1408123 509510 CE REPORT
2016-04-11
: Pdf 1408123-509510-Ce Report 1408123-509510-CE_REPORT CertsReports 509510 ProductFiles
Open the PDF directly: View PDF
.
Page Count: 67
| Download | |
| Open PDF In Browser | View PDF |
CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 EMC TEST REPORT Authorized under Declaration of Conformity According to EN 55022 : 2010 / AC:2011 EN 61000-3-2: 2006+A2: 2009 EN 61000-3-3 : 2008 EN 55024 : 2010 IEC 61000-4-2 : 2008 IEC 61000-4-3 : 2006+A1:2007+A2:2010 IEC 61000-4-4 : 2012 IEC 61000-4-5 : 2005 IEC 61000-4-6 : 2008 IEC 61000-4-8 : 2009 IEC 61000-4-11 : 2004 Applicant : Intracom Asia Co., Ltd Address : Equipment : Fast Ethernet PCI Network Card Model No. : 509510 Trademark : Intellinet 4F., No.77, Sec.1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221, Taiwan The test result refers exclusively to the test presented test model / sample. Without written approval of Cerpass Technology (Suzhou) Corp. the test report shall not be reproduced except in full. This test report is only applicable to European Community. The test report must not be used by the clients to claim product certification approval by NVLAP or any agency of the Government. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 1 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 Contents CERTIFICATE OF COMPLIANCE ....................................................................... 5 1. Summary of Test Procedure and Test Results .................................................... 6 2. Immunity Testing Performance Criteria Definition ................................................ 6 3. Test Configuration of Equipment under Test ...................................................... 7 3.1. Factory ............................................................................................................................................. 7 3.2. Feature of Equipment under Test..................................................................................................... 7 3.3. Test Manner ..................................................................................................................................... 7 3.4. Description of Test System............................................................................................................... 8 3.5. General Information of Test.............................................................................................................. 9 3.6. Measurement Uncertainty ................................................................................................................ 9 4. Test of Conducted Emission........................................................................10 4.1. Test Limit ........................................................................................................................................ 10 4.2. Test Procedures ............................................................................................................................. 11 4.3. Typical Test Setup .......................................................................................................................... 11 4.4. Measurement equipment ............................................................................................................... 12 4.5. Test Data and Result...................................................................................................................... 13 4.6. Test Photographs ........................................................................................................................... 17 5. Test of Radiated Emission .........................................................................19 5.1. Test Limit ........................................................................................................................................ 19 5.2. Test Procedures ............................................................................................................................. 20 5.3. Typical test Setup........................................................................................................................... 21 5.4. Measurement equipment ............................................................................................................... 22 5.5. Test Result and Data (30MHz ~ 1000MHz) ................................................................................... 23 5.6. Test Result and Data (1000MHz ~ 6000MHz) ............................................................................... 25 5.7. Test Photographs (30MHz ~ 1000MHz)......................................................................................... 27 5.8. Test Photographs (1000MHz ~ 6000MHz)..................................................................................... 28 6. Harmonics Test .....................................................................................29 6.1. Limits Of Harmonics Current Measurement................................................................................... 29 6.2. Measurement equipment ............................................................................................................... 29 6.3. Test Result and Data...................................................................................................................... 30 6.4. Test Photographs ........................................................................................................................... 34 7. Voltage Fluctuations Test ..........................................................................35 7.1. Test Procedure ............................................................................................................................... 35 7.2. Measurement equipment ............................................................................................................... 35 7.3. Test Result and Data...................................................................................................................... 36 7.4. Test Photographs ........................................................................................................................... 38 8. Electrostatic Discharge Immunity Test ...........................................................39 8.1. Test Procedure ............................................................................................................................... 39 8.2. Test Setup for Tests Performed in Laboratory................................................................................ 40 8.3. Test Severity Levels ....................................................................................................................... 41 8.4. Measurement equipment ............................................................................................................... 41 8.5. Test Result and Data...................................................................................................................... 42 Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 2 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 8.6. Test Photographs ........................................................................................................................... 43 9. Radio Frequency electromagnetic field immunity test............................................44 9.1. Test Procedure ............................................................................................................................... 44 9.2. Test Severity Levels ....................................................................................................................... 45 9.3. Measurement equipment ............................................................................................................... 45 9.4. Test Result and Data...................................................................................................................... 46 9.5. Test Photographs ........................................................................................................................... 47 10. Electrical Fast Transient/ Burst Immunity Test .................................................48 10.1. Test Procedure............................................................................................................................ 48 10.2. Test Severity Levels .................................................................................................................... 49 10.3. Measurement equipment ............................................................................................................ 49 10.4. Test Result and Data................................................................................................................... 50 10.5. Test Photographs ........................................................................................................................ 51 11. Surge Immunity Test ...............................................................................52 11.1. Test Procedure............................................................................................................................ 52 11.2. Test Severity Level...................................................................................................................... 53 11.3. Measurement equipment ............................................................................................................ 53 11.4. Test Result and Data................................................................................................................... 54 11.5. Test Photographs ........................................................................................................................ 55 12. Conduction Disturbances induced by Radio-Frequency Fields....................................56 12.1. Test Procedure............................................................................................................................ 56 12.2. Test Severity Levels .................................................................................................................... 57 12.3. Measurement equipment ............................................................................................................ 57 12.4. Test Result and Data................................................................................................................... 58 12.5. Test Photographs ........................................................................................................................ 59 13. Power Frequency Magnetic Field Immunity Tests ................................................60 13.1. Test Setup ................................................................................................................................. 60 13.2. Test Severity Levels .................................................................................................................... 60 13.3. Measurement equipment ............................................................................................................ 60 13.4. Test Result and Data................................................................................................................... 61 14. Voltage Dips and Voltage Interruptions Immunity Test Setup ..................................62 14.1. Test Conditions ........................................................................................................................... 62 14.2. Measurement equipment ............................................................................................................ 62 14.3. Test Result and Data................................................................................................................... 63 14.4. Test Photographs ........................................................................................................................ 64 15. Photographs of EUT ................................................................................65 Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 3 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 History of this test report Original Additional attachment as following record: Attachment No. Date Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Description Issued Date : Oct.31, 2014 Page No. : 4 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 CERTIFICATE OF COMPLIANCE According to EN 55022 : 2010 / AC:2011 EN 61000-3-2: 2006+A2: 2009 EN 61000-3-3 : 2008 EN 55024 : 2010 IEC 61000-4-2 : 2008 IEC 61000-4-3 : 2006+A1:2007+A2:2010 IEC 61000-4-4 : 2012 IEC 61000-4-5 : 2005 IEC 61000-4-6 : 2008 IEC 61000-4-8 : 2009 IEC 61000-4-11 : 2004 Applicant : Intracom Asia Co., Ltd Address : Equipment : Fast Ethernet PCI Network Card Model No. : 509510 Trademark : Intellinet 4F., No.77, Sec.1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221, Taiwan I HEREBY CERTIFY THAT : The measurements shown in this test report were made in accordance with the procedures given in EUROPEAN COUNCIL DIRECTIVE 2004/108/EC& 2014/30/EU. The test was carried out on Oct .23~31, 2014 at Cerpass Technology(Suzhou) Corp. Signature Miro Chueh/ Technical director Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 5 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 1. Summary of Test Procedure and Test Results Test Item Normative References Test Result Conducted Emission EN55022:2010/AC:2011 PASS Radiated Emission EN55022:2010/AC:2011 PASS Harmonics EN 61000-3-2 : 2006+A2: 2009 PASS Voltage Fluctuations EN 61000-3-3: 2008 PASS IEC 61000-4-2 : 2008 PASS IEC 61000-4-3 : 2006+A1:2007+A2:2010 PASS IEC 61000-4-4 : 2012 PASS IEC 61000-4-5 : 2005 PASS IEC 61000-4-6 : 2008 PASS IEC 61000-4-8 : 2009 N/A IEC 61000-4-11 : 2004 PASS Electrostatic Discharge Immunity Test (ESD) Radio Frequency electromagnetic field immunity test (RS) Electrical Fast Transient/ Burst Immunity Test (EFT) Surge Immunity Test Conduction Disturbances induced by Radio-Frequency Fields Power Frequency Magnetic Field Immunity Test Voltage Dips and Voltage Interruptions Immunity Test 2. Immunity Testing Performance Criteria Definition A. Normal performance within limits specified by the manufacture, requestor or purchaser; B. Temporary loss of function or degradation of performance which ceases after the disturbance ceases, and from which the equipment under test recovers its normal performance, without operator intervention; C. Temporary loss of function or degradation of performance, the correction of which requires operation intervention; D. Loss of function or degradation of performance which is not recoverable, owing to damage to hardware or software, or loss of data. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 6 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 3. Test Configuration of Equipment under Test 3.1. Factory Intracom Asia Co., Ltd 4F., No.77, Sec.1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221, Taiwan 3.2. Feature of Equipment under Test Equipment Fast Ethernet PCI Network Card Model No: 509510 3.3. Test Manner a During testing, the interface cables and equipment positions were varied according to Europe Standard. b The complete test system included auxiliary equipment and EUT for EMI test. c And then test. The pre-test modes Conducted Emission Test Mode 1: Normal Link (Power port) Conducted Emission ISN RJ45 10Mbps /100Mbps LINK 10% (Telecom port) Radiated Emission Test Mode 1: Normal Link EMS/H-F: The worse case was selected as the final test mode and record in the report Test Mode 1: Normal Link Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 7 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 3.4. Description of Test System No Device Manufacturer Model No. Description 1 PC DELL Dell Optitle 380 N/A 2 Notebook SONY PCG-71811P R33021 3 LCD Monitor DELL U3011T R43004 4 Printer HP DESKJET 400 N/A 5 HDD N/A USB 3.0 HDD N/A 6 USB Mouse DELL OXN967 R41108 7 USB Mouse DELL MG1090 R41108 8 USB Keyboard DELL SK-8115 T3A002 Use Cable: No. Cable Quantity A RJ45 1 1m Shielded with two core B VGA Cable 1 1.8 Shielded with two core C USB Cable 1 1.8 Shielded D USB Cable 1 0.4 Unshielded E USB Cable 1 1.8 Unshielded F USB Cable 1 1.8 Unshielded G USB Cable 1 1.8 Unshielded Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Description Issued Date : Oct.31, 2014 Page No. : 8 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 3.5. General Information of Test Test Site: Cerpass Technology (Suzhou) Co.,Ltd No.66,Tangzhuang Road, Suzhou Industrial Park, Jiangsu Test Site Location : 215006, China NVLAP LAB Code : 200814-0 FCC Registration Number : 916572, 331395 IC Registration Number : 7290A-1, 7290A-2 T-1945 for Telecommunication Test VCCI Registration Number : C-2919 for Conducted emission test R-2670 for Radiated emission test below 1GHz G-227 for Radiated emission test above 1GHz Conducted Emission Test: from 150kHz to 30 MHz Frequency Range Radiated Emission Test: from 30 MHz to 1,000 MHz Investigated : Radiated Emission Test: from 1GHz to 6GHz The test distance of radiated emission below 1GHz from antenna to EUT is 10 M. Test Distance : The test distance of radiated emission above 1GHz from antenna to EUT is 3 M. LABORATORY ACCREDIATION 3.6. Measurement Uncertainty Test results and Measurement uncertainty without any relationship in the test report. Conducted Emission The measurement uncertainty is evaluated as ± 2.71 dB. Radiated Emission (30MHz -1000MHz) (1G-6GHz) Horizontal The measurement uncertainty is evaluated as ±3.59 dB. Vertical The measurement uncertainty is evaluated as ± 3.89 dB Horizontal The measurement uncertainty is evaluated as ± 2.31 dB. Vertical The measurement uncertainty is evaluated as ± 2.15 dB. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 9 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 4. Test of Conducted Emission 4.1. Test Limit Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz and return leads of the EUT according to the methods defined in European Standard EN 55022 Clause 9. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in section 5.2. The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position producing maximum conducted emissions. Table 1 Class B Line Conducted Emission Limits: Frequency range (MHz) Quasi Peak Average 0.15 to 0.50 66 to 56 56 to 46 0.50 to 5 56 46 5. to 30. 60 50 Limits (dB µ V) Note 1: The lower limits shall apply at the transition frequencies. Note 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50MHz. Table 2 - Limits of conducted common mode (asymmetric mode) disturbance at telecommunication ports in the frequency range 0.15 MHz to 30 MHz for class B equipment. Frequency range (MHz) Voltage limits Current limits dB(μV) dB(μA) Quasi-peak Average Quasi-peak Average 0.15 to 0.5 84 to 74 74 to 64 40 to 30 30 to 20 0.5 to 30 74 64 30 20 Note 1: The limits decrease linearly with the logarithm of the frequency in the range 0.15 to 0.5 MHz. Note 2: The current and voltage disturbance limits are derived for use with an impedance stabilization network (ISN) which presents a common mode (asymmetric mode) impedance of 150Ω to the telecommunication under test (conversion factor is 20 log10 150/1 = 44dB). Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 10 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 4.2. Test Procedures a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from the conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded conducting surface. b. Connect EUT to the power mains through a line impedance stabilization network (LISN). c. All the support units are connecting to the other LISN. d. The LISN provides 50 ohm coupling impedance for the measuring instrument. e. The CISPR states that a 50 ohm, 50 micro-Henry LISN should be used. f. Both sides of AC line were checked for maximum conducted interference. g. The frequency range from 150 kHz to 30 MHz was searched h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 4.3. Typical Test Setup 10cm EUT 80cm 80cm AE 80cm 40cm LISN ISN LISN 40cm Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 11 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 4.4. Measurement equipment 100565 Calibration Date 2014.03.24 2015.03.23 ESH2-Z5 100182 2014.09.11 2015.09.10 R&S ENV216 100325 2013.12.04 2014.12.03 ISN FCC FCC-TLISN-T2-02 20379 2014.03.24 2015.03.23 ISN FCC FCC-TLISN-T4-02 20380 2014.03.24 2015.03.23 ISN FCC FCC-TLISN-T8-02 20381 2014.03.24 2015.03.23 ISN TESEQ ISN ST08 30175 2014.03.24 2015.03.23 Current Probe R&S EZ-17 100303 2014.04.04 2015.04.03 Passive Voltage Probe R&S ESH2-Z3 100026 2014.03.24 2015.03.23 Pulse Limiter R&S ESH3-Z2 100529 2014.03.24 2015.03.23 Temperature/ Humidity Meter Zhicheng ZC1-11 CEP-TH-004 2014.03.31 2015.03.30 Instrument/Ancillary Manufacturer Model No. Serial No. Test Receiver R&S ESCI AMN R&S Two-Line V-Network Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Valid Date. Issued Date : Oct.31, 2014 Page No. : 12 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 4.5. Test Data and Result Test Mode : Mode 1: Normal Link AC Power : AC 230V/50Hz Phase : LINE Temperature : 22°C Humidity : 50% Pressure(mbar) : 1002 Date: 2014/10/23 No. Frequency (MHz) Factor (dB) Reading (dBuV) Level (dBuV) Limit (dBuV) Margin (dB) Detector 1 0.1500 9.70 34.97 44.67 65.99 -21.32 QP 2 0.1500 9.70 32.59 42.29 56.00 -13.71 AVG 3 0.2100 9.69 39.67 49.36 63.20 -13.84 QP 4 0.2100 9.69 39.07 48.76 54.28 -5.52 AVG 5 0.3500 9.67 31.75 41.42 58.96 -17.54 QP 6 0.3500 9.67 29.86 39.53 50.28 -10.75 AVG 7 0.4220 9.67 27.83 37.50 57.41 -19.91 QP 8 0.4220 9.67 25.19 34.86 48.23 -13.37 AVG 9 1.3420 9.66 23.75 33.41 56.00 -22.59 QP 10 1.3420 9.66 18.47 28.13 46.00 -17.87 AVG 11 15.8660 10.02 30.06 40.08 60.00 -19.92 QP 12 15.8660 10.02 28.68 38.70 50.00 -11.30 AVG Note: Measurement Level = Reading Level + Correct Factor+ Attenuator Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 13 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Test Mode : Mode 1: Normal Link AC Power : AC 230V/50Hz Phase : NEUTRAL Temperature : 22°C Humidity : 50% Pressure(mbar) : 1002 Date: 2014/10/23 No. Frequency (MHz) Factor (dB) Reading (dBuV) Level (dBuV) Limit (dBuV) Margin (dB) Detector 1 0.1500 9.70 34.81 44.51 65.99 -21.48 QP 2 0.1500 9.70 32.40 42.10 56.00 -13.90 AVG 3 0.2100 9.69 39.68 49.37 63.20 -13.83 QP 4 0.2100 9.69 39.09 48.78 54.28 -5.50 AVG 5 0.3500 9.67 31.77 41.44 58.96 -17.52 QP 6 0.3500 9.67 29.94 39.61 50.28 -10.67 AVG 7 1.3099 9.66 22.47 32.13 56.00 -23.87 QP 8 1.3099 9.66 17.25 26.91 46.00 -19.09 AVG 9 13.9500 9.95 30.63 40.58 60.00 -19.42 QP 10 13.9500 9.95 30.34 40.29 50.00 -9.71 AVG 11 14.8460 9.98 29.71 39.69 60.00 -20.31 QP 12 14.8460 9.98 29.03 39.01 50.00 -10.99 AVG Note: Measurement Level = Reading Level + Correct Factor+ Attenuator Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 14 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Test Mode : ISN RJ45 10Mbps LINK 10% AC Power : AC 230V/50Hz Phase : 10M Temperature : 22°C Humidity : 50% Pressure(mbar) : 1002 Date: 2014/10/31 No. Frequency (MHz) Factor (dB) Reading (dBuV) Level (dBuV) Limit (dBuV) Margin (dB) Detector 1 1.0820 19.61 29.24 48.85 74.00 -25.15 QP 2 1.0820 19.61 22.91 42.52 64.00 -21.48 AVG 3 3.6380 19.64 26.17 45.81 74.00 -28.19 QP 4 3.6380 19.64 16.70 36.34 64.00 -27.66 AVG 5 5.4660 19.66 3.82 23.48 74.00 -50.52 QP 6 5.4660 19.66 -1.03 18.63 64.00 -45.37 AVG 7 9.9060 19.78 21.51 41.29 74.00 -32.71 QP 8 9.9060 19.78 14.30 34.08 64.00 -29.92 AVG 9 12.5180 19.75 15.74 35.49 74.00 -38.51 QP 10 12.5180 19.75 9.82 29.57 64.00 -34.43 AVG 11 26.3020 19.84 23.44 43.28 74.00 -30.72 QP 12 26.3020 19.84 17.05 36.89 64.00 -27.11 AVG Note: Measurement Level = Reading Level + Correct Factor+ Attenuator Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 15 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Test Mode : ISN RJ45 100M LINK 10% AC Power : AC 230V/50Hz Phase : 100M Temperature : 22°C Humidity : 50% Pressure(mbar) : 1002 Date: 2014/09/15 No. Frequency (MHz) Factor (dB) Reading (dBuV) Level (dBuV) Limit (dBuV) Margin (dB) Detector 1 7.9260 19.69 35.89 55.58 74.00 -18.42 QP 2 7.9260 19.69 32.62 52.31 64.00 -11.69 AVG 3 11.8940 19.76 35.76 55.52 74.00 -18.48 QP 4 11.8940 19.76 33.34 53.10 64.00 -10.90 AVG 5 16.2300 19.74 35.41 55.15 74.00 -18.85 QP 6 16.2300 19.74 34.38 54.12 64.00 -9.88 AVG 7 18.2500 19.78 36.94 56.72 74.00 -17.28 QP 8 18.2500 19.78 37.12 56.90 64.00 -7.10 AVG 9 23.1340 19.81 37.58 57.39 74.00 -16.61 QP 10 23.1340 19.81 37.78 57.59 64.00 -6.41 AVG 11 26.6180 19.85 36.74 56.59 74.00 -17.41 QP 12 26.6180 19.85 36.45 56.30 64.00 -7.70 AVG Note: Measurement Level = Reading Level + Correct Factor+ Attenuator Test engineer: Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 16 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 4.6. Report No.: DECE1408123 Test Photographs Front View Rear View Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 17 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 ISN 10M&100M Front View Rear View Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 18 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 5. Test of Radiated Emission 5.1. Test Limit Table – Limits for radiated disturbance of class B ITE at a measuring distance of 3 m Frequency range Quasi-peak limits MHz dB(μV/m) 30 to 230 40 230 to 1000 47 NOTE 1 The lower limit shall apply at the transition frequency. NOTE 2 Additional provisions may be required for cases where interference occurs. The EUT shall meet the limits of below Table when measured in accordance with the method described in European Standard EN 55022 Clause 10 and the conditional testing procedure described below. Table – Limits for radiated disturbance of class B ITE at a measuring distance of 3 m Frequency range Average limit Peak limits GHz dB(μV/m) dB(μV/m) 1 to 3 50 70 3 to 6 54 74 NOTE The lower limit applies at the transition frequency. • Conditional testing procedure: The highest internal source of an EUT is defined as the highest frequency generated or used within the EUT or on which the EUT operates or tunes. If the highest frequency of the internal sources of the EUT is less than 108 MHz, the measurement shall only be made up to 1 GHz. If the highest frequency of the internal sources of the EUT is between 108 MHz and 500 MHz, the measurement shall only be made up to 2 GHz. If the highest frequency of the internal sources of the EUT is between 500 MHz and 1 GHz, the measurement shall only be made up to 5 GHz. If the highest frequency of the internal sources of the EUT is above 1 GHz, the measurement shall be made up to 5 times the highest frequency or 6 GHz, whichever is less. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 19 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 5.2. Test Procedures a. The EUT was placed on a relatable table top 0.8 meter above ground. b. The EUT was set 3/10 meters from the interference receiving antenna which was mounted on the top of a variable height antenna tower. c. The table was rotated 360 degrees to determine the position of the highest radiation. d. The antenna is a half wave dipole and its height is varied between one meter and four meters above ground to find the maximum value of the field strength both horizontal polarization and vertical polarization of the antenna are set to make the measurement. e. For each suspected emission the EUT was arranged to its worst case and then tune the antenna tower (from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the maximum reading. f. Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum Hold Mode. g. If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 dB margin will be repeated one by one using the quasi-peak method and reported. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 20 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 5.3. Typical test Setup Below 1GHz Test Setup Above 1GHz Test Setup Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 21 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 5.4. Measurement equipment 100853 Calibration Date 2014.03.01 2015.02.28 3113A05915 2014.03.01 2015.02.28 1579008 2013.11.27 2014.11.26 Instrument/Ancillary Manufacturer Model No. Serial No. EMI Test Receiver R&S ESCI Preamplifier HP 8447F Preamplifier FIELD Ultra Broadband Antenna Broad-Band Horn Antenna Spectrum Analyzer Temperature/ Humidity Meter AFS44-00101800 -25-10P-44 Valid Date. SCHAFFNER CBL6112D 22241 2014.03.04 2015. 03.03 Sunol DRH-118 A072913 2014.10.16 2014.10.15 Agilent E4407B MY45118947 2014.07.18 2015.07.17 VICHY CTH-608 Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 N/A 2014.03.04 2015.03.03 Issued Date : Oct.31, 2014 Page No. : 22 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 5.5. Test Result and Data (30MHz ~ 1000MHz) Test Mode : Test Mode 1: Normal Link AC Power : AC 230V/50Hz Ant. Polarization: Horizontal Temp : 23℃ Humidity : 52% Pressure(mbar) : 1002 Date : 2014/10/23 No. Frequency (MHz) Factor (dB/m) Reading (dBuV) Level (dBuV/m) Limit (dBuV/m) Margin (dB) Det. Height (cm) Azimuth (deg) 1 232.7300 -9.44 47.29 37.85 47.00 -9.15 peak 100 22 2 250.1900 -8.37 48.37 40.00 47.00 -7.00 peak 100 75 3 364.6500 -4.54 48.50 43.96 47.00 -3.04 peak 200 121 4 433.5200 -4.46 43.69 39.23 47.00 -7.77 peak 200 245 5 500.4500 -2.20 44.66 42.46 47.00 -4.54 peak 200 312 6 760.4100 1.78 39.00 40.78 47.00 -6.22 peak 200 88 Note: Measurement Level = Reading Level + Correct Factor Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 23 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Test Mode : Test Mode 1: Normal Link AC Power : AC 230V/50Hz Ant. Polarization: Vertical Temp : 23℃ Humidity : 52% Pressure(mbar) : 1002 Date : 2014/10/23 No. Frequency (MHz) Factor (dB/m) Reading (dBuV) Level (dBuV/m) Limit (dBuV/m) Margin (dB) Det. Height (cm) Azimuth (deg) 1 44.5500 -12.12 47.43 35.31 40.00 -4.69 peak 100 37 2 165.8000 -12.26 46.28 34.02 40.00 -5.98 peak 100 58 3 366.5900 -4.60 48.50 43.90 47.00 -3.10 peak 100 99 4 433.5200 -4.46 44.18 39.72 47.00 -7.28 peak 200 159 5 500.4500 -2.20 43.32 41.12 47.00 -5.88 peak 200 246 6 760.4100 1.78 37.58 39.36 47.00 -7.64 peak 100 6 Note: Measurement Level = Reading Level + Correct Factor Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 24 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 5.6. Test Result and Data (1000MHz ~ 6000MHz) No. Test Mode : Test Mode 1: Normal Link AC Power : AC 230V/50Hz Ant. Polarization: Horizontal Temp : 23℃ Humidity : 52% Pressure(mbar) : 1002 Date : 2014/10/30 Frequency Factor Reading Level Limit Margin (MHz) (dB/m) (dBuV) (dBuV/m) (dBuV/m) (dB) 1 1187.500 -10.46 53.34 42.88 70.00 -27.12 2 1312.500 -9.32 51.49 42.17 70.00 3 1425.000 -8.29 50.35 42.06 4 1500.000 -7.61 49.84 5 2487.500 -2.63 6 3200.000 1.82 Det. Height Azimuth (cm) (deg) peak 100 116 -27.83 peak 100 128 70.00 -27.94 peak 100 356 42.23 70.00 -27.77 peak 100 301 44.03 41.40 70.00 -28.60 peak 100 283 42.25 44.07 74.00 -29.93 peak 100 140 Note: Measurement Level = Reading Level + Correct Factor Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 25 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Test Mode : Test Mode 1: Normal Link AC Power : AC 230V/50Hz Ant. Polarization: Vertical Temp : 23℃ Humidity : 52% Pressure(mbar) : 1002 Date : 2014/10/30 No. Frequency Factor Reading Level Limit Margin (MHz) (dB/m) (dBuV) (dBuV/m) (dBuV/m) (dB) 1 1075.000 -11.49 58.12 46.63 70.00 -23.37 2 1275.000 -9.66 57.78 48.12 70.00 3 1375.000 -8.75 56.36 47.61 4 1437.500 -8.18 57.25 5 1475.000 -7.84 6 1475.000 7 1937.500 Det. Height Azimuth (cm) (deg) peak 100 101 -21.88 peak 100 230 70.00 -22.39 peak 100 194 49.07 70.00 -20.93 peak 100 62 58.07 50.23 70.00 -19.77 peak 100 155 -7.84 38.62 30.78 50.00 -19.22 AVG 100 155 -5.09 52.26 47.17 70.00 -22.83 peak 100 32 Note: Measurement Level = Reading Level + Correct Factor Test engineer: Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 26 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 5.7. Test Photographs (30MHz ~ 1000MHz) Front View Rear View Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 27 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 5.8. Test Photographs (1000MHz ~ 6000MHz) Front View Rear View Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 28 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 6. Harmonics Test 6.1. Limits Of Harmonics Current Measurement Limits for Class D equipment Limits for Class A equipment Harmonics Max. Permissible Harmonics Max. Permissible Max. Permissible Order harmonics Order harmonics current per harmonics current n current n watt mA/W A A Odd harmonics Odd Harmonics only 3 2.30 3 3.4 2.30 5 1.14 5 1.9 1.14 7 0.77 7 1.0 0.77 9 0.40 9 0.5 0.40 11 0.33 11 0.35 0.33 13 0.21 13 0.30 0.21 15<=n<=39 0.15¯15/n 15<=n<=39 3.85/n 0.15 x15/n Even harmonics 2 1.08 4 0.43 6 0.30 8<=n<=40 0.23¯8/n NOTE: i. Class A and Class D are classified according to item section 5 of EN 61000-3-2. ii. According go section 7 of EN 61000-3-2, the above limits for all equipment except for lighting equipment are for all applications having a rated power > 75 W and no limits apply for equipment with a rated power up to and including 75 W. 6.2. Measurement equipment NSG 1007-3 Calibration Date 1330A03972 2014.10.15 2015.10.14 TESEQ CCN 1000-1 1330A03972 2014.10.15 2015.10.14 mingle ETH529 Instrument/Ancillary Manufacturer Model No. Power Source Harmonic & Flicker Tester Temperature/ Humidity Meter TESEQ Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Serial No. N/A 2014.11.06 Valid Date. 2015.11.05 Issued Date : Oct.31, 2014 Page No. : 29 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 6.3. Test Result and Data Basic Standard : EN 61000-3-2 Final Test Result : PASS Test Mode : Mode 1: Normal Link Temperature : 22℃ Humidity : 50 % Atmospheric Pressure : 100 kPa Test Data : Oct.25,2014 Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 30 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Harmonics – Class-D per Ed. 3.2 (2009)(Run time) incl. inter-harmonics 3 300 2 200 1 100 0 0 -1 -100 -2 -200 -3 -300 Current RMS(Amps) Harmonics and Class D limit line Voltage (Volts) Current (Amps) EUT: Fast Ethernet PCI Network Card Tested by: Wayne Test category: Class-D per Ed. 3.2 (2009) (European limits) Test Margin: 100 Test date: 2014-10-25 Start time: 16:56:57 End time: 17:12:18 Test duration (min): 15 Data file name: H-010605.cts_data Comment: 509510 Customer: Intracom Asia Co., Ltd Test Result: Pass Source qualification: Normal Current & voltage waveforms European Limits 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 4 8 12 16 20 24 Harmonic # 28 32 36 40 Test result: Pass Worst harmonic was #3 with 25.99% of the limit. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 31 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 Current Test Result Summary (Run time) EUT: Fast Ethernet PCI Network Card Tested by: Wayne Test category: Class-D per Ed. 3.2 (2009) (European limits) Test Margin: 100 Test date: 2014-10-25 Start time: 16:56:57 End time: 17:12:18 Test duration (min): 15 Data file name: H-010605.cts_data Comment: 509510 Customer: Intracom Asia Co., Ltd Test Result: Pass Source qualification: Normal THC(A): 0.18 I-THD(%): 20.27 POHC(A): 0.000 POHC Limit(A): 0.089 Highest parameter values during test: V_RMS (Volts): 230.50 Frequency(Hz): 50.00 I_Peak (Amps): 1.844 I_RMS (Amps): 0.932 I_Fund (Amps): 0.913 Crest Factor: 1.985 Power (Watts): 206.8 Power Factor: 0.963 Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 0.000 0.183 0.000 0.019 0.000 0.013 0.000 0.007 0.000 0.004 0.000 0.004 0.000 0.004 0.000 0.004 0.000 0.004 0.000 0.004 0.000 0.003 0.000 0.003 0.000 0.003 0.000 0.003 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.703 26.0 0.185 1.044 17.71 Pass 0.393 4.8 0.019 0.582 3.33 Pass 0.207 6.3 0.013 0.308 4.36 Pass 0.103 7.2 0.008 0.155 4.98 Pass 0.072 5.9 0.000 0.000 0.00 Pass 0.062 5.8 0.000 0.000 0.00 Pass 0.054 6.8 0.000 0.000 0.00 Pass 0.048 8.9 0.000 0.000 0.00 Pass 0.042 8.8 0.000 0.000 0.00 Pass 0.038 9.7 0.000 0.000 0.00 Pass 0.035 10.0 0.000 0.000 0.00 Pass 0.032 10.6 0.000 0.000 0.00 Pass 0.030 9.3 0.000 0.000 0.00 Pass 0.027 9.4 0.000 0.000 0.00 Pass 0.026 9.3 0.000 0.000 0.00 Pass 0.024 9.8 0.000 0.000 0.00 Pass 0.023 8.5 0.000 0.000 0.00 Pass 0.022 10.2 0.000 0.000 0.00 Pass 0.020 11.4 0.000 0.000 0.00 Pass Note: Dynamic limits were applied for this test. window as the maximum harmonics/limit ratio. The highest harmonics values in the above table may not occur at the same Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 32 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 Voltage Source Verification Data (Run time) EUT: Fast Ethernet PCI Network Card Tested by: Wayne Test category: Class-D per Ed. 3.2 (2009) (European limits) Test Margin: 100 Test date: 2014-10-25 Start time: 16:56:57 End time:17:12:18 Test duration (min): 15 Data file name: H-010605.cts_data Comment: 509510 Customer: Intracom Asia Co., Ltd Test Result: Pass Source qualification: Normal Highest parameter values during test: Voltage (Vrms): 230.50 Frequency(Hz): 50.00 I_Peak (Amps): 1.844 I_RMS (Amps): 0.932 I_Fund (Amps): 0.913 Crest Factor: 1.985 Power (Watts): 206.8 Power Factor: 0.963 Harm# 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Harmonics V-rms Limit V-rms % of Limit Status 0.078 0.464 0.051 0.021 0.023 0.047 0.018 0.069 0.018 0.034 0.014 0.018 0.004 0.015 0.011 0.010 0.014 0.011 0.013 0.006 0.006 0.008 0.004 0.006 0.004 0.008 0.004 0.007 0.003 0.004 0.002 0.006 0.003 0.005 0.002 0.005 0.002 0.005 0.006 0.461 2.074 0.461 0.922 0.461 0.691 0.461 0.461 0.461 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 16.92 22.37 11.13 2.23 4.92 6.79 3.89 14.91 3.85 14.58 5.91 7.86 1.91 6.54 4.92 4.49 5.99 4.56 5.47 2.53 2.68 3.49 1.84 2.57 1.74 3.60 1.59 3.25 1.42 1.92 1.06 2.51 1.35 1.97 0.92 2.18 1.02 2.09 2.68 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 33 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 6.4. Report No.: DECE1408123 Test Photographs Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 34 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 7. Voltage Fluctuations Test 7.1. Test Procedure The equipment shall be tested under the conditions of Clause 5. The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance. The stability and tolerance of the reference impedance shall be adequate to ensure that the overall accuracy of ±8% is achieved during the whole assessment procedure. 7.2. Measurement equipment NSG 1007-3 Calibration Date 1330A03972 2014.10.15 2015.10.14 TESEQ CCN 1000-1 1330A03972 2014.10.15 2015.10.14 mingle ETH529 Instrument/Ancillary Manufacturer Model No. Power Source Harmonic & Flicker Tester Temperature/ Humidity Meter TESEQ Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Serial No. N/A 2014.11.06 Valid Date. 2015.11.05 Issued Date : Oct.31, 2014 Page No. : 35 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 7.3. Report No.: DECE1408123 Test Result and Data Basic Standard : EN 61000-3-3 Final Test Result : PASS Test Mode : Mode 1: Normal Link Temperature : 22℃ Humidity : 50% Atmospheric Pressure : 100 kPa Test Data : Oct.25,2014 Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 36 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Flicker Test Summary per EN/IEC61000-3-3 Report No.: DECE1408123 (Run time) EUT: Fast Ethernet PCI Network Card Tested by: Wayne Test category: All parameters (European limits) Test Margin: 100 Test date: 2014-10-25 Start time: 17:20:12 End time: 17:30:33 Test duration (min): 10 Data file name: F-010606.cts_data Comment: 509510 Customer: Intracom Asia Co., Ltd Test Result: Pass Status: Test Completed Psti and limit line European Limits 1.00 Pst 0.75 0.50 0.25 17:30:32 Plt and limit line Plt 0.50 0.25 0.00 17:30:32 Parameter values recorded during the test: Vrms at the end of test (Volt): 230.35 Highest dt (%): 0.00 Time(mS) > dt: 0.0 Highest dc (%): 0.00 Highest dmax (%): 0.00 Highest Pst (10 min. period): 0.064 Highest Plt (2 hr. period): 0.028 Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Test limit (%): Test limit (mS): Test limit (%): Test limit (%): Test limit: Test limit: 3.30 500.0 3.30 4.00 1.000 0.650 Pass Pass Pass Pass Pass Pass Issued Date : Oct.31, 2014 Page No. : 37 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 7.4. Report No.: DECE1408123 Test Photographs Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 38 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 8. Electrostatic Discharge Immunity Test 8.1. Test Procedure a. In the case of air discharge testing the climatic conditions shall be within the following ranges: - ambient temperature: 15℃ to 35℃; - relative humidity : 30% to 60%; - atmospheric pressure : 86 KPa (860 hPa) to 106 KPa (1060 hPa). b. Test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. c. The test voltage shall be increased from the minimum to the selected test severity level, in order to determine any threshold of failure. The final severity level should not exceed the product specification value in order to avoid damage to the equipment. d. The test shall be performed with both air discharge and contact discharge. On reselected points at least 10 single discharges (in the most sensitive polarity) shall be applied on air discharge. On reselected points at least 25 single discharges (in the most sensitive polarity) shall be applied on contact discharge. e. For the time interval between successive single discharges an initial value of one second is recommended. Longer intervals may be necessary to determine whether a system failure has occurred. f. In the case of contact discharges, the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. g. In the case of painted surface covering a conducting substrate, the following procedure shall be adopted : If the coating is not declared to be an insulating coating by the equipment manufacturer, then the pointed tip of the generator shall penetrate the coating so as to make contact with the conducting substrate. Coating declared as insulating by the manufacturer shall only be submitted to the air discharge. The contact discharge test shall not be applied to such surfaces. h. In the case of air discharges, the round discharge tip of the discharge electrode shall be approached as fast as possible (without causing mechanical damage) to touch the EUT . After each discharge, the ESD generator (discharge electrode) shall be removed from the EUT. The generator is then retriggered for a new single discharge. This procedure shall be repeated until the discharges are completed. In the case of an air discharge test, the discharge switch, which is used for contact discharge, shall be closed. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 39 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 8.2. Test Setup for Tests Performed in Laboratory The test setup consists of the test generator, EUT and auxiliary instrumentation necessary to perform DIRECT and INDIRECT application of discharges to the EUT as applicable, in the follow manner : a. Contact Discharge to the conductive surfaces and to coupling plane; b. Air Discharge at insulating surfaces. The preferred test method is that of type tests performed in laboratories and the only accepted method of demonstrating conformance with this standard. The EUT was arranged as closely as possible to arrangement in final installed conditions. A ground reference plane was provided on the floor of the test site. It was a metallic sheet (copper or aluminum) of 0.25 mm, minimum thickness; other metallic may be used but they shall have at least 0.65 mm thickness. In the Exclusive Certification Corp., we provided 1 mm thickness stainless steel ground reference plane. The minimum size of the ground reference plane is 2.5 m x 2.5 m, the exact size depending on the dimensions of the EUT. It was connected to the protective grounding system. The EUT was arranged and connected according to its functional requirements. A distance of 1m minimum was provided between the EUT and the wall of the lab. and any other metallic structure. In cases where this length exceeds the length necessary to apply the discharges to the selected points, the excess length shall, where possible, be placed non-inductively off the ground reference plane and shall not come closer than 0.2m to other conductive parts in the test setup. Where the EUT is installed on a metal table, the table was connected to the reference plane via a cable with a 470k ohm resister located at each end, to prevent a build-up of charge. The test setup was consist a wooden table, 0.8m high, standing on the ground reference plane. A HCP, 1.6 m x 0.8 m, was placed on the table. The EUT and cables was isolated from the HCP by an insulating support 0.5 mm thick. The VCP size, 0.5 m x 0.5 m. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 40 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 8.3. Test Severity Levels Contact Discharge Level Air Discharge Test Voltage (kV) of Level Test Voltage (kV) of Contact discharge Air Discharge 1 ±2 1 ±2 2 ±4 2 ±4 3 ±6 3 ±8 4 ±8 4 ±15 X Specified X Specified Remark: “X” is an open level. 8.4. Measurement equipment 575 Calibration Date 2014.03.03 2015.03. 02 N/A 2014.03.04 2015.03.03 Instrument/Ancillary Manufacturer Model No. Serial No. ESD Simulator TESEQ NSG437 VICHY CTH-608 Temperature/ Humidity Meter Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Valid Date. Issued Date : Oct.31, 2014 Page No. : 41 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 8.5. Test Result and Data Basic Standard : IEC 61000-4-2 Final Test Result : PASS Pass performance criteria : B Temperature ±2 / ±4 / ±8 kV for air discharge, ±2 / ±4 kV for contact discharge : 20°C Relative Humidity : 50 % Atmospheric Pressure : 100 kPa Test Date : Oct.27,2014 Test Voltage : Mode 1: Normal Link Contact Discharge 25 Voltage Point\Polarity Air Discharge times / each 6 kV - 10 2 kV + - + 4 kV - + 2 kV + - 4 kV + - 8 kV + - 10 kV + - HCP A A A A --- --- --- --- --- --- --- --- --- --- --- --- VCP A A A A --- --- --- --- --- --- --- --- --- --- --- --- Screw A A A A --- --- --- --- --- --- --- --- --- --- --- --- Case A A A A --- --- --- --- --- --- --- --- --- --- --- --- NIC Port --- --- --- --- --- --- --- --- A A A A A A --- --- + 8 kV - times / each Test engineer: Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 42 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 8.6. Report No.: DECE1408123 Test Photographs Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 43 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 9. Radio Frequency electromagnetic field immunity test 9.1. Test Procedure a. The equipment to be tested is placed in the center of the enclosure on a wooden table. The equipment is then connected to power and signal leads according to pertinent installation instructions. b. The antenna which is enabling the complete frequency range of 80-1000 MHz is placed 3m away from the equipment. The required field strength is determined by placing the field strength meter(s) on top of or directly alongside the equipment under test and monitoring the field strength meter via a remote field strength indicator outside the enclosure while adjusting the continuous-wave to the applicable antennae. c. The test is normally performed with the antenna facing the most sensitive side of the EUT. The polarization of the field generated by the bucolical antenna necessitates testing each position twice, once with the antenna positioned vertically and again with the antenna positioned horizontally. The circular polarization of the field from the log-spiral antenna makes a change of position of the antenna unnecessary. d. At each of the above conditions, the frequency range is swept 80-1000 MHz, pausing to adjust the R.F. signal level or to switch oscillators and antenna. The rate of sweep is in the order of 1.5*10-3 decades/s. The sensitive frequencies or frequencies of dominant interest may be discretely analyzed. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 44 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 9.2. Test Severity Levels Frequency Band : 80-1000 MHz Level Test field strength (V/m) 1 1 2 3 3 10 X Specified Remark: “X” is an open class. 9.3. Measurement equipment 103287 Calibration Date 2014.03.24 2015.03.23 NR P-Z91 100383 2014.03.24 2015.03.23 R&S NRP-Z91 100384 2014.03.24 2015.03.23 Power Meter R&S NRP 101206 2014.03.24 2015.03.23 Power Amplifer BONN 076659 2014.03.24 2015.03.23 HI-6105 137445 2014.09.03 2015.09.02 Instrument/Ancillary Manufacturer Model No. Serial No. Signal Generator R&S SML03 Power Sensor R&S Power Sensor Istropic Electric Field EST.LINDGRE BLWA0830-16 0/100/40D Valid Date. Probe N EMS Antenna R&S HL046E 100028 N/A N/A feiyan N/A 101 2014.03.31 2015.03.30 Temperature/ Humidity Meter Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 45 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 9.4. Test Result and Data Basic Standard : IEC 61000-4-3 Final Test Result : PASS Pass performance criteria : A Frequency Range : 80~1000 MHz Temperature : 22°C Relative Humidity : 52% Atmospheric Pressure : 100 kPa Test Date : Oct.31,2014 Mode 1: Normal Link Modulation : AM 80% , 1KHz sine wave , Dwell time: 3 S Frequency Step Size : 1 % of preceding frequency value Frequency (MHz) Antenna Polarization face Field strength (V/m) Result 80~1000 Horizontal &Vertical Front 3 V/m A 80~1000 Horizontal &Vertical Rear 3 V/m A 80~1000 Horizontal &Vertical Left 3 V/m A 80~1000 Horizontal &Vertical Right 3 V/m A Test engineer: Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 46 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 9.5. Report No.: DECE1408123 Test Photographs Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 47 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 10. Electrical Fast Transient/ Burst Immunity Test 10.1. Test Procedure a. In order to minimize the effect of environmental parameters on test results, the climatic conditions when test is carrying out shall comply with the following requirements: ambient temperature: 15℃ to 35℃; relative humidity : 45% to 75%; Atmospheric pressure: 86 Kpa (860 hPa) to 106 Kpa (1060 hPa). b. In order to minimize the effect of environmental parameters on test results, the electromagnetic environment of the laboratory shall not influence the test results. c. The variety and diversity of equipment and systems to be tested make it difficult to establish general criteria for the evaluation of the effects of fast transients/bursts on equipment and systems. d. Test on Power Line: The EFT/B-generator was located on the GRP.. The length from the EFT/B-generator to the EUT is not exceeding 1 m. The EFT/B-generator provides the ability to apply the test voltage in a non-symmetrical condition to the power supply input terminals of the EUT. e. Test on Communication Lines The coupling clamp is composed of a clamp unit for housing the cable (length more than 3 m), and was placed on the GRP. The coupling clamp provides the ability of coupling the fast transient/bursts to the cable under test. f. The test results may be classified on the basic of the operating conditions and the functional specification of the equipment under test, according to the following performance criteria : Normal performance within the specification limits. Temporary degradation or loss of function or performance which is self-recoverable. Temporary degradation or loss of function or performance which requires operator intervention or system reset. Degradation or loss of function which is not recoverable due to damage of equipment (components). Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 48 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 10.2. Test Severity Levels The following test severity levels are recommended for the fast transient/burst test : Open circuit output test voltage ± 10% Level On Power Supply On I/O signal, data and control line 1 0.5 kV 0.25 kV 2 1.0 kV 0.50 kV 3 2.0 kV 1.00 kV 4 4.0 kV 2.00 kV X Specified Specified Remark : “ X ” is an open level. The level is subject to negotiation between the user and the manufacturer or is specified by the manufacturer. 10.3. Measurement equipment 901 Calibration Date 2014.03.24 2015.03.23 EMCPARTNER CDN2000-06-32 121 2014.03.24 2015.03.23 EMCPARTNER CN-EFT1000 547 2014.03.24 2015.03.23 Zhicheng ZC1-11 CEP-TH-005 2014.03.31 2015.03.30 Instrument/Ancillary Manufacturer Model No. Serial No. TRANSIENT EMCPARTNER TRA2000IN6 CDN Coupling clamp Temperature/ Humidity Meter Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Valid Date. Issued Date : Oct.31, 2014 Page No. : 49 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 10.4. Test Result and Data Basic Standard : IEC 61000-4-4 Final Test Result : PASS Pass performance criteria : B Test Voltage : On Power Supply -- ±1.0 kV On I/O signal, data and control line -- ±0.5 kV Temperature : 21°C Relative Humidity : 51 % Atmospheric Pressure : 100 kPa Test Date : Oct.27,2014 Mode 1: Normal Link Pulse : 5/50 ns Repetition Rate: 5 kHz Burst : 15m/300ms Test time : 1 min/each condition Voltage/ Mode/ Polarity/ Result/ Phase Power Line Signal Line 0.5 kV 1.0 kV + - + - L --- --- A A N --- --- A A L-N --- --- A A PE --- --- A A L-PE --- --- A A N-PE --- --- A A L-N-PE --- --- A A RJ 45 A A --- --- Test engineer: Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 50 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 10.5. Report No.: DECE1408123 Test Photographs LAN Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 51 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 11. Surge Immunity Test 11.1. Test Procedure a. Climatic conditions The climatic conditions shall comply with the following requirements : ambient temperature : 15 ℃ to 35 ℃ relative humidity : 10 % to 75 % atmospheric pressure : 86 kPa to 106 kPa ( 860 hPa to 1060 hPa ) b. Electromagnetic conditions the electromagnetic environment of the laboratory shall not influence the test results. c. The test shall be performed according the test plan that shall specify the test set-up with generator and other equipment utilized; test level ( voltage/current ); generator source impedance; internal or external generator trigger; number of tests : at least five positive and five negative at the selected points; repetition rate : maximum 1/min. inputs and outputs to be tested; representative operating conditions of the EUT; sequence of application of the surge to the circuit; phase angle in the case of AC. power supply; actual installation conditions, for example : AC : neutral earthed, DC : ( + ) or ( - ) earthed to simulated the actual earthing conditions. d. If not otherwise specified the surges have to be applied synchronized to the voltage phase at the zero-crossing and the peak value of the AC. voltage wave ( positive and negative ). e. The surges have to be applied line to line and line(s) and earth. When testing line to earth, the test voltage has to be applied successively between each of the lines and earth, if there is no other specification. f. The test procedure shall also consider the non-linear current-voltage characteristics of the equipment under test. Therefore the test voltage has to be increased by steps up to the test level specified in the product standard or test plan. g. All lower levels including the selected test level shall be satisfied. For testing the secondary protection, the output voltage of the generator shall be increased up to the worst-case voltage breakdown level ( let-through level ) of the primary protection. h. If the actual operating signal sources are not available, that may be simulated. Under no circumstances may the test level exceed the product specification. The test shall be carried out according to a test plan. i. To find all critical points of the duty cycle of the equipment, a sufficient number of positive and negative test pulses shall be applied. For acceptance test previously unstressed equipment shall be used to the protection devices shall be replaced. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 52 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 11.2. Test Severity Level Level Open-circuit test voltage, ± 10%, kV 1 0.5 2 1.0 3 2.0 4 4.0 X Specified NOTE: “X” is an open class. This level can be specified in the product specification. 11.3. Measurement equipment 901 Calibration Date 2014.03.24 2015.03.23 021 2014.03.24 2015.03.23 121 2014.03.24 2015.03.23 CEP-TH-005 2014.03.31 2015.03.30 Instrument/Ancillary Manufacturer Model No. Serial No. TRANSIENT EMCPARTNER TRA2000IN6 CDN EMCPARTNER CDN-UTP8 CDN EMCPARTNER CDN2000-06-32 Temperature/ Humidity Meter Zhicheng Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 ZC1-11 Valid Date. Issued Date : Oct.31, 2014 Page No. : 53 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 11.4. Test Result and Data Basic Standard : IEC 61000-4-5 Final Test Result : PASS Pass performance criteria : B Test Voltage : Temperature : 21°C Relative Humidity : 51 % Atmospheric Pressure : 100 kPa Test Date : Oct.27,2014 Input AC Power Port -- ±0.5/1.0 kV for Line to Line ±0.5/1.0 /2.0kV for Line to Ground Power Port Mode 1: Normal Link Test Voltage:230V/50Hz Waveform : 1.2/50μs(8/20μs) Repetition rate : 60 sec Time : 20 time/each condition /Phase Voltage / Mode / Polarity / Result 0° 90° 180° 270° + A A A A - A A A A + A A A A - A A A A + A A A A - A A A A 0.5/1.0 kV L-N L-PE 0.5/1.0/2.0kV N-PE Waveform :10/700μs Repetition rate : 60 sec Time : 5 time/each condition Voltage 0.5 kV 1 kV Mode / Polarity / Result + - + - RJ45 A A B B Test engineer: Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 54 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 11.5. Test Photographs LAN Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 55 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 12. Conduction Disturbances induced by Radio-Frequency Fields 12.1. Test Procedure a. The EUT shall be operated within its intended climatic conditions. The temperature and relative humidity should be recorded. b. This test method test can be performed without using a sell shielded enclosure. This is because the disturbance levels applied and the geometry of the setups are not likely to radiated a high amount of energy, especially at the lower frequencies. If under certain circumstances the radiated energy is too high, a shielded enclosure has to be used. c. The test shall be performed with the test generator connected to each of the coupling and decoupling devices in turn while the other non-excited RF-input ports of the coupling devices are terminated by a 50 ohm load resistor. d. The frequency range is swept from 150 KHz to 80 MHz, using the signal levels established during the setting process, and with the disturbance signal 80% amplitude modulated with a 1KHz sign wave, pausing to adjust the RF-signal level or to switch coupling devices as necessary. The rate of sweep shall no exceed 1.5 x 10-3 decades/s. Where the frequency is swept incrementally, the step size shall no exceed 1% of the start and thereafter 1% of the preceding frequency value. e. The dwell time at each frequency shall not be less than the time necessary for the EUT to be exercised, and able to respond. Sensitive frequencies e.g. clock frequency (ies) and harmonics or frequencies of dominant interest shall be analyzed separately. f. An alternative test procedure may be adopted, wherein the frequency range is swept incrementally, with a step size not exceeding 4% of the start ad thereafter 4% of the preceding frequency value. The test level should be at least twice the value of the specified test level. g. In cases of dispute, the test procedure using a step size not exceeding 1% of the start and thereafter 1% of preceding frequency value shall take precedence. h. Attempts should be made to fully exercise the EUT during testing, and to fully interrogate all exercise modes selected for susceptibility. i. The use of special exercising programs is recommended. j. Testing shall be performed according to a Test Plan, which shall be included in the test report. k. It may be necessary to carry out some investigatory testing in order to establish some aspects of the test plan. Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 56 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 12.2. Test Severity Levels Level Voltage Level ( EMF ), 1 1V 2 3V 3 10 V x Specified NOTE - x is an open class. This level can be specified in the product specification. 12.3. Measurement equipment Manufacturer Model No. Serial No. Calibration Date Valid Date. FRANKONIA CIT-10/75 102D1294 2014.03.24 2015.03.23 EM Injection clamp FCC F-203I-23MM 536 2014.03.24 2015.03.23 CDN FRANKONIA CDN-T2 A3010029 2014.03.24 2015.03.23 CDN FRANKONIA CDN-T4 A3015017 2014.03.24 2015.03.23 CDN FRANKONIA CDN-T8 A3022010 2014.03.24 2015.03.23 CDN FRANKONIA CDN-M2 A3002037 2014.03.24 2015.03.23 CDN FRANKONIA CDN-M2+M3 A3011102 2014.03.24 2015.03.23 CDN FCC CDN-M5/32 A3013024 2014.03.24 2015.03.23 6 dB Attenuator FRANKONIA N/A N/A 2014.03.24 2015.03.23 Zhicheng ZC1-11 CEP-TH-005 2014.03.31 2015.03.30 Instrument/Ancillary Conducted immunity test system Temperature/ Humidity Meter Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 57 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 12.4. Test Result and Data Basic Standard : IEC 61000-4-6 Final Test Result : PASS Pass performance criteria : A Coupling mode : Temperature : 21°C Relative Humidity : 51% Atmospheric Pressure : 100 kPa Test Date : Oct.27,2014 CDN-(M2+M3) for AC power ports CDN-T4 for signal ports EM-Clamp for signal ports Test Mode 1: Normal Link Frequency : 0.15~80MHz, Modulation : AM 80%,1KHz sine wave, Dwell time: 2.9s Frequency Step Size : 1 % of preceding frequency value Frequency Test mode Voltage(V) Result 0.15 ~ 100MHz Power(M3) 3 A 0.15 ~ 100MHz RJ45 3 A Test engineer: Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 58 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 12.5. Test Photographs LAN Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 59 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 13. Power Frequency Magnetic Field Immunity Tests 13.1. Test Setup GPR : Ground plane C1 : Power supply circuit A : Safety earth C2 : Signal circuit S : Insulating support L : Communication line EUT : Equipment under test B : To power supply source Lc : Induction coil D : To signal source, simulator E : Earth terminal G : To the test generator 13.2. Test Severity Levels Level Magnetic field strength A/m 1 3 10 30 100 special 1 2 3 4 5 X1) NOTE 1 “X” is an open level. This level can be givenin the product specification. 13.3. Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Calibration Date Valid Date. TRANSIENT EMCPARTNER TRA2000IN6 901 2014.03.09 2015.03.08 H-Filed-Loop EMCPARTNER MF1000-1 144 2014.03.09 2015.03.08 Temperature/ Humidity Meter Zhicheng ZC1-11 CEP-TH-005 2014.03.09 2015.03.08 Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 60 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 13.4. Test Result and Data Not Applicable Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 61 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 14. Voltage Dips and Voltage Interruptions Immunity Test Setup 14.1. Test Conditions 1. Source voltage and frequency : 230V / 50Hz, Single phase. 2. Test of interval : 10 sec. 3. Level and duration : Sequence of 3 dips/interrupts. 4. Voltage rise (and fall) time : 1 ∼ 5 μs. 5. Test severity : Voltage dips and Interrupt reduction (%) Test Duration (period) >95% 250 30% 25 >95% 0.5 14.2. Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Calibration Date Valid Date. TRANSIENT EMCPARTNER TRA2000IN6 901 2014.03.24 2015.03.23 Zhicheng ZC1-11 CEP-TH-005 2014.03.31 2015.03.30 Temperature/ Humidity Meter Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 62 of 67 Report No.: DECE1408123 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 14.3. Test Result and Data Basic Standard : IEC 61000-4-11 Final Test Result : PASS Pass performance Criteria : C for voltage interruption, B for voltage dips Required performance Criteria : C for voltage interruption, B/C for voltage dips Temperature : 21°C Relative Humidity : 51% Atmospheric Pressure : 100 kPa Test Date : Oct.27,2014 Test Mode 1: Normal Link Voltage(UT): AC 230 V 50 Hz Test mod Voltage interruptions Voltage dips Test level UT % Interval(s) : 10s Times : Durations (period / 0 45 ms ) 3 Phase / Result 90 135 180 225 270 315 >95% 250 C C C C C C C C 30% 25 B B B B B B B B >95% 0.5 B B B B B B B B Test engineer: Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 63 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 14.4. Test Photographs Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 64 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD Report No.: DECE1408123 15. Photographs of EUT 1) EUT Photo 2) EUT Photo Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 65 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 3) EUT Photo 4) EUT Photo Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Report No.: DECE1408123 Issued Date : Oct.31, 2014 Page No. : 66 of 67 CERPASS TECHNOLOGY (SUZHOU)CO.,LTD 5) Report No.: DECE1408123 EUT Photo Cerpass Technology (Suzhou) Co., Ltd TEL: +86-512-6917-5888 FAX: +86-512-6917-5666 Issued Date : Oct.31, 2014 Page No. : 67 of 67
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2014:11:03 18:27:12+08:00 Create Date : 2014:11:03 18:22:41+08:00 Metadata Date : 2014:11:03 18:27:12+08:00 Format : application/pdf Title : Microsoft Word - 1408123-509510-CE REPORT.doc Creator : karent Document ID : uuid:72c23327-d29c-4343-b114-1dba98b0f8ca Instance ID : uuid:4f61b542-f376-4ce4-8948-e979575ee33f Page Count : 67 Author : karentEXIF Metadata provided by EXIF.tools