Brochure
2016-10-06
: Pdf 145613-Brochure 145613-Brochure B5 unilog
Open the PDF directly: View PDF
.
Page Count: 424
| Download | |
| Open PDF In Browser | View PDF |
Catalog | March 2015 Catalog 2015 Electronic Products and Relays 2 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Machine Safety Jokab Safety products Productivity and safety go hand in hand Jokab Safety was acquired by ABB in 2010. This gives us extra strength and a sales network in 120 countries. Our goal is to become even better at supporting you as a customer through cooperation within ABB Jokab Safety globally and locally. The fact that the leading power and automation technology company, ABB, and a leader in machine safety, Jokab Safety, have joined forces means a lot more than just a new organizational chart. ABB has a huge footprint in the industry - from power supply to the control of each individual motor - and has been delivering reliable solutions for decades that boost productivity in the industry. The acquisition of Jokab Safety means the last building block is in place. We can now offer our customers tailored, turnkey solutions where machine safety is an integral and value-enhancing component. Jokab Safety offering: –– Safety PLC Pluto, Pluto AS-i, Gateways, Safe Encoder –– Safety controller Vital and Tina safety systems –– Safety relays RT series, JSB series, safety timers, expansion relays –– Light curtains, light grids, light beams and scanner Focus II, Spot, Look –– Sensors, switches and locks Eden, Sense, MKey, Magne, Dalton, Knox –– Control devices JSHD4, Safeball, Fox2 –– Emergency stop devices Inca, Smile, EStrong, LineStrong –– Contact rails, bumpers and safety mats –– Fencing systems Quick-Guard, SafeCad, Roller doors Further information: „ABB Safety Handbook“ - Order code: 2TLC172001C0202 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3 Electronic Products and Relays News Thermistor motor protection relays in new housing The thermistor motor protection relays of the CM-MSS range monitor the winding temperature of motors which have PTC temperature sensors installed. These sensors are incorporated in the motor windings thus measuring the motor heat directly. This direct temperature measurement enables the thermistor motor protection relays to evaluate various motor conditions such as overheating, overload and insufficient cooling. Depending on the product also the ATEX approval is available for the use in hazardous areas. The new housing provides two different connection terminals: The proven double-chamber cage connection terminals and the Easy Connect Technology with Push-in terminals. CR-S Range pluggable small interface relays The pluggable interface relays of the CR-S Range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The CR-S Range combines the flexibility of a modular system and the ability of switching high currents on a small footprint thus can be used in applications where space saving is essential. Universal Motor Controller UMC100.3 now available The intelligent ABB Motor Controllers for motor protection, motor control, fieldbus and Ethernet communication and fault diagnosis. Due to the benefits it provides, the UMC is used worldwide in many segments and in Projects with several thousand motor controllers. Beside the proven UMC100 the new UMC100.3 offers even more capabilities like 24 V DC or 110-220 V AC/DC supply voltage and fieldbus communication interfaces. Grid feeding monitoring relays from the CM-UFD.Mx range The multifunctional grid feeding monitoring relays of the CM-UFD range are designed to monitor several grid parameters when feeding energy into the public grid. The intention is to trip a section switch which is connected between the distributed generation and the public grid in order to disconnect the distributed generation in case of problems (e.g. unstable grid), faults or maintenance on the grid. Different monitoring functions such as 10-minutes average value, real time over- and undervoltage as well as over- and underfrequency are configurable via the front face display. –– CM-UFD.M22: Third party certificate confirming accordance with CEI 0-21: 2012-06 + CEI 0-21; V1: 2012-12 + A70 Terna –– CM-UFD.M31: Third party certificate confirming accordance with VDE-AR-N 4105: 2011-08; BDEW, June 2008 “Technische Richtlinie – Erzeugungsanlagen am Mittelspannungsnetz” including supplementary provisions of January 2013 –– CM-UFD.M33: Factory certificate confirming accordance with Engineering Recommendation G59 Issue 3 - September 2013; Engineering Recommendation G83 Issue 2 - December 2012 4 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Electronic Products and Relays Table of contents Electronic timers 1/1 Measuring and monitoring relays 2/1 Primary switch mode power supplies 3/1 Analog signal converters, serial data converters 4/1 Interface relays and optocouplers 5/1 Logic relays 6/1 Index 7/1 1 2 3 4 5 6 7 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5 Approvals and marks for the world market Overview ABB low-voltage switching devices are developed and produced in accordance with the applicable regulations as stated in the international IEC publications, the European EN specifications and the national VDE standards. In most countries, low-voltage switching devices are produced according to such regulations under the responsibility of the manufacturers. This is why the devices are not subject to further approval. However, for those devices which are intended for use in household or for public use our customers can request test reports of our internal laboratory for presentation to the various qualified local organizations. In other countries, approvals are prescribed by law. For devices installed in ships, an approval issued by independent shipping companies, such as the GL, are demanded by the maritime insurance companies. Marks of conformity and examples of approvals (device-dependent) Berufsgenossenschaft der Feinmechanik und Elektrotechnik (BGFE) International CB scheme K The CB (Certification Body) Scheme is a system designed to facilitate international trade by establishing mutual acceptance of test reports among participating safety certification organizations (the National Certification Bodies) in more than 30 countries. The CB Scheme was e stablished by the International Electrotechnical Committee for Conformity Testing to Standards for Electrical Equipment (IECEE). The BG-PRÜFZERT sign is a voluntary safety mark, awarded by the BGFE following successful safety testing. Explosion protection (EX) Conformité Européen (CE) Swiss insurance institution (SUVA) Q Department accident prevention suvaPRO C Shipping approval a All devices which comply with the European low voltage directive and which are intended for sale within the European Union must have the CE sign applied. All products in this catalog are CE marked. The CE sign must not be confused with a certificate of quality issued by the EU. It is solely used to confirm that the respective product complies with the applicable European directives *). The CE sign is part of an administrative procedure to guarantee free movement of goods within the European Community. *) Directives: Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Machinery Directive 98/37/EEC Verband der Elektrotechnik Elektronik Informationstechnik (VDE) I Explosion protection acc. to Directive 94/9/EG (ATEX 100a) Germanischer Lloyd (GL) Europe M Lloyds Register P Shipping approval In Russia, low-voltage switching devices are subject to certification and have to be provided with a sign. R EAC certification is mandatory for many products. This certification is based on a safety test (IEC standards with Russiaspecific deviations) and an EMC test. Russian Maritime Register of Shipping RMRS L Shipping approval J Applicable for technical instruments covered by the German Gerätesicherheitsgesetz (GSG) as well as for single parts and electrical wiring devices. Australia, New Zealand C-Tick Mark b E In China the CCC certification mark is a compulsory certification mark in the field of safety and quality for products sold on the Chinese market. North America Canadian and US standards are more or less equivalent but considerably differ from the IEC and VDE regulations. USA Underwriters Laboratories (UL) Listing B Released for installation in systems and for sale as individual component in the USA. G Released for installation in systems, if the respective system has been completely mounted and wired by qualified personnel. Canada Canadian Standards Association (CSA) F USA and Canada The combined UL signs for the USA and Canada are recognized by the authorities of both countries. Devices with this certificate meet the requirements of both countries. Listing The C-Tick Mark certifies compliance with the Australian EMC requirements. The Mark is also recognized in New Zealand. 6 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CCC (China Compulsory Certification) Recognition Russia Eurasian Conformity China Recognition A H Find Electronic Products and Relays product information and documentation on our web page The following steps will guide you to the documentation and product search section of the Electronic Products and Relays portfolio on www.ABB.com. Enter http://new.abb.com/low-voltage/products/epr in your internet browser. You will be redirected to the following page: Latest information about the Electronic Products and Relays product range could be found in the Highlights section. In the lower area of the web page you can find the Our offering section. The assortment of the Electronic Products and Relays range is listed here as shown in the screenshot below: Select the register of the relevant product group to see all the products related to the product group. Choose a product range from which you want to see the documentation or from which you want to choose a specific product. In this example the CT-S range from the register Electronic timers has been selected as shown on the screenshot. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 7 Find Electronic Products and Relays product information and documentation on our web page You will be redirected to the following page: Latest information about the Electronic Products and Relays product range could be found in the Highlights sections. In the lower area of the web page you can find the Products and documents section. The functions to choose a product or a document are listed here as in the screenshot below: To search for a product continue on page 9. To search for documentation continue on page 10. 8 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Find Electronic Products and Relays product information and documentation on our web page How to find the right product Click on Filters to see the different search attributes for the selected product range. The filter section will be expanded as shown below. The different product filters are shown. Click on the filter attribute to continue the product search process. In this example Output has been chosen. In the right part mark the corresponding check box to narrow down the search. You can also select several check boxes. Click on Apply to submit your filter. The search results are now listed according to your selection. Proceed this approach with different filters until the right product is listed. Click on the product in the Result section to get the dedicated product information listed in your browser. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 9 Find Electronic Products and Relays product information and documentation on our web page How to find the right documentation Click on Documents to see the different types of documentation for the product. The document section will be expanded as shown below. On the left side select the type of document related to the product. In the example Popular documents has been selected. In the right area click on the document related to the product. The document is opened or downloaded, depending on the individual browser settings. 10 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 EPR Catalog 2015 Notes 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 11 Electronic timers Product group picture 1 1/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Electronic timers Table of contents Electronic timers Table of contents 1/2 Overview 1/3 Approvals and marks 1/4 CT-D range 1/5 Table of contents 1/6 Benefits and advantages 1/7 Ordering details 1/8 Function diagrams 1/9 Connection diagrams 1/12 Technical data 1/13 Technical data, Technical diagrams 1/15 Wiring notes, Dimensional drawings 1/16 CT-E range 1/17 Table of contents 1/18 Benefits and advantages 1/19 Ordering details 1/20 Function diagrams 1/22 Connection diagrams 1/27 Connection diagrams, Technical diagrams 1/28 Technical data 1/29 Wiring notes, Dimensional drawings 1/31 CT-S range 1/33 Table of contents 1/34 Benefits and advantages 1/35 Ordering details - multifunctional 1/37 Ordering details - singlefunctional 1/38 Ordering details - Accessories 1/39 Function diagrams 1/41 Connection diagrams 1/49 Technical data 1/52 Technical diagrams 1/55 Wiring notes, Dimensional drawings 1/56 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/2 1 Electronic timers Overview 1 CT-D range Timing function multifunctional CT-E range single-functional multifunctional single-functional CT-S range multifunctional single-functional A ON-delay CT-MFD CT-ERD CT-MFE, CT-MKE CT-ERE, CT-EKE CT-MVS, CT-MFS, CT-MBS, CT-WBS CT-ERS B OFF-delay CT-MFD CT-AHD CT-MFE CT-AHE, CT-ARE, CT-AKE CT-MVS, CT-MFS, CT-MBS CT-APS, CT-AHS, CT-ARS AB ON- and OFF-delay CA Impulse-ON CT-MFD CB Impulse-OFF CT-MFD CE Impulse-ON and OFF DA Flasher starting with ON CT-MFD DB Flasher staring with OFF CT-MFD DE Flasher starting with ON or OFF ED Pulse generator starting with ON or OFF H Pulse former F Star-delta change-over CT-VWD CT-MFE, CT-MKE CT-VWE CT-AWE CT-EBD CT-MFE, CT-MKE CT-MFE, CT-MKE CT-EBE CT-TGD CT-MFD CT-MVS, CT-MXS, CT-MFS, CT-MBS CT-MVS, CT-MFS, CT-MBS, CT-WBS CT-MVS, CT-MFS, CT-MBS CT-MXS CT-MFS, CT-MBS, CT-WBS CT-MFS, CT-MBS, CT-WBS CT-MVS CT-MXS CT-MFE CT-MVS, CT-MFS, CT-MBS CT-SDD, CT-SAD CT-SDS CT-SDE FC Star-delta change-over with impulse CT-MVS.2x, CT-MFS, CT-MBS CT-YDE FA Star-delta change-over twice ON-delayed A+ AC BC CT-MVS, CT-MXS, CT-MFS, CT-MBS, CT-WBS G further functions (depending on device) Technical data (extract) Time ranges 7 (0.05 s - 100 h) CT-SDD, CT-SAD: 4 (0.05 s - 10 min) Multifunction devices: 8 (0.05 s - 100 h) Single-function devices: 5 single ranges (0.05-1 s, 0.1-10 s, 0.3-30 s, 3-300 s, 0.3-300 min) 10 (0.05 s - 300 h) CT-ARS, CT-SDS: 7 (0.05 s- 10 min) Control supply voltage Wide and multi ranges Wide ranges Wide, multi and single ranges Type and number of contacts 1 or 2 c/o contacts CT-SDD, CT-SAD: 2 n/o contacts 1 c/ o contact CT-SDE: 1 n/o contact and 1 n/c contact CT-MKE, CT-EKE, CT-AKE: 1 thyristor 1 or 2 c/o contacts CT-MVS.21, CT-MFS, CT-MBS: 2nd c/o contact selectable as inst. contact CT-SDS: 2 n/o contacts Control inputs voltage-related triggering, polarized, capable of switching a parallel load voltage-related triggering, polarized CT-MFE, CT-AHE, CT-AWE: with auxiliary voltage voltage-related triggering, nonpolarized, capable of switching a parallel load CT-MFS, CT-MBS, CT-AHS: volt-free triggering 1/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Single and dual ranges Electronic timers Approvals and marks CT-D J J J J J J J J J J CT-SAD.22 J CT-SDD.22 CT-AHD.12 J J CT-TGD.22 CT-ERD .22 J CB scheme CT-EBD.12 CT-ERD.12 UL 508, CAN/CSA C22.2 No.14 K CT-VWD.12 CT-MFD.21 A Approvals 1 CT-AHD.22 CT-MFD.12 existing pending CT-TGD.12 J j J J J J EAC J J J J J J J J J J J J E CCC J J J J J J J J J J J J L RMRS J J J J J J J J J J a CE J J J J J J J J J J J J b C-Tick J j J j J j J J J j j j Marks CT-E CT-MFE CT-ERE CT-AHE CT-ARE CT-VWE CT-AWE CT-EBE CT-YDE CT-SDE CT-MKE CT-EKE CT-AKE J existing j pending A UL 508, CAN/CSA C22.2 No.14 J J J J J J J J J J J J C GL J J J J J J J J J J J J K CB scheme J J J J J J J J J J J J Approvals EAC J J J J J J J J J E CCC J J J J J J J J J L RMRS J J J J J J J J J J J J a CE J J J J J J J J J J J J b C-Tick J J J J J J J J J J J J Marks CT-S CT-MVS.12S/P CT-MVS.2xS/P CT-MXS.22S/P CT-MFS.21S/P CT-MBS.22S/P CT-WBS.22S/P CT-ERS.12S/P CT-ERS.2xS/P CT-APS.12S/P CT-APS.2xS/P CT-AHS.22S/P CT-ARS.11S/P CT-ARS.21S/P CT-SDS.2xS/P J existing j pending A UL 508, CAN/CSA C22.2 No.14 J J J J J J J J J J J J J J C GL J J J J J J J J J J J j j J EAC J J J J J J J J J J J J J J K CB scheme J J J J J J J J J J J J J J E CCC J J J J J J J J J J J J J J L RMRS J J J J J J J J J J J J J J J J J Approvals Rail applications 1) J J J Marks a CE J J J J J J J J J J J J J J b C-Tick J J J J J J J J J J J J J J 1) Applicable in rail application following the latest standards for rail applications. Further information are available in our rail segment brochure 2CDC110084B0201. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/4 CT-D range Product group picture 1 1/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CT-D range Table of contents CT-D Range Benefits and advantages 1/7 Ordering details 1/8 Function diagrams 1/9 Connection diagrams 1/12 Technical data 1/13 Technical data, Technical diagrams 1/15 Wiring notes, Dimensional drawings 1/16 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/6 1 CT-D range Benefits and advantages Characteristics –– Diversity: –– 2 multifunction timers –– 10 single-function timers –– Control supply voltages: –– Wide range: 12-240 V AC/DC –– Multi range: 24-48 V DC, 24-240 V AC –– 7 time ranges from 0.05 s to 100 h or 4 time ranges from 0.05 s to 10 min –– Width of only 17.5 mm –– Light-grey housing in RAL 7035 –– Devices with: 1 c/o contact (250 V / 6 A) or 2 c/o contacts (250 V / 5 A) Control input: voltage-related triggering, polarized, capable of switching parallel loads –– Approvals / Marks (partly pending, details see page 1/4) –– A, K1), E, 1) Benefits Direct reading scales 1 Direct setting of the time delay without any additional calculation provides accurate time delay adjustment. LEDs for status indication 2 All actual operational states are displayed by front-face LEDs, thus simplifying commissioning and troubleshooting. Switching currents The CT-D range timers allow an output load of up to 6 A on devices with 1 c/o contact and up to 5 A on devices with 2 c/o contacts. Connection terminals 3 Wide terminal spacing allows connection of wires: 2 x 1.5 mm² (2 x 16 AWG) with wire end ferrules or 2 x 2.5 mm² (2 x 14 AWG) without ferrules. , L / a, b Only for devices with 1 c/o (SPDT) contact 4 Width 17.5 mm With their width of 17.5 mm only, the CT-D range timers are ideally suited for installation in distribution panels. Operating controls 1 LEDs for status indication U - green LED: V control supply voltage applied W timing R, R1, R2 - yellow LED: V output relay energized 3 2 2 Time range adjustment 3 Fine adjustment of the time delay 1 4 Preselection of the timing function 3 4 2 3 2CDC 253 021 F0004 2 2CDC 253 033 F0004 1 2CDC 253 132 F0006 single-functional multifunctional 2CDC 253 066 F0006 1 4 17.5 mm 1/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CT-D range Ordering details Description The CT-D range in MDRC design with a width of only 17.5 mm fits into all domestic installation and distribution panels. The CT-D range represents a link between industry and the installation types. For maximum flexibility in operation, 10 single-function as well as 2 multifunction devices with 7 timing functions are available. The devices offer 4 or 7 time ranges from 0.05 seconds up to 100 hours. Their wide input range allows the use in applications worldwide. Ordering details 2CDC 251 089 F0006 Timing function Rated control supply voltage Time ranges Control input Multifunctional1) 24-240 V AC 24-48 V DC 7 (0.05 s 100 h) M 1 c/o CT-MFD.12 1SVR500020R0000 0.060 (0.132) Multifunctional1) 12-240 V AC/DC 7 (0.05 s 100 h) M 2 c/o CT-MFD.21 1SVR500020R1100 0.065 (0.143) - 1 c/o CT-ERD.12 1SVR500100R0000 0.060 (0.132) - 2 c/o CT-ERD.22 1SVR500100R0100 0.065 (0.143) M 1 c/o CT-AHD.12 1SVR500110R0000 0.060 (0.132) M 2 c/o CT-AHD.22 1SVR500110R0100 0.065 (0.143) CT-VWD.12 1SVR500130R0000 OFF-delay ImpulseON 2CDC 251 091 F0006 Flasher starting with ON 7 (0.05 s 100 h) - 24-240 V AC 24-48 V DC - Pulse generator 2×7 (0.05 s 100 h) Star-delta changeover 4 (0.05 s 10 min) 1) 2) 3) 4) A ON-delay B OFF-delay CA Impulse-ON CB Impulse-OFF DA Flasher starting with ON DB Flasher staring with OFF H Pulse former ED Pulse generator F Star-delta change-over Type Order code Price Weight (1 pce) 1 pce kg (lb) ON-delay CT-MFD.12 CT-ERD.22 Output 1 c/o M M - 2 c/o 2 c/o 0.060 (0.132) CT-EBD.12 1SVR500150R0000 CT-TGD.122) 1SVR500160R0000 0.060 (0.132) CT-TGD.222) 1SVR500160R0100 0.065 (0.143) CT-SDD.223) 1SVR500211R0100 CT-SAD.22 1SVR500210R0100 4) 0.065 (0.143) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, Flasher starting with ON, Flasher starting with OFF, Pulse former ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h M Control input with voltage-related triggering Transition time 50 ms fixed - no triggering Transition time adjustable Synonyms used expression alternative expression(s) used expression alternative expression(s) 1 c/o contact SPDT voltage-related wet / non-floating 2 c/o contacts DPDT volt-free dry / floating 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/8 1 CT-D range Function diagrams Remarks Legend Function of the yellow LED The yellow LED R glows as soon as the output relay energizes and turns off when the output relay de-energizes. G B Control supply voltage not applied / Output contact open Control supply voltage applied / Output contact closed A1-Y1/B1 Control input with voltage-related triggering Terminal designations on the device and in the diagrams The 1st c/o contact is always designated 15-16/18. The 2nd c/o contact is designated 25-26/28. The n/o contacts of the star-delta timers are designated with 17-18 and 17-28. Control supply voltage is always applied to terminals A1-A2. ON-delay (Delay on make) CT-ERD, CT-MFD B A1-A2 15-18, 25-28 15-16, 25-26 green LED t10 % of the minimum rated control supply voltage U s Input circuit - Control circuit Control input, control function A1-Y1/B1 Kind of triggering Resistance to reverse polarity Parallel load / polarized Maximum cable length to the control inputs Minimum control pulse length Control voltage potential Current consumption of the control input Timing circuit Time ranges 7 time ranges 0.05 s - 100 h 4 time ranges 0.05 s - 10 min (CT-SDD, CT-SAD) Recovery time Accuracy within the rated control supply voltage tolerance Accuracy within the temperature range Repeat accuracy (constant parameters) Setting accuracy of time delay IEC/EN 61812-1 Star-delta transition time CT-SDD / CT-SAD Star-delta transition time tolerance Indication of operational states Control supply voltage / timing CT-SDD / CT-SAD 12-240 V AC/DC start timing external voltage-related triggering yes yes / yes 50 m ‑ 100 pF/m 20 ms see rated control supply voltage see data sheet 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min 5.) 5-100 min 6.) 0.5-10 h 7.) 5-100 h 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min < 50 ms it < 0.005 % / V it < 0.06 % / °C it < ± 0.5 % ± 10% of full-scale value fixed 50 ms / adjustable: 20 ms, 30 ms, 40 ms, 50 ms, 60 ms, 80 ms or 100 ms ±3 ms U: green LED V : control supply voltage applied W : timing R: yellow LED V : output relay energized Relay energized (1 c/o contact / 2 c/o contacts or inst. contact) Operating elements and controls Adjustment of the time range Fine adjustment of the time value Preselection of the timing function at multifunction devices Adjustment of the transition time CT-SAD Output circuit Kind of output 15-16/18 15-16/18; 25-26/28 17-18; 17-28 Contact material Rated operational voltage U e Minimum switching voltage / minimum switching current Maximum switching voltage / maximum switching current Rated operational current I e AC-12 (resistive) at 230 V (IEC/EN 60947-5-1 ) AC-15 (inductive) at 230 V DC-12 (resistive) at 24 V DC-13 (inductive) at 24 V AC rating (UL 508) utilization category (Control Circuit Rating Code) max. rated operational voltage Maximum continuous thermal current at B300 Maximum continuous thermal current at C300 max. making/breaking apparent power at B300 max. making/breaking apparent power at C300 Mechanical lifetime Electrical lifetime Max. fuse rating to achieve short-circuit protection n/c contact (IEC/EN 60947-5-1) n/o contact 1/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 front-face front-face front-face front-face rotary switch, direct reading scales potentiometer rotary switch, direct reading scales potentiometer Relay, 1 c/o contact AgNi alloy, Cd free 250 V Relay, 2 c/o contacts Relay, 2 n/o contacts (CT-SDD, CT-SAD) 12 V / 100 mA 250 V AC / 6 A 250 V AC / 5 A 6A 5A 3A 3A 6A 5A 2A 2A B 300 300 V AC 5A 3600 VA / 360 VA 30 x 10 6 switching cycles 0.1 x 10 6 switching cycles 6 A fast-acting 10 A fast-acting n/o: 3 A n/c: 0.75 A 1A n/o: B 300 n/c: C 300 n/o: n/c: n/o: n/c: 5A 2.5 A 3600/360 VA 1800/180 VA 6 A fast-acting CT-D range Technical data CT-D with 1 c/o contact CT-D with 2 c/o contacts CT-MFD.21 General data Mean time between failures (MTBF) Duty time Dimensions (W x H x D) Weight Mounting Mounting position Minimum distance to other units Degree of protection Electrical connection Wire size Stripping length Tightening torque Environmental data Ambient temperature range Climatic class Relative humidity range Shock (half-sine) Isolation data Rated impulse withstand voltage U imp between all isolated circuits Pollution category Overvoltage category Rated insulation voltage U i on request 100% 17.5 x 70 x 58 mm 17.5 x 80 x 58 mm (0.69 x 2.76 x 2.28 in) (0.69 x 3.15 x 2.28 in) see ordering details DIN rail (IEC/EN 60715), snap-mounting without any tool any horizontal / vertical no / no housing / terminals IP50 / IP20 fine-strand with(out) wire end ferrule 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG) rigid 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) 1 x 0.5-4 mm 2 (1 x 20-12 AWG) 7 mm (0.28 in) 0.5-0.8 Nm (4.43-7.08 lb.in) operation / storage -20 ... +60 °C / -40 ... +85 °C IEC/EN 60068-2-30 3K3 25-85% IEC/EN 60068-2-27 150 m/s 2, 11 ms IEC/EN 60664-1 type test: 4 kV; 1.2/50 µs IEC/EN 60664-1 IEC/EN 60664-1 input circuit / output circuit output circuit 1 / output circuit 2 input circuit / output circuit input circuit / output circuit Basic insulation (IEC/EN 61140) Protective separation (IEC/EN 61140, EN 50178) Power-frequency withstand voltage test between all isolated circuits (test voltage) Standards Product standard Low Voltage Directive EMC Directive RoHS Directive Electromagnetic compatibility Interference immunity to electrostatic discharge IEC/EN 61000-4-2 radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 electrical fast transient / burst IEC/EN 61000-4-4 surge IEC/EN 61000-4-5 conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Interference emission high-frequency radiated IEC/CISPR 22, EN 55022 high-frequency conducted IEC/CISPR 22, EN 55022 „Approvals and marks“ see page 1/4. 3 III 300 V not available 300 V 250 V 300 V 300 V routine test: 2.5 kV; 50 Hz; 1 s type test: 2.5 kV; 50 Hz; 60 s IEC/EN 61812-1 2006/95/EC 2004/108/EC 2011/65/EC IEC/EN 61000-6-1, IEC/EN 61000-6-2 Level 3 (6 kV / 8 kV) Level 3 (10 V / m) Level 3 (2 kV / 5 kHz) Level 4 (2 kV L-L) Level 3 (10 V) IEC/EN 61000-6-3, IEC/EN 61000-6-4 Class B Class B 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/14 1 CT-D range Technical data, Technical diagrams Technical diagrams Load limit curves resistive load AC current [A] DC current [A] resistive load AC current [A] 2CDC 252 121 F0206 AC voltage [V] resistive load DC voltage [V] CT-D.1x 2CDC 252 122 F0206 CT-D.1x DC current [A] CT-D.2x CT-D.2x 2CDC 252 124 F0206 1.0 0.9 0.8 0.7 250 V resistive load 0.6 0.5 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ 1/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Switching current [A] 2CDC 252 123 F0206 Contact lifetime Switching cycles Derating factor F for inductive AC load 0.1 2CDC 252 045 F0207 AC voltage [V] resistive load DC voltage [V] DC load (resistive) 2CDC 252 044 F0207 AC load (resistive) Derating factor F 1 CT-D range Wiring notes, Dimensional drawings Wiring notes for devices with control input A parallel load to the control input is possible A1 2CDC 252 102 F0b06 L(+) 1 Y1/B1 A2 N(-) dimensions in mm Dimensional drawings CT-D devices with 1 c/o contact or 2 n/o contacts 58 2.28“ 43,4 1.71“ 80 3.15“ 0.2“ 5 45 1.77“ 0.69“ 17,5 2CDC 252 130 F0b06 58 2.28“ 43,4 1.71“ 45 1.77“ 70 2.76“ 0.2“ 5 2CDC 252 131 F0b06 0.69“ 17,5 CT-D devices with 2 c/o contacts 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/16 CT-E range Product group picture 1 1/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CT-E range Table of contents CT-E Range Product group picture 1/17 Table of contents 1/18 Benefits and advantages 1/19 Ordering details 1/20 Function diagrams 1/22 Connection diagrams 1/27 Connection diagrams, Technical diagrams 1/28 Technical data 1/29 Wiring notes, Dimensional drawings 1/31 Notes 1/32 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/18 1 CT-E range Benefits and advantages Characteristics –– Diversity: –– 2 multifunction timers –– 56 single-function timers –– Control supply voltages: –– Dual range: 24 V AC/DC –– Single range: 110-130 V AC, 220-240 V AC –– Wide range: 24-240 V AC/DC (CT-MFE) –– Time ranges –– 5 single ranges: 0.05-1 s, 0.1-10 s, 0.3-30 s, 3-300 s, 0.3-30 min –– 8 time ranges: 0.05 s - 100 h (CT-MFE) –– Devices with 1 c/o (SPDT) contact (250 V / 4 A) or solid-state output for high switching frequencies (thyristor 0.8 A) –– Approvals / Marks (details see page 1/4) –– A, C, Benefits 1 Direct reading scales Direct setting of the time delay without any additional calculation provides accurate time delay adjustment. LEDs for status indication 2 All actual operational states are displayed by front-face LEDs, thus simplifying commissioning and troubleshooting. Connection screws in M3 (Pozidrive 1) 3 Easy and fast tightening and release of the connection screws with pozidrive, pan- or crosshead screwdriver. 4 Solid-state output Devices with solid-state output are the perfect solution for high operation cycles. R, K, E, L / a, b Synonyms used expression alternative expression(s) used expression alternative expression(s) 1 c/o contact SPDT voltage-related wet / non-floating 2 c/o contacts DPDT volt-free dry / floating Operating controls 1 2 3 1 LEDs for status indication U - green LED: V control supply voltage applied R2: red LED: V output relay energized 2 Time range adjustment (only multifunctional devices) 3 Fine adjustment of the time delay 4 Preselection of the timing function (only multifunctional devices) 4 A1 AL A1 AL 1/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 2CDC 252 166 F0005 3 2CDC 252 166 F0005 2 1SVC 110 000 F0506 1 1SVC 110 000 F0500 4 1SVC 110 000 F0508 1 CT-E range Ordering details Description The CT-E range with its excellent price/performance ratio offers an ideal solution for serial applications. 56 single-function devices with 5 different time ranges as well as 2 multifunction timers with 6 functions and 8 time ranges offer the highest possible flexibility for almost every application. For high operating cycles, contact-free CT-E timers with solid-state output are available. Ordering details Timing function Multifunctional 1) Rated control supply voltage 24-240 V AC/DC Time ranges 8 (0.05 s 100 h) Control Input Output M 1 c/o Type 1SVR 550 029 F8100 24 V AC/DC, 220-240 V AC CT-MFE 24 V AC/DC 0.3-30 s 3-300 s 1SVR550107R2100 1 c/o CT-ERE 1SVR 550 111 F1100 110-130 V AC 220-240 V AC CT-AHE 24 V AC/DC, 220-240 V AC OFF-delay2) 110-130 V AC A ON-delay B OFF-delay CA Impulse-ON CB Impulse-OFF DA Flasher starting with ON DB Flasher staring with OFF H Pulse former 24 V AC/DC, 220-240 V AC 0.1-10 s 1SVR550118R1100 0.3-30 s 1SVR550118R4100 3-300 s 1SVR550118R2100 0.3-30 s 1SVR550110R1100 M 1 c/o CT-AHE 1SVR550110R2100 0.1-10 s 1SVR550111R1100 0.3-30 s 1SVR550111R4100 3-300 s 1SVR550111R2100 0.1-10 s 1SVR550127R1100 0.1-10 s - 1 c/o CT-ARE 110-130 V AC 220-240 V AC 1SVR550127R4100 1SVR550120R1100 0.3-30 s 1SVR550120R4100 0.1-10 s 1SVR550137R1100 0.3-30 s 1SVR550137R4100 - 1 c/o CT-VWE 1SVR550137R2100 1SVR550130R1100 0.3-30 s 1SVR550130R4100 3-300 s 1SVR550130R2100 24 V AC/DC ImpulseOFF2) 1SVR550110R4100 3-300 s 0.3-30 s 0.08 (0.18) 1SVR550100R2100 1SVR550100R5100 0.1-10 s 110-130 V AC 1SVR550100R1100 0.3-30 min 3-300 s Impulse-ON 1SVR550107R5100 1SVR550100R4100 - 0.1-10 s OFF-delay 0.08 (0.18) 1SVR550107R4100 - 0.1-10 s 110-130 V AC 1SVR550029R8100 Weight (1 pce) kg (lb) 1SVR550107R1100 0.3-30 min ON-delay CT-MFE 3-300 s Price 1 pce 0.1-10 s 0.3-30 s Order code 0.08 (0.18) 0.08 (0.18) 0.08 (0.18) 1SVR550158R3100 0.05-1 s - 1 c/o CT-AWE 1SVR550150R3100 0.08 (0.18) 1SVR550151R3100 1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Flasher starting with ON, Flasher starting with OFF, Pulse former 2) without auxiliary voltage, True Off-delay timer M Control input with voltage-related triggering - no triggering 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/20 1 CT-E range Ordering details Bestellangaben 1 Timing function Rated control supplyvoltage 2CDC 251 125 F0004 24 V AC/DC ImpulseOFF CT-AWE 110-130 V AC 220-240 V AC 2CDC 251 059 F0003 Flasher staring with OFF CT-SDE Star-delta changeover twice ON-delayed 24 V AC/DC, 220-240 V AC Time ranges Control Input Output Type 0.1-10 s 0.3-30 s 1SVR550148R1100 1SVR550148R4100 3-300 s 1SVR550148R2100 0.1-10 s 0.3-30 s 1 c/o CT-AWE 1SVR550140R2100 0.1-10 s 0.3-30 s 1SVR550141R1100 3-300 s 1SVR550141R2100 24 V AC/DC, 220-240 V AC Star-delta change-over with impuls 110-130 V AC - 1 c/o CT-EBE 4) 24-240V AC/DC A ON-delay B OFF-delay CA Impulse-ON CB Impulse-OFF DA Flasher starting with ON DB Flasher staring with OFF H Pulse former FA Star-delta change-over twice 1SVR550207R1100 1SVR550207R4100 3-300 s - 1 c/o CT-YDE 1) 2) FC DE ON-delayed Star-delta change-over with impulse Pulse generator starting with ON or OFF 1SVR550200R4100 1SVR550200R2100 - 3) 4) 5) 6) 0.08 (0.18) 0.08 (0.18) 0.08 (0.18) 1 n/o + 1 n/c CT-SDE 2) 5) 1SVR550210R4100 0.08 (0.18) 1SVR550212R4100 0.1-10 s, 3-300 s CT-MKE - - 3) 6) solidestate 0.3-30 s 1SVR550019R0000 0.08 (0.18) 1SVR550509R1000 CT-EKE 1SVR550509R4000 0.08 (0.18) 1SVR550509R2000 1SVR550519R1000 - 3-300 s 2) kg (lb) 1SVR550217R4100 0.3-30 s 0.1-10 s 1) 1SVR550200R1100 3-300 s 24-240 V AC/DC 0.3-30 s 24-240 V AC 1SVR550207R2100 0.3-30 s 3-300 s OFF-delay 1SVR550167R1100 0.3-30 s 0.1-10 s ON-delay 1 pce 1SVR550160R1100 380-415 V AC Multifunctional 8) Weight (1 pce) 1SVR550141R4100 0.1-10 s 0.1-10 s 110-130 V AC 1SVR550140R4100 3-300 s 0.1-10 s Price 1SVR550140R1100 M 110-130 V AC 24 V AC/DC, 220-240 V AC Order code CT-AKE 1SVR550519R4000 0.08 (0.18) 1SVR550519R2000 without auxiliary voltage M Control input with voltage-related triggering with fixed transition time - no triggering solid-state output, functions and time range selection via external jumpers symetric ON & OFF times common contact Functions: ON-delay (AC/DC), Impuls-ON (AC only), Flasher starting with OFF (AC only) Notice CT-...KE are solid-state timers with thyristor output for 2-wire applications. They are connected directly in series with the control coil of contactors or relays. Voltage should not be applied without a load connected, because there is no current limiting in the unit. 1/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CT-E range Function diagrams Remarks Legend G Control supply voltage not applied / Output contact open B Control supply voltage applied / Output contact closed A1-Y1/B1: Control input with voltage-related triggering Terminal designations on the device and in the diagrams The c/o contact is always designated 15-16/18. The n/o contacts are designated with 15-16 and 15-18. Control supply voltage is always applied to terminals A1-A2/B1. Function of the red LED The red LED R glows as soon as the output relay energizes and turns off when the output relay de-energizes. ON-delay (Delay on make) CT-ERE, CT-MFE B A1-A2/B1 15-18 15-16 green LED red LED t U and/or I and/or I and U and I for overcurrent 2 Adjustment of the threshold value U for overvoltage 2 Adjustment of the threshold value I“ = 1115-1216/1418 ; “U“ = 1115-1216/1418 ; “ 10 A, lateral spacing has to be min. 10 mm 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/22 Current monitoring relays, single-phase Technical data - Current monitoring relays Type 2 CM-SRS.1 General data MTBF Duty time Dimensions (W x H x D) CM-SRS.2 CM-SRS.M CM-SFS.2 on request 100% product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in) packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in) Weight net weight depending on device, see ordering details gross weight depending on device, see ordering details Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units Material of housing Degree of protection Electrical connection Wire size Stripping length 10 mm (0.39 in) at measured current > 10 A UL 94 V-0 housing / terminals IP50 / IP20 Screw connection technology fine-strand with(out) wire end ferrule 1 2 rigid 1 2 8 Tightening torque x 0.5-2.5 mm 2 (1 x 20-14 AWG) x 0.5-1.5 mm 2 (2 x 20-16 AWG) x 0.5-4 mm 2 (1 x 20-12 AWG) x 0.5-2.5 mm 2 (2 x 20-14 AWG) mm (0.32 in) 0.6-0.8 Nm (5.31-7.08 lb.in) Environmental data Ambient temperature range Easy Connect Technology (Push-in) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) - operation / -20...+60 °C / -40...+85 °C storage 55 °C, 6 cycles Damp heat (IEC 60068-2-30) Vibration (sinusoidal) (IEC/EN 60255-21-1) Class 2 Shock (IEC/EN 60255-21-2) Class 2 Isolation data Rated insulation voltage (VDE 0110, IEC 60947-1, IEC/EN 60255-5) 2) supply / 600 V measuring c ircuit / output supply / output 1/2 250 V Rated impulse withstand supply /measuring 6 kV 1.2/50 µs circuit / output voltage U imp (IEC/EN 60947-1, supply / output 1/2 4 kV 1.2/50 µs IEC/EN 60255-5) Pollution degree (VDE 0110, IEC 664, IEC/EN 60255-5) 3 Overvoltage category (VDE 0110, IEC 664, IEC/EN 60255-5) III Standards Product standard IEC/EN 60255-1, IEC/EN 60255-27, EN 50178 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 radiated, radio-frequency, electromagnetic field electrical fast transient / burst IEC/EN 61000-4-3 Level 3 IEC/EN 61000-4-4 Level 3 surge IEC/EN 61000-4-5 Level 3 conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3 Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22; EN 55022 Class B high-frequency conducted IEC/CISPR 22; EN 55022 Class B 2/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Voltage monitoring relays, single-phase Technical data - Voltage monitoring relays Type CM-ESS.1 Input circuit - Supply circuit Rated control supply voltage U s Current / power consumption Power failure buffering time Transient overvoltage protection Input circuit - Measuring circuit Monitoring function Measuring method Measuring inputs 2 AC versions 50/60 Hz AC/DC versions 50/60 Hz or DC see data sheet 20 ms Varistors B-C over- or undervoltage monitoring configurable Terminal connection Measuring range AC/DC Input resistance Pulse overload capacity t < 1 s Continous capacity CM-ExS B-C B-C B-C 3-30 V 6-60 V 30-300 V 600 kq 600 kq 600 kq 800 V 800 V 800 V 660 V 660 V 660 V adjustable within the indicated measuring range 10 % 3-30 % adjustable DC / 15 Hz - 2 kHz DC / 50-60 Hz AC: 80 ms / DC: 120 ms U m 0.5 % U m 0.06 % / °C Varistors none B-C 60-600 V 600 kq 800 V 660 V 5 % fixed 0 or 0.1-30 s adjustable w0.07 % of full scale t m 0.5 % t m 0.06 % / °C V: W: U: red LED V : W: R: yellow LED V : Z: Y: control supply voltage applied tripping delay T V active overvoltage, undervoltage relay energized, no latching function relay energized, active latching function relay de-energized, active latching function Output circuits Kind of output 1 c/o contact 2 c/o contacts Operating principle open-circuit principle 1) Contact material Rated operational voltage U e over- and undervoltage monitoring configurable True RMS measuring principle Repeat accuracy (constant parameters) Accuracy within the control supply voltage tolerance Accuracy within the temperature range Indication of operational states Control supply voltage U/T: green LED Relay status CM-EFS.2 A1-A2 110-130 V AC A1-A2 220-240 V AC A1-A2 24-240 V AC/DC -15...+10 % Threshold value(s) Setting accuracy of threshold value Hysteresis related to the threshold value Measuring signal frequency range Rated measuring signal frequency range Maximum response time Accuracy within the control supply voltage tolerance Accuracy within the temperature range Transient overvoltage protection Timing circuit Delay time T V Measured value CM-ESS.M A1-A2 Rated control supply voltage U s tolerance Rated frequency CM-ESS.2 1x2 c/o contacts or 2x1 c/o contact configurable open- or closed-circuit principle configurable 1) AgNi IEC/EN 60947-1 250 V Minimum switching voltage / minimum switching current Maximum switching voltage / maximum switching current Rated o perational current AC-12 (resistive) at 230 V I e (IEC/EN 60947-5-1) AC-15 (inductive) at 230 V DC-12 (resistive) at 24 V DC-13 (inductive) at 24 V AC rating Utilization category (Control Circuit Rating Code) (UL 508) max. rated operational voltage max. continuous thermal current at B 300 max. making/breaking apparent power (Make/Break) at B 300 Mechanical lifetime Electrical lifetime AC-12, 230 V, 4 A Max. fuse rating to achieve shortn/c contact circuit protection n/o contact 24 V / 10 mA 250 V AC / 4 A AC 4A 3A 4A 2A B 300 300 V AC 5A 3600/360 VA 30x10 6 switching cycles 0.1x10 6 switching cycles 6 A fast-acting 10 A fast-acting 10 A fast-acting 6 A fast-acting 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/24 Voltage monitoring relays, single-phase Technical data - Voltage monitoring relays Type General data 2 CM-ESS.1 MTBF Duty time Dimensions (W x H x D) Weight Mounting Mounting position Minimum distance to other units Material of housing Degree of protection Environmental data product dimensions packaging dimensions net weight gross weight Ambient temperature ranges Damp heat, cyclic (IEC/EN 60068-2-30) Vibration, sinusoidal (IEC/EN 60255-21-1) Shock (IEC/EN 60255-21-2) Electrical connection Wire size Stripping length Tightening torque Isolation data vertical / horizontal housing / terminals CM-ESS.2 CM-EFS.2 on request 100% 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in) 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in) depending on device, see ordering details depending on device, see ordering details DIN rail (IEC/EN 60715), snap-on mounting without any tool any not necessary / not necessary UL 94 V-0 IP50 / IP20 operation -20...+60 °C storage -40...+85 °C 55 °C, 6 cycle Class 2 Class 2 Screw connection technology fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG) 2 x 0.5-2.5 mm 2 (2 x 20-14 AWG) 8 mm (0.32 in) 0.6-0.8 Nm (5.31-7.08 lb.in) Rated insulation voltage (VDE 0110, IEC 60947-1, IEC/EN 60255-5) Rated impulse withstand voltage U imp (IEC/EN 60947-1, IEC/EN 60255-5) supply / measuring circuit / output supply / output 1/2 supply / measuring circuit / output supply / output 1/2 Pollution degree (VDE 0110, IEC 664, IEC/EN 60255-5) Overvoltage category (VDE 0110, IEC 664, IEC/EN 60255-5) Standards Product standard Low Voltage Directive EMC Directive Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field CM-ESS.M Easy Connect Technology (Push-in) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) - 600 V 250 V 6 kV 1.2/50 µs 4 kV 1.2/50 µs 3 III IEC/EN 60255-1, IEC/EN 60255-27, EN 50178 2006/95/EC 2004/108/EC IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 3 IEC/EN 61000-4-3 Level 3 electrical fast transient / burst IEC/EN 61000-4-4 surge IEC/EN 61000-4-5 conducted disturbances, induced by IEC/EN 61000-4-6 radio-frequency fields Interference emission high-frequency radiated IEC/CISPR 22; EN 55022 high-frequency conducted IEC/CISPR 22; EN 55022 Level 3 Level 3 Level 3 IEC/EN 61000-6-3 Class B Class B 1) Open-circuit principle: output relay energizes if the measured value exceeds d / falls below c the adjusted threshold value Closed-circuit principle: output relay de-energizes if measured value exeeds d / falls below c the adjusted threshold value 2/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Current and voltage monitoring relays, single-phase Notes 2 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/26 Three-phase monitoring relays Product group picture 2 2/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Three-phase monitoring relays Table of contents Three-phase monitoring relays Benefits and advantages, Applications 2/29 Operating controls 2/30 Selection table singlefunctional 2/31 Selection table multifunctional 2/32 Ordering details - Singlefunctional 2/33 Ordering details - Multifunctional 2/34 Function diagrams 2/35 Connection diagrams 2/39 DIP switches, Rotary switches 2/40 Technical data 2/41 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/28 2 Three-phase monitoring relays Benefits and advantages, Applications 2 Characteristics of the CM range three-phase monitors –– Adjustable phase unbalance threshold value 1) – – Adjustable ON-delay/OFF-delay time 1) – – Dual frequency measuring 50/60 Hz – – Powered by the measuring circuit – – 1 n/o contact, 1 or 2 c/o contacts – – LEDs for the indication of operational states – – Multifunctional and single-functional devices – – Phase failure detection – – Phase sequence monitoring 1) – – Over- and undervoltage monitoring (fixed or adjustable)1) –– Wide-range operating voltage guarantees world-wide operation –– Approvals / Marks AC RK E 1) 2) 2) / a b depending on device type Applicable in rail application following the latest standards for rail applications: NF F 16-101/102 (I2/F2 classified), EN 45545 (Hazard Level 3), DIN 5510, EN 50155, IEC 60571. Further information is available in our rail segment brochure 2CDC110084B0201. Phase unbalance monitoring If the supply by the three-phase system is unbalanced due to uneven distribution of the load, the motor will convert a part of the energy into reactive power. This energy gets lost unexploited; also the motor is exposed to higher thermal stress. Other thermal protection devices fail to dete ct continuing unbalances which can lead to damage or destruction of the motor. The CM range three-phase monitors with phase unbalance monitoring can reliably detect this critical situation. Phase sequence Changing the phase sequence during operation or a wrong phase sequence prior to startup causes a change of the rotational direction of the connected device. Generators, pumps or fans rotate in the wrong direction and the installation is no longer working properly. Especially for moveable equipment, such as construction machinery, phase sequence detection prior to the startup process is highly reasonable. Phase loss In case of phase loss, undefined stats of the installation are likely to occur. E.g. the startup process of motors is disturbed. All three-phase monitors of the ABB CM range detect a phase loss as soon as the voltage of one phase drops below 60% of its nominal value. Extended functionality ABB’s new generation of three-phase monitoring relays feature additional functions making the application field for the devices considerably larger. Selectable phase sequence monitoring The phase sequence monitoring can be switched off by means of a rotary switch or a DIP switch. This enables monitoring of three-phase mains where phase sequence is not relevant for the application, for example in case of motors with forward and reverse rotation, heating applications, etc. Automatic phase sequence correction The automatic phase sequence correction is activated by means of a DIP switch. With activated phase sequence correction, it is ensured that for any non-fixed or portable equipment, e.g. construction machinery, the correct phase sequence is always applied to the input terminals of the load. For details regarding the wiring, please see function description / diagrams. Structure of the type designation CM-_ _ x.yz x: width of enclosure y: Control supply voltage / measuring range 1 2 3 4 5 6 7 8 110, 115, 120, 127 V supply systems (phaseneutral) 220, 230, 240 V supply systems (phase-neutral) 200, 208, 220, 230, 240, 257, 260 V supply systems (phase-phase) 440, 460 V supply systems (phase-phase) 480, 500 V supply systems (phase-phase) 575, 600 V supply systems (phase-phase) 660, 690 V supply systems (phase-phase) 200, 400 V supply systems (phase-phase) z: Rated frequency / output circuit 1 2 3 Voltage monitoring All electric devices can be damaged when operated continuously in a network with out-of-range voltages. For example, safe starting is not ensured in case of undervoltage. Also, the switching state of a contactor is not clearly defined when operated in a „forbidden“ voltage range. This can lead to undefined states of the installtion and cause damage or destruction of valuable parts. 2/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 50/60 Hz – 1x2 c/o 50/60 Hz – 1x2 or 2x1 c/o 50/60/400 Hz – 1x2 oder 2x1 c/o Three-phase monitoring relays Operating controls S-Range Housing 1 Adjustment of the hysteresis >U for overvoltage 2 Adjustment of the threshold value U for overvoltage 2 Adjustment of the threshold value Asym. for phase unbalance 3 Indication of operational states R/T: red LED – Relay status / timing F1: yellow LED – Fault message F2: yellow LED – Fault message 1 2 4 Adjustment of the tripping delay Tv 5 Adjustment of the hysteresis 60% is expected, we recommend to use our three-phase monitoring relays for unbalance CM-PAS.xx S: screw connection P: push-in / easy connect 2/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Three-phase monitoring relays Ordering details - Multifunctional Ordering details Rated control DIP Monitoring supply voltage switch function = measuring voltage Neutral Type monitoring 90-170 V AC 2CDC 251 065 V0011 180-280 V AC 3x160-300 V AC A B k l CM-MPS.23P Multifunctional (Three-phase phase failure detection, Phase sequence monitoring, overvoltage, undervoltage, Phase unbalance) n 3x300-500 V AC 180-280 V AC 3x300-500 V AC A B k l m n i j 2CDC 251 062 V0011 3x350-580 V AC 3x450-720 V AC CM-MPN.52P A B k l m n i j Order code Price 1 pce Weight (1 pce) kg (lb) CM-MPS.11S 1SVR730885R1300 0.148 (0.326) CM-MPS.11P 1SVR740885R1300 0.137 (0.302) CM-MPS.21S 1SVR730885R3300 0.146 (0.322) CM-MPS.21P 1SVR740885R3300 0.135 (0.298) CM-MPS.31S 1SVR730884R1300 0.142 (0.313) CM-MPS.31P 1SVR740884R1300 0.133 (0.293) CM-MPS.41S 1SVR730884R3300 0.140 (0.309) CM-MPS.41P 1SVR740884R3300 0.132 (0.291) CM-MPS.23S 1SVR730885R4300 0.149 (0.328) CM-MPS.23P 1SVR740885R4300 0.138 (0.304) CM-MPS.43S 1SVR730884R4300 0.148 (0.327) CM-MPS.43P 1SVR740884R4300 0.137 (0.302) CM-MPN.52S 1SVR750487R8300 0.230 (0.507) CM-MPN.52P 1SVR760487R8300 0.226 (0.498) CM-MPN.62S 1SVR750488R8300 0.229 (0.505) CM-MPN.62P 1SVR760488R8300 0.225 (0.496) CM-MPN.72S 1SVR750489R8300 0.224 (0.494) CM-MPN.72P 1SVR760489R8300 0.220 (0.485) n Multifunctional (Three-phase phase failure detection, Phase sequence monitoring, overvoltage, undervoltage, Phase unbalance) 3x530-820 V AC A B k l m n i j ON-delayed OFF-delayed Phase sequence monitoring activated Phase sequence monitoring deactivated Phase sequence correction activated Phase sequence correction deactivated 2x1 c/o (SPDT) contacts 1x2 c/o (SPDT) contacts S: screw connection P: push-in / easy connect 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/34 2 Three-phase monitoring relays Function diagrams L1, L2, L3, N Measuring value L1, L2, L3, N L1, L2, N t s L1, L2, L3, N L2, L3, N L1, L2, L3, N L3 L1 t N U >U-5% Measuring value U >U-5% Measuring value U >U-5% Measuring value U >U-5% Measuring value 400 V > 400 V > 220 V > 400 V > 220 V > 400 V Material of housing UL 94 V-0 Degree of protection housing / terminals IP50 / IP20 Electrical connection Wire size Screw connection technology Easy Connect Technology (Push-in) fine-strand with(out) wire end 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG) ferrule 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG) 2 x 0.5-2.5 mm 2 (2 x 20-14 AWG) 8 mm (0.32 in) 0.6-0.8 Nm (5.31-7.08 lb.in) Stripping length Tightening torque Environmental data Ambient temperature ranges operation / storage Damp heat (IEC 60068-2-30) Climatic category Vibration (sinusoidal) (IEC/EN 60255-21-1) Shock (IEC/EN 60255-21-2) Isolation data Rated insulation input circuit / output circuit voltage U i output circuit 1 / output circuit 2 Rated impulse withstand voltage input circuit U imp (VDE 0110, IEC/EN 60664) output circuit Test voltage between all isolated circuits (routine test) Basic insulation input circuit / output circuit Protective separation (VDE 0106 input circuit / part 101 and 101/A, IEC/EN 1140) output circuit Pollution degree (VDE 0110, IEC/EN 60664) Overvoltage category (VDE 0110, IEC 60664) Standards Product standard Low Voltage Directive EMC directive RoHS directive Electromagnetic compatibility Interference immunity to electrostatic discharge IEC/EN 61000-4-2 radiated, radio-frequency, IEC/EN 61000-4-3 electromagnetic field electrical fast transient / IEC/EN 61000-4-4 burst surge IEC/EN 61000-4-5 conducted disturbances, IEC/EN 61000-4-6 induced by radiofrequency fields Interference emission high-frequency radiated IEC/CISPR 22, EN 55022 high-frequency conducted IEC/CISPR 22, EN 55022 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) - -25...+60 °C / -40...+85 °C 55 °C, 6 cycles 3K3 Class 2 Class 2 600 V 300 V 6 kV; 1.2/50 µs 4 kV; 1.2/50 µs 2.5 kV, 50 Hz, 1 s 600 V 3 III IEC/EN 60255-6, EN 50178 2006/95/EC 2004/108/EC 2011/65/EC EN 61000-6-1, EN 61000-6-2 Level 3 (6 kV / 8 kV) Level 3 (10 V/m) Level 3 (2 kV / 2 kHz) Level 4 (2 kV L-L) Level 3 (10 V) EN 61000-6-3, EN 61000-6-4 Class B Class B 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/44 2 Three-phase monitoring relays Technical data Type 2 CM-MPS.11 CM-MPS.21 Input circuit = Measuring circuit Rated control supply voltage U S = measuring voltage L1, L2, L3, N 3x90-170 V AC 3x180-280 V AC Rated control supply voltage U S tolerance -15...+10 % Rated frequency Frequency range Typical current / power consumption 50/60 Hz 45-65 Hz 25 mA / 10 VA 25 mA / 18 VA (115 V AC) (230 V AC) L1, L2, L3, N J J can be switched off J J Measuring circuit Monitoring functions Phase failure Phase sequence Automatic phase sequence correction Over- / undervoltage Phase unbalance J J Interrupted neutral J J Measuring range Overvoltage 3x120-170 V AC 3x240-280 V AC Undervoltage 3x90-130 V AC 3x180-220 V AC Phase unbalance 2-25 % of average of phase voltages Thresholds Overvoltage adjustable within measuring range Undervoltage adjustable within measuring range Phase unbalance (switch-off value) adjustable within measuring range Hysteresis related to the Over- / undervoltage fixed 5 % threshold value Phase unbalance fixed 20 % Rated frequency of the measuring signal 50/60 Hz Frequency range of the measuring signal 45-65 Hz Maximum measuring cycle time 100 ms Accuracy within the rated control supply voltage tolerance U 0.5 % Accuracy within the temperature range U 0.06 % / °C Measuring method True RMS Timing circuit Start-up delay t S fixed 200 ms CM-MPS.31 25 mA / 10 VA (230 V AC) J J J - J - 3x220-300 V AC 3x160-230 V AC 3x420-500 V AC 3x300-380 V AC ON- or OFF-delay 0; 0.1-30 s adjustable Accuracy within the rated control supply voltage tolerance Accuracy within the temperature range Indication of operational states Output circuits Kind of output Operating principle Contact material Rated operational voltage U e (IEC/EN 60947-1) t 0.5 % t 0.06 % / °C Details see function description / -diagrams 15-16/18, 25-26/28 relay, 1 x 2 c/o contacts closed-circuit principle 1) AgNi alloy, Cd free 250 V Minimum switching power Maximum switching voltage Rated operational current I e (IEC/EN 60947-5-1) 24 V / 10 mA see „Load limit curves“ on page 127 4A 3A 4A 2A B 300 1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value 2/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 25 mA / 18 VA (400 V AC) L1, L2, L3 J J Tripping delay t V AC-12 (resistive) 230 V AC-15 (inductive) 230 V DC-12 (resistive) 24 V DC-13 (inductive) 24 V AC rating (UL 508) Utilization category (Control Circuit Rating Code) max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5 A max. making/breaking 3600/360 VA apparent power at B 300 Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 10 6 switching cycles Max. fuse rating to achieve short-circuit n/c contact 6 A fast-acting protection n/o contact 10 A fast-acting CM-MPS.41 L1, L2, L3 3x160-300 V AC 3x300-500 V AC Three-phase monitoring relays Technical data Type CM-MPS.11 General data MTBF CM-MPS.21 CM-MPS.31 CM-MPS.41 on request Duty time 100% Dimensions (W x H x D) 2 product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in) packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in) Weight Screw connection technology Easy Connect Technology (Push-in) net weight depending on device, see ordering details gross weight depending on device, see ordering details Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units horizontal 10 mm (0.39 in) in case of continuous measuring voltages > 120 V > 240 V > 220 V UL 94 V-0 Material of housing Degree of protection Electrical connection Wire size > 400 V housing / terminals IP50 / IP20 Screw connection technology fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG) 2 x 0.5-2.5 mm 2 (2 x 20-14 AWG) 8 mm (0.32 in) 0.6-0.8 Nm (5.31-7.08 lb.in) Stripping length Tightening torque Environmental data Ambient temperature ranges operation / storage Damp heat (IEC 60068-2-30) Climatic category Vibration (sinusoidal) (IEC/EN 60255-21-1) Shock (IEC/EN 60255-21-2) Isolation data Rated insulation v oltage input circuit / output circuit Ui output circuit 1 / output circuit 2 Rated impulse withstand voltage U imp (VDE 0110, IEC/EN 60664) - -25...+60 °C / -40...+85 °C 55 °C, 6 cycles 3K3 Class 2 Class 2 600 V 300 V output circuit 4 kV; 1.2/50 µs 2.5 kV, 50 Hz, 1 s input circuit / output circuit 600 V Protective separation (VDE 0106 part input circuit / output yes 101 and 101/A, IEC/EN 61140) circuit Pollution degree (VDE 0110, IEC/EN 60664) 3 Overvoltage category (VDE 0110, IEC 60664) III Standards Product standard IEC/EN 60255-1, EN 50178 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC RoHS directive 2011/65/EC Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient / burst surge conducted disturbances, induced by radio-frequency fields harmonics and interharmonics Interference emission high-frequency radiated high-frequency conducted 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) input circuit 6 kV; 1.2/50 µs Test voltage between all isolated circuits (routine test) Basic insulation Easy Connect Technology (Push-in) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) - EN 61000-6-1, EN 61000-6-2 IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV) IEC/EN 61000-4-3 Level 3 (10 V/m) IEC/EN 61000-4-4 Level 3 (2 kV / 2 kHz) IEC/EN 61000-4-5 Level 4 (2 kV L-L) IEC/EN 61000-4-6 Level 3 (10 V) IEC/EN 61000-4-13 Class 3 EN 61000-6-3, EN 61000-6-4 IEC/CISPR 22, EN 55022 Class B IEC/CISPR 22, EN 55022 Class B 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/46 Three-phase monitoring relays Technical data Type CM-MPS.23 L1, L2, L3, N Input circuit = Measuring circuit Rated control supply voltage U S = measuring voltage 2 3x180-280 V AC -15...+10 % Rated control supply voltage U S tolerance Rated frequency Frequency range Typical current / power consumption Measuring circuit Monitoring functions Measuring range Phase failure Phase sequence Automatic phase sequence correction Over- / undervoltage Phase unbalance Interrupted neutral Overvoltage Undervoltage CM-MPS.43 3x300-500 V AC CM-MPN.52 CM-MPN.62 L1, L2, L3 3x350-580 V AC 3x450-720 V AC Start-up delay t S1 fixed 250 ms Tripping delay t V ON- or OFF-delay 0; 0.1-30 s adjustable Accuracy within the rated control supply voltage tolerance Accuracy within the temperature range Indication of operational states Output circuits Kind of output Operating principle Contact material Rated operational voltage U e IEC/EN 60947-1 Minimum switching power Maximum switching voltage Rated operational current I e AC-12 (resistive) 230 V (IEC/EN 60947-5-1) AC-15 (inductive) 230 V DC-12 (resistive) 24 V DC-13 (inductive) 24 V AC rating (UL 508) Utilization category (Control Circuit Rating Code) max. rated operational voltage max. continuous thermal current at B 300 max. making/breaking apparent power at B 300 Mechanical lifetime Electrical lifetime (AC-12, 230 V, 4 A) Max. fuse rating to achieve shortn/c contact circuit protection n/o contact t 0.5 % t 0.06 % / °C Details see function description / -diagrams 15-16/18, 25-26/28 relay, 2 x 1 or 1 x 2 c/o contacts configurable closed-circuit principle 1) AgNi alloy, Cd free 250 V 24 V / 10 mA see „Load limit curves“ on page 127 4A 3A 4A 2A B 300 1) 3x530-820 V AC 50/60/400 Hz 50/60 Hz 45-440 Hz 45-65 Hz 5 mA / 4 VA 5 mA / 4 VA 29 mA / 41 VA 29 mA / 52 VA 29 mA / 59 VA (230 V AC) (400 V AC) (480 V AC) (600 V AC) (690 V AC) L1, L2, L3, N L1, L2, L3 J J J J J can be switched off configurable J J J J J J J J J J J 3x240-280 3x420-500 3x480-580 3x600-720 3x690-820 V AC V AC V AC V AC V AC 3x180-220 3x300-380 3x350-460 3x450-570 3x530-660 V AC V AC V AC V AC V AC 2-25 % of average of phase voltages adjustable within measuring range adjustable within measuring range adjustable within measuring range fixed 5 % fixed 20 % 50/60/400 Hz 50/60 Hz 45-440 Hz 45-65 Hz 100 ms U 0.5 % U 0.06 % / °C True RMS Phase unbalance Overvoltage Undervoltage Phase unbalance (switch-off value) Hysteresis related to Over- / undervoltage the threshold value Phase unbalance Rated frequency of the measuring signal Frequency range of the measuring signal Maximum measuring cycle time Accuracy within the rated control supply voltage tolerance Accuracy within the temperature range Measuring method Timing circuit Start-up delay t S and t S2 fixed 200 ms Thresholds CM-MPN.72 300 V AC 5A 3600/360 VA 30 x 10 6 switching cycles 0,1 x 10 6 switching cycles 6 A fast-acting 10 A fast-acting 10 A fast-acting Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value 2/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Three-phase monitoring relays Technical data Type General data MTBF Duty time Dimensions (W x H x D) CM-MPS.23 product dimensions packaging dimensions CM-MPS.43 CM-MPN.52 CM-MPN.62 CM-MPN.72 on request 100% 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in) 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in) depending on device, see ordering details DIN rail (IEC/EN 60715), snap-on mounting without any tool any not necessary / not necessary UL 94 V-0 IP50 / IP20 Weight Mounting Mounting position Minimum distance to other units vertical / horizontal Material of housing Degree of protection housing / terminals Electrical connection Wire size Screw connection technology Easy Connect Technology (Push-in) fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) 2 x 0.5-2.5 mm 2 (2 x 20-14 AWG) Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) Environmental data Ambient temperature ranges operation / storage -25...+60 °C / -40...+85 °C Damp heat (IEC 60068-2-30) 55 °C, 6 cycles Climatic category 3K3 Vibration (sinusoidal) (IEC/EN 60255-21-1) Class 2 Shock (IEC/EN 60255-21-2) Class 2 Isolation data Rated insulation v oltage U i input circuit / output 600 V 1000 V circuit output circuit 1 / 2 300 V Rated impulse withstand voltage U imp input circuit 6 kV; 1.2/50 µs 8 kV; 1.2/50 µs (VDE 0110, IEC/EN 60664) output circuit 4 kV; 1.2/50 µs Test voltage (routine isolated output circuits 2.5 kV, 50 Hz, 1 s test) between input circuit and isolated output circuits 2.5 kV, 50 Hz, 1 s 4 kV, 50 Hz, 1 s Basic insulation input circuit / output circuit 600 V 1000 V Protective separation (VDE 0106 part input circuit / 101 and 101/A, IEC/EN 61140) output circuit Pollution degree (VDE 0110, IEC/EN 60664) 3 Overvoltage category (VDE 0110, IEC 60664) III Standards Product standard IEC/EN 60255-1, EN 50178 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC RoHS directive 2011/65/EC Electromagnetic compatibility Interference immunity to EN 61000-6-1, EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV) radiated, radio-frequency, IEC/EN 61000-4-3 Level 3 (10 V/m) electromagnetic field electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 2 kHz) surge IEC/EN 61000-4-5 Level 4 (2 kV Level 4 (2 kV L-L) L-N) conducted disturbances, induced by IEC/EN 61000-4-6 Level 3 (10 V) radio-frequency fields harmonics and interharmonics IEC/EN 61000-4-13 Class 3 Interference emission EN 61000-6-3, EN 61000-6-4 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/48 2 Grid feeding monitoring relays Voltage and frequency monitoring functions Product group picture 2 2/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Grid feeding monitoring relays Voltage and frequency monitoring functions Table of contents Grid feeding monitoring relays - Voltage and frequency monitoring functions Benefits and advantages, operating controls 2/51 Applications 2/52 Applications, connection diagram 2/53 Ordering and selection 2/54 Technical data - CM-UFD.Mxx 2/55 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/50 2 Grid feeding monitoring relays Voltage and frequency monitoring functions Benefits and advantages, operating controls Characteristics CM-UFD.M22 – – ROCOF (rate of change of frequency) monitoring, configurable – – Third party certificate confirming accordance with CEI 0-21 – – Pre-setting according to CEI 0-21 Characteristics CM-UFD.M31 – – ROCOF (rate of change of frequency) monitoring and vector shift detection, configurable – – Third party certificate confirming accordance with VDE-AR-N 4105 and BDEW – – Pre-settings according to VDE-AR-N 4105 and BDEW Characteristics CM-UFD.M33 – – ROCOF (rate of change of frequency) monitoring and vector shift detection, configurable – – Factory certificate confirming accordance with Engineering Recommendation G59 Issue 3 - September 2013; Engineering Recommendation G83 Issue 2 - December 2012 – – Pre-setting according to G59/3 LV + G83/2 HV – – UL 508, CAN/CSA C22.2 No.14 CM-UFD.Mxx 1 1 Display R1 R2 R3 - relay status; in this case R3 is de-energized FB - status feedback loop Y0-Y1; in this case FB is closed EXT – status input external signal; in this case input is closed REM – status remote trip input; in this case input is closed 2 2 Indication of operational states U/T: green LED – supply voltage applied / flashing = timing active F: red LED - failure 3 3 Keypad 2CDC 253 020 F0013 2 Characteristics for all CM-UFD devices –– Monitoring of voltage and frequency in single- and threephase mains 2-wire, 3-wire or 4-wire –– Over- and undervoltage, 10 minutes average value as well as over- and underfrequency monitoring –– Two-level threshold settings for over-/undervoltage and frequency –– Multiline, backlit LCD display –– All threshold values adjustable as absolute values –– True RMS measuring principle –– High measurement accuracy –– 3 control inputs for remote trip, feedback signal, and external signal –– Tripping delay for each threshold adjustable –– Interrupted neutral detection –– Error memory for up to 99 entries (incl. cause of error, measured value, relative timestamp) –– Test function –– Password setting protection –– 3 c/o (SPDT) contacts –– LEDs for the indication of operational states 2/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 ESC: escape / return to previous menu ^: up / value increase ∨ : down / value decrease OK: enter / confirm selection Grid feeding monitoring relays Voltage and frequency monitoring functions Applications Example of single-phase application CM-UFD.M22 Example of three-phase application CM-UFD.M22 9 N 230 V AC L1 N CP-E 24/X 11 L+ L- 1 24 V DC L+IN L-IN CP-B 24/X L L N 2CDC 252 004 F0014 L 12 L+OUT L-OUT 13 N L1 N CP-E 24/X 230 V AC 8 11 L+ LL+IN L-IN CP-B 24/X 1 24 V DC 12 L+ OUTL-OUT 13 2 L1 L2 L3 N 2CDC 252 003 F0014 9 24 V DC 24 V DC 7 7 10 A1 A2 Y1 Y2 Y3 Y0 10 L1 L2 L3 N A1 A2 Y1 Y2 Y3 Y0 L1 L2 L3 N CM-UFD ESC CM-UFD ESC U/T F U/T F OK OK 14 11 12 24 21 22 34 31 32 14 11 12 24 21 22 34 31 32 4 18 15 16 28 25 26 38 35 36 18 15 16 28 25 26 38 35 36 4 2 3 2 3 6 6 G 5 G 1. Main circuit breaker DG or DGL 2. DDI: Automatic circuit breaker or contactor equipped with low voltage coil and motor for automatic closure 3. Auxiliary contact of DDI, necessary for realizing the feedback function (compulsory for CM-UFD.M22) 4. DDI short-circuit protection 5. Generator and/or inverter 6. Generator (DDG) 7. Protection fuse for the measuring circuit of the CM-UFD.M22 (optional) 8. Shunt trip coil for feedback function (P>20 kW). This coil can control DG/DGL or DDG devices Example of single-phase application - CM-UFD.M31 L1 N Public grid where applicable, a transformer 5 9. Control supply voltage for CM-UFD.M22 (SPI) and tripping device (DDI)* 10. Device protection fuse for the CM-UFD.M22 11. Primary switch mode power supply unit CP-E (230 V AC / 24 V DC) for the buffer module CP-B* 12. Ultra-capacitor based buffer module CP-B (24 V DC in/out) 13. Wire protection fuse for the output of the buffer module CP-B * In accordance to CEI 0-21 regulation, in case of loss of control supply voltage it’s asked to guarantee, at least for 5 seconds, the functionality of the CM-UFD.M22, the operability of the DDI and when present the command coil for operating the redundancy device. This function has to be realized by external buffer or UPS devices. Example of three-phase application - CM-UFD.M31 L1 L2 L3 N Public grid where applicable, a transformer 6 A 10 A A1 A2 1115 10 A 10 A 2125 3135 6 A L1 L2 L3 N A1 A2 1115 2125 3135 L1 L2 L3 N 1216 1418 2226 2428 3236 3438 Y3 Y2 Y1 Y0 1216 K1 1418 2226 2428 3236 3438 Y2 Y1 Y0 K1 K2 Y3 K2 Control input 1, feedback loop for switching device 1 Switching device 1 of the section switch Switching device 2 of the section switch Inverter(s) Generator(s) Control input 1, feedback loop for switching device 1 Control input 2, feedback loop for switching device 2 Control input 3 (e.g. for remote trip) Switching device 1 of the section switch Switching device 2 of the section switch Inverter(s) Generator(s) 2CDC 252 007 F0213 Control input 3 (e.g. for remote trip) 2CDC 252 006 F0213 Control input 2, feedback loop for switching device 2 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/52 Grid feeding monitoring relays Voltage and frequency monitoring functions Applications, connection diagram Example of single-phase application - CM-UFD.M33 L1 N L1 L2 L3 N 8 7 8 7 6 A 10 A A1 A2 10 A 10 A 1115 3135 2125 6 A L1 L2 L3 N 10 A A1 10 A 10 A 1115 A2 2125 3135 L1 L2 L3 N 3 2 1 1216 1418 2226 3236 2428 3438 Y3 Y2 Y1 Y0 3 2 1 1216 1 K1 1418 2226 2428 3236 3438 Y3 Y2 Y0 1 K1 2 K2 Y1 4 4 5 K2 2 5 1 Control input 1, feedback loop for switching device 1 2 Control input 2, feedback loop for switching device 2 6 2CDC 252 005 F0014 4 Switching device 1 of the section switch 5 Switching device 2 of the section switch 6 Inverter(s) / generator(s) 7 Transformer (if applicable) 8 Public grid 1 Control input 1, feedback loop for switching device 1 2 Control input 2, feedback loop for switching device 2 3 Control input 3 (e.g. for remote trip) 4 Switching device 1 of the section switch 5 Switching device 2 of the section switch 6 Inverter(s) / generator(s) 7 Transformer (if applicable) 2CDC 252 006 F0014 3 Control input 3 (e.g. for remote trip) 8 Public grid Electrical connection - CM-UFD.Mxx A1 A2 Y1 Y2 Y3 Y0 L1 L2 L3 N 2CDC 253 007 F0014 2 Example of three-phase application - CM-UFD.M33 A1-A2 L1, L2, L3, N Y1-Y0 Y2-Y0 Y3-Y0 CM-UFD ESC Test U/T F 1115 -1216/1418 2125 -22 26/2428 3135 -3236/34 38 OK 14 11 12 24 21 22 34 31 32 18 15 16 28 25 26 38 35 36 2/53 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Control supply voltage U s Measuring inputs Control input 1: Feedback from switching device 1 Control input 2: Feedback from switching device 2 Control input 3: Remote trip, suppress Y1, suppress Y2, suppress Y1/Y2 or suppress vector shift detection Output relay 1: Relay for tripping switching device 1 of the section switch, closed-circuit principle Output relay 2: Relay for tripping switching device 2 of the section switch, closed-circuit principle Output relay 3: Closing command for circuit breaker motor, configuration possibilities: closed-circuit principle, open-circuit principle, disabled or synchronous with R1/R2 Grid feeding monitoring relays Voltage and frequency monitoring functions Ordering and selection Ordering details Rated control supply voltage = measuring voltage Type Order code 24-240 V AC/DC CM-UFD.M22 1SVR510730R0300 24-240 V AC/DC CM-UFD.M31 1SVR510730R0300 24-240 V AC/DC CM-UFD.M33 1SVR560730R3400 Price 1SVR560730R3400 1SVR560730R3401 1SVR560730R3402 CM-UFD.M31 CM-UFD.M33 Rated control supply voltage Us 24-240 V AC/DC Standard Order number 1 pce CM-UFD.M22 CM-UFD.Mxx Only reliable and continuous monitoring of a three-phase network guarantees the trouble-free and economic operation of machines and installations. Type 2CDC 251 005 S0013 Description J J J Weight (1 pce) kg (lb) 0.225 (0.496) 0.225 (0.496) 0.304 (0.670) J VDE AR-N 4105, BDEW J G59/3 J CEI 0-21 Rated frequency DC or 50 Hz DC or 50/60 Hz Suitable for monitoring J J J Single-phase mains J J J Three-phase mains J J J Over-/undervoltage J J J Over-/underfrequency J J J ROCOF (rate of change of frequency) J J J J J J Vector shift J J Thresholds adj adj adj Monitoring function 10 minutes average value 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/54 2 Grid feeding monitoring relays Voltage and frequency monitoring functions Technical data - CM-UFD.Mxx Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated 2 Type CM-UFD.M22 Input circuit - Supply circuit Rated control supply voltage U s 24-240 V AC/DC Rated control supply voltage U s tolerance -15…+10 % Rated frequency Frequency range AC Typical current / power consumption overvoltage 10-min average (>UAV) adjustable, 1.00-1.30 * U s in 0.01*U s steps overvoltage (>U1) adjustable, 1.00-1.20 * U s in 0.01*U s steps overvoltage (>U2) undervoltage ( F1) adjustable, 50.0-54.0 Hz in 0.1 Hz steps underfrequency ( F1) adjustable, 50.0-54.0 Hz in 0.1 Hz steps underfrequency ( UAV ) overvoltage (>U1, >U2) undervoltage ( F1, >F2) underfrequency ( 240 V Mounting Mounting position Minimum distance to other units Material of housing Degree of protection Electrical connection Stripping length Tightening torque Environmental data Ambient temperature ranges Climatic category Damp heat, cyclic Vibration, sinusoidal Shock, half-sine 1) 10 mm (0.39 in) at U n > 400 V UL 94 V-0 housing / terminal IP50 / IP20 Screw connection technology Wire size 45 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in) 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in) CM-IWN.xP: 0.217 kg (0.478 lb) CM-IWN.xS: 0.241 kg (0.531 lb) CM-IWN.xP: 0.246 kg (0.542 lb) CM-IWN.xS: 0.270 kg (0.595 lb) without any tool fine-strand with(out) wire end 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG) ferrule 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG) 2 x 0.5-2.5 mm 2 (2 x 20-14 AWG) 8 mm (0.32 in) 0.6-0.8 Nm (5.31-7.08 lb.in) operation / storage / transport IEC/EN 60721-3-3 IEC/EN 60068-2-30 IEC/EN 60255-21-1 IEC/EN 60255-21-2 Closed-circuit principle: Output relay(s) de-energize(s) if a fault is occuring Open-circuit principle: Output relay(s) energize(s) if a fault is occuring 2/69 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Easy Connect Technology (Push-in) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) -25...+60 °C/-40...+85 °C/-40...+85 °C 3K5 (no condensation, no ice formation) 6 x 24 h cycle, 55 °C, 95 % RH Class 2 Class 2 Insulation monitoring relays for unearthed supply systems Technical data CM-IWS.2 CM-IWS.1 CM-IWN.1, 4, 5, 6 Isolation data Rated impulse withstand voltage U imp between all isolated circuits (IEC/EN 60947-1, IEC/EN 60664-1, VDE 0110-1) supply / measuring circuit 6 kV supply / output circuit 6 kV measuring / output circuit 6 kV output 1 / output circuit 2 4 kV Pollution degree (IEC/EN 60664-1, VDE 0110-1) 3 Overvoltage category (IEC/EN 60664-1, VDE 0110-1) III Rated insulation voltage U i supply / measuring circuit 400 V 300 V 600 V (IEC/EN 60947-1, IEC/EN 60664-1, VDE 0110-1) supply / output circuit 300 V supply / measuring circuit 400 V 300 V 600 V output 1 / output circuit 2 300 V Basis isolation for rated control supply voltage supply / measuring circuit 400 V AC / 300 V DC 250 V AC / 300 V DC 400 V AC / 600 V DC (IEC/EN 60664-1, VDE 0110-1) supply / output circuit 250 V AC / 300 V DC measuring / output circuit 400 V AC / 300 V DC 250 V AC / 300 V DC 400 V AC / 600 V DC output 1 / output 2 250 V AC / 300 V DC Protective separation (IEC/EN 61140) supply / output circuit 250 V AC / 250 V DC supply / measuring circuit 250 V AC / 250 V DC measuring / output circuit 250 V AC / 250 V DC Test voltage between all isolated circuits, supply / output circuit 2.32 kV, 50 Hz, 2 s routine test (IEC/EN 60255-5, IEC/EN 61010-1) supply / measuring circuit 2.32 kV, 50 Hz, 2 s measuring / output circuit 2.2 kV, 50 Hz, 1 s 2.53 kV, 50 Hz, 1 s Standards Product standard IEC/EN 61557-1, IEC/EN 61557-8, IEC/EN 60255-1, EN 50178 Other standards EN 50178 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2011/65/EC Electromagnetic compability Interference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61326-2-4 electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz) electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz surge IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-earth conducted disturbances, induced by IEC/EN 61000-4-6 Level 3, 10 V radio-frequency fields voltage dips, short interruptions and IEC/EN 61000-4-11 Class 3 voltage variations harmonics and interharmonics IEC/EN 61000-4-13 Class 3 Interference emissions IEC/EN 61000-6-3, IEC/EN 61000-6-4 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/70 2 Insulation monitoring relays for unearthed supply systems Technical data CM-IVN Input circuit - Measuring circuit Function 2 VL+, VL-, Vw expansion of the nominal voltage range of the insulation monitoring relay CM-IWN to 690 V AC or 1000 V DC, max. length of connection cable 40 cm see CM-IWN 0-690 V AC / 0-1000 V DC 0-793.5 V AC / 0-1150 V DC (tolerance +15 %) DC or 15-400 Hz Measuring principle Nominal voltage U n of the distribution system to be monitored Voltage range of the distribution system to be monitored Rated frequency f N of the distribution system to be monitored Tolerance of the rated frequency f N System leakage capacitance C e Extraneous DC voltage U fg (when connected to an AC system) Tolerance of the adjusted threshold value / Relative percentage uncertainty A at -5...+ 45 °C, U n = 0-115 %, U s = 85-110 %, f N , f s , C e = 1 μF Internal impedance Z i Internal DC resistance R i Measuring voltage U m Tolerance of measuring voltage U m Measuring current I m 13.5-440 Hz max. identical to that of the insulation monitoring relay used max. 793.5 V DC at 1-15 kΩ R F ±1.5 kΩ at 15-200 kΩ R F ±8 % at 50 Hz 195 kΩ 200 kΩ 24 V +10 % 0.15 mA General data MTBF Duty time Dimensions (W x H x D) Weight gross weight net weight Mounting Mounting position Minimum distance to other units vertical horizontal Degree of protection Electrical connection Wire size fine-strand with(out) wire 2 x 0.75-2.5 mm² (2 x 18-14 AWG) end ferrule rigid 2 x 0.5-4 mm² (2 x 20-12 AWG) 7 mm (0.28 in) 0.6-0.8 Nm (5.31-7.08 lb.in) 40 cm Stripping length Tightening torque Max. length of connection cable to CM-IWN Environmental data Ambient temperature ranges operation Climatic category Damp heat, cyclic Vibration, sinusoidal Shock, half-sine Isolation data Rated impulse withstand voltage U imp between all isolated circuits (IEC/EN 60947-1, IEC/EN 60664-1,VDE 0110-1) Pollution degree (IEC/EN 60664-1, VDE 0110-1) Overvoltage category (IEC/EN 60664-1, VDE 0110-1) Rated insulation voltage U i (IEC/EN 60947-1, IEC/EN 60664-1,VDE 0110-1) Test voltage between all isolated circuits, routine test (IEC/EN 60255-5, IEC/EN 61010-1) Standards Product standard Other standards Low Voltage Directive EMC Directive RoHS Directive Electromagnetic compability Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations harmonics and interharmonics Interference emission high-frequency radiated high-frequency conducted on request 100 % 45 x 78 x 100 mm (1.78 x 3.07 x 3.94 in) 0.200 kg (0.441 lb) 0.169 kg (0.373 lb) DIN rail (IEC/EN 60715), snap-on mounting without any tool any not necessary 10 mm (0.39 in) at U n > 600 V IP50 / IP20 / storage / transport IEC/EN 60721-3-3 IEC/EN 60068-2-30 IEC/EN 60255-21-1 IEC/EN 60255-21-2 -25...+60 °C / -40...+85 °C / -40...+85 °C 3K5 (no condensation, no ice formation) 6 x 24 h cycle, 55 °C, 95 % RH Class 2 Class 2 input circuit / PE 8 kV 3 III input circuit / PE 1000 V input circuit / PE 3.3 kV, 50 Hz, 1 s IEC/EN 61557-1, IEC/EN 61557-8, IEC/EN 60255-1, EN 50178 EN 50178 2006/95/EC 2004/108/EC 2011/65/EC IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61326-2-4 IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz) IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-earth IEC/EN 61000-4-6 Level 3, 10 V IEC/EN 61000-4-11 Level 3 IEC/EN 61000-4-13 Level 3 IEC/EN 61000-6-3, IEC/EN 61000-6-4 IEC/CISPR 22, EN 50022 Class B IEC/CISPR 22, EN 50022 Class B 2/71 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Insulation monitoring relays for unearthed supply systems Notes 2 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/72 Motor load monitoring relays Product picture 2 2/73 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Motor load monitoring relays Table of contents Motor load monitoring relays Fields of application 2/75 Ordering details 2/76 Technical information 2/77 Technical data 2/78 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/74 2 Motor load monitoring relays Fields of application (e.g. pressure transducers, current measurement), cos ϕ monitoring is a more precise and economical alternative. The motor is used as a sensor for its own load status. Pump control Dry-running protection Detected fault - installation is switched off M 3~ L1 L2 L3 N 50-60 Hz ~ ~ 110-500 V, 15-400 Hz 50-60 Hz L1 L2 L3 N U1 U V W M 3~ U2 M 1~ 110-240 V 15-400 Hz DC K1 Starting time delay Detected fault - installation is switched off Wiring examples (for motor currents 20 A) K1 L1 L2 L3 1SVC 110 000 F 0473 1SVC 110 000 F 0472 Starting time delay AC 2/75 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 50-60 Hz U V W M 3~ K l L K1 U V W M 3~ L1 N K1 k 1SVC 110 000 F 0131 U V W 1SVC 110 000 F 0471 Filter pollution V-belt monitoring 50-60 Hz k K l L K1 U1 U2 M 1~ 1SVC 110 000 F 0132 K1 Response delay 1SVC 110 000 F 0132 L1 N Detected fault - installation is switched off Ventilator monitoring 1SVC 110 000 F 0133 50-60 Hz Starting time delay Detected fault - installation is switched off Response delay 1SVC 110 000 F 0131 L1 L2 L3 N Filter pollution 1SVC 110 000 F 0470 Starting time delay Wiring examples (for motor currents 20 A) 1SVC 110 000 F 0133 2 The motor load monitor relay monitors the load states of single-phase and three-phase asynchronous motors. The evaluation of the phase angle between current and voltage allows a very precise monitoring of the load states. Compared with other conventional measuring principles Main applications –– Pump monitoring –– Dry-running protection (underload) –– Closed valves (overload) –– Pipe break (overload) –– Heating, air-conditioning, ventilation –– Monitoring of filter pollution –– V-belt breakage (underload) –– Closed shutters/valves (overload) –– Air ventilating volume –– Agitating machines –– High consistency within the tank (overload) –– Pollution of the tank (overload) –– Transport/Conveyance –– Congested conveyor belts (overload) –– Jamming of belts (overload) –– Material accumulation in spiral conveyors (overload) –– Lifting platforms –– Machine installation –– Wear of tools, e.g. worn saw blades in circular saws, etc. (overload) –– Tool breakage (underload) –– V-belt drives (breakage underload) Motor load monitoring relays Ordering details Description 1SVR 450 335 F0100 The motor load monitor CM-LWN monitors the load of single-phase and three-phase asynchronous motors. The evaluation of the phase angle between current and voltage (cos j monitoring) allows a very precise monitoring of the load status. Ordering details Rated control supply voltage Current range Type = measuring voltage CM-LWN Order code Price Weight (1 pce) 1 pce kg (lb) 24-240 V AC/DC 1SVR450335R0000 0.30 (0.66) 110-130 V AC 1SVR450330R0000 0.30 (0.66) 220-240 V AC 1SVR450331R0000 0.30 (0.66) 380-440 V AC 0.5-5 A 1SVR450332R0000 0.30 (0.66) 480-500 V AC 1SVR450334R0000 0.30 (0.66) 1SVR450335R0100 0.30 (0.66) 1SVR450330R0100 0.30 (0.66) 1SVR450331R0100 0.30 (0.66) 380-440 V AC 1SVR450332R0100 0.30 (0.66) 480-500 V AC 1SVR450334R0100 0.30 (0.66) CM-LWN 24-240 V AC/DC 110-130 V AC 220-240 V AC 2-20 A Current transformers see „General technical data, Accessories, Current transformers“ on page 128. Characteristics – – Pump monitoring – – Under- and overload monitoring cos j in one unit – – Adjustable starting delay 0.3-30 s – – Direct measurement of currents up to 20 A – – Adjustable response time delay 0.2-2 s – – Single-phase or three-phase monitoring – – 2 x 1 c/o contact, closed-circuit principle – – 3 LEDs for status indication 1 Starting delay „Time S“ 2 Response delay „Time R“ 1 2 3 Threshold for load limit cos ϕmax 4 Threshold for load limit cos ϕmin 5 Reset button 6 Indication of operational states 3 4 U: green LED – control supply voltage cos ϕ max: red LED – cos ϕ max exceeded cos ϕ min: red LED – below cos ϕ min 7 Marker label 5 2CDC 253 010 F0013 7 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/76 2 Motor load monitoring relays Technical information 1SVC 110 000 F0130 Function diagram - CM-LWN A1-A2 Current in L1 con ϕmax hysteresis con ϕmin 15-18 15-16 25-28 25-26 Reset button Red LED - cos ϕmin Red LED - cos ϕmax TS TR TR TR TS Connection diagram CM-LWN 2CDC 252 105 F0004 2 The CM-LWN module monitors the load status of inductive loads. The primary application is the monitoring of single- or three-phase asynchronous motors (squirrel cage) under varying load conditions. The measuring principle is based on the evaluation of the phase shift (ϕ) between the voltage and the current in one phase. The phase difference is nearly inversely proportional to the load. Therefore, cos ϕ, measured relatively from 0 to 1, measures the relationship of effective power to apparent power. A value towards 0 indicates low load and a value towards 1 indicates high load. Threshold values can be set individually for cos ϕ max and cos ϕ min If the set threshold value is reached, a LED lights up and the relay is de-energized. If cos ϕ returns to the acceptable limits (taking into account the hysteresis), the relay is reset to its original state and the LED flashes permanently to indicate the occurrence of the trip event. This message can be deleted using the reset button or by switching off the supply. A time delay (Time S) of 0.3 to 30 s can be set for the starting phase of the motor. It is also possible to set a response delay time (Time R) of 0.2 to 2 s to suppress unwanted tripping due to unavoidable short load changes during normal operation. To guarantee correct operation of the response delay (Time R), the adjusted value for cos ϕ max has to be higher than the value for cos ϕ min plus the hysteresis. Consequently, the overload and underload indication must not be active at the same time. Due to the internal electrical isolation of the supply circuit and the measuring circuit, it is also possible to use the device in systems with different supply voltages. A1-A2 L1/K-L1/L L1/K-L2-L3 15-16/18 25-26/28 Rated control supply voltage Measuring current Measuring voltage Output contacts - underload (cos ϕ min) Output contacts - overload (cos ϕ max) closed-circuit principle 2/77 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Motor load monitoring relays Technical data Type Input circuit - Supply circuit Rated control supply voltage U s - power consumption Rated control supply voltage U s tolerance Rated frequency Duty time Measuring circuit Monitoring function A1-A2 A1-A2 A1-A2 A1-A2 A1-A2 AC versions AC/DC versions Voltage range Current range Permissible overload of current input Thresholds CM-LWN A1-A2 24-240 V AC/DC approx. 8.4 VA/W 110-130 V AC approx. 3.6 VA 220-240 V AC approx. 3.6 VA 380-440 V AC approx. 3.6 VA 480-500 V AC approx. 3.6 VA -15 %...+10 % 50-60 Hz 15-400 Hz or DC 100 % L1/L-L1/K-L2-L3 Motor load monitoring by cos ϕ L1/K-L2-L3 110-500 V AC single-phase or three-phase L1/L-L1/K 0.5-5 A version 2-20 A version 25 A for 3 s 100 A for 3 s cos ϕmin and cos ϕmax adjustable from 0 to 1 Hysteresis (related to phase angle ϕ in °) Frequency of measuring voltage Response time Timing circuits Start-up time (Time S) Response delay (Time R) Accuracy within the rated control supply voltage tolerance Accuracy within the temperature range Indication of operational states Control supply voltage below cos ϕmin cos ϕmax exceeded 4° 15-400 Hz 300 ms Output circuits Kind of output Operational principle Contact material Rated voltage (VDE 0110, IEC 664-1, IEC 947-1) Max. switching voltage Rated operational current I e (IEC/EN 60947-1) 15-16/18, 25-26/28 2 x 1 c/o contact closed-circuit principle 1) AgCdO 250 V 400 V AC, 300 V DC 4A 3A 4A 2A B 300 300 V AC 5A 3600/360 VA 30 x 10 6 switching cycles 0.1 x 10 6 switching cycles 10 A fast-acting / 10 A fast-acting AC rating (UL 508) indication of over- and undervoltage fault 0.3-30 s, adjustable 0.2-2 s, adjustable t m 0.5 % t m 0.06 % / °C U: green LED cos ϕmin: red LED cos ϕmax: red LED AC-12 (resistive) 230 V AC-15 (inductive) 230 V DC-12 (resistive) 24 V DC-13 (inductive) 24 V Utilization category (Control Circuit Rating Code) max. rated operational voltage max. continuous thermal current at B 300 max. making/breaking apparent power at B 300 Mechanical lifetime Electrical lifetime at AC-12, 230 V, 4 A Max. fuse rating to achieve short-circuit n/c / n/o contact protection General data Dimensions (W x H x D) Mounting position Degree of protection housing / terminals Ambient temperature range operation / storage Mounting Electrical connection Wire size fine-strand with wire end ferrule Standards Product standard Low Voltage Directive EMC Directive Electromagnetic compatibility electrostatic discharge IEC/EN 61000-4-2 radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 electrical fast transient / burst IEC/EN 61000-4-4 surge IEC/EN 61000-4-5 conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Operational reliability (IEC 68-2-6) Mechanical resistance (IEC 68-2-6) Environmental testing (IEC 68-2-30) Isolation data Rating (HD 625.1 S1, VDE 0110, IEC 664-1, IEC 60255-5) Rated insulation voltage between supply- , measuring- and output circuit Rated impulse withstand voltage between all isolated circuits Test voltage between all isolated circuits Pollution category Overvoltage category 1) 45 mm x 78 mm x 100 mm (1.77 inch x 3.07 inch x 3.94 inch) any IP50 / IP20 -25...+65 °C / -40...+85 °C DIN rail (IEC/EN 60715) 2 x 2.5 mm 2 (2 x 14 AWG) IEC 255-6, EN 60255-6 2006/95/EC 2004/108/EC, 91/263/EEC, 92/31/EEC, 93/68/EEC, 93/67/EEC EN 61000-6-2, EN 61000-6-4 Level 3 (6 kV / 8 kV) Level 3 (10 V/m) Level 3 (2 kV / 5 kHz) Level 4 (2 kV L-L) Level 3 (10 V) 5g 10 g 24 h cycle time, 55 °C, 93 % rel., 96 h 250 V, 400 V, 500 V depending on the version 4 kV / 1.2 - 50 µs 2,5 kV, 50 Hz, 1 min. 3 III Open-circuit principle: Output relay is energized if the measured value exceeds/drops below the adjusted threshold. Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/78 2 Motor control and protection Product group picture 2 2/79 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Motor control and protection Table of contents Motor control and protection Benefits and advantages 2/81 Technical data 2/82 2 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/80 Motor control and protection Benefits and advantages 2 UMC100.3 is a flexible, modular and expandable motor management system for constant-speed low-voltage range motors. It's most important tasks include motor protection, prevention of plant standstills and the reduction of down time. This is made possible by early information relating to possible motor problems which avoids unplanned plant standstills. Even if a motor trips, quick diagnosis of the cause of the fault serves to reduce downtime. UMC100.3 combines in a very compact unit: Motor protection – – Overload, underload – – Overvoltage, undervoltage – – Blocked rotor, low / high current – – Phase failure, imbalance, phase sequence – – Earth leakage – – Thermistor protection – – Limitation of starts per time – – One single version with integrated measuring system covers the rated motor current from 0.24 to 63 A Motor control – – Integrated and easy to parametrize motor starter functions like direct, reverse, star-delta,... – – Additionally free programmable logic for application specific control functions – – Expansion modules DX111, DX122 for more I/Os – – Expansion modules VI150, VI155 for 3-phase voltage measuring – – Analog and temperature module AI111 Motor diagnostics – – Quick and comprehensive access to all relevant data via fieldbus and/or operator panel – – Current, thermal load – – Phase voltages – – Power factor – – Energy Further information UMC Catalog UMC Brochure Communication –– Communication-independent basic device –– Freely selectable fieldbus protocol with FieldBusPlug –– Profibus DP –– DeviceNet –– Modbus RTU –– Ethernet Modbus TCP –– Profinet Typical application segments –– Oil & gas –– Cement –– Paper –– Mining –– Steel –– Chemical industry 2CDC 190 022 C0206 2CDC 135 011 B0203 2/81 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Motor control and protection Technical data Basic device UMC100.3 Main power Voltage max 1000 V AC Frequency 45…65 Hz Rated motor current 0.24…63 A, without accessories Higher currents with external transformer Tripping classes 5E, 10E, 20E, 30E, 40E in accordance with EN/IEC 60947-4-1 Short-circuit protection Separate fuse on network side Control unit Supply voltage 24 V DC, 110-240 V AC/DC Inputs 6 digital inputs 24 V DC 1 PTC input Outputs 3 digital relay outputs 1 digital transistor output Expansion modules The UMC100.3 can be expanded with maximum 4 expanstion modules: One digital expansion module DX111 or DX122, one module VI150 or VI155 and 2 analog modules AI111. Communication takes place via a simple two-wire line. The maximum distance allowed between the UMC100.3 and the expansion module is 3 m. Digital expansion modules DX111 / DX122 Expands the UMC100.3 to include additional digital inputs and outputs and an analog output Supply voltage 24 V DC Inputs DX111: 8 digital inputs 24 V DC DX122 8 digital inputs 110/230 V AC Outputs 4 digital relay outputs 1 analog output, 0/4…20 mA, / 0…10 V configurable Voltage modules VI150/VI155 Voltage modules for determining phase voltages, power factor (cos j), active power, apparent power, energy, harmonic content (THD) VI150 for use in grounded networks VI155 for use in grounded and ungrounded networks Supply voltage 24 V DC Voltage inputs L1, L2, L3 Rated voltage range 150 … 690 V AC Outputs 1 digital relay output Analog module AI111 Expand the UMC100.3 with analog and temperature inputs Supply voltage 24 V DC Inputs 0-10 V, 0/4-20 mA PT100, PT1000, 2- or 3-wire connection KTY83, KTY84, NTC 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/82 2 Motor control and protection Technical data Ethernet communication interfaces Mounted in the MCC cable chamber; connection of 1 to 4 motor controllers UMC100.3 via simple cables MTQ22 for Modbus TCP PNQ22 for Profinet IO 2 Fieldbus communication interfaces Can be mounted direct on the UMC100.3 or separate in the cable chamber of the MCC. Connection for standard fieldbus cables with 9-pole Sub-D (Profibus DP) or terminal blocks PDP32 for Profibus DP DNP31 for DeviceNet MRP31 for Modbus RTU CEM11 earth leakage sensors Summation current transformer for connecting to a digital input Mounting with bracket on DIN busbar or wall Models CEM11-FBP.20 80 – 1,700 mA 20 mm Ø CEM11-FBP.35 100 – 3,400 mA 35 mm Ø CEM11-FBP.60120 – 6,800 mA 60 mm Ø CEM11-FBP.120 300 – 13,600 mA 120 mm Ø Current transformer CT4L / CT5L Only required for rated motor currents >63 A Linear transformer, 3-phase with terminal block, designed for connecting leads Cu 2.5 mm 2 UMC100-PAN control panel Installation on the device or on the switching cabinet door Graphics-enabled and backlit display, 3 LEDs for status indication Freely configurable error messages USB port for PC connection Multilingual: German, English, French, Italian, Polish, Portuguese, Spanish, Russian 2/83 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Motor control and protection Notes 2 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/84 Thermistor motor protection relays Product group picture 2 2/85 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Thermistor motor protection relays Table of contents Thermistor motor protection relays Benefits and advantages, Applications 2/87 Operating controls 2/88 Selection table CM-MSS range 2/89 Ordering details 2/90 Ordering details - PTC temperature sensors C011 2/91 Technical data 2/92 Connection diagrams 2/95 Circuit diagram 2/96 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/86 2 Thermistor motor protection relays Benefits and advantages, Applications 2 The thermistor motor protection relays of the CM-MSx range protect motors with PTC sensors against high temperature. These sensors are incorporated in the motor windings thus measuring the motor heat directly. Direct temperature measuring Generally, motor damages caused by overload or overheating situations can be prevented in different ways. Compared to the indirect temperature measuring which monitors the motor current, the temperature inside the motor can be measured by direct temperature measuring. This enables direct control and evaluation of the following operating conditions like: –– Heavy duty starting –– Increased switching frequency –– Single phase operation –– Phase unbalance –– High ambient temperature –– Insufficient cooling –– Breaking operation Therefore the consequences from overheating like abrasion as well as electrical failures can be prevented. The direct measuring principle is carried out by a combination of the thermistor motor protection relay and 3 PTC sensors which are installed directly in the motor by the manufacturer. Those 3 PTC sensors are placed directly at the thermal hotspots, the motor windings. Monitoring the motor The thermistor motor protection relay measures the resistance of the PTC sensors which reflects the internal motor temperature permanently. If the temperature in the motor windings rises excessively and reaches the nominal response temperature (NRT), the thermistor motor protection relay detects this situation and the output relay switches off. By doing so the motor contactor gets triggered and switches off the motor. CM-MSS functionality video Characteristics CM-MSS1) –– Different types of contacts available –– 1 x 2 c/o (SPDT) contacts –– 2 x 1 c/o (SPDT) contact –– 1 n/o and 1 n/c contact –– 1 or 2 measuring circuits –– Different types of reset functions –– Automatic –– Manual –– Remote –– Rated control supply voltages –– 24 V AC/DC –– 24-240 V AC/DC –– 110-130 V AC, 220-240 V AC –– Approvals / Marks Features 1) – – Additional functions: –– Dynamic interrupted wire detection –– Short-circuit monitoring of the sensor circuit –– Non-volatile fault storage –– Single or sum evaluation – – Easy configuration via DIP switches – – LEDs to distinguish between different failure causes – – Screw connection technology or Easy Connect Technology available – – Test/Reset button available A C R K E I1) / a b Characteristics CM-MSE –– Auto reset –– Connection of several sensors (max. 6 sensors connected in series) –– Monitoring of bimetals –– 1 n/o contact –– Excellenct cost / performance ratio 2/87 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 1) Depending on device the characteristics vary, for detailled overview see „Selection table CM-MSx range“ on page 89. Thermistor motor protection relays Operating controls 1 Test / Reset button Reset - only possible if measured value < switch-on resistance 2 Indication of operational states with LEDs U: green LED - Status indication of control supply voltage V 1 Control supply voltage applied F: red LED - Fault message R: yellow LED - Status indication of the output relay 2 i Single evaluation 2 x 1 c/o (SPDT) contact j Accumulative evaluation 1 x 2 c/o (SPDT) contacts y Short-circuit detection de-activated x Short-circuit detection activated f Non-volatile fault storage activated e Non-volatile fault storage de-activated 2CDC 253 001 F0015 3 3 DIP switches 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/88 2 Order code 1SVR550805R9300 1SVR550800R9300 1SVR550801R9300 1SVR740720R1400 1SVR730720R1400 1SVR740700R0100 1SVR730700R0100 1SVR740700R2100 1SVR730700R2100 1SVR740722R1400 1SVR730722R1400 1SVR740700R0200 1SVR730700R0200 1SVR740700R2200 1SVR730700R2200 1SVR740712R1400 1SVR730712R1400 1SVR740712R0200 1SVR730712R0200 1SVR740712R2200 1SVR730712R2200 1SVR740712R1200 1SVR730712R1200 1SVR740712R1300 1SVR730712R1300 CM-MSE CM-MSE CM-MSS.11P CM-MSS.11S CM-MSS.12P CM-MSS.12S CM-MSS.13P CM-MSS.13S CM-MSS.21P CM-MSS.21S CM-MSS.22P CM-MSS.22S CM-MSS.23P CM-MSS.23S CM-MSS.31P CM-MSS.31S CM-MSS.32P CM-MSS.32S CM-MSS.33P CM-MSS.33S CM-MSS.41P CM-MSS.41S CM-MSS.51P CM-MSS.51S 2 Type CM-MSE Thermistor motor protection relays Selection table CM-MSx range 1 1 n 1 n 1 1 1 1 1 n 1 n 1 1 1 1 1 n 1 n 1 n 1 n 1 n 1 n 1 n 1 n 1 n 2 n 2 Characteristics ATEX approval Number of sensor circuits 1 Single or sum evaluation Number of LEDs 3 3 2 2 2 2 3 3 2 2 2 2 3 3 3 3 3 3 3 3 n 3 n 3 n n n n n n n n n n n n n n n n Contacts 1 c/o (SPDT) contact 2 c/o (SPDT) contacts 1 n/o n n n 1 n/c and 1 n/o n n n n n n 2 x 1 c/o or 1 x 2 c/o contacts, configurable Reset Manual n n n n n n n n n n n n n n Remote n n n n n n n n n n n n n n Auto n n n n n n n n n n n n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 2) n 2) Test button n n n n n n n n n n n n n n n n n n n n n n n n n n Functions Short-circuit detection n n n n n n n n n n n n Short-circuit detection, configurable Dynamic interrupted wire detection n n n n n n Non-volatile fault storage n n n n n n Non-volatile fault storage, configurable Rated control supply voltage US 24 V AC 110-130 V AC 220-240 V AC 24-240 V AC/DC n n n n n 24 V AC/DC n n n n 110-130 V AC, 220-240 V AC n n n n n n n n n n n n Connection type Push-in terminals Double-chamber cage connection terminals 1) 2) n n n n n For automatic reset, connect terminals S1 to T2. For automatic reset, connect terminals S1 to 1T2/2T2. 2/89 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 n n n n n n n n n n n n n n n n n Thermistor motor protection relays Ordering details Description The thermistor motor protection relays CM-MSx are used to control motors equipped with PTC temperature sensors. The PTC temperature sensors are incorporated in the motor windings to measure the motor heating. This enables direct control and evaluation of various operating conditions. Depending on the products also ATEX approvals for use in hazardous areas are availabe. ABB also offers PTC temperature sensors C011 (according to DIN 44081) which are suitable for embedding in motor windings. Ordering details CM-MSx 2CDC 251 014 V0014 Rated control Output supply voltage CM-MSS.51S Function 24 V AC 110-130 V AC 1 n/o Autoreset 220-240 V AC 24-240 V AC/DC 1 n/c, 1 n/o Autoreset, dynamic interrupted wire detection, non-volatile fault storage, ATEX approval 24 V AC/DC 1 c/o (SPDT) Autoreset 110-130 V AC, 220-240 V AC 1 c/o (SPDT) Autoreset 24-240 V AC/DC 1 n/c, 1 n/o Autoreset, dynamic interrupted wire detection, non-volatile fault storage, short-circuit detection, ATEX approval 24 V AC/DC 2 c/o (SPDT) Auto, manual or remote reset 110-130 V AC, 220-240 V AC 2 c/o (SPDT) Auto, manual or remote reset 24-240 V AC/DC 1 n/c, 1 n/o Auto, manual or remote reset, dynamic interrupted wire detection, non-volatile fault storage, short-circuit detection, ATEX approval 24 V AC/DC 2 c/o (SPDT) 110-130 V AC, 220-240 V AC 2 c/o (SPDT) Auto, manual or remote reset, dynamic interrupted wire detection, short-circuit detection, ATEX approval 2 c/o (SPDT) Auto, manual or remote reset, dynamic interrupted wire detection, non-volatile fault storage, short-circuit detection, ATEX approval 2x1 c/o or, 1x2 c/o Auto, manual or remote reset, dynamic interrupted wire detection, non-volatile fault storage, short-circuit detection, accumulative evaluation, ATEX approval 24-240 V AC/DC Type Order code Price Weight (1 pce) 1 pce kg (lb) CM-MSE 1SVR550805R9300 0.11 (0.24) CM-MSE 1SVR550800R9300 0.11 (0.24) CM-MSE 1SVR550801R9300 CM-MSS.11P 1SVR740720R1400 CM-MSS.11S 1SVR730720R1400 CM-MSS.12P 1SVR740700R0100 CM-MSS.12S 1SVR730700R0100 CM-MSS.13P 1SVR740700R2100 CM-MSS.13S 1SVR730700R2100 CM-MSS.21P 1SVR740722R1400 0.11 (0.24) 0.119 (0.263) 0.127 (0.280) 0.105 (0.231) 0.113 (0.249) 0.147 (0.324) 0.155 (0.342) CM-MSS.21S 1SVR730722R1400 0.126 (0.278) CM-MSS.22P 1SVR740700R0200 CM-MSS.22S 1SVR730700R0200 CM-MSS.23P 1SVR740700R2200 CM-MSS.23S 1SVR730700R2200 CM-MSS.31P 1SVR740712R1400 0.121 (0.267) 0.132 (0.291) 0.163 (0.359) 0.174 (0.384) CM-MSS.31S 1SVR730712R1400 0.128 (0.282) CM-MSS.32P 1SVR740712R0200 CM-MSS.32S 1SVR730712R0200 CM-MSS.33P 1SVR740712R2200 CM-MSS.33S 1SVR730712R2200 CM-MSS.41P 1SVR740712R1200 0.120 (0.265) 0.130 (0.287) 0.162 (0.357) 0.172 (0.379) CM-MSS.41S 1SVR730712R1200 CM-MSS.51P 1SVR740712R1300 CM-MSS.51S 1SVR730712R1300 0.118 (0.260) 0.120 (0.265) 0.130 (0.287) 0.141 (0.311) 0.135 (0.298) 0.145 (0.320) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/90 2 Thermistor motor protection relays Ordering details - PTC temperature sensors C011 1SVC 110 000 F0531 2 Temperature sensor characteristics RPTC [] 104 103 101 1) TNF - 20 K TNF - 5 K TNF TNF + 5 K TNF + 15 K -20 °C TPTC [°C] 2CDC 252 068 F0208 102 Temperature sensor C011, standard version acc. to DIN 44081 2) Triple temperature sensor C011-3 Description The PTC temperature sensors (temperature-dependent with positive temperature coefficient) are selected by the manufacturer of the motor depending on: – – the motor insulation class according to IEC/EN 60034-11, – – the special characteristics of the motor, such as the conductor cross-section of the windings, the permissible overload factor etc. – – special conditions prescribed by the user, such as the permissible ambient temperature, risks resulting from locked rotor, extent of permitted overload etc. One temperature sensor must be embedded in each phase winding. For instance, in case of three-phase squirrel cage motors, three sensors are embedded in the stator windings. For pole-changing motors with one winding (Dahlander connection), 3 sensors are also sufficient. Pole-changing motors with two windings, however, require The sensors are suitable for embedding in motor windings with rated operating voltages of up to 600 V AC. Conductor length: 500 mm per sensor. A 14 V varistor can be connected in parallel to protect the sensors from overvoltage. Due to their characteristics, the thermistor motor protection relays can also be used with PTC temperature sensors of other manufacturers which comply with DIN 44 081 and DIN 44 082 6 sensors. If an additional warning is required before the motor is switched off, separate sensors for a correspond ingly lower temperature must be embedded in the winding. They have to be connected to a second control unit. Ordering details Rated response temperature TNF 70 °C 80 °C 90 °C 100 °C 110 °C 120 °C 130 °C 140 °C 150 °C 160 °C 170 °C 150 °C Color coding Type Order code white-brown white-white green-green red-red brown-brown gray-gray blue-blue white-blue black-black blue-red white-green black-black C011-701) C011-801) C011-901) C011-1001) C011-1101) C011-1201) C011-1301) C011-1401) C011-1501) C011-1601) C011-1701) C011-3-1502) Price Weight (1 pce) kg (lb) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.05 (0.11) 1 pce GHC0110003R0001 GHC0110003R0002 GHC0110003R0003 GHC0110003R0004 GHC0110003R0005 GHC0110003R0006 GHC0110003R0007 GHC0110003R0011 GHC0110003R0008 GHC0110003R0009 GHC0110003R0010 GHC0110033R0008 Technical data Characteristic data Cold-state resistance Warm-state resistance ± 5 up to 6 K of rated response temperature T NF Thermal time constant, sensor open 1) Permitted ambient temperature Sensor type C011 50 -100 q at 25 °C 10 000 q <5s +180 °C Rated response tempera- PTC resistance R ture w tolerance TNF w iTNF from -20 °C to TNF - 20 K 70 w5 °C 80 w5 °C 90 w5 °C 100 w5 °C 110 w5 °C 120 w5 °C 130 w5 °C 140 w5 °C 150 w5 °C 160 w5 °C 170 w7 °C 1) 2) m 100 q Not embedded in windings. For triple temperature sensor take values x 3. 2/91 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 PTC resistance R2) at PTC temperatures of: TNF + 15 K TNF - iTNF TNF + iTNF (UPTC m 2.5 V) (UPTC m 7.5 V) (UPTC m 2.5 V) m 570 q M 570 q - m 550 q M 1330 q M 4000 q m 570 q M 570 q - Thermistor motor protection relays Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated Supply circuit - Input circuit CM-MSS.x1 Rated control supply voltage U s CM-MSS.x2 CM-MSS.x3 A1-A2 24-240 V AC/DC 24 V AC/DC 220-240 V AC A2-A3 - - 110-130 V AC Rated control supply voltage U s tolerance -15...+10 % Rated frequency 15-400 Hz 50-60 Hz Electrical insulation between supply circuit and measuring circuit yes no Power failure buffering time 20 ms yes Supply circuit - Measuring circuit / Sensor circuit Number of circuits 1 (CM-MSS.51: 2) Sensor type PTC type A (DIN/EN 44081, DIN/EN 44082) Max. total resistance of sensors connected in series, cold state < 750 Overtemperature monitoring W switch-off resistance (relay de-energizes) 2.83 kW w 1% (CM-MSS.12 /.13 /.22 /.23: 2.7 kW w 5%) switch-on resistance (relay energizes) 1.1 kW w 1% (CM-MSS.12 /.13 /.22 /.23: 1.2 kW w 5%) Maximum voltage in sensor circuit 1.33 kW 2.5 V 4 kW 3.7 V y kW 5.5 V 3.7 mA Maximum current in sensor circuit Maximum sensor cable length 2 x 100 m at 0.75 mm 2, 2 x 400 m at 2.5 mm 2 Accuracy within the rated control supply voltage tolerance 0.50 % (CM-MSS.12 /.13 /.22 /.23: 5 %) Accuracy within the temperature range 0.01 %/K (CM-MSS.12 /.13 /.22 /.23: 0.5 %/K) Repeat accuracy (constant parameters) on request Reaction time of the safety function < 100 ms Hardware fault tolerance (HFT) 0 Control circuit Control function see „Selection table CM-MSx range“ on page 89 Maximum no-load voltage 5.5 V Max. current 0.6 mA (CM-MSS.12 /.13 /.22 /.23: 1.2 mA) Maximum cable length 2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm² Indication of operational states Control supply voltage U LED green Relay status R LED yellow Fault message F LED red Output circuit Kind of output see „Selection table CM-MSx range“ on page 89 Operating principle closed-circuit principle Contact material AgNi alloy, Cd free Rated operational voltage U e (IEC/EN 60947-1) 250 V AC Minimum switching voltage / Minimum switching current 24 V / 10 mA Maximum switching voltage / Maximum switching current see data sheet Rated operating current I e (IEC/EN 60947-5-1) AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A DC-12 (resistive) at 24 V 4 A DC-13 (inductive) at 24 V 2 A AC Rating (UL 508) utilization category (Control Circuit Rating Code) B 300 maximum rated operational voltage 250 V AC maximum continuous thermal current at B 300 4 A maximum making/breaking apparent power at B 300 3600/360 VA Mechanical lifetime Electrical lifetime Maximum fuse rating to achieve short-circuit protection 30 x 10 6 switching cycles at AC12, 230 V AC, 4 A 0.1 x 10 6 switching cycles n/c contact 10 A fast-acting (CM-MSS.12, CM-MSS.13, CM-MSS.51: 6 A) n/o contact 10 A fast-acting 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/92 2 Thermistor motor protection relays Technical data - CM-MSS General data MTBF on request Duty time 2 100 % Dimensions (W x H x D) product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in) packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in) Weight see „Ordering details“ on page 90 Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units vertical 10 mm (0.394 in) if switching current > 2 A horizontal 10 mm (0.394 in) if switching current > 2 A Material of housing UL 94 V-0 Degree of protection housing IP50 terminals IP20 Electrical connection Screw connection technology Wire size Easy Connect Technology (push-in) fine‑strand with(out) wire end 1 x 0.5-2.5 mm (1 x 20-14 AWG) ferrule 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG) 2 x 0.5-2.5 mm2 (2 x 20-14 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG) 2 Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) - Wire end ferrule according to DIN 46228-1-A, DIN 46228-4-E - Environmental data Ambient temperature ranges operation -25 °C...+60 °C storage -40 °C...+85 °C Damp heat, cyclic (IEC/EN 60068-2-30) 6 x 24 h cycle, 55 °C, 95 % RH Climatic category (IEC/EN 60721-3-3) 3K5 (no condensation, no ice formation) Vibration, sinusoidal (IEC/EN 60255-21-1) Class 2 Shock (IEC/EN 60255-21-2) Class 2 Isolation data Rated insulation voltage U i (IEC/EN 60947-1, IEC/EN 60664-1) Supply circuit / Measuring circuit1) 300 V AC (CM-MSS.x2: n/a) Supply circuit / Output circuits 300 V AC Measuring circuit1) / Output circuits 300 V AC Output circuit 1 / Output circuit 2 300 V AC Rated impulse withstand voltage U imp (IEC/EN 60947-1, IEC/EN 60664-1) Basic insulation (IEC/EN 60664-1) Supply circuit / Measuring circuit1) 4 kV / 6 kV (CM-MSS.x2: n/a) Supply circuit / Output circuits 4 kV / 6 kV Measuring circuit1) / Output circuits 4 kV / 6 kV Output circuit 1 / Output circuit 2 4 kV Supply circuit / Measuring circuit1) 600 V AC (CM-MSS.x2: n/a) Supply circuit / Output circuits 600 V AC Measuring circuit1) / Output circuits 600 V AC Output circuit 1 / Output circuit 2 300 V AC Test voltage, routine test (IEC/EN 60255-27, IEC/EN 61010-1) Test voltage, type test (IEC/EN 60255-27) Supply circuit / Measuring circuit1) 2.5 kV, 50 Hz, 1 min. (CM-MSS.x2: n/a) Supply circuit / Output circuits 2.5 kV, 50 Hz, 1 min. Measuring circuit1) / Output circuits 2.5 kV, 50 Hz, 1 min. Supply circuit / Measuring circuit1) 6 kV / 1.2 - 50 μs (CM-MSS.x2: n/a) Supply circuit / Output circuits 6 kV / 1.2 - 50 μs Measuring circuit1) / Output circuits 6 kV / 1.2 - 50 μs Output circuit 1 / Output circuit 2 6 kV / 1.2 - 50 μs Protective separation (IEC/EN 61140, IEC/EN 50178) Supply circuit / Measuring circuit1) yes, up to 300 V Supply circuit / Output circuits yes (CM-MSS.x2: n/a) Measuring circuit1) / Output circuits yes Output circuit 1 / Output circuit 2 no Pollution degree (IEC/EN 60664-1) 3 Overvoltage category (IEC/EN 60664-1) III 1) Potential of measuring circuit = Potential of control circuit 2/93 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Thermistor motor protection relays Technical data - CM-MSS Standards Product standard IEC/EN 60255-1; IEC/EN 60947-8 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC ATEX directive 94/9/EC (only ATEX variants „Selection table CM-MSx range“ on page 89) RoHS directive 2011/65/EC Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV contact discharge, 8 kV air discharge radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz), 3 V/m (2 GHz), 1 V/m (2.7 GHz) electrical fast transient / burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz surge IEC/EN 61000-4-5 Level 3, Installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-N conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3, 0.15-80 MHz, 10 V, 80 % AM (1kHz) voltage dips, short interruptions and voltage variations IEC/EN 61000-4-11 Class 3 harmonics and interharmonics IEC/EN 61000-4-13 Class 3 Additional interference immunity according to product standard EN 60255-1 (reference on EN 60255-26_2011) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 10 V/m (80 MHz - 3 GHz) conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 10 V at stated frequencies damped oscillatory waves Interference emissions IEC/EN 61000-4-18 Signal lines, symmetric coupling: 1 kV peak voltage Power supply, asymmetric coupling: 2.5 kV peak voltage IEC/EN 61000-6-3, IEC/EN 61000-6-4 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B high-frequency radiated Germanischer Lloyd increased requirements in the emergency call frequency band 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/94 2 Thermistor motor protection relays Technical data - CM-MSE Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated 2 Supply circuit - Input circuit Rated control supply voltage U s power consumption CM-MSE 1SVR550805R9300 24 V AC approx. 1.5 A 1SVR550800R9300 110-130 V AC approx. 1.5 A 1SVR550801R9300 220-240 V AC approx. 1.5 A Rated control supply voltage U s tolerance -15...+10 % Rated frequency Measuring circuit Monitoring function Number of sensor circuits Sensor circuit Temperature threshold (relay de-energizes) Temperature hysteresis (relay energizes) Short-circuit threshold (relay de-energizes) Short-circuit hysteresis (relay energizes) Maximum total resistance of sensors connected in series (cold state) Maximum sensor cable length for short-circuit detection Response time Output circuit Kind of output 50-60 Hz T1-T2 temperature monitoring by means of PTC sensors 1 2.7-3.7 kW 1.7-2.3 kW <18 W >45 W 1.5 kW 2 x 100 m at 0.75 mm 2, 2 x 400 m at 2.5 mm 2 <100 ms 13-14 1 n/o contact Operational principle Contact material Rated voltage Maximum switching voltage Rated operating current I e (IEC/EN 60947-5-1) closed-circuit principle (output relay de-energizes if the measured value exceeds/drops below the adjusted threshold) AgCdO VDE 0110, IEC 664-1, IEC 60947-1 250 V 250 V AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A DC-12 (resistive) at 24 V 4 A DC-13 (inductive) at 24 V 2 A AC Rating (UL 508) utilization category (Control Circuit Rating Code) B 300 maximum rated operational voltage 300 V AC maximum continuous thermal current at B 300 5 A maximum making/breaking apparent power at B 300 3600/360 VA Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime at AC12, 230 V AC, 4 A 0.1 x 10 6 switching cycles Maximum fuse rating to achieve short-circuit n/c contact 10 A fast-acting protection n/o contact 10 A fast-acting General data Dimensions (W x H x D) 22.5 x 78 x 78.5 mm (0.89 x 3.07 x 3.09 in) Duty time 100 % Weight approx. 0.11 kg (0.24 lb) Mounting position any Degree of protection housing / terminals IP50 / IP20 Ambient temperature range operation -20...+60 °C storage -40...+85 °C Mounting DIN rail (IEC/EN 60715) Electrical connection Wire size fine strand with wire end ferrule 2 x 1.5 mm 2 (2 x 16 AWG) fine strand without wire end ferrule 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) rigid 2 x 1-1.5 mm 2 (2 x 18-16 AWG) Stripping length 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) Standards Product standard IEC 255-6, EN 60255-6 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC, 91/263/EEC, 92/31/EEC, 93/68/EEC, 93/67/EEC Electromagnetic compatibility electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m) electrical fast transient /burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz) surge IEC/EN 61000-4-5 Level 3/4 (1/2 kV) conducted disturbances, induced by radioIEC/EN 61000-4-6 Level 3 (10 V) frequency fields Operational reliability (IEC 68-2-6) 6g Resistance to vibration (IEC 68-2-6) 10 g Environmental testing (IEC 68-2-30) 24 h cycle time, 55 °C, 93 % rel., 96 h Electromagnetic compatibility Rated voltage between supply, measuring and output circuit 250 V Rated impulse withstand voltage between all isolated circuits 4 kV / 1.2 - 50 μs Test voltage between all isolated circuits 2.5 kV, 50 Hz, 1 min. Pollution degree 3 Overvoltage category III 2/95 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Thermistor motor protection relays Notes 2 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/96 Thermistor motor protection relays Connection diagrams 14 22 T1 ϑ A1 A3 T1 11 A1 A2 13 14 21 22 A2 T2 A2 14 12 14 12 A2 Control supply voltage A1 – A2 Control supply voltage 13 – 14 n/o contact 11 – 12/14 c/o contact 21 – 22 n/c contact T1 – T2 Measuring circuit T1 – T2 Measuring circuit T1 A1 21 T1 11 A1 A3 ϑ T2 S1 A2 24 14 A1 – A2 11 – 12/14 21 – 22/24 S1 – T2 (jumpered) T1 – T2 12 14 22 12 22 24 S1 A2 11 T2 T1 A1 A3 21 2CDC 252 019 F0014 S1 11 T2 CM-MSS.23, CM-MSS.33 T1 11 11 24 14 Control supply voltage 24 V AC/DC 1st c/o (SPDT) contact 2nd c/o (SPDT) contact Automatic reset A1 – A2 Measuring circuit 21 – 22/24 A2 – A3 11 – 12/14 S1 – T2 (jumpered) T1 – T2 12 14 22 12 A2 12 11 – 12/14 c/o contact T1 – T2 Measuring circuit CM-MSS.51 1T1 Control supply voltage 220-240 V AC Control supply voltage 110-130 V AC 1st c/o (SPDT) contact 2nd c/o (SPDT) contact Automatic reset Measuring circuit Control supply voltage 220-240 V AC Control supply voltage 110-130 V AC 21 S1 A2 A2 A2 – A3 A1 1T1 22 24 12 14 A1 – A2 S1 A2 S1 14 21 T1 ϑ T2 T2 2CDC 252 021 F0014 A1 A1 S1 T1 ϑ A1 – A2 CM-MSS.22, CM-MSS.32, CM-MSS.41 11 T2 T1 A1 A3 ϑ 2CDC 252 018 F0014 T2 11 T2 11 ϑ 1T2/2T2 2T1 S1 A2 12 24 14 A1 14 A2 13 21 T1 22 ϑ T2 14 21 22 A2 A1 – A2 Control supply voltage 13 – 14 n/o contact 21 – 22 n/c contact S1 – T2 (jumpered) Automatic reset T1 – T2 Measuring circuit CM-MSE 11 1T2/2T2 A1 13 T2 2CDC 252 047 F0014 A1 A1 CM-MSS.31 14 A1 A1 T1 21 T1 T2 A1 13 A2 14 ϑ ϑ 1T2/2T2 22 12 21 2T1 A2 22 S1 A2 24 T2 13 14 A2 1SVC 110 000 F0140 T1 21 T1 2CDC 252 022 F0014 2 13 T2 CM-MSS.13 2CDC 252 020 F0014 A1 CM-MSS.12 2CDC 252 017 F0014 CM-MSS.11, CM-MSS.21 A1 – A2 Control supply voltage 220-240 V AC A1 – A2 Control supply voltage 24 V AC T1-T2 Sensor circuit 11 – 12/14 1st c/o (SPDT) contact 13-14 21 – 22/24 2nd c/o (SPDT) contact Output contact Closed circuit principle S1 – 1T2/2T2 (jumpered) Automatic reset 1T1 – 1T2/2T2 Measuring circuit 1 2T1 – 1T2/2T2 Measuring circuit 2 2/97 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Thermistor motor protection relays Circuit diagram CM-MSS.11, CM-MSS.21 CM-MSS.12 V+ V+ A1 CM-MSS.13 V+ A1 14 A1 or A3 22 11 11 2 T1 T1 M 3~ M 3~ T2 t T2 A2 V- CM-MSS.22 t 14 12 A2 V- 2CDC 253 024 F0014 13 2CDC 253 023 F0014 t 21 CM-MSS.23 V+ 12 A2 V- CM-MSS.31 V+ V+ A1 14 A1 or A3 11 21 A1 11 T1 T1 T1 T2 T2 T2 t 22 14 Reset 12 A2 V- 24 22 14 Reset S1 12 A2 V- 2CDC 253 027 F0014 24 2CDC 253 026 F0014 t S1 µC M 3~ M 3~ t 21 13 Test / Reset S1 CM-MSS.32, CM-MSS.41 CM-MSS.33 CM-MSS.51 V+ V+ A1 or A3 11 21 A2 V- V+ A1 14 22 21 M 3~ 2CDC 253 025 F0014 T2 A1 11 2CDC 253 028 F0014 µC M 3~ T1 11 21 21 1T1 M 3~ T1 T1 µC 1T2/ 2T2 µC 24 22 Test / Reset 14 12 A2 V- t 24 22 Test / Reset 14 S1 V- 12 A2 M 3~ 24 22 2T1 t 14 12 Test / Reset S1 2CDC 253 016 F0014 T2 2CDC 253 015 F0014 T2 t S1 t µC M 3~ 2CDC 253 029 F0014 M 3~ A2 V- 1SVC 110 000 F0141 CM-MSE 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/98 Temperature monitoring relays Product group picture 2 2/99 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Temperature monitoring relays Table of contents Temperature monitoring relays Benefits and advantages, Applications Operating controls 2/99 2/100 Selection 2/101 Ordering details 2/102 Function diagrams 2/103 Overview, Functional description and diagrams 2/104 Connection diagrams, Resistance thermometer sensors 2/105 Technical data - CM-TCS.xx 2/106 Technical data - C51x 2/108 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/100 2 Temperature monitoring relays Benefits and advantages, Applications 2 Overview The temperature monitoring relays can be used for temperature measurement in solid, liquid and gaseous media. The temperature is acquired by the sensor in the medium, evaluated by the device and monitored to determine whether it is within an operating range (range monitoring function) or has exceeded or fallen below a threshold. Functional description The temperature monitoring relays CM-TCS monitor overtemperature, undertemperature, or temperatures between two threshold values (window monitoring) with PT100 sensor. As soon as the temperature falls below or exceeds the threshold value the output relays change their positions according to the configured functionality and the front-face LEDs display the current status. Regardless of the selected configuration, the device is monitoring its measuring circuit for interrupted wires or short‑circuits. Characteristics CM-TCS –– Adjustable sensor type: PT100 –– Functionality like overtemperature monitoring, undertemperature monitoring, temperature window monitoring configurable –– All configurations and adjustments by front-face operating elements –– Precise adjustment with direct reading scales –– One or two threshold values –– Hysteresis 2...20 % adjustable –– Operating temperature range -40...+60 °C –– 1 x 2 c/o or 2 x 1 c/o configurable –– Open- or closed-circuit principle configurable –– Short-circuit monitoring and interrupted wire detection –– 22.5 mm (0.89 in) width –– LEDs for status indication Characteristics C512 + C513 – – Adjustable sensor types: PT100, PT1000, KTY83, KTY84, NTC-B57227-K333-A1 – – Measuring principle for 2-wire and 3-wire sensors – – Temperature monitor for 1-3 sensor circuits – – Adjustable over-, undertemperature monitoring or range monitoring function – – 2 thresholds – – Hysteresis for both thresholds (1-99 Kelvin) – – Adjustable time delay from 0-999 s affects to both thresholds – – Storage function selectable via external signal (Y1-Y2) – – Non volatile storage of parameter settings – – 1 n/o (for wire-break and short-circuit detection) and 2 c/o – – Multifunctional digital display – – 3 LEDs for status indication – – Open- or closed-circuit principle selectable – – 45 mm wide housing with 24 terminals C512 – – Temperature monitor for 1 sensor circuit C513 – – Temperature monitor for 1-3 sensor circuits – – In the 3-sensor version the status of the single sensors is displayed if the temperature exceeds or falls below the threshold. This way it can be easily determined which one of the connected sensors has exceeded or dropped below either one or both threshold values. 2/101 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Temperature monitoring relays Operating controls 1 Adjustment of the hysteresis for threshold value t1 2 Adjustment of the threshold value t1 3 Indication of operational states 1 U: green LED – status indication of control supply voltage t: red LED – fault message, state of measuring input R: yellow LED – status indication of the output relays 4 Adjustment of the hysteresis for threshold value t2 2 5 Adjustment of the threshold value t2 6 DIP switch functions / marker label (on page 2/104) 3 4 Overtemperature monitoring Undertemperature monitoring Temperature window monitoring activated Temperature window monitoring de-activated Closed-circuit principle Open-circuit principle 2 x 1 c/o (SPDT) contact 1 x 2 c/o (SPDT) contacts 2CDC 253 019 F0013 5 p q r s g h i j 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/102 2 1SVR 730 740 R0300 1SVR 740 740 R0300 1SAR 700 100 R0005 1SAR 700 110 R0010 1SAR 700 110 R0010 CM-TCS.13S CM-TCS.13P C512-24 C512-W C513-W 1SVR 730 740 R0200 CM-TCS.12S 1SVR 740 740 R9300 1SVR 740 740 R9200 CM-TCS.22P CM-TCS.23P 1SVR 730 740 R9200 CM-TCS.22S 1SVR 730 740 R9300 1SVR 740 740 R0100 CM-TCS.11P 1SVR 740 740 R0200 1SVR 730 740 R0100 CM-TCS.23S 1SVR 740 740 R9100 J CM-TCS.11S J CM-TCS.21P J 1SVR 730 740 R9100 J CM-TCS.21S 24 V AC/DC Order number Rated control supply voltage Us Type 2 CM-TCS.12P Temperature monitoring relays Selection J J J J J J 24-240 V AC/DC J J J J J J J J J J Technology analogue J J J J J J J J J J digital Sensor circuits (2 or 3 wire) number of temperature sensors number of thresholds 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 J J J J J J J J J J J J J J J J J J J J J Sensor type PT100 PT100, KTY83, KTY84, NTC, PT1000 Measuring temperature range -50...+50 °C J J J J J 0...+100 °C J J J J 0...+200 °C J J J -50...+500 °C Monitoring function overtemperature J J J J J J J J J J J J J J J undertemperature J J J J J J J J J J J J J J J window temperature Operating principle open or closed principle Output contacts n/o J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J 1 1 1 c/o 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2/103 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Temperature monitoring relays Ordering details Description Acquisition, messaging and regulation of temperatures of solid, liquid and gaseous media in processes and machines via PT100, PT1000, KTY83, KTY84 or NTC sensors. ABB offers different temperature monitoring relays to meet the needs of your application: Ordering details - Temperature monitoring relays PT100 sensors, 2 or 3 wire connection, 2 thresholds adjustable Rated control supply voltage Measuring range 2CDC 251 031 V0012 -50...+50 °C 24-240 V AC/DC 0...+100 °C 0...+200 °C CM-TCS -50...+50 °C 24 V AC/DC 0...+100 °C 0...+200 °C Type Order code Price Weight (1 pce) 1 pce kg (lb) CM-TCS.11S 1SVR730740R0100 0.151 (0.333) CM-TCS.11P 1SVR740740R0100 0.140 (0.309) CM-TCS.12S 1SVR730740R0200 0.151 (0.333) CM-TCS.12P 1SVR740740R0200 0.140 (0.309) CM-TCS.13S 1SVR730740R0300 0.151 (0.333) CM-TCS.13P 1SVR740740R0300 0.140 (0.309) CM-TCS.21S 1SVR730740R9100 0.138 (0.304) CM-TCS.21P 1SVR740740R9100 0.127 (0.280) CM-TCS.22S 1SVR730740R9200 0.138 (0.304) CM-TCS.22P 1SVR740740R9200 0.127 (0.280) CM-TCS.23S 1SVR730740R9300 0.138 (0.304) CM-TCS.23P 1SVR740740R9300 0.127 (0.280) Ordering details - Temperature monitoring relays C51x range with display and digital setup Rated control supply voltage Measuring range 24 V AC/DC 1SVC 110 000 F0557 24-240 V AC/DC C512, C513 -50...+500 °C 1) 24-240 V AC/DC 1) Type 2) Order code Price Weight (1 pce) 1 pce kg (lb) C512-24 1SAR700100R0005 0.32 (0.71) C512-W 1SAR700100R0010 0.33 (0.73) C513-W 1SAR700110R0010 0.34 (0.75) The measuring range depends on the used sensor type: PT100: -50...+500 °C PT1000: -50...+500 °C NTC: +80...+160 °C (Typ Siemens Matsushita B57272-A333-A1 - 100 °C: 1.8 kW, 25 °C: 32.762 kW) KTY84: -40...+300 °C KTY83: -50...+175 °C Ordering details - Replaceable cover marking for digital devices Use for Language Type Order code Price 5 pces C512 German C512-D 1SVR700101R0100 C512 English C512-E 1SVR700102R0100 C513 German C513-D 1SVR700111R0100 C513 English C513-E 1SVR700112R0100 Weight (1 pce) kg (lb) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/104 2 CM-TCS - Overtemperature monitoring, 1 x 2 c/o contacts j 2CDC 252 008 F0209 Temperature monitoring relays Function diagrams A1-A2 Threshold ϑ1 Hysteresis Measured value Open-circuit principle open 11-14 11-12 21-24 21-22 U: green LED ϑ: red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED ϑ: red LED R: yellow LED Undertemperature monitoring, 1 x 2 c/o contacts j With this configuration, settings via t 1 have no influence on the operating function (t 1 disabled). Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value drops below the adjusted threshold value t 2, the output relays energize. If the measured value exceeds again the adjusted threshold value t 2 plus the adjusted hysteresis, the output relays de-energize. Closed-circuit principle: The behavior is inverse to the one with open-circuit principle. A1-A2 Threshold ϑ1 Hysteresis Threshold ϑ2 Hysteresis Measured value Open-circuit principle open 11-14 11-12 21-24 21-22 U: green LED ϑ: red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED ϑ: red LED R: yellow LED A1-A2 2CDC 252 010 F0209 Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t 2, output relay R2 (prewarning) energizes. If the measured value exceeds the adjusted threshold value t 1, output relay R1 (final switch-off) energizes. If the measured value drops again below the adjusted threshold value t 1 minus the adjusted hysteresis, output relay R1 (final switch-off) de-energizes. If the measured value drops below the adjusted threshold value t 2 minus the adjusted hysteresis, output relay R2 (prewarning) de-energizes. Closed-circuit principle: The behavior is inverse to the one with open-circuit principle. 2CDC 252 009 F0209 Overtemperature monitoring, 2 x 1 c/o contact i Measured value Hysteresis Threshold ϑ2 Open-circuit principle open 11-14 11-12 21-24 21-22 U: green LED ϑ: red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED ϑ: red LED R: yellow LED Temperature window monitoring, 1 x 2 c/o contacts j Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t 1 or drops below the adjusted threshold value t 2, the output relays energize. If the measured value drops again below the adjusted threshold value t 1 minus the adjusted hysteresis or exceeds again the adjusted threshold value t 2 plus the adjusted hysteresis, the output relays deenergize. Closed-circuit principle: The behavior is inverse to the one with open-circuit principle. A1-A2 Measured value Hysteresis Threshold ϑ1 Hysteresis Threshold ϑ2 Open-circuit principle open 11-14 11-12 21-24 21-22 U: green LED ϑ: red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED ϑ: red LED R: yellow LED A1-A2 Threshold ϑ1 Hysteresis Measured value Hysteresis Threshold ϑ2 Open-circuit principle open 11-14 11-12 21-24 21-22 2CDC 252 012 F0209 Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value drops below the adjusted threshold value t 1, output relay R1 (prewarning) energizes. If the measured value drops below the adjusted threshold value t 2, output relay R2 (final switch-off) energizes. If the measured value exceeds again the adjusted threshold value t 2 plus the adjusted hysteresis, output relay R2 (final switch-off) de-energizes. If the measured value exceeds the adjusted threshold value t 1 plus the adjusted hysteresis, output relay R1 (prewarning) de-energizes. Closed-circuit principle: The behavior is inverse to the one with open-circuit principle. 2CDC 252 011 F0209 Undertemperature monitoring, 2 x 1 c/o contact i U: green LED ϑ: red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED ϑ: red LED R: yellow LED Temperature window monitoring, 2 x 1 c/o contact i Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t 1 or drops below the adjusted threshold value t 2, output relay R1 (> t 1) or R2 (< t 2) respectively energizes. If the measured value drops again below the adjusted threshold value t 1 minus the adjusted hysteresis or exceeds again the adjusted threshold value t 2 plus the adjusted hysteresis, output relay R1 (>t 1) or R2 ( 10 W feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. 3 2CDC 276 032 F0007 2 2CDC 276 033 F0007 1 2CDC 271 027 F0007 3 Characteristics –– Output voltages 12 V, 24 V DC –– Adjustable output voltages (devices > 10 W) –– Output currents 0.42 A / 0.83 A / 1.3 A / 2.1 A / 2.5 A / 4.2 A –– Power range 10 W, 30 W, 60 W, 100 W –– Wide range input 100-240 V AC (90-264 V AC, 120-375 V DC) –– High efficiency of up to 89 % –– Low power dissipation and low heating –– Free convection cooling (no forced cooling with ventilators) –– Ambient temperature range during operation -40 °C...+70 °C –– Open-circuit, overload and short-circuit stable –– Integrated input fuse –– U/I characteristic (fold-forward behaviour at overload – no switch-off) –– LEDs for status indication –– Light-grey housing in RAL 7035 –– Approvals / Marks (depending on device, partly pending): A, H, R , E / a, b 1 1 OUTPUT ++/‑‑: terminals ‑ output 2 3 Indication of operational states 2 INPUT L, N: terminals ‑ input DC ON: green LED ‑ output voltage applied DC LOW: red LED ‑ output voltage too low 4 Circuit diagram 5 OUTPUT Adjust: potentiometer ‑ adjustment of output voltage 3 4 5 3/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-D range Ordering details Description 2CDC 271 024 F0007 The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution panels. This range offers devices with output voltages of 12 V DC and 24 V DC at output currents of 0.42 A to 4.2 A. Thanks to a high thermal efficiency corresponding to low power and heat dissipation, the devices can be operated without forced cooling. All devices feature the U/I output characteristic (fold forward behaviour). All power supply units in the CP-D range are approved according to all relevant international standards. Ordering details Input voltage range Rated output voltage / current Type 90-264 V AC/ 120-375 V DC 12 V DC / 0.83 A CP-D 12/0.83 1SVR427041R1000 0.06 (0.13) 90-264 V AC/ 120-375 V DC 12 V DC / 2.1 A CP-D 12/2.1 1SVR427043R1200 0.19 (0.41) 90-264 V AC/ 120-375 V DC 24 V DC / 0.42 A CP-D 24/0.42 1SVR427041R0000 0.06 (0.13) 90-264 V AC/ 120-375 V DC 24 V DC / 1.3 A CP-D 24/1.3 1SVR427043R0100 0.19 (0.41) 90-264 V AC/ 120-375 V DC 24 V DC / 2.5 A CP-D 24/2.5 1SVR427044R0200 0.25 (0.56) 90-264 V AC/ 120-375 V DC 24 V DC / 4.2 A CP-D 24/4.2 1SVR427045R0400 0.32 (0.71) 2CDC 271 025 F0007 CP-D 12/0.83, CP-D 24/0.42 Order code Price 1 pce Weight (1 pce) kg (lb) 2CDC 271 028 F0007 CP-D 12/2.1, CP-D 24/1.3 CP-D 24/2.5 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/10 3 CP-D range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-D 12/0.83 Input circuit - supply circuit Rated input voltage U in 100-240 V AC Input voltage range 90-264 V AC / 120-375 V DC Frequency range AC 3 Typical input current / typical power consumption Inrush current limiting 47-63 Hz at 110 V AC 200 mA / 12.68 W 502 mA / 31.14 W at 230 V AC 128.3 mA / 13.01 W 277 mA / 31.2 W at 230 V AC 30 A (max. 3 ms) 50 A (max. 3 ms) Power failure buffering time min. 30 ms Internal input fuse 1 A slow-acting / 250 V AC Power factor correction (PFC) no Indication of operational states Output voltage CP-D 12/2.1 L, N 2 A slow-acting / 250 V AC DC ON: green LED V : output voltage applied DC LOW: red LED V : output voltage too low Output circuit Rated output voltage 12 V DC +, - Tolerance of the output voltage ±1 % Adjustment range of the output voltage - 12-14 V DC Rated output power 10 W 25 W Rated output current I r Derating of the output current Maximum d eviation with Control time Ta m 60 °C 0.83 A ++, -- 2.1 A 60 °C < Ta m 70 °C 2.5 %/°C load change statical max. 1 % change of output voltage within the input voltage range max. 1 % Starting time after applying the supply voltage Rise time Residual ripple and switching peaks < 1 ms at I r 1000 ms at rated load typ. 1 ms BW = 20 MHz 50 mV Parallel connection yes, using CP-D RU Series connection yes, to increase voltage Resistance to reverse feed 18 V / 1 s Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output U/I characteristic curve Short-circuit protection continuous short-circuit stability Short-circuit behaviour continuation with output power limiting Current limiting at short circuit typ. 1.4 A Overload protection output power limiting Overvoltage protection 15-16.5 V DC No-load protection continuous no-load stability Starting of capacitive loads unlimited General data Efficiency typ. 78 % Duty time 100 % Dimensions (W x H x D) Weight 18 x 91 x 57.5 mm (0.71 x 3.58 x 2.26 in) 0.066 kg (0.13 lb) Material of housing plastic Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class II 3/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 typ. 5.9 A typ. 82 % 53 x 91 x 57.5 mm (2.09 x 3.58 x 2.26 in) 0.196 kg (0.41 lb) CP-D range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-D 12/0.83 CP-D 12/2.1 Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule 0.2-1.5 mm 2 (24-16 AWG) 0.2-2.5 mm 2 (24-14 AWG) rigid 0.2-2.5 mm 2 (26-12 AWG) 4-5 mm (0.16-0.2 in) 0.2-2.5 mm 2 (24-12 AWG) 7 mm (0.28 in) Stripping length Tightening torque 0.6 Nm (5 lb.in) Environmental data Ambient temperature range 0.7 Nm (6 lb.in) operation -40…+70 °C rated load -40…+60 °C storage -40…+85 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 4 x 24 cycles, 40 °C, 95 % RH Vibration (sinusoidal) (IEC/EN 60068-2-6) 50 m/s 2, 10 Hz - 2 kHz Shock (half-sine) (IEC/EN 60068-2-27) 40 m/s 2, 22 ms Isolation data Rated insulation voltage U i input circuit / output circuit 3 kV AC Pollution degree 2 Overvoltage category (UL/IEC/EN 60950-1) ll Standards Product standard EN 61204 Low Voltage Directive 2006/95/EC EMC Direcitve 2004/108/EC Electrical safety UL 508, UL 60950-1, EN 60950-1 Protective low voltage SELV (EN 60950-1) Electromagnetic compatibility Interference immunity to EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 4 (4 kV / 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m) electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV) surge IEC/EN 61000-4-5 Level 3 (2 kV L-L) conducted disturbances, induced by radiofrequency fields Interference emission IEC/EN 61000-4-6 Level 3 (10 V) Level 4 (4 kV / 15 kV) EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B „Approvals and marks“ on page 3/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/12 3 CP-D range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-D 24/0.42 100-240 V AC Input voltage range 90-264 V AC /120-375 V DC Typical input current / typical power consumption Inrush current limiting CP-D 24/4.2 1120 mA / 69.3 W 1800 mA / 117.3 W 47-63 Hz at 110 V AC 184 mA / 11.62 W 600 mA / 37.92 W at 230 V AC 120.6 mA / 12 W 344 mA / 38.16 W 660 mA / 70.1 W 900 mA / 114.4 W at 230 V AC 30 A (max. 3 ms) 50 A (max. 3 ms) 60 A (max. 3 ms) Power failure buffering time min. 30 ms Internal input fuse 1 A slow-acting / 250 V AC no Power factor correction (PFC) Indication of operational states Output voltage CP-D 24/2.5 L, N Frequency range AC 3 CP-D 24/1.3 Input circuit - supply circuit Rated input voltage U in min. 60 ms 2 A slow-acting / 250 V AC 3.15 A slow-acting / 250 V AC DC ON: green LED V : output voltage applied DC LOW: red LED V : output voltage too low Output circuit Rated output voltage 24 V DC Tolerance of the output voltage ±1 % Adjustment range of the output voltage - 24-28 V DC Rated output power 10 W 30 W 60 W 100 W Rated output current I r Ta 60 °C: 0.42 A Ta 60 °C: 1.3 A Ta 55 °C: 2.5 A Ta 60 °C: 4.2 A 60 °C < Ta 70 °C: 2.5 %/°C 55 °C < Ta 70 °C: 2.5 %/°C 60 °C < Ta 70 °C: 2.5 %/°C Derating of the output current Maximum d eviation with Control time +, - 60 °C < Ta 70 °C: 2.5 %/°C load change statical max. 1 % ++, -- change of output voltage within the input voltage range max. 1 % < 1 ms Starting time after applying the supply voltage Rise time Residual ripple and switching peaks at I r 1000 ms at rated load typ. 1 ms BW = 20 MHz 50 mV Parallel connection yes, using CP-D RU Series connection yes, to increase voltage Resistance to reverse feed 35 V / 1 s Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output U/I characteristic curve Short-circuit protection continuous short-circuit stability Short-circuit behaviour continuation with output power limiting Current limiting at short circuit typ. 0.78 A Overload protection output power limiting Overvoltage protection 30-33 V DC No-load protection continuous no-load stability Starting of capacitive loads unlimited General data Efficiency typ. 80 % Duty time 100 % Dimensions (W x H x D) Weight 18 x 91 x 57.5 mm (0.71 x 3.58 x 2.26 in) 0.066 kg (0.13 lb) Material of housing plastic Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position typ. 4.2 A typ. 6.05 A typ. 11.5 A typ. 83 % typ. 86 % typ. 89 % 53 x 91 x 57.5 mm (2.09 x 3.58 x 2.26 in) 0.196 kg (0.41 lb) 71 x 91 x 57.5 mm (2.80 x 3.58 x 2.26 in) 0.252 kg (0.55 lb) 89.9 x 91 x 57,5 mm (3.54 x 3.58 x 2.26 in) 0.386 kg / (0.72 lb) horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class II 3/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-D range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-D 24/0.42 CP-D 24/1.3 CP-D 24/2.5 CP-D 24/4.2 Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule 0.2-1.5 mm 2 0.2-2.5 mm 2 (24-14 AWG) (24-16 AWG) rigid 0.2-2.5 mm 2 0.2-2.5 mm 2 (24-12 AWG) (26-12 AWG) Stripping length 4-5 mm (0.16-0.2 in) 7 mm (0.28 in) Tightening torque 0.6 Nm (5 lb.in) 3 0.7 Nm (6 lb.in) Environmental data Ambient temperature range operation -40…+70 °C rated load -40…+60 °C -40…+55 °C -40…+60 °C 4 kV AC 3 kV AC storage -40…+85 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 4 x 24 cycles, 40 °C, 95 % RH Vibration (sinusoidal) (IEC/EN 60068-2-6) 50 m/s 2, 10 Hz - 2 kHz Shock (half-sine) (IEC/EN 60068-2-27) 40 m/s 2, 22 ms Isolation data Rated insulation voltage U i input circuit / output circuit 3 kV AC Pollution degree 2 Overvoltage category (UL/IEC/EN 60950-1) ll Standards Product standard EN 61204 Low Voltage Directive 2006/95/EC EMC Direcitve 2004/108/EC Electrical safety UL 508, UL 60950-1, EN 60950-1 Protective low voltage SELV (EN 60950-1) Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field EN 61000-6-2 IEC/EN 61000-4-2 Level 4 (4 kV / 8 kV) IEC/EN 61000-4-3 Level 3 (10 V/m) electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV) surge IEC/EN 61000-4-5 Level 3 (2 kV L-L) conducted disturbances, induced by radiofrequency fields Interference emission IEC/EN 61000-4-6 Level 3 (10 V) Level 4 (4 kV / 15 kV) Level 4 (4 kV / 8 kV) EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B „Approvals and marks“ on page 3/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/14 CP-D range Technical diagrams 0.75 1 1.25 Iout [A] 0 Uout [V] 24 22 20 18 16 14 12 10 8 6 4 2 0 0.125 0.25 0.375 0.5 0.625 CP-D 24/0.42 0.75 0.875 Iout [A] 2CDC 272 021 F0207 Uout [V] 24 22 20 18 16 14 12 10 8 6 4 2 0 0 1 1.5 2 2.5 3 3.5 4 Iout [A] 2CDC 272 023 F0207 Uout [V] 24 22 20 18 16 14 12 10 8 6 4 2 0 0.5 1.5 2 2.5 1.5 2 4 5 1 0 1 2 3 -10 0 10 20 30 40 CP-D except CP-D 24/2.5 50 60 70 Ta [°C] 100 90 80 70 60 50 40 30 20 10 -10 0 10 20 30 40 50 CP-D 24/2.5 3/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 60 70 Ta [°C] 2CDC 272 018 F0207 Pout [%] 100 90 80 70 60 50 40 30 20 10 3.5 2.5 6 CP-D 24/4.2 Characteristic curve of temperature at rated output voltage Pout [%] 3 4 Iout [A] 3 CP-D 24/1.3 Uout [V] 0 1 0.5 0 24 22 20 18 16 14 12 10 8 6 4 2 0 CP-D 24/2.5 0.5 CP-D 12/2.1 7 Iout [A] 8 Iout [A] 2CDC 272 022 F0207 0.5 2CDC 272 030 F0207 0.25 0 CP-D 12/0.83 2CDC 272 019 F0207 Uout [V] 12 11 10 9 8 7 6 5 4 3 2 1 0 2CDC 272 018 F0207 3 Uout [V] 12 11 10 9 8 7 6 5 4 3 2 1 0 2CDC 272 020 F0207 Characteristic curve of output at Ta = 25 °C CP-D range Dimensional drawings Dimensional drawings dimensions in mm 18,0 [0.71”] 53,0 [2.09”] 3 67,0 [2.64”] 44,5 [1.75”] 67,0 [2.64”] CP-D 12/0.83, CP-D 24/0.42 2CDC 272 012 F0b07 32,1 [1.26”] 49,0 [1.93”] 57,5 [2.26”] 91,0 [3.58”] 2CDC 272 011 F0b07 57,5 [2.26”] 49,0 [1.93”] 32,1 [1.26”] 91,0 [3.58”] 44,5 [1.75”] CP-D 12/2.1, CP-D 24/1.3 71,0 [2.80”] 89,9 [3.54”] 67,0 [2.64”] 67,0 [2.64”] 44,5 [1.75”] CP-D 24/2.5 2CDC 272 014 F0b07 57,5 [2.26”] 49,0 [1.93”] 32,1 [1.26”] 91,0 [3.58”] 2CDC 272 013 F0b07 57,5 [2.26”] 49,0 [1.93”] 32,1 [1.26”] 91,0 [3.58”] 44,5 [1.75”] CP-D 24/4.2 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/16 CP-E range Product group picture 3 3/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-E range Table of contents CP-E range Product group picture 3/17 Table of contents 3/18 Benefits and advantages 3/19 Ordering details 3/20 Technical data 3/21 Technical diagrams, Wiring instructions 3/29 Technical diagrams, Dimensional drawings 3/30 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/18 3 CP-E range Benefits and advantages Signalling output/contact 1 The CP-E range 24 V devices > 18 W offer an output/contact for monitoring of the output v oltage and remote diagnosis. Wide range input 2 Optimised for world-wide applications: The CP-E power supplies can be supplied within a wide range of AC or DC voltage. Adjustable output voltage 3 The CP-E range types feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. Redundancy units 4 For decoupling of parallelized power supply units m 40 V. Thus, true redundancy can be achieved. Further information about redundancy unit on page 51. 4 1 2CDC 271 006 F0003 3 2CDC 276 008 F0006 2 Benefits 2CDC 276 009 F0006 1 2CDC 276 008 F0006 3 Characteristics –– Output voltages 5 V, 12 V, 24 V, 48 V DC –– Adjustable output voltages –– Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / 3 A / 5 A / 10 A / 20 A –– Power range 15 W, 18 W, 30 W, 60 W, 120 W, 240 W, 480 W –– High efficiency of up to 90 % –– Low power dissipation and low heating –– Free convection cooling (no forced cooling with ventilators) –– Ambient temperature range during operation -40...+70 °C –– Open-circuit, overload and short-circuit stable –– Integrated input fuse –– U/I characteristic curve on devices > 18 W (fold-forward behaviour at overload – no switch-off) –– Redundancy units offering true redundancy –– LED(s) for status indication –– Signalling output/contact for output voltage OK Transistor on 24 V devices > 18 W and < 120 W –– Solid-state on 24 V devices M 120 W –– Approvals / Marks (depending on device, partly pending): –– A, H, R , E / a, b 1 INPUT L, N, PE: terminals ‑ input 2 Circuit diagram 3 single/parallel: sliding switch - adjustment of single or parallel operation 4 Indication of operational states 2 DC ON: green LED ‑ green LED ‑ output voltage OK DC LOW: red LED ‑ output voltage too low 5 OUTPUT L+, L+, L‑, L-: terminals ‑ output OUTPUT Adjust: potentiometer ‑ adjustment of output voltage 3 4 5 3/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-E range Ordering details Description This range offers types with output voltages from 5 V DC to 48 V DC at output currents of 0.625 A to 20 A. The high thermal efficiency of up to 90 %, corresponding to very low power and heat dissipation, allows operation without forced cooling. The functionality has been enhanced while the number of different types has been considerably reduced. Of course all power supplies of the CP-E range are approved in accordance with all relevant international standards. 3 Ordering details - CP-E < 100 W 2CDC 271 017 F0006 Input voltage range CP-E 24/0.75 Rated output voltage / current Type Order code Price 90-264 V AC / 120-375 V DC 5 V DC / 3 A CP-E 5/3.0 1SVR427033R3000 0.15 (0.33) 85-264 V AC / 90-375 V DC 12 V DC / 2.5 A CP-E 12/2.5 1SVR427032R1000 0.29 (0.64) 90-132 V AC, 180-264 V AC / 210-375 V DC 12 V DC / 10 A CP-E 12/10.0 1SVR427035R1000 1.00 (2.20) 90-264 V AC / 120-375 V DC 24 V DC / 0.75 A CP-E 24/0.75 1SVR427030R0000 0.15 (0.33) 85-264 V AC / 90-375 V DC 24 V DC / 1.25 A CP-E 24/1.25 1SVR427031R0000 0.29 (0.64) 85-264 V AC / 90-375 V DC 24 V DC / 2.5 A CP-E 24/2.5 1SVR427032R0000 0.36 (0.79) Rated output voltage / current Type Order code 90-132 V AC, 180-264 V AC / 210-375 V DC 24 V DC / 5 A CP-E 24/5.0 1SVR427034R0000 1.00 (2.20) 90-132 V AC, 180-264 V AC / 210-375 V DC 24 V DC / 10 A CP-E 24/10.0 1SVR427035R0000 1.36 (3.01) 90-264 V AC / 120-375 V DC 24 V DC / 20 A CP-E 24/20.0 1SVR427036R0000 1.90 (4.18) 85-264 V AC / 90-375 V DC 48 V DC / 0.625 A CP-E 48/0.62 1SVR427030R2000 0.29 (0.64) 85-264 V AC / 90-375 V DC 48 V DC / 1.25 A CP-E 48/1.25 1SVR427031R2000 0.36 (0.79) 90-132 V AC, 180-264 V AC / 210-375 V DC 48 V DC / 5 A CP-E 48/5.0 1SVR427034R2000 1.36 (3.01) 90-264 V AC / 120-375 V DC 48 V DC / 10 A CP-E 48/10.0 1SVR427035R2000 1.90 (4.19) 1 pce Weight (1 pce) kg (lb) Ordering details - CP-E M 120 W 2CDC 271 013 F0006 Input voltage range 2CDC 271 028 F0008 CP-E 12/2.5 CP-E 48/5.0 Price 1 pce Weight (1 pce) kg (lb) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/20 CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 5/3.0 Input circuit Rated input voltage U in CP-E 12/10.0 L, N 100-240 V AC Input voltage range 90-264 V AC / 120-375 V DC Frequency range AC 3 CP-E 12/2.5 115 / 230 V AC auto select 90-132 V AC, 180-264 V AC / 210-375 V DC 85-264 V AC / 90-375 V DC 47-63 Hz Typical input current at 115 V AC 335 mA 560 mA 2.2 A at 230 V AC 210 mA 330 mA 0.83 A 35.9 W 143 W at 115 V AC 10 A (max. 3 ms) 20 A (max. 3 ms) 24 A (max. 5 ms) at 230 V AC 18 A (max. 3 ms) 40 A (max. 3 ms) 48 A (max. 5 ms) at 115 V AC min. 20 ms min. 20 ms min. 25 ms at 230 V AC min. 75 ms min. 30 ms min. 30 ms Typical power consumption 19.8 W Inrush current limiting Discharge current input / output 0.25 mA input / PE 3.5 mA Power failure buffering time Internal input fuse 2 A slow-acting / 250 V AC Power factor correction (PFC) no Indication of operational states Output voltage green LED OK: V : output voltage OK red LED LOW: V : output voltage too low L+,L- Output circuit 3.15 A slow-acting / 250 V AC yes, passive, 0.7 OUTPUT OK: V : output voltage OK - OUTPUT OK: V : output voltage OK OUTPUT LOW: V : output voltage too low L+, L+, L-, L- Rated output voltage 5 V DC Tolerance of the output voltage 0...+1 % Adjustment range of the output voltage 4.5-5.75 V DC 12-14 V DC 11.4-14.5 V DC Rated output power 15 W 30 W 120 W 2.5 A 10 A Rated output current I r Ta m 60 °C 3.0 A 60 °C < Ta m 70 °C 2.5 %/°C load change statical ±2 % Derating of the output current Maximum deviation with Control time ±0.5 % with 3500 µF - max. 2 s - with 7000 µF max. 1.5 s - max. 1.5 s with 3500 µF - max. 500 ms - with 7000 µF max. 500 ms - max. 500 ms change of output voltage within the ±1 % input voltage range < 2 ms ±0.5 % at I r max. 1 s at rated load max. 150 ms Fall time Residual ripple and switching peaks 2.5 %/°C ±1 % (single mode) ±5 % (parallel mode) ±0.5 % Starting time after applying the supply voltage Rise time 12 V DC max. 150 ms BW = 20 MHz 50 mV Parallel connection yes, to enable redundancy Series connection yes, to increase voltage Resistance to reverse feed 1 s - max. 7.5 V DC 1 s - max.18 V DC Characteristic curve of output Hiccup-mode U/I characteristic curve Short-circuit protection continuous short-circuit proof Short-circuit behaviour Hiccup-mode Overload protection output power limiting No-load protection continuous no-load stability Starting of capacitive loads 7000 µF configurable, to increase power,up to 3 devices, min. 0.1 I r - max. 0.9 I r yes, to increase voltage, max. 2 devices max. 18 V DC Output circuit - No-load, overload and short-circuit behaviour 3/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 continuation with output power limiting 3500 µF 7000 µF CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 5/3.0 CP-E 12/2.5 CP-E 12/10.0 General data Power dissipation typ. 5 W typ. 5.6 W typ. 24 W Efficiency typ. 75 % typ. 84 % typ. 84 % Duty time 100 % Dimensions (W x H x D) Weight 22.5 x 90 x 114 mm (0.89 x 3.54 x 4.49 in) 0.144 kg (0.317 lb) 40.5 x 90 x 114 mm (1.59 x 3.54 x 4.49 in) 0.287 kg (0.633 lb) 63.2 x 123.6 x 123.6 mm (2.49 x 4.87 x 4.87 in) 0.888 kg (1.958 lb) Material of housing Plastic Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position Metal horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection - input circuit / output circuit Wire size fine-strand with wire end ferrule 0.2-2.5 mm 2 (24-14 AWG) fine-strand without wire end ferrule 0.2-4 mm² (24-11 AWG) 0.2-6 mm² (24-10 AWG) rigid Stripping length Tightening torque Environmental data Ambient temperature range 6 mm (0.24 in) 8 mm (0.31 in) input / output 0.6 Nm (5 lb.in) 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in) operation -20…+70 °C -40…+70 °C -35…+70 °C rated load -20...+60 °C -40...+60 °C -35...+60 °C storage -20…+85 °C -40…+85 °C -40…+85 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 RH, % without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage U i input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC Pollution degree 2 Overvoltage category (UL/IEC/EN 60950-1) II Standards Product standard EN 61204-3 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC RoHS directive 2011/65/EC Electrical safety EN 60950-1, UL 60950-1, UL 508 SELV (EN 60950) Protective low voltage Electromagnetic compatibility Interference immunity to EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1 IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, electromagnetic field electrical fast transient/burst IEC/EN 61000-4-3 Level 3 (10 V/m) IEC/EN 61000-4-4 Level 4 (4 kV / 2,5 kHz) Level 4 (4 kV / 5 kHz) surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV) conducted disturbances, induced by radiofrequency fields power frequency magnetic fields IEC/EN 61000-4-6 Level 3 (10 V) IEC/EN 61000-4-8 Level 4 (30 A/m) voltage dips, short interruptions and voltage variations Interference emission high-frequency radiated IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms interruptions: >95 % 5000 ms IEC/EN 61000-6-3 IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B limits for harmonic current emissions IEC/EN 61000-3-2 Class D Class A Class D „Approvals and marks“ on page 3/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/22 3 CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 24/0.75 Input circuit Rated input voltage U in CP-E 24/2.5 L, N 100-240 V AC Input voltage range 90-264 V AC / 120-375 V DC Frequency range AC 85-264 V AC / 90-375 V DC 47-63 Hz Typical input current 3 CP-E 24/1.25 at 115 V AC 335 mA 560 mA 1060 mA at 230 V AC 210 mA 330 mA 590 mA 36.7 W 69.2 W at 115 V AC 10 A (max. 3 ms) 20 A (max. 3 ms) 20 A (max. 3 ms) at 230 V AC 18 A (max. 3 ms) 40 A (max. 3 ms) 40 A (max. 3 ms) Typical power consumption 22.8 W Inrush current limiting Discharge current input / output 0.25 mA input / PE 3.5 mA Power failure buffering time at 115 V AC min. 20 ms min. 20 ms at 230 V AC min. 75 ms min. 30 ms Internal input fuse 2 A slow-acting / 250 V AC Power factor correction (PFC) no Indication of operational states Output voltage green LED OK: V : output voltage OK red LED LOW: V : output voltage too low OUTPUT OK: V : output voltage OK - L+,L- - Output circuit Rated output voltage 24 V DC Tolerance of the output voltage 0 ... +1 % Adjustment range of the output voltage 21.6-28.8 V DC 24-28 V DC Rated output power 18 W 30 W 60 W 1.25 A 2.5 A Rated output current I r Ta m 60 °C 0.75 A 60 °C < Ta m 70 °C 2.5 %/°C DC OK - Derating of the output current Signalling output for output voltage OK Maximum deviation with Control time load change statical ±2 % change of output voltage within the ±1 % input voltage range < 2 ms Starting time after applying the supply voltage Rise time transistor ±0.5 % ±0.5 % at I r max. 1 s with 3500 µF - max. 2 s - with 7000 µF max. 1.5 s - max. 1.5 s with 3500 µF - max. 500 ms - with 7000 µF max. 500 ms - max. 500 ms at rated load max. 150 ms Fall time Residual ripple and switching peaks L+, L+, L-, L- max. 150 ms BW = 20 MHz 50 mV Parallel connection Series connection Resistance to reverse feed Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output yes, to enable redundancy yes, to increase voltage 1 s - max. 35 V DC Short-circuit protection continuous short-circuit proof Short-circuit behaviour Hiccup-mode Overload protection output power limiting No-load protection continuous no-load stability Starting of capacitive loads 7000 µF Hiccup-mode 3/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 U/I characteristic curve continuation with output power limiting 3500 µF 7000 µF CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type General data Power dissipation CP-E 24/0.75 typ. 4.45 W typ. 5.5 W typ. 8.8 W Efficiency typ. 77 % typ. 86 % typ. 89 % Duty time 100 % Dimensions (W x H x D) 22.5 x 90 x 114 mm (0.89 x 3.54 x 4.49 in) 40.5 x 90 x 114 mm (1.59 x 3.54 x 4.49 in) Weight 0.143 kg (0.315 lb) 0.270 kg (0.60 lb) Material of housing Plastic Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position CP-E 24/1.25 CP-E 24/2.5 0.331 kg (0.73 lb) horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection - input circuit / output circuit Wire size fine-strand with wire end ferrule 0.2-2.5 mm 2 (24-14 AWG) fine-strand without wire end ferrule rigid Stripping length 6 mm (0.24 in) Tightening torque input / output 0.6 Nm (5 lb.in) Environmental data Ambient temperature range operation -20…+70 °C -40…+70 °C rated load -20…+60 °C -40…+60 °C storage -20…+85 °C -40…+85 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % RH, without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage U i input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC Pollution degree 2 Overvoltage category (UL/IEC/EN 60950-1) II Standards Product standard EN 61204-3 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC RoHS directive 2011/65/EC Electrical safety EN 50178, EN 60950-1, UL 60950-1, UL 508 Protective low voltage SELV (EN 60950) Electromagnetic compatibility Interference immunity to electrostatic discharge EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1 IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m) electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV / 2.5 kHz) Level 4 (4 kV / 5 kHz) surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV) conducted disturbances, induced by radiofrequency fields IEC/EN 61000-4-6 Level 3 (10 V) power frequency magnetic fields voltage dips, short interruptions and voltage variations Interference emission IEC/EN 61000-4-8 Level 4 (30 A/m) IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms, interruptions: >95 % 5000 ms IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B limits for harmonic current emissions IEC/EN 61000-3-2 Class D Class A „Approvals and marks“ on page 3/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/24 3 CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 24/5.0 Input circuit Rated input voltage U in CP-E 24/20.0 L, N Input voltage range Frequency range AC Typical input current 3 CP-E 24/10.0 115-230 V AC 90-132 V AC, 180-264 V AC / 210-375 V DC 47-63 Hz 90-132 V AC, 180-264 V AC / 210-375 V DC 90-264 V AC, 120-375 V DC at 115 V AC 2.2 A 4.0 A 4.9 A at 230 V AC 0.83 A 1.55 A 2.5 A 140 W 270 W 539 W at 115 V AC 24 A (max. 5 ms) 30 A (max. 5 ms) 25 A (max. 5 ms) at 230 V AC 48 A (max. 5 ms) 60 A (max. 5 ms) 50 A (max. 5 ms) 6.3 A slow-acting / 250 V AC 10 A slow-acting / 250 V AC Typical power consumption Inrush current limiting Discharge current 115 / 230 V AC auto select input / output 0.25 mA input / PE 3.5 mA Power failure buffering time at 115 V AC min. 25 ms at 230 V AC min. 30 ms Internal input fuse 3.15 A slow-acting / 250 V AC Power factor correction (PFC) yes, passive, 0.7 Indication of operational states Output voltage yes, active 115 V AC: 0.99 230 V AC: 0.97 green LED OUTPUT OK: V : output voltage OK red LED OUTPUT LOW: V : output voltage too low Output circuit Rated output voltage 24 V DC L+, L+, L-, L- Tolerance of the output voltage 0...+1 % Adjustment range of the output voltage 22.5-28.5 V DC Rated output power 120 W Rated output current I r Ta m 60 °C 5 A Ta m 55 °C - Derating of the output current 60 °C < Ta m 70 °C 2.5 %/°C 55 °C < Ta m 70 °C - Signalling contact for output voltage OK 240 W 480 W 10 A - - 20 A - - 2.5 %/°C 13-14 solid-state (max. 60 V DC, 0.3 A) Minimum fuse rating to achieve short-circuit protection 13-14 M 60 V DC, m 0.3 A fast-acting load change statical ±1 % (single mode), ±5 % (parallel mode) Maximum deviation with Control time change of output voltage within ±0.5 % the input voltage range < 2 ms Starting time after applying the supply voltage Rise time at I r max. 1 s with 3500 µF max. 1.5 s - with 7000 µF - max. 1.5 s at rated load max. 150 ms with 3500 µF max. 500 ms - with 7000 µF - max. 500 ms Fall time Residual ripple and switching peaks - - max. 150 ms BW = 20 MHz 50 mV 100 mV Parallel connection configurable, to increase power, up to 3 devices, min. 0.1 Ir - max. 0.9 Ir Series connection yes, to increase voltage, max. 2 devices Resistance to reverse feed max. 35 V DC Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output U/I characteristic curve Short-circuit protection continuous short-circuit proof Short-circuit behaviour continuation with output power limiting Overload protection output power limiting No-load protection continuous no-load stability Starting of capacitive loads 3500 µF 3/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 7000 µF CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 24/5.0 CP-E 24/10.0 CP-E 24/20.0 General data Power dissipation typ. 20 W typ. 35 W typ. 63 W Efficiency typ. 86 % typ. 89 % typ. 89 % Duty time 100 % Dimensions (W x H x D) 63.2 x 123.6 x 123.6 mm (2.49 x 4.87 x 4.87 in) 83 x 123.6 x 123.6 mm (3.27 x 4.87 x 4.87 in) 175 x 123.6 x 123.6 mm (6.89 x 4.87 x 4.87 in) Weight 0.882 kg (1.945 lb) 1.334 kg (2.941 lb) 1.850 kg (4.079 lb) Material of housing Metal Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection - input circuit / output circuit Wire size fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG) fine-strand without wire end 0.2-6 mm² (24-10 AWG) ferrule rigid Stripping length Tightening torque Environmental data Ambient temperature range 8 mm (0.31 in) input / output 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in) operation -35…+70 °C -40…+70 °C rated load -35…+60 °C -40…+60 °C storage -40…+85 °C -40…+85 °C -40…+55 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 %RH, without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage U i input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC signalling contact / PE 0.5 kV DC Pollution degree 2 Overvoltage category (UL/IEC/EN 60950-1) II Standards Product standard EN 61204-3 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC RoHS directive 2011/65/EC Electrical safety EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1 SELV (EN 60950) Protective low voltage Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, electromagnetic field electrical fast transient/burst IEC/EN 61000-4-3 Level 3 (10 V/m) IEC/EN 61000-4-4 Level 4 (4 kV / 5 kHz) surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV) conducted disturbances, induced by radiofrequency fields power frequency magnetic fields IEC/EN 61000-4-6 Level 3 (10 V) voltage dips, short interruptions and voltage variations Interference emission IEC/EN 61000-4-8 Level 4 (30 A/m) IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms interruptions: >95 % 5000 ms IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B limits for harmonic current emissions Level 4 (4 kV / 2.5 kHz) Class D „Approvals and marks“ on page 3/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/26 3 CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 48/0.62 Input circuit Rated input voltage U in 3 Typical power consumption Inrush current limiting Discharge current Power failure buffering time 85-264 V AC / 90-375 V DC 47-63 Hz at 115 V AC 560 mA at 230 V AC 330 mA 35.7 W 4.0 A 4.9 A 1.55 A 2.5 A 69.0 W 267 W min. 25 ms 10 A slowacting / 250 V AC yes, active yes, passive, 0.7 115 V AC: 0.99 230 V AC: 0.97 green LED OUTPUT OK: V : output voltage OK red LED OUTPUT LOW: V : output voltage too low L+, L+, L-, L48 V DC Tolerance of the output voltage 0...+1 % Adjustment range of the output voltage 48-55 V DC Rated output power 30 W Rated output current I r Ta m 60 °C 0.625 A Ta m 55 °C 60 °C < Ta m 70 °C 2.5 %/°C 55 °C < Ta m 70 °C DC OK load change statical 47-56 V DC 60 W 240 W 480 W 1.25 A 5A - - - 10 A - - - ±1 % (single mode) ±5 % (parallel mode) - ±0.5 % change of output voltage within ±0.5 % the input voltage range Control time < 2 ms Starting time after applying the supply voltage at I r max. 1 s with 3500 µF max. 2 s with 7000 µF - Fall time Residual ripple and switching peaks min. 25 ms 6.3 A slowacting / 250 V AC no Output circuit Rated output voltage Rise time 90-264 V AC, 120-375 V DC 590 mA 2 A slow-acting / 250 V AC Indication of operational states Output voltage Maximum deviation with 115-230 V AC 1060 mA input / PE 3.5 mA at 115 V AC min. 20 ms at 230 V AC min. 30 ms Power factor correction (PFC) Signalling output for output voltage OK CP-E 48/10.0 528 W at 115 V AC 20 A (max. 3 ms) 20 A (max. 3 ms) 30 A (max. 5 ms) 25 A (max. 5 ms) at 230 V AC 40 A (max. 3 ms) 40 A (max. 3 ms) 60 A (max. 5 ms) 50 A (max. 5 ms) input / output 0.25 mA Internal input fuse Derating of the output current CP-E 48/5.0 L, N 115 / 230 V AC auto select 90-132 V AC, 180-264 V AC / 210-375 V DC 100-240 V AC Input voltage range Frequency range AC Typical input current CP-E 48/1.25 at rated load max. 150 ms with 3500 µF max. 500 ms with 7000 µF - ±0.5 % - - max. 1.5 s max. 1.5 s - - max. 500 ms max. 500 ms max. 150 ms BW = 20 MHz 50 mV yes, to enable redundancy - yes, to increase voltage configurable, to increase power, up to 3 devices, min. 0.1 I r - max. 0.9 I r yes, to increase voltage, max. 2 devices Resistance to reverse feed 1 s - max. 63 V DC Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output U/I characteristic curve Short-circuit protection continuous short-circuit proof Short-circuit behaviour continuation with output power limiting Overload protection output power limiting No-load protection continuous no-load stability Starting of capacitive loads 3500 µF 3/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 - 100 mV Parallel connection Series connection 2.5 %/°C 7000 µF unlimited 7000 µF CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 48/0.62 General data Power dissipation Efficiency Duty time Dimensions (W x H x D) typ. 4.9 W typ. 86 % 100 % CP-E 48/1.25 typ. 7.8 W typ. 89 % CP-E 48/5.0 typ. 32 W typ. 90 % CP-E 48/10.0 typ. 60 W Weight 83 x 123.6 x 123.6 mm (3.27 x 4.87 x 4.87 in) 0.264 kg (0.582 lb) 0.316 kg (0.697 lb) 1.322 kg (2.915 lb) Material of housing Plastic Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool 40.5 x 90 x 114 mm (1.59 x 3.54 x 4.49 in) Mounting position 175 x 123.6 x 123.6 mm (6.89 x 4.87 x 4.87 in) 1.839 kg (4.054 lb) Metal horizontal horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) housing / terminals IP/20 / IP20 Minimum distance to other units Degree of protection Protection class I Electrical connection - input circuit / output circuit Wire size fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG) fine-strand without wire end ferrule 0.2-2.5 mm² (24-14 AWG) rigid Stripping length Tightening torque Environmental data Ambient temperature range 6 mm (0.24 in) input / output 0.6 Nm (5 lb.in) 0.2-6 mm² (24-10 AWG) 8 mm (0.31 in) 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in) operation -40…+70 °C rated load -40…+60 °C storage -40…+85 °C -40…+55 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % RH, without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage U i input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC Pollution degree 2 Overvoltage category (UL/IEC/EN 60950-1) II Standards Product standard EN 61204-3 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC RoHS directive 2011/65/EC Electrical safety EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1 Protective low voltage SELV (EN 60950) Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge conducted disturbances, induced by radiofrequency fields power frequency magnetic fields voltage dips, short interruptions and voltage variations Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV) IEC/EN 61000-4-3 Level 3 (10 V/m) IEC/EN 61000-4-4 Level 4 (4 kV / 5 kHz) Level 4 (4 kV / 2.5 kHz) IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV) IEC/EN 61000-4-6 Level 3 (10 V/m) IEC/EN 61000-4-8 Level 4 (30 A/m) IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms, interruptions: >95 % 5000 ms IEC/EN 61000-6-3 IEC/CISPR 22, EN 55022 Class B IEC/CISPR 22, EN 55022 Class B Class A Class D „Approvals and marks“ on page 3/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/28 3 CP-E range Technical diagrams, Wiring instructions Output curve at Ta = 25 °C Uout [V] 14 13 12 11 10 9 8 7 6 5 3.2 3.3 3.4 3.5 3.6 3.7 Iout [A] 2 2 CP-E 12/2.5 4 6 8 10 12 14 16 Iout [A] CP-E 12/10.0 Uout [V] CP-E 24/1.25 Uout [V] Uout [V] 28 28 24 24 20 20 16 16 12 12 8 8 4 2CDC 272 007 F0b07 2.75 2.85 2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65 Iout [A] 1.25 1.35 1.45 1.55 1.65 1.75 1.85 1.95 2.05 2.15 Iout [A] 1 2 3 4 5 6 7 8 Iout [A] Iout [A] 1.33 1.41 1.49 1.57 1.65 1.73 1.81 1.89 1.97 2.05 Iout [A] 4 2 4 CP-E 24/10.0 Uout [V] Uout [V] Uout [V] 28 70 70 24 60 60 20 50 50 16 40 40 12 30 30 8 20 20 10 10 8 12 16 20 24 28 32 Iout [A] 0.665 0.705 0.745 0.785 0.825 0.865 0.905 0.945 0.985 1.025 Iout [A] CP-E 24/20.0 CP-E 48/0.62 Uout [V] Uout [V] 56 56 48 48 40 40 32 32 24 24 16 16 8 1 2 3 4 5 6 7 8 Iout [A] CP-E 48/1.25 8 2 CP-E 48/5.0 4 6 8 10 12 14 CP-E 48/10.0 Wiring instructions 5 V Signal DC OK DC OK L- L- 2.2 k 0.5 W 5.1 V 0.3 W 2CDC 272 017 F0207 Relay RL > 700 CP-E 24/1.25, CP-E 24/2.5 3/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 16 Iout [A] 2CDC 272 010 F0b08 4 2CDC 272 009 F0b07 CP-E 24/5.0 2CDC 272 008 F0b08 CP-E 24/2.5 4 2CDC 272 006 F0b07 3.1 2CDC 272 007 F0b08 3.0 2CDC 272 010 F0b07 2.9 2CDC 272 006 F0b08 2.8 2CDC 272 008 F0b07 1 2CDC 272 005 F0b08 4 3 2CDC 272 009 F0b08 3 Uout [V] Uout [V] 15 6 8 10 12 14 16 CP-E range Technical diagrams, Dimensional drawings Temperature behaviour at Ta = 25 °C Pout [%] -35 60 70 2CDC 272 015 F0211 100 90 80 70 60 50 40 30 20 10 Ta [°C] CP-E 12/10.0, CP-E 24/5.0 100 90 80 70 60 50 40 30 20 10 3 -40 70 55 Ta [°C] 2CDC 272 018 F0211 Pout [%] CP-E 24/20.0, CP-E 48/10.0 Pout [%] -20 60 70 2CDC 272 016 F0211 100 90 80 70 60 50 40 30 20 10 Ta [°C] CP-E 5/3.0, CP-E 24/0.75 60 70 Ta [°C] dimensions in mm 22.5 4.49“ 0.89“ 40.5 1.59” 63,2 [2.49“] 123,6 [4.87“] 83,0 [3.27“] 175,0 [6.89“] CP-E 12/10.0, CP-E 24/5.0 123,6 [4.87“] 123,6 [4.87“] CP-E 24/10.0, CP-E 48/5.0 2CDC 272 013 F008 12/2.5, 24/1.25, 24/2.5, 48/0.62, 48/1.25 123,6 [4.87“] 2CDC 272 021 F0011 CP-E CP-E CP-E CP-E CP-E 2CDC 272 013 F0b08 CP-E 5/3.0, CP-E 24/0.75 3.54” 116,6 [4.59“] 90 3.54“ 114 -40 CP-E 12/2.5, CP-E 24/1.25, CP-E 48/0.62, CP-E 24/2.5, CP-E 48/1.25, CP-E 24/10.0, CP-E 48/5.0 90 Dimensional drawings 100 90 80 70 60 50 40 30 20 10 2CDC 272 017 F0211 Pout [%] CP-E 24/20.0, CP-E 48/10.0 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/30 CP-T range Product group picture 3 3/31 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-T range Table of contents CP-T range Product group picture 3/31 Table of contents 3/32 Benefits and advantages 3/33 Ordering details 3/34 Technical data 3/35 Technical diagrams, Dimensional drawings 3/39 Technical diagrams 3/40 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/32 3 CP-T range Benefits and advantages 1 Benefits Signalling output 1 The devices of the CP-T series offer a solid state output for function monitoring and remote diagnostics. Wide input range Wide range input optimized for world-wide applications: The CP-T power supplies can be used in 340 - 575 V AC or 480 - 820 V DC supply systems. Adjustable output voltage 2 The CP-T range feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. 480 W variants: -30...+70°C 2 2CDC 271 043 S0009 1) 2CDC 271 043 S0009 3 Characteristics –– Rated output voltages 24 V, 48 V DC –– Output voltage adjustable via front-face rotary potentiometer “OUTPUT Adjust” –– Rated output currents 5 A, 10 A, 20 A, 40 A –– Rated output powers 120 W, 240 W, 480 W, 960 W –– Three-phase operation (see derating note) –– Two-phase operation (25 % derating possible, see derating note) –– Supply range 3 x 400–500 V AC (3 x 340–575 V AC, 480–820 V DC) –– Typical efficiency of 93 % –– Low power dissipation and low heating –– Free convection cooling (no forced cooling with ventilators) –– Ambient temperature range during operation -40...+70 °C 1) –– Open-circuit, overload and short-circuit stable –– Integrated input fuse –– Redundancy unit CP-A RU offering true redundancy, available as accessory –– LEDs for status indication –– Signalling contact "13-14" (solid state) for output voltage OK –– Approvals / marks (depending on device, partly pending): –– A, H, R , E / a , b 1 Circuit diagram 2 Indication of operational states DC ON: green LED ‑ green LED ‑ output voltage OK DC LOW: red LED ‑ output voltage too low 3 single/parallel: sliding switch - adjustment of single or parallel operation 1 4 Configuration of single or parallel operation 5 Signalling contact OUTPUT 13-14: terminals - signalling contact A solid-state output indicates the error-free operation of the output voltage. OUTPUT L+, L+, L-, L-: terminals - output 2 3 4 5 7 3/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 7 INPUT L1, L2, L3, PE: terminals - input CP-T range Ordering details Description 2CDC 271 043 S0009 The CP-T range of three-phase power supply units is the youngest member of ABB‘s power supply family. In terms of design and functionality, the new range perfectly supplements the existing products and extends the range appropriately. The devices can be supplied with a threephase voltage as well as with two-phase mains. Here, ABB offers power supply units with 24 V DC and 48 V DC outputs with 5 A, 10 A, 20 A and 40 A and efficiency of up to 92 %. As in the case of all products, they are designed for an ambient temperature of up to 70 °C. All products can be supplied within an AC supply voltage range between 340 to 575 V AC and a DC supply voltage range between 480 to 820 V DC. Ordering details Input voltage range Rated output voltage / current Type 340-575 V AC / 480-820 V DC 24 V DC / 5 A CP-T 24/5.0 1SVR427054R0000 0.80 (1.77) 340-575 V AC / 480-820 V DC 24 V DC / 10 A CP-T 24/10.0 1SVR427055R0000 1.05 (2.31) 340-575 V AC / 480-820 V DC 24 V DC / 20 A CP-T 24/20.0 1SVR427056R0000 1.75 (3.86) 340-575 V AC / 480-820 V DC 24 V DC / 40 A CP-T 24/40.0 1SVR427057R0000 3.20 (7.05) 340-575 V AC / 480-820 V DC 48 V DC / 5 A CP-T 48/5.0 1SVR427054R2000 1.05 (2.31) 340-575 V AC / 480-820 V DC 48 V DC / 10 A CP-T 48/10.0 1SVR427055R2000 1.75 (3.86) 340-575 V AC / 480-820 V DC 48 V DC / 20 A CP-T 48/20.0 1SVR427056R2000 3.40 (7.50) 2CDC 271 045 S0009 CP-T 24/5.0 Price 1 pce Weight (1 pce) kg (lb) 2CDC 271 047 S0009 CP-T 24/10.0, CP-T 48/5.0 Order code CP-T 24/20.0, CP-T 48/10.0 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/34 3 CP-T range Technical data Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated Type CP-T 24/5.0 Input circuit Rated input voltage U in 3 x 400-500 V AC Input voltage range 340-575 V AC CP-T 24/10.0 CP-T 24/20.0 CP-T 24/40.0 L1, L2, L3 480-820 V DC 3 Frequency range AC 47-63 Hz Typical input current 0.36 A 0.65 A 1.1 A 1.72 A Typical power consumption 135 W 270 W 538 W 1058 W Inrush current limiting 10 A 20 A Power failure buffering time min. 20 ms Internal input fuse 30 A min. 15 ms per phase 2 A / 600 V AC Recommended backup fuse T 3.15 A / 500 V AC T 5 A / 500 V AC 3 pole miniature circuit breaker ABB Type S203 Power factor correction (PFC) Yes, passive Discharge current towards PE < 3.5 mA input / output < 0.25 mA Indication of operational states Output voltage OUTPUT OK: green LED output voltage OK OUTPUT LOW: red LED output voltage too low Output circuit Rated output voltage 24 V DC L+, L+, L-, L- Tolerance of the output voltage 0...+1 % Adjustment range of the output voltage 22.5-28.5 V DC Rated output power 120 W Ta ≤ 60 °C 5 A 60 °C < Ta ≤ 70 °C 2.5 %/°C Rated output current I r Derating of the output current Signalling contact for output voltage OK 240 W 480 W 960 W 10 A 20 A 40 A 3.5 %/°C 13-14 solid state (max. 60 V DC, 0.3 A) Threshold 17.6-19.4 V Insulation voltage 500 V DC Mininum fuse rating to achieve short-circuit protection Maximum deviation with 13-14 M 60 V DC, m 0.3 A fast-acting load change statical ±1 % ±1 % (single mode) - Control time Starting time after applying the supply voltage Rise time ±5 % (parallel mode) change of output voltage ± 0.5 % within the input voltage range at nominal load < 2 ms at I r max. 1 s with 3500 µF max. 1.5 s at nominal load max. 150 ms with 3500 µF max. 500 ms Fall time Residual ripple and switching peaks max. 150 ms BW = 20 MHz 100 mV 80 mV Parallel connection not supported configurable, to increase power, up to increase power, to 2 devices, min. 0.1 I r - max 0.9 I r) up to 2 devices, min. 0.1 I r - max. 0.9 I r use active current balancing Series connection not supported yes, to increase voltage, max. 2 devices Resistance to reverse feed approx. 35 V Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output combined U/I characteristic curve and hiccup mode U/I- or Hiccuphiccup / fold mode adjustable back behavior Short-circuit protection continuous short-circuit proof Short-circuit behaviour current limiting Overload protection hiccup mode No-load protection continuous no-load stability Overtemperature protection yes, automatic recovery after temperature went down Starting of capacitive loads 3500 µF 3/35 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 7000 µF 7000 µF 7000 µF CP-T range Technical data Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated Type CP-T 24/5.0 General data Efficiency Duty time Dimensions (W x H x D) typ. 89 % 100% 74.3 x 124 x 118.8 mm (2.92 x 4.88 x 4.68 in) Weight Material of housing Mounting Mounting position Minimum distance to other units horizontal / vertical Degree of protection housing / terminals Protection class Electrical connection - input circuit / output circuit / signalling circuit Wire size fine-strand with wire end ferrule CP-T 24/10.0 CP-T 24/20.0 typ. 90 % 89 x 124 x 118.8 mm (3.5 x 4.88 x 4.68 in) CP-T 24/40.0 typ. 92 % 150 x 124 x 118.8 mm (5.91 x 4.88 x 4.68 in) 275.8 x 124 x 118.8 mm (10.86 x 4.88 x 4.68 in) 0.78 kg (1.72 lb) 1.045 kg (2.30 lb) 1.657 kg (3.653 lb) 3.275 kg (7.220 lb) Metal DIN rail (IEC EN 60715), snap-on mounting without any tool horizontal 25 mm / 25 mm (0.98 in / 0.98 in) IP20 / IP20 I 0.2-4 mm² (24-11 AWG) fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG) rigid 0.2-6 mm² (24-10 AWG) Stripping length Tightening torque Environmental data Ambient temperature range 8 mm (0.31 in) input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in) 1 Nm (9 lb.in) / 1.8 Nm (15.6 lb.in) operation -40...+70 °C -30…+70 °C -40...+70 °C rated load -40...+60 °C -30…+60 °C -40...+60 °C storage -40…+85 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 2 g, 10-500 Hz, 2G, each along X, Y, Z axes 60 min / cycle Shock (half-sine) (IEC/EN 60068-2-27) 15 g, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage U i input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC signalling output / PE 0.5 kV DC Pollution degree 2 Standards Product standard EN 61204-3 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC RoHS directive 2011/65/EC Electrical safety EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1 Protective low voltage SELV Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, electromagnetic field electrical fast transient/burst IEC/EN 61000-4-3 Level 3 (10 V/m) IEC/EN 61000-4-4 Level 4 (4 kV / 2.5 kHz) Level 4 (4 kV / 5 kHz) surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV) conducted disturbances, induced by radiofrequency fields power frequency magnetic fields IEC/EN 61000-4-6 Level 3 (10 V) voltage dips, short interruptions and voltage variations Interference emission IEC/EN 61000-4-8 Level 4 (30 A/m) IEC/EN 61000-4-11 dips: >95 % 0.5 ms / >30 % 0.5 ms, interruptions: >95 % 250 ms IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B limits for harmonic current emissions IEC/EN 61000-3-2 Class A „Approvals and marks“ on page 3/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/36 3 CP-T range Technical data Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated Type CP-T 48/5.0 Input circuit Rated input voltage U in 3 x 400-500 V AC Input voltage range 340-575 V AC CP-T 48/10.0 CP-T 48/20.0 L1, L2, L3 480-820 V DC 3 Frequency range AC 47-63 Hz Typical input current 0.65 A 1.1 A 1.72 A Typical power consumption 264 W 535 W 1050 W Inrush current limiting 20 A Power failure buffering time min. 20 ms Internal input fuse per phase 2 A / 600 V AC Power factor correction (PFC) 30 A min. 15 ms T3.15 A / 500 V AC T 5 A / 500 V AC yes, passive Discharge current towards PE < 3.5 mA input / output < 0.25 mA Indication of operational states Output voltage OUTPUT OK: green LED OUTPUT LOW: red LED output voltage OK output voltage too low Output circuit Rated output voltage 48 V DC L+, L+, L-, L- Tolerance of the output voltage 0...+1 % Adjustment range of the output voltage 47-56 V DC Rated output power 240 W Rated output current I r Ta 60 °C 5 A 60 °C < Ta 70 °C 2.5 %/°C load change statical ±1 % (single mode) Derating of the output current Maximum deviation with 480 W 960 W 10 A 20 A 3.5 %/°C ± 5 % (parallel mode) change of output voltage within the ±0.5 % input voltage range Control time at rated load < 2 ms Starting time after applying the supply voltage at I r max. 1 s with 7000 µF max. 1.5 s Rise time at rated load max. 150 ms with 7000 µF max. 500 ms Fall time Residual ripple and switching peaks max. 150 ms BW = 20 MHz 100 mV 80 mV Parallel connection configurable, to increase power, up to 2 devices, min. 0.1 I r - max 0.9 I r) Series connection yes, to increase voltage, max. 2 devices Resistance to reverse feed approx. 35 V approx. 63 V approx. 63 V combined U/I and hiccup mode U/I or hiccup mode, configurable hiccup mode / fold back behavior Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output to increase power, up to 2 devices, min. 0.1 I r - max. 0.9 I r use active current balancing Short-circuit protection continuous short-circuit proof Short-circuit behaviour current limiting Overload protection hiccup mode No-load protection continuous no-load stability Over temperature protection yes, automatic recovery after temperature went down Starting of capacitive loads 7000 µF 3/37 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-T range Technical data Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated Type CP-T 48/5.0 CP-T 48/10.0 CP-T 48/20.0 General data Efficiency typ. 91 % Duty time 100% Dimensions (W x H x D) 89 x 124 x 118.8 mm (3.5 x 4.88 x 4.68 in) 150 x 124 x 118.8 mm (5.91 x 4.88 x 4.68 in) 275.8 x 124 x 118.8 mm (10.86 x 4.88 x 4.68 in) Weight 1.045 kg (2.30 lb) 1.657 kg (3.653 lb) 3.275 kg (7.22 lb) Material of housing Metal Mounting DIN rail (IEC EN 60715), snap-on mounting without any tool Mounting position horizontal typ. 93 % Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection - input circuit / output circuit Wire size fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG) 0.2-4 mm² (24-11 AWG) / 0.5-10 mm² (20-8 AWG) fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG) rigid Stripping length Tightening torque Environmental data Ambient temperature range 8 mm (0.31 in) input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in) 1 Nm (9 lb.in) / 1.8 Nm (15.6 lb.in) operation -40…+70 °C -30…+70 °C -40…+70 °C rated load -40…+60 °C -30…+60 °C -40…+60 °C storage -40…+85 °C -40…+85 °C -40…+85 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2G, each along X, Y, Z axes 6 min / cycle Shock (half-sine) (IEC/EN 60068-2-27) 15G, 11 ms, 3 axes, 6 Faces, 3 times for each face Isolation data Rated insulation voltage U i input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC Pollution degree 2 Standards Product standard EN 61204-3 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC RoHS directive 2011/65/EC Electrical safety EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-16; EN 60204-1 SELV Protective low voltage Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, electromagnetic field electrical fast transient/burst IEC/EN 61000-4-3 Level 3 (10 V/m) IEC/EN 61000-4-4 Level 4 (4 kV / 5 kHz) surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV) conducted disturbances, induced by radiofrequency fields power frequency magnetic fields IEC/EN 61000-4-6 Level 3 (10 V) voltage dips, short interruptions and voltage variations Interference emission IEC/EN 61000-4-8 Level 4 (30 A/m) IEC/EN 61000-4-11 dips: >95 % 0.5 ms / >30 % 0.5 ms interruptions: >95 % 250 ms IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B limits for harmonic current emissions IEC/EN 61000-3-2 Class A „Approvals and marks“ on page 3/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/38 3 CP-T range Technical diagrams, Dimensional drawings Technical diagrams, dimensions in mm Output curve at Ta = 25 °C Uout [V] 28 28 @ 3 x 400V supply 24 16 8 4 Hiccup mode 1 2 3 4 5 6 7 8 2CDC 272 033 F0x09 20 16 2CDC 272 032 F0x09 20 16 12 12 8 4 Hiccup mode Iout [A] 2 CP-T 24/5.0 4 6 8 10 12 14 @ 3 x 400V supply 24 @ 3 x 500V supply 20 @ 3 x 500V supply 12 8 4 16 Iout [A] 4 CP-T 24/10.0 8 12 16 20 24 28 32 Iout [A] CP-T 24/20.0 U/I curve Uout [V] Uout [V] U out in V 28 20 2CDC 272 035 F0x09 8 4 Hiccup mode 4 8 12 16 20 24 28 16 Hiccup mode after 2-5 s overload 12 8 4 32 Iout [A] 8 CP-T 24/20.0 Hiccup mode 16 24 32 40 56 48 64 72 80 32 24 16 8 Hiccup mode 1 Iout in A CP-T 24/40.0 Uout [V] @ 3 x 500V supply 40 U/I 20 12 @ 3 x 400V supply 48 24 2CDC 272 037 F0x09 @ 3 x 500V supply 16 56 @ 3 x 400 V supply @ 3 x 400V supply 24 2CDC 272 027 F0211 28 2 3 4 5 6 7 8 Iout [A] CP-T 48/5.0 Uout [V] U out in V 56 @ 3 x 400V supply 48 @ 3 x 400V supply 48 @ 3 x 500V supply @ 3 x 400 V supply 56 @ 3 x 500V supply 32 40 24 16 8 2 4 6 8 10 12 14 16 8 Hiccup mode 2 16 Iout [A] CP-T 48/10.0 U/I curve 4 6 8 10 12 14 16 Iout [A] CP-T 48/10.0 Hiccup mode U/I 32 Hiccup mode after 2-5 s overload 24 16 8 4 8 12 16 20 24 28 32 36 40 Iout in A CP-T 48/20.0 dimensions in mm 2CDC 272 021 F0009 Dimensional drawings 24 2CDC 272 039 F0x09 40 32 2CDC 272 038 F0x09 40 48 2CDC 272 028 F0211 56 CP-T 24/5.0 118.8 4.68‘‘ 111.9 4.41‘‘ CP-T 24/20.0, CP-T 48/10.0 3/39 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-T 24/40.0, CP-T 48/20.0 2CDC 272 024 F0009 131 5.16‘‘ 275.8 10.86‘‘ 124 4.88‘‘ 131 5,16‘‘ CP-T 24/10.0, CP-T 48/5.0 124 4,88‘‘ 2CDC 272 022 F0009 131 5,16‘‘ 150 5,91‘‘ 111,9 4,41‘‘ 2CDC 272 023 F0009 118,8 4,68‘‘ 89 3,5‘‘ 124 4,88‘‘ 3 28 @ 3 x 400V supply @ 3 x 500V supply 24 Uout [V] 2CDC 272 034 F0x09 Uout [V] CP-T range Technical diagrams Temperature curve at rated load Pout [%] -40 2CDC 272 026 F0211 100 90 80 70 60 50 40 30 20 10 60 70 100 90 80 70 60 50 40 30 20 10 -30 Ta [°C] 3 2CDC 272 030 F0211 Pout [%] 60 70 Ta [°C] CP-T 24/20.0, CP-T 48/10.0 CP-T 24/40.0, CP-T 48/20.0 Pout [%] -40 2CDC 272 025 F0211 100 90 80 70 60 50 40 30 20 10 60 70 Ta [°C] CP-T 24/5.0, CP-T 24/10.0, CP-T 48/5.0 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/40 CP-S and CP-C Product group picture 3 3/41 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-S and CP-C Table of contents CP-S and CP-C range Product group picture 3/41 Table of contents 3/42 Benefits and advantages 3/43 Operating control 3/44 Ordering details 3/45 Technical data 3/46 Technical diagrams, Dimensional drawings 3/50 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/42 3 CP-S and CP-C Benefits and advantages Benefits 1 Integrated power reserve The new CP-S and CP-C range power supplies feature an integrated power reserve of up to 50 %. No oversized electricity supply is needed, especially under heavy load conditions. 2 Pluggable connecting terminals Extended flexibility in operation due to pluggable connecting terminals (this feature is not offered on all devices). CP-S range –– 10 A and 20 A device with front-face selector switch to adjust r ated input voltage range: 110-120 V AC or 220-240 V AC –– Output voltage fixed at 24 V DC –– Parallel operation for redundancy 3 Adjustable output voltage The CP-C range types feature a continuously adjustable output voltage from 22 to 28 V. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by long line length. CP-C range –– Wide range input 110-240 V AC (85-264 V AC, 100-350 V DC) –– Output voltage adjustable within a range of 22-28 V DC –– Parallel operation for increased capacity and redundancy –– Power factor correction (PFC) acc. to EN 61000-3-2 –– Function module pluggable onto the front side Pluggable function modules 4 The CP-C range power supplies can be equipped with pluggable modules to add additional functions (e.g. messaging module). Thus, the power supplies can be ideally adapted to the relevant application. 3/43 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 3 4 2CDC 273 058 F0004 2 2CDC 273 046 F0004 1 2CDC 273 057 F0004 Messaging module CP-C MM: –– LED for status indication –– Relay outputs "Input OK" and "Output OK" –– REMOTE ON/OFF function to switch on and off the power supply externally –– Output voltage monitoring is only possible in decoupled parallel operation 2CDC 273 056 F0004 3 Characteristics CP-S and CP-C range –– Output current 5 A, 10 A and 20 A –– Integrated power reserve of up to 50 % –– 5 A and 10 A devices with pluggable connecting terminals –– Approvals / marks (depending on device, partly pending) –– A, H, R , K, / a, b CP-S and CP-C Operating control 1 OUTPUT L+, L‑: terminals ‑ output 2 Indication of operational states 1 OUTPUT OK: green LED ‑ output voltage OK 3 OUTPUT Adj.: rotary potentiometer ‑ adjustment of output voltage 4 Circuit diagram 2 5 INPUT L, N, PE: terminals ‑ input 3 4 5 1 1 OUTPUT L+, L‑: terminals ‑ output 2 Indication of operational states OUTPUT OK: green LED ‑ output voltage OK 3 Circuit diagram 2 4 INPUT L, N, PE: terminals ‑ input 3 4 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/44 3 CP-S and CP-C Ordering details Description The power supply units in the CP-S and CP-C range are ABB’s high-end solutions. Designed with an integrated 50 % power reserve and an efficiency of approximately 89 % these are the perfect products for all complex, highly reliable applications. All the devices cover the U-I output characteristic and are built with thermal protection which switches off in case of overheating. In particular, the devices of the CP-C range feature a much broader functionality, including active power factor correction and pluggable function modules. These products are designed to trip MCB‘s in the 24 V DC output circuit. Coordination tables are available. 2CDC 271 061 F0004 3 Ordering details - CP-S Input voltage range Rated output voltage / current Type Order code 85-264 V AC / 110-350 V DC 24 V DC / 5 A CP-S 24/5.0 1SVR427014R0000 0.96 (2.11) 85-132 V AC, 184-264 V AC / 220-350 V DC 24 V DC / 10 A CP-S 24/10.0 1SVR427015R0100 1.07 (2.35) 85-132 V AC, 184-264 V AC / 220-350 V DC 24 V DC / 20 A CP-S 24/20.0 1SVR427016R0100 2.83 (6.23) Rated output voltage / current Type Order code 85-264 V AC / 110-350 V DC 24 V DC / 5 A CP-C 24/5.0 1SVR427024R0000 0.96 (2.11) 85-264 V AC / 110-350 V DC 24 V DC / 10 A CP-C 24/10.0 1SVR427025R0000 1.34 (2.95) 85-264 V AC / 110-350 V DC 24 V DC / 20 A CP-C 24/20.0 1SVR427026R0000 3.15 (6.94) Type Order code 1 pce CP-S 24/5.0 2CDC 271 063 F0004 Price Weight (1 pce) kg (lb) CP-S 24/20.0 Ordering details - CP-C 2CDC 271 065 F0004 Input voltage range Price 1 pce Weight (1 pce) kg (lb) CP-C 24/10.0 Description Price 1 pce Messaging module for CP-C range power supplies 3/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-C MM 1SVR427081R0000 Weight (1 pce) kg (lb) 0.065 (0.14) CP-S and CP-C Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type Input circuit - supply circuit Rated input voltage U in CP-S CP-S Typ. power consumption Inrush current limiting / I 2 t ( cold start) CP-C switch position 115 switch position 230 CP-C switch position 115 switch position 230 CP-S and CP-C at 110-240 V AC CP-S at 110-120 V AC CP-S at 220-240 V AC CP-C CP-S Power failure buffering time Transient overvoltage protection Internal input fuse (apparatus protection, not accessible) Power factor correction (PFC) Indication of operational states Output voltage Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Peak output current (power reserve) Derating Deviation with Control time Starting time after applying supply voltage Rise time 10-90 % Residual ripple and switching peaks Parallel connection CP-C 24/10.0 CP-C 24/20.0 CP-S 24/5.0 CP-S 24/10.0 CP-S 24/20.0 L, N Input voltage range Frequency range AC Typical input current CP-C 24/5.0 CP-C CP-S 110-240 V AC 110-240 V AC 110-120 V AC 220-240 V AC 85-264 V AC / 100-350 V DC 1) 85-264 V AC / 10085-132 V AC 350 V DC 1) 184-264 V AC / 220-350 V DC 1) 47-63 Hz 2.2-1.2 A 2.6-1.2 A 5.5-2.5 A 4.2-4.0 A 9.0-8.0 A 2.4-2.2 A 4.5-4.0 A 135 W 269 W 538 W < 23 A / approx. < 33 A / approx. 0.2 A 2s < 40 A / approx. 1.9 A 2s 0.9 A 2s < 40 A / approx. 1.8 A 2s < 70 A / approx. 8 A 2s min. 100 ms min. 40 ms min. 40 ms varistors 4 A (slow-acting) 6.3 A (slow-acting) 12 A (fast-acting) yes, active no OUTPUT OK: green LED V : output voltage OK L+, L+, L-, L- : short-circuit, no-load and overload proof 24 V DC CP-C ±1 % CP-S -1...+5 % CP-C 22-28 V DC, default setting 24 V ±0.5 % CP-S fixed 120 W 240 W 480 W 10 A 20 A Ta m 60 °C 5 A Ta m 40 °C typ. 7.25 A typ. 12.25 A typ. 22.5 A 60 °C < Ta m 70 °C 2.5 % per Kelvin temperature increase CP-C load change statical 10-90 % typ. < ±0.05 % CP-S load change statical 10-90 % typ. < ±0.1 % load change dynamical 10-90 % typ. < ±3 % change of the input voltage of ±10 % typ. < ±0.05 % typ. < 1 ms CP-C < 200 ms < 200 ms typ. < 200 ms CP-S < 250 ms typ. < 300 ms CP-C typ. < 30 ms typ. < 4 ms typ. < 12 ms CP-S typ. < 5 ms typ. < 15 ms BW = 20 MHz typ. < 50 mV PP yes, up to 5 devices, to enable redundancy and to increase power, current not symmetrical (CP-S only redundancy) Series connection Resistance to reverse feed yes, to increase voltage, for decoupling refer to the application manual approx. 35 V DC Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output Current limiting at short circuit Short-circuit protection Overload protection Starting of capacitive loads General data Power dissipation Efficiency Discharge current for PE MTBF see also U/I- and I/T-characteristic curves U/I characteristic curve with power reserve approx. 11 A approx. 19 A approx. 25 A continuous short-circuit stability thermal protection unlimited Dimensions (W x H x D) Weight Minimum distance to other units Degree of protection Material of housing Protection class (EN 61140) Mounting Mounting position typ. < 15 W typ. < 29 W typ. 89 % < 3.5 mA CP-C 500.000 h CP-S 350.000 h 56.5 (60 2)) x 130 x 135.5 90 (93.5 2)) x 130 x 135.5 mm (2.22 (2.36 2)) x 5.12 x mm (3.54 (3.68 2)) x 5.12 x 5.35 in) 5.35 in) CP-C approx. 0.96 kg (2.12 lb) approx. 1.34 kg (2.95 lb) CP-S approx. 1.07 kg (2.36 lb) horizontal / vertical 10 mm / 80 mm (0.39 in / 3.15 in) housing / terminals IP20 / IP20 housing shell / cover aluminium / zinc-coated sheet steel I DIN rail (IEC/EN 60715), snap-on mounting horizontal typ. < 58 W 200 (203.5 2)) x 130 x 135.5 mm (7.87 (8.01 2)) x 5.12 x 5.35 in) approx. 3.15 kg (6.94 lb) approx. 2.83 kg (6.23 lb) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/46 3 CP-S and CP-C Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type Electrical connection - Input circuit Wire size 3 Stripping length Tightening torque Electrical connection - Output circuit Wire size Stripping length Tightening torque Environmental data Ambient temperature range Pollution degree (IEC/EN 60950-1; EN 50178) Overvoltage category (IEC/EN 60950-1; EN 50178) Standards Product standard Low Voltage Directive EMC Directive Electrical safety Protective low voltage Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient / burst surge conducted disturbances, induced by radiofrequency fields 3) CP-S 24/20.0 3) 3) 3) 3) - 2.5-10 mm 2 (14-8 AWG) 0.5-10 mm 2 (20-8 AWG) 0.5-16 mm 2 (20-6 AWG) 12 mm (0.47 in) 1.2-1.5 Nm 2.5-10 mm 2 (14-8 AWG) 0.5-10 mm 2 (20-8 AWG) 0.5-16 mm 2 (20-6 AWG) 12 mm (0,47 in) 1.2-1.5 Nm operation -25...+70 °C rated load 0...+60 °C (without derating) storage -40...+85 °C 93 % at +40 °C, no condensation 3K3 Power-frequency withstand voltage test (test voltage) (routine test / type test) 2) CP-C 24/20.0 CP-S 24/10.0 fine-strand with wire end ferrule 0.12-2.5 mm 2 (26-14 AWG) fine-strand without wire end ferrule rigid 8 mm (0.31 in) 0.4 Nm Rated impulse withstand voltage U imp between all isolated circuits (IEC/EN 60950-1; EN 50178) 1) CP-C 24/10.0 CP-S 24/5.0 fine-strand with wire end ferrule 0.2-2.5 mm 2 (24-14 AWG) fine-strand without wire end ferrule rigid 7 mm (0.28 in) 0.4 Nm Damp heat (IEC/EN 60068-2-3) Climatic category (IEC/EN 60721) Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) Isolation data Rated insulation voltage U i between all isolated circuits (IEC/EN 60950-1; EN 50178) Interference emission high-frequency radiated high-frequency conducted CP-C 24/5.0 input / output input / PE output / PE input / output input / PE output / PE input / output input / PE output / PE 300 V 300 V 50 V 4 kV; 1.2/50 µs 2.5 kV; 1.2/50 µs 500 V; 1.2/50 µs 1.5 kV AC / 3.0 kV AC 1.5 kV AC / 3.0 kV AC 500 V DC / 500 V DC 2 II IEC/EN 61204 2006/95/EC 2004/108/EC EN 50178, EN 60950, UL 60950, UL 508 SELV (EN 60950) IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-6-2 Level 4 (8 kV / 15 kV) Level 3 (10 V/m) Level 4 (4 kV) Level 4 (2 kV symmetrical, level 3 - 3 kV asymmetrical) Level 3 (10 V) IEC/EN 61000-6-3 IEC/CISPR 22; EN 55022 Class B IEC/CISPR 22; EN 55022 Class B at U > 264 V use additionally an appropriate external fuse with lateral screw pluggable connecting terminals, actuate only when power is off „Approvals and marks“ on page 3/4. 3/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-S and CP-C Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type Input circuit - Supply circuit Rated input voltage U in Input voltage range Power consumption Input circuit - Control circuit Kind of triggering Control input, control function Threshold "Switching-off power supply unit" Threshold "Switching-on power supply unit" Input current Maximum cable length to the control input Measuring circuit - INPUT CP-C MM 110-240 V AC / 100-350 V DC 70-264 V AC / 80-350 V DC 2.5 VA / 1.5 W volt-free triggering Remote OFF remote off R 1 k R 10 k typ. 1 mA (200 mA for 200 µs) 25 m - 100 pF/m powered by the input circuit of the power supply unit Monitoring function undervoltage monitoring of input voltage of the power supply unit 85 V AC / 90 V DC AC: typ. -8 % / DC -30 % -5 % at AC and DC typ. < 50 ms powered by the output circuit of the power supply unit undervoltage monitoring of output voltage of the power supply unit 20 V DC typ. 5 % ±1 % typ. < 10 ms Thresholds Hysteresis, related to the threshold value Accuracy, tolerance Maximum measuring cycle Measuring circuit - OUTPUT Monitoring function Thresholds Hysteresis, related to the threshold value Accuracy, tolerance Maximum measuring cycle Indication of operational states Remote off Status of power supply input Status of power supply output REMOTE OFF: green LED V : „REMOTE OFF“ input R 1k Input OK: green LED V : relay „INPUT OK“ energized OUTPUT OK: green LED V : relay „OUTPUT OK“ energized Output circuits Kind of output Operating principle Contact material Rated voltage (VDE 0110, IEC/EN 60947-1) Minimum switching voltage / Minimum switching current Maximum switching voltage / Maximum switching current Rated operating current I e (IEC/EN 60947-1) AC-12 (resistive) at 230 V AC-15 (inductive) at 230 V DC-12 (resistive) at 24 V DC-13 (inductive) at 24 V Mechanical lifetime Electrical lifetime Short circuit proof, n/c contact maximum fuse rating n/o contact General data Duty time Dimensions (W x H x D, when mounted) Weight Degree of protection housing / terminals Material of housing Protection class (EN 61140) Mounting Mounting position Electrical connection Wire size fine-strand with wire end ferrule fine-strand without wire end ferrule rigid Stripping length Tightening torque 11-12/14, 21-22/24 relays, 2 x 1 c/o contacts closed-circuit principle AgNi 250 V 24 V / 10 mA 250 V / 1 A 1A 1A 1A 1A 30 x 10 6 switching cycles 0.1 x 10 6 switching cycles 2 A, gL 2 A, gL 100 % 56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 in) 0.065 kg (0.14 lb) IP20 / IP20 Plastic II snap-on mounting, without any tool plugged onto the power supply unit 0.2-2.5 mm 2 (24-14 AWG) 0.2-4 mm 2 (24-12 AWG) 7.5 mm (0.3 inch) 0.4-0.6 Nm 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/48 3 CP-S and CP-C Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type Environmental data Ambient temperature range 3 CP-C MM operation -25...+70 °C storage -40...+85 °C 93 % at +40 °C, no condensation 3K3 Damp heat (IEC/EN 60068-2-3) Climatic category (IEC/EN 60721) Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) Isolation data Rated insulation voltage U i (IEC/EN 60974-1, EN 50178, VDE 0160) Protective separation (EN 50178, EN 60950) supply / measuring circuits / relay outputs Rated impulse withstand voltage U imp between all isolated circuits (IEC 664, VDE 0110) Test voltage between all circuits (type test) Pollution degree (EN 60950) Overvoltage category (EN 60950) Standards Product standard Low Voltage Directive EMC Directive Electrical safety Elektromagnetic compatibility Interference immunity to electrostatic discharge IEC/EN 61000-4-2 radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 electrical fast transient / burst IEC/EN 61000-4-4 surge IEC/EN 61000-4-5 conducted disturbances, induced by radio-frequency fields Interference emission high-frequency radiated high-frequency conducted IEC/EN 61000-4-6 250 V yes 4 kV; 1.2/50 µs 2.5 kV AC 2 II IEC/EN 61204 2006/95/EC 2004/108/EC EN 50178, EN 60950, UL 60950, UL 508 IEC/EN 61000-6-2 Level 3 and 4 (6 kV / 8 kV) Level 3 (10 V/m) Level 4 and 2 (4 kV power input / 1 kV control input) Level 3 and 2 (4 kV symmetrical power input / 1 kV control input) Level (10 V) IEC/EN 61000-6-3 IEC/CISPR 22; EN 55022 Class B IEC/CISPR 22; EN 55022 Class B „Approvals and marks“ on page 3/4. 3/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-S and CP-C Technical diagrams, Dimensional drawings Technical diagrams Temperature curve at Uout = 24 V DC Uout [V] Iout [A] Uout [V] Iout [A] Iout [A] Iout [A] CP-C 24/10.0 CP-S 24/10.0 Uout [V] 2CDC 272 027 F0b04 Uout [V] 2CDC 272 004 F0b04 CP-S 24/5.0, CP-C 24/5.0 CP-S 24/10.0, CP-C 24/10.0 Iout [A] 2CDC 272 028 F0b04 2CDC 272 005 F0b04 Iout [A] CP-C 24/20.0 CP-S 24/20.0, CP-C 24/20.0 Ta [°C] dimensions in mm 60,0 [2.36”] 93,5 [3.68”] 203,5 [8.01”] 56,5 [2.22”] 90,0 [3.54”] 200,0 [7.87”] 135,5 [5.33”] 130,0 [5.12”] 130,0 [5.12”] CP-S 24/10.0 CP-C 24/10.0 CP-S 24/20.0 CP-C 24/20.0 56,5 [2.22”] 24 ] 4” .9 [0 2CDC 272 016 F0b07 54 [2.13”] CP-S 24/5.0 CP-C 24/5.0 CP-A RU 2CDC 272 015 F0b07 144,5 [5.69”] 137,0 [5.39”] 130,0 [5.12”] Dimensional drawings Ta [°C] Iout [A] Uout [V] CP-S 24/20.0 3 2CDC 272 006 F0204 Ta [°C] CP-C 24/5.0 2CDC 272 075 F0204 Iout [A] CP-S 24/5.0 2CDC 272 088 F0204 Iout [A] 2CDC 272 026 F0b04 Output curve at 25 °C Uout [V] 2CDC 272 003 F0b04 Output curve at 25 °C CP-C MM 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/50 Redundancy units Ordering details Ordering details 2CDC 271 003 F0005 Description 3 CP-A RU + CP-A CM suitable for decoupling of Type two CP-24 V DC power supply units or suitable for decoupling of CP-E power supply units Order code Price 1 pce Weight (1 pce) kg (lb) 2 inputs each up to 20 A and 1 output up to 40 A 40 V and M 5 A CP-A RU 1SVR427071R0000 0.89 (1.96) Control module for CP-A RU redundancy units - CP-A CM 1SVR427075R0000 0.063 (0.14) 2 inputs each up to 2.5 A and 1 output up to 5 A 35 V and < 5 A CP-RUD 1SVR423418R9000 0.15 (0.33) 2CDC 271 010 F0006 Ordering details - CP-D RU for decoupling of two CP‑D power supply units Input voltage range Rated input current Rated output voltage / Type current 9-35 V DC 2x5A 24 V DC / 1 x 10 A 2CDC 271 006 F0003 CP-A RU 2CDC 271 010 F0006 CP-RUD CP-D RU 3/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-D RU Order code 1SVR427049R0000 Price Weight (1 pce) kg (lb) 0.075 (0.165) Redundancy units Technical data Type Input circuit - Supply circuit Rated input voltage U in Input voltage range per channel Rated input current Iin per channel Maximum input current per channel Transient overvoltage protection Output circuit Rated output voltage U out Voltage drop Rated output current I out Output ratings per channel CP-A RU 2) in combination with CP-A CM (+/ -, +/ -) 24 V DC 10-28 V DC 1-20 A 30 A for 300 s yes 13-28 V DC (++/--) 24 V DC typ. 0.6 V, max. 0.9 V 1-40 A Ta = 60 °C 10-28 V DC / 40 A 13-28 V DC / 40 A Ta = 70 °C 10-28 V DC / 30 A 13-28 V DC / 30 A 60 °C < Ta m 70 °C 2.5 % per Kelvin temperature increase 60 A for 300 s < 40 V Derating Peak output current Resistance to reverse feed General data Dimensions (W x H x D) Weight Minimum distance to other units horizontal / vertical Degree of protection housing / terminals Material of housing housing shell / cover Protection class Mounting Mounting position Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule fine-strand without wire end ferrule rigid Stripping length Tightening torque Environmental data Ambient temperature range operation rated load storage Damp heat (IEC/EN 60068-2-3) Climatic category (IEC/EN 60721) Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) Isolation data Insulation voltage between input / output / housing Pollution degree (EN 50178) Standards Product standard Low Voltage Directive EMC Directive Electrical safety Electromagnetic compatibility Interference immunity to electrostatic discharge IEC/EN 61000-4-2 radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 electrical fast transient / burst IEC/EN 61000-4-4 surge IEC/EN 61000-4-5 conducted disturbances, induced by radioIEC/EN 61000-4-6 frequency fields Interference emission high-frequency radiated IEC/CISPR 22 / EN 55022 high-frequency conducted IEC/CISPR 22 / EN 55022 1) CP-A RU 56.5 (60 1)) x 130 x 135.5 mm; (2.22 (2.36 1)) x 5.12 x 5.35 in) 0.89 kg (1.96 lb) 10 mm / 50 mm (0.39 in / 1.97 in) IP20 / IP20 aluminium / zinc-coated sheet steel III 2) DIN rail (IEC/EN 60715) horizontal 2.5-10 mm 2 (14-8 AWG) 0.5-10 mm 2 (20-8 AWG) 0.5-16 mm 2 (20-6 AWG) 12 mm (0.47 in) 1.2-1.5 Nm -25...+70 °C -25...+60 °C (without derating) -40...+85 °C 93 % at 40 °C, no condensation 3K3 500 V AC (routine test) 2 IEC/EN 61204 2006/95/EC 2004/108/EC EN 50178, EN 60950, UL 60950, UL 508 IEC/EN 61000-6-2 Level 3 (air discharge ±8 kV, contact discharge ±6 kV) Level 3 (10 V/m) Level 3 (±2 kV) Level 1 (±0.5 kV) Level 3 (10 V) IEC/EN 61000-6-3 Class B Class B incl. lateral screw This device is designed for connection to a safety extra-low voltage source. If no safety extra-low voltage is used at the input side, the lateral screw can be used for grounding of the housing (protection class I). „Approvals and marks“ on page 3/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/52 3 Redundancy units Technical data 3 Type Input circuit - Supply circuit Rated input voltage U in Input voltage range Rated input current at rated sense load and 24 V DC Power consumption at 24 V DC Measuring circuit Monitoring function Measuring voltage Thresholds Hysteresis, related to the threshold value Accuracy, tolerance Maximum measuring cycle Indication of operational states Status of input 1 IN 1: green LED Status of input 2 IN 2: green LED Output status OUT: green LED Output circuit Kind of output Contact material Operating principle Rated operational voltage U e (IEC/EN 60947-1, VDE 0110) Minimum switching voltage / Minimum switching current Maximum switching voltage / Maximum switching current Rated operational current I e AC-12 (resistive) at 230 V (IEC/EN 60947-5-1) AC-15 (inductive) at 230 V DC-12 (resistive) at 24 V DC-13 (inductive) at 24 V Mechanical lifetime Electrical lifetime Rating according UL 508 General purpose (GP) 250 V AC Maximum fuse rating to achieve n/o contact short-circuit protection n/c contact Sense output (+, +, -) Sense output voltage Sense output current Maximum fuse rating General data Duty time Dimensions (W x H x D, when mounted) Material of housing Weight Degree of protection Protection class Mounting Mounting position Electrical conection Wire size CP-A CM 24 V DC 13-28 V DC 120 mA approx. 1 W 11-12/14, 21-22/24 undervoltage monitoring rated operational voltage 14-28 V fix: 3-5 % 10 % of full-scale value 6 ms : voltage at input 1 > than threshold 1 = no faults present : voltage at input 2 > than threshold 2 = no faults present : U OUT > 3 V = no faults present +, +, relays, 2 x 1 c/o contact AgNi closed-circuit principle 250 V 24 V / 10 mA 250 V / 1 A 1A 1A 1A 1A 30 x 10 6 switching cycles 0.1 x 10 6 switching cycles 1A 2 A, gL 2 A, gL 1 SVR 427 075 R0000 13-28 V DC 0.1 A For applications acc. UL the sense output shall be provided with a listed DC fuse 3 A 100 % 56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 in) plastic 0.063 kg (0.14 lb) housing / terminals IP20 / IP20 II snap-on mounting, without any tool plugged onto the redundancy unit CP-A RU fine-strand with wire end ferrule 0.2-2.5 mm 2 (24-14 AWG) fine-strand without wire end ferrule rigid 0.2-4 mm 2 (24-12 AWG) 7.5 mm (0.3 in) 0.4-0.6 Nm Stripping length Tightening torque Isolation data Rated insulation voltage U i (IEC/EN 60947-1, EN 50178, VDE 0160) Rated impulse withstand voltage U imp (type test) between all circuits (IEC 664, VDE 0110) Power-frequency withstand voltage test (routine test) between all circuits Protective separation (EN 50178) between input and output Pollution degree Overvoltage category Environmental data Ambient temperature range operation storage Damp heat (IEC/EN 60068-2-3) Climatic category (IEC/EN 60721) Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) 3/53 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 250 V 2.5 kV 1.2 kV AC yes 2 II -25...+70 °C -40...+85 °C 93 %at 40 °C, no condensation 3K3 Redundancy units Technical data Type Input circuit - Supply circuit Rated input voltage U in CP-RUD A: U1+/-U ; B: U2+/-U 24 V DC Input voltage range 5-35 V DC Rated input current I in per channel 0.5-2.5 A Maximum input current per channel 10 A for 300 s Transient overvoltage protection no Output circuit Rated output voltage U out 24 V DC Voltage drop typ. 0.6 V, max. 0.7 V Rated output current I out 0.5-5 A Peak output current 20 A for 150 s Resistance to reverse feed < 35 V General data Dimensions (W x H x D) 22.5 x 78 x 100 mm (0.89 x 3.07 x 4.02 in) L+, L+, L+, L-, L-, L- Weight Minimum distance to other units 0.135 kg (0.30 lb) horizontal / vertical 10 mm / 10 mm (0.39 in / 0.39 in) Degree of protection housing / terminals IP20 / IP20 Material of housing housing shell / cover plastic / plastic Protection class - Mounting DIN rail (IEC/EN 60715) Mounting position horizontal Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule 2 x 0.75-2.5 mm 2 (2 x 18-14 AWG) fine-strand without wire end ferrule rigid 2 x 0.5-4 mm 2 (2 x 20-12 AWG) Stripping length 7 mm (0.28 in) Tightening torque 0.6-0.8 Nm Environmental data Ambient temperature range operation -20...+60 °C rated load -20...+60 °C storage -40...+85 °C 93 % at 40 °C, no condensation Damp heat (IEC/EN 60068-2-3) Climatic category (IEC/EN 60721) - Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) Isolation data Insulation voltage between input / output / housing - Pollution degree (EN 50178) 2 Standards Product standard Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Electrical safety EN 50178 Electromagnetic compatibility Interference immunity to electrostatic discharge IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 3 (air discharge ±8 kV, contact discharge ±6 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m) electrical fast transient/burst IEC/EN 61000-4-4 Level 3 (w2 kV) IEC/EN 61000-4-5 Level 1 (w0.5 kV) IEC/EN 61000-4-6 Level 3 (10 V) surge conducted disturbances, induced by radiofrequency fields Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22 / EN 55022 Class B high-frequency conducted IEC/CISPR 22 / EN 55022 Class B 1) 2) incl. lateral screw This device is designed for connection to a safety extra-low voltage source. If no safety extra-low voltage is used at the input side, the lateral screw can be used for grounding of the housing (protection class I). 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/54 3 Redundancy units Technical data Type 3 CP-D RU Input circuit - Supply circuit Rated input voltage U in IN 1 + + -, IN 2 + + 24 V DC Input voltage range 9-35 V DC Rated input current I in per channel 5A Maximum input current per channel 10 A for 300 s Transient overvoltage protection no Output circuit Rated output voltage U out 24 V DC Voltage drop typ. 0.5 V Rated output current I out 10 A Resistance to reverse feed < 35 V General data MTBF on request OUT + + +, - - - Duty time 100 % Dimensions (W x H x D) product dimensions 35 x 91 x 56.5 mm (1.38 x 3.58 x 2.22 in) packaging dimensions 134 x 94 x 48 mm (5.28 x 3.70 x 1.89 in) Weight net weight 0.075 kg (0.165 lb) gross weight 0.130 kg (0.286 lb) Material of housing plastic Mounting DIN rail, snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm (0.98 in) / 25 mm (0.98 in) Electrical connection - Input circuit / Output circuit Wire size fine-strand with (out)wire end ferrule 0.2-2.5 mm 2 (24-14 AWG) rigid 0.2-2.5 mm 2 (24-12 AWG) Stripping length 7.0 mm (0.28 in) Tightening torque 0.67 Nm (6 Ib.in) Environmental data Ambient temperature range operation -40...+70 °C storage -40...+85 °C Relative humidity RH at 40 °C 20-95 %, no condensation Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) Mounting by rail: 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min for each axis 15 G, 11 ms, 3 axis, 6 faces, 3 times for each face Standards Product standard IEC/EN 61204-3 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2011/65/EC Electromagnetic compatibility Interference immunity to EN 55024 electrostatic discharge IEC/EN 61000-4-2 Level 3, air discharge 8 kV, contact discharge 4 kV radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3, 10 V Interference emission EN 55022 high-frequency radiated IEC/CISPR 22 / EN 55022 Class B high-frequency conducted IEC/CISPR 22 / EN 55022 Class B 3/55 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Redundancy units Dimensional drawings 35.0 1.38” IN1 - IN2 - 67.0 2.64” + - OUT - - 57.5 2.26” 2CDC272033F0010 + 49.0 1.93” + 32.1 1.26” 91.0 3.58” 44.5 1.75” 56,5 [2.22” ] CP-D RU 24 ] 4” .9 [0 CP-A CM 144,5 [5.69”] 144,5 [5.69”] 137,0 [5.39”] 3 2CDC 272 016 F0b07 IN2 54 [2.13”] IN1 + + + + 109,5 102 [4.31“] 60,0 [2.36”] [4.02“] 56,5 [2.22”] 22,5 137,0 [5.39”] 93,5 [3.68”] [.886“] 90,0 [3.54”] 203,5 [8.01”] 60,0 [2.36”] 93,5 [3.68”] 56,5 [2.22”] 90,0 [3.54”] 200,0 [7.87”] CP-RUD 135,5 [5.33”] 130,0 [5.12”] 130,0 [5.12”] 130,0 [5.12”] 130,0 [5.12”] [3.94“] 2CDC 272 015 F0b07 100 78 [3.07“] 130,0 [5.12”] 135,5 [5.33”] 2CDC 252 188 F0b05 CP-A RU 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/56 CP-ASI range Product group picture 3 3/57 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-ASI range Table of contents CP-ASI Product group picture 3/57 Table of contents 3/58 Benefits and advantages 3/59 Ordering details 3/60 Technical data 3/61 Technical diagrams 3/63 Dimensional drawings 3/64 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/58 3 CP-ASI range Benefits and advantages 3 Characterics –– Rated output voltage 30.5 V DC for ASI-bus –– Rated output current up to 8.0 A –– High efficiency of up to 92 % 1) –– Infrared addressing mode 2) –– Low power dissipation and low heating –– Free convection cooling (no forced cooling with ventilators) –– Ambient temperature range during operation -10…70 °C 3) – – Open-circuit, overload and short-circuit stable – – Integrated input fuse – – Tool-free mounting on DIN rail as well as demounting – – LEDs for the indication of operational states – – Approval4): A /Mark: a 1) 2) 3) 4) Efficiency is depending on device Except CP-ASI/4.0 DC/DC Ambient temperature range CP-ASI/4.0 DC/DC -25…70°C Approvals are related to rated input voltage Uin 1 2 1 Output +, -, +, -, SHIELD: output terminals 2 Signalling contact 11-12: ground fault signalling terminals 3 Indication of operational states AS-I OK: green LED - output voltage OK 4 Configuration of operation mode Jumper 3 4 5 6 7 8 9 10 3/59 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 5 Indication of operational states IR ADDRESSING ON: red LED - infrared addressing mode active 6 Test and reset button 7 Indication of operational states GROUND FAULT: red LED - ground fault detected 8 Circuit diagram 9 Input voltage selector Adjustment of input voltage 10 Input L, N, PE: input terminals CP-ASI range Ordering details Description 2CDC 271 002 S0012 The CP-ASI power supply range is specifically designed with integrated data decoupling for the supply of AS-Interface systems. Up to 62 slaves (binary I/O devices) can be supplied with a single two-conductor cable. The configurable IR addressing mode allows the easy assign of new ID addresses by means of an external infrared programming unit. CP-ASI/2.8 Ordering details 2CDC 271 003 S0012 Input Voltage Range Rated Output Voltage Rated Output Current Type Order code Price 85-132 V AC, 184-264 V AC 30.5 V DC 2.8 A CP-ASI/2.8 1SVR427090R0280 0.495 (1.091) 85-132 V AC, 184-264 V AC 30.5 V DC 4.0 A CP-ASI/4.0 1SVR427090R0400 0.653 (1.440) 18-32.4 V DC 30.5 V DC 4.0 A CP-ASI/4.0 DC/DC 1SVR427095R0400 0.488 (1.076) 85-132 V AC, 184-264 V AC 30.5 V DC 8.0 A CP-ASI/8.0 1SVR427090R0800 0.897 (1.978) 1 pce Weight (1 pce) kg (lb) 2CDC 271 004 S0012 CP-ASI/4.0 DC/DC 2CDC 271 005 S0012 CP-ASI/4.0 CP-ASI/8.0 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/60 3 CP-ASI range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type Input circuit - Supply circuit Rated input voltage U in Input voltage range 3 CP-ASI/2.8 switch position 115 V 100-120 V AC switch position 230 V 220-240 V AC switch position 115 V 85-132 V AC switch position 230 V 184-264 V AC 47-63 Hz switch position 115 V 2.0 A switch position 230 V 0.9 A Allowed voltage between input and earth (ground) CP-ASI/4.0 DC/DC: Allowed input ripple voltage CP-ASI/4.0 DC/DC: Continuous input voltage with no damage to the DC/DC converter Turn-on voltage Shut-down voltage Typical power consumption 94 W Inrush current limiting / I²t (cold start) < 20 A (132 V AC) / approx. 1.5 A²/s < 38 A (264 V AC) / approx. 1.8 A²/s Discharge current towards PE Power failure buffering time at 115 V AC at 230 V AC Transient overvoltage protection Reverse input polarity protection Internal input fuse External fusing (not necessary, but recommended) Indication of operational states Output voltage IR addressing mode Overload Output circuit Rated output voltage Rated output power Tolerance of the output voltage Adjustment range of the output voltage Rated output current I r CP-ASI/8.0 CP-ASI/4.0 DC/DC L, N Frequency range AC Typical input current Power factor correction (PFC) CP-ASI/4.0 at 115 V AC at 230 V AC 184-264 V AC / 240-300 V DC 184-264 V AC 2.7 A 6.0 A 1.3 A 2.8 A max. 60 V DC / 42.4 V AC max. 5 Vpp, 47 Hz - 40 kHz 135 W < 44.7 A (120 V AC) / approx. 3.7 A²/s < 49.3 A (132 V AC) / approx. 4.6 A²/s < 49.7 A (230 V AC) / approx. 2.5 A²/s < 57.5 A (264 V AC) / approx. 3.3 A²/s 261 W < 12 A (100 V AC) / approx. 1.0 A²/s < 14 A (120 V AC) / approx. 1.5 A²/s < 24 A (220 V AC) / approx. 1.4 A²/s < 27 A (240 V AC) / approx. 1.6 A²/s 24 V DC 18.0-32.4 V DC 5.6 A max. 36.0 V DC typ. 17.5 V DC typ. 14.0 V DC typ. 35 V DC 132 W < 1.8 A / approx. 1.0 A²/s - < 3.5 mA max. 0.5 ms min. 35 ms min. 40 ms min. 20 ms min. 40 ms min. 30 ms varistors CP-ASI/4.0 DC/DC: included, unit does not start at reversed polarity 8 A slow acting / 3.15 A slow acting / 8 A slow acting / 10 A slow acting 250 V AC 250 V AC 250 V AC circuit breaker with C characteristic min 6 A, or alternatively 10 A with B characteristic 0.58 0.53 0.53 0.48 - AS-I OK LED green IR ADDRESSING ON LED red OVERLOAD +,30.5 V DC 85 W ±3% Ta m 60 °C 2.8 A - LED red 122 W 244 W 122 W 4.0 A 8.0 A 4.0 A Derating of the output current 60 °C < Ta m 70 °C 2.5 %/°C Signalling contact for ground fault CP-ASI/4.0: max. 25 V AC or 60 V DC, 0.5 A Control time < 2 ms Starting time after applying the supply voltage max. 400 ms max. 700 ms max. 500 ms Rise time max. 100 ms at rated load with 5 mF Residual ripple BW = 500 kHz typ. < 50 mVpp Switching peaks max. 1 s (typ. 650 ms) typ. 100 ms typ. 200 ms BW = 20 MHz typ. < 100 mVpp Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output U/I characteristic curve Short-circuit protection continuous short-circuit stability Overtemperature protection No-load protection CP-ASI/4.0 DC/DC: yes, automatic recovery after temperature went down continuous no-load stability Combined U/I characteristic curve and hiccup mode temporary shortcircuit stability - U/I characteristic curve continuous shortcircuit stability Short-circuit behaviour continuation with output power limiting continuation with output power limiting Current limiting at short circuit min / max 3.2 A / 4.6 A 4.2 A / 6.5 A 12 A / 25 A (max. 5 s) 5.0 A / 9.0 A Overload protection output power limiting temporary output output power power limiting limiting Overtemperature, overload and short circuit behaviour CP-ASI/8.0: at 8.4 A < I max < 12 A continuous current for 2-5 s, afterwards safety switch-off 3/61 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-ASI range Technical data Type General data CP-ASI/2.8 MTBF Power dissipation Efficiency Duty time Dimensions (W x H x D) product dimensions packaging dimensions Weight net weight gross weight Material of housing Mounting Mounting position Minimum distance to other units horizontal / vertical Degree of protection housing / terminals Protection class Electrical connection Wire size fine-strand with wire end ferrule fine-strand without wire end ferrule rigid Stripping length Tightening torque Environmental data Ambient temperature range operation rated load storage Vibration (sinusoidal) (IEC/EN 60068-2-6) sinusoidal (IEC/EN 60068-2-6) random (IEC 60068-2-64) Shock (half-sine) (IEC/EN 60068-2-27) Isolation data Rated insulation voltage U i input circuit / output circuit (IEC/EN 60950-1, EN 50178) input / PE output / PE shield / output shield / PE Rated impulse withstand voltage U imp input / output (EN 50178) input / PE output / PE Power-frequency withstand voltage input / output test (test voltage) (routine test / type test) input / PE Pollution degree (IEC/EN 60950-1) Overvoltage category (UL/IEC/EN 60950-1) Standards Low Voltage Directive EMC directive RoHS directive Electrical safety Protective low voltage Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst CP-ASI/4.0 CP-ASI/8.0 on request typ. < 9.1 W typ. < 13.5 W typ. < 21.2 W (230 V AC, 2.8 A) (230 V AC, 4.0 A) (230 V AC, 8.0 A) typ. 90.5 % typ. 90 % typ. 92.0 % 100 % 49 x 131 x 107 mm 73 x 131 x 107 mm 91 x 131 x 107 mm (1.93 x 5.16 x 4.21 in) (2.87 x 5.16 x 4.21 in) (3.58 x 5.16 x 4.21 in) 151 x 65 x 140 mm 151 x 98 x 140 mm 151 x 120 x 140 mm (5.94 x 2.56 x 5.51 in) (5.94 x 3.86 x 5.51 in) (5.94 x 4.72 x 5.51 in) 0.495 kg (1.019 lb) 0.653 kg (1.440 lb) 0.897 kg (1.997 lb) 0.568 kg (1.252 lb) 0.750 kg (1.653 lb) 1.015 kg (2.238 lb) metal DIN rail (IEC/EN 60715), snap-on mounting without any tool horizontal 15 mm / 25 mm (0.59 / 0.99 in) IP20 / IP20 I 40 x 131 x 107 mm (1.58 x 5.16 x 4.21 in) 151 x 65 x 140 mm (5.94 x 2.56 x 5.51 in) 0.488 kg (1.076 lb) 0.750 kg (1.287 lb) -10...+70 °C -10...+60 °C -25...+85 °C 2-17.8 Hz, amplitude ± 1.6 mm 17.8 Hz - 500 Hz, 2 g 2-800 Hz 0.5 s² (s³) 15 g (6 ms), 10 g (11 ms) -25...+70 °C -25...+60 °C -40...+85 °C 300 V 300 V 50 V 50 V 50 V 6 kV 1.2/50 μs 4 kV 1.2/50 μs 500 V 1.2/50 μs 2.5 kV AC / 3.0 kV AC 50 V 50 V 1.5 kV 1.2/50 μs 0.8 kV 1.2/50 μs 500 V 1.2/50 μs 1.5 kV AC / 1.5 kV AC 1.5 kV AC / 1.5 kV AC 2.5 kV AC / 2.5 kV AC output / PE 500 V AC / 500 V AC 2 input II (IEC/EN 60950-1), III (EN 50178) output II (IEC/EN 60950-1), II (EN 50178) 2006/95/EC 2004/108/EC 2011/65/EC IEC/EN 60950-1 SELV (IEC/EN 60950-1), PELV IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 4 (8 kV / 15 kV) IEC/EN 61000-4-3 Level 3 (10 V/m) IEC/EN 61000-4-4 input circuit: Level 4 (4 kV) IEC/EN 61000-4-5 input circuit: L-L Level 3 (2 kV) / L-PE Level 4 (4 kV) output circuit: Level 1 (0.5 kV) conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltag variations Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions typ. < 12.7 W (24 V DC, 4.0 A) typ. 90.5 % 0.5-4 mm² (20-12 AWG) 0.5-4 mm² (20-12 AWG) 0.5-6 mm² (20-10 AWG) 7 mm (0.28 in) 0.8 Nm (7.08 lb.in) output circuit: Level 3 (2 kV) surge CP-ASI/4.0 DC/DC IEC/EN 61000-4-6 Level 3 (10 V, 150 kHz - 80 MHz) IEC/EN 61000-4-11 Class 3 IEC/EN 61000-6-3 IEC/CISPR 22, EN 55022 Class B IEC/CISPR 22, EN 55022 Class B IEC/EN 61000-3-2 Class A input circuit: Level 3 (2 kV) output circuit: Level 2 (1 kV) input circuit: L-L Level 2 (1 kV) / L-PE Level 3 (2 kV) output circuit: Level 1 (0.5 kV) Level 3 (10 V, 150 kHz - 80 MHz) IEC/EN 61000-6-4 IEC/EN 61000-6-3 - - 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/62 3 CP-ASI range Technical diagrams Characteristic curve at Ta = 25 °C CP-ASI 2.8 Uout [V] Iout [A] 32 2.8 24 20 8 4 0 0 1 2 3 Iout [A] 4 2CDC 272 007 F0012 12 -10 60 2CDC 272 006 F0212 2.1 16 70 Ta [°C] Characteristic curve of temperature at rated load Output behaviour CP-ASI 4.0 DC/DC Uout [V] Iout [A] 35 4 30 25 3 20 5 0 0 1 2 3 4 5 6 8 Iout [A] 7 -25 60 70 2CDC 272 010 F0212 10 2CDC 272 011 F0012 15 Ta [°C] Characteristic curve of temperature at rated load Output behaviour CP-ASI 4.0 Uout [V] 35 Iout [A] 30 4 20 3 2CDC 272 009 F0012 15 10 5 0 0 1 2 3 4 5 6 Iout [A] 2CDC 272 008 F0212 25 -10 Output behaviour 60 70 Ta [°C] Characteristic curve of temperature at rated load CP-ASI 8.0 Uout [V] Iout [A] 35 30 8 25 15 10 5 0 0 2 4 6 Output behaviour 8 10 12 Iout [A] 2CDC 272 012 F0212 6 20 2CDC 272 013 F0012 3 28 -10 60 70 Ta [°C] Characteristic curve of temperature at rated load 3/63 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-ASI range Dimensional drawings Dimensions in mm/inch CP-ASI 2.8 CP-ASI 4.0 DC/DC 102 4.02” 102 4.02” 49 1.93” 94 3.78” 62 2.44” 40 1.58” 2CDC 272 016 F0012 62 2.44” 2CDC 272 014 F0012 62 2.44” 5 0.20” 3 131 5.16” 131 5.16” 62 2.44” 94 3.78” 5 0.20” CP-ASI 4.0 CP-ASI 8.0 102 4.02” 102 4.02” 94 3.78” 94 3.78” 73 2.87” 91 3.58” 5 0.20” 131 5.16” 2CDC 272 017 F0012 62 2.44” 62 2.44” 2CDC 272 015 F0012 62 2.44” 131 5.16” 62 2.44” 5 0.20” 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/64 CP-B range Product group picture 3 3/65 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-B range Table of contents CP-B Product group picture 3/65 Table of contents 3/66 Benefits and advantages 3/67 Ordering details 3/68 Technical data 3/69 Technical data, Technical diagrams 3/70 Dimensional drawings 3/71 Technical data 3/72 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/66 3 CP-B range Benefits and advantages Power supply systems have to be highly reliable in most areas of energy management and automation technology. Often batteries are used for supporting the supply system in case of mains failures. Batteries have limited lifetimes depending on environmental parameters and have to be maintained regularly, which causes efforts and costs. 3 Characteristics – – 3 buffer modules for buffering 24 V DC: CP-B 24/3.0 (3 A / 1 kWs1)) CP-B 24/10.0 (10 A / 10 kWs1)) CP-B 24/20.0 (20 A / 8 kWs1)) – – CP-B 24/3.0 and CP-B 24/20.0 expandable with additional extension module(s) CP-B EXT.2 (2 kWs1)) – – LEDs for status indication – – Relay contacts for status messaging – – Very high backup times (e.g. with CP-B 24/10.0 up to 8 minutes at 1 A load current) – – Short charging times – – High efficiency, higher than 90% – – Wide temperature range – – DIN rail mountable, compact housing Using the latest ultra-capacitor technology, ABB offers an innovative and completely maintenance free new product for buffering the 24 V DC supply in case of interrupted mains on the primary side of the switch mode power supply. The CP-B range is an ultra-capacitor buffer energy storage for power supply units which ensures a short term uninterrupted power supply system. In case of a power loss, the energy stored in the capacitor guarantees that the load is continually provided up to several hundred seconds depending on the load current. Advantages in comparison to battery buffers: – – Maintenance free – – No deep discharge – – Temperature resistant – – A (UL508, CSA22.2 No 14), R approvals 1) Order code Rated input voltage Rated current Energy storage (min.) Typical charging time at load current Typical buffering time1) at load current 1) buffering time ≈ 100 0 100 50 25 10 % % % % % % internal energy buffer CP-B 24/3.0 CP-B 24/10.0 CP-B 24/20.0 CP-B EXT.2 1SVR427060R0300 24 V DC 3 A DC 1.000 Ws 65 s 56 s 13 s 28 s 66 s 148 s 1SVR427060R1000 24 V DC 10 A DC 10.000 Ws 134 s 82 s 38 s 76 s 140 s 380 s 1SVR427060R2000 24 V DC 20 A DC 8.000 Ws 135 s 62 s 15 s 30 s 60 s 150 s 1SVR427065R0000 – 3 A DC 2.000 Ws energy storage x 0.9 current x output voltage 1 Input terminals SHUT-DOWN+, SHUT-DOWN-: Input signal terminals INPUT OK, BUFFER STATUS, FAILURE: Signalling contact – terminals L+IN, L-IN: Input voltage terminals 2 Indication of operational states 1 OPERATION: Buffer module in operation (standby or buffering) INPUT OK: Input voltage applied 3 Output terminals 2 1 3 3/67 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 L+OUT, L-OUT, L-OUT: Output voltage terminals CP-B range Ordering details 2CDC 271 001 S0010 Description CP-B 24/3.0 Ultra capacitor based buffer units of the CP-B range offer highest reliability also in harsh enivronment. Due to the ultra-cap based technology the units are maintenance free, there will be no deep discharge and these products offer a very wide operational ambient temperature range. CP-B range buffer units are an excellent solution to avoid voltage drops, for example in solar applications. 3 Ordering details Rated input voltage Rated current Type Order code Price 1 pce 2CDC 271 002 S0010 24 V DC CP-B 24/10.0 Weight (1 pce) kg (lb) 3 A DC CP-B 24/3.0 1SVR427060R0300 0.55 (1.21) 10 A DC CP-B 24/10.0 1SVR427060R1000 2.10 (4.63) 20 A DC CP-B 24/20.0 1SVR427060R2000 2.20 (4.85) Ordering details - Extension unit for CP-B 24/3.0 and CP-B 24/20.0 Rated voltage Voltage range Type Order code Price 1 pce 0-26.4 V DC CP-B EXT.2 1SVR427065R0000 1.00 (2.20) Example of application L N L+ L- CP-C 24/20.0 2CDC 271 003 S0010 24 V DC Weight (1 pce) kg (lb) CP-B 24/20.0 max. 20 A L-IN L+OUT L-OUT CP-B 24/10.0 L+IN max. 10 A L+ buffered L+ L- unbuffered L- load 1 ... load n load 1 ... load n 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/68 CP-B range Technical data Type 3 CP-B 24/3.0 Input circuit - Supply circuit Rated input voltage U in Input voltage range Minimum charging potential Rated input current Inrush current limiting Transient overvoltage protection Internal input fuse (apparatus protection, not accessible) Internal fuse capacitors circuit (not accessible) Kind of input Output circuit Rated output power Rated output voltage Uout Output voltage (buffer mode) Tolerance of the output voltage Rated output current Ir Peak output current (fully loaded capacitors required) Control of limiting current Shut-down if limiting current is exceeded Short-circuit protection (only via external fuse) Internal output fuse (not accessible) Required external fuse Current limiting at output circuit Breaking capacity of output circuit Power failure buffering time 1) CP-B 24/10.0 CP-B 24/20.0 L+IN L-IN 24 V DC 23.7-26.4 V DC 23.7 V DC 3 A DC 50 A / 1 ms suppressor diode 4 A slow acting SHUT-DOWN rated voltage voltage range 69 W 24 V DC 23.0 V DC +2...-10 % Ta 60 °C 3 A DC 23.9-27 V DC 23.9 V DC 10 A DC 35 A / 2 ms varistor / suppressor diode 15 A (FK2) 25 A (FK2) control input 24 V DC 6-45 V DC L+OUT L- OUT L- OUT 240 W 23.4-27.4 V DC 23.4 V DC 20 A DC 35 A / 2 ms varistor / suppressor diode 30 A (FK2) 23.2 V DC 23.2 V DC 10 A DC 20 A DC Ta 60 °C 6 A DC (min. 1.5 s) 20 A DC (10 A power supply + 10 A CP-B, min. 1.5 s) 10.3 A DC w0.1A after 1.5 s no continuous short-circuit stability 15 A (FK2) 3.15 A slow acting 10 A slow acting 1.05...1.2 x I r t= 2.5 ms load-dependent, min. 13 s at 100 % load Overload protection Kind of output control input 24 V DC 6-45 V DC 480 W 40 A DC (min. 1.5 s) 25 A slow acting - 24 V DC, 10 A - load-dependent, min. 38 s at 100 % load load-dependent, min. 15 s at 100 % load thermal protection INPUT OK n/o contact BUFFER STATUS n/o contact FAILURE c/o contact Contact material Ag + Au-clad Minimum switching voltage / Minimum switching current 5 V DC / 1 mA Maximum switching voltage / Maximum switching current 50 V AC / 1.0 A, 30 V DC / 0.5 A Mechanical lifetime 5 x 10 6 switching cycles Electrical lifetime 0.1 x 10 6 switching cycles Maximum fuse rating to achieve short-circuit protection n/o or n/c contact 1.0 A AC / 0.5 A DC General data Maximum internal power consumption 7W 20 W 40 W Power consumption with unloaded output 0.75 W 3W 1.6 W Energy storage (min.) 1000 Ws 10000 Ws 8000 Ws 100 % 65 s 134 s 135 s Typical charging time at load current 0 % 56 s 82 s 62 s 100 % 13 s 38 s 15 s Typical buffering time at load current1) 50 % 28 s 76 s 30 s 25 % 66 s 140 s 60 s 10 % 148 s 380 s 150 s Efficiency greater than 90 % Dimensions (W x H x D) product dimensions 60 x 99 x 120 mm 116 x 170 x 147 mm 84 x 197 x 213 mm (2.36 x 3.90 x 4.72 in) (4.57 x 6.69 x 5.79 in) (3.31 x 7.76 x 8.39 in) Weight net weight 0.55 kg (1.21 lb) 2.1 kg (4.63 lb) 2.2 kg (4.85 lb) Material cover / housing shell steel sheet powdered Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal not necessary vertical 40 mm (1.58 in) 80 mm (3.15 in) Pollution degree 2 Degree of protection housing / terminal IP20 Protection class (IEC/EN 61140) III SELV / PELV (condition: power supply fulfills class III) Electrical connection - Input circuit / Output circuit pull spring terminals pull spring terminals pluggable screw type terminals Wire size fine-strand with(out) wire end ferrule 0.08-1.0 mm ² 0.08-1.5 mm ² 0.2-4.0 mm ² (28-18 AWG) (28-18 AWG) (24-12 AWG) rigid 0.08-1.5 mm ² 0.08-4.0 mm ² 0.2-6.0 mm ² (28-16 AWG) (28-16 AWG) (24-10 AWG) Stripping length 6.0 mm (0.24 in) 7.0 mm (0.28 in) 3/69 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CP-B range Technical data, Technical diagrams Type CP-B 24/3.0 Input circuit - Supply circuit Signalling circuit Wire size CP-B 24/10.0 CP-B 24/20.0 L+IN L-IN fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG) rigid 0.08-1.5 mm² (28-16 AWG) 6.0 mm (0.24 in) Stripping length Environmental data Ambient temperature 0.14-1.0 mm² (26-16 AWG) 0.14-1.5 mm² (28-16 AWG) 7.0 mm (0.28 in) operation -40...+60 °C storage -40...+60 °C Standards Product standard Low Voltage Directive EMC Directive RoHS Directive Electrical safety Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge conducted disturbances, induced by radiofrequency fields voltage dips, short interruptions and voltage variations Interference emission high-frequency radiated high-frequency conducted -20...+60 °C -20...+60 °C 3 EN 50178 2006/95/EC 2004/108/EC 2011/65/EC EN 50178, EN 60950, UL 508 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-6-1, IEC/EN 61000-6-2 Level 3, 6 kV / 8 kV Level 3, 10 V/m (27-1000 MHz) / Level 2, 3 V/m (1400-2700 MHz) Level 3, 2(1) kV / 5 kHz Level 1, 0.5 kV Level 3, 10 V (150 kHz-80 MHz) IEC/EN 61000-4-11 buffered by ultra-capacitors EN 61000-6-3, EN 61000-6-4 DIN EN 55011 B/C1 DIN EN 55011 B/C1 „Approvals and marks“ on page 3/4. 1) energy storage x 0.9 load current x output voltage buffering time ≈ Technical diagrams Output curve at Ta = 25 °C Normal application (up to 50 % buffer mode, 5 charging and discharging cycles in direct series) Continuous charging and discharging in direct series. As this is not typical of a real application, this should be considered as theoretical indication 1.5 Ta [°C] 0 20 40 60 10 CP-B 24/3.0 0 20 40 60 Continuous charging and discharging in direct series. As this is not typical of a real application, this should be considered as theoretical indication 7.5 5.0 Ta [°C] 20 40 60 CP-B 24/10.0 Caracteristic curve of the temperature at rated load 60 50 40 30 2CDC 272 029 F0210 10.0 Years Normal application (up to 50 % buffer mode, 5 charging and discharging cycles in direct series) 0 Ta [°C] -20 CP-B 24/20.0 Iout [A] -40 Continuous charging and discharging in direct series. As this is not typical of a real application, this should be considered as theoretical indication 15 20 10 0 10 20 30 40 50 60 70 2CDC 272 031 F0210 -40 Normal application (up to 50 % buffer mode, 5 charging and discharging cycles in direct series) 20 2CDC 272 028 F0210 3.0 Iout [A] 2CDC 272 030 F0210 Iout [A] Temperature [°C] Capacitor's life span over temperature 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/70 CP-B range Dimensional drawings 119 4.69‘‘ 120 4.72‘‘ CP-B 24/3.0 193 7.60‘‘ 197 7.76‘‘ 188 7.40‘‘ 84 3.31‘‘ 196 7.72‘‘ 213 8.39‘‘ 2CDC 272 039 F0010 112 4.41‘‘ 2CDC 272 037 F0010 99 3.90‘‘ 60 2.36‘‘ CP-B 24/10.0 138 5.43‘‘ 146 5.75‘‘ 147 5.79‘‘ 93 3.66‘‘ 60 2.36‘‘ 112 4.41‘‘ 119 4.69‘‘ 120 4.72‘‘ CP-B EXT.2 3/71 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 2CDC 272 036 F0010 116 4.57‘‘ 2CDC 272 038 F0010 99 3.90‘‘ 163 6.42‘‘ CP-B 24/20.0 170 6.69‘‘ 3 93 3.66‘‘ Dimensions in mm and inches CP-B range Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated Type CP-B EXT 2.0 Extension circuit EXT+ EXT+ EXT- EXT- Rated voltage 24 V DC Voltage range 0-26.4 V DC Rated current 3 A DC Internal input fuse (apparatus protection, not accessible) 4 A slow acting (PTC) Short-circuit protection via internal 3 A fuse Overload protection only in combination with CP-B 24/3.0 or CP-B 24/20.0 Indication of operational states status information and fault messages of the buffer module apply General data Power consumption without load 0.5 W Energy storage (min.) 2000 Ws Dimensions (W x H x D) product dimensions 60 x 99 x 120 mm (2.36 x 3.90 x 4.72 in) packaging dimensions 85 x 220 x 170 mm (3.35 x 8.66 x 6.69 in) Weight net weight 1.00 kg (0.20 lb) Material cover / housing shell steel sheet powdered Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal not necessary vertical 40 mm (1.58 in) Pollution degree 2 Degree of protection housing / terminal IP20 Protection class (IEC/EN 61140) Electrical connection - Extension circuit Wire size III SELV / PELV (condition: power supply fulfills class III) fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG) rigid 0.08-1.5 mm² (28-16 AWG) Stripping length 6.0 mm (0.24 in) Signalling circuit Wire size fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG) rigid 0.08-1.5 mm² (28-16 AWG) Stripping length Environmental data Ambient temperature Vibration, sinusoidal Shock, half-sine 6.0 mm (0.24 in) operation -40...+60 °C storage -40...+60 °C based on IEC/EN 60068-2-6 1.5 mm, 3-57.55 Hz; 2 g, 57.55-500 Hz, 10 cycles based on IEC/EN 60068-2-27 15 g, 11 ms, 3 axes, 6 faces, 3 times for each face Standards Product standard EN 50178 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2011/65/EC Electrical safety EN 50178, EN 60950, UL 508 Electromagnetic compatibility Interference immunity to electrostatic discharge IEC/EN 61000-6-1, IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m (27-1000 MHz) / Level 2, 3 V/m (1400-2700 MHz) electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2(1) kV / 5 kHz surge IEC/EN 61000-4-5 Level 1, 0.5 kV conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations IEC/EN 61000-4-6 Level 3, 10 V (150 kHz-80 MHz) Interference emission IEC/EN 61000-4-11 buffered by ultra-capacitors EN 61000-6-3, EN 61000-6-4 high-frequency radiated DIN EN 55011 B/C1 high-frequency conducted DIN EN 55011 B/C1 „Approvals and marks“ on page 3/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/72 3 Electronic protection devices EPD24 Product group picture 3 3/73 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Electronic protection devices EPD24 Table of contents Electronic protection devices EPD24 Product group picture 3/73 Table of contents 3/74 Ordering details 3/75 Technical data 3/76 Technical information 3/78 Approvals, safety instructions 3/79 Installation guidelines 3/80 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/74 3 Electronic protection devices EPD24 Ordering details 2CDC 051 001 S0010 3 EPD24-TB-101-3A The protection devices EPD24 extend the ABB product range of Modular DIN rail components by electronic overcurrent protection modules for selective protection of 24 V DC load circuits. This protection is achieved by a combination of active electronic current limitation in the case of a short circuit and an overload deactivation from 1.1 x In upwards. If a fault occurs in a load circuit, the protection device EPD24 will detect this rapidly and reliably, disable the power output transistor and hence interrupt the current flow in the defective circuit. The maximum possible overcurrent is always limited to 1.3…1.8 times the selected rated current. An activation of capacitive loads up to 20,000 μF is possible, deactivation only occurring in the case of overloads or short circuits. Selective deactivation of the defective current circuit means undefined error states and a complete system stop are prevented. Features –– Selective load protection, one electronic tripping characteristic. –– Active current limitation for safe connection of capacitive loads up to 20,000 µF and on overload/short circuit. –– Current ratings 0.5 A...12 A. –– Reliable overload disconnection with 1.1 x IN –– Manual ON/OFF button –– Clear status and failure indication through LED and integrated auxiliary contact. –– Integral fail-safe element adjusted to current rating. –– Width per unit only 12.5 mm. –– Rail mounting –– Ease of wiring through busbar LINE+ and 0 V as well as signal bars. –– UL- and CSA-approvals allow international use of the devices. Ordering details Ratedcurrent IN bbn 40 16779 EAN Type Order code Price 0.5 829960 EPD24-TB-101-0.5A 2CDE601101R2905 4 1 829984 EPD24-TB-101-1A 2CDE601101R2001 4 2 830003 EPD24-TB-101-2A 2CDE601101R2002 4 3 830027 EPD24-TB-101-3A 2CDE601101R2003 4 4 830041 EPD24-TB-101-4A 2CDE601101R2004 4 6 830065 EPD24-TB-101-6A 2CDE601101R2006 4 8 830089 EPD24-TB-101-8A 2CDE601101R2008 4 10 830102 EPD24-TB-101-10A 2CDE601101R2010 4 12 830126 EPD24-TB-101-12A 2CDE601101R2012 4 A Pkg qty Weight (1 pce) kg (lb) 0.065 (1.433) 0.065 (1.433) 0.065 (1.433) 0.065 (1.433) 0.065 (1.433) 0.065 (1.433) 0.065 (1.433) 0.065 (1.433) 0.065 (1.433) Ordering details Description bbn 40 Type 16779 EAN Busbars for LINE+ and 0 V, 830140 grey insulation, length 500 mm 1) Signal Bars for aux. contacts, grey 830164 insulation, length 21 mm 1) Price Pkg qty EPD-BB500 2CDE605100R0500 10 EPD-SB21 2CDE605200R0021 10 ax. load with one line entry Imax = 50 A (recommended: mid line entry) M Max. load with two line entries Imax = 63 A 3/75 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Order code Weight (1 pce) kg (lb) 0.2 (0.441) 0.4 (0.882) her Sicherungsautomat ESX10-T - und Sicherheitshinweise Electronic protection devices EPD24 Technical data Signaleingänge/-ausgänge (Anschlussdiagramme) Wiring diagramm sgänge (Anschlussdiagramme) EPD24-TB-101 gezeigt us- oder Fehlerzustand K without signal input with signal output F (Single signal, N/O) ESX10-TB-101 Operating condition: 13-14 closed Ohne FaultSignaleingang condition: 13-14 open Mit Meldeausgang F (Einzelsignal, Schließer) LINE+ 24 V DC (18...32 V) Current rating I N fixed current ratings: 0.5, 1, 2, 3, 4, 6, 8, 10, 12 A Closed current I 0 ON condition: typically 20...30 mA depending on signal output Staus indication by means of Green: unit is ON load circuit / Power-MOSFET is switched on Orange: in the event of overload or short circuit until electronic disconnection Red: unit electronically disconnected load circuit/Power-MOSFET OFF undervoltage (U B < 8 V) after switch-on till the end of the delay period OFF: manually switched off or device is dead potential-free auxiliary contact F ON/OFF/ condition of switch ESX10-TB-102 Ohne Signaleingang Mit Meldeausgang F (Einzelsignal, Öffner) 1 1 LINE+ 12 14 Load circuit 11 Load output Overload disconnection Short-circuit current I K Trip time 13 2 Operating data Operating voltage U B LOAD+ 2 Power-MOSFET switching output (high slide switch) typically 1.1 x I N (1.05...1.35 x I N) active current limitation see time/current characteristics LOAD+ For electronic disconnection Temperature disconnection Low voltage monitoring load output 0V 3 Normalzustand: 13-14 geschlossen Fehlerzustand: 13-14 geöffnet ESX10-TB-124 Mit Reseteingang RE (+DC 24 V ↓) Mit Statusausgang SF (+24 V = Lastausgang EIN) LINE+ 1 Starting delay t Start 3 0V Disconnection of load circuit Normalzustand: 11-12 geöffnet Free-wheeling circuit Fehlerzustand: SF 23 RE 22 RE 22 2 LOAD+ 0V 3 Normalzustand: SF +24 V = OK Fehlerzustand: SF 0 V 5 suitable external free-wheeling circuit to be used with inductive 11-12 geschlossenload Several load outputs must not be connected in parallel Signal output Electrical data potential-free auxiliary contact max. 30 V DC/0.5 A, min. 10 V DC/10 mA ON condition LED green voltage U B applied, switch is in ON position no overload, no short circuit ESX10-TB-127 OFF LED offRE device switched off (switch is in OFF position) Mitcondition Reseteingang no voltage U B applied (+DC 24 V ↓) Fault condition LED orange overload condition > 1.1 x I N up to electronic disconnection Mit Statusausgang SF invertiert Fault LED red EIN) electronic disconnection upon overload or short circuit (0 Vcondition = Lastausgang Device switched off with control signal (switch is in ON position) Aux. contact single signal, make contact 1 LINE+ contact open, terminal 13-14 Fault signal output fault conditions no operating voltage U B ON/OFF switch is in OFF position red LED lighted (electronic disconnection) SF 23 2 typically 3 s at I Load > 1.1 x I N typically 100 ms...3 s at I Load > 1.8 x I N (or 1.5 x I N /1.3 x I N, ) internal temperature monitoring with electronic disconnection with hysteresis, no reset required: load »OFF« at U B< 8 V typically 0.5 sec after every switch-on and after applying U B electronic disconnection LOAD+ 0V 3 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/76 Normalzustand: SF 0 V = OK Fehlerzustand: SF +24 V 3 Electronic protection devices EPD24 Technical data General data Dimensions (B x H x T) backup fuse for EPD24 not required because of the integral redundant fail-safe element moulded symmetrical rail to EN 50022-35x7.5 0...+50 °C (without condensation, see EN 60204-1) -20...+70 °C 96 hrs/95 % RH/40 °C to IEC 60068-2-78, test Cab. climate class 3K3 to EN 60721 3 g, test to IEC 60068-2-6 test Fc housing: IP20 DIN 40050 terminals: IP20 DIN 40050 emission: EN 61000-6-3 susceptibility: EN 61000-6-2 0.5 kV/pollution degree 2 reinforced insulation in operating area max. 32 V DC (load circuit) n/a, only electronic disconnection UL 2367 Solid State Overcurrent Protectors UL 1604, (class I, division 2, groups A, B, C, D) UL 508 CSA C22.2 No. 213 (class I, division 2) CSA C22.2 No. 142 CE logo 12.5 x 80 x 83 mm Weight approx. 65 g Terminals Line+/LOAD+/0V Screw terminals M4 Max. cable cross section flexible with wire end ferrule w/wo plastic sleeve 0.5 – 10 mm 2 Multi-lead connection (2 identical cables) rigid/flexible 0.5 – 4 mm 2 Flexible with wire end ferrule without plastic sleeve 0.5 – 2.5 mm 2 Flexible with TWIN wire end ferrule with plastic sleeve 0.5 – 6 mm 2 Wire stripping length 10 mm Tightening torque (EN 60934) 1.5 – 1.8 Nm Terminals aux. contacts Screw terminals M3 Max. cable cross section flexible with wire end ferrule w/wo plastic sleeve 0.25 - 2.5 mm 2 Wire stripping length 8 mm Tightening torque (EN 60934) 0.5 Nm Fail-Safe element Housing material Mounting Ambient temperature Storage temperature Humidity 3 Vibration Degree of protection EMC (EMC directive, CE logo) Isolations coordination (IEC 60934) Dielectric strength Isolation resistance (OFF condition) Approvals/Declarations of conformity Table 1: voltage drop, current limitation, max. load current current rating IN typically voltage drop UON at IN active current limitation (typically) max. load current at 100 % ON duty Tambient = 40 °C Tambient = 40 °C 0.5 A 1A 2A 3A 4A 6A 8A 10 A 12 A 70 mV 80 mV 130 mV 80 mV 100 mV 130 mV 120 mV 150 mV 180 mV 1.8 1.8 1.8 1.8 1.8 1.8 1.5 1.5 1.3 0.5 A 1A 2A 3A 4A 6A 8A 10 A 12 A x x x x x x x x x IN IN IN IN IN IN IN IN IN 0.5 A 1A 2A 3A 4A 5A 7A 9A 10.8 A Attention: when mounted side-by-side without convection the ERD24 should not carry more than 80 % of its rated load with 100 % ON duty due to thermal effects. 3/77 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Electronic protection devices EPD24 Technical information Time/Current characteristic curve (Tambient = 25 °C) The trip time is typically 3 s in the range between 1.1 and 1.8 x IN1). Electronic current limitation occurs at typically 1.8 x IN1) which means that under all overload conditions (independent of the power supply and the resistance of the load circuit) the max. overload before disconnection will not exceed 1.8 x IN1) times the current rating. Trip time is between 100 ms and 3 sec (depending on overload or at short circuit). Without this current limitation a considerably higher overload current would flow in the event of an overload or short circuit. disconnection typically 1.1 x IN 1.8 x IN1) 3 10000 1000 trip time in seconds 100 current limitation 1) typically 1.8 x IN 10 5 1 0. 1 0.01 0 1 2 4 3 1) 5 IK ...times rated current urrent limitation typically 1.8 x IN at IN = 0.5 A...6 A C Current limitation typically 1.5 x IN at IN = 8 A or 10 A Current limitation typically 1.3 x IN at IN = 12 A Maximum cable lenghts EPD24 reliably trips from 0 Ω up to max. circuit resistance R max. Calculation of Rmax Selected rating I N (A) 3 6 19.2 19.2 Trip current I ab = 1.25 x I N (A) (EPD24 trips after 3 s) 3.75 7.50 Rmax (Ω) = (UB/Iab) -0.050 5.07 2.51 Operating voltage U S (V DC) (= 80 % of 24 V) 2) 2) Voltage drop of EPD24 and tolerance of trip point (typically 1.1 x I N = 1.05 ... 1.35 x I N) have been taken into account Selection table for the incoming cable lengths with different cable cross-sections Cable cross section A (mm 2) Cable length L (m) (= single length) 5 10 15 20 25 30 35 40 45 50 75 100 125 150 175 200 225 250 Resistivity of copper ρ0 = 0.0178 (Ω x mm2)/m Example 1: max. length for 1.5 mm2 and 3 A: 214 m Example 2: max. length for 1.5 mm2 and 6 A: 106 m 3) 0.14 0.25 0.34 cable resistance (Ω) = (ρ0 x 2 x L) / A 1.27 0.71 0.52 2.54 1.42 1.05 3.81 2.14 1.57 5.09 2.85 2.09 6.36 3.56 2.62 7.63 4.27 3.14 8.90 4.98 3.66 10.17 5.70 4.19 11.44 6.41 4.71 12.71 7.12 5.24 19.07 10.68 7.85 25.34 14.24 10.47 31.79 17.80 13.09 38.14 21.36 15.71 44.50 24.92 18.32 50.86 28.48 20.94 57.21 32.04 23.56 63.57 35.60 26.18 0.5 0.75 1.00 1.50 0.36 0.71 1.07 1.42 1.78 2.14 2.49 2.85 3.20 3.56 5.34 7.12 8.90 10.68 12.46 14.24 16.02 17.80 0.24 0.47 0.71 0.95 1.19 1.42 1.66 1.90 2.14 2.37 3.56 4.75 5.93 7.12 8.31 9.49 10.68 11.87 0.18 0.36 0.53 0.71 0.89 1.07 1.25 1.42 1.60 1.78 2.67 3.56 4.45 5.34 6.23 7.12 8.01 8.90 0.12 0.24 0.36 0.47 0.59 0.71 0.83 0.95 1.07 1.19 1.78 2.37 2.97 3.56 4.15 4.75 5.34 5.93 3) Example 3: mixed wiring: (Control cabinet --- sensor/actuator level) R1 = 40 m for 1.5 mm2 and R2 = 5 m for 0.25 mm2: R1 = 0.95 Ω, R2 = 0.71 Ω, total (R1 + R2) = 1.66 Ω 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/78 Electronic protection devices EPD24 Approvals, Safety instructions Please note The user must ensure that the cable cross sections of the relevant load circuit are suitable for the current rating of the EPD24 used. Automatic start-up of machinery after shut down must be prevented (Machinery Directive 98/37/EG and EN 60204-1). In the event of a short circuit or overload the load circuit will be disconnected electronically by the EPD24. 3 Information on UL approvals/CSA approvals UL1604 UL File # E 339238 CSA C22.2 No. 213 (Class I, Division 2) CSA File # 2305929 Operating Temperature Code T5 –– This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only WARNING: –– Exposure to some chemicals may degrade the sealing properties of materials used in the following device: relay Sealant Material: –– Generic Name: Modified diglycidyl ether of bisphenol A –– Supplier: Fine Polymers Corporation –– Type: Epi Fine 4616L-160PK –– Casing Material: –– Generic Name: Liquid Crystal Polymer –– Supplier: Sumitomo Chemical –– Type: E4008, E4009, or E6008 RECOMMENDATION: –– Periodically inspect the device named above for any degradation of properties and replace if degradation is found WARNING – EXPLOSION HAZARD: –– Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous –– Substitution of any components may impair suitability for Class I, Division 2 UL2367 Non-hazardous use - UL File # E 339236 UL 508 Non-hazardous use - UL File # E 149922 CSA C22.2 No. 14 CSA C22.2 No. 142 - CSA File # E 2305929 Class 2 Meets requirement for Class 2 current limitation (EPD24 ... -0,5 A/1 A/2 A/3 A) 3/79 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Electronic protection devices EPD24 Installation guidelines The EPD24 features an integral power distribution system. The following wiring modes are possible with various pluggable current and signal busbars: –– LINE+ (24 V DC) –– 0 V Caution: The electronic devices EPD24 require a 0 V connection –– Auxiliary contacts LINE+ busbar 2CDE605100R0500 continuous busbar 500 mm length, cut 3 (12.5 x n)-3 = length of busbars ± 0.5 e. g. (12.5 x 5)-3 = 59.5 ± 0.5 signal bar 2CDE605200R0021 remove protection against brush contact from bottom side insert protection against brush contact 0 V busbar 2CDE605100R0500 12.5 x n = width of protector block e. g. 12.5 x 5 = 62.5 insert busbars and protection slides to be flush with housing sides insert signal bars to be flush with housing and place them centrally over the contacts Mounting procedure Before wiring insert busbars into protector block. A maximum of 10 connection cycles are permissible using connecting busbars. Recommendation After 10 units the busbars should be interrupted and receive a new entry live. Table of length for busbars (Order code 2CDE605100R0500) No. of units Length of busbar (mm) ± 0.5 mm 2 22 3 34.5 4 47 5 59.5 6 72 7 84.5 8 97 9 109.5 10 122 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/80 Analog signal converters, Serial data converters Product group picture 4 4/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Analog signal converters, Serial data converters Table of contents Analog signal converters, serial data converters Overview 4/3 Analog signal converters - CC-E range............................................... 4/5 Table of contents 4/6 Benefits and advantages 4/7 Ordering details - Standard signal converters 4/8 Ordering details - RTD converters 4/9 Ordering details - Thermocouple converters 4/10 Ordering details - Measuring converters 4/11 DIP switch settings, Dimensional drawings 4/12 Wiring instructions 4/13 Technical data 4/14 Analog signal converters - CC-U range............................................. 4/17 Table of contents 4/18 Overview 4/19 Ordering details 4/21 Ordering details - Accessories 4/22 DIP switch settings 4/23 Wiring instructions 4/25 Technical information 4/26 Technical data 4/29 Technical diagr., Connection diagr., Dimensional drawings 4/32 Serial data converters...................................................................... 4/33 Table of contents 4/34 Benefits and advantages 4/35 Selection table 4/36 Ordering details 4/37 Technical information 4/38 Technical data 4/46 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/2 4 Analog signal converters, Serial data converters Overview Applications for analog signal processing and correct solution using CC-E and CC-U converters 0-10 V Controller e.g. AC500 1. Analog signal converter (e.g. CC-E or CC-U) 100 m 2. Analog signal converter (e.g. CC-E or CC-U) 0-20 mA 100 m 4-20 mA Actuator Signal conversion Sometimes the available signals cannot be processed by the controller or the actuator. In this case, signal converters are required to convert the input signal (or different input signals) to the desired output signal. Signal filtering Particularly on long lines or in rough industrial environments the signals are exposed to high electromagnetic interferences. The frequency of the coupled interference signals may be in the range of the common mains frequency (50 Hz) or even much higher (in case of frequency converters). According to the specific requirements, analog signal converters are available which provide reliable suppression of those interferences by means of an input low-pass filter. Measuring sensor 2CDC 282 013 F0206 Signal amplification If long lines or high burdens have to be operated, it may be necessary to amplify the signal. CC analog signal converters require only low input power and provide high output power. Thus, there are no restrictions for the converter's position on the line, i.e. it can be used – – for signal refreshing (1) at the end of the line (low input power) – – or for signal amplification (2) at the beginning of the line (high output power). Signal separation – – Protection against overvoltage The increased use of micro-electronics make controls much more sensitive against overvoltages, resulting from lightning discharges or switching processes. Suppression diodes are incorporated in the input of the CC analog signal converters which enable the converters to arrest overvoltages with low energy level (resulting from switching processes) by themselves. The products furthermore provide electrical isolation between input, output and supply circuit for protection of the controller connected to the output. – – Protection against ground loops If components are used which refer to ground, the measuring signals can be falsified by a so-called ground loop. In this case, certain parts of the signal are transmitted via earth and not via the analog transmission line, thus causing incorrect evaluation of the signal. The electrical isolation between the input and the output disconnects these ground loops and thus enables correct signal transmission. K E J J CC-U/V J CC-U/I J G CC-E I AC/ILPO J J CC-E/I J CC-U/TCR J G CC-U/TC J J CC-E/TC J CC-U/RTDR J CC-U/RTD CC-U/STDR J 508, CAN/CSA C22.2 No.14 UL 1604 (Class I, Div 2, hazardous locations), G CAN/CSA C22.2 No.213 CB scheme CCC CC-E/RTD A CC-U/STD Approvals A UL CC-E I/I J existing G existing for some devices j pending CC-E/STD 4 Nearly every process includes a control system that receives data by means of analog signals and then evaluates the data and sets the respective parameters correspondingly. When transmitting analog signals numerous problems may arise which can disturb or even block an ideal behavior of the process. Below we have listed some processing problems together with the respective solutions to solve these problems: 0-10 V J J J J G J J J J J J J J Marks a CE J J J J J J J J J J J J J J b C-Tick J J J J J J J J J J J J J J 4/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Analog signal converters, Serial data converters Overview In the field of industrial data transmission, various processes of data transmission and interfaces are used today. Already existing systems need to be updated or connected to new devices for continuity of process. When new communication functions are not build-in, ABB propose a range of converters to be able to use from the standard RS232 or RS485, to the Ethernet open products or the Optical Fiber. Ethernet communication is now one of the main features need in open communication, ABB propose the e-ILPH to connect the serial devices to the web world. Uses Example : Adaptation The use of converters allows the connection of two devices using different interfaces. To add new equipment to existing installations. Electrical Isolation To protect sensitive equipment it is sometimes necessary to use converters which allow electrical isolation. RS-485 RS-232 4 Example : Line 1 Line 2 Power To cross a disturbed environment Some interfaces are more sensitive to noise. Electrically, it is preferable, in some cases, to change the interface or support. Type of connection RS232 RS422 RS485 CL OF Ethernet Immunity to noise Low High High High Very high High Type of connection RS232 RS422 RS485 CL OF Ethernet 1) Noisy elements RS-232 RS-422 RS-422 Example : RS-485 2-/4 wires RS-232 RS-232 Connection Point to point 12 points 32 points 5-6 points 32 points Point to point or multipoint RS-232 RS-232 RS-232 RS-232 Increase in the transmission and amplification distances of the signals Every connection has its own limits, to increase the communication distances you only have to change the type of link (converter) or amplify the signal (Repeater) using an ILPH. Type of connection RS232 RS422 RS485 CL OF Ethernet Example : RS-232 Multipoint connections Some equipments are only designed to communicate in RS232 point to point connection. To communicate with several devices it is then necessary to use converters RS232 to RS422, RS485, CL or OF to reach multipoint mode. RS-485 Example : RS-232 Max. distances 1) 15 m 1.2km 1.2km 300-500m 4 km 100 m with CAT5 cable Depending on transmission speed Converter 15 m max. Repeater RS-422 RS-422 1.2 km max. 1.2 km max. 15 m max. RS-232 Example : "World Wide" communication Communication is more and more used with Ethernet support. The interests are to have a distant access, to use an already existing network and to upload information and data on a supervisor or a computer. The conversions from serial to Ethernet protocol are used to connect local network to Ethernet. Protocol conversion Modbus is one of the main protocols used in the industrial networks. The creation of Modbus/TCP allows an adapted access to the Ethernet network. So, the conversion between these 2 protocols is necessary. TCP RS-232 RS-485 Example : Modbus / TCP Modbus / RTU 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/4 Analog signal converters - CC-E range Product group picture 4 4/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Analog signal converters - CC-E range Table of contents Analog signal converters - CC-E range Benefits and advantages 4/7 Ordering details - Standard signal converters 4/8 Ordering details - RTD converters 4/9 Ordering details - Thermocouple converters 4/10 Ordering details - Measuring converters 4/11 DIP switch settings, Dimensional drawings 4/12 Wiring instructions 4/13 Technical data 4/14 Technical data 4/15 Technical data 4/16 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/6 4 Analog signal converters - CC-E range Benefits and advantages 1 1 Terminals M, K, J, H, G 2 Terminal explanation 3 Adjustment of gain 2 4 Adjustment of offset 4 Indication of operational states U - control supply voltage applied 3 4 4 5 CC-E range – – Universally configurable devices and single-function devices – – Adjustment and operating elements on the front side – – Safe operation by electrical 3-way isolation – – Unambiguous and clear connecting terminal markings 2 1 Conversion, measurement and separation of – – Standard signals (0-5 V, 0-10 V, 0-20 mA, 4-20 mA) – – Temperature signals of RTD sensors (PT 100) – – Thermocouple signals (types J and K) – – Current measurement signals (0-5 A, 0-20 A AC/DC) Characteristics of single-function devices – – No adjustment or balancing necessary. Characteristics of universal devices – – The required input and output ranges can be configured by means of directly accessible DIP switches positioned on the side – – Gain adjustment of ±5 % by means of an adjustment potentiometer on the front-side – – Offset adjustment of ±5 % by means of adjustment potentiometers on the front-side CC-E/STD analog signal converter with 3-way electrical isolation –– 2 universally configurable devices (type CC-E/STD) –– 2x10 single-function devices –– "Plug and Work", no adjustment of single-function devices required CC-E/RTD temperature signal converter for RTD sensors, linearized with 3-way electrical isolation – – 2 universally configurable devices (type CC-E/RTD) – – 2x12 single-function devices – – Plug and Work", no adjustment of single-function devices required – – Temperature signal converter for PT100 sensors – – 2- or 3-wire connection CC-E/TC analog signal converter for thermocouple signals of the types J and K with 3-way electrical isolation –– 2 universally configurable devices (type CC-E/TC) –– 2x6 single-function devices –– "Plug and Work", no adjustment of single-function devices required –– Integrated cold-junction compensation CC-E/I measuring converter for current signals 0-5 A, 0-20 A, AC/DC with 3-way electrical isolation – – 2 universally configurable devices (type CC-E/I) – – 2x6 single-function devices – – "Plug and Work", no adjustment of single-function devices required CC-E IAC/ILPO measuring converter without auxiliary power for sinusoidal currents 0-1 A, 0-5 A, output 4-20 mA –– Measuring converter for sinusoidal currents (0-1 A, 0-5 A) –– Measuring range selection by front-face sliding switch –– 4-20 mA output current in proportion to input current –– no additional power supply required Loop-powered current/current isolator without external power supply for analog current signals of 0-20 mA and 4-20 mA – – Electrical isolation between input and output – – Very low internal voltage drop 2.5 V – – Available with one or two independent channels – – Width only 18 mm (1 and 2 channels) 4/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Analog signal converters - CC-E range Ordering details - Standard signal converters Ordering details - Standard signal converters Supply voltage range Input signal 2CDC 281 010 F0003 CC-E/STD1) 1SVR011700R0000 0-10 V CC-E V/V 1SVR011710R2100 0-20 mA CC-E V/I 1SVR011711R1600 4-20 mA CC-E V/I 1SVR011712R1700 0-10 V CC-E I/V 1SVR011713R1000 0-20 mA CC-E I/I 1SVR011714R1100 4-20 mA CC-E I/I 1SVR011715R1200 0-10 V CC-E I/V 1SVR011716R1300 0-20 mA CC-E I/I 1SVR011717R1400 4-20 mA CC-E I/I 1SVR011718R2500 -10...+10 V -10...+10 V CC-E V/V 1SVR011719R2600 0-5 V, 0-10 V, 0-20 mA, 4-20 mA 0-5 V, 0-10 V, 0-20 mA, 4-20 mA CC-E/STD 1SVR011705R2100 0-10 V CC-E V/V 1SVR011720R2300 0-20 mA CC-E V/I 1SVR011721R1000 4-20 mA CC-E V/I 1SVR011722R1100 0-10 V CC-E V/V 1SVR011723R1200 0-20 mA CC-E I/I 1SVR011724R1300 4-20 mA CC-E I/I 1SVR011725R1400 0-10 V CC-E V/V 1SVR011726R1500 0-20 mA CC-E I/I 1SVR011727R1600 4-20 mA CC-E I/I 1SVR011728R2700 -10...+10 V -10...+10 V CC-E V/V 1SVR011729R2000 0-20 mA, 4-20 mA CC-E I/I-12) 1SVR010200R1600 0-20 mA, 4-20 mA CC-E I/I-22) 1SVR010201R0300 2CDC 281 001 F0003 0-20 mA 4-20 mA CC-E V/V 0-10 V 2CDC 281 041 F0003 Order code 0-5 V, 0-10 V, 0-20 mA, 4-20 mA 0-10 V 24 V DC Type 110-240 V AC 0-20 mA CC-E I/I-2 4-20 mA loop powered 1) 2) Price 1 pce 0-5 V, 0-10 V, 0-20 mA, 4-20 mA CC-E/I Output signal Weight (1 pce) kg (lb) 0.088 (0.194) 0.083 (0.183) 0.084 (0.185) 0.084 (0.187) 0.082 (0.181) 0.084 (0.187) 0.084 (0.185) 0.084 (0.185) 0.084 (0.187) 0.082 (0.181) 0.090 (0.198) 0.096 (0.212) 0.087 (0.192) 0.091 (0.200) 0.091 (0.200) 0.088 (0.194) 0.096 (0.212) 0.087 (0.192) 0.088 (0.194) 0.086 (0.190) 0.038 (0.084) 0.044 (0.097) B 1604 Class I, Div.2 (universal device) CC-E-I/I-1 has 1 channel, CC-E-I/I-2 has 2 channels 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/8 4 Analog signal converters - CC-E range Ordering details - RTD converters Ordering details - RTD converters Supply voltage range Input signal 2CDC 281 004 F0003 Type Order code Price 1 pce refer to table PT100 0...100 °C CC-E/RTD 4 PT100 -50...+50 °C 24 V DC PT100 0...300 °C PT100 -50...+250 °C refer to table PT100 0...100 °C PT100 -50...+50 °C 110-240 V AC PT100 0...300 °C PT100 -50...+250 °C 1) Output signal Weight (1 pce) kg (lb) 0-10 V, 0-20 mA, 4-20 mA CC-E/RTD1) 1SVR011701R2500 0.091 (0.200) 0-10 V CC-E RTD/V 1SVR011730R2500 0.084 (0.185) 0-20 mA CC-E RTD/I 1SVR011731R1200 4-20 mA CC-E RTD/I 1SVR011732R1300 0-10 V CC-E RTD/V 1SVR011733R1400 0.083 (0.183) 0-20 mA CC-E RTD/I 1SVR011734R1500 0.084 (0.185) 4-20 mA CC-E RTD/I 1SVR011735R1600 0.084 (0.187) 0-10 V CC-E RTD/V 1SVR011736R1700 0.084 (0.185) 0-20 mA CC-E RTD/I 1SVR011737R1000 0.084 (0.187) 4-20 mA CC-E RTD/I 1SVR011738R2100 0.101 0-10 V CC-E RTD/V 1SVR011739R2200 0.084 (0.185) 0-20 mA CC-E RTD/I 1SVR011740R0700 4-20 mA CC-E RTD/I 1SVR011741R2400 0-10 V, 0-20 mA, 4-20 mA CC-E/RTD 1SVR011706R2200 0.093 (0.205) 0-10 V CC-E RTD/V 1SVR011788R2400 0.086 (0.190) 0-20 mA CC-E RTD/I 1SVR011789R2500 0.088 (0.194) 4-20 mA CC-E RTD/I 1SVR011790R2200 0.089 (0.196) 0-10 V CC-E RTD/V 1SVR011791R1700 0.087 (0.192) 0-20 mA CC-E RTD/I 1SVR011792R1000 4-20 mA CC-E RTD/I 1SVR011793R1100 0-10 V CC-E RTD/V 1SVR011794R1200 0-20 mA CC-E RTD/I 1SVR011795R1300 4-20 mA CC-E RTD/I 1SVR011796R1400 0-10 V CC-E RTD/V 1SVR011797R1500 0.086 (0.190) 0-20 mA CC-E RTD/I 1SVR011798R2600 0.089 (0.196) 4-20 mA CC-E RTD/I 1SVR011799R2700 0.088 (0.194) B 1604 Class I, Div.2 (universal device) 4/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 0.086 (0.190) 0.084 (0.187) 0.089 (0.196) 0.087 (0.192) 0.089 (0.196) Analog signal converters - CC-E range Ordering details - Thermocouple converters Ordering details - Thermocouple Converters Supply voltage range type J 0...600 °C 24 V DC type K 0...1000 °C thermocouple types J and K type J 0...600 °C 110-240 V AC type K 0...1000 °C 1) Output signal Type Order code Price 1 pce thermocouple types J and K 2CDC 281 007 F0003 CC-E TC Input signal Weight (1 pce) kg (lb) 0-10 V, 0-20 mA, 4-20 mA CC-E/TC1) 1SVR011702R2600 0.089 (0.196) 0-10 V CC-E TC/V 1SVR011750R0100 0.087 (0.192) 0-20 mA CC-E TC/I 1SVR011751R2600 0.084 (0.187) 4-20 mA CC-E TC/I 1SVR011752R2700 0.102 0-10 V CC-E TC/V 1SVR011753R2000 0-20 mA CC-E TC/I 1SVR011754R2100 4-20 mA CC-E TC/I 1SVR011755R2200 0.086 (0.190) 0-10 V, 0-20 mA, 4-20 mA CC-E/TC 1SVR011707R2300 0.088 (0.194) 0-10 V CC-E TC/V 1SVR011760R0300 0.084 (0.187) 0-20 mA CC-E TC/I 1SVR011761R2000 0.088 (0.194) 4-20 mA CC-E TC/I 1SVR011762R2100 0.1 (0.220) 0-10 V CC-E TC/V 1SVR011763R2200 0.086 (0.190) 0-20 mA CC-E TC/I 1SVR011764R2300 0.088 (0.194) 4-20 mA CC-E TC/I 1SVR011765R2400 0.086 (0.190) 0.084 (0.185) B 1604 Class I, Div.2 (universal device) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/10 4 Analog signal converters - CC-E range Ordering details - Measuring converters Ordering details - Measuring Converters Supply voltage range 0-5 A, 0-20 A, AC 24 V DC 4 0-5 A, 0-20 A, DC 0-5 A, 0-20 A, AC/DC 110-240 V AC 0-5 A, 0-20 A, AC 0-5 A, 0-20 A, DC loop powered 1) 2) Output signal Type Order code Price 1 pce 0-5 A, 0-20 A, AC/DC 2CDC 281 018 F0004 CC-E IAC/ILPO Input signal 0-1 A, 0-5 A, AC Weight (1 pce) kg (lb) 0-10 V, 0-20 mA, 4-20 mA CC-E/I1) 1SVR011703R2700 0.096 (0.212) 0-10 V CC-E IAC/V 1SVR011770R0500 0.090 (0.198) 0-20 mA CC-E IAC/I 1SVR011771R2200 4-20 mA CC-E IAC/I 1SVR011772R2300 0-10 V CC-E I DC /V 1SVR011773R2400 0.092 (0.207) 0-20 mA CC-E IDC/I 1SVR011774R2500 0.091 (0.200) 4-20 mA CC-E IDC/I 1SVR011775R2600 0.093 (0.205) 0-10 V, 0-20 mA, 4-20 mA CC-E/I 1SVR011708R0400 0.099 (0.218) 0-10 V CC-E IAC/V 1SVR011780R1100 0.092 (0.203) 0-20 mA CC-E IAC/I 1SVR011781R0600 0.092 (0.207) 4-20 mA CC-E IAC/I 1SVR011782R0700 0.095 (0.209) 0-10 V CC-E I DC /V 1SVR011783R0000 0.093 (0.205) 0-20 mA CC-E I DC /I 1SVR011784R0100 4-20 mA CC-E I DC /I 1SVR011785R1100 4-20 mA CC-E IAC /ILPO2) 1SVR010203R0500 B 1604 Class I, Div.2 (universal device) for sinusoidal currents 4/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 0.092 (0.203) 0.095 (0.209) 0.052 (0.115) Analog signal converters - CC-E range DIP switch settings, Dimensional drawings 0...300 °C 0...500 °C Legend ON OFF -50...+50 °C -50...+250 °C -50...+450 °C Switch 1 2 3 4 5 6 0...10 V 0-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA High fail safe Low fail safe CC-E/TC TC-K: 0...1000 °C Output Switch 1 2 3 4 5 6 0...10 V 0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 2CDC 282 003 F0204 High fail safe Low fail safe Legend ON OFF no influence Input I - DC I - AC I - DC I - AC I - DC I - AC Output Switch 1 2 3 4 5 6 0...10 V 0...20 mA 4...20 mA Legend ON OFF Input range selection - CC-E/I Select input range by terminals Input range 5 A Connected lines Used terminals Terminal marking 2CDC 282 011 F0204 TC-J: 0...600 °C CC-E/I 2CDC 282 007 F0208 Input Legend ON OFF no influence 4 2CDC 282 003 F0204 4...20 mA 0...100 °C Output 2CDC 282 002 F0204 0...20 mA 0...5 V 0...10 V 0...20 mA 4...20 mA 0...5 V 0...10 V 0...20 mA 4...20 mA 0...5 V 0...10 V 0...20 mA 4...20 mA 0...5 V 0...10 V 0...20 mA 4...20 mA Input 2CDC 282 005 F0208 0...10 V Switch 1 2 3 4 5 6 7 8 2CDC 282 002 F0204 0...5 V Output 2CDC 282 001 F0204 Input CC-E/RTD 2CDC 282 006 F0208 CC-E/STD, CC-E x/x (universal devices) Input range 20 A Connected lines Used terminals Terminal marking Dimensional drawings 2CDC 282 011 F0b06 22.5 0,88 " 18 0.71" 2CDC 282 012 F0b06 CC-E IAC/ILPO, CC-E I/I CC-E/x 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/12 Analog signal converters - CC-E range Wiring instructions CC-E/STD, CC-E x/x (universal devices) CC-E/RTD G supply Burden R 1.0 k H Burden R 500 J supply 2CDC 282 007 F0206 Burden R 500 2CDC 282 006 F0206 Burden R 1.0 k 4 CC-E IAC/ILPO CC-E/TC supply CC-E I/I-2 Channel 1 Channel 1 input 0-20 mA or 4-20 mA output 0-20 mA or 4-20 mA input 0-20 mA or 4-20 mA IN C F D E OUT UL IN OUT RL 500 2CDC 282 003 F0205 Channel 1 Channel 1 IN C F D E OUT output 0-20 mA or 4-20 mA UL IN OUT RL 500 Channel 2 input 0-20 mA or 4-20 mA Chanel 2 IN A H B G OUT output 0-20 mA or 4-20 mA UL IN OUT RL 500 CC-E I/I I 5A H V J IN OUT I G K - M supply + A + C - D + F - Burden R 1.0 k Burden R 500 2CDC 282 008 F0208 20 A 4/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 2CDC 282 004 F0205 CC-E I/I-1 2CDC 282 010 F0b06 Burden R 500 2CDC 282 008 F0206 Burden R 1.0 k Analog signal converters - CC-E range Technical data Type Input circuits - Analog inputs J-G-H CC-E/STD / CC-E x/x Current Voltage CC-E/RTD 3) Temperature sensors (IEC 584-1 and 2) Standard signals PT100 TC.K, TC.J 0...20 mA / 0...5 V / -50...+500 °C TC.K: 0...1000 °C, 4...20 mA 0...10 V / TC.J: 0...600 °C -10...+10 V +55 mA ± 11 V < 0.01 %/ < 0.5 % / 100 ± 5 % (universal devices) ± 5 % (universal devices) 50 1 M > 35 dB 100 dB D-F, A-C Current Voltage 0-20 mA, 4-20 mA 0-5 V, 0-10 V 500 1.0 K ± 0.5 % of full-scale < 0.5 % 200 µs 10 ms 2 kHz 80 Hz 2 Hz (up to -3 dB) High fail safe: Output voltage > 115 % of measuring range 2) Low fail safe: Output voltage < -0.6 V, output current = 0 mA K-M DC versions AC versions 24 V DC 110-240 V AC - 50/60 Hz -15...+15 % -15...+10 % 1.5 W typ. 1.5 VA typ. Input signal Rated input range Limitation of input signals Influence of line resistance Gain adjustment range Offset adjustment range Input impedance Suppression at 50 Hz Common-mode rejection Output circuits - Analog outputs Output signal Output burden Accuracy 1) Residual ripple Response time Transmission frequency Reaction to input circuit interruption Supply circuits Supply voltage Supply voltage tolerance Power consumption Indication of operational states Rated control supply voltage U S U: green LED General data Ambient temperature range operation / storage Temperature coefficient Degree of protection (DIN 40050) Mounting position 0...+60 °C / -20...+80 °C ± 500 ppm/°C IP20 ventilation slots on top and bottom Mounting DIN rail (IEC/EN 60715), snap-on mounting Electrical connection Wire size rigid 0.2-4 mm 2 (24-12 AWG) fine-strand with(out) wire end ferrule 0.2-2.5 mm 2 (24-14 AWG) 7 mm (0.28 inch) 0.5 Nm (4.4 lb.in) Stripping length Tightening torque Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) electromagnetic field(HF radiation resistance) fast transients (Burst) powerful impulses (Surge) HF line emission Interference emission Isolation data Test voltage between all isolated circuits Rated insulation voltage 1) 2) 3) CC-E/TC Thermocouples EN 61000-6-2 IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV) IEC/EN 61000-4-3 10 V/m IEC/EN IEC/EN IEC/EN EN 61000-4-4 61000-4-5 61000-4-6 61000-6-4 Level 3 (±2 kV / 5 kH) ±2 kV / ±1 kV 10 V Class B 2.5 kV AC - - - Includes non-linearity and factory setting, influenced by supply voltage and output load. Only -/RTD and -/TC: Single-function devices respond with Low fail safe to input signal interruptions. When connecting a 2-wire sensor, the terminals J and H have to be jumpered. Approvals on page 4/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/14 4 Analog signal converters - CC-E range Technical data Type CC-E I/I-1 / CC-E I/I-2 Current Input circuits - Analog inputs Input current I IN 0-20 mA, 4-20 mA Min. input current Max. input current Input voltage U IN < 100 µA 50 mA1) (V IN < 18 V) Input voltage drop U i < 2.5 V (20 mA, RL = 0 ) 18 V1) (I IN < 50 mA) < 2.5 V + (I IN x R L) Max. input voltage Output circuits Output current I OUT 4 0-20 mA, 4-20 mA 0-500 I OUT x RL Output load R L Output voltage U OUT Residual ripple < 20 mVpp (500 , 20 mA) < 15 ms (0-500 , 20 mA), < 5 ms (500 , 20 mA, 25 °C) 0.1 % of full-scale (20 mA) 0.05 % / 100 , -0.1 % / 100 (25 °C) Response time (0-100 %) Accuracy Load influence (0-500 ) General data Width of the enclosure Weight Mounting position Degree of protection Ambient temperature range Temperature coefficient Mounting Electrical connection Wire size Stripping length Tightening torque Standards Product standard Low Voltage Directive EMC Directive Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) electromagnetic field (HF radiation resistance) fast transients (Burst) powerful impulses (Surge) HF line emission magnetic fields Interference emission Radiated noise Operational reliability (EN 68-2-6) Mechanical resistance (EN 68-2-6) Environmental testing (IEC 68-2-30 Db) Isolation data Insulation voltage input / output Insulation voltage between channels Pollution category Overvoltage category 1) 18 mm 1 channel approx. 0.037 kg (0.082 (0.181) lb) 2 channel approx. 0.044 (0.097) kg (0.097 lb) any enclosure / terminals IP20 / IP20 operation / storage -25...+60 °C / -40...+85 °C < 50 ppm / °C DIN rail (IEC/EN 60715) rigid 0.2-4 mm 2 (24-12 AWG) fine-strand with(out) wire end ferrule 0.2-2.5 mm 2 (24-14 AWG) 7 mm (0,28 inch) 0.5 Nm (4.4 lb.in) EN 50178 2006/95/EC 2004/108/EC EN 61000-6-2 EN 61000-4-2 Level 3 (±6 kV / ±8 kV) EN 61000-4-3 10 V/m EN EN EN EN 61000-4-4 61000-4-5 61000-4-6 61000-4-8 Level 3 (±2 kV / 5 kH) ±2 kV / ±1 kV 10 V 30 A/m EN 61000-6-4 EN 55011 Class B 4g 10 g 24 h cycle, 55 °C, 93 % rel., 96 h The input parameters have to be limited to the indicated maximum values. Approvals on page 4/4. 4/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 500 Veff / 50 Hz 5 kVeff / 50 Hz (device with 2 channels) 2 II Analog signal converters - CC-E range Technical data Type Input circuits - Analog inputs Rated input range Measuring frequency Overload capacity of inputs Gain adjustment range Offset adjustment range Input impedance / resistance Output circuits - Analog outputs AC current 0-5 A / 0-20 A Output burden / load Supply circuits Supply voltage CC-E IAC/ILPO C-D 2 meas. ranges selectable 0-1 A / 0-5 A / sinusoidal 50/60 Hz 10 x I Nom (50 A) for max. 2 s 10 x I Nom (200 A) for max. 2 s 5 m F-E passive current output in proportion to input current 0-20 mA / 4-20 mA 0-10 V 4-20 mA 500 1.0 12 V DC: 150 , 24 V DC: 750 30 V DC: 1050 ± 2 % of full-scale ±5 % (universal device) ±5 % (universal device) < 0.5 % 0.5 s DC or 50/60 Hz Low fail safe: output voltage < 200 mV, output current < 400 µA K-M DC versions AC versions 110-240 V AC 24 V DC 50/60 Hz -15...+15 % -15...+10 % typ 1.5 W typ 1.5 VA Supply voltage tolerance Power consumption Indication of operational states Supply voltage General data Ambient temperature range operation / storage Temperature coefficient Degree of protection (DIN 40050) Mounting position Mounting Electrical connection Wire size rigid fine-strand with(out) wire end ferrule Stripping length Tightening torque Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) IEC/EN 61000-4-2 electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 fast transients (Burst) IEC/EN 61000-4-4 powerful impulses (Surge) IEC/EN 61000-4-5 HF line emission IEC/EN 61000-4-6 Interference emission EN 61000-6-4 Isolation data Test voltage (between all isolated circuits) Rated insulation voltage 1) DC current 0-5 A / 0-20 A input range 1 10 x I (50 A) for max. 1 s Nom input range 2 10 x I (200 A) for max. 1 s Nom ±5 % (universal devices) ±5 % (universal devices) 5A : 65 m 20 A : 2.5 m D-F Current A-C Voltage Output signal Accuracy 1) Offset adjustment range Gain adjustment range Residual ripple Response time Transmission frequency Reaction to input circuit interruption CC-E/I J-G-H U: green LED ±5% ± 20 % 0.6 s AC: 50/60 Hz 12-30 V DC - 0...+60 °C / -20...+80 °C -20...+60 °C / -40...+80 °C ± 500 ppm/°C 300 ppm/°C IP20 ventilation slots on top and bottom DIN rail (IEC/EN 60715), snap-on mounting 0.2-4 mm² (24-12 AWG) 0.2-2.5 mm² (24-14 AWG) 7 mm (0.28 inch) 0.5 Nm (4.4 lb.in) EN 61000-6-2 Level 3 (±6 kV / ±8 kV) 10 V/m Level 3 (±2 kV / 5 kH) ±2 kV / ±1 kV 10 V Class B 2.5 kV AC - 250 V AC Includes non-linearity and factory setting, influenced by supply voltage and output load. Approvals on page 4/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/16 4 Analog signal converters - CC-U range Product group picture 4 4/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Analog signal converters - CC-U range Table of contents Analog signal converters - CC-U range Overview 4/19 Ordering details 4/21 Ordering details - Accessories 4/22 DIP switch settings 4/23 Wiring instructions 4/25 Technical information 4/26 Technical data 4/29 Technical diagr., Connection diagr., Dimensional drawings 4/32 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/18 4 Analog signal converters - CC-U range Overview 4 CC-U range – – 8 different standard signal outputs on one device – – Input and output side universally configurable – – Also available with 2 threshold relay outputs – – Adjustment and operating elements on the front side – – Safe operation by electrical 3-way isolation – – Plug-in connecting terminals, unambiguously and clearly m arked Conversion, measurement and separation of – – Standard signals – – Signals of RTD sensors (PT10, PT100, PT1000) – – Thermocouple signals – – TRMS values of currents and voltages Characteristics – – The required input and output ranges can be configured for all devices by means of directly accessible DIP switches positioned on the side. – – Due to the wide input range of the gain and offset stages all input signals between the minimum and the maximum input value can be universally converted to all common output signals. – – Devices for DC or AC (50/60 Hz) supply available. 1 Terminals +, V/I+, V/I-, PW DC, IN, 2 Terminal explanation 3 Adjustment of resistance value R1 1 4 Adjustment of hysteresis 4 Adjustment of resistance value R2 Adjustment of hysteresis 2 3 7 Indication of operational states R1 yellow LED - resistance value R1 R2 yellow LED - resistance value R2 U green LED - supply voltage 8 Marker label 4 5 7 8 2 1 4/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Analog signal converters - CC-U range Overview CC-U/STD universal signal converter with 3-way electrical isolation –– More than 120 configurations possible –– Configurable output signal response on input voltage signal interruption (low fail safe / high fail safe) –– Adjustment and operating elements on the front –– Short-circuit proof signal outputs –– Plug-i connecting terminals for inputs, outputs and supply –– Very fast signal transmission enables use in control systems CC-U/RTD universal signal converter for PT10, PT100, PT1000 temperature sensors (acc. to IEC 751 and JIS C 16041), linearized with 3-way electrical isolation) –– Configurable output signal response on input signal interruption (low / high fail safe) –– Adjustment and operating elements on the front-side –– Short-circuit proof signal outputs –– Plug-in connecting terminals for inputs, outputs and supply –– 2- or 3-wire connection 1) Japanese standard CC-U/STDR universal signal converter for standard signals, with 2 threshold relay outputs and with 3-way electrical isolation – – Standard signal converter with 7 setting ranges – – 2 threshold relay outputs with one c/o contact each (threshold and respective hysteresis can be adjusted independently from each other) – – Open-circuit or closed-circuit principle configurable by means of a DIP switch – – 2 yellow LEDs for clear status indication of the output relays – – Plug-in connecting terminals for inputs, outputs and supply CC-U/RTDR universal signal converter for temperature and resistance signals, with 2 threshold relay outputs and 3-way electrical isolation – – Temperature signal converter for PT100 signals (5 ranges up to 800 °C) and variable resistances from 0-380 q – – 2 threshold relay outputs with one c/o contact each (threshold and respective hysteresis can be adjusted independently from each other) – – Open-circuit or closed-circuit principle configurable by means of a DIP switch – – 2 yellow LEDs for clear status indication of the output relays – – Plug-in connecting terminals for inputs, outputs and supply – – 2- or 3-wire connection CC-U/TC universal signal converter for thermocouples with 3-way electrical isolation –– Temperature signal converter for thermo-couples of the types K, J, T, S, E, N, R, B –– Continuously adjustable voltage signal input 0-10 mV and 0-50 mV –– Differential temperature meas. possible (see wiring instructions page 4/17) –– Configurable output signal response on input signal interruption (low fail safe / high fail safe) –– Adjustment and operating elements on the front-side –– Short-circuit proof signal outputs –– Plug-in connecting terminals for inputs, outputs and supply –– Cold-junction compensation selectable CC-U/TCR universal signal converter for thermocouples, with 2 threshold relay outputs and 3-way electrical isolation – – Temperature signal converter for thermocouples of the types K, J, T, S – – 2 threshold relay outputs with one change-over contact each (threshold and respective hysteresis can be adjusted independently from each other) – – Open-circuit or closed-circuit principle configurable by means of a DIP switch – – 2 yellow LEDs for clear status indication of the output relays – – Plug-in connecting terminals for inputs, outputs and supply – – Integrated cold-junction compensation CC-U/V universal measuring converter for RMS values of 0-600 V, with 3-way electrical isolation –– RMS converter for voltage signals up to 600 V of any wave form (DC, DC with superimposed AC components, pure sinusoidal, triangular, phase-angle controlled, etc. in a measuring range of 0-600 Hz) –– Adjustment and operating elements on the front –– Short-circuit proof signal outputs –– Plug-in connecting terminals for inputs, outputs and supply CC-U/I universal measuring converter for RMS values of 0-1 A and 0-5 A, with 3-way electrical isolation – – RMS converter for current signals up to 1 A and up to 5 A of any wave form (DC, DC with superimposed AC components, pure sinusoidal, triangular, phase-angle controlled, etc. in a measuring range of 0-600 Hz) – – Adjustment and operating elements on the front – – Short-circuit proof signal outputs – – Plug-in connecting terminals for inputs, outputs and supply 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/20 4 Analog signal converters - CC-U range Ordering details Ordering details - Standard Signal Converters 2CDC 281 003 F0003 Supply voltage range Output signal Type Order code Price 1 pce 0.125 (0.276) 0.126 (0.278) 1SVR040000R1700 refer to table CC-U/STD 1SVR040001R0400 refer to table 2 c/o CC-U/ STDR1) Weight (1 pce) kg (lb) 1SVR040010R0000 0.142 (0.313) 1SVR040011R2500 CC-U/STDR Ordering details - RTD Converters Supply voltage range Input signal 2CDC 281 005 F0003 CC-U/RTD 110-240 V AC, 100-300 V DC 24-48 V DC, 24 V AC Output signal Type Order code Price 1 pce 24-48 V DC, 24 V AC refer to table 1SVR040002R0500 0.126 (0.278) 1SVR040003R0600 0.128 (0.282) 1SVR040012R2600 0.146 (0.322) 1SVR040013R2700 0.148 (0.326) CC-U/RTD refer to table 2 c/o 110-240 V AC, 100-300 V DC Weight (1 pce) kg (lb) CC-U/RTDR1) Ordering details - Thermocouple Converters Supply voltage range Input signal 2CDC 281 008 F0003 CC-U/TC 110-240 V AC, 100-300 V DC 24-48 V DC, 24 V AC Output signal Type Order code Price 1 pce 24-48 V DC, 24 V AC refer to table 1SVR040004R0700 0.130 (0.287) 1SVR040005R0000 0.128 (0.282) CC-U/TC refer to table 1SVR040014R2000 2 c/o 110-240 V AC, 100-300 V DC Weight (1 pce) kg (lb) 0.145 (0.320) CC-U/TCR1) 1SVR040015R2100 Ordering details - Measuring Converters Supply voltage range Input signal Output signal CC-U/I 110-240 V AC, 100-300 V DC 24-48 V DC, 24 V AC 2) 3) Order code Price refer to table 0.128 (0.282) 1SVR040007R0200 0.127 (0.280) refer to table with relay output for current RMS values for voltage RMS values 4/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Weight (1 pce) kg (lb) 1SVR040006R0100 CC-U/I2) 110-240 V AC, 100-300 V DC 1) Type 1 pce 24-48 V DC, 24 V AC 2CDC 281 012 F0003 4 24-48 V DC, 24 V AC 110-240 V AC, 100-300 V DC 24-48 V DC, 24 V AC 110-240 V AC, 100-300 V DC Input signal 1SVR040008R1300 CC-U/V3) 1SVR040009R1400 0.128 (0.282) 10 .394” 22,5 .886” 62,5 2.46” 2CDC 252 187 F0005 4,5 .177” 11,5 .453” Analog signal converters - CC-U range Ordering details - Accessories Ordering details - Accessories For type CC-U 60 2.36” ADP.01 Width in mm Type Order code 22.5 ADP.01 1SVR430029R0100 1 18.4 (0.65) MAR.01 1SVR366017R0100 10 0.19 (0.007) COV.01 1SVR430005R0100 1 5.2 (0.18) MAR.01 7 .275” 3,5 .138” 68,5 2.70 ” 22,5 .886” 22.5 Pkg qty Weight (1 pce) g (oz) 4 2CDC 252 185 F0005 20 .787” CC-U 2CDC 252 186 F0005 3A11 8 .315” CC-U Price front-to-back size 107 Sealable cover - COV.01 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/22 Analog signal converters - CC-U range DIP switch settings Input Switch 1 Switch 2 Range 1 2 3 4 5 6 1 2 3 4 5 6 0...500 °C 0...550 °C 0...600 °C 0...650 °C PT10 0...700 °C 0...750 °C 0...800 °C 0...850 °C 0...50 °C 0...60 °C 0...70 °C 0...80 °C 0...90 °C PT100 0...100 °C 0...200 °C 0...300 °C 0...400 °C 0...500 °C 0...10 °C 0...20 °C 0...30 °C PT1000 0...40 °C 0...50 °C 0...60 °C Low fail safe *) High fail safe *) Type CC-U/RTDR with relay output Output Closed-circuit principle Open-circuit principle Switch 1 2 3 4 5 6 Legend ON OFF no influence 2CDC 282 003 F0204 0...100 °C 0...200 °C 0...400 °C 0...600 °C 0...800 °C Legend ON OFF no influence CC-U/RTD Output Input PT100 2CDC 282 005 F0204 Output Closed-circuit principle Open-circuit principle 4/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 0...5 V 0...10 V 1...5 V 2...10 V -10...+10 V -5...+5 V -10...0 V -5...0 V 0...6.66 V -10...+3.33 V -5...+1.66 V 0...8 V 0...4 V -10...-2 V -5...-1 V 1.25...6.25 V -7.5...+2.5 V -3.75...+1.25 V 1.66...8.33 V -6.66...+6.66 V -3.33...+3.33 V -8...0 V -4...0 V 0...1 mA 0...20 mA 4...20 mA 0...10 mA 0...0.5 mA 0...13.33 mA 0...666 µA 0...16 mA 0...800 µA 0...8 mA 0...400 µA 2.5...12.5 mA 125...625 µA 3.33...16.66 mA 166...833 µA 0.2...1 mA 2...10 mA 100...500 µA Switch 3 1 2 3 4 5 6 Legend ON OFF no influence Gain Coarse F E D C B A 9 8 F E B A 9 8 3 2 1 0 8 3 2 1 0 0 - *) Detection of input signal interruptions: If the input signal circuit is interrupted, the output signal changes to the adjusted minimum value (low fail safe) or maximum value (high fail safe). 2CDC 282 023 F0203 Legend ON OFF no influence Switch 1 2 3 4 5 6 2CDC 282 003 F0204 *) Detection of input voltage signal interruptions: If the input signal circuit is interrupted, the output signal changes to the adjusted minimum value (low fail safe) or maximum value (high fail safe). If "No fail safe" is configured, input signal interruptions are not detected. Input 0...10 V 0...5 V 0...1 V -10...+10 V 1...5 V 0...20 mA 4...20 mA 0...5 V 0...10 V 1...5 V 2...10 V -10...+10 V -5...+5 V -10...0 V -5...0 V 0...6.66 V -10...+3.33 V -5...+1.66 V 0...8 V 0...4 V -10...-2 V -5...-1 V 1.25...6.25 V -7.5...+2.5 V -3.75...+1.25 V 1.66...8.33 V -6.66...+6.66 V -3.33...+3.33 V -8...0 V -4...0 V 0...1 mA 0...20 mA 4...20 mA 0...10 mA 0...0.5 mA 0...13.33 mA 0...666 µA 0...16 mA 0...800 µA 0...8 mA 0...400 µA 2.5...12.5 mA 125...625 µA 3.33...16.66 mA 166...833 µA 0.2...1 mA 2...10 mA 100...500 µA 2CDC 282 024 F0203 0 A...D 4...5 0...1 7...9 3...4 0 5...7 2 7...9 2...4 0 3...4 3...4 B...F 0 5...7 3...4 2 4...5 A...D 2...4 4...5 0...1 4...5 4...2 B...F 4...6 - Switch 2 1 2 3 4 5 6 Output 2CDC 282 020 F0203 Potentiometer 0...50 mV 0...100 mV 0...250 mV 0...500 mV 0...1 V 0...2.5 V 0...5 V 0...10 V 1...5 V 2... 10 V -10...+10 V 0...125 mV 0...8 V -22.5...+22.5 mV -11...+11 V 2.5...7.5 V 3.33...9.99 V 10...0 V 100...0 mV 0...1 mA 0...20 mA 4...20 mA 10...50 mA 20...4 mA 20...0 mA -0.45...+0.45 mA -55...+55 mA High fail safe *) Low faile safe *) No fail safe *) Coarse Type 0 C 5 1 8 3 0 6 2 8 3 0 3 3 D 0 6 4 2 5 B 3 4 1 4 3 D 5 - 2CDC 282 003 F0204 Gain 2CDC 282 007 F0204 4 Switch 1 1 2 3 4 5 6 7 8 2CDC 282 019 F0203 Input CC-U/STDR with relay output 2CDC 282 003 F0204 CC-U/STD Analog signal converters - CC-U range DIP switch settings 2CDC 282 029 F0203 Legend ON OFF no influence Type *) Detection of input signal interruptions: If the input signal circuit is interrupted, the output signal changes to the adjusted minimum value (low fail safe) or maximum value (high fail safe). Legend ON OFF no influence 0...5 V 0...10 V 1...5 V 2...10 V -10...+10 V -5...+5 V -10...0 V -5...0 V 0...6.66 V -10...+3.33 V -5...+1.66 V 0...8 V 0...4 V -10...-2 V -5...-1 V 1.25...6.25 V -7.5...+2.5 V -3.75...+1.25 V 1.66...8.33 V -6.66...+6.66 V -3.33...+3.33 V -8...0 V -4...0 V 0...1 mA 0...20 mA 4...20 mA 0...10 mA 0...0.5 mA 0...13.33 mA 0...666 µA 0...16 mA 0...800 µA 0...8 mA 0...400 µA 2.5...12.5 mA 125...625 µA 3.33...16.66 mA 166...833 µA 0.2...1 mA 2...10 mA 100...500 µA J K T S Input Switch Range 1 2 3 4 5 6 0...240 °C 0...480 °C 0...1200 °C 0...250 °C 0...500 °C 0...1350 °C -150...+120 °C 0...220 °C 0...400 °C 0...210 °C 0...380 °C 0...860 °C 0...1550 °C Output Closed-circuit principle Open-circuit principle Legend ON OFF no influence 2CDC 282 003 F0204 2CDC 282 029 F0203 Legend ON OFF no influence 2CDC 282 003 F0204 Type Switch 1 2 3 4 5 6 2CDC 282 004 F0204 CC-U/TCR with relay output CC-U/I Output Input Switch 1 Switch 2 Range 1 2 3 4 5 6 1 2 3 4 5 6 0-100...900 °C K 0-250...1350 °C J 0-100...750 °C 0-100...400 °C T -150-0...400 °C S 0-250...1550 °C 0-100...700 °C E 0-200...1000 °C 0-100...650 °C N 0-200...1300 °C 0-250...1350 °C R 0-450...1700 °C B 0-700...1750 °C 0-2...10 mV mV 0-10...50 mV Low fail safe *) High fail safe *) Switch 3 1 2 3 4 5 6 0...5 V 0...10 V 1...5 V 2...10 V -10...+10 V -5...+5 V -10...0 V -5...0 V 0...6.66 V -10...+3.33 V -5...+1.66 V 0...8 V 0...4 V -10...-2 V -5...-1 V 1.25...6.25 V -7.5...+2.5 V -3.75...+1.25 V 1.66...8.33 V -6.66...+6.66 V -3.33...+3.33 V -8...0 V -4...0 V 0...1 mA 0...20 mA 4...20 mA 0...10 mA 0...0.5 mA 0...13.33 mA 0...666 µA 0...16 mA 0...800 µA 0...8 mA 0...400 µA 2.5...12.5 mA 125...625 µA 3.33...16.66 mA 166...833 µA 0.2...1 mA 2...10 mA 100...500 µA 2CDC 282 010 F0204 Output 2CDC 282 003 F0204 Switch 1 2 3 4 5 6 0...5 V 0...10 V 1...5 V 2...10 V -10...+10 V -5...+5 V -10...0 V -5...0 V 0...6.66 V -10...+3.33 V -5...+1.66 V 0...8 V 0...4 V -10...-2 V -5...-1 V 1.25...6.25 V -7.5...+2.5 V -3.75...+1.25 V 1.66...8.33 V -6.66...+6.66 V -3.33...+3.33 V -8...0 V -4...0 V 0...1 mA 0...20 mA 4...20 mA 0...10 mA 0...0.5 mA 0...13.33 mA 0...666 µA 0...16 mA 0...800 µA 0...8 mA 0...400 µA 2.5...12.5 mA 125...625 µA 3.33...16.66 mA 166...833 µA 0.2...1 mA 2...10 mA 100...500 µA 2CDC 282 003 F0204 Output CC-U/TC 2CDC 282 017 F0208 CC-U/V 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/24 4 Analog signal converters - CC-U range Wiring instructions CC-U/STD CC-U/STDR with relay output G Pot. H Burden R 600 Value R1 supply Threshold Hysteresis 2CDC 282 016 F0206 J Burden R 4.7 k 2CDC 282 015 F0206 Value R2 4 supply CC-U/RTD CC-U/RTDR with relay output G Value R1 Burden R 600 H supply G υ J Threshold R1 E (12) F (11) D (14) R2 B (22) C (21) A (24) Hysteresis H Value R2 K M supply CC-U/V 2CDC 282 045 F0203 J 2CDC 282 017 F0206 Burden R 4.7 k CC-U/I Burden R 4.7 k Burden R 4.7 k supply Burden R 600 2CDC 282 022 F0206 Burden R 600 CC-U/TC supply 2CDC 282 021 F0206 + 2.5 V CC-U/TCR with relay output Value R1 supply Threshold Hysteresis Value R2 without cold-junction compensation: switch SW2.2 = OFF 2CDC 282 019 F0206 supply 4/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 2CDC 282 020 F0206 Burden R 600 2CDC 282 018 F0206 Burden R 4.7 k Analog signal converters - CC-U range Technical information CC-U/STD Adjustment range OUT [%] 100 Gain “gain-coarse” and “gain-fine” 90 80 70 60 50 40 30 4 20 10 IN [%] 10 20 30 40 50 60 70 80 90 100 Offset remote poti SW1.4 = +100 % SW1.5 = +50 % 2CDC 282 018 F0203 SW1.6 = +22.5 % CC-U/STDR with relay output Function diagrams Switching points Closed-circuit principle Switching points of the output relay depending on the input range, configuration open-circuit principle R1 Threshold value R1 Hysteresis IN [%] Input 11-14 R1 11-12 21-24 R2 21-22 va lu e 100 tu al 90 Threshold value R1 2-100 % of input range Ac R2 Threshold value 2CDC 282 044 F0203 R2 Hysteresis 80 Hysteresis R1 5-50 % of threshold value R1 70 60 Open-circuit principle 50 R1 Threshold value R1 Hysteresis 40 Threshold value R2 2-100 % of input range R2 Threshold value 11-14 R1 11-12 21-24 R2 21-22 2CDC 282 046 F0203 R2 Hysteresis 30 20 Hysteresis R2 5-50 % of threshold value R2 10 0 R1 11-14 11-12 R2 21-24 21-22 OUT 2CDC 282 021 F0203 Input 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/26 Analog signal converters - CC-U range Technical information CC-U/RTD Characteristic curves Resistance of PT10, PT100 and PT1000 sensors depending on the temperature PT100 2CDC 282 022 F0203 PT10 Temperature [°C] CC-U/RTDR with relay output Switching points Function diagrams Switching points of the output relay depending on the input range, configuration open-circuit principle IN [%] Closed-circuit principle R1 Threshold value R1 Hysteresis 100 Input va lu e tu 600 500 Ac Threshold value R1 2-100 % of input range 80 R2 Threshold value Hysteresis R1 5-50 % of threshold value R1 70 60 11-14 R1 11-12 21-24 R2 21-22 50 400 300 Threshold value R2 2-100 % of input range 200 40 30 20 100 Open-circuit principle R1 Threshold value Hysteresis R2 5-50 % of threshold value R2 R1 Hysteresis Input 10 R2 Hysteresis 100 150 200 250 300 350 Resistance [] OUT 400 R1 11-14 11-12 R2 21-24 21-22 R2 Threshold value 2CDC 282 025 F0203 0 50 2CDC 282 044 F0203 R2 Hysteresis al 90 700 2CDC 282 046 F0203 800 Temperature υ [°C] 11-14 R1 11-12 21-24 R2 21-22 CC-U/V Input range selection Switch position 1 2 3 4 5 6 7 8 RMS measurement and conversion of a phase-angle controlled voltage signal L1 = 230 V INUeff [V] U(t) [V] 300 resulting RMS value Gain 15 % OUT [%] 0 0 Offset 20 % -300 operating angle 4/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 50 100 2CDC 282 030 F0203 Selecting input range by front-face rotary switch 0...100 V 0...150 V 0...250 V 0...300 V 0...400 V 0...450 V 0...550 V 0...600 V Example of application 2CDC 282 012 F0204 4 Resistance [] PT1000 Analog signal converters - CC-U range Technical information CC-U/I Input range selection Example of application RMS measurement and conversion of a current signal IN [%] Select input range by terminals Gain 15 % Input range 1 A J H 5A I(t) [A] G 1A C Input range 5 A Connected lines Used terminals Terminal marking J H 5A G 1A 5 2CDC 282 033 F0203 Connected lines Used terminals Terminal marking C 4 3 2 resulting RMS value 1 0 t -1 0 50 4 OUT [%] 100 -2 2CDC 282 028 F0203 Offset 20 % -3 -4 -5 CC-U/TC Characteristic curve Thermocouple voltages depending on the temperature 80000 Typ E 75000 Typ J 70000 65000 60000 Typ K 55000 50000 Typ N Thermoelement-Spannung [µV] 45000 40000 35000 30000 25000 Typ R Typ T 20000 Typ S 15000 10000 Typ B 5000 0 -10000 1800 1750 1700 1650 1600 1550 1500 1450 1400 1350 1300 1250 1200 1150 1100 1050 950 900 850 1000 800 750 700 650 600 550 500 450 400 350 300 250 200 150 0 50 100 -50 -100 -150 -200 -250 -15000 Temperatur [°C] 2CDC 282 026 F0103 -5000 CC-U/TCR with relay output Function diagrams Switching points Switching points of the output relay depending on the input range, configuration open-circuit principle Closed-circuit principle R1 Threshold value R1 Hysteresis IN [%] Input Typ K Release hysteresis 4500 4000 3500 Threshold value R2 = 400 °C 3000 2500 Typ T Release hysteresis 2000 1500 Typ S 1000 500 R1 R2 21-24 21-22 1825 1725 1625 1525 1425 1325 1225 925 1125 825 Temperature [°C] 1025 725 625 525 425 325 225 25 -1500 11-14 11-12 OUT 2CDC 282 027 F0203 0 0 -500 -1000 -75 11-14 R1 11-12 21-24 R2 21-22 2CDC 282 046 F0203 R2 Threshold value 5000 125 Input R2 Hysteresis 5500 -175 R1 Threshold value R1 Hysteresis 6000 -275 Open-circuit principle Threshold value R1 = 1000 °C Typ J 6500 Thermocouple voltage [µV] 11-14 R1 11-12 21-24 R2 21-22 2CDC 282 044 F0203 R2 Threshold value 100 7000 R2 Hysteresis 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/28 Analog signal converters - CC-U range Technical data Type CC-U/STD Input circuits - Analog inputs J-G-H Current meter 0-100 mV 470 0-1 V -1 M 2) 0-5 V 1-5 V 0-10 V 2-10 V ± 10 V ± 55 mA ± 11 V 0-20 mA 4-20 mA 10-50 mA 0-1 mA Input signal Limitation of input signals Rated input range 4 Influence of line resistance Gain adjustment range (universal devices) Offset adjustment range (universal devices) Input impedance without detection of input signal interruption with detection of input signal interruption Suppression at 50 Hz Common-mode rejection Output circuits - Analog outputs Output signal 0.945 mV - 110 mA 22 V -137.5...+62.5 % for different ranges 51 6 M 3 G 51 3.5 M 9.5 G Current D-F, A-C 0-20 mA, 4-20 mA 600 ±0.1 % of full-scale 200 µs 1 kHz DC versions K-M 24-48 V DC 24-48 V DC / 24 V AC DC: -15...+15 % 0 Hz or 50/60 Hz 2 W at 24 V DC Output burden Accuracy 1) Residual ripple Response time Transmission frequency Supply circuits Rated supply voltage Supply voltage range Supply voltage tolerance Rated frequency Power consumption Indication of operational states Supply voltage General data Ambient temperature range operation / storage Temperature coefficient Mounting position Mounting Electrical connection Wire size 3) (IEC 584-1 and 2) TC.K TC.J TC.T TC.S TC.E TC.N TC.R TC.B Max. temperature refer to adjustable: temperature 6-60 °C for PT1000 specs. of individual 50-500 °C for PT100 thermocouples 500-850 °C for PT10 0.015 °C/ < 0.01 % / 100 see DIP switch settings ±5% 120 dB ± 10 % > 40 dB 105 dB Voltage 0-5 V, 1-5 V, 0-10 V, 2-10 V, ± 10 V 4.7 K ±0.2 % of full-scale ±0.1 % of full-scale < 0.15 % 10 ms 200 ms 80 Hz 2 Hz (to -3 dB) AC versions 110-240 V AC 110-240 V AC / 100-300 V DC AC: -15...+10 % 4.5 VA at 230 V AC U: green LED -20...+60 °C / -40...+80 °C ±150 ppm/°C ±250 ppm/°C ±200 ppm/°C at min. offset ±400 ppm/°C at max. offset rigid plug-connector with screw terminals 0.2-2.5 mm 2 (24-12 AWG) fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm 2 (24-12 AWG) 7 mm (0.28 inch) 0.4 Nm (3.5 ib.in) Test voltage (between all isolated circuits) 2) sors PT10, PT100, PT1000 (IEL 751 and JICC 1604) CC-U/TC Thermocouples any DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter Stripping length Tightening torque Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) electromagnetic field (HF radiation resistance) fast transients (Burst) powerful impulses (Surge) HF line emission Interference emission Isolation data Isolation test (between all isolated circuits) 1) CC-U/RTD 3) Voltage Potentio- Temperature sen- IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 EN 61000-6-4 EN 61000-6-2 Level 3 (±6 kV / ±8 kV) 10 V/m Level 3 (±2 kV / 5 kH) ±2 kV / ±1 kV 10 V Class B 1.5 kV 1.5 kV / 50 Hz Includes non-linearity and factory setting, influenced by supply voltage and output load. Detection of an input signal break (fail safe) and resistance > 10 kq results in a linearity of w0.2 %. When connecting a 2-wire sensor, the terminals J and H have to be jumpered. Approvals on page 4/4. 4/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Analog signal converters - CC-U range Technical data Type CC-U/STDR Input circuits - Analog inputs J-H Input resistance Adjustable threshold Adjustable hysteresis Repeat accuracy (constant parameters) Output circuits - Relay outputs Rated switching voltage Rated switching c urrent E-D-F, B-C-A AC-12 (resistive) 230 V AC-15 (inductive) 230 V DC-12 (resistive) 24 V DC-13 (inductive) 24 V Utilization category (Control Circuit Rating Code) max. rated operational voltage max. continuous thermal current at B 300 max. making/breaking apparent power at B 300 Minimum switching voltage Minimum switching current / power Response time Mechanical lifetime Electrical lifetime Supply circuits Rated supply voltage Supply voltage range Supply voltage tolerance Rated frequency Power consumption Indication of operational states Supply voltage 1st / 2nd output relay energized General data Ambient temperature range Temperature coefficient Mounting position Mounting Electrical connection Wire size at AC-12, 230 V, 4 A K-M CC-U/RTDR 1) CC-U/TCR Temperature sensors Thermocouples (IEC 584-1 and 2) 0-1 V / PT100 TC.K, TC.J 1-5 V TC.T, TC.S 0-10 / ±10 V approx. approx. 50 1.5 M 2-100 % of selected input range 5-50 % of threshold ±0.5 % of full-scale Relay, 2 c/o contacts 250 V AC 4A 3A 4A 2A B 300 300 V AC 5A 3600/360 VA 12 V 10 mA / 0.6 VA (W) 10 ms 30 x 10 6 switching cycles 0.1 Mio. switching cycles DC versions AC versions 24-48 V DC 24-48 V DC / 24 V AC DC: -15...+15 % 0 Hz or 50/60 Hz 2 W at 24 V DC 110-240 V AC 110-240 V AC / 100-300 V DC AC: -15...+10 % 4.5 VA at 230 V AC U: green LED R1: yellow LED / R2: yellow LED operation / storage -20...+60 °C / -40...+80 °C ±300 ppm/°C any DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter 2 rigid plug-connector with screw terminals 0.2-2.5 mm (24-12 AWG) 2 fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm (24-12 AWG) 7 mm (0.28 inch) 0.4 Nm (3.5 ib.in) Stripping length Tightening torque Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) electromagnetic field (HF radiation resistance) fast transients (Burst) powerful impulses (Surge) HF line emission Interference emission Isolation data Insulation voltage (between all isolated circuits) Test voltage (between all isolated circuits) 1) Voltage 0-20 mA 4-20 mA Measuring signal / input range AC rating (UL 508) Current IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 EN 61000-6-4 EN 61000-6-2 Level 3 (±6 kV / ±8 kV) 10 V/m Level 3 (±2 kV / 5 kH) ±2 kV / ±1 kV 10 V Class B 2.5 kV 2.5 kV When connecting a 2-wire sensor, the terminals J and H have to be jumpered. Approvals on page 4/4. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/30 4 Analog signal converters - CC-U range Technical data Type Input circuits - Analog inputs J-G-H 0-1 A 0-5 A Rated input range Gain adjustment range Offset adjustment range Input impedance / resistance Output circuits - Analog outputs Output signal Output load Accuracy1) Temperature coefficient Residual ripple Response time Supply circuits Rated supply voltage Supply voltage range Supply voltage tolerance Rated frequency Power consumption Indication of operational states Supply voltage General data Ambient temperature range Mounting position Mounting Electrical connection Wire size RMS measurement RMS measurement 0-100 V, 0-150V, 0-250 V 0-300 V, 0-400 V, 0-450 V 0-550 V, 0-600 V - > 800 k Voltage 0-5 V, 1-5 V, 0-10 V, 2-10 V, ± 10 V 4.7 K ±300 ppm/°C max. AC versions 110-240 V AC 110-240 V AC, 100-300 V DC AC: -15...+10 % 4.5 VA at 230 V AC U: green LED operation / storage -20...+60 °C / -40...+80 °C any DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter rigid plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG) fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG) 7 mm (0.28 inch) 0.4 Nm (3.5 lb.in) Stripping length Tightening torque Standards Product standard Low Voltage directive EMC directive RoHS directive Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) electromagnetic field (HF radiation resistance) fast transients (Burst) powerful impulses (Surge) HF line emission Interference emission Isolation data Insulation voltage (between all isolated circuits) Test voltage (between all isolated circuits) 1) CC-U/V any voltage signals, 0-600 Hz input range 1 10 x I Nom (10 A) for max. 2 s input range 2 10 x I Nom (50 A) for max. 2 s ±15 % ±20 % 1A: 60 m, 5 A: 12 m Current D-F, A-C 0-20 mA, 4-20 mA 600 ±0.5 % of full-scale ±250 ppm/°C max. < 0.15 % 150 ms DC versions K-M 24-48 V DC 24-48 V DC, 24 V AC DC: -15...+15 % 0 Hz or 50/60 Hz 2 W at 24 V DC Measuring frequency Overload capacity of inputs 4 CC-U/I any current signals, 2006/95/EC 2004/108/EC 2011/65/EC IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 EN 61000-6-4 EN 61000-6-2 Level 3 (±6 kV / ±8 kV) 10 V/m Level 3 (±2 kV / 5 kH) ±2 kV / ±1 kV 10 V Class B 1.5 kV 1.5 kV / 50 Hz Includes non-linearity and factory setting, influenced by supply voltage and output load. Approvals on page 4/4. 4/31 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Analog signal converters - CC-U range Technical diagr., Connection diagr., Dimensional drawings Technical diagrams Load limit curves CC-U/xxR Resistive DC load L K J H G 4 1.0 0.9 0.8 D E F A B C 2CDC 282 023 F0b06 Derating curve M 2CDC 282 026 F0b06 2CDC 282 025 F0b06 Resistive AC load Connection diagram CC-U/x Width 22.5 mm (0.89 in) F 0.7 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 cos Dimensional drawings 0.9 1.0 2CDC 282 014 F0b06 0.6 Dimensions in mm and inches .039 2CDC 282 024 F0b06 CC-U/x , CC-U/xR 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/32 Serial data converters Product picture 4 4/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Serial data converters Table of contents Serial data converters Benefits and advantages 4/35 Selection table 4/36 Ordering details 4/37 Technical information 4/38 Technical data 4/46 4 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/34 Serial data converters Benefits and advantages ILPH RS 232 - 485 / Ethernet –– Electrical isolation between power supply and input/output –– RS232 on SUBD 9 points or screw connectors –– RS485 on removable screw connectors –– Ethernet 10/100 Mbit/s, RJ45 connector –– Power supply 10-34 VDC and 10-24 VAC –– Possible to have a redundant 10-34 VDC power supply –– Economic with low consumption –– Up to 100m with CAT5 cable without Hub or Switch –– Good EMC characteristics –– Up to 2 Modbus®\TCP Masters 4 Available modes: –– Modbus®\TCP to Modbus® RTU –– Transparent Client or Server mode –– SMTP mode (Mail mode) Standards: TPC/IP, TELNET, DHCP, FTP –– Specifics functions in Modbus® protocol: –– Concentrator (Asynchronous mode) up to 1200 words –– AC31 programming Modbus® Easy Net mode : this mode could be used to exchange data without a Modbus®/TCP master. The data are logged in a table and could be distributed to one or all the others e-ILPH participants on Ethernet. ILPH RS 232 / RS 422 - 485 –– Electrical isolation between power supply and input/output –– RS 485 switch on 2 or 4 wires –– Baudrate up to 38.4 kbit/s –– Transmission distance up to 1200 m –– RS 485 1 or 2 pair handling –– Usable in "noisy" environments –– 24...48 V DC and 115...230 V AC power supply –– CE marked ILPH RS 422 - 485 / RS 422 - 485 Electrical isolated connection between an RS 422-485 (1 or 2 pairs) and an RS 422 485 (1 or 2 pairs) serial link. It amplifies the signal beyond the 1200 m limit distance of the RS 422485 and only needs a minimum of 1.5 character delay time to switch off the RS 485 drivers. –– Electrical isolation between power supply/output and input/ output –– Baudrate up to 500 kbit/s (up to 200 m) –– Transmission distance up to 1200m at 38.4 kbit/s –– Usable in "noisy" environments –– 2/4 wires automatic handling –– 24 V DC power supply –– CE marked ILPH RS 232 / RS 422 - 485 RS 232 to RS 422-485 serial link with or without electrical isolation –– Baudrate up to 38.4 kbit/s –– Transmission distance up to 1200 m –– RS 485 1 or 2 pair handling –– Usable in "noisy" environments –– 24 V DC power supply –– CE marked ILPH RS 485 / FO Converter for RS 485 (1 pair) to optical fiber serial link glass. – – Electrical isolation between power supply and input/output – – Baud rate up to 1.5 Mbit/s – – Transmission distance up to 4 km – – Usable in "very noisy" environments – – 20...42 V AC/DC power supply – – CE marked ILPH RS 232 / CL Electrical isolated Converter for RS 232 to current loop serial link. – – Electrical isolation between power supply/current loop and RS 232/current loop – – Active/Passive 0...20 mA / 4...20 mA selectable Positive or negative logic selectable – – Baudrate up to 38.4 kbit/s – – Transmission distance up to 1200 m – – Usable in "noisy" environments – – 24 V DC power supply – – CE marked ILPH RS 232 / RS 232 3 way electrical isolator between RS 232 serial interface and another RS 232 serial interface. –– Ensures triple insulation between the 2 serial interfaces and between each and power supply –– Baudrate up to 19.2 kbit/s (up to 64 kbit/s depending on cable) –– Transmission distance up to 15 m –– Can be used in "noisy" environments –– Power supply from 24...48 V DC and 115...230 V AC CE marking ILPH RS 232 / FO – – Converter for RS 232 to fiber optical serial link glass. – – Electrical isolation between power supply and input/output – – Baud rate up to 115.2 kbit/s – – Transmission distance up to 4 km – – Usable in "very noisy" environments – – 20...42 V AC/DC power supply – – CE marked ILPH CL / RS 422 - 485 Electrical isolated converter for current loop to RS 422-485 (1 or 2 pairs) serial link. – – Electrical isolation between power supply/current loop and RS 422-485/current loop – – Active/passive 0...20 mA / 4...20 mA selectable Positive or negative logic selectable – – Baudrate up to 38.4 kbit/s (up to 2400 m) Transmission distance up to 2400 m (1200 m RS 485 and 1200 m current loop) – – Usable in "noisy" environments – – 24 V DC power supply – – CE marked 4/35 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 RS 232 10-34 VDC, 10-24 VAC 24-42 V AC/DC 110-240 V AC 24-48 V DC 24 V DC Ethernet FO-S CL RS 422 / RS 485 RS 232 Serial data converters Selection table Insulation IN=Input PS=Power supply Out=Output Wi=Without insulation In-Ps-Out Part numbers 1SNA 684 234 R2000 Wi 1SNA 684 231 R2500 In-Out 1SNA 684 233 R2700 In-Ps-Out 1SNA 684 333 R2300 In-Ps-Out 1SNA 684 334 R2400 In-Out 1SNA 684 202 R0100 In-Ps-Out 1SNA 684 236 R2200 In-Out 1SNA 684 212 R2200 In-Out 1SNA 684 232 R2600 RS 485 In-Ps-Out 1SNA 684 246 R0400 RS 232 / RS 485 In-Ps-Out 1SNA 684 252 R0200 RS 422/RS485 RS 232 - EIA-232 / V.24 / V.28 –– Point-to-point connection –– Max. 15 m transmission distance –– Rate up to 19.2 kbit/s –– Full-duplex RS 422 - EIA-422 / V.11 –– Point-to-point connection –– (1 Transmitter - 10 Receivers) –– Differential voltage transmission –– Full-duplex –– Up to 1200 m/ 10 Mbit/s –– Good EMC characteristics Current loop(TTY) –– Point-to-point / multi-point connection –– Active or passive current loop –– Full-duplex –– Up to 1200 m/19.2 kBit/s –– Good EMC characteristics RS 485 - ISO/IEC/EIA-485 – – Multi-point connection up to 32 units – – Differential voltage transmission – – Half-duplex on 1 pair – – Full-duplex on 2 pairs – – Up to 1200 m / 10 Mbit/s – – Good EMC characteristics Optical fiber interface – – Point-to-point connection – – Full-duplex – – From 40 m up to 4km transmission distance – – Excellent EMC characteristics Ethernet Interface – – Point to point connexion or multipoint connection. – – Up to 100 m using CAT5 cable without Hub or Switch – – 10/100 Mbit/s – – Good EMC characteristics 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/36 4 Serial data converters Ordering details 2CDC 281 003 F0013 Ordering details ILPH RS 232-RS 485 / Ethernet Type Order code Serial data converter e-ILPH ILPH RS 232-RS 485 / Ethernet 1SNA684252R0200 0.12 (0.265) Serial link interface without electrical isolation ILPH RS 232 / RS 422-485 1SNA684231R2500 0.1 (0.220) Serial link interface with electrical isolation ILPH RS 232 / RS 422-485 1SNA684233R2700 0.1 (0.220) ILPH RS 232 / RS 422485 (24-48 V DC power supply) 1SNA684333R2300 ILPH RS 232 / RS 422485 (115-230 V AC power supply) 1SNA684334R2400 ILPH RS 232 / RS 232 (24-48 V DC power supply) 1SNA684234R2000 ILPH RS 232 / RS 232 (115-230 V AC power supply) 1SNA684234R0200 Serial link interface with electrical isolation ILPH RS 422 - 485 / RS 422 - 485 (24 V DC power supply) 1SNA684212R2200 0.1 (0.220) Serial link interface 3 way electrical isolation ILPH RS 232 / FO-S (24...42 V AC/DC power supply) 1SNA684236R2200 0.15 (0.331) Serial link interface 3 way electrical isolation ILPH RS 485 / FO-S (24...42 V AC/DC power supply) 1SNA684246R0400 0.15 (0.331) Serial link interface with electrical isoaltion ILPH BdC /RS 422 - 485 (24 V DC power supply) 1SNA684232R2600 0.1 (0.220) Serial link interface with electrical isolation ILPH RS 232 (24 V DC power supply) 1SNA684202R0100 0.1 (0.220) Serial link interface 3 way electrical isolation Serial link interface 3 way electrical isolation 2CDC 281 001 S0013 4 Description ILPH RS 232 / RS 422-485 4/37 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Price Weight (1 pce) kg (lb) 0.1 (0.220) 0.1 (0.220) Serial data converters Technical information ILPH RS 232 - 485 Ethernet 1SNA684252R0200 SubD9 connector pin 2 = RX pin 3 = TX pin 5 = GND pin 7 = RTS GND RX TX K L 3 4 4 5 6 7 K 3 8 TX 2 GND 1 PW RX R ON M L G 2 H 1 ON J K L M M LIN D D ern A E D ACTIVITY SPEED et e-ILPH K TX RX Eth D center of rail E B2- A 4 B1+ +24V 0V 24V ILPH RS 232 / RS 422-485 (without isolation) 1SNA684231R2500 RS 422 - RS 485 SERIAL LINK (2 wires) RS 422 - RS 485 SERIAL LINK (4 wires) Product RS 232 Product RS 232 Connector J1 Connector J1 24 V DC power supply 24 V DC power supply Product RS 422-RS 485 Product RS 422-RS 485 *CAUTION: When the RTS Signal is not activated, M terminal (RxD ILPH) has to be connected to L terminal (CTRL IN). RS 485 LINK ON ONE PAIR R without isolation E R ON/ OFF Jumper R in position RON/OFF E ON/ OFF Jumper E in position EON/OFF The Receiver and the Transmitter are activated alternately (never at the same time) depending on the status of the CTRL IN signal. POLARIZATION OF THE RS 422 - RS 485 LINE Connection by 1 wire P+ (J1.1) with 5V (J1.4) Connection by 1 wire P- (J1.2) with 0V (J1.3) RS 485 LINK ON TWO PAIRS 0 logic (+3V m U m +25V) 1 logic (-25V m U m -3V) High impedance R ON ACTION ON RS 485 Transmitter active / Receiver inactive Transmitter inactive / Receiver active Transmitter inactive / Receiver active NOTE : For RS 232 products running the RTS (REQUEST TO SEND) signal, connect RTS to CTRL IN. Otherwise, connect M (RxD ILPH) to L (CTRL IN). without isolation E E ON/ OFF Configuration of the jumper Rt R E RS422 LINK ON TWO PAIRS The line must always be polarized. The ILPH is used to polarize the reception channel : R CTRL IN STATUS ** CAUTION : To be connected to 2 wired RS 485 only (not possible for 4 wired RS 422). When the RTS Signal is not activated, M terminal (RxD ILPH) has to be connected to L terminal (CTRL IN). Jumper R in position RON Jumper E in position EON/OFF Receiver permanently active Transmitter controlled by the signal CTRL IN (see table for Transmitter operation as a function of CTRL IN) without isolation R R ON Jumper R in position RON E E ON Jumper E in position EON The Transmitter and Receiver are both permanently active. ADAPTING THE RS 422 - RS 485 LINE The line must always be adapted to the level of the reception channel of each subscriber forming the end of the bus. The ILPH is used to adapt the reception channel by setting the jumper Rt correctly : * Line adaptation, Rt = 120 Ω (general case ) Rt * Line adaptation, Rt = 220 Ω * No line adaptation, Rt = ∝ 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/38 Serial data converters Technical information ILPH RS 232 / RS 422-485 (with isolation) 1SNA684233R2700 RS 422 - RS 485 WIRE SERIAL LINKS RS 422 - RS 485 WIRE SERIAL LINKS RS 232 product RS 232 product 4 Connector J1 Connector J1 24 V DC power supply 24 V DC power supply RS 422-RS 485 product RS 422-RS 485 product * CAUTION : If the RTS signal is not generated, connect M (RxD ILPH) to L (CTRL IN). RS 485 LINK ON ONE PAIR R Isolated E R ON/ OFF E ON/ OFF Jumper R in position RON/OFF Jumper E in position EON/OFF The Receiver and the Transmitter are activated alternately (never at the same time) depending on the status of the CTRL IN signal. CTRL IN STATUS ACTION ON RS 485 1 logic (-25 V m U m -3V) High impedance Transmitter inactive / Receiver active Transmitter inactive / Receiver active 0 logic (+3 V m U m +25 V) Transmitter active / Receiver inactive NOTE : For RS 232 products running the RTS (REQUEST TO SEND) signal, connect RTS to CTRL IN. Otherwise, connect M (RxD I LPH) to L (CTRL IN). Rt ** CAUTION : Only to be connected for RS 485 two pairs (of no use for RS 422 two pairs). If the RTS signal is not generated, connect M (RxD ILPH) to L (CTRL IN). POLARIZATION OF THE RS 422 - RS 485 LINE Connection by 1 wire P+ (J1.1) with 5V (J1.4) Connection by 1 wire P- (J1.2) with 0V (J1.3) RS 485 LINK ON TWO PAIRS R R ON Jumper R in position RON E E ON/ OFF Jumper E in position EON/ OFF Receiver permanently active Transmitter controlled by the signal CTRL IN (see table for Transmitter operation as a function of CTRL IN) 4/39 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 R E RS422 LINK ON TWO PAIRS The line must always be polarized. The ILPH is used to polarize the reception channel : Isolated Configuration of the jumper Isolated R R ON Jumper R in position RON E E ON Jumper E in position EON The Transmitter and Receiver are both permanently active. ADAPTING THE RS 422 - RS 485 LINE The line must always be adapted to the level of t he reception channel of each subscriber forming the end of the bus. The ILPH is used to adapt the reception channel by setting the jumper Rt correctly : * Line adaptation, Rt = 120 Ω (general case ) Rt * Line adaptation, Rt = 220 Ω * No line adaptation, Rt = ∝ Serial data converters Technical information ILPH RS 232 / RS 422 - 485 (eletrical isolated) 1SNA684333R2300, 1SNA684334R2400 RS 422 - RS 485 2 WIRE SERIAL LINK RS 422 - RS 485 4 WIRE SERIAL LINKS Product RS 232 Product RS 232 4 Connector J1 Connector J1 Power supply Power supply Product RS 422 - RS 485 Product RS 422 - RS 485 **CAUTION : *CAUTION : SW2 SW1 Configuration of the jumper 8 7 6 5 43 2 1 OFF ON SW1 OFF ON SW2 21 When the RTS signal is not generated, set SW2-1 in position ON. Only to be connected for RS 485 two pairs (of no use for RS 422 two pairs). If the RTS signal is not generated, set SW2-1 in position ON. RS 485 LINK ON ONE PAIR RS 422 LINK ON TWO PAIRS Set SW1-1, SW1-3, SW1-6, SW1-7 and SW1-8 to position ON. The receiver and the transmitter are activated alternately (never at the same time), depending on the status of the CTRL IN signal. Set SW1-1, SW1-3, SW1-7 and SW1-8 in position OFF. Set SW1-6 in position ON. Transmitter and receiver are both permanently active. CTRL IN STATUS 0 Logic (3 V m U m + 25 V) 1 Logic (-25 V m U m -3 V) High impedance Action on RS 485 Transmitter active / Receiver inactive Transmitter inactive / Receiver active Transmitter inactive / Receiver active CAUTION : For RS 232 products running the RTS signal (REQUEST TO SEND), connect RTS to CTRL IN. Otherwise, set SW2-1 to position ON. RS 485 LINK ON TWO PAIRS Set SW1-1, SW1-3, SW1-7 in position OFF. Set SW1-6, SW1-8 in position ON. The receiver is permanently active. The transmitter is controlled by the signal CTRL IN (see table for transmitter operation as a fonction of CTRL IN). POLARIZATION OF THE RS 422 - RS 485 LINE The line must always be polarized. The ILPH is used to polarize the reception channel. Set SW1-4 and SW1-5 in position ON. ADAPTING THE RS 422 - RS 485 LINE The line must always be adapted to the level of the reception channel of each subscriber forming the end of the bus. The ILPH is used to adapt the reception channel by setting the jumper SW1-2 correctly : SW1-2 in position ON ⇒ line adaptation Rt = 120 Ω (standard) SW1-2 in position OFF ⇒ no line adaptation Rt = ∝ 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/40 Serial data converters Technical information ILPH RS 232 / RS 232 (eletrical isolated) 1SNA684234R2000, 1SNA684244R0200 Terminal equipment for ETTD (DTE) data processing Connection not advised according to EIA/TIA 232E standard (to be connected) 4 center of rail or Connection not advised according to EIA/TIA 232E standard Data transmission end equipment ETCD (DCE) ILPH RS 232 / FO 1SNA684236R2200 (L) (M) TxD RxD OV (K) (J Shielding H G) FO Sending (B) ← → FO Receiving (F) (A) Shielding (D) OV (E) (C) ~ ~+ 4/41 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Serial data converters Technical information ILPH RS 485 / FO 1SNA684246R0400 D-D+ OV Polarization configuration of the micro-switch SW 2 1 2 3 4 5 6 OFF Shielding 4 FO Sending ← → FO Receiving Baud rate: SW1 DIP switch configuration Baudrate bit/s SW 1 1 2 M M M M M M M M M M 1500000 500000 375000 187500 136000 115200 93750 75000 57600 38400 19200 M 9600 4800 300 M M Shielding OV 3 M 4 M M M M M M M M M M 5 M M M M M M M 6 7 8 ~ ~ + Baud rate configuration of the micro-switch SW 1 M M M M M M M M M M M M M 4 5 6 M M M M M M M 1 2 3 4 5 6 7 8 OFF M M M M M M M End-of-line resistor, polarization: SW2 DIP switch configuration Baudrate bit/s SW 2 1 2 Polarization M EOL 60 ohm EOL 120 ohm EOL 180 ohm EOL 240 ohm EOL indefinite 3 M M 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/42 Serial data converters Technical information ILPH RS 422 - 485 / RS 422 / - 485 1SNA684212R2200 RS 422 - RS 485 4 wire serial link RS 422 - RS 485 2 wire serial link Channel 1 configuration of the micro-switch INT 4 1 2 3 4 Channel 1 configuration of the microswitch 1 OFF INT 4 1 2 3 4 OFF 4 Connector J1 Connector J1 BAUD RATE FULL DUPLEX 500 Kb/s 187.5 Kb/s 93.75 Kb/s 38.4 Kb/s 19.2 Kb/s 9.6 Kb/s 4.8 Kb/s 2.4 Kb/s 1.2 Kb/s INT 1 INT 2 INT 3 INT 4 1234 1234 1234 123456 0000 0000 XXX1 XXX101 1111 1111 XXX0 XXX000 1111 1110 XXX0 XXX000 1111 1100 XXX0 XXX000 1111 1000 XXX0 XXX000 1111 0000 XXX0 XXX000 1110 0000 XXX0 XXX000 1100 0000 XXX0 XXX000 1000 0000 XXX0 XXX000 0000 0000 XXX0 XXX000 Nu = not used X = zero 24 V DC power supply 24 V DC power supply Caution : The transmission channels of both RS 422 - RS 485 serial link interfaces always have to be independently polarized. 1 = contact closed 0 = contact open (aus) (off) center of rail Baud rate configuration of the micro-switch INT 1 RS 422 - RS 485 DRIVERS CONTROL The RS 422 - RS 485 Drivers Control (transmitters and receivers) makes the ILPH easy to use. The control of the 2 channels is completely automatic ; you only have to configure the baud rate needed. The minimum turn off delay is about 1.5 character/ time from 27 µs to 10 ms depending on the baud rate selected. POLARIZATION OF THE RS 422 RS 485 CONNECTIONS The connections must always be polarized. The ILPH is used to polarize the reception channels: INT 3 1 2 3 4 INT 3.1 INT 3.2 OFF "ON", polarizes the reception channel Rx2 INT 4 1 OFF 2 3 4 ADAPTING THE RS 422 RS 485 CONNECTIONS 6 INT 4.1 INT 4.2 "ON", polarizes the reception channel Rx1 OFF The connections must always be adjusted to the level of the reception channel of each subscriber forming the end of the bus. The ILPH is used to adjust the reception channel by setting the microswitch INT 3.3 and INT 4.3. INT 4 INT 3 1 2 3 4 1 OFF 2 3 4 OFF 5 6 INT 3.3 and INT 4.3 "ON" 120 Ω set adjustment BAUD RATE By using the 8 micro-switches inside the box. INT 1 1 OFF 5 1 2 3 2 3 INT 2 4 1 2 3 4 OFF Permits to define up to 8 transmission speeds and to select the Full Duplex operation mode (RS 422 / RS 422) in addition with the INT 3.4 INT 4.4 and INT 4.5 micro switches. 4/43 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 INT 2 4 1 2 3 4 OFF Serial data converters Technical information ILPH CL / RS 422 - 485 1SNA684232R2600 LINE AMPLIFIER CONFIGURATION Configuration of amplifiers of the RS 422 - RS 485 (Receiver, Transmitter) line provides greater flexibility of use.The various configurations can be selected using the 2 jumpers (R INT2, E INT1) located inside the box. RS 485 LINK ON ONE PAIR R INT2 E INT3 R ON/OFF Jumper R in position R ON/OFF E ON/OFF Jumper E in position E ON/OFF The Receiver and the Transmitter are activated alternately (never at the same time) depending on the status of the Current Loop Reception signal. RS 485 LINK ON TWO PAIRS INT2 R ON R INT3 E E ON / OFF R ON Jumper R in position R ON E ON/OFF Jumper E in position E ON/OFF 4 RS 422 - RS 485 2 wire serial link RS 422 - RS 485 4 wire serial link Current Loop Current Loop Receiver permanently active. Transmitter controlled by the Current Loop Reception signal. RS 422 LINK ON TWO PAIRS R INT2 R ON E INT3 E ON R ON E ON Jumper R in position R ON Jumper E in position E ON Connector J1 Connector J1 The Receiver and the Transmitter are both permanently active. 24 V DC power supply POLARIZATION OF THE RS 422 - RS 485 LINE Note : The TxD channel of the RS 422 - RS 485 link must be polarized independently too. The line must always be polarized. The ILPH is used to polarize the reception channel : Connection by 1 wire P+ (J1.1) with 5 Viso (J1.4) Connection by 1 wire P- (J1.2) with 0 Viso (J1.3) ADAPTING THE RS 422 - RS 485 LINE The line must always be adapted to the level of the reception channel of each subscriber forming the end of the bus. The ILPH is used to adapt the reception channel by setting the jumper Rt correctly : Rt INT1 Rt INT1 ON S1 S2 S3 S4 OFF Legend on off 24 V DC power supply CONNECTIONS Example of connection with a CL (current Loop) product, Transmission (TxD) in active mode and Reception (RxD) in passive mode. Then, the ILPH must be configured and connected Reception (RxD) in passive mode and Transmission (TxD) in active mode. Note : For any other configuration, see schematic diagram or front sticker of the product. * Line adaptation, Rt = 120 Ω (Standard) * No line adaptation, Rt = ∞ Transmission (TxD) active Transmission(TxD) passive Reception (RxD) active Reception (RxD) passive 4...20 mA Signal 0...20 mA Signal Signal logic 1 = 20 mA Signal logic 0 = 20 mA Configuration of the jumper Rt E R INT1 INT2 INT3 Polarization Configuration of the microswitches 1 2 3 4 INT4 POLARIZATION The polarization can be configured using the INT4 jumper. INT4 INT4 Protection ON Protection OFF, used if power supply at minimum value (21.6 V). 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/44 Serial data converters Technical information ILPH RS 232 / CL 1SNA684202R0100 CONFIGURATION The various configurations can be selected using the 4 micro-switches located inside the box. OPERATING MODE ACTIVE OR PASSIVE The Current Loop's Transmission and Reception can be independently in active or passive mode. Select operating mode using S1 and S2. S1 S2 S3 S4 ON 4 OFF CONNECTIONS Example of connection with a CL (Current Loop) product, Transmission (TxD) in active mode and Reception (RxD) in passive mode. Then, the ILPH must be configured and connected Reception (RxD) in passive mode and Transmission (TxD) in active mode. 24 V DC power supply CAUTION: For any other configuration, see schematic diagram or front sticker of the product. Current loop S1 S2 Transmission(TxD) ON = Active / OFF = Passive Reception (RxD) ON = Active / OFF = Passive SIGNAL LEVEL Select signal level 4-20 mA or 0-20 mA. This selection is made using microswitch S3 ON S1 S2 S3 S4 S3 ON = 4-20 mA / OFF = 0-20 mA OFF Caution : It is not possible to select a 4-20 mA signal when the Reception is in active mode. LOGIC LEVEL Configuration: Positive logic or negative logic (0 Logic = 20 mA) (1 Logic = 20 mA) using micro-switch S4 S1 S2 S3 S4 ON OFF ILPH RS 232 / CL Configuration of the micro-switches S1 S2 S3 S4 center of rail 4/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 S4 ON = (1 = 20 mA) / OFF = (0 = 20 mA) Serial data converters Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated ILPH RS 232 - 485 / Ethernet Power supply 1 Voltage Voltage tolerance Consumption Connections Power supply 2 Voltage Voltage tolerance Consumption Connections Serial link 1: RS 232 Overvoltage protection Baud rate / Transmission distance Connections Serial link 2: RS 485 Voltage Line polarization End line resistance Baud rate / Transmission distance Connections Ethernet link Overvoltage protection Baud rate / Transmission distance Connections Traffic indication Voltage Status of signal EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Surge Electromagnetic compatibility Other characteristics Electrical isolation between serial link / power supply / Ethernet link Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight 10...34 V DC, 10...24 V AC -10%, +10% 2 W max coding screw removable connector 0 to 2.5 mm² (22-14 AWG) 10...34 V DC -10%, +10% 2 W max screw connector (AWG 20) EIA RS 232 integrated max. 115.2 kbits/s / max. 15 m 2.5 mm² screw connector (AWG 20) or male SubD 9 points EIA RS 485 integrated integrated integrated max. 115.2 kbits/s / max. 1200 m coding screw removable connector 0 to 2.5 mm² (22-14 AWG) integrated 10-100 Mbits/s / max. 100 m without Hub or Switch with CAT5 cable RJ45 connector 1 yellow LED 3 green LED (RxD, TxD, LINK), 2 amber or green LED (Speed, Activity) EN EN EN EN EN 61000-4-2 61000-4-3 61000-4-4 61000-4-5 55022 750 VDC / 1500 VAC using internal switches or/and software (TELNET or HYPERTERMINAL) 0°C ... +60°C -20°C ... +70°C any required snap-on mounting 2.5 mm² / stranded with ferrule, 4 mm² solid 94 x 22.5 x 100 mm 120 g 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/46 4 Serial data converters Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated ILPH RS 232 / RS 422 - 485 (without isolation) 4 Power supply Voltage Voltage tolerance Supply current Connections Serial link 1: RS 232 Overvoltage protection Baud rate / Transmission distance Connections Serial link 2: RS 422-485 Overvoltage protection Baud rate / Transmission distance Connections Traffic indication Voltage Connections EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Electrical isolation between serial link / power supply / Ethernet link Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight polarized 24 V DC 8.5...28 V DC 100 mA max removable screw connectors (AWG 20) EIA RS 232 C / CCITT V24 V28 integrated (transil 8 kV 1.2/50 µs) max. 38.4 kbits/s / max. 1200 m 2.5 mm² screw connectors (AWG 20) EIA RS 485 and EIA RS 422 / CCITT V11 integrated (transil 8 kV 1.2/50 µs) max. 38.4 kbits / max. 1200 m 2.5 mm² screw connectors (AWG 20) 1 yellow LED 2 green LED (RxD, TxD) EN EN EN EN 61000-4-2 level 3 6/8 kV 61000-4-3 level 310 V/m 61000-4-4 level 3 1 kV 55022 class B no using internal jumper 0°C ... +50°C -25°C ... +80°C any required snap-on mounting 2.5 mm² / stranded with ferrule, 4 mm² solid 88 x 22.5 x 100 mm 100 g 4/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Serial data converters Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated ILPH RS 232 / RS 422 - 485 (isolated) Power supply Voltage Voltage tolerance Supply current Connections Serial link 1: RS 232 Overvoltage protection Baud rate / Transmission distance Connections Serial link 2: RS 422-485 Overvoltage protection Baud rate / Transmission distance Connections Traffic indication Voltage Connections EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Electrical isolation between serial link / power supply / Ethernet link Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight polarized 24 V DC 8.5...28 V DC 100 mA max Removable screw connectors (Omniconnect) EIA RS 232 C / CCITT V24 V28 integrated (transil 8 kV 1.2/50µs) max. 38.4 kbits/s / max. 15 m 2.5 mm² screw connectors (AWG 20) EIA RS 485 and EIA RS 422 / CCITT V11 integrated (transil 8 kV 1.2/50 µs) max. 38.4 kbits / max. 1200 m 2.5 mm² screw connectors (AWG 20) 1 yellow LED 3 green LED (RxD, TxD and CTRL-IN) EN EN EN EN 61000-4-2 level 3 6/8 kV 61000-4-3 level 310 V/m 61000-4-4 level 3 1 kV 55022 class B 500 V DC using internal jumper 0°C ... +50°C -25°C ... +80°C any required snap-on mounting 2.5 mm² / stranded with ferrule, 4 mm² solid 88 x 22.5 x 100 mm 100 g 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/48 4 Serial data converters Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated ILPH RS 232 / RS 422 - 485 (3 way electrical isolated) 4 Power supply Voltage Voltage tolerance Supply current Supply power Connections Serial link 1: RS 232 Overvoltage protection Baud rate / Transmission distance Connections Serial link 2: RS 422-485 Overvoltage protection Baud rate / Transmission distance Connections Traffic indication Voltage Connections EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Electrical isolation between RS 232 / Power supply / RSS 422-RS 485 Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight Polarization for DC model 24...48 V DC 115...230 V AC (50/60 Hz) -15% ... +20% -15% ... +15% 24 V DC<110 mA, 48 V DC<55 mA, 115 V AC<40 mA, 230 V DC<26 mA ~3W ~ 3 VA Removable screw connector (Omniconnect) EA / TIA RS 232 new revision / CCITT V24 V28 integrated (transil 8 kV 1.2/50 μs) max. 19,2 kbits/s / max. 15 m / 2500 pF 2.5 mm² screw (AWG 20) EIA / TIA RS 232 new revision / CCITT V24 V28 integrated (transil 8 kV 1.2/50μs) max. 19.2 kbits/s / max. 15 m 2.5 mm² screw (AWG 20) 1 yellow LED 4 green LED (RxD, RxC/D, TxD, TxC/D) EN EN EN EN 61000-4-2 level 3 6/8 kV 61000-4-3 level 3 10 V/m 61000-4-4 level 3 1 kV 55022 class B 1,5 kV No 0°C ... +50°C -25°C ... +80°C any required snap-on mounting 2.5 mm² / stranded with ferrule, 4 mm² solid 88 x 22,5 x 100 mm 100 g 4/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Serial data converters Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated ILPH RS 232 / RS 232 Power supply Voltage Voltage tolerance Supply current Supply power Connections Interface 1: RS 232 Overvoltage protection Transmission capacity / Transmission distance Connections Interface 2: RS 232 Overvoltage protection Transmission capacity / Transmission distance Connections Traffic indication Voltage Connections EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Electrical isolation between serial link / power supply / Ethernet link Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight DC model polarized 24...48 V DC 115...230 V AC (50/60Hz) -15%...+20% -15%...+15% 24 V DC<155 mA;48 V DC<77 mA;110 V AC<40 mA;230 V DC<26 mA ~ 3.15 W ~ 3.15 VA Removable screw connector (Omniconnect) EIA / TIA RS 232 new revision / CCITT V24 V28 integrated (transil 8 kV 1.2/50 µs) max. 19.2 kbits/s / max. 15 m / 2500 pF 2.5 mm² screw (AWG 20) EIA / TIA RS 232 new revision / CCITT V24 V28 integrated (transil 8 kV 1.2/50 µs) max. 19.2 kbits/s / max. 15 m 2.5 mm² screw (AWG 20) 1 yellow LED 4 green LED (RxD, RxC/D, TxD, TxC/D) EN EN EN EN 61000-4-2 level 3 6/8 kV 61000-4-3 level 3 10 V/m 61000-4-4 level 3 1 kV 55022 class B 1.5 kV No 0°C ... +50°C -25°C ... +80°C any required snap-on mounting 2.5 mm² / stranded with ferrule, 4 mm² solid 88 x 22.5 x 100 mm 100 g 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/50 4 Serial data converters Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated ILPH RS 422 - 485 / RS 422 - 485 4 Power supply Voltage Voltage tolerance Supply current Connections Interface 1: RS 422-485 Overvoltage protection RS 485 data switching Baud rate / Transmission distance Connections Interface 2: RS 422-485 Overvoltage protection RS 485 data switching Baud rate / Transmission distance Connections Traffic indication Voltage Connections EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Electrical isolation between RS 232 / Power supply / RSS 422-RS 485 Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight DC model polarized 24 V DC +/-15% 120 mA max. Removable screw connector (Omniconnect) EIA / RS 485 and EIA RS 422 / CCITT V11 integrated (transil 8 kV 1.2/50 µs) Time switching / Time delay transmission/reception 27 µs ...10 ms from 1.2 to 500 kbits/s / max. 1200 m up to 38.4 kbit/s 2.5 mm² screw (AWG 20) EIA / RS 485 and EIA RS 422 / CCITT V11 integrated (transil 8 kV 1.2/50 µs) Time switching / Time delay transmission/reception 27 µs ...10 ms from 1.2 to 500 kbits/s / max. 1200 m up to 38.4 kbit/s 2.5 mm² screw (AWG 20) 1 yellow LED 2 green LED (RxD, TxD, ) EN EN EN EN 61000-4-2 level 3 6/8 kV 61000-4-3 level 3 10 V/m 61000-4-4 level 3 1 kV 55022 class B 500 V DC using internal DIP switches 0°C ... +50°C -25°C ... +80°C any required snap-on mounting 2.5 mm² / stranded with ferrule, 4 mm² solid 88 x 22.5 x 100 mm 100 g 4/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Serial data converters Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated ILPH RS 232 / FO Power supplies Supply voltage Voltage tolerance Connections Interface 1: RS 232 Protection Max. speed / max. distance Connections Fiber optic interface 2 Type of fiber / Connections Wave length Max. transmission power Max. reception power Max. speed Max. distance Status indication Power supply / Data exchange EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Electrical isolation input / power supply / output Operating temperature Storage temperature Mounting Connections Dimensions (WxDxH) Weight 24...42 V AC/DC (50/60 Hz) 110...240 V AC/DC (50/60 Hz) -15% ... +10% -15% ... +10% Omniconnect pluggable connector CCITT V.24/DIN 66020- CCITT V.28 DIN 66259-EIA 232 E Integrated (transil 8 kV 1.2/50µs) Max. 115.2 kbits/s / max. 15 m / 2500 pF Omniconnect pluggable connector DIN VDE 0888-1 Multimode fiber Glass : ST connector; Plastic : FSMA screw connector Glass : 820 nm; Plastic : 655 nm Glass : 50/125 µm : -14.4 db/m; Glass : 62.5/125 µm : -14 db/m; Plastic : 980/1000 µm : -8 db/m Glass : -28 db/m; Plastic : -20 db/m Max. 115.2 kbits/s Glass : 50/125 µm : 3 km; Glass : 62.5/125 µm : 4 km; Plastic : 980/1000 µm : 40 m 1 green LED / 2 green LEDs (RxD, TxD) EN EN EN EN 61000-4-2 Level 3 6/8 kV 61000-4-3 Level 3 10 V/m 61000-4-4 Level 3 1 kV 55022 Class B 2.5 kV -20°C ... +60°C -40°C ... +85°C Onto DIN Rail (EN 50002) 14 AWG (2.5 mm²) fine stranded / 12 AWG (4 mm²) rigid 105 x 22.5 x 112 mm / 4.13 x 0.89 x 4.41" 150 g / 0.33 lb 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/52 4 Serial data converters Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated ILPH RS 485 / FO Power supplies Supply voltage Voltage tolerance Connections Interface 1: RS 232 Protection Max. speed / max. distance Connections Fiber optic interface 2 4 Type of fiber / Connections Wave length Max. transmission power Max. reception power Max. speed Max. distance Status indication Power supply / Data exchange EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Electrical isolation input / power supply / output Operating temperature Storage temperature Mounting Connections Dimensions (WxDxH) Weight 24...42 V AC/DC (50/60 Hz) 110...240 V AC/DC (50/60 Hz) -15% ... +10% -15% ... +10% Omniconnect pluggable connector ISO / IEC 8482 / DIN 66 259-4; EIA 485 Integrated (transil 8 kV 1.2/50µs) Max. 1.5 Mbits/s / max. 1200 m (38.4 kbit/s) Omniconnect pluggable connector DIN VDE 0888-1 Multimode fiber Glass : ST connector; Plastic : FSMA screw connector Glass : 820 nm; Plastic : 655 nm Glass : 50/125 µm : -14.4 db/m; Glass : 62.5/125 µm : -14 db/m; Plastic : 980/1000 µm : -8 db/m Glass : -28 db/m; Plastic : -20 db/m Max. 1.5 Mbits/s Glass : 50/125 µm : 3 km; Glass : 62.5/125 µm : 4 km; Plastic : 980/1000 µm : 40 m 1 green LED / 2 green LEDs (RxD, TxD) EN EN EN EN 61000-4-2 Level 3 6/8 kV 61000-4-3 Level 3 10 V/m 61000-4-4 Level 3 1 kV 55022 Class B 2.5 kV -20°C ... +60°C -40°C ... +85°C Onto DIN Rail 14 AWG (2.5mm²) / fine stranded, 12 AWG (4 mm²) rigid 105 x 22.5 x 112 mm / 4.13 x 0.89 x 4.41" 150 g / 0.33 lb 4/53 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Serial data converters Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated ILPH RS 422 - 485 (for current loop) Power supply Voltage Voltage tolerance Supply current Connections Interface 1: Current loop Logic level Baud rate / Transmission distance Connections Serial link 2: RS 422/485 Overvoltage protection Baud rate / Transmission distance Connections Traffic indication Voltage Status of signal EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Electrical isolation between input / output and power supply / output RS 422-485 power supply Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight DC model polarized 24 V DC +/-10% 120 mA max. Removable screw connector (Omniconnect) active/passive 0...20 mA / 4...20 mA, mode is settable 0 = 20 mA or 1 = 20 mA, settable max. 38.4 kbit/s / max. 1200 m 2.5 mm² screw (AWG 20) EIA RS 485 and EIA RS 422 / CCITT V 11 integrated (transil 8 kV 1.2/50 µs) max. 38.4 kbit/s / max. 1200 m 2.5 mm² screw (AWG 20) 1 yellow LED 2 green LED (RxD, TxD) EN EN EN EN 61000-4-2 level 2 4/4 kV 61000-4-3 level 3 10 V/m 61000-4-4 level 1 0.5 kV 55022 class B depending on Current Loop (active/passive); 500 V DC (active) / 2000 V DC (passive) 500 V DC using internal DIP switches 0°C ... +50°C -25°C ... +80°C any required snap-on mounting 2.5 mm² / stranded with ferrule, 4 mm² solid 88 x 22.5 x 100 mm 100 g 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/54 4 Serial data converters Technical data Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated ILPH RS 232 / CL 4 Power supply Voltage Voltage tolerance Supply current Connections Serial link 2: RS 232 Logic level Baud rate / Transmission distance Connections BdC serial link 2: RS 422/485 Overvoltage protection Baud rate / Transmission distance Connections Traffic indication Voltage Status signal EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Electrical isolation between Current loop / RS 232 Electrical isolation between Current loop / power supply Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight DC model polarized 24 V DC +/-10% 120 mA max. Removable screw connector (Omniconnect) EIA RS 232 C / CCITT V 24 V 28 integrated (transil 8 kV 1.2/50 µs) max. 38.4 kbit/s / max. 15 m 2.5 mm² screw (AWG 20) active/passive 0...20 mA / 4...20 mA mode settable 0=20 mA or 1=20 mA settable max. 38.4 kbit/s / max. 1200 m 2.5 mm² screw (AWG 20) 1 yellow LED 2 green LED (RxD, TxD) EN EN EN EN 61000-4-2 level 3 6/8 kV 61000-4-3 level 3 10 V/m 61000-4-4 level 3 1 kV 55022 class B depending on current loop (active/passive) 500 V DC (active) / 2000 V DC (passive) 500 V DC (active) / 2000 V DC (passive) using internal DIP switches 0°C ... +50°C -25°C ... +80°C any required snap-on mounting 2.5 mm² / stranded with ferrule, 4 mm² solid 88 x 22.5 x 100 mm 100 g 4/55 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Serial data converters Notes 4 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/56 Interface relays and optocouplers Product group picture 5 5/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Interface relays and optocouplers Table of contents Interface Relays and Optocouplers Pluggable interface relays.................................................................. 5/3 Table of contents 5/4 Benefits and advantages 5/5 Approvals and marks 5/7 Ordering details - CR-S range 5/8 Ordering details - CR-P range 5/9 Ordering details - CR-M range 5/10 Ordering details CR-P/M functional modules 5/13 Ordering details - CR-U range 5/14 Ordering details - CR-U accessories 5/15 Technical data - CR-P, CR-M, CR-U 5/16 Technical data, load limit curves - CR-P, CR-M, CR-U 5/18 Technical data - Sockets for CR-P and CR-M 5/19 Technical data - Sockets for CR-U 5/20 Technical data - CR-S range 5/21 Technical data - CR-S range sockets 5/22 Load limit curves 5/23 Connection diagrams 5/24 Dimensional drawings 5/25 Interface relays and optocouplers R600 range.................................. 5/27 Table of contents 5/28 Benefits and advantages 5/29 Type designators 5/30 Interface relays R600 range. . ............................................................ 5/31 Benefits and advantages 5/31 Selection 5/33 Ordering details 5/35 Connection diagrams 5/37 Technical data 5/38 General technical data 5/43 Dimensional drawings, Load limit curves 5/44 Optocouplers R600 range................................................................ 5/45 Selection 5/45 Ordering details 5/47 Connection diagrams 5/48 Technical data 5/49 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/2 5 Pluggable interface relays Product group picture 5 5/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Pluggable interface relays Table of contents Pluggable interface relays Benefits and advantages 5/5 Approvals and marks 5/7 Ordering details - CR-S range 5/8 Ordering details - CR-P range 5/9 Ordering details - CR-M range 5/10 Ordering details CR-P/M functional modules 5/13 Ordering details - CR-U range 5/14 Ordering details - CR-U accessories 5/15 Technical data - CR-P, CR-M, CR-U 5/16 Technical data, load limit curves - CR-P, CR-M, CR-U 5/18 Technical data - Sockets for CR-P and CR-M 5/19 Technical data - Sockets for CR-U 5/20 Technical data - CR-S range 5/21 Technical data - CR-S range sockets 5/22 Load limit curves 5/23 Connection diagrams 5/24 Dimensional drawings 5/25 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/4 5 Pluggable interface relays Benefits and advantages Slim relays CR-S –– Standard slim relays (5 mm), sockets (6.2 mm) and accessories –– Combination of 9 different rated control supply voltages possible: –– DC versions: 5 V, 12 V, 24 V –– AC/DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 230 V –– Output: 1 c/o (SPDT) contacts (6 A), standard and goldplated contacts –– Cadmium-free contact material –– All sockets with LED –– Screw and spring connection terminals –– Jumper bar (red, black, blue), marker and separator available as accessories 5 Pluggable pcb relays CR-P – – 9 different coil voltages –– DC versions: 12 V, 24 V, 48 V, 110 V –– AC versions: 24 V, 48 V, 110 V, 120 V, 230 V – – Output contacts: –– 1 c/o contact (16 A) or –– 2 c/o contacts (8 A) optionally equipped with gold contacts – – Logical or standard sockets – – Cadmium-free contact material – – Width of socket: 15,5 mm – – Pluggable function modules –– Reverse polarity protection/Free wheeling diode –– LED indication –– RC elements –– Overvoltage protection 1 1 2 2 3 4 3 4 4 6 7 4 1 Socket 2 Pluggable function module 1 Output contacts 3 Interface relay 2 Socket 4 Holder 3 Relay holder 4 Marker label 4 Marker 4 Interface relay 6 LED green: Control supply voltage applied 7 Control supply voltage 5/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Pluggable interface relays Benefits and advantages Pluggable miniature relays CR-M –– 2 different coil voltages – – DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V – – AC versions: 24 V, 48 V, 110 V, 120 V, 230 V –– Output contacts – – 2 c/o contacts (12 A) or – – 3 c/o contacts (10 A) or – – 4 c/o contacts (6 A) optionally equipped with gold contacts, LED and free wheeling diode –– Integrated test button for manual actuation and locking of the output contacts (blue = DC, orange = AC) that can be removed if necessary –– With or without integrated LED –– Logical or standard sockets –– Cadmium-free contact material –– Width on socket: 27 mm –– Pluggable function modules – – Reverse polarity protection/Free wheeling diode – – LED indication – – RC elements – – Overvoltage protection Pluggable universal relays CR-U – – 12 different coil voltages –– DC versions: 12 V, 24 V, 48 V, 110 V, 125 V, 220 V –– AC versions: 24 V, 48 V, 60 V, 110 V, 120 V, 230 V – – Output contacts –– 2 c/o contacts (10 A) or –– 3 c/o contacts (10 A) – – Integrated test button for manual actuation and locking of the output contacts (blue = DC, orange = AC) that can be removed if necessary – – With or without integrated LED – – Cadmium-free contact material – – Width on socket: 38 mm – – Pluggable function modules –– Reverse polarity protection/Free wheeling diode –– LED indication –– RC elements –– Overvoltage protection –– Multifunction time module 1 1 2 2 3 3 4 4 1 Socket 1 Socket 2 Pluggable function module 2 Pluggable function module 3 Interface relay 3 Interface relay 4 Holder 4 Holder 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/6 5 Pluggable interface relays Approvals and marks Kind of connecting terminals Kinds of sockets Standard sockets - Position of connecting terminals: Coil connection (A1-A2) on lower socket side, contact connections (n/o and n/c contacts) on the lower and upper socket side. Logical sockets - Position of connecting terminals: Coil connection (A1-A2) on lower socket side, all contact connections (common contacts, n/o and n/c contacts) on upper socket side. Details see connection diagrams Screw type Spring type Fork type 5 Approvals and marks J F CAN/CSA C22.2 No.14 J J J J VDE R EAC P Lloyds Register E CCC CQC L J 8) J J J J J J J 4) 5) J J J J J J1) J J2) J J3) J J J J J J J J J J J J J J J J CR-U J J CR-P/M J J CR-U..SM CAN/CSA C22.2 No.14 J CR-U..S CR-U..E cG CR-M..SF J CR-M..L.. CR-M..SS J CR-PLC J CR-PLS CR-PSS ANSI/UL 508 CR-S sockets G Approvals Modules CR-U CR-M Sockets CR-P Relays CR-S J existing j pending J J 6) J J J 6) J J J J J J J J J J J J J J 8) J J J RMRS J J 7) J 7) Marks a 1) 2) 3) 4) 5) 6) 7) 8) CE J J J J except CR-PLSx except CR-M...LC except CR-U3E except 125 V DC devices only devices with 4 c/o contacts except CR-U61D, CR-U61DV except 60 V and 125 V devices only relays and sockets with screw terminals 5/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Pluggable interface relays Ordering details - CR-S range Description 2CDC 291 005 F0014 The pluggable interface relays of the CR-S Range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The CR-S Range combines the flexibility of a modular system and the ability of switching high currents on a small footprint thus can be used in applications where space saving is essential. CR-S Ordering details - CR-S range pluggable interface relays Rated control supply voltage 5 V DC 12 V DC 24 V DC 48 V DC 60 V DC 5 V DC 12 V DC 24 V DC 48 V DC 60 V DC Outputs Contact ratings Type 1 c/o (SPDT) standard contacts 250 V, 6 A 1 c/o (SPDT) gold plated contacts 12 V, 250 mA (3W)1) CR-S005VDC1R CR-S012VDC1R CR-S024VDC1R CR-S048VDC1R CR-S060VDC1R CR-S005VDC1RG CR-S012VDC1RG CR-S024VDC1RG CR-S048VDC1RG CR-S060VDC1RG Order code Price 1SVR405501R1010 1SVR405501R2010 1SVR405501R3010 1SVR405501R4010 1SVR405501R5010 1SVR405501R1020 1SVR405501R2020 1SVR405501R3020 1SVR405501R4020 1SVR405501R5020 Pkg Weight (1 pce) qty kg (lb) 10 0.005 (0.011) 10 0.005 (0.011) 5 Ordering details - CR-S range complete interface relays (relay + socket) Rated control supply voltage RS, SS = screw connection type RZ, SZ = spring connection type Outputs Contact ratings 24 V AC/DC 110 V AC/DC 1 c/o (SPDT) standard contacts 250 V, 6A 1 c/o (SPDT) gold plated contacts 12 V, 250 mA (3W)1) 230 V AC/DC 24 V AC/DC 110 V AC/DC 230 V AC/DC 1) Type Order code CR-S024VADC1CRS CR-S024VADC1CRZ CR-S110VADC1CRS CR-S110VADC1CRZ CR-S230VADC1CRS CR-S230VADC1CRZ CR-S024VADC1CRGS CR-S024VADC1CRGZ CR-S110VADC1CRGS CR-S110VADC1CRGZ CR-S230VADC1CRGS CR-S230VADC1CRGZ 1SVR405541R3110 1SVR405541R3210 1SVR405541R6110 1SVR405541R6210 1SVR405541R7110 1SVR405541R7210 1SVR405541R3120 1SVR405541R3220 1SVR405541R6120 1SVR405541R6220 1SVR405541R7120 1SVR405541R7220 Price Pkg Weight (1 pce) qty kg (lb) 10 0.03 (0.066) 10 0.03 (0.066) If specified maximum values exceeded, the gold plating is destroyed. The maximum values of the standard contacts are then valid. Ordering details - CR-S range sockets Rated control supply voltage 6-24 V DC 12-24 V AC/DC 48-60 V AC/DC 110-125 V AC/DC 220-240 V AC/DC Connection type Screw Spring Screw Spring Screw Spring Screw Spring Screw Spring Type Order code CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S220/240VADC1SS CR-S220/240VADC1SZ 1SVR405521R1100 1SVR405521R1200 1SVR405521R3100 1SVR405521R3200 1SVR405521R5100 1SVR405521R5200 1SVR405521R6100 1SVR405521R6200 1SVR405521R7100 1SVR405521R7200 Price Pkg Weight (1 pce) qty kg (lb) 10 0.025 (0.055) Ordering details - CR-S range accessories Version Type Order code Price Pkg Weight (1 pce) qty kg (lb) Jumper bar 20 pole, blue color Jumper bar 20 pole, red color Jumper bar 20 pole, black color CR-SJB20-BLUE CR-SJB20-RED CR-SJB20-BLACK 1SVR405598R0700 1SVR405598R0800 1SVR405598R0900 10 0.008 (0.018) Marker block CR-SM 1SNB041391R0610 10 Separator CR-SSEP 1SVR405599R0000 10 0.0036 (0.0079) 0.012 (0.026) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/8 Pluggable interface relays Ordering details - CR-P range Ordering details - CR-P range 2CDC 291 045 F0004 Rated control supply voltage Contact ratings Order code CR-P012DC1 CR-P024DC1 1SVR405600R4000 1SVR405600R1000 48 V DC CR-P048DC1 1SVR405600R6000 110 V DC CR-P110DC1 1SVR405600R8000 CR-P024AC1 1SVR405600R0000 CR-P048AC1 1SVR405600R5000 120 V AC 230 V AC CR-P110AC1 CR-P120AC1 CR-P230AC1 1SVR405600R7000 1SVR405600R2000 1SVR405600R3000 1 c/o (SPDT) 250 V, 16 A 110 V AC 5 Type 12 V DC 24 V DC 24 V AC 48 V AC CR-P Outputs 12 V DC CR-P012DC2 1SVR405601R4000 24 V DC CR-P024DC2 1SVR405601R1000 48 V DC CR-P048DC2 1SVR405601R6000 110 V DC CR-P110DC2 1SVR405601R8000 CR-P024AC2 CR-P048AC2 CR-P110AC2 1SVR405601R0000 1SVR405601R5000 1SVR405601R7000 120 V AC CR-P120AC2 1SVR405601R2000 230 V AC CR-P230AC2 1SVR405601R3000 24 V DC CR-P024DC2 1SVR405606R1000 24 V AC CR-P024AC2G 1SVR405606R0000 CR-P110AC2G 1SVR405606R7000 CR-P230AC2G 1SVR405606R3000 24 V AC 48 V AC 110 V AC 110 V AC 2 c/o (SPDT) 2 c/o (SPDT) gold contact 250 V, 8 A 250 V, 8 A 230 V AC Price Pkg Weight (1 pce) qty kg (lb) 10 0.014 (0.031) 10 0.014 (0.031) 10 0.014 (0.031) CR-PLS 2CDC 291 006 F0011 Ordering details - Accessories Version Connection terminal Type Order code Logical socket with protective separation 2CDC 291 004 F0007 Pkg Weight (1 pce) qty screw CR-PLS 1SVR405650R0000 screw CR-PLSx 1SVR405650R0100 Logical socket CR-PJ Price Standard socket kg (lb) 0.045 (0.099) 10 0.043 (0.095) spring CR-PLC 1SVR405650R0200 0.042 (0.093) screw CR-PSS 1SVR405650R1000 0.038 (0.084) CR-PH 1SVR405659R0000 Plastic holder for socket 10 Jumper bar for sockets with screw connection CR-PJ 1SVR405658R5000 Marker CR-PM 1SVR405658R0000 5/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 10 0.002 (0.004) 0.018 (0.040) 0.0002 (0.0004) Pluggable interface relays Ordering details - CR-M range Ordering details - CR-M range without LED 2CDC 291 002 F0015 Rated control supply voltage CR-M Outputs Contact ratings Type Order code 12 V DC 24 V DC CR-M012DC2 CR-M024DC2 1SVR405611R4000 1SVR405611R1000 48 V DC CR-M048DC2 1SVR405611R6000 60 V DC CR-M060DC2 1SVR405611R4200 110 V DC CR-M110DC2 1SVR405611R8000 125 V DC CR-M125DC2 250 V, 12 A CR-M220DC2 1SVR405611R8200 1SVR405611R9000 CR-M024AC2 CR-M048AC2 1SVR405611R0000 1SVR405611R5000 CR-M110AC2 1SVR405611R7000 CR-M120AC2 CR-M230AC2 1SVR405611R2000 1SVR405611R3000 24 V DC CR-M012DC3 CR-M024DC3 1SVR405612R4000 1SVR405612R1000 48 V DC CR-M048DC3 1SVR405612R6000 60 V DC CR-M060DC3 1SVR405612R4200 110 V DC CR-M110DC3 1SVR405612R8000 125 V DC CR-M125DC3 250 V, 10 A CR-M220DC3 1SVR405612R8200 1SVR405612R9000 48 V AC CR-M024AC3 CR-M048AC3 1SVR405612R0000 1SVR405612R5000 60 V AC CR-M060AC3 1SVR405612R5200 110 V AC 120 V AC CR-M110AC3 1SVR405612R7000 CR-M120AC3 CR-M230AC3 1SVR405612R2000 1SVR405612R3000 24 V DC CR-M012DC4 CR-M024DC4 1SVR405613R4000 1SVR405613R1000 48 V DC CR-M048DC4 1SVR405613R6000 60 V DC CR-M060DC4 1SVR405613R4200 110 V DC CR-M110DC4 1SVR405613R8000 125 V DC CR-M125DC4 CR-M220DC4 1SVR405613R8200 1SVR405613R9000 CR-M024AC4 CR-M048AC4 1SVR405613R0000 1SVR405613R5000 CR-M110AC4 1SVR405613R7000 CR-M120AC4 CR-M230AC4 1SVR405613R2000 1SVR405613R3000 220 V DC 2 c/o (SPDT) 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 220 V DC 3 c/o (SPDT) 24 V AC 230 V AC 12 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 4 c/o (SPDT) 250 V, 6 A Price Pkg Weight (1 pce) qty kg (lb) 10 0.033 (0.073) 5 10 0.033 (0.073) 10 0.033 (0.073) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/10 Pluggable interface relays Ordering details - CR-M range Ordering details - CR-M range with LED Rated control supply voltage Outputs Contact ratings 2CDC 291 002 F0015 12 V DC 5 Order code 24 V DC CR-M012DC2L CR-M024DC2L 1SVR405611R4100 1SVR405611R1100 48 V DC CR-M048DC2L 1SVR405611R6100 60 V DC CR-M060DC2L 1SVR405611R4300 110 V DC 125 V DC CR-M110DC2L 1SVR405611R8100 CR-M125DC2L 1SVR405611R8300 CR-M220DC2L 1SVR405611R9100 48 V AC CR-M024AC2L CR-M048AC2L 1SVR405611R0100 1SVR405611R5100 110 V AC CR-M110AC2L 1SVR405611R7100 120 V AC CR-M120AC2L 1SVR405611R2100 230 V AC CR-M230AC2L 1SVR405611R3100 12 V DC 24 V DC CR-M012DC3L CR-M024DC3L 1SVR405612R4100 1SVR405612R1100 48 V DC CR-M048DC3L 1SVR405612R6100 60 V DC CR-M060DC3L 1SVR405612R4300 110 V DC 125 V DC CR-M110DC3L 1SVR405612R8100 CR-M125DC3L 1SVR405612R8300 CR-M220DC3L 1SVR405612R9100 48 V AC CR-M024AC3L CR-M048AC3L 1SVR405612R0100 1SVR405612R5100 110 V AC CR-M110AC3L 1SVR405612R7100 120 V AC CR-M120AC3L 1SVR405612R2100 230 V AC CR-M230AC3L 1SVR405612R3100 12 V DC 24 V DC CR-M012DC4L CR-M024DC4L 1SVR405613R4100 1SVR405613R1100 48 V DC CR-M048DC4L 1SVR405613R6100 60 V DC CR-M060DC4L 1SVR405613R4300 110 V DC CR-M110DC4L 1SVR405613R8100 125 V DC 220 V DC CR-M125DC4L 1SVR405613R8300 CR-M220DC4L 1SVR405613R9100 48 V AC CR-M024AC4L CR-M048AC4L 1SVR405613R0100 1SVR405613R5100 110 V AC CR-M110AC4L 1SVR405613R7100 120 V AC CR-M120AC4L 1SVR405613R2100 230 V AC CR-M230AC4L 1SVR405613R3100 220 V DC CR-M Type 2 c/o (SPDT) 250 V, 12 A 24 V AC 220 V DC 3 c/o (SPDT) 250 V, 10 A 24 V AC 4 c/o (SPDT) 250 V, 6 A 24 V AC Price Pkg Weight (1 pce) qty kg (lb) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) Ordering details - CR-M range with LED and free-wheeling diode Rated control supply voltage 24 V DC Outputs 4 c/o (SPDT) Contact ratings Type 250 V, 6 A CR-M024DC4LD Order code Price 1SVR405614R1100 Pkg Weight (1 pce) qty kg (lb) 10 0.033 (0.073) Ordering details - CR-M range with gold contacts Rated control supply voltage Outputs Contact ratings Type Order code 24 V DC CR-M024DC4G 1SVR405618R1000 24 V AC CR-M024AC4G 250 V, 6 A CR-M110AC4G 1SVR405618R0000 1SVR405618R7000 CR-M230AC4G 1SVR405618R3000 110 V AC 4 c/o (SPDT), gold contacts 230 V AC 5/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Price Pkg Weight (1 pce) qty kg (lb) 10 0.033 (0.073) Pluggable interface relays Ordering details - CR-M range Ordering details – CR-M range with gold contacts and LED Rated control supply voltage Outputs Contact ratings 2CDC 291 002 F0015 12 V DC Order code 24 V DC CR-M012DC4LG CR-M024DC4LG 1SVR405618R4100 1SVR405618R1100 48 V DC CR-M048DC4LG 1SVR405618R6100 60 V DC CR-M060DC4LG 1SVR405618R4300 110 V DC CR-M110DC4LG 1SVR405618R8100 CR-M125DC4LG CR-M220DC4LG 1SVR405618R8300 1SVR405618R9100 48 V AC CR-M024AC4LG CR-M048AC4LG 1SVR405618R0100 1SVR405618R5100 110 V AC CR-M110AC4LG 1SVR405618R7100 120 V AC CR-M120AC4LG CR-M230AC4LG 1SVR405618R2100 1SVR405618R3100 125 V DC 220 V DC CR-M Type 24 V AC 4 c/o (SPDT) with gold contacts and LED 250 V / 6A 230 V AC Price Pkg Weight (1 pce) qty kg (lb) 10 0.033 (0.073) 10 0.033 (0.073) Ordering details – CR-M range with gold contacts, LED and free-wheeling diode Rated control supply voltage 12 V DC 24 V DC Outputs Contact ratings 4 c/o (SPDT) with gold contacts, LED and free-wheeling diode Type CR-M012DC4LDG Order code Price Pkg Weight (1 pce) qty kg (lb) 10 0.033 (0.073) 1SVR405618R4400 CR-M024DC4LDG 1SVR405618R1400 Type Order code Ordering details - Accessories Version Connection terminal Price Pkg Weight (1 pce) 2CDC 291 009 F0011 qty Logical socket for 2 c/o CR-M2LS 1SVR405651R1100 CR-M3LS 1SVR405651R2100 CR-M4LS 1SVR405651R3100 CR-M2LC 1SVR405651R1200 CR-M4LC 1SVR405651R3200 CR-M2SS 1SVR405651R1000 CR-M3SS 1SVR405651R2000 CR-M4SS 1SVR405651R3000 CR-M2SF 1SVR405651R1300 CR-M4SF 1SVR405651R3300 Plastic holder CR-MH 1SVR405659R1000 10 Metal holder CR-MH1 1SVR405659R1100 10 Jumper bar for sockets with screw connection CR-MJ 1SVR405658R6000 10 Marker CR-MM 1SVR405658R1000 10 Logical socket for 3 c/o screw Logical socket for 2/4 c/o CR-M4SS Logical socket for 2 c/o Logical socket for 2/4 c/o spring CR-MJ 2CDC 291 005 F0007 Standard socket for 2 c/o Standard socket for 3 c/o screw Standard socket for 2/4 c/o Standard socket for 2 c/o Standard socket for 2/4 c/o fork type 10 10 10 10 kg (lb) 0.055 (0.121) 0.062 (0.137) 0.066 (0.146) 0.065 (0.143) 0.066 (0.146) 0.066 (0.146) 0.068 (0.150) 0.070 (0.154) 0.040 (0.088) 0.048 (0.106) 0.003 (0.007) 0.0005 (0.001) 0.029 (0.064) 0.0005 (0.001) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/12 5 Pluggable interface relays Ordering details CR-P/M functional modules Ordering details - CR-P/M range (all products stocked) 2CDC 291 005 S0011 Rated control supply voltage CR-P/M ... Version Type Order code Price Pkg Weight (1 pce) qty kg (lb) 6-220 V DC 6-24 V DC 24-60 V DC 110-230 V DC Diode Reverse polarity protection/free wheeling diode Diode and LED - Reverse polarity protection/free wheeling diode A1+, A2- CR-P/M 22 1SVR405651R0000 red, A1+, A2- CR-P/M 42 1SVR405652R0000 green, A1+, A2- CR-P/M 42V CR-P/M 42B red, A1+, A2- 24-60 V AC/DC 110-230 V AC/DC 1SVR405652R4100 red, A1+, A2- CR-P/M 42C 1SVR405652R9000 green, A1+, A2- CR-P/M 42CV 1SVR405652R9100 CR-P/M 52B 1SVR405653R0000 CR-P/M 52D 1SVR405653R4000 CR-P/M 52C 1SVR405653R1000 CR-P/M 62 1SVR405654R0000 CR-P/M 62V 1SVR405654R1000 CR-P/M 62E 1SVR405654R4000 CR-P/M 62EV 1SVR405654R4100 CR-P/M 92 1SVR405654R0100 CR-P/M 92V 1SVR405654R1100 CR-P/M 62C 1SVR405655R0000 CR-P/M 62CV 1SVR405655R1000 CR-P/M 62D 1SVR405655R4000 Spark quenching 6-24 V AC/DC 24-60 V AC/DC Diode, LED and reverse polarity protection 110 V DC 110-230 V AC 6-24 V AC/DC 24-60 V AC/DC Varistor and LED Overvoltage protection 110 V DC 110-230 V AC 24 V AC 115 V AC 230 V AC 1SVR405652R4000 CR-P/M 42BV 6-24 V AC/DC red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2- Overvoltage protection 10 0.003 (0.007) 10 0.003 (0.007) 10 0.003 (0.007) 10 0.003 (0.007) 10 0.003 (0.007) 10 0.002 (0.004) 1SVR405652R1000 green, A1+, A2- CR-P/M 62DV 1SVR405655R4100 CR-P/M 92C 1SVR405655R0100 CR-P/M 92CV 1SVR405655R1100 CR-P/M 72 1SVR405656R0000 CR-P/M 72A 1SVR405656R1000 CR-P/M 82 1SVR405656R2000 2CDC 292 013 F0005 2CDC 292 014 F0005 2CDC 292 015 F0005 Connection diagrams CR-P/M 42, CR-P/M 42B, CR-P/M 52B, CR-P/M 52C CR-P/M 42C, CR-P/M 42V, CR-P/M 52D, CR-P/M 42BV, CR-P/M 42CV CR-P/M 62, CR-P/M 62E, CR-P/M 92, CR-P/M 62V, CR-P/M 62EV, CR-P/M 92V 2CDC 292 017 F0005 2CDC 292 018 F0005 CR-P/M 22 2CDC 292 016 F0005 5 Description CR-P/M 62C, CR-P/M 62D, CR-P/M 72, CR-P/M 82 CR-P/M 92C, CR-P/M 62CV, CR-P/M 72A, CR-P/M 62DV CR-P/M 92CV 5/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Pluggable interface relays Ordering details - CR-U range Description 2CDC 291 047 F0004 Interface relays are widely used in various industrial applications: As an interface they link the electronic controlling, e.g. PLC (programmable logic controller), PC or field bus systems, to the sensor / actuator level. Here, they take on various functions: Switching of AC or DC loads with different resistive, inductive and capacitive parts, switching voltages from a few mV up to 250 V, switching currents from a few mA up to 16 A, amplification of weak control signals, electrical isolation of control and load circuits, and signal multiplying. In contrast to electronic switching devices, interface relays don’t use additional internal protective circuits and thus are overload-proof against short-time variations like current or voltage peaks. CR-U Ordering details - CR-U range 2CDC 291 007 S0011 Rated control supply voltage 12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC Outputs Contact ratings 2 c/o without LED 250 V, 10 A 3 c/o without LED 250 V, 10 A 2 c/o with LED 250 V, 10 A 3 c/o with LED 250 V, 10 A Type CR-U012DC2 CR-U024DC2 CR-U048DC2 CR-U110DC2 CR-U220DC2 CR-U024AC2 CR-U048AC2 CR-U110AC2 CR-U120AC2 CR-U230AC2 CR-U012DC3 CR-U024DC3 CR-U048DC3 CR-U110DC3 CR-U125DC3 CR-U220DC3 CR-U024AC3 CR-U048AC3 CR-U060AC3 CR-U110AC3 CR-U120AC3 CR-U230AC3 CR-U012DC2L CR-U024DC2L CR-U048DC2L CR-U110DC2L CR-U220DC2L CR-U024AC2L CR-U048AC2L CR-U110AC2L CR-U120AC2L CR-U230AC2L CR-U012DC3L CR-U024DC3L CR-U048DC3L CR-U110DC3L CR-U220DC3L CR-U024AC3L CR-U048AC3L CR-U110AC3L CR-U120AC3L CR-U230AC3L Order code Price 1SVR405621R4000 1SVR405621R1000 1SVR405621R6000 1SVR405621R8000 1SVR405621R9000 1SVR405621R0000 1SVR405621R5000 1SVR405621R7000 1SVR405621R2000 1SVR405621R3000 1SVR405622R4000 1SVR405622R1000 1SVR405622R6000 1SVR405622R8000 1SVR405622R8200 1SVR405622R9000 1SVR405622R0000 1SVR405622R5000 1SVR405622R5200 1SVR405622R7000 1SVR405622R2000 1SVR405622R3000 1SVR405621R4100 1SVR405621R1100 1SVR405621R6100 1SVR405621R8100 1SVR405621R9100 1SVR405621R0100 1SVR405621R5100 1SVR405621R7100 1SVR405621R2100 1SVR405621R3100 1SVR405622R4100 1SVR405622R1100 1SVR405622R6100 1SVR405622R8100 1SVR405622R9100 1SVR405622R0100 1SVR405622R5100 1SVR405622R7100 1SVR405622R2100 1SVR405622R3100 Pkg Weight (1 pce) qty kg (lb) 10 0.083 (0.183) 10 0.083 (0.183) 10 0.083 (0.183) 10 0.083 (0.183) Ordering details - Accessories Version Type Order code CR-U2S Socket for 2 c/o and module Socket for 3 c/o and module Socket for 3 c/o CR-U2S CR-U3S CR-U3E 1SVR405670R0000 1SVR405660R0000 1SVR405660R0100 Socket small for 2 c/o CR-U2SM 1SVR405670R1100 Socket small for 3 c/o CR-U3SM 1SVR405660R1100 Holder for CR-U socket CR-UH 1SVR405669R0000 Price Pkg Weight (1 pce) qty kg (lb) 10 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/14 5 Pluggable interface relays Ordering details - CR-U accessories Ordering details - CR-U range (all products stocked) 6-24 V DC CR-U... 24-60 V DC 110 V DC 5 Diode Reverse polarity protection/ free wheeling diode Diode and LED - Reverse polarity protection/ free wheeling diode 6-24 V AC/DC Version 24-60 V AC/DC Diode and LED 110 V DC 110230 V AC 6-24 V AC/DC Varistor and 24-60 V AC/DC LED Overvoltage protection 2CDC 291 032 F0005 110 V DC 110230 V AC CR-U T 24 V AC 230 V AC Overvoltage protection, varistor 24-240 V AC/DC Multifunction time module 115 V AC Order code A1+, A2- CR-U 21 1SVR405661R0000 red, A1+, A2- CR-U 41 1SVR405662R0000 green, A1+, A2- CR-U 41V CR-U 41B red, A1+, A2- 1SVR405662R1000 green, A1+, A2- CR-U 41BV CR-U 41C red, A1+, A2- 1SVR405662R4100 green, A1+, A2- CR-U 41CV CR-U 51B 1SVR405662R9100 24-60 V AC/DC Spark quenching 110-230 V AC/DC 6-24 V AC/DC Type red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2- pluggable onto CR-U2S and CR-U3S 1SVR405662R4000 Price Pkg Weight (1 pce) qty kg (lb) 10 0.007 (0.015) 10 0.007 (0.015) 10 0.007 (0.015) 10 0.007 (0.015) 10 0.007 (0.015) 10 0.007 (0.015) 10 0.014 (0.031) 1SVR405662R9000 1SVR405663R0000 CR-U 51D 1SVR405663R4000 CR-U 51C 1SVR405663R1000 CR-U 61 1SVR405664R0000 CR-U 61V 1SVR405664R1000 CR-U 61E 1SVR405664R4000 CR-U 61EV 1SVR405664R4100 CR-U 91 1SVR405664R0100 CR-U 91V 1SVR405664R1100 CR-U 61C 1SVR405665R0000 CR-U 61CV 1SVR405665R1000 CR-U 61D 1SVR405665R4000 CR-U 61DV 1SVR405665R4100 CR-U 91C 1SVR405665R0100 CR-U 91CV 1SVR405665R1100 CR-U 71 1SVR405666R0000 CR-U 71A CR-U 81 1SVR405666R1000 CR-U T 1SVR405667R0000 1SVR405666R2000 All CR-U modules can be plugged onto sockets CR-U2S and CR-U3S. 2CDC 292 013 F0005 2CDC 292 014 F0005 Connection diagrams 2CDC 292 015 F0005 6-220 V DC Description CR-U 41, CR-U 41B, CR-U 41C, CR-U 41V, CR-U 41BV, CR-U 41CV CR-U 61, CR-U 61E, CR-U 91, CR-U 61V, CR-U 61EV, CR-U 91V 2CDC 292 017 F0005 2CDC 292 016 F0005 CR-U 21 CR-U 61C, CR-U 61CV, CR-U 61D, CR-U 61DV, CR-U 91C, CR-U 91CV 5/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CR-U 51B, CR-U 51C CR-U 51D 2CDC 292 018 F0005 2CDC 291 004 S0011 Rated control supply voltage CR-U 71, CR-U 71A , CR-U 81 Pluggable interface relays Technical data - CR-P, CR-M, CR-U Input circuit - coil data CR-P range Rated control Rated supply frequency voltage US Make voltage MaximumBreak (at 20 °C) voltage (at 55 voltage °C) Rated power Coil resistance (at 20 °C) Tolerance of coil resistance DC coils 12 V DC 24 V DC 48 V DC 110 V DC 8.4 V DC 16.8 V DC 33.6 V DC 77 V DC 30.6 V DC 61.2 V DC 122.4 V DC 280 V DC 0.4-0.48 0.4-0.48 0.4-0.48 0.4-0.48 360 1440 5700 25200 AC coils 24 V AC 48 V AC 50 / 60 Hz 50 / 60 Hz 19.2 V AC 38.4 V AC 28.8 V AC 57.6 V AC 110 V AC 120 V AC 230 V AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz - 0.1 0.1 0.1 0.1 US US US US W W W W 10% 10% 10% 10% 0.15 U S 0.15 U S 0.75 VA 0.75 VA 400 1550 10% 10% 0.15 U S 0.15 U S 0.15 U S 0.75 VA 0.75 VA 0.75 VA 8900 10200 38500 10% 10% 10% Make voltage Maximum Break (at 20 °C) voltage (at 55 voltage °C) Rated power Coil resistance (at 20 °C) Tolerance of coil resistance 88 V AC 96 V AC 184 V AC 132 V AC 144 V AC 276 V AC CR-M range Rated control Rated supply frequency voltage US DC coils AC coils 12 V DC 24 V DC 48 V DC - 9.6 V DC 19.2 DC 38.4 V DC 60 V DC 110 V DC 125 V DC - 220 V DC - 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC 50 50 50 50 50 50 / / / / / / 60 60 60 60 60 60 Hz Hz Hz Hz Hz Hz 13.2 V DC 26.4 V DC 52.8 V DC 0.1 U S 0.1 U S 0.1 U S 0.9 W 0.9 W 0.9 W 160 640 2600 10% 10% 10% 48 V DC 88 V DC 100 V DC 66 V DC 121 V DC 137.5 V DC 0.1 U S 0.1 U S 0.1 U S 0.9 W 0.9 W 0.9 W 4000 13600 16000 10% 10% 10% 176 V DC 242 V DC 0.1 U S 0.9 W 54000 10% 26.4 V AC 52.8 V AC 66 V AC 121 V AC 132 V AC 253 V AC 1.6 1.6 1.6 1.6 1.6 1.6 158 640 930 3450 3770 16100 19.2 V AC 38.4 V AC 48 V AC 88 V AC 96 V AC 184 V AC 0.2 0.2 0.2 0.2 0.2 0.2 US US US US US US VA VA VA VA VA VA 10% 10% 10% 10% 10% 10% CR-U range Rated control Rated supply frequency voltage US Make voltage Maximum Break (at 20 °C) voltage (at 55 voltage °C) Rated power Coil resistance (at 20 °C) Tolerance of coil resistance DC coils 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC - 9.6 V DC 19.2 V DC 38.4 V DC 88.0 V DC 100 V DC 176.0 V DC 13.2 V DC 26.4 V DC 52.8 V DC 121.0 V DC 137.5 V DC 242.0 V DC 1.5 1.5 1.5 1.5 1.5 1.5 W W W W W W 110 430 1750 9200 11000 37000 AC coils 24 V AC 50 / 60 Hz 19.2 V AC 26.4 V AC 0.15 U S 10 % 50 / 60 Hz 38.4 V AC 52.8 V AC 0.15 U S 305 10 % 60 V AC 50 / 60 Hz 48.0 V AC 66.0 V AC 0.15 U S 475 10 % 110 V AC 50 / 60 Hz 88.0 V AC 121.0 V AC 0.15 U S 1700 10 % 120 V AC 50 / 60 Hz 96.0 V AC 132.0 V AC 0.15 U S 1910 10 % 230 V AC 50 / 60 Hz 184.0 V AC 253.0 V AC 0.15 U S VA VA VA VA VA VA VA VA VA VA VA VA 75 48 V AC 2.8 2.5 2.8 2.5 2.8 2.5 2.8 2.5 2.8 2.5 2.8 2.5 7080 10 % 0.1 0.1 0.1 0.1 0.1 0.1 Us Us Us Us Us Us (50 (60 (50 (60 (50 (60 (50 (60 (50 (60 (50 (60 Hz) Hz) Hz) Hz) Hz) Hz) Hz) Hz) Hz) Hz) Hz) Hz) 10 10 10 10 10 10 % % % % % % 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/16 5 Pluggable interface relays Technical data - CR-P, CR-M, CR-U CR-P...1 Type Output circuit(s) 11-12/14 Kind of output Relay, 1 c/o Contact material AgNi Rated operational voltage U e (VDE 0110, IEC 60947-1) 250 V Minimum switching voltage Maximum switching voltage 5 CR-P...2 CR-M...2 CR-M...3 11-12/14 21-22/24 11-12/14 21-22/24 11-12/14 21-22/24 31-32/34 Relay, 2 c/o AgNi AgNi/Au 5 µm Relay, 2 c/o Relay, 3 c/o AgNi AgNi 5V 10 V (AgNi) DC 300 V DC 250 V DC AC CR-M...4 11-12/14 21-22/24 31-32/34 41-42/44 Relay, 4 c/o AgNi AgNi/Au 5 µm 5 V (AgNi/Au) CR-U...2 11-12/14 31-32/34 11-12/14 21-22/24 31-32/34 Relay, 2 c/o Relay, 3 c/o AgNi 10 V 440 V AC 250 V AC Minimum switching current 5 mA (AgNi), 2 mA (AgNi/Au) 5 mA (AgNi) 5 mA (AgNi) 2 mA (AgNi/Au) 5 mA Rated free air thermal current I th AC-12 (resistive) 230 V Rated AC-15 (inductive) 230 V o perational AC-15 (inductive) 120 V current (IEC 60947DC-12 (resistive) 24 V 5-1) DC-13 (inductive) 24 V DC-13 (inductive) 120 V DC-13 (inductive) 250 V AC rating Utilization category (pilot duty) (Contact rating code designation) (UL 508) max. rated operational voltage 16 A 16 A 1.5 A 3A 16 A 2.5 A 0.22 A 0.1 A 8A 8A 1.5 A 12 A 12 A 1.5 A 10 A 10 A 1.5 A 8A 2A 12 A 2.5 A 10 A 2.5 A 6A 6A 1A 1.5 A 6A 2A 10 A 10 A 1.5 A 3A 10 A 2A 440 V AC B300 B300 B300 300 V AC 300 V AC 300 V AC Max. continuous thermal current at utilization category 5A 5A Max. making / breaking apparent power at utilization category 3600 / 360 VA 3600 / 360 VA Utilization category (resistive) (CSA22.2 No.14....) DC rating * (UL 508; NEMA ICS-5) Utilization category (pilot duty) (Contact rating code designation) Max. rated operational voltage Max. continuous thermal current at utilization category Max. making / breaking apparent power at utilization category Utilization category (resistive) (CSA22.2 No.14....) 16 A, 250 V AC 8 A, 250 V AC 10 A, 250 V AC 12 A, 150 V AC 5A 6 A, 250 V AC 10 A, 150 V AC 2.5 A 5A 1800 / 180 VA 3600/360 VA 5 A, 250 V AC 10 A, 150 V AC 10 A, 250 V AC (resistive + single-phase) R300 300 V DC 1A 28 VA - 10 A, 24 V DC - Maximum making (inrush) current 30 A 15 A Minimum switching power 0.3 W (AgNi), 0.05 W (AgNi/Au) 0.3 W (AgNi), 0.1 W (AgNi/Au) 0.3 W 4000 VA 3000 VA 2500 VA Maximum switching (breaking) power AC1 (resistive) Contact resistance CR-U...3 2000 VA 24 A 10 A, 28 V DC 20 A 2500 VA 12 A 1500 VA 20 A 100 m 600 switching cycles/h 1200 switching cycles/h 72000 switching cycles/h 18000 switching cycles/h > 3 x 107 switching cycles > 0.7 x 10 5 > 10 5 switching switching cycles (16 A, cycles (8 A, 250 V) 250 V) see reduction factor F > 2 x 107 switching cycles > 10 5 switching cycles (12 A, 250 V) (10 A, 250 V) (6 A, 250 V) > 10 5 switching cycles (12 A, 250 V) Response time typ. 7 ms typ. 13 ms (DC),10 ms (AC) typ. 18 ms (DC), 12 ms (AC) Release time typ. 3 ms typ. 3 ms (DC), 8 ms (AC) typ. 7 ms (DC), 10 ms (AC) Isolation data Rated insulation voltage 400 V AC 250 V AC Insulation class C250 / B400 C250 / B250 between coil and contacts 5 kV AC 2.5 kV AC between open contacts 1 kV AC 1.5 kV AC Maximum operating frequency rated load AC-1 without load Mechanical lifetime Electrical lifetime electrical AC1 (resistive) cos ϕ Rated impulse withstand voltage U imp between c/o (SPDT) contacts - 2.5 kV AC 12000 switching cycles/h C250 2.5 kV AC 2 kV AC 2 kV AC Clearance between coil and contacts 10 mm 2.5 mm 1.6 mm 3 mm Creepage distancebetween coil and contacts Overvoltage category 10 mm III 4 mm III 3.2 mm II 4.2 mm III Pollution degree 3 3 2 3 * Those ratings are based on different type tests but they are not covered by the cULus or CSA approvals. 5/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Pluggable interface relays Technical data, load limit curves - CR-P, CR-M, CR-U CR-P...1 Type CR-P...2 CR-M...2 CR-M...3 CR-M...4 CR-U...2 CR-U...3 General data Dimensions (W x H x D) when mounted 12.7 x 29 x 15.7 mm 21.2 x 27.5 x 35.6 mm 35 x 35 x 54.4 mm Weight 14 g (0.031 lb) 35 g (0.077 lb) 83 g (0.18 lb) Mounting on socket (see accessories) Mounting position any Degree of protection IP 67 Electrical connection Connection by socket IP 40 Environmental data Ambient temperature range operation Vibration resistance 10-150 Hz n/o contact 10 g 5g 5g n/c contact 10 g 5g 5g 5g Shock resistance n/o contact 30 g 20 g 10 g 10 g n/c contact 30 g 20 g 5g 10 g IEC/EN 60255-23, IEC/EN 60810-1, IEC/EN 61810-7 IEC/EN 60255-1 storage Standards Product standard DC: -40...+85 °; AC: -40...+70 °C DC: -40...+70 °; AC: -40...+55 °C -40 ... +85 °C IEC/EN 60255-23, IEC/EN 60664-1, IEC/EN 61810-1 Low Voltage Directive 5 2006/95/EC Approvals see page 5/6. Load limit curves - Maximum switching power at resistive DC load CR-U with 2 and 3 c/o contacts DC current [A] 2 = inductive load, T = 40 ms DC voltage [V] 2CDC 292 023 F0204 1 = resistive load, T = 0 ms DC voltage [V] DC voltage [V] CR-M with 4 c/o contacts 2CDC 292 019 F0204 2CDC 292 015 F0204 DC current [A] DC voltage [V] 2 = inductive load, T = 40 ms DC current [A] CR-M with 3 c/o contacts DC current [A] CR-M with 2 c/o contacts DC voltage [V] 2CDC 292 010 F0204 2CDC 292 005 F0204 DC current [A] DC voltage [V] 1 = resistive load, T = 0 ms 2CDC 292 028 F0204 CR-P with 2 c/o contacts DC current [A] CR-P with 1 c/o contact 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/18 Pluggable interface relays Technical data - Sockets for CR-P and CR-M Output circuits Output circuits Number of poles Rated voltage CR-PLS CR-PLS(x) 11-12/14, 21-22/24 2 250 V AC 300 V AC 250 V AC CR-MxLS CR-MxSS 11-12/14, 21-22/24, ... 2, 3 or 4 250 V AC Rated current 2 x 10 A1) 2 x 12 A1) 2 x 10 A1) 7A 76 x 15.8 x 62 mm (2.992 x 0.622 x 2.441 in) 78.5 x 15.5 x 61 mm (3.011 x 0.610 x 2.402 in) 76 x 15.8 x 42.8 mm (2.992 x 0.622 x 1.685 in) General data Dimensions without holder and module (L x W x H) Degree of protection Temperature range Connection type 5 terminals IP 20 B (EN 60529) operation -40...+70 °C -40...+85 °C storage -40...+70 °C -40...+85 °C screw connection Maximum number of wires per connecting terminal Wire size CR-PSS -40...+70 °C -40...+70 °C 2 97.5 x 16.3 x 45.2 mm (3.839 x 0.642 x 1.780 in) spring connection 2 (one per connection point) rigid 75 x 27.2 x 60.8 mm (2.952 x 1.071 x 2.394 in) with wire end ferule Stripping length Tightening torque Maximum with 0.2 mm 2 clamping with 1.5 mm 2 force with wire end ferrule Mounting Material socket contacts contact surface terminals combi screw M3 Isolation data Insulation voltage Isolation between coil and contacts 2 x 1.5 mm 2 (2 x 16 AWG) 0.6 Nm 0.8 Nm DIN rail (IEC/EN 60715) PA 6+GF - V2 CuZn33 5 μ Ni 5 μ tinned 8 μ Ni 8 μ galvanized 8.8 Steel, 5μ Ni 75.2 x 27.2 x 42.6 mm (2.961 x 1.071 x 1.677 in) -40...+70 °C -40...+70 °C screw connection 2 Clearance and creepage distance EN 61984 Standards Products standard Low Voltage Directive EMC Directive EN 61984 2006/95/EC - > 5 kV EN 61984 > 3 kV 0.2-1.5 mm 2 (24-16 AWG) 0.6 Nm - 5 μ Ni 8 μ Ni > 5 kV 10 N 40 N XCrNi Steel - VDE 0106 / 101 DIN EN 60664-1 Loads >10 A ( >12 A for CR-PLSx) require jumpering of terminal 11 with 21, 12 with 22, and 14 with 24 5/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 CR-MxSF 2 or 4 CR-MxLC 300 V AC 10 A 2 x 2.5 mm 2 (2 x 14 AWG) fine-strand 2 x 2.5 mm 2 (2 x 14 AWG) 1) CR-PLC 2 x 1.5 mm 2 (2 x 16 AWG) 7 mm (0.28 in) 0.6 Nm (5.31 lb.in) - 66.7 x 30.3 x 29 mm (2.626 x 1.193 x 1.142 in) 95 x 31 x 42.5 mm (3.74 x 1.22 x 1.67 in) -25...+85 °C fork type screw - spring connection 2 (one per connection point) 2 x 1.5 mm 2 0.2 - 1.5 mm 2 (2 x 16 AWG) (24 x 16 AWG) - - - 10 N 40 N > 40 N PA 6+GF - V2 CuZn33 5 μ Ni 8 μ Ni 8.8 Steel, 5μ Ni 6 μ Ni 5 μ tinned CCSC - > 3 kV EN 61984 > 4 kV - EN 61984 EN 61984 2006/95/EC 2004/108/EC DIN EN 61140, VDE 0140-1 DIN EN 60664-1 - - Pluggable interface relays Technical data - Sockets for CR-U Output circuits Output circuits Number of poles Rated voltage CR-U2S 11-12/14, 21-22/24,... 2 250 V AC Rated current 10 A General data Dimensions without holder and module (L x W x H) Degree of protection terminals Temperature range operation storage Wire size rigid 75.3 x 37.3 x 26 mm (2.965 x 1.469 x 1.024 in) IP 20 B (EN 60529) -40...+70 °C -40...+70 °C 2 x 2.5 mm 2 (2 x 14 AWG) fine-strand with wire end ferule Tightening torque Mounting Material socket contacts contact surface terminals combi screw M3 Isolation data Insulation voltage Isolation between coil and contacts Clearance and creepage distance Standards Products standard Low Voltage Directive 2 x 2.5 mm 2 (2 x 14 AWG) 2 x 1.5 mm 2 (2 x 16 AWG) 0.6 Nm DIN rail (IEC/EN 60715) PA 6+GF - V2 CuZn33 6 μ Ni 8 μ Ni 8.8 Steel, 5μ Ni CR-U3S 3 75.3 x 38.1 x 26 mm (2.965 x 1.500 x 1.024 in) CR-U3E CR-UxSM 300 V AC 2 or 3 250 V 70 x 38 x 26 mm (2.756 x 1.496 x 1.024 in) 61.8 x 38.1 x 26 mm (2.756 x 1.500 x 1.024 in) -40...+85 °C -40...+85 °C -40...+70 °C -40...+70 °C 0.8 Nm 0.6 Nm 8 μ galvanized 3 μ Ni 10 μ Ni Steel, 8 μ Ni > 2 kV EN 61984 EN 61984 EN 61984: 2001 2006/95/EC 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/20 5 Pluggable interface relays Technical data - CR-S range Rated control supply voltage Us Make voltage (at 23 °C) Maxium voltage (at 55 °C) Break voltage Rated power Coil resistance (at 23 °C) Tolerance of coil resistance CR-S005VDC1R(G) 5 V DC 3.75 V DC 7.5 V DC 0.25 V DC 170 mW 147 Ω ± 10 % CR-S012VDC1R(G) 12 V DC 9 V DC 18 V DC 0.6 V DC 170 mW 848 Ω ± 10 % CR-S024VDC1R(G) 24 V DC 18 V DC 36 V DC 1.2 V DC 170 mW 3390 Ω ± 15 % CR-S048VDC1R(G) 48 V DC 36 V DC 72 V DC 2.4 V DC 210 mW 10600 Ω ± 15 % CR-S060VDC1R(G) 60 V DC 45 V DC 90 V DC 3 V DC 210 mW 16600 Ω ± 15 % Output circuits 5 Output circuits Kind of output Contact material 11-12/14 1 c/o (SPDT) AgSnO 2 / AgSnO 2 /Au Rated operational voltage U e (IEC/EN 60947-1) 250 V AC Minimum switching voltage Maximum switching voltage Minimum switching current 12 V DC 400 V AC / 125 V DC 100 mA (AgSnO 2) / 10 mA (AgSnO 2 /Au) Rated free air thermal current I th Rated operational current (IEC/EN 60947-5-1) AC rating (UL 508; NEMA ICS-5) DC rating (UL 508; NEMA ICS-5) Maximum making (inrush) current Minimum switching power Maximum switching (breaking) power Contact resistance Maximum operating frequency Mechanical lifetime Electrical lifetime Response time Release time Isolation data Rated insulation voltage Rated impulse withstand voltage Uimp Clearance Creepage distance Overvoltage category Pollution degree General data Dimensions (W x H x D) Weight Mounting Mounting position Degree of protection Electrical connection Connection Environmental data Ambient temperature range Vibration resistance (10-150 Hz) Shock resistance Standards Product standard Low Voltage Directive 5A AC12 (resistive) 230 V AC15 (inductive) 230 V AC15 (inductive) 120 V DC12 (resistive) 24 V DC13 (inductive) 24 V DC13 (inductive) 120 V DC13 (inductive) 250 V Utilization category (pilot duty) (Contact rating code designation) Utilization category (pilot duty) (Contact rating code designation) 6A 1.5 A 3A 6A 1A 0.22 A 0.11 A B300 R300 15 A, 240 V AC 100 mA/12 V (AgSnO 2) / 50 mW (AgSnO 2 /Au) AC1 (resistive) 1500 VA, 250 V AC 100 mW (at 1 A/ 6 V DC) rated load AC1 360 switching cycles/h without load 18000 switching cycles/h 1 x 107 switching cycles AC1 (resistive) (n/c) 3 x 10 4 switching cycles (at +85 °C) (n/o) 1 x 10 4 switching cycles (at +85 °C) 8 ms 4 ms 250 V AC between coil and contacts 4000 V AC 1 min between open contacts 1000 V AC 1 min between coil and contacts 5.5 mm (0.217 in) between coil and contacts 8 mm (0.315 in) III 2 28 x 5 x 15 mm (1.102 x 0.196 x 0.590 in) 5 g (0.011 lb) on socket any RT II and RT III by socket operation storage n/o contact n/c contact n/o contact n/c contact 5/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 -40...+85 °C 0...+40 °C 10 Hz to 55 Hz 1mm DA 10 Hz to 55 Hz 1mm DA Functional 49 m/s ² / Destructive 980 m/s ² Functional 49 m/s ² / Destructive 980 m/s ² IEC 61810-1 2006/95/EC Pluggable interface relays Technical data - CR-S range sockets Input circuits CR-S 6-24 V CR-S 12-24 V CR-S 48-60 V CR-S 110-125 V Rated control supply voltage U s 6-24 V DC 2-24 V AC/DC 48-60 V AC/DC 110-125 V AC/DC 220-240 V AC/DC Rated control supply voltage U s tolerance (0.8-1.2) U n (0.8-1.1) U n Typical current Response time Release time Status device Protective circuit Output circuits 11-29 mA 8 ms 4 ms green LED yes 11-16 mA 3.6-4.5 mA 3.6 mA Output circuits Number of poles Rated voltage Rated current General data for CR-S with screw connection terminal 11-12/14 1 250 V AC 6A Dimensions without holder (L x W x H) Degree of protection (EN 60529) Temperature range 88.3 x 6.3 x 70.9 mm (3.476 x 0.248 x 2.789 in) Degree of protection (EN 60529) IP20 (terminals) operation -40...+70 °C storage 0...+40 °C Connection type Screw Maximum nuber of wires per connection terminal 2 CR-S 220-240 V 3.6 mA -40...+55 °C Wire size rigid 1 x 2.5 mm² (1 x 14 AWG) ; 2 x 1.5 mm² (2 x 16 AWG) fine-strand 1 x 2.5 mm² (1 x 14 AWG); 2 x 1.5 mm² (2 x 16 AWG) with wire end ferule 1 x 2.5 mm² (1 x 14 AWG); 2 x 1.0 mm² (2 x 18 AWG) Tightening torque 0.5 Nm (4.426 lb.in) Stripping length 7 mm (0.276 in) Mounting (IEC/EN 60715) DIN rail Material socket PA6 +GF-V2 contacts CuZn36 contact surface 3 μ Ni/Sn terminals CuZn40, 3 μ Ni combi screw M3 Fe General data for CR-S with spring connection terminal Dimensions without holder (L x W x H) 88.3 x 6.3 x 70.9 mm (3.476 x 0.248 x 2.789 in) Degree of protection (EN 60529) Degree of protection (EN 60529) IP20 (terminals) Temperature range operation -40...+70 °C -40...+55 °C storage 0...+40 °C Connection type Spring Maximum nuber of wires per connection terminal 1 Wire size 2.5 mm² (14 AWG) rigid, fine-strand and with wire end ferule Stripping length 7 mm (0.276 in) Mounting (IEC/EN 60715) DIN rail Material socket PA6 +GF-V2 contacts CuZn36 contact surface 3 μ Ni/Sn spring terminals SUS301 Isolation data Isolation between coil and contacts 5000 V AC Resistance to shock coil to contact 1000 MW Clearance and creepage distance IEC/EN 61984 Standards Product stancard IEC/EN 61984: 2001 Low Voltage Directive 2006/95/EC Endurance curve Operations (*1000 ops) 10 5 2 100 50 1 0.5 0.2 0.1 10 20 50 100 200 DC voltage (V) 5 0 1 2 3 4 5 6 7 8 Contact current (A) 2CDC 292 013 F0214 10 2CDC 292 012 F0214 DC current (A) Load limit curves - Max. DC load breaking capacity 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/22 5 Pluggable interface relays Load limit curves Load limit curves - Electrical lifetime at resistive AC load CR-P with 2 c/o contacts CR-M with 4 c/o contacts Switching power [kVA] 2CDC 292 022 F0204 Switching power [kVA] 2CDC 292 018 F0204 Switching cycles Switching cycles 2CDC 292 013 F0204 Switching power [kVA] Switching power [kVA] 2CDC 292 027 F0204 Switching cycles CR-M with 3 c/o contacts Switching cycles CR-M with 2 c/o contacts Switching power [kVA] 2CDC 292 009 F0204 2CDC 292 003 F0204 Switching power [kVA] 5 CR-U with 2 and 3 c/o contacts Switching cycles Switching cycles CR-P with 1 c/o contact Reduction factor F at inductive AC load CR-U 5/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Power factor 2CDC 292 029 F0204 Power factor 2CDC 292 014 F0204 Power factor 2CDC 292 004 F0204 Reduction factor Reduction factor CR-M Reduction factor CR-P Pluggable interface relays Connection diagrams 2CDC 292 016 F0004 2CDC 292 024 F0004 CR-P with 1 c/o contact 2CDC 292 011 F0004 2CDC 292 001 F0004 Connection diagrams CR-M with 2 c/o contacts CR-M with 3 c/o contacts CR-U with 2 c/o contacts CR-S 2CDC 292 030 F0004 CR-M with 4 c/o contacts CR-U with 3 c/o contacts 2CDC 292 025 F0004 Dimensions in mm and inches 2CDC 292 002 F0004 2CDC 292 001 F0015 Dimensional drawings 2CDC 292 001 F0014 CR-P with 2 c/o contacts 2CDC 292 020 F0004 2CDC 292 008 F0004 5 CR-U with 2 c/o contacts CR-M with 2 c/o contacts CR-P 0.5 0.020 1 0.039 16.38 0.645 5 0.197 3.78 0.149 5.04 0.198 2CDC 292 026 F0004 2CDC 292 002 F0015 0.9 0.035 3.5 0.138 0.5 0.020 2CDC 292 052 F0013 15 0.591 28 1.102 CR-U with 3 c/o contacts CR-M with 3 c/o contacts 2CDC 292 003 F0015 CR-S CR-M with 4 c/o contacts 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/24 Pluggable interface relays Dimensional drawings Dimensions in mm and inches 62 62 51,2 15,8 7,5 61 29 3.2 5.08 5.08 78.5 Relay 29.4 Pluggable function module 20.32 2CDC 292 006 F0211 Relay 76 20 10 42.5 Holder CR-PLS - screw connection Holder Pluggable function module 24 7.62 50 15.5 Marker 42.8 CR-PLSx - screw connection 43,5 33,8 7,62 76 20 10 Holder 24,4 97,5 25,9 9x15 (=139,5) 2CDC 292 010 F0011 5,08 CR-PSS - screw connection 20,32 15,8 5,08 Pluggable function module 24 2CDC 292 007 F0211 Relay 15,5 2±0,2 2CDC 292 012 F0011 ±0,2 R 1 1,5 10 10 6±0,2 141,5+1 16,3 34,4 CR-PLC - spring connection CR-PJ 76.6 3.016 70.9 2.791 6.2 0.244 55.4 2.181 35.7 1.406 92.7 3.650 73.2 2.882 Spring socket for CR-S range interface relays Screw socket for CR-S range interface relays Jumper 6.3 0.248 16.7 0.657 6.7 0.264 123.2 4.850 2CDC 292 002 F0014 0.8 0.031 2.8 0.110 Jumper bar CR-S 5/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Separator for CR-S 71.1 2.799 59.8 2.354 40.2 1.583 20.6 0.811 2CDC 292 054 F0013 52 2.047 88.3 3.476 69.4 2.732 35.4 1.394 28 1.102 44.2 1.74 2CDC 292 053 F0013 94.7 3.728 3.5 0.138 2CDC 292 003 F0014 6.3 0.272 35.8 1.409 35.4 1.394 5 2CDC 292 033 F0004 Marker Pluggable interface relays Dimensional drawings Dimensions in mm and inches 42,5 33,2 24 24 12,4 95 15 2CDC 292 003 F0211 Pluggable function module 27 Marker 26 42,6 27,2 27,2 27,2 79,5 24 CR-M2LC , CR-M4LC - spring connection Relay 29 max 2±0,2 27.2 ±0.2 CR-M2SS - CR-M3SS - CR-M4SS - screw connection 2CDC 292 005 F0011 66,7 Pluggable function module 19 35,4 2CDC 292 004 F0211 75,2 35,4 30,3 Holder 5 246.8 5,5 CR-M2LS - CR-M3LS - CR-M4LS - screw connection 9 x 27.2 (=244,8) 29,1 CR-M4LS 2CDC 292 006 F0005 CR-M3LS 35,4 75 CR-M2LS Holder 9,5 Relay R1 CR-MxSF - screw connection 2CDC 292 011 F0011 27,2 31 10 42,6 12,4 27,2 1 60,8 27,2 Marker 6±0,2 CR-MJ 37,3 38,1 4 29,8 29,8 CR-U2S CR-U3S CR-U2S - CR-U3S CR-U3E 38,1 38,1 11 - M3 2CDC 292 002 F0005 CR-U3SM 2CDC 292 009 F0011 35,4 61,8 61,8 8 - M3 CR-U2SM 26 27,8 27,8 CR-U2SM 2CDC 292 081 F0004 2CDC 292 008 F0011 9 - M3 35,4 75,3 75,3 12 - M3 4 CR-U3SM 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/26 Interface relays and optocouplers R600 range Product group picture 5 5/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Interface relays and optocouplers R600 range Table of contents Interface relays and optocouplers R600 range Benefits and advantages 5/29 Type designators 5/30 Interface relays R600 range. . ............................................................ 5/31 Benefits and advantages 5/31 Selection 5/33 Ordering details 5/35 Connection diagrams 5/37 Technical data 5/38 General technical data 5/43 Dimensional drawings, Load limit curves 5/44 Optocouplers R600 range................................................................ 5/45 Selection 5/45 Ordering details 5/47 Connection diagrams 5/48 Technical data 5/49 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/28 5 2CDC 291 024 F0013 Interface relays and optocouplers R600 range Benefits and advantages R600 series 5 Standard range in screw clamp or spring clamp versions –– Spacing : 6 mm or 12 mm –– Wire size : 2.5 mm² (4 mm² solid wire) –– Contact type : 1 NO, 1 NC, 1 SPDT, 1 DPDT from 1 mA to 8 A / 250 V In today’s automation systems, PLCs are the core of industry. They link sensors and actuators to the process, which are connected to the PLC via conventional wires. However these PLCs are not completely isolated from the industrial environment, hence over voltage picks and transient currents can affect their operating functions. And additionally, their application field is often limited to 24 VDC / 100 mA. So, with the aim to adapt application voltage and/or current and provide as well the right electrical isolation to the PLC, it is recommended to install per I/O the right interface providing both voltage-current level adaptation and isolation protection. This interfacing is possible thanks to ABB’s relays and optocouplers ranges, which offer wide adaptation in both voltage (from 5 to 400 V) and current (from 10-7 to 16 A) as well as high isolation between input and output from 2 to 4 KV. 5/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Interface relays and optocouplers R600 range Type designators SERIES R600 screw type R600 spring type CODE NB OF RELAYS CONTACT TYPE NB OF CONTACTS PER RELAY PARTICULARITIES R/B n n n n R/B/R n n n n 1 012 12 None / A / R Features None Input voltage A Input voltage Description of contact types 0 1 Normally Closed 1 NC 1 1 Normally Open 1 NO 2 1 Change Over or Single Pole Double Through DC AC/DC R RC circuit protection : - Input protection against leakage current - Increases relay contacts life 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/30 5 Interface relays R600 range Benefits and advantages 5 Characteristics –– Standard range available with screw or spring-type terminals –– 8 different rated control supply voltages: DC versions: 5 V, 12 V, 24 V AC/DC versions: 24 V, 48-60 V, 115 V, 230 V, 60-230 V –– Output: 1 n/c contact, 1 n/o contact, 1 c/o (SPDT) contact, 2 c/o (SPDT) contacts –– Devices with output contacts protected by built in RC circuit, which result in increased contact life –– Devices with leakage current protection on the input side –– Available with visible or covered switch on the front of the unit, for the configuration of manual or automatic actuation –– With connection for jumper bar, except 2 c/o devices and some discontinued devices –– Width: 6 mm (0.236 in) or 12 mm (0.472 in) –– LED for the indication of the operational state –– Accessories: Jumper bars, separator end section –– Approvals / Marks HR P (pending) / a 1 1 Input - Control supply voltage 2 Jumper bar connection 2 3 Indication of operational states (green LED) 4 Output 3 4 Excellent adaption and conversion of digital signals AC 110 V DC 24 V DC 24 V AC 110 V AC 230V AC 230 V Pushbutton R 600 Relay or Position Optocoupler PLC switch Sensor R 600 Relay or Optocoupler AC 380 V Motor contactor Motor 5/31 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Interface relays R600 range Benefits and advantages Interface relays are electromechanic and electronic input and output modules for electrical isolation, levelling, noise suppression or signal amplification between control unit and process. Boxed interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC (programmable logic controller), PC or field bus systems and the sensor / actuator level. The compact design and different connection terminal possibilities optimize your panel installation. 5 Variety of connections R600 relays and optocouplers are available with both screw terminals or spring terminals. Space safing With a width of only 6 mm or 12 mm the compact design safes space in each cabinet. Only one part number AC/DC 0.2 to 2.5 mm² 0.22 to 4 mm² 6 mm spacing 12 mm spacing Increased contact life The contacts of some devices are proteced by built in RC-circuits which result in increased contact life. Functioning status Functioning display through a green LED. Measurement & Test Holes for holding DIA. 2 mm test plugs to simplify any measurement or test. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/32 10 mA - 6 A c/o Screw Spring 1SNA645534R2500 1SNA645536R2700 1SNA645073R0000 1SNA645035R2400 1SNA645075R0000 1SNA645575R0000 1SNA645535R2600 1SNA645573R0000 1SNA645019R0400 1SNA645519R0600 1SNA645014R2700 1SNA645018R0300 1SNA645514R2100 1SNA645001R0300 1SNA645005R0700 1SNA645501R0500 1SNA645505R0100 1SNA645012R2500 1SNA645512R2700 1SNA645071R0000 1SNA645571R0000 1SNA645072R0000 1SNA645572R0000 1SNA645002R0400 1SNA645006R0000 1SNA645502R0600 1SNA645506R0200 1SNA645040R1500 RBR 121-5VDC RBR 121-5VDC RB121-12VDC RB121-12VDC RB121-AU-12VDC RBR121-AU-12VDC RBR121-12VDC RBR121-12VDC RB 101AR-24VAC/DC RBR 101AR-24VAC/DC RB 111A-24VAC/DC RB 111AR-24VAC/DC RBR 111A-24VAC/DC RB 121A-24VAC/DC RB 121A-24VAC/DC RBR 121A-24VAC/DC RBR 121A-24VAC/DC RB 122A-24VAC/DC RBR 122A-24VAC/DC RB121-24VDC RBR121-24VDC RB121-AU-24VDC 1SNA645572R0000 RB 121A-48-60VAC/DC RB 121A-48-60VAC/DC RBR 121A-48-60VAC/DC RBR 121A-48-60VAC/DC RB 122A-48-60VAC/DC RBR 122A-48-60VAC/DC 1SNA645540R1700 48-60 V DC 1SNA645036R2500 24 V DC RB 121-5VDC 12 V DC 1SNA645034R2300 5 V DC RB 121-5VDC Input voltage Order number 5 Type Interface relays R600 range Selection J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J 115 V DC 230 V DC 60-230 V DC 24 V AC J J 1 mA - 6 A 1 J J J 1 1 J J 1 1 J J J J J 1 J J J 1 1 J 1 J J J n/c 1 J J J J n/o J J J J J Terminal type 1 1 1 J J J 5/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 J J 1 J J J J J 1 1 1 J J J J 1 J J 1 mA - 8 A 1 J J J 48-60 V AC 115 V AC 230 V AC 60-230 V AC Output rating J J Output contacts J J 2 2 1 J J J J 1 J J J J 1 J 1 J J J J J J J J J J 2 2 J J 1 1 J J J 1 J 1 J J J 1SNA645003R0500 1SNA645007R0100 1SNA645046R0700 1SNA645503R0700 1SNA645507R0300 1SNA645546R0100 1SNA645041R0200 1SNA645541R0400 1SNA645016R2100 1SNA645017R2200 1SNA645004R0400 1SNA645008R1200 1SNA645011R2400 1SNA645504R0000 1SNA645508R1400 1SNA645511R2600 1SNA645013R2600 1SNA645513R2000 1SNA645020R0100 1SNA645520R0300 RB 121A-115VAC/DC RB 121A-115VAC/DC RB 121AR-115VAC/DC RBR 121A-115VAC/DC RBR 121A-115VAC/DC RBR 121AR-115VAC/DC RB 122A-115VAC/DC RBR 122A-115VAC/DC RB 111A-115VAC/DC RB 111A-230VAC/DC RB 121A-230VAC/DC RB 121A-230VAC/DC RB 121AR-230VAC/DC RBR 121A-230VAC/DC RBR 121A-230VAC/DC RBR 121AR-230VAC/DC RB 122A-230VAC/DC RBR 122A-230VAC/DC RB 121A 60-230VUC RBR 121A 60-230VUC Interface relays R600 range Selection J J J J J J J J J J J J J J J J J J J J J 1 J J J 1 J J J 1 J J 1 J J J 1 J J 1 J J J J J J J 2 2 J J J J J J 1 1 J J J J J J J J 1 1 1 J J J J J 1 J J J 1 J J 1 J J J J J J J 2 2 J J J J J J 1 1 J J 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/34 5 Interface relays R600 range Ordering details Ordering details - 1 n/c contact: 250 V, 10 mA - 6 A (high level), width 12 mm Rated control Particularities and supply voltage connection type 24 V AC/DC RC circuit parallel to contact on output side Type Order code RB101AR-24VAC/DC 1SNA645019R0400 RBR101AR-24VAC/DC 1SNA645519R0600 Price Pkg qty Weight (1 pce) kg (lb) 5 0.04 (0.088) Pkg qty Weight (1 pce) kg (lb) 10 0.02 (0.044) Pkg qty Weight (1 pce) kg (lb) 5 0.04 (0.088) 2CDC 291 024 S0013 Ordering details - 1 n/o contact: 250 V, 10 mA - 6 A (high level) width 6 mm 5 R600 - 6 mm Rated control Particularities and supply voltage connection type Type Order code 24 V AC/DC RB111A-24VAC/DC 1SNA645014R2700 115 V AC/DC RB111A-115VAC/DC 1SNA645016R2100 230 V AC/DC RB111A-230VAC/DC 1SNA645017R2200 24 V AC/DC RBR111A-24VAC/DC 1SNA645514R2100 Price screw terminals Ordering details - 1 n/o contact: 250 V, 10 mA - 6 A (high level), width 12 mm spring terminals Rated control Particularities and supply voltage connection type 24 V AC/DC RC circuit parallel to contact on output side Type Order code RB111AR-24VAC/DC 1SNA645018R0300 RBR111AR-24VAC/DC 1SNA645518R0500 Price Ordering details - 1 c/o (SPDT) contact: 250 V, 1 mA - 6 A (low level), width 6 mm Rated control Particularities and supply voltage connection type 5 V DC A1-A2 polarized Type Order code RB121-5VDC 1SNA645036R2500 12 V DC RB121-AU-12VDC 1SNA645075R0000 24 V DC RB121-AU-24VDC 1SNA645072R0000 24 V AC/DC RB121A-24VAC/DC 1SNA645005R0700 48-60 V AC/DC RB121A-48-60VAC/DC 1SNA645006R0000 115 V AC/DC RB121A-115VAC/DC 1SNA645007R0100 RB121A-230VAC/DC 1SNA645008R1200 RBR121-5VDC 1SNA645536R2700 12 V DC RBR121-AU-12VDC 1SNA645575R0000 24 V DC RBR121-AU-24VDC 1SNA645572R0000 24 V AC/DC RBR121A-24VAC/DC 1SNA645505R0100 48-60 V AC/DC RBR121A-48-60VUC 1SNA645506R0200 115 V AC/DC RBR121A-115VAC/DC 1SNA645507R0300 230 V AC/DC RBR121A-230VAC/DC 1SNA645508R1400 230 V AC/DC 5 V DC A1-A2 polarized 5/35 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Price Pkg qty Weight (1 pce) kg (lb) 10 0.02 (0.044) Interface relays R600 range Ordering details 2CDC 291 013 S0013 Ordering details - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A (high level), width 6 mm R600 - 12 mm screw terminals Rated control Particularities and supply connection type voltage Type Order code 5 V DC A1-A2 polarized RB121-5VDC 1SNA645034R2300 12 V DC A1-A2 polarized RB121-12VDC 1SNA645035R2400 12 V DC RB121-12VDC 1SNA645073R0000 24 V DC RB121-24VDC 1SNA645071R0000 24 V AC/DC RB121A-24VAC/DC 1SNA645001R0300 48-60 V AC/DC RB121A-48-60VAC/DC 1SNA645002R0400 115 V AC/DC RB121A-115VAC/DC 1SNA645003R0500 230 V AC/DC RB121A-230VAC/DC 1SNA645004R0400 5 V DC A1-A2 polarized RBR121-5VDC 1SNA645534R2500 12 V DC A1-A2 polarized RBR121-12VDC 1SNA645535R2600 12 V DC RBR121-12VDC 1SNA645573R0000 24 V DC RBR121-24VDC 1SNA645571R0000 24 V AC/DC RBR121A-24VAC/DC 1SNA645501R0500 48-60 V AC/DC RBR121A-48-60VUC 1SNA645502R0600 115 V AC/DC RBR121A-115VAC/DC 1SNA645503R0700 230 V AC/DC RBR121A-230VAC/DC 1SNA645504R0000 Price Pkg qty Weight (1 pce) kg (lb) 10 0.02 (0.044) 5 spring terminals Ordering details - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A (high level), width 12 mm Rated control Particularities and supply voltage connection type Type Order code 60-230 V AC/DC RB121A-60-230VUC 1SNA645020R0100 115 V AC/DC RB121AR-115VAC/DC 1SNA645046R0700 RB121AR-230VAC/DC 1SNA645011R2400 RBR121A-60-230VUC 1SNA645520R0300 RBR121AR-115VAC/DC 1SNA645546R0100 RBR121AR-230VAC/DC 1SNA645511R2600 230 V AC/DC Leakage current protection, input side 60-230 V AC/DC 115 V AC/DC 230 V AC/DC Leakage current protection, input side Price Pkg qty Weight (1 pce) kg (lb) 0.04 (0.088) Ordering details - 2 c/o (SPDT) contacts: 250 V, 1 mA - 8 A (low level), width 12 mm Rated control supply voltage Connection type Type Order code 24 V AC/DC RB122A-24VAC/DC 1SNA645012R2500 48-60 V AC/DC RB122A-48-60VAC/DC 1SNA645040R1500 115 V AC/DC RB122A-115VAC/DC 1SNA645041R0200 230 V AC/DC RB122A-230VAC/DC 1SNA645013R2600 24 V AC/DC RBR122A-24VAC/DC 1SNA645512R2700 48-60 V AC/DC RBR122A-48-60VUC 1SNA645540R1700 115 V AC/DC RBR122A-115VAC/DC 1SNA645541R0400 230 V AC/DC RBR122A-230VAC/DC 1SNA645513R2000 Type Order code 24 V AC/DC BJ 612-10 1SNA290488R0100 48-60 V AC/DC BJ 612-20 1SNA206754R0000 230 V AC/DC SC 612 1SNA290474R0200 Price Pkg qty Weight (1 pce) kg (lb) 5 0.04 (0.088) Pkg qty Weight (1 pce) kg (lb) 0.05 (0.11) 0.01 (0.022) 0.05 (0.11) Ordering details - Accessories Description BJ... SC612 Price 10 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/36 Interface relays R600 range Connection diagrams Control supply voltage Connection for jumper bar (input side) Connection for jumper bar (output side) A1 RB/RBR 101 AR A2 S1 S2 RB/RBR 111 A - 24 V AC/DC 5 13 11 S2 RB/RBR 121 - 5 V DC, A1-A2 polarized - 12 V DC, A1-A2 polarized, i.e. only: 1SNA645035R2400, 1SNA645535R2600 RB/RBR 121 A - 24 V AC/DC A2 S1 11 S2 2CDC 292 043 F0013 A1 21 A2 S1 11 RB/RBR 122 A - 115/230 V AC/DC 5/37 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 21 A2 S1 RB/RBR 121 AR 12 14 22 24 12 14 22 24 A1 11 A1 RB/RBR 121 A - 48/60/115/230 V AC/DC RB/RB 122 A - 24/48/60 V AC/DC S2 12 14 2CDC 292 040 F0013 2CDC 292 039 F0013 11 11 S1 RB/RBR 121 (AU) - 12/24 V DC, except: 1SNA645035R2400, 1SNA645535R2600 see connection diagram RB...121-5VDC A1 S2 A2 12 14 12 14 A1 A2 S1 12 14 A2 S1 14 A1 2CDC 292 036 F0013 14 RB/RBR 111 AR A2 S1 S2 12 14 2CDC 292 035 F0013 S2 A2 S1 RB/RBR 111 A - 48/60/115/230 V AC/DC A1 A1 A2 S1 14 2CDC 292 033 F0013 11 A1 2CDC 292 031 F0013 S2 2CDC 292 030 F0013 A2 S1 13 13 12 A1 2CDC 292 038 F0013 A1-A2 S1 S2 S2 11 2CDC 292 042 F0013 n/c contact n/o contact 1st c/o contact 2nd c/o contact 2CDC 292 044 F0013 11-12 13-14 11-12/14 21-22/24 Interface relays R600 range Technical data Technical data RB... 111A high level Input circuit Rated control supply voltage U s Rated control supply voltage U s tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states 24 V AC/DC 48 V AC/DC 60 V AC/DC DC -15 %, +20 % AC -/+ 10 % 50/60 Hz 0.24 W 0.34 W 0.54 W 10 mA 7 mA 9 mA 4.5 V 8V 8V green LED V : control supply voltage applied 115 V AC/DC 230 V AC/DC -15 %, +10 % 0.46 W 4 mA 17 V 0.8 W 3.5 mA 27 V Output circuit Kind of output 13-14 relay, 1 n/o contact Rated operational voltage U e (IEC/EN 60947-1) 250 V AC Minimum switching voltage Maximum switching voltage Minimum switching current Rated free air thermal current I th 12 V 250 V AC 10 mA 6A Rated operational current (IEC/EN 60947-5-1) 6A 1.5 A 3A 6A 1A 0.2 A 0.1 A B300 AC-12 (resistive) 230 V AC-15 (inductive) 230 V AC-15 (inductive) 120 V DC-12 (resistive) 24 V DC-13 (inductive) 24 V DC-13 (inductive) 120 V DC-13 (inductive) 230 V Utilization category (pilot duty) AC rating (UL 508; NEMA ICS-5) DC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) Minimum switching power Mechanical lifetime Electrical lifetime at AC-15 Response time Release time Dimensions and weight Weight net weight Dimension 5 R300 0.6 W / 0.6 VA 1 x 107 switching cycles 1 x 10 5 switching cycles 5 ms 5 ms 8 ms 8 ms RB 111 A 0.02 kg (0.044 lb) product dimension 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in) 5 ms 8 ms 6 ms 15 ms 7 ms 15 ms RBR 111 A 6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/38 Interface relays R600 range Technical data Technical data RB... 111AR high level Input circuit Rated control supply voltage U s Rated control supply voltage U s tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states 24 V AC/DC DC -15 %, +20 % AC -/+ 10 % 50/60 Hz 0.24 W 10 mA 4.5 V green LED V : control supply voltage applied Output circuit Kind of output 11-12 13-14 relay, 1 n/o contact Rated operational voltage U e (IEC/EN 60947-1) 250 V AC 5 RB... 101AR high level Minimum switching voltage Maximum switching voltage Minimum switching current Rated free air thermal current I th 12 V 250 V AC 10 mA 6A Rated operational current (IEC/EN 60947-5-1) 6A 1.5 A 3A 6A 1A 0.2 A 0.1 A B300 AC-12 (resistive) 230 V AC-15 (inductive) 230 V AC-15 (inductive) 120 V DC-12 (resistive) 24 V DC-13 (inductive) 24 V DC-13 (inductive) 120 V DC-13 (inductive) 230 V Utilization category (pilot duty) AC rating (UL 508; NEMA ICS-5) DC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) Minimum switching power Mechanical lifetime Electrical lifetime at AC-15 Response time Release time Dimensions and weight Weight net weight Dimension product dimension relay, 1 n/c contact - R300 0.6 W / 0.6 VA 1 x 107 switching cycles 1 x 10 5 switching cycles 5 ms 8 ms RB 111AR / RB 101AR high level 0.03 kg (0.066 lb) 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in) 5/39 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 RBR 111A / RBR 111AR high level 12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in) Interface relays R600 range Technical data Technical data RB... 121 / RB... 121A high level Input circuit Rated control supply voltage U s Rated control supply voltage U s tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states 5 V DC 12 V DC 24 V AC/DC DC -15 %, +20 % AC -/+ 10 % 50/60 Hz 0.2 W 0.2 W 0.24 W 40 mA 16 mA 10 mA 1.2 V 2.2 V 4.5 V green LED V : control supply voltage applied 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC -15 %, +10 % 0.33 W 7 mA 8V 0.54 W 9 mA 8V 0.46 W 4 mA 17 V 0.8 W 3.5 mA 27 V Output circuit Kind of output 11-12/14 relay, 1 c/o (SPDT) contact Rated operational voltage U e (IEC/EN 60947-1) 250 V AC Minimum switching voltage Maximum switching voltage Minimum switching current Rated free air thermal current I th 12 V 250 V AC 10 mA 6A Rated operational current (IEC/EN 60947-5-1) 6A 1.5 A 3A 6A 1A 0.2 A 0.1 A B300 AC-12 (resistive) 230 V AC-15 (inductive) 230 V AC-15 (inductive) 120 V DC-12 (resistive) 24 V DC-13 (inductive) 24 V DC-13 (inductive) 120 V DC-13 (inductive) 230 V Utilization category (pilot duty) AC rating (UL 508; NEMA ICS-5) DC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) Minimum switching power Mechanical lifetime Electrical lifetime at AC-15 Response time Release time Dimensions and weight Weight net weight Dimension product dimension 5 R300 0.6 W / 0.6 VA 1 x 107 switching cycles 1 x 10 5 switching cycles 5 ms 5 ms 5 ms 8 ms 8 ms 8 ms RB 121 / RB 121A high level 0.02 kg (0.044 lb) 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in) 5 ms 8 ms 5 ms 6 ms 7 ms 8 ms 15 ms 16 ms RBR 121 / RBR 121 A high level 6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/40 Interface relays R600 range Technical data Technical data RB... 121 / RB... 121A low level Input circuit Rated control supply voltage U s Rated control supply voltage U s tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states 5 V DC 12 V DC 24 V AC/DC DC -15 %, +20 % AC -/+ 10 % 50/60 Hz 0.2 W 0.2 W 0.24 W 40 mA 16 mA 10 mA 1.2 V 2.2 V 4.5 V green LED V : control supply voltage applied 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC -15 %, +10 % 0.33 W 7 mA 8V 0.54 W 9 mA 8V 0.46 W 4 mA 17 V 0.8 W 3.5 mA 27 V Output circuit Kind of output 11-12/14 relay, 1 c/o (SPDT) contact Rated operational voltage U e (IEC/EN 60947-1) 250 V AC 5 Minimum switching voltage Maximum switching voltage Minimum switching current Rated free air thermal current I th 5V 250 V AC 1 mA 6A Rated operational current (IEC/EN 60947-5-1) 6A 1.5 A 3A 6A 1A 0.2 A 0.1 A B300 AC-12 (resistive) 230 V AC-15 (inductive) 230 V AC-15 (inductive) 120 V DC-12 (resistive) 24 V DC-13 (inductive) 24 V DC-13 (inductive) 120 V DC-13 (inductive) 230 V Utilization category (pilot duty) AC rating (UL 508; NEMA ICS-5) DC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) Minimum switching power Mechanical lifetime Electrical lifetime at AC-15 Response time Release time Dimensions and weight Weight net weight Dimension product dimension R300 0.05 W / 0.05 VA 1 x 107 switching cycles 1 x 10 5 switching cycles 5 ms 5 ms 5 ms 8 ms 8 ms 8 ms RB 121 / RB 121A low level 0.02 kg (0.044 lb) 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in) 5/41 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 5 ms 8 ms 5 ms 6 ms 7 ms 8 ms 15 ms 16 ms RBR 121 / RBR 121 A low level 6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in) Interface relays R600 range Technical data Technical data RB... 121AR Input circuit Rated control supply voltage U s Rated control supply voltage U s tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states 115 V AC/DC 230 V AC/DC DC -20%, +15% -10%, +15% AC -/+ 10 % 50/60 Hz 2W 2.8 W 18 mA 12 mA 17 V 27 V green LED V : control supply voltage applied Output circuit Kind of output 11-12/14 relay, 1 c/o (SPDT) contact Rated operational voltage U e (IEC/EN 60947-1) 250 V AC Minimum switching voltage Maximum switching voltage Minimum switching current Rated free air thermal current I th 12 V 250 V AC 10 mA 6A Rated operational current (IEC/EN 60947-5-1) 6A 1.5 A 3A 6A 1A 0.2 A 0.1 A B300 AC-12 (resistive) 230 V AC-15 (inductive) 230 V AC-15 (inductive) 120 V DC-12 (resistive) 24 V DC-13 (inductive) 24 V DC-13 (inductive) 120 V DC-13 (inductive) 230 V Utilization category (pilot duty) AC rating (UL 508; NEMA ICS-5) DC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) Minimum switching power Mechanical lifetime Electrical lifetime at AC-15 Response time Release time Dimensions and weight Weight net weight Dimension product dimension 5 R300 0.6 W / 0.6 VA 1 x 107 switching cycles 1 x 10 5 switching cycles 6 ms 15 ms 7 ms 16 ms RB 121AR RBR 121AR 0.03 kg (0.066 lb) 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in) 12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in) Technical data RB... 122A low level Input circuit Rated control supply voltage U s Rated control supply voltage U s tolerance Rated frequency Typical power consumption Typical current Drop-out Indication of operational states 24 V AC/DC 48 V AC/DC 60 V AC/DC DC -15 %, +20 % AC -/+ 10 % 50/60 Hz 0.48 W 0.62 W 0.96 W 20 mA 13 mA 16 mA 5.4 V 8.8 V 8.8 V V green LED V : control supply voltage applied 115 V AC/DC 230 V AC/DC -15 %, +10 % 0.58 W 5 mA 20 V 1.15 W 5 mA 10 V Output circuit Kind of output 11-12/14 relay, 1st c/o (SPDT) contact 21-22/24 relay, 2nd c/o (SPDT) contact Rated operational voltage U e (IEC/EN 60947-1) 250 V AC Minimum switching voltage Maximum switching voltage Minimum switching current Rated free air thermal current I th 5V 250 V DC - 250 V AC 1 mA 8A 5A Rated operational AC-12 (resistive) 230 V current DC-12 (resistive) 24 V (IEC/EN 60947-5-1) Minimum switching power Mechanical lifetime Electrical lifetime at AC-15 Response time Release time Dimensions and weight Weight net weight Dimension product dimension 8A 5A 8A 5A 5 mW / 5 mVA 2 x 107 switching cycles 1 x 10 5 switching cycles 6 ms 10 ms 10 ms 10 ms 14 ms 14 ms RB 122A low level 0.03 kg (0.066 lb) 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in) 6 ms 6 ms 15 ms 15 ms RBR 122A low level 12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/42 Interface relays R600 range General technical data Technical data General data Material of housing Electrical connection Wire size Stripping length Tightening torque Environmental data Ambient temperature ranges 5 RBR Screw terminal Spring-type terminal UL 94 V0 Mounting Degree of protection RB DIN Rail housing / IP20 NEMA1 terminals fine-stranded 0.22-2.5 mm² (24-14 AWG) rigid 0.2-4 mm² (24-12 AWG) 9 mm / 0.354 in 0.4-0.6 Nm (3.5-5.3 lb.in) 0.2-2.5 mm² (24-14 AWG) storage -40...+80 °C operation -20...+70 °C Isolation data Rated insulation voltage U i (IEC/EN 60950-1, EN 50178) Rated impulse withstand input / output voltage U imp (EN 50178) shock coil / output output / output 4000 V RMS 4000 V RMS (RB122A: 3800 V RMS, RB111AR: 3500 V RMS) 4000 V RMS 1000 V RMS 5/43 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Interface relays R600 range Dimensional drawings, Load limit curves All interface relays of R600 range center of rail center of rail Spring clamp module Screw clamp module 5 Load limit curves Limited load in CC Voltage [V] Voltage (Vcc) Max. DC load breaking capacity resistive load Current (Acc) Current [A] Versions with 1 n/o, 1 n/c or 1 c/o contact 24 V 110/120 V 220/230 V DC-12 6A 0,3 A 0.2 A AC-12 6A 6A 6A DC-13 1 0.2 A 0.1 A Versions with 2 c/o contacts AC-15 3A 3A 3A 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/44 100 mA 58 V DC Screw Spring J J 1SNA645021R2600 1SNA645521R2000 1SNA645049R1200 1SNA645549R1400 1SNA645022R2700 1SNA645522R2100 1SNA645050R1700 1SNA645550R1100 1SNA645051R0400 1SNA645025R2200 1SNA645024R2100 1SNA645551R0600 1SNA645525R2400 1SNA645524R2300 1SNA645053R0600 1SNA645553R0000 1SNA645054R0700 1SNA645058R1300 1SNA645554R0100 1SNA645558R1500 1SNA645026R2300 1SNA645059R1400 1SNA645526R2500 1SNA645559R1600 1SNA645027R2400 1SNA645029R0600 1SNA645527R2600 1SNA645529R0000 OBRIC 0100 24VDC OBIC 0100 48-60VAC/DC OBRIC 0100 48-60VAC/DC OBIC 0100 115-230VAC/DC OBRIC 0100 115-230VAC/DC OBOC 1000-5-12VDC OBROC 1000-5-12VDC OBOC 1000-24VDC OBOC 1500-24VAC/DC OBOC 5000-24VDC OBROC 1000-24VDC OBROC 1500-24VAC/DC OBROC 5000-24VDC OBOC 1000-48-60VAC/DC OBROC 1000-48-60VAC/DC OBOC 1000-115VAC/DC OBOC 5000-115VAC/DC OBROC 1000-115VAC/DC OBROC 5000-115VAC/DC OBOC 1000-230VAC/DC OBOC 5000-230VAC/DC OBROC 1000-230VAC/DC OBROC 5000-230VAC/DC OBOA 1000-24VDC OBOA 2000-24VDC OBROA 1000-24VDC OBROA 2000-24VDC J 1SNA645547R0200 J OBIC 0100 24VDC 24 V DC OBRIC 0100 5-12VDC 1SNA645047R0000 5-12 V DC Order number Input voltage OBIC 0100 5-12VDC 5 Type Optocouplers R600 range Selection J J J J J J J J J J J J J J 48-60 V DC 115-230 V DC J 48-60 V AC J J J J J J J J J J J J J J 115 V DC 230 V DC J 115-230 V AC J J J J J J J J J 24 V AC J J J J J 2A 5A J J J J J J J J J J J J J 5/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 J J J J J J J J J J J J J J J J J 115 V AC J J J J J J J J J J J J J J J J J J J J J J 230 V AC J J J J J J J J J J J J Output rating J J J J J J J J J J J J 1A J 230 V AC 400 V AC J J J J J Output voltage J J J J J Terminal type J J J 1SNA645061R0600 1SNA645561R0000 1SNA645062R0700 1SNA645562R0100 1SNA645028R0500 1SNA645528R0700 OBOA 1000-48-60VAC/DC OBROA 1000-48-60VAC/DC OBOA 1000-115VAC/DC OBROA 1000-115VAC/DC OBOA 1000-230VAC/DC OBROA 1000-230VAC/DC Optocouplers R600 range Selection J J J J J J J J J J J J J J J J J J J J J J J J J J 5 J J J J 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/46 Optocouplers R600 range Ordering details Ordering details - R600 range R600 Optocoupler 2CDC 291 001 F0013 Optocoupler module 100 mA/DC Optocoupler module 100 mA/DC 5 Optocoupler module 2 A/DC screw terminals spring terminals Optocoupler module 2 A/DC Optocoupler module 5 A/DC Optocoupler module 5 A/DC Optocoupler module 1 A/AC 6 mm spacing Optocoupler module 2 A/AC 12 mm spacing Optocoupler module 1 A/AC 6 mm spacing Optocoupler module 2 A/AC 12 mm spacing Accessories BADH BADL D 4/12-3... SC612 FC2 Order code OBIC 0100-5-12VDC 1SNA645047R0000 OBIC 0100-24VDC 1SNA645021R2600 OBIC 0100-48-60VAC/DC 1SNA645049R1200 OBIC 0100-115-230VAC/DC 1SNA645022R2700 OBRIC 0100-5-12VDC 1SNA645547R0200 OBRIC 0100-24VDC 1SNA645521R2000 OBRIC 0100-48-60VAC/DC 1SNA645549R1400 OBRIC 0100-115-230VAC/DC 1SNA645522R2100 OBOC 1000-5-12VDC 1SNA645050R1700 OBOC 1000-24VDC 1SNA645051R0400 OBOC 1500-24VAC/DC 1SNA645025R2200 OBOC 1000-48-60VAC/DC 1SNA645053R0600 OBOC 1000-115VAC/DC 1SNA645054R0700 OBOC 1000-230VAC/DC 1SNA645026R2300 OBROC 1000-5-12VDC 1SNA645550R1100 OBROC 1000-24VDC 1SNA645551R0600 OBROC 1500-24VAC/DC 1SNA645525R2400 Price OBROC 1000-48-60VAC/DC 1SNA645553R0000 OBROC 1000-115VAC/DC 1SNA645554R0100 OBROC 1000-230VAC/DC OBOC 5000-24VDC OBOC 5000-115VAC/DC 1SNA645526R2500 1SNA645024R2100 1SNA645058R1300 OBOC 5000-230VAC/DC 1SNA645059R1400 OBROC 5000-24VDC 1SNA645524R2300 OBROC 5000-115VAC/DC 1SNA645558R1500 OBROC 5000-230VAC/DC 1SNA645559R1600 OBOA 1000-24VDC 1SNA645027R2400 OBOA 1000-48-60VAC/DC 1SNA645061R0600 OBOA 1000-115VAC/DC 1SNA645062R0700 OBOA 1000-230VAC/DC 1SNA645028R0500 OBOA 2000-24VDC 1SNA645029R0600 OBROA 1000-24VDC 1SNA645527R2600 OBROA 1000-48-60VAC/DC 1SNA645561R0000 OBROA 1000-115VAC/DC 1SNA645562R0100 OBROA 1000-230VAC/DC 1SNA645528R0700 OBROA 2000-24VDC 1SNA645529R0000 Weight (1 pce) kg (lb) 10 0.02 (0.44) 10 0.02 (0.44) 10 0.02 (0.44) 10 0.02 (0.44) 10 0.02 (0.44) 10 0.02 (0.44) 10 0.03 (0.066) 5 0.03 (0.066) 10 0.03 (0.066) 5 0.03 (0.066) Pkg qty Weight (1 pce) kg (lb) Order code BADH V0 1SNA116900R2700 50 BADL V0 1SNA399903R0200 50 BAM2 V0 1SNA399967R0100 50 Seperator end section SC 612 1SNA290474R0200 10 Divisible shunt 10 poles BJ 612-10 1SNA290488R0100 10 Divisible shunt 20 poles BJ 612-20 1SNA206754R0000 10 Test plug DIA. 2 mm FC2 1SNA645531R2200 10 Marking method RC65 / RC610 see marking 5/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Price Pkg qty Type End section BJ... Type Optocouplers R600 range Connection diagrams OB...IC 0100 - 5-12 V DC 115-230 V AC/DC OB...IC 0100 24 V DC 24-48-60 V AC/DC OB...OC 1000 - 5-12 V DC 5 OB...OC 1500 - 24 V AC/DC OB...OC 1000 24 V DC 48-60-115-230 V AC/DC OB...OC 5000 24 V DC 24-48-60-115-230 V AC/DC OB...OA 1000 24 V DC 48-60-115-230 V AC/DC OB...OA 2000 - 24 V DC 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/48 Optocouplers R600 range Technical data Optocoupler : 5 to 58 V DC output / 100 mA - 6 mm 0.236“ spacing OB...IC 0100 Relay characteristics coil Input voltage: +20%, -15% on DC ; 10%, -10% on AC 5 V DC - 12 V DC 24 V DC Frequency Input current AC/DC 5 mA Pull-in voltage at Is=100% 4V Switching time C / O 10 µs / 500 µs Operating frequency 1000 Hz 9 mA 7 mA / 16 mA 5 mA 11.5 mA / 25 mA 4 mA 4 mA 15 V 25 V 60 V AC / 70 V DC 5 ms / 20 ms 5 ms / 15 ms 20 Hz Output 0.9 mA Output voltage 4.5 to 58 V DC Output current min. 1 mA Output current max. 100 mA Output leakage current at U max. Residual voltage at I max and U rated 230 V AC/DC 50 / 60 Hz Permissible leakage current 5 48 V AC/DC 60 V AC/DC 115 V AC/DC 1 mA 0.9 mA 1.6 mA < 50 µA typical 1 V max 1.3 V Frequency on inductive load Isolation Input / Output Temperature input / 2500 V RMS Output storage -40...+80 °C operating -20...+70 °C 1) Screw clamp Other characteristics Body material Wire size Rated wire size Spring clamp grey UL 94 V0 Solid wire 0.2 - 4 mm ² (24-12 AWG) Stranded 0.22 - 2.5 mm² (24-12 AWG) wire 2.5 mm ² (12 AWG) 0.2-2.5 mm² (24-12 AWG) Wire stripping length 9 mm (0.354 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending for 12 V DC) , (pending), , LRS , CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Reference standards 1) Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased. Dimensional drawings center of rail center of rail Screw clamp module Spring clamp module 5/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Optocouplers R600 range Technical data Optocoupler : 5 to 58 V DC output / 2 A - 6 mm 0.236“ spacing OB..OC OB...OC 0100 OB...OC 1000 1500 Relay characteristics coil Input voltage: +20%, -15% on DC ; 10%, -10% 5 V DC - 12 V DC on AC 24 V DC Frequency 24 V AC/ DC 48 V AC/ DC 60 V AC/ DC 115 V AC/ DC 230 V AC/ DC 5.1 mA 4.2 mA 4 mA 50 / 60 Hz Input current 5 mA Pull-in voltage at Is=100% 9 mA 4 mA 6.3 mA 4 mA 4V 15 V 15 V 27 V 50 V 80 V Switching time C / O 15 µs / 250 µs 30 µs / 400 µs 1 ms / 7 ms 5 ms / 20 ms 500 µs / 10 ms 1 ms / 15 ms Operating frequency 2000 Hz 1000 Hz 60 Hz 20 Hz Permissible leakage current 1 mA 0.8 mA 0.9 mA 1 mA 0.3 mA Output Output voltage 4.5 to 58 V DC Output current min. 1 mA Output current max. 2A Output leakage current at U max. Residual voltage at I max and U rated 5 < 50 µA typical 0.1 V max 0.5 V Frequency on inductive load Isolation Input / Output Temperature input / Output 2500 V RMS storage -40...+80 °C operating -20...+70 °C 1) Screw clamp Other characteristics Body material Wire size Spring clamp grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) 0.2-2.5 mm² (24-12 AWG) Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 9 mm (0.354 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending for 12 V DC) , (pending), , LRS , CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Reference standards 1) Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased. Dimensional drawings center of rail center of rail Screw clamp module Spring clamp module 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/50 Optocouplers R600 range Technical data Optocoupler : 5 to 58 V DC output / 5 A - 6 mm 0.236“ spacing OB... OC 5000 Input Input voltage 24 V DC Frequency 115 V AC/DC 230 V AC/DC 50 / 60 Hz 50 / 60 Hz Input current 5.4 mA 4.2 mA 4 mA Pull-in voltage at Is=100% 12 V 50 V 80 V Switching time C / O 30 µs / 400 µs 500 µs / 10 ms 1ms / 15 ms Operating frequency 1000 Hz 50 Hz 35 Hz Permissible leakage current 0.8 mA 0.3 mA 0.3 mA Output 5 Output voltage 4.5- 58 V DC Output current min. Output current max. 1 mA 5A Output leakage current at U max. Residual voltage at I max and U rated < 50 µA typical 0.1 V max 0.5 V Frequency on inductive load Isolation Input / Output See Note 1 input / Output 2500 V RMS Temperature Ambient temperature storage -40...+80 °C operating See derating curve Other characteristics Body material Wire size grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 10 mm (0.394 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending), CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Reference standards Dimensional drawings center of rail Screw clamp module center of rail Spring clamp module 5/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Optocouplers R600 range Technical data Optocoupler : 24 to 400 V AC output / 1 A or 2 A max. - 6 mm or 12 mm spacing OB...OA OB...OA 1000 2000 Relay characteristics coil Input voltage: +20%, -15% on DC ; 10%, -10% on AC 24 V DC 48 V AC/DC Frequency 60 V AC/DC 115 V AC/DC 230 V AC/DC 24 V DC 50/60 Hz Input current 3.6 mA 4.3 mA 5.5 mA 4.15 mA 4.6 mA 3.6 mA Pull-in voltage at Is=100% 14 V 15 V 18 V 60 V 135 V 14 V Switching time C / O 150 µs / 1 ms 3 ms / 30 ms 2.2 ms / 18 ms 2.5 ms / 25 ms 150 µs / 1 ms Operating frequency 500 Hz 20 Hz 25 Hz 20 Hz 500 Hz Permissible leakage current 1 mA Output Output voltage 24-400 V AC Frequency 50/60 Hz Output current min. 25 mA Output current max. 1A Output leakage current at U max. < 0.50 mA Residual voltage at I max and U rated 10-230 V AC 2A typical 1 V max 1.6 V Frequency on inductive load Isolation Input / Output Temperature input / Output 2500 V RMS storage -40...+80 °C operating -20...+70 °C 1) Screw clamp Other characteristics Body material Wire size Spring clamp grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) 0.2-2.5 mm² (24-12 AWG) Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 9 mm (0.354 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending for 12 V DC) , (pending), , LRS , CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Reference standards 1) Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased. Dimensional drawings center of rail Screw clamp module center of rail Spring clamp module 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/52 5 Logic relays Product group picture 6 6/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays Table of contents Logic relays Logic relays 6/1 Product group picture 6/1 Table of contents 6/2 System overview 6/3 Approvals and marks 6/5 Ordering details - Stand alone logic relays 6/6 Ordering details - Expandable logic relays 6/7 Ordering details 6/8 Ordering details - Display systems 6/9 Technical data 6/10 Dimensional drawings 6/24 6 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/2 Logic relays System overview 6 Logic links instead of wiring Steps to the application of CL range –– CL range can be used easily, rapidly and comfortably without any time-consuming planning and programming. –– The user can discover the advantages and the benefit of these logic relays in no time at all. –– CL range provides for the control statements according to a simple circuit diagram. –– Setup, storage, simulation and documentation are performed using the compact and user-friendly CL-SOFT software (CL-LAS.PS002). S1 K1 S6 S4 S5 T1 T1 K1 K2 T1 1SVC 110 000 F 0554 Concept CL range logic relays are suitable for small and mediumsized control tasks and are able to substitute logic wiring in a quick and simple manner. They can be used for applications in control as well as for timing functions, e.g. –– in buildings, lighting systems, air-conditioning systems, general control functions, –– in small machines and systems or –– as stand-alone control module for small applications. Documentation (download from the internet) Logic relay manual: 1SVC440795M0100 Remote display manual: 1SVC440795M2100 Display system manual: 1SVC440795M1100 Software characteristics (CL-SOFT) –– Display on a PC monitor according to IEC, ANSI –– Different languages to choose from –– Easy installation on all Microsoft WindowsTM operating systems Technical data overview Logic relays – – 8 or 12 digital inputs – – 4 or 6 digital relay outputs – – optionally with 4 or 8 transistor outputs – – 128 rungs – – 3 contacts as n/o or n/c contacts in series plus 1 coil per rung – – optionally with 2 or 4 analog inputs (not 100-240 V AC version) – – power flow display for checking the circuit diagram (devices with display) – – expansions for local or remote level – – enclosure color RAL 7035 – – DIN rail mounting Display system –– useable as compact HMI logic relay –– fully graphic, backlit display module –– 12 digital inputs –– 4 digital relay outputs –– optionally with 4 transistor outputs –– 256 rungs –– 4 contacts as n/o or n/c contacts in series plus 1 coil per rung –– optionally with 4 analog inputs (not 100-240 V AC version) –– networking-compatible via CL-NET –– front panel mounting –– expansion for local Remote display –– Remote display up to a distance of 5 m –– Illustration of text and status displays –– Remote adjustment via keypad –– Front panel mounting Software – – 16 timing relays 0.01-99:59 h – – 16 counting relays for up-, down counting – – 8 weekly timer, 8 annual timers – – 16 analog value comparators – – 16 freely editable display texts – – 32 markers or auxiliary relays 6/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays System overview Display system R Compact HMI logic relay Expandable Stand alone CL-NET ... 4 10 2 2 Power 1a 1b 3 5 7 4 7 9 Power 8 1 3 3 2 1 6 6, 8b 5 5 8a 9 8b 1a 1b 2 3 4 5 6 7 8a 8b 9 2CDC 312 001 F0b08 8a 9 8b Logic relay CL-LS.. Expandable logic relay CL-LM.. Power supply CP-D... I/O expansion CL-LER.., CL-LET.. for logic relays CL-LM.. Coupler unit CL-LEC.. for remote expansion of logic relays CL-LM.. Memory module CL-LAS.MD003 for logic relays CL-LS.., CL-LM.. Connecting cable CL-LAS.TK001, CL-LAS.TK002 to connect PC CL-LINK plug CL-LAS.TK011 to connect expansion to logic relays CL-LM.. Remote display connection module CL-LDC.S.. Connecting cable CL-LAD.TK007 to connect a remote displays to a logic relay Display module CL-LDD.. 1 2 3 4 5 6 7 8 9 10 K 6 Stand alone with I/O module 2 1 3 1 2 Expansion of logic relays* Display module CL-LDD.. Display base module CL-LDC.LN.. Display I/O module CL-LDR.., CL-LDT.. Termination resistor CL-LAD.TK009 I/O expansion CL-LER.., CL-LET.. Coupler unit CL-LEC.. for remote expansion Memory module CL-LAD.MD004 for display base module Connecting cable CL-LAD.TK002, CL-LAD.TK003, CL-LAD.TK004 Connecting cable CL-LAD.TK001, CL-LAD.TK011 to connect PC CL-LINK plug CL-LAS.TK011 for expansion of logic relays CL-LM.. e.g. door of switchgear cabinet 3 2CDC 312 027 F0b06 4 6, 8b 2 2CDC 312 025 F0b06 Logic relays Display CL-LDD.. Remote display connection module CL-LDC.S.. incl. connecting cable Display base module CL-LDC.L.. Communication via CL-NET 1 5 2a 1 2 3 4 5 Logic relay CL-LM.. I/O expansion CL-LER.., CL-LET.. 2a local expansion 2b remote expansion Coupler unit CL-LEC.. for remote expansion of logic relays CL-LM.. CL-LINK plug CL-LAS.TK011 for expansion of logic relays CL-LM.. up to 30 m * max. 1 expansion per logic relay 5 5 4 3 1 1 2 3 4 5 2 3 1 2 2CDC 312 026 F0b06 4 CL-NET ... 2CDC 312 037 F0b07 2b 3 Display CL-LDD.. Display base module CL-LDC.LN.. for CL-NET Display I/O module CL-LDR.., CL-LDT.. Connecting cable CL-LAD.TK002, CL-LAD.TK003, CL-LAD.TK004 Termination resistor CL-LAD.TK009 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/4 Logic relays Approvals and marks CL-LAD CL-LAS Accessories CL-LDT CL-LDR CL-LDC CL-LDD Display system CL-LEC CL-LET CL-LER CL-LMT CL-LMR Expansions B UL J J J J J J J J J J J J 1) J 2) F CAN/CSA C22.2 No.14 J J J J J J J J J J J J 1) J 2) J J J J J J J J J J J J 1) J 2) J J J J J J k k J J C CAN/CSA C22.2 No.213 (hazardous locations) GL R EAC k k k k P Lloyds Register J J J J a CE J J J J J J J J J J b C-Tick k k k k k k k k k k F 6 CL-LST Approvals Logic relays CL-LSR J existing j pending k k k 3) J 4) k 3) J J k 4) k k J J J k k k J Marks 1) 2) 3) 4) not not not not for: for: for: for: CL-LAS-PS002, CL-LAS.TD001, CL-LAS.FD001, CL-LAS.TK002, CL-LAS.TK011 CL-LAD.TK006, CL-LAD.TK011, CL-LAD.FD002 CL-LDC.SDC2, CL-LDC.SAC2, CL-LDC.LAC2, CL-LDC.LNAC2 CL-LDR.16AC2 6/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays Ordering details - Stand alone logic relays Ordering details - Logic relays stand alone 2CDC 281 034 F0006 Rated operational voltage 24 V AC 100-240 V AC CL-LSR 12 V DC 24 V DC 2CDC 281 033 F0006 24 V DC Display Timer Input / + Output Keypad Type J CL-LSR.C12AC1 J J J J J J J J J J J J J J J J Order code Price 1 pce Weight (1 pce) kg (lb) 1SVR440712R0300 CL-LSR.CX12AC1 1SVR440712R0200 CL-LSR.12AC2 1SVR440713R0100 CL-LSR.C12AC2 1SVR440713R0300 8 inputs / 4 CL-LSR.CX12AC2 1SVR440713R0200 relay outputs CL-LSR.C12DC1 1SVR440710R0300 0.20 (0.44) CL-LSR.CX12DC1 1SVR440710R0200 CL-LSR.12DC2 1SVR440711R0100 CL-LSR.C12DC2 1SVR440711R0300 CL-LSR.CX12DC2 1SVR440711R0200 8 inputs / 4 transistor outputs CL-LST.C12DC2 1SVR440711R1300 CL-LST.CX12DC2 1SVR440711R1200 6 CL-LST Ordering details - Display modules 2CDC 281 028 F0006 Rated operational voltage Type Order code Price 1 pce Weight (1 pce) kg (lb) - Graphic display 132 x 64 pixel CL-LDD.XK 1SVR440839R4500 0.14 (0.30) - Graphic display 132 x 64 pixel, with keypad CL-LDD.K 1SVR440839R4400 0.13 (0.29) 1SVR440841R0000 0.16 (0.36) 1SVR440843R0000 0.16 (0.36) 24 V DC 100-240 V AC CL-LDC.SDC2 Module to displace the display from the logic relay, incl. connecting cable CL-LAD. TK007, 5m, lenght adaptable CL-LDC.SAC2 2CDC 281 017 F0007 CL-LDD.K Description CL-LDC.S.. 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/6 Logic relays Ordering details - Expandable logic relays 2CDC 311 036 F0006 Ordering details - Logic relays expandable Rated operational voltage 24 V AC 100-240 V AC CL-LMR 12 V DC 24 V DC 2CDC 311 037 F0007 24 V DC 6 Type J CL-LMR.C18AC1 1SVR440722R0300 CL-LMR.CX18AC1 1SVR440722R0200 CL-LMR.C18AC2 1SVR440723R0300 CL-LMR.CX18AC2 1SVR440723R0200 CL-LMR.C18DC1 1SVR440720R0300 CL-LMR.CX18DC1 1SVR440720R0200 CL-LMR.C18DC2 1SVR440721R0300 CL-LMR.CX18DC2 1SVR440721R0200 12 inputs, CL-LMT.C20DC2 8 transistor CL-LMT.CX20DC2 outputs 1SVR440721R1300 J J J J J J J J J J J J J J 12 inputs / 6 relay outputs Order code Price 1 pce Weight (1 pce) kg (lb) 0.36 (0.79) 0.36 (0.79) 1SVR440721R1200 Ordering details - Expansions Rated operational voltage - CL-LER Display Timer Input / + Output Keypad Description Type Order code Price 1 pce 2 relay outputs 100-240 V AC Weight (1 pce) kg (lb) CL-LER.2O 1SVR440709R5000 0.07 (0.15) CL-LER.18AC2 1SVR440723R0000 0.26 (0.57) CL-LER.18DC2 1SVR440721R0000 0.22 (0.49) 12 inputs, 6 relay outputs 2CDC 311 038 F0006 24 V DC 24 V DC 12 inputs, 8 transistor outputs CL-LET.20DC2 1SVR440721R1000 0.21 (0.46) - Coupler unit for remote expansion with a distance of up to 30 m CL-LEC.CI000 1SVR440709R0000 0.07 (0.15) CL-LEC 6/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays Ordering details Ordering details - CL-LA... Description Type Order code Price 2CDC 311 012 F0007 1 pce 2CDC 311 014 F0007 CL-LAS.PS002 2CDC 311 013 F0007 CL-LAS.TK001 Weight (1 pce) kg (lb) Software for programming and control of CL range devices. Installation CD-ROM for Microsoft WindowsTM. CL-LAS.PS002 1SVR440799R8000 0.10 (0.21) Memory module for logic relays Memory size: 32 kB CL-LAS.MD003 1SVR440799R7000 0.02 (0.04 Cable with serial interface to connect PC and logic relay. Length: 2 m CL-LAS.TK001 1SVR440799R6000 0.10 (0.22) Cable with USB interface to connect PC and logic relay. Length: 2 m CL-LAS.TK002 1SVR440799R6100 0.06 (0.13) Cable for point-to-point connection of remotedisplay connection module and logic relay, length: 5m, adaptable CL-LAD.TK007 1SVR440899R6600 0.20 (0.44) Fixing brackets for screw mounting of logic relay, expansion, display base module CL-LAS.FD001 1SVR440799R5000 0.01 (0.01) Spare plug (CL-LINK) for connection of logic relay to expansion CL-LAS.TK011 1SVR440799R5100 0.10 (0.22) Primary switch mode power supplies, Rated input voltage: 100-240 V AC CP-D 24/0.421) Rated output voltage/current: 24 V DC / 0.42 A 1SVR427041R0000 0.06 (0.13) Primary switch mode power supplies, Rated input voltage: 100-240 V AC Rated output voltage/current: 24 V DC / 1.3 A 1SVR427043R0100 0.19 (0.41) 1) 2) CP-D 24/1.32) replaces CL-LAS.SD001, technical data see chapter “Primary switch mode power supplies” replaces CL-LAS.SD002, technical data see chapter “Primary switch mode power supplies” CL-LAS.MD003 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/8 6 Logic relays Ordering details - Display systems Ordering details - Display systems 2CDC 311 028 F0006 Rated operational voltage Price 1 pce Weight (1 pce) kg (lb) CL-LDD.XK 1SVR440839R4500 0.14 (0.30) - Display module Graphic display 132 x 64 pixel, with keypad CL-LDD.K 1SVR440839R4400 0.13 (0.29) CL-LDC.LDC2 1SVR440821R0000 CL-LDC.LAC2 1SVR440823R0000 CL-LDC.LNDC2 1SVR440821R1000 CL-LDC.LNAC2 1SVR440823R1000 CL-LDR.16AC2 1SVR440853R0000 CL-LDR.16DC2 1SVR440851R0000 CL-LDR.17DC2 1SVR440851R2000 0.17 (0.38) CL-LDT.16DC2 1SVR440851R1000 0.14 (0.30) CL-LDT.17DC2 1SVR440851R3000 0.14 (0.30) Type Order code 24 V DC 100-240 V AC 100-240 V AC 24 V DC 2CDC 311 031 F0006 Order code - 100-240 V AC 6 Type Display module Graphic display 132 x 64 pixel 24 V DC CL-LDD.K Description 24 V DC 24 V DC 24 V DC CL-LDC.LN.. Display base module CPU / power supply Display base module CPU / power supply, networking-compatible (CL-NET) Display I/O module 12 inputs, 4 relay outputs Display I/O module 12 inputs, 4 relay outputs, 1 analog output Display I/O module 12 inputs, 4 transistor outputs Display I/O module 12 inputs, 4 transistor outputs, 1 analog output 0.16 (0.36) 0.17 (0.38) 0.17 (0.38) Ordering details - CL-LAD... Description Price 2CDC 311 018 F0007 1 pce 2CDC 311 019 F0007 CL-LAD.MD004 Memory module for display base modules Memory size: 256 kB CL-LAD.MD004 1SVR440899R7000 0.02 (0.03) Cable with serial interface to connect PC and display base module CL-LAD.TK001 1SVR440899R6000 0.11 (0.23) Cable with USB interface to connect PC and display base module CL-LAD.TK011 1SVR440899R6700 Network cable (CL-NET) to connect 2 display base modules Length: 0.3 m CL-LAD.TK002 1SVR440899R6100 0.05 (0.12) Network cable (CL-NET) to connect 2 display base modules Length: 0.8 m CL-LAD.TK003 1SVR440899R6200 0.07 (0.14) Network cable (CL-NET) to connect 2 display base modules Length: 1.5 m CL-LAD.TK004 1SVR440899R6300 0.08 (0.18) Cable for point-to-point connection of remote display connection modules and display base module, length adaptable, Length: 5 m CL-LAD.TK005 1SVR440899R6400 0.20 (0.44) Cable for point-to-point connection of 2 display base modules, length adaptable. Length: 5 m CL-LAD.TK006 1SVR440899R6500 0.12 (0.26) Termination resistor, content: 2 pieces CL-LAD.TK009 1SVR440899R6900 0.01 (0.02) Protective cover, transparent, for harsh environmental conditions and application in the food industry CL-LAD.FD001 1SVR440899R1000 0.03 (0.07) Protective cover, transparent and sealable CL-LAD.FD011 1SVR440899R2000 0.03 (0.07) Assembly tool for mounting of display modules CL-LAD.FD002 1SVR440899R3000 2CDC 311 020 F0006 CL-LAD.TK001 Weight (1 pce) kg (lb) CL-LAD.TK002 6/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type CL-LSR.C...12DC1 CL-LSR.C...12AC1 CL-LSR...12AC2 Input circuit - supply circuit Rated operational voltage U e CL-LSR....12DC2 CL-LST.C...12DC2 12 V DC 24 V DC 24 V AC 100-240 V AC Rated operational voltage tolerance Operational voltage range Rated frequency Rated frequency tolerance Residual ripple Input current at 12 V DC at 24 V DC at 24 V AC at 115/120 V AC (60 Hz) at 230/240 V AC (50 Hz) Power failure buffering (IEC/EN 61131-2) Power dissipation at 12 V DC at 24 V DC at 24 V AC at 115/120 V AC at 230/240 V AC -15...+30 % 10.2-15.6 V DC 0 Hz m5% typ. 140 mA 10 ms typ. 2 W - -15...+20 % 20.4-28.8 V DC -15...+10 % 20.4-26.4 V AC 50/60 Hz ±5 % typ. 200 mA 20 ms typ 5 VA - Type CL-LMR.C...18DC1 CL-LMR.C...18AC1 CL-LMR.C...18AC2 Input circuit - supply circuit Rated operational voltage U e CL-LMR.C...18DC2 CL-LMT.C...20DC2 12 V DC 24 V DC 24 V AC 100-240 V AC Rated operational voltage tolerance Operational voltage range Rated frequency Rated frequency tolerance Residual ripple Input current at 12 V DC at 24 V DC at 24 V AC at 115/120 V AC (60 Hz) at 230/240 V AC (50 Hz) Power failure buffering (IEC/EN 61131-2) Power dissipation at 12 V DC at 24 V DC at 24 V AC at 115/120 V AC at 230/240 V AC -15...+30 % 10.2-15.6 V DC 0 Hz m5% typ. 200 mA 10 ms typ. 3.5 W - -15...+20 % 20.4-28.8 V DC -15...+10 % 20.4-26.4 V AC 50/60 Hz ±5 % typ. 300 mA 20 ms typ. 7 VA - Type CL-LER.18DC2 CL-LET.20DC2 CL-LER.18AC2 Rated operational voltage U e 24 V DC 100-240 V AC Rated operational voltage tolerance Operational voltage range Rated frequency Rated frequency tolerance Residual ripple Input current at 24 V DC at 115/120 V AC (60 Hz) at 230/240 V AC (50 Hz) Power failure buffering (IEC/EN 61131-2) Power dissipation at 24 V DC at 115/120 V AC at 230/240 V AC -15...+20 % 20.4-28.8 V DC 0 Hz m5% typ. 140 mA 10 ms typ. 3.4 W - -15...+10 % 85-264 V AC 50/60 Hz ±5 % typ. 70 mA typ. 35 mA 20 ms typ. 10 VA typ. 10 VA Input circuit - supply circuit typ. 80 mA typ. 2 W - typ. 140 mA typ. 3.5 W - 85-264 V AC typ. 40 mA typ. 20 mA typ. 5 VA typ. 5 VA 6 85-264 V AC typ. 70 mA typ. 35 mA typ. 10 VA typ. 10 VA 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/10 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type CL-LSR.C...12DC1 Input circuit - Digital inputs 12 V DC Number Inputs can be used as analog inputs Indication of operational states Electrical isolation from voltage supply between digital inputs from the outputs Rated operational voltage U e U e on „0“ signal 8 2 (I7, I8) LCD-Display (if existing) no no yes 12 V DC 24 V DC 4 V DC (I1-I8) < 5 V DC (I1-I8) U e on „1“ signal 8 V DC (I1-I8) Rated frequency Input current on „1“ signal 3.3 mA (at 12 V DC, I1-I6), 1.1 mA (at 12 V DC, I7, I8) CL-LSR....12DC2 CL-LST.C...12DC2 24 V DC > 15 V DC (I1-I6), > 8 V DC (I7, I8) 3.3 mA (at 24 V DC, I6-I7), 2.2 mA (at 24 V DC, I7, I8) 6 Time delay from „0“ to „1“ debounce ON 20 ms debounce OFF typ. 0.3 ms (I1-I6), typ. 0.35 ms (I7, I8) debounce ON 20 ms Time delay from „1“ to „0“ debounce OFF typ. 0.3 ms (I1-I6), typ. 0.15 ms (I7, I8) typ. 0,25 ms (I1-I8) - CL-LSR.C...12AC1 CL-LSR.C...12AC2 24 V AC 115 / 230 V AC - 24 V AC 0-6 V AC (sinusoidal) 79-264 V AC (sinusoidal) 80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz) 80 ms (at 50 Hz, I1-I6), 66 2/3 ms (at 60 Hz, I1-I6) 160 ms (at 50 Hz, I7, I8), 150 ms (at 60 Hz, I7, I8) 20 ms (at 50 Hz, I1-I6), 16 2/3 ms (at 60 Hz, I1-I6) 100 ms (at 50 Hz, I7. I8), 100 ms (at 60 Hz, I7, I8) 40 m (I1-I6), 100 m (I7, I8) - 6x0.25 mA (at 115 V AC, 60 Hz, I1-I6), 6x0.5 mA (at 230 V AC, 50 Hz, I1-I6) 2x4 mA (at 115 V AC, 60 Hz, I7, I8), 2x6 mA (at 230 V AC, 50 Hz, I7, I8) 80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz) 20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz) 20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz) Cable length (unshielded) Maximum cable length per input 100 m - 40 m Frequency counter 2 (I3, I4) < 1 kHz square-wave 1:1 2 (I1, I2) < 1 kHz square-wave 1:1 < 20 m - Rapid counter inputs Cable length (shielded) Input circuit - Analog inputs Number Electrical isolation Input type Signal range Resolution Input impedance Accuracy of the actual value Conversion time analog/digital Input current Cable length (shielded) Number counting frequency pulse shape pulse / pause ratio Number counting frequency pulse shape pulse / pause ratio from voltage supply from the digital inputs from the outputs from PC interface, memory module, CL-NET, CL-LINK analog digital two CL devices within one device Input delay ON Input delay OFF 0-40 V AC (sinusoidal) > 9.5 V DC, 14-26.4 V AC (sinusoidal) (I1-I6), > 7 V AC (sinusoidal) (I7,I8) 50-60 Hz 4 mA (at 24 V AC, 50 Hz, I1-I6), 2 mA (at 24 V AC, 50 Hz, I7,I8), 2 mA (at 24 V DC, I7, I8) 2 (I7, I8) no no yes no - DC voltage 0-10 V DC 0.01 V 0.01 V; 10 Bit (value 1-1023) 11.2 kq ±3 % ±2 %, ±0.12 V 20 ms each cycle < 1 mA < 30 m - 6/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type CL-LMR.C...18DC1 Input circuit - Digital inputs 12 V DC Number Inputs can be used as analog inputs Indication of operational states Electrical isolation from voltage supply between digital inputs from the outputs from PC interface, memory module, CL-NET, CL-LINK Rated operational voltage U e U e on „0“ signal 12 4 (I7, I8, I11, I12) LCD-Display (if existing) no no yes no 12 V DC 4 V DC (I1-I12) U e on „1“ signal 8 V DC (I1-I12) Rated frequency Input current on „1“ signal 3.3 mA (at 12 V DC, I1-I6, I9-I12), 1.1 mA (at 12 V DC, I7, I8) Time delay from „0“ to „1“ Time delay from „1“ to „0“ Cable length (unshielded) Maximum cable length per input Frequency counter Rapid counter inputs Cable length (shielded) Input circuit - Analog inputs Number Electrical isolation Input type Signal range Resolution Input impedance Accuracy of the actual value Conversion time analog/digital Input current Cable length (shielded) CL-LMR.C...18DC2 CL-LMT.C...20DC2 24 V DC from voltage supply from the digital inputs from the outputs from PC interface, memory module, CL-NET, CL-LINK analog digital two CL devices within one device Input delay ON Input delay OFF CL-LMR.C...18AC2 24 V AC 115 / 230 V AC - yes 24 V DC 24 V AC < 5 V DC 0-6 V AC (sinusoidal) (I1-I12, R1-R12) > 15 V DC (I1-I6, I9, I10) > 9.5 V DC, > 8 V DC (I7, I8, I11, I12) 14-26.4 V AC (sinusoidal) (I1-I6, I9, I10) > 7 V AC (sinusoidal) (I7,I8; I11, I12) 50-60 Hz 3.3 mA 4 mA (at 24 V DC, I1-I6, I9, I10), (at 24 V AC, 50 Hz, 2.2 mA I1-I6, I9, I10), (at 24 V DC, I7, I8, I11, I12) 2 mA (at 24 V AC, 50 Hz, I7, I8, I11, I12), 2 mA (at 24 V DC, I7, I8, I11, I12) debounce ON 20 ms debounce OFF typ. 0.3 ms (I1-I6, I9, I10), typ. 0.25 ms typ. 0.35 ms (I7, I8, I11, I12) debounce ON 20 ms debounce OFF typ. 0.4 ms (I1-I6, I9, I10), typ. 0.35 ms (I7, I8, I11, I12) 100 m number counting frequency pulse shape pulse / pause ratio number counting frequency pulse shape pulse / pause ratio CL-LMR.C...18AC1 2 (I3, I4) < 1 kHz square-wave 1:1 2 (I1, I2) < 1 kHz square-wave 1:1 < 20 m 0-40 V AC (sinusoidal) 79-264 V AC (sinusoidal) 6x0.25 mA (at 115 V AC, 60 Hz, I1-I6), 6x0.5 mA (at 230 V AC, 50 Hz, I1-I6) 2x4 mA (at 115 V AC, 60 Hz, I7, I8), 2x6 mA (at 230 V AC, 50 Hz, I7, I8), 4x0.25 mA (at 115 V AC, 60 Hz, I9-I12), 4x0.5 mA (at 230 V AC, 50 Hz, I9-I12) 80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz) 20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz) 6 80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz) 20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz) max. 40 m, typ. 40 m (I9, I10) - typ. 40 m (I1-I6, I9-I12), typ. 100 m (I7, I8) - 4 (I7, I8, I11, I12) no no yes no - DC voltage 0-10 V DC 0.01 V 0.01 V; 10 Bit (value 1-1023) 11.2 kq ±3 % ±2 %, ±0.12 V 20 ms each cycle < 1 mA < 30 m - 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/12 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type Input circuit - Digital inputs Number Inputs can be used as analog inputs Indication of operational states Electrical isolation from voltage supply between digital inputs from the outputs from PC interface, memory module, CL-NET, CL-LINK Rated operational voltage U e U e on „0“ signal 12 no no yes no CL-LER.18DC2, CL-LET.20DC2 24 V DC 24 V DC < 5 V DC (I1-I12, R1-R12) U e on „1“ signal - 6 Rated frequency Input current on „1“ signal Time delay from „0“ to „1“ 3.3 mA (at 24 V DC, R1-R12) debounce ON 20 ms debounce OFF typ. 0.25 ms (R1-R12) Time delay from „1“ to „0“ debounce ON 20 ms debounce OFF - Cable length (unshielded) Maximum cable length per input 100 m - 6/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 CL-LER.18AC2 115 / 230 V AC 0-40 V AC (sinusoidal) 79-264 V AC (sinusoidal) 50-60 Hz 12x0.25 mA (at 115 V AC, 60 Hz, R1-R12), 12x0.5 mA (at 230 V AC, 50 Hz, R1-R12) 80 ms (at 50 Hz, I1-I12, R1-R12), 66 2/3 ms (at 60 Hz, I1-I12, R1-R12) 20 ms (at 50 Hz, I1-I12, R1-R12), 16 2/3 ms (at 60 Hz, I1-I12, R1-R12) 80 ms (at 50 Hz, I1-I12, R1-R12), 66 2/3 ms (at 60 Hz, I1-I12, R1-R12) 20 ms (at 50 Hz, I1-I12, R1-R12), 16 2/3 ms (at 60 Hz, I1-I12, R1-R12) typ. 40 m (I1-I6, I9-I12, R1-R12), typ. 100 m (I7, I8) Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type CL-LSR... 4 6 1 not permissible circuit-breaker B16 or fuse 8 A (slow-acting) from voltage supply yes from the inputs yes from PC interface, memory module, no CL-NET, CL-LINK protective separation 300 V AC basic isolation 600 V AC 10x106 switching cycles conventional thermal current (10 A UL) 8 A recommended for load 12 V AC/DC > 500 mA short-circuit proof cos j = 1; 16 A characteristic B16 at 600 A short-circuit proof cos j = 0,5 up to 0,7; 16 A characteristic B16 at 900 A Rated impulse withstand voltage U imp 6 kV contact-coil Rated operational voltage U e 250 V AC Rated insulation voltage U i Protective separation (EN 50178) Making capacity Breaking capacity Incandesent lamp load Fluorescent lamp load Switching frequency UL/CSA Continuous current at 240 V Continuous current at 24 V AC DC CL-LER.2O CL-LER... Output circuit - Relay outputs Number Outputs in groups of Parallel switching of outputs to increase capacity Fusing of the output relay Electrical isolation Mechanical lifetime Rung CL-LMR... 2 2 6 250 V AC between coil and contact between two contacts AC-15, 250 V AC, 3 A (600 ops./h) DC13, L/R m 150 ms, 24 V DC, 1 A (500 ops./h) AC-15, 250 V AC, 3 A (600 ops./h) DC13, L/R m 150 ms, 24 V DC, 1 A (500 ops./h) 1000 W at 230/240 V AC 500 W at 115/120 V AC 10 x 58 W at 230/240 V AC with electrical control gear 10 x 58 W at 230/240 V AC uncompensated 1 x 58 W at 230/240 V AC conventional compensated mechanical operations switching frequency resistive load / lamp load inductive load 300 V AC 300V AC 300.000 switching cycles 200.000 switching cycles 300.000 switching cycles 200.000 switching cycles 25.000 switching cycles 25.000 switching cycles 25.000 switching cycles 25.000 switching cycles 25.000 switching cycles 10x10 6 10 Hz 2 Hz 0.5 Hz 10 A AC 8 A DC Utilization catagory (Control Circuit Rating B 300 Light Pilot Duty Codes) max. rated operational voltage 300 V AC max. continuous thermal current cos j = 5 A 1 at B 300 max. making / breaking apparent power 3600/360 VA (Make/Break) cos j ≠ 1 at B 300 Utilization catagory (Control Circuit Rating R 300 Light Pilot Duty Codes) max. rated operational voltage 300 V DC max. continuous thermal current at R 300 1 A max. making / breaking apparent power 28/28 VA (Make/Break) at R 300 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/14 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type Output circuit - Transistor outputs Number Rated operational voltage U e Operational voltage range Residual ripple Supply current Reverse voltage protection CL-LST... 4 24 V DC on „0“ signal on „1“ signal Electrical isolation CL-LMT... CL-LET... 8 20.4-28.8 V DC m5% typ. 9 mA / max. 16 mA typ. 18 mA / max. 32 mA typ. 12 mA / max. 22 mA typ. 24 mA / max. 44 mA yes (Attention: If supply voltage is reversed, applying voltage at the outputs, causes a short circuit.) yes yes - from voltage supply from the inputs from PC interface, memory module, CL-NET, CL-LINK Rated operational current I e on„1“ signal DC max. 0.5 A 6 Lamp load without R v 5W Residual current on „0“ signal per channel Max. output voltage on „0“ signal at external load < 10 Mq on „1“ signal at Ie = 0.5 A Short-circuit protection Short-circuit tripping current for R a m 10 mq Total short-circuit current Peak short-circuit current Thermal tripping Max. switching frequency with constant resistive load R L < 100 kq (depending on active channels and their load) Parallel connection of outputs with resistive load, inductive load with external suppressor, combination within one group number of outputs max. total current < 0.1 mA 2.5 V U = Ue - 1 V yes, thermal (analysis results from diagnosis input I16, I15; R15, R16) 0.7 A m I e m 2 A per output 8A 16 A 16 A 32 A yes 40.000 switching cycles/h Indication of operational states of the outputs Inductive load1) without external suppressor T0.95 = 1 ms, utilization factor R = 48 q, duty time L = 16 mH max. switching frequency f = 0,5 Hz (max. duty time = 50 %) DC13, utilization factor T0.95 = 72 ms, duty time R = 48 q, max. switching frequency f = 0,5 Hz L = 1.15 H (max. duty time = 50 %) T0.95 = 15 ms, utilization factor R = 48 q, duty time L = 0.24 H max. switching frequency f = 0,5 Hz (max. duty time = 50 %) Inductive load1) with external suppressor demand factor duty time max. switching frequency max. duty time group 1: Q1-Q4 group 1: Q1-Q4, group 2: Q5-Q8 group 1: S1-S4, group 2: S5-S8 max. 4 2 A (Attention! Outputs must be actuated simultaneously and for the same length of time.) LCD-Display (if existing) 0.25 g 100 % 1500 switching cycles 0.25 g 100 % 1500 switching cycles 0.25 g 100 % 1500 switching cycles 1g 100 % depends on suppressor 1) For inductive loading, without external suppression of the transistor outputs, the following applies: T0.95 = time in ms, until 95 % of the steady-state current is achieved. T0.95 3 × T0.65 = 3 × L/R. Data transfer rate in the CL-NET network: bus lengths of 40 m and over only attainable with cables with additional cross-section and connection adapter. 6/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type CL-LSR..., CL-LST... General data Dimensions (W x H x D) Max. tightening torque Environmental data Ambient temperature range rigid 0.2-4 mm 2 (22–12 AWG) fine-strand with wire end 0.2-2.5 mm 2 (22–12 AWG) ferrule 0.6 Nm LCD-Display (clearly legible) Condensation Humidity, no condensation (IEC/EN 60068-2-30) Air pressure (operation) Degree of protection (IEC/EN 60529) Vibration (IEC/EN 60068-2-6) Shock resistance (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27) Drop (IEC/EN 60068-2-31) height of fall Free fall, packaged (IEC/EN 60068-2-32) Insulation data Overvoltage category Pollution degree (DIN EN 60947) Rating of air and creepage distances Insulation resistance Standards Standards and directives Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) IEC/EN electromag. field (HF radiation resistance) IEC/EN fast transients (Burst) IEC/EN powerful impulses (Surge) IEC/EN HF line emission Interference suppression (EN 55011, EN 55022) Real time clock Back-up time Accuracy Repeat accuracy of the time relay Accuracy (from value) Resolution operation -25...+55 °C, cold acc. to IEC 60068-2-1, heat acc. to IEC 60068-2-2 storage -40...+70 °C 0...+55 °C avoid condensation with suitable methods 5-95 % 795-1080 hPa IP20 10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant acceleration 2 g) 18 Shocks 50 mm 1m 6 II 2 EN 50178, UL 508, CSA C22.2, No. 142 EN 50178 EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27 61000-4-2 61000-4-3 61000-4-4 61000-4-5 Level 3 (air discharge 8 kV, contact discharge 6 kV) 10 V/m Level 3 (supply cable 2 kV, signal lines 2 kV) supply cable symmetrical (AC) 2 kV, Level 2 (supply cable symmetrical (DC) 0.5 kV) IEC/EN 61000-4-6 10 V class B see diagram typ. ±5 (±0.5 h/year) - ±1 range „S“ 10 ms range „M:S“ 1 s range „H:M“ 1 min Retention behaviour Write cycles of retention memory (minimum) - 200 180 160 140 120 100 80 60 40 20 0 0 - 2CDC 312 023 F0206 1.000.000 (10 6) Buffer time (hours) Technical diagram Back-up time of the real time clock CL-LER.2O CL-LEC.CI000 71.5 mm x 90 mm x 107.5 mm x 90 mm x 35.5 mm x 90 mm x 58 mm 58 mm 58 mm (2.81 inch x 3.54 inch x (4.23 inch x 3.54 inch x (1.40 inch x 3.54 inch x 2.28 inch) 2.28 inch) 2.28 inch) 0.2 kg (0.44 lb) 0.3 kg (0.66 lb) 0.07 kg (0.15 lb) DIN rail (IEC/EN 60715), 35 mm or screw mounting with fixing brackets CL-LAS.FD001 (accessories) horizontal / vertical Weight Mounting Mounting position Electrical connection Wire size CL-LMR... CL-LMT.. CL-LET.., CL-LER.18.. 25 ˚C 55 ˚C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Operating time (years) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/16 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type Input circuit - Supply circuit Power failure buffering (IEC/EN 61131-2) General data Dimensions (W x H x D) CL-LDD... 10 ms with keypad: 86.5 x 86.5 x 21.5 mm (3.41 x 3.41 x 0.85 inch) without keypad: 86.5 x 86.5 x 20 mm (3.41 x 3.41 x 0.79 inch) 0.13 kg (0.29 lb) 2 x 22.5 mm, with 2 retainers screwed horizontal / vertical Weight Mounting Mounting position Environmental data Ambient temperature range operation -25...+55 °C (cold acc. to IEC 60068-2-1, heat acc. to IEC 60068-2-2) storage -40...+70 °C -5...+50 °C, -10...0 °C (with backlit / continuous operation) avoid condensation with suitable methods 5-95 % 795-1080 hPa IP65 10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant acceleration 2 g) 18 Shocks 50 mm 1m LCD-Display (clearly legible) 6 Condensation Humidity, no condensation (IEC/EN 60068-2-30) Air pressure (operation) Degree of protection (IEC/EN 60529) Vibration (IEC/EN 60068-2-6) Shock resistance (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27) Drop (IEC/EN 60068-2-31) height of fall Free fall, packaged (IEC/EN 60068-2-32) Insulation data Pollution degree (DIN EN 60947) Rating of air and creepage distances Insulation resistance Standards Standards and directives Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) electromag. field (HF radiation resistance) fast transients (Burst) powerful impulses (Surge) HF line emission Interference suppression (EN 55011, EN 55022) 3 EN 50178, UL 508, CSA 22.2, No 142 EN 50178 EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, IEC 60068-2-6, IEC 60068-2-27 IEC/EN IEC/EN IEC/EN IEC/EN 61000-4-2 61000-4-3 61000-4-4 61000-4-5 Level 3 (air discharge 8 kV, contact discharge 6 kV) 10 V/m Level 3 (supply cable 2 kV, signal lines 2 kV) Level 3 (supply cable symmetrical 2 kV, CL-LDC.L...AC2) Level 2 (0.5 kV supply cable symmetrical, CL-LDC.L...AC2) IEC/EN 61000-4-6 10 V class B 6/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type Input circuit - Supply circuit Rated operational voltage U e Rated operational voltage tolerance Operational voltage range Frequency Frequency tolerance Residual ripple Input current at 24 V DC at 115/120 V AC (60 Hz) at 230/240 V AC (50 Hz) Power failure buffering (IEC/EN 61131-2) Power dissipation at 24 V DC at 115/120 V AC at 230/240 V AC Network - point-to-point connection Number of stations Data transfer rate CL-LS..., CL-LM... CL-LDD Distance Electrical isolation to voltage supply to connected device Termination system Network - CL-NET Number of stations Data transfer rate 6m 25 m 40 m 125 m 300 m 700 m 1000 m Electrical isolation to voltage supply to inputs to outputs to PC interface, memory module, CL-NET, CL-LINK Bus terminator (first and last station) Termination system General data Dimensions (W x H x D) Weight Mounting Mounting position Electrical connection - Supply circuit Wire size fine-strand with wire end ferrule rigid Electrical connection - Data cable Wire size fine-strand with wire end ferrule rigid CL-LDC.SDC2 CL-LDC.SAC2 CL-LDC.LDC2 CL-LCD.LAC2 CL-LDC.LNDC2 CL-LDC.LNAC2 24 V DC 100-240 V AC 24 V DC 100-240 V AC 24 V DC 100-240 V AC -15...+20 % 20.4-28.8 V DC 0 Hz m5% typ. 185 mA 10 ms 1.5 W - -15...+10 % 85-264 V AC 50/60 Hz ±5% typ. 90 mA typ. 60 mA -15...+20 % 20.4-28.8 V DC 0 Hz m5% typ. 200 mA - -15...+10 % 85-264 V AC 50/60 Hz ±5% typ. 90 mA typ. 60 mA -15...+20 % 20.4-28.8 V DC 0 Hz m5% typ. 200 mA - -15...+10 % 85-264 V AC 50/60 Hz ±5% typ. 90 mA typ. 60 mA typ. 11 VA typ. 15 VA 3.4 W - typ. 11 VA typ. 15 VA 3.4 W - typ. 11 VA typ. 15 VA 1 9.6 kBaud 19.2 kBaud max. 5 m yes yes spring-type terminal - max. 1 - - - 6 max. 8 1000 kBit/s 500 kBit/s 250 kBit/s 125 kBit/s 50 kBit/s 20 kBit/s 10 kBit/s yes yes yes yes yes RJ45, 8 pole 75 x 58 x 36.2 mm (2.95 x 2.28 x 1.43 inch) 0.164 kg (0.36 lb) plugged onto CL-LDD 107.5 x 90 x 30 mm (4.23 x 3.54 x 1.18 inch) 0.145 kg (0.32 lb) plugged onto CL-LDD or on DIN rail (IEC/EN 60715) 0.2 mm 2 / 2.5 mm 2 (24-12 AWG) 0.2 mm 2 / 4 mm 2 (24-12 AWG) 0.08 mm 2 / 1.5 mm 2 (28-12 AWG) 0.08 mm 2 / 2.5 mm 2 (28-12 AWG) - 0.2 mm 2 / 2.5 mm 2 (24-12 AWG) 0.2 mm 2 / 4 mm 2 (24-12 AWG) Environmental data Ambient temperature range operation -25...+55 °C (cold acc. to IEC 60068-2-1, heat acc. to IEC 60068-2-2) storage -40...+70 °C Condensation avoid condensation with suitable methods Humidity, no condensation (IEC/EN 60068-2-30) 5-95 % Air pressure (operation) 795-1080 hPa Degree of protection (IEC/EN 60529) IP20 Vibration (IEC/EN 60068-2-6) 10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant acceleration 2 g) 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/18 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type CL-LDC. Shock (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27) Drop (IEC/EN 60068-2-31) height of fall Free fall, packaged (IEC/EN 60068-2-32) Insulation data Degree of protection (DIN EN 60947) Rating of air and creepage distances Isolation resistance Standards Standards and directives Electromagnetical compatibility Interference immunity electrostatic discharge (ESD) electromag. field (HF radiation resistance) fast transients (Burst) powerful impulses (Surge) CL-LDC. CL-LCD. CL-LDC. CL-LDC. SAC2 LDC2 LAC2 LNDC2 LNAC2 2 EN 50178, UL 508, CSA 22.2, No 142 EN 50178 EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, IEC 60068-2-6, IEC 600682-27 Level 3 (air discharge 8 kV, contact discharge 6 kV) 10 V/m Technical diagram Back-up time of the real time clock 200 180 160 140 120 100 80 60 40 20 0 0 2CDC 312 023 F0206 Level 3 (supply cable 2 kV, signal lines 2 kV) Level 3 (supply cable symmetrical 2 kV, CL-LDC.L...AC2) Level 2 (1 kV supply cable Level 2 (0.5 kV supply cable symmetrical, CL-LDC.L...AC2) symmetrical) HF line emission IEC/EN 61000-4-6 10 V Interference suppression (EN 55011, EN 55022) class B Real time clock Back-up time see diagram Accuracy typ. ± 5 s/day (± 0,5 h/year) Repeat accuracy of the time relay Accuracy (from value) ± 0.02 % Resolution range „S“ 5 ms range „M:S“ 1s range „H:M“ 1 min Retention behaviour Write cycles of retention memory (minimum) 1010 (read/ write cycles) Buffer time (hours) 6 IEC/EN 61000-4-2 IEC/EN 610004-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 CL-LDC. SDC2 18 Shocks 50 mm 1m 25 ˚C 55 ˚C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Operating time (years) 6/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type Input circuit - Digital inputs Number Inputs can be used as analog inputs Indication of operational states Electrical isolation Rated operational voltage U e CL-LD...16DC2 from supply voltage from digital inputs from the outputs from PC interface, memory module, CL-NET, CL-LINK 12 4 (I7, I8, I11, I12) no no yes yes 24 V DC CL-LD...17DC2 Rated frequency Input current on „1“ signal 0 Hz 3.3 mA (at 24 V DC, I1-I6, I9, I10), 2.2 mA (at 24 V DC, I7, I8, I11, I12) debounce ON 20 ms debounce OFF typ. 0.1 ms (I1-I4), typ. 0.25 ms (I5-I12) Time delay from „1“ to „0“ Cable length (unshielded) Maximum cable length per input Frequency counter Incremental counter Rapid counter inputs Cable length (shielded) Input circuit - Analog inputs Number Electrical isolation Input type Signal range Resolution Input impedance Accuracy of the actual value Conversion time analog/digital Input current Cable length (shielded) LCD-Display (if existing) 24 V DC U e on „0“ signal < 5 V DC (I1-I6, I9, I10), < 8 V DC (I7, I8, I11, I12) 0-40 V AC (sinusoidal) U e on „1“ signal > 15 V DC (I1-I6, I9, I10), > 8 V DC (I7, I8, I11, I12) Time delay from „0“ to „1“ CL-LDR.16AC2 115/230 V debounce ON 20 ms debounce OFF typ. 0.1 ms (I1-I4), typ. 0.4 ms (I5, I6, I9, I10), typ. 0.2 ms (I7, I8, I11, I12) 100 m number 4 (I1, I2, I3, I4) counting frequency < 3 kHz pulse shape square-wave pulse / pause ratio 1:1 number 2 (I1 + I2, I3 + I4) counting frequency < 3 kHz pulse shape square-wave signal offset 90° pulse / pause ratio 1:1 number 4 (I1, I2, I3, I4) counting frequency < 3 kHz pulse shape square-wave pulse / pause ratio 1:1 < 20 m to voltage supply to digital inputs to outputs to PC interface, memory modul, CL-NET, CL-LINK 4 (I7, I8, I11, I12) no no yes yes DC voltage 0-10 V DC analog 0.01 V digital 0.01 V; 10 Bit (value 0-1023) 11.2 kq two CL-LD... ± 3 % devices within one device ± 2 % each cycle < 1 mA < 30 m 79-264 V AC (sinusoidal) 50-60 Hz 12x0.2 mA (at 115 V AC, 60 Hz, I1-I12), 12x0.5 mA (at 230 V AC, 50 Hz, I1-I12) 10 ms (at 50 Hz), 100 ms (at 60 Hz) 10 ms (at 50 Hz), 100 ms (at 60 Hz) 10 ms (at 50 Hz), 100 ms (at 60 Hz) 10 ms (at 50 Hz), 100 ms (at 60 Hz) typ. 60 m - 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/20 6 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type Output circuit - Analog outputs Number Electrical separation CL-LD...16DC2 from voltage supply from the digital inputs from the digital outputs from PC interface, memory module, CL-NET, CL-LINK Output type Signal range Max. output current Burden resistance Overload and short-circuit protection Resolution analog digital Setting time Accuracy 6 -25...+55 °C 25 °C Conversion time General data Dimensions (W x H x D) Weight Mounting Mounting position Electrical connection Wire size Electrical connection - Data cable Wire size CL-LD...17DC2 CL-LDR.16AC2 - 1 no no yes yes - - DC voltage 0-10 V DC 0.01 A 1 kq yes 0.01 V DC 10 Bit, (value: 0-1023) 100 ms 2% 1% each CPU cycle - CL-LDR: 89 x 90 x 44 mm (3.5 x 3.54 x 1.73 inch) 89 x 90 x 44 mm CL-LDT (build-in): 89 x 90 x 25 mm (3.5 x 3.54 x 0.98 (3.5 x 3.54 x 1.73 inch) inch) CL-LDR: 0.15 kg (0.33 lb) / CL-LDT: 014 kg (0.31 lb) 0.15 kg (0.33 lb) snap-on power supply unit horizontal / vertical fine-strand with wire end ferrule 0.2 mm 2 / 2.5 mm 2 (24-12 AWG) rigid 0.2 mm 2 / 4 mm 2 (24-12 AWG) fine-strand with wire end ferrule 0.08 mm 2 / 1.5 mm 2 (28-12 AWG) rigid 0.08 mm 2 / 2.5 mm 2 (28-12 AWG) Environmental data Ambient temperature range Condensation Humidity, no condensation (IEC/EN 60068-2-30) Atmospheric pressure (operation) Degree of protection (IEC/EN 60529) Vibration (IEC/EN 60068-2-6) Shock (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27) Drop (IEC/EN 60068-2-31) height of fall Free fall, packaged (IEC/EN 60068-2-32) Insulation data Pollution degree Rating of air and creepage distances Isolation resistance Standards Standards and directives Electromagnetic compatibility electrostatic discharge (ESD) electromag. field (HF radiation res.) fast transients (Burst) powerful impulses (Surge) HF line emission Interference suppression (EN 55011, EN 55022) operation -25...+55 °C (cold acc. to IEC 60068-2-1, heat acc. to IEC 60068-2-2) storage -40...+70 °C avoid condensation with suitable methods 5-95 % 795-1080 hPa IP20 10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant acceleration 2 g) 18 Shocks 50 mm 1m 2 EN 50178, UL 508, CSA C22.2, No. 142 EN 50178 EN 61000-6-1/-2/-3/-4, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 Level 3 (air discharge 8 kV, contact discharge 6 kV) 10 V/m Level 3 (supply cable 2 kV, signal cable 2 kV) 2 kV (supply cable symmetrical), Level 2 (0.5 kV supply cable symmetrical) IEC/EN 61000-4-6 10 V class B 6/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type Output circuit - Relay outputs Number Outputs in groups of Parallel switching of outputs to increase capacity Fusing of the output relay Electrical isolation Mechanical lifetime Rung CL-LDR... 4 not permissible circuit-breaker B16 or fuse 8 A (slow-acting) from voltage supply yes from the inputs yes from PC interface, memory module, CL-NET, yes CL-LINK protective separation 300 V AC Basic isolation 600 V AC 10x10 6 switching cycles conventional thermal current (10 A UL) 8 A recommended load 12 V AC/DC > 500 mA short-circuit proof cos j = 1; 16 A characteristic B16 at 600 A short-circuit proof cos j = 0.5 up to 0.7; 16 A characteristic B16 at 900 A Rated impulse withstand voltage U imp contact-coil 6 kV 6 Rated operational voltage U e 250 V AC Rated insulation voltage U i Protective separation (EN 50178) Making capacity Breaking capacity Incandesent lamp load Fluorescent lamp load Switching frequency UL/CSA Continuous current at 240 V Continuous current at 24 V AC DC 250 V AC between coil and contact between two contacts AC-15, 250 V AC, 3 A (600 ops./h) DC13, L/R m 150 ms, 24 V DC, 1 A (500 ops./h) AC-15, 250 V AC, 3 A (600 ops./h) DC13, L/R m 150 ms, 24 V DC, 1 A (500 ops/h) 1000 W at 230/240 V AC 500 W at 115/120 V AC 10 x 58 W at 230/240 V AC with electrical control gear 10 x 58 W at 230/240 V AC uncompensated 1 x 58 W at 230/240 V AC conventional compensated mechanical operations switching frequency resistive load / lamp load inductive load Utilization category (Control Circuit Rating Codes) max. rated operational voltage max. continuous thermal current cos j = 1 at B 300 max. making / breaking apparent power (Make/Break) cos j ≠ 1 at B 300 Utilization category (Control Circuit Rating Codes) max. rated operational voltage max. continuous thermal current at R 300 max. making / breaking apparent power (Make/Break) at R 300 300 V AC 300V AC 300.000 switching cycles 200.000 switching cycles 300.000 switching cycles 200.000 switching cycles 25.000 switching cycles 25.000 switching cycles 25.000 switching cycles 25.000 switching cycles 25.000 switching cycles 10x10 6 10 Hz 2 Hz 0.5 Hz 10 A AC 8 A DC B 300 Light Pilot Duty 300 V AC 5A 3600/360 VA R 300 Light Pilot Duty 300 V DC 1A 28/28 VA 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/22 Logic relays Technical data Data at Ta = 25 °C and rated values, if nothing else indicated. Type CL-LDT... Output circuit - Transistor outputs Number Rated operational voltage U e 4 24 V DC Operational voltage range Residual ripple Supply current on „0“ signal on „1“ signal Reverse voltage protection Electrical isolation 6 from voltage supply from the inputs from PC interface, memory module, CL-NET, CL-LINK 20.4-28.8 V DC typ. 18 mA / max. 32 mA typ. 24 mA / max. 44 mA yes (Attention: If supply voltage is reversed, applying voltage at the outputs, causes a short circuit.) yes yes yes Rated operational current I e on„1“ signal DC max. 0.5 A Lamp load without R v 5 W (Q1-Q4) Residual current on „0“ signal per channel Max. output voltage < 0.1 mA on „0“ signal at external load < 10 Mq 2.5 V on „1“ signal at I e = 0.5 A U = U e - 1 V Short-circuit protection Short-circuit tripping current for R a m 10 mq Total short-circuit current Peak short-circuit current Thermal tripping Max. switching frequency with constant resistive load R L < 100 kq (depending on active channels and their load) Parallel connection of outputs with resistive load, inductive load with external suppressor, combination within one group number of outputs max. total current Indication of operational states of the outputs Inductive load1) without external suppressor T0.95 = 1 ms, R = 48 q, L = 16 mH DC13, T0.95 = 72 ms, R = 48 q, L = 1.15 H T0.95 = 15 ms, R = 48 q, L = 0.24 H Inductive load1) with external suppressor 1) utilization factor duty time max. switching frequency f = 0,5 Hz (max. duty time = 50 %) utilization factor duty time max. switching frequency f = 0,5 Hz (max. duty time = 50 %) utilization factor duty time max. switching frequency f = 0,5 Hz (max. duty time = 50 %) thermal (Q1-Q4), (analysis results from diagnosis input I16) 0.7 A m I e m 2 A per output 8A 16 A yes 40.000 switching cycles/h group 1: Q1-Q4 max. 4 2 A (Attention! Outputs must be actuated simultaneously and for the same length of time.) LCD-Display (if existing) 0.25 g 100 % 1500 switching cycles 0.25 g 100 % 1500 switching cycles 0.25 g 100 % 1500 switching cycles demand factor 1 g duty time 100 % max. switching frequency max. duty time depends on suppressor For inductive loading, without external suppression of the transistor outputs, the following applies: T0.95 = time in ms, until 95 % of the steady-state current is achieved. T0.95 3 × T0.65 = 3 × L/R. Data transfer rate in the CL-NET network: bus lengths of 40 m and over only attainable with cables with additional cross-section and connection adapter. 6/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010 Logic relays Dimensional drawings Dimensional drawings dimensions in mm CL-LSR, CL-LST 10.75 CL-LMR, CL-LMT 75 16.25 50 CL-LER.2O 7.5 16.25 56.5 58 47.5 56.5 58 45 110 90 M4 102 45 90 110 4.5 107.5 2CDC 312 013 F0b06 47.5 71.5 2CDC 312 012 F0b06 4.5 M4 35.75 102 45 2CDC 312 011 F0b06 90 102 110 M4 4.5 7.5 47.5 56.5 35.5 58 6 CL-LDC.S.. CL-LDD.K + CL-LDC.L.. + (CL-LDR or CL-LDT) 58 75 28.25 30 20 28.25 62 86.5 13.7 2CDC 312 018 F0b06 86.5 29.3 36.2 65.5 2CDC 312 015 F0b06 90 30 86.5 32 86.5 22.3 17 CL-LDD 107.5 88.2 20 43.2 33.7 88.1 19 25 2CDC 312 014 F0b06 2CDC 312 016 F0b06 90 CL-LDR, CL-LDT 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/24 Index Alphanumerical Type 7 Page Type Page Type Page Type Page Numbers A CC-E RTD/I.................................. 4/9 CC-E/TC.................................... 4/10 CL-LEC.CI000.............................. 6/7 CC-E RTD/I.................................. 4/9 CC-U/I....................................... 4/21 CL-LER.18AC2............................. 6/7 ADP.01.. ..................................... 1/40 CC-E RTD/I.................................. 4/9 CC-U/I....................................... 4/21 CL-LER.18DC2............................ 6/7 ADP.01.. ..................................... 1/40 CC-E RTD/I.................................. 4/9 CC-U/RTD................................. 4/21 CL-LER.2O.................................. 6/7 ADP.01.. ................................... 2/130 CC-E RTD/I.................................. 4/9 CC-U/RTD................................. 4/21 CL-LET.20DC2............................. 6/7 ADP.01.. ..................................... 4/22 CC-E RTD/I.................................. 4/9 CC-U/RTDR............................... 4/21 CL-LMR.C18AC1......................... 6/7 ADP.02.. ................................... 2/130 CC-E RTD/I.................................. 4/9 CC-U/RTDR............................... 4/21 CL-LMR.C18AC2......................... 6/7 B CC-E RTD/I.................................. 4/9 CC-U/STD.................................. 4/21 CL-LMR.C18DC1......................... 6/7 BADH V0................................... 5/47 CC-E RTD/I.................................. 4/9 CC-U/STD.................................. 4/21 CL-LMR.C18DC2......................... 6/7 BADL V0.................................... 5/47 CC-E RTD/I.................................. 4/9 CC-U/STDR............................... 4/21 CL-LMR.CX18AC1....................... 6/7 BAM2 V0................................... 5/47 CC-E RTD/I.................................. 4/9 CC-U/STDR............................... 4/21 CL-LMR.CX18AC2....................... 6/7 BJ 612-10.. ................................ 5/36 CC-E RTD/I.................................. 4/9 CC-U/TC.................................... 4/21 CL-LMR.CX18DC1....................... 6/7 BJ 612-10.. ................................ 5/47 CC-E RTD/I.................................. 4/9 CC-U/TC.................................... 4/21 CL-LMR.CX18DC2....................... 6/7 BJ 612-20.. ................................ 5/36 CC-E RTD/I.................................. 4/9 CC-U/TCR................................. 4/21 CL-LMT.C20DC2.......................... 6/7 BJ 612-20.. ................................ 5/47 CC-E RTD/V. . ............................... 4/9 CC-U/TCR................................. 4/21 CL-LMT.CX20DC2........................ 6/7 C CC-E RTD/V. . ............................... 4/9 CC-U/V...................................... 4/21 CL-LSR.12AC2............................ 6/6 C512-24.................................. 2/104 CC-E RTD/V. . ............................... 4/9 CC-U/V...................................... 4/21 CL-LSR.12DC2............................ 6/6 C512-D. . .................................. 2/104 CC-E RTD/V. . ............................... 4/9 CL-LAD.FD001............................. 6/9 CL-LSR.C12AC1.......................... 6/6 C512-E.................................... 2/104 CC-E RTD/V. . ............................... 4/9 CL-LAD.FD002............................. 6/9 CL-LSR.C12AC2.......................... 6/6 C512-W................................... 2/104 CC-E RTD/V. . ............................... 4/9 CL-LAD.FD011............................. 6/9 CL-LSR.C12DC1.......................... 6/6 C513-D. . .................................. 2/104 CC-E RTD/V. . ............................... 4/9 CL-LAD.MD004............................ 6/9 CL-LSR.C12DC2.......................... 6/6 C513-E.................................... 2/104 CC-E RTD/V. . ............................... 4/9 CL-LAD.TK001............................. 6/9 CL-LSR.CX12AC1........................ 6/6 C513-W................................... 2/104 CC-E TC/I.................................. 4/10 CL-LAD.TK002............................. 6/9 CL-LSR.CX12AC2........................ 6/6 CC-E I/I. . ...................................... 4/8 CC-E TC/I.................................. 4/10 CL-LAD.TK003............................. 6/9 CL-LSR.CX12DC1........................ 6/6 CC-E I/I. . ...................................... 4/8 CC-E TC/I.................................. 4/10 CL-LAD.TK004............................. 6/9 CL-LSR.CX12DC2........................ 6/6 CC-E I/I. . ...................................... 4/8 CC-E TC/I.................................. 4/10 CL-LAD.TK005............................. 6/9 CL-LST.C12DC2........................... 6/6 CC-E I/I. . ...................................... 4/8 CC-E TC/I.................................. 4/10 CL-LAD.TK006............................. 6/9 CL-LST.CX12DC2......................... 6/6 CC-E I/I. . ...................................... 4/8 CC-E TC/I.................................. 4/10 CL-LAD.TK007............................. 6/8 CM-AH-3................................. 2/116 CC-E I/I. . ...................................... 4/8 CC-E TC/I.................................. 4/10 CL-LAD.TK009............................. 6/9 CM-CT 100/1........................... 2/131 CC-E I/I. . ...................................... 4/8 CC-E TC/I.................................. 4/10 CL-LAD.TK011............................. 6/9 CM-CT 100/5........................... 2/131 CC-E I/I. . ...................................... 4/8 CC-E TC/V................................. 4/10 CL-LAS.FD001............................. 6/8 CM-CT 150/1........................... 2/131 CC-E I/I-1.................................... 4/8 CC-E TC/V................................. 4/10 CL-LAS.MD003............................ 6/8 CM-CT 150/5........................... 2/131 CC-E I/I-2.................................... 4/8 CC-E TC/V................................. 4/10 CL-LAS.PS002............................. 6/8 CM-CT 200/1........................... 2/131 CC-E I/V...................................... 4/8 CC-E TC/V................................. 4/10 CL-LAS.TK001............................. 6/8 CM-CT 200/5........................... 2/131 CC-E I/V...................................... 4/8 CC-E V/I...................................... 4/8 CL-LAS.TK002............................. 6/8 CM-CT 300/1........................... 2/131 CC-E IAC/I................................. 4/11 CC-E V/I...................................... 4/8 CL-LAS.TK011............................. 6/8 CM-CT 300/5........................... 2/131 CC-E IAC/I................................. 4/11 CC-E V/I...................................... 4/8 CL-LDC.LAC2.............................. 6/9 CM-CT 400/1........................... 2/131 CC-E IAC/I................................. 4/11 CC-E V/I...................................... 4/8 CL-LDC.LDC2.............................. 6/9 CM-CT 400/5........................... 2/131 CC-E IAC/I................................. 4/11 CC-E V/V..................................... 4/8 CL-LDC.LNAC2............................ 6/9 CM-CT 50/1............................. 2/131 CC-E IAC/ILPO.. ......................... 4/11 CC-E V/V..................................... 4/8 CL-LDC.LNDC2............................ 6/9 CM-CT 50/5............................. 2/131 CC-E IAC/V................................ 4/11 CC-E V/V..................................... 4/8 CL-LDC.SAC2.............................. 6/6 CM-CT 500/1........................... 2/131 CC-E IAC/V................................ 4/11 CC-E V/V..................................... 4/8 CL-LDC.SDC2.............................. 6/6 CM-CT 500/5........................... 2/131 CC-E IDC/I................................. 4/11 CC-E V/V..................................... 4/8 CL-LDD.K.................................... 6/6 CM-CT 600/1........................... 2/131 CC-E IDC/I................................. 4/11 CC-E V/V..................................... 4/8 CL-LDD.K.................................... 6/9 CM-CT 600/5........................... 2/131 CC-E IDC/I................................. 4/11 CC-E/I....................................... 4/11 CL-LDD.XK.................................. 6/6 CM-CT 75/1............................. 2/131 CC-E IDC/I................................. 4/11 CC-E/I....................................... 4/11 CL-LDD.XK.................................. 6/9 CM-CT 75/5............................. 2/131 CC-E IDC/V.. .............................. 4/11 CC-E/RTD. . .................................. 4/9 CL-LDR.16AC2............................ 6/9 CM-CT A.................................. 2/131 CC-E IDC/V.. .............................. 4/11 CC-E/RTD. . .................................. 4/9 CL-LDR.16DC2............................ 6/9 CM-EFS.2P................................ 2/16 CC-E RTD/I.................................. 4/9 CC-E/STD.................................... 4/8 CL-LDR.17DC2............................ 6/9 CM-EFS.2S................................ 2/16 CC-E RTD/I.................................. 4/9 CC-E/STD.................................... 4/8 CL-LDT.16DC2............................. 6/9 CM-ENE MAX........................... 2/115 CC-E/TC.................................... 4/10 CL-LDT.17DC2............................. 6/9 CM-ENE MAX........................... 2/115 2/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Index Alphanumerical Type Page Type Page Type Page Type Page CM-ENE MAX.. ......................... 2/115 CM-LWN.................................... 2/76 CM-PAS.41S.............................. 2/33 CM-TCS.21P ........................... 2/104 CM-ENE MIN.. .......................... 2/115 CM-LWN.................................... 2/76 CM-PBE..................................... 2/33 CM-TCS.21S ........................... 2/104 CM-ENE MIN.. .......................... 2/115 CM-LWN.................................... 2/76 CM-PBE..................................... 2/33 CM-TCS.22P ........................... 2/104 CM-ENE MIN.. .......................... 2/115 CM-LWN.................................... 2/76 CM-PFE..................................... 2/33 CM-TCS.22S ........................... 2/104 CM-ENN.................................. 2/115 CM-LWN.................................... 2/76 CM-PFS.P.................................. 2/33 CM-TCS.23P ........................... 2/104 CM-ENN.................................. 2/115 CM-MPN.52P. . ........................... 2/34 CM-PFS.S ................................. 2/33 CM-TCS.23S ........................... 2/104 CM-ENN.................................. 2/115 CM-MPN.52S. . ........................... 2/34 CM-PSS.31P.............................. 2/33 CM-UFD.M22............................. 2/54 CM-ENN.................................. 2/115 CM-MPN.62P. . ........................... 2/34 CM-PSS.31S.............................. 2/33 CM-UFD.M31............................. 2/54 CM-ENS.................................. 2/115 CM-MPN.62S. . ........................... 2/34 CM-PSS.41P.............................. 2/33 CM-UFD.M33............................. 2/54 CM-ENS.................................. 2/115 CM-MPN.72P. . ........................... 2/34 CM-PSS.41S.............................. 2/33 COV.01...................................... 1/40 CM-ENS.................................. 2/115 CM-MPN.72S. . ........................... 2/34 CM-PVE..................................... 2/33 COV.01.................................... 2/130 CM-ENS.................................. 2/115 CM-MPS.11P............................. 2/34 CM-PVE..................................... 2/33 COV.01...................................... 4/22 CM-ENS UP/DOWN.. ................ 2/115 CM-MPS.11S............................. 2/34 CM-PVS.31P.............................. 2/33 COV.02.................................... 2/130 CM-ENS UP/DOWN.. ................ 2/115 CM-MPS.21P............................. 2/34 CM-PVS.31S.............................. 2/33 COV.11...................................... 1/40 CM-ENS UP/DOWN.. ................ 2/115 CM-MPS.21S............................. 2/34 CM-PVS.41P.............................. 2/33 COV.11.................................... 2/130 CM-ESS.1P.. .............................. 2/16 CM-MPS.23P............................. 2/34 CM-PVS.41S.............................. 2/33 COV.12.................................... 2/130 CM-ESS.1P.. .............................. 2/16 CM-MPS.23S............................. 2/34 CM-PVS.81P.............................. 2/33 CP-A CM................................... 3/51 CM-ESS.1P.. .............................. 2/16 CM-MPS.31P............................. 2/34 CM-PVS.81S.............................. 2/33 CP-A RU.................................... 3/51 CM-ESS.1S.. .............................. 2/16 CM-MPS.31S............................. 2/34 CM-SE-1000............................ 2/116 CP-ASI/2.8................................. 3/60 CM-ESS.1S.. .............................. 2/16 CM-MPS.41P............................. 2/34 CM-SE-300.............................. 2/116 CP-ASI/4.0................................. 3/60 CM-ESS.1S.. .............................. 2/16 CM-MPS.41S............................. 2/34 CM-SE-600.............................. 2/116 CP-ASI/4.0 DC/DC..................... 3/60 CM-ESS.2P.. .............................. 2/16 CM-MPS.43P............................. 2/34 CM-SFS.21P.............................. 2/15 CP-ASI/8.0................................. 3/60 CM-ESS.2P.. .............................. 2/16 CM-MPS.43S............................. 2/34 CM-SFS.21S.............................. 2/15 CP-B 24/10.0............................. 3/68 CM-ESS.2P.. .............................. 2/16 CM-MSE.................................... 2/90 CM-SFS.22S.............................. 2/15 CP-B 24/20.0............................. 3/68 CM-ESS.2S.. .............................. 2/16 CM-MSE.................................... 2/90 CM-SRS.11P.............................. 2/15 CP-B 24/3.0............................... 3/68 CM-ESS.2S.. .............................. 2/16 CM-MSE.................................... 2/90 CM-SRS.11P.............................. 2/15 CP-B EXT.2................................ 3/68 CM-ESS.2S.. .............................. 2/16 CM-MSS.11P............................. 2/90 CM-SRS.11P.............................. 2/15 CP-C 24/10.0............................. 3/45 CM-ESS.MP.. ............................. 2/16 CM-MSS.11S............................. 2/90 CM-SRS.11S.............................. 2/15 CP-C 24/20.0............................. 3/45 CM-ESS.MS.. ............................. 2/16 CM-MSS.12P............................. 2/90 CM-SRS.11S.............................. 2/15 CP-C 24/5.0............................... 3/45 CM-GM-1.. ............................... 2/116 CM-MSS.12S............................. 2/90 CM-SRS.11S.............................. 2/15 CP-C MM................................... 3/45 CM-HE. . ................................... 2/116 CM-MSS.13P............................. 2/90 CM-SRS.12S.............................. 2/15 CP-D 12/0.83............................. 3/10 CM-IVN.P.. ................................. 2/66 CM-MSS.13S............................. 2/90 CM-SRS.12S.............................. 2/15 CP-D 12/2.1............................... 3/10 CM-IVN.S.. ................................. 2/66 CM-MSS.21P............................. 2/90 CM-SRS.12S.............................. 2/15 CP-D 24/0.42............................. 3/10 CM-IWN.1P.. .............................. 2/66 CM-MSS.21S............................. 2/90 CM-SRS.21P.............................. 2/15 CP-D 24/0.42............................... 6/8 CM-IWN.1S.. .............................. 2/66 CM-MSS.22P............................. 2/90 CM-SRS.21P.............................. 2/15 CP-D 24/1.3............................... 3/10 CM-IWN.4P.. .............................. 2/66 CM-MSS.22S............................. 2/90 CM-SRS.21P.............................. 2/15 CP-D 24/1.3................................. 6/8 CM-IWN.4S.. .............................. 2/66 CM-MSS.23P............................. 2/90 CM-SRS.21S.............................. 2/15 CP-D 24/2.5............................... 3/10 CM-IWN.5P.. .............................. 2/66 CM-MSS.23S............................. 2/90 CM-SRS.21S.............................. 2/15 CP-D 24/4.2............................... 3/10 CM-IWN.5S.. .............................. 2/66 CM-MSS.31P............................. 2/90 CM-SRS.21S.............................. 2/15 CP-D RU.................................... 3/51 CM-IWN.6P.. .............................. 2/66 CM-MSS.31S............................. 2/90 CM-SRS.22S.............................. 2/15 CP-E 12/10.0............................. 3/20 CM-IWN.6S.. .............................. 2/66 CM-MSS.32P............................. 2/90 CM-SRS.22S.............................. 2/15 CP-E 12/2.5............................... 3/20 CM-IWS.1P................................ 2/66 CM-MSS.32S............................. 2/90 CM-SRS.22S.............................. 2/15 CP-E 24/0.75............................. 3/20 CM-IWS.1S................................ 2/66 CM-MSS.33P............................. 2/90 CM-SRS.M1P............................. 2/15 CP-E 24/1.25............................. 3/20 CM-IWS.2P................................ 2/66 CM-MSS.33S............................. 2/90 CM-SRS.M1S............................. 2/15 CP-E 24/10.0............................. 3/20 CM-IWS.2S................................ 2/66 CM-MSS.41P............................. 2/90 CM-SRS.M2S............................. 2/15 CP-E 24/2.5............................... 3/20 CM-KH-3................................. 2/116 CM-MSS.41S............................. 2/90 CM-TCS.11P ........................... 2/104 CP-E 24/20.0............................. 3/20 CM-LWN.................................... 2/76 CM-MSS.51P............................. 2/90 CM-TCS.11S ........................... 2/104 CP-E 24/5.0............................... 3/20 CM-LWN.................................... 2/76 CM-MSS.51S............................. 2/90 CM-TCS.12P ........................... 2/104 CP-E 48/0.62............................. 3/20 CM-LWN.................................... 2/76 CM-PAS.31P.............................. 2/33 CM-TCS.12S ........................... 2/104 CP-E 48/1.25............................. 3/20 CM-LWN.................................... 2/76 CM-PAS.31S.............................. 2/33 CM-TCS.13P ........................... 2/104 CP-E 48/10.0............................. 3/20 CM-LWN.................................... 2/76 CM-PAS.41P.............................. 2/33 CM-TCS.13S ........................... 2/104 CP-E 48/5.0............................... 3/20 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/2 7 Index Alphanumerical Type 7 Page Type Page Type Page Type Page CP-E 5/3.0.. ............................... 3/20 CR-M048DC4LG........................ 5/11 CR-M230AC4L........................... 5/11 CR-P048DC1............................... 5/9 CP-RUD. . ................................... 3/51 CR-M060AC3. . ........................... 5/10 CR-M230AC4LG........................ 5/11 CR-P048DC2............................... 5/9 CP-S 24/10.0............................. 3/45 CR-M060DC2............................ 5/10 CR-M2LC................................... 5/11 CR-P110AC1............................... 5/9 CP-S 24/20.0............................. 3/45 CR-M060DC2L. . ......................... 5/11 CR-M2LS................................... 5/11 CR-P110AC2............................... 5/9 CP-S 24/5.0.. ............................. 3/45 CR-M060DC3............................ 5/10 CR-M2SF................................... 5/11 CR-P110AC2G............................. 5/9 CP-T 24/10.0............................. 3/34 CR-M060DC3L. . ......................... 5/11 CR-M2SS................................... 5/11 CR-P110DC1............................... 5/9 CP-T 24/20.0............................. 3/34 CR-M060DC4............................ 5/10 CR-M3LS................................... 5/11 CR-P110DC2............................... 5/9 CP-T 24/40.0............................. 3/34 CR-M060DC4L. . ......................... 5/11 CR-M3SS................................... 5/11 CR-P120AC1............................... 5/9 CP-T 24/5.0............................... 3/34 CR-M060DC4LG........................ 5/11 CR-M4LC................................... 5/11 CR-P120AC2............................... 5/9 CP-T 48/10.0............................. 3/34 CR-M110AC2. . ........................... 5/10 CR-M4LS................................... 5/11 CR-P230AC1............................... 5/9 CP-T 48/20.0............................. 3/34 CR-M110AC2L. . ......................... 5/11 CR-M4SF................................... 5/11 CR-P230AC2............................... 5/9 CP-T 48/5.0............................... 3/34 CR-M110AC3. . ........................... 5/10 CR-M4SS................................... 5/11 CR-P230AC2G............................. 5/9 CR-M012DC2............................ 5/10 CR-M110AC3L. . ......................... 5/11 CR-MH...................................... 5/11 CR-PH......................................... 5/9 CR-M012DC2L.. ......................... 5/11 CR-M110AC4. . ........................... 5/10 CR-MH1.................................... 5/11 CR-PJ.......................................... 5/9 CR-M012DC3............................ 5/10 CR-M110AC4G.......................... 5/11 CR-MJ....................................... 5/11 CR-PLC....................................... 5/9 CR-M012DC3L.. ......................... 5/11 CR-M110AC4L. . ......................... 5/11 CR-MM...................................... 5/11 CR-PLS....................................... 5/9 CR-M012DC4............................ 5/10 CR-M110AC4LG........................ 5/11 CR-P/M 22................................. 5/12 CR-PLSx...................................... 5/9 CR-M012DC4L.. ......................... 5/11 CR-M110DC2............................ 5/10 CR-P/M 42................................. 5/12 CR-PM......................................... 5/9 CR-M012DC4LDG.. .................... 5/11 CR-M110DC2L. . ......................... 5/11 CR-P/M 42B.............................. 5/12 CR-PSS....................................... 5/9 CR-M012DC4LG........................ 5/11 CR-M110DC3............................ 5/10 CR-P/M 42BV............................ 5/12 CR-S005VDC1R........................... 5/8 CR-M024AC2.. ........................... 5/10 CR-M110DC3L. . ......................... 5/11 CR-P/M 42C.............................. 5/12 CR-S005VDC1RG........................ 5/8 CR-M024AC2L.. ......................... 5/11 CR-M110DC4............................ 5/10 CR-P/M 42CV............................ 5/12 CR-S006/024VDC1SS.................. 5/8 CR-M024AC3.. ........................... 5/10 CR-M110DC4L. . ......................... 5/11 CR-P/M 42V............................... 5/12 CR-S006/024VDC1SZ.................. 5/8 CR-M024AC3L.. ......................... 5/11 CR-M110DC4LG........................ 5/11 CR-P/M 52B.............................. 5/12 CR-S012/024VADC1SS................ 5/8 CR-M024AC4.. ........................... 5/10 CR-M120AC2. . ........................... 5/10 CR-P/M 52C.............................. 5/12 CR-S012/024VADC1SZ................ 5/8 CR-M024AC4G.......................... 5/11 CR-M120AC2L. . ......................... 5/11 CR-P/M 52D.............................. 5/12 CR-S012VDC1R........................... 5/8 CR-M024AC4L.. ......................... 5/11 CR-M120AC3. . ........................... 5/10 CR-P/M 62................................. 5/12 CR-S012VDC1RG........................ 5/8 CR-M024AC4LG........................ 5/11 CR-M120AC3L. . ......................... 5/11 CR-P/M 62C.............................. 5/12 CR-S024VADC1CRGS.................. 5/8 CR-M024DC2............................ 5/10 CR-M120AC4. . ........................... 5/10 CR-P/M 62CV............................ 5/12 CR-S024VADC1CRGZ.................. 5/8 CR-M024DC2L.. ......................... 5/11 CR-M120AC4L. . ......................... 5/11 CR-P/M 62D.............................. 5/12 CR-S024VADC1CRS.................... 5/8 CR-M024DC3............................ 5/10 CR-M120AC4LG........................ 5/11 CR-P/M 62DV............................ 5/12 CR-S024VADC1CRZ..................... 5/8 CR-M024DC3L.. ......................... 5/11 CR-M125DC2............................ 5/10 CR-P/M 62E............................... 5/12 CR-S024VDC1R........................... 5/8 CR-M024DC4............................ 5/10 CR-M125DC2L. . ......................... 5/11 CR-P/M 62EV............................. 5/12 CR-S024VDC1RG........................ 5/8 CR-M024DC4G.......................... 5/11 CR-M125DC3............................ 5/10 CR-P/M 62V............................... 5/12 CR-S048/060VADC1SS................ 5/8 CR-M024DC4L.. ......................... 5/11 CR-M125DC3L. . ......................... 5/11 CR-P/M 72................................. 5/12 CR-S048/060VADC1SZ................ 5/8 CR-M024DC4LD........................ 5/11 CR-M125DC4............................ 5/10 CR-P/M 72A.............................. 5/12 CR-S048VDC1R........................... 5/8 CR-M024DC4LDG.. .................... 5/11 CR-M125DC4L. . ......................... 5/11 CR-P/M 82................................. 5/12 CR-S048VDC1RG........................ 5/8 CR-M024DC4LG........................ 5/11 CR-M125DC4LG........................ 5/11 CR-P/M 92................................. 5/12 CR-S060VDC1R........................... 5/8 CR-M048AC2.. ........................... 5/10 CR-M220DC2............................ 5/10 CR-P/M 92C.............................. 5/12 CR-S060VDC1RG........................ 5/8 CR-M048AC2L.. ......................... 5/11 CR-M220DC2L. . ......................... 5/11 CR-P/M 92CV............................ 5/12 CR-S110/125VADC1SS................ 5/8 CR-M048AC3.. ........................... 5/10 CR-M220DC3............................ 5/10 CR-P/M 92V............................... 5/12 CR-S110/125VADC1SZ................ 5/8 CR-M048AC3L.. ......................... 5/11 CR-M220DC3L. . ......................... 5/11 CR-P012DC1............................... 5/9 CR-S110VADC1CRGS.................. 5/8 CR-M048AC4.. ........................... 5/10 CR-M220DC4............................ 5/10 CR-P012DC2............................... 5/9 CR-S110VADC1CRGZ.................. 5/8 CR-M048AC4L.. ......................... 5/11 CR-M220DC4L. . ......................... 5/11 CR-P024AC1............................... 5/9 CR-S110VADC1CRS.................... 5/8 CR-M048AC4LG........................ 5/11 CR-M220DC4LG........................ 5/11 CR-P024AC2............................... 5/9 CR-S110VADC1CRZ..................... 5/8 CR-M048DC2............................ 5/10 CR-M230AC2. . ........................... 5/10 CR-P024AC2G............................. 5/9 CR-S220/240VADC1SS................ 5/8 CR-M048DC2L.. ......................... 5/11 CR-M230AC2L. . ......................... 5/11 CR-P024DC1............................... 5/9 CR-S220/240VADC1SZ................ 5/8 CR-M048DC3............................ 5/10 CR-M230AC3. . ........................... 5/10 CR-P024DC2............................... 5/9 CR-S230VADC1CRGS.................. 5/8 CR-M048DC3L.. ......................... 5/11 CR-M230AC3L. . ......................... 5/11 CR-P024DC2............................... 5/9 CR-S230VADC1CRGZ.................. 5/8 CR-M048DC4............................ 5/10 CR-M230AC4. . ........................... 5/10 CR-P048AC1............................... 5/9 CR-S230VADC1CRS.................... 5/8 CR-M048DC4L.. ......................... 5/11 CR-M230AC4G.......................... 5/11 CR-P048AC2............................... 5/9 CR-S230VADC1CRZ..................... 5/8 2/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Index Alphanumerical Type Page Type Page Type Page Type Page CR-SJB20-BLACK....................... 5/8 CR-U060AC3............................. 5/13 CT-ARE...................................... 1/20 CT-MVS.12S.............................. 1/37 CR-SJB20-BLUE.......................... 5/8 CR-U110AC2............................. 5/13 CT-ARE...................................... 1/20 CT-MVS.21P.............................. 1/37 CR-SJB20-RED.. .......................... 5/8 CR-U110AC2L........................... 5/13 CT-ARE...................................... 1/20 CT-MVS.21S.............................. 1/37 CR-SM. . ....................................... 5/8 CR-U110AC3............................. 5/13 CT-ARE...................................... 1/20 CT-MVS.22P.............................. 1/37 CR-SSEP..................................... 5/8 CR-U110AC3L........................... 5/13 CT-ARS.11P............................... 1/38 CT-MVS.22S.............................. 1/37 CR-U 21.................................... 5/14 CR-U110DC2............................. 5/13 CT-ARS.11S............................... 1/38 CT-MVS.23P.............................. 1/37 CR-U 41.................................... 5/14 CR-U110DC2L........................... 5/13 CT-ARS.21P............................... 1/38 CT-MVS.23S.............................. 1/37 CR-U 41B.................................. 5/14 CR-U110DC3............................. 5/13 CT-ARS.21S............................... 1/38 CT-MXS.22P.............................. 1/37 CR-U 41BV................................ 5/14 CR-U110DC3L........................... 5/13 CT-AWE..................................... 1/20 CT-SAD.22................................... 1/8 CR-U 41C.................................. 5/14 CR-U120AC2............................. 5/13 CT-AWE..................................... 1/20 CT-SDD.22................................... 1/8 CR-U 41CV................................ 5/14 CR-U120AC2L........................... 5/13 CT-AWE..................................... 1/20 CT-SDE...................................... 1/21 CR-U 41V.................................. 5/14 CR-U120AC3............................. 5/13 CT-AWE .................................... 1/21 CT-SDE...................................... 1/21 CR-U 51B.................................. 5/14 CR-U120AC3L........................... 5/13 CT-AWE .................................... 1/21 CT-SDE...................................... 1/21 CR-U 51C.................................. 5/14 CR-U125DC3............................. 5/13 CT-AWE .................................... 1/21 CT-SDS.22P............................... 1/38 CR-U 51D.................................. 5/14 CR-U220DC2............................. 5/13 CT-AWE .................................... 1/21 CT-SDS.22S............................... 1/38 CR-U 61.................................... 5/14 CR-U220DC2L........................... 5/13 CT-AWE .................................... 1/21 CT-SDS.23P............................... 1/38 CR-U 61C.................................. 5/14 CR-U220DC3............................. 5/13 CT-AWE .................................... 1/21 CT-SDS.23S............................... 1/38 CR-U 61CV................................ 5/14 CR-U220DC3L........................... 5/13 CT-AWE .................................... 1/21 CT-TGD.12................................... 1/8 CR-U 61D.................................. 5/14 CR-U230AC2............................. 5/13 CT-AWE .................................... 1/21 CT-TGD.22................................... 1/8 CR-U 61DV................................ 5/14 CR-U230AC2L........................... 5/13 CT-AWE .................................... 1/21 CT-VWD.12.................................. 1/8 CR-U 61E.................................. 5/14 CR-U230AC3............................. 5/13 CT-EBD.12................................... 1/8 CT-VWE..................................... 1/20 CR-U 61EV................................ 5/14 CR-U230AC3L........................... 5/13 CT-EBE...................................... 1/21 CT-VWE..................................... 1/20 CR-U 61V.................................. 5/14 CR-U2S..................................... 5/13 CT-EBE...................................... 1/21 CT-VWE..................................... 1/20 CR-U 71.................................... 5/14 CR-U2SM.................................. 5/13 CT-EKE...................................... 1/21 CT-VWE..................................... 1/20 CR-U 71A.................................. 5/14 CR-U3E..................................... 5/13 CT-EKE...................................... 1/21 CT-VWE..................................... 1/20 CR-U 81.................................... 5/14 CR-U3S..................................... 5/13 CT-EKE...................................... 1/21 CT-VWE..................................... 1/20 CR-U 91.................................... 5/14 CR-U3SM.................................. 5/13 CT-ERD.12................................... 1/8 CT-WBS.22P.............................. 1/37 CR-U 91C.................................. 5/14 CR-UH....................................... 5/13 CT-ERD.22................................... 1/8 CT-WBS.22S.............................. 1/37 CR-U 91CV................................ 5/14 CT- MXS.22S............................. 1/37 CT-ERE...................................... 1/20 CT-YDE...................................... 1/21 CR-U 91V.................................. 5/14 CT-AHD.12. . ................................. 1/8 CT-ERE...................................... 1/20 CT-YDE...................................... 1/21 CR-U T...................................... 5/14 CT-AHD.22. . ................................. 1/8 CT-ERE...................................... 1/20 CT-YDE...................................... 1/21 CR-U012DC2............................. 5/13 CT-AHE. . .................................... 1/20 CT-ERE...................................... 1/20 CT-YDE...................................... 1/21 CR-U012DC2L........................... 5/13 CT-AHE. . .................................... 1/20 CT-ERE...................................... 1/20 CT-YDE...................................... 1/21 CR-U012DC3............................. 5/13 CT-AHE. . .................................... 1/20 CT-ERE...................................... 1/20 CT-YDE...................................... 1/21 CR-U012DC3L........................... 5/13 CT-AHE. . .................................... 1/20 CT-ERE...................................... 1/20 E CR-U024AC2............................. 5/13 CT-AHE. . .................................... 1/20 CT-ERE...................................... 1/20 EPD24-TB-101-0.5A.................. 3/75 CR-U024AC2L........................... 5/13 CT-AHE. . .................................... 1/20 CT-ERS.12P............................... 1/38 EPD24-TB-101-10A................... 3/75 CR-U024AC3............................. 5/13 CT-AHE. . .................................... 1/20 CT-ERS.12S............................... 1/38 EPD24-TB-101-12A................... 3/75 CR-U024AC3L........................... 5/13 CT-AHE. . .................................... 1/20 CT-ERS.21P............................... 1/38 EPD24-TB-101-1A..................... 3/75 CR-U024DC2............................. 5/13 CT-AHE. . .................................... 1/20 CT-ERS.21S............................... 1/38 EPD24-TB-101-2A..................... 3/75 CR-U024DC2L........................... 5/13 CT-AHS.22P. . ............................. 1/38 CT-ERS.22P............................... 1/38 EPD24-TB-101-3A..................... 3/75 CR-U024DC3............................. 5/13 CT-AHS.22S. . ............................. 1/38 CT-ERS.22S............................... 1/38 EPD24-TB-101-4A..................... 3/75 CR-U024DC3L........................... 5/13 CT-AKE...................................... 1/21 CT-MBS.22P.............................. 1/37 EPD24-TB-101-6A..................... 3/75 CR-U048AC2............................. 5/13 CT-AKE...................................... 1/21 CT-MBS.22S.............................. 1/37 EPD24-TB-101-8A..................... 3/75 CR-U048AC2L........................... 5/13 CT-AKE...................................... 1/21 CT-MFD.12................................... 1/8 EPD-BB500............................... 3/75 CR-U048AC3............................. 5/13 CT-APS.12P............................... 1/38 CT-MFD.21................................... 1/8 EPD-SB21.................................. 3/75 CR-U048AC3L........................... 5/13 CT-APS.12S............................... 1/38 CT-MFE...................................... 1/20 F CR-U048DC2............................. 5/13 CT-APS.21P............................... 1/38 CT-MFS.21................................. 1/37 FC2........................................... 5/47 CR-U048DC2L........................... 5/13 CT-APS.21S............................... 1/38 CT-MFS.21P............................... 1/37 CR-U048DC3............................. 5/13 CT-APS.22P............................... 1/38 CT-MKE..................................... 1/21 CR-U048DC3L........................... 5/13 CT-APS.22S............................... 1/38 CT-MVS.12P.............................. 1/37 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/4 7 Index Alphanumerical Type 7 Page Type Page Type Page I OBOC 1000-48-60VAC/DC. . ....... 5/47 ILPH BdC /RS 422 - 485 (24 V DC OBOC 1000-5-12VDC................ 5/47 RB122A-48-60VAC/DC............... 5/36 power supply).. ........................... 4/37 OBOC 1500-24VAC/DC.............. 5/47 RBR101AR-24VAC/DC............... 5/35 ILPH RS 232 (24 V DC power supply). OBOC 5000-115VAC/DC............ 5/47 RBR111A-24VAC/DC.................. 5/35 4/37 OBOC 5000-230VAC/DC............ 5/47 RBR111AR-24VAC/DC............... 5/35 ILPH RS 232 / FO-S (24...42 V AC/ OBOC 5000-24VDC................... 5/47 RBR121-12VDC......................... 5/36 DC power supply)....................... 4/37 OBRIC 0100-115-230VAC/DC.... 5/47 RBR121-12VDC......................... 5/36 ILPH RS 232 / RS 232 (115-230 V AC OBRIC 0100-24VDC................... 5/47 RBR121-24VDC......................... 5/36 power supply).. ........................... 4/37 OBRIC 0100-48-60VAC/DC........ 5/47 RBR121-5VDC........................... 5/36 ILPH RS 232 / RS 232 (24-48 V DC OBRIC 0100-5-12VDC. . .............. 5/47 RBR121-5VDC........................... 5/35 power supply).. ........................... 4/37 OBROA 1000-115VAC/DC.......... 5/47 RBR121A-115VAC/DC................ 5/36 ILPH RS 232 / RS 422-485......... 4/37 OBROA 1000-230VAC/DC.......... 5/47 RBR121A-115VAC/DC................ 5/35 ILPH RS 232 / RS 422-485......... 4/37 OBROA 1000-24VDC................. 5/47 RBR121A-230VAC/DC................ 5/36 ILPH RS 232 / RS 422-485 (115-230 OBROA 1000-48-60VAC/DC....... 5/47 RBR121A-230VAC/DC................ 5/35 V AC power supply).................... 4/37 OBROA 2000-24VDC................. 5/47 RBR121A-24VAC/DC.................. 5/36 ILPH RS 232 / RS 422-485 (24-48 V OBROC 1000-115VAC/DC. . ........ 5/47 RBR121A-24VAC/DC.................. 5/35 DC power supply)....................... 4/37 OBROC 1000-230VAC/DC. . ........ 5/47 RBR121A-48-60VUC.................. 5/36 ILPH RS 232-RS 485 / Ethernet.. 4/37 OBROC 1000-24VDC................. 5/47 RBR121A-48-60VUC.................. 5/35 ILPH RS 422 - 485 / RS 422 - 485 OBROC 1000-48-60VAC/DC....... 5/47 RBR121A-60-230VUC................ 5/36 (24 V DC power supply).............. 4/37 OBROC 1000-5-12VDC.............. 5/47 RBR121AR-115VAC/DC............. 5/36 ILPH RS 485 / FO-S (24...42 V AC/ OBROC 1500-24VAC/DC. . .......... 5/47 RBR121AR-230VAC/DC............. 5/36 DC power supply)....................... 4/37 OBROC 5000-115VAC/DC. . ........ 5/47 RBR121-AU-12VDC................... 5/35 K OBROC 5000-230VAC/DC. . ........ 5/47 RBR121-AU-24VDC................... 5/35 KA1-8029.................................. 1/39 OBROC 5000-24VDC................. 5/47 RBR122A-115VAC/DC................ 5/36 KA1-8030.................................. 1/39 R RBR122A-230VAC/DC................ 5/36 M RB101AR-24VAC/DC.. ................ 5/35 RBR122A-24VAC/DC.................. 5/36 MA16-1060................................ 1/39 RB111A-115VAC/DC.................. 5/35 RBR122A-48-60VUC.................. 5/36 MAR.01..................................... 1/40 RB111A-230VAC/DC.................. 5/35 S MAR.01..................................... 1/40 RB111A-24VAC/DC. . .................. 5/35 SC 612...................................... 5/36 MAR.01................................... 2/130 RB111AR-24VAC/DC.. ................ 5/35 SC 612...................................... 5/47 MAR.01..................................... 4/22 RB121-12VDC........................... 5/36 SK 615 562-87........................... 1/39 MAR.02..................................... 1/40 RB121-12VDC........................... 5/36 SK 615 562-88........................... 1/39 MAR.02................................... 2/130 RB121-24VDC........................... 5/36 MAR.12..................................... 1/40 RB121-5VDC............................. 5/36 MAR.12................................... 2/130 RB121-5VDC............................. 5/35 MT-150B.................................... 1/39 RB121A-115VAC/DC.................. 5/36 MT-250B.................................... 1/39 RB121A-115VAC/DC.................. 5/35 MT-350B.................................... 1/39 RB121A-230VAC/DC.................. 5/36 O RB121A-230VAC/DC.................. 5/35 OBIC 0100-115-230VAC/DC.. ..... 5/47 RB121A-24VAC/DC. . .................. 5/36 OBIC 0100-24VDC..................... 5/47 RB121A-24VAC/DC. . .................. 5/35 OBIC 0100-48-60VAC/DC.......... 5/47 RB121A-48-60VAC/DC. . ............. 5/36 OBIC 0100-5-12VDC.................. 5/47 RB121A-48-60VAC/DC. . ............. 5/35 OBOA 1000-115VAC/DC............ 5/47 RB121A-60-230VUC.................. 5/36 OBOA 1000-230VAC/DC............ 5/47 RB121AR-115VAC/DC. . .............. 5/36 OBOA 1000-24VDC.. .................. 5/47 RB121AR-230VAC/DC. . .............. 5/36 OBOA 1000-48-60VAC/DC......... 5/47 RB121-AU-12VDC. . .................... 5/35 OBOA 2000-24VDC.. .................. 5/47 RB121-AU-24VDC. . .................... 5/35 OBOC 1000-115VAC/DC............ 5/47 RB122A-115VAC/DC.................. 5/36 OBOC 1000-230VAC/DC............ 5/47 RB122A-230VAC/DC.................. 5/36 RB122A-24VAC/DC.................... 5/36 OBOC 1000-24VDC................... 5/47 2/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Index Numerical Order code Type Page Order code Type Page Order code Type Page 1SAR 1SNA645046R0700. . . RB121AR-115VAC/DC................. 5/36 1SNA645558R1500. . . OBROC 5000-115VAC/DC........... 5/47 1SAR700100R0005. .. C512-24.................................... 2/104 1SNA645047R0000. . . OBIC 0100-5-12VDC................... 5/47 1SNA645559R1600. . . OBROC 5000-230VAC/DC........... 5/47 1SAR700100R0010. .. C512-W. .................................... 2/104 1SNA645049R1200. . . OBIC 0100-48-60VAC/DC............ 5/47 1SNA645561R0000. . . OBROA 1000-48-60VAC/DC........ 5/47 1SAR700110R0010. .. C513-W. .................................... 2/104 1SNA645050R1700. . . OBOC 1000-5-12VDC. . ................ 5/47 1SNA645562R0100. . . OBROA 1000-115VAC/DC........... 5/47 1SFA 1SNA645051R0400. . . OBOC 1000-24VDC..................... 5/47 1SNA645571R0000. . . RBR121-24VDC. . ......................... 5/36 1SFA611410R1506... MT-150B..................................... 1/39 1SNA645053R0600. . . OBOC 1000-48-60VAC/DC.......... 5/47 1SNA645572R0000. . . RBR121-AU-24VDC..................... 5/35 1SFA611410R2506... MT-250B..................................... 1/39 1SNA645054R0700. . . OBOC 1000-115VAC/DC.. ............ 5/47 1SNA645573R0000. . . RBR121-12VDC. . ......................... 5/36 1SFA611410R3506... MT-350B..................................... 1/39 1SNA645058R1300. . . OBOC 5000-115VAC/DC.. ............ 5/47 1SNA645575R0000. . . RBR121-AU-12VDC..................... 5/35 1SFA611940R1060... MA16-1060................................. 1/39 1SNA645059R1400. . . OBOC 5000-230VAC/DC.. ............ 5/47 1SNA684202R0100. . . ILPH RS 232 (24 V DC power supply).. 1SFA616920R8029... KA1-8029.................................... 1/39 1SNA645061R0600. . . OBOA 1000-48-60VAC/DC.. ......... 5/47 4/37 1SFA616920R8030... KA1-8030.................................... 1/39 1SNA645062R0700. . . OBOA 1000-115VAC/DC. . ............ 5/47 1SNA684212R2200. . . ILPH RS 422 - 485 / RS 422 - 485 (24 1SNA 1SNA645071R0000. . . RB121-24VDC............................. 5/36 V DC power supply)... 4/37 1SNA116900R2700. .. BADH V0..................................... 5/47 1SNA645072R0000. . . RB121-AU-24VDC....................... 5/35 1SNA684231R2500. . . ILPH RS 232 / RS 422-485.......... 4/37 1SNA206754R0000. .. BJ 612-20................................... 5/36 1SNA645073R0000. . . RB121-12VDC............................. 5/36 1SNA684232R2600. . . ILPH BdC /RS 422 - 485 (24 V DC 1SNA206754R0000. .. BJ 612-20................................... 5/47 1SNA645075R0000. . . RB121-AU-12VDC....................... 5/35 power supply). . .......... 4/37 1SNA290474R0200. .. SC 612. ....................................... 5/36 1SNA645501R0500. . . RBR121A-24VAC/DC................... 5/36 1SNA684233R2700. . . ILPH RS 232 / RS 422-485.......... 4/37 1SNA290474R0200. .. SC 612. ....................................... 5/47 1SNA645502R0600. . . RBR121A-48-60VUC................... 5/36 1SNA684234R0200. . . ILPH RS 232 / RS 232 (115-230 V AC 1SNA290488R0100. .. BJ 612-10................................... 5/36 1SNA645503R0700. . . RBR121A-115VAC/DC................. 5/36 power supply). . .......... 4/37 1SNA290488R0100. .. BJ 612-10................................... 5/47 1SNA645504R0000. . . RBR121A-230VAC/DC................. 5/36 1SNA684234R2000. . . ILPH RS 232 / RS 232 (24-48 V DC 1SNA399903R0200. .. BADL V0...................................... 5/47 1SNA645505R0100. . . RBR121A-24VAC/DC................... 5/35 power supply). . .......... 4/37 1SNA399967R0100. .. BAM2 V0..................................... 5/47 1SNA645506R0200. . . RBR121A-48-60VUC................... 5/35 1SNA684236R2200. . . ILPH RS 232 / FO-S (24...42 V AC/DC 1SNA645001R0300. .. RB121A-24VAC/DC..................... 5/36 1SNA645507R0300. . . RBR121A-115VAC/DC................. 5/35 power supply). . .......... 4/37 1SNA645002R0400. .. RB121A-48-60VAC/DC................ 5/36 1SNA645508R1400. . . RBR121A-230VAC/DC................. 5/35 1SNA684246R0400. . . ILPH RS 485 / FO-S (24...42 V AC/DC 1SNA645003R0500. .. RB121A-115VAC/DC................... 5/36 1SNA645511R2600. . . RBR121AR-230VAC/DC............... 5/36 power supply). . .......... 4/37 1SNA645004R0400. .. RB121A-230VAC/DC................... 5/36 1SNA645512R2700. . . RBR122A-24VAC/DC................... 5/36 1SNA684252R0200. . . ILPH RS 232-RS 485 / Ethernet.... 4/37 1SNA645005R0700. .. RB121A-24VAC/DC..................... 5/35 1SNA645513R2000. . . RBR122A-230VAC/DC................. 5/36 1SNA684333R2300. . . ILPH RS 232 / RS 422-485 (24-48 V 1SNA645006R0000. .. RB121A-48-60VAC/DC................ 5/35 1SNA645514R2100. . . RBR111A-24VAC/DC................... 5/35 DC power supply)...... 4/37 1SNA645007R0100. .. RB121A-115VAC/DC................... 5/35 1SNA645518R0500. . . RBR111AR-24VAC/DC. . ............... 5/35 1SNA684334R2400. . . ILPH RS 232 / RS 422-485 (115-230 1SNA645008R1200. .. RB121A-230VAC/DC................... 5/35 1SNA645519R0600. . . RBR101AR-24VAC/DC. . ............... 5/35 V AC power supply)... 4/37 1SNA645011R2400. .. RB121AR-230VAC/DC................. 5/36 1SNA645520R0300. . . RBR121A-60-230VUC.. ................ 5/36 1SNB041391R0610.. . CR-SM.......................................... 5/8 1SNA645012R2500. .. RB122A-24VAC/DC..................... 5/36 1SNA645521R2000. . . OBRIC 0100-24VDC.................... 5/47 1SVR 1SNA645013R2600. .. RB122A-230VAC/DC................... 5/36 1SNA645522R2100. . . OBRIC 0100-115-230VAC/DC...... 5/47 1SVR010200R1600... CC-E I/I-1...................................... 4/8 1SNA645014R2700. .. RB111A-24VAC/DC..................... 5/35 1SNA645524R2300. . . OBROC 5000-24VDC. . ................. 5/47 1SVR010201R0300... CC-E I/I-2...................................... 4/8 1SNA645016R2100. .. RB111A-115VAC/DC................... 5/35 1SNA645525R2400. . . OBROC 1500-24VAC/DC............. 5/47 1SVR010203R0500... CC-E IAC/ILPO............................ 4/11 1SNA645017R2200. .. RB111A-230VAC/DC................... 5/35 1SNA645526R2500. . . OBROC 1000-230VAC/DC........... 5/47 1SVR011700R0000... CC-E/STD..................................... 4/8 1SNA645018R0300. .. RB111AR-24VAC/DC................... 5/35 1SNA645527R2600. . . OBROA 1000-24VDC................... 5/47 1SVR011701R2500... CC-E/RTD..................................... 4/9 1SNA645019R0400. .. RB101AR-24VAC/DC................... 5/35 1SNA645528R0700. . . OBROA 1000-230VAC/DC........... 5/47 1SVR011702R2600... CC-E/TC..................................... 4/10 1SNA645020R0100. .. RB121A-60-230VUC. . .................. 5/36 1SNA645529R0000. . . OBROA 2000-24VDC................... 5/47 1SVR011703R2700... CC-E/I......................................... 4/11 1SNA645021R2600. .. OBIC 0100-24VDC. . ..................... 5/47 1SNA645531R2200. . . FC2............................................. 5/47 1SVR011705R2100... CC-E/STD..................................... 4/8 1SNA645022R2700. .. OBIC 0100-115-230VAC/DC........ 5/47 1SNA645534R2500. . . RBR121-5VDC. . ........................... 5/36 1SVR011706R2200... CC-E/RTD..................................... 4/9 1SNA645024R2100. .. OBOC 5000-24VDC..................... 5/47 1SNA645535R2600. . . RBR121-12VDC. . ......................... 5/36 1SVR011707R2300... CC-E/TC..................................... 4/10 1SNA645025R2200. .. OBOC 1500-24VAC/DC............... 5/47 1SNA645536R2700. . . RBR121-5VDC. . ........................... 5/35 1SVR011708R0400... CC-E/I......................................... 4/11 1SNA645026R2300. .. OBOC 1000-230VAC/DC.. ............ 5/47 1SNA645540R1700. . . RBR122A-48-60VUC................... 5/36 1SVR011710R2100... CC-E V/V. . ..................................... 4/8 1SNA645027R2400. .. OBOA 1000-24VDC..................... 5/47 1SNA645541R0400. . . RBR122A-115VAC/DC................. 5/36 1SVR011711R1600... CC-E V/I........................................ 4/8 1SNA645028R0500. .. OBOA 1000-230VAC/DC. . ............ 5/47 1SNA645546R0100. . . RBR121AR-115VAC/DC............... 5/36 1SVR011712R1700... CC-E V/I........................................ 4/8 1SNA645029R0600. .. OBOA 2000-24VDC..................... 5/47 1SNA645547R0200. . . OBRIC 0100-5-12VDC................. 5/47 1SVR011713R1000... CC-E I/V........................................ 4/8 1SNA645034R2300. .. RB121-5VDC............................... 5/36 1SNA645549R1400. . . OBRIC 0100-48-60VAC/DC. . ........ 5/47 1SVR011714R1100... CC-E I/I......................................... 4/8 1SNA645035R2400. .. RB121-12VDC............................. 5/36 1SNA645550R1100. . . OBROC 1000-5-12VDC............... 5/47 1SVR011715R1200... CC-E I/I......................................... 4/8 1SNA645036R2500. .. RB121-5VDC............................... 5/35 1SNA645551R0600. . . OBROC 1000-24VDC. . ................. 5/47 1SVR011716R1300... CC-E I/V........................................ 4/8 1SNA645040R1500. .. RB122A-48-60VAC/DC................ 5/36 1SNA645553R0000. . . OBROC 1000-48-60VAC/DC........ 5/47 1SVR011717R1400... CC-E I/I......................................... 4/8 1SNA645041R0200. .. RB122A-115VAC/DC................... 5/36 1SNA645554R0100. . . OBROC 1000-115VAC/DC........... 5/47 1SVR011718R2500... CC-E I/I......................................... 4/8 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/6 7 Index Numerical Order code 7 Type Page Order code Type Page Order code Type Page 1SVR011719R2600... CC-E V/V. ...................................... 4/8 1SVR011792R1000... CC-E RTD/I................................... 4/9 1SVR405541R3210... CR-S024VADC1CRZ...................... 5/8 1SVR011720R2300... CC-E V/V. ...................................... 4/8 1SVR011793R1100... CC-E RTD/I................................... 4/9 1SVR405541R3220... CR-S024VADC1CRGZ.................... 5/8 1SVR011721R1000... CC-E V/I........................................ 4/8 1SVR011794R1200... CC-E RTD/V.................................. 4/9 1SVR405541R6110... CR-S110VADC1CRS...................... 5/8 1SVR011722R1100... CC-E V/I........................................ 4/8 1SVR011795R1300... CC-E RTD/I................................... 4/9 1SVR405541R6120... CR-S110VADC1CRGS................... 5/8 1SVR011723R1200... CC-E V/V. ...................................... 4/8 1SVR011796R1400... CC-E RTD/I................................... 4/9 1SVR405541R6210... CR-S110VADC1CRZ...................... 5/8 1SVR011724R1300... CC-E I/I......................................... 4/8 1SVR011797R1500... CC-E RTD/V.................................. 4/9 1SVR405541R6220... CR-S110VADC1CRGZ.................... 5/8 1SVR011725R1400... CC-E I/I......................................... 4/8 1SVR011798R2600... CC-E RTD/I................................... 4/9 1SVR405541R7110... CR-S230VADC1CRS...................... 5/8 1SVR011726R1500... CC-E V/V. ...................................... 4/8 1SVR011799R2700... CC-E RTD/I................................... 4/9 1SVR405541R7120... CR-S230VADC1CRGS................... 5/8 1SVR011727R1600... CC-E I/I......................................... 4/8 1SVR040000R1700... CC-U/STD................................... 4/21 1SVR405541R7210... CR-S230VADC1CRZ...................... 5/8 1SVR011728R2700... CC-E I/I......................................... 4/8 1SVR040001R0400... CC-U/STD................................... 4/21 1SVR405541R7220... CR-S230VADC1CRGZ.................... 5/8 1SVR011729R2000... CC-E V/V. ...................................... 4/8 1SVR040002R0500... CC-U/RTD................................... 4/21 1SVR405598R0700... CR-SJB20-BLUE........................... 5/8 1SVR011730R2500... CC-E RTD/V.................................. 4/9 1SVR040003R0600... CC-U/RTD................................... 4/21 1SVR405598R0800... CR-SJB20-RED............................. 5/8 1SVR011731R1200... CC-E RTD/I................................... 4/9 1SVR040004R0700... CC-U/TC..................................... 4/21 1SVR405598R0900... CR-SJB20-BLACK......................... 5/8 1SVR011732R1300... CC-E RTD/I................................... 4/9 1SVR040005R0000... CC-U/TC..................................... 4/21 1SVR405599R0000... CR-SSEP. . ..................................... 5/8 1SVR011733R1400... CC-E RTD/V.................................. 4/9 1SVR040006R0100... CC-U/I. . ....................................... 4/21 1SVR405600R0000... CR-P024AC1. . ............................... 5/9 1SVR011734R1500... CC-E RTD/I................................... 4/9 1SVR040007R0200... CC-U/I. . ....................................... 4/21 1SVR405600R1000... CR-P024DC1. . ............................... 5/9 1SVR011735R1600... CC-E RTD/I................................... 4/9 1SVR040008R1300... CC-U/V....................................... 4/21 1SVR405600R2000... CR-P120AC1. . ............................... 5/9 1SVR011736R1700... CC-E RTD/V.................................. 4/9 1SVR040009R1400... CC-U/V....................................... 4/21 1SVR405600R3000... CR-P230AC1. . ............................... 5/9 1SVR011737R1000... CC-E RTD/I................................... 4/9 1SVR040010R0000... CC-U/STDR................................. 4/21 1SVR405600R4000... CR-P012DC1. . ............................... 5/9 1SVR011738R2100... CC-E RTD/I................................... 4/9 1SVR040011R2500... CC-U/STDR................................. 4/21 1SVR405600R5000... CR-P048AC1. . ............................... 5/9 1SVR011739R2200... CC-E RTD/V.................................. 4/9 1SVR040012R2600... CC-U/RTDR. . ............................... 4/21 1SVR405600R6000... CR-P048DC1. . ............................... 5/9 1SVR011740R0700... CC-E RTD/I................................... 4/9 1SVR040013R2700... CC-U/RTDR. . ............................... 4/21 1SVR405600R7000... CR-P110AC1. . ............................... 5/9 1SVR011741R2400... CC-E RTD/I................................... 4/9 1SVR040014R2000... CC-U/TCR................................... 4/21 1SVR405600R8000... CR-P110DC1. . ............................... 5/9 1SVR011750R0100... CC-E TC/V.................................. 4/10 1SVR040015R2100... CC-U/TCR................................... 4/21 1SVR405601R0000... CR-P024AC2. . ............................... 5/9 1SVR011751R2600... CC-E TC/I. ................................... 4/10 1SVR366017R0100... MAR.01....................................... 1/40 1SVR405601R1000... CR-P024DC2. . ............................... 5/9 1SVR011752R2700... CC-E TC/I. ................................... 4/10 1SVR366017R0100... MAR.01....................................... 1/40 1SVR405601R2000... CR-P120AC2. . ............................... 5/9 1SVR011753R2000... CC-E TC/V.................................. 4/10 1SVR366017R0100... MAR.01..................................... 2/130 1SVR405601R3000... CR-P230AC2. . ............................... 5/9 1SVR011754R2100... CC-E TC/I. ................................... 4/10 1SVR366017R0100... MAR.01....................................... 4/22 1SVR405601R4000... CR-P012DC2. . ............................... 5/9 1SVR011755R2200... CC-E TC/I. ................................... 4/10 1SVR402902R0000... CM-HE...................................... 2/116 1SVR405601R5000... CR-P048AC2. . ............................... 5/9 1SVR011760R0300... CC-E TC/V.................................. 4/10 1SVR405501R1010... CR-S005VDC1R............................ 5/8 1SVR405601R6000... CR-P048DC2. . ............................... 5/9 1SVR011761R2000... CC-E TC/I. ................................... 4/10 1SVR405501R1020... CR-S005VDC1RG.......................... 5/8 1SVR405601R7000... CR-P110AC2. . ............................... 5/9 1SVR011762R2100... CC-E TC/I. ................................... 4/10 1SVR405501R2010... CR-S012VDC1R............................ 5/8 1SVR405601R8000... CR-P110DC2. . ............................... 5/9 1SVR011763R2200... CC-E TC/V.................................. 4/10 1SVR405501R2020... CR-S012VDC1RG.......................... 5/8 1SVR405606R0000... CR-P024AC2G.............................. 5/9 1SVR011764R2300... CC-E TC/I. ................................... 4/10 1SVR405501R3010... CR-S024VDC1R............................ 5/8 1SVR405606R1000... CR-P024DC2. . ............................... 5/9 1SVR011765R2400... CC-E TC/I. ................................... 4/10 1SVR405501R3020... CR-S024VDC1RG.......................... 5/8 1SVR405606R3000... CR-P230AC2G.............................. 5/9 1SVR011770R0500... CC-E IAC/V................................. 4/11 1SVR405501R4010... CR-S048VDC1R............................ 5/8 1SVR405606R7000... CR-P110AC2G.............................. 5/9 1SVR011771R2200... CC-E IAC/I. .................................. 4/11 1SVR405501R4020... CR-S048VDC1RG.......................... 5/8 1SVR405611R0000... CR-M024AC2.............................. 5/10 1SVR011772R2300... CC-E IAC/I. .................................. 4/11 1SVR405501R5010... CR-S060VDC1R............................ 5/8 1SVR405611R0100... CR-M024AC2L............................ 5/11 1SVR011773R2400... CC-E IDC/V................................. 4/11 1SVR405501R5020... CR-S060VDC1RG.......................... 5/8 1SVR405611R1000... CR-M024DC2.............................. 5/10 1SVR011774R2500... CC-E IDC/I.................................. 4/11 1SVR405521R1100... CR-S006/024VDC1SS................... 5/8 1SVR405611R1100... CR-M024DC2L............................ 5/11 1SVR011775R2600... CC-E IDC/I.................................. 4/11 1SVR405521R1200... CR-S006/024VDC1SZ. . .................. 5/8 1SVR405611R2000... CR-M120AC2.............................. 5/10 1SVR011780R1100... CC-E IAC/V................................. 4/11 1SVR405521R3100... CR-S012/024VADC1SS................. 5/8 1SVR405611R2100... CR-M120AC2L............................ 5/11 1SVR011781R0600... CC-E IAC/I. .................................. 4/11 1SVR405521R3200... CR-S012/024VADC1SZ. . ................ 5/8 1SVR405611R3000... CR-M230AC2.............................. 5/10 1SVR011782R0700... CC-E IAC/I. .................................. 4/11 1SVR405521R5100... CR-S048/060VADC1SS................. 5/8 1SVR405611R3100... CR-M230AC2L............................ 5/11 1SVR011783R0000... CC-E IDC/V................................. 4/11 1SVR405521R5200... CR-S048/060VADC1SZ. . ................ 5/8 1SVR405611R4000... CR-M012DC2.............................. 5/10 1SVR011784R0100... CC-E IDC/I.................................. 4/11 1SVR405521R6100... CR-S110/125VADC1SS................. 5/8 1SVR405611R4100... CR-M012DC2L............................ 5/11 1SVR011785R1100... CC-E IDC/I.................................. 4/11 1SVR405521R6200... CR-S110/125VADC1SZ. . ................ 5/8 1SVR405611R4200... CR-M060DC2.............................. 5/10 1SVR011788R2400... CC-E RTD/V.................................. 4/9 1SVR405521R7100... CR-S220/240VADC1SS................. 5/8 1SVR405611R4300... CR-M060DC2L............................ 5/11 1SVR011789R2500... CC-E RTD/I................................... 4/9 1SVR405521R7200... CR-S220/240VADC1SZ. . ................ 5/8 1SVR405611R5000... CR-M048AC2.............................. 5/10 1SVR011790R2200... CC-E RTD/I................................... 4/9 1SVR405541R3110... CR-S024VADC1CRS...................... 5/8 1SVR405611R5100... CR-M048AC2L............................ 5/11 1SVR011791R1700... CC-E RTD/V.................................. 4/9 1SVR405541R3120... CR-S024VADC1CRGS................... 5/8 1SVR405611R6000... CR-M048DC2.............................. 5/10 2/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Index Numerical Order code Type Page Order code Type Page Order code Type Page 1SVR405611R6100... CR-M048DC2L............................ 5/11 1SVR405613R7100... CR-M110AC4L............................ 5/11 1SVR405611R7000... CR-M110AC2.............................. 5/10 1SVR405613R8000... CR-M110DC4.............................. 5/10 1SVR405622R2100... CR-U120AC3L. . ........................... 5/13 1SVR405622R3000... CR-U230AC3. . ............................. 5/13 1SVR405611R7100... CR-M110AC2L............................ 5/11 1SVR405613R8100... CR-M110DC4L............................ 5/11 1SVR405622R3100... CR-U230AC3L. . ........................... 5/13 1SVR405611R8000... CR-M110DC2.............................. 5/10 1SVR405613R8200... CR-M125DC4.............................. 5/10 1SVR405622R4000... CR-U012DC3.............................. 5/13 1SVR405611R8100... CR-M110DC2L............................ 5/11 1SVR405613R8300... CR-M125DC4L............................ 5/11 1SVR405622R4100... CR-U012DC3L. . ........................... 5/13 1SVR405611R8200... CR-M125DC2.............................. 5/10 1SVR405613R9000... CR-M220DC4.............................. 5/10 1SVR405622R5000... CR-U048AC3. . ............................. 5/13 1SVR405611R8300... CR-M125DC2L............................ 5/11 1SVR405613R9100... CR-M220DC4L............................ 5/11 1SVR405622R5100... CR-U048AC3L. . ........................... 5/13 1SVR405611R9000... CR-M220DC2.............................. 5/10 1SVR405614R1100... CR-M024DC4LD. . ........................ 5/11 1SVR405622R5200... CR-U060AC3. . ............................. 5/13 1SVR405611R9100... CR-M220DC2L............................ 5/11 1SVR405618R0000... CR-M024AC4G. . .......................... 5/11 1SVR405622R6000... CR-U048DC3.............................. 5/13 1SVR405612R0000... CR-M024AC3.............................. 5/10 1SVR405618R0100... CR-M024AC4LG. . ........................ 5/11 1SVR405622R6100... CR-U048DC3L. . ........................... 5/13 1SVR405612R0100... CR-M024AC3L............................ 5/11 1SVR405618R1000... CR-M024DC4G........................... 5/11 1SVR405622R7000... CR-U110AC3. . ............................. 5/13 1SVR405612R1000... CR-M024DC3.............................. 5/10 1SVR405618R1100... CR-M024DC4LG. . ........................ 5/11 1SVR405622R7100... CR-U110AC3L. . ........................... 5/13 1SVR405612R1100... CR-M024DC3L............................ 5/11 1SVR405618R1400... CR-M024DC4LDG....................... 5/11 1SVR405622R8000... CR-U110DC3.............................. 5/13 1SVR405612R2000... CR-M120AC3.............................. 5/10 1SVR405618R2100... CR-M120AC4LG. . ........................ 5/11 1SVR405622R8100... CR-U110DC3L. . ........................... 5/13 1SVR405612R2100... CR-M120AC3L............................ 5/11 1SVR405618R3000... CR-M230AC4G. . .......................... 5/11 1SVR405622R8200... CR-U125DC3.............................. 5/13 1SVR405612R3000... CR-M230AC3.............................. 5/10 1SVR405618R3100... CR-M230AC4LG. . ........................ 5/11 1SVR405622R9000... CR-U220DC3.............................. 5/13 1SVR405612R3100... CR-M230AC3L............................ 5/11 1SVR405618R4100... CR-M012DC4LG. . ........................ 5/11 1SVR405622R9100... CR-U220DC3L. . ........................... 5/13 1SVR405612R4000... CR-M012DC3.............................. 5/10 1SVR405618R4300... CR-M060DC4LG. . ........................ 5/11 1SVR405650R0000... CR-PLS......................................... 5/9 1SVR405612R4100... CR-M012DC3L............................ 5/11 1SVR405618R4400... CR-M012DC4LDG....................... 5/11 1SVR405650R0100... CR-PLSx....................................... 5/9 1SVR405612R4200... CR-M060DC3.............................. 5/10 1SVR405618R5100... CR-M048AC4LG. . ........................ 5/11 1SVR405650R0200... CR-PLC. . ....................................... 5/9 1SVR405612R4300... CR-M060DC3L............................ 5/11 1SVR405618R6100... CR-M048DC4LG. . ........................ 5/11 1SVR405650R1000... CR-PSS. . ....................................... 5/9 1SVR405612R5000... CR-M048AC3.............................. 5/10 1SVR405618R7000... CR-M110AC4G. . .......................... 5/11 1SVR405651R0000... CR-P/M 22.................................. 5/12 1SVR405612R5100... CR-M048AC3L............................ 5/11 1SVR405618R7100... CR-M110AC4LG. . ........................ 5/11 1SVR405651R1000... CR-M2SS.................................... 5/11 1SVR405612R5200... CR-M060AC3.............................. 5/10 1SVR405618R8100... CR-M110DC4LG. . ........................ 5/11 1SVR405651R1100... CR-M2LS.................................... 5/11 1SVR405612R6000... CR-M048DC3.............................. 5/10 1SVR405618R8300... CR-M125DC4LG. . ........................ 5/11 1SVR405651R1200... CR-M2LC.................................... 5/11 1SVR405612R6100... CR-M048DC3L............................ 5/11 1SVR405618R9100... CR-M220DC4LG. . ........................ 5/11 1SVR405651R1300... CR-M2SF.................................... 5/11 1SVR405612R7000... CR-M110AC3.............................. 5/10 1SVR405621R0000... CR-U024AC2. . ............................. 5/13 1SVR405651R2000... CR-M3SS.................................... 5/11 1SVR405612R7100... CR-M110AC3L............................ 5/11 1SVR405621R0100... CR-U024AC2L. . ........................... 5/13 1SVR405651R2100... CR-M3LS.................................... 5/11 1SVR405612R8000... CR-M110DC3.............................. 5/10 1SVR405621R1000... CR-U024DC2.............................. 5/13 1SVR405651R3000... CR-M4SS.................................... 5/11 1SVR405612R8100... CR-M110DC3L............................ 5/11 1SVR405621R1100... CR-U024DC2L. . ........................... 5/13 1SVR405651R3100... CR-M4LS.................................... 5/11 1SVR405612R8200... CR-M125DC3.............................. 5/10 1SVR405621R2000... CR-U120AC2. . ............................. 5/13 1SVR405651R3200... CR-M4LC.................................... 5/11 1SVR405612R8300... CR-M125DC3L............................ 5/11 1SVR405621R2100... CR-U120AC2L. . ........................... 5/13 1SVR405651R3300... CR-M4SF.................................... 5/11 1SVR405612R9000... CR-M220DC3.............................. 5/10 1SVR405621R3000... CR-U230AC2. . ............................. 5/13 1SVR405652R0000... CR-P/M 42.................................. 5/12 1SVR405612R9100... CR-M220DC3L............................ 5/11 1SVR405621R3100... CR-U230AC2L. . ........................... 5/13 1SVR405652R1000... CR-P/M 42V................................ 5/12 1SVR405613R0000... CR-M024AC4.............................. 5/10 1SVR405621R4000 .CR-U012DC2.............................. 5/13 1SVR405652R4000... CR-P/M 42B................................ 5/12 1SVR405613R0100... CR-M024AC4L............................ 5/11 1SVR405621R4100... CR-U012DC2L. . ........................... 5/13 1SVR405652R4100... CR-P/M 42BV.............................. 5/12 1SVR405613R1000... CR-M024DC4.............................. 5/10 1SVR405621R5000... CR-U048AC2. . ............................. 5/13 1SVR405652R9000... CR-P/M 42C. . .............................. 5/12 1SVR405613R1100... CR-M024DC4L............................ 5/11 1SVR405621R5100... CR-U048AC2L. . ........................... 5/13 1SVR405652R9100... CR-P/M 42CV. . ............................ 5/12 1SVR405613R2000... CR-M120AC4.............................. 5/10 1SVR405621R6000... CR-U048DC2.............................. 5/13 1SVR405653R0000... CR-P/M 52B................................ 5/12 1SVR405613R2100... CR-M120AC4L............................ 5/11 1SVR405621R6100... CR-U048DC2L. . ........................... 5/13 1SVR405653R1000... CR-P/M 52C. . .............................. 5/12 1SVR405613R3000... CR-M230AC4.............................. 5/10 1SVR405621R7000... CR-U110AC2. . ............................. 5/13 1SVR405653R4000... CR-P/M 52D................................ 5/12 1SVR405613R3100... CR-M230AC4L............................ 5/11 1SVR405621R7100... CR-U110AC2L. . ........................... 5/13 1SVR405654R0000... CR-P/M 62.................................. 5/12 1SVR405613R4000... CR-M012DC4.............................. 5/10 1SVR405621R8000... CR-U110DC2.............................. 5/13 1SVR405654R0100... CR-P/M 92.................................. 5/12 1SVR405613R4100... CR-M012DC4L............................ 5/11 1SVR405621R8100... CR-U110DC2L. . ........................... 5/13 1SVR405654R1000... CR-P/M 62V................................ 5/12 1SVR405613R4200... CR-M060DC4.............................. 5/10 1SVR405621R9000... CR-U220DC2.............................. 5/13 1SVR405654R1100... CR-P/M 92V................................ 5/12 1SVR405613R4300... CR-M060DC4L............................ 5/11 1SVR405621R9100... CR-U220DC2L. . ........................... 5/13 1SVR405654R4000... CR-P/M 62E................................ 5/12 1SVR405613R5000... CR-M048AC4.............................. 5/10 1SVR405622R0000... CR-U024AC3. . ............................. 5/13 1SVR405654R4100... CR-P/M 62EV.............................. 5/12 1SVR405613R5100... CR-M048AC4L............................ 5/11 1SVR405622R0100... CR-U024AC3L. . ........................... 5/13 1SVR405655R0000... CR-P/M 62C. . .............................. 5/12 1SVR405613R6000... CR-M048DC4.............................. 5/10 1SVR405622R1000... CR-U024DC3.............................. 5/13 1SVR405655R0100... CR-P/M 92C. . .............................. 5/12 1SVR405613R6100... CR-M048DC4L............................ 5/11 1SVR405622R1100... CR-U024DC3L. . ........................... 5/13 1SVR405655R1000... CR-P/M 62CV. . ............................ 5/12 1SVR405613R7000... CR-M110AC4.............................. 5/10 1SVR405622R2000... CR-U120AC3. . ............................. 5/13 1SVR405655R1100... CR-P/M 92CV. . ............................ 5/12 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/8 7 Index Numerical Order code 7 Type Page Order code Type Page Order code Type Page 1SVR405655R4000... CR-P/M 62D................................ 5/12 1SVR427030R0000... CP-E 24/0.75.............................. 3/20 1SVR430851R1100... CM-ENS.................................... 2/115 1SVR405655R4100... CR-P/M 62DV. . ............................ 5/12 1SVR427030R2000... CP-E 48/0.62.............................. 3/20 1SVR430851R1200... CM-ENS UP/DOWN................... 2/115 1SVR405656R0000... CR-P/M 72.................................. 5/12 1SVR427031R0000... CP-E 24/1.25.............................. 3/20 1SVR430851R1300... CM-ENS.................................... 2/115 1SVR405656R1000... CR-P/M 72A................................ 5/12 1SVR427031R2000... CP-E 48/1.25.............................. 3/20 1SVR430851R9100... CM-ENS.................................... 2/115 1SVR405656R2000... CR-P/M 82.................................. 5/12 1SVR427032R0000... CP-E 24/2.5................................ 3/20 1SVR430851R9200... CM-ENS UP/DOWN................... 2/115 1SVR405658R0000... CR-PM.......................................... 5/9 1SVR427032R1000... CP-E 12/2.5................................ 3/20 1SVR440005R0100... COV.02. . .................................... 2/130 1SVR405658R1000... CR-MM....................................... 5/11 1SVR427033R3000... CP-E 5/3.0.................................. 3/20 1SVR440029R0100... ADP.02...................................... 2/130 1SVR405658R5000... CR-PJ........................................... 5/9 1SVR427034R0000... CP-E 24/5.0................................ 3/20 1SVR440709R0000... CL-LEC.CI000............................... 6/7 1SVR405658R6000... CR-MJ......................................... 5/11 1SVR427034R2000... CP-E 48/5.0................................ 3/20 1SVR440709R5000... CL-LER.2O.................................... 6/7 1SVR405659R0000... CR-PH........................................... 5/9 1SVR427035R0000... CP-E 24/10.0.............................. 3/20 1SVR440710R0200... CL-LSR.CX12DC1.. ........................ 6/6 1SVR405659R1000... CR-MH........................................ 5/11 1SVR427035R1000... CP-E 12/10.0.............................. 3/20 1SVR440710R0300... CL-LSR.C12DC1........................... 6/6 1SVR405659R1100... CR-MH1...................................... 5/11 1SVR427035R2000... CP-E 48/10.0.............................. 3/20 1SVR440711R0100... CL-LSR.12DC2.............................. 6/6 1SVR405660R0000... CR-U3S. ...................................... 5/13 1SVR427036R0000... CP-E 24/20.0.............................. 3/20 1SVR440711R0200... CL-LSR.CX12DC2.. ........................ 6/6 1SVR405660R0100... CR-U3E....................................... 5/13 1SVR427041R0000... CP-D 24/0.42.............................. 3/10 1SVR440711R0300... CL-LSR.C12DC2........................... 6/6 1SVR405660R1100... CR-U3SM.................................... 5/13 1SVR427041R0000... CP-D 24/0.42................................ 6/8 1SVR440711R1200... CL-LST.CX12DC2.......................... 6/6 1SVR405661R0000... CR-U 21...................................... 5/14 1SVR427041R1000... CP-D 12/0.83.............................. 3/10 1SVR440711R1300... CL-LST.C12DC2............................ 6/6 1SVR405662R0000... CR-U 41...................................... 5/14 1SVR427043R0100... CP-D 24/1.3................................ 3/10 1SVR440712R0200... CL-LSR.CX12AC1. . ........................ 6/6 1SVR405662R1000... CR-U 41V.................................... 5/14 1SVR427043R0100... CP-D 24/1.3.................................. 6/8 1SVR440712R0300... CL-LSR.C12AC1. . .......................... 6/6 1SVR405662R4000... CR-U 41B. ................................... 5/14 1SVR427043R1200... CP-D 12/2.1................................ 3/10 1SVR440713R0100... CL-LSR.12AC2.............................. 6/6 1SVR405662R4100... CR-U 41BV. ................................. 5/14 1SVR427044R0200... CP-D 24/2.5................................ 3/10 1SVR440713R0200... CL-LSR.CX12AC2. . ........................ 6/6 1SVR405662R9000... CR-U 41C.................................... 5/14 1SVR427045R0400... CP-D 24/4.2................................ 3/10 1SVR440713R0300... CL-LSR.C12AC2. . .......................... 6/6 1SVR405662R9100... CR-U 41CV.................................. 5/14 1SVR427049R0000... CP-D RU..................................... 3/51 1SVR440720R0200... CL-LMR.CX18DC1......................... 6/7 1SVR405663R0000... CR-U 51B. ................................... 5/14 1SVR427054R0000... CP-T 24/5.0.. ............................... 3/34 1SVR440720R0300... CL-LMR.C18DC1. . ......................... 6/7 1SVR405663R1000... CR-U 51C.................................... 5/14 1SVR427054R2000... CP-T 48/5.0.. ............................... 3/34 1SVR440721R0000... CL-LER.18DC2.............................. 6/7 1SVR405663R4000... CR-U 51D. ................................... 5/14 1SVR427055R0000... CP-T 24/10.0. . ............................. 3/34 1SVR440721R0200... CL-LMR.CX18DC2......................... 6/7 1SVR405664R0000... CR-U 61...................................... 5/14 1SVR427055R2000... CP-T 48/10.0. . ............................. 3/34 1SVR440721R0300... CL-LMR.C18DC2. . ......................... 6/7 1SVR405664R0100... CR-U 91...................................... 5/14 1SVR427056R0000... CP-T 24/20.0. . ............................. 3/34 1SVR440721R1000... CL-LET.20DC2. . ............................. 6/7 1SVR405664R1000... CR-U 61V.................................... 5/14 1SVR427056R2000... CP-T 48/20.0. . ............................. 3/34 1SVR440721R1200... CL-LMT.CX20DC2.. ........................ 6/7 1SVR405664R1100... CR-U 91V.................................... 5/14 1SVR427057R0000... CP-T 24/40.0. . ............................. 3/34 1SVR440721R1300... CL-LMT.C20DC2.. .......................... 6/7 1SVR405664R4000... CR-U 61E.................................... 5/14 1SVR427060R0300... CP-B 24/3.0................................ 3/68 1SVR440722R0200... CL-LMR.CX18AC1......................... 6/7 1SVR405664R4100... CR-U 61EV.................................. 5/14 1SVR427060R1000... CP-B 24/10.0.............................. 3/68 1SVR440722R0300... CL-LMR.C18AC1........................... 6/7 1SVR405665R0000... CR-U 61C.................................... 5/14 1SVR427060R2000... CP-B 24/20.0.............................. 3/68 1SVR440723R0000... CL-LER.18AC2.............................. 6/7 1SVR405665R0100... CR-U 91C.................................... 5/14 1SVR427065R0000... CP-B EXT.2.. ................................ 3/68 1SVR440723R0200... CL-LMR.CX18AC2......................... 6/7 1SVR405665R1000... CR-U 61CV.................................. 5/14 1SVR427071R0000... CP-A RU..................................... 3/51 1SVR440723R0300... CL-LMR.C18AC2........................... 6/7 1SVR405665R1100... CR-U 91CV.................................. 5/14 1SVR427075R0000... CP-A CM..................................... 3/51 1SVR440799R5000... CL-LAS.FD001.. ............................. 6/8 1SVR405665R4000... CR-U 61D. ................................... 5/14 1SVR427081R0000... CP-C MM.................................... 3/45 1SVR440799R5100... CL-LAS.TK011.. ............................. 6/8 1SVR405665R4100... CR-U 61DV. ................................. 5/14 1SVR427090R0280... CP-ASI/2.8.................................. 3/60 1SVR440799R6000... CL-LAS.TK001.. ............................. 6/8 1SVR405666R0000... CR-U 71...................................... 5/14 1SVR427090R0400... CP-ASI/4.0.................................. 3/60 1SVR440799R6100... CL-LAS.TK002.. ............................. 6/8 1SVR405666R1000... CR-U 71A. ................................... 5/14 1SVR427090R0800... CP-ASI/8.0.................................. 3/60 1SVR440799R7000... CL-LAS.MD003.. ............................ 6/8 1SVR405666R2000... CR-U 81...................................... 5/14 1SVR427095R0400... CP-ASI/4.0 DC/DC.. ..................... 3/60 1SVR440799R8000... CL-LAS.PS002.............................. 6/8 1SVR405667R0000... CR-U T........................................ 5/14 1SVR430005R0100... COV.01. . ...................................... 1/40 1SVR440821R0000... CL-LDC.LDC2.. .............................. 6/9 1SVR405669R0000... CR-UH........................................ 5/13 1SVR430005R0100... COV.01. . .................................... 2/130 1SVR440821R1000... CL-LDC.LNDC2............................. 6/9 1SVR405670R0000... CR-U2S. ...................................... 5/13 1SVR430005R0100... COV.01. . ...................................... 4/22 1SVR440823R0000... CL-LDC.LAC2. . .............................. 6/9 1SVR405670R1100... CR-U2SM.................................... 5/13 1SVR430029R0100... ADP.01........................................ 1/40 1SVR440823R1000... CL-LDC.LNAC2............................. 6/9 1SVR423418R9000... CP-RUD...................................... 3/51 1SVR430029R0100... ADP.01........................................ 1/40 1SVR440839R4400... CL-LDD.K...................................... 6/6 1SVR427014R0000... CP-S 24/5.0................................ 3/45 1SVR430029R0100... ADP.01...................................... 2/130 1SVR440839R4400... CL-LDD.K...................................... 6/9 1SVR427015R0100... CP-S 24/10.0.............................. 3/45 1SVR430029R0100... ADP.01........................................ 4/22 1SVR440839R4500... CL-LDD.XK.................................... 6/6 1SVR427016R0100... CP-S 24/20.0.............................. 3/45 1SVR430043R0000... MAR.02....................................... 1/40 1SVR440839R4500... CL-LDD.XK.................................... 6/9 1SVR427024R0000... CP-C 24/5.0................................ 3/45 1SVR430043R0000... MAR.02..................................... 2/130 1SVR440841R0000... CL-LDC.SDC2............................... 6/6 1SVR427025R0000... CP-C 24/10.0.............................. 3/45 1SVR430851R0100... CM-ENS.................................... 2/115 1SVR440843R0000... CL-LDC.SAC2............................... 6/6 1SVR427026R0000... CP-C 24/20.0.............................. 3/45 1SVR430851R0200... CM-ENS UP/DOWN................... 2/115 1SVR440851R0000... CL-LDR.16DC2. . ............................ 6/9 2/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Index Numerical Order code Type Page Order code Type Page Order code Type Page 1SVR440851R1000... CL-LDT.16DC2.............................. 6/9 1SVR450332R0100... CM-LWN..................................... 2/76 1SVR550141R1100... CT-AWE . . .................................... 1/21 1SVR440851R2000... CL-LDR.17DC2. . ............................ 6/9 1SVR450334R0000... CM-LWN..................................... 2/76 1SVR550141R2100... CT-AWE . . .................................... 1/21 1SVR440851R3000... CL-LDT.17DC2.............................. 6/9 1SVR450334R0100... CM-LWN..................................... 2/76 1SVR550141R4100... CT-AWE . . .................................... 1/21 1SVR440853R0000... CL-LDR.16AC2.............................. 6/9 1SVR450335R0000... CM-LWN..................................... 2/76 1SVR550148R1100... CT-AWE . . .................................... 1/21 1SVR440899R1000... CL-LAD.FD001.............................. 6/9 1SVR450335R0100... CM-LWN..................................... 2/76 1SVR550148R2100... CT-AWE . . .................................... 1/21 1SVR440899R2000... CL-LAD.FD011.............................. 6/9 1SVR500020R0000... CT-MFD.12.................................... 1/8 1SVR550148R4100... CT-AWE . . .................................... 1/21 1SVR440899R3000... CL-LAD.FD002.............................. 6/9 1SVR500020R1100... CT-MFD.21.................................... 1/8 1SVR550150R3100... CT-AWE. . ..................................... 1/20 1SVR440899R6000... CL-LAD.TK001.............................. 6/9 1SVR500100R0000... CT-ERD.12.................................... 1/8 1SVR550151R3100... CT-AWE. . ..................................... 1/20 1SVR440899R6100... CL-LAD.TK002.............................. 6/9 1SVR500100R0100... CT-ERD.22.................................... 1/8 1SVR550158R3100... CT-AWE. . ..................................... 1/20 1SVR440899R6200... CL-LAD.TK003.............................. 6/9 1SVR500110R0000... CT-AHD.12.................................... 1/8 1SVR550160R1100... CT-EBE.. ...................................... 1/21 1SVR440899R6300... CL-LAD.TK004.............................. 6/9 1SVR500110R0100... CT-AHD.22.................................... 1/8 1SVR550167R1100... CT-EBE.. ...................................... 1/21 1SVR440899R6400... CL-LAD.TK005.............................. 6/9 1SVR500130R0000... CT-VWD.12. . .................................. 1/8 1SVR550200R1100... CT-YDE....................................... 1/21 1SVR440899R6500... CL-LAD.TK006.............................. 6/9 1SVR500150R0000... CT-EBD.12.................................... 1/8 1SVR550200R2100... CT-YDE....................................... 1/21 1SVR440899R6600... CL-LAD.TK007.............................. 6/8 1SVR500160R0000... CT-TGD.12.................................... 1/8 1SVR550200R4100... CT-YDE....................................... 1/21 1SVR440899R6700... CL-LAD.TK011.............................. 6/9 1SVR500160R0100... CT-TGD.22.................................... 1/8 1SVR550207R1100... CT-YDE....................................... 1/21 1SVR440899R6900... CL-LAD.TK009.............................. 6/9 1SVR500210R0100... CT-SAD.22.................................... 1/8 1SVR550207R2100... CT-YDE....................................... 1/21 1SVR440899R7000... CL-LAD.MD004............................. 6/9 1SVR500211R0100... CT-SDD.22.................................... 1/8 1SVR550207R4100... CT-YDE....................................... 1/21 1SVR450050R0000... CM-ENN. ................................... 2/115 1SVR510730R0300... CM-UFD.M22.............................. 2/54 1SVR550210R4100... CT-SDE....................................... 1/21 1SVR450051R0000... CM-ENN. ................................... 2/115 1SVR510730R0300... CM-UFD.M31.............................. 2/54 1SVR550212R4100... CT-SDE....................................... 1/21 1SVR450055R0000... CM-ENN. ................................... 2/115 1SVR550019R0000... CT-MKE....................................... 1/21 1SVR550217R4100... CT-SDE....................................... 1/21 1SVR450056R0000... CM-SE-300............................... 2/116 1SVR550029R8100... CT-MFE....................................... 1/20 1SVR550509R1000... CT-EKE. . ...................................... 1/21 1SVR450056R0100... CM-SE-600............................... 2/116 1SVR550100R1100... CT-ERE.. ...................................... 1/20 1SVR550509R2000... CT-EKE. . ...................................... 1/21 1SVR450056R0200... CM-SE-1000............................. 2/116 1SVR550100R2100... CT-ERE.. ...................................... 1/20 1SVR550509R4000... CT-EKE. . ...................................... 1/21 1SVR450056R6000... CM-KH-3. .................................. 2/116 1SVR550100R4100... CT-ERE.. ...................................... 1/20 1SVR550519R1000... CT-AKE.. ...................................... 1/21 1SVR450056R7000... CM-AH-3. . ................................. 2/116 1SVR550100R5100... CT-ERE.. ...................................... 1/20 1SVR550519R2000... CT-AKE.. ...................................... 1/21 1SVR450056R8000... CM-GM-1.................................. 2/116 1SVR550107R1100... CT-ERE.. ...................................... 1/20 1SVR550519R4000... CT-AKE.. ...................................... 1/21 1SVR450059R0000... CM-ENN. ................................... 2/115 1SVR550107R2100... CT-ERE.. ...................................... 1/20 1SVR550800R9300... CM-MSE.. .................................... 2/90 1SVR450116R1000... CM-CT 50/1.............................. 2/131 1SVR550107R4100... CT-ERE.. ...................................... 1/20 1SVR550801R9300... CM-MSE.. .................................... 2/90 1SVR450116R1100... CM-CT 75/1.............................. 2/131 1SVR550107R5100... CT-ERE.. ...................................... 1/20 1SVR550805R9300... CM-MSE.. .................................... 2/90 1SVR450116R1200... CM-CT 100/1............................ 2/131 1SVR550110R1100... CT-AHE....................................... 1/20 1SVR550824R9100... CM-PFE.. ..................................... 2/33 1SVR450116R1300... CM-CT 150/1............................ 2/131 1SVR550110R2100... CT-AHE....................................... 1/20 1SVR550850R9400... CM-ENE MAX............................ 2/115 1SVR450116R1400... CM-CT 200/1............................ 2/131 1SVR550110R4100... CT-AHE....................................... 1/20 1SVR550850R9500... CM-ENE MIN............................. 2/115 1SVR450116R5000... CM-CT 50/5.............................. 2/131 1SVR550111R1100... CT-AHE....................................... 1/20 1SVR550851R9400... CM-ENE MAX............................ 2/115 1SVR450116R5100... CM-CT 75/5.............................. 2/131 1SVR550111R2100... CT-AHE....................................... 1/20 1SVR550851R9500... CM-ENE MIN............................. 2/115 1SVR450116R5200... CM-CT 100/5............................ 2/131 1SVR550111R4100... CT-AHE....................................... 1/20 1SVR550855R9400... CM-ENE MAX............................ 2/115 1SVR450116R5300... CM-CT 150/5............................ 2/131 1SVR550118R1100... CT-AHE....................................... 1/20 1SVR550855R9500... CM-ENE MIN............................. 2/115 1SVR450116R5400... CM-CT 200/5............................ 2/131 1SVR550118R2100... CT-AHE....................................... 1/20 1SVR550870R9400... CM-PVE...................................... 2/33 1SVR450117R1100... CM-CT 300/1............................ 2/131 1SVR550118R4100... CT-AHE....................................... 1/20 1SVR550871R9500... CM-PVE...................................... 2/33 1SVR450117R1200... CM-CT 400/1............................ 2/131 1SVR550120R1100... CT-ARE....................................... 1/20 1SVR550881R9400... CM-PBE...................................... 2/33 1SVR450117R1300... CM-CT 500/1............................ 2/131 1SVR550120R4100... CT-ARE....................................... 1/20 1SVR550882R9500... CM-PBE...................................... 2/33 1SVR450117R1400... CM-CT 600/1............................ 2/131 1SVR550127R1100... CT-ARE....................................... 1/20 1SVR560730R3400... CM-UFD.M33.............................. 2/54 1SVR450117R5100... CM-CT 300/5............................ 2/131 1SVR550127R4100... CT-ARE....................................... 1/20 1SVR700101R0100... C512-D..................................... 2/104 1SVR450117R5200... CM-CT 400/5............................ 2/131 1SVR550130R1100... CT-VWE. . ..................................... 1/20 1SVR700102R0100... C512-E. . .................................... 2/104 1SVR450117R5300... CM-CT 500/5............................ 2/131 1SVR550130R2100... CT-VWE. . ..................................... 1/20 1SVR700111R0100... C513-D..................................... 2/104 1SVR450117R5400... CM-CT 600/5............................ 2/131 1SVR550130R4100... CT-VWE. . ..................................... 1/20 1SVR700112R0100... C513-E. . .................................... 2/104 1SVR450118R1000... CM-CT A................................... 2/131 1SVR550137R1100... CT-VWE. . ..................................... 1/20 1SVR730005R0100... COV.11. . ...................................... 1/40 1SVR450330R0000... CM-LWN..................................... 2/76 1SVR550137R2100... CT-VWE. . ..................................... 1/20 1SVR730005R0100... COV.11. . .................................... 2/130 1SVR450330R0100... CM-LWN..................................... 2/76 1SVR550137R4100... CT-VWE. . ..................................... 1/20 1SVR730006R0000... MAR.12....................................... 1/40 1SVR450331R0000... CM-LWN..................................... 2/76 1SVR550140R1100... CT-AWE . . .................................... 1/21 1SVR730006R0000... MAR.12..................................... 2/130 1SVR450331R0100... CM-LWN..................................... 2/76 1SVR550140R2100... CT-AWE . . .................................... 1/21 1SVR730010R0200... CT-MFS.21.................................. 1/37 1SVR450332R0000... CM-LWN..................................... 2/76 1SVR550140R4100... CT-AWE . . .................................... 1/21 1SVR730010R3200... CT-MBS.22S. . .............................. 1/37 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/10 7 Index Numerical Order code 7 Type Page Order code Type Page Order code Type Page 1SVR730020R0200... CT-MVS.21S................................ 1/37 1SVR730831R0400... CM-ESS.2S................................. 2/16 1SVR740712R1400... CM-MSS.31P.. ............................. 2/90 1SVR730020R3100... CT-MVS.12S................................ 1/37 1SVR730831R1300... CM-ESS.1S................................. 2/16 1SVR740712R2200... CM-MSS.33P.. ............................. 2/90 1SVR730020R3300... CT-MVS.22S................................ 1/37 1SVR730831R1400... CM-ESS.2S................................. 2/16 1SVR740720R1400... CM-MSS.11P.. ............................. 2/90 1SVR730021R2300... CT-MVS.23S................................ 1/37 1SVR730840R0200... CM-SRS.11S............................... 2/15 1SVR740722R1400... CM-MSS.21P.. ............................. 2/90 1SVR730030R3300... CT- MXS.22S............................... 1/37 1SVR730840R0300... CM-SRS.12S............................... 2/15 1SVR740740R0100... CM-TCS.11P ............................ 2/104 1SVR730040R3300... CT-WBS.22S............................... 1/37 1SVR730840R0400... CM-SRS.21S............................... 2/15 1SVR740740R0200... CM-TCS.12P ............................ 2/104 1SVR730100R0300... CT-ERS.21S................................ 1/38 1SVR730840R0500... CM-SRS.22S............................... 2/15 1SVR740740R0300... CM-TCS.13P ............................ 2/104 1SVR730100R3100... CT-ERS.12S................................ 1/38 1SVR730840R0600... CM-SRS.M1S.............................. 2/15 1SVR740740R9100... CM-TCS.21P ............................ 2/104 1SVR730100R3300... CT-ERS.22S................................ 1/38 1SVR730840R0700... CM-SRS.M2S.............................. 2/15 1SVR740740R9200... CM-TCS.22P ............................ 2/104 1SVR730110R3300... CT-AHS.22S................................ 1/38 1SVR730841R0200... CM-SRS.11S............................... 2/15 1SVR740740R9300... CM-TCS.23P ............................ 2/104 1SVR730120R3100... CT-ARS.11S................................ 1/38 1SVR730841R0300... CM-SRS.12S............................... 2/15 1SVR740750R0400... CM-EFS.2P................................. 2/16 1SVR730120R3300... CT-ARS.21S................................ 1/38 1SVR730841R0400... CM-SRS.21S............................... 2/15 1SVR740760R0400... CM-SFS.21P............................... 2/15 1SVR730180R0300... CT-APS.21S................................ 1/38 1SVR730841R0500... CM-SRS.22S............................... 2/15 1SVR740774R1300... CM-PAS.31P............................... 2/33 1SVR730180R3100... CT-APS.12S................................ 1/38 1SVR730841R1200... CM-SRS.11S............................... 2/15 1SVR740774R3300... CM-PAS.41P............................... 2/33 1SVR730180R3300... CT-APS.22S................................ 1/38 1SVR730841R1300... CM-SRS.12S............................... 2/15 1SVR740784R2300... CM-PSS.31P............................... 2/33 1SVR730210R3300... CT-SDS.22S................................ 1/38 1SVR730841R1400... CM-SRS.21S............................... 2/15 1SVR740784R3300... CM-PSS.41P............................... 2/33 1SVR730211R2300... CT-SDS.23S................................ 1/38 1SVR730841R1500... CM-SRS.22S............................... 2/15 1SVR740794R1300... CM-PVS.31P............................... 2/33 1SVR730660R0100... CM-IWS.1S.................................. 2/66 1SVR730884R1300... CM-MPS.31S.. ............................. 2/34 1SVR740794R2300... CM-PVS.81P............................... 2/33 1SVR730670R0200... CM-IWS.2S.................................. 2/66 1SVR730884R3300... CM-MPS.41S.. ............................. 2/34 1SVR740794R3300... CM-PVS.41P............................... 2/33 1SVR730700R0100... CM-MSS.12S.. ............................. 2/90 1SVR730884R4300... CM-MPS.43S.. ............................. 2/34 1SVR740824R9300... CM-PFS.P................................... 2/33 1SVR730700R0200... CM-MSS.22S.. ............................. 2/90 1SVR730885R1300... CM-MPS.11S.. ............................. 2/34 1SVR740830R0300... CM-ESS.1P................................. 2/16 1SVR730700R2100... CM-MSS.13S.. ............................. 2/90 1SVR730885R3300... CM-MPS.21S.. ............................. 2/34 1SVR740830R0400... CM-ESS.2P................................. 2/16 1SVR730700R2200... CM-MSS.23S.. ............................. 2/90 1SVR730885R4300... CM-MPS.23S.. ............................. 2/34 1SVR740830R0500... CM-ESS.MP................................ 2/16 1SVR730712R0200... CM-MSS.32S.. ............................. 2/90 1SVR740010R0200... CT-MFS.21P................................ 1/37 1SVR740831R0300... CM-ESS.1P................................. 2/16 1SVR730712R1200... CM-MSS.41S.. ............................. 2/90 1SVR740010R3200... CT-MBS.22P. . .............................. 1/37 1SVR740831R0400... CM-ESS.2P................................. 2/16 1SVR730712R1300... CM-MSS.51S.. ............................. 2/90 1SVR740020R0200... CT-MVS.21P................................ 1/37 1SVR740831R1300... CM-ESS.1P................................. 2/16 1SVR730712R1400... CM-MSS.31S.. ............................. 2/90 1SVR740020R3100... CT-MVS.12P................................ 1/37 1SVR740831R1400... CM-ESS.2P................................. 2/16 1SVR730712R2200... CM-MSS.33S.. ............................. 2/90 1SVR740020R3300... CT-MVS.22P................................ 1/37 1SVR740840R0200... CM-SRS.11P............................... 2/15 1SVR730720R1400... CM-MSS.11S.. ............................. 2/90 1SVR740021R2300... CT-MVS.23P................................ 1/37 1SVR740840R0400... CM-SRS.21P............................... 2/15 1SVR730722R1400... CM-MSS.21S.. ............................. 2/90 1SVR740030R3300... CT-MXS.22P................................ 1/37 1SVR740840R0600... CM-SRS.M1P.............................. 2/15 1SVR730740R0100... CM-TCS.11S ............................ 2/104 1SVR740040R3300... CT-WBS.22P............................... 1/37 1SVR740841R0200... CM-SRS.11P............................... 2/15 1SVR730740R0200... CM-TCS.12S ............................ 2/104 1SVR740100R0300... CT-ERS.21P................................ 1/38 1SVR740841R0400... CM-SRS.21P............................... 2/15 1SVR730740R0300... CM-TCS.13S ............................ 2/104 1SVR740100R3100... CT-ERS.12P................................ 1/38 1SVR740841R1200... CM-SRS.11P............................... 2/15 1SVR730740R9100... CM-TCS.21S ............................ 2/104 1SVR740100R3300... CT-ERS.22P................................ 1/38 1SVR740841R1400... CM-SRS.21P............................... 2/15 1SVR730740R9200... CM-TCS.22S ............................ 2/104 1SVR740110R3300... CT-AHS.22P................................ 1/38 1SVR740884R1300... CM-MPS.31P.. ............................. 2/34 1SVR730740R9300... CM-TCS.23S ............................ 2/104 1SVR740120R3100... CT-ARS.11P................................ 1/38 1SVR740884R3300... CM-MPS.41P.. ............................. 2/34 1SVR730750R0400... CM-EFS.2S................................. 2/16 1SVR740120R3300... CT-ARS.21P................................ 1/38 1SVR740884R4300... CM-MPS.43P.. ............................. 2/34 1SVR730760R0400... CM-SFS.21S............................... 2/15 1SVR740180R0300... CT-APS.21P................................ 1/38 1SVR740885R1300... CM-MPS.11P.. ............................. 2/34 1SVR730760R0500... CM-SFS.22S............................... 2/15 1SVR740180R3100... CT-APS.12P................................ 1/38 1SVR740885R3300... CM-MPS.21P.. ............................. 2/34 1SVR730774R1300... CM-PAS.31S............................... 2/33 1SVR740180R3300... CT-APS.22P................................ 1/38 1SVR740885R4300... CM-MPS.23P.. ............................. 2/34 1SVR730774R3300... CM-PAS.41S............................... 2/33 1SVR740210R3300... CT-SDS.22P................................ 1/38 1SVR750005R0100... COV.12. . .................................... 2/130 1SVR730784R2300... CM-PSS.31S............................... 2/33 1SVR740211R2300... CT-SDS.23P................................ 1/38 1SVR750487R8300... CM-MPN.52S.............................. 2/34 1SVR730784R3300... CM-PSS.41S............................... 2/33 1SVR740660R0100... CM-IWS.1P.. ................................ 2/66 1SVR750488R8300... CM-MPN.62S.............................. 2/34 1SVR730794R1300... CM-PVS.31S............................... 2/33 1SVR740670R0200... CM-IWS.2P.. ................................ 2/66 1SVR750489R8300... CM-MPN.72S.............................. 2/34 1SVR730794R2300... CM-PVS.81S............................... 2/33 1SVR740700R0100... CM-MSS.12P.. ............................. 2/90 1SVR750660R0200... CM-IWN.1S................................. 2/66 1SVR730794R3300... CM-PVS.41S............................... 2/33 1SVR740700R0200... CM-MSS.22P.. ............................. 2/90 1SVR750660R0300... CM-IWN.4S................................. 2/66 1SVR730824R9300... CM-PFS.S .................................. 2/33 1SVR740700R2100... CM-MSS.13P.. ............................. 2/90 1SVR750660R0400... CM-IWN.5S................................. 2/66 1SVR730830R0300... CM-ESS.1S................................. 2/16 1SVR740700R2200... CM-MSS.23P.. ............................. 2/90 1SVR750660R0500... CM-IWN.6S................................. 2/66 1SVR730830R0400... CM-ESS.2S................................. 2/16 1SVR740712R0200... CM-MSS.32P.. ............................. 2/90 1SVR750669R9400... CM-IVN.S.................................... 2/66 1SVR730830R0500... CM-ESS.MS................................ 2/16 1SVR740712R1200... CM-MSS.41P.. ............................. 2/90 1SVR760487R8300... CM-MPN.52P.............................. 2/34 1SVR730831R0300... CM-ESS.1S................................. 2/16 1SVR740712R1300... CM-MSS.51P.. ............................. 2/90 1SVR760488R8300... CM-MPN.62P.............................. 2/34 2/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210 Index Numerical Order code Type Page 1SVR760489R8300... CM-MPN.72P.............................. 2/34 1SVR760660R0200... CM-IWN.1P................................. 2/66 1SVR760660R0300... CM-IWN.4P................................. 2/66 1SVR760660R0400... CM-IWN.5P................................. 2/66 1SVR760660R0500... CM-IWN.6P................................. 2/66 1SVR760669R9400... CM-IVN.P.................................... 2/66 2CDE 2CDE601101R2001... EPD24-TB-101-1A....................... 3/75 2CDE601101R2002... EPD24-TB-101-2A....................... 3/75 2CDE601101R2003... EPD24-TB-101-3A....................... 3/75 2CDE601101R2004... EPD24-TB-101-4A....................... 3/75 2CDE601101R2006... EPD24-TB-101-6A....................... 3/75 2CDE601101R2008... EPD24-TB-101-8A....................... 3/75 2CDE601101R2010... EPD24-TB-101-10A..................... 3/75 2CDE601101R2012... EPD24-TB-101-12A..................... 3/75 2CDE601101R2905... EPD24-TB-101-0.5A.................... 3/75 7 2CDE605100R0500... EPD-BB500................................. 3/75 2CDE605200R0021... EPD-SB21................................... 3/75 GJD GJD6155620R0087. .. SK 615 562-87............................ 1/39 GJD6155620R0088. .. SK 615 562-88............................ 1/39 2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/12 ABB STOTZ-KONTAKT GmbH You can find the address of your local sales organisation on the ABB homepage: www.abb.com/contacts > Low Voltage Products and Systems Find out more about Electronic Products and Relays on: http://new.abb.com/low-voltage/products/epr Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG. Copyright © 2015 ABB All rights reserved DE ABB 2CDC 110 004 C0210 Rev A printed in Federal Republic of Germany (03/2015) Contact us
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2015:03:16 14:33:24+01:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2015:03:16 14:40:04+01:00 Title : Trapped : False Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2015:03:16 14:40:04+01:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Document ID : uuid:1e8fba64-0a40-4007-be56-d8ab22beae01 Instance ID : uuid:531a8095-3b90-45b4-a074-01e5ce8cabaa Producer : Adobe PDF Library 10.0.1 Page Count : 424EXIF Metadata provided by EXIF.tools