Industrial Wiring Devices Full Line Catalog 139354

2016-10-27

: Pdf 139354-Catalog 139354-Catalog B6 unilog

Open the PDF directly: View PDF PDF.
Page Count: 11

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
SmartLock
PRO
GFCI Devices
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: ewww.leviton.com
SmartLock
PRO
GFCI devices comply with 2006 UL requirements
• Power/Diagnostic
Indicator
• 15 & 20 Amp
Configurations
• Back and Side Wired
Color Match
Test/Reset Buttons
(Monochromatic)
Resistant to Surge,
Noise, and Corrosion
Per 2006 UL
Requirements
6" leads ideal for OEM
applications
PAGE F3
HOSPITAL GRADE COMMERCIAL GRADE COMMERCIAL GRADE
w/Wire Leads
BLANK FACE COMBO HIGH CURRENT
PANEL MOUNTS WORK LIGHT ANGLE PLUGS
15 Amp Single GFCI
Receptacle with
Single-Pole Switch
Switch Rated 15A at
120V AC
Back and Side Wired
Color Match
Test/Reset Buttons
(Monochromatic)
Resistant to Surge,
Noise, and Corrosion
Per 2006 UL
Requirements
PAGE F3
Fluorescent Work Light with GFCI
Protected Receptacle
• 13 Watt Lamp and Receptacle
• Black Body with 20' Yellow Cord 16/3 SJTW
• NEMA 5-15R Receptacle; NEMA 5-15P Plug
• Automatic Reset In-Line GFCI with Power
Status Indicator
PAGE F4
20 Amp with Switch
Rated Test/ Reset
Buttons
Back and Side Wired
Color Match
Test/Reset Buttons
(Monochromatic)
Resistant to Surge,
Noise, and Corrosion
Per 2006 UL
Requirements
PAGE F3
Panel Mount GFCI with 16" Leads
20A 125V
Orange LED Indicator Light
Weather-Resistant Housing &
Test/Reset Buttons
Resistant to Surge, Noise, and
Corrosion Per 2006 UL Requirements
PAGE F4
• Power/Diagnostic
Indicator
15 & 20Amp
Configurations
Back and Side Wired
Color Match
Test/Reset Buttons
(Monochromatic)
Green LED Indicates
Power and Confirms
Proper Wiring Status
Resistant to Surge,
Noise, and Corrosion
Per 2006 UL
Requirements
PAGE F3, Section H
Blank Face
Contact Rating:
20A 125V
Control Relay: 80 Amps
240VAC Max.
Side Wired
Color Match Test/Reset
Buttons (Monochromatic)
Resistant to Surge,
Noise, and Corrosion
Per 2006 UL Requirements
PAGE F4
• Power/Diagnostic
Indicator
• 15 & 20 Amp
Configurations
• Back and Side Wired
Color Match
Test/Reset Buttons
(Monochromatic)
Resistant to Surge,
Noise, and Corrosion
Per 2006 UL
Requirements
PAGE F3
“THE BOX”
• 6 GFCI Protected 20A 125V Straight
Blade or Locking Receptacles
• GFCI Protected 30A 250V Locking Receptacle
• 50A 125/250V Non-NEMA Power Connections
• Meets OSHA Regulation 20, Subpart K
Standards
• UL Listed for Outdoor Use
PAGE F8
GFCI Cord Sets
15A & 20A 125V; 15A & 20A 240V
Automatic and Manual Reset Types
Orange Power Status Indicator
Yellow Cord 14/3 SJT
Resistant to Surge, Noise, & Corrosion
Per 2006 UL Requirements
PAGES F6 & F7
Right Angle GFCI Plugs
15A 125V; 20A 125V
Automatic and Manual
Reset Types
Power Status Indicator
Available in Dark Gray
and Yellow
Consult factory for
availability
PAGE F4
7899-HGR 7599-T 7599-LW
7590-W 7299-A 8895-80E
36596 66591-WL
Recognized
Component
66591-25C PB101-SGF Effective July 28, 2006
See Page F10
for Full Details
16593
Recognized
Component
Recognized
Component
NEW UL943 GFCI
CORD SETS POWER CENTER SAFETY STANDARDS
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
SmartLock
PRO
GFCI Features
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: e
www.leviton.com
Leviton SmartLock
PRO
icon
ensures improved GFCI
product design.
Lockout action blocks the “RESET”
button if GFCI protection has been
compromised.
UL Standard 943 Class A (GFCI) & 498 (Receptacles)
CSA Certified (File #057)
Meets July 28, 2006 UL Requirements
Triple combination
terminal screws.
“Surge hardened” electronics
offer superior resistance to
surges and overvoltages.
LED power indicator light helps
diagnose improper wiring and,
when illuminated, offers visual
confirmation that power is
available.
Heavy duty double wipe for
15 Amp contacts and triple
wipe for 20 Amp contacts
Patented lockout feature prevents
“RESET” if GFCI is not functioning
properly or miswired due to reversal of
line and load leads.
Thick-walled, impact-resistant
thermoplastic nylon cover and
body withstands abuse
Silver alloy contacts for reliable
make/break switching.
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL 943 CSA NOM
WD1&WD6 C-73 Listed Class A & 498
U U #E48380 U#LR-57811 #057
Eight back-wire holes
(two per terminal) and
back-wire ground.
Provisions for back-
or side-wiring.
COMPONENT DESCRIPTION
Face Nylon
Back Polycarbonate
Line Contacts Brass
Terminal Screws Brass #8-32
Grounding Screw Brass #8-32
Yoke Zinc Steel
Clamp Nuts Steel
Internal Contacts Silver Alloy
Leviton SmartLock
PRO
and The New 2006
UL943 GFCI Safety Standards
Line-Load Reversal Indication
New UL 2006 Standard:
If a miswiring (line-load reversal) occurs during installation,
the GFCI must not be capable of supplying power to either
the GFCI’s face or to feed-through terminals.
“End-of-Life” Indication
New UL 2006 Standard:
GFCIs are required to provide a visual and/or audible
indication OR be able to render themselves incapable of
delivering power when they no longer offer ground fault
protection based on a failure to pass their internal test.
For additional details on these new requirements, see page F10.
Dual function LED offers indication
of line/load reversal &
power availability.
7599-W
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
15A 125V & 20A 125V
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: ewww.leviton.com
Hospital & Commercial Grade, GFCI’s
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMMODATION I.D.
Brass, hot
Grounding
Silver, neutral
15A 125V, NEMA 5-15R; 20A 125V Feed-Through
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands 2kA
1500V
per
UL 498
80ºC max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC appl.
per UL 498
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -35ºC to 65ºC
Ratings
permanently
marked
on device
#14 - #12 AWG
solid or stranded
copper wire
7899-HG SERIES 7599 SERIES 7590 SERIES 7299 SERIES
4.21 (106.93 mm)
3.70 (93.98 mm)
1.31
0.94
3.81 (96.77 mm)
3.28 (83.81 mm)
2.74 (69.60 mm)
2.62 (66.55 mm)
1.19
0.29 (7.37 mm)
(23.88 mm)
(33.27 mm)
(30.23 mm)
7590-W
7599-I
Back & Side Wired
TRIP LEVEL
5±1 mA
7599-LI
20A 125V, NEMA 5-20R at Receptacle & Feed-Through
7899-HGR
3.81 (96.77 mm)
3.28 (83.81 mm)
2.74 (69.60 mm)
2.62 (66.55 mm)
1.19
0.29 (7.37 mm)
4.21 (106.93 mm)
3.70 (93.98 mm)
0.94
1.31
(30.23 mm)
(23.88 mm)
(33.27 mm) 1.7 (43.2 mm)
1.12 (28 mm)
2.7 (68.6 mm)
4.21 (106.93 mm)
CLASS A
LEVITON
GFCI CLASS
20 AMP
125V
1.53 (38.9 mm) 1.7 (43.2 mm)
1.12 (28 mm)
2.7 (68.6 mm)
4.21 (106.93 mm)
GFCI
1.53 (38.9 mm)
SHALLOW WALLBOX
COLOR EXTENDER
FOR GFCI's
Brown 6197
Ivory 6197-I
White 6179-W
7299-A
15A 125V, NEMA 5-15R;
20A 125V Feed-Through
#LR-57811 #057
MISC. MOTOR CONTROL RATING
15A-1875W
20A-2500W
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL CSA NOM
WD-6 C-73 943 Fed Spec C22.2
Class A Listed
& 498 WC-596
U U U
FACE GFCI COMBO DEVICE RECEPTACLE
COLOR & SINGLE-POLE SWITCH
Meets 2006 UL Requirements
Ivory 7299-I
White 7299-W
Almond 7299-A
GFCI GFCI GFCI GFCI
HOSPITAL GRADE COMMERCIAL GRADE COMMERCIAL GRADE COMMERCIAL GRADE
FACE SMARTLOCK
PRO
SMARTLOCK
PRO
SMARTLOCK
PRO
BLANK FACE
COLOR DUPLEX w/ LED DUPLEX w/ LED DUPLEX w/ LED S-P SWITCH
w/ 6" Leads. 1.5HP@120V AC
Meets 2006 Meets 2006 Meets 2006 Meets 2006
UL Requirements UL Requirements UL Requirements UL Requirements
Brown 7599-HG 7599
– –
Ivory 7599-HGI 7599-I 7599-LI 7590-I
White 7599-HGW 7599-W 7599-LW 7590-W
Gray 7599-HGG 7599-G
– –
Red 7599-HGR 7599-R
– –
Black
7599-E
7590-E
Almond 7599-HGA 7599-A
7590-A
Lt. Almond 7599-HGT 7599-T
7590-T
Brown 7899-HG 7899
– –
Ivory 7899-HGI 7899-I 7899-LI
White 7899-HGW 7899-W 7899-LW
Gray 7899-HGG 7899-G
– –
Red 7899-HGR
– – –
Black 7899-HGE 7899-E
– –
Almond 7899-HGA 7899-A
– –
Lt. Almond 7899-HGT 7899-T
– –
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
15A 125V & 20A 125V
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: e
www.leviton.com
Commercial Grade, GFCI’s
GFCI-Protected Fluorescent Work Light w/Receptacle
15A 125V, 2-P 3-W Grounding
LENGTH GFCI CORD SET, YELLOW CORD, 16/3 SJTW NEMA NEMA
BLACK BODY, ON/OFF POWER SWITCH, PLUG CONNECTOR
13 WATT LAMP
20’ 66591-WL 5-15P 5-15R
G
W
G
W
PANEL MOUNT FOR TEMPORARY
POWER DISTRIBUTION BOXES
36597
PANEL MOUNT GFCI FOR
PHASE-CONTROL THEATER
DIMMING SYSTEMS
36895
TOGGLE BLANK FACE
COLOR RESET BUTTONS
Ivory 8895-80I
White 8895-80W
Black 8895-80E
16893 16594
COLOR WATERPROOF COVER
WITH GROUND PIN UP
ORIENTATION
Clear 86593
Right Angle Plugs Accessory
20A 125V, NEMA 5-20P
15A 125V, NEMA 5-15P
Right Angle GFCI Plugs
30ºC max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498
Ratings
permanently
marked
on device
#18- #12 AWG
#LR-57811 #057
MISC. MOTOR CONTROL RATING
15A-1875W
20A-2500W
TRIP LEVEL
5±1 mA
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -35ºC to 66ºC
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL CSA NOM
WD-6 C-73 943 Fed Spec C22.2
Class A Listed
& 498 WC-596
U U U
Recognized Component*
Recognized Component
High Current GFCI
Contact Rating: 20A 125V AC
Load Capability with 125V Control Relay
80@240V AC Max.
36596, 36597, 36895 RIGHT ANGLE GFCI PLUGS 8895
~~~~~~~
~~~~~~
~~~~~~~
TEST
RESE
1.74 (44.2 mm)
3.8 (96.5 mm)
2.7 (68.6 mm)
2.40 (64 mm)
4.75 (121 mm)
5.12 (130 mm)
1.29 DIA.
(33 mm)
1.60 DIA.
(41 mm)
1.83 DIA.
(49 mm)
.023 REF.
1.7 (43.2 mm)
1.12 (28 mm)
2.7 (68.6 mm)
4.21 (106.93 mm)
15A 125V
RECEPTACLE
CLASS A
LEVITON
GFCI CLASS
20 AMP
125V
1.26 (32 mm)
OFF
ON
SWITCH
RESET
RESET
FOLLOW DIRECTIONS
SUIVEZ INSTRUCTION
TEST MONTHLY
TEST MENSUEL
TEST
TEST
GROUND FAULT CIRCUIT
INTERRUPTER-MISC. MOTOR
CONTROLLER AND SWITCH
1.77 (45 mm)
2.58 (65.5 mm)
.810
(20.6 mm)
Recognized Component
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMMODATION I.D.
Brass, hot
Grounding
Silver, neutral
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands 2kA
1500V
per
UL 498
Front View Side View
16593
PLUG ANGLE PLUG ANGLE PLUG
COLOR AUTOMATIC MANUAL AUTOMATIC MANUAL
RESET RESET RESET RESET
Black 16593 16893
Yellow – 16594 16894
Wiring Termination Area
Rated 20A-125 VAC
*Catalog numbers 6593, 6893, 6594 and 6894 series are available – consult factory. For additional information,
see catalog L-100, page H5.
Refer to footnote
under Right Angle
GFCI Plugs Table
86593
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
Available in 2-ft., 6-ft. and 25-ft.
lengths, except where indicated
RTV injected at cord entrance and
exit of the housing
Choice of Automatic or Manual
reset models
GFCI Cord Set Features
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: ewww.leviton.com
Power indicator light goes OFF if
GFCI trips, power is interrupted
or line cord is unplugged
GFCI Cord Set Features
Water-resistant enclosure sealed
by ultrasonic welding to ensure
long service life
Equipped with Industrial Grade plugs and
connectors to provide long service life in
heavy-duty applications
Water-resistant SJTW-A cable
(14/3 for 15A, 12/3 for 20A)
Agency Standards
Complies with UL Standard 943 as a
Recognized Component Class A GFCI
power supply with open neutral protection
UL Listed (File #E-48380), 15A devices also
CSA Certified (File #LR-5781)
Fully complies with NEC code article #527.6,
6(A) and 6(B) and OSHA regulation CFR
1926-404b(i)(ii) for construction sites
In-line GFCI units are NEMA 3R
GFCI Protection: An OSHA Requirement on the Job Site
OSHA definitely means business, with fines for willful violations reaching as high as $70,000! The second
most common OSHA electrical violation at construction sites involves non-compliance with either the
Assured Equipment Grounding Program or Ground Fault Protection. Whichever program you choose,
portable GFCI Cord Sets or an approved grounding conductor program, make sure it is used 100% of the
time. Ignoring OSHA requirements can cost money as well as business. Compliance with OSHA and NEC
standards is absolutely mandatory, and use of Leviton GFCI Cord Sets is a reliable, economical way to
accomplish that.
GFCI Cord Sets Must Have Open-Neutral Protection
Open-Neutral Protection immediately trips the GFCI if the neutral conductor on the line side is opened.
This eliminates the possibility of the GFCI Cord Set having a live hot leg, even though it may appear as
though power is off due to the open neutral. A normal GFCI receptacle would not be able to trip under
these conditions.
Automatic vs. Manual Reset Cord Sets
Automatic Reset GFCI Cord Sets (black body) automatically reset ON when power is restored. Manual Reset
units (yellow body) will not automatically reset after power interruption; the reset button must be pushed in.
Automatic Reset GFCI Cord Sets and Extension Cords Black Body
Automatically resets to ON when plugged in or after power interruption
Available in 2-ft, 6-ft and 25-ft lengths except where indicated
Cat. No. 66591-WL
Provides lighting and GFCI protection in
out-of-the-way locations
Manual Reset GFCI Cord Sets with
Wetguard®plugs and connectors provide
outstanding corrosion-resistance where
water is present
Custom lengths and configurations
available as special order
69593-3
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
15A 125V&250V;20A 125V&250V
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: e
www.leviton.com
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands 2kA
1500V
per
UL 498
GFCI CORD SET AUTOMATIC RESET
LENGTH (15 AMP) 14/3 SJTW NEMA NEMA
(20 AMP) 12/3 SJTW PLUG CONNECTOR
YELLOW CORD, BLACK BODY
BLACK PLUG & CONNECTOR
66891-3 66593-3
5-15P 5-15R
5-15P 5-15R
L5-15P L5-15R
5-15P
6-15P
5-20P 5-20R
L5-20P L5-20R
15A 125V, Cord Sets
15A 240V, Power Supply Cord
20A 125V, Cord Sets
20A 125V, Locking Cord Set
15A 125V, Power Supply Cord
15A 125V, Locking Cord Set
15A 125V, Cord Set Triple Outlet
20A 125V, Power Supply Cord
5-20P
20A 240V, Power Supply Cord
6-20P
Automatic reset GFCI cord sets (black body) automatically reset ON when power is restored.
66591-25C
30ºC max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498
Ratings
permanently
marked
on device
Not Applicable
TRIP LEVEL
5±1 mA
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -35ºC to 66ºC
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMMODATION I.D.
Brass, hot
Grounding
Silver, neutral
FACTORY-ASSEMBLED CORD SETS — Consult Techline for changes in length and/or configurations.
2' 66591-2C
6' 66591-6C
25' 66591-25C
3' 66593-3
3' 66597-3
37' 26591-37C
35' 26592-E
3' 66891-3
3' 66897-3
37' 36591-37C
35' 36592-E
#LR-57811 #057
MISC. MOTOR CONTROL RATING
15A-1875W
20A-2500W
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL CSA NOM
WD-6 C-73 943 Fed Spec C22.2
Class A Listed
& 498 WC-596
U U U
Automatic Reset GFCI Cord Sets & Power Supply Cords
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
15A 125V;20A 125V
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: ewww.leviton.com
Manual Reset GFCI Cord Sets
GFCI CORD SET MANUAL RESET
LENGTH (15 AMP) 14/3 SJTW NEMA NEMA
(20 AMP) 12/3 SJTW PLUG CONNECTOR
YELLOW CORD,YELLOW BODY
YELLOW PLUG & CONNECTOR
5-15P 5-15R
5-15P 5-15R
5-20P 5-20R
15A 125V, Cord Sets
20A 125V, W/ Wetguard Plug & Connector Cord Set
15A 125V, W/ Wetguard Plug & Connector Cord Set
15A 125V, Cord Set Triple Outlet
5-15P 5-15R
36.0 (914.4 mm)
1.63 (41.1 mm)
6.70 (170.2 mm)
1.78 (45.2 mm)
2.50 (63.5 mm)
0.63 (15.6 mm)
MANUAL RESET GFCI CORD
69591-W3
TESTRESET
TEST RESET
FOLLOW DIRECTIONS
TEST BEFORE EACH USE
6.70 (170.2 mm)
(9.32 ± 2 mm) 2.50 (63.5 mm)
0.367± 0.07
15A AUTO GFCI CORD
66591-2C — on page F6
Manual reset units (yellow body) will not automatically reset
after power interruption; the reset button must be pushed in.
69591-W3 69891-3
30ºC max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498
Ratings
permanently
marked
on device
Not Applicable
TRIP LEVEL
5±1 mA
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -35ºC to 66ºC
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMMODATION I.D.
Brass, hot
Grounding
Silver, neutral
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands 2kA
1500V
per
UL 498
#LR-57811 #057
MISC. MOTOR CONTROL RATING
15A-1875W
20A-2500W
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL CSA NOM
WD-6 C-73 943 Fed Spec C22.2
Class A Listed
& 498 WC-596
U U U
FACTORY-ASSEMBLED CORD SETS - Consult Techline for changes in length and/or configurations.
3' 69591-3
25' 69591-25
3' 69593-3
3' 69591-W3
25' 69591-W25
3' 69891-W3
69593-3 69591-W3
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
50A 125/250V
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: e
www.leviton.com
Power Center “THE BOX” & Power Cords
LENGTH BLACK FLEXIBLE CORD w/ YELLOW & WHITE YELLOW & WHITE
(3) #6 AWG and (1) #8 WEATHER-RESISTANT PLUG WEATHER-RESISTANT CONNECTOR
AWG CONDUCTORS NON-NEMA NON-NEMA
50' KRS-A9519
100' KUS-A9519
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands 2kA
1500V
per
UL 498
FACTORY-ASSEMBLED CORD SETS
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -35ºC to 66ºC
Ratings &
NEMA I.D.
permanently
marked on device
Not Applicable
Power Cords
Features Flexible, Abrasion-Resistant Construction Offering Reliable Performance to -31ºF
EQ GR
X
Y
W
NON-NEMANON-NEMA
50A 125/250V, NON-NEMA
22 in.22 in.
12 in.
19.50 in.
12 in.
16.00 in.
OUTLET
125/250V
TO MEET OSHA REQUIREMENTS
50A
USE UL LISTED OUTDOOR
POWER SUPPLY CORD
R
T
POWER SUPPLY CORD
USE UL LISTED OUTDOOR
50A
TO MEET OSHA REQUIREMENTS
125/250V
INLET
EMPORARY
P
OWE
D
ISTRIBUTION
C
ENTER
250V/30A
125V/20A
125V/20A
GFCI
for
30A-250V
RECEPTACLE
60Hz, 4-Wire
125/250 Volts
50 Amps
DISTRIBUTION UNIT
PORTABLE POWER
LISTED
11BK
Cat.No. PB103-SGF
OSHA
MadetoMeet
Requirements
Receptaclesrated50A are Not ground-faultprotected.
PersonsWhoContact More Than One Leg of
theNationalElectrical Code, ANSI/NFPA 70.
Programasdefined by Section 305-6(b) of
conjunctionwithan Assured Equipment Grounding
protection for personnel must be used in
All receptacles not provided with groundfault
Suitableforuse in damp locations.
SAFETYINFORMATION
FOR USE BYQUALIFIEDPERSONNELONLY.
CAUTION- ToReduce the Risk of Electic Shock,
Ground This Unit at the Supply Source and Use
Onlyinthe Upright Position.
All receptacles rated 20A& 30Aare provided
withgroundfaultprotectionfor personnel.
theCircuitAre Not Protected.
ProtectionisNot Provided if there are Defects
inanExtension Cord or Other Wiring Supplying
theUnit.
Type 3R Enclosure - Rainproof
Servicebyauthorized service center only.
FuseRating:250V/0.5A
125V/20A 125V/20A 125V/20A
250V/30A250V/30A 125V/20A125V/20A
Weather Resistant Cover
For 30A Locking Recept. Circuit Breaker Cover
END VIEW 1 SIDE VIEW 1
TOP VIEW END VIEW 2 SIDE VIEW 2
30ºC max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498
TRIP LEVEL
5±1 mA
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMMODATION I.D.
Brass, hot
Grounding
White,neutral #LR-57811 #057
OSHA
“The Box” Meets Regulation 20, Part 1926,
Subpart K Standards
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL CSA NOM
WD-6 C-73 943 Fed Spec C22.2
Class A Listed
& 498 WC-596
U U U
Consult Factory for Other Configurations.
Power Distribution Box
Available with or without GFCI Protection on 30A Receptacles Consult Factory for Other Configurations
Power Inlet Power Outlet 6 NEMA Locking 6 NEMA Straight 1 NEMA Locking
Catalogue No. Non-NEMA Non-NEMA Receptacles Blade Receptacles Receptacle
50A, 125/250V 50A, 125/250V 20A, 125V, L5-20R 20A, 125V, 5-20R 30A, 250V, L6-30R
✔ ✔
✔ ✔
✔ ✔
✔ ✔
No GFCI Protection
No GFCI Protection
No GFCI Protection
No GFCI Protection
No GFCI Protection
No GFCI Protection
No GFCI Protection
No GFCI Protection
GFCI Protection
GFCI Protection
GFCI Protection
GFCI Protection
GFCI Protection
No GFCI Protection
No GFCI Protection
GFCI Protection
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
GFCI Accessories
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: ewww.leviton.com
Single-Gang Flush Cover Wallplates
Raintight While-In-Use Covers
Surface-Mounted
Outdoor-Type Boxes
or Flush-Mounted
Wall Boxes
5977-CL 5977-GY 4992 4998-GY 5997-GY 5997-CL
3.75 (95.6 mm)
6.59 (167.4 mm)
3.30 (83.8 mm)
Ø 0.25 (16.0 mm)
cord opening
5977
5.05 (128.3 mm)
Ø 0.25 (6.4 mm)
padlock opening
5.46 (138.7 mm)
2.88 (73.2 mm)
Ø 0.63 (16.0 mm)
cord opening
5997
TYPE MOUNTING POSITION SINGLE-GANG FITS
FLUSH COVER TYPE OF BOX
Gray Die-Cast Zinc Vertical 6196-V Standard
Gray Die-Cast Zinc Horizontal 6196 Standard
Gray Die-Cast Zinc Vertical 6196-VFS FS (4 Screws)
Gray Die-Cast Zinc Horizontal 6196-FS FS (4 Screws)
Gray Die-Cast Zinc Horizontal 4990 Standard
Gray Die-Cast Zinc Vertical 4992 Standard
Gray Plastic Horizontal 4996-GY Standard
White Plastic Horizontal 4996-W Standard
Gray Plastic Vertical 4998-GY Standard
White Plastic Vertical 4998-W Standard
TYPE MOUNTING POSITION SINGLE-GANG FITS
FLUSH COVER TYPE OF BOX
Gray Plastic Vertical 5977-GY
Gray Plastic Vertical Mount w/ 5977-DGY
Extra Deep Cover
Clear Plastic Vertical 5977-CL
Clear Plastic Vertical Mount w/ 5977-DCL
Extra Deep Cover
Gray Plastic Horizontal 5997-GY
Gray Plastic Horizontal Mount w/ 5997-DGY
Extra Deep Cover
Clear Plastic Horizontal 5997-CL
Clear Plastic Horizontal Mount w/ 5997-DCL
Extra Deep Cover
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
SmartLock
PRO
Information
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: e
www.leviton.com
Other GFCI manufacturers have taken the alternate route in
the 2006 UL Standard by providing an indicator light for end-
of-life indication. They allow the compromised GFCI to be
reset, thereby permitting it to continue delivering unprotect-
ed power to the GFCI face and downstream receptacles. We
disagree with this approach.
GFCIs are first and foremost proven safety devices. The
National Electrical Code requires GFCIs to be installed in
bathrooms, kitchens, workshops and other locations where
water is present and there’s a risk of ground fault shock
hazard. Leviton believes that a GFCI should be replaced
immediately if it no longer provides ground fault protection.
There is absolutely no people protection when a compro-
mised GFCI functions as a “live” standard receptacle.
That’s why Levitons SmartLock
PRO
GFCI performs a self-
test every time it is reset. If it is not capable of responding to
a ground fault, the reset is blocked. Levitons SmartLock
PRO
approach locks out a compromised GFCI, thereby pro-
viding the safest and smartest solution to people protection.
Underwriter’s Laboratories (UL) has issued new
requirements on GFCI functionality effective
July 28, 2006:
Line-Load Reversal Indication
If an old style GFCI is miswired with a line-load reversal, it
is a potentially hazardous situation because the GFCI
receptacle face will be live and unprotected even after the
GFCI is tripped.
2003 UL Standard:
There must be a diagnostic indicator if a miswiring (line-
load reversal) occurs during installation. However, the GFCI
receptacle’s face may still be live and unprotected.
New UL 2006 Standard:
If a miswiring (line-load reversal) occurs during installation,
the GFCI must not be capable of supplying power to either
the GFCI’s face or to feed-through terminals.
The SmartLockPRO Solution:
• SmartLock
PRO
provides a true dead-face design with an
LED indicator for line-load reversals.
“End-of-Life” Indication
GFCIs reach the end of their service life when they no
longer provide ground fault protection. As with any
electronic device, a GFCI can be damaged by surges,
other electrical disturbances, or environmental and
physical abuse.
2003 UL Standard:
There are no requirements related to “end of life”
New UL 2006 Standard:
GFCIs are required to provide a visual and/or audible
indication OR be able to render themselves incapable of
delivering power when they no longer offer ground fault
protection based on a failure to pass their internal test.
The SmartLockPRO Solution:
Though a standard GFCI CAN be reset even if it is not pro-
viding protection…the SmartLock
PRO
s reset button will
not engage if protection has been compromised. With
SmartLock
PRO
s unique patented professional grade end-of-
life lock-out action you can avoid having a live, unprotected
receptacle in the event that the GFCI can no longer provide
protection. The robust design of SmartLock
PRO
GFCIs also
greatly reduces the frequency of GFCI failures, contributing to
a longer GFCI service life.
SmartLock
PRO
and The New 2006 UL943 GFCI Safety Standards
Non-Lockout Style GFCI SmartLock
PRO
GFCI
Plug a lamp or radio into the GFCI receptacle. Plug a lamp or radio into the GFCI receptacle.
Turn ON lamp or radio. Turn ON lamp or radio.
Push the TEST button on the GFCI. If the GFCI is working Push the TEST button on the SmartLock
PRO
GFCI. The
properly, it will trip and power to the lamp or radio will GFCI will trip and power to the lamp or radio will be cut off.
be cut off. Push reset button to restore power.
Your GFCI is working properly and should be
retested every month.
If power did not go off: Your GFCI is working properly if you can push the RESET
If power did not go off when you pushed the TEST button, button on the SmartLock
PRO
GFCI to restore power
then the GFCI is not providing protection and should be to the lamp or radio.
replaced immediately. Standard GFCIs can still be reset
and provide power even though they are not providing IMPORTANT: The RESET button will not restore power if
protection. the GFCI is damaged and cannot respond to a ground fault.
That’s why we developed SmartLock
PRO
The Choice for 2006 UL End-of-Life Indication: Protection or No Protection?
General Testing Procedures
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com

Navigation menu