Volume 2 Tab Brochure
2016-10-27
: Pdf 141969-Brochure 141969-Brochure B6 unilog
Open the PDF directly: View PDF .
Page Count: 223
Download | |
Open PDF In Browser | View PDF |
Transformers Dry-Type Transformer Family 2.1 NEMA TP-1 Energy-Efficient Transformers Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 NEMA Premium and E3 Super Efficient Transformers NEMA Premium® Efficient Transformers . . . . . . . . . . . . . . . . . . . . . . E3 Super Efficient Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 V2-T2-111 V2-T2-119 V2-T2-124 V2-T2-127 V2-T2-130 V2-T2-133 V2-T2-144 V2-T2-173 Transformer Standards, Technical Data and Accessories Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Options and Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary of Transformer Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frequently Asked Questions About Transformers. . . . . . . . . . . . . . . . 2.7 V2-T2-93 V2-T2-93 V2-T2-93 V2-T2-93 V2-T2-94 V2-T2-94 V2-T2-109 V2-T2-109 Distribution Transformers Motor Drive Isolation Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers . . . . . . . . . . . . . . . . . . Class I, Division 2, Hazardous Location Transformers . . . . . . . . . . . . . Open-Type Core and Coil Assembly Transformers . . . . . . . . . . . . . . . Marine Duty Transformers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Buck-Boost and Low Voltage Lighting Transformers . . . . . . . . . . . . . . Medium Voltage Distribution Transformers. . . . . . . . . . . . . . . . . . . . . 2.6 V2-T2-71 V2-T2-71 V2-T2-72 V2-T2-72 V2-T2-73 V2-T2-89 V2-T2-89 General-Purpose Encapsulated Transformers Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 V2-T2-61 V2-T2-66 Energy-Efficient Harmonic Mitigating Transformers Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 V2-T2-2 V2-T2-2 V2-T2-3 V2-T2-3 V2-T2-4 V2-T2-4 V2-T2-50 V2-T2-50 V2-T2-186 V2-T2-187 V2-T2-189 V2-T2-191 V2-T2-195 V2-T2-211 V2-T2-214 Dimensions Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T2-216 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-1 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Contents Type DT-3 Description 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Product Description Application Description Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. NEMA TP-1-2002 compliant energy-efficient transformers are specifically designed to meet the energy efficiency standards set forth in NEMA Standards publication, TP-12002, “Guide for Determining Energy Efficiency for Distribution Transformers.” Surveys have shown that the average loading of low voltage dry-type distribution transformers, over a 24-hour period, is approximately 35%. NEMA TP-1 compliant transformers are optimized to offer maximum efficiency at 35% of nameplate rating. Types DS-3, DT-3 ● ● 2 2 2 2 2 2 2 Page NEMA TP-1 Energy-Efficient Transformers Features, Benefits and Functions. . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Single-Phase Aluminum . . . . . . . . . . . . . . . . Single-Phase Copper . . . . . . . . . . . . . . . . . . . Single-Phase Shielded Aluminum . . . . . . . . . Single-Phase Shielded Copper . . . . . . . . . . . Three-Phase Aluminum . . . . . . . . . . . . . . . . . Three-Phase Copper . . . . . . . . . . . . . . . . . . . Three-Phase Shielded Aluminum . . . . . . . . . Three-Phase Shielded Copper . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . K-Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum . . . . . . . . . . . . . . . . . . . . . . . . . . . Copper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ● ● ● ● ● Ventilated, NEMA 2 enclosure standard Suitable for indoor applications, outdoors when weathershields are also installed Upright mounting only 220ºC insulation system 150ºC rise standard; 115°C or 80°C rise optional Available in single-phase ratings 15–167 kVA, 600 volts primary (DS-3) Available in three-phase ratings 15–1500 kVA and up to 600 volts primary (DT-3) 2 The range of products covered by NEMA TP-1-2002 are: 2 ● ● ● ● ● ● ● ● NEMA TP-1-2002 Product Range Rating ● Voltage Class Voltage Primary voltage 34.5 kV and below Secondary voltage 600V and below ● Dry-Type Single-phase 10–833 kVA Rating Three-phase 15–2500 kVA 2 Transformers that are currently specifically excluded from the scope of NEMA Standard TP-1-2002 include: Liquid Rating ● ● ● ● ● Liquid-filled transformers below 10 kVA Dry-type transformers below 15 kVA AC and DC drives transformers Rectifier transformers designed for high harmonics Autotransformers Non-distribution transformers, such as UPS transformers Special impedance or regulation transformers Regulating transformers Sealed and non-ventilated transformers Machine tool transformers Welding transformers Transformers with tap ranges greater than 15% Transformers with a frequency other than 60 Hz Grounding transformers Testing transformers Single-phase 10–833 kVA Three-phase 15–2500 kVA 2 2 V2-T2-2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-3 V2-T2-3 V2-T2-4 V2-T2-4 V2-T2-4 V2-T2-6 V2-T2-8 V2-T2-10 V2-T2-12 V2-T2-23 V2-T2-34 V2-T2-42 V2-T2-50 V2-T2-50 V2-T2-51 V2-T2-52 V2-T2-57 Efficiency levels set forth in NEMA TP-1-2002. NEMA TP-1-2002 Efficiency Levels Tables of Energy Efficiency NEMA Class 1 Efficiency Levels Dry-Type Distribution Transformers— Low Voltage (600V and below) Single-Phase Three-Phase kVA Efficiency kVA Efficiency 15 97.7 15 97.0 25 98.0 30 97.5 37.5 98.2 45 97.7 50 75 98.0 98.3 75 98.5 112.5 98.2 100 98.6 150 98.3 167 98.7 225 98.5 250 98.8 300 98.6 333 98.9 500 98.7 — — 750 98.8 — — 1000 98.9 Transformers NEMA TP-1 Energy-Efficient Transformers Features, Benefits and Functions ● ● ● ● 60 Hz operation (except as noted) Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels Meet federal energy efficiency requirements for low voltage dry-type distribution transformers effective as of January 1, 2007 2.1 Standards and Certifications ● 2 2 UL® listed 2 2 Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. 2 2 2 2 2 Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the Uniform Building Code (UBC), International Building Code (IBC) and California Code Title 24. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-3 2.1 2 2 2 2 Transformers NEMA TP-1 Energy-Efficient Transformers Catalog Number Selection Please refer to Section 2.7 Page V2-T2-187. Product Selection Additional Product Selection information begins on Page V2-T2-189. Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 208 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DS-3 150 816 260A 226 (103) WS11 T29M11S15EE 2 25 2 at +2.5% 4 at –2.5% DS-3 150 818 260A 346 (157) WS11 T29M11S25EE 37.5 2 at +2.5% 4 at –2.5 DS-3 150 818 260A 374 (170) WS11 T29M11S37EE 2 50 2 at +2.5% 4 at –2.5% DS-3 150 819 260A 545 (247) WS16 T29M11S50EE 75 1 at +5% 2 at –5% DS-3 150 819 551A 568 (258) WS16 T29R11S75EE 2 100 1 at +5% 2 at –5% DS-3 150 814E 449A 1178 (535) WS13 T29R11S99EE 2 2 Full Capacity Taps 240 x 480 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 2 DS-3 150 842 3XA 196 (89) WS45 T20P11S15AEE 2 25 2 2 DS-3 150 842 3XA 261 (118) WS45 T20P11S25AEE 37.5 2 2 DS-3 150 843 3XA 304 (138) WS43 T20P11S37AEE 2 50 2 2 DS-3 150 843 3XA 396 (180) WS43 T20P11S50AEE 75 2 2 DS-3 150 844 3XA 688 (312) WS44 T20P11S75AEE 2 100 2 2 DS-3 150 844 3XA 699 (317) WS44 T20P11S99AEE 2 167 2 at +2.5% 4 at –2.5% DS-3 150 814E 288A 1294 (587) WS13 T48M11S67EE 3 15 2 2 DS-3 115 816 3XA 246 (112) WS11 T20P11F15EE 2 25 2 2 DS-3 115 818 3XA 373 (169) WS11 T20P11F25EE 37.5 2 2 DS-3 115 818 3XA 380 (173) WS11 T20P11F37EE 2 50 2 2 DS-3 115 819 3XA 590 (268) WS16 T20P11F50EE 2 2 2 75 DS-3 115 820 3XA 691 (314) WS16 T20P11F75EE 100 2 2 DS-3 115 821 3XA 844 (383) WS13 T20P11F99EE 2 15 2 2 DS-3 80 818 3XA 360 (163) WS11 T20P11B15EE 25 2 2 DS-3 80 818 3XA 370 (168) WS11 T20P11B25EE 2 37.5 2 2 DS-3 80 819 3XA 565 (257) WS16 T20P11B37EE 50 2 2 DS-3 80 820 3XA 680 (309) WS16 T20P11B50EE 75 2 2 DS-3 80 821 3XA 900 (409) WS13 T20P11B75EE 2 2 2 2 2 Notes 1 Weights subject to change. 2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary. 3 480 volt primary only. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 V2-T2-4 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 2 277 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DS-3 150 816 262C 220 (100) WS11 T27M11S15EE 25 2 at +2.5% 4 at –2.5% DS-3 150 818 262C 346 (157) WS11 T27M11S25EE 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 262C 391 (178) WS11 T27M11S37EE 50 2 at +2.5% 4 at –2.5% DS-3 150 819 262C 555 (252) WS16 T27M11S50EE 75 1 at +5% 2 at –5% DS-3 150 819 2 568 (258) WS16 T27R11S75EE 100 1 at +5% 2 at –5% DS-3 150 814E 2 1178 (535) WS13 T27R11S99EE 2 2 2 2 2 2 208 x 416 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 3 3 DS-3 150 816 3XF 246 (112) WS11 T18P11S15EE 25 3 3 DS-3 150 818 3XF 359 (163) WS11 T18P11S25EE 37.5 3 3 DS-3 150 818 3XF 374 (170) WS11 T18P11S37EE 50 3 3 DS-3 150 819 3XF 555 (252) WS16 T18P11S50EE 75 3 3 DS-3 150 820 3XF 665 (302) WS16 T18P11S75EE 100 3 3 DS-3 150 821 3XF 841 (382) WS13 T18P11S99EE 2 2 2 2 2 2 600 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DS-3 150 816 262B 243 (110) WS11 T60M11S15EE 25 2 at +2.5% 4 at –2.5% DS-3 150 818 262B 355 (161) WS11 T60M11S25EE 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 262B 375 (170) WS11 T60M11S37EE 50 2 at +2.5% 4 at –2.5% DS-3 150 819 262B 594 (270) WS16 T60M11S50EE 75 2 at +2.5% 4 at –2.5% DS-3 150 820 262B 755 (343) WS16 T60M11S75EE 100 2 at +2.5% 4 at –2.5% DS-3 150 821 262B 865 (393) WS13 T60M11S99EE 2 2 2 2 2 Notes 1 Weights subject to change. 2 Contact your local Eaton sales office for these details. 3 1 at +5%, 2 at –5% at 208 volts primary; 2 at +2.5%, 4 at –2.5% at 416 volts primary. 2 2 For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-5 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 208 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DS-3 150 816 260A 275 (125) WS11 T29M11S15CUEE 2 25 2 at +2.5% 4 at –2.5% DS-3 150 818 260A 390 (177) WS11 T29M11S25CUEE 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 260A 440 (200) WS11 T29M11S37CUEE 2 50 2 at +2.5% 4 at –2.5% DS-3 150 819 260A 661 (300) WS16 T29M11S50CUEE 75 1 at +5% 2 at –5% DS-3 150 820 551A 805 (365) WS16 T29R11S75CUEE 2 100 1 at +5% 2 at –5% DS-3 150 821 449A 970 (440) WS13 T29R11S99CUEE Full Capacity Taps 2 240 x 480 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 2 DS-3 150 816 3XA 270 (123) WS11 T20P11S15CUEE 2 25 2 2 DS-3 150 818 3XA 406 (184) WS11 T20P11S25CUEE 37.5 2 2 DS-3 150 818 3XA 453 (206) WS11 T20P11S37CUEE 2 50 2 2 DS-3 150 819 3XA 657 (298) WS16 T20P11S50CUEE 75 2 2 DS-3 150 820 3XA 803 (365) WS16 T20P11S75CUEE 2 100 2 2 DS-3 150 821 3XA 960 (436) WS13 T20P11S99CUEE 2 167 2 at +2.5% 4 at –2.5% DS-3 150 814E 288A 1665 (756) WS13 T48M11S67CUEE 3 15 2 2 DS-3 115 816 3XA 264 (120) WS11 T20P11F15CUEE 2 25 2 2 DS-3 115 818 3XA 420 (191) WS11 T20P11F25CUEE 37.5 2 2 DS-3 115 818 3XA 450 (204) WS11 T20P11F37CUEE 2 50 2 2 DS-3 115 819 3XA 703 (319) WS16 T20P11F50CUEE 75 2 2 DS-3 115 820 3XA 793 (360) WS16 T20P11F75CUEE 2 100 2 2 DS-3 115 821 3XA 1085 (493) WS13 T20P11F99CUEE 2 15 2 2 DS-3 80 818 3XA 407 (185) WS11 T20P11B15CUEE 25 2 2 DS-3 80 818 3XA 430 (195) WS11 T20P11B25CUEE 2 37.5 2 2 DS-3 80 819 3XA 685 (311) WS16 T20P11B37CUEE 50 2 2 DS-3 80 820 3XA 799 (363) WS16 T20P11B50CUEE 2 75 2 2 DS-3 80 821 3XA 1056 (479) WS13 T20P11B75CUEE 2 Full Capacity Taps 2 277 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DS-3 150 816 262C 275 (125) WS11 T27M11S15CUEE 2 25 2 at +2.5% 4 at –2.5% DS-3 150 818 262C 390 (177) WS11 T27M11S25CUEE 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 262C 440 (200) WS11 T27M11S37CUEE 2 50 2 at +2.5% 4 at –2.5% DS-3 150 819 262C 661 (300) WS16 T27M11S50CUEE 75 1 at +5% 2 at –5% DS-3 150 820 4 805 (365) WS16 T27R11S75CUEE 100 1 at +5% 2 at –5% DS-3 150 821 4 970 (440) WS13 T27R11S99CUEE 2 2 2 2 2 Full Capacity Taps Notes 1 Weights subject to change. 2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary. 3 480 volt primary only. 4 Contact your local Eaton sales office for these details. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 V2-T2-6 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 2 208 x 416 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 15 1 1 DS-3 150 816 3XF 275 (125) WS11 T18P11S15CUEE 25 1 1 DS-3 150 818 3XF 390 (177) WS11 T18P11S25CUEE 37.5 1 1 DS-3 150 818 3XF 440 (200) WS11 T18P11S37CUEE 50 1 1 DS-3 150 819 3XF 661 (300) WS16 T18P11S50CUEE 75 1 1 DS-3 150 820 3XF 805 (365) WS16 T18P11S75CUEE 100 1 1 DS-3 150 821 3XF 970 (440) WS13 T18P11S99CUEE 2 2 2 2 2 2 600 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DS-3 150 816 262B 290 (132) WS11 T60M11S15CUEE 25 2 at +2.5% 4 at –2.5% DS-3 150 818 262B 465 (211) WS11 T60M11S25CUEE 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 262B 495 (225) WS11 T60M11S37CUEE 50 2 at +2.5% 4 at –2.5% DS-3 150 819 262B 775 (352) WS16 T60M11S50CUEE 75 2 at +2.5% 4 at –2.5% DS-3 150 820 262B 900 (409) WS16 T60M11S75CUEE 100 2 at +2.5% 4 at –2.5% DS-3 150 821 262B 1195 (543) WS13 T60M11S99CUEE 2 2 2 2 2 Notes 1 1 at +5%, 2 at –5% at 208 volts primary; 2 at +2.5%, 4 at –2.5% at 416 volts primary. 2 Weights subject to change. 2 2 For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-7 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings 2 208 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DS-3 150 816 264A 275 (125) WS11 T29M11E15EE 2 25 2 at +2.5% 4 at –2.5% DS-3 150 818 264A 390 (177) WS11 T29M11E25EE 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 264A 440 (200) WS11 T29M11E37EE 2 50 2 at +2.5% 4 at –2.5% DS-3 150 819 264A 661 (300) WS16 T29M11E50EE 75 1 at +5% 2 at –5% DS-3 150 820 450A 805 (366) WS16 T29R11E75EE 2 100 1 at +5% 2 at –5% DS-3 150 821 450A 970 (440) WS13 T29R11E99EE Full Capacity Taps 2 240 x 480 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 2 DS-3 150 816 261A 246 (112) WS11 T20P11E15EE 2 25 2 2 DS-3 150 818 261A 359 (163) WS11 T20P11E25EE 37.5 2 2 DS-3 150 818 261A 374 (170) WS11 T20P11E37EE 2 50 2 2 DS-3 150 819 261A 555 (252) WS16 T20P11E50EE 75 2 2 DS-3 150 820 261A 740 (336) WS16 T20P11E75EE 2 100 2 2 DS-3 150 821 261A 841 (382) WS13 T20P11E99EE 2 167 2 at +2.5% 4 at –2.5% DS-3 150 814E 227A 1294 (587) WS13 T48M11E67EE 3 15 2 2 DS-3 115 816 261A 246 (112) WS11 T20P11F15EEES 2 25 2 2 DS-3 115 818 261A 373 (169) WS11 T20P11F25EEES 37.5 2 2 DS-3 115 818 261A 380 (173) WS11 T20P11F37EEES 2 50 2 2 DS-3 115 819 261A 590 (268) WS16 T20P11F50EEES 75 2 2 DS-3 115 820 261A 691 (314) WS16 T20P11F75EEES 2 100 2 2 DS-3 115 821 261A 844 (383) WS13 T20P11F99EEES 2 15 2 2 DS-3 80 818 261A 360 (163) WS11 T20P11B15EEES 25 2 2 DS-3 80 818 261A 370 (168) WS11 T20P11B25EEES 2 37.5 2 2 DS-3 80 819 261A 565 (257) WS16 T20P11B37EEES 50 2 2 DS-3 80 820 261A 680 (309) WS16 T20P11B50EEES 2 75 2 2 DS-3 80 821 261A 900 (409) WS13 T20P11B75EEES Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 Full Capacity Taps 2 277 Volts to 120/240 Volts 2 kVA 2 Full Capacity Taps FCAN FCBN 15 2 at +2.5% 4 at –2.5% DS-3 150 816 4 275 (125) WS11 T27M11E15EE 2 25 2 at +2.5% 4 at –2.5% DS-3 150 818 4 390 (177) WS11 T27M11E25EE 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 4 440 (200) WS11 T27M11E37EE 2 50 2 at +2.5% 4 at –2.5% DS-3 150 819 4 661 (300) WS16 T27M11E50EE 75 1 at +5% 2 at –5% DS-3 150 820 4 805 (366) WS16 T27R11E75EE 100 1 at +5% 2 at –5% DS-3 150 821 4 970 (440) WS13 T27R11E99EE 2 2 2 2 Notes 1 Weights subject to change. 2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary. 3 480 volt primary only. 4 Contact your local Eaton sales office for these details. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 V2-T2-8 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings 2 2 208 x 416 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 15 1 1 DS-3 150 816 243H 275 (125) WS11 T43P11E15EE 25 1 1 DS-3 150 818 243H 390 (177) WS11 T43P11E25EE 37.5 1 1 DS-3 150 818 243H 440 (200) WS11 T43P11E37EE 50 1 1 DS-3 150 819 243H 661 (300) WS16 T43P11E50EE 75 1 1 DS-3 150 820 3 805 (366) WS16 T43P11E75EE 100 1 1 DS-3 150 821 3 970 (440) WS13 T43P11E99EE 2 2 2 2 2 2 600 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DS-3 150 816 259A 275 (125) WS11 T60M11E15EE 25 2 at +2.5% 4 at –2.5% DS-3 150 818 259A 390 (177) WS11 T60M11E25EE 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 259A 440 (200) WS11 T60M11E37EE 50 2 at +2.5% 4 at –2.5% DS-3 150 819 259A 661 (300) WS16 T60M11E50EE 75 1 at +5% 2 at –5% DS-3 150 820 3 805 (366) WS16 T60R11E75EE 100 1 at +5% 2 at –5% DS-3 150 821 3 970 (440) WS13 T60R11E99EE 2 2 2 2 2 Notes 1 1 at +5%, 2 at –5% at 208 volts primary; 2 at +2.5%, 4 at –2.5% at 416 volts primary. 2 Weights subject to change. 3 Contact your local Eaton sales office for these details. 2 2 For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-9 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings 2 208 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DS-3 150 816 264A 270 (123) WS11 T29M11E15CUEE 2 25 2 at +2.5% 4 at –2.5% DS-3 150 818 264A 423 (192) WS11 T29M11E25CUEE 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 264A 437 (198) WS11 T29M11E37CUEE 2 2 Full Capacity Taps 50 2 at +2.5% 4 at –2.5% DS-3 150 819 264A 620 (281) WS16 T29M11E50CUEE 75 1 at +5% 2 at –5% DS-3 150 820 450A 810 (368) WS16 T29R11E75CUEE 100 1 at +5% 2 at –5% DS-3 150 821 450A 980 (445) WS13 T29R11E99CUEE 2 240 x 480 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 2 DS-3 150 816 261A 270 (123) WS11 T20P11E15CUEE 2 25 2 2 DS-3 150 818 261A 423 (192) WS11 T20P11E25CUEE 37.5 2 2 DS-3 150 818 261A 437 (198) WS11 T20P11E37CUEE 2 50 2 2 DS-3 150 819 261A 620 (281) WS16 T20P11E50CUEE 75 2 2 DS-3 150 820 261A 810 (368) WS16 T20P11E75CUEE 2 100 2 2 DS-3 150 821 261A 980 (445) WS13 T20P11E99CUEE 2 2 2 15 DS-3 115 816 261A 254 (115) WS11 T20P11F15CUEEES 25 2 2 DS-3 115 818 261A 453 (206) WS11 T20P11F25CUEEES 2 37.5 2 2 DS-3 115 818 261A 480 (218) WS11 T20P11F37CUEEES 50 2 2 DS-3 115 819 261A 718 (326) WS16 T20P11F50CUEEES 2 75 2 2 DS-3 115 820 261A 793 (360) WS16 T20P11F75CUEEES 100 2 2 DS-3 115 821 261A 1000 (454) WS13 T20P11F99CUEEES 15 2 2 DS-3 80 818 261A 240 (109) WS11 T20P11B15CUEEES 25 2 2 DS-3 80 818 261A 430 (195) WS11 T20P11B25CUEEES 37.5 2 2 DS-3 80 819 261A 700 (318) WS16 T20P11B37CUEEES 50 2 2 DS-3 80 820 261A 738 (335) WS16 T20P11B50CUEEES 75 2 2 DS-3 80 821 261A 960 (436) WS13 T20P11B75CUEEES Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 2 2 2 Full Capacity Taps 2 2 277 Volts to 120/240 Volts 2 kVA 2 15 2 at +2.5% 4 at –2.5% DS-3 150 816 3 270 (123) WS11 T27M11E15CUEE 25 2 at +2.5% 4 at –2.5% DS-3 150 818 3 423 (192) WS11 T27M11E25CUEE 2 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 3 437 (198) WS11 T27M11E37CUEE 50 2 at +2.5% 4 at –2.5% DS-3 150 819 3 620 (281) WS16 T27M11E50CUEE 2 75 1 at +5% 2 at –5% DS-3 150 820 3 810 (368) WS16 T27R11E75CUEE 100 1 at +5% 2 at –5% DS-3 150 821 3 980 (445) WS13 T27R11E99CUEE 2 2 2 Full Capacity Taps FCAN FCBN Notes 1 Weights subject to change. 2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary. 3 Contact your local Eaton sales office for these details. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 V2-T2-10 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings 2 2 208 x 416 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 15 1 1 DS-3 150 816 243H 270 (123) WS11 T43P11E15CUEE 25 1 1 DS-3 150 818 243H 423 (192) WS11 T43P11E25CUEE 37.5 1 1 DS-3 150 818 243H 437 (198) WS11 T43P11E37CUEE 50 1 1 DS-3 150 819 243H 620 (281) WS16 T43P11E50CUEE 75 1 1 DS-3 150 820 3 810 (368) WS16 T43P11E75CUEE 100 1 1 DS-3 150 821 3 980 (445) WS13 T43P11E99CUEE 2 2 2 2 2 2 600 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DS-3 150 816 259A 270 (123) WS11 T60M11E15CUEE 25 2 at +2.5% 4 at –2.5% DS-3 150 818 259A 423 (192) WS11 T60M11E25CUEE 37.5 2 at +2.5% 4 at –2.5% DS-3 150 818 259A 437 (198) WS11 T60M11E37CUEE 50 2 at +2.5% 4 at –2.5% DS-3 150 819 259A 620 (281) WS16 T60M11E50CUEE 75 1 at +5% 2 at –5% DS-3 150 820 3 810 (368) WS16 T60R11E75CUEE 100 1 at +5% 2 at –5% DS-3 150 821 3 980 (445) WS13 T60R11E99CUEE 2 2 2 2 2 Notes 1 1 at +5%, 2 at –5% at 208 volts primary; 2 at +2.5%, 4 at –2.5% at 416 volts primary. 2 Weights subject to change. 3 Contact your local Eaton sales office for these details. 2 For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-11 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 208 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280E 218 (99) WS38 V29M28T15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280E 299 (136) WS38 V29M28T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280E 376 (171) WS38 V29M28T45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280E 564 (256) WS39 V29M28T75EE 112.5 1 at +5% 2 at –5% DT-3 150 916A 324A 930 (422) WS19 V29R28T12EE 2 150 1 at +5% 2 at –5% DT-3 150 916A 324A 1013 (460) WS19 V29R28T49EE 225 1 at +5% 2 at –5% DT-3 150 918A 324A 1443 (655) WS34 V29R28T22EE 2 300 1 at +5% 2 at –5% DT-3 150 919E 289D 1697 (770) WS35 V29R28T33EE 2 500 1 at +5% 2 at –5% DT-3 150 920E 289D 2690 (1221) WS35 V29R28T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280E 240 (109) WS38 V29M28F15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280E 320 (145) WS38 V29M28F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280E 396 (180) WS38 V29M28F45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280E 607 (276) WS39 V29M28F75EE 2 112.5 1 at +5% 2 at –5% DT-3 115 916A 324A 960 (436) WS19 V29R28F12EE 150 1 at +5% 2 at –5% DT-3 115 916A 324A 1060 (481) WS19 V29R28F49EE 2 225 1 at +5% 2 at –5% DT-3 115 918A 324A 1500 (681) WS34 V29R28F22EE 300 1 at +5% 2 at –5% DT-3 115 919E 289D 1800 (817) WS35 V29R28F33EE 2 500 1 at +5% 2 at –5% DT-3 115 920E 289D 2900 (1317) WS35 V29R28F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280E 280 (127) WS38 V29M28B15EE 2 2 2 2 2 2 Full Capacity Taps 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280E 350 (159) WS38 V29M28B30EE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 280E 560 (254) WS39 V29M28B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280E 810 (368) WS19 V29M28B75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280E 950 (431) WS19 V29M28B12EE 150 1 at +5% 2 at –5% DT-3 80 918A 324A 1430 (649) WS34 V29R28B49EE 225 1 at +5% 2 at –5% DT-3 80 919E 289D 1750 (795) WS35 V29R28B22EE 300 1 at +5% 2 at –5% DT-3 80 920E 289D 2400 (1090) WS35 V29R28B33EE Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-12 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 2 208 Delta Volts to 480Y/277 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 342B 196 (89) WS38 V29M47T15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 342B 296 (134) WS38 V29M47T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 342B 385 (175) WS38 V29M47T45EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 342B 590 (268) WS39 V29M47T75EE 112.5 1 at +5% 2 at –5% DT-3 150 916A 351A 784 (356) WS19 V29R47T12EE 150 1 at +5% 2 at –5% DT-3 150 916A 351A 931 (423) WS19 V29R47T49EE 225 1 at +5% 2 at –5% DT-3 150 918A 333B 1550 (704) WS34 V29R47T22EE 300 1 at +5% 2 at –5% DT-3 150 919E 333B 2274 (1032) WS35 V29R47T33EE 500 1 at +5% 2 at –5% DT-3 150 919E 333B 2869 (1303) WS35 V29R47T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 342B 215 (98) WS38 V29M47F15EE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 342B 380 (173) WS38 V29M47F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 342B 400 (182) WS38 V29M47F45EE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 342B 585 (266) WS39 V29M47F75EE 112.5 1 at +5% 2 at –5% DT-3 115 916A 351A 800 (363) WS19 V29R47F12EE 150 1 at +5% 2 at –5% DT-3 115 916A 351A 950 (431) WS19 V29R47F49EE 225 1 at +5% 2 at –5% DT-3 115 918A 333B 1591 (722) WS34 V29R47F22EE 300 1 at +5% 2 at –5% DT-3 115 919E 333B 2320 (1053) WS35 V29R47F33EE 500 1 at +5% 2 at –5% DT-3 115 919E 333B 2950 (1339) WS35 V29R47F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 342B 300 (136) WS38 V29M47B15EE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 342B 390 (177) WS38 V29M47B30EE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 342B 550 (249) WS39 V29M47B45EE 75 1 at +5% 2 at –5% DT-3 80 916A 351A 757 (344) WS19 V29R47B75EE 112.5 1 at +5% 2 at –5% DT-3 80 916A 351A 930 (422) WS19 V29R47B12EE 150 1 at +5% 2 at –5% DT-3 80 918A 333B 1550 (704) WS34 V29R47B49EE 225 1 at +5% 2 at –5% DT-3 80 919E 333B 2275 (1033) WS35 V29R47B22EE 300 1 at +5% 2 at –5% DT-3 80 920E 333B 2870 (1303) WS35 V29R47B33EE 2 Catalog Number 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-13 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 240 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280C 206 (94) WS38 V24M28T15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280C 297 (135) WS38 V24M28T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280C 332 (151) WS38 V24M28T45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280C 562 (255) WS39 V24M28T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280C 760 (345) WS19 V24M28T12EE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280C 974 (442) WS19 V24M28T49EE 225 1 at +5% 2 at –5% DT-3 150 917 289A 1460 (663) WS34 V24R28T22EE V24R28T33EE Full Capacity Taps 2 300 1 at +5% 2 at –5% DT-3 150 918A 289A 1652 (750) WS34 2 500 1 at +5% 2 at –5% DT-3 150 919E 289A 2690 (1221) WS35 V24R28T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280C 240 (109) WS38 V24M28F15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280C 389 (177) WS38 V24M28F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280C 396 (180) WS38 V24M28F45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280C 593 (269) WS39 V24M28F75EE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280C 941 (427) WS19 V24M28F12EE 150 1 at +5% 2 at –5% DT-3 115 916A 280C 1060 (481) WS19 V24R28F49EE 2 225 1 at +5% 2 at –5% DT-3 115 917 289A 1500 (681) WS34 V24R28F22EE 300 1 at +5% 2 at –5% DT-3 115 918A 289A 1800 (817) WS34 V24R28F33EE 2 500 1 at +5% 2 at –5% DT-3 115 919E 289A 2900 (1317) WS35 V24R28F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280C 280 (127) WS38 V24M28B15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280C 350 (159) WS38 V24M28B30EE 2 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 280C 560 (254) WS39 V24M28B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280C 883 (401) WS19 V24M28B75EE 2 112.5 1 at +5% 2 at –5% DT-3 80 916A 280C 950 (431) WS19 V24R28B12EE 150 1 at +5% 2 at –5% DT-3 80 917 289A 1430 (649) WS34 V24R28B49EE 2 225 1 at +5% 2 at –5% DT-3 80 918A 289A 1750 (795) WS34 V24R28B22EE 300 1 at +5% 2 at –5% DT-3 80 919E 289A 2400 (1090) WS35 V24R28B33EE 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-14 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 2 240 Delta Volts to 480Y/277 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 342L 227 (103) WS38 V24M47T15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 342L 306 (139) WS38 V24M47T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 342L 380 (173) WS38 V24M47T45EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 342L 573 (260) WS39 V24M47T75EE 2 Catalog Number 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 342L 800 (363) WS19 V24M47T12EE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 342L 885 (402) WS19 V24M47T49EE 225 1 at +5% 2 at –5% DT-3 150 918A 333A 1612 (732) WS34 V24R47T22EE 300 1 at +5% 2 at –5% DT-3 150 919E 333A 1652 (750) WS35 V24R47T33EE 500 1 at +5% 2 at –5% DT-3 150 919E 333A 2695 (1224) WS35 V24R47T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 342L 240 (109) WS38 V24M47F15EE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 342L 389 (177) WS38 V24M47F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 342L 396 (180) WS38 V24M47F45EE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 342L 593 (269) WS39 V24M47F75EE 112.5 1 at +5% 2 at –5% DT-3 115 916A 342L 941 (427) WS19 V24R47F12EE 150 1 at +5% 2 at –5% DT-3 115 916A 342L 1060 (481) WS19 V24R47F49EE 225 1 at +5% 2 at –5% DT-3 115 918A 333A 1500 (681) WS34 V24R47F22EE 300 1 at +5% 2 at –5% DT-3 115 919E 333A 1800 (817) WS35 V24R47F33EE 500 1 at +5% 2 at –5% DT-3 115 919E 333A 2900 (1317) WS35 V24R47F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 342L 280 (127) WS38 V24M47B15EE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 342L 350 (159) WS38 V24M47B30EE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 342L 560 (254) WS39 V24M47B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 342L 883 (401) WS19 V24M47B75EE 112.5 1 at +5% 2 at –5% DT-3 80 916A 342L 950 (431) WS19 V24R47B12EE 150 1 at +5% 2 at –5% DT-3 80 918A 333A 1430 (649) WS34 V24R47B49EE 225 1 at +5% 2 at –5% DT-3 80 919E 333A 1750 (795) WS35 V24R47B22EE 300 1 at +5% 2 at –5% DT-3 80 919E 333A 2400 (1090) WS35 V24R47B33EE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-15 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 440 Delta Volts to 220Y/127 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280J 204 (93) WS38 V44M31T15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280J 291 (132) WS38 V44M31T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280J 351 (159) WS38 V44M31T45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280J 553 (251) WS39 V44M31T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280J 793 (360) WS19 V44M31T12EE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280J 913 (415) WS19 V44M31T49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 280J 1343 (610) WS34 V44M31T22EE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 918A 275F 1597 (725) WS34 V44M31T33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 275F 2590 (1176) WS35 V44M31T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280J 202 (92) WS38 V44M31F15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280J 311 (141) WS38 V44M31F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280J 418 (190) WS38 V44M31F45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280J 581 (264) WS39 V44M31F75EE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280J 829 (376) WS19 V44M31F12EE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 280J 996 (452) WS19 V44M31F49EE 2 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 280J 1569 (712) WS34 V44M31F22EE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 280J 1908 (866) WS37 V44M31F33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 275F 3117 (1415) WS35 V44M31F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280J 276 (125) WS38 V44M31B15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280J 350 (159) WS38 V44M31B30EE 2 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 280J 560 (254) WS39 V44M31B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280J 810 (368) WS19 V44M31B75EE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280J 944 (429) WS19 V44M31B12EE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 280J 1438 (653) WS34 V44M31B49EE 2 225 2 at +2.5% 4 at –2.5% DT-3 80 923 280J 1746 (793) WS37 V44M31B22EE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 275F 2400 (1090) WS35 V44M31B33EE 2 2 Full Capacity Taps Notes 1 Weights subject to change. Additional voltage combinations are available. Contact your local Eaton sales office for assistance if the voltage you require is not included in this catalog. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-16 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 2 480 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 204 (93) WS38 V48M28T15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 291 (132) WS38 V48M28T30EE 37.5 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 381 (173) WS38 V48M28T37EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 351 (159) WS38 V48M28T45EE 50 2 at +2.5% 4 at –2.5% DT-3 150 914F 280B 531 (241) WS39 V48M28T50EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280B 553 (251) WS39 V48M28T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280B 793 (360) WS19 V48M28T12EE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280B 913 (415) WS19 V48M28T49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 928 657B 1160 (527) WS41 V48M28T22EE 300 2 at +2.5% 4 at –2.5% DT-3 150 929 657B 1415 (642) WS42 V48M28T33EE 500 2 at +2.5% 2 at –2.5% DT-3 150 924 428B 2415 (1097) WS40 V48D28T55EE 750 2 at +2.5% 4 at –2.5% DT-3 150 920E 275A 3340 (1516) WS35 V48M28T77EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 202 (92) WS38 V48M28F15EE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 311 (141) WS38 V48M28F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 418 (190) WS38 V48M28F45EE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280B 581 (264) WS39 V48M28F75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280B 829 (376) WS19 V48M28F12EE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 280B 996 (452) WS19 V48M28F49EE 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 280B 1569 (712) WS34 V48M28F22EE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 280B 1908 (866) WS37 V48M28F33EE 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 275A 3117 (1415) WS35 V48M28F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280B 276 (125) WS38 V48M28B15EE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280B 350 (159) WS38 V48M28B30EE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 280B 560 (254) WS39 V48M28B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280B 810 (368) WS19 V48M28B75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280B 944 (429) WS19 V48M28B12EE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 280B 1438 (653) WS34 V48M28B49EE 225 2 at +2.5% 4 at –2.5% DT-3 80 923 280B 1746 (793) WS37 V48M28B22EE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 275A 2400 (1090) WS35 V48M28B33EE 500 2 at +2.5% 4 at –2.5% DT-3 80 920E 275A 3418 (1552) WS35 V48M28B55EE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. Additional voltage combinations are available. Contact your local Eaton sales office for assistance if the voltage you require is not included in this catalog. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-17 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 282B 206 (94) WS38 V48M22T15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 282B 291 (132) WS38 V48M22T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 282B 378 (172) WS38 V48M22T45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 282B 577 (262) WS39 V48M22T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 282B 790 (359) WS19 V48M22T12EE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 282B 930 (422) WS19 V48M22T49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 291A 1476 (670) WS34 V48M22T22EE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 923 291A 1898 (862) WS37 V48M22T33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 291A 2590 (1176) WS35 V48M22T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 282B 206 (94) WS38 V48M22F15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 282B 311 (141) WS38 V48M22F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 282B 418 (190) WS38 V48M22F45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 282B 581 (264) WS39 V48M22F75EE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 282B 829 (376) WS19 V48M22F12EE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 282B 1022 (464) WS19 V48M22F49EE 2 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 282B 1565 (711) WS34 V48M22F22EE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 282B 1795 (815) WS37 V48M22F33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 291A 3120 (1416) WS35 V48M22F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 282B 278 (126) WS38 V48M22B15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 282B 383 (174) WS38 V48M22B30EE 2 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 282B 560 (254) WS39 V48M22B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 282B 810 (368) WS19 V48M22B75EE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 282B 959 (435) WS19 V48M22B12EE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 282B 1287 (584) WS34 V48M22B49EE 2 225 2 at +2.5% 4 at –2.5% DT-3 80 923 282B 1746 (793) WS37 V48M22B22EE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 291A 2400 (1090) WS35 V48M22B33EE 2 2 2 Full Capacity Taps Notes 1 Lighting tap limited to 5% of nameplate full load capacity. 2 Weights subject to change. Additional voltage combinations are available. Contact your local Eaton sales office for assistance if the voltage you require is not included in this catalog. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-18 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 2 480 Delta Volts to 480Y/277 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 206 (94) WS38 V48M47T15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 281 (128) WS38 V48M47T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 380 (173) WS38 V48M47T45EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280B 565 (257) WS39 V48M47T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280B 783 (355) WS19 V48M47T12EE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280B 945 (429) WS19 V48M47T49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 280B 1413 (642) WS34 V48M47T22EE 300 2 at +2.5% 4 at –2.5% DT-3 150 918A 275A 1910 (867) WS34 V48M47T33EE 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 275A 2673 (1214) WS35 V48M47T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 240 (109) WS38 V48M47F15EE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 316 (143) WS38 V48M47F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 384 (174) WS38 V48M47F45EE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280B 670 (304) WS39 V48M47F75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280B 853 (387) WS19 V48M47F12EE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 280B 982 (446) WS19 V48M47F49EE 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 280B 1559 (708) WS34 V48M47F22EE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 280B 1795 (815) WS37 V48M47F33EE 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 275A 3120 (1416) WS35 V48M47F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280B 271 (123) WS38 V48M47B15EE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280B 360 (163) WS38 V48M47B30EE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 280B 563 (256) WS39 V48M47B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280B 773 (351) WS19 V48M47B75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280B 954 (433) WS19 V48M47B12EE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 280B 1330 (604) WS34 V48M47B49EE 225 2 at +2.5% 4 at –2.5% DT-3 80 923 280B 1827 (829) WS37 V48M47B22EE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 275A 2540 (1153) WS35 V48M47B33EE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. Additional voltage combinations are available. Contact your local Eaton sales office for assistance if the voltage you require is not included in this catalog. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-19 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 600 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 231 (105) WS38 V60M28T15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 309 (140) WS38 V60M28T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 375 (170) WS38 V60M28T45EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280A 572 (260) WS39 V60M28T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280A 801 (364) WS19 V60M28T12EE 2 2 Full Capacity Taps Catalog Number 150 2 at +2.5% 4 at –2.5% DT-3 150 917 280A 1013 (460) WS34 V60M28T49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 918A 280A 1523 (691) WS34 V60M28T22EE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 919E 280A 1697 (770) WS35 V60M28T33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 920E 280A 2690 (1221) WS35 V60M28T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 240 (109) WS38 V60M28F15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 320 (145) WS38 V60M28F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 396 (180) WS38 V60M28F45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280A 607 (276) WS39 V60M28F75EE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280A 960 (436) WS19 V60M28F12EE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 280A 1060 (481) WS19 V60M28F49EE 2 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 280A 1500 (681) WS34 V60M28F22EE 300 2 at +2.5% 4 at –2.5% DT-3 115 919E 280A 1800 (817) WS35 V60M28F33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 280A 2900 (1317) WS35 V60M28F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280A 280 (127) WS38 V60M28B15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280A 350 (159) WS38 V60M28B30EE 2 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 280A 560 (254) WS39 V60M28B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280A 810 (368) WS19 V60M28B75EE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280A 950 (431) WS19 V60M28B12EE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 280A 1430 (649) WS34 V60M28B49EE 2 225 2 at +2.5% 4 at –2.5% DT-3 80 919E 280A 1750 (795) WS35 V60M28B22EE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 280A 2400 (1090) WS35 V60M28B33EE 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-20 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 2 600 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1 Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 282A 245 (111) WS38 V60M22T15EE 282A 313 (142) WS38 V60M22T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 75 2 at +2.5% 4 at –2.5% DT-3 150 912D 282A 403 (183) WS38 V60M22T45EE 914F 282A 577 (262) WS39 V60M22T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 282A 790 (359) WS19 V60M22T12EE 150 2 at +2.5% 4 at –2.5% DT-3 150 917 282A 1001 (454) WS34 V60M22T49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 918A 282A 1476 (670) WS34 V60M22T22EE 300 2 at +2.5% 4 at –2.5% DT-3 150 919E 282A 1898 (862) WS35 V60M22T33EE 500 2 at +2.5% 4 at –2.5% DT-3 150 920E 282A 2590 (1176) WS35 V60M22T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 282A 206 (94) WS38 V60M22F15EE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 282A 311 (141) WS38 V60M22F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 282A 418 (190) WS38 V60M22F45EE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 282A 581 (264) WS39 V60M22F75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 282A 829 (376) WS19 V60M22F12EE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 282A 1022 (464) WS19 V60M22F49EE 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 282A 1565 (711) WS34 V60M22F22EE 300 2 at +2.5% 4 at –2.5% DT-3 115 919E 282A 1795 (815) WS35 V60M22F33EE 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 282A 3120 (1416) WS35 V60M22F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 282A 278 (126) WS38 V60M22B15EE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 282A 383 (174) WS38 V60M22B30EE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 282A 560 (254) WS39 V60M22B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 282A 810 (368) WS19 V60M22B75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 282A 959 (435) WS19 V60M22B12EE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 282A 1287 (584) WS34 V60M22B49EE 225 2 at +2.5% 4 at –2.5% DT-3 80 919E 282A 1746 (793) WS35 V60M22B22EE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 282A 2400 (1090) WS35 V60M22B33EE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Lighting tap limited to 5% of nameplate full load capacity. 2 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-21 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 600 Delta Volts to 480Y/277 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 206 (94) WS38 V60M47T15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 291 (132) WS38 V60M47T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 382 (173) WS38 V60M47T45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280A 578 (262) WS39 V60M47T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280A 811 (368) WS19 V60M47T12EE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280A 934 (424) WS19 V60M47T49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 280A 1569 (712) WS34 V60M47T22EE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 923 280A 1997 (907) WS37 V60M47T33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 275C 2641 (1199) WS35 V60M47T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 206 (94) WS38 V60M47F15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 311 (141) WS38 V60M47F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 418 (190) WS38 V60M47F45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280A 581 (264) WS39 V60M47F75EE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280A 829 (376) WS19 V60M47F12EE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 280A 1022 (464) WS19 V60M47F49EE 2 225 2 at +2.5% 4 at –2.5% DT-3 115 917 280A 1565 (7101) WS34 V60M47F22EE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 280A 1795 (815) WS37 V60M47F33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 275C 3120 (1416) WS35 V60M47F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280A 278 (126) WS38 V60M47B15EE 2 2 2 2 2 2 Full Capacity Taps 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280A 383 (174) WS38 V60M47B30EE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 280A 560 (254) WS39 V60M47B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280A 810 (368) WS19 V60M47B75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280A 959 (435) WS19 V60M47B12EE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 280A 1287 (584) WS34 V60M47B49EE 225 2 at +2.5% 4 at –2.5% DT-3 80 923 280A 1746 (793) WS37 V60M47B22EE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 275C 2650 (1203) WS35 V60M47B33EE Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-22 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 2 208 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D — 236 (107) WS38 V29M28T15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D — 351 (159) WS38 V29M28T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D — 453 (206) WS38 V29M28T45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F — 687 (312) WS39 V29M28T75CUEE 112.5 1 at +5% 2 at –5% DT-3 150 916A — 930 (422) WS19 V29R28T12CUEE 150 1 at +5% 2 at –5% DT-3 150 916A — 1242 (564) WS19 V29R28T49CUEE 225 1 at +5% 2 at –5% DT-3 150 917 — 1763 (800) WS34 V29R28T22CUEE 300 1 at +5% 2 at –5% DT-3 150 918A — 2300 (1044) WS34 V29R28T33CUEE 500 1 at +5% 2 at –5% DT-3 150 919E — 3590 (1630) WS35 V29R28T55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D — 265 (120) WS38 V29M28F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D — 475 (215) WS38 V29M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D — 475 (216) WS38 V29M28F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F — 700 (318) WS39 V29M28F75CUEE 112.5 1 at +5% 2 at –5% DT-3 115 916A — 935 (424) WS19 V29R28F12CUEE 150 1 at +5% 2 at –5% DT-3 115 916A — 1274 (578) WS19 V29R28F49CUEE 225 1 at +5% 2 at –5% DT-3 115 917 — 1743 (791) WS34 V29R28F22CUEE 300 1 at +5% 2 at –5% DT-3 115 919E — 2350 (1067) WS35 V29R28F33CUEE 500 1 at +5% 2 at –5% DT-3 115 920E — 3690 (1675) WS35 V29R28F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D — 381 (173) WS38 V29M28B15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D — 420 (191) WS38 V29M28B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 912D — 510 (232) WS38 V29M28B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 914F — 940 (427) WS39 V29M28B75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A — 1300 (590) WS19 V29M28B12CUEE 150 1 at +5% 2 at –5% DT-3 80 918A — 1800 (817) WS34 V29R28B49CUEE 225 1 at +5% 2 at –5% DT-3 80 919E — 2400 (1090) WS35 V29R28B22CUEE 300 1 at +5% 2 at –5% DT-3 80 920E — 3800 (1725) WS35 V29R28B33CUEE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-23 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 208 Delta Volts to 480Y/277 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 342B 236 (107) WS38 V29M47T15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 342B 351 (159) WS38 V29M47T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 342B 453 (206) WS38 V29M47T45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 342B 687 (312) WS39 V29M47T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 351A 930 (422) WS19 V29R47T12CUEE 2 150 1 at +5% 2 at –5% DT-3 150 916A 351A 1242 (564) WS19 V29R47T49CUEE 225 1 at +5% 2 at –5% DT-3 150 917 333B 1763 (800) WS34 V29R47T22CUEE 2 300 1 at +5% 2 at –5% DT-3 150 918A 333B 2300 (1044 WS34 V29R47T33CUEE 2 500 1 at +5% 2 at –5% DT-3 150 919E 333B 3590 (1630) WS35 V29R47T55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 342B 265 (120) WS38 V29M47F15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 342B 474.6 (215) WS38 V29M47F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 342B 475 (216) WS38 V29M47F45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 342B 700 (318) WS39 V29M47F75CUEE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 342B 935 (424) WS19 V29M47F12CUEE 150 1 at +5% 2 at –5% DT-3 115 916A 351A 1274 (578) WS19 V29R47F49CUEE 2 225 1 at +5% 2 at –5% DT-3 115 917 333B 1743 (791) WS34 V29R47F22CUEE 300 1 at +5% 2 at –5% DT-3 115 919E 333B 2350 (1067) WS35 V29R47F33CUEE 2 500 1 at +5% 2 at –5% DT-3 115 920E 333B 3690 (1675) WS35 V29R47F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 342B 381 (173) WS38 V29M47B15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 342B 420 (191) WS38 V29M47B30CUEE 2 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 342B 510 (232) WS38 V29M47B45CUEE 75 1 at +5% 2 at –5% DT-3 80 914F 342B 940 (427) WS39 V29R47B75CUEE 2 112.5 1 at +5% 2 at –5% DT-3 80 916A 342B 1300 (590) WS19 V29R47B12CUEE 150 1 at +5% 2 at –5% DT-3 80 918A 342B 1800 (817) WS34 V29R47B49CUEE 2 225 1 at +5% 2 at –5% DT-3 80 919E 333B 2400 (1090) WS35 V29R47B22CUEE 300 1 at +5% 2 at –5% DT-3 80 920E 333B 3800 (1725) WS35 V29R47B33CUEE 2 2 Full Capacity Taps Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-24 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 2 240 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280C 246 (112) — V24M28T15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280C 331 (150) — V24M28T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280C 289 (131) — V24M28T45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280C 664 (301) — V24M28T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280C — — V24M28T12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280C 1130 (513) — V24M28T49CUEE 225 1 at +5% 2 at –5% DT-3 150 — — — — V24R28T22CUEE 300 1 at +5% 2 at –5% DT-3 150 — — — — V24R28T33CUEE 500 1 at +5% 2 at –5% DT-3 150 — — — — V24R28T55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D — — — V24M28F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D — — — V24M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 — — — — V24M28F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280C 680 (308) — V24M28F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 — — — — V24M28F12CUEE 150 1 at +5% 2 at –5% DT-3 115 — — — — V24R28F49CUEE 225 1 at +5% 2 at –5% DT-3 115 — — — — V24R28F22CUEE 300 1 at +5% 2 at –5% DT-3 115 — — — — V24R28F33CUEE 500 1 at +5% 2 at –5% DT-3 115 — — — — V24R28F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280C 346 (157) — V24M28B15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 80 — — — — V24M28B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 — — — — V24M28B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 — — — — V24M28B75CUEE 112.5 1 at +5% 2 at –5% DT-3 80 — — — — V24R28B12CUEE 150 1 at +5% 2 at –5% DT-3 80 917 289A 1774 (805) — V24R28B49CUEE 225 1 at +5% 2 at –5% DT-3 80 — — — — V24R28B22CUEE 300 1 at +5% 2 at –5% DT-3 80 — — — — V24R28B33CUEE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-25 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 240 Delta Volts to 480Y/277 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 342L 341 (155) — V24M47T15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 342L 436 (198) — V24M47T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 914F 342L 685 (311) — V24M47T45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 342L — — V24M47T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 — — — — V24M47T12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 — — — — V24M47T49CUEE 225 1 at +5% 2 at –5% DT-3 150 — — — — V24R47T22CUEE 2 300 1 at +5% 2 at –5% DT-3 150 — — — — V24R47T33CUEE 2 500 1 at +5% 2 at –5% DT-3 150 — — — — V24R47T55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D — — — V24M47F15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 — — — — V24M47F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 — — — — V24M47F45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 — — — — V24M47F75CUEE 2 112.5 1 at +5% 2 at –5% DT-3 115 916A 351C 1009 (458) — V24R47F12CUEE 150 1 at +5% 2 at –5% DT-3 115 — — — — V24R47F49CUEE 2 225 1 at +5% 2 at –5% DT-3 115 — — — — V24R47F22CUEE 300 1 at +5% 2 at –5% DT-3 115 — — — — V24R47F33CUEE 2 500 1 at +5% 2 at –5% DT-3 115 — — — — V24R47F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D — — — V24M47B15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 80 — — — — V24M47B30CUEE 2 45 2 at +2.5% 4 at –2.5% DT-3 80 — — — — V24M47B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 — — — — V24M47B75CUEE 2 112.5 1 at +5% 2 at –5% DT-3 80 — — — — V24R47B12CUEE 150 1 at +5% 2 at –5% DT-3 80 — — — — V24R47B49CUEE 2 225 1 at +5% 2 at –5% DT-3 80 — — — — V24R47B22CUEE 300 1 at +5% 2 at –5% DT-3 80 — — — — V24R47B33CUEE 2 2 Full Capacity Taps Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-26 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 2 440 Delta Volts to 220Y/127 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280J 250 (114) WS38 V44M31T15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280J 350 (159) WS38 V44M31T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280J 416 (189) WS38 V44M31T45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280J 643 (292) WS39 V44M31T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280J 876 (398) WS19 V44M31T12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280J 1064 (483) WS19 V44M31T49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 280J 1545 (701) WS34 V44M31T22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 150 923 275F 2050 (931) WS37 V44M31T33CUEE 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 275F 3681 (1671) WS35 V44M31T55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280J 256 (116) WS38 V44M31F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280J 337 (153) WS38 V44M31F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280J 446 (202) WS38 V44M31F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280J 662 (301) WS39 V44M31F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280J 914 (415) WS19 V44M31F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 280J 1132 (514) WS19 V44M31F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 115 917 280J 2036 (924) WS34 V44M31F22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 275F 2325 (1056) WS37 V44M31F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 275F 3681 (1671) WS35 V44M31F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280J 349 (158) WS38 V44M31B15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280J 410 (186) WS38 V44M31B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 280J 504 (229) WS38 V44M31B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280J 818 (371) WS19 V44M31B75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280J 1065 (484) WS19 V44M31B12CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 917 280J 1410 (640) WS34 V44M31B49CUEE 22 2 at +2.5% 4 at –2.5% DT-3 80 923 280J 2030 (922) WS37 V44M31B22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 275F 3041 (1381) WS35 V44M31B33CUEE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-27 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 480 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 250 (114) WS38 V48M28T15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 350 (159) WS38 V48M28T30CUEE 37.5 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 415 (188) WS38 V48M28T37CUEE 2 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 416 (189) WS38 V48M28T45CUEE 50 2 at +2.5% 4 at –2.5% DT-3 150 914F 280B 647 (294) WS39 V48M28T50CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280B 643 (292) WS39 V48M28T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280B 876 (398) WS19 V48M28T12CUEE Full Capacity Taps 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280B 1064 (483) WS19 V48M28T49CUEE 2 225 2 at +2.5% 4 at –2.5% DT-3 150 928 657B 1371 (622) WS41 V48M28T22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 150 929 657B 1622 (736) WS42 V48M28T33CUEE 2 500 2 at +2.5% 2 at –2.5% DT-3 150 924 428B 3681 (1671) WS40 V48D28T55CUEE 750 2 at +2.5% 4 at –2.5% DT-3 150 920E 275A 4891 (2221) WS35 V48M28T77CUEE 2 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 256 (116) WS38 V48M28F15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 337 (153) WS38 V48M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 446 (202) WS38 V48M28F45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280B 662 (301) WS39 V48M28F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280B 914 (415) WS19 V48M28F12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 280B 1132 (514) WS19 V48M28F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 115 917 275A 2036 (924) WS34 V48M28F22CUEE 2 300 2 at +2.5% 4 at –2.5% DT-3 115 923 275A 2325 (1056) WS37 V48M28F33CUEE 2 500 2 at +2.5% 4 at –2.5% DT-3 115 919 275A 3681 (1671) WS35 V48M28F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280B 349 (158) WS38 V48M28B15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280B 410 (186) WS38 V48M28B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 280B 504 (229) WS38 V48M28B45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280B 818 (371) WS19 V48M28B75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280B 1065 (484) WS19 V48M28B12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3 80 917 280B 1410 (640) WS34 V48M28B49CUEE 2 225 2 at +2.5% 4 at –2.5% DT-3 80 923 275A 2030 (922) WS37 V48M28B22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 275A 3041 (1381) WS35 V48M28B33CUEE 500 2 at +2.5% 4 at –2.5% DT-3 80 920E 275A 4696 (2132) WS35 V48M28B55CUEE 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 V2-T2-28 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 2 480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1 Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 282B 253 (115) WS38 V48M22T15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 282B 352 (160) WS38 V48M22T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 282B 415 (188) WS38 V48M22T45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 282B 703 (319) WS39 V48M22T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 282B 935 (424) WS19 V48M22T12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 282B 1134 (515) WS19 V48M22T49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 282B 1955 (888) WS34 V48M22T22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 150 923 282B 2450 (1112) WS37 V48M22T33CUEE 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 291A 3547 (1610) WS35 V48M22T55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 282B 248 (113) WS38 V48M22F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 282B 410 (186) WS38 V48M22F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 282B 445 (202) WS38 V48M22F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 282B 750 (341) WS39 V48M22F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 282B 963 (437) WS19 V48M22F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 282B 1236 (561) WS19 V48M22F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 115 917 282B 2100 (953) WS34 V48M22F22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 282B 2600 (1180) WS37 V48M22F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 291A 3700 (1680) WS35 V48M22F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 282B 301 (137) WS38 V48M22B15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 282B 460 (209) WS38 V48M22B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 282B 505 (229) WS38 V48M22B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 282B 835 (379) WS19 V48M22B75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 282B 1050 (477) WS19 V48M22B12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 282B 2250 (1022) WS34 V48M22B49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 80 923 291A 2900 (1317) WS37 V48M22B22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 291A 4000 (1816) WS35 V48M22B33CUEE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Lighting tap limited to 5% of nameplate full load capacity. 2 Weight subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-29 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 480 Delta Volts to 480Y/277 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 257 (117) WS38 V48M47T15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 330 (150) WS38 V48M47T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280B 430 (195) WS38 V48M47T45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280B 675 (306) WS39 V48M47T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280B 900 (409) WS19 V48M47T12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280B 1126 (511) WS19 V48M47T49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 280B 2038 (925) WS34 V48M47T22CUEE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 923 280B 2550 (1158) WS37 V48M47T33CUEE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 275A 3412 (1549) WS35 V48M47T55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 258 (117) WS38 V48M47F15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 401 (182) WS38 V48M47F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280B 455 (207) WS38 V48M47F45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280B 678 (308) WS39 V48M47F75CUEE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280B 676 (307) WS19 V48M47F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 280B 1249 (567) WS19 V48M47F49CUEE 2 225 2 at +2.5% 4 at –2.5% DT-3 115 917 280B 2107 (957) WS34 V48M47F22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 280B 2418 (1098) WS37 V48M47F33CUEE 2 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 275A 3800 (1725) WS35 V48M47F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280B 369 (168) WS38 V48M47B15CUEE 2 2 Full Capacity Taps 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280B 423 (192) WS38 V48M47B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 280B 552 (251) WS38 V48M47B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280B 920 (418) WS19 V48M47B75CUEE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280B 1100 (499) WS19 V48M47B12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 280B 1702 (773) WS34 V48M47B49CUEE 2 225 2 at +2.5% 4 at –2.5% DT-3 80 923 280B 2313 (1050) WS37 V48M47B22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 275A 3100 (1407) WS35 V48M47B33CUEE 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-30 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 2 600 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 263 (119) WS38 V60M28T15CUEE 280A 368 (167) WS38 V60M28T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 75 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 437 (198) WS38 V60M28T45CUEE 914F 280A 675 (307) WS39 V60M28T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280A 920 (418) WS19 V60M28T12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280A 1117 (507) WS19 V60M28T49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 280A 1622 (737) WS34 V60M28T22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 150 923 280A 2153 (977) WS37 V60M28T33CUEE 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 280A 3865 (1755) WS35 V60M28T55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 269 (122) WS38 V60M28F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 354 (161) WS38 V60M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 468 (213) WS38 V60M28F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280A 695 (316) WS39 V60M28F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280A 960 (436) WS19 V60M28F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 280A 1189 (540) WS19 V60M28F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 115 917 280A 2138 (971) WS34 V60M28F22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 280A 2441 (1108) WS37 V60M28F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 280A 3865 (1755) WS35 V60M28F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280A 367 (166) WS38 V60M28B15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280A 431 (195) WS38 V60M28B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 280A 529 (240) WS38 V60M28B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280A 859 (390) WS19 V60M28B75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280A 1118 (508) WS19 V60M28B12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 280A 1481 (672) WS34 V60M28B49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 80 923 280A 2132 (968) WS37 V60M28B22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 280A 3193 (1450) WS35 V60M28B33CUEE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-31 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 600 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 282B 263 (119) WS38 V60M22T15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 282B 368 (167) WS38 V60M22T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 282B 437 (198) WS38 V60M22T45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 282B 675 (307) WS39 V60M22T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 282B 920 (418) WS19 V60M22T12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 282B 1117 (507) WS19 V60M22T49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 282B 1622 (737) WS34 V60M22T22CUEE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 923 282B 2153 (977) WS37 V60M22T33CUEE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 282B 3865 (1755) WS35 V60M22T55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 282B 269 (122) WS38 V60M22F15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 282B 354 (161) WS38 V60M22F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 282B 468 (213) WS38 V60M22F45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 282B 695 (316) WS39 V60M22F75CUEE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 282B 960 (436) WS19 V60M22F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 282B 1189 (540) WS19 V60M22F49CUEE 2 225 2 at +2.5% 4 at –2.5% DT-3 115 917 282B 2138 (971) WS34 V60M22F22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 282B 2441 (1108) WS37 V60M22F33CUEE 2 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 282B 3865 (1755) WS35 V60M22F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 282B 367 (166) WS38 V60M22B15CUEE 2 2 2 2 2 2 2 Full Capacity Taps 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 282B 431 (195) WS38 V60M22B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 282B 529 (240) WS38 V60M22B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 282B 859 (390) WS19 V60M22B75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 282B 1119 (508) WS19 V60M22B12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 282B 1481 (672) WS34 V60M22B49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 80 923 282B 2132 (968) WS37 V60M22B22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 282B 3193 (1450) WS35 V60M22B33CUEE Notes 1 Lighting tap limited to 5% of nameplate full load capacity. 2 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-32 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 2 600 Delta Volts to 480Y/277 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 283 (128) WS38 V60M47T15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 363 (165) WS38 V60M47T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 280A 473 (215) WS38 V60M47T45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 280A 743 (337) WS39 V60M47T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 280A 990 (449) WS19 V60M47T12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 280A 1239 (562) WS19 V60M47T49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 280A 2242 (1018) WS34 V60M47T22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 150 923 280A 2805 (1273) WS37 V60M47T33CUEE 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 275C 3753 (1704) WS35 V60M47T55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 284 (129) WS38 V60M47F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 441 (200) WS38 V60M47F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 280A 501 (227) WS38 V60M47F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 280A 746 (339) WS39 V60M47F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 280A 744 (338) WS19 V60M47F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 280A 1374 (624) WS19 V60M47F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 115 917 280A 2318 (1052) WS34 V60M47F22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 280A 2660 (1208) WS37 V60M47F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 275C 4180 (1898) WS35 V60M47F55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 280A 406 (184) WS38 V60M47B15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 280A 465 (211) WS38 V60M47B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 280A 607 (276) WS38 V60M47B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 280A 1012 (459) WS19 V60M47B75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 280A 1210 (549) WS19 V60M47B12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 280A 1872 (850) WS34 V60M47B49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 80 923 280A 2544 (1155) WS37 V60M47B22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 275C 3410 (1548) WS35 V60M47B33CUEE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-33 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings 2 208 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283A 220 (100) WS38 V29M28E15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283A 289 (131) WS38 V29M28E30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283A 365 (166) WS38 V29M28E45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283A 570 (259) WS39 V29M28E75EE 112.5 1 at +5% 2 at –5% DT-3 150 916A 287A 930 (422) WS19 V29R28E12EE 2 150 1 at +5% 2 at –5% DT-3 150 916A 287A 1013 (460) WS19 V29R28E49EE 225 1 at +5% 2 at –5% DT-3 150 918A 287A 1639 (744) WS34 V29R28E22EE 2 Full Capacity Taps 300 1 at +5% 2 at –5% DT-3 150 919E 287A 1697 (770) WS35 V29R28E33EE 500 1 at +5% 2 at –5% DT-3 150 920E 287A 2690 (1221) WS35 V29R28E55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283A 240 (109) WS38 V29M28F15EEES 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283A 365 (166) WS38 V29M28F30EEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283A 401 (182) WS38 V29M28F45EEES 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283A 606 (275) WS39 V29M28F75EEES 2 112.5 1 at +5% 2 at –5% DT-3 115 916A 287A 960 (436) WS19 V29R28F12EEES 150 1 at +5% 2 at –5% DT-3 115 916A 287A 1060 (481) WS19 V29R28F49EEES 225 1 at +5% 2 at –5% DT-3 115 918A 287A 1500 (681) WS34 V29R28F22EEES V29R28F33EEES 2 2 2 2 2 2 2 2 2 300 1 at +5% 2 at –5% DT-3 115 919E 287A 1800 (817) WS35 500 1 at +5% 2 at –5% DT-3 115 920E 287A 2900 (1317) WS35 V29R28F55EEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283A 280 (127) WS38 V29M28B15EEES 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283A 370 (168) WS38 V29M28B30EEES 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283A 563 (256) WS39 V29M28B45EEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283A 965 (438) WS19 V29M28B75EEES 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 283A 950 (431) WS19 V29M28B12EEES 150 1 at +5% 2 at –5% DT-3 80 918A 287A 1430 (649) WS34 V29R28B49EEES 225 1 at +5% 2 at –5% DT-3 80 919E 287A 1750 (795) WS35 V29R28B22EEES 300 1 at +5% 2 at –5% DT-3 80 920E 287A 2400 (1090) WS35 V29R28B33EEES Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-34 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings 2 2 208 Delta Volts to 480Y/277 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 345A 196 (89) WS38 V29M47E15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 345A 296 (134) WS38 V29M47E30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 345A 410 (186) WS38 V29M47E45EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 345A 590 (268) WS39 V29M47E75EE 112.5 1 at +5% 2 at –5% DT-3 150 916A 315A 784 (356) WS19 V29R47E12EE 150 1 at +5% 2 at –5% DT-3 150 916A 315A 931 (423) WS19 V29R47E49EE 225 1 at +5% 2 at –5% DT-3 150 918A 315A 1550 (704) WS34 V29R47E22EE 300 1 at +5% 2 at –5% DT-3 150 919E 315A 2274 (1032) WS35 V29R47E33EE 500 1 at +5% 2 at –5% DT-3 150 919E 315A 2869 (1303) WS35 V29R47E55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 345A 215 (98) WS38 V29M47F15EEES 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 345A 380 (173) WS38 V29M47F30EEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 345A 400 (182) WS38 V29M47F45EEES 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 345A 585 (266) WS39 V29M47F75EEES 112.5 1 at +5% 2 at –5% DT-3 115 916A 315A 800 (363) WS19 V29R47F12EEES 150 1 at +5% 2 at –5% DT-3 115 916A 315A 950 (431) WS19 V29R47F49EEES 225 1 at +5% 2 at –5% DT-3 115 918A 315A 1591 (722) WS34 V29R47F22EEES 300 1 at +5% 2 at –5% DT-3 115 919E 315A 2320 (1053) WS35 V29R47F33EEES 500 1 at +5% 2 at –5% DT-3 115 919E 315A 2950 (1339) WS35 V29R47F55EEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 345A 300 (136) WS38 V29M47B15EEES 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 345A 390 (177) WS38 V29M47B30EEES 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 345A 550 (250) WS39 V29M47B45EEES 75 1 at +5% 2 at –5% DT-3 80 916A 315A 757 (344) WS19 V29R47B75EEES 112.5 1 at +5% 2 at –5% DT-3 80 916A 315A 930 (422) WS19 V29R47B12EEES 150 1 at +5% 2 at –5% DT-3 80 918A 315A 1550 (704) WS34 V29R47B49EEES 225 1 at +5% 2 at –5% DT-3 80 919E 315A 2275 (1033) WS35 V29R47B22EEES 300 1 at +5% 2 at –5% DT-3 80 920E 315A 2870 (1303) WS35 V29R47B33EEES 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-35 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings 2 240 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283G 206 (94) WS38 V24M28E15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283G 297 (135) WS38 V24M28E30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283G 332 (151) WS38 V24M28E45EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283G 562 (255) WS39 V24M28E75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283G 760 (345) WS19 V24M28E12EE 2 2 2 Full Capacity Taps 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 283G 974 (442) WS19 V24M28E49EE 225 1 at +5% 2 at –5% DT-3 150 917 287B 1460 (663) WS34 V24R28E22EE 300 1 at +5% 2 at –5% DT-3 150 918A 287B 1652 (750) WS34 V24R28E33EE 500 1 at +5% 2 at –5% DT-3 150 919E 287B 2690 (1221) WS35 V24R28E55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283G 240 (109) WS38 V24M28F15EEES 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283G 389 (177) WS38 V24M28F30EEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283G 396 (180) WS38 V24M28F45EEES 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283G 593 (269) WS39 V24M28F75EEES 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283G 941 (427) WS19 V24M28F12EEES 150 1 at +5% 2 at –5% DT-3 115 916A 287B 1060 (481) WS19 V24R28F49EEES 2 225 1 at +5% 2 at –5% DT-3 115 917 287B 1500 (681) WS34 V24R28F22EEES 300 1 at +5% 2 at –5% DT-3 115 918A 287B 1800 (817) WS34 V24R28F33EEES 2 500 1 at +5% 2 at –5% DT-3 115 919E 287B 2900 (1317) WS35 V24R28F55EEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283G 280 (127) WS38 V24M28B15EEES 2 2 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283G 350 (159) WS38 V24M28B30EEES 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283G 560 (254) WS39 V24M28B45EEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283G 883 (401) WS19 V24M28B75EEES 2 112.5 1 at +5% 2 at –5% DT-3 80 916A 287B 950 (431) WS19 V24R28B12EEES 150 1 at +5% 2 at –5% DT-3 80 917 287B 1430 (649) WS34 V24R28B49EEES 2 225 1 at +5% 2 at –5% DT-3 80 918A 287B 1750 (795) WS34 V24R28B22EEES 300 1 at +5% 2 at –5% DT-3 80 919E 287B 2400 (1090) WS35 V24R28B33EEES 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-36 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings 2 2 240 Delta Volts to 480Y/277 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 345C 227 (103) WS38 V24M47E15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 345C 312 (142) WS38 V24M47E30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 345C 380 (173) WS38 V24M47E45EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 345C 573 (260) WS39 V24M47E75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 345C 800 (363) WS19 V24M47E12EE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 345C 885 (402) WS19 V24M47E49EE 225 1 at +5% 2 at –5% DT-3 150 918A — 1612 (732) WS34 V24R47E22EE 300 1 at +5% 2 at –5% DT-3 150 919E — 1652 (750) WS35 V24R47E33EE 500 1 at +5% 2 at –5% DT-3 150 919E — 2695 (1224) WS35 V24R47E55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 345C 240 (109) WS38 V24M47F15EEES 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 345C 389 (177) WS38 V24M47F30EEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 345C 396 (180) WS38 V24M47F45EEES 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 345C 593 (269) WS39 V24M47F75EEES 112.5 1 at +5% 2 at –5% DT-3 115 916A — 941 (427) WS19 V24R47F12EEES 150 1 at +5% 2 at –5% DT-3 115 916A — 1060 (481) WS19 V24R47F49EEES 225 1 at +5% 2 at –5% DT-3 115 918A — 1500 (681) WS34 V24R47F22EEES 300 1 at +5% 2 at –5% DT-3 115 919E — 1800 (817) WS35 V24R47F33EEES 500 1 at +5% 2 at –5% DT-3 115 919E — 2900 (1317) WS35 V24R47F55EEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 345C 280 (127) WS38 V24M47B15EEES 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 345C 350 (159) WS38 V24M47B30EEES 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 345C 560 (254) WS39 V24M47B45EEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 345C 883 (401) WS19 V24M47B75EEES 112.5 1 at +5% 2 at –5% DT-3 80 916A — 950 (431) WS19 V24R47B12EEES 150 1 at +5% 2 at –5% DT-3 80 918A — 1430 (649) WS34 V24R47B49EEES 225 1 at +5% 2 at –5% DT-3 80 919E — 1750 (795) WS35 V24R47B22EEES 300 1 at +5% 2 at –5% DT-3 80 919E — 2400 (1090) WS35 V24R47B33EEES 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-37 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings 2 440 Delta Volts to 220Y/127 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283Q 213 (97) WS38 V44M31E15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283Q 300 (136) WS38 V44M31E30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283Q 348 (158) WS38 V44M31E45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283Q 583 (265) WS39 V44M31E75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283Q 807 (366) WS19 V44M31E12EE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 283Q 950 (431) WS19 V44M31E49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 283Q 1364 (619) WS34 V44M31E22EE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 918A 283Q 1719 (780) WS34 V44M31E33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 283Q 2560 (1162) WS35 V44M31E55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283Q 204 (93) WS38 V44M31F15EEES 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283Q 326 (148) WS38 V44M31F30EEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283Q 419 (190) WS38 V44M31F45EEES 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283Q 560 (254) WS39 V44M31F75EEES 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283Q 805 (365) WS19 V44M31F12EEES 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 283Q 1012 (459) WS19 V44M31F49EEES 2 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 283Q 1589 (721) WS34 V44M31F22EEES 300 2 at +2.5% 4 at –2.5% DT-3 115 923 283Q 1782 (809) WS37 V44M31F33EEES 2 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 283Q 3117 (1415) WS35 V44M31F55EEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283Q 294 (133) WS38 V44M31B15EEES 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283Q 374 (170) WS38 V44M31B30EEES 2 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283Q 586 (266) WS39 V44M31B45EEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283Q 807 (366) WS19 V44M31B75EEES 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 283Q 1005 (456) WS19 V44M31B12EEES 2 2 2 2 Full Capacity Taps 150 2 at +2.5% 4 at –2.5% DT-3 80 917 283Q 1170 (531) WS34 V44M31B49EEES 225 2 at +2.5% 4 at –2.5% DT-3 80 923 283Q 1764 (801) WS37 V44M31B22EEES 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 283Q 2317 (1052) WS35 V44M31B33EEES Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-38 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings 2 2 480 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 213 (97) WS38 V48M28E15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 300 (136) WS38 V48M28E30EE 37.5 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 345 (157) WS38 V48M28E37EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 348 (158) WS38 V48M28E45EE 50 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 550 (250) WS39 V48M28E50EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 583 (265) WS39 V48M28E75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 807 (366) WS19 V48M28E12EE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 950 (431) WS19 V48M28E49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 928 658B 1371 (622) WS41 V48M28E22EE 300 2 at +2.5% 4 at –2.5% DT-3 150 929 658B 1719 (780) WS42 V48M28E33EE 500 2 at +2.5% 2 at –2.5% DT-3 150 924 487A 2560 (1162) WS40 V48D28E55EE 750 2 at +2.5% 4 at –2.5% DT-3 150 920E 292A 3370 (1530) WS35 V48M28E77EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 204 (93) WS38 V48M28F15EEES 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 326 (148) WS38 V48M28F30EEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 419 (190) WS38 V48M28F45EEES 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283B 560 (254) WS39 V48M28F75EEES 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 805 (365) WS19 V48M28F12EEES 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 1012 (459) WS19 V48M28F49EEES 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 283B 1589 (721) WS34 V48M28F22EEES 300 2 at +2.5% 4 at –2.5% DT-3 115 923 283B 1782 (809) WS37 V48M28F33EEES 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 292A 3117 (1415) WS35 V48M28F55EEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 294 (133) WS38 V48M28B15EEES 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 374 (170) WS38 V48M28B30EEES 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283B 586 (266) WS39 V48M28B45EEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 807 (366) WS19 V48M28B75EEES 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 1005 (456) WS19 V48M28B12EEES 150 2 at +2.5% 4 at –2.5% DT-3 80 917 283B 1170 (531) WS34 V48M28B49EEES 225 2 at +2.5% 4 at –2.5% DT-3 80 923 283B 1764 (801) WS37 V48M28B22EEES 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 292A 2317 (1052) WS35 V48M28B33EEES 500 2 at +2.5% 4 at –2.5% DT-3 80 920E 292A 3379 (1534) WS35 V48M28B55EEES 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-39 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings 2 480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 284B 220 (100) WS38 V48M22E15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 284B 293 (133) WS38 V48M22E30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 284B 348 (158) WS38 V48M22E45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 284B 554 (252) WS39 V48M22E75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 284B 820 (372) WS19 V48M22E12EE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 284B 940 (427) WS19 V48M22E49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 284B 1421 (645) WS34 V48M22E22EE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 923 284B 1787 (811) WS37 V48M22E33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 293A 2504 (1137) WS35 V48M22E55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 284B 231 (105) WS38 V48M22F15EEES 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 284B 326 (148) WS38 V48M22F30EEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 284B 397 (180) WS38 V48M22F45EEES 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 284B 615 (279) WS39 V48M22F75EEES 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 284B 805 (365) WS19 V48M22F12EEES 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 284B 1012 (459) WS19 V48M22F49EEES 2 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 284B 1589 (721) WS34 V48M22F22EEES 300 2 at +2.5% 4 at –2.5% DT-3 115 923 284B 1782 (809) WS37 V48M22F33EEES 2 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 293A 3117 (1415) WS35 V48M22F55EEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 284B 294 (133) WS38 V48M22B15EEES 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 284B 374 (170) WS38 V48M22B30EEES 2 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 284B 586 (266) WS39 V48M22B45EEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 284B 807 (366) WS19 V48M22B75EEES 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 284B 1005 (456) WS19 V48M22B12EEES 150 2 at +2.5% 4 at –2.5% DT-3 80 917 284B 1170 (531) WS34 V48M22B49EEES 2 225 2 at +2.5% 4 at –2.5% DT-3 80 923 284B 1764 (801) WS37 V48M22B22EEES 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 293A 2317 (1052) WS35 V48M22B33EEES 2 2 2 Full Capacity Taps Notes 1 Lighting tap limited to 5% of nameplate full load capacity. 2 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-40 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings 2 2 480 Delta Volts to 480Y/277 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 220 (100) WS38 V48M47E15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 293 (133) WS38 V48M47E30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 398 (181) WS38 V48M47E45EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 554 (252) WS39 V48M47E75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 820 (372) WS19 V48M47E12EE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 940 (427) WS19 V48M47E49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 283B 1421 (645) WS34 V48M47E22EE 300 2 at +2.5% 4 at –2.5% DT-3 150 923 283B 1735 (788) WS34 V48M47E33EE 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 292A 2504 (1137) WS35 V48M47E55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 231 (105) WS38 V48M47F15EEES 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 326 (148) WS38 V48M47F30EEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 397 (180) WS38 V48M47F45EEES 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283B 615 (279) WS39 V48M47F75EEES 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 805 (365) WS19 V48M47F12EEES 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 1012 (459) WS19 V48M47F49EEES 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 283B 1589 (721) WS34 V48M47F22EEES 300 2 at +2.5% 4 at –2.5% DT-3 115 923 283B 1782 (809) WS37 V48M47F33EEES 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 292A 3117 (1415) WS35 V48M47F55EEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 294 (133) WS38 V48M47B15EEES 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 374 (170) WS38 V48M47B30EEES 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283B 586 (266) WS39 V48M47B45EEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 807 (366) WS19 V48M47B75EEES 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 1005 (456) WS19 V48M47B12EEES 150 2 at +2.5% 4 at –2.5% DT-3 80 917 283B 1170 (531) WS34 V48M47B49EEES 225 2 at +2.5% 4 at –2.5% DT-3 80 923 283B 1764 (801) WS37 V48M47B22EEES 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 292A 2317 (1052) WS35 V48M47B33EEES 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-41 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings 2 208 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283A 262 (119) WS38 V29M28E15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283A 351 (159) WS38 V29M28E30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283A 453 (206) WS38 V29M28E45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283A 526 (239) WS39 V29M28E75CUEE 112.5 1 at +5% 2 at –5% DT-3 150 916A 287A 930 (422) WS19 V29R28E12CUEE 2 150 1 at +5% 2 at –5% DT-3 150 916A 287A 1242 (564) WS19 V29R28E49CUEE 225 1 at +5% 2 at –5% DT-3 150 917 287A 1900 (863) WS34 V29R28E22CUEE 2 300 1 at +5% 2 at –5% DT-3 150 918A 287A 2300 (1044) WS34 V29R28E33CUEE 2 500 1 at +5% 2 at –5% DT-3 150 919E 287A 3590 (1630) WS35 V29R28E55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283A 266 (121) WS38 V29M28F15CUEEES 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283A 476 (215) WS38 V29M28F30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283A 475 (216) WS38 V29M28F45CUEEES 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 287A 700 (318) WS39 V29M28F75CUEEES 2 112.5 1 at +5% 2 at –5% DT-3 115 916A 287A 935 (424) WS19 V29R28F12CUEEES 150 1 at +5% 2 at –5% DT-3 115 916A 287A 1274 (578) WS19 V29R28F49CUEEES 2 225 1 at +5% 2 at –5% DT-3 115 917 287A 1743 (791) WS34 V29R28F22CUEEES 300 1 at +5% 2 at –5% DT-3 115 919E 287A 2350 (1067) WS35 V29R28F33CUEEES 2 500 1 at +5% 2 at –5% DT-3 115 920E 287A 3690 (1675) WS35 V29R28F55CUEEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283A 381 (173) WS38 V29M28B15CUEEES 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283A 420 (191) WS38 V29M28B30CUEEES 2 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 283A 510 (232) WS38 V29M28B45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 80 914F 283A 940 (427) WS39 V29M28B75CUEEES 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 283A 1300 (590) WS19 V29M28B12CUEEES 150 1 at +5% 2 at –5% DT-3 80 918A 287A 1800 (817) WS34 V29R28B49CUEEES 2 225 1 at +5% 2 at –5% DT-3 80 919E 287A 2400 (1090) WS35 V29R28B22CUEEES 300 1 at +5% 2 at –5% DT-3 80 920E 287A 3800 (1725) WS35 V29R28B33CUEEES 2 2 Full Capacity Taps Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-42 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings 2 2 208 Delta Volts to 480Y/277 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 345A 236 (107) WS38 V29M47E15CUEE 345A 351 (159) WS38 V29M47E30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 75 2 at +2.5% 4 at –2.5% DT-3 150 912D 345A 453 (206) WS38 V29M47E45CUEE 914F 345A 687 (312) WS39 V29M47E75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 315A 930 (422) WS19 V29R47E12CUEE 150 1 at +5% 2 at –5% DT-3 150 916A 315A 1242 (564) WS19 V29R47E49CUEE 225 1 at +5% 2 at –5% DT-3 150 917 315A 1763 (800) WS34 V29R47E22CUEE 2 2 2 2 2 2 300 1 at +5% 2 at –5% DT-3 150 918A 315A 2300 (1044) WS34 V29R47E33CUEE 500 1 at +5% 2 at –5% DT-3 150 919E 315A 3590 (1630) WS35 V29R47E55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 345A 265 (120) WS38 V29M47F15CUEEES 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 345A 475 (215) WS38 V29M47F30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 345A 475 (216) WS38 V29M47F45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 345A 768 (349) WS39 V29M47F75CUEEES 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 345A 935 (424) WS19 V29M47F12CUEEES 150 1 at +5% 2 at –5% DT-3 115 916A 315A 1274 (578) WS19 V29R47F49CUEEES 225 1 at +5% 2 at –5% DT-3 115 917 315A 1743 (791) WS34 V29R47F22CUEEES 300 1 at +5% 2 at –5% DT-3 115 919E 315A 2350 (1067) WS35 V29R47F33CUEEES 500 1 at +5% 2 at –5% DT-3 115 920E 315A 3690 (1675) WS35 V29R47F55CUEEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 345A 381 (173) WS38 V29M47B15CUEEES 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 345A 420 (191) WS38 V29M47B30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 345A 510 (232) WS38 V29M47B45CUEEES 75 1 at +5% 2 at –5% DT-3 80 914F 315A 940 (427) WS39 V29R47B75CUEEES 112.5 1 at +5% 2 at –5% DT-3 80 916A 315A 1300 (590) WS19 V29R47B12CUEEES 150 1 at +5% 2 at –5% DT-3 80 918A 315A 1800 (817) WS34 V29R47B49CUEEES 225 1at +5% 2 at –5% DT-3 80 919E 315A 2400 (1090) WS35 V29R47B22CUEEES 300 1 at +5% 2 at –5% DT-3 80 920E 315A 3800 (1725) WS35 V29R47B33CUEEES 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-43 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings 2 240 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283G 262 (119) WS38 V24M28E15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283G 351 (159) WS38 V24M28E30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283G 453 (206) WS38 V24M28E45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283G 526 (239) WS39 V24M28E75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283G 930 (422) WS19 V24M28E12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 283G 1242 (564) WS19 V24M28E49CUEE 225 1 at +5% 2 at –5% DT-3 150 917 287B 1900 (863) WS34 V24R28E22CUEE 2 300 1 at +5% 2 at –5% DT-3 150 918A 287B 2300 (1044) WS34 V24R28E33CUEE 2 500 1 at +5% 2 at –5% DT-3 150 919E 287B 3590 (1630) WS35 V24R28E55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283G 266 (121) WS38 V24M28F15CUEEES 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283G 475 (215) WS38 V24M28F30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283G 475 (216) WS38 V24M28F45CUEEES 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283G 700 (318) WS39 V24M28F75CUEEES 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283G 935 (424) WS19 V24M28F12CUEEES 150 1 at +5% 2 at –5% DT-3 115 916A 287B 1274 (578) WS19 V24R28F49CUEEES 2 225 1 at +5% 2 at –5% DT-3 115 917 287B 1743 (791) WS34 V24R28F22CUEEES 300 1 at +5% 2 at –5% DT-3 115 918A 287B 2350 (1067) WS34 V24R28F33CUEEES 2 500 1 at +5% 2 at –5% DT-3 115 919E 287B 3690 (1675) WS35 V24R28F55CUEEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283G 381 (173) WS38 V24M28B15CUEEES 2 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283G 420 (191) WS38 V24M28B30CUEEES 2 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283G 510 (232) WS39 V24M28B45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283G 940 (427) WS19 V24M28B75CUEEES 112.5 1 at +5% 2 at –5% DT-3 80 916A 287B 1300 (590) WS19 V24R28B12CUEEES 2 2 2 2 Full Capacity Taps 150 1 at +5% 2 at –5% DT-3 80 917 287B 1800 (817) WS34 V24R28B49CUEEES 225 1 at +5% 2 at –5% DT-3 80 918A 287B 2400 (1090) WS34 V24R28B22CUEEES 300 1 at +5% 2 at –5% DT-3 80 919E 287B 3800 (1725) WS35 V24R28B33CUEEES Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-44 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings 2 2 240 Delta Volts to 480Y/277 Volts Full Capacity Taps 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 345C 262 (119) WS38 V24M47E15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 345C 351 (159) WS38 V24M47E30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 345C 453 (206) WS38 V24M47E45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 345C 526 (239) WS39 V24M47E75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 345C 930 (422) WS19 V24M47E12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 345C 1242 (564) WS19 V24M47E49CUEE 225 1 at +5% 2 at –5% DT-3 150 918A — 1900 (863) WS34 V24R47E22CUEE 300 1 at +5% 2 at –5% DT-3 150 919E — 2300 (1044) WS35 V24R47E33CUEE 500 1 at +5% 2 at –5% DT-3 150 919E — 3590 (1630) WS35 V24R47E55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 345C 266 (121) WS38 V24M47F15CUEEES 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 345C 475 (215) WS38 V24M47F30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 345C 475 (216) WS38 V24M47F45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 345C 700 (318) WS39 V24M47F75CUEEES 112.5 1 at +5% 2 at –5% DT-3 115 916A — 935 (424) WS19 V24R47F12CUEEES 150 1 at +5% 2 at –5% DT-3 115 916A — 1274 (578) WS19 V24R47F49CUEEES 225 1 at +5% 2 at –5% DT-3 115 918A — 1743 (791) WS34 V24R47F22CUEEES 300 1 at +5% 2 at –5% DT-3 115 919E — 2350 (1067) WS35 V24R47F33CUEEES 500 1 at +5% 2 at –5% DT-3 115 919E — 3690 (1675) WS35 V24R47F55CUEEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 345C 381 (173) WS38 V24M47B15CUEEES 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 345C 420 (191) WS38 V24M47B30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 345C 510 (232) WS39 V24M47B45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 345C 940 (427) WS19 V24M47B75CUEEES 112.5 1 at +5% 2 at –5% DT-3 80 916A — 1300 (590) WS19 V24R47B12CUEEES 150 1 at +5% 2 at –5% DT-3 80 918A — 1800 (817) WS34 V24R47B49CUEEES 225 1 at +5% 2 at –5% DT-3 80 919E — 2400 (1090) WS35 V24R47B22CUEEES 300 1 at +5% 2 at –5% DT-3 80 919E — 3800 (1725) WS35 V24R47B33CUEEES 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-45 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings 2 440 Delta Volts to 220Y/127 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283Q 251 (114) WS38 V44M31E15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283Q 353 (160) WS38 V44M31E30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283Q 421 (191) WS38 V44M31E45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283Q 648 (294) WS39 V44M31E75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283Q 910 (413) WS19 V44M31E12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 283Q 1052 (478) WS19 V44M31E49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 283Q 1548 (703) WS34 V44M31E22CUEE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 923 283Q 2029 (921) WS37 V44M31E33CUEE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 283Q 3680 (1671) WS35 V44M31E55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283Q 239 (109) WS38 V44M31F15CUEEES 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283Q 363 (165) WS38 V44M31F30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283Q 442 (201) WS38 V44M31F45CUEEES 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283Q 676 (307) WS39 V44M31F75CUEEES 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283Q 926 (420) WS19 V44M31F12CUEEES 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 283Q 1246 (566) WS19 V44M31F49CUEEES 2 225 2 at +2.5% 4 at –2.5% DT-3 115 917 283Q 1692 (768) WS34 V44M31F22CUEEES 500 2 at +2.5% 4 at –2.5% DT-3 115 923 283Q 2325 (1056) WS37 V44M31F33CUEEES 2 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 283Q 3646 (1655) WS35 V44M31F55CUEEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283Q 331 (150) WS38 V44M31B15CUEEES 2 2 Full Capacity Taps 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283Q 390 (177) WS38 V44M31B30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 283Q 545 (247) WS38 V44M31B45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283Q 956 (434) WS19 V44M31B75CUEEES 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 283Q 1045 (474) WS19 V44M31B12CUEEES 150 2 at +2.5% 4 at –2.5% DT-3 80 917 283Q 1425 (647) WS34 V44M31B49CUEEES 2 225 2 at +2.5% 4 at –2.5% DT-3 80 923 283Q 2082 (945) WS37 V44M31B22CUEEES 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 283Q 3283 (1490) WS35 V44M31B33CUEEES 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 V2-T2-46 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings 2 2 480 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 251 (114) WS38 V48M28E15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 353 (160) WS38 V48M28E30CUEE 37.5 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 415 (188) WS38 V48M28E37CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 421 (191) WS38 V48M28E45CUEE 50 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 647 (294) WS39 V48M28E50CUEE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 648 (294) WS39 V48M28E75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 910 (413) WS19 V48M28E12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 1052 (478) WS19 V48M28E49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 928 658B 1548 (703) WS41 V48M28E22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 150 929 658B 1622 (737) WS42 V48M28E33CUEE 2 2 2 2 2 2 2 500 2 at +2.5% 2 at –2.5% DT-3 150 924 292A 3680 (1671) WS40 V48D28E55CUEE 750 2 at +2.5% 4 at –2.5% DT-3 150 920E 292A 4890 (2220) WS35 V48M28E77CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 239 (109) WS38 V48M28F15CUEEES 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 363 (165) WS38 V48M28F30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 442 (201) WS38 V48M28F45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283B 676 (307) WS39 V48M28F75CUEEES 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 926 (420) WS19 V48M28F12CUEEES 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 1246 (566) WS19 V48M28F49CUEEES 225 2 at +2.5% 4 at –2.5% DT-3 115 917 292A 1692 (768) WS34 V48M28F22CUEEES 300 2 at +2.5% 4 at –2.5% DT-3 115 923 292A 2325 (1056) WS37 V48M28F33CUEEES 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 292A 3646 (1655) WS35 V48M28F55CUEEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 331 (150) WS38 V48M28B15CUEEES 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 390 (177) WS38 V48M28B30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 545 (248) WS38 V48M28B45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 956 (434) WS19 V48M28B75CUEEES 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 1045 (474) WS19 V48M28B12CUEEES 2 150 2 at +2.5% 4 at –2.5% DT-3 80 917 292A 1425 (647) WS34 V48M28B49CUEEES 225 2 at +2.5% 4 at –2.5% DT-3 80 923 292A 2082 (945) WS37 V48M28B22CUEEES 300 2 at +2.5% 4 at– 2.5% DT-3 80 919E 292A 3283 (1490) WS35 V48M28B33CUEEES 500 2 at +2.5% 4 at –2.5% DT-3 80 920E 292A 4800 (2179) WS35 V48M28B55CUEEES Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-47 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings 2 480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 2 Weathershield 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 284B 253 (115) WS38 V48M22E15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 284B 352 (160) WS38 V48M22E30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 284B 415 (188) WS38 V48M22E45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 284B 703 (319) WS39 V48M22E75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 284B 935 (424) WS19 V48M22E12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 284B 1134 (515) WS19 V48M22E49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 284B 1955 (888) WS34 V48M22E22CUEE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 923 284B 2450 (1112) WS37 V48M22E33CUEE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 293A 3547 (1610) WS35 V48M22E55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 284B 248 (113) WS38 V48M22F15CUEEES 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 284B 410 (186) WS38 V48M22F30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 284B 445 (202) WS38 V48M22F45CUEEES 2 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 284B 750 (341) WS39 V48M22F75CUEEES 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 284B 963 (437) WS19 V48M22F12CUEEES 150 2 at +2.5% 4 at –2.5% DT-3 115 916A 284B 1236 (561) WS19 V48M22F49CUEEES 2 225 2 at +2.5% 4 at –2.5% DT-3 115 917 284B 2100 (953) WS34 V48M22F22CUEEES 300 2 at +2.5% 4 at –2.5% DT-3 115 923 284B 2600 (1180) WS37 V48M22F33CUEEES 2 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 293A 3700 (1680) WS35 V48M22F55CUEEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 284B 247 (113) WS38 V48M22B15CUEEES 2 2 Full Capacity Taps Catalog Number 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 284B 460 (209) WS38 V48M22B30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 284B 505 (229) WS38 V48M22B45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 284B 835 (379) WS19 V48M22B75CUEEES 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 284B 1050 (477) WS19 V48M22B12CUEEES 150 2 at +2.5% 4 at –2.5% DT-3 80 917 284B 2250 (1022) WS34 V48M22B49CUEEES 2 225 2 at +2.5% 4 at –2.5% DT-3 80 923 284B 2900 (1317) WS37 V48M22B22CUEEES 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 293A 4000 (1816) WS35 V48M22B33CUEEES 2 2 2 Notes 1 Lighting tap limited to 5% of nameplate full load capacity. 2 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-48 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings 2 2 480 Delta Volts to 480Y/277 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 340 (154) WS38 V48M47E15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 340 (154) WS38 V48M47E30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 430 (195) WS38 V48M47E45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 677 (307) WS39 V48M47E75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 900 (409) WS19 V48M47E12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 1132 (514) WS19 V48M47E49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 283B 1550 (704) WS34 V48M47E22CUEE 2 2 2 2 2 2 300 2 at +2.5% 4 at –2.5% DT-3 150 923 283B 2550 (1158) WS37 V48M47E33CUEE 500 2 at +2.5% 4 at –2.5% DT-3 150 919E 292A 3412 (1549) WS35 V48M47E55CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 258 (117) WS38 V48M47F15CUEEES 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 426 (193) WS38 V48M47F30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 446 (202) WS38 V48M47F45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283B 666 (302) WS39 V48M47F75CUEEES 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 912 (414) WS19 V48M47F12CUEEES 150 2 at +2.5% 4 at –2.5% DT-3 115 917 283B 1600 (726) WS19 V48M47F49CUEEES 225 2 at +2.5% 4 at –2.5% DT-3 115 917 283B 2107 (957) WS34 V48M47F22CUEEES 300 2 at +2.5% 4 at –2.5% DT-3 115 923 283B 2418 (1098) WS37 V48M47F33CUEEES 500 2 at +2.5% 4 at –2.5% DT-3 115 919E 292A 3800 (1725) WS35 V48M47F55CUEEES 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 369 (168) WS38 V48M47B15CUEEES 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 430 (195) WS38 V48M47B30CUEEES 45 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 552 (251) WS38 V48M47B45CUEEES 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 920 (418) WS19 V48M47B75CUEEES 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 1210 (549) WS19 V48M47B12CUEEES 150 2 at +2.5% 4 at –2.5% DT-3 80 917 283B 1702 (773) WS34 V48M47B49CUEEES 225 2 at +2.5% 4 at –2.5% DT-3 80 923 283B 2313 (1050) WS37 V48M47B22CUEEES 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 292A 3100 (1407) WS35 V48M47B22CUEEES 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-49 2.1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Transformers NEMA TP-1 Energy-Efficient Transformers Accessories Please refer to Section 2.7 Page V2-T2-191. Technical Data and Specifications Frequency Enclosures Sound Levels Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Eaton’s ventilated transformers, Types DS-3 and DT-3, use a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Overload Capability Winding Terminations Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Ventilated transformers have leads brought out to terminals that are pre-drilled to accept Cu/Al lugs. Aluminum-wound transformers have aluminum terminals; copper-wound models have copper terminals. Lugs are not supplied with these transformers. Eaton recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 2 40°C 80°C 30°C 150°C 2 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C 2 40°C 150°C 30°C 220°C 2 The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. 2 2 2 2 Average Sound Levels NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 V2-T2-50 Encapsulated (up to 1.2 kV) 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 50.01 to 75.00 50 53 55 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 Series-Multiple Windings 300.01 to 500.00 60 63 59 Series-multiple windings consist of two similar coils in each winding that can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with an “x” or “/” between the voltage ratings, such as voltages of “120/240” or “240 x 480.” If the series-multiple winding is designated by an “x,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 x 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. 500.01 to 700.00 62 65 61 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. For additional information, please refer to Section 2.7 Page V2-T2-191. 2 will likely be higher (as much as 15 dB greater) due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers NEMA TP-1 Energy-Efficient Transformers 2.1 K-Factor Product Description A common industry term for the amount of harmonics produced by a given load is the K-factor. The larger the K-factor, the more harmonics are present. Linear loads, for example, have a K-factor of 1. Transformers may carry a K-factor rating to define the transformer’s ability to withstand the additional heating generated by harmonic currents. Calculating the K-Factor All nonlinear waveforms can be broken down mathematically into a fundamental frequency and its harmonics. IEEE C57.110 establishes a direct relationship between these harmonics and transformer heating. Underwriters Laboratories has established a similar relationship, the K-factor, which is derived by summing the square of the percentage current at a given harmonic level multiplied by the square of the harmonic order. K = ²(Ih)2(h)2 Ih = Percent Current at Harmonic h h = Harmonic Order, i.e., 3rd, 5th, 7th For example, a load that is 90% of the fundamental, 30% of the third harmonic, and 20% of the fifth harmonic would yield (.9)2(1)2 + (.3)2(3)2 + (.2)2(5)2 or a K-factor of 2.62. This load would require an Eaton KT-4 transformer with a K-factor rating of 4. Transformers that carry a K-factor rating define the transformer’s ability to withstand a given harmonic load while operating within the transformer’s insulation class. An analysis of harmonic loads and a calculation of the K-factor must be made to properly apply transformers in any building or facility. Note that the calculated K-factor is not constant because nonlinear loads change throughout the day as equipment and lighting is turned off and on. These harmonic loads also change over the life of the building or facility as equipment is added or removed. Harmonic Currents Harmonic currents are found in nonlinear loads. These currents are generated by various types of equipment including switching mode power supplies that abruptly switch current on and off during each line cycle. Switching mode power supplies or diode-capacitor power supplies convert AC line voltage to low voltage DC. This process is accomplished by charging capacitors during each line cycle with narrow pluses of current that are timecoincident with line voltage peaks. Examples of this equipment include electronic ballasts for fluorescent lighting, personal computers, printers, fax machines, electronic and medical test equipment, uninterruptible power supplies, and solid-state motor drives. Features, Benefits and Functions ● ● ● ● ● ● 600 volt class standard Three-phase, 480 delta– 208Y/120 volt standard Single-phase, 240 x 480 volt–120/240 volt standard 150°C rise standard, 80°C and 115ºC available Three-phase neutrals sized for 200% of rated current Electrostatic shield Note: Electrostatic shields do not reduce harmonic levels. However, because of the nature of switching mode loads, these shields do reduce transient noise in the system, which may affect sensitive computer loads. ● ● ● Aluminum windings (copper optional) Class 220°C insulation Reduced core flux density Note: Reduced core flux prevents the core from saturation and overheating due to voltage distortions caused by harmonic currents. ● ● ● ● ● ● Indoor enclosures (weathershields optional, for outdoor applications) Coils designed to minimize stray losses K4, K13 standard K9, K20, K30, K40, K50 optional Low sound level (–3 dB, –5 dB) available as options Available with NEMA TP-1 efficiency levels Standards and Certifications ● UL listed 2 2 2 2 Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the Uniform Building Code (UBC), International Building Code (IBC) and California Code Title 24. Catalog Number Selection Please refer to Section 2.7 Page V2-T2-187. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note: Nonlinear is synonymous with the term non-sinusoidal. 2 2 Harmonic Currents Found in Nonlinear Loads Cause Wave Shape Distortion and Create Added Stresses on Transformers 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-51 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers 2 Product Selection 2 Single-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 K-4 240 x 480 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 2 DS-3 150 816 261A 222 (101) WS11 HT20P11S15EE 25 2 2 DS-3 150 818 261A 360 (163) WS11 HT20P11S25EE 2 37.5 2 2 DS-3 150 818 261A 365 (166) WS11 HT20P11S37EE 2 2 2 50 DS-3 150 819 261A 560 (254) WS16 HT20P11S50EE 75 2 2 DS-3 150 820 261A 688 (312) WS16 HT20P11S75EE 2 15 2 2 DS-3 115 816 261A 229 (104) WS11 HT20P11F15EE 25 2 2 DS-3 115 818 261A 365 (166) WS11 HT20P11F25EE 2 37.5 2 2 DS-3 115 818 261A 380 (172) WS11 HT20P11F37EE 50 2 2 DS-3 115 819 261A 580 (263) WS16 HT20P11F50EE 2 75 2 2 DS-3 115 820 261A 700 (318) WS16 HT20P11F75EE 2 15 2 2 DS-3 80 816 261A — WS11 HT20P11B15EE 25 2 2 DS-3 80 818 261A — WS11 HT20P11B25EE 2 37.5 2 2 DS-3 80 819 261A — WS16 HT20P11B37EE 50 2 2 DS-3 80 820 261A — WS16 HT20P11B50EE 2 75 2 2 DS-3 80 821 261A 976 (443) WS13 HT20P11B75EE 2 Full Capacity Taps 2 K-13 240 x 480 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 2 DS-3 150 816 261A 247 (112) WS11 NT20P11S15EE 2 25 2 2 DS-3 150 818 261A 370 (168) WS11 NT20P11S25EE 37.5 2 2 DS-3 150 819 261A 580 (263) WS16 NT20P11S37EE 2 50 2 2 DS-3 150 820 261A 700 (318) WS16 NT20P11S50EE 75 2 2 DS-3 150 821 261A 924 (419) WS13 NT20P11S75EE 2 15 2 2 DS-3 115 816 261A 260 (118) WS11 NT20P11F15EE 2 2 2 25 DS-3 115 818 261A 380 (172) WS11 NT20P11F25EE 37.5 2 2 DS-3 115 819 261A 590 (268) WS16 NT20P11F37EE 2 50 2 2 DS-3 115 820 261A 700 (318) WS16 NT20P11F50EE 75 2 2 DS-3 115 821 261A 970 (440) WS13 NT20P11F75EE 2 15 2 2 DS-3 80 816 261A — WS11 NT20P11B15EE 25 2 2 DS-3 80 818 261A — WS11 NT20P11B25EE 2 37.5 2 2 DS-3 80 819 261A — WS16 NT20P11B37EE 2 50 2 2 DS-3 80 820 261A — WS16 NT20P11B50EE 75 2 2 DS-3 80 821 261A — WS13 NT20P11B75EE 2 2 2 Full Capacity Taps Notes 1 Weights subject to change. 2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 V2-T2-52 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 2 K-4 480 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 206 (94) WS38 H48M28T15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 311 (141) WS38 H48M28T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 400 (182) WS38 H48M28T45EE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 547 (248) WS39 H48M28T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 800 (363) WS19 H48M28T12EE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 1010 (459) WS19 H48M28T49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 918A 283B 1680 (763) WS34 H48M28T22EE 300 2 at +2.5% 4 at –2.5% DT-3 150 919E 292A 2122 (963) WS35 H48M28T33EE 500 2 at +2.5% 4 at –2.5% DT-3 150 920E 292A 3201 (1453) WS35 H48M28T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 307 (139) WS38 H48M28F15EE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 313 (142) WS38 H48M28F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 400 (182) WS38 H48M28F45EE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283B 587 (266) WS39 H48M28F75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 947 (430) WS19 H48M28F12EE 150 2 at +2.5% 4 at –2.5% DT-3 115 917 283B 1243 (564) WS34 H48M28F49EE 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 283B 1680 (763) WS34 H48M28F22EE 300 2 at +2.5% 4 at –2.5% DT-3 115 919E 292A 2480 (1126) WS35 H48M28F33EE 500 2 at +2.5% 4 at –2.5% DT-3 115 920E 292A 3280 (1489) WS35 H48M28F55EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 378 (172) WS38 H48M28B15EE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 365 (166) WS38 H48M28B30EE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283B 550 (250) WS39 H48M28B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 774 (351) WS19 H48M28B75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 283B 1380 (627) WS34 H48M28B12EE 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 283B 1604 (728) WS34 H48M28B49EE 225 2 at +2.5% 4 at –2.5% DT-3 80 919E 292A 2336 (1061) WS35 H48M28B22EE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 292A 2689 (1221) WS35 H48M28B33EE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-53 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 K-13 480 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 271 (123) WS38 N48M28T15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 365 (166) WS38 N48M28T30EE 2 45 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 545 (247) WS39 N48M28T45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 812 (369) WS19 N48M28T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 920 (418) WS19 N48M28T12EE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 917 283B 1221 (554) WS34 N48M28T49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 923 283B 1960 (890) WS37 N48M28T22EE 2 300 2 at +2.5% 4 at –2.5% DT-3 150 919E 292A 2358 (1071) WS35 N48M28T33EE 2 500 2 at +2.5% 4 at –2.5% DT-3 150 922 292A 4799 (2179) WS36 N48M28T55EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 332 (151) WS38 N48M28F15EE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 390 (177) WS38 N48M28F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 914F 283B 548 (249) WS39 N48M28F45EE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 808 (367) WS19 N48M28F75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 990 (449) WS19 N48M28F12EE 2 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 292A 1769 (803) WS34 N48M28F49EE 2 225 2 at +2.5% 4 at –2.5% DT-3 115 919E 292A 2306 (1047) WS35 N48M28F22EE 300 2 at +2.5% 4 at –2.5% DT-3 115 919E 292A 3291 (1494) WS35 N48M28F33EE 2 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 315 (143) WS38 N48M28B15EE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 408 (185) WS38 N48M28B30EE 2 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283B 555 (252) WS39 N48M28B45EE 2 Full Capacity Taps 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 838 (380) WS19 N48M28B75EE 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 283B 1367 (621) WS34 N48M28B12EE 2 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 292A 1607 (730) WS34 N48M28B49EE 225 2 at +2.5% 4 at –2.5% DT-3 80 919E 292A 2582 (1172) WS35 N48M28B22EE 300 2 at +2.5% 4 at –2.5% DT-3 80 920E 292A 3228 (1466) WS35 N48M28B33EE 2 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 V2-T2-54 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings 2 2 K-20 480 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 295 (134) WS38 G48M28T15EE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 367 (167) WS38 G48M28T30EE 45 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 563 (256) WS39 G48M28T45EE 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 808 (367) WS19 G48M28T75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 283B 1379 (626) WS34 G48M28T12EE 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 292A 1559 (708) WS34 G48M28T49EE 225 2 at +2.5% 4 at –2.5% DT-3 150 919E 292A 2600 (1180) WS35 G48M28T22EE 300 2 at +2.5% 4 at –2.5% DT-3 150 919E 292A 2968 (1347) WS35 G48M28T33EE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 300 (136) WS38 G48M28F15EE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 403 (183) WS38 G48M28F30EE 45 2 at +2.5% 4 at –2.5% DT-3 115 914F 283B 574 (261) WS39 G48M28F45EE 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 911 (414) WS19 G48M28F75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 283B 1379 (626) WS34 G48M28F12EE 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 292A — WS34 G48M28F49EE 225 2 at +2.5% 4 at –2.5% DT-3 115 919E 292A — WS35 G48M28F22EE 300 2 at +2.5% 4 at –2.5% DT-3 115 919E 292A — WS35 G48M28F33EE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 340 (154) WS38 G48M28B15EE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 405 (184) WS38 G48M28B30EE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283B 580 (263) WS39 G48M28B45EE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 930 (422) WS19 G48M28B75EE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 283B 1400 (636) WS34 G48M28B12EE 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 292A — WS34 G48M28B49EE 225 2 at +2.5% 4 at –2.5% DT-3 80 919E 292A — WS35 G48M28B22EE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 292A — WS35 G48M28B33EE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Weights subject to change. 2 For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-55 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Single-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 K-4 240 x 480 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 2 DS-3 150 816 261A 280 (127) WS11 HT20P11S15CUEE 25 2 2 DS-3 150 818 261A 431 (195) WS11 HT20P11S25CUEE 2 37.5 2 2 DS-3 150 818 261A 437 (198) WS11 HT20P11S37CUEE 2 50 2 2 DS-3 150 819 261A 686 (311) WS16 HT20P11S50CUEE 75 2 2 DS-3 150 820 261A — WS16 HT20P11S75CUEE 2 15 2 2 DS-3 115 816 261A 276 (125) WS11 HT20P11F15CUEE 25 2 2 DS-3 115 818 261A 435 (197) WS11 HT20P11F25CUEE 2 37.5 2 2 DS-3 115 818 261A 440 (200) WS11 HT20P11F37CUEE 2 2 2 50 DS-3 115 820 261A 700 (318) WS16 HT20P11F50CUEE 75 2 2 DS-3 115 821 261A — WS13 HT20P11F75CUEE 2 15 2 2 DS-3 80 816 261A — WS11 HT20P11B15CUEE 25 2 2 DS-3 80 818 261A — WS11 HT20P11B25CUEE 2 37.5 2 2 DS-3 80 819 261A — WS16 HT20P11B37CUEE 50 2 2 DS-3 80 820 261A — WS16 HT20P11B50CUEE 75 2 2 DS-3 80 821 261A — WS13 HT20P11B75CUEE 2 2 2 2 Full Capacity Taps K-13 240 x 480 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 2 DS-3 150 816 261A 283 (128) WS11 NT20P11S15CUEE 2 25 2 2 DS-3 150 818 261A 420 (191) WS11 NT20P11S25CUEE 37.5 2 2 DS-3 150 818 261A 425 (193) WS11 NT20P11S37CUEE 2 50 2 2 DS-3 150 820 261A 690 (313) WS16 NT20P11S50CUEE 2 2 2 75 DS-3 150 821 261A 1056 (479) WS13 NT20P11S75CUEE 15 2 2 DS-3 115 818 261A 411 (186) WS11 NT20P11F15CUEE 2 25 2 2 DS-3 115 818 261A 427 (194) WS11 NT20P11F25CUEE 37.5 2 2 DS-3 115 819 261A 435 (197) WS16 NT20P11F37CUEE 2 50 2 2 DS-3 115 820 261A 710 (322) WS16 NT20P11F50CUEE 75 2 2 DS-3 115 821 261A 1100 (499) WS13 NT20P11F75CUEE 15 2 2 DS-3 80 818 261A — WS11 NT20P11B15CUEE 25 2 2 DS-3 80 818 261A — WS11 NT20P11B25CUEE 37.5 2 2 DS-3 80 819 261A — WS16 NT20P11B37CUEE 50 2 2 DS-3 80 820 261A — WS16 NT20P11B50CUEE 75 2 2 DS-3 80 821 261A — WS13 NT20P11B75CUEE 2 2 2 2 2 2 Notes 1 Weights subject to change. 2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 V2-T2-56 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 2 K-4 480 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 251 (114) WS38 H48M28T15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 326 (148) WS38 H48M28T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 479 (217) WS38 H48M28T45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 463 (210) WS39 H48M28T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 977 (444) WS19 H48M28T12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 1212 (550) WS19 H48M28T49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 917 292A 1815 (824) WS34 H48M28T22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 150 923 283B 2400 (1090) WS37 H48M28T33CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 256 (116) WS38 H48M28F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 341 (155) WS38 H48M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 526 (239) WS38 H48M28F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 115 914F 283B 759 (345) WS39 H48M28F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 1030 (468) WS19 H48M28F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 115 917 283B 1631 (740) WS34 H48M28F49CUEE 2 2 2 2 2 2 2 2 2 2 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 292A 1965 (892) WS34 H48M28F22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 115 923 283B 2337 (1061) WS37 H48M28F33CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 365 (166) WS38 H48M28B15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 424 (192) WS38 H48M28B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283B 653 (296) WS39 H48M28B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 640 (291) WS19 H48M28B75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 1264 (574) WS19 H48M28B12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 80 917 292A 1685 (765) WS34 H48M28B49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 80 923 292A 2096 (952) WS37 H48M28B22CUEE 300 2 at +2.5% 4 at –2.5% DT-3 80 919E 292A 4600 (2087) WS35 H48M28B33CUEE 2 2 2 2 2 Notes 1 Weights subject to change. 2 For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-57 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 K-13 480 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 346 (157) WS38 N48M28T15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 390 (177) WS38 N48M28T30CUEE 2 45 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 623 (283) WS39 N48M28T45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 848 (385) WS19 N48M28T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 1080 (490) WS19 N48M28T12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3 150 917 292A 1431 (650) WS34 N48M28T49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 923 292A 2129 (967) WS37 N48M28T22CUEE 2 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 341 (155) WS38 N48M28F15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 444 (202) WS38 N48M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 914F 283B 598 (271) WS39 N48M28F45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 894 (406) WS19 N48M28F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 1054 (479) WS19 N48M28F12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3 115 917 292A 1399 (635) WS34 N48M28F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 115 923 292A 2088 (948) WS37 N48M28F22CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 370 (168) WS38 N48M28B15CUEE 2 2 2 2 2 2 2 Full Capacity Taps 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 490 (222) WS38 N48M28B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283B 635 (288) WS39 N48M28B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 987 (448) WS19 N48M28B75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 854 (388) WS19 N48M28B12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 283B 1134 (515) WS34 N48M28B49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 80 919 292A 4091 (1857) WS35 N48M28B22CUEE Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-58 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.1 Transformers NEMA TP-1 Energy-Efficient Transformers Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings 2 2 K-20 480 Delta Volts to 208Y/120 Volts Full Capacity Taps Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 2 kVA FCAN FCBN Type ºC Temp. Rise 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 390 (177) WS38 G48M28T15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 431 (196) WS38 G48M28T30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 150 914F 283B 639 (290) WS39 G48M28T45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 905 (411) WS19 G48M28T75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 150 916A 283B 1060 (481) WS19 G48M28T12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 150 917 283B 1808 (821) WS34 G48M28T49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 150 923 283B 2386 (1083) WS37 G48M28T22CUEE 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 400 (182) WS38 G48M28F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 450 (204) WS38 G48M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 115 914F 283B 690 (313) WS39 G48M28F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 283B 1148 (521) WS19 G48M28F75CUEE 2 2 2 2 2 2 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 283B — WS34 G48M28F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 115 923 283B — WS37 G48M28F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3 115 919E 292A — WS35 G48M28F22CUEE 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 400 (182) WS38 G48M28B15CUEE 30 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 441 (200) WS38 G48M28B30CUEE 45 2 at +2.5% 4 at –2.5% DT-3 80 914F 283B 676 (307) WS39 G48M28B45CUEE 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 283B 1140 (518) WS19 G48M28B75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 292A — WS34 G48M28B12CUEE 150 2 at +2.5% 4 at –2.5% DT-3 80 923 292A 2417 (1097) WS37 G48M28B49CUEE 2 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-59 2.1 2 Transformers NEMA TP-1 Energy-Efficient Transformers Accessories Please refer to Section 2.7 Page V2-T2-191. 2 2 Technical Data and Specifications 2 Frequency Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. 2 2 2 2 2 2 2 2 2 2 2 2 2 Overload Capability Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour, and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. 2 2 Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 40°C 80°C 30°C 150°C 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C Average Sound Levels 40°C 150°C 30°C 220°C NEMA ST-20 Average Sound Level, dB The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. Enclosures Eaton ventilated transformers, Type KT, use a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Ventilated transformers have leads brought out to aluminum pads that are predrilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. Eaton recommends that external cables be rated 75°C for ventilated designs. 2 2 2 2 2 2 Sound Levels All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and For additional information, please refer to Section 2.7 Page V2-T2-195. Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 Encapsulated (up to 1.2 kV) 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 50.01 to 75.00 50 53 55 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 500.01 to 700.00 62 65 61 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. 2 2 2 2 2 V2-T2-60 environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.2 Transformers NEMA Premium and E3 Super Efficient Transformers Contents Description Page NEMA Premium Efficient Transformers Features, Benefits and Functions . . . . . . . . . . . Standards and Certifications. . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . E3 Super Efficient Transformers . . . . . . . . . . . . . . V2-T2-62 V2-T2-62 V2-T2-63 V2-T2-63 V2-T2-66 2 2 2 2 2 2 2 2 2 2 2 NEMA Premium® Efficient Transformers Product Description Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Types DS-3, DT-3 ● ● ● ● ● ● ● Ventilated, NEMA 2 enclosure standard Suitable for indoor applications, outdoors when weathershields are also installed Upright mounting only 220ºC insulation system 150ºC rise standard; 115°C or 80°C rise optional Available in single-phase ratings 15–167 kVA, 600 volts primary (DS-3) Available in three-phase ratings 15–1000 kVA and up to 600 volts primary (DT-3) Application Description NEMA Premium Efficient compliant energy-efficient transformers are specifically designed to meet the energy efficiency standards set forth in NEMA publication “NEMA Premium Efficiency Transformer Program Guidelines.” Surveys have shown that the average loading of low voltage dry-type distribution transformers, over a 24-hour period, is approximately 35%. NEMA Premium compliant transformers are optimized to offer maximum efficiency at 35% of nameplate rating. The range of products covered by NEMA Premium Efficient are: NEMA Premium Efficient Product Range Rating Voltage Class Voltage Single-phase 15–333 kVA Dry-Type Rating Three-phase 15–1000 kVA Transformers that are currently specifically excluded from the scope of NEMA Premium Program include: ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Liquid-filled transformers below 10 kVA Dry-type transformers below 15 kVA AC and DC drives transformers Rectifier transformers designed for high harmonics Autotransformers Non-distribution transformers, such as UPS transformers Special impedance or regulation transformers Regulating transformers Sealed and non-ventilated transformers Machine tool transformers Welding transformers Transformers with tap ranges greater than 15% Transformers with a frequency other than 60 Hz Grounding transformers Testing transformers NEMA Premium Efficient Efficiency Levels Tables of Energy Efficiency NEMA Premium Efficiency Levels Dry-Type Distribution Transformers— Low Voltage (600V and below) Single-Phase Three-Phase kVA Efficiency kVA Efficiency 15 98.39 15 97.90 25 98.60 30 98.25 37.5 98.74 45 98.39 50 98.81 75 98.60 75 98.95 112.5 98.74 100 99.02 150 98.81 167 99.09 225 98.95 250 99.16 300 99.02 333 99.23 500 99.09 — — 750 99.16 — — 1000 99.23 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-61 2.2 Transformers NEMA Premium and E3 Super Efficient Transformers 2 Features, Benefits and Functions 2 ● 2 ● 2 2 2 2 ● ● 60 Hz operation (except as noted) Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels Exceed federal energy efficiency requirements for low voltage dry-type distribution transformers effective as of January 1, 2007 2 Standards and Certifications ● UL listed Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the Uniform Building Code (UBC), International Building Code (IBC) and California Code Title 24. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-62 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.2 Transformers NEMA Premium and E3 Super Efficient Transformers Catalog Number Selection 2 Please refer to Section 2.7 Page V2-T2-187. 2 Product Selection Additional Product Selection information begins on Page V2-T2-189. 2 Three-Phase—Type DT-3 60 Hz NEMA Premium Efficient—Copper Windings 2 2 K-1 480 Volts to 208Y/120 Volts Full Capacity Taps 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T15CUN3 30 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T30CUN3 45 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T45CUN3 75 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T75CUN3 112.5 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T12CUN3 150 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T49CUN3 225 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T22CUN3 300 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T33CUN3 15 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F15CUN3 30 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F30CUN3 45 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F45CUN3 75 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F75CUN3 112.5 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F12CUN3 150 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F49CUN3 225 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F22CUN3 300 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F33CUN3 15 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B15CUN3 30 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B30CUN3 45 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B45CUN3 75 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B75CUN3 2 2 2 2 2 2 2 2 2 2 2 2 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B12CUN3 150 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B49CUN3 225 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B22CUN3 2 Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-63 2.2 2 Transformers NEMA Premium and E3 Super Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA Premium Efficient—Copper Windings 2 K-9 480 Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — B48M28T15CUN3 30 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — B48M28T30CUN3 2 45 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — B48M28T45CUN3 2 75 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — B48M28T75CUN3 112.5 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — B48M28T12CUN3 2 150 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — B48M28T49CUN3 225 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — B48M28T22CUN3 2 300 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — B48M28T33CUN3 2 15 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — B48M28F15CUN3 30 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — B48M28F30CUN3 2 45 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — B48M28F45CUN3 75 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — B48M28F75CUN3 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — B48M28F12CUN3 150 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — B48M28F49CUN3 2 225 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — B48M28F22CUN3 2 300 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — B48M28F33CUN3 15 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — B48M28B15CUN3 2 30 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — B48M28B30CUN3 45 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — B48M28B45CUN3 2 75 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — B48M28B75CUN3 112.5 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — B48M28B12CUN3 150 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — B48M28B49CUN3 225 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — B48M28B22CUN3 2 2 2 2 Full Capacity Taps Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-64 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.2 Transformers NEMA Premium and E3 Super Efficient Transformers Three-Phase—Type DT-3 60 Hz NEMA Premium Efficient—Copper Windings 2 2 K-13 480 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at -2.5% DT-3 150 — 283C — — N48M28T15CUN3 30 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — N48M28T30CUN3 45 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — N48M28T45CUN3 75 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — N48M28T75CUN3 2 2 2 2 112.5 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — N48M28T12CUN3 150 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — N48M28T49CUN3 225 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — N48M28T22CUN3 300 2 at +2.5% 4 at –2.5% DT-3 150 — 292A — — N48M28T33CUN3 15 2 at +2.5% 4 at –2.5% DT-3 115 — 283C — — N48M28F15CUN3 30 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — N48M28F30CUN3 45 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — N48M28F45CUN3 75 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — N48M28F75CUN3 112.5 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — N48M28F12CUN3 150 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — N48M28F49CUN3 225 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — N48M28F22CUN3 300 2 at +2.5% 4 at –2.5% DT-3 115 — 292A — — N48M28F33CUN3 15 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — N48M28B15CUN3 30 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — N48M28B30CUN3 45 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — N48M28B45CUN3 75 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — N48M28B75CUN3 112.5 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — N48M28B12CUN3 150 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — N48M28B49CUN3 225 2 at +2.5% 4 at –2.5% DT-3 80 — 292A — — N48M28B22CUN3 2 2 2 2 2 2 Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-65 2.2 Transformers NEMA Premium and E3 Super Efficient Transformers Contents 2 Description 2 Page NEMA Premium Efficient Transformers . . . . . . . . E3 Super Efficient Transformers Features, Benefits and Functions. . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . 2 2 2 V2-T2-61 V2-T2-67 V2-T2-67 V2-T2-68 V2-T2-68 2 2 2 2 2 2 E3 Super Efficient Transformers 2 Product Description 2 2 2 2 2 2 2 2 2 2 2 2 2 Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Types DS-3, DT-3 ● Ventilated, NEMA 2 enclosure standard ● Suitable for indoor applications, outdoors when weathershields are also installed ● Upright mounting only ● 220ºC insulation system ● 150ºC rise standard; 115°C or 80°C rise optional ● Available in single-phase ratings 15–167 kVA, 600 volts primary (DS-3) ● Available in three-phase ratings 15–1000 kVA and up to 600 volts primary (DT-3) Application Description E3 CSL3-2007energyefficient transformers are specifically designed to meet the energy efficiency guidelines as intended in the U.S. Department of Energy 10 CFR Parts 430 and 431, dated October 12, 2007. Surveys have shown that the average loading of low voltage dry-type distribution transformers, over a 24-hour period, is approximately 35%. E3 Efficient transformers are optimized to offer maximum efficiency at 35% of nameplate rating. Additional clarifications regarding CSL3-2007 can be found in NEMA’s whitepaper “Clarifications on the Use of Department of Energy Design—Line 6, 7 and 8 transformers contained within 10 CFR 430 and 431.” The range of products covered by E3 Efficient are: E3 Efficient Product Range 2 Rating 2 Voltage Class Voltage Dry-Type Single-phase 15–333 kVA Rating Three-phase 15–1000 kVA 2 Transformers that are excluded from the scope of E3 Efficient transformers include: ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Liquid-filled transformers below 10 kVA Dry-type transformers below 15 kVA AC and DC drives transformers Rectifier transformers designed for high harmonics Autotransformers Non-distribution transformers, such as UPS transformers Special impedance or regulation transformers Regulating transformers Sealed and non-ventilated transformers Machine tool transformers Welding transformers Transformers with tap ranges greater than 15% Transformers with a frequency other than 60 Hz Grounding transformers Testing transformers 2 2 V2-T2-66 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com E3 Efficient Efficiency Levels Tables of Energy Efficiency E3 Efficiency Levels Dry-Type Distribution Transformers— Low Voltage (600V and below) Single-Phase Three-Phase kVA Efficiency kVA Efficiency 15 98.23 15 97.97 25 98.44 30 98.29 37.5 98.59 45 98.45 50 98.69 75 98.64 75 98.64 112.5 98.77 100 98.90 150 98.86 167 99.03 225 98.97 250 99.12 300 99.04 333 99.18 500 99.16 — — 750 99.24 — — 1000 99.29 Transformers NEMA Premium and E3 Super Efficient Transformers Features, Benefits and Functions ● ● ● ● 60 Hz operation (except as noted) Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels Meet or exceed federal energy efficiency requirements for low voltage dry-type distribution transformers as intended in U.S. DOE Document 10 CFR Parts 430 and 431, dated October 12, 2007. 2.2 Standards and Certifications ● 2 UL listed 2 2 2 Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. 2 2 2 2 Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the Uniform Building Code (UBC), International Building Code (IBC) and California Code Title 24. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-67 2.2 2 Transformers NEMA Premium and E3 Super Efficient Transformers Catalog Number Selection Please refer to Section 2.7 Page V2-T2-187. 2 2 2 2 2 Product Selection Additional Product Selection information begins on Page V2-T2-189. Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient—Copper Windings K-1 480 Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T15CUE3 2 30 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T30CUE3 2 45 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T45CUE3 75 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T75CUE3 2 112.5 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T12CUE3 150 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T49CUE3 2 225 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T22CUE3 300 2 at +2.5% 4 at –2.5% DT-3 150 — 283B — — V48M28T33CUE3 2 15 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F15CUE3 2 30 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F30CUE3 45 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F45CUE3 2 75 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F75CUE3 112.5 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F12CUE3 2 150 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F49CUE3 2 225 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F22CUE3 2 300 2 at +2.5% 4 at –2.5% DT-3 115 — 283B — — V48M28F33CUE3 2 15 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B15CUE3 30 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B30CUE3 2 45 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B45CUE3 75 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B75CUE3 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B12CUE3 2 150 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B49CUE3 225 2 at +2.5% 4 at –2.5% DT-3 80 — 283B — — V48M28B22CUE3 2 Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-68 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.2 Transformers NEMA Premium and E3 Super Efficient Transformers Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient—Copper Windings 2 2 K-9 480 Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 330 (150) WS38 B48M28T15CUE3 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 400 (182) WS38 B48M28T30CUE3 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 283B 630 (286) WS39 B48M28T45CUE3 75 2 at +2.5% 4 at –2.5% DT-3 150 915F 283B 865 (393) WS39 B48M28T75CUE3 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 283B 1520 (690) WS34 B48M28T12CUE3 150 2 at +2.5% 4 at –2.5% DT-3 150 917 283B 1650 (749) WS34 B48M28T49CUE3 225 2 at +2.5% 4 at –2.5% DT-3 150 918A 283B 2090 (949) WS34 B48M28T22CUE3 300 2 at +2.5% 4 at –2.5% DT-3 150 919E 283B 3900 (1771) WS35 B48M28T33CUE3 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 335 (152) WS38 B48M28F15CUE3 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 406 (184) WS38 B48M28F30CUE3 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 283B 635 (288) WS39 B48M28F45CUE3 75 2 at +2.5% 4 at –2.5% DT-3 115 915F 283B 870 (395) WS39 B48M28F75CUE3 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 283B 1526 (693) WS34 B48M28F12CUE3 150 2 at +2.5% 4 at –2.5% DT-3 115 917 283B 1665 (756) WS34 B48M28F49CUE3 2 2 2 2 2 2 2 2 2 2 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 283B 2094 (951) WS34 B48M28F22CUE3 300 2 at +2.5% 4 at –2.5% DT-3 115 919E 283B 3900 (1771) WS35 B48M28F33CUE3 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 406 (184) WS38 B48M28B15CUE3 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 283B 635 (288) WS39 B48M28B30CUE3 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 283B 870 (395) WS39 B48M28B45CUE3 75 2 at +2.5% 4 at –2.5% DT-3 80 917 283B 1526 (693) WS34 B48M28B75CUE3 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 283B 1665 (756) WS34 B48M28B12CUE3 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 283B 2094 (951) WS34 B48M28B49CUE3 225 2 at +2.5% 4 at –2.5% DT-3 80 919E 283B 3900 (1771) WS35 B48M28B22CUE3 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-69 2.2 2 Transformers NEMA Premium and E3 Super Efficient Transformers Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient—Copper Windings 2 K-13 480 Delta Volts to 208Y/120 Volts 2 kVA 2 Full Capacity Taps FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 1 Weathershield Catalog Number 15 2 at +2.5% 4 at -2.5% DT-3 150 912D 283C 325 (148) WS38 N48M28T15CUE3 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 283B 370 (168) WS38 N48M28T30CUE3 2 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 283B 635 (288) WS39 N48M28T45CUE3 2 75 2 at +2.5% 4 at –2.5% DT-3 150 915F 283B 870 (395) WS39 N48M28T75CUE3 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 283B 1526 (693) WS34 N48M28T12CUE3 2 150 2 at +2.5% 4 at –2.5% DT-3 150 917 283B 1665 (756) WS34 N48M28T49CUE3 225 2 at +2.5% 4 at –2.5% DT-3 150 918A 283B 2094 (951) WS34 N48M28T22CUE3 2 300 2 at +2.5% 4 at –2.5% DT-3 150 919E 292A 3900 (1771) WS35 N48M28T33CUE3 2 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 283C 325 (148) WS38 N48M28F15CUE3 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 283B 370 (168) WS38 N48M28F30CUE3 2 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 283B 635 (288) WS39 N48M28F45CUE3 75 2 at +2.5% 4 at –2.5% DT-3 115 915F 283B 870 (395) WS39 N48M28F75CUE3 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 283B 1526 (693) WS34 N48M28F12CUE3 150 2 at +2.5% 4 at –2.5% DT-3 115 917 283B 1665 (756) WS34 N48M28F49CUE3 2 225 2 at +2.5% 4 at –2.5% DT-3 115 918A 283B 2094 (951) WS34 N48M28F22CUE3 2 300 2 at +2.5% 4 at –2.5% DT-3 115 919E 292A 3900 (1771) WS35 N48M28F33CUE3 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 283B 370 (168) WS38 N48M28B15CUE3 2 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 283B 635 (288) WS39 N48M28B30CUE3 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 283B 870 (395) WS39 N48M28B45CUE3 2 75 2 at +2.5% 4 at –2.5% DT-3 80 917 283B 1526 (693) WS34 N48M28B75CUE3 2 2 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 283B 1665 (756) WS34 N48M28B12CUE3 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 283B 2094 (951) WS34 N48M28B49CUE3 225 2 at +2.5% 4 at –2.5% DT-3 80 919E 292A 3900 (1771) WS35 N48M28B22CUE3 Notes 1 Weights subject to change. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-70 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Energy-Efficient Harmonic Mitigating Transformers 2.3 Contents Harmonic Mitigating Transformer Description Page Energy-Efficient Harmonic Mitigating Transformers Standards and Certifications. . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . NEMA TP-1 Efficient . . . . . . . . . . . . . . . . . . . E3 Super Efficient . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . V2-T2-72 V2-T2-72 V2-T2-73 V2-T2-73 V2-T2-81 V2-T2-89 V2-T2-89 2 2 2 2 2 2 2 2 2 2 Product Description Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. The electrical transformer has been a staple of electrical power systems for the past 100+ years. While the types of electrical loads that are being added to our systems today have radically changed, the transformer has stayed relatively the same in design during this time frame. Eaton’s harmonic mitigating transformer (HMT) represents the evolution of the transformer into something that will best provide clean, energyefficient electricity to power the loads of today and tomorrow. The recent shift of our electrical loads from predominately AC consumers (resistive heating elements, incandescent lighting, three-phase motor load) to DC consumers (such as computers, fax machines, Features and Benefits printers, down to the “wall-wart” that recharges the cell phone) requires that our electrical infrastructure changes as well. These new loads now introduce other currents and frequencies into our electrical power systems—commonly known as “harmonics.” Harmonic currents can cause additional heating, which may cause transformers, generators and conductors to become overloaded. Excessive heat is one of the major reasons that standard transformers and conductors fail prematurely. These harmonic currents have various other effects (such as “loss of ride-through capability,” reduced lifespan and mysterious misoperation of equipment) on the components and loads of an electrical distribution system. Eaton’s HMTs, when used properly within an electrical system, will help keep the loads operating the way the manufacturer designed them and keep the facility’s electrical system free from voltage distortion. Three-Phase, Type DT-3 HMT, 60 Hz ● ● ● ● ● ● Harmonic mitigating (cancellation) transformers are a cost-effective means of treating harmful harmonics in an electrical distribution system Reducing harmonic content in electrical systems can result in a more reliable electrical system, lower maintenance costs, less downtime, fewer equipment malfunctions, and lower cooling system capacity Available in a variety of phase-shift configurations that allow flexibility to target specific families of harmonics Harmonic treatment via electromagnetic flux cancellation May be installed as a stand-alone transformer, or included in IFS™ Available in three-phase ratings, 15–500 kVA, up to 600 volts primary ● ● ● ● ● ● ● ● ● ● ● ● ● ● 480 volt to 208/120 volt standard. Additional voltage combinations available 150°C, 115°C or 80°C temperature rise available Copper windings and terminals standard; aluminum available Meet or exceed NEMA TP-1 energy-efficiency level 200% rated neutral Single electrostatic shield for attenuation of common mode and transverse mode noise Approximately 98% efficient when operated in systems with 100% nonlinear load profiles 220°C insulation system Third-party tested for harmonic performance and energy efficiency Meet NEMA ST-20 sound standards Eliminate circulating harmonic currents in primary windings of transformers Enclosures are NEMA 2 drip-proof. The addition of optional weather-shields makes the enclosure NEMA 3R rainproof Harmonic cancellation via electromagnetic flux cancellation. Filters, capacitors or other such devices are not used Help meet IEEE 519 harmonic limits Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-71 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2.3 2 Transformers Energy-Efficient Harmonic Mitigating Transformers Standards and Certifications ● UL listed 2 2 2 2 Industry Standards IEEE 519-1992 Seismic Qualified All Eaton dry-type transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE standards. Harmonic mitigating transformers are UL listed. Proper use of Eaton’s harmonic mitigating transformers within your electrical system will help you to meet the harmonic distortion limits as proposed by IEEE 519-1992, “IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems.” Eaton dry-type distribution transformers are seismically qualified and exceed the requirements of the Uniform Building Code (UBC), International Building Code (IBC) and California Code Title 24. 2 2 2 Catalog Number Selection 2 Energy-Efficient Harmonic Mitigating Transformers X 48 M 28 F 30 TCUEE NEG 2 2 Primary Voltage 1 48 = 480 three-phase, three-wire 60 = 600 three-phase, three-wire 2 2 Secondary Voltage 1 28 = 208/120 three-phase, four-wire 47 = 480/277 three-phase, four-wire Tap Arrangement M = 2 at +2.5%, 4 at –2.5% D = 2 at +2.5%, 2 at –2.5% 2 Temperature Rise F = 115°C (standard) T = 150°C B= 80°C kVA Rating 15 = 15 49 = 150 30 = 30 22 = 225 45 = 45 33 = 300 75 = 75 55 = 500 12 = 112.5 2 2 E3 Efficient Efficiency Levels Tables of Energy Efficiency NEMA Class 1 Efficiency Levels Dry-Type Distribution Transformers— Low Voltage (600V and below) Tables of Energy Efficiency E3 Efficiency Levels Dry-Type Distribution Transformers— Low Voltage (600V and below) 2 Three-Phase Three-Phase kVA Efficiency kVA Efficiency 2 15 97.0 15 97.97 30 97.5 30 98.29 2 45 97.7 45 98.45 2 75 98.0 75 98.64 112.5 98.2 112.5 98.77 2 150 98.3 150 98.86 225 98.5 225 98.97 2 300 98.6 300 99.04 500 98.7 500 99.16 750 98.8 750 99.24 1000 98.9 1000 99.29 2 2 2 2 X = CU = EE = SS = E3 = NEMA TP-1-2002 Efficiency Levels 2 T = TT = Note 1 The most common ratings are shown. Contact Eaton for availability of additional ratings. 2 2 2 V2-T2-72 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Modifications 1 Single thermal sensor (190°C) Two thermal sensors (190°C and 175°C) 50/60 Hz Copper windings (std.) ENERGY STAR label (std.) Grade 304 stainless steel enclosure Super efficient Phase Shift NON = 0º THR = –30º POS = +15º NEG = –15º 2.3 Transformers Energy-Efficient Harmonic Mitigating Transformers Product Selection 2 Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating 2 2 480 Volts to 208Y/120 Volts—Aluminum Windings—Type NON 0-Degree Phase Shift Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 290 (132) WS38 X48M28T15EENON 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 365 (166) WS38 X48M28T30EENON 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 200X 560 (254) WS39 X48M28T45EENON 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 200X 800 (363) WS19 X48M28T75EENON 2 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 200X 1380 (627) WS34 X48M28T12EENON 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 200X 1560 (708) WS34 X48M28T49EENON 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 2400 (1090) WS35 X48M28T22EENON 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 2970 (1348) WS35 X48M28T33EENON 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 360 (163) WS38 X48M28F15EENON 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 405 (184) WS38 X48M28F30EENON 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 200X 575 (261) WS39 X48M28F45EENON 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 200X 900 (409) WS19 X48M28F75EENON 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 200X 1380 (627) WS34 X48M28F12EENON 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 200X 1600 (726) WS34 X48M28F49EENON 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 2600 (1180) WS35 X48M28F22EENON 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3100 (1407) WS35 X48M28F33EENON 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 200X 380 (173) WS38 X48M28B15EENON 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 560 (254) WS39 X48M28B30EENON 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 800 (363) WS39 X48M28B45EENON 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 200X 1380 (627) WS19 X48M28B75EENON 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 200X 1560 (708) WS34 X48M28B12EENON 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 200X 2400 (1090) WS34 X48M28B49EENON 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 2970 (1348) WS35 X48M28B22EENON 300 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 3400 (1544) WS35 X48M28B33EENON Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-73 2.3 2 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating 2 480 Volts to 208Y/120 Volts—Copper Windings—Type NON 0-Degree Phase Shift 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 335 (152) WS38 X48M28T15CUEENON 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 430 (195) WS38 X48M28T30CUEENON 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 200X 627 (285) WS39 X48M28T45CUEENON 2 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 200X 926 (420) WS19 X48M28T75CUEENON 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 200X 1610 (731) WS34 X48M28T12CUEENON 2 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 200X 1800 (817) WS34 X48M28T49CUEENON 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 3580 (1625) WS35 X48M28T22CUEENON Full Capacity Taps 2 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 3500 (1589) WS35 X48M28T33CUEENON 2 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 362 (164) WS38 X48M28F15CUEENON 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 430 (195) WS38 X48M28F30CUEENON 2 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 200X 627 (285) WS39 X48M28F45CUEENON 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 200X 926 (420) WS19 X48M28F75CUEENON 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 200X 1628 (739) WS34 X48M28F12CUEENON 2 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 200X 2001 (908) WS34 X48M28F49CUEENON 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3596 (1633) WS35 X48M28F22CUEENON 2 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3891 (1767) WS35 X48M28F33CUEENON 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 200X 358 (163) WS38 X48M28B15CUEENON 2 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 558 (253) WS39 X48M28B30CUEENON 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 630 (286) WS39 X48M28B45CUEENON 2 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 200X 940 (427) WS19 X48M28B75CUEENON 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 200X 1628 (739) WS34 X48M28B12CUEENON 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 200X 1800 (817) WS34 X48M28B49CUEENON 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 3400 (1544) WS35 X48M28B22CUEENON 300 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 4377 (1987) WS35 X48M28B33CUEENON 2 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-74 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.3 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating 2 2 480 Volts to 208Y/120 Volts—Aluminum Windings—Type THR 30-Degree Phase Shift Full Capacity Taps 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 290 (132) WS38 X48M28T15EETHR 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 365 (166) WS38 X48M28T30EETHR 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 200X 560 (254) WS39 X48M28T45EETHR 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 200X 800 (363) WS19 X48M28T75EETHR Catalog Number 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 200X 1380 (627) WS34 X48M28T12EETHR 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 200X 1560 (708) WS34 X48M28T49EETHR 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 2400 (1090) WS35 X48M28T22EETHR 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 2970 (1348) WS35 X48M28T33EETHR 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 360 (163) WS38 X48M28F15EETHR 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 405 (184) WS38 X48M28F30EETHR 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 200X 575 (261) WS39 X48M28F45EETHR 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 200X 900 (409) WS19 X48M28F75EETHR 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 200X 1380 (627) WS34 X48M28F12EETHR 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 200X 1600 (726) WS34 X48M28F49EETHR 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 2600 (1180) WS35 X48M28F22EETHR 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3100 (1407) WS35 X48M28F33EETHR 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 200X 380 (173) WS38 X48M28B15EETHR 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 560 (254) WS39 X48M28B30EETHR 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 800 (363) WS39 X48M28B45EETHR 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 200X 1380 (627) WS19 X48M28B75EETHR 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 200X 1560 (708) WS34 X48M28B12EETHR 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 200X 2400 (1090) WS34 X48M28B49EETHR 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 2970 (1348) WS35 X48M28B22EETHR 300 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 3400 (1544) WS35 X48M28B33EETHR 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-75 2.3 2 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating 2 480 Volts to 208Y/120 Volts—Copper Windings—Type THR 30-Degree Phase Shift 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 203X 335 (152) WS38 X48M28T15CUEETHR 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 203X 450 (204) WS38 X48M28T30CUEETHR 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 203X 627 (285) WS39 X48M28T45CUEETHR 2 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 203X 855 (388) WS19 X48M28T75CUEETHR 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 203X 1610 (731) WS34 X48M28T12CUEETHR 2 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 203X 1800 (817) WS34 X48M28T49CUEETHR 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 203X 3450 (1566) WS35 X48M28T22CUEETHR 2 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 203X 3894 (1768) WS35 X48M28T33CUEETHR 2 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 203X 362 (164) WS38 X48M28F15CUEETHR 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 203X 450 (204) WS38 X48M28F30CUEETHR 2 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 203X 610 (277) WS39 X48M28F45CUEETHR 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 203X 868 (394) WS19 X48M28F75CUEETHR 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 203X 1643 (746) WS34 X48M28F12CUEETHR 2 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 203X 2001 (908) WS34 X48M28F49CUEETHR 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 203X 3370 (1530) WS35 X48M28F22CUEETHR 2 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 203X 3894 (1768) WS35 X48M28F33CUEETHR 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 203X 358 (163) WS38 X48M28B15CUEETHR 2 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 203X 558 (253) WS39 X48M28B30CUEETHR 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 203X 630 (286) WS39 X48M28B45CUEETHR 2 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 203X 940 (427) WS19 X48M28B75CUEETHR 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 203X 1628 (739) WS34 X48M28B12CUEETHR 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 203X 1800 (817) WS34 X48M28B49CUEETHR 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 203X 3400 (1544) WS35 X48M28B22CUEETHR 300 2 at +2.5% 4 at –2.5% DT-3 80 919EX 203X 4417 (2005) WS35 X48M28B33CUEETHR 2 2 Full Capacity Taps Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-76 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.3 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating 2 2 480 Volts to 208Y/120 Volts—Aluminum Windings—Type NEG –15-Degree Phase Shift Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 2 Weight Lbs (kg) Weathershield 200X 290 (132) WS38 X48M28T15EENEG 200X 365 (166) WS38 X48M28T30EENEG Catalog Number 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 200X 560 (254) WS39 X48M28T45EENEG 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 200X 800 (363) WS19 X48M28T75EENEG 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 200X 1380 (627) WS34 X48M28T12EENEG 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 200X 1560 (708) WS34 X48M28T49EENEG 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 2400 (1090) WS35 X48M28T22EENEG 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 2970 (1348) WS35 X48M28T33EENEG 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 360 (163) WS38 X48M28F15EENEG 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 405 (184) WS38 X48M28F30EENEG 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 200X 575 (261) WS39 X48M28F45EENEG 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 200X 900 (409) WS19 X48M28F75EENEG 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 200X 1380 (627) WS34 X48M28F12EENEG 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 200X 1600 (726) WS34 X48M28F49EENEG 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 2600 (1180) WS35 X48M28F22EENEG 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3100 (1407) WS35 X48M28F33EENEG 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 200X 380 (173) WS38 X48M28B15EENEG 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 560 (254) WS39 X48M28B30EENEG 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 800 (363) WS39 X48M28B45EENEG 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 200X 1380 (627) WS19 X48M28B75EENEG 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 200X 1560 (708) WS34 X48M28B12EENEG 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 200X 2400 (1090) WS34 X48M28B49EENEG 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 2970 (1348) WS35 X48M28B22EENEG 300 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 3400 (1544) WS35 X48M28B33EENEG 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-77 2.3 2 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating 2 480 Volts to 208Y/120 Volts—Copper Windings—Type NEG –15-Degree Phase Shift 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 335 (152) WS38 X48M28T15CUEENEG 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 430 (195) WS38 X48M28T30CUEENEG 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 200X 627 (285) WS39 X48M28T45CUEENEG 2 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 200X 926 (420) WS19 X48M28T75CUEENEG 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 200X 1610 (731) WS34 X48M28T12CUEENEG 2 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 200X 1800 (817) WS34 X48M28T49CUEENEG 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 200X 3580 (1625) WS35 X48M28T22CUEENEG 2 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 200X 3500 (1589) WS35 X48M28T33CUEENEG 2 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 353 (160) WS38 X48M28F15CUEENEG 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 430 (195) WS38 X48M28F30CUEENEG 2 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 200X 627 (285) WS39 X48M28F45CUEENEG 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 200X 926 (420) WS19 X48M28F75CUEENEG 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 200X 1628 (739) WS34 X48M28F12CUEENEG 2 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 200X 2001 (908) WS34 X48M28F49CUEENEG 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 200X 3596 (1633) WS35 X48M28F22CUEENEG 2 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 200X 3891 (1767) WS35 X48M28F33CUEENEG 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 200X 358 (163) WS38 X48M28B15CUEENEG 2 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 558 (253) WS39 X48M28B30CUEENEG 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 630 (286) WS39 X48M28B45CUEENEG 2 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 200X 940 (427) WS19 X48M28B75CUEENEG 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 200X 1628 (739) WS34 X48M28B12CUEENEG 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 200X 1800 (817) WS34 X48M28B49CUEENEG 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 200X 3400 (1544) WS35 X48M28B22CUEENEG 300 2 at +2.5% 4 at –2.5% DT-3 80 920EX 200X 4377 (1987) WS35 X48M28B33CUEENEG 2 2 2 2 Full Capacity Taps Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-78 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.3 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating 2 2 480 Volts to 208Y/120 Volts—Aluminum Windings—Type POS +15-Degree Phase Shift Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 45 2 at +2.5% 4 at –2.5% DT-3 150 75 2 at +2.5% 4 at –2.5% DT-3 150 2 Weight Lbs (kg) Weathershield Catalog Number 200X 290 (132) WS38 X48M28T15EEPOS 200X 365 (166) WS38 X48M28T30EEPOS 915F 200X 560 (254) WS39 X48M28T45EEPOS 916A 200X 800 (363) WS19 X48M28T75EEPOS 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 200X 1380 (627) WS34 X48M28T12EEPOS 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 200X 1560 (708) WS34 X48M28T49EEPOS 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 2400 (1090) WS35 X48M28T22EEPOS 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 2970 (1348) WS35 X48M28T33EEPOS 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 360 (163) WS38 X48M28F15EEPOS 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 405 (184) WS38 X48M28F30EEPOS 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 200X 575 (261) WS39 X48M28F45EEPOS 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 200X 900 (409) WS19 X48M28F75EEPOS 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 200X 1380 (627) WS34 X48M28F12EEPOS 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 200X 1600 (726) WS34 X48M28F49EEPOS 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 2600 (1180) WS35 X48M28F22EEPOS 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3100 (1407) WS35 X48M28F33EEPOS 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 200X 380 (173) WS38 X48M28B15EEPOS 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 560 (254) WS39 X48M28B30EEPOS 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 800 (363) WS39 X48M28B45EEPOS 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 200X 1380 (627) WS19 X48M28B75EEPOS 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 200X 1560 (708) WS34 X48M28B12EEPOS 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 200X 2400 (1090) WS34 X48M28B49EEPOS 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 2970 (1348) WS35 X48M28B22EEPOS 300 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 3400 (1544) WS35 X48M28B33EEPOS 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-79 2.3 2 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating 2 480 Volts to 208Y/120 Volts—Copper Windings—Type POS +15-Degree Phase Shift 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 335 (152) WS38 X48M28T15CUEEPOS 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 430 (195) WS38 X48M28T30CUEEPOS 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 200X 627 (285) WS39 X48M28T45CUEEPOS 2 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 200X 926 (420) WS19 X48M28T75CUEEPOS 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 200X 1610 (731) WS34 X48M28T12CUEEPOS 2 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 200X 1800 (817) WS34 X48M28T49CUEEPOS 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 3580 (1625) WS35 X48M28T22CUEEPOS Full Capacity Taps 2 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 3500 (1589) WS35 X48M28T33CUEEPOS 2 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 362 (164) WS38 X48M28F15CUEEPOS 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 430 (195) WS38 X48M28F30CUEEPOS 2 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 200X 627 (285) WS39 X48M28F45CUEEPOS 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 200X 926 (420) WS19 X48M28F75CUEEPOS 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 200X 1628 (739) WS34 X48M28F12CUEEPOS 2 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 200X 2001 (908) WS34 X48M28F49CUEEPOS 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3596 (1633) WS35 X48M28F22CUEEPOS 2 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3891 (1767) WS35 X48M28F33CUEEPOS 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 200X 358 (163) WS38 X48M28B15CUEEPOS 2 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 558 (253) WS39 X48M28B30CUEEPOS 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 630 (286) WS39 X48M28B45CUEEPOS 2 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 200X 940 (427) WS19 X48M28B75CUEEPOS 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 200X 1628 (739) WS34 X48M28B12CUEEPOS 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 200X 1800 (817) WS34 X48M28B49CUEEPOS 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 3400 (1544) WS35 X48M28B22CUEEPOS 300 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 4377 (1987) WS35 X48M28B33CUEEPOS 2 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-80 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.3 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating 2 2 480 Volts to 208Y/120 Volts—Aluminum Windings—Type NON 0-Degree Phase Shift Full Capacity Taps kVA FCAN FCBN Type ºC Temp Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T15E3NON 30 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T30E3NON 45 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T45E3NON 75 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T75E3NON 112.5 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T12E3NON 150 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T49E3NON 225 2 at +2.5% 4 at –2.5% DT-3 150 — 201X — — X48M28T22E3NON 300 2 at +2.5% 4 at –2.5% DT-3 150 — 201X — — X48M28T33E3NON 15 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F15E3NON 30 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F30E3NON 45 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F45E3NON 75 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F75E3NON 112.5 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F12E3NON 150 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F49E3NON 225 2 at +2.5% 4 at –2.5% DT-3 115 — 201X — — X48M28F22E3NON 300 2 at +2.5% 4 at –2.5% DT-3 115 — 201X — — X48M28F33E3NON 15 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B15E3NON 30 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B30E3NON 45 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B45E3NON 75 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B75E3NON 112.5 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B12E3NON 150 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B49E3NON 225 2 at +2.5% 4 at –2.5% DT-3 80 — 201X — — X48M28B22E3NON 300 2 at +2.5% 4 at –2.5% DT-3 80 — 201X — — X48M28B33E3NON 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-81 2.3 2 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating 2 480 Volts to 208Y/120 Volts—Copper Windings—Type NON 0-Degree Phase Shift 2 kVA FCAN FCBN Type ºC Temp Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 335 (152) WS38 X48M28T15CUE3NON 2 2 2 2 2 Full Capacity Taps 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 430 (195) WS38 X48M28T30CUE3NON 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 200X 627 (285) WS39 X48M28T45CUE3NON X48M28T75CUE3NON 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 200X 926 (420) WS19 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 200X 1610 (731) WS34 X48M28T12CUE3NON 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 200X 1800 (817) WS34 X48M28T49CUE3NON 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 3580 (1625) WS35 X48M28T22CUE3NON 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 3500 (1589) WS35 X48M28T33CUE3NON 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 362 (164) WS38 X48M28F15CUE3NON 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 430 (195) WS38 X48M28F30CUE3NON 2 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 200X 627 (285) WS39 X48M28F45CUE3NON 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 200X 926 (420) WS19 X48M28F75CUE3NON 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 200X 1628 (739) WS34 X48M28F12CUE3NON 2 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 200X 2001 (908) WS34 X48M28F49CUE3NON 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3596 (1633) WS35 X48M28F22CUE3NON 2 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3891 (1767) WS35 X48M28F33CUE3NON 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 200X 358 (163) WS38 X48M28B15CUE3NON 2 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 558 (253) WS39 X48M28B30CUE3NON 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 630 (286) WS39 X48M28B45CUE3NON 2 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 200X 940 (427) WS19 X48M28B75CUE3NON 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 200X 1628 (739) WS34 X48M28B12CUE3NON 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 200X 1800 (817) WS34 X48M28B49CUE3NON 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 3400 (1544) WS35 X48M28B22CUE3NON 300 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 4377 (1987) WS35 X48M28B33CUE3NON 2 2 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-82 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.3 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating 2 2 480 Volts to 208Y/120 Volts—Aluminum Windings—Type THR 30-Degree Phase Shift Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T15E3THR 30 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T30E3THR 45 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T45E3THR 75 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T75E3THR 112.5 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T12E3THR 150 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T49E3THR 225 2 at +2.5% 4 at –2.5% DT-3 150 — 201X — — X48M28T22E3THR 300 2 at +2.5% 4 at –2.5% DT-3 150 — 201X — — X48M28T33E3THR 15 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F15E3THR 30 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F30E3THR 45 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F45E3THR 75 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F75E3THR 112.5 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F12E3THR 150 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F49E3THR 225 2 at +2.5% 4 at –2.5% DT-3 115 — 201X — — X48M28F22E3THR 300 2 at +2.5% 4 at –2.5% DT-3 115 — 201X — — X48M28F33E3THR 15 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B15E3THR 30 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B30E3THR 45 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B45E3THR 75 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B75E3THR 112.5 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B12E3THR 150 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B49E3THR 225 2 at +2.5% 4 at –2.5% DT-3 80 — 201X — — X48M28B22E3THR 300 2 at +2.5% 4 at –2.5% DT-3 80 — 201X — — X48M28B33E3THR 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-83 2.3 2 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating 2 480 Volts to 208Y/120 Volts—Copper Windings—Type THR 30-Degree Phase Shift 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 203X 335 (152) WS38 X48M28T15CUE3THR 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 203X 450 (204) WS38 X48M28T30CUE3THR 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 203X 627 (285) WS39 X48M28T45CUE3THR 2 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 203X 855 (388) WS19 X48M28T75CUE3THR 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 203X 1610 (731) WS34 X48M28T12CUE3THR 2 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 203X 1800 (817) WS34 X48M28T49CUE3THR 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 203X 3450 (1566) WS35 X48M28T22CUE3THR 2 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 203X 3894 (1768) WS35 X48M28T33CUE3THR 2 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 203X 362 (164) WS38 X48M28F15CUE3THR 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 203X 450 (204) WS38 X48M28F30CUE3THR 2 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 203X 610 (277) WS39 X48M28F45CUE3THR 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 203X 868 (394) WS19 X48M28F75CUE3THR 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 203X 1643 (746) WS34 X48M28F12CUE3THR 2 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 203X 2001 (908) WS34 X48M28F49CUE3THR 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 203X 3370 (1530) WS35 X48M28F22CUE3THR 2 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 203X 3894 (1768) WS35 X48M28F33CUE3THR 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 203X 358 (163) WS38 X48M28B15CUE3THR 2 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 203X 558 (253) WS39 X48M28B30CUE3THR 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 203X 630 (286) WS39 X48M28B45CUE3THR 2 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 203X 940 (427) WS19 X48M28B75CUE3THR 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 203X 1628 (739) WS34 X48M28B12CUE3THR 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 203X 1800 (817) WS34 X48M28B49CUE3THR 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 203X 3400 (1544) WS35 X48M28B22CUE3THR 2 2 Full Capacity Taps Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-84 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.3 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating 2 2 480 Volts to 208Y/120 Volts—Aluminum Windings—Type NEG –15-Degree Phase Shift Full Capacity Taps 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at -2.5% DT-3 150 — 200X — — X48M28T15E3NEG 30 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T30E3NEG 45 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T45E3NEG 75 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T75E3NEG 112.5 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T12E3NEG 150 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T49E3NEG 225 2 at +2.5% 4 at –2.5% DT-3 150 — 201X — — X48M28T22E3NEG 300 2 at +2.5% 4 at –2.5% DT-3 150 — 201X — — X48M28T33E3NEG 15 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F15E3NEG 30 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F30E3NEG 45 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F45E3NEG 75 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F75E3NEG 112.5 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F12E3NEG 150 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F49E3NEG 225 2 at +2.5% 4 at –2.5% DT-3 115 — 201X — — X48M28F22E3NEG 300 2 at +2.5% 4 at –2.5% DT-3 115 — 201X — — X48M28F33E3NEG 15 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B15E3NEG 30 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B30E3NEG 45 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B45E3NEG 75 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B75E3NEG 112.5 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B12E3NEG 150 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B49E3NEG 225 2 at +2.5% 4 at –2.5% DT-3 80 — 201X — — X48M28B22E3NEG 300 2 at +2.5% 4 at –2.5% DT-3 80 — 201X — — X48M28B33E3NEG 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-85 2.3 2 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating 2 480 Volts to 208Y/120 Volts—Copper Windings—Type NEG –15-Degree Phase Shift 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 335 (152) WS38 X48M28T15CUE3NEG 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 430 (195) WS38 X48M28T30CUE3NEG 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 200X 627 (285) WS39 X48M28T45CUE3NEG 2 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 200X 926 (420) WS19 X48M28T75CUE3NEG 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 200X 1610 (731) WS34 X48M28T12CUE3NEG 2 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 200X 1800 (817) WS34 X48M28T49CUE3NEG 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 200X 3580 (1625) WS35 X48M28T22CUE3NEG 2 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 200X 3500 (1589) WS35 X48M28T33CUE3NEG 2 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 353 (160) WS38 X48M28F15CUE3NEG 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 430 (195) WS38 X48M28F30CUE3NEG 2 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 200X 627 (285) WS39 X48M28F45CUE3NEG 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 200X 926 (420) WS19 X48M28F75CUE3NEG 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 200X 1628 (739) WS34 X48M28F12CUE3NEG 2 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 200X 2001 (908) WS34 X48M28F49CUE3NEG 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 200X 3596 (1633) WS35 X48M28F22CUE3NEG 2 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 200X 3891 (1767) WS35 X48M28F33CUE3NEG 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 200X 358 (163) WS38 X48M28B15CUE3NEG 2 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 558 (253) WS39 X48M28B30CUE3NEG 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 630 (286) WS39 X48M28B45CUE3NEG 2 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 200X 940 (427) WS19 X48M28B75CUE3NEG 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 200X 1628 (739) WS34 X48M28B12CUE3NEG 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 200X 1800 (817) WS34 X48M28B49CUE3NEG 2 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 200X 3400 (1544) WS35 X48M28B22CUE3NEG 300 2 at +2.5% 4 at –2.5% DT-3 80 920EX 200X 4377 (1987) WS35 X48M28B33CUE3NEG 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. Full Capacity Taps 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-86 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.3 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating 2 2 480 Volts to 208Y/120 Volts—Aluminum Windings—Type POS +15-Degree Phase Shift Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T15E3POS 30 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T30E3POS 45 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T45E3POS 75 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T75E3POS 112.5 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T12E3POS 150 2 at +2.5% 4 at –2.5% DT-3 150 — 200X — — X48M28T49E3POS 225 2 at +2.5% 4 at –2.5% DT-3 150 — 201X — — X48M28T22E3POS 300 2 at +2.5% 4 at –2.5% DT-3 150 — 201X — — X48M28T33E3POS 15 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F15E3POS 30 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F30E3POS 45 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F45E3POS 75 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F75E3POS 112.5 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F12E3POS 150 2 at +2.5% 4 at –2.5% DT-3 115 — 200X — — X48M28F49E3POS 225 2 at +2.5% 4 at –2.5% DT-3 115 — 201X — — X48M28F22E3POS 300 2 at +2.5% 4 at –2.5% DT-3 115 — 201X — — X48M28F33E3POS 15 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B15E3POS 30 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B30E3POS 45 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B45E3POS 75 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B75E3POS 112.5 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B12E3POS 150 2 at +2.5% 4 at –2.5% DT-3 80 — 200X — — X48M28B49E3POS 225 2 at +2.5% 4 at –2.5% DT-3 80 — 201X — — X48M28B22E3POS 300 2 at +2.5% 4 at –2.5% DT-3 80 — 201X — — X48M28B33E3POS 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-87 2.3 2 Transformers Energy-Efficient Harmonic Mitigating Transformers Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating 2 480 Volts to 208Y/120 Volts—Copper Windings—Type POS +15-Degree Phase Shift 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 335 (152) WS38 X48M28T15CUE3POS 2 30 2 at +2.5% 4 at –2.5% DT-3 150 912D 200X 430 (195) WS38 X48M28T30CUE3POS 45 2 at +2.5% 4 at –2.5% DT-3 150 915F 200X 627 (285) WS39 X48M28T45CUE3POS 2 75 2 at +2.5% 4 at –2.5% DT-3 150 916A 200X 926 (420) WS19 X48M28T75CUE3POS 112.5 2 at +2.5% 4 at –2.5% DT-3 150 917 200X 1610 (731) WS34 X48M28T12CUE3POS 2 150 2 at +2.5% 4 at –2.5% DT-3 150 918A 200X 1800 (817) WS34 X48M28T49CUE3POS 225 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 3580 (1625) WS35 X48M28T22CUE3POS 2 300 2 at +2.5% 4 at –2.5% DT-3 150 919EX 201X 3500 (1589) WS35 X48M28T33CUE3POS 2 15 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 362 (164) WS38 X48M28F15CUE3POS 30 2 at +2.5% 4 at –2.5% DT-3 115 912D 200X 430 (195) WS38 X48M28F30CUE3POS 2 45 2 at +2.5% 4 at –2.5% DT-3 115 915F 200X 627 (285) WS39 X48M28F45CUE3POS 75 2 at +2.5% 4 at –2.5% DT-3 115 916A 200X 926 (420) WS19 X48M28F75CUE3POS 2 112.5 2 at +2.5% 4 at –2.5% DT-3 115 917 200X 1628 (739) WS34 X48M28F12CUE3POS 2 150 2 at +2.5% 4 at –2.5% DT-3 115 918A 200X 2001 (908) WS34 X48M28F49CUE3POS 225 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3596 (1633) WS35 X48M28F22CUE3POS 2 300 2 at +2.5% 4 at –2.5% DT-3 115 919EX 201X 3891 (1767) WS35 X48M28F33CUE3POS 15 2 at +2.5% 4 at –2.5% DT-3 80 912D 200X 358 (163) WS38 X48M28B15CUE3POS 2 30 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 558 (253) WS39 X48M28B30CUE3POS 45 2 at +2.5% 4 at –2.5% DT-3 80 915F 200X 630 (286) WS39 X48M28B45CUE3POS 2 75 2 at +2.5% 4 at –2.5% DT-3 80 916A 200X 940 (427) WS19 X48M28B75CUE3POS 2 112.5 2 at +2.5% 4 at –2.5% DT-3 80 917 200X 1628 (739) WS34 X48M28B12CUE3POS 150 2 at +2.5% 4 at –2.5% DT-3 80 918A 200X 1800 (817) WS34 X48M28B49CUE3POS 225 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 3400 (1544) WS35 X48M28B22CUE3POS 300 2 at +2.5% 4 at –2.5% DT-3 80 919EX 201X 4377 (1987) WS35 X48M28B33CUE3POS 2 2 Full Capacity Taps Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-88 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.3 Transformers Energy-Efficient Harmonic Mitigating Transformers Accessories 2 Harmonic mitigating transformers are available with the same options and accessories as generalpurpose ventilated transformers. Please refer to Section 2.7 Page V2-T2-191. 2 2 2 2 Technical Data and Specifications Frequency Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet Insulation System Classification Average Sound Levels Overload Capacity Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one hour and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. 2 Sound Levels Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 40°C 80°C 30°C 150°C 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C 40°C 150°C 30°C 220°C NEMA ST-20 levels listed here. Lower sound levels are available and must be designed specially. 2 2 2 2 NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) K-Factor 1, 4, 9 K-Factor 13, 20 kVA Range Encapsulated (up to 1.2 kV) 2 2 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. 50.01 to 75.00 50 53 55 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 Enclosures 500.01 to 700.00 62 65 61 Eaton ventilated transformers Types DS-3 and DT-3 use a NEMA 2 rated (drip-proof) enclosure as a standard, and are rated NEMA 3R with the addition of weathershields. 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory 2 2 2 2 2 2 Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-89 2.3 Transformers Energy-Efficient Harmonic Mitigating Transformers 2 Demystifying Harmonic Mitigating Transformer Myths 2 Aren’t “power factor corrected” computer power supplies fixing all harmonics? The use of power factor corrected computer power supplies is a great first start to reducing harmonic currents in your facility. These are becoming prevalent in server applications, but have not “crossed-over” into the laptop computer/business computer. Remember also that, once the computer power supply harmonics are addressed, you will still need to address the harmonic currents coming from the variety of other equipment in your facility. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Don’t K-rated transformers fix harmonics? The K-rated transformer was created to address the additional heat being produced by standard deltawye transformers when feeding nonlinear loads. The goal of the K-rated transformer is to dissipate the heat produced over a larger area, thus providing the illusion of correction. The K-rated transformer does nothing to reduce the root issue of harmonic currents or correct power quality issues. Because of their larger size, they also consume additional energy to “do the same work” and are counter-productive to an energy-efficient electrical distribution design. Don’t you need two HMTs for any correction to occur? The design of HMTs allows them to address different families of harmonic currents in different ways. A single HMT will treat the triplen (3rd, 9th, 15th and so on) harmonic currents in its secondary winding. The 5th, 7th, 17th and 19th harmonic family is treated on a system basis through a technique known as “phase shifting.” This phase shift does occur between the Type NON and Type THR, and the Type POS and Type NEG harmonic mitigating transformers—and this can also occur between a Type NON and a standard delta-wye transformer (that is probably already existing within your facility). See our Sample HMT Applications area for additional information. The cost of HMTs is too high! While the initial cost of HMTs is typically 1.5 to 4 times the cost of a standard transformer (due to the additional design, materials and labor involved in creating the magnetics necessary to reduce harmonic impact)—to not use an HMT in a harmonic environment will actually cost you 250% more energy loss in the transformer. Due to the relatively long life of a transformer (20–30 years), these additional energy costs easily overshadow the initial one-time first cost increment. If I use one HMT, don’t I need to change all my transformers? Most facilities have only a percentage (typically 20–25%) of their electrical system that really requires the use of an HMT. This means in a typical building that only a few areas are either critical (meaning high requirements for “clean” power) or have high concentrations of electronic, nonlinear loads—requiring the use of the HMT in those specific areas. The harmonic mitigating transformer is a weapon in your arsenal in providing a complete, properly designed electrical system for today and tomorrow. Transformer Technology Table Explanation In understanding the product placement of the HMT, it becomes useful to have some “rule of thumb” understanding to compare products. Looking at one of the aspects of an HMT— price—you can see that, if a standard delta-wye transformer had a cost of one unit, a K-13 transformer would cost about double and an HMT would cost 1.5 to 4 times the unit cost. What’s impressive to compare is the next column of information— ”Energy Savings.” If the amount of energy used to power today’s loads is compared against a standard delta-wye transformer (that was never designed to feed today’s types of loads), you can easily see that the HMT is designed to meet the issue head-on! Referring to the table’s information, you can see that it would take 30% more energy to power the same computer loads with a K-13 transformer, whereas an HMT would take 25% less energy to feed those same Transformer Technology Comparison 1 Transformer Type Cost Energy Savings Power Quality Standard delta-wye if 1X if 1X Not designed for harmonics K-13 1.5–2X –0.3X Bulked up—doesn’t help HMT 2.5X 2.5X Corrects root issue Note 1 Comparing cost, energy savings and power quality performance between the “commonly used” transformer types. 2 2 2 V2-T2-90 computer loads. (This is due to the fact that the HMT has a different design than a standard delta-wye transformer and addresses the root issue of harmonic currents.) A good analogy is to look at the incandescent light bulb versus a compact fluorescent lamp—you might pay a bit more up front, but because of the large energy savings (because of the harmonic loading), you soon realize that the upfront cost pales in comparison to the potential of energy saved. Eaton would be happy to provide you with an estimation calculator to help you determine the amount of payback and return on investment (ROI) based on the incremental cost of the HMT. It’s very typical to return the price differential between the HMT and a standard transformer with a few years—thus using the additional 20 to 30 years of energy savings to add to your bottom line. Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Energy-Efficient Harmonic Mitigating Transformers 2.3 Sample HMT Applications Typical Application of Type NON Transformer Type NON 2 Typical Application of Type NON Transformer with a Standard Delta-Wye Transformer Electrical Panel Feeding Single-Phase and/or Three-Phase Nonlinear Loads 2 Type NON -Y Transformer 2 Electrical Panel Feeding Single-Phase and/or Three-Phase Nonlinear Loads 2 2 Type NON Long Run 2 Electrical Bus Installation of a Type NON transformer provides an effective treatment of triplen (3rd, 9th, 15th and so on) harmonic currents that are generated by loads connected to the transformer. Triplen harmonic currents are treated in the secondary windings of the transformer due to the transformer’s low zero sequence impedance. Type NON transformers do not need to be used in combination with other transformers to treat triplen harmonic currents. A single Type NON transformer may be installed, or multiple units can be applied. 2 Type NON Long Run Type NON transformers are an ideal solution for treating triplen harmonics generated by personal computers, printers, fax machines and other office equipment, as well as by single-phase electronic ballasts, and singlephase electronic testing or monitoring devices. Electrical Bus When a delta-wye transformer exists in an electrical distribution system, the addition of a Type NON transformer offers an economical solution for treating harmonic currents. The 30° phase-shift created between a Type NON harmonic mitigating transformer and a delta-wye transformer (standard transformer or K-Factor transformer) provides treatment of 5th, 7th, 17th and 19th harmonic currents. These harmonic currents are canceled in the common electrical bus that feeds the transformers. Additionally, 2 2 -Y Transformer 2 triplen (3rd, 9th, 15th and so on) harmonic currents generated by the loads connected to the Type NON transformer will be treated in the secondary windings of the Type NON transformer due to its low zero sequence impedance. When using two or more transformers to treat harmonics, it is better that the load be split equally between the transformers to receive the maximum benefit. Note: Triplen currents will still circulate in the delta-wye transformer for additional waste. See figure on Page V2-T2-92 to correct. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-91 2.3 2 Transformers Energy-Efficient Harmonic Mitigating Transformers Optimum Application of Type NON and Type THR Transformers 2 Type NON 2 Type THR 2 2 Typical Application of Type NEG and Type POS Transformers Type NEG Electrical Panel Feeding Single-Phase and/or Three-Phase Nonlinear Loads Type POS Type NON 2 2 Long Run Electrical Panel Feeding Single-Phase and/or Three-Phase Nonlinear Loads Type NEG Long Run 2 2 2 2 2 2 2 2 2 2 Type THR Electrical Bus When you’re searching for an optimum harmonic correction solution in an electrical distribution system, the combination of a Type NON and Type THR transformer offers a great solution. The 30° phase shift created between Type NON and type THR harmonic mitigating transformers provides treatment of 5th, 7th, 17th and 19th harmonic currents. These harmonic currents are canceled in the common electrical bus that feeds the transformers. Additionally, triplen (3rd, 9th, 15th and so on) harmonic currents generated by the loads will be treated in the secondary windings of HMTs. This will ensure that these currents will not circulate in the primary of the transformer creating additional heat, voltage distortion and wasted energy loss. When using two or more transformers to treat harmonics, it is better that the load be split equally between the transformers to receive the maximum benefit. Electrical Bus The combination of a Type POS (+15° phase-shift) transformer and a Type NEG (–15° phase-shift) transformer effectively treats 5th, 7th, 17th and 19th harmonic currents. These harmonic currents are canceled in the common electrical bus that feeds the transformers. Additionally, triplen (3rd, 9th, 15th and so on) harmonic 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-92 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Type POS currents generated by the loads connected to these transformers will be treated in their secondary windings due to their low zero sequence impedance. When using two or more transformers to treat harmonics, it is better that the load be split equally between the transformers to receive the maximum benefit. Transformers General-Purpose Encapsulated Transformers 2.4 Contents Type EP 3–25 kVA Description Page General-Purpose Encapsulated Transformers Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . V2-T2-94 V2-T2-94 V2-T2-94 V2-T2-100 V2-T2-109 V2-T2-109 2 2 2 2 2 2 2 2 2 2 Product Description Application Description Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. The basic purpose of a transformer is voltage transformation as near as practically possible to the load for economy and distribution of power. Typical loads for dry-type distribution transformers include lighting, heating, air conditioners, fans and machine tools. Such loads are found in commercial, institutional, industrial and residential structures. Type EP and EPT ● ● ● ● ● ● ● ● Encapsulated design Suitable for indoor or outdoor applications Totally enclosed, nonventilated enclosures Enclosures are NEMA 3R rated Mountable in any position indoors and upright-only outdoors 180ºC insulation system 115ºC rise standard; 80°C optional Available in ratings through 37.5 kVA single-phase; 75 kVA three-phase Features, Benefits and Functions ● ● ● 60 Hz operation (50/60 Hz optional) Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels 2 Standards and Certifications ● ● 2 UL listed CSA certified 2 2 2 Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. 2 2 2 2 2 Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the Uniform Building Code (UBC), International Building Code (IBC), and California Code Title 24. 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-93 2.4 2 2 2 2 2 Transformers General-Purpose Encapsulated Transformers Catalog Number Selection Please refer to Section 2.7 Page V2-T2-187. Product Selection Additional Product Selection information begins on Page V2-T2-189. Single-Phase Encapsulated—Type EP, 60 Hz Type EP 3–37.5 kVA 2 120 x 240 Volts to 120/240 Volts 1 Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 0.5 — — EP 115 FR57P 3E 16 (7) Indoor–Outdoor S10N11P51P 2 1 — — EP 115 FR67P 3E 31 (14) Indoor–Outdoor S10N11P01P 1.5 — — EP 115 FR67P 3E 42 (19) Indoor–Outdoor S10N11P16P 2 2 — — EP 115 FR68P 3E 42 (19) Indoor–Outdoor S10N11P02P 3 — — EP 115 FR176 3E 55 (25) Indoor–Outdoor S10N11S03N 2 5 — — EP 115 FR177 3E 113 (51) Indoor–Outdoor S10N11S05N 2 7.5 — — EP 115 FR178 3E 123 (56) Indoor–Outdoor S10N11S07N 10 — — EP 115 FR179 3E 193 (88) Indoor–Outdoor S10N11S10N 15 — — EP 115 FR180 3E 216 (98) Indoor–Outdoor S10N11S15N 25 — — EP 115 FR182 3E 375 (170) Indoor–Outdoor S10N11S25N 2 2 2 208 Volts to 120/240 Volts 1 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 0.5 — — EP 115 FR57P 26A 16 (7) Indoor–Outdoor S29N11P51P 2 1 — — EP 115 FR67P 26A 31 (14) Indoor–Outdoor S29N11P01P 2 1.5 — — EP 115 FR67P 26A 42 (19) Indoor–Outdoor S29N11P16P 2 — — EP 115 FR68P 26A 42 (19) Indoor–Outdoor S29N11P02P 2 3 — — EP 115 FR176 26A 65 (30) Indoor–Outdoor S29N11S03N 5 — — EP 115 FR177 26A 113 (51) Indoor–Outdoor S29N11S05N 2 7.5 — — EP 115 FR178 26A 123 (56) Indoor–Outdoor S29N11S07N 10 — — EP 115 FR179 26A 193 (88) Indoor–Outdoor S29N11S10N 15 — — EP 115 FR180 26A 216 (98) Indoor–Outdoor S29N11S15N 25 — — EP 115 FR182 26A 395 (179) Indoor–Outdoor S29N11S25N Full Capacity Taps 2 2 Notes 1 Contact Eaton for availability of 0.05–0.25 kVA designs. 2 Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 V2-T2-94 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.4 Transformers General-Purpose Encapsulated Transformers Single-Phase Encapsulated—Type EP, 60 Hz 2 2 277 Volts to 120/240 Volts 1 Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 0.5 — — EP 115 FR58AP 524A 26 (12) Indoor–Outdoor S27N11P51P 1 — — EP 115 FR59AP 524A 31 (14) Indoor–Outdoor S27N11P01P 1.5 — — EP 115 FR67P 524A 42 (19) Indoor–Outdoor S27N11P16P 2 — — EP 115 FR176P 524A 65 (30) Indoor–Outdoor S27N11P02P 3 — — EP 115 FR176 524A 55 (25) Indoor–Outdoor S27N11S03N 5 — — EP 115 FR177 524A 113 (51) Indoor–Outdoor S27N11S05N 7.5 — — EP 115 FR178 524A 123 (56) Indoor–Outdoor S27N11S07N 10 — — EP 115 FR179 524A 193 (88) Indoor–Outdoor S27N11S10N 15 — — EP 115 FR180 524A 180 (82) Indoor–Outdoor S27N11S15N 25 — — EP 115 FR182 524A 375 (170) Indoor–Outdoor S27N11S25N 2 2 2 2 2 2 2 2 240 x 480 Volts to 120/240 Volts Full Capacity Taps 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 0.050 — — EP 115 FR52 3A 7 (3) Indoor–Outdoor S20N11S81N 0.075 — — EP 115 FR54 3A 7 (3) Indoor–Outdoor S20N11S85N 0.100 — — EP 115 FR54 3A 7 (3) Indoor–Outdoor S20N11S82N 0.150 — — EP 115 FR55 3A 8 (4) Indoor–Outdoor S20N11S83N 0.25 — — EP 115 FR57P 3A 12 (5) Indoor–Outdoor S20N11P26P 0.5 — — EP 115 FR57P 3A 16 (7) Indoor–Outdoor S20N11P51P 0.75 — — EP 115 FR58AP 3A 26 (12) Indoor–Outdoor S20N11P76P 1 — — EP 115 FR67P 3A 31 (14) Indoor–Outdoor S20N11P01P 1.5 — — EP 115 FR67P 3A 42 (19) Indoor–Outdoor S20N11P16P 2 — — EP 115 FR68P 3A 42 (19) Indoor–Outdoor S20N11P02P 3 — — EP 115 FR176 3A 65 (30) Indoor–Outdoor S20N11S03N 3 2 2 EP 115 FR176 3A 65 (30) Indoor–Outdoor S20K11S03N 5 — — EP 115 FR177 3A 113 (51) Indoor–Outdoor S20N11S05N 5 2 2 EP 115 FR177 9A 105 (48) Indoor–Outdoor S20K11S05N 7.5 — — EP 115 FR178 3A 105 (48) Indoor–Outdoor S20N11S07N 7.5 2 2 EP 115 FR178 9A 123 (56) Indoor–Outdoor S20K11S07N 10 — — EP 115 FR179 3A 193 (88) Indoor–Outdoor S20N11S10N 10 2 2 EP 115 FR179 9A 193 (88) Indoor–Outdoor S20K11S10N 15 — — EP 115 FR180 3A 216 (98) Indoor–Outdoor S20N11S15N 15 3 3 EP 115 FR180 23A 216 (98) Indoor–Outdoor S20L11S15N 25 — — EP 115 FR182 3A 385 (175) Indoor–Outdoor S20N11S25N 25 3 3 EP 115 FR182 23A 375 (170) Indoor–Outdoor S20L11S25N 37.5 3 3 EP 115 FR300A 248A 735 (334) Indoor–Outdoor S20L11S37 4 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Contact Eaton for availability of 0.05–0.25 kVA designs. 2 1 at +10% FCBN at 240 volts; 2 at –5% FCBN at 480 volts. 3 2 at +5% FCBN at 240 volts; 4 at –2.5% FCBN at 480 volts. 4 Floor-mount only. 2 Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-95 2.4 2 Transformers General-Purpose Encapsulated Transformers Single-Phase Encapsulated—Type EP, 60 Hz 2 190/200/208/220 x 380/400/416/440 Volts to 110/220 Volts 50/60 Hz—Export Model IP 22 Rated 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 0.5 — — EP 115 FR67 538A 42 (19) Indoor–Outdoor S40N14S51CE 1 — — EP 115 FR67 538A 42 (19) Indoor–Outdoor S40N14S01CE 1.5 — — EP 115 FR176 538A 65 (30) Indoor–Outdoor S40N14S16CE 2 2 — — EP 115 FR176 538A 65 (30) Indoor–Outdoor S40N14S02CE 3 — — EP 115 FR177 538A 113 (51) Indoor–Outdoor S40N14S03CE 2 5 — — EP 115 FR178 538A 140 (64) Indoor–Outdoor S40N14S05CE 7.5 — — EP 115 FR179 538A 193 (88) Indoor–Outdoor S40N14S07CE 10 — — EP 115 FR180 538A 216 (98) Indoor–Outdoor S40N14S10CE 15 — — EP 115 FR182 538A 375 (170) Indoor–Outdoor S40N14S15CE 2 2 2 2 Full Capacity Taps 2 120/208/240/277 Volts to 120/240 Volts 60 Hz 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 1 — — EP 115 FR67P 1 42 (19) Indoor–Outdoor S54N11P01 2 Full Capacity Taps 1.5 — — EP 115 FR176P 1 65 (30) Indoor–Outdoor S54N11P16 2 2 — — EP 115 FR176P 1 65 (30) Indoor–Outdoor S54N11P02 — — EP 115 FR177 1 2 3 113 (51) Indoor–Outdoor S54N11S03 5 — — EP 115 FR178 1 140 (64) Indoor–Outdoor S54N11S05 2 7.5 — — EP 115 FR179 1 193 (88) Indoor–Outdoor S54N11S07 10 — — EP 115 FR180 1 216 (98) Indoor–Outdoor S54N11S10 2 2 240 x 480 Volts to 120/240 Volts Stainless Steel 2 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — — EP 115 FR176 3A 65 (30) Indoor–Outdoor S20N11S03SS 2 5 — — EP 115 FR177 3A 113 (51) Indoor–Outdoor S20N11S05SS 2 7.5 — — EP 115 FR178 3A 123 (56) Indoor–Outdoor S20N11S07SS 10 — — EP 115 FR179 3A 193 (88) Indoor–Outdoor S20N11S10SS 15 — — EP 115 FR180 3A 205 (93) Indoor–Outdoor S20N11S15SS 25 — — EP 115 FR182 3A 375 (170) Indoor–Outdoor S20N11S25SS 2 2 2 2 Full Capacity Taps Notes 1 Refer to your local Eaton sales office. 2 NEMA 3R, 304 stainless steel enclosure; 316 stainless steel enclosure available as an option. Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 V2-T2-96 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.4 Transformers General-Purpose Encapsulated Transformers Single-Phase Encapsulated—Type EP, 60 Hz 2 2 480 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 1 — 2 at –5% EP 115 FR67P 2D 31 (14) Indoor–Outdoor S48G11P01P 1.5 — 2 at –5% EP 115 FR67P 2D 42 (19) Indoor–Outdoor S48G11P16P 2 — 2 at –5% EP 115 FR68P 2D 42 (19) Indoor–Outdoor S48G11P02P 3 — 2 at –5% EP 115 FR176 2D 65 (30) Indoor–Outdoor S48G11S03N 3 2 at +2.5% 2 at –2.5% EP 115 FR176 16A 65 (30) Indoor–Outdoor S48D11S03N 5 — 2 at –5% EP 115 FR177 2D 113 (51) Indoor–Outdoor S48G11S05N 5 2 at +2.5% 2 at –2.5% EP 115 FR177 16A 113 (51) Indoor–Outdoor S48D11S05N 7.5 — 2 at –5% EP 115 FR178 2D 123 (56) Indoor–Outdoor S48G11S07N 7.5 2 at +2.5% 2 at –2.5% EP 115 FR178 16A 123 (56) Indoor–Outdoor S48D11S07N 10 — 2 at –5% EP 115 FR179 2D 193 (88) Indoor–Outdoor S48G11S10N 10 2 at +2.5% 2 at –2.5% EP 115 FR179 16A 193 (88) Indoor–Outdoor S48D11S10N 15 — 2 at –5% EP 115 FR180 2D 216 (98) Indoor–Outdoor S48G11S15N 15 2 at +2.5% 2 at –2.5% EP 115 FR180 16A 216 (98) Indoor–Outdoor S48D11S15N 25 — 2 at –5% EP 115 FR182 2D 385 (175) Indoor–Outdoor S48G11S25N 25 2 at +2.5% 4 at –2.5% EP 115 FR132 83A 410 (186) Indoor–Outdoor S48M11S25N 2 2 2 2 2 2 2 2 2 2 2 480 Volts to 120/240 Volts Stainless Steel, Copper Windings 1 Full Capacity Taps 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 10 2 at +2.5% 2 at –2.5% EP 115 FR179 16A 210 (95) Indoor–Outdoor S48D11S10CUSS 15 2 at +2.5% 2 at –2.5% EP 115 FR180 16A 235 (107) Indoor–Outdoor S48D11S15SSCU 25 2 at +2.5% 4 at –2.5% EP 115 FR182 83A 415 (188) Indoor–Outdoor S48M11S25SSCU 2 2 2 2 600 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise 0.5 — 2 at –5% EP 115 Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number FR57P 2I 16 (7) Indoor–Outdoor S60G11P51P 0.75 — 2 at –5% EP 115 FR58AP 2I 26 (12) Indoor–Outdoor S60G11P76P 1 — 2 at –5% EP 115 FR67P 2I 31 (14) Indoor–Outdoor S60G11P01P 1.5 — 2 at –5% EP 115 FR67P 2I 42 (19) Indoor–Outdoor S60G11P16P 2 — 2 at –5% EP 115 FR68P 2I 42 (19) Indoor–Outdoor S60G11P02P 3 — 2 at –5% EP 115 FR176 2I 65 (30) Indoor–Outdoor S60G11S03N 5 — 2 at –5% EP 115 FR177 2I 105 (48) Indoor–Outdoor S60G11S05N 7.5 — 2 at –5% EP 115 FR178 2I 123 (56) Indoor–Outdoor S60G11S07N 10 — 2 at –5% EP 115 FR179 2I 193 (88) Indoor–Outdoor S60G11S10N 15 — 4 at –2.5% EP 115 FR180 527A 216 (98) Indoor–Outdoor S60J11S15N 25 — 4 at –2.5% EP 115 FR182 527A 385 (175) Indoor–Outdoor S60J11S25N 25 2 at +2.5% 4 at –2.5% EP 115 FR132 83B 395 (180) Indoor–Outdoor S60M11S25N 2 2 2 2 2 2 2 2 Notes 1 NEMA 3R, 304 stainless steel enclosure; 316 stainless steel enclosure available as an option. 2 Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-97 2.4 2 Transformers General-Purpose Encapsulated Transformers Single-Phase Shielded—Type EP, 60 Hz 2 120 x 240 Volts to 120/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — — EP 115 FR176 90B 50 (23) Indoor–Outdoor S10N11E03N S10N11E05N 2 2 2 2 Full Capacity Taps 5 — — EP 115 FR177 90B 90 (41) Indoor–Outdoor 7.5 — — EP 115 FR178 90B 123 (56) Indoor–Outdoor S10N11E07N 10 — — EP 115 FR179 90B 210 (95) Indoor–Outdoor S10N11E10N 15 — — EP 115 FR180 90B 205 (93) Indoor–Outdoor S10N11E15N 25 — — EP 115 FR182 90B 375 (170) Indoor–Outdoor S10N11E25N 2 120 Volts to 120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — — EP 115 FR176 77A 60 (27) Indoor–Outdoor S12N12E03N 2 5 — — EP 115 FR177 77A 100 (45) Indoor–Outdoor S12N12E05N 7.5 — — EP 115 FR178 77A 123 (56) Indoor–Outdoor S12N12E07N 2 10 — — EP 115 FR179 77A 180 (82) Indoor–Outdoor S12N12E10N 15 — — EP 115 FR180 77A 216 (98) Indoor–Outdoor S12N12E15N 25 — — EP 115 FR182 77A 375 (170) Indoor–Outdoor S12N12E25N 2 2 2 2 2 Full Capacity Taps 208 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — — EP 115 FR176 578A 60 (27) Indoor–Outdoor S29N11E03N 2 5 — — EP 115 FR177 578A 135 (61) Indoor–Outdoor S29N11E05N 7.5 — — EP 115 FR178 578A 95 (43) Indoor–Outdoor S29N11E07N 2 10 — — EP 115 FR179 578A 165 (75) Indoor–Outdoor S29N11E10N 15 — — EP 115 FR180 578A 185 (94) Indoor–Outdoor S29N11E15N 25 — — EP 115 FR182 578A 375 (170) Indoor–Outdoor S29N11E25N 2 2 2 2 2 2 2 2 2 208 Volts to 208 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — — EP 115 FR176 77B 65 (30) Indoor–Outdoor S29N29E03N 5 — — EP 115 FR177 77B 113 (51) Indoor–Outdoor S29N29E05N 7.5 — — EP 115 FR178 77B 123 (56) Indoor–Outdoor S29N29E07N 10 — — EP 115 FR179 77B 195 (89) Indoor–Outdoor S29N29E10N 15 — — EP 115 FR180 77B 216 (98) Indoor–Outdoor S29N29E15N 25 — — EP 115 FR182 77B 375 (170) Indoor–Outdoor S29N29E25N Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 V2-T2-98 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.4 Transformers General-Purpose Encapsulated Transformers Single-Phase Shielded—Type EP, 60 Hz 2 2 240 Volts to 240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 2 Catalog Number 3 — — EP 115 FR176 77C 65 (30) Indoor–Outdoor S24N24E03N 5 — — EP 115 FR177 77C 113 (51) Indoor–Outdoor S24N24E05N 7.5 — — EP 115 FR178 77C 123 (56) Indoor–Outdoor S24N24E07N 10 — — EP 115 FR179 77C 193 (88) Indoor–Outdoor S24N24E10N 15 — — EP 115 FR180 77C 216 (98) Indoor–Outdoor S24N24E15N 25 — — EP 115 FR182 77C 375 (170) Indoor–Outdoor S24N24E25N 2 2 2 2 2 277 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — — EP 115 FR176 513B 65 (30) Indoor–Outdoor S27N11E03N 5 — — EP 115 FR177 513B 113 (51) Indoor–Outdoor S27N11E05N 7.5 — — EP 115 FR178 513B 75 (34) Indoor–Outdoor S27N11E07N 10 — — EP 115 FR179 513B 162 (74) Indoor–Outdoor S27N11E10N 15 — — EP 115 FR180 513B 216 (98) Indoor–Outdoor S27N11E15N 25 — — EP 115 FR182 513B 375 (170) Indoor–Outdoor S27N11E25N 2 2 2 2 2 2 240 x 480 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 0.25 — — EP 115 FR57P 90A 12 (5) Indoor–Outdoor S20N11E26P 0.50 — — EP 115 FR57P 90A 16 (7) Indoor–Outdoor S20N11E51P 0.75 — — EP 115 FR58AP 90A 26 (12) Indoor–Outdoor S20N11E76P 1 — — EP 115 FR67P 90A 31 (14) Indoor–Outdoor S20N11E01P 1.5 — — EP 115 FR67P 90A 42 (19) Indoor–Outdoor S20N11E16P 2 — — EP 115 FR68P 90A 42 (19) Indoor–Outdoor S20N11E02P 3 — — EP 115 FR176 90A 65 (30) Indoor–Outdoor S20N11E03A 5 — — EP 115 FR177 90A 113 (51) Indoor–Outdoor S20N11E05A 7.5 — — EP 115 FR178 90A 123 (56) Indoor–Outdoor S20N11E07A 10 — — EP 115 FR179 90A 166 (75) Indoor–Outdoor S20N11E10A 15 — — EP 115 FR180 90A 216 (98) Indoor–Outdoor S20N11E15A 25 1 1 EP 115 FR182 526A 375 (170) Indoor–Outdoor S20L11E25A 2 2 2 2 2 2 2 2 2 Notes 1 2 at +5% FCBN at 240 volts; 4 at –2.5% FCBN at 480 volts. Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-99 2.4 2 Transformers General-Purpose Encapsulated Transformers Three-Phase Encapsulated—Type EPT, 60 Hz 2 240 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 9 — 2 at –5% EPT 115 FR103 70C 190 (86) Indoor–Outdoor Y24G28T09N 1 15 — 2 at –5% EPT 115 FR95 70C 275 (125) Indoor–Outdoor Y24G28T15N 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84C 422 (191) Indoor–Outdoor Y24M28T30N 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84C 660 (299) Indoor–Outdoor Y24M28T45N 2 2 2 Full Capacity Taps Catalog Number 2 380 Delta Volts to 190Y/110 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 3 — 2 at –5% EPT 115 FR201 70F 116 (53) Indoor–Outdoor Y38G19T03A 1 2 6 — 2 at –5% EPT 115 FR200 70F 165 (75) Indoor–Outdoor Y38G19T06A 1 9 — 2 at –5% EPT 115 FR95 70F 275 (125) Indoor–Outdoor Y38G19T09A 1 2 15 — 2 at –5% EPT 115 FR95 72R 275 (125) Indoor–Outdoor Y38G19T15A 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84AC 422 (191) Indoor–Outdoor Y38M19T30A 2 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84AC 660 (299) Indoor–Outdoor Y38M19T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84AC 1275 (580) Indoor–Outdoor Y38M19T75A 2 Catalog Number Full Capacity Taps 2 2 380 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 2 3 — 2 at –5% EPT 115 FR201 70D 116 (53) Indoor–Outdoor Y38G28T03A 1 6 — 2 at –5% EPT 115 FR200 70F 165 (75) Indoor–Outdoor Y38G28T06A 1 2 9 — 2 at –5% EPT 115 FR103 70D 185 (84) Indoor–Outdoor Y38G28T09A 1 15 — 2 at –5% EPT 115 FR95 70D 275 (125) Indoor–Outdoor Y38G28T15A 1 2 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84H 422 (191) Indoor–Outdoor Y38M28T30A 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84R 660 (299) Indoor–Outdoor Y38M28T45A 2 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84R 1275 (580) Indoor–Outdoor Y38M28T75A 2 2 Notes 1 T-T (Scott T) connected secondary. 2 Floor-mount only. 2 Full Capacity Taps Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-100 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.4 Transformers General-Purpose Encapsulated Transformers Three-Phase Encapsulated—Type EPT, 60 Hz 2 2 380 Delta Volts to 220Y/127 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 2 Catalog Number 3 — 2 at –5% EPT 115 FR201 70F 116 (53) Indoor–Outdoor Y38G31T03A 1 6 — 2 at –5% EPT 115 FR200 70F 165 (75) Indoor–Outdoor Y38G31T06A 1 9 — 2 at –5% EPT 115 FR103 70M 195 (89) Indoor–Outdoor Y38G31T09A 1 15 — 2 at –5% EPT 115 FR95 70F 275 (125) Indoor–Outdoor Y38G31T15A 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84R 422 (191) Indoor–Outdoor Y38M31T30A 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84R 660 (299) Indoor–Outdoor Y38M31T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84R 1275 (580) Indoor–Outdoor Y38M31T75A 2 2 2 2 2 2 2 380 Delta Volts to 220 Delta Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — 2 at –5% EPT 115 FR201 74K 116 (53) Indoor–Outdoor Y38G25T03A 1 6 — 2 at –5% EPT 115 FR200 74K 180 (82) Indoor–Outdoor Y38G25T06A 1 9 — 2 at –5% EPT 115 FR103 74K 195 (89) Indoor–Outdoor Y38G25T09A 1 15 — 2 at –5% EPT 115 FR95 74K 275 (125) Indoor–Outdoor Y38G25T15A 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 3 422 (191) Indoor–Outdoor Y38M25T30A 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 3 660 (299) Indoor–Outdoor Y38M25T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 3 1275 (580) Indoor–Outdoor Y38M25T75A 2 2 2 2 2 2 380 Delta Volts to 380Y/220 Volts Full Capacity Taps 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — 2 at –5% EPT 115 FR201 70D 116 (53) Indoor–Outdoor Y38G37T03A 1 6 — 2 at –5% EPT 115 FR200 70D 165 (75) Indoor–Outdoor Y38G37T06A 1 9 — 2 at –5% EPT 115 FR103 70D 180 (82) Indoor–Outdoor Y38G37T09A 1 15 — 2 at –5% EPT 115 FR95 70D 275 (125) Indoor–Outdoor Y38G37T15A 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84H 422 (191) Indoor–Outdoor Y38M37T30A 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84H 660 (299) Indoor–Outdoor Y38M37T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84H 1275 (580) Indoor–Outdoor Y38M37T75A 2 kVA FCAN FCBN Type 2 2 2 2 2 2 380 Delta Volts to 480Y/277 Volts Full Capacity Taps 2 ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — 2 at –5% EPT 115 FR201 70F 116 (53) Indoor–Outdoor Y38G47T03A 1 6 — 2 at –5% EPT 115 FR200 70F 180 (82) Indoor–Outdoor Y38G47T06A 1 9 — 2 at –5% EPT 115 FR103 70F 166 (75) Indoor–Outdoor Y38G47T09A 1 15 — 2 at –5% EPT 115 FR95 70F 275 (125) Indoor–Outdoor Y38G47T15A 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84AB 422 (191) Indoor–Outdoor Y38M47T30A 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84AB 660 (299) Indoor–Outdoor Y38M47T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84AB 1275 (580) Indoor–Outdoor Y38M47T75A 2 2 2 2 2 2 2 Notes 1 T-T (Scott T) connected secondary. 2 Floor-mount only. 3 Refer to your Eaton sales office. 2 Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-101 2 2.4 2 Transformers General-Purpose Encapsulated Transformers Three-Phase Encapsulated—Type EPT, 60 Hz 2 416 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 3 — 2 at –5% EPT 115 FR201 70V 116 (53) Indoor–Outdoor Y43G28T03A 1 6 — 2 at –5% EPT 115 FR200 70V 175 (79) Indoor–Outdoor Y43G28T06A 1 9 — 2 at –5% EPT 115 FR103 70V 190 (86) Indoor–Outdoor Y43G28T09A 1 15 — 2 at –5% EPT 115 FR95 70V 275 (125) Indoor–Outdoor Y43G28T15A 1 2 2 2 2 2 2 Full Capacity Taps Catalog Number 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84I 422 (191) Indoor–Outdoor Y43M28T30A 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84I 660 (299) Indoor–Outdoor Y43M28T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84I 1275 (580) Indoor–Outdoor Y43M28T75A 2 440 Delta Volts to 220Y/127 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — 2 at –5% EPT 115 FR201 70G 116 (53) Indoor–Outdoor Y44G31T03A 1 2 6 — 2 at –5% EPT 115 FR200 70G 165 (75) Indoor–Outdoor Y44G31T06A 1 9 — 2 at –5% EPT 115 FR103 70G 166 (75) Indoor–Outdoor Y44G31T09A 1 2 15 — 2 at –5% EPT 115 FR95 70G 275 (125) Indoor–Outdoor Y44G31T15A 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84O 422 (191) Indoor–Outdoor Y44M31T30A 2 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84O 660 (299) Indoor–Outdoor Y44M31T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84O 1275 (580) Indoor–Outdoor Y44M31T75A 2 2 2 2 2 480 Delta Volts to 208Y/120 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 3 — 2 at –5% EPT 115 FR201 70A 116 (52) Indoor–Outdoor Y48G28T03N 1 6 — 2 at –5% EPT 115 FR200 70A 165 (75) Indoor–Outdoor Y48G28T06N 1 2 6 2 at +2.5% 2 at –2.5% EPT 115 FR200 72B 165 (75) Indoor–Outdoor Y48D28T06N 1 9 — 2 at –5% EPT 115 FR103 70A 166 (75) Indoor–Outdoor Y48G28T09N 1 2 9 — 4 at –2.5% EPT 115 FR103 503A 185 (84) Indoor–Outdoor Y48J28T09N 1 9 2 at +2.5% 2 at –2.5% EPT 115 FR103 72B 185 (84) Indoor–Outdoor Y48D28T09N 1 2 15 — 2 at –5% EPT 115 FR95 70A 275 (125) Indoor–Outdoor Y48G28T15N 1 2 15 — 4 at –2.5% EPT 115 FR95 503A 275 (125) Indoor–Outdoor Y48J28T15N 1 15 2 at +2.5% 2 at –2.5% EPT 115 FR95 72B 275 (125) Indoor–Outdoor Y48D28T15N 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84A 422 (191) Indoor–Outdoor Y48M28T30N 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84A 720 (327) Indoor–Outdoor Y48M28T45N 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84A 1275 (580) Indoor–Outdoor Y48M28T75N 2 Catalog Number 2 2 Full Capacity Taps 2 480 Delta Volts to 208Y/120 Volts—Copper Windings 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 15 2 at +2.5% 2 at –2.5% EPT 115 FR95 72B 300 (136) Indoor–Outdoor Y48D28T15CU 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84A 505 (230) Indoor–Outdoor Y48M28T30CU 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84A 810 (368) Indoor–Outdoor Y48M28T45CU 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84A 1450 (659) Indoor–Outdoor Y48M28T75CU 23 2 2 2 2 2 Full Capacity Taps Notes 1 T-T (Scott T) connected secondary. 2 Floor-mount only. 3 Not CSA certified. Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. V2-T2-102 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.4 Transformers General-Purpose Encapsulated Transformers Three-Phase Encapsulated—Type EPT, 60 Hz 2 2 480 Delta Volts to 208Y/120 Volts Stainless Steel 1 Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number 3 — 2 at –5% EPT 115 FR201 70A 6 2 at +2.5% 2 at –2.5% EPT 115 FR200 72B Weight Lbs (kg) Weathershield Catalog Number 116 (53) Indoor–Outdoor Y48G28T03SS 2 175 (79) Indoor–Outdoor Y48D28T06SS 2 9 2 at +2.5% 2 at –2.5% EPT 115 FR103 72B 185 (84) Indoor–Outdoor Y48D28T09SS 2 15 2 at +2.5% 2 at –2.5% EPT 115 FR95 72B 275 (125) Indoor–Outdoor Y48D28T15SS 2 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84A 422 (191) Indoor–Outdoor Y48M28T30SS 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84A 660 (299) Indoor–Outdoor Y48M28T45SS 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84A 1275 (580) Indoor–Outdoor Y48M28T75SS 3 2 2 2 2 2 2 2 480 Delta Volts to 208Y/120 Volts Stainless Steel—Copper Windings 1 Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 2 at –2.5% EPT 115 FR95 72B 275 (125) Indoor–Outdoor Y48D28T15CUSS 2 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84A 504 (229) Indoor–Outdoor Y48M28T30CUSS 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84A 810 (368) Indoor–Outdoor Y48M28T45CUSS 2 2 2 480 Delta Volts to 220Y/127 Volts Full Capacity Taps 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — 2 at –5% EPT 115 FR201 70K 116 (53) Indoor–Outdoor Y48G31T03A 2 6 — 2 at –5% EPT 115 FR200 70K 175 (79) Indoor–Outdoor Y48G31T06A 2 9 — 2 at –5% EPT 115 FR103 70A 185 (84) Indoor–Outdoor Y48G31T09A 2 15 — 2 at –5% EPT 115 FR95 70A 275 (125) Indoor–Outdoor Y48G31T15A 2 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84A 422 (191) Indoor–Outdoor Y48M31T30A 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84A 660 (299) Indoor–Outdoor Y48M31T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84K 1275 (580) Indoor–Outdoor Y48M31T75A 3 2 2 2 2 2 2 2 480 Delta Volts to 240 Delta Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — 2 at –5% EPT 115 FR201 74A 116 (52) Indoor–Outdoor Y48G24T03N 24 6 — 2 at –5% EPT 115 FR200 74A 165 (75) Indoor–Outdoor Y48G24T06N 24 9 — 4 at –2.5% EPT 115 FR103 73A 185 (84) Indoor–Outdoor Y48J24T09N 24 15 — 4 at –2.5% EPT 115 FR95 73A 275 (125) Indoor–Outdoor Y48J24T15N 24 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 85A 422 (191) Indoor–Outdoor Y48M24T30N 4 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 85A 660 (299) Indoor–Outdoor Y48M24T45N 4 2 2 2 2 2 Notes 1 NEMA 3R, 304 stainless steel enclosure; 316 stainless steel enclosure available. 2 T-T connected secondary. 3 Floor-mount only. 4 Do not include 120 volt lighting tap. 2 Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-103 2.4 2 Transformers General-Purpose Encapsulated Transformers Three-Phase Encapsulated—Type EPT, 60 Hz 2 480 Delta Volts to 380Y/220 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 3 — 2 at –5% EPT 115 FR201 70A 116 (53) Indoor–Outdoor Y48G37T03A 1 6 — 2 at –5% EPT 115 FR200 70R 165 (75) Indoor–Outdoor Y48G37T06A 1 Y48G37T09A 1 2 2 2 2 Full Capacity Taps Catalog Number 9 — 2 at –5% EPT 115 FR103 70R 185 (84) Indoor–Outdoor 15 — 2 at –5% EPT 115 FR95 70R 275 (125) Indoor–Outdoor Y48G37T15A 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84A 422 (191) Indoor–Outdoor Y48M37T30A 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84A 660 (299) Indoor–Outdoor Y48M37T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84A 1275 (580) Indoor–Outdoor Y48M37T75A 2 2 2 480 Delta Volts to 380 Delta Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — 2 at –5% EPT 115 FR201 74B 116 (53) Indoor–Outdoor Y48G38T03A 1 6 — 2 at –5% EPT 115 FR200 74B 165 (75) Indoor–Outdoor Y48G38T06A 1 2 9 — 2 at –5% EPT 115 FR103 74B 185 (84) Indoor–Outdoor Y48G38T09A 1 15 — 2 at –5% EPT 115 FR95 74A 275 (125) Indoor–Outdoor Y48G38T15A 1 2 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 85A 422 (191) Indoor–Outdoor Y48M38T30A 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 85A 660 (299) Indoor–Outdoor Y48M38T45A 2 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 85A 1275 (580) Indoor–Outdoor Y48M38T75A 2 2 Full Capacity Taps 2 480 Delta Volts to 416Y/240 Volts 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — 2 at –5% EPT 115 FR200 70A 165 (75) Indoor–Outdoor Y48G51T03A 1 6 — 2 at –5% EPT 115 FR200 70A 185 (84) Indoor–Outdoor Y48G51T06A 1 9 — 2 at –5% EPT 115 FR103 70S 185 (84) Indoor–Outdoor Y48G51T09A 1 15 — 2 at –5% EPT 115 FR95 70S 275 (125) Indoor–Outdoor Y48G51T15A 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84A 422 (191) Indoor–Outdoor Y48M51T30A 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84A 660 (299) Indoor–Outdoor Y48M51T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84A 1275 (580) Indoor–Outdoor Y48M51T75A 2 2 2 2 2 2 2 Full Capacity Taps 480 Delta Volts to 440Y/254 Volts Full Capacity Taps 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — 2 at –5% EPT 115 FR201 70A 116 (53) Indoor–Outdoor Y48G35T03A 1 2 6 — 2 at –5% EPT 115 FR200 70A 185 (84) Indoor–Outdoor Y48G35T06A 1 9 — 2 at –5% EPT 115 FR103 70A 185 (84) Indoor–Outdoor Y48G35T09A 1 2 15 — 2 at –5% EPT 115 FR95 70A 275 (125) Indoor–Outdoor Y48G35T15A 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84A 422 (191) Indoor–Outdoor Y48M35T30A 2 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84A 660 (299) Indoor–Outdoor Y48M35T45A 75 2 at +2.5% 4 at –2.5% EPT 115 FR245 84A 1275 (580) Indoor–Outdoor Y48M35T75A 2 2 2 2 Notes 1 T-T connected secondary. 2 Floor-mount only. Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 V2-T2-104 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.4 Transformers General-Purpose Encapsulated Transformers Three-Phase Encapsulated—Type EPT, 60 Hz 2 2 480 Delta Volts to 480Y/277 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 9 2 at +2.5% 2 at –2.5% EPT 115 FR103 72C 190 (86) Indoor–Outdoor Y48D47T09N 1 15 2 at +2.5% 2 at –2.5% EPT 115 FR95 72C 275 (125) Indoor–Outdoor Y48D47T15N 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84A 422 (191) Indoor–Outdoor Y48M47T30N 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84A 660 (299) Indoor–Outdoor Y48M47T45N 2 2 2 2 600 Delta Volts to 208Y/120 Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 9 — 2 at –5% EPT 115 FR103 70B 185 (84) Indoor–Outdoor Y60G28T09N 1 15 — 2 at –5% EPT 115 FR95 70B 275 (125) Indoor–Outdoor Y60G28T15N 1 30 2 at +2.5% 4 at –2.5% EPT 115 FR243 84B 422 (191) Indoor–Outdoor Y60M28T30N 45 2 at +2.5% 4 at –2.5% EPT 115 FR244 84B 660 (299) Indoor–Outdoor Y60M28T45N 2 2 2 2 2 Three-Phase Shielded—Type EPT, 60 Hz 2 2 480 Delta Volts to 208Y/120 Volts Full Capacity Taps 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 2 at +2.5% 2 at –2.5% EPT 115 FR201 86B 116 (52) Indoor–Outdoor Y48D28E03A 1 6 2 at +2.5% 2 at –2.5% EPT 115 FR200 86B 165 (75) Indoor–Outdoor Y48D28E06A 1 9 2 at +2.5% 2 at –2.5% EPT 115 FR103 86B 190 (86) Indoor–Outdoor Y48D28E09N 1 15 2 at +2.5% 2 at –2.5% EPT 115 FR95 86B 275 (125) Indoor–Outdoor Y48D28E15B 1 2 2 2 2 2 480 Delta Volts to 240 Delta Volts Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 — 2 at –5% EPT 115 FR201 88A 116 (52) Indoor–Outdoor Y48G24E03A 1 6 — 2 at –5% EPT 115 FR200 88A 165 (75) Indoor–Outdoor Y48G24E06A 1 9 — 4 at –2.5% EPT 115 FR103 505B 195 (89) Indoor–Outdoor Y48J24E09A 1 15 — 4 at –2.5% EPT 115 FR95 505B 275 (125) Indoor–Outdoor Y48J24E15A 1 2 2 2 2 Notes 1 T-T connected secondary. Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-105 2.4 2 Transformers General-Purpose Encapsulated Transformers NEMA Type 4X Single-Phase Encapsulated—Type EP, 60 Hz, Grade 304 Stainless Steel 1 2 240 x 480 Volts to 120/240 Volts—Aluminum Windings 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 0.100 2 — — EP 115 FR544X 3A 7 (3) Indoor–Outdoor S20N11S82SS4X 2 0.015 2 — — EP 115 FR554X 3A 9 (4) Indoor–Outdoor S20N11S83SS4X 0.250 2 — — EP 115 FR57P4X 3A 15 (7) Indoor–Outdoor S20N11P26SS4X 2 0.500 2 — — EP 115 FR57P4X 3A 14 (6) Indoor–Outdoor S20N11P51SS4X 0.750 2 — — EP 115 FR58AP4X 3A 22 (10 ) Indoor–Outdoor S20N11P76SS4X 2 12 — — EP 115 FR67P4X 3A 30 (14) Indoor–Outdoor S20N11P01SS4X 1.5 2 — — EP 115 FR67P4X 3A 41 (19) Indoor–Outdoor S20N11P16SS4X 2 22 — — EP 115 FR68P4X 3A 75 (34) Indoor–Outdoor S20N11P02SS4X 2 3 — — EP 115 FR1764X 3A 68 (31) Indoor–Outdoor S20N11S03SS4X 3 3 3 EP 115 FR1764X 9A 67 (30) Indoor–Outdoor S20K11S03SS4X 5 — — EP 115 FR1774X 3A 107 (49) Indoor–Outdoor S20N11S05SS4X 5 3 3 EP 115 FR1774X 9A 105 (48) Indoor–Outdoor S20K11S05SS4X 2 7.5 — — EP 115 FR1784X 3A 129 (58) Indoor–Outdoor S20N11S07SS4X 3 3 2 7.5 EP 115 FR1784X 9A 130 (59) Indoor–Outdoor S20K11S07SS4X 10 — — EP 115 FR1794X 3A 196 (89) Indoor–Outdoor S20N11S10SS4X 2 10 3 3 EP 115 FR1794X 9A 198 (90) Indoor–Outdoor S20K11S10SS4X 15 — — EP 115 FR1804X 3A 215 (98) Indoor–Outdoor S20N11S15SS4X 2 15 3 3 EP 115 FR1804X 23A 215 (98) Indoor–Outdoor S20L11S15SS4X 25 — — EP 115 FR1824X 3A 393 (178) Indoor–Outdoor S20N11S25SS4X 25 4 4 EP 115 FR1824X 23A 453 (206) Indoor–Outdoor S20L11S25SS4X 37.5 4 4 EP 115 FR300A4X 248A 735 (334) Indoor–Outdoor S20L11S37SS4X 5 2 2 2 2 2 2 Full Capacity Taps Notes 1 Grade 304 stainless steel standard. Grade 316 stainless steel available as an option. Replace suffix “SS” with suffix “S6.” 2 Copper windings provided as standard. 3 1 at +10% FCBN at 240 volts; 2 at –5% FCBN at 480 volts. 4 2 at +5% FCBN at 240 volts; 4 at –2.5% FCBN at 480 volts. 5 Floor-mount only. Contact your local Eaton sales office for voltage combinations not shown in the above table. Other voltages and custom features are available upon request. 2 2 2 2 2 2 2 2 2 2 2 V2-T2-106 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.4 Transformers General-Purpose Encapsulated Transformers NEMA Type 4X Single-Phase Encapsulated—Type EP, 60 Hz, Grade 304 Stainless Steel 1 2 2 240 x 480 Volts to 120/240 Volts—Copper Windings Full Capacity Taps kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 0.100 2 — — EP 115 FR544X 3A 7 (3) Indoor–Outdoor S20N11S82SS4X 0.015 2 — — EP 115 FR554X 3A 9 (4) Indoor–Outdoor S20N11S83SS4X 0.250 2 — — EP 115 FR57P4X 3A 15 (7) Indoor–Outdoor S20N11P26SS4X 0.500 2 — — EP 115 FR57P4X 3A 14 (6) Indoor–Outdoor S20N11P51SS4X 0.750 2 — — EP 115 FR58AP4X 3A 22 (10) Indoor–Outdoor S20N11P76SS4X 12 — — EP 115 FR67P4X 3A 30 (14) Indoor–Outdoor S20N11P01SS4X 1.5 2 — — EP 115 FR68P4X 3A 41 (19) Indoor–Outdoor S20N11P02SS4X 2 2 2 2 2 22 — — EP 115 FR68P4X 3A 36 (16) Indoor–Outdoor S20N11P16SS4X 3 — — EP 115 FR1764X 3A 76 (34) Indoor–Outdoor S20N11S03CUSS4X 3 3 3 EP 115 FR1764X 9A 77 (35) Indoor–Outdoor S20K11S03CUSS4X 5 — — EP 115 FR1774X 3A 135 (61) Indoor–Outdoor S20N11S05CUSS4X 5 3 3 EP 115 FR1774X 9A 121 (55) Indoor–Outdoor S20K11S05CUSS4X 7.5 — — EP 115 FR1784X 3A 144 (65) Indoor–Outdoor S20N11S07CUSS4X 7.5 3 3 EP 115 FR1784X 9A 146 (66) Indoor–Outdoor S20K11S07CUSS4X 10 — — EP 115 FR1794X 3A 229 (104) Indoor–Outdoor S20N11S10CUSS4X 10 3 3 EP 115 FR1794X 9A 219 (99) Indoor–Outdoor S20K11S10CUSS4X 15 — — EP 115 FR1804X 3A 236 (107) Indoor–Outdoor S20N11S15CUSS4X 15 3 3 EP 115 FR1804X 23A 236 (107) Indoor–Outdoor S20L11S15CUSS4X 25 — — EP 115 FR300A4X 3A 388 (176) Indoor–Outdoor S20N11S25CUSS4X 25 4 4 EP 115 FR300A4X 23A 388 (176) Indoor–Outdoor S20L11S25CUSS4X 37.5 4 4 EP 115 FR300A4X 248A 775 (352) Indoor–Outdoor S20L11S37CUSS4X 5 Notes 1 Grade 304 stainless steel standard. Grade 316 stainless steel available as an option. Replace suffix “SS” with suffix “S6.” 2 Copper windings provided as standard. 3 1 at +10% FCBN at 240 volts; 2 at –5% FCBN at 480 volts. 4 2 at +5% FCBN at 240 volts; 4 at –2.5% FCBN at 480 volts. 5 Floor-mount only. 2 2 2 2 2 2 2 2 2 2 2 2 Contact your local Eaton sales office for voltage combinations not shown in the above table. Other voltages and custom features are available upon request. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-107 2.4 2 Transformers General-Purpose Encapsulated Transformers NEMA Type 4X Three-Phase Encapsulated—Type EPT, 60 Hz, Grade 304 Stainless Steel 1 2 480 Delta Volts to 208Y/120 Volts—Aluminum Windings 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 3 — 2 at –5% EPT 115 FR2014X 70A 125 (57) Indoor–Outdoor Y48G28T03SS4X 2 6 — 2 at –5% EPT 115 FR2004X 70A 165 (75) Indoor–Outdoor Y48G28T06SS4X 2 6 2 at +2.5% 2 at –2.5% EPT 115 FR2004X 72B 171 (78) Indoor–Outdoor Y48D28T06SS4X 2 2 9 — 2 at –5% EPT 115 FR1034X 70A 180 (82) Indoor–Outdoor Y48G28T09SS4X 2 9 — 4 at –2.5% EPT 115 FR1034X 503A 192 (87) Indoor–Outdoor Y48J28T09SS4X 2 2 9 2 at +2.5% 2 at –2.5% EPT 115 FR1034X 72B 196 (89) Indoor–Outdoor Y48D28T09SS4X 2 15 2 at +2.5% 2 at –2.5% EPT 115 FR954X 72B 281 (127) Indoor–Outdoor Y48D28T15SS4X 2 2 15 — 2 at –5% EPT 115 FR954X 70A 269 (122) Indoor–Outdoor Y48G28T15SS4X 2 2 15 — 4 at –2.5% EPT 115 FR954X 503A 268 (121) Indoor–Outdoor Y48J28T15SS4X 2 30 2 at +2.5% 4 at –2.5% EPT 115 FR2434X 84A 539 (245) Indoor–Outdoor Y48M28T30SS4X 45 2 at +2.5% 4 at –2.5% EPT 115 FR2444X 84A 723 (328) Indoor–Outdoor Y48M28T45SS4X 75 2 at +2.5% 4 at –2.5% EPT 115 FR2454X 84A 1277 (580) Indoor–Outdoor Y48M28T75SS4X 3 Catalog Number 2 2 2 Full Capacity Taps Catalog Number 2 2 480 Delta Volts to 208Y/120 Volts—Copper Windings 2 kVA FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 2 3 — 2 at –5% EPT 115 FR2014X 70A 139 (63) Indoor–Outdoor Y48G28T03CUSS4X 2 6 — 2 at –5% EPT 115 FR2004X 70A 187 (84) Indoor–Outdoor Y48G28T06CUSS4X 2 2 6 2 at +2.5% 2 at –2.5% EPT 115 FR2004X 72B 188 (85) Indoor–Outdoor Y48D28T06CUSS4X 2 9 — 2 at –5% EPT 115 FR1034X 70A 226 (103) Indoor–Outdoor Y48G28T09CUSS4X 2 2 9 — 4 at –2.5% EPT 115 FR1034X 503A 226 (103) Indoor–Outdoor Y48J28T09CUSS4X 2 9 2 at +2.5% 2 at –2.5% EPT 115 FR1034X 72B 231 (105) Indoor–Outdoor Y48D28T09CUSS4X 2 2 15 2 at +2.5% 2 at –2.5% EPT 115 FR954X 72B 276 (125) Indoor–Outdoor Y48D28T15CUSS4X 2 2 15 — 2 at –5% EPT 115 FR954X 70A 283 (128) Indoor–Outdoor Y48G28T15CUSS4X 2 15 — 4 at –2.5% EPT 115 FR954X 503A 299 (136) Indoor–Outdoor Y48J28T15CUSS4X 2 2 30 2 at +2.5% 4 at –2.5% EPT 115 FR2434X 84A 602 (273) Indoor–Outdoor Y48M28T30CUSS4X 45 2 at +2.5% 4 at –2.5% EPT 115 FR2444X 84A 829 (376) Indoor–Outdoor Y48M28T45CUSS4X 2 75 2 at +2.5% 4 at –2.5% EPT 115 FR2454X 84A 1452 (659) Indoor–Outdoor Y48M28T75CUSS4X 3 2 2 Full Capacity Taps Notes 1 Grade 304 stainless steel standard. Grade 316 stainless steel available as an option. Replace suffix “SS” with suffix “S6.” 2 T-T connected (Scott T) secondary winding configuration. 3 Floor-mount only. Contact your local Eaton sales office for voltage combinations not shown in the above table. Other voltages and custom features are available upon request. 2 2 2 2 2 2 2 2 V2-T2-108 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.4 Transformers General-Purpose Encapsulated Transformers Accessories 2 Please refer to Section 2.7 Page V2-T2-191. 2 Technical Data and Specifications Frequency Enclosures Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Eaton encapsulated transformers, Types EP and EPT, use a NEMA 3R rated enclosure as standard. NEMA 4X enclosures (grade 304 or 316 stainless steel) are available as an option. Overload Capability Winding Terminations Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Ventilated transformers have leads brought out to aluminum pads that are predrilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. Eaton recommends that external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 40°C 80°C 30°C 150°C 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C 40°C 150°C 30°C 220°C The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. 2 Sound Levels All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. For additional information, please refer to Section 2.7 Page V2-T2-195. 2 2 2 2 2 2 Average Sound Levels NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) K-Factor 1, 4, 9 K-Factor 13, 20 kVA Range Encapsulated (up to 1.2 kV) 3.00 and below 45 40 2 40 2 2 2 3.01 to 9.00 40 40 45 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 Series-Multiple Windings 50.01 to 75.00 50 53 55 Series-multiple windings consist of two similar coils in each winding that can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with an “x” or “/” between the voltage ratings, such as voltages of “120/240” or “240 x 480.” If the series-multiple winding is designated by an “x,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 x 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), 240 (series) or 240 with a 120 mid-point. 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 500.01 to 700.00 62 65 61 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory 2 2 2 2 2 2 Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-109 2.5 Transformers Distribution Transformers Contents 2 Description 2 Distribution Transformers Motor Drive Isolation Transformers . . . . . . . . . Mini–Power Centers . . . . . . . . . . . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers . Class I, Division 2, Hazardous Location Transformers . . . . . . . . . . . . . . . . . . . . . . . . . Open-Type Core and Coil Assembly Transformers . . . . . . . . . . . . . . . . . . . . . . . . . Marine Duty Transformers . . . . . . . . . . . . . . . . Buck-Boost and Low Voltage Lighting Transformers . . . . . . . . . . . . . . . . . . . . . . . . . Medium Voltage Distribution Transformers . . . 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-110 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Page V2-T2-111 V2-T2-119 V2-T2-124 V2-T2-127 V2-T2-130 V2-T2-133 V2-T2-144 V2-T2-173 Transformers Distribution Transformers 2.5 Contents Type MD Description Page Motor Drive Isolation Transformers Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers. . . . Class I, Division 2, Hazardous Location Transformers Open-Type Core and Coil Assembly Transformers Marine Duty Transformers. . . . . . . . . . . . . . . . . . . Buck-Boost and Low Voltage Lighting Transformers Medium Voltage Distribution Transformers . . . . . . V2-T2-112 V2-T2-112 V2-T2-118 V2-T2-118 V2-T2-119 V2-T2-124 V2-T2-127 V2-T2-130 V2-T2-133 V2-T2-144 V2-T2-173 2 2 2 2 2 2 2 2 2 2 2 Motor Drive Isolation Transformers Product Description Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. ● ● ● ● ● Suitable for indoor or outdoor applications (with weathershield) Ventilated enclosures 220°C insulation system 150°C rise standard (self extinguishing), 115°C or 80°C rise optional Available in ratings from 7.5 through 1500 kVA Application Description Features, Benefits and Functions Drive isolation transformers are specifically designed for use with AC and DC adjustable speed drives. Two winding drive isolation transformers provide: ● ● ● ● ● Electrical isolation between the incoming line and the drive circuitry Voltage conversion of input line to standard drive input voltages Minimized line disturbances caused by SCR (silicon controlled rectifiers) firing Reduced short-circuit currents and voltage line transients Drive isolation transformers are specifically sized to the drive kVA requirements and are braced to withstand the mechanical stresses of current reversals and short circuits associated with SCR drives. ● ● ● ● ● ● ● 60 Hz operation (50/60 Hz operation available) Short-term overload capability as required by ANSI Primary and secondary terminals are front accessible for fast and easy connection Slotted screw mounting holes in enclosure and cover reduce installation time Sound dampening pads, which isolate the core and coil from the case, reduce noise levels to meet NEMA ST-20 Core laminations of precision sheared silicon steel are hand stacked to ensure quiet operation Terminations are clearly marked for easy identification Three-phase transformers have one 5% full capacity tap above and below nominal voltage for incoming source adjustment ● ● ● ● Units are suitable for continuous operation in a 40°C ambient maximum Full current neutral Thermoguard protection embedded in coils of threephase models to indicate that high temperatures (approximately 190°C) are present. Thermoguards consist of a set of NO dry contacts Three coil delta-wye configurations are used throughout the product line Standards and Certifications ● ● ● ● ANSI C89.2 NEMA ST-20 UL 506 UL 1561 2 2 2 2 2 2 2 2 2 2 2 2 2 Seismic Qualified All Eaton manufactured drytype distribution transformers are seismically qualified and exceed requirements of the International Building Code (IBC) and California Code Title 24. 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-111 2.5 2 2 Transformers Distribution Transformers Catalog Number Selection Please refer to Section 2.7 Page V2-T2-187. Product Selection 2 Additional Product Selection information begins on Page V2-T2-189. 2 Three-Phase Drive Isolation 2 208 Delta Volts to 460Y/266 Volts 2 hp kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 5 7.5 1 at +5% 1 at –5% 150 912D 347B 158 (72) WS38 MD075E86 7.5 11 1 at +5% 1 at –5% 150 912D 347B 176 (80) WS38 MD11E86 2 10 14 1 at +5% 1 at –5% 150 912D 347B 149 (68) WS38 MD14E86 2 15 20 1 at +5% 1 at –5% 150 912D 347B 240 (19) WS38 MD20E86 20 27 1 at +5% 1 at –5% 150 912D 347B 231 (15) WS38 MD27E86 2 25 34 1 at +5% 1 at –5% 150 912D 347B 310 (141) WS38 MD34E86 30 40 1 at +5% 1 at –5% 150 912D 347B 307 (139) WS38 MD40E86 2 40 51 1 at +5% 1 at –5% 150 914F 347B 480 (218) WS39 MD51E86 2 50 63 1 at +5% 1 at –5% 150 914F 347B 485 (220) WS39 MD63E86 60 75 1 at +5% 1 at –5% 150 914F 347B 482 (219) WS39 MD75E86 2 75 93 1 at +5% 1 at –5% 150 915F 347B 600 (272) WS39 MD93E86 100 118 1 at +5% 1 at –5% 150 916A 347B 658 (299) WS19 MD118E86 2 125 145 1 at +5% 1 at –5% 150 916A 347B 770 (350) WS19 MD145E86 150 175 1 at +5% 1 at –5% 150 918A 321B 1320 (599) WS34 MD175E86 2 200 220 1 at +5% 1 at –5% 150 918A 321B 1436 (652) WS34 MD220E86 2 250 275 1 at +5% 1 at –5% 150 918A 321B 1 WS34 MD275E86 300 330 1 at +5% 1 at –5% 150 919E 321B 1 WS35 MD330E86 400 440 1 at +5% 1 at –5% 150 920E 321B 1 WS35 MD440E86 2 2 2 Full Capacity Taps Notes 1 Contact Eaton. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-112 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Three-Phase Drive Isolation 2 2 230 Delta Volts to 230Y/133 Volts Full Capacity Taps hp kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 5 7.5 1 at +5% 1 at –5% 150 912D 286A 158 (72) WS38 MD075E88 7.5 11 1 at +5% 1 at –5% 150 912D 286A 156 (71) WS38 MD11E88 10 14 1 at +5% 1 at –5% 150 912D 286A 158 (72) WS38 MD14E88 15 20 1 at +5% 1 at –5% 150 912D 286A 216 (98) WS38 MD20E88 20 27 1 at +5% 1 at –5% 150 912D 286A 231 (105) WS38 MD27E88 25 34 1 at +5% 1 at –5% 150 912D 286A 310 (141) WS38 MD34E88 30 40 1 at +5% 1 at –5% 150 912D 286A 310 (141) WS38 MD40E88 40 51 1 at +5% 1 at –5% 150 914F 286A 480 (218) WS39 MD51E88 50 63 1 at +5% 1 at –5% 150 914F 286A 500 (227) WS39 MD63E88 60 75 1 at +5% 1 at –5% 150 914F 286A 538 (244) WS39 MD75E88 75 93 1 at +5% 1 at –5% 150 915F 286A 600 (272) WS39 MD93E88 100 118 1 at +5% 1 at –5% 150 915F 286A 600 (272) WS39 MD118E88 125 145 1 at +5% 1 at –5% 150 916A 286A 868 (394) WS19 MD145E88 150 175 1 at +5% 1 at –5% 150 918A 318D 1320 (599) WS34 MD175E88 200 220 1 at +5% 1 at –5% 150 918A 318D 1332 (605) WS34 MD220E88 250 275 1 at +5% 1 at –5% 150 918A 318D 1350 (613) WS34 MD275E88 300 330 1 at +5% 1 at –5% 150 919E 318D 2336 (1061) WS35 MD330E88 400 440 1 at +5% 1 at –5% 150 920E 318D 1 WS35 MD440E88 Catalog Number 2 2 2 2 2 2 2 2 2 2 2 2 230 Delta Volts to 460Y/266 Volts Full Capacity Taps 2 2 hp kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 5 7.5 1 at +5% 1 at –5% 150 912D 347A 158 (72) WS38 MD075E89 7.5 11 1 at +5% 1 at –5% 150 912D 347A 158 (72) WS38 MD11E89 10 14 1 at +5% 1 at –5% 150 912D 347A 158 (72) WS38 MD14E89 15 20 1 at +5% 1 at –5% 150 912D 347A 254 (115) WS38 MD20E89 20 27 1 at +5% 1 at –5% 150 912D 347A 231 (105) WS38 MD27E89 25 34 1 at +5% 1 at –5% 150 912D 347A 310 (141) WS38 MD34E89 30 40 1 at +5% 1 at –5% 150 912D 347A 344 (156) WS38 MD40E89 40 51 1 at +5% 1 at –5% 150 914F 347A 480 (218) WS39 MD51E89 50 63 1 at +5% 1 at –5% 150 914F 347A 457 (207) WS39 MD63E89 60 75 1 at +5% 1 at –5% 150 914F 347A 480 (218) WS39 MD75E89 75 93 1 at +5% 1 at –5% 150 915F 347A 600 (272) WS39 MD93E89 100 118 1 at +5% 1 at –5% 150 916A 347A 941 (427) WS19 MD118E89 125 145 1 at +5% 1 at –5% 150 916A 347A 770 (350) WS19 MD145E89 150 175 1 at +5% 1 at –5% 150 917 321A 1326 (602) WS34 MD175E89 200 220 1 at +5% 1 at –5% 150 918A 321A 1332 (605) WS34 MD220E89 250 275 1 at +5% 1 at –5% 150 918A 321A 1350 (613) WS34 MD275E89 300 330 1 at +5% 1 at –5% 150 919E 321A 2400 (1090) WS35 MD330E89 400 440 1 at +5% 1 at –5% 150 920E 321A 1 WS35 MD440E89 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Contact Eaton. 2 For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-113 2.5 2 Transformers Distribution Transformers Three-Phase Drive Isolation 2 460 Delta Volts to 230Y/133 Volts 2 hp kVA 2 5 7.5 2 2 Full Capacity Taps FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Weight Number Lbs (kg) Weathershield 7.5 1 at +5% 1 at –5% 150 912D 286D 193 (88) WS38 MD075E91 11 1 at +5% 1 at –5% 150 912D 286D 158 (72) WS38 MD11E91 10 14 1 at +5% 1 at –5% 150 912D 286D 158 (72) WS38 MD14E91 15 20 1 at +5% 1 at –5% 150 912D 286D 216 (98) WS38 MD20E91 20 27 1 at +5% 1 at –5% 150 912D 286D 231 (105) WS38 MD27E91 2 25 34 1 at +5% 1 at –5% 150 912D 286D 340 (154) WS38 MD34E91 30 40 1 at +5% 1 at –5% 150 912D 286D 339 (154) WS38 MD40E91 2 40 51 1 at +5% 1 at –5% 150 914 286D 535 (243) WS39 MD51E91 2 50 63 1 at +5% 1 at –5% 150 914F 286D 480 (218) WS39 MD63E91 60 75 1 at +5% 1 at –5% 150 914F 286D 469 (213) WS39 MD75E91 2 75 93 1 at +5% 1 at –5% 150 915F 286D 727 (330) WS39 MD93E91 100 118 1 at +5% 1 at –5% 150 916A 286D 770 (350) WS19 MD118E91 2 125 145 1 at +5% 1 at –5% 150 916A 286D 770 (350) WS19 MD145E91 150 175 1 at +5% 1 at –5% 150 917 286D 1100 (499) WS34 MD175E91 2 200 220 1 at +5% 1 at –5% 150 917 286D 1299 (590) WS34 MD220E91 2 250 275 1 at +5% 1 at –5% 150 918A 286D 1596 (725) WS34 MD275E91 300 330 1 at +5% 1 at –5% 150 919E 318E 2234 (1014) WS35 MD330E91 400 440 1 at +5% 1 at –5% 150 919E 318E 2400 (1090) WS35 MD440E91 2 Catalog Number 2 460 Delta Volts to 400Y/231 Volts 2 hp kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Weight Number Lbs (kg) Weathershield Catalog Number 2 5 7.5 1 at +5% 1 at –5% 150 912D 286D 193 (88) WS38 MD075E75 2 7.5 11 1 at +5% 1 at –5% 150 912D 286D 158 (72) WS38 MD11E75 10 14 1 at +5% 1 at –5% 150 912D 286D 158 (72) WS38 MD14E75 2 15 20 1 at +5% 1 at –5% 150 912D 286D 216 (98) WS38 MD20E75 20 27 1 at +5% 1 at –5% 150 912D 286D 231 (105) WS38 MD27E75 2 25 34 1 at +5% 1 at –5% 150 912D 286D 340 (154) WS38 MD34E75 30 40 1 at +5% 1 at –5% 150 912D 286D 339 (154) WS38 MD40E75 2 40 51 1 at +5% 1 at –5% 150 914F 286D 535 (243) WS39 MD51E75 2 50 63 1 at +5% 1 at –5% 150 914F 286D 480 (218) WS39 MD63E75 60 75 1 at +5% 1 at –5% 150 914F 286D 469 (213) WS39 MD75E75 2 75 93 1 at +5% 1 at –5% 150 915F 286D 727 (330) WS39 MD93E75 100 118 1 at +5% 1 at –5% 150 916A 286D 770 (350) WS19 MD118E75 2 125 145 1 at +5% 1 at –5% 150 916A 286D 770 (350) WS19 MD145E75 150 175 1 at +5% 1 at –5% 150 917 286D 1100 (499) WS34 MD175E75 2 200 220 1 at +5% 1 at –5% 150 917 286D 1299 (590) WS34 MD220E75 2 250 275 1 at +5% 1 at –5% 150 918A 286D 1596 (725) WS34 MD275E75 300 330 1 at +5% 1 at –5% 150 919E 318E 2234 (1014) WS35 MD330E75 400 440 1 at +5% 1 at –5% 150 919E 318E 2400 (1090) WS35 MD440E75 2 2 Full Capacity Taps Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 V2-T2-114 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Three-Phase Drive Isolation 2 2 460 Delta Volts to 460Y/266 Volts Full Capacity Taps FCAN FCBN ºC Temp. Rise 7.5 1 at +5% 1 at –5% 150 912D 286D 164 (74) WS38 MD075E92 11 1 at +5% 1 at –5% 150 912D 286D 161 (73) WS38 MD11E92 10 14 1 at +5% 1 at –5% 150 912D 286D 173 (79) WS38 MD14E92 15 20 1 at +5% 1 at –5% 150 912D 286D 231 (105) WS38 MD20E92 20 27 1 at +5% 1 at –5% 150 912D 286D 250 (114) WS38 MD27E92 25 34 1 at +5% 1 at –5% 150 912D 286D 310 (141) WS38 MD34E92 30 40 1 at +5% 1 at –5% 150 912D 286D 310 (141) WS38 MD40E92 40 51 1 at +5% 1 at –5% 150 914F 286D 503 (228) WS39 MD51E92 50 63 1 at +5% 1 at –5% 150 914F 286D 535 (243) WS39 MD63E92 60 75 1 at +5% 1 at –5% 150 914F 286D 535 (243) WS39 MD75E92 75 93 1 at +5% 1 at –5% 150 916A 286D 710 (322) WS19 MD93E92 100 118 1 at +5% 1 at –5% 150 916A 286D 770 (350) WS19 MD118E92 125 145 1 at +5% 1 at –5% 150 916A 286D 866 (393) WS19 MD145E92 150 175 1 at +5% 1 at –5% 150 917 286D 1100 (499) WS34 MD175E92 200 220 1 at +5% 1 at –5% 150 917 286D 1100 (499) WS34 MD220E92 250 275 1 at +5% 1 at –5% 150 918A 286D 1469 (667) WS34 MD275E92 300 330 1 at +5% 1 at –5% 150 919E 318E 2587 (1174) WS35 MD330E92 400 440 1 at +5% 1 at –5% 150 919E 318E 2500 (1135) WS35 MD440E92 hp kVA 5 7.5 Frame Wiring Diagram Weight Number Lbs (kg) Weathershield Catalog Number 2 2 2 2 2 2 2 2 2 2 2 Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-115 2.5 2 Transformers Distribution Transformers Three-Phase Drive Isolation 2 480 Delta Volts to 240 Delta Volts 2 hp kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Weight Number Lbs (kg) Weathershield 5 7.5 1 at +5% 1 at –5% 150 912D 300A 193 (88) WS38 MD075E77 7.5 11 1 at +5% 1 at –5% 150 912D 300A 158 (72) WS38 MD11E77 2 10 14 1 at +5% 1 at –5% 150 912D 300A 158 (72) WS38 MD14E77 2 15 20 1 at +5% 1 at –5% 150 912D 300A 185 (84) WS38 MD20E77 20 27 1 at +5% 1 at –5% 150 912D 300A 231 (105) WS38 MD27E77 2 25 34 1 at +5% 1 at –5% 150 912D 300A 329 (149) WS38 MD34E77 30 40 1 at +5% 1 at –5% 150 912D 300A 339 (154) WS38 MD40E77 2 40 51 1 at +5% 1 at –5% 150 914F 300A 535 (243) WS39 MD51E77 2 50 63 1 at +5% 1 at –5% 150 914F 300A 480 (218) WS39 MD63E77 60 75 1 at +5% 1 at –5% 150 914F 300A 469 (213) WS39 MD75E77 2 75 93 1 at +5% 1 at –5% 150 915F 300A 727 (330) WS39 MD93E77 100 118 1 at +5% 1 at –5% 150 916A 300A 770 (350) WS19 MD118E77 2 125 145 1 at +5% 1 at –5% 150 916A 300A 770 (350) WS19 MD145E77 150 175 1 at +5% 1 at –5% 150 917 300A 1100 (499) WS34 MD175E77 2 200 220 1 at +5% 1 at –5% 150 917 300A 1299 (590) WS34 MD220E77 2 250 275 1 at +5% 1 at –5% 150 918A 300A 1596 (725) WS34 MD275E77 300 330 1 at +5% 1 at –5% 150 919E 348D 2234 (1014) WS35 MD330E77 400 440 1 at +5% 1 at –5% 150 919E 348D 2400 (1090) WS35 MD440E77 2 2 Full Capacity Taps Catalog Number 2 480 Delta Volts to 480 Delta Volts 2 hp kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Weight Number Lbs (kg) Weathershield Catalog Number 2 5 7.5 1 at +5% 1 at –5% 150 912D 300A 193 (88) WS38 MD075E99 2 7.5 11 1 at +5% 1 at –5% 150 912D 300A 158 (72) WS38 MD11E99 10 14 1 at +5% 1 at –5% 150 912D 300A 158 (72) WS38 MD14E99 2 15 20 1 at +5% 1 at –5% 150 912D 300A 185 (84) WS38 MD20E99 20 27 1 at +5% 1 at –5% 150 912D 300A 231 (105) WS38 MD27E99 2 25 34 1 at +5% 1 at –5% 150 912D 300A 329 (149) WS38 MD34E99 30 40 1 at +5% 1 at –5% 150 912D 300A 339 (154) WS38 MD40E99 2 40 51 1 at +5% 1 at –5% 150 914F 300A 535 (243) WS39 MD51E99 2 50 63 1 at +5% 1 at –5% 150 914F 300A 480 (218) WS39 MD63E99 60 75 1 at +5% 1 at –5% 150 914F 300A 469 (213) WS39 MD75E99 75 93 1 at +5% 1 at –5% 150 915F 300A 727 (330) WS39 MD93E99 100 118 1 at +5% 1 at –5% 150 916A 300A 770 (350) WS19 MD118E99 2 2 Full Capacity Taps 125 145 1 at +5% 1 at –5% 150 916A 300A 770 (350) WS19 MD145E99 150 175 1 at +5% 1 at –5% 150 917 300A 1100 (499) WS34 MD175E99 2 200 220 1 at +5% 1 at –5% 150 917 300A 1299 (590) WS34 MD220E99 2 250 275 1 at +5% 1 at –5% 150 918A 300A 1596 (725) WS34 MD275E99 300 330 1 at +5% 1 at –5% 150 919E 348D 2234 (1014) WS35 MD330E99 400 440 1 at +5% 1 at –5% 150 919E 348D 2400 (1090) WS35 MD440E99 2 2 Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 V2-T2-116 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Three-Phase Drive Isolation 2 2 575 Delta Volts to 460Y/266 Volts Full Capacity Taps hp kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Weight Number Lbs (kg) Weathershield Catalog Number 5 7.5 1 at +5% 1 at –5% 150 912D 286H 158 (72) WS38 MD075E95 7.5 11 1 at +5% 1 at –5% 150 912D 286H 158 (72) WS38 MD11E95 10 14 1 at +5% 1 at –5% 150 912D 286H 158 (72) WS38 MD14E95 15 20 1 at +5% 1 at –5% 150 912D 286H 272 (123) WS38 MD20E95 20 27 1 at +5% 1 at –5% 150 912D 286H 266 (121) WS38 MD27E95 25 34 1 at +5% 1 at –5% 150 912D 286H 360 (163) WS38 MD34E95 30 40 1 at +5% 1 at –5% 150 912D 286H 310 (141) WS38 MD40E95 40 51 1 at +5% 1 at –5% 150 914F 286H 504 (229) WS39 MD51E95 50 63 1 at +5% 1 at –5% 150 914F 286H 506 (230) WS39 MD63E95 60 75 1 at +5% 1 at –5% 150 914F 286H 524 (238) WS39 MD75E95 75 93 1 at +5% 1 at –5% 150 916A 286H 730 (331) WS19 MD93E95 100 118 1 at +5% 1 at –5% 150 916A 286H 770 (350) WS19 MD118E95 125 145 1 at +5% 1 at –5% 150 916A 286H 770 (350) WS19 MD145E95 150 175 1 at +5% 1 at –5% 150 917 286H 1282 (582) WS34 MD175E95 200 220 1 at +5% 1 at –5% 150 917 286H 1201 (545) WS34 MD220E95 250 275 1 at +5% 1 at –5% 150 923 318F 702 (319) WS37 MD275E95 300 330 1 at +5% 1 at –5% 150 919E 318F 2263 (1027) WS35 MD330E95 400 440 1 at +5% 1 at –5% 150 919E 318F 2400 (1090) WS35 MD440E95 2 2 2 2 Weathershield 912D 286H 158 (72) WS38 MD075E96 912D 286H 158 (72) WS38 MD11E96 912D 286H 231 (105) WS38 MD14E96 912D 286H 231 (105) WS38 MD20E96 150 912D 286H 231 (105) WS38 MD27E96 150 912D 286H 261 (118) WS38 MD34E96 1 at –5% 150 912D 286H 310 (141) WS38 MD40E96 1 at +5% 1 at –5% 150 914F 286H 480 (218) WS39 MD51E96 1 at +5% 1 at –5% 150 914F 286H 500 (227) WS39 MD63E96 75 1 at +5% 1 at –5% 150 914F 286H 538 (244) WS39 MD75E96 93 1 at +5% 1 at –5% 150 916A 286H 600 (272) WS19 MD93E96 118 1 at +5% 1 at –5% 150 916A 286H 948 (430) WS19 MD118E96 FCBN 2 2 2 2 2 2 Wiring Diagram Weight Number Lbs (kg) FCAN 2 2 575 Delta Volts to 575Y/332 Volts Full Capacity Taps 2 ºC Temp. Rise hp kVA 5 7.5 1 at +5% 1 at –5% 150 7.5 11 1 at +5% 1 at –5% 150 10 14 1 at +5% 1 at –5% 150 15 20 1 at +5% 1 at –5% 150 20 27 1 at +5% 1 at –5% 25 34 1 at +5% 1 at –5% 30 40 1 at +5% 40 51 50 63 60 75 100 Frame Catalog Number 125 145 1 at +5% 1 at –5% 150 916A 286H 868 (394) WS19 MD145E96 150 175 1 at +5% 1 at –5% 150 917 286H 1320 (599) WS34 MD175E96 200 220 1 at +5% 1 at –5% 150 917 286H 1332 (605) WS34 MD220E96 250 275 1 at +5% 1 at –5% 150 918A 318F 1350 (613) WS34 MD275E96 300 330 1 at +5% 1 at –5% 150 919E 318F 2336 (1061) WS35 MD330E96 400 440 1 at +5% 1 at –5% 150 919E 318F 2500 (1137) WS35 MD440E96 2 2 2 2 2 2 2 2 2 2 2 Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-117 2.5 2 Accessories 2 ● 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 ● ● ● ● ● Transformers Distribution Transformers Copper windings Non-standard voltages 50/60 Hz designs Delta-delta configuration 80°C or 115°C rise designs Encapsulated designs (up to 34 kVA). Thermoguards are not available on encapsulated designs ● ● Totally enclosed non-ventilated Electrostatic shields Please refer to Section 2.7 Page V2-T2-191. Technical Data and Specifications Frequency Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 40°C 80°C 30°C 150°C 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C 40°C 150°C 30°C 220°C The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. Enclosures Eaton ventilated transformers, Type MD, use a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Sound Levels All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Ventilated transformers have leads brought out to aluminum pads that are predrilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. Eaton recommends that external cables be rated 75°C for ventilated designs. For additional information, please refer to Section 2.7 Page V2-T2-195. Average Sound Levels NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 Encapsulated (up to 1.2 kV) 3.00 and below 40 40 45 2 3.01 to 9.00 40 40 45 2 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 2 30.01 to 50.00 45 48 50 50.01 to 75.00 50 53 55 2 75.01 to 112.50 50 53 55 2 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 2 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 2 500.01 to 700.00 62 65 61 700.01 to 1000.00 64 67 63 2 Greater than 1000 Consult factory Consult factory Consult factory 2 Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. 2 V2-T2-118 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Contents Description Page Motor Drive Isolation Transformers . . . . . . . . . . . . Mini–Power Centers Standards and Certifications. . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers. . . . Class I, Division 2, Hazardous Location Transformers Open-Type Core and Coil Assembly Transformers Marine Duty Transformers. . . . . . . . . . . . . . . . . . . Buck-Boost and Low Voltage Lighting Transformers Medium Voltage Distribution Transformers . . . . . . V2-T2-111 V2-T2-120 V2-T2-121 V2-T2-121 V2-T2-123 V2-T2-123 V2-T2-124 V2-T2-127 V2-T2-130 V2-T2-133 V2-T2-144 V2-T2-173 2 2 2 2 2 2 2 2 2 2 2 Mini–Power Centers Product Description Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. ● ● ● ● Encapsulated design Suitable for indoor or outdoor applications 180°C insulation system 115°C rise standard; 80°C rise optional Application Description Features, Benefits and Functions A mini–power center combines three individual components into one NEMA Type 3R enclosure: a main breaker, an encapsulated single-phase (Type EP) or three-phase (EPT) dry-type transformer, and a secondary distribution loadcenter with main breaker. Interconnecting wiring is completed at the factory. Mini–power centers are used wherever there is a 480 volt or 600 volt distribution system and loads requiring 208Y/120 volt, three-phase or 120/240 volt single-phase. Typical installations include: ● Industrial plant assembly lines Plant expansions Test equipment Temporary construction site power Sewage disposal plants Warehouses Car washes Parking lots Commercial buildings ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 60 Hz operation Indoor/outdoor, NEMA 3R Primary main breaker Secondary main breaker (Type BR plug-in and Type BAB bolt-on feeder breakers not included) All live parts enclosed for personnel safety Cover is hinged to prevent removal and can be padlocked Cores are grounded with a copper lead Ground bar is supplied to permit grounding of individual secondary circuits Neutral bar is grounded to case Feeder circuits can be easily added or changed using Type BR plug-in breakers and Type BR plugin and Type BAB bolt-on ● ● ● ● Suitable for service entrance Wide range of configurations available: ● Aluminum windings and plug-in loadcenter chassis standard ● Copper windings and plug-in loadcenter chassis also available ● Copper windings and bolt-on loadcenter chassis available Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-119 2.5 Transformers Distribution Transformers 2 Standards and Certifications 2 ● ● UL listed CSA® certified 2 2 2 2 2 2 2 2 2 2 Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the International Building Code (IBC) and California Code Title 24. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-120 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.5 Transformers Distribution Transformers Catalog Number Selection Please refer to Section 2.7 Page V2-T2-187. 2 Product Selection 2 Additional Product Selection information begins on Page V2-T2-189. 2 Single-Phase 2 2 480 Volts to 120/240 Volts Main Circuit Breaker Feeder Breakers Max. Number 23 Primary 1 Single-Pole kVA Full Capacity Taps FCBN Frame Wiring Diagram Number 3 2 at –5% FR283 97A3K 105 (47) EHD2015 BR215 8 5 2 at –5% FR284 110A5K 110 (50) EHD2020 BR225 12 7.5 2 at –5% FR284 109A7K 125 (56) EHD2030 BR230 12 10 2 at –5% FR285 108A10K 180 (82) EHD2040 BR250 15 2 at –5% FR286 107A15K 215 (98) EHD2060 BR270 25 2 at –5% FR287 106A25K 373 (169) EHD2100 BR2125 Weight Lbs (kg) Secondary 2 Max. Amp Catalog Number 4 12 P48G11S03P 6 20 P48G11S05P 6 30 P48G11S07P 12 6 40 P48G11S10P 20 10 60 P48G11S15P 26 13 100 P48G11S25P Two-Pole kVA 5 2 at –5% Feeder Breakers Max. Number 23 Frame Wiring Diagram Number Weight Lbs (kg) Primary 1 Secondary Single-Pole FR284 110B5K 110 (50) FDB2015 BR225 12 Main Circuit Breaker Two-Pole Max. Amp Catalog Number 6 20 P60G11S05P 7.5 2 at –5% FR284 109B7K 125 (56) FDB2030 BR230 12 6 30 P60G11S07P 10 2 at –5% FR285 108B10K 180 (82) FDB2040 BR250 12 6 40 P60G11S10P 15 2 at –5% FR286 107B15K 215 (98) FDB2060 BR270 20 10 60 P60G11S15P 25 2 at –5% FR287 106B25K 373 (169) FDB2100 BR2125 26 13 100 P60G11S25P kVA 2 at –5% Feeder Breakers Max. Number 23 Frame Wiring Diagram Number Weight Lbs (kg) Primary Secondary Single-Pole Two-Pole FR289A 105A15K 320 (145) EHD3040 BR350 18 9 Main Circuit Breaker Three-Pole Max. Amp Catalog Number 6 40 P48G28T15P 22.5 2 at –5% FR290A 103A21K 565 (256) EHD3070 BR370 18 9 6 60 P48G28T21P 30 2 at –5% FR291A 104A30K 635 (288) EHD3090 BR3100 24 12 8 80 P48G28T30P Full Capacity Taps FCBN 2 2 2 2 2 Frame 2 2 2 2 2 600 Delta Volts to 208Y/120 Volts kVA 2 2 480 Delta Volts to 208Y/120 Volts 15 2 2 Three-Phase Full Capacity Taps FCBN 2 2 600 Volts to 120/240 Volts Full Capacity Taps FCBN 2 Wiring Diagram Number Weight Lbs (kg) Main Circuit Breaker Feeder Breakers Max. Number 23 Primary Single-Pole Secondary Two-Pole Three-Pole Max. Amp Catalog Number 15 2 at –5% FR289A 105D15K 320 (145) FDB3030 BR350 18 9 6 40 P60G28T15P 22.5 2 at –5% FR290A 103B21K 565 (256) FDB3050 BR370 18 9 6 60 P60G28T21P 30 2 at –5% FR291A 104B30K 635 (288) FDB3070 BR3100 24 12 8 80 P60G28T30P 2 2 2 Notes 1 Primary breakers with higher interrupting capacity available. For HFD breaker, add suffix “H.” For FD breaker, add suffix “F.” For FDC breaker, add suffix “C.” Main breakers are fixed only. 2 Combinations can be selected. 3 Feeder breakers not included. Use Eaton’s Type BR. 2 For 304 grade stainless steel enclosure, replace 10th character of catalog number with an “SS” suffix, e.g., P48G11S03SS, or add “SS” suffix before the addition of “CUB.” For 316 grade stainless steel enclosure, replace 10th character of catalog number with an “S6” suffix, e.g., P48G11S03S6, or add “S6” suffix before the addition of “CUB.” For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2 V2-T2-121 2 2 2.5 2 2 2 480 Volts to 120/240 Volts Main Circuit Breaker Feeder Breakers Max. Number 23 Frame Wiring Diagram Number Weight Lbs (kg) Primary 1 Secondary Single-Pole Two-Pole Max. Amp Catalog Number 2 at –5% FR306 97A3K 105 (47) EHD2015L BAB2015 8 4 12 P48G11S03CUB 2 at –5% FR307 110A5K 110 (50) EHD2020L BAB2025 12 6 20 P48G11S05CUB 7.5 2 at –5% FR307 109A7K 110 (50) EHD2030L BAB2030 12 6 30 P48G11S07CUB 10 2 at –5% FR308 108A10K 180 (82) EHD2040L BAB2050 12 6 40 P48G11S10CUB 15 2 at –5% FR309 108A15K 215 (98) EHD2060L BAB2070 24 12 60 P48G11S15CUB 25 2 at –5% FR310 106A25K 385 (175) EHD2100L BAB2125 26 13 100 P48G11S25CUB Main Circuit Breaker Feeder Breakers Max. Number 23 Weight Lbs (kg) Primary 1 Secondary Single-Pole Two-Pole Max. Amp Catalog Number kVA 3 2 5 2 2 2 2 Distribution Transformers All Copper, Bolt-On Breaker Designs—Single-Phase Full Capacity Taps FCBN 2 Transformers 600 Volts to 120/240 Volts kVA Full Capacity Taps FCBN Frame Wiring Diagram Number 3 2 at –5% FR306 97B3K 105 (47) FDB2015L BAB2015 8 4 12 P60G11S03CUB 5 2 at –5% FR307 110B5K 110 (50) FDB2020L BAB2025 12 6 20 P60G11S05CUB 2 7.5 2 at –5% FR307 109B7K 110 (50) FDB2030L BAB2030 12 6 30 P60G11S07CUB 10 2 at –5% FR308 108B10K 180 (82) FDB2040L BAB2050 12 6 40 P60G11S10CUB 2 15 2 at –5% FR309 108B15K 215 (98) FDB2060L BAB2070 24 12 60 P60G11S15CUB 25 2 at –5% FR310 106B25K 385 (175) FDB2100L BAB2125 26 13 100 P60G11S25CUB Main Circuit Breaker Feeder Breakers Max. Number 23 Weight Lbs (kg) Primary Secondary Single-Pole Two-Pole Three-Pole Max. Amp 2 2 2 2 2 2 2 2 Three-Phase 480 Volts to 208Y/120 Volts kVA Full Capacity Taps FCBN Frame Wiring Diagram Number Catalog Number 15 2 at –5% FR289A 105A15K 320 (145) EHD3040L BAB3050H 18 9 6 40 P48G28T15CUB 22.5 2 at –5% FR290A 103A21K 565 (257) EHD3070L BAB3070H 18 9 6 60 P48G28T21CUB 30 2 at –5% FR291A 104A30K 635 (288) EHD3090L BAB3100H 24 12 8 80 P48G28T30CUB Main Circuit Breaker Feeder Breakers Max. Number 23 Weight Lbs (kg) Primary Secondary Single-Pole Two-Pole Three-Pole Max. Amp Catalog Number 2 2 600 Volts to 208Y/120 Volts kVA Full Capacity Taps FCBN Frame Wiring Diagram Number 2 15 2 at –5% FR289A 105D15K 320 (145) FDB3030L BAB3050H 18 9 6 40 P60G28T15CUB 22.5 2 at –5% FR290A 103B21K 565 (257) FDB3050L BAB3070H 18 9 6 60 P60G28T21CUB 2 30 2 at –5% FR291A 104B30K 635 (288) FDB3070L BAB3100H 24 12 8 80 P60G28T30CUB 2 2 Notes 1 Primary breakers with higher interrupting capacity available. For HFD breaker, add suffix “H.” For FD breaker, add suffix “F.” For FDC breaker, add suffix “C.” Main breakers are fixed only. UL Listed only, not CSA. 2 Combinations can be selected. 3 Feeder breakers not included. Use Eaton’s Type BAB. 2 For 304 grade stainless steel enclosure, replace 10th character of catalog number with an “SS” suffix, e.g., P48G11S03SS, or add “SS” suffix before the addition of “CUB.” For 316 grade stainless steel enclosure, replace 10th character of catalog number with an “S6” suffix, e.g., P48G11S03S6, or add “S6” suffix before the addition of “CUB.” For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 V2-T2-122 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.5 Transformers Distribution Transformers Accessories 2 Please refer to Section 2.7 Page V2-T2-191. 2 Technical Data and Specifications Frequency Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. 2 Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 40°C 80°C 30°C 150°C 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C 40°C 150°C 30°C 220°C The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. Winding Terminations Eaton recommends that external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Sound Levels All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. 2 2 2 2 2 2 Average Sound Levels 2 NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 Encapsulated (up to 1.2 kV) 2 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 2 2 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 50.01 to 75.00 50 53 55 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 500.01 to 700.00 62 65 61 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory 2 2 2 2 2 Note For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. The following pages provide listings for most standard transformer ratings and styles. For all-copper and bolt-on-breaker designs, contact Eaton. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-123 2.5 2 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Contents Description 2 Page Motor Drive Isolation Transformers. . . . . . . . . . . . Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Class I, Division 2, Hazardous Location Transformers Open-Type Core and Coil Assembly Transformers Marine Duty Transformers . . . . . . . . . . . . . . . . . . Buck-Boost and Low Voltage Lighting Transformers Medium Voltage Distribution Transformers. . . . . . 2 2 2 2 2 2 V2-T2-111 V2-T2-119 V2-T2-125 V2-T2-125 V2-T2-126 V2-T2-126 V2-T2-127 V2-T2-130 V2-T2-133 V2-T2-144 V2-T2-173 2 2 2 Totally Enclosed Non-Ventilated Transformers 2 Product Description 2 2 2 2 2 Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. ● ● 2 2 2 ● ● Suitable for indoor or outdoor applications Totally enclosed, nonventilated enclosures rated NEMA 3R 220°C insulation system 150°C rise standard; 115°C or 80°C rise optional 2 2 2 2 2 2 2 Application Description Totally enclosed nonventilated dry-type transformers are for special applications, where because of adverse atmospheric conditions it is desirable to use a dry-type non-ventilated transformer vs. the ventilated standard unit, which has openings in its enclosure to allow air to flow directly over the core and coil. Features, Benefits and Functions ● ● ● 60 Hz operation (50/60 Hz operation available) Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels In applications where the atmosphere contains conductive, corrosive, or combustible materials, which might damage a transformer, or lint and dust flyings that might block the ventilation passages, the non-ventilated transformer is highly suited. It has no openings in the enclosure. Heat is dissipated by radiating from the surface area of the enclosure. Consequently, the enclosures are larger than those of the standard ventilated type. Non-ventilated transformers are suited for application in the textile, chemical, automotive, petrochemical, foundry, cement, food, paper and other industries. 2 2 2 V2-T2-124 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Standards and Certifications ● UL listed Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the International Building Code (IBC) and California Code Title 24. Transformers Distribution Transformers 2.5 Catalog Number Selection Please refer to Section 2.7 Page V2-T2-187. 2 Product Selection 2 Additional Product Selection information begins on Page V2-T2-189. 2 Single-Phase—Type DS-3E, 60 Hz 1 2 2 240 x 480 Volts to 120/240 Volts +1–5%, –2–5% at 240 Volts Primary; +2–2.5%, –4–2.5% at 480 Volts Primary kVA Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Catalog Number 2 15 DS-3E 150 FR817N 3XA 350 (159) T20P11S15NV 25 DS-3E 150 FR818N 3XA 350 (159) T20P11S25NV 2 37.5 DS-3E 150 FR820N 3XA 600 (274) T20P11S37NV 50 DS-3E 150 FR820N 3XA 720 (329) T20P11S50NV Three-Phase—Type DT-3E, 60 Hz 2 2 2 1 2 480 Delta Volts to 208Y/120 Volts +2–2.5% FCAN, 4–2.5% FCBN Taps Frame Wiring Diagram Number Weight Lbs (kg) Catalog Number 2 2 kVA Type °C Temp. Rise 15 DT-3E 150 FR914FN 280B 480 (217) V48M28T15NV 30 DT-3E 150 FR914FN 280B 480 (217) V48M28T30NV 45 DT-3E 150 FR915FN 280B 600 (272) V48M28T45NV 75 DT-3E 150 FR916AN 280B 760 (344) V48M28T75NV 112.5 DT-3E 150 FR917N 280B 1100 (499) V48M28T12NV 150 DT-3E 150 FR918AN 280B 1300 (589) V48M28T49NV 225 DT-3E 150 FR919EN 275A 2400 (1088) V48M28T22NV 300 DT-3E 150 FR920EN 275A 2900 (1315) V48M28T33NV 2 2 2 Notes 1 Transformers Type EPT 75 kVA and smaller three-phase, and Type EP 37.5 kVA and smaller single-phase, are furnished non-ventilated normally, as standard. See general-purpose transformers. Contact your local Eaton sales office for availability of additional totally enclosed non-ventilated transformers. Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-125 2.5 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Transformers Distribution Transformers Accessories Please refer to Section 2.7 Page V2-T2-191. Technical Data and Specifications Frequency Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 40°C 80°C 30°C 150°C 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C 40°C 150°C 30°C 220°C The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. Enclosures Eaton totally enclosed, non-ventilated transformers, Types DS-3E and DT-3E, use a NEMA 3R rated enclosure as standard. Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Totally enclosed nonventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. Eaton recommends external cables be rated 75°C for ventilated designs. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-126 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Series-Multiple Windings Series-multiple windings consist of two similar coils in each winding that can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with an “x” or “/” between the voltage ratings, such as voltages of “120/240” or “240 x 480.” If the series-multiple winding is designated by an “x,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 x 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Note: The preceding pages provide listings for most standard transformer ratings and catalog numbers. For all-copper and bolt-on-breaker designs, contact Eaton. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Transformers Distribution Transformers 2.5 Contents Single-Phase Type EPZ Encapsulated Description Motor Drive Isolation Transformers . . . . . . . . . . . . Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers. . . . Class I, Division 2, Hazardous Location Transformers Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . Open-Type Core and Coil Assembly Transformers Marine Duty Transformers. . . . . . . . . . . . . . . . . . . Buck-Boost and Low Voltage Lighting Transformers Medium Voltage Distribution Transformers . . . . . . Page 2 V2-T2-111 V2-T2-119 V2-T2-124 2 V2-T2-128 V2-T2-128 V2-T2-129 V2-T2-129 V2-T2-130 V2-T2-133 V2-T2-144 V2-T2-173 2 2 2 2 2 2 2 2 2 Class I, Division 2, Hazardous Location Transformers Product Description Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. ● ● ● ● ● ● ● ● Encapsulated design Suitable for indoor or outdoor applications Totally enclosed, nonventilated enclosures 180°C insulation system 115°C rise standard; 80°C rise optional Mountable in any position indoors. Upright only outdoors Available in ratings up to 600 volts primary, 25 kVA single-phase, 75 kVA three-phase Available in NEMA Type 4X enclosure Application Description Type EPZ and EPTZ transformers are labeled as “Suitable for use in Class I, Division 2, Groups A, B, C and D locations, as defined by NEC Article 501, with NECrecommended installation procedures for dry-type transformers rated under 600 volts nominal operation.” A Class I, Division 2 location per Section 500 of the NEC is defined as: 6. A location in which volatile flammable liquids or gases are handled, processed or used, but that normally will be confined within closed containers or systems from which they can escape only in case of accidental rupture or breakdown of the container or system. 7. Or, a location where ignitable concentrations of gases or vapors are normally prevented by positive mechanical ventilation and that might become hazardous through failure of the ventilation equipment. Standards and Certifications 8. Or, a location that is adjacent to a Class I, Division 1 location and ignitable concentrations of gases or vapors might occasionally enter. Atmospheres classified by NEC Section 500 as Group A includes acetylene. Group B includes gases such as hydrogen and formaldehyde. Group C may contain gases or vapors such as ethyl ether, ethylene, or the equivalent. Atmospheres classified as Group D may contain gases or vapors such as acetone, ammonia, benzene, butane, cyclopropane, ethanol, gasoline, hexane, methanol, methane, natural gas, naphtha, propane or the equivalent. ● UL listed 2 2 Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the International Building Code (IBC) and California Code Title 24. ● ● ● ● 2 2 2 2 2 2 2 2 2 Features, Benefits and Functions ● 2 2 NEMA 3R enclosure 60 Hz operation Aluminum windings (copper optional) Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-127 2.5 2 2 Transformers Distribution Transformers Catalog Number Selection Please refer to Section 2.7 Page V2-T2-187. Product Selection 2 Additional Product Selection information begins on Page V2-T2-189. 2 Single-Phase—Type EPZ, 60 Hz 2 480 Volts to 120/240 Volts 2 kVA FCAN FCBN Type 2 0.05 — — EPZ 115 FR57H 2 0.75 — — EPZ 115 FR58H 1 — — EPZ 115 FR59H 2 1.5 — — EPZ 115 2 — — EPZ 2 3 — — 2 5 — 7.5 — 2 10 2 2 2 2 Full Capacity Taps °C Temp. Rise Weight Lbs (kg) Catalog Number 524H 13 (6) Z48N11S51A 524H 21 (10) Z48N11S76A 524H 31 (14) Z48N11S01A FR67H 524H 40 (18) Z48N11S16A 115 FR68H 524H 40 (18) Z48N11S02A EPZ 115 FR176H 524H 65 (30) Z48N11S03A — EPZ 115 FR177H 524H 113 (51) Z48N11S05A — EPZ 115 FR178H 524H 123 (56) Z48N11S07A — — EPZ 115 FR179H 524H 193 (88) Z48N11S10A 15 — — EPZ 115 FR180H 524H 216 (98) Z48N11S15A 25 — — EPZ 115 FR182H 524H 375 (170) Z48N11S25A Catalog Number Frame Wiring Diagram Number Three-Phase—Type EPTZ, 60 Hz 480 Delta Volts to 208Y/120 Volts Three-Phase Full Capacity Taps kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) 3 — 2 at –5% EPTZ 115 FR201H 70A 116 (53) Z48G28T03A 2 6 — 2 at –5% EPTZ 115 FR200H 70A 143 (65) Z48G28T06A 2 9 — 2 at –5% EPTZ 115 FR103H 70A 166 (75) Z48G28T09A 15 — 2 at –5% EPTZ 115 FR95H 70A 275 (125) Z48G28T15A 2 30 — 2 at –5% EPTZ 115 FR243H 66A 422 (191) Z48G28T30A 45 — 2 at –5% EPTZ 115 FR244H 66A 660 (299) Z48G28T45A 2 75 — 2 at –5% EPTZ 115 FR245H 66A 1275 (580) Z48G28T75A 1 2 2 2 480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on B Phase 2 Full Capacity Taps kVA FCAN FCBN Type °C Temp. Rise Frame 6 — 2 at –5% EPTZ 115 FR102H 95A 115 (52) Z48G22T06A 2 9 — 2 at –5% EPTZ 115 FR97H 95A 160 (73) Z48G22T09A 15 — 2 at –5% EPTZ 115 FR195H 95A 340 (155) Z48G22T15A 2 30 — 2 at –5% EPTZ 115 FR243H 62A 422 (191) Z48G22T30A 45 — 2 at –5% EPTZ 115 FR244H 62A 660 (299) Z48G22T45A 2 2 2 2 Wiring Diagram Number Weight Lbs (kg) Catalog Number Notes 1 Floor-mount only. 2 Center Tap capacity limited to 5% of rated kVA. For 316 grade stainless steel enclosure, replace 10th character of catalog number with an “SS” suffix. Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 V2-T2-128 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Accessories Please refer to Section 2.7 Page V2-T2-191. 2 Technical Data and Specifications 2 Frequency Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour, and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 40°C 80°C 30°C 150°C 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C 40°C 150°C 30°C 220°C The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. Enclosures Eaton encapsulated transformers, Types EPZ and EPTZ, use a NEMA 3R rated enclosure. Sound Levels All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Winding Terminations Lugs are not supplied with these transformers. Eaton recommends that external cables be rated 90°C sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Series-Multiple Windings Series-multiple windings consist of two similar coils in each winding that can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with an “x” or “/” between the voltage ratings, such as voltages of “120/240” or “240 x 480.” If the series-multiple winding is designated by an “x,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 x 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), 240 (series) or 240 with a 120 mid-point. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Nominal and tap leads come out of the transformer through pipe elbows. Connections should be made to an adjacent explosion-proof junction box. Unused tap leads must be properly insulated prior to energization. EPZ and EPTZ transformers are UL and cUL listed. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-129 2.5 Transformers Distribution Transformers Contents 2 Description 2 Page Motor Drive Isolation Transformers. . . . . . . . . . . . Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers . . . Class I, Division 2, Hazardous Location Transformers Open-Type Core and Coil Assembly Transformers Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Marine Duty Transformers . . . . . . . . . . . . . . . . . . Buck-Boost and Low Voltage Lighting Transformers Medium Voltage Distribution Transformers. . . . . . 2 2 2 2 2 2 V2-T2-111 V2-T2-119 V2-T2-124 V2-T2-127 V2-T2-131 V2-T2-131 V2-T2-132 V2-T2-132 V2-T2-133 V2-T2-144 V2-T2-173 2 2 2 Open-Type Core and Coil Assembly Transformers 2 Product Description 2 2 2 2 Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. ● 2 2 ● 220°C insulation system; 150°C rise standard; 115°C or 80°C optional Aluminum windings (copper optional) 2 Application Description The basic purpose of a transformer is voltage transformation as near as practically possible to the load for economy and distribution of power. Typical loads for dry-type distribution transformers include lighting, heating, air conditioners, fans and machine tools. Such loads are found in commercial, institutional, industrial and residential structures. Features, Benefits and Functions ● ● ● 60 Hz operation standard, 50/60 Hz operation available Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels Open core and coil assemblies are typically used by panel builders and equipment OEM customers who incorporate the entire transformer into their structures, making these assemblies a versatile option to purchasing a standard, enclosed transformer and discarding the unneeded enclosure parts. 2 2 2 2 2 2 2 2 2 2 2 V2-T2-130 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Standards and Certifications ● UL recognized Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. Seismically Qualified All Eaton manufactured drytype distribution transformers are seismically qualified and exceed requirements of the International Building Code and California Code Title 24. 2.5 Transformers Distribution Transformers Catalog Number Selection Please refer to Section 2.7 Page V2-T2-187. 2 Product Selection 2 Additional Product Selection information begins on Page V2-T2-189. 2 Single-Phase—Type DS-3C, 60 Hz 2 2 240 x 480 Volts to 120/240 Volts Full Capacity Taps kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Catalog Number 15 1 1 DS-3C 150 CS15G103 3XA 246 (112) T20P11S15EEZZ 25 1 1 DS-3C 150 CS25E103 3XA 359 (163) T20P11S25EEZZ 37.5 1 1 DS-3C 150 CS37C103 3XA 374 (170) T20P11S37EEZZ 50 1 1 DS-3C 150 CS50G103 3XA 555 (252) T20P11S50EEZZ 2 2 2 2 2 Three-Phase—Type DT-3C, 60 Hz 2 480 Delta Volts to 208Y/120 Volts Full Capacity Taps 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3C 150 CT15H103 280B 191 (87) V48M28T15EEZZ 30 2 at +2.5% 4 at –2.5% DT-3C 150 CT30E103 280B 251 (114) V48M28T30EEZZ 45 2 at +2.5% 4 at –2.5% DT-3C 150 CT45E103 280B 367 (167) V48M28T45EEZZ 75 2 at +2.5% 4 at –2.5% DT-3C 150 CT75E103 280B 491 (223) V48M28T75EEZZ 112.5 2 at +2.5% 4 at –2.5% DT-3C 150 — 280B 676 (307) V48M28T12EEZZ 150 2 at +2.5% 4 at –2.5% DT-3C 150 — 280B 796 (362) V48M28T49EEZZ 2 2 2 2 Notes 1 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary. 2 Contact your local Eaton sales office for availability of additional open-type core and coil assemblies. Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-131 2.5 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Transformers Distribution Transformers Accessories Please refer to Section 2.7 Page V2-T2-191. Technical Data and Specifications Frequency Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour, and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. 2 2 2 Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 40°C 80°C 30°C 150°C 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C 40°C 150°C 30°C 220°C The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. Winding Terminations Lugs are not supplied with these transformers. Eaton recommends that external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Series-Multiple Windings Series-multiple windings consist of two similar coils in each winding that can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with an “x” or “/” between the voltage ratings, such as voltages of “120/240” or “240 x 480.” If the seriesmultiple winding is designated by an “x,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 x 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), 240 (series) or 240 with a 120 mid-point. Sound Levels All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. For additional information, please refer to Section 2.7 Page V2-T2-195. Average Sound Levels NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 Encapsulated (up to 1.2 kV) 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 9.01 to 15.00 45 45 50 2 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 2 50.01 to 75.00 50 53 55 75.01 to 112.50 50 53 55 2 112.51 to 150.00 50 53 55 2 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 2 300.01 to 500.00 60 63 59 500.01 to 700.00 62 65 61 2 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory 2 2 2 2 2 V2-T2-132 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Contents Description Page Motor Drive Isolation Transformers . . . . . . . . . . . . Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers. . . . Class I, Division 2, Hazardous Location Transformers Open-Type Core and Coil Assembly Transformers Marine Duty Transformers Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . Buck-Boost and Low Voltage Lighting Transformers Medium Voltage Distribution Transformers . . . . . . V2-T2-111 V2-T2-119 V2-T2-124 V2-T2-127 V2-T2-130 V2-T2-134 V2-T2-134 V2-T2-143 V2-T2-143 V2-T2-144 V2-T2-173 2 2 2 2 2 2 2 2 2 2 2 Marine Duty Transformers Product Description Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Types EP, EPT ● Encapsulated design ● Suitable for indoor or outdoor applications ● Totally enclosed, nonventilated enclosures ● Enclosures are NEMA 3R rated ● Mountable in any position indoors and upright-only outdoors ● 180ºC insulation system ● 115ºC rise standard; 80°C rise optional ● Copper windings standard ● Available in singlephase ratings through 37.5 kVA (EP) ● Available in threephase ratings through 75 kVA (EPT) Types DS-3, DT-3 Ventilated, NEMA 2 enclosure standard ● Suitable for indoor applications; outdoors when weathershields are also installed ● Upright mounting only ● 220ºC insulation system ● 115ºC rise standard; 150°C or 80°C rise optional ● Copper windings standard ● Available in single-phase ratings 15–167 kVA and up to 4160 volts primary (DS-3) ● Available in three-phase ratings 15–1500 kVA and up to 4160 volts primary (DT-3) ● Application Description Standards and Certifications The basic purpose of a transformer is voltage transformation as near as practically possible to the load for economy and distribution of power. Typical loads for dry-type distribution transformers include lighting, heating, air conditioners, fans and machine tools. Such loads are found in commercial, institutional, industrial and residential structures. ● UL listed 2 2 Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Features, Benefits and Functions ● ● ● ● ● ● ● 2 2 2 2 2 2 2 Meets ABS (American Bureau of Shipping) specification ABS Type Approval Certificate Number 04-TP517621-X 60 Hz operation 115°C temperature rise standard Copper windings standard Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-133 2.5 2 2 Transformers Distribution Transformers Catalog Number Selection Please refer to Section 2.7 Page V2-T2-187. Product Selection 2 Additional Product Selection information begins on Page V2-T2-189. 2 Single-Phase—Type EPM Marine Duty Encapsulated NEMA 3R, 60 Hz 2 240 x 480 Volts to 120/240 Volts—Copper Windings 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 0.05 None None EPM 115 FR52 3A050Q 7 (3) — QS20N11S81CU 0.075 None None EPM 115 FR54 3A075Q 7 (3) — QS20N11S85CU 2 0.1 None None EPM 115 FR54 3A100Q 7 (3) — QS20N11S82CU 2 0.15 None None EPM 115 FR55 3A150Q 8 (4) — QS20N11S83CU 0.25 None None EPM 115 FR56 3A250Q 12 (5) — QS20N11S26CU 2 0.5 None None EPM 115 FR57 3A500Q 13 (6) — QS20N11S51CU 0.75 None None EPM 115 FR58A 3A750Q 21 (10) — QS20N11S76CU 2 1 None None EPM 115 FR59A 3A1Q 31 (14) — QS20N11S01CU 2 1.5 None None EPM 115 FR67 3A16Q 40 (18) — QS20N11S16CU 2 None None EPM 115 FR68 3A2Q 40 (18) — QS20N11S02CU 2 3 None None EPM 115 FR176 3A3Q 72 (33) — QS20N11S03CU 5 None None EPM 115 FR177 3A5Q 125 (57) — QS20N11S05CU 2 7.5 None None EPM 115 FR178 3A7Q 135 (61) — QS20N11S07CU 10 None None EPM 115 FR179 3A10Q 203 (92) — QS20N11S10CU 2 15 None None EPM 115 FR182 3A15Q 231 (105) — QS20N11S15CU 2 25 None None EPM 115 FR300A 128A25Q 380 (173) — QS20N11S25CU 37.5 None None EPM 115 FR300A 248A37Q 856 (389) — QS20L11S37CU 2 2 Full Capacity Taps Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-134 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.5 Transformers Distribution Transformers Single-Phase—Type DS-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1 2 2 120 Volts to 120 Volts—Copper Windings Full Capacity Taps kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DS-3M 115 816 56D15R 275 (125) WS11 RT12M12F15CUEE 25 2 at +2.5% 4 at –2.5% DS-3M 115 818 56D25R 440 (200) WS11 RT12M12F25CUEE 37.5 2 at +2.5% 4 at –2.5% DS-3M 115 818 56D37R 480 (218) WS11 RT12M12F37CUEE 50 2 at +2.5% 4 at –2.5% DS-3M 115 819 56D50R 725 (329) WS16 RT12M12F50CUEE 75 2 at +2.5% 4 at –2.5% DS-3M 115 820 56D75R 820 (372) WS16 RT12M11F75CUEE 100 2 at +2.5% 4 at –2.5% DS-3M 115 821 56D100R 1150 (522) WS13 RT12M11F99CUEE Full Capacity Taps FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DS-3M 115 816 260A15R 275 (125) WS11 RT29M11F15CUEE 25 2 at +2.5% 4 at –2.5% DS-3M 115 818 260A25R 440 (200) WS11 RT29M11F25CUEE 37.5 2 at +2.5% 4 at –2.5% DS-3M 115 818 260A37R 480 (218) WS11 RT29M11F37CUEE 50 2 at +2.5% 4 at –2.5% DS-3M 115 819 260A50R 725 (329) WS16 RT29M11F50CUEE 75 1 at +5% 2 at –5% DS-3M 115 820 260A75R 820 (372) WS16 RT29R11F75CUEE 100 1 at +5% 2 at –5% DS-3M 115 821 260A100R 1150 (522) WS13 RT29R11F99CUEE kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 2 DS-3M 115 816 3XA15R 264 (120) WS11 RT20P11F15CUEE 25 2 2 DS-3M 115 818 3XA25R 420 (191) WS11 RT20P11F25CUEE 37.5 2 2 DS-3M 115 818 3XA37R 450 (204) WS11 RT20P11F37CUEE 50 2 2 DS-3M 115 819 3XA50R 703 (319) WS16 RT20P11F50CUEE 75 2 2 DS-3M 115 820 3XA75R 793 (360) WS16 RT20P11F75CUEE 100 2 2 DS-3M 115 821 3XA100R 1085 (493) WS13 RT20P11F99CUEE 2 2 2 2 2 2 2 2 2 2 2 2 2 277 Volts to 120/240 Volts—Copper Windings Full Capacity Taps 2 2 240 x 480 Volts to 120/240 Volts—Copper Windings Full Capacity Taps 2 2 208 Volts to 120/240 Volts—Copper Windings kVA 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DS-3M 115 816 262C15R 275 (125) WS11 RT27M11F15CUEE 25 2 at +2.5% 4 at –2.5% DS-3M 115 818 262C25R 440 (200) WS11 RT27M11F25CUEE 37.5 2 at +2.5% 4 at –2.5% DS-3M 115 818 262C37R 480 (218) WS11 RT27M11F37CUEE 50 2 at +2.5% 4 at –2.5% DS-3M 115 819 262C50R 725 (329) WS16 RT27M11F50CUEE 75 1 at +5% 2 at –5% DS-3M 115 820 262C75R 820 (372) WS16 RT27M11F75CUEE 100 1 at +5% 2 at –5% DS-3M 115 821 262C100R 1150 (522) WS13 RT27M11F99CUEE Notes 1 Suitable for installation in onshore, onboard or offshore applications. 2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary. 2 2 2 2 2 2 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-135 2.5 2 Transformers Distribution Transformers Single-Phase—Type DS-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1 2 208 x 416 Volts to 120/240 Volts—Copper Windings 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 2 DS-3M 115 816 3XF15R 264 (120) WS11 RT18P11F15CUEE 25 2 2 DS-3M 115 818 3XF25R 420 (191) WS11 RT18P11F25CUEE 2 37.5 2 2 DS-3M 115 818 3XF37R 450 (204) WS11 RT18P11F37CUEE 2 50 2 2 DS-3M 115 819 3XF50R 703 (319) WS16 RT18P11F50CUEE 75 2 2 DS-3M 115 820 3XF75R 793 (360) WS16 RT18P11F75CUEE 100 2 2 DS-3M 115 821 3XF100R 1085 (493) WS13 RT18P11F99CUEE 2 2 Full Capacity Taps 2 600 Volts to 120/240 Volts—Copper Windings 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DS-3M 115 816 262B15R 275 (125) WS11 RT60M11F15CUEE 2 25 2 at +2.5% 4 at –2.5% DS-3M 115 818 262B25R 440 (200) WS11 RT60M11F25CUEE 37.5 2 at +2.5% 4 at –2.5% DS-3M 115 818 262B37R 480 (218) WS11 RT60M11F37CUEE 2 50 2 at +2.5% 4 at –2.5% DS-3M 115 819 262B50R 725 (329) WS16 RT60M11F50CUEE 75 1 at +5% 2 at –5% DS-3M 115 820 262B75R 820 (372) WS16 RT60M11F75CUEE 2 100 1 at +5% 2 at –5% DS-3M 115 821 262B100R 1150 (522) WS13 RT60M11F99CUEE Full Capacity Taps 2 Notes 1 Suitable for installation in onshore, onboard or offshore applications. 2 1 at +5%, 2 at –5% at 208 volts primary; 2 at +2.5%, 4 at –2.5% at 416 volts primary. 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-136 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.5 Transformers Distribution Transformers Three-Phase—Type EPTM Marine Duty Encapsulated NEMA 3R, 60 Hz 2 2 480 Delta Volts to 208Y/120 Volts—Copper Windings Full Capacity Taps kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 None 2 at –5% EPTM 115 FR201 70A 132 (60) — LY48G28T03CU 1 6 None 2 at –5% EPTM 115 FR200 70A 182 (83) — LY48G28T06CU 1 9 2 at +2.5% 2 at –2.5% EPTM 115 FR103 72B 221 (100) — LY48D28T09CU 1 15 2 at +2.5% 2 at –2.5% EPTM 115 FR95 72B 296 (135) — LY48D28T15CU 1 30 2 at +2.5% 4 at –2.5% EPTM 115 FR243 84A 612 (278) — LY48M28T30CU 45 2 at +2.5% 4 at –2.5% EPTM 115 FR244 84A 808 (367) — LY48M28T45CU 75 2 at +2.5% 4 at –2.5% EPTM 115 FR245 84A 1450 (659) — LY48M28T75CU 2 2 2 2 2 2 2 480 Delta Volts to 240 Delta Volts—Copper Windings Full Capacity Taps kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 3 None 2 at –5% EPTM 115 FR201 74A 132 (60) — LY48G24T03CU 1 6 None 2 at –5% EPTM 115 FR200 74A 182 (83) — LY48G24T06CU 1 9 None 2 at –5% EPTM 115 FR103 74A 221 (100) — LY48G24T09CU 1 15 2 at +2.5% 2 at –2.5% EPTM 115 FR243 230A 612 (278) — LY48D24T15CU 1 2 2 2 Three-Phase—Type DT-3M Marine Duty Ventilated NEMA 2, 60 Hz (NEMA 3R with Weathershield Kit Installed) 2 2 480 Delta Volts to 208Y/120 Volts—Copper Windings 2 Full Capacity Taps 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280B15M 252 (114) WS38 MV48M28F15CU 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280B30M 299 (136) WS38 MV48M28F30CU 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280B45M 414 (188) WS38 MV48M28F45CU 75 2 at +2.5% 4 at –2.5% DT-3M 115 915F 280B75M 662 (301) WS39 MV48M28F75CU 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280B112M 927 (421) WS19 MV48M28F12CU 150 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280B49M 994 (451) WS19 MV48M28F49CU 225 2 at +2.5% 4 at –2.5% DT-3M 115 917 280B22M 1839 (835) WS34 MV48M28F22CU 300 2 at +2.5% 4 at –2.5% DT-3M 115 918A 280B33M 2134 (969) WS34 MV48M28F33CU 500 2 at +2.5% 2 at –2.5% DT-3M 115 919E 275A55M 3349 (1520) WS35 MV48M28F55CU 15 2 at +2.5% 4 at –2.5% DT-3M 80 912D 280B15M 295 (134) WS38 MV48M28B15CU 30 2 at +2.5% 4 at –2.5% DT-3M 80 912D 280B30M 367 (167) WS38 MV48M28B30CU 45 2 at +2.5% 4 at –2.5% DT-3M 80 915F 280B45M 585 (266) WS39 MV48M28B45CU 75 2 at +2.5% 4 at –2.5% DT-3M 80 916A 280B75M 903 (410) WS19 MV48M28B75CU 112.5 2 at +2.5% 4 at –2.5% DT-3M 80 916A 280B112M 959 (435) WS19 MV48M28B12CU 150 2 at +2.5% 4 at –2.5% DT-3M 80 917 280B49M 1250 (568) WS34 MV48M28B49CU 225 2 at +2.5% 4 at –2.5% DT-3M 80 918A 280B22M 1861 (845) WS34 MV48M28B22CU 300 2 at +2.5% 4 at –2.5% DT-3M 80 919E 280B33M 3600 (1634) WS19 MV48M28B33CU Notes 1 T-T (Scott T) connected secondary. 2 Not suitable for installation on U.S. or U.S. territory soil. Suitable for offshore or onboard applications. 2 2 2 2 2 2 2 2 2 2 2 2 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-137 2.5 2 Transformers Distribution Transformers Three-Phase—Type DT-3M Marine Duty Ventilated NEMA 2, 60 Hz (NEMA 3R with Weathershield Kit Installed) 2 480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap—Copper Windings 1 2 kVA 2 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 282B15M 252 (114) WS38 MV48M22F15CU 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 282B30M 301 (137) WS38 MV48M22F30CU 2 2 2 2 2 Full Capacity Taps FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 282B45M 382 (173) WS38 MV48M22F45CU 75 2 at +2.5% 4 at –2.5% DT-3M 115 915F 282B75M 550 (250) WS39 MV48M22F75CU 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 282B112M 675 (306) WS19 MV48M22F12CU 150 2 at +2.5% 4 at –2.5% DT-3M 115 916A 282B49M 860 (390) WS19 MV48M22F49CU MV48M22F22CU 225 2 at +2.5% 4 at –2.5% DT-3M 115 917 282B22M 1839 (835) WS34 300 2 at +2.5% 4 at –2.5% DT-3M 115 918A 282B33M 2134 (969) WS34 MV48M22F33CU 500 2 at +2.5% 2 at –2.5% DT-3M 115 919E 293A55M 3349 (1520) WS35 MV48D22F55CU 2 480 Delta Volts to 120 Delta Volts—Copper Windings 1 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 295B15M 252 (114) WS38 MV48M12F15CU 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 295B30M 301 (137) WS38 MV48M12F30CU 2 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 295B45M 382 (173) WS38 MV48M12F45CU 75 2 at +2.5% 4 at –2.5% DT-3M 115 915F 295B75M 550 (250) WS39 MV48M12F75CU Full Capacity Taps 2 2 Three-Phase—Type DT-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 2 208 Delta Volts to 208Y/120 Volts—Copper Windings 2 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280E15M 265 (120) WS38 MV29M28F15CUEE 2 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280E30M 475 (215) WS38 MV29M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280E45M 475 (216) WS38 MV29M28F45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 280E75M 700 (318) WS39 MV29M28F75CUEE 112.5 1 at +5% 2 at –5% DT-3M 115 916A 280E112M 935 (424) WS19 MV29M28F12CUEE 2 150 1 at +5% 2 at –5% DT-3M 115 916A 280E150M 1274 (578) WS19 MV29M28F49CUEE 2 225 1 at +5% 2 at –5% DT-3M 115 917 280E225M 1743 (791) WS34 MV29M28F22CUEE 300 1 at +5% 2 at –5% DT-3M 115 919E 280E300M 2350 (1067) WS35 MV29M28F33CUEE 500 1 at +5% 2 at –5% DT-3M 115 920E 280E500M 3690 (1675) WS35 MV29M28F55CUEE 2 2 2 2 Full Capacity Taps Notes 1 Not suitable for installation on U.S. or U.S. territory soil. Suitable for offshore or onboard applications. 2 Suitable for installation in onshore, onboard or offshore applications. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 V2-T2-138 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.5 Transformers Distribution Transformers Three-Phase—Type DT-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1 2 2 208 Delta Volts to 480Y/277 Volts—Copper Windings Full Capacity Taps kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 342B15M 265 (120) WS38 MV29M47F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 342B30M 475 (215) WS38 MV29M47F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 342B45M 475 (216) WS38 MV29M47F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 342B75M 700 (318) WS39 MV29M47F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 342B112M 935 (424) WS19 MV29M47F12CUEE 150 1 at +5% 2 at –5% DT-3M 115 916A 351A150M 1274 (578) WS19 MV29R47F49CUEE 225 1 at +5% 2 at –5% DT-3M 115 917 333B225M 1743 (791) WS34 MV29R47F22CUEE 300 1 at +5% 2 at –5% DT-3M 115 919E 333B300M 2350 (1067) WS35 MV29R47F33CUEE 500 1 at +5% 2 at –5% DT-3M 115 920E 333B500M 3690 (1675) WS35 MV29R47F55CUEE Weight Lbs (kg) Weathershield Catalog Number 2 2 2 2 2 2 2 240 Delta Volts to 208Y/120 Volts—Copper Windings Full Capacity Taps 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280C15M 265 (120) WS38 MV24M28F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280C30M 475 (215) WS38 MV24M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280C45M 475 (216) WS38 MV24M28F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 280C75M 700 (318) WS39 MV24M28F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280C112M 1009 (458) WS19 MV24M28F12CUEE 150 1 at +5% 2 at –5% DT-3M 115 916A 289A150M 1274 (578) WS19 MV24R28F49CUEE 225 1 at +5% 2 at –5% DT-3M 115 917 289A225M 1743 (791) WS34 MV24R28F22CUEE 300 1 at +5% 2 at –5% DT-3M 115 919E 289A300M 2350 (1067) WS35 MV24R28F33CUEE 500 1 at +5% 2 at –5% DT-3M 115 920E 289A500M 3690 (1675) WS35 MV24R28F55CUEE 2 2 2 2 2 2 2 240 Delta Volts to 480Y/277 Volts—Copper Windings Full Capacity Taps Weight Lbs (kg) 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 342L15M 265 (120) WS38 MV24M47F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 342L30M 475 (215) WS38 MV24M47F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 342L45M 475 (216) WS38 MV24M47F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 342L75M 700 (318) WS39 MV24M47F75CUEE 112.5 1 at +5% 2 at –5% DT-3M 115 916A 351C112M 1009 (458) WS19 MV24R47F12CUEE 150 1 at +5% 2 at –5% DT-3M 115 916A 351C150M 1274 (578) WS19 MV24R47F49CUEE 225 1 at +5% 2 at –5% DT-3M 115 917 333A225M 1743 (791) WS34 MV24R47F22CUEE 300 1 at +5% 2 at –5% DT-3M 115 919E 333A300M 2350 (1067) WS35 MV24R47F33CUEE 500 1 at +5% 2 at –5% DT-3M 115 920E 333A500M 3690 (1675) WS35 MV24R47F55CUEE 2 2 2 2 2 2 Notes 1 Suitable for installation in onshore, onboard or offshore applications. 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-139 2.5 2 Transformers Distribution Transformers Three-Phase—Type DT-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1 2 440 Delta Volts to 220Y/127 Volts—Copper Windings 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280J15M 256 (116) WS38 MV44M31F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280J30M 337 (153) WS38 MV44M31F30CUEE 2 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280J45M 446 (202) WS38 MV44M31F45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 280J75M 662 (301) WS39 MV44M31F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280J112M 914 (415) WS19 MV44M31F12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280J150M 1132 (514) WS19 MV44M31F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3M 115 917 280J225M 2036 (924) WS34 MV44M31F22CUEE 2 300 2 at +2.5% 4 at –2.5% DT-3M 115 923 275F300M 2325 (1056) WS37 MV44M31F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3M 115 919E 275F500M 3681 (1671) WS35 MV44M31F55CUEE 2 2 Full Capacity Taps 2 480 Delta Volts to 208Y/120 Volts—Copper Windings 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280B15M 256 (116) WS38 MV48M28F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280B30M 337 (153) WS38 MV48M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280B45M 446 (202) WS38 MV48M28F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 280B75M 662 (301) WS39 MV48M28F75CUEE 2 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280B112M 914 (415) WS19 MV48M28F12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280B150M 1132 (514) WS19 MV48M28F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3M 115 917 275A225M 2036 (924) WS34 MV48M28F22CUEE 2 2 2 Full Capacity Taps 300 2 at +2.5% 4 at –2.5% DT-3M 115 923 275A300M 2325 (1056) WS37 MV48M28F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3M 115 919E 275A500M 3681 (1671) WS35 MV48M28F55CUEE 2 2 480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 2—Copper Windings 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 282B15M 248 (113) WS38 MV48M22F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 282B30M 410 (186) WS38 MV48M22F30CUEE 2 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 282B45M 445 (202) WS38 MV48M22F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 282B75M 750 (341) WS39 MV48M22F75CUEE 2 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 282B112M 963 (437) WS19 MV48M22F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3M 115 916A 282B150M 1236 (561) WS19 MV48M22F49CUEE 2 225 2 at +2.5% 4 at –2.5% DT-3M 115 917 282B225M 2100 (953) WS34 MV48M22F22CUEE 2 300 2 at +2.5% 4 at –2.5% DT-3M 115 923 282B300M 2600 (1180) WS37 MV48M22F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3M 115 919E 291A500M 3700 (1680) WS35 MV48M22F55CUEE 2 2 Full Capacity Taps Notes 1 Suitable for installation in onshore, onboard or offshore applications. 2 Lighting tap limited to 5% of nameplate full load capacity. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 V2-T2-140 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.5 Transformers Distribution Transformers Three-Phase—Type DT-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1 2 2 480 Delta Volts to 480Y/277 Volts—Copper Windings Full Capacity Taps kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280B15M 258 (117) WS38 MV48M47F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280B30M 401 (182) WS38 MV48M47F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280B45M 455 (207) WS38 MV48M47F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 280B75M 678 (308) WS39 MV48M47F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280B112M 676 (307) WS19 MV48M47F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280B150M 1249 (567) WS19 MV48M47F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3M 115 917 275A225M 2107 (957) WS34 MV48M47F22CUEE 300 2 at +2.5% 4 at –2.5% DT-3M 115 923 275A300M 2418 (1098) WS37 MV48M47F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3M 115 919E 275A500M 3800 (1725) WS35 MV48M47F55CUEE Weight Lbs (kg) Weathershield Catalog Number 2 2 2 2 2 2 2 600 Delta Volts to 208Y/120 Volts—Copper Windings Full Capacity Taps 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280A15M 269 (122) WS38 MV60M28F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280A30M 354 (161) WS38 MV60M28F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280A45M 468 (213) WS38 MV60M28F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 280A75M 695 (316) WS39 MV60M28F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280A112M 960 (436) WS19 MV60M28F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280A150M 1189 (540) WS19 MV60M28F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3M 115 917 280A225M 2138 (971) WS34 MV60M28F22CUEE 300 2 at +2.5% 4 at –2.5% DT-3M 115 923 280A300M 2441 (1108) WS37 MV60M28F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3M 115 919E 280A500M 3865 (1755) WS35 MV60M28F55CUEE 2 2 2 2 2 2 2 600 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 2—Copper Windings Full Capacity Taps Weight Lbs (kg) 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weathershield Catalog Number 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 282B15M 269 (122) WS38 MV60M22F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 282B30M 354 (161) WS38 MV60M22F30CUEE 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 282B45M 468 (213) WS38 MV60M22F45CUEE 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 282B75M 695 (316) WS39 MV60M22F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 282B112M 960 (436) WS19 MV60M22F12CUEE 150 2 at +2.5% 4 at –2.5% DT-3M 115 916A 282B150M 1189 (540) WS19 MV60M22F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3M 115 917 282B225M 2138 (971) WS34 MV60M22F22CUEE 300 2 at +2.5% 4 at –2.5% DT-3M 115 923 282B300M 2441 (1108) WS37 MV60M22F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3M 115 919E 291A500M 3865 (1755) WS35 MV60M22F55CUEE 2 2 2 2 2 2 2 Notes 1 Suitable for installation in onshore, onboard or offshore applications. 2 Lighting tap limited to 5% of nameplate full load capacity. 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-141 2.5 2 Transformers Distribution Transformers Three-Phase—Type DT-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1 2 600 Delta Volts to 480Y/277 Volts—Copper Windings 2 kVA FCAN FCBN Type °C Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 15 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280A15M 284 (129) WS38 MV60M47F15CUEE 30 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280A30M 441 (200) WS38 MV60M47F30CUEE 2 45 2 at +2.5% 4 at –2.5% DT-3M 115 912D 280A45M 501 (227) WS38 MV60M47F45CUEE 2 75 2 at +2.5% 4 at –2.5% DT-3M 115 914F 280A75M 746 (339) WS39 MV60M47F75CUEE 112.5 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280A112M 744 (338) WS19 MV60M47F12CUEE 2 150 2 at +2.5% 4 at –2.5% DT-3M 115 916A 280A150M 1374 (624) WS19 MV60M47F49CUEE 225 2 at +2.5% 4 at –2.5% DT-3M 115 917 280A225M 2318 (1052) WS34 MV60M47F22CUEE 2 300 2 at +2.5% 4 at –2.5% DT-3M 115 923 280A300M 2660 (1208) WS37 MV60M47F33CUEE 500 2 at +2.5% 4 at –2.5% DT-3M 115 919E 280A500M 4180 (1898) WS35 MV60M47F55CUEE 2 2 Full Capacity Taps Notes 1 Suitable for installation in onshore, onboard or offshore applications. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-142 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.5 Transformers Distribution Transformers Accessories Please refer to Section 2.7 Page V2-T2-191. 2 Technical Data and Specifications 2 Frequency Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour, and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 40°C 80°C 30°C 150°C 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C 40°C 150°C 30°C 220°C The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. Enclosures Eaton ventilated transformers Types DS-3M and DT-3M use a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Eaton encapsulated transformers Types EPM and EPTM use a NEMA 3R rated enclosure. Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Ventilated transformers have leads brought out to aluminum pads that are predrilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. Eaton recommends that external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Series-Multiple Windings Series-multiple windings consist of two similar coils in each winding that can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with an “x” or “/” between the voltage ratings, such as voltages of “120/240” or “240 x 480.” If the seriesmultiple winding is designated by an “x,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 x 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), 240 (series) or 240 with a 120 mid-point. 2 Sound Levels All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. For additional information, please refer to Section 2.7 Page V2-T2-195. 2 2 2 2 2 2 2 Average Sound Levels NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) K-Factor 1, 4, 9 K-Factor 13, 20 kVA Range Encapsulated (up to 1.2 kV) 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 50.01 to 75.00 50 53 55 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 500.01 to 700.00 62 65 61 2 2 2 2 2 2 2 2 2 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-143 2.5 2 Transformers Distribution Transformers Contents Type EP Description 2 Page Motor Drive Isolation Transformers. . . . . . . . . . . . Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers . . . Class I, Division 2, Hazardous Location Transformers Open-Type Core and Coil Assembly Transformers Marine Duty Transformers . . . . . . . . . . . . . . . . . . Buck-Boost and Low Voltage Lighting Transformers Product Selection. . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . Medium Voltage Distribution Transformers. . . . . . 2 2 2 2 2 2 V2-T2-111 V2-T2-119 V2-T2-124 V2-T2-127 V2-T2-130 V2-T2-133 V2-T2-145 V2-T2-171 V2-T2-171 V2-T2-172 V2-T2-173 2 2 2 Buck-Boost and Low Voltage Lighting Transformers 2 Product Description 2 2 2 2 2 2 2 2 2 2 2 2 Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Types EP, EPT ● Encapsulated design ● Suitable for indoor or outdoor applications ● Totally enclosed, nonventilated enclosures ● Enclosures are NEMA 3R rated ● Mountable in any position indoors and upright-only outdoors ● 180ºC insulation system ● 115°C rise standard; 80°C rise optional ● Available in single-phase ratings through 7.5 kVA Application Description A buck-boost transformer is used to provide an economical method of correcting a lower or higher voltage rating more suitable for efficient operation of electrical equipment. Type EP buck-boost transformers are small kVA, single-phase transformers with dual primary and dual secondary windings, and are usually connected as autotransformers by using one unit for single-phase applications and either two or three units banked for threephase operation. They are primarily used for motor operation and should not be used for motor control circuits, to correct fluctuating line voltage or to obtain a neutral on a delta system. Buck-boost transformers are ideally suited for use with low voltage lighting systems, such as outdoor lighting. Features, Benefits and Functions ● ● ● ● 60 Hz operation 600 volt class insulation Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels Standards and Certifications ● ● UL listed CSA certified Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Eaton-manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the International Building Code (IBC) and California Code Title 24. Catalog Number Selection 2 Please refer to Section 2.7 Page V2-T2-187. 2 2 2 2 2 V2-T2-144 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers Product Selection For quick selection data, refer to the tables on this and the following pages. Selection Requirements You should have the following information before selecting a buck-boost transformer: Line Voltage The voltage that you want to buck (decrease) or boost (increase). This can be found by measuring the supply line voltage with a voltmeter. Load Voltage The voltage at which your equipment is designed to operate. This is listed on the nameplate of the load equipment. Load Amperes or Load kVA You do not need to know both—one or the other is sufficient for selection purposes. This information usually can be found on the nameplate of the equipment that you want to operate. Frequency The supply line frequency must be the same as the frequency of the equipment to be operated—Eaton’s buck-boost transformers operate at 60 Hz only. Phase The supply line should be the same as the equipment to be operated—either singleor three-phase. Transformer Interconnection For three-phase applications, interconnections of transformers should be made in a junction box. Two or three transformers may be used depending on an open delta (2) or wye (3) connection. 2.5 120 x 240 Volts to 12/24 Volts 5-Step Selector The tables that follow will simplify the selection of the buck-boost transformers. There are no calculations needed; simply follow these five steps: 1. Refer to the table having the same output voltage as the equipment you want to operate. For example, if you are installing a 240 volt 6 kVA single-phase load use selection table on the page. 2. Select the available line voltage across the top of the chart that is closest to the actual supply voltage. Therefore, for example, if the available line voltage is 213 volts, use the 212 volt column. 3. Read down the column until you reach an output kVA or amps rating equal to or greater than the load requirements. Since 6 kVA, in the example, is not listed, use the next higher rating, or 7.5 kVA. 4. Read across to the far left columns for the catalog number and quantity of transformers for your application. In this case, you will need one (1) catalog number S10N06P01P. 5. Connect the buck-boost transformer(s) you have selected in accordance with the connection diagram specified at the bottom of the available line voltage column. In this example, Diagram “F” would be used. Note: For single-phase connections and three-phase open delta connections, inputs and outputs may be reversed. kVA capacity remains constant. Additional Product Selection information begins on Page V2-T2-189. kVA °C Temp. Rise Frame Weight Lbs (kg) Catalog Number 0.05 115 FR52 7 (3) S10N04A81N 0.10 115 FR54 7 (3) S10N04A82N 0.15 115 FR55 8 (4) S10N04A83N 0.25 115 FR57P 12 (5) S10N04P26P 0.50 115 FR57P 13 (5) S10N04P51P 0.75 115 FR58AP 21 (10) S10N04P76P 1 115 FR67P 31 (14) S10N04P01P 1.5 115 FR67P 40 (18) S10N04P16P 2 115 FR68P 40 (18) S10N04P02P 3 115 FR176 65 (29) S10N04A03N 5 115 FR177 113 (51) S10N04A05N 7.5 115 FR178 123 (55) S10N04A07N 2 2 2 2 2 2 2 2 2 120 x 240 Volts to 16/32 Volts kVA °C Temp. Rise Frame Weight Lbs (kg) Catalog Number 0.05 115 FR52 7 (3) S10N06A81N 0.10 115 FR54 7 (3) S10N06A82N 0.15 115 FR55 8 (4) S10N06A83N 0.25 115 FR57P 12 (5) S10N06P26P 0.50 115 FR57P 13 (5) S10N06P51P 0.75 115 FR58AP 21 (10) S10N06P76P 1 115 FR67P 31 (14) S10N06P01P 1.5 115 FR67P 40 (18) S10N06P16P 2 115 FR68P 40 (18) S10N06P02P 3 115 FR176 65 (29) S10N06A03N 5 115 FR177 113 (51) S10N06A05N 7.5 115 FR178 123 (55) S10N06A07N 2 2 2 2 2 2 2 2 2 240 x 480 Volts to 24/48 Volts kVA °C Temp. Rise Frame Weight Lbs (kg) Catalog Number 0.05 115 FR52 7 (3) S20N08A81N 0.10 115 FR54 7 (3) S20N08A82N 0.15 115 FR55 8 (4) S20N08A83N 0.25 115 FR57P 12 (5) S20N08P26P 0.50 115 FR57P 13 (5) S20N08P51P 0.75 115 FR58AP 21 (10) S20N08P76P 1 115 FR67P 31 (14) S20N08P01P 1.5 115 FR67P 40 (18) S20N08P16P 2 115 FR68P 40 (18) S20N08P02P 3 115 FR176 65 (29) S20N08A03N 5 115 FR177 113 (51) S20N08A05N 7.5 115 FR178 123 (55) S20N08A07N Note Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-145 2.5 Transformers Distribution Transformers 2 Single-Phase 115 Volt Output Required, 60 Hz 2 84 91 96 100 Output Output Output Input Available Voltage 102 Units Required 1 Unit kVA Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 1 0.05 — — — — 0.24 2.09 — — — — S10N04A81N 2 1 0.05 0.13 1.14 0.18 1.56 — — 0.31 2.70 0.36 3.13 S10N06A81N 2 1 0.10 — — — — 0.48 4.17 — — — — S10N04A82N 1 0.10 0.26 2.29 0.36 3.12 — — 0.62 5.41 0.72 6.25 S10N06A82N 2 1 0.15 — — — — 0.72 6.25 — — — — S10N04A83N 1 0.15 0.39 3.44 0.54 4.69 — — 0.93 8.12 1.08 9.37 S10N06A83N 2 1 0.25 — — — — 1.2 10.4 — — — — S10N04P26P 2 1 0.25 0.659 5.73 0.899 7.81 — — 1.56 13.5 1.8 15.6 S10N06P26P 1 0.50 — — — — 2.4 20.8 — — — — S10N04P51P 2 1 0.50 1.32 11.5 1.8 15.6 — — 3.11 27.1 3.59 31.2 S10N06P51P 1 0.75 — — — — 3.6 31.2 — — — — S10N04P76P 2 1 0.75 1.98 17.2 2.7 23.4 — — 4.67 40.6 5.39 46.8 S10N06P76P 1 1 — — — — 4.79 41.7 — — — — S10N04P01P 2 1 1 2.64 22.9 3.59 31.2 — — 6.23 54.1 7.19 62.5 S10N06P01P 2 1 1.5 — — — — 7.2 62.5 — — — — S10N04P16P 1 1.5 3.95 34.4 5.39 46.9 — — 9.34 81.2 10.8 93.7 S10N06P16P 2 1 2 — — — — 9.58 83.3 — — — — S10N04P02P 1 2 5.27 45.8 7.19 62.5 — — 12.5 108 14.4 125 S10N06P02P 2 1 3 — — — — 14.37 125.1 — — — — S10N04A03N 1 3 7.92 68.7 10.77 93.6 — — 18.69 162.3 21.57 187.5 S10N06A03N 2 1 5 — — — — 23.95 208.5 — — — — S10N04A05N 2 1 5 13.2 115 18 156 — — 31.15 270.5 35.95 312.5 S10N06A05N 1 7.5 — — — — 36 312 — — — — S10N04A07N 1 7.5 19.8 172 27 234 — — 46.7 406 53.9 468 S10N06A07N 2 2 2 2 2 2 Connection Diagram 2 D B B C Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-146 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Output A Transformers Distribution Transformers 2.5 Single-Phase 115 Volt Output Required, 60 Hz 2 Input Available Voltage 2 105 127 130 138 Units Required 1 Unit kVA Output Output Output Output 146 kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 1 0.05 0.48 4.17 0.54 4.58 — — 0.29 2.5 — — S10N04A81N 1 0.05 — — — — 0.41 3.54 — — 0.23 1.98 S10N06A81N 1 0.10 0.96 8.33 1.1 9.17 — — 0.58 5.0 — — S10N04A82N 1 0.10 — — — — 0.82 7.08 — — 0.46 3.95 S10N06A82N 1 0.15 1.44 12.5 1.6 13.7 — — 0.87 7.5 — — S10N04A83N 1 0.15 — — — — 1.3 10.6 — — 0.69 5.93 S10N06A83N 1 0.25 2.39 20.8 2.63 22.9 — — 1.44 12.5 — — S10N04P26P 1 0.25 — — — — 2.03 17.7 — — 1.14 9.88 S10N06P26P 1 0.50 4.79 41.6 5.27 45.8 — — 2.87 25 — — S10N04P51P 1 0.50 —— — — — 4.07 35.4 — — 2.27 19.8 S10N06P51P 1 0.75 7.19 62.4 7.9 68.7 — — 4.31 37.5 — — S10N04P76P 1 0.75 — — — — 6.1 53.1 — — 3.41 29.6 S10N06P76P 1 1 9.58 83.3 10.5 91.7 — — 5.75 50 — — S10N04P01P 1 1 — — — — 8.14 70.8 — — 4.55 39.5 S10N06P01P 1 1.5 14.4 125 15.8 137 — — 8.62 75 — — S10N04P16P Output 1 1.5 — — — — 12.2 106 — — 6.82 59.3 S10N06P16P 1 2 19.2 16.7 21.1 183 — — 11.5 100 — — S10N04P02P 1 2 — — — — 16.3 142 — — 9.10 79.2 S10N06P02P 1 3 28.7 249.9 31.5 275.1 — — 17.3 150 — — S10N04A03N 1 3 — — — — 24.4 212.4 — — 13.6 118.5 S10N06A03N 1 5 47.9 416.5 52.5 458.5 — — 28.7 250 — — S10N04A05N 1 5 — — — — 40.7 354 — — 22.7 197.5 S10N06A05N 1 7.5 71.9 624 79 687 — — 43.1 357 — — S10N04A07N 1 7.5 — — — — 61 531 — — 34.1 296 S10N06A07N Connection Diagram 2 A A A B B 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-147 2.5 2 2 Transformers Distribution Transformers Single-Phase 120 Volt Output Required, 60 Hz Input Available Voltage 88 95 100 104 106 Units Required 1 Unit kVA Output Output Output Output Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 1 0.05 — — — — 0.25 2.09 — — — — S10N04A81N 2 1 0.05 0.14 1.15 0.19 1.56 — — 0.33 2.70 0.38 3.13 S10N06A81N 2 1 0.10 — — — — 0.50 4.17 — — — — S10N04A82N 1 0.10 0.28 2.29 0.38 3.12 — — 0.65 5.41 0.75 6.25 S10N06A82N 2 1 0.15 — — — — 0.75 6.25 — — — — S10N04A83N 1 0.15 0.41 3.44 0.56 4.69 — — 0.98 8.12 1.12 9.37 S10N06A83N 2 1 0.25 — — — — 1.25 10.4 — — — — S10N04P26P 2 1 0.25 0.687 5.73 0.937 7.81 — — 1.62 13.5 1.87 15.6 S10N06P26P 1 0.50 — — — — 2.5 20.8 — — — — S10N04P51P 2 1 0.50 1.37 11.5 1.87 15.6 — — 3.25 27.1 3.75 31.2 S10N06P51P 1 0.75 — — — — 3.75 31.2 — — — — S10N04P76P 2 1 0.75 2.06 17.2 2.82 23.4 — — 4.87 40.6 5.62 46.8 S10N06P76P 1 1 — — — — 5 41.7 — —— — — S10N04P01P 2 1 1 2.75 22.9 3.75 31.2 — — 6.5 54.1 7.5 62.5 S10N06P01P 2 1 1.5 — — — — 7.5 62.5 — — — — S10N04P16P 1 1.5 4.12 34.4 5.62 46.9 — — 9.75 81.2 11.2 93.7 S10N06P16P 2 1 2 — — — — 10 83.3 — — — — S10N04P02P 1 2 5.5 45.8 7.5 62.5 — — 13 108 15 125 S10N06P02P 2 1 3 — — — — 15 125.1 — — — — S10N04A03N 1 3 8.25 68.7 11.25 93.6 — — 19.5 162.3 22.5 187.5 S10N06A03N 2 1 5 — — — — 25 208.5 — — — — S10N04A05N 2 1 5 13.75 114.5 18.75 156 — — 32.5 270.5 37.5 312.5 S10N06A05N 1 7.5 — — — — 37.5 312 — — — — S10N04A07N 1 7.5 20.6 172 28.2 234 — — 48.7 406 56.2 468 S10N06A07N 2 2 2 2 2 2 Connection Diagram 2 D B B C Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-148 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com A Transformers Distribution Transformers 2.5 Single-Phase 120 Volt Output Required, 60 Hz 2 Input Available Voltage 2 109 132 136 144 Units Required 1 Unit kVA Output Output Output Output 152 kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 1 0.05 0.5 4.17 0.55 4.58 — — 0.3 2.5 — — S10N04A81N Output 1 0.05 — — — — 0.43 3.54 — — 0.24 1.98 S10N06A81N 1 0.10 1.0 8.33 1.1 9.17 — — 0.6 5.0 — — S10N04A82N 1 0.10 — — — — 0.85 7.08 — — 0.48 3.95 S10N06A82N 1 0.15 1.5 12.5 1.6 13.7 — — 0.9 7.5 — — S10N04A83N 1 0.15 — — — — 1.27 10.6 — — 0.71 5.93 S10N06A83N 1 0.25 2.5 20.8 2.75 22.9 — — 1.5 12.5 — — S10N04P26P 1 0.25 — — — — 2.12 17.7 — — 1.19 9.88 S10N06P26P 1 0.50 5 41.6 5.5 45.8 — — 3 25 — — S10N04P51P 1 0.50 — — — — 4.25 35.4 — — 2.37 19.8 S10N06P51P 1 0.75 7.5 62.4 8.25 68.7 — — 4.5 37.5 — — S10N04P76P 1 0.75 — — — — 6.37 53.1 — — 3.56 29.6 S10N06P76P 1 1 10 83.3 11 91.7 — — 6 50 — — S10N04P01P 1 1 — — — — 8.5 70.8 — — 4.75 39.5 S10N06P01P 1 1.5 15 125 16.5 137 — — 9 75 — — S10N04P16P 1 1.5 — — — — 12.7 106 — — 7.12 59.3 S10N06P16P 1 2 20 167 22 183 — — 12 100 — — S10N04P02P 1 2 — — — — 17 142 — — 9.5 79.2 S10N06P02P 1 3 30 249.9 33 275.1 — — 18 150 — — S10N04A03N 1 3 — — — — 25.5 212.4 — — 14.25 118.5 S10N06A03N 1 5 50 416.5 55 458.5 — — 30 250 — — S10N04A05N 1 5 — — — — 42.5 354 — — 23.7 197.5 S10N06A05N 1 7.5 75 624 82.5 687 — — 45 375 — — S10N04A07N 1 7.5 — — — — 63.7 531 — — 35.6 296 S10N06A07N Connection Diagram 2 A A A B B 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-149 2.5 Transformers Distribution Transformers 2 Single-Phase 230 Volt Output Required, 60 Hz 2 199 203 207 209 216 Output Output Output Output Input Available Voltage Units Required 1 Unit kVA Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 1 0.05 — — — — 0.43 1.88 0.48 2.08 — — S10N04A81N 2 1 0.05 0.31 1.36 0.36 1.56 — — — — 0.72 3.12 S10N06A81N 2 1 0.10 — — — — 0.86 3.75 0.96 4.17 — — S10N04A82N 1 0.10 0.62 2.71 0.72 3.12 — — — — 1.44 6.25 S10N06A82N 2 1 0.15 — — — — 1.29 5.62 1.44 6.25 — — S10N04A83N 1 0.15 0.93 4.06 1.08 4.69 — — — — 2.16 9.37 S10N06A83N 2 1 0.25 — — — — 2.15 9.37 2.39 10.4 — — S10N04P26P 2 1 0.25 1.55 6.77 1.8 7.81 — — — — 3.59 15.6 S10N06P26P 1 0.50 — — — — 4.31 18.7 4.79 20.8 — — S10N04P51P 2 1 0.50 3.11 13.5 3.6 15.6 — — — — 7.19 31.2 S10N06P51P 1 0.75 — — — — 6.46 28.2 7.19 31.2 — — S10N04P76P 2 1 0.75 4.66 20.3 5.4 23.4 — — — — 10.8 46.8 S10N06P76P 1 1 — — — — 8.62 37.5 9.58 41.7 — — S10N04P01P 2 1 1 6.23 27.1 7.2 31.2 — — — — 14.4 62.5 S10N06P01P 2 1 1.5 — — — — 12.9 56.2 14.4 62.5 — — S10N04P16P 1 1.5 9.34 40.6 10.8 46.9 — — — — 21.6 93.7 S10N06P16P 2 1 2 — — — — 17.2 75 19.2 83.3 — — S10N04P02P 1 2 12.5 54.2 14.4 62.5 — — — — 28.7 125 S10N06P02P 2 1 3 — — — — 25.8 112.5 28.7 125.1 — — S10N04A03N 1 3 18.6 81.3 21.6 93.6 — — — — 43.2 187.5 S10N06A03N 2 1 5 — — — — 43.1 187.5 47.9 208.5 — — S10N04A05N 2 1 5 31.1 135.5 36 156 — — — — 72 312.5 S10N06A05N 1 7.5 — — — — 64.6 282 71.9 312 — — S10N04A07N 1 7.5 46.6 203 54 234 — — — — 108 468 S10N06A07N 2 2 2 2 2 2 Connection Diagram 2 G F G F Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-150 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com E Transformers Distribution Transformers 2.5 Single-Phase 230 Volt Output Required, 60 Hz 2 Input Available Voltage 2 219 242 246 253 Units Required 1 Unit kVA Output Output Output Output 260 kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 1 0.05 0.96 4.16 1.0 4.38 — — 0.53 2.29 — — S10N04A81N Output 1 0.05 — — — — 0.77 3.34 — — 0.41 1.77 S10N06A81N 1 0.10 1.92 8.33 2.01 8.75 — — 1.05 4.58 — — S10N04A82N 1 0.10 — — — — 1.53 6.67 — — 0.82 3.54 S10N06A82N 1 0.15 2.87 12.5 3.02 13.1 — — 1.58 6.87 — — S10N04A83N 1 0.15 — — — — 2.3 10.0 — — 1.22 5.31 S10N06A83N 1 0.25 4.79 20.8 5.03 21.9 — — 2.63 11.5 — — S10N04P26P 1 0.25 — — — — 3.83 16.7 — — 2.04 8.85 S10N06P26P 1 0.50 9.58 41.6 10.1 43.7 — — 5.27 22.9 — — S10N04P51P 1 0.50 — — — — 7.67 33.3 — — 4.07 17.7 S10N06P51P 1 0.75 14.4 62.4 15.1 65.6 — — 7.9 34.4 — — S10N04P76P 1 0.75 — — — — 11.5 50 — — 6.11 26.6 S10N06P76P 1 1 19.2 83.3 20.1 87.5 — — 10.5 45.8 — — S10N04P01P 1 1 — — — — 15.3 66.7 — — 8.15 35.4 S10N06P01P 1 1.5 28.7 125 30.2 131 — — 15.8 68.7 — — S10N04P16P 1 1.5 — — — — 23 100 — — 12.2 53.1 S10N06P16P 1 2 38.3 167 40.2 175 — — 21.1 91.7 — — S10N04P02P 1 2 — — — — 30.7 133 — — 16.3 70.8 S10N06P02P 1 3 57.6 249.9 60.3 262.5 — — 31.5 137.4 — — S10N04A03N 1 3 — — — — 45.9 200.1 — — 24.4 106.2 S10N06A03N 1 5 96 416.5 100.5 437.5 — — 52.5 229 — — S10N04A05N 1 5 — — — — 76.5 333.5 — — 40.7 177 S10N06A05N 1 7.5 144 624 151 656 — — 79 344 — — S10N04A07N 1 7.5 — — — — 115 500 — — 61.1 266 S10N06A07N Connection Diagram 2 E E E F F 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-151 2.5 2 2 Transformers Distribution Transformers Single-Phase 240 Volt Output Required, 60 Hz Input Available Voltage 208 212 216 218 225 Units Required 1 Unit kVA Output Output Output Output Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 1 0.05 — — — — 0.45 1.88 0.5 2.08 — — S10N04A81N 2 1 0.05 0.32 1.35 0.38 1.56 — — — — 0.75 3.12 S10N06A81N 2 1 0.10 — — — — 0.9 3.75 1.0 4.17 — — S10N04A82N 1 0.10 0.65 2.71 0.75 3.12 — — — — 1.5 6.25 S10N06A82N 2 1 0.15 — — — — 1.35 5.62 1.5 6.25 — — S10N04A83N 1 0.15 0.98 4.06 1.12 4.69 — — — — 2.25 9.37 S10N06A83N 2 1 0.25 — — — — 2.25 9.37 2.5 10.4 — — S10N04P26P 2 1 0.25 1.62 6.77 1.87 7.81 — — — — 3.75 15.6 S10N06P26P 1 0.50 — — — — 4.5 18.7 5 20.8 — — S10N04P51P 2 1 0.50 3.25 13.5 3.75 15.6 — — — — 7.5 31.2 S10N06P51P 1 0.75 — — — — 6.75 28.2 7.5 31.2 — — S10N04P76P 2 1 0.75 4.87 20.3 5.62 23.4 — — — — 11.2 46.8 S10N06P76P 1 1 — — — — 9 37.5 10 41.7 — — S10N04P01P 2 1 1 6.5 27.1 7.5 31.2 — — — — 15 62.5 S10N06A01 2 1 1.5 — — — — 13.5 56.2 15 62.5 — — S10N04P16P 1 1.5 9.75 40.6 11.2 46.9 — — — — 22.5 93.7 S10N06P16P 2 1 2 — — — — 18 75 20 83.3 — — S10N04P02P 1 2 13 54.2 15 62.5 — — — — 30 125 S10N06P02P 2 1 3 — — — — 27 112.5 30 125.1 — — S10N04A03N 1 3 19.5 81.3 22.5 93.6 — — — — 45 187.5 S10N06A03N 2 1 5 — — — — 45 187 50 208 — — S10N04A05N 2 1 5 32.5 135 37.5 156 — — — — 75 312 S10N06A05N 1 7.5 — — — — 67.5 282 75 312 — — S10N04A07N 1 7.5 48.7 203 56.2 234 — — — — 112 468 S10N06A07N 2 2 2 2 2 2 Connection Diagram 2 G F G F Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-152 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com E Transformers Distribution Transformers 2.5 Single-Phase 240 Volt Output Required, 60 Hz 2 Input Available Voltage 2 229 252 256 264 Units Required 1 Unit kVA Output Output Output Output 272 kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 1 0.05 1.0 4.16 1.05 4.38 — — 0.55 2.29 — — S10N04A81N 1 0.05 — — — — 0.8 3.33 — — 0.42 1.77 S10N06A81N 1 0.10 2.0 8.33 2.1 8.75 — — 1.1 4.58 — — S10N04A82N 1 0.10 — — — — 1.6 6.67 — — 0.85 3.54 S10N06A82N 1 0.15 3.0 12.5 3.15 13.1 — — 1.65 6.87 — — S10N04A83N 1 0.15 — — — — 2.4 10.0 — — 1.27 5.31 S10N06A83N 1 0.25 5 20.8 5.25 21.9 — — 2.75 11.5 — — S10N04P26P 1 0.25 — — — — 4 16.7 — — 2.12 8.85 S10N06P26P 1 0.50 10 41.6 10.5 43.7 — — 5.5 22.9 — — S10N04P51P 1 0.50 — — — — 8 33.3 — — 4.25 17.7 S10N06P51P 1 0.75 15 62.4 15.7 65.6 — — 8.25 34.4 — — S10N04P76P 1 0.75 — — — — 12 50 — — 6.37 26.6 S10N06P76P 1 1 20 83.3 21 87.5 — — 11 45.8 — — S10N04P01P Output 1 1 — — — — 16 66.7 — — 8.5 35.4 S10N06P01P 1 1.5 30 125 31.5 131 — — 16.5 68.7 — — S10N04P16P 1 1.5 — — — — 24 100 — — 12.7 53.1 S10N06P16P 1 2 40 167 42 175 — — 22 91.7 — — S10N04P02P 1 2 — — — — 32 133 — — 17 70.8 S10N06P02P 1 3 60 249.9 63 262.5 — — 33 137.4 — — S10N04A03N 1 3 — — — — 48 200.1 — — 25.5 106.2 S10N06A03N 1 5 100 416.5 105 437.5 — — 55 229 — — S10N04A05N 1 5 — — — — 80 333 — — 42.5 177 S10N06A05N 1 7.5 150 624 157 656 — — 82.5 344 — — S10N04A07N 1 7.5 — — — — 120 500 — — 63.7 266 S10N06A07N Connection Diagram 2 E E E F F 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-153 2.5 2 2 Transformers Distribution Transformers Three-Phase Open Delta Connection 230 Volt Output Required, 60 Hz Input Available Voltage 199 203 207 209 216 Output Output Output Output Output Units Required 1 Unit kVA kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 2 0.05 — — — — 0.75 1.87 0.83 2.08 — — S10N04A81N 2 2 0.05 0.54 1.35 0.62 1.56 — — — — 1.24 3.12 S10N06A81N 2 2 0.10 — — — — 1.49 3.75 1.66 4.17 — — S10N04A82N 2 0.10 1.08 2.71 1.24 3.12 — — — — 2.49 6.25 S10N06A82N 2 2 0.15 — — — — 2.24 5.62 2.49 6.25 — — S10N04A83N 2 0.15 1.62 4.06 1.87 4.69 — — — — 3.73 9.37 S10N06A83N 2 2 0.25 — — — — 3.3 9.37 4.15 10.4 — — S10N04P26P 2 2 0.25 2.7 6.77 3.11 7.81 — — — — 6.22 15.6 S10N06P26P 2 0.50 — — — — 7.47 18.7 8.3 20.8 — — S10N04P51P 2 2 0.50 5.39 13.5 6.22 15.6 — — — — 12.4 31.2 S10N06P51P 2 0.75 — — — — 11.2 28.2 12.4 31.2 — — S10N04P76P 2 2 0.75 8.09 20.3 9.33 23.4 — — — — 18.7 46.8 S10N06P76P 2 1 — — — — 14.9 37.5 16.6 41.7 — — S10N04P01P 2 2 1 10.8 27.1 12.4 31.2 — — — — 24.9 62.5 S10N06P01P 2 2 1.5 — — — — 22.4 56.2 24.9 62.5 — — S10N04P16P 2 1.5 16.2 40.6 18.7 46.9 — — — — 37.3 93.7 S10N06P16P 2 2 2 — — — — 29.9 75 33.2 83.3 — — S10N04P02P 2 2 21.6 54.2 24.9 62.5 — — — — 49.8 125 S10N06P02P 2 2 3 — — — — 44.7 112.5 49.8 125.1 — — S10N04A03N 2 3 32.4 81.3 32.7 93.6 — — — — 74.7 187.5 S10N06A03N 2 2 5 — — — — 74.7 187 83 208 — — S10N04A05N 2 2 5 53.9 135 62.2 156 — — — — 124 312.5 S10N06A05N 2 7.5 — — — — 112 282 124 312 — — S10N04A07N 2 7.5 80.9 203 93.3 234 — — — — 187 468 S10N06A07N 2 2 2 2 2 2 Connection Diagram 2 L K L K Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-154 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com I Transformers Distribution Transformers 2.5 Three-Phase Open Delta Connection 230 Volt Output Required, 60 Hz 2 Input Available Voltage 2 219 242 246 253 Units Required 1 Unit kVA Output Output Output Output 260 kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 2 0.05 1.66 4.17 1.74 4.37 — — 0.91 2.29 — — S10N04A81N 2 0.05 — — — — 1.33 3.33 — — 0.70 1.77 S10N06A81N 2 0.10 3.32 8.33 3.48 8.75 — — 1.83 4.58 — — S10N04A82N 2 0.10 — — — — 2.65 6.67 — — 1.41 3.54 S10N06A82N 2 0.15 4.98 12.5 5.23 13.1 — — 2.74 6.87 — — S10N04A83N 2 0.15 — — — — 3.98 10.0 — — 2.12 5.13 S10N06A83N 2 0.25 8.3 20.8 8.71 21.9 — — 4.56 11.5 — — S10N04P26P 2 0.25 — — — — 6.64 16.7 — — 3.52 8.85 S10N06P26P Output 2 0.50 16.6 41.7 17.4 43.7 — — 9.73 22.9 — — S10N04P51P 2 0.50 — — — — 13.3 33.3 — — 7.05 17.7 S10N06P51P 2 0.75 24.9 62.4 26.1 65.6 — — 13.7 34.4 — — S10N04P76P 2 0.75 — — — — 19.9 50 — — 10.6 26.6 S10N06P76P 2 1 33.2 83.3 34.8 87.5 — — 18.3 45.8 — — S10N04P01P 2 1 — — — — 26.5 66.7 — — 14.1 35.4 S10N06P01P 2 1.5 49.8 125 52.3 131 — — 27.4 68.7 — — S10N04P16P 2 1.5 — — — — 39.8 100 — — 21.2 53.1 S10N06P16P 2 2 66.4 167 69.7 175 — — 36.5 91.7 — — S10N04P02P 2 2 — — — — 53.1 133 — — 28.2 70.8 S10N06P02P 2 3 99.6 249.9 104.4 262.5 — — 54.9 137.4 — — S10N04A03N 2 3 — — — — 79.5 200 — — 42.3 106.2 S10N06A03N 2 5 166 417 174 437 — — 91.3 229 — — S10N04A05N 2 5 — — — — 133 333 — — 70.5 177 S10N06A05N 2 7.5 249 624 261 656 — — 137 344 — — S10N04A07N 2 7.5 — — — — 199 500 — — 106 266 S10N06A07N Connection Diagram 2 I I I K K 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-155 2.5 2 2 Transformers Distribution Transformers Three-Phase Open Delta Connection 240 Volt Output Required, 60 Hz Input Available Voltage 208 212 216 218 Units Required 1 Unit kVA Output Output Output Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 2 0.05 — — — — 0.73 1.87 0.87 2.08 — — S10N04A81N 2 2 0.05 0.56 1.35 0.65 1.56 — — — — 1.3 3.12 S10N06A81N 2 2 0.10 — — — — 1.56 3.75 1.73 4.17 — — S10N04A82N 2 0.10 1.13 2.71 1.3 3.12 — — — — 2.6 6.25 S10N06A82N 2 2 0.15 — — — — 2.34 5.62 2.6 6.25 — — S10N04A83N 2 0.15 1.69 4.06 1.95 4.69 — — — — 3.9 9.37 S10N06A83N 2 2 0.25 —— — — — 3.9 9.37 4.33 10.4 — — S10N04P26P 2 2 0.25 2.81 6.77 3.25 7.81 — — — — 6.49 15.6 S10N06P26P 2 0.50 — — — — 7.79 18.7 8.66 20.8 — — S10N04P51P 2 2 0.50 5.63 13.5 6.5 15.6 —— — — — 13 31.2 S10N06P51P 2 0.75 — — — — 11.7 28.2 13 31.2 — — S10N04P76P 2 2 0.75 8.44 20.3 9.75 23.4 — — — — 19.5 46.8 S10N06P76P 2 1 — — — — 15.6 37.5 17.3 41.7 — — S10N04P01P 2 2 1 11.3 27.1 13 31.2 — — — — 26 62.5 S10N06P01P 2 2 1.5 — — — — 23.4 56.2 26 62.5 — — S10N04P16P 2 1.5 16.9 40.6 19.5 46.9 — — — — 39 93.7 S10N06P16P 2 2 2 — — — — 31.2 75 34.6 83.3 — — S10N04P02P 2 2 22.5 54.2 26 62.5 — — — — 52 125 S10N06P02P 2 2 3 — — — — 46.8 112.5 51.9 125.1 — — S10N04A03N 2 3 33.9 81.3 39 93.6 — — — — 78 187.5 S10N06A03N 2 2 5 — — — — 77.9 187 86.6 208 — — S10N04A05N 2 2 5 56.3 135 65 156 — — — — 130 312 S10N06A05N 2 7.5 — — — — 117 282 130 312 — — S10N04A07N 2 7.5 84.4 203 97.5 234 — — — — 195 468 S10N06A07N 2 2 2 2 2 2 Connection Diagram 2 L K L K Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-156 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 225 Output I Transformers Distribution Transformers 2.5 Three-Phase Open Delta Connection 240 Volt Output Required, 60 Hz 2 Input Available Voltage 2 229 252 256 264 Units Required 1 Unit kVA Output Output Output Output 272 kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 2 0.05 1.73 4.16 1.82 4.37 — — 0.95 2.29 — — S10N04A81N Output 2 0.05 — — — — 1.38 3.33 — — 0.74 1.77 S10N06A81N 2 0.10 3.46 8.33 3.64 8.75 — — 1.91 4.58 — — S10N04A82N 2 0.10 — — — — 2.77 6.67 — — 1.47 3.54 S10N06A82N 2 0.15 5.19 12.5 5.45 13.1 — — 2.86 6.87 — — S10N04A83N 2 0.15 — — — — 4.15 10.0 — — 2.21 5.31 S10N06A83N 2 0.25 8.66 20.8 9.09 21.9 — — 4.76 11.5 — — S10N04P26P 2 0.25 — — — — 6.92 16.7 — — 3.68 8.85 S10N06P26P 2 0.50 17.3 41.6 18.2 43.7 — — 9.53 22.9 — — S10N04P51P 2 0.50 — — — — 13.8 33.3 — — 7.36 17.7 S10N06P51P 2 0.75 26 62.4 27.3 65.6 — — 14.3 34.4 — — S10N04P76P 2 0.75 — — — — 20.8 50 — — 11 26.6 S10N06P76P 2 1 34.6 83.3 36.4 87.5 — — 19.1 45.8 — — S10N04P01P 2 1 — — — — 27.7 66.7 — — 14.7 35.4 S10N06P01P 2 1.5 51.9 125 54.5 131 — — 28.6 68.7 — — S10N04P16P 2 1.5 — — — — 41.5 100 — — 22.1 53.1 S10N06P16P 2 2 69.3 167 72.7 175 — — 38.1 91.7 — — S10N04P02P 2 2 — — — — 55.4 133 — — 29.4 70.8 S10N06P02P 2 3 103.8 249.9 109.2 262.5 — — 57.3 137.4 — — S10N04A03N 2 3 — — — — 83.1 200 — — 44.1 106.2 S10N06A03N 2 5 173 416 182 437 — — 95.3 229 — — S10N04A05N 2 5 — — — — 138 333 — — 73.6 177 S10N06A05N 2 7.5 260 624 273 656 — — 143 344 — — S10N04A07N 2 7.5 — — — — 208 500 — — 110 266 S10N06A07N Connection Diagram 2 I I I K K 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-157 2.5 2 2 2 2 2 2 2 Transformers Distribution Transformers WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output requires four-wire wye input. Three-Phase Wye Connection 208 Volt Output Required, 60 Hz Input Available Voltage 152 164 173 180 Units Required 1 Unit kVA Output Output Output Output 184 kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 3 0.05 — — — — 0.75 2.08 — — — — S10N04A81N Output 3 0.05 0.41 1.15 0.56 1.56 — — 0.98 2.71 1.12 3.12 S10N06A81N 3 0.10 — — — — 1.50 4.17 — — — — S10N04A82N 3 0.10 0.82 2.29 1.12 3.12 — — 1.95 5.41 2.25 6.25 S10N06A82N 2 3 0.15 — — — — 2.25 6.25 — — — — S10N04A83N 3 0.15 1.24 3.44 1.69 4.69 — — 2.92 8.12 3.73 9.37 S10N06A83N 2 3 0.25 — — — — 3.75 10.4 — — — — S10N04P26P S10N06P26P 3 0.25 2.06 5.73 2.81 7.81 — — 4.87 13.5 5.62 15.6 2 3 0.50 — — — — 7.5 20.8 — — — — S10N04P51P 2 3 0.50 4.12 11.5 5.62 15.6 — — 9.75 27.1 11.2 31.2 S10N06P51P 3 0.75 — — — — 11.2 31.2 — — — — S10N04P76P 2 3 0.75 6.19 17.2 8.44 23.4 — — 14.6 40.6 16.8 46.8 S10N06P76P 3 1 — — — — 15 41.7 — — — — S10N04P01P 2 3 1 8.25 22.9 11.2 31.2 — — 19.5 54.1 22.5 62.5 S10N06P01P 3 1.5 — — — — 22.5 62.5 — — — — S10N04P16P 3 1.5 12.4 34.4 16.9 46.9 — — 29.2 81.2 33.7 93.7 S10N06P16P 3 2 — — — — 30 83.3 — — — — S10N04P02P 3 2 16.5 45.8 22.5 62.5 — — 39 108 45 125 S10N06P02P 2 2 2 3 3 — — — — 45 125 — — — — S10N04A03N 3 3 24.7 68.7 33.6 93.6 — — 58.5 162.3 67.5 187.5 S10N06A03N 2 3 5 — — — — 75 208 — — — — S10N04A05N 2 3 5 41.2 115 56.2 156 — — 97.5 271 112 312 S10N06A05N 3 7.5 — — — — 112 312 — — — — S10N04A07N 3 7.5 61.9 172 84.4 234 — — 146 406 168 468 S10N06A07N 2 2 2 2 2 Connection Diagram 2 P N N O Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 V2-T2-158 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com M Transformers Distribution Transformers 2.5 WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output requires four-wire wye input. 2 Three-Phase Wye Connection 208 Volt Output Required, 60 Hz 2 Input Available Voltage 189 229 236 Output 250 Output 264 Output 2 Units Required 1 Unit kVA Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 3 0.05 1.5 4.16 1.65 4.58 — — 0.9 2.5 — — S10N04A81N 3 0.05 — — — — 1.27 3.54 — — 0.71 1.98 S10N06A81N 3 0.10 3.0 8.33 3.3 9.17 — — 1.8 5.0 — — S10N04A82N Output 3 0.10 — — — — 2.55 7.08 — — 1.42 3.95 S10N06A82N 3 0.15 4.5 12.5 4.95 13.7 — — 2.7 7.5 — — S10N04A83N 3 0.15 — — — — 3.82 10.6 — — 2.14 5.93 S10N06A83N 3 0.25 7.5 20.8 8.25 22.9 — — 4.5 12.5 — — S10N04P26P 3 0.25 — — — — 6.35 17.7 — — 3.56 9.88 S10N06P26P 9 25 — — S10N04P51P — 7.12 19.3 S10N06P51P 3 0.50 15 41.6 16.5 45.8 — — 3 0.50 — — — — 12.7 35.4 3 0.75 22.5 62.4 24.7 68.7 — — 13.5 37.5 — — S10N04P76P 3 0.75 — — — — 19 53.1 — — 10.7 29.3 S10N06P76P 3 1 30 83.3 33 91.7 — — 18 50 — — S10N04P01P 3 1 — — — — 25.5 70.8 — — 14.2 39.5 S10N06P01P 3 1.5 45 125 49.5 137 — — 27 75 — — S10N04P16P 3 1.5 — — — — 38.2 106 — — 21.4 59.3 S10N06P16P 3 2 60 167 66 183 — — 361 100 — — S10N04P02P 3 2 — — — — 51 142 — — 28.5 79.2 S10N06P02P 3 3 90 249.9 99 275.1 — — 54 150 — — S10N04A03N 3 3 — — — — 76.5 212.4 — — 46.2 118.5 S10N06A03N 3 5 150 416 165 458 — — 90 250 — — S10N04A05N 3 5 — — — — 127 354 — — 71.2 198 S10N06A05N 3 7.5 225 624 274 687 — — 135 375 — — S10N04A07N 3 7.5 — — — — 190 531 — — 107 293 S10N06A07N Connection Diagram 2 M M 2 M N N 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-159 2.5 2 2 2 2 2 Transformers Distribution Transformers WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output requires four-wire wye input. Three-Phase Wye Connection 230 Volt Output Required, 60 Hz Input Available Voltage 183 192 199 208 218 Output Output Output Output Output Units Required 1 Unit kVA kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 3 0.05 — — 0.83 2.08 — — 1.65 4.58 1.66 4.17 S10N04A81N 2 3 0.05 0.62 1.56 — — 0.54 1.35 — — — — S10N06A81N 2 3 0.10 — — 1.66 4.17 — — 3.3 9.17 3.32 8.35 S10N04A82N 3 0.10 1.25 3.12 — — 1.08 2.71 — — — — S10N06A82N 2 3 0.15 — — 2.49 6.25 — — 4.95 13.7 4.98 12.5 S10N04A83N 3 0.15 1.87 4.69 — — 1.62 4.06 — — — — S10N06A83N 2 3 0.25 — — 4.15 10.4 — — 8.2 22.9 8.3 20.9 S10N04P26P 3 0.25 3.11 7.81 — — 2.70 6.77 — — — — S10N06P26P 2 3 0.50 — — 8.3 20.8 — — 16.5 45.8 16.6 41.7 S10N04P51P 2 3 0.50 6.22 15.6 — — 5.39 13.5 — — — — S10N06P51P 3 0.75 — — 12.4 31.2 — — 24.7 68.8 24.9 62.6 S10N04P76P 2 3 0.75 9.33 23.4 — — 8.09 20.3 — — — — S10N06P76P 3 1 — — 16.6 41.7 — — 33 91.7 33.2 83.5 S10N04P01P 2 3 1 12.5 31.2 — — 10.8 27.1 — — — — S10N06P01P 3 1.5 — — 24.9 62.5 — — 49.5 137 49.8 125 S10N04P16P 2 3 1.5 18.7 46.9 — — 16.2 40.6 — — — — S10N06P16P 2 3 2 — — 33.2 83.3 — — 66 183 66.4 167 S10N04P02P 3 2 24.9 62.5 — — 21.6 54.2 — — — — S10N06P02P 2 3 3 — — 49.8 125.1 — — 99 275 99.6 250.5 S10N04A03N 3 3 37.5 93.6 — — 32.4 81.3 — — — — S10N06A03N 2 3 5 — — 83 208 — — 165 458 166 417 S10N04A05N 2 3 5 62.2 156 — — 53.9 135 — — — — S10N06A05N 3 7.5 — — 124 312 — — 247 688 249 626 S10N04A07N 2 3 7.5 93.3 234 — — 80.9 203 — — — — S10N06A07N 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 2 2 Connection Diagram 2 N N S M Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 V2-T2-160 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Q Transformers Distribution Transformers 2.5 WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output requires four-wire wye input. 2 Three-Phase Wye Connection 230 Volt Output Required, 60 Hz 2 Input Available Voltage 242 245 253 Output 260 Output 265 Output 2 Units Required 1 Unit kVA Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 3 0.05 1.74 4.37 — — 0.91 2.29 — — — — S10N04A81N 3 0.05 — — 1.33 3.33 — — 0.70 1.77 0.62 1.56 S10N06A81N 3 0.10 3.48 8.75 — — 1.83 4.58 — — — — S10N04A82N Output 3 0.10 — — 2.65 6.67 — — 1.41 3.54 1.25 3.12 S10N06A82N 3 0.15 5.23 13.1 — — 2.74 6.87 — — — — S10N04A83N 3 0.15 — — 3.98 10.0 — — 2.12 5.31 1.87 4.69 S10N06A83N 3 0.25 8.71 21.9 — — 4.56 11.5 — — — — S10N04P26P 3 0.25 — — 6.63 16.7 — — 3.52 8.85 3.11 7.81 S10N06P26P 3 0.50 17.4 43.7 — — 9.31 22.9 — — — — S10N04P51P 3 0.50 — — 13.3 33.3 — — 7.05 17.7 6.22 15.6 S10N06P51P 3 0.75 26.1 65.6 — — 13.7 34.4 — — — — S10N04P76P 3 0.75 — — 19.9 50 — — 10.6 26.6 9.33 23.4 S10N06P76P 3 1 34.8 87.5 — — 18.3 45.8 — — — — S10N04P01P 3 1 — — 26.5 66.7 — — 14.1 35.4 12.5 31.2 S10N06P01P 3 1.5 52.3 131 — — 27.4 68.7 — — — — S10N04P16P 3 1.5 — — 39.8 100 — — 21.2 53.1 18.7 46.9 S10N06P16P 3 2 69.7 175 — — 36.6 91.6 — — — — S10N04P02P 3 2 — — 53.1 133 — — 28.2 70.8 24.9 62.5 S10N06P02P 3 3 104.4 262.5 — — 54.9 137.4 — — — — S10N04A03N 3 3 — — 79.5 200 — — 42.3 106.2 37.5 93.6 S10N06A03N 3 5 174 437 — — 91.3 229 — — — — S10N04A05N 3 5 — — 133 333 — — 70.5 177 62.2 156 S10N06A05N — — — S10N04A07N 266 93.3 234 S10N06A07N 3 7.5 261 656 — — 137 344 3 7.5 — — 199 500 — — Connection Diagram 2 Q Q 2 R 106 R S 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-161 2.5 2 2 2 Transformers Distribution Transformers WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output requires four-wire wye input. Three-Phase Wye Connection 240 Volt Output Required, 60 Hz Input Available Voltage 190 200 208 218 Units Required 1 Unit kVA Output Output Output Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 3 0.05 — — 0.86 2.08 — — 0.86 2.08 1.73 4.17 S10N04A81N 2 3 0.05 0.65 1.65 — — 1.27 3.05 — — — — S10N06A81N 2 3 0.10 — — 1.73 4.17 — — 1.73 4.17 3.46 8.34 S10N04A82N 3 0.10 1.3 3.12 — — 2.55 6.12 — — — — S10N06A82N 2 3 0.15 — — 2.59 6.25 — — 2.59 6.25 5.20 12.5 S10N04A83N 3 0.15 1.95 4.69 — — 3.82 9.16 — — — — S10N06A83N 2 3 0.25 — — 4.32 10.4 — — 4.32 10.4 8.66 20.9 S10N04P26P 3 0.25 3.25 7.81 — — 6.3 15.1 — — — — S10N06P26P 2 3 0.50 — — 8.65 20.8 — — 8.65 20.8 17.3 41.7 S10N04P51P 2 3 0.50 6.5 15.6 — — 12.7 30.4 — — — — S10N06P51P 3 0.75 — — 13 31.2 — — 13 31.2 26 62.6 S10N04P76P 2 3 0.75 9.75 23.4 — — 19.2 46 — — — — S10N06P76P 3 1 — — 17.3 41.7 — — 17.3 41.7 34.6 83.4 S10N04P01P 2 3 1 13 31.2 — — 25.5 61.2 — — — — S10N06P01P 3 1.5 — — 25.9 62.5 — — 25.9 62.5 52 125 S10N04P16P 2 3 1.5 19.5 46.9 — — 38.2 91.6 — — — — S10N06P16P 2 3 2 — — 34.6 83.3 — — 34.6 83.3 69.3 167 S10N04P02P 3 2 26 62.5 — — 51 122.4 — — — — S10N06P02P 2 3 3 — — 51.9 125.1 — — 51.9 125.1 103.8 250.2 S10N04A03N 3 3 39 93.6 — — 76.5 183.6 — — — — S10N06A03N 2 3 5 — — 86.5 208 — — 86.5 208 173 417 S10N04A05N 2 3 5 65 156 — — 127.2 305.2 — — — — S10N06A05N 3 7.5 — — 130 312 — — 130 312 260 626 S10N04A07N 3 7.5 97.5 234 — — 192 460 — — — — S10N06A07N 2 2 2 2 2 2 2 Connection Diagram 2 N N M R Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 V2-T2-162 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 228 Output Q Transformers Distribution Transformers 2.5 WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output requires four-wire wye input. 2 Three-Phase Wye Connection 240 Volt Output Required, 60 Hz 2 Input Available Voltage 252 256 264 Output 272 Output 277 Output 2 Units Required 1 Unit kVA Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 3 0.05 1.85 4.37 — — 0.95 2.29 — — — — S10N04A81N 3 0.05 — — 1.39 3.33 — — 0.74 1.77 0.65 1.56 S10N06A81N 3 0.10 3.64 8.75 — — 1.91 4.58 — — — — S10N04A82N Output 3 0.10 — — 2.77 6.67 — — 1.47 3.54 1.3 3.12 S10N06A82N 3 0.15 5.46 13.1 — — 2.86 6.87 — — — — S10N04A83N 3 0.15 — — 4.16 10.0 — — 2.21 5.31 1.95 4.69 S10N06A83N 3 0.25 9.09 21.9 — — 4.76 11.5 — — — — S10N04P26P 3 0.25 — — 6.93 16.7 — — 3.68 8.85 3.25 7.81 S10N06P26P 3 0.50 18.2 43.7 — — 9.53 22.9 — — — — S10N04P51P 3 0.50 — — 13.9 33.3 — — 7.36 17.7 6.5 15.6 S10N06P51P 3 0.75 27.3 65.6 — — 14.3 34.4 — — — — S10N04P76P 3 0.75 — — 20.8 50 — — 11 26.6 9.75 23.4 S10N06P76P 3 1 36.4 87.5 — — 19.1 45.8 — — — — S10N04P01P 3 1 — — 27.7 66.7 — — 14.7 35.4 13 31.2 S10N06P01P 3 1.5 54.6 131 — — 28.6 68.7 — — — — S10N04P16P 3 1.5 — — 41.6 100 — — 22.1 53.1 19.5 46.9 S10N06P16P 3 2 72.8 175 — — 38.1 91.7 — — — — S10N04P02P 3 2 — — 55.4 133 — — 29.5 70.8 26 62.5 S10N06P02P 3 3 109.2 262.5 — — 57.3 137.4 — — — — S10N04A03N 3 3 — — 83.1 200 — — 44.1 106.2 39 93.6 S10N06A03N 3 5 182 437 — — 95.3 229 — — — — S10N04A05N 3 5 — — 139 333 — — 73.6 177 65 156 S10N06A05N 3 7.5 273 656 — — 143 344 — — — — S10N04A07N 3 7.5 — — 208 500 — — 110 266 97.5 234 S10N06A07N Connection Diagram 2 Q Q 2 R R S 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-163 2.5 2 2 2 2 2 Transformers Distribution Transformers WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output requires four-wire wye input. Three-Phase Wye Connection 460 Volt Output Required, 60 Hz Input Available Voltage 406 418 432 Output Output Output 438 Output Units Required 1 Unit kVA kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 3 0.05 — — 1.66 2.08 — — 3.22 4.04 S10N04A81N 2 3 0.05 1.25 1.57 — — 2.49 3.12 — — S10N06A81N 2 3 0.10 — — 3.31 4.15 — — 6.62 8.31 S10N04A82N 3 0.10 2.49 3.12 — — 4.97 6.24 — — S10N06A82N 3 0.15 — — 4.97 6.24 — — 9.94 12.48 S10N04A83N 3 0.15 3.73 4.68 — — 7.46 9.36 — — S10N06A83N 3 0.25 — — 8.28 10.39 — — 16.6 20.84 S10N04P26P 3 0.25 6.22 7.81 — — 12.4 15.56 — — S10N06P26P 2 3 0.50 — — 16.6 20.84 — — 33.2 41.67 S10N04P51P 2 3 0.50 12.5 15.69 — — 24.69 31.25 — — S10N06P51P 3 0.75 — — 24.8 31.12 — — 49.6 62.25 S10N04P76P 2 3 0.75 18.7 23.47 — — 37.3 46.82 — — S10N06P76P 3 1 — — 33.1 41.54 — — 66.2 83.09 S10N04P01P 2 3 1 24.9 31.25 — — 49.7 62.38 — — S10N06P01P 3 1.5 — — 49.7 62.38 — — 99.4 124.75 S10N04P16P 2 3 1.5 37.3 46.94 — — 74.6 93.63 — — S10N06P16P 2 3 2 — — 66.3 83.22 — — 133 166.93 S10N04P02P 3 2 49.7 62.38 — — 99.5 124.88 — — S10N06P02P 2 3 3 — — 99.3 124.64 — — 198.6 249.27 S10N04A03N 3 3 74.6 93.63 — — 149 187.01 — — S10N06A03N 2 3 5 — — 166 208.35 — — 322 404.16 S10N04A05N 2 3 5 125 156.89 — — 249 312.53 — — S10N06A05N 3 7.5 — — 248 311 — — 496 622 S10N04A07N 3 7.5 187 235 — — 373 468 — — S10N06A07N 2 2 2 2 2 2 2 Connection Diagram 2 R R Q Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 V2-T2-164 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Q Transformers Distribution Transformers 2.5 WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output requires four-wire wye input. 2 Three-Phase Wye Connection 460 Volt Output Required, 60 Hz 2 Input Available Voltage 424 436 450 Output 2 Units Required 1 Unit kVA Output kVA Amps kVA Amps kVA Amps Catalog Number 3 0.05 — 1.7 2.1 — — — S10N04A81N 3 0.05 1.3 1.56 — — 2.6 3.13 S10N06A81N 3 0.10 — — 3.5 4.2 — — S10N04A82N 3 0.10 2.6 3 0.15 Output 3 0.15 3 3 3.12 — — 5.2 6.25 S10N06A82N — 5.2 6.25 — — S10N04A83N 3.9 4.68 — — 7.8 9.38 S10N06A83N 0.25 — — 8.7 10.4 — — S10N04P26P 0.25 6.5 7.82 — — 13 15.6 S10N06P26P 3 0.50 — — 17.4 20.9 — — S10N04P51P 3 0.50 13 15.6 — — 26 31.2 S10N06P51P 3 0.75 — — 26 31.2 — — S10N04P76P 3 0.75 19.5 23.4 — — 39 46.9 S10N06P76P 3 1 — — 35 42 — — S10N04P01P 3 1 26 31.2 — — 52 62.5 S10N06P01P 3 1.5 — — 52 62.5 — — S10N04P16P 3 1.5 39 46.8 — — 78 93.8 S10N06P16P 3 2 — — 69 82.9 — — S10N04P02P 3 2 52 62.5 — — 104 125 S10N06P02P 3 3 — — 104 125 — — S10N04A03N 3 3 78 93.8 — — 156 187.6 S10N06A03N 3 5 — — 174 209.2 — — S10N04A05N 3 5 130 156.3 — — 260 312.7 S10N06A05N 3 7.5 — — 260 312 — — S10N04A07N 3 7.5 195 234 — — 390 469 S10N06A07N Connection Diagram 2 R 2 R Q 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-165 2.5 2 2 Transformers Distribution Transformers Single-Phase Required, 60 Hz Input Available Voltage/Output Voltage 200/240 230/277 346/380 Output Output Output 362/380 Output Units Required 1 Unit kVA kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 1 0.25 1.25 5.2 1.44 5.2 1.98 5.2 3.95 10.4 S20N08P26P 2 1 0.50 2.50 10.4 2.88 10.4 3.95 10.4 7.90 20.8 S20N08P51P 2 1 0.75 3.75 15.6 4.32 15.6 5.93 15.6 11.9 31.2 S20N08P76P 1 1 5.00 20.8 5.76 20.8 7.90 20.8 15.8 41.6 S20N08P01P 2 1 1.5 7.50 31.2 8.64 31.2 11.9 31.2 23.8 62.5 S20N08P16P 1 2 10.0 41.6 11.5 41.6 15.8 41.6 31.6 83.3 S20N08P02P 2 1 3 15.0 62.5 17.3 62.5 23.8 62.5 47.5 125.0 S20N08A03N 2 1 5 25.0 104.0 28.8 104.0 39.5 104.0 79.0 208.0 S20N08A05N 1 7.5 37.5 156.0 43.2 156.0 59.3 156.0 118.6 312.0 S20N08A07N Amps Catalog Number 2 2 2 Connection Diagram 2 B B F E 458/480 Single-Phase Required, 60 Hz Input Available Voltage/Output Voltage 2 378/416 416/457 436/480 Output Output Output Output 2 Units Required 1 2 1 0.25 2.16 5.2 2.38 5.2 2.50 5.2 4.99 10.4 S20N08P26P 1 0.50 4.33 10.4 4.76 10.4 4.99 10.4 9.98 20.8 S20N08P51P 2 1 0.75 6.49 15.6 7.14 15.6 7.49 15.6 15.0 31.2 S20N08P76P 2 1 1 8.65 20.8 9.52 20.8 9.98 20.8 20.0 41.6 S20N08P01P 1 1.5 13.0 31.2 14.3 31.2 15.0 31.2 30.0 62.5 S20N08P16P 2 1 2 17.3 41.6 19.0 41.6 20.0 41.6 40.0 83.3 S20N08P02P 1 3 26.0 62.5 28.6 62.5 30.0 62.5 60.0 125.0 S20N08A03N 2 1 5 43.3 104.0 47.6 104.0 49.9 104.0 99.8 208.0 S20N08A05N 1 7.5 64.9 156.0 71.4 156.0 74.9 156.0 149.8 312.0 S20N08A07N 2 Connection Diagram 2 Unit kVA kVA Amps F kVA F Amps kVA Amps F 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 V2-T2-166 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com kVA E Transformers Distribution Transformers 2.5 Single-Phase Required, 60 Hz 2 Input Available Voltage/Output Voltage 277/230 480/456 504/480 Output Output Output 2 528/480 Output Units Required 1 Unit kVA kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 1 0.25 1.44 6.26 5.23 11.4 5.47 11.4 2.75 5.72 S20N08P26P 1 0.50 2.88 12.5 10.4 22.8 10.9 22.8 5.49 11.4 S20N08P51P 1 0.75 4.33 18.8 15.7 34.2 16.4 34.2 8.24 17.2 S20N08P76P 1 1 5.76 25.0 20.9 45.6 21.8 45.6 11.0 22.9 S20N08P01P 1 1.5 8.64 37.6 31.3 68.4 32.8 68.4 16.5 34.3 S20N08P16P 1 2 11.5 50.1 41.8 91.2 43.7 91.2 22.0 45.8 S20N08P02P 1 3 17.3 75.3 62.7 136.0 65.2 136.0 33.0 68.8 S20N08A03N 1 5 28.8 125.3 104.5 227.0 108.0 227.0 54.9 114.4 S20N08A05N 1 7.5 43.2 187.9 156.8 341.0 163.0 341.0 82.4 171.6 S20N08A07N Connection Diagram 2 B E E F 2 2 2 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-167 2.5 2 2 Transformers Distribution Transformers Three-Phase Required, 60 Hz Input Available Voltage/Output Voltage 362/380 346/416 430/473 400/480 Unit kVA Output Output Output Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps Catalog Number 0.25 6.52 10.4 3.75 5.2 4.26 5.2 4.33 5.2 4.33 5.2 S20N08P26P 2 0.50 13.0 20.8 7.50 10.4 8.52 10.4 8.65 10.4 8.65 10.4 S20N08P51P 2 0.75 19.6 31.2 11.2 15.6 12.8 15.6 13.0 15.6 13.0 15.6 S20N08P76P 1 26.1 41.6 15.0 20.8 17.0 20.8 17.3 20.8 17.3 20.8 S20N08P01P 2 1.5 39.1 62.4 22.5 31.2 25.5 31.2 26.0 31.2 26.0 31.2 S20N08P16P 2 52.2 83.2 30.0 41.6 34.1 41.6 34.6 41.6 34.6 41.6 S20N08P02P 2 3 78.4 125.0 45.0 62.5 51.2 62.5 52.0 62.5 52.0 62.5 S20N08A03N 2 5 130.4 208.0 75.1 104.0 85.2 104.0 86.6 104.0 86.6 104.0 S20N08A05N 7.5 195.6 312.0 112.6 156.0 127.8 156.0 129.9 156.0 129.9 156.0 S20N08A07N Connection Diagram 1 I N K N K Units Required 2 2 3 2 3 2 2 2 436/480 Output 2 2 2 Three-Phase Required, 60 Hz Input Available Voltage/Output Voltage 460/483 457/380 504/480 528/480 Unit kVA Output Output Output Output 0.25 8.7 10.4 4.12 6.25 9.08 10.9 2 0.50 17.4 20.8 8.23 12.5 18.2 21.8 2 0.75 26.1 31.2 12.3 18.8 27.2 32.8 1 34.8 41.6 16.5 25.0 36.3 2 1.5 52.2 62.4 24.7 37.5 2 69.6 83.2 32.9 2 3 104.6 125.0 5 174.0 2 7.5 261.0 2 Connection Diagram 1 I N I K Units Required 2 2 3 2 2 2 2 2 2 2 kVA Amps Catalog Number 4.76 5.72 S20N08P26P 9.51 11.4 S20N08P51P 14.3 17.2 S20N08P76P 43.7 19.0 22.9 S20N08P01P 54.5 65.5 28.5 34.3 S20N08P16P 50.0 72.6 87.4 38.0 45.8 S20N08P02P 49.5 75.2 109.7 131.3 57.2 68.8 S20N08A03N 208.0 82.3 125.1 181.6 218.4 95.1 114.4 S20N08A05N 312.0 123.5 187.6 272.4 327.6 142.7 171.6 S20N08A07N Amps kVA Amps kVA Amps Notes 1 Refer to Page V2-T2-172 for buck-boost wiring diagrams. 2 Additional wiring trough may be required. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 V2-T2-168 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com kVA 2.5 Transformers Distribution Transformers Three-Phase Open Delta Connection 480 Volt Output Required, 60 Hz 2 Input Available Voltage 600 575 575 Output Output Output 2 Units Required 1 kVA Amps kVA Amps kVA Amps Catalog Number 2 2 4.3 5.1 — — — — S20N11P51P 2 — — — — 4.1 4.9 S60G11P51P 2 6.5 7.8 — — — — S20N11P76P 2 — — — — 6.2 7.4 S60G11P76P 2 8.6 10.3 — — — — S20N11P01P 2 — — — — 8.3 9.9 S60G11P01P 2 13.0 15.6 — — — — S20N11P16P 2 — — — — 12.4 14.9 S60G11P16P 2 17.2 20.6 — — — — S20N11P02P 2 — — — — 16.5 19.8 S60G11P02P 2 25.8 31 — — — — S20N11S03N 2 — — — — 24.8 29.8 S60G11P03P 2 43.2 51.9 — — — — S20N11S05N 2 — — — — 41 49.3 S60G11S05N 2 65 78.1 — — — — S20N11S07N 2 — — — — 62 74.5 S60G11S07N 2 86 103.4 — — — — S20N11S10N 2 — — 83 99.8 — — S60G11S10N 2 130 156.3 — — — — S20N11S15N 2 — — 124 149.1 — — S60N11S15N 2 2 2 2 2 2 2 2 2 2 2 2 216 259.8 — — — — T20P11S25EE 2 — — 207 248.9 — — S60J11S25N 2 324 389.7 — — — — T20P11S37EE 2 432 519.6 — — — — T20P11S50EE Connection Diagram 3 I J 2 T 2 2 2 2 Notes 1 Additional wiring trough may be required. 2 On transformers supplied with standard taps, taps must be placed at nominal settings. 3 Refer to Page V2-T2-172 for buck-boost wiring diagrams. 2 2 Autotransformers can be used only where local electric codes permit and isolation of the two circuits is not required. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage 2 Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage 2 Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-169 2.5 2 Distribution Transformers Single-Phase 480 Volt Output Required, 60 Hz Input Available Voltage 2 2 Transformers 600 575 Output Output 575 Output Units Required 1 kVA Amps kVA Amps kVA Amps Catalog Number 2 1 2.5 5.2 — — — — S20N11P51P 2 1 — — — — 2.4 5 S60G11P51P 2 1 3.7 7.7 — — — — S20N11P76P 1 — — — — 3.6 7.5 S60G11P76P 2 1 5.0 10.4 — — — — S20N11P01P 1 — — — — 4.8 10 S60G11P01P 2 1 7.5 15.6 — — — — S20N11P16P 2 1 — — — — 7.2 15 S60G11P16P 1 10 20.8 — — — — S20N11P02P 2 1 — — — — 9.6 20 S60G11P02P 1 15 31.2 — — — — S20N11S03N 2 1 — — — — 14.3 29.7 S60G11P03P 1 25 52 — — — — S20N11S05N 2 1 — — — — 24 50 S60G11S05N 2 1 37.5 78.1 — — — — S20N11S07N 1 — — — — 36 75 S60G11S07N 2 1 50 104.1 — — — — S20N11S10N 1 — — 43 100 — — S60G11S10N 2 1 75 156.2 — — — — S20N11S15N 1 — — 72 150 — — S60N11S15N 1 125 260.4 — — — — T20P11S25EE 1 — — 120 250 — — S60J11S25N 1 187 389.6 — — — — T20P11S37EE 1 250 520.8 — — — — T20P11S50EE Connection Diagram 3 E 2 2 2 2 2 2 2 2 2 H Notes 1 Additional wiring trough may be required. 2 On transformers supplied with standard taps, taps must be placed at nominal settings. 3 Refer to Page V2-T2-172 for buck-boost wiring diagrams. Autotransformers can be used only where local electric codes permit and isolation of the two circuits is not required. Rated Output Voltage Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating. Rated Input Voltage Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 V2-T2-170 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com U 2.5 Transformers Distribution Transformers Accessories Please refer to Section 2.7 Page V2-T2-191. 2 Technical Data and Specifications 2 Frequency Eaton buck-boost transformers are designed for 60 Hz operation. Enclosures Eaton encapsulated buckboost transformers use a NEMA 3R rated enclosure. Overload Capability Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour, and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Lugs are not supplied with these transformers. Eaton recommends that external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 55°C 10°C 105°C 40°C 80°C 30°C 150°C 25°C 135°C 20°C 180°C 40°C 115°C 30°C 185°C 40°C 150°C 30°C 220°C The design life of transformers having different insulation systems is the same—the lower-temperature systems are designed for the same life as the higher-temperature systems. Series-Multiple Windings Series-multiple windings consist of two similar coils in each winding that can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with an “x” or “/” between the voltage ratings, such as voltages of “120/240” or “240 x 480.” If the series-multiple winding is designated by an “x,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 x 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), 240 (series) or 240 with a 120 mid-point. Sound Levels All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Note: When installation is to be made on a grounded system, consideration must be given to the resulting voltage. Thus, on a 208 grounded wye/120 system, the voltage can be boosted to 240 volts but the voltage to ground will be 139 volts. If 240/120 volts with a mid-point ground is needed, a standard two-winding transformer must be used. The following formulas can be used to calculate specific requirements. For single-phase: Load Voltage x Line AmperesLOAD kVA = Full -------------------------------------------1000 2 2 2 2 2 2 2 2 2 For three-phase: For additional information, please refer to Section 2.7 Page V2-T2-195. 2 Line Load Voltage x 1.73 x Full Load Amperes LOAD kVA = ----------------------------------------------------------------1000 2 2 2 Average Sound Levels 2 NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 Encapsulated (up to 1.2 kV) 2 2 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 2 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 50.01 to 75.00 50 53 55 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 500.01 to 700.00 62 65 61 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-171 2.5 Transformers Distribution Transformers 2 Wiring Diagrams 2 Buck-Boost Transformers Wiring Diagrams Diagram A Diagram B 2 2 2 2 X4 X1 X2 H4 H3 H4 H3 H4 H3 H2 H1 H2 H1 H2 H1 X1 H3 H2 H1 X4 H2 X3 X4 X1 X2 X4 X4 X3 X2 X2 X1 H1 H1 H2 X4 X3 X2 X1 H4 H3 H2 H1 H1 H2 H3 H4 X3 X3 X2 X1 H4 X2 H3 H4 H3 H2 H1 H2 H1 H2 H1 H2 H1 Low Voltage X1 X4 X2 H3 Neutral Diagram P 1 X4 X2 X3 H4 H3 H4 H3 H4 H3 H2 H1 H2 H1 H2 H1 X1 X3 X3 X4 H4 H3 H4 H3 X1 H4 X2 H3 X1 H4 X2 H3 X1 H4 X2 H3 H2 H1 H2 H1 H2 H1 H2 H1 H2 X4 X3 H3 X2 X1 H1 H2 High Voltage X3 X4 X3 X4 X1 X2 X1 X2 X1 X2 H3 H4 H1 H2 H3 H4 H1 H2 H3 H1 H4 H2 Low Voltage H3 H4 X1 X3 X2 X1 H1 H2 High Voltage X4 X3 H3 H4 X1 X3 X1 X3 X2 X4 X2 X4 X2 H3 H1 H3 H1 H3 H1 H4 H2 H4 H2 X4 H4 H2 Low Voltage Neutral Neutral Diagram U High Voltage High Voltage X4 X3 H1 Neutral Diagram R 1 X4 Low Voltage X2 High Voltage Neutral Diagram T Diagram S 1 2 X4 X4 X3 Neutral High Voltage H4 X3 X3 X2 X4 X1 2 X1 X4 X4 High Voltage X3 X1 X3 X2 X3 Diagram Q 1 X1 2 H1 H2 H3 H4 Low Voltage Low Voltage Low Voltage 2 H4 H3 H2 H1 High Voltage X4 X1 H4 X2 X4 X3 X2 X1 Diagram O 1 X2 H3 X4 X1 X2 X3 X4 High Voltage X4 H1 H2 H3 H4 Low Voltage X1 X2 X3 X4 X1 H4 X2 X1 Diagram L X1 2 X3 X2 Low Voltage Diagram N 1 X3 X4 X2 H4 H3 H2 H1 H1 High Voltage X4 X4 X1 Low Voltage Diagram M 1 H1 X3 High Voltage X3 H2 High Voltage Low Voltage X1 X3 H3 Low Voltage H2 H1 Low Voltage 2 H4 Diagram K H2 2 H1 X4 Diagram I High Voltage 2 H2 X2 X3 High Voltage Diagram J 2 2 H3 X1 Low Voltage X3 H3 2 2 X2 Diagram H 2 2 X1 High Voltage 2 High Voltage X4 Low Voltage 2 High Voltage X3 H4 Diagram G H4 X2 Diagram F X4 H4 X2 X4 X1 High Voltage X2 X3 X1 X3 Low Voltage High Voltage 2 X4 Diagram E Low Voltage 2 2 X2 X3 Low Voltage 2 2 X1 Diagram D 2 Low Voltage High Voltage X3 2 2 Diagram C High Voltage X3 X4 X4 X3 X1 X2 X2 X1 X3 X4 X1 X2 H1 H2 Neutral H4 H1 H1 H4 Low Voltage H1 H4 Low Voltage Note 1 WARNING! If input is three-wire, “neutral” connection must be isolated and insulated! When used to supply a three-phase, four-wire load, the source must be three-phase, four-wire wye. V2-T2-172 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.5 Transformers Distribution Transformers Contents Description Page Motor Drive Isolation Transformers . . . . . . . . . . . . Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers. . . . Class I, Division 2, Hazardous Location Transformers Open-Type Core and Coil Assembly Transformers Marine Duty Transformers. . . . . . . . . . . . . . . . . . . Buck-Boost and Low Voltage Lighting Transformers Medium Voltage Distribution Transformers Features, Benefits and Functions . . . . . . . . . . . Standards and Certifications. . . . . . . . . . . . . . . Product Description . . . . . . . . . . . . . . . . . . . . . V2-T2-111 V2-T2-119 V2-T2-124 V2-T2-127 V2-T2-130 V2-T2-133 V2-T2-144 V2-T2-174 V2-T2-174 V2-T2-175 2 2 2 2 2 2 2 2 2 2 2 Medium Voltage Distribution Transformers Product Description Note: The following pages provide listings for most standard transformer ratings and catalog numbers. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Single- and Three-Phase ● Ventilated, NEMA 3R enclosure standard ● Suitable for indoor or outdoor applications ● Upright mounting only ● 220ºC insulation system ● 150ºC rise standard; 115°C or 80°C rise optional ● Available in single-phase ratings 15–333 kVA ● Available in single-phase ratings 25–167 kVA; in three-phase ratings 15–1500 kVA Application Description U.S. DOE 10 CFR Part 431 compliant energy-efficient transformers are specifically designed to meet the energy efficiency standards set forth in U.S. DOE 10 CFR Part 431. Compliant transformers are optimized to offer maximum efficiency at 50% of nameplate rating. Transformers that are currently specifically excluded from the scope of DOE 10 CFR Part 431 include: ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Liquid-filled transformers below 10 kVA Dry-type transformers below 15 kVA AC and DC drives transformers Rectifier transformers designed for high harmonics Autotransformers Non-distribution transformers, such as UPS transformers Special impedance or regulation transformers Regulating transformers Sealed and non-ventilated transformers Machine tool transformers Welding transformers Transformers with tap ranges greater than 15% Transformers with a frequency other than 60 Hz Grounding transformers Testing transformers DOE 10 CFR Part 431 Efficiency Levels Tables of Energy Efficiency Dry-Type Distribution Transformers— 20–45 kV BIL Single-Phase Three-Phase kVA Efficiency kVA Efficiency 15 98.10 15 97.50 25 98.33 30 97.90 37.5 98.49 45 98.10 50 98.60 75 98.33 75 98.73 112.5 98.49 100 98.82 150 98.60 167 98.96 225 98.73 250 99.07 300 98.82 333 99.14 500 98.96 — — 750 99.07 — — 1000 99.14 — — 1500 99.22 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-173 2.5 Transformers Distribution Transformers 2 Features, Benefits and Functions 2 ● 2 ● 2 2 2 2 ● ● 60 Hz operation (except as noted) Short-term overload capability as required by ANSI Meet NEMA ST-20 sound levels Meet federal energy efficiency requirements for dry-type transformers effective as of January 1, 2010 2 2 2 Standards and Certifications ● UL listed Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the International Building Code (IBC) and California Code Title 24. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-174 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Product Description 2 Single-Phase—2010 Energy-Efficient 2 2 2400 Volts to 120/240 Volts—Aluminum Windings Full Capacity Taps kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 25 2 at +2.5% 2 at –2.5% 150 NH6 — — Included T42D11S25E3R 37.5 2 at +2.5% 2 at –2.5% 150 NH3 — — Included T42D11S37E3R 50 2 at +2.5% 2 at –2.5% 150 NH3 — — Included T42D11S50E3R 75 2 at +2.5% 2 at –2.5% 150 NH3 — — Included T42D11S75E3R 100 2 at +2.5% 2 at –2.5% 150 NH4 — — Included T42D11S99E3R 167 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included T42D11S67E3R 25 2 at +2.5% 2 at –2.5% 115 NH6 — — Included T42D11F25E3R 37.5 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T42D11F37E3R 50 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T42D11F50E3R 75 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T42D11F75E3R 100 2 at +2.5% 2 at –2.5% 115 NH4 — — Included T42D11F99E3R 167 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included T42D11F67E3R 25 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T42D11B25E3R 37.5 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T42D11B37E3R 50 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T42D11B50E3R 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included T42D11B75E3R 100 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included T42D11B99E3R 167 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included T42D11B67E3R 2 2 2 2 2 2 2 2 2 2 2 2 2 4160 Volts to 120/240 Volts—Aluminum Windings Full Capacity Taps kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 25 2 at +2.5% 2 at –2.5% 150 NH6 — — Included T46D11S25E3R 37.5 2 at +2.5% 2 at –2.5% 150 NH3 — — Included T46D11S37E3R 50 2 at +2.5% 2 at –2.5% 150 NH3 — — Included T46D11S50E3R 75 2 at +2.5% 2 at –2.5% 150 NH3 — — Included T46D11S75E3R 100 2 at +2.5% 2 at –2.5% 150 NH4 — — Included T46D11S99E3R 167 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included T46D11S67E3R 25 2 at +2.5% 2 at –2.5% 115 NH6 — — Included T46D11F25E3R 37.5 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T46D11F37E3R 50 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T46D11F50E3R 2 Catalog Number 75 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T46D11F75E3R 100 2 at +2.5% 2 at –2.5% 115 NH4 — — Included T46D11F99E3R 167 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included T46D11F67E3R 25 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T46D11B25E3R 37.5 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T46D11B37E3R 50 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T46D11B50E3R 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included T46D11B75E3R 100 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included T46D11B99E3R 167 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included T46D11B67E3R 2 2 2 2 2 2 2 2 2 2 Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-175 2.5 2 Transformers Distribution Transformers Single-Phase—2010 Energy-Efficient 2 2400 Volts to 120/240 Volts—Copper Windings 2 kVA FCAN 25 2 at +2.5% 2 at –2.5% 37.5 2 at +2.5% 2 at –2.5% 2 50 2 at +2.5% 2 at –2.5% 2 75 2 at +2.5% 100 Full Capacity Taps Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 150 NH6 — — Included T42D11S25CUE3R 150 NH3 — — Included T42D11S37CUE3R 150 NH3 — — Included T42D11S50CUE3R 2 at –2.5% 150 NH3 — — Included T42D11S75CUE3R 2 at +2.5% 2 at –2.5% 150 NH4 — — Included T42D11S99CUE3R 2 167 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included T42D11S67CUE3R 25 2 at +2.5% 2 at –2.5% 115 NH6 — — Included T42D11F25CUE3R 2 37.5 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T42D11F37CUE3R 2 50 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T42D11F50CUE3R 75 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T42D11F75CUE3R 2 100 2 at +2.5% 2 at –2.5% 115 NH4 — — Included T42D11F99CUE3R 167 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included T42D11F67CUE3R 2 25 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T42D11B25CUE3R 37.5 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T42D11B37CUE3R 2 50 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T42D11B50CUE3R 2 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included T42D11B75CUE3R 100 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included T42D11B99CUE3R 167 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included T42D11B67CUE3R 2 2 FCBN ºC Temp. Rise 2 4160 Volts to 120/240 Volts—Copper Windings 2 kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 25 2 at +2.5% 2 at –2.5% 150 NH6 — — Included T46D11S25CUE3R 2 37.5 2 at +2.5% 2 at –2.5% 150 NH3 — — Included T46D11S37CUE3R 50 2 at +2.5% 2 at –2.5% 150 NH3 — — Included T46D11S50CUE3R 2 75 2 at +2.5% 2 at –2.5% 150 NH3 — — Included T46D11S75CUE3R 100 2 at +2.5% 2 at –2.5% 150 NH4 — — Included T46D11S99CUE3R 2 167 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included T46D11S67CUE3R 25 2 at +2.5% 2 at –2.5% 115 NH6 — — Included T46D11F25CUE3R 2 37.5 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T46D11F37CUE3R 2 50 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T46D11F50CUE3R 75 2 at +2.5% 2 at –2.5% 115 NH3 — — Included T46D11F75CUE3R 2 100 2 at +2.5% 2 at –2.5% 115 NH4 — — Included T46D11F99CUE3R 167 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included T46D11F67CUE3R 2 25 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T46D11B25CUE3R 37.5 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T46D11B37CUE3R 2 50 2 at +2.5% 2 at –2.5% 80 NH3 — — Included T46D11B50CUE3R 2 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included T46D11B75CUE3R 100 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included T46D11B99CUE3R 167 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included T46D11B67CUE3R 2 2 Full Capacity Taps Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 V2-T2-176 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Three-Phase—2010 Energy-Efficient 2 2 2400 Delta Volts to 480Y/277 Volts—Copper Windings Full Capacity Taps kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 45 2 at +2.5% 2 at –2.5% 150 NH3 — — Included V42D47T45CUE3R 75 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V42D47T75CUE3R 112.5 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V42D47T12CUE3R 150 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D47T49CUE3R 225 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D47T22CUE3R 300 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D47T33CUE3R 500 2 at +2.5% 2 at –2.5% 150 NJ2 — — Included V42D47T55CUE3R 750 2 at +2.5% 2 at –2.5% 150 NJ3 — — Included V42D47T77CUE3R 45 2 at +2.5% 2 at –2.5% 115 NH3 — — Included V42D47F45CUE3R 75 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V42D47F75CUE3R 112.5 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V42D47F12CUE3R 150 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D47F49CUE3R 225 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D47F22CUE3R 300 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D47F33CUE3R 500 2 at +2.5% 2 at –2.5% 115 NJ2 — — Included V42D47F55CUE3R 750 2 at +2.5% 2 at –2.5% 115 NJ3 — — Included V42D47F77CUE3R 45 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V42D47B45CUE3R 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V42D47B75CUE3R 112.5 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D47B12CUE3R 150 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D47B49CUE3R 225 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D47B22CUE3R 300 2 at +2.5% 2 at –2.5% 80 NJ2 — — Included V42D47B33CUE3R 500 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V42D47B55CUE3R 750 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V42D47B77CUE3R 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-177 2.5 2 Transformers Distribution Transformers Three-Phase—2010 Energy-Efficient 2 4160 Delta Volts to 480Y/277 Volts—Copper Windings 2 kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 45 2 at +2.5% 2 at –2.5% 150 NH3 — — Included V46D47T45CUE3R 75 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V46D47T75CUE3R 2 112.5 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V46D47T12CUE3R 2 150 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D47T49CUE3R 225 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D47T22CUE3R 2 300 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D47T33CUE3R 500 2 at +2.5% 2 at –2.5% 150 NJ2 — — Included V46D47T55CUE3R 2 750 2 at +2.5% 2 at –2.5% 150 NJ3 — — Included V46D47T77CUE3R 2 45 2 at +2.5% 2 at –2.5% 115 NH3 — — Included V46D47F45CUE3R 75 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V46D47F75CUE3R 2 112.5 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V46D47F12CUE3R 150 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D47F49CUE3R 2 225 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D47F22CUE3R 300 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D47F33CUE3R 2 500 2 at +2.5% 2 at –2.5% 115 NJ2 — — Included V46D47F55CUE3R 2 750 2 at +2.5% 2 at –2.5% 115 NJ3 — — Included V46D47F77CUE3R 45 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V46D47B45CUE3R 2 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V46D47B75CUE3R 112.5 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D47B12CUE3R 2 150 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D47B49CUE3R 2 Full Capacity Taps 225 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D47B22CUE3R 2 300 2 at +2.5% 2 at –2.5% 80 NJ2 — — Included V46D47B33CUE3R 2 500 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V46D47B55CUE3R 750 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V46D47B77CUE3R 2 2 Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 V2-T2-178 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Three-Phase—2010 Energy-Efficient 2 2 2400 Delta Volts to 208Y/120 Volts—Copper Windings Full Capacity Taps kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield 2 Catalog Number 45 2 at +2.5% 2 at –2.5% 150 NH3 — — Included V42D28T45CUE3R 75 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V42D28T75CUE3R 112.5 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V42D28T12CUE3R 150 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D28T49CUE3R 225 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D28T22CUE3R 300 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D28T33CUE3R 500 2 at +2.5% 2 at –2.5% 150 NJ2 — — Included V42D28T55CUE3R 750 2 at +2.5% 2 at –2.5% 150 NJ3 — — Included V42D28T77CUE3R 45 2 at +2.5% 2 at –2.5% 115 NH3 — — Included V42D28F45CUE3R 75 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V42D28F75CUE3R 112.5 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V42D28F12CUE3R 150 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D28F49CUE3R 225 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D28F22CUE3R 300 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D28F33CUE3R 500 2 at +2.5% 2 at –2.5% 115 NJ2 — — Included V42D28F55CUE3R 750 2 at +2.5% 2 at –2.5% 115 NJ3 — — Included V42D28F77CUE3R 45 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V42D28B45CUE3R 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V42D28B75CUE3R 112.5 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D28B12CUE3R 150 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D28B49CUE3R 225 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D28B22CUE3R 300 2 at +2.5% 2 at –2.5% 80 NJ2 — — Included V42D28B33CUE3R 500 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V42D28B55CUE3R 750 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V42D28B77CUE3R 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-179 2.5 2 Transformers Distribution Transformers Three-Phase—2010 Energy-Efficient 2 4160 Delta Volts to 208Y/120 Volts—Copper Windings 2 kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 45 2 at +2.5% 2 at –2.5% 150 NH3 — — Included V46D28T45CUE3R 75 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V46D28T75CUE3R 2 112.5 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V46D28T12CUE3R 2 150 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D28T49CUE3R 225 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D28T22CUE3R 2 300 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D28T33CUE3R 500 2 at +2.5% 2 at –2.5% 150 NJ2 — — Included V46D28T55CUE3R 2 750 2 at +2.5% 2 at –2.5% 150 NJ3 — — Included V46D28T77CUE3R 2 45 2 at +2.5% 2 at –2.5% 115 NH3 — — Included V46D28F45CUE3R 75 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V46D28F75CUE3R 2 112.5 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V46D28F12CUE3R 150 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D28F49CUE3R 2 225 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D28F22CUE3R 300 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D28F33CUE3R 2 500 2 at +2.5% 2 at –2.5% 115 NJ2 — — Included V46D28F55CUE3R 2 750 2 at +2.5% 2 at –2.5% 115 NJ3 — — Included V46D28F77CUE3R 45 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V46D28B45CUE3R 2 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V46D28B75CUE3R 112.5 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D28B12CUE3R 2 150 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D28B49CUE3R V46D28B22CUE3R 2 Full Capacity Taps 225 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included 2 300 2 at +2.5% 2 at –2.5% 80 NJ2 — — Included V46D28B33CUE3R 2 500 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V46D28B55CUE3R 750 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V46D28B77CUE3R 2 2 Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 V2-T2-180 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Three-Phase—2010 Energy-Efficient 2 2 2400 Delta Volts to 480Y/277 Volts—Aluminum Windings Full Capacity Taps kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 45 2 at +2.5% 2 at –2.5% 150 NH3 — — Included V42D47T45E3R 75 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V42D47T75E3R 112.5 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V42D47T12E3R 150 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D47T49E3R 225 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D47T22E3R 300 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D47T33E3R 500 2 at +2.5% 2 at –2.5% 150 NJ2 — — Included V42D47T55E3R 750 2 at +2.5% 2 at –2.5% 150 NJ3 — — Included V42D47T77E3R 45 2 at +2.5% 2 at –2.5% 115 NH3 — — Included V42D47F45E3R 75 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V42D47F75E3R 112.5 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V42D47F12E3R 150 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D47F49E3R 225 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D47F22E3R 300 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D47F33E3R 500 2 at +2.5% 2 at –2.5% 115 NJ2 — — Included V42D47F55E3R 750 2 at +2.5% 2 at –2.5% 115 NJ3 — — Included V42D47F77E3R 45 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V42D47B45E3R 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V42D47B75E3R 112.5 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D47B12E3R 150 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D47B49E3R 225 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D47B22E3R 300 2 at +2.5% 2 at –2.5% 80 NJ2 — — Included V42D47B33E3R 500 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V42D47B55E3R 750 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V42D47B77E3R 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-181 2.5 2 Transformers Distribution Transformers Three-Phase—2010 Energy-Efficient 2 4160 Delta Volts to 480Y/277 Volts—Aluminum Windings 2 kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 45 2 at +2.5% 2 at –2.5% 150 NH3 — — Included V46D47T45E3R 75 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V46D47T75E3R 2 112.5 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V46D47T12E3R 2 150 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D47T49E3R 225 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D47T22E3R 2 300 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D47T33E3R 500 2 at +2.5% 2 at –2.5% 150 NJ2 — — Included V46D47T55E3R 2 750 2 at +2.5% 2 at –2.5% 150 NJ3 — — Included V46D47T77E3R 2 45 2 at +2.5% 2 at –2.5% 115 NH3 — — Included V46D47F45E3R 75 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V46D47F75E3R 2 112.5 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V46D47F12E3R 150 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D47F49E3R 2 225 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D47F22E3R 300 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D47F33E3R 2 500 2 at +2.5% 2 at –2.5% 115 NJ2 — — Included V46D47F55E3R 2 750 2 at +2.5% 2 at –2.5% 115 NJ3 — — Included V46D47F77E3R 45 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V46D47B45E3R 2 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V46D47B75E3R 112.5 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D47B12E3R 2 150 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D47B49E3R 225 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D47B22E3R 300 2 at +2.5% 2 at –2.5% 80 NJ2 — — Included V46D47B33E3R 500 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V46D47B55E3R 750 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V46D47B77E3R 2 2 2 2 2 Full Capacity Taps Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 V2-T2-182 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Distribution Transformers 2.5 Three-Phase—2010 Energy-Efficient 2 2 2400 Delta Volts to 208Y/120 Volts—Aluminum Windings Full Capacity Taps kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 45 2 at +2.5% 2 at –2.5% 150 NH3 — — Included V42D28T45E3R 75 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V42D28T75E3R 112.5 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V42D28T12E3R 150 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D28T49E3R 225 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D28T22E3R 300 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V42D28T33E3R 500 2 at +2.5% 2 at –2.5% 150 NJ2 — — Included V42D28T55E3R 750 2 at +2.5% 2 at –2.5% 150 NJ3 — — Included V42D28T77E3R 45 2 at +2.5% 2 at –2.5% 115 NH3 — — Included V42D28F45E3R 75 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V42D28F75E3R 112.5 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V42D28F12E3R 150 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D28F49E3R 225 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D28F22E3R 300 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V42D28F33E3R 500 2 at +2.5% 2 at –2.5% 115 NJ2 — — Included V42D28F55E3R 750 2 at +2.5% 2 at –2.5% 115 NJ3 — — Included V42D28F77E3R 45 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V42D28B45E3R 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V42D28B75E3R 112.5 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D28B12E3R 150 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D28B49E3R 225 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V42D28B22E3R 300 2 at +2.5% 2 at –2.5% 80 NJ2 — — Included V42D28B33E3R 500 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V42D28B55E3R 750 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V42D28B77E3R 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-183 2.5 2 Transformers Distribution Transformers Three-Phase—2010 Energy-Efficient 2 4160 Delta Volts to 208Y/120 Volts—Aluminum Windings 2 kVA FCAN FCBN ºC Temp. Rise Frame Wiring Diagram Number Weight Lbs (kg) Weathershield Catalog Number 2 45 2 at +2.5% 2 at –2.5% 150 NH3 — — Included V46D28T45E3R 75 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V46D28T75E3R 2 112.5 2 at +2.5% 2 at –2.5% 150 NH4 — — Included V46D28T12E3R 2 150 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D28T49E3R 225 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D28T22E3R 2 300 2 at +2.5% 2 at –2.5% 150 NJ1 — — Included V46D28T33E3R 500 2 at +2.5% 2 at –2.5% 150 NJ2 — — Included V46D28T55E3R 2 750 2 at +2.5% 2 at –2.5% 150 NJ3 — — Included V46D28T77E3R 2 45 2 at +2.5% 2 at –2.5% 115 NH3 — — Included V46D28F45E3R 75 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V46D28F75E3R 2 112.5 2 at +2.5% 2 at –2.5% 115 NH4 — — Included V46D28F12E3R 150 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D28F49E3R 2 225 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D28F22E3R 300 2 at +2.5% 2 at –2.5% 115 NJ1 — — Included V46D28F33E3R 2 500 2 at +2.5% 2 at –2.5% 115 NJ2 — — Included V46D28F55E3R 2 750 2 at +2.5% 2 at –2.5% 115 NJ3 — — Included V46D28F77E3R 45 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V46D28B45E3R 2 75 2 at +2.5% 2 at –2.5% 80 NH4 — — Included V46D28B75E3R 112.5 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D28B12E3R 2 150 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D28B49E3R 225 2 at +2.5% 2 at –2.5% 80 NJ1 — — Included V46D28B22E3R 300 2 at +2.5% 2 at –2.5% 80 NJ2 — — Included V46D28B33E3R 500 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V46D28B55E3R 750 2 at +2.5% 2 at –2.5% 80 NJ3 — — Included V46D28B77E3R 2 2 2 2 Full Capacity Taps Note Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216. 2 2 2 2 2 2 2 2 2 2 2 V2-T2-184 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Transformer Standards, Technical Data and Accessories Dry-Type Distribution Transformers 2.6 Contents Description Standards and Certifications . . . . . . . . . . . . . . . . . Catalog Number Selection. . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Options and Accessories. . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . Glossary of Transformer Terms . . . . . . . . . . . . . . . Frequently Asked Questions About Transformers . Page V2-T2-186 V2-T2-187 V2-T2-189 V2-T2-191 V2-T2-195 V2-T2-211 V2-T2-214 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-185 2.6 2 Transformers Transformer Standards, Technical Data and Accessories Standards and Certifications Eaton dry-type distribution transformers are approved, listed, recognized or may comply with the following standards. 2 2 2 2 Engineering Standards Catalog Product Name UL Standard 1 UL/cUL File Number UL Listed Control Number cUL Energy Efficiency File Number CSA File Number Insulation System Temp/ºC kVA SinglePhase kVA ThreePhase Applicable IEC Standard Industrial Control Transformer MTE 5085 E46323 702X — LR27533 105 0.025–1.5 N/A 61558 2 MTK 5085 E46323 702X — LR27533 180 0.05–5 N/A 61558 2 AP 5085 E10156 591H — — 180 3–10 N/A 61558 2 AP 1561 E78389 591H — — 180 15 N/A 61558 EP 5085 E10156 591H — LR60545 180 0.05–10 N/A 61558 2 EP 1561 E78389 591H EV157 2 LR60545 3 180 15–50 N/A 61558 4 / 726 5 EPT 5085 E10156 591H — LR60545 180 N/A 3–9 61558 6 / 726 7 Encapsulated Transformer 2 EPT 1561 E78389 591H EV157 8 LR60545 9 180 N/A 15–75 726 2 MPC 1062 E53449 591H — LR60546 180 3–25 15–30 — Ventilated Transformer 60726 2 DS-3 1561 E78389 591H — — 220 15–167 N/A DT-3 1561 E78389 591H — — 220 N/A 15–750 60726 2 KT 1561 E78389 591H — — 220 N/A 9–500 N/A 2 Notes 1 UL 5085 replaces UL 506. 2 Applies to 25–50 kVA. 3 Applies to 25 kVA. 4 Applies to 15–25 kVA. 5 Applies to 37.5 kVA. 6 Applies to 3 kVA. 7 Applies to 5–9 kVA. 8 Applies to 30–75 kVA. 9 Applies to 30 kVA. 2 2 2 2 2 2 2 In addition to the above standards, Eaton dry-type distribution transformers are also manufactured in compliance with the applicable standards listed below. Not all of the following standards apply to every transformer. NEC: National Electrical Code NEMA ST-1: Specialty Transformers (C89.1) (control transformers). NEMA ST-20: General-Purpose Transformers. NEMA TP-1: Guide for Determining Energy Efficiency for Distribution Transformers. NEMA 250: Enclosures for Electrical Equipment (1000 volts maximum). IEEE C57.12.01: General Requirements for Dry-Type Distribution and Power Transformers (including those with solidcast and/or resin-encapsulated windings). ANSI C57.12.70: Terminal Markings and Connections for Distribution and Power Transformers. ANSI C57.12.91: Standard Test Code for Dry-Type Distribution and Power Transformers. CSA C22 No. 47-M90: Air-Cooled Transformers (Dry-Type). CSA C9-M1981: Dry-Type Transformers. CSA C22.2 No. 66: Specialty Transformers. CSA 802-94: Maximum Losses for Distribution, Power and Dry-Type Transformers. NEMA TP-2: Standard Test Method for Measuring the Energy Consumption of Distribution Transformers. NEMA TP-3 2 2 2 2 2 2 2 2 2 V2-T2-186 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.6 Transformers Transformer Standards, Technical Data and Accessories Catalog Number Selection 2 General-Purpose, Energy-Efficient, Mini–Power Center, Shielded Isolation, Nonlinear, Buck-Boost, Marine Duty Transformers— Example: S20N11S05A T S 20 N 11 S 05 A Prefix Options C = CSA labeled ventilated transformer Marine Duty QS = EPM marine (1-Ph encapsulated) LY = EPTM Marine (3-Ph encapsulated) RT = DS-3M marine (1-Ph ventilated) MV = DT-3M marine (3-Ph ventilated) S Y T V P Z X = = = = = = = Type EP (single-phase encapsulated) EPT (three-phase encapsulated) DS-3 (single-phase ventilated) DT-3 (three-phase ventilated) Mini–power center Class 1 Division 2 Groups A, B, C, D Harmonic mitigating (three-phase ventilated) Nonlinear H = KT-4 (three-phase ventilated) B = KT-9 (three-phase ventilated) N = KT-13 (three-phase ventilated) G = KT-20 (three-phase ventilated) J = KT-30 (three-phase ventilated) A = KT-40 (three-phase ventilated) K = KT-50 (three-phase ventilated) HT = KT-4 (single-phase ventilated) NT = KT-13 (single-phase ventilated) GT = KT-20 (single-phase ventilated) D E F G J K L M N R P Primary Voltage = 110 x 220 = 120 = 120 x 240 = 208 = 200 = 220 = 230 = 240 = 240 x 480 = 277 = 380 = 400 = 416 = 440 = 450 = 480 = 575 = 600 = 2400 = 4160 = 4800 = Export model = 120/208/240/277 = = = = = = = = = = = T = U = W= X = Notes 1 Model number is not used on newly designed/redesigned transformers. 2 Copper windings. 3 Grade 304 stainless steel enclosure (does not imply a NEMA 4X rating). 4 Open type core and coil assembly. 5 Totally enclosed non-ventilated DS-3 or DT-3. 6 50/60 Hz. 7 Low sound design. LS47 indicates low sound equal to 47 dB; LS42 indicates 42 dB. Taps 2 at +2.5%, 2 at –2.5% 1 at +5%, 1 at –5% 1 at –10% 2 at –5% 4 at –2.5% 1 at –10% x 2 at –5% 2 at –5% x 4 at –2.5% 2 at +2.5%, 4 at –2.5% None 1 at +5%, 2 at –5% 1 at +5%, 2 at –5% x 2 at +2.5%, 4 at –2.5% 1 at +4.2%, 1 at –4.2% 1 at +2.5%, 3 at –2.5% 1 at +3.5%, 1 at –3.5% 2 at +3.1%, 2 at –3.1% 81 = 85 = 82 = 83 = 26 = 51 = 76 = 01 = 16 = 02 = 0.05 0.075 0.10 0.15 0.25 0.50 0.75 1 1.5 2 03 = 05 = 06 = 07 = 09 = 10 = 15 = 21 = 25 = 30 = 3 5 6 7.5 9 10 15 22.5 25 30 kVA 37 = 37.5 45 = 45 50 = 50 75 = 75 99 = 100 12 = 112.5 49 = 150 67 = 167 22 = 225 52 = 33 = 54 = 55 = 60 = 77 = 11 = 14 = 250 300 333 500 600 750 1000 1500 Temperature Rise T = 150°C rise with 220°C J = 80°C rise with 220°C insulation system insulation system (ventilated) (ventilated) F = 115°C rise with 220°C P = 115°C rise with 130°C insulation system insulation system (ventilated) (encapsulated) B = 80°C rise with 220°C S = 115°C rise with 180°C insulation system insulation system (ventilated) (encapsulated and H = 130°C rise with 200°C MPC) insulation system L = 80°C rise with 180°C (ventilated) insulation system G = 115°C rise with 200°C (encapsulated and insulation system MPC) (ventilated) 04 06 08 14 12 10 11 54 19 28 29 25 31 26 22 64 24 = = = = = = = = = = = = = = = = = 2 2 Suffix Options 13 12 10 29 72 25 23 24 20 27 38 39 43 44 45 48 57 60 42 46 49 40 54 2 A...Y = CU = SS = ZZ = NV = X = LS_ _ = AF = TR = SR = CE = T = EE = NON = POS = NEG = THR = E3 = SS4X = Z = S6 = I2 = I3 = I4 = N3 = 1 2 2 2 3 4 2 5 6 7 2 8 9 2 j k l 2 m n 2 o p q 2 r s 2 t BK BL BM BN BO 2 2 2 Secondary Voltage 12/24 20 = 240 x 480 16/32 21 = 240/480 24/48 27 = 277 110/220 38 = 380 delta 120 37 = 380Y/220 120 x 240 34 = 400Y/231 120/240 51 = 416Y/240 127/254 35 = 440Y/254 190Y/110 62 = 460Y/266 208Y/120 47 = 480Y/277 208 48 = 480 delta 220 delta 60 = 600 delta 220Y/127 61 = 600Y/346 220 delta/110 midtap 42 = 2400 240 delta/120 midtap 41 = 4160Y/2400 240Y/139 46 = 4160 240 delta 49 = 4800 2 2 2 2 2 2 2 2 8 9 j k l m Fungus proof. Certified test report of standard production tests for the specific serial number to be shipped. Certified sound level report. CE Marked. Thermal indicator embedded in center coil. Suffix “TT” indicates two thermal indicators of different temperature ratings, are installed. NEMA TP-1 efficient. n o p q r s t BK BL BM BN BO 0° phase-shift (used with HMTs). +15° phase-shift (used with HMTs). –15° phase-shift (used with HMTs). –30° phase-shift (used with HMTs). CSL3 DOE 2007 energy-efficient. NEMA 4X Grade 304 stainless steel enclosure. Easy install base. Grade 316 stainless steel enclosure (does not imply NEMA 4X rating). Integral 2-inch infrared viewing window. Integral 3-inch infrared viewing window. Integral 4-inch infrared viewing window. NEMA Premium® Efficient. For Eaton’s industrial control transformers catalog number selection, see Page V2-T2-188. Contact your local Eaton sales office for voltage combinations not shown. Use table for catalog number breakdown only. Do not use to create catalog numbers because all combinations may not be valid. Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2 2 2 2 2 2 V2-T2-187 2.6 2 Transformers Transformer Standards, Technical Data and Accessories Motor Drive Isolation Transformers—Example: MD145E89B MD 145 E 89 B 2 2 2 Type MD = DT-3 HD = KT-4 ND = KT-13 2 2 2 2 075 11 14 20 27 34 40 51 63 75 93 118 145 = = = = = = = = = = = = = 7.5 11 14 20 27 34 40 51 63 75 93 118 145 kVA 175 = 220 = 275 = 330 = 440 = 550 = 660 = 770 = 880 = 1000 = 1250 = 1500 = 175 220 275 330 440 550 660 770 880 1000 1250 1500 Taps 1 D = 2 at +2.5%, 2 at –2.5% E = 1 at +5%, 1 at –5% 2 2 2 2 2 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 = = = = = = = = = = = = = = = = = Voltage Primary 230 delta 208 delta 240 delta 208 delta 208 delta 208 delta 230 delta 230 delta 230 delta 460 delta 460 delta 460 delta 575 delta 575 delta 575 delta 575 delta 600 delta Notes 1 For other tap combinations, contact your local Eaton sales office. Contact your local Eaton sales office for voltage combinations not shown. Use table for catalog number breakdown only. Do not use to create catalog numbers because all combinations may not be valid. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-188 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Secondary 208Y/120 208Y/120 480 delta 230Y/133 460Y/266 480 delta 230Y/133 460Y/266 575Y/332 230Y/133 460Y/266 575Y/332 230Y/133 460Y/266 575Y/332 480 delta 480 delta Y = ES = CU= F = B = X = Suffix Options Encapsulated (Type EPT) design Electrostatic shield Copper windings 115°C rise 80°C rise 50/60 Hz 2.6 Transformers Transformer Standards, Technical Data and Accessories Product Selection 2 Single-Phase Transformers How to Select Single-Phase Units 1. Determine the primary (source) voltage—the voltage presently available. 2. Determine the secondary (load) voltage—the voltage needed at the load. 3. Determine the kVA load: – If the load is defined in kVA, a transformer can be selected from the tabulated data – If the load rating is given in amperes, determine the load kVA from the chart (below right). To determine kVA when volts and amperes are known, use the formula: Volts Amperes kVA = ---------------------------------------1000 – If the load is an AC motor, determine the minimum transformer kVA from the chart at the right – Select a transformer rating equal to or greater than the load kVA. 4. Define tap arrangements needed. 2 Single-Phase AC Motors Full Load Amperes Horsepower 115 Volts 208 Volts 220 Volts 230 Volts Minimum Transformer kVA 1 1/6 4.4 2.4 2.3 2.2 0.53 1/4 5.8 3.2 3.0 2.9 0.70 1/3 7.2 4.0 3.8 3.6 0.87 1/2 9.8 5.4 5.1 4.9 1.18 3/4 13.8 7.6 7.2 6.9 1.66 1 16 8.8 8.4 8 1.92 1-1/2 20 11.0 10.4 10 2.40 2 24 13.2 12.5 12 2.88 3 34 18.7 17.8 17 4.10 5 56 30.8 29.3 28 6.72 7-1/2 80 44 42 40 9.6 10 100 55 52 50 12.0 2 2 2 2 2 2 2 Voltage Using the above procedure, select the transformer from the listings in this catalog. 2 2 Full Load Current in Amperes—Single-Phase Circuits 5. Define temperature rise. 2 kVA 120 208 220 240 277 480 600 2400 4160 0.25 2.0 1.2 1.1 1.0 0.9 0.5 0.4 0.10 0.06 0.50 4.2 2.4 2.3 2.1 1.8 1.0 0.8 0.21 0.12 0.75 6.3 3.6 3.4 3.1 2.7 1.6 1.3 0.31 0.18 1 8.3 4.8 4.5 4.2 3.6 2.1 1.7 0.42 0.24 1.5 12.5 7.2 6.8 6.2 5.4 3.1 2.5 0.63 0.36 2 16.7 9.6 9.1 8.3 7.2 4.2 3.3 0.83 0.48 3 25 14.4 13.6 12.5 10.8 6.2 5.0 1.2 0.72 5 41 24.0 22.7 20.8 18.0 10.4 8.3 2.1 1.2 7.5 62 36 34 31 27 15.6 12.5 3.1 1.8 10 83 48 45 41 36 20.8 16.7 4.2 2.4 15 125 72 68 62 54 31 25 6.2 3.6 25 208 120 114 104 90 52 41 10.4 6.0 37.5 312 180 170 156 135 78 62 15.6 9.0 50 416 240 227 208 180 104 83 20.8 12.0 75 625 360 341 312 270 156 125 31.3 18.0 100 833 480 455 416 361 208 166 41.7 24.0 167 1391 802 759 695 602 347 278 69.6 40.1 Notes 1 If motors are started more than once per hour, increase minimum transformer kVA by 20%. When motor service factor is greater than 1, increase full load amperes proportionally. Example: If service factor is 1.15, increase above ampere values by 15%. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-189 2.6 Transformers Transformer Standards, Technical Data and Accessories 2 Three-Phase Transformers 2 How to Select Three-Phase Units 1. Determine the primary (source) voltage—the voltage presently available. 2 2 2 2 2 Three-Phase AC Motors Full Load Amperes Horsepower 2. Determine the secondary (load) voltage—the voltage needed at the load. 3. Determine the kVA load: – If the load is defined in kVA, a transformer can be selected from the tabulated data – If the load rating is given in amperes, determine the load kVA from the chart (below right). To determine kVA when volts and amperes are known, use the formula: Minimum Transformer 208 Volts 230 Volts 380 Volts 460 Volts 575 Volts kVA 1 0.5 2.2 2.0 1.2 1.0 0.8 0.9 3/4 3.1 2.8 1.7 1.4 1.1 1.2 1 4.0 3.6 2.2 1.8 1.4 1.5 1.5 5.7 5.2 3.1 2.6 2.1 2.1 2 7.5 6.8 4.1 3.4 2.7 2.7 3 10.7 9.6 5.8 4.8 3.9 3.8 5 16.7 15.2 9.2 7.6 6.1 6.3 7.5 24 22 14 11 9 9.2 10 31 28 17 14 11 11.2 15 46 42 26 21 17 16.6 20 59 54 33 27 22 21.6 25 75 68 41 34 27 26.6 30 88 80 48 40 32 32.4 40 114 104 63 52 41 43.2 50 143 130 79 65 52 52 60 170 154 93 77 62 64 75 211 192 116 96 77 80 100 273 248 150 124 99 103 2 125 342 312 189 156 125 130 2 150 396 360 218 180 144 150 200 528 480 291 240 192 200 2 2 2 2 2 2 Volts Amperes 1.732 kVA = -----------------------------------------------------------1000 – If the load is an AC motor, determine the minimum transformer kVA from the chart at the right – Select a transformer rating equal to or greater than the load kVA 4. Define tap arrangements needed. 5. Define temperature rise. Using the above procedure, select the transformer from the listings in this catalog. 2 Full Load Current in Amperes—Three-Phase Circuits 2 kVA 208 240 380 480 600 2400 4160 3 6 9 8.3 16.6 25 7.2 14.4 21.6 4.6 9.1 13.7 3.6 7.2 10.8 2.9 5.8 8.6 0.72 1.4 2.2 0.42 0.83 1.2 15 22.5 30 41.7 62.4 83.4 36.1 54.1 72.3 22.8 34.2 45.6 18.0 27.1 36.1 14.4 21.6 28.9 3.6 5.4 7.2 2.1 3.1 4.2 37.5 45 50 104 124 139 90.3 108 120 57.0 68.4 76 45.2 54.2 60.1 36.1 43.4 48.1 9.0 10.8 12.0 5.2 6.3 6.9 75 112.5 150 208 312 416 180 270 360 114 171 228 90 135 180 72 108 144 18.0 27.1 36.1 10.4 15.6 20.8 225 300 500 624 832 1387 541 721 1202 342 456 760 270 360 601 216 288 481 54.2 72.2 120 31.3 41.6 69.4 750 1000 2084 2779 1806 2408 1140 1519 903 1204 723 963 180 241 104 139 Voltage 2 2 2 2 2 2 2 2 Notes 1 If motors are started more than once per hour, increase minimum transformer kVA by 20%. 2 When motor service factor is greater than 1, increase full load amperes proportionally. Example: If service factor is 1.15, increase above ampere values by 15%. 2 2 2 2 V2-T2-190 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.6 Transformers Transformer Standards, Technical Data and Accessories Options and Accessories 2 (Order separately) Weathershield Kit Weathershield Kit 2 Terminal Extension Kit A weathershield kit consisting of a front and rear cover shield must be installed on all ventilated dry-type distribution transformers when the unit is located outdoors. The shields protect the transformer top ventilation openings against rain but allow for proper ventilation. Field installation hardware is not required. Refer to specific transformer listing for selection of weathershield kit. Proper installation provides a NEMA 3R rating. Note: For 316 stainless steel, add the suffix ‘S’ to the catalog number. A terminal extension kit is used to allow front access to the rear terminals on most 500 and 750 kVA transformers (transformers on frames 919 and 920) when insufficient space is available at the rear of the transformer. Eaton recommends a minimum 6-inch clearance from the wall to maintain proper ventilation. Terminal Extension Kit Fits Frame Size(s) 1 Bus Material Catalog Number 919 Aluminum EXT55AL 919 Copper EXT55CU 920 Aluminum EXT77AL 920 Copper EXT77CU Fits Frame Size(s) 1 Catalog Number 2 809, 810, 811, 816, 817, 818 WS11 814, 814E WS13 815 WS15 819, 820 WS16 808, 908, 909, 910, 911, 912, 910A, 911A, 912A WS31 912B, 912Z, 912D WS38 812, 813, 913A, 913B, 914A, 915A, 916, 914B, 915B WS33 Wall-mounting brackets are used to wall-mount ventilated transformers. This bracket allows the transformer to be installed with the proper clearance, as recommended by Eaton. 2 2 2 2 2 Wall-Mounting Bracket Weathershield Kit 2 Wall-mounting brackets are compatible with the following frames. 2 2 2 2 Wall-Mounting Bracket Availability Guide Wall-Mounting Bracket WMB01 2 Catalog Number 914D, 915D, 914F, 915F, 914Z, 915Z WS39 916A, 916B, 912Z WS19 917, 918, 918A WS34 919, 920, 919E, 919EX, 920E, 920EX WS35 922 WS36 923 WS37 842 WS45 843 WS43 908, 909, 910, 911, 912, 910A, 911A, 912A, WMB01 912B, 912D, 913A, 913B, 914A, 914B, 914D, 915D, 915A, 915B, 914F, 915F, 912Z, 914Z, 915Z 844 WS44 939, 940 WMB05 939 WS57 942, 943 WMB04 940 WS58 942 WS59 943 WS60 944 WS61 945 WS62 Notes 1 Effective June 1, 2001, frame numbers will have a prefix of FR, e.g., FR819. Dimensions, accessories and so on are still applicable as if the FR did not exist. 2 For Grade 316 stainless steel weathershields, add the suffix “S” to a catalog number, e.g., WS31S. Frame Sizes 1 Type DS-3 (Single-Phase Compatible) 809, 810, 811, 812, 813, 815, 816, 817, 818, 835, 836, 837, 814A, 842 WMB01 2 2 2 Type DT-3, K-Factor, Drive Isolation (Three-Phase Compatible) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-191 2.6 Transformers Transformer Standards, Technical Data and Accessories 2 Terminal Lug Kits for Type DT-3 Transformers 2 Typical Sizing Cable Range Quantity Bolt Size Quantity Catalog Number 15–37.5 kVA single-phase 15–45 kVA three-phase #14–#2 #6–250 kcmil 8 4 1/4-20 x 3/4 8 LKS1 50–75 kVA single-phase 75–112.5 kVA three-phase #6–250 kcmil 12 1/4-20 x 3/4 1/4-20 x 1-3/4 8 8 LKS2 100–167 kVA single-phase 150–300 kVA three-phase #6–250 kcmil #2–600 kcmil 3 22 1/4-20 x 3/4 3/8-16 x 2 3 16 LKS3 500 kVA three-phase #2–600 kcmil 29 3/8-16 x 2 18 LKS4 2 2 2 2 2 Terminal Lugs Hardware Rodent Screens Replacement Parts for Mini–Power Centers Frame Deadfront Cover (Breaker Cover) Front Cover Description Frame Size(s) 1 Catalog Number Rodent screens are used to discourage entry by birds or rodents. 908, 909 RS01 283 47-37503 7074C98H04 910A, 911, 912 RS02 284 47-37503-2 7074C98H01 913B, 914B, 915B RS03 285 47-37503-3 7074C98H02 2 916 RS04 286 47-37503-4 7074C98H02 917, 918, 918A RS05 287 47-37503-5 7074C98H03 2 919, 920, 919E, 919EX, 920E, 920EX RS06 289 47-37459 7074C44H01 916A, 916B RS07 290 47-37459-2 7074C44H02 2 922 RS08 291 47-37459-3 7074C44H03 2 923 RS09 289A 47-42072-1 7074C44H01 814, 821, 814E RS11 290A 47-42072-2 7074C44H02 2 815 RS12 291A 47-42072-3 7074C44H03 816 RS13 2 817, 818 RS14 Notes 1 Effective June 1, 2001, frame numbers will have a prefix of FR, e.g., FR819. Dimensions, accessories and so on are still applicable as if the FR did not exist. 2 2 819, 820 RS15 2 842 RS42 2 843 RS43 844 RS44 2 912B, 912Z, 912D RS16 914D, 915D, 914F, 915F, 914Z, 915Z RS17 2 916Z RS07 2 939 RS57 940 RS58 2 942 RS59 943 RS60 2 944 RS61 945 RS62 Lugs are rated Al/Cu and are suitable for use with either aluminum or copper conductors. 2 2 2 2 2 2 2 2 V2-T2-192 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Transformer Standards, Technical Data and Accessories 2.6 Case Parts for Ventilated Units 2 Front Panel (Upper) Front Panel (Lower) Back Panel (Upper) Back Panel (Lower) Front or Back Panel (Cutout Cover Plate) Top Cover Side Panel (Two Required per Transformer) Bottom 809 7073C16P03 — 7073C16P03 — — 7073C17P01 7073C18P04 7073C14P03 810 7073C16P01 — 7073C16P01 — — 7073C17P01 7073C18P01 7073C14P01 811 7073C16P01 — 7073C16P01 — — 7073C17P01 7073C18P01 7073C14P01 812 7073C16P02 — 7073C16P02 — — 7073C17P02 7073C18P02 7073C14P02 813 7073C16P02 — 7073C16P02 — — 7073C17P02 7073C18P02 7073C14P02 Frame(s) 1 Single-Phase 814, 814E 7073C54P01 — 7073C54P01 — — 7073C17P03 7073C18P05 7073C14P04 815 47-39433 — 47-39433 — — 47-39431 47-39430 47-39429 816 47-40452 — 47-40452 — — 47-40453 47-40451 47-40449 817 47-40457 — 47-40457 — — 47-40458 47-40456 47-40454 818 47-40457 — 47-40457 — — 47-40458 47-40456 47-40454 819 47-40574 — 47-40574 — — 47-40575 47-40573 47-40459 820 47-40574 — 47-40574 — — 47-40575 47-40573 47-40459 842 47-54828-2 — 47-54828-2 — — 47-54829-2 47-54827-2 47-55335-2 843 47-54828-4 — 47-54828-4 — — 47-54829-4 47-54827-4 47-55335-3 844 47-54828-5 — 47-54828-5 — — 47-54829-5 47-54827-5 47-55335-5 2 2 2 2 2 2 2 2 2 2 2 Notes 1 Effective June 1, 2001, frame numbers will have a prefix of FR, e.g., FR819. Dimensions, accessories and so on are still applicable as if the FR did not exist. Parts listed are for standard catalog listed transformers. Units with modifications may require different parts. (Frame number from transformer nameplate required.) Transformer nameplate and UL label are not field replaceable. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-193 2.6 2 2 Transformers Transformer Standards, Technical Data and Accessories Case Parts for Ventilated Units, continued Frame(s) 1 Front Panel (Upper) Front Panel (Lower) Back Panel (Upper) Back Panel (Lower) Front or Back Panel (Cutout Cover Plate) Top Cover Side Panel (Two Required per Transformer) Bottom 2 Three-Phase 908 7073C37P01 — 7073C37P01 — — 1714C45P01 1714C44P03 7073C20P05 2 909 7073C37P01 — 7073C37P01 — — 1714C45P01 1714C44P03 7073C20P05 2 910 1714C46P01 — 1714C46P01 — — 1714C45P01 1714C44P01 7073C20P01 911 1714C46P01 — 1714C46P01 — — 1714C45P01 1714C44P01 7073C20P01 2 912 1714C46P01 — 1714C46P01 — — 1714C45P01 1714C44P01 7073C20P01 916 1714C60P01 — 1714C60P01 — — 1714C58P01 1714C56P01 7073C20P03 2 917 47-44973-1 — 47-44973-1 — — 1714C67P01 1714C64P01 7073C20P04 918 47-44973-1 — 47-44973-1 — — 1714C67P01 1714C64P01 7073C20P04 2D46331P04 2D46331P03 2D46331P04 2D46331P01 2D46331P02 2D46332P01 2D46331P04 2D46331P01 2 919, 919E, 919EX 2D46331P03 2 920, 920E, 920EX 2D46331P03 2D46331P04 2D46331P03 2D46331P04 922 2D46391H06 2D46391H08 2D46391H03 2D46391H08 2D46331P02 2D46332P01 2D46331P04 2D46391H02 2D46392H01 — 2 923 47-45927-1 — 47-45927-1 — — 47-45926-1 47-45925-1 47-45759-1 910A 47-40592 — 47-40592 — — 1714C45P01 47-40591 47-40589 2 911A 47-40592 — 47-40592 — — 1714C45P01 47-40591 47-40589 912A 47-40592 — 47-40592 — — 1714C45P01 47-40591 47-40589 2 912B 47-49323-1 — 47-49323-1 — — 47-49322-1 47-49321-1 47-49320-1 2 912D 47-55332-2 — 47-55332-2 — — 47-55331-2 47-55329-2 47-55330-1 912DN 47-55332-4 — 47-55332-4 — — 47-55331-2 47-55329-2 47-55330-3 2 913A 1714C47P03 — 1714C47P03 — — 1714C45P02 1714C44P07 7073C30P02 913B 47-40580 — 47-40580 — — 1714C45P02 47-40578 47-41792 2 914A 1714C47P03 — 1714C47P03 — — 1714C45P02 1714C44P07 7073C30P02 2 914B 47-40580 — 47-40580 — — 1714C45P02 47-40578 47-41792 914D 47-49317-1 — 47-49317-1 — — 47-49316-1 47-49315-1 47-49314-1 2 914F/915F 47-56915-1 — 47-56915-1 — — 47-56916-1 47-56917-1 47-56918-1 915A 1714C47P03 — 1714C47P03 — — 1714C45P02 1714C44P07 7073C30P02 2 915B 47-40580 — 47-40580 — — 1714C45P02 47-40578 47-41792 915D 47-49317-1 — 47-49317-1 — — 47-49316-1 47-49315-1 47-49314-1 2 916A 47-41790 — 47-41790 — — 47-41791 47-41789 47-41788 2 918A 47-41801 — 47-41801 — — 47-41802 47-41800 47-41802 912Z 47-49323-1 — 47-49323-1 — — 47-49322-1 47-49991-1 47-49989-1 2 915Z 47-49317-1 — 47-49317-1 — — 47-49316-1 47-49994-1 47-49995-1 916Z 47-49992-1 — 47-49992-1 — — 47-41791 47-49988-1 47-49987-1 2 939 73-5902-1 — 73-5902-1 — — 73-5903-1 73-5900-1 73-5901-1 940 73-5902-2 — 73-5902-2 — — 73-5903-2 73-5900-2 73-5901-2 2 942 73-5902-3 — 73-5902-3 — — 73-5903-3 73-5900-3 73-5901-3 2 943 73-5902-4 — 73-5902-4 — — 73-5903-4 73-5900-4 73-5901-4 944 73-5902-5 — 73-5902-5 — — 73-5903-5 73-5900-5 73-5901-5 945 73-5902-6 — 73-5902-6 — — 73-5903-6 73-5900-6 73-5901-6 2 2 2 Notes 1 Effective June 1, 2001, frame numbers will have a prefix of FR, e.g., FR819. Dimensions, accessories and so on are still applicable as if the FR did not exist. Parts listed are for standard catalog listed transformers. Units with modifications may require different parts. (Frame number from transformer nameplate required.) Transformer nameplate and UL label are not field replaceable. 2 2 2 V2-T2-194 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.6 Transformers Transformer Standards, Technical Data and Accessories Technical Data and Specifications Customer-Furnished Connecting Cables Eaton recommends that external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Primary and secondary terminal lugs are not included. Lug kits are available separately. Overload Capability Short-term overload capacity is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 200% nameplate load for one-half hour, 150% load for one hour and 125% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. Taps Primary taps are available in most ratings to allow compensation for source voltage variations. Series-Multiple Windings Series-multiple windings consist of two similar coils in each winding that can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with a “x” or “/” between the voltage ratings, such as voltages of “120/240” or “240 x 480.” If the series-multiple winding is designated by an “x,” the winding can be connected only for a series or parallel. With the “/” designation, a midpoint also becomes available in addition to the series or parallel connection. As an example, a 120 x 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), 240 (series) or 240 with a 120 midpoint. Enclosures Eaton’s ventilated transformers—Types DS-3, DT-3, MD and KT—use a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Eaton encapsulated—Types EP, EPT, EPZ and EPTZ— and totally enclosed, nonventilated (Types DS-3E and DT-3E) transformers use a NEMA 3R rated enclosure. Buck-Boost Transformers An autotransformer has only one winding, and is therefore smaller and more economical than the conventional twowinding transformer. In an autotransformer, the primary and secondary are electrically and mechanically connected. The required secondary voltage is obtained by “tapping-off” from the single winding. Buck-boost autotransformers are insulated units with 120 x 240 or 240 x 480 volt primaries and 12/24, 16/32 or 24/48 volt secondaries, and provide a very economical method for minor voltage adjustments where circuit isolation is not needed. Autotransformers can be used only where local electrical codes permit, and isolation of the two circuits is not required. Nonlinear Ratings The transformers shall be specifically designed to supply circuits with a harmonic profile equal to or less than a K-factor of 4 or 13, as described in the following table, without exceeding specified temperature rise. Nonlinear Ratings Harmonic K-4 K-13 Fundamental 100.0% 100.0% 3rd 34.0% 70.0% 5th 22.0% 42.0% 7th 3.0% 5.0% 9th 1.0% 3.0% 11th 0.7% 3.0% 13th 0.5% 1.0% 15th 0.3% 0.7% 17th 0.3% 0.6% transformers and their installation to minimize the potential for sound transmission to surrounding structures and sound reflection. It is suggested that the following installation methods be included: 1. If possible, mount the transformer away from corners of walls or ceilings. For installation that must be near a corner, use soundabsorbing materials on the walls and ceilings if necessary to eliminate reflection. Sound Levels All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher (up to 15 dB greater) due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. 2. Provide a solid foundation for mounting the transformer and then use vibration dampening mounts if not already provided in the transformer. (Eaton encapsulated EP/EPT designs use a special encapsulation system and ventilated DS/DT-3 designs contain a built-in vibration dampening system to minimize and isolate sound transmission.) All Eaton general-purpose dry-type distribution transformers are designed with sound levels lower than NEMA ST-20 maximum levels. However, consideration should be given to the specific location of the 3. Provide flexible conduit to make the connections to the transformer. 4. Locate the transformer as far as possible from areas where high sound levels are undesirable. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Average Sound Levels NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 Encapsulated (up to 1.2 kV) 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 2 2 2 2 50.01 to 75.00 50 53 55 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 500.01 to 700.00 62 65 61 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2 2 2 2 V2-T2-195 2 2.6 2 2 Transformers Transformer Standards, Technical Data and Accessories Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Aluminum Wound 1 Type EP 115°C Rise 2 % Impedance 2 Weight Lbs Losses in Watts Efficiency 2 kVA Al Cu No Load Total 1/4 Load 1/2 Load 3/4 Load Full Load 100% P.F. 80% P.F. Min. Max. Sound Level dB 0.05 — 7 6 9 65.3 79.6 84.3 85.6 5.9 6.4 5.5 9.5 45 2 0.075 — 7 7 14 66.0 79.0 82.5 82.8 9.4 9.2 7.5 11.0 45 0.10 — 7 5 15 82.4 86.9 87.7 86.5 10.3 10.6 8.0 12.0 45 2 0.15 — 8 7 20 83.4 88.2 88.9 87.8 9.0 9.6 8.0 12.0 45 2 0.25 — 12 14 29 79.0 87.2 89.5 89.6 5.9 7.5 7.5 9.5 45 0.5 — 13 20 47 85.1 90.3 91.4 91.4 5.5 7.0 5.0 7.0 45 2 0.75 — 20 29 57 86.0 91.3 92.7 92.9 3.9 5.0 4.0 6.0 45 1 — 30 24 60 90.8 93.9 94.5 94.4 3.8 4.9 3.8 5.8 45 2 1.5 65 40 30 90 92.5 94.7 95.0 94.6 4.1 5.2 2.5 4.5 45 2 113 40 30 100 94.2 95.7 95.8 95.4 3.6 4.7 3.3 5.3 45 2 3 — 69 61 135 92.0 95.0 95.7 95.7 2.5 3.5 2.5 4.1 45 2 5 — 120 104 215 91.8 95.0 95.8 95.9 2.3 3.3 2.0 4.6 45 7.5 123 133 129 250 93.2 96.0 96.7 95.9 1.5 2.4 2.4 3.4 45 10 193 208 153 295 93.9 96.3 97.0 97.2 1.5 2.5 2.0 3.3 50 15 216 235 209 435 94.4 96.6 97.1 97.2 1.6 2.8 1.6 3.6 50 25 385 414 191 440 96.8 98.0 98.3 98.4 1.1 2.5 1.6 4.2 50 37.5 735 856 225 370 97.4 98.3 98.5 98.4 1.2 2.6 2.8 4.0 50 2 2 % Regulation 2 2 Type EPT 115°C Rise 3 % Impedance 2 Weight Lbs Losses in Watts Efficiency kVA Al Cu No Load Total 1/4 Load 1/2 Load 3/4 Load Full Load 100% P.F. 80% P.F. Min. Max. Sound Level dB 3 116 123 110 165 87.3 92.6 94.3 94.9 2.1 6.1 2.4 8.0 45 6 143 153 145 275 90.9 94.5 95.5 95.7 2.2 3.1 2.9 4.9 45 2 9 166 178 195 375 91.6 95.0 95.9 96.1 2.0 2.8 2.0 3.6 45 2 15 275 300 265 545 93.0 95.7 96.5 96.6 1.9 3.1 1.9 3.9 50 30 422 504 250 665 96.5 97.7 98.0 97.9 1.5 2.5 1.8 3.8 50 2 45 660 745 300 740 97.2 98.2 98.4 98.5 1.0 2.1 1.8 4.0 50 75 1275 1450 400 945 97.7 98.6 98.8 98.8 0.8 1.6 1.7 3.4 55 2 Notes 1 Typical values for aluminum windings. Contact Eaton for values of copper windings. Up-to-date design data is available at www.eaton.com. 2 Actual impedance may be ± 7.5%. 3 Type EPT transformers 3–15 kVA are T-T connected. 2 2 2 2 % Regulation Performance data is based upon 480 volt Delta primary and a 208Y/120 volt secondary for three-phase transformers; 240 x 480 volt primary and a 120/240 volt secondary for single-phase transformers. All data is subject to future revision. Refer to Eaton for 5 kV class information. All data is subject to future revision. 2 2 2 2 2 2 2 V2-T2-196 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.6 Transformers Transformer Standards, Technical Data and Accessories Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Aluminum Wound 2 2 Type DS-3 150°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20º) Total at Rise +20 25% 50% 97.7 % Regulation Inrush 75% Full Load 100% PF 80% PF % Imp. Trise +20 X Trise +20 R Trise +20 Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 97.3 96.7 2.0 2.5 3.46 1.9 2.9 45 97.70 910 303 kVA Weight No Load 15 196 80 518 97.5 25 261 110 736 98.2 98.2 97.8 97.3 1.6 2.1 2.97 1.6 2.5 45 98.00 1477 492 38 304 132 1141 98.3 98.1 97.7 97.1 1.8 3.8 4.85 4.0 2.7 45 98.20 1056 352 50 396 145 1699 98.4 98.1 97.5 96.8 2.1 4.2 5.32 4.3 3.1 45 98.30 1078 359 75 688 260 1622 98.4 98.6 98.3 97.9 1.5 2.7 3.46 2.9 1.8 50 98.50 3428 1143 100 699 300 2527 98.5 98.4 98.1 97.6 1.9 4.0 5.17 4.7 2.2 50 98.60 2596 865 167 1610 900 3987 68.7 98.7 98.4 98.0 1.4 6.8 9.70 9.5 1.8 55 98.70 1250 416 Efficiency (Trise +20º) Total at Rise +20 25% 50% % Regulation Inrush 75% Full Load 100% PF 80% PF % Imp. Trise +20 X Trise +20 R Trise +20 Sound Level dB TP1 Efficiency Absolute Max. Practical Max. kVA Weight No Load 15 246 80 519 97.8 97.8 97.3 96.8 2.1 3.1 3.9 2.6 2.9 45 97.70 773 244 25 373 300 766 97.7 98.1 98.0 97.7 1.4 2.8 3.3 2.8 1.9 45 98.00 1102 367 37.5 380 125 1182 98.2 98.4 98.1 97.8 2.0 3.1 4.1 2.9 2.8 45 98.20 616 205 50 590 300 417 98.4 98.3 97.9 97.4 1.8 4.1 5.2 5.2 0.2 45 98.30 1553 511 75 689 170 2356 98.5 98.2 97.6 97.0 2.7 5.6 6.9 6.3 2.9 50 98.50 1717 572 Efficiency (Trise +20º) Total at Rise +20 25% 50% % Regulation Inrush 75% Full Load 100% PF 80% PF % Imp. Trise +20 X Trise +20 R Trise +20 Sound Level dB TP1 Efficiency Absolute Max. Practical Max. kVA Weight No Load 15 360 115 269 97.4 98.3 98.4 98.4 0.8 1.7 2.0 1.8 1.0 45 97.70 1381 460 25 370 120 580 97.8 98.2 98.0 97.8 1.5 3.2 3.9 3.4 1.8 45 98.00 1046 348 37.5 565 150 834 98.1 98.4 98.1 97.8 1.5 3.3 4.1 3.6 1.8 45 98.20 1471 490 50 680 175 1014 98.4 98.5 98.4 98.1 1.5 3.4 4.2 3.9 1.7 45 98.30 1733 577 75 900 260 1387 98.3 98.6 98.5 98.2 1.4 3.5 4.3 4.0 1.5 50 98.50 2423 807 Total at Rise +20 Efficiency (Trise +20º) % Regulation 80% PF X Trise +20 R Trise +20 Weight 15 204 95 778 96.6 96.7 96.0 95.1 4.8 4.0 4.8 1.4 4.6 45 97.00 382 127 30 291 165 1207 97.2 97.3 96.9 96.2 3.7 5.6 4.6 3.0 3.5 45 97.50 479 159 37.5 381 210 1428 97.5 97.5 97.0 96.4 3.5 5.5 4.5 3.1 3.2 45 97.70 484 161 45 351 210 1911 97.5 97.4 96.7 96.0 3.8 6.3 5.1 3.4 3.8 45 97.70 564 188 50 531 270 1316 97.7 98.1 97.9 97.5 2.2 4.0 3.2 2.4 2.1 45 98.00 999 333 75 553 300 2917 97.9 97.7 97.0 96.3 3.6 6.6 5.3 4.0 3.5 50 98.00 561 187 112.5 793 400 3693 98.0 98.0 97.5 96.9 3.2 7.5 6.0 5.2 2.9 50 98.20 1049 350 150 913 490 4923 98.2 98.0 97.5 96.9 3.2 6.5 5.3 4.4 3.0 50 98.30 1518 506 225 1343 650 6476 98.4 98.2 97.8 97.2 2.8 6.3 5.1 4.4 2.6 55 98.50 2204 734 300 1597 750 8239 98.5 98.3 97.9 97.3 2.9 8.9 7.6 7.2 2.5 55 98.60 2097 699 500 2590 1400 9782 98.6 98.7 98.5 98.1 1.9 8.2 7.2 7.0 1.7 60 98.70 3769 1256 750 3340 1800 12,692 98.8 98.9 98.7 98.4 1.8 8.9 8.0 7.9 1.5 64 98.80 4521 1507 75% 100% PF % Imp. Trise +20 kVA 50% Full Load Inrush No Load 25% 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Type DT-3 150°C Rise NEMA TP-1 Efficient Losses in Watts 2 2 Type DS-3 80°C Rise NEMA TP-1 Efficient Losses in Watts 2 2 Type DS-3 115°C Rise NEMA TP-1 Efficient Losses in Watts 2 Sound Level dB TP1 Efficiency Absolute Max. Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Practical Max. V2-T2-197 2 2 2 2 2 2 2 2 2 2.6 2 2 Transformers Transformer Standards, Technical Data and Accessories Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Aluminum Wound Type DT-3 115°C Rise NEMA TP-1 Efficient 2 Losses in Watts % Regulation Inrush 15 202 100 743 96.7 96.8 96.2 95.4 4.4 3.9 4.4 1.2 4.3 45 97.00 383 127 2 30 311 165 1492 97.3 97.1 96.3 95.5 4.5 4.8 4.8 1.8 4.4 45 97.50 411 137 2 45 418 220 1458 97.8 97.9 97.5 97.0 2.8 5.4 4.6 3.7 2.8 45 97.70 550 183 50 556 270 1211 97.6 98.1 98.0 97.7 1.9 3.7 3.2 2.6 1.9 45 98.00 892 297 2 75 581 300 2415 97.9 97.9 97.5 96.9 3.0 6.7 5.9 5.1 2.8 50 98.00 758 252 112.5 829 440 3209 98.0 98.1 97.8 97.3 2.6 3.6 3.1 1.9 2.5 50 98.20 1301 433 2 150 996 530 3781 98.1 98.3 97.9 97.5 2.4 5.8 5.2 4.7 2.2 50 98.30 1534 511 225 1569 720 5205 98.4 98.4 98.1 97.8 2.2 6.8 6.2 5.8 2.0 55 98.50 1875 631 2 300 1908 830 6926 98.5 98.5 98.2 97.8 2.3 6.0 5.4 4.9 2.0 55 98.60 2678 872 2 500 3117 1650 6968 98.5 98.9 98.8 98.7 1.2 6.6 6.6 6.5 1.1 60 98.70 3930 1310 750 4884 2000 9335 98.9 99.1 99.0 98.8 1.3 8.7 9.0 8.9 1.0 64 98.80 4458 1486 2 75% 80% PF R Trise +20 2 50% 100% PF X Trise +20 Weight 25% Full Load % Imp. Trise +20 kVA 2 Total at Rise +20 Efficiency (Trise +20º) No Load Sound Level dB TP1 Efficiency Absolute Max. Practical Max. Type DT-3 80°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20º) 50% Inrush 75% 100% PF 80% PF % Imp. Trise +20 X Trise +20 R Trise +20 Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 119 Weight 2 15 276 165 551 96.7 97.4 97.2 96.8 3.4 3.9 3.5 2.3 2.6 45 97.00 358 30 350 180 904 97.3 97.8 97.6 97.2 2.5 3.9 3.4 2.5 2.4 45 97.50 337 112 2 45 540 290 1027 97.7 98.2 98.2 97.9 1.7 3.5 3.3 2.9 1.6 45 97.70 953 317 75 810 360 1782 97.8 98.2 98.0 97.7 0.3 3.5 4.3 3.9 1.9 50 98.00 1006 355 2 112.5 944 470 2521 98.2 98.4 98.2 97.9 1.9 4.4 4.1 3.7 1.8 50 98.20 1554 518 2 150 1438 650 2760 98.2 98.6 98.5 98.3 1.5 4.8 4.7 4.5 1.4 50 98.30 1665 555 225 1746 830 4047 98.3 98.6 98.5 98.3 1.6 5.5 5.6 5.4 1.4 55 98.50 2003 667 300 2400 1100 5338 98.6 99.0 99.0 98.9 1.6 5.9 6.1 5.9 1.4 55 98.60 2655 885 500 3418 1800 5858 98.6 99.0 99.0 98.9 0.9 4.9 5.4 5.3 0.8 60 98.70 4462 1487 % Imp. Trise +20 X Trise +20 R Trise +20 Sound Level dB TP1 Efficiency Absolute Max. 2 25% % Regulation kVA 2 Total at Rise +20 Full Load No Load 2 2 2 Type KT-4 150°C Rise NEMA TP-1 Efficient Losses in Watts % Regulation Weight 2 15 206 100 883 96.7 96.5 95.6 94.6 5.5 5.2 5.5 1.8 5.2 45 97.00 375 125 30 311 165 1263 97.2 97.3 96.7 96.0 3.9 7.4 6.0 4.8 3.7 45 97.50 453 151 2 45 400 220 1554 97.7 97.7 97.3 96.7 3.2 5.9 4.8 3.8 3.0 45 97.70 710 236 2 75 547 300 2622 97.9 97.8 97.2 96.6 3.3 6.7 5.3 4.4 3.1 50 98.00 995 331 112.5 800 440 3525 98.0 98.0 97.6 97.0 3.0 7.4 6.0 5.3 2.7 50 98.20 1082 360 2 150 1010 530 4055 98.1 98.2 97.8 97.4 2.6 6.6 5.4 4.8 2.3 50 98.30 1574 524 225 1680 700 5879 98.3 98.3 97.9 97.5 2.6 7.6 6.3 5.9 2.3 55 98.50 1943 647 2 300 2122 1100 5895 98.4 98.6 98.4 98.1 1.9 6.8 5.9 5.7 1.6 55 98.60 2863 954 500 3201 1800 7054 98.5 98.9 98.8 98.7 1.3 5.9 5.4 5.2 1.1 60 98.70 4588 1529 25% 50% 75% Full Load 100% PF 80% PF Inrush kVA 2 Total at Rise +20 Efficiency (Trise +20º) No Load 2 2 2 V2-T2-198 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Practical Max. 2.6 Transformers Transformer Standards, Technical Data and Accessories Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Aluminum Wound 2 2 Type KT-4 115°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20º) Total at Rise +20 25% 50% % Regulation Inrush 75% Full Load 100% PF 80% PF % Imp. Trise +20 X Trise +20 R Trise +20 Sound Level dB TP1 Efficiency Absolute Max. Practical Max. kVA Weight No Load 15 307 135 394 96.3 97.5 97.6 97.5 1.8 2.7 2.2 1.4 1.7 45 97.00 491 163 30 313 165 1344 97.4 97.3 96.6 95.9 4.1 5.1 4.6 2.4 3.9 45 97.50 584 194 45 400 220 1463 97.8 97.9 97.5 97.0 3.0 6.1 5.2 4.4 2.8 45 97.70 591 197 75 587 285 2355 97.9 97.9 97.5 97.0 2.9 6.7 5.9 5.2 2.8 50 98.00 823 274 112.5 947 470 2910 97.9 98.1 97.9 97.5 2.4 5.0 4.3 3.7 2.2 50 98.20 1447 482 150 1243 560 4119 98.1 98.2 97.8 97.4 2.5 6.6 5.7 5.2 2.4 50 98.30 1468 489 225 1680 700 5413 98.3 98.3 98.1 97.7 2.3 7.5 7.0 6.7 2.1 55 98.50 1719 573 300 2480 1100 5735 98.4 98.7 98.5 98.2 1.8 6.7 6.3 6.1 1.5 55 98.60 2547 849 2 2 2 2 2 2 2 2 Type KT-4 80°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20º) % Regulation Inrush kVA Weight No Load Total at Rise +20 25% 50% 75% Full Load 100% PF 80% PF % Imp. Trise +20 15 378 165 416 96.4 97.6 97.7 97.6 1.7 2.9 2.5 1.9 1.7 45 97.00 482 160 30 365 188 877 97.2 97.7 97.6 97.2 2.4 3.9 3.5 2.6 2.3 45 97.50 583 194 45 550 285 1055 97.4 98.1 98.0 97.8 1.8 3.7 3.4 2.9 1.7 45 97.70 708 236 75 774 360 1784 97.8 98.2 98.0 97.7 2.0 4.7 4.5 4.0 1.9 50 98.00 986 328 X Trise +20 R Trise +20 Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 2 2 112.5 1380 550 1872 97.9 98.5 98.5 98.4 1.3 4.2 4.2 4.1 1.2 50 98.20 1577 525 150 1604 700 2728 98.0 98.5 98.5 98.3 1.4 4.4 4.5 4.3 1.4 50 98.30 1880 626 225 2336 850 3728 98.4 98.7 98.6 98.4 1.4 5.0 5.2 5.1 1.3 55 98.50 2647 882 300 2689 1100 4589 98.4 98.8 98.7 98.5 1.4 5.5 5.8 5.6 1.2 55 98.60 2610 870 Efficiency (Trise +20º) Total at Rise +20 25% 50% 96.7 97.3 2 2 2 2 Type KT-13 150°C Rise NEMA TP-1 Efficient Losses in Watts 2 % Regulation Inrush 75% Full Load 100% PF 80% PF % Imp. Trise +20 X Trise +20 R Trise +20 Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 97.0 96.5 3.1 4.2 3.6 2.1 2.9 45 97.00 379 126 kVA Weight No Load 15 271 165 604 30 365 198 977 97.1 97.6 97.3 96.9 2.7 4.3 3.5 2.4 2.6 45 97.50 565 188 45 545 280 1215 97.5 98.0 97.8 97.4 2.2 4.2 3.3 2.6 2.1 45 97.70 890 277 75 812 360 2139 97.7 98.0 97.8 97.4 2.6 5.9 4.9 4.3 2.4 50 98.00 907 302 112.5 920 490 3059 98.0 98.2 97.8 97.4 2.4 5.0 4.1 3.4 2.3 50 98.20 1513 504 150 1221 530 4297 98.1 98.1 97.7 97.2 2.7 6.5 5.3 4.6 2.5 50 98.30 1790 597 225 1960 830 4461 98.3 98.6 98.3 98.0 1.9 6.6 6.1 5.9 1.6 55 98.50 1771 590 300 2358 1100 5931 98.4 98.6 98.4 98.2 1.9 7.2 6.3 6.0 1.6 55 98.60 2543 847 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-199 2.6 2 2 Transformers Transformer Standards, Technical Data and Accessories Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Aluminum Wound Type KT-13 115°C Rise NEMA TP-1 Efficient 2 Losses in Watts Efficiency (Trise +20º) Total at Rise +20 25% 50% % Regulation Inrush 75% Full Load 100% PF 80% PF % Imp. Trise +20 X Trise +20 R Trise +20 Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 2 kVA Weight No Load 15 332 165 432 96.6 97.6 97.6 97.4 1.9 3.2 2.8 2.2 1.8 45 97.00 409 136 2 30 390 200 903 97.3 97.8 97.6 97.2 2.5 4.4 3.6 2.8 2.3 45 97.50 420 120 2 45 548 280 1187 97.5 98.1 98.0 97.7 2.2 — 3.0 2.3 2.0 45 97.70 836 278 75 808 360 1850 97.8 98.1 97.8 97.5 2.4 5.6 4.8 4.3 2.2 50 98.00 805 268 2 112.5 990 540 2373 97.9 98.3 98.2 98.0 1.8 4.5 4.0 3.6 1.6 50 98.20 1303 434 150 1600 650 2372 98.1 98.5 98.4 98.1 1.3 3.4 3.0 2.8 1.1 50 98.30 1932 644 2 225 2306 850 4001 98.3 98.7 98.6 98.3 1.6 4.9 5.1 4.9 1.4 55 98.50 2508 836 300 3291 1100 4583 98.4 98.8 98.7 98.5 1.3 6.2 6.3 6.2 1.2 55 98.60 2851 950 2 2 2 Type KT-13 80°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20º) 25% 50% % Regulation Inrush 75% 100% PF 80% PF % Imp. Trise +20 X Trise +20 R Trise +20 Sound Level dB TP1 Efficiency Absolute Max. Practical Max. kVA Weight 2 15 315 165 536 96.4 97.3 97.2 96.9 2.5 3.9 3.6 2.5 2.5 45 97.00 375 125 2 30 408 188 854 97.4 97.9 97.7 97.3 2.3 4.0 3.6 2.8 2.2 45 97.50 497 166 45 555 280 982 97.6 98.2 98.2 98.0 1.6 3.2 3.0 2.5 1.6 45 97.70 656 218 2 75 838 400 1289 97.8 98.4 98.5 98.4 1.3 3.0 2.9 2.6 1.2 50 98.00 1624 541 112.5 1367 550 1905 97.9 98.5 98.5 98.4 1.3 4.2 4.4 4.2 1.2 50 98.20 1171 390 2 150 1607 668 2474 98.2 98.6 98.6 98.4 1.4 4.6 4.7 4.5 1.2 50 98.30 1562 520 225 2582 850 3471 98.3 98.7 98.7 98.5 1.3 5.1 6.3 6.2 1.2 55 98.50 2159 719 300 3228 1100 3978 98.3 98.8 98.8 98.7 1.1 4.2 4.5 4.3 1.0 55 98.60 3255 1085 2 Total at Rise +20 Full Load No Load 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-200 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.6 Transformers Transformer Standards, Technical Data and Accessories Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Copper Wound 2 2 Type DS-3 150°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20°) % Regulation Inrush kVA Weight No Load Total at Rise +20 25% 50% 75% Full Load 100% PF 80% PF % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 15 270 80 605 97.6 97.5 96.9 96.3 3.5 4.2 4.2 2.3 3.5 45 97.70 551 183 25 406 115 732 97.9 98.1 97.7 97.3 — — 3.5 2.5 2.5 45 98.00 1379 459 37.5 453 125 1154 98.2 98.1 97.6 97.0 2.7 3.7 4.8 4.0 2.7 45 98.20 1321 440 50 657 160 1159 98.3 98.4 98.1 97.7 2.0 3.3 3.8 3.8 2.0 45 98.30 1321 440 75 803 175 2259 98.5 98.3 97.7 97.1 2.8 4.8 6.5 5.8 2.8 50 98.50 2133 711 100 960 250 2504 98.6 98.4 98.0 97.5 2.3 4.3 5.5 5.0 2.3 50 98.60 2779 926 167 1665 570 3094 98.7 98.8 98.6 98.3 1.5 6.3 9.0 8.8 1.5 50 98.70 2865 955 Efficiency (Trise +20°) % Regulation Inrush 75% Full Load 100% PF 80% PF % Imp. X 98.1 97.8 97.3 2.4 2.2 3.3 Total at Rise +20 25% 50% 2 2 2 2 2 2 Type DS-3 115°C Rise NEMA TP-1 Efficient Losses in Watts 2 R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 2.2 2.4 45 97.70 718 239 kVA Weight No Load 15 264 80 437 97.8 25 420 110 603 97.9 98.2 98.0 97.7 2.0 2.9 3.2 2.6 2.0 45 98.00 862 287 37.5 450 125 1217 98.2 98.0 97.5 96.9 2.9 4.5 5.9 5.1 2.9 45 98.20 1300 433 50 703 300 1409 98.4 98.4 98.0 97.6 2.2 3.8 4.7 4.1 2.2 — 98.30 1498 499 75 793 175 2178 98.5 98.3 97.8 97.2 2.7 4.7 6.2 5.6 2.7 50 98.50 2107 702 2 2 2 2 2 2 Type DS-3 80°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20°) % Regulation Inrush kVA Weight No Load Total at Rise +20 25% 50% 75% Full Load 100% PF 80% PF % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 15 407 115 293 97.3 98.2 98.3 98.2 1.2 1.7 1.8 1.4 1.2 45 97.70 375 125 25 430 300 679 97.9 98.4 98.3 98.1 1.5 2.6 3.0 2.6 1.5 45 98.00 494 164 37.5 685 300 729 98.1 98.6 98.6 98.5 1.1 2.2 2.6 2.3 1.1 45 98.20 617 205 50 799 180 1013 98.3 98.6 98.4 98.1 1.7 2.9 3.4 2.9 1.7 45 98.30 989 329 75 1042 250 1447 98.3 98.6 98.4 98.1 1.6 3.4 3.8 3.5 1.6 50 98.50 1015 338 2 2 2 2 2 2 Type DT-3 150°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20°) Inrush % Regulation kVA Weight No Load Total at Rise +20 25% 50% 75% Full Load 100% PF 80% PF % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 15 250 150 755 98.9 97.0 96.4 95.7 4.2 5.3 4.8 2.6 4.0 45 97.00 321 107 30 350 165 1100 97.3 97.5 97.0 96.5 3.2 4.5 5.2 4.1 3.1 45 97.50 614 204 37.5 415 210 1382 97.5 97.6 97.1 96.5 3.2 4.8 4.0 2.5 3.1 45 97.70 639 213 45 416 215 1786 97.4 97.4 96.9 96.2 3.6 5.5 4.6 3.0 3.5 45 97.70 637 212 50 647 270 1220 97.7 98.2 98.0 97.7 2.0 3.5 2.8 2.0 1.9 45 98.00 1072 357 75 643 320 2903 97.9 97.5 97.1 96.4 3.6 7.4 4.3 2.5 3.4 50 98.00 1015 338 112.5 876 420 3699 97.9 97.9 97.4 96.8 3.0 6.7 5.1 4.2 2.9 50 98.20 1185 395 150 1064 530 4269 98.1 98.2 97.8 97.3 2.7 5.3 4.3 3.5 2.5 50 98.30 1752 584 225 1569 560 7124 98.4 98.1 97.5 97.0 3.2 8.7 7.4 6.8 2.9 55 98.50 2498 832 300 2050 730 7959 98.4 98.3 97.9 97.4 2.6 6.7 5.5 4.9 2.4 55 98.60 2872 964 500 3681 1400 8292 98.8 98.9 98.7 98.4 1.6 7.4 6.8 6.7 1.4 60 98.70 3839 1279 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-201 2.6 2 2 Transformers Transformer Standards, Technical Data and Accessories Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Copper Wound Type DT-3 115°C Rise NEMA TP-1 Efficient 2 Losses in Watts % Regulation Weight 15 256 95 669 97.7 97.8 97.3 96.7 4.0 5.4 4.8 2.9 3.8 45 97.00 229 76 2 30 337 180 1077 97.7 97.8 97.3 96.8 3.0 6.2 4.6 3.5 3.0 45 97.50 433 144 2 45 446 215 1625 97.7 97.7 97.2 96.6 3.2 5.2 4.4 3.1 3.1 45 97.70 658 219 50 630 270 1213 97.8 98.2 98.0 97.7 2.0 3.5 3.0 2.3 1.9 45 98.00 960 320 2 75 662 320 2346 97.9 98.0 97.6 97.0 2.8 5.4 4.7 3.9 2.7 50 98.00 842 280 112.5 914 400 2953 98.1 98.2 97.9 97.4 2.5 5.7 5.0 4.5 2.3 50 98.20 1036 345 2 150 1132 530 3364 98.3 98.5 98.2 97.8 2.0 4.8 4.4 4.0 1.9 50 98.30 1605 535 225 2036 650 6445 98.4 98.3 97.8 97.3 2.9 8.8 8.1 7.7 2.6 55 98.50 1572 524 300 2325 830 6038 98.6 98.7 98.4 98.1 2.0 5.7 5.2 4.9 1.7 55 98.60 1860 620 500 3681 1400 7841 98.8 98.9 98.7 98.5 1.4 6.8 6.8 6.6 1.3 60 98.70 4033 1344 TP1 Efficiency Absolute Max. Practical Max. 150 2 2 2 2 25% 50% 75% Full Load 100% PF 80% PF Inrush kVA 2 Total at Rise +20 Efficiency (Trise +20°) No Load % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. Type DT-3 80°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20°) 75% 80% PF % Imp. X R Sound Level dB 15 349 135 390 96.6 97.7 97.7 97.6 1.8 2.4 2.1 1.3 1.7 45 97.00 449 2 30 410 210 823 97.3 97.9 97.7 97.4 2.1 3.4 3.0 2.1 2.0 45 97.50 493 164 45 504 200 1308 97.9 98.0 97.7 97.2 2.5 4.5 3.9 3.1 2.5 45 97.70 473 158 2 75 818 370 1837 97.9 98.2 98.0 97.7 2.0 9.3 4.3 3.8 2.0 50 98.00 937 312 112.5 1065 440 2409 98.1 98.3 98.0 97.6 1.8 3.8 3.3 2.8 1.8 50 98.20 1754 584 2 150 1410 650 3349 98.3 98.5 98.3 97.9 1.9 3.9 3.7 3.2 1.8 50 98.30 1593 531 2 225 2030 830 4096 98.4 98.7 98.5 98.3 1.6 5.4 5.4 5.2 1.5 55 98.50 2568 856 300 3041 1100 4646 98.5 98.8 98.7 98.5 1.4 5.6 6.1 6.0 1.2 55 98.60 3753 1251 R Sound Level dB TP1 Efficiency Absolute Max. 2 50% Inrush 100% PF Weight 2 25% % Regulation kVA 2 Total at Rise +20 Full Load No Load Type KT-4 80°C Rise NEMA TP-1 Efficient Losses in Watts % Regulation 2 15 251 100 635 96.8 97.1 96.6 96.0 3.7 5.0 4.2 2.1 3.6 45 97.00 265 88 30 326 165 1134 97.4 97.5 97.1 96.5 3.5 5.3 4.3 2.9 3.2 45 97.50 504 168 2 45 479 220 1505 97.6 97.8 97.3 96.8 3.0 5.6 5.0 4.1 2.9 45 97.70 670 223 75 463 300 2883 97.9 97.7 97.1 96.4 3.6 7.1 5.9 4.7 3.4 50 98.00 975 325 2 112.5 977 440 2952 98.1 98.2 97.9 97.5 2.6 6.6 5.6 5.1 2.2 50 98.20 1031 344 2 150 1212 540 3716 98.3 98.4 98.0 97.6 2.4 6.0 5.1 4.6 2.1 50 98.30 1574 524 225 1815 650 5420 98.4 98.5 98.1 97.7 2.4 7.6 6.5 6.2 2.1 55 98.50 1694 565 2 300 2400 830 6259 98.6 98.6 98.4 98.0 2.2 6.3 5.2 4.9 1.8 55 98.60 2594 864 50% 75% 100% PF 80% PF Inrush Weight 25% Full Load % Imp. kVA 2 Total at Rise +20 Efficiency (Trise +20°) No Load X 2 2 2 2 2 V2-T2-202 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Practical Max. 2.6 Transformers Transformer Standards, Technical Data and Accessories Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Copper Wound 2 2 Type KT-4 115°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20°) % Regulation Inrush kVA Weight No Load Total at Rise +20 25% 50% 75% Full Load 100% PF 80% PF % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 15 256 95 702 96.7 96.9 96.3 95.6 4.2 5.7 5.0 2.9 4.0 45 97.00 279 93 30 341 165 1007 97.4 97.6 97.3 96.8 3.0 4.8 4.2 3.1 2.8 45 97.50 466 155 45 526 220 1200 97.9 98.1 97.9 97.5 2.3 5.0 4.1 3.5 2.2 50 97.70 633 211 75 759 300 1715 98.1 98.3 98.1 97.8 1.9 5.0 4.5 4.1 1.9 50 98.00 929 309 112.5 1030 470 2735 98.0 98.3 98.0 97.7 2.2 4.4 3.8 3.2 2.0 50 98.20 1171 390 150 1631 650 3076 98.2 98.5 98.3 98.1 1.7 4.9 4.5 4.2 1.6 50 98.30 1250 416 225 1965 690 4434 98.5 98.6 98.4 98.1 1.9 5.6 5.3 5.0 1.7 55 98.50 1979 659 300 2337 830 6127 98.6 98.7 98.4 98.0 2.0 5.2 4.7 4.3 1.8 55 98.60 2187 729 2 2 2 2 2 2 2 2 Type KT-4 80°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20°) % Regulation Inrush kVA Weight No Load Total at Rise +20 25% 50% 75% Full Load 100% PF 80% PF % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 2 15 365 165 371 97.0 98.0 98.1 98.0 1.5 2.3 2.1 1.5 1.4 45 97.00 499 166 30 424 210 787 97.3 97.9 97.8 97.6 2.0 3.2 2.9 2.2 1.9 45 97.50 659 219 2 45 653 290 977 97.4 98.1 98.1 98.0 1.6 3.1 3.0 2.5 1.5 45 97.70 925 308 75 640 350 1951 97.8 98.1 97.8 97.5 2.2 5.2 4.9 4.4 2.1 50 98.00 854 284 112.5 1264 560 2009 98.2 98.7 98.6 98.4 1.4 4.3 4.2 4.0 1.3 50 98.20 1449 483 150 1825 650 2873 98.5 98.7 98.5 98.2 1.6 6.1 6.4 6.3 1.5 50 98.30 1288 429 225 2096 890 4449 98.3 98.6 98.4 98.1 1.8 6.5 6.6 6.4 1.6 55 98.50 2292 764 2 2 2 2 2 Type KT-13 150°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20°) % Regulation Inrush kVA Weight No Load Total at Rise +20 25% 50% 75% Full Load 100% PF 80% PF % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 2 15 346 165 461 96.2 97.4 97.5 97.3 2.1 3.0 2.5 1.6 2.0 45 97.00 527 176 30 390 190 908 97.2 97.7 97.5 97.1 2.6 4.0 3.3 2.3 2.4 45 97.50 579 193 2 45 623 235 1328 97.6 97.9 97.6 97.2 2.5 3.2 2.8 1.4 2.4 45 97.70 854 285 75 848 370 2402 97.7 97.9 97.5 97.0 2.8 5.7 4.5 3.6 2.7 50 98.00 1046 348 112.5 1080 455 2991 98.0 98.2 97.9 97.4 2.4 4.3 3.5 2.7 2.3 50 98.20 1180 393 150 1431 600 3686 98.2 98.3 98.1 97.7 2.3 5.1 4.2 3.7 2.1 50 98.30 1250 416 225 2129 830 4250 98.4 98.6 98.4 98.2 2.0 6.3 5.4 5.1 1.5 55 98.50 2771 923 2 2 2 2 2 Type KT-13 115°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20°) % Regulation Inrush kVA Weight No Load Total at Rise +20 25% 50% 75% Full Load 100% PF 80% PF % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 2 15 341 165 378 96.6 97.8 97.9 97.9 1.5 2.4 2.1 1.6 1.4 45 97.00 472 157 30 444 188 824 97.1 97.8 97.6 97.3 2.2 3.6 3.1 2.2 2.1 45 97.50 620 206 2 45 598 250 1476 97.4 97.7 97.4 96.9 2.8 4.6 4.0 2.9 2.7 45 97.70 939 313 75 894 350 2128 97.9 98.1 97.9 97.5 1.9 5.1 4.6 4.0 2.4 50 98.00 847 282 112.5 1054 460 2612 98.1 98.3 98.1 97.8 2.0 4.3 3.3 2.6 1.9 50 98.20 1375 458 150 1399 600 3185 98.2 98.5 98.3 98.0 2.0 5.9 5.4 5.1 1.7 50 98.30 1379 460 225 2088 890 4382 98.3 98.6 98.4 98.2 1.8 6.1 5.7 5.5 1.6 55 98.50 2490 830 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-203 2 2 2 2 2.6 2 2 Transformers Transformer Standards, Technical Data and Accessories Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Copper Wound Type KT-13 80°C Rise NEMA TP-1 Efficient 2 Losses in Watts Efficiency (Trise +20°) Weight 15 370 165 382 96.7 97.8 97.9 97.8 1.5 2.4 2.2 1.6 1.4 45 97.00 472 2 30 490 188 595 97.4 98.2 98.2 98.1 1.4 3.0 2.8 2.5 1.4 45 97.50 592 197 2 45 635 290 1189 97.4 97.9 97.8 97.5 2.1 3.9 3.5 2.8 2.0 45 97.70 736 245 75 987 410 1351 97.7 98.9 98.4 98.3 1.4 2.8 2.6 2.3 1.3 50 98.00 1590 530 2 112.5 854 560 2039 98.1 98.6 98.5 98.3 1.4 4.2 4.3 4.1 1.3 50 98.20 1374 458 150 1807 650 3053 98.0 98.4 98.3 98.0 1.7 4.3 4.0 3.7 1.6 50 98.30 1472 490 2 225 4091 1200 2364 98.2 98.9 99.1 99.1 0.6 2.7 2.9 2.8 0.5 55 98.50 4321 1440 R Sound Level dB TP1 Efficiency Absolute Max. 2 25% 50% Inrush kVA 2 Total at Rise +20 % Regulation No Load 75% Full Load 100% PF 80% PF % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 157 Type KT-13 115°C Rise E3 Efficient 2 Losses in Watts No Load Total at Rise +20 Efficiency (Trise +20°) % Regulation Full Load 100% PF 80% PF Inrush % Imp. Practical Max. kVA Weight 15 3.25 78 359 97.6 98.1 98.0 97.7 2.0 3.7 3.2 2.6 1.9 45 98.00 307 102 2 30 370 125 636 98.1 98.4 98.3 98.0 1.7 2.7 2.3 1.6 1.7 45 98.30 779 260 2 45 635 135 1076 98.5 98.5 98.1 97.7 2.2 4.1 3.5 2.8 2.1 45 98.50 617 206 75 870 225 1529 98.5 98.6 98.4 98.0 1.9 4.9 4.4 4.1 1.7 50 98.60 993 331 2 112.5 1526 350 1768 98.6 98.8 98.7 98.5 1.3 3.5 3.1 2.8 1.3 50 98.80 2447 816 150 1665 350 2419 97.8 98.9 98.7 98.4 1.5 4.5 4.2 3.9 1.4 50 98.90 1976 659 2 225 2094 650 3650 98.9 98.9 98.8 98.5 1.5 5.4 5.2 5.1 1.3 55 99.00 2686 895 300 3900 750 3731 98.9 99.1 99.0 98.8 1.3 5.2 5.2 5.1 1.0 55 99.04 2990 997 R Sound Level dB TP1 Efficiency Absolute Max. 2 25% 50% 75% X 2 2 Type KT-9 115°C Rise E3 Efficient 2 Losses in Watts Total at Rise +20 Efficiency (Trise +20°) Inrush % Regulation kVA Weight No Load 2 15 335 78 353 97.4 98.0 98.0 97.7 2.0 3.7 3.2 2.6 1.8 45 98.00 287 96 2 30 406 125 670 98.0 98.3 98.1 97.8 1.9 2.7 2.4 1.5 1.8 45 98.30 780 260 45 635 135 1075 98.6 98.5 98.2 97.7 2.3 4.1 3.5 2.8 2.1 45 98.50 603 201 2 75 870 210 1551 98.5 98.6 98.3 98.0 1.9 4.0 3.6 3.1 1.8 50 98.60 958 319 112.5 1526 350 1583 98.6 98.9 98.8 98.6 1.2 3.0 2.7 2.5 1.1 50 98.80 2480 827 2 150 1665 350 2463 98.8 98.9 98.7 98.4 1.6 4.5 4.2 4.0 1.4 50 98.90 1930 643 225 2094 650 3766 98.8 98.9 98.7 98.4 1.7 5.5 5.2 5.0 1.4 55 99.00 2778 926 25% 50% 75% Full Load 100% PF 80% PF % Imp. X 2 2 2 2 2 2 2 2 V2-T2-204 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Practical Max. 2.6 Transformers Transformer Standards, Technical Data and Accessories Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Copper Wound 2 2 Type NON HMT 115°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20°) % Regulation Inrush kVA Weight No Load Total at Rise +20 25% 50% 75% Full Load 100% PF 80% PF % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 15 362 80 527 97.6 97.7 97.3 96.7 3.2 5.9 5.1 4.2 3.0 45 97.00 — — 30 430 100 1040 98.3 98.0 97.4 96.7 3.2 6.2 5.4 4.4 3.1 45 97.50 — — 45 627 170 1368 98.3 98.2 97.7 97.2 2.8 6.0 5.2 4.4 2.7 45 97.70 — — 75 926 250 2096 98.4 98.3 97.9 97.4 2.6 7.0 6.2 5.7 2.5 50 98.00 — — 112.5 1628 400 2515 98.4 98.5 98.3 97.9 2.0 5.5 4.9 4.5 1.9 50 98.20 — — 150 2001 500 2688 98.5 98.7 98.6 98.3 1.6 5.6 5.2 5.0 1.5 50 98.30 — — 225 3596 590 3310 98.8 98.9 98.8 98.6 1.5 6.2 6.0 5.9 1.2 55 98.50 — — 300 3891 800 4854 98.7 98.9 98.7 98.4 1.7 7.1 7.0 6.8 1.4 55 98.60 — — 2 2 2 2 2 2 2 2 Type THR HMT 115°C Rise NEMA TP-1 Efficient Losses in Watts Efficiency (Trise +20°) % Regulation Inrush kVA Weight No Load Total at Rise +20 25% 50% 75% Full Load 100% PF 80% PF % Imp. X R Sound Level dB TP1 Efficiency Absolute Max. Practical Max. 2 15 — 80 708 97.1 97.0 96.4 95.5 4.3 7.4 6.3 4.7 4.2 45 97.00 — — 30 450 100 1409 98.0 97.4 96.5 95.6 4.7 8.0 6.8 5.2 4.4 45 97.50 — — 2 45 610 170 1374 98.2 98.1 97.7 97.1 2.8 4.8 4.2 3.2 2.7 45 97.70 — — 75 868 250 2341 98.2 98.1 97.6 97.0 2.9 6.6 5.8 5.0 2.8 50 98.00 — — 112.5 1643 400 2685 98.3 98.4 98.1 97.7 2.2 5.5 5.0 4.6 2.0 50 98.20 — — 150 — 500 3304 98.5 98.6 98.3 97.9 2.0 6.7 6.3 6.0 1.9 50 98.30 — — 225 3370 590 3712 98.7 98.8 98.7 98.4 1.7 6.6 6.4 6.2 1.4 55 98.50 — — 300 3894 800 4688 98.9 99.0 98.8 98.5 1.7 7.4 7.2 7.1 1.3 55 98.60 — — 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-205 2.6 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Transformer Standards, Technical Data and Accessories Typical Specifications— General-Purpose (1000 kVA and Below) General Furnish and install, singlephase and three-phase general-purpose individually mounted dry-type transformers of the twowinding type, self-cooled, with ratings and voltages as indicated on the drawings. Transformers shall be manufactured by Eaton. Transformers shall be designed, manufactured and tested in accordance with all the latest applicable ANSI, NEMA and IEEE Standards. All 600-volt class transformers through 1000 kVA shall be UL listed and bear the UL label. Transformers shall be designed for continuous operation at rated kVA, for operation 24 hours a day, 365 days a year, with normal life expectancy as defined in ANSI C57.96. Insulation Systems Transformers shall be insulated as follows: ● 2 2 Transformers ● Type EP or EPT: 0.050 through 75 kVA: 180°C insulation system Type DS-3 or DT-3: 15 kVA and above: 220°C insulation system Required performance shall be obtained without exceeding the above indicated temperature rise in a 40°C maximum ambient, with a 30°C average over 24 hours. Core and Coil Assemblies Transformer core shall be constructed with high-grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Coils shall be wound of electrical-grade [aluminum] [copper] and continuous wound construction. BIL (basic impulse level) for all 600-volt class windings shall be 10 kV. On encapsulated units rated [75 kVA and below] [15 kVA and below] [9 kVA and below], the core and coil assembly shall be completely encapsulated in a proportioned mixture of resin or epoxy and aggregate to provide a moisture-proof, shock-resistant seal. The core and coil encapsulation system shall minimize the sound level. On ventilated units rated [15 kVA and above] [30 kVA and above] [112.5 kVA and above], the core and coil assembly shall be installed on vibrationabsorbing pads. Enclosures The enclosure shall be made of heavy-gauge steel and shall be finished using a continuous process of degreasing, cleaning and phosphatizing, followed by electrostatic deposition of a thermosetting polyester powder coating and subsequent baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. The maximum temperature on top of the enclosure shall not exceed 90°C. suitable weathershields over ventilation openings. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall or structure. Tests The following tests shall be performed as standard on all transformers: 1. Ratio tests at the rated voltage connection and at all tap connections. 2. Polarity and phase relation tests on the rated voltage connection. On units rated [75 kVA and below] [15 kVA and below] [9 kVA and below] encapsulated, the enclosure construction shall be totally enclosed, non-ventilated, NEMA 3R, with lifting provisions. 3. Applied potential tests. 4. Induced potential test. 5. No-load and excitation current at rated voltage on the rated voltage connection. On units rated [15 kVA and above] [30 kVA and above] [112.5 kVA and above], the enclosure construction shall be ventilated, NEMA 2, dripproof, with lifting provisions. All ventilation openings shall be protected against falling dirt. On outdoor units, provide Sound Levels Transformer average sound levels shall not exceed the following ANSI and NEMA levels for self-cooled ratings measured in accordance with NEMA ST-20. Average Sound Levels NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 Encapsulated (up to 1.2 kV) 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 50.01 to 75.00 50 53 55 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 2 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 2 500.01 to 700.00 62 65 61 2 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory 2 2 2 2 2 2 All insulation materials shall be flame-retardant and shall not support combustion as defined in ASTM Standard Test Method D635. 2 2 V2-T2-206 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.6 Transformers Transformer Standards, Technical Data and Accessories Typical Specifications— Dry-Type Transformers for Nonlinear Loads General Furnish and install, individually mounted dry-type transformers of the twowinding type, self-cooled, with ratings and voltages as indicated on the drawings. Transformers shall be manufactured by Eaton. Transformers shall be designed, manufactured and tested in accordance with all the latest applicable ANSI, NEMA and IEEE Standards. All 600-volt class transformers through 500 kVA shall be UL listed as suitable for non-sinusoidal current loads with K factor not to exceed [4] [13] [20]. Insulation Systems Transformers shall be insulated with a UL recognized 220°C insulation system. Winding temperature rise shall be [80°C] [115°C] [150°C]. Required performance shall be obtained without exceeding the above indicated temperature rise in a 40°C maximum ambient, with a 30°C average. All insulation materials shall be flame-retardant and shall not support combustion as defined in ASTM Standard Test Method D635. 2 Core and Coil Assemblies Transformer core shall be constructed with high-grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Enclosures The enclosure shall be made of heavy gauge steel and shall be finished utilizing a continuous process of degreasing, cleaning and phosphatizing, followed by electrostatic deposition of a polymer polyester powder coating and baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. The maximum temperature on top of the enclosure shall not exceed 90°C. Transformer coils shall be wound of electrical-grade [aluminum] [copper] conductor with continuous wound construction. An electrostatic shield consisting of a single turn of aluminum shall be placed between the primary and secondary winding and grounded to the transformer core. BIL (basic impulse level) for all 600-volt class windings shall be 10 kV. The enclosure construction shall be ventilated, NEMA 2, drip-proof, with lifting provisions. All ventilation openings shall be protected against falling dirt. On outdoor units, provide suitable weathershields over ventilation openings. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall or structure. The core and coil assembly shall be installed on vibrationabsorbing pads. Nonlinear Ratings The transformers shall be specifically designed to supply circuits with a harmonic profile equal to or less than a K-factor of 4 or 13 as described below without exceeding [80°C] [115°C] [150°C] temperature rise. The neutral conductor shall be rated to carry 200% of normal phase current. 2 Nonlinear Ratings Harmonic K-4 K-13 Fundamental 100.0% 100.0% 3rd 34.0% 70.0% 5th 22.0% 42.0% 7th 3.0% 5.0% 9th 1.0% 3.0% 11th 0.7% 3.0% 13th 0.5% 1.0% 15th 0.3% 0.7% 17th 0.3% 0.6% Tests The following tests shall be performed as standard on all transformers: 1. Ratio tests at the rated voltage connection and at all tap connections. 2. Polarity and phase relation tests on the rated voltage connection. 3. Applied potential tests. 4. Induced potential test. 5. No-load and excitation current at rated voltage on the rated voltage connection. Sound Levels Transformer average sound levels shall not exceed the following ANSI and NEMA levels for self-cooled ratings measured in accordance with NEMA ST-20. Average Sound Levels 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 Encapsulated (up to 1.2 kV) 2 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 2 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 50.01 to 75.00 50 53 55 2 2 2 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 500.01 to 700.00 62 65 61 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2 2 2 V2-T2-207 2 2.6 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Transformers Transformer Standards, Technical Data and Accessories Typical Specification— AC Adjustable Frequency Drive Isolation Transformers General Furnish and install, singlephase and three-phase general-purpose individually mounted dry-type transformers of the twowinding type, self-cooled, with ratings and voltages for input application as indicated on the drawings. Transformers shall be manufactured by Eaton. Transformers shall be designed, manufactured and tested in accordance with all the latest applicable ANSI, NEMA and IEEE Standards. All 600-volt class transformers through 550 kVA shall be UL listed and bear the UL label. Transformers shall be designed for continuous operation at rated kVA, for operation 24 hours a day, 365 days a year, with normal life expectancy as defined in ANSI C57.96. Insulation Systems Transformers shall be insulated with a UL recognized 220°C insulation system. Required performance shall be obtained without exceeding the above indicated temperature rise in a 40°C maximum ambient, with a 30°C average over 24 hours. All insulation materials shall be flame-retardant and shall not support combustion as defined in ASTM Standard Test Method D635. Core and Coil Assemblies Transformer core shall be constructed with high-grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Coils shall be wound of electrical-grade [aluminum] [copper] and continuous wound construction. BIL (basic impulse level) for all 600-volt class windings shall be 10 kV. A temperature sensing device shall be imbedded in the center coil. The core and coil assembly shall be installed on vibrationabsorbing pads. Enclosures The enclosure shall be made of heavy-gauge steel and shall be finished using a continuous process of degreasing, cleaning, and phosphatizing, followed by electrostatic deposition of a thermosetting polyester powder coating and subsequent baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. The maximum temperature on top of the enclosure shall not exceed 90°C. The following table lists the recommended kVA size of the drive isolation transformer for a specific horsepower requirement. Three-Phase The enclosure construction shall be ventilated, NEMA 2, drip-proof, with lifting provisions. All ventilation openings shall be protected against falling dirt. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall or structure. On outdoor units, provide suitable weathershields over ventilation openings. Sound Levels Transformer average sound levels shall not exceed the following ANSI and NEMA levels for self-cooled ratings measured in accordance with NEMA ST-20. Horsepower AC Motor kVA Minimum 5 7.5 7.5 11 10 14 15 20 20 27 25 34 30 40 40 51 50 63 60 75 75 93 100 118 125 145 150 175 200 220 250 275 300 330 400 440 500 550 600 660 700 770 Average Sound Levels NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 Encapsulated (up to 1.2 kV) 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 9.01 to 15.00 45 45 50 2 15.01 to 30.00 45 45 50 2 30.01 to 50.00 45 48 50 50.01 to 75.00 50 53 55 2 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 2 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 2 300.01 to 500.00 60 63 59 2 500.01 to 700.00 62 65 61 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory 2 V2-T2-208 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.6 Transformers Transformer Standards, Technical Data and Accessories Typical Specifications— Mini–Power Centers (3–30 kVA) General Furnish and install, singlephase and three-phase general-purpose individually mounted mini–power centers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. Mini– power centers shall be manufactured by Eaton. Units shall be designed, manufactured and tested in accordance with all the latest applicable ANSI, NEMA, IEEE, CSA and UL standards, and shall be UL listed and CSA certified and bear the UL and CSA labels. Units shall be designed for continuous operation at rated kVA, 24 hours a day, 365 days a year, with normal life expectancy as defined in ANSI C57.96. Each mini–power center shall include a main primary breaker with an interrupting rating of 14 kA at 277/480 volts; an encapsulated dry-type transformer and a secondary panelboard with main breaker rated 10 kA interrupting rating at 120/240 volts. 2 1. All interconnecting wiring between the primary breaker and transformer, secondary main breaker and transformer, and distribution section shall be factory installed. Main primary, secondary and feeder breakers shall be enclosed with a padlockable hinged door. 2. The secondary distribution section shall accommodate one-inch, plug-in breakers with 10 kA interrupting capacity. 3. On the all-copper, bolt-on designs, the secondary distribution section shall accommodate bolt-on breakers with 10 kA interrupting capacity. Insulation System Transformers shall be insulated with a 180°C insulation system. Required performance shall be obtained without exceeding the above indicated temperature rise in a 40°C maximum ambient, with a 30°C average over 24 hours. All insulation materials shall be flame-retardant and shall not support combustion as defined in ASTM Standard Test Method D635. Core and Coil Assemblies Transformer core shall be constructed with high-grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Coils shall be wound of electrical-grade aluminum (copper) with continuous wound construction. BIL (basic impulse level) for all 600-volt class windings shall be 10 kV. The core and coil assembly shall be completely encapsulated in a proportioned mixture of resin or expoxy and aggregate to provide a moisture-proof, shockresistant seal. The core and coil encapsulation system shall minimize the sound level. Enclosures The enclosure shall be made of heavy-gauge steel and shall be finished using a continuous process of degreasing, cleaning, and phosphatizing, followed by electrostatic deposition of a thermosetting polymer polyester powder coating and subsequent baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. Mini–power centers shall be equipped with a wiring compartment suitable for conduit entry and large enough to allow convenient wiring. The maximum temperature on top of the enclosure shall not exceed 90°C. The core of the transformer shall be grounded to the enclosure. The enclosure shall be totally enclosed, non-ventilated, NEMA 3R, with lifting eyes. Tests The following tests shall be performed as standard on all transformers: 1. Ratio tests at the rated voltage connection and at all tap connections. 2. Polarity and phase relation tests on the rated voltage connection. 3. Applied potential tests. 4. Induced potential test. 5. No-load and excitation current at rated voltage on the rated voltage connection. Sound Levels Transformer average sound levels shall not exceed the following ANSI/NEMA levels for self-cooled ratings measured in accordance with NEMA ST-20. Average Sound Levels 1 kVA NEMA Average Sound Level in dB 0–9 45 10–30 50 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Note 1 Currently being reviewed and revised by NEMA. Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-209 2.6 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Transformers Transformer Standards, Technical Data and Accessories Typical Specification— NEMA TP-1-2002 Compliant Energy-Efficient Transformers General Furnish and install, threephase energy-efficient dry-type transformers that comply with NEMA Standard TP-1-2002 and U.S. DOE 10 CFR Parts 430 and 431. Transformers shall be of the two-winding type, selfcooled, with ratings (kVA) as indicated on the drawings. Transformer’s losses shall conform to NEMA TP-1 requirements. Transformers shall be manufactured by Eaton. Transformers shall be designed, manufactured and tested in accordance with all the latest applicable ANSI, NEMA and IEEE Standards, and shall be listed by Underwriters Laboratories and bear the UL label. Transformers shall be designed for continuous operation at rated kVA, for 24 hours a day, 365 days a year, with normal life expectancy as defined in ANSI C57.96. Insulation System and Temperature Rise Transformers shall be insulated with a 220°C insulation system. Transformers shall be 150°C rise and shall be capable of carrying a 15% continuous overload without exceeding a 150°C rise. Required performance shall be obtained without exceeding the above rise in a 40°C maximum, 30°C average ambient temperature. All insulation materials shall be flame-retardant and shall not support combustion as defined in ASTM Standard Test Method D635. 2 2 2 2 V2-T2-210 Core and Coil Assemblies Transformer core shall be constructed with high-grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Coils shall be wound of electrical grade [aluminum] [copper] and continuous wound construction. BIL (basic impulse level) for all 600-volt class windings shall be 10 kV. The core and coil assembly shall be installed on vibrationabsorbing pads. Enclosures The enclosure shall be made of heavy gauge steel and shall be finished utilizing a continuous process of degreasing, cleaning and phosphatizing, followed by electrostatic deposition of a thermosetting polyester powder coating and subsequent baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. The enclosure construction shall be ventilated, NEMA 2, drip-proof, with lifting provisions. All ventilation openings shall be protected against falling dirt. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall or structure. All transformers shall be equipped with a wiring compartment suitable for conduit entry and large enough to allow convenient wiring. The maximum temperature on top of the enclosure shall not exceed 90°C. Tests The following tests shall be performed as standard on all transformers: 1. Ratio tests at the rated voltage connection and at all tap connections. 2. Polarity and phase relation tests on the rated voltage connection. 3. Applied potential tests. 4. Induced potential test. 5. No-load and excitation current at rated voltage on the rated voltage connection. Efficiency Transformers shall be energy-efficient with minimum efficiencies as set forth per NEMA TP-1-2002 and U.S. DOE 10 CFR Parts 430 and 431 when operated at 35% of full load capacity. NEMA TP-1-2002 Efficiency Levels Tables of Energy Efficiency NEMA Class 1 Efficiency Levels Dry-Type Distribution Transformers—Low Voltage (600 V and below) Single-Phase Three-Phase kVA Efficiency kVA Efficiency 15 97.7 15 97.0 25 98.0 30 97.5 37.5 98.2 45 97.7 50 98.3 75 98.0 75 98.5 112.5 98.2 100 98.6 150 98.3 167 98.7 225 98.5 250 98.8 300 98.6 333 98.9 500 98.7 — — 750 98.8 — — 1000 98.9 Sound Levels Transformer average sound levels shall not exceed the following ANSI and NEMA levels for self-cooled ratings. Average Sound Levels NEMA ST-20 Average Sound Level, dB Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV) kVA Range K-Factor 1, 4, 9 K-Factor 13, 20 Encapsulated (up to 1.2 kV) 3.00 and below 40 40 45 3.01 to 9.00 40 40 45 9.01 to 15.00 45 45 50 15.01 to 30.00 45 45 50 30.01 to 50.00 45 48 50 50.01 to 75.00 50 53 55 75.01 to 112.50 50 53 55 112.51 to 150.00 50 53 55 150.01 to 225.00 55 58 57 225.01 to 300.00 55 58 57 300.01 to 500.00 60 63 59 500.01 to 700.00 62 65 61 700.01 to 1000.00 64 67 63 Greater than 1000 Consult factory Consult factory Consult factory Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Transformer Standards, Technical Data and Accessories 2.6 Glossary of Transformer Terms Air cooled: A transformer that is cooled by the natural circulation of air around, or through, the core and coils. Ambient noise level: The existing or inherent sound level of the area surrounding the transformer, prior to energizing the transformer. Measured in decibels. Ambient temperature: The temperature of the air surrounding the transformer into which the heat of the transformer is dissipated. Ampacity: The currentcarrying capacity of an electrical conductor under stated thermal conditions. Expressed in amperes. Ampere: The practical unit of electric current. Attenuation: A decrease in signal power or voltage. Unit of measure is dB. Autotransformer: A transformer in which part of the winding is common to both the primary and the secondary circuits. Banked: Two or more singlephase transformers wired together to supply a threephase load. Three singlephase transformers can be “banked” together to support a three-phase load. For example, three 10 kVA singlephase transformers “banked” together will have a 30 kVA three-phase capacity. BIL: Basic impulse level. The ability of a transformer’s insulation system to withstand high voltage surges. All Eaton 600V-class transformers have a 10 kV BIL rating. BTU: British thermal unit. In North America, the term “BTU” is used to describe the heat value (energy content) of fuels, and also to describe the power of heating and cooling systems, such as furnaces, stoves, barbecue grills and air conditioners. When used as a unit of power, BTU “per hour” (BTU/h) is understood, though this is often abbreviated to just “BTU.” Buck-boost: The name of a standard, single-phase, two-winding transformer application with the low voltage secondary windings connected as an autotransformer for boosting (increasing) or bucking (decreasing) voltages in small amounts. Applications can either be single-phase or three-phase. CE: Mark to indicate thirdparty approved or selfcertification to specific requirements of the European community. Celsius (centigrade): Metric temperature measure. °F = (1.8 x °C) + 32 °C = (°F-32) / 1.8 Center tap: A tap at the midpoint of a winding. The center tap on three-phase delta-delta transformers is called a lighting tap. It provides 5% of the transformer’s kVA for single-phase loads. Certified tests: Actual values taken during production tests and certified as applying to a given unit shipped on a specific order. Certified tests are serial number–specific. Common mode: Electrical noise or voltage fluctuation that occurs between all of the line leads and the common ground, or between ground and line or neutral. Compensated transformer: A transformer with a turns ratio that provides a higher than nameplate output (secondary) voltage at no load, and nameplate output (secondary) voltage at rated load. It is common for small transformers (2 kVA and less) to be compensated. Conductor losses: Losses (expressed in watts) in a transformer that are incidental to carrying a load: coil resistance, stray loss due to stray fluxes in the windings, core clamps, and the like, as well as circulating currents (if any) in parallel windings. Also called load losses. Continuous rating: The load that a transformer can handle indefinitely without exceeding its specified temperature rise. Core losses: Losses (expressed in watts) caused by magnetization of the core and its resistance to magnetic flux. Also called no-load losses or excitation losses. Core losses are always present when the transformer is energized. CSA: Canadian Standards Association. The Canadian equivalent of Underwriters Laboratories (UL). CSL3: Candidate Standard Level 3 (CSL3) design criteria developed by the U.S. Department of Energy. This term is used when considering the maximum, practical efficiency of a transformer. cUL: Mark to indicate UL Certification to specific CSA Standards. Decibel (dB): Unit of measure used to express the magnitude of a change in signal or sound level. Delta connection: A standard three-phase connection with the ends of each phase winding connected in series to form a closed loop with each phase 120 degrees from the other. Sometimes referred to as three-wire. Dielectric tests: Tests that consist of the application of a voltage higher than the rated voltage for a specified time for the purpose of determining the adequacy against breakdowns of insulating materials and spacings under normal conditions. medium. A transformer that is cooled by a medium other than a liquid, normally by the circulation of air. E3: Eaton’s version of a CSL3 transformer. Eddy currents: The currents that are induced in the body of a conducting mass by the time variation of magnetic flux or varying magnetic field. Efficiency: The ratio of the power output from a transformer to the total power input. Typically expressed as a %. Electrostatic shield: Copper or other conducting sheet placed between primary and secondary windings, and grounded to reduce electrical interference and to provide additional protection from line-to-line or line-to-ground noise. Commonly referred to as “Faraday shield.” Encapsulated transformer: A transformer with its coils either dipped or cast in an epoxy resin or other encapsulating substance. Enclosure: A surrounding case or housing used to protect the contained equipment against external conditions and prevent personnel from accidentally contacting live parts. Environmentally preferable product: A product that has a lesser or reduced negative effect on human health and the environment when compared to competing products that serve the same purpose. This comparison may consider raw materials acquisition, production, manufacturing, packaging, distribution, reuse, operation, maintenance and disposal of the product. This term includes recyclable products, recycled products and reusable products. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Dry-type transformer: A transformer in which the core and coils are in a gaseous or dry compound insulating Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2 2 V2-T2-211 2.6 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Transformers Transformer Standards, Technical Data and Accessories EPACT: The Energy Policy Act of 1992 (EPAct) is an important piece of legislation for efficiency because it established minimum efficiency levels for dry-type distribution transformers manufactured or imported after December 2006. EPAct, which was based on NEMA standards, defined a number of terms, including what constitutes an energyefficient transformer. The DOE issued a rule that defines these transformers and how manufacturers must comply. DOE EPAct rule (PDF): Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures, Labeling, and the Certification Requirements for Electric Motors. Final Rule. 10-CFR Part 431. Excitation current: No load current. The current that flows in any winding used to excite the transformer when all other windings are open-circuited. It is usually expressed in percent of the rated current of a winding in which it is measured. Also called magnetizing current. FCAN: “Full Capacity Above Nominal” taps. Designates the transformer will deliver its rated kVA when connected to a voltage source which is higher than the rated primary voltage. FCBN: “Full Capacity Below Nominal” taps. Designates the transformer will deliver its rated kVA when connected to a voltage source which is lower than the rated primary voltage. Frequency: On AC circuits, designates the number of times that polarity alternates from positive to negative and back again per second, such as 60 cycles per second. Typically measured in Hertz (Hz). Ground: Connecting one side of a circuit to the earth through low resistance or low impedance paths to help prevent transmitting electrical shock to personnel. V2-T2-212 Harmonic: A sinusoidal waveform with a frequency that is an integral multiple of the fundamental frequency (60 Hz). 60 H3 fundamental 120 H3 2nd harmonic 180 H3 3rd harmonic 240 H3 4th harmonic Harmonic distortion: Nonlinear distortion of a system characterized by the appearance of harmonic (non-sinusoidal) currents in the output, when the input is sinusoidal. Harmonic distortion, total (THD): The square root of the sum of the squares of all harmonic currents present in a load, excluding the fundamental 60 Hz current. Usually expressed as a percent of the fundamental. High voltage windings: In a two-winding transformer, the winding intended to have the greater voltage. Usually marked with “H” designations. HMT: Harmonic Mitigating Transformer (HMT) is better able to handle the harmonic currents present in today’s electrical power system. thereby increasing system capacity, reducing distortion throughout a facility, help to minimize downtime and “mysterious” maintenance on equipment, and return the longevity of equipment life through reduced operational energy losses, thereby running cooler. Hp: Horsepower. The energy required to raise 33,000 pounds a distance of one foot in one minute. 1 hp is equal to 746 watts, or 0.746 kW. Hi pot: A standard test on dry-type transformers consisting of extra-high potentials (voltages) connected to the windings. Used to check the integrity of insulation materials and clearances. Hottest-spot temperature: The highest temperature inside the transformer winding. Is greater than the measured average temperature of the coil conductors, when using the resistance change method. Hysteresis: The tendency of a magnetic substance to persist in any state of magnetization. Impedance: The retarding forces of current in an AC circuit; the current-limiting characteristics of a transformer. Symbol = Z Inductance: In electrical circuits, the opposition to a change in the flow of electrical current. Symbol = L Inducted potential test: A standard dielectric test of transformer insulation. Verifies the integrity of insulating materials and electrical clearances. Inrush current: The initial high peak of current that occurs in the first few cycles of energization, which can be 30 to 40 times the rated current. Insulating transformer: Another term for an isolating transformer. Insulation: Material with a high electrical resistance. Insulation materials: Those materials used to insulate the transformer’s electrical windings from each other and ground. Integral TVSS or SPD: Major Standard Change for Surge Protective Devices (formerly known as Transient Voltage Surge Suppressors). The primary safety standard for transient voltage surge suppressors (TVSS) has undergone major revisions in the past three years with mandatory compliance by manufacturers required by September 29, 2009. Even the name of the standard has changed from UL Standard for Safety for Transient Voltage Surge Suppressors, UL 1449 to UL Standard for Safety for Surge Protective Devices, UL 1449. This means that TVSS listed to the UL 1449 2nd Edition standard will no longer be able to be manufactured after Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com September 29, 2009. All Surge Protective Devices must be designed, tested, manufactured and listed to the UL 1449 3rd Edition standard after this date. Isolating transformer: A transformer where the input (primary) windings are not connected to the output (secondary) windings (i.e., electrically isolated). K-factor: A common industry term for the amount of harmonics produced by a given load. The larger the K-factor, the more harmonics that are present. Also used to define a transformer’s ability to withstand the additional heating generated by harmonic currents. kVA: Kilovolt-ampere. Designates the output that a transformer can deliver for a specified time at a rated secondary voltage and rated frequency without exceeding the specified temperature rise. When multiplied by the power factor, will give kilowatts or kW. 1000 VA = 1 kVA Lamination: Thin sheets of electrical steel used to construct the core of a transformer. Limiting temperature: The maximum temperature at which a component or material may be operated continuously with no sacrifice in normal life expectancy. Linear load: A load where the current waveform conforms to that of the applied voltage, or a load where a change in current is directly proportional to a change in applied voltage. Live part: Any component consisting of an electrically conductive material that can be energized under conditions of normal use. Load losses: I2R losses in windings. Also see conductor losses. Transformers Transformer Standards, Technical Data and Accessories Low voltage winding: In a two-winding transformer, the winding intended to have the lesser voltage. Usually marked with “X” designations. Mid-tap: See center tap. Noise level: The relative intensity of sound, measured in decibels (dB). NEMA Standard ST-20 outlines the maximum allowable noise level for dry-type transformers. Nonlinear load: A load where the current waveform does not conform to that of the applied voltage, or where a change in current is not proportional to a change in applied voltage. Non-ventilated transformer: A transformer where the core and coil assembly is mounted inside an enclosure with no openings for ventilation. Also referred to as totally enclosed non-ventilated (TENV). No load losses: Losses in a transformer that is excited at rated voltage and frequency but that is not supplying a load. No load losses include core losses, dielectric losses and conductor losses in the winding due to the exciting current. Also referred to as excitation losses. Overload capability: Shortterm overload capacity is designed into transformers as required by ANSI. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Percent IR (% resistance): Voltage drop due to resistance at rated current in percent of rated voltage. Percent IX (% reactance): Voltage drop due to reactance at rated current in percent of rated voltage. Percent IZ (% impedance): Voltage drop due to impedance at rated current in percent of rated voltage. Phase: Type of AC electrical circuit; usually single-phase two- or three-wire, or threephase three- or four-wire. Polarity test: A standard test on transformers to determine instantaneous direction of the voltages in the primary compared to the secondary. Sound levels: All transformers make some sound mainly due to the vibration generated in its core by alternating flux. All Eaton general-purpose drytype distribution transformers are designed with sound levels lower than NEMA ST-20 maximum levels. Primary taps: Taps added to the primary (input) winding. See Tap. Star connection: Same as a wye connection. Primary voltage: The input circuit voltage. Step-down transformer: A transformer where the input voltage is greater than the output voltage. Power factor: The cosine of the phase angle between a voltage and a current. Ratio test: A standard test of transformers to determine the ratio of the input (primary) voltage to the output (secondary) voltage. Reactance: The effect of inductive and capacitive components of a circuit producing other than unity power factor. Reactor: A single winding device with an air or iron core that produces a specific amount of inductive reactance into a circuit. Normally used to reduce of control current. Regulation: Usually expressed as the percent change in output voltage when the load goes from full load to no load. Scott T connection: Connection for three-phase transformers. Instead of using three sets of coils for a three-phase load, the transformer uses only two sets of coils. Series/multiple winding: A winding consisting of two or more sections that can be connected for series operation or multiple (parallel) operation. Also called seriesparallel winding. Short circuit: A low resistance connection, usually accidental, across part of a circuit, resulting in excessive current flow. Step-up transformer: A transformer where the input voltage is less than the output voltage. T-T connection: See Scott T connection. Tap: A connection brought out of a winding at some point between its extremities, usually to permit changing the voltage or current ratio. Taps are typically used to compensate for above or below rated input voltage, in order to provide the rated output voltage. See FCAN and FCBN. Temperature class: The maximum temperature that the insulation system of a transformer can continuously withstand. The common insulation classes are 105, 150, 180 (also 185) and 220. Temperature rise: The increase over ambient temperature of the windings due to energizing and loading the transformer. Total losses: The sum of the no-load losses and load losses. Totally enclosed nonventilated enclosure: The core and coil assembly is installed inside an enclosure that has no ventilation to cool the transformer. The transformer relies on heat to radiate from the enclosure for cooling. 2.6 Transformer tests: Per NEMA ST-20, routine transformer production tests are performed on each transformer prior to shipment. These tests are: Ratio tests on the rated voltage connection; Polarity and Phase Relation tests on the rated connection; NoLoad and Excitation Current tests at rated voltage on the rated voltage connection and Applied Potential and Induced Potential tests. Special tests include sound level testing. Transverse mode: Electrical noise or voltage disturbance that occurs between phase and neutral, or from spurious signals across metallic hot line and the neutral conductor. Turns ratio: The ratio of the number of turns in the high voltage winding to that in the low voltage winding. Typical test data: Tests that were performed on similar units that were previously manufactured and tested. UL (Underwriters Laboratories): An independent safety testing organization. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Universal taps: A combination of six primary voltage taps consisting of 2 at +2-1/2% FCAN and 4 at -2-1/2% FCBN. Watt: A unit of electrical power when the current in a circuit is one ampere and the voltage is one volt. Wye connection: A standard three-wire transformer connection with similar ends of single-phase coils connected together. The common point forms the electrical neutral point and may be grounded. Also referred to as three-phase four-wire. To obtain the lineto-neutral voltage, divide the line voltage by 3 ( 1.732 ) . 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-213 2.6 Transformers Transformer Standards, Technical Data and Accessories 2 Frequently Asked Questions About Transformers 2 Can 60 Hz transformers be used at other frequencies? Transformers rated for 60 Hz can be applied to circuits with a higher frequency, as long as the nameplate voltages are not exceeded. The higher the frequency that you apply to a 60 Hz transformer, the less voltage regulation you will have. 60 Hz transformers may be used at lower frequencies but only at reduced voltages corresponding to the reduction in frequency. For example, a 480 to 120 volt 60 Hz transformer can carry rated kVA at 50 Hz but ONLY when applied as a 400 to 100 volt transformer (50/60 x 480 = 400). 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Can single-phase transformers be used on a three-phase source? Yes. Any single-phase transformer can be used on a three-phase source by connecting the primary terminals of the single-phase transformer to any two wires of a three-phase system. It does not matter whether the three-phase source is threephase three-wire or threephase four-wire. The output of the transformer will be single-phase. Can transformers be used to create three-phase power from a single-phase system? No. Single-phase transformers alone cannot be used to create the phaseshifts required for a threephase system. Phase shifting devices (reactors or capacitors) or phase converters in conjunction with transformers are required to change singlephase power to three-phase. What considerations need to be taken into account when operating transformers at high altitudes? At altitudes greater than 3300 feet (1000 meters), the density of the air is less than at lower elevations. This reduces the ability of the air surrounding a transformer to cool it, so the temperature V2-T2-214 rise of the transformer is increased. Therefore, when a transformer is being installed at altitudes greater than 3300 feet above sea level, it is necessary to derate the usable capacity of the transformer. The table below lists the derating factors. As an example, a 75 kVA 480V–208Y/120V transformer installed at 10,000 feet needs to be derated by 4%. Instead of 208A output, the usable current is only 199A. Altitude Feet Meters Current Rating Factor 3300 1000 1.00 4000 1200 0.995 5000 1500 0.99 6000 1800 0.985 7000 2100 0.98 8000 2400 0.97 9000 2700 0.965 10,000 3000 0.96 12,000 3600 0.95 14,000 4200 0.935 15,000 4500 0.93 What considerations need to be taken into account when operating transformers where the ambient temperature is high? Eaton’s dry-type transformers are designed in accordance with ANSI standards to operate in areas where the average maximum ambient temperature is 40°C. For operation in ambient temperatures above 40°C, there are two options: 1. Order a custom designed transformer made for the specific application. 2. Derate the nameplate kVA of a standard transformer by 8% for each 10°C of ambient above 40°C. What is the normal life expectancy of a transformer? When a transformer is operated under ANSI/IEEE basic loading conditions ANSI C57.96), its normal life expectancy is 20 years. The ANSI/IEEE basic loading conditions are: A. The transformer is continuously loaded at rated kVA and rated voltages. B. The average temperature of the ambient air during any 24-hour period is equal to 30°C and at no time exceeds 40°C. C. The altitude where the transformer is installed does not exceed 3300 feet (1000 meters). What are insulation classes? Insulation classes were originally used to distinguish insulating materials operating at different temperatures. In the past, letters were used for the different designations. Recently, insulation system temperatures (°C) have replaced the letters’ designations. Insulation Classes Previous Designation Insulation System Rating (°C) Class A 105 Class B 150 Class F 180 Class H 220 Class R 220 How do you know if the enclosure temperature is too hot? UL and CSA standards strictly regulate the highest temperature that an enclosure can reach. For ventilated transformers, the temperature of the enclosure should not increase by more than 50°C in a 40°C ambient at full rated current. For encapsulated transformers, the temperature of the enclosure should not increase by more than 65°C in a Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 25°C ambient at full rated current. This means that it is permissible for the temperature of the enclosure to reach 90°C (194°F). Although this temperature is very warm to the touch, it is within the allowed standards. A thermometer should be used to measure enclosure temperatures, not your hand. Can transformers be reverseconnected (reverse-fed)? Yes, with limitations. Eaton single-phase transformers rated 3 kVA and larger can be reverse-connected without any loss of kVA capacity or any adverse effects. Transformers rated 2 kVA and below, because there is a turns ratio compensation on the low voltage winding that adjusts voltage between no load and full load conditions, should not be reverse-fed. Three-phase transformers with either delta-delta or delta-wye configurations can also be reverseconnected for step-up operation. When reversefeeding a delta-wye connected transformer, there are two important considerations to take into account: (1) The neutral is not connected, only the three-phase wires of the wye system are connected, and (2) the ground strap between X0 and the enclosure must be removed. Due to high inrush currents that may be created in these applications, it is recommended that you do not reverse-feed transformers rated more than 75 kVA. The preferred solution is to purchase an Eaton step-up transformer designed specifically for your application. Transformers Transformer Standards, Technical Data and Accessories Can transformers be connected in parallel? Yes, with certain restrictions. For single-phase transformers being connected in parallel, the voltages and impedances of the transformers must be equal (impedances must be within 7.5% of each other). For three-phase transformers, the same restrictions apply as for single-phase transformers, plus the phase shift of the transformers must be the same. For example, a deltawye–connected transformer (30° phase shift) must be connected in parallel with another delta-wye–connected transformer, not a delta-delta connected–transformer (0° phase shift). Why is the impedance of a transformer important? The impedance of a transformer is important because it is used to determine the interrupting rating and trip rating of the circuit protection devices on the load or line side of the transformer. To calculate the maximum short circuit current on the load side of a transformer, use the following formula: Maximum Short Circuit = Load Current (Amps) Full Load Current (Amps) Transformer Impedance Full load current for singlephase circuits is: Nameplate Volt-Amps -----------------------------------------------------Load (output) Voltage and for three-phase circuits, the full load current is: Nameplate Volts-Amps -----------------------------------------------------Load (output) Volts 3 Example: For a standard three-phase, 75 kVA transformer, rated 480 volt delta primary and 208Y/ 120 volt secondary (catalog number V48M28T75J) and impedance equal to 5.1%, the full load current is: 2.6 What clearances are required around transformers when they are installed? All dry-type transformers depend upon the circulation of air for cooling; therefore, it is important that the flow of air around a transformer not be impeded. UL 1561 requires that there be no less than 6 inches (152.4 mm) clearance between any side transformer with ventilation openings and any wall or obstruction. In compliance with NEC 450.9, Eaton’s ventilated transformers have a note on their nameplates requiring a minimum of 6 inches (152.4 mm) clearance from the ventilation openings and walls or other obstructions. This clearance only addresses the ventilation needs of the transformer. There may be additional local codes and standards that affect installation clearances. 2 2 2 2 2 2 2 2 2 2 2 2 2 Transformers should not be mounted in such a manner that one unit will contribute to the additional heating of another unit, beyond allowable temperature limits, for example, where two units are mounted on a wall one above the other. 2 2 2 2 2 75,000 VA ----------------------------- = 208.2A 208V 1.732 2 The maximum short circuit load current is: 2 208.2A ------------------ = 4,082.4A 0.051 2 The circuit breaker or fuse on the secondary side of this transformer would have to have a minimum interrupting capacity of 4083 amperes at 208 volts. NEMA ST-20 (1992). 2 2 2 A similar transformer with lower impedance would require a primary circuit breaker or fuse with a higher interrupting capacity. 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-215 2.7 2 2 2 Transformers Dimensions Dimensions Approximate Dimensions in Inches (mm) Enclosure Dimensional Drawings—Ventilated Transformers Outside Width 2 2 Outside Width Top 2 2 2 Top Outside Width Outside Height Front Left Top Front 2 2 Outside Height Outside Height Outside Length 2 Left Left Front Drawing 1 2 2 2 Outside Length 2 Outside Length Drawing 2 2 Drawing 3 2 2 Drawing Number Dimensions Frame Height Width Length FR816 1 31.30 (795.0) 22.89 (581.4) 18.39 (467.2) 2 FR818 1 37.59 (954.8) 22.89 (581.4) 20.36 (517.1) FR819 2 42.03 (1067.6) 24.22 (615.2) 23.84 (605.5) 2 FR820 2 42.03 (1067.6) 24.22 (615.2) 23.84 (605.5) FR814 2 62.91 (1597.9) 29.97 (761.2) 33.97 (862.8) 2 FR842 1 33.75 (857.3) 22.45 (570.2) 17.40 (442.0) FR843 1 38.70 (983.0) 23.51 (597.2) 24.38 (619.3) 2 FR844 2 44.92 (1141.0) 26.27 (667.3) 27.12 (688.8) FR821 2 62.91 (1597.9) 29.97 (761.2) 33.97 (862.8) 2 FR912D, FR912D 1 30.00 (762.0) 23.00 (584.2) 16.50 (419.1) FR914D/FR914F 1 39.00 (990.6) 29.00 (736.6) 22.00 (558.8) 2 FR915D/FR915F 1 39.00 (990.6) 29.00 (736.6) 22.00 (558.8) FR916A 2 48.56 (1233.4) 28.22 (716.8) 23.42 (594.9) 2 FR917 2 56.17 (1426.7) 31.44 (798.6) 24.67 (626.6) 2 FR918A 2 62.18 (1579.4) 31.44 (798.6) 30.68 (779.3) FR923 2 57.54 (1461.5) 36.69 (931.9) 32.65 (829.3) FR924 2 68.37 (1736.6) 44.46 (1129.3) 36.44 (925.6) FR928 2 56.16 (1426.5) 32.93 (836.4) 27.97 (710.4) FR929 2 59.56 (1512.8) 36.72 (932.7) 32.50 (825.5) FR919 3 75.00 (1905.0) 44.20 (1122.7) 36.23 (920.2) FR920 3 75.00 (1905.0) 44.20 (1122.7) 36.23 (920.2) FR922 3 90.00 (2286.0) 69.26 (1759.2) 42.65 (1083.3) 2 2 2 2 V2-T2-216 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.7 Transformers Dimensions Approximate Dimensions in Inches (mm) 2 2 Enclosure Dimensional Drawings—Encapsulated Transformers (Type EP) Outside Width Outside Width Top Top Outside Length Right Outside ck Height Outside Length Ba 2 Top Outside Width Outside Height Right Back Outside Length 2 Outside Height Right 2 Back 2 2 Drawing 6 Drawing 8 Drawing 7 2 2 Outside Width 2 Top Outside Width 2 Outside Width Top Outside Height Outside Length Right Outside Length 2 Back Outside Height Right 2 Top Outside Height Outside Length Back Right Back 2 2 Drawing 10 Drawing 9 2 2 Drawing 11 2 Drawing Number Dimensions Frame Height Width Length FR52 6 8.91 (226.3) 4.11 (104.4) 4.00 (101.6) FR54 6 8.91 (226.3) 4.11 (104.4) 4.00 (101.6) FR55 6 8.91 (226.3) 4.11 (104.4) 4.00 (101.6) FR56 7 8.97 (227.8) 4.87 (123.7) 4.06 (103.1) FR57 7 8.97 (227.8) 4.87 (123.7) 4.91 (124.7) FR58A 7 11.28 (286.5) 5.99 (152.1) 5.75 (146.1) FR59A 7 11.28 (286.5) 5.99 (152.1) 5.75 (146.1) FR67 7 13.41 (340.6) 6.37 (161.8) 6.52 (165.6) FR68 7 13.41 (340.6) 6.37 (161.8) 6.52 (165.6) FR176 8 14.25 (361.9) 7.69 (195.3) 8.00 (203.2) FR177 9 16.00 (406.4) 10.38 (263.7) 9.89 (251.2) FR301 11 22.26 (565.4) 12.71 (322.8) 12.79 (324.9) FR178 9 16.00 (406.4) 10.38 (263.7) 9.89 (251.2) FR302 11 25.26 (641.6) 12.71 (322.8) 12.79 (324.9) FR304 11 25.26 (641.6) 14.72 (373.9) 14.82 (376.4) FR179 9 19.00 (482.6) 13.38 (339.9) 10.52 (267.2) FR180 9 19.00 (482.6) 13.38 (339.9) 10.52 (267.2) FR182 10 23.31 (592.1) 16.35 (415.3) 14.12 (358.6) FR190 10 26.31 (668.3) 16.35 (415.3) 14.12 (358.6) Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2 2 2 2 2 2 2 2 2 2 2 2 V2-T2-217 2.7 Transformers Dimensions 2 Approximate Dimensions in Inches (mm) 2 Enclosure Dimensional Drawings—Encapsulated Transformers Type EP (Single-Phase), continued 2 Outside Width 2 Top 2 Outside Width 2 2 Outside Length Outside Height Left Top Front Outside Width 2 2 Top Outside Height Outside Length 2 Drawing 13 Front 2 Left Outside Length Outside Height Right Back 2 2 2 Drawing 14 Drawing 12 2 2 Drawing Number Dimensions Frame Height Width FR132 13 20.67 (525.0) 19.02 (483.1) 13.59 (345.2) 2 FR300A 12 28.24 (717.3) 22.42 (569.5) 14.06 (357.1) FR57P 14 9.34 (237.2) 4.45 (113.0) 5.18 (131.6) 2 FR58AP 14 11.68 (296.7) 4.99 (126.7) 5.99 (152.1) FR567P 14 13.03 (330.9) 5.74 (145.8) 6.56 (166.6) FR568P 14 13.78 (350.0) 6.22 (158.0) 6.32 (160.5) 2 2 Length 2 2 2 2 2 2 2 2 2 2 V2-T2-218 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.7 Transformers Dimensions Approximate Dimensions in Inches (mm) 2 Enclosure Dimensional Drawings—Encapsulated Transformers (Type EPT) 2 Outside Length Outside Width 2 2 Outside Width Top Top Outside Height Front Outside Height Outside Height Front Left 2 Top Left Left 2 2 Front 2 Outside Length Drawing 15 Drawing 16 2 Outside Width Outside Length 2 2 Drawing 17 2 Dimensions Frame Drawing Number Height Width Length FR201 15 13.40 (340.4) 15.93 (404.6 8.26 (209.8) FR102 15 13.12 (333.2) 19.59 (497.6) 7.09 (180.1) FR103 15 15.90 (403.9) 16.93 (430.0) 10.01 (254.3) FR200 15 15.90 (403.9) 16.93 (430.0) 10.01 (254.3) FR97 15 15.19 (385.8) 25.68 (652.3) 8.38 (212.9) FR95 15 17.38 (441.5) 20.00 (508.0) 10.52 (267.2) FR243 16 17.38 (441.5) 20.00 (508.0) 10.52 (267.2) FR96 15 16.19 (411.2) 29.68 (753.9) 9.42 (239.3) FR244 16 28.15 (715.0) 26.58 (675.1) 14.66 (372.4) FR245 17 32.06 (814.3) 30.29 (769.4) 15.68 (398.3) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-219 2.7 Transformers Dimensions 2 Approximate Dimensions in Inches (mm) 2 Enclosure Dimensional Drawings—Core-Coil Transformers 2 Top 2 2 2 2 2 Top Outside Height 2 Outside Height 2 2 2 2 Front Front Left 2 Outside Width Outside Length 2 2 Drawing 5 Drawing Number Dimensions Frame Height Width Length 2 FR817C 4 39.28 (997.7) 21.62 (549.1) 19.51 (495.6) FR818C 4 39.28 (997.7) 21.62 (549.1) 19.51 (495.6) 2 FR912C 5 24.75 (628.7) 19.50 (495.3) 14.00 (355.6) FR914C 5 29.37 (746.0) 25.12 (638.0) 19.00 (482.6) 2 FR915C 5 31.38 (1067.6) 25.12 (638.0) 19.00 (482.6) 2 FR9516C 5 41.43 (1052.3) 25.12 (638.0) 20.00 (508.0) FR916AC 5 43.40 (1102.4) 27.22 (691.4) 22.82 (579.6) 2 Outside Length Drawing 4 2 2 2 2 2 2 2 2 2 V2-T2-220 Outside Width Left Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com 2.7 Transformers Dimensions Approximate Dimensions in Inches (mm) 2 Enclosure Dimensional Drawings—Totally Enclosed Nonventilated Transformers 2 2 Outside Width 2 2 Top Outside Width Top 2 2 Outside Width 2 Front Outside Height 2 Top Front Left Outside Height Outside Height Outside Length 2 Left Left 2 2 Front Drawing 26 2 2 2 Outside Length Outside Length Drawing 27 2 2 Drawing 28 2 Drawing Number Dimensions Frame Height Width Length FR818N 26 37.59 (954.8) 22.89 (581.4) 20.36 (517.1) FR819N 27 42.03 (1067.6) 24.22 (615.2) 23.84 (605.5) FR820N 27 42.03 (1067.6) 24.22 (615.2) 23.84 (605.5) FR814N 27 62.91 (1597.9) 29.97 (761.2) 33.97 (862.8) FR912DN 26 30.00 (762.0) 23.00 (584.2) 16.50 (419.1) FR914DN/FR914FN 26 39.18 (995.2) 29.00 (736.6) 22.00 (558.8) FR915DN/FR915FN 26 39.18 (995.2) 29.00 (736.6) 22.00 (558.8) FR916AN 27 46.58 (1183.1) 28.22 (716.8) 23.42 (594.9) FR917N 27 56.18 (1427.0) 31.44 (798.6) 24.67 (626.8) FR918AN 27 62.18 (1579.4) 31.44 (798.6) 30.68 (779.3) FR923N 27 57.50 (1460.5) 36.69 (931.9) 32.65 (829.3) FR919N 28 75.00 (1905.0) 44.21 (1122.9) 36.23 (920.2) FR920N 28 75.00 (1905.0) 44.21 (1122.9) 36.23 (920.2) 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-221 2.7 Transformers Dimensions 2 Approximate Dimensions in Inches (mm) 2 Enclosure Dimensional Drawings—Hazardous Location Transformers (Type EPZ) 2 Outside Length 2 Right Back Back 2 Top Outside Height Outside Height Right Outside Height Right Outside Width 2 2 Back Outside Width Drawing 21 Drawing 22 2 Outside Width 2 2 Drawing 23 Outside Length 2 Outside Length Top 2 Top 2 Outside Height 2 Right Outside Height Back 2 Right Back 2 2 Outside Width Outside Width 2 Drawing 24 2 2 Drawing 25 2 Drawing Number Dimensions Frame Height Width Length 2 FR57H 21 8.97 (227.8) 4.87 (123.7) 4.91 (124.7) FR58H 22 11.28 (286.5) 5.99 (152.1) 5.75 (146.1) 2 FR59H 22 11.28 (286.5) 5.99 (152.1) 5.75 (146.1) FR67H 22 13.41 (340.6) 6.37 (161.8) 6.52 (165.6) 2 FR68H 22 13.41 (340.6) 6.37 (161.8) 6.52 (165.6) FR176H 23 14.25 (361.9) 7.69 (195.3) 8.00 (203.2) 2 FR177H 24 16.00 (406.4) 10.38 (263.7) 9.89 (251.2) 2 FR178H 24 16.00 (406.4) 10.38 (263.7) 9.89 (251.2) FR179H 24 19.00 (482.6) 13.38 (339.9) 10.52 (267.2) FR180H 24 19.00 (482.6) 13.38 (339.9) 10.52 (267.2) FR182H 25 23.31 (592.1) 16.35 (415.3) 14.12 (358.6) 2 Outside Length Top Top 2 2 Outside Width Outside Length 2 V2-T2-222 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com Transformers Dimensions 2.7 Approximate Dimensions in Inches (mm) 2 Enclosure Dimensional Drawings—Hazardous Location Transformers (Type EPTZ) 2 2 Outside Length Outside Width Top Outside Width Left 2 Outside Height Front Front 2 Top Outside Height Outside Height 2 Top 2 Front Left 2 Left Outside Width Outside Length 2 Outside Length Drawing 18 Drawing 19 2 Drawing 20 2 2 Dimensions Frame Drawing Number Height Width Length FR201H 18 13.40 (340.4) 15.93 (404.6) 8.26 (209.8) FR200H 18 15.90 (403.9) 16.93 (430.0) 10.01 (254.3) FR103H 18 15.90 (403.9) 16.93 (430.0) 10.01 (254.3) FR95H 18 17.38 (441.5) 20.00 (508.0) 10.52 (267.2) FR243H 19 17.38 (441.5) 20.00 (508.0) 10.52 (267.2) FR244H 19 28.15 (715.0) 26.58 (675.1) 14.66 (372.4) FR245H 20 32.06 (814.3) 30.29 (769.4) 15.68 (398.3) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com V2-T2-223
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Zoltun Design Create Date : 2016:10:22 15:07:20+05:30 Modify Date : 2016:10:22 15:07:20+05:30 Subject : Transformers XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Producer : Acrobat Distiller 11.0 (Windows) Format : application/pdf Creator : Zoltun Design Title : Volume 2 Tab 2 Description : Transformers Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2016:07:01 09:15:04-05:00 Document ID : uuid:b49bc77b-421f-4247-ab40-c8df8299ec00 Instance ID : uuid:45c56213-284e-4612-9e3d-aa294d77f9dc Page Count : 223EXIF Metadata provided by EXIF.tools