135702 Catalog
2014-10-22
: Pdf 135702-Catalog 135702-Catalog Batch9 unilog
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
J-1 Conduit Outlet Boxes and Bodies: Explosionproof, Dust-Ignitionproof GRSS Effective September, 2005 Copyright 2005 Description 2,3 Features: All Conduit Outlet Boxes and Bodies 4,5 GR Boxes 5 Dimensions 8 Covers 6 GRF Boxes 6 Dimensions 8 Covers 7 GRH Boxes 7 Dimensions 9 ELBY and ELBD Pulling Elbows 9 Elbow Type/Dimensions 10 GRSS Conduit Outlet Boxes 10 Box Type/Dimensions 11 CPU Boxes 11 Covers/Dimensions 12 GRU and GRUE Boxes 12 Dimensions 8 Covers GRU 17 Covers GRUE 13 GRJS Boxes 13 Covers/Dimensions 14 GRJ Boxes 14 Box Type/Dimensions 15 ER Boxes 15 Hub Type/Dimensions 16 GRUO and GRUJ Boxes 16 Covers/Dimensions 17 GRU Union-Hub Boxes 17 Covers/Dimensions 18 GU Boxes 18 Hub Type/Dimensions 19 Wiring Capacity J GU Page 800-621-1506 www.appletonelec.com PAGE 1 J-2 Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Applications Meet a wide range of classified area requirements. Corrosion-resistant–ideal indoors or out. For pulling of wires. Connect conduit lengths and change direction of conduit. Provide access for maintenance. • • • • • Features: All Bodies and Boxes Malleable iron bodies have high tensile strength and ductility. Provides great resistance to corrosion, impact, and shock. Accurately tapped, tapered hub threads for tight, rigid joints and ground continuity. Furnished with covers. General purpose wiring. • • • • Features: GR and GRF ➊GR offers ten hub arrangements. ➋GRF has integral mounting flange. • Function J as sealing fittings when used with sealing covers (see NEC for restrictions). Inter nally threaded body with externally threaded cover. Covers have pry notches for bar or wrench. Accommodate sealing, dome, hub and union hub covers, and canopies. Standard O-rings provide raintight fit. NEMA 3,4. Internal ground screw standard. Smooth, rounded integral bushing in each hub type box protects conductor insulation. • • • • • • Features: GRH ➌Designed for use in Class I, Groups A, B, C, and D; Class II, Groups E, F, and G; and Class III. Inter nally threaded body with externally threaded covers. Standard O-rings provide raintight fit. NEMA 3,4. Internal ground screw standard. Smooth, rounded integral bushing in each hub type box protects conductor insulation. • • • • 14 GU Features: ELBD ➍Exclusive built-in pulling rollers in each end (2-1/2 thru 4” sizes) protect cable from damage and make cable pulling easier. Effective September, 2005 Copyright 2005 PAGE 2 13 GRSS 800-621-1506 www.appletonelec.com Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof J-3 UNILETS® for use with Threaded Metal Conduit. • Excellent for use in wiring of motors, panelboards, circuit breakers, entrances to buildings, etc. Body and cover have ground mating surfaces to meet classified-location requirements. Smooth, rounded integral bushing in each hub type box protects conductor insulation. • • Features: ELBY Serve as pulling fittings. Make 90° bends in conduit. Threaded cover opening permits easy access for pulling conductors thru hubs. Easily removable threaded cover. • • • • Features: CPU Universal design with four threaded universal hubs and three close-up plugs. Serve as mounting outlets for lighting fixtures when used with hub cover. Wide, accurately ground explosionproof mating surfaces. Smooth, rounded integral bushing in each hub type box protects conductor insulation. • • • • • • • • Features: GRJS Universal design with five threaded openings and three close-up plugs. Compact round box for use where space is limited. Serve as mounting means for lighting fixtures when used with hub cover. Function as sealing fittings when • • • Effective September, 2005 Copyright 2005 • • Features: GRJ Small, round conduit outlet boxes. • Function as sealing fittings when used with sealing covers (see NEC for restrictions). Externally threaded body with internally threaded cover. Smooth, rounded integral bushing in each hub type box protects conductor insulation. • • Features: ER Compact, rectangular conduit outlet boxes are ideal in classified locations where space is limited. Six different hub arrangements. Ground surface contact between body and cover assures a flame-tight joint. Smooth, rounded integral bushing in each hub type box protects conductor insulation. • • • Features: GRUO and GRUJ Threaded universal hubs for wiring flexibility. GRUO has eight hubs. GRUJ offers up to eleven hubs. • • Ideally suited for use where space is limited, such as for gasoline pumps. Function as sealing fittings when •used with sealing cover (see NEC for restrictions). Externally threaded body with internally threaded covers. Smooth, rounded integral bushing in each hub type box protects conductor insulation. Features: GRSS and GRSSA Multiple hubs permit flexibility. Copper-free aluminum body and cover provide superior corrosion resistance. Internal ground screw standard. • • 13 • Features: GU Designed for Class I, Groups B,C,D; Class II, Groups E,F,G; and Class III. Exter nally threaded body with internally threaded cover. Smooth, rounded integral bushing in each hub type box protects conductor insulation. Internal ground screw standard. • • • 14 • Standard Materials G R F, G R H , a n d G R J S : Malleable iron bodies with aluminum covers. Aluminum GR Series: Copper-free body and cover. GU, GRUO, GRUJ, GRU (Union), GRJ, CPU, ER, ELBD and ELBY: Malleable iron bodies and covers. GRU, GRUE, and GRSS: Aluminum copper-free bodies and covers. GRG O-Rings: Neoprene. • GR, • • • • Standard Finishes Malleable iron bodies and covers (except ELBY) triple-coat—(1) zinc electroplate, (2) dichromate, and (3) epoxy powder coat. Aluminum bodies and covers: epoxy powder coat. ELBY malleable iron body and cover: zinc electroplate and clear chromate. • • • Compliances UL Standard 886. Federal Spec. W-C-586B. Appleton malleable iron products conform to ASTM A47-77, Grade 32510, which has the following properties: tensile strength, 50,000 psi; yield, 32,000 psi; and elongation, 10%. Appleton aluminum products are produced from a high strength copperfree (4/10 of 1% max.) alloy. Suitable for Class I, Div. 1 & 2, if installed in compliance with NEC 5014(a)(b) and for Class II, Div. 1 & 2, if in compliance with NEC 502-4(a)(b). GR Series: CSA -LR25875-30. • • • • • Features: GRU (Union Hubs) Union hubs permit easy wiring. • • Function as sealing fittings when used with sealing covers (see NEC for restrictions). Externally threaded body with internally threaded cover. Smooth, rounded integral bushing in each hub type box protects conductor insulation. • • • • 800-621-1506 www.appletonelec.com PAGE 3 J Features: GRU and GRUE Universal design with five threaded universal hubs and three close-up plugs. Copper-free aluminum body and cover provide resistance to corrosive atmospheres. Function as sealing fittings when used with sealing covers (see NEC for restrictions). GRU has internally threaded body and externally threaded cover with Oring for raintight fit, NEMA 3,4. GRUE has externally threaded body and internally threaded overlapping cover. Covers have pry notches for bar or wrench. Smooth, rounded integral bushing in each hub type box protects conductor insulation. used with sealing covers (see NEC for restrictions). Inter nally threaded body with externally threaded cover. Smooth, rounded integral bushing in each hub type box protects conductor insulation. J-4 Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 3,4 GR Conduit Outlet Boxes: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Furnished with Internal Ground Screw and O-Ring. Hub Type GRE GRC GRL GRLB J GRN GRT GRX Conduit Size (Inches) Cover Opening (Inches) Cubic Inches Form No.† Catalog Number* Malleable Iron• Aluminum• 1/2 3/4 1 1-1/4 1-1/2 3.38 3.38 3.38 3.94 4.88 18 18 18 31 72 1 1 1 2 3 GRE50 GRE75 GRE100 GRE125 GRE150 GRE50-A GRE75-A GRE100-A GRE125-A GRE150-A 1/2 3/4 1 1-1/4 1-1/2 2 3.38 3.38 3.38 3.94 4.88 4.88 18 18 18 31 72 76 1 1 1 2 3 3 GRC50 GRC75 GRC100 GRC125 GRC150 GRC200 GRC50-A GRC75-A GRC100-A GRC125-A GRC150-A GRC200-A 1/2 3/4 1 1-1/4 1-1/2 2 3.38 3.38 3.38 3.94 4.88 4.88 18 18 18 31 72 76 1 1 1 2 3 3 GRL50 GRL75 GRL100 GRL125 GRL150 GRL200 GRL50-A GRL75-A GRL100-A GRL125-A GRL150-A GRL200-A 1/2 3/4 1 1-1/4 1-1/2 2 3.38 3.38 3.38 3.94 4.88 4.88 18 18 18 31 72 76 1 1 1 2 3 3 GRLB50 GRLB75 GRLB100 GRLB125 GRLB150 GRLB200 GRLB50-A GRLB75-A GRLB100-A GRLB125-A GRLB150-A GRLB200-A 1/2 3/4 1 1-1/4 1-1/2 3.38 3.38 3.38 3.94 4.88 18 18 18 31 72 1 1 1 2 3 GRN50 GRN75 GRN100 GRN125 GRN150 GRN50-A GRN75-A GRN100-A GRN125-A GRN150-A 1/2 3/4 1 1-1/4 1-1/2 2 3.38 3.38 3.38 3.94 4.88 4.88 18 18 18 31 72 76 1 1 1 2 3 3 GRT50 GRT75 GRT100 GRT125 GRT150 GRT200 GRT50-A GRT75-A GRT100-A GRT125-A GRT150-A GRT200-A 1/2 3/4 1 1-1/4 1-1/2 2 3.38 3.38 3.38 3.94 4.88 4.88 18 18 18 31 72 76 1 1 1 2 3 3 GRX50 GRX75 GRX100 GRX125 GRX150 GRX200 GRX50-A GRX75-A GRX100-A GRX125-A GRX150-A GRX200-A * In Class I, Div. 1, Group B atmospheres, all conduit runs must have a sealing fitting (not supplied) field installed adjacent to the enclosure. • Supplied with Aluminum covers. † Form number designates body and matching cover sizes. To order body without cover, add suffix -LC to catalog number. Other covers available—see GR Cover listing page and order separately. See J-8 for optional Terminal Blocks. Effective August, 2008 Copyright 2008 PAGE 4 800-621-1506 www.appletonelec.com Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 3,4 J-5 GR Conduit Outlet Boxes: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Furnished with Internal Ground Screw and O-Ring. Conduit Size (Inches) Cover Opening (Inches) Form No.† Catalog Number* Malleable Iron Aluminum GRCA 1/2 3/4 3.38 3.38 1 1 GRCA50 GRCA75 GRCA50-A GRCA75-A GRLA 1/2 3/4 3.38 3.38 1 1 GRLA50 GRLA75 GRLA50-A GRLA75-A GRTA 1/2 3/4 3.38 3.38 1 1 GRTA50 GRTA75 GRTA50-A GRTA75-A Hub Type * In Class I, Div. 1, Group B atmospheres, all conduit runs must have a sealing fitting (not supplied) field installed adjacent to the enclosure. • Supplied with Aluminum covers. † Form number designates body and matching cover sizes. To order body without cover, add suffix -LC to catalog number. Other covers available—see GR Cover listing page and order separately. See J-8 for optional Terminal Blocks. GR Series, Form 1 Dimensions in Inches Hub Size (In.) B C D E F G 3.75 3.75 3.75 2.44 2.44 2.44 2.88 2.88 2.88 .75 .75 .94 .81 .81 .94 2.25 2.25 2.25 1.25 1.25 1.06 6.2 6.2 6.2 7.3 7.3 7.3 1.9 1.9 2.4 2.1 2.1 2.4 5.7 5.7 5.7 3.2 3.2 2.7 A B C D E F G 4.50 5.75 5.75 2.69 3.75 4.00 3.56 4.81 5.06 1.19 1.38 1.63 .88 .94 1.00 2.75 4.06 4.25 1.13 1.50 1.25 6.8 9.5 10.2 9.1 12.2 12.9 3.0 3.5 4.1 2.2 2.4 2.5 7.0 10.3 10.8 2.9 3.8 3.2 Dimensions in Centimeters 1/2 3/4 1 9.5 9.5 9.5 GR Series, Forms 2 and 3 Dimensions in Inches Hub Size (In.) 1-1/4 1-1/2 2 Dimensions in Centimeters 1-1/4 1-1/2 2 11.4 14.6 14.6 For cubic inches information, see page J-19 Effective August, 2008 Copyright 2008 800-621-1506 www.appletonelec.com PAGE 5 J 1/2 3/4 1 A J-6 Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 3,4 GRF Flanged Conduit Outlet Boxes: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Furnished with Internal Ground Screw and O-Ring. Conduit Size (Inches) Cover Opening (Inches) Form No.† Catalog Number* Malleable Iron Aluminum GRFC 1/2 3/4 1 3.38 3.38 3.38 1 1 1 GRFC50 GRFC75 GRFC100 GRFC50-A GRFC75-A GRFC100-A GRFL 1/2 3/4 1 3.38 3.38 3.38 1 1 1 GRFL50 GRFL75 GRFL100 GRFL50-A GRFL75-A GRFL100-A GRFT 1/2 3/4 1 3.38 3.38 3.38 1 1 1 GRFT50 GRFT75 GRFT100 GRFT50-A GRFT75-A GRFT100-A GRFX 1/2 3/4 1 3.38 3.38 3.38 1 1 1 GRFX50 GRFX75 GRFX100 GRFX50-A GRFX75-A GRFX100-A Hub Type * In Class I, Div. 1, Group B atmospheres, all conduit runs must have a sealing fitting (not supplied) field installed adjacent to the enclosure. † Form number designates body and matching cover sizes. To order body without cover, add suffix -LC to catalog number. Other covers available—see GR Cover listing page and order separately. For cubic inches information, see page J-19 J Effective August, 2008 Copyright 2008 PAGE 6 800-621-1506 www.appletonelec.com Class I, Div. 1 and 2 Groups A,B,C,D Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 3,4 J-7 GRH Conduit Outlet Boxes: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Furnished with Internal Ground Screw and O-Ring. Hub Type Conduit Size (Inches) Cover Opening (Inches) Catalog Number Malleable Iron GRHC 1/2 3/4 1 3.38 3.38 3.38 GRHC50 GRHC75 GRHC100 GRHL 1/2 3/4 1 3.38 3.38 3.38 GRHL50 GRHL75 GRHL100 GRHLB 1/2 3/4 1 3.38 3.38 3.38 GRHLB50 GRHLB75 GRHLB100 GRHT 1/2 3/4 1 3.38 3.38 3.38 GRHT50 GRHT75 GRHT100 GRHX 1/2 3/4 1 3.38 3.38 3.38 GRHX50 GRHX75 GRHX100 J GRH Series Dimensions in Inches Hub Size (In.) 1/2 3/4 1 A B C D E F G 3.75 3.75 3.75 2.44 2.44 2.44 2.63 2.63 2.63 .75 .75 .94 .81 .81 .94 1.63 1.63 1.63 1.25 1.25 1.06 6.2 6.2 6.2 6.7 6.7 6.7 1.9 1.9 2.4 2.1 2.1 2.4 4.1 4.1 4.1 3.2 3.2 2.7 Dimensions in Centimeters 1/2 3/4 1 9.5 9.5 9.5 For cubic inches information, see page J-19 Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 7 J-8 Covers for GR and GRF Conduit Outlet Boxes Covers and O-rings Fit Bodies with Corresponding Form Numbers. Hub Type Cover Opening (Inches) Fixture Stem Size (Inches) Form No.† Catalog Number Malleable Iron Aluminum J Surface 3.38 3.94 4.88 1 2 3 GRK-1M GRK-2M GRK-3M GRK-1 GRK-2 GRK-3 Sealing 3.38 3.94 4.88 1 2 3 GRK-1SC GRK-2SC GRK-3SC GRK-1SC-A GRK-2SC-A GRK-3SC-A Dome 2” deep 3.38 1 Union Hub 3.38 3/4 1 GRK-75U GRK-75UA Hub 3.38 3.38 1/2 3/4 1 1 GRK-50 GRK-75 GRK50-A GRK75-A Canopy Length 4-1/2” 3.38 3.38 3.38 1/2 3/4 1 1 1 1 GRK-50C GRK-75C GRK-100C O-Rings—Buna-N Provide Raintight fit when used on following series: GR (Forms 1, 2 and 3), GRF (Form 1), GRH, and GRU (Form 1). 1 2 3 GRK-1DC Catalog Number GRG-1 GRG-2 GRG-3 GRTB Terminal Strip For use in standard GR series boxes Weidmuller type MK terminal Block* with wire range of #22-#12 AWG. Mounts on 2 predrilled and tapped standard holes (furnished in internal GR boxes). 6 position terminal block kit 6 position terminal block kit 12 position terminal block kit 1+2 3 3 GRTB6-12 GRTB6-3 GRTB12-3 *Terminal block is UL listed for 300 volts, 25 ampere. CSA certified for 300 volts, 13 ampere. †Form numbers designate cover and matching body sizes. Effective September, 2005 Copyright 2005 PAGE 8 800-621-1506 www.appletonelec.com ELBY Series: Class I, Div. 1 and 2 Groups B◆,C,D Class II, Div. 1 and 2 Groups E,F,G Class III ELBD Series: Class I, Div. 1 and 2 Group D Class II, Div. 1 and 2 Groups E,F,G Class III J-9 ELBY and ELBD 90° Pulling Elbows: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Catalog Number Malleable Iron Aluminum Type and Size (Inches) ELBY Capped Elbow 1/2 3/4 1 1-1/4 ELBY-50 ELBY-75 ELBY-100 ELBY-125 ELBY-50-A ELBY-75-A ELBY-100-A ELBY-125-A ELBD-50 ELBD-75 ELBD-100 ELBD-125 ELBD-150 ELBD-200 ELBD-50-A ELBD-75-A ELBD-100-A ELBD-125-A ELBD-150-A ELBD-200-A ELBD-250 ELBD-300 ELBD-350 ELBD-400 ELBD-250-A ELBD-300-A ELBD-350-A ELBD-400-A ELBD Pulling Elbow 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Patented Roller Feature— Listings in Italic Type ELBY Series Dimensions in Inches 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 J Hub Size (Inches) ELBD Series Dimensions in Inches A B C D A B C D E F 2.75 2.88 3.19 4.00 1.44 1.44 1.88 2.31 2.06 2.06 2.56 3.13 1.44 1.44 1.75 2.13 5.06 5.06 7.88 7.88 10.63 10.63 14.69 14.69 28.25 28.25 2.63 2.63 3.44 3.44 4.81 4.81 6.63 6.63 7.50 7.50 4.50 4.50 5.00 5.00 6.75 6.75 9.25 9.25 12.75 12.75 1.06 1.06 1.75 1.75 2.56 2.56 3.75 3.75 4.63 4.63 4.69 4.69 7.50 7.50 10.69 10.69 13.81 13.81 27.56 27.56 2.69 2.69 3.94 3.94 4.94 4.94 6.69 6.69 7.38 7.38 11.9 11.9 19.1 19.1 27.2 27.2 35.1 35.1 70.0 70.0 6.8 6.8 10.0 10.0 12.5 12.5 17.0 17.0 18.7 18.7 Dimensions in Centimeters 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 7.0 7.3 8.1 10.2 3.7 3.7 4.8 5.9 5.2 5.2 6.5 7.9 Dimensions in Centimeters 3.7 3.7 4.5 5.4 12.9 12.9 20.0 20.0 27.0 27.0 37.3 37.3 71.4 71.4 6.7 6.7 8.7 8.7 12.2 12.2 16.8 16.8 19.1 19.1 11.4 11.4 12.7 12.7 17.2 17.2 23.5 23.5 32.4 32.4 2.7 2.7 4.5 4.5 6.5 6.5 9.5 9.5 11.8 11.8 For cubic inches information, see page J-19 ◆Shaded area indicates items suitable for Class I, Group B, in addition to Class I, Groups C, D; Class II, Groups E, F, G; and Class III. Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 9 J-10 Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G Class III GRSS Conduit Outlet Boxes with Multiple Hubs: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Furnished with internal ground screw and O ring gasket. Box Type Conduit Size (In.) Cover Opening (Inches) Hubs Plugs Cubic Inches Catalog Number* Aluminum GRSS Outlet Box with Cover Internally threaded aluminum bodies with externally threaded aluminum form 1 covers. Has 7 hubs; 2 on each of the sides, 1 on the top, 1 on the bottom and 1 on the center in the back. Furnished with 4 close-up plugs and O-Ring. GRSS 1/2 3/4 1 3.38 3.38 3.38 7 7 7 4 4 4 29.0 29.0 29.0 GRSS50 GRSS75 GRSS100 GRSSA Outlet Box with Cover Internally threaded aluminum bodies with externally threaded aluminum form 1 covers. Has 13 hubs; 2 on each side, 2 each on top and bottom and 5 in the back. Furnished with 5 close-up plugs and O-Ring. GRSSA 1/2 3/4 3.38 3.38 13 13 5 5 29.0 29.0 GRSSA50 GRSSA75 Dimensions J For larger size boxes, refer to Catalog Section K. For cubic inches information, see page J-19 * In Group “B” atmospheres, all conduit runs must have a sealing fitting (not supplied) field installed adjacent to the enclosure. Effective September, 2005 Copyright 2005 PAGE 10 800-621-1506 www.appletonelec.com Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G Class III J-11 CPU Universal Conduit Outlet Boxes and Covers: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Box Type Conduit Size (Inches) Fixture Stem Size (Inches) Cover Opening (Inches) Catalog Number Malleable Iron 3.81 CPU20 3.81 3.81 CPU20-50 CPU20-75 CPU Box with Blank Cover (Form 20) Furnished with four threaded universal 3/4” hubs, four 3/4” to 1/2” reducers, and three 1/2” close-up plugs. 1/2 or 3/4 CPU Box with Hub Cover (Form 20) Furnished with four threaded universal 3/4” hubs, four 3/4” to 1/2” reducers, and three 1/2” close-up plugs. 1/2 or 3/4 1/2 or 3/4 1/2 3/4 CPU Covers only (Form 20) Furnished with fastening screws. Blank 3.81 CPSK20B Hub Covers 1/2 3/4 3.81 3.81 CPSK20-50 CPSK20-75 J 1.312” / 3.33 cm Cover CPU Connection Block Phenolic. With fastening strap and two mounting screws. ➤ ➤ 2.875” / 7.06 cm 5-Wire, 20-Ampere, 300 Volt CB205 0.219” / 0.56 cm CPU Dimensions Effective September, 2005 Copyright 2005 For cubic inches information, see page J-19 800-621-1506 www.appletonelec.com PAGE 11 J-12 Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G Class III GRU and GRUE Universal Conduit Outlet Boxes: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Furnished with Internal Ground Screw. GRU furnished with O-Ring. Conduit Size (Inches) Cover Body Opening Form No.† Catalog Number Aluminum 1 1 1 GRU50-A* GRU75-A* GRU100-A GRU Aluminum Box Furnished with externally threaded aluminum surface cover, O-Ring. five threaded hubs, and three close-up plugs. For additional covers, see Page 8. 1/2 3/4 1 3.38 3.38 3.38 GRUE Aluminum Box Furnished with internally threaded aluminum surface cover, five threaded hubs, and three close-up plugs. GRUE50-A* GRUE75-A* GRUE100-A J 1/2 3/4 1 3.38 3.38 3.38 GRU Series Dimensions in Inches Hub Size (Inches) A B 1/2 3/4 1 3.75 3.75 3.75 2.25 2.25 2.44 2.69 2.69 2.88 9.5 9.5 9.5 5.7 5.7 6.2 6.8 6.8 7.3 1.8 1.8 2.4 3.5 3.5 3.7 10.3 10.3 13.8 5.1 5.1 5.6 Dimensions in Inches Hub Size (Inches) A B C D E F G 1/2 3/4 1 4.25 4.25 4.25 2.25 2.25 2.44 2.75 2.75 3.00 4.06 4.06 5.44 2.06 2.06 2.25 5.7 5.7 6.2 7.0 7.0 7.6 C D .69 .69 .94 E 1.38 1.38 1.44 F G 4.06 4.06 5.44 2.00 2.00 2.19 Dimensions in Centimeters 1/2 3/4 1 GRUE Series .69 .69 .94 1.44 1.44 1.50 Dimensions in Centimeters 1/2 3/4 1 10.8 10.8 10.8 1.8 1.8 2.4 3.7 3.7 3.8 10.3 10.3 13.8 5.2 5.2 5.7 For cubic inches information, see page J-19 †For numbers designate body and matching cover sizes. * CSA Certified Effective September, 2005 Copyright 2005 PAGE 12 800-621-1506 www.appletonelec.com Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G Class III J-13 GRJS Universal Conduit Outlet Box: Explosionproof, Dust-Ignitionproof UNILETS® for Use with Threaded Metal Conduit. Box Type Conduit Size (Inches) Cover Opening (Inches) Catalog Number GRJS Universal Box with Cover Internally threaded malleable iron body with externally threaded aluminum surface cover. Complete with five threaded universal openings and three close-up plugs. 1/2 2.56 3/4 2.56 1 2.56 GRJS50 GRJS75 GRJS100 GRJS Covers, Aluminum GRJSK GRJSK-50 Surface Hub GRJS Dimensions in Inches and Centimeters 1/2 2.56 GRJSK 2.56 GRJSK-50 Fraction/Decimal Equivalents (Inches) Decimal 0.06 0.13 0.19 0.25 0.31 0.38 0.44 0.50 0.56 0.63 0.69 0.75 0.81 0.88 0.94 1.00 J Fraction 1/16 1/8 3/16 1/4 5/16 3/8 7/16 1/2 9/16 5/8 11/16 3/4 13/16 7/8 15/16 1 For cubic inches information, see page J-19 Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 13 J-14 Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G Class III GRJ Conduit Outlet Boxes: Malleable Iron; Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Furnished with Internal Ground Screw. Conduit Size (Inches) Cover Opening (Inches) Catalog Number Malleable Iron GRJC 1/2 3/4 2.13 2.13 GRJC50 GRJC75 GRJCA 1/2 3/4 2.13 2.13 GRJCA50 GRJCA75 GRJEA 1/2 3/4 2.13 2.13 GRJEA50 GRJEA75 GRJL 1/2 3/4 2.13 2.13 GRJL50 GRJL75 GRJT 1/2 3/4 2.13 2.13 GRJT50 GRJT75 GRJTA 1/2 3/4 2.13 2.13 GRJTA50 GRJTA75 GRJX 1/2 3/4 2.13 2.13 GRJX50 GRJX75 2.13 GRJK-S J Box Type GRJ Covers Surface For cubic inches information, see page J-19 GRJ Dimensions in Inches and Centimeters Effective September, 2005 Copyright 2005 PAGE 14 800-621-1506 www.appletonelec.com Class I, Div. 1 and 2 Groups D Class II, Div. 1 and 2 Groups E,F,G Class III J-15 ER Conduit Outlet Boxes: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Conduit Size (Inches) Catalog Number Malleable Iron ERC 1/2 3/4 ERC50 ERC75 ERLB 1/2 3/4 ERLB50 ERLB75 ERLL 1/2 3/4 ERLL50 ERLL75 ERLR 1/2 3/4 ERLR50 ERLR75 ERT 1/2 3/4 ERT50 ERT75 ERTB 1/2 3/4 ERTB50 ERTB75 J Box Type ER Dimensions Dimensions in Inches Hub Size (In.) A B C D E F G H 1/2 3/4 3.69 4.00 1.50 1.75 2.00 2.13 5.00 5.44 .56 .69 .69 .69 1.50 1.75 1.06 1.13 3.8 4.5 5.1 5.4 12.7 13.8 1.4 1.8 1.8 1.8 3.8 4.5 2.7 2.9 Dimensions in Centimeters 1/2 3/4 9.4 10.2 For cubic inches information, see page J-19 *If bigger sizes needed, see GR Series on page J-4 Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 15 J-16 Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G Class III GRUO and GRUJ Conduit Outlet Boxes with Multiple Hubs: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Catalog Number Malleable Iron Number and Size of Hubs GRUO Box with Cover Externally threaded malleable iron body complete with internally threaded malleable iron surface cover; eight conduit hubs and close-up plugs for all but three 3/4” hubs. Each Side 1—3/4” Top 2—3/4” Cover opening—3.25” Bottom 2—3/4” 1—1” Back 1—3/4” GRUO-2 GRUJ Box with Cover Externally threaded malleable iron body complete with internally threaded malleable iron surface cover; choice of hub arrangements, furnished with close-up plugs for all but three 3/4” hubs. Each Side 2—3/4” 2—3/4” 2—3/4” Top 2—3/4” 2—3/4” 2—3/4” Bottom 1—3/4” 1—3/4” 1—3/4” Back None 4—3/4” 4—1” GRUJ-1P GRUJ-2P GRUJ-3P Cover opening—3.25” GRU Covers J Malleable iron with internal threads. For GRUO and GRUJ listed above. Surface GRUK-S Cover opening—3.25” For cubic inches information, see page J-19 Effective September, 2005 Copyright 2005 PAGE 16 800-621-1506 www.appletonelec.com J-17 Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 3,4* GRU Conduit Outlet Boxes with Union Hubs: Explosionproof, Dust-Ignitionproof UNILETS® for use with Threaded Metal Conduit. Furnished with Internal Ground Screw. Box Type GRUT50 Conduit Size (Inches) Cubic Inch Capacity Catalog Number Cover Opening (Inches) Malleable Iron Aluminum GRU with Union Hubs GRUT 1/2” thru 1” and GRUSE 1/2” thru 3/4” — Malleable iron externally threaded body complete with internally threaded malleable iron surface cover. GRUSE 1” — Copper free aluminum cover and body with externally threaded cover GRUT GRUSE GRUT50 1/2 19 3.25 3/4 19 3.25 GRUT75 1 19 3.25 GRUT100 1/2 19 3.25 GRUSE50 3/4 19 3.25 GRUSE75 1 29 3.75 GRUSE100 GRUSE50 GRU Covers Malleable iron with internal threads.Fit GRUT and GRUSE listed aboveg. Surface * Applies to GRUSE100 only. GRUK-S 3.25 g Does not apply to GRUSE100 Dimensions GRUT GRUSE50 and GRUSE75 GRUT Dimensions in Inches J Hub Size (Inches) A 1/2 3/4 1 4.19 4.19 4.19 B 2.69 2.69 2.69 C D 6.25 6.25 6.50 .75 .75 .94 E F 8.25 8.25 8.75 2.31 2.31 2.31 Dimensions in Centimeters GRUSE100 1/2 3/4 1 10.6 10.6 10.6 6.8 6.8 6.8 15.9 15.9 16.5 1.9 1.9 2.4 21.0 21.0 22.2 5.9 5.9 5.9 GRUSE 1/2” and 3/4” Dimensions in Inches Hub Size (Inches) A B C 1/2 and 3/4 4.19 2.56 6.13 D E .94 8.00 F G 2.19 2.13 Dimensions in Centimeters 1/2 and 3/4 10.6 6.5 Effective August, 2008 Copyright 2008 15.6 2.4 20.3 5.7 5.4 800-621-1506 www.appletonelec.com PAGE 17 J-18 Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G Class III GU Conduit Outlet Boxes: Explosionproof, Dust-Ignitionproof UNILETS® for Use with Threaded Metal Conduit. Furnished with Internal Ground Screw. Hub Type Conduit Size (Inches) Cover Opening (Inches) Catalog Number* Malleable Iron J GUC 1/2 3/4 1 3.38 3.38 3.38 GUC50 GUC75 GUC100 GUL 1/2 3/4 1 3.38 3.38 3.38 GUL50 GUL75 GUL100 GULB 1/2 3/4 1 3.38 3.38 3.38 GULB50 GULB75 GULB100 GUT 1/2 3/4 1 3.38 3.38 3.38 GUT50 GUT75 GUT100 GUX 1/2 3/4 1 3.38 3.38 3.38 GUX50 GUX75 GUX100 Dimensions in Inches and Centimeters GU Series Dimensions in Inches Hub Size (Inches) A B C D E F 1/2 3/4 1 4.28 4.28 4.28 2.44 2.44 2.44 2.97 2.97 2.97 .75 .75 .94 .81 .81 .94 2.25 2.25 2.25 10.9 10.9 10.9 6.2 6.2 6.2 7.5 7.5 7.5 1.9 1.9 2.4 2.1 2.1 2.4 5.7 5.7 5.7 Dimensions in Centimeters 1/2 3/4 1 For cubic inches information, see page J-19 * In Group “B” atmospheres, all conduit runs must have a sealing fitting (not supplied) field installed adjacent to the enclosure. Effective June, 2008 Copyright 2008 PAGE 18 800-621-1506 www.appletonelec.com J-19 Wiring Capacity: Explosionproof Conduit Outlet Boxes Volume in Cubic Inches and Cubic Centimeters Wiring Capacity Size CPU ER ER GR GR GR Form 20 1/2” 3/4” Form 1 Form 2 Form 3 (1-1/2”) Form 3 (2”) All All All All -50C, -75C, -100C 1DC 1/2”, 3/4” 1/2”, 3/4” 1” 1/2”, 3/4” 1” All All All All All GRF GRH GRJ GRJS GRK (Canopy)GRK (Dome) GRU (Union Hubs) GRU (Universal) GRUE GRUJ GRUO GRSS GRSSA GU Vol./cu. in. Vol./cu. cm 21.0 4.8 7.3 18.0 31.0 72.0 76.0 18.0 13.8 7.3 12.5 16.0 6.0 19.0 13.5 17.5 15.3 18.5 25.0 25.0 29.0 29.0 19.0 344.1 78.7 119.3 295.0 508.0 1179.9 1245.4 295.0 226.2 119.3 204.8 262.2 98.3 311.4 221.2 286.8 250.7 303.2 409.7 409.7 475.2 475.2 311.4 JJ Type ELBD 90° Pulling Unilets Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Capacity in Cubic Inches ELBD 7.0 7.0 25.0 25.0 69.0 69.0 240.0 240.0 540.0 540.0 3932.9 8849.0 8849.0 Capacity in Cubic Centimeters ELBD 114.7 GRSS Effective September, 2005 Copyright 2005 114.7 409.7 GU 409.7 1130.7 1130.7 3932.9 ELBD 800-621-1506 www.appletonelec.com PAGE 19 J-20 ® J Effective September, 2005 Copyright 2005 PAGE 20 800-621-1506 www.appletonelec.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2008:11:07 09:43:57-06:00 Create Date : 2008:10:14 13:58:52-05:00 Metadata Date : 2008:11:07 09:43:57-06:00 Format : application/pdf Title : untitled Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:06bb9d0f-4178-4a55-9aa7-6cc7ba958263 Instance ID : uuid:8a185ba6-d7b0-4da9-966d-60ba6cc23c3f Page Count : 20 Page Layout : OneColumnEXIF Metadata provided by EXIF.tools