Transformers
Dry-Type Transformer Family

2.1

NEMA TP-1 Energy-Efficient Transformers
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.2

NEMA Premium and E3 Super Efficient Transformers
NEMA Premium® Efficient Transformers . . . . . . . . . . . . . . . . . . . . . .
E3 Super Efficient Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.3

V2-T2-111
V2-T2-119
V2-T2-124
V2-T2-127
V2-T2-130
V2-T2-133
V2-T2-144
V2-T2-173

Transformer Standards, Technical Data and Accessories
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Glossary of Transformer Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Frequently Asked Questions About Transformers. . . . . . . . . . . . . . . .

2.7

V2-T2-93
V2-T2-93
V2-T2-93
V2-T2-93
V2-T2-94
V2-T2-94
V2-T2-109
V2-T2-109

Distribution Transformers
Motor Drive Isolation Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Totally Enclosed Non-Ventilated Transformers . . . . . . . . . . . . . . . . . .
Class I, Division 2, Hazardous Location Transformers . . . . . . . . . . . . .
Open-Type Core and Coil Assembly Transformers . . . . . . . . . . . . . . .
Marine Duty Transformers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Buck-Boost and Low Voltage Lighting Transformers . . . . . . . . . . . . . .
Medium Voltage Distribution Transformers. . . . . . . . . . . . . . . . . . . . .

2.6

V2-T2-71
V2-T2-71
V2-T2-72
V2-T2-72
V2-T2-73
V2-T2-89
V2-T2-89

General-Purpose Encapsulated Transformers
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.5

V2-T2-61
V2-T2-66

Energy-Efficient Harmonic Mitigating Transformers
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.4

V2-T2-2
V2-T2-2
V2-T2-3
V2-T2-3
V2-T2-4
V2-T2-4
V2-T2-50
V2-T2-50

V2-T2-186
V2-T2-187
V2-T2-189
V2-T2-191
V2-T2-195
V2-T2-211
V2-T2-214

Dimensions
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V2-T2-216

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-1

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Contents

Type DT-3

Description

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Product Description

Application Description

Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.

NEMA TP-1-2002 compliant
energy-efficient transformers
are specifically designed to
meet the energy efficiency
standards set forth in NEMA
Standards publication, TP-12002, “Guide for Determining
Energy Efficiency for
Distribution Transformers.”
Surveys have shown that
the average loading of low
voltage dry-type distribution
transformers, over a 24-hour
period, is approximately
35%. NEMA TP-1 compliant
transformers are optimized to
offer maximum efficiency at
35% of nameplate rating.

Types DS-3, DT-3
●

●

2
2
2
2
2
2
2

Page

NEMA TP-1 Energy-Efficient Transformers
Features, Benefits and Functions. . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection. . . . . . . . . . . . . . . . . . . . . . .
Single-Phase Aluminum . . . . . . . . . . . . . . . .
Single-Phase Copper . . . . . . . . . . . . . . . . . . .
Single-Phase Shielded Aluminum . . . . . . . . .
Single-Phase Shielded Copper . . . . . . . . . . .
Three-Phase Aluminum . . . . . . . . . . . . . . . . .
Three-Phase Copper . . . . . . . . . . . . . . . . . . .
Three-Phase Shielded Aluminum . . . . . . . . .
Three-Phase Shielded Copper . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
K-Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Aluminum . . . . . . . . . . . . . . . . . . . . . . . . . . .
Copper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

●
●
●

●

●

Ventilated, NEMA 2
enclosure standard
Suitable for indoor
applications, outdoors
when weathershields
are also installed
Upright mounting only
220ºC insulation system
150ºC rise standard;
115°C or 80°C rise optional
Available in single-phase
ratings 15–167 kVA,
600 volts primary (DS-3)
Available in three-phase
ratings 15–1500 kVA
and up to 600 volts
primary (DT-3)

2

The range of products covered
by NEMA TP-1-2002 are:

2

●

●

●

●

●
●

●

●

NEMA TP-1-2002
Product Range
Rating

●

Voltage
Class

Voltage

Primary
voltage

34.5 kV and
below

Secondary
voltage

600V and
below

●

Dry-Type Single-phase 10–833 kVA
Rating
Three-phase 15–2500 kVA

2

Transformers that are
currently specifically excluded
from the scope of NEMA
Standard TP-1-2002 include:

Liquid
Rating

●
●

●

●
●

Liquid-filled transformers
below 10 kVA
Dry-type transformers
below 15 kVA
AC and DC drives
transformers
Rectifier transformers
designed for high
harmonics
Autotransformers
Non-distribution
transformers, such as
UPS transformers
Special impedance or
regulation transformers
Regulating transformers
Sealed and non-ventilated
transformers
Machine tool transformers
Welding transformers
Transformers with tap
ranges greater than 15%
Transformers with a
frequency other than 60 Hz
Grounding transformers
Testing transformers

Single-phase 10–833 kVA
Three-phase

15–2500 kVA

2
2
V2-T2-2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-3
V2-T2-3
V2-T2-4
V2-T2-4
V2-T2-4
V2-T2-6
V2-T2-8
V2-T2-10
V2-T2-12
V2-T2-23
V2-T2-34
V2-T2-42
V2-T2-50
V2-T2-50
V2-T2-51
V2-T2-52
V2-T2-57

Efficiency levels set forth in
NEMA TP-1-2002.
NEMA TP-1-2002
Efficiency Levels
Tables of Energy Efficiency
NEMA Class 1 Efficiency Levels
Dry-Type Distribution Transformers—
Low Voltage (600V and below)
Single-Phase

Three-Phase

kVA Efficiency

kVA

Efficiency

15

97.7

15

97.0

25

98.0

30

97.5

37.5 98.2

45

97.7

50

75

98.0

98.3

75

98.5

112.5

98.2

100

98.6

150

98.3

167

98.7

225

98.5

250

98.8

300

98.6

333

98.9

500

98.7

—

—

750

98.8

—

—

1000

98.9

Transformers
NEMA TP-1 Energy-Efficient Transformers

Features, Benefits
and Functions
●

●

●

●

60 Hz operation (except
as noted)
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels
Meet federal energy
efficiency requirements
for low voltage dry-type
distribution transformers
effective as of
January 1, 2007

2.1

Standards and
Certifications
●

2
2

UL® listed

2
2

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards. All
600 volt class transformers
are UL listed unless
otherwise noted.

2
2
2
2
2

Seismically Qualified
Eaton manufactured dry-type
distribution transformers are
seismically qualified and
exceed requirements of the
Uniform Building Code (UBC),
International Building Code
(IBC) and California Code
Title 24.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-3

2.1
2
2
2
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Catalog Number Selection
Please refer to Section 2.7 Page V2-T2-187.

Product Selection
Additional Product Selection information begins on Page V2-T2-189.

Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2

208 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

260A

226 (103)

WS11

T29M11S15EE

2

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

260A

346 (157)

WS11

T29M11S25EE

37.5

2 at +2.5%

4 at –2.5

DS-3

150

818

260A

374 (170)

WS11

T29M11S37EE

2

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

260A

545 (247)

WS16

T29M11S50EE

75

1 at +5%

2 at –5%

DS-3

150

819

551A

568 (258)

WS16

T29R11S75EE

2

100

1 at +5%

2 at –5%

DS-3

150

814E

449A

1178 (535)

WS13

T29R11S99EE

2
2

Full Capacity Taps

240 x 480 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2

2

DS-3

150

842

3XA

196 (89)

WS45

T20P11S15AEE

2

25

2

2

DS-3

150

842

3XA

261 (118)

WS45

T20P11S25AEE

37.5

2

2

DS-3

150

843

3XA

304 (138)

WS43

T20P11S37AEE

2

50

2

2

DS-3

150

843

3XA

396 (180)

WS43

T20P11S50AEE

75

2

2

DS-3

150

844

3XA

688 (312)

WS44

T20P11S75AEE

2

100

2

2

DS-3

150

844

3XA

699 (317)

WS44

T20P11S99AEE

2

167

2 at +2.5%

4 at –2.5%

DS-3

150

814E

288A

1294 (587)

WS13

T48M11S67EE 3

15

2

2

DS-3

115

816

3XA

246 (112)

WS11

T20P11F15EE

2

25

2

2

DS-3

115

818

3XA

373 (169)

WS11

T20P11F25EE

37.5

2

2

DS-3

115

818

3XA

380 (173)

WS11

T20P11F37EE

2

50

2

2

DS-3

115

819

3XA

590 (268)

WS16

T20P11F50EE

2

2

2

75

DS-3

115

820

3XA

691 (314)

WS16

T20P11F75EE

100

2

2

DS-3

115

821

3XA

844 (383)

WS13

T20P11F99EE

2

15

2

2

DS-3

80

818

3XA

360 (163)

WS11

T20P11B15EE

25

2

2

DS-3

80

818

3XA

370 (168)

WS11

T20P11B25EE

2

37.5

2

2

DS-3

80

819

3XA

565 (257)

WS16

T20P11B37EE

50

2

2

DS-3

80

820

3XA

680 (309)

WS16

T20P11B50EE

75

2

2

DS-3

80

821

3XA

900 (409)

WS13

T20P11B75EE

2

2
2
2
2

Notes
1 Weights subject to change.
2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary.
3 480 volt primary only.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
V2-T2-4

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2
2

277 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

262C

220 (100)

WS11

T27M11S15EE

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

262C

346 (157)

WS11

T27M11S25EE

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

262C

391 (178)

WS11

T27M11S37EE

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

262C

555 (252)

WS16

T27M11S50EE

75

1 at +5%

2 at –5%

DS-3

150

819

2

568 (258)

WS16

T27R11S75EE

100

1 at +5%

2 at –5%

DS-3

150

814E

2

1178 (535)

WS13

T27R11S99EE

2
2
2
2
2
2

208 x 416 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

3

3

DS-3

150

816

3XF

246 (112)

WS11

T18P11S15EE

25

3

3

DS-3

150

818

3XF

359 (163)

WS11

T18P11S25EE

37.5

3

3

DS-3

150

818

3XF

374 (170)

WS11

T18P11S37EE

50

3

3

DS-3

150

819

3XF

555 (252)

WS16

T18P11S50EE

75

3

3

DS-3

150

820

3XF

665 (302)

WS16

T18P11S75EE

100

3

3

DS-3

150

821

3XF

841 (382)

WS13

T18P11S99EE

2
2
2
2
2
2

600 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

262B

243 (110)

WS11

T60M11S15EE

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

262B

355 (161)

WS11

T60M11S25EE

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

262B

375 (170)

WS11

T60M11S37EE

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

262B

594 (270)

WS16

T60M11S50EE

75

2 at +2.5%

4 at –2.5%

DS-3

150

820

262B

755 (343)

WS16

T60M11S75EE

100

2 at +2.5%

4 at –2.5%

DS-3

150

821

262B

865 (393)

WS13

T60M11S99EE

2
2
2
2
2

Notes
1 Weights subject to change.
2 Contact your local Eaton sales office for these details.
3 1 at +5%, 2 at –5% at 208 volts primary; 2 at +2.5%, 4 at –2.5% at 416 volts primary.

2
2

For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-5

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2

208 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

260A

275 (125)

WS11

T29M11S15CUEE

2

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

260A

390 (177)

WS11

T29M11S25CUEE

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

260A

440 (200)

WS11

T29M11S37CUEE

2

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

260A

661 (300)

WS16

T29M11S50CUEE

75

1 at +5%

2 at –5%

DS-3

150

820

551A

805 (365)

WS16

T29R11S75CUEE

2

100

1 at +5%

2 at –5%

DS-3

150

821

449A

970 (440)

WS13

T29R11S99CUEE

Full Capacity Taps

2

240 x 480 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2

2

DS-3

150

816

3XA

270 (123)

WS11

T20P11S15CUEE

2

25

2

2

DS-3

150

818

3XA

406 (184)

WS11

T20P11S25CUEE

37.5

2

2

DS-3

150

818

3XA

453 (206)

WS11

T20P11S37CUEE

2

50

2

2

DS-3

150

819

3XA

657 (298)

WS16

T20P11S50CUEE

75

2

2

DS-3

150

820

3XA

803 (365)

WS16

T20P11S75CUEE

2

100

2

2

DS-3

150

821

3XA

960 (436)

WS13

T20P11S99CUEE

2

167

2 at +2.5%

4 at –2.5%

DS-3

150

814E

288A

1665 (756)

WS13

T48M11S67CUEE 3

15

2

2

DS-3

115

816

3XA

264 (120)

WS11

T20P11F15CUEE

2

25

2

2

DS-3

115

818

3XA

420 (191)

WS11

T20P11F25CUEE

37.5

2

2

DS-3

115

818

3XA

450 (204)

WS11

T20P11F37CUEE

2

50

2

2

DS-3

115

819

3XA

703 (319)

WS16

T20P11F50CUEE

75

2

2

DS-3

115

820

3XA

793 (360)

WS16

T20P11F75CUEE

2

100

2

2

DS-3

115

821

3XA

1085 (493)

WS13

T20P11F99CUEE

2

15

2

2

DS-3

80

818

3XA

407 (185)

WS11

T20P11B15CUEE

25

2

2

DS-3

80

818

3XA

430 (195)

WS11

T20P11B25CUEE

2

37.5

2

2

DS-3

80

819

3XA

685 (311)

WS16

T20P11B37CUEE

50

2

2

DS-3

80

820

3XA

799 (363)

WS16

T20P11B50CUEE

2

75

2

2

DS-3

80

821

3XA

1056 (479)

WS13

T20P11B75CUEE

2

Full Capacity Taps

2

277 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

262C

275 (125)

WS11

T27M11S15CUEE

2

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

262C

390 (177)

WS11

T27M11S25CUEE

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

262C

440 (200)

WS11

T27M11S37CUEE

2

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

262C

661 (300)

WS16

T27M11S50CUEE

75

1 at +5%

2 at –5%

DS-3

150

820

4

805 (365)

WS16

T27R11S75CUEE

100

1 at +5%

2 at –5%

DS-3

150

821

4

970 (440)

WS13

T27R11S99CUEE

2

2
2
2
2

Full Capacity Taps

Notes
1 Weights subject to change.
2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary.
3 480 volt primary only.
4 Contact your local Eaton sales office for these details.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
V2-T2-6

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2
2

208 x 416 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

15

1

1

DS-3

150

816

3XF

275 (125)

WS11

T18P11S15CUEE

25

1

1

DS-3

150

818

3XF

390 (177)

WS11

T18P11S25CUEE

37.5

1

1

DS-3

150

818

3XF

440 (200)

WS11

T18P11S37CUEE

50

1

1

DS-3

150

819

3XF

661 (300)

WS16

T18P11S50CUEE

75

1

1

DS-3

150

820

3XF

805 (365)

WS16

T18P11S75CUEE

100

1

1

DS-3

150

821

3XF

970 (440)

WS13

T18P11S99CUEE

2
2
2
2
2
2

600 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

262B

290 (132)

WS11

T60M11S15CUEE

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

262B

465 (211)

WS11

T60M11S25CUEE

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

262B

495 (225)

WS11

T60M11S37CUEE

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

262B

775 (352)

WS16

T60M11S50CUEE

75

2 at +2.5%

4 at –2.5%

DS-3

150

820

262B

900 (409)

WS16

T60M11S75CUEE

100

2 at +2.5%

4 at –2.5%

DS-3

150

821

262B

1195 (543)

WS13

T60M11S99CUEE

2
2
2
2
2

Notes
1 1 at +5%, 2 at –5% at 208 volts primary; 2 at +2.5%, 4 at –2.5% at 416 volts primary.
2 Weights subject to change.

2
2

For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-7

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings

2

208 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

264A

275 (125)

WS11

T29M11E15EE

2

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

264A

390 (177)

WS11

T29M11E25EE

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

264A

440 (200)

WS11

T29M11E37EE

2

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

264A

661 (300)

WS16

T29M11E50EE

75

1 at +5%

2 at –5%

DS-3

150

820

450A

805 (366)

WS16

T29R11E75EE

2

100

1 at +5%

2 at –5%

DS-3

150

821

450A

970 (440)

WS13

T29R11E99EE

Full Capacity Taps

2

240 x 480 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2

2

DS-3

150

816

261A

246 (112)

WS11

T20P11E15EE

2

25

2

2

DS-3

150

818

261A

359 (163)

WS11

T20P11E25EE

37.5

2

2

DS-3

150

818

261A

374 (170)

WS11

T20P11E37EE

2

50

2

2

DS-3

150

819

261A

555 (252)

WS16

T20P11E50EE

75

2

2

DS-3

150

820

261A

740 (336)

WS16

T20P11E75EE

2

100

2

2

DS-3

150

821

261A

841 (382)

WS13

T20P11E99EE

2

167

2 at +2.5%

4 at –2.5%

DS-3

150

814E

227A

1294 (587)

WS13

T48M11E67EE 3

15

2

2

DS-3

115

816

261A

246 (112)

WS11

T20P11F15EEES

2

25

2

2

DS-3

115

818

261A

373 (169)

WS11

T20P11F25EEES

37.5

2

2

DS-3

115

818

261A

380 (173)

WS11

T20P11F37EEES

2

50

2

2

DS-3

115

819

261A

590 (268)

WS16

T20P11F50EEES

75

2

2

DS-3

115

820

261A

691 (314)

WS16

T20P11F75EEES

2

100

2

2

DS-3

115

821

261A

844 (383)

WS13

T20P11F99EEES

2

15

2

2

DS-3

80

818

261A

360 (163)

WS11

T20P11B15EEES

25

2

2

DS-3

80

818

261A

370 (168)

WS11

T20P11B25EEES

2

37.5

2

2

DS-3

80

819

261A

565 (257)

WS16

T20P11B37EEES

50

2

2

DS-3

80

820

261A

680 (309)

WS16

T20P11B50EEES

2

75

2

2

DS-3

80

821

261A

900 (409)

WS13

T20P11B75EEES

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

Full Capacity Taps

2

277 Volts to 120/240 Volts

2

kVA

2

Full Capacity Taps
FCAN

FCBN

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

4

275 (125)

WS11

T27M11E15EE

2

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

4

390 (177)

WS11

T27M11E25EE

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

4

440 (200)

WS11

T27M11E37EE

2

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

4

661 (300)

WS16

T27M11E50EE

75

1 at +5%

2 at –5%

DS-3

150

820

4

805 (366)

WS16

T27R11E75EE

100

1 at +5%

2 at –5%

DS-3

150

821

4

970 (440)

WS13

T27R11E99EE

2
2
2
2

Notes
1 Weights subject to change.
2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary.
3 480 volt primary only.
4 Contact your local Eaton sales office for these details.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
V2-T2-8

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings

2
2

208 x 416 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

15

1

1

DS-3

150

816

243H

275 (125)

WS11

T43P11E15EE

25

1

1

DS-3

150

818

243H

390 (177)

WS11

T43P11E25EE

37.5

1

1

DS-3

150

818

243H

440 (200)

WS11

T43P11E37EE

50

1

1

DS-3

150

819

243H

661 (300)

WS16

T43P11E50EE

75

1

1

DS-3

150

820

3

805 (366)

WS16

T43P11E75EE

100

1

1

DS-3

150

821

3

970 (440)

WS13

T43P11E99EE

2
2
2
2
2
2

600 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

259A

275 (125)

WS11

T60M11E15EE

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

259A

390 (177)

WS11

T60M11E25EE

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

259A

440 (200)

WS11

T60M11E37EE

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

259A

661 (300)

WS16

T60M11E50EE

75

1 at +5%

2 at –5%

DS-3

150

820

3

805 (366)

WS16

T60R11E75EE

100

1 at +5%

2 at –5%

DS-3

150

821

3

970 (440)

WS13

T60R11E99EE

2
2
2
2
2

Notes
1 1 at +5%, 2 at –5% at 208 volts primary; 2 at +2.5%, 4 at –2.5% at 416 volts primary.
2 Weights subject to change.
3 Contact your local Eaton sales office for these details.

2
2

For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-9

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings

2

208 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

264A

270 (123)

WS11

T29M11E15CUEE

2

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

264A

423 (192)

WS11

T29M11E25CUEE

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

264A

437 (198)

WS11

T29M11E37CUEE

2
2

Full Capacity Taps

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

264A

620 (281)

WS16

T29M11E50CUEE

75

1 at +5%

2 at –5%

DS-3

150

820

450A

810 (368)

WS16

T29R11E75CUEE

100

1 at +5%

2 at –5%

DS-3

150

821

450A

980 (445)

WS13

T29R11E99CUEE

2

240 x 480 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2

2

DS-3

150

816

261A

270 (123)

WS11

T20P11E15CUEE

2

25

2

2

DS-3

150

818

261A

423 (192)

WS11

T20P11E25CUEE

37.5

2

2

DS-3

150

818

261A

437 (198)

WS11

T20P11E37CUEE

2

50

2

2

DS-3

150

819

261A

620 (281)

WS16

T20P11E50CUEE

75

2

2

DS-3

150

820

261A

810 (368)

WS16

T20P11E75CUEE

2

100

2

2

DS-3

150

821

261A

980 (445)

WS13

T20P11E99CUEE

2

2

2

15

DS-3

115

816

261A

254 (115)

WS11

T20P11F15CUEEES

25

2

2

DS-3

115

818

261A

453 (206)

WS11

T20P11F25CUEEES

2

37.5

2

2

DS-3

115

818

261A

480 (218)

WS11

T20P11F37CUEEES

50

2

2

DS-3

115

819

261A

718 (326)

WS16

T20P11F50CUEEES

2

75

2

2

DS-3

115

820

261A

793 (360)

WS16

T20P11F75CUEEES

100

2

2

DS-3

115

821

261A

1000 (454)

WS13

T20P11F99CUEEES

15

2

2

DS-3

80

818

261A

240 (109)

WS11

T20P11B15CUEEES

25

2

2

DS-3

80

818

261A

430 (195)

WS11

T20P11B25CUEEES

37.5

2

2

DS-3

80

819

261A

700 (318)

WS16

T20P11B37CUEEES

50

2

2

DS-3

80

820

261A

738 (335)

WS16

T20P11B50CUEEES

75

2

2

DS-3

80

821

261A

960 (436)

WS13

T20P11B75CUEEES

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

2
2
2

Full Capacity Taps

2
2

277 Volts to 120/240 Volts

2

kVA

2

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

3

270 (123)

WS11

T27M11E15CUEE

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

3

423 (192)

WS11

T27M11E25CUEE

2

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

3

437 (198)

WS11

T27M11E37CUEE

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

3

620 (281)

WS16

T27M11E50CUEE

2

75

1 at +5%

2 at –5%

DS-3

150

820

3

810 (368)

WS16

T27R11E75CUEE

100

1 at +5%

2 at –5%

DS-3

150

821

3

980 (445)

WS13

T27R11E99CUEE

2
2
2

Full Capacity Taps
FCAN

FCBN

Notes
1 Weights subject to change.
2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary.
3 Contact your local Eaton sales office for these details.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
V2-T2-10

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Single-Phase—Type DS-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings

2
2

208 x 416 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

15

1

1

DS-3

150

816

243H

270 (123)

WS11

T43P11E15CUEE

25

1

1

DS-3

150

818

243H

423 (192)

WS11

T43P11E25CUEE

37.5

1

1

DS-3

150

818

243H

437 (198)

WS11

T43P11E37CUEE

50

1

1

DS-3

150

819

243H

620 (281)

WS16

T43P11E50CUEE

75

1

1

DS-3

150

820

3

810 (368)

WS16

T43P11E75CUEE

100

1

1

DS-3

150

821

3

980 (445)

WS13

T43P11E99CUEE

2
2
2
2
2
2

600 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DS-3

150

816

259A

270 (123)

WS11

T60M11E15CUEE

25

2 at +2.5%

4 at –2.5%

DS-3

150

818

259A

423 (192)

WS11

T60M11E25CUEE

37.5

2 at +2.5%

4 at –2.5%

DS-3

150

818

259A

437 (198)

WS11

T60M11E37CUEE

50

2 at +2.5%

4 at –2.5%

DS-3

150

819

259A

620 (281)

WS16

T60M11E50CUEE

75

1 at +5%

2 at –5%

DS-3

150

820

3

810 (368)

WS16

T60R11E75CUEE

100

1 at +5%

2 at –5%

DS-3

150

821

3

980 (445)

WS13

T60R11E99CUEE

2
2
2
2
2

Notes
1 1 at +5%, 2 at –5% at 208 volts primary; 2 at +2.5%, 4 at –2.5% at 416 volts primary.
2 Weights subject to change.
3 Contact your local Eaton sales office for these details.

2

For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-11

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2

208 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280E

218 (99)

WS38

V29M28T15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280E

299 (136)

WS38

V29M28T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280E

376 (171)

WS38

V29M28T45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280E

564 (256)

WS39

V29M28T75EE

112.5

1 at +5%

2 at –5%

DT-3

150

916A

324A

930 (422)

WS19

V29R28T12EE

2

150

1 at +5%

2 at –5%

DT-3

150

916A

324A

1013 (460)

WS19

V29R28T49EE

225

1 at +5%

2 at –5%

DT-3

150

918A

324A

1443 (655)

WS34

V29R28T22EE

2

300

1 at +5%

2 at –5%

DT-3

150

919E

289D

1697 (770)

WS35

V29R28T33EE

2

500

1 at +5%

2 at –5%

DT-3

150

920E

289D

2690 (1221)

WS35

V29R28T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280E

240 (109)

WS38

V29M28F15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280E

320 (145)

WS38

V29M28F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280E

396 (180)

WS38

V29M28F45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280E

607 (276)

WS39

V29M28F75EE

2

112.5

1 at +5%

2 at –5%

DT-3

115

916A

324A

960 (436)

WS19

V29R28F12EE

150

1 at +5%

2 at –5%

DT-3

115

916A

324A

1060 (481)

WS19

V29R28F49EE

2

225

1 at +5%

2 at –5%

DT-3

115

918A

324A

1500 (681)

WS34

V29R28F22EE

300

1 at +5%

2 at –5%

DT-3

115

919E

289D

1800 (817)

WS35

V29R28F33EE

2

500

1 at +5%

2 at –5%

DT-3

115

920E

289D

2900 (1317)

WS35

V29R28F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280E

280 (127)

WS38

V29M28B15EE

2
2
2
2
2
2

Full Capacity Taps

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280E

350 (159)

WS38

V29M28B30EE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

280E

560 (254)

WS39

V29M28B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280E

810 (368)

WS19

V29M28B75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280E

950 (431)

WS19

V29M28B12EE

150

1 at +5%

2 at –5%

DT-3

80

918A

324A

1430 (649)

WS34

V29R28B49EE

225

1 at +5%

2 at –5%

DT-3

80

919E

289D

1750 (795)

WS35

V29R28B22EE

300

1 at +5%

2 at –5%

DT-3

80

920E

289D

2400 (1090)

WS35

V29R28B33EE

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-12

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2
2

208 Delta Volts to 480Y/277 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342B

196 (89)

WS38

V29M47T15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342B

296 (134)

WS38

V29M47T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342B

385 (175)

WS38

V29M47T45EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

342B

590 (268)

WS39

V29M47T75EE

112.5

1 at +5%

2 at –5%

DT-3

150

916A

351A

784 (356)

WS19

V29R47T12EE

150

1 at +5%

2 at –5%

DT-3

150

916A

351A

931 (423)

WS19

V29R47T49EE

225

1 at +5%

2 at –5%

DT-3

150

918A

333B

1550 (704)

WS34

V29R47T22EE

300

1 at +5%

2 at –5%

DT-3

150

919E

333B

2274 (1032)

WS35

V29R47T33EE

500

1 at +5%

2 at –5%

DT-3

150

919E

333B

2869 (1303)

WS35

V29R47T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

342B

215 (98)

WS38

V29M47F15EE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

342B

380 (173)

WS38

V29M47F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

342B

400 (182)

WS38

V29M47F45EE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

342B

585 (266)

WS39

V29M47F75EE

112.5

1 at +5%

2 at –5%

DT-3

115

916A

351A

800 (363)

WS19

V29R47F12EE

150

1 at +5%

2 at –5%

DT-3

115

916A

351A

950 (431)

WS19

V29R47F49EE

225

1 at +5%

2 at –5%

DT-3

115

918A

333B

1591 (722)

WS34

V29R47F22EE

300

1 at +5%

2 at –5%

DT-3

115

919E

333B

2320 (1053)

WS35

V29R47F33EE

500

1 at +5%

2 at –5%

DT-3

115

919E

333B

2950 (1339)

WS35

V29R47F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

342B

300 (136)

WS38

V29M47B15EE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

342B

390 (177)

WS38

V29M47B30EE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

342B

550 (249)

WS39

V29M47B45EE

75

1 at +5%

2 at –5%

DT-3

80

916A

351A

757 (344)

WS19

V29R47B75EE

112.5

1 at +5%

2 at –5%

DT-3

80

916A

351A

930 (422)

WS19

V29R47B12EE

150

1 at +5%

2 at –5%

DT-3

80

918A

333B

1550 (704)

WS34

V29R47B49EE

225

1 at +5%

2 at –5%

DT-3

80

919E

333B

2275 (1033)

WS35

V29R47B22EE

300

1 at +5%

2 at –5%

DT-3

80

920E

333B

2870 (1303)

WS35

V29R47B33EE

2

Catalog Number

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-13

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2

240 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280C

206 (94)

WS38

V24M28T15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280C

297 (135)

WS38

V24M28T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280C

332 (151)

WS38

V24M28T45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280C

562 (255)

WS39

V24M28T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280C

760 (345)

WS19

V24M28T12EE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280C

974 (442)

WS19

V24M28T49EE

225

1 at +5%

2 at –5%

DT-3

150

917

289A

1460 (663)

WS34

V24R28T22EE
V24R28T33EE

Full Capacity Taps

2

300

1 at +5%

2 at –5%

DT-3

150

918A

289A

1652 (750)

WS34

2

500

1 at +5%

2 at –5%

DT-3

150

919E

289A

2690 (1221)

WS35

V24R28T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280C

240 (109)

WS38

V24M28F15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280C

389 (177)

WS38

V24M28F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280C

396 (180)

WS38

V24M28F45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280C

593 (269)

WS39

V24M28F75EE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280C

941 (427)

WS19

V24M28F12EE

150

1 at +5%

2 at –5%

DT-3

115

916A

280C

1060 (481)

WS19

V24R28F49EE

2

225

1 at +5%

2 at –5%

DT-3

115

917

289A

1500 (681)

WS34

V24R28F22EE

300

1 at +5%

2 at –5%

DT-3

115

918A

289A

1800 (817)

WS34

V24R28F33EE

2

500

1 at +5%

2 at –5%

DT-3

115

919E

289A

2900 (1317)

WS35

V24R28F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280C

280 (127)

WS38

V24M28B15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280C

350 (159)

WS38

V24M28B30EE

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

280C

560 (254)

WS39

V24M28B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280C

883 (401)

WS19

V24M28B75EE

2

112.5

1 at +5%

2 at –5%

DT-3

80

916A

280C

950 (431)

WS19

V24R28B12EE

150

1 at +5%

2 at –5%

DT-3

80

917

289A

1430 (649)

WS34

V24R28B49EE

2

225

1 at +5%

2 at –5%

DT-3

80

918A

289A

1750 (795)

WS34

V24R28B22EE

300

1 at +5%

2 at –5%

DT-3

80

919E

289A

2400 (1090)

WS35

V24R28B33EE

2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-14

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2
2

240 Delta Volts to 480Y/277 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342L

227 (103)

WS38

V24M47T15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342L

306 (139)

WS38

V24M47T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342L

380 (173)

WS38

V24M47T45EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

342L

573 (260)

WS39

V24M47T75EE

2

Catalog Number

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

342L

800 (363)

WS19

V24M47T12EE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

342L

885 (402)

WS19

V24M47T49EE

225

1 at +5%

2 at –5%

DT-3

150

918A

333A

1612 (732)

WS34

V24R47T22EE

300

1 at +5%

2 at –5%

DT-3

150

919E

333A

1652 (750)

WS35

V24R47T33EE

500

1 at +5%

2 at –5%

DT-3

150

919E

333A

2695 (1224)

WS35

V24R47T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

342L

240 (109)

WS38

V24M47F15EE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

342L

389 (177)

WS38

V24M47F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

342L

396 (180)

WS38

V24M47F45EE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

342L

593 (269)

WS39

V24M47F75EE

112.5

1 at +5%

2 at –5%

DT-3

115

916A

342L

941 (427)

WS19

V24R47F12EE

150

1 at +5%

2 at –5%

DT-3

115

916A

342L

1060 (481)

WS19

V24R47F49EE

225

1 at +5%

2 at –5%

DT-3

115

918A

333A

1500 (681)

WS34

V24R47F22EE

300

1 at +5%

2 at –5%

DT-3

115

919E

333A

1800 (817)

WS35

V24R47F33EE

500

1 at +5%

2 at –5%

DT-3

115

919E

333A

2900 (1317)

WS35

V24R47F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

342L

280 (127)

WS38

V24M47B15EE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

342L

350 (159)

WS38

V24M47B30EE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

342L

560 (254)

WS39

V24M47B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

342L

883 (401)

WS19

V24M47B75EE

112.5

1 at +5%

2 at –5%

DT-3

80

916A

342L

950 (431)

WS19

V24R47B12EE

150

1 at +5%

2 at –5%

DT-3

80

918A

333A

1430 (649)

WS34

V24R47B49EE

225

1 at +5%

2 at –5%

DT-3

80

919E

333A

1750 (795)

WS35

V24R47B22EE

300

1 at +5%

2 at –5%

DT-3

80

919E

333A

2400 (1090)

WS35

V24R47B33EE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-15

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2

440 Delta Volts to 220Y/127 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280J

204 (93)

WS38

V44M31T15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280J

291 (132)

WS38

V44M31T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280J

351 (159)

WS38

V44M31T45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280J

553 (251)

WS39

V44M31T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280J

793 (360)

WS19

V44M31T12EE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280J

913 (415)

WS19

V44M31T49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

280J

1343 (610)

WS34

V44M31T22EE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

918A

275F

1597 (725)

WS34

V44M31T33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

275F

2590 (1176)

WS35

V44M31T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280J

202 (92)

WS38

V44M31F15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280J

311 (141)

WS38

V44M31F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280J

418 (190)

WS38

V44M31F45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280J

581 (264)

WS39

V44M31F75EE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280J

829 (376)

WS19

V44M31F12EE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280J

996 (452)

WS19

V44M31F49EE

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

280J

1569 (712)

WS34

V44M31F22EE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

280J

1908 (866)

WS37

V44M31F33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

275F

3117 (1415)

WS35

V44M31F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280J

276 (125)

WS38

V44M31B15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280J

350 (159)

WS38

V44M31B30EE

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

280J

560 (254)

WS39

V44M31B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280J

810 (368)

WS19

V44M31B75EE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280J

944 (429)

WS19

V44M31B12EE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

280J

1438 (653)

WS34

V44M31B49EE

2

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

280J

1746 (793)

WS37

V44M31B22EE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

275F

2400 (1090)

WS35

V44M31B33EE

2
2

Full Capacity Taps

Notes
1 Weights subject to change.
Additional voltage combinations are available. Contact your local Eaton sales office for assistance if the voltage you require is not included in this catalog. For other ratings or catalog numbers not
shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-16

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2
2

480 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

204 (93)

WS38

V48M28T15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

291 (132)

WS38

V48M28T30EE

37.5

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

381 (173)

WS38

V48M28T37EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

351 (159)

WS38

V48M28T45EE

50

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280B

531 (241)

WS39

V48M28T50EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280B

553 (251)

WS39

V48M28T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280B

793 (360)

WS19

V48M28T12EE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280B

913 (415)

WS19

V48M28T49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

928

657B

1160 (527)

WS41

V48M28T22EE

300

2 at +2.5%

4 at –2.5%

DT-3

150

929

657B

1415 (642)

WS42

V48M28T33EE

500

2 at +2.5%

2 at –2.5%

DT-3

150

924

428B

2415 (1097)

WS40

V48D28T55EE

750

2 at +2.5%

4 at –2.5%

DT-3

150

920E

275A

3340 (1516)

WS35

V48M28T77EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

202 (92)

WS38

V48M28F15EE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

311 (141)

WS38

V48M28F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

418 (190)

WS38

V48M28F45EE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280B

581 (264)

WS39

V48M28F75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280B

829 (376)

WS19

V48M28F12EE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280B

996 (452)

WS19

V48M28F49EE

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

280B

1569 (712)

WS34

V48M28F22EE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

280B

1908 (866)

WS37

V48M28F33EE

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

275A

3117 (1415)

WS35

V48M28F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280B

276 (125)

WS38

V48M28B15EE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280B

350 (159)

WS38

V48M28B30EE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

280B

560 (254)

WS39

V48M28B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280B

810 (368)

WS19

V48M28B75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280B

944 (429)

WS19

V48M28B12EE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

280B

1438 (653)

WS34

V48M28B49EE

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

280B

1746 (793)

WS37

V48M28B22EE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

275A

2400 (1090)

WS35

V48M28B33EE

500

2 at +2.5%

4 at –2.5%

DT-3

80

920E

275A

3418 (1552)

WS35

V48M28B55EE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
Additional voltage combinations are available. Contact your local Eaton sales office for assistance if the voltage you require is not included in this catalog. For other ratings or catalog numbers not
shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-17

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2

480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282B

206 (94)

WS38

V48M22T15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282B

291 (132)

WS38

V48M22T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282B

378 (172)

WS38

V48M22T45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

282B

577 (262)

WS39

V48M22T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

282B

790 (359)

WS19

V48M22T12EE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

282B

930 (422)

WS19

V48M22T49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

291A

1476 (670)

WS34

V48M22T22EE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

291A

1898 (862)

WS37

V48M22T33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

291A

2590 (1176)

WS35

V48M22T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282B

206 (94)

WS38

V48M22F15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282B

311 (141)

WS38

V48M22F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282B

418 (190)

WS38

V48M22F45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

282B

581 (264)

WS39

V48M22F75EE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

282B

829 (376)

WS19

V48M22F12EE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

282B

1022 (464)

WS19

V48M22F49EE

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

282B

1565 (711)

WS34

V48M22F22EE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

282B

1795 (815)

WS37

V48M22F33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

291A

3120 (1416)

WS35

V48M22F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

282B

278 (126)

WS38

V48M22B15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

282B

383 (174)

WS38

V48M22B30EE

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

282B

560 (254)

WS39

V48M22B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

282B

810 (368)

WS19

V48M22B75EE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

282B

959 (435)

WS19

V48M22B12EE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

282B

1287 (584)

WS34

V48M22B49EE

2

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

282B

1746 (793)

WS37

V48M22B22EE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

291A

2400 (1090)

WS35

V48M22B33EE

2
2
2

Full Capacity Taps

Notes
1 Lighting tap limited to 5% of nameplate full load capacity.
2 Weights subject to change.
Additional voltage combinations are available. Contact your local Eaton sales office for assistance if the voltage you require is not included in this catalog. For other ratings or catalog numbers not
shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-18

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2
2

480 Delta Volts to 480Y/277 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

206 (94)

WS38

V48M47T15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

281 (128)

WS38

V48M47T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

380 (173)

WS38

V48M47T45EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280B

565 (257)

WS39

V48M47T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280B

783 (355)

WS19

V48M47T12EE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280B

945 (429)

WS19

V48M47T49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

280B

1413 (642)

WS34

V48M47T22EE

300

2 at +2.5%

4 at –2.5%

DT-3

150

918A

275A

1910 (867)

WS34

V48M47T33EE

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

275A

2673 (1214)

WS35

V48M47T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

240 (109)

WS38

V48M47F15EE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

316 (143)

WS38

V48M47F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

384 (174)

WS38

V48M47F45EE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280B

670 (304)

WS39

V48M47F75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280B

853 (387)

WS19

V48M47F12EE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280B

982 (446)

WS19

V48M47F49EE

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

280B

1559 (708)

WS34

V48M47F22EE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

280B

1795 (815)

WS37

V48M47F33EE

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

275A

3120 (1416)

WS35

V48M47F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280B

271 (123)

WS38

V48M47B15EE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280B

360 (163)

WS38

V48M47B30EE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

280B

563 (256)

WS39

V48M47B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280B

773 (351)

WS19

V48M47B75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280B

954 (433)

WS19

V48M47B12EE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

280B

1330 (604)

WS34

V48M47B49EE

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

280B

1827 (829)

WS37

V48M47B22EE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

275A

2540 (1153)

WS35

V48M47B33EE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
Additional voltage combinations are available. Contact your local Eaton sales office for assistance if the voltage you require is not included in this catalog. For other ratings or catalog numbers not
shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-19

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2

600 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

231 (105)

WS38

V60M28T15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

309 (140)

WS38

V60M28T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

375 (170)

WS38

V60M28T45EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280A

572 (260)

WS39

V60M28T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280A

801 (364)

WS19

V60M28T12EE

2
2

Full Capacity Taps

Catalog Number

150

2 at +2.5%

4 at –2.5%

DT-3

150

917

280A

1013 (460)

WS34

V60M28T49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

918A

280A

1523 (691)

WS34

V60M28T22EE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

919E

280A

1697 (770)

WS35

V60M28T33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

920E

280A

2690 (1221)

WS35

V60M28T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

240 (109)

WS38

V60M28F15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

320 (145)

WS38

V60M28F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

396 (180)

WS38

V60M28F45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280A

607 (276)

WS39

V60M28F75EE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280A

960 (436)

WS19

V60M28F12EE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280A

1060 (481)

WS19

V60M28F49EE

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

280A

1500 (681)

WS34

V60M28F22EE

300

2 at +2.5%

4 at –2.5%

DT-3

115

919E

280A

1800 (817)

WS35

V60M28F33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

280A

2900 (1317)

WS35

V60M28F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280A

280 (127)

WS38

V60M28B15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280A

350 (159)

WS38

V60M28B30EE

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

280A

560 (254)

WS39

V60M28B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280A

810 (368)

WS19

V60M28B75EE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280A

950 (431)

WS19

V60M28B12EE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

280A

1430 (649)

WS34

V60M28B49EE

2

225

2 at +2.5%

4 at –2.5%

DT-3

80

919E

280A

1750 (795)

WS35

V60M28B22EE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

280A

2400 (1090)

WS35

V60M28B33EE

2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-20

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2
2

600 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282A

245 (111)

WS38

V60M22T15EE

282A

313 (142)

WS38

V60M22T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

75

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282A

403 (183)

WS38

V60M22T45EE

914F

282A

577 (262)

WS39

V60M22T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

282A

790 (359)

WS19

V60M22T12EE

150

2 at +2.5%

4 at –2.5%

DT-3

150

917

282A

1001 (454)

WS34

V60M22T49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

918A

282A

1476 (670)

WS34

V60M22T22EE

300

2 at +2.5%

4 at –2.5%

DT-3

150

919E

282A

1898 (862)

WS35

V60M22T33EE

500

2 at +2.5%

4 at –2.5%

DT-3

150

920E

282A

2590 (1176)

WS35

V60M22T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282A

206 (94)

WS38

V60M22F15EE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282A

311 (141)

WS38

V60M22F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282A

418 (190)

WS38

V60M22F45EE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

282A

581 (264)

WS39

V60M22F75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

282A

829 (376)

WS19

V60M22F12EE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

282A

1022 (464)

WS19

V60M22F49EE

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

282A

1565 (711)

WS34

V60M22F22EE

300

2 at +2.5%

4 at –2.5%

DT-3

115

919E

282A

1795 (815)

WS35

V60M22F33EE

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

282A

3120 (1416)

WS35

V60M22F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

282A

278 (126)

WS38

V60M22B15EE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

282A

383 (174)

WS38

V60M22B30EE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

282A

560 (254)

WS39

V60M22B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

282A

810 (368)

WS19

V60M22B75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

282A

959 (435)

WS19

V60M22B12EE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

282A

1287 (584)

WS34

V60M22B49EE

225

2 at +2.5%

4 at –2.5%

DT-3

80

919E

282A

1746 (793)

WS35

V60M22B22EE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

282A

2400 (1090)

WS35

V60M22B33EE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Lighting tap limited to 5% of nameplate full load capacity.
2 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-21

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2

600 Delta Volts to 480Y/277 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

206 (94)

WS38

V60M47T15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

291 (132)

WS38

V60M47T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

382 (173)

WS38

V60M47T45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280A

578 (262)

WS39

V60M47T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280A

811 (368)

WS19

V60M47T12EE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280A

934 (424)

WS19

V60M47T49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

280A

1569 (712)

WS34

V60M47T22EE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

280A

1997 (907)

WS37

V60M47T33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

275C

2641 (1199)

WS35

V60M47T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

206 (94)

WS38

V60M47F15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

311 (141)

WS38

V60M47F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

418 (190)

WS38

V60M47F45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280A

581 (264)

WS39

V60M47F75EE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280A

829 (376)

WS19

V60M47F12EE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280A

1022 (464)

WS19

V60M47F49EE

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

280A

1565 (7101)

WS34

V60M47F22EE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

280A

1795 (815)

WS37

V60M47F33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

275C

3120 (1416)

WS35

V60M47F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280A

278 (126)

WS38

V60M47B15EE

2
2
2
2
2
2

Full Capacity Taps

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280A

383 (174)

WS38

V60M47B30EE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

280A

560 (254)

WS39

V60M47B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280A

810 (368)

WS19

V60M47B75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280A

959 (435)

WS19

V60M47B12EE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

280A

1287 (584)

WS34

V60M47B49EE

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

280A

1746 (793)

WS37

V60M47B22EE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

275C

2650 (1203)

WS35

V60M47B33EE

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-22

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2
2

208 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

—

236 (107)

WS38

V29M28T15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

—

351 (159)

WS38

V29M28T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

—

453 (206)

WS38

V29M28T45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

—

687 (312)

WS39

V29M28T75CUEE

112.5

1 at +5%

2 at –5%

DT-3

150

916A

—

930 (422)

WS19

V29R28T12CUEE

150

1 at +5%

2 at –5%

DT-3

150

916A

—

1242 (564)

WS19

V29R28T49CUEE

225

1 at +5%

2 at –5%

DT-3

150

917

—

1763 (800)

WS34

V29R28T22CUEE

300

1 at +5%

2 at –5%

DT-3

150

918A

—

2300 (1044)

WS34

V29R28T33CUEE

500

1 at +5%

2 at –5%

DT-3

150

919E

—

3590 (1630)

WS35

V29R28T55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

—

265 (120)

WS38

V29M28F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

—

475 (215)

WS38

V29M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

—

475 (216)

WS38

V29M28F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

—

700 (318)

WS39

V29M28F75CUEE

112.5

1 at +5%

2 at –5%

DT-3

115

916A

—

935 (424)

WS19

V29R28F12CUEE

150

1 at +5%

2 at –5%

DT-3

115

916A

—

1274 (578)

WS19

V29R28F49CUEE

225

1 at +5%

2 at –5%

DT-3

115

917

—

1743 (791)

WS34

V29R28F22CUEE

300

1 at +5%

2 at –5%

DT-3

115

919E

—

2350 (1067)

WS35

V29R28F33CUEE

500

1 at +5%

2 at –5%

DT-3

115

920E

—

3690 (1675)

WS35

V29R28F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

—

381 (173)

WS38

V29M28B15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

—

420 (191)

WS38

V29M28B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

—

510 (232)

WS38

V29M28B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

914F

—

940 (427)

WS39

V29M28B75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

—

1300 (590)

WS19

V29M28B12CUEE

150

1 at +5%

2 at –5%

DT-3

80

918A

—

1800 (817)

WS34

V29R28B49CUEE

225

1 at +5%

2 at –5%

DT-3

80

919E

—

2400 (1090)

WS35

V29R28B22CUEE

300

1 at +5%

2 at –5%

DT-3

80

920E

—

3800 (1725)

WS35

V29R28B33CUEE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-23

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2

208 Delta Volts to 480Y/277 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342B

236 (107)

WS38

V29M47T15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342B

351 (159)

WS38

V29M47T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342B

453 (206)

WS38

V29M47T45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

342B

687 (312)

WS39

V29M47T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

351A

930 (422)

WS19

V29R47T12CUEE

2

150

1 at +5%

2 at –5%

DT-3

150

916A

351A

1242 (564)

WS19

V29R47T49CUEE

225

1 at +5%

2 at –5%

DT-3

150

917

333B

1763 (800)

WS34

V29R47T22CUEE

2

300

1 at +5%

2 at –5%

DT-3

150

918A

333B

2300 (1044

WS34

V29R47T33CUEE

2

500

1 at +5%

2 at –5%

DT-3

150

919E

333B

3590 (1630)

WS35

V29R47T55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

342B

265 (120)

WS38

V29M47F15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

342B

474.6 (215)

WS38

V29M47F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

342B

475 (216)

WS38

V29M47F45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

342B

700 (318)

WS39

V29M47F75CUEE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

342B

935 (424)

WS19

V29M47F12CUEE

150

1 at +5%

2 at –5%

DT-3

115

916A

351A

1274 (578)

WS19

V29R47F49CUEE

2

225

1 at +5%

2 at –5%

DT-3

115

917

333B

1743 (791)

WS34

V29R47F22CUEE

300

1 at +5%

2 at –5%

DT-3

115

919E

333B

2350 (1067)

WS35

V29R47F33CUEE

2

500

1 at +5%

2 at –5%

DT-3

115

920E

333B

3690 (1675)

WS35

V29R47F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

342B

381 (173)

WS38

V29M47B15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

342B

420 (191)

WS38

V29M47B30CUEE

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

342B

510 (232)

WS38

V29M47B45CUEE

75

1 at +5%

2 at –5%

DT-3

80

914F

342B

940 (427)

WS39

V29R47B75CUEE

2

112.5

1 at +5%

2 at –5%

DT-3

80

916A

342B

1300 (590)

WS19

V29R47B12CUEE

150

1 at +5%

2 at –5%

DT-3

80

918A

342B

1800 (817)

WS34

V29R47B49CUEE

2

225

1 at +5%

2 at –5%

DT-3

80

919E

333B

2400 (1090)

WS35

V29R47B22CUEE

300

1 at +5%

2 at –5%

DT-3

80

920E

333B

3800 (1725)

WS35

V29R47B33CUEE

2
2

Full Capacity Taps

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-24

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2
2

240 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280C

246 (112)

—

V24M28T15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280C

331 (150)

—

V24M28T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280C

289 (131)

—

V24M28T45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280C

664 (301)

—

V24M28T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280C

—

—

V24M28T12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280C

1130 (513)

—

V24M28T49CUEE

225

1 at +5%

2 at –5%

DT-3

150

—

—

—

—

V24R28T22CUEE

300

1 at +5%

2 at –5%

DT-3

150

—

—

—

—

V24R28T33CUEE

500

1 at +5%

2 at –5%

DT-3

150

—

—

—

—

V24R28T55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

—

—

—

V24M28F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

—

—

—

V24M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

—

—

—

—

V24M28F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280C

680 (308)

—

V24M28F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

—

—

—

—

V24M28F12CUEE

150

1 at +5%

2 at –5%

DT-3

115

—

—

—

—

V24R28F49CUEE

225

1 at +5%

2 at –5%

DT-3

115

—

—

—

—

V24R28F22CUEE

300

1 at +5%

2 at –5%

DT-3

115

—

—

—

—

V24R28F33CUEE

500

1 at +5%

2 at –5%

DT-3

115

—

—

—

—

V24R28F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280C

346 (157)

—

V24M28B15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

80

—

—

—

—

V24M28B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

—

—

—

—

V24M28B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

—

—

—

—

V24M28B75CUEE

112.5

1 at +5%

2 at –5%

DT-3

80

—

—

—

—

V24R28B12CUEE

150

1 at +5%

2 at –5%

DT-3

80

917

289A

1774 (805)

—

V24R28B49CUEE

225

1 at +5%

2 at –5%

DT-3

80

—

—

—

—

V24R28B22CUEE

300

1 at +5%

2 at –5%

DT-3

80

—

—

—

—

V24R28B33CUEE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-25

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2

240 Delta Volts to 480Y/277 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342L

341 (155)

—

V24M47T15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

342L

436 (198)

—

V24M47T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

914F

342L

685 (311)

—

V24M47T45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

342L

—

—

V24M47T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

—

—

—

—

V24M47T12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

—

—

—

—

V24M47T49CUEE

225

1 at +5%

2 at –5%

DT-3

150

—

—

—

—

V24R47T22CUEE

2

300

1 at +5%

2 at –5%

DT-3

150

—

—

—

—

V24R47T33CUEE

2

500

1 at +5%

2 at –5%

DT-3

150

—

—

—

—

V24R47T55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

—

—

—

V24M47F15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

—

—

—

—

V24M47F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

—

—

—

—

V24M47F45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

—

—

—

—

V24M47F75CUEE

2

112.5

1 at +5%

2 at –5%

DT-3

115

916A

351C

1009 (458)

—

V24R47F12CUEE

150

1 at +5%

2 at –5%

DT-3

115

—

—

—

—

V24R47F49CUEE

2

225

1 at +5%

2 at –5%

DT-3

115

—

—

—

—

V24R47F22CUEE

300

1 at +5%

2 at –5%

DT-3

115

—

—

—

—

V24R47F33CUEE

2

500

1 at +5%

2 at –5%

DT-3

115

—

—

—

—

V24R47F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

—

—

—

V24M47B15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

—

—

—

—

V24M47B30CUEE

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

—

—

—

—

V24M47B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

—

—

—

—

V24M47B75CUEE

2

112.5

1 at +5%

2 at –5%

DT-3

80

—

—

—

—

V24R47B12CUEE

150

1 at +5%

2 at –5%

DT-3

80

—

—

—

—

V24R47B49CUEE

2

225

1 at +5%

2 at –5%

DT-3

80

—

—

—

—

V24R47B22CUEE

300

1 at +5%

2 at –5%

DT-3

80

—

—

—

—

V24R47B33CUEE

2
2

Full Capacity Taps

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-26

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2
2

440 Delta Volts to 220Y/127 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280J

250 (114)

WS38

V44M31T15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280J

350 (159)

WS38

V44M31T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280J

416 (189)

WS38

V44M31T45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280J

643 (292)

WS39

V44M31T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280J

876 (398)

WS19

V44M31T12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280J

1064 (483)

WS19

V44M31T49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

280J

1545 (701)

WS34

V44M31T22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

275F

2050 (931)

WS37

V44M31T33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

275F

3681 (1671)

WS35

V44M31T55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280J

256 (116)

WS38

V44M31F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280J

337 (153)

WS38

V44M31F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280J

446 (202)

WS38

V44M31F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280J

662 (301)

WS39

V44M31F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280J

914 (415)

WS19

V44M31F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280J

1132 (514)

WS19

V44M31F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

280J

2036 (924)

WS34

V44M31F22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

275F

2325 (1056)

WS37

V44M31F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

275F

3681 (1671)

WS35

V44M31F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280J

349 (158)

WS38

V44M31B15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280J

410 (186)

WS38

V44M31B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280J

504 (229)

WS38

V44M31B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280J

818 (371)

WS19

V44M31B75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280J

1065 (484)

WS19

V44M31B12CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

917

280J

1410 (640)

WS34

V44M31B49CUEE

22

2 at +2.5%

4 at –2.5%

DT-3

80

923

280J

2030 (922)

WS37

V44M31B22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

275F

3041 (1381)

WS35

V44M31B33CUEE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-27

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2

480 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

250 (114)

WS38

V48M28T15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

350 (159)

WS38

V48M28T30CUEE

37.5

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

415 (188)

WS38

V48M28T37CUEE

2

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

416 (189)

WS38

V48M28T45CUEE

50

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280B

647 (294)

WS39

V48M28T50CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280B

643 (292)

WS39

V48M28T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280B

876 (398)

WS19

V48M28T12CUEE

Full Capacity Taps

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280B

1064 (483)

WS19

V48M28T49CUEE

2

225

2 at +2.5%

4 at –2.5%

DT-3

150

928

657B

1371 (622)

WS41

V48M28T22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

150

929

657B

1622 (736)

WS42

V48M28T33CUEE

2

500

2 at +2.5%

2 at –2.5%

DT-3

150

924

428B

3681 (1671)

WS40

V48D28T55CUEE

750

2 at +2.5%

4 at –2.5%

DT-3

150

920E

275A

4891 (2221)

WS35

V48M28T77CUEE

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

256 (116)

WS38

V48M28F15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

337 (153)

WS38

V48M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

446 (202)

WS38

V48M28F45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280B

662 (301)

WS39

V48M28F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280B

914 (415)

WS19

V48M28F12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280B

1132 (514)

WS19

V48M28F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

275A

2036 (924)

WS34

V48M28F22CUEE

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

275A

2325 (1056)

WS37

V48M28F33CUEE

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

919

275A

3681 (1671)

WS35

V48M28F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280B

349 (158)

WS38

V48M28B15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280B

410 (186)

WS38

V48M28B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280B

504 (229)

WS38

V48M28B45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280B

818 (371)

WS19

V48M28B75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280B

1065 (484)

WS19

V48M28B12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

280B

1410 (640)

WS34

V48M28B49CUEE

2

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

275A

2030 (922)

WS37

V48M28B22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

275A

3041 (1381)

WS35

V48M28B33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3

80

920E

275A

4696 (2132)

WS35

V48M28B55CUEE

2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
V2-T2-28

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2
2

480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282B

253 (115)

WS38

V48M22T15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282B

352 (160)

WS38

V48M22T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282B

415 (188)

WS38

V48M22T45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

282B

703 (319)

WS39

V48M22T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

282B

935 (424)

WS19

V48M22T12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

282B

1134 (515)

WS19

V48M22T49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

282B

1955 (888)

WS34

V48M22T22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

282B

2450 (1112)

WS37

V48M22T33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

291A

3547 (1610)

WS35

V48M22T55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282B

248 (113)

WS38

V48M22F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282B

410 (186)

WS38

V48M22F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282B

445 (202)

WS38

V48M22F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

282B

750 (341)

WS39

V48M22F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

282B

963 (437)

WS19

V48M22F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

282B

1236 (561)

WS19

V48M22F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

282B

2100 (953)

WS34

V48M22F22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

282B

2600 (1180)

WS37

V48M22F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

291A

3700 (1680)

WS35

V48M22F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

282B

301 (137)

WS38

V48M22B15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

282B

460 (209)

WS38

V48M22B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

282B

505 (229)

WS38

V48M22B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

282B

835 (379)

WS19

V48M22B75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

282B

1050 (477)

WS19

V48M22B12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

282B

2250 (1022)

WS34

V48M22B49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

291A

2900 (1317)

WS37

V48M22B22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

291A

4000 (1816)

WS35

V48M22B33CUEE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Lighting tap limited to 5% of nameplate full load capacity.
2 Weight subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-29

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2

480 Delta Volts to 480Y/277 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

257 (117)

WS38

V48M47T15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

330 (150)

WS38

V48M47T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280B

430 (195)

WS38

V48M47T45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280B

675 (306)

WS39

V48M47T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280B

900 (409)

WS19

V48M47T12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280B

1126 (511)

WS19

V48M47T49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

280B

2038 (925)

WS34

V48M47T22CUEE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

280B

2550 (1158)

WS37

V48M47T33CUEE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

275A

3412 (1549)

WS35

V48M47T55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

258 (117)

WS38

V48M47F15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

401 (182)

WS38

V48M47F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280B

455 (207)

WS38

V48M47F45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280B

678 (308)

WS39

V48M47F75CUEE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280B

676 (307)

WS19

V48M47F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280B

1249 (567)

WS19

V48M47F49CUEE

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

280B

2107 (957)

WS34

V48M47F22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

280B

2418 (1098)

WS37

V48M47F33CUEE

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

275A

3800 (1725)

WS35

V48M47F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280B

369 (168)

WS38

V48M47B15CUEE

2
2

Full Capacity Taps

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280B

423 (192)

WS38

V48M47B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280B

552 (251)

WS38

V48M47B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280B

920 (418)

WS19

V48M47B75CUEE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280B

1100 (499)

WS19

V48M47B12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

280B

1702 (773)

WS34

V48M47B49CUEE

2

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

280B

2313 (1050)

WS37

V48M47B22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

275A

3100 (1407)

WS35

V48M47B33CUEE

2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-30

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2
2

600 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

263 (119)

WS38

V60M28T15CUEE

280A

368 (167)

WS38

V60M28T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

75

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

437 (198)

WS38

V60M28T45CUEE

914F

280A

675 (307)

WS39

V60M28T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280A

920 (418)

WS19

V60M28T12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280A

1117 (507)

WS19

V60M28T49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

280A

1622 (737)

WS34

V60M28T22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

280A

2153 (977)

WS37

V60M28T33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

280A

3865 (1755)

WS35

V60M28T55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

269 (122)

WS38

V60M28F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

354 (161)

WS38

V60M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

468 (213)

WS38

V60M28F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280A

695 (316)

WS39

V60M28F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280A

960 (436)

WS19

V60M28F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280A

1189 (540)

WS19

V60M28F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

280A

2138 (971)

WS34

V60M28F22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

280A

2441 (1108)

WS37

V60M28F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

280A

3865 (1755)

WS35

V60M28F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280A

367 (166)

WS38

V60M28B15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280A

431 (195)

WS38

V60M28B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280A

529 (240)

WS38

V60M28B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280A

859 (390)

WS19

V60M28B75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280A

1118 (508)

WS19

V60M28B12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

280A

1481 (672)

WS34

V60M28B49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

280A

2132 (968)

WS37

V60M28B22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

280A

3193 (1450)

WS35

V60M28B33CUEE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-31

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2

600 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282B

263 (119)

WS38

V60M22T15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282B

368 (167)

WS38

V60M22T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

282B

437 (198)

WS38

V60M22T45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

282B

675 (307)

WS39

V60M22T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

282B

920 (418)

WS19

V60M22T12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

282B

1117 (507)

WS19

V60M22T49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

282B

1622 (737)

WS34

V60M22T22CUEE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

282B

2153 (977)

WS37

V60M22T33CUEE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

282B

3865 (1755)

WS35

V60M22T55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282B

269 (122)

WS38

V60M22F15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282B

354 (161)

WS38

V60M22F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

282B

468 (213)

WS38

V60M22F45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

282B

695 (316)

WS39

V60M22F75CUEE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

282B

960 (436)

WS19

V60M22F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

282B

1189 (540)

WS19

V60M22F49CUEE

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

282B

2138 (971)

WS34

V60M22F22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

282B

2441 (1108)

WS37

V60M22F33CUEE

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

282B

3865 (1755)

WS35

V60M22F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

282B

367 (166)

WS38

V60M22B15CUEE

2
2
2
2
2
2
2

Full Capacity Taps

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

282B

431 (195)

WS38

V60M22B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

282B

529 (240)

WS38

V60M22B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

282B

859 (390)

WS19

V60M22B75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

282B

1119 (508)

WS19

V60M22B12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

282B

1481 (672)

WS34

V60M22B49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

282B

2132 (968)

WS37

V60M22B22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

282B

3193 (1450)

WS35

V60M22B33CUEE

Notes
1 Lighting tap limited to 5% of nameplate full load capacity.
2 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-32

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2
2

600 Delta Volts to 480Y/277 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

283 (128)

WS38

V60M47T15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

363 (165)

WS38

V60M47T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

280A

473 (215)

WS38

V60M47T45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

280A

743 (337)

WS39

V60M47T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280A

990 (449)

WS19

V60M47T12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

280A

1239 (562)

WS19

V60M47T49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

280A

2242 (1018)

WS34

V60M47T22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

280A

2805 (1273)

WS37

V60M47T33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

275C

3753 (1704)

WS35

V60M47T55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

284 (129)

WS38

V60M47F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

441 (200)

WS38

V60M47F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

280A

501 (227)

WS38

V60M47F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

280A

746 (339)

WS39

V60M47F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280A

744 (338)

WS19

V60M47F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

280A

1374 (624)

WS19

V60M47F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

280A

2318 (1052)

WS34

V60M47F22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

280A

2660 (1208)

WS37

V60M47F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

275C

4180 (1898)

WS35

V60M47F55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280A

406 (184)

WS38

V60M47B15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280A

465 (211)

WS38

V60M47B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

280A

607 (276)

WS38

V60M47B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280A

1012 (459)

WS19

V60M47B75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

280A

1210 (549)

WS19

V60M47B12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

280A

1872 (850)

WS34

V60M47B49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

280A

2544 (1155)

WS37

V60M47B22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

275C

3410 (1548)

WS35

V60M47B33CUEE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-33

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings

2

208 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283A

220 (100)

WS38

V29M28E15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283A

289 (131)

WS38

V29M28E30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283A

365 (166)

WS38

V29M28E45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283A

570 (259)

WS39

V29M28E75EE

112.5

1 at +5%

2 at –5%

DT-3

150

916A

287A

930 (422)

WS19

V29R28E12EE

2

150

1 at +5%

2 at –5%

DT-3

150

916A

287A

1013 (460)

WS19

V29R28E49EE

225

1 at +5%

2 at –5%

DT-3

150

918A

287A

1639 (744)

WS34

V29R28E22EE

2

Full Capacity Taps

300

1 at +5%

2 at –5%

DT-3

150

919E

287A

1697 (770)

WS35

V29R28E33EE

500

1 at +5%

2 at –5%

DT-3

150

920E

287A

2690 (1221)

WS35

V29R28E55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283A

240 (109)

WS38

V29M28F15EEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283A

365 (166)

WS38

V29M28F30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283A

401 (182)

WS38

V29M28F45EEES

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283A

606 (275)

WS39

V29M28F75EEES

2

112.5

1 at +5%

2 at –5%

DT-3

115

916A

287A

960 (436)

WS19

V29R28F12EEES

150

1 at +5%

2 at –5%

DT-3

115

916A

287A

1060 (481)

WS19

V29R28F49EEES

225

1 at +5%

2 at –5%

DT-3

115

918A

287A

1500 (681)

WS34

V29R28F22EEES
V29R28F33EEES

2

2
2
2
2
2
2
2
2

300

1 at +5%

2 at –5%

DT-3

115

919E

287A

1800 (817)

WS35

500

1 at +5%

2 at –5%

DT-3

115

920E

287A

2900 (1317)

WS35

V29R28F55EEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283A

280 (127)

WS38

V29M28B15EEES

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283A

370 (168)

WS38

V29M28B30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283A

563 (256)

WS39

V29M28B45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283A

965 (438)

WS19

V29M28B75EEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283A

950 (431)

WS19

V29M28B12EEES

150

1 at +5%

2 at –5%

DT-3

80

918A

287A

1430 (649)

WS34

V29R28B49EEES

225

1 at +5%

2 at –5%

DT-3

80

919E

287A

1750 (795)

WS35

V29R28B22EEES

300

1 at +5%

2 at –5%

DT-3

80

920E

287A

2400 (1090)

WS35

V29R28B33EEES

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-34

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings

2
2

208 Delta Volts to 480Y/277 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345A

196 (89)

WS38

V29M47E15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345A

296 (134)

WS38

V29M47E30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345A

410 (186)

WS38

V29M47E45EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

345A

590 (268)

WS39

V29M47E75EE

112.5

1 at +5%

2 at –5%

DT-3

150

916A

315A

784 (356)

WS19

V29R47E12EE

150

1 at +5%

2 at –5%

DT-3

150

916A

315A

931 (423)

WS19

V29R47E49EE

225

1 at +5%

2 at –5%

DT-3

150

918A

315A

1550 (704)

WS34

V29R47E22EE

300

1 at +5%

2 at –5%

DT-3

150

919E

315A

2274 (1032)

WS35

V29R47E33EE

500

1 at +5%

2 at –5%

DT-3

150

919E

315A

2869 (1303)

WS35

V29R47E55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345A

215 (98)

WS38

V29M47F15EEES

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345A

380 (173)

WS38

V29M47F30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345A

400 (182)

WS38

V29M47F45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

345A

585 (266)

WS39

V29M47F75EEES

112.5

1 at +5%

2 at –5%

DT-3

115

916A

315A

800 (363)

WS19

V29R47F12EEES

150

1 at +5%

2 at –5%

DT-3

115

916A

315A

950 (431)

WS19

V29R47F49EEES

225

1 at +5%

2 at –5%

DT-3

115

918A

315A

1591 (722)

WS34

V29R47F22EEES

300

1 at +5%

2 at –5%

DT-3

115

919E

315A

2320 (1053)

WS35

V29R47F33EEES

500

1 at +5%

2 at –5%

DT-3

115

919E

315A

2950 (1339)

WS35

V29R47F55EEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

345A

300 (136)

WS38

V29M47B15EEES

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

345A

390 (177)

WS38

V29M47B30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

345A

550 (250)

WS39

V29M47B45EEES

75

1 at +5%

2 at –5%

DT-3

80

916A

315A

757 (344)

WS19

V29R47B75EEES

112.5

1 at +5%

2 at –5%

DT-3

80

916A

315A

930 (422)

WS19

V29R47B12EEES

150

1 at +5%

2 at –5%

DT-3

80

918A

315A

1550 (704)

WS34

V29R47B49EEES

225

1 at +5%

2 at –5%

DT-3

80

919E

315A

2275 (1033)

WS35

V29R47B22EEES

300

1 at +5%

2 at –5%

DT-3

80

920E

315A

2870 (1303)

WS35

V29R47B33EEES

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-35

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings

2

240 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283G

206 (94)

WS38

V24M28E15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283G

297 (135)

WS38

V24M28E30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283G

332 (151)

WS38

V24M28E45EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283G

562 (255)

WS39

V24M28E75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283G

760 (345)

WS19

V24M28E12EE

2
2
2

Full Capacity Taps

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283G

974 (442)

WS19

V24M28E49EE

225

1 at +5%

2 at –5%

DT-3

150

917

287B

1460 (663)

WS34

V24R28E22EE

300

1 at +5%

2 at –5%

DT-3

150

918A

287B

1652 (750)

WS34

V24R28E33EE

500

1 at +5%

2 at –5%

DT-3

150

919E

287B

2690 (1221)

WS35

V24R28E55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283G

240 (109)

WS38

V24M28F15EEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283G

389 (177)

WS38

V24M28F30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283G

396 (180)

WS38

V24M28F45EEES

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283G

593 (269)

WS39

V24M28F75EEES

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283G

941 (427)

WS19

V24M28F12EEES

150

1 at +5%

2 at –5%

DT-3

115

916A

287B

1060 (481)

WS19

V24R28F49EEES

2

225

1 at +5%

2 at –5%

DT-3

115

917

287B

1500 (681)

WS34

V24R28F22EEES

300

1 at +5%

2 at –5%

DT-3

115

918A

287B

1800 (817)

WS34

V24R28F33EEES

2

500

1 at +5%

2 at –5%

DT-3

115

919E

287B

2900 (1317)

WS35

V24R28F55EEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283G

280 (127)

WS38

V24M28B15EEES

2

2
2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283G

350 (159)

WS38

V24M28B30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283G

560 (254)

WS39

V24M28B45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283G

883 (401)

WS19

V24M28B75EEES

2

112.5

1 at +5%

2 at –5%

DT-3

80

916A

287B

950 (431)

WS19

V24R28B12EEES

150

1 at +5%

2 at –5%

DT-3

80

917

287B

1430 (649)

WS34

V24R28B49EEES

2

225

1 at +5%

2 at –5%

DT-3

80

918A

287B

1750 (795)

WS34

V24R28B22EEES

300

1 at +5%

2 at –5%

DT-3

80

919E

287B

2400 (1090)

WS35

V24R28B33EEES

2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-36

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings

2
2

240 Delta Volts to 480Y/277 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345C

227 (103)

WS38

V24M47E15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345C

312 (142)

WS38

V24M47E30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345C

380 (173)

WS38

V24M47E45EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

345C

573 (260)

WS39

V24M47E75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

345C

800 (363)

WS19

V24M47E12EE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

345C

885 (402)

WS19

V24M47E49EE

225

1 at +5%

2 at –5%

DT-3

150

918A

—

1612 (732)

WS34

V24R47E22EE

300

1 at +5%

2 at –5%

DT-3

150

919E

—

1652 (750)

WS35

V24R47E33EE

500

1 at +5%

2 at –5%

DT-3

150

919E

—

2695 (1224)

WS35

V24R47E55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345C

240 (109)

WS38

V24M47F15EEES

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345C

389 (177)

WS38

V24M47F30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345C

396 (180)

WS38

V24M47F45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

345C

593 (269)

WS39

V24M47F75EEES

112.5

1 at +5%

2 at –5%

DT-3

115

916A

—

941 (427)

WS19

V24R47F12EEES

150

1 at +5%

2 at –5%

DT-3

115

916A

—

1060 (481)

WS19

V24R47F49EEES

225

1 at +5%

2 at –5%

DT-3

115

918A

—

1500 (681)

WS34

V24R47F22EEES

300

1 at +5%

2 at –5%

DT-3

115

919E

—

1800 (817)

WS35

V24R47F33EEES

500

1 at +5%

2 at –5%

DT-3

115

919E

—

2900 (1317)

WS35

V24R47F55EEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

345C

280 (127)

WS38

V24M47B15EEES

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

345C

350 (159)

WS38

V24M47B30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

345C

560 (254)

WS39

V24M47B45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

345C

883 (401)

WS19

V24M47B75EEES

112.5

1 at +5%

2 at –5%

DT-3

80

916A

—

950 (431)

WS19

V24R47B12EEES

150

1 at +5%

2 at –5%

DT-3

80

918A

—

1430 (649)

WS34

V24R47B49EEES

225

1 at +5%

2 at –5%

DT-3

80

919E

—

1750 (795)

WS35

V24R47B22EEES

300

1 at +5%

2 at –5%

DT-3

80

919E

—

2400 (1090)

WS35

V24R47B33EEES

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-37

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings

2

440 Delta Volts to 220Y/127 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283Q

213 (97)

WS38

V44M31E15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283Q

300 (136)

WS38

V44M31E30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283Q

348 (158)

WS38

V44M31E45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283Q

583 (265)

WS39

V44M31E75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283Q

807 (366)

WS19

V44M31E12EE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283Q

950 (431)

WS19

V44M31E49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

283Q

1364 (619)

WS34

V44M31E22EE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

918A

283Q

1719 (780)

WS34

V44M31E33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

283Q

2560 (1162)

WS35

V44M31E55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283Q

204 (93)

WS38

V44M31F15EEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283Q

326 (148)

WS38

V44M31F30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283Q

419 (190)

WS38

V44M31F45EEES

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283Q

560 (254)

WS39

V44M31F75EEES

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283Q

805 (365)

WS19

V44M31F12EEES

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283Q

1012 (459)

WS19

V44M31F49EEES

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

283Q

1589 (721)

WS34

V44M31F22EEES

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

283Q

1782 (809)

WS37

V44M31F33EEES

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

283Q

3117 (1415)

WS35

V44M31F55EEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283Q

294 (133)

WS38

V44M31B15EEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283Q

374 (170)

WS38

V44M31B30EEES

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283Q

586 (266)

WS39

V44M31B45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283Q

807 (366)

WS19

V44M31B75EEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283Q

1005 (456)

WS19

V44M31B12EEES

2
2
2
2

Full Capacity Taps

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

283Q

1170 (531)

WS34

V44M31B49EEES

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

283Q

1764 (801)

WS37

V44M31B22EEES

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

283Q

2317 (1052)

WS35

V44M31B33EEES

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-38

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings

2
2

480 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

213 (97)

WS38

V48M28E15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

300 (136)

WS38

V48M28E30EE

37.5

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

345 (157)

WS38

V48M28E37EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

348 (158)

WS38

V48M28E45EE

50

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

550 (250)

WS39

V48M28E50EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

583 (265)

WS39

V48M28E75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

807 (366)

WS19

V48M28E12EE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

950 (431)

WS19

V48M28E49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

928

658B

1371 (622)

WS41

V48M28E22EE

300

2 at +2.5%

4 at –2.5%

DT-3

150

929

658B

1719 (780)

WS42

V48M28E33EE

500

2 at +2.5%

2 at –2.5%

DT-3

150

924

487A

2560 (1162)

WS40

V48D28E55EE

750

2 at +2.5%

4 at –2.5%

DT-3

150

920E

292A

3370 (1530)

WS35

V48M28E77EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

204 (93)

WS38

V48M28F15EEES

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

326 (148)

WS38

V48M28F30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

419 (190)

WS38

V48M28F45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283B

560 (254)

WS39

V48M28F75EEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

805 (365)

WS19

V48M28F12EEES

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

1012 (459)

WS19

V48M28F49EEES

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

283B

1589 (721)

WS34

V48M28F22EEES

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

283B

1782 (809)

WS37

V48M28F33EEES

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

292A

3117 (1415)

WS35

V48M28F55EEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

294 (133)

WS38

V48M28B15EEES

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

374 (170)

WS38

V48M28B30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283B

586 (266)

WS39

V48M28B45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

807 (366)

WS19

V48M28B75EEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

1005 (456)

WS19

V48M28B12EEES

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

283B

1170 (531)

WS34

V48M28B49EEES

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

283B

1764 (801)

WS37

V48M28B22EEES

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

292A

2317 (1052)

WS35

V48M28B33EEES

500

2 at +2.5%

4 at –2.5%

DT-3

80

920E

292A

3379 (1534)

WS35

V48M28B55EEES

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-39

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings

2

480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

284B

220 (100)

WS38

V48M22E15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

284B

293 (133)

WS38

V48M22E30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

284B

348 (158)

WS38

V48M22E45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

284B

554 (252)

WS39

V48M22E75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

284B

820 (372)

WS19

V48M22E12EE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

284B

940 (427)

WS19

V48M22E49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

284B

1421 (645)

WS34

V48M22E22EE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

284B

1787 (811)

WS37

V48M22E33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

293A

2504 (1137)

WS35

V48M22E55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

284B

231 (105)

WS38

V48M22F15EEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

284B

326 (148)

WS38

V48M22F30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

284B

397 (180)

WS38

V48M22F45EEES

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

284B

615 (279)

WS39

V48M22F75EEES

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

284B

805 (365)

WS19

V48M22F12EEES

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

284B

1012 (459)

WS19

V48M22F49EEES

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

284B

1589 (721)

WS34

V48M22F22EEES

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

284B

1782 (809)

WS37

V48M22F33EEES

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

293A

3117 (1415)

WS35

V48M22F55EEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

284B

294 (133)

WS38

V48M22B15EEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

284B

374 (170)

WS38

V48M22B30EEES

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

284B

586 (266)

WS39

V48M22B45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

284B

807 (366)

WS19

V48M22B75EEES

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

284B

1005 (456)

WS19

V48M22B12EEES

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

284B

1170 (531)

WS34

V48M22B49EEES

2

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

284B

1764 (801)

WS37

V48M22B22EEES

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

293A

2317 (1052)

WS35

V48M22B33EEES

2
2
2

Full Capacity Taps

Notes
1 Lighting tap limited to 5% of nameplate full load capacity.
2 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-40

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Aluminum Windings

2
2

480 Delta Volts to 480Y/277 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

220 (100)

WS38

V48M47E15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

293 (133)

WS38

V48M47E30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

398 (181)

WS38

V48M47E45EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

554 (252)

WS39

V48M47E75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

820 (372)

WS19

V48M47E12EE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

940 (427)

WS19

V48M47E49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

283B

1421 (645)

WS34

V48M47E22EE

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

283B

1735 (788)

WS34

V48M47E33EE

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

292A

2504 (1137)

WS35

V48M47E55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

231 (105)

WS38

V48M47F15EEES

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

326 (148)

WS38

V48M47F30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

397 (180)

WS38

V48M47F45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283B

615 (279)

WS39

V48M47F75EEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

805 (365)

WS19

V48M47F12EEES

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

1012 (459)

WS19

V48M47F49EEES

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

283B

1589 (721)

WS34

V48M47F22EEES

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

283B

1782 (809)

WS37

V48M47F33EEES

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

292A

3117 (1415)

WS35

V48M47F55EEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

294 (133)

WS38

V48M47B15EEES

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

374 (170)

WS38

V48M47B30EEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283B

586 (266)

WS39

V48M47B45EEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

807 (366)

WS19

V48M47B75EEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

1005 (456)

WS19

V48M47B12EEES

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

283B

1170 (531)

WS34

V48M47B49EEES

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

283B

1764 (801)

WS37

V48M47B22EEES

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

292A

2317 (1052)

WS35

V48M47B33EEES

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-41

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings

2

208 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283A

262 (119)

WS38

V29M28E15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283A

351 (159)

WS38

V29M28E30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283A

453 (206)

WS38

V29M28E45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283A

526 (239)

WS39

V29M28E75CUEE

112.5

1 at +5%

2 at –5%

DT-3

150

916A

287A

930 (422)

WS19

V29R28E12CUEE

2

150

1 at +5%

2 at –5%

DT-3

150

916A

287A

1242 (564)

WS19

V29R28E49CUEE

225

1 at +5%

2 at –5%

DT-3

150

917

287A

1900 (863)

WS34

V29R28E22CUEE

2

300

1 at +5%

2 at –5%

DT-3

150

918A

287A

2300 (1044)

WS34

V29R28E33CUEE

2

500

1 at +5%

2 at –5%

DT-3

150

919E

287A

3590 (1630)

WS35

V29R28E55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283A

266 (121)

WS38

V29M28F15CUEEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283A

476 (215)

WS38

V29M28F30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283A

475 (216)

WS38

V29M28F45CUEEES

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

287A

700 (318)

WS39

V29M28F75CUEEES

2

112.5

1 at +5%

2 at –5%

DT-3

115

916A

287A

935 (424)

WS19

V29R28F12CUEEES

150

1 at +5%

2 at –5%

DT-3

115

916A

287A

1274 (578)

WS19

V29R28F49CUEEES

2

225

1 at +5%

2 at –5%

DT-3

115

917

287A

1743 (791)

WS34

V29R28F22CUEEES

300

1 at +5%

2 at –5%

DT-3

115

919E

287A

2350 (1067)

WS35

V29R28F33CUEEES

2

500

1 at +5%

2 at –5%

DT-3

115

920E

287A

3690 (1675)

WS35

V29R28F55CUEEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283A

381 (173)

WS38

V29M28B15CUEEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283A

420 (191)

WS38

V29M28B30CUEEES

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283A

510 (232)

WS38

V29M28B45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283A

940 (427)

WS39

V29M28B75CUEEES

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283A

1300 (590)

WS19

V29M28B12CUEEES

150

1 at +5%

2 at –5%

DT-3

80

918A

287A

1800 (817)

WS34

V29R28B49CUEEES

2

225

1 at +5%

2 at –5%

DT-3

80

919E

287A

2400 (1090)

WS35

V29R28B22CUEEES

300

1 at +5%

2 at –5%

DT-3

80

920E

287A

3800 (1725)

WS35

V29R28B33CUEEES

2
2

Full Capacity Taps

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-42

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings

2
2

208 Delta Volts to 480Y/277 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345A

236 (107)

WS38

V29M47E15CUEE

345A

351 (159)

WS38

V29M47E30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

75

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345A

453 (206)

WS38

V29M47E45CUEE

914F

345A

687 (312)

WS39

V29M47E75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

315A

930 (422)

WS19

V29R47E12CUEE

150

1 at +5%

2 at –5%

DT-3

150

916A

315A

1242 (564)

WS19

V29R47E49CUEE

225

1 at +5%

2 at –5%

DT-3

150

917

315A

1763 (800)

WS34

V29R47E22CUEE

2
2
2
2
2
2

300

1 at +5%

2 at –5%

DT-3

150

918A

315A

2300 (1044)

WS34

V29R47E33CUEE

500

1 at +5%

2 at –5%

DT-3

150

919E

315A

3590 (1630)

WS35

V29R47E55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345A

265 (120)

WS38

V29M47F15CUEEES

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345A

475 (215)

WS38

V29M47F30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345A

475 (216)

WS38

V29M47F45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

345A

768 (349)

WS39

V29M47F75CUEEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

345A

935 (424)

WS19

V29M47F12CUEEES

150

1 at +5%

2 at –5%

DT-3

115

916A

315A

1274 (578)

WS19

V29R47F49CUEEES

225

1 at +5%

2 at –5%

DT-3

115

917

315A

1743 (791)

WS34

V29R47F22CUEEES

300

1 at +5%

2 at –5%

DT-3

115

919E

315A

2350 (1067)

WS35

V29R47F33CUEEES

500

1 at +5%

2 at –5%

DT-3

115

920E

315A

3690 (1675)

WS35

V29R47F55CUEEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

345A

381 (173)

WS38

V29M47B15CUEEES

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

345A

420 (191)

WS38

V29M47B30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

345A

510 (232)

WS38

V29M47B45CUEEES

75

1 at +5%

2 at –5%

DT-3

80

914F

315A

940 (427)

WS39

V29R47B75CUEEES

112.5

1 at +5%

2 at –5%

DT-3

80

916A

315A

1300 (590)

WS19

V29R47B12CUEEES

150

1 at +5%

2 at –5%

DT-3

80

918A

315A

1800 (817)

WS34

V29R47B49CUEEES

225

1at +5%

2 at –5%

DT-3

80

919E

315A

2400 (1090)

WS35

V29R47B22CUEEES

300

1 at +5%

2 at –5%

DT-3

80

920E

315A

3800 (1725)

WS35

V29R47B33CUEEES

2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-43

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings

2

240 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283G

262 (119)

WS38

V24M28E15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283G

351 (159)

WS38

V24M28E30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283G

453 (206)

WS38

V24M28E45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283G

526 (239)

WS39

V24M28E75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283G

930 (422)

WS19

V24M28E12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283G

1242 (564)

WS19

V24M28E49CUEE

225

1 at +5%

2 at –5%

DT-3

150

917

287B

1900 (863)

WS34

V24R28E22CUEE

2

300

1 at +5%

2 at –5%

DT-3

150

918A

287B

2300 (1044)

WS34

V24R28E33CUEE

2

500

1 at +5%

2 at –5%

DT-3

150

919E

287B

3590 (1630)

WS35

V24R28E55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283G

266 (121)

WS38

V24M28F15CUEEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283G

475 (215)

WS38

V24M28F30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283G

475 (216)

WS38

V24M28F45CUEEES

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283G

700 (318)

WS39

V24M28F75CUEEES

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283G

935 (424)

WS19

V24M28F12CUEEES

150

1 at +5%

2 at –5%

DT-3

115

916A

287B

1274 (578)

WS19

V24R28F49CUEEES

2

225

1 at +5%

2 at –5%

DT-3

115

917

287B

1743 (791)

WS34

V24R28F22CUEEES

300

1 at +5%

2 at –5%

DT-3

115

918A

287B

2350 (1067)

WS34

V24R28F33CUEEES

2

500

1 at +5%

2 at –5%

DT-3

115

919E

287B

3690 (1675)

WS35

V24R28F55CUEEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283G

381 (173)

WS38

V24M28B15CUEEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283G

420 (191)

WS38

V24M28B30CUEEES

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283G

510 (232)

WS39

V24M28B45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283G

940 (427)

WS19

V24M28B75CUEEES

112.5

1 at +5%

2 at –5%

DT-3

80

916A

287B

1300 (590)

WS19

V24R28B12CUEEES

2
2
2
2

Full Capacity Taps

150

1 at +5%

2 at –5%

DT-3

80

917

287B

1800 (817)

WS34

V24R28B49CUEEES

225

1 at +5%

2 at –5%

DT-3

80

918A

287B

2400 (1090)

WS34

V24R28B22CUEEES

300

1 at +5%

2 at –5%

DT-3

80

919E

287B

3800 (1725)

WS35

V24R28B33CUEEES

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-44

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings

2
2

240 Delta Volts to 480Y/277 Volts
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345C

262 (119)

WS38

V24M47E15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345C

351 (159)

WS38

V24M47E30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

345C

453 (206)

WS38

V24M47E45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

345C

526 (239)

WS39

V24M47E75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

345C

930 (422)

WS19

V24M47E12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

345C

1242 (564)

WS19

V24M47E49CUEE

225

1 at +5%

2 at –5%

DT-3

150

918A

—

1900 (863)

WS34

V24R47E22CUEE

300

1 at +5%

2 at –5%

DT-3

150

919E

—

2300 (1044)

WS35

V24R47E33CUEE

500

1 at +5%

2 at –5%

DT-3

150

919E

—

3590 (1630)

WS35

V24R47E55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345C

266 (121)

WS38

V24M47F15CUEEES

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345C

475 (215)

WS38

V24M47F30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

345C

475 (216)

WS38

V24M47F45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

345C

700 (318)

WS39

V24M47F75CUEEES

112.5

1 at +5%

2 at –5%

DT-3

115

916A

—

935 (424)

WS19

V24R47F12CUEEES

150

1 at +5%

2 at –5%

DT-3

115

916A

—

1274 (578)

WS19

V24R47F49CUEEES

225

1 at +5%

2 at –5%

DT-3

115

918A

—

1743 (791)

WS34

V24R47F22CUEEES

300

1 at +5%

2 at –5%

DT-3

115

919E

—

2350 (1067)

WS35

V24R47F33CUEEES

500

1 at +5%

2 at –5%

DT-3

115

919E

—

3690 (1675)

WS35

V24R47F55CUEEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

345C

381 (173)

WS38

V24M47B15CUEEES

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

345C

420 (191)

WS38

V24M47B30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

345C

510 (232)

WS39

V24M47B45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

345C

940 (427)

WS19

V24M47B75CUEEES

112.5

1 at +5%

2 at –5%

DT-3

80

916A

—

1300 (590)

WS19

V24R47B12CUEEES

150

1 at +5%

2 at –5%

DT-3

80

918A

—

1800 (817)

WS34

V24R47B49CUEEES

225

1 at +5%

2 at –5%

DT-3

80

919E

—

2400 (1090)

WS35

V24R47B22CUEEES

300

1 at +5%

2 at –5%

DT-3

80

919E

—

3800 (1725)

WS35

V24R47B33CUEEES

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-45

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings

2

440 Delta Volts to 220Y/127 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283Q

251 (114)

WS38

V44M31E15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283Q

353 (160)

WS38

V44M31E30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283Q

421 (191)

WS38

V44M31E45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283Q

648 (294)

WS39

V44M31E75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283Q

910 (413)

WS19

V44M31E12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283Q

1052 (478)

WS19

V44M31E49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

283Q

1548 (703)

WS34

V44M31E22CUEE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

283Q

2029 (921)

WS37

V44M31E33CUEE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

283Q

3680 (1671)

WS35

V44M31E55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283Q

239 (109)

WS38

V44M31F15CUEEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283Q

363 (165)

WS38

V44M31F30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283Q

442 (201)

WS38

V44M31F45CUEEES

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283Q

676 (307)

WS39

V44M31F75CUEEES

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283Q

926 (420)

WS19

V44M31F12CUEEES

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283Q

1246 (566)

WS19

V44M31F49CUEEES

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

283Q

1692 (768)

WS34

V44M31F22CUEEES

500

2 at +2.5%

4 at –2.5%

DT-3

115

923

283Q

2325 (1056)

WS37

V44M31F33CUEEES

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

283Q

3646 (1655)

WS35

V44M31F55CUEEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283Q

331 (150)

WS38

V44M31B15CUEEES

2
2

Full Capacity Taps

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283Q

390 (177)

WS38

V44M31B30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283Q

545 (247)

WS38

V44M31B45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283Q

956 (434)

WS19

V44M31B75CUEEES

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283Q

1045 (474)

WS19

V44M31B12CUEEES

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

283Q

1425 (647)

WS34

V44M31B49CUEEES

2

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

283Q

2082 (945)

WS37

V44M31B22CUEEES

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

283Q

3283 (1490)

WS35

V44M31B33CUEEES

2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
V2-T2-46

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings

2
2

480 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

251 (114)

WS38

V48M28E15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

353 (160)

WS38

V48M28E30CUEE

37.5

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

415 (188)

WS38

V48M28E37CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

421 (191)

WS38

V48M28E45CUEE

50

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

647 (294)

WS39

V48M28E50CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

648 (294)

WS39

V48M28E75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

910 (413)

WS19

V48M28E12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

1052 (478)

WS19

V48M28E49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

928

658B

1548 (703)

WS41

V48M28E22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

150

929

658B

1622 (737)

WS42

V48M28E33CUEE

2
2
2
2
2
2
2

500

2 at +2.5%

2 at –2.5%

DT-3

150

924

292A

3680 (1671)

WS40

V48D28E55CUEE

750

2 at +2.5%

4 at –2.5%

DT-3

150

920E

292A

4890 (2220)

WS35

V48M28E77CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

239 (109)

WS38

V48M28F15CUEEES

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

363 (165)

WS38

V48M28F30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

442 (201)

WS38

V48M28F45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283B

676 (307)

WS39

V48M28F75CUEEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

926 (420)

WS19

V48M28F12CUEEES

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

1246 (566)

WS19

V48M28F49CUEEES

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

292A

1692 (768)

WS34

V48M28F22CUEEES

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

292A

2325 (1056)

WS37

V48M28F33CUEEES

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

292A

3646 (1655)

WS35

V48M28F55CUEEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

331 (150)

WS38

V48M28B15CUEEES

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

390 (177)

WS38

V48M28B30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

545 (248)

WS38

V48M28B45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

956 (434)

WS19

V48M28B75CUEEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

1045 (474)

WS19

V48M28B12CUEEES

2

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

292A

1425 (647)

WS34

V48M28B49CUEEES

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

292A

2082 (945)

WS37

V48M28B22CUEEES

300

2 at +2.5%

4 at– 2.5%

DT-3

80

919E

292A

3283 (1490)

WS35

V48M28B33CUEEES

500

2 at +2.5%

4 at –2.5%

DT-3

80

920E

292A

4800 (2179)

WS35

V48M28B55CUEEES

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-47

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings

2

480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 1

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 2

Weathershield

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

284B

253 (115)

WS38

V48M22E15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

284B

352 (160)

WS38

V48M22E30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

284B

415 (188)

WS38

V48M22E45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

284B

703 (319)

WS39

V48M22E75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

284B

935 (424)

WS19

V48M22E12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

284B

1134 (515)

WS19

V48M22E49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

284B

1955 (888)

WS34

V48M22E22CUEE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

284B

2450 (1112)

WS37

V48M22E33CUEE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

293A

3547 (1610)

WS35

V48M22E55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

284B

248 (113)

WS38

V48M22F15CUEEES

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

284B

410 (186)

WS38

V48M22F30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

284B

445 (202)

WS38

V48M22F45CUEEES

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

284B

750 (341)

WS39

V48M22F75CUEEES

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

284B

963 (437)

WS19

V48M22F12CUEEES

150

2 at +2.5%

4 at –2.5%

DT-3

115

916A

284B

1236 (561)

WS19

V48M22F49CUEEES

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

284B

2100 (953)

WS34

V48M22F22CUEEES

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

284B

2600 (1180)

WS37

V48M22F33CUEEES

2

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

293A

3700 (1680)

WS35

V48M22F55CUEEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

284B

247 (113)

WS38

V48M22B15CUEEES

2
2

Full Capacity Taps

Catalog Number

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

284B

460 (209)

WS38

V48M22B30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

284B

505 (229)

WS38

V48M22B45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

284B

835 (379)

WS19

V48M22B75CUEEES

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

284B

1050 (477)

WS19

V48M22B12CUEEES

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

284B

2250 (1022)

WS34

V48M22B49CUEEES

2

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

284B

2900 (1317)

WS37

V48M22B22CUEEES

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

293A

4000 (1816)

WS35

V48M22B33CUEEES

2
2
2

Notes
1 Lighting tap limited to 5% of nameplate full load capacity.
2 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-48

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Electrostatically Shielded—Copper Windings

2
2

480 Delta Volts to 480Y/277 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

340 (154)

WS38

V48M47E15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

340 (154)

WS38

V48M47E30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

430 (195)

WS38

V48M47E45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

677 (307)

WS39

V48M47E75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

900 (409)

WS19

V48M47E12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

1132 (514)

WS19

V48M47E49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

283B

1550 (704)

WS34

V48M47E22CUEE

2
2
2
2
2
2

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

283B

2550 (1158)

WS37

V48M47E33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3

150

919E

292A

3412 (1549)

WS35

V48M47E55CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

258 (117)

WS38

V48M47F15CUEEES

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

426 (193)

WS38

V48M47F30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

446 (202)

WS38

V48M47F45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283B

666 (302)

WS39

V48M47F75CUEEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

912 (414)

WS19

V48M47F12CUEEES

150

2 at +2.5%

4 at –2.5%

DT-3

115

917

283B

1600 (726)

WS19

V48M47F49CUEEES

225

2 at +2.5%

4 at –2.5%

DT-3

115

917

283B

2107 (957)

WS34

V48M47F22CUEEES

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

283B

2418 (1098)

WS37

V48M47F33CUEEES

500

2 at +2.5%

4 at –2.5%

DT-3

115

919E

292A

3800 (1725)

WS35

V48M47F55CUEEES

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

369 (168)

WS38

V48M47B15CUEEES

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

430 (195)

WS38

V48M47B30CUEEES

45

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

552 (251)

WS38

V48M47B45CUEEES

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

920 (418)

WS19

V48M47B75CUEEES

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

1210 (549)

WS19

V48M47B12CUEEES

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

283B

1702 (773)

WS34

V48M47B49CUEEES

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

283B

2313 (1050)

WS37

V48M47B22CUEEES

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

292A

3100 (1407)

WS35

V48M47B22CUEEES

2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-49

2.1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Accessories
Please refer to Section 2.7 Page V2-T2-191.

Technical Data and Specifications
Frequency

Enclosures

Sound Levels

Eaton standard dry-type
distribution transformers are
designed for 60 Hz operation.
Transformers required for
other frequencies are
available and must be
specifically designed.

Eaton’s ventilated
transformers, Types DS-3 and
DT-3, use a NEMA 2 rated
(drip-proof) enclosure as
standard, and are rated
NEMA 3R with the addition
of weathershields.

Overload Capability

Winding Terminations

Short-term overload is
designed into transformers as
required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250 for
additional limitations.

Primary and secondary
windings are terminated
in the wiring compartment.
Encapsulated units have
copper leads or stabs
brought out for connections.
Ventilated transformers have
leads brought out to terminals
that are pre-drilled to accept
Cu/Al lugs. Aluminum-wound
transformers have aluminum
terminals; copper-wound
models have copper
terminals. Lugs are not
supplied with these
transformers. Eaton
recommends external cables
be rated 90°C (sized at 75°C
ampacity) for encapsulated
designs and 75°C for
ventilated designs.

All Eaton 600 volt class
general-purpose dry-type
distribution transformers are
designed to meet NEMA
ST-20 sound levels listed
here. These are the sound
levels measured in a
soundproof environment.
Actual sound levels
measured at an installation

Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.

Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:
Insulation System
Classification

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

2

40°C

80°C

30°C

150°C

2

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

2

40°C

150°C

30°C

220°C

2

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.

2

2
2
2

Average Sound Levels
NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

V2-T2-50

Encapsulated
(up to 1.2 kV)

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

50.01 to 75.00

50

53

55

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

Series-Multiple Windings

300.01 to 500.00

60

63

59

Series-multiple windings
consist of two similar coils in
each winding that can be
connected in series or parallel
(multiple). Transformers with
series-multiple windings are
designated with an “x” or
“/” between the voltage
ratings, such as voltages of
“120/240” or “240 x 480.”
If the series-multiple winding
is designated by an “x,” the
winding can be connected
only for a series or parallel.
With the “/” designation,
a mid-point also becomes
available in addition to the
series or parallel connection.
As an example, a 120 x 240
winding can be connected
for either 120 (parallel) or
240 (series), but a 120/240
winding can be connected for
120 (parallel), or 240 (series),
or 240 with a 120 mid-point.

500.01 to 700.00

62

65

61

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including
stainless steel), refer to Eaton.

For additional information,
please refer to Section 2.7
Page V2-T2-191.

2

will likely be higher (as much
as 15 dB greater) due to
electrical connections and
environmental conditions.
Lower sound levels are
available and should be
specified when the
transformer is going to be
installed in an area where
sound may be a concern.

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
NEMA TP-1 Energy-Efficient Transformers

2.1

K-Factor
Product Description
A common industry term for
the amount of harmonics
produced by a given load is
the K-factor. The larger the
K-factor, the more harmonics
are present. Linear loads, for
example, have a K-factor of 1.
Transformers may carry a
K-factor rating to define the
transformer’s ability to
withstand the additional
heating generated by
harmonic currents.
Calculating the K-Factor
All nonlinear waveforms
can be broken down
mathematically into a
fundamental frequency
and its harmonics. IEEE
C57.110 establishes a direct
relationship between these
harmonics and transformer
heating. Underwriters
Laboratories has established
a similar relationship, the
K-factor, which is derived by
summing the square of the
percentage current at a
given harmonic level
multiplied by the square
of the harmonic order.
K = ²(Ih)2(h)2
Ih = Percent Current at
Harmonic h
h = Harmonic Order,
i.e., 3rd, 5th, 7th
For example, a load that is
90% of the fundamental,
30% of the third harmonic,
and 20% of the fifth harmonic
would yield (.9)2(1)2 + (.3)2(3)2
+ (.2)2(5)2 or a K-factor of
2.62. This load would require
an Eaton KT-4 transformer
with a K-factor rating of 4.
Transformers that carry a
K-factor rating define the

transformer’s ability to
withstand a given harmonic
load while operating within
the transformer’s insulation
class.
An analysis of harmonic loads
and a calculation of the
K-factor must be made to
properly apply transformers
in any building or facility.
Note that the calculated
K-factor is not constant
because nonlinear loads
change throughout the day
as equipment and lighting is
turned off and on. These
harmonic loads also change
over the life of the building or
facility as equipment is added
or removed.
Harmonic Currents
Harmonic currents are found
in nonlinear loads. These
currents are generated by
various types of equipment
including switching mode
power supplies that abruptly
switch current on and off
during each line cycle.
Switching mode power
supplies or diode-capacitor
power supplies convert
AC line voltage to low
voltage DC. This process
is accomplished by charging
capacitors during each line
cycle with narrow pluses
of current that are timecoincident with line voltage
peaks. Examples of this
equipment include electronic
ballasts for fluorescent
lighting, personal computers,
printers, fax machines,
electronic and medical test
equipment, uninterruptible
power supplies, and
solid-state motor drives.

Features, Benefits
and Functions
●
●

●

●

●

●

600 volt class standard
Three-phase, 480 delta–
208Y/120 volt standard
Single-phase, 240 x 480
volt–120/240 volt standard
150°C rise standard, 80°C
and 115ºC available
Three-phase neutrals sized
for 200% of rated current
Electrostatic shield

Note: Electrostatic shields
do not reduce harmonic levels.
However, because of the nature
of switching mode loads, these
shields do reduce transient noise
in the system, which may affect
sensitive computer loads.
●

●
●

Aluminum windings
(copper optional)
Class 220°C insulation
Reduced core flux density

Note: Reduced core flux prevents
the core from saturation and
overheating due to voltage
distortions caused by harmonic
currents.
●

●

●
●

●

●

Indoor enclosures
(weathershields optional,
for outdoor applications)
Coils designed to minimize
stray losses
K4, K13 standard
K9, K20, K30, K40,
K50 optional
Low sound level (–3 dB,
–5 dB) available as options
Available with NEMA TP-1
efficiency levels

Standards and Certifications
●

UL listed

2
2
2
2

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards. All
600 volt class transformers
are UL listed unless
otherwise noted.
Seismically Qualified
Eaton manufactured dry-type
distribution transformers are
seismically qualified and
exceed requirements of the
Uniform Building Code (UBC),
International Building Code
(IBC) and California Code
Title 24.

Catalog Number Selection
Please refer to Section 2.7
Page V2-T2-187.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note: Nonlinear is synonymous
with the term non-sinusoidal.

2
2

Harmonic Currents Found in Nonlinear Loads Cause Wave
Shape Distortion and Create Added Stresses on Transformers

2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-51

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

2

Product Selection

2

Single-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2

K-4 240 x 480 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2

2

DS-3

150

816

261A

222 (101)

WS11

HT20P11S15EE

25

2

2

DS-3

150

818

261A

360 (163)

WS11

HT20P11S25EE

2

37.5

2

2

DS-3

150

818

261A

365 (166)

WS11

HT20P11S37EE

2

2

2

50

DS-3

150

819

261A

560 (254)

WS16

HT20P11S50EE

75

2

2

DS-3

150

820

261A

688 (312)

WS16

HT20P11S75EE

2

15

2

2

DS-3

115

816

261A

229 (104)

WS11

HT20P11F15EE

25

2

2

DS-3

115

818

261A

365 (166)

WS11

HT20P11F25EE

2

37.5

2

2

DS-3

115

818

261A

380 (172)

WS11

HT20P11F37EE

50

2

2

DS-3

115

819

261A

580 (263)

WS16

HT20P11F50EE

2

75

2

2

DS-3

115

820

261A

700 (318)

WS16

HT20P11F75EE

2

15

2

2

DS-3

80

816

261A

—

WS11

HT20P11B15EE

25

2

2

DS-3

80

818

261A

—

WS11

HT20P11B25EE

2

37.5

2

2

DS-3

80

819

261A

—

WS16

HT20P11B37EE

50

2

2

DS-3

80

820

261A

—

WS16

HT20P11B50EE

2

75

2

2

DS-3

80

821

261A

976 (443)

WS13

HT20P11B75EE

2

Full Capacity Taps

2

K-13 240 x 480 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2

2

DS-3

150

816

261A

247 (112)

WS11

NT20P11S15EE

2

25

2

2

DS-3

150

818

261A

370 (168)

WS11

NT20P11S25EE

37.5

2

2

DS-3

150

819

261A

580 (263)

WS16

NT20P11S37EE

2

50

2

2

DS-3

150

820

261A

700 (318)

WS16

NT20P11S50EE

75

2

2

DS-3

150

821

261A

924 (419)

WS13

NT20P11S75EE

2

15

2

2

DS-3

115

816

261A

260 (118)

WS11

NT20P11F15EE

2

2

2

25

DS-3

115

818

261A

380 (172)

WS11

NT20P11F25EE

37.5

2

2

DS-3

115

819

261A

590 (268)

WS16

NT20P11F37EE

2

50

2

2

DS-3

115

820

261A

700 (318)

WS16

NT20P11F50EE

75

2

2

DS-3

115

821

261A

970 (440)

WS13

NT20P11F75EE

2

15

2

2

DS-3

80

816

261A

—

WS11

NT20P11B15EE

25

2

2

DS-3

80

818

261A

—

WS11

NT20P11B25EE

2

37.5

2

2

DS-3

80

819

261A

—

WS16

NT20P11B37EE

2

50

2

2

DS-3

80

820

261A

—

WS16

NT20P11B50EE

75

2

2

DS-3

80

821

261A

—

WS13

NT20P11B75EE

2

2
2

Full Capacity Taps

Notes
1 Weights subject to change.
2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
V2-T2-52

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2
2

K-4 480 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

206 (94)

WS38

H48M28T15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

311 (141)

WS38

H48M28T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

400 (182)

WS38

H48M28T45EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

547 (248)

WS39

H48M28T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

800 (363)

WS19

H48M28T12EE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

1010 (459)

WS19

H48M28T49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

918A

283B

1680 (763)

WS34

H48M28T22EE

300

2 at +2.5%

4 at –2.5%

DT-3

150

919E

292A

2122 (963)

WS35

H48M28T33EE

500

2 at +2.5%

4 at –2.5%

DT-3

150

920E

292A

3201 (1453)

WS35

H48M28T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

307 (139)

WS38

H48M28F15EE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

313 (142)

WS38

H48M28F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

400 (182)

WS38

H48M28F45EE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283B

587 (266)

WS39

H48M28F75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

947 (430)

WS19

H48M28F12EE

150

2 at +2.5%

4 at –2.5%

DT-3

115

917

283B

1243 (564)

WS34

H48M28F49EE

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

283B

1680 (763)

WS34

H48M28F22EE

300

2 at +2.5%

4 at –2.5%

DT-3

115

919E

292A

2480 (1126)

WS35

H48M28F33EE

500

2 at +2.5%

4 at –2.5%

DT-3

115

920E

292A

3280 (1489)

WS35

H48M28F55EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

378 (172)

WS38

H48M28B15EE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

365 (166)

WS38

H48M28B30EE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283B

550 (250)

WS39

H48M28B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

774 (351)

WS19

H48M28B75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

283B

1380 (627)

WS34

H48M28B12EE

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

283B

1604 (728)

WS34

H48M28B49EE

225

2 at +2.5%

4 at –2.5%

DT-3

80

919E

292A

2336 (1061)

WS35

H48M28B22EE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

292A

2689 (1221)

WS35

H48M28B33EE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-53

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2

K-13 480 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

271 (123)

WS38

N48M28T15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

365 (166)

WS38

N48M28T30EE

2

45

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

545 (247)

WS39

N48M28T45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

812 (369)

WS19

N48M28T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

920 (418)

WS19

N48M28T12EE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

917

283B

1221 (554)

WS34

N48M28T49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

923

283B

1960 (890)

WS37

N48M28T22EE

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

919E

292A

2358 (1071)

WS35

N48M28T33EE

2

500

2 at +2.5%

4 at –2.5%

DT-3

150

922

292A

4799 (2179)

WS36

N48M28T55EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

332 (151)

WS38

N48M28F15EE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

390 (177)

WS38

N48M28F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283B

548 (249)

WS39

N48M28F45EE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

808 (367)

WS19

N48M28F75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

990 (449)

WS19

N48M28F12EE

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

292A

1769 (803)

WS34

N48M28F49EE

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

919E

292A

2306 (1047)

WS35

N48M28F22EE

300

2 at +2.5%

4 at –2.5%

DT-3

115

919E

292A

3291 (1494)

WS35

N48M28F33EE

2

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

315 (143)

WS38

N48M28B15EE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

408 (185)

WS38

N48M28B30EE

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283B

555 (252)

WS39

N48M28B45EE

2

Full Capacity Taps

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

838 (380)

WS19

N48M28B75EE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

283B

1367 (621)

WS34

N48M28B12EE

2

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

292A

1607 (730)

WS34

N48M28B49EE

225

2 at +2.5%

4 at –2.5%

DT-3

80

919E

292A

2582 (1172)

WS35

N48M28B22EE

300

2 at +2.5%

4 at –2.5%

DT-3

80

920E

292A

3228 (1466)

WS35

N48M28B33EE

2
2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
V2-T2-54

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Aluminum Windings

2
2

K-20 480 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

295 (134)

WS38

G48M28T15EE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

367 (167)

WS38

G48M28T30EE

45

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

563 (256)

WS39

G48M28T45EE

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

808 (367)

WS19

G48M28T75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

283B

1379 (626)

WS34

G48M28T12EE

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

292A

1559 (708)

WS34

G48M28T49EE

225

2 at +2.5%

4 at –2.5%

DT-3

150

919E

292A

2600 (1180)

WS35

G48M28T22EE

300

2 at +2.5%

4 at –2.5%

DT-3

150

919E

292A

2968 (1347)

WS35

G48M28T33EE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

300 (136)

WS38

G48M28F15EE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

403 (183)

WS38

G48M28F30EE

45

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283B

574 (261)

WS39

G48M28F45EE

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

911 (414)

WS19

G48M28F75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

283B

1379 (626)

WS34

G48M28F12EE

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

292A

—

WS34

G48M28F49EE

225

2 at +2.5%

4 at –2.5%

DT-3

115

919E

292A

—

WS35

G48M28F22EE

300

2 at +2.5%

4 at –2.5%

DT-3

115

919E

292A

—

WS35

G48M28F33EE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

340 (154)

WS38

G48M28B15EE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

405 (184)

WS38

G48M28B30EE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283B

580 (263)

WS39

G48M28B45EE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

930 (422)

WS19

G48M28B75EE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

283B

1400 (636)

WS34

G48M28B12EE

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

292A

—

WS34

G48M28B49EE

225

2 at +2.5%

4 at –2.5%

DT-3

80

919E

292A

—

WS35

G48M28B22EE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

292A

—

WS35

G48M28B33EE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Weights subject to change.

2

For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-55

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Single-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2

K-4 240 x 480 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2

2

DS-3

150

816

261A

280 (127)

WS11

HT20P11S15CUEE

25

2

2

DS-3

150

818

261A

431 (195)

WS11

HT20P11S25CUEE

2

37.5

2

2

DS-3

150

818

261A

437 (198)

WS11

HT20P11S37CUEE

2

50

2

2

DS-3

150

819

261A

686 (311)

WS16

HT20P11S50CUEE

75

2

2

DS-3

150

820

261A

—

WS16

HT20P11S75CUEE

2

15

2

2

DS-3

115

816

261A

276 (125)

WS11

HT20P11F15CUEE

25

2

2

DS-3

115

818

261A

435 (197)

WS11

HT20P11F25CUEE

2

37.5

2

2

DS-3

115

818

261A

440 (200)

WS11

HT20P11F37CUEE

2

2

2

50

DS-3

115

820

261A

700 (318)

WS16

HT20P11F50CUEE

75

2

2

DS-3

115

821

261A

—

WS13

HT20P11F75CUEE

2

15

2

2

DS-3

80

816

261A

—

WS11

HT20P11B15CUEE

25

2

2

DS-3

80

818

261A

—

WS11

HT20P11B25CUEE

2

37.5

2

2

DS-3

80

819

261A

—

WS16

HT20P11B37CUEE

50

2

2

DS-3

80

820

261A

—

WS16

HT20P11B50CUEE

75

2

2

DS-3

80

821

261A

—

WS13

HT20P11B75CUEE

2

2
2
2

Full Capacity Taps

K-13 240 x 480 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2

2

DS-3

150

816

261A

283 (128)

WS11

NT20P11S15CUEE

2

25

2

2

DS-3

150

818

261A

420 (191)

WS11

NT20P11S25CUEE

37.5

2

2

DS-3

150

818

261A

425 (193)

WS11

NT20P11S37CUEE

2

50

2

2

DS-3

150

820

261A

690 (313)

WS16

NT20P11S50CUEE

2

2

2

75

DS-3

150

821

261A

1056 (479)

WS13

NT20P11S75CUEE

15

2

2

DS-3

115

818

261A

411 (186)

WS11

NT20P11F15CUEE

2

25

2

2

DS-3

115

818

261A

427 (194)

WS11

NT20P11F25CUEE

37.5

2

2

DS-3

115

819

261A

435 (197)

WS16

NT20P11F37CUEE

2

50

2

2

DS-3

115

820

261A

710 (322)

WS16

NT20P11F50CUEE

75

2

2

DS-3

115

821

261A

1100 (499)

WS13

NT20P11F75CUEE

15

2

2

DS-3

80

818

261A

—

WS11

NT20P11B15CUEE

25

2

2

DS-3

80

818

261A

—

WS11

NT20P11B25CUEE

37.5

2

2

DS-3

80

819

261A

—

WS16

NT20P11B37CUEE

50

2

2

DS-3

80

820

261A

—

WS16

NT20P11B50CUEE

75

2

2

DS-3

80

821

261A

—

WS13

NT20P11B75CUEE

2

2
2
2
2
2

Notes
1 Weights subject to change.
2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
V2-T2-56

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2
2

K-4 480 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

251 (114)

WS38

H48M28T15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

326 (148)

WS38

H48M28T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

479 (217)

WS38

H48M28T45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

463 (210)

WS39

H48M28T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

977 (444)

WS19

H48M28T12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

1212 (550)

WS19

H48M28T49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

917

292A

1815 (824)

WS34

H48M28T22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

150

923

283B

2400 (1090)

WS37

H48M28T33CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

256 (116)

WS38

H48M28F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

341 (155)

WS38

H48M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

526 (239)

WS38

H48M28F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283B

759 (345)

WS39

H48M28F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

1030 (468)

WS19

H48M28F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

115

917

283B

1631 (740)

WS34

H48M28F49CUEE

2
2
2
2
2
2
2
2
2
2

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

292A

1965 (892)

WS34

H48M28F22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

115

923

283B

2337 (1061)

WS37

H48M28F33CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

365 (166)

WS38

H48M28B15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

424 (192)

WS38

H48M28B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283B

653 (296)

WS39

H48M28B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

640 (291)

WS19

H48M28B75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

1264 (574)

WS19

H48M28B12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

80

917

292A

1685 (765)

WS34

H48M28B49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

80

923

292A

2096 (952)

WS37

H48M28B22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3

80

919E

292A

4600 (2087)

WS35

H48M28B33CUEE

2
2
2
2
2

Notes
1 Weights subject to change.

2

For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-57

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2

K-13 480 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

346 (157)

WS38

N48M28T15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

390 (177)

WS38

N48M28T30CUEE

2

45

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

623 (283)

WS39

N48M28T45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

848 (385)

WS19

N48M28T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

1080 (490)

WS19

N48M28T12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

917

292A

1431 (650)

WS34

N48M28T49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

923

292A

2129 (967)

WS37

N48M28T22CUEE

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

341 (155)

WS38

N48M28F15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

444 (202)

WS38

N48M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283B

598 (271)

WS39

N48M28F45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

894 (406)

WS19

N48M28F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

1054 (479)

WS19

N48M28F12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

917

292A

1399 (635)

WS34

N48M28F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

115

923

292A

2088 (948)

WS37

N48M28F22CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

370 (168)

WS38

N48M28B15CUEE

2

2
2
2
2
2
2

Full Capacity Taps

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

490 (222)

WS38

N48M28B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283B

635 (288)

WS39

N48M28B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

987 (448)

WS19

N48M28B75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

854 (388)

WS19

N48M28B12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

283B

1134 (515)

WS34

N48M28B49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

80

919

292A

4091 (1857)

WS35

N48M28B22CUEE

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-58

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.1

Transformers
NEMA TP-1 Energy-Efficient Transformers

Three-Phase—K-Factor Rated 60 Hz NEMA TP-1 Energy-Efficient—Copper Windings

2
2

K-20 480 Delta Volts to 208Y/120 Volts
Full Capacity Taps

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

390 (177)

WS38

G48M28T15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

431 (196)

WS38

G48M28T30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

150

914F

283B

639 (290)

WS39

G48M28T45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

905 (411)

WS19

G48M28T75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

916A

283B

1060 (481)

WS19

G48M28T12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

150

917

283B

1808 (821)

WS34

G48M28T49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

150

923

283B

2386 (1083)

WS37

G48M28T22CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

400 (182)

WS38

G48M28F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

450 (204)

WS38

G48M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

115

914F

283B

690 (313)

WS39

G48M28F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

283B

1148 (521)

WS19

G48M28F75CUEE

2
2
2
2
2
2
2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

283B

—

WS34

G48M28F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

115

923

283B

—

WS37

G48M28F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3

115

919E

292A

—

WS35

G48M28F22CUEE

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

400 (182)

WS38

G48M28B15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

441 (200)

WS38

G48M28B30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3

80

914F

283B

676 (307)

WS39

G48M28B45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

283B

1140 (518)

WS19

G48M28B75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

292A

—

WS34

G48M28B12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3

80

923

292A

2417 (1097)

WS37

G48M28B49CUEE

2

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-59

2.1
2

Transformers
NEMA TP-1 Energy-Efficient Transformers

Accessories
Please refer to Section 2.7 Page V2-T2-191.

2
2

Technical Data and Specifications

2

Frequency
Eaton standard dry-type
distribution transformers are
designed for 60 Hz operation.
Transformers required for
other frequencies are available
and must be specifically
designed.

2
2
2
2
2
2
2
2
2
2
2
2
2

Overload Capability
Short-term overload is
designed into transformers
as required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour, and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250 for
additional limitations.
Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.

2
2

Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:
Insulation System
Classification

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

40°C

80°C

30°C

150°C

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

Average Sound Levels

40°C

150°C

30°C

220°C

NEMA ST-20 Average Sound Level, dB

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.
Enclosures
Eaton ventilated transformers,
Type KT, use a NEMA 2 rated
(drip-proof) enclosure as
standard, and are rated
NEMA 3R with the addition
of weathershields.
Winding Terminations
Primary and secondary
windings are terminated in
the wiring compartment.
Ventilated transformers
have leads brought out to
aluminum pads that are predrilled to accept Cu/Al lugs.
Lugs are not supplied with
these transformers. Eaton
recommends that external
cables be rated 75°C for
ventilated designs.

2
2
2
2
2
2

Sound Levels
All Eaton 600 volt class
general-purpose dry-type
distribution transformers are
designed to meet NEMA
ST-20 sound levels listed
here. These are the sound
levels measured in a
soundproof environment.
Actual sound levels
measured at an installation
will likely be higher due to
electrical connections and

For additional information,
please refer to Section 2.7
Page V2-T2-195.

Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

Encapsulated
(up to 1.2 kV)

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

50.01 to 75.00

50

53

55

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

500.01 to 700.00

62

65

61

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including
stainless steel), refer to Eaton.

2
2
2
2
2
V2-T2-60

environmental conditions.
Lower sound levels are
available and should be
specified when the
transformer is going to be
installed in an area where
sound may be a concern.

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.2

Transformers
NEMA Premium and E3 Super Efficient Transformers

Contents
Description

Page

NEMA Premium Efficient Transformers
Features, Benefits and Functions . . . . . . . . . . .
Standards and Certifications. . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
E3 Super Efficient Transformers . . . . . . . . . . . . . .

V2-T2-62
V2-T2-62
V2-T2-63
V2-T2-63
V2-T2-66

2
2
2
2
2
2
2
2
2
2
2

NEMA Premium® Efficient Transformers
Product Description
Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.

Types DS-3, DT-3
●

●

●
●
●

●

●

Ventilated, NEMA 2
enclosure standard
Suitable for indoor
applications, outdoors
when weathershields
are also installed
Upright mounting only
220ºC insulation system
150ºC rise standard;
115°C or 80°C rise optional
Available in single-phase
ratings 15–167 kVA,
600 volts primary (DS-3)
Available in three-phase
ratings 15–1000 kVA
and up to 600 volts
primary (DT-3)

Application Description
NEMA Premium Efficient
compliant energy-efficient
transformers are specifically
designed to meet the energy
efficiency standards set
forth in NEMA publication
“NEMA Premium Efficiency
Transformer Program
Guidelines.” Surveys have
shown that the average
loading of low voltage
dry-type distribution
transformers, over a 24-hour
period, is approximately 35%.
NEMA Premium compliant
transformers are optimized to
offer maximum efficiency at
35% of nameplate rating.
The range of products
covered by NEMA Premium
Efficient are:
NEMA Premium Efficient
Product Range
Rating

Voltage
Class

Voltage

Single-phase 15–333 kVA

Dry-Type
Rating
Three-phase

15–1000 kVA

Transformers that are
currently specifically excluded
from the scope of NEMA
Premium Program include:
●

●

●

●

●
●

●

●
●

●
●
●

●

●
●

Liquid-filled transformers
below 10 kVA
Dry-type transformers
below 15 kVA
AC and DC drives
transformers
Rectifier transformers
designed for high
harmonics
Autotransformers
Non-distribution
transformers, such as
UPS transformers
Special impedance or
regulation transformers
Regulating transformers
Sealed and non-ventilated
transformers
Machine tool transformers
Welding transformers
Transformers with tap
ranges greater than 15%
Transformers with a
frequency other than 60 Hz
Grounding transformers
Testing transformers

NEMA Premium Efficient
Efficiency Levels
Tables of Energy Efficiency
NEMA Premium Efficiency Levels
Dry-Type Distribution Transformers—
Low Voltage (600V and below)
Single-Phase

Three-Phase

kVA Efficiency

kVA

Efficiency

15

98.39

15

97.90

25

98.60

30

98.25

37.5 98.74

45

98.39

50

98.81

75

98.60

75

98.95

112.5

98.74

100

99.02

150

98.81

167

99.09

225

98.95

250

99.16

300

99.02

333

99.23

500

99.09

—

—

750

99.16

—

—

1000

99.23

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-61

2.2

Transformers
NEMA Premium and E3 Super Efficient Transformers

2

Features, Benefits
and Functions

2

●

2

●

2
2
2
2

●

●

60 Hz operation (except
as noted)
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels
Exceed federal energy
efficiency requirements
for low voltage dry-type
distribution transformers
effective as of
January 1, 2007

2

Standards and Certifications
●

UL listed

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards. All
600 volt class transformers
are UL listed unless
otherwise noted.
Seismically Qualified
Eaton manufactured dry-type
distribution transformers are
seismically qualified and
exceed requirements of the
Uniform Building Code (UBC),
International Building Code
(IBC) and California Code
Title 24.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-62

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.2

Transformers
NEMA Premium and E3 Super Efficient Transformers

Catalog Number Selection

2

Please refer to Section 2.7 Page V2-T2-187.

2
Product Selection
Additional Product Selection information begins on Page V2-T2-189.

2

Three-Phase—Type DT-3 60 Hz NEMA Premium Efficient—Copper Windings

2
2

K-1 480 Volts to 208Y/120 Volts
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T15CUN3

30

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T30CUN3

45

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T45CUN3

75

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T75CUN3

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T12CUN3

150

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T49CUN3

225

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T22CUN3

300

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T33CUN3

15

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F15CUN3

30

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F30CUN3

45

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F45CUN3

75

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F75CUN3

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F12CUN3

150

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F49CUN3

225

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F22CUN3

300

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F33CUN3

15

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B15CUN3

30

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B30CUN3

45

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B45CUN3

75

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B75CUN3

2
2
2
2
2
2
2
2
2
2
2
2
2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B12CUN3

150

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B49CUN3

225

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B22CUN3

2

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-63

2.2
2

Transformers
NEMA Premium and E3 Super Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA Premium Efficient—Copper Windings

2

K-9 480 Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

B48M28T15CUN3

30

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

B48M28T30CUN3

2

45

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

B48M28T45CUN3

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

B48M28T75CUN3

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

B48M28T12CUN3

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

B48M28T49CUN3

225

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

B48M28T22CUN3

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

B48M28T33CUN3

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

B48M28F15CUN3

30

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

B48M28F30CUN3

2

45

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

B48M28F45CUN3

75

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

B48M28F75CUN3

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

B48M28F12CUN3

150

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

B48M28F49CUN3

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

B48M28F22CUN3

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

B48M28F33CUN3

15

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

B48M28B15CUN3

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

B48M28B30CUN3

45

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

B48M28B45CUN3

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

B48M28B75CUN3

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

B48M28B12CUN3

150

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

B48M28B49CUN3

225

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

B48M28B22CUN3

2

2
2
2

Full Capacity Taps

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-64

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.2

Transformers
NEMA Premium and E3 Super Efficient Transformers

Three-Phase—Type DT-3 60 Hz NEMA Premium Efficient—Copper Windings

2
2

K-13 480 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at -2.5%

DT-3

150

—

283C

—

—

N48M28T15CUN3

30

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

N48M28T30CUN3

45

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

N48M28T45CUN3

75

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

N48M28T75CUN3

2
2
2
2

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

N48M28T12CUN3

150

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

N48M28T49CUN3

225

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

N48M28T22CUN3

300

2 at +2.5%

4 at –2.5%

DT-3

150

—

292A

—

—

N48M28T33CUN3

15

2 at +2.5%

4 at –2.5%

DT-3

115

—

283C

—

—

N48M28F15CUN3

30

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

N48M28F30CUN3

45

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

N48M28F45CUN3

75

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

N48M28F75CUN3

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

N48M28F12CUN3

150

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

N48M28F49CUN3

225

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

N48M28F22CUN3

300

2 at +2.5%

4 at –2.5%

DT-3

115

—

292A

—

—

N48M28F33CUN3

15

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

N48M28B15CUN3

30

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

N48M28B30CUN3

45

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

N48M28B45CUN3

75

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

N48M28B75CUN3

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

N48M28B12CUN3

150

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

N48M28B49CUN3

225

2 at +2.5%

4 at –2.5%

DT-3

80

—

292A

—

—

N48M28B22CUN3

2
2
2
2
2
2

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-65

2.2

Transformers
NEMA Premium and E3 Super Efficient Transformers

Contents

2

Description

2

Page

NEMA Premium Efficient Transformers . . . . . . . .
E3 Super Efficient Transformers
Features, Benefits and Functions. . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection. . . . . . . . . . . . . . . . . . . . . . .

2
2
2

V2-T2-61
V2-T2-67
V2-T2-67
V2-T2-68
V2-T2-68

2
2
2
2
2
2

E3 Super Efficient Transformers

2

Product Description

2
2
2
2
2
2
2
2
2
2
2
2
2

Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.

Types DS-3, DT-3
● Ventilated, NEMA 2
enclosure standard
● Suitable for indoor
applications, outdoors
when weathershields
are also installed
● Upright mounting only
● 220ºC insulation system
● 150ºC rise standard;
115°C or 80°C rise optional
● Available in single-phase
ratings 15–167 kVA,
600 volts primary (DS-3)
● Available in three-phase
ratings 15–1000 kVA
and up to 600 volts
primary (DT-3)

Application Description
E3 CSL3-2007energyefficient transformers are
specifically designed to meet
the energy efficiency
guidelines as intended in the
U.S. Department of Energy
10 CFR Parts 430 and 431,
dated October 12, 2007.
Surveys have shown that
the average loading of low
voltage dry-type distribution
transformers, over a 24-hour
period, is approximately 35%.
E3 Efficient transformers are
optimized to offer maximum
efficiency at 35% of
nameplate rating.
Additional clarifications
regarding CSL3-2007 can be
found in NEMA’s whitepaper
“Clarifications on the Use of
Department of Energy
Design—Line 6, 7 and 8
transformers contained
within 10 CFR 430 and 431.”
The range of products
covered by E3 Efficient are:
E3 Efficient Product Range

2

Rating

2

Voltage
Class

Voltage

Dry-Type Single-phase 15–333 kVA
Rating
Three-phase 15–1000 kVA

2

Transformers that are
excluded from the scope
of E3 Efficient transformers
include:
●

●

●

●

●
●

●

●
●

●
●
●

●

●
●

Liquid-filled transformers
below 10 kVA
Dry-type transformers
below 15 kVA
AC and DC drives
transformers
Rectifier transformers
designed for high
harmonics
Autotransformers
Non-distribution
transformers, such as
UPS transformers
Special impedance or
regulation transformers
Regulating transformers
Sealed and non-ventilated
transformers
Machine tool transformers
Welding transformers
Transformers with tap
ranges greater than 15%
Transformers with a
frequency other than 60 Hz
Grounding transformers
Testing transformers

2
2
V2-T2-66

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

E3 Efficient
Efficiency Levels
Tables of Energy Efficiency
E3 Efficiency Levels Dry-Type
Distribution Transformers—
Low Voltage (600V and below)
Single-Phase

Three-Phase

kVA Efficiency

kVA

Efficiency

15

98.23

15

97.97

25

98.44

30

98.29

37.5 98.59

45

98.45

50

98.69

75

98.64

75

98.64

112.5

98.77

100

98.90

150

98.86

167

99.03

225

98.97

250

99.12

300

99.04

333

99.18

500

99.16

—

—

750

99.24

—

—

1000

99.29

Transformers
NEMA Premium and E3 Super Efficient Transformers

Features, Benefits
and Functions
●

●

●

●

60 Hz operation (except
as noted)
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels
Meet or exceed federal
energy efficiency
requirements for
low voltage dry-type
distribution transformers
as intended in U.S. DOE
Document 10 CFR
Parts 430 and 431, dated
October 12, 2007.

2.2

Standards and Certifications
●

2

UL listed

2
2
2

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards. All
600 volt class transformers
are UL listed unless
otherwise noted.

2
2
2
2

Seismically Qualified
Eaton manufactured dry-type
distribution transformers are
seismically qualified and
exceed requirements of the
Uniform Building Code (UBC),
International Building Code
(IBC) and California Code
Title 24.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-67

2.2
2

Transformers
NEMA Premium and E3 Super Efficient Transformers

Catalog Number Selection
Please refer to Section 2.7 Page V2-T2-187.

2
2
2
2
2

Product Selection
Additional Product Selection information begins on Page V2-T2-189.
Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient—Copper Windings

K-1 480 Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T15CUE3

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T30CUE3

2

45

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T45CUE3

75

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T75CUE3

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T12CUE3

150

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T49CUE3

2

225

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T22CUE3

300

2 at +2.5%

4 at –2.5%

DT-3

150

—

283B

—

—

V48M28T33CUE3

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F15CUE3

2

30

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F30CUE3

45

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F45CUE3

2

75

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F75CUE3

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F12CUE3

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F49CUE3

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F22CUE3

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

—

283B

—

—

V48M28F33CUE3

2

15

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B15CUE3

30

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B30CUE3

2

45

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B45CUE3

75

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B75CUE3

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B12CUE3

2

150

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B49CUE3

225

2 at +2.5%

4 at –2.5%

DT-3

80

—

283B

—

—

V48M28B22CUE3

2

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-68

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.2

Transformers
NEMA Premium and E3 Super Efficient Transformers

Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient—Copper Windings

2
2

K-9 480 Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

330 (150)

WS38

B48M28T15CUE3

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

400 (182)

WS38

B48M28T30CUE3

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

283B

630 (286)

WS39

B48M28T45CUE3

75

2 at +2.5%

4 at –2.5%

DT-3

150

915F

283B

865 (393)

WS39

B48M28T75CUE3

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

283B

1520 (690)

WS34

B48M28T12CUE3

150

2 at +2.5%

4 at –2.5%

DT-3

150

917

283B

1650 (749)

WS34

B48M28T49CUE3

225

2 at +2.5%

4 at –2.5%

DT-3

150

918A

283B

2090 (949)

WS34

B48M28T22CUE3

300

2 at +2.5%

4 at –2.5%

DT-3

150

919E

283B

3900 (1771)

WS35

B48M28T33CUE3

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

335 (152)

WS38

B48M28F15CUE3

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

406 (184)

WS38

B48M28F30CUE3

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

283B

635 (288)

WS39

B48M28F45CUE3

75

2 at +2.5%

4 at –2.5%

DT-3

115

915F

283B

870 (395)

WS39

B48M28F75CUE3

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

283B

1526 (693)

WS34

B48M28F12CUE3

150

2 at +2.5%

4 at –2.5%

DT-3

115

917

283B

1665 (756)

WS34

B48M28F49CUE3

2
2
2
2
2
2
2
2
2
2

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

283B

2094 (951)

WS34

B48M28F22CUE3

300

2 at +2.5%

4 at –2.5%

DT-3

115

919E

283B

3900 (1771)

WS35

B48M28F33CUE3

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

406 (184)

WS38

B48M28B15CUE3

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

283B

635 (288)

WS39

B48M28B30CUE3

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

283B

870 (395)

WS39

B48M28B45CUE3

75

2 at +2.5%

4 at –2.5%

DT-3

80

917

283B

1526 (693)

WS34

B48M28B75CUE3

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

283B

1665 (756)

WS34

B48M28B12CUE3

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

283B

2094 (951)

WS34

B48M28B49CUE3

225

2 at +2.5%

4 at –2.5%

DT-3

80

919E

283B

3900 (1771)

WS35

B48M28B22CUE3

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-69

2.2
2

Transformers
NEMA Premium and E3 Super Efficient Transformers

Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient—Copper Windings

2

K-13 480 Delta Volts to 208Y/120 Volts

2

kVA

2

Full Capacity Taps
FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg) 1

Weathershield

Catalog Number

15

2 at +2.5%

4 at -2.5%

DT-3

150

912D

283C

325 (148)

WS38

N48M28T15CUE3

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

283B

370 (168)

WS38

N48M28T30CUE3

2

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

283B

635 (288)

WS39

N48M28T45CUE3

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

915F

283B

870 (395)

WS39

N48M28T75CUE3

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

283B

1526 (693)

WS34

N48M28T12CUE3

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

917

283B

1665 (756)

WS34

N48M28T49CUE3

225

2 at +2.5%

4 at –2.5%

DT-3

150

918A

283B

2094 (951)

WS34

N48M28T22CUE3

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

919E

292A

3900 (1771)

WS35

N48M28T33CUE3

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283C

325 (148)

WS38

N48M28F15CUE3

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

283B

370 (168)

WS38

N48M28F30CUE3

2

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

283B

635 (288)

WS39

N48M28F45CUE3

75

2 at +2.5%

4 at –2.5%

DT-3

115

915F

283B

870 (395)

WS39

N48M28F75CUE3

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

283B

1526 (693)

WS34

N48M28F12CUE3

150

2 at +2.5%

4 at –2.5%

DT-3

115

917

283B

1665 (756)

WS34

N48M28F49CUE3

2

225

2 at +2.5%

4 at –2.5%

DT-3

115

918A

283B

2094 (951)

WS34

N48M28F22CUE3

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

919E

292A

3900 (1771)

WS35

N48M28F33CUE3

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

283B

370 (168)

WS38

N48M28B15CUE3

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

283B

635 (288)

WS39

N48M28B30CUE3

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

283B

870 (395)

WS39

N48M28B45CUE3

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

917

283B

1526 (693)

WS34

N48M28B75CUE3

2
2
2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

283B

1665 (756)

WS34

N48M28B12CUE3

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

283B

2094 (951)

WS34

N48M28B49CUE3

225

2 at +2.5%

4 at –2.5%

DT-3

80

919E

292A

3900 (1771)

WS35

N48M28B22CUE3

Notes
1 Weights subject to change.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-70

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Energy-Efficient Harmonic Mitigating Transformers

2.3

Contents

Harmonic Mitigating Transformer

Description

Page

Energy-Efficient Harmonic Mitigating Transformers
Standards and Certifications. . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
NEMA TP-1 Efficient . . . . . . . . . . . . . . . . . . .
E3 Super Efficient . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications. . . . . . . . . . .

V2-T2-72
V2-T2-72
V2-T2-73
V2-T2-73
V2-T2-81
V2-T2-89
V2-T2-89

2
2
2
2
2
2
2
2
2
2

Product Description
Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.

The electrical transformer
has been a staple of electrical
power systems for the past
100+ years. While the types
of electrical loads that are
being added to our systems
today have radically changed,
the transformer has stayed
relatively the same in
design during this time frame.
Eaton’s harmonic mitigating
transformer (HMT)
represents the evolution
of the transformer into
something that will best
provide clean, energyefficient electricity to
power the loads of today
and tomorrow. The recent
shift of our electrical loads
from predominately AC
consumers (resistive heating
elements, incandescent
lighting, three-phase motor
load) to DC consumers (such
as computers, fax machines,

Features and Benefits
printers, down to the
“wall-wart” that recharges
the cell phone) requires that
our electrical infrastructure
changes as well. These new
loads now introduce other
currents and frequencies
into our electrical power
systems—commonly known
as “harmonics.” Harmonic
currents can cause additional
heating, which may cause
transformers, generators
and conductors to become
overloaded. Excessive heat is
one of the major reasons that
standard transformers and
conductors fail prematurely.
These harmonic currents
have various other effects
(such as “loss of ride-through
capability,” reduced lifespan
and mysterious misoperation
of equipment) on the
components and loads of an
electrical distribution system.
Eaton’s HMTs, when used
properly within an electrical
system, will help keep the
loads operating the way the
manufacturer designed
them and keep the facility’s
electrical system free from
voltage distortion.

Three-Phase, Type DT-3
HMT, 60 Hz
●

●

●

●

●

●

Harmonic mitigating
(cancellation) transformers
are a cost-effective
means of treating harmful
harmonics in an electrical
distribution system
Reducing harmonic
content in electrical
systems can result in a
more reliable electrical
system, lower
maintenance costs,
less downtime, fewer
equipment malfunctions,
and lower cooling
system capacity
Available in a variety of
phase-shift configurations
that allow flexibility to
target specific families
of harmonics
Harmonic treatment via
electromagnetic flux
cancellation
May be installed as a
stand-alone transformer,
or included in IFS™
Available in three-phase
ratings, 15–500 kVA, up to
600 volts primary

●

●

●

●

●
●

●

●
●

●

●

●

●

●

480 volt to 208/120 volt
standard. Additional voltage
combinations available
150°C, 115°C or 80°C
temperature rise available
Copper windings and
terminals standard;
aluminum available
Meet or exceed NEMA
TP-1 energy-efficiency level
200% rated neutral
Single electrostatic shield
for attenuation of common
mode and transverse
mode noise
Approximately 98%
efficient when operated
in systems with 100%
nonlinear load profiles
220°C insulation system
Third-party tested for
harmonic performance
and energy efficiency
Meet NEMA ST-20
sound standards
Eliminate circulating
harmonic currents in
primary windings of
transformers
Enclosures are NEMA 2
drip-proof. The addition of
optional weather-shields
makes the enclosure
NEMA 3R rainproof
Harmonic cancellation
via electromagnetic flux
cancellation. Filters,
capacitors or other such
devices are not used
Help meet IEEE 519
harmonic limits

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-71

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

2.3
2

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Standards and Certifications
●

UL listed

2
2
2
2

Industry Standards

IEEE 519-1992

Seismic Qualified

All Eaton dry-type
transformers are built and
tested in accordance with
applicable NEMA, ANSI and
IEEE standards. Harmonic
mitigating transformers are
UL listed.

Proper use of Eaton’s harmonic
mitigating transformers
within your electrical system
will help you to meet the
harmonic distortion limits as
proposed by IEEE 519-1992,
“IEEE Recommended
Practices and Requirements
for Harmonic Control in
Electrical Power Systems.”

Eaton dry-type distribution
transformers are seismically
qualified and exceed the
requirements of the Uniform
Building Code (UBC),
International Building Code
(IBC) and California Code
Title 24.

2
2
2

Catalog Number Selection

2

Energy-Efficient Harmonic Mitigating Transformers

X 48 M 28 F 30 TCUEE NEG

2
2

Primary Voltage 1
48 = 480 three-phase, three-wire
60 = 600 three-phase, three-wire

2
2

Secondary Voltage 1
28 = 208/120 three-phase, four-wire
47 = 480/277 three-phase, four-wire

Tap Arrangement
M = 2 at +2.5%, 4 at –2.5%
D = 2 at +2.5%, 2 at –2.5%

2

Temperature Rise
F = 115°C (standard)
T = 150°C
B= 80°C

kVA Rating
15 = 15
49 = 150
30 = 30
22 = 225
45 = 45
33 = 300
75 = 75
55 = 500
12 = 112.5

2
2

E3 Efficient
Efficiency Levels

Tables of Energy Efficiency
NEMA Class 1 Efficiency Levels
Dry-Type Distribution Transformers—
Low Voltage (600V and below)

Tables of Energy Efficiency
E3 Efficiency Levels Dry-Type
Distribution Transformers—
Low Voltage (600V and below)

2

Three-Phase

Three-Phase

kVA

Efficiency

kVA

Efficiency

2

15

97.0

15

97.97

30

97.5

30

98.29

2

45

97.7

45

98.45

2

75

98.0

75

98.64

112.5

98.2

112.5

98.77

2

150

98.3

150

98.86

225

98.5

225

98.97

2

300

98.6

300

99.04

500

98.7

500

99.16

750

98.8

750

99.24

1000

98.9

1000

99.29

2

2
2
2

X =
CU =
EE =
SS =
E3 =

NEMA TP-1-2002
Efficiency Levels

2

T =
TT =

Note
1 The most common ratings are shown. Contact Eaton for availability of additional ratings.

2
2
2
V2-T2-72

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Modifications 1
Single thermal sensor (190°C)
Two thermal sensors
(190°C and 175°C)
50/60 Hz
Copper windings (std.)
ENERGY STAR label (std.)
Grade 304 stainless steel
enclosure
Super efficient

Phase Shift
NON = 0º
THR = –30º
POS = +15º
NEG = –15º

2.3

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Product Selection

2

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating

2
2

480 Volts to 208Y/120 Volts—Aluminum Windings—Type NON 0-Degree Phase Shift
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

290 (132)

WS38

X48M28T15EENON

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

365 (166)

WS38

X48M28T30EENON

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

200X

560 (254)

WS39

X48M28T45EENON

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

200X

800 (363)

WS19

X48M28T75EENON

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

200X

1380 (627)

WS34

X48M28T12EENON

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

200X

1560 (708)

WS34

X48M28T49EENON

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

2400 (1090)

WS35

X48M28T22EENON

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

2970 (1348)

WS35

X48M28T33EENON

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

360 (163)

WS38

X48M28F15EENON

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

405 (184)

WS38

X48M28F30EENON

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

200X

575 (261)

WS39

X48M28F45EENON

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

200X

900 (409)

WS19

X48M28F75EENON

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

200X

1380 (627)

WS34

X48M28F12EENON

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

200X

1600 (726)

WS34

X48M28F49EENON

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

2600 (1180)

WS35

X48M28F22EENON

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3100 (1407)

WS35

X48M28F33EENON

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

200X

380 (173)

WS38

X48M28B15EENON

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

560 (254)

WS39

X48M28B30EENON

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

800 (363)

WS39

X48M28B45EENON

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

200X

1380 (627)

WS19

X48M28B75EENON

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

200X

1560 (708)

WS34

X48M28B12EENON

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

200X

2400 (1090)

WS34

X48M28B49EENON

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

2970 (1348)

WS35

X48M28B22EENON

300

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

3400 (1544)

WS35

X48M28B33EENON

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-73

2.3
2

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating

2

480 Volts to 208Y/120 Volts—Copper Windings—Type NON 0-Degree Phase Shift

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

335 (152)

WS38

X48M28T15CUEENON

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

430 (195)

WS38

X48M28T30CUEENON

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

200X

627 (285)

WS39

X48M28T45CUEENON

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

200X

926 (420)

WS19

X48M28T75CUEENON

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

200X

1610 (731)

WS34

X48M28T12CUEENON

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

200X

1800 (817)

WS34

X48M28T49CUEENON

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

3580 (1625)

WS35

X48M28T22CUEENON

Full Capacity Taps

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

3500 (1589)

WS35

X48M28T33CUEENON

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

362 (164)

WS38

X48M28F15CUEENON

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

430 (195)

WS38

X48M28F30CUEENON

2

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

200X

627 (285)

WS39

X48M28F45CUEENON

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

200X

926 (420)

WS19

X48M28F75CUEENON

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

200X

1628 (739)

WS34

X48M28F12CUEENON

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

200X

2001 (908)

WS34

X48M28F49CUEENON

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3596 (1633)

WS35

X48M28F22CUEENON

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3891 (1767)

WS35

X48M28F33CUEENON

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

200X

358 (163)

WS38

X48M28B15CUEENON

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

558 (253)

WS39

X48M28B30CUEENON

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

630 (286)

WS39

X48M28B45CUEENON

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

200X

940 (427)

WS19

X48M28B75CUEENON

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

200X

1628 (739)

WS34

X48M28B12CUEENON

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

200X

1800 (817)

WS34

X48M28B49CUEENON

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

3400 (1544)

WS35

X48M28B22CUEENON

300

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

4377 (1987)

WS35

X48M28B33CUEENON

2
2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-74

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.3

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating

2
2

480 Volts to 208Y/120 Volts—Aluminum Windings—Type THR 30-Degree Phase Shift
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

290 (132)

WS38

X48M28T15EETHR

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

365 (166)

WS38

X48M28T30EETHR

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

200X

560 (254)

WS39

X48M28T45EETHR

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

200X

800 (363)

WS19

X48M28T75EETHR

Catalog Number

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

200X

1380 (627)

WS34

X48M28T12EETHR

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

200X

1560 (708)

WS34

X48M28T49EETHR

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

2400 (1090)

WS35

X48M28T22EETHR

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

2970 (1348)

WS35

X48M28T33EETHR

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

360 (163)

WS38

X48M28F15EETHR

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

405 (184)

WS38

X48M28F30EETHR

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

200X

575 (261)

WS39

X48M28F45EETHR

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

200X

900 (409)

WS19

X48M28F75EETHR

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

200X

1380 (627)

WS34

X48M28F12EETHR

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

200X

1600 (726)

WS34

X48M28F49EETHR

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

2600 (1180)

WS35

X48M28F22EETHR

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3100 (1407)

WS35

X48M28F33EETHR

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

200X

380 (173)

WS38

X48M28B15EETHR

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

560 (254)

WS39

X48M28B30EETHR

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

800 (363)

WS39

X48M28B45EETHR

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

200X

1380 (627)

WS19

X48M28B75EETHR

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

200X

1560 (708)

WS34

X48M28B12EETHR

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

200X

2400 (1090)

WS34

X48M28B49EETHR

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

2970 (1348)

WS35

X48M28B22EETHR

300

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

3400 (1544)

WS35

X48M28B33EETHR

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-75

2.3
2

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating

2

480 Volts to 208Y/120 Volts—Copper Windings—Type THR 30-Degree Phase Shift

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

203X

335 (152)

WS38

X48M28T15CUEETHR

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

203X

450 (204)

WS38

X48M28T30CUEETHR

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

203X

627 (285)

WS39

X48M28T45CUEETHR

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

203X

855 (388)

WS19

X48M28T75CUEETHR

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

203X

1610 (731)

WS34

X48M28T12CUEETHR

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

203X

1800 (817)

WS34

X48M28T49CUEETHR

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

203X

3450 (1566)

WS35

X48M28T22CUEETHR

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

203X

3894 (1768)

WS35

X48M28T33CUEETHR

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

203X

362 (164)

WS38

X48M28F15CUEETHR

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

203X

450 (204)

WS38

X48M28F30CUEETHR

2

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

203X

610 (277)

WS39

X48M28F45CUEETHR

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

203X

868 (394)

WS19

X48M28F75CUEETHR

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

203X

1643 (746)

WS34

X48M28F12CUEETHR

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

203X

2001 (908)

WS34

X48M28F49CUEETHR

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

203X

3370 (1530)

WS35

X48M28F22CUEETHR

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

203X

3894 (1768)

WS35

X48M28F33CUEETHR

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

203X

358 (163)

WS38

X48M28B15CUEETHR

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

203X

558 (253)

WS39

X48M28B30CUEETHR

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

203X

630 (286)

WS39

X48M28B45CUEETHR

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

203X

940 (427)

WS19

X48M28B75CUEETHR

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

203X

1628 (739)

WS34

X48M28B12CUEETHR

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

203X

1800 (817)

WS34

X48M28B49CUEETHR

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

203X

3400 (1544)

WS35

X48M28B22CUEETHR

300

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

203X

4417 (2005)

WS35

X48M28B33CUEETHR

2
2

Full Capacity Taps

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-76

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.3

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating

2
2

480 Volts to 208Y/120 Volts—Aluminum Windings—Type NEG –15-Degree Phase Shift
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

2

Weight
Lbs (kg)

Weathershield

200X

290 (132)

WS38

X48M28T15EENEG

200X

365 (166)

WS38

X48M28T30EENEG

Catalog Number

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

200X

560 (254)

WS39

X48M28T45EENEG

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

200X

800 (363)

WS19

X48M28T75EENEG

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

200X

1380 (627)

WS34

X48M28T12EENEG

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

200X

1560 (708)

WS34

X48M28T49EENEG

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

2400 (1090)

WS35

X48M28T22EENEG

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

2970 (1348)

WS35

X48M28T33EENEG

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

360 (163)

WS38

X48M28F15EENEG

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

405 (184)

WS38

X48M28F30EENEG

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

200X

575 (261)

WS39

X48M28F45EENEG

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

200X

900 (409)

WS19

X48M28F75EENEG

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

200X

1380 (627)

WS34

X48M28F12EENEG

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

200X

1600 (726)

WS34

X48M28F49EENEG

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

2600 (1180)

WS35

X48M28F22EENEG

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3100 (1407)

WS35

X48M28F33EENEG

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

200X

380 (173)

WS38

X48M28B15EENEG

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

560 (254)

WS39

X48M28B30EENEG

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

800 (363)

WS39

X48M28B45EENEG

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

200X

1380 (627)

WS19

X48M28B75EENEG

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

200X

1560 (708)

WS34

X48M28B12EENEG

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

200X

2400 (1090)

WS34

X48M28B49EENEG

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

2970 (1348)

WS35

X48M28B22EENEG

300

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

3400 (1544)

WS35

X48M28B33EENEG

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-77

2.3
2

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating

2

480 Volts to 208Y/120 Volts—Copper Windings—Type NEG –15-Degree Phase Shift

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

335 (152)

WS38

X48M28T15CUEENEG

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

430 (195)

WS38

X48M28T30CUEENEG

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

200X

627 (285)

WS39

X48M28T45CUEENEG

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

200X

926 (420)

WS19

X48M28T75CUEENEG

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

200X

1610 (731)

WS34

X48M28T12CUEENEG

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

200X

1800 (817)

WS34

X48M28T49CUEENEG

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

200X

3580 (1625)

WS35

X48M28T22CUEENEG

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

200X

3500 (1589)

WS35

X48M28T33CUEENEG

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

353 (160)

WS38

X48M28F15CUEENEG

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

430 (195)

WS38

X48M28F30CUEENEG

2

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

200X

627 (285)

WS39

X48M28F45CUEENEG

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

200X

926 (420)

WS19

X48M28F75CUEENEG

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

200X

1628 (739)

WS34

X48M28F12CUEENEG

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

200X

2001 (908)

WS34

X48M28F49CUEENEG

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

200X

3596 (1633)

WS35

X48M28F22CUEENEG

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

200X

3891 (1767)

WS35

X48M28F33CUEENEG

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

200X

358 (163)

WS38

X48M28B15CUEENEG

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

558 (253)

WS39

X48M28B30CUEENEG

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

630 (286)

WS39

X48M28B45CUEENEG

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

200X

940 (427)

WS19

X48M28B75CUEENEG

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

200X

1628 (739)

WS34

X48M28B12CUEENEG

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

200X

1800 (817)

WS34

X48M28B49CUEENEG

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

200X

3400 (1544)

WS35

X48M28B22CUEENEG

300

2 at +2.5%

4 at –2.5%

DT-3

80

920EX

200X

4377 (1987)

WS35

X48M28B33CUEENEG

2
2

2
2

Full Capacity Taps

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-78

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.3

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating

2
2

480 Volts to 208Y/120 Volts—Aluminum Windings—Type POS +15-Degree Phase Shift
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

45

2 at +2.5%

4 at –2.5%

DT-3

150

75

2 at +2.5%

4 at –2.5%

DT-3

150

2

Weight
Lbs (kg)

Weathershield

Catalog Number

200X

290 (132)

WS38

X48M28T15EEPOS

200X

365 (166)

WS38

X48M28T30EEPOS

915F

200X

560 (254)

WS39

X48M28T45EEPOS

916A

200X

800 (363)

WS19

X48M28T75EEPOS

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

200X

1380 (627)

WS34

X48M28T12EEPOS

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

200X

1560 (708)

WS34

X48M28T49EEPOS

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

2400 (1090)

WS35

X48M28T22EEPOS

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

2970 (1348)

WS35

X48M28T33EEPOS

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

360 (163)

WS38

X48M28F15EEPOS

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

405 (184)

WS38

X48M28F30EEPOS

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

200X

575 (261)

WS39

X48M28F45EEPOS

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

200X

900 (409)

WS19

X48M28F75EEPOS

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

200X

1380 (627)

WS34

X48M28F12EEPOS

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

200X

1600 (726)

WS34

X48M28F49EEPOS

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

2600 (1180)

WS35

X48M28F22EEPOS

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3100 (1407)

WS35

X48M28F33EEPOS

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

200X

380 (173)

WS38

X48M28B15EEPOS

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

560 (254)

WS39

X48M28B30EEPOS

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

800 (363)

WS39

X48M28B45EEPOS

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

200X

1380 (627)

WS19

X48M28B75EEPOS

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

200X

1560 (708)

WS34

X48M28B12EEPOS

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

200X

2400 (1090)

WS34

X48M28B49EEPOS

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

2970 (1348)

WS35

X48M28B22EEPOS

300

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

3400 (1544)

WS35

X48M28B33EEPOS

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-79

2.3
2

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Harmonic Mitigating

2

480 Volts to 208Y/120 Volts—Copper Windings—Type POS +15-Degree Phase Shift

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

335 (152)

WS38

X48M28T15CUEEPOS

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

430 (195)

WS38

X48M28T30CUEEPOS

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

200X

627 (285)

WS39

X48M28T45CUEEPOS

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

200X

926 (420)

WS19

X48M28T75CUEEPOS

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

200X

1610 (731)

WS34

X48M28T12CUEEPOS

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

200X

1800 (817)

WS34

X48M28T49CUEEPOS

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

3580 (1625)

WS35

X48M28T22CUEEPOS

Full Capacity Taps

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

3500 (1589)

WS35

X48M28T33CUEEPOS

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

362 (164)

WS38

X48M28F15CUEEPOS

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

430 (195)

WS38

X48M28F30CUEEPOS

2

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

200X

627 (285)

WS39

X48M28F45CUEEPOS

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

200X

926 (420)

WS19

X48M28F75CUEEPOS

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

200X

1628 (739)

WS34

X48M28F12CUEEPOS

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

200X

2001 (908)

WS34

X48M28F49CUEEPOS

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3596 (1633)

WS35

X48M28F22CUEEPOS

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3891 (1767)

WS35

X48M28F33CUEEPOS

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

200X

358 (163)

WS38

X48M28B15CUEEPOS

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

558 (253)

WS39

X48M28B30CUEEPOS

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

630 (286)

WS39

X48M28B45CUEEPOS

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

200X

940 (427)

WS19

X48M28B75CUEEPOS

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

200X

1628 (739)

WS34

X48M28B12CUEEPOS

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

200X

1800 (817)

WS34

X48M28B49CUEEPOS

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

3400 (1544)

WS35

X48M28B22CUEEPOS

300

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

4377 (1987)

WS35

X48M28B33CUEEPOS

2
2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-80

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.3

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating

2
2

480 Volts to 208Y/120 Volts—Aluminum Windings—Type NON 0-Degree Phase Shift
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T15E3NON

30

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T30E3NON

45

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T45E3NON

75

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T75E3NON

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T12E3NON

150

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T49E3NON

225

2 at +2.5%

4 at –2.5%

DT-3

150

—

201X

—

—

X48M28T22E3NON

300

2 at +2.5%

4 at –2.5%

DT-3

150

—

201X

—

—

X48M28T33E3NON

15

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F15E3NON

30

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F30E3NON

45

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F45E3NON

75

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F75E3NON

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F12E3NON

150

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F49E3NON

225

2 at +2.5%

4 at –2.5%

DT-3

115

—

201X

—

—

X48M28F22E3NON

300

2 at +2.5%

4 at –2.5%

DT-3

115

—

201X

—

—

X48M28F33E3NON

15

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B15E3NON

30

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B30E3NON

45

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B45E3NON

75

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B75E3NON

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B12E3NON

150

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B49E3NON

225

2 at +2.5%

4 at –2.5%

DT-3

80

—

201X

—

—

X48M28B22E3NON

300

2 at +2.5%

4 at –2.5%

DT-3

80

—

201X

—

—

X48M28B33E3NON

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-81

2.3
2

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating

2

480 Volts to 208Y/120 Volts—Copper Windings—Type NON 0-Degree Phase Shift

2

kVA

FCAN

FCBN

Type

ºC Temp
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

335 (152)

WS38

X48M28T15CUE3NON

2
2
2
2
2

Full Capacity Taps

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

430 (195)

WS38

X48M28T30CUE3NON

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

200X

627 (285)

WS39

X48M28T45CUE3NON
X48M28T75CUE3NON

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

200X

926 (420)

WS19

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

200X

1610 (731)

WS34

X48M28T12CUE3NON

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

200X

1800 (817)

WS34

X48M28T49CUE3NON

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

3580 (1625)

WS35

X48M28T22CUE3NON

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

3500 (1589)

WS35

X48M28T33CUE3NON

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

362 (164)

WS38

X48M28F15CUE3NON

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

430 (195)

WS38

X48M28F30CUE3NON

2

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

200X

627 (285)

WS39

X48M28F45CUE3NON

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

200X

926 (420)

WS19

X48M28F75CUE3NON

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

200X

1628 (739)

WS34

X48M28F12CUE3NON

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

200X

2001 (908)

WS34

X48M28F49CUE3NON

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3596 (1633)

WS35

X48M28F22CUE3NON

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3891 (1767)

WS35

X48M28F33CUE3NON

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

200X

358 (163)

WS38

X48M28B15CUE3NON

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

558 (253)

WS39

X48M28B30CUE3NON

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

630 (286)

WS39

X48M28B45CUE3NON

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

200X

940 (427)

WS19

X48M28B75CUE3NON

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

200X

1628 (739)

WS34

X48M28B12CUE3NON

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

200X

1800 (817)

WS34

X48M28B49CUE3NON

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

3400 (1544)

WS35

X48M28B22CUE3NON

300

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

4377 (1987)

WS35

X48M28B33CUE3NON

2

2
2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-82

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.3

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating

2
2

480 Volts to 208Y/120 Volts—Aluminum Windings—Type THR 30-Degree Phase Shift
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T15E3THR

30

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T30E3THR

45

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T45E3THR

75

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T75E3THR

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T12E3THR

150

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T49E3THR

225

2 at +2.5%

4 at –2.5%

DT-3

150

—

201X

—

—

X48M28T22E3THR

300

2 at +2.5%

4 at –2.5%

DT-3

150

—

201X

—

—

X48M28T33E3THR

15

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F15E3THR

30

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F30E3THR

45

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F45E3THR

75

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F75E3THR

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F12E3THR

150

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F49E3THR

225

2 at +2.5%

4 at –2.5%

DT-3

115

—

201X

—

—

X48M28F22E3THR

300

2 at +2.5%

4 at –2.5%

DT-3

115

—

201X

—

—

X48M28F33E3THR

15

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B15E3THR

30

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B30E3THR

45

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B45E3THR

75

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B75E3THR

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B12E3THR

150

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B49E3THR

225

2 at +2.5%

4 at –2.5%

DT-3

80

—

201X

—

—

X48M28B22E3THR

300

2 at +2.5%

4 at –2.5%

DT-3

80

—

201X

—

—

X48M28B33E3THR

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-83

2.3
2

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating

2

480 Volts to 208Y/120 Volts—Copper Windings—Type THR 30-Degree Phase Shift

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

203X

335 (152)

WS38

X48M28T15CUE3THR

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

203X

450 (204)

WS38

X48M28T30CUE3THR

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

203X

627 (285)

WS39

X48M28T45CUE3THR

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

203X

855 (388)

WS19

X48M28T75CUE3THR

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

203X

1610 (731)

WS34

X48M28T12CUE3THR

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

203X

1800 (817)

WS34

X48M28T49CUE3THR

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

203X

3450 (1566)

WS35

X48M28T22CUE3THR

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

203X

3894 (1768)

WS35

X48M28T33CUE3THR

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

203X

362 (164)

WS38

X48M28F15CUE3THR

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

203X

450 (204)

WS38

X48M28F30CUE3THR

2

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

203X

610 (277)

WS39

X48M28F45CUE3THR

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

203X

868 (394)

WS19

X48M28F75CUE3THR

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

203X

1643 (746)

WS34

X48M28F12CUE3THR

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

203X

2001 (908)

WS34

X48M28F49CUE3THR

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

203X

3370 (1530)

WS35

X48M28F22CUE3THR

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

203X

3894 (1768)

WS35

X48M28F33CUE3THR

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

203X

358 (163)

WS38

X48M28B15CUE3THR

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

203X

558 (253)

WS39

X48M28B30CUE3THR

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

203X

630 (286)

WS39

X48M28B45CUE3THR

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

203X

940 (427)

WS19

X48M28B75CUE3THR

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

203X

1628 (739)

WS34

X48M28B12CUE3THR

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

203X

1800 (817)

WS34

X48M28B49CUE3THR

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

203X

3400 (1544)

WS35

X48M28B22CUE3THR

2
2

Full Capacity Taps

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-84

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.3

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating

2
2

480 Volts to 208Y/120 Volts—Aluminum Windings—Type NEG –15-Degree Phase Shift
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at -2.5%

DT-3

150

—

200X

—

—

X48M28T15E3NEG

30

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T30E3NEG

45

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T45E3NEG

75

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T75E3NEG

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T12E3NEG

150

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T49E3NEG

225

2 at +2.5%

4 at –2.5%

DT-3

150

—

201X

—

—

X48M28T22E3NEG

300

2 at +2.5%

4 at –2.5%

DT-3

150

—

201X

—

—

X48M28T33E3NEG

15

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F15E3NEG

30

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F30E3NEG

45

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F45E3NEG

75

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F75E3NEG

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F12E3NEG

150

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F49E3NEG

225

2 at +2.5%

4 at –2.5%

DT-3

115

—

201X

—

—

X48M28F22E3NEG

300

2 at +2.5%

4 at –2.5%

DT-3

115

—

201X

—

—

X48M28F33E3NEG

15

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B15E3NEG

30

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B30E3NEG

45

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B45E3NEG

75

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B75E3NEG

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B12E3NEG

150

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B49E3NEG

225

2 at +2.5%

4 at –2.5%

DT-3

80

—

201X

—

—

X48M28B22E3NEG

300

2 at +2.5%

4 at –2.5%

DT-3

80

—

201X

—

—

X48M28B33E3NEG

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-85

2.3
2

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating

2

480 Volts to 208Y/120 Volts—Copper Windings—Type NEG –15-Degree Phase Shift

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

335 (152)

WS38

X48M28T15CUE3NEG

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

430 (195)

WS38

X48M28T30CUE3NEG

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

200X

627 (285)

WS39

X48M28T45CUE3NEG

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

200X

926 (420)

WS19

X48M28T75CUE3NEG

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

200X

1610 (731)

WS34

X48M28T12CUE3NEG

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

200X

1800 (817)

WS34

X48M28T49CUE3NEG

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

200X

3580 (1625)

WS35

X48M28T22CUE3NEG

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

200X

3500 (1589)

WS35

X48M28T33CUE3NEG

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

353 (160)

WS38

X48M28F15CUE3NEG

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

430 (195)

WS38

X48M28F30CUE3NEG

2

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

200X

627 (285)

WS39

X48M28F45CUE3NEG

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

200X

926 (420)

WS19

X48M28F75CUE3NEG

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

200X

1628 (739)

WS34

X48M28F12CUE3NEG

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

200X

2001 (908)

WS34

X48M28F49CUE3NEG

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

200X

3596 (1633)

WS35

X48M28F22CUE3NEG

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

200X

3891 (1767)

WS35

X48M28F33CUE3NEG

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

200X

358 (163)

WS38

X48M28B15CUE3NEG

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

558 (253)

WS39

X48M28B30CUE3NEG

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

630 (286)

WS39

X48M28B45CUE3NEG

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

200X

940 (427)

WS19

X48M28B75CUE3NEG

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

200X

1628 (739)

WS34

X48M28B12CUE3NEG

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

200X

1800 (817)

WS34

X48M28B49CUE3NEG

2

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

200X

3400 (1544)

WS35

X48M28B22CUE3NEG

300

2 at +2.5%

4 at –2.5%

DT-3

80

920EX

200X

4377 (1987)

WS35

X48M28B33CUE3NEG

2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

Full Capacity Taps

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-86

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.3

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating

2
2

480 Volts to 208Y/120 Volts—Aluminum Windings—Type POS +15-Degree Phase Shift
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T15E3POS

30

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T30E3POS

45

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T45E3POS

75

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T75E3POS

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T12E3POS

150

2 at +2.5%

4 at –2.5%

DT-3

150

—

200X

—

—

X48M28T49E3POS

225

2 at +2.5%

4 at –2.5%

DT-3

150

—

201X

—

—

X48M28T22E3POS

300

2 at +2.5%

4 at –2.5%

DT-3

150

—

201X

—

—

X48M28T33E3POS

15

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F15E3POS

30

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F30E3POS

45

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F45E3POS

75

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F75E3POS

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F12E3POS

150

2 at +2.5%

4 at –2.5%

DT-3

115

—

200X

—

—

X48M28F49E3POS

225

2 at +2.5%

4 at –2.5%

DT-3

115

—

201X

—

—

X48M28F22E3POS

300

2 at +2.5%

4 at –2.5%

DT-3

115

—

201X

—

—

X48M28F33E3POS

15

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B15E3POS

30

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B30E3POS

45

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B45E3POS

75

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B75E3POS

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B12E3POS

150

2 at +2.5%

4 at –2.5%

DT-3

80

—

200X

—

—

X48M28B49E3POS

225

2 at +2.5%

4 at –2.5%

DT-3

80

—

201X

—

—

X48M28B22E3POS

300

2 at +2.5%

4 at –2.5%

DT-3

80

—

201X

—

—

X48M28B33E3POS

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-87

2.3
2

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Three-Phase—Type DT-3 60 Hz E3 Super Energy-Efficient Harmonic Mitigating

2

480 Volts to 208Y/120 Volts—Copper Windings—Type POS +15-Degree Phase Shift

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

335 (152)

WS38

X48M28T15CUE3POS

2

30

2 at +2.5%

4 at –2.5%

DT-3

150

912D

200X

430 (195)

WS38

X48M28T30CUE3POS

45

2 at +2.5%

4 at –2.5%

DT-3

150

915F

200X

627 (285)

WS39

X48M28T45CUE3POS

2

75

2 at +2.5%

4 at –2.5%

DT-3

150

916A

200X

926 (420)

WS19

X48M28T75CUE3POS

112.5

2 at +2.5%

4 at –2.5%

DT-3

150

917

200X

1610 (731)

WS34

X48M28T12CUE3POS

2

150

2 at +2.5%

4 at –2.5%

DT-3

150

918A

200X

1800 (817)

WS34

X48M28T49CUE3POS

225

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

3580 (1625)

WS35

X48M28T22CUE3POS

2

300

2 at +2.5%

4 at –2.5%

DT-3

150

919EX

201X

3500 (1589)

WS35

X48M28T33CUE3POS

2

15

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

362 (164)

WS38

X48M28F15CUE3POS

30

2 at +2.5%

4 at –2.5%

DT-3

115

912D

200X

430 (195)

WS38

X48M28F30CUE3POS

2

45

2 at +2.5%

4 at –2.5%

DT-3

115

915F

200X

627 (285)

WS39

X48M28F45CUE3POS

75

2 at +2.5%

4 at –2.5%

DT-3

115

916A

200X

926 (420)

WS19

X48M28F75CUE3POS

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

115

917

200X

1628 (739)

WS34

X48M28F12CUE3POS

2

150

2 at +2.5%

4 at –2.5%

DT-3

115

918A

200X

2001 (908)

WS34

X48M28F49CUE3POS

225

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3596 (1633)

WS35

X48M28F22CUE3POS

2

300

2 at +2.5%

4 at –2.5%

DT-3

115

919EX

201X

3891 (1767)

WS35

X48M28F33CUE3POS

15

2 at +2.5%

4 at –2.5%

DT-3

80

912D

200X

358 (163)

WS38

X48M28B15CUE3POS

2

30

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

558 (253)

WS39

X48M28B30CUE3POS

45

2 at +2.5%

4 at –2.5%

DT-3

80

915F

200X

630 (286)

WS39

X48M28B45CUE3POS

2

75

2 at +2.5%

4 at –2.5%

DT-3

80

916A

200X

940 (427)

WS19

X48M28B75CUE3POS

2

112.5

2 at +2.5%

4 at –2.5%

DT-3

80

917

200X

1628 (739)

WS34

X48M28B12CUE3POS

150

2 at +2.5%

4 at –2.5%

DT-3

80

918A

200X

1800 (817)

WS34

X48M28B49CUE3POS

225

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

3400 (1544)

WS35

X48M28B22CUE3POS

300

2 at +2.5%

4 at –2.5%

DT-3

80

919EX

201X

4377 (1987)

WS35

X48M28B33CUE3POS

2
2

Full Capacity Taps

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-88

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.3

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Accessories

2

Harmonic mitigating
transformers are available
with the same options and
accessories as generalpurpose ventilated
transformers. Please
refer to Section 2.7
Page V2-T2-191.

2
2
2
2

Technical Data and Specifications
Frequency
Eaton standard dry-type
distribution transformers are
designed for 60 Hz operation.
Transformers required for
other frequencies are
available and must be
specifically designed.

Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:

All Eaton 600 volt class
general-purpose dry-type
distribution transformers
are designed to meet

Insulation System
Classification

Average Sound Levels

Overload Capacity
Short-term overload is
designed into transformers as
required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour; 150% load
for one hour and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250
for additional limitations.
Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.

2

Sound Levels

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

40°C

80°C

30°C

150°C

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

40°C

150°C

30°C

220°C

NEMA ST-20 levels listed
here. Lower sound levels
are available and must be
designed specially.

2
2
2
2

NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
K-Factor 1, 4, 9
K-Factor 13, 20
kVA Range

Encapsulated
(up to 1.2 kV)

2
2

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.

50.01 to 75.00

50

53

55

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

Enclosures

500.01 to 700.00

62

65

61

Eaton ventilated transformers
Types DS-3 and DT-3 use a
NEMA 2 rated (drip-proof)
enclosure as a standard, and
are rated NEMA 3R with the
addition of weathershields.

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

2
2
2
2
2
2

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including
stainless steel), refer to Eaton.

2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-89

2.3

Transformers
Energy-Efficient Harmonic Mitigating Transformers

2

Demystifying Harmonic Mitigating Transformer Myths

2

Aren’t “power factor corrected”
computer power supplies fixing
all harmonics?
The use of power factor
corrected computer power
supplies is a great first start
to reducing harmonic currents
in your facility. These are
becoming prevalent in server
applications, but have not
“crossed-over” into the laptop
computer/business computer.
Remember also that, once the
computer power supply
harmonics are addressed,
you will still need to address
the harmonic currents coming
from the variety of other
equipment in your facility.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Don’t K-rated transformers
fix harmonics?
The K-rated transformer
was created to address
the additional heat being
produced by standard deltawye transformers when
feeding nonlinear loads.
The goal of the K-rated
transformer is to dissipate the
heat produced over a larger
area, thus providing
the illusion of correction.
The K-rated transformer
does nothing to reduce
the root issue of harmonic
currents or correct power
quality issues. Because of
their larger size, they also
consume additional energy
to “do the same work” and
are counter-productive to an
energy-efficient electrical
distribution design.
Don’t you need two HMTs for
any correction to occur?
The design of HMTs allows
them to address different
families of harmonic currents
in different ways. A single
HMT will treat the triplen
(3rd, 9th, 15th and so on)
harmonic currents in its
secondary winding. The 5th,
7th, 17th and 19th harmonic
family is treated on a system
basis through a technique
known as “phase shifting.”

This phase shift does occur
between the Type NON and
Type THR, and the Type POS
and Type NEG harmonic
mitigating transformers—and
this can also occur between
a Type NON and a standard
delta-wye transformer (that
is probably already existing
within your facility). See our
Sample HMT Applications
area for additional information.
The cost of HMTs is too high!
While the initial cost of HMTs
is typically 1.5 to 4 times the
cost of a standard transformer
(due to the additional design,
materials and labor involved
in creating the magnetics
necessary to reduce harmonic
impact)—to not use an HMT in
a harmonic environment will
actually cost you 250% more
energy loss in the transformer.
Due to the relatively long life of
a transformer (20–30 years),
these additional energy costs
easily overshadow the initial
one-time first cost increment.
If I use one HMT, don’t I need to
change all my transformers?
Most facilities have only a
percentage (typically 20–25%)
of their electrical system that
really requires the use of an
HMT. This means in a typical
building that only a few areas
are either critical (meaning
high requirements for
“clean” power) or have high
concentrations of electronic,
nonlinear loads—requiring
the use of the HMT in those
specific areas. The harmonic
mitigating transformer is a
weapon in your arsenal in
providing a complete, properly
designed electrical system for
today and tomorrow.

Transformer Technology Table Explanation
In understanding the product
placement of the HMT, it
becomes useful to have
some “rule of thumb”
understanding to compare
products. Looking at one of
the aspects of an HMT—
price—you can see that,
if a standard delta-wye
transformer had a cost of
one unit, a K-13 transformer
would cost about double and
an HMT would cost 1.5 to
4 times the unit cost. What’s
impressive to compare is the
next column of information—
”Energy Savings.” If the
amount of energy used to
power today’s loads is
compared against a standard
delta-wye transformer (that
was never designed to feed
today’s types of loads), you
can easily see that the HMT
is designed to meet the issue
head-on! Referring to the
table’s information, you can
see that it would take 30%
more energy to power the
same computer loads with
a K-13 transformer, whereas
an HMT would take 25% less
energy to feed those same

Transformer Technology Comparison 1
Transformer Type

Cost

Energy Savings

Power Quality

Standard delta-wye

if 1X

if 1X

Not designed for harmonics

K-13

1.5–2X

–0.3X

Bulked up—doesn’t help

HMT

2.5X

2.5X

Corrects root issue

Note
1 Comparing cost, energy savings and power quality performance between the “commonly
used” transformer types.

2
2
2
V2-T2-90

computer loads. (This is due
to the fact that the HMT
has a different design
than a standard delta-wye
transformer and addresses
the root issue of harmonic
currents.) A good analogy is
to look at the incandescent
light bulb versus a compact
fluorescent lamp—you might
pay a bit more up front, but
because of the large energy
savings (because of the
harmonic loading), you soon
realize that the upfront cost
pales in comparison to the
potential of energy saved.
Eaton would be happy
to provide you with an
estimation calculator to
help you determine the
amount of payback and return
on investment (ROI) based
on the incremental cost of
the HMT. It’s very typical to
return the price differential
between the HMT and a
standard transformer with a
few years—thus using the
additional 20 to 30 years of
energy savings to add to your
bottom line.

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Energy-Efficient Harmonic Mitigating Transformers

2.3

Sample HMT Applications
Typical Application of Type NON Transformer
Type NON

2

Typical Application of Type NON Transformer
with a Standard Delta-Wye Transformer

Electrical Panel
Feeding Single-Phase
and/or Three-Phase
Nonlinear Loads

2

Type NON

-Y Transformer

2

Electrical Panel
Feeding Single-Phase
and/or Three-Phase
Nonlinear Loads

2
2

Type NON
Long Run

2

Electrical Bus

Installation of a Type NON
transformer provides an
effective treatment of triplen
(3rd, 9th, 15th and so on)
harmonic currents that
are generated by loads
connected to the transformer.
Triplen harmonic currents
are treated in the secondary
windings of the transformer
due to the transformer’s low
zero sequence impedance.
Type NON transformers
do not need to be used in
combination with other
transformers to treat triplen
harmonic currents. A single
Type NON transformer may
be installed, or multiple units
can be applied.

2

Type NON

Long Run

Type NON transformers are
an ideal solution for treating
triplen harmonics generated
by personal computers,
printers, fax machines and
other office equipment,
as well as by single-phase
electronic ballasts, and singlephase electronic testing or
monitoring devices.

Electrical Bus

When a delta-wye transformer
exists in an electrical
distribution system, the
addition of a Type NON
transformer offers an
economical solution for treating
harmonic currents. The 30°
phase-shift created between a
Type NON harmonic mitigating
transformer and a delta-wye
transformer (standard
transformer or K-Factor
transformer) provides
treatment of 5th, 7th, 17th
and 19th harmonic currents.
These harmonic currents are
canceled in the common
electrical bus that feeds the
transformers. Additionally,

2
2

-Y Transformer

2

triplen (3rd, 9th, 15th and
so on) harmonic currents
generated by the loads
connected to the Type NON
transformer will be treated
in the secondary windings of
the Type NON transformer
due to its low zero sequence
impedance. When using two
or more transformers to treat
harmonics, it is better that the
load be split equally between
the transformers to receive the
maximum benefit.
Note: Triplen currents will still
circulate in the delta-wye
transformer for additional waste.
See figure on Page V2-T2-92 to
correct.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-91

2.3
2

Transformers
Energy-Efficient Harmonic Mitigating Transformers

Optimum Application of Type NON and
Type THR Transformers

2

Type NON

2
Type THR

2
2

Typical Application of Type NEG and
Type POS Transformers
Type NEG

Electrical Panel
Feeding Single-Phase
and/or Three-Phase
Nonlinear Loads

Type POS

Type NON

2
2

Long Run

Electrical Panel
Feeding Single-Phase
and/or Three-Phase
Nonlinear Loads

Type NEG

Long Run

2
2
2
2
2
2
2
2
2
2

Type THR

Electrical Bus

When you’re searching for an
optimum harmonic correction
solution in an electrical
distribution system, the
combination of a Type NON
and Type THR transformer
offers a great solution.
The 30° phase shift created
between Type NON and type
THR harmonic mitigating
transformers provides
treatment of 5th, 7th, 17th
and 19th harmonic currents.
These harmonic currents are
canceled in the common
electrical bus that feeds the
transformers. Additionally,

triplen (3rd, 9th, 15th and
so on) harmonic currents
generated by the loads will
be treated in the secondary
windings of HMTs. This will
ensure that these currents
will not circulate in the
primary of the transformer
creating additional heat,
voltage distortion and wasted
energy loss. When using
two or more transformers to
treat harmonics, it is better
that the load be split equally
between the transformers
to receive the
maximum benefit.

Electrical Bus

The combination of a Type
POS (+15° phase-shift)
transformer and a Type NEG
(–15° phase-shift) transformer
effectively treats 5th, 7th,
17th and 19th harmonic
currents. These harmonic
currents are canceled in the
common electrical bus that
feeds the transformers.
Additionally, triplen (3rd, 9th,
15th and so on) harmonic

2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-92

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Type POS

currents generated by the
loads connected to these
transformers will be treated in
their secondary windings due
to their low zero sequence
impedance. When using two
or more transformers to treat
harmonics, it is better that the
load be split equally between
the transformers to receive
the maximum benefit.

Transformers
General-Purpose Encapsulated Transformers

2.4

Contents

Type EP 3–25 kVA

Description

Page

General-Purpose Encapsulated Transformers
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . .
Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications. . . . . . . . . . .

V2-T2-94
V2-T2-94
V2-T2-94
V2-T2-100
V2-T2-109
V2-T2-109

2
2
2
2
2
2
2
2
2
2

Product Description

Application Description

Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.

The basic purpose of a
transformer is voltage
transformation as near as
practically possible to the load
for economy and distribution
of power. Typical loads for
dry-type distribution
transformers include lighting,
heating, air conditioners,
fans and machine tools.
Such loads are found in
commercial, institutional,
industrial and residential
structures.

Type EP and EPT
●
●

●

●

●

●
●

●

Encapsulated design
Suitable for indoor or
outdoor applications
Totally enclosed, nonventilated enclosures
Enclosures are
NEMA 3R rated
Mountable in any position
indoors and upright-only
outdoors
180ºC insulation system
115ºC rise standard;
80°C optional
Available in ratings through
37.5 kVA single-phase;
75 kVA three-phase

Features, Benefits
and Functions
●

●

●

60 Hz operation
(50/60 Hz optional)
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels

2

Standards and
Certifications
●
●

2

UL listed
CSA certified

2
2
2

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA,
ANSI and IEEE Standards.
All 600 volt class transformers
are UL listed unless otherwise
noted.

2
2
2
2
2

Seismically Qualified
Eaton manufactured dry-type
distribution transformers are
seismically qualified and
exceed requirements of
the Uniform Building Code
(UBC), International Building
Code (IBC), and California
Code Title 24.

2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-93

2.4
2
2
2
2
2

Transformers
General-Purpose Encapsulated Transformers

Catalog Number Selection
Please refer to Section 2.7 Page V2-T2-187.

Product Selection
Additional Product Selection information begins on Page V2-T2-189.

Single-Phase Encapsulated—Type EP, 60 Hz

Type EP 3–37.5 kVA

2

120 x 240 Volts to 120/240 Volts 1
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

0.5

—

—

EP

115

FR57P

3E

16 (7)

Indoor–Outdoor

S10N11P51P

2

1

—

—

EP

115

FR67P

3E

31 (14)

Indoor–Outdoor

S10N11P01P

1.5

—

—

EP

115

FR67P

3E

42 (19)

Indoor–Outdoor

S10N11P16P

2

2

—

—

EP

115

FR68P

3E

42 (19)

Indoor–Outdoor

S10N11P02P

3

—

—

EP

115

FR176

3E

55 (25)

Indoor–Outdoor

S10N11S03N

2

5

—

—

EP

115

FR177

3E

113 (51)

Indoor–Outdoor

S10N11S05N

2

7.5

—

—

EP

115

FR178

3E

123 (56)

Indoor–Outdoor

S10N11S07N

10

—

—

EP

115

FR179

3E

193 (88)

Indoor–Outdoor

S10N11S10N

15

—

—

EP

115

FR180

3E

216 (98)

Indoor–Outdoor

S10N11S15N

25

—

—

EP

115

FR182

3E

375 (170)

Indoor–Outdoor

S10N11S25N

2
2
2

208 Volts to 120/240 Volts 1

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

0.5

—

—

EP

115

FR57P

26A

16 (7)

Indoor–Outdoor

S29N11P51P

2

1

—

—

EP

115

FR67P

26A

31 (14)

Indoor–Outdoor

S29N11P01P

2

1.5

—

—

EP

115

FR67P

26A

42 (19)

Indoor–Outdoor

S29N11P16P

2

—

—

EP

115

FR68P

26A

42 (19)

Indoor–Outdoor

S29N11P02P

2

3

—

—

EP

115

FR176

26A

65 (30)

Indoor–Outdoor

S29N11S03N

5

—

—

EP

115

FR177

26A

113 (51)

Indoor–Outdoor

S29N11S05N

2

7.5

—

—

EP

115

FR178

26A

123 (56)

Indoor–Outdoor

S29N11S07N

10

—

—

EP

115

FR179

26A

193 (88)

Indoor–Outdoor

S29N11S10N

15

—

—

EP

115

FR180

26A

216 (98)

Indoor–Outdoor

S29N11S15N

25

—

—

EP

115

FR182

26A

395 (179)

Indoor–Outdoor

S29N11S25N

Full Capacity Taps

2
2

Notes
1 Contact Eaton for availability of 0.05–0.25 kVA designs.

2

Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including
stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
V2-T2-94

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.4

Transformers
General-Purpose Encapsulated Transformers

Single-Phase Encapsulated—Type EP, 60 Hz

2
2

277 Volts to 120/240 Volts 1
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

0.5

—

—

EP

115

FR58AP

524A

26 (12)

Indoor–Outdoor

S27N11P51P

1

—

—

EP

115

FR59AP

524A

31 (14)

Indoor–Outdoor

S27N11P01P

1.5

—

—

EP

115

FR67P

524A

42 (19)

Indoor–Outdoor

S27N11P16P

2

—

—

EP

115

FR176P

524A

65 (30)

Indoor–Outdoor

S27N11P02P

3

—

—

EP

115

FR176

524A

55 (25)

Indoor–Outdoor

S27N11S03N

5

—

—

EP

115

FR177

524A

113 (51)

Indoor–Outdoor

S27N11S05N

7.5

—

—

EP

115

FR178

524A

123 (56)

Indoor–Outdoor

S27N11S07N

10

—

—

EP

115

FR179

524A

193 (88)

Indoor–Outdoor

S27N11S10N

15

—

—

EP

115

FR180

524A

180 (82)

Indoor–Outdoor

S27N11S15N

25

—

—

EP

115

FR182

524A

375 (170)

Indoor–Outdoor

S27N11S25N

2
2
2
2
2
2
2
2

240 x 480 Volts to 120/240 Volts
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

0.050

—

—

EP

115

FR52

3A

7 (3)

Indoor–Outdoor

S20N11S81N

0.075

—

—

EP

115

FR54

3A

7 (3)

Indoor–Outdoor

S20N11S85N

0.100

—

—

EP

115

FR54

3A

7 (3)

Indoor–Outdoor

S20N11S82N

0.150

—

—

EP

115

FR55

3A

8 (4)

Indoor–Outdoor

S20N11S83N

0.25

—

—

EP

115

FR57P

3A

12 (5)

Indoor–Outdoor

S20N11P26P

0.5

—

—

EP

115

FR57P

3A

16 (7)

Indoor–Outdoor

S20N11P51P

0.75

—

—

EP

115

FR58AP

3A

26 (12)

Indoor–Outdoor

S20N11P76P

1

—

—

EP

115

FR67P

3A

31 (14)

Indoor–Outdoor

S20N11P01P

1.5

—

—

EP

115

FR67P

3A

42 (19)

Indoor–Outdoor

S20N11P16P

2

—

—

EP

115

FR68P

3A

42 (19)

Indoor–Outdoor

S20N11P02P

3

—

—

EP

115

FR176

3A

65 (30)

Indoor–Outdoor

S20N11S03N

3

2

2

EP

115

FR176

3A

65 (30)

Indoor–Outdoor

S20K11S03N

5

—

—

EP

115

FR177

3A

113 (51)

Indoor–Outdoor

S20N11S05N

5

2

2

EP

115

FR177

9A

105 (48)

Indoor–Outdoor

S20K11S05N

7.5

—

—

EP

115

FR178

3A

105 (48)

Indoor–Outdoor

S20N11S07N

7.5

2

2

EP

115

FR178

9A

123 (56)

Indoor–Outdoor

S20K11S07N

10

—

—

EP

115

FR179

3A

193 (88)

Indoor–Outdoor

S20N11S10N

10

2

2

EP

115

FR179

9A

193 (88)

Indoor–Outdoor

S20K11S10N

15

—

—

EP

115

FR180

3A

216 (98)

Indoor–Outdoor

S20N11S15N

15

3

3

EP

115

FR180

23A

216 (98)

Indoor–Outdoor

S20L11S15N

25

—

—

EP

115

FR182

3A

385 (175)

Indoor–Outdoor

S20N11S25N

25

3

3

EP

115

FR182

23A

375 (170)

Indoor–Outdoor

S20L11S25N

37.5

3

3

EP

115

FR300A

248A

735 (334)

Indoor–Outdoor

S20L11S37 4

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Contact Eaton for availability of 0.05–0.25 kVA designs.
2 1 at +10% FCBN at 240 volts; 2 at –5% FCBN at 480 volts.
3 2 at +5% FCBN at 240 volts; 4 at –2.5% FCBN at 480 volts.
4 Floor-mount only.

2

Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-95

2.4
2

Transformers
General-Purpose Encapsulated Transformers

Single-Phase Encapsulated—Type EP, 60 Hz

2

190/200/208/220 x 380/400/416/440 Volts to 110/220 Volts 50/60 Hz—Export Model IP 22 Rated

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

0.5

—

—

EP

115

FR67

538A

42 (19)

Indoor–Outdoor

S40N14S51CE

1

—

—

EP

115

FR67

538A

42 (19)

Indoor–Outdoor

S40N14S01CE

1.5

—

—

EP

115

FR176

538A

65 (30)

Indoor–Outdoor

S40N14S16CE

2

2

—

—

EP

115

FR176

538A

65 (30)

Indoor–Outdoor

S40N14S02CE

3

—

—

EP

115

FR177

538A

113 (51)

Indoor–Outdoor

S40N14S03CE

2

5

—

—

EP

115

FR178

538A

140 (64)

Indoor–Outdoor

S40N14S05CE

7.5

—

—

EP

115

FR179

538A

193 (88)

Indoor–Outdoor

S40N14S07CE

10

—

—

EP

115

FR180

538A

216 (98)

Indoor–Outdoor

S40N14S10CE

15

—

—

EP

115

FR182

538A

375 (170)

Indoor–Outdoor

S40N14S15CE

2
2

2
2

Full Capacity Taps

2

120/208/240/277 Volts to 120/240 Volts 60 Hz

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

1

—

—

EP

115

FR67P

1

42 (19)

Indoor–Outdoor

S54N11P01

2

Full Capacity Taps

1.5

—

—

EP

115

FR176P

1

65 (30)

Indoor–Outdoor

S54N11P16

2

2

—

—

EP

115

FR176P

1

65 (30)

Indoor–Outdoor

S54N11P02

—

—

EP

115

FR177

1

2

3

113 (51)

Indoor–Outdoor

S54N11S03

5

—

—

EP

115

FR178

1

140 (64)

Indoor–Outdoor

S54N11S05

2

7.5

—

—

EP

115

FR179

1

193 (88)

Indoor–Outdoor

S54N11S07

10

—

—

EP

115

FR180

1

216 (98)

Indoor–Outdoor

S54N11S10

2
2

240 x 480 Volts to 120/240 Volts Stainless Steel 2

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

—

EP

115

FR176

3A

65 (30)

Indoor–Outdoor

S20N11S03SS

2

5

—

—

EP

115

FR177

3A

113 (51)

Indoor–Outdoor

S20N11S05SS

2

7.5

—

—

EP

115

FR178

3A

123 (56)

Indoor–Outdoor

S20N11S07SS

10

—

—

EP

115

FR179

3A

193 (88)

Indoor–Outdoor

S20N11S10SS

15

—

—

EP

115

FR180

3A

205 (93)

Indoor–Outdoor

S20N11S15SS

25

—

—

EP

115

FR182

3A

375 (170)

Indoor–Outdoor

S20N11S25SS

2
2
2
2

Full Capacity Taps

Notes
1 Refer to your local Eaton sales office.
2 NEMA 3R, 304 stainless steel enclosure; 316 stainless steel enclosure available as an option.
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
V2-T2-96

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.4

Transformers
General-Purpose Encapsulated Transformers

Single-Phase Encapsulated—Type EP, 60 Hz

2
2

480 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

1

—

2 at –5%

EP

115

FR67P

2D

31 (14)

Indoor–Outdoor

S48G11P01P

1.5

—

2 at –5%

EP

115

FR67P

2D

42 (19)

Indoor–Outdoor

S48G11P16P

2

—

2 at –5%

EP

115

FR68P

2D

42 (19)

Indoor–Outdoor

S48G11P02P

3

—

2 at –5%

EP

115

FR176

2D

65 (30)

Indoor–Outdoor

S48G11S03N

3

2 at +2.5%

2 at –2.5%

EP

115

FR176

16A

65 (30)

Indoor–Outdoor

S48D11S03N

5

—

2 at –5%

EP

115

FR177

2D

113 (51)

Indoor–Outdoor

S48G11S05N

5

2 at +2.5%

2 at –2.5%

EP

115

FR177

16A

113 (51)

Indoor–Outdoor

S48D11S05N

7.5

—

2 at –5%

EP

115

FR178

2D

123 (56)

Indoor–Outdoor

S48G11S07N

7.5

2 at +2.5%

2 at –2.5%

EP

115

FR178

16A

123 (56)

Indoor–Outdoor

S48D11S07N

10

—

2 at –5%

EP

115

FR179

2D

193 (88)

Indoor–Outdoor

S48G11S10N

10

2 at +2.5%

2 at –2.5%

EP

115

FR179

16A

193 (88)

Indoor–Outdoor

S48D11S10N

15

—

2 at –5%

EP

115

FR180

2D

216 (98)

Indoor–Outdoor

S48G11S15N

15

2 at +2.5%

2 at –2.5%

EP

115

FR180

16A

216 (98)

Indoor–Outdoor

S48D11S15N

25

—

2 at –5%

EP

115

FR182

2D

385 (175)

Indoor–Outdoor

S48G11S25N

25

2 at +2.5%

4 at –2.5%

EP

115

FR132

83A

410 (186)

Indoor–Outdoor

S48M11S25N

2
2
2
2
2
2
2
2
2
2
2

480 Volts to 120/240 Volts Stainless Steel, Copper Windings 1
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

10

2 at +2.5%

2 at –2.5%

EP

115

FR179

16A

210 (95)

Indoor–Outdoor

S48D11S10CUSS

15

2 at +2.5%

2 at –2.5%

EP

115

FR180

16A

235 (107)

Indoor–Outdoor

S48D11S15SSCU

25

2 at +2.5%

4 at –2.5%

EP

115

FR182

83A

415 (188)

Indoor–Outdoor

S48M11S25SSCU

2
2
2
2

600 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

0.5

—

2 at –5%

EP

115

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

FR57P

2I

16 (7)

Indoor–Outdoor

S60G11P51P

0.75

—

2 at –5%

EP

115

FR58AP

2I

26 (12)

Indoor–Outdoor

S60G11P76P

1

—

2 at –5%

EP

115

FR67P

2I

31 (14)

Indoor–Outdoor

S60G11P01P

1.5

—

2 at –5%

EP

115

FR67P

2I

42 (19)

Indoor–Outdoor

S60G11P16P

2

—

2 at –5%

EP

115

FR68P

2I

42 (19)

Indoor–Outdoor

S60G11P02P

3

—

2 at –5%

EP

115

FR176

2I

65 (30)

Indoor–Outdoor

S60G11S03N

5

—

2 at –5%

EP

115

FR177

2I

105 (48)

Indoor–Outdoor

S60G11S05N

7.5

—

2 at –5%

EP

115

FR178

2I

123 (56)

Indoor–Outdoor

S60G11S07N

10

—

2 at –5%

EP

115

FR179

2I

193 (88)

Indoor–Outdoor

S60G11S10N

15

—

4 at –2.5%

EP

115

FR180

527A

216 (98)

Indoor–Outdoor

S60J11S15N

25

—

4 at –2.5%

EP

115

FR182

527A

385 (175)

Indoor–Outdoor

S60J11S25N

25

2 at +2.5%

4 at –2.5%

EP

115

FR132

83B

395 (180)

Indoor–Outdoor

S60M11S25N

2
2
2
2
2
2
2
2

Notes
1 NEMA 3R, 304 stainless steel enclosure; 316 stainless steel enclosure available as an option.

2

Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-97

2.4
2

Transformers
General-Purpose Encapsulated Transformers

Single-Phase Shielded—Type EP, 60 Hz

2

120 x 240 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

—

EP

115

FR176

90B

50 (23)

Indoor–Outdoor

S10N11E03N
S10N11E05N

2
2
2
2

Full Capacity Taps

5

—

—

EP

115

FR177

90B

90 (41)

Indoor–Outdoor

7.5

—

—

EP

115

FR178

90B

123 (56)

Indoor–Outdoor

S10N11E07N

10

—

—

EP

115

FR179

90B

210 (95)

Indoor–Outdoor

S10N11E10N

15

—

—

EP

115

FR180

90B

205 (93)

Indoor–Outdoor

S10N11E15N

25

—

—

EP

115

FR182

90B

375 (170)

Indoor–Outdoor

S10N11E25N

2

120 Volts to 120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

—

EP

115

FR176

77A

60 (27)

Indoor–Outdoor

S12N12E03N

2

5

—

—

EP

115

FR177

77A

100 (45)

Indoor–Outdoor

S12N12E05N

7.5

—

—

EP

115

FR178

77A

123 (56)

Indoor–Outdoor

S12N12E07N

2

10

—

—

EP

115

FR179

77A

180 (82)

Indoor–Outdoor

S12N12E10N

15

—

—

EP

115

FR180

77A

216 (98)

Indoor–Outdoor

S12N12E15N

25

—

—

EP

115

FR182

77A

375 (170)

Indoor–Outdoor

S12N12E25N

2

2
2
2
2

Full Capacity Taps

208 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

—

EP

115

FR176

578A

60 (27)

Indoor–Outdoor

S29N11E03N

2

5

—

—

EP

115

FR177

578A

135 (61)

Indoor–Outdoor

S29N11E05N

7.5

—

—

EP

115

FR178

578A

95 (43)

Indoor–Outdoor

S29N11E07N

2

10

—

—

EP

115

FR179

578A

165 (75)

Indoor–Outdoor

S29N11E10N

15

—

—

EP

115

FR180

578A

185 (94)

Indoor–Outdoor

S29N11E15N

25

—

—

EP

115

FR182

578A

375 (170)

Indoor–Outdoor

S29N11E25N

2
2
2
2
2
2
2
2
2

208 Volts to 208 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

—

EP

115

FR176

77B

65 (30)

Indoor–Outdoor

S29N29E03N

5

—

—

EP

115

FR177

77B

113 (51)

Indoor–Outdoor

S29N29E05N

7.5

—

—

EP

115

FR178

77B

123 (56)

Indoor–Outdoor

S29N29E07N

10

—

—

EP

115

FR179

77B

195 (89)

Indoor–Outdoor

S29N29E10N

15

—

—

EP

115

FR180

77B

216 (98)

Indoor–Outdoor

S29N29E15N

25

—

—

EP

115

FR182

77B

375 (170)

Indoor–Outdoor

S29N29E25N

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
V2-T2-98

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.4

Transformers
General-Purpose Encapsulated Transformers

Single-Phase Shielded—Type EP, 60 Hz

2
2

240 Volts to 240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

2

Catalog Number

3

—

—

EP

115

FR176

77C

65 (30)

Indoor–Outdoor

S24N24E03N

5

—

—

EP

115

FR177

77C

113 (51)

Indoor–Outdoor

S24N24E05N

7.5

—

—

EP

115

FR178

77C

123 (56)

Indoor–Outdoor

S24N24E07N

10

—

—

EP

115

FR179

77C

193 (88)

Indoor–Outdoor

S24N24E10N

15

—

—

EP

115

FR180

77C

216 (98)

Indoor–Outdoor

S24N24E15N

25

—

—

EP

115

FR182

77C

375 (170)

Indoor–Outdoor

S24N24E25N

2
2
2
2
2

277 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

—

EP

115

FR176

513B

65 (30)

Indoor–Outdoor

S27N11E03N

5

—

—

EP

115

FR177

513B

113 (51)

Indoor–Outdoor

S27N11E05N

7.5

—

—

EP

115

FR178

513B

75 (34)

Indoor–Outdoor

S27N11E07N

10

—

—

EP

115

FR179

513B

162 (74)

Indoor–Outdoor

S27N11E10N

15

—

—

EP

115

FR180

513B

216 (98)

Indoor–Outdoor

S27N11E15N

25

—

—

EP

115

FR182

513B

375 (170)

Indoor–Outdoor

S27N11E25N

2
2
2
2
2
2

240 x 480 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

0.25

—

—

EP

115

FR57P

90A

12 (5)

Indoor–Outdoor

S20N11E26P

0.50

—

—

EP

115

FR57P

90A

16 (7)

Indoor–Outdoor

S20N11E51P

0.75

—

—

EP

115

FR58AP

90A

26 (12)

Indoor–Outdoor

S20N11E76P

1

—

—

EP

115

FR67P

90A

31 (14)

Indoor–Outdoor

S20N11E01P

1.5

—

—

EP

115

FR67P

90A

42 (19)

Indoor–Outdoor

S20N11E16P

2

—

—

EP

115

FR68P

90A

42 (19)

Indoor–Outdoor

S20N11E02P

3

—

—

EP

115

FR176

90A

65 (30)

Indoor–Outdoor

S20N11E03A

5

—

—

EP

115

FR177

90A

113 (51)

Indoor–Outdoor

S20N11E05A

7.5

—

—

EP

115

FR178

90A

123 (56)

Indoor–Outdoor

S20N11E07A

10

—

—

EP

115

FR179

90A

166 (75)

Indoor–Outdoor

S20N11E10A

15

—

—

EP

115

FR180

90A

216 (98)

Indoor–Outdoor

S20N11E15A

25

1

1

EP

115

FR182

526A

375 (170)

Indoor–Outdoor

S20L11E25A

2
2
2
2
2
2
2
2
2

Notes
1 2 at +5% FCBN at 240 volts; 4 at –2.5% FCBN at 480 volts.
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-99

2.4
2

Transformers
General-Purpose Encapsulated Transformers

Three-Phase Encapsulated—Type EPT, 60 Hz

2

240 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

9

—

2 at –5%

EPT

115

FR103

70C

190 (86)

Indoor–Outdoor

Y24G28T09N 1

15

—

2 at –5%

EPT

115

FR95

70C

275 (125)

Indoor–Outdoor

Y24G28T15N 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84C

422 (191)

Indoor–Outdoor

Y24M28T30N

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84C

660 (299)

Indoor–Outdoor

Y24M28T45N

2
2
2

Full Capacity Taps

Catalog Number

2

380 Delta Volts to 190Y/110 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

3

—

2 at –5%

EPT

115

FR201

70F

116 (53)

Indoor–Outdoor

Y38G19T03A 1

2

6

—

2 at –5%

EPT

115

FR200

70F

165 (75)

Indoor–Outdoor

Y38G19T06A 1

9

—

2 at –5%

EPT

115

FR95

70F

275 (125)

Indoor–Outdoor

Y38G19T09A 1

2

15

—

2 at –5%

EPT

115

FR95

72R

275 (125)

Indoor–Outdoor

Y38G19T15A 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84AC

422 (191)

Indoor–Outdoor

Y38M19T30A

2

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84AC

660 (299)

Indoor–Outdoor

Y38M19T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84AC

1275 (580)

Indoor–Outdoor

Y38M19T75A 2

Catalog Number

Full Capacity Taps

2
2

380 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

2

3

—

2 at –5%

EPT

115

FR201

70D

116 (53)

Indoor–Outdoor

Y38G28T03A 1

6

—

2 at –5%

EPT

115

FR200

70F

165 (75)

Indoor–Outdoor

Y38G28T06A 1

2

9

—

2 at –5%

EPT

115

FR103

70D

185 (84)

Indoor–Outdoor

Y38G28T09A 1

15

—

2 at –5%

EPT

115

FR95

70D

275 (125)

Indoor–Outdoor

Y38G28T15A 1

2

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84H

422 (191)

Indoor–Outdoor

Y38M28T30A

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84R

660 (299)

Indoor–Outdoor

Y38M28T45A

2

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84R

1275 (580)

Indoor–Outdoor

Y38M28T75A 2

2

Notes
1 T-T (Scott T) connected secondary.
2 Floor-mount only.

2

Full Capacity Taps

Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-100

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.4

Transformers
General-Purpose Encapsulated Transformers

Three-Phase Encapsulated—Type EPT, 60 Hz

2
2

380 Delta Volts to 220Y/127 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

2

Catalog Number

3

—

2 at –5%

EPT

115

FR201

70F

116 (53)

Indoor–Outdoor

Y38G31T03A 1

6

—

2 at –5%

EPT

115

FR200

70F

165 (75)

Indoor–Outdoor

Y38G31T06A 1

9

—

2 at –5%

EPT

115

FR103

70M

195 (89)

Indoor–Outdoor

Y38G31T09A 1

15

—

2 at –5%

EPT

115

FR95

70F

275 (125)

Indoor–Outdoor

Y38G31T15A 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84R

422 (191)

Indoor–Outdoor

Y38M31T30A

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84R

660 (299)

Indoor–Outdoor

Y38M31T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84R

1275 (580)

Indoor–Outdoor

Y38M31T75A 2

2
2
2
2
2
2

380 Delta Volts to 220 Delta Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

2 at –5%

EPT

115

FR201

74K

116 (53)

Indoor–Outdoor

Y38G25T03A 1

6

—

2 at –5%

EPT

115

FR200

74K

180 (82)

Indoor–Outdoor

Y38G25T06A 1

9

—

2 at –5%

EPT

115

FR103

74K

195 (89)

Indoor–Outdoor

Y38G25T09A 1

15

—

2 at –5%

EPT

115

FR95

74K

275 (125)

Indoor–Outdoor

Y38G25T15A 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

3

422 (191)

Indoor–Outdoor

Y38M25T30A

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

3

660 (299)

Indoor–Outdoor

Y38M25T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

3

1275 (580)

Indoor–Outdoor

Y38M25T75A 2

2
2
2
2
2

380 Delta Volts to 380Y/220 Volts
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

2 at –5%

EPT

115

FR201

70D

116 (53)

Indoor–Outdoor

Y38G37T03A 1

6

—

2 at –5%

EPT

115

FR200

70D

165 (75)

Indoor–Outdoor

Y38G37T06A 1

9

—

2 at –5%

EPT

115

FR103

70D

180 (82)

Indoor–Outdoor

Y38G37T09A 1

15

—

2 at –5%

EPT

115

FR95

70D

275 (125)

Indoor–Outdoor

Y38G37T15A 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84H

422 (191)

Indoor–Outdoor

Y38M37T30A

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84H

660 (299)

Indoor–Outdoor

Y38M37T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84H

1275 (580)

Indoor–Outdoor

Y38M37T75A 2

kVA

FCAN

FCBN

Type

2
2
2
2
2
2

380 Delta Volts to 480Y/277 Volts
Full Capacity Taps

2

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

2 at –5%

EPT

115

FR201

70F

116 (53)

Indoor–Outdoor

Y38G47T03A 1

6

—

2 at –5%

EPT

115

FR200

70F

180 (82)

Indoor–Outdoor

Y38G47T06A 1

9

—

2 at –5%

EPT

115

FR103

70F

166 (75)

Indoor–Outdoor

Y38G47T09A 1

15

—

2 at –5%

EPT

115

FR95

70F

275 (125)

Indoor–Outdoor

Y38G47T15A 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84AB

422 (191)

Indoor–Outdoor

Y38M47T30A

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84AB

660 (299)

Indoor–Outdoor

Y38M47T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84AB

1275 (580)

Indoor–Outdoor

Y38M47T75A 2

2
2
2
2
2
2

Notes
1 T-T (Scott T) connected secondary.
2 Floor-mount only.
3 Refer to your Eaton sales office.

2

Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-101

2

2.4
2

Transformers
General-Purpose Encapsulated Transformers

Three-Phase Encapsulated—Type EPT, 60 Hz

2

416 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

3

—

2 at –5%

EPT

115

FR201

70V

116 (53)

Indoor–Outdoor

Y43G28T03A 1

6

—

2 at –5%

EPT

115

FR200

70V

175 (79)

Indoor–Outdoor

Y43G28T06A 1

9

—

2 at –5%

EPT

115

FR103

70V

190 (86)

Indoor–Outdoor

Y43G28T09A 1

15

—

2 at –5%

EPT

115

FR95

70V

275 (125)

Indoor–Outdoor

Y43G28T15A 1

2
2
2
2
2
2

Full Capacity Taps

Catalog Number

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84I

422 (191)

Indoor–Outdoor

Y43M28T30A

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84I

660 (299)

Indoor–Outdoor

Y43M28T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84I

1275 (580)

Indoor–Outdoor

Y43M28T75A 2

440 Delta Volts to 220Y/127 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

2 at –5%

EPT

115

FR201

70G

116 (53)

Indoor–Outdoor

Y44G31T03A 1

2

6

—

2 at –5%

EPT

115

FR200

70G

165 (75)

Indoor–Outdoor

Y44G31T06A 1

9

—

2 at –5%

EPT

115

FR103

70G

166 (75)

Indoor–Outdoor

Y44G31T09A 1

2

15

—

2 at –5%

EPT

115

FR95

70G

275 (125)

Indoor–Outdoor

Y44G31T15A 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84O

422 (191)

Indoor–Outdoor

Y44M31T30A 2

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84O

660 (299)

Indoor–Outdoor

Y44M31T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84O

1275 (580)

Indoor–Outdoor

Y44M31T75A 2

2

2
2
2

480 Delta Volts to 208Y/120 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

3

—

2 at –5%

EPT

115

FR201

70A

116 (52)

Indoor–Outdoor

Y48G28T03N 1

6

—

2 at –5%

EPT

115

FR200

70A

165 (75)

Indoor–Outdoor

Y48G28T06N 1

2

6

2 at +2.5%

2 at –2.5%

EPT

115

FR200

72B

165 (75)

Indoor–Outdoor

Y48D28T06N 1

9

—

2 at –5%

EPT

115

FR103

70A

166 (75)

Indoor–Outdoor

Y48G28T09N 1

2

9

—

4 at –2.5%

EPT

115

FR103

503A

185 (84)

Indoor–Outdoor

Y48J28T09N 1

9

2 at +2.5%

2 at –2.5%

EPT

115

FR103

72B

185 (84)

Indoor–Outdoor

Y48D28T09N 1

2

15

—

2 at –5%

EPT

115

FR95

70A

275 (125)

Indoor–Outdoor

Y48G28T15N 1

2

15

—

4 at –2.5%

EPT

115

FR95

503A

275 (125)

Indoor–Outdoor

Y48J28T15N 1

15

2 at +2.5%

2 at –2.5%

EPT

115

FR95

72B

275 (125)

Indoor–Outdoor

Y48D28T15N 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84A

422 (191)

Indoor–Outdoor

Y48M28T30N

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84A

720 (327)

Indoor–Outdoor

Y48M28T45N

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84A

1275 (580)

Indoor–Outdoor

Y48M28T75N 2

Catalog Number

2
2

Full Capacity Taps

2

480 Delta Volts to 208Y/120 Volts—Copper Windings

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

15

2 at +2.5%

2 at –2.5%

EPT

115

FR95

72B

300 (136)

Indoor–Outdoor

Y48D28T15CU 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84A

505 (230)

Indoor–Outdoor

Y48M28T30CU

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84A

810 (368)

Indoor–Outdoor

Y48M28T45CU

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84A

1450 (659)

Indoor–Outdoor

Y48M28T75CU 23

2
2
2
2
2

Full Capacity Taps

Notes
1 T-T (Scott T) connected secondary.
2 Floor-mount only.
3 Not CSA certified.
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.
V2-T2-102

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.4

Transformers
General-Purpose Encapsulated Transformers

Three-Phase Encapsulated—Type EPT, 60 Hz

2
2

480 Delta Volts to 208Y/120 Volts Stainless Steel 1
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

3

—

2 at –5%

EPT

115

FR201

70A

6

2 at +2.5%

2 at –2.5%

EPT

115

FR200

72B

Weight
Lbs (kg)

Weathershield

Catalog Number

116 (53)

Indoor–Outdoor

Y48G28T03SS 2

175 (79)

Indoor–Outdoor

Y48D28T06SS 2

9

2 at +2.5%

2 at –2.5%

EPT

115

FR103

72B

185 (84)

Indoor–Outdoor

Y48D28T09SS 2

15

2 at +2.5%

2 at –2.5%

EPT

115

FR95

72B

275 (125)

Indoor–Outdoor

Y48D28T15SS 2

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84A

422 (191)

Indoor–Outdoor

Y48M28T30SS

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84A

660 (299)

Indoor–Outdoor

Y48M28T45SS

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84A

1275 (580)

Indoor–Outdoor

Y48M28T75SS 3

2
2
2
2
2
2
2

480 Delta Volts to 208Y/120 Volts Stainless Steel—Copper Windings 1
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

2 at –2.5%

EPT

115

FR95

72B

275 (125)

Indoor–Outdoor

Y48D28T15CUSS 2

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84A

504 (229)

Indoor–Outdoor

Y48M28T30CUSS

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84A

810 (368)

Indoor–Outdoor

Y48M28T45CUSS

2
2
2

480 Delta Volts to 220Y/127 Volts
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

2 at –5%

EPT

115

FR201

70K

116 (53)

Indoor–Outdoor

Y48G31T03A 2

6

—

2 at –5%

EPT

115

FR200

70K

175 (79)

Indoor–Outdoor

Y48G31T06A 2

9

—

2 at –5%

EPT

115

FR103

70A

185 (84)

Indoor–Outdoor

Y48G31T09A 2

15

—

2 at –5%

EPT

115

FR95

70A

275 (125)

Indoor–Outdoor

Y48G31T15A 2

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84A

422 (191)

Indoor–Outdoor

Y48M31T30A

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84A

660 (299)

Indoor–Outdoor

Y48M31T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84K

1275 (580)

Indoor–Outdoor

Y48M31T75A 3

2
2
2
2
2
2
2

480 Delta Volts to 240 Delta Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

2 at –5%

EPT

115

FR201

74A

116 (52)

Indoor–Outdoor

Y48G24T03N 24

6

—

2 at –5%

EPT

115

FR200

74A

165 (75)

Indoor–Outdoor

Y48G24T06N 24

9

—

4 at –2.5%

EPT

115

FR103

73A

185 (84)

Indoor–Outdoor

Y48J24T09N 24

15

—

4 at –2.5%

EPT

115

FR95

73A

275 (125)

Indoor–Outdoor

Y48J24T15N 24

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

85A

422 (191)

Indoor–Outdoor

Y48M24T30N 4

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

85A

660 (299)

Indoor–Outdoor

Y48M24T45N 4

2
2
2
2
2

Notes
1 NEMA 3R, 304 stainless steel enclosure; 316 stainless steel enclosure available.
2 T-T connected secondary.
3 Floor-mount only.
4 Do not include 120 volt lighting tap.

2

Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-103

2.4
2

Transformers
General-Purpose Encapsulated Transformers

Three-Phase Encapsulated—Type EPT, 60 Hz

2

480 Delta Volts to 380Y/220 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

3

—

2 at –5%

EPT

115

FR201

70A

116 (53)

Indoor–Outdoor

Y48G37T03A 1

6

—

2 at –5%

EPT

115

FR200

70R

165 (75)

Indoor–Outdoor

Y48G37T06A 1
Y48G37T09A 1

2
2
2
2

Full Capacity Taps

Catalog Number

9

—

2 at –5%

EPT

115

FR103

70R

185 (84)

Indoor–Outdoor

15

—

2 at –5%

EPT

115

FR95

70R

275 (125)

Indoor–Outdoor

Y48G37T15A 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84A

422 (191)

Indoor–Outdoor

Y48M37T30A

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84A

660 (299)

Indoor–Outdoor

Y48M37T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84A

1275 (580)

Indoor–Outdoor

Y48M37T75A 2

2
2

480 Delta Volts to 380 Delta Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

2 at –5%

EPT

115

FR201

74B

116 (53)

Indoor–Outdoor

Y48G38T03A 1

6

—

2 at –5%

EPT

115

FR200

74B

165 (75)

Indoor–Outdoor

Y48G38T06A 1

2

9

—

2 at –5%

EPT

115

FR103

74B

185 (84)

Indoor–Outdoor

Y48G38T09A 1

15

—

2 at –5%

EPT

115

FR95

74A

275 (125)

Indoor–Outdoor

Y48G38T15A 1

2

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

85A

422 (191)

Indoor–Outdoor

Y48M38T30A

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

85A

660 (299)

Indoor–Outdoor

Y48M38T45A

2

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

85A

1275 (580)

Indoor–Outdoor

Y48M38T75A 2

2

Full Capacity Taps

2

480 Delta Volts to 416Y/240 Volts

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

2 at –5%

EPT

115

FR200

70A

165 (75)

Indoor–Outdoor

Y48G51T03A 1

6

—

2 at –5%

EPT

115

FR200

70A

185 (84)

Indoor–Outdoor

Y48G51T06A 1

9

—

2 at –5%

EPT

115

FR103

70S

185 (84)

Indoor–Outdoor

Y48G51T09A 1

15

—

2 at –5%

EPT

115

FR95

70S

275 (125)

Indoor–Outdoor

Y48G51T15A 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84A

422 (191)

Indoor–Outdoor

Y48M51T30A

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84A

660 (299)

Indoor–Outdoor

Y48M51T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84A

1275 (580)

Indoor–Outdoor

Y48M51T75A 2

2
2
2
2
2
2

Full Capacity Taps

480 Delta Volts to 440Y/254 Volts
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

2 at –5%

EPT

115

FR201

70A

116 (53)

Indoor–Outdoor

Y48G35T03A 1

2

6

—

2 at –5%

EPT

115

FR200

70A

185 (84)

Indoor–Outdoor

Y48G35T06A 1

9

—

2 at –5%

EPT

115

FR103

70A

185 (84)

Indoor–Outdoor

Y48G35T09A 1

2

15

—

2 at –5%

EPT

115

FR95

70A

275 (125)

Indoor–Outdoor

Y48G35T15A 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84A

422 (191)

Indoor–Outdoor

Y48M35T30A

2

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84A

660 (299)

Indoor–Outdoor

Y48M35T45A

75

2 at +2.5%

4 at –2.5%

EPT

115

FR245

84A

1275 (580)

Indoor–Outdoor

Y48M35T75A 2

2
2
2

Notes
1 T-T connected secondary.
2 Floor-mount only.
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
V2-T2-104

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.4

Transformers
General-Purpose Encapsulated Transformers

Three-Phase Encapsulated—Type EPT, 60 Hz

2
2

480 Delta Volts to 480Y/277 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

9

2 at +2.5%

2 at –2.5%

EPT

115

FR103

72C

190 (86)

Indoor–Outdoor

Y48D47T09N 1

15

2 at +2.5%

2 at –2.5%

EPT

115

FR95

72C

275 (125)

Indoor–Outdoor

Y48D47T15N 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84A

422 (191)

Indoor–Outdoor

Y48M47T30N

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84A

660 (299)

Indoor–Outdoor

Y48M47T45N

2
2
2
2

600 Delta Volts to 208Y/120 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

9

—

2 at –5%

EPT

115

FR103

70B

185 (84)

Indoor–Outdoor

Y60G28T09N 1

15

—

2 at –5%

EPT

115

FR95

70B

275 (125)

Indoor–Outdoor

Y60G28T15N 1

30

2 at +2.5%

4 at –2.5%

EPT

115

FR243

84B

422 (191)

Indoor–Outdoor

Y60M28T30N

45

2 at +2.5%

4 at –2.5%

EPT

115

FR244

84B

660 (299)

Indoor–Outdoor

Y60M28T45N

2
2
2
2
2

Three-Phase Shielded—Type EPT, 60 Hz

2
2

480 Delta Volts to 208Y/120 Volts
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

2 at +2.5%

2 at –2.5%

EPT

115

FR201

86B

116 (52)

Indoor–Outdoor

Y48D28E03A 1

6

2 at +2.5%

2 at –2.5%

EPT

115

FR200

86B

165 (75)

Indoor–Outdoor

Y48D28E06A 1

9

2 at +2.5%

2 at –2.5%

EPT

115

FR103

86B

190 (86)

Indoor–Outdoor

Y48D28E09N 1

15

2 at +2.5%

2 at –2.5%

EPT

115

FR95

86B

275 (125)

Indoor–Outdoor

Y48D28E15B 1

2
2
2
2
2

480 Delta Volts to 240 Delta Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

—

2 at –5%

EPT

115

FR201

88A

116 (52)

Indoor–Outdoor

Y48G24E03A 1

6

—

2 at –5%

EPT

115

FR200

88A

165 (75)

Indoor–Outdoor

Y48G24E06A 1

9

—

4 at –2.5%

EPT

115

FR103

505B

195 (89)

Indoor–Outdoor

Y48J24E09A 1

15

—

4 at –2.5%

EPT

115

FR95

505B

275 (125)

Indoor–Outdoor

Y48J24E15A 1

2
2
2
2

Notes
1 T-T connected secondary.
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-105

2.4
2

Transformers
General-Purpose Encapsulated Transformers

NEMA Type 4X Single-Phase Encapsulated—Type EP, 60 Hz, Grade 304 Stainless Steel 1

2

240 x 480 Volts to 120/240 Volts—Aluminum Windings

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

0.100 2

—

—

EP

115

FR544X

3A

7 (3)

Indoor–Outdoor

S20N11S82SS4X

2

0.015 2

—

—

EP

115

FR554X

3A

9 (4)

Indoor–Outdoor

S20N11S83SS4X

0.250 2

—

—

EP

115

FR57P4X

3A

15 (7)

Indoor–Outdoor

S20N11P26SS4X

2

0.500 2

—

—

EP

115

FR57P4X

3A

14 (6)

Indoor–Outdoor

S20N11P51SS4X

0.750 2

—

—

EP

115

FR58AP4X

3A

22 (10 )

Indoor–Outdoor

S20N11P76SS4X

2

12

—

—

EP

115

FR67P4X

3A

30 (14)

Indoor–Outdoor

S20N11P01SS4X

1.5 2

—

—

EP

115

FR67P4X

3A

41 (19)

Indoor–Outdoor

S20N11P16SS4X

2

22

—

—

EP

115

FR68P4X

3A

75 (34)

Indoor–Outdoor

S20N11P02SS4X

2

3

—

—

EP

115

FR1764X

3A

68 (31)

Indoor–Outdoor

S20N11S03SS4X

3

3

3

EP

115

FR1764X

9A

67 (30)

Indoor–Outdoor

S20K11S03SS4X

5

—

—

EP

115

FR1774X

3A

107 (49)

Indoor–Outdoor

S20N11S05SS4X

5

3

3

EP

115

FR1774X

9A

105 (48)

Indoor–Outdoor

S20K11S05SS4X

2

7.5

—

—

EP

115

FR1784X

3A

129 (58)

Indoor–Outdoor

S20N11S07SS4X

3

3

2

7.5

EP

115

FR1784X

9A

130 (59)

Indoor–Outdoor

S20K11S07SS4X

10

—

—

EP

115

FR1794X

3A

196 (89)

Indoor–Outdoor

S20N11S10SS4X

2

10

3

3

EP

115

FR1794X

9A

198 (90)

Indoor–Outdoor

S20K11S10SS4X

15

—

—

EP

115

FR1804X

3A

215 (98)

Indoor–Outdoor

S20N11S15SS4X

2

15

3

3

EP

115

FR1804X

23A

215 (98)

Indoor–Outdoor

S20L11S15SS4X

25

—

—

EP

115

FR1824X

3A

393 (178)

Indoor–Outdoor

S20N11S25SS4X

25

4

4

EP

115

FR1824X

23A

453 (206)

Indoor–Outdoor

S20L11S25SS4X

37.5

4

4

EP

115

FR300A4X

248A

735 (334)

Indoor–Outdoor

S20L11S37SS4X 5

2

2
2
2
2
2

Full Capacity Taps

Notes
1 Grade 304 stainless steel standard. Grade 316 stainless steel available as an option. Replace suffix “SS” with suffix “S6.”
2 Copper windings provided as standard.
3 1 at +10% FCBN at 240 volts; 2 at –5% FCBN at 480 volts.
4 2 at +5% FCBN at 240 volts; 4 at –2.5% FCBN at 480 volts.
5 Floor-mount only.
Contact your local Eaton sales office for voltage combinations not shown in the above table. Other voltages and custom features are available upon request.

2
2
2
2
2
2
2
2
2
2
2
V2-T2-106

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.4

Transformers
General-Purpose Encapsulated Transformers

NEMA Type 4X Single-Phase Encapsulated—Type EP, 60 Hz, Grade 304 Stainless Steel 1

2
2

240 x 480 Volts to 120/240 Volts—Copper Windings
Full Capacity Taps
kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

0.100 2

—

—

EP

115

FR544X

3A

7 (3)

Indoor–Outdoor

S20N11S82SS4X

0.015 2

—

—

EP

115

FR554X

3A

9 (4)

Indoor–Outdoor

S20N11S83SS4X

0.250 2

—

—

EP

115

FR57P4X

3A

15 (7)

Indoor–Outdoor

S20N11P26SS4X

0.500 2

—

—

EP

115

FR57P4X

3A

14 (6)

Indoor–Outdoor

S20N11P51SS4X

0.750 2

—

—

EP

115

FR58AP4X

3A

22 (10)

Indoor–Outdoor

S20N11P76SS4X

12

—

—

EP

115

FR67P4X

3A

30 (14)

Indoor–Outdoor

S20N11P01SS4X

1.5 2

—

—

EP

115

FR68P4X

3A

41 (19)

Indoor–Outdoor

S20N11P02SS4X

2
2
2
2
2

22

—

—

EP

115

FR68P4X

3A

36 (16)

Indoor–Outdoor

S20N11P16SS4X

3

—

—

EP

115

FR1764X

3A

76 (34)

Indoor–Outdoor

S20N11S03CUSS4X

3

3

3

EP

115

FR1764X

9A

77 (35)

Indoor–Outdoor

S20K11S03CUSS4X

5

—

—

EP

115

FR1774X

3A

135 (61)

Indoor–Outdoor

S20N11S05CUSS4X

5

3

3

EP

115

FR1774X

9A

121 (55)

Indoor–Outdoor

S20K11S05CUSS4X

7.5

—

—

EP

115

FR1784X

3A

144 (65)

Indoor–Outdoor

S20N11S07CUSS4X

7.5

3

3

EP

115

FR1784X

9A

146 (66)

Indoor–Outdoor

S20K11S07CUSS4X

10

—

—

EP

115

FR1794X

3A

229 (104)

Indoor–Outdoor

S20N11S10CUSS4X

10

3

3

EP

115

FR1794X

9A

219 (99)

Indoor–Outdoor

S20K11S10CUSS4X

15

—

—

EP

115

FR1804X

3A

236 (107)

Indoor–Outdoor

S20N11S15CUSS4X

15

3

3

EP

115

FR1804X

23A

236 (107)

Indoor–Outdoor

S20L11S15CUSS4X

25

—

—

EP

115

FR300A4X

3A

388 (176)

Indoor–Outdoor

S20N11S25CUSS4X

25

4

4

EP

115

FR300A4X

23A

388 (176)

Indoor–Outdoor

S20L11S25CUSS4X

37.5

4

4

EP

115

FR300A4X

248A

775 (352)

Indoor–Outdoor

S20L11S37CUSS4X 5

Notes
1 Grade 304 stainless steel standard. Grade 316 stainless steel available as an option. Replace suffix “SS” with suffix “S6.”
2 Copper windings provided as standard.
3 1 at +10% FCBN at 240 volts; 2 at –5% FCBN at 480 volts.
4 2 at +5% FCBN at 240 volts; 4 at –2.5% FCBN at 480 volts.
5 Floor-mount only.

2
2
2
2
2
2
2
2
2
2
2
2

Contact your local Eaton sales office for voltage combinations not shown in the above table. Other voltages and custom features are available upon request.

2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-107

2.4
2

Transformers
General-Purpose Encapsulated Transformers

NEMA Type 4X Three-Phase Encapsulated—Type EPT, 60 Hz, Grade 304 Stainless Steel 1

2

480 Delta Volts to 208Y/120 Volts—Aluminum Windings

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

3

—

2 at –5%

EPT

115

FR2014X

70A

125 (57)

Indoor–Outdoor

Y48G28T03SS4X 2

6

—

2 at –5%

EPT

115

FR2004X

70A

165 (75)

Indoor–Outdoor

Y48G28T06SS4X 2

6

2 at +2.5%

2 at –2.5%

EPT

115

FR2004X

72B

171 (78)

Indoor–Outdoor

Y48D28T06SS4X 2

2

9

—

2 at –5%

EPT

115

FR1034X

70A

180 (82)

Indoor–Outdoor

Y48G28T09SS4X 2

9

—

4 at –2.5%

EPT

115

FR1034X

503A

192 (87)

Indoor–Outdoor

Y48J28T09SS4X 2

2

9

2 at +2.5%

2 at –2.5%

EPT

115

FR1034X

72B

196 (89)

Indoor–Outdoor

Y48D28T09SS4X 2

15

2 at +2.5%

2 at –2.5%

EPT

115

FR954X

72B

281 (127)

Indoor–Outdoor

Y48D28T15SS4X 2

2

15

—

2 at –5%

EPT

115

FR954X

70A

269 (122)

Indoor–Outdoor

Y48G28T15SS4X 2

2

15

—

4 at –2.5%

EPT

115

FR954X

503A

268 (121)

Indoor–Outdoor

Y48J28T15SS4X 2

30

2 at +2.5%

4 at –2.5%

EPT

115

FR2434X

84A

539 (245)

Indoor–Outdoor

Y48M28T30SS4X

45

2 at +2.5%

4 at –2.5%

EPT

115

FR2444X

84A

723 (328)

Indoor–Outdoor

Y48M28T45SS4X

75

2 at +2.5%

4 at –2.5%

EPT

115

FR2454X

84A

1277 (580)

Indoor–Outdoor

Y48M28T75SS4X 3

Catalog Number

2
2

2

Full Capacity Taps

Catalog Number

2
2

480 Delta Volts to 208Y/120 Volts—Copper Windings

2

kVA

FCAN

FCBN

Type

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

2

3

—

2 at –5%

EPT

115

FR2014X

70A

139 (63)

Indoor–Outdoor

Y48G28T03CUSS4X 2

6

—

2 at –5%

EPT

115

FR2004X

70A

187 (84)

Indoor–Outdoor

Y48G28T06CUSS4X 2

2

6

2 at +2.5%

2 at –2.5%

EPT

115

FR2004X

72B

188 (85)

Indoor–Outdoor

Y48D28T06CUSS4X 2

9

—

2 at –5%

EPT

115

FR1034X

70A

226 (103)

Indoor–Outdoor

Y48G28T09CUSS4X 2

2

9

—

4 at –2.5%

EPT

115

FR1034X

503A

226 (103)

Indoor–Outdoor

Y48J28T09CUSS4X 2

9

2 at +2.5%

2 at –2.5%

EPT

115

FR1034X

72B

231 (105)

Indoor–Outdoor

Y48D28T09CUSS4X 2

2

15

2 at +2.5%

2 at –2.5%

EPT

115

FR954X

72B

276 (125)

Indoor–Outdoor

Y48D28T15CUSS4X 2

2

15

—

2 at –5%

EPT

115

FR954X

70A

283 (128)

Indoor–Outdoor

Y48G28T15CUSS4X 2

15

—

4 at –2.5%

EPT

115

FR954X

503A

299 (136)

Indoor–Outdoor

Y48J28T15CUSS4X 2

2

30

2 at +2.5%

4 at –2.5%

EPT

115

FR2434X

84A

602 (273)

Indoor–Outdoor

Y48M28T30CUSS4X

45

2 at +2.5%

4 at –2.5%

EPT

115

FR2444X

84A

829 (376)

Indoor–Outdoor

Y48M28T45CUSS4X

2

75

2 at +2.5%

4 at –2.5%

EPT

115

FR2454X

84A

1452 (659)

Indoor–Outdoor

Y48M28T75CUSS4X 3

2
2

Full Capacity Taps

Notes
1 Grade 304 stainless steel standard. Grade 316 stainless steel available as an option. Replace suffix “SS” with suffix “S6.”
2 T-T connected (Scott T) secondary winding configuration.
3 Floor-mount only.
Contact your local Eaton sales office for voltage combinations not shown in the above table. Other voltages and custom features are available upon request.

2
2
2
2
2
2
2
2
V2-T2-108

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.4

Transformers
General-Purpose Encapsulated Transformers

Accessories

2

Please refer to Section 2.7 Page V2-T2-191.

2

Technical Data and Specifications
Frequency

Enclosures

Eaton standard dry-type
distribution transformers are
designed for 60 Hz operation.
Transformers required for
other frequencies are
available and must be
specifically designed.

Eaton encapsulated
transformers, Types EP and
EPT, use a NEMA 3R rated
enclosure as standard. NEMA
4X enclosures (grade 304 or
316 stainless steel) are
available as an option.

Overload Capability

Winding Terminations

Short-term overload is
designed into transformers as
required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250 for
additional limitations.

Primary and secondary
windings are terminated in
the wiring compartment.
Encapsulated units have
copper leads or stabs
brought out for connections.
Ventilated transformers
have leads brought out to
aluminum pads that are predrilled to accept Cu/Al lugs.
Lugs are not supplied with
these transformers. Eaton
recommends that external
cables be rated 90°C
(sized at 75°C ampacity) for
encapsulated designs and
75°C for ventilated designs.

Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.

Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:
Insulation System
Classification

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

40°C

80°C

30°C

150°C

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

40°C

150°C

30°C

220°C

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.

2

Sound Levels
All Eaton 600 volt class
general-purpose dry-type
distribution transformers are
designed to meet NEMA
ST-20 sound levels listed
here. These are the sound
levels measured in a
soundproof environment.
Actual sound levels
measured at an installation
will likely be higher due to

electrical connections and
environmental conditions.
Lower sound levels are
available and should be
specified when the
transformer is going to be
installed in an area where
sound may be a concern.
For additional information,
please refer to Section 2.7
Page V2-T2-195.

2
2
2
2
2
2

Average Sound Levels
NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
K-Factor 1, 4, 9
K-Factor 13, 20
kVA Range

Encapsulated
(up to 1.2 kV)

3.00 and below

45

40

2

40

2
2
2

3.01 to 9.00

40

40

45

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

Series-Multiple Windings

50.01 to 75.00

50

53

55

Series-multiple windings
consist of two similar coils
in each winding that can be
connected in series or parallel
(multiple). Transformers with
series-multiple windings are
designated with an “x” or
“/” between the voltage
ratings, such as voltages of
“120/240” or “240 x 480.”
If the series-multiple winding
is designated by an “x,” the
winding can be connected
only for a series or parallel.
With the “/” designation,
a mid-point also becomes
available in addition to the
series or parallel connection.
As an example, a 120 x 240
winding can be connected
for either 120 (parallel) or
240 (series), but a 120/240
winding can be connected for
120 (parallel), 240 (series) or
240 with a 120 mid-point.

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

500.01 to 700.00

62

65

61

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

2
2
2
2
2
2

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including
stainless steel), refer to Eaton.

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-109

2.5

Transformers
Distribution Transformers

Contents

2

Description

2

Distribution Transformers
Motor Drive Isolation Transformers . . . . . . . . .
Mini–Power Centers . . . . . . . . . . . . . . . . . . . .
Totally Enclosed Non-Ventilated Transformers .
Class I, Division 2, Hazardous Location
Transformers . . . . . . . . . . . . . . . . . . . . . . . . .
Open-Type Core and Coil Assembly
Transformers . . . . . . . . . . . . . . . . . . . . . . . . .
Marine Duty Transformers . . . . . . . . . . . . . . . .
Buck-Boost and Low Voltage Lighting
Transformers . . . . . . . . . . . . . . . . . . . . . . . . .
Medium Voltage Distribution Transformers . . .

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-110

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Page
V2-T2-111
V2-T2-119
V2-T2-124
V2-T2-127
V2-T2-130
V2-T2-133
V2-T2-144
V2-T2-173

Transformers
Distribution Transformers

2.5

Contents

Type MD

Description

Page

Motor Drive Isolation Transformers
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications. . . . . . . . . . .
Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . .
Totally Enclosed Non-Ventilated Transformers. . . .
Class I, Division 2, Hazardous Location Transformers
Open-Type Core and Coil Assembly Transformers
Marine Duty Transformers. . . . . . . . . . . . . . . . . . .
Buck-Boost and Low Voltage Lighting Transformers
Medium Voltage Distribution Transformers . . . . . .

V2-T2-112
V2-T2-112
V2-T2-118
V2-T2-118
V2-T2-119
V2-T2-124
V2-T2-127
V2-T2-130
V2-T2-133
V2-T2-144
V2-T2-173

2
2
2
2
2
2
2
2
2
2
2

Motor Drive Isolation Transformers
Product Description
Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.
●

●
●
●

●

Suitable for indoor or
outdoor applications
(with weathershield)
Ventilated enclosures
220°C insulation system
150°C rise standard (self
extinguishing), 115°C or
80°C rise optional
Available in ratings from 7.5
through 1500 kVA

Application Description

Features, Benefits and Functions

Drive isolation transformers
are specifically designed
for use with AC and DC
adjustable speed drives.
Two winding drive isolation
transformers provide:

●

●

●

●

●

Electrical isolation
between the incoming
line and the drive circuitry
Voltage conversion of
input line to standard
drive input voltages
Minimized line
disturbances caused by
SCR (silicon controlled
rectifiers) firing
Reduced short-circuit
currents and voltage
line transients

Drive isolation transformers
are specifically sized to the
drive kVA requirements and
are braced to withstand the
mechanical stresses of
current reversals and short
circuits associated with
SCR drives.

●

●

●

●

●

●

●

60 Hz operation (50/60 Hz
operation available)
Short-term overload
capability as required
by ANSI
Primary and secondary
terminals are front
accessible for fast
and easy connection
Slotted screw mounting
holes in enclosure
and cover reduce
installation time
Sound dampening pads,
which isolate the core
and coil from the case,
reduce noise levels to
meet NEMA ST-20
Core laminations of
precision sheared silicon
steel are hand stacked to
ensure quiet operation
Terminations are
clearly marked for
easy identification
Three-phase transformers
have one 5% full capacity
tap above and below
nominal voltage for
incoming source
adjustment

●

●
●

●

Units are suitable for
continuous operation in a
40°C ambient maximum
Full current neutral
Thermoguard protection
embedded in coils of threephase models to indicate
that high temperatures
(approximately 190°C) are
present. Thermoguards
consist of a set of NO
dry contacts
Three coil delta-wye
configurations are used
throughout the product line

Standards and Certifications
●
●
●
●

ANSI C89.2
NEMA ST-20
UL 506
UL 1561

2
2
2
2
2
2
2
2
2
2
2
2
2

Seismic Qualified
All Eaton manufactured drytype distribution transformers
are seismically qualified and
exceed requirements of the
International Building Code
(IBC) and California Code
Title 24.

2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-111

2.5
2
2

Transformers
Distribution Transformers

Catalog Number Selection
Please refer to Section 2.7 Page V2-T2-187.

Product Selection

2

Additional Product Selection information begins on Page V2-T2-189.

2

Three-Phase Drive Isolation

2

208 Delta Volts to 460Y/266 Volts

2

hp

kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

5

7.5

1 at +5%

1 at –5%

150

912D

347B

158 (72)

WS38

MD075E86

7.5

11

1 at +5%

1 at –5%

150

912D

347B

176 (80)

WS38

MD11E86

2

10

14

1 at +5%

1 at –5%

150

912D

347B

149 (68)

WS38

MD14E86

2

15

20

1 at +5%

1 at –5%

150

912D

347B

240 (19)

WS38

MD20E86

20

27

1 at +5%

1 at –5%

150

912D

347B

231 (15)

WS38

MD27E86

2

25

34

1 at +5%

1 at –5%

150

912D

347B

310 (141)

WS38

MD34E86

30

40

1 at +5%

1 at –5%

150

912D

347B

307 (139)

WS38

MD40E86

2

40

51

1 at +5%

1 at –5%

150

914F

347B

480 (218)

WS39

MD51E86

2

50

63

1 at +5%

1 at –5%

150

914F

347B

485 (220)

WS39

MD63E86

60

75

1 at +5%

1 at –5%

150

914F

347B

482 (219)

WS39

MD75E86

2

75

93

1 at +5%

1 at –5%

150

915F

347B

600 (272)

WS39

MD93E86

100

118

1 at +5%

1 at –5%

150

916A

347B

658 (299)

WS19

MD118E86

2

125

145

1 at +5%

1 at –5%

150

916A

347B

770 (350)

WS19

MD145E86

150

175

1 at +5%

1 at –5%

150

918A

321B

1320 (599)

WS34

MD175E86

2

200

220

1 at +5%

1 at –5%

150

918A

321B

1436 (652)

WS34

MD220E86

2

250

275

1 at +5%

1 at –5%

150

918A

321B

1

WS34

MD275E86

300

330

1 at +5%

1 at –5%

150

919E

321B

1

WS35

MD330E86

400

440

1 at +5%

1 at –5%

150

920E

321B

1

WS35

MD440E86

2

2
2

Full Capacity Taps

Notes
1 Contact Eaton.
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-112

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Three-Phase Drive Isolation

2
2

230 Delta Volts to 230Y/133 Volts
Full Capacity Taps
hp

kVA

FCAN

FCBN

ºC
Temp.
Rise

Frame

Wiring
Diagram
Number

Weight
Lbs (kg)

Weathershield

5

7.5

1 at +5%

1 at –5%

150

912D

286A

158 (72)

WS38

MD075E88

7.5

11

1 at +5%

1 at –5%

150

912D

286A

156 (71)

WS38

MD11E88

10

14

1 at +5%

1 at –5%

150

912D

286A

158 (72)

WS38

MD14E88

15

20

1 at +5%

1 at –5%

150

912D

286A

216 (98)

WS38

MD20E88

20

27

1 at +5%

1 at –5%

150

912D

286A

231 (105)

WS38

MD27E88

25

34

1 at +5%

1 at –5%

150

912D

286A

310 (141)

WS38

MD34E88

30

40

1 at +5%

1 at –5%

150

912D

286A

310 (141)

WS38

MD40E88

40

51

1 at +5%

1 at –5%

150

914F

286A

480 (218)

WS39

MD51E88

50

63

1 at +5%

1 at –5%

150

914F

286A

500 (227)

WS39

MD63E88

60

75

1 at +5%

1 at –5%

150

914F

286A

538 (244)

WS39

MD75E88

75

93

1 at +5%

1 at –5%

150

915F

286A

600 (272)

WS39

MD93E88

100

118

1 at +5%

1 at –5%

150

915F

286A

600 (272)

WS39

MD118E88

125

145

1 at +5%

1 at –5%

150

916A

286A

868 (394)

WS19

MD145E88

150

175

1 at +5%

1 at –5%

150

918A

318D

1320 (599)

WS34

MD175E88

200

220

1 at +5%

1 at –5%

150

918A

318D

1332 (605)

WS34

MD220E88

250

275

1 at +5%

1 at –5%

150

918A

318D

1350 (613)

WS34

MD275E88

300

330

1 at +5%

1 at –5%

150

919E

318D

2336 (1061)

WS35

MD330E88

400

440

1 at +5%

1 at –5%

150

920E

318D

1

WS35

MD440E88

Catalog Number

2
2
2
2
2
2
2
2
2
2
2
2

230 Delta Volts to 460Y/266 Volts
Full Capacity Taps

2

2

hp

kVA

FCAN

FCBN

ºC
Temp.
Rise

Frame

Wiring
Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

5

7.5

1 at +5%

1 at –5%

150

912D

347A

158 (72)

WS38

MD075E89

7.5

11

1 at +5%

1 at –5%

150

912D

347A

158 (72)

WS38

MD11E89

10

14

1 at +5%

1 at –5%

150

912D

347A

158 (72)

WS38

MD14E89

15

20

1 at +5%

1 at –5%

150

912D

347A

254 (115)

WS38

MD20E89

20

27

1 at +5%

1 at –5%

150

912D

347A

231 (105)

WS38

MD27E89

25

34

1 at +5%

1 at –5%

150

912D

347A

310 (141)

WS38

MD34E89

30

40

1 at +5%

1 at –5%

150

912D

347A

344 (156)

WS38

MD40E89

40

51

1 at +5%

1 at –5%

150

914F

347A

480 (218)

WS39

MD51E89

50

63

1 at +5%

1 at –5%

150

914F

347A

457 (207)

WS39

MD63E89

60

75

1 at +5%

1 at –5%

150

914F

347A

480 (218)

WS39

MD75E89

75

93

1 at +5%

1 at –5%

150

915F

347A

600 (272)

WS39

MD93E89

100

118

1 at +5%

1 at –5%

150

916A

347A

941 (427)

WS19

MD118E89

125

145

1 at +5%

1 at –5%

150

916A

347A

770 (350)

WS19

MD145E89

150

175

1 at +5%

1 at –5%

150

917

321A

1326 (602)

WS34

MD175E89

200

220

1 at +5%

1 at –5%

150

918A

321A

1332 (605)

WS34

MD220E89

250

275

1 at +5%

1 at –5%

150

918A

321A

1350 (613)

WS34

MD275E89

300

330

1 at +5%

1 at –5%

150

919E

321A

2400 (1090)

WS35

MD330E89

400

440

1 at +5%

1 at –5%

150

920E

321A

1

WS35

MD440E89

2
2
2
2
2
2
2
2
2
2
2

Notes
1 Contact Eaton.

2

For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-113

2.5
2

Transformers
Distribution Transformers

Three-Phase Drive Isolation

2

460 Delta Volts to 230Y/133 Volts

2

hp

kVA

2

5
7.5

2
2

Full Capacity Taps
FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram Weight
Number
Lbs (kg)

Weathershield

7.5

1 at +5%

1 at –5%

150

912D

286D

193 (88)

WS38

MD075E91

11

1 at +5%

1 at –5%

150

912D

286D

158 (72)

WS38

MD11E91

10

14

1 at +5%

1 at –5%

150

912D

286D

158 (72)

WS38

MD14E91

15

20

1 at +5%

1 at –5%

150

912D

286D

216 (98)

WS38

MD20E91

20

27

1 at +5%

1 at –5%

150

912D

286D

231 (105)

WS38

MD27E91

2

25

34

1 at +5%

1 at –5%

150

912D

286D

340 (154)

WS38

MD34E91

30

40

1 at +5%

1 at –5%

150

912D

286D

339 (154)

WS38

MD40E91

2

40

51

1 at +5%

1 at –5%

150

914

286D

535 (243)

WS39

MD51E91

2

50

63

1 at +5%

1 at –5%

150

914F

286D

480 (218)

WS39

MD63E91

60

75

1 at +5%

1 at –5%

150

914F

286D

469 (213)

WS39

MD75E91

2

75

93

1 at +5%

1 at –5%

150

915F

286D

727 (330)

WS39

MD93E91

100

118

1 at +5%

1 at –5%

150

916A

286D

770 (350)

WS19

MD118E91

2

125

145

1 at +5%

1 at –5%

150

916A

286D

770 (350)

WS19

MD145E91

150

175

1 at +5%

1 at –5%

150

917

286D

1100 (499)

WS34

MD175E91

2

200

220

1 at +5%

1 at –5%

150

917

286D

1299 (590)

WS34

MD220E91

2

250

275

1 at +5%

1 at –5%

150

918A

286D

1596 (725)

WS34

MD275E91

300

330

1 at +5%

1 at –5%

150

919E

318E

2234 (1014)

WS35

MD330E91

400

440

1 at +5%

1 at –5%

150

919E

318E

2400 (1090)

WS35

MD440E91

2

Catalog Number

2

460 Delta Volts to 400Y/231 Volts

2

hp

kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram Weight
Number
Lbs (kg)

Weathershield

Catalog Number

2

5

7.5

1 at +5%

1 at –5%

150

912D

286D

193 (88)

WS38

MD075E75

2

7.5

11

1 at +5%

1 at –5%

150

912D

286D

158 (72)

WS38

MD11E75

10

14

1 at +5%

1 at –5%

150

912D

286D

158 (72)

WS38

MD14E75

2

15

20

1 at +5%

1 at –5%

150

912D

286D

216 (98)

WS38

MD20E75

20

27

1 at +5%

1 at –5%

150

912D

286D

231 (105)

WS38

MD27E75

2

25

34

1 at +5%

1 at –5%

150

912D

286D

340 (154)

WS38

MD34E75

30

40

1 at +5%

1 at –5%

150

912D

286D

339 (154)

WS38

MD40E75

2

40

51

1 at +5%

1 at –5%

150

914F

286D

535 (243)

WS39

MD51E75

2

50

63

1 at +5%

1 at –5%

150

914F

286D

480 (218)

WS39

MD63E75

60

75

1 at +5%

1 at –5%

150

914F

286D

469 (213)

WS39

MD75E75

2

75

93

1 at +5%

1 at –5%

150

915F

286D

727 (330)

WS39

MD93E75

100

118

1 at +5%

1 at –5%

150

916A

286D

770 (350)

WS19

MD118E75

2

125

145

1 at +5%

1 at –5%

150

916A

286D

770 (350)

WS19

MD145E75

150

175

1 at +5%

1 at –5%

150

917

286D

1100 (499)

WS34

MD175E75

2

200

220

1 at +5%

1 at –5%

150

917

286D

1299 (590)

WS34

MD220E75

2

250

275

1 at +5%

1 at –5%

150

918A

286D

1596 (725)

WS34

MD275E75

300

330

1 at +5%

1 at –5%

150

919E

318E

2234 (1014)

WS35

MD330E75

400

440

1 at +5%

1 at –5%

150

919E

318E

2400 (1090)

WS35

MD440E75

2
2

Full Capacity Taps

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
V2-T2-114

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Three-Phase Drive Isolation

2
2

460 Delta Volts to 460Y/266 Volts
Full Capacity Taps
FCAN

FCBN

ºC Temp.
Rise

7.5

1 at +5%

1 at –5%

150

912D

286D

164 (74)

WS38

MD075E92

11

1 at +5%

1 at –5%

150

912D

286D

161 (73)

WS38

MD11E92

10

14

1 at +5%

1 at –5%

150

912D

286D

173 (79)

WS38

MD14E92

15

20

1 at +5%

1 at –5%

150

912D

286D

231 (105)

WS38

MD20E92

20

27

1 at +5%

1 at –5%

150

912D

286D

250 (114)

WS38

MD27E92

25

34

1 at +5%

1 at –5%

150

912D

286D

310 (141)

WS38

MD34E92

30

40

1 at +5%

1 at –5%

150

912D

286D

310 (141)

WS38

MD40E92

40

51

1 at +5%

1 at –5%

150

914F

286D

503 (228)

WS39

MD51E92

50

63

1 at +5%

1 at –5%

150

914F

286D

535 (243)

WS39

MD63E92

60

75

1 at +5%

1 at –5%

150

914F

286D

535 (243)

WS39

MD75E92

75

93

1 at +5%

1 at –5%

150

916A

286D

710 (322)

WS19

MD93E92

100

118

1 at +5%

1 at –5%

150

916A

286D

770 (350)

WS19

MD118E92

125

145

1 at +5%

1 at –5%

150

916A

286D

866 (393)

WS19

MD145E92

150

175

1 at +5%

1 at –5%

150

917

286D

1100 (499)

WS34

MD175E92

200

220

1 at +5%

1 at –5%

150

917

286D

1100 (499)

WS34

MD220E92

250

275

1 at +5%

1 at –5%

150

918A

286D

1469 (667)

WS34

MD275E92

300

330

1 at +5%

1 at –5%

150

919E

318E

2587 (1174)

WS35

MD330E92

400

440

1 at +5%

1 at –5%

150

919E

318E

2500 (1135)

WS35

MD440E92

hp

kVA

5
7.5

Frame

Wiring Diagram Weight
Number
Lbs (kg)

Weathershield

Catalog Number

2
2
2
2
2
2
2
2
2
2
2

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-115

2.5
2

Transformers
Distribution Transformers

Three-Phase Drive Isolation

2

480 Delta Volts to 240 Delta Volts

2

hp

kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram Weight
Number
Lbs (kg)

Weathershield

5

7.5

1 at +5%

1 at –5%

150

912D

300A

193 (88)

WS38

MD075E77

7.5

11

1 at +5%

1 at –5%

150

912D

300A

158 (72)

WS38

MD11E77

2

10

14

1 at +5%

1 at –5%

150

912D

300A

158 (72)

WS38

MD14E77

2

15

20

1 at +5%

1 at –5%

150

912D

300A

185 (84)

WS38

MD20E77

20

27

1 at +5%

1 at –5%

150

912D

300A

231 (105)

WS38

MD27E77

2

25

34

1 at +5%

1 at –5%

150

912D

300A

329 (149)

WS38

MD34E77

30

40

1 at +5%

1 at –5%

150

912D

300A

339 (154)

WS38

MD40E77

2

40

51

1 at +5%

1 at –5%

150

914F

300A

535 (243)

WS39

MD51E77

2

50

63

1 at +5%

1 at –5%

150

914F

300A

480 (218)

WS39

MD63E77

60

75

1 at +5%

1 at –5%

150

914F

300A

469 (213)

WS39

MD75E77

2

75

93

1 at +5%

1 at –5%

150

915F

300A

727 (330)

WS39

MD93E77

100

118

1 at +5%

1 at –5%

150

916A

300A

770 (350)

WS19

MD118E77

2

125

145

1 at +5%

1 at –5%

150

916A

300A

770 (350)

WS19

MD145E77

150

175

1 at +5%

1 at –5%

150

917

300A

1100 (499)

WS34

MD175E77

2

200

220

1 at +5%

1 at –5%

150

917

300A

1299 (590)

WS34

MD220E77

2

250

275

1 at +5%

1 at –5%

150

918A

300A

1596 (725)

WS34

MD275E77

300

330

1 at +5%

1 at –5%

150

919E

348D

2234 (1014)

WS35

MD330E77

400

440

1 at +5%

1 at –5%

150

919E

348D

2400 (1090)

WS35

MD440E77

2

2

Full Capacity Taps

Catalog Number

2

480 Delta Volts to 480 Delta Volts

2

hp

kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram Weight
Number
Lbs (kg)

Weathershield

Catalog Number

2

5

7.5

1 at +5%

1 at –5%

150

912D

300A

193 (88)

WS38

MD075E99

2

7.5

11

1 at +5%

1 at –5%

150

912D

300A

158 (72)

WS38

MD11E99

10

14

1 at +5%

1 at –5%

150

912D

300A

158 (72)

WS38

MD14E99

2

15

20

1 at +5%

1 at –5%

150

912D

300A

185 (84)

WS38

MD20E99

20

27

1 at +5%

1 at –5%

150

912D

300A

231 (105)

WS38

MD27E99

2

25

34

1 at +5%

1 at –5%

150

912D

300A

329 (149)

WS38

MD34E99

30

40

1 at +5%

1 at –5%

150

912D

300A

339 (154)

WS38

MD40E99

2

40

51

1 at +5%

1 at –5%

150

914F

300A

535 (243)

WS39

MD51E99

2

50

63

1 at +5%

1 at –5%

150

914F

300A

480 (218)

WS39

MD63E99

60

75

1 at +5%

1 at –5%

150

914F

300A

469 (213)

WS39

MD75E99

75

93

1 at +5%

1 at –5%

150

915F

300A

727 (330)

WS39

MD93E99

100

118

1 at +5%

1 at –5%

150

916A

300A

770 (350)

WS19

MD118E99

2
2

Full Capacity Taps

125

145

1 at +5%

1 at –5%

150

916A

300A

770 (350)

WS19

MD145E99

150

175

1 at +5%

1 at –5%

150

917

300A

1100 (499)

WS34

MD175E99

2

200

220

1 at +5%

1 at –5%

150

917

300A

1299 (590)

WS34

MD220E99

2

250

275

1 at +5%

1 at –5%

150

918A

300A

1596 (725)

WS34

MD275E99

300

330

1 at +5%

1 at –5%

150

919E

348D

2234 (1014)

WS35

MD330E99

400

440

1 at +5%

1 at –5%

150

919E

348D

2400 (1090)

WS35

MD440E99

2
2

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
V2-T2-116

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Three-Phase Drive Isolation

2
2

575 Delta Volts to 460Y/266 Volts
Full Capacity Taps
hp

kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram Weight
Number
Lbs (kg)

Weathershield

Catalog Number

5

7.5

1 at +5%

1 at –5%

150

912D

286H

158 (72)

WS38

MD075E95

7.5

11

1 at +5%

1 at –5%

150

912D

286H

158 (72)

WS38

MD11E95

10

14

1 at +5%

1 at –5%

150

912D

286H

158 (72)

WS38

MD14E95

15

20

1 at +5%

1 at –5%

150

912D

286H

272 (123)

WS38

MD20E95

20

27

1 at +5%

1 at –5%

150

912D

286H

266 (121)

WS38

MD27E95

25

34

1 at +5%

1 at –5%

150

912D

286H

360 (163)

WS38

MD34E95

30

40

1 at +5%

1 at –5%

150

912D

286H

310 (141)

WS38

MD40E95

40

51

1 at +5%

1 at –5%

150

914F

286H

504 (229)

WS39

MD51E95

50

63

1 at +5%

1 at –5%

150

914F

286H

506 (230)

WS39

MD63E95

60

75

1 at +5%

1 at –5%

150

914F

286H

524 (238)

WS39

MD75E95

75

93

1 at +5%

1 at –5%

150

916A

286H

730 (331)

WS19

MD93E95

100

118

1 at +5%

1 at –5%

150

916A

286H

770 (350)

WS19

MD118E95

125

145

1 at +5%

1 at –5%

150

916A

286H

770 (350)

WS19

MD145E95

150

175

1 at +5%

1 at –5%

150

917

286H

1282 (582)

WS34

MD175E95

200

220

1 at +5%

1 at –5%

150

917

286H

1201 (545)

WS34

MD220E95

250

275

1 at +5%

1 at –5%

150

923

318F

702 (319)

WS37

MD275E95

300

330

1 at +5%

1 at –5%

150

919E

318F

2263 (1027)

WS35

MD330E95

400

440

1 at +5%

1 at –5%

150

919E

318F

2400 (1090)

WS35

MD440E95

2
2
2
2

Weathershield

912D

286H

158 (72)

WS38

MD075E96

912D

286H

158 (72)

WS38

MD11E96

912D

286H

231 (105)

WS38

MD14E96

912D

286H

231 (105)

WS38

MD20E96

150

912D

286H

231 (105)

WS38

MD27E96

150

912D

286H

261 (118)

WS38

MD34E96

1 at –5%

150

912D

286H

310 (141)

WS38

MD40E96

1 at +5%

1 at –5%

150

914F

286H

480 (218)

WS39

MD51E96

1 at +5%

1 at –5%

150

914F

286H

500 (227)

WS39

MD63E96

75

1 at +5%

1 at –5%

150

914F

286H

538 (244)

WS39

MD75E96

93

1 at +5%

1 at –5%

150

916A

286H

600 (272)

WS19

MD93E96

118

1 at +5%

1 at –5%

150

916A

286H

948 (430)

WS19

MD118E96

FCBN

2
2
2
2
2
2

Wiring Diagram Weight
Number
Lbs (kg)

FCAN

2
2

575 Delta Volts to 575Y/332 Volts
Full Capacity Taps

2

ºC Temp.
Rise

hp

kVA

5

7.5

1 at +5%

1 at –5%

150

7.5

11

1 at +5%

1 at –5%

150

10

14

1 at +5%

1 at –5%

150

15

20

1 at +5%

1 at –5%

150

20

27

1 at +5%

1 at –5%

25

34

1 at +5%

1 at –5%

30

40

1 at +5%

40

51

50

63

60
75
100

Frame

Catalog Number

125

145

1 at +5%

1 at –5%

150

916A

286H

868 (394)

WS19

MD145E96

150

175

1 at +5%

1 at –5%

150

917

286H

1320 (599)

WS34

MD175E96

200

220

1 at +5%

1 at –5%

150

917

286H

1332 (605)

WS34

MD220E96

250

275

1 at +5%

1 at –5%

150

918A

318F

1350 (613)

WS34

MD275E96

300

330

1 at +5%

1 at –5%

150

919E

318F

2336 (1061)

WS35

MD330E96

400

440

1 at +5%

1 at –5%

150

919E

318F

2500 (1137)

WS35

MD440E96

2
2
2
2
2
2
2
2
2
2
2

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-117

2.5
2

Accessories

2

●

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

●

●
●
●
●

Transformers
Distribution Transformers

Copper windings
Non-standard voltages
50/60 Hz designs
Delta-delta configuration
80°C or 115°C rise designs
Encapsulated designs (up
to 34 kVA). Thermoguards
are not available on
encapsulated designs

●

●

Totally enclosed
non-ventilated
Electrostatic shields

Please refer to Section 2.7
Page V2-T2-191.

Technical Data and Specifications
Frequency
Eaton standard dry-type
distribution transformers are
designed for 60 Hz operation.
Transformers required for
other frequencies are
available and must be
specifically designed.
Overload Capability
Short-term overload is
designed into transformers
as required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250 for
additional limitations.
Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.

Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:
Insulation System
Classification

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

40°C

80°C

30°C

150°C

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

40°C

150°C

30°C

220°C

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.

Enclosures
Eaton ventilated transformers,
Type MD, use a NEMA 2
rated (drip-proof) enclosure
as standard, and are rated
NEMA 3R with the addition
of weathershields.

Sound Levels
All Eaton 600 volt class
general-purpose dry-type
distribution transformers are
designed to meet NEMA
ST-20 sound levels listed
here. These are the sound
levels measured in a
soundproof environment.
Actual sound levels
measured at an installation
will likely be higher due to
electrical connections and
environmental conditions.
Lower sound levels are
available and should be
specified when the
transformer is going to be
installed in an area where
sound may be a concern.

Winding Terminations
Primary and secondary
windings are terminated in
the wiring compartment.
Ventilated transformers
have leads brought out to
aluminum pads that are predrilled to accept Cu/Al lugs.
Lugs are not supplied with
these transformers. Eaton
recommends that external
cables be rated 75°C for
ventilated designs.

For additional information,
please refer to Section 2.7
Page V2-T2-195.

Average Sound Levels
NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

Encapsulated
(up to 1.2 kV)

3.00 and below

40

40

45

2

3.01 to 9.00

40

40

45

2

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

2

30.01 to 50.00

45

48

50

50.01 to 75.00

50

53

55

2

75.01 to 112.50

50

53

55

2

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

2

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

2

500.01 to 700.00

62

65

61

700.01 to 1000.00

64

67

63

2

Greater than 1000

Consult factory

Consult factory

Consult factory

2

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including
stainless steel), refer to Eaton.

2
V2-T2-118

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Contents
Description

Page

Motor Drive Isolation Transformers . . . . . . . . . . . .
Mini–Power Centers
Standards and Certifications. . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications. . . . . . . . . . .
Totally Enclosed Non-Ventilated Transformers. . . .
Class I, Division 2, Hazardous Location Transformers
Open-Type Core and Coil Assembly Transformers
Marine Duty Transformers. . . . . . . . . . . . . . . . . . .
Buck-Boost and Low Voltage Lighting Transformers
Medium Voltage Distribution Transformers . . . . . .

V2-T2-111
V2-T2-120
V2-T2-121
V2-T2-121
V2-T2-123
V2-T2-123
V2-T2-124
V2-T2-127
V2-T2-130
V2-T2-133
V2-T2-144
V2-T2-173

2
2
2
2
2
2
2
2
2
2
2

Mini–Power Centers
Product Description
Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.
●
●

●
●

Encapsulated design
Suitable for indoor or
outdoor applications
180°C insulation system
115°C rise standard;
80°C rise optional

Application Description

Features, Benefits and Functions

A mini–power center
combines three individual
components into one NEMA
Type 3R enclosure: a main
breaker, an encapsulated
single-phase (Type EP) or
three-phase (EPT) dry-type
transformer, and a secondary
distribution loadcenter with
main breaker. Interconnecting
wiring is completed at the
factory. Mini–power centers
are used wherever there
is a 480 volt or 600 volt
distribution system and
loads requiring 208Y/120 volt,
three-phase or 120/240 volt
single-phase. Typical
installations include:

●

Industrial plant
assembly lines
Plant expansions
Test equipment
Temporary construction
site power
Sewage disposal plants
Warehouses
Car washes
Parking lots
Commercial buildings

●

●

●
●
●

●
●
●
●
●

●
●
●

●

●

●

●

●

60 Hz operation
Indoor/outdoor, NEMA 3R
Primary main breaker
Secondary main breaker
(Type BR plug-in and Type
BAB bolt-on feeder
breakers not included)
All live parts enclosed
for personnel safety
Cover is hinged to prevent
removal and can be
padlocked
Cores are grounded with
a copper lead
Ground bar is supplied
to permit grounding of
individual secondary
circuits
Neutral bar is grounded
to case
Feeder circuits can be
easily added or changed
using Type BR plug-in
breakers and Type BR plugin and Type BAB bolt-on

●

●

●

●

Suitable for service
entrance
Wide range of
configurations available:
● Aluminum windings
and plug-in loadcenter
chassis standard
● Copper windings and
plug-in loadcenter
chassis also available
● Copper windings and
bolt-on loadcenter
chassis available
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-119

2.5

Transformers
Distribution Transformers

2

Standards and Certifications

2

●

●

UL listed
CSA® certified

2
2
2
2
2
2
2
2
2
2

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA,
ANSI and IEEE Standards. All
600 volt class transformers
are UL listed unless
otherwise noted.
Seismically Qualified
Eaton manufactured dry-type
distribution transformers
are seismically qualified
and exceed requirements of
the International Building
Code (IBC) and California
Code Title 24.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-120

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.5

Transformers
Distribution Transformers

Catalog Number Selection
Please refer to Section 2.7 Page V2-T2-187.

2

Product Selection

2

Additional Product Selection information begins on Page V2-T2-189.

2

Single-Phase

2
2

480 Volts to 120/240 Volts
Main Circuit Breaker

Feeder Breakers Max. Number 23

Primary 1

Single-Pole

kVA

Full Capacity
Taps FCBN

Frame

Wiring
Diagram
Number

3

2 at –5%

FR283

97A3K

105 (47)

EHD2015

BR215

8

5

2 at –5%

FR284

110A5K

110 (50)

EHD2020

BR225

12

7.5

2 at –5%

FR284

109A7K

125 (56)

EHD2030

BR230

12

10

2 at –5%

FR285

108A10K

180 (82)

EHD2040

BR250

15

2 at –5%

FR286

107A15K

215 (98)

EHD2060

BR270

25

2 at –5%

FR287

106A25K

373 (169)

EHD2100

BR2125

Weight
Lbs (kg)

Secondary

2

Max.
Amp

Catalog
Number

4

12

P48G11S03P

6

20

P48G11S05P

6

30

P48G11S07P

12

6

40

P48G11S10P

20

10

60

P48G11S15P

26

13

100

P48G11S25P

Two-Pole

kVA
5

2 at –5%

Feeder Breakers Max. Number 23

Frame

Wiring
Diagram
Number

Weight
Lbs (kg)

Primary 1

Secondary

Single-Pole

FR284

110B5K

110 (50)

FDB2015

BR225

12

Main Circuit Breaker

Two-Pole

Max.
Amp

Catalog
Number

6

20

P60G11S05P

7.5

2 at –5%

FR284

109B7K

125 (56)

FDB2030

BR230

12

6

30

P60G11S07P

10

2 at –5%

FR285

108B10K

180 (82)

FDB2040

BR250

12

6

40

P60G11S10P

15

2 at –5%

FR286

107B15K

215 (98)

FDB2060

BR270

20

10

60

P60G11S15P

25

2 at –5%

FR287

106B25K

373 (169)

FDB2100

BR2125

26

13

100

P60G11S25P

kVA

2 at –5%

Feeder Breakers Max. Number 23

Frame

Wiring
Diagram
Number

Weight
Lbs (kg)

Primary

Secondary

Single-Pole

Two-Pole

FR289A

105A15K

320 (145)

EHD3040

BR350

18

9

Main Circuit Breaker

Three-Pole

Max.
Amp

Catalog
Number

6

40

P48G28T15P

22.5

2 at –5%

FR290A

103A21K

565 (256)

EHD3070

BR370

18

9

6

60

P48G28T21P

30

2 at –5%

FR291A

104A30K

635 (288)

EHD3090

BR3100

24

12

8

80

P48G28T30P

Full Capacity
Taps FCBN

2
2
2
2
2

Frame

2
2
2
2
2

600 Delta Volts to 208Y/120 Volts

kVA

2

2

480 Delta Volts to 208Y/120 Volts

15

2

2

Three-Phase

Full Capacity
Taps FCBN

2

2

600 Volts to 120/240 Volts
Full Capacity
Taps FCBN

2

Wiring
Diagram
Number

Weight
Lbs (kg)

Main Circuit Breaker

Feeder Breakers Max. Number 23

Primary

Single-Pole

Secondary

Two-Pole

Three-Pole

Max.
Amp

Catalog
Number

15

2 at –5%

FR289A

105D15K

320 (145)

FDB3030

BR350

18

9

6

40

P60G28T15P

22.5

2 at –5%

FR290A

103B21K

565 (256)

FDB3050

BR370

18

9

6

60

P60G28T21P

30

2 at –5%

FR291A

104B30K

635 (288)

FDB3070

BR3100

24

12

8

80

P60G28T30P

2
2
2

Notes
1 Primary breakers with higher interrupting capacity available. For HFD breaker, add suffix “H.” For FD breaker, add suffix “F.” For FDC breaker, add suffix “C.”
Main breakers are fixed only.
2 Combinations can be selected.
3 Feeder breakers not included. Use Eaton’s Type BR.

2

For 304 grade stainless steel enclosure, replace 10th character of catalog number with an “SS” suffix, e.g., P48G11S03SS, or add “SS” suffix before the addition of “CUB.”
For 316 grade stainless steel enclosure, replace 10th character of catalog number with an “S6” suffix, e.g., P48G11S03S6, or add “S6” suffix before the addition of “CUB.”
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2

V2-T2-121

2
2

2.5
2
2
2

480 Volts to 120/240 Volts
Main Circuit Breaker

Feeder Breakers Max. Number 23

Frame

Wiring
Diagram
Number

Weight
Lbs (kg)

Primary 1

Secondary

Single-Pole

Two-Pole

Max.
Amp

Catalog
Number

2 at –5%

FR306

97A3K

105 (47)

EHD2015L

BAB2015

8

4

12

P48G11S03CUB

2 at –5%

FR307

110A5K

110 (50)

EHD2020L

BAB2025

12

6

20

P48G11S05CUB

7.5

2 at –5%

FR307

109A7K

110 (50)

EHD2030L

BAB2030

12

6

30

P48G11S07CUB

10

2 at –5%

FR308

108A10K

180 (82)

EHD2040L

BAB2050

12

6

40

P48G11S10CUB

15

2 at –5%

FR309

108A15K

215 (98)

EHD2060L

BAB2070

24

12

60

P48G11S15CUB

25

2 at –5%

FR310

106A25K

385 (175)

EHD2100L

BAB2125

26

13

100

P48G11S25CUB

Main Circuit Breaker

Feeder Breakers Max. Number 23

Weight
Lbs (kg)

Primary 1

Secondary

Single-Pole

Two-Pole

Max.
Amp

Catalog
Number

kVA
3

2

5

2
2
2
2

Distribution Transformers

All Copper, Bolt-On Breaker Designs—Single-Phase

Full Capacity
Taps FCBN

2

Transformers

600 Volts to 120/240 Volts

kVA

Full Capacity
Taps FCBN

Frame

Wiring
Diagram
Number

3

2 at –5%

FR306

97B3K

105 (47)

FDB2015L

BAB2015

8

4

12

P60G11S03CUB

5

2 at –5%

FR307

110B5K

110 (50)

FDB2020L

BAB2025

12

6

20

P60G11S05CUB

2

7.5

2 at –5%

FR307

109B7K

110 (50)

FDB2030L

BAB2030

12

6

30

P60G11S07CUB

10

2 at –5%

FR308

108B10K

180 (82)

FDB2040L

BAB2050

12

6

40

P60G11S10CUB

2

15

2 at –5%

FR309

108B15K

215 (98)

FDB2060L

BAB2070

24

12

60

P60G11S15CUB

25

2 at –5%

FR310

106B25K

385 (175)

FDB2100L

BAB2125

26

13

100

P60G11S25CUB

Main Circuit Breaker

Feeder Breakers Max. Number 23

Weight
Lbs (kg)

Primary

Secondary

Single-Pole

Two-Pole

Three-Pole

Max.
Amp

2
2

2
2
2
2
2
2

Three-Phase

480 Volts to 208Y/120 Volts

kVA

Full Capacity
Taps FCBN

Frame

Wiring
Diagram
Number

Catalog
Number

15

2 at –5%

FR289A

105A15K

320 (145)

EHD3040L

BAB3050H

18

9

6

40

P48G28T15CUB

22.5

2 at –5%

FR290A

103A21K

565 (257)

EHD3070L

BAB3070H

18

9

6

60

P48G28T21CUB

30

2 at –5%

FR291A

104A30K

635 (288)

EHD3090L

BAB3100H

24

12

8

80

P48G28T30CUB

Main Circuit Breaker

Feeder Breakers Max. Number 23

Weight
Lbs (kg)

Primary

Secondary

Single-Pole

Two-Pole

Three-Pole

Max.
Amp

Catalog
Number

2
2

600 Volts to 208Y/120 Volts

kVA

Full Capacity
Taps FCBN

Frame

Wiring
Diagram
Number

2

15

2 at –5%

FR289A

105D15K

320 (145)

FDB3030L

BAB3050H

18

9

6

40

P60G28T15CUB

22.5

2 at –5%

FR290A

103B21K

565 (257)

FDB3050L

BAB3070H

18

9

6

60

P60G28T21CUB

2

30

2 at –5%

FR291A

104B30K

635 (288)

FDB3070L

BAB3100H

24

12

8

80

P60G28T30CUB

2

2

Notes
1 Primary breakers with higher interrupting capacity available. For HFD breaker, add suffix “H.” For FD breaker, add suffix “F.” For FDC breaker, add suffix “C.”
Main breakers are fixed only. UL Listed only, not CSA.
2 Combinations can be selected.
3 Feeder breakers not included. Use Eaton’s Type BAB.

2

For 304 grade stainless steel enclosure, replace 10th character of catalog number with an “SS” suffix, e.g., P48G11S03SS, or add “SS” suffix before the addition of “CUB.”
For 316 grade stainless steel enclosure, replace 10th character of catalog number with an “S6” suffix, e.g., P48G11S03S6, or add “S6” suffix before the addition of “CUB.”
For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2

2
2
2
V2-T2-122

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.5

Transformers
Distribution Transformers

Accessories

2

Please refer to Section 2.7
Page V2-T2-191.

2

Technical Data and Specifications
Frequency
Eaton standard dry-type
distribution transformers are
designed for 60 Hz operation.
Transformers required for
other frequencies must be
specifically designed.
Overload Capability
Short-term overload is
designed into transformers as
required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250 for
additional limitations.
Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.

2

Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:
Insulation System
Classification

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

40°C

80°C

30°C

150°C

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

40°C

150°C

30°C

220°C

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.
Winding Terminations
Eaton recommends that
external cables be rated 90°C
(sized at 75°C ampacity) for
encapsulated designs and
75°C for ventilated designs.

Sound Levels
All Eaton 600 volt class
general-purpose dry-type
distribution transformers are
designed to meet NEMA
ST-20 sound levels listed
here. These are the sound
levels measured in a
soundproof environment.
Actual sound levels
measured at an installation

will likely be higher due to
electrical connections and
environmental conditions.
Lower sound levels are
available and should be
specified when the
transformer is going to be
installed in an area where
sound may be a concern.

2
2
2
2
2
2

Average Sound Levels

2

NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

Encapsulated
(up to 1.2 kV)

2

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

2
2

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

50.01 to 75.00

50

53

55

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

500.01 to 700.00

62

65

61

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

2
2
2
2
2

Note
For other ratings or catalog numbers not shown, or for special enclosure types (including
stainless steel), refer to Eaton. The following pages provide listings for most standard
transformer ratings and styles. For all-copper and bolt-on-breaker designs, contact Eaton.

2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-123

2.5
2

Transformers
Distribution Transformers

Three-Phase Type DT-3E Totally Enclosed Non-Ventilated

Contents
Description

2

Page

Motor Drive Isolation Transformers. . . . . . . . . . . .
Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . .
Totally Enclosed Non-Ventilated Transformers
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection. . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Class I, Division 2, Hazardous Location Transformers
Open-Type Core and Coil Assembly Transformers
Marine Duty Transformers . . . . . . . . . . . . . . . . . .
Buck-Boost and Low Voltage Lighting Transformers
Medium Voltage Distribution Transformers. . . . . .

2
2
2
2
2
2

V2-T2-111
V2-T2-119
V2-T2-125
V2-T2-125
V2-T2-126
V2-T2-126
V2-T2-127
V2-T2-130
V2-T2-133
V2-T2-144
V2-T2-173

2
2
2

Totally Enclosed Non-Ventilated Transformers

2

Product Description

2
2
2
2
2

Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.
●

●

2
2
2

●
●

Suitable for indoor or
outdoor applications
Totally enclosed, nonventilated enclosures
rated NEMA 3R
220°C insulation system
150°C rise standard;
115°C or 80°C rise optional

2
2
2
2
2
2
2

Application Description
Totally enclosed nonventilated dry-type
transformers are for special
applications, where because
of adverse atmospheric
conditions it is desirable to
use a dry-type non-ventilated
transformer vs. the ventilated
standard unit, which has
openings in its enclosure
to allow air to flow directly
over the core and coil.

Features, Benefits
and Functions
●

●

●

60 Hz operation (50/60 Hz
operation available)
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels

In applications where the
atmosphere contains
conductive, corrosive, or
combustible materials, which
might damage a transformer,
or lint and dust flyings that
might block the ventilation
passages, the non-ventilated
transformer is highly suited.
It has no openings in the
enclosure. Heat is dissipated
by radiating from the surface
area of the enclosure.
Consequently, the enclosures
are larger than those of the
standard ventilated type.
Non-ventilated transformers
are suited for application in
the textile, chemical,
automotive, petrochemical,
foundry, cement, food, paper
and other industries.

2
2
2
V2-T2-124

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Standards and Certifications
●

UL listed

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards.
Seismically Qualified
Eaton manufactured dry-type
distribution transformers are
seismically qualified and
exceed requirements of the
International Building Code
(IBC) and California Code
Title 24.

Transformers
Distribution Transformers

2.5

Catalog Number Selection
Please refer to Section 2.7 Page V2-T2-187.

2

Product Selection

2

Additional Product Selection information begins on Page V2-T2-189.

2

Single-Phase—Type DS-3E, 60 Hz 1

2
2

240 x 480 Volts to 120/240 Volts +1–5%, –2–5% at 240 Volts Primary; +2–2.5%, –4–2.5% at 480 Volts Primary
kVA

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Catalog
Number

2

15

DS-3E

150

FR817N

3XA

350 (159)

T20P11S15NV

25

DS-3E

150

FR818N

3XA

350 (159)

T20P11S25NV

2

37.5

DS-3E

150

FR820N

3XA

600 (274)

T20P11S37NV

50

DS-3E

150

FR820N

3XA

720 (329)

T20P11S50NV

Three-Phase—Type DT-3E, 60 Hz

2
2
2

1

2

480 Delta Volts to 208Y/120 Volts +2–2.5% FCAN, 4–2.5% FCBN Taps
Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Catalog
Number

2
2

kVA

Type

°C Temp.
Rise

15

DT-3E

150

FR914FN

280B

480 (217)

V48M28T15NV

30

DT-3E

150

FR914FN

280B

480 (217)

V48M28T30NV

45

DT-3E

150

FR915FN

280B

600 (272)

V48M28T45NV

75

DT-3E

150

FR916AN

280B

760 (344)

V48M28T75NV

112.5

DT-3E

150

FR917N

280B

1100 (499)

V48M28T12NV

150

DT-3E

150

FR918AN

280B

1300 (589)

V48M28T49NV

225

DT-3E

150

FR919EN

275A

2400 (1088)

V48M28T22NV

300

DT-3E

150

FR920EN

275A

2900 (1315)

V48M28T33NV

2
2
2

Notes
1 Transformers Type EPT 75 kVA and smaller three-phase, and Type EP 37.5 kVA and smaller single-phase, are furnished non-ventilated normally, as standard. See general-purpose transformers.
Contact your local Eaton sales office for availability of additional totally enclosed non-ventilated transformers. Contact your local Eaton sales office for CE Mark transformer requirements. For other
ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-125

2.5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Transformers
Distribution Transformers

Accessories
Please refer to Section 2.7 Page V2-T2-191.

Technical Data and Specifications
Frequency
Eaton standard dry-type
distribution transformers are
designed for 60 Hz operation.
Transformers required for
other frequencies are
available and must be
specifically designed.
Overload Capability
Short-term overload is
designed into transformers
as required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250 for
additional limitations.
Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.

Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:
Insulation System
Classification

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

40°C

80°C

30°C

150°C

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

40°C

150°C

30°C

220°C

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.

Enclosures
Eaton totally enclosed,
non-ventilated transformers,
Types DS-3E and DT-3E,
use a NEMA 3R rated
enclosure as standard.
Winding Terminations
Primary and secondary
windings are terminated
in the wiring compartment.
Totally enclosed nonventilated transformers
have leads brought out to
aluminum pads that are
pre-drilled to accept Cu/Al
lugs. Lugs are not supplied
with these transformers.
Eaton recommends external
cables be rated 75°C for
ventilated designs.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-126

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Series-Multiple Windings
Series-multiple windings
consist of two similar coils
in each winding that can be
connected in series or parallel
(multiple). Transformers with
series-multiple windings are
designated with an “x” or
“/” between the voltage
ratings, such as voltages of
“120/240” or “240 x 480.”
If the series-multiple winding
is designated by an “x,” the
winding can be connected
only for a series or parallel.
With the “/” designation,
a mid-point also becomes
available in addition to the
series or parallel connection.
As an example, a 120 x 240
winding can be connected
for either 120 (parallel) or
240 (series), but a 120/240
winding can be connected for
120 (parallel), or 240 (series),
or 240 with a 120 mid-point.
Note: The preceding pages
provide listings for most standard
transformer ratings and catalog
numbers. For all-copper and
bolt-on-breaker designs, contact
Eaton. For other ratings or catalog
numbers not shown, or for special
enclosure types (including
stainless steel), refer to Eaton.

Transformers
Distribution Transformers

2.5

Contents

Single-Phase Type EPZ Encapsulated

Description
Motor Drive Isolation Transformers . . . . . . . . . . . .
Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . .
Totally Enclosed Non-Ventilated Transformers. . . .
Class I, Division 2, Hazardous Location Transformers
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications. . . . . . . . . . .
Open-Type Core and Coil Assembly Transformers
Marine Duty Transformers. . . . . . . . . . . . . . . . . . .
Buck-Boost and Low Voltage Lighting Transformers
Medium Voltage Distribution Transformers . . . . . .

Page

2

V2-T2-111
V2-T2-119
V2-T2-124

2

V2-T2-128
V2-T2-128
V2-T2-129
V2-T2-129
V2-T2-130
V2-T2-133
V2-T2-144
V2-T2-173

2
2
2
2
2
2
2
2
2

Class I, Division 2, Hazardous Location Transformers
Product Description
Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.
●
●

●

●
●

●

●

●

Encapsulated design
Suitable for indoor or
outdoor applications
Totally enclosed, nonventilated enclosures
180°C insulation system
115°C rise standard;
80°C rise optional
Mountable in any position
indoors. Upright only
outdoors
Available in ratings up to
600 volts primary, 25 kVA
single-phase, 75 kVA
three-phase
Available in NEMA Type 4X
enclosure

Application Description
Type EPZ and EPTZ
transformers are labeled as
“Suitable for use in Class I,
Division 2, Groups A, B, C
and D locations, as defined by
NEC Article 501, with NECrecommended installation
procedures for dry-type
transformers rated under
600 volts nominal operation.”
A Class I, Division 2 location
per Section 500 of the NEC is
defined as:
6. A location in which
volatile flammable liquids
or gases are handled,
processed or used, but
that normally will be
confined within closed
containers or systems
from which they can
escape only in case of
accidental rupture or
breakdown of the
container or system.
7. Or, a location where
ignitable concentrations
of gases or vapors are
normally prevented by
positive mechanical
ventilation and that
might become hazardous
through failure of the
ventilation equipment.

Standards and Certifications
8. Or, a location that is
adjacent to a Class I,
Division 1 location and
ignitable concentrations
of gases or vapors might
occasionally enter.
Atmospheres classified by
NEC Section 500 as Group A
includes acetylene. Group B
includes gases such as
hydrogen and formaldehyde.
Group C may contain gases
or vapors such as ethyl ether,
ethylene, or the equivalent.
Atmospheres classified as
Group D may contain gases
or vapors such as acetone,
ammonia, benzene, butane,
cyclopropane, ethanol,
gasoline, hexane, methanol,
methane, natural gas,
naphtha, propane or the
equivalent.

●

UL listed

2
2

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards.
Seismically Qualified
Eaton manufactured dry-type
distribution transformers are
seismically qualified and
exceed requirements of the
International Building Code
(IBC) and California Code
Title 24.

●
●

●

●

2
2
2
2
2
2
2
2
2

Features, Benefits
and Functions
●

2

2

NEMA 3R enclosure
60 Hz operation
Aluminum windings
(copper optional)
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels

2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-127

2.5
2
2

Transformers
Distribution Transformers

Catalog Number Selection
Please refer to Section 2.7 Page V2-T2-187.

Product Selection

2

Additional Product Selection information begins on Page V2-T2-189.

2

Single-Phase—Type EPZ, 60 Hz

2

480 Volts to 120/240 Volts

2

kVA

FCAN

FCBN

Type

2

0.05

—

—

EPZ

115

FR57H

2

0.75

—

—

EPZ

115

FR58H

1

—

—

EPZ

115

FR59H

2

1.5

—

—

EPZ

115

2

—

—

EPZ

2

3

—

—

2

5

—

7.5

—

2

10

2
2
2
2

Full Capacity Taps

°C Temp.
Rise

Weight
Lbs (kg)

Catalog
Number

524H

13 (6)

Z48N11S51A

524H

21 (10)

Z48N11S76A

524H

31 (14)

Z48N11S01A

FR67H

524H

40 (18)

Z48N11S16A

115

FR68H

524H

40 (18)

Z48N11S02A

EPZ

115

FR176H

524H

65 (30)

Z48N11S03A

—

EPZ

115

FR177H

524H

113 (51)

Z48N11S05A

—

EPZ

115

FR178H

524H

123 (56)

Z48N11S07A

—

—

EPZ

115

FR179H

524H

193 (88)

Z48N11S10A

15

—

—

EPZ

115

FR180H

524H

216 (98)

Z48N11S15A

25

—

—

EPZ

115

FR182H

524H

375 (170)

Z48N11S25A

Catalog
Number

Frame

Wiring Diagram
Number

Three-Phase—Type EPTZ, 60 Hz

480 Delta Volts to 208Y/120 Volts Three-Phase
Full Capacity Taps
kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

3

—

2 at –5%

EPTZ

115

FR201H

70A

116 (53)

Z48G28T03A

2

6

—

2 at –5%

EPTZ

115

FR200H

70A

143 (65)

Z48G28T06A

2

9

—

2 at –5%

EPTZ

115

FR103H

70A

166 (75)

Z48G28T09A

15

—

2 at –5%

EPTZ

115

FR95H

70A

275 (125)

Z48G28T15A

2

30

—

2 at –5%

EPTZ

115

FR243H

66A

422 (191)

Z48G28T30A

45

—

2 at –5%

EPTZ

115

FR244H

66A

660 (299)

Z48G28T45A

2

75

—

2 at –5%

EPTZ

115

FR245H

66A

1275 (580)

Z48G28T75A 1

2

2
2

480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on B Phase 2
Full Capacity Taps
kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

6

—

2 at –5%

EPTZ

115

FR102H

95A

115 (52)

Z48G22T06A

2

9

—

2 at –5%

EPTZ

115

FR97H

95A

160 (73)

Z48G22T09A

15

—

2 at –5%

EPTZ

115

FR195H

95A

340 (155)

Z48G22T15A

2

30

—

2 at –5%

EPTZ

115

FR243H

62A

422 (191)

Z48G22T30A

45

—

2 at –5%

EPTZ

115

FR244H

62A

660 (299)

Z48G22T45A

2

2
2
2

Wiring Diagram
Number

Weight
Lbs (kg)

Catalog
Number

Notes
1 Floor-mount only.
2 Center Tap capacity limited to 5% of rated kVA.
For 316 grade stainless steel enclosure, replace 10th character of catalog number with an “SS” suffix. Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or
catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
V2-T2-128

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Accessories
Please refer to Section 2.7 Page V2-T2-191.

2

Technical Data and Specifications

2

Frequency
Eaton standard dry-type
distribution transformers are
designed for 60 Hz operation.
Transformers required for
other frequencies are
available and must be
specifically designed.
Overload Capability
Short-term overload is
designed into transformers as
required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour, and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250 for
additional limitations.
Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.

Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:
Insulation System
Classification

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

40°C

80°C

30°C

150°C

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

40°C

150°C

30°C

220°C

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.
Enclosures
Eaton encapsulated
transformers, Types EPZ
and EPTZ, use a NEMA 3R
rated enclosure.

Sound Levels
All Eaton 600 volt class
general-purpose dry-type
distribution transformers are
designed to meet NEMA
ST-20 sound levels listed
here. These are the sound
levels measured in a
soundproof environment.
Actual sound levels
measured at an installation
will likely be higher due to
electrical connections and
environmental conditions.
Lower sound levels are
available and should be
specified when the
transformer is going to be
installed in an area where
sound may be a concern.
Winding Terminations
Lugs are not supplied with
these transformers. Eaton
recommends that external
cables be rated 90°C
sized at 75°C ampacity) for
encapsulated designs and
75°C for ventilated designs.

Series-Multiple Windings
Series-multiple windings
consist of two similar coils in
each winding that can be
connected in series or parallel
(multiple). Transformers with
series-multiple windings are
designated with an “x” or
“/” between the voltage
ratings, such as voltages of
“120/240” or “240 x 480.”
If the series-multiple winding
is designated by an “x,” the
winding can be connected
only for a series or parallel.
With the “/” designation, a
mid-point also becomes
available in addition to the
series or parallel connection.
As an example, a 120 x 240
winding can be connected
for either 120 (parallel) or
240 (series), but a 120/240
winding can be connected for
120 (parallel), 240 (series) or
240 with a 120 mid-point.

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Nominal and tap leads come
out of the transformer through
pipe elbows. Connections
should be made to an adjacent
explosion-proof junction box.
Unused tap leads must be
properly insulated prior to
energization. EPZ and EPTZ
transformers are UL and
cUL listed.

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-129

2.5

Transformers
Distribution Transformers

Contents

2

Description

2

Page

Motor Drive Isolation Transformers. . . . . . . . . . . .
Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . .
Totally Enclosed Non-Ventilated Transformers . . .
Class I, Division 2, Hazardous Location Transformers
Open-Type Core and Coil Assembly Transformers
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection. . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Marine Duty Transformers . . . . . . . . . . . . . . . . . .
Buck-Boost and Low Voltage Lighting Transformers
Medium Voltage Distribution Transformers. . . . . .

2
2
2
2
2
2

V2-T2-111
V2-T2-119
V2-T2-124
V2-T2-127
V2-T2-131
V2-T2-131
V2-T2-132
V2-T2-132
V2-T2-133
V2-T2-144
V2-T2-173

2
2
2

Open-Type Core and Coil Assembly Transformers

2

Product Description

2
2
2
2

Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.
●

2
2

●

220°C insulation system;
150°C rise standard;
115°C or 80°C optional
Aluminum windings
(copper optional)

2

Application Description
The basic purpose of a
transformer is voltage
transformation as near as
practically possible to the
load for economy and
distribution of power.
Typical loads for dry-type
distribution transformers
include lighting, heating, air
conditioners, fans and
machine tools. Such loads
are found in commercial,
institutional, industrial and
residential structures.

Features, Benefits
and Functions
●

●

●

60 Hz operation standard,
50/60 Hz operation
available
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels

Open core and coil
assemblies are typically
used by panel builders and
equipment OEM customers
who incorporate the entire
transformer into their
structures, making these
assemblies a versatile option
to purchasing a standard,
enclosed transformer and
discarding the unneeded
enclosure parts.

2
2
2
2
2
2
2
2
2
2
2
V2-T2-130

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Standards and Certifications
●

UL recognized

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards.
Seismically Qualified
All Eaton manufactured drytype distribution transformers
are seismically qualified and
exceed requirements of the
International Building Code
and California Code Title 24.

2.5

Transformers
Distribution Transformers

Catalog Number Selection
Please refer to Section 2.7 Page V2-T2-187.

2

Product Selection

2

Additional Product Selection information begins on Page V2-T2-189.

2

Single-Phase—Type DS-3C, 60 Hz

2
2

240 x 480 Volts to 120/240 Volts
Full Capacity Taps
kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Catalog Number

15

1

1

DS-3C

150

CS15G103

3XA

246 (112)

T20P11S15EEZZ

25

1

1

DS-3C

150

CS25E103

3XA

359 (163)

T20P11S25EEZZ

37.5

1

1

DS-3C

150

CS37C103

3XA

374 (170)

T20P11S37EEZZ

50

1

1

DS-3C

150

CS50G103

3XA

555 (252)

T20P11S50EEZZ

2
2
2
2
2

Three-Phase—Type DT-3C, 60 Hz

2

480 Delta Volts to 208Y/120 Volts
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3C

150

CT15H103

280B

191 (87)

V48M28T15EEZZ

30

2 at +2.5%

4 at –2.5%

DT-3C

150

CT30E103

280B

251 (114)

V48M28T30EEZZ

45

2 at +2.5%

4 at –2.5%

DT-3C

150

CT45E103

280B

367 (167)

V48M28T45EEZZ

75

2 at +2.5%

4 at –2.5%

DT-3C

150

CT75E103

280B

491 (223)

V48M28T75EEZZ

112.5

2 at +2.5%

4 at –2.5%

DT-3C

150

—

280B

676 (307)

V48M28T12EEZZ

150

2 at +2.5%

4 at –2.5%

DT-3C

150

—

280B

796 (362)

V48M28T49EEZZ

2
2
2
2

Notes
1 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary.

2

Contact your local Eaton sales office for availability of additional open-type core and coil assemblies. Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or
catalog numbers not shown, refer to Eaton. Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-131

2.5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Transformers
Distribution Transformers

Accessories
Please refer to Section 2.7 Page V2-T2-191.

Technical Data and Specifications
Frequency
Eaton standard dry-type
distribution transformers are
designed for 60 Hz operation.
Transformers required
for other frequencies are
available and must be
specifically designed.
Overload Capability
Short-term overload is
designed into transformers
as required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour, and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250
for additional limitations.
Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.

2
2
2

Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:
Insulation System
Classification

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

40°C

80°C

30°C

150°C

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

40°C

150°C

30°C

220°C

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.
Winding Terminations
Lugs are not supplied with
these transformers. Eaton
recommends that external
cables be rated 90°C
(sized at 75°C ampacity) for
encapsulated designs and
75°C for ventilated designs.

Series-Multiple Windings
Series-multiple windings
consist of two similar coils in
each winding that can be
connected in series or parallel
(multiple). Transformers with
series-multiple windings are
designated with an “x” or “/”
between the voltage ratings,
such as voltages of “120/240”
or “240 x 480.” If the seriesmultiple winding is designated
by an “x,” the winding can
be connected only for a
series or parallel. With the “/”
designation, a mid-point also
becomes available in addition
to the series or parallel
connection. As an example,
a 120 x 240 winding can
be connected for either
120 (parallel) or 240 (series),
but a 120/240 winding can be
connected for 120 (parallel),
240 (series) or 240 with a
120 mid-point.

Sound Levels
All Eaton 600 volt class
general-purpose dry-type
distribution transformers are
designed to meet NEMA
ST-20 sound levels listed
here. These are the sound
levels measured in a
soundproof environment.
Actual sound levels
measured at an installation
will likely be higher due to
electrical connections and
environmental conditions.
Lower sound levels are
available and should be
specified when the
transformer is going to be
installed in an area where
sound may be a concern.
For additional information,
please refer to Section 2.7
Page V2-T2-195.

Average Sound Levels
NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

Encapsulated
(up to 1.2 kV)

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

9.01 to 15.00

45

45

50

2

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

2

50.01 to 75.00

50

53

55

75.01 to 112.50

50

53

55

2

112.51 to 150.00

50

53

55

2

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

2

300.01 to 500.00

60

63

59

500.01 to 700.00

62

65

61

2

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

2
2
2
2
2
V2-T2-132

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Contents
Description

Page

Motor Drive Isolation Transformers . . . . . . . . . . . .
Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . .
Totally Enclosed Non-Ventilated Transformers. . . .
Class I, Division 2, Hazardous Location Transformers
Open-Type Core and Coil Assembly Transformers
Marine Duty Transformers
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications. . . . . . . . . . .
Buck-Boost and Low Voltage Lighting Transformers
Medium Voltage Distribution Transformers . . . . . .

V2-T2-111
V2-T2-119
V2-T2-124
V2-T2-127
V2-T2-130
V2-T2-134
V2-T2-134
V2-T2-143
V2-T2-143
V2-T2-144
V2-T2-173

2
2
2
2
2
2
2
2
2
2
2

Marine Duty Transformers
Product Description
Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.

Types EP, EPT
● Encapsulated design
● Suitable for indoor or
outdoor applications
● Totally enclosed, nonventilated enclosures
● Enclosures are NEMA 3R
rated
● Mountable in any position
indoors and upright-only
outdoors
● 180ºC insulation system
● 115ºC rise standard; 80°C
rise optional
● Copper windings standard
● Available in singlephase ratings through
37.5 kVA (EP)
● Available in threephase ratings through
75 kVA (EPT)

Types DS-3, DT-3
Ventilated, NEMA 2
enclosure standard
● Suitable for indoor
applications; outdoors
when weathershields
are also installed
● Upright mounting only
● 220ºC insulation system
● 115ºC rise standard; 150°C
or 80°C rise optional
● Copper windings standard
● Available in single-phase
ratings 15–167 kVA
and up to 4160 volts
primary (DS-3)
● Available in three-phase
ratings 15–1500 kVA
and up to 4160 volts
primary (DT-3)
●

Application Description

Standards and Certifications

The basic purpose of a
transformer is voltage
transformation as near as
practically possible to the
load for economy and
distribution of power.
Typical loads for dry-type
distribution transformers
include lighting, heating,
air conditioners, fans and
machine tools. Such loads
are found in commercial,
institutional, industrial and
residential structures.

●

UL listed

2
2

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards. All
600 volt class transformers
are UL listed unless
otherwise noted.

Features, Benefits
and Functions
●

●

●
●

●
●

●

2

2
2
2
2
2
2

Meets ABS (American
Bureau of Shipping)
specification
ABS Type Approval
Certificate Number
04-TP517621-X
60 Hz operation
115°C temperature
rise standard
Copper windings standard
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels

2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-133

2.5
2
2

Transformers
Distribution Transformers

Catalog Number Selection
Please refer to Section 2.7 Page V2-T2-187.

Product Selection

2

Additional Product Selection information begins on Page V2-T2-189.

2

Single-Phase—Type EPM Marine Duty Encapsulated NEMA 3R, 60 Hz

2

240 x 480 Volts to 120/240 Volts—Copper Windings

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

0.05

None

None

EPM

115

FR52

3A050Q

7 (3)

—

QS20N11S81CU

0.075

None

None

EPM

115

FR54

3A075Q

7 (3)

—

QS20N11S85CU

2

0.1

None

None

EPM

115

FR54

3A100Q

7 (3)

—

QS20N11S82CU

2

0.15

None

None

EPM

115

FR55

3A150Q

8 (4)

—

QS20N11S83CU

0.25

None

None

EPM

115

FR56

3A250Q

12 (5)

—

QS20N11S26CU

2

0.5

None

None

EPM

115

FR57

3A500Q

13 (6)

—

QS20N11S51CU

0.75

None

None

EPM

115

FR58A

3A750Q

21 (10)

—

QS20N11S76CU

2

1

None

None

EPM

115

FR59A

3A1Q

31 (14)

—

QS20N11S01CU

2

1.5

None

None

EPM

115

FR67

3A16Q

40 (18)

—

QS20N11S16CU

2

None

None

EPM

115

FR68

3A2Q

40 (18)

—

QS20N11S02CU

2

3

None

None

EPM

115

FR176

3A3Q

72 (33)

—

QS20N11S03CU

5

None

None

EPM

115

FR177

3A5Q

125 (57)

—

QS20N11S05CU

2

7.5

None

None

EPM

115

FR178

3A7Q

135 (61)

—

QS20N11S07CU

10

None

None

EPM

115

FR179

3A10Q

203 (92)

—

QS20N11S10CU

2

15

None

None

EPM

115

FR182

3A15Q

231 (105)

—

QS20N11S15CU

2

25

None

None

EPM

115

FR300A

128A25Q

380 (173)

—

QS20N11S25CU

37.5

None

None

EPM

115

FR300A

248A37Q

856 (389)

—

QS20L11S37CU

2

2

Full Capacity Taps

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-134

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.5

Transformers
Distribution Transformers

Single-Phase—Type DS-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1

2
2

120 Volts to 120 Volts—Copper Windings
Full Capacity Taps
kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DS-3M

115

816

56D15R

275 (125)

WS11

RT12M12F15CUEE

25

2 at +2.5%

4 at –2.5%

DS-3M

115

818

56D25R

440 (200)

WS11

RT12M12F25CUEE

37.5

2 at +2.5%

4 at –2.5%

DS-3M

115

818

56D37R

480 (218)

WS11

RT12M12F37CUEE

50

2 at +2.5%

4 at –2.5%

DS-3M

115

819

56D50R

725 (329)

WS16

RT12M12F50CUEE

75

2 at +2.5%

4 at –2.5%

DS-3M

115

820

56D75R

820 (372)

WS16

RT12M11F75CUEE

100

2 at +2.5%

4 at –2.5%

DS-3M

115

821

56D100R

1150 (522)

WS13

RT12M11F99CUEE

Full Capacity Taps
FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DS-3M

115

816

260A15R

275 (125)

WS11

RT29M11F15CUEE

25

2 at +2.5%

4 at –2.5%

DS-3M

115

818

260A25R

440 (200)

WS11

RT29M11F25CUEE

37.5

2 at +2.5%

4 at –2.5%

DS-3M

115

818

260A37R

480 (218)

WS11

RT29M11F37CUEE

50

2 at +2.5%

4 at –2.5%

DS-3M

115

819

260A50R

725 (329)

WS16

RT29M11F50CUEE

75

1 at +5%

2 at –5%

DS-3M

115

820

260A75R

820 (372)

WS16

RT29R11F75CUEE

100

1 at +5%

2 at –5%

DS-3M

115

821

260A100R

1150 (522)

WS13

RT29R11F99CUEE

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2

2

DS-3M

115

816

3XA15R

264 (120)

WS11

RT20P11F15CUEE

25

2

2

DS-3M

115

818

3XA25R

420 (191)

WS11

RT20P11F25CUEE

37.5

2

2

DS-3M

115

818

3XA37R

450 (204)

WS11

RT20P11F37CUEE

50

2

2

DS-3M

115

819

3XA50R

703 (319)

WS16

RT20P11F50CUEE

75

2

2

DS-3M

115

820

3XA75R

793 (360)

WS16

RT20P11F75CUEE

100

2

2

DS-3M

115

821

3XA100R

1085 (493)

WS13

RT20P11F99CUEE

2
2
2
2
2
2
2
2
2
2
2
2
2

277 Volts to 120/240 Volts—Copper Windings
Full Capacity Taps

2

2

240 x 480 Volts to 120/240 Volts—Copper Windings
Full Capacity Taps

2

2

208 Volts to 120/240 Volts—Copper Windings
kVA

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DS-3M

115

816

262C15R

275 (125)

WS11

RT27M11F15CUEE

25

2 at +2.5%

4 at –2.5%

DS-3M

115

818

262C25R

440 (200)

WS11

RT27M11F25CUEE

37.5

2 at +2.5%

4 at –2.5%

DS-3M

115

818

262C37R

480 (218)

WS11

RT27M11F37CUEE

50

2 at +2.5%

4 at –2.5%

DS-3M

115

819

262C50R

725 (329)

WS16

RT27M11F50CUEE

75

1 at +5%

2 at –5%

DS-3M

115

820

262C75R

820 (372)

WS16

RT27M11F75CUEE

100

1 at +5%

2 at –5%

DS-3M

115

821

262C100R

1150 (522)

WS13

RT27M11F99CUEE

Notes
1 Suitable for installation in onshore, onboard or offshore applications.
2 1 at +5%, 2 at –5% at 240 volts primary; 2 at +2.5%, 4 at –2.5% at 480 volts primary.

2
2
2
2
2
2
2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-135

2.5
2

Transformers
Distribution Transformers

Single-Phase—Type DS-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1

2

208 x 416 Volts to 120/240 Volts—Copper Windings

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2

2

DS-3M

115

816

3XF15R

264 (120)

WS11

RT18P11F15CUEE

25

2

2

DS-3M

115

818

3XF25R

420 (191)

WS11

RT18P11F25CUEE

2

37.5

2

2

DS-3M

115

818

3XF37R

450 (204)

WS11

RT18P11F37CUEE

2

50

2

2

DS-3M

115

819

3XF50R

703 (319)

WS16

RT18P11F50CUEE

75

2

2

DS-3M

115

820

3XF75R

793 (360)

WS16

RT18P11F75CUEE

100

2

2

DS-3M

115

821

3XF100R

1085 (493)

WS13

RT18P11F99CUEE

2

2

Full Capacity Taps

2

600 Volts to 120/240 Volts—Copper Windings

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DS-3M

115

816

262B15R

275 (125)

WS11

RT60M11F15CUEE

2

25

2 at +2.5%

4 at –2.5%

DS-3M

115

818

262B25R

440 (200)

WS11

RT60M11F25CUEE

37.5

2 at +2.5%

4 at –2.5%

DS-3M

115

818

262B37R

480 (218)

WS11

RT60M11F37CUEE

2

50

2 at +2.5%

4 at –2.5%

DS-3M

115

819

262B50R

725 (329)

WS16

RT60M11F50CUEE

75

1 at +5%

2 at –5%

DS-3M

115

820

262B75R

820 (372)

WS16

RT60M11F75CUEE

2

100

1 at +5%

2 at –5%

DS-3M

115

821

262B100R

1150 (522)

WS13

RT60M11F99CUEE

Full Capacity Taps

2

Notes
1 Suitable for installation in onshore, onboard or offshore applications.
2 1 at +5%, 2 at –5% at 208 volts primary; 2 at +2.5%, 4 at –2.5% at 416 volts primary.

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-136

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.5

Transformers
Distribution Transformers

Three-Phase—Type EPTM Marine Duty Encapsulated NEMA 3R, 60 Hz

2
2

480 Delta Volts to 208Y/120 Volts—Copper Windings
Full Capacity Taps
kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

None

2 at –5%

EPTM

115

FR201

70A

132 (60)

—

LY48G28T03CU 1

6

None

2 at –5%

EPTM

115

FR200

70A

182 (83)

—

LY48G28T06CU 1

9

2 at +2.5%

2 at –2.5%

EPTM

115

FR103

72B

221 (100)

—

LY48D28T09CU 1

15

2 at +2.5%

2 at –2.5%

EPTM

115

FR95

72B

296 (135)

—

LY48D28T15CU 1

30

2 at +2.5%

4 at –2.5%

EPTM

115

FR243

84A

612 (278)

—

LY48M28T30CU

45

2 at +2.5%

4 at –2.5%

EPTM

115

FR244

84A

808 (367)

—

LY48M28T45CU

75

2 at +2.5%

4 at –2.5%

EPTM

115

FR245

84A

1450 (659)

—

LY48M28T75CU

2
2
2
2
2
2
2

480 Delta Volts to 240 Delta Volts—Copper Windings
Full Capacity Taps
kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

3

None

2 at –5%

EPTM

115

FR201

74A

132 (60)

—

LY48G24T03CU 1

6

None

2 at –5%

EPTM

115

FR200

74A

182 (83)

—

LY48G24T06CU 1

9

None

2 at –5%

EPTM

115

FR103

74A

221 (100)

—

LY48G24T09CU 1

15

2 at +2.5%

2 at –2.5%

EPTM

115

FR243

230A

612 (278)

—

LY48D24T15CU 1

2
2
2

Three-Phase—Type DT-3M Marine Duty Ventilated NEMA 2, 60 Hz (NEMA 3R with Weathershield Kit Installed)

2
2

480 Delta Volts to 208Y/120 Volts—Copper Windings 2
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280B15M

252 (114)

WS38

MV48M28F15CU

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280B30M

299 (136)

WS38

MV48M28F30CU

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280B45M

414 (188)

WS38

MV48M28F45CU

75

2 at +2.5%

4 at –2.5%

DT-3M

115

915F

280B75M

662 (301)

WS39

MV48M28F75CU

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280B112M

927 (421)

WS19

MV48M28F12CU

150

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280B49M

994 (451)

WS19

MV48M28F49CU

225

2 at +2.5%

4 at –2.5%

DT-3M

115

917

280B22M

1839 (835)

WS34

MV48M28F22CU

300

2 at +2.5%

4 at –2.5%

DT-3M

115

918A

280B33M

2134 (969)

WS34

MV48M28F33CU

500

2 at +2.5%

2 at –2.5%

DT-3M

115

919E

275A55M

3349 (1520)

WS35

MV48M28F55CU

15

2 at +2.5%

4 at –2.5%

DT-3M

80

912D

280B15M

295 (134)

WS38

MV48M28B15CU

30

2 at +2.5%

4 at –2.5%

DT-3M

80

912D

280B30M

367 (167)

WS38

MV48M28B30CU

45

2 at +2.5%

4 at –2.5%

DT-3M

80

915F

280B45M

585 (266)

WS39

MV48M28B45CU

75

2 at +2.5%

4 at –2.5%

DT-3M

80

916A

280B75M

903 (410)

WS19

MV48M28B75CU

112.5

2 at +2.5%

4 at –2.5%

DT-3M

80

916A

280B112M

959 (435)

WS19

MV48M28B12CU

150

2 at +2.5%

4 at –2.5%

DT-3M

80

917

280B49M

1250 (568)

WS34

MV48M28B49CU

225

2 at +2.5%

4 at –2.5%

DT-3M

80

918A

280B22M

1861 (845)

WS34

MV48M28B22CU

300

2 at +2.5%

4 at –2.5%

DT-3M

80

919E

280B33M

3600 (1634)

WS19

MV48M28B33CU

Notes
1 T-T (Scott T) connected secondary.
2 Not suitable for installation on U.S. or U.S. territory soil. Suitable for offshore or onboard applications.

2
2
2
2
2
2
2
2
2
2
2
2
2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-137

2.5
2

Transformers
Distribution Transformers

Three-Phase—Type DT-3M Marine Duty Ventilated NEMA 2, 60 Hz (NEMA 3R with Weathershield Kit Installed)

2

480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap—Copper Windings 1

2

kVA

2

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

282B15M

252 (114)

WS38

MV48M22F15CU

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

282B30M

301 (137)

WS38

MV48M22F30CU

2
2
2
2
2

Full Capacity Taps
FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

282B45M

382 (173)

WS38

MV48M22F45CU

75

2 at +2.5%

4 at –2.5%

DT-3M

115

915F

282B75M

550 (250)

WS39

MV48M22F75CU

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

282B112M

675 (306)

WS19

MV48M22F12CU

150

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

282B49M

860 (390)

WS19

MV48M22F49CU
MV48M22F22CU

225

2 at +2.5%

4 at –2.5%

DT-3M

115

917

282B22M

1839 (835)

WS34

300

2 at +2.5%

4 at –2.5%

DT-3M

115

918A

282B33M

2134 (969)

WS34

MV48M22F33CU

500

2 at +2.5%

2 at –2.5%

DT-3M

115

919E

293A55M

3349 (1520)

WS35

MV48D22F55CU

2

480 Delta Volts to 120 Delta Volts—Copper Windings 1

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

295B15M

252 (114)

WS38

MV48M12F15CU

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

295B30M

301 (137)

WS38

MV48M12F30CU

2

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

295B45M

382 (173)

WS38

MV48M12F45CU

75

2 at +2.5%

4 at –2.5%

DT-3M

115

915F

295B75M

550 (250)

WS39

MV48M12F75CU

Full Capacity Taps

2
2

Three-Phase—Type DT-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient

2

208 Delta Volts to 208Y/120 Volts—Copper Windings 2

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280E15M

265 (120)

WS38

MV29M28F15CUEE

2

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280E30M

475 (215)

WS38

MV29M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280E45M

475 (216)

WS38

MV29M28F45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

280E75M

700 (318)

WS39

MV29M28F75CUEE

112.5

1 at +5%

2 at –5%

DT-3M

115

916A

280E112M

935 (424)

WS19

MV29M28F12CUEE

2

150

1 at +5%

2 at –5%

DT-3M

115

916A

280E150M

1274 (578)

WS19

MV29M28F49CUEE

2

225

1 at +5%

2 at –5%

DT-3M

115

917

280E225M

1743 (791)

WS34

MV29M28F22CUEE

300

1 at +5%

2 at –5%

DT-3M

115

919E

280E300M

2350 (1067)

WS35

MV29M28F33CUEE

500

1 at +5%

2 at –5%

DT-3M

115

920E

280E500M

3690 (1675)

WS35

MV29M28F55CUEE

2

2
2
2

Full Capacity Taps

Notes
1 Not suitable for installation on U.S. or U.S. territory soil. Suitable for offshore or onboard applications.
2 Suitable for installation in onshore, onboard or offshore applications.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
V2-T2-138

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.5

Transformers
Distribution Transformers

Three-Phase—Type DT-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1

2
2

208 Delta Volts to 480Y/277 Volts—Copper Windings
Full Capacity Taps
kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

342B15M

265 (120)

WS38

MV29M47F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

342B30M

475 (215)

WS38

MV29M47F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

342B45M

475 (216)

WS38

MV29M47F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

342B75M

700 (318)

WS39

MV29M47F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

342B112M

935 (424)

WS19

MV29M47F12CUEE

150

1 at +5%

2 at –5%

DT-3M

115

916A

351A150M

1274 (578)

WS19

MV29R47F49CUEE

225

1 at +5%

2 at –5%

DT-3M

115

917

333B225M

1743 (791)

WS34

MV29R47F22CUEE

300

1 at +5%

2 at –5%

DT-3M

115

919E

333B300M

2350 (1067)

WS35

MV29R47F33CUEE

500

1 at +5%

2 at –5%

DT-3M

115

920E

333B500M

3690 (1675)

WS35

MV29R47F55CUEE

Weight
Lbs (kg)

Weathershield

Catalog Number

2
2
2
2
2
2
2

240 Delta Volts to 208Y/120 Volts—Copper Windings
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280C15M

265 (120)

WS38

MV24M28F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280C30M

475 (215)

WS38

MV24M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280C45M

475 (216)

WS38

MV24M28F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

280C75M

700 (318)

WS39

MV24M28F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280C112M

1009 (458)

WS19

MV24M28F12CUEE

150

1 at +5%

2 at –5%

DT-3M

115

916A

289A150M

1274 (578)

WS19

MV24R28F49CUEE

225

1 at +5%

2 at –5%

DT-3M

115

917

289A225M

1743 (791)

WS34

MV24R28F22CUEE

300

1 at +5%

2 at –5%

DT-3M

115

919E

289A300M

2350 (1067)

WS35

MV24R28F33CUEE

500

1 at +5%

2 at –5%

DT-3M

115

920E

289A500M

3690 (1675)

WS35

MV24R28F55CUEE

2
2
2
2
2
2
2

240 Delta Volts to 480Y/277 Volts—Copper Windings
Full Capacity Taps

Weight
Lbs (kg)

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

342L15M

265 (120)

WS38

MV24M47F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

342L30M

475 (215)

WS38

MV24M47F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

342L45M

475 (216)

WS38

MV24M47F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

342L75M

700 (318)

WS39

MV24M47F75CUEE

112.5

1 at +5%

2 at –5%

DT-3M

115

916A

351C112M

1009 (458)

WS19

MV24R47F12CUEE

150

1 at +5%

2 at –5%

DT-3M

115

916A

351C150M

1274 (578)

WS19

MV24R47F49CUEE

225

1 at +5%

2 at –5%

DT-3M

115

917

333A225M

1743 (791)

WS34

MV24R47F22CUEE

300

1 at +5%

2 at –5%

DT-3M

115

919E

333A300M

2350 (1067)

WS35

MV24R47F33CUEE

500

1 at +5%

2 at –5%

DT-3M

115

920E

333A500M

3690 (1675)

WS35

MV24R47F55CUEE

2
2
2
2
2
2

Notes
1 Suitable for installation in onshore, onboard or offshore applications.

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-139

2.5
2

Transformers
Distribution Transformers

Three-Phase—Type DT-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1

2

440 Delta Volts to 220Y/127 Volts—Copper Windings

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280J15M

256 (116)

WS38

MV44M31F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280J30M

337 (153)

WS38

MV44M31F30CUEE

2

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280J45M

446 (202)

WS38

MV44M31F45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

280J75M

662 (301)

WS39

MV44M31F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280J112M

914 (415)

WS19

MV44M31F12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280J150M

1132 (514)

WS19

MV44M31F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3M

115

917

280J225M

2036 (924)

WS34

MV44M31F22CUEE

2

300

2 at +2.5%

4 at –2.5%

DT-3M

115

923

275F300M

2325 (1056)

WS37

MV44M31F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3M

115

919E

275F500M

3681 (1671)

WS35

MV44M31F55CUEE

2

2

Full Capacity Taps

2

480 Delta Volts to 208Y/120 Volts—Copper Windings

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280B15M

256 (116)

WS38

MV48M28F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280B30M

337 (153)

WS38

MV48M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280B45M

446 (202)

WS38

MV48M28F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

280B75M

662 (301)

WS39

MV48M28F75CUEE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280B112M

914 (415)

WS19

MV48M28F12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280B150M

1132 (514)

WS19

MV48M28F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3M

115

917

275A225M

2036 (924)

WS34

MV48M28F22CUEE

2
2

2

Full Capacity Taps

300

2 at +2.5%

4 at –2.5%

DT-3M

115

923

275A300M

2325 (1056)

WS37

MV48M28F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3M

115

919E

275A500M

3681 (1671)

WS35

MV48M28F55CUEE

2
2

480 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 2—Copper Windings

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

282B15M

248 (113)

WS38

MV48M22F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

282B30M

410 (186)

WS38

MV48M22F30CUEE

2

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

282B45M

445 (202)

WS38

MV48M22F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

282B75M

750 (341)

WS39

MV48M22F75CUEE

2

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

282B112M

963 (437)

WS19

MV48M22F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

282B150M

1236 (561)

WS19

MV48M22F49CUEE

2

225

2 at +2.5%

4 at –2.5%

DT-3M

115

917

282B225M

2100 (953)

WS34

MV48M22F22CUEE

2

300

2 at +2.5%

4 at –2.5%

DT-3M

115

923

282B300M

2600 (1180)

WS37

MV48M22F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3M

115

919E

291A500M

3700 (1680)

WS35

MV48M22F55CUEE

2
2

Full Capacity Taps

Notes
1 Suitable for installation in onshore, onboard or offshore applications.
2 Lighting tap limited to 5% of nameplate full load capacity.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
V2-T2-140

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.5

Transformers
Distribution Transformers

Three-Phase—Type DT-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1

2
2

480 Delta Volts to 480Y/277 Volts—Copper Windings
Full Capacity Taps
kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280B15M

258 (117)

WS38

MV48M47F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280B30M

401 (182)

WS38

MV48M47F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280B45M

455 (207)

WS38

MV48M47F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

280B75M

678 (308)

WS39

MV48M47F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280B112M

676 (307)

WS19

MV48M47F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280B150M

1249 (567)

WS19

MV48M47F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3M

115

917

275A225M

2107 (957)

WS34

MV48M47F22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3M

115

923

275A300M

2418 (1098)

WS37

MV48M47F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3M

115

919E

275A500M

3800 (1725)

WS35

MV48M47F55CUEE

Weight
Lbs (kg)

Weathershield

Catalog Number

2
2
2
2
2
2
2

600 Delta Volts to 208Y/120 Volts—Copper Windings
Full Capacity Taps

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280A15M

269 (122)

WS38

MV60M28F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280A30M

354 (161)

WS38

MV60M28F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280A45M

468 (213)

WS38

MV60M28F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

280A75M

695 (316)

WS39

MV60M28F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280A112M

960 (436)

WS19

MV60M28F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280A150M

1189 (540)

WS19

MV60M28F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3M

115

917

280A225M

2138 (971)

WS34

MV60M28F22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3M

115

923

280A300M

2441 (1108)

WS37

MV60M28F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3M

115

919E

280A500M

3865 (1755)

WS35

MV60M28F55CUEE

2
2
2
2
2
2
2

600 Delta Volts to 240 Delta Volts with 120 Volt Lighting Tap on Phase B 2—Copper Windings
Full Capacity Taps

Weight
Lbs (kg)

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weathershield

Catalog Number

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

282B15M

269 (122)

WS38

MV60M22F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

282B30M

354 (161)

WS38

MV60M22F30CUEE

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

282B45M

468 (213)

WS38

MV60M22F45CUEE

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

282B75M

695 (316)

WS39

MV60M22F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

282B112M

960 (436)

WS19

MV60M22F12CUEE

150

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

282B150M

1189 (540)

WS19

MV60M22F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3M

115

917

282B225M

2138 (971)

WS34

MV60M22F22CUEE

300

2 at +2.5%

4 at –2.5%

DT-3M

115

923

282B300M

2441 (1108)

WS37

MV60M22F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3M

115

919E

291A500M

3865 (1755)

WS35

MV60M22F55CUEE

2
2
2
2
2
2
2

Notes
1 Suitable for installation in onshore, onboard or offshore applications.
2 Lighting tap limited to 5% of nameplate full load capacity.

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-141

2.5
2

Transformers
Distribution Transformers

Three-Phase—Type DT-3M Marine Duty 60 Hz NEMA TP-1 Energy-Efficient 1

2

600 Delta Volts to 480Y/277 Volts—Copper Windings

2

kVA

FCAN

FCBN

Type

°C Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

15

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280A15M

284 (129)

WS38

MV60M47F15CUEE

30

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280A30M

441 (200)

WS38

MV60M47F30CUEE

2

45

2 at +2.5%

4 at –2.5%

DT-3M

115

912D

280A45M

501 (227)

WS38

MV60M47F45CUEE

2

75

2 at +2.5%

4 at –2.5%

DT-3M

115

914F

280A75M

746 (339)

WS39

MV60M47F75CUEE

112.5

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280A112M

744 (338)

WS19

MV60M47F12CUEE

2

150

2 at +2.5%

4 at –2.5%

DT-3M

115

916A

280A150M

1374 (624)

WS19

MV60M47F49CUEE

225

2 at +2.5%

4 at –2.5%

DT-3M

115

917

280A225M

2318 (1052)

WS34

MV60M47F22CUEE

2

300

2 at +2.5%

4 at –2.5%

DT-3M

115

923

280A300M

2660 (1208)

WS37

MV60M47F33CUEE

500

2 at +2.5%

4 at –2.5%

DT-3M

115

919E

280A500M

4180 (1898)

WS35

MV60M47F55CUEE

2
2

Full Capacity Taps

Notes
1 Suitable for installation in onshore, onboard or offshore applications.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-142

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.5

Transformers
Distribution Transformers

Accessories
Please refer to Section 2.7 Page V2-T2-191.

2

Technical Data and Specifications

2

Frequency
Eaton standard dry-type
distribution transformers are
designed for 60 Hz operation.
Transformers required for
other frequencies are
available and must be
specifically designed.
Overload Capability
Short-term overload is
designed into transformers as
required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour, and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250 for
additional limitations.
Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.
Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:
Insulation System
Classification

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

40°C

80°C

30°C

150°C

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

40°C

150°C

30°C

220°C

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.

Enclosures
Eaton ventilated transformers
Types DS-3M and DT-3M use
a NEMA 2 rated (drip-proof)
enclosure as standard, and
are rated NEMA 3R with the
addition of weathershields.
Eaton encapsulated
transformers Types EPM
and EPTM use a NEMA 3R
rated enclosure.
Winding Terminations
Primary and secondary
windings are terminated
in the wiring compartment.
Encapsulated units have
copper leads or stabs
brought out for connections.
Ventilated transformers
have leads brought out to
aluminum pads that are predrilled to accept Cu/Al lugs.
Lugs are not supplied with
these transformers. Eaton
recommends that external
cables be rated 90°C
(sized at 75°C ampacity) for
encapsulated designs and
75°C for ventilated designs.
Series-Multiple Windings
Series-multiple windings
consist of two similar coils
in each winding that can be
connected in series or parallel
(multiple). Transformers with
series-multiple windings are
designated with an “x” or “/”
between the voltage ratings,
such as voltages of “120/240”
or “240 x 480.” If the seriesmultiple winding is designated
by an “x,” the winding can be
connected only for a series
or parallel. With the “/”
designation, a mid-point also
becomes available in addition
to the series or parallel
connection. As an example,
a 120 x 240 winding can be
connected for either 120
(parallel) or 240 (series), but
a 120/240 winding can be
connected for 120 (parallel),
240 (series) or 240 with
a 120 mid-point.

2

Sound Levels
All Eaton 600 volt class
general-purpose dry-type
distribution transformers are
designed to meet NEMA
ST-20 sound levels listed
here. These are the sound
levels measured in a
soundproof environment.
Actual sound levels
measured at an installation
will likely be higher due to
electrical connections and

environmental conditions.
Lower sound levels are
available and should be
specified when the
transformer is going to be
installed in an area where
sound may be a concern.
For additional information,
please refer to Section 2.7
Page V2-T2-195.

2
2
2
2
2
2
2

Average Sound Levels
NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
K-Factor 1, 4, 9
K-Factor 13, 20
kVA Range

Encapsulated
(up to 1.2 kV)

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

50.01 to 75.00

50

53

55

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

500.01 to 700.00

62

65

61

2
2
2
2
2
2
2
2
2

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-143

2.5
2

Transformers
Distribution Transformers

Contents

Type EP

Description

2

Page

Motor Drive Isolation Transformers. . . . . . . . . . . .
Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . .
Totally Enclosed Non-Ventilated Transformers . . .
Class I, Division 2, Hazardous Location Transformers
Open-Type Core and Coil Assembly Transformers
Marine Duty Transformers . . . . . . . . . . . . . . . . . .
Buck-Boost and Low Voltage Lighting Transformers
Product Selection. . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . .
Medium Voltage Distribution Transformers. . . . . .

2
2
2
2
2
2

V2-T2-111
V2-T2-119
V2-T2-124
V2-T2-127
V2-T2-130
V2-T2-133
V2-T2-145
V2-T2-171
V2-T2-171
V2-T2-172
V2-T2-173

2
2
2

Buck-Boost and Low Voltage Lighting Transformers

2

Product Description

2
2
2
2
2
2
2
2
2
2
2
2

Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.

Types EP, EPT
● Encapsulated design
● Suitable for indoor or
outdoor applications
● Totally enclosed, nonventilated enclosures
● Enclosures are
NEMA 3R rated
● Mountable in any position
indoors and upright-only
outdoors
● 180ºC insulation system
● 115°C rise standard;
80°C rise optional
● Available in single-phase
ratings through 7.5 kVA

Application Description
A buck-boost transformer is
used to provide an economical
method of correcting a lower
or higher voltage rating more
suitable for efficient operation
of electrical equipment.
Type EP buck-boost
transformers are small kVA,
single-phase transformers
with dual primary and dual
secondary windings, and
are usually connected as
autotransformers by using
one unit for single-phase
applications and either two
or three units banked for threephase operation. They are
primarily used for motor
operation and should not be
used for motor control circuits,
to correct fluctuating line
voltage or to obtain a neutral
on a delta system. Buck-boost
transformers are ideally suited
for use with low voltage
lighting systems, such as
outdoor lighting.

Features, Benefits
and Functions
●
●
●

●

60 Hz operation
600 volt class insulation
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels

Standards and Certifications
●
●

UL listed
CSA certified

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards. All
600 volt class transformers
are UL listed unless
otherwise noted.
Seismically Qualified
Eaton-manufactured dry-type
distribution transformers are
seismically qualified, and
exceed requirements of the
International Building Code
(IBC) and California Code
Title 24.

Catalog Number Selection

2

Please refer to Section 2.7
Page V2-T2-187.

2
2
2
2
2
V2-T2-144

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

Product Selection
For quick selection data,
refer to the tables on this
and the following pages.
Selection Requirements
You should have the following
information before selecting a
buck-boost transformer:
Line Voltage
The voltage that you want
to buck (decrease) or boost
(increase). This can be found
by measuring the supply line
voltage with a voltmeter.
Load Voltage
The voltage at which your
equipment is designed to
operate. This is listed on
the nameplate of the
load equipment.
Load Amperes or Load kVA
You do not need to know
both—one or the other is
sufficient for selection
purposes. This information
usually can be found on the
nameplate of the equipment
that you want to operate.
Frequency
The supply line frequency
must be the same as the
frequency of the equipment
to be operated—Eaton’s
buck-boost transformers
operate at 60 Hz only.
Phase
The supply line should be
the same as the equipment
to be operated—either singleor three-phase.
Transformer Interconnection
For three-phase applications,
interconnections of
transformers should be
made in a junction box.
Two or three transformers
may be used depending
on an open delta (2) or
wye (3) connection.

2.5

120 x 240 Volts to 12/24 Volts
5-Step Selector
The tables that follow will
simplify the selection of the
buck-boost transformers.
There are no calculations
needed; simply follow these
five steps:
1. Refer to the table having
the same output voltage
as the equipment you
want to operate. For
example, if you are
installing a 240 volt
6 kVA single-phase
load use selection table
on the page.
2. Select the available line
voltage across the top of
the chart that is closest
to the actual supply
voltage. Therefore, for
example, if the available
line voltage is 213 volts,
use the 212 volt column.
3. Read down the column
until you reach an output
kVA or amps rating equal
to or greater than the
load requirements. Since
6 kVA, in the example, is
not listed, use the next
higher rating, or 7.5 kVA.
4. Read across to the far
left columns for the
catalog number and
quantity of transformers
for your application. In
this case, you will need
one (1) catalog number
S10N06P01P.
5. Connect the buck-boost
transformer(s) you have
selected in accordance
with the connection
diagram specified at the
bottom of the available
line voltage column. In
this example, Diagram
“F” would be used.
Note: For single-phase
connections and three-phase
open delta connections, inputs
and outputs may be reversed.
kVA capacity remains constant.

Additional Product Selection
information begins on
Page V2-T2-189.

kVA

°C Temp. Rise

Frame

Weight Lbs (kg)

Catalog Number

0.05

115

FR52

7 (3)

S10N04A81N

0.10

115

FR54

7 (3)

S10N04A82N

0.15

115

FR55

8 (4)

S10N04A83N

0.25

115

FR57P

12 (5)

S10N04P26P

0.50

115

FR57P

13 (5)

S10N04P51P

0.75

115

FR58AP

21 (10)

S10N04P76P

1

115

FR67P

31 (14)

S10N04P01P

1.5

115

FR67P

40 (18)

S10N04P16P

2

115

FR68P

40 (18)

S10N04P02P

3

115

FR176

65 (29)

S10N04A03N

5

115

FR177

113 (51)

S10N04A05N

7.5

115

FR178

123 (55)

S10N04A07N

2
2
2
2
2
2
2
2
2

120 x 240 Volts to 16/32 Volts
kVA

°C Temp. Rise

Frame

Weight Lbs (kg)

Catalog Number

0.05

115

FR52

7 (3)

S10N06A81N

0.10

115

FR54

7 (3)

S10N06A82N

0.15

115

FR55

8 (4)

S10N06A83N

0.25

115

FR57P

12 (5)

S10N06P26P

0.50

115

FR57P

13 (5)

S10N06P51P

0.75

115

FR58AP

21 (10)

S10N06P76P

1

115

FR67P

31 (14)

S10N06P01P

1.5

115

FR67P

40 (18)

S10N06P16P

2

115

FR68P

40 (18)

S10N06P02P

3

115

FR176

65 (29)

S10N06A03N

5

115

FR177

113 (51)

S10N06A05N

7.5

115

FR178

123 (55)

S10N06A07N

2
2
2
2
2
2
2
2
2

240 x 480 Volts to 24/48 Volts
kVA

°C Temp. Rise

Frame

Weight Lbs (kg)

Catalog Number

0.05

115

FR52

7 (3)

S20N08A81N

0.10

115

FR54

7 (3)

S20N08A82N

0.15

115

FR55

8 (4)

S20N08A83N

0.25

115

FR57P

12 (5)

S20N08P26P

0.50

115

FR57P

13 (5)

S20N08P51P

0.75

115

FR58AP

21 (10)

S20N08P76P

1

115

FR67P

31 (14)

S20N08P01P

1.5

115

FR67P

40 (18)

S20N08P16P

2

115

FR68P

40 (18)

S20N08P02P

3

115

FR176

65 (29)

S20N08A03N

5

115

FR177

113 (51)

S20N08A05N

7.5

115

FR178

123 (55)

S20N08A07N

Note
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-145

2.5

Transformers
Distribution Transformers

2

Single-Phase 115 Volt Output Required, 60 Hz

2

84

91

96

100

Output

Output

Output

Input Available Voltage
102

Units
Required 1

Unit
kVA

Output
kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

1

0.05

—

—

—

—

0.24

2.09

—

—

—

—

S10N04A81N

2

1

0.05

0.13

1.14

0.18

1.56

—

—

0.31

2.70

0.36

3.13

S10N06A81N

2

1

0.10

—

—

—

—

0.48

4.17

—

—

—

—

S10N04A82N

1

0.10

0.26

2.29

0.36

3.12

—

—

0.62

5.41

0.72

6.25

S10N06A82N

2

1

0.15

—

—

—

—

0.72

6.25

—

—

—

—

S10N04A83N

1

0.15

0.39

3.44

0.54

4.69

—

—

0.93

8.12

1.08

9.37

S10N06A83N

2

1

0.25

—

—

—

—

1.2

10.4

—

—

—

—

S10N04P26P

2

1

0.25

0.659

5.73

0.899

7.81

—

—

1.56

13.5

1.8

15.6

S10N06P26P

1

0.50

—

—

—

—

2.4

20.8

—

—

—

—

S10N04P51P

2

1

0.50

1.32

11.5

1.8

15.6

—

—

3.11

27.1

3.59

31.2

S10N06P51P

1

0.75

—

—

—

—

3.6

31.2

—

—

—

—

S10N04P76P

2

1

0.75

1.98

17.2

2.7

23.4

—

—

4.67

40.6

5.39

46.8

S10N06P76P

1

1

—

—

—

—

4.79

41.7

—

—

—

—

S10N04P01P

2

1

1

2.64

22.9

3.59

31.2

—

—

6.23

54.1

7.19

62.5

S10N06P01P

2

1

1.5

—

—

—

—

7.2

62.5

—

—

—

—

S10N04P16P

1

1.5

3.95

34.4

5.39

46.9

—

—

9.34

81.2

10.8

93.7

S10N06P16P

2

1

2

—

—

—

—

9.58

83.3

—

—

—

—

S10N04P02P

1

2

5.27

45.8

7.19

62.5

—

—

12.5

108

14.4

125

S10N06P02P

2

1

3

—

—

—

—

14.37

125.1

—

—

—

—

S10N04A03N

1

3

7.92

68.7

10.77

93.6

—

—

18.69

162.3

21.57

187.5

S10N06A03N

2

1

5

—

—

—

—

23.95

208.5

—

—

—

—

S10N04A05N

2

1

5

13.2

115

18

156

—

—

31.15

270.5

35.95

312.5

S10N06A05N

1

7.5

—

—

—

—

36

312

—

—

—

—

S10N04A07N

1

7.5

19.8

172

27

234

—

—

46.7

406

53.9

468

S10N06A07N

2

2
2
2
2
2

Connection Diagram 2

D

B

B

C

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-146

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Output

A

Transformers
Distribution Transformers

2.5

Single-Phase 115 Volt Output Required, 60 Hz

2

Input Available Voltage

2

105

127

130

138

Units
Required 1

Unit
kVA

Output

Output

Output

Output

146

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

1

0.05

0.48

4.17

0.54

4.58

—

—

0.29

2.5

—

—

S10N04A81N

1

0.05

—

—

—

—

0.41

3.54

—

—

0.23

1.98

S10N06A81N

1

0.10

0.96

8.33

1.1

9.17

—

—

0.58

5.0

—

—

S10N04A82N

1

0.10

—

—

—

—

0.82

7.08

—

—

0.46

3.95

S10N06A82N

1

0.15

1.44

12.5

1.6

13.7

—

—

0.87

7.5

—

—

S10N04A83N

1

0.15

—

—

—

—

1.3

10.6

—

—

0.69

5.93

S10N06A83N

1

0.25

2.39

20.8

2.63

22.9

—

—

1.44

12.5

—

—

S10N04P26P

1

0.25

—

—

—

—

2.03

17.7

—

—

1.14

9.88

S10N06P26P

1

0.50

4.79

41.6

5.27

45.8

—

—

2.87

25

—

—

S10N04P51P

1

0.50

——

—

—

—

4.07

35.4

—

—

2.27

19.8

S10N06P51P

1

0.75

7.19

62.4

7.9

68.7

—

—

4.31

37.5

—

—

S10N04P76P

1

0.75

—

—

—

—

6.1

53.1

—

—

3.41

29.6

S10N06P76P

1

1

9.58

83.3

10.5

91.7

—

—

5.75

50

—

—

S10N04P01P

1

1

—

—

—

—

8.14

70.8

—

—

4.55

39.5

S10N06P01P

1

1.5

14.4

125

15.8

137

—

—

8.62

75

—

—

S10N04P16P

Output

1

1.5

—

—

—

—

12.2

106

—

—

6.82

59.3

S10N06P16P

1

2

19.2

16.7

21.1

183

—

—

11.5

100

—

—

S10N04P02P

1

2

—

—

—

—

16.3

142

—

—

9.10

79.2

S10N06P02P

1

3

28.7

249.9

31.5

275.1

—

—

17.3

150

—

—

S10N04A03N

1

3

—

—

—

—

24.4

212.4

—

—

13.6

118.5

S10N06A03N

1

5

47.9

416.5

52.5

458.5

—

—

28.7

250

—

—

S10N04A05N

1

5

—

—

—

—

40.7

354

—

—

22.7

197.5

S10N06A05N

1

7.5

71.9

624

79

687

—

—

43.1

357

—

—

S10N04A07N

1

7.5

—

—

—

—

61

531

—

—

34.1

296

S10N06A07N

Connection Diagram 2

A

A

A

B

B

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2
2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-147

2.5
2
2

Transformers
Distribution Transformers

Single-Phase 120 Volt Output Required, 60 Hz
Input Available Voltage
88

95

100

104

106

Units
Required 1

Unit
kVA

Output

Output

Output

Output

Output

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

1

0.05

—

—

—

—

0.25

2.09

—

—

—

—

S10N04A81N

2

1

0.05

0.14

1.15

0.19

1.56

—

—

0.33

2.70

0.38

3.13

S10N06A81N

2

1

0.10

—

—

—

—

0.50

4.17

—

—

—

—

S10N04A82N

1

0.10

0.28

2.29

0.38

3.12

—

—

0.65

5.41

0.75

6.25

S10N06A82N

2

1

0.15

—

—

—

—

0.75

6.25

—

—

—

—

S10N04A83N

1

0.15

0.41

3.44

0.56

4.69

—

—

0.98

8.12

1.12

9.37

S10N06A83N

2

1

0.25

—

—

—

—

1.25

10.4

—

—

—

—

S10N04P26P

2

1

0.25

0.687

5.73

0.937

7.81

—

—

1.62

13.5

1.87

15.6

S10N06P26P

1

0.50

—

—

—

—

2.5

20.8

—

—

—

—

S10N04P51P

2

1

0.50

1.37

11.5

1.87

15.6

—

—

3.25

27.1

3.75

31.2

S10N06P51P

1

0.75

—

—

—

—

3.75

31.2

—

—

—

—

S10N04P76P

2

1

0.75

2.06

17.2

2.82

23.4

—

—

4.87

40.6

5.62

46.8

S10N06P76P

1

1

—

—

—

—

5

41.7

—

——

—

—

S10N04P01P

2

1

1

2.75

22.9

3.75

31.2

—

—

6.5

54.1

7.5

62.5

S10N06P01P

2

1

1.5

—

—

—

—

7.5

62.5

—

—

—

—

S10N04P16P

1

1.5

4.12

34.4

5.62

46.9

—

—

9.75

81.2

11.2

93.7

S10N06P16P

2

1

2

—

—

—

—

10

83.3

—

—

—

—

S10N04P02P

1

2

5.5

45.8

7.5

62.5

—

—

13

108

15

125

S10N06P02P

2

1

3

—

—

—

—

15

125.1

—

—

—

—

S10N04A03N

1

3

8.25

68.7

11.25

93.6

—

—

19.5

162.3

22.5

187.5

S10N06A03N

2

1

5

—

—

—

—

25

208.5

—

—

—

—

S10N04A05N

2

1

5

13.75

114.5

18.75

156

—

—

32.5

270.5

37.5

312.5

S10N06A05N

1

7.5

—

—

—

—

37.5

312

—

—

—

—

S10N04A07N

1

7.5

20.6

172

28.2

234

—

—

48.7

406

56.2

468

S10N06A07N

2

2
2
2
2
2

Connection Diagram 2

D

B

B

C

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-148

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

A

Transformers
Distribution Transformers

2.5

Single-Phase 120 Volt Output Required, 60 Hz

2

Input Available Voltage

2

109

132

136

144

Units
Required 1

Unit
kVA

Output

Output

Output

Output

152

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

1

0.05

0.5

4.17

0.55

4.58

—

—

0.3

2.5

—

—

S10N04A81N

Output

1

0.05

—

—

—

—

0.43

3.54

—

—

0.24

1.98

S10N06A81N

1

0.10

1.0

8.33

1.1

9.17

—

—

0.6

5.0

—

—

S10N04A82N

1

0.10

—

—

—

—

0.85

7.08

—

—

0.48

3.95

S10N06A82N

1

0.15

1.5

12.5

1.6

13.7

—

—

0.9

7.5

—

—

S10N04A83N

1

0.15

—

—

—

—

1.27

10.6

—

—

0.71

5.93

S10N06A83N

1

0.25

2.5

20.8

2.75

22.9

—

—

1.5

12.5

—

—

S10N04P26P

1

0.25

—

—

—

—

2.12

17.7

—

—

1.19

9.88

S10N06P26P

1

0.50

5

41.6

5.5

45.8

—

—

3

25

—

—

S10N04P51P

1

0.50

—

—

—

—

4.25

35.4

—

—

2.37

19.8

S10N06P51P

1

0.75

7.5

62.4

8.25

68.7

—

—

4.5

37.5

—

—

S10N04P76P

1

0.75

—

—

—

—

6.37

53.1

—

—

3.56

29.6

S10N06P76P

1

1

10

83.3

11

91.7

—

—

6

50

—

—

S10N04P01P

1

1

—

—

—

—

8.5

70.8

—

—

4.75

39.5

S10N06P01P

1

1.5

15

125

16.5

137

—

—

9

75

—

—

S10N04P16P

1

1.5

—

—

—

—

12.7

106

—

—

7.12

59.3

S10N06P16P

1

2

20

167

22

183

—

—

12

100

—

—

S10N04P02P

1

2

—

—

—

—

17

142

—

—

9.5

79.2

S10N06P02P

1

3

30

249.9

33

275.1

—

—

18

150

—

—

S10N04A03N

1

3

—

—

—

—

25.5

212.4

—

—

14.25

118.5

S10N06A03N

1

5

50

416.5

55

458.5

—

—

30

250

—

—

S10N04A05N

1

5

—

—

—

—

42.5

354

—

—

23.7

197.5

S10N06A05N

1

7.5

75

624

82.5

687

—

—

45

375

—

—

S10N04A07N

1

7.5

—

—

—

—

63.7

531

—

—

35.6

296

S10N06A07N

Connection Diagram 2

A

A

A

B

B

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2
2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-149

2.5

Transformers
Distribution Transformers

2

Single-Phase 230 Volt Output Required, 60 Hz

2

199

203

207

209

216

Output

Output

Output

Output

Input Available Voltage
Units
Required 1

Unit
kVA

Output
kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

1

0.05

—

—

—

—

0.43

1.88

0.48

2.08

—

—

S10N04A81N

2

1

0.05

0.31

1.36

0.36

1.56

—

—

—

—

0.72

3.12

S10N06A81N

2

1

0.10

—

—

—

—

0.86

3.75

0.96

4.17

—

—

S10N04A82N

1

0.10

0.62

2.71

0.72

3.12

—

—

—

—

1.44

6.25

S10N06A82N

2

1

0.15

—

—

—

—

1.29

5.62

1.44

6.25

—

—

S10N04A83N

1

0.15

0.93

4.06

1.08

4.69

—

—

—

—

2.16

9.37

S10N06A83N

2

1

0.25

—

—

—

—

2.15

9.37

2.39

10.4

—

—

S10N04P26P

2

1

0.25

1.55

6.77

1.8

7.81

—

—

—

—

3.59

15.6

S10N06P26P

1

0.50

—

—

—

—

4.31

18.7

4.79

20.8

—

—

S10N04P51P

2

1

0.50

3.11

13.5

3.6

15.6

—

—

—

—

7.19

31.2

S10N06P51P

1

0.75

—

—

—

—

6.46

28.2

7.19

31.2

—

—

S10N04P76P

2

1

0.75

4.66

20.3

5.4

23.4

—

—

—

—

10.8

46.8

S10N06P76P

1

1

—

—

—

—

8.62

37.5

9.58

41.7

—

—

S10N04P01P

2

1

1

6.23

27.1

7.2

31.2

—

—

—

—

14.4

62.5

S10N06P01P

2

1

1.5

—

—

—

—

12.9

56.2

14.4

62.5

—

—

S10N04P16P

1

1.5

9.34

40.6

10.8

46.9

—

—

—

—

21.6

93.7

S10N06P16P

2

1

2

—

—

—

—

17.2

75

19.2

83.3

—

—

S10N04P02P

1

2

12.5

54.2

14.4

62.5

—

—

—

—

28.7

125

S10N06P02P

2

1

3

—

—

—

—

25.8

112.5

28.7

125.1

—

—

S10N04A03N

1

3

18.6

81.3

21.6

93.6

—

—

—

—

43.2

187.5

S10N06A03N

2

1

5

—

—

—

—

43.1

187.5

47.9

208.5

—

—

S10N04A05N

2

1

5

31.1

135.5

36

156

—

—

—

—

72

312.5

S10N06A05N

1

7.5

—

—

—

—

64.6

282

71.9

312

—

—

S10N04A07N

1

7.5

46.6

203

54

234

—

—

—

—

108

468

S10N06A07N

2

2
2
2
2
2

Connection Diagram 2

G

F

G

F

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-150

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

E

Transformers
Distribution Transformers

2.5

Single-Phase 230 Volt Output Required, 60 Hz

2

Input Available Voltage

2

219

242

246

253

Units
Required 1

Unit
kVA

Output

Output

Output

Output

260

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

1

0.05

0.96

4.16

1.0

4.38

—

—

0.53

2.29

—

—

S10N04A81N

Output

1

0.05

—

—

—

—

0.77

3.34

—

—

0.41

1.77

S10N06A81N

1

0.10

1.92

8.33

2.01

8.75

—

—

1.05

4.58

—

—

S10N04A82N

1

0.10

—

—

—

—

1.53

6.67

—

—

0.82

3.54

S10N06A82N

1

0.15

2.87

12.5

3.02

13.1

—

—

1.58

6.87

—

—

S10N04A83N

1

0.15

—

—

—

—

2.3

10.0

—

—

1.22

5.31

S10N06A83N

1

0.25

4.79

20.8

5.03

21.9

—

—

2.63

11.5

—

—

S10N04P26P

1

0.25

—

—

—

—

3.83

16.7

—

—

2.04

8.85

S10N06P26P

1

0.50

9.58

41.6

10.1

43.7

—

—

5.27

22.9

—

—

S10N04P51P

1

0.50

—

—

—

—

7.67

33.3

—

—

4.07

17.7

S10N06P51P

1

0.75

14.4

62.4

15.1

65.6

—

—

7.9

34.4

—

—

S10N04P76P

1

0.75

—

—

—

—

11.5

50

—

—

6.11

26.6

S10N06P76P

1

1

19.2

83.3

20.1

87.5

—

—

10.5

45.8

—

—

S10N04P01P

1

1

—

—

—

—

15.3

66.7

—

—

8.15

35.4

S10N06P01P

1

1.5

28.7

125

30.2

131

—

—

15.8

68.7

—

—

S10N04P16P

1

1.5

—

—

—

—

23

100

—

—

12.2

53.1

S10N06P16P

1

2

38.3

167

40.2

175

—

—

21.1

91.7

—

—

S10N04P02P

1

2

—

—

—

—

30.7

133

—

—

16.3

70.8

S10N06P02P

1

3

57.6

249.9

60.3

262.5

—

—

31.5

137.4

—

—

S10N04A03N

1

3

—

—

—

—

45.9

200.1

—

—

24.4

106.2

S10N06A03N

1

5

96

416.5

100.5

437.5

—

—

52.5

229

—

—

S10N04A05N

1

5

—

—

—

—

76.5

333.5

—

—

40.7

177

S10N06A05N

1

7.5

144

624

151

656

—

—

79

344

—

—

S10N04A07N

1

7.5

—

—

—

—

115

500

—

—

61.1

266

S10N06A07N

Connection Diagram 2

E

E

E

F

F

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2
2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-151

2.5
2
2

Transformers
Distribution Transformers

Single-Phase 240 Volt Output Required, 60 Hz
Input Available Voltage
208

212

216

218

225

Units
Required 1

Unit
kVA

Output

Output

Output

Output

Output

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

1

0.05

—

—

—

—

0.45

1.88

0.5

2.08

—

—

S10N04A81N

2

1

0.05

0.32

1.35

0.38

1.56

—

—

—

—

0.75

3.12

S10N06A81N

2

1

0.10

—

—

—

—

0.9

3.75

1.0

4.17

—

—

S10N04A82N

1

0.10

0.65

2.71

0.75

3.12

—

—

—

—

1.5

6.25

S10N06A82N

2

1

0.15

—

—

—

—

1.35

5.62

1.5

6.25

—

—

S10N04A83N

1

0.15

0.98

4.06

1.12

4.69

—

—

—

—

2.25

9.37

S10N06A83N

2

1

0.25

—

—

—

—

2.25

9.37

2.5

10.4

—

—

S10N04P26P

2

1

0.25

1.62

6.77

1.87

7.81

—

—

—

—

3.75

15.6

S10N06P26P

1

0.50

—

—

—

—

4.5

18.7

5

20.8

—

—

S10N04P51P

2

1

0.50

3.25

13.5

3.75

15.6

—

—

—

—

7.5

31.2

S10N06P51P

1

0.75

—

—

—

—

6.75

28.2

7.5

31.2

—

—

S10N04P76P

2

1

0.75

4.87

20.3

5.62

23.4

—

—

—

—

11.2

46.8

S10N06P76P

1

1

—

—

—

—

9

37.5

10

41.7

—

—

S10N04P01P

2

1

1

6.5

27.1

7.5

31.2

—

—

—

—

15

62.5

S10N06A01

2

1

1.5

—

—

—

—

13.5

56.2

15

62.5

—

—

S10N04P16P

1

1.5

9.75

40.6

11.2

46.9

—

—

—

—

22.5

93.7

S10N06P16P

2

1

2

—

—

—

—

18

75

20

83.3

—

—

S10N04P02P

1

2

13

54.2

15

62.5

—

—

—

—

30

125

S10N06P02P

2

1

3

—

—

—

—

27

112.5

30

125.1

—

—

S10N04A03N

1

3

19.5

81.3

22.5

93.6

—

—

—

—

45

187.5

S10N06A03N

2

1

5

—

—

—

—

45

187

50

208

—

—

S10N04A05N

2

1

5

32.5

135

37.5

156

—

—

—

—

75

312

S10N06A05N

1

7.5

—

—

—

—

67.5

282

75

312

—

—

S10N04A07N

1

7.5

48.7

203

56.2

234

—

—

—

—

112

468

S10N06A07N

2

2
2
2
2
2

Connection Diagram 2

G

F

G

F

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-152

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

E

Transformers
Distribution Transformers

2.5

Single-Phase 240 Volt Output Required, 60 Hz

2

Input Available Voltage

2

229

252

256

264

Units
Required 1

Unit
kVA

Output

Output

Output

Output

272

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

1

0.05

1.0

4.16

1.05

4.38

—

—

0.55

2.29

—

—

S10N04A81N

1

0.05

—

—

—

—

0.8

3.33

—

—

0.42

1.77

S10N06A81N

1

0.10

2.0

8.33

2.1

8.75

—

—

1.1

4.58

—

—

S10N04A82N

1

0.10

—

—

—

—

1.6

6.67

—

—

0.85

3.54

S10N06A82N

1

0.15

3.0

12.5

3.15

13.1

—

—

1.65

6.87

—

—

S10N04A83N

1

0.15

—

—

—

—

2.4

10.0

—

—

1.27

5.31

S10N06A83N

1

0.25

5

20.8

5.25

21.9

—

—

2.75

11.5

—

—

S10N04P26P

1

0.25

—

—

—

—

4

16.7

—

—

2.12

8.85

S10N06P26P

1

0.50

10

41.6

10.5

43.7

—

—

5.5

22.9

—

—

S10N04P51P

1

0.50

—

—

—

—

8

33.3

—

—

4.25

17.7

S10N06P51P

1

0.75

15

62.4

15.7

65.6

—

—

8.25

34.4

—

—

S10N04P76P

1

0.75

—

—

—

—

12

50

—

—

6.37

26.6

S10N06P76P

1

1

20

83.3

21

87.5

—

—

11

45.8

—

—

S10N04P01P

Output

1

1

—

—

—

—

16

66.7

—

—

8.5

35.4

S10N06P01P

1

1.5

30

125

31.5

131

—

—

16.5

68.7

—

—

S10N04P16P

1

1.5

—

—

—

—

24

100

—

—

12.7

53.1

S10N06P16P

1

2

40

167

42

175

—

—

22

91.7

—

—

S10N04P02P

1

2

—

—

—

—

32

133

—

—

17

70.8

S10N06P02P

1

3

60

249.9

63

262.5

—

—

33

137.4

—

—

S10N04A03N

1

3

—

—

—

—

48

200.1

—

—

25.5

106.2

S10N06A03N

1

5

100

416.5

105

437.5

—

—

55

229

—

—

S10N04A05N

1

5

—

—

—

—

80

333

—

—

42.5

177

S10N06A05N

1

7.5

150

624

157

656

—

—

82.5

344

—

—

S10N04A07N

1

7.5

—

—

—

—

120

500

—

—

63.7

266

S10N06A07N

Connection Diagram 2

E

E

E

F

F

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2
2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-153

2.5
2
2

Transformers
Distribution Transformers

Three-Phase Open Delta Connection 230 Volt Output Required, 60 Hz
Input Available Voltage
199

203

207

209

216

Output

Output

Output

Output

Output

Units
Required 1

Unit
kVA

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

2

0.05

—

—

—

—

0.75

1.87

0.83

2.08

—

—

S10N04A81N

2

2

0.05

0.54

1.35

0.62

1.56

—

—

—

—

1.24

3.12

S10N06A81N

2

2

0.10

—

—

—

—

1.49

3.75

1.66

4.17

—

—

S10N04A82N

2

0.10

1.08

2.71

1.24

3.12

—

—

—

—

2.49

6.25

S10N06A82N

2

2

0.15

—

—

—

—

2.24

5.62

2.49

6.25

—

—

S10N04A83N

2

0.15

1.62

4.06

1.87

4.69

—

—

—

—

3.73

9.37

S10N06A83N

2

2

0.25

—

—

—

—

3.3

9.37

4.15

10.4

—

—

S10N04P26P

2

2

0.25

2.7

6.77

3.11

7.81

—

—

—

—

6.22

15.6

S10N06P26P

2

0.50

—

—

—

—

7.47

18.7

8.3

20.8

—

—

S10N04P51P

2

2

0.50

5.39

13.5

6.22

15.6

—

—

—

—

12.4

31.2

S10N06P51P

2

0.75

—

—

—

—

11.2

28.2

12.4

31.2

—

—

S10N04P76P

2

2

0.75

8.09

20.3

9.33

23.4

—

—

—

—

18.7

46.8

S10N06P76P

2

1

—

—

—

—

14.9

37.5

16.6

41.7

—

—

S10N04P01P

2

2

1

10.8

27.1

12.4

31.2

—

—

—

—

24.9

62.5

S10N06P01P

2

2

1.5

—

—

—

—

22.4

56.2

24.9

62.5

—

—

S10N04P16P

2

1.5

16.2

40.6

18.7

46.9

—

—

—

—

37.3

93.7

S10N06P16P

2

2

2

—

—

—

—

29.9

75

33.2

83.3

—

—

S10N04P02P

2

2

21.6

54.2

24.9

62.5

—

—

—

—

49.8

125

S10N06P02P

2

2

3

—

—

—

—

44.7

112.5

49.8

125.1

—

—

S10N04A03N

2

3

32.4

81.3

32.7

93.6

—

—

—

—

74.7

187.5

S10N06A03N

2

2

5

—

—

—

—

74.7

187

83

208

—

—

S10N04A05N

2

2

5

53.9

135

62.2

156

—

—

—

—

124

312.5

S10N06A05N

2

7.5

—

—

—

—

112

282

124

312

—

—

S10N04A07N

2

7.5

80.9

203

93.3

234

—

—

—

—

187

468

S10N06A07N

2

2
2
2
2
2

Connection Diagram 2

L

K

L

K

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-154

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

I

Transformers
Distribution Transformers

2.5

Three-Phase Open Delta Connection 230 Volt Output Required, 60 Hz

2

Input Available Voltage

2

219

242

246

253

Units
Required 1

Unit
kVA

Output

Output

Output

Output

260

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

2

0.05

1.66

4.17

1.74

4.37

—

—

0.91

2.29

—

—

S10N04A81N

2

0.05

—

—

—

—

1.33

3.33

—

—

0.70

1.77

S10N06A81N

2

0.10

3.32

8.33

3.48

8.75

—

—

1.83

4.58

—

—

S10N04A82N

2

0.10

—

—

—

—

2.65

6.67

—

—

1.41

3.54

S10N06A82N

2

0.15

4.98

12.5

5.23

13.1

—

—

2.74

6.87

—

—

S10N04A83N

2

0.15

—

—

—

—

3.98

10.0

—

—

2.12

5.13

S10N06A83N

2

0.25

8.3

20.8

8.71

21.9

—

—

4.56

11.5

—

—

S10N04P26P

2

0.25

—

—

—

—

6.64

16.7

—

—

3.52

8.85

S10N06P26P

Output

2

0.50

16.6

41.7

17.4

43.7

—

—

9.73

22.9

—

—

S10N04P51P

2

0.50

—

—

—

—

13.3

33.3

—

—

7.05

17.7

S10N06P51P

2

0.75

24.9

62.4

26.1

65.6

—

—

13.7

34.4

—

—

S10N04P76P

2

0.75

—

—

—

—

19.9

50

—

—

10.6

26.6

S10N06P76P

2

1

33.2

83.3

34.8

87.5

—

—

18.3

45.8

—

—

S10N04P01P

2

1

—

—

—

—

26.5

66.7

—

—

14.1

35.4

S10N06P01P

2

1.5

49.8

125

52.3

131

—

—

27.4

68.7

—

—

S10N04P16P

2

1.5

—

—

—

—

39.8

100

—

—

21.2

53.1

S10N06P16P

2

2

66.4

167

69.7

175

—

—

36.5

91.7

—

—

S10N04P02P

2

2

—

—

—

—

53.1

133

—

—

28.2

70.8

S10N06P02P

2

3

99.6

249.9

104.4

262.5

—

—

54.9

137.4

—

—

S10N04A03N

2

3

—

—

—

—

79.5

200

—

—

42.3

106.2

S10N06A03N

2

5

166

417

174

437

—

—

91.3

229

—

—

S10N04A05N

2

5

—

—

—

—

133

333

—

—

70.5

177

S10N06A05N

2

7.5

249

624

261

656

—

—

137

344

—

—

S10N04A07N

2

7.5

—

—

—

—

199

500

—

—

106

266

S10N06A07N

Connection Diagram 2

I

I

I

K

K

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2
2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-155

2.5
2
2

Transformers
Distribution Transformers

Three-Phase Open Delta Connection 240 Volt Output Required, 60 Hz
Input Available Voltage
208

212

216

218

Units
Required 1

Unit
kVA

Output

Output

Output

Output

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

2

0.05

—

—

—

—

0.73

1.87

0.87

2.08

—

—

S10N04A81N

2

2

0.05

0.56

1.35

0.65

1.56

—

—

—

—

1.3

3.12

S10N06A81N

2

2

0.10

—

—

—

—

1.56

3.75

1.73

4.17

—

—

S10N04A82N

2

0.10

1.13

2.71

1.3

3.12

—

—

—

—

2.6

6.25

S10N06A82N

2

2

0.15

—

—

—

—

2.34

5.62

2.6

6.25

—

—

S10N04A83N

2

0.15

1.69

4.06

1.95

4.69

—

—

—

—

3.9

9.37

S10N06A83N

2

2

0.25

——

—

—

—

3.9

9.37

4.33

10.4

—

—

S10N04P26P

2

2

0.25

2.81

6.77

3.25

7.81

—

—

—

—

6.49

15.6

S10N06P26P

2

0.50

—

—

—

—

7.79

18.7

8.66

20.8

—

—

S10N04P51P

2

2

0.50

5.63

13.5

6.5

15.6

——

—

—

—

13

31.2

S10N06P51P

2

0.75

—

—

—

—

11.7

28.2

13

31.2

—

—

S10N04P76P

2

2

0.75

8.44

20.3

9.75

23.4

—

—

—

—

19.5

46.8

S10N06P76P

2

1

—

—

—

—

15.6

37.5

17.3

41.7

—

—

S10N04P01P

2

2

1

11.3

27.1

13

31.2

—

—

—

—

26

62.5

S10N06P01P

2

2

1.5

—

—

—

—

23.4

56.2

26

62.5

—

—

S10N04P16P

2

1.5

16.9

40.6

19.5

46.9

—

—

—

—

39

93.7

S10N06P16P

2

2

2

—

—

—

—

31.2

75

34.6

83.3

—

—

S10N04P02P

2

2

22.5

54.2

26

62.5

—

—

—

—

52

125

S10N06P02P

2

2

3

—

—

—

—

46.8

112.5

51.9

125.1

—

—

S10N04A03N

2

3

33.9

81.3

39

93.6

—

—

—

—

78

187.5

S10N06A03N

2

2

5

—

—

—

—

77.9

187

86.6

208

—

—

S10N04A05N

2

2

5

56.3

135

65

156

—

—

—

—

130

312

S10N06A05N

2

7.5

—

—

—

—

117

282

130

312

—

—

S10N04A07N

2

7.5

84.4

203

97.5

234

—

—

—

—

195

468

S10N06A07N

2

2
2
2
2
2

Connection Diagram 2

L

K

L

K

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
V2-T2-156

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

225
Output

I

Transformers
Distribution Transformers

2.5

Three-Phase Open Delta Connection 240 Volt Output Required, 60 Hz

2

Input Available Voltage

2

229

252

256

264

Units
Required 1

Unit
kVA

Output

Output

Output

Output

272

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

2

0.05

1.73

4.16

1.82

4.37

—

—

0.95

2.29

—

—

S10N04A81N

Output

2

0.05

—

—

—

—

1.38

3.33

—

—

0.74

1.77

S10N06A81N

2

0.10

3.46

8.33

3.64

8.75

—

—

1.91

4.58

—

—

S10N04A82N

2

0.10

—

—

—

—

2.77

6.67

—

—

1.47

3.54

S10N06A82N

2

0.15

5.19

12.5

5.45

13.1

—

—

2.86

6.87

—

—

S10N04A83N

2

0.15

—

—

—

—

4.15

10.0

—

—

2.21

5.31

S10N06A83N

2

0.25

8.66

20.8

9.09

21.9

—

—

4.76

11.5

—

—

S10N04P26P

2

0.25

—

—

—

—

6.92

16.7

—

—

3.68

8.85

S10N06P26P

2

0.50

17.3

41.6

18.2

43.7

—

—

9.53

22.9

—

—

S10N04P51P

2

0.50

—

—

—

—

13.8

33.3

—

—

7.36

17.7

S10N06P51P

2

0.75

26

62.4

27.3

65.6

—

—

14.3

34.4

—

—

S10N04P76P

2

0.75

—

—

—

—

20.8

50

—

—

11

26.6

S10N06P76P

2

1

34.6

83.3

36.4

87.5

—

—

19.1

45.8

—

—

S10N04P01P

2

1

—

—

—

—

27.7

66.7

—

—

14.7

35.4

S10N06P01P

2

1.5

51.9

125

54.5

131

—

—

28.6

68.7

—

—

S10N04P16P

2

1.5

—

—

—

—

41.5

100

—

—

22.1

53.1

S10N06P16P

2

2

69.3

167

72.7

175

—

—

38.1

91.7

—

—

S10N04P02P

2

2

—

—

—

—

55.4

133

—

—

29.4

70.8

S10N06P02P

2

3

103.8

249.9

109.2

262.5

—

—

57.3

137.4

—

—

S10N04A03N

2

3

—

—

—

—

83.1

200

—

—

44.1

106.2

S10N06A03N

2

5

173

416

182

437

—

—

95.3

229

—

—

S10N04A05N

2

5

—

—

—

—

138

333

—

—

73.6

177

S10N06A05N

2

7.5

260

624

273

656

—

—

143

344

—

—

S10N04A07N

2

7.5

—

—

—

—

208

500

—

—

110

266

S10N06A07N

Connection Diagram 2

I

I

I

K

K

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2
2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-157

2.5
2
2
2
2
2
2
2

Transformers
Distribution Transformers

WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output

requires four-wire wye input.

Three-Phase Wye Connection 208 Volt Output Required, 60 Hz
Input Available Voltage
152

164

173

180

Units
Required 1

Unit
kVA

Output

Output

Output

Output

184

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

3

0.05

—

—

—

—

0.75

2.08

—

—

—

—

S10N04A81N

Output

3

0.05

0.41

1.15

0.56

1.56

—

—

0.98

2.71

1.12

3.12

S10N06A81N

3

0.10

—

—

—

—

1.50

4.17

—

—

—

—

S10N04A82N

3

0.10

0.82

2.29

1.12

3.12

—

—

1.95

5.41

2.25

6.25

S10N06A82N

2

3

0.15

—

—

—

—

2.25

6.25

—

—

—

—

S10N04A83N

3

0.15

1.24

3.44

1.69

4.69

—

—

2.92

8.12

3.73

9.37

S10N06A83N

2

3

0.25

—

—

—

—

3.75

10.4

—

—

—

—

S10N04P26P
S10N06P26P

3

0.25

2.06

5.73

2.81

7.81

—

—

4.87

13.5

5.62

15.6

2

3

0.50

—

—

—

—

7.5

20.8

—

—

—

—

S10N04P51P

2

3

0.50

4.12

11.5

5.62

15.6

—

—

9.75

27.1

11.2

31.2

S10N06P51P

3

0.75

—

—

—

—

11.2

31.2

—

—

—

—

S10N04P76P

2

3

0.75

6.19

17.2

8.44

23.4

—

—

14.6

40.6

16.8

46.8

S10N06P76P

3

1

—

—

—

—

15

41.7

—

—

—

—

S10N04P01P

2

3

1

8.25

22.9

11.2

31.2

—

—

19.5

54.1

22.5

62.5

S10N06P01P

3

1.5

—

—

—

—

22.5

62.5

—

—

—

—

S10N04P16P

3

1.5

12.4

34.4

16.9

46.9

—

—

29.2

81.2

33.7

93.7

S10N06P16P

3

2

—

—

—

—

30

83.3

—

—

—

—

S10N04P02P

3

2

16.5

45.8

22.5

62.5

—

—

39

108

45

125

S10N06P02P

2
2
2

3

3

—

—

—

—

45

125

—

—

—

—

S10N04A03N

3

3

24.7

68.7

33.6

93.6

—

—

58.5

162.3

67.5

187.5

S10N06A03N

2

3

5

—

—

—

—

75

208

—

—

—

—

S10N04A05N

2

3

5

41.2

115

56.2

156

—

—

97.5

271

112

312

S10N06A05N

3

7.5

—

—

—

—

112

312

—

—

—

—

S10N04A07N

3

7.5

61.9

172

84.4

234

—

—

146

406

168

468

S10N06A07N

2
2
2
2
2

Connection Diagram 2

P

N

N

O

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
V2-T2-158

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

M

Transformers
Distribution Transformers

2.5

WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output

requires four-wire wye input.

2

Three-Phase Wye Connection 208 Volt Output Required, 60 Hz

2

Input Available Voltage
189

229

236

Output

250

Output

264

Output

2

Units
Required 1

Unit
kVA

Output
kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

3

0.05

1.5

4.16

1.65

4.58

—

—

0.9

2.5

—

—

S10N04A81N

3

0.05

—

—

—

—

1.27

3.54

—

—

0.71

1.98

S10N06A81N

3

0.10

3.0

8.33

3.3

9.17

—

—

1.8

5.0

—

—

S10N04A82N

Output

3

0.10

—

—

—

—

2.55

7.08

—

—

1.42

3.95

S10N06A82N

3

0.15

4.5

12.5

4.95

13.7

—

—

2.7

7.5

—

—

S10N04A83N

3

0.15

—

—

—

—

3.82

10.6

—

—

2.14

5.93

S10N06A83N

3

0.25

7.5

20.8

8.25

22.9

—

—

4.5

12.5

—

—

S10N04P26P

3

0.25

—

—

—

—

6.35

17.7

—

—

3.56

9.88

S10N06P26P

9

25

—

—

S10N04P51P

—

7.12

19.3

S10N06P51P

3

0.50

15

41.6

16.5

45.8

—

—

3

0.50

—

—

—

—

12.7

35.4

3

0.75

22.5

62.4

24.7

68.7

—

—

13.5

37.5

—

—

S10N04P76P

3

0.75

—

—

—

—

19

53.1

—

—

10.7

29.3

S10N06P76P

3

1

30

83.3

33

91.7

—

—

18

50

—

—

S10N04P01P

3

1

—

—

—

—

25.5

70.8

—

—

14.2

39.5

S10N06P01P

3

1.5

45

125

49.5

137

—

—

27

75

—

—

S10N04P16P

3

1.5

—

—

—

—

38.2

106

—

—

21.4

59.3

S10N06P16P

3

2

60

167

66

183

—

—

361

100

—

—

S10N04P02P

3

2

—

—

—

—

51

142

—

—

28.5

79.2

S10N06P02P

3

3

90

249.9

99

275.1

—

—

54

150

—

—

S10N04A03N

3

3

—

—

—

—

76.5

212.4

—

—

46.2

118.5

S10N06A03N

3

5

150

416

165

458

—

—

90

250

—

—

S10N04A05N

3

5

—

—

—

—

127

354

—

—

71.2

198

S10N06A05N

3

7.5

225

624

274

687

—

—

135

375

—

—

S10N04A07N

3

7.5

—

—

—

—

190

531

—

—

107

293

S10N06A07N

Connection Diagram 2

M

M

2

M

N

N

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-159

2.5
2
2
2
2
2

Transformers
Distribution Transformers

WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output

requires four-wire wye input.

Three-Phase Wye Connection 230 Volt Output Required, 60 Hz
Input Available Voltage
183

192

199

208

218

Output

Output

Output

Output

Output

Units
Required 1

Unit
kVA

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

3

0.05

—

—

0.83

2.08

—

—

1.65

4.58

1.66

4.17

S10N04A81N

2

3

0.05

0.62

1.56

—

—

0.54

1.35

—

—

—

—

S10N06A81N

2

3

0.10

—

—

1.66

4.17

—

—

3.3

9.17

3.32

8.35

S10N04A82N

3

0.10

1.25

3.12

—

—

1.08

2.71

—

—

—

—

S10N06A82N

2

3

0.15

—

—

2.49

6.25

—

—

4.95

13.7

4.98

12.5

S10N04A83N

3

0.15

1.87

4.69

—

—

1.62

4.06

—

—

—

—

S10N06A83N

2

3

0.25

—

—

4.15

10.4

—

—

8.2

22.9

8.3

20.9

S10N04P26P

3

0.25

3.11

7.81

—

—

2.70

6.77

—

—

—

—

S10N06P26P

2

3

0.50

—

—

8.3

20.8

—

—

16.5

45.8

16.6

41.7

S10N04P51P

2

3

0.50

6.22

15.6

—

—

5.39

13.5

—

—

—

—

S10N06P51P

3

0.75

—

—

12.4

31.2

—

—

24.7

68.8

24.9

62.6

S10N04P76P

2

3

0.75

9.33

23.4

—

—

8.09

20.3

—

—

—

—

S10N06P76P

3

1

—

—

16.6

41.7

—

—

33

91.7

33.2

83.5

S10N04P01P

2

3

1

12.5

31.2

—

—

10.8

27.1

—

—

—

—

S10N06P01P

3

1.5

—

—

24.9

62.5

—

—

49.5

137

49.8

125

S10N04P16P

2

3

1.5

18.7

46.9

—

—

16.2

40.6

—

—

—

—

S10N06P16P

2

3

2

—

—

33.2

83.3

—

—

66

183

66.4

167

S10N04P02P

3

2

24.9

62.5

—

—

21.6

54.2

—

—

—

—

S10N06P02P

2

3

3

—

—

49.8

125.1

—

—

99

275

99.6

250.5

S10N04A03N

3

3

37.5

93.6

—

—

32.4

81.3

—

—

—

—

S10N06A03N

2

3

5

—

—

83

208

—

—

165

458

166

417

S10N04A05N

2

3

5

62.2

156

—

—

53.9

135

—

—

—

—

S10N06A05N

3

7.5

—

—

124

312

—

—

247

688

249

626

S10N04A07N

2

3

7.5

93.3

234

—

—

80.9

203

—

—

—

—

S10N06A07N

2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2
2
2

Connection Diagram 2

N

N

S

M

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
V2-T2-160

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Q

Transformers
Distribution Transformers

2.5

WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output

requires four-wire wye input.

2

Three-Phase Wye Connection 230 Volt Output Required, 60 Hz

2

Input Available Voltage
242

245

253

Output

260

Output

265

Output

2

Units
Required 1

Unit
kVA

Output
kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

3

0.05

1.74

4.37

—

—

0.91

2.29

—

—

—

—

S10N04A81N

3

0.05

—

—

1.33

3.33

—

—

0.70

1.77

0.62

1.56

S10N06A81N

3

0.10

3.48

8.75

—

—

1.83

4.58

—

—

—

—

S10N04A82N

Output

3

0.10

—

—

2.65

6.67

—

—

1.41

3.54

1.25

3.12

S10N06A82N

3

0.15

5.23

13.1

—

—

2.74

6.87

—

—

—

—

S10N04A83N

3

0.15

—

—

3.98

10.0

—

—

2.12

5.31

1.87

4.69

S10N06A83N

3

0.25

8.71

21.9

—

—

4.56

11.5

—

—

—

—

S10N04P26P

3

0.25

—

—

6.63

16.7

—

—

3.52

8.85

3.11

7.81

S10N06P26P

3

0.50

17.4

43.7

—

—

9.31

22.9

—

—

—

—

S10N04P51P

3

0.50

—

—

13.3

33.3

—

—

7.05

17.7

6.22

15.6

S10N06P51P

3

0.75

26.1

65.6

—

—

13.7

34.4

—

—

—

—

S10N04P76P

3

0.75

—

—

19.9

50

—

—

10.6

26.6

9.33

23.4

S10N06P76P

3

1

34.8

87.5

—

—

18.3

45.8

—

—

—

—

S10N04P01P

3

1

—

—

26.5

66.7

—

—

14.1

35.4

12.5

31.2

S10N06P01P

3

1.5

52.3

131

—

—

27.4

68.7

—

—

—

—

S10N04P16P

3

1.5

—

—

39.8

100

—

—

21.2

53.1

18.7

46.9

S10N06P16P

3

2

69.7

175

—

—

36.6

91.6

—

—

—

—

S10N04P02P

3

2

—

—

53.1

133

—

—

28.2

70.8

24.9

62.5

S10N06P02P

3

3

104.4

262.5

—

—

54.9

137.4

—

—

—

—

S10N04A03N

3

3

—

—

79.5

200

—

—

42.3

106.2

37.5

93.6

S10N06A03N

3

5

174

437

—

—

91.3

229

—

—

—

—

S10N04A05N

3

5

—

—

133

333

—

—

70.5

177

62.2

156

S10N06A05N

—

—

—

S10N04A07N

266

93.3

234

S10N06A07N

3

7.5

261

656

—

—

137

344

3

7.5

—

—

199

500

—

—

Connection Diagram 2

Q

Q

2

R

106
R

S

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-161

2.5
2
2
2

Transformers
Distribution Transformers

WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output

requires four-wire wye input.

Three-Phase Wye Connection 240 Volt Output Required, 60 Hz
Input Available Voltage
190

200

208

218

Units
Required 1

Unit
kVA

Output

Output

Output

Output

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

3

0.05

—

—

0.86

2.08

—

—

0.86

2.08

1.73

4.17

S10N04A81N

2

3

0.05

0.65

1.65

—

—

1.27

3.05

—

—

—

—

S10N06A81N

2

3

0.10

—

—

1.73

4.17

—

—

1.73

4.17

3.46

8.34

S10N04A82N

3

0.10

1.3

3.12

—

—

2.55

6.12

—

—

—

—

S10N06A82N

2

3

0.15

—

—

2.59

6.25

—

—

2.59

6.25

5.20

12.5

S10N04A83N

3

0.15

1.95

4.69

—

—

3.82

9.16

—

—

—

—

S10N06A83N

2

3

0.25

—

—

4.32

10.4

—

—

4.32

10.4

8.66

20.9

S10N04P26P

3

0.25

3.25

7.81

—

—

6.3

15.1

—

—

—

—

S10N06P26P

2

3

0.50

—

—

8.65

20.8

—

—

8.65

20.8

17.3

41.7

S10N04P51P

2

3

0.50

6.5

15.6

—

—

12.7

30.4

—

—

—

—

S10N06P51P

3

0.75

—

—

13

31.2

—

—

13

31.2

26

62.6

S10N04P76P

2

3

0.75

9.75

23.4

—

—

19.2

46

—

—

—

—

S10N06P76P

3

1

—

—

17.3

41.7

—

—

17.3

41.7

34.6

83.4

S10N04P01P

2

3

1

13

31.2

—

—

25.5

61.2

—

—

—

—

S10N06P01P

3

1.5

—

—

25.9

62.5

—

—

25.9

62.5

52

125

S10N04P16P

2

3

1.5

19.5

46.9

—

—

38.2

91.6

—

—

—

—

S10N06P16P

2

3

2

—

—

34.6

83.3

—

—

34.6

83.3

69.3

167

S10N04P02P

3

2

26

62.5

—

—

51

122.4

—

—

—

—

S10N06P02P

2

3

3

—

—

51.9

125.1

—

—

51.9

125.1

103.8

250.2

S10N04A03N

3

3

39

93.6

—

—

76.5

183.6

—

—

—

—

S10N06A03N

2

3

5

—

—

86.5

208

—

—

86.5

208

173

417

S10N04A05N

2

3

5

65

156

—

—

127.2

305.2

—

—

—

—

S10N06A05N

3

7.5

—

—

130

312

—

—

130

312

260

626

S10N04A07N

3

7.5

97.5

234

—

—

192

460

—

—

—

—

S10N06A07N

2
2

2
2
2
2
2

Connection Diagram 2

N

N

M

R

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
V2-T2-162

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

228
Output

Q

Transformers
Distribution Transformers

2.5

WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output

requires four-wire wye input.

2

Three-Phase Wye Connection 240 Volt Output Required, 60 Hz

2

Input Available Voltage
252

256

264

Output

272

Output

277

Output

2

Units
Required 1

Unit
kVA

Output
kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

3

0.05

1.85

4.37

—

—

0.95

2.29

—

—

—

—

S10N04A81N

3

0.05

—

—

1.39

3.33

—

—

0.74

1.77

0.65

1.56

S10N06A81N

3

0.10

3.64

8.75

—

—

1.91

4.58

—

—

—

—

S10N04A82N

Output

3

0.10

—

—

2.77

6.67

—

—

1.47

3.54

1.3

3.12

S10N06A82N

3

0.15

5.46

13.1

—

—

2.86

6.87

—

—

—

—

S10N04A83N

3

0.15

—

—

4.16

10.0

—

—

2.21

5.31

1.95

4.69

S10N06A83N

3

0.25

9.09

21.9

—

—

4.76

11.5

—

—

—

—

S10N04P26P

3

0.25

—

—

6.93

16.7

—

—

3.68

8.85

3.25

7.81

S10N06P26P

3

0.50

18.2

43.7

—

—

9.53

22.9

—

—

—

—

S10N04P51P

3

0.50

—

—

13.9

33.3

—

—

7.36

17.7

6.5

15.6

S10N06P51P

3

0.75

27.3

65.6

—

—

14.3

34.4

—

—

—

—

S10N04P76P

3

0.75

—

—

20.8

50

—

—

11

26.6

9.75

23.4

S10N06P76P

3

1

36.4

87.5

—

—

19.1

45.8

—

—

—

—

S10N04P01P

3

1

—

—

27.7

66.7

—

—

14.7

35.4

13

31.2

S10N06P01P

3

1.5

54.6

131

—

—

28.6

68.7

—

—

—

—

S10N04P16P

3

1.5

—

—

41.6

100

—

—

22.1

53.1

19.5

46.9

S10N06P16P

3

2

72.8

175

—

—

38.1

91.7

—

—

—

—

S10N04P02P

3

2

—

—

55.4

133

—

—

29.5

70.8

26

62.5

S10N06P02P

3

3

109.2

262.5

—

—

57.3

137.4

—

—

—

—

S10N04A03N

3

3

—

—

83.1

200

—

—

44.1

106.2

39

93.6

S10N06A03N

3

5

182

437

—

—

95.3

229

—

—

—

—

S10N04A05N

3

5

—

—

139

333

—

—

73.6

177

65

156

S10N06A05N

3

7.5

273

656

—

—

143

344

—

—

—

—

S10N04A07N

3

7.5

—

—

208

500

—

—

110

266

97.5

234

S10N06A07N

Connection Diagram 2

Q

Q

2

R

R

S

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-163

2.5
2
2
2
2
2

Transformers
Distribution Transformers

WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output

requires four-wire wye input.

Three-Phase Wye Connection 460 Volt Output Required, 60 Hz
Input Available Voltage
406

418

432

Output

Output

Output

438
Output

Units
Required 1

Unit
kVA

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

3

0.05

—

—

1.66

2.08

—

—

3.22

4.04

S10N04A81N

2

3

0.05

1.25

1.57

—

—

2.49

3.12

—

—

S10N06A81N

2

3

0.10

—

—

3.31

4.15

—

—

6.62

8.31

S10N04A82N

3

0.10

2.49

3.12

—

—

4.97

6.24

—

—

S10N06A82N

3

0.15

—

—

4.97

6.24

—

—

9.94

12.48

S10N04A83N

3

0.15

3.73

4.68

—

—

7.46

9.36

—

—

S10N06A83N

3

0.25

—

—

8.28

10.39

—

—

16.6

20.84

S10N04P26P

3

0.25

6.22

7.81

—

—

12.4

15.56

—

—

S10N06P26P

2

3

0.50

—

—

16.6

20.84

—

—

33.2

41.67

S10N04P51P

2

3

0.50

12.5

15.69

—

—

24.69

31.25

—

—

S10N06P51P

3

0.75

—

—

24.8

31.12

—

—

49.6

62.25

S10N04P76P

2

3

0.75

18.7

23.47

—

—

37.3

46.82

—

—

S10N06P76P

3

1

—

—

33.1

41.54

—

—

66.2

83.09

S10N04P01P

2

3

1

24.9

31.25

—

—

49.7

62.38

—

—

S10N06P01P

3

1.5

—

—

49.7

62.38

—

—

99.4

124.75

S10N04P16P

2

3

1.5

37.3

46.94

—

—

74.6

93.63

—

—

S10N06P16P

2

3

2

—

—

66.3

83.22

—

—

133

166.93

S10N04P02P

3

2

49.7

62.38

—

—

99.5

124.88

—

—

S10N06P02P

2

3

3

—

—

99.3

124.64

—

—

198.6

249.27

S10N04A03N

3

3

74.6

93.63

—

—

149

187.01

—

—

S10N06A03N

2

3

5

—

—

166

208.35

—

—

322

404.16

S10N04A05N

2

3

5

125

156.89

—

—

249

312.53

—

—

S10N06A05N

3

7.5

—

—

248

311

—

—

496

622

S10N04A07N

3

7.5

187

235

—

—

373

468

—

—

S10N06A07N

2
2

2
2
2
2
2

Connection Diagram 2

R

R

Q

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
V2-T2-164

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Q

Transformers
Distribution Transformers

2.5

WARNING! Three-phase autotransformers should never be used to obtain four-wire output with three-wire input. Four-wire output

requires four-wire wye input.

2

Three-Phase Wye Connection 460 Volt Output Required, 60 Hz

2

Input Available Voltage
424

436

450

Output

2

Units
Required 1

Unit
kVA

Output
kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

3

0.05

—

1.7

2.1

—

—

—

S10N04A81N

3

0.05

1.3

1.56

—

—

2.6

3.13

S10N06A81N

3

0.10

—

—

3.5

4.2

—

—

S10N04A82N

3

0.10

2.6

3

0.15

Output

3

0.15

3
3

3.12

—

—

5.2

6.25

S10N06A82N

—

5.2

6.25

—

—

S10N04A83N

3.9

4.68

—

—

7.8

9.38

S10N06A83N

0.25

—

—

8.7

10.4

—

—

S10N04P26P

0.25

6.5

7.82

—

—

13

15.6

S10N06P26P

3

0.50

—

—

17.4

20.9

—

—

S10N04P51P

3

0.50

13

15.6

—

—

26

31.2

S10N06P51P

3

0.75

—

—

26

31.2

—

—

S10N04P76P

3

0.75

19.5

23.4

—

—

39

46.9

S10N06P76P

3

1

—

—

35

42

—

—

S10N04P01P

3

1

26

31.2

—

—

52

62.5

S10N06P01P

3

1.5

—

—

52

62.5

—

—

S10N04P16P

3

1.5

39

46.8

—

—

78

93.8

S10N06P16P

3

2

—

—

69

82.9

—

—

S10N04P02P

3

2

52

62.5

—

—

104

125

S10N06P02P

3

3

—

—

104

125

—

—

S10N04A03N

3

3

78

93.8

—

—

156

187.6

S10N06A03N

3

5

—

—

174

209.2

—

—

S10N04A05N

3

5

130

156.3

—

—

260

312.7

S10N06A05N

3

7.5

—

—

260

312

—

—

S10N04A07N

3

7.5

195

234

—

—

390

469

S10N06A07N

Connection Diagram 2

R

2

R

Q

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-165

2.5
2
2

Transformers
Distribution Transformers

Single-Phase Required, 60 Hz
Input Available Voltage/Output Voltage
200/240

230/277

346/380

Output

Output

Output

362/380
Output

Units
Required 1

Unit
kVA

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

1

0.25

1.25

5.2

1.44

5.2

1.98

5.2

3.95

10.4

S20N08P26P

2

1

0.50

2.50

10.4

2.88

10.4

3.95

10.4

7.90

20.8

S20N08P51P

2

1

0.75

3.75

15.6

4.32

15.6

5.93

15.6

11.9

31.2

S20N08P76P

1

1

5.00

20.8

5.76

20.8

7.90

20.8

15.8

41.6

S20N08P01P

2

1

1.5

7.50

31.2

8.64

31.2

11.9

31.2

23.8

62.5

S20N08P16P

1

2

10.0

41.6

11.5

41.6

15.8

41.6

31.6

83.3

S20N08P02P

2

1

3

15.0

62.5

17.3

62.5

23.8

62.5

47.5

125.0

S20N08A03N

2

1

5

25.0

104.0

28.8

104.0

39.5

104.0

79.0

208.0

S20N08A05N

1

7.5

37.5

156.0

43.2

156.0

59.3

156.0

118.6

312.0

S20N08A07N

Amps

Catalog Number

2

2
2

Connection Diagram 2

B

B

F

E

458/480

Single-Phase Required, 60 Hz
Input Available Voltage/Output Voltage

2

378/416

416/457

436/480

Output

Output

Output

Output

2

Units
Required 1

2

1

0.25

2.16

5.2

2.38

5.2

2.50

5.2

4.99

10.4

S20N08P26P

1

0.50

4.33

10.4

4.76

10.4

4.99

10.4

9.98

20.8

S20N08P51P

2

1

0.75

6.49

15.6

7.14

15.6

7.49

15.6

15.0

31.2

S20N08P76P

2

1

1

8.65

20.8

9.52

20.8

9.98

20.8

20.0

41.6

S20N08P01P

1

1.5

13.0

31.2

14.3

31.2

15.0

31.2

30.0

62.5

S20N08P16P

2

1

2

17.3

41.6

19.0

41.6

20.0

41.6

40.0

83.3

S20N08P02P

1

3

26.0

62.5

28.6

62.5

30.0

62.5

60.0

125.0

S20N08A03N

2

1

5

43.3

104.0

47.6

104.0

49.9

104.0

99.8

208.0

S20N08A05N

1

7.5

64.9

156.0

71.4

156.0

74.9

156.0

149.8

312.0

S20N08A07N

2

Connection Diagram 2

Unit
kVA

kVA

Amps

F

kVA

F

Amps

kVA

Amps

F

2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2

2
2
2
2
2
2
2
2
V2-T2-166

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

kVA

E

Transformers
Distribution Transformers

2.5

Single-Phase Required, 60 Hz

2

Input Available Voltage/Output Voltage
277/230

480/456

504/480

Output

Output

Output

2

528/480
Output

Units
Required 1

Unit
kVA

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

1

0.25

1.44

6.26

5.23

11.4

5.47

11.4

2.75

5.72

S20N08P26P

1

0.50

2.88

12.5

10.4

22.8

10.9

22.8

5.49

11.4

S20N08P51P

1

0.75

4.33

18.8

15.7

34.2

16.4

34.2

8.24

17.2

S20N08P76P

1

1

5.76

25.0

20.9

45.6

21.8

45.6

11.0

22.9

S20N08P01P

1

1.5

8.64

37.6

31.3

68.4

32.8

68.4

16.5

34.3

S20N08P16P

1

2

11.5

50.1

41.8

91.2

43.7

91.2

22.0

45.8

S20N08P02P

1

3

17.3

75.3

62.7

136.0

65.2

136.0

33.0

68.8

S20N08A03N

1

5

28.8

125.3

104.5

227.0

108.0

227.0

54.9

114.4

S20N08A05N

1

7.5

43.2

187.9

156.8

341.0

163.0

341.0

82.4

171.6

S20N08A07N

Connection Diagram 2

B

E

E

F

2
2
2
2
2
2
2

Notes
1 Additional wiring trough may be required.
2 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2
2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-167

2.5
2
2

Transformers
Distribution Transformers

Three-Phase Required, 60 Hz
Input Available Voltage/Output Voltage
362/380

346/416

430/473

400/480

Unit
kVA

Output

Output

Output

Output

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number

0.25

6.52

10.4

3.75

5.2

4.26

5.2

4.33

5.2

4.33

5.2

S20N08P26P

2

0.50

13.0

20.8

7.50

10.4

8.52

10.4

8.65

10.4

8.65

10.4

S20N08P51P

2

0.75

19.6

31.2

11.2

15.6

12.8

15.6

13.0

15.6

13.0

15.6

S20N08P76P

1

26.1

41.6

15.0

20.8

17.0

20.8

17.3

20.8

17.3

20.8

S20N08P01P

2

1.5

39.1

62.4

22.5

31.2

25.5

31.2

26.0

31.2

26.0

31.2

S20N08P16P

2

52.2

83.2

30.0

41.6

34.1

41.6

34.6

41.6

34.6

41.6

S20N08P02P

2

3

78.4

125.0

45.0

62.5

51.2

62.5

52.0

62.5

52.0

62.5

S20N08A03N

2

5

130.4

208.0

75.1

104.0

85.2

104.0

86.6

104.0

86.6

104.0

S20N08A05N

7.5

195.6

312.0

112.6

156.0

127.8

156.0

129.9

156.0

129.9

156.0

S20N08A07N

Connection Diagram 1

I

N

K

N

K

Units Required 2

2

3

2

3

2

2

2

436/480
Output

2
2
2

Three-Phase Required, 60 Hz
Input Available Voltage/Output Voltage
460/483

457/380

504/480

528/480

Unit
kVA

Output

Output

Output

Output

0.25

8.7

10.4

4.12

6.25

9.08

10.9

2

0.50

17.4

20.8

8.23

12.5

18.2

21.8

2

0.75

26.1

31.2

12.3

18.8

27.2

32.8

1

34.8

41.6

16.5

25.0

36.3

2

1.5

52.2

62.4

24.7

37.5

2

69.6

83.2

32.9

2

3

104.6

125.0

5

174.0

2

7.5

261.0

2

Connection Diagram 1

I

N

I

K

Units Required 2

2

3

2

2

2

2
2
2
2

kVA

Amps

Catalog Number

4.76

5.72

S20N08P26P

9.51

11.4

S20N08P51P

14.3

17.2

S20N08P76P

43.7

19.0

22.9

S20N08P01P

54.5

65.5

28.5

34.3

S20N08P16P

50.0

72.6

87.4

38.0

45.8

S20N08P02P

49.5

75.2

109.7

131.3

57.2

68.8

S20N08A03N

208.0

82.3

125.1

181.6

218.4

95.1

114.4

S20N08A05N

312.0

123.5

187.6

272.4

327.6

142.7

171.6

S20N08A07N

Amps

kVA

Amps

kVA

Amps

Notes
1 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
2 Additional wiring trough may be required.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
V2-T2-168

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

kVA

2.5

Transformers
Distribution Transformers

Three-Phase Open Delta Connection 480 Volt Output Required, 60 Hz

2

Input Available Voltage
600

575

575

Output

Output

Output

2

Units Required 1

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number 2

2

4.3

5.1

—

—

—

—

S20N11P51P

2

—

—

—

—

4.1

4.9

S60G11P51P

2

6.5

7.8

—

—

—

—

S20N11P76P

2

—

—

—

—

6.2

7.4

S60G11P76P

2

8.6

10.3

—

—

—

—

S20N11P01P

2

—

—

—

—

8.3

9.9

S60G11P01P

2

13.0

15.6

—

—

—

—

S20N11P16P

2

—

—

—

—

12.4

14.9

S60G11P16P

2

17.2

20.6

—

—

—

—

S20N11P02P

2

—

—

—

—

16.5

19.8

S60G11P02P

2

25.8

31

—

—

—

—

S20N11S03N

2

—

—

—

—

24.8

29.8

S60G11P03P

2

43.2

51.9

—

—

—

—

S20N11S05N

2

—

—

—

—

41

49.3

S60G11S05N

2

65

78.1

—

—

—

—

S20N11S07N

2

—

—

—

—

62

74.5

S60G11S07N

2

86

103.4

—

—

—

—

S20N11S10N

2

—

—

83

99.8

—

—

S60G11S10N

2

130

156.3

—

—

—

—

S20N11S15N

2

—

—

124

149.1

—

—

S60N11S15N

2
2
2
2
2
2
2
2
2
2
2

2

216

259.8

—

—

—

—

T20P11S25EE

2

—

—

207

248.9

—

—

S60J11S25N

2

324

389.7

—

—

—

—

T20P11S37EE

2

432

519.6

—

—

—

—

T20P11S50EE

Connection Diagram 3

I

J

2

T

2
2
2
2

Notes
1 Additional wiring trough may be required.
2 On transformers supplied with standard taps, taps must be placed at nominal settings.
3 Refer to Page V2-T2-172 for buck-boost wiring diagrams.

2
2

Autotransformers can be used only where local electric codes permit and isolation of the two circuits is not required.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage

2

Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage

2

Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-169

2.5
2

Distribution Transformers

Single-Phase 480 Volt Output Required, 60 Hz
Input Available Voltage

2
2

Transformers

600

575

Output

Output

575
Output

Units Required 1

kVA

Amps

kVA

Amps

kVA

Amps

Catalog Number 2

1

2.5

5.2

—

—

—

—

S20N11P51P

2

1

—

—

—

—

2.4

5

S60G11P51P

2

1

3.7

7.7

—

—

—

—

S20N11P76P

1

—

—

—

—

3.6

7.5

S60G11P76P

2

1

5.0

10.4

—

—

—

—

S20N11P01P

1

—

—

—

—

4.8

10

S60G11P01P

2

1

7.5

15.6

—

—

—

—

S20N11P16P

2

1

—

—

—

—

7.2

15

S60G11P16P

1

10

20.8

—

—

—

—

S20N11P02P

2

1

—

—

—

—

9.6

20

S60G11P02P

1

15

31.2

—

—

—

—

S20N11S03N

2

1

—

—

—

—

14.3

29.7

S60G11P03P

1

25

52

—

—

—

—

S20N11S05N

2

1

—

—

—

—

24

50

S60G11S05N

2

1

37.5

78.1

—

—

—

—

S20N11S07N

1

—

—

—

—

36

75

S60G11S07N

2

1

50

104.1

—

—

—

—

S20N11S10N

1

—

—

43

100

—

—

S60G11S10N

2

1

75

156.2

—

—

—

—

S20N11S15N

1

—

—

72

150

—

—

S60N11S15N

1

125

260.4

—

—

—

—

T20P11S25EE

1

—

—

120

250

—

—

S60J11S25N

1

187

389.6

—

—

—

—

T20P11S37EE

1

250

520.8

—

—

—

—

T20P11S50EE

Connection Diagram 3

E

2
2
2
2
2
2
2
2
2

H

Notes
1 Additional wiring trough may be required.
2 On transformers supplied with standard taps, taps must be placed at nominal settings.
3 Refer to Page V2-T2-172 for buck-boost wiring diagrams.
Autotransformers can be used only where local electric codes permit and isolation of the two circuits is not required.
Rated Output Voltage
Output voltage for lower input voltage can be found by: ------------------------------------------------------- x Input Actual Voltage = Output New Voltage.
Rated Input Voltage
Actual Input Voltage
Output kVA available at reduced input voltage can be found by: ----------------------------------------------------- x Output kVA = New kVA Rating.
Rated Input Voltage
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
V2-T2-170

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

U

2.5

Transformers
Distribution Transformers

Accessories
Please refer to Section 2.7 Page V2-T2-191.

2

Technical Data and Specifications

2

Frequency
Eaton buck-boost
transformers are designed
for 60 Hz operation.

Enclosures
Eaton encapsulated buckboost transformers use a
NEMA 3R rated enclosure.

Overload Capability
Short-term overload is
designed into transformers as
required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour, and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250
for additional limitations.

Winding Terminations
Primary and secondary
windings are terminated in
the wiring compartment.
Encapsulated units have
copper leads or stabs brought
out for connections. Lugs
are not supplied with
these transformers. Eaton
recommends that external
cables be rated 90°C
(sized at 75°C ampacity) for
encapsulated designs.

Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.
Insulation System and
Temperature Rise
Industry standards classify
insulation systems and rise as
shown below:
Insulation System
Classification

Ambient

+
Winding
Rise

+
Hot
Spot

=
Temp.
Class

40°C

55°C

10°C

105°C

40°C

80°C

30°C

150°C

25°C

135°C

20°C

180°C

40°C

115°C

30°C

185°C

40°C

150°C

30°C

220°C

The design life of transformers
having different insulation
systems is the same—the
lower-temperature systems
are designed for the same life
as the higher-temperature
systems.

Series-Multiple Windings
Series-multiple windings
consist of two similar coils
in each winding that can be
connected in series or parallel
(multiple). Transformers with
series-multiple windings are
designated with an “x” or
“/” between the voltage
ratings, such as voltages of
“120/240” or “240 x 480.”
If the series-multiple winding
is designated by an “x,” the
winding can be connected
only for a series or parallel.
With the “/” designation,
a mid-point also becomes
available in addition to the
series or parallel connection.
As an example, a 120 x 240
winding can be connected for
either 120 (parallel) or 240
(series), but a 120/240
winding can be connected for
120 (parallel), 240 (series) or
240 with a 120 mid-point.

Sound Levels
All Eaton 600 volt class
general-purpose dry-type
distribution transformers are
designed to meet NEMA
ST-20 sound levels listed
here. These are the sound
levels measured in a
soundproof environment.
Actual sound levels
measured at an installation
will likely be higher due to
electrical connections and
environmental conditions.
Lower sound levels are
available and should be
specified when the
transformer is going to be
installed in an area where
sound may be a concern.

Note: When installation is to be
made on a grounded system,
consideration must be given to
the resulting voltage. Thus, on a
208 grounded wye/120 system,
the voltage can be boosted to 240
volts but the voltage to ground
will be 139 volts. If 240/120 volts
with a mid-point ground is
needed, a standard two-winding
transformer must be used.

The following formulas can
be used to calculate specific
requirements.
For single-phase:
Load Voltage x
Line AmperesLOAD kVA = Full
-------------------------------------------1000

2
2
2
2
2
2
2
2
2

For three-phase:

For additional information,
please refer to Section 2.7
Page V2-T2-195.

2

Line Load Voltage x 1.73 x
Full Load Amperes LOAD kVA = ----------------------------------------------------------------1000

2
2
2

Average Sound Levels

2

NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

Encapsulated
(up to 1.2 kV)

2
2

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

2

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

50.01 to 75.00

50

53

55

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

500.01 to 700.00

62

65

61

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-171

2.5

Transformers
Distribution Transformers

2

Wiring Diagrams

2

Buck-Boost Transformers Wiring Diagrams
Diagram A

Diagram B

2
2
2
2

X4

X1

X2

H4

H3

H4

H3

H4

H3

H2

H1

H2

H1

H2

H1

X1

H3

H2

H1

X4

H2

X3

X4

X1

X2

X4

X4

X3

X2

X2

X1

H1 H1

H2

X4 X3 X2 X1

H4 H3 H2 H1

H1 H2 H3 H4

X3

X3
X2

X1
H4

X2
H3

H4

H3

H2

H1

H2

H1

H2

H1

H2

H1

Low Voltage

X1
X4

X2
H3

Neutral

Diagram P 1

X4

X2

X3

H4

H3

H4

H3

H4

H3

H2

H1

H2

H1

H2

H1

X1

X3

X3

X4

H4

H3

H4

H3

X1
H4

X2
H3

X1
H4

X2
H3

X1
H4

X2
H3

H2

H1

H2

H1

H2

H1

H2

H1

H2

X4
X3

H3

X2
X1

H1
H2

High Voltage

X3

X4

X3

X4

X1

X2

X1

X2

X1

X2

H3
H4

H1
H2

H3
H4

H1
H2

H3 H1
H4 H2

Low Voltage

H3
H4

X1

X3

X2
X1

H1
H2

High Voltage

X4
X3

H3
H4

X1

X3

X1

X3

X2

X4

X2

X4

X2

H3

H1

H3

H1

H3 H1

H4

H2

H4

H2

X4

H4 H2

Low Voltage

Neutral

Neutral

Diagram U
High Voltage

High Voltage

X4
X3

H1

Neutral

Diagram R 1

X4

Low Voltage
X2

High Voltage

Neutral

Diagram T

Diagram S 1

2

X4

X4

X3

Neutral

High Voltage

H4

X3

X3
X2

X4

X1

2

X1
X4

X4

High Voltage

X3

X1

X3
X2

X3

Diagram Q 1

X1

2

H1 H2 H3 H4

Low Voltage

Low Voltage

Low Voltage

2

H4 H3 H2 H1

High Voltage

X4

X1
H4

X2

X4 X3 X2 X1

Diagram O 1

X2
H3

X4

X1 X2 X3 X4

High Voltage

X4

H1 H2 H3 H4

Low Voltage

X1 X2 X3 X4

X1
H4

X2

X1

Diagram L

X1

2

X3

X2

Low Voltage

Diagram N 1
X3

X4

X2

H4 H3 H2 H1

H1

High Voltage
X4

X4

X1

Low Voltage

Diagram M 1

H1

X3

High Voltage

X3

H2

High Voltage

Low Voltage

X1

X3

H3

Low Voltage

H2

H1

Low Voltage

2

H4

Diagram K

H2

2

H1

X4

Diagram I

High Voltage

2

H2

X2 X3

High Voltage

Diagram J

2

2

H3

X1

Low Voltage

X3

H3

2

2

X2

Diagram H

2

2

X1

High Voltage

2

High Voltage

X4

Low Voltage

2

High Voltage

X3

H4

Diagram G

H4

X2

Diagram F

X4

H4

X2

X4

X1

High Voltage

X2 X3

X1

X3

Low Voltage

High Voltage

2

X4

Diagram E
Low Voltage

2

2

X2 X3

Low Voltage

2

2

X1

Diagram D

2

Low Voltage

High Voltage

X3

2

2

Diagram C

High Voltage

X3

X4

X4

X3

X1

X2

X2

X1

X3

X4

X1

X2

H1
H2

Neutral

H4

H1

H1

H4

Low Voltage

H1

H4

Low Voltage

Note
1

WARNING! If input is three-wire, “neutral” connection must be isolated and insulated! When used to supply a three-phase, four-wire load, the source must be three-phase, four-wire wye.

V2-T2-172

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.5

Transformers
Distribution Transformers

Contents
Description

Page

Motor Drive Isolation Transformers . . . . . . . . . . . .
Mini–Power Centers . . . . . . . . . . . . . . . . . . . . . . .
Totally Enclosed Non-Ventilated Transformers. . . .
Class I, Division 2, Hazardous Location Transformers
Open-Type Core and Coil Assembly Transformers
Marine Duty Transformers. . . . . . . . . . . . . . . . . . .
Buck-Boost and Low Voltage Lighting Transformers
Medium Voltage Distribution Transformers
Features, Benefits and Functions . . . . . . . . . . .
Standards and Certifications. . . . . . . . . . . . . . .
Product Description . . . . . . . . . . . . . . . . . . . . .

V2-T2-111
V2-T2-119
V2-T2-124
V2-T2-127
V2-T2-130
V2-T2-133
V2-T2-144
V2-T2-174
V2-T2-174
V2-T2-175

2
2
2
2
2
2
2
2
2
2
2

Medium Voltage Distribution Transformers
Product Description
Note: The following pages
provide listings for most standard
transformer ratings and catalog
numbers. For other ratings or
catalog numbers not shown,
or for special enclosure types
(including stainless steel), refer
to Eaton.

Single- and Three-Phase
● Ventilated, NEMA 3R
enclosure standard
● Suitable for indoor or
outdoor applications
● Upright mounting only
● 220ºC insulation system
● 150ºC rise standard;
115°C or 80°C rise optional
● Available in single-phase
ratings 15–333 kVA
● Available in single-phase
ratings 25–167 kVA; in
three-phase ratings
15–1500 kVA

Application Description
U.S. DOE 10 CFR Part 431
compliant energy-efficient
transformers are specifically
designed to meet the energy
efficiency standards set
forth in U.S. DOE 10 CFR Part
431. Compliant transformers
are optimized to offer
maximum efficiency at 50%
of nameplate rating.

Transformers that are
currently specifically excluded
from the scope of DOE 10
CFR Part 431 include:
●

●

●

●

●
●

●

●
●

●
●
●

●

●
●

Liquid-filled transformers
below 10 kVA
Dry-type transformers
below 15 kVA
AC and DC drives
transformers
Rectifier transformers
designed for high
harmonics
Autotransformers
Non-distribution
transformers, such as
UPS transformers
Special impedance or
regulation transformers
Regulating transformers
Sealed and non-ventilated
transformers
Machine tool transformers
Welding transformers
Transformers with tap
ranges greater than 15%
Transformers with a
frequency other than 60 Hz
Grounding transformers
Testing transformers

DOE 10 CFR Part 431
Efficiency Levels
Tables of Energy Efficiency
Dry-Type Distribution Transformers—
20–45 kV BIL
Single-Phase

Three-Phase

kVA Efficiency

kVA

Efficiency

15

98.10

15

97.50

25

98.33

30

97.90

37.5 98.49

45

98.10

50

98.60

75

98.33

75

98.73

112.5

98.49

100

98.82

150

98.60

167

98.96

225

98.73

250

99.07

300

98.82

333

99.14

500

98.96

—

—

750

99.07

—

—

1000

99.14

—

—

1500

99.22

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-173

2.5

Transformers
Distribution Transformers

2

Features, Benefits
and Functions

2

●

2

●

2
2
2
2

●

●

60 Hz operation (except
as noted)
Short-term overload
capability as required
by ANSI
Meet NEMA ST-20
sound levels
Meet federal energy
efficiency requirements
for dry-type transformers
effective as of
January 1, 2010

2
2
2

Standards and Certifications
●

UL listed

Industry Standards
All Eaton dry-type distribution
and control transformers are
built and tested in accordance
with applicable NEMA, ANSI
and IEEE Standards.
Seismically Qualified
Eaton manufactured dry-type
distribution transformers are
seismically qualified and
exceed requirements of the
International Building Code
(IBC) and California Code
Title 24.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-174

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Product Description

2

Single-Phase—2010 Energy-Efficient

2
2

2400 Volts to 120/240 Volts—Aluminum Windings
Full Capacity Taps
kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

25

2 at +2.5%

2 at –2.5%

150

NH6

—

—

Included

T42D11S25E3R

37.5

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

T42D11S37E3R

50

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

T42D11S50E3R

75

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

T42D11S75E3R

100

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

T42D11S99E3R

167

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

T42D11S67E3R

25

2 at +2.5%

2 at –2.5%

115

NH6

—

—

Included

T42D11F25E3R

37.5

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T42D11F37E3R

50

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T42D11F50E3R

75

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T42D11F75E3R

100

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

T42D11F99E3R

167

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

T42D11F67E3R

25

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T42D11B25E3R

37.5

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T42D11B37E3R

50

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T42D11B50E3R

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

T42D11B75E3R

100

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

T42D11B99E3R

167

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

T42D11B67E3R

2
2
2
2
2
2
2
2
2
2
2
2
2

4160 Volts to 120/240 Volts—Aluminum Windings
Full Capacity Taps
kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

25

2 at +2.5%

2 at –2.5%

150

NH6

—

—

Included

T46D11S25E3R

37.5

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

T46D11S37E3R

50

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

T46D11S50E3R

75

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

T46D11S75E3R

100

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

T46D11S99E3R

167

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

T46D11S67E3R

25

2 at +2.5%

2 at –2.5%

115

NH6

—

—

Included

T46D11F25E3R

37.5

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T46D11F37E3R

50

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T46D11F50E3R

2

Catalog Number

75

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T46D11F75E3R

100

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

T46D11F99E3R

167

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

T46D11F67E3R

25

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T46D11B25E3R

37.5

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T46D11B37E3R

50

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T46D11B50E3R

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

T46D11B75E3R

100

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

T46D11B99E3R

167

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

T46D11B67E3R

2
2
2
2
2
2
2
2
2
2

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-175

2.5
2

Transformers
Distribution Transformers

Single-Phase—2010 Energy-Efficient

2

2400 Volts to 120/240 Volts—Copper Windings

2

kVA

FCAN

25

2 at +2.5%

2 at –2.5%

37.5

2 at +2.5%

2 at –2.5%

2

50

2 at +2.5%

2 at –2.5%

2

75

2 at +2.5%

100

Full Capacity Taps

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

150

NH6

—

—

Included

T42D11S25CUE3R

150

NH3

—

—

Included

T42D11S37CUE3R

150

NH3

—

—

Included

T42D11S50CUE3R

2 at –2.5%

150

NH3

—

—

Included

T42D11S75CUE3R

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

T42D11S99CUE3R

2

167

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

T42D11S67CUE3R

25

2 at +2.5%

2 at –2.5%

115

NH6

—

—

Included

T42D11F25CUE3R

2

37.5

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T42D11F37CUE3R

2

50

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T42D11F50CUE3R

75

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T42D11F75CUE3R

2

100

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

T42D11F99CUE3R

167

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

T42D11F67CUE3R

2

25

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T42D11B25CUE3R

37.5

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T42D11B37CUE3R

2

50

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T42D11B50CUE3R

2

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

T42D11B75CUE3R

100

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

T42D11B99CUE3R

167

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

T42D11B67CUE3R

2

2

FCBN

ºC Temp.
Rise

2

4160 Volts to 120/240 Volts—Copper Windings

2

kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

25

2 at +2.5%

2 at –2.5%

150

NH6

—

—

Included

T46D11S25CUE3R

2

37.5

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

T46D11S37CUE3R

50

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

T46D11S50CUE3R

2

75

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

T46D11S75CUE3R

100

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

T46D11S99CUE3R

2

167

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

T46D11S67CUE3R

25

2 at +2.5%

2 at –2.5%

115

NH6

—

—

Included

T46D11F25CUE3R

2

37.5

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T46D11F37CUE3R

2

50

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T46D11F50CUE3R

75

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

T46D11F75CUE3R

2

100

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

T46D11F99CUE3R

167

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

T46D11F67CUE3R

2

25

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T46D11B25CUE3R

37.5

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T46D11B37CUE3R

2

50

2 at +2.5%

2 at –2.5%

80

NH3

—

—

Included

T46D11B50CUE3R

2

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

T46D11B75CUE3R

100

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

T46D11B99CUE3R

167

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

T46D11B67CUE3R

2
2

Full Capacity Taps

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
V2-T2-176

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Three-Phase—2010 Energy-Efficient

2
2

2400 Delta Volts to 480Y/277 Volts—Copper Windings
Full Capacity Taps
kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

45

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

V42D47T45CUE3R

75

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V42D47T75CUE3R

112.5

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V42D47T12CUE3R

150

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D47T49CUE3R

225

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D47T22CUE3R

300

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D47T33CUE3R

500

2 at +2.5%

2 at –2.5%

150

NJ2

—

—

Included

V42D47T55CUE3R

750

2 at +2.5%

2 at –2.5%

150

NJ3

—

—

Included

V42D47T77CUE3R

45

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

V42D47F45CUE3R

75

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V42D47F75CUE3R

112.5

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V42D47F12CUE3R

150

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D47F49CUE3R

225

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D47F22CUE3R

300

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D47F33CUE3R

500

2 at +2.5%

2 at –2.5%

115

NJ2

—

—

Included

V42D47F55CUE3R

750

2 at +2.5%

2 at –2.5%

115

NJ3

—

—

Included

V42D47F77CUE3R

45

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V42D47B45CUE3R

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V42D47B75CUE3R

112.5

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D47B12CUE3R

150

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D47B49CUE3R

225

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D47B22CUE3R

300

2 at +2.5%

2 at –2.5%

80

NJ2

—

—

Included

V42D47B33CUE3R

500

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V42D47B55CUE3R

750

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V42D47B77CUE3R

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-177

2.5
2

Transformers
Distribution Transformers

Three-Phase—2010 Energy-Efficient

2

4160 Delta Volts to 480Y/277 Volts—Copper Windings

2

kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

45

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

V46D47T45CUE3R

75

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V46D47T75CUE3R

2

112.5

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V46D47T12CUE3R

2

150

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D47T49CUE3R

225

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D47T22CUE3R

2

300

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D47T33CUE3R

500

2 at +2.5%

2 at –2.5%

150

NJ2

—

—

Included

V46D47T55CUE3R

2

750

2 at +2.5%

2 at –2.5%

150

NJ3

—

—

Included

V46D47T77CUE3R

2

45

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

V46D47F45CUE3R

75

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V46D47F75CUE3R

2

112.5

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V46D47F12CUE3R

150

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D47F49CUE3R

2

225

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D47F22CUE3R

300

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D47F33CUE3R

2

500

2 at +2.5%

2 at –2.5%

115

NJ2

—

—

Included

V46D47F55CUE3R

2

750

2 at +2.5%

2 at –2.5%

115

NJ3

—

—

Included

V46D47F77CUE3R

45

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V46D47B45CUE3R

2

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V46D47B75CUE3R

112.5

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D47B12CUE3R

2

150

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D47B49CUE3R

2

Full Capacity Taps

225

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D47B22CUE3R

2

300

2 at +2.5%

2 at –2.5%

80

NJ2

—

—

Included

V46D47B33CUE3R

2

500

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V46D47B55CUE3R

750

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V46D47B77CUE3R

2
2

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
V2-T2-178

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Three-Phase—2010 Energy-Efficient

2
2

2400 Delta Volts to 208Y/120 Volts—Copper Windings
Full Capacity Taps
kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

2

Catalog Number

45

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

V42D28T45CUE3R

75

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V42D28T75CUE3R

112.5

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V42D28T12CUE3R

150

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D28T49CUE3R

225

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D28T22CUE3R

300

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D28T33CUE3R

500

2 at +2.5%

2 at –2.5%

150

NJ2

—

—

Included

V42D28T55CUE3R

750

2 at +2.5%

2 at –2.5%

150

NJ3

—

—

Included

V42D28T77CUE3R

45

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

V42D28F45CUE3R

75

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V42D28F75CUE3R

112.5

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V42D28F12CUE3R

150

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D28F49CUE3R

225

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D28F22CUE3R

300

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D28F33CUE3R

500

2 at +2.5%

2 at –2.5%

115

NJ2

—

—

Included

V42D28F55CUE3R

750

2 at +2.5%

2 at –2.5%

115

NJ3

—

—

Included

V42D28F77CUE3R

45

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V42D28B45CUE3R

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V42D28B75CUE3R

112.5

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D28B12CUE3R

150

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D28B49CUE3R

225

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D28B22CUE3R

300

2 at +2.5%

2 at –2.5%

80

NJ2

—

—

Included

V42D28B33CUE3R

500

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V42D28B55CUE3R

750

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V42D28B77CUE3R

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-179

2.5
2

Transformers
Distribution Transformers

Three-Phase—2010 Energy-Efficient

2

4160 Delta Volts to 208Y/120 Volts—Copper Windings

2

kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

45

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

V46D28T45CUE3R

75

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V46D28T75CUE3R

2

112.5

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V46D28T12CUE3R

2

150

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D28T49CUE3R

225

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D28T22CUE3R

2

300

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D28T33CUE3R

500

2 at +2.5%

2 at –2.5%

150

NJ2

—

—

Included

V46D28T55CUE3R

2

750

2 at +2.5%

2 at –2.5%

150

NJ3

—

—

Included

V46D28T77CUE3R

2

45

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

V46D28F45CUE3R

75

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V46D28F75CUE3R

2

112.5

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V46D28F12CUE3R

150

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D28F49CUE3R

2

225

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D28F22CUE3R

300

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D28F33CUE3R

2

500

2 at +2.5%

2 at –2.5%

115

NJ2

—

—

Included

V46D28F55CUE3R

2

750

2 at +2.5%

2 at –2.5%

115

NJ3

—

—

Included

V46D28F77CUE3R

45

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V46D28B45CUE3R

2

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V46D28B75CUE3R

112.5

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D28B12CUE3R

2

150

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D28B49CUE3R
V46D28B22CUE3R

2

Full Capacity Taps

225

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

2

300

2 at +2.5%

2 at –2.5%

80

NJ2

—

—

Included

V46D28B33CUE3R

2

500

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V46D28B55CUE3R

750

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V46D28B77CUE3R

2
2

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
V2-T2-180

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Three-Phase—2010 Energy-Efficient

2
2

2400 Delta Volts to 480Y/277 Volts—Aluminum Windings
Full Capacity Taps
kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

45

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

V42D47T45E3R

75

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V42D47T75E3R

112.5

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V42D47T12E3R

150

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D47T49E3R

225

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D47T22E3R

300

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D47T33E3R

500

2 at +2.5%

2 at –2.5%

150

NJ2

—

—

Included

V42D47T55E3R

750

2 at +2.5%

2 at –2.5%

150

NJ3

—

—

Included

V42D47T77E3R

45

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

V42D47F45E3R

75

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V42D47F75E3R

112.5

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V42D47F12E3R

150

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D47F49E3R

225

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D47F22E3R

300

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D47F33E3R

500

2 at +2.5%

2 at –2.5%

115

NJ2

—

—

Included

V42D47F55E3R

750

2 at +2.5%

2 at –2.5%

115

NJ3

—

—

Included

V42D47F77E3R

45

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V42D47B45E3R

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V42D47B75E3R

112.5

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D47B12E3R

150

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D47B49E3R

225

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D47B22E3R

300

2 at +2.5%

2 at –2.5%

80

NJ2

—

—

Included

V42D47B33E3R

500

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V42D47B55E3R

750

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V42D47B77E3R

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-181

2.5
2

Transformers
Distribution Transformers

Three-Phase—2010 Energy-Efficient

2

4160 Delta Volts to 480Y/277 Volts—Aluminum Windings

2

kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

45

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

V46D47T45E3R

75

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V46D47T75E3R

2

112.5

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V46D47T12E3R

2

150

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D47T49E3R

225

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D47T22E3R

2

300

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D47T33E3R

500

2 at +2.5%

2 at –2.5%

150

NJ2

—

—

Included

V46D47T55E3R

2

750

2 at +2.5%

2 at –2.5%

150

NJ3

—

—

Included

V46D47T77E3R

2

45

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

V46D47F45E3R

75

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V46D47F75E3R

2

112.5

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V46D47F12E3R

150

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D47F49E3R

2

225

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D47F22E3R

300

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D47F33E3R

2

500

2 at +2.5%

2 at –2.5%

115

NJ2

—

—

Included

V46D47F55E3R

2

750

2 at +2.5%

2 at –2.5%

115

NJ3

—

—

Included

V46D47F77E3R

45

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V46D47B45E3R

2

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V46D47B75E3R

112.5

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D47B12E3R

2

150

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D47B49E3R

225

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D47B22E3R

300

2 at +2.5%

2 at –2.5%

80

NJ2

—

—

Included

V46D47B33E3R

500

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V46D47B55E3R

750

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V46D47B77E3R

2

2
2
2
2

Full Capacity Taps

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
V2-T2-182

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Distribution Transformers

2.5

Three-Phase—2010 Energy-Efficient

2
2

2400 Delta Volts to 208Y/120 Volts—Aluminum Windings
Full Capacity Taps
kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

45

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

V42D28T45E3R

75

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V42D28T75E3R

112.5

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V42D28T12E3R

150

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D28T49E3R

225

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D28T22E3R

300

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V42D28T33E3R

500

2 at +2.5%

2 at –2.5%

150

NJ2

—

—

Included

V42D28T55E3R

750

2 at +2.5%

2 at –2.5%

150

NJ3

—

—

Included

V42D28T77E3R

45

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

V42D28F45E3R

75

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V42D28F75E3R

112.5

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V42D28F12E3R

150

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D28F49E3R

225

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D28F22E3R

300

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V42D28F33E3R

500

2 at +2.5%

2 at –2.5%

115

NJ2

—

—

Included

V42D28F55E3R

750

2 at +2.5%

2 at –2.5%

115

NJ3

—

—

Included

V42D28F77E3R

45

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V42D28B45E3R

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V42D28B75E3R

112.5

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D28B12E3R

150

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D28B49E3R

225

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V42D28B22E3R

300

2 at +2.5%

2 at –2.5%

80

NJ2

—

—

Included

V42D28B33E3R

500

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V42D28B55E3R

750

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V42D28B77E3R

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-183

2.5
2

Transformers
Distribution Transformers

Three-Phase—2010 Energy-Efficient

2

4160 Delta Volts to 208Y/120 Volts—Aluminum Windings

2

kVA

FCAN

FCBN

ºC Temp.
Rise

Frame

Wiring Diagram
Number

Weight
Lbs (kg)

Weathershield

Catalog Number

2

45

2 at +2.5%

2 at –2.5%

150

NH3

—

—

Included

V46D28T45E3R

75

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V46D28T75E3R

2

112.5

2 at +2.5%

2 at –2.5%

150

NH4

—

—

Included

V46D28T12E3R

2

150

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D28T49E3R

225

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D28T22E3R

2

300

2 at +2.5%

2 at –2.5%

150

NJ1

—

—

Included

V46D28T33E3R

500

2 at +2.5%

2 at –2.5%

150

NJ2

—

—

Included

V46D28T55E3R

2

750

2 at +2.5%

2 at –2.5%

150

NJ3

—

—

Included

V46D28T77E3R

2

45

2 at +2.5%

2 at –2.5%

115

NH3

—

—

Included

V46D28F45E3R

75

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V46D28F75E3R

2

112.5

2 at +2.5%

2 at –2.5%

115

NH4

—

—

Included

V46D28F12E3R

150

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D28F49E3R

2

225

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D28F22E3R

300

2 at +2.5%

2 at –2.5%

115

NJ1

—

—

Included

V46D28F33E3R

2

500

2 at +2.5%

2 at –2.5%

115

NJ2

—

—

Included

V46D28F55E3R

2

750

2 at +2.5%

2 at –2.5%

115

NJ3

—

—

Included

V46D28F77E3R

45

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V46D28B45E3R

2

75

2 at +2.5%

2 at –2.5%

80

NH4

—

—

Included

V46D28B75E3R

112.5

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D28B12E3R

2

150

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D28B49E3R

225

2 at +2.5%

2 at –2.5%

80

NJ1

—

—

Included

V46D28B22E3R

300

2 at +2.5%

2 at –2.5%

80

NJ2

—

—

Included

V46D28B33E3R

500

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V46D28B55E3R

750

2 at +2.5%

2 at –2.5%

80

NJ3

—

—

Included

V46D28B77E3R

2
2
2
2

Full Capacity Taps

Note
Contact your local Eaton sales office for CE Mark transformer requirements. For other ratings or catalog numbers not shown, or for special enclosure types (including stainless steel), refer to Eaton.
Frame drawings/dimensions information begins on Page V2-T2-216.

2
2
2
2
2
2
2
2
2
2
2
V2-T2-184

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Transformer Standards, Technical Data and Accessories

Dry-Type Distribution Transformers

2.6

Contents
Description
Standards and Certifications . . . . . . . . . . . . . . . . .
Catalog Number Selection. . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories. . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . .
Glossary of Transformer Terms . . . . . . . . . . . . . . .
Frequently Asked Questions About Transformers .

Page
V2-T2-186
V2-T2-187
V2-T2-189
V2-T2-191
V2-T2-195
V2-T2-211
V2-T2-214

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-185

2.6
2

Transformers
Transformer Standards, Technical Data and Accessories

Standards and Certifications
Eaton dry-type distribution transformers are approved, listed, recognized or may comply with the following standards.

2
2
2
2

Engineering Standards
Catalog
Product
Name

UL
Standard 1

UL/cUL
File
Number

UL Listed
Control
Number

cUL Energy
Efficiency
File Number

CSA
File
Number

Insulation
System
Temp/ºC

kVA
SinglePhase

kVA
ThreePhase

Applicable
IEC
Standard

Industrial Control Transformer
MTE

5085

E46323

702X

—

LR27533

105

0.025–1.5

N/A

61558

2

MTK

5085

E46323

702X

—

LR27533

180

0.05–5

N/A

61558

2

AP

5085

E10156

591H

—

—

180

3–10

N/A

61558

2

AP

1561

E78389

591H

—

—

180

15

N/A

61558

EP

5085

E10156

591H

—

LR60545

180

0.05–10

N/A

61558

2

EP

1561

E78389

591H

EV157 2

LR60545 3

180

15–50

N/A

61558 4 / 726 5

EPT

5085

E10156

591H

—

LR60545

180

N/A

3–9

61558 6 / 726 7

Encapsulated Transformer

2

EPT

1561

E78389

591H

EV157 8

LR60545 9

180

N/A

15–75

726

2

MPC

1062

E53449

591H

—

LR60546

180

3–25

15–30

—

Ventilated Transformer
60726

2

DS-3

1561

E78389

591H

—

—

220

15–167

N/A

DT-3

1561

E78389

591H

—

—

220

N/A

15–750

60726

2

KT

1561

E78389

591H

—

—

220

N/A

9–500

N/A

2

Notes
1 UL 5085 replaces UL 506.
2 Applies to 25–50 kVA.
3 Applies to 25 kVA.
4 Applies to 15–25 kVA.
5 Applies to 37.5 kVA.
6 Applies to 3 kVA.
7 Applies to 5–9 kVA.
8 Applies to 30–75 kVA.
9 Applies to 30 kVA.

2
2
2
2
2
2
2

In addition to the above standards, Eaton
dry-type distribution transformers are also
manufactured in compliance with the
applicable standards listed below.
Not all of the following standards apply
to every transformer.
NEC: National Electrical Code
NEMA ST-1: Specialty Transformers (C89.1)
(control transformers).
NEMA ST-20: General-Purpose
Transformers.
NEMA TP-1: Guide for Determining Energy
Efficiency for Distribution Transformers.
NEMA 250: Enclosures for Electrical
Equipment (1000 volts maximum).
IEEE C57.12.01: General Requirements
for Dry-Type Distribution and Power
Transformers (including those with solidcast and/or resin-encapsulated windings).

ANSI C57.12.70: Terminal Markings and
Connections for Distribution and Power
Transformers.
ANSI C57.12.91: Standard Test Code
for Dry-Type Distribution and Power
Transformers.
CSA C22 No. 47-M90: Air-Cooled
Transformers (Dry-Type).
CSA C9-M1981: Dry-Type Transformers.
CSA C22.2 No. 66: Specialty Transformers.
CSA 802-94: Maximum Losses for
Distribution, Power and Dry-Type
Transformers.
NEMA TP-2: Standard Test Method for
Measuring the Energy Consumption of
Distribution Transformers.
NEMA TP-3

2
2
2
2
2
2
2
2
2
V2-T2-186

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Catalog Number Selection

2

General-Purpose, Energy-Efficient, Mini–Power Center, Shielded Isolation, Nonlinear, Buck-Boost, Marine Duty Transformers—
Example: S20N11S05A

T S 20 N 11 S 05 A
Prefix Options
C = CSA labeled ventilated transformer
Marine Duty
QS = EPM marine (1-Ph encapsulated)
LY = EPTM Marine (3-Ph encapsulated)
RT = DS-3M marine (1-Ph ventilated)
MV = DT-3M marine (3-Ph ventilated)

S
Y
T
V
P
Z
X

=
=
=
=
=
=
=

Type
EP (single-phase encapsulated)
EPT (three-phase encapsulated)
DS-3 (single-phase ventilated)
DT-3 (three-phase ventilated)
Mini–power center
Class 1 Division 2 Groups A, B, C, D
Harmonic mitigating
(three-phase ventilated)

Nonlinear
H = KT-4 (three-phase ventilated)
B = KT-9 (three-phase ventilated)
N = KT-13 (three-phase ventilated)
G = KT-20 (three-phase ventilated)
J = KT-30 (three-phase ventilated)
A = KT-40 (three-phase ventilated)
K = KT-50 (three-phase ventilated)
HT = KT-4 (single-phase ventilated)
NT = KT-13 (single-phase ventilated)
GT = KT-20 (single-phase ventilated)

D
E
F
G
J
K
L
M
N
R
P

Primary Voltage
= 110 x 220
= 120
= 120 x 240
= 208
= 200
= 220
= 230
= 240
= 240 x 480
= 277
= 380
= 400
= 416
= 440
= 450
= 480
= 575
= 600
= 2400
= 4160
= 4800
= Export model
= 120/208/240/277

=
=
=
=
=
=
=
=
=
=
=

T =
U =
W=
X =

Notes
1 Model number is not used on newly
designed/redesigned transformers.
2 Copper windings.
3 Grade 304 stainless steel enclosure
(does not imply a NEMA 4X rating).
4 Open type core and coil assembly.
5 Totally enclosed non-ventilated DS-3
or DT-3.
6 50/60 Hz.
7 Low sound design. LS47 indicates low
sound equal to 47 dB; LS42 indicates
42 dB.

Taps
2 at +2.5%, 2 at –2.5%
1 at +5%, 1 at –5%
1 at –10%
2 at –5%
4 at –2.5%
1 at –10% x 2 at –5%
2 at –5% x 4 at –2.5%
2 at +2.5%, 4 at –2.5%
None
1 at +5%, 2 at –5%
1 at +5%, 2 at –5% x
2 at +2.5%, 4 at –2.5%
1 at +4.2%, 1 at –4.2%
1 at +2.5%, 3 at –2.5%
1 at +3.5%, 1 at –3.5%
2 at +3.1%, 2 at –3.1%

81 =
85 =
82 =
83 =
26 =
51 =
76 =
01 =
16 =
02 =

0.05
0.075
0.10
0.15
0.25
0.50
0.75
1
1.5
2

03 =
05 =
06 =
07 =
09 =
10 =
15 =
21 =
25 =
30 =

3
5
6
7.5
9
10
15
22.5
25
30

kVA
37 = 37.5
45 = 45
50 = 50
75 = 75
99 = 100
12 = 112.5
49 = 150
67 = 167
22 = 225

52 =
33 =
54 =
55 =
60 =
77 =
11 =
14 =

250
300
333
500
600
750
1000
1500

Temperature Rise
T = 150°C rise with 220°C
J = 80°C rise with 220°C
insulation system
insulation system
(ventilated)
(ventilated)
F = 115°C rise with 220°C
P = 115°C rise with 130°C
insulation system
insulation system
(ventilated)
(encapsulated)
B = 80°C rise with 220°C
S = 115°C rise with 180°C
insulation system
insulation system
(ventilated)
(encapsulated and
H = 130°C rise with 200°C
MPC)
insulation system
L = 80°C rise with 180°C
(ventilated)
insulation system
G = 115°C rise with 200°C
(encapsulated and
insulation system
MPC)
(ventilated)

04
06
08
14
12
10
11
54
19
28
29
25
31
26
22
64
24

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

2
2

Suffix Options
13
12
10
29
72
25
23
24
20
27
38
39
43
44
45
48
57
60
42
46
49
40
54

2

A...Y =
CU =
SS =
ZZ =
NV =
X
=
LS_ _ =
AF =
TR =
SR =
CE =
T
=
EE =
NON =
POS =
NEG =
THR =
E3
=
SS4X =
Z
=
S6 =
I2
=
I3
=
I4
=
N3 =

1
2

2
2

3
4

2

5
6
7

2

8
9

2

j
k
l

2

m
n

2

o
p
q

2

r
s

2

t

BK
BL
BM
BN
BO

2
2
2

Secondary Voltage
12/24
20 = 240 x 480
16/32
21 = 240/480
24/48
27 = 277
110/220
38 = 380 delta
120
37 = 380Y/220
120 x 240
34 = 400Y/231
120/240
51 = 416Y/240
127/254
35 = 440Y/254
190Y/110
62 = 460Y/266
208Y/120
47 = 480Y/277
208
48 = 480 delta
220 delta
60 = 600 delta
220Y/127
61 = 600Y/346
220 delta/110 midtap
42 = 2400
240 delta/120 midtap
41 = 4160Y/2400
240Y/139
46 = 4160
240 delta
49 = 4800

2
2
2
2
2
2
2
2

8
9

j
k
l

m

Fungus proof.
Certified test report of standard
production tests for the specific serial
number to be shipped.
Certified sound level report.
CE Marked.
Thermal indicator embedded in center
coil. Suffix “TT” indicates two thermal
indicators of different temperature
ratings, are installed.
NEMA TP-1 efficient.

n
o
p
q
r
s
t

BK
BL
BM
BN
BO

0° phase-shift (used with HMTs).
+15° phase-shift (used with HMTs).
–15° phase-shift (used with HMTs).
–30° phase-shift (used with HMTs).
CSL3 DOE 2007 energy-efficient.
NEMA 4X Grade 304 stainless steel
enclosure.
Easy install base.
Grade 316 stainless steel enclosure
(does not imply NEMA 4X rating).
Integral 2-inch infrared viewing window.
Integral 3-inch infrared viewing window.
Integral 4-inch infrared viewing window.
NEMA Premium® Efficient.

For Eaton’s industrial control transformers
catalog number selection, see Page
V2-T2-188.
Contact your local Eaton sales office for
voltage combinations not shown. Use table
for catalog number breakdown only.
Do not use to create catalog numbers
because all combinations may not be valid.

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2
2
2
2
2
2

V2-T2-187

2.6
2

Transformers
Transformer Standards, Technical Data and Accessories

Motor Drive Isolation Transformers—Example: MD145E89B

MD 145 E 89 B

2
2
2

Type
MD = DT-3
HD = KT-4
ND = KT-13

2
2
2
2

075
11
14
20
27
34
40
51
63
75
93
118
145

=
=
=
=
=
=
=
=
=
=
=
=
=

7.5
11
14
20
27
34
40
51
63
75
93
118
145

kVA
175 =
220 =
275 =
330 =
440 =
550 =
660 =
770 =
880 =
1000 =
1250 =
1500 =

175
220
275
330
440
550
660
770
880
1000
1250
1500

Taps 1
D = 2 at +2.5%, 2 at –2.5%
E = 1 at +5%, 1 at –5%

2
2
2
2
2

82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Voltage
Primary
230 delta
208 delta
240 delta
208 delta
208 delta
208 delta
230 delta
230 delta
230 delta
460 delta
460 delta
460 delta
575 delta
575 delta
575 delta
575 delta
600 delta

Notes
1 For other tap combinations, contact your local Eaton sales office.
Contact your local Eaton sales office for voltage combinations not shown. Use table for catalog number
breakdown only. Do not use to create catalog numbers because all combinations may not be valid.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-188

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Secondary
208Y/120
208Y/120
480 delta
230Y/133
460Y/266
480 delta
230Y/133
460Y/266
575Y/332
230Y/133
460Y/266
575Y/332
230Y/133
460Y/266
575Y/332
480 delta
480 delta

Y =
ES =
CU=
F =
B =
X =

Suffix Options
Encapsulated (Type EPT) design
Electrostatic shield
Copper windings
115°C rise
80°C rise
50/60 Hz

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Product Selection

2

Single-Phase Transformers
How to Select Single-Phase Units
1. Determine the primary (source) voltage—the voltage
presently available.
2. Determine the secondary (load) voltage—the voltage
needed at the load.
3. Determine the kVA load:
– If the load is defined in kVA, a transformer can be
selected from the tabulated data
– If the load rating is given in amperes, determine the load
kVA from the chart (below right). To determine kVA when
volts and amperes are known, use the formula:
Volts Amperes
kVA = ---------------------------------------1000

– If the load is an AC motor, determine the minimum
transformer kVA from the chart at the right
– Select a transformer rating equal to or greater than
the load kVA.
4. Define tap arrangements needed.

2

Single-Phase AC Motors
Full Load Amperes
Horsepower

115 Volts

208 Volts

220 Volts

230 Volts

Minimum
Transformer
kVA 1

1/6

4.4

2.4

2.3

2.2

0.53

1/4

5.8

3.2

3.0

2.9

0.70

1/3

7.2

4.0

3.8

3.6

0.87

1/2

9.8

5.4

5.1

4.9

1.18

3/4

13.8

7.6

7.2

6.9

1.66

1

16

8.8

8.4

8

1.92

1-1/2

20

11.0

10.4

10

2.40

2

24

13.2

12.5

12

2.88

3

34

18.7

17.8

17

4.10

5

56

30.8

29.3

28

6.72

7-1/2

80

44

42

40

9.6

10

100

55

52

50

12.0

2
2
2
2
2
2
2

Voltage

Using the above procedure, select the transformer from the
listings in this catalog.

2
2

Full Load Current in Amperes—Single-Phase Circuits

5. Define temperature rise.

2

kVA

120

208

220

240

277

480

600

2400

4160

0.25

2.0

1.2

1.1

1.0

0.9

0.5

0.4

0.10

0.06

0.50

4.2

2.4

2.3

2.1

1.8

1.0

0.8

0.21

0.12

0.75

6.3

3.6

3.4

3.1

2.7

1.6

1.3

0.31

0.18

1

8.3

4.8

4.5

4.2

3.6

2.1

1.7

0.42

0.24

1.5

12.5

7.2

6.8

6.2

5.4

3.1

2.5

0.63

0.36

2

16.7

9.6

9.1

8.3

7.2

4.2

3.3

0.83

0.48

3

25

14.4

13.6

12.5

10.8

6.2

5.0

1.2

0.72

5

41

24.0

22.7

20.8

18.0

10.4

8.3

2.1

1.2

7.5

62

36

34

31

27

15.6

12.5

3.1

1.8

10

83

48

45

41

36

20.8

16.7

4.2

2.4

15

125

72

68

62

54

31

25

6.2

3.6

25

208

120

114

104

90

52

41

10.4

6.0

37.5

312

180

170

156

135

78

62

15.6

9.0

50

416

240

227

208

180

104

83

20.8

12.0

75

625

360

341

312

270

156

125

31.3

18.0

100

833

480

455

416

361

208

166

41.7

24.0

167

1391

802

759

695

602

347

278

69.6

40.1

Notes
1 If motors are started more than once per hour, increase minimum transformer kVA by 20%.
When motor service factor is greater than 1, increase full load amperes proportionally.
Example: If service factor is 1.15, increase above ampere values by 15%.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-189

2.6

Transformers
Transformer Standards, Technical Data and Accessories

2

Three-Phase Transformers

2

How to Select Three-Phase Units
1. Determine the primary (source) voltage—the voltage
presently available.

2
2
2
2
2

Three-Phase AC Motors
Full Load Amperes

Horsepower

2. Determine the secondary (load) voltage—the voltage
needed at the load.
3. Determine the kVA load:
– If the load is defined in kVA, a transformer can be
selected from the tabulated data
– If the load rating is given in amperes, determine the load
kVA from the chart (below right). To determine kVA when
volts and amperes are known, use the formula:

Minimum
Transformer
208 Volts 230 Volts 380 Volts 460 Volts 575 Volts kVA 1

0.5

2.2

2.0

1.2

1.0

0.8

0.9

3/4

3.1

2.8

1.7

1.4

1.1

1.2

1

4.0

3.6

2.2

1.8

1.4

1.5

1.5

5.7

5.2

3.1

2.6

2.1

2.1

2

7.5

6.8

4.1

3.4

2.7

2.7

3

10.7

9.6

5.8

4.8

3.9

3.8

5

16.7

15.2

9.2

7.6

6.1

6.3

7.5

24

22

14

11

9

9.2

10

31

28

17

14

11

11.2

15

46

42

26

21

17

16.6

20

59

54

33

27

22

21.6

25

75

68

41

34

27

26.6

30

88

80

48

40

32

32.4

40

114

104

63

52

41

43.2

50

143

130

79

65

52

52

60

170

154

93

77

62

64

75

211

192

116

96

77

80

100

273

248

150

124

99

103

2

125

342

312

189

156

125

130

2

150

396

360

218

180

144

150

200

528

480

291

240

192

200

2
2
2
2
2
2

Volts Amperes 1.732
kVA = -----------------------------------------------------------1000

– If the load is an AC motor, determine the minimum
transformer kVA from the chart at the right
– Select a transformer rating equal to or greater than
the load kVA
4. Define tap arrangements needed.
5. Define temperature rise.
Using the above procedure, select the transformer from the
listings in this catalog.

2

Full Load Current in Amperes—Three-Phase Circuits

2

kVA

208

240

380

480

600

2400

4160

3
6
9

8.3
16.6
25

7.2
14.4
21.6

4.6
9.1
13.7

3.6
7.2
10.8

2.9
5.8
8.6

0.72
1.4
2.2

0.42
0.83
1.2

15
22.5
30

41.7
62.4
83.4

36.1
54.1
72.3

22.8
34.2
45.6

18.0
27.1
36.1

14.4
21.6
28.9

3.6
5.4
7.2

2.1
3.1
4.2

37.5
45
50

104
124
139

90.3
108
120

57.0
68.4
76

45.2
54.2
60.1

36.1
43.4
48.1

9.0
10.8
12.0

5.2
6.3
6.9

75
112.5
150

208
312
416

180
270
360

114
171
228

90
135
180

72
108
144

18.0
27.1
36.1

10.4
15.6
20.8

225
300
500

624
832
1387

541
721
1202

342
456
760

270
360
601

216
288
481

54.2
72.2
120

31.3
41.6
69.4

750
1000

2084
2779

1806
2408

1140
1519

903
1204

723
963

180
241

104
139

Voltage

2
2
2
2
2
2
2
2

Notes
1 If motors are started more than once per hour, increase minimum transformer kVA by 20%.

2

When motor service factor is greater than 1, increase full load amperes proportionally.
Example: If service factor is 1.15, increase above ampere values by 15%.

2
2
2
2
V2-T2-190

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Options and Accessories

2

(Order separately)

Weathershield Kit

Weathershield Kit

2

Terminal Extension Kit

A weathershield kit
consisting of a front and rear
cover shield must be installed
on all ventilated dry-type
distribution transformers
when the unit is located
outdoors. The shields
protect the transformer top
ventilation openings against
rain but allow for proper

ventilation. Field installation
hardware is not required.
Refer to specific transformer
listing for selection of
weathershield kit. Proper
installation provides a
NEMA 3R rating.
Note: For 316 stainless steel,
add the suffix ‘S’ to the catalog
number.

A terminal extension kit is
used to allow front access
to the rear terminals on most
500 and 750 kVA transformers
(transformers on frames 919
and 920) when insufficient
space is available at the rear
of the transformer. Eaton
recommends a minimum
6-inch clearance from the wall
to maintain proper ventilation.

Terminal Extension Kit
Fits Frame
Size(s) 1

Bus
Material

Catalog
Number

919

Aluminum

EXT55AL

919

Copper

EXT55CU

920

Aluminum

EXT77AL

920

Copper

EXT77CU

Fits Frame Size(s) 1

Catalog
Number 2

809, 810, 811, 816, 817, 818

WS11

814, 814E

WS13

815

WS15

819, 820

WS16

808, 908, 909, 910, 911, 912, 910A, 911A, 912A

WS31

912B, 912Z, 912D

WS38

812, 813, 913A, 913B, 914A, 915A, 916, 914B, 915B WS33

Wall-mounting brackets are
used to wall-mount ventilated
transformers. This bracket
allows the transformer to
be installed with the proper
clearance, as recommended
by Eaton.

2
2
2
2
2

Wall-Mounting Bracket

Weathershield Kit

2

Wall-mounting brackets are
compatible with the following
frames.

2
2
2
2

Wall-Mounting
Bracket

Availability Guide Wall-Mounting
Bracket WMB01

2

Catalog
Number

914D, 915D, 914F, 915F, 914Z, 915Z

WS39

916A, 916B, 912Z

WS19

917, 918, 918A

WS34

919, 920, 919E, 919EX, 920E, 920EX

WS35

922

WS36

923

WS37

842

WS45

843

WS43

908, 909, 910, 911, 912, 910A, 911A, 912A,
WMB01
912B, 912D, 913A, 913B, 914A, 914B, 914D,
915D, 915A, 915B, 914F, 915F, 912Z, 914Z, 915Z

844

WS44

939, 940

WMB05

939

WS57

942, 943

WMB04

940

WS58

942

WS59

943

WS60

944

WS61

945

WS62

Notes
1 Effective June 1, 2001, frame numbers will have a prefix of
FR, e.g., FR819. Dimensions, accessories and so on are still
applicable as if the FR did not exist.
2 For Grade 316 stainless steel weathershields, add the suffix “S”
to a catalog number, e.g., WS31S.

Frame Sizes 1

Type DS-3 (Single-Phase Compatible)
809, 810, 811, 812, 813, 815, 816, 817,
818, 835, 836, 837, 814A, 842

WMB01

2
2
2

Type DT-3, K-Factor, Drive Isolation
(Three-Phase Compatible)

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-191

2.6

Transformers
Transformer Standards, Technical Data and Accessories

2

Terminal Lug Kits for Type DT-3 Transformers

2

Typical Sizing

Cable Range

Quantity

Bolt Size

Quantity

Catalog Number

15–37.5 kVA single-phase
15–45 kVA three-phase

#14–#2
#6–250 kcmil

8
4

1/4-20 x 3/4

8

LKS1

50–75 kVA single-phase
75–112.5 kVA three-phase

#6–250 kcmil

12

1/4-20 x 3/4
1/4-20 x 1-3/4

8
8

LKS2

100–167 kVA single-phase
150–300 kVA three-phase

#6–250 kcmil
#2–600 kcmil

3
22

1/4-20 x 3/4
3/8-16 x 2

3
16

LKS3

500 kVA three-phase

#2–600 kcmil

29

3/8-16 x 2

18

LKS4

2
2
2
2
2

Terminal Lugs

Hardware

Rodent Screens

Replacement Parts for Mini–Power Centers
Frame

Deadfront Cover
(Breaker Cover)

Front Cover

Description

Frame Size(s) 1

Catalog
Number

Rodent screens are used to
discourage entry by birds
or rodents.

908, 909

RS01

283

47-37503

7074C98H04

910A, 911, 912

RS02

284

47-37503-2

7074C98H01

913B, 914B, 915B

RS03

285

47-37503-3

7074C98H02

2

916

RS04

286

47-37503-4

7074C98H02

917, 918, 918A

RS05

287

47-37503-5

7074C98H03

2

919, 920, 919E, 919EX, 920E, 920EX

RS06

289

47-37459

7074C44H01

916A, 916B

RS07

290

47-37459-2

7074C44H02

2

922

RS08

291

47-37459-3

7074C44H03

2

923

RS09

289A

47-42072-1

7074C44H01

814, 821, 814E

RS11

290A

47-42072-2

7074C44H02

2

815

RS12

291A

47-42072-3

7074C44H03

816

RS13

2

817, 818

RS14

Notes
1 Effective June 1, 2001, frame numbers will have a prefix of FR, e.g., FR819. Dimensions,
accessories and so on are still applicable as if the FR did not exist.

2
2

819, 820

RS15

2

842

RS42

2

843

RS43

844

RS44

2

912B, 912Z, 912D

RS16

914D, 915D, 914F, 915F, 914Z, 915Z

RS17

2

916Z

RS07

2

939

RS57

940

RS58

2

942

RS59

943

RS60

2

944

RS61

945

RS62

Lugs are rated Al/Cu and are suitable for use with either aluminum or copper conductors.

2
2
2
2
2
2
2
2
V2-T2-192

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Transformer Standards, Technical Data and Accessories

2.6

Case Parts for Ventilated Units

2

Front Panel
(Upper)

Front Panel
(Lower)

Back Panel
(Upper)

Back Panel
(Lower)

Front or Back
Panel (Cutout
Cover Plate)

Top
Cover

Side Panel
(Two Required
per Transformer)

Bottom

809

7073C16P03

—

7073C16P03

—

—

7073C17P01

7073C18P04

7073C14P03

810

7073C16P01

—

7073C16P01

—

—

7073C17P01

7073C18P01

7073C14P01

811

7073C16P01

—

7073C16P01

—

—

7073C17P01

7073C18P01

7073C14P01

812

7073C16P02

—

7073C16P02

—

—

7073C17P02

7073C18P02

7073C14P02

813

7073C16P02

—

7073C16P02

—

—

7073C17P02

7073C18P02

7073C14P02

Frame(s) 1
Single-Phase

814, 814E

7073C54P01

—

7073C54P01

—

—

7073C17P03

7073C18P05

7073C14P04

815

47-39433

—

47-39433

—

—

47-39431

47-39430

47-39429

816

47-40452

—

47-40452

—

—

47-40453

47-40451

47-40449

817

47-40457

—

47-40457

—

—

47-40458

47-40456

47-40454

818

47-40457

—

47-40457

—

—

47-40458

47-40456

47-40454

819

47-40574

—

47-40574

—

—

47-40575

47-40573

47-40459

820

47-40574

—

47-40574

—

—

47-40575

47-40573

47-40459

842

47-54828-2

—

47-54828-2

—

—

47-54829-2

47-54827-2

47-55335-2

843

47-54828-4

—

47-54828-4

—

—

47-54829-4

47-54827-4

47-55335-3

844

47-54828-5

—

47-54828-5

—

—

47-54829-5

47-54827-5

47-55335-5

2
2
2
2
2
2
2
2
2
2
2

Notes
1 Effective June 1, 2001, frame numbers will have a prefix of FR, e.g., FR819. Dimensions, accessories and so on are still applicable as if the FR did not exist.
Parts listed are for standard catalog listed transformers. Units with modifications may require different parts. (Frame number from transformer nameplate required.) Transformer nameplate and UL label
are not field replaceable.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-193

2.6
2
2

Transformers
Transformer Standards, Technical Data and Accessories

Case Parts for Ventilated Units, continued

Frame(s) 1

Front Panel
(Upper)

Front Panel
(Lower)

Back Panel
(Upper)

Back Panel
(Lower)

Front or Back
Panel (Cutout
Cover Plate)

Top
Cover

Side Panel
(Two Required
per Transformer)

Bottom

2

Three-Phase
908

7073C37P01

—

7073C37P01

—

—

1714C45P01

1714C44P03

7073C20P05

2

909

7073C37P01

—

7073C37P01

—

—

1714C45P01

1714C44P03

7073C20P05

2

910

1714C46P01

—

1714C46P01

—

—

1714C45P01

1714C44P01

7073C20P01

911

1714C46P01

—

1714C46P01

—

—

1714C45P01

1714C44P01

7073C20P01

2

912

1714C46P01

—

1714C46P01

—

—

1714C45P01

1714C44P01

7073C20P01

916

1714C60P01

—

1714C60P01

—

—

1714C58P01

1714C56P01

7073C20P03

2

917

47-44973-1

—

47-44973-1

—

—

1714C67P01

1714C64P01

7073C20P04

918

47-44973-1

—

47-44973-1

—

—

1714C67P01

1714C64P01

7073C20P04

2D46331P04

2D46331P03

2D46331P04

2D46331P01

2D46331P02

2D46332P01

2D46331P04

2D46331P01

2

919, 919E, 919EX 2D46331P03

2

920, 920E, 920EX 2D46331P03

2D46331P04

2D46331P03

2D46331P04

922

2D46391H06

2D46391H08

2D46391H03

2D46391H08

2D46331P02

2D46332P01

2D46331P04

2D46391H02

2D46392H01

—

2

923

47-45927-1

—

47-45927-1

—

—

47-45926-1

47-45925-1

47-45759-1

910A

47-40592

—

47-40592

—

—

1714C45P01

47-40591

47-40589

2

911A

47-40592

—

47-40592

—

—

1714C45P01

47-40591

47-40589

912A

47-40592

—

47-40592

—

—

1714C45P01

47-40591

47-40589

2

912B

47-49323-1

—

47-49323-1

—

—

47-49322-1

47-49321-1

47-49320-1

2

912D

47-55332-2

—

47-55332-2

—

—

47-55331-2

47-55329-2

47-55330-1

912DN

47-55332-4

—

47-55332-4

—

—

47-55331-2

47-55329-2

47-55330-3

2

913A

1714C47P03

—

1714C47P03

—

—

1714C45P02

1714C44P07

7073C30P02

913B

47-40580

—

47-40580

—

—

1714C45P02

47-40578

47-41792

2

914A

1714C47P03

—

1714C47P03

—

—

1714C45P02

1714C44P07

7073C30P02

2

914B

47-40580

—

47-40580

—

—

1714C45P02

47-40578

47-41792

914D

47-49317-1

—

47-49317-1

—

—

47-49316-1

47-49315-1

47-49314-1

2

914F/915F

47-56915-1

—

47-56915-1

—

—

47-56916-1

47-56917-1

47-56918-1

915A

1714C47P03

—

1714C47P03

—

—

1714C45P02

1714C44P07

7073C30P02

2

915B

47-40580

—

47-40580

—

—

1714C45P02

47-40578

47-41792

915D

47-49317-1

—

47-49317-1

—

—

47-49316-1

47-49315-1

47-49314-1

2

916A

47-41790

—

47-41790

—

—

47-41791

47-41789

47-41788

2

918A

47-41801

—

47-41801

—

—

47-41802

47-41800

47-41802

912Z

47-49323-1

—

47-49323-1

—

—

47-49322-1

47-49991-1

47-49989-1

2

915Z

47-49317-1

—

47-49317-1

—

—

47-49316-1

47-49994-1

47-49995-1

916Z

47-49992-1

—

47-49992-1

—

—

47-41791

47-49988-1

47-49987-1

2

939

73-5902-1

—

73-5902-1

—

—

73-5903-1

73-5900-1

73-5901-1

940

73-5902-2

—

73-5902-2

—

—

73-5903-2

73-5900-2

73-5901-2

2

942

73-5902-3

—

73-5902-3

—

—

73-5903-3

73-5900-3

73-5901-3

2

943

73-5902-4

—

73-5902-4

—

—

73-5903-4

73-5900-4

73-5901-4

944

73-5902-5

—

73-5902-5

—

—

73-5903-5

73-5900-5

73-5901-5

945

73-5902-6

—

73-5902-6

—

—

73-5903-6

73-5900-6

73-5901-6

2
2
2

Notes
1 Effective June 1, 2001, frame numbers will have a prefix of FR, e.g., FR819. Dimensions, accessories and so on are still applicable as if the FR did not exist.
Parts listed are for standard catalog listed transformers. Units with modifications may require different parts. (Frame number from transformer nameplate required.) Transformer nameplate and UL label
are not field replaceable.

2
2
2
V2-T2-194

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Technical Data and Specifications
Customer-Furnished
Connecting Cables
Eaton recommends that
external cables be rated 90°C
(sized at 75°C ampacity) for
encapsulated designs and
75°C for ventilated designs.
Primary and secondary
terminal lugs are not
included. Lug kits are
available separately.

Overload Capability
Short-term overload capacity is
designed into transformers as
required by ANSI. Dry-type
distribution transformers will
deliver 200% nameplate load
for one-half hour, 150% load
for one hour and 125% load
for four hours without being
damaged, provided that a
constant 50% load precedes
and follows the overload.
See ANSI C57.96-01.250
for additional limitations.
Continuous overload capacity
is not deliberately designed
into a transformer because
the design objective is to be
within the allowed winding
temperature rise with
nameplate loading.

Seismically Qualified
Eaton manufactured dry-type
distribution transformers are
seismically qualified, and
exceed requirements of the
Uniform Building Code (UBC)
and California Code Title 24.

Taps
Primary taps are available
in most ratings to allow
compensation for source
voltage variations.

Series-Multiple Windings
Series-multiple windings
consist of two similar coils in
each winding that can be
connected in series or parallel
(multiple). Transformers with
series-multiple windings are
designated with a “x” or
“/” between the voltage
ratings, such as voltages of
“120/240” or “240 x 480.”
If the series-multiple winding
is designated by an “x,” the
winding can be connected
only for a series or parallel.
With the “/” designation,
a midpoint also becomes

available in addition to the
series or parallel connection.
As an example, a 120 x 240
winding can be connected
for either 120 (parallel) or
240 (series), but a 120/240
winding can be connected for
120 (parallel), 240 (series) or
240 with a 120 midpoint.

Enclosures
Eaton’s ventilated
transformers—Types DS-3,
DT-3, MD and KT—use a
NEMA 2 rated (drip-proof)
enclosure as standard, and
are rated NEMA 3R with the
addition of weathershields.
Eaton encapsulated—Types
EP, EPT, EPZ and EPTZ—
and totally enclosed, nonventilated (Types DS-3E and
DT-3E) transformers use a
NEMA 3R rated enclosure.

Buck-Boost Transformers
An autotransformer has only
one winding, and is therefore
smaller and more economical
than the conventional twowinding transformer. In an
autotransformer, the primary
and secondary are electrically
and mechanically connected.
The required secondary
voltage is obtained by
“tapping-off” from the
single winding.
Buck-boost autotransformers
are insulated units with
120 x 240 or 240 x 480 volt
primaries and 12/24, 16/32 or
24/48 volt secondaries, and
provide a very economical
method for minor voltage
adjustments where circuit
isolation is not needed.
Autotransformers can be
used only where local
electrical codes permit,
and isolation of the two
circuits is not required.

Nonlinear Ratings
The transformers shall be
specifically designed to
supply circuits with a
harmonic profile equal to
or less than a K-factor of
4 or 13, as described in the
following table, without
exceeding specified
temperature rise.

Nonlinear Ratings
Harmonic

K-4

K-13

Fundamental

100.0%

100.0%

3rd

34.0%

70.0%

5th

22.0%

42.0%

7th

3.0%

5.0%

9th

1.0%

3.0%

11th

0.7%

3.0%

13th

0.5%

1.0%

15th

0.3%

0.7%

17th

0.3%

0.6%

transformers and their
installation to minimize
the potential for sound
transmission to surrounding
structures and sound
reflection. It is suggested
that the following installation
methods be included:
1. If possible, mount the
transformer away from
corners of walls or
ceilings. For installation
that must be near a
corner, use soundabsorbing materials on
the walls and ceilings if
necessary to eliminate
reflection.

Sound Levels
All Eaton 600 volt class
general-purpose dry-type
distribution transformers are
designed to meet NEMA
ST-20 sound levels listed
here. These are the sound
levels measured in a
soundproof environment.
Actual sound levels
measured at an installation
will likely be higher (up to
15 dB greater) due to
electrical connections and
environmental conditions.
Lower sound levels are
available and should be
specified when the
transformer is going to be
installed in an area where
sound may be a concern.

2. Provide a solid
foundation for mounting
the transformer and
then use vibration
dampening mounts if
not already provided in
the transformer. (Eaton
encapsulated EP/EPT
designs use a special
encapsulation system
and ventilated DS/DT-3
designs contain a built-in
vibration dampening
system to minimize
and isolate sound
transmission.)

All Eaton general-purpose
dry-type distribution
transformers are designed
with sound levels lower than
NEMA ST-20 maximum levels.
However, consideration
should be given to the
specific location of the

3. Provide flexible conduit
to make the connections
to the transformer.
4. Locate the transformer
as far as possible from
areas where high sound
levels are undesirable.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Average Sound Levels
NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

Encapsulated
(up to 1.2 kV)

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

2
2
2
2

50.01 to 75.00

50

53

55

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

500.01 to 700.00

62

65

61

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2

2
2
2

V2-T2-195

2

2.6
2
2

Transformers
Transformer Standards, Technical Data and Accessories

Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Aluminum Wound 1
Type EP 115°C Rise

2

% Impedance 2

Weight Lbs

Losses in Watts

Efficiency

2

kVA

Al

Cu

No
Load

Total

1/4
Load

1/2
Load

3/4
Load

Full
Load

100%
P.F.

80%
P.F.

Min.

Max.

Sound
Level dB

0.05

—

7

6

9

65.3

79.6

84.3

85.6

5.9

6.4

5.5

9.5

45

2

0.075

—

7

7

14

66.0

79.0

82.5

82.8

9.4

9.2

7.5

11.0

45

0.10

—

7

5

15

82.4

86.9

87.7

86.5

10.3

10.6

8.0

12.0

45

2

0.15

—

8

7

20

83.4

88.2

88.9

87.8

9.0

9.6

8.0

12.0

45

2

0.25

—

12

14

29

79.0

87.2

89.5

89.6

5.9

7.5

7.5

9.5

45

0.5

—

13

20

47

85.1

90.3

91.4

91.4

5.5

7.0

5.0

7.0

45

2

0.75

—

20

29

57

86.0

91.3

92.7

92.9

3.9

5.0

4.0

6.0

45

1

—

30

24

60

90.8

93.9

94.5

94.4

3.8

4.9

3.8

5.8

45

2

1.5

65

40

30

90

92.5

94.7

95.0

94.6

4.1

5.2

2.5

4.5

45

2

113

40

30

100

94.2

95.7

95.8

95.4

3.6

4.7

3.3

5.3

45

2

3

—

69

61

135

92.0

95.0

95.7

95.7

2.5

3.5

2.5

4.1

45

2

5

—

120

104

215

91.8

95.0

95.8

95.9

2.3

3.3

2.0

4.6

45

7.5

123

133

129

250

93.2

96.0

96.7

95.9

1.5

2.4

2.4

3.4

45

10

193

208

153

295

93.9

96.3

97.0

97.2

1.5

2.5

2.0

3.3

50

15

216

235

209

435

94.4

96.6

97.1

97.2

1.6

2.8

1.6

3.6

50

25

385

414

191

440

96.8

98.0

98.3

98.4

1.1

2.5

1.6

4.2

50

37.5

735

856

225

370

97.4

98.3

98.5

98.4

1.2

2.6

2.8

4.0

50

2
2

% Regulation

2
2

Type EPT 115°C Rise 3
% Impedance 2

Weight Lbs

Losses in Watts

Efficiency

kVA

Al

Cu

No
Load

Total

1/4
Load

1/2
Load

3/4
Load

Full
Load

100%
P.F.

80%
P.F.

Min.

Max.

Sound
Level dB

3

116

123

110

165

87.3

92.6

94.3

94.9

2.1

6.1

2.4

8.0

45

6

143

153

145

275

90.9

94.5

95.5

95.7

2.2

3.1

2.9

4.9

45

2

9

166

178

195

375

91.6

95.0

95.9

96.1

2.0

2.8

2.0

3.6

45

2

15

275

300

265

545

93.0

95.7

96.5

96.6

1.9

3.1

1.9

3.9

50

30

422

504

250

665

96.5

97.7

98.0

97.9

1.5

2.5

1.8

3.8

50

2

45

660

745

300

740

97.2

98.2

98.4

98.5

1.0

2.1

1.8

4.0

50

75

1275

1450

400

945

97.7

98.6

98.8

98.8

0.8

1.6

1.7

3.4

55

2

Notes
1 Typical values for aluminum windings. Contact Eaton for values of copper windings. Up-to-date design data is available at www.eaton.com.
2 Actual impedance may be ± 7.5%.
3 Type EPT transformers 3–15 kVA are T-T connected.

2
2

2
2

% Regulation

Performance data is based upon 480 volt Delta primary and a 208Y/120 volt secondary for three-phase transformers; 240 x 480 volt primary and a 120/240 volt secondary for single-phase transformers.
All data is subject to future revision. Refer to Eaton for 5 kV class information. All data is subject to future revision.

2
2
2
2
2
2
2
V2-T2-196

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Aluminum Wound

2
2

Type DS-3 150°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20º)

Total at
Rise +20

25%

50%
97.7

% Regulation

Inrush

75%

Full
Load

100%
PF

80%
PF

% Imp.
Trise
+20

X
Trise
+20

R
Trise
+20

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

97.3

96.7

2.0

2.5

3.46

1.9

2.9

45

97.70

910

303

kVA

Weight

No
Load

15

196

80

518

97.5

25

261

110

736

98.2

98.2

97.8

97.3

1.6

2.1

2.97

1.6

2.5

45

98.00

1477

492

38

304

132

1141

98.3

98.1

97.7

97.1

1.8

3.8

4.85

4.0

2.7

45

98.20

1056

352

50

396

145

1699

98.4

98.1

97.5

96.8

2.1

4.2

5.32

4.3

3.1

45

98.30

1078

359

75

688

260

1622

98.4

98.6

98.3

97.9

1.5

2.7

3.46

2.9

1.8

50

98.50

3428

1143

100

699

300

2527

98.5

98.4

98.1

97.6

1.9

4.0

5.17

4.7

2.2

50

98.60

2596

865

167

1610

900

3987

68.7

98.7

98.4

98.0

1.4

6.8

9.70

9.5

1.8

55

98.70

1250

416

Efficiency (Trise +20º)

Total at
Rise +20

25%

50%

% Regulation

Inrush

75%

Full
Load

100%
PF

80%
PF

% Imp.
Trise
+20

X
Trise
+20

R
Trise
+20

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

kVA

Weight

No
Load

15

246

80

519

97.8

97.8

97.3

96.8

2.1

3.1

3.9

2.6

2.9

45

97.70

773

244

25

373

300

766

97.7

98.1

98.0

97.7

1.4

2.8

3.3

2.8

1.9

45

98.00

1102

367

37.5

380

125

1182

98.2

98.4

98.1

97.8

2.0

3.1

4.1

2.9

2.8

45

98.20

616

205

50

590

300

417

98.4

98.3

97.9

97.4

1.8

4.1

5.2

5.2

0.2

45

98.30

1553

511

75

689

170

2356

98.5

98.2

97.6

97.0

2.7

5.6

6.9

6.3

2.9

50

98.50

1717

572

Efficiency (Trise +20º)

Total at
Rise +20

25%

50%

% Regulation

Inrush

75%

Full
Load

100%
PF

80%
PF

% Imp.
Trise
+20

X
Trise
+20

R
Trise
+20

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

kVA

Weight

No
Load

15

360

115

269

97.4

98.3

98.4

98.4

0.8

1.7

2.0

1.8

1.0

45

97.70

1381

460

25

370

120

580

97.8

98.2

98.0

97.8

1.5

3.2

3.9

3.4

1.8

45

98.00

1046

348

37.5

565

150

834

98.1

98.4

98.1

97.8

1.5

3.3

4.1

3.6

1.8

45

98.20

1471

490

50

680

175

1014

98.4

98.5

98.4

98.1

1.5

3.4

4.2

3.9

1.7

45

98.30

1733

577

75

900

260

1387

98.3

98.6

98.5

98.2

1.4

3.5

4.3

4.0

1.5

50

98.50

2423

807

Total at
Rise +20

Efficiency (Trise +20º)

% Regulation
80%
PF

X
Trise
+20

R
Trise
+20

Weight

15

204

95

778

96.6

96.7

96.0

95.1

4.8

4.0

4.8

1.4

4.6

45

97.00

382

127

30

291

165

1207

97.2

97.3

96.9

96.2

3.7

5.6

4.6

3.0

3.5

45

97.50

479

159

37.5

381

210

1428

97.5

97.5

97.0

96.4

3.5

5.5

4.5

3.1

3.2

45

97.70

484

161

45

351

210

1911

97.5

97.4

96.7

96.0

3.8

6.3

5.1

3.4

3.8

45

97.70

564

188

50

531

270

1316

97.7

98.1

97.9

97.5

2.2

4.0

3.2

2.4

2.1

45

98.00

999

333

75

553

300

2917

97.9

97.7

97.0

96.3

3.6

6.6

5.3

4.0

3.5

50

98.00

561

187

112.5

793

400

3693

98.0

98.0

97.5

96.9

3.2

7.5

6.0

5.2

2.9

50

98.20

1049

350

150

913

490

4923

98.2

98.0

97.5

96.9

3.2

6.5

5.3

4.4

3.0

50

98.30

1518

506

225

1343

650

6476

98.4

98.2

97.8

97.2

2.8

6.3

5.1

4.4

2.6

55

98.50

2204

734

300

1597

750

8239

98.5

98.3

97.9

97.3

2.9

8.9

7.6

7.2

2.5

55

98.60

2097

699

500

2590

1400

9782

98.6

98.7

98.5

98.1

1.9

8.2

7.2

7.0

1.7

60

98.70

3769

1256

750

3340

1800

12,692

98.8

98.9

98.7

98.4

1.8

8.9

8.0

7.9

1.5

64

98.80

4521

1507

75%

100%
PF

% Imp.
Trise
+20

kVA

50%

Full
Load

Inrush

No
Load

25%

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Type DT-3 150°C Rise NEMA TP-1 Efficient
Losses in Watts

2

2

Type DS-3 80°C Rise NEMA TP-1 Efficient
Losses in Watts

2

2

Type DS-3 115°C Rise NEMA TP-1 Efficient
Losses in Watts

2

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Practical
Max.

V2-T2-197

2
2
2
2
2
2
2
2
2

2.6
2
2

Transformers
Transformer Standards, Technical Data and Accessories

Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Aluminum Wound
Type DT-3 115°C Rise NEMA TP-1 Efficient

2

Losses in Watts

% Regulation

Inrush

15

202

100

743

96.7

96.8

96.2

95.4

4.4

3.9

4.4

1.2

4.3

45

97.00

383

127

2

30

311

165

1492

97.3

97.1

96.3

95.5

4.5

4.8

4.8

1.8

4.4

45

97.50

411

137

2

45

418

220

1458

97.8

97.9

97.5

97.0

2.8

5.4

4.6

3.7

2.8

45

97.70

550

183

50

556

270

1211

97.6

98.1

98.0

97.7

1.9

3.7

3.2

2.6

1.9

45

98.00

892

297

2

75

581

300

2415

97.9

97.9

97.5

96.9

3.0

6.7

5.9

5.1

2.8

50

98.00

758

252

112.5

829

440

3209

98.0

98.1

97.8

97.3

2.6

3.6

3.1

1.9

2.5

50

98.20

1301

433

2

150

996

530

3781

98.1

98.3

97.9

97.5

2.4

5.8

5.2

4.7

2.2

50

98.30

1534

511

225

1569

720

5205

98.4

98.4

98.1

97.8

2.2

6.8

6.2

5.8

2.0

55

98.50

1875

631

2

300

1908

830

6926

98.5

98.5

98.2

97.8

2.3

6.0

5.4

4.9

2.0

55

98.60

2678

872

2

500

3117

1650

6968

98.5

98.9

98.8

98.7

1.2

6.6

6.6

6.5

1.1

60

98.70

3930

1310

750

4884

2000

9335

98.9

99.1

99.0

98.8

1.3

8.7

9.0

8.9

1.0

64

98.80

4458

1486

2

75%

80%
PF

R
Trise
+20

2

50%

100%
PF

X
Trise
+20

Weight

25%

Full
Load

% Imp.
Trise
+20

kVA

2

Total at
Rise +20

Efficiency (Trise +20º)

No
Load

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

Type DT-3 80°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20º)
50%

Inrush

75%

100%
PF

80%
PF

% Imp.
Trise
+20

X
Trise
+20

R
Trise
+20

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.
119

Weight

2

15

276

165

551

96.7

97.4

97.2

96.8

3.4

3.9

3.5

2.3

2.6

45

97.00

358

30

350

180

904

97.3

97.8

97.6

97.2

2.5

3.9

3.4

2.5

2.4

45

97.50

337

112

2

45

540

290

1027

97.7

98.2

98.2

97.9

1.7

3.5

3.3

2.9

1.6

45

97.70

953

317

75

810

360

1782

97.8

98.2

98.0

97.7

0.3

3.5

4.3

3.9

1.9

50

98.00

1006

355

2

112.5

944

470

2521

98.2

98.4

98.2

97.9

1.9

4.4

4.1

3.7

1.8

50

98.20

1554

518

2

150

1438

650

2760

98.2

98.6

98.5

98.3

1.5

4.8

4.7

4.5

1.4

50

98.30

1665

555

225

1746

830

4047

98.3

98.6

98.5

98.3

1.6

5.5

5.6

5.4

1.4

55

98.50

2003

667

300

2400

1100

5338

98.6

99.0

99.0

98.9

1.6

5.9

6.1

5.9

1.4

55

98.60

2655

885

500

3418

1800

5858

98.6

99.0

99.0

98.9

0.9

4.9

5.4

5.3

0.8

60

98.70

4462

1487

% Imp.
Trise
+20

X
Trise
+20

R
Trise
+20

Sound
Level dB

TP1
Efficiency

Absolute
Max.

2

25%

% Regulation

kVA

2

Total at
Rise +20

Full
Load

No
Load

2
2
2

Type KT-4 150°C Rise NEMA TP-1 Efficient
Losses in Watts

% Regulation

Weight

2

15

206

100

883

96.7

96.5

95.6

94.6

5.5

5.2

5.5

1.8

5.2

45

97.00

375

125

30

311

165

1263

97.2

97.3

96.7

96.0

3.9

7.4

6.0

4.8

3.7

45

97.50

453

151

2

45

400

220

1554

97.7

97.7

97.3

96.7

3.2

5.9

4.8

3.8

3.0

45

97.70

710

236

2

75

547

300

2622

97.9

97.8

97.2

96.6

3.3

6.7

5.3

4.4

3.1

50

98.00

995

331

112.5

800

440

3525

98.0

98.0

97.6

97.0

3.0

7.4

6.0

5.3

2.7

50

98.20

1082

360

2

150

1010

530

4055

98.1

98.2

97.8

97.4

2.6

6.6

5.4

4.8

2.3

50

98.30

1574

524

225

1680

700

5879

98.3

98.3

97.9

97.5

2.6

7.6

6.3

5.9

2.3

55

98.50

1943

647

2

300

2122

1100

5895

98.4

98.6

98.4

98.1

1.9

6.8

5.9

5.7

1.6

55

98.60

2863

954

500

3201

1800

7054

98.5

98.9

98.8

98.7

1.3

5.9

5.4

5.2

1.1

60

98.70

4588

1529

25%

50%

75%

Full
Load

100%
PF

80%
PF

Inrush

kVA

2

Total at
Rise +20

Efficiency (Trise +20º)

No
Load

2
2
2
V2-T2-198

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Practical
Max.

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Aluminum Wound

2
2

Type KT-4 115°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20º)

Total at
Rise +20

25%

50%

% Regulation

Inrush

75%

Full
Load

100%
PF

80%
PF

% Imp.
Trise
+20

X
Trise
+20

R
Trise
+20

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

kVA

Weight

No
Load

15

307

135

394

96.3

97.5

97.6

97.5

1.8

2.7

2.2

1.4

1.7

45

97.00

491

163

30

313

165

1344

97.4

97.3

96.6

95.9

4.1

5.1

4.6

2.4

3.9

45

97.50

584

194

45

400

220

1463

97.8

97.9

97.5

97.0

3.0

6.1

5.2

4.4

2.8

45

97.70

591

197

75

587

285

2355

97.9

97.9

97.5

97.0

2.9

6.7

5.9

5.2

2.8

50

98.00

823

274

112.5

947

470

2910

97.9

98.1

97.9

97.5

2.4

5.0

4.3

3.7

2.2

50

98.20

1447

482

150

1243

560

4119

98.1

98.2

97.8

97.4

2.5

6.6

5.7

5.2

2.4

50

98.30

1468

489

225

1680

700

5413

98.3

98.3

98.1

97.7

2.3

7.5

7.0

6.7

2.1

55

98.50

1719

573

300

2480

1100

5735

98.4

98.7

98.5

98.2

1.8

6.7

6.3

6.1

1.5

55

98.60

2547

849

2
2
2
2
2
2
2
2

Type KT-4 80°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20º)

% Regulation

Inrush

kVA

Weight

No
Load

Total at
Rise +20

25%

50%

75%

Full
Load

100%
PF

80%
PF

% Imp.
Trise
+20

15

378

165

416

96.4

97.6

97.7

97.6

1.7

2.9

2.5

1.9

1.7

45

97.00

482

160

30

365

188

877

97.2

97.7

97.6

97.2

2.4

3.9

3.5

2.6

2.3

45

97.50

583

194

45

550

285

1055

97.4

98.1

98.0

97.8

1.8

3.7

3.4

2.9

1.7

45

97.70

708

236

75

774

360

1784

97.8

98.2

98.0

97.7

2.0

4.7

4.5

4.0

1.9

50

98.00

986

328

X
Trise
+20

R
Trise
+20

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

2
2

112.5

1380

550

1872

97.9

98.5

98.5

98.4

1.3

4.2

4.2

4.1

1.2

50

98.20

1577

525

150

1604

700

2728

98.0

98.5

98.5

98.3

1.4

4.4

4.5

4.3

1.4

50

98.30

1880

626

225

2336

850

3728

98.4

98.7

98.6

98.4

1.4

5.0

5.2

5.1

1.3

55

98.50

2647

882

300

2689

1100

4589

98.4

98.8

98.7

98.5

1.4

5.5

5.8

5.6

1.2

55

98.60

2610

870

Efficiency (Trise +20º)

Total at
Rise +20

25%

50%

96.7

97.3

2
2
2
2

Type KT-13 150°C Rise NEMA TP-1 Efficient
Losses in Watts

2

% Regulation

Inrush

75%

Full
Load

100%
PF

80%
PF

% Imp.
Trise
+20

X
Trise
+20

R
Trise
+20

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

97.0

96.5

3.1

4.2

3.6

2.1

2.9

45

97.00

379

126

kVA

Weight

No
Load

15

271

165

604

30

365

198

977

97.1

97.6

97.3

96.9

2.7

4.3

3.5

2.4

2.6

45

97.50

565

188

45

545

280

1215

97.5

98.0

97.8

97.4

2.2

4.2

3.3

2.6

2.1

45

97.70

890

277

75

812

360

2139

97.7

98.0

97.8

97.4

2.6

5.9

4.9

4.3

2.4

50

98.00

907

302

112.5

920

490

3059

98.0

98.2

97.8

97.4

2.4

5.0

4.1

3.4

2.3

50

98.20

1513

504

150

1221

530

4297

98.1

98.1

97.7

97.2

2.7

6.5

5.3

4.6

2.5

50

98.30

1790

597

225

1960

830

4461

98.3

98.6

98.3

98.0

1.9

6.6

6.1

5.9

1.6

55

98.50

1771

590

300

2358

1100

5931

98.4

98.6

98.4

98.2

1.9

7.2

6.3

6.0

1.6

55

98.60

2543

847

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-199

2.6
2
2

Transformers
Transformer Standards, Technical Data and Accessories

Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Aluminum Wound
Type KT-13 115°C Rise NEMA TP-1 Efficient

2

Losses in Watts

Efficiency (Trise +20º)

Total at
Rise +20

25%

50%

% Regulation

Inrush

75%

Full
Load

100%
PF

80%
PF

% Imp.
Trise
+20

X
Trise
+20

R
Trise
+20

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

2

kVA

Weight

No
Load

15

332

165

432

96.6

97.6

97.6

97.4

1.9

3.2

2.8

2.2

1.8

45

97.00

409

136

2

30

390

200

903

97.3

97.8

97.6

97.2

2.5

4.4

3.6

2.8

2.3

45

97.50

420

120

2

45

548

280

1187

97.5

98.1

98.0

97.7

2.2

—

3.0

2.3

2.0

45

97.70

836

278

75

808

360

1850

97.8

98.1

97.8

97.5

2.4

5.6

4.8

4.3

2.2

50

98.00

805

268

2

112.5

990

540

2373

97.9

98.3

98.2

98.0

1.8

4.5

4.0

3.6

1.6

50

98.20

1303

434

150

1600

650

2372

98.1

98.5

98.4

98.1

1.3

3.4

3.0

2.8

1.1

50

98.30

1932

644

2

225

2306

850

4001

98.3

98.7

98.6

98.3

1.6

4.9

5.1

4.9

1.4

55

98.50

2508

836

300

3291

1100

4583

98.4

98.8

98.7

98.5

1.3

6.2

6.3

6.2

1.2

55

98.60

2851

950

2
2
2

Type KT-13 80°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20º)
25%

50%

% Regulation

Inrush

75%

100%
PF

80%
PF

% Imp.
Trise
+20

X
Trise
+20

R
Trise
+20

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

kVA

Weight

2

15

315

165

536

96.4

97.3

97.2

96.9

2.5

3.9

3.6

2.5

2.5

45

97.00

375

125

2

30

408

188

854

97.4

97.9

97.7

97.3

2.3

4.0

3.6

2.8

2.2

45

97.50

497

166

45

555

280

982

97.6

98.2

98.2

98.0

1.6

3.2

3.0

2.5

1.6

45

97.70

656

218

2

75

838

400

1289

97.8

98.4

98.5

98.4

1.3

3.0

2.9

2.6

1.2

50

98.00

1624

541

112.5

1367

550

1905

97.9

98.5

98.5

98.4

1.3

4.2

4.4

4.2

1.2

50

98.20

1171

390

2

150

1607

668

2474

98.2

98.6

98.6

98.4

1.4

4.6

4.7

4.5

1.2

50

98.30

1562

520

225

2582

850

3471

98.3

98.7

98.7

98.5

1.3

5.1

6.3

6.2

1.2

55

98.50

2159

719

300

3228

1100

3978

98.3

98.8

98.8

98.7

1.1

4.2

4.5

4.3

1.0

55

98.60

3255

1085

2

Total at
Rise +20

Full
Load

No
Load

2
2
2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-200

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Copper Wound

2
2

Type DS-3 150°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20°)

% Regulation

Inrush

kVA

Weight

No
Load

Total at
Rise +20

25%

50%

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

15

270

80

605

97.6

97.5

96.9

96.3

3.5

4.2

4.2

2.3

3.5

45

97.70

551

183

25

406

115

732

97.9

98.1

97.7

97.3

—

—

3.5

2.5

2.5

45

98.00

1379

459

37.5

453

125

1154

98.2

98.1

97.6

97.0

2.7

3.7

4.8

4.0

2.7

45

98.20

1321

440

50

657

160

1159

98.3

98.4

98.1

97.7

2.0

3.3

3.8

3.8

2.0

45

98.30

1321

440

75

803

175

2259

98.5

98.3

97.7

97.1

2.8

4.8

6.5

5.8

2.8

50

98.50

2133

711

100

960

250

2504

98.6

98.4

98.0

97.5

2.3

4.3

5.5

5.0

2.3

50

98.60

2779

926

167

1665

570

3094

98.7

98.8

98.6

98.3

1.5

6.3

9.0

8.8

1.5

50

98.70

2865

955

Efficiency (Trise +20°)

% Regulation

Inrush

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

98.1

97.8

97.3

2.4

2.2

3.3

Total at
Rise +20

25%

50%

2
2
2
2
2
2

Type DS-3 115°C Rise NEMA TP-1 Efficient
Losses in Watts

2

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

2.2

2.4

45

97.70

718

239

kVA

Weight

No
Load

15

264

80

437

97.8

25

420

110

603

97.9

98.2

98.0

97.7

2.0

2.9

3.2

2.6

2.0

45

98.00

862

287

37.5

450

125

1217

98.2

98.0

97.5

96.9

2.9

4.5

5.9

5.1

2.9

45

98.20

1300

433

50

703

300

1409

98.4

98.4

98.0

97.6

2.2

3.8

4.7

4.1

2.2

—

98.30

1498

499

75

793

175

2178

98.5

98.3

97.8

97.2

2.7

4.7

6.2

5.6

2.7

50

98.50

2107

702

2
2
2
2
2
2

Type DS-3 80°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20°)

% Regulation

Inrush

kVA

Weight

No
Load

Total at
Rise +20

25%

50%

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

15

407

115

293

97.3

98.2

98.3

98.2

1.2

1.7

1.8

1.4

1.2

45

97.70

375

125

25

430

300

679

97.9

98.4

98.3

98.1

1.5

2.6

3.0

2.6

1.5

45

98.00

494

164

37.5

685

300

729

98.1

98.6

98.6

98.5

1.1

2.2

2.6

2.3

1.1

45

98.20

617

205

50

799

180

1013

98.3

98.6

98.4

98.1

1.7

2.9

3.4

2.9

1.7

45

98.30

989

329

75

1042

250

1447

98.3

98.6

98.4

98.1

1.6

3.4

3.8

3.5

1.6

50

98.50

1015

338

2
2
2
2
2
2

Type DT-3 150°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20°)

Inrush

% Regulation

kVA

Weight

No
Load

Total at
Rise +20

25%

50%

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

15

250

150

755

98.9

97.0

96.4

95.7

4.2

5.3

4.8

2.6

4.0

45

97.00

321

107

30

350

165

1100

97.3

97.5

97.0

96.5

3.2

4.5

5.2

4.1

3.1

45

97.50

614

204

37.5

415

210

1382

97.5

97.6

97.1

96.5

3.2

4.8

4.0

2.5

3.1

45

97.70

639

213

45

416

215

1786

97.4

97.4

96.9

96.2

3.6

5.5

4.6

3.0

3.5

45

97.70

637

212

50

647

270

1220

97.7

98.2

98.0

97.7

2.0

3.5

2.8

2.0

1.9

45

98.00

1072

357

75

643

320

2903

97.9

97.5

97.1

96.4

3.6

7.4

4.3

2.5

3.4

50

98.00

1015

338

112.5

876

420

3699

97.9

97.9

97.4

96.8

3.0

6.7

5.1

4.2

2.9

50

98.20

1185

395

150

1064

530

4269

98.1

98.2

97.8

97.3

2.7

5.3

4.3

3.5

2.5

50

98.30

1752

584

225

1569

560

7124

98.4

98.1

97.5

97.0

3.2

8.7

7.4

6.8

2.9

55

98.50

2498

832

300

2050

730

7959

98.4

98.3

97.9

97.4

2.6

6.7

5.5

4.9

2.4

55

98.60

2872

964

500

3681

1400

8292

98.8

98.9

98.7

98.4

1.6

7.4

6.8

6.7

1.4

60

98.70

3839

1279

2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-201

2.6
2
2

Transformers
Transformer Standards, Technical Data and Accessories

Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Copper Wound
Type DT-3 115°C Rise NEMA TP-1 Efficient

2

Losses in Watts

% Regulation

Weight

15

256

95

669

97.7

97.8

97.3

96.7

4.0

5.4

4.8

2.9

3.8

45

97.00

229

76

2

30

337

180

1077

97.7

97.8

97.3

96.8

3.0

6.2

4.6

3.5

3.0

45

97.50

433

144

2

45

446

215

1625

97.7

97.7

97.2

96.6

3.2

5.2

4.4

3.1

3.1

45

97.70

658

219

50

630

270

1213

97.8

98.2

98.0

97.7

2.0

3.5

3.0

2.3

1.9

45

98.00

960

320

2

75

662

320

2346

97.9

98.0

97.6

97.0

2.8

5.4

4.7

3.9

2.7

50

98.00

842

280

112.5

914

400

2953

98.1

98.2

97.9

97.4

2.5

5.7

5.0

4.5

2.3

50

98.20

1036

345

2

150

1132

530

3364

98.3

98.5

98.2

97.8

2.0

4.8

4.4

4.0

1.9

50

98.30

1605

535

225

2036

650

6445

98.4

98.3

97.8

97.3

2.9

8.8

8.1

7.7

2.6

55

98.50

1572

524

300

2325

830

6038

98.6

98.7

98.4

98.1

2.0

5.7

5.2

4.9

1.7

55

98.60

1860

620

500

3681

1400

7841

98.8

98.9

98.7

98.5

1.4

6.8

6.8

6.6

1.3

60

98.70

4033

1344

TP1
Efficiency

Absolute
Max.

Practical
Max.
150

2
2
2
2

25%

50%

75%

Full
Load

100%
PF

80%
PF

Inrush

kVA

2

Total at
Rise +20

Efficiency (Trise +20°)

No
Load

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

Type DT-3 80°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20°)
75%

80%
PF

%
Imp.

X

R

Sound
Level dB

15

349

135

390

96.6

97.7

97.7

97.6

1.8

2.4

2.1

1.3

1.7

45

97.00

449

2

30

410

210

823

97.3

97.9

97.7

97.4

2.1

3.4

3.0

2.1

2.0

45

97.50

493

164

45

504

200

1308

97.9

98.0

97.7

97.2

2.5

4.5

3.9

3.1

2.5

45

97.70

473

158

2

75

818

370

1837

97.9

98.2

98.0

97.7

2.0

9.3

4.3

3.8

2.0

50

98.00

937

312

112.5

1065

440

2409

98.1

98.3

98.0

97.6

1.8

3.8

3.3

2.8

1.8

50

98.20

1754

584

2

150

1410

650

3349

98.3

98.5

98.3

97.9

1.9

3.9

3.7

3.2

1.8

50

98.30

1593

531

2

225

2030

830

4096

98.4

98.7

98.5

98.3

1.6

5.4

5.4

5.2

1.5

55

98.50

2568

856

300

3041

1100

4646

98.5

98.8

98.7

98.5

1.4

5.6

6.1

6.0

1.2

55

98.60

3753

1251

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

2

50%

Inrush

100%
PF

Weight

2

25%

% Regulation

kVA

2

Total at
Rise +20

Full
Load

No
Load

Type KT-4 80°C Rise NEMA TP-1 Efficient
Losses in Watts

% Regulation

2

15

251

100

635

96.8

97.1

96.6

96.0

3.7

5.0

4.2

2.1

3.6

45

97.00

265

88

30

326

165

1134

97.4

97.5

97.1

96.5

3.5

5.3

4.3

2.9

3.2

45

97.50

504

168

2

45

479

220

1505

97.6

97.8

97.3

96.8

3.0

5.6

5.0

4.1

2.9

45

97.70

670

223

75

463

300

2883

97.9

97.7

97.1

96.4

3.6

7.1

5.9

4.7

3.4

50

98.00

975

325

2

112.5

977

440

2952

98.1

98.2

97.9

97.5

2.6

6.6

5.6

5.1

2.2

50

98.20

1031

344

2

150

1212

540

3716

98.3

98.4

98.0

97.6

2.4

6.0

5.1

4.6

2.1

50

98.30

1574

524

225

1815

650

5420

98.4

98.5

98.1

97.7

2.4

7.6

6.5

6.2

2.1

55

98.50

1694

565

2

300

2400

830

6259

98.6

98.6

98.4

98.0

2.2

6.3

5.2

4.9

1.8

55

98.60

2594

864

50%

75%

100%
PF

80%
PF

Inrush

Weight

25%

Full
Load

%
Imp.

kVA

2

Total at
Rise +20

Efficiency (Trise +20°)

No
Load

X

2
2
2
2
2
V2-T2-202

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Practical
Max.

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Copper Wound

2
2

Type KT-4 115°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20°)

% Regulation

Inrush

kVA

Weight

No
Load

Total at
Rise +20

25%

50%

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

15

256

95

702

96.7

96.9

96.3

95.6

4.2

5.7

5.0

2.9

4.0

45

97.00

279

93

30

341

165

1007

97.4

97.6

97.3

96.8

3.0

4.8

4.2

3.1

2.8

45

97.50

466

155

45

526

220

1200

97.9

98.1

97.9

97.5

2.3

5.0

4.1

3.5

2.2

50

97.70

633

211

75

759

300

1715

98.1

98.3

98.1

97.8

1.9

5.0

4.5

4.1

1.9

50

98.00

929

309

112.5

1030

470

2735

98.0

98.3

98.0

97.7

2.2

4.4

3.8

3.2

2.0

50

98.20

1171

390

150

1631

650

3076

98.2

98.5

98.3

98.1

1.7

4.9

4.5

4.2

1.6

50

98.30

1250

416

225

1965

690

4434

98.5

98.6

98.4

98.1

1.9

5.6

5.3

5.0

1.7

55

98.50

1979

659

300

2337

830

6127

98.6

98.7

98.4

98.0

2.0

5.2

4.7

4.3

1.8

55

98.60

2187

729

2
2
2
2
2
2
2
2

Type KT-4 80°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20°)

% Regulation

Inrush

kVA

Weight

No
Load

Total at
Rise +20

25%

50%

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

2

15

365

165

371

97.0

98.0

98.1

98.0

1.5

2.3

2.1

1.5

1.4

45

97.00

499

166

30

424

210

787

97.3

97.9

97.8

97.6

2.0

3.2

2.9

2.2

1.9

45

97.50

659

219

2

45

653

290

977

97.4

98.1

98.1

98.0

1.6

3.1

3.0

2.5

1.5

45

97.70

925

308

75

640

350

1951

97.8

98.1

97.8

97.5

2.2

5.2

4.9

4.4

2.1

50

98.00

854

284

112.5

1264

560

2009

98.2

98.7

98.6

98.4

1.4

4.3

4.2

4.0

1.3

50

98.20

1449

483

150

1825

650

2873

98.5

98.7

98.5

98.2

1.6

6.1

6.4

6.3

1.5

50

98.30

1288

429

225

2096

890

4449

98.3

98.6

98.4

98.1

1.8

6.5

6.6

6.4

1.6

55

98.50

2292

764

2
2
2
2
2

Type KT-13 150°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20°)

% Regulation

Inrush

kVA

Weight

No
Load

Total at
Rise +20

25%

50%

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

2

15

346

165

461

96.2

97.4

97.5

97.3

2.1

3.0

2.5

1.6

2.0

45

97.00

527

176

30

390

190

908

97.2

97.7

97.5

97.1

2.6

4.0

3.3

2.3

2.4

45

97.50

579

193

2

45

623

235

1328

97.6

97.9

97.6

97.2

2.5

3.2

2.8

1.4

2.4

45

97.70

854

285

75

848

370

2402

97.7

97.9

97.5

97.0

2.8

5.7

4.5

3.6

2.7

50

98.00

1046

348

112.5

1080

455

2991

98.0

98.2

97.9

97.4

2.4

4.3

3.5

2.7

2.3

50

98.20

1180

393

150

1431

600

3686

98.2

98.3

98.1

97.7

2.3

5.1

4.2

3.7

2.1

50

98.30

1250

416

225

2129

830

4250

98.4

98.6

98.4

98.2

2.0

6.3

5.4

5.1

1.5

55

98.50

2771

923

2
2
2
2
2

Type KT-13 115°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20°)

% Regulation

Inrush

kVA

Weight

No
Load

Total at
Rise +20

25%

50%

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

2

15

341

165

378

96.6

97.8

97.9

97.9

1.5

2.4

2.1

1.6

1.4

45

97.00

472

157

30

444

188

824

97.1

97.8

97.6

97.3

2.2

3.6

3.1

2.2

2.1

45

97.50

620

206

2

45

598

250

1476

97.4

97.7

97.4

96.9

2.8

4.6

4.0

2.9

2.7

45

97.70

939

313

75

894

350

2128

97.9

98.1

97.9

97.5

1.9

5.1

4.6

4.0

2.4

50

98.00

847

282

112.5

1054

460

2612

98.1

98.3

98.1

97.8

2.0

4.3

3.3

2.6

1.9

50

98.20

1375

458

150

1399

600

3185

98.2

98.5

98.3

98.0

2.0

5.9

5.4

5.1

1.7

50

98.30

1379

460

225

2088

890

4382

98.3

98.6

98.4

98.2

1.8

6.1

5.7

5.5

1.6

55

98.50

2490

830

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-203

2
2
2
2

2.6
2
2

Transformers
Transformer Standards, Technical Data and Accessories

Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Copper Wound
Type KT-13 80°C Rise NEMA TP-1 Efficient

2

Losses in Watts

Efficiency (Trise +20°)

Weight

15

370

165

382

96.7

97.8

97.9

97.8

1.5

2.4

2.2

1.6

1.4

45

97.00

472

2

30

490

188

595

97.4

98.2

98.2

98.1

1.4

3.0

2.8

2.5

1.4

45

97.50

592

197

2

45

635

290

1189

97.4

97.9

97.8

97.5

2.1

3.9

3.5

2.8

2.0

45

97.70

736

245

75

987

410

1351

97.7

98.9

98.4

98.3

1.4

2.8

2.6

2.3

1.3

50

98.00

1590

530

2

112.5

854

560

2039

98.1

98.6

98.5

98.3

1.4

4.2

4.3

4.1

1.3

50

98.20

1374

458

150

1807

650

3053

98.0

98.4

98.3

98.0

1.7

4.3

4.0

3.7

1.6

50

98.30

1472

490

2

225

4091

1200

2364

98.2

98.9

99.1

99.1

0.6

2.7

2.9

2.8

0.5

55

98.50

4321

1440

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

2

25%

50%

Inrush

kVA

2

Total at
Rise +20

% Regulation

No
Load

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.
157

Type KT-13 115°C Rise E3 Efficient

2

Losses in Watts
No
Load

Total at
Rise +20

Efficiency (Trise +20°)

% Regulation
Full
Load

100%
PF

80%
PF

Inrush
%
Imp.

Practical
Max.

kVA

Weight

15

3.25

78

359

97.6

98.1

98.0

97.7

2.0

3.7

3.2

2.6

1.9

45

98.00

307

102

2

30

370

125

636

98.1

98.4

98.3

98.0

1.7

2.7

2.3

1.6

1.7

45

98.30

779

260

2

45

635

135

1076

98.5

98.5

98.1

97.7

2.2

4.1

3.5

2.8

2.1

45

98.50

617

206

75

870

225

1529

98.5

98.6

98.4

98.0

1.9

4.9

4.4

4.1

1.7

50

98.60

993

331

2

112.5

1526

350

1768

98.6

98.8

98.7

98.5

1.3

3.5

3.1

2.8

1.3

50

98.80

2447

816

150

1665

350

2419

97.8

98.9

98.7

98.4

1.5

4.5

4.2

3.9

1.4

50

98.90

1976

659

2

225

2094

650

3650

98.9

98.9

98.8

98.5

1.5

5.4

5.2

5.1

1.3

55

99.00

2686

895

300

3900

750

3731

98.9

99.1

99.0

98.8

1.3

5.2

5.2

5.1

1.0

55

99.04

2990

997

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

2

25%

50%

75%

X

2
2

Type KT-9 115°C Rise E3 Efficient

2

Losses in Watts
Total at
Rise +20

Efficiency (Trise +20°)

Inrush

% Regulation

kVA

Weight

No
Load

2

15

335

78

353

97.4

98.0

98.0

97.7

2.0

3.7

3.2

2.6

1.8

45

98.00

287

96

2

30

406

125

670

98.0

98.3

98.1

97.8

1.9

2.7

2.4

1.5

1.8

45

98.30

780

260

45

635

135

1075

98.6

98.5

98.2

97.7

2.3

4.1

3.5

2.8

2.1

45

98.50

603

201

2

75

870

210

1551

98.5

98.6

98.3

98.0

1.9

4.0

3.6

3.1

1.8

50

98.60

958

319

112.5

1526

350

1583

98.6

98.9

98.8

98.6

1.2

3.0

2.7

2.5

1.1

50

98.80

2480

827

2

150

1665

350

2463

98.8

98.9

98.7

98.4

1.6

4.5

4.2

4.0

1.4

50

98.90

1930

643

225

2094

650

3766

98.8

98.9

98.7

98.4

1.7

5.5

5.2

5.0

1.4

55

99.00

2778

926

25%

50%

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

2
2
2
2
2
2
2
2
V2-T2-204

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Practical
Max.

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Typical Data for 600-Volt Class General-Purpose Dry-Type Transformers, Copper Wound

2
2

Type NON HMT 115°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20°)

% Regulation

Inrush

kVA

Weight

No
Load

Total at
Rise +20

25%

50%

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

15

362

80

527

97.6

97.7

97.3

96.7

3.2

5.9

5.1

4.2

3.0

45

97.00

—

—

30

430

100

1040

98.3

98.0

97.4

96.7

3.2

6.2

5.4

4.4

3.1

45

97.50

—

—

45

627

170

1368

98.3

98.2

97.7

97.2

2.8

6.0

5.2

4.4

2.7

45

97.70

—

—

75

926

250

2096

98.4

98.3

97.9

97.4

2.6

7.0

6.2

5.7

2.5

50

98.00

—

—

112.5

1628

400

2515

98.4

98.5

98.3

97.9

2.0

5.5

4.9

4.5

1.9

50

98.20

—

—

150

2001

500

2688

98.5

98.7

98.6

98.3

1.6

5.6

5.2

5.0

1.5

50

98.30

—

—

225

3596

590

3310

98.8

98.9

98.8

98.6

1.5

6.2

6.0

5.9

1.2

55

98.50

—

—

300

3891

800

4854

98.7

98.9

98.7

98.4

1.7

7.1

7.0

6.8

1.4

55

98.60

—

—

2
2
2
2
2
2
2
2

Type THR HMT 115°C Rise NEMA TP-1 Efficient
Losses in Watts

Efficiency (Trise +20°)

% Regulation

Inrush

kVA

Weight

No
Load

Total at
Rise +20

25%

50%

75%

Full
Load

100%
PF

80%
PF

%
Imp.

X

R

Sound
Level dB

TP1
Efficiency

Absolute
Max.

Practical
Max.

2

15

—

80

708

97.1

97.0

96.4

95.5

4.3

7.4

6.3

4.7

4.2

45

97.00

—

—

30

450

100

1409

98.0

97.4

96.5

95.6

4.7

8.0

6.8

5.2

4.4

45

97.50

—

—

2

45

610

170

1374

98.2

98.1

97.7

97.1

2.8

4.8

4.2

3.2

2.7

45

97.70

—

—

75

868

250

2341

98.2

98.1

97.6

97.0

2.9

6.6

5.8

5.0

2.8

50

98.00

—

—

112.5

1643

400

2685

98.3

98.4

98.1

97.7

2.2

5.5

5.0

4.6

2.0

50

98.20

—

—

150

—

500

3304

98.5

98.6

98.3

97.9

2.0

6.7

6.3

6.0

1.9

50

98.30

—

—

225

3370

590

3712

98.7

98.8

98.7

98.4

1.7

6.6

6.4

6.2

1.4

55

98.50

—

—

300

3894

800

4688

98.9

99.0

98.8

98.5

1.7

7.4

7.2

7.1

1.3

55

98.60

—

—

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-205

2.6
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

2

Transformer Standards, Technical Data and Accessories

Typical Specifications—
General-Purpose (1000 kVA and Below)
General
Furnish and install, singlephase and three-phase
general-purpose individually
mounted dry-type
transformers of the twowinding type, self-cooled,
with ratings and voltages as
indicated on the drawings.
Transformers shall be
manufactured by Eaton.
Transformers shall be
designed, manufactured and
tested in accordance with all
the latest applicable ANSI,
NEMA and IEEE Standards. All
600-volt class transformers
through 1000 kVA shall be UL
listed and bear the UL label.
Transformers shall be
designed for continuous
operation at rated kVA, for
operation 24 hours a day,
365 days a year, with normal
life expectancy as defined in
ANSI C57.96.
Insulation Systems
Transformers shall be
insulated as follows:
●

2
2

Transformers

●

Type EP or EPT:
0.050 through 75 kVA:
180°C insulation system
Type DS-3 or DT-3:
15 kVA and above: 220°C
insulation system

Required performance
shall be obtained without
exceeding the above
indicated temperature
rise in a 40°C maximum
ambient, with a 30°C average
over 24 hours.

Core and Coil Assemblies
Transformer core shall be
constructed with high-grade,
non-aging, silicon steel with
high magnetic permeability,
and low hysteresis and eddy
current losses. Maximum
magnetic flux densities
shall be substantially below
the saturation point. The
transformer core volume shall
allow efficient transformer
operation at 10% above the
nominal tap voltage. The core
laminations shall be tightly
clamped and compressed.
Coils shall be wound of
electrical-grade [aluminum]
[copper] and continuous
wound construction. BIL
(basic impulse level) for all
600-volt class windings shall
be 10 kV.
On encapsulated units
rated [75 kVA and below]
[15 kVA and below] [9 kVA
and below], the core and
coil assembly shall be
completely encapsulated
in a proportioned mixture of
resin or epoxy and aggregate
to provide a moisture-proof,
shock-resistant seal. The
core and coil encapsulation
system shall minimize the
sound level.
On ventilated units rated
[15 kVA and above] [30 kVA
and above] [112.5 kVA
and above], the core and
coil assembly shall be
installed on vibrationabsorbing pads.

Enclosures
The enclosure shall be made
of heavy-gauge steel and
shall be finished using a
continuous process of
degreasing, cleaning and
phosphatizing, followed by
electrostatic deposition of
a thermosetting polyester
powder coating and
subsequent baking. The
coating color shall be ANSI 61
and shall be UL recognized
for outdoor use. The
maximum temperature
on top of the enclosure
shall not exceed 90°C.

suitable weathershields over
ventilation openings. To
ensure proper ventilation,
locate the unit at least 6
inches (152.4 mm) from the
adjacent wall or structure.
Tests
The following tests shall be
performed as standard on all
transformers:
1. Ratio tests at the rated
voltage connection and
at all tap connections.
2. Polarity and phase
relation tests on the
rated voltage connection.

On units rated [75 kVA
and below] [15 kVA and
below] [9 kVA and below]
encapsulated, the enclosure
construction shall be totally
enclosed, non-ventilated,
NEMA 3R, with lifting
provisions.

3. Applied potential tests.
4. Induced potential test.
5. No-load and excitation
current at rated voltage
on the rated voltage
connection.

On units rated [15 kVA and
above] [30 kVA and above]
[112.5 kVA and above], the
enclosure construction shall
be ventilated, NEMA 2, dripproof, with lifting provisions.
All ventilation openings shall
be protected against falling
dirt. On outdoor units, provide

Sound Levels
Transformer average sound
levels shall not exceed the
following ANSI and NEMA
levels for self-cooled ratings
measured in accordance with
NEMA ST-20.

Average Sound Levels
NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

Encapsulated
(up to 1.2 kV)

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

50.01 to 75.00

50

53

55

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

2

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

2

500.01 to 700.00

62

65

61

2

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

2
2
2
2
2
2

All insulation materials shall
be flame-retardant and shall
not support combustion as
defined in ASTM Standard
Test Method D635.

2
2
V2-T2-206

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Typical Specifications—
Dry-Type Transformers for Nonlinear Loads
General
Furnish and install,
individually mounted dry-type
transformers of the twowinding type, self-cooled,
with ratings and voltages as
indicated on the drawings.
Transformers shall be
manufactured by Eaton.
Transformers shall be
designed, manufactured
and tested in accordance with
all the latest applicable ANSI,
NEMA and IEEE Standards.
All 600-volt class
transformers through 500
kVA shall be UL listed
as suitable for non-sinusoidal
current loads with K factor
not to exceed [4] [13] [20].
Insulation Systems
Transformers shall be
insulated with a UL
recognized 220°C
insulation system. Winding
temperature rise shall be
[80°C] [115°C] [150°C].
Required performance
shall be obtained without
exceeding the above
indicated temperature rise in
a 40°C maximum ambient,
with a 30°C average.
All insulation materials shall
be flame-retardant and shall
not support combustion as
defined in ASTM Standard
Test Method D635.

2

Core and Coil Assemblies
Transformer core shall be
constructed with high-grade,
non-aging, silicon steel with
high magnetic permeability,
and low hysteresis and eddy
current losses. Maximum
magnetic flux densities
shall be substantially below
the saturation point. The
transformer core volume shall
allow efficient transformer
operation at 10% above the
nominal tap voltage. The core
laminations shall be tightly
clamped and compressed.

Enclosures
The enclosure shall be made
of heavy gauge steel and
shall be finished utilizing a
continuous process of
degreasing, cleaning and
phosphatizing, followed by
electrostatic deposition of a
polymer polyester powder
coating and baking. The
coating color shall be ANSI 61
and shall be UL recognized
for outdoor use. The
maximum temperature
on top of the enclosure
shall not exceed 90°C.

Transformer coils shall be
wound of electrical-grade
[aluminum] [copper]
conductor with continuous
wound construction. An
electrostatic shield consisting
of a single turn of aluminum
shall be placed between the
primary and secondary
winding and grounded to the
transformer core. BIL (basic
impulse level) for all 600-volt
class windings shall be 10 kV.

The enclosure construction
shall be ventilated, NEMA 2,
drip-proof, with lifting
provisions. All ventilation
openings shall be protected
against falling dirt. On
outdoor units, provide
suitable weathershields
over ventilation openings. To
ensure proper ventilation,
locate the unit at least 6
inches (152.4 mm) from the
adjacent wall or structure.

The core and coil assembly
shall be installed on vibrationabsorbing pads.

Nonlinear Ratings
The transformers shall be
specifically designed to
supply circuits with a
harmonic profile equal to or
less than a K-factor of 4 or 13
as described below without
exceeding [80°C] [115°C]
[150°C] temperature rise.

The neutral conductor shall
be rated to carry 200% of
normal phase current.

2

Nonlinear Ratings
Harmonic

K-4

K-13

Fundamental

100.0%

100.0%

3rd

34.0%

70.0%

5th

22.0%

42.0%

7th

3.0%

5.0%

9th

1.0%

3.0%

11th

0.7%

3.0%

13th

0.5%

1.0%

15th

0.3%

0.7%

17th

0.3%

0.6%

Tests
The following tests shall be
performed as standard on all
transformers:
1. Ratio tests at the rated
voltage connection and
at all tap connections.
2. Polarity and phase
relation tests on the
rated voltage connection.
3. Applied potential tests.
4. Induced potential test.
5. No-load and excitation
current at rated voltage
on the rated voltage
connection.
Sound Levels
Transformer average sound
levels shall not exceed the
following ANSI and NEMA
levels for self-cooled ratings
measured in accordance with
NEMA ST-20.

Average Sound Levels

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

Encapsulated
(up to 1.2 kV)

2

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

2

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

50.01 to 75.00

50

53

55

2
2
2

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

500.01 to 700.00

62

65

61

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2
2
2

V2-T2-207

2

2.6
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Transformers
Transformer Standards, Technical Data and Accessories

Typical Specification—
AC Adjustable Frequency Drive Isolation Transformers
General
Furnish and install, singlephase and three-phase
general-purpose individually
mounted dry-type
transformers of the twowinding type, self-cooled,
with ratings and voltages
for input application as
indicated on the drawings.
Transformers shall be
manufactured by Eaton.
Transformers shall be
designed, manufactured and
tested in accordance with all
the latest applicable ANSI,
NEMA and IEEE Standards. All
600-volt class transformers
through 550 kVA shall be UL
listed and bear the UL label.
Transformers shall be
designed for continuous
operation at rated kVA, for
operation 24 hours a day,
365 days a year, with normal
life expectancy as defined in
ANSI C57.96.
Insulation Systems
Transformers shall be
insulated with a UL
recognized 220°C
insulation system.
Required performance
shall be obtained without
exceeding the above
indicated temperature rise
in a 40°C maximum ambient,
with a 30°C average over
24 hours.
All insulation materials shall
be flame-retardant and shall
not support combustion as
defined in ASTM Standard
Test Method D635.

Core and Coil Assemblies
Transformer core shall be
constructed with high-grade,
non-aging, silicon steel with
high magnetic permeability,
and low hysteresis and eddy
current losses. Maximum
magnetic flux densities shall
be substantially below the
saturation point. The
transformer core volume shall
allow efficient transformer
operation at 10% above the
nominal tap voltage. The core
laminations shall be tightly
clamped and compressed.
Coils shall be wound of
electrical-grade [aluminum]
[copper] and continuous
wound construction. BIL
(basic impulse level) for all
600-volt class windings shall
be 10 kV.
A temperature sensing
device shall be imbedded
in the center coil.
The core and coil assembly
shall be installed on vibrationabsorbing pads.

Enclosures
The enclosure shall be made
of heavy-gauge steel and
shall be finished using a
continuous process of
degreasing, cleaning, and
phosphatizing, followed by
electrostatic deposition of
a thermosetting polyester
powder coating and
subsequent baking. The
coating color shall be ANSI 61
and shall be UL recognized
for outdoor use. The
maximum temperature on
top of the enclosure shall
not exceed 90°C.

The following table lists
the recommended kVA
size of the drive isolation
transformer for a specific
horsepower requirement.
Three-Phase

The enclosure construction
shall be ventilated, NEMA 2,
drip-proof, with lifting
provisions. All ventilation
openings shall be protected
against falling dirt. To ensure
proper ventilation, locate
the unit at least 6 inches
(152.4 mm) from the
adjacent wall or structure.
On outdoor units, provide
suitable weathershields
over ventilation openings.
Sound Levels
Transformer average sound
levels shall not exceed the
following ANSI and NEMA
levels for self-cooled ratings
measured in accordance with
NEMA ST-20.

Horsepower
AC Motor

kVA
Minimum

5

7.5

7.5

11

10

14

15

20

20

27

25

34

30

40

40

51

50

63

60

75

75

93

100

118

125

145

150

175

200

220

250

275

300

330

400

440

500

550

600

660

700

770

Average Sound Levels
NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

Encapsulated
(up to 1.2 kV)

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

9.01 to 15.00

45

45

50

2

15.01 to 30.00

45

45

50

2

30.01 to 50.00

45

48

50

50.01 to 75.00

50

53

55

2

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

2

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

2

300.01 to 500.00

60

63

59

2

500.01 to 700.00

62

65

61

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

2
V2-T2-208

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.6

Transformers
Transformer Standards, Technical Data and Accessories

Typical Specifications—
Mini–Power Centers (3–30 kVA)
General
Furnish and install, singlephase and three-phase
general-purpose individually
mounted mini–power centers
of the two-winding type,
self-cooled, with ratings
and voltages as indicated
on the drawings. Mini–
power centers shall be
manufactured by Eaton.
Units shall be designed,
manufactured and tested in
accordance with all the latest
applicable ANSI, NEMA,
IEEE, CSA and UL standards,
and shall be UL listed and
CSA certified and bear the
UL and CSA labels.
Units shall be designed for
continuous operation at
rated kVA, 24 hours a day,
365 days a year, with normal
life expectancy as defined in
ANSI C57.96.
Each mini–power center shall
include a main primary breaker
with an interrupting rating
of 14 kA at 277/480 volts;
an encapsulated dry-type
transformer and a secondary
panelboard with main breaker
rated 10 kA interrupting rating
at 120/240 volts.

2
1. All interconnecting wiring
between the primary
breaker and transformer,
secondary main breaker
and transformer, and
distribution section shall
be factory installed. Main
primary, secondary and
feeder breakers shall
be enclosed with a
padlockable hinged door.
2. The secondary
distribution section shall
accommodate one-inch,
plug-in breakers with
10 kA interrupting
capacity.
3. On the all-copper, bolt-on
designs, the secondary
distribution section shall
accommodate bolt-on
breakers with 10 kA
interrupting capacity.
Insulation System
Transformers shall be
insulated with a 180°C
insulation system.
Required performance
shall be obtained without
exceeding the above
indicated temperature rise
in a 40°C maximum ambient,
with a 30°C average over
24 hours.
All insulation materials shall
be flame-retardant and shall
not support combustion as
defined in ASTM Standard
Test Method D635.

Core and Coil Assemblies
Transformer core shall be
constructed with high-grade,
non-aging, silicon steel with
high magnetic permeability,
and low hysteresis and eddy
current losses. Maximum
magnetic flux densities shall
be substantially below the
saturation point.
The transformer core
volume shall allow efficient
transformer operation at
10% above the nominal tap
voltage. The core laminations
shall be tightly clamped and
compressed. Coils shall be
wound of electrical-grade
aluminum (copper) with
continuous wound
construction. BIL (basic
impulse level) for all 600-volt
class windings shall be 10 kV.
The core and coil assembly
shall be completely
encapsulated in a
proportioned mixture
of resin or expoxy and
aggregate to provide a
moisture-proof, shockresistant seal. The core
and coil encapsulation
system shall minimize the
sound level.
Enclosures
The enclosure shall be made
of heavy-gauge steel and
shall be finished using a
continuous process of
degreasing, cleaning, and
phosphatizing, followed by
electrostatic deposition of
a thermosetting polymer
polyester powder coating
and subsequent baking. The
coating color shall be ANSI 61
and shall be UL recognized
for outdoor use. Mini–power
centers shall be equipped
with a wiring compartment
suitable for conduit entry
and large enough to allow
convenient wiring. The
maximum temperature on
top of the enclosure shall
not exceed 90°C. The core
of the transformer shall be
grounded to the enclosure.
The enclosure shall be totally
enclosed, non-ventilated,
NEMA 3R, with lifting eyes.

Tests
The following tests shall be
performed as standard on all
transformers:
1. Ratio tests at the rated
voltage connection and
at all tap connections.
2. Polarity and phase
relation tests on the
rated voltage connection.
3. Applied potential tests.
4. Induced potential test.
5. No-load and excitation
current at rated voltage
on the rated voltage
connection.
Sound Levels
Transformer average sound
levels shall not exceed the
following ANSI/NEMA levels
for self-cooled ratings
measured in accordance
with NEMA ST-20.
Average Sound Levels 1
kVA

NEMA Average
Sound Level in dB

0–9

45

10–30

50

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
1 Currently being reviewed and revised
by NEMA.

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2

2
2
2
2
2
2
2
2
2
2
2
2
2

V2-T2-209

2.6
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Transformers
Transformer Standards, Technical Data and Accessories

Typical Specification—
NEMA TP-1-2002 Compliant Energy-Efficient Transformers
General
Furnish and install, threephase energy-efficient
dry-type transformers that
comply with NEMA Standard
TP-1-2002 and U.S. DOE
10 CFR Parts 430 and 431.
Transformers shall be of the
two-winding type, selfcooled, with ratings (kVA) as
indicated on the drawings.
Transformer’s losses shall
conform to NEMA TP-1
requirements. Transformers
shall be manufactured
by Eaton.
Transformers shall be
designed, manufactured and
tested in accordance with all
the latest applicable ANSI,
NEMA and IEEE Standards,
and shall be listed by
Underwriters Laboratories
and bear the UL label.
Transformers shall be
designed for continuous
operation at rated kVA, for
24 hours a day, 365 days
a year, with normal life
expectancy as defined in
ANSI C57.96.
Insulation System and
Temperature Rise
Transformers shall be
insulated with a 220°C
insulation system.
Transformers shall be
150°C rise and shall be
capable of carrying a 15%
continuous overload without
exceeding a 150°C rise.
Required performance
shall be obtained without
exceeding the above rise
in a 40°C maximum,
30°C average ambient
temperature.
All insulation materials shall
be flame-retardant and shall
not support combustion as
defined in ASTM Standard
Test Method D635.

2
2
2
2
V2-T2-210

Core and Coil Assemblies
Transformer core shall be
constructed with high-grade,
non-aging, silicon steel with
high magnetic permeability,
and low hysteresis and eddy
current losses. Maximum
magnetic flux densities
shall be substantially below
the saturation point.
The transformer core
volume shall allow efficient
transformer operation at
10% above the nominal tap
voltage. The core laminations
shall be tightly clamped and
compressed. Coils shall be
wound of electrical grade
[aluminum] [copper] and
continuous wound
construction. BIL (basic
impulse level) for all 600-volt
class windings shall be 10 kV.
The core and coil assembly
shall be installed on vibrationabsorbing pads.
Enclosures
The enclosure shall be made
of heavy gauge steel and
shall be finished utilizing a
continuous process of
degreasing, cleaning and
phosphatizing, followed by
electrostatic deposition of
a thermosetting polyester
powder coating and
subsequent baking. The
coating color shall be ANSI 61
and shall be UL recognized
for outdoor use.
The enclosure construction
shall be ventilated, NEMA 2,
drip-proof, with lifting
provisions. All ventilation
openings shall be protected
against falling dirt. To ensure
proper ventilation, locate
the unit at least 6 inches
(152.4 mm) from the
adjacent wall or structure.
All transformers shall be
equipped with a wiring
compartment suitable for
conduit entry and large
enough to allow convenient
wiring. The maximum
temperature on top of
the enclosure shall not
exceed 90°C.

Tests
The following tests shall be
performed as standard on all
transformers:
1. Ratio tests at the rated
voltage connection and
at all tap connections.
2. Polarity and phase
relation tests on the
rated voltage connection.
3. Applied potential tests.
4. Induced potential test.

5. No-load and excitation
current at rated voltage
on the rated voltage
connection.
Efficiency
Transformers shall be
energy-efficient with
minimum efficiencies as set
forth per NEMA TP-1-2002
and U.S. DOE 10 CFR Parts
430 and 431 when operated
at 35% of full load capacity.

NEMA TP-1-2002 Efficiency Levels
Tables of Energy Efficiency
NEMA Class 1 Efficiency Levels
Dry-Type Distribution Transformers—Low Voltage (600 V and below)
Single-Phase

Three-Phase

kVA

Efficiency

kVA

Efficiency

15

97.7

15

97.0

25

98.0

30

97.5

37.5

98.2

45

97.7

50

98.3

75

98.0

75

98.5

112.5

98.2

100

98.6

150

98.3

167

98.7

225

98.5

250

98.8

300

98.6

333

98.9

500

98.7

—

—

750

98.8

—

—

1000

98.9

Sound Levels
Transformer average sound
levels shall not exceed the
following ANSI and NEMA
levels for self-cooled ratings.
Average Sound Levels
NEMA ST-20 Average Sound Level, dB
Equivalent Winding Self-Cooled Ventilated (up to 1.2 kV)
kVA Range
K-Factor 1, 4, 9
K-Factor 13, 20

Encapsulated
(up to 1.2 kV)

3.00 and below

40

40

45

3.01 to 9.00

40

40

45

9.01 to 15.00

45

45

50

15.01 to 30.00

45

45

50

30.01 to 50.00

45

48

50

50.01 to 75.00

50

53

55

75.01 to 112.50

50

53

55

112.51 to 150.00

50

53

55

150.01 to 225.00

55

58

57

225.01 to 300.00

55

58

57

300.01 to 500.00

60

63

59

500.01 to 700.00

62

65

61

700.01 to 1000.00

64

67

63

Greater than 1000

Consult factory

Consult factory

Consult factory

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Transformer Standards, Technical Data and Accessories

2.6

Glossary of Transformer Terms
Air cooled: A transformer
that is cooled by the natural
circulation of air around, or
through, the core and coils.
Ambient noise level: The
existing or inherent sound
level of the area surrounding
the transformer, prior to
energizing the transformer.
Measured in decibels.
Ambient temperature:
The temperature of the air
surrounding the transformer
into which the heat of the
transformer is dissipated.
Ampacity: The currentcarrying capacity of an
electrical conductor under
stated thermal conditions.
Expressed in amperes.
Ampere: The practical unit
of electric current.
Attenuation: A decrease
in signal power or voltage.
Unit of measure is dB.
Autotransformer:
A transformer in which part
of the winding is common
to both the primary and the
secondary circuits.
Banked: Two or more singlephase transformers wired
together to supply a threephase load. Three singlephase transformers can be
“banked” together to support
a three-phase load. For
example, three 10 kVA singlephase transformers “banked”
together will have a 30 kVA
three-phase capacity.
BIL: Basic impulse level.
The ability of a transformer’s
insulation system to
withstand high voltage
surges. All Eaton 600V-class
transformers have a 10 kV
BIL rating.
BTU: British thermal unit.
In North America, the term
“BTU” is used to describe
the heat value (energy
content) of fuels, and also
to describe the power of
heating and cooling systems,
such as furnaces, stoves,
barbecue grills and air
conditioners. When used
as a unit of power, BTU
“per hour” (BTU/h)

is understood, though this
is often abbreviated to
just “BTU.”
Buck-boost: The name
of a standard, single-phase,
two-winding transformer
application with the low
voltage secondary windings
connected as an
autotransformer for boosting
(increasing) or bucking
(decreasing) voltages in small
amounts. Applications can
either be single-phase or
three-phase.
CE: Mark to indicate thirdparty approved or selfcertification to specific
requirements of the
European community.
Celsius (centigrade): Metric
temperature measure.
°F = (1.8 x °C) + 32
°C = (°F-32) / 1.8
Center tap: A tap at the midpoint of a winding. The center
tap on three-phase delta-delta
transformers is called a
lighting tap. It provides 5%
of the transformer’s kVA for
single-phase loads.
Certified tests: Actual values
taken during production tests
and certified as applying to a
given unit shipped on a
specific order. Certified tests
are serial number–specific.
Common mode: Electrical
noise or voltage fluctuation
that occurs between all of the
line leads and the common
ground, or between ground
and line or neutral.
Compensated transformer:
A transformer with a turns
ratio that provides a higher
than nameplate output
(secondary) voltage at no
load, and nameplate output
(secondary) voltage at rated
load. It is common for small
transformers (2 kVA and less)
to be compensated.
Conductor losses: Losses
(expressed in watts) in
a transformer that are
incidental to carrying a load:
coil resistance, stray loss
due to stray fluxes in the

windings, core clamps, and
the like, as well as circulating
currents (if any) in parallel
windings. Also called load
losses.
Continuous rating: The load
that a transformer can handle
indefinitely without
exceeding its specified
temperature rise.
Core losses: Losses
(expressed in watts) caused
by magnetization of the
core and its resistance to
magnetic flux. Also called
no-load losses or excitation
losses. Core losses are
always present when the
transformer is energized.
CSA: Canadian Standards
Association. The Canadian
equivalent of Underwriters
Laboratories (UL).
CSL3: Candidate Standard
Level 3 (CSL3) design
criteria developed by the
U.S. Department of Energy.
This term is used when
considering the maximum,
practical efficiency of a
transformer.
cUL: Mark to indicate
UL Certification to specific
CSA Standards.
Decibel (dB): Unit of
measure used to express
the magnitude of a change
in signal or sound level.
Delta connection: A
standard three-phase
connection with the ends
of each phase winding
connected in series to form a
closed loop with each phase
120 degrees from the other.
Sometimes referred to as
three-wire.
Dielectric tests: Tests that
consist of the application
of a voltage higher than the
rated voltage for a specified
time for the purpose of
determining the adequacy
against breakdowns of
insulating materials and
spacings under normal
conditions.

medium. A transformer that
is cooled by a medium other
than a liquid, normally by the
circulation of air.
E3: Eaton’s version of a CSL3
transformer.
Eddy currents: The currents
that are induced in the body
of a conducting mass by the
time variation of magnetic
flux or varying magnetic field.
Efficiency: The ratio of the
power output from a
transformer to the total
power input. Typically
expressed as a %.
Electrostatic shield: Copper
or other conducting sheet
placed between primary and
secondary windings, and
grounded to reduce electrical
interference and to provide
additional protection from
line-to-line or line-to-ground
noise. Commonly referred to
as “Faraday shield.”
Encapsulated transformer:
A transformer with its coils
either dipped or cast in
an epoxy resin or other
encapsulating substance.
Enclosure: A surrounding
case or housing used to
protect the contained
equipment against external
conditions and prevent
personnel from accidentally
contacting live parts.
Environmentally preferable
product: A product that has
a lesser or reduced negative
effect on human health
and the environment when
compared to competing
products that serve the same
purpose. This comparison
may consider raw materials
acquisition, production,
manufacturing, packaging,
distribution, reuse, operation,
maintenance and disposal
of the product. This term
includes recyclable products,
recycled products and
reusable products.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Dry-type transformer: A
transformer in which the core
and coils are in a gaseous or
dry compound insulating

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2

2
V2-T2-211

2.6
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Transformers
Transformer Standards, Technical Data and Accessories

EPACT: The Energy Policy Act
of 1992 (EPAct) is an
important piece of legislation
for efficiency because it
established minimum
efficiency levels for dry-type
distribution transformers
manufactured or imported
after December 2006. EPAct,
which was based on NEMA
standards, defined a number
of terms, including what
constitutes an energyefficient transformer. The
DOE issued a rule that
defines these transformers
and how manufacturers must
comply. DOE EPAct rule
(PDF): Energy Efficiency
Program for Certain
Commercial and Industrial
Equipment: Test Procedures,
Labeling, and the Certification
Requirements for Electric
Motors. Final Rule. 10-CFR
Part 431.
Excitation current: No load
current. The current that
flows in any winding used
to excite the transformer
when all other windings are
open-circuited. It is usually
expressed in percent of the
rated current of a winding in
which it is measured. Also
called magnetizing current.
FCAN: “Full Capacity Above
Nominal” taps. Designates
the transformer will deliver
its rated kVA when
connected to a voltage
source which is higher than
the rated primary voltage.
FCBN: “Full Capacity Below
Nominal” taps. Designates
the transformer will deliver
its rated kVA when
connected to a voltage
source which is lower than
the rated primary voltage.
Frequency: On AC circuits,
designates the number of
times that polarity alternates
from positive to negative and
back again per second, such
as 60 cycles per second.
Typically measured in
Hertz (Hz).
Ground: Connecting one
side of a circuit to the earth
through low resistance or
low impedance paths to help
prevent transmitting electrical
shock to personnel.

V2-T2-212

Harmonic: A sinusoidal
waveform with a frequency
that is an integral multiple of
the fundamental frequency
(60 Hz).
60 H3 fundamental
120 H3 2nd harmonic
180 H3 3rd harmonic
240 H3 4th harmonic
Harmonic distortion:
Nonlinear distortion of a
system characterized by
the appearance of harmonic
(non-sinusoidal) currents in
the output, when the input
is sinusoidal.
Harmonic distortion, total
(THD): The square root of
the sum of the squares of
all harmonic currents present
in a load, excluding the
fundamental 60 Hz current.
Usually expressed as a
percent of the fundamental.
High voltage windings:
In a two-winding transformer,
the winding intended to
have the greater voltage.
Usually marked with
“H” designations.
HMT: Harmonic Mitigating
Transformer (HMT) is better
able to handle the harmonic
currents present in today’s
electrical power system.
thereby increasing system
capacity, reducing distortion
throughout a facility, help
to minimize downtime and
“mysterious” maintenance
on equipment, and return the
longevity of equipment life
through reduced operational
energy losses, thereby
running cooler.
Hp: Horsepower. The energy
required to raise 33,000
pounds a distance of one foot
in one minute. 1 hp is equal
to 746 watts, or 0.746 kW.
Hi pot: A standard test
on dry-type transformers
consisting of extra-high
potentials (voltages)
connected to the windings.
Used to check the integrity
of insulation materials
and clearances.
Hottest-spot temperature:
The highest temperature
inside the transformer
winding. Is greater than
the measured average

temperature of the coil
conductors, when using the
resistance change method.
Hysteresis: The tendency of
a magnetic substance to
persist in any state of
magnetization.
Impedance: The retarding
forces of current in an AC
circuit; the current-limiting
characteristics of a
transformer. Symbol = Z
Inductance: In electrical
circuits, the opposition
to a change in the flow of
electrical current. Symbol = L
Inducted potential test:
A standard dielectric test
of transformer insulation.
Verifies the integrity of
insulating materials and
electrical clearances.
Inrush current: The initial
high peak of current that
occurs in the first few
cycles of energization, which
can be 30 to 40 times the
rated current.
Insulating transformer:
Another term for an isolating
transformer.
Insulation: Material with a
high electrical resistance.
Insulation materials: Those
materials used to insulate
the transformer’s electrical
windings from each other
and ground.
Integral TVSS or SPD: Major
Standard Change for Surge
Protective Devices (formerly
known as Transient Voltage
Surge Suppressors). The
primary safety standard for
transient voltage surge
suppressors (TVSS) has
undergone major revisions
in the past three years with
mandatory compliance by
manufacturers required by
September 29, 2009. Even
the name of the standard has
changed from UL Standard
for Safety for Transient
Voltage Surge Suppressors,
UL 1449 to UL Standard for
Safety for Surge Protective
Devices, UL 1449. This
means that TVSS listed to
the UL 1449 2nd Edition
standard will no longer be
able to be manufactured after

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

September 29, 2009. All
Surge Protective Devices
must be designed, tested,
manufactured and listed to
the UL 1449 3rd Edition
standard after this date.
Isolating transformer:
A transformer where the
input (primary) windings
are not connected to the
output (secondary) windings
(i.e., electrically isolated).
K-factor: A common industry
term for the amount of
harmonics produced by a
given load. The larger the
K-factor, the more harmonics
that are present. Also used to
define a transformer’s ability
to withstand the additional
heating generated by
harmonic currents.
kVA: Kilovolt-ampere.
Designates the output that
a transformer can deliver for
a specified time at a rated
secondary voltage and rated
frequency without exceeding
the specified temperature
rise. When multiplied by
the power factor, will give
kilowatts or kW.
1000 VA = 1 kVA
Lamination: Thin sheets
of electrical steel used to
construct the core of a
transformer.
Limiting temperature:
The maximum temperature
at which a component or
material may be operated
continuously with no sacrifice
in normal life expectancy.
Linear load: A load where
the current waveform
conforms to that of the
applied voltage, or a load
where a change in current
is directly proportional to a
change in applied voltage.
Live part: Any component
consisting of an electrically
conductive material that
can be energized under
conditions of normal use.
Load losses: I2R losses
in windings. Also see
conductor losses.

Transformers
Transformer Standards, Technical Data and Accessories

Low voltage winding: In a
two-winding transformer, the
winding intended to have
the lesser voltage. Usually
marked with “X”
designations.
Mid-tap: See center tap.
Noise level: The relative
intensity of sound, measured
in decibels (dB). NEMA
Standard ST-20 outlines
the maximum allowable
noise level for dry-type
transformers.
Nonlinear load: A load
where the current waveform
does not conform to that of
the applied voltage, or where
a change in current is not
proportional to a change in
applied voltage.
Non-ventilated transformer:
A transformer where the core
and coil assembly is mounted
inside an enclosure with no
openings for ventilation. Also
referred to as totally enclosed
non-ventilated (TENV).
No load losses: Losses in a
transformer that is excited at
rated voltage and frequency
but that is not supplying a
load. No load losses include
core losses, dielectric losses
and conductor losses in the
winding due to the exciting
current. Also referred to as
excitation losses.
Overload capability: Shortterm overload capacity is
designed into transformers as
required by ANSI. Continuous
overload capacity is not
deliberately designed into
a transformer because the
design objective is to be
within the allowed winding
temperature rise with
nameplate loading.
Percent IR (% resistance):
Voltage drop due to
resistance at rated current
in percent of rated voltage.
Percent IX (% reactance):
Voltage drop due to reactance
at rated current in percent of
rated voltage.
Percent IZ (% impedance):
Voltage drop due to
impedance at rated current
in percent of rated voltage.

Phase: Type of AC electrical
circuit; usually single-phase
two- or three-wire, or threephase three- or four-wire.
Polarity test: A standard test
on transformers to determine
instantaneous direction of
the voltages in the primary
compared to the secondary.

Sound levels: All
transformers make some
sound mainly due to the
vibration generated in its
core by alternating flux. All
Eaton general-purpose drytype distribution transformers
are designed with sound
levels lower than NEMA
ST-20 maximum levels.

Primary taps: Taps added to
the primary (input) winding.
See Tap.

Star connection: Same as a
wye connection.

Primary voltage: The input
circuit voltage.

Step-down transformer:
A transformer where the
input voltage is greater than
the output voltage.

Power factor: The cosine of
the phase angle between a
voltage and a current.
Ratio test: A standard test of
transformers to determine
the ratio of the input (primary)
voltage to the output
(secondary) voltage.
Reactance: The effect of
inductive and capacitive
components of a circuit
producing other than unity
power factor.
Reactor: A single winding
device with an air or iron
core that produces a
specific amount of inductive
reactance into a circuit.
Normally used to reduce
of control current.
Regulation: Usually
expressed as the percent
change in output voltage
when the load goes from
full load to no load.
Scott T connection:
Connection for three-phase
transformers. Instead of
using three sets of coils
for a three-phase load, the
transformer uses only two
sets of coils.
Series/multiple winding:
A winding consisting of two
or more sections that can
be connected for series
operation or multiple (parallel)
operation. Also called seriesparallel winding.
Short circuit: A low
resistance connection,
usually accidental, across
part of a circuit, resulting in
excessive current flow.

Step-up transformer:
A transformer where the
input voltage is less than
the output voltage.
T-T connection: See Scott T
connection.
Tap: A connection brought out
of a winding at some point
between its extremities,
usually to permit changing
the voltage or current ratio.
Taps are typically used to
compensate for above or
below rated input voltage,
in order to provide the rated
output voltage. See FCAN
and FCBN.
Temperature class: The
maximum temperature that
the insulation system of a
transformer can continuously
withstand. The common
insulation classes are 105,
150, 180 (also 185) and 220.
Temperature rise: The
increase over ambient
temperature of the windings
due to energizing and loading
the transformer.
Total losses: The sum
of the no-load losses and
load losses.
Totally enclosed nonventilated enclosure: The
core and coil assembly is
installed inside an enclosure
that has no ventilation to
cool the transformer. The
transformer relies on heat
to radiate from the enclosure
for cooling.

2.6

Transformer tests:
Per NEMA ST-20, routine
transformer production
tests are performed on
each transformer prior to
shipment. These tests are:
Ratio tests on the rated
voltage connection; Polarity
and Phase Relation tests on
the rated connection; NoLoad and Excitation Current
tests at rated voltage on the
rated voltage connection and
Applied Potential and Induced
Potential tests. Special tests
include sound level testing.
Transverse mode: Electrical
noise or voltage disturbance
that occurs between phase
and neutral, or from spurious
signals across metallic hot
line and the neutral
conductor.
Turns ratio: The ratio of the
number of turns in the high
voltage winding to that in the
low voltage winding.
Typical test data: Tests that
were performed on similar
units that were previously
manufactured and tested.
UL (Underwriters
Laboratories): An
independent safety
testing organization.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Universal taps: A
combination of six primary
voltage taps consisting of
2 at +2-1/2% FCAN and
4 at -2-1/2% FCBN.
Watt: A unit of electrical
power when the current in a
circuit is one ampere and the
voltage is one volt.
Wye connection: A standard
three-wire transformer
connection with similar
ends of single-phase coils
connected together. The
common point forms the
electrical neutral point and
may be grounded. Also
referred to as three-phase
four-wire. To obtain the lineto-neutral voltage, divide the
line voltage by 3 ( 1.732 ) .

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-213

2.6

Transformers
Transformer Standards, Technical Data and Accessories

2

Frequently Asked Questions About Transformers

2

Can 60 Hz transformers be used
at other frequencies?
Transformers rated for 60 Hz
can be applied to circuits with
a higher frequency, as long as
the nameplate voltages are
not exceeded. The higher the
frequency that you apply to
a 60 Hz transformer, the
less voltage regulation you
will have. 60 Hz transformers
may be used at lower
frequencies but only at
reduced voltages
corresponding to the
reduction in frequency. For
example, a 480 to 120 volt
60 Hz transformer can carry
rated kVA at 50 Hz but
ONLY when applied as a
400 to 100 volt transformer
(50/60 x 480 = 400).

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Can single-phase transformers
be used on a three-phase
source?
Yes. Any single-phase
transformer can be used
on a three-phase source by
connecting the primary
terminals of the single-phase
transformer to any two wires
of a three-phase system. It
does not matter whether the
three-phase source is threephase three-wire or threephase four-wire. The output
of the transformer will be
single-phase.
Can transformers be used to
create three-phase power from
a single-phase system?
No. Single-phase
transformers alone cannot
be used to create the phaseshifts required for a threephase system. Phase
shifting devices (reactors
or capacitors) or phase
converters in conjunction
with transformers are
required to change singlephase power to three-phase.
What considerations need to
be taken into account when
operating transformers at
high altitudes?
At altitudes greater than
3300 feet (1000 meters),
the density of the air is less
than at lower elevations. This
reduces the ability of the air
surrounding a transformer to
cool it, so the temperature
V2-T2-214

rise of the transformer is
increased. Therefore, when a
transformer is being installed
at altitudes greater than
3300 feet above sea level,
it is necessary to derate the
usable capacity of the
transformer. The table below
lists the derating factors.
As an example, a 75 kVA
480V–208Y/120V transformer
installed at 10,000 feet needs
to be derated by 4%. Instead
of 208A output, the usable
current is only 199A.

Altitude

Feet

Meters

Current
Rating
Factor

3300

1000

1.00

4000

1200

0.995

5000

1500

0.99

6000

1800

0.985

7000

2100

0.98

8000

2400

0.97

9000

2700

0.965

10,000

3000

0.96

12,000

3600

0.95

14,000

4200

0.935

15,000

4500

0.93

What considerations need to
be taken into account when
operating transformers where
the ambient temperature
is high?
Eaton’s dry-type transformers
are designed in accordance
with ANSI standards to
operate in areas where the
average maximum ambient
temperature is 40°C. For
operation in ambient
temperatures above 40°C,
there are two options:
1. Order a custom designed
transformer made for the
specific application.
2. Derate the nameplate
kVA of a standard
transformer by 8% for
each 10°C of ambient
above 40°C.

What is the normal life
expectancy of a transformer?
When a transformer is
operated under ANSI/IEEE
basic loading conditions
ANSI C57.96), its normal life
expectancy is 20 years. The
ANSI/IEEE basic loading
conditions are:
A. The transformer is
continuously loaded
at rated kVA and
rated voltages.
B. The average temperature
of the ambient air during
any 24-hour period is
equal to 30°C and at
no time exceeds 40°C.
C. The altitude where the
transformer is installed
does not exceed
3300 feet (1000 meters).
What are insulation classes?
Insulation classes were
originally used to distinguish
insulating materials operating
at different temperatures. In
the past, letters were used
for the different designations.
Recently, insulation system
temperatures (°C) have
replaced the letters’
designations.
Insulation Classes
Previous
Designation

Insulation
System
Rating (°C)

Class A

105

Class B

150

Class F

180

Class H

220

Class R

220

How do you know if the
enclosure temperature is
too hot?
UL and CSA standards
strictly regulate the
highest temperature that
an enclosure can reach. For
ventilated transformers, the
temperature of the enclosure
should not increase by more
than 50°C in a 40°C ambient
at full rated current. For
encapsulated transformers,
the temperature of the
enclosure should not increase
by more than 65°C in a

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

25°C ambient at full rated
current. This means that
it is permissible for the
temperature of the enclosure
to reach 90°C (194°F).
Although this temperature is
very warm to the touch, it is
within the allowed standards.
A thermometer should be
used to measure enclosure
temperatures, not your hand.
Can transformers be reverseconnected (reverse-fed)?
Yes, with limitations. Eaton
single-phase transformers
rated 3 kVA and larger can be
reverse-connected without
any loss of kVA capacity
or any adverse effects.
Transformers rated 2 kVA
and below, because there is a
turns ratio compensation on
the low voltage winding that
adjusts voltage between no
load and full load conditions,
should not be reverse-fed.
Three-phase transformers
with either delta-delta or
delta-wye configurations
can also be reverseconnected for step-up
operation. When reversefeeding a delta-wye
connected transformer,
there are two important
considerations to take into
account: (1) The neutral is
not connected, only the
three-phase wires of the wye
system are connected, and
(2) the ground strap between
X0 and the enclosure must
be removed. Due to high
inrush currents that may be
created in these applications,
it is recommended that
you do not reverse-feed
transformers rated more
than 75 kVA. The preferred
solution is to purchase an
Eaton step-up transformer
designed specifically for
your application.

Transformers
Transformer Standards, Technical Data and Accessories

Can transformers be connected
in parallel?
Yes, with certain restrictions.
For single-phase transformers
being connected in parallel,
the voltages and impedances
of the transformers must be
equal (impedances must be
within 7.5% of each other).
For three-phase transformers,
the same restrictions apply as
for single-phase transformers,
plus the phase shift of the
transformers must be the
same. For example, a deltawye–connected transformer
(30° phase shift) must be
connected in parallel with
another delta-wye–connected
transformer, not a delta-delta
connected–transformer
(0° phase shift).

Why is the impedance of a
transformer important?
The impedance of a
transformer is important
because it is used to
determine the interrupting
rating and trip rating of the
circuit protection devices on
the load or line side of the
transformer. To calculate
the maximum short circuit
current on the load side of
a transformer, use the
following formula:
Maximum Short Circuit =
Load Current (Amps)
Full Load Current (Amps)
Transformer Impedance

Full load current for singlephase circuits is:
Nameplate Volt-Amps
-----------------------------------------------------Load (output) Voltage

and for three-phase circuits,
the full load current is:
Nameplate Volts-Amps
-----------------------------------------------------Load (output) Volts

3

Example: For a standard
three-phase, 75 kVA
transformer, rated 480 volt
delta primary and 208Y/
120 volt secondary (catalog
number V48M28T75J) and
impedance equal to 5.1%,
the full load current is:

2.6

What clearances are required
around transformers when they
are installed?
All dry-type transformers
depend upon the circulation of
air for cooling; therefore, it is
important that the flow of air
around a transformer not be
impeded. UL 1561 requires
that there be no less than
6 inches (152.4 mm) clearance
between any side transformer
with ventilation openings and
any wall or obstruction.
In compliance with
NEC 450.9, Eaton’s ventilated
transformers have a note on
their nameplates requiring
a minimum of 6 inches
(152.4 mm) clearance from
the ventilation openings and
walls or other obstructions.
This clearance only addresses
the ventilation needs of the
transformer. There may
be additional local codes
and standards that affect
installation clearances.

2
2
2
2
2
2
2
2
2
2
2
2
2

Transformers should not be
mounted in such a manner
that one unit will contribute
to the additional heating
of another unit, beyond
allowable temperature limits,
for example, where two units
are mounted on a wall one
above the other.

2
2
2
2
2

75,000 VA
----------------------------- = 208.2A
208V

1.732

2

The maximum short circuit
load current is:

2

208.2A
------------------ = 4,082.4A
0.051

2

The circuit breaker or fuse
on the secondary side of this
transformer would have to
have a minimum interrupting
capacity of 4083 amperes at
208 volts. NEMA ST-20 (1992).

2
2
2

A similar transformer with
lower impedance would
require a primary circuit
breaker or fuse with a higher
interrupting capacity.

2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-215

2.7
2
2
2

Transformers
Dimensions

Dimensions
Approximate Dimensions in Inches (mm)
Enclosure Dimensional Drawings—Ventilated Transformers
Outside
Width

2
2

Outside
Width
Top

2
2
2

Top
Outside
Width
Outside
Height

Front
Left

Top
Front

2
2

Outside
Height

Outside
Height

Outside
Length

2

Left
Left

Front

Drawing 1

2
2
2

Outside
Length

2

Outside
Length
Drawing 2

2

Drawing 3

2
2

Drawing
Number

Dimensions

Frame

Height

Width

Length

FR816

1

31.30 (795.0)

22.89 (581.4)

18.39 (467.2)

2

FR818

1

37.59 (954.8)

22.89 (581.4)

20.36 (517.1)

FR819

2

42.03 (1067.6)

24.22 (615.2)

23.84 (605.5)

2

FR820

2

42.03 (1067.6)

24.22 (615.2)

23.84 (605.5)

FR814

2

62.91 (1597.9)

29.97 (761.2)

33.97 (862.8)

2

FR842

1

33.75 (857.3)

22.45 (570.2)

17.40 (442.0)

FR843

1

38.70 (983.0)

23.51 (597.2)

24.38 (619.3)

2

FR844

2

44.92 (1141.0)

26.27 (667.3)

27.12 (688.8)

FR821

2

62.91 (1597.9)

29.97 (761.2)

33.97 (862.8)

2

FR912D, FR912D 1

30.00 (762.0)

23.00 (584.2)

16.50 (419.1)

FR914D/FR914F

1

39.00 (990.6)

29.00 (736.6)

22.00 (558.8)

2

FR915D/FR915F

1

39.00 (990.6)

29.00 (736.6)

22.00 (558.8)

FR916A

2

48.56 (1233.4)

28.22 (716.8)

23.42 (594.9)

2

FR917

2

56.17 (1426.7)

31.44 (798.6)

24.67 (626.6)

2

FR918A

2

62.18 (1579.4)

31.44 (798.6)

30.68 (779.3)

FR923

2

57.54 (1461.5)

36.69 (931.9)

32.65 (829.3)

FR924

2

68.37 (1736.6)

44.46 (1129.3)

36.44 (925.6)

FR928

2

56.16 (1426.5)

32.93 (836.4)

27.97 (710.4)

FR929

2

59.56 (1512.8)

36.72 (932.7)

32.50 (825.5)

FR919

3

75.00 (1905.0)

44.20 (1122.7)

36.23 (920.2)

FR920

3

75.00 (1905.0)

44.20 (1122.7)

36.23 (920.2)

FR922

3

90.00 (2286.0)

69.26 (1759.2)

42.65 (1083.3)

2

2
2
2

V2-T2-216

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.7

Transformers
Dimensions

Approximate Dimensions in Inches (mm)

2
2

Enclosure Dimensional Drawings—Encapsulated Transformers (Type EP)
Outside
Width

Outside
Width

Top

Top

Outside
Length

Right

Outside
ck Height

Outside
Length

Ba

2
Top

Outside
Width

Outside
Height
Right Back

Outside
Length

2

Outside
Height
Right

2

Back

2
2

Drawing 6

Drawing 8

Drawing 7

2
2

Outside
Width

2

Top

Outside
Width

2

Outside
Width
Top

Outside
Height

Outside
Length
Right

Outside
Length

2

Back

Outside
Height
Right

2

Top

Outside
Height

Outside
Length

Back

Right

Back

2
2

Drawing 10

Drawing 9

2

2

Drawing 11

2
Drawing
Number

Dimensions

Frame

Height

Width

Length

FR52

6

8.91 (226.3)

4.11 (104.4)

4.00 (101.6)

FR54

6

8.91 (226.3)

4.11 (104.4)

4.00 (101.6)

FR55

6

8.91 (226.3)

4.11 (104.4)

4.00 (101.6)

FR56

7

8.97 (227.8)

4.87 (123.7)

4.06 (103.1)

FR57

7

8.97 (227.8)

4.87 (123.7)

4.91 (124.7)

FR58A

7

11.28 (286.5)

5.99 (152.1)

5.75 (146.1)

FR59A

7

11.28 (286.5)

5.99 (152.1)

5.75 (146.1)

FR67

7

13.41 (340.6)

6.37 (161.8)

6.52 (165.6)

FR68

7

13.41 (340.6)

6.37 (161.8)

6.52 (165.6)

FR176

8

14.25 (361.9)

7.69 (195.3)

8.00 (203.2)

FR177

9

16.00 (406.4)

10.38 (263.7)

9.89 (251.2)

FR301

11

22.26 (565.4)

12.71 (322.8)

12.79 (324.9)

FR178

9

16.00 (406.4)

10.38 (263.7)

9.89 (251.2)

FR302

11

25.26 (641.6)

12.71 (322.8)

12.79 (324.9)

FR304

11

25.26 (641.6)

14.72 (373.9)

14.82 (376.4)

FR179

9

19.00 (482.6)

13.38 (339.9)

10.52 (267.2)

FR180

9

19.00 (482.6)

13.38 (339.9)

10.52 (267.2)

FR182

10

23.31 (592.1)

16.35 (415.3)

14.12 (358.6)

FR190

10

26.31 (668.3)

16.35 (415.3)

14.12 (358.6)

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2
2
2
2
2
2
2
2
2
2
2
2
V2-T2-217

2.7

Transformers
Dimensions

2

Approximate Dimensions in Inches (mm)

2

Enclosure Dimensional Drawings—Encapsulated Transformers Type EP (Single-Phase), continued

2

Outside
Width

2

Top

2
Outside
Width

2
2

Outside
Length

Outside
Height
Left

Top

Front
Outside
Width

2
2

Top

Outside
Height

Outside
Length

2

Drawing 13

Front

2

Left

Outside
Length

Outside
Height
Right

Back

2
2
2

Drawing 14

Drawing 12

2
2

Drawing
Number

Dimensions

Frame

Height

Width

FR132

13

20.67 (525.0)

19.02 (483.1)

13.59 (345.2)

2

FR300A

12

28.24 (717.3)

22.42 (569.5)

14.06 (357.1)

FR57P

14

9.34 (237.2)

4.45 (113.0)

5.18 (131.6)

2

FR58AP

14

11.68 (296.7)

4.99 (126.7)

5.99 (152.1)

FR567P

14

13.03 (330.9)

5.74 (145.8)

6.56 (166.6)

FR568P

14

13.78 (350.0)

6.22 (158.0)

6.32 (160.5)

2

2

Length

2
2
2
2
2
2
2
2
2
2
V2-T2-218

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.7

Transformers
Dimensions

Approximate Dimensions in Inches (mm)

2

Enclosure Dimensional Drawings—Encapsulated Transformers (Type EPT)

2

Outside
Length

Outside
Width

2
2

Outside
Width

Top

Top
Outside
Height

Front
Outside
Height

Outside
Height

Front

Left

2

Top

Left

Left

2
2

Front

2
Outside
Length

Drawing 15

Drawing 16

2

Outside
Width

Outside
Length

2
2

Drawing 17

2

Dimensions

Frame

Drawing
Number

Height

Width

Length

FR201

15

13.40 (340.4)

15.93 (404.6

8.26 (209.8)

FR102

15

13.12 (333.2)

19.59 (497.6)

7.09 (180.1)

FR103

15

15.90 (403.9)

16.93 (430.0)

10.01 (254.3)

FR200

15

15.90 (403.9)

16.93 (430.0)

10.01 (254.3)

FR97

15

15.19 (385.8)

25.68 (652.3)

8.38 (212.9)

FR95

15

17.38 (441.5)

20.00 (508.0)

10.52 (267.2)

FR243

16

17.38 (441.5)

20.00 (508.0)

10.52 (267.2)

FR96

15

16.19 (411.2)

29.68 (753.9)

9.42 (239.3)

FR244

16

28.15 (715.0)

26.58 (675.1)

14.66 (372.4)

FR245

17

32.06 (814.3)

30.29 (769.4)

15.68 (398.3)

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-219

2.7

Transformers
Dimensions

2

Approximate Dimensions in Inches (mm)

2

Enclosure Dimensional Drawings—Core-Coil Transformers

2

Top

2
2
2
2
2

Top

Outside
Height

2

Outside
Height

2
2
2
2

Front

Front
Left

2

Outside
Width

Outside
Length

2
2

Drawing 5

Drawing
Number

Dimensions

Frame

Height

Width

Length

2

FR817C

4

39.28 (997.7)

21.62 (549.1)

19.51 (495.6)

FR818C

4

39.28 (997.7)

21.62 (549.1)

19.51 (495.6)

2

FR912C

5

24.75 (628.7)

19.50 (495.3)

14.00 (355.6)

FR914C

5

29.37 (746.0)

25.12 (638.0)

19.00 (482.6)

2

FR915C

5

31.38 (1067.6)

25.12 (638.0)

19.00 (482.6)

2

FR9516C

5

41.43 (1052.3)

25.12 (638.0)

20.00 (508.0)

FR916AC

5

43.40 (1102.4)

27.22 (691.4)

22.82 (579.6)

2

Outside
Length

Drawing 4

2

2
2
2
2
2
2
2
2
V2-T2-220

Outside
Width

Left

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

2.7

Transformers
Dimensions

Approximate Dimensions in Inches (mm)

2

Enclosure Dimensional Drawings—Totally Enclosed Nonventilated Transformers

2
2
Outside
Width

2
2
Top

Outside
Width
Top

2
2

Outside
Width

2

Front

Outside
Height

2

Top

Front
Left

Outside
Height
Outside
Height

Outside
Length

2

Left

Left

2
2

Front

Drawing 26

2
2
2

Outside
Length

Outside
Length
Drawing 27

2
2

Drawing 28

2

Drawing
Number

Dimensions

Frame

Height

Width

Length

FR818N

26

37.59 (954.8)

22.89 (581.4)

20.36 (517.1)

FR819N

27

42.03 (1067.6)

24.22 (615.2)

23.84 (605.5)

FR820N

27

42.03 (1067.6)

24.22 (615.2)

23.84 (605.5)

FR814N

27

62.91 (1597.9)

29.97 (761.2)

33.97 (862.8)

FR912DN

26

30.00 (762.0)

23.00 (584.2)

16.50 (419.1)

FR914DN/FR914FN

26

39.18 (995.2)

29.00 (736.6)

22.00 (558.8)

FR915DN/FR915FN

26

39.18 (995.2)

29.00 (736.6)

22.00 (558.8)

FR916AN

27

46.58 (1183.1)

28.22 (716.8)

23.42 (594.9)

FR917N

27

56.18 (1427.0)

31.44 (798.6)

24.67 (626.8)

FR918AN

27

62.18 (1579.4)

31.44 (798.6)

30.68 (779.3)

FR923N

27

57.50 (1460.5)

36.69 (931.9)

32.65 (829.3)

FR919N

28

75.00 (1905.0)

44.21 (1122.9)

36.23 (920.2)

FR920N

28

75.00 (1905.0)

44.21 (1122.9)

36.23 (920.2)

2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-221

2.7

Transformers
Dimensions

2

Approximate Dimensions in Inches (mm)

2

Enclosure Dimensional Drawings—Hazardous Location Transformers (Type EPZ)

2
Outside
Length

2

Right
Back

Back

2

Top

Outside
Height

Outside
Height
Right

Outside
Height
Right

Outside
Width

2
2

Back

Outside
Width

Drawing 21

Drawing 22

2

Outside
Width

2
2

Drawing 23

Outside
Length

2

Outside
Length
Top

2

Top

2

Outside
Height

2

Right

Outside
Height

Back

2

Right

Back

2
2

Outside
Width

Outside
Width

2
Drawing 24

2
2

Drawing 25

2

Drawing
Number

Dimensions

Frame

Height

Width

Length

2

FR57H

21

8.97 (227.8)

4.87 (123.7)

4.91 (124.7)

FR58H

22

11.28 (286.5)

5.99 (152.1)

5.75 (146.1)

2

FR59H

22

11.28 (286.5)

5.99 (152.1)

5.75 (146.1)

FR67H

22

13.41 (340.6)

6.37 (161.8)

6.52 (165.6)

2

FR68H

22

13.41 (340.6)

6.37 (161.8)

6.52 (165.6)

FR176H

23

14.25 (361.9)

7.69 (195.3)

8.00 (203.2)

2

FR177H

24

16.00 (406.4)

10.38 (263.7)

9.89 (251.2)

2

FR178H

24

16.00 (406.4)

10.38 (263.7)

9.89 (251.2)

FR179H

24

19.00 (482.6)

13.38 (339.9)

10.52 (267.2)

FR180H

24

19.00 (482.6)

13.38 (339.9)

10.52 (267.2)

FR182H

25

23.31 (592.1)

16.35 (415.3)

14.12 (358.6)

2

Outside
Length

Top

Top

2
2

Outside
Width

Outside
Length

2
V2-T2-222

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

Transformers
Dimensions

2.7

Approximate Dimensions in Inches (mm)

2

Enclosure Dimensional Drawings—Hazardous Location Transformers (Type EPTZ)

2
2

Outside
Length
Outside
Width
Top

Outside
Width

Left

2

Outside
Height

Front

Front

2

Top

Outside
Height
Outside
Height

2

Top

2

Front

Left

2

Left
Outside
Width

Outside
Length

2

Outside
Length
Drawing 18

Drawing 19

2
Drawing 20

2
2

Dimensions

Frame

Drawing
Number

Height

Width

Length

FR201H

18

13.40 (340.4)

15.93 (404.6)

8.26 (209.8)

FR200H

18

15.90 (403.9)

16.93 (430.0)

10.01 (254.3)

FR103H

18

15.90 (403.9)

16.93 (430.0)

10.01 (254.3)

FR95H

18

17.38 (441.5)

20.00 (508.0)

10.52 (267.2)

FR243H

19

17.38 (441.5)

20.00 (508.0)

10.52 (267.2)

FR244H

19

28.15 (715.0)

26.58 (675.1)

14.66 (372.4)

FR245H

20

32.06 (814.3)

30.29 (769.4)

15.68 (398.3)

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 2—Commercial Distribution CA08100003E—July 2016 www.eaton.com

V2-T2-223



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Zoltun Design
Create Date                     : 2016:10:22 15:07:20+05:30
Modify Date                     : 2016:10:22 15:07:20+05:30
Subject                         : Transformers
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 11.0 (Windows)
Format                          : application/pdf
Creator                         : Zoltun Design
Title                           : Volume 2 Tab 2
Description                     : Transformers
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2016:07:01 09:15:04-05:00
Document ID                     : uuid:b49bc77b-421f-4247-ab40-c8df8299ec00
Instance ID                     : uuid:45c56213-284e-4612-9e3d-aa294d77f9dc
Page Count                      : 223
EXIF Metadata provided by EXIF.tools

Navigation menu