
1st and 2nd environments

m

25 (200)

Mounting position
Altitude

m

Protection against direct contact
Radio interference level
Radio interference class (EMC)
Environment (EMC)
longest permissible length of motor cable

I

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

25 (200)

230 V AC,
3-phase

230 V AC,
3-phase

230 V AC,
3-phase

230 V AC,
3-phase
200 (-10%) - 240 (+10%)

230 V AC,
3-phase

230 V AC,
3-phase

230 V AC,
3-phase

230 V AC,
3-phase

Main circuit
Supply
Rated operational voltage

Ue

Mains voltage (50/60Hz)

ULN

V

230 V AC,
230 V AC,
3-phase
3-phase
200 (-10%) - 240 (+10%)

Input current

ILN

T

40

47.1

62.4

74.1

92.3

112.7

153.5

183.8

206.2

252.8

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

48 - 62 Hz

Mains switch-on frequency

Maximum of one time every 30 seconds

Maximum of one time every 30 seconds

Power section
Overload current for 60 s every 600 s

IL

A

45

69

91.5

108

135

165

225

270

303

372

Starting current for 4 s

IL

A

60

92

122

144

180

220

300

360

404

496

Output voltage with Ve

U2

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

230 V AC, 3-phase

Output Frequency

f2

Hz

Switching frequency

fPWM

kHz

0 - 50 Hz
(max. 500 Hz)
4
(adjustable 4 - 8)

0 - 50 Hz
(max. 500 Hz)
4
(adjustable 4 - 16)

0 - 50 Hz
(max. 500 Hz)
4
(adjustable 4 - 12)

Frequency resolution (setpoint value)

Δf

Rated operational current

Ie

230 V AC, 3-phase
0 - 50 Hz
(max. 500 Hz)

0 - 50 Hz
(max. 500 Hz)

0 - 50 Hz
(max. 500 Hz)
4
(adjustable 4 - 16)

Hz

0 - 50 Hz
0 - 50 Hz
(max. 500 Hz)
(max. 500 Hz)
8
(adjustable 4 - 24)
U/f control
Slip compensation
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.1
0.1

0.1

0.1

0.1

0 - 50 Hz
0 - 50 Hz
(max. 500 Hz)
(max. 500 Hz)
4
4
(adjustable 4 - 16)
(adjustable 4 - 12)
U/f control
Slip compensation
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.1
0.1

0.1

0.1

0.1

A

39

46

61

72

90

110

150

180

202

248

PV

W

187.5

264

345

518

550

720

814

945

1100

1425

η

%

97.5

97.6

97.7

97.2

97.5

97.6

97.8

97.9

98

98.1

IPE

mA

1.42

1.42

0.28

0.28

1.54

1.54

1.54

1.54

2.74

2.74

FS4

FS4

FS5

FS5

FS6

FS6

FS6

FS6

FS7

FS7

Operation Mode

Power loss
Heat dissipation at rated operational
current
Efficiency
Maximum leakage current to ground (PE)
without motor
Frame size
Motor feeder
Assigned motor rating
at 230 V, 50 Hz

P

kW

7.5

11

15

18.5

22

30

45

55

55

75

at 220 - 240 V, 60 Hz

P

HP

10

15

20

25

30

40

50

60

75

100

Apparent power
Apparent power at rated operation 230 V

S

kVA

11.95

18.33

24.3

28.68

35.85

43.82

59.76

71.71

80.47

98.8

Apparent power at rated operation 240 V

S

kVA

12.47

19.12

25.36

29.93

37.41

45.73

62.35

74.82

83.97

103.09

Standard braking torque

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

max. 30% MN

DC braking torque

max. 100% of rated operational current Ie, variable

max. 100% of rated operational current Ie, variable

Braking torque with external braking
resistance
minimum external braking resistance

max. 100% rated operational current Ie, with external braking resistance

max. 100% rated operational current Ie, with external braking resistance

Braking function

Rmin

Ω

22

12

12

6

6

6

6

6

6

6

UDC

V

390 V DC

390 V DC

390 V DC

390 V DC

390 V DC

390 V DC

390 V DC

390 V DC

390 V DC

390 V DC

External control voltage

Uc

V

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

24 V DC (max. 100 mA)

Reference voltage

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

Switch-on threshold for the braking
transistor
Control section

Note

CA04020001Z-EN-INT

1) With

a switching frequency of 4 kHz and an ambient air temperature of +40°C or +50°C for IP20/NEMA 0

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

62

PowerXL™ variable frequency drives
Mains chokes, motor chokes

Technical data
Mains chokes, motor chokes

DX-LN1…

DX-LN3…

DX-LM3…

IEC/EN 61558-2-20-2000,
VDE 0570 Part 2-20/2001-04,
UL, CSA
-25 to +40, up to 70 with current
derating (see the note)
-25 - +85

IEC/EN 61558-2-20-2000,
VDE 0570 Part 2-20/2001-04,
UL, CSA
-25 to +40, up to 70 with current
derating (see the note)
-25 - +85

IEC/EN 61558-2-20-2000,
VDE 0570 Part 2-20/2001-04,
UL, CSA
-25 to +40, up to 70 with current
derating (see the note)
-25 - +85

11 ms2/15
3 shocks
1 (0 - 150 Hz)

11 ms2/15
3 shocks
1 (0 - 150 Hz)

11 ms2/15
3 shocks
1 (0 - 150 Hz)

0.35 mm at 10 - 55 Hz

0.35 mm at 10 - 55 Hz

0.35 mm at 10 - 55 Hz

0 – 1000 above sea level,
up to 5000 with current reduction
(see notes)
Standing vertically, suspended
horizontally
< 50

0 – 1000 above sea level,
up to 5000 with current reduction
(see notes)
Standing vertically, suspended
horizontally
< 50

0 – 1000 above sea level,
up to 5000 with current reduction
(see notes)
Standing vertically, suspended
horizontally
< 50

General
Standards

Operating temperature

°C

Storage temperature

ϑ

°C

Mechanical shock resistance

g

Vibration resistance

g

Vibration
Altitude

m

Mounting position
Free surrounding areas

MM

Protection type

IP20 (terminal)

IP20 (terminal)

IP20 (terminal)

Rated duty factor

% DF

100

100

100

Weight

kg

0.7

1.5

1.5

Electrical data
Rated operational voltage
Max. supply voltage
Operating frequency

f

Insulation class

1 AC 230 V

3 AC 400 V

3 AC 400 V

V AC

260 V + 0% (50/60 Hz)

550 V + 0% (50/60 Hz)

750 V + 0% (50/60 Hz)

Hz

50/60

50/60

0…200

B

B

B

Connection
Terminations

✓

✓

✓

Connection lugs

-

✓ (≧ 50 A)

✓ (≧ 63 A)

PE stud

✓

✓

✓

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

63

Mains chokes, motor chokes

Part no.

Inductance

Cu factor

L

Maximum
heat
dissipatio
n
Pv

Voltage sag

Connection

Drilling

Tightening
torque

Weight

Ie

Uk

Terminal

Terminal
AWG

Connection
lug
mm2

A

mH

W

kg

%

mm2

mm

Nm

kg

Rated operational voltage 1 AC 230 V
DX-LN1-006
5.8
5.05
DX-LN1-009

8.6

3.41

9

0,09

4

11

0,11

4

4

20 - 10

-

-

0.8

0.7

4

20 - 10

-

-

0.8

DX-LN1-013

13

2.25

12

0,18

0.7

4

4

20 - 10

-

-

0.8

DX-LN1-018

18

1.63

17

1.5

0,27

4

4

20 - 10

-

-

0.8

DX-LN1-024

24

1.22

1.5

20

0,33

4

4

20 - 10

-

-

0.8

DX-LN1-032

32

2

0.92

24

0,00

4

4

20 - 10

-

0

0.8

3

Rated operational voltage 3 AC 400 V
DX-LN3-004
3.9
7.51

17

0,25

4

4

20 - 10

-

-

0.8

1.5

DX-LN3-006

6

4.9

19

0,34

4

4

20 - 10

-

-

0.8

1.5

DX-LN3-010

10

2.94

33

0,45

4

4

20 - 10

-

-

0.8

2.2

DX-LN3-016

16

1.84

44

0,53

4

4

20 - 10

-

-

0.8

2.9

DX-LN3-025

25

1.18

57

0,90

4

4

20 - 10

-

-

0.8

4.8

DX-LN3-040

40

0.64

59

0,91

2.5

10

20 - 6

-

-

1.5

4.8

DX-LN3-050

50

0.37

58

1,08

2.5

-

-

Cu 15 x 2

7

3

5.9

DX-LN3-060

60

0.31

60

1,51

2.5

-

-

Cu 15 x 2

7

3

5.9

DX-LN3-080

80

0.23

86

1,67

2.5

-

-

Cu 20 x 3

9

6

7.3

DX-LN3-100

100

0.18

101

1,68

2.5

-

-

Cu 20 x 3

9

6

10.2

DX-LN3-120

120

0.15

100

2,26

2.5

-

-

Cu 25 x 5

11

10

10.2

DX-LN3-160

160

0.11

140

2,35

2.5

-

-

Cu 25 x 5

11

10

12.3

DX-LN3-200

200

0.09

154

3,81

2.5

-

-

Cu 25 x 5

11

10

14.9

DX-LN3-250

250

0.07

155

4,26

2.5

-

-

Cu 40 x 5

14

15.5

20.6

DX-LN3-300

300

0.06

196

4,28

2.5

-

-

Cu 40 x 5

14

15.5

20.6

DX-LN3-303

303

0.06

230

0,00

2.5

-

-

Cu 40 x 5

14

15.5

20.6

DX-LN3-370

370

0.05

290

0,00

2.5

-

-

Cu 40 x 5

14

15.5

24.3

DX-LN3-450

450

0.04

300

0,00

2.5

-

-

Cu 40 x 10

14

15.5

23.8

Part no.

Rated
operational
current

Inductance

max. heat dissipation
(pulse frequency)

Drilling

Tightening
torque

Weight

DC1, DA1

Rated
operational
current

Mains choke

(3 kHz)

(5 kHz)

(12 kHz)

Cu factor

Connection

Terminal

Terminal

Connection
lug

Ie

L

Pv

Pv

Pv

A

mH

W

W

W

kg

mm2

AWG

mm2

mm

Nm

kg

Rated operational voltage 3 AC 400 V
5
2
DX-LM3-005

12

14

24

0,29

4

20 - 10

-

-

0.8

1.5

DX-LM3-008

8

4.1

32

46

54

1,09

4

20 - 10

-

-

0.8

4.8

DX-LM3-011

11

3

45

66

71

1,23

4

20 - 10

-

-

0.8

4.8

DX-LM3-016

16

1.5

50

75

78

0,88

4

20 - 10

-

-

0.8

4.8

DX-LM3-035

35

1

75

114

116

2,30

4

20 - 10

-

-

0.8

7.3

DX-LM3-050

50

0.6

110

157

168

3,60

10

20 - 6

-

-

1.5

12.3

DX-LM3-063

63

0.5

130

190

193

3,01

-

-

Cu 15 x 2

7

3

14.9

DX-LM3-080

80

0.5

132

206

206

5,88

-

-

Cu 20 x 2

9

6

20.6

DX-LM3-100

100

0.45

177

279

294

10,10

-

-

Cu 20 x 2

9

6

31

DX-LM3-150

150

0.35

293

418

424

8,22

-

-

Cu 25 x 5

11

10

45

DX-LM3-180

180

0.3

418

298

439

14,75

-

-

Cu 25 x 5

11

10

45

DX-LM3-220

220

0.2

344

512

517

11,37

-

-

Cu 40 x 5

14

15.5

45

DX-LM3-260

260

0.15

358

526

520

11,10

-

-

Cu 40 x 5

14

15.5

45

DX-LM3-303

303

0.15

685

-

-

0,00

-

-

Cu 40 x 5

14

15.5

48.7

DX-LM3-370

370

0.12

685

-

-

0,00

-

-

Cu 40 x 5

14

15.5

61.7

DX-LM3-450

450

0.1

730

-

-

0,00

-

-

Cu 40 x 10

14

15.5

81.7

Motor chokes

CA04020001Z-EN-INT

www.eaton.eu

64

PowerXL™ variable frequency drives
DC1

Dimensions
DC1

b2

DC1, sizes FS1 - FS3, degree of protection IP20/NEMA 0
⌀

⌀1

b1
b

⌀2

EMC
VAR
1

2

3

4

5

6

7 8

9 10 11

a1
a

a
mm (inch)
81 (3.19)
107 (4.21)
131 (5.16)

c1
c

a1
mm (inch)
50 (1.97)
75 (2.95)
100 (3.94)

b
mm (inch)
184 (7.24)
231 (9.09)
273 (10.75)

b1
mm (inch)
170 (6.69)
215 (8.46)
255 (10.04)

b2
mm (inch)
7 (0.28)
8 (0.31)
8.5 (0.33)

c
mm (inch)
124 (4.88)
152 (5.98)
175 (6.89)

c1
mm (inch)
4 (0.16)
5 (0.2)
5 (0.2)

⌀1
mm (inch)
6 (0.24)
6 (0.24)
6 (0.24)

⌀2
mm (inch)
12 (0.47)
12 (0.47)
12 (0.47)

Weight
kg
1.1
2.6
4

Size
FS1
FS2
FS3

DC1, sizes FS1 - FS3, degree of protection IP66/NEMA 4X
⌀1

b2

b1

b1
b

⌀2

a1
a1
a

a
mm (inch)
161 (6.34)
188 (7.4)
210.5 (8.29)

a1
mm (inch)
148.5 (5.85)
176 (6.93)
197.5 (7.78)

CA04020001Z-EN-INT

c1
c

b
mm (inch)
232 (9.13)
257 (10.12)
310 (12.2)

www.eaton.eu

b1
mm (inch)
189 (7.44)
200 (7.87)
251.5 (9.9)

b2
mm (inch)
25 (0.98)
28.5 (1.12)
33.4 (1.31)

c
mm (inch)
184 (7.24)
192 (7.56)
234 (9.21)

c1
mm (inch)
3.5 (0.14)
3.5 (0.14)
3.5 (0.14)

⌀1
mm (inch)
4 (0.15)
4.2 (0.16)
4.2 (0.16)

⌀2
mm (inch)
8 (0.31)
8.5 (0.33)
8.5 (0.33)

Weight
kg (lbs)
2.5 (5.51)
4.7 (10.36)
7.9 (17.42)

Size
FS1
FS2
FS3

PowerXL™ variable frequency drives

65

DC1, DA1
DC1, DA1

DC1, DA1

DC1, sizes FS1 - FS3, degree of protection IP66/NEMA 4X, with local controls
⌀1

0
REV

⌀2

FWD

OFF

PWR

b2

b1

b1
b

ON

a1
c1

a1
a

a
mm (inch)
161 (6.34)
188 (7.4)
210.5 (8.29)

a1
mm (inch)
148.5 (5.85)
176 (6.93)
197.5 (7.78)

c

b
mm (inch)
232 (9.13)
257 (10.12)
310 (12.2)

b1
mm (inch)
189 (7.44)
200 (7.87)
251.5 (9.9)

b2
mm (inch)
25 (0.98)
28.5 (1.12)
33.4 (1.31)

c
mm (inch)
184 (7.24)
192 (7.56)
234 (9.21)

c1
mm (inch)
3.5 (0.14)
3.5 (0.14)
3.5 (0.14)

⌀1
mm (inch)
4 (0.15)
4.2 (0.16)
4.2 (0.16)

⌀2
mm (inch)
8 (0.31)
8.5 (0.33)
8.5 (0.33)

Weight
kg (lbs)
2.8 (6.17)
5 (11.02)
8.2 (18.08)

Size
FS1
FS2
FS3

b2

DA1, sizes FS2 - FS3, degree of protection IP20/NEMA 0
⌀

⌀1
DC-

L1/L

L2/N

L3

⌀2

EMC

b1
b

VAR

1

2

3

4

5

6

7

8 9 10 11 12 13

COM
14 15 16 17 18

DC+

BR

U

V

W

a1
a

a
mm (inch)
107 (4.21)
131 (5.16)

a1
mm (inch)
75 (2.95)
100 (3.94)

c1
c

b
mm (inch)
231 (9.09)
273 (10.75)

b1
mm (inch)
215 (8.46)
255 (10.04)

b2
mm (inch)
8 (0.31)
8.5 (0.33)

c
mm (inch)
186 (7.32)
204 (8.03)

c1
mm (inch)
5 (0.2)
5 (0.2)

⌀1
mm (inch)
6 (0.24)
6 (0.24)

⌀2
mm (inch)
12 (0.47)
12 (0.47)

Weight
kg
1.8
3.5

Size
FS2
FS3

CA04020001Z-EN-INT

www.eaton.eu

66

PowerXL™ variable frequency drives
DA1

DA1

DA1, sizes FS2 - FS3, degree of protection IP66/NEMA 4X
⌀1

b2

b1

b1
b

⌀2

a1
c

a1
a

a
mm (inch)
188 (7.4)
211 (8.29)

a1
mm (inch)
176 (6.93)
198 (7.78)

b
mm (inch)
257 (10.12)
310 (12.2)

b1
mm (inch)
200 (7.87)
252 (9.9)

b2
mm (inch)
20 (0.79)
25 (0.98)

c
mm (inch)
239.3 (9.42)
266.3 (10.48)

⌀1
mm (inch)
4.2 (0.16)
4.2 (0.16)

⌀2
mm (inch)
8.5 (0.33)
8.5 (0.33)

Weight
kg (lbs)
4.5 (10.4)
7 (15.9)

Size
FS2
FS3

DA1, sizes FS2 - FS3, degree of protection IP66/NEMA 4X, with local controls
⌀1

⌀2

0
REV

PWR

FWD

OFF

b2

b1

b1
b

ON

a1
c

a1
a

a
mm (inch)
188 (7.4)
211 (8.29)

a1
mm (inch)
176 (6.93)
198 (7.78)

CA04020001Z-EN-INT

b
mm (inch)
257 (10.12)
310 (12.2)

www.eaton.eu

b1
mm (inch)
200 (7.87)
252 (9.9)

b2
mm (inch)
20 (0.79)
25 (0.98)

c
mm (inch)
239.3 (9.42)
266.3 (10.48)

⌀1
mm (inch)
4.2 (0.16)
4.2 (0.16)

⌀2
mm (inch)
8.5 (0.33)
8.5 (0.33)

Weight
kg (lbs)
4.8 (10.6)
7.3 (16.1)

Size
FS2
FS3

PowerXL™ variable frequency drives

67

DA1

⌀

DC1, DA1

b2

DA1, sizes FS4 - FS7, degree of protection IP55

⌀1

b1
b

⌀2

a1
a

a
mm (inch)
171 (6.73)
235 (9.25)
330 (12.99)
330 (12.99)

a1
mm (inch)
110 (4.33)
175 (6.89)
200 (7.87)
200 (7.87)

c1
c

b
mm (inch)
450 (17.72)
540 (20.28)
865 (34.06)
1280 (50.39)

b1
mm (inch)
428 (16.85)
515 (20.28)
840 (33.07)
1255 (44.41)

b2
mm (inch)
9 (0.35)
12 (0.47)
15 (0.59)
15 (0.59)

c
mm (inch)
240 (9.45)
270 (10.63)
330 (12.99)
360 (14.17)

c1
mm (inch)
2 (0.08)
2 (0.08)
2 (0.08)
2 (0.08)

⌀1
mm (inch)
8 (0.31)
8 (0.31)
11 (0.43)
11 (0.43)

⌀2
mm (inch)
15 (0.59)
15 (0.59)
22 (0.87)
22 (0.87)

Weight
kg
11.5
22.5
50
80

b2
mm (inch)
33 (1.3)

c
mm (inch)
516 (20.31)

c1
mm (inch)
2 (0.08)

⌀1
mm (inch)
18 (0.71)

⌀2
mm (inch)
35 (1.38)

Weight
kg
270

Size
FS4
FS5
FS6
FS7

DA1, size FS8, degree of protection IP40
Control panel version
a
mm (inch)
500 (19.69)

a1
mm (inch)
350 (13.78)

b
mm (inch)
2000 (78.74)

b1
mm (inch)
1950 (76.77)

Size
FS8

CA04020001Z-EN-INT

www.eaton.eu

68

PowerXL™ variable frequency drives
Accessories

Accessories

Expansion modules for DC1

56 mm (2.2")

39 mm (1.54")
41 mm (1.61")

56 mm (2.2")

39 mm (1.54")
41 mm (1.61")

18 mm (0.71")

DXC-EXT-2RO

12.3 mm
(0.48")

DXC-EXT-LOCSIM

27 mm (1.06")
36 mm (1.42")

56 mm (2.2")

Expansion modules for DA1

21 mm (0.83")
23 mm (0.91")

DXA-EXT-3DI1RO
DXA-EXT-3RO
DXA-EXT-ENCOD

41 mm (1.61")
48 mm (1.89")

33.7 mm (1.33")
60 mm (2.36")
70 mm (2.75")

Fieldbus module for DA1

OP

ST

PROFIBUS DP-V1
41 mm (1.61")
48 mm (1.89")

CA04020001Z-EN-INT

www.eaton.eu

22.3 mm (0.88")

DX-NET-PROFIBUS

33.7 mm (1.33")
51.8 mm (2.04")

24 mm (0.95")

18 mm (0.71")

DXC-EXT-IO110
DXC-EXT-IO230
DXC-EXT-2RO1AO

PowerXL™ variable frequency drives

69

Accessories

External keypad
DC1, DA1

DX-KEY-OLED

110 mm (4.33")

81 mm (3.19")

DX-KEY-LED

Hand

66 mm (2.6")
26 mm
(1.02")

Auto

4 mm
(0.16")

90 mm (3.54")
23.5 mm
(0.93")

4.5 mm
(0.18")

Cable and splitter

19 mm
(0.75")

DX-SPL-RJ45-2SL1PL

42 mm (1.65")

145 mm (5.7")

Interface converter
DX-COM-PCKIT
USB
6 5 4 3 2 1
RxD
TxD

SW

77 mm (3.03")

PWR

Serial

81 mm (3.19")

23 mm
(0.91")

CA04020001Z-EN-INT

www.eaton.eu

70

PowerXL™ variable frequency drives
Mains chokes, motor chokes

Mains chokes, motor chokes

Mains chokes
DX-LN1-…
1 2

c1 ± 5 mm
(c1 ± 0.20”)

c ± 5 mm
(c ± 0.20”)

PE

od

a1

b1
b2

a

b ± 5 mm
(b ± 0.20”)

DX-LN1-006
DX-LN1-009
DX-LN1-013
DX-LN1-018
DX-LN1-024
DX-LN1-032

a
mm (inch)
66 (2.6)
66 (2.6)
84 (3.31)
84 (3.31)
84 (3.31)
105 (4.13)

a1
mm (inch)
50 (1.97)
50 (1.97)
64 (2.52)
64 (2.52)
64 (2.52)
84 (3.31)

b
mm (inch)
71 (2.8)
71 (2.8)
67 (2.64)
67 (2.64)
81 (3.19)
102 (4.02)

b1
mm (inch)
44 (1.73)
44 (1.73)
47 (1.85)
47 (1.85)
61 (2.4)
65 (2.56)

b2
mm (inch)
55 (2.17)
55 (2.17)
60 (2.36)
60 (2.36)
74 (2.91)
81 (3.19)

c
mm (inch)
80 (3.15)
80 (3.15)
90 (3.54)
90 (3.54)
90 (3.54)
121 (4.76)

c1
mm (inch)
61 (2.36)
61 (2.36)
75 (2.95)
75 (2.95)
75 (2.95)
94 (3.7)

d
mm (inch)
4.5 x 8 (0.18 x 0.31)
4.5 x 8 (0.18 x 0.31)
4.8 x 8 (0.18 x 0.31)
4.8 x 8 (0.18 x 0.31)
4.8 x 8 (0.18 x 0.31)
5.8 x 11 (0.23 x 0.43)

Weight
kg
0.7
0.7
1.5
1.5
2
3

Mains chokes, motor chokes
DX-LN3-004…-DX-LN3-040
DX-LM3-005…-DX-LM3-050
U1 U2 V1 V2 W1W2

c1 ± 5 mm
(c1 ± 0.20”)

PE

c ± 5 mm
(c ± 0.20”)

PE

od

a1

b1

a

b2
b ± 5 mm (b ± 0.20”)

DX-LN3-004
DX-LN3-006
DX-LN3-010
DX-LN3-016
DX-LN3-025
DX-LN3-040
DX-LM3-005
DX-LM3-008
DX-LM3-011
DX-LM3-016
DX-LM3-035
DX-LM3-050

a
mm (inch)
115 (4.53)
115 (4.53)
140 (5.51)
140 (5.51)
195 (7.68)
195 (7.68)
115 (4.53)
195 (7.68)
195 (7.68)
195 (7.68)
220 (8.66)
270 (10.63)

CA04020001Z-EN-INT

a1
mm (inch)
100 (3.94)
100 (3.94)
125 (4.92)
125 (4.92)
175 (6.89)
175 (6.89)
100 (3.94)
175 (6.89)
175 (6.89)
175 (6.89)
200 (7.87)
250 (9.84)

www.eaton.eu

b
mm (inch)
66 (2.6)
66 (2.6)
61 (2.4)
71 (2.8)
104 (4.09)
104 (4.09)
66 (2.6)
104 (4.09)
104 (4.09)
104 (4.09)
132 (5.2)
106 (4.17)

b1
mm (inch)
50 (1.97)
50 (1.97)
50 (1.97)
50 (1.97)
50 (1.97)
50 (1.97)
50 (1.97)
50 (1.97)
50 (1.97)
50 (1.97)
75 (2.95)
75 (2.95)

b2
mm (inch)
66 (2.6)
66 (2.6)
61 (2.4)
71 (2.8)
76.5 (3.01)
76.5 (3.01)
66 (2.6)
76.5 (3.01)
76.5 (3.01)
76.5 (3.01)
101.5 (4)
96 (3.78)

c
mm (inch)
118 (4.65)
118 (4.65)
138 (5.43)
138 (5.43)
175 (6.89)
188 (7.4)
118 (4.65)
175 (6.89)
175 (6.89)
175 (6.89)
195 (7.68)
228 (8.98)

c1
mm (inch)
84 (3.31)
84 (3.31)
105 (4.13)
105 (4.13)
134 (5.28)
134 (5.28)
84 (3.31)
134 (5.28)
134 (5.28)
134 (5.28)
160 (6.3)
198 (7.8)

d
mm (inch)
5 x 10 (0.2 x 0.39)
5 x 10 (0.2 x 0.39)
5 x 10 (0.2 x 0.39)
5 x 10 (0.2 x 0.39)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)
5 x 10 (0.2 x 0.39)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)

Weight
kg
1.5
1.5
2.2
2.9
4.8
4.8
1.5
4.8
4.8
4.8
7.3
12.3

PowerXL™ variable frequency drives

71

Mains chokes, motor chokes
Mains chokes, motor chokes

Mains chokes, motor chokes

PE

U1

V1

W1

U2

V2

W2

U2

V2

W2

c ± 5 mm
(c ± 0.20”)

PE

DC1, DA1

DX-LN3-050…-DX-LN3-450
DX-LM3-063…-DX-LM3-450

a1

⌀d

b1

a

b2
b ± 10 mm (b ± 0.39”)

Height tolerance depends on gap
The position of connection lugs U2-V2-W2 depends on the coil material and can deviate from the position illustrated here.

DX-LN3-050
DX-LN3-060
DX-LN3-080
DX-LN3-100
DX-LN3-120
DX-LN3-160
DX-LN3-200
DX-LN3-250
DX-LN3-300
DX-LN3-303
DX-LN3-370
DX-LN3-450
DX-LM3-063
DX-LM3-080
DX-LM3-100
DX-LM3-150
DX-LM3-180
DX-LM3-220
DX-LM3-260
DX-LM3-303
DX-LM3-370
DX-LM3-450

a
mm (inch)
195 (7.68)
195 (7.68)
220 (8.66)
220 (8.66)
220 (8.66)
270 (10.63)
270 (10.63)
270 (10.63)
270 (10.63)
270 (10.63)
384 (15.12)
384 (15.12)
270 (10.63)
270 (10.63)
384 (15.12)
384 (15.12)
384 (15.12)
384 (15.12)
384 (15.12)
454 (17.87)
454 (17.87)
454 (17.87)

a1
mm (inch)
175 (6.89)
175 (6.89)
200 (7.87)
200 (7.87)
200 (7.87)
250 (9.84)
250 (9.84)
250 (9.84)
250 (9.84)
250 (9.84)
350 (13.78)
350 (13.78)
250 (9.84)
250 (9.84)
350 (13.78)
350 (13.78)
350 (13.78)
350 (13.78)
350 (13.78)
425 (16.73)
425 (16.73)
425 (16.73)

b
mm (inch)
105 (4.13)
105 (4.13)
110 (4.33)
130 (5.12)
130 (5.12)
125 (4.92)
155 (6.1)
155 (6.1)
155 (6.1)
155 (6.1)
215 (8.46)
215 (8.46)
155 (6.1)
155 (6.1)
215 (8.46)
260 (10.24)
260 (10.24)
260 (10.24)
260 (10.24)
270 (10.63)
285 (11.22)
300 (11.81)

b1
mm (inch)
75 (2.95)
75 (2.95)
50 (1.97)
75 (2.95)
75 (2.95)
75 (2.95)
100 (3.94)
100 (3.94)
100 (3.94)
100 (3.94)
100 (3.94)
100 (3.94)
100 (3.94)
100 (3.94)
100 (3.94)
150 (5.91)
150 (5.91)
150 (5.91)
150 (5.91)
100 (3.94)
125 (4.92)
150 (5.9)

b2
mm (inch)
91.5 (3.6)
91.5 (3.6)
81.5 (3.21)
101.5 (4)
101.5 (4)
96 (3.75)
120 (4.72)
125 (4.92)
125 (4.92)
125 (4.92)
130 (5.12)
130 (5.12)
120 (4.72)
125 (4.92)
130 (5.12)
180 (7.09)
180 (7.09)
180 (7.09)
180 (7.09)
150 (5.9)
165 (6.5)
180 (7.09)

c
mm (inch)
132 ±5 (5.2 ±0.2)
132 ±5 (5.2 ±0.2)
160 ±5 (6.3 ±0.2)
160 ±5 (6.3 ±0.2)
160 ±5 (6.3 ±0.2 )
200 ±5 (7.87 ±0.2)
202 ±5 (7.95 ±0.2)
210 ±5 (8.27 ±0.2)
210 ±5 (8.27 ±0.2)
210 ±5 (8.27 ±0.2)
258 ±5 (10.16 ±0.2)
258 ±5 (10.16 ±0.2)
202 ±10 (7.95 ±0.39)
210 ±10 (8.27 ±0.39)
258 ±30 (10.16 ±1.18)
258 ±30 (10.16 ±1.18)
258 ±30 (10.16 ±1.18)
258 ±30 (10.16 ±1.18)
258 ±30 (10.16 ±1.18)
313 ±5 (12.32 ±0.2)
313 ±5 (12.32 ±0.2)
313 ±5 (12.32 ±0.2)

d
mm (inch)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)
8 x 13 (0.31 x 0.51)
10 x 18 (0.39 x 0.71)
10 x 18 (0.39 x 0.71)
10 x 18 (0.39 x 0.71)
12 x 20 (0.47 x 0.79)
12 x 20 (0.47 x 0.79)
8 x 13 (0.31 x 0.51)
10 x 18 (0.39 x 0.71)
12 x 20 (0.47 x 0.79)
12 x 20 (0.47 x 0.79)
12 x 20 (0.47 x 0.79)
12 x 20 (0.47 x 0.79)
12 x 20 (0.47 x 0.79)
12 x 20 (0.47 x 0.79)
12 x 20 (0.47 x 0.79)
12 x 20 (0.47 x 0.79)

CA04020001Z-EN-INT

Weight
kg
5.9
5.9
7.3
10.2
10.2
12.3
14.9
20.6
20.6
20.6
24.3
23.8
14.9
20.6
31
45
45
45
45
48.7
61.7
81.7

www.eaton.eu

72

PowerXL™ variable frequency drives
Sine filter

Sine filter

Sine filter
DX-SIN3-004 - DX-SIN3-180

⌀ d2


c



a1
a

DX-SIN3-004
DX-SIN3-010
DX-SIN3-016
DX-SIN3-023
DX-SIN3-032
DX-SIN3-037
DX-SIN3-048
DX-SIN3-061
DX-SIN3-072
DX-SIN3-090
DX-SIN3-115
DX-SIN3-150
DX-SIN3-180

a
mm (inch)
155 (6.1)
155 (6.1)
190 (7.48)
240 (9.45)
240 (9.45)
240 (9.45)
240 (9.45)
300 (11.81)
300 (11.81)
300 (11.81)
360 (14.17)
360 (14.17)
360 (14.17)

CA04020001Z-EN-INT

b1

⌀ d1
b

a1
mm (inch)
130 (5.12)
130 (5.12)
170 (6.69)
190 (7.48)
190 (7.48)
190 (7.48)
190 (7.48)
240 (9.45)
240 (9.45)
240 (9.45)
264 (10.39)
264 (10.39)
264 (10.39)

www.eaton.eu

b
mm (inch)
105 (4.13)
120 (4.72)
160 (6.3)
190 (7.48)
200 (7.87)
210 (8.27)
220 (8.66)
228 (8.97)
240 (9.45)
270 (10.63)
210 (8.27)
225 (8.86)
240 (9.45)

b1
mm (inch)
56 (2.2)
71 (2.8)
67 (2.64)
105 (4.13)
105 (4.13)
115 (4.53)
125 (4.92)
133 (5.24)
145 (5.71)
171 (6.73)
125 (4.92)
140 (5.51)
154 (6.06)

c
mm (inch)
160 (6.3)
160 (6.3)
185 (7.28)
280 (11.02)
280 (11.02)
280 (11.02)
280 (11.02)
315 (12.4)
315 (12.4)
320 (12.6)
415 (16.34)
415 (16.34)
415 (16.34)

d1

d2

4 x M5
4 x M5
4 x M5
4 x M6
4 x M6
4 x M6
4 x M6
4 x M8
4 x M8
4 x M8
4 x M8
4 x M10
4 x M10

M4
M4
M4
M6
M6
M6
M6
M8
M8
M8
M8
M8
M8

Weight
kg
4.2
6.1
9.4
14.5
19.7
21.3
26.2
35
39
53.3
66
69
88.7

PowerXL™ variable frequency drives

73

Sine filter
Sine filter

Sine filter

≦ 450 mm (≦ 17.7") ± 3 mm (0.1")

DC1, DA1

DX-SIN3-250

≦ 320 mm (≦ 12.6")
≦ 400 mm (≦ 15.7")

≦ 450 mm (≦ 17.7")
≦ 500 mm (≦ 19.7")

⌀ 4 x M10
PE = M12

⌀ 6 x M10
PE = M12

32.5 mm
(1.3")

180 mm (7.1")

185 mm (7.3")
610 mm (24")

450 mm (17.7") ± 3 mm (0.1")

DX-SIN3-440

180 mm (7.1")

480 mm (18.9")
540 mm (21.3")

DX-SIN3-480

408 mm (16.1") ± 3 mm (0.1")

425 mm (16.7") ± 3 mm (0.1")

PE = M12

110 mm
(4.3")

125 mm
(4.9")

165 mm (6.5")
160 mm (6.3")
≦ 730 mm (≦ 28.7")

d1 13 x 26 mm (0.5 x 1")
8 x M10

≦ 370 mm (≦ 14.6")

CA04020001Z-EN-INT

www.eaton.eu

74

PowerXL™ variable frequency drives
Braking resistances DX-BR...

Braking resistances DX-BR...

41 mm (1.61")

DX-BR3-100

9 mm
(0.35")

188 mm (7.4")

70 mm (2.76")

80 mm (3.15")

DX-BR5-033

⌀ 5.3 mm
(⌀ 0.21")

10 mm
(0.39")

310 mm (12.2")
330 mm (12.99")

DX-BR… with connection cable
a
a1

b1
b

c

1m
(3.28 ft)

6 x 12

DX-BR200-0K4
DX-BR400-0K4
DX-BR150-0K5
DX-BR100-0K8
DX-BR200-0K8
DX-BR075-1K4
DX-BR100-1K4
DX-BR150-1K4
DX-BR100-1K6

a
mm (inch)
95 (3.07)

a1
mm (inch)
70 (2.76)

b
mm (inch)
445 (17.52)

b1
mm (inch)
425 (16.73)

c
mm (inch)
95 (3.07)

Weight
kg (lbs)
2.4 (5.29)

140 (5.51)
140 (5.51)

120 (4.72)
120 (4.72)

395 (15.55)
445 (17.52)

375 (14.76)
425 (16.73)

120 (4.72)
120 (4.72)

3.7 (8.16)
4 (8.82)

230 (9.06)

210 (8.27)

445 (17.52)

425 (16.73)

120 (4.72)

5.7 (12.57)

2 x 140 (5.51)

2 x120 (4.72)

445 (17.52)

425 (16.73)

120 (4.72)

2 x 4 (8.82)

CA04020001Z-EN-INT

www.eaton.eu

PowerXL™ variable frequency drives

75

Braking resistances DX-BR...

b1
b

DC1, DA1

DX-BR… with connection cable

a1
a

6 x 12

c

a

a1

b

b1

c

Weight

mm (inch)

mm (inch)

mm (inch)

mm (inch)

mm (inch)

kg (lbs)

DX-BR050-0K4
DX-BR100-0K4
DX-BR100-0K2

95 (3.07)

70 (2.76)

445 (17.52)

425 (16.73)

95 (3.07)

2.1 (4.63)

95 (3.07)

70 (2.76)

345 (13.58)

325 (12.8)

95 (3.07)

1.7 (3.75)

DX-BR050-0K8

140 (5.51)

120 (4.72)

445 (17.52)

425 (16.73)

120 (4.72)

4 (8.82)

DX-BR035-1K1

230 (9.06)

210 (8.27)

445 (17.52)

425 (16.73)

120 (4.72)

5.5 (12.13)

DX-BR… with connection cable

b1
b

⌀

c

a1
a

DX-BR022-1K4
DX-BR012-3K1
DX-BR022-3K1
DX-BR040-3K1
DX-BR047-3K1
DX-BR050-3K1
DX-BR006-5K1
DX-BR012-5K1
DX-BR022-5K1
DX-BR040-5K1
DX-BR047-5K1
DX-BR050-5K1
DX-BR075-5K1
DX-BR100-6K2
DX-BR006-9K2
DX-BR012-9K2
DX-BR022-9K2
DX-BR047-9K2

a
mm (inch)
226 (8.9)
326 (12.83)

a1
mm (inch)
200 (7.87)
300 (11.81)

b
mm (inch)
485 (19.09)
485 (19.09)

b1
mm (inch)
380 (14.96)
380 (14.96)

c
mm (inch)
301 (11.85)
301 (11.85)

Ø1
mm (inch)
9 (0.35)
9 (0.35)

Weight
kg (lbs)
8.6 (18.96)
12 (26.46)

426 (16.77)

400 (15.75)

485 (19.09)

380 (14.96)

301 (11.85)

9 (0.35)

15.5 (34.17)

526 (20.71)
626 (24.65)

500 (19.69)
600 (23.62)

485 (19.09)
485 (19.09)

380 (14.96)
380 (14.96)

301 (11.85)
301 (11.85)

9 (0.35)
9 (0.35)

18 (39.68)
20.5 (45.19)

CA04020001Z-EN-INT

www.eaton.eu

76

PowerXL™ variable frequency drives
Braking resistances DX-BR...

380 mm (14.96")
485 mm (19.09")

DX-BR002-54K3, DX-BR006-18K1, DX-BR012-18K1

600 mm (23.62")
626 mm (24.65")

⌀ 9 mm
(⌀ 0.35")

40 kg
(88.18 lbs)

601 mm (23.66")

380 mm (14.96")
485 mm (19.09")

DX-BR002-102K4, DX-BR006-33K3

700 mm (27.56")
736 mm (28.98")

CA04020001Z-EN-INT

www.eaton.eu

⌀ 9 mm
(⌀ 0.35")

85 kg
(185.19 lbs)

1020 mm (40.16")

PowerXL™ variable frequency drives

77

Notes

DC1, DA1

Notes

CA04020001Z-EN-INT

www.eaton.eu

9000X SVX, SPX variable frequency drive
9000X variable frequency drives are ideal for sophisticated applications. With two
different device series, they make a compelling case in a variety of scenarios: SVX standard variable frequency drives when it comes to simple and complex motor control
systems in industrial machine building environments, and SPX application frequency
drives when it comes to sophisticated, high-performance requirements. In both openloop and closed-loop modes, their vector control guarantees reliable, dynamic, and
sophisticated motor control performance when working with three-phase induction or
permanent magnet motors.
SVX variable frequency drive
Variable frequency drives for operation with two overload options: 150% or 110%. The compact enclosures are rated IP21 (NEMA 1) and IP54 (NEMA 12) and come with an integrated
radio interference suppression filter. A braking chopper is integrated into all units up to size
FR6, and, in addition, there are two different models.
SVX…-4A…: UIN 3~400 V/UOUT 3~400 V, allocated motor outputs 0.75 – 132 kW
SVX…-5A…: UIN 3~690 V/UOUT 3~690 V, allocated motor outputs 2.2 – 160 kW
SPX variable frequency drive
Variable frequency drives for operation with two overload options: 150% or 110%. The enclosures for the compact devices are rated IP21 (NEMA 1) and IP54 (NEMA 12) and come with an
integrated radio interference suppression filter. A braking chopper is integrated into all units up
to size FR6, and, in addition, there are two different models.
SPX…-4A…: UIN 3~400 V/UOUT 3~400 V, allocated motor outputs 0.75 – 132 kW1)
SPX…-5A…: UIN 3~690 V/UOUT 3~690 V, allocated motor outputs 2.2 – 160 kW1)
1) Higher outputs of up to 1,100 kW (400 V) and 2,000 kW (690 V) are covered by variable frequency drives with
sizes FR10 to FR14. These devices are available upon request from your sales office.

Variable frequency drive 9000X

79

Description
variable frequency drives SVX, SPX

80

Technical overview
variable frequency drives SVX, SPX

81

Key to type references
82

Ordering
variable frequency drives SVX

83

variable frequency drives SPX

88

Accessories

92

Technical data
variable frequency drives SVX, SPX

94

Dimensions
variable frequency drives SVX, SPX

CA04020001Z-EN-INT

102

www.eaton.eu

SVX, SPX

variable frequency drives SVX, SPX

80

Variable frequency drive 9000X
SVX, SPX

Description
SVX, SPX

Brake Resistor

Power
Module

Brake
Chopper

IGBT
Inverter

Rectifier

AC Choke

Utility

3~

L1

Input

L2
L3

EMC

Current
Sensors

Motor
U Output
V
W EMC

3~

Charg Res

Fan
Power
Supply

Measurements

PE
Gate
Drivers

Voltage
Sensors

Control
Keypad

RS232

Motor
Control
ASIC

Motor and
App lication
Control

Control
Module

Control
I/O

Control
I/O

Control
I/O

Control
I/O

Control
I/O

SVX variable frequency drive

SPX variable frequency drive

SVX units are heavy-duty, all-purpose standard variable frequency drives.
Featuring a variety of application settings, they can be configured to meet
virtually any challenge that arises when used to control induction motors,
including applications involving multiple motors or multiple pumps run in
parallel. SVX variable frequency drives are suitable for all standard
applications in machines, buildings, and industrial projects. One of the factors
contributing to this is their sturdy design, which features integrated chokes
and EMC filters and provides effective protection against interference from
the grid. In addition, their sophisticated motor control design and effective
protection features for both motor and variable frequency drive guarantee
reliable operation.

SPX variable frequency drives are the perfect choice when it comes to
demanding applications in which reliability, a highly dynamic response,
precision, and power are a must. Popular applications include lifting
equipment and conveyances (cranes, winches, elevators, lifts), compressors
and oil pumps, chippers, crushers, mixers, extruders, take-up and pay-off
units, and tunnel boring machines. Multi-purpose SPX variable frequency
drives are designed to cover a wide variety of applications while keeping
things simple. In fact, with their excellent flexibility, they make it easy to adapt
to additional process requirements for custom and complex applications used
to control induction and permanent magnet motors. On top of this, their sturdy
design, which features integrated chokes and EMC filters, provides effective
protection against interference from the grid. Finally, their sophisticated motor
control design and effective protection features for both motor and variable
frequency drive guarantee reliable operation.

Essential features

Essential features

• Performance range:
– 0.75 - 132 kW (UIN: 3~ 400 V / UOUT: 3~ 400 V)
– 2.2 - 160 kW (UIN: 3~ 690 V / UOUT: 3~ 690 V)
• High load capacity:
– H = 2x rated operational current (2 seconds/20 seconds) and 150%
overload (60 seconds/600 seconds)
– L = 2x rated operational current (2 seconds/20 seconds) and 110%
overload (60 seconds/600 seconds)
• Ambient air temperature: -10 °C up to +50 °C without derating
• Degree of protection with compact design: IP21 (NEMA1) and IP54
(NEMA12)
• I/O expansion with plug-in modules (5 slots)
• Optional fieldbus connection (CANopen, PROFIBUS-DP, DeviceNet),
LonWorks
• PID control and power factor correction (PFC) for 1 to 5 pumps
• Programmable start and application wizard for an easy parameter
configuration process
• Multiple display (multi-monitoring) for monitoring up to 3 different readings
at the same time
• V/Hz control with boost and slip compensation
• Dynamic open-loop and closed-loop vector control
• Internal braking chopper available in sizes of up to FR9 (compact design)

• Performance range:
– 0.75 - 132 kW (UIN: 3~ 400 V / UOUT: 3~ 400 V)
– 2.2 - 160 kW (UIN: 3~ 690 V / UOUT: 3~ 690 V)
• Expanded performance range with distributed design (IP00). Please enquire:
– up to 1100 kW (UIN: 3~ 400 V / UOUT: 3~ 400 V)
– up to 2000 kW (UIN: 3~ 690 V / UOUT: 3~ 690 V)
• High load capacity:
– H = 2x rated operational current (2 seconds/20 seconds) and 150%
overload (60 seconds/600 seconds)
– L = 2x rated operational current (2 seconds/20 seconds) and 110%
overload (60 seconds/600 seconds)
• Ambient air temperature: -10 °C up to +50 °C without derating
• Degree of protection with compact design: Up to 132/160 kW: IP21 (NEMA1)
and IP54 (NEMA12)
• I/O expansion with plug-in modules (5 slots)
• Optional fieldbus connection (CANopen, PROFIBUS-DP, DeviceNet),
LonWorks
• PID control and power factor correction (PFC)
• Direct and parallel circuit solutions, even for PM motors with high outputs
• Programmable start and application wizard for an easy parameter
configuration process
• Multiple display (multi-monitoring) for monitoring up to 3 different readings
at the same time
• V/Hz control with boost and slip compensation
• Dynamic open-loop and closed-loop vector control
• Internal braking chopper available in sizes up to FR9

SVX, SPX

CA04020001Z-EN-INT

www.eaton.eu

Variable frequency drive 9000X

81

SVX, SPX

Technical overview
SVX

SPX

400 V AC, 3-phase

✓

✓

690 V AC, 3-phase

✓

✓

380 (-15%) - 500 (+10%)

✓

✓

525 (-15%) - 690 (±10%)

✓

✓

Rated operational voltage

Ue

Mains voltage (50/60Hz)

ULN

Supply frequency

V

fLN

Hz

50/60

50/60

At 110% overload

Ie

A

3.3 - 300

3.3 - 300 (2250)2)

At 150% overload

Ie

A

2.2 - 245

2.2 - 245 (1940)2)

With 400 V, 50 Hz (110% overload)

P

kW

1.1 - 160

1.1 - 160 (1200)2)

With 400 V, 50 Hz (150% overload)

P

kW

0.75 - 132

0.75 - 132 (1100)2)

With 690 V, 60 Hz (110% overload)

P

kW

3 - 200

3 - 200 (2000)2)

With 690 V, 60 Hz (150% overload)

P

kW

2.2 - 160

2.2 - 160 (1800)2)

SVX, SPX

Rated operational current1)

Assigned motor rating 1)

Ambient temperature
Operation

ϑ

°C

-10 - +40

-10 - +40

Storage

ϑ

°C

-40 - +70

-40 - +70

Operation Mode
U/f control

-

✓

sensorless vector control (SLV)

✓

✓

Vector control with feedback (CLV)

✓

✓

1 - 16

1 - 16

400 V AC, 3-phase

✓

✓

690 V AC, 3-phase

✓

✓

0 - 320 Hz

0 - 320 Hz

IP00

-

(✓)2)

IP21

✓

✓

IP54

✓

✓

Radio interference suppression filter

✓

✓

Brake chopper

✓

✓

Analog inputs

parameterizable, 2 x (0 - 10 V, 0/4 - 20 mA)

parameterizable, 2 x (0 - 10 V, 0/4 - 20 mA)

Analog outputs

parameterizable, 1 x (0/4 - 20 mA)

parameterizable, 1 x (0/4 - 20 mA)

Digital inputs

parameterizable, 6 x (max. 30 V DC)

parameterizable, 6 x (max. 30 V DC)

Digital outputs

parameterizable, 1 x (48 V DC / 50mA)

parameterizable, 1 x (48 V DC / 50mA)

Relay outputs

Parameterizable, two N/Os, 8 A (24 VDC) /
8 A (250 VAC) / 0.4 A (125 VDC)
RoHS, ISO 9001

Parameterizable, two N/Os, 8 A (24 VDC) /
8 A (250 VAC) / 0.4 A (125 VDC)
RoHS, ISO 9001

EMC: EN 61800-3:2004+A1-2012

EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
✓

EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
✓

Safety: EN 61800-5-1: 2003

✓

✓

CE, cUL, c-Tick

CE, cUL, c-Tick

Switching frequency

fPWM

Output voltage with Ve

U2

Output Frequency

f2

kHz

Hz

Protection type

Fitted with

Production quality
Standards

Certifications
Notes

1)
2)

L = 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
Higher outputs are covered by variable frequency drives with sizes FR10 to FR14. These devices are available as modules with
protection class IP 00 upon request from your sales office.

CA04020001Z-EN-INT

www.eaton.eu

82

Variable frequency drive 9000X
SVX, SPX

Key to type references
SVX, SPX

SVX 007 A 1 - 4 A 1 B 1
Device series

Type

SVX = Standard frequency drive
SPX = Performance frequency drive

1 = Standard basic device

Assigned motor rating according to
mains voltage category 4, 5
F07 = 0.75 HP = 0.55 kW
001 = 1 HP = 0.75 kW
...
007 = 7.5 HP = 5.5 kW
...
H20 = 2000 HP = 1800 kW
AFD software series

Radio interference suppression filters
1 = C2 class in 1st and 2nd environments
2 = no internal RFI filter
4 = C3 class in 2nd environment
Display

A = Standard version

A = alpha numeric

Degree of protection

Mains voltage category

0 = IP00/open chassis
1 = IP21/NEMA 1
2 = IP54/NEMA 12

4 = 380 (-15 %) - 500 (+10 %)
5 = 525 (-15 %) - 690 (+10 %)

UL/CSA
Information relevant for export to North America

Product Standards
UL File No.
UL Category Control No.
CSA File No.
CSA Class No.
North America Certification
Specially designed for North
America
Suitable for
Max. Voltage Rating
SVX/SPX…-4…
SVX/SPX…-5…
Degree of Protection
SPX…A0…
SVX/SPX…A1…
SVX/SPX…A2…

CA04020001Z-EN-INT

Brake Chopper
N = no internal brake chopper
B = internal brake chopper

UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking
E134360
NMMS, NMMS2, NMMS7. NMMS8
UL report applies to both US and Canada
3211-06
UL listed, certified by UL for use in Canada
No
Branch circuits
3~ 480 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey)
3~ 690 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey)
IEC: IP00
IEC: IP21
IEC: IP54

www.eaton.eu

Variable frequency drive 9000X

83

SVX, for three-phase motors 400 V AC

Ordering
SVX, for three-phase motors 400 V AC

Protection
type

Part no.
Article no.

FR4

IP21

SVX001A1-4A1B1
125676
SVX001A2-4A1B1
125677

L = 110 %

H = 150 %

Ie

Ie

P

P

Ie

Ie

A

A

kW

kW

A

A

Brake chopper

Frame size

Assigned motor
rating 1), 2)
L = 110 % H = 150 %

Radio interference
suppression filter

Rated motor current1), 2) Fitted with

Rated operational
current1)
L = 110 %
H = 150 %

1.9

✓

✓

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

Price
see price
list

Std. pack

Mains voltage (50/60Hz) ULN: 380 (-15%) - 500 (+10%) V
3.3
2.2
1.1
0.75
2.6

4.3

5.6

7.6

9

12

16

23

31

38

46

61

72

Notes

3.3

4.3

5.6

7.6

9

12

16

23

31

38

46

61

1) L

1.5

2.2

3

4

5.5

7.5

11

15

18.5

22

30

37

1.1

1.5

2.2

3

4

5.5

7.5

11

15

18.5

22

30

3.6

5

6.6

8.5

11.3

15.2

21.7

29.3

36

41

55

68

2.6

3.6

5

6.6

8.5

11.3

15.2

21.7

29.3

36

41

55

FR5

FR6

FR7

IP21

IP21

IP21

1 off

SVXF15A1-4A1B1
125707
SVXF15A2-4A1B1
125708
SVX002A1-4A1B1
125748
SVX002A2-4A1B1
125678
SVX003A1-4A1B1
125679
SVX003A2-4A1B1
125680
SVX005A1-4A1B1
125749
SVX005A2-4A1B1
125753
SVX006A1-4A1B1
125682
SVX006A2-4A1B1
125683
SVX007A1-4A1B1
125684
SVX007A2-4A1B1
125685
SVX010A1-4A1B1
125686
SVX010A2-4A1B1
125687
SVX015A1-4A1B1
125688
SVX015A2-4A1B1
125689
SVX020A1-4A1B1
125690
SVX020A2-4A1B1
125754
SVX025A1-4A1B1
125691
SVX025A2-4A1B1
125692
SVX030A1-4A1B1
125693
SVX030A2-4A1B1
125694
SVX040A1-4A1N1
125695
SVX040A2-4A1N1
125696
SVX040A1-4A1B1
132656
SVX040A2-4A1B1
138452

= 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → Page 82
CA04020001Z-EN-INT
www.eaton.eu

SVX, SPX

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase

84

Variable frequency drive 9000X
SVX, for three-phase motors 400 V AC

Protection
type

Part no.
Article no.

FR7

IP21

SVX050A1-4A1B1
138430
SVX050A2-4A1N1
125697
SVX050A1-4A1N1
125750
SVX050A2-4A1B1
138453

L = 110 %

H = 150 %

Ie

Ie

P

P

Ie

Ie

A

A

kW

kW

A

A

Brake chopper

Frame size

Assigned motor
rating 1), 2)
L = 110 % H = 150 %

Radio interference
suppression filter

Rated motor current1), 2) Fitted with

Rated operational
current1)
L = 110 %
H = 150 %

Mains voltage (50/60Hz) ULN: 380 (-15%) - 500 (+10%) V
87
72
45
37
81

68

✓

✓

✓

-

IP54

✓

-

IP21

✓

✓

IP54

✓

-

IP54

✓

✓

IP54

✓

✓

IP21

✓

-

IP21

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

✓

-

IP54

✓

✓

IP54

✓

✓

IP21

✓

-

IP21

✓

-

IP54

✓

✓

IP54

✓

✓

IP21

Price
see price
list

Std. pack

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase

105

140

170

205

261

300

Notes

87

105

140

170

205

245

55

75

90

110

132

160

45

55

75

90

110

132

1) L

99

134

161

196

231

279

81

99

134

161

196

231

FR8

FR9

IP21

IP21

1 off

SVX060A2-4A1N1
125698
SVX060A2-4A1B1
138454
SVX060A1-4A1B1
138431
SVX060A1-4A1N1
125751
SVX075A1-4A1N1
125699
SVX075A2-4A1N1
125700
SVX075A1-4A1B1
132657
SVX075A2-4A1B1
138455
SVX100A1-4A1N1
125701
SVX100A2-4A1N1
125755
SVX100A1-4A1B1
132658
SVX100A2-4A1B1
138456
SVX125A1-4A1N1
125702
SVX125A2-4A1N1
125703
SVX125A1-4A1B1
135242
SVX125A2-4A1B1
138457
SVX150A1-4A1N1
125704
SVX150A2-4A1N1
125705
SVX150A2-4A1B1
138458
SVX150A1-4A1B1
138432
SVX200A1-4A1N1
125752
SVX200A2-4A1N1
125706
SVX200A2-4A1B1
138459
SVX200A1-4A1B1
132900

= 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → Page 82

CA04020001Z-EN-INT

www.eaton.eu

Variable frequency drive 9000X

85

SVX, for three-phase motors 690 V AC
SVX, for three-phase motors 690 V AC

Protection
type

Part no.
Article no.

FR6

IP21

SVX002A1-5A4N1
125756
SVX002A2-5A4N1
125774
SVX002A2-5A4B1
138498
SVX002A1-5A4B1
138480

L = 110 %

H = 150 %

Ie

Ie

P

P

Ie

Ie

A

A

kW

kW

A

A

Brake chopper

Frame size

Assigned motor
rating 1), 2)
L = 110 % H = 150 %

Radio interference
suppression filter

Rated motor current1), 2) Fitted with

Rated operational
current1)
H = 150 %
L = 110 %

2.9

✓

-

✓

-

IP54

✓

✓

IP54

✓

✓

IP21

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

Price
see price
list

Std. pack

Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase

5.5

7.5

10

13.5

18

22

Notes

4.5

5.5

7.5

10

13.5

18

4

5.5

7.5

11

15

18.5

3

4

5.5

7.5

11

15

4.9

6.5

8.8

12.6

17

20.9

3.8

4.9

6.5

8.8

12.6

17

1 off

SVX, SPX

Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V
4.5
3.2
3
2.2
3.8

SVX003A1-5A4N1
125757
SVX003A2-5A4N1
125775
SVX003A1-5A4B1
138481
SVX003A2-5A4B1
138499
SVX004A1-5A4N1
125758
SVX004A2-5A4N1
125776
SVX004A1-5A4B1
138482
SVX004A2-5A4B1
138500
SVX005A1-5A4N1
125759
SVX005A2-5A4N1
125777
SVX005A1-5A4B1
138483
SVX005A2-5A4B1
138501
SVX007A1-5A4N1
125760
SVX007A2-5A4N1
125778
SVX007A1-5A4B1
138484
SVX007A2-5A4B1
138502
SVX010A1-5A4N1
125761
SVX010A2-5A4N1
125779
SVX010A1-5A4B1
138485
SVX010A2-5A4B1
138503
SVX015A1-5A4N1
125762
SVX015A2-5A4N1
125780
SVX015A1-5A4B1
138486
SVX015A2-5A4B1
138504

1) L

= 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → Page 82

2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

86

Variable frequency drive 9000X
SVX, for three-phase motors 690 V AC

Protection
type

Part no.
Article no.

FR6

IP21

SVX020A1-5A4N1
125763
SVX020A2-5A4N1
125781
SVX020A1-5A4B1
138487
SVX020A2-5A4B1
138505

L = 110 %

H = 150 %

Ie

Ie

P

P

Ie

Ie

A

A

kW

kW

A

A

Brake chopper

Frame size

Assigned motor
rating 1), 2)
L = 110 % H = 150 %

Radio interference
suppression filter

Rated motor current1), 2) Fitted with

Rated operational
current1)
L = 110 %
H = 150 %

20.9

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP54

✓

-

IP21

✓

✓

IP21

✓

✓

IP54

✓

-

✓

-

IP54

✓

✓

IP54

✓

✓

IP21

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

Price
see price
list

Std. pack

Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase
Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V
27
22
22
18.5
23.8

34

41

52

62

80

100

Notes

27

34

41

52

62

80

30

37

45

55

75

90

22

30

37

45

55

75

1) L

32

39

47

58

78

93

23.8

32

39

47

58

78

FR7

FR8

IP21

IP21

1 off

SVX025A1-5A4N1
125764
SVX025A2-5A4N1
125782
SVX025A1-5A4B1
138488
SVX025A2-5A4B1
138506
SVX030A1-5A4N1
125765
SVX030A2-5A4N1
125783
SVX030A1-5A4B1
138489
SVX030A2-5A4B1
138507
SVX040A2-5A4N1
125784
SVX040A1-5A4N1
125766
SVX040A1-5A4B1
138490
SVX040A2-5A4B1
138508
SVX050A1-5A4N1
125767
SVX050A2-5A4N1
125785
SVX050A2-5A4B1
138509
SVX050A1-5A4B1
138491
SVX060A1-5A4N1
125768
SVX060A2-5A4N1
125786
SVX060A1-5A4B1
138492
SVX060A2-5A4B1
138510
SVX075A1-5A4N1
125769
SVX075A2-5A4N1
125787
SVX075A1-5A4B1
138493
SVX075A2-5A4B1
138511

= 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → Page 82

CA04020001Z-EN-INT

www.eaton.eu

Variable frequency drive 9000X

87

SVX, for three-phase motors 690 V AC

Protection
type

Part no.
Article no.

FR9

IP21

SVX100A1-5A4N1
125770
SVX100A2-5A4N1
125788
SVX100A1-5A4B1
138494
SVX100A2-5A4B1
138512

L = 110 %

H = 150 %

Ie

Ie

P

P

Ie

Ie

A

A

kW

kW

A

A

Brake chopper

Frame size

Assigned motor
rating 1), 2)
L = 110 % H = 150 %

Radio interference
suppression filter

Rated motor current1), 2) Fitted with

Rated operational
current1)
L = 110 %
H = 150 %

93

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP54

✓

✓

IP21

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

Price
see price
list

Std. pack

Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase

144

170

208

Notes

125

144

170

132

160

200

110

132

160

134

162

202

114

134

162

1 off

SVX, SPX

Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V
125
100
110
90
114

SVX125A1-5A4N1
125771
SVX125A2-5A4N1
125789
SVX125A2-5A4B1
138513
SVX125A1-5A4B1
138495
SVX150A1-5A4N1
125772
SVX150A2-5A4N1
125790
SVX150A1-5A4B1
138496
SVX150A2-5A4B1
138514
SVX175A1-5A4N1
125773
SVX175A2-5A4N1
125791
SVX175A1-5A4B1
138497
SVX175A2-5A4B1
138515

1) L

= 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → Page 82

2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

88

Variable frequency drive 9000X
SPX, for three-phase motors 400 V AC

SPX, for three-phase motors 400 V AC

Protection
type

Part no.
Article no.

FR4

IP21

SPX001A1-4A1B1
125203
SPX001A2-4A1B1
125207

L = 110 %

H = 150 %

Ie

Ie

P

P

Ie

Ie

A

A

kW

kW

A

A

Brake chopper

Frame size

Assigned motor
rating 1), 2)
L = 110 % H = 150 %

Radio interference
suppression filter

Rated motor current1), 2) Fitted with

Rated operational
current1)
H = 150 %
L = 110 %

1.9

✓

✓

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

Price
see price
list

Std. pack

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase

Mains voltage (50/60Hz) ULN: 380 (-15%) - 500 (+10%) V
3.3
2.2
1.1
0.75
2.6

4.3

5.6

7.6

9

12

16

23

31

38

46

61

72

Notes

3.3

4.3

5.6

7.6

9

12

16

23

31

38

46

61

1.5

2.2

3

4

5.5

7.5

11

15

18.5

22

30

37

1.1

1.5

2.2

3

4

5.5

7.5

11

15

18.5

22

30

1) L

3.6

5

6.6

8.5

11.3

15.2

21.7

29.3

36

41

55

68

2.6

3.6

5

6.6

8.5

11.3

15.2

21.7

29.3

36

41

55

FR5

FR6

FR7

IP21

IP21

IP21

1 off

SPXF15A1-4A1B1
125675
SPXF15A2-4A1B1
125480
SPX002A1-4A1B1
125657
SPX002A2-4A1B1
125216
SPX003A1-4A1B1
125658
SPX003A2-4A1B1
125226
SPX005A1-4A1B1
125659
SPX005A2-4A1B1
125245
SPX006A1-4A1B1
125249
SPX006A2-4A1B1
125251
SPX007A1-4A1B1
125660
SPX007A2-4A1B1
125260
SPX010A1-4A1B1
125661
SPX010A2-4A1B1
125662
SPX015A1-4A1B1
125663
SPX015A2-4A1B1
125664
SPX020A1-4A1B1
125665
SPX020A2-4A1B1
125291
SPX025A1-4A1B1
125666
SPX025A2-4A1B1
125302
SPX030A1-4A1B1
125667
SPX030A2-4A1B1
125313
SPX040A1-4A1N1
125319
SPX040A2-4A1N1
125325
SPX040A1-4A1B1
134844
SPX040A2-4A1B1
138609

= 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → Page 82

CA04020001Z-EN-INT

www.eaton.eu

Variable frequency drive 9000X

89

SPX, for three-phase motors 400 V AC

Protection
type

Part no.
Article no.

FR7

IP21

SPX050A1-4A1N1
125331
SPX050A2-4A1N1
125337
SPX050A1-4A1B1
138606
SPX050A2-4A1B1
138610

L = 110 %

H = 150 %

Ie

Ie

P

P

Ie

Ie

A

A

kW

kW

A

A

Brake chopper

Frame size

Assigned motor
rating 1), 2)
L = 110 % H = 150 %

Radio interference
suppression filter

Rated motor current1), 2) Fitted with

Rated operational
current1)
L = 110 %
H = 150 %

Mains voltage (50/60Hz) ULN: 380 (-15%) - 500 (+10%) V
87
72
45
37
81

68

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

Price
see price
list

Std. pack

Ue 400 V AC, 3-phase / U2 400 V AC, 3-phase

105

140

170

205

261

300

Notes

87

105

140

170

205

245

55

75

90

110

132

160

45

55

75

90

110

132

99

134

161

196

231

279

81

99

134

161

196

231

FR8

FR9

IP21

IP21

SVX, SPX

1 off

SPX060A1-4A1N1
125668
SPX060A2-4A1N1
125348
SPX060A1-4A1B1
138607
SPX060A2-4A1B1
138611
SPX075A1-4A1N1
125354
SPX075A2-4A1N1
125359
SPX075A1-4A1B1
138608
SPX075A2-4A1B1
138612
SPX100A1-4A1N1
125365
SPX100A2-4A1N1
125370
SPX100A1-4A1B1
131744
SPX100A2-4A1B1
138613
SPX125A1-4A1N1
125669
SPX125A2-4A1N1
125377
SPX125A1-4A1B1
134489
SPX125A2-4A1B1
138614
SPX150A1-4A1N1
125381
SPX150A2-4A1N1
125385
SPX150A1-4A1B1
129701
SPX150A2-4A1B1
138615
SPX200A1-4A1N1
125670
SPX200A2-4A1N1
125398
SPX200A1-4A1B1
134845
SPX200A2-4A1B1
138616

1) L

= 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → Page 82

2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

90

Variable frequency drive 9000X
SPX, for three-phase motors 690 V AC

SPX, for three-phase motors 690 V AC

Protection
type

Part no.
Article no.

FR6

IP21

SPX002A1-5A4N1
125212
SPX002A2-5A4N1
125218
SPX002A1-5A4B1
138638
SPX002A2-5A4B1
129582

L = 110 %

H = 150 %

Ie

Ie

P

P

Ie

Ie

A

A

kW

kW

A

A

Brake chopper

Frame size

Assigned motor
rating 1), 2)
L = 110 % H = 150 %

Radio interference
suppression filter

Rated motor current1), 2) Fitted with

Rated operational
current1)
H = 150 %
L = 110 %

2.9

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP54

✓

-

IP21

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

✓

IP54

✓

✓

IP21

✓

-

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

Price
see price
list

Std. pack

Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase

Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V
4.5
3.2
3
2.2
3.8

5.5

7.5

10

13.5

18

22

Notes

4.5

4

5.5

5.5

7.5

7.5

10

11

13.5

15

18

18.5

3

4

5.5

7.5

11

15

1) L

4.9

6.5

8.8

12.6

17

20.9

3.8

4.9

6.5

8.8

12.6

17

1 off

SPX003A2-5A4N1
125228
SPX003A1-5A4N1
125222
SPX003A1-5A4B1
138639
SPX003A2-5A4B1
129583
SPX004A1-5A4N1
125232
SPX004A2-5A4B1
129584
SPX004A1-5A4B1
138640
SPX004A2-5A4N1
125236
SPX005A1-5A4N1
125241
SPX005A2-5A4N1
125247
SPX005A1-5A4B1
138641
SPX005A2-5A4B1
129585
SPX007A1-5A4N1
125256
SPX007A2-5A4N1
125262
SPX007A1-5A4B1
138642
SPX007A2-5A4B1
129586
SPX010A1-5A4N1
125267
SPX010A2-5A4N1
125272
SPX010A1-5A4B1
138643
SPX010A2-5A4B1
129587
SPX015A1-5A4N1
125277
SPX015A2-5A4N1
125282
SPX015A1-5A4B1
138644
SPX015A2-5A4B1
129588

= 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → Page 82

2) Assigned

CA04020001Z-EN-INT

www.eaton.eu

Variable frequency drive 9000X

91

SPX, for three-phase motors 690 V AC

Protection
type

Part no.
Article no.

FR6

IP21

SPX020A1-5A4N1
125287
SPX020A2-5A4N1
125293
SPX020A1-5A4B1
138645
SPX020A2-5A4B1
129589

L = 110 %

H = 150 %

Ie

Ie

P

P

Ie

Ie

A

A

kW

kW

A

A

Brake chopper

Frame size

Assigned motor
rating 1), 2)
L = 110 % H = 150 %

Radio interference
suppression filter

Rated motor current1), 2) Fitted with

Rated operational
current1)
L = 110 %
H = 150 %

20.9

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP54

✓

✓

IP21

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP54

✓

✓

IP21

Price
see price
list

Std. pack

Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase

34

41

52

62

80

100

Notes

27

34

41

52

62

80

30

37

45

55

75

90

22

30

37

45

55

75

32

39

47

58

78

93

23.8

32

39

47

58

78

FR7

FR8

IP21

IP21

1 off

SVX, SPX

Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V
27
22
22
18.5
23.8

SPX025A1-5A4N1
125298
SPX025A2-5A4N1
125304
SPX025A2-5A4B1
129590
SPX025A1-5A4B1
138646
SPX030A1-5A4N1
125309
SPX030A2-5A4N1
125315
SPX030A1-5A4B1
138647
SPX030A2-5A4B1
129591
SPX040A1-5A4N1
125321
SPX040A2-5A4N1
125327
SPX040A1-5A4B1
138648
SPX040A2-5A4B1
129592
SPX050A1-5A4N1
125333
SPX050A2-5A4N1
125339
SPX050A1-5A4B1
138649
SPX050A2-5A4B1
129593
SPX060A1-5A4N1
125344
SPX060A2-5A4N1
125350
SPX060A1-5A4B1
138650
SPX060A2-5A4B1
129594
SPX075A1-5A4N1
125356
SPX075A2-5A4N1
125361
SPX075A2-5A4B1
129595
SPX075A1-5A4B1
138651

1) L

= 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
2) Assigned motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → Page 82

CA04020001Z-EN-INT

www.eaton.eu

92

Variable frequency drive 9000X
SPX, for three-phase motors 690 V AC, Accessories

Protection
type

Part no.
Article no.

FR9

IP21

SPX100A1-5A4N1
125367
SPX100A2-5A4N1
125372
SPX100A1-5A4B1
138652
SPX100A2-5A4B1
129596

L = 110 %

H = 150 %

Ie

Ie

P

P

Ie

Ie

A

A

kW

kW

A

A

Brake chopper

Frame size

Assigned motor
rating 1), 2)
L = 110 % H = 150 %

Radio interference
suppression filter

Rated motor current1), 2) Fitted with

Rated operational
current1)
L = 110 %
H = 150 %

93

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

✓

-

IP21

✓

-

IP54

✓

✓

IP21

✓

✓

IP54

Price
see price
list

Std. pack

Ue 690 V AC, 3-phase / U2 690 V AC, 3-phase
Mains voltage (50/60Hz) ULN: 525 (-15%) - 690 (±10%) V
125
100
110
90
114

144

170

208

Notes

125

132

144

160

170

200

110

132

160

134

162

202

114

134

162

FR9

IP21

1 off

SPX125A1-5A4N1
125375
SPX125A2-5A4N1
125379
SPX125A1-5A4B1
138653
SPX125A2-5A4B1
129597
SPX150A1-5A4N1
125383
SPX150A2-5A4N1
125387
SPX150A1-5A4B1
138654
SPX150A2-5A4B1
129598

1 off

SPX175A1-5A4N1
125389
SPX175A2-5A4N1
125391
SPX175A1-5A4B1
138655
SPX175A2-5A4B1
129599

1) L

= 110% overload for 60 s every 10 min.
H = 150% overload for 60 s every 10 min.
motor rating for normal internally and externally ventilated four-pole, three-phase asynchronous motors with 1500 rpm (at 50 Hz)
or 1800 rpm (at 60 Hz)
Information relevant for export to North America → Page 82

2) Assigned

Accessories
SPX, for three-phase motors 690 V AC, Accessories

Description

For use with

Part no.
Article no.

Price
see price
list

Std. pack

Information relevant for export to North
America

With illuminated LCD display
Plain text, multi-line
With control buttons and
function keys
Front IP54

SVX, SPX

KEYPAD-LOC/REM
139787

1 off

Product Standards

Mounting frame for control
panel door 3 m

KEYPADLOC/REM

OPTRMT-KIT
126868

1 off

Connection between variable
frequency drive and PC 1.5 m

SVX, SPX

SVDRIVECABLE
129001

1 off

External keypad

Mounting unit

UL File No.
UL Category
Control No.
CSA File No.

Connection cable
CSA Class No.
North America
Certification
Suitable for

CA04020001Z-EN-INT

www.eaton.eu

UL 508C; CSA-C22.2
No. 14; IEC/EN61800-3;
IEC/EN61800-5; CE
marking
E134360
NMMS, NMMS2,
NMMS7. NMMS8
UL report applies to
both US and Canada
3211-06
UL listed, certified by
UL for use in Canada
Branch circuits

Variable frequency drive 9000X

93

Accessories
Accessories

Description

For use
with

Part no.
Article no.

Price
see price
list

Std. pack

Information relevant for export to North
America

Expansion modules

System bus adapter

SPX

System bus adapter with
CANopen® interface
RS232 adapter

SPX
SPX

Product Standards
OPTD1
125077
OPTD2
125078
OPTD3
125079

1 off
UL File No.
UL Category
Control No.
CSA File No.

Output expansion
1 relay output (NO/NC)
1 relay output (NC)
1 Thermistor input
2 relay outputs (NO/NC)

SPX

OPTA3
125050

SVX, SPX

1 relay output (NO)
5 digital inputs (42 - 240 V AC)
3 relay outputs (NO)

SVX, SPX

1 relay output (NO/NC)
1 relay output (NO)
1 Thermistor input

SVX, SPX

OPTA2
125049
OPTB9
125064
OPTB5
125062
OPTB2
125060

6 digital inputs
External 24 V supply
6 digital inputs
1 digital output
2 analog inputs (mA/V)
1 analog output
3 digital inputs
1 relay output (NO/NC)
1 digital output
6 digital inputs
1 digital output
2 analog inputs (mA/V)
1 analog output
1 analog input (mA, isolated)
2 analog outputs (mA, isolated)

SVX, SPX

HTL (+15 V/24 V)
Master / Slave capability

SVX, SPX

1 off

CSA Class No.
North America
Certification
Suitable for

UL 508C; CSA-C22.2
No. 14; IEC/EN61800-3;
IEC/EN61800-5; CE
marking
E134360
NMMS, NMMS2,
NMMS7. NMMS8
UL report applies to
both US and Canada
3211-06
UL listed, certified by
UL for use in Canada
Branch circuits

I/O expansion

SVX, SPX

OPTB1
125059
OPTA9
125055

1 off

SVX, SPX

OPTAA
125056

SPX

OPTA8
125054

SVX, SPX

OPTB4
125061

SPX

OPTA7
125053

1 off

SVX, SPX

OPTB8
125063

1 off

OPTC2
125067
OPTC3
125068
OPTC4
125069
OPTC6
125710
OPTC5
125070
OPTC7
125071
OPTC8
125072
OPTCI
125075
OPTCJ
125076

1 off

Encoder module

Temperature sensor expansion
3 Pt100
External 24 V supply

Fieldbus modules
The field bus module is plugged into the variable-frequency drive.
Modbus RS485
Screw terminals
PROFIBUS-DP
Screw terminals
LonWorks
Screw terminals
CANopen®
Screw terminals
PROFIBUS-DP
SUB-D 9 pole, socket
DeviceNet
SUB-D 9 pole, socket
Modbus RS485
SUB-D 9 pole, socket
Modbus-TCP
RJ45, 8-pole
BACnet/IP
RJ45, 8-pole

SVX, SPX
SVX, SPX
SVX, SPX
SVX, SPX
SVX, SPX
SVX, SPX
SVX, SPX
SVX, SPX
SVX, SPX

CA04020001Z-EN-INT

www.eaton.eu

SVX, SPX

The expansion module is plugged into the variable-frequency drive.
Adapters

94

Variable frequency drive 9000X

Variable frequency drive 9000X

SVX, SPX (U
U2: 400
(Ue:
400 VV AC,
AC, 3-phase,
3-phase/U2:
400VVAC,
AC,3-phase
3-phase
e: 400

95

(Ue: 400
U2: 400
SVX, SPX (Ue:
400 VV AC,
AC, 3-phase,
3-phase/U2:
400VVAC,
AC,3-phase)
3-phase

Technical data
SVX, SPX (Ue: 400 V AC, 3-phase/U2: 400 V AC, 3-phase

SVX001…
SPX001…

SVXF15…
SPXF15…

SVX002…
SPX002…

SVX003…
SPX003…

SVX005…
SPX005…

SVX006…
SPX006…

SVX007…
SPX007…

SVX010…
SPX010…

SVX015…
SPX015…

SVX020…
SPX020…

CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

General
Standards
Certifications

EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
CE, cUL, c-Tick
CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
CE, cUL, c-Tick
CE, cUL, c-Tick

Production quality

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

Climatic proofing

RoHS, ISO 9001

RoHS, ISO 9001

ρw

%

< 95% relative humidity, no condensation, no corrosion, no dripping water

< 95% relative humidity, no condensation, no corrosion, no dripping water

Operation

ϑ

°C

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

Storage

ϑ

°C

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

Radio interference level
Radio interference class (EMC)

C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio
interference suppression filters (optional) may be necessary.
1st and 2nd
1st and 2nd
1st and 2nd
1st and 2nd
environments
environments
environments
environments
Vertical
Vertical
Vertical
Vertical

C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.

m

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

kg

5

5

5

5

5

Environment (EMC)
Mounting position
Altitude

Protection against direct contact
Weight

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

Vertical

Vertical

Vertical

Vertical

Vertical

Vertical

5

8.1

8.1

8.1

18.5

Main circuit
Supply
Rated operational voltage

Ue

V

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

Mains voltage (50/60Hz)

ULN

V

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

Output voltage with Ve

U2

V

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

Output Frequency

f2

Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

Switching frequency

fPWM

kHz

10
(adjustable 1 - 16)

10
(adjustable 1 - 16)

10
(adjustable 1 - 16)

10
(adjustable 1 - 16)

10
(adjustable 1 - 16)

10
(adjustable 1 - 16)

10
(adjustable 1 - 16)

10
(adjustable 1 - 16)

10
(adjustable 1 - 16)

10
(adjustable 1 - 16)

0.01

0.01

0.01

0.01

Power section
Function

Frequency inverter with internal DC link and IGBT inverter

Frequency inverter with internal DC link and IGBT inverter

Operation Mode
SVX…

Δf

Hz

U/f control
sensorless vector control (SLV)
U/f control
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.01
0.01

At 110% overload

Ie

A

3.3

4.3

5.6

7.6

9

12

16

23

31

38

At 150% overload

Ie

A

2.2

3.3

4.3

5.6

7.6

9

12

16

23

31

With 400 V, 50 Hz (110% overload)

P

kW

1.1

1.5

2.2

3

4

5.5

7.5

11

15

18.5

With 400 V, 50 Hz (150% overload)

P

kW

0.75

1.1

1.5

2.2

3

4

5.5

7.5

11

15

With 440 - 480 V, 60 Hz (110% overload)

P

HP

1.5

2

3

5

6

7.5

10

15

20

25

With 440 - 480 V, 60 Hz (150% overload)

P

HP

1

1.5

2

3

5

6

7.5

10

15

20

External control voltage

Uc

V

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

Reference voltage

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

SPX…

Frequency resolution (setpoint value)

0.01

0.01

U/f control
sensorless vector control (SLV)
U/f control
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.01
0.01

Rated operational current

Motor feeder
Assigned motor rating
Note

For AC motors with internal and external ventilation with 50 Hz / 60 Hz

For AC motors with internal and external ventilation with 50 Hz / 60 Hz

Control section

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

SVX, SPX

Ambient temperature

96

Variable frequency drive 9000X

Variable frequency drive 9000X

SVX, SPX (U
U2: 400
(Ue:
400 VV AC,
AC, 3-phase,
3-phase/U2:
400VVAC,
AC,3-phase)
3-phase
e: 400

SVX025…
SPX025…

SVX030…
SPX030…

97

(Ue: 400
U2: 400
SVX, SPX (Ue:
400 VV AC,
AC, 3-phase,
3-phase/U2:
400VVAC,
AC,3-phase)
3-phase

SVX040…
SPX040…

SVX050…
SPX050…

SVX060…
SPX060…

SVX075…
SPX075…

SVX100…
SPX100…

SVX125…
SPX125…

SVX150…
SPX150…

SVX200…
SPX200…

CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

General
Standards
Certifications

EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
CE, cUL, c-Tick
CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
CE, cUL, c-Tick
CE, cUL, c-Tick

Production quality

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

Climatic proofing

RoHS, ISO 9001

RoHS, ISO 9001

ρw

%

< 95% relative humidity, no condensation, no corrosion, no dripping water

< 95% relative humidity, no condensation, no corrosion, no dripping water

Operation

ϑ

°C

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

Storage

ϑ

°C

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

Radio interference level
Radio interference class (EMC)

C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio
interference suppression filters (optional) may be necessary.
1st and 2nd
1st and 2nd
1st and 2nd
1st and 2nd
environments
environments
environments
environments
Vertical
Vertical
Vertical
Vertical

C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.

m

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

kg

18.5

18.5

35

35

35

Environment (EMC)
Mounting position
Altitude

Protection against direct contact
Weight

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

Vertical

Vertical

Vertical

Vertical

Vertical

Vertical

58

58

58

146

146

Main circuit
Supply
Rated operational voltage

Ue

V

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

Mains voltage (50/60Hz)

ULN

V

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

380 (-15%) - 500 (+10%)

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

Output voltage with Ve

U2

V

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

400 V AC, 3-phase

Output Frequency

f2

Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

Switching frequency

fPWM

kHz

10
(adjustable 1 - 16)

10
(adjustable 1 - 16)

3.6
(adjustable 1 - 10)

3.6
(adjustable 1 - 10)

3.6
(adjustable 1 - 10)

3.6
(adjustable 1 - 10)

3.6
(adjustable 1 - 10)

3.6
(adjustable 1 - 10)

3.6
(adjustable 1 - 10)

3.6
(adjustable 1 - 10)

0.01

0.01

0.01

0.01

Power section
Function

Frequency inverter with internal DC link and IGBT inverter

Frequency inverter with internal DC link and IGBT inverter

Operation Mode
SVX…

Δf

Hz

U/f control
sensorless vector control (SLV)
U/f control
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.01
0.01

At 110% overload

Ie

A

46

61

72

87

105

140

170

205

261

300

At 150% overload

Ie

A

38

46

61

72

87

105

140

170

205

245

With 400 V, 50 Hz (110% overload)

P

kW

22

30

37

45

55

75

90

110

132

160

With 400 V, 50 Hz (150% overload)

P

kW

18.5

22

30

37

45

55

75

90

110

132

With 440 - 480 V, 60 Hz (110% overload)

P

HP

30

40

50

60

75

100

125

150

200

250

With 440 - 480 V, 60 Hz (150% overload)

P

HP

25

30

40

50

60

75

100

125

150

200

External control voltage

Uc

V

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

Reference voltage

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

SPX…

Frequency resolution (setpoint value)

0.01

0.01

U/f control
sensorless vector control (SLV)
U/f control
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.01
0.01

Rated operational current

Motor feeder
Assigned motor rating
Note

For AC motors with internal and external ventilation with 50 Hz / 60 Hz

For AC motors with internal and external ventilation with 50 Hz / 60 Hz

Control section

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

SVX, SPX

Ambient temperature

98

Variable frequency drive 9000X

Variable frequency drive 9000X

SVX, SPX (U
U2: 690V
(Ue:
400 VV AC,
AC, 3-phase,
3-phase/U2:
400 VAC,
AC,3-phase)
3-phase
e: 690

SVX002…
SPX002…

SVX003…
SPX003…

99

SVX,SPX
SPX(Ue:
(Ue: 400
690 V AC, 3-phase/U2:
3-phase, U2: 690V
SVX,
400 VAC,
AC,3-phase)
3-phase

SVX004…
SPX004…

SVX005…
SPX005…

SVX007…
SPX007…

SVX010…
SPX010…

SVX015…
SPX015…

SVX020…
SPX020…

SVX025…
SPX025…

SVX030…
SPX030…

CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

General
Standards
Certifications

EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
CE, cUL, c-Tick
CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
CE, cUL, c-Tick
CE, cUL, c-Tick

Production quality

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

Climatic proofing

RoHS, ISO 9001

RoHS, ISO 9001

ρw

%

< 95% relative humidity, no condensation, no corrosion, no dripping water

< 95% relative humidity, no condensation, no corrosion, no dripping water

Operation

ϑ

°C

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

Storage

ϑ

°C

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

Radio interference level
Radio interference class (EMC)

C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio
interference suppression filters (optional) may be necessary.
1st and 2nd
1st and 2nd
1st and 2nd
1st and 2nd
environments
environments
environments
environments
Vertical
Vertical
Vertical
Vertical

C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.

m

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

kg

18.5

18.5

18.5

18.5

18.5

Environment (EMC)
Mounting position
Altitude

Protection against direct contact
Weight

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

1st and 2nd environments

Vertical

Vertical

Vertical

Vertical

Vertical

Vertical

18.5

18.5

18.5

18.5

35

Main circuit
Supply
Rated operational voltage

Ue

V

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

Mains voltage (50/60Hz)

ULN

V

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

Output voltage with Ve

U2

V

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

Output Frequency

f2

Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

Switching frequency

fPWM

kHz

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

0.01

0.01

0.01

0.01

Power section
Function

Frequency inverter with internal DC link and IGBT inverter

Frequency inverter with internal DC link and IGBT inverter

Operation Mode
SVX…

Δf

Hz

U/f control
sensorless vector control (SLV)
U/f control
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.01
0.01

At 110% overload

Ie

A

4.5

5.5

7.5

10

13.5

18

22

27

34

41

At 150% overload

Ie

A

3.2

4.5

5.5

7.5

10

13.5

18

22

27

34

With 690 V, 60 Hz (110% overload)

P

kW

3

4

5.5

7.5

11

15

18.5

22

30

37

With 690 V, 60 Hz (150% overload)

P

kW

2.2

3

4

5.5

7.5

11

15

18.5

22

30

With 550 - 600 V, 60 Hz (110% overload)

P

HP

3

4

5

7.5

10

15

20

25

30

40

With 550 - 600 V, 60 Hz (150% overload)

P

HP

2

3

4

5

7.5

10

15

20

25

30

External control voltage

Uc

V

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

Reference voltage

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

SPX…

Frequency resolution (setpoint value)

0.01

0.01

U/f control
sensorless vector control (SLV)
U/f control
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.01
0.01

Rated operational current

Motor feeder
Assigned motor rating
Note

For AC motors with internal and external ventilation with 50 Hz / 60 Hz

For AC motors with internal and external ventilation with 50 Hz / 60 Hz

Control section

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

SVX, SPX

Ambient temperature

100

Variable frequency drive 9000X

Variable frequency drive 9000X

SVX, SPX (U
U2: 690V
(Ue:
400 VV AC,
AC, 3-phase,
3-phase/U2:
400 VAC,
AC,3-phase)
3-phase
e: 690

SVX040…
SPX040…

SVX050…
SPX050…

101

SVX,SPX
SPX(Ue:
(Ue: 400
690 V AC, 3-phase/U2:
3-phase, U2: 690V
SVX,
400 VAC,
AC,3-phase)
3-phase

SVX060…
SPX060…

SVX075…
SPX075…

SVX100…
SPX100…

SVX125…
SPX125…

SVX150…
SPX150…

SVX175…
SPX175…

SVX200…
SPX200…

CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

General
Standards
Certifications

EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
CE, cUL, c-Tick
CE, cUL, c-Tick

CE, cUL, c-Tick

CE, cUL, c-Tick

EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
CE, cUL, c-Tick
CE, cUL, c-Tick

Production quality

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

RoHS, ISO 9001

Climatic proofing

ρw

RoHS, ISO 9001

%

< 95% relative humidity, no condensation, no corrosion, no dripping water

RoHS, ISO 9001

< 95% relative humidity, no condensation, no corrosion, no dripping water

Ambient temperature
Operation

ϑ

°C

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

-10 - +40

Storage

ϑ

°C

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

-40 - +70

Radio interference class (EMC)

C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio
interference suppression filters (optional) may be necessary.
1st and 2nd
1st and 2nd
1st and 2nd
1st and 2nd
environments
environments
environments
environments
Vertical
Vertical
Vertical
Vertical

C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters
(optional) may be necessary.
1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments 1st and 2nd environments

m

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m
BGV A3 (VBG4, finger- and back-of-hand proof)

kg

35

58

58

58

146

Environment (EMC)
Mounting position
Altitude

Protection against direct contact
Weight

Vertical

Vertical

Vertical

Vertical

Vertical

146

146

146

176

SVX, SPX

Radio interference level

Main circuit
Supply
Rated operational voltage

Ue

V

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

Mains voltage (50/60Hz)

ULN

V

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

525 (-15%) - 690 (±10%)

Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Frequency range

fLN

Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

45 - 66 Hz

Output voltage with Ve

U2

V

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

690 V AC, 3-phase

Output Frequency

f2

Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

0 - 320 Hz

Switching frequency

fPWM

kHz

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

1.5
(adjustable 1 - 6)

0.01

0.01

0.01

Power section
Function

Frequency inverter with internal DC link and IGBT inverter

Frequency inverter with internal DC link and IGBT inverter

Operation Mode
SVX…

Δf

Hz

U/f control
sensorless vector control (SLV)
U/f control
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.01
0.01

At 110% overload

Ie

A

52

62

80

100

125

144

170

208

261

At 150% overload

Ie

A

41

52

62

80

100

125

144

170

208

With 690 V, 60 Hz (110% overload)

P

kW

45

55

75

90

110

132

160

200

250

With 690 V, 60 Hz (150% overload)

P

kW

37

45

55

75

90

110

132

160

200

With 550 - 600 V, 60 Hz (110% overload)

P

HP

50

60

75

100

125

150

175

200

250

With 550 - 600 V, 60 Hz (150% overload)

P

HP

40

50

60

75

100

125

150

175

200

External control voltage

Uc

V

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

24 V DC (max. 250 mA)

Reference voltage

Us

V

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

10 V DC (max. 10 mA)

SPX…

Frequency resolution (setpoint value)

0.01

0.01

U/f control
sensorless vector control (SLV)
U/f control
sensorless vector control (SLV)
Vector control with feedback (CLV)
0.01
0.01

Rated operational current

Motor feeder
Assigned motor rating
Note

For AC motors with internal and external ventilation with 50 Hz / 60 Hz

For AC motors with internal and external ventilation with 50 Hz / 60 Hz

Control section

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

102

Variable frequency drive 9000X
SVX, SPX

Dimensions
SVX, SPX

Sizes FR4 - FR6
Protection type IP20/NEMA 0 and IP20/NEMA 0

⌀1

⌀1

b

b1

⌀2

a1
a

⌀1

c1
c2
c

a
mm (inch)
128 (5)
143 (5.6)
195 (7.6)

a1
mm (inch)
100 (3.9)
100 (3.9)
148 (5.8)

b
mm (inch)
327 (12.9)
419 (16.5)
558 (22)

b1
mm (inch)
313 (12.3)
406 (16)
541 (21.3)

b2
mm (inch)
292 (11.5)
389 (15.3)
519 (20.4)

c
mm (inch)
190 (7.5)
214 (8.4)
237 (9.3)

c1
mm (inch)
77 (3)
100 (3.9)
105 (4.2)

c2
mm (inch)
126 (4.9)
148 (5.9)
165 (6.5)

Sizes FR7
Protection type IP20/NEMA 0 and IP20/NEMA 0

⌀ 9 mm (⌀ 0.4")

⌀ 9 mm (⌀ 0.4")

614 mm (24.2")
630 mm (25.8")

⌀ 18 mm
(⌀ 0.7")

237 mm (9.3")
190 mm (7.5")

CA04020001Z-EN-INT

⌀ 9 mm
(⌀ 0.4")

www.eaton.eu

257 mm (10.1")

35 kg
(77.2 lbs)

Ø1
mm (inch)
7 (0.3)
7 (0.3)
9 (0.4)

Ø2
mm (inch)
13 (0.5)
13 (0.5)
15.5 (0.6)

Weight
kg (lbs)
5 (11)
8 (17.9)
19 (40.8)

Size
FR4
FR5
FR6

Variable frequency drive 9000X

103

SVX, SPX

Sizes FR8
Protection type IP20/NEMA 0 and IP20/NEMA 0

255 mm (10")

⌀ 9 mm (⌀ 0.4")

⌀ 9 mm (⌀ 0.4")

732 mm (28.8")
764 mm (30.1")

SVX, SPX

⌀ 18 mm
(⌀ 0.7")

291 mm (11.5")

344 mm (13.5")

⌀ 9 mm
(⌀ 0.4")

58 kg
(127 lbs)

Sizes FR9
Protection type IP20/NEMA 0 and IP20/NEMA 0
⌀ 9 mm (⌀ 0.4")

⌀ 9 mm (⌀ 0.4")

1120 mm (44.1")
400 mm (15.7")
480 mm (18.9")

1150 mm (45.3")

⌀ 29 mm
(⌀ 0.9")

⌀ 9 mm
(⌀ 0.4")

340 mm (13.4")
362 mm (14.3")

146 kg
(321.9 lbs)

CA04020001Z-EN-INT

www.eaton.eu

DS7 soft starters in xStart system –
Soft to start, powerful in torque
The soft starters have become increasingly established as an alternative to the star-delta
starter. The DS7 replaces the mechanical contactor and extends the function “Motor
soft start”. Motor run-up is soft but still at a higher torque than other available solutions
using the patented method. Extended service intervals and reduced operating costs are
welcomed side effects.
Designed for normal applications such as pumps, fans and small conveyors, the compact
DS7 is ideal. The DS7 is also available with a SmartWire-DT connection to simplify
wiring and enhance functionality as an automation solution.

DS7 soft starters

105

System overview
DS7 soft starters < 32 A

106

DS7 soft starters > 32 A

108

Key to type references
DS7 soft starters

109

Description
DS7 soft starters

110

Ordering
DS7 soft starters

111

Accessories DS7

112

General information on Engineering

116

Design with different load cycles

118

Setting of potentiometer

119

Connection examples

120

Assigned switching and protective elements

122

Technical data
DS7 soft starters

124

Dimensions
DS7 soft starters

130

Superfast semiconductor fuses, Fuse Bases

131

CA04020001Z-EN-INT

www.eaton.eu

DS7

Engineering

106

DS7 soft starters
DS7 < 32 A

System overview
DS7 < 32 A

20

19

26

24

25

21

18

15

22

23

17

16

15
11

12

13

14

7
1
2
3

4
4

5
6

4

7
10
10
9

2 T1 4 T2
6 T3

9

8

CA04020001Z-EN-INT

www.eaton.eu

2 T1 4 T2
6 T3

27

DS7 soft starters

107

DS7 < 32 A

Soft starter DS7 with SmartWire-DT

1

→ page 111

DS7 soft starters in construction size 1 for assigned motor
current up to 12 A

15

Standard auxiliary contact
→ Industrial Switchgear 2011 catalog, chapter 7

2

Early-make auxiliary contact

16

→ Industrial Switchgear 2011 catalog, chapter 7

→ page 111
17

Door coupling handle
3

→ page 111

DS7-FAN-32 device fan

PKZM0 motor-protective circuit-breakers
4

→ page 115

SmartWire-DT gateway

5

6

SmartWire-DT flat band conductor

overload relay

7

8

9

10

11, 12

13

three-phase commoning link

26

→ page 113

top-hat rail adapter
14

25

→ Industrial Switchgear 2011 catalog, chapter 8

Busbar adapter

→ page 113

24

→ Industrial Switchgear 2011 catalog, chapter 8

Motor-starter combination with PKE

→ page 113

PKZM0-XM wiring set

23

→ Industrial Switchgear 2011 catalog, chapter 7

Motor-starter combination with PKZ

→ page 113

PKZM0-XDM wiring set in tool-less plug connection

22

→ Industrial Switchgear 2011 catalog, chapter 7

Standard auxiliary contact

→ page 113

Base for motor plugs

21

→ Industrial Switchgear 2011 catalog, chapter 7

trip indicator switch

→ page 113

Motor plugs in tool-less plug connection

20

→ Industrial Switchgear 2011 catalog, chapter 7

Voltage release

→ page 182

19

→ Industrial Switchgear 2011 catalog, chapter 7

Extension terminal

→ page 182

18

→ Industrial Switchgear 2011 catalog, chapter 7

PKE motor-protective circuit-breakers

→ page 182

SmartWire-DT external device plug

→ Industrial Switchgear 2011 catalog, chapter 7

27

→ page 113

→ page 114

CA04020001Z-EN-INT

www.eaton.eu

DS7

DS7 soft starters in construction size 2 for assigned motor
current up to 32 A

108

DS7 soft starters
DS7 > 32 A

DS7 > 32 A

11
10

16

12
15
17

18
7

13

19

23

14

22

20
21

6
5

4

1
2
7
3
10

9

8

CA04020001Z-EN-INT

www.eaton.eu

DS7 soft starters

109

DS7 > 32 A
1

DS7 with SmartWire-DT

Standard auxiliary contact/Trip-indicating auxiliary switch

→ page 111

13

→ Industrial Switchgear 2011 catalog, chapter 17

DS7 size 4 up to 200 A

NZM communication module for SmartWire-DT

2

→ page 111

14

→ Industrial Switchgear 2011 catalog, chapter 17
3

DS7 size 3 up to 100 A

data management interface (DMI module)

→ page 111

15

→ Industrial Switchgear 2011 catalog, chapter 17

Device fan

Voltage release/Early-make auxiliary contact

4

→ page 115

16

→ Industrial Switchgear 2011 catalog, chapter 17

Superfast semiconductor fuses

Terminal cover for terminals

5

→ page 112

17

→ page 114

Fuse bases for superfast semiconductor fuses

6

IP2X protection against contact with a finger

→ page 113

18

→ page 115

IP2X protection against contact with a finger

Terminal cover for cable lugs

7

→ page 115

19

→ page 114

connection width extension

8

9

Gateways for SmartWire-DT

20

→ Industrial Switchgear 2011 catalog, chapter 17
21

Control circuit terminal

→ page 182

→ Industrial Switchgear 2011 catalog, chapter 17

SmartWire-DT external device plug

Box terminals

10

→ page 182

22

→ Industrial Switchgear 2011 catalog, chapter 17
11

NZM circuit-breaker

Tunnel terminals for Al and Cu cable

→ Industrial Switchgear 2011 catalog, chapter 17

23

→ Industrial Switchgear 2011 catalog, chapter 17
12

spacer
→ Industrial Switchgear 2011 catalog, chapter 17

Key to type references
DS7 > 32 A

DS7 - 3 4 0 SX 004

N

0 -N

Device series

Options

Generation 7

N = No option
D = SmartWire-DT
L = Expanded temperature range down to -40 °C

Number of phases
3 = Three-phase mains
supply voltage

Protection type
0 = IP20

Voltage class
4 = 400 V (380 V - 15 % to
480 V + 10 %)

Radio interference suppression filters
N = No internal radio interference
suppression filter

Control voltage supply
0 = 24 V AC/DC
2 = 110/230 V AC
D = 24 V DC SmartWire-DT

Rated operational current
004 = 4 A
:
200 = 200 A

Device version
SX = Standard soft starters
with internal bypass

CA04020001Z-EN-INT

www.eaton.eu

DS7

overload relay
→ Industrial Switchgear 2011 catalog, chapter 6

110

DS7 soft starters
System

Description
System

Application

Features

The DS7 series soft starters are twophased controlled soft starters used
for soft starting three-phase AC
motors for applications with a normal
operating frequency and a
performance range of 3 to 200 A (1.1 to
110 kW with a 400 V mains voltage).
Closing transients and DC components
during startup are effectively
suppressed and guarantee even motor
starting.
The special actuation method
(asymmetrical trigger phase control)
for the soft starter function avoids the
DC components (Eaton patent) that
would normally occur in two-phasecontrolled soft starters. This
suppresses the generation of an
elliptical rotating field, which would
cause uneven motor starting and
increase the motor's acceleration. The
true run behavior of the DS7 is
therefore comparable with that of a
three-phase controlled soft starter.

• The ramp time can be adjusted by
potentiometer within a range of 1 to
30 s (for starting) or 0 to 30 s (for
stopping) with a potentiometer
• The start voltage (or start torque)
can be adjusted within a range of 30
to 100 percent of the mains voltage
with a potentiometer
• Significant reduction in switch-on
current, achieved with a short soft
start ramp time (min. 1 s) for lamp
and heating loads
• Internal bypass relay: switches on
automatically after the end of the
ramp, bypassing the internal
thyristors.
• This makes it possible to comply
with radio interference level B
without any additional measures.
• The motor's thermal load is smaller
than it would be without asymmetric
ignition control.
• Designed specifically for long
cables

Functions

Documentation

Typical fields of application for Series
DS7 soft starters are:
• Pump drives: pressure surges are
prevented through soft starting. The
mechanical load on the whole plant
is reduced and its service life
increases.
• Fan drives: soft starting keeps fan
belts from slipping, preventing
premature wear. This lowers
operating costs and extends the
system's lifespan.
• Conveyor belts: conveyor belts start
running smoothly, instead of starting
with a jolt. This ensures that any
goods being conveyed do not topple
over. Mechanical damage to the
belt itself is avoided, making it more
durable.

Surface mounting and standard
mounting procedures are described in
the corresponding mounting
instructions and in the manual.

CA04020001Z-EN-INT

www.eaton.eu

Instructional leaflets:
IL03902003Z: for size 1 devices
(up to 12 A motor output)
IL03902004Z: for size 2 devices
(up to 32 A motor output)
IL03902005Z: for size 3, 4 devices
(up to 200 A motor output)
Manual:
MN03901001Z
You can download the documentation
for the DS7 soft starters from the
Internet
at: www.moeller.net/support

Communication interface
SmartWire-DT
Our SmartWire-DT interface
completely eliminates the need for
conventional control wiring. This has
several advantages:
• No incorrect wiring
• Faster wiring
• Cost saving
The interface can be used to send
control commands to the DS7-SWD
and change and diagnose its
parameter configuration; in addition,
the control electronics can be
powered via the SmartWire-DT cable.
The device is controlled with one of
three selectable profiles:
• A "start/stop" profile, which should
already be familiar from the PKE
motor-protective circuit-breaker
and contactor combination
• An 8 bit-wide profile for the soft
starter, which is provided the same
way for the variable frequency drive
and features more options
• A control profile comparable to a
PROFIdrive profile, just like the one
available for the variable frequency
drive.
Regardless of the profile chosen, the
DS7-SWD's parameters can be read
and written to at any time by using
acyclic services.
DS7-SWD makes it possible to read
and write to all device parameters. The
mechanisms of the parameter channel
that is described for the drives in the
PROFIdrive profile are used for this
purpose. This profile provides a
standardized parameter access
method for variable frequency drives
and soft starters.
It is also possible to overwrite the
potentiometer settings on the
DS7-SWD, which can come in handy,
for instance, when a change made to
the machine needs to be undone.

The DS7-SWD comes with a detailed
diagnostic system with options that
extend far beyond those of wired
devices. In addition to having an error
log, the DS7-SWD can detect and
report nine different device faults. A
warning parameter reports any
present alarm messages. Moreover,
the response to each individual fault
can be customized. Finally, there are
35 additional messages for
communication errors. Using the DS7
in connection with the PKE opens up
new functionalities that were
previously thought impossible to
implement with a low-cost soft starter
and that were reserved to significantly
more expensive devices. Combining a
PKE unit and a DS7-SWD makes it
possible to completely protect the
DS7-SWD device against overloads. In
addition, it provides a current limiting
function and can report thermal
capacity utilization levels to higher
level controllers.

Expanded temperature range
DS7-340SX…-L soft starters can
operate at temperatures as low
as -40 °C.

DS7 soft starters

111

Basic devices

Ordering
Basic devices

Rated
operational
current
Device (AC53)
Ie

Assigned motor rating

at 400 V,
50 Hz
P

at 480 V,
60 Hz
P

A

kW

HP

Part no.

Article no.

Price
see price
list

Part no.

Article no.

Price
see price
list

UC 24 V AC/DC
Us 24 V AC/DC
Standard temperature range

UC 24 V AC/DC
Us 24 V AC/DC
Expanded temperature range down to -40 °C

Std. pack

Soft starters
Soft starters for three-phase loads
Mains supply voltage (50/60 Hz)
ULN 200 - 480 V AC
1.5

2

DS7-340SX004N0-N

134847

DS7-340SX004N0-L

171740

7

3

5

DS7-340SX007N0-N

134849

DS7-340SX007N0-L

171741

9

4

5

DS7-340SX009N0-N

134910

DS7-340SX009N0-L

171742

12

5.5

10

DS7-340SX012N0-N

134911

DS7-340SX012N0-L

171743

16

7.5

10

DS7-340SX016N0-N

134912

DS7-340SX016N0-L

171744

24

11

15

DS7-340SX024N0-N

134913

DS7-340SX024N0-L

171745

32

15

25

DS7-340SX032N0-N

134914

DS7-340SX032N0-L

171746

41

22

30

DS7-340SX041N0-N

134916

DS7-340SX041N0-L

171747

55

30

40

DS7-340SX055N0-N

134917

DS7-340SX055N0-L

171748

70

37

50

DS7-340SX070N0-N

134918

DS7-340SX070N0-L

171749

81

45

60

DS7-340SX081N0-N

134919

DS7-340SX081N0-L

171750

100

55

75

DS7-340SX100N0-N

134920

DS7-340SX100N0-L

171751

135

75

100

DS7-340SX135N0-N

134921

DS7-340SX135N0-L

171752

160

90

125

DS7-340SX160N0-N

134922

DS7-340SX160N0-L

171753

200

110

150

DS7-340SX200N0-N

134923

DS7-340SX200N0-L

171754

UC 110 - 230 V AC
Us 110/230 V AC

1 off

DS7

4

UC 24 V DC
Us 24 V DC

4

1.5

2

DS7-342SX004N0-N

134925

DS7-34DSX004N0-D

134943

7

3

5

DS7-342SX007N0-N

134927

DS7-34DSX007N0-D

134945

9

4

5

DS7-342SX009N0-N

134928

DS7-34DSX009N0-D

134946

12

5.5

10

DS7-342SX012N0-N

134929

DS7-34DSX012N0-D

134947

16

7.5

10

DS7-342SX016N0-N

134930

DS7-34DSX016N0-D

134948

24

11

15

DS7-342SX024N0-N

134931

DS7-34DSX024N0-D

134949

32

15

25

DS7-342SX032N0-N

134932

DS7-34DSX032N0-D

134950

41

22

30

DS7-342SX041N0-N

134934

DS7-34DSX041N0-D

134952

55

30

40

DS7-342SX055N0-N

134935

DS7-34DSX055N0-D

134953

70

37

50

DS7-342SX070N0-N

134936

DS7-34DSX070N0-D

134954

81

45

60

DS7-342SX081N0-N

134937

DS7-34DSX081N0-D

134955

100

55

75

DS7-342SX100N0-N

134938

DS7-34DSX100N0-D

134956

135

75

100

DS7-342SX135N0-N

134939

DS7-34DSX135N0-D

134957

160

90

125

DS7-342SX160N0-N

134940

DS7-34DSX160N0-D

134958

200

110

150

DS7-342SX200N0-N

134941

DS7-34DSX200N0-D

134959

Notes

1 off

Information relevant for export to North America
UL/CSA applies only for DS7…-N
Product Standards
UL File No.
CSA File No.
CSA Class No.
Suitable for
Max. Voltage Rating
Degree of Protection

4 - 12 A

16 - 32 A

41 - 100 A

IEC/EN 60947-4-2; GB 14048.6; UL 508;
CSA-C22.2 No 0-M91; CSA-C22.2 No 14-05 CE
marking
E251034
2511305
321106
Branch circuits
480 V
IP20; UL/CSA Type 1

135 - 200 A
CA04020001Z-EN-INT

www.eaton.eu

112

DS7 soft starters
Accessories

Accessories

Frame size

For use with

Part no.
Article no.

DIN 43653, 690/700 V (IEC/UL)
Inside micrometer 80 mm
16
5.5

000

DS7-34…SX004N0-…

25

9

000

DS7-34…SX007N0-…

32

10

000

40

12

000

DS7-34…SX009N0-…
DS7-34…SX012N0-…
DM4-340-7K5

50

15

000

170M1359
171968
170M1361
171969
170M1362
171970
170M1363
171971
170M1364
171972

63

16

000

80

19

000

100

21

S1*

125

25

000

Rated
device
current

Maximum
power
loss
Pv

A

W

Price
see price
list

Std. pack

Information relevant for export to North
America

1 off

Product Standards

Superfast semiconductor fuses

DS4-340-2K2-M
DS4-340-2K2-MR
DS4-340-2K2-M-DC
DS7-34…SX016N0-…
DS4-340-4K0-M
DS4-340-4K0-MR
DS4-340-7K5-MX
DS4-340-7K5-MXR
DS7-34…SX024N0-…
DS4-340-5K5-M
DS4-340-5K5-MR
DS4-340-11K-MX
DS4-340-11K-MXR
DS7-34…SX032N0-…
DS6-340-22K-MX
DM4-340-22K
DM4-340-30K

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification
Suitable for

170M1365
171973

30

S1*

200

45

S1

315

58

S1

350

60

S1

400

65

S2

450

70

S1

500

72

S1

500

95

S3

630

80

S1

900

120

S3

1250

140

S3

CA04020001Z-EN-INT

www.eaton.eu

DS4-340-11K-M
DS4-340-11K-MR
DM4-340-37K
DM4-340-45K
DS6-340-37K-MX
DS6-340-45K-MX
DS6-340-55K-MX
DS7-34…SX070N0-…
DS7-34…SX081N0-…
DS7-34…SX100N0-…
DS6-340-75K-MX
DS7-34…SX135N0-…
DM4-340-55K
DM4-340-75K
DS6-340-90K-MX
DS7-34…SX160N0-…
DM4-340-90K
DM4-340-110K
DM4-340-132K
DM4-340-160K
DS6-340-110K-MX
DS7-34…SX200N0-…
DM4-340-132K
DM4-340-160K
DM4-340-200K
DM4-340-250K
DM4-340-315K
DM4-340-400K
DM4-340-500K

JFHR2
053787_C_000
1422-30
UL recognized,
CSA certified
semiconductor
protection

170M1366
171974

170M3012
171976
170M2615
171975

Product Standards
UL File No.
UL Category
Control No.
North America
Certification
Suitable for

160

IEC/EN 60269-4;
UL 248-1; CSAC22.2 No. 248.14;
CE marking
E125085

170M3014
171977
170M4008
171978

170M4010
171979
170M4011
171980
170M5008
171984
170M4013
171981
170M4014
171982
170M6008
171985

170M4016
171983
170M6013
171986
170M6016
171987

Product Standards

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification
Suitable for

IEC/EN 60269-4;
UL 248-1; CE
marking
E125085
JFHR2
UL recognized
semiconductor
protection
IEC/EN 60269-4;
UL 248-1; CSAC22.2 No. 248.14;
CE marking
E125085
JFHR2
053787_C_000
1422-30
UL recognized,
CSA certified
semiconductor
protection

DS7 soft starters

113

Accessories

For use with

Part no.
Article no.

000, 00

170H1007
171988

Price
see price
list

Std. pack

Information relevant for export to North America

1 off

Product Standards

Fuse Bases
Dimensions
(W x H x D)
mm
145 x 43 x 50
205 x 88 x 80

S1*, S1, S2, S3

UL File No.
UL Category
Control No.
North America
Certification
Suitable for

170H3004
171989

IEC/EN 60269-1; UL 512; CE
marking
E14853
IZLT2
UL listed
DIN 43653 fuses

Overload relays
DS7-34…SX004…
DS7-34…SX007…
DS7-34…SX009…
DS7-34…SX012…
DS7-34…SX016…
DS7-34…SX024…

1 off

PKZM0-XDM12
283149

1 off

Product Standards
UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification
Suitable for
Max. Voltage Rating
Degree of Protection

UL 508; CSA-C22.2 No. 14;
IEC/EN 60947-4-1; IEC/EN
60947-5-1; CE marking
E29184
NKCR
12528
3211-03
UL listed, CSA certified
Branch circuits
600 V AC
IEC: IP20, UL/CSA Type: -

DS7

DS7-34…SX032…

ZB12-4
278438
ZB12-10
278440
ZB12-12
278441
ZB32-16
278452
ZB32-24
278453
ZB32-32
278454

Wiring set
For DOL Starter
DS7-34…SX004…
DS7-34…SX007…
DS7-34…SX009…
DS7-34…SX012…

Product Standards
UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

UL 508; CSA-C22.2 No. 14;
IEC60947-4-1; CE marking
E36332
NLRV
165628
3211-05
UL listed, CSA certified

Electric contact module
DS7-34…SX016…
DS7-34…SX024…
DS7-34…SX032…

PKZM0-XM32DE
239349

5 off

Product Standards

DS7-34…SX004…
DS7-34…SX007…
DS7-34…SX009…
DS7-34…SX012…

DILM12-XMCP/T
121770

1 off

Product Standards

UL 508; CSA-C22.2 No. 14;
IEC60947-4-1; CE marking
UL File No.
E36332
UL Category Control No.NLRV
CSA File No.
165628
CSA Class No.
3211-05
North America
Certification
UL listed, CSA certified

Motor feeder plug

North America
Certification

IEC/EN 60947-4-1; UL 508;
CSA-C22.2 No. 14-05; CE
marking
Request filed for UL and CSA

Busbar adapters
PKZM0, PKE + DS7...004N...
PKZM0, PKE + DS7...007N...
PKZM0, PKE + DS7...009N...
PKZM0, PKE + DS7...012N...
PKZM0, PKE + DS7...016N...
PKZM0, PKE + DS7...024N...
PKZM0, PKE + DS7...032N...

BBA0L-25
142526

1 off

BBA0L-32
142527

1 off

PKZM0, PKE + DS7...004N...
PKZM0, PKE + DS7...007N...
PKZM0, PKE + DS7...009N...
PKZM0, PKE + DS7...012N...
PKZM0, PKE + DS7...016N...
PKZM0, PKE + DS7...024N...
PKZM0, PKE + DS7...032N...

PKZM0-XC45L
142529

1 off

PKZM0-XC45L/2
142570

1 off

Top-hat rail adapter
45 mm wide adapter plate

CA04020001Z-EN-INT

www.eaton.eu

114

DS7 soft starters
Accessories

Std. pack

Notes

Information relevant for export to North
America

5 off

For the primary side of DS7
Suitable for 3 DS7 soft starters
Length 112 mm
For the primary side of DS7
Suitable for 4 DS7 soft starters
Length 157 mm
For the primary side of DS7
Suitable for 5 DS7 soft starters
Length 202 mm

Product StandardsIEC/EN 60947-4-1;
UL 508; CSA-C22.2
No. 14-05; CE
marking
UL File No.
E36332
UL Category
Control No.
NLRV
CSA File No.
012528
CSA Class No.
2411-03
North America
Certification
UL listed, CSA
certified

DILM12-XEK
240083

5 off

For three-phase commoning
link, protected against
accidental contact, Ue = 690 V,
Iu = 35 A.
Connection cross section:
Stranded 2.5…16 mm2
Flexible with ferrule
2.5…16 mm2
AWG14…8

Product StandardsIEC/EN 60947-4-1;
UL 508; CSA-C22.2
No. 14-05; CE
marking
UL File No.
E36332
UL Category
Control No.
NLRV
CSA File No.
012528
CSA Class No.
2411-03
North America
Certification
UL listed, CSA
certified

NZM1-XKSFA
100780

1 off

DS7-34…SX135…
DS7-34…SX160…
DS7-34…SX200…

NZM2-XKSFA
104640

1 off

DS7-34…SX135…
DS7-34…SX160…
DS7-34…SX200…

NZM2-XKSA
260038

1 off

Type contains parts for a
terminal located at top or
bottom for 3 pole circuitbreakers.
Enhancement of the busbar tag
shroud (simple protection
against contact with a finger).
Cannot be combined with NZMXSTK control circuit terminal.
Type contains parts for a
terminal located at top or
bottom for 3 pole circuitbreakers.
Enhancement of the busbar tag
shroud (simple protection
against contact with a finger).
Protection when reaching into
the cable connection area with
the connection of cables in the
box terminal.
With 2 conductors max cross
section 22 mm2 or AWG4.
Cannot be combined with NZMXSTK control circuit terminal.
Type contains parts for a
terminal located at top or
bottom for 3 pole circuitbreakers.
Busbar tag shroud where
cable lugs, busbars or tunnel
terminals are used.
When using insulated
conductor material to IP1X.

For use with

Part no.
Article no.

Price
see price
list

Three-phase commoning links
For the primary side of DS7
Suitable for 3 DS7 soft starters
Length 112 mm
protected against accidental contact, shortcircuit proof, Ue = 690 V, Iu = 35 A
can be extended by rotating by mounting
DS7-34…SX004…
DS7-34…SX007…
DS7-34…SX009…
DS7-34…SX012…

DILM12-XDSB0/3
240084
DILM12-XDSB0/4
240085
DILM12-XDSB0/5
240086

Incoming connection block
6

T2
L2

4

3

5

T1

T3
L3

2

1

L1

DS7-34…SX004…
DS7-34…SX007…
DS7-34…SX009…
DS7-34…SX012…

Terminal cover
Type contains parts for a terminal located at top
or bottom for 3 pole circuit-breakers.
Enhancement of the busbar tag shroud (simple
protection against contact with a finger).
Cannot be combined with NZM-XSTK control
circuit terminal.
knockout
DS7-34…SX041…
For box terminal
DS7-34…SX055…
DS7-34…SX070…
DS7-34…SX081…
DS7-34…SX100…

knockout

Product Standards

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification
Suitable for

CA04020001Z-EN-INT

www.eaton.eu

UL489; CSAC22.2 No. 5-09;
IEC60947, CE
marking
E31593
DIHS
22086
1432-01
UL listed, CSA
certified
Refer to main
component
information

DS7 soft starters

115

Accessories
Accessories

For use with

Part no.
Article no.

Price
see price
list

Std. pack

Notes

Information relevant for export to
North America

NZM2-XIPK
266773

1 off

NZM2-XIPA
266777

1 off

Type contains parts for a
terminal located at top or
bottom for 3 pole circuitbreakers.
Enhancement of the busbar
tag shroud to IP2X.
Protection when reaching into
the cable connection area
with the connection of cables
in the box terminal.
With 2 conductors max cross
section 25 mm2 or AWG4.
Cannot be combined with
NZM-XSTK control circuit
terminal.
Type contains parts for a
terminal located at top or
bottom for 3 pole circuitbreakers.
Enhancement of the busbar
tag shroud to IP2X.
When mounting NZM2-..(C)NA or NZM...-NA the
following applies:
with 2 conductors max cross
section 25 mm2 or AWG4.

DE6-MNT-NZM
107323

1 off

DS7-FAN-032
135553

1 off

DS7-FAN-100
169021

1 off

DS7-FAN-200
169022

1 off

PKE32-COM
168970

1 off

Typ enthält Teile für eine Schalterseite oben oder
unten für 3-polige Schalter.
Erhöhung des Berührungsschutzes auf IP2X.
For box terminal
NZM2, PN2, N(S)2

for cover NZM2-XKSA or
NZM2 or NZM2...(C)NA
und N(S)2...NA

NZM2, PN2, N(S)2

DS7

IP2X protection against contact with a
finger

Mounting kit
when using covers NZM1-XKSFA and
NZM2-XKSA
DS7-34xSX041N0-x
DS7-34xSX055N0-x
DS7-34xSX070N0-x
DS7-34xSX081N0-x
DS7-34xSX100N0-x
DS7-34xSX135N0-x
DS7-34xSX160N0-x
DS7-34xSX200N0-x

-

Device fans
Device fan for increasing the load cycle (more
starts per hour higher or longer-lasting starting
current)
DS7-34…SX004…
DS7-34…SX007…
DS7-34…SX009…
DS7-34…SX012…
DS7-34…SX016…
DS7-34…SX024…
DS7-34…SX032…
DS7-34…SX041…
DS7-34…SX055…
DS7-34…SX070…
DS7-34…SX081…
DS7-34…SX100…
DS7-34…SX135…
DS7-34…SX160…
DS7-34…SX200…

North America
Certification

Request filed for
UL and CSA

PKE communications cable
6-Pole
Prefabricated with two plugs
For connecting the PKE to DS7-SWD
DS7…SWD

CA04020001Z-EN-INT

www.eaton.eu

116

DS7 soft starters
General information on Engineering

Engineering
General information on Engineering

Generalized phase control of motor voltage
By means of generalized phase control, the soft starter adjusts the grid's voltage
(ULNsmoothly from an adjustable start value to 100 % of the rated value ULN .

In DS7 and S801+/S811+ series soft starters, generalized phase control is achieved
with anti-parallel thyristors that are bypassed for continuous operation by using
bypass contacts (TOR = Top Of Ramp) after the time for a time-triggered voltage
change (t-Start) has elapsed. The transition resistance of these bypass contacts is
considerably lower than the transition resistance of the power semiconductors.
This reduces the heat dissipation in the soft starter and extends the lifespan of the
power semiconductors.
As well as the time-controlled startup of a motor, the soft starter also enables a
time-controlled reduction of the motor voltage and thus a controlled stopping of the
motor.

U

ULN
TOR

U-Start

U-Start
t
t-Start

t
t-Start

ULN:Mains supply voltage
U-Start: start voltage
t-Start: Ramp time of the voltage change at start
TOR (Top of Ramp): Signals the end of the set "t-Start" ramp time
(output voltage U2 = Mains supply voltage ULN). The internal bypass contacts are
closed after this.
This voltage control enables the inrush current of a three-phase asynchronous
motor to be limited and its starting torque to be reduced. This enables a smooth and
jerk-free increase in torque, adjusted in line with the machine's load behavior. This
has a positive effect on the lifespan, operating behavior, and operating processes
of the mechanical equipment and prevents negative effects such as:
• Impacting of cog edges in the gearbox
• Pressure surge in pipe systems (water impact),
• Slipping of V belts or
• Jitter with conveyor systems.

CA04020001Z-EN-INT

www.eaton.eu

t-Stop

The output voltage of a soft starter determines the torque of the motor (M ~ U2).
Because of this, it is necessary to make sure that, when a machine starts up, the
selected U-Start start voltage is not too low and the t-Start ramp time for the linear
voltage change is set to be as short as possible.
Please note:
• Long ramp times (t-Start) will produce a soft startup behavior, but will also result
in a higher thermal load on the thyristors
• A high start voltage (U-Start) will produce a higher torque and a high starting
current
• Set the lowest possible start voltage and the shortest possible start ramps.
The following pages include application and setting configuration examples for DS7
soft starters.
If controlled deceleration is required, t-Stop must be set to a longer time than would
be necessary for the machine to coast freely based on the load. For the thyristors,
the controlled deceleration constitutes a load comparable to that produced during
startup. If, for example, the deceleration ramp is activated on a soft starter with a
maximum of 10 permissible starts per hour, the number of permissible starts will be
reduced to five per hour (plus five stops within that hour).

DS7 soft starters

117

General information on Engineering
Selection criteria

U, I, f

When different operating frequencies, run-up times and/or starting currents are
involved, the thermal capacity of the DS7 soft starter must be taken into account in
the design. This can be done by using the following diagrams or by calculating the
I2t values. These I2t values define the corresponding load capacity and overload
cycle and are defined in product standard IEC/EN 60947-4-2.

①

DS7-34…SX032…soft starter:
• 32A: AC-53a: 3-5: 75-10
• Rated operational current (Ie) 32 A
• Load cycle AC-53a
• 300% overcurrent for 5 seconds
• 75% duty factor with 10 starts per hour

③

The resulting I2t value is: (3 x 32 A)2 x 5 s = 46.080 A2s
The maximum I2t value of the connected motor load must be smaller:
(3 x 29 A)2 x 5 s = 37.845 A2s
Soft starter DS7-34…SX032… is the right choice for this application.

②

230 / 400 V ∆ / 
1.1 kW
1430 min-1

4.6 / 2.6 A
cos ϕ 0.81
50 Hz

If the motor had a higher inrush current, e.g., 5 times the starting current, a more
powerful soft starter would have to be selected:
• Motor inrush current: ILRP = 5 x 29 = 145 A, I2t value = (5 x 29 A)2 x 5 s = 105.125 A2s
• DS7-34…SX041…: 41A:
AC-53a: 3-5: 75-10
=> (3 x 41 A)2 x 5 s = 75.645 A2s
Soft starter DS7-34…SX041… cannot meet the required startup and load conditions
required in this case.

30 s
SX041 1/h
SX041 10/h
SX041 20/h

25 s

DS7

20 s
15 s
10 s
Soft starters ③ are selected based on the supply voltage of the corresponding grid
① (ULN) and the rated operational current of the assigned motor ②. The motor's
circuit configuration (Δ/Y) must be selected in such a way that it matches the supply
voltage. In addition, the soft starter's rated operational current (Ie) must be at least
equal to that of the motor.

5s
s
60 A

80 A
70 A

100 A
90 A

120 A
110 A

140 A
130 A

150 A

Additional selection criteria include:
• Ambient air temperature (rated value +40 °C)
• The number of starts per hour (< 10 starts, take stops into account)
• Load torque (quadratic, linear)
• Starting torque

DS7-34…SX055…:
55A: AC-53a: 3-5: 75-10
=> (3 x 55 A)2 x 5 s = 136.125 A2s
Soft starter DS7-34…SX055…, however, does meet the required startup and load
conditions.

Centrifugal pumps, centrifugal fans, simple and smooth-running conveyor belts and
traction drives, and circular saws and ribbon saws are some of the typical applications
for which soft starters are used. Reciprocating compressors, mixers, mills, crushers,
and lifting gear are instead categorized as heavy starting duty machines. In this case,
the soft starter must be oversized in terms of its overload capacity.

Note: As the following diagram shows, the DS7-34…SX055… unit can handle even
more demanding startup and load requirements, e.g., up to 20 starts per hour and
longer start-up times (up to 10 seconds).

30 s

In the case of applications that are typical for a soft starter, such as water pumps
(centrifugal pumps), and that feature comparable operational data (operating
frequency, run-up time, and/or inrush currents) a soft starter can be assigned
directly to the motor on the basis of the rated operational current.

25 s

Example:
• 15 kW Pump motor
• 400 V
• Rated operational current 29 A
• About three times the starting current (ILRP = 87 A),
• A maximum of 10 starts per hour
• 5-second start-up time
• ambient air temperature 40 °C.

15 s

SX055 1/h
SX055 10/h
SX055 20/h

20 s

10 s
5s
s
80 A

100 A

120 A

140 A

160 A

180 A

200 A

=> DS7-34…032… (Ie = 32 A)

30 s
10/h
1/h
20/h

25 s
20 s
15 s
10 s
5s
s
32 A

64 A

96 A

128 A

160 A

CA04020001Z-EN-INT

www.eaton.eu

118

DS7 soft starters
Design with different load cycles

Design with different load cycles

DS7-34...SX041N0-...

DS7-34...SX055N0-...

30 s

22K 1/h
22K 10/h

25 s

22K 20/h

20 s

30 s

15 s

10 s

10 s

5s

5s

60 A

70 A

80 A

90 A

100 A

110 A

120 A

130 A

140 A

s

150 A

DS7-34...SX070N0-...

37K 1/h
37K 10/h

25 s

37K 20/h

20 s

10 s

5s

5s

150 A

175 A

200 A

225 A

250 A

DS7-34...SX100N0-...

55K 1/h
55K 10/h

25 s

55K 20/h

20 s

s
100 A

200 A

45K 20/h

125 A

150 A 175 A 200 A 225 A 250 A

25 s
20 s
15 s

10 s

10 s

5s

5s

s
150 A 175 A 200 A 225 A 250 A 275 A 300 A 325 A 350 A

DS7-34...SX160N0-...

275 A 300 A

75K 1/h
75K 10/h
75K 20/h

s
125 A 175 A 225 A 275 A 325 A 375 A 425 A 475 A 525 A
150 A 200 A 250 A 300 A 350 A 400 A 450 A 500 A 550 A
DS7-34...SX200N0-...

30 s

90K 1/h
90K 10/h

25 s

90K 20/h

20 s

30 s
25 s
20 s

15 s

15 s

10 s

10 s

5s

5s

300 A

350 A

400 A

450 A

500 A

550 A

600 A

650 A

www.eaton.eu

110K 1/h
110K 10/h
110K 20/h

s
200 A
300 A
400 A
500 A
600 A
700 A
800 A
250 A
350 A
450 A
550 A
650 A
750 A

Additional diagrams for 4-32 A soft starters can be found in the manual for DS7 soft starters (MN03901001Z).

CA04020001Z-EN-INT

180 A

45K 1/h
45K 10/h

30 s

15 s

Note:

160 A

DS7-34...SX135N0-...

30 s

200 A

140 A

20 s

10 s

250 A

120 A

25 s

15 s

s
150 A

100 A

30 s

15 s

125 A

80 A

DS7-34...SX081N0-...

30 s

s
100 A

30K 20/h

20 s

15 s

s

30K 1/h
30K 10/h

25 s

DS7 soft starters

119

Potentiometer settings
Setting of potentiometer
Potentiometer settings

U

I

U

(R)
(AC11

(L)

250 V ∼
30 V H

0.2 A
0.7 A

1A
0.5 A

Imin

Umin

10 mA
100 mA

250 V ∼
5VH

U-Start

TOR

RUN

t-Start

t-Stop

TOR

t

RUN
13 14 23 24

13 14
(Top Of Ramp)
23 24

U-Start (%)

t-Start (s)
∼10

U-Start %
∼30

10

t-Stop (s)

t-Stop (s)
0
10

20

1

30

30

∼25

0

100

∼30
10

1

30

30

1

30

10

30

30

1

10

30

30

10

10

30

30

∼10

∼60
10

10

30

30

∼10

∼60
10

30

10

30

100

20

0

Bulk conveyor
Escalator

30

0

20

1

20

0

100

Tunnel fan
Axial fan
→ a Soft starter DS7 should
have a higher rating than the
assigned motor.

30

0

20

1

20

0

100

J→∞
Large gyrating mass
→ The DS7 soft starter's
rating should be higher than
the assigned motor output.

30

0

20

1

20

0

100

∼50

Fan general (building) with
belt drive

30

0

20

∼15

20

0

100

∼40
10

30

0

20

∼18

20

0

100

∼40

1

Centrifugal pump
10

30

10

30

∼20

20

∼15

20

0

100

∼30
10

Roller conveyers
10

30

∼10

30

0

20

1

20

0

100

∼40
10

Conveyor belt with loose belt
10

30

J→0
Low flywheel mass

30

∼30

20

∼20

20

DS7

t-Start (s)

Mixers
Agitators
→ a Soft starter DS7 should
have a higher rating than the
assigned motor.

30

CA04020001Z-EN-INT

www.eaton.eu

120

DS7 soft starters
Connection examples

Connection examples

Standard connection
up to 12 A
L1
L2
L3
PE

Q1

I> I> I>

5L3

3L2

1L1

F3

TOR

6T3

4T2

2T1

Q21

+ Us - A2 + A1

13

Q1
M
3~

M1
(+) Us
(–) Us 24 V AC/DC, 120/230 V AC

Standard connection
up to 32 A
L1
L2
L3
PE

Q1

I> I> I>

5L3

3L2

1L1

F3

TOR

RUN

6T3

4T2

2T1

Q21

- Us + Us

- A2 + A1

13

14

23

24

S3
Q1
M
3~

M1
(+) Us
(–) Us

CA04020001Z-EN-INT

www.eaton.eu

24 V AC/DC, 120/230 V AC

DS7 soft starters

121

Connection examples

Standard connection
41 - 200 A
With Emergency switching off function according to IEC/EN 60 204-1 and VDE 0113 Part 1
= EMERGENCY SWITCHING OFF
L1
L2
L3
PE

Q1
Q21
M1
F3

①
D2

U>

②

①
②
D1

3.13

= Cable and motor protection
(NZM (NZM1, NZM2)
= Soft starter DS7
= Motor
= superfast semiconductor fuse,
optional for type 2 coordination
(in addition to Q1)
Control circuit terminal
Undervoltage release with earlymake auxiliary contact

Q1
3.14

I>

I> I>

PE

5L3

3L2

1L1

F3

RUN

DS7

TOR

PE

6T3

4T2

2T1

Q21

- Us + Us - A2 EN + A1

13

14

23

24

S3

M1

M
3~

Q1
(+) Us

24 V AC/DC, 110/230 V AC

(–) Us

CA04020001Z-EN-INT

www.eaton.eu

122

DS7 soft starters

DS7 soft starters

Assigned switching and protective elements

123

Assigned switching and protective elements

Assigned switching and protective elements

Rated operational current1)

assigned
Motor output at
400 V
P
kW

480 V
P
HP

1.5
3
4
5.5
7.5
11
15
22
30
37
45
55
75
90
110

3.6
6.6
8.5
11.3
15.2
21.7
29.3
41
55
68
81
99
134
160
196

Soft starters
Ie
A_x

4
7
9
12
16
24
32
41
55
70
81
100
135
160
200

Soft starter function

Soft starter function with soft stop in case of overload

Mains contactor

Semiconductor contactor (optional, in addition to the protective devices for type 1 coordination, required for type 2 coordination)5)

Cable protection2)
Type “1” coordination

Cable protection2)
Type “1” coordination

optional4)

Fuses

Fuse holders

Number x Part no.

Number x Part no.

3 × 170M1359
3 × 170M1361
3 × 170M1362
3 × 170M1362
3 × 170M1364
3 × 170M1365
3 × 170M1366
3 × 170M1366
3 × 170M2615
3 × 170M4008
3 × 170M4008
3 × 170M4008
3 × 170M4011
3 × 170M5008
3 × 170M6008

3 x 170H1007
3 x 170H1007
3 x 170H1007
3 x 170H1007
3 x 170H1007
3 x 170H1007
3 x 170H1007
3 x 170H1007
3 x 170H1007
3 x 170H3004
3 x 170H3004
3 x 170H3004
3 x 170H3004
3 x 170H3004
3 x 170H3004

Soft starters for three-phase mains connection,
low operating frequency (5 s, 3 x Ie, 10 starts/h)
DS7-34xSX004N0-x
PKZM0-4 (+ CL-PKZ0)
DS7-34xSX007N0-x
PKZM0-10 (+ CL-PKZ0)
DS7-34xSX009N0-x
PKZM0-10 (+ CL-PKZ0)
DS7-34xSX012N0-x
PKZM0-12 (+ CL-PKZ0)
DS7-34xSX016N0-x
PKZM0-16 (+ CL-PKZ0)
DS7-34xSX024N0-x
PKZM0-25 (+ CL-PKZ0)
DS7-34xSX032N0-x
PKZM0-32 (+ CL-PKZ0)
DS7-34xSX041N0-x
NZMN1-M50 / PKZM4-50
DS7-34xSX055N0-x
NZMN1-M63 / PKZM4-58
DS7-34xSX070N0-x
NZMN1-M80
DS7-34xSX081N0-x
NZMN1-M100
DS7-34xSX100N0-x
NZMN1-M100
DS7-34xSX135N0-x
NZMN2-M160
DS7-34xSX160N0-x
NZMN2-M200
DS7-34xSX200N0-x
NZMN2-M200

PKM0-4 (+ CL-PKZ0)
PKM0-10 (+ CL-PKZ0)
PKM0-10 (+ CL-PKZ0)
PKM0-12 (+ CL-PKZ0)
PZM0-16 (+ CL-PKZ0)
PZM0-25 (+ CL-PKZ0)
PZM0-32 (+ CL-PKZ0)
NZMN1-M50 / PKZM4-50
NZMN1-M63 / PKZM4-58
NZMN1-M80
NZMN1-M100
NZMN1-M100
NZMN2-M160
NZMN2-M200
NZMN2-M200

overload relay3)

ZB12-4
ZB12-10
ZB12-10
ZB12-12
ZB32-16
ZB32-24
ZB32-32
ZB65-40+ZB65-XEZ
ZB65-57+ZB65-XEZ
ZB150-70/KK
ZB150-100/KK
ZB150-100/KK
ZB150-150/KK
Z5-160/FF250
Z5-220/FF250

DILM7
DILM9
DILM9
DILM12
DILM17
DILM25
DILM32
DILM50
DILM65
DILM80
DILM95
DILM115
DILM150
DILM185
DILM225

1)

Rated operational current based on the load cycle specified here.
Used to specify the circuit-breaker required for the specified load cycle. At different duty cycles (operating frequency, overcurrent, overcurrent
time, duty factor), this value changes and must then be adapted accordingly.
3) An external overload relay is required if the main contacts should not be disconnected in the event of an overload and a controlled soft stop is
desired instead.
4) A mains contactor is not required. Disconnection characteristics in accordance with VDE can only be ensured with the specified circuit-breaker.
5) The superfast semiconductor fuses protect the soft starter from short circuits on the motor side. This can not, however, prevent damage caused
by voltage peaks, for example through lightning strike.

DS7

Notes

2
3
5
7.5
10
15
20
25
30
40
50
60
75
100
125

Motor
Ie
A_x

Part no.
Soft starters
(device to be selected)

2)

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

124

DS7 soft starters

DS7 soft starters

Basic devices

125

Basic devices

Technical data
Basic devices

DS7…004…

DS7…007…

DS7…009…

DS7…012…

DS7…016…

DS7…024…

DS7…032…

DS7…041…

DS7…055…

DS7…070…

DS7…081…

DS7…100…

DS7…135…

DS7…160…

DS7…200…

25

24

30

42

General
Standards

Approvals
Approvals

Climatic proofing
DS7…-L

IEC/EN 60947-4-2
UL 508
CSA22.2-14
CE

IEC/EN 60947-4-2
UL 508
CSA22.2-14
CE

UL
CSA
C-Tick
UkrSEPRO
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-10
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-10
Cold test as per EN 60068-2-4

UL
CSA
C-Tick
UkrSEPRO
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-10
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-10
Cold test as per EN 60068-2-4
-5 - +40
up to 60 at 2% derating per Kelvin temperature rise
-40 - +40
up to 60 at 2% derating per Kelvin temperature rise
-25 - +60

Ambient temperature
ϑ

°C

ϑ

°C

-5 - +40
up to 60 at 2% derating per Kelvin temperature rise
-40 - +40
up to 60 at 2% derating per Kelvin temperature rise
-25 - +60

-40 - +60

m

-40 - +40
up to 60 at 2% derating per Kelvin temperature rise
0 - 1000 m, above that 1 % derating per 100 m , up to 2000 m
Vertical

Vertical

Protection type

IP20

IP20 (terminals IP00)

Integrated

-

Protection type IP40 can be achieved on all sides with covers from the NZM range.

Finger- and back-of-hand proof

Finger- and back-of-hand proof

DS7…-L
Storage
DS7…-L
Altitude
Mounting position

0 - 1000 m, above that 1 % derating per 100 m , up to 2000 m

DS7

Operation

Degree of protection

Protection against direct
contact
Rated insulation voltage

500

500

Overvoltage category/
pollution degree
Shock resistance

Ui

V AC

II/2

II/2

8 g/11 ms

8 g/11 ms

Vibration resistance to
EN 60721-3-2
Radio interference level
(IEC/EN 55011)
…342SX…

2M2

2M2

B

B

A

Heat dissipation

W

Weight

kg

0.2

A
0.35

0.45

0.6

0.8

1.1

1.5

7

10

13

18

…340SX…-N

0.35

0.4

1.8

1.8

3.7

…340SX…-L

0.44

0.49

0.44

1.8

3.7

…342SX…

0.4

0.45

0.4

1.8

3.7

…34DSX…

0.41

0.46

0.41

1.8

3.7

Main conducting paths
Rated operating voltage

Ue

V AC

200 - 480

200 - 480

Supply frequency

fLN

Hz

50/60

50/60

Ie

A

4

7

9

12

16

24

24

41

55

70

81

100

135

160

200

Rated operational current
Device (AC-53)
Assigned motor rating
(Standard connection, In-Line)
at 230 V, 50 Hz

P

kW

0.75

1.5

2.2

3

4

5.5

5.5

11

15

15

22

30

30

45

55

at 400 V, 50 Hz

P

kW

1.5

3

4

5.5

7.5

11

11

22

30

37

45

55

75

90

110

at 200 V, 60 Hz

P

HP

0.75

2

2

3

5

7.5

7.5

10

15

20

25

30

40

50

60

at 230 V, 60 Hz

P

HP

1

2

3

3

5

7.5

7.5

15

20

25

30

30

50

60

75

at 480 V, 60 Hz

P

HP

2

5

5

10

10

15

15

30

40

50

60

75

100

125

150

4 A: AC-53a:
3 - 5: 75 - 10
✓

7 A: AC-53a:
3 - 5: 75 - 10
✓

9 A: AC-53a:
3 - 5: 75 - 10
✓

12 A: AC-53a:
3 - 5: 75 - 10
✓

16 A: AC-53a:
3 - 5: 75 - 10
✓

24 A: AC-53a:
3 - 5: 75 - 10
✓

32 A: AC-53a:
3 - 5: 75 - 10
✓

41 A: AC-53a:
3 - 5: 75 - 10
✓

55 A: AC-53a:
3 - 5: 75 - 10
✓

70 A: AC-53a:
3 - 5: 75 - 10
✓

81 A: AC-53a:
3 - 5: 75 - 10
✓

100 A: AC-53a:
3 - 5: 75 - 10
✓

135 A: AC-53a:
3 - 5: 75 - 10
✓

160 A: AC-53a:
3 - 5: 75 - 10
✓

200 A: AC-53a:
3 - 5: 75 - 10
✓

Overload cycle to IEC/EN
60947-4-2
AC-53a (without bypass)
Internal bypass contacts

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

126

DS7 soft starters

DS7 soft starters

Basic devices

127

Basic devices

DS7…004…

DS7…007…

DS7…009…

DS7…012…

DS7…016…

DS7…024…

DS7…032…

DS7…041…

DS7…055…

DS7…070…

DS7…081…

DS7…100…

DS7…135…

DS7…160…

DS7…200…

PKM0-4
(+ CL-PKZ0)
3 x 170M1359

PKM0-10
(+ CL-PKZ0)
3 x 170M1361

PKM0-10
(+ CL-PKZ0)
3 x 170M1362

PKM0-12
(+ CL-PKZ0)
3 x 170M1362

PKM0-16
(+ CL-PKZ0)
3 x 170M1364

PKM0-25
(+ CL-PKZ0)
3 x 170M1365

PKM0-32
(+ CL-PKZ0)
3 x 170M1366

NZMN1-M50/
PKZM4-49
3 x 170M3012

NZMN1-M63/
PKZM4-57
3 x 170M2615

NZMN1-M80

NZMN1-M100

NZMN1-M100

NZMN2-M160

NZMN2-M200

NZMN2-M200

3 x 170M4008

3 x 170M4008

3 x 170M4008

3 x 170M4010

3 x 170M5008

3 x 170M6008

3 x 170H1007

3 x 170H1007

3 x 170H1007

3 x 170H1007

3 x 170H1007

3 x 170H1007

3 x 170H1007

3 x 170H3004

3 x 170H1007

3 x 170H3004

3 x 170H3004

3 x 170H3004

3 x 170H3004

3 x 170H3004

3 x 170H3004

Short-circuit rating
Type “1” coordination
Type “1” coordination
Type „2“ coordination
short-circuit rating
(additional with the
fuses for coordination
type „1“)
Fuse base (number x part no.)
Terminal capacities
Cable lengths
Solid

mm2

Flexible with ferrule

mm2

Stranded

mm2

1 x (0.75 - 4)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
-

1 x (0.75 - 16)
2 x (0.75 - 10)
1 x (0.75 - 16)
2 x (0.75 - 10)
1 x 16

1 x (25 - 70)
2 x (6 - 25)
-

1 x (4 - 185)
2 x (4 - 70)
-

18 - 6

1 x (25 - 70)
2 x (6 - 25)
1 x (12 - 2/0)

1 x (4 - 185)
2 x (4 - 70)
1 x (12 - 350 kcmil)
2 x (12 - 00)

Solid or stranded

AWG

18 - 10

Copper band

MM

-

-

2 x 9 x 0.89 x 9 x 0.8

Tightening torque

Nm

1.2

3.2

6 (≤ 10 mm²); 9 (> 10 mm²)

5 (≤ 10 mm²); 14 (> 10 mm²)

Screwdriver (PZ: Pozidriv)

mm

PZ2; 1 x 6 mm

PZ2; 1 x 6 mm

PZ2; 1 x 6 mm

PZ2; 1 x 6 mm

Solid

mm2

Flexible with ferrule

mm2

Stranded

mm2

1 x (0.75 - 4)
2 x (0.75 - 2.5)
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
-

Solid or stranded

AWG

18 - 10

Tightening torque

Nm

1.2

1 x (0.5 - 2.5)
2 x (0.5 - 1.0)
1 x (0.5 - 1.5)
2 x (0.5 - 0.75)
1 x (0.5 - 1.5)
2 x (0.5 - 1.0)
1 x (21 - 14)
2 x (21 - 18)
1.2

1 x (0.5 - 2.5)
2 x (0.5 - 1.0)
1 x (0.5 - 1.5)
2 x (0.5 - 0.75)
1 x (0.5 - 1.5)
2 x (0.5 - 1.0)
1 x (21 - 14)
2 x (21 - 18)
0.4

1 x (0.5 - 2.5)
2 x (0.5 - 1.0)
1 x (0.5 - 1.5)
2 x (0.5 - 0.75)
1 x (0.5 - 1.5)
2 x (0.5 - 1.0)
1 x (21 - 14)
2 x (21 - 18)
0.4

Screwdriver

mm

0,8 x 5,5
1x6

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

DS7

Control cables

Control circuit
Regulator supply
Notes
External supply voltage
Voltage

Us

V

…340SX…

24 V AC/DC +10 %/- 15 %

24 V AC/DC +10 %/- 15 %

…342SX…

110 V AC -15 % - 230 V AC +10 %

110 V AC -15 % - 230 V AC +10 %

…34DSX…

24 V DC +10 %/- 15 %

24 V DC +10 %/- 15 %

Current consumption

Ie

mA

50

50

IPeak

mA/ms

-

600/50

…340SX…-N

24 V DC +10 %/- 15 %

24 V DC +10 %/- 15 %

…340SX…-L

24 V DC +10 %/- 15 %

24 V DC +10 %/- 15 %

…34DSX…

24 V DC +10 %/- 15 % oder über SWD

24 V DC +10 %/- 15 % oder über SWD

…340SX…-N

24 V AC +10 %/- 15 %

24 V AC +10 %/- 15 %

…342SX…-N

110 V AC - 15 % - 230 V AC +10 %

110 V AC - 15 % - 230 V AC +10 %

1.6

1.6

4

4

17.3 - 27

17.3 - 27

…340SX…

17.3 - 27

17.3 - 27

…342SX…

108 - 253

108 - 253

Current consumption
at peak performance
(close bypass) at 24 V DC
Digital inputs
Control voltage
DC-operated

V DC

AC operated

V AC

Current consumption 24 V
External 24 V

mA

Current consumption 230 V
230 V AC

mA

…342SX…
Pick-up voltage
DC-operated

V DC

AC operated

V AC

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

128

DS7 soft starters

DS7 soft starters

Basic devices

129

Basic devices

DS7…004…

DS7…007…

DS7…009…

DS7…012…

DS7…016…

DS7…024…

DS7…032…

DS7…041…

DS7…055…

DS7…070…

DS7…081…

DS7…100…

DS7…135…

DS7…160…

DS7…200…

Drop-out voltage
DC operated

V DC

AC operated

V AC

0-3

0-3

…340SX…

0-3

0-3

…342SX…

0 - 15

0 - 15

Pick-up time
DC operated

ms

250

250

AC operated

ms

250

250

DC operated

ms

350

350

AC operated

ms

350

350

Drop-out time

Relay outputs
1 (TOR)

2 (TOR, Ready)

2 (TOR, Ready)

Voltage range

Number
V AC

= Us

250

250

AC-11 current range

A

1 A, AC-11

1 A, AC-11

1 A, AC-11

Acceleration

s

1 - 30

1 - 30

Deceleration

s

0 - 30

0 - 30

%

30 - 100

30 - 100

(0 - 8) x Ie

(0 - 8) x Ie

Fields of application

Soft starting of three-phase asynchronous motors

Soft starting of three-phase asynchronous motors

3-phase motors

✓

✓

Fast switching (semiconductor
contactor)
Soft start function

- (minimum ramp time 1s)

- (minimum ramp time 1s)

✓

✓

Reversing starter

External solution required

External solution required

Suppression of closing
transients
Current limitation

✓

✓

Soft start function
Ramp times

Start pedestal
…34DSX…(+PKE)

DS7

Current limitation
Fields of application

Functions

…34DSX…

✓, with PKE

✓, with PKE

Overload monitoring

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Underload monitoring

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Thermistor input

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Fault memory

Faults

…34DSX…

8

Pre-programmed parameter
sets
Suppression of DC
components for motors
Potential isolation between
power and control sections
Built-in interfaces
…34DSX…

CA04020001Z-EN-INT

www.eaton.eu

-

8
-

✓

✓

✓

✓

SmartWire-DT

SmartWire-DT

CA04020001Z-EN-INT

www.eaton.eu

130

DS7 soft starters
Soft starters

Dimensions
Soft starters

DS7-340SX004N0-N

DS7-342SX004N0-N

DS7-340SX041N0-N

DS7-342SX041N0-N

DS7-34DSX041N0-D

DS7-340SX007N0-N

DS7-342SX007N0-N

DS7-340SX055N0-N

DS7-342SX055N0-N

DS7-34DSX055N0-D

DS7-340SX009N0-N

DS7-342SX009N0-N

DS7-340SX070N0-N

DS7-342SX070N0-N

DS7-34DSX070N0-D

DS7-340SX012N0-N

DS7-342SX012N0-N

DS7-340SX081N0-N

DS7-342SX081N0-N

DS7-34DSX081N0-D

DS7-340SX100N0-N

DS7-342SX100N0-N

DS7-34DSX100N0-D

DS7-34DSX004N0-D

DS7-34DSX009N0-D

DS7-34DSX007N0-D

DS7-34DSX012N0-D

175 mm (6.89”)

45 mm (1.77”)

① 156 mm (6.14”)

161 mm (6.34”)

95 mm (3.74”)

4 x M4

 PE

129 mm (5.08”)

125 mm (4.92”)

30 mm

(1.18”) (1.18”)
22.5 mm
(0.89”)

40 mm (1.58”)

35 mm
(1.38”)

122 mm (4.80”)

130 mm (5.12”)

30 mm

35 mm (1.38”)

125 mm (4.92”)

122 mm (4.80”)

130 mm (5.12”)

 PE 22.5 mm (0.89”)

35 mm
(1.38”)

4 x M4

①

139 mm (5.47”)

93 mm (3.66”)

① DS7-...-D

95 mm (3.74”)
103 mm (4.05”)

45 mm (1.77”)

DS7-340SX016N0-N

DS7-342SX016N0-N

DS7-340SX135N0-N

DS7-342SX135N0-N

DS7-34DSX135N0-D

DS7-340SX024N0-N

DS7-342SX024N0-N

DS7-340SX160N0-N

DS7-342SX160N0-N

DS7-34DSX160N0-D

DS7-340SX032N0-N

DS7-342SX032N0-N

DS7-340SX200N0-N

DS7-342SX200N0-N

DS7-34DSX200N0-D
① 195 mm (7.68”)

118 mm (4.65”)
45 mm (1.77”)

158 mm (6.22”)
200 mm (7.87”)
215 mm (8.46”)

 PE

40 mm (1.58”)

4 x M4
35 mm
(1.38”)

(0.59”)

140 mm (5.51”)

150 mm (5.90”)

35 mm
35 mm
(1.38”)
(1.38”)
15 mm

①

DS7-34DSX016N0-D
DS7-34DSX024N0-D
DS7-34DSX032N0-D

2 x M4
35 mm
(1.38”)

CA04020001Z-EN-INT

52.5 mm (2.07”)
178 mm (7.01”)

① DS7-...-D

118 mm (4.65”)
45 mm (1.77”)

15 mm (0.59”)

108 mm (4.25”)

140 mm (5.51”)

150 mm (5.90”)

 PE

126 mm (4.96”)

www.eaton.eu

DS7 soft starters

131

Superfast semiconductor fuses, Fuse Bases
Superfast semiconductor fuses, Fuse Bases

Device fans

238
69

259

192

DS7-FAN-200

211

DS7-FAN-100

17

90

50
17

83

70

105

Superfast semiconductor fuses

a1

a1
mm (inch)
20 (0.79)
28 (1.1)

a2
mm (inch)
8 (0.31)
10 (0.39)

Size
(size)
000
00

a
mm (inch)
104 (4.09)
108 (4.25)
108 (4.25)
109 (4.29)

a1
mm (inch)
78 (3.07)
78 (3.07)
78 (3.07)
78 (3.07)

a2
mm (inch)
50 (1.97)
50 (1.97)
50 (1.97)
51 (2.01)

DS7

55 mm (2.17")
2 mm
(0.08")

a2

a
mm (inch)
40 (1.57)
51 (2.01)

100 mm (3.9")

80 mm (3.15")

a2

Sizes 000, 00

a

11 mm (0.43")

11 mm (0.43")
a2

b

b1

Sizes S1*, S1, S2, S3

6 mm (0.24")
b

b
mm (inch)
45 (1.77)
53 (2.09)
61 (2.40)
76 (2.99)

b1
mm (inch)
22 (0.87)
25 (0.98)
25 (0.98)
30 (1.18)

Size
(size)
S1*
S1
S2
S3

a1
a

Fuse Bases
170H3004

170H1007
M10

M8

M10

40 mm (1.57)
85 mm (3.35")

126 mm (4.9")

80 mm (3.15")

146 mm (5.75")

25 mm (0.98")

80 mm (3.15")

205 mm (8.07")

4 x ⌀ 7 mm
(4 x ⌀ 0.3")

150 mm (5.91")

50 mm (1.97)

9 mm (0.35")

M8

64 mm (2.52")
77 mm (3.03")

25 mm (0.98")
43 mm (1.69")

40.5 mm (1.59")
50.5 mm (1.99")

CA04020001Z-EN-INT

www.eaton.eu

S801+/S811+ Soft Starters – Powerful
Performance in a Small Package
The incredible performance of our two new S801+ and S811+ soft starter series is
shaped by the expanded functionality that we have integrated into our tried-and-true
series of soft starters. With only five sizes and rated operational currents of 37 A to
1,000 A for line voltages of 200 V to 690 V, the S801+ and S811+ are two of the
smallest, most compact soft starters in the world.
These three-phase controlled soft starters, which feature an internal bypass and extensive monitoring and protection mechanisms, guarantee not only soft motor start-ups, but
also the safe and reliable continuous operation of three-phase motors even in applications involving high load torques. In addition, these soft starters can be connected with
a standard in-line configuration or with an inside-the-delta (also called "six wire connection") configuration as needed.
S801+ soft starters were designed with standard applications in mind and owe an
important part of their appeal to their ease of use, while the devices in the S811+
series are characterized by a digital control and display unit that provides access to
extended functions for sophisticated applications.

Soft starter S801+, S811+

133

System overview
Soft starter S801+, S811+

134

Description
Soft starter S801+, S811+

135

Key to type references, UL/CSA
Soft starter S801+, S811+

136

Ordering
Soft starter S801+, S811+

137

Accessories

139

Engineering
Connection examples S811+...N3S

141

Technical data
Soft starter S801+, S811+

142

Dimensions
150

S801+, S811+

Soft starter S801+, S811+

CA04020001Z-EN-INT

www.eaton.eu

134

Soft starter S801+, S811+

System overview

1

2

3

1

S801+ / S811+
→ page 137

Fuse base for superfast semiconductor fuses

2

→ page 111

Superfast semiconductor fuses
→ page 112

CA04020001Z-EN-INT

www.eaton.eu

3

Soft starter S801+, S811+

135

Description

S811+ series soft starters provide all the features and characteristics
of S801+ soft starters, plus expanded functionality and an operating unit
(DIM = digital interface module).

ONLN SS OXFDO1 H STOP

S801+ soft starters are three-phase controlled and come with internal bypass
contacts for continuous operation. With them, motors can be connected with
a standard in-line circuit or inside the delta circuit (inside-the-delta circuit,
√3 circuit). Using an inside-the-delta circuit will reduce the current flowing
through the soft starter by approximately 42%. This makes it possible, for
example, to start and run a motor with a rated operational current of 100 A
using a 58-A soft starter. In addition, their comprehensive protection and
monitoring features enable S801+ soft starters to ensure that three-phase
motors with rated operational currents of 11 A to 1000 A will have soft startups
and safe and reliable continuous operation at mains voltages of 200 V to 600 V
– up to 690 V in the case of S811+ soft starters. Accordingly, for instance, their
controlled coasting (soft stop control) and torque monitoring features can be
used to prevent water impact in pumps and to reduce the mechanical loads on
pump systems significantly.

Essential features S801+ / S811+
•
•
•
•
•

•
•
•
•
•
•
•
•

Rated operational current: 37 - 1000 A
Parameterizable overload settings: 31–100%
Adjustable overload classes: class 5, 10, 20, 30
Base setting: 15 s start ramp, 4 starts per hour, 300% starting current at 40 °C
ambient temperature
Allocated motor outputs for in-line connection:
– 7.5 - 277 kW (3~ 230 V)
– 18.5 - 525 kW (3~ 400 V)
– 30 - 900 kW (3~ 690 V)
Ambient air temperature: -30 °C to +50 °C
any required mounting position
Degree of protection with compact design (IP20 optional)
5 compact designs
Adjustable torque control
Adjustable kick start
Efficient use of power achieved with internal bypass contacts during
continuous operation
24-V control voltage:
– External supply required
– 1 A continuous current
– 10 A starting current (peak value for 15 ms)

Monitoring
PREV

NEXT

ENTER

S801+, S811+

S801+ series soft starters are an innovative addition that further enhances
their tried-and-true predecessors. They are designed to guarantee reliable
operation even under harsh and challenging ambient conditions. In addition,
the series makes a compelling case as a result of its ease of use and is the
perfect choice for standard applications such as pumps, fans, compressors,
and conveyor belts.

Important operating unit characteristics (S811+)
•
•
•
•
•
•
•

Language-neutral LCD display with backlight
Easy to use and configure with function keys
System parameter configuration
Diagnostic and monitoring options
Reading display (e.g., L1, L2, L3 phase currents)
Error display
Offset placement (mounted on door), connection via plug-in patch cord with
RJ45 plug
• Front IP54

S811+ specific characteristics
• Mains voltage up to 690 V?
• Special pump control algorithm with prolonged soft stop ramp

S801+ specific characteristics
• Microswitches and potentiometers make it easy to configure these soft
starters

CA04020001Z-EN-INT

www.eaton.eu

136

Soft starter S801+, S811+

Key to type references

S 801+ N 66 N 3 S
S = soft starters

S = Standard version

Version

Number of poles

801+ = with adjustable elements
811+ = with keypad

3 = Three-pole device
Fitted with

Frame size

N = Basic device (S801+/S811+)
P = Pump control (S811+)
V = 690 V rated (S811+)

N = 65 mm
R = 110 mm
T = 200 mm
U = 200 mm
V = 290 mm
Rated operational current Ie
37 = 37 A
66 = 66 A
10 = 105 A
13 = 135 A
18 = 180 A
24 = 240 A
30 = 304 A
36 = 361 A
42 = 420 A
50 = 500 A
65 = 650 A
72 = 720 A
85 = 850 A
10 = 1000 A

UL/CSA
Information relevant for export to North America

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Conditions of Acceptability
Suitable for
Max. Voltage Rating
Degree of Protection

S801+N…, S801+R…, S801+T… (600 V)
S811+N…, S811+R…, S811+T… (600 V)
IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking
E202571
NMFT
LR 353
3211-06, 2411-01
UL Listed, CSA Certified
None
Branch Circuits, not as BCPD
600 Vac
IP20 with kit

Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Conditions of Acceptability
Suitable for
Max. Voltage Rating
Degree of Protection

S801+V…, 1000 A (600 V)
S811+V…, 1000 A (600 V)
IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking
E202571
NMFT2
LR 353
3211-06
UL Recognized, CSA Certified
98-115 CFM fan and 4" x 4" vent req'd
Branch Circuits, not as BCPD
600 Vac
IP20 with kit

CA04020001Z-EN-INT

www.eaton.eu

S801+U…, S801+V... bis 850 A (600 V)
S811+U…, S811+V... bis 850 A (600 V)
IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking
E202571
NMFT
LR 353
3211-06
UL Listed, CSA Certified
None
Branch Circuits, not as BCPD
600 Vac
IP20 with kit

S811+…V3S (690 V)
IEC/EN 60947-4-2; UL 508; CE marking
E202571
NMFT

UL Listed
None
Branch Circuits, not as BCPD
690 Vac
IP20 with kit

Soft starter S801+, S811+

137

Basic devices

Ordering
Basic devices

Frame size

Rated operational current

Assigned motor rating

Device (AC-53)

at 400 V, 50 Hz

at 480 V, 60 Hz

Ie

P

P

A

kW

HP

Part no.

Article no.

Price
see price list

Std. pack

Soft starters

R
T

U
V

25

S801+N37N3S

169852

66

30

50

S801+N66N3S

169853

105

55

75

S801+R10N3S

169854

135

75

100

S801+R13N3S

169855

180

90

150

S801+T18N3S

169856

240

132

200

S801+T24N3S

169857

304

160

250

S801+T30N3S

169858

361

200

300

S801+U36N3S

169859

420

200

350

S801+U42N3S

169860

361

200

300

S801+V36N3S

169863

420

200

350

S801+V42N3S

169864

500

250

400

S801+V50N3S

169865

650

315

500

S801+V65N3S

169866

720

400

600

S801+V72N3S

169867

850

450

600

S801+V85N3S

169868

1000

560

750

S801+V10N3S

169862

Soft starter for three-phase loads, with control unit
N
37
18.5
R
T

U
V

25

S811+N37N3S

168976

66

30

50

S811+N66N3S

168978

105

55

75

S811+R10N3S

168980

135

75

100

S811+R13N3S

168982

180

90

150

S811+T18N3S

168984

240

132

200

S811+T24N3S

168987

304

160

250

S811+T30N3S

168990

361

200

300

S811+U36N3S

169869

420

200

350

S811+U42N3S

169870

361

200

300

S811+V36N3S

168993

420

200

350

S811+V42N3S

168996

500

250

400

S811+V50N3S

168999

650

315

500

S811+V65N3S

169002

720

400

600

S811+V72N3S

169005

850

450

600

S811+V85N3S

169008

1000

560

750

S811+V10N3S

169011

Soft starter for three-phase loads, with control unit and pump algorithm
N
37
18.5
R
T

U
V

Notes

25

S811+N37P3S

168977

66

30

50

S811+N66P3S

168979

105

55

75

S811+R10P3S

168981

135

75

100

S811+R13P3S

168983

180

90

150

S811+T18P3S

168985

240

132

200

S811+T24P3S

168988

304

160

250

S811+T30P3S

168991

361

200

300

S811+U36P3S

169872

420

200

350

S811+U42P3S

169873

361

200

300

S811+V36P3S

168994

420

200

350

S811+V42P3S

168997

500

250

400

S811+V50P3S

169000

650

315

500

S811+V65P3S

169003

720

400

600

S811+V72P3S

169006

850

450

600

S811+V85P3S

169009

1000

560

750

S811+V10P3S

169012

1 off

1 off

S801+, S811+

Mains supply voltage (50/60 Hz) ULN: 200 - 600 V AC
Supply voltage Us: 24 V DC
Control voltage UC: 24 V DC, With internal bypass contacts
Soft starters for three-phase loads
N
37
18.5

1 off

Information relevant for export to North America → Page 136

CA04020001Z-EN-INT

www.eaton.eu

138

Soft starter S801+, S811+
Basic devices

Frame size

Rated
operational
current
Device (AC-53)

Assigned motor rating

at 400 V, 50 Hz

at 690 V, 50 Hz

at 480 V, 60 Hz

Ie

P

P

P

A

kW

kW

HP

Part no.

Article no.

Price
see price list

Std. pack

Soft starters
Mains supply voltage (50/60 Hz) ULN: 200 - 690 V AC
Supply voltage Us: 24 V DC
Control voltage UC: 24 V DC
With internal bypass contacts
Soft starter for three-phase loads, with control unit and pump algorithm, for 690-V grids
T
180
90
160
150
240
V

S811+T18V3S

168986

132

200

200

S811+T24V3S

168989

304

160

250

250

S811+T30V3S

168992

361

200

315

300

S811+V36V3S

168995

420

200

400

350

S811+V42V3S

168998

500

250

500

400

S811+V50V3S

169001

650

315

630

500

S811+V65V3S

169004

720

400

630

600

S811+V72V3S

169007

850

450

710

600

S811+V85V3S

169010

Notes
Sizes S801+, S811+

L1

1

L2

3

L3

L1 1
5

N

L2 3

L3 5

R

T

Information relevant for export to North America → Page 136

CA04020001Z-EN-INT

www.eaton.eu

U

V

1 off

Soft starter S801+, S811+

139

Accessories
Accessories

Description

For use with

Part no.
Article no.

S801+

EMA71
144346
EMA91
144570

Price
see price
list

Std. pack

Information relevant for export to North America

1 off

Product Standards

Control unit
With adjusting elements (potentiometer,
microswitch)
With illuminated LCD display
With control buttons and function keys
Front IP54
RJ45 plug, 8-pin

S811+

IEC/EN 60947-4-2; UL 508;
CSA C22.2 No. 14; CE
marking
UL File No.
E202571
CSA File No.
LR 353
Conditions of Acceptability UL unlisted component, CSA
Investigated Component

Cover
Protection for installation space in S811+ if the control unit is set up
externally.
S811+
EMA68
144556

1 off

Mounting frame
For mounting the EMA91 control unit externally with surface
mounting (e.g., installation in control panel door).
EMA91

EMA69A
144557

1 off

Product Standards

EMA69B
144558
EMA69C
144559
EMA69D
144560

1 off

Product Standards

S801+, S811+

EMA75
144561

1 off

S801+, S811+,
Baugröße N
S801+, S811+,
Baugröße R
S801+, S811+,
Baugrößen T und U
S801+, S811+,
Baugröße V

SS-IP20-N
171990
SS-IP20-R
171991
SS-IP20-TU
171992
SS-IP20-V
158650

1 off

IEC/EN 60947-4-2; UL 508;
CSA C22.2 No. 14; CE
marking
UL File No.
E202571
UL Category Control No.
NMFT2
CSA File No.
LR 353
CSA Class No.
3211-06
North America Certification UL listed, CSA certified

Connection cable
EMA91
EMA91
EMA91

IEC/EN 60947-4-2; UL 508;
CSA C22.2 No. 14; CE
marking
UL File No.
E202571
UL Category Control No.
NMFT2
CSA File No.
LR 353
CSA Class No.
3211-06
North America Certification UL listed, CSA certified

Control terminal strip
-

IP20 Kits
-

CA04020001Z-EN-INT

www.eaton.eu

S801+, S811+

Connection cable with RJ45 plugs, 8 pole

140

Soft starter S801+, S811+
Accessories

Description

For use with

Part no.
Article no.

S801+, S811+,
Baugrößen T und U

EML22
127661

Price
see price
list

Std. pack

Information relevant for export to North America

1 off

Product Standards
UL File No.
UL Category Control No.
CSA File No.
CSA Class No.
North America Certification
Conditions of Acceptability

Terminal blocks
Tools with dimensions in inches required
Terminal capacities
2 x 4-1/0MCM, 2 x 25-50 mm²

EML23
127662
EML24
127663
EML25
127664
EML26
127665

4/0-500 MCM, 120-150 mm²
2 x 4/0-500 MCM, 2 x 120-150 mm²
2 x 2/0-300 MCM, 2 x 70-150 mm²
2/0-300 MCM, 70-150 mm²
4/0-500 MCM, 120-150 mm²

S801+, S811+,
Baugröße V

EML27
144549
EML28
127666
EML30
127667
EML32
127668
EML33
127669

S801+, S811+, bis
600 V

EMS39
127671

1 off

S811+, bis 690 V

EMS41
127672

1 off

S801+, S811+

C441V
172306

1 off

2 x 4/0-500 MCM, 2 x 120-150 mm²
4 x 4/0-500 MCM, 4 x 120-150 mm²
6 x 4/0-500 MCM, 6 x 120-150 mm²
4 x 2/0-300 MCM, 4 x 70-150 mm²

Max. Voltage Rating

UL 1059
E60693
NMFT
LR 353
6223-02
UL listed, CSA certified
10A min, Use group C or D,
30 to 12 AWG solid/stranded
300 Vac

Product Standards
UL File No.
UL Category Control No.
CSA File No.
CSA Class No.
North America Certification

UL508, CSA C22.2 No. 65
E202571
NMFT
LR 353
6223-02
UL listed, CSA certified

Product Standards
UL File No.
CSA File No.
Conditions of Acceptability

UL 508; CSA C22.2 No. 14
E202571
LR 353
UL and CSA Investigated
Component
1000 Vac 3 ph

TVSS
SMD metal-oxide varistors (MOVs) with
connection cables for the grid and motor
connection sides

Max. Voltage Rating

EtherNet/IP - Modbus/TCP adapter
-

Product Standards
UL File No.
UL Category Control No.
CSA File No.
CSA Class No.
Max. Voltage Rating

CA04020001Z-EN-INT

www.eaton.eu

IEC/EN 60947-4-1; UL 508;
CSA C22.2 No. 14; CE
marking
E1230
NKCR
LR 353
3211-03
240 Vac (auxiliary contacts)

Soft starter S801+, S811+

141

Connection examples

Engineering
Connection examples

Connection examples for S811+…N3S
Standard connection (in-line connection)

4T2

6T3

Fault/Reset

2T1

Hand/Auto

Q21

Jog

5L3

Start

3L2

L3

Enable

1L1

L2

(+) Us

L1

(–) Us

PE

–

+

P

1

2

3

4

Ready/Fault

TOR

13

14

95

96

98

a
M
3~

M1
(+) Us
(–) Us

24 V DC

b

① Snap-on ferrite core, included as standard
② External control voltage (24 VDC) required, IS 100 mA, IPeak = 10 A for 15 ms when bypass contacts are switched

Delta circuit (inside-the-delta circuit)

Q1

S801+, S811+

L1
L2
L3
PE

F1
I>

I> I>

Q11
F2

U1

V1

M
3~
U2

V2

Fault/Reset

6T3

Hand/Auto

4T2

Jog

2T1

Start

Q21

Enable

5L3

(+) Us

3L2

(–) Us

1L1

–

+

P

1

2

3

4

TOR

13

14

Ready/Fault

95

96

98

①

W1

M1
(+) Us
W2

(–) Us

24 V DC

②

① Snap-on ferrite core, included as standard
② External control voltage (24 VDC) required, IS 100 mA, IPeak = 10 A for 15 ms when bypass contacts are switched
Short-circuit and cable protection: Q1 circuit-breakers or F1 fuses.

CA04020001Z-EN-INT

www.eaton.eu

142

Soft starter S801+, S811+

Soft starter S801+, S811+

Basic devices

143

Basic devices

Technical data
Basic devices

S8x1+N37…

S8x1+N66…

S8x1+R10…

S8x1+R13…

S8x1+T18…

S8x1+T24…

S8x1+T30…

S8x1+U36…

S8x1+U42…

IEC/EN 60947-4-2
UL 508
CSA22.2-14-1995
GB14048
CE

IEC/EN 60947-4-2
UL 508
CSA22.2-14-1995
GB14048
CE

CE

CE

CE

CE

UL
CSA
C-Tick
CCC
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-10

UL
CSA
C-Tick
CCC
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-10

General
Standards

Approvals
Approvals

Climatic proofing
Ambient temperature
Operation

ϑ

°C

-30 - +50

-30 - +50

-30 - +50

-30 - +50

-30 - +50

-30 - +50

-30 - +50

-30 - +50

-30 - +50

Storage

ϑ

°C

-50 - +70

-50 - +70

-50 - +70

-50 - +70

-50 - +70

-50 - +70

-50 - +70

-50 - +70

-50 - +70

m

0 - 2000 m, above that each 100 m 0.5% Derating

As required

As required

As required

Altitude
Mounting position

0 - 2000 m, above that each 100 m 0.5% Derating

As required

As required

As required

As required

As required

Protection type

IP20 (terminals IP00)

IP20 (terminals IP00)

IP20 (terminals IP00)

IP20 (terminals IP00)

IP20 (terminals IP00)

Integrated

Protection type IP40 can be achieved on all sides with covers SS-IP20-N.

As required

Degree of protection
An IP20 degree of protection can be achieved on all sides by using optional terminal covers SS-IP20-TU.

Protection against direct contact

Finger- and back-of-hand proof

Overvoltage category/pollution
degree
Shock resistance

II/3

II/3

II/3

II/3

Finger- and back-of-hand proof
II/3

II/3

II/3

II/3

II/3

15 g

15 g

15 g

15 g

15 g

15 g

15 g

15 g

15 g

Radio interference level
(IEC/EN 55011)
Heat dissipation

A

A

A

A

A

A

A

A

A

W

25

25

25

25

25

25

25

25

25

Weight

kg

2.6

2.6

4.8

4.8

18.6

18.6

18.6

18.6

18.6

V AC

200 - 600

200 - 600

200 - 600

200 - 600

200 - 600

200 - 600

200 - 600

200 - 600

200 - 600

-

-

-

-

200 - 690

200 - 690

200 - 690

-

-

Rated operating voltage

Ue

…V3S
Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Ie

A

37

66

105

135

180

240

304

361

420

S801+, S811+

Main conducting paths

Rated operational current
Device (AC-53)
Assigned motor rating
(Standard connection, In-Line)
at 230 V, 50 Hz

P

kW

7.5

18.5

30

37

55

75

90

110

132

at 400 V, 50 Hz

P

kW

18.5

30

55

75

90

132

160

200

200

at 500 V, 50 Hz

P

kW

22

45

55

90

110

160

200

250

250

at 690 V, 50 Hz

P

kW

-

-

-

-

160

200

250

-

-

at 200 V, 60 Hz

P

HP

10

20

30

40

60

75

100

125

125

at 230 V, 60 Hz

P

HP

10

20

40

50

60

75

100

150

150

at 480 V, 60 Hz

P

HP

25

50

75

100

150

200

250

300

350

at 600 V, 60 Hz

P

HP

30

60

100

125

150

200

300

350

450

✓

✓

✓

✓

✓

✓

✓

✓

✓

1 x (70 - 240)
1 x (70 - 240)
2 x (25 - 240)
2 x (25 - 240)
1 x (70 - 240)
1 x (70 - 240)
2 x (25 - 240)
2 x (25 - 240)
1 x (70 - 240)
1 x (70 - 240)
2 x (25 - 240)
2 x (25 - 240)
1 x (4 - 500 kcmil)
1 x (4 - 500 kcmil)
2 x (4 - 500 kcmil)
2 x (4 - 500 kcmil)
25.5 (≤ 150 mm²);
25.5 (≤ 150 mm²);
28.3 (> 150 mm²)
28.3 (> 150 mm²)
4 mm Hexagon socket-head screw

1 x (70 - 240)
2 x (25 - 240)
1 x (70 - 240)
2 x (25 - 240)
1 x (70 - 240)
2 x (25 - 240)
1 x (4 - 500 kcmil)
2 x (4 - 500 kcmil)
25.5 (≤ 150 mm²);
28.3 (> 150 mm²)

1 x (70 - 240)
2 x (25 - 240)
1 x (70 - 240)
2 x (25 - 240)
1 x (70 - 150)
2 x (25 - 240)
1 x (4 - 500 kcmil)
2 x (4 - 500 kcmil)
-

1 x (70 - 240)
2 x (25 - 240)
1 x (70 - 240)
2 x (25 - 240)
1 x (70 - 150)
2 x (25 - 240)
1 x (4 - 500 kcmil)
2 x (4 - 500 kcmil)
-

-

-

Internal bypass contacts
Terminal capacities
Cable lengths
Solid

mm2

1 x (2.5 - 35)

1 x (2.5 - 35)

1 x (2.5 - 95)

1 x (2.5 - 95)

Flexible with ferrule

mm2

1 x (2.5 - 35)

1 x (2.5 - 35)

1 x (2.5 - 95)

1 x (2.5 - 95)

Stranded

mm2

1 x (2.5 - 35)

1 x (2.5 - 35)

1 x (2.5 - 95)

1 x (2.5 - 95)

Solid or stranded

AWG

1 x (14 - 2)

1 x (14 - 2)

1 x (14 - 4/0)

1 x (14 - 4/0)

Tightening torque

Nm

4 (≤ 6 mm²); 4.5 (≤ 10 mm²); 5 (≤ 25 mm²); 5.6 (> 25 mm²)

11.3

11.3

Screwdriver (PZ: Pozidriv)

mm

1,5 x 6 mm

4 mm Hexagon sockethead screw

4 mm Hexagon sockethead screw

CA04020001Z-EN-INT

www.eaton.eu

1,5 x 6 mm

CA04020001Z-EN-INT

www.eaton.eu

144

Soft starter S801+, S811+

Soft starter S801+, S811+

Basic devices

145

Basic devices

S8x1+N37…

S8x1+N66…

S8x1+R10…

S8x1+R13…

S8x1+T18…

S8x1+T24…

S8x1+T30…

S8x1+U36…

S8x1+U42…

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
3 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
5 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
7 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
9 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
12 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
15 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
18 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
21 x (12 - 14)
2 x (12 - 14)
0.4

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

Control cables
Solid

mm2

Flexible with ferrule

mm2

Stranded

mm2

Solid or stranded

AWG

Tightening torque

Nm

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (12 - 14)
2 x (12 - 14)
0.4

Screwdriver

mm

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

Control circuit
Regulator supply
Notes
External supply voltage
Voltage

Us

V

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

Current consumption

Ie

mA

1000

1000

1000

1000

1000

1000

1000

1000

1000

IPeak

mA/ms

10.000 / 15

10.000 / 15

10.000 / 15

10.000 / 15

10.000 / 15

10.000 / 15

10.000 / 15

10.000 / 15

10.000 / 15

V DC

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

mA

100

100

100

100

100

100

100

100

100

V DC

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

V DC

3

3

3

3

3

3

3

3

3

ms

100

100

100

100

100

100

100

100

100

ms

100

100

100

100

100

100

100

100

100

Current consumption at peak
performance (close bypass)
at 24 V DC
Digital inputs
Control voltage
DC-operated
Current consumption 24 V
External 24 V (no-load)
Pick-up voltage
DC-operated
Drop-out voltage
DC operated
Pick-up time
DC operated
DC operated

S801+, S811+

Drop-out time
Relay outputs
Number

2

2

2

2

2

2

2

2

2

Voltage range

V AC

120 V AC/DC

120 V AC/DC

120 V AC/DC

120 V AC/DC

120 V AC/DC

120 V AC/DC

120 V AC/DC

120 V AC/DC

120 V AC/DC

AC-11 current range

A

3 A, AC-11

3 A, AC-11

3 A, AC-11

3 A, AC-11

3 A, AC-11

3 A, AC-11

3 A, AC-11

3 A, AC-11

3 A, AC-11

Acceleration

s

180

180

180

180

180

180

180

180

180

Deceleration

s

0 - 60

0 - 60

0 - 60

0 - 60

0 - 60

0 - 60

0 - 60

0 - 60

0 - 60

%

85

85

85

85

85

85

85

85

85

%

100

100

100

100

100

100

100

100

100

50 Hz

ms

2000

2000

2000

2000

2000

2000

2000

2000

2000

60 Hz

ms

2000

2000

2000

2000

2000

2000

2000

2000

2000

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

Soft start function
Ramp times

Start pedestal
Kickstart
Voltage
Duration

Fields of application
Fields of application

Soft starting of three-phase asynchronous motors

3-phase motors

✓

✓

Soft starting of three-phase asynchronous motors
✓

Functions
Fast switching (semiconductor
contactor)
Soft start function

- (minimum ramp time 1s)

Reversing starter

External solution required (reversing contactor)

Suppression of closing transients

✓

✓

✓

✓

✓

✓

✓

✓

✓

Current limitation

✓

✓

✓

✓

✓

✓

✓

✓

✓

Overload monitoring

✓

✓

✓

✓

✓

✓

✓

✓

✓

Underload monitoring

✓

✓

✓

✓

✓

✓

✓

✓

✓

10

10

10

10

10

10

10

10

10

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Fault memory

Faults

Suppression of DC components for
motors
Potential isolation between power and
control sections
Built-in interfaces

CA04020001Z-EN-INT

✓

www.eaton.eu

- (minimum ramp time 1s)
✓

✓

✓

✓

External solution required (reversing contactor)

CA04020001Z-EN-INT

www.eaton.eu

146

Soft starter S801+, S811+

Soft starter S801+, S811+

Basic devices

147

Basic devices

S8x1+V36…

S8x1+V42…

S8x1+V50…

S8x1+V65…

S8x1+V72…

S8x1+V85…

S8x1+V10…

IEC/EN 60947-4-2
UL 508
CSA22.2-14-1995
GB14048
CE

IEC/EN 60947-4-2
UL 508
CSA22.2-14-1995
GB14048
CE

IEC/EN 60947-4-2
UL 508
CSA22.2-14-1995
GB14048
CE

IEC/EN 60947-4-2
UL 508
CSA22.2-14-1995
GB14048
CE

IEC/EN 60947-4-2
UL 508
CSA22.2-14-1995
GB14048
CE

IEC/EN 60947-4-2
UL 508
CSA22.2-14-1995
GB14048
CE

IEC/EN 60947-4-2
UL 508
CSA22.2-14-1995
GB14048
CE

UL
UL
CSA
CSA
C-Tick
C-Tick
CCC
CCC
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-10

UL
CSA
C-Tick
CCC

UL
CSA
C-Tick
CCC

UL
UL
CSA
CSA
C-Tick
C-Tick
CCC
CCC
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-10

UL
CSA
C-Tick
CCC

General
Standards

Approvals
Approvals

Climatic proofing
Ambient temperature
Operation

ϑ

°C

-30 - +50

-30 - +50

-30 - +50

-30 - +50

-30 - +50

-30 - +50

-30 - +50

Storage

ϑ

°C

-50 - +70

-50 - +70

-50 - +70

-50 - +70

-50 - +70

-50 - +70

-50 - +70

m

0 - 2000 m, above that each 100 m 0.5% Derating

Altitude
Mounting position

0 - 2000 m, above that each 100 m 0.5% Derating

As required

As required

As required

As required

As required

As required

As required

Protection type

IP20 (terminals IP00)

IP20 (terminals IP00)

IP20 (terminals IP00)

IP20 (terminals IP00)

IP20 (terminals IP00)

IP20 (terminals IP00)

IP20 (terminals IP00)

Integrated

Protection type IP40 can be achieved on all sides with covers SS-IP20-N.

Degree of protection
Protection type IP40 can be achieved on all sides with covers SS-IP20-N.

Protection against direct contact

Finger- and back-of-hand proof

Overvoltage category/pollution
degree
Shock resistance

II/3

II/3

II/3

II/3

Finger- and back-of-hand proof
II/3

II/3

II/3

15 g

15 g

15 g

15 g

15 g

15 g

15 g

Radio interference level
(IEC/EN 55011)
Heat dissipation

A

A

A

A

A

A

A

W

25

25

25

25

25

25

25

Weight

kg

41.4

41.4

41.4

41.4

41.4

41.4

41.4

V AC

200 - 600

200 - 600

200 - 600

200 - 600

200 - 600

200 - 600

200 - 600

200 - 690

200 - 690

200 - 690

200 - 690

200 - 690

200 - 690

-

Rated operating voltage

Ue

…V3S
Supply frequency

fLN

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Ie

A

361

420

500

650

720

850

1000

S801+, S811+

Main conducting paths

Rated operational current
Device (AC-53)
Assigned motor rating
(Standard connection, In-Line)
at 230 V, 50 Hz

P

kW

110

132

160

200

200

200

200

at 400 V, 50 Hz

P

kW

200

200

250

315

400

450

560

at 500 V, 50 Hz

P

kW

250

250

315

450

500

560

630

at 690 V, 50 Hz

P

kW

315

400

500

630

630

710

-

at 200 V, 60 Hz

P

HP

125

150

150

200

200

200

200

at 230 V, 60 Hz

P

HP

150

150

200

250

250

350

400

at 480 V, 60 Hz

P

HP

300

350

400

500

600

600

750

at 600 V, 60 Hz

P

HP

350

450

500

600

750

850

850

✓

✓

✓

✓

✓

✓

✓

2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (4 - 500 kcmil)
4 x (4 - 500 kcmil)
6 x (4 - 500 kcmil)
-

2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (4 - 500 kcmil)
4 x (4 - 500 kcmil)
6 x (4 - 500 kcmil)
-

2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (4 - 500 kcmil)
4 x (4 - 500 kcmil)
6 x (4 - 500 kcmil)
-

2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (4 - 500 kcmil)
4 x (4 - 500 kcmil)
6 x (4 - 500 kcmil)
-

2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (4 - 500 kcmil)
4 x (4 - 500 kcmil)
6 x (4 - 500 kcmil)
-

2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (4 - 500 kcmil)
4 x (4 - 500 kcmil)
6 x (4 - 500 kcmil)
-

-

-

-

-

-

-

Internal bypass contacts
Terminal capacities
Cable lengths
Solid

mm2

Flexible with ferrule

mm2

Stranded

mm2

Solid or stranded

AWG

Tightening torque

Nm

2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (120 - 240)
4 x (70 - 240)
6 x (120 - 240)
2 x (4 - 500 kcmil)
4 x (4 - 500 kcmil)
6 x (4 - 500 kcmil)
-

Screwdriver (PZ: Pozidriv)

mm

-

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

148

Soft starter S801+, S811+

Soft starter S801+, S811+

Basic devices

149

Basic devices

S8x1+V36…

S8x1+V42…

S8x1+V50…

S8x1+V65…

S8x1+V72…

S8x1+V85…

S8x1+V10…

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
30 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
33 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
36 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
39 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
42 x (12 - 14)
2 x (12 - 14)
0.4

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
45 x (12 - 14)
2 x (12 - 14)
0.4

Control cables
Solid

mm2

Flexible with ferrule

mm2

Stranded

mm2

Solid or stranded

AWG

Tightening torque

Nm

1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
1 x (2.5 - 4)
2 x (1.0 - 2.5)
27 x (12 - 14)
2 x (12 - 14)
0.4

Screwdriver

mm

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

0,6 x 3,5

Control circuit
Regulator supply
Notes
External supply voltage
Voltage

Us

V

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

Current consumption

Ie

mA

1400

1400

1400

1400

1400

1400

1400

IPeak

mA/ms

10.000 / 15

10.000 / 15

10.000 / 15

10.000 / 15

10.000 / 15

10.000 / 15

10.000 / 15

V DC

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

24 V DC +10 %/- 10 %

mA

100

100

100

100

100

100

100

V DC

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

21.6 - 26.4

V DC

3

3

3

3

3

3

3

ms

100

100

100

100

100

100

100

ms

100

100

100

100

100

100

100

Current consumption at peak
performance (close bypass)
at 24 V DC
Digital inputs
Control voltage
DC-operated
Current consumption 24 V
External 24 V (no-load)
Pick-up voltage
DC-operated
Drop-out voltage
DC operated
Pick-up time
DC operated
DC operated

S801+, S811+

Drop-out time
Relay outputs
2

2

2

2

2

2

2

Voltage range

Number
V AC

120 V AC/DC

120 V AC/DC

120 V AC/DC

120 V AC/DC

120 V AC/DC

120 V AC/DC

120 V AC/DC

AC-11 current range

A

3 A, AC-11

3 A, AC-11

3 A, AC-11

3 A, AC-11

3 A, AC-11

3 A, AC-11

3 A, AC-11

Acceleration

s

180

180

180

180

180

180

180

Deceleration

s

0 - 60

0 - 60

0 - 60

0 - 60

0 - 60

0 - 60

0 - 60

%

85

85

85

85

85

85

85

%

100

100

100

100

100

100

100

50 Hz

ms

2000

2000

2000

2000

2000

2000

2000

60 Hz

ms

2000

2000

2000

2000

2000

2000

2000

✓

✓

Soft start function
Ramp times

Start pedestal
Kickstart
Voltage
Duration

Fields of application
Fields of application

Soft starting of three-phase asynchronous motors

3-phase motors

✓

✓

Soft starting of three-phase asynchronous motors
✓

✓

✓

✓

✓

Functions
Fast switching (semiconductor
contactor)
Soft start function

- (minimum ramp time 1s)

Reversing starter

External solution required (reversing contactor)

Suppression of closing transients

✓

✓

✓

✓

✓

✓

✓

Current limitation

✓

✓

✓

✓

✓

✓

✓

Overload monitoring

✓

✓

✓

✓

✓

✓

✓

Underload monitoring

✓

✓

✓

✓

✓

✓

✓

10

10

10

10

10

10

10

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Fault memory

Faults

Suppression of DC components for
motors
Potential isolation between power and
control sections
Built-in interfaces

CA04020001Z-EN-INT

✓

www.eaton.eu

- (minimum ramp time 1s)
✓

✓

✓

✓

External solution required (reversing contactor)

CA04020001Z-EN-INT

www.eaton.eu

150

Soft starter S801+, S811+
Basic devices

Dimensions
Basic devices

174.5 mm (6.87")
187 mm (7.36")

S8x1+N…

165 mm (6.50")

50 mm
(1.97")
67.5 mm
(2.66")

201 mm (7.91")

189 mm (7.44")

S8x1+R…

90 mm (3.54")

170 mm (6.69")

111 mm (4.37")

299 mm (11.77")
323 mm (12.72")

S8x1+T…

75 mm
75 mm
(2.95")
(2.95")
196 mm (7.72")

CA04020001Z-EN-INT

www.eaton.eu

164 mm (6.46")

Soft starter S801+, S811+

151

Basic devices

299 mm (11.77")
323 mm (12.72")

S8x1+U…

182 mm (7.16")

66.4 mm
66.4 mm
(2.6")
(2.6")
196 mm (7.72")

95 mm (3.74")

S801+, S811+

421 mm (16.57")

385 mm (15.16")

S8x1+V…

188 mm (7.40")

281 mm (11.06")

CA04020001Z-EN-INT

www.eaton.eu

Rapid Link 4.0 distributed, electronic drive
system
Standardized installation procedures, the ability to directly and locally configure parameters with a plug and play configuration, and networked communications – these are
the needs of material handling system applications today when it comes to state-of-theart drive engineering and the systems it produces.
Eaton delivers a modern answer with the Rapid Link 4.0 distributed electronic drive
system. With its flexible power spectrum, its simple handling and its intelligent programming options, this new motor starter and variable frequency drives generation is the first
choice for all kinds of conveying engineering applications.
RAMO electronic motor starters
Electronic DOL and reversing starters with a lifespan of more than 10 million switching operations, IP 65 degree of protection. Rated adjustable operational current of 0.3 – 6.6 A with threephase mains connection of 400 V; allocated motor output of 0.09 – 3.0 kW
RAMO-D…: DOL starter
RAMO-W…: reversing starter
RASP speed controllers
Frequency-controlled motor starters with Volts-per-Hertz control (V/Hz control) and slip compensation or voltage-controlled vector control, as well as an integrated radio interference suppression filter (EMC), IP65 degree of protection.
RASP-2…: Rated operational current of 0.48 – 2.4 A with three-phase mains connection of
400 V; assigned motor output of up to 0.75 kW
RASP-3…: Rated operational current of 0.66 – 3.3 A with three-phase mains connection of
400 V; assigned motor output of up to 1.1 kW
RASP-4…: Rated operational current of 0.86 – 4.3 A with three-phase mains connection of
400 V; assigned motor output of up to 1.5 kW
RASP-5…: Rated operational current of 1.12 – 5.6 A with three-phase mains connection of
400 V; allocated motor output of up to 2.2 kW

Rapid Link 4.0

System overview

153

154

Description
Application and function

156

Key to type references

157

Ordering
Motor starter RAMO

158

RASP speed controllers

159

Accessories

160

Engineering
General information on Engineering

164

Block diagram RAMO-D DOL starter

166

Block diagram RAMO-W reversing starter

168

Block diagram RASP

170

Technical data
Motor starter RAMO

172

RASP speed controllers

172

Accessories

174

Dimensions
175

RASP speed controllers

176

Accessories

177

Rapid Link

Motor starter RAMO

CA04020001Z-EN-INT

www.eaton.eu

154

Rapid Link 4.0
Rapid Link 4.0

System overview
Rapid Link 4.0

1
2
3

4

7

3 AC, (N), PE
50/60 Hz
5

12

10

8

10
6

9
11

M
3

12

13

M
3

14
16
15

18
19

20

CA04020001Z-EN-INT

www.eaton.eu

21

22

17

11

Rapid Link 4.0

155

Rapid Link 4.0
Function modules

Motor starter (Motor Control Unit)

Motor feeder

1

Three-phase electronic DOL starter or
reversing starter
→ page 158

Speed controller RASP
(Speed Control Unit)

Unscreened motor cable

Power and data bus

5

→ page 160

Screened motor supply cable (EMC)
2

Three phase frequency-controlled motor
starter (fixed speeds, two rotational
directions, adjustable acceleration and
deceleration ramps)
→ page 159

6

Energy supply (3 AC 400 V) via circuitbreaker for overload and short-circuit
protection

7

for protection against short-circuit and
overload

→ page 160

AS-Interface® feeder unit

8

AS-Interface® flat cable

9

AS-Interface® connection cable

10

→ page 163
3

AS-Interface® junction

Fan
for operation at high temperatures without
derating
→ page 160

11

→ page 163
4

12

Sensor connection
→ page 163

End-piece for flat cable

13

→ page 162
14

distributor module
for 400-V-AC incoming unit of the flat cable
→ page 161

Power connection cable

15

to flexible busbar junction
→ page 160

flexible busbar junction

16

→ page 161

Ribbon cable for 400 V AC

17

→ page 160

Power connection cable

18

to round cable junction
→ page 162

Round cable junction

19

→ page 162

Round cable for 400 V AC

20

Power connection cable

21

to round cable junction
→ page 162

Round cable junction

22

→ page 162

CA04020001Z-EN-INT

www.eaton.eu

Rapid Link

operating unit
for parameter setting
→ page 160

156

Rapid Link 4.0
System

System

Rapid Link 4.0 is a modern, efficient drive and PLC. It is the competent further
development of the Rapid Link 2.1/3.0 device series, suitable for simple and
complex tasks in all aspects of material handling. For example in airports,
industrial production and logistics centers.
The Rapid Link system consists of the RAMO electronic motor starters and the
RASP frequency controlled motor starters.

The RAMO and RASP motor starters are designed with IP65 protection and
can be installed in direct proximity to the drive. Their versions and mounting
depend on the required specifications and the local conditions.
The RAMO and RASP are connected with standard plug connectors to the
energy and databus systems predominantly used in material handling systems
(AS-Interface). Connection can be implemented without interrupting the
required location. This simplifies installation and reduces the wiring
requirement.

Overview of features
RAMO 4.0 electronic motor starters

Frequency controlled motor starter RASP 4.0

Application and function
The RAMO motor starters enable the electronic DOL or reversing starting of
three-phase motors in automatic or manual mode. The electronic overload
protection for motor ratings from 90 W to 3 kW at 400 V (50/60 Hz) is configured
with DIP switches. Full motor protection is ensured when used in connection
with temperature sensors.
The operating mode is set via the AUTO - OFF/RESET – MANUAL key switch
and can be combined with the 'Quick stop' and 'Interlocked manual operation'
via the two sensor inputs (M12 sockets). Operating states are diagnosed and
error messages (Reset) acknowledged on the device or via the AS-Interface.
RAMO is available in different versions:
• with actuator output (24 V DC) for a direct actuation of external switching
devices, e.g. solenoid valves.
• with electronic actuation for mechanical motor brakes.
• with lockable repair switch for diagnostic and maintenance work, making it
possible to safely de-energize the device locally.

Application and function
The RASP motor starter enables the infinitely variable speed control of
three-phase motors in the range from zero to 320 Hz . The standard size
for 400 V (50/60 Hz) is assigned four motor ratings: 0.75 kW, 1.1 kW, 1.5 kW
and 2.2 kW. Full motor protection is ensured by the adjustable current
limitation (I2t controller).
The operating mode is set via the AUTO - OFF/RESET – MANUAL key switch
and can be combined with the 'Quick stop' and 'Interlocked manual operation'
via the two sensor inputs (M12 sockets). Settable fixed frequencies and
cyclical program sequences extend the application range and relieve the load
on the higher-level head-end controller (PLC). Operating states are diagnosed
and error messages (Reset) acknowledged on the device or via the ASInterface. A hand-held programmer and a PC interface are available for the
parameterization of the variable frequency drive module.
RASP is available in different versions:
• with integrated brake chopper with braking resistance for dynamic braking.
• with electronic actuation for mechanical motor brakes.
• with lockable repair switch for diagnostic and maintenance work, making it
possible to safely de-energize the device locally.

Essential features
• Standard size in square enclosure. The bottom section with the two power
terminals (power plug, motor feeder socket) and the repair and maintenance
switch can be turned 90° clockwise and counterclockwise.
• Long lifespan up to 10 million switching operations and up to 3,000 switch
cycles per hour at 2.2 kW.
• Rated operational current 6.6 A.
• Operating and ambient temperature from -10 to +55 °C, without derating.
• Monitoring of thermistor and motor cable.
• Maximum motor cable length: 10 m.

CA04020001Z-EN-INT

www.eaton.eu

Essential features
• Standard size in square enclosure. The bottom section with the two power
terminals (power plug, motor feeder socket) and the repair and maintenance
switch can be turned 90° clockwise and counterclockwise.
• Monitoring of thermistor and motor cable.
• Operating and ambient temperatures from 0 to +40 °C without derating, with
optional fan in the performance range up to 1.5 kW max. +55 °C.
• Rated operational current: 2.4 A, 3.3 A, 4.3 A, 5.6 A
• EMC class C3 in 2nd environment
• Maximum motor cable length: 5 m.

Rapid Link 4.0

157

Key to type references
Electronic motor starters RAMO
Key to type references

RAMO - D A 2 AI1 S - C32

R S1

Type

Version

RAMO

S1 = Standard

Starters

Option

D
=
DOL starter
W
=
Reversing starter

0 = no option
R = manual override switch

Output

Power connections

0 = no output
A = Actuator output

C32 = pluggable at bottom
Ambient temperature
during operation

Breaking resistance
0 = no breaking voltage
2 = 230 V AC
4 = 400 V AC

S = Standard (-10 - 55 °C)

AS-Interface®
AI1 = S-7.4
AI2 = S-7.A.E.

Frequency controlled motor starter RASP

R S1

Type

Version

RAMO

S1 = Standard

Starters

Option

D
=
DOL starter
W
=
Reversing starter

0 = no option
R = manual override switch

Output

Power connections

0 = no output
A = Actuator output

C32 = pluggable at bottom

Breaking resistance
0 = no breaking voltage
2 = 230 V AC
4 = 400 V AC

Rapid Link

RAMO - D A 2 AI1 S - C32

Ambient temperature
during operation
S = Standard (-10 - 55 °C)

AS-Interface®
AI1 = S-7.4
AI2 = S-7.A.E.

CA04020001Z-EN-INT

www.eaton.eu

158

Rapid Link 4.0
Motor starter RAMO

Ordering
Rated
operational
current
Ie

Control voltage external
brake (50/60 Hz)1)

Actuator
output2)

A

V AC

Number

S-7.4 for 31 modules

S-7.A.E. for 62 modules

Motor starter RAMO

AS-Interface
profile cable

6.6

-

-

✓

-

6.6

230

-

✓

-

6.6

230

-

-

✓

6.6

230

1

✓

-

6.6

400

-

✓

-

6.6

400

-

-

✓

6.6

400

1

✓

-

6.6

-

-

✓

-

6.6

230

-

✓

-

6.6

230

-

-

✓

6.6

400

-

✓

-

6.6

400

-

-

✓

-

-

✓

-

6.6

230

-

✓

-

6.6

230

-

-

✓

6.6

230

1

✓

-

6.6

400

-

✓

-

6.6

400

-

-

✓

6.6

400

1

✓

-

6.6

-

-

✓

-

6.6

230

-

✓

-

6.6

230

-

-

✓

6.6

400

-

✓

-

6.6

400

-

-

✓

Part no.
Article no.

Price
see price list

Std. pack

Motor starter RAMO
Rated operational voltage 400 V AC
DOL starters
RAMO-D00AI1S-C320S1
150150
RAMO-D02AI1S-C320S1
150152
RAMO-D02AI2S-C320S1
171776
RAMO-DA2AI1S-C320S1
164321
RAMO-D04AI1S-C320S1
169799
RAMO-D04AI2S-C320S1
171778
RAMO-DA4AI1S-C320S1
169800

1 off

RAMO-D00AI1S-C32RS1
150158
RAMO-D02AI1S-C32RS1
150160
RAMO-D02AI2S-C32RS1
171782
RAMO-D04AI1S-C32RS1
169801
RAMO-D04AI2S-C32RS1
171784

1 off

RAMO-W00AI1S-C320S1
150151
RAMO-W02AI1S-C320S1
150153
RAMO-W02AI2S-C320S1
171777
RAMO-WA2AI1S-C320S1
164322
RAMO-W04AI1S-C320S1
169802
RAMO-W04AI2S-C320S1
171779
RAMO-WA4AI1S-C320S1
169803

1 off

RAMO-W00AI1S-C32RS1
150159
RAMO-W02AI1S-C32RS1
150161
RAMO-W02AI2S-C32RS1
171783
RAMO-W04AI1S-C32RS1
169804
RAMO-W04AI2S-C32RS1
171785

1 off

with manual override switch

Reversing starter
with selector switch REV - OFF - FWD
6.6

with manual override switch

Instructions

1) for

actuation of motors with mechanical brake
with external 24V DC supply

2) Operation

CA04020001Z-EN-INT

www.eaton.eu

Rapid Link 4.0

159

RASP speed controllers
RASP speed controllers

Rated
operatio
nal
current1)

assigned motor
rating P2)

Control
voltage
external
brake
(50/60 Hz)3)

with braking resistance4)
Part no.
Article no.

Price
see price
list

Part no.
Article no.

Price
see price
list

Std. pack

at 400 V, 50 Hz
Ie

P

A

A

V AC

RASP speed controllers
Rated operational voltage 400 V AC
AS-Interface profile cable S-7.4 for 31 modules
2.4
-

-

2.4

-

230

2.4

-

400

3.3

-

-

3.3

-

230

3.3

-

400

4.3

-

-

4.3

-

230

4.3

-

400

5.6

-

-

5.6

-

230

5.6

-

400

2.4

-

-

2.4

-

230

2.4

-

400

3.3

-

-

3.3

-

230

3.3

-

400

4.3

-

-

4.3

-

230

4.3

-

400

5.6

-

-

5.6

-

230

5.6

-

400

RASP-200AI1S0-C320S1
150168
RASP-202AI1S0-C320S1
150176
RASP-204AI1S0-C320S1
169805
RASP-300AI1S0-C320S1
150169
RASP-302AI1S0-C320S1
150177
RASP-304AI1S0-C320S1
169806
RASP-400AI1S0-C320S1
150170
RASP-402AI1S0-C320S1
150178
RASP-404AI1S0-C320S1
169807
RASP-500AI1SL-C320S1
150171
RASP-502AI1SL-C320S1
150179
RASP-504AI1SL-C320S1
169808

RASP-210AI1S0-C320S1
150172
RASP-212AI1S0-C320S1
150180
RASP-214AI1S0-C320S1
169809
RASP-310AI1S0-C320S1
150173
RASP-312AI1S0-C320S1
150181
RASP-314AI1S0-C320S1
169810
RASP-410AI1S0-C320S1
150174
RASP-412AI1S0-C320S1
150182
RASP-414AI1S0-C320S1
169811
RASP-510AI1SL-C320S1
150175
RASP-512AI1SL-C320S1
150183
RASP-514AI1SL-C320S1
169812

1 off

RASP-200AI1S0-C32RS1
150200
RASP-202AI1S0-C32RS1
150208
RASP-204AI1S0-C32RS1
169813
RASP-300AI1S0-C32RS1
150201
RASP-302AI1S0-C32RS1
150209
RASP-304AI1S0-C32RS1
169814
RASP-400AI1S0-C32RS1
150202
RASP-402AI1S0-C32RS1
150210
RASP-404AI1S0-C32RS1
169815
RASP-500AI1SL-C32RS1
150203
RASP-502AI1SL-C32RS1
150211
RASP-504AI1SL-C32RS1
169816

RASP-210AI1S0-C32RS1
150204
RASP-212AI1S0-C32RS1
150212
RASP-214AI1S0-C32RS1
169817
RASP-310AI1S0-C32RS1
150205
RASP-312AI1S0-C32RS1
150213
RASP-314AI1S0-C32RS1
169818
RASP-410AI1S0-C32RS1
150206
RASP-412AI1S0-C32RS1
150214
RASP-414AI1S0-C32RS1
169819
RASP-510AI1SL-C32RS1
150207
RASP-512AI1SL-C32RS1
150215
RASP-514AI1SL-C32RS1
169820

1 off

Instructions

Rapid Link

with manual override switch

1) for

normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1
at 60 Hz
2) Rated operational current at an operating frequency of 6 kHz and an ambient air temperature of +40 °C
3) for actuation of motors with mechanical brake
4) integrated brake chopper with braking resistance for dynamic braking

CA04020001Z-EN-INT

www.eaton.eu

160

Rapid Link 4.0
Accessories

Accessories

Std.
pack

Instructions

RASP-KEY-S1
156644

1 off

-

RASP

XMX-CBL-3M4-USB
153448

1 off

-

RASP

RASP-FAN-S1
156643

1 off

-

Length
m
2

RAMO

1 off

-

5

RAMO

1 off

-

10

RAMO

RAMO-CM1-2M0
164282
RAMO-CM1-5M0
164283
RAMO-CM1-10M
164284

1 off

-

2

RASP

1 off

-

5

RASP

RASP-CM1-2M0
164285
RASP-CM1-5M0
164286

1 off

-

RAMO-CM1…
RASP-CM1…

SET-M-LOCK
272085

1 off

For padlocks
with hasp
thickness up to
8 mm

RA-C1…

RA-C1-7X4HF
230860

100 
runn. m

Paint film
contaminant/
silicon-free

RAMO
RASP
RA-C1-PLF

RA-C3/C1-1,5HF
290210

1 off

-

Description

For use with

Part no.
Article no.

RASP

Price
see price list

Communications
Operating unit
for setting the device parameters
with non-volatile parameter memory for copying
parameter sets
Equipment supplied: including 1 m connection
cable with RJ45 connectors
BACK
RESET

OK

LOC
REM

I

Programming cable
for connecting the device to the PC
USB
For configuring the device's parameters
with the MaxConnect computer program
RJ 45
with RJ 45 plug and USB plug

Length
3.4 m

Device fans
RASP device fan
for operation at high temperatures without derating
Power supply and control via RASP through M12
plug connector
Enhanced cooling for ambient temperatures of up
to +55 °C for RASP-2…, RASP-3…., and RASP-4...
Spare part for RASP-5...

Motor feeder
Motor cable
for connecting the motor starter to the motor
halogen free, 8 x 1.5 mm2, plastic plug

halogen free, screened,
4 x 1.5 mm2 + 2 x (2 x 0.75 mm2),
plastic plug

Locking brackets
for the safe isolation of the motor cables from power
For motor cables and motor plugs, disconnection
device to EN 60204-1

Power supply at flat cable RA-C1
Flat cable
for 400 V AC/24 V DC decentralized power supply or AS-Interface
halogen free, 7 x 4 mm2

Power connection cable
for connecting the device with the 400 V AC flexible busbar junction
with power plug and plug for flexible busbar
junction, halogen-free, 5 x 1.5 mm2

CA04020001Z-EN-INT

www.eaton.eu

Rapid Link 4.0

161

Accessories

For use with

Part no.
Article no.

Flexible busbar junction 400 V AC/24 V DC
Connection socket for power connection cable
Insulation piercing terminals, terminal
socket with lock mechanism

RA-C1-7X4HF
RA-C3/C1-1,5HF

Protection cover
for protecting the 400 V AC/24 V DC flexible busbar junction
-

Description

Price
see price list

Std. pack

Instructions

RA-C1-PLF
290188

5 off

-

RA-C1-PLF

RA-C1-COV
254693

10 off

-

RA-C1-PLF

RA-C1-VP-PLM
231574

5 off

Order cable gland
V-M25 separately.

RA-C1-AM-7
290214

5 off

Order cable gland
V-M25 or V-M20
separately.

RA-C1-PLM/C3-1M5
112624

1 off

Can be used when
AS‐Interface
implemented in flat
cable.

RA-C1-PLF1
116904

1 off

Can be used when
AS‐Interface
implemented in flat
cable.

RA-C1-AM/C3-1M5
112625

1 off

Can be used when
AS‐Interface
implemented in flat
cable.

RA-C1-VM-7
264244

2 off

Order V-M25/V-M20
cable gland and
RA-C1-DF bushing
separately.

RA-C1-VM-7

RA-C1-DF
264243

10 off

-

RA-C1-7X4HF

RA-C1-VP-AM-2
264315

5 off

Order cable gland
V-M20 separately

RA-C1-7X4HF

RA-C1-FIX
272086

100 off

One set with 100 clips.

Power supply at flat cable RA-C1

Plug insert with hood

Distributor module
for feeding the 400-V-AC/24-V-DC of the ribbon cable with a round cable
Termination with piercing screws,
RA-C1-7X4HF
2 x V-M25 and 2 x V-M20 knockout
plates, connection module with springloaded terminals, connection of round
cables up to 4 mm2.
Power/AS-Interface connection cable
for connecting the device with the 400 V AC AS-Interface flexible busbar junction
Double cable with outgoer plug (flexible RAMO
busbar end) and M12 plug and power
RASP
plug (device end)
RA-C1-PLF1

400 V AC/AS-Interface flexible busbar junction
Connection socket for power/AS-Interface cable
Insulation piercing terminals, terminal
socket with lock mechanism

RA-C1-7X4HF
RA-C1-PLM/C31M5

Power/AS-Interface connection cable
For connecting the device with 400 V AC/24 V DC/AS-Interface flexible busbar
Double cable with connection module
RAMO
(flexible busbar end) and M12 plug as
RASP
well as power plug (device end),
RA-C1-7X4HF
termination with piercing screws,
knockouts
Length 1.5 m
Distributor module
for the 400V AC feeding to the ribbon cable with a round cable
With 3 flexible busbar inputs and 2 round RA-C1-7X4HF
cable inputs
Connection of round cables 4 mm2

Flexible busbar bushing
for bushing for flat cable in distributor module or control cabinet
-

Distributor module
24 V DC control voltage is taken from the ribbon cable
Termination with piercing screws,
connection sockets with screw contacts

Flexible busbars
for fastening the ribbon cable
-

CA04020001Z-EN-INT

www.eaton.eu

Rapid Link

Plug connector for 400 V AC/24 V DC flexible busbar junction

162

Rapid Link 4.0
Accessories

For use with

Part no.
Article no.

RA-C1-7X4HF

For cutting flat cable

for removing casing at the ends of the
flat cable

Description

Length

Price
see price list

Std.
pack

Instructions

RA-C1-END1
290189

10 off

-

RA-C1-7X4HF

RA-C1-CUT
254690

1 off

-

RA-C1-7X4HF

RA-C1-AZ-4
272087

1 off

A standard
engineer's pliers is
required.

RAMO
RASP
RA-C2-S1-4

RA-C3/C2-1,5HF
290211

1 off

-

RA-C3/C2-1,5HF

RA-C2-S1-4
257830

1 off

Equipment supplied:
1 pairs of gaskets
for these cable
diameters, 1 lock
mechanism.

RA-C2-S1-4

RA-C2-SBL
265357

10 off

One set with
10 blanking plugs.

RA-C4-PPB/
C3-1M5
RA-C4-X/
C3-1M5

RA-C4-PB65
116905

1 off

Tools required:
Stripping tool AM16
from Weidmüller or
similar.
Enclosure
continuous seals
must be ordered
separately.

RA-C4-PB65

RA-C4-D13
116907
RA-C4-D15
116908
RA-C4-D17
116909

10 off

-

10 off

-

10 off

-

RA-C4-PB65

RA-C4-D0
116960

10 off

One set with
10 blanking plugs.

RAMO
RASP
RA-C4-PB65

RA-C4-PPB/C3-1M5
116962

1 off

-

m

Power supply at flat cable RA-C1
End-piece
for terminating the ribbon cable
-

Tools

Power supply at round cable RA-C2
Power connection cable
for connecting the device with the round cable junction
with power plug and plug for round
cable junction, halogen-free,
5 x 1.5 mm2

1.5

Round cable junction
Connection socket for power connection cable
for 7 x 2.5/4 mm2, 400 V AC and 24 V DC,
termination with insulation piercing
technology, cable fixing with metal
screws, pre-wired socket insert,
suitable for cable outer diameters
10 - 13 mm.
Blanking plug
for closing the last round cable junction in the power line
-

Power supply at round cable RA-C4
Round cable junction
Connection socket for power cables from 2.5 - 6 mm2
T junction via spring-cage terminal,
1.5 to 6 mm2 and/or plug connection
of 0.5 - 4 mm2, Enclosure IP65

Gasket
Slotted enclosure bushing seal
for Ø 11 - 13 mm EPDM round cable,
silicon free and halogen free, IP65
for Ø 13 - 15 mm EPDM round cable,
silicon free and halogen free, IP65
for Ø 15 - 17 mm EPDM round cable,
silicon free and halogen free, IP65

RA-C4-PB65
RA-C4-PB65

Blanking plug
for closing off unused housing openings
Enclosure seal, closed, EPDM, silicon
free and halogen free, IP65
Power connection cable
for connecting the device with the round cable junction
Cable 5 x 1.5 mm2, halogen-free, with
RA-C4-PPB plug for round cable
junction, power plug and gasket IP65

CA04020001Z-EN-INT

www.eaton.eu

1.5

Rapid Link 4.0

163

Accessories

Description

Std.
pack

Instructions

RA-C4-X/C3-1M5
116961

1 off

-

RA-C4-PB65

RA-C4-PPB
116906

10 off

-

RA-C1-AM-7
RA-C1-AM/C31M5
RA-C1-VP-AM-2

RA-C1-AZPG
112978

1 off

-

RAMO
RASP

ZB2-100-AZ1
082667

1 off

-

1

RASP
RASP

RA-XAZ2-1M
292253

1 off

-

1

RAMO
RASP

RA-XM12-1M
272057

1 off

Pins 1, 3, 4 are
assigned

RASP

RA-XM12-Y
290424

1 off

-

RAMO
RASP

M22-ES-MS1
216416

5 off

-

Length

For use with

Part no.
Article no.

RAMO
RASP
RA-C4-PB65

Price
see price list

m
Power connection cable for user assembly
for connecting the device with the round cable junction
Cable 5 x 1.5 mm2 halogen free, with
ferrules, power plug and IP65 gasket

1.5

Plug connectors
for wiring the power connection cable for user assembly
Plug with spring-cage terminal
0.5 - 4 mm2, printed with 1; N; 2; PE; 3.

Connection clip for AS-Interface flat cable
to AS-Interface incomer/outgoer for connection modules
with integrated AS‐Interface
overvoltage protection, protection
against interference on switch
operations or short-circuit, cable
termination with insulation
displacement
AS-Interface link
M12 connection socket for AS-Interface connection cable
IDC termination

24V/AS-Interface connection cable
for supplying the device with 24 V/AS-Interface
with M12 socket and double outgoer for
AS-Interface and 24 V, cable
termination with insulation
displacement

AS-Interface connection cable
for connecting the device with AS-Interface junction
with M12 socket and M12 plug, 3-pole
Y connector
For connecting up to 2 sensors per M12 socket
-

Rapid Link

AS-Interface connection and sensors

AS-Interface connection and sensors
Spare keys
for AUTO - OFF/RESET - HAND key-switches
Lock mechanism MS1

CA04020001Z-EN-INT

www.eaton.eu

164

Rapid Link 4.0
General information on Engineering

The Rapid Link 4.0 electronic drive system enables remote and flexible installation
in the direct proximity of the drive unit. The entire system is designed with protection
to IP65. All electrical connections (mains voltage, motor feeder, sensors) are
implemented simply with the standard connectors that are primarily used in
materials handling applications.

①

②
③

⑤

④


a
b
c
d
e

Sensor (light barriers)
RAMO
Motor connection cable
Mains connection on power bus
AS-Interface

Motor starter selection

Electrical mains connection

Safety and protective device

EMC compliance

All motor starters (RAMO, RASP) can
provide electronic motor protection
and the additional connection of
temperature sensors (thermistor,
ThermoClick, PTC). The motor starters
are available in the following variants,
with or without a lockable repair
switch (mains transfer switch):

The motor starters can be connected
to and operated on 400 V three-phase,
star point-earthed AC supply systems
(in accordance with IEC 60364)
without any restriction. The neutral
conductor must be connected for
motor starter variants that actuate a
230 V motor brake.

The power bus must have shortcircuit protection. The length of the
power bus depends on the upstream
group protection. Calculations for
design examples are provided in the
Rapid Link manual (MN03406003Z):

All motor starters observe the
required EMC limit values when
connected as specified. The RASP
frequency-controlled motor starter
must be provided with a shielded
motor cable (RASP-CM1-…) and
installed with the specified EMC
measures. The internal RFI filter
then allows operation in accordance
with category C3 in the second
environment.

• RAMO-D, electronic DOL starter for
one operating direction.
• RAMO-W, electronic reversing
starter (two operating directions).
• RASP, frequency-controlled motor
starter with several speeds for two
operating direction in assigned
ratings.

• PKZM0-25 motor-protective circuitbreaker, max. approx. 40 m.
• FAZ C25/3 miniature circuit-breaker,
max. approx. 60 m.
• PKE32/XTU-32 system protective
circuit-breaker, 50 m to 220 m.
The group protective devices listed
here protect:
• the power bus from overloads and
short-circuits.
• the spur lines to the motor starter
(RAMO, RASP) from overloads and
short-circuits.
• the motor feeder of the RAMO
On the RASP frequency-controlled
motor starter, the motor feeder is
protected by the internal variable
frequency drive.
When using residual current devices,
a Type B AC/DC sensitive residual
current circuit-breaker must be used
with the RASP frequency-controlled
motor starter.

CA04020001Z-EN-INT

www.eaton.eu

Rapid Link 4.0

165

General information on Engineering

Terminal Models
Example RASP:

RA-C1, flat cable system

3 AC, (N), PE
50/60 Hz

①

②

Connection from below (standard)

• a three-phase AC motor
(U1, V1, W1, PE),
• a motor brake (B1, B2) with a
control voltage of 230 V AC or
400 V AC,
• a thermistor or temperature switch
(ThermoClick). These connection
cables (T1, T2) can at the same time
be used to monitor the motor cable
and the connection of the motor
feeder plug.
4

a 5-pole power connector for
connecting the 3 AC 400 V mains
voltage, (N), PE.
b 8-pole motor feeder socket as per
DESINA specification.
By rotating the base 90 degrees,
connection is also possible from the
right or left. This makes it possible to
keep the operating and connection
area and the heat sink on the RASP in
the preferred vertical position.

RA-C2, round cable system with plug
connectors

The 8-pole motor feeder can be used
to connect:

6

5

8

1

7

3

PE

3 AC, (N), PE
50/60 Hz

RA-C4, round cable system with
contact connectors
Connection from the right (90 degree
rotation of the base to the left)
Three installation systems are available for connecting the power plug to
the mains:

Device variants with a repair switch
(RAMO-…-C32R…, RASP-….C32R…) ensure that the drive can be
isolated locally from the power supply
for repair or maintenance work, even
when it is still connected. A padlock
can be used to secure the repair
switch.

3 AC, (N), PE
50/60 Hz

PES

B2

B1

T1

T2

U

V

W

≦ 5 m (≦ 16.4 ft)

The electrical connection in the
power section (mains voltage, motor
feeder) is implemented with plug-in
terminals in the base.

PE


M3∼
ϑ

Example: Motor feeder with shielded
motor cable on the RASP

Control level
The control level features a selector
switch (key switch) for selecting
automatic mode and manual mode
locally. The RAMO-W and RASP motor
starters are also provided with a
selector switch for reversing the
motor direction in manual mode.
OFF/RESET

The automatic mode and the
control voltage power supply are
implemented via the AS-Interface.
All connections in the control level
(AS-i, sensors etc.) are implemented
with M12 plug connectors. For this the
M12 connectors just have to be fitted
on [1] and rotated to secure them [2]
(see illustration below).

0
I

II

OFF

FWD

On the RAMO-DA… and RAMO-WA…
a 24 V DC output (max. 1 A, O3)
also makes it possible to control
external actuators (valves, couplings,
indicator lights) directly.

The functions are selected directly on
the motor starter via microswitches.
On the RASP additional settings
(variable frequency drives) can be
made from a hand-held terminal or
from the parameter software.

Rapid Link

REV

The sensor inputs (I3, I4) enable
the Rapid Link motor starters to
execute sensor-controlled functions
immediately and independently of PLC
and bus cycle times:

• Interlocked manual operation,
• Quick Stop,
• Rotation direction change (on
RAMO-W and RASP),
• Controlled speeds (only RASP)

I3

I4

1
2

UV
M
3~

≦ 20 m
(≦ 65.6 ft)

CA04020001Z-EN-INT

www.eaton.eu

166

Rapid Link 4.0
Connection examples

Engineering
Connection examples

4
4
4

4

1

3
6

Optional features:
① RAMO-D…-C32R… Repair and maintenance switch
② Actuation of external brake (230 V), RAMO-Dx2…
③ Actuator output, RAMO-DA…

CA04020001Z-EN-INT

www.eaton.eu

T2

M3∼
ϑ

V
7

3

8

6
4

PE
5

1

①

4
5

2



1

3

L1

1

1

U

7

L2

2

W

T1

3

PE

PE

②

5


3

PE
L3

B1

N

4

4

B2

5

8

1

+24 V
< 160 m A

1

ASi+

2

(0 V)

2

3

0V

4

ASi- (+24 V)

I3

3

1

3

(2)

2

3

I4

1

(4)

1

2

3

3

③

O3
+24 V
≤1A

4

Block diagram RAMO-D DOL starter

Rapid Link 4.0

167

Connection examples

4
4
4

4

1

3

B1

4

① RAMO-D…-C32R… Repair and maintenance switch
② Actuation of external brake (400 V), RAMO-Dx4…
③ Actuator output, RAMO-DA…

CA04020001Z-EN-INT

www.eaton.eu

Rapid Link

T2

M3∼
ϑ

W
V
7

3

8

6
4

PE
5

①

3
4
5



1

1

1

U

7

2

L2
L1
1
2

T1

3

PE

②

PE

6

4
5


3

PE
L3

B2

5

8

1

+24 V
< 160 m A

1

ASi+

2

(0 V)

2

3

0V

4

ASi- (+24 V)

I3

3

1

3

(2)

2

3

1

(4)

I4

1

2

3

3

③

O3
+24 V
≤1A

4

Block diagram DOL starter RAMO-D

168

Rapid Link 4.0
Connection examples

4
4
4

4

1

3
6

Optional features:
① Repair and maintenance switch RAMO-W…-C32R…
② Actuation of external brake (230 V), RAMO-Wx2…
③ Actuator output, RAMO-WA…

CA04020001Z-EN-INT

www.eaton.eu

T2

M3∼
ϑ

V
7

3

8

6
4

PE
5

1

①

4
5

2



1

3

L1

1

1

U

7

L2

2

W

T1

3

PE

PE

②

5


3

PE
L3

B1

N

4

4

B2

5

8

1

+24 V
< 160 m A

1

ASi+

2

(0 V)

2

3

0V

4

ASi- (+24 V)

I3

3

1

3

(2)

2

3

1

(4)

I4

1

2

3

3

③

O3
+24 V
≤1A

4

Block diagram RAMO-W reversing starter

Rapid Link 4.0

169

Connection examples

4
4
4

4

1

3

B1

4

Optional features:
① Repair and maintenance switch RAMO-W…-C32R…
② Actuation of external brake (400 V), RAMO-Wx4…
③ Actuator output, RAMO-WA…

CA04020001Z-EN-INT

www.eaton.eu

Rapid Link

T2

M3∼
ϑ

W
V
7

3

8

6
4

PE
5

①

3
4
5



1

1

1

U

7

2

L2
L1
1
2

T1

3

PE

②

PE

6

4
5


3

PE
L3

B2

5

8

1

+24 V
< 160 m A

1

ASi+

2

(0 V)

2

3

0V

4

ASi- (+24 V)

I3

3

1

3

(2)

2

3

1

(4)

I4

1

2

3

3

③

O3
+24 V
≤1A

4

Block diagram RAMO-W reversing starter

170

Rapid Link 4.0
Connection examples

3
4

4

2
(b)

3

2
4

4
(a)

2

1

I3(b) 0 V

3

6

Optional features:
① Repair and maintenance switch, RASP-…-C32R…
② Actuation of external brake (230 V), RASP-…xx2…
③ Device fan, RASP-…L-C32…
④ internal braking resistance, RASP-x1…

CA04020001Z-EN-INT

T2

M3∼
ϑ

V
7

3

8

6
4

PE
5

1

①

4
5

2



1

3

④

L1

1

1

U

7

L2

2

W

T1

3

PE

PE

②

5


3

PE
L3

B1

N

4

4

B2

5

8

1

+24 V
< 160 m A

1

ASi+

2

(0 V)

3

4

ASi- (+24 V)

I3a

1

3

(2)

I4(b)

3

1

(4)

I4a

1

2

③

3

M

4

F
+24 V
≤ 100 mA

0 V +24 V

RJ 45

Block diagram RASP

www.eaton.eu

Note:
Y connector RA-XM12-Y is required in order to connect 4 sensors
(I3a, I3b/I4a, I4b) (→ accessory)

Rapid Link 4.0

171

Connection examples

3
4

4

2
(b)

3

2
4

4
(a)

2

1

I3(b) 0 V

3

B1

4
6

7

3

Optional features:
① Repair and maintenance switch, RASP-…-C32R…
② Actuation of external brake (400 V), RASP-…xx4…
③ Device fan, RASP-…L-C32…
④ internal braking resistance, RASP-x1…

Note:
Y connector RA-XM12-Y is required in order to connect 4 sensors
(I3a, I3b/I4a, I4b) (→ accessory)

CA04020001Z-EN-INT

www.eaton.eu

Rapid Link

M3∼
ϑ

8

6
4

PE
5

1

①

4
5

2



1

3

④

L1

1

1

U

7

V

W

T1

3

PE

PE

②

2

L2

T2

4
5


3

PE
L3

B2

5

8

1

+24 V
< 160 m A

1

ASi+

2

(0 V)

3

4

ASi- (+24 V)

I3a

1

3

(2)

I4(b)

3

1

(4)

I4a

1

2

③

3

M

4

F
+24 V
≤ 100 mA

0 V +24 V

RJ 45

Block diagram RASP

172

Rapid Link 4.0
Motor starter RAMO, speed controller RASP

Technical data
Motor starter RAMO, speed controller RASP

RAMO-D…

RAMO-W…

RASP-2…

RASP-3…

RASP-4…

RASP-5…

General
Standards

Climatic proofing

IEC/EN 60947-4-2
IEC/EN 60947-5-1
IEC/EN 61000-6-2
IEC/EN 61000-6-4
Directive 2002/95/EG (RoHS)
CE approval
< 95%, non-condensing
IEC/EN 50178

EN 61800-5-1
EN 61800-3
Directive 2002/95/EG (RoHS)
CE approval

ρw

%

Operation

ϑ

°C

-10 - +55

-10 - +55

Storage

ϑ

°C

-30 - +70

-30 - +70

0 - +40
0 - +55 (with fan RASP-FAN-1)
-30 - +70
-30 - +70

-30 - +70

-30 - +70

III

III

III

III

III

III

4

4

2

2

2

2

Device class A

Device class A

m

10

10

2. Environment,
Class C3
5

2. Environment,
Class C3
5

2. Environment,
Class C3
5

2. Environment,
Class C3
5

g

1000 shocks per shaft, semi-sinusoidal 15 g/11 ms
IEC/EN 60068-2-27
Oscillation frequency: 10 - 150 Hz
Amplitude 0.15 mm: 6 Hz
Amplitude transition frequency on acceleration: 57 Hz
IEC/EN 60068-2-6
Vertical
Vertical
Vertical

Vertical

Vertical

Vertical

m

0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 2000 m
IP65
IP65
IP65
IEC/EN 60529
IEC/EN 60529
IEC/EN 60529

IP65
IEC/EN 60529

IP65
IEC/EN 60529

IP65
IEC/EN 60529

kg

1.6

1.7

4.2

4.2

4.2

4.4

kg

1.9

1.9

4.4

4.4

4.4

4.6

Ambient temperature

Overvoltage category
Rated impulse withstand
voltage
Radio interference level

Uimp

kV

Environment (EMC)
longest permissible length of
motor cable
Mechanical shock resistance

I

Vibration

Mounting position
Altitude

Protection type

0 - +45

Weight
without manual override
switch
with manual override switch
Main circuit
Supply
Rated operational voltage

Ue

Mains voltage (50/60Hz)

ULN

V

400 V AC
400 (-15%) - 415 (+10%)

400 V AC
380 (-15%) - 400 (+10%)

Input current

ILN

T

≤ 6.6

3.2

4

5.6

7.3

50/60

50/60

50/60

47 - 66 Hz (± 0%)

47 - 66 Hz (± 0%)

47 - 66 Hz (± 0%)

47 - 66 Hz (± 0%)

≤ 6.6

Supply frequency

fLN

Hz

AC voltage
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
50/60
50/60
50/60

Frequency range

fLN

Hz

47 - 63 Hz (± 0%)

System configuration

47 - 63 Hz (± 0%)

max. one time per minute

Mains switch-on frequency
Mains current distortion

THD

%

-

-

> 120

> 120

> 120

> 120

Rated conditional shortcircuit current
Short-circuit protective
device

Iq

kA

< 10

< 10

<5

<5

<5

<5

CA04020001Z-EN-INT

Type 1 coordination via the power bus' feeder unit

www.eaton.eu

Rapid Link 4.0

173

Motor starter RAMO, speed controller RASP

RAMO-D…

RAMO-W…

RASP-2…

RASP-3…

RASP-4…

DOL starter with
thyristors and
bypass contacts,
2-phase

Frequency inverter with internal DC link and IGBT inverter

RASP-5…

Power section
Function

On-delay

tON

ms

20 - 35

Reversing starter
with relays,
thyristors and
bypass contacts,
2-phase
controlled
20 - 35

30 - 50

30 - 50

30 - 50

30 - 50

Off-delay

tOFF

ms

20 - 35

20 - 35

15 - 35

15 - 35

15 - 35

15 - 35

Lifespan, mechanical

Operat
ions
Operat
ions

AC3: > 10.000.000

AC3: > 10.000.000

-

-

-

-

AC3: > 10.000.000

AC3: > 10.000.000

-

-

-

-

Lifespan, electrical
Overload cycle

AC-53a

AC-53a

-

-

-

-

Overload current for 60 s
every 600 s
Starting current for 2 s

IL

A

-

-

3.6 (at 40 °C)

5 (at 40 °C)

6.5 (at 40 °C)

8.4 (at 40 °C)

IL

A

-

-

4.8 (at 40 °C)

6.6 (at 40 °C)

8.6 (at 40 °C)

11.2 (at 40 °C)

Output voltage with Ve

U2

= ULN

= ULN

0 - ULN

0 - ULN

0 - ULN

0 - ULN

Output Frequency

f2

Hz

= fLN

= fLN

0 - 50 Hz (max. 320 Hz)

Switching frequency

fPWM

kHz

-

-

-

-

6
(adjustable 1.5 - 16)
linear, parameterizable

Δf

Hz

-

-

0.01

0.01

0.01

0.01

Ie

A

6.6

6.6

2.4

3.3

4.3

5.6

-

0.3 - 6.6
adjustable
-

Rated operational current at an operating frequency of 6 kHz and an ambient
air temperature of +40 °C
0.48 - 4.8
0.66 - 6.6
0.86 - 8.6
1.12 - 11.2
adjustable
adjustable
adjustable
adjustable
0.95
0.95
0.96
0.96

Operation Mode
Frequency resolution
(setpoint value)
Rated operational current
Note
Motor current limit

I

A

Efficiency

η

%

0.3 - 6.6
adjustable
-

Maximum leakage current to
ground (PE) without motor
Fan

IPE

mA

-

-

3.5

-

-

internal, temperature controlled
optional RASP-FAN-S1 on heat sink, temperaturecontrolled

3.5

3.5

3.5
internal and on
heat sink,
temperaturecontrolled

Motor feeder
Assigned motor rating

at 400 V, 50 Hz
Actuator for external motor
brake
Breaking voltage
Braking current

P

A

U

V

for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz
or 1800 min-1 at 60 Hz
-

230 V AC -15% / +10%
400 V AC -15% / +10%
≤ 0.6 A
≤ 0.6 A
(max. 6 A for
(max. 6 A for
120 ms)
120 ms)

230 V AC -15% / +10%
400 V AC -15% / +10%
≤ 0.6 A
≤ 0.6 A
(max. 6 A for
(max. 6 A for
120 ms)
120 ms)

≤ 0.6 A
(max. 6 A for
120 ms)

≤ 0.6 A
(max. 6 A for
120 ms)

I

A

Braking torque

%

I/Ie

-

-

≦ 30

≦ 30

≦ 30

≦ 30

Switch-on threshold for
the braking transistor
DC braking

UDC

V

-

-

765 V DC

765 V DC

765 V DC

765 V DC

%

I/Ie

-

-

≦ 100, adjustable

Uc

V

24 V DC - 15 % / + 20 % via AS-Interface® plug

Braking function

Control section
External control voltage
AS-Interface®
RAMO-…AI1…
RASP…
RAMO-…AI2…

max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Specification: S-7.4
Number of slave addresses: 31
Specification: S-7.A.E.
Number of slave addresses: 62

Specification: S-7.4
Number of slave addresses: 31
-

CA04020001Z-EN-INT

www.eaton.eu

Rapid Link

Note

174

Rapid Link 4.0

Rapid Link 4.0

Accessories

175

Accessories

Accessories

Flat cable

Distributor module

Distributor module

Flexible busbar junction 400 V AC/24 V
DC
RA-C1-PLF

Round cable junction

Round cable junction

RA-C1-7X4HF

RA-C1-AM-7

RA-C1-VM-7

RA-C2-S1-4

RA-C4-PB65

Standards

IEC 60332-1
DIN VDE 0295 Class 6
DIN VDE 0281 Part 404

Protection type

IP65
IEC/EN 60529
As required

DIN/EN 60664-1
DIN/EN 60529
DIN/EN 60999
DIN VDE 0470 Part 1
IP65
IEC/EN 60529
As required

IEC/EN 60047-7-1
DIN VDE 0470 Part 1

IEC/EN 68000-2-27
IEC/EN 60998-3
DIN VDE 0660 Part 1535

EN 61684
DIN VDE 0110
DESINA

-

IP65
IEC/EN 60529
As required

IP65
IEC/EN 60529
As required

IP65
IEC/EN 60529
As required

IP65
IEC/EN 60529
As required

General

Mounting position
Ambient temperature
Operation

ϑ

°C

-15 - +50

-15 - +40

-15 - +50

-15 - +50

-15 - +50

-40 - +55

Storage

ϑ

°C

-5 - +70

-5 - +50

-5 - +50

-5 - +50

-5 - +50

-10 - +40

Flame retardance, fire propagation

Self-extinguishing to IEC 60332-1

-

-

-

-

-

Resistance to oils and acids

To VDE 0473, Part 811-2-1

-

-

-

-

-

Sheathing

-

-

-

-

-

Minimum bending radius

mm

Material according to DIN VDE 0282, EVA
mixture EM4, black
18

-

-

-

-

-

Cable weight

kg/km

440

-

-

-

-

-

Outer dimensions L x W x H

mm

L x 34.8 x 6.0

160 x 60.2 x 59.5

175 x 83 x 78

119 x 57.5 x H

158 x 112.5 x 55

181 x 104 x 67

Overvoltage category

-

III

III

III

III

III

Pollution degree

-

3

3

3

3

3

Termination

-

Springloaded terminals 1.5 to 4 mm²

Twin-level terminal block, 1.5 to 4 mm²

IDC termination

Piercing/screw terminals

Insulation piercing terminals

-

V-M25: 9 - 17
V-M20: 6 - 13

9 - 17

-

10 - 13
13 - 16

11 - 13
13 - 15
15 - 17

Outer cable diameter

mm

Main circuit
Rated operational voltage

Ue

Rated operational current

Ie

Line protection

500 V AC

500 V AC

500 V AC

500 V AC

500 V AC

690 V AC

A

25

25

25

-

20/25 (2.5 mm2/4 mm2)

25 (4 mm2)

Type

PKE32/XTU-32
PKZM0-25
FAZ-C25/3

PKE32/XTU-32
PKZM0-25
FAZ-C25/3

PKE32/XTU-32
PKZM0-25
FAZ-C25/3

PKE32/XTU-32
PKZM0-25
FAZ-C25/3

PKE32/XTU-32
PKZM0-25
FAZ-C25/3

PKE32/XTU-32
PKZM0-25
FAZ-C25/3

Rated operational voltage

Ue

V

24 V DC

24 V DC

24 V DC

24 V DC

24 V DC

-

Rated operational current

Ie

A

25

10

25

-

20/25 (2.5 mm2/4 mm2)

-

Rapid Link

Control circuit

Dimensions
Motor cable and motor feeder plug
RAMO-CM1-2M0 /-5MO /-10MO

Motor cable and motor feeder plug
RASP-CM1-2M0 /-5MO

EN 61684
DIN VDE 0110
IP65
IEC/EN 60529

EN 61684
DIN VDE 0110
IP65
IEC/EN 60529

Motor starter RAMO
without manual override switch

with manual override switch

Protection type

145

Standards

120

General



Ambient temperature
Operation

ϑ

°C

-30 - +70

-30 - +70

Terminal capacities

mm2

8 x 1.5

4 x 1.5 + 2 x (2 x 0.75) screened

Outer cable diameter

mm

9 - 13

9 - 13

Minimum bending radius

mm

6 x outer cable diameter

10 x outer cable diameter

Conductor material

-

-

Material
Colour

Outer casing halogen free
Cable: Cu flexible to VDE 0295 Class 5
Silver grey (RAL 7001)

Outer casing halogen free
Cable: Cu flexible to VDE 0295 Class 6
Orange (RAL 2003)

Resistance to oils and acids

VDE 0472 Part 803 B

VDE 0472 Part 803 A/B

Flame retardance, fire propagation

EN 50265-2-1

IEC 60332-2

Contact pins: 8 x 1.5

Contact pins: 4 x 1.5 + 4 x 0.75

Contacts

Polycarbonate

Polycarbonate

Contact material

Cu silver-plated

Cu silver-plated

Housing

Polycarbonate

Polycarbonate

Locking facility

Polyamide

Polyamide



Connection cable

II

I

0

245
285

245
270

Metal housing with plug-in connection
mm2

Conductor cross-section

II

I

0

Material

CA04020001Z-EN-INT

www.eaton.eu

173
220

⌀ 6.2
173
220

⌀ 6.2

CA04020001Z-EN-INT

www.eaton.eu

176

Rapid Link 4.0
RASP speed controllers

RASP speed controllers

RASP speed controllers

Device fans RASP-FAN-S1
with fan

without manual override switch

without manual override switch

157

195

45

without fan

190





0
I

II

146
0

245
270

245
270

I

II

173
220

⌀ 6.2
173
220

with manual override switch

220

182

with manual override switch

⌀ 6.2





II

I

0

245
285

245
285

II

I

0

173
220

CA04020001Z-EN-INT

⌀ 6.2
173
220

www.eaton.eu

⌀ 6.2

Rapid Link 4.0

177

Accessories
Accessories

Accessories
flexible busbar junction

Locking brackets

RA-C1-PLF
RA-C1-PLF1

SET-M-LOCK

35

o 8.5

57.5

M5

65

50

119

M4

47.5

35

109

Distributor module

59.5

6.5

5

70

37.2

36.7

4.5

83

RA-C1-VM-7

60.2

RA-C1-AM-7

160

162.5

3.3

175

78

48.2

RA-C1-VP-AM-2

47.5

55

6.5

M4

4.5

132

107

6

115

54.5

Round cable junction

27

25.5

55

RA-C2-S1-4

78.5
112.5

5.5

158

Rapid Link

130

142.5

Locking brackets

89
7

104

RA-C4-PB65

165
181

6
67

CA04020001Z-EN-INT

www.eaton.eu

®

SmartWire-DT™ – Cost-optimized communication for switchgear
Manufacturers of machines and systems strive to achieve a balance between the
maximum level of functionality and cost optimization. Designed for further development, SmartWire-DT is a communication system for industrial switchgear in control
panels and the periphery: from control, protection and switching to actuation, operation
and monitoring. One technology from which you will profit, now and in the future.

Taxes

Contactors

Switching

Operation &
monitoring

Driving

PowerXL variable frequency drives and DS7 soft starters – Communicate with SmartWire-DT
Being able to use a controller to directly access all of a soft starter's and/or variable frequency
drive's parameters via SmartWire-DT is the epitome of ease of operation. Users can read and
overwrite potentiometer settings. Extended status, error, and diagnostic messages can be retrieved directly. The result: absolute data transparency. The plug-in units make installation fast
and foolproof, and the resulting connection includes the soft starter's control current supply.
SmartWire-DT modules for expanding the functionality of the variable frequency drives in the
DC1 and DA1 series are scheduled to hit the market soon. This will enable users to communicate with their variable frequency drives via SmartWire-DT on the basis of the relevant Profidrive profile. Other profiles will also be available for simple applications. Another important function that will complement the ability to change parameters in variable frequency drives will be
the ability to use extended diagnostic functions. Within this context, function blocks will make
it easy to connect to Eaton PLCs and HMIs.

SmartWire-DT™

179

SmartWire-DT
System overview

180

Ordering
SmartWire-DT Gateways

182

SmartWire-DT accessories

182

Technical Data
SmartWire-DT Gateways

184

SmartWire-DT accessories

186

Dimensions
188

SmartWire-DT accessories

188

SmartWire-DT®

SmartWire-DT Gateways

CA04020001Z-EN-INT

www.eaton.eu

180

SmartWire-DT®
Moeller® series

System overview

4
5

3
5

5

2
2

1

8

4

12

9

5

11

7
10

6
6
6

6

5

6

10

13
4

14
25

16

15

17

18

12

21
22

11

23

20

19
4

5

10

20

10
6

4

6
6
6
6

CA04020001Z-EN-INT

www.eaton.eu

24

SmartWire-DT®

181

System overview

Moeller® series
1

SmartWire-DT HMI-PLC
→ Industrial Switchgear 2011 catalog

SmartWire-DT module for variable
frequency drives

10

→ page 33

Data plug Sub-D 9 pole

SmartWire-DT adapter for flat/round
cable for top-hat rail mounting

19

→ page 183

2

DC1 variable frequency drive
SmartWire-DT Gateways

3

→ page 12

4

→ page 20

11

DA1 variable frequency drives

5

SmartWire-DT flat ribbon cable 8 pole

12
21

Motor-protective circuit-breaker
PKE12, PKE32

→ page 182

→ page 182

20

→ Industrial Switchgear 2011 catalog

→ page 182

SmartWire-DT blade terminal 8 pole

SmartWire-DT PKE (motor-protective
circuit-breaker)

SmartWire-DT universal module,
front mount

13

→ Industrial Switchgear 2011 catalog

Soft starter DS7 < 32 A

→ page 183

22

→ page 111

SmartWire-DT external device plug
8 pole

6

SmartWire-DT control panel cable
entry for flat to round cable

14

Soft starter DS7 > 32 A

→ page 183

→ page 182

SmartWire-DT PKE module
(motor starter)

7

23

→ page 111

SmartWire-DT plug connector

15

→ page 183

SmartWire-DT bus termination resistor
for 8-pole flat band conductor

24

→ page 183

→ Industrial Switchgear 2011 catalog

Motor starter with PKE electronic motor
protection

8

RMQ-Titan surface-mounting
enclosure with RMQ-Titan elements

16

SmartWire-DT planning and ordering
aid, SWD-Assist

→ Industrial Switchgear 2011 catalog

25

→ Industrial Switchgear 2011 catalog

SmartWire-DT plug connector
Soft starter DS7 with electronic motor
protection from PKE
→ Industrial Switchgear 2011 catalog

9

17

→ page 183

SmartWire-DT round cable, 8-pole

18

→ page 183

System overview

Note: You can find the entire SmartWire-DT range of products by consulting our industrial main catalog or our online catalog at http://ecat.moeller.net

Features
SmartWire-DT Gateways
• Connection of SmartWire-DT to
field bus.
• Field bus address setting with dip
switches
• Automatic baud rate detection
• Feeding the supply voltage for the
SmartWire-DT modules
• Supplies the control voltage for the
motor starter or contactor
• Configuration button for automatic
addressing of the SmartWire-DT
module.
• Support of up to 99 SmartWire-DT
modules.

SmartWire-DT module
• Function element for connecting to
RMQ-Titan pilot devices.
• Function element for connecting to
DLM contactors
• Function element for connecting to
PKZ/PKE motor-protective circuitbreakers
• Function module for connecting to
NZM2,3,4 circuit-breakers
• Connection of digital and analog
input/output modules
• DS7 Soft starter connection
• Function element for connecting to
PowerXL™ DC1, DA1 variable
frequency drives

SmartWire-DT Assist (SWD-Assist)
• Easy creation of SmartWire-DT
networks
• Integrated validity check
• Generation of ordering lists.
• Online-Functionality
– Simple pre-commissioning
– Configuration check and
comparison
– Display of parameters and
diagnostics
– Easy diagnostics of
SmartWire-DT module
• Free download under:
http://downloadcenter.moeller.net
SmartWire-DT®

SmartWire-DT HMI-PLC
• with SmartWire-DT master
interface and PLC function
• Compact design with light plastic
enclosures
• Wide selection of onboard
interfaces
• 3.5” , 5.7” or 7” TFT-LCD screen

CA04020001Z-EN-INT

www.eaton.eu

182

SmartWire-DT®
Gateways, accessories

Moeller® series

Ordering
Gateways, accessories

Description

Baud Rates

Number of
SmartWireDT slaves

Part no.
Article no.

Max. 58

EU5C-SWD-DP
116308

Price
see
price list

Std. pack

Information relevant for export to North
America

1 off

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

SmartWire-DT Gateways
supply of the SmartWire-DT modules and switchgear
For connection to
PROFIBUS-DP field bus
field bus connection
through 9-pin SUB-D
socket
Separate RS232 diagnostics
interface (RJ45)
For connection to
CANopen® field bus
Field bus connection
through 9-pin SUB-D plug
Separate RS232 diagnostics
interface (RJ45)
For connection to the
Ethernet-IP/MODBUS-TCP
field bus
Field bus connection via
Ethernet Switch
Separate RS232 diagnostics
interface (RJ45)
for connection to field bus
PROFINET as PROFINET IODevice
Field bus connection via
Ethernet Switch
Separate USB diagnostics
interface (Mini-USB)

up to 12 MBit/
s

up to 1 MBit/s

Max. 99

EU5C-SWD-CAN
116307

10/100 MBit/s

Max. 99

EU5C-SWD-EIPMODTCP
153163

100 MBit/s

Max. 99

EU5C-SWDPROFINET
170124

1off

UL File No.
UL Category
Control No.
CSA File No.
North America
Certification

E29184
NKCR
2324643
3211-07
UL listed, CSA certified

E221530
NRQA
UL report applies to
both US and Canada
UL listed, CSA certified

Flat band conductor, 8 pole
For connecting the SmartWire-DT modules within the control panel
8 pole
not ready-assembled
Length
100 m
not ready-assembled
Length
3m
Length
5m
Length
10 m
SWD4-8SF2

SWD4-8SF2 SWD4-8S

SWD4-100LF8-24
116026
SWD4-3LF8-24-2S
116027
SWD4-5LF8-24-2S
116028
SWD4-10LF8-242S
116029

1 off

SWD4-8SF2-5
116022

10 off

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

E29184
NKCR
2324643
3211-07
UL listed, CSA certified

External device plugs
For connecting the ribbon cable to SmartWire-DT modules

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

E29184
NKCR
2324643
3211-07
UL listed, CSA certified

Link
For bridging open mounting locations for external device
plugs
Front fixing

SWD4-SEL8-10
116021

5 off

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

E29184
NKCR
2324643
3211-07
UL listed, CSA certified

Blade terminal
For connecting the ribbon cable to the gateway, power
feeder module, coupling, bus termination resistor

SWD4-8MF2
116023

10 off

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

E29184
NKCR
2324643
3211-07
UL listed, CSA certified

Coupling
Coupling blade terminal 8-pole
SWD4-8SFF2
-5
+ 15V

CA04020001Z-EN-INT

www.eaton.eu

SWD4-8SFF2-5
116024

1 off

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

E29184
NKCR
2324643
3211-07
UL listed, CSA certified

SmartWire-DT®

183

Accessories

Moeller® series
Accessories

Description

Part no.
Article no.

For connecting each SmartWire-DT line

SWD4-RC8-10
116020

Price
see price
list

Std. pack

Information relevant for export to
North America

1 off

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

Network terminator
SWD4-RC810
+ 15V

E29184
NKCR
2324643
3211-07
UL listed, CSA
certified

Cable adapters
1

2

3

4

5

6

7

8

for connection flat cable (plug) on round cable
(terminal)

SWD4-8FRF-10
121377

1 off

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

E29184
NKCR
2324643
3211-07
UL listed, CSA
certified

+15 V

Switch cabinet bushing
for transition from SmartWire-DT ribbon cable to round cable
Connection of ribbon cable with blade terminal SWD4-8MF2
8 pole
double conductor run pluggable
Additional control voltage feeder for the motor starter and contactors.
Connection round cable via socket
Connection round cable via plug

SWD4-SFL8-20
121380
SWD4-SML8-20
121381

1 off
1 off

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

E29184
NKCR
2324643
3211-07
UL listed, CSA
certified

Round conductor
For laying the SmartWire-DT network outside of the control panel.
For connecting the SmartWire-DT module outside
the control panel
8 pole
HK-S0-Li2YY, 8 mm diameter
Length 50 m

SWD4-50LR8-24
116030

1 off

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

E29184
NKCR
2324643
3211-07
UL listed, CSA
certified

Connectors for SWD round conductors
8 pole socket
Straight
8-pinplug connector
Straight
8 pole socket
90° angled
8-pinplug connector
90° angled

SWD4-SF8-67
116033
SWD4-SM8-67
116034
SWD4-SF8-67W
116035
SWD4-SM8-67W
116036

1 off

Pliers for connecting external device plug and
ribbon cable
Pliers for making contacts with blade terminals and
ribbon cables

SWD4-CRP-1
116025
SWD4-CRP-2
116699

1 off

UL/CSA certification not required

M22-SWD-NOP
147637

20 off

North America
Certification

UL File No.
UL Category
Control No.
CSA File No.
CSA Class No.
North America
Certification

E29184
NKCR
2324643
3211-07
UL listed, CSA
certified

Tools for plugs

for configured but not yet installed SmartWire-DT slaves
Front mount
Configuration
1

4

3

6

2

5

CA04020001Z-EN-INT

Request filed for UL
and CSA

www.eaton.eu

SmartWire-DT®

Universal slave

184

SmartWire-DT®
Gateways

Technical data
Gateways

EU5C-SWD-DP

EU5C-SWD-CAN

EU5C-SWD-EIP-MODTCP

General
Standards
Dimensions (W x H x D)

mm

IEC/EN 61131-2
EN 50178
35 x 90 x 127

Weight

kg

0.16

35 x 90 x 124
0.16

Mounting

Top-hat rail IEC/EN 60715, 35 mm

Mounting position

As required

0.17

Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)

IP20

IP20

IP20

Vibrations (IEC/EN 61131-2:2008)
Constant amplitude 3,5 mm

Hz

5 - 8.4

5 - 8.4

5 - 8.4

Constant acceleration 1 g

Hz

8.4 - 150

8.4 - 150

8.4 - 150

Impacts

9

9

9

mm

50

50

50

m

0.3

0.3

0.3

Overvoltage category

II

II

II

Pollution degree

2

2

2

Mechanical shock resistance (IEC/EN 60068-2-27)
semi-sinusoidal 15 g/11 ms
Drop to IEC/EN 60068-2-31

Fallhöhe

Free fall, packaged (IEC/EN 60068-2-32)
Electromagnetic compatibility (EMC)

Electrostatic discharge (IEC/EN 61131-2:2008)
Air discharge (Level 3)

kV

8

8

8

Contact discharge (Level 2)

kV

4

4

4

Electromagnetic fields (IEC/EN 61131-2:2008)
80 - 1000 MHz

V/m

10

10

10

1.4 - 2 GHz

V/m

3

3

3

2 - 2.7 GHz

V/m

1

1

1

Radio interference suppression (SmartWire-DT)

EN 55011 Class A

Burst (IEC/EN 61131-2:2008, Level 3)
Supply cables

kV

2

2

2

CAN/DP bus cable

kV

1

1

1

SmartWire-DT cables

kV

1

1

1

Surge (IEC/EN 61131-2:2008, Level 1)
Supply cables/CAN/DP bus cable

Supply cables 0.5 kV, CAN/DP bus cable 1 kV

Radiated RFI (IEC/EN 61131-2:2008, Level 3)

V

10

10

10

°C

- 25 - + 55

- 25 - + 55

- 25 - + 55

Climatic environmental conditions
Operating ambient temperature (IEC 60068-2)

Take appropriate measures to prevent condensation

Condensation
Storage

°C

- 40 - + 70

- 40 - + 70

- 40 - + 70

relative humidity, non-condensing (IEC/EN 60068-2-30)

%

5 - 95

5 - 95

5 - 95

Rated operational voltage

V

24 V DC (-15/+20%)

Residual ripple on the input voltage

%

≦5

≦5

≦5

Yes

Yes

Yes

3

3

3

Supply voltage UAux

Protection against polarity reversal
Max. current

Imax

A

If contactors with a total power consumption > 3 A are connected, a power feeder
module EU5C-SWD-PF1/2 has to be used.
no, external fuse FAZ Z3

Short-circuit rating
Power loss

W

Potential isolation
Rated operating voltage of 24-V-DC slaves

CA04020001Z-EN-INT

www.eaton.eu

V

Normally 1

Normally 1

Normally 1

No

No

No

typ. UAux - 0.2

typ. UAux - 0.2

typ. UAux - 0.2

SmartWire-DT®

185

Gateways

EU5C-SWD-DP

EU5C-SWD-CAN

EU5C-SWD-EIP-MODTCP

Supply voltage UPow
Supply voltage

V

24 DC -15 % + 20 %

24 DC -15 % + 20 %

24 DC -15 % + 20 %

Input voltage ripple

%

≦ 5

≦ 5

≦ 5

yes

yes

yes

0.7

0.7

0.7

yes

yes

yes

Siemens MPI, (optional)
Rated current

I

A

Overload proof
Inrush current and duration

A

12.5 A/6 ms

12.5 A/6 ms

12.5 A/6 ms

Heat dissipation at 24 V DC

W

3.8

3.8

3.8

No

No

No

Potential isolation between UPow and 15 V SmartWire-DT
supply voltage
Bridging voltage dips

ms

10

10

10

Repetition rate

s

1

1

1

Status indication

LED

yes

yes

yes

SmartWire-DT supply voltage
Rated operating voltage

Ue

V

14,5 ± 3 %

14,5 ± 3 %

14,5 ± 3 %

max. current

Imax

A

0.7

0.7

0.7

If SmartWire-DT modules with a total power consumption > 0.7 A are connected,
a power feeder module EU5C-SWD-PF2 has to be used.
Yes
Yes
Yes

Short-circuit rating
Connection supply and inputs/outputs
Connection type

Push in terminals

Solid

mm2

0.2 - 1.5

0.2 - 1.5

0.2 - 1.5

Flexible with ferrule

mm2

0.25 - 1.5

0.25 - 1.5

0.25 - 1.5

UL/CSA solid or stranded

AWG

24 - 16

24 - 16

24 - 16

SmartWire-DT network
Station type

SmartWire-DT master
58

99

99

kBd

125
250
automatic

125
250
automatic

125
250
automatic

LED

Connection SmartWire-DT

SmartWire-DT master LED: green
Configurations LED: red
Plug, 8-pole

Plug connectors

Blade terminal SWD4-8MF2

Number of SmartWire-DT slaves
Baud Rates
Address allocation
Status indication

Function

PROFIBUS DP slave

CANopen® slave

Input data, max.

Byte

240

128

Output data, max.

Byte

240

128

Baud Rates

up to 12 MBit/s

up to 1 MBit/s

Ethernet IP/MODBUSTCP Slave
Ethernet IP/MODBUSTCP
Ethernet-IP: 546
MODBUS-TCP: 800
Ethernet-IP: 496
MODBUS-TCP: 642
10/100 MBit/s

Protocol

PROFIBUS-DP

CANopen®

Baud rates switching

automatic

automatic

automatic

Address

2 … 125

2 … 32

-

Address allocation

DIP switch

DIP switch

Two-coloured red/green

Two-coloured red/green

Terminating resistor

switchable via plug

DIP switches

Dip switch/DHCP/
BOOTP
Selection via DIP switch
Link status: yellow
(10 MBit), green
(100 MBit) flashing
-

Terminal type

1 x D-SUB socket, 9-pin

1 x D-SUB socket, 9-pin

Potential isolation

Yes

Yes

Status display interface

LED

2 x RJ45 (2-channel
switch)
Yes

CA04020001Z-EN-INT

www.eaton.eu

SmartWire-DT®

Fieldbus interface

186

SmartWire-DT®

SmartWire-DT®

Accessories

187

Accessories

Accessories

Part no.

M22-SWD-NOP...

SWD4-RC8-10

SWD4-8SF2-5

SWD4-8SFF2-5

SWD4-8FRF-10

SWD4-SFL8-20

SWD4-SML8-20

IEC/EN 61131-2
EN 50178
48.5 x 34.5 x 10

IEC/EN 61131-2
EN 50178
15 x 36.5 x 17.5

IEC/EN 61131-2
EN 50178
48.5 x 34.5 x 10

IEC/EN 61131-2
EN 50178
35 x 90 x 35

IEC/EN 61131-2
EN 50178
35 x 83 x 40

IEC/EN 61131-2
EN 50178
35 x 83 x 46

General
Standards
Dimensions (W x H x D)

mm

IEC/EN 61131-2
EN 50178
12 x 42 x 39

Weight

kg

-

-

-

-

-

-

-

Weight

g

10

10

5.5

4.5

42

50

50

As required

As required

As required

As required

As required

As required

As required

IP20

IP20

IP20

IP20

IP20

IP67

IP67

Mounting position
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
Vibrations (IEC/EN 61131-2:2008)
Constant amplitude 3,5 mm

Hz

5 - 8.4

5 - 8.4

5 - 8.4

5 - 8.4

5 - 8.4

5 - 8.4

5 - 8.4

Constant acceleration 1 g

Hz

8.4 - 150

8.4 - 150

8.4 - 150

8.4 - 150

8.4 - 150

8.4 - 150

8.4 - 150

Impacts

9

9

9

9

9

9

9

mm

50

50

-

-

-

-

-

m

0.3

0.3

-

-

-

-

-

Overvoltage category

Not applicable

II

-

-

-

-

-

Pollution degree

2

2

-

-

-

-

-

Mechanical shock resistance (IEC/EN 60068-2-27)
semi-sinusoidal 15 g/11 ms
Drop to IEC/EN 60068-2-31

Fallhöhe

Free fall, packaged (IEC/EN 60068-2-32)
Electromagnetic compatibility (EMC)

Electrostatic discharge (IEC/EN 61131-2:2008)
Air discharge (Level 3)

kV

8

8

-

8

8

8

8

Contact discharge (Level 2)

kV

4

4

-

4

4

4

4

Electromagnetic fields (IEC/EN 61131-2:2008)
80 - 1000 MHz

V/m

10

10

-

-

-

10

10

1.4 - 2 GHz

V/m

3

3

-

-

-

3

3

2 - 2.7 GHz

V/m

1

1

-

-

-

1

1

EN 55011 Class A

EN 55011 Class A

-

-

-

-

-

Radio interference suppression (SmartWire-DT)
Burst (IEC/EN 61131-2:2008, Level 3)
Supply cables

kV

2

-

-

-

SmartWire-DT cables

kV

1

1

-

-

-

-

-

V

10

10

-

-

-

10

10

°C

- 30 - + 55

- 25 - + 55

- 25 - + 55

- 25 - + 55

- 25 - + 55

- 25 - + 55

- 25 - + 55

Storage

°C

Take appropriate
measures to prevent
condensation
- 40 - 80

Take appropriate
measures to prevent
condensation
- 40 - 70

Take appropriate
measures to prevent
condensation
- 40 - 70

Take appropriate
measures to prevent
condensation
- 40 - 70

Take appropriate
measures to prevent
condensation
- 40 - 70

Take appropriate
measures to prevent
condensation
- 40 - 70

Take appropriate
measures to prevent
condensation
- 40 - 70

relative humidity, non-condensing (IEC/EN 60068-2-30)

%

5 - 95

5 - 95

5 - 95

5 - 95

5 - 95

5 - 95

5 - 95

Radiated RFI (IEC/EN 61131-2:2008, Level 3)
Climatic environmental conditions
Operating ambient temperature (IEC 60068-2)
Condensation

SmartWire-DT network
Station type

SmartWire-DT slave

-

-

-

-

-

-

Number

-

-

-

-

-

-

-

Baud rate setting

automatic

-

-

-

-

-

-

Green

-

-

-

-

-

-

Connections

Plug, 8-pole

-

-

-

-

-

-

Plug connectors

SWD4-8SF2-5

-

-

-

-

-

-

Number of insertion cycles

≥ 50

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

SmartWire-DT status LED

LED

Contacts
Lifespan mechanical/electrical
LED display

Operations

No

-

-

-

-

-

-

Diagnostics

LED

Yes

-

-

-

-

-

-

Fixing

Front fixing

-

-

-

-

-

-

SmartWire-DT®

Function element

Connection options
SWD-In

Plug, 8-pole

Plug connector

Plug, 8-pole

Plug, 8-pole

Plug, 8-pole

Plug, 8-pole

Number of insertion cycles

≥ 200

≥1

≥ 200

≥ 200

≥ 200

≥ 500

SWD-Out

-

Socket, 8-pole

Plug, 8-pole

Push in terminals

Socket, 8-pole

Plug, 8-pole

Number of insertion cycles

-

≥ 200

≥ 200

-

≥ 500

≥ 200

CA04020001Z-EN-INT

www.eaton.eu

CA04020001Z-EN-INT

www.eaton.eu

188

SmartWire-DT®
Gateways, accessories

Dimensions
Gateways, accessories

90

SmartWire-DT Gateways

EU5C-SWD-DP
EU5C-SWD-CAN
EU5E-SWD-...
EU5C-SWD-PF...
EU5C-SWD-EIP-MODTCP...
EU5C-SWD-PROFINET
NZM-XSWD-704...

a
122
122
97
120
120
120
97

b
90
90
90
90
90
90

35

4.5
a

Network terminator

Coupling

SWD4-8SF2-5

SWD4-RC8-10

SWD4-8SFF2-5

14.9

48.4

36.4

4

4

30

48.4

12.8

17.2

External device plugs

25.9

25.9

10.15

10.15

34.3

34.3

Adapter flat cable on round cable

SWD4-SFL8-20

SWD4-8FRF-10

4

14

14

M18 x 0.75

Switch cabinet bushing socket

SWD4-SM8-20
M18 x 0.75

Switch cabinet bushing plug

21

35

21

35

90

82.4

82.4

4

35

23.2
36

Plug connectors for SmartWire-DT round cables, flat

SWD4-SF8-67W

SWD4-SF8-67
o 18

37.1

37.4

o 18

SWD4-SM8-67W

o 18.5

Connectors for SmartWire-DT round cables, angled

45

20

20

o 18.5

SWD4-SM8-67

44.5

30.8

30.8

55

54

CA04020001Z-EN-INT

www.eaton.eu

M16 x 0.75

M16 x 0.75

M16 x 0.75

Planning safety and process
optimization – CAD data at the
click of a mouse!
• 9,500 article data items
and macros
• Convenient selection tool
• Version P8

Eaton is providing its customers with CAD data to offer optimum support during planning. Both electrical and mechanical design data can be called up quickly and conveniently from the Internet at any time. This reduces processing times, minimizes errors
and thus reduces costs already in the engineering phase of control panels, systems and
machinery.
eCAD: Eaton makes product data and macros available for the EPLAN planning system and
the Electric P8 version. Device data for over 9,500 products can be downloaded from the
Eaton website and integrated in customer article databases using a specially developed selector.

• Models for approx.
10,000 products
• 70 different neutral &
native formats

URL
www.moeller.net/cad

mCAD: Eaton makes 2D and 3D data available for more than 10,000 products. Over 70 different neutral and native formats guarantee compatibility with the project engineering systems
of the customer. The models can either be integrated directly into the planning software from
the Partcommunity Portal on the Internet or via the CADENAS Partsolution software.

Worldwide export of machines
and plants
European machine and system building and worldwide exports are
closely related. Even if you don't export your machines at present,
you should be prepared for it in the future. Eaton provides switchgear
and protective devices with all the essential approvals and certificates
for machine and system building. In most countries around the world,
conformity with international standards is the sole requirement for
successful exports. This is because components in these locations
are governed by compliance with well known and established IEC
standards. In this respect, the European CE mark is not only the
passport for exports within Europe but also far beyond its borders.

World market equipment for machine building
Nearly all the switchgear and protective devices of Eaton's Moeller® series
are world market devices. Each product line thus carries all the approvals and
certification marks required for worldwide use.
These product lines include those for
• Pilot devices, limit switches
• Contactors and various timing and special relays
• Motor-protective circuit-breakers and relays
• Electronic components and systems.
With circuit-breakers and switch-disconnectors, Eaton offers IEC devices for
use in most countries in the world and NA devices with virtually the same
dimensions and the same accessories for the North American market. This
considerably simplifies device selection since the North American standards
often involve the need for considerably different technical specifications.

Electrical engineering products and their applications are not harmonized
internationally.

The greatest differences to the IEC world are in North America, i.e. the USA and Canada. For many newcomers to the
export business, it is initially surprising to experience the very
different approaches and solutions.
Special components, such as handles for main switches
that can only be operated by the intentional switching of an

additional handle when the control panel door is opened, may
sometimes be required for export to North America. Likewise, the European motor-protective circuit-breaker is only
accepted with an upstream protective device or with larger
air and creepage distances at the incoming terminals. Eaton
is the competent partner of choice for export-related issues
here.

Qualified information is a critical key to success
The Eaton Main Catalogue for Moeller® series products provides reliable
information for machine and panel builders on the approval of components deployed for North American market. Each selection page provides
information such as the relevant product standard, the E-File Number, the
Category Control Number or the CSA Class Number. Many customers
incorporate this information in their parts lists in order to be well prepared
for the acceptance procedures.
Up to 13 data items are listed here for
each product, such as the suitability for
use in feeders or branch circuits, the
maximum operating voltage, or the North
American degree of protection, such as
UL / CSA Type 4X. The Main Catalogue
also contains a glossary with explanations
of the American terms.

The link http://www.moeller.net/eaton-approbationen/en/index.jsp shows
the relevant approvals or permits for each component type. This therefore
enables you to view the certificates provided or, depending on the test
authority, also the product report. The information given is the same as
what is provided in the databases of the authorities.

Switchgear for USA and Canada
Moeller® series

www.eaton.com/moellerproducts

Product selection for
North American exports
made easy

Main Switch for USA and Canada
Moeller® series

www.eaton.com/moellerproducts

Safe Isolation of Main Circuits
with Switch-Disconnectors N or
with Molded Case Switches NS

Motor Starters for USA and Canada
Moeller® series

Anyone wishing to avoid unfortunate experiences, should
make use beforehand of the large number of publications
that Eaton is offering on the issue of exports to North
America. They contain the implementation of the codes &
standards and a description of different practices.

www.eaton.com/moellerproducts

Special considerations governing the
application of Manual Motor Controllers
and Motor Starters in North America

Switchgear and Systems
Moeller® series

Packag
ing
Machin
e

www.eaton.com/moellerproducts

SAFETY
GATE 4
OPEN

Components and Systems for Global Markets

Technical Paper
Dipl.-Ing. Wolfgang Esser

Technical Paper
Dipl.-Ing. Wolfgang Esser

Technical Paper
Dipl.-Ing. Wolfgang Esser
Second, supplemented edition 2010

VKF0211-563.indd 1

28.06.11 13:53

These technical articles can be accessed via
http://www.moeller.net/en/company/news/publications/
index.jsp
They can be downloaded or ordered free of charge.

How to find the right contact:
At Eaton, an efficient customer relationship management is standard practice.
This guarantees you our support right from the start of any new project. Use these contact addresses to
find your personal customer contact:

In just a few steps we can direct you to specialist local support specifically for your business sector.
Your customer contact in your region: Your customer contact worldwide:
http://salesbonn.moeller.net

www.eaton.eu/electrical/contact

Service and consulting for UPS
systems and hydraulic solutions.
Further developing relations with our customers is particularly
important to us. Your requirements and suggestions will be
passed on promptly to the relevant specialists. After all, we
take up the challenges you give us as if they were our own.

Are your questions about uninterruptible
power supplies (USPs)?
Technical support
If you have any questions about our products and for
technical advice send an email to our support team:
supportgermany@eaton.com
or contact our telephone hotline at
Tel.: +49 (0)7841 604 - 334
Service
If you have a problem or a fault on one
of our products contact us by email:
servicegermany@eaton.com
or contact us by phone at:
Tel.: +49 (0)7841 604 - 334
We can be contacted here between
Monday – Thursday from 08.00 – 17.00 CET
and Friday from 08.00 – 16.00 CET.

Are your questions about hydraulic solutions?
Please contact the help desk of our Customer Service
in Baden-Baden. This service will put you in touch with
a customer contact in your locality.
Our customer service:
Eaton Hydraulics Group
Dr.-Reckeweg-Straße 1
D-76532 Baden-Baden
Tel.: +49 (0)7221 682 - 0
Fax: +49 (0)7221 682 - 788
Email: customersupportemea@eaton.com

Eaton's After Sales Service
This is the new name of Moeller‘s tried and trusted Field
Service. Only the name has changed. The reliable and
first-class service has stayed the same. Further information and general terms and conditions can be found at
www.moeller.net/en/support/fieldservice/index.jsp.

Hotline

Service specialists
Use our service personnel. Extensive know-how, combined
with many years of experience and state-of-the-art equipment
to help you find a solution for your tasks.

Onsite service

Free hotline for round-the-clock support.
+49 (0)180 522 3822 (24/7)
0.12 euros per minute for calls from within
the German Telecom network

Repair and replacement service for Eaton devices.

Material
Components, assemblies and spare parts for the Eaton product range are available for your applications.

Repairs

Service products
Eaton‘s After Sales Service offers the right service packages
for your products.

Online services

Onsite service, analysis, conversions, expansions and maintenance.

Downloads, FAQs and interactive troubleshooting

194

1/10
1/8
1/6
1/4
1/3
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
500
b)To

220 - 240 Va,b

110 - 120 V

HP

a)To

Full-load motor-running currents in amperes
corresponding to various AC horsepower ratings
360 - 380 V

440 - 480 V

550 - 600 V

Single
phase

Two
phase

Three
phase

Single
phase

Two
phase

Three
phase

Single
phase

Three
phase

Single
phase

Two
phase

Three
phase

Single
phase

Two
phase

Three
phase

3.0
3.8
4.4
5.8
7.2
9.8
13.8
16.0
20.0
24.0
34.0
56.0
80.0
100
135
-

4.0
4.8
6.4
9.0
11.8
16.6
26.4
38.0
48.0
72.0
94.0
118
138
180
226
-

4.4
6.4
8.4
12.0
13.6
19.2
30.4
44.0
56.0
84.0
108
136
160
208
260
-

1.5
1.9
2.2
2.9
3.6
4.9
6.9
8.0
10.0
12.0
17.0
28.0
40.0
50.0
68.0
88.0
110
136
176
216
-

2.0
2.4
3.2
4.5
5.9
8.3
13.2
19.0
24.0
36.0
47.0
59.0
69.0
90.0
113
133
166
218
-

2.2
3.2
4.2
6.0
6.8
9.6
15.2
22.0
28.0
42.0
54.0
68.0
80.0
104
130
154
192
248
312
360
480
602
-

1.0
1.2
1.4
1.8
2.3
3.2
4.5
5.1
6.4
7.7
10.9
17.9
27.0
33.0
44.0
56.0
70.0
87.0
112
139
-

1.3
1.8
2.3
3.3
4.3
6.1
9.7
14.0
18.0
27.0
34.0
44.0
51.0
66.0
83.0
103
128
165
208
240
320
403
482
560
636
786

2.5
3.5
4.0
5.0
6.0
8.5
14.0
21.0
26.0
34.0
44.0
55.0
68.0
88.0
108
-

1.0
1.2
1.6
2.3
3.0
4.2
6.6
9.0
12.0
18.0
23.0
29.0
35.0
45.0
56.0
67.0
83.0
109
135
156
208
-

1.1
1.6
2.1
3.0
3.4
4.8
7.6
11.0
14.0
21.0
27.0
34.0
40.0
52.0
65.0
77.0
96.0
124
156
180
240
302
361
414
477
590

2.0
2.8
3.2
4.0
4.8
6.8
11.2
16.0
20.0
27.0
35.0
44.0
54.0
70.0
86.0
-

0.8
1.0
1.3
1.8
2.4
3.3
5.3
8.0
10.0
14.0
19.0
24.0
28.0
36.0
45.0
53.0
66.0
87.0
108
125
167
-

0.9
1.3
1.7
2.4
2.7
3.9
6.1
9.0
11.0
17.0
22.0
27.0
32.0
41.0
52.0
62.0
77.0
99.0
125
144
192
242
289
336
382
472

obtain full-load currents for 200 and 208 V motors, increase corresponding 220 - 240 V ratings by 15 and 10 percent, respectively.
obtain full-load currents for 265 and 277 V motors, decrease corresponding 220 - 240 V ratings by 13 and 17 percent, respectively.

Quote from "Power Conversion Equipment - UL 508C, May 3, 2002".
Reproduced from UL 508 C, Power Conversion Equipment, 3rd edition (May 2, 2002) with permission of Underwriters Laboratories Inc.

CA04020001Z-EN-INT

www.eaton.eu

Full-load motor-running currents in amperes
corresponding to various AC horsepower ratings

195

Minimum fuse sizes for short-circuit protection of three-phase motors
The maximum value depends on the switching device or the overload relay.

230 V

400 V

440 V

500 V

690 V

Motor Fuse
rated
opera- Starting
tional
Y/
current DOL

Motor Fuse
rated
opera- Starting
tional
Y/
current DOL

Motor Fuse
rated
opera- Starting
tional
Y/
current DOL

Motor Fuse
rated
opera- Starting
tional
Y/
current DOL

Motor Fuse
rated
opera- Starting
tional
Y/
current DOL

 (%)

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

kWh

p.f.

0.06

0.7

58

0.37

2

–

0.21

2

–

0.19

2

–

0.17

2

–

0.12

2

–

0.09

0.7

60

0.54

2

–

0.31

2

–

0.28

2

–

0.25

2

–

0.18

2

–

0.12

0.7

60

0.72

4

2

0.41

2

–

0.37

2

–

0.33

2

–

0.24

2

–

0.18

0.7

62

1.04

4

2

0.6

2

–

0.54

2

–

0.48

2

–

0.35

2

–

0.25

0.7

62

1.4

4

2

0.8

4

2

0.76

2

–

0.7

2

–

0.5

2

–

0.37

0.72

66

2

6

4

1.1

4

2

1

4

2

0.9

2

2

0.7

2

–

0.55

0.75

69

2.7

10

4

1.5

4

2

1.4

4

2

1.2

4

2

0.9

4

2

0.75

0.79

74

3.2

10

4

1.9

6

4

1.7

4

2

1.5

4

2

1.1

4

2

1.1

0.81

74

4.6

10

6

2.6

6

4

2.4

4

2

2.1

6

4

1.5

4

2

1.5

0.81

74

6.3

16

10

3.6

6

4

3.3

6

4

2.9

6

4

2.1

6

4

2.2

0.81

78

8.7

20

10

5

10

6

4.6

10

6

4

10

4

2.9

10

4

3

0.82

80

11.5

25

16

6.6

16

10

6

16

10

5.3

16

6

3.8

10

4

4

0.82

83

14.8

32

16

8.5

20

10

7.7

16

10

6.8

16

10

4.9

16

6

5.5

0.82

86

19.6

32

25

11.3

25

16

10.2

20

10

9

20

16

6.5

16

10

7.5

0.82

87

26.4

50

32

15.2

32

16

13.8

25

16

12.1

25

16

8.8

20

10

11

0.84

87

38

80

40

21.7

40

25

19.8

32

25

17.4

32

20

12.6

25

16

15

0.84

88

51

100

63

29.3

63

32

26.6

50

32

23.4

50

25

17

32

20

18.5

0.84

88

63

125

80

36

63

40

32.8

63

32

28.9

50

32

20.9

32

25

22

0.84

92

71

125

80

41

80

50

37

80

40

33

63

32

23.8

50

25

30

0.85

92

96

200

100

55

100

63

50

100

63

44

80

50

32

63

32

37

0.86

92

117

200

125

68

125

80

61

125

80

54

100

63

39

80

50

45

0.86

93

141

250

160

81

160

100

74

125

100

65

125

80

47

80

63

55

0.86

93

173

250

200

99

200

125

90

125

100

79

160

80

58

100

63

75

0.86

94

233

315

250

134

200

160

122

160

125

107

200

125

78

160

100

90

0.86

94

279

400

315

161

250

200

146

200

160

129

200

160

93

160

100

110

0.86

94

342

500

400

196

315

200

179

250

200

157

250

160

114

200

125

132

0.87

95

401

630

500

231

400

250

210

250

250

184

250

200

134

250

160

160

0.87

95

486

630

630

279

400

315

254

315

250

224

315

250

162

250

200

200

0.87

95

607

800

630

349

500

400

318

400

315

279

400

315

202

315

250

250

0.87

95

–

–

–

437

630

500

397

630

400

349

500

400

253

400

315

315

0.87

96

–

–

–

544

800

630

495

630

630

436

630

500

316

500

400

400

0.88

96

–

–

–

683

1000

800

621

800

800

547

800

630

396

630

400

450

0.88

96

–

–

–

769

1000

800

699

800

800

615

800

630

446

630

630

500

0.88

97

–

–

–

–

–

–

–

–

–

–

–

–

491

630

630

560

0.88

97

–

–

–

–

–

–

–

–

–

–

–

–

550

800

630

630

0.88

97

–

–

–

–

–

–

–

–

–

–

–

–

618

800

630

Instructions

The rated motor currents apply to normal internally and surfacecooled three-phase motors with 1500 rpm.
DOL starting:
Starting current max. 6 × rated motor current.
Starting time max. 5 s.
Y/-start:
Starting current max. 2 × motor rated current.
Starting time max. 15 s.
Set overload relay in line to 0.58 × motor rated current.

Fuse ratings at Y/ starting apply also to three-phase slipring motors.
For higher rated currents, starting currents and/or longer starting times, larger
fuses will be required. Table applies for time delay and gL fuses (VDE 0636)
For LV h.b.c. fuse with aM characteristics
the fuse should be equal to the rated operational current.

CA04020001Z-EN-INT

www.eaton.eu

Appendix

Motor power

196

Motor lore

Drives egineering selection
criteria
Each drive task requires a drive motor.
The speed, torque and controllability
of each motor must fulfill the
requirements of the task. The following
generally applies:
the application determines the drive.
The drive motor most frequently used
worldwide in industrial plants and
large buildings is the 3-phase
asynchronous motor. Its robust and
simple construction as well as its high
degrees of protection and standard
types are the main features of this
inexpensive electric motor.

Motor connection

V1

W1

W2

U2

V2

Star circuit

L1

U1

L2

V2

L3

W3

L1

U1

L2

V2

L3

△/

14.5 / 8.5 A

1410 min-1
IP 54

L1
ILN

ULN

S1

L3

L1
ILN

W1

W2

U LN =

3  U W , LN = I W

The electrical and mechanical rating
data of the motor must be stated on its
rating plate (IEC 34-1, VDE 0530). The
data on the rating plate describes the
stationary operation of the motor in the
area of its operating point (MN, e.g. at
400 V and 50 Hz). The operational data
is unstable in the motor start phase.
The following examples show the
rating plates for two motors with a
motor shaft output of 4 kW and the
respective connection circuits on a
3-phase AC network with 400 V and
50 Hz.

U1

V1

W1

U1

V1

W1

W2

U2

V2

W2

U2

V2

• With the specified 230/400 V voltage,
this motor must be connected to the
3-phase system (ULN = 400 V) in a
star-connected circuit.
• The voltage of each motor winding is
designed for 230 V. The windings
must therefore be connected in
sequence to the phase voltage (400 V).
• The three winding phases
(W2-U2-V2) are configured in the
terminal box to the so-called star
point. The voltage of the individual
phases to the star point is 230 V
(= UW).

The following figure shows the
characteristic startup curves of a
3-phase asynchronous motor.

L

360°

120°

120°

On the three-phase asynchronous
motor, three windings are arranged
offset from each other by 120°/p
(p = number of pole pairs). To generate
a rotating field in the motor, an
alternating voltage is applied to each
phase in turn at a time delay of 120 °.

MS

f
n:
p
s:

CA04020001Z-EN-INT

www.eaton.eu

ML
nN nS
n

IA: Starting current
IN: Rated operational current at the
operating point
MA: Starting torque
MB: Accelerating torque (MM > ML)
MK: Breakdown torque
ML: Load torque
MM: Motor torque
MN: Rated load torque, (stable operating
point, intersection point of the
3-phase speed torque characteristic
with the load characteristic)
MS: Pull-up torque
n: Speed (actual value)
nN: Rated speed at the operating point
nS: Synchronous speed
(nS - nN = slip speed s)
Synchronous speed:

f
n s = --p
Slip speed in %:

• The three winding phases (U1 – W2,
V1 – U2, W1 – V2) are combined in
the terminal box and connected
directly to the individual phases.

f
n = ---   1 – s 
p

MK

0

• With the specified 400/690 V voltage,
this motor must be connected to the
3-phase system (ULN = 400 V) in a
delta circuit.
• Each motor winding is designed here
for the maximum phase voltage of
400 V and can be connected directly.

3-phase asynchronous motor speed:

IN

270°

120°

3  IW

ns – n
s = --------------  100%
ns

Startup characteristics

Regardless of the circuit type and the
type of three-phase asynchronous
motor, the connections must be
labeled, so that their alphabetical
sequence (e.g. U1, V1, W1)
corresponds with the order of the
mains voltage phase sequence
(L1, L2, L3) and causes the motor to
rotate clockwise.

180°

V2
W1

U LN = U W , LN =

MB

90°

V1

W2

MM

0

L3

U1

MN

L3

L2

U2 V2
U1

M, I I
A
MA

L2

ULN
U2

50 Hz

Iso. KI F

Information on the rating plate

The rotation direction of a motor is
always determined by directly looking
at the drive shaft of the motor (from the
drive end). On motors with two shaft
ends, the driving end is denoted with
D (= Drive), the non-driving end with
N (= No drive).

L1

1410 min-1
IP 54

V1

8.5 / 4.9 A
cos ϕ 0.82

4.0 KW

50 Hz

Iso. KI F

L2

△/

400 / 690 V

cos ϕ 0.82

4.0 KW

W3

REV = reverse run (anticlockwise
rotation field)

Delta circuit

230 / 400 V
S1

Clockwise Anticlockwise operation
(FWD)
(REV)

FWD = forward run (clockwise
rotation field)

When connecting a 3-phase motor to
the mains supply, the data on the
rating plate of the motor must
correspond to the mains voltage and
frequency.
The standard connection is
implemented via six screw terminals in
the terminal box of the motor and with
two types of circuit, the star
connection and the delta circuit,
depending on the mains voltage.
U1

The effect of inductance causes the
rotation field and torque to be formed
in the rotor winding. The speed of the
motor thus depends on the number of
pole pairs and the frequency of the
supply voltage. The operating
direction can be reversed by swapping
over two of the supply phases.

Frequency of voltage in Hz (= s-1)
Speed in r.p.m.
Number of pole pairs
Slip speed in r.p.m.

Electric power:

P 1 = U  I  3  cos 
P1: Electrical power in W
U: Rated operating voltage in V
I: Rated operational current in A
cos ?: Power factor
Motor output (power equation):

MN  n
P 2 = ---------------9550
P2: Mechanical shaft output power in kW
MN: Rated torque in Nm
n: Speed in r.p.m.
Efficiency:

P
 = ----2P1

Eaton Online Catalog – find product
details quickly and efficiently!
You can find comprehensive up-to-date product information at http://ecat.moeller.net

Lookup
You can search by keywords, product names, article numbers,
technical data: The search understands everything and takes
you straight to the product you’re looking for.

Graphical navigation
Graphical representation of the fields of application and
product groups.

Selection aids
Tailored to the typical expert’s approach, this search aid helps
you quickly find the product you need.

HTML data sheet; can be saved as PDF file.

Data sheets
For every article the catalog can generate a technical data
sheet, which you can convert to a PDF file for printing or
saving with a single click.

Parts lists
From your search results you can create a parts list that you
can then send to your Eaton sales partner as a query.

Parts list, e.g. for queries to Eaton Sales.

The power of fusion.

You can find comprehensive up-to-date
information about Eaton’s automation
products and switchgear in our Online
Catalog.

1833

1874

1886

1893

1897

1899

1906

1908

1911

1914

1934

1961

1962

1963

1967

1977

1983

1984

1989

There’s a certain energy at Eaton. It’s the power of uniting some of the
world’s most respected names to build a brand you can trust to meet
your every power management need.
Eaton is dedicated to ensuring that reliable, efficient and safe power
is available when it’s needed most. Building on over 100 years of
experience in electrical power management, the experts at Eaton
deliver customized, integrated solutions to solve your most critical
challenges. To learn more visit www.eaton.eu/electrical.

All of the above are trademarks of Eaton or its affiliates.  Eaton has a license to use the
Westinghouse brand name in Asia Pacific. ©2013 Eaton.

CA04020001Z-EN-INT_Umschlag.indd 7-9

09.07.13 13:20

DC1/DA1 and SVX/SPX variable frequency drives
DS7 and S801+/S811+ soft starters
Rapid Link 4.0 distributed, electronic drive system
Product range catalog for variable frequency drives, soft starters, Rapid Link

Eaton is dedicated to ensuring that reliable, efficient and safe
power is available when it’s needed most. With unparalleled
knowledge of electrical power management across industries,
experts at Eaton deliver customized, integrated solutions to
solve our customers’ most critical challenges.
Our focus is on delivering the right solution for the application.
But, decision makers demand more than just innovative products.
They turn to Eaton for an unwavering commitment to personal
support that makes customer success a top priority. For more
information, visit www.eaton.eu.
To contact an Eaton salesperson or
local distributor/agent, please visit
www.eaton.eu/electrical/customersupport

Product range catalog
Efficient Engineering for
starting and controlling motors.

Changes to the products, to the information contained in this document, and to prices
are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to
Trademarks (especially Eaton, Moeller, Cutler-Hammer). The Terms and Conditions of Eaton
apply, as referenced on Eaton internet pages and Eaton order confirmations.

Eaton Industries GmbH
Hein-Moeller-Str. 7–11
D-53115 Bonn / Germany
© 2012 by Eaton Corporation
All rights reserved
Printed in Germany 07/13
Publication No.: CA04020001Z_EN-INT
Doku/DHW/ip/MP 07/13
Article No.: 170504

CA04020001Z-EN-INT_Umschlag.indd 4-6

Eaton is a registered trademark of Eaton
Corporation
All other trademarks are property of their
respective owners.
SmartWire-DT® is a registered trademark of
Eaton Corporation.

09.07.13 13:19



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Annotate, Fill forms, Extract, Print high-res
Author                          : Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Deutschland/Germany
Create Date                     : 2013:07:23 13:50:37Z
Keywords                        : "PowerXL variable frequency drives, frequency inverter, DC1, DA1, 9000X, SVX, SPX, Soft starters, DS7, S801+, S811+, distributed, electronic drive system Rapid Link, Drives, Power Drives System, PDS, Motor lore, SmartWire DT"
Modify Date                     : 2013:07:24 11:20:05+02:00
Has XFA                         : No
Language                        : en
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Title                           : Product range catalog CA04020001Z-EN
Creator                         : Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Deutschland/Germany
Description                     : Efficient Engineering for starting and control motors
Subject                         : PowerXL variable frequency drives, frequency inverter, DC1, DA1, 9000X, SVX, SPX, Soft starters, DS7, S801+, S811+, distributed, electronic drive system Rapid Link, Drives, Power Drives System, PDS, Motor lore, SmartWire DT
Creator Tool                    : FrameMaker 10.0.2
Metadata Date                   : 2013:07:24 11:20:05+02:00
Producer                        : Acrobat Distiller 10.1.5 (Windows)
Document ID                     : uuid:973d7943-8da8-462f-93d3-6beaf753cb83
Instance ID                     : uuid:3ba59a4c-ec4f-4646-b683-927307e37f15
Page Layout                     : SinglePage
Page Mode                       : UseOutlines
Page Count                      : 177
EXIF Metadata provided by EXIF.tools

Navigation menu