SECTION

GFCI Personnel Safety Devices
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

SmartLock PRO ™ GFCI Devices
SmartLockPRO GFCI devices comply with 2006 UL requirements
™

HOSPITAL GRADE

COMMERCIAL GRADE

• Power/Diagnostic
Indicator
• 15 & 20Amp
Configurations
• Back and Side Wired
• Color Match
Test/Reset Buttons

• Power/Diagnostic
Indicator
• 15 & 20 Amp
Configurations
• Back and Side Wired
• Color Match
Test/Reset Buttons

(Monochromatic)

SmartLockPRO™ GFCI Device Types

• Green LED Indicates
Power and Confirms
Proper Wiring Status
• Resistant to Surge,
Noise, and Corrosion
7899-HGR
Per 2006 UL
Requirements
PAGE F3, Section H

PAGE F3

COMBO

HIGH CURRENT

• 15 Amp Single GFCI
Receptacle with
Single-Pole Switch
• Switch Rated 15A at
120V AC
• Back and Side Wired
• Color Match
Test/Reset Buttons
(Monochromatic)

• Resistant to Surge,
Noise, and Corrosion
Per 2006 UL
Requirements
7299-A

8895-80E

PAGE F3

WORK LIGHT

ANGLE PLUGS
Recognized
Component

GFCI Cord Sets
• 15A & 20A 125V; 15A & 20A 240V
• Automatic and Manual Reset Types
• Orange Power Status Indicator
• Yellow Cord 14/3 SJT
• Resistant to Surge, Noise, & Corrosion
Per 2006 UL Requirements
PAGES F6 & F7

Right Angle GFCI Plugs
• 15A 125V; 20A 125V
• Automatic and Manual
Reset Types
• Power Status Indicator
• Available in Dark Gray
and Yellow
• Consult factory for
availability

66591-WL

36596

Panel Mount GFCI with 16" Leads
• 20A 125V
• Orange LED Indicator Light
• Weather-Resistant Housing &
Test/Reset Buttons
• Resistant to Surge, Noise, and
Corrosion Per 2006 UL Requirements
PAGE F4

Recognized
Component
Blank Face
• Contact Rating:
20A 125V
• Control Relay: 80 Amps
240V AC Max.
• Side Wired
• Color Match Test/Reset
Buttons (Monochromatic)
• Resistant to Surge,
Noise, and Corrosion
Per 2006 UL Requirements

PAGE F4

Recognized
Component

66591-25C

1

7599-LW

• Resistant to Surge,
Noise, and Corrosion
Per 2006 UL
Requirements
• 6" leads ideal for OEM
applications

PAGE F3

(Monochromatic)

CORD SETS

F

•

(Monochromatic)

7599-T

• Resistant to Surge,
Noise, and Corrosion
Per 2006 UL
Requirements

PANEL MOUNTS

• Power/Diagnostic
Indicator
• 15 & 20 Amp
Configurations
• Back and Side Wired
• Color Match
Test/Reset Buttons

(Monochromatic)

• 20 Amp with Switch
Rated Test/ Reset
Buttons
• Back and Side Wired
• Color Match
Test/Reset Buttons

PAGE F3

w/Wire Leads

• Resistant to Surge,
Noise, and Corrosion
Per 2006 UL
Requirements

BLANK FACE

7590-W

COMMERCIAL GRADE

Fluorescent Work Light with GFCI
Protected Receptacle
• 13 Watt Lamp and Receptacle
• Black Body with 20' Yellow Cord 16/3 SJTW
• NEMA 5-15R Receptacle; NEMA 5-15P Plug
• Automatic Reset In-Line GFCI with Power
Status Indicator

16593

PAGE F4

PAGE F4

NEW UL943 GFCI
SAFETY STANDARDS

POWER CENTER

PB101-SGF

“THE BOX”™
• 6 GFCI Protected 20A 125V Straight
Blade or Locking Receptacles
• GFCI Protected 30A 250V Locking Receptacle
• 50A 125/250V Non-NEMA Power Connections
• Meets OSHA Regulation 20, Subpart K
Standards
• UL Listed for Outdoor Use
PAGE F8

To learn more about Leviton devices or for answers to technical questions call our Techline at

Effective July 28, 2006
See Page F10
for Full Details

1-800-824-3005 or visit us at:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

e

www.barr-thorp.com

www.leviton.com

SmartLockPRO ™ GFCI Features
UL Standard 943 Class A (GFCI) & 498 (Receptacles)
CSA Certified (File #057)
Meets July 28, 2006 UL Requirements
Thick-walled, impact-resistant
thermoplastic nylon cover and
body withstands abuse

Heavy duty double wipe for
15 Amp contacts and triple
wipe for 20 Amp contacts

“Surge hardened” electronics
offer superior resistance to
surges and overvoltages.

Silver alloy contacts for reliable
make/break switching.

Patented lockout feature prevents
“RESET” if GFCI is not functioning
properly or miswired due to reversal of
line and load leads.

LED power indicator light helps
diagnose improper wiring and,
when illuminated, offers visual
confirmation that power is
available.
Eight back-wire holes
(two per terminal) and
back-wire ground.

7599-W

Provisions for backor side-wiring.

Leviton SmartLockPRO™ icon
ensures improved GFCI
product design.

Lockout action blocks the “RESET”
button if GFCI protection has been
compromised.

COMPONENT

Nylon

Back

Polycarbonate

Line Contacts

Brass

Terminal Screws

Brass #8-32

Grounding Screw

Brass #8-32

Yoke

Zinc Steel

Clamp Nuts
Internal Contacts

Steel
Silver Alloy

NEMA

ANSI

WD1&WD6

C-73

STANDARDS & CERTIFICATIONS
UL
UL 943
CSA
Listed
Class A & 498

U

U

#E48380

U

#LR-57811

Dual function LED offers indication
of line/load reversal &
power availability.

Leviton SmartLockPRO™ and The New 2006
UL943 GFCI Safety Standards

DESCRIPTION

Face

SmartLockPRO™ GFCI Features

Triple combination
terminal screws.

Line-Load Reversal Indication
New UL 2006 Standard:
• If a miswiring (line-load reversal) occurs during installation,
the GFCI must not be capable of supplying power to either
the GFCI’s face or to feed-through terminals.

“End-of-Life” Indication
New UL 2006 Standard:
• GFCIs are required to provide a visual and/or audible
NOM

#057

indication OR be able to render themselves incapable of
delivering power when they no longer offer ground fault
protection based on a failure to pass their internal test.
For additional details on these new requirements, see page F10.

To learn more about Leviton devices or for answers to technical questions call our Techline at

1-800-824-3005 or visit us at:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

e

www.barr-thorp.com

www.leviton.com

F
2

15A 125V & 20A 125V
Hospital & Commercial Grade, GFCI’s
ELECTRICAL
DIELECTRIC
VOLTAGE

CURRENT
INTERR.

Withstands
1500V
per
UL 498

2kA

TERMINAL
TERMINAL
I.D.
ACCOMMODATION
Brass, hot

80ºC max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC appl.
per UL 498

TRIP LEVEL
5±1 mA

STANDARDS & CERTIFICATIONS

MECHANICAL
TEMP.
RISE

#14 - #12 AWG
solid or stranded
copper wire

Grounding
Silver, neutral

NEMA ANSI
WD-6 C-73

PRODUCT
I.D.
Ratings
permanently
marked
on device

UL
UL
943 Fed Spec
Class A
Listed
& 498 WC-596

U U U

ENVIRONMENTAL

–

CSA

NOM

C22.2

#LR-57811 #057

MISC. MOTOR CONTROL RATING

FLAMMABILITY

OPERATING TEMP.

Rated V-2 per UL 94

-35ºC to 65ºC

15A-1875W
20A-2500W

Hospital & Commercial Grade GFCI Devices

Back & Side Wired

FACE
COLOR

7899-HGR

7599-I

7599-LI

7590-W

GFCI
HOSPITAL GRADE
SMARTLOCKPRO ™
DUPLEX w/ LED

GFCI
COMMERCIAL GRADE
SMARTLOCKPRO ™
DUPLEX w/ LED

GFCI
COMMERCIAL GRADE
SMARTLOCKPRO ™
DUPLEX w/ LED

GFCI
COMMERCIAL GRADE
BLANK FACE
S-P SWITCH
1.5HP@120V AC

Meets 2006
UL Requirements

Meets 2006
UL Requirements

Meets 2006
UL Requirements

Meets 2006
UL Requirements

Brown
Ivory
White
Gray
Red
Black
Almond
Lt. Almond

7599-HG
7599-HGI
7599-HGW
7599-HGG
7599-HGR
–
7599-HGA
7599-HGT

Brown
Ivory
White
Gray
Red
Black
Almond
Lt. Almond

7899-HG
7899-HGI
7899-HGW
7899-HGG
7899-HGR
7899-HGE
7899-HGA
7899-HGT
FACE
COLOR

w/ 6" Leads.

15A 125V, NEMA 5-15R; 20A 125V Feed-Through
–
7599
7599-I
7599-LI
7599-W
7599-LW
7599-G
–
7599-R
–
7599-E
–
–
7599-A
7599-T
–
20A 125V, NEMA 5-20R at Receptacle & Feed-Through
7899
–
7899-I
7899-LI
7899-W
7899-LW
7899-G
–
–
–
7899-E
–
7899-A
–
7899-T
–

GFCI COMBO DEVICE RECEPTACLE
& SINGLE-POLE SWITCH

–
7590-I
7590-W
–
–
7590-E
7590-A
7590-T
–
–
–
–
–
–
–
–
SHALLOW WALLBOX
EXTENDER
FOR GFCI's

COLOR

Meets 2006 UL Requirements

15A 125V, NEMA 5-15R;
20A 125V Feed-Through
Ivory
White
Almond

Brown
Ivory
White

7299-I
7299-W
7299-A

6197
6197-I
6179-W

7299-A
0.94
(23.88 mm)

0.94
(23.88 mm)

20 AMP

2.7 (68.6 mm)

4.21 (106.93 mm)

2.7 (68.6 mm)

4.21 (106.93 mm)

125V

3.81 (96.77 mm)

3.28 (83.81 mm)

2.62 (66.55 mm)
0.29 (7.37 mm)

3.81 (96.77 mm)
3.28 (83.81 mm)

CLASS

0.29 (7.37 mm)

GFCI

GFCI

3.70 (93.98 mm)

7899-HG SERIES

4.21 (106.93 mm)

1.31
(33.27 mm)

2.74 (69.60 mm)

3

1.19
(30.23 mm)

4.21 (106.93 mm)
3.70 (93.98 mm)

F

2.74 (69.60 mm)

2.62 (66.55 mm)

LEVITON
CLASS A

1.12 (28 mm)

1.12 (28 mm)
1.19
(30.23 mm)

1.31
(33.27 mm)

7599 SERIES

1.53 (38.9 mm)

1.7 (43.2 mm)

1.7 (43.2 mm)

7590 SERIES

To learn more about Leviton devices or for answers to technical questions call our Techline at

7299 SERIES

1-800-824-3005 or visit us at:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

1.53 (38.9 mm)

e

www.barr-thorp.com

www.leviton.com

15A 125V & 20A 125V
Commercial Grade, GFCI’s
ELECTRICAL
DIELECTRIC
VOLTAGE

CURRENT
INTERR.

Withstands
1500V
per
UL 498

2kA

STANDARDS & CERTIFICATIONS

MECHANICAL
TEMP.
RISE

TERMINAL
TERMINAL
I.D.
ACCOMMODATION
Brass, hot

30ºC max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498

TRIP LEVEL
5±1 mA

#18- #12 AWG

Grounding
Silver, neutral

NEMA ANSI
WD-6 C-73

PRODUCT
I.D.
Ratings
permanently
marked
on device

UL
UL
943 Fed Spec
Class A
Listed
& 498 WC-596

U U U

ENVIRONMENTAL

–

CSA

NOM

C22.2

#LR-57811 #057

MISC. MOTOR CONTROL RATING

FLAMMABILITY

OPERATING TEMP.

Rated V-2 per UL 94

-35ºC to 66ºC

15A-1875W
20A-2500W

Recognized Component*

Right Angle GFCI Plugs
PLUG
COLOR

Refer to footnote
16594 under Right Angle
GFCI Plugs Table

16893

16593

ANGLE PLUG
AUTOMATIC
RESET

Black
Yellow

86593

Right Angle Plugs Accessory

ANGLE PLUG

MANUAL
RESET

AUTOMATIC
RESET

COLOR

15A 125V, NEMA 5-15P

20A 125V, NEMA 5-20P

16593
–

16893
–

–
16594

WATERPROOF COVER
WITH GROUND PIN UP
ORIENTATION

MANUAL
RESET

Clear

–
16894

86593

*Catalog numbers 6593, 6893, 6594 and 6894 series are available – consult factory. For additional information,
see catalog L-100, page H5.

High Current GFCI

Rated 20A-125 VAC

Contact Rating: 20A 125V AC
Load Capability with 125V Control Relay
80@240V AC Max.

PANEL MOUNT FOR TEMPORARY
POWER DISTRIBUTION BOXES

TOGGLE
COLOR

36597
PANEL MOUNT GFCI FOR
PHASE-CONTROL THEATER
DIMMING SYSTEMS

Ivory
Front View

36895

Recognized Component

BLANK FACE
RESET BUTTONS

Side View

8895-80I

White

8895-80W

Black

8895-80E

Recognized Component

GFCI-Protected Fluorescent Work Light w/Receptacle
15A 125V, 2-P 3-W Grounding
LENGTH

GFCI CORD SET, YELLOW CORD, 16/3 SJTW
BLACK BODY, ON/OFF POWER SWITCH,
13 WATT LAMP

20’

NEMA
PLUG

G

66591-WL

W

Commercial Grade GFCI Devices

Wiring Termination Area

NEMA
CONNECTOR

5-15P

G
W

5-15R

2.58 (65.5 mm)

OFF

.810
(20.6 mm)
2.7 (68.6 mm)

20 AMP
FOLLOW DIRECTIONS
SUIVEZ INSTRUCTION

4.21 (106.93 mm)

125V

.023 REF.

5.12 (130 mm)

4.75 (121 mm)

2.7 (68.6 mm)

TEST
TEST

3.8 (96.5 mm)

ON
RESET

CLASS

1.29 DIA.
(33 mm)

SWITCH

TEST MONTHLY
TEST MENSUEL

TEST

1.77 (45 mm)
LEVITON
CLASS A

2.40 (64 mm)

GFCI

RESE

~~~~~~~
~~~~~~
~~~~~~~

1.83 DIA.
(49 mm)
1.60 DIA.
(41 mm)

RESET

1.74 (44.2 mm)

GROUND FAULT CIRCUIT
INTERRUPTER-MISC. MOTOR
CONTROLLER AND SWITCH

15A 125V
RECEPTACLE

1.12 (28 mm)
1.26 (32 mm)

1.7 (43.2 mm)

36596, 36597, 36895

RIGHT ANGLE GFCI PLUGS

To learn more about Leviton devices or for answers to technical questions call our Techline at

8895

1-800-824-3005 or visit us at:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

e

www.barr-thorp.com

www.leviton.com

F
4

GFCI Cord Set Features
Water-resistant SJTW-A cable
(14/3 for 15A, 12/3 for 20A)

GFCI Cord Set Features

Available in 2-ft., 6-ft. and 25-ft.
lengths, except where indicated

Equipped with Industrial Grade plugs and
connectors to provide long service life in
heavy-duty applications

Agency Standards

RTV injected at cord entrance and
exit of the housing

• Complies with UL Standard 943 as a
Recognized Component Class A GFCI
power supply with open neutral protection

Choice of Automatic or Manual
reset models

• UL Listed (File #E-48380), 15A devices also
CSA Certified (File #LR-5781)
• Fully complies with NEC code article #527.6,
6(A) and 6(B) and OSHA regulation CFR
1926-404b(i)(ii) for construction sites

Power indicator light goes OFF if
GFCI trips, power is interrupted
or line cord is unplugged

GFCI Cord Set Features

• In-line GFCI units are NEMA 3R

Water-resistant enclosure sealed
by ultrasonic welding to ensure
long service life

69593-3

Cat. No. 66591-WL
Provides lighting and GFCI protection in
out-of-the-way locations

Custom lengths and configurations
available as special order

Manual Reset GFCI Cord Sets with
Wetguard® plugs and connectors provide
outstanding corrosion-resistance where
water is present

GFCI Protection: An OSHA Requirement on the Job Site
OSHA definitely means business, with fines for willful violations reaching as high as $70,000! The second
most common OSHA electrical violation at construction sites involves non-compliance with either the
Assured Equipment Grounding Program or Ground Fault Protection. Whichever program you choose,
portable GFCI Cord Sets or an approved grounding conductor program, make sure it is used 100% of the
time. Ignoring OSHA requirements can cost money as well as business. Compliance with OSHA and NEC
standards is absolutely mandatory, and use of Leviton GFCI Cord Sets is a reliable, economical way to
accomplish that.

GFCI Cord Sets Must Have Open-Neutral Protection
Open-Neutral Protection immediately trips the GFCI if the neutral conductor on the line side is opened.
This eliminates the possibility of the GFCI Cord Set having a live hot leg, even though it may appear as
though power is off due to the open neutral. A normal GFCI receptacle would not be able to trip under
these conditions.

Automatic vs. Manual Reset Cord Sets
Automatic Reset GFCI Cord Sets (black body) automatically reset ON when power is restored. Manual Reset
units (yellow body) will not automatically reset after power interruption; the reset button must be pushed in.

F
5

Automatic Reset GFCI Cord Sets and Extension Cords – Black Body
• Automatically resets to ON when plugged in or after power interruption
• Available in 2-ft, 6-ft and 25-ft lengths except where indicated
To learn more about Leviton devices or for answers to technical questions call our Techline at

1-800-824-3005 or visit us at:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

e

www.barr-thorp.com

www.leviton.com

15A 125V& 250V;20A 125V & 250V
Automatic Reset GFCI Cord Sets & Power Supply Cords
ELECTRICAL
DIELECTRIC
VOLTAGE

CURRENT
INTERR.

Withstands
1500V
per
UL 498

2kA

TERMINAL
TERMINAL
I.D.
ACCOMMODATION
Brass, hot

5±1 mA

Not Applicable

Grounding
Silver, neutral

PRODUCT
I.D.
Ratings
permanently
marked
on device

ENVIRONMENTAL

NEMA ANSI
WD-6 C-73

UL
UL
943 Fed Spec
Class A Listed
& 498 WC-596

U U U

–

CSA

#LR-57811 #057

MISC. MOTOR CONTROL RATING

FLAMMABILITY

OPERATING TEMP.

Rated V-2 per UL 94

-35ºC to 66ºC

15A-1875W
20A-2500W

Automatic reset GFCI cord sets (black body) automatically reset ON when power is restored.

66891-3

66593-3

66591-25C

FACTORY-ASSEMBLED CORD SETS — Consult Techline for changes in length and/or configurations.
LENGTH

GFCI CORD SET AUTOMATIC RESET
(15 AMP) 14/3 SJTW
(20 AMP) 12/3 SJTW
YELLOW CORD, BLACK BODY
BLACK PLUG & CONNECTOR

NEMA
PLUG

NEMA
CONNECTOR

15A 125V, Cord Sets
2'
6'
25'

66591-2C
66591-6C
66591-25C

5-15P

5-15R

15A 125V, Cord Set Triple Outlet
3'

66593-3
5-15P

5-15R

15A 125V, Locking Cord Set
3'

66597-3
L5-15P

L5-15R

15A 125V, Power Supply Cord
37'

26591-37C

–
5-15P

15A 240V, Power Supply Cord
35'

26592-E

–
6-15P

20A 125V, Cord Sets
3'

66891-3
5-20P

5-20R

20A 125V, Locking Cord Set
3'

NOM

C22.2

Automatic Reset GFCI Cord Sets & Power Supply Cords

30ºC max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498

TRIP LEVEL

STANDARDS & CERTIFICATIONS

MECHANICAL
TEMP.
RISE

66897-3
L5-20P

L5-20R

20A 125V, Power Supply Cord
37'

36591-37C

–
5-20P

20A 240V, Power Supply Cord
35'

36592-E

–
6-20P

To learn more about Leviton devices or for answers to technical questions call our Techline at

1-800-824-3005 or visit us at:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

e

www.barr-thorp.com

www.leviton.com

F
6

15A 125V;20A 125V
1 YEAR LIMITED

Manual Reset GFCI Cord Sets
ELECTRICAL
DIELECTRIC
VOLTAGE

CURRENT
INTERR.

Withstands
1500V
per
UL 498

2kA

TERMINAL
TERMINAL
I.D.
ACCOMMODATION
Brass, hot

TRIP LEVEL
5±1 mA

STANDARDS & CERTIFICATIONS

MECHANICAL
TEMP.
RISE
30ºC max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498

Not Applicable

Grounding
Silver, neutral

PRODUCT
I.D.
Ratings
permanently
marked
on device

NEMA ANSI
WD-6 C-73

UL
UL
943 Fed Spec
Class A
Listed
& 498 WC-596

U U U

ENVIRONMENTAL

–

CSA

#LR-57811 #057

MISC. MOTOR CONTROL RATING

FLAMMABILITY

OPERATING TEMP.

Rated V-2 per UL 94

-35ºC to 66ºC

15A-1875W
20A-2500W

Manual reset units (yellow body) will not automatically reset
after power interruption; the reset button must be pushed in.

69591-W3

69891-3

Manual Reset GFCI Cord Sets

FACTORY-ASSEMBLED CORD SETS - Consult Techline for changes in length and/or configurations.
LENGTH

GFCI CORD SET MANUAL RESET
(15 AMP) 14/3 SJTW
(20 AMP) 12/3 SJTW
YELLOW CORD,YELLOW BODY
YELLOW PLUG & CONNECTOR

NEMA
PLUG

NEMA
CONNECTOR

15A 125V, Cord Sets
3'
25'

69591-3
69591-25

5-15P

5-15R

15A 125V, Cord Set Triple Outlet

3'

69593-3

5-15P

5-15R

15A 125V, W/ Wetguard Plug & Connector Cord Set
3'
25'

69591-W3
69591-W25

5-15P

5-15R

20A 125V, W/ Wetguard Plug & Connector Cord Set

3'

69891-W3

5-20P

5-20R

69591-W3
1.78 (45.2 mm)

69593-3

6.70 (170.2 mm)

36.0 (914.4 mm)

6.70 (170.2 mm)

0.63 (15.6 mm)
2.50 (63.5 mm)

(9.32 ± 2 mm)

15A AUTO GFCI CORD
66591-2C — on page F6
To learn more about Leviton devices or for answers to technical questions call our Techline at

2.50 (63.5 mm)

TEST

RESET

7

RESET

1.63 (41.1 mm)

TEST BEFORE EACH USE

F

TEST

FOLLOW DIRECTIONS

0.367± 0.07

MANUAL RESET GFCI CORD
69591-W3
1-800-824-3005 or visit us at:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

e

www.barr-thorp.com

NOM

C22.2

www.leviton.com

50A 125/250V
1 YEAR LIMITED

Power Center “THE BOX” & Power Cords
ELECTRICAL
CURRENT
INTERR.

Withstands
1500V
per
UL 498

2kA

STANDARDS & CERTIFICATIONS

MECHANICAL
TEMP.
RISE

TERMINAL
TERMINAL
I.D.
ACCOMMODATION
Brass, hot

30ºC max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498

TRIP LEVEL
5±1 mA

Not Applicable

Grounding
White,neutral

NEMA ANSI
WD-6 C-73

PRODUCT
I.D.
Ratings &
NEMA I.D.
permanently
marked on device

U

UL
UL
943 Fed Spec
Class A Listed
& 498 WC-596

U U

ENVIRONMENTAL

–

CSA

NOM

C22.2

#LR-57811 #057

OSHA

FLAMMABILITY

OPERATING TEMP.

Rated V-2 per UL 94

-35ºC to 66ºC

“The Box” Meets Regulation 20, Part 1926,
Subpart K Standards

Power Distribution Box
Available with or without GFCI Protection on 30A Receptacles Consult Factory for Other Configurations
Power Inlet
Non-NEMA
50A, 125/250V

Catalogue No.

Power Outlet
Non-NEMA
50A, 125/250V

6 NEMA Locking
Receptacles
20A, 125V, L5-20R

6 NEMA Straight
Blade Receptacles
20A, 125V, 5-20R

1 NEMA Locking
Receptacle
30A, 250V, L6-30R

PB101-SGF

No GFCI

✔

Protection

No GFCI

✔

Protection

GFCI

✔

Protection

GFCI

✔

PB101-000

No GFCI

✔

Protection

No GFCI

✔

Protection

GFCI

✔

Protection

No GFCI

✔

Protection

PB103-SGF

No GFCI

✔

Protection

No GFCI

✔

Protection

GFCI

✔

Protection

GFCI

✔

Protection

PB103-000

No GFCI

✔

Protection

No GFCI

✔

Protection

GFCI

✔

Protection

No GFCI

✔

Protection

Protection

Power Cords
Features Flexible, Abrasion-Resistant Construction Offering Reliable Performance to -31ºF
LENGTH

FACTORY-ASSEMBLED CORD SETS
BLACK FLEXIBLE CORD w/
YELLOW & WHITE
(3) #6 AWG and (1) #8
WEATHER-RESISTANT PLUG
AWG CONDUCTORS
NON-NEMA

YELLOW & WHITE
WEATHER-RESISTANT CONNECTOR
NON-NEMA

50A 125/250V, NON-NEMA
Y

50'
100'
†Consult

KRS-A9519
KUS-A9519

Y
X

EQ GR

X

W

NON-NEMA†

16.00
TER

CEN

MEET

TO

50A

125V/20A

125V/20A

in.
OUTL

OSHA

UTION

NON-NEMA†

Factory for Other Configurations.

125V/20A

in.
22

EQ GR
W

END VIEW 1

ETR

EMENTS
OUTDOO
CORD
REQUIR
LISTEDSUPPLY
125/250V
UL
USE POWER

RIB

DIST
E

Temporary Portable Power Distribution Center/GFCI & Power Cords

DIELECTRIC
VOLTAGE

SIDE VIEW 1

POW
RY

INLE

OSHA
TO

MEET

TEMPO

T

RA

R

ATION
ONLY.
NEL only.
INFORM
Shock, Use
PERSON center
.
SAFETY ED service f
and
el.
ed Rainproolocationsof Electic
of
Source
provided
QUALIFI
are
personn
Leg
BY authoriz e in damp the Risk
lt protected.
Supply
One
& 30A n for
USE by Enclosur
use
Defects
at the Position.
20A
Than .
for - To Reduce
Supplying
ground-fau
are
fault in
FORService 3R
Unit
Not More
protectio
TypeSuitable
This the Upright
usedGrounding of
if there Wiring
es rated
ground
fault 50A are
be
t
Protected Other
CAUTION
in
with
A 70.
Contact
Ground
or
Not
305-6(b)
OnlyAll receptacl
ground s rated
Who Are Not Provided
el must
Equipmen ANSI/NFP
Cord
provided
withReceptacle
is
Section
Circuit n
Persons
es not personn
the Protectio Extension
an Assuredby l Code,
for
in anthe Unit.receptacl n n with defined
Electrica
as
All protectio
250V/0.5A
conjunctio
National
Program
the Fuse Rating:

R

EMENTS
CORD
OUTDOO
REQUIR
LISTEDSUPPLY
125/250V
UL
USE POWER

50A

11BK

Cat.

/20A

GFCI
for
30A-2
RECE 50V
PTAC
LE

No.

POWERUNIT
UTION
Meet
to

Made

OSHA

Requirements

0A
V/2

-SGF
PB103

125

12 in.

LISTEDLE

PORTAB
DISTRIB

s Volts e
Amp 50
50 125/2 Hz, 4-Wir
60

125V

0A

V/3

250

250V/30A

12 in

.

TOP VIEW

n.
0i

.5

19

125V/20A

Weather Resistant Cover
For 30A Locking Recept.

END VIEW 2

To learn more about Leviton devices or for answers to technical questions call our Techline at

Circuit Breaker Cover

SIDE VIEW 2
1-800-824-3005 or visit us at:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

e

www.barr-thorp.com

www.leviton.com

F
8

GFCI Accessories
1 YEAR LIMITED

5977-CL

4992

5977-GY

4998-GY

5997-CL

5997-GY

Single-Gang Flush Cover Wallplates

GFCI Accessories

TYPE

Gray Die-Cast
Gray Die-Cast
Gray Die-Cast
Gray Die-Cast
Gray Die-Cast
Gray Die-Cast
Gray Plastic
White Plastic
Gray Plastic
White Plastic

MOUNTING POSITION

Zinc
Zinc
Zinc
Zinc
Zinc
Zinc

SINGLE-GANG
FLUSH COVER

Vertical
Horizontal
Vertical
Horizontal
Horizontal
Vertical
Horizontal
Horizontal
Vertical
Vertical

FITS
TYPE OF BOX

6196-V
6196
6196-VFS
6196-FS
4990
4992
4996-GY
4996-W
4998-GY
4998-W

Standard
Standard
FS (4 Screws)
FS (4 Screws)
Standard
Standard
Standard
Standard
Standard
Standard

Raintight While-In-Use Covers
TYPE

MOUNTING POSITION

Gray Plastic
Gray Plastic
Clear Plastic
Clear Plastic
Gray Plastic
Gray Plastic
Clear Plastic
Clear Plastic

3.30 (83.8 mm)

SINGLE-GANG
FLUSH COVER

FITS
TYPE OF BOX

Vertical
Vertical Mount w/
Extra Deep Cover
Vertical

5977-GY
5977-DGY

Vertical Mount w/
Extra Deep Cover
Horizontal
Horizontal Mount w/
Extra Deep Cover
Horizontal
Horizontal Mount w/
Extra Deep Cover

5977-DCL

Outdoor-Type Boxes

5997-GY
5997-DGY

or Flush-Mounted

Surface-Mounted

5977-CL

Wall Boxes

5997-CL
5997-DCL

3.75 (95.6 mm)

6.59 (167.4 mm)

5.46 (138.7 mm)

2.88 (73.2 mm)

Ø 0.63 (16.0 mm)
cord opening

Ø 0.25 (6.4 mm)
padlock opening

5.05 (128.3 mm)

F
9

Ø 0.25 (16.0 mm)
cord opening

5977

To learn more about Leviton devices or for answers to technical questions call our Techline at

5997

1-800-824-3005 or visit us at:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

e

www.barr-thorp.com

www.leviton.com

SmartLock PRO ™ Information
SmartLockPRO and The New 2006 UL943 GFCI Safety Standards
Underwriter’s Laboratories (UL) has issued new
requirements on GFCI functionality effective
July 28, 2006:
Line-Load Reversal Indication
If an old style GFCI is miswired with a line-load reversal, it
is a potentially hazardous situation because the GFCI
receptacle face will be live and unprotected even after the
GFCI is tripped.
2003 UL Standard:
• There must be a diagnostic indicator if a miswiring (lineload reversal) occurs during installation. However, the GFCI
receptacle’s face may still be live and unprotected.

New UL 2006 Standard:
• If a miswiring (line-load reversal) occurs during installation,
the GFCI must not be capable of supplying power to either
the GFCI’s face or to feed-through terminals.
• SmartLockPRO provides a true dead-face design with an
LED indicator for line-load reversals.

• There are no requirements related to “end of life”

New UL 2006 Standard:
• GFCIs are required to provide a visual and/or audible
indication OR be able to render themselves incapable of
delivering power when they no longer offer ground fault
protection based on a failure to pass their internal test.

The SmartLockPRO Solution:
• Though a standard GFCI CAN be reset even if it is not providing protection…the SmartLockPRO ’s reset button will
not engage if protection has been compromised. With
SmartLockPRO ’s unique patented professional grade end-oflife lock-out action you can avoid having a live, unprotected
receptacle in the event that the GFCI can no longer provide
protection. The robust design of SmartLockPRO GFCIs also
greatly reduces the frequency of GFCI failures, contributing to
a longer GFCI service life.

The Choice for 2006 UL End-of-Life Indication: Protection or No Protection?
Other GFCI manufacturers have taken the alternate route in
the 2006 UL Standard by providing an indicator light for endof-life indication. They allow the compromised GFCI to be
reset, thereby permitting it to continue delivering unprotected power to the GFCI face and downstream receptacles. We
disagree with this approach.
GFCIs are first and foremost proven safety devices. The
National Electrical Code requires GFCIs to be installed in
bathrooms, kitchens, workshops and other locations where
water is present and there’s a risk of ground fault shock

hazard. Leviton believes that a GFCI should be replaced
immediately if it no longer provides ground fault protection.
There is absolutely no people protection when a compromised GFCI functions as a “live” standard receptacle.
That’s why Leviton’s SmartLockPRO GFCI performs a selftest every time it is reset. If it is not capable of responding to
a ground fault, the reset is blocked. Leviton’s SmartLock
PRO approach locks out a compromised GFCI, thereby providing the safest and smartest solution to people protection.

SmartLockPRO ™ Information

The SmartLockPRO Solution:

“End-of-Life” Indication
GFCIs reach the end of their service life when they no
longer provide ground fault protection. As with any
electronic device, a GFCI can be damaged by surges,
other electrical disturbances, or environmental and
physical abuse.
2003 UL Standard:

General Testing Procedures
Non-Lockout Style GFCI

SmartLockPRO GFCI

Plug a lamp or radio into the GFCI receptacle.

Plug a lamp or radio into the GFCI receptacle.

Turn ON lamp or radio.

Turn ON lamp or radio.

Push the TEST button on the GFCI. If the GFCI is working
properly, it will trip and power to the lamp or radio will
be cut off. Push reset button to restore power.

Push the TEST button on the SmartLockPRO GFCI. The
GFCI will trip and power to the lamp or radio will be cut off.

Your GFCI is working properly and should be
retested every month.
If power did not go off:
If power did not go off when you pushed the TEST button,
then the GFCI is not providing protection and should be
replaced immediately. Standard GFCIs can still be reset
and provide power even though they are not providing
protection.

Your GFCI is working properly if you can push the RESET
button on the SmartLockPRO GFCI to restore power
to the lamp or radio.
IMPORTANT: The RESET button will not restore power if
the GFCI is damaged and cannot respond to a ground fault.

That’s why we developed SmartLockPRO…

To learn more about Leviton devices or for answers to technical questions call our Techline at

1-800-824-3005 or visit us at:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

e

www.barr-thorp.com

www.leviton.com

F
10



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : Tim
Title                           : Industrial Wiring Devices Full Line Catalog.pdf
Create Date                     : 2011:02:24 12:16:30
Creator Tool                    : Adobe Acrobat 10.0.1
Modify Date                     : 2011:04:08 11:27:06-06:00
Metadata Date                   : 2011:04:08 11:27:06-06:00
Producer                        : GPL Ghostscript 8.15
Document ID                     : uuid:2b1ba9ad-bbe3-43c7-a461-785f9f6f2b08
Instance ID                     : uuid:52107093-bb5c-4654-b6b0-8adbfe1cb794
Page Count                      : 11
Author                          : Tim
EXIF Metadata provided by EXIF.tools

Navigation menu