1408123 509510 CE REPORT

2016-04-11

: Pdf 1408123-509510-Ce Report 1408123-509510-CE_REPORT CertsReports 509510 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 67

Download1408123-509510-CE REPORT
Open PDF In BrowserView PDF
CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

EMC TEST REPORT
Authorized under Declaration of Conformity
According to
EN 55022 : 2010 / AC:2011
EN 61000-3-2: 2006+A2: 2009
EN 61000-3-3 : 2008

EN 55024 : 2010
IEC 61000-4-2 : 2008
IEC 61000-4-3 : 2006+A1:2007+A2:2010
IEC 61000-4-4 : 2012
IEC 61000-4-5 : 2005
IEC 61000-4-6 : 2008
IEC 61000-4-8 : 2009
IEC 61000-4-11 : 2004

Applicant

: Intracom Asia Co., Ltd

Address

:

Equipment

: Fast Ethernet PCI Network Card

Model No.

: 509510

Trademark

: Intellinet

‚
‚

4F., No.77, Sec.1, Xintai 5th Rd., Xizhi Dist., New Taipei City
221, Taiwan

The test result refers exclusively to the test presented test model / sample.
Without written approval of Cerpass Technology (Suzhou) Corp. the test report shall not
be reproduced except in full.

‚

This test report is only applicable to European Community.
The test report must not be used by the clients to claim product certification approval by
NVLAP or any agency of the Government.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 1 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

Contents
CERTIFICATE OF COMPLIANCE ....................................................................... 5
1. Summary of Test Procedure and Test Results .................................................... 6
2. Immunity Testing Performance Criteria Definition ................................................ 6
3. Test Configuration of Equipment under Test ...................................................... 7
3.1. Factory ............................................................................................................................................. 7
3.2. Feature of Equipment under Test..................................................................................................... 7
3.3. Test Manner ..................................................................................................................................... 7
3.4. Description of Test System............................................................................................................... 8
3.5. General Information of Test.............................................................................................................. 9
3.6. Measurement Uncertainty ................................................................................................................ 9
4. Test of Conducted Emission........................................................................10
4.1. Test Limit ........................................................................................................................................ 10
4.2. Test Procedures ............................................................................................................................. 11
4.3. Typical Test Setup .......................................................................................................................... 11
4.4. Measurement equipment ............................................................................................................... 12
4.5. Test Data and Result...................................................................................................................... 13
4.6. Test Photographs ........................................................................................................................... 17
5. Test of Radiated Emission .........................................................................19
5.1. Test Limit ........................................................................................................................................ 19
5.2. Test Procedures ............................................................................................................................. 20
5.3. Typical test Setup........................................................................................................................... 21
5.4. Measurement equipment ............................................................................................................... 22
5.5. Test Result and Data (30MHz ~ 1000MHz) ................................................................................... 23
5.6. Test Result and Data (1000MHz ~ 6000MHz) ............................................................................... 25
5.7. Test Photographs (30MHz ~ 1000MHz)......................................................................................... 27
5.8. Test Photographs (1000MHz ~ 6000MHz)..................................................................................... 28
6. Harmonics Test .....................................................................................29
6.1. Limits Of Harmonics Current Measurement................................................................................... 29
6.2. Measurement equipment ............................................................................................................... 29
6.3. Test Result and Data...................................................................................................................... 30
6.4. Test Photographs ........................................................................................................................... 34
7. Voltage Fluctuations Test ..........................................................................35
7.1. Test Procedure ............................................................................................................................... 35
7.2. Measurement equipment ............................................................................................................... 35
7.3. Test Result and Data...................................................................................................................... 36
7.4. Test Photographs ........................................................................................................................... 38
8. Electrostatic Discharge Immunity Test ...........................................................39
8.1. Test Procedure ............................................................................................................................... 39
8.2. Test Setup for Tests Performed in Laboratory................................................................................ 40
8.3. Test Severity Levels ....................................................................................................................... 41
8.4. Measurement equipment ............................................................................................................... 41
8.5. Test Result and Data...................................................................................................................... 42

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 2 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

8.6. Test Photographs ........................................................................................................................... 43
9. Radio Frequency electromagnetic field immunity test............................................44
9.1. Test Procedure ............................................................................................................................... 44
9.2. Test Severity Levels ....................................................................................................................... 45
9.3. Measurement equipment ............................................................................................................... 45
9.4. Test Result and Data...................................................................................................................... 46
9.5. Test Photographs ........................................................................................................................... 47
10. Electrical Fast Transient/ Burst Immunity Test .................................................48
10.1. Test Procedure............................................................................................................................ 48
10.2. Test Severity Levels .................................................................................................................... 49
10.3. Measurement equipment ............................................................................................................ 49
10.4. Test Result and Data................................................................................................................... 50
10.5. Test Photographs ........................................................................................................................ 51
11. Surge Immunity Test ...............................................................................52
11.1. Test Procedure............................................................................................................................ 52
11.2. Test Severity Level...................................................................................................................... 53
11.3. Measurement equipment ............................................................................................................ 53
11.4. Test Result and Data................................................................................................................... 54
11.5. Test Photographs ........................................................................................................................ 55
12. Conduction Disturbances induced by Radio-Frequency Fields....................................56
12.1. Test Procedure............................................................................................................................ 56
12.2. Test Severity Levels .................................................................................................................... 57
12.3. Measurement equipment ............................................................................................................ 57
12.4. Test Result and Data................................................................................................................... 58
12.5. Test Photographs ........................................................................................................................ 59
13. Power Frequency Magnetic Field Immunity Tests ................................................60
13.1. Test Setup ................................................................................................................................. 60
13.2. Test Severity Levels .................................................................................................................... 60
13.3. Measurement equipment ............................................................................................................ 60
13.4. Test Result and Data................................................................................................................... 61
14. Voltage Dips and Voltage Interruptions Immunity Test Setup ..................................62
14.1. Test Conditions ........................................................................................................................... 62
14.2. Measurement equipment ............................................................................................................ 62
14.3. Test Result and Data................................................................................................................... 63
14.4. Test Photographs ........................................................................................................................ 64
15. Photographs of EUT ................................................................................65

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 3 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

History of this test report
„ Original
… Additional attachment as following record:
Attachment No.

Date

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Description

Issued Date : Oct.31, 2014
Page No.

: 4 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

CERTIFICATE OF COMPLIANCE
According to
EN 55022 : 2010 / AC:2011
EN 61000-3-2: 2006+A2: 2009
EN 61000-3-3 : 2008

EN 55024 : 2010
IEC 61000-4-2 : 2008
IEC 61000-4-3 : 2006+A1:2007+A2:2010
IEC 61000-4-4 : 2012
IEC 61000-4-5 : 2005
IEC 61000-4-6 : 2008
IEC 61000-4-8 : 2009
IEC 61000-4-11 : 2004

Applicant

: Intracom Asia Co., Ltd

Address

:

Equipment

: Fast Ethernet PCI Network Card

Model No.

: 509510

Trademark

: Intellinet

4F., No.77, Sec.1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221,
Taiwan

I HEREBY CERTIFY THAT :
The measurements shown in this test report were made in accordance with the procedures
given in EUROPEAN COUNCIL DIRECTIVE 2004/108/EC& 2014/30/EU.
The test was carried out on Oct .23~31, 2014 at Cerpass Technology(Suzhou) Corp.

Signature

Miro Chueh/ Technical director

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 5 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

1. Summary of Test Procedure and Test Results
Test Item

Normative References

Test Result

Conducted Emission

EN55022:2010/AC:2011

PASS

Radiated Emission

EN55022:2010/AC:2011

PASS

Harmonics

EN 61000-3-2 : 2006+A2: 2009

PASS

Voltage Fluctuations

EN 61000-3-3: 2008

PASS

IEC 61000-4-2 : 2008

PASS

IEC 61000-4-3 : 2006+A1:2007+A2:2010

PASS

IEC 61000-4-4 : 2012

PASS

IEC 61000-4-5 : 2005

PASS

IEC 61000-4-6 : 2008

PASS

IEC 61000-4-8 : 2009

N/A

IEC 61000-4-11 : 2004

PASS

Electrostatic Discharge Immunity
Test (ESD)
Radio Frequency electromagnetic
field immunity test (RS)
Electrical Fast Transient/ Burst
Immunity Test (EFT)
Surge Immunity Test
Conduction Disturbances induced
by Radio-Frequency Fields
Power Frequency Magnetic Field
Immunity Test
Voltage Dips and Voltage
Interruptions Immunity Test

2. Immunity Testing Performance Criteria Definition
A.

Normal performance within limits specified by the manufacture, requestor or purchaser;

B.

Temporary loss of function or degradation of performance which ceases after the disturbance
ceases, and from which the equipment under test recovers its normal performance, without
operator intervention;

C. Temporary loss of function or degradation of performance, the correction of which requires
operation intervention;
D. Loss of function or degradation of performance which is not recoverable, owing to damage to
hardware or software, or loss of data.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 6 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

3. Test Configuration of Equipment under Test
3.1. Factory
Intracom Asia Co., Ltd
4F., No.77, Sec.1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221, Taiwan

3.2. Feature of Equipment under Test
Equipment

Fast Ethernet PCI Network Card

Model No:

509510

3.3. Test Manner

a

During testing, the interface cables and equipment positions were varied according to
Europe Standard.

b

The complete test system included auxiliary equipment and EUT for EMI test.

c

And then test.

The pre-test modes
Conducted Emission
Test Mode 1: Normal Link
(Power port)
Conducted Emission
ISN RJ45 10Mbps /100Mbps LINK 10%
(Telecom port)
Radiated Emission
Test Mode 1: Normal Link
EMS/H-F:
The worse case was selected as the final test mode and record in the report
Test Mode 1: Normal Link

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 7 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
3.4. Description of Test System
No

Device

Manufacturer

Model No.

Description

1

PC

DELL

Dell Optitle 380

N/A

2

Notebook

SONY

PCG-71811P

R33021

3

LCD Monitor

DELL

U3011T

R43004

4

Printer

HP

DESKJET 400

N/A

5

HDD

N/A

USB 3.0 HDD

N/A

6

USB Mouse

DELL

OXN967

R41108

7

USB Mouse

DELL

MG1090

R41108

8

USB Keyboard

DELL

SK-8115

T3A002

Use Cable:
No.

Cable

Quantity

A

RJ45

1

1m Shielded with two core

B

VGA Cable

1

1.8 Shielded with two core

C

USB Cable

1

1.8 Shielded

D

USB Cable

1

0.4 Unshielded

E

USB Cable

1

1.8 Unshielded

F

USB Cable

1

1.8 Unshielded

G

USB Cable

1

1.8 Unshielded

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Description

Issued Date : Oct.31, 2014
Page No.

: 8 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

3.5. General Information of Test
Test Site:

Cerpass Technology (Suzhou) Co.,Ltd
No.66,Tangzhuang Road, Suzhou Industrial Park, Jiangsu

Test Site Location :

215006, China

NVLAP LAB Code :

200814-0

FCC Registration Number :

916572, 331395

IC Registration Number :

7290A-1, 7290A-2
T-1945 for Telecommunication Test

VCCI Registration Number :

C-2919 for Conducted emission test
R-2670 for Radiated emission test below 1GHz
G-227 for Radiated emission test above 1GHz
Conducted Emission Test: from 150kHz to 30 MHz

Frequency Range

Radiated Emission Test: from 30 MHz to 1,000 MHz

Investigated :

Radiated Emission Test: from 1GHz to 6GHz
The test distance of radiated emission below 1GHz from
antenna to EUT is 10 M.

Test Distance :

The test distance of radiated emission above 1GHz from
antenna to EUT is 3 M.

LABORATORY ACCREDIATION

3.6. Measurement Uncertainty
Test results and Measurement uncertainty without any relationship in the test report.
Conducted Emission
The measurement uncertainty is evaluated as ± 2.71 dB.
Radiated Emission
(30MHz -1000MHz)
(1G-6GHz)

Horizontal

The measurement uncertainty is evaluated as ±3.59 dB.

Vertical

The measurement uncertainty is evaluated as ± 3.89 dB

Horizontal

The measurement uncertainty is evaluated as ± 2.31 dB.

Vertical

The measurement uncertainty is evaluated as ± 2.15 dB.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 9 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

4. Test of Conducted Emission
4.1. Test Limit
Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz and
return leads of the EUT according to the methods defined in European Standard EN 55022
Clause 9.

The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above

the ground plane as shown in section 5.2. The interface cables and equipment positioning were
varied within limits of reasonable applications to determine the position producing maximum
conducted emissions.

Table 1 Class B Line Conducted Emission Limits:
Frequency range
(MHz)

Quasi Peak

Average

0.15 to 0.50

66 to 56

56 to 46

0.50 to 5

56

46

5. to 30.

60

50

Limits (dB µ V)

Note 1: The lower limits shall apply at the transition frequencies.
Note 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to
0.50MHz.

Table 2 - Limits of conducted common mode (asymmetric mode) disturbance at
telecommunication ports in the frequency range 0.15 MHz to 30 MHz for class B equipment.
Frequency range
(MHz)

Voltage limits

Current limits

dB(μV)

dB(μA)

Quasi-peak

Average

Quasi-peak

Average

0.15 to 0.5

84 to 74

74 to 64

40 to 30

30 to 20

0.5 to 30

74

64

30

20

Note 1: The limits decrease linearly with the logarithm of the frequency in the range 0.15 to 0.5 MHz.
Note 2: The current and voltage disturbance limits are derived for use with an impedance stabilization
network (ISN) which presents a common mode (asymmetric mode) impedance of 150Ω to the
telecommunication under test (conversion factor is 20 log10 150/1 = 44dB).

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 10 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
4.2. Test Procedures

a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter
from the conducting wall of the shielding room and it was kept at least 0.8 meters from any other
grounded conducting surface.
b. Connect EUT to the power mains through a line impedance stabilization network (LISN).
c. All the support units are connecting to the other LISN.
d. The LISN provides 50 ohm coupling impedance for the measuring instrument.
e. The CISPR states that a 50 ohm, 50 micro-Henry LISN should be used.
f.

Both sides of AC line were checked for maximum conducted interference.

g. The frequency range from 150 kHz to 30 MHz was searched
h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum
Hold Mode.

4.3. Typical Test Setup
10cm

EUT

80cm
80cm
AE
80cm
40cm
LISN

ISN

LISN
40cm

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 11 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
4.4. Measurement equipment

100565

Calibration
Date
2014.03.24

2015.03.23

ESH2-Z5

100182

2014.09.11

2015.09.10

R&S

ENV216

100325

2013.12.04

2014.12.03

ISN

FCC

FCC-TLISN-T2-02

20379

2014.03.24

2015.03.23

ISN

FCC

FCC-TLISN-T4-02

20380

2014.03.24

2015.03.23

ISN

FCC

FCC-TLISN-T8-02

20381

2014.03.24

2015.03.23

ISN

TESEQ

ISN ST08

30175

2014.03.24

2015.03.23

Current Probe

R&S

EZ-17

100303

2014.04.04

2015.04.03

Passive Voltage Probe

R&S

ESH2-Z3

100026

2014.03.24

2015.03.23

Pulse Limiter

R&S

ESH3-Z2

100529

2014.03.24

2015.03.23

Temperature/ Humidity
Meter

Zhicheng

ZC1-11

CEP-TH-004

2014.03.31

2015.03.30

Instrument/Ancillary

Manufacturer

Model No.

Serial No.

Test Receiver

R&S

ESCI

AMN

R&S

Two-Line V-Network

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Valid Date.

Issued Date : Oct.31, 2014
Page No.

: 12 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
4.5. Test Data and Result
Test Mode :

Mode 1: Normal Link

AC Power :

AC 230V/50Hz

Phase :

LINE

Temperature :

22°C

Humidity :

50%

Pressure(mbar) :

1002

Date:

2014/10/23

No.

Frequency
(MHz)

Factor
(dB)

Reading
(dBuV)

Level
(dBuV)

Limit
(dBuV)

Margin
(dB)

Detector

1

0.1500

9.70

34.97

44.67

65.99

-21.32

QP

2

0.1500

9.70

32.59

42.29

56.00

-13.71

AVG

3

0.2100

9.69

39.67

49.36

63.20

-13.84

QP

4

0.2100

9.69

39.07

48.76

54.28

-5.52

AVG

5

0.3500

9.67

31.75

41.42

58.96

-17.54

QP

6

0.3500

9.67

29.86

39.53

50.28

-10.75

AVG

7

0.4220

9.67

27.83

37.50

57.41

-19.91

QP

8

0.4220

9.67

25.19

34.86

48.23

-13.37

AVG

9

1.3420

9.66

23.75

33.41

56.00

-22.59

QP

10

1.3420

9.66

18.47

28.13

46.00

-17.87

AVG

11

15.8660

10.02

30.06

40.08

60.00

-19.92

QP

12

15.8660

10.02

28.68

38.70

50.00

-11.30

AVG

Note: Measurement Level = Reading Level + Correct Factor+ Attenuator

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 13 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Test Mode :

Mode 1: Normal Link

AC Power :

AC 230V/50Hz

Phase :

NEUTRAL

Temperature :

22°C

Humidity :

50%

Pressure(mbar) :

1002

Date:

2014/10/23

No.

Frequency
(MHz)

Factor
(dB)

Reading
(dBuV)

Level
(dBuV)

Limit
(dBuV)

Margin
(dB)

Detector

1

0.1500

9.70

34.81

44.51

65.99

-21.48

QP

2

0.1500

9.70

32.40

42.10

56.00

-13.90

AVG

3

0.2100

9.69

39.68

49.37

63.20

-13.83

QP

4

0.2100

9.69

39.09

48.78

54.28

-5.50

AVG

5

0.3500

9.67

31.77

41.44

58.96

-17.52

QP

6

0.3500

9.67

29.94

39.61

50.28

-10.67

AVG

7

1.3099

9.66

22.47

32.13

56.00

-23.87

QP

8

1.3099

9.66

17.25

26.91

46.00

-19.09

AVG

9

13.9500

9.95

30.63

40.58

60.00

-19.42

QP

10

13.9500

9.95

30.34

40.29

50.00

-9.71

AVG

11

14.8460

9.98

29.71

39.69

60.00

-20.31

QP

12

14.8460

9.98

29.03

39.01

50.00

-10.99

AVG

Note: Measurement Level = Reading Level + Correct Factor+ Attenuator

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 14 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Test Mode :

ISN RJ45 10Mbps LINK 10%

AC Power :

AC 230V/50Hz

Phase :

10M

Temperature :

22°C

Humidity :

50%

Pressure(mbar) :

1002

Date:

2014/10/31

No.

Frequency
(MHz)

Factor
(dB)

Reading
(dBuV)

Level
(dBuV)

Limit
(dBuV)

Margin
(dB)

Detector

1

1.0820

19.61

29.24

48.85

74.00

-25.15

QP

2

1.0820

19.61

22.91

42.52

64.00

-21.48

AVG

3

3.6380

19.64

26.17

45.81

74.00

-28.19

QP

4

3.6380

19.64

16.70

36.34

64.00

-27.66

AVG

5

5.4660

19.66

3.82

23.48

74.00

-50.52

QP

6

5.4660

19.66

-1.03

18.63

64.00

-45.37

AVG

7

9.9060

19.78

21.51

41.29

74.00

-32.71

QP

8

9.9060

19.78

14.30

34.08

64.00

-29.92

AVG

9

12.5180

19.75

15.74

35.49

74.00

-38.51

QP

10

12.5180

19.75

9.82

29.57

64.00

-34.43

AVG

11

26.3020

19.84

23.44

43.28

74.00

-30.72

QP

12

26.3020

19.84

17.05

36.89

64.00

-27.11

AVG

Note: Measurement Level = Reading Level + Correct Factor+ Attenuator

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 15 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Test Mode :

ISN RJ45 100M LINK 10%

AC Power :

AC 230V/50Hz

Phase :

100M

Temperature :

22°C

Humidity :

50%

Pressure(mbar) :

1002

Date:

2014/09/15

No.

Frequency
(MHz)

Factor
(dB)

Reading
(dBuV)

Level
(dBuV)

Limit
(dBuV)

Margin
(dB)

Detector

1

7.9260

19.69

35.89

55.58

74.00

-18.42

QP

2

7.9260

19.69

32.62

52.31

64.00

-11.69

AVG

3

11.8940

19.76

35.76

55.52

74.00

-18.48

QP

4

11.8940

19.76

33.34

53.10

64.00

-10.90

AVG

5

16.2300

19.74

35.41

55.15

74.00

-18.85

QP

6

16.2300

19.74

34.38

54.12

64.00

-9.88

AVG

7

18.2500

19.78

36.94

56.72

74.00

-17.28

QP

8

18.2500

19.78

37.12

56.90

64.00

-7.10

AVG

9

23.1340

19.81

37.58

57.39

74.00

-16.61

QP

10

23.1340

19.81

37.78

57.59

64.00

-6.41

AVG

11

26.6180

19.85

36.74

56.59

74.00

-17.41

QP

12

26.6180

19.85

36.45

56.30

64.00

-7.70

AVG

Note: Measurement Level = Reading Level + Correct Factor+ Attenuator
Test engineer:

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 16 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
4.6.

Report No.: DECE1408123

Test Photographs

Front View

Rear View

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 17 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

ISN 10M&100M

Front View

Rear View

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 18 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

5. Test of Radiated Emission
5.1. Test Limit
Table – Limits for radiated disturbance of class B ITE at a measuring distance of 3 m
Frequency range

Quasi-peak limits

MHz

dB(μV/m)

30 to 230

40

230 to 1000

47

NOTE 1 The lower limit shall apply at the transition frequency.
NOTE 2 Additional provisions may be required for cases where interference occurs.
The EUT shall meet the limits of below Table when measured in accordance with the method
described in European Standard EN 55022 Clause 10 and the conditional testing procedure
described below.
Table – Limits for radiated disturbance of class B ITE at a measuring distance of 3 m
Frequency range

Average limit

Peak limits

GHz

dB(μV/m)

dB(μV/m)

1 to 3

50

70

3 to 6

54

74

NOTE The lower limit applies at the transition frequency.
• Conditional

testing procedure:

The highest internal source of an EUT is defined as the highest frequency generated or used
within the EUT or on which the EUT operates or tunes.
If the highest frequency of the internal sources of the EUT is less than 108 MHz, the
measurement shall only be made up to 1 GHz.
If the highest frequency of the internal sources of the EUT is between 108 MHz and 500 MHz, the
measurement shall only be made up to 2 GHz.
If the highest frequency of the internal sources of the EUT is between 500 MHz and 1 GHz, the
measurement shall only be made up to 5 GHz.
If the highest frequency of the internal sources of the EUT is above 1 GHz, the measurement
shall be made up to 5 times the highest frequency or 6 GHz, whichever is less.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 19 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

5.2. Test Procedures
a.

The EUT was placed on a relatable table top 0.8 meter above ground.

b.

The EUT was set 3/10 meters from the interference receiving antenna which was mounted
on the top of a variable height antenna tower.

c.

The table was rotated 360 degrees to determine the position of the highest radiation.

d.

The antenna is a half wave dipole and its height is varied between one meter and four
meters above ground to find the maximum value of the field strength both horizontal
polarization and vertical polarization of the antenna are set to make the measurement.

e.

For each suspected emission the EUT was arranged to its worst case and then tune the
antenna tower (from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the
maximum reading.

f.

Set the test-receiver system to Peak Detect Function and specified bandwidth with
Maximum Hold Mode.

g.

If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then
testing will be stopped and peak values of EUT will be reported, otherwise, the emissions
which do not have 3 dB margin will be repeated one by one using the quasi-peak method
and reported.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 20 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

5.3. Typical test Setup
Below 1GHz Test Setup

Above 1GHz Test Setup

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 21 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
5.4. Measurement equipment

100853

Calibration
Date
2014.03.01

2015.02.28

3113A05915

2014.03.01

2015.02.28

1579008

2013.11.27

2014.11.26

Instrument/Ancillary

Manufacturer

Model No.

Serial No.

EMI Test Receiver

R&S

ESCI

Preamplifier

HP

8447F

Preamplifier

FIELD

Ultra

Broadband
Antenna

Broad-Band Horn
Antenna
Spectrum Analyzer
Temperature/ Humidity
Meter

AFS44-00101800
-25-10P-44

Valid Date.

SCHAFFNER

CBL6112D

22241

2014.03.04

2015. 03.03

Sunol

DRH-118

A072913

2014.10.16

2014.10.15

Agilent

E4407B

MY45118947 2014.07.18

2015.07.17

VICHY

CTH-608

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

N/A

2014.03.04

2015.03.03

Issued Date : Oct.31, 2014
Page No.

: 22 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

5.5. Test Result and Data (30MHz ~ 1000MHz)
Test Mode :

Test Mode 1: Normal Link

AC Power :

AC 230V/50Hz

Ant. Polarization:

Horizontal

Temp :

23℃

Humidity :

52%

Pressure(mbar) :

1002

Date :

2014/10/23

No.

Frequency
(MHz)

Factor
(dB/m)

Reading
(dBuV)

Level
(dBuV/m)

Limit
(dBuV/m)

Margin
(dB)

Det.

Height
(cm)

Azimuth
(deg)

1

232.7300

-9.44

47.29

37.85

47.00

-9.15

peak

100

22

2

250.1900

-8.37

48.37

40.00

47.00

-7.00

peak

100

75

3

364.6500

-4.54

48.50

43.96

47.00

-3.04

peak

200

121

4

433.5200

-4.46

43.69

39.23

47.00

-7.77

peak

200

245

5

500.4500

-2.20

44.66

42.46

47.00

-4.54

peak

200

312

6

760.4100

1.78

39.00

40.78

47.00

-6.22

peak

200

88

Note: Measurement Level = Reading Level + Correct Factor

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 23 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Test Mode :

Test Mode 1: Normal Link

AC Power :

AC 230V/50Hz

Ant. Polarization:

Vertical

Temp :

23℃

Humidity :

52%

Pressure(mbar) :

1002

Date :

2014/10/23

No.

Frequency
(MHz)

Factor
(dB/m)

Reading
(dBuV)

Level
(dBuV/m)

Limit
(dBuV/m)

Margin
(dB)

Det.

Height
(cm)

Azimuth
(deg)

1

44.5500

-12.12

47.43

35.31

40.00

-4.69

peak

100

37

2

165.8000

-12.26

46.28

34.02

40.00

-5.98

peak

100

58

3

366.5900

-4.60

48.50

43.90

47.00

-3.10

peak

100

99

4

433.5200

-4.46

44.18

39.72

47.00

-7.28

peak

200

159

5

500.4500

-2.20

43.32

41.12

47.00

-5.88

peak

200

246

6

760.4100

1.78

37.58

39.36

47.00

-7.64

peak

100

6

Note: Measurement Level = Reading Level + Correct Factor

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 24 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
5.6. Test Result and Data (1000MHz ~ 6000MHz)

No.

Test Mode :

Test Mode 1: Normal Link

AC Power :

AC 230V/50Hz

Ant. Polarization:

Horizontal

Temp :

23℃

Humidity :

52%

Pressure(mbar) :

1002

Date :

2014/10/30

Frequency

Factor

Reading

Level

Limit

Margin

(MHz)

(dB/m)

(dBuV)

(dBuV/m)

(dBuV/m)

(dB)

1

1187.500

-10.46

53.34

42.88

70.00

-27.12

2

1312.500

-9.32

51.49

42.17

70.00

3

1425.000

-8.29

50.35

42.06

4

1500.000

-7.61

49.84

5

2487.500

-2.63

6

3200.000

1.82

Det.

Height

Azimuth

(cm)

(deg)

peak

100

116

-27.83

peak

100

128

70.00

-27.94

peak

100

356

42.23

70.00

-27.77

peak

100

301

44.03

41.40

70.00

-28.60

peak

100

283

42.25

44.07

74.00

-29.93

peak

100

140

Note: Measurement Level = Reading Level + Correct Factor

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 25 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Test Mode :

Test Mode 1: Normal Link

AC Power :

AC 230V/50Hz

Ant. Polarization:

Vertical

Temp :

23℃

Humidity :

52%

Pressure(mbar) :

1002

Date :

2014/10/30

No.

Frequency

Factor

Reading

Level

Limit

Margin

(MHz)

(dB/m)

(dBuV)

(dBuV/m)

(dBuV/m)

(dB)

1

1075.000

-11.49

58.12

46.63

70.00

-23.37

2

1275.000

-9.66

57.78

48.12

70.00

3

1375.000

-8.75

56.36

47.61

4

1437.500

-8.18

57.25

5

1475.000

-7.84

6

1475.000

7

1937.500

Det.

Height

Azimuth

(cm)

(deg)

peak

100

101

-21.88

peak

100

230

70.00

-22.39

peak

100

194

49.07

70.00

-20.93

peak

100

62

58.07

50.23

70.00

-19.77

peak

100

155

-7.84

38.62

30.78

50.00

-19.22

AVG

100

155

-5.09

52.26

47.17

70.00

-22.83

peak

100

32

Note: Measurement Level = Reading Level + Correct Factor

Test engineer:

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 26 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

5.7. Test Photographs (30MHz ~ 1000MHz)

Front View

Rear View

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 27 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

5.8. Test Photographs (1000MHz ~ 6000MHz)

Front View

Rear View

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 28 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

6. Harmonics Test
6.1.

Limits Of Harmonics Current Measurement
Limits for Class D equipment

Limits for Class A equipment
Harmonics

Max. Permissible

Harmonics

Max. Permissible

Max. Permissible

Order

harmonics

Order

harmonics current per

harmonics current

n

current

n

watt mA/W

A

A
Odd harmonics

Odd Harmonics only

3

2.30

3

3.4

2.30

5

1.14

5

1.9

1.14

7

0.77

7

1.0

0.77

9

0.40

9

0.5

0.40

11

0.33

11

0.35

0.33

13

0.21

13

0.30

0.21

15<=n<=39

0.15¯15/n

15<=n<=39

3.85/n

0.15 x15/n

Even harmonics
2

1.08

4

0.43

6

0.30

8<=n<=40

0.23¯8/n

NOTE:
i.

Class A and Class D are classified according to item section 5 of EN 61000-3-2.

ii.

According go section 7 of EN 61000-3-2, the above limits for all equipment except
for lighting equipment are for all applications having a rated power > 75 W and no
limits apply for equipment with a rated power up to and including 75 W.

6.2. Measurement equipment
NSG 1007-3

Calibration
Date
1330A03972 2014.10.15

2015.10.14

TESEQ

CCN 1000-1

1330A03972 2014.10.15

2015.10.14

mingle

ETH529

Instrument/Ancillary

Manufacturer

Model No.

Power Source
Harmonic & Flicker
Tester
Temperature/
Humidity Meter

TESEQ

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Serial No.

N/A

2014.11.06

Valid Date.

2015.11.05

Issued Date : Oct.31, 2014
Page No.

: 29 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

6.3. Test Result and Data
Basic Standard

:

EN 61000-3-2

Final Test Result

:

PASS

Test Mode

:

Mode 1: Normal Link

Temperature

:

22℃

Humidity

:

50 %

Atmospheric Pressure

:

100 kPa

Test Data

:

Oct.25,2014

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 30 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Harmonics – Class-D per Ed. 3.2 (2009)(Run time) incl. inter-harmonics

3

300

2

200

1

100

0

0

-1

-100

-2

-200

-3

-300

Current RMS(Amps)

Harmonics and Class D limit line

Voltage (Volts)

Current (Amps)

EUT: Fast Ethernet PCI Network Card
Tested by: Wayne
Test category: Class-D per Ed. 3.2 (2009) (European limits) Test Margin: 100
Test date: 2014-10-25
Start time: 16:56:57
End time: 17:12:18
Test duration (min): 15
Data file name: H-010605.cts_data
Comment: 509510
Customer: Intracom Asia Co., Ltd
Test Result: Pass
Source qualification: Normal
Current & voltage waveforms

European Limits

1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
4

8

12

16 20 24
Harmonic #

28

32

36

40

Test result: Pass Worst harmonic was #3 with 25.99% of the limit.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 31 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

Current Test Result Summary (Run time)
EUT: Fast Ethernet PCI Network Card
Tested by: Wayne
Test category: Class-D per Ed. 3.2 (2009) (European limits) Test Margin: 100
Test date: 2014-10-25
Start time: 16:56:57
End time: 17:12:18
Test duration (min): 15
Data file name: H-010605.cts_data
Comment: 509510
Customer: Intracom Asia Co., Ltd
Test Result: Pass
Source qualification: Normal
THC(A): 0.18
I-THD(%): 20.27
POHC(A): 0.000
POHC Limit(A): 0.089
Highest parameter values during test:
V_RMS (Volts): 230.50
Frequency(Hz): 50.00
I_Peak (Amps): 1.844
I_RMS (Amps): 0.932
I_Fund (Amps): 0.913
Crest Factor:
1.985
Power (Watts): 206.8
Power Factor: 0.963
Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

0.000
0.183
0.000
0.019
0.000
0.013
0.000
0.007
0.000
0.004
0.000
0.004
0.000
0.004
0.000
0.004
0.000
0.004
0.000
0.004
0.000
0.003
0.000
0.003
0.000
0.003
0.000
0.003
0.000
0.002
0.000
0.002
0.000
0.002
0.000
0.002
0.000
0.002
0.000

0.703

26.0

0.185

1.044

17.71

Pass

0.393

4.8

0.019

0.582

3.33

Pass

0.207

6.3

0.013

0.308

4.36

Pass

0.103

7.2

0.008

0.155

4.98

Pass

0.072

5.9

0.000

0.000

0.00

Pass

0.062

5.8

0.000

0.000

0.00

Pass

0.054

6.8

0.000

0.000

0.00

Pass

0.048

8.9

0.000

0.000

0.00

Pass

0.042

8.8

0.000

0.000

0.00

Pass

0.038

9.7

0.000

0.000

0.00

Pass

0.035

10.0

0.000

0.000

0.00

Pass

0.032

10.6

0.000

0.000

0.00

Pass

0.030

9.3

0.000

0.000

0.00

Pass

0.027

9.4

0.000

0.000

0.00

Pass

0.026

9.3

0.000

0.000

0.00

Pass

0.024

9.8

0.000

0.000

0.00

Pass

0.023

8.5

0.000

0.000

0.00

Pass

0.022

10.2

0.000

0.000

0.00

Pass

0.020

11.4

0.000

0.000

0.00

Pass

Note: Dynamic limits were applied for this test.
window as the maximum harmonics/limit ratio.

The highest harmonics values in the above table may not occur at the same

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 32 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

Voltage Source Verification Data (Run time)
EUT: Fast Ethernet PCI Network Card
Tested by: Wayne
Test category: Class-D per Ed. 3.2 (2009) (European limits) Test Margin: 100
Test date: 2014-10-25
Start time: 16:56:57
End time:17:12:18
Test duration (min): 15
Data file name: H-010605.cts_data
Comment: 509510
Customer: Intracom Asia Co., Ltd
Test Result: Pass
Source qualification: Normal
Highest parameter values during test:
Voltage (Vrms): 230.50
Frequency(Hz): 50.00
I_Peak (Amps): 1.844
I_RMS (Amps): 0.932
I_Fund (Amps): 0.913
Crest Factor:
1.985
Power (Watts): 206.8
Power Factor: 0.963
Harm#
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Harmonics V-rms

Limit V-rms

% of Limit

Status

0.078
0.464
0.051
0.021
0.023
0.047
0.018
0.069
0.018
0.034
0.014
0.018
0.004
0.015
0.011
0.010
0.014
0.011
0.013
0.006
0.006
0.008
0.004
0.006
0.004
0.008
0.004
0.007
0.003
0.004
0.002
0.006
0.003
0.005
0.002
0.005
0.002
0.005
0.006

0.461
2.074
0.461
0.922
0.461
0.691
0.461
0.461
0.461
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230
0.230

16.92
22.37
11.13
2.23
4.92
6.79
3.89
14.91
3.85
14.58
5.91
7.86
1.91
6.54
4.92
4.49
5.99
4.56
5.47
2.53
2.68
3.49
1.84
2.57
1.74
3.60
1.59
3.25
1.42
1.92
1.06
2.51
1.35
1.97
0.92
2.18
1.02
2.09
2.68

OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 33 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
6.4.

Report No.: DECE1408123

Test Photographs

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 34 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

7. Voltage Fluctuations Test
7.1. Test Procedure
The equipment shall be tested under the conditions of Clause 5.
The total impedance of the test circuit, excluding the appliance under test, but including the
internal impedance of the supply source, shall be equal to the reference impedance.

The

stability and tolerance of the reference impedance shall be adequate to ensure that the overall
accuracy of ±8% is achieved during the whole assessment procedure.

7.2. Measurement equipment

NSG 1007-3

Calibration
Date
1330A03972 2014.10.15

2015.10.14

TESEQ

CCN 1000-1

1330A03972 2014.10.15

2015.10.14

mingle

ETH529

Instrument/Ancillary

Manufacturer

Model No.

Power Source
Harmonic & Flicker
Tester
Temperature/
Humidity Meter

TESEQ

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Serial No.

N/A

2014.11.06

Valid Date.

2015.11.05

Issued Date : Oct.31, 2014
Page No.

: 35 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
7.3.

Report No.: DECE1408123

Test Result and Data
Basic Standard

:

EN 61000-3-3

Final Test Result

:

PASS

Test Mode

:

Mode 1: Normal Link

Temperature

:

22℃

Humidity

:

50%

Atmospheric Pressure

:

100 kPa

Test Data

:

Oct.25,2014

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 36 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
Flicker Test Summary per EN/IEC61000-3-3

Report No.: DECE1408123

(Run time)

EUT: Fast Ethernet PCI Network Card
Tested by: Wayne
Test category: All parameters (European limits)
Test Margin: 100
Test date: 2014-10-25
Start time: 17:20:12
End time: 17:30:33
Test duration (min): 10
Data file name: F-010606.cts_data
Comment: 509510
Customer: Intracom Asia Co., Ltd
Test Result: Pass
Status: Test Completed

Psti and limit line

European Limits

1.00

Pst

0.75
0.50
0.25
17:30:32

Plt and limit line

Plt

0.50
0.25
0.00
17:30:32

Parameter values recorded during the test:
Vrms at the end of test (Volt): 230.35
Highest dt (%):
0.00
Time(mS) > dt:
0.0
Highest dc (%):
0.00
Highest dmax (%):
0.00
Highest Pst (10 min. period):
0.064
Highest Plt (2 hr. period):
0.028

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Test limit (%):
Test limit (mS):
Test limit (%):
Test limit (%):
Test limit:
Test limit:

3.30
500.0
3.30
4.00
1.000
0.650

Pass
Pass
Pass
Pass
Pass
Pass

Issued Date : Oct.31, 2014
Page No.

: 37 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
7.4.

Report No.: DECE1408123

Test Photographs

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 38 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

8. Electrostatic Discharge Immunity Test
8.1. Test Procedure
a. In the case of air discharge testing the climatic conditions shall be within the following ranges:
- ambient temperature: 15℃ to 35℃;
- relative humidity : 30% to 60%;
- atmospheric pressure : 86 KPa (860 hPa) to 106 KPa (1060 hPa).
b. Test programs and software shall be chosen so as to exercise all normal modes of operation of
the EUT.

The use of special exercising software is encouraged, but permitted only where it

can be shown that the EUT is being comprehensively exercised.
c. The test voltage shall be increased from the minimum to the selected test severity level, in
order to determine any threshold of failure.

The final severity level should not exceed the

product specification value in order to avoid damage to the equipment.
d. The test shall be performed with both air discharge and contact discharge. On reselected
points at least 10 single discharges (in the most sensitive polarity) shall be applied on air
discharge. On reselected points at least 25 single discharges (in the most sensitive polarity)
shall be applied on contact discharge.
e. For the time interval between successive single discharges an initial value of one second is
recommended. Longer intervals may be necessary to determine whether a system failure has
occurred.
f. In the case of contact discharges, the tip of the discharge electrode shall touch the EUT before
the discharge switch is operated.
g. In the case of painted surface covering a conducting substrate, the following procedure shall
be adopted :
— If the coating is not declared to be an insulating coating by the equipment manufacturer,
then the pointed tip of the generator shall penetrate the coating so as to make contact with
the conducting substrate.
— Coating declared as insulating by the manufacturer shall only be submitted to the air
discharge.
— The contact discharge test shall not be applied to such surfaces.
h. In the case of air discharges, the round discharge tip of the discharge electrode shall be
approached as fast as possible (without causing mechanical damage) to touch the EUT . After
each discharge, the ESD generator (discharge electrode) shall be removed from the EUT. The
generator is then retriggered for a new single discharge. This procedure shall be repeated until
the discharges are completed. In the case of an air discharge test, the discharge switch, which
is used for contact discharge, shall be closed.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 39 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

8.2. Test Setup for Tests Performed in Laboratory

The test setup consists of the test generator, EUT and auxiliary instrumentation necessary to
perform DIRECT and INDIRECT application of discharges to the EUT as applicable, in the follow
manner :
a. Contact Discharge to the conductive surfaces and to coupling plane;
b. Air Discharge at insulating surfaces.
The preferred test method is that of type tests performed in laboratories and the only accepted
method of demonstrating conformance with this standard. The EUT was arranged as closely as
possible to arrangement in final installed conditions.
A ground reference plane was provided on the floor of the test site. It was a metallic sheet (copper
or aluminum) of 0.25 mm, minimum thickness; other metallic may be used but they shall have at
least 0.65 mm thickness. In the Exclusive Certification Corp., we provided 1 mm thickness
stainless steel ground reference plane. The minimum size of the ground reference plane is 2.5 m x
2.5 m, the exact size depending on the dimensions of the EUT. It was connected to the protective
grounding system.
The EUT was arranged and connected according to its functional requirements. A distance of 1m
minimum was provided between the EUT and the wall of the lab. and any other metallic structure.
In cases where this length exceeds the length necessary to apply the discharges to the selected
points, the excess length shall, where possible, be placed non-inductively off the ground reference
plane and shall not come closer than 0.2m to other conductive parts in the test setup.
Where the EUT is installed on a metal table, the table was connected to the reference plane via a cable
with a 470k ohm resister located at each end, to prevent a build-up of charge. The test setup was
consist a wooden table, 0.8m high, standing on the ground reference plane. A HCP, 1.6 m x 0.8 m, was
placed on the table. The EUT and cables was isolated from the HCP by an insulating support 0.5 mm
thick. The VCP size, 0.5 m x 0.5 m.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 40 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
8.3. Test Severity Levels
Contact Discharge
Level

Air Discharge

Test Voltage (kV) of

Level

Test Voltage (kV) of

Contact discharge

Air Discharge

1

±2

1

±2

2

±4

2

±4

3

±6

3

±8

4

±8

4

±15

X

Specified

X

Specified

Remark: “X” is an open level.

8.4. Measurement equipment

575

Calibration
Date
2014.03.03

2015.03. 02

N/A

2014.03.04

2015.03.03

Instrument/Ancillary

Manufacturer

Model No.

Serial No.

ESD Simulator

TESEQ

NSG437

VICHY

CTH-608

Temperature/
Humidity Meter

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Valid Date.

Issued Date : Oct.31, 2014
Page No.

: 41 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
8.5. Test Result and Data
Basic Standard

: IEC 61000-4-2

Final Test Result

: PASS

Pass performance criteria

: B

Temperature

±2 / ±4 / ±8 kV for air discharge,
±2 / ±4 kV for contact discharge
: 20°C

Relative Humidity

: 50 %

Atmospheric Pressure

: 100 kPa

Test Date

: Oct.27,2014

Test Voltage

:

Mode 1: Normal Link
Contact Discharge
25
Voltage
Point\Polarity

Air Discharge

times / each
6 kV
-

10

2 kV
+ -

+

4 kV
-

+

2 kV
+ -

4 kV
+ -

8 kV
+ -

10 kV
+ -

HCP

A

A

A

A

---

---

---

---

---

---

---

---

---

---

---

---

VCP

A

A

A

A

---

---

---

---

---

---

---

---

---

---

---

---

Screw

A

A

A

A

---

---

---

---

---

---

---

---

---

---

---

---

Case

A

A

A

A

---

---

---

---

---

---

---

---

---

---

---

---

NIC Port

---

---

---

---

---

---

---

---

A

A

A

A

A

A

---

---

+

8 kV
-

times / each

Test engineer:

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 42 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
8.6.

Report No.: DECE1408123

Test Photographs

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 43 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

9. Radio Frequency electromagnetic field immunity test
9.1. Test Procedure
a. The equipment to be tested is placed in the center of the enclosure on a wooden table. The
equipment is then connected to power and signal leads according to pertinent installation
instructions.
b. The antenna which is enabling the complete frequency range of 80-1000 MHz is placed
3m away from the equipment. The required field strength is determined by placing the field
strength meter(s) on top of or directly alongside the equipment under test and monitoring
the field strength meter via a remote field strength indicator outside the enclosure while
adjusting the continuous-wave to the applicable antennae.
c. The test is normally performed with the antenna facing the most sensitive side of the EUT.
The polarization of the field generated by the bucolical antenna necessitates testing each
position twice, once with the antenna positioned vertically and again with the antenna
positioned horizontally. The circular polarization of the field from the log-spiral antenna
makes a change of position of the antenna unnecessary.
d. At each of the above conditions, the frequency range is swept 80-1000 MHz, pausing to
adjust the R.F. signal level or to switch oscillators and antenna. The rate of sweep is in the
order of 1.5*10-3 decades/s. The sensitive frequencies or frequencies of dominant interest
may be discretely analyzed.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 44 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
9.2. Test Severity Levels
Frequency Band : 80-1000 MHz
Level

Test field strength (V/m)

1

1

2

3

3

10

X

Specified
Remark: “X” is an open class.

9.3. Measurement equipment

103287

Calibration
Date
2014.03.24

2015.03.23

NR P-Z91

100383

2014.03.24

2015.03.23

R&S

NRP-Z91

100384

2014.03.24

2015.03.23

Power Meter

R&S

NRP

101206

2014.03.24

2015.03.23

Power Amplifer

BONN

076659

2014.03.24

2015.03.23

HI-6105

137445

2014.09.03

2015.09.02

Instrument/Ancillary

Manufacturer

Model No.

Serial No.

Signal Generator

R&S

SML03

Power Sensor

R&S

Power Sensor

Istropic Electric Field EST.LINDGRE

BLWA0830-16
0/100/40D

Valid Date.

Probe

N

EMS Antenna

R&S

HL046E

100028

N/A

N/A

feiyan

N/A

101

2014.03.31

2015.03.30

Temperature/
Humidity Meter

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 45 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

9.4. Test Result and Data
Basic Standard

: IEC 61000-4-3

Final Test Result

: PASS

Pass performance criteria

: A

Frequency Range

: 80~1000 MHz

Temperature

: 22°C

Relative Humidity

: 52%

Atmospheric Pressure

: 100 kPa

Test Date

: Oct.31,2014

Mode 1: Normal Link
Modulation : AM 80% , 1KHz sine wave

,

Dwell time: 3 S

Frequency Step Size : 1 % of preceding frequency value
Frequency (MHz)

Antenna Polarization

face

Field strength (V/m)

Result

80~1000

Horizontal &Vertical

Front

3 V/m

A

80~1000

Horizontal &Vertical

Rear

3 V/m

A

80~1000

Horizontal &Vertical

Left

3 V/m

A

80~1000

Horizontal &Vertical

Right

3 V/m

A

Test engineer:

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 46 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
9.5.

Report No.: DECE1408123

Test Photographs

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 47 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

10. Electrical Fast Transient/ Burst Immunity Test
10.1. Test Procedure
a. In order to minimize the effect of environmental parameters on test results, the climatic
conditions when test is carrying out shall comply with the following requirements:
— ambient temperature: 15℃ to 35℃;
— relative humidity : 45% to 75%;
— Atmospheric pressure: 86 Kpa (860 hPa) to 106 Kpa (1060 hPa).
b. In order to minimize the effect of environmental parameters on test results, the
electromagnetic environment of the laboratory shall not influence the test results.
c. The variety and diversity of equipment and systems to be tested make it difficult to establish
general criteria for the evaluation of the effects of fast transients/bursts on equipment and
systems.
d. Test on Power Line:
— The EFT/B-generator was located on the GRP.. The length from the EFT/B-generator to
the EUT is not exceeding 1 m.
— The EFT/B-generator provides the ability to apply the test voltage in a non-symmetrical
condition to the power supply input terminals of the EUT.
e. Test on Communication Lines
— The coupling clamp is composed of a clamp unit for housing the cable (length more
than 3 m), and was placed on the GRP.
— The coupling clamp provides the ability of coupling the fast transient/bursts to the cable
under test.
f. The test results may be classified on the basic of the operating conditions and the functional
specification of the equipment under test, according to the following performance criteria :
— Normal performance within the specification limits.
— Temporary degradation or loss of function or performance which is self-recoverable.
— Temporary degradation or loss of function or performance which requires operator
intervention or system reset.
— Degradation or loss of function which is not recoverable due to damage of equipment
(components).

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 48 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

10.2. Test Severity Levels
The following test severity levels are recommended for the fast transient/burst test :
Open circuit output test voltage ± 10%
Level

On Power Supply

On I/O signal, data and control line

1

0.5 kV

0.25 kV

2

1.0 kV

0.50 kV

3

2.0 kV

1.00 kV

4

4.0 kV

2.00 kV

X

Specified

Specified

Remark : “ X ” is an open level. The level is subject to negotiation between the user and
the manufacturer or is specified by the manufacturer.

10.3. Measurement equipment

901

Calibration
Date
2014.03.24

2015.03.23

EMCPARTNER CDN2000-06-32

121

2014.03.24

2015.03.23

EMCPARTNER

CN-EFT1000

547

2014.03.24

2015.03.23

Zhicheng

ZC1-11

CEP-TH-005 2014.03.31

2015.03.30

Instrument/Ancillary

Manufacturer

Model No.

Serial No.

TRANSIENT

EMCPARTNER

TRA2000IN6

CDN
Coupling clamp
Temperature/ Humidity
Meter

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Valid Date.

Issued Date : Oct.31, 2014
Page No.

: 49 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
10.4.

Test Result and Data
Basic Standard

:

IEC 61000-4-4

Final Test Result

:

PASS

Pass performance criteria

:

B

Test Voltage

:

On Power Supply -- ±1.0 kV
On I/O signal, data and control line -- ±0.5 kV

Temperature

:

21°C

Relative Humidity

:

51 %

Atmospheric Pressure

:

100 kPa

Test Date

:

Oct.27,2014

Mode 1: Normal Link
Pulse : 5/50 ns

Repetition Rate: 5 kHz

Burst : 15m/300ms
Test time : 1 min/each condition
Voltage/ Mode/ Polarity/ Result/ Phase

Power Line

Signal Line

0.5 kV

1.0 kV

+

-

+

-

L

---

---

A

A

N

---

---

A

A

L-N

---

---

A

A

PE

---

---

A

A

L-PE

---

---

A

A

N-PE

---

---

A

A

L-N-PE

---

---

A

A

RJ 45

A

A

---

---

Test engineer:

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 50 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
10.5.

Report No.: DECE1408123

Test Photographs

LAN

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 51 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

11. Surge Immunity Test
11.1. Test Procedure
a. Climatic conditions
The climatic conditions shall comply with the following requirements :
— ambient temperature : 15 ℃ to 35 ℃
— relative humidity : 10 % to 75 %
— atmospheric pressure : 86 kPa to 106 kPa ( 860 hPa to 1060 hPa )
b. Electromagnetic conditions
the electromagnetic environment of the laboratory shall not influence the test results.
c. The test shall be performed according the test plan that shall specify the test set-up with
— generator and other equipment utilized;
— test level ( voltage/current );
— generator source impedance;
— internal or external generator trigger;
— number of tests : at least five positive and five negative at the selected points;
— repetition rate : maximum 1/min.
— inputs and outputs to be tested;
— representative operating conditions of the EUT;
— sequence of application of the surge to the circuit;
— phase angle in the case of AC. power supply;
— actual installation conditions, for example :
AC : neutral earthed,
DC : ( + ) or ( - ) earthed to simulated the actual earthing conditions.
d. If not otherwise specified the surges have to be applied synchronized to the voltage phase
at the zero-crossing and the peak value of the AC. voltage wave ( positive and negative ).
e. The surges have to be applied line to line and line(s) and earth.

When testing line to earth,

the test voltage has to be applied successively between each of the lines and earth, if there
is no other specification.
f.

The test procedure shall also consider the non-linear current-voltage characteristics of the
equipment under test. Therefore the test voltage has to be increased by steps up to the
test level specified in the product standard or test plan.

g. All lower levels including the selected test level shall be satisfied.

For testing the

secondary protection, the output voltage of the generator shall be increased up to the
worst-case voltage breakdown level ( let-through level ) of the primary protection.
h. If the actual operating signal sources are not available, that may be simulated. Under no
circumstances may the test level exceed the product specification. The test shall be carried
out according to a test plan.
i.

To find all critical points of the duty cycle of the equipment, a sufficient number of positive
and negative test pulses shall be applied.

For acceptance test previously unstressed

equipment shall be used to the protection devices shall be replaced.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 52 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
11.2. Test Severity Level
Level

Open-circuit test voltage, ± 10%, kV

1

0.5

2

1.0

3

2.0

4

4.0

X

Specified

NOTE: “X” is an open class. This level can be specified in the product specification.

11.3. Measurement equipment

901

Calibration
Date
2014.03.24

2015.03.23

021

2014.03.24

2015.03.23

121

2014.03.24

2015.03.23

CEP-TH-005 2014.03.31

2015.03.30

Instrument/Ancillary

Manufacturer

Model No.

Serial No.

TRANSIENT

EMCPARTNER

TRA2000IN6

CDN

EMCPARTNER

CDN-UTP8

CDN

EMCPARTNER CDN2000-06-32

Temperature/
Humidity Meter

Zhicheng

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

ZC1-11

Valid Date.

Issued Date : Oct.31, 2014
Page No.

: 53 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
11.4. Test Result and Data
Basic Standard

:

IEC 61000-4-5

Final Test Result

:

PASS

Pass performance criteria

:

B

Test Voltage

:

Temperature

:

21°C

Relative Humidity

:

51 %

Atmospheric Pressure

:

100 kPa

Test Date

:

Oct.27,2014

Input AC Power Port --

±0.5/1.0 kV for Line to Line
±0.5/1.0 /2.0kV for Line to Ground

Power Port
Mode 1: Normal Link
Test Voltage:230V/50Hz
Waveform : 1.2/50μs(8/20μs)

Repetition rate : 60 sec

Time : 20 time/each condition

/Phase Voltage / Mode / Polarity / Result

0°

90°

180°

270°

+

A

A

A

A

-

A

A

A

A

+

A

A

A

A

-

A

A

A

A

+

A

A

A

A

-

A

A

A

A

0.5/1.0 kV

L-N

L-PE
0.5/1.0/2.0kV
N-PE

Waveform :10/700μs

Repetition rate : 60 sec

Time : 5 time/each condition

Voltage

0.5 kV

1 kV

Mode / Polarity / Result

+

-

+

-

RJ45

A

A

B

B

Test engineer:

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 54 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

11.5. Test Photographs

LAN

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 55 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

12. Conduction Disturbances induced by Radio-Frequency Fields
12.1. Test Procedure
a. The EUT shall be operated within its intended climatic conditions.

The temperature

and relative humidity should be recorded.
b. This test method test can be performed without using a sell shielded enclosure.

This is

because the disturbance levels applied and the geometry of the setups are not likely to
radiated a high amount of energy, especially at the lower frequencies. If under certain
circumstances the radiated energy is too high, a shielded enclosure has to be used.
c. The test shall be performed with the test generator connected to each of the coupling
and decoupling devices in turn while the other non-excited RF-input ports of the
coupling devices are terminated by a 50 ohm load resistor.
d. The frequency range is swept from 150 KHz to 80 MHz, using the signal levels
established during the setting process, and with the disturbance signal 80% amplitude
modulated with a 1KHz sign wave, pausing to adjust the RF-signal level or to switch
coupling devices as necessary. The rate of sweep shall no exceed 1.5 x 10-3 decades/s.
Where the frequency is swept incrementally, the step size shall no exceed 1% of the
start and thereafter 1% of the preceding frequency value.
e. The dwell time at each frequency shall not be less than the time necessary for the EUT
to be exercised, and able to respond. Sensitive frequencies e.g. clock frequency (ies)
and harmonics or frequencies of dominant interest shall be analyzed separately.
f.

An alternative test procedure may be adopted, wherein the frequency range is swept
incrementally, with a step size not exceeding 4% of the start ad thereafter 4% of the
preceding frequency value.

The test level should be at least twice the value of the

specified test level.
g. In cases of dispute, the test procedure using a step size not exceeding 1% of the start
and thereafter 1% of preceding frequency value shall take precedence.
h. Attempts should be made to fully exercise the EUT during testing, and to fully
interrogate all exercise modes selected for susceptibility.
i.

The use of special exercising programs is recommended.

j.

Testing shall be performed according to a Test Plan, which shall be included in the test
report.

k. It may be necessary to carry out some investigatory testing in order to establish some
aspects of the test plan.

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 56 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
12.2. Test Severity Levels
Level

Voltage Level ( EMF ),

1

1V

2

3V

3

10 V

x

Specified

NOTE - x is an open class. This level can be specified in the product specification.

12.3. Measurement equipment
Manufacturer

Model No.

Serial No.

Calibration
Date

Valid Date.

FRANKONIA

CIT-10/75

102D1294

2014.03.24

2015.03.23

EM Injection clamp

FCC

F-203I-23MM

536

2014.03.24

2015.03.23

CDN

FRANKONIA

CDN-T2

A3010029

2014.03.24

2015.03.23

CDN

FRANKONIA

CDN-T4

A3015017

2014.03.24

2015.03.23

CDN

FRANKONIA

CDN-T8

A3022010

2014.03.24

2015.03.23

CDN

FRANKONIA

CDN-M2

A3002037

2014.03.24

2015.03.23

CDN

FRANKONIA

CDN-M2+M3

A3011102

2014.03.24

2015.03.23

CDN

FCC

CDN-M5/32

A3013024

2014.03.24

2015.03.23

6 dB Attenuator

FRANKONIA

N/A

N/A

2014.03.24

2015.03.23

Zhicheng

ZC1-11

CEP-TH-005 2014.03.31

2015.03.30

Instrument/Ancillary
Conducted immunity
test system

Temperature/
Humidity Meter

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 57 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
12.4. Test Result and Data
Basic Standard

: IEC 61000-4-6

Final Test Result

: PASS

Pass performance criteria

: A

Coupling mode

:

Temperature

: 21°C

Relative Humidity

: 51%

Atmospheric Pressure

: 100 kPa

Test Date

: Oct.27,2014

CDN-(M2+M3) for AC power ports
CDN-T4 for signal ports
EM-Clamp for signal ports

Test Mode 1: Normal Link
Frequency : 0.15~80MHz,

Modulation : AM 80%,1KHz sine wave,

Dwell time: 2.9s

Frequency Step Size : 1 % of preceding frequency value
Frequency

Test mode

Voltage(V)

Result

0.15 ~ 100MHz

Power(M3)

3

A

0.15 ~ 100MHz

RJ45

3

A

Test engineer:

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 58 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

12.5. Test Photographs

LAN

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 59 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

13. Power Frequency Magnetic Field Immunity Tests
13.1. Test Setup

GPR

:

Ground plane

C1

:

Power supply circuit

A

:

Safety earth

C2

:

Signal circuit

S

:

Insulating support

L

:

Communication line

EUT

:

Equipment under test

B

:

To power supply source

Lc

:

Induction coil

D

:

To signal source, simulator

E

:

Earth terminal

G

:

To the test generator

13.2. Test Severity Levels
Level

Magnetic field strength
A/m
1
3
10
30
100
special

1
2
3
4
5
X1)

NOTE 1 “X” is an open level. This level can be givenin the product specification.

13.3. Measurement equipment
Instrument/Ancillary

Manufacturer

Model No.

Serial No.

Calibration
Date

Valid Date.

TRANSIENT

EMCPARTNER

TRA2000IN6

901

2014.03.09

2015.03.08

H-Filed-Loop

EMCPARTNER

MF1000-1

144

2014.03.09

2015.03.08

Temperature/ Humidity
Meter

Zhicheng

ZC1-11

CEP-TH-005

2014.03.09

2015.03.08

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 60 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

13.4. Test Result and Data
Not Applicable

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 61 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

14. Voltage Dips and Voltage Interruptions Immunity Test Setup
14.1. Test Conditions
1. Source voltage and frequency : 230V / 50Hz, Single phase.
2. Test of interval : 10 sec.
3. Level and duration : Sequence of 3 dips/interrupts.
4. Voltage rise (and fall) time : 1 ∼ 5 μs.
5. Test severity :

Voltage dips and Interrupt reduction (%)

Test Duration
(period)

>95%

250

30%

25

>95%

0.5

14.2. Measurement equipment
Instrument/Ancillary

Manufacturer

Model No.

Serial No.

Calibration
Date

Valid Date.

TRANSIENT

EMCPARTNER

TRA2000IN6

901

2014.03.24

2015.03.23

Zhicheng

ZC1-11

CEP-TH-005 2014.03.31

2015.03.30

Temperature/ Humidity
Meter

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 62 of 67

Report No.: DECE1408123

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD
14.3. Test Result and Data
Basic Standard

: IEC 61000-4-11

Final Test Result

: PASS

Pass performance Criteria

: C for voltage interruption, B for voltage dips

Required performance Criteria : C for voltage interruption, B/C for voltage dips
Temperature

: 21°C

Relative Humidity

: 51%

Atmospheric Pressure

: 100 kPa

Test Date

: Oct.27,2014

Test Mode 1: Normal Link
Voltage(UT): AC 230 V 50 Hz
Test mod
Voltage
interruptions
Voltage dips

Test level
UT %

Interval(s) : 10s Times :
Durations
(period /
0
45
ms )

3
Phase / Result
90

135

180

225

270

315

>95%

250

C

C

C

C

C

C

C

C

30%

25

B

B

B

B

B

B

B

B

>95%

0.5

B

B

B

B

B

B

B

B

Test engineer:

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 63 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

14.4. Test Photographs

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 64 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

Report No.: DECE1408123

15. Photographs of EUT
1)

EUT Photo

2)

EUT Photo

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 65 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

3)

EUT Photo

4)

EUT Photo

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Report No.: DECE1408123

Issued Date : Oct.31, 2014
Page No.

: 66 of 67

CERPASS TECHNOLOGY (SUZHOU)CO.,LTD

5)

Report No.: DECE1408123

EUT Photo

Cerpass Technology (Suzhou) Co., Ltd
TEL: +86-512-6917-5888 FAX: +86-512-6917-5666

Issued Date : Oct.31, 2014
Page No.

: 67 of 67



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2014:11:03 18:27:12+08:00
Create Date                     : 2014:11:03 18:22:41+08:00
Metadata Date                   : 2014:11:03 18:27:12+08:00
Format                          : application/pdf
Title                           : Microsoft Word - 1408123-509510-CE REPORT.doc
Creator                         : karent
Document ID                     : uuid:72c23327-d29c-4343-b114-1dba98b0f8ca
Instance ID                     : uuid:4f61b542-f376-4ce4-8948-e979575ee33f
Page Count                      : 67
Author                          : karent
EXIF Metadata provided by EXIF.tools

Navigation menu