Brochure

2016-10-06

: Pdf 145613-Brochure 145613-Brochure B5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 424

DownloadBrochure
Open PDF In BrowserView PDF
Catalog | March 2015

Catalog 2015
Electronic Products and Relays

2 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Machine Safety
Jokab Safety products

Productivity and safety go hand in hand
Jokab Safety was acquired by ABB in 2010. This gives us extra strength and a sales network in 120 countries. Our goal is to become
even better at supporting you as a customer through cooperation within ABB Jokab Safety globally and locally. The fact that the leading
power and automation technology company, ABB, and a leader in machine safety, Jokab Safety, have joined forces means a lot more
than just a new organizational chart. ABB has a huge footprint in the industry - from power supply to the control of each individual motor
- and has been delivering reliable solutions for decades that boost productivity in the industry. The acquisition of Jokab Safety means
the last building block is in place. We can now offer our customers tailored, turnkey solutions where machine safety is an integral and
value-enhancing component.
Jokab Safety offering:
–– Safety PLC
Pluto, Pluto AS-i, Gateways, Safe Encoder
–– Safety controller
Vital and Tina safety systems
–– Safety relays
RT series, JSB series, safety timers, expansion relays
–– Light curtains, light grids, light beams and scanner
Focus II, Spot, Look
–– Sensors, switches and locks
Eden, Sense, MKey, Magne, Dalton, Knox
–– Control devices
JSHD4, Safeball, Fox2
–– Emergency stop devices
Inca, Smile, EStrong, LineStrong
–– Contact rails, bumpers and safety mats
–– Fencing systems
Quick-Guard, SafeCad, Roller doors

Further information: „ABB Safety Handbook“ - Order code: 2TLC172001C0202
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

3

Electronic Products and Relays
News
Thermistor motor protection relays in new housing
The thermistor motor protection relays of the CM-MSS range monitor the winding temperature
of motors which have PTC temperature sensors installed. These sensors are incorporated in
the motor windings thus measuring the motor heat directly. This direct temperature measurement enables the thermistor motor protection relays to evaluate various motor conditions such
as overheating, overload and insufficient cooling. Depending on the product also the ATEX
approval is available for the use in hazardous areas.
The new housing provides two different connection terminals: The proven double-chamber
cage connection terminals and the Easy Connect Technology with Push-in terminals.

CR-S Range pluggable small interface relays
The pluggable interface relays of the CR-S Range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems
and the sensor / actuator level. The CR-S Range combines the flexibility of a modular system
and the ability of switching high currents on a small footprint thus can be used in applications
where space saving is essential.

Universal Motor Controller UMC100.3 now available
The intelligent ABB Motor Controllers for motor protection, motor control, fieldbus and Ethernet communication and fault diagnosis. Due to the benefits it provides, the UMC is used
worldwide in many segments and in Projects with several thousand motor controllers. Beside
the proven UMC100 the new UMC100.3 offers even more capabilities like 24 V DC or
110-220 V AC/DC supply voltage and fieldbus communication interfaces.

Grid feeding monitoring relays from the CM-UFD.Mx range
The multifunctional grid feeding monitoring relays of the CM-UFD range are designed to monitor several grid parameters when feeding energy into the public grid. The intention is to trip a
section switch which is connected between the distributed generation and the public grid in
order to disconnect the distributed generation in case of problems (e.g. unstable grid), faults or
maintenance on the grid. Different monitoring functions such as 10-minutes average value, real
time over- and undervoltage as well as over- and underfrequency are configurable via the front
face display.
–– CM-UFD.M22: Third party certificate confirming accordance with CEI 0-21: 2012-06 + CEI
0-21; V1: 2012-12 + A70 Terna
–– CM-UFD.M31: Third party certificate confirming accordance with VDE-AR-N 4105: 2011-08;
BDEW, June 2008 “Technische Richtlinie – Erzeugungsanlagen am Mittelspannungsnetz”
including supplementary provisions of January 2013
–– CM-UFD.M33: Factory certificate confirming accordance with Engineering Recommendation
G59 Issue 3 - September 2013; Engineering Recommendation G83 Issue 2 - December 2012

4 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Electronic Products and Relays
Table of contents
Electronic timers

1/1

Measuring and monitoring relays

2/1

Primary switch mode power supplies

3/1

Analog signal converters, serial data converters

4/1

Interface relays and optocouplers

5/1

Logic relays

6/1

Index

7/1

1
2
3
4
5
6
7

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

5

Approvals and marks for the world market
Overview
ABB low-voltage switching devices are developed and produced in accordance with the applicable regulations as stated in the international IEC publications, the European EN specifications and the national VDE standards.
In most countries, low-voltage switching devices are produced according to such regulations under the responsibility of the manufacturers. This is why the
devices are not subject to further approval. However, for those devices which are intended for use in household or for public use our customers can request test reports of our internal laboratory for presentation to the various qualified local organizations. In other countries, approvals are prescribed by law.
For devices installed in ships, an approval issued by independent shipping companies, such as the GL, are demanded by the maritime insurance
companies.

Marks of conformity and examples of approvals (device-dependent)
Berufsgenossenschaft
der Feinmechanik und
Elektrotechnik (BGFE)

International
CB scheme

K

The CB (Certification Body) Scheme is a
system designed to facilitate international
trade by establishing mutual acceptance
of test reports among participating safety
certification organizations (the National Certification Bodies) in more than 30 ­countries.
The CB Scheme was e
­ stablished by the
International
Electrotechnical Committee for Conformity
Testing to Standards for Electrical
Equipment (IECEE).

The BG-PRÜFZERT sign is a voluntary
­safety mark, awarded by the BGFE ­following
successful safety testing.
Explosion protection (EX)

Conformité Européen (CE)

Swiss insurance institution
(SUVA)

Q

Department accident prevention suvaPRO

C

Shipping approval

a

All devices which comply with the ­European
low voltage directive and which are intended
for sale within the European Union must
have the CE sign applied. All products in this
catalog are CE marked.
The CE sign must not be confused with a
certificate of quality issued by the EU. It is
solely used to confirm that the respective
product complies with the applicable
European directives *). The CE sign is part
of an administrative procedure to ­guarantee
free movement of goods within the European Community.
*) Directives:
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Machinery Directive 98/37/EEC
Verband der Elektrotechnik
Elektronik Informationstechnik
(VDE)

I

Explosion protection acc. to
Directive 94/9/EG (ATEX 100a)

Germanischer Lloyd (GL)

Europe

M

Lloyds Register

P

Shipping approval

In Russia, low-voltage switching devices are
subject to certification and have to be provided with a sign.

R

EAC certification is mandatory for many products. This certification is based on a safety
test (IEC standards with Russiaspecific deviations) and an EMC test.
Russian Maritime Register of
Shipping RMRS

L

Shipping approval

J

Applicable for technical instruments ­covered
by the German Gerätesicherheitsgesetz
(GSG) as well as for single parts and electrical wiring devices.

Australia, New Zealand
C-Tick Mark

b

E

In China the CCC certification mark is a
compulsory certification mark in the field of
safety and quality for products sold on the
Chinese market.

North America
Canadian and US standards are more or
less equivalent but considerably differ from
the IEC and VDE regulations.
USA
Underwriters Laboratories (UL)
Listing

B

Released for installation in systems and for
sale as individual component in the USA.

G

Released for installation in systems, if the
respective system has been completely
mounted and wired by qualified personnel.
Canada
Canadian Standards
Association (CSA)

F

USA and Canada
The combined UL signs for the USA and
Canada are recognized by the ­authorities of
both countries. Devices with this ­certificate
meet the requirements of both countries.
Listing

The C-Tick Mark certifies compliance with
the Australian EMC requirements. The Mark
is also recognized in New Zealand.

6 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CCC (China Compulsory
Certification)

Recognition

Russia

Eurasian Conformity

China

Recognition

A
H

Find Electronic Products and Relays product information and
documentation on our web page
The following steps will guide you to the documentation and product search section of the Electronic Products and Relays portfolio on www.ABB.com.

Enter http://new.abb.com/low-voltage/products/epr in your internet browser.
You will be redirected to the following page:

Latest information about the Electronic Products and Relays product range could be found in the Highlights section.
In the lower area of the web page you can find the Our offering section.
The assortment of the Electronic Products and Relays range is listed here as shown in the screenshot below:

Select the register of the relevant product group to see all the products related to the product group.
Choose a product range from which you want to see the documentation or from which you want to choose a specific product.
In this example the CT-S range from the register Electronic timers has been selected as shown on the screenshot.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

7

Find Electronic Products and Relays product information and
documentation on our web page
You will be redirected to the following page:

Latest information about the Electronic Products and Relays product range could be found in the Highlights sections.
In the lower area of the web page you can find the Products and documents section.
The functions to choose a product or a document are listed here as in the screenshot below:

To search for a product continue on page 9.
To search for documentation continue on page 10.

8 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Find Electronic Products and Relays product information and
documentation on our web page
How to find the right product
Click on Filters to see the different search attributes for the selected product range.
The filter section will be expanded as shown below.

The different product filters are shown.
Click on the filter attribute to continue the product search process.
In this example Output has been chosen.

In the right part mark the corresponding check box to narrow down the search. You can also select several check boxes.
Click on Apply to submit your filter.
The search results are now listed according to your selection.
Proceed this approach with different filters until the right product is listed.
Click on the product in the Result section to get the dedicated product information listed in your browser.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

9

Find Electronic Products and Relays product information and
documentation on our web page
How to find the right documentation
Click on Documents to see the different types of documentation for the product.
The document section will be expanded as shown below.

On the left side select the type of document related to the product. In the example Popular documents has been selected.
In the right area click on the document related to the product.
The document is opened or downloaded, depending on the individual browser settings.

10 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

EPR Catalog 2015
Notes

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

11

Electronic timers
Product group picture
1

1/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Electronic timers
Table of contents
Electronic timers
Table of contents

1/2

Overview

1/3

Approvals and marks

1/4

CT-D range

1/5

Table of contents

1/6

Benefits and advantages

1/7

Ordering details

1/8

Function diagrams

1/9

Connection diagrams

1/12

Technical data

1/13

Technical data, Technical diagrams

1/15

Wiring notes, Dimensional drawings

1/16

CT-E range

1/17

Table of contents

1/18

Benefits and advantages

1/19

Ordering details

1/20

Function diagrams

1/22

Connection diagrams

1/27

Connection diagrams, Technical diagrams

1/28

Technical data

1/29

Wiring notes, Dimensional drawings

1/31

CT-S range

1/33

Table of contents

1/34

Benefits and advantages

1/35

Ordering details - multifunctional

1/37

Ordering details - singlefunctional

1/38

Ordering details - Accessories

1/39

Function diagrams

1/41

Connection diagrams

1/49

Technical data

1/52

Technical diagrams

1/55

Wiring notes, Dimensional drawings

1/56

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/2

1

Electronic timers
Overview
1

CT-D range
Timing function

multifunctional

CT-E range

single-functional

multifunctional

single-functional

CT-S range
multifunctional

single-functional

A

ON-delay

CT-MFD

CT-ERD

CT-MFE,
CT-MKE

CT-ERE,
CT-EKE

CT-MVS, CT-MFS,
CT-MBS, CT-WBS

CT-ERS

B

OFF-delay

CT-MFD

CT-AHD

CT-MFE

CT-AHE,
CT-ARE,
CT-AKE

CT-MVS, CT-MFS,
CT-MBS

CT-APS,
CT-AHS,
CT-ARS

AB ON- and OFF-delay
CA Impulse-ON

CT-MFD

CB Impulse-OFF

CT-MFD

CE Impulse-ON and OFF
DA Flasher starting with ON

CT-MFD

DB Flasher staring with OFF

CT-MFD

DE

Flasher starting with ON or
OFF

ED

Pulse generator starting with
ON or OFF

H

Pulse former

F

Star-delta change-over

CT-VWD

CT-MFE,
CT-MKE

CT-VWE
CT-AWE

CT-EBD

CT-MFE,
CT-MKE
CT-MFE,
CT-MKE

CT-EBE

CT-TGD
CT-MFD

CT-MVS, CT-MXS,
CT-MFS, CT-MBS
CT-MVS, CT-MFS,
CT-MBS, CT-WBS
CT-MVS, CT-MFS,
CT-MBS
CT-MXS
CT-MFS, CT-MBS,
CT-WBS
CT-MFS, CT-MBS,
CT-WBS
CT-MVS
CT-MXS

CT-MFE

CT-MVS, CT-MFS,
CT-MBS

CT-SDD,
CT-SAD

CT-SDS
CT-SDE

FC Star-delta change-over with
impulse

CT-MVS.2x,
CT-MFS, CT-MBS

CT-YDE

FA Star-delta change-over
twice ON-delayed

A+

AC

BC

CT-MVS, CT-MXS,
CT-MFS, CT-MBS,
CT-WBS

G

further functions
(depending on device)

Technical data (extract)
Time ranges

7 (0.05 s - 100 h)
CT-SDD, CT-SAD:
4 (0.05 s - 10 min)

Multifunction devices:
8 (0.05 s - 100 h)
Single-function devices:
5 single ranges (0.05-1 s, 0.1-10 s,
0.3-30 s, 3-300 s, 0.3-300 min)

10 (0.05 s - 300 h)
CT-ARS, CT-SDS:
7 (0.05 s- 10 min)

Control supply voltage

Wide and multi ranges

Wide ranges

Wide, multi and single ranges

Type and number of contacts

1 or 2 c/o contacts
CT-SDD, CT-SAD: 2 n/o contacts

1 c/ o contact
CT-SDE: 1 n/o contact and 1 n/c
contact
CT-MKE, CT-EKE, CT-AKE: 1 thyristor

1 or 2 c/o contacts
CT-MVS.21, CT-MFS, CT-MBS:
2nd c/o contact selectable as inst.
contact
CT-SDS: 2 n/o contacts

Control inputs

voltage-related triggering,
polarized, capable of switching a
parallel load

voltage-related triggering, polarized
CT-MFE, CT-AHE, CT-AWE:
with auxiliary voltage

voltage-related triggering, nonpolarized, capable of switching a
parallel load
CT-MFS, CT-MBS, CT-AHS:
volt-free triggering

1/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Single and dual
ranges

Electronic timers
Approvals and marks
CT-D

J

J

J

J

J

J

J

J

J

J

CT-SAD.22

J

CT-SDD.22

CT-AHD.12

J

J

CT-TGD.22

CT-ERD .22

J

CB scheme

CT-EBD.12

CT-ERD.12

UL 508, CAN/CSA C22.2 No.14

K

CT-VWD.12

CT-MFD.21

A

Approvals

1

CT-AHD.22

CT-MFD.12

existing
pending

CT-TGD.12

J
j

J

J

J

J

EAC

J

J

J

J

J

J

J

J

J

J

J

J

E

CCC

J

J

J

J

J

J

J

J

J

J

J

J

L

RMRS

J

J

J

J

J

J

J

J

J

J

a

CE

J

J

J

J

J

J

J

J

J

J

J

J

b

C-Tick

J

j

J

j

J

j

J

J

J

j

j

j

Marks

CT-E

CT-MFE

CT-ERE

CT-AHE

CT-ARE

CT-VWE

CT-AWE

CT-EBE

CT-YDE

CT-SDE

CT-MKE

CT-EKE

CT-AKE

J existing
j pending

A

UL 508, CAN/CSA C22.2 No.14

J

J

J

J

J

J

J

J

J

J

J

J

C

GL

J

J

J

J

J

J

J

J

J

J

J

J

K

CB scheme

J

J

J

J

J

J

J

J

J
J

J

J

Approvals

EAC

J

J

J

J

J

J

J

J

J

E

CCC

J

J

J

J

J

J

J

J

J

L

RMRS

J

J

J

J

J

J

J

J

J

J

J

J

a

CE

J

J

J

J

J

J

J

J

J

J

J

J

b

C-Tick

J

J

J

J

J

J

J

J

J

J

J

J

Marks

CT-S

CT-MVS.12S/P

CT-MVS.2xS/P

CT-MXS.22S/P

CT-MFS.21S/P

CT-MBS.22S/P

CT-WBS.22S/P

CT-ERS.12S/P

CT-ERS.2xS/P

CT-APS.12S/P

CT-APS.2xS/P

CT-AHS.22S/P

CT-ARS.11S/P

CT-ARS.21S/P

CT-SDS.2xS/P

J existing
j pending

A

UL 508, CAN/CSA C22.2 No.14

J

J

J

J

J

J

J

J

J

J

J

J

J

J

C

GL

J

J

J

J

J

J

J

J

J

J

J

j

j

J

EAC

J

J

J

J

J

J

J

J

J

J

J

J

J

J

K

CB scheme

J

J

J

J

J

J

J

J

J

J

J

J

J

J

E

CCC

J

J

J

J

J

J

J

J

J

J

J

J

J

J

L

RMRS

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

Approvals

Rail applications

1)

J

J

J

Marks
a

CE

J

J

J

J

J

J

J

J

J

J

J

J

J

J

b

C-Tick

J

J

J

J

J

J

J

J

J

J

J

J

J

J

1)

Applicable in rail application following the latest standards for rail applications. Further information are available in our rail segment brochure 2CDC110084B0201.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/4

CT-D range
Product group picture
1

1/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CT-D range
Table of contents
CT-D Range
Benefits and advantages

1/7

Ordering details

1/8

Function diagrams

1/9

Connection diagrams

1/12

Technical data

1/13

Technical data, Technical diagrams

1/15

Wiring notes, Dimensional drawings

1/16

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/6

1

CT-D range
Benefits and advantages
Characteristics
–– Diversity:
–– 2 multifunction timers
–– 10 single-function timers
–– Control supply voltages:
–– Wide range: 12-240 V AC/DC
–– Multi range: 24-48 V DC, 24-240 V AC
–– 7 time ranges from 0.05 s to 100 h or
4 time ranges from 0.05 s to 10 min
–– Width of only 17.5 mm
–– Light-grey housing in RAL 7035
–– Devices with:
1 c/o contact (250 V / 6 A) or 2 c/o contacts (250 V / 5 A)
Control input: voltage-related triggering, polarized, 		
capable of switching parallel loads
–– Approvals / Marks (partly pending, details see page 1/4)

–– A, K1), E,
1)

Benefits
Direct reading scales 1
Direct setting of the time delay without any additional
calculation provides accurate time delay adjustment.
LEDs for status indication 2
All actual operational states are displayed by front-face LEDs,
thus simplifying commissioning and troubleshooting.
Switching currents
The CT-D range timers allow an output load of up to 6 A on
devices with 1 c/o contact and up to 5 A on devices with
2 c/o contacts.
Connection terminals 3
Wide terminal spacing allows connection of wires:
2 x 1.5 mm² (2 x 16 AWG) with wire end ferrules or 2 x 2.5
mm² (2 x 14 AWG) without ferrules.

, L / a, b

Only for devices with 1 c/o (SPDT) contact

4
Width 17.5 mm
With their width of 17.5 mm only, the CT-D range timers are
ideally suited for installation in distribution panels.

Operating controls
1 LEDs for status indication
U - green LED: V control supply voltage applied
W timing
R, R1, R2 - yellow LED: V output relay energized

3
2

2 Time range adjustment
3 Fine adjustment of the time delay

1

4 Preselection of the timing function

3

4
2

3

2CDC 253 021 F0004

2

2CDC 253 033 F0004

1

2CDC 253 132 F0006

single-functional

multifunctional

2CDC 253 066 F0006

1

4

17.5 mm

1/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CT-D range
Ordering details
Description
The CT-D range in MDRC design with a width of only 17.5 mm fits into all domestic installation
and distribution panels.
The CT-D range represents a link between industry and the installation types. For maximum
flexibility in operation, 10 single-function as well as 2 multifunction devices with 7 timing
functions are available. The devices offer 4 or 7 time ranges from 0.05 seconds up to 100
hours. Their wide input range allows the use in applications worldwide.

Ordering details

2CDC 251 089 F0006

Timing
function

Rated
control
supply
voltage

Time ranges Control
input

Multifunctional1)

24-240 V AC
24-48 V DC

7 (0.05 s 100 h)

M

1 c/o

CT-MFD.12

1SVR500020R0000

0.060
(0.132)

Multifunctional1)

12-240
V AC/DC

7 (0.05 s 100 h)

M

2 c/o

CT-MFD.21

1SVR500020R1100

0.065
(0.143)

-

1 c/o

CT-ERD.12

1SVR500100R0000

0.060
(0.132)

-

2 c/o

CT-ERD.22

1SVR500100R0100

0.065
(0.143)

M

1 c/o

CT-AHD.12

1SVR500110R0000

0.060
(0.132)

M

2 c/o

CT-AHD.22

1SVR500110R0100

0.065
(0.143)

CT-VWD.12

1SVR500130R0000

OFF-delay
ImpulseON

2CDC 251 091 F0006

Flasher
starting
with ON

7 (0.05 s 100 h)

-

24-240 V AC
24-48 V DC

-

Pulse
generator

2×7 (0.05 s 100 h)

Star-delta
changeover

4 (0.05 s 10 min)

1)

2)
3)
4)

A
ON-delay
B
OFF-delay
CA Impulse-ON
CB Impulse-OFF
DA Flasher starting with ON
DB Flasher staring with OFF
H
Pulse former
ED Pulse generator
F
Star-delta change-over

Type

Order code

Price

Weight
(1 pce)

1 pce

kg (lb)

ON-delay

CT-MFD.12

CT-ERD.22

Output

1 c/o

M
M
-

2 c/o
2 c/o

0.060
(0.132)

CT-EBD.12

1SVR500150R0000

CT-TGD.122)

1SVR500160R0000

0.060
(0.132)

CT-TGD.222)

1SVR500160R0100

0.065
(0.143)

CT-SDD.223)

1SVR500211R0100

CT-SAD.22

1SVR500210R0100

4)

0.065
(0.143)

Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage,
Flasher starting with ON, Flasher starting with OFF, Pulse former
ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h
M Control input with voltage-related triggering
Transition time 50 ms fixed
- no triggering
Transition time adjustable

Synonyms
used expression

alternative expression(s)

used expression

alternative expression(s)

1 c/o contact

SPDT

voltage-related

wet / non-floating

2 c/o contacts

DPDT

volt-free

dry / floating

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/8

1

CT-D range
Function diagrams
Remarks
Legend

Function of the yellow LED
The yellow LED R glows as soon as the output relay
energizes and turns off when the output relay de-energizes.

G		
B		

Control supply voltage not applied / Output contact open
Control supply voltage applied / Output contact closed
A1-Y1/B1 Control input with voltage-related triggering

Terminal designations on the device and in the diagrams
The 1st c/o contact is always designated 15-16/18.
The 2nd c/o contact is designated 25-26/28.
The n/o contacts of the star-delta timers are designated with
17-18 and 17-28.
Control supply voltage is always applied to terminals A1-A2.

ON-delay (Delay on make)
CT-ERD, CT-MFD

B

A1-A2
15-18, 25-28
15-16, 25-26
green LED
t

 10 % of the minimum rated control supply voltage U s

Input circuit - Control circuit
Control input, control function
A1-Y1/B1
Kind of triggering
Resistance to reverse polarity
Parallel load / polarized
Maximum cable length to the control inputs
Minimum control pulse length
Control voltage potential
Current consumption of the control input
Timing circuit
Time ranges
7 time ranges 0.05 s - 100 h
4 time ranges 0.05 s - 10 min (CT-SDD, CT-SAD)
Recovery time
Accuracy within the rated control supply voltage tolerance
Accuracy within the temperature range
Repeat accuracy (constant parameters)
Setting accuracy of time delay
IEC/EN 61812-1
Star-delta transition time
CT-SDD / CT-SAD
Star-delta transition time tolerance
Indication of operational states
Control supply voltage / timing

CT-SDD / CT-SAD

12-240 V AC/DC

start timing external
voltage-related triggering
yes
yes / yes
50 m ‑ 100 pF/m
20 ms
see rated control supply voltage
see data sheet
1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min
5.) 5-100 min 6.) 0.5-10 h 7.) 5-100 h
1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min
< 50 ms
it < 0.005 % / V
it < 0.06 % / °C
it < ± 0.5 %
± 10% of full-scale value
fixed 50 ms /
adjustable: 20 ms, 30 ms, 40 ms, 50 ms, 60 ms, 80 ms or 100 ms
±3 ms

U: green LED V : control supply voltage applied
W : timing
R: yellow LED V : output relay energized

Relay energized (1 c/o contact /
2 c/o contacts or inst. contact)
Operating elements and controls
Adjustment of the time range
Fine adjustment of the time value
Preselection of the timing function at multifunction devices
Adjustment of the transition time
CT-SAD
Output circuit
Kind of output
15-16/18
15-16/18; 25-26/28
17-18; 17-28
Contact material
Rated operational voltage U e
Minimum switching voltage / minimum switching current
Maximum switching voltage / maximum switching current
Rated operational current I e
AC-12 (resistive) at 230 V
(IEC/EN 60947-5-1 )
AC-15 (inductive) at 230 V
DC-12 (resistive) at 24 V
DC-13 (inductive) at 24 V
AC rating (UL 508)
utilization category (Control Circuit Rating Code)
max. rated operational voltage
Maximum continuous thermal current at B300
Maximum continuous thermal current at C300
max. making/breaking apparent power at B300
max. making/breaking apparent power at C300
Mechanical lifetime
Electrical lifetime
Max. fuse rating to achieve short-circuit protection
n/c contact
(IEC/EN 60947-5-1)
n/o contact

1/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

front-face
front-face
front-face
front-face

rotary switch, direct reading scales
potentiometer
rotary switch, direct reading scales
potentiometer

Relay, 1 c/o contact
AgNi alloy, Cd free
250 V

Relay, 2 c/o contacts
Relay, 2 n/o contacts (CT-SDD, CT-SAD)

12 V / 100 mA
250 V AC / 6 A
250 V AC / 5 A
6A
5A
3A
3A
6A
5A
2A
2A
B 300
300 V AC
5A
3600 VA / 360 VA
30 x 10 6 switching cycles
0.1 x 10 6 switching cycles
6 A fast-acting
10 A fast-acting

n/o: 3 A n/c: 0.75 A
1A
n/o: B 300 n/c: C 300
n/o:
n/c:
n/o:
n/c:

5A
2.5 A
3600/360 VA
1800/180 VA

6 A fast-acting

CT-D range
Technical data

CT-D with 1 c/o
contact

CT-D with 2 c/o
contacts

CT-MFD.21

General data
Mean time between failures (MTBF)
Duty time
Dimensions (W x H x D)
Weight
Mounting
Mounting position
Minimum distance to other units
Degree of protection
Electrical connection
Wire size

Stripping length
Tightening torque
Environmental data
Ambient temperature range
Climatic class
Relative humidity range
Shock (half-sine)
Isolation data
Rated impulse withstand voltage U imp
between all isolated circuits
Pollution category
Overvoltage category
Rated insulation voltage U i

on request
100%
17.5 x 70 x 58 mm
17.5 x 80 x 58 mm
(0.69 x 2.76 x 2.28 in) (0.69 x 3.15 x 2.28 in)
see ordering details
DIN rail (IEC/EN 60715), snap-mounting without any tool
any
horizontal / vertical no / no
housing / terminals IP50 / IP20
fine-strand with(out) wire end ferrule 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
1 x 0.5-2.5 mm 2 (1 x 20-14 AWG)
rigid 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
1 x 0.5-4 mm 2 (1 x 20-12 AWG)
7 mm (0.28 in)
0.5-0.8 Nm (4.43-7.08 lb.in)
operation / storage -20 ... +60 °C / -40 ... +85 °C
IEC/EN 60068-2-30 3K3
25-85%
IEC/EN 60068-2-27 150 m/s 2, 11 ms
IEC/EN 60664-1 type test: 4 kV; 1.2/50 µs
IEC/EN 60664-1
IEC/EN 60664-1
input circuit / output circuit
output circuit 1 / output circuit 2
input circuit / output circuit
input circuit / output circuit

Basic insulation (IEC/EN 61140)
Protective separation
(IEC/EN 61140, EN 50178)
Power-frequency withstand voltage test
between all isolated circuits
(test voltage)
Standards
Product standard
Low Voltage Directive
EMC Directive
RoHS Directive
Electromagnetic compatibility
Interference immunity to
electrostatic discharge
IEC/EN 61000-4-2
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3
electrical fast transient / burst
IEC/EN 61000-4-4
surge
IEC/EN 61000-4-5
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6
Interference emission
high-frequency radiated
IEC/CISPR 22, EN 55022
high-frequency conducted
IEC/CISPR 22, EN 55022

„Approvals and marks“ see page 1/4.

3
III
300 V
not available
300 V
250 V

300 V

300 V

routine test: 2.5 kV; 50 Hz; 1 s
type test: 2.5 kV; 50 Hz; 60 s
IEC/EN 61812-1
2006/95/EC
2004/108/EC
2011/65/EC
IEC/EN 61000-6-1, IEC/EN 61000-6-2
Level 3 (6 kV / 8 kV)
Level 3 (10 V / m)
Level 3 (2 kV / 5 kHz)
Level 4 (2 kV L-L)
Level 3 (10 V)
IEC/EN 61000-6-3, IEC/EN 61000-6-4
Class B
Class B

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/14

1

CT-D range
Technical data, Technical diagrams
Technical diagrams
Load limit curves

resistive load

AC current [A]

DC current [A]

resistive load

AC current [A]

2CDC 252 121 F0206

AC voltage [V]

resistive load

DC voltage [V]

CT-D.1x

2CDC 252 122 F0206

CT-D.1x

DC current [A]

CT-D.2x

CT-D.2x

2CDC 252 124 F0206

1.0
0.9
0.8
0.7

250 V
resistive load

0.6
0.5

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9 1.0
cos ϕ

1/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Switching current [A]

2CDC 252 123 F0206

Contact lifetime

Switching cycles

Derating factor F
for inductive AC load

0.1

2CDC 252 045 F0207

AC voltage [V]

resistive load

DC voltage [V]

DC load (resistive)

2CDC 252 044 F0207

AC load (resistive)

Derating factor F

1

CT-D range
Wiring notes, Dimensional drawings
Wiring notes for devices with control input
A parallel load to the control input is possible

A1

2CDC 252 102 F0b06

L(+)

1

Y1/B1

A2

N(-)

dimensions in mm

Dimensional drawings

CT-D devices with 1 c/o contact or 2 n/o contacts

58 2.28“
43,4 1.71“

80 3.15“

0.2“
5

45 1.77“

0.69“
17,5

2CDC 252 130 F0b06

58 2.28“
43,4 1.71“

45 1.77“

70 2.76“

0.2“
5

2CDC 252 131 F0b06

0.69“
17,5

CT-D devices with 2 c/o contacts

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/16

CT-E range
Product group picture
1

1/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CT-E range
Table of contents
CT-E Range
Product group picture

1/17

Table of contents

1/18

Benefits and advantages

1/19

Ordering details

1/20

Function diagrams

1/22

Connection diagrams

1/27

Connection diagrams, Technical diagrams

1/28

Technical data

1/29

Wiring notes, Dimensional drawings

1/31

Notes

1/32

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/18

1

CT-E range
Benefits and advantages
Characteristics
–– Diversity:
–– 2 multifunction timers
–– 56 single-function timers
–– Control supply voltages:
–– Dual range: 24 V AC/DC
–– Single range: 110-130 V AC, 220-240 V AC
–– Wide range: 24-240 V AC/DC (CT-MFE)
–– Time ranges
–– 5 single ranges: 0.05-1 s, 0.1-10 s, 0.3-30 s, 3-300 s,
0.3-30 min
–– 8 time ranges: 0.05 s - 100 h (CT-MFE)
–– Devices with 1 c/o (SPDT) contact (250 V / 4 A) or
solid-state output for high switching frequencies (thyristor
0.8 A)
–– Approvals / Marks (details see page 1/4)
–– A, C,

Benefits
1
Direct reading scales
Direct setting of the time delay without any additional
calculation provides accurate time delay adjustment.

LEDs for status indication 2
All actual operational states are displayed by front-face LEDs,
thus simplifying commissioning and troubleshooting.
Connection screws in M3 (Pozidrive 1) 3
Easy and fast tightening and release of the connection screws
with pozidrive, pan- or crosshead screwdriver.
4
Solid-state output
Devices with solid-state output are the perfect solution for
high operation cycles.

R, K, E, L / a, b

Synonyms
used expression

alternative expression(s)

used expression

alternative expression(s)

1 c/o contact

SPDT

voltage-related

wet / non-floating

2 c/o contacts

DPDT

volt-free

dry / floating

Operating controls

1
2
3

1 LEDs for status indication
U - green LED: V control supply voltage applied
R2: red LED: V output relay energized
2 Time range adjustment (only multifunctional devices)
3 Fine adjustment of the time delay
4 Preselection of the timing function (only multifunctional devices)

4

A1

AL
A1

AL

1/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

2CDC 252 166 F0005

3

2CDC 252 166 F0005

2

1SVC 110 000 F0506

1

1SVC 110 000 F0500

4

1SVC 110 000 F0508

1

CT-E range
Ordering details
Description
The CT-E range with its excellent price/performance ratio offers an ideal solution for serial
applications. 56 single-function devices with 5 different time ranges as well as 2 multifunction
timers with 6 functions and 8 time ranges offer the highest possible flexibility for almost every
application. For high operating cycles, contact-free CT-E timers with solid-state output are
available.

Ordering details
Timing
function
Multifunctional 1)

Rated control supply
voltage
24-240 V AC/DC

Time
ranges
8 (0.05 s 100 h)

Control
Input

Output

M

1 c/o

Type

1SVR 550 029 F8100

24 V AC/DC,
220-240 V AC

CT-MFE

24 V AC/DC

0.3-30 s
3-300 s

1SVR550107R2100
1 c/o

CT-ERE

1SVR 550 111 F1100

110-130 V AC

220-240 V AC

CT-AHE

24 V AC/DC,
220-240 V AC
OFF-delay2)
110-130 V AC

A
ON-delay
B
OFF-delay
CA Impulse-ON
CB Impulse-OFF
DA Flasher starting with ON
DB Flasher staring with OFF
H
Pulse former

24 V AC/DC,
220-240 V AC

0.1-10 s

1SVR550118R1100

0.3-30 s

1SVR550118R4100

3-300 s

1SVR550118R2100

0.3-30 s

1SVR550110R1100
M

1 c/o

CT-AHE

1SVR550110R2100

0.1-10 s

1SVR550111R1100

0.3-30 s

1SVR550111R4100

3-300 s

1SVR550111R2100

0.1-10 s

1SVR550127R1100

0.1-10 s

-

1 c/o

CT-ARE

110-130 V AC
220-240 V AC

1SVR550127R4100
1SVR550120R1100

0.3-30 s

1SVR550120R4100

0.1-10 s

1SVR550137R1100

0.3-30 s

1SVR550137R4100
-

1 c/o

CT-VWE

1SVR550137R2100
1SVR550130R1100

0.3-30 s

1SVR550130R4100

3-300 s

1SVR550130R2100

24 V AC/DC
ImpulseOFF2)

1SVR550110R4100

3-300 s

0.3-30 s

0.08 (0.18)

1SVR550100R2100
1SVR550100R5100

0.1-10 s
110-130 V AC

1SVR550100R1100

0.3-30 min

3-300 s

Impulse-ON

1SVR550107R5100

1SVR550100R4100

-

0.1-10 s
OFF-delay

0.08 (0.18)

1SVR550107R4100

-

0.1-10 s
110-130 V AC

1SVR550029R8100

Weight
(1 pce)
kg (lb)

1SVR550107R1100

0.3-30 min

ON-delay

CT-MFE

3-300 s

Price
1 pce

0.1-10 s
0.3-30 s

Order code

0.08 (0.18)

0.08 (0.18)

0.08 (0.18)

1SVR550158R3100
0.05-1 s

-

1 c/o

CT-AWE

1SVR550150R3100

0.08 (0.18)

1SVR550151R3100

1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Flasher starting with ON, Flasher starting with OFF,
Pulse former
2) without auxiliary voltage, True Off-delay timer

M Control input with voltage-related triggering
- no triggering

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/20

1

CT-E range
Ordering details
Bestellangaben

1

Timing
function

Rated control supplyvoltage

2CDC 251 125 F0004

24 V AC/DC

ImpulseOFF

CT-AWE

110-130 V AC

220-240 V AC

2CDC 251 059 F0003

Flasher
staring with
OFF

CT-SDE

Star-delta
changeover twice
ON-delayed

24 V AC/DC,
220-240 V AC

Time
ranges

Control
Input

Output Type

0.1-10 s
0.3-30 s

1SVR550148R1100
1SVR550148R4100

3-300 s

1SVR550148R2100

0.1-10 s
0.3-30 s

1 c/o

CT-AWE

1SVR550140R2100

0.1-10 s
0.3-30 s

1SVR550141R1100

3-300 s

1SVR550141R2100

24 V AC/DC,
220-240 V AC
Star-delta
change-over
with impuls 110-130 V AC

-

1 c/o

CT-EBE 4)

24-240V AC/DC

A
ON-delay
B
OFF-delay
CA Impulse-ON
CB Impulse-OFF
DA Flasher starting with ON
DB Flasher staring with OFF
H
Pulse former
FA Star-delta change-over twice

1SVR550207R1100
1SVR550207R4100

3-300 s

-

1 c/o

CT-YDE
1) 2)

FC
DE

ON-delayed
Star-delta change-over with
impulse
Pulse generator starting		
with ON or OFF

1SVR550200R4100
1SVR550200R2100

-

3)
4)
5)
6)

0.08 (0.18)

0.08 (0.18)

0.08 (0.18)

1 n/o +
1 n/c

CT-SDE
2) 5)

1SVR550210R4100

0.08 (0.18)

1SVR550212R4100

0.1-10 s,
3-300 s

CT-MKE

-

-

3) 6)

solidestate

0.3-30 s

1SVR550019R0000

0.08 (0.18)

1SVR550509R1000
CT-EKE

1SVR550509R4000

0.08 (0.18)

1SVR550509R2000
1SVR550519R1000
-

3-300 s
2)

kg (lb)

1SVR550217R4100
0.3-30 s

0.1-10 s

1)

1SVR550200R1100

3-300 s

24-240 V AC/DC 0.3-30 s

24-240 V AC

1SVR550207R2100

0.3-30 s

3-300 s
OFF-delay

1SVR550167R1100

0.3-30 s

0.1-10 s
ON-delay

1 pce

1SVR550160R1100

380-415 V AC

Multifunctional 8)

Weight
(1 pce)

1SVR550141R4100

0.1-10 s

0.1-10 s
110-130 V AC

1SVR550140R4100

3-300 s

0.1-10 s

Price

1SVR550140R1100
M

110-130 V AC
24 V AC/DC,
220-240 V AC

Order code

CT-AKE

1SVR550519R4000

0.08 (0.18)

1SVR550519R2000

without auxiliary voltage
M Control input with voltage-related triggering
with fixed transition time
- no triggering
solid-state output, functions and time range selection via external jumpers
symetric ON & OFF times
common contact
Functions: ON-delay (AC/DC), Impuls-ON (AC only), Flasher starting with OFF (AC only)

Notice
CT-...KE are solid-state timers with thyristor output for 2-wire applications. They are connected
directly in series with the control coil of contactors or relays. Voltage should not be applied
without a load connected, because there is no current limiting in the unit.

1/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CT-E range
Function diagrams
Remarks
Legend
G Control supply voltage not applied / Output contact open
B Control supply voltage applied / Output contact closed
A1-Y1/B1: Control input with voltage-related triggering

Terminal designations on the device and in the diagrams
The c/o contact is always designated 15-16/18.
The n/o contacts are designated with 15-16 and 15-18.
Control supply voltage is always applied to terminals
A1-A2/B1.
Function of the red LED
The red LED R glows as soon as the output relay energizes
and turns off when the output relay de-energizes.

ON-delay (Delay on make)
CT-ERE, CT-MFE

B

A1-A2/B1
15-18
15-16
green LED
red LED
t

U and/or I and/or I and U and I for overcurrent
2 Adjustment of the threshold value U for overvoltage
2 Adjustment of the threshold value I“ = 1115-1216/1418 ; “U“ = 1115-1216/1418 ; “ 10 A, lateral spacing has to be min. 10 mm

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/22

Current monitoring relays, single-phase
Technical data - Current monitoring relays
Type

2

CM-SRS.1

General data
MTBF
Duty time
Dimensions
(W x H x D)

CM-SRS.2

CM-SRS.M

CM-SFS.2

on request
100%
product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)

Weight

net weight depending on device, see ordering details
gross weight depending on device, see ordering details

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units
Material of housing
Degree of protection
Electrical connection
Wire size

Stripping length

10 mm (0.39 in) at measured current > 10 A
UL 94 V-0
housing / terminals IP50 / IP20
Screw connection technology

fine-strand with(out) wire end ferrule 1
2
rigid 1
2
8

Tightening torque

x 0.5-2.5 mm 2 (1 x 20-14 AWG)
x 0.5-1.5 mm 2 (2 x 20-16 AWG)
x 0.5-4 mm 2 (1 x 20-12 AWG)
x 0.5-2.5 mm 2 (2 x 20-14 AWG)
mm (0.32 in)

0.6-0.8 Nm (5.31-7.08 lb.in)

Environmental data
Ambient temperature range

Easy Connect Technology (Push-in)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)

-

operation / -20...+60 °C / -40...+85 °C
storage
55 °C, 6 cycles

Damp heat (IEC 60068-2-30)
Vibration (sinusoidal) (IEC/EN 60255-21-1)

Class 2

Shock (IEC/EN 60255-21-2)

Class 2

Isolation data
Rated insulation voltage
(VDE 0110, IEC 60947-1,
IEC/EN 60255-5)

2)

supply / 600 V
measuring c
­ ircuit / output
supply / output 1/2 250 V

Rated impulse withstand
supply /measuring 6 kV 1.2/50 µs
circuit / output
voltage U imp (IEC/EN 60947-1,
supply / output 1/2 4 kV 1.2/50 µs
IEC/EN 60255-5)
Pollution degree (VDE 0110, IEC 664, IEC/EN 60255-5)
3
Overvoltage category (VDE 0110, IEC 664, IEC/EN 60255-5)

III

Standards
Product standard

IEC/EN 60255-1, IEC/EN 60255-27, EN 50178

Low Voltage Directive

2006/95/EC

EMC Directive

2004/108/EC

Electromagnetic compatibility
Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 Level 3

radiated, radio-frequency,
electromagnetic field
electrical fast transient / burst

IEC/EN 61000-4-3 Level 3
IEC/EN 61000-4-4 Level 3

surge

IEC/EN 61000-4-5 Level 3

conducted disturbances, induced by
radio-frequency fields

IEC/EN 61000-4-6 Level 3

Interference emission

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22; EN 55022 Class B

high-frequency conducted

IEC/CISPR 22; EN 55022 Class B

2/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Voltage monitoring relays, single-phase
Technical data - Voltage monitoring relays
Type

CM-ESS.1

Input circuit - Supply circuit
Rated control supply voltage U s

Current / power consumption
Power failure buffering time
Transient overvoltage protection
Input circuit - Measuring circuit
Monitoring function

Measuring method
Measuring
inputs

2

AC versions 50/60 Hz
AC/DC versions 50/60 Hz or DC
see data sheet
20 ms
Varistors
B-C
over- or undervoltage monitoring
configurable

Terminal connection
Measuring range AC/DC
Input resistance
Pulse overload capacity t < 1 s
Continous capacity

CM-ExS
B-C
B-C
B-C
3-30 V
6-60 V
30-300 V
600 kq
600 kq
600 kq
800 V
800 V
800 V
660 V
660 V
660 V
adjustable within the indicated measuring range
10 %
3-30 % adjustable
DC / 15 Hz - 2 kHz
DC / 50-60 Hz
AC: 80 ms / DC: 120 ms
U m 0.5 %
U m 0.06 % / °C
Varistors
none

B-C
60-600 V
600 kq
800 V
660 V
5 % fixed

0 or 0.1-30 s adjustable

w0.07 % of full scale
t m 0.5 %
t m 0.06 % / °C

V:
W:
U: red LED V :
W:
R: yellow LED V :
Z:
Y:

control supply voltage applied
tripping delay T V active
overvoltage,
undervoltage
relay energized, no latching function
relay energized, active latching function
relay de-energized, active latching function

Output circuits
Kind of output

1 c/o contact

2 c/o contacts

Operating principle

open-circuit principle

1)

Contact material
Rated operational voltage U e

over- and
undervoltage
monitoring
configurable

True RMS measuring principle

Repeat accuracy (constant parameters)
Accuracy within the control supply voltage tolerance
Accuracy within the temperature range
Indication of operational states
Control supply voltage
U/T: green LED

Relay status

CM-EFS.2

A1-A2 110-130 V AC
A1-A2 220-240 V AC
A1-A2 24-240 V AC/DC
-15...+10 %

Threshold value(s)
Setting accuracy of threshold value
Hysteresis related to the threshold value
Measuring signal frequency range
Rated measuring signal frequency range
Maximum response time
Accuracy within the control supply voltage tolerance
Accuracy within the temperature range
Transient overvoltage protection
Timing circuit
Delay time T V

Measured value

CM-ESS.M
A1-A2

Rated control supply voltage U s tolerance
Rated frequency

CM-ESS.2

1x2 c/o contacts or
2x1 c/o contact
configurable
open- or closed-circuit principle
configurable 1)

AgNi
IEC/EN 60947-1 250 V

Minimum switching voltage / minimum switching current
Maximum switching voltage / maximum switching current
Rated o
­ perational current
AC-12 (resistive) at 230 V
I e (IEC/EN 60947-5-1)
AC-15 (inductive) at 230 V
DC-12 (resistive) at 24 V
DC-13 (inductive) at 24 V
AC rating
Utilization category (Control Circuit Rating Code)
(UL 508)
max. rated operational voltage
max. continuous thermal current at B 300
max. making/breaking apparent power
(Make/Break) at B 300
Mechanical lifetime
Electrical lifetime
AC-12, 230 V, 4 A
Max. fuse rating to achieve shortn/c contact
circuit protection
n/o contact

24 V / 10 mA
250 V AC / 4 A AC
4A
3A
4A
2A
B 300
300 V AC
5A
3600/360 VA
30x10 6 switching cycles
0.1x10 6 switching cycles
6 A fast-acting
10 A fast-acting
10 A fast-acting

6 A fast-acting

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/24

Voltage monitoring relays, single-phase
Technical data - Voltage monitoring relays
Type
General data

2

CM-ESS.1

MTBF
Duty time
Dimensions (W x H x D)
Weight
Mounting
Mounting position
Minimum distance to other units
Material of housing
Degree of protection
Environmental data

product dimensions
packaging dimensions
net weight
gross weight

Ambient temperature ranges
Damp heat, cyclic (IEC/EN 60068-2-30)
Vibration, sinusoidal (IEC/EN 60255-21-1)
Shock (IEC/EN 60255-21-2)
Electrical connection
Wire size

Stripping length
Tightening torque
Isolation data

vertical / horizontal
housing / terminals

CM-ESS.2

CM-EFS.2

on request
100%
22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)
depending on device, see ordering details
depending on device, see ordering details
DIN rail (IEC/EN 60715), snap-on mounting without any tool
any
not necessary / not necessary
UL 94 V-0
IP50 / IP20

operation -20...+60 °C
storage -40...+85 °C
55 °C, 6 cycle
Class 2
Class 2

Screw connection technology
fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG)
2 x 0.5-2.5 mm 2 (2 x 20-14 AWG)
8 mm (0.32 in)
0.6-0.8 Nm (5.31-7.08 lb.in)

Rated insulation voltage
(VDE 0110, IEC 60947-1, IEC/EN
60255-5)
Rated impulse withstand voltage U imp
(IEC/EN 60947-1, IEC/EN 60255-5)

supply / measuring
circuit / output
supply / output 1/2
supply / measuring
circuit / output
supply / output 1/2
Pollution degree (VDE 0110, IEC 664, IEC/EN 60255-5)
Overvoltage category (VDE 0110, IEC 664, IEC/EN 60255-5)
Standards
Product standard
Low Voltage Directive
EMC Directive
Electromagnetic compatibility
Interference immunity to
electrostatic discharge
radiated, radio-frequency,
electromagnetic field

CM-ESS.M

Easy Connect Technology (Push-in)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
-

600 V
250 V
6 kV 1.2/50 µs
4 kV 1.2/50 µs
3
III
IEC/EN 60255-1, IEC/EN 60255-27, EN 50178
2006/95/EC
2004/108/EC

IEC/EN 61000-6-2
IEC/EN 61000-4-2 Level 3
IEC/EN 61000-4-3 Level 3

electrical fast transient / burst
IEC/EN 61000-4-4
surge
IEC/EN 61000-4-5
conducted disturbances, induced by
IEC/EN 61000-4-6
radio-frequency fields
Interference emission
high-frequency radiated
IEC/CISPR 22; EN 55022
high-frequency conducted
IEC/CISPR 22; EN 55022

Level 3
Level 3
Level 3
IEC/EN 61000-6-3
Class B
Class B

1) Open-circuit principle: output relay energizes if the measured value exceeds d / falls below c the adjusted threshold value
Closed-circuit principle: output relay de-energizes if measured value exeeds d / falls below c the adjusted threshold value

2/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Current and voltage monitoring relays, single-phase
Notes

2

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/26

Three-phase monitoring relays
Product group picture

2

2/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Three-phase monitoring relays
Table of contents
Three-phase monitoring relays
Benefits and advantages, Applications

2/29

Operating controls

2/30

Selection table singlefunctional

2/31

Selection table multifunctional

2/32

Ordering details - Singlefunctional

2/33

Ordering details - Multifunctional

2/34

Function diagrams

2/35

Connection diagrams

2/39

DIP switches, Rotary switches

2/40

Technical data

2/41

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/28

2

Three-phase monitoring relays
Benefits and advantages, Applications

2

Characteristics of the CM range three-phase monitors
–– Adjustable phase unbalance threshold value 1)
– – Adjustable ON-delay/OFF-delay time 1)
– – Dual frequency measuring 50/60 Hz
– – Powered by the measuring circuit
– – 1 n/o contact, 1 or 2 c/o contacts
– – LEDs for the indication of operational states
– – Multifunctional and single-functional devices
– – Phase failure detection
– – Phase sequence monitoring 1)
– – Over- and undervoltage monitoring (fixed or adjustable)1)
–– Wide-range operating voltage guarantees world-wide operation
–– Approvals / Marks

AC RK E

1)
2)

2)

/

a b

depending on device type
Applicable in rail application following the latest standards for rail applications: NF
F 16-101/102 (I2/F2 classified), EN 45545 (Hazard Level 3), DIN 5510, EN 50155,
IEC 60571. Further information is available in our rail segment brochure
2CDC110084B0201.

Phase unbalance monitoring
If the supply by the three-phase system is unbalanced due to
uneven distribution of the load, the motor will convert a part of
the energy into reactive power. This energy gets lost unexploited; also the motor is exposed to higher thermal stress.
Other thermal protection devices fail to dete ct continuing
unbalances which can lead to damage or destruction of the
motor. The CM range three-phase monitors with phase unbalance monitoring can reliably detect this critical situation.
Phase sequence
Changing the phase sequence during operation or a wrong
phase sequence prior to startup causes a change of the rotational direction of the connected device. Generators, pumps
or fans rotate in the wrong direction and the installation is no
longer working properly. Especially for moveable equipment,
such as construction machinery, phase sequence detection
prior to the startup process is highly reasonable.
Phase loss
In case of phase loss, undefined stats of the installation are
likely to occur. E.g. the startup process of motors is disturbed.
All three-phase monitors of the ABB CM range detect a phase
loss as soon as the voltage of one phase drops below 60% of
its nominal value.

Extended functionality
ABB’s new generation of three-phase monitoring relays feature
­additional functions making the application field for the devices ­considerably larger.
Selectable phase sequence monitoring
The phase sequence monitoring can be switched off by
means of a rotary switch or a DIP switch. This enables monitoring of three-phase mains where phase sequence is not
relevant for the ­application, for example in case of motors with
forward and reverse rotation, heating applications, etc.
Automatic phase sequence correction
The automatic phase sequence correction is activated by
means of a DIP switch. With activated phase sequence
correction, it is ­ensured that for any non-fixed or portable
equipment, e.g. ­construction ­machinery, the correct phase
sequence is always applied to the ­input terminals of the load.
For details regarding the wiring, please see function description / diagrams.

Structure of the type designation
CM-_ _ x.yz
x: width of enclosure
y: Control supply voltage / measuring range
1
2
3
4
5
6
7
8

110, 115, 120, 127 V supply systems (phaseneutral)
220, 230, 240 V supply systems (phase-neutral)
200, 208, 220, 230, 240, 257, 260 V supply systems (phase-phase)
440, 460 V supply systems (phase-phase)
480, 500 V supply systems (phase-phase)
575, 600 V supply systems (phase-phase)
660, 690 V supply systems (phase-phase)
200, 400 V supply systems (phase-phase)

z: Rated frequency / output circuit
1
2
3

Voltage monitoring
All electric devices can be damaged when operated continuously in a network with out-of-range voltages. For example,
safe starting is not ensured in case of undervoltage. Also,
the switching state of a contactor is not clearly defined when
operated in a „forbidden“ voltage range. This can lead to undefined states of the installtion and cause damage or destruction of valuable parts.

2/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

50/60 Hz – 1x2 c/o
50/60 Hz – 1x2 or 2x1 c/o
50/60/400 Hz – 1x2 oder 2x1 c/o

Three-phase monitoring relays
Operating controls
S-Range Housing

1 Adjustment of the hysteresis >U for overvoltage
2 Adjustment of the threshold value U for overvoltage
2 Adjustment of the threshold value Asym. for phase unbalance
3 Indication of operational states
R/T: red LED – Relay status / timing
F1: yellow LED – Fault message
F2: yellow LED – Fault message

1
2

4 Adjustment of the tripping delay Tv
5 Adjustment of the hysteresis 60% is expected, we recommend to use our three-phase monitoring relays for
unbalance CM-PAS.xx
S: screw connection
P: push-in / easy connect

2/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Three-phase monitoring relays
Ordering details - Multifunctional
Ordering details
Rated control DIP
Monitoring
supply voltage switch function
= measuring
voltage

Neutral
Type
monitoring

90-170 V AC

2CDC 251 065 V0011

180-280 V AC

3x160-300 V AC

A
B
k
l

CM-MPS.23P

Multifunctional
(Three-phase
phase failure
detection,
Phase
sequence
monitoring,
overvoltage,
undervoltage,
Phase
unbalance)

n

3x300-500 V AC

180-280 V AC

3x300-500 V AC

A
B
k
l
m
n
i
j

2CDC 251 062 V0011

3x350-580 V AC

3x450-720 V AC

CM-MPN.52P

A
B
k
l
m
n
i
j

Order code

Price
1 pce

Weight
(1 pce)
kg (lb)

CM-MPS.11S

1SVR730885R1300

0.148 (0.326)

CM-MPS.11P

1SVR740885R1300

0.137 (0.302)

CM-MPS.21S

1SVR730885R3300

0.146 (0.322)

CM-MPS.21P

1SVR740885R3300

0.135 (0.298)

CM-MPS.31S

1SVR730884R1300

0.142 (0.313)

CM-MPS.31P

1SVR740884R1300

0.133 (0.293)

CM-MPS.41S

1SVR730884R3300

0.140 (0.309)

CM-MPS.41P

1SVR740884R3300

0.132 (0.291)

CM-MPS.23S

1SVR730885R4300

0.149 (0.328)

CM-MPS.23P

1SVR740885R4300

0.138 (0.304)

CM-MPS.43S

1SVR730884R4300

0.148 (0.327)

CM-MPS.43P

1SVR740884R4300

0.137 (0.302)

CM-MPN.52S

1SVR750487R8300

0.230 (0.507)

CM-MPN.52P

1SVR760487R8300

0.226 (0.498)

CM-MPN.62S

1SVR750488R8300

0.229 (0.505)

CM-MPN.62P

1SVR760488R8300

0.225 (0.496)

CM-MPN.72S

1SVR750489R8300

0.224 (0.494)

CM-MPN.72P

1SVR760489R8300

0.220 (0.485)

n

Multifunctional
(Three-phase
phase failure
detection,
Phase
sequence
monitoring,
overvoltage,
undervoltage,
Phase
unbalance)

3x530-820 V AC

A
B
k
l
m
n
i
j

ON-delayed
OFF-delayed
Phase sequence
monitoring activated
Phase sequence
monitoring deactivated
Phase sequence
correction activated
Phase sequence
correction deactivated
2x1 c/o (SPDT) contacts
1x2 c/o (SPDT) contacts

S: screw connection
P: push-in / easy connect

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/34

2

Three-phase monitoring relays
Function diagrams

L1, L2, L3, N
Measuring value

L1, L2, L3, N

L1, L2, N

t

s

L1, L2, L3, N

L2, L3, N

L1, L2, L3, N

L3

L1

t

N

U
>U-5%
Measuring value
U
>U-5%
Measuring value
U
>U-5%
Measuring value
U
>U-5%
Measuring value
 400 V
> 400 V
> 220 V
> 400 V
> 220 V
> 400 V
Material of housing
UL 94 V-0
Degree of protection
housing / terminals IP50 / IP20
Electrical connection
Wire size
Screw connection technology
Easy Connect Technology (Push-in)
fine-strand with(out) wire end 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG)
ferrule 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG)
2 x 0.5-2.5 mm 2 (2 x 20-14 AWG)
8 mm (0.32 in)
0.6-0.8 Nm (5.31-7.08 lb.in)

Stripping length
Tightening torque
Environmental data
Ambient temperature ranges
operation / storage
Damp heat (IEC 60068-2-30)
Climatic category
Vibration (sinusoidal) (IEC/EN 60255-21-1)
Shock (IEC/EN 60255-21-2)
Isolation data
Rated insulation
input circuit / output circuit
voltage U i
output circuit 1 / output circuit 2
Rated impulse withstand voltage
input circuit
U imp (VDE 0110, IEC/EN 60664)
output circuit
Test voltage between all isolated circuits (routine test)
Basic insulation
input circuit / output circuit
Protective separation (VDE 0106
input circuit /
part 101 and 101/A, IEC/EN 1140)
output circuit
Pollution degree (VDE 0110, IEC/EN 60664)
Overvoltage category (VDE 0110, IEC 60664)
Standards
Product standard
Low Voltage Directive
EMC directive
RoHS directive
Electromagnetic compatibility
Interference immunity to
electrostatic discharge
IEC/EN 61000-4-2
radiated, radio-frequency,
IEC/EN 61000-4-3
electromagnetic field
electrical fast transient /
IEC/EN 61000-4-4
burst
surge
IEC/EN 61000-4-5
conducted disturbances,
IEC/EN 61000-4-6
induced by radiofrequency fields
Interference emission
high-frequency radiated
IEC/CISPR 22, EN 55022
high-frequency conducted
IEC/CISPR 22, EN 55022

2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
-

-25...+60 °C / -40...+85 °C
55 °C, 6 cycles
3K3
Class 2
Class 2
600 V
300 V
6 kV; 1.2/50 µs
4 kV; 1.2/50 µs
2.5 kV, 50 Hz, 1 s
600 V
3
III
IEC/EN 60255-6, EN 50178
2006/95/EC
2004/108/EC
2011/65/EC
EN 61000-6-1, EN 61000-6-2
Level 3 (6 kV / 8 kV)
Level 3 (10 V/m)
Level 3 (2 kV / 2 kHz)
Level 4 (2 kV L-L)
Level 3 (10 V)
EN 61000-6-3, EN 61000-6-4
Class B
Class B

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/44

2

Three-phase monitoring relays
Technical data
Type

2

CM-MPS.11

CM-MPS.21

Input circuit = Measuring circuit
Rated control supply voltage U S = measuring voltage

L1, L2, L3, N
3x90-170 V AC
3x180-280 V AC

Rated control supply voltage U S tolerance

-15...+10 %

Rated frequency
Frequency range
Typical current / power consumption

50/60 Hz
45-65 Hz
25 mA / 10 VA
25 mA / 18 VA
(115 V AC)
(230 V AC)
L1, L2, L3, N
J
J
can be switched off
J
J

Measuring circuit
Monitoring functions

Phase failure
Phase sequence
Automatic phase sequence correction
Over- / undervoltage

Phase unbalance J
J
Interrupted neutral J
J
Measuring range
Overvoltage 3x120-170 V AC
3x240-280 V AC
Undervoltage 3x90-130 V AC
3x180-220 V AC
Phase unbalance 2-25 % of average of phase voltages
Thresholds
Overvoltage adjustable within measuring range
Undervoltage adjustable within measuring range
Phase unbalance (switch-off value) adjustable within measuring range
Hysteresis related to the
Over- / undervoltage fixed 5 %
threshold value
Phase unbalance fixed 20 %
Rated frequency of the measuring signal
50/60 Hz
Frequency range of the measuring signal
45-65 Hz
Maximum measuring cycle time
100 ms
Accuracy within the rated control supply voltage tolerance
U  0.5 %
Accuracy within the temperature range
U  0.06 % / °C
Measuring method
True RMS
Timing circuit
Start-up delay t S
fixed 200 ms

CM-MPS.31

25 mA / 10 VA
(230 V AC)
J

J

J
-

J
-

3x220-300 V AC
3x160-230 V AC

3x420-500 V AC
3x300-380 V AC

ON- or OFF-delay 0; 0.1-30 s adjustable

Accuracy within the rated control supply voltage tolerance
Accuracy within the temperature range
Indication of operational states
Output circuits
Kind of output
Operating principle
Contact material
Rated operational voltage U e (IEC/EN 60947-1)

t  0.5 %
t  0.06 % / °C
Details see function description / -diagrams
15-16/18, 25-26/28
relay, 1 x 2 c/o contacts
closed-circuit principle 1)
AgNi alloy, Cd free
250 V

Minimum switching power
Maximum switching voltage
Rated operational current I e
(IEC/EN 60947-5-1)

24 V / 10 mA
see „Load limit curves“ on page 127
4A
3A
4A
2A
B 300

1)

Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value

2/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

25 mA / 18 VA
(400 V AC)
L1, L2, L3
J

J

Tripping delay t V

AC-12 (resistive) 230 V
AC-15 (inductive) 230 V
DC-12 (resistive) 24 V
DC-13 (inductive) 24 V
AC rating (UL 508)
Utilization category
(Control Circuit Rating Code)
max. rated operational voltage 300 V AC
max. continuous thermal current at B 300 5 A
max. making/breaking 3600/360 VA
apparent power at B 300
Mechanical lifetime
30 x 10 6 switching cycles
Electrical lifetime (AC-12, 230 V, 4 A)
0.1 x 10 6 switching cycles
Max. fuse rating to achieve short-circuit
n/c contact 6 A fast-acting
protection
n/o contact 10 A fast-acting

CM-MPS.41

L1, L2, L3
3x160-300 V AC
3x300-500 V AC

Three-phase monitoring relays
Technical data
Type

CM-MPS.11

General data
MTBF

CM-MPS.21

CM-MPS.31

CM-MPS.41

on request

Duty time

100%

Dimensions (W x H x D)

2

product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)

Weight

Screw connection technology
Easy Connect Technology (Push-in)
net weight depending on device, see ordering details
gross weight depending on device, see ordering details

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units

horizontal 10 mm (0.39 in) in case of continuous measuring voltages
> 120 V
> 240 V
> 220 V
UL 94 V-0

Material of housing
Degree of protection
Electrical connection
Wire size

> 400 V

housing / terminals IP50 / IP20
Screw connection technology
fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG)
2 x 0.5-2.5 mm 2 (2 x 20-14 AWG)
8 mm (0.32 in)
0.6-0.8 Nm (5.31-7.08 lb.in)

Stripping length
Tightening torque
Environmental data
Ambient temperature ranges
operation / storage
Damp heat (IEC 60068-2-30)
Climatic category
Vibration (sinusoidal) (IEC/EN 60255-21-1)
Shock (IEC/EN 60255-21-2)
Isolation data
Rated insulation v­ oltage
input circuit / output circuit
Ui
output circuit 1 / output circuit 2
Rated impulse withstand voltage U imp
(VDE 0110, IEC/EN 60664)

-

-25...+60 °C / -40...+85 °C
55 °C, 6 cycles
3K3
Class 2
Class 2
600 V
300 V

output circuit 4 kV; 1.2/50 µs
2.5 kV, 50 Hz, 1 s

input circuit / output circuit 600 V

Protective separation (VDE 0106 part
input circuit / output yes
101 and 101/A, IEC/EN 61140)
circuit
Pollution degree (VDE 0110, IEC/EN 60664)
3
Overvoltage category (VDE 0110, IEC 60664)
III
Standards
Product standard
IEC/EN 60255-1, EN 50178
Low Voltage Directive

2006/95/EC

EMC directive

2004/108/EC

RoHS directive

2011/65/EC

Electromagnetic compatibility
Interference immunity to
electrostatic discharge
radiated, radio-frequency,
electromagnetic field
electrical fast transient / burst
surge
conducted disturbances,
induced by radio-frequency fields
harmonics and interharmonics
Interference emission
high-frequency radiated
high-frequency conducted

2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)

input circuit 6 kV; 1.2/50 µs

Test voltage between all isolated circuits (routine test)
Basic insulation

Easy Connect Technology (Push-in)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)

-

EN 61000-6-1, EN 61000-6-2
IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)
IEC/EN 61000-4-3 Level 3 (10 V/m)
IEC/EN 61000-4-4 Level 3 (2 kV / 2 kHz)
IEC/EN 61000-4-5 Level 4 (2 kV L-L)
IEC/EN 61000-4-6 Level 3 (10 V)
IEC/EN 61000-4-13 Class 3
EN 61000-6-3, EN 61000-6-4
IEC/CISPR 22, EN 55022 Class B
IEC/CISPR 22, EN 55022 Class B

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/46

Three-phase monitoring relays
Technical data
Type

CM-MPS.23
L1, L2, L3, N

Input circuit = Measuring circuit
Rated control supply voltage U S = measuring voltage

2

3x180-280
V AC
-15...+10 %

Rated control supply voltage U S tolerance
Rated frequency
Frequency range
Typical current / power consumption
Measuring circuit
Monitoring functions

Measuring range

Phase failure
Phase sequence
Automatic phase sequence correction
Over- / undervoltage
Phase unbalance
Interrupted neutral
Overvoltage
Undervoltage

CM-MPS.43
3x300-500
V AC

CM-MPN.52
CM-MPN.62
L1, L2, L3
3x350-580
V AC

3x450-720
V AC

Start-up delay t S1

fixed 250 ms

Tripping delay t V

ON- or OFF-delay 0; 0.1-30 s adjustable

Accuracy within the rated control supply voltage tolerance
Accuracy within the temperature range
Indication of operational states
Output circuits
Kind of output
Operating principle
Contact material
Rated operational voltage U e 
IEC/EN 60947-1
Minimum switching power
Maximum switching voltage
Rated operational current I e
AC-12 (resistive) 230 V
(IEC/EN 60947-5-1)
AC-15 (inductive) 230 V
DC-12 (resistive) 24 V
DC-13 (inductive) 24 V
AC rating (UL 508)
Utilization category
(Control Circuit Rating Code)
max. rated operational voltage
max. continuous thermal current at B 300
max. making/breaking apparent power at B 300
Mechanical lifetime
Electrical lifetime (AC-12, 230 V, 4 A)
Max. fuse rating to achieve shortn/c contact
circuit protection
n/o contact

t  0.5 %
t  0.06 % / °C
Details see function description / -diagrams
15-16/18, 25-26/28
relay, 2 x 1 or 1 x 2 c/o contacts configurable
closed-circuit principle 1)
AgNi alloy, Cd free
250 V
24 V / 10 mA
see „Load limit curves“ on page 127
4A
3A
4A
2A
B 300

1)

3x530-820
V AC

50/60/400 Hz
50/60 Hz
45-440 Hz
45-65 Hz
5 mA / 4 VA
5 mA / 4 VA
29 mA / 41 VA 29 mA / 52 VA 29 mA / 59 VA
(230 V AC)
(400 V AC)
(480 V AC)
(600 V AC)
(690 V AC)
L1, L2, L3, N
L1, L2, L3
J
J
J
J
J
can be switched off
configurable
J
J
J
J
J
J
J
J
J
J
J
3x240-280
3x420-500
3x480-580
3x600-720
3x690-820
V AC
V AC
V AC
V AC
V AC
3x180-220
3x300-380
3x350-460
3x450-570
3x530-660
V AC
V AC
V AC
V AC
V AC
2-25 % of average of phase voltages
adjustable within measuring range
adjustable within measuring range
adjustable within measuring range
fixed 5 %
fixed 20 %
50/60/400 Hz
50/60 Hz
45-440 Hz
45-65 Hz
100 ms
U  0.5 %
U  0.06 % / °C
True RMS

Phase unbalance
Overvoltage
Undervoltage
Phase unbalance (switch-off value)
Hysteresis related to
Over- / undervoltage
the threshold value
Phase unbalance
Rated frequency of the measuring signal
Frequency range of the measuring signal
Maximum measuring cycle time
Accuracy within the rated control supply voltage tolerance
Accuracy within the temperature range
Measuring method
Timing circuit
Start-up delay t S and t S2
fixed 200 ms
Thresholds

CM-MPN.72

300 V AC
5A
3600/360 VA
30 x 10 6 switching cycles
0,1 x 10 6 switching cycles
6 A fast-acting
10 A fast-acting

10 A fast-acting

Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value

2/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Three-phase monitoring relays
Technical data
Type
General data
MTBF
Duty time
Dimensions (W x H x D)

CM-MPS.23

product dimensions
packaging dimensions

CM-MPS.43

CM-MPN.52

CM-MPN.62

CM-MPN.72

on request
100%
22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)
depending on device, see ordering details
DIN rail (IEC/EN 60715), snap-on mounting without any tool
any
not necessary / not necessary
UL 94 V-0
IP50 / IP20

Weight
Mounting
Mounting position
Minimum distance to other units
vertical / horizontal
Material of housing
Degree of protection
housing / terminals
Electrical connection
Wire size
Screw connection technology
Easy Connect Technology (Push-in)
fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG) 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
2 x 0.5-2.5 mm 2 (2 x 20-14 AWG)
Stripping length
8 mm (0.32 in)
Tightening torque
0.6-0.8 Nm (5.31-7.08 lb.in)
Environmental data
Ambient temperature ranges
operation / storage -25...+60 °C / -40...+85 °C
Damp heat (IEC 60068-2-30)
55 °C, 6 cycles
Climatic category
3K3
Vibration (sinusoidal) (IEC/EN 60255-21-1)
Class 2
Shock (IEC/EN 60255-21-2)
Class 2
Isolation data
Rated insulation v­ oltage U i
input circuit / output 600 V
1000 V
circuit
output circuit 1 / 2 300 V
Rated impulse withstand voltage U imp
input circuit 6 kV; 1.2/50 µs
8 kV; 1.2/50 µs
(VDE 0110, IEC/EN 60664)
output circuit 4 kV; 1.2/50 µs
Test voltage (routine
isolated output circuits 2.5 kV, 50 Hz, 1 s
test) between
input circuit and isolated output circuits 2.5 kV, 50 Hz, 1 s
4 kV, 50 Hz, 1 s
Basic insulation
input circuit / output circuit 600 V
1000 V
Protective separation (VDE 0106 part
input circuit / 101 and 101/A, IEC/EN 61140)
output circuit
Pollution degree (VDE 0110, IEC/EN 60664)
3
Overvoltage category (VDE 0110, IEC 60664)
III
Standards
Product standard
IEC/EN 60255-1, EN 50178
Low Voltage Directive
2006/95/EC
EMC directive
2004/108/EC
RoHS directive
2011/65/EC
Electromagnetic compatibility
Interference immunity to
EN 61000-6-1, EN 61000-6-2
electrostatic discharge
IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)
radiated, radio-frequency,
IEC/EN 61000-4-3 Level 3 (10 V/m)
electromagnetic field
electrical fast transient / burst
IEC/EN 61000-4-4 Level 3 (2 kV / 2 kHz)
surge
IEC/EN 61000-4-5 Level 4 (2 kV
Level 4 (2 kV L-L)
L-N)
conducted disturbances, induced by
IEC/EN 61000-4-6 Level 3 (10 V)
radio-frequency fields
harmonics and interharmonics
IEC/EN 61000-4-13 Class 3
Interference emission
EN 61000-6-3, EN 61000-6-4
high-frequency radiated
IEC/CISPR 22, EN 55022 Class B
high-frequency conducted
IEC/CISPR 22, EN 55022 Class B

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/48

2

Grid feeding monitoring relays Voltage and frequency monitoring functions
Product group picture

2

2/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Grid feeding monitoring relays Voltage and frequency monitoring functions
Table of contents
Grid feeding monitoring relays - Voltage and frequency
monitoring functions
Benefits and advantages, operating controls

2/51

Applications

2/52

Applications, connection diagram

2/53

Ordering and selection

2/54

Technical data - CM-UFD.Mxx

2/55

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/50

2

Grid feeding monitoring relays Voltage and frequency monitoring functions
Benefits and advantages, operating controls
Characteristics CM-UFD.M22
– – ROCOF (rate of change of frequency) monitoring, configurable
– – Third party certificate confirming accordance with CEI 0-21
– – Pre-setting according to CEI 0-21

Characteristics CM-UFD.M31
– – ROCOF (rate of change of frequency) monitoring and vector shift detection, configurable
– – Third party certificate confirming accordance with
VDE-AR-N 4105 and BDEW
– – Pre-settings according to VDE-AR-N 4105 and BDEW

Characteristics CM-UFD.M33
– – ROCOF (rate of change of frequency) monitoring and vector shift detection, configurable
– – Factory certificate confirming accordance with Engineering
Recommendation G59 Issue 3 - September 2013; Engineering Recommendation G83 Issue 2 - December 2012
– – Pre-setting according to G59/3 LV + G83/2 HV
– – UL 508, CAN/CSA C22.2 No.14

CM-UFD.Mxx
1

1 Display
R1 R2 R3 - relay status; in this case R3 is de-energized
FB - status feedback loop Y0-Y1; in this case FB is closed
EXT – status input external signal; in this case input is closed
REM – status remote trip input; in this case input is closed

2

2 Indication of operational states
U/T: green LED – supply voltage applied / flashing = timing active
F: red LED - failure

3

3 Keypad

2CDC 253 020 F0013

2

Characteristics for all CM-UFD devices
–– Monitoring of voltage and frequency in single- and threephase mains 2-wire, 3-wire or 4-wire
–– Over- and undervoltage, 10 minutes average value as well
as over- and underfrequency monitoring
–– Two-level threshold settings for over-/undervoltage and
frequency
–– Multiline, backlit LCD display
–– All threshold values adjustable as absolute values
–– True RMS measuring principle
–– High measurement accuracy
–– 3 control inputs for remote trip, feedback signal, and external signal
–– Tripping delay for each threshold adjustable
–– Interrupted neutral detection
–– Error memory for up to 99 entries (incl. cause of error, measured value, relative timestamp)
–– Test function
–– Password setting protection
–– 3 c/o (SPDT) contacts
–– LEDs for the indication of operational states

2/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

ESC: escape / return to previous menu

^: up / value increase
∨ : down / value decrease

OK: enter / confirm selection

Grid feeding monitoring relays Voltage and frequency monitoring functions
Applications
Example of single-phase application CM-UFD.M22

Example of three-phase application CM-UFD.M22
9

N

230 V AC

L1 N

CP-E 24/X

11
L+ L-

1

24 V DC

L+IN L-IN

CP-B 24/X

L

L N

2CDC 252 004 F0014

L

12
L+OUT L-OUT

13

N

L1 N

CP-E 24/X

230 V AC
8
11

L+ LL+IN L-IN

CP-B 24/X

1

24 V DC
12

L+ OUTL-OUT

13

2

L1 L2 L3 N

2CDC 252 003 F0014

9

24 V DC

24 V DC

7

7

10
A1 A2

Y1 Y2 Y3 Y0

10

L1 L2 L3 N

A1 A2

Y1 Y2 Y3 Y0

L1 L2 L3 N

CM-UFD

ESC

CM-UFD

ESC

U/T
F

U/T
F

OK

OK

14 11 12 24 21 22 34 31 32

14 11 12 24 21 22 34 31 32

4

18 15 16 28 25 26 38 35 36

18 15 16 28 25 26 38 35 36

4

2

3

2

3

6

6

G

5
G

1. Main circuit breaker DG or DGL
2. DDI: Automatic circuit breaker or contactor equipped with low voltage coil and
motor for automatic closure
3. Auxiliary contact of DDI, necessary for realizing the feedback function (compulsory for CM-UFD.M22)
4. DDI short-circuit protection
5. Generator and/or inverter
6. Generator (DDG)
7. Protection fuse for the measuring circuit of the CM-UFD.M22 (optional)
8. Shunt trip coil for feedback function (P>20 kW). This coil can control DG/DGL or
DDG devices

Example of single-phase application - CM-UFD.M31
L1
N

Public grid
where applicable,
a transformer

5

9. Control supply voltage for CM-UFD.M22 (SPI) and tripping device (DDI)*
10. Device protection fuse for the CM-UFD.M22
11. Primary switch mode power supply unit CP-E (230 V AC / 24 V DC) for the buffer module CP-B*
12. Ultra-capacitor based buffer module CP-B (24 V DC in/out)
13. Wire protection fuse for the output of the buffer module CP-B
* In accordance to CEI 0-21 regulation, in case of loss of control supply voltage it’s asked to guarantee, at least for 5 seconds, the functionality
of the CM-UFD.M22, the operability of the DDI and when present the command coil for operating the redundancy device. This function has to
be realized by external buffer or UPS devices.

Example of three-phase application - CM-UFD.M31
L1
L2
L3
N

Public grid
where applicable,
a transformer

6 A
10 A
A1

A2

1115

10 A

10 A
2125

3135

6 A
L1

L2

L3

N
A1

A2

1115

2125

3135

L1

L2

L3

N

  
1216

1418

2226

2428

3236

3438

Y3

Y2

Y1

Y0

  
1216



K1

1418

2226

2428

3236

3438



Y2

Y1

Y0


K1

K2

Y3










K2

 Control input 1, feedback loop for switching device 1

 Switching device 1 of the section switch
 Switching device 2 of the section switch

Inverter(s)
Generator(s)

 Control input 1, feedback loop for switching device 1
 Control input 2, feedback loop for switching device 2
 Control input 3 (e.g. for remote trip)
 Switching device 1 of the section switch
 Switching device 2 of the section switch

Inverter(s)
Generator(s)
2CDC 252 007 F0213

 Control input 3 (e.g. for remote trip)

2CDC 252 006 F0213

 Control input 2, feedback loop for switching device 2

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/52

Grid feeding monitoring relays Voltage and frequency monitoring functions
Applications, connection diagram
Example of single-phase application - CM-UFD.M33
L1
N

L1
L2
L3
N

8
7

8
7

6 A
10 A
A1

A2

10 A

10 A

1115

3135

2125

6 A
L1

L2

L3

N

10 A
A1

10 A

10 A

1115

A2

2125

3135

L1

L2

L3

N

3 2 1
1216

1418

2226

3236

2428

3438

Y3

Y2

Y1

Y0

3 2 1
1216

1

K1

1418

2226

2428

3236

3438

Y3

Y2

Y0

1

K1

2

K2

Y1

4
4

5
K2

2

5

1 Control input 1, feedback loop for switching device 1
2 Control input 2, feedback loop for switching device 2

6
2CDC 252 005 F0014

4 Switching device 1 of the section switch
5 Switching device 2 of the section switch
6 Inverter(s) / generator(s)
7 Transformer (if applicable)
8 Public grid

1 Control input 1, feedback loop for switching device 1
2 Control input 2, feedback loop for switching device 2
3 Control input 3 (e.g. for remote trip)
4 Switching device 1 of the section switch
5 Switching device 2 of the section switch
6 Inverter(s) / generator(s)
7 Transformer (if applicable)

2CDC 252 006 F0014

3 Control input 3 (e.g. for remote trip)

8 Public grid

Electrical connection - CM-UFD.Mxx
A1

A2

Y1

Y2

Y3

Y0

L1

L2

L3

N
2CDC 253 007 F0014

2

Example of three-phase application - CM-UFD.M33

A1-A2
L1, L2, L3, N
Y1-Y0
Y2-Y0
Y3-Y0

CM-UFD

ESC Test
U/T
F

1115 -1216/1418
2125 -22 26/2428
3135 -3236/34 38

OK

14

11

12

24

21

22

34

31

32

18

15

16

28

25

26

38

35

36

2/53 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Control supply voltage U s
Measuring inputs
Control input 1: Feedback from switching device 1
Control input 2: Feedback from switching device 2
Control input 3: Remote trip, suppress Y1, suppress Y2,
suppress Y1/Y2 or suppress vector shift detection
Output relay 1: Relay for tripping switching device 1
of the section switch, closed-circuit principle
Output relay 2: Relay for tripping switching device 2
of the section switch, closed-circuit principle
Output relay 3: Closing command for circuit breaker
motor, configuration possibilities: closed-circuit
principle, open-circuit principle, disabled or
synchronous with R1/R2

Grid feeding monitoring relays Voltage and frequency monitoring functions
Ordering and selection

Ordering details
Rated control supply voltage =
measuring voltage

Type

Order code

24-240 V AC/DC

CM-UFD.M22

1SVR510730R0300

24-240 V AC/DC

CM-UFD.M31

1SVR510730R0300

24-240 V AC/DC

CM-UFD.M33

1SVR560730R3400

Price

1SVR560730R3400

1SVR560730R3401

1SVR560730R3402

CM-UFD.M31

CM-UFD.M33

Rated control supply voltage Us
24-240 V AC/DC
Standard

Order number

1 pce

CM-UFD.M22

CM-UFD.Mxx

Only reliable and continuous monitoring of a three-phase network guarantees the trouble-free
and economic operation of machines and installations.

Type

2CDC 251 005 S0013

Description

J

J

J

Weight
(1 pce)
kg (lb)
0.225
(0.496)
0.225
(0.496)
0.304
(0.670)

J

VDE AR-N 4105, BDEW

J

G59/3
J

CEI 0-21
Rated frequency
DC or 50 Hz
DC or 50/60 Hz
Suitable for monitoring

J

J
J

Single-phase mains

J

J

J

Three-phase mains

J

J

J

Over-/undervoltage

J

J

J

Over-/underfrequency

J

J

J

ROCOF (rate of change of frequency)

J
J

J

J

J

J

Vector shift

J

J

Thresholds

adj adj adj

Monitoring function

10 minutes average value

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/54

2

Grid feeding monitoring relays Voltage and frequency monitoring functions
Technical data - CM-UFD.Mxx
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated

2

Type

CM-UFD.M22

Input circuit - Supply circuit
Rated control supply voltage U s

24-240 V AC/DC

Rated control supply voltage U s tolerance

-15…+10 %

Rated frequency
Frequency range AC
Typical current / power consumption

overvoltage 10-min average (>UAV) adjustable,
1.00-1.30 * U s
in 0.01*U s steps
overvoltage (>U1) adjustable,
1.00-1.20 * U s
in 0.01*U s steps
overvoltage (>U2) undervoltage (F1) adjustable,
50.0-54.0 Hz
in 0.1 Hz steps
underfrequency (F1) adjustable,
50.0-54.0 Hz
in 0.1 Hz steps
underfrequency (UAV ) overvoltage (>U1, >U2)
undervoltage (F1, >F2)
underfrequency ( 240 V

Mounting
Mounting position
Minimum distance to other units

Material of housing
Degree of protection
Electrical connection

Stripping length
Tightening torque
Environmental data
Ambient temperature ranges
Climatic category
Damp heat, cyclic
Vibration, sinusoidal
Shock, half-sine
1)

10 mm (0.39 in)
at U n > 400 V

UL 94 V-0
housing / terminal IP50 / IP20
Screw connection technology

Wire size

45 x 85.6 x 103.7 mm
(0.89 x 3.37 x 4.08 in)
97 x 109 x 30 mm
(3.82 x 4.29 x 1.18 in)
CM-IWN.xP:
0.217 kg (0.478 lb)
CM-IWN.xS:
0.241 kg (0.531 lb)
CM-IWN.xP:
0.246 kg (0.542 lb)
CM-IWN.xS:
0.270 kg (0.595 lb)
without any tool

fine-strand with(out) wire end 1 x 0.5-2.5 mm 2 (1 x 20-14 AWG)
ferrule 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG)
2 x 0.5-2.5 mm 2 (2 x 20-14 AWG)
8 mm (0.32 in)
0.6-0.8 Nm (5.31-7.08 lb.in)
operation / storage / transport
IEC/EN 60721-3-3
IEC/EN 60068-2-30
IEC/EN 60255-21-1
IEC/EN 60255-21-2

Closed-circuit principle: Output relay(s) de-energize(s) if a fault is occuring
Open-circuit principle: Output relay(s) energize(s) if a fault is occuring

2/69 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Easy Connect Technology
(Push-in)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)

-25...+60 °C/-40...+85 °C/-40...+85 °C
3K5 (no condensation, no ice formation)
6 x 24 h cycle, 55 °C, 95 % RH
Class 2
Class 2

Insulation monitoring relays for unearthed supply systems
Technical data
CM-IWS.2

CM-IWS.1

CM-IWN.1, 4, 5, 6

Isolation data
Rated impulse withstand voltage U imp between
all isolated circuits
(IEC/EN 60947-1, IEC/EN 60664-1, VDE 0110-1)

supply / measuring circuit 6 kV
supply / output circuit 6 kV
measuring / output circuit 6 kV
output 1 / output circuit 2
4 kV
Pollution degree (IEC/EN 60664-1, VDE 0110-1)
3
Overvoltage category (IEC/EN 60664-1, VDE 0110-1)
III
Rated insulation voltage U i
supply / measuring circuit 400 V
300 V
600 V
(IEC/EN 60947-1, IEC/EN 60664-1, VDE 0110-1)
supply / output circuit 300 V
supply / measuring circuit 400 V
300 V
600 V
output 1 / output circuit 2 300 V
Basis isolation for rated control supply voltage
supply / measuring circuit 400 V AC / 300 V DC 250 V AC / 300 V DC 400 V AC / 600 V DC
(IEC/EN 60664-1, VDE 0110-1)
supply / output circuit 250 V AC / 300 V DC
measuring / output circuit 400 V AC / 300 V DC 250 V AC / 300 V DC 400 V AC / 600 V DC
output 1 / output 2 250 V AC / 300 V DC
Protective separation (IEC/EN 61140)
supply / output circuit 250 V AC / 250 V DC
supply / measuring circuit 250 V AC / 250 V DC
measuring / output circuit 250 V AC / 250 V DC
Test voltage between all isolated circuits,
supply / output circuit 2.32 kV, 50 Hz, 2 s
routine test (IEC/EN 60255-5, IEC/EN 61010-1)
supply / measuring circuit 2.32 kV, 50 Hz, 2 s
measuring / output circuit 2.2 kV, 50 Hz, 1 s
2.53 kV, 50 Hz, 1 s
Standards
Product standard
IEC/EN 61557-1, IEC/EN 61557-8, IEC/EN 60255-1, EN 50178
Other standards
EN 50178
Low Voltage Directive
2006/95/EC
EMC Directive
2004/108/EC
RoHS Directive
2011/65/EC
Electromagnetic compability
Interference immunity to
IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61326-2-4
electrostatic discharge
IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz)
electrical fast transient/burst
IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz
surge
IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit and measuring circuit
1 kV L-L, 2 kV L-earth
conducted disturbances, induced by
IEC/EN 61000-4-6 Level 3, 10 V
radio-frequency fields
voltage dips, short interruptions and
IEC/EN 61000-4-11 Class 3
voltage variations
harmonics and interharmonics
IEC/EN 61000-4-13 Class 3
Interference emissions
IEC/EN 61000-6-3, IEC/EN 61000-6-4
high-frequency radiated
IEC/CISPR 22, EN 55022 Class B
high-frequency conducted
IEC/CISPR 22, EN 55022 Class B

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/70

2

Insulation monitoring relays for unearthed supply systems
Technical data CM-IVN
Input circuit - Measuring circuit
Function

2

VL+, VL-, Vw
expansion of the nominal voltage range of the insulation monitoring relay
CM-IWN to 690 V AC or 1000 V DC, max. length of connection cable 40 cm
see CM-IWN
0-690 V AC / 0-1000 V DC
0-793.5 V AC / 0-1150 V DC (tolerance +15 %)
DC or 15-400 Hz

Measuring principle
Nominal voltage U n of the distribution system to be monitored
Voltage range of the distribution system to be monitored
Rated frequency f N of the distribution system to be monitored
Tolerance of the rated frequency f N
System leakage capacitance C e
Extraneous DC voltage U fg (when
connected to an AC system)
Tolerance of the adjusted threshold value /
Relative percentage uncertainty A at
-5...+ 45 °C, U n = 0-115 %, U s = 85-110 %, f N , f s , C e = 1 μF
Internal impedance Z i
Internal DC resistance R i
Measuring voltage U m
Tolerance of measuring voltage U m
Measuring current I m

13.5-440 Hz
max. identical to that of the insulation monitoring relay used
max. 793.5 V DC
at 1-15 kΩ R F ±1.5 kΩ
at 15-200 kΩ R F ±8 %
at 50 Hz 195 kΩ
200 kΩ
24 V
+10 %
0.15 mA

General data
MTBF
Duty time
Dimensions (W x H x D)
Weight

gross weight
net weight

Mounting
Mounting position
Minimum distance to other units

vertical
horizontal

Degree of protection
Electrical connection
Wire size

fine-strand with(out) wire 2 x 0.75-2.5 mm² (2 x 18-14 AWG)
end ferrule
rigid 2 x 0.5-4 mm² (2 x 20-12 AWG)
7 mm (0.28 in)
0.6-0.8 Nm (5.31-7.08 lb.in)
40 cm

Stripping length
Tightening torque
Max. length of connection cable to CM-IWN
Environmental data
Ambient temperature ranges
operation
Climatic category
Damp heat, cyclic
Vibration, sinusoidal
Shock, half-sine
Isolation data
Rated impulse withstand voltage U imp between all
isolated circuits
(IEC/EN 60947-1, IEC/EN 60664-1,VDE 0110-1)
Pollution degree (IEC/EN 60664-1, VDE 0110-1)
Overvoltage category (IEC/EN 60664-1, VDE 0110-1)
Rated insulation voltage U i
(IEC/EN 60947-1, IEC/EN 60664-1,VDE 0110-1)
Test voltage between all isolated circuits, routine test
(IEC/EN 60255-5, IEC/EN 61010-1)
Standards
Product standard
Other standards
Low Voltage Directive
EMC Directive
RoHS Directive
Electromagnetic compability
Interference immunity to
electrostatic discharge
radiated, radio-frequency,
electromagnetic field
electrical fast transient/burst
surge
conducted disturbances, induced by
radio-frequency fields
voltage dips, short interruptions and
voltage variations
harmonics and interharmonics
Interference emission
high-frequency radiated
high-frequency conducted

on request
100 %
45 x 78 x 100 mm (1.78 x 3.07 x 3.94 in)
0.200 kg (0.441 lb)
0.169 kg (0.373 lb)
DIN rail (IEC/EN 60715), snap-on mounting without any tool
any
not necessary
10 mm (0.39 in) at U n > 600 V
IP50 / IP20

/ storage / transport
IEC/EN 60721-3-3
IEC/EN 60068-2-30
IEC/EN 60255-21-1
IEC/EN 60255-21-2

-25...+60 °C / -40...+85 °C / -40...+85 °C
3K5 (no condensation, no ice formation)
6 x 24 h cycle, 55 °C, 95 % RH
Class 2
Class 2

input circuit / PE 8 kV
3
III
input circuit / PE 1000 V
input circuit / PE 3.3 kV, 50 Hz, 1 s
IEC/EN 61557-1, IEC/EN 61557-8, IEC/EN 60255-1, EN 50178
EN 50178
2006/95/EC
2004/108/EC
2011/65/EC
IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61326-2-4
IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV
IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz)
IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz
IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit
and measuring circuit 1 kV L-L, 2 kV L-earth
IEC/EN 61000-4-6 Level 3, 10 V
IEC/EN 61000-4-11 Level 3

IEC/EN 61000-4-13 Level 3
IEC/EN 61000-6-3, IEC/EN 61000-6-4
IEC/CISPR 22, EN 50022 Class B
IEC/CISPR 22, EN 50022 Class B

2/71 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Insulation monitoring relays for unearthed supply systems
Notes

2

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/72

Motor load monitoring relays
Product picture

2

2/73 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Motor load monitoring relays
Table of contents
Motor load monitoring relays
Fields of application

2/75

Ordering details

2/76

Technical information

2/77

Technical data

2/78

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/74

2

Motor load monitoring relays
Fields of application
(e.g. pressure transducers, current measurement), cos ϕ
monitoring is a more precise and economical alternative.
The motor is used as a sensor for its own load status.

Pump control
Dry-running protection

Detected fault - installation is
switched off

M 3~

L1
L2
L3
N

50-60 Hz

~
~

110-500 V, 15-400 Hz

50-60 Hz

L1
L2
L3
N

U1

U V W

M 3~

U2

M 1~

110-240 V

15-400 Hz

DC

K1

Starting time delay

Detected fault - installation is
switched off

Wiring examples (for motor
currents  20 A)

K1

L1
L2
L3

1SVC 110 000 F 0473

1SVC 110 000 F 0472
Starting time delay

AC

2/75 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

50-60 Hz

U V W

M 3~

K

l

L

K1

U V W

M 3~

L1
N

K1

k

1SVC 110 000 F 0131

U V W

1SVC 110 000 F 0471

Filter pollution

V-belt monitoring

50-60 Hz

k

K

l

L

K1

U1

U2

M 1~

1SVC 110 000 F 0132

K1

Response delay

1SVC 110 000 F 0132

L1
N

Detected fault - installation is
switched off

Ventilator monitoring

1SVC 110 000 F 0133

50-60 Hz

Starting time delay

Detected fault - installation is
switched off
Response delay

1SVC 110 000 F 0131

L1
L2
L3
N

Filter pollution

1SVC 110 000 F 0470
Starting time delay

Wiring examples (for motor currents  20 A)

1SVC 110 000 F 0133

2

The motor load monitor relay monitors the load states of
single-phase and three-phase asynchronous motors.
The evaluation of the phase angle between current and voltage allows a very precise monitoring of the load states.
Compared with other conventional measuring principles
Main applications
–– Pump monitoring
–– Dry-running protection (underload)
–– Closed valves (overload)
–– Pipe break (overload)
–– Heating, air-conditioning, ventilation
–– Monitoring of filter pollution
–– V-belt breakage (underload)
–– Closed shutters/valves (overload)
–– Air ventilating volume
–– Agitating machines
–– High consistency within the tank (overload)
–– Pollution of the tank (overload)
–– Transport/Conveyance
–– Congested conveyor belts (overload)
–– Jamming of belts (overload)
–– Material accumulation in spiral conveyors (overload)
–– Lifting platforms
–– Machine installation
–– Wear of tools, e.g. worn saw blades in circular saws,
etc. (overload)
–– Tool breakage (underload)
–– V-belt drives (breakage underload)

Motor load monitoring relays
Ordering details
Description

1SVR 450 335 F0100

The motor load monitor CM-LWN monitors the load of single-phase and three-phase asynchronous motors. The evaluation of the phase angle between current and voltage (cos j
monitoring) allows a very precise monitoring of the load status.
Ordering details
Rated control supply voltage Current range Type
= measuring voltage

CM-LWN

Order code

Price

Weight
(1 pce)

1 pce

kg (lb)

24-240 V AC/DC

1SVR450335R0000

0.30 (0.66)

110-130 V AC

1SVR450330R0000

0.30 (0.66)

220-240 V AC

1SVR450331R0000

0.30 (0.66)

380-440 V AC

0.5-5 A

1SVR450332R0000

0.30 (0.66)

480-500 V AC

1SVR450334R0000

0.30 (0.66)

1SVR450335R0100

0.30 (0.66)

1SVR450330R0100

0.30 (0.66)

1SVR450331R0100

0.30 (0.66)

380-440 V AC

1SVR450332R0100

0.30 (0.66)

480-500 V AC

1SVR450334R0100

0.30 (0.66)

CM-LWN

24-240 V AC/DC
110-130 V AC
220-240 V AC

2-20 A

Current transformers see „General technical data, Accessories, Current transformers“ on page 128.

Characteristics
– – Pump monitoring
– – Under- and overload monitoring cos j in one unit
– – Adjustable starting delay 0.3-30 s
– – Direct measurement of currents up to 20 A
– – Adjustable response time delay 0.2-2 s
– – Single-phase or three-phase monitoring
– – 2 x 1 c/o contact, closed-circuit principle
– – 3 LEDs for status indication

1 Starting delay „Time S“
2 Response delay „Time R“

1
2

3 Threshold for load limit cos ϕmax
4 Threshold for load limit cos ϕmin
5 Reset button
6 Indication of operational states

3
4

U: green LED – control supply voltage
cos ϕ max: red LED – cos ϕ max exceeded
cos ϕ min: red LED – below cos ϕ min
7 Marker label

5

2CDC 253 010 F0013

7

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/76

2

Motor load monitoring relays
Technical information

1SVC 110 000 F0130

Function diagram - CM-LWN
A1-A2
Current in L1

con ϕmax
hysteresis
con ϕmin
15-18
15-16
25-28
25-26
Reset button
Red LED - cos ϕmin
Red LED - cos ϕmax

TS

TR

TR

TR TS

Connection diagram CM-LWN
2CDC 252 105 F0004

2

The CM-LWN module monitors the load status of inductive loads.
The primary application is the monitoring of single- or three-phase asynchronous motors (squirrel cage) under varying load
conditions. The measuring principle is based on the evaluation of the phase shift (ϕ) between the voltage and the current in one
phase.
The phase difference is nearly inversely proportional to the load. Therefore, cos ϕ, measured relatively from 0 to 1, measures
the relationship of effective power to apparent power. A value towards 0 indicates low load and a value towards 1 indicates
high load.
Threshold values can be set individually for cos ϕ max and cos ϕ min If the set threshold value is reached, a LED lights up and the
relay is de-energized.
If cos ϕ returns to the acceptable limits (taking into account the hysteresis), the relay is reset to its original state and the LED
flashes permanently to indicate the occurrence of the trip event. This message can be deleted using the reset button or by
switching off the supply.
A time delay (Time S) of 0.3 to 30 s can be set for the starting phase of the motor. It is also possible to set a response delay
time (Time R) of 0.2 to 2 s to suppress unwanted tripping due to unavoidable short load changes during normal operation.
To guarantee correct operation of the response delay (Time R), the adjusted value for cos ϕ max has to be higher than the value
for cos ϕ min plus the hysteresis. Consequently, the overload and underload indication must not be active at the same time.
Due to the internal electrical isolation of the supply circuit and the measuring circuit, it is also possible to use the device in systems with different supply voltages.

A1-A2			
L1/K-L1/L		
L1/K-L2-L3
15-16/18		
25-26/28		
			

Rated control supply voltage
Measuring current
Measuring voltage
Output contacts - underload (cos ϕ min)
Output contacts - overload (cos ϕ max)
closed-circuit principle

2/77 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Motor load monitoring relays
Technical data
Type
Input circuit - Supply circuit
Rated control supply voltage U s - power
consumption

Rated control supply voltage U s tolerance
Rated frequency
Duty time
Measuring circuit
Monitoring function

A1-A2
A1-A2
A1-A2
A1-A2
A1-A2
AC versions
AC/DC versions

Voltage range
Current range
Permissible overload of current input
Thresholds

CM-LWN
A1-A2
24-240 V AC/DC approx. 8.4 VA/W
110-130 V AC approx. 3.6 VA
220-240 V AC approx. 3.6 VA
380-440 V AC approx. 3.6 VA
480-500 V AC approx. 3.6 VA
-15 %...+10 %
50-60 Hz
15-400 Hz or DC
100 %
L1/L-L1/K-L2-L3
Motor load monitoring by cos ϕ

L1/K-L2-L3 110-500 V AC single-phase or three-phase
L1/L-L1/K 0.5-5 A version 2-20 A version
25 A for 3 s 100 A for 3 s
cos ϕmin and cos ϕmax adjustable from 0 to 1

Hysteresis (related to phase angle ϕ in °)
Frequency of measuring voltage
Response time
Timing circuits
Start-up time (Time S)
Response delay (Time R)
Accuracy within the rated control supply voltage tolerance
Accuracy within the temperature range
Indication of operational states
Control supply voltage
below cos ϕmin
cos ϕmax exceeded

4°
15-400 Hz
300 ms

Output circuits
Kind of output
Operational principle
Contact material
Rated voltage (VDE 0110, IEC 664-1, IEC 947-1)
Max. switching voltage
Rated operational current I e (IEC/EN 60947-1)

15-16/18, 25-26/28
2 x 1 c/o contact
closed-circuit principle 1)
AgCdO
250 V
400 V AC, 300 V DC
4A
3A
4A
2A
B 300
300 V AC
5A
3600/360 VA
30 x 10 6 switching cycles
0.1 x 10 6 switching cycles
10 A fast-acting / 10 A fast-acting

AC rating (UL 508)

indication of over- and undervoltage fault
0.3-30 s, adjustable
0.2-2 s, adjustable
t m 0.5 %
t m 0.06 % / °C
U: green LED
cos ϕmin: red LED
cos ϕmax: red LED

AC-12 (resistive) 230 V
AC-15 (inductive) 230 V
DC-12 (resistive) 24 V
DC-13 (inductive) 24 V
Utilization category (Control Circuit Rating Code)
max. rated operational voltage
max. continuous thermal current at B 300
max. making/breaking apparent power at B 300

Mechanical lifetime
Electrical lifetime
at AC-12, 230 V, 4 A
Max. fuse rating to achieve short-circuit
n/c / n/o contact
protection
General data
Dimensions (W x H x D)
Mounting position
Degree of protection
housing / terminals
Ambient temperature range
operation / storage
Mounting
Electrical connection
Wire size
fine-strand with wire end ferrule
Standards
Product standard
Low Voltage Directive
EMC Directive
Electromagnetic compatibility
electrostatic discharge
IEC/EN 61000-4-2
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3
electrical fast transient / burst
IEC/EN 61000-4-4
surge
IEC/EN 61000-4-5
conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6
Operational reliability (IEC 68-2-6)
Mechanical resistance (IEC 68-2-6)
Environmental testing (IEC 68-2-30)
Isolation data
Rating (HD 625.1 S1, VDE 0110, IEC 664-1, IEC 60255-5)
Rated insulation voltage between supply- , measuring- and output circuit
Rated impulse withstand voltage between all isolated circuits
Test voltage between all isolated circuits
Pollution category
Overvoltage category
1)

45 mm x 78 mm x 100 mm (1.77 inch x 3.07 inch x 3.94 inch)
any
IP50 / IP20
-25...+65 °C / -40...+85 °C
DIN rail (IEC/EN 60715)
2 x 2.5 mm 2 (2 x 14 AWG)
IEC 255-6, EN 60255-6
2006/95/EC
2004/108/EC, 91/263/EEC, 92/31/EEC, 93/68/EEC, 93/67/EEC
EN 61000-6-2, EN 61000-6-4
Level 3 (6 kV / 8 kV)
Level 3 (10 V/m)
Level 3 (2 kV / 5 kHz)
Level 4 (2 kV L-L)
Level 3 (10 V)
5g
10 g
24 h cycle time, 55 °C, 93 % rel., 96 h
250 V, 400 V, 500 V depending on the version
4 kV / 1.2 - 50 µs
2,5 kV, 50 Hz, 1 min.
3
III

Open-circuit principle: Output relay is energized if the measured value exceeds/drops below the adjusted threshold.
Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/78

2

Motor control and protection
Product group picture

2

2/79 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Motor control and protection
Table of contents
Motor control and protection
Benefits and advantages

2/81

Technical data

2/82

2

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/80

Motor control and protection
Benefits and advantages

2

UMC100.3 is a flexible, modular and expandable motor management system for constant-speed low-voltage range motors.
It's most important tasks include motor protection, prevention of plant standstills and the reduction of down time. This is made
possible by early information relating to possible motor problems which avoids unplanned plant standstills. Even if a motor
trips, quick diagnosis of the cause of the fault serves to reduce downtime.
UMC100.3 combines in a very compact unit:

Motor protection
– – Overload, underload
– – Overvoltage, undervoltage
– – Blocked rotor, low / high current
– – Phase failure, imbalance, phase sequence
– – Earth leakage
– – Thermistor protection
– – Limitation of starts per time
– – One single version with integrated measuring system covers the rated motor current from 0.24 to 63 A
Motor control
– – Integrated and easy to parametrize motor starter functions
like direct, reverse, star-delta,...
– – Additionally free programmable logic for application specific control functions
– – Expansion modules DX111, DX122 for more I/Os
– – Expansion modules VI150, VI155 for 3-phase voltage
measuring
– – Analog and temperature module AI111
Motor diagnostics
– – Quick and comprehensive access to all relevant data via
fieldbus and/or operator panel
– – Current, thermal load
– – Phase voltages
– – Power factor
– – Energy

Further information
UMC Catalog
UMC Brochure

Communication
–– Communication-independent basic device
–– Freely selectable fieldbus protocol with FieldBusPlug
–– Profibus DP
–– DeviceNet
–– Modbus RTU
–– Ethernet Modbus TCP
–– Profinet
Typical application segments
–– Oil & gas
–– Cement
–– Paper
–– Mining
–– Steel
–– Chemical industry

2CDC 190 022 C0206
2CDC 135 011 B0203

2/81 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Motor control and protection
Technical data
Basic device UMC100.3
Main power
Voltage

max 1000 V AC

Frequency

45…65 Hz

Rated motor current

0.24…63 A, without accessories
Higher currents with external transformer

Tripping classes

5E, 10E, 20E, 30E, 40E in accordance with EN/IEC 60947-4-1

Short-circuit protection

Separate fuse on network side

Control unit
Supply voltage

24 V DC, 110-240 V AC/DC

Inputs

6 digital inputs 24 V DC
1 PTC input

Outputs

3 digital relay outputs
1 digital transistor output

Expansion modules

The UMC100.3 can be expanded with maximum 4 expanstion modules: One digital expansion module DX111 or
DX122, one module VI150 or VI155 and 2 analog modules AI111.
Communication takes place via a simple two-wire line. The maximum distance allowed between the UMC100.3
and the expansion module is 3 m.
Digital expansion modules DX111 / DX122
Expands the UMC100.3 to include additional digital inputs and outputs and an analog output
Supply voltage

24 V DC

Inputs

DX111: 8 digital inputs 24 V DC
DX122 8 digital inputs 110/230 V AC

Outputs

4 digital relay outputs
1 analog output, 0/4…20 mA, / 0…10 V configurable

Voltage modules VI150/VI155
Voltage modules for determining phase voltages, power factor (cos j), active power, apparent power, energy,
harmonic content (THD)
VI150 for use in grounded networks
VI155 for use in grounded and ungrounded networks
Supply voltage

24 V DC

Voltage inputs

L1, L2, L3

Rated voltage range

150 … 690 V AC

Outputs

1 digital relay output

Analog module AI111
Expand the UMC100.3 with analog and temperature inputs
Supply voltage

24 V DC

Inputs

0-10 V, 0/4-20 mA
PT100, PT1000, 2- or 3-wire connection
KTY83, KTY84, NTC

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/82

2

Motor control and protection
Technical data
Ethernet communication interfaces
Mounted in the MCC cable chamber; connection of 1 to 4 motor controllers UMC100.3 via simple cables
MTQ22 for Modbus TCP
PNQ22 for Profinet IO

2

Fieldbus communication interfaces
Can be mounted direct on the UMC100.3 or separate in the cable chamber of the MCC.
Connection for standard fieldbus cables with 9-pole Sub-D (Profibus DP) or terminal blocks
PDP32 for Profibus DP
DNP31 for DeviceNet
MRP31 for Modbus RTU

CEM11 earth leakage sensors
Summation current transformer for connecting to a digital input
Mounting with bracket on DIN busbar or wall
Models
CEM11-FBP.20 80 – 1,700 mA
20 mm Ø
CEM11-FBP.35 100 – 3,400 mA
35 mm Ø
CEM11-FBP.60120 – 6,800 mA
60 mm Ø
CEM11-FBP.120 300 – 13,600 mA 120 mm Ø

Current transformer CT4L / CT5L
Only required for rated motor currents >63 A
Linear transformer, 3-phase with terminal block, designed for connecting leads Cu 2.5 mm 2

UMC100-PAN control panel
Installation on the device or on the switching cabinet door
Graphics-enabled and backlit display, 3 LEDs for status indication
Freely configurable error messages
USB port for PC connection
Multilingual: German, English, French, Italian, Polish, Portuguese, Spanish, Russian

2/83 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Motor control and protection
Notes

2

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/84

Thermistor motor protection relays
Product group picture

2

2/85 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Thermistor motor protection relays
Table of contents
Thermistor motor protection relays
Benefits and advantages, Applications

2/87

Operating controls

2/88

Selection table CM-MSS range

2/89

Ordering details

2/90

Ordering details - PTC temperature sensors C011

2/91

Technical data

2/92

Connection diagrams

2/95

Circuit diagram

2/96

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/86

2

Thermistor motor protection relays
Benefits and advantages, Applications

2

The thermistor motor protection relays of the CM-MSx range protect motors with
PTC sensors against high temperature. These sensors are incorporated in the
motor windings thus measuring the motor heat directly.
Direct temperature measuring
Generally, motor damages caused by overload or overheating
situations can be prevented in different ways. Compared to
the indirect temperature measuring which monitors the motor
current, the temperature inside the motor can be measured by
direct temperature measuring.
This enables direct control and evaluation of the following
operating conditions like:
–– Heavy duty starting
–– Increased switching frequency
–– Single phase operation
–– Phase unbalance
–– High ambient temperature
–– Insufficient cooling
–– Breaking operation
Therefore the consequences from overheating like abrasion as
well as electrical failures can be prevented.
The direct measuring principle is carried out by a combination
of the thermistor motor protection relay and 3 PTC sensors
which are installed directly in the motor by the manufacturer. Those 3 PTC sensors are placed directly at the thermal
hotspots, the motor windings.

Monitoring the motor
The thermistor motor protection relay measures the resistance
of the PTC sensors which reflects the internal motor temperature permanently.
If the temperature in the motor windings rises excessively and
reaches the nominal response temperature (NRT), the thermistor motor protection relay detects this situation and the
output relay switches off.
By doing so the motor contactor gets triggered and switches
off the motor.
CM-MSS functionality video

Characteristics CM-MSS1)
–– Different types of contacts available
–– 1 x 2 c/o (SPDT) contacts
–– 2 x 1 c/o (SPDT) contact
–– 1 n/o and 1 n/c contact
–– 1 or 2 measuring circuits
–– Different types of reset functions
–– Automatic
–– Manual
–– Remote
–– Rated control supply voltages
–– 24 V AC/DC
–– 24-240 V AC/DC
–– 110-130 V AC, 220-240 V AC
–– Approvals / Marks

Features 1)
– – Additional functions:
–– Dynamic interrupted wire detection
–– Short-circuit monitoring of the sensor circuit
–– Non-volatile fault storage
–– Single or sum evaluation
– – Easy configuration via DIP switches
– – LEDs to distinguish between different failure causes
– – Screw connection technology or Easy Connect Technology
available
– – Test/Reset button available

A C R K E I1) / a b

Characteristics CM-MSE
–– Auto reset
–– Connection of several sensors (max. 6 sensors
connected in series)
–– Monitoring of bimetals
–– 1 n/o contact
–– Excellenct cost / performance ratio

2/87 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

1)

Depending on device the characteristics vary, for detailled overview see „Selection
table CM-MSx range“ on page 89.

Thermistor motor protection relays
Operating controls

1 Test / Reset button
Reset - only possible if measured value < switch-on resistance
2 Indication of operational states with LEDs
U: green LED - Status indication of control supply voltage V
1

Control supply voltage applied
F: red LED - Fault message
R: yellow LED - Status indication of the output relay

2

i Single evaluation 2 x 1 c/o (SPDT) contact
j Accumulative evaluation 1 x 2 c/o (SPDT) contacts
y Short-circuit detection de-activated
x Short-circuit detection activated
f Non-volatile fault storage activated
e Non-volatile fault storage de-activated

2CDC 253 001 F0015

3

3 DIP switches

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/88

2

Order code
1SVR550805R9300

1SVR550800R9300

1SVR550801R9300

1SVR740720R1400

1SVR730720R1400

1SVR740700R0100

1SVR730700R0100

1SVR740700R2100

1SVR730700R2100

1SVR740722R1400

1SVR730722R1400

1SVR740700R0200

1SVR730700R0200

1SVR740700R2200

1SVR730700R2200

1SVR740712R1400

1SVR730712R1400

1SVR740712R0200

1SVR730712R0200

1SVR740712R2200

1SVR730712R2200

1SVR740712R1200

1SVR730712R1200

1SVR740712R1300

1SVR730712R1300

CM-MSE

CM-MSE

CM-MSS.11P

CM-MSS.11S

CM-MSS.12P

CM-MSS.12S

CM-MSS.13P

CM-MSS.13S

CM-MSS.21P

CM-MSS.21S

CM-MSS.22P

CM-MSS.22S

CM-MSS.23P

CM-MSS.23S

CM-MSS.31P

CM-MSS.31S

CM-MSS.32P

CM-MSS.32S

CM-MSS.33P

CM-MSS.33S

CM-MSS.41P

CM-MSS.41S

CM-MSS.51P

CM-MSS.51S

2

Type
CM-MSE

Thermistor motor protection relays
Selection table CM-MSx range

1

1

n
1

n
1

1

1

1

1

n
1

n
1

1

1

1

1

n
1

n
1

n
1

n
1

n
1

n
1

n
1

n
1

n
2

n
2

Characteristics
ATEX approval
Number of sensor circuits

1

Single or sum evaluation
Number of LEDs

3

3

2

2

2

2

3

3

2

2

2

2

3

3

3

3

3

3

3

3

n
3

n
3

n

n

n

n
n

n

n

n

n

n

n

n

n

n

n

n

Contacts
1 c/o (SPDT) contact
2 c/o (SPDT) contacts
1 n/o

n

n

n

1 n/c and 1 n/o

n

n

n

n

n

n

2 x 1 c/o or 1 x 2 c/o contacts, configurable
Reset
Manual

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Remote

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Auto

n

n

n

n

n

n

n

n

n

n

n

n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 1) n 2) n 2)

Test button

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Functions
Short-circuit detection

n

n

n

n

n

n

n

n

n

n

n

n

Short-circuit detection, configurable
Dynamic interrupted wire detection

n

n

n

n

n

n

Non-volatile fault storage

n

n

n

n

n

n

Non-volatile fault storage, configurable
Rated control supply voltage US
24 V AC
110-130 V AC
220-240 V AC
24-240 V AC/DC

n
n
n
n

n

24 V AC/DC

n
n

n

n

110-130 V AC, 220-240 V AC

n
n

n

n

n

n

n
n

n

n

n

n

Connection type
Push-in terminals
Double-chamber cage connection terminals
1)
2)

n

n
n

n
n

For automatic reset, connect terminals S1 to T2.
For automatic reset, connect terminals S1 to 1T2/2T2.

2/89 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

n
n

n
n

n
n

n
n

n
n

n
n

n
n

n
n

n

Thermistor motor protection relays
Ordering details
Description
The thermistor motor protection relays CM-MSx are used to control motors equipped with
PTC temperature sensors. The PTC temperature sensors are incorporated in the motor windings to measure the motor heating. This enables direct control and evaluation of various operating conditions. Depending on the products also ATEX approvals for use in hazardous areas
are availabe.
ABB also offers PTC temperature sensors C011 (according to DIN 44081) which are suitable
for embedding in motor windings.
Ordering details CM-MSx

2CDC 251 014 V0014

Rated control Output
supply
voltage

CM-MSS.51S

Function

24 V AC
110-130 V AC

1 n/o

Autoreset

220-240 V AC
24-240 V AC/DC

1 n/c, 1 n/o

Autoreset, dynamic
interrupted wire detection,
non-volatile fault storage,
ATEX approval

24 V AC/DC

1 c/o (SPDT)

Autoreset

110-130 V AC,
220-240 V AC

1 c/o (SPDT)

Autoreset

24-240 V AC/DC

1 n/c, 1 n/o

Autoreset, dynamic
interrupted wire detection,
non-volatile fault storage,
short-circuit detection,
ATEX approval

24 V AC/DC

2 c/o (SPDT)

Auto, manual or remote reset

110-130 V AC,
220-240 V AC

2 c/o (SPDT)

Auto, manual or remote reset

24-240 V AC/DC

1 n/c, 1 n/o

Auto, manual or remote reset,
dynamic interrupted wire
detection, non-volatile fault
storage, short-circuit detection,
ATEX approval

24 V AC/DC

2 c/o (SPDT)

110-130 V AC,
220-240 V AC

2 c/o (SPDT)

Auto, manual or remote
reset, dynamic interrupted
wire detection, short-circuit
detection, ATEX approval

2 c/o (SPDT)

Auto, manual or remote reset,
dynamic interrupted wire
detection, non-volatile fault
storage, short-circuit detection,
ATEX approval

2x1 c/o or,
1x2 c/o

Auto, manual or remote reset,
dynamic interrupted wire
detection, non-volatile fault
storage, short-circuit detection,
accumulative evaluation,
ATEX approval

24-240 V AC/DC

Type

Order code

Price

Weight
(1 pce)

1 pce

kg (lb)

CM-MSE

1SVR550805R9300

0.11 (0.24)

CM-MSE

1SVR550800R9300

0.11 (0.24)

CM-MSE

1SVR550801R9300

CM-MSS.11P

1SVR740720R1400

CM-MSS.11S

1SVR730720R1400

CM-MSS.12P

1SVR740700R0100

CM-MSS.12S

1SVR730700R0100

CM-MSS.13P

1SVR740700R2100

CM-MSS.13S

1SVR730700R2100

CM-MSS.21P

1SVR740722R1400

0.11 (0.24)
0.119
(0.263)
0.127
(0.280)
0.105
(0.231)
0.113
(0.249)
0.147
(0.324)
0.155
(0.342)

CM-MSS.21S

1SVR730722R1400

0.126
(0.278)

CM-MSS.22P

1SVR740700R0200

CM-MSS.22S

1SVR730700R0200

CM-MSS.23P

1SVR740700R2200

CM-MSS.23S

1SVR730700R2200

CM-MSS.31P

1SVR740712R1400

0.121
(0.267)
0.132
(0.291)
0.163
(0.359)
0.174
(0.384)

CM-MSS.31S

1SVR730712R1400

0.128
(0.282)

CM-MSS.32P

1SVR740712R0200

CM-MSS.32S

1SVR730712R0200

CM-MSS.33P

1SVR740712R2200

CM-MSS.33S

1SVR730712R2200

CM-MSS.41P

1SVR740712R1200

0.120
(0.265)
0.130
(0.287)
0.162
(0.357)
0.172
(0.379)

CM-MSS.41S

1SVR730712R1200

CM-MSS.51P

1SVR740712R1300

CM-MSS.51S

1SVR730712R1300

0.118
(0.260)

0.120
(0.265)

0.130
(0.287)
0.141
(0.311)
0.135
(0.298)
0.145
(0.320)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/90

2

Thermistor motor protection relays
Ordering details - PTC temperature sensors C011

1SVC 110 000 F0531

2

Temperature sensor characteristics

RPTC
[]
104

103

101

1)

TNF - 20 K
TNF - 5 K
TNF
TNF + 5 K
TNF + 15 K

-20 °C

TPTC [°C]

2CDC 252 068 F0208

102

Temperature sensor C011, standard
version acc. to DIN 44081
2)
Triple temperature sensor C011-3

Description
The PTC temperature sensors (temperature-dependent with positive temperature coefficient)
are selected by the manufacturer of the motor depending on:
– – the motor insulation class according to IEC/EN 60034-11,
– – the special characteristics of the motor, such as the conductor cross-section of the windings, the permissible overload factor etc.
– – special conditions prescribed by the user, such as the permissible ambient temperature,
risks resulting from locked rotor, extent of permitted overload etc.
One temperature sensor must be embedded in each phase winding. For instance, in case of
three-phase squirrel cage motors, three sensors are embedded in the stator windings. For
pole-changing motors with one winding (Dahlander connection), 3 sensors are also sufficient.
Pole-changing motors with two windings, however, require The sensors are suitable for embedding in motor windings with rated operating voltages of up to 600 V AC. Conductor length:
500 mm per sensor. A 14 V varistor can be connected in parallel to protect the sensors from
overvoltage. Due to their characteristics, the thermistor motor protection relays can also be
used with PTC temperature sensors of other manufacturers which comply with DIN 44 081
and DIN 44 082 6 sensors.
If an additional warning is required before the motor is switched off, separate sensors for a
correspon­d ingly lower temperature must be embedded in the winding. They have to be connected to a second control unit.
Ordering details
Rated response
temperature TNF
70 °C
80 °C
90 °C
100 °C
110 °C
120 °C
130 °C
140 °C
150 °C
160 °C
170 °C
150 °C

Color coding

Type

Order code

white-brown
white-white
green-green
red-red
brown-brown
gray-gray
blue-blue
white-blue
black-black
blue-red
white-green
black-black

C011-701)
C011-801)
C011-901)
C011-1001)
C011-1101)
C011-1201)
C011-1301)
C011-1401)
C011-1501)
C011-1601)
C011-1701)
C011-3-1502)

Price

Weight
(1 pce)
kg (lb)
0.02 (0.044)
0.02 (0.044)
0.02 (0.044)
0.02 (0.044)
0.02 (0.044)
0.02 (0.044)
0.02 (0.044)
0.02 (0.044)
0.02 (0.044)
0.02 (0.044)
0.02 (0.044)
0.05 (0.11)

1 pce
GHC0110003R0001
GHC0110003R0002
GHC0110003R0003
GHC0110003R0004
GHC0110003R0005
GHC0110003R0006
GHC0110003R0007
GHC0110003R0011
GHC0110003R0008
GHC0110003R0009
GHC0110003R0010
GHC0110033R0008

Technical data
Characteristic data
Cold-state resistance
Warm-state resistance ± 5 up to 6 K
of rated
response temperature T NF
Thermal time constant, sensor open 1)
Permitted ambient temperature

Sensor type C011
50 -100 q at 25 °C
10 000 q
<5s
+180 °C

Rated response tempera-

PTC resistance R

ture w tolerance TNF w iTNF

from -20 °C to TNF
- 20 K

70 w5 °C
80 w5 °C
90 w5 °C
100 w5 °C
110 w5 °C
120 w5 °C
130 w5 °C
140 w5 °C
150 w5 °C
160 w5 °C
170 w7 °C
1)
2)

m 100 q

Not embedded in windings.
For triple temperature sensor take values x 3.

2/91 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

PTC resistance R2) at PTC temperatures of:
TNF + 15 K
TNF - iTNF
TNF + iTNF
(UPTC m 2.5 V)

(UPTC m 7.5 V)

(UPTC m 2.5 V)

m 570 q

M 570 q

-

m 550 q

M 1330 q

M 4000 q

m 570 q

M 570 q

-

Thermistor motor protection relays
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
Supply circuit - Input circuit

CM-MSS.x1

Rated control supply voltage U s

CM-MSS.x2

CM-MSS.x3

A1-A2 24-240 V AC/DC

24 V AC/DC

220-240 V AC

A2-A3 -

-

110-130 V AC

Rated control supply voltage U s tolerance

-15...+10 %

Rated frequency

15-400 Hz

50-60 Hz

Electrical insulation between supply circuit and measuring circuit

yes

no

Power failure buffering time

20 ms

yes

Supply circuit - Measuring circuit / Sensor circuit
Number of circuits

1 (CM-MSS.51: 2)

Sensor type

PTC type A (DIN/EN 44081, DIN/EN 44082)

Max. total resistance of sensors connected in series, cold state

< 750

Overtemperature
monitoring

W

switch-off resistance (relay de-energizes) 2.83 kW w 1% (CM-MSS.12 /.13 /.22 /.23: 2.7 kW w 5%)
switch-on resistance (relay energizes) 1.1 kW w 1% (CM-MSS.12 /.13 /.22 /.23: 1.2 kW w 5%)

Maximum voltage in sensor circuit

1.33 kW 2.5 V
4 kW 3.7 V
y kW 5.5 V
3.7 mA

Maximum current in sensor circuit
Maximum sensor cable length

2 x 100 m at 0.75 mm 2, 2 x 400 m at 2.5 mm 2

Accuracy within the rated control supply voltage tolerance

0.50 % (CM-MSS.12 /.13 /.22 /.23: 5 %)

Accuracy within the temperature range

0.01 %/K (CM-MSS.12 /.13 /.22 /.23: 0.5 %/K)

Repeat accuracy (constant parameters)

on request

Reaction time of the safety function

< 100 ms

Hardware fault tolerance (HFT)

0

Control circuit
Control function

see „Selection table CM-MSx range“ on page 89

Maximum no-load voltage

5.5 V

Max. current

0.6 mA (CM-MSS.12 /.13 /.22 /.23: 1.2 mA)

Maximum cable length

2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm²

Indication of operational states
Control supply voltage

U LED green

Relay status

R LED yellow

Fault message

F LED red

Output circuit
Kind of output

see „Selection table CM-MSx range“ on page 89

Operating principle

closed-circuit principle

Contact material

AgNi alloy, Cd free

Rated operational voltage U e (IEC/EN 60947-1)

250 V AC

Minimum switching voltage / Minimum switching current

24 V / 10 mA

Maximum switching voltage / Maximum switching current

see data sheet

Rated operating current I e
(IEC/EN 60947-5-1)

AC-12 (resistive) at 230 V 4 A
AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A
DC-13 (inductive) at 24 V 2 A

AC Rating (UL 508)

utilization category (Control Circuit Rating Code) B 300
maximum rated operational voltage 250 V AC
maximum continuous thermal current at B 300 4 A
maximum making/breaking apparent power at B 300 3600/360 VA

Mechanical lifetime
Electrical lifetime
Maximum fuse rating to achieve short-circuit
protection

30 x 10 6 switching cycles
at AC12, 230 V AC, 4 A 0.1 x 10 6 switching cycles
n/c contact 10 A fast-acting (CM-MSS.12, CM-MSS.13, CM-MSS.51: 6 A)
n/o contact 10 A fast-acting

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/92

2

Thermistor motor protection relays
Technical data - CM-MSS
General data
MTBF

on request

Duty time

2

100 %

Dimensions (W x H x D)

product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)

Weight

see „Ordering details“ on page 90

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units

vertical 10 mm (0.394 in) if switching current > 2 A
horizontal 10 mm (0.394 in) if switching current > 2 A

Material of housing

UL 94 V-0

Degree of protection

housing IP50
terminals IP20

Electrical connection

Screw connection technology

Wire size

Easy Connect Technology (push-in)

fine‑strand with(out) wire end 1 x 0.5-2.5 mm (1 x 20-14 AWG)
ferrule 2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)

2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)

rigid 1 x 0.5-4 mm 2 (1 x 20-12 AWG)
2 x 0.5-2.5 mm2 (2 x 20-14 AWG)

2 x 0.5-1.5 mm 2 (2 x 20-16 AWG)

2

Stripping length

8 mm (0.32 in)

Tightening torque

0.6-0.8 Nm (5.31-7.08 lb.in)

-

Wire end ferrule

according to DIN 46228-1-A,
DIN 46228-4-E

-

Environmental data
Ambient temperature ranges

operation -25 °C...+60 °C
storage -40 °C...+85 °C

Damp heat, cyclic (IEC/EN 60068-2-30)

6 x 24 h cycle, 55 °C, 95 % RH

Climatic category (IEC/EN 60721-3-3)

3K5 (no condensation, no ice formation)

Vibration, sinusoidal (IEC/EN 60255-21-1)

Class 2

Shock (IEC/EN 60255-21-2)

Class 2

Isolation data
Rated insulation voltage
U i (IEC/EN 60947-1,
IEC/EN 60664-1)

Supply circuit / Measuring circuit1) 300 V AC (CM-MSS.x2: n/a)
Supply circuit / Output circuits 300 V AC
Measuring circuit1) / Output circuits 300 V AC
Output circuit 1 / Output circuit 2 300 V AC

Rated impulse
withstand voltage
U imp (IEC/EN 60947-1,
IEC/EN 60664-1)
Basic insulation
(IEC/EN 60664-1)

Supply circuit / Measuring circuit1) 4 kV / 6 kV (CM-MSS.x2: n/a)
Supply circuit / Output circuits 4 kV / 6 kV
Measuring circuit1) / Output circuits 4 kV / 6 kV
Output circuit 1 / Output circuit 2 4 kV
Supply circuit / Measuring circuit1) 600 V AC (CM-MSS.x2: n/a)
Supply circuit / Output circuits 600 V AC
Measuring circuit1) / Output circuits 600 V AC
Output circuit 1 / Output circuit 2 300 V AC

Test voltage, routine
test (IEC/EN 60255-27,
IEC/EN 61010-1)
Test voltage, type test
(IEC/EN 60255-27)

Supply circuit / Measuring circuit1) 2.5 kV, 50 Hz, 1 min. (CM-MSS.x2: n/a)
Supply circuit / Output circuits 2.5 kV, 50 Hz, 1 min.
Measuring circuit1) / Output circuits 2.5 kV, 50 Hz, 1 min.
Supply circuit / Measuring circuit1) 6 kV / 1.2 - 50 μs (CM-MSS.x2: n/a)
Supply circuit / Output circuits 6 kV / 1.2 - 50 μs
Measuring circuit1) / Output circuits 6 kV / 1.2 - 50 μs
Output circuit 1 / Output circuit 2 6 kV / 1.2 - 50 μs

Protective separation
(IEC/EN 61140,
IEC/EN 50178)

Supply circuit / Measuring circuit1) yes, up to 300 V
Supply circuit / Output circuits yes (CM-MSS.x2: n/a)
Measuring circuit1) / Output circuits yes
Output circuit 1 / Output circuit 2 no

Pollution degree (IEC/EN 60664-1)

3

Overvoltage category (IEC/EN 60664-1)

III

1)

Potential of measuring circuit = Potential of control circuit

2/93 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Thermistor motor protection relays
Technical data - CM-MSS
Standards
Product standard

IEC/EN 60255-1; IEC/EN 60947-8

Low Voltage Directive

2006/95/EC

EMC directive

2004/108/EC

ATEX directive

94/9/EC (only ATEX variants „Selection table CM-MSx range“ on page 89)

RoHS directive

2011/65/EC

Electromagnetic compatibility
Interference immunity to

IEC/EN 61000-6-1, IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 Level 3, 6 kV contact discharge, 8 kV air discharge

radiated, radio-frequency,
electromagnetic field

IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz), 3 V/m (2 GHz), 1 V/m (2.7 GHz)

electrical fast transient / burst

IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz

surge

IEC/EN 61000-4-5 Level 3, Installation class 3, supply circuit and measuring circuit 1 kV L-L,
2 kV L-N

conducted disturbances,
induced by radio-frequency
fields

IEC/EN 61000-4-6 Level 3, 0.15-80 MHz, 10 V, 80 % AM (1kHz)

voltage dips, short
interruptions and voltage
variations

IEC/EN 61000-4-11 Class 3

harmonics and interharmonics

IEC/EN 61000-4-13 Class 3

Additional interference immunity according to product standard EN
60255-1 (reference on EN 60255-26_2011)
radiated, radio-frequency,
electromagnetic field

IEC/EN 61000-4-3 10 V/m (80 MHz - 3 GHz)

conducted disturbances,
induced by radio-frequency
fields

IEC/EN 61000-4-6 10 V at stated frequencies

damped oscillatory waves
Interference emissions

IEC/EN 61000-4-18 Signal lines, symmetric coupling: 1 kV peak voltage
Power supply, asymmetric coupling: 2.5 kV peak voltage
IEC/EN 61000-6-3, IEC/EN 61000-6-4

high-frequency radiated

IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

high-frequency radiated

Germanischer Lloyd increased requirements in the emergency call frequency band

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/94

2

Thermistor motor protection relays
Technical data - CM-MSE
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated

2

Supply circuit - Input circuit
Rated control supply voltage U s power consumption

CM-MSE
1SVR550805R9300 24 V AC approx. 1.5 A
1SVR550800R9300 110-130 V AC approx. 1.5 A
1SVR550801R9300 220-240 V AC approx. 1.5 A

Rated control supply voltage U s tolerance

-15...+10 %

Rated frequency
Measuring circuit
Monitoring function
Number of sensor circuits
Sensor circuit
Temperature threshold (relay de-energizes)
Temperature hysteresis (relay energizes)
Short-circuit threshold (relay de-energizes)
Short-circuit hysteresis (relay energizes)
Maximum total resistance of sensors connected in series (cold state)
Maximum sensor cable length for short-circuit detection
Response time
Output circuit
Kind of output

50-60 Hz
T1-T2 temperature monitoring by means of PTC sensors
1
2.7-3.7 kW
1.7-2.3 kW
<18 W
>45 W
1.5 kW
2 x 100 m at 0.75 mm 2, 2 x 400 m at 2.5 mm 2
<100 ms
13-14 1 n/o contact

Operational principle
Contact material
Rated voltage
Maximum switching voltage
Rated operating current I e
(IEC/EN 60947-5-1)

closed-circuit principle (output relay de-energizes if the measured
value exceeds/drops below the adjusted threshold)
AgCdO

VDE 0110, IEC 664-1, IEC 60947-1 250 V
250 V
AC-12 (resistive) at 230 V 4 A
AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A
DC-13 (inductive) at 24 V 2 A
AC Rating (UL 508)
utilization category (Control Circuit Rating Code) B 300
maximum rated operational voltage 300 V AC
maximum continuous thermal current at B 300 5 A
maximum making/breaking apparent power at B 300 3600/360 VA
Mechanical lifetime
30 x 10 6 switching cycles
Electrical lifetime
at AC12, 230 V AC, 4 A 0.1 x 10 6 switching cycles
Maximum fuse rating to achieve short-circuit
n/c contact 10 A fast-acting
protection
n/o contact 10 A fast-acting
General data
Dimensions (W x H x D)
22.5 x 78 x 78.5 mm (0.89 x 3.07 x 3.09 in)
Duty time
100 %
Weight
approx. 0.11 kg (0.24 lb)
Mounting position
any
Degree of protection
housing / terminals IP50 / IP20
Ambient temperature range
operation -20...+60 °C
storage -40...+85 °C
Mounting
DIN rail (IEC/EN 60715)
Electrical connection
Wire size
fine strand with wire end ferrule 2 x 1.5 mm 2 (2 x 16 AWG)
fine strand without wire end ferrule 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG)
rigid 2 x 1-1.5 mm 2 (2 x 18-16 AWG)
Stripping length
2 x 0.75-1.5 mm 2 (2 x 18-16 AWG)
Tightening torque
0.6-0.8 Nm (5.31-7.08 lb.in)
Standards
Product standard
IEC 255-6, EN 60255-6
Low Voltage Directive
2006/95/EC
EMC Directive
2004/108/EC, 91/263/EEC, 92/31/EEC, 93/68/EEC, 93/67/EEC
Electromagnetic compatibility
electrostatic discharge
IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient /burst
IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)
surge
IEC/EN 61000-4-5 Level 3/4 (1/2 kV)
conducted disturbances, induced by radioIEC/EN 61000-4-6 Level 3 (10 V)
frequency fields
Operational reliability (IEC 68-2-6)
6g
Resistance to vibration (IEC 68-2-6)
10 g
Environmental testing (IEC 68-2-30)
24 h cycle time, 55 °C, 93 % rel., 96 h
Electromagnetic compatibility
Rated voltage between supply, measuring and output circuit
250 V
Rated impulse withstand voltage between all isolated circuits
4 kV / 1.2 - 50 μs
Test voltage between all isolated circuits
2.5 kV, 50 Hz, 1 min.
Pollution degree
3
Overvoltage category
III
2/95 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Thermistor motor protection relays
Notes

2

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/96

Thermistor motor protection relays
Connection diagrams

14

22

T1

ϑ

A1
A3

T1
11

A1

A2

13

14

21

22

A2

T2

A2

14

12 14

12

A2

Control supply voltage

A1 – A2

Control supply voltage

13 – 14

n/o contact

11 – 12/14

c/o contact

21 – 22

n/c contact

T1 – T2

Measuring circuit

T1 – T2

Measuring circuit

T1

A1

21
T1
11

A1
A3

ϑ
T2

S1

A2

24
14

A1 – A2
11 – 12/14
21 – 22/24
S1 – T2
(jumpered)
T1 – T2

12 14

22
12

22

24

S1
A2

11
T2

T1 A1 A3

21

2CDC 252 019 F0014

S1

11
T2

CM-MSS.23, CM-MSS.33

T1

11

11

24
14

Control supply
voltage 24 V AC/DC
1st c/o (SPDT)
contact
2nd c/o (SPDT)
contact
Automatic reset

A1 – A2

Measuring circuit

21 – 22/24

A2 – A3

11 – 12/14

S1 – T2
(jumpered)
T1 – T2

12 14

22
12

A2

12

11 – 12/14

c/o contact

T1 – T2

Measuring circuit

CM-MSS.51

1T1

Control
supply voltage
220-240 V AC
Control supply
voltage 110-130
V AC
1st c/o (SPDT)
contact
2nd c/o (SPDT)
contact
Automatic reset
Measuring
circuit

Control supply voltage
220-240 V AC
Control supply voltage
110-130 V AC

21

S1
A2

A2

A2 – A3

A1
1T1

22 24

12 14

A1 – A2

S1

A2

S1

14

21
T1

ϑ
T2

T2

2CDC 252 021 F0014

A1

A1
S1

T1

ϑ

A1 – A2

CM-MSS.22, CM-MSS.32,
CM-MSS.41

11
T2

T1 A1 A3

ϑ
2CDC 252 018 F0014

T2

11
T2

11

ϑ

1T2/2T2

2T1

S1

A2 12

24
14

A1

14

A2

13

21
T1
22

ϑ
T2

14

21

22

A2

A1 – A2

Control supply voltage

13 – 14

n/o contact

21 – 22

n/c contact

S1 – T2
(jumpered)

Automatic reset

T1 – T2

Measuring circuit

CM-MSE

11
1T2/2T2
A1

13
T2

2CDC 252 047 F0014

A1

A1

CM-MSS.31

14

A1

A1
T1

21

T1

T2

A1

13

A2

14

ϑ

ϑ

1T2/2T2

22
12

21
2T1

A2 22

S1
A2

24

T2

13

14

A2

1SVC 110 000 F0140

T1

21
T1

2CDC 252 022 F0014

2

13
T2

CM-MSS.13

2CDC 252 020 F0014

A1

CM-MSS.12

2CDC 252 017 F0014

CM-MSS.11, CM-MSS.21

A1 – A2

Control
supply voltage
220-240 V AC

A1 – A2

Control supply voltage
24 V AC

T1-T2

Sensor circuit

11 – 12/14

1st c/o (SPDT)
contact

13-14

21 – 22/24

2nd c/o (SPDT)
contact

Output contact Closed circuit principle

S1 – 1T2/2T2
(jumpered)

Automatic reset

1T1 – 1T2/2T2

Measuring circuit 1

2T1 – 1T2/2T2

Measuring circuit 2

2/97 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Thermistor motor protection relays
Circuit diagram
CM-MSS.11, CM-MSS.21

CM-MSS.12

V+

V+
A1

CM-MSS.13
V+
A1

14

A1 or A3

22

11

11

2
T1

T1
M 3~

M 3~
T2

t

T2

A2
V-

CM-MSS.22

t
14
12

A2
V-

2CDC 253 024 F0014

13

2CDC 253 023 F0014

t
21

CM-MSS.23

V+

12

A2
V-

CM-MSS.31
V+

V+
A1

14

A1 or A3

11
21

A1

11

T1

T1

T1

T2

T2

T2
t

22
14

Reset

12
A2

V-

24
22
14

Reset
S1

12
A2

V-

2CDC 253 027 F0014

24

2CDC 253 026 F0014

t

S1

µC

M 3~

M 3~

t

21
13
Test /
Reset
S1

CM-MSS.32, CM-MSS.41

CM-MSS.33

CM-MSS.51

V+

V+
A1 or A3

11
21

A2

V-

V+
A1

14
22

21

M 3~

2CDC 253 025 F0014

T2

A1

11

2CDC 253 028 F0014

µC

M 3~

T1

11
21

21
1T1
M 3~

T1

T1
µC

1T2/
2T2

µC

24
22
Test /
Reset

14
12
A2

V-

t
24
22
Test /
Reset

14
S1

V-

12
A2

M 3~

24
22

2T1
t

14
12

Test /
Reset
S1

2CDC 253 016 F0014

T2

2CDC 253 015 F0014

T2
t

S1

t
µC

M 3~

2CDC 253 029 F0014

M 3~

A2

V-

1SVC 110 000 F0141

CM-MSE

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/98

Temperature monitoring relays
Product group picture

2

2/99 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Temperature monitoring relays
Table of contents
Temperature monitoring relays
Benefits and advantages, Applications
Operating controls

2/99
2/100

Selection

2/101

Ordering details

2/102

Function diagrams

2/103

Overview, Functional description and diagrams

2/104

Connection diagrams, Resistance thermometer sensors

2/105

Technical data - CM-TCS.xx

2/106

Technical data - C51x

2/108

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/100

2

Temperature monitoring relays
Benefits and advantages, Applications

2

Overview
The temperature monitoring relays can be used for temperature measurement in solid, liquid and gaseous media. The
temperature is acquired by the sensor in the medium, evaluated by the device and monitored to determine whether it is
within an operating range (range monitoring function) or has
exceeded or fallen below a threshold.

Functional description
The temperature monitoring relays CM-TCS monitor overtemperature, undertemperature, or temperatures between two
threshold values (window monitoring) with PT100 sensor. As
soon as the temperature falls below or exceeds the threshold
value the output relays change their positions according to
the configured functionality and the front-face LEDs display
the current status. Regardless of the selected configuration,
the device is monitoring its measuring circuit for interrupted
wires or short‑circuits.

Characteristics CM-TCS
–– Adjustable sensor type: PT100
–– Functionality like overtemperature monitoring, undertemperature monitoring, temperature window monitoring
configurable
–– All configurations and adjustments by front-face operating
elements
–– Precise adjustment with direct reading scales
–– One or two threshold values
–– Hysteresis 2...20 % adjustable
–– Operating temperature range -40...+60 °C
–– 1 x 2 c/o or 2 x 1 c/o configurable
–– Open- or closed-circuit principle configurable
–– Short-circuit monitoring and interrupted wire detection
–– 22.5 mm (0.89 in) width
–– LEDs for status indication

Characteristics C512 + C513
– – Adjustable sensor types: PT100, PT1000, KTY83, KTY84,
NTC-B57227-K333-A1
– – Measuring principle for 2-wire and 3-wire sensors
– – Temperature monitor for 1-3 sensor circuits
– – Adjustable over-, undertemperature monitoring or range
monitoring function
– – 2 thresholds
– – Hysteresis for both thresholds (1-99 Kelvin)
– – Adjustable time delay from 0-999 s affects to both thresholds
– – Storage function selectable via external signal (Y1-Y2)
– – Non volatile storage of parameter settings
– – 1 n/o (for wire-break and short-circuit detection) and 2 c/o
– – Multifunctional digital display
– – 3 LEDs for status indication
– – Open- or closed-circuit principle selectable
– – 45 mm wide housing with 24 terminals
C512
– – Temperature monitor for 1 sensor circuit
C513
– – Temperature monitor for 1-3 sensor circuits
– – In the 3-sensor version the status of the single sensors
is displayed if the temperature exceeds or falls below the
threshold. This way it can be easily determined which one
of the connected sensors has exceeded or dropped below
either one or both threshold values.

2/101 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Temperature monitoring relays
Operating controls

1 Adjustment of the hysteresis for threshold value t1
2 Adjustment of the threshold value t1
3 Indication of operational states

1

U: green LED – status indication of control supply voltage
t: red LED – fault message, state of measuring input
R: yellow LED – status indication of the output relays

4 Adjustment of the hysteresis for threshold value t2

2

5 Adjustment of the threshold value t2
6 DIP switch functions / marker label (on page 2/104)

3
4

Overtemperature monitoring
Undertemperature monitoring
Temperature window monitoring activated
Temperature window monitoring de-activated
Closed-circuit principle
Open-circuit principle
2 x 1 c/o (SPDT) contact
1 x 2 c/o (SPDT) contacts

2CDC 253 019 F0013

5

p
q
r
s
g
h
i
j

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/102

2

1SVR 730 740 R0300

1SVR 740 740 R0300

1SAR 700 100 R0005

1SAR 700 110 R0010

1SAR 700 110 R0010

CM-TCS.13S

CM-TCS.13P

C512-24

C512-W

C513-W

1SVR 730 740 R0200
CM-TCS.12S

1SVR 740 740 R9300

1SVR 740 740 R9200
CM-TCS.22P

CM-TCS.23P

1SVR 730 740 R9200
CM-TCS.22S

1SVR 730 740 R9300

1SVR 740 740 R0100
CM-TCS.11P

1SVR 740 740 R0200

1SVR 730 740 R0100

CM-TCS.23S

1SVR 740 740 R9100

J

CM-TCS.11S

J

CM-TCS.21P

J

1SVR 730 740 R9100

J

CM-TCS.21S

24 V AC/DC

Order number
Rated control supply voltage Us

Type

2

CM-TCS.12P

Temperature monitoring relays
Selection

J

J

J

J
J

J

24-240 V AC/DC

J

J

J

J

J
J

J

J

J

J

Technology
analogue

J

J

J

J

J

J

J

J

J

J

digital
Sensor circuits (2 or 3 wire)

number of temperature sensors
number of thresholds

1

1

1

1

1

1

1

1

1

1

1

1

1

1

3

2

2

2

2

2

2

2

2

2

2

2

2

2

2

3

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

Sensor type
PT100
PT100, KTY83, KTY84, NTC, PT1000
Measuring temperature range
-50...+50 °C

J

J

J

J
J

0...+100 °C

J

J

J
J

0...+200 °C

J

J

J

-50...+500 °C
Monitoring function
overtemperature

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

undertemperature

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

window temperature
Operating principle
open or closed principle
Output contacts
n/o

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

1

1

1

c/o

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2/103 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Temperature monitoring relays
Ordering details
Description
Acquisition, messaging and regulation of temperatures of solid, liquid and gaseous media in
processes and machines via PT100, PT1000, KTY83, KTY84 or NTC sensors.
ABB offers different temperature monitoring relays to meet the needs of your application:
Ordering details - Temperature monitoring relays PT100 sensors, 2 or 3 wire connection,
2 thresholds adjustable
Rated control
supply voltage

Measuring
range

2CDC 251 031 V0012

-50...+50 °C
24-240 V AC/DC

0...+100 °C
0...+200 °C

CM-TCS

-50...+50 °C
24 V AC/DC

0...+100 °C
0...+200 °C

Type

Order code

Price

Weight
(1 pce)

1 pce

kg (lb)

CM-TCS.11S

1SVR730740R0100

0.151 (0.333)

CM-TCS.11P

1SVR740740R0100

0.140 (0.309)

CM-TCS.12S

1SVR730740R0200

0.151 (0.333)

CM-TCS.12P

1SVR740740R0200

0.140 (0.309)

CM-TCS.13S

1SVR730740R0300

0.151 (0.333)

CM-TCS.13P

1SVR740740R0300

0.140 (0.309)

CM-TCS.21S

1SVR730740R9100

0.138 (0.304)

CM-TCS.21P

1SVR740740R9100

0.127 (0.280)

CM-TCS.22S

1SVR730740R9200

0.138 (0.304)

CM-TCS.22P

1SVR740740R9200

0.127 (0.280)

CM-TCS.23S

1SVR730740R9300

0.138 (0.304)

CM-TCS.23P

1SVR740740R9300

0.127 (0.280)

Ordering details - Temperature monitoring relays C51x range with display and digital setup
Rated control
supply voltage

Measuring
range

24 V AC/DC

1SVC 110 000 F0557

24-240 V AC/DC

C512, C513

-50...+500 °C 1)

24-240 V AC/DC

1)

Type 2)

Order code

Price

Weight
(1 pce)

1 pce

kg (lb)

C512-24

1SAR700100R0005

0.32 (0.71)

C512-W

1SAR700100R0010

0.33 (0.73)

C513-W

1SAR700110R0010

0.34 (0.75)

The measuring range depends on the used sensor type:
PT100: -50...+500 °C
PT1000: -50...+500 °C
NTC: +80...+160 °C
(Typ Siemens Matsushita B57272-A333-A1 - 100 °C: 1.8 kW, 25 °C: 32.762 kW)
KTY84: -40...+300 °C
KTY83: -50...+175 °C

Ordering details - Replaceable cover marking for digital devices
Use for

Language

Type

Order code

Price
5 pces

C512

German

C512-D

1SVR700101R0100

C512

English

C512-E

1SVR700102R0100

C513

German

C513-D

1SVR700111R0100

C513

English

C513-E

1SVR700112R0100

Weight
(1 pce)
kg (lb)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/104

2

CM-TCS - Overtemperature monitoring, 1 x 2 c/o contacts j

2CDC 252 008 F0209

Temperature monitoring relays
Function diagrams
A1-A2
Threshold ϑ1
Hysteresis
Measured value
Open-circuit principle

open

11-14
11-12
21-24
21-22
U: green LED
ϑ: red LED
R: yellow LED
Closed-circuit principle

closed

11-14
11-12
21-24
21-22
U: green LED
ϑ: red LED
R: yellow LED

Undertemperature monitoring, 1 x 2 c/o contacts j
With this configuration, settings via t 1 have no influence on the operating function (t 1 disabled).
Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If
the measured value drops below the adjusted threshold value t 2, the output relays energize. If the measured value
exceeds again the adjusted threshold value t 2 plus the adjusted hysteresis, the output relays de-energize.
Closed-circuit principle:
The behavior is inverse to the one with open-circuit principle.

A1-A2
Threshold ϑ1
Hysteresis
Threshold ϑ2
Hysteresis
Measured value
Open-circuit principle

open

11-14
11-12
21-24
21-22
U: green LED
ϑ: red LED
R: yellow LED
Closed-circuit principle

closed

11-14
11-12
21-24
21-22
U: green LED
ϑ: red LED
R: yellow LED

A1-A2

2CDC 252 010 F0209

Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the
measured value exceeds the adjusted threshold value t 2, output relay R2 (prewarning) energizes. If the measured
value exceeds the adjusted threshold value t 1, output relay R1 (final switch-off) energizes.
If the measured value drops again below the adjusted threshold value t 1 minus the adjusted hysteresis, output relay
R1 (final switch-off) de-energizes. If the measured value drops below the adjusted threshold value t 2 minus the
adjusted hysteresis, output relay R2 (prewarning) de-energizes.
Closed-circuit principle:
The behavior is inverse to the one with open-circuit principle.

2CDC 252 009 F0209

Overtemperature monitoring, 2 x 1 c/o contact i

Measured value
Hysteresis
Threshold ϑ2
Open-circuit principle

open

11-14
11-12
21-24
21-22
U: green LED
ϑ: red LED
R: yellow LED
Closed-circuit principle

closed

11-14
11-12
21-24
21-22
U: green LED
ϑ: red LED
R: yellow LED

Temperature window monitoring, 1 x 2 c/o contacts j

Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If
the measured value exceeds the adjusted threshold value t 1 or drops below the adjusted threshold value t 2, the
output relays energize. If the measured value drops again below the adjusted threshold value t 1 minus the adjusted
hysteresis or exceeds again the adjusted threshold value t 2 plus the adjusted hysteresis, the output relays deenergize.
Closed-circuit principle:
The behavior is inverse to the one with open-circuit principle.

A1-A2
Measured value
Hysteresis
Threshold ϑ1
Hysteresis
Threshold ϑ2
Open-circuit principle

open

11-14
11-12
21-24
21-22
U: green LED
ϑ: red LED
R: yellow LED
Closed-circuit principle

closed

11-14
11-12
21-24
21-22
U: green LED
ϑ: red LED
R: yellow LED

A1-A2
Threshold ϑ1
Hysteresis
Measured value
Hysteresis
Threshold ϑ2
Open-circuit principle

open

11-14
11-12
21-24
21-22

2CDC 252 012 F0209

Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the
measured value drops below the adjusted threshold value t 1, output relay R1 (prewarning) energizes. If the measured
value drops below the adjusted threshold value t 2, output relay R2 (final switch-off) energizes.
If the measured value exceeds again the adjusted threshold value t 2 plus the adjusted hysteresis, output relay R2
(final switch-off) de-energizes. If the measured value exceeds the adjusted threshold value t 1 plus the adjusted
hysteresis, output relay R1 (prewarning) de-energizes.
Closed-circuit principle:
The behavior is inverse to the one with open-circuit principle.

2CDC 252 011 F0209

Undertemperature monitoring, 2 x 1 c/o contact i

U: green LED
ϑ: red LED
R: yellow LED
Closed-circuit principle

closed

11-14
11-12
21-24
21-22
U: green LED
ϑ: red LED
R: yellow LED

Temperature window monitoring, 2 x 1 c/o contact i

Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied.
If the measured value exceeds the adjusted threshold value t 1 or drops below the adjusted threshold value t 2, output
relay R1 (> t 1) or R2 (< t 2) respectively energizes.
If the measured value drops again below the adjusted threshold value t 1 minus the adjusted hysteresis or exceeds
again the adjusted threshold value t 2 plus the adjusted hysteresis, output relay R1 (>t 1) or R2 ( 10 W feature a continuously adjustable output voltage. Thus, they can be optimally adapted to
the application, e.g. compensating the voltage drop caused
by a long line length.

3

2CDC 276 032 F0007

2

2CDC 276 033 F0007

1

2CDC 271 027 F0007

3

Characteristics
–– Output voltages 12 V, 24 V DC
–– Adjustable output voltages (devices > 10 W)
–– Output currents 0.42 A / 0.83 A / 1.3 A / 2.1 A / 2.5 A / 4.2 A
–– Power range 10 W, 30 W, 60 W, 100 W
–– Wide range input 100-240 V AC (90-264 V AC, 120-375 V DC)
–– High efficiency of up to 89 %
–– Low power dissipation and low heating
–– Free convection cooling (no forced cooling with ventilators)
–– Ambient temperature range during operation -40 °C...+70 °C
–– Open-circuit, overload and short-circuit stable
–– Integrated input fuse
–– U/I characteristic (fold-forward behaviour at overload – no
switch-off)
–– LEDs for status indication
–– Light-grey housing in RAL 7035
–– Approvals / Marks (depending on device, partly pending):
A, H, R , E / a, b

1

1 OUTPUT ++/‑‑: terminals ‑ output

2

3 Indication of operational states

2 INPUT L, N: terminals ‑ input
DC ON: green LED ‑ output voltage applied
DC LOW: red LED ‑ output voltage too low

4 Circuit diagram
5 OUTPUT Adjust: potentiometer ‑ adjustment of output voltage

3
4

5

3/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-D range
Ordering details
Description

2CDC 271 024 F0007

The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution panels. This range offers devices with
output voltages of 12 V DC and 24 V DC at output currents of 0.42 A to 4.2 A. Thanks to a
high thermal efficiency corresponding to low power and heat dissipation, the devices can be
operated without forced cooling. All devices feature the U/I output characteristic (fold forward
behaviour). All power supply units in the CP-D range are approved according to all relevant
international standards.
Ordering details
Input voltage range

Rated
output voltage /
current

Type

90-264 V AC/ 120-375 V DC

12 V DC / 0.83 A

CP-D 12/0.83

1SVR427041R1000

0.06
(0.13)

90-264 V AC/ 120-375 V DC

12 V DC / 2.1 A

CP-D 12/2.1

1SVR427043R1200

0.19
(0.41)

90-264 V AC/ 120-375 V DC

24 V DC / 0.42 A

CP-D 24/0.42

1SVR427041R0000

0.06
(0.13)

90-264 V AC/ 120-375 V DC

24 V DC / 1.3 A

CP-D 24/1.3

1SVR427043R0100

0.19
(0.41)

90-264 V AC/ 120-375 V DC

24 V DC / 2.5 A

CP-D 24/2.5

1SVR427044R0200

0.25
(0.56)

90-264 V AC/ 120-375 V DC

24 V DC / 4.2 A

CP-D 24/4.2

1SVR427045R0400

0.32
(0.71)

2CDC 271 025 F0007

CP-D 12/0.83, CP-D 24/0.42

Order code

Price
1 pce

Weight
(1 pce)
kg (lb)

2CDC 271 028 F0007

CP-D 12/2.1, CP-D 24/1.3

CP-D 24/2.5

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/10

3

CP-D range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-D 12/0.83

Input circuit - supply circuit
Rated input voltage U in

100-240 V AC

Input voltage range

90-264 V AC / 120-375 V DC

Frequency range AC

3

Typical input current /
typical power consumption
Inrush current limiting

47-63 Hz
at 110 V AC 200 mA / 12.68 W

502 mA / 31.14 W

at 230 V AC 128.3 mA / 13.01 W

277 mA / 31.2 W

at 230 V AC 30 A (max. 3 ms)

50 A (max. 3 ms)

Power failure buffering time

min. 30 ms

Internal input fuse

1 A slow-acting / 250 V AC

Power factor correction (PFC)

no

Indication of operational states
Output voltage

CP-D 12/2.1
L, N

2 A slow-acting / 250 V AC

DC ON: green LED V : output voltage applied
DC LOW: red LED V : output voltage too low

Output circuit
Rated output voltage

12 V DC

+, -

Tolerance of the output voltage

±1 %

Adjustment range of the output voltage

-

12-14 V DC

Rated output power

10 W

25 W

Rated output current I r
Derating of the output current
Maximum
­d eviation
with
Control time

Ta m 60 °C 0.83 A

++, --

2.1 A

60 °C < Ta m 70 °C 2.5 %/°C
load change statical max. 1 %

change of output voltage within the input voltage range max. 1 %

Starting time after applying the supply
voltage
Rise time
Residual ripple and switching peaks

< 1 ms
at I r 1000 ms
at rated load typ. 1 ms
BW = 20 MHz 50 mV

Parallel connection

yes, using CP-D RU

Series connection

yes, to increase voltage

Resistance to reverse feed

18 V / 1 s

Output circuit - No-load, overload and short-circuit behaviour
Characteristic curve of output

U/I characteristic curve

Short-circuit protection

continuous short-circuit stability

Short-circuit behaviour

continuation with output power limiting

Current limiting at short circuit

typ. 1.4 A

Overload protection

output power limiting

Overvoltage protection

15-16.5 V DC

No-load protection

continuous no-load stability

Starting of capacitive loads

unlimited

General data
Efficiency

typ. 78 %

Duty time

100 %

Dimensions (W x H x D)
Weight

18 x 91 x 57.5 mm
(0.71 x 3.58 x 2.26 in)
0.066 kg (0.13 lb)

Material of housing

plastic

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

II

3/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

typ. 5.9 A

typ. 82 %
53 x 91 x 57.5 mm
(2.09 x 3.58 x 2.26 in)
0.196 kg (0.41 lb)

CP-D range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-D 12/0.83

CP-D 12/2.1

Electrical connection - Input circuit / Output circuit
Wire size
fine-strand with wire end ferrule 0.2-1.5 mm 2 (24-16 AWG)

0.2-2.5 mm 2 (24-14 AWG)

rigid 0.2-2.5 mm 2 (26-12 AWG)
4-5 mm (0.16-0.2 in)

0.2-2.5 mm 2 (24-12 AWG)
7 mm (0.28 in)

Stripping length
Tightening torque

0.6 Nm (5 lb.in)

Environmental data
Ambient temperature range

0.7 Nm (6 lb.in)

operation -40…+70 °C
rated load -40…+60 °C
storage -40…+85 °C

Damp heat (cyclic) (IEC/EN 60068-2-30)

4 x 24 cycles, 40 °C, 95 % RH

Vibration (sinusoidal) (IEC/EN 60068-2-6)

50 m/s 2, 10 Hz - 2 kHz

Shock (half-sine) (IEC/EN 60068-2-27)

40 m/s 2, 22 ms

Isolation data
Rated insulation voltage U i

input circuit / output circuit 3 kV AC

Pollution degree

2

Overvoltage category (UL/IEC/EN 60950-1)

ll

Standards
Product standard

EN 61204

Low Voltage Directive

2006/95/EC

EMC Direcitve

2004/108/EC

Electrical safety

UL 508, UL 60950-1, EN 60950-1

Protective low voltage

SELV (EN 60950-1)

Electromagnetic compatibility
Interference immunity to

EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 Level 4 (4 kV / 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 Level 3 (10 V/m)

electrical fast transient/burst

IEC/EN 61000-4-4 Level 4 (4 kV)

surge

IEC/EN 61000-4-5 Level 3 (2 kV L-L)

conducted disturbances, induced by radiofrequency fields
Interference emission

IEC/EN 61000-4-6 Level 3 (10 V)

Level 4 (4 kV / 15 kV)

EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

„Approvals and marks“ on page 3/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/12

3

CP-D range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-D 24/0.42
100-240 V AC

Input voltage range

90-264 V AC /120-375 V DC

Typical input current /
typical power consumption
Inrush current limiting

CP-D 24/4.2

1120 mA / 69.3 W

1800 mA / 117.3 W

47-63 Hz
at 110 V AC 184 mA / 11.62 W

600 mA / 37.92 W

at 230 V AC 120.6 mA / 12 W 344 mA / 38.16 W

660 mA / 70.1 W 900 mA / 114.4 W

at 230 V AC 30 A (max. 3 ms) 50 A (max. 3 ms) 60 A (max. 3 ms)

Power failure buffering time

min. 30 ms

Internal input fuse

1 A slow-acting
/ 250 V AC
no

Power factor correction (PFC)
Indication of operational states
Output voltage

CP-D 24/2.5
L, N

Frequency range AC

3

CP-D 24/1.3

Input circuit - supply circuit
Rated input voltage U in

min. 60 ms
2 A slow-acting /
250 V AC

3.15 A slow-acting
/ 250 V AC

DC ON: green LED V : output voltage applied
DC LOW: red LED V : output voltage too low

Output circuit
Rated output voltage

24 V DC

Tolerance of the output voltage

±1 %

Adjustment range of the output voltage

-

24-28 V DC

Rated output power

10 W

30 W

60 W

100 W

Rated output current I r

Ta  60 °C: 0.42 A

Ta  60 °C: 1.3 A

Ta  55 °C: 2.5 A

Ta  60 °C: 4.2 A

60 °C < Ta  70 °C:
2.5 %/°C

55 °C < Ta  70 °C:
2.5 %/°C

60 °C < Ta  70 °C:
2.5 %/°C

Derating of the output current
Maximum
­d eviation
with
Control time

+, -

60 °C < Ta  70 °C:
2.5 %/°C
load change statical max. 1 %

++, --

change of output voltage within the input voltage range max. 1 %
< 1 ms

Starting time after applying the supply voltage
Rise time
Residual ripple and switching peaks

at I r 1000 ms
at rated load typ. 1 ms
BW = 20 MHz 50 mV

Parallel connection

yes, using CP-D RU

Series connection

yes, to increase voltage

Resistance to reverse feed

35 V / 1 s

Output circuit - No-load, overload and short-circuit behaviour
Characteristic curve of output

U/I characteristic curve

Short-circuit protection

continuous short-circuit stability

Short-circuit behaviour

continuation with output power limiting

Current limiting at short circuit

typ. 0.78 A

Overload protection

output power limiting

Overvoltage protection

30-33 V DC

No-load protection

continuous no-load stability

Starting of capacitive loads

unlimited

General data
Efficiency

typ. 80 %

Duty time

100 %

Dimensions (W x H x D)
Weight

18 x 91 x 57.5 mm
(0.71 x 3.58 x
2.26 in)
0.066 kg (0.13 lb)

Material of housing

plastic

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

typ. 4.2 A

typ. 6.05 A

typ. 11.5 A

typ. 83 %

typ. 86 %

typ. 89 %

53 x 91 x 57.5 mm
(2.09 x 3.58 x
2.26 in)
0.196 kg (0.41 lb)

71 x 91 x 57.5 mm
(2.80 x 3.58 x
2.26 in)
0.252 kg (0.55 lb)

89.9 x 91 x 57,5 mm
(3.54 x 3.58 x
2.26 in)
0.386 kg / (0.72 lb)

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

II

3/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-D range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-D 24/0.42

CP-D 24/1.3

CP-D 24/2.5

CP-D 24/4.2

Electrical connection - Input circuit / Output circuit
Wire size
fine-strand with wire end ferrule 0.2-1.5 mm 2
0.2-2.5 mm 2 (24-14 AWG)
(24-16 AWG)
rigid 0.2-2.5 mm 2
0.2-2.5 mm 2 (24-12 AWG)
(26-12 AWG)
Stripping length
4-5 mm (0.16-0.2 in)
7 mm (0.28 in)
Tightening torque

0.6 Nm (5 lb.in)

3

0.7 Nm (6 lb.in)

Environmental data
Ambient temperature range

operation -40…+70 °C
rated load -40…+60 °C

-40…+55 °C

-40…+60 °C

4 kV AC

3 kV AC

storage -40…+85 °C
Damp heat (cyclic) (IEC/EN 60068-2-30)

4 x 24 cycles, 40 °C, 95 % RH

Vibration (sinusoidal) (IEC/EN 60068-2-6)

50 m/s 2, 10 Hz - 2 kHz

Shock (half-sine) (IEC/EN 60068-2-27)

40 m/s 2, 22 ms

Isolation data
Rated insulation voltage U i

input circuit / output circuit 3 kV AC

Pollution degree

2

Overvoltage category (UL/IEC/EN 60950-1)

ll

Standards
Product standard

EN 61204

Low Voltage Directive

2006/95/EC

EMC Direcitve

2004/108/EC

Electrical safety

UL 508, UL 60950-1, EN 60950-1

Protective low voltage

SELV (EN 60950-1)

Electromagnetic compatibility
Interference immunity to
electrostatic discharge
radiated, radio-frequency, electromagnetic field

EN 61000-6-2
IEC/EN 61000-4-2 Level 4
(4 kV / 8 kV)
IEC/EN 61000-4-3 Level 3 (10 V/m)

electrical fast transient/burst

IEC/EN 61000-4-4 Level 4 (4 kV)

surge

IEC/EN 61000-4-5 Level 3 (2 kV L-L)

conducted disturbances, induced by radiofrequency fields
Interference emission

IEC/EN 61000-4-6 Level 3 (10 V)

Level 4
(4 kV / 15 kV)

Level 4
(4 kV / 8 kV)

EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

„Approvals and marks“ on page 3/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/14

CP-D range
Technical diagrams

0.75

1

1.25
Iout [A]

0

Uout [V]
24
22
20
18
16
14
12
10
8
6
4
2
0

0.125

0.25

0.375

0.5

0.625

CP-D 24/0.42

0.75 0.875
Iout [A]

2CDC 272 021 F0207

Uout [V]
24
22
20
18
16
14
12
10
8
6
4
2
0
0

1

1.5

2

2.5

3

3.5

4
Iout [A]

2CDC 272 023 F0207

Uout [V]
24
22
20
18
16
14
12
10
8
6
4
2
0

0.5

1.5

2

2.5

1.5

2

4

5

1

0

1

2

3

-10

0

10

20

30

40

CP-D except CP-D 24/2.5

50

60

70

Ta [°C]

100
90
80
70
60
50
40
30
20
10
-10

0

10

20

30

40

50

CP-D 24/2.5

3/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

60

70

Ta [°C]

2CDC 272 018 F0207

Pout [%]

100
90
80
70
60
50
40
30
20
10

3.5

2.5

6

CP-D 24/4.2

Characteristic curve of temperature at rated output voltage
Pout [%]

3

4
Iout [A]

3

CP-D 24/1.3

Uout [V]

0

1

0.5

0

24
22
20
18
16
14
12
10
8
6
4
2
0

CP-D 24/2.5

0.5

CP-D 12/2.1

7

Iout [A]

8
Iout [A]

2CDC 272 022 F0207

0.5

2CDC 272 030 F0207

0.25

0

CP-D 12/0.83

2CDC 272 019 F0207

Uout [V]
12
11
10
9
8
7
6
5
4
3
2
1
0

2CDC 272 018 F0207

3

Uout [V]
12
11
10
9
8
7
6
5
4
3
2
1
0

2CDC 272 020 F0207

Characteristic curve of output at Ta = 25 °C

CP-D range
Dimensional drawings

Dimensional drawings

dimensions in mm

18,0 [0.71”]
53,0 [2.09”]

3

67,0 [2.64”]
44,5 [1.75”]

67,0 [2.64”]

CP-D 12/0.83, CP-D 24/0.42

2CDC 272 012 F0b07

32,1 [1.26”]

49,0 [1.93”]

57,5 [2.26”]

91,0 [3.58”]

2CDC 272 011 F0b07

57,5 [2.26”]

49,0 [1.93”]

32,1 [1.26”]

91,0 [3.58”]

44,5 [1.75”]

CP-D 12/2.1, CP-D 24/1.3

71,0 [2.80”]
89,9 [3.54”]

67,0 [2.64”]
67,0 [2.64”]

44,5 [1.75”]

CP-D 24/2.5

2CDC 272 014 F0b07

57,5 [2.26”]

49,0 [1.93”]

32,1 [1.26”]

91,0 [3.58”]

2CDC 272 013 F0b07

57,5 [2.26”]

49,0 [1.93”]

32,1 [1.26”]

91,0 [3.58”]

44,5 [1.75”]

CP-D 24/4.2

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/16

CP-E range
Product group picture

3

3/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-E range
Table of contents

CP-E range
Product group picture

3/17

Table of contents

3/18

Benefits and advantages

3/19

Ordering details

3/20

Technical data

3/21

Technical diagrams, Wiring instructions

3/29

Technical diagrams, Dimensional drawings

3/30

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/18

3

CP-E range
Benefits and advantages

Signalling output/contact 1
The CP-E range 24 V devices > 18 W offer an output/contact
for ­monitoring of the output v­ oltage and remote diagnosis.
Wide range input 2
Optimised for world-wide applications: The CP-E power
supplies can be supplied within a wide range of AC or DC
voltage.
Adjustable output voltage 3
The CP-E range types feature a continuously adjustable
output voltage. Thus, they can be optimally adapted to the
application, e.g. compensating the voltage drop caused by a
long line length.
Redundancy units 4
For decoupling of parallelized power supply units m 40 V.
Thus, true redundancy can be ­achieved.
Further information about redundancy unit on page 51.

4

1

2CDC 271 006 F0003

3
2CDC 276 008 F0006

2

Benefits

2CDC 276 009 F0006

1
2CDC 276 008 F0006

3

Characteristics
–– Output voltages 5 V, 12 V, 24 V, 48 V DC
–– Adjustable output voltages
–– Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / 3 A /
5 A / 10 A / 20 A
–– Power range 15 W, 18 W, 30 W, 60 W, 120 W, 240 W, 480 W
–– High efficiency of up to 90 %
–– Low power dissipation and low heating
–– Free convection cooling (no forced cooling with ventilators)
–– Ambient temperature range during operation -40...+70 °C
–– Open-circuit, overload and short-circuit stable
–– Integrated input fuse
–– U/I characteristic curve on devices > 18 W
(fold-forward behaviour at overload – no switch-off)
–– Redundancy units offering true redundancy
–– LED(s) for status indication
–– Signalling output/contact for output voltage OK
Transistor on 24 V devices > 18 W and < 120 W
–– Solid-state on 24 V devices M 120 W
–– Approvals / Marks
(depending on device, partly pending):
–– A, H, R , E / a, b

1 INPUT L, N, PE: terminals ‑ input
2 Circuit diagram
3 single/parallel: sliding switch - adjustment of single
or parallel operation

4 Indication of operational states

2

DC ON: green LED ‑ green LED ‑ output voltage OK
DC LOW: red LED ‑ output voltage too low

5 OUTPUT L+, L+, L‑, L-: terminals ‑ output
OUTPUT Adjust: potentiometer ‑ adjustment of output voltage

3
4
5

3/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-E range
Ordering details
Description
This range offers types with output voltages from 5 V DC to 48 V DC at output currents of
0.625 A to 20 A. The high thermal efficiency of up to 90 %, corresponding to very low power
and heat dissipation, allows operation without forced cooling. The functionality has been enhanced while the number of different types has been considerably reduced.
Of course all power supplies of the CP-E range are approved in accordance with all relevant
international standards.

3
Ordering details - CP-E < 100 W

2CDC 271 017 F0006

Input voltage range

CP-E 24/0.75

Rated output
voltage / current

Type

Order code

Price

90-264 V AC / 120-375 V DC

5 V DC / 3 A

CP-E 5/3.0

1SVR427033R3000

0.15
(0.33)

85-264 V AC / 90-375 V DC

12 V DC / 2.5 A

CP-E 12/2.5

1SVR427032R1000

0.29
(0.64)

90-132 V AC, 180-264 V AC /
210-375 V DC

12 V DC / 10 A

CP-E 12/10.0

1SVR427035R1000

1.00
(2.20)

90-264 V AC / 120-375 V DC

24 V DC / 0.75 A

CP-E 24/0.75

1SVR427030R0000

0.15
(0.33)

85-264 V AC / 90-375 V DC

24 V DC / 1.25 A

CP-E 24/1.25

1SVR427031R0000

0.29
(0.64)

85-264 V AC / 90-375 V DC

24 V DC / 2.5 A

CP-E 24/2.5

1SVR427032R0000

0.36
(0.79)

Rated output
voltage / current

Type

Order code

90-132 V AC, 180-264 V AC /
210-375 V DC

24 V DC / 5 A

CP-E 24/5.0

1SVR427034R0000

1.00
(2.20)

90-132 V AC, 180-264 V AC /
210-375 V DC

24 V DC / 10 A

CP-E 24/10.0

1SVR427035R0000

1.36
(3.01)

90-264 V AC / 120-375 V DC

24 V DC / 20 A

CP-E 24/20.0

1SVR427036R0000

1.90
(4.18)

85-264 V AC / 90-375 V DC

48 V DC / 0.625 A

CP-E 48/0.62

1SVR427030R2000

0.29
(0.64)

85-264 V AC / 90-375 V DC

48 V DC / 1.25 A

CP-E 48/1.25

1SVR427031R2000

0.36
(0.79)

90-132 V AC, 180-264 V AC /
210-375 V DC

48 V DC / 5 A

CP-E 48/5.0

1SVR427034R2000

1.36
(3.01)

90-264 V AC / 120-375 V DC

48 V DC / 10 A

CP-E 48/10.0

1SVR427035R2000

1.90
(4.19)

1 pce

Weight
(1 pce)
kg (lb)

Ordering details - CP-E M 120 W

2CDC 271 013 F0006

Input voltage range

2CDC 271 028 F0008

CP-E 12/2.5

CP-E 48/5.0

Price
1 pce

Weight
(1 pce)
kg (lb)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/20

CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-E 5/3.0

Input circuit
Rated input voltage U in

CP-E 12/10.0

L, N
100-240 V AC

Input voltage range

90-264 V AC /
120-375 V DC

Frequency range AC

3

CP-E 12/2.5

115 / 230 V AC
auto select
90-132 V AC,
180-264 V AC /
210-375 V DC

85-264 V AC /
90-375 V DC

47-63 Hz

Typical input current

at 115 V AC 335 mA

560 mA

2.2 A

at 230 V AC 210 mA

330 mA

0.83 A

35.9 W

143 W

at 115 V AC 10 A (max. 3 ms)

20 A (max. 3 ms)

24 A (max. 5 ms)

at 230 V AC 18 A (max. 3 ms)

40 A (max. 3 ms)

48 A (max. 5 ms)

at 115 V AC min. 20 ms

min. 20 ms

min. 25 ms

at 230 V AC min. 75 ms

min. 30 ms

min. 30 ms

Typical power consumption

19.8 W

Inrush current limiting
Discharge current

input / output 0.25 mA
input / PE 3.5 mA

Power failure buffering time
Internal input fuse

2 A slow-acting / 250 V AC

Power factor correction (PFC)

no

Indication of operational states
Output voltage

green LED OK: V :
output voltage OK
red LED LOW: V :
output voltage too low
L+,L-

Output circuit

3.15 A slow-acting /
250 V AC
yes, passive, 0.7

OUTPUT OK: V :
output voltage OK
-

OUTPUT OK: V :
output voltage OK
OUTPUT LOW: V :
output voltage too low
L+, L+, L-, L-

Rated output voltage

5 V DC

Tolerance of the output voltage

0...+1 %

Adjustment range of the output voltage

4.5-5.75 V DC

12-14 V DC

11.4-14.5 V DC

Rated output power

15 W

30 W

120 W

2.5 A

10 A

Rated output current I r

Ta m 60 °C 3.0 A
60 °C < Ta m 70 °C 2.5 %/°C
load change statical ±2 %

Derating of the output current
Maximum deviation with

Control time

±0.5 %

with 3500 µF -

max. 2 s

-

with 7000 µF max. 1.5 s

-

max. 1.5 s

with 3500 µF -

max. 500 ms

-

with 7000 µF max. 500 ms

-

max. 500 ms

change of output voltage within the ±1 %
input voltage range
< 2 ms

±0.5 %

at I r max. 1 s

at rated load max. 150 ms

Fall time
Residual ripple and switching peaks

2.5 %/°C
±1 % (single mode)
±5 % (parallel mode)
±0.5 %

Starting time after applying the supply voltage

Rise time

12 V DC

max. 150 ms
BW = 20 MHz 50 mV

Parallel connection

yes, to enable redundancy

Series connection

yes, to increase voltage

Resistance to reverse feed

1 s - max. 7.5 V DC

1 s - max.18 V DC

Characteristic curve of output

Hiccup-mode

U/I characteristic curve

Short-circuit protection

continuous short-circuit proof

Short-circuit behaviour

Hiccup-mode

Overload protection

output power limiting

No-load protection

continuous no-load stability

Starting of capacitive loads

7000 µF

configurable, to
­increase power,up to 3
devices,
min. 0.1 I r - max. 0.9 I r
yes, to increase
voltage, max. 2
devices
max. 18 V DC

Output circuit - No-load, overload and short-circuit behaviour

3/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

continuation with output power limiting

3500 µF

7000 µF

CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-E 5/3.0

CP-E 12/2.5

CP-E 12/10.0

General data
Power dissipation

typ. 5 W

typ. 5.6 W

typ. 24 W

Efficiency

typ. 75 %

typ. 84 %

typ. 84 %

Duty time

100 %

Dimensions (W x H x D)
Weight

22.5 x 90 x 114 mm
(0.89 x 3.54 x 4.49 in)
0.144 kg (0.317 lb)

40.5 x 90 x 114 mm
(1.59 x 3.54 x 4.49 in)
0.287 kg (0.633 lb)

63.2 x 123.6 x 123.6 mm
(2.49 x 4.87 x 4.87 in)
0.888 kg (1.958 lb)

Material of housing

Plastic

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

Metal

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

I

Electrical connection - input circuit / output circuit
Wire size
fine-strand with wire end ferrule 0.2-2.5 mm 2 (24-14 AWG)
fine-strand without wire end ferrule

0.2-4 mm² (24-11 AWG)
0.2-6 mm² (24-10 AWG)

rigid
Stripping length
Tightening torque
Environmental data
Ambient temperature range

6 mm (0.24 in)

8 mm (0.31 in)

input / output 0.6 Nm (5 lb.in)

1.0 Nm (9 lb.in) /
0.62 Nm (5.5 lb.in)

operation -20…+70 °C

-40…+70 °C

-35…+70 °C

rated load -20...+60 °C

-40...+60 °C

-35...+60 °C

storage -20…+85 °C

-40…+85 °C

-40…+85 °C

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 RH, % without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis

Shock (half-sine) (IEC/EN 60068-2-27)

15 G, 11 ms, 3 axes, 6 faces, 3 times for each face

Isolation data
Rated insulation voltage U i

input circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC

Pollution degree

2

Overvoltage category (UL/IEC/EN 60950-1)

II

Standards
Product standard

EN 61204-3

Low Voltage Directive

2006/95/EC

EMC directive

2004/108/EC

RoHS directive

2011/65/EC

Electrical safety

EN 60950-1,
UL 60950-1, UL 508
SELV (EN 60950)

Protective low voltage
Electromagnetic compatibility
Interference immunity to

EN 60950-1, UL 60950-1, UL 508,
EN 61558-1, EN 61558-2-17; EN 60204-1

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)

radiated, radio-frequency, electromagnetic
field
electrical fast transient/burst

IEC/EN 61000-4-3 Level 3 (10 V/m)
IEC/EN 61000-4-4 Level 4 (4 kV / 2,5 kHz) Level 4 (4 kV / 5 kHz)

surge

IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)

conducted disturbances, induced by radiofrequency fields
power frequency magnetic fields

IEC/EN 61000-4-6 Level 3 (10 V)
IEC/EN 61000-4-8 Level 4 (30 A/m)

voltage dips, short interruptions and voltage
variations
Interference emission
high-frequency radiated

IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms
interruptions: >95 % 5000 ms
IEC/EN 61000-6-3
IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

limits for harmonic current emissions

IEC/EN 61000-3-2 Class D

Class A

Class D

„Approvals and marks“ on page 3/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/22

3

CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-E 24/0.75

Input circuit
Rated input voltage U in

CP-E 24/2.5

L, N
100-240 V AC

Input voltage range

90-264 V AC /
120-375 V DC

Frequency range AC

85-264 V AC /
90-375 V DC

47-63 Hz

Typical input current

3

CP-E 24/1.25

at 115 V AC 335 mA

560 mA

1060 mA

at 230 V AC 210 mA

330 mA

590 mA

36.7 W

69.2 W

at 115 V AC 10 A (max. 3 ms)

20 A (max. 3 ms)

20 A (max. 3 ms)

at 230 V AC 18 A (max. 3 ms)

40 A (max. 3 ms)

40 A (max. 3 ms)

Typical power consumption

22.8 W

Inrush current limiting
Discharge current

input / output 0.25 mA
input / PE 3.5 mA

Power failure buffering time

at 115 V AC min. 20 ms

min. 20 ms

at 230 V AC min. 75 ms

min. 30 ms

Internal input fuse

2 A slow-acting / 250 V AC

Power factor correction (PFC)

no

Indication of operational states
Output voltage

green LED OK: V :
output voltage OK
red LED LOW: V :
output voltage too low

OUTPUT OK: V : output voltage OK
-

L+,L-

-

Output circuit
Rated output voltage

24 V DC

Tolerance of the output voltage

0 ... +1 %

Adjustment range of the output voltage

21.6-28.8 V DC

24-28 V DC

Rated output power

18 W

30 W

60 W

1.25 A

2.5 A

Rated output current I r

Ta m 60 °C 0.75 A
60 °C < Ta m 70 °C 2.5 %/°C
DC OK -

Derating of the output current
Signalling output for output voltage OK
Maximum deviation with

Control time

load change statical ±2 %
change of output voltage within the ±1 %
input voltage range
< 2 ms

Starting time after applying the supply voltage

Rise time

transistor
±0.5 %
±0.5 %

at I r max. 1 s
with 3500 µF -

max. 2 s

-

with 7000 µF max. 1.5 s

-

max. 1.5 s

with 3500 µF -

max. 500 ms

-

with 7000 µF max. 500 ms

-

max. 500 ms

at rated load max. 150 ms

Fall time
Residual ripple and switching peaks

L+, L+, L-, L-

max. 150 ms
BW = 20 MHz 50 mV

Parallel connection
Series connection
Resistance to reverse feed
Output circuit - No-load, overload and short-circuit behaviour
Characteristic curve of output

yes, to enable redundancy
yes, to increase voltage
1 s - max. 35 V DC

Short-circuit protection

continuous short-circuit proof

Short-circuit behaviour

Hiccup-mode

Overload protection

output power limiting

No-load protection

continuous no-load stability

Starting of capacitive loads

7000 µF

Hiccup-mode

3/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

U/I characteristic curve
continuation with output power limiting

3500 µF

7000 µF

CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type
General data
Power dissipation

CP-E 24/0.75
typ. 4.45 W

typ. 5.5 W

typ. 8.8 W

Efficiency

typ. 77 %

typ. 86 %

typ. 89 %

Duty time

100 %

Dimensions (W x H x D)

22.5 x 90 x 114 mm
(0.89 x 3.54 x 4.49 in)

40.5 x 90 x 114 mm
(1.59 x 3.54 x 4.49 in)

Weight

0.143 kg (0.315 lb)

0.270 kg (0.60 lb)

Material of housing

Plastic

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

CP-E 24/1.25

CP-E 24/2.5

0.331 kg (0.73 lb)

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

I

Electrical connection - input circuit / output circuit
Wire size
fine-strand with wire end ferrule 0.2-2.5 mm 2 (24-14 AWG)
fine-strand without wire end ferrule
rigid
Stripping length

6 mm (0.24 in)

Tightening torque

input / output 0.6 Nm (5 lb.in)

Environmental data
Ambient temperature range

operation -20…+70 °C

-40…+70 °C

rated load -20…+60 °C

-40…+60 °C

storage -20…+85 °C

-40…+85 °C

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 % RH, without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis

Shock (half-sine) (IEC/EN 60068-2-27)

15 G, 11 ms, 3 axes, 6 faces, 3 times for each face

Isolation data
Rated insulation voltage U i

input circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC

Pollution degree

2

Overvoltage category (UL/IEC/EN 60950-1)

II

Standards
Product standard

EN 61204-3

Low Voltage Directive

2006/95/EC

EMC directive

2004/108/EC

RoHS directive

2011/65/EC

Electrical safety

EN 50178, EN 60950-1,
UL 60950-1, UL 508

Protective low voltage

SELV (EN 60950)

Electromagnetic compatibility
Interference immunity to
electrostatic discharge

EN 60950-1, UL 60950-1, UL 508, EN 61558-1,
EN 61558-2-17; EN 60204-1

IEC/EN 61000-6-2
IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 Level 3 (10 V/m)

electrical fast transient/burst

IEC/EN 61000-4-4 Level 4 (4 kV / 2.5 kHz) Level 4 (4 kV / 5 kHz)

surge

IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)

conducted disturbances, induced by radiofrequency fields

IEC/EN 61000-4-6 Level 3 (10 V)

power frequency magnetic fields
voltage dips, short interruptions and voltage
variations
Interference emission

IEC/EN 61000-4-8 Level 4 (30 A/m)
IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms, interruptions: >95 % 5000 ms
IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

limits for harmonic current emissions

IEC/EN 61000-3-2 Class D

Class A

„Approvals and marks“ on page 3/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/24

3

CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-E 24/5.0

Input circuit
Rated input voltage U in

CP-E 24/20.0

L, N

Input voltage range
Frequency range AC
Typical input current

3

CP-E 24/10.0

115-230 V AC

90-132 V AC,
180-264 V AC /
210-375 V DC
47-63 Hz

90-132 V AC,
180-264 V AC /
210-375 V DC

90-264 V AC,
120-375 V DC

at 115 V AC 2.2 A

4.0 A

4.9 A

at 230 V AC 0.83 A

1.55 A

2.5 A

140 W

270 W

539 W

at 115 V AC 24 A (max. 5 ms)

30 A (max. 5 ms)

25 A (max. 5 ms)

at 230 V AC 48 A (max. 5 ms)

60 A (max. 5 ms)

50 A (max. 5 ms)

6.3 A slow-acting /
250 V AC

10 A slow-acting /
250 V AC

Typical power consumption
Inrush current limiting
Discharge current

115 / 230 V AC auto select

input / output 0.25 mA
input / PE 3.5 mA

Power failure buffering time

at 115 V AC min. 25 ms
at 230 V AC min. 30 ms

Internal input fuse

3.15 A slow-acting /
250 V AC

Power factor correction (PFC)

yes, passive, 0.7

Indication of operational states
Output voltage

yes, active
115 V AC: 0.99
230 V AC: 0.97

green LED OUTPUT OK: V : output voltage OK
red LED OUTPUT LOW: V : output voltage too low

Output circuit
Rated output voltage

24 V DC

L+, L+, L-, L-

Tolerance of the output voltage

0...+1 %

Adjustment range of the output voltage

22.5-28.5 V DC

Rated output power

120 W

Rated output current I r

Ta m 60 °C 5 A
Ta m 55 °C -

Derating of the output current

60 °C < Ta m 70 °C 2.5 %/°C
55 °C < Ta m 70 °C -

Signalling contact for output voltage OK

240 W

480 W

10 A

-

-

20 A
-

-

2.5 %/°C

13-14 solid-state (max. 60 V DC, 0.3 A)

Minimum fuse rating to achieve short-circuit protection

13-14 M 60 V DC, m 0.3 A fast-acting
load change statical ±1 % (single mode), ±5 % (parallel mode)

Maximum deviation with

Control time

change of output voltage within ±0.5 %
the input voltage range
< 2 ms

Starting time after applying the supply voltage

Rise time

at I r max. 1 s
with 3500 µF max. 1.5 s

-

with 7000 µF -

max. 1.5 s

at rated load max. 150 ms
with 3500 µF max. 500 ms

-

with 7000 µF -

max. 500 ms

Fall time
Residual ripple and switching peaks

-

-

max. 150 ms
BW = 20 MHz 50 mV

100 mV

Parallel connection

configurable, to i­ncrease power, up to 3 devices, min. 0.1 Ir - max. 0.9 Ir

Series connection

yes, to increase voltage, max. 2 devices

Resistance to reverse feed

max. 35 V DC

Output circuit - No-load, overload and short-circuit behaviour
Characteristic curve of output

U/I characteristic curve

Short-circuit protection

continuous short-circuit proof

Short-circuit behaviour

continuation with output power limiting

Overload protection

output power limiting

No-load protection

continuous no-load stability

Starting of capacitive loads

3500 µF

3/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

7000 µF

CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-E 24/5.0

CP-E 24/10.0

CP-E 24/20.0

General data
Power dissipation

typ. 20 W

typ. 35 W

typ. 63 W

Efficiency

typ. 86 %

typ. 89 %

typ. 89 %

Duty time

100 %

Dimensions (W x H x D)

63.2 x 123.6 x 123.6 mm
(2.49 x 4.87 x 4.87 in)

83 x 123.6 x 123.6 mm
(3.27 x 4.87 x 4.87 in)

175 x 123.6 x 123.6 mm
(6.89 x 4.87 x 4.87 in)

Weight

0.882 kg (1.945 lb)

1.334 kg (2.941 lb)

1.850 kg (4.079 lb)

Material of housing

Metal

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

I

Electrical connection - input circuit / output circuit
Wire size
fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG)
fine-strand without wire end 0.2-6 mm² (24-10 AWG)
ferrule
rigid
Stripping length
Tightening torque
Environmental data
Ambient temperature range

8 mm (0.31 in)
input / output 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in)
operation -35…+70 °C

-40…+70 °C

rated load -35…+60 °C

-40…+60 °C

storage -40…+85 °C

-40…+85 °C

-40…+55 °C

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 %RH, without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis

Shock (half-sine) (IEC/EN 60068-2-27)

15 G, 11 ms, 3 axes, 6 faces, 3 times for each face

Isolation data
Rated insulation voltage U i

input circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC
signalling contact / PE 0.5 kV DC

Pollution degree

2

Overvoltage category (UL/IEC/EN 60950-1)

II

Standards
Product standard

EN 61204-3

Low Voltage Directive

2006/95/EC

EMC directive

2004/108/EC

RoHS directive

2011/65/EC

Electrical safety

EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN
60204-1
SELV (EN 60950)

Protective low voltage
Electromagnetic compatibility
Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)

radiated, radio-frequency, electromagnetic
field
electrical fast transient/burst

IEC/EN 61000-4-3 Level 3 (10 V/m)
IEC/EN 61000-4-4 Level 4 (4 kV / 5 kHz)

surge

IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)

conducted disturbances, induced by radiofrequency fields
power frequency magnetic fields

IEC/EN 61000-4-6 Level 3 (10 V)

voltage dips, short interruptions and voltage
variations
Interference emission

IEC/EN 61000-4-8 Level 4 (30 A/m)
IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms
interruptions: >95 % 5000 ms
IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

limits for harmonic current emissions

Level 4 (4 kV / 2.5 kHz)

Class D

„Approvals and marks“ on page 3/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/26

3

CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-E 48/0.62

Input circuit
Rated input voltage U in

3

Typical power consumption
Inrush current limiting
Discharge current
Power failure buffering time

85-264 V AC /
90-375 V DC
47-63 Hz
at 115 V AC 560 mA
at 230 V AC 330 mA
35.7 W

4.0 A

4.9 A

1.55 A

2.5 A

69.0 W

267 W

min. 25 ms

10 A slowacting /
250 V AC
yes, active
yes, passive, 0.7 115 V AC: 0.99
230 V AC: 0.97

green LED OUTPUT OK: V : output voltage OK
red LED
OUTPUT LOW: V :
output voltage too low
L+, L+, L-, L48 V DC

Tolerance of the output voltage

0...+1 %

Adjustment range of the output voltage

48-55 V DC

Rated output power

30 W

Rated output current I r

Ta m 60 °C 0.625 A
Ta m 55 °C 60 °C < Ta m 70 °C 2.5 %/°C
55 °C < Ta m 70 °C DC OK load change statical

47-56 V DC
60 W

240 W

480 W

1.25 A

5A

-

-

-

10 A

-

-

-

±1 % (single mode)
±5 % (parallel mode)

-

±0.5 %

change of output voltage within
±0.5 %
the input voltage range
Control time
< 2 ms
Starting time after applying the supply voltage
at I r max. 1 s
with 3500 µF max. 2 s
with 7000 µF -

Fall time
Residual ripple and switching peaks

min. 25 ms

6.3 A slowacting /
250 V AC

no

Output circuit
Rated output voltage

Rise time

90-264 V AC,
120-375 V DC

590 mA

2 A slow-acting /
250 V AC

Indication of operational states
Output voltage

Maximum deviation with

115-230 V AC

1060 mA

input / PE 3.5 mA
at 115 V AC min. 20 ms
at 230 V AC min. 30 ms

Power factor correction (PFC)

Signalling output for output voltage OK

CP-E 48/10.0

528 W
at 115 V AC 20 A (max. 3 ms) 20 A (max. 3 ms) 30 A (max. 5 ms) 25 A (max. 5 ms)
at 230 V AC 40 A (max. 3 ms) 40 A (max. 3 ms) 60 A (max. 5 ms) 50 A (max. 5 ms)
input / output 0.25 mA

Internal input fuse

Derating of the output current

CP-E 48/5.0
L, N
115 / 230 V AC
auto select
90-132 V AC,
180-264 V AC /
210-375 V DC

100-240 V AC

Input voltage range
Frequency range AC
Typical input current

CP-E 48/1.25

at rated load max. 150 ms
with 3500 µF max. 500 ms
with 7000 µF -

±0.5 %

-

-

max. 1.5 s

max. 1.5 s

-

-

max. 500 ms

max. 500 ms

max. 150 ms
BW = 20 MHz 50 mV
yes, to enable redundancy

-

yes, to increase voltage

configurable, to ­increase power,
up to 3 devices,
min. 0.1 I r - max. 0.9 I r
yes, to increase voltage,
max. 2 devices

Resistance to reverse feed

1 s - max. 63 V DC

Output circuit - No-load, overload and short-circuit behaviour
Characteristic curve of output

U/I characteristic curve

Short-circuit protection

continuous short-circuit proof

Short-circuit behaviour

continuation with output power limiting

Overload protection

output power limiting

No-load protection

continuous no-load stability

Starting of capacitive loads

3500 µF

3/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

-

100 mV

Parallel connection

Series connection

2.5 %/°C

7000 µF

unlimited

7000 µF

CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type

CP-E 48/0.62

General data
Power dissipation
Efficiency
Duty time
Dimensions (W x H x D)

typ. 4.9 W
typ. 86 %
100 %

CP-E 48/1.25
typ. 7.8 W
typ. 89 %

CP-E 48/5.0
typ. 32 W
typ. 90 %

CP-E 48/10.0
typ. 60 W

Weight

83 x 123.6 x
123.6 mm
(3.27 x 4.87 x
4.87 in)
0.264 kg (0.582 lb) 0.316 kg (0.697 lb) 1.322 kg (2.915 lb)

Material of housing

Plastic

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

40.5 x 90 x 114 mm
(1.59 x 3.54 x 4.49 in)

Mounting position

175 x 123.6 x
123.6 mm
(6.89 x 4.87 x
4.87 in)
1.839 kg (4.054 lb)

Metal

horizontal
horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)
housing / terminals IP/20 / IP20

Minimum distance to other units
Degree of protection
Protection class

I

Electrical connection - input circuit / output circuit
Wire size
fine-strand with wire end ferrule

0.2-4 mm² (24-11 AWG)

fine-strand without wire end ferrule 0.2-2.5 mm² (24-14 AWG)
rigid
Stripping length
Tightening torque
Environmental data
Ambient temperature range

6 mm (0.24 in)
input / output 0.6 Nm (5 lb.in)

0.2-6 mm² (24-10 AWG)
8 mm (0.31 in)
1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in)

operation -40…+70 °C
rated load -40…+60 °C
storage -40…+85 °C

-40…+55 °C

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 % RH, without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis

Shock (half-sine) (IEC/EN 60068-2-27)

15 G, 11 ms, 3 axes, 6 faces, 3 times for each face

Isolation data
Rated insulation voltage U i

input circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC

Pollution degree

2

Overvoltage category (UL/IEC/EN 60950-1)

II

Standards
Product standard

EN 61204-3

Low Voltage Directive

2006/95/EC

EMC directive

2004/108/EC

RoHS directive

2011/65/EC

Electrical safety

EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1

Protective low voltage

SELV (EN 60950)

Electromagnetic compatibility
Interference immunity to
electrostatic discharge
radiated, radio-frequency, electromagnetic
field
electrical fast transient/burst
surge
conducted disturbances, induced by radiofrequency fields
power frequency magnetic fields
voltage dips, short interruptions and voltage
variations
Interference emission
high-frequency radiated
high-frequency conducted
limits for harmonic current emissions

IEC/EN 61000-6-2
IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)
IEC/EN 61000-4-3
Level 3 (10 V/m)
IEC/EN 61000-4-4 Level 4 (4 kV / 5 kHz)
Level 4 (4 kV / 2.5 kHz)
IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)
IEC/EN 61000-4-6
Level 3 (10 V/m)
IEC/EN 61000-4-8 Level 4 (30 A/m)
IEC/EN 61000-4-11

dip: >95 % 10 ms / >30 % 500 ms, interruptions: >95 % 5000 ms

IEC/EN 61000-6-3
IEC/CISPR 22, EN 55022 Class B
IEC/CISPR 22, EN 55022 Class B
Class A

Class D

„Approvals and marks“ on page 3/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/28

3

CP-E range
Technical diagrams, Wiring instructions
Output curve at Ta = 25 °C
Uout [V]

14

13

12

11

10

9

8

7

6

5

3.2

3.3

3.4

3.5

3.6 3.7
Iout [A]

2
2

CP-E 12/2.5

4

6

8

10

12

14

16

Iout [A]

CP-E 12/10.0

Uout [V]

CP-E 24/1.25

Uout [V]

Uout [V]

28

28

24

24

20

20

16

16

12

12

8

8

4

2CDC 272 007 F0b07

2.75 2.85 2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65
Iout [A]

1.25 1.35 1.45 1.55 1.65 1.75 1.85 1.95 2.05 2.15
Iout [A]

1

2

3

4

5

6

7

8

Iout [A]

Iout [A]

1.33 1.41 1.49 1.57 1.65 1.73 1.81 1.89 1.97 2.05
Iout [A]

4
2

4

CP-E 24/10.0

Uout [V]

Uout [V]

Uout [V]

28

70

70

24

60

60

20

50

50

16

40

40

12

30

30

8

20

20

10

10

8

12

16

20

24

28

32

Iout [A]

0.665 0.705 0.745 0.785 0.825 0.865 0.905 0.945 0.985 1.025
Iout [A]

CP-E 24/20.0

CP-E 48/0.62

Uout [V]

Uout [V]

56

56

48

48

40

40

32

32

24

24

16

16

8
1

2

3

4

5

6

7

8

Iout [A]

CP-E 48/1.25

8
2

CP-E 48/5.0

4

6

8

10

12

14

CP-E 48/10.0

Wiring instructions
5 V Signal

DC OK

DC OK

L-

L-

2.2 k
0.5 W
5.1 V
0.3 W

2CDC 272 017 F0207

Relay

RL > 700 

CP-E 24/1.25, CP-E 24/2.5

3/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

16

Iout [A]

2CDC 272 010 F0b08

4

2CDC 272 009 F0b07

CP-E 24/5.0

2CDC 272 008 F0b08

CP-E 24/2.5

4

2CDC 272 006 F0b07

3.1

2CDC 272 007 F0b08

3.0

2CDC 272 010 F0b07

2.9

2CDC 272 006 F0b08

2.8

2CDC 272 008 F0b07

1

2CDC 272 005 F0b08

4

3

2CDC 272 009 F0b08

3

Uout [V]

Uout [V]

15

6

8

10

12

14

16

CP-E range
Technical diagrams, Dimensional drawings
Temperature behaviour at Ta = 25 °C
Pout [%]

-35

60

70

2CDC 272 015 F0211

100
90
80
70
60
50
40
30
20
10
Ta [°C]

CP-E 12/10.0, CP-E 24/5.0

100
90
80
70
60
50
40
30
20
10

3

-40

70

55

Ta [°C]

2CDC 272 018 F0211

Pout [%]

CP-E 24/20.0, CP-E 48/10.0

Pout [%]

-20

60

70

2CDC 272 016 F0211

100
90
80
70
60
50
40
30
20
10
Ta [°C]

CP-E 5/3.0, CP-E 24/0.75

60

70

Ta [°C]

dimensions in mm
22.5

4.49“

0.89“

40.5 1.59”

63,2 [2.49“]

123,6 [4.87“]

83,0 [3.27“]

175,0 [6.89“]

CP-E 12/10.0,
CP-E 24/5.0

123,6 [4.87“]

123,6 [4.87“]

CP-E 24/10.0,
CP-E 48/5.0

2CDC 272 013 F008

12/2.5,
24/1.25,
24/2.5,
48/0.62,
48/1.25

123,6 [4.87“]

2CDC 272 021 F0011

CP-E
CP-E
CP-E
CP-E
CP-E

2CDC 272 013 F0b08

CP-E 5/3.0,
CP-E 24/0.75

3.54”

116,6 [4.59“]

90 3.54“

114

-40

CP-E 12/2.5, CP-E 24/1.25, CP-E 48/0.62,
CP-E 24/2.5, CP-E 48/1.25, CP-E 24/10.0, CP-E 48/5.0

90

Dimensional drawings

100
90
80
70
60
50
40
30
20
10

2CDC 272 017 F0211

Pout [%]

CP-E 24/20.0,
CP-E 48/10.0

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/30

CP-T range
Product group picture

3

3/31 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-T range
Table of contents

CP-T range
Product group picture

3/31

Table of contents

3/32

Benefits and advantages

3/33

Ordering details

3/34

Technical data

3/35

Technical diagrams, Dimensional drawings

3/39

Technical diagrams

3/40

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/32

3

CP-T range
Benefits and advantages

1

Benefits
Signalling output 1
The devices of the CP-T series offer a solid state output for
function monitoring and remote diagnostics.
Wide input range
Wide range input optimized for world-wide applications:
The CP-T power supplies can be used in 340 - 575 V AC or
480 - 820 V DC supply systems.
Adjustable output voltage 2
The CP-T range feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application,
e.g. compensating the voltage drop caused by a long line
length.

480 W variants: -30...+70°C

2

2CDC 271 043 S0009

1)

2CDC 271 043 S0009

3

Characteristics
–– Rated output voltages 24 V, 48 V DC
–– Output voltage adjustable via front-face rotary potentiometer “OUTPUT Adjust”
–– Rated output currents 5 A, 10 A, 20 A, 40 A
–– Rated output powers 120 W, 240 W, 480 W, 960 W
–– Three-phase operation (see derating note)
–– Two-phase operation (25 % derating possible, see derating note)
–– Supply range 3 x 400–500 V AC (3 x 340–575 V AC,
480–820 V DC)
–– Typical efficiency of 93 %
–– Low power dissipation and low heating
–– Free convection cooling (no forced cooling with ventilators)
–– Ambient temperature range during operation -40...+70 °C 1)
–– Open-circuit, overload and short-circuit stable
–– Integrated input fuse
–– Redundancy unit CP-A RU offering true redundancy, available as accessory
–– LEDs for status indication
–– Signalling contact "13-14" (solid state) for output voltage
OK
–– Approvals / marks (depending on device, partly pending):
–– A, H, R , E / a , b

1 Circuit diagram
2 Indication of operational states
DC ON: green LED ‑ green LED ‑ output voltage OK
DC LOW: red LED ‑ output voltage too low

3 single/parallel: sliding switch - adjustment
of single or parallel operation

1

4 Configuration of single or parallel operation
5 Signalling contact
OUTPUT 13-14: terminals - signalling contact
A solid-state output indicates the error-free operation of the
output voltage.
OUTPUT L+, L+, L-, L-: terminals - output

2
3
4
5

7

3/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

7

INPUT L1, L2, L3, PE: terminals - input

CP-T range
Ordering details
Description

2CDC 271 043 S0009

The CP-T range of three-phase power supply units is the youngest member of ABB‘s power
supply family. In terms of design and functionality, the new range perfectly supplements the existing products and extends the range appropriately. The devices can be supplied with a threephase voltage as well as with two-phase mains. Here, ABB offers power supply units with 24 V
DC and 48 V DC outputs with 5 A, 10 A, 20 A and 40 A and efficiency of up to 92 %. As in the
case of all products, they are designed for an ambient temperature of up to 70 °C. All products can be supplied within an AC supply voltage range between 340 to 575 V AC and a DC
supply voltage range between 480 to 820 V DC.

Ordering details
Input voltage range

Rated
output voltage /
current

Type

340-575 V AC / 480-820 V DC

24 V DC / 5 A

CP-T 24/5.0

1SVR427054R0000

0.80
(1.77)

340-575 V AC / 480-820 V DC

24 V DC / 10 A

CP-T 24/10.0

1SVR427055R0000

1.05
(2.31)

340-575 V AC / 480-820 V DC

24 V DC / 20 A

CP-T 24/20.0

1SVR427056R0000

1.75
(3.86)

340-575 V AC / 480-820 V DC

24 V DC / 40 A

CP-T 24/40.0

1SVR427057R0000

3.20
(7.05)

340-575 V AC / 480-820 V DC

48 V DC / 5 A

CP-T 48/5.0

1SVR427054R2000

1.05
(2.31)

340-575 V AC / 480-820 V DC

48 V DC / 10 A

CP-T 48/10.0

1SVR427055R2000

1.75
(3.86)

340-575 V AC / 480-820 V DC

48 V DC / 20 A

CP-T 48/20.0

1SVR427056R2000

3.40
(7.50)

2CDC 271 045 S0009

CP-T 24/5.0

Price
1 pce

Weight
(1 pce)
kg (lb)

2CDC 271 047 S0009

CP-T 24/10.0, CP-T 48/5.0

Order code

CP-T 24/20.0, CP-T 48/10.0

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/34

3

CP-T range
Technical data
Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated
Type

CP-T 24/5.0

Input circuit
Rated input voltage U in

3 x 400-500 V AC

Input voltage range

340-575 V AC

CP-T 24/10.0

CP-T 24/20.0

CP-T 24/40.0

L1, L2, L3

480-820 V DC

3

Frequency range AC

47-63 Hz

Typical input current

0.36 A

0.65 A

1.1 A

1.72 A

Typical power consumption

135 W

270 W

538 W

1058 W

Inrush current limiting

10 A

20 A

Power failure buffering time

min. 20 ms

Internal input fuse

30 A
min. 15 ms

per phase 2 A / 600 V AC

Recommended backup fuse

T 3.15 A / 500 V AC

T 5 A / 500 V AC

3 pole miniature circuit breaker ABB Type S203

Power factor correction (PFC)

Yes, passive

Discharge current

towards PE < 3.5 mA
input / output < 0.25 mA

Indication of operational states
Output voltage

OUTPUT OK: green LED output voltage OK
OUTPUT LOW: red LED output voltage too low

Output circuit
Rated output voltage

24 V DC

L+, L+, L-, L-

Tolerance of the output voltage

0...+1 %

Adjustment range of the output voltage

22.5-28.5 V DC

Rated output power

120 W
Ta ≤ 60 °C 5 A
60 °C < Ta ≤ 70 °C 2.5 %/°C

Rated output current I r
Derating of the output current
Signalling contact
for output voltage OK

240 W

480 W

960 W

10 A

20 A

40 A
3.5 %/°C

13-14 solid state (max. 60 V DC, 0.3 A)
Threshold 17.6-19.4 V
Insulation voltage 500 V DC

Mininum fuse rating to achieve short-circuit protection
Maximum deviation with

13-14 M 60 V DC, m 0.3 A fast-acting
load change statical ±1 %
±1 % (single mode)
-

Control time
Starting time after applying
the supply voltage
Rise time

±5 % (parallel mode)

change of output voltage ± 0.5 %
within the input voltage range
at nominal load < 2 ms
at I r max. 1 s
with 3500 µF max. 1.5 s
at nominal load max. 150 ms
with 3500 µF max. 500 ms

Fall time
Residual ripple and switching peaks

max. 150 ms
BW = 20 MHz 100 mV

80 mV

Parallel connection

not supported

configurable, to increase power, up to increase power,
to 2 devices, min. 0.1 I r - max 0.9 I r) up to 2 devices,
min. 0.1 I r - max.
0.9 I r use active
current balancing

Series connection

not supported

yes, to increase voltage, max. 2 devices

Resistance to reverse feed

approx. 35 V

Output circuit - No-load, overload and short-circuit behaviour
Characteristic curve of output

combined U/I characteristic curve
and hiccup mode

U/I- or Hiccuphiccup / fold
mode adjustable back behavior

Short-circuit protection

continuous short-circuit proof

Short-circuit behaviour

current limiting

Overload protection

hiccup mode

No-load protection

continuous no-load stability

Overtemperature protection

yes, automatic recovery after temperature went down

Starting of capacitive loads

3500 µF

3/35 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

7000 µF

7000 µF

7000 µF

CP-T range
Technical data
Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated
Type

CP-T 24/5.0

General data
Efficiency
Duty time
Dimensions (W x H x D)

typ. 89 %
100%
74.3 x 124 x
118.8 mm
(2.92 x 4.88 x
4.68 in)

Weight
Material of housing
Mounting
Mounting position
Minimum distance to other units
horizontal / vertical
Degree of protection
housing / terminals
Protection class
Electrical connection - input circuit / output circuit / signalling circuit
Wire size
fine-strand with wire end ferrule

CP-T 24/10.0

CP-T 24/20.0

typ. 90 %
89 x 124 x 118.8
mm
(3.5 x 4.88 x
4.68 in)

CP-T 24/40.0
typ. 92 %

150 x 124 x
118.8 mm
(5.91 x 4.88 x
4.68 in)

275.8 x 124 x
118.8 mm
(10.86 x 4.88 x
4.68 in)

0.78 kg (1.72 lb) 1.045 kg (2.30 lb) 1.657 kg (3.653 lb) 3.275 kg (7.220 lb)
Metal
DIN rail (IEC EN 60715), snap-on mounting without any tool
horizontal
25 mm / 25 mm (0.98 in / 0.98 in)
IP20 / IP20
I
0.2-4 mm² (24-11 AWG)

fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG)
rigid 0.2-6 mm² (24-10 AWG)
Stripping length
Tightening torque
Environmental data
Ambient temperature range

8 mm (0.31 in)
input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in)

1 Nm (9 lb.in) /
1.8 Nm (15.6 lb.in)

operation -40...+70 °C

-30…+70 °C

-40...+70 °C

rated load -40...+60 °C

-30…+60 °C

-40...+60 °C

storage -40…+85 °C
Damp heat (cyclic) (IEC/EN 60068-2-30)

95 % without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

2 g, 10-500 Hz, 2G, each along X, Y, Z axes 60 min / cycle

Shock (half-sine) (IEC/EN 60068-2-27)

15 g, 11 ms, 3 axes, 6 faces, 3 times for each face

Isolation data
Rated insulation voltage U i

input circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC
signalling output / PE 0.5 kV DC

Pollution degree

2

Standards
Product standard

EN 61204-3

Low Voltage Directive

2006/95/EC

EMC directive

2004/108/EC

RoHS directive

2011/65/EC

Electrical safety

EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1

Protective low voltage

SELV

Electromagnetic compatibility
Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)

radiated, radio-frequency, electromagnetic
field
electrical fast transient/burst

IEC/EN 61000-4-3 Level 3 (10 V/m)
IEC/EN 61000-4-4 Level 4
(4 kV / 2.5 kHz)

Level 4 (4 kV / 5 kHz)

surge

IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)

conducted disturbances, induced by radiofrequency fields
power frequency magnetic fields

IEC/EN 61000-4-6 Level 3 (10 V)

voltage dips, short interruptions and voltage
variations
Interference emission

IEC/EN 61000-4-8 Level 4 (30 A/m)
IEC/EN 61000-4-11 dips: >95 % 0.5 ms / >30 % 0.5 ms, interruptions: >95 % 250 ms
IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

limits for harmonic current emissions

IEC/EN 61000-3-2 Class A

„Approvals and marks“ on page 3/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/36

3

CP-T range
Technical data
Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated
Type

CP-T 48/5.0

Input circuit
Rated input voltage U in

3 x 400-500 V AC

Input voltage range

340-575 V AC

CP-T 48/10.0

CP-T 48/20.0

L1, L2, L3

480-820 V DC

3

Frequency range AC

47-63 Hz

Typical input current

0.65 A

1.1 A

1.72 A

Typical power consumption

264 W

535 W

1050 W

Inrush current limiting

20 A

Power failure buffering time

min. 20 ms

Internal input fuse

per phase 2 A / 600 V AC

Power factor correction (PFC)

30 A
min. 15 ms
T3.15 A / 500 V AC

T 5 A / 500 V AC

yes, passive

Discharge current

towards PE < 3.5 mA
input / output < 0.25 mA

Indication of operational states
Output voltage

OUTPUT OK: green LED
OUTPUT LOW: red LED

output voltage OK
output voltage too low

Output circuit
Rated output voltage

48 V DC

L+, L+, L-, L-

Tolerance of the output voltage

0...+1 %

Adjustment range of the output voltage

47-56 V DC

Rated output power

240 W

Rated output current I r

Ta  60 °C 5 A
60 °C < Ta  70 °C 2.5 %/°C
load change statical ±1 % (single mode)

Derating of the output current
Maximum deviation with

480 W

960 W

10 A

20 A
3.5 %/°C

± 5 % (parallel mode)
change of output voltage within the ±0.5 %
input voltage range
Control time

at rated load < 2 ms

Starting time after applying the supply voltage

at I r max. 1 s
with 7000 µF max. 1.5 s

Rise time

at rated load max. 150 ms
with 7000 µF max. 500 ms

Fall time
Residual ripple and switching peaks

max. 150 ms
BW = 20 MHz 100 mV

80 mV

Parallel connection

configurable, to increase
power, up to 2 devices,
min. 0.1 I r - max 0.9 I r)

Series connection

yes, to increase voltage, max. 2 devices

Resistance to reverse feed

approx. 35 V

approx. 63 V

approx. 63 V

combined U/I and
hiccup mode

U/I or hiccup mode,
configurable

hiccup mode /
fold back behavior

Output circuit - No-load, overload and short-circuit behaviour
Characteristic curve of output

to increase power, up
to 2 devices, min. 0.1 I r
- max. 0.9 I r use active
current balancing

Short-circuit protection

continuous short-circuit proof

Short-circuit behaviour

current limiting

Overload protection

hiccup mode

No-load protection

continuous no-load stability

Over temperature protection

yes, automatic recovery after temperature went down

Starting of capacitive loads

7000 µF

3/37 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-T range
Technical data
Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated
Type

CP-T 48/5.0

CP-T 48/10.0

CP-T 48/20.0

General data
Efficiency

typ. 91 %

Duty time

100%

Dimensions (W x H x D)

89 x 124 x 118.8 mm
(3.5 x 4.88 x 4.68 in)

150 x 124 x 118.8 mm
(5.91 x 4.88 x 4.68 in)

275.8 x 124 x 118.8 mm
(10.86 x 4.88 x 4.68 in)

Weight

1.045 kg (2.30 lb)

1.657 kg (3.653 lb)

3.275 kg (7.22 lb)

Material of housing

Metal

Mounting

DIN rail (IEC EN 60715), snap-on mounting without any tool

Mounting position

horizontal

typ. 93 %

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

I

Electrical connection - input circuit / output circuit
Wire size
fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG)

0.2-4 mm² (24-11
AWG) / 0.5-10 mm²
(20-8 AWG)

fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG)
rigid
Stripping length
Tightening torque
Environmental data
Ambient temperature range

8 mm (0.31 in)
input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in)

1 Nm (9 lb.in) /
1.8 Nm (15.6 lb.in)

operation -40…+70 °C

-30…+70 °C

-40…+70 °C

rated load -40…+60 °C

-30…+60 °C

-40…+60 °C

storage -40…+85 °C

-40…+85 °C

-40…+85 °C

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 % without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2G, each along X, Y, Z axes 6 min / cycle

Shock (half-sine) (IEC/EN 60068-2-27)

15G, 11 ms, 3 axes, 6 Faces, 3 times for each face

Isolation data
Rated insulation voltage U i

input circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC

Pollution degree

2

Standards
Product standard

EN 61204-3

Low Voltage Directive

2006/95/EC

EMC directive

2004/108/EC

RoHS directive

2011/65/EC

Electrical safety

EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-16;
EN 60204-1
SELV

Protective low voltage
Electromagnetic compatibility
Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)

radiated, radio-frequency, electromagnetic
field
electrical fast transient/burst

IEC/EN 61000-4-3 Level 3 (10 V/m)
IEC/EN 61000-4-4 Level 4 (4 kV / 5 kHz)

surge

IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)

conducted disturbances, induced by radiofrequency fields
power frequency magnetic fields

IEC/EN 61000-4-6 Level 3 (10 V)

voltage dips, short interruptions and voltage
variations
Interference emission

IEC/EN 61000-4-8 Level 4 (30 A/m)
IEC/EN 61000-4-11 dips: >95 % 0.5 ms / >30 % 0.5 ms
interruptions: >95 % 250 ms
IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

limits for harmonic current
emissions

IEC/EN 61000-3-2 Class A

„Approvals and marks“ on page 3/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/38

3

CP-T range
Technical diagrams, Dimensional drawings
Technical diagrams, dimensions in mm
Output curve at Ta = 25 °C
Uout [V]

28

28

@ 3 x 400V supply

24

16

8
4

Hiccup mode
1

2

3

4

5

6

7

8

2CDC 272 033 F0x09

20

16

2CDC 272 032 F0x09

20

16
12

12
8
4

Hiccup mode

Iout [A]

2

CP-T 24/5.0

4

6

8

10

12

14

@ 3 x 400V supply

24

@ 3 x 500V supply

20

@ 3 x 500V supply

12
8
4

16 Iout [A]

4

CP-T 24/10.0

8

12

16

20

24

28

32 Iout [A]

CP-T 24/20.0 U/I curve
Uout [V]

Uout [V]
U out in V

28

20
2CDC 272 035 F0x09

8
4

Hiccup mode
4

8

12

16

20

24

28

16
Hiccup mode
after 2-5 s overload

12
8
4

32 Iout [A]

8

CP-T 24/20.0 Hiccup mode

16

24

32

40

56

48

64

72

80

32
24
16
8

Hiccup mode
1

Iout in A

CP-T 24/40.0

Uout [V]

@ 3 x 500V supply

40

U/I

20

12

@ 3 x 400V supply

48

24

2CDC 272 037 F0x09

@ 3 x 500V supply

16

56

@ 3 x 400 V supply

@ 3 x 400V supply

24

2CDC 272 027 F0211

28

2

3

4

5

6

7

8

Iout [A]

CP-T 48/5.0

Uout [V]
U out in V

56

@ 3 x 400V supply

48

@ 3 x 400V supply

48

@ 3 x 500V supply

@ 3 x 400 V supply
56

@ 3 x 500V supply

32

40

24
16
8
2

4

6

8

10

12

14

16
8

Hiccup mode
2

16 Iout [A]

CP-T 48/10.0 U/I curve

4

6

8

10

12

14

16 Iout [A]

CP-T 48/10.0 Hiccup mode

U/I

32
Hiccup mode
after 2-5 s overload

24
16
8

4

8

12

16

20

24

28

32

36

40

Iout in A

CP-T 48/20.0

dimensions in mm

2CDC 272 021 F0009

Dimensional drawings

24

2CDC 272 039 F0x09

40

32

2CDC 272 038 F0x09

40

48

2CDC 272 028 F0211

56

CP-T 24/5.0
118.8 4.68‘‘
111.9 4.41‘‘

CP-T 24/20.0, CP-T 48/10.0

3/39 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-T 24/40.0, CP-T 48/20.0

2CDC 272 024 F0009

131 5.16‘‘

275.8 10.86‘‘

124 4.88‘‘

131 5,16‘‘

CP-T 24/10.0, CP-T 48/5.0

124 4,88‘‘

2CDC 272 022 F0009

131 5,16‘‘

150 5,91‘‘

111,9 4,41‘‘

2CDC 272 023 F0009

118,8 4,68‘‘

89 3,5‘‘

124 4,88‘‘

3

28

@ 3 x 400V supply
@ 3 x 500V supply

24

Uout [V]

2CDC 272 034 F0x09

Uout [V]

CP-T range
Technical diagrams
Temperature curve at rated load
Pout [%]

-40

2CDC 272 026 F0211

100
90
80
70
60
50
40
30
20
10
60

70

100
90
80
70
60
50
40
30
20
10
-30

Ta [°C]

3
2CDC 272 030 F0211

Pout [%]

60

70

Ta [°C]

CP-T 24/20.0, CP-T 48/10.0

CP-T 24/40.0, CP-T 48/20.0

Pout [%]

-40

2CDC 272 025 F0211

100
90
80
70
60
50
40
30
20
10
60

70

Ta [°C]

CP-T 24/5.0, CP-T 24/10.0, CP-T 48/5.0

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/40

CP-S and CP-C
Product group picture

3

3/41 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-S and CP-C
Table of contents

CP-S and CP-C range
Product group picture

3/41

Table of contents

3/42

Benefits and advantages

3/43

Operating control

3/44

Ordering details

3/45

Technical data

3/46

Technical diagrams, Dimensional drawings

3/50

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/42

3

CP-S and CP-C
Benefits and advantages
Benefits
1
Integrated power reserve
The new CP-S and CP-C range power supplies feature an integrated power reserve of up to 50 %. No oversized electricity
supply is needed, especially under heavy load conditions.

2
Pluggable connecting terminals
Extended flexibility in operation due to pluggable connecting
terminals (this feature is not offered on all devices).

CP-S range
–– 10 A and 20 A device with front-face selector switch to
adjust r­ ated input voltage range:
110-120 V AC or 220-240 V AC
–– Output voltage fixed at 24 V DC
–– Parallel operation for redundancy

3
Adjustable output voltage
The CP-C range types feature a continuously adjustable
output voltage from 22 to 28 V. Thus, they can be optimally
adapted to the application, e.g. compensating the voltage
drop caused by long line length.

CP-C range
–– Wide range input 110-240 V AC (85-264 V AC, 100-350 V DC)
–– Output voltage adjustable within a range of 22-28 V DC
–– Parallel operation for increased capacity and redundancy
–– Power factor correction (PFC) acc. to EN 61000-3-2
–– Function module pluggable onto the front side

Pluggable function modules
4
The CP-C range power supplies can be equipped with pluggable modules to add additional functions (e.g. messaging
module). Thus, the power supplies can be ideally adapted to
the relevant application.

3/43 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

3

4

2CDC 273 058 F0004

2

2CDC 273 046 F0004

1

2CDC 273 057 F0004

Messaging module CP-C MM:
–– LED for status indication
–– Relay outputs "Input OK" and "Output OK"
–– REMOTE ON/OFF function to switch on and off the
power supply externally
–– Output voltage monitoring is only possible in decoupled
parallel operation

2CDC 273 056 F0004

3

Characteristics
CP-S and CP-C range
–– Output current 5 A, 10 A and 20 A
–– Integrated power reserve of up to 50 %
–– 5 A and 10 A devices with pluggable connecting terminals
–– Approvals / marks
(depending on device, partly pending)
–– A, H, R , K, / a, b

CP-S and CP-C
Operating control

1 OUTPUT L+, L‑: terminals ‑ output
2 Indication of operational states

1

OUTPUT OK: green LED ‑ output voltage OK

3 OUTPUT Adj.: rotary potentiometer ‑ adjustment of output voltage
4 Circuit diagram

2

5 INPUT L, N, PE: terminals ‑ input

3

4

5

1

1 OUTPUT L+, L‑: terminals ‑ output
2 Indication of operational states
OUTPUT OK: green LED ‑ output voltage OK

3 Circuit diagram

2

4 INPUT L, N, PE: terminals ‑ input

3

4

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/44

3

CP-S and CP-C
Ordering details
Description
The power supply units in the CP-S and CP-C range are ABB’s high-end solutions. Designed
with an integrated 50 % power reserve and an efficiency of approximately 89 % these are the
perfect products for all complex, highly reliable applications. All the devices cover the U-I output characteristic and are built with thermal protection which switches off in case of overheating. In particular, the devices of the CP-C range feature a much broader functionality, including
active power factor correction and pluggable function modules.
These products are designed to trip MCB‘s in the 24 V DC output circuit. Coordination tables
are available.
2CDC 271 061 F0004

3

Ordering details - CP-S
Input voltage range

Rated output
voltage / current

Type

Order code

85-264 V AC / 110-350 V DC

24 V DC / 5 A

CP-S 24/5.0

1SVR427014R0000

0.96
(2.11)

85-132 V AC, 184-264 V AC /
220-350 V DC

24 V DC / 10 A

CP-S 24/10.0

1SVR427015R0100

1.07
(2.35)

85-132 V AC, 184-264 V AC /
220-350 V DC

24 V DC / 20 A

CP-S 24/20.0

1SVR427016R0100

2.83
(6.23)

Rated output
voltage / current

Type

Order code

85-264 V AC / 110-350 V DC

24 V DC / 5 A

CP-C 24/5.0

1SVR427024R0000

0.96
(2.11)

85-264 V AC / 110-350 V DC

24 V DC / 10 A

CP-C 24/10.0

1SVR427025R0000

1.34
(2.95)

85-264 V AC / 110-350 V DC

24 V DC / 20 A

CP-C 24/20.0

1SVR427026R0000

3.15
(6.94)

Type

Order code

1 pce

CP-S 24/5.0

2CDC 271 063 F0004

Price

Weight
(1 pce)
kg (lb)

CP-S 24/20.0

Ordering details - CP-C

2CDC 271 065 F0004

Input voltage range

Price
1 pce

Weight
(1 pce)
kg (lb)

CP-C 24/10.0

Description

Price
1 pce

Messaging module for CP-C range power supplies

3/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-C MM

1SVR427081R0000

Weight
(1 pce)
kg (lb)
0.065
(0.14)

CP-S and CP-C
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type
Input circuit - supply circuit
Rated input voltage U in

CP-S

CP-S

Typ. power consumption
Inrush current limiting / I 2 t ( cold start)

CP-C
switch position 115
switch position 230
CP-C
switch position 115
switch position 230

CP-S and CP-C at 110-240 V AC
CP-S at 110-120 V AC
CP-S at 220-240 V AC
CP-C
CP-S

Power failure buffering time
Transient overvoltage protection
Internal input fuse (apparatus protection, not accessible)
Power factor correction (PFC)
Indication of operational states
Output voltage
Output circuit
Rated output voltage
Tolerance of the output voltage
Adjustment range of the output
voltage
Rated output power
Rated output current
Peak output current (power reserve)
Derating
Deviation with

Control time
Starting time after applying
supply voltage
Rise time 10-90 %
Residual ripple and switching peaks
Parallel connection

CP-C 24/10.0

CP-C 24/20.0

CP-S 24/5.0

CP-S 24/10.0

CP-S 24/20.0

L, N

Input voltage range

Frequency range AC
Typical input current

CP-C 24/5.0

CP-C
CP-S

110-240 V AC
110-240 V AC

110-120 V AC
220-240 V AC
85-264 V AC / 100-350 V DC 1)
85-264 V AC / 10085-132 V AC
350 V DC 1)
184-264 V AC / 220-350 V DC 1)
47-63 Hz
2.2-1.2 A
2.6-1.2 A
5.5-2.5 A
4.2-4.0 A
9.0-8.0 A
2.4-2.2 A
4.5-4.0 A
135 W
269 W
538 W
< 23 A / approx.
< 33 A / approx. 0.2 A 2s < 40 A / approx. 1.9 A 2s
0.9 A 2s
< 40 A / approx. 1.8 A 2s < 70 A / approx. 8 A 2s
min. 100 ms
min. 40 ms
min. 40 ms
varistors
4 A (slow-acting)
6.3 A (slow-acting)
12 A (fast-acting)
yes, active
no

OUTPUT OK: green LED V : output voltage OK
L+, L+, L-, L- : short-circuit, no-load and overload proof
24 V DC
CP-C ±1 %
CP-S -1...+5 %
CP-C 22-28 V DC, default setting 24 V ±0.5 %
CP-S fixed
120 W
240 W
480 W
10 A
20 A
Ta m 60 °C 5 A
Ta m 40 °C typ.  7.25 A
typ.  12.25 A
typ.  22.5 A
60 °C < Ta m 70 °C 2.5 % per Kelvin temperature increase
CP-C
load change statical 10-90 % typ. < ±0.05 %
CP-S
load change statical 10-90 % typ. < ±0.1 %
load change dynamical 10-90 % typ. < ±3 %
change of the input voltage of ±10 % typ. < ±0.05 %
typ. < 1 ms
CP-C < 200 ms
< 200 ms
typ. < 200 ms
CP-S
< 250 ms
typ. < 300 ms
CP-C typ. < 30 ms
typ. < 4 ms
typ. < 12 ms
CP-S
typ. < 5 ms
typ. < 15 ms
BW = 20 MHz typ. < 50 mV PP
yes, up to 5 devices, to enable redundancy and to increase
power, current not symmetrical (CP-S only redundancy)

Series connection
Resistance to reverse feed

yes, to increase voltage, for decoupling refer to the application manual
approx. 35 V DC

Output circuit - No-load, overload and short-circuit behaviour
Characteristic curve of output
Current limiting at short circuit
Short-circuit protection
Overload protection
Starting of capacitive loads
General data
Power dissipation
Efficiency
Discharge current for PE
MTBF

see also U/I- and I/T-characteristic curves
U/I characteristic curve with power reserve
approx. 11 A
approx. 19 A
approx. 25 A
continuous short-circuit stability
thermal protection
unlimited

Dimensions (W x H x D)
Weight
Minimum distance to other units
Degree of protection
Material of housing
Protection class (EN 61140)
Mounting
Mounting position

typ. < 15 W
typ. < 29 W
typ. 89 %
< 3.5 mA
CP-C 500.000 h
CP-S 350.000 h
56.5 (60 2)) x 130 x 135.5
90 (93.5 2)) x 130 x 135.5
mm (2.22 (2.36 2)) x 5.12 x
mm (3.54 (3.68 2)) x 5.12 x
5.35 in)
5.35 in)
CP-C approx. 0.96 kg (2.12 lb)
approx. 1.34 kg (2.95 lb)
CP-S
approx. 1.07 kg (2.36 lb)
horizontal / vertical 10 mm / 80 mm (0.39 in / 3.15 in)
housing / terminals IP20 / IP20
housing shell / cover aluminium / zinc-coated sheet steel
I
DIN rail (IEC/EN 60715), snap-on mounting
horizontal

typ. < 58 W

200 (203.5 2)) x 130 x 135.5
mm (7.87 (8.01 2)) x 5.12 x
5.35 in)
approx. 3.15 kg (6.94 lb)
approx. 2.83 kg (6.23 lb)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/46

3

CP-S and CP-C
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type
Electrical connection - Input circuit
Wire size

3

Stripping length
Tightening torque
Electrical connection - Output circuit
Wire size

Stripping length
Tightening torque
Environmental data
Ambient temperature range

Pollution degree (IEC/EN 60950-1; EN 50178)
Overvoltage category (IEC/EN 60950-1; EN 50178)
Standards
Product standard
Low Voltage Directive
EMC Directive
Electrical safety
Protective low voltage
Electromagnetic compatibility
Interference immunity to
electrostatic discharge
radiated, radio-frequency, electromagnetic field
electrical fast transient / burst
surge
conducted disturbances, induced by radiofrequency fields

3)

CP-S 24/20.0

3)

3)

3)

3)

-

2.5-10 mm 2 (14-8 AWG)
0.5-10 mm 2 (20-8 AWG)
0.5-16 mm 2 (20-6 AWG)
12 mm (0.47 in)
1.2-1.5 Nm
2.5-10 mm 2 (14-8 AWG)
0.5-10 mm 2 (20-8 AWG)
0.5-16 mm 2 (20-6 AWG)
12 mm (0,47 in)
1.2-1.5 Nm

operation -25...+70 °C
rated load 0...+60 °C (without derating)
storage -40...+85 °C
93 % at +40 °C, no condensation
3K3

Power-frequency withstand voltage test (test voltage)
(routine test / type test)

2)

CP-C 24/20.0

CP-S 24/10.0

fine-strand with wire end ferrule 0.12-2.5 mm 2 (26-14 AWG)
fine-strand without wire end ferrule
rigid
8 mm (0.31 in)
0.4 Nm

Rated impulse withstand voltage U imp between all isolated
circuits (IEC/EN 60950-1; EN 50178)

1)

CP-C 24/10.0

CP-S 24/5.0
fine-strand with wire end ferrule 0.2-2.5 mm 2 (24-14 AWG)
fine-strand without wire end ferrule
rigid
7 mm (0.28 in)
0.4 Nm

Damp heat (IEC/EN 60068-2-3)
Climatic category (IEC/EN 60721)
Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)
Isolation data
Rated insulation voltage U i between all isolated circuits
(IEC/EN 60950-1; EN 50178)

Interference emission
high-frequency radiated
high-frequency conducted

CP-C 24/5.0

input / output
input / PE
output / PE
input / output
input / PE
output / PE
input / output
input / PE
output / PE

300 V
300 V
50 V
4 kV; 1.2/50 µs
2.5 kV; 1.2/50 µs
500 V; 1.2/50 µs
1.5 kV AC / 3.0 kV AC
1.5 kV AC / 3.0 kV AC
500 V DC / 500 V DC
2
II
IEC/EN 61204
2006/95/EC
2004/108/EC
EN 50178, EN 60950, UL 60950, UL 508
SELV (EN 60950)

IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6

IEC/EN 61000-6-2
Level 4 (8 kV / 15 kV)
Level 3 (10 V/m)
Level 4 (4 kV)
Level 4 (2 kV symmetrical, level 3 - 3 kV asymmetrical)
Level 3 (10 V)

IEC/EN 61000-6-3
IEC/CISPR 22; EN 55022 Class B
IEC/CISPR 22; EN 55022 Class B

at U > 264 V use additionally an appropriate external fuse
with lateral screw
pluggable connecting terminals, actuate only when power is off

„Approvals and marks“ on page 3/4.

3/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-S and CP-C
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type
Input circuit - Supply circuit
Rated input voltage U in
Input voltage range
Power consumption
Input circuit - Control circuit
Kind of triggering
Control input, control function
Threshold "Switching-off power supply unit"
Threshold "Switching-on power supply unit"
Input current
Maximum cable length to the control input
Measuring circuit - INPUT

CP-C MM
110-240 V AC / 100-350 V DC
70-264 V AC / 80-350 V DC
2.5 VA / 1.5 W
volt-free triggering
Remote OFF remote off
R  1 k
R  10 k
typ. 1 mA (200 mA for 200 µs)
25 m - 100 pF/m
powered by the input circuit of the power supply unit

Monitoring function

undervoltage monitoring of input voltage of the power supply
unit
85 V AC / 90 V DC
AC: typ. -8 % / DC -30 %
-5 % at AC and DC
typ. < 50 ms
powered by the output circuit of the power supply unit
undervoltage monitoring of output voltage of the power supply
unit
20 V DC
typ. 5 %
±1 %
typ. < 10 ms

Thresholds
Hysteresis, related to the threshold value
Accuracy, tolerance
Maximum measuring cycle
Measuring circuit - OUTPUT
Monitoring function
Thresholds
Hysteresis, related to the threshold value
Accuracy, tolerance
Maximum measuring cycle
Indication of operational states
Remote off
Status of power supply input
Status of power supply output

REMOTE OFF: green LED V : „REMOTE OFF“ input R  1k
Input OK: green LED V : relay „INPUT OK“ energized
OUTPUT OK: green LED V : relay „OUTPUT OK“ energized

Output circuits
Kind of output
Operating principle
Contact material
Rated voltage (VDE 0110, IEC/EN 60947-1)
Minimum switching voltage / Minimum switching current
Maximum switching voltage / Maximum switching current
Rated operating current I e (IEC/EN 60947-1)
AC-12 (resistive) at 230 V
AC-15 (inductive) at 230 V
DC-12 (resistive) at 24 V
DC-13 (inductive) at 24 V
Mechanical lifetime
Electrical lifetime
Short circuit proof,
n/c contact
maximum fuse rating
n/o contact
General data
Duty time
Dimensions (W x H x D, when mounted)
Weight
Degree of protection
housing / terminals
Material of housing
Protection class (EN 61140)
Mounting
Mounting position
Electrical connection
Wire size
fine-strand with wire end ferrule
fine-strand without wire end ferrule
rigid
Stripping length
Tightening torque

11-12/14, 21-22/24
relays, 2 x 1 c/o contacts
closed-circuit principle
AgNi
250 V
24 V / 10 mA
250 V / 1 A
1A
1A
1A
1A
30 x 10 6 switching cycles
0.1 x 10 6 switching cycles
2 A, gL
2 A, gL
100 %
56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 in)
0.065 kg (0.14 lb)
IP20 / IP20
Plastic
II
snap-on mounting, without any tool
plugged onto the power supply unit
0.2-2.5 mm 2 (24-14 AWG)
0.2-4 mm 2 (24-12 AWG)
7.5 mm (0.3 inch)
0.4-0.6 Nm

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/48

3

CP-S and CP-C
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type
Environmental data
Ambient temperature range

3

CP-C MM
operation -25...+70 °C
storage -40...+85 °C
93 % at +40 °C, no condensation
3K3

Damp heat (IEC/EN 60068-2-3)
Climatic category (IEC/EN 60721)
Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)
Isolation data
Rated insulation voltage U i (IEC/EN 60974-1, EN 50178, VDE 0160)
Protective separation (EN 50178, EN 60950) supply / measuring circuits / relay
outputs
Rated impulse withstand voltage U imp between all isolated circuits (IEC 664, VDE
0110)
Test voltage between all circuits (type test)
Pollution degree (EN 60950)
Overvoltage category (EN 60950)
Standards
Product standard
Low Voltage Directive
EMC Directive
Electrical safety
Elektromagnetic compatibility
Interference immunity to
electrostatic discharge
IEC/EN 61000-4-2
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3
electrical fast transient / burst
IEC/EN 61000-4-4
surge
IEC/EN 61000-4-5
conducted disturbances, induced by radio-frequency
fields
Interference emission
high-frequency radiated
high-frequency conducted

IEC/EN 61000-4-6

250 V
yes
4 kV; 1.2/50 µs
2.5 kV AC
2
II
IEC/EN 61204
2006/95/EC
2004/108/EC
EN 50178, EN 60950, UL 60950, UL 508
IEC/EN 61000-6-2
Level 3 and 4 (6 kV / 8 kV)
Level 3 (10 V/m)
Level 4 and 2 (4 kV power input / 1 kV control input)
Level 3 and 2 (4 kV symmetrical power input / 1 kV control
input)
Level (10 V)

IEC/EN 61000-6-3
IEC/CISPR 22; EN 55022 Class B
IEC/CISPR 22; EN 55022 Class B

„Approvals and marks“ on page 3/4.

3/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-S and CP-C
Technical diagrams, Dimensional drawings
Technical diagrams
Temperature curve at Uout = 24 V DC

Uout [V]

Iout [A]

Uout [V]

Iout [A]

Iout [A]

Iout [A]

CP-C 24/10.0

CP-S 24/10.0
Uout [V]

2CDC 272 027 F0b04

Uout [V]

2CDC 272 004 F0b04

CP-S 24/5.0, CP-C 24/5.0

CP-S 24/10.0, CP-C 24/10.0

Iout [A]

2CDC 272 028 F0b04

2CDC 272 005 F0b04

Iout [A]

CP-C 24/20.0

CP-S 24/20.0, CP-C 24/20.0

Ta [°C]

dimensions in mm
60,0 [2.36”]

93,5 [3.68”]

203,5 [8.01”]

56,5 [2.22”]

90,0 [3.54”]

200,0 [7.87”]



135,5 [5.33”]



130,0 [5.12”]

130,0 [5.12”]



CP-S 24/10.0		
CP-C 24/10.0		

CP-S 24/20.0
CP-C 24/20.0

56,5 [2.22”]

24

]

4”

.9

[0

2CDC 272 016 F0b07

54 [2.13”]

CP-S 24/5.0		
CP-C 24/5.0		
CP-A RU

2CDC 272 015 F0b07

144,5 [5.69”]
137,0 [5.39”]

130,0 [5.12”]

Dimensional drawings

Ta [°C]

Iout [A]

Uout [V]

CP-S 24/20.0

3

2CDC 272 006 F0204

Ta [°C]

CP-C 24/5.0

2CDC 272 075 F0204

Iout [A]

CP-S 24/5.0

2CDC 272 088 F0204

Iout [A]

2CDC 272 026 F0b04

Output curve at 25 °C

Uout [V]

2CDC 272 003 F0b04

Output curve at 25 °C

CP-C MM

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/50

Redundancy units
Ordering details
Ordering details

2CDC 271 003 F0005

Description

3
CP-A RU + CP-A CM

suitable for decoupling of Type
two CP-24 V DC power
supply units or suitable
for decoupling of CP-E
power supply units

Order code

Price
1 pce

Weight
(1 pce)
kg (lb)

2 inputs each up to 20 A and 1
output up to 40 A

 40 V and M 5 A

CP-A RU

1SVR427071R0000

0.89
(1.96)

Control module for CP-A RU
redundancy units

-

CP-A CM

1SVR427075R0000

0.063
(0.14)

2 inputs each up to 2.5 A and 1
output up to 5 A

 35 V and < 5 A

CP-RUD

1SVR423418R9000

0.15
(0.33)

2CDC 271 010 F0006

Ordering details - CP-D RU for decoupling of two CP‑D power supply units
Input voltage
range

Rated input
current

Rated output voltage / Type
current

9-35 V DC

2x5A

24 V DC /
1 x 10 A

2CDC 271 006 F0003

CP-A RU

2CDC 271 010 F0006

CP-RUD

CP-D RU

3/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-D RU

Order code

1SVR427049R0000

Price

Weight
(1 pce)
kg (lb)
0.075
(0.165)

Redundancy units
Technical data
Type
Input circuit - Supply circuit
Rated input voltage U in
Input voltage range per channel
Rated input current Iin per channel
Maximum input current per channel
Transient overvoltage protection
Output circuit
Rated output voltage U out
Voltage drop
Rated output current I out
Output ratings per channel

CP-A RU

2)

in combination with CP-A CM
(+/ -, +/ -)

24 V DC
10-28 V DC
1-20 A
30 A for 300 s
yes

13-28 V DC

(++/--)
24 V DC
typ. 0.6 V, max. 0.9 V
1-40 A
Ta = 60 °C 10-28 V DC / 40 A
13-28 V DC / 40 A
Ta = 70 °C 10-28 V DC / 30 A
13-28 V DC / 30 A
60 °C < Ta m 70 °C 2.5 % per Kelvin temperature increase
60 A for 300 s
< 40 V

Derating
Peak output current
Resistance to reverse feed
General data
Dimensions (W x H x D)
Weight
Minimum distance to other units
horizontal / vertical
Degree of protection
housing / terminals
Material of housing
housing shell / cover
Protection class
Mounting
Mounting position
Electrical connection - Input circuit / Output circuit
Wire size
fine-strand with wire end ferrule
fine-strand without wire end ferrule
rigid
Stripping length
Tightening torque
Environmental data
Ambient temperature range
operation
rated load
storage
Damp heat (IEC/EN 60068-2-3)
Climatic category (IEC/EN 60721)
Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)
Isolation data
Insulation voltage
between input / output / housing
Pollution degree (EN 50178)
Standards
Product standard
Low Voltage Directive
EMC Directive
Electrical safety
Electromagnetic compatibility
Interference immunity to
electrostatic discharge
IEC/EN 61000-4-2
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3
electrical fast transient / burst
IEC/EN 61000-4-4
surge
IEC/EN 61000-4-5
conducted disturbances, induced by radioIEC/EN 61000-4-6
frequency fields
Interference emission
high-frequency radiated
IEC/CISPR 22 / EN 55022
high-frequency conducted
IEC/CISPR 22 / EN 55022
1)

CP-A RU

56.5 (60 1)) x 130 x 135.5 mm; (2.22 (2.36 1)) x 5.12 x 5.35 in)
0.89 kg (1.96 lb)
10 mm / 50 mm (0.39 in / 1.97 in)
IP20 / IP20
aluminium / zinc-coated sheet steel
III 2)
DIN rail (IEC/EN 60715)
horizontal
2.5-10 mm 2 (14-8 AWG)
0.5-10 mm 2 (20-8 AWG)
0.5-16 mm 2 (20-6 AWG)
12 mm (0.47 in)
1.2-1.5 Nm
-25...+70 °C
-25...+60 °C (without derating)
-40...+85 °C
93 % at 40 °C, no condensation
3K3

500 V AC (routine test)
2
IEC/EN 61204
2006/95/EC
2004/108/EC
EN 50178, EN 60950, UL 60950, UL 508
IEC/EN 61000-6-2
Level 3 (air discharge ±8 kV, contact discharge ±6 kV)
Level 3 (10 V/m)
Level 3 (±2 kV)
Level 1 (±0.5 kV)
Level 3 (10 V)
IEC/EN 61000-6-3
Class B
Class B

incl. lateral screw
This device is designed for connection to a safety extra-low voltage source. If no safety extra-low voltage is used at the input side, the lateral screw can be used for grounding
of the housing (protection class I).

„Approvals and marks“ on page 3/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/52

3

Redundancy units
Technical data

3

Type
Input circuit - Supply circuit
Rated input voltage U in
Input voltage range
Rated input current
at rated sense load and 24 V DC
Power consumption
at 24 V DC
Measuring circuit
Monitoring function
Measuring voltage
Thresholds
Hysteresis, related to the threshold value
Accuracy, tolerance
Maximum measuring cycle
Indication of operational states
Status of input 1
IN 1: green LED
Status of input 2
IN 2: green LED
Output status
OUT: green LED
Output circuit
Kind of output
Contact material
Operating principle
Rated operational voltage U e (IEC/EN 60947-1, VDE 0110)
Minimum switching voltage / Minimum switching current
Maximum switching voltage / Maximum switching current
Rated operational current I e
AC-12 (resistive) at 230 V
(IEC/EN 60947-5-1)
AC-15 (inductive) at 230 V
DC-12 (resistive) at 24 V
DC-13 (inductive) at 24 V
Mechanical lifetime
Electrical lifetime
Rating according UL 508
General purpose (GP) 250 V AC
Maximum fuse rating to achieve
n/o contact
short-circuit protection
n/c contact
Sense output (+, +, -)
Sense output voltage
Sense output current
Maximum fuse rating
General data
Duty time
Dimensions (W x H x D, when mounted)
Material of housing
Weight
Degree of protection
Protection class
Mounting
Mounting position
Electrical conection
Wire size

CP-A CM
24 V DC
13-28 V DC
120 mA
approx. 1 W
11-12/14, 21-22/24
undervoltage monitoring
rated operational voltage
14-28 V
fix: 3-5 %
10 % of full-scale value
6 ms
: voltage at input 1 > than threshold 1 = no faults present
: voltage at input 2 > than threshold 2 = no faults present
: U OUT > 3 V = no faults present
+, +, relays, 2 x 1 c/o contact
AgNi
closed-circuit principle
250 V
24 V / 10 mA
250 V / 1 A
1A
1A
1A
1A
30 x 10 6 switching cycles
0.1 x 10 6 switching cycles
1A
2 A, gL
2 A, gL
1 SVR 427 075 R0000
13-28 V DC
0.1 A
For applications acc. UL the sense output shall be provided
with a listed DC fuse 3 A

100 %
56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 in)
plastic
0.063 kg (0.14 lb)
housing / terminals IP20 / IP20
II
snap-on mounting, without any tool
plugged onto the redundancy unit CP-A RU
fine-strand with wire end ferrule
0.2-2.5 mm 2 (24-14 AWG)
fine-strand without wire end ferrule
rigid 0.2-4 mm 2 (24-12 AWG)
7.5 mm (0.3 in)
0.4-0.6 Nm

Stripping length
Tightening torque
Isolation data
Rated insulation voltage U i (IEC/EN 60947-1, EN 50178, VDE 0160)
Rated impulse withstand voltage U imp (type test) between all circuits
(IEC 664, VDE 0110)
Power-frequency withstand voltage test (routine test) between all circuits
Protective separation (EN 50178) between input and output
Pollution degree
Overvoltage category
Environmental data
Ambient temperature range
operation
storage
Damp heat (IEC/EN 60068-2-3)
Climatic category (IEC/EN 60721)
Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)
3/53 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

250 V
2.5 kV
1.2 kV AC
yes
2
II
-25...+70 °C
-40...+85 °C
93 %at 40 °C, no condensation
3K3

Redundancy units
Technical data
Type
Input circuit - Supply circuit
Rated input voltage U in

CP-RUD
A: U1+/-U ; B: U2+/-U
24 V DC

Input voltage range

5-35 V DC

Rated input current I in per channel

0.5-2.5 A

Maximum input current per channel

10 A for 300 s

Transient overvoltage protection

no

Output circuit
Rated output voltage U out

24 V DC

Voltage drop

typ. 0.6 V, max. 0.7 V

Rated output current I out

0.5-5 A

Peak output current

20 A for 150 s

Resistance to reverse feed

< 35 V

General data
Dimensions (W x H x D)

22.5 x 78 x 100 mm (0.89 x 3.07 x 4.02 in)

L+, L+, L+, L-, L-, L-

Weight
Minimum distance to other units

0.135 kg (0.30 lb)
horizontal / vertical 10 mm / 10 mm (0.39 in / 0.39 in)

Degree of protection

housing / terminals IP20 / IP20

Material of housing

housing shell / cover plastic / plastic

Protection class

-

Mounting

DIN rail (IEC/EN 60715)

Mounting position

horizontal

Electrical connection - Input circuit / Output circuit
Wire size
fine-strand with wire end ferrule 2 x 0.75-2.5 mm 2 (2 x 18-14 AWG)
fine-strand without wire end ferrule
rigid 2 x 0.5-4 mm 2 (2 x 20-12 AWG)
Stripping length

7 mm (0.28 in)

Tightening torque

0.6-0.8 Nm

Environmental data
Ambient temperature range

operation -20...+60 °C
rated load -20...+60 °C
storage -40...+85 °C
93 % at 40 °C, no condensation

Damp heat (IEC/EN 60068-2-3)
Climatic category (IEC/EN 60721)

-

Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)
Isolation data
Insulation voltage

between input / output / housing -

Pollution degree (EN 50178)

2

Standards
Product standard
Low Voltage Directive

2006/95/EC

EMC Directive

2004/108/EC

Electrical safety

EN 50178

Electromagnetic compatibility
Interference immunity to
electrostatic discharge

IEC/EN 61000-6-2
IEC/EN 61000-4-2 Level 3 (air discharge ±8 kV, contact discharge ±6 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 Level 3 (10 V/m)

electrical fast transient/burst

IEC/EN 61000-4-4 Level 3 (w2 kV)
IEC/EN 61000-4-5 Level 1 (w0.5 kV)
IEC/EN 61000-4-6 Level 3 (10 V)

surge
conducted disturbances, induced by radiofrequency fields
Interference emission

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22 / EN 55022 Class B

high-frequency conducted

IEC/CISPR 22 / EN 55022 Class B

1)
2)

incl. lateral screw
This device is designed for connection to a safety extra-low voltage source. If no safety extra-low voltage is used at the input side, the lateral screw can be used for grounding
of the housing (protection class I).

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/54

3

Redundancy units
Technical data
Type

3

CP-D RU

Input circuit - Supply circuit
Rated input voltage U in

IN 1 + + -, IN 2 + + 24 V DC

Input voltage range

9-35 V DC

Rated input current I in per channel

5A

Maximum input current per channel

10 A for 300 s

Transient overvoltage protection

no

Output circuit
Rated output voltage U out

24 V DC

Voltage drop

typ. 0.5 V

Rated output current I out

10 A

Resistance to reverse feed

< 35 V

General data
MTBF

on request

OUT + + +, - - -

Duty time

100 %

Dimensions (W x H x D)

product dimensions 35 x 91 x 56.5 mm (1.38 x 3.58 x 2.22 in)
packaging dimensions 134 x 94 x 48 mm (5.28 x 3.70 x 1.89 in)

Weight

net weight 0.075 kg (0.165 lb)
gross weight 0.130 kg (0.286 lb)

Material of housing

plastic

Mounting

DIN rail, snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm (0.98 in) / 25 mm (0.98 in)

Electrical connection - Input circuit / Output circuit
Wire size
fine-strand with (out)wire end ferrule 0.2-2.5 mm 2 (24-14 AWG)
rigid 0.2-2.5 mm 2 (24-12 AWG)
Stripping length

7.0 mm (0.28 in)

Tightening torque

0.67 Nm (6 Ib.in)

Environmental data
Ambient temperature range

operation -40...+70 °C
storage -40...+85 °C

Relative humidity

RH at 40 °C 20-95 %, no condensation

Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)

Mounting by rail:
10-500 Hz, 2 G, along X, Y, Z each axis, 60 min for each axis
15 G, 11 ms, 3 axis, 6 faces, 3 times for each face

Standards
Product standard

IEC/EN 61204-3

Low Voltage Directive

2006/95/EC

EMC Directive

2004/108/EC

RoHS Directive

2011/65/EC

Electromagnetic compatibility
Interference immunity to

EN 55024

electrostatic discharge

IEC/EN 61000-4-2 Level 3, air discharge 8 kV, contact discharge 4 kV

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 Level 3, 10 V/m

electrical fast transient/burst

IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 Level 3, 10 V

Interference emission

EN 55022

high-frequency radiated

IEC/CISPR 22 / EN 55022 Class B

high-frequency conducted

IEC/CISPR 22 / EN 55022 Class B

3/55 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Redundancy units
Dimensional drawings

35.0 1.38”

IN1

-

IN2

-

67.0 2.64”

+

-

OUT

-

-

57.5 2.26”

2CDC272033F0010

+

49.0 1.93”

+

32.1 1.26”

91.0 3.58”

44.5 1.75”

56,5 [2.22”
]

CP-D RU

24

]

4”

.9

[0

CP-A CM

144,5 [5.69”]
144,5 [5.69”]
137,0 [5.39”]

3

2CDC 272 016 F0b07

IN2

54 [2.13”]

IN1

+ + + +

109,5
102

[4.31“]

60,0 [2.36”]

[4.02“]

56,5 [2.22”]

22,5

137,0 [5.39”]

93,5 [3.68”]

[.886“]

90,0 [3.54”]

203,5 [8.01”]

60,0 [2.36”]

93,5 [3.68”]

56,5 [2.22”]

90,0 [3.54”]

200,0 [7.87”]





CP-RUD

135,5 [5.33”]

130,0 [5.12”]

130,0 [5.12”]

130,0 [5.12”]

130,0 [5.12”]

[3.94“]

2CDC 272 015 F0b07

100

78 [3.07“]

130,0 [5.12”]
135,5 [5.33”]



2CDC 252 188 F0b05





CP-A RU

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/56

CP-ASI range
Product group picture

3

3/57 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-ASI range
Table of contents

CP-ASI
Product group picture

3/57

Table of contents

3/58

Benefits and advantages

3/59

Ordering details

3/60

Technical data

3/61

Technical diagrams

3/63

Dimensional drawings

3/64

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/58

3

CP-ASI range
Benefits and advantages

3

Characterics
–– Rated output voltage 30.5 V DC for ASI-bus
–– Rated output current up to 8.0 A
–– High efficiency of up to 92 % 1)
–– Infrared addressing mode 2)
–– Low power dissipation and low heating
–– Free convection cooling (no forced cooling with ventilators)
–– Ambient temperature range during operation -10…70 °C 3)
– – Open-circuit, overload and short-circuit stable
– – Integrated input fuse
– – Tool-free mounting on DIN rail as well as demounting
– – LEDs for the indication of operational states
– – Approval4): A /Mark: a
1)
2)
3)
4)

Efficiency is depending on device
Except CP-ASI/4.0 DC/DC
Ambient temperature range CP-ASI/4.0 DC/DC -25…70°C
Approvals are related to rated input voltage Uin

1
2

1 Output +, -, +, -, SHIELD: output terminals
2 Signalling contact 11-12: ground fault signalling terminals
3 Indication of operational states

AS-I OK: green LED - output voltage OK
4 Configuration of operation mode Jumper

3
4

5
6
7
8
9

10

3/59 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

5 Indication of operational states
IR ADDRESSING ON: red LED - infrared addressing mode active
6 Test and reset button
7 Indication of operational states
GROUND FAULT: red LED - ground fault detected
8 Circuit diagram
9 Input voltage selector Adjustment of input voltage
10 Input L, N, PE: input terminals

CP-ASI range
Ordering details

Description

2CDC 271 002 S0012

The CP-ASI power supply range is specifically designed with integrated data decoupling for
the supply of AS-Interface systems.
Up to 62 slaves (binary I/O devices) can be supplied with a single two-conductor cable.
The configurable IR addressing mode allows the easy assign of new ID addresses by means of
an external infrared programming unit.

CP-ASI/2.8

Ordering details

2CDC 271 003 S0012

Input Voltage Range

Rated
Output
Voltage

Rated
Output
Current

Type

Order code

Price

85-132 V AC, 184-264 V AC

30.5 V DC

2.8 A

CP-ASI/2.8

1SVR427090R0280

0.495 (1.091)

85-132 V AC, 184-264 V AC

30.5 V DC

4.0 A

CP-ASI/4.0

1SVR427090R0400

0.653 (1.440)

18-32.4 V DC

30.5 V DC

4.0 A

CP-ASI/4.0 DC/DC

1SVR427095R0400

0.488 (1.076)

85-132 V AC, 184-264 V AC

30.5 V DC

8.0 A

CP-ASI/8.0

1SVR427090R0800

0.897 (1.978)

1 pce

Weight
(1 pce)
kg (lb)

2CDC 271 004 S0012

CP-ASI/4.0 DC/DC

2CDC 271 005 S0012

CP-ASI/4.0

CP-ASI/8.0

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/60

3

CP-ASI range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type
Input circuit - Supply circuit
Rated input voltage U in
Input voltage range

3

CP-ASI/2.8
switch position 115 V 100-120 V AC
switch position 230 V 220-240 V AC
switch position 115 V 85-132 V AC
switch position 230 V 184-264 V AC

47-63 Hz
switch position 115 V 2.0 A
switch position 230 V 0.9 A
Allowed voltage between input and earth (ground)
CP-ASI/4.0 DC/DC:
Allowed input ripple voltage
CP-ASI/4.0 DC/DC:
Continuous input voltage with no damage to the DC/DC converter
Turn-on voltage
Shut-down voltage
Typical power consumption
94 W
Inrush current limiting / I²t (cold start)
< 20 A (132 V AC) /
approx. 1.5 A²/s
< 38 A (264 V AC) /
approx. 1.8 A²/s
Discharge current towards PE
Power failure buffering time

at 115 V AC
at 230 V AC

Transient overvoltage protection
Reverse input polarity protection
Internal input fuse
External fusing (not necessary, but recommended)

Indication of operational states
Output voltage
IR addressing mode
Overload
Output circuit
Rated output voltage
Rated output power
Tolerance of the output voltage
Adjustment range of the output voltage
Rated output current I r

CP-ASI/8.0

CP-ASI/4.0 DC/DC

L, N

Frequency range AC
Typical input current

Power factor correction (PFC)

CP-ASI/4.0

at 115 V AC
at 230 V AC

184-264 V AC /
240-300 V DC

184-264 V AC

2.7 A
6.0 A
1.3 A
2.8 A
max. 60 V DC / 42.4 V AC
max. 5 Vpp, 47 Hz - 40 kHz

135 W
< 44.7 A (120 V AC)
/ approx. 3.7 A²/s
< 49.3 A (132 V AC)
/ approx. 4.6 A²/s
< 49.7 A (230 V AC)
/ approx. 2.5 A²/s
< 57.5 A (264 V AC)
/ approx. 3.3 A²/s

261 W
< 12 A (100 V AC) /
approx. 1.0 A²/s
< 14 A (120 V AC) /
approx. 1.5 A²/s
< 24 A (220 V AC) /
approx. 1.4 A²/s
< 27 A (240 V AC) /
approx. 1.6 A²/s

24 V DC
18.0-32.4 V DC
5.6 A
max. 36.0 V DC
typ. 17.5 V DC
typ. 14.0 V DC
typ. 35 V DC
132 W
< 1.8 A / approx.
1.0 A²/s
-

< 3.5 mA
max. 0.5 ms
min. 35 ms
min. 40 ms
min. 20 ms
min. 40 ms
min. 30 ms
varistors
CP-ASI/4.0 DC/DC: included, unit does not start at reversed polarity
8 A slow acting /
3.15 A slow acting / 8 A slow acting /
10 A slow acting
250 V AC
250 V AC
250 V AC
circuit breaker with C characteristic min 6 A, or alternatively
10 A with B characteristic
0.58
0.53
0.53
0.48
-

AS-I OK LED green
IR ADDRESSING ON LED red
OVERLOAD
+,30.5 V DC
85 W
±3%
Ta m 60 °C 2.8 A

-

LED red

122 W

244 W

122 W

4.0 A

8.0 A

4.0 A

Derating of the output current

60 °C < Ta m 70 °C 2.5 %/°C
Signalling contact for ground fault
CP-ASI/4.0: max. 25 V AC or 60 V DC, 0.5 A
Control time
< 2 ms
Starting time after applying the supply voltage
max. 400 ms
max. 700 ms
max. 500 ms
Rise time
max. 100 ms
at rated load with 5 mF Residual ripple
BW = 500 kHz typ. < 50 mVpp
Switching peaks

max. 1 s (typ. 650 ms)
typ. 100 ms
typ. 200 ms

BW = 20 MHz typ. < 100 mVpp

Output circuit - No-load, overload and short-circuit behaviour
Characteristic curve of output

U/I characteristic curve

Short-circuit protection

continuous short-circuit stability

Overtemperature protection
No-load protection

CP-ASI/4.0 DC/DC: yes, automatic recovery after temperature went down
continuous no-load stability

Combined U/I
characteristic
curve and hiccup
mode
temporary shortcircuit stability
-

U/I characteristic
curve

continuous shortcircuit stability
Short-circuit behaviour
continuation with output power limiting
continuation with
output power
limiting
Current limiting at short circuit
min / max 3.2 A / 4.6 A
4.2 A / 6.5 A
12 A / 25 A (max. 5 s)
5.0 A / 9.0 A
Overload protection
output power limiting
temporary output
output power
power limiting
limiting
Overtemperature, overload and short circuit behaviour
CP-ASI/8.0: at 8.4 A < I max < 12 A continuous current for 2-5 s, afterwards safety switch-off

3/61 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-ASI range
Technical data
Type
General data

CP-ASI/2.8

MTBF
Power dissipation
Efficiency
Duty time
Dimensions (W x H x D)

product dimensions
packaging dimensions

Weight

net weight
gross weight

Material of housing
Mounting
Mounting position
Minimum distance to other units
horizontal / vertical
Degree of protection
housing / terminals
Protection class
Electrical connection
Wire size
fine-strand with wire end ferrule
fine-strand without wire end ferrule
rigid
Stripping length
Tightening torque
Environmental data
Ambient temperature range
operation
rated load
storage
Vibration (sinusoidal)
(IEC/EN 60068-2-6)
sinusoidal (IEC/EN 60068-2-6)
random (IEC 60068-2-64)
Shock (half-sine) (IEC/EN 60068-2-27)
Isolation data
Rated insulation voltage U i
input circuit / output circuit
(IEC/EN 60950-1, EN 50178)
input / PE
output / PE
shield / output
shield / PE
Rated impulse withstand voltage U imp
input / output
(EN 50178)
input / PE
output / PE
Power-frequency withstand voltage
input / output
test (test voltage) (routine test /
type test)
input / PE
Pollution degree (IEC/EN 60950-1)
Overvoltage category (UL/IEC/EN 60950-1)
Standards
Low Voltage Directive
EMC directive
RoHS directive
Electrical safety
Protective low voltage
Electromagnetic compatibility
Interference immunity to
electrostatic discharge
radiated, radio-frequency,
electromagnetic field
electrical fast transient/burst

CP-ASI/4.0

CP-ASI/8.0

on request
typ. < 9.1 W
typ. < 13.5 W
typ. < 21.2 W
(230 V AC, 2.8 A)
(230 V AC, 4.0 A)
(230 V AC, 8.0 A)
typ. 90.5 %
typ. 90 %
typ. 92.0 %
100 %
49 x 131 x 107 mm
73 x 131 x 107 mm
91 x 131 x 107 mm
(1.93 x 5.16 x 4.21 in) (2.87 x 5.16 x 4.21 in) (3.58 x 5.16 x 4.21 in)
151 x 65 x 140 mm
151 x 98 x 140 mm
151 x 120 x 140 mm
(5.94 x 2.56 x 5.51 in) (5.94 x 3.86 x 5.51 in) (5.94 x 4.72 x 5.51 in)
0.495 kg (1.019 lb) 0.653 kg (1.440 lb) 0.897 kg (1.997 lb)
0.568 kg (1.252 lb) 0.750 kg (1.653 lb) 1.015 kg (2.238 lb)
metal
DIN rail (IEC/EN 60715), snap-on mounting without any tool
horizontal
15 mm / 25 mm (0.59 / 0.99 in)
IP20 / IP20
I

40 x 131 x 107 mm
(1.58 x 5.16 x 4.21 in)
151 x 65 x 140 mm
(5.94 x 2.56 x 5.51 in)
0.488 kg (1.076 lb)
0.750 kg (1.287 lb)

-10...+70 °C
-10...+60 °C
-25...+85 °C
2-17.8 Hz, amplitude ± 1.6 mm
17.8 Hz - 500 Hz, 2 g
2-800 Hz 0.5 s² (s³)
15 g (6 ms), 10 g (11 ms)

-25...+70 °C
-25...+60 °C
-40...+85 °C

300 V
300 V
50 V
50 V
50 V
6 kV 1.2/50 μs
4 kV 1.2/50 μs
500 V 1.2/50 μs
2.5 kV AC / 3.0 kV AC

50 V
50 V

1.5 kV 1.2/50 μs
0.8 kV 1.2/50 μs
500 V 1.2/50 μs
1.5 kV AC /
1.5 kV AC
1.5 kV AC /
1.5 kV AC

2.5 kV AC / 2.5 kV AC

output / PE 500 V AC / 500 V AC
2
input II (IEC/EN 60950-1), III (EN 50178)
output II (IEC/EN 60950-1), II (EN 50178)
2006/95/EC
2004/108/EC
2011/65/EC
IEC/EN 60950-1
SELV (IEC/EN 60950-1), PELV
IEC/EN 61000-6-2
IEC/EN 61000-4-2 Level 4 (8 kV / 15 kV)
IEC/EN 61000-4-3 Level 3 (10 V/m)
IEC/EN 61000-4-4 input circuit: Level 4 (4 kV)

IEC/EN 61000-4-5 input circuit: L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)
output circuit: Level 1 (0.5 kV)

conducted disturbances, induced by
radio-frequency fields
voltage dips, short interruptions and
voltag variations
Interference emission
high-frequency radiated
high-frequency conducted
limits for harmonic current emissions

typ. < 12.7 W
(24 V DC, 4.0 A)
typ. 90.5 %

0.5-4 mm² (20-12 AWG)
0.5-4 mm² (20-12 AWG)
0.5-6 mm² (20-10 AWG)
7 mm (0.28 in)
0.8 Nm (7.08 lb.in)

output circuit: Level 3 (2 kV)
surge

CP-ASI/4.0 DC/DC

IEC/EN 61000-4-6 Level 3 (10 V, 150 kHz - 80 MHz)
IEC/EN 61000-4-11 Class 3
IEC/EN 61000-6-3
IEC/CISPR 22, EN 55022 Class B
IEC/CISPR 22, EN 55022 Class B
IEC/EN 61000-3-2 Class A

input circuit:
Level 3 (2 kV)
output circuit:
Level 2 (1 kV)
input circuit: L-L Level 2
(1 kV) / L-PE Level 3 (2 kV)
output circuit:
Level 1 (0.5 kV)
Level 3 (10 V, 150
kHz - 80 MHz)

IEC/EN 61000-6-4

IEC/EN 61000-6-3

-

-

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/62

3

CP-ASI range
Technical diagrams
Characteristic curve at Ta = 25 °C

CP-ASI 2.8
Uout [V]

Iout [A]

32

2.8

24
20

8
4
0

0

1

2

3

Iout [A]

4

2CDC 272 007 F0012

12

-10

60

2CDC 272 006 F0212

2.1

16

70 Ta [°C]

Characteristic curve of temperature at rated load

Output behaviour

CP-ASI 4.0 DC/DC
Uout [V]

Iout [A]
35

4

30
25

3

20

5
0

0

1

2

3

4

5

6

8 Iout [A]

7

-25

60 70

2CDC 272 010 F0212

10

2CDC 272 011 F0012

15

Ta [°C]

Characteristic curve of temperature at rated load

Output behaviour

CP-ASI 4.0
Uout [V]
35

Iout [A]

30

4

20

3
2CDC 272 009 F0012

15
10
5
0

0

1

2

3

4

5

6

Iout [A]

2CDC 272 008 F0212

25

-10

Output behaviour

60

70 Ta [°C]

Characteristic curve of temperature at rated load

CP-ASI 8.0
Uout [V]

Iout [A]

35
30

8

25

15
10
5
0

0

2

4

6

Output behaviour

8

10

12

Iout [A]

2CDC 272 012 F0212

6

20
2CDC 272 013 F0012

3

28

-10

60

70

Ta [°C]

Characteristic curve of temperature at rated load

3/63 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-ASI range
Dimensional drawings
Dimensions in mm/inch
CP-ASI 2.8

CP-ASI 4.0 DC/DC

102 4.02”

102 4.02”
49 1.93”

94 3.78”

62 2.44”



40 1.58”



2CDC 272 016 F0012

62 2.44”

2CDC 272 014 F0012

62 2.44”
5 0.20”

3

131 5.16”

131 5.16”

62 2.44”

94 3.78”

5 0.20”

CP-ASI 4.0

CP-ASI 8.0

102 4.02”

102 4.02”

94 3.78”

94 3.78”

73 2.87”

91 3.58”

5 0.20”

131 5.16”

2CDC 272 017 F0012

62 2.44”
62 2.44”

2CDC 272 015 F0012

62 2.44”

131 5.16”

62 2.44”




5 0.20”

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/64

CP-B range
Product group picture

3

3/65 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-B range
Table of contents

CP-B
Product group picture

3/65

Table of contents

3/66

Benefits and advantages

3/67

Ordering details

3/68

Technical data

3/69

Technical data, Technical diagrams

3/70

Dimensional drawings

3/71

Technical data

3/72

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/66

3

CP-B range
Benefits and advantages
Power supply systems have to be highly reliable in most areas of
energy management and automation technology.
Often batteries are used for supporting the supply system in
case of mains failures. Batteries have limited lifetimes depending
on environmental parameters and have to be maintained regularly, which causes efforts and costs.

3

Characteristics
– – 3 buffer modules for buffering 24 V DC:
CP-B 24/3.0 (3 A / 1 kWs1))
CP-B 24/10.0 (10 A / 10 kWs1))
CP-B 24/20.0 (20 A / 8 kWs1))
– – CP-B 24/3.0 and CP-B 24/20.0 expandable
with additional extension module(s) CP-B EXT.2
(2 kWs1))
– – LEDs for status indication
– – Relay contacts for status messaging
– – Very high backup times (e.g. with CP-B 24/10.0
up to 8 minutes at 1 A load current)
– – Short charging times
– – High efficiency, higher than 90%
– – Wide temperature range
– – DIN rail mountable, compact housing

Using the latest ultra-capacitor technology, ABB offers an innovative and completely maintenance free new product for
buffering the 24 V DC supply in case of interrupted mains on the
primary side of the switch mode power supply.
The CP-B range is an ultra-capacitor buffer energy storage for
power supply units which ensures a short term uninterrupted
power supply system. In case of a power loss, the energy stored
in the capacitor guarantees that the load is continually provided
up to several hundred seconds depending on the load current.

Advantages in comparison to battery buffers:
– – Maintenance free
– – No deep discharge
– – Temperature resistant
– – A (UL508, CSA22.2 No 14), R approvals
1)

Order code
Rated input voltage
Rated current
Energy storage (min.)
Typical charging time
at load current
Typical
buffering time1)
at load current
1)

buffering time ≈

100
0
100
50
25
10

%
%
%
%
%
%

internal energy buffer

CP-B 24/3.0

CP-B 24/10.0

CP-B 24/20.0

CP-B EXT.2

1SVR427060R0300
24 V DC
3 A DC
1.000 Ws
65 s
56 s
13 s
28 s
66 s
148 s

1SVR427060R1000
24 V DC
10 A DC
10.000 Ws
134 s
82 s
38 s
76 s
140 s
380 s

1SVR427060R2000
24 V DC
20 A DC
8.000 Ws
135 s
62 s
15 s
30 s
60 s
150 s

1SVR427065R0000
–
3 A DC
2.000 Ws

energy storage x 0.9
current x output voltage

1 Input terminals
SHUT-DOWN+, SHUT-DOWN-: Input signal terminals
INPUT OK, BUFFER STATUS, FAILURE: Signalling contact – terminals
L+IN, L-IN: Input voltage terminals

2 Indication of operational states

1

OPERATION: Buffer module in operation (standby or buffering)
INPUT OK: Input voltage applied

3 Output terminals

2

1
3

3/67 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

L+OUT, L-OUT, L-OUT: Output voltage terminals

CP-B range
Ordering details

2CDC 271 001 S0010

Description

CP-B 24/3.0

Ultra capacitor based buffer units of the CP-B range offer highest reliability also in harsh
enivronment. Due to the ultra-cap based technology the units are maintenance free, there will
be no deep discharge and these products offer a very wide operational ambient temperature
range.
CP-B range buffer units are an excellent solution to avoid voltage drops, for example in solar
applications.

3
Ordering details
Rated input voltage

Rated current

Type

Order code

Price
1 pce

2CDC 271 002 S0010

24 V DC

CP-B 24/10.0

Weight
(1 pce)
kg (lb)

3 A DC

CP-B 24/3.0

1SVR427060R0300

0.55 (1.21)

10 A DC

CP-B 24/10.0

1SVR427060R1000

2.10 (4.63)

20 A DC

CP-B 24/20.0

1SVR427060R2000

2.20 (4.85)

Ordering details - Extension unit for CP-B 24/3.0 and CP-B 24/20.0
Rated voltage

Voltage range

Type

Order code

Price
1 pce

0-26.4 V DC

CP-B EXT.2

1SVR427065R0000

1.00 (2.20)

Example of application
L

N

L+

L-

CP-C 24/20.0

2CDC 271 003 S0010

24 V DC

Weight
(1 pce)
kg (lb)

CP-B 24/20.0

max. 20 A

L-IN

L+OUT

L-OUT

CP-B 24/10.0

L+IN

max. 10 A
L+

buffered

L+

L-

unbuffered

L-

load 1

...

load n

load 1

...

load n

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/68

CP-B range
Technical data
Type

3

CP-B 24/3.0

Input circuit - Supply circuit
Rated input voltage U in
Input voltage range
Minimum charging potential
Rated input current
Inrush current limiting
Transient overvoltage protection
Internal input fuse (apparatus protection, not accessible)
Internal fuse capacitors circuit (not accessible)
Kind of input

Output circuit
Rated output power
Rated output voltage Uout
Output voltage (buffer mode)
Tolerance of the output voltage
Rated output current Ir
Peak output current (fully loaded capacitors
required)
Control of limiting current
Shut-down if limiting current is exceeded
Short-circuit protection (only via external fuse)
Internal output fuse (not accessible)
Required external fuse
Current limiting at output circuit
Breaking capacity of output circuit
Power failure buffering time

1)

CP-B 24/10.0

CP-B 24/20.0

L+IN L-IN
24 V DC
23.7-26.4 V DC
23.7 V DC
3 A DC
50 A / 1 ms
suppressor diode
4 A slow acting
SHUT-DOWN rated voltage voltage range 69 W
24 V DC
23.0 V DC
+2...-10 %
Ta  60 °C 3 A DC

23.9-27 V DC
23.9 V DC
10 A DC
35 A / 2 ms
varistor / suppressor diode
15 A (FK2)
25 A (FK2)
control input
24 V DC
6-45 V DC
L+OUT L- OUT L- OUT
240 W

23.4-27.4 V DC
23.4 V DC
20 A DC
35 A / 2 ms
varistor / suppressor diode
30 A (FK2)

23.2 V DC

23.2 V DC

10 A DC

20 A DC

Ta  60 °C 6 A DC (min. 1.5 s)

20 A DC (10 A power supply
+ 10 A CP-B, min. 1.5 s)
10.3 A DC w0.1A
after 1.5 s
no continuous short-circuit stability
15 A (FK2)
3.15 A slow acting
10 A slow acting
1.05...1.2 x I r

t= 2.5 ms load-dependent, min.
13 s at 100 % load

Overload protection
Kind of output

control input
24 V DC
6-45 V DC
480 W

40 A DC (min. 1.5 s)
25 A slow acting
-

24 V DC, 10 A

-

load-dependent, min.
38 s at 100 % load

load-dependent, min.
15 s at 100 % load

thermal protection
INPUT OK n/o contact
BUFFER STATUS n/o contact
FAILURE c/o contact
Contact material
Ag + Au-clad
Minimum switching voltage / Minimum switching current
5 V DC / 1 mA
Maximum switching voltage / Maximum switching current
50 V AC / 1.0 A, 30 V DC / 0.5 A
Mechanical lifetime
5 x 10 6 switching cycles
Electrical lifetime
0.1 x 10 6 switching cycles
Maximum fuse rating to achieve short-circuit protection
n/o or n/c contact 1.0 A AC / 0.5 A DC
General data
Maximum internal power consumption
7W
20 W
40 W
Power consumption with unloaded output
0.75 W
3W
1.6 W
Energy storage (min.)
1000 Ws
10000 Ws
8000 Ws
100 % 65 s
134 s
135 s
Typical charging time at load current
0 % 56 s
82 s
62 s
100 % 13 s
38 s
15 s
Typical buffering time at load current1)
50 % 28 s
76 s
30 s
25 % 66 s
140 s
60 s
10 % 148 s
380 s
150 s
Efficiency
greater than 90 %
Dimensions (W x H x D)
product dimensions 60 x 99 x 120 mm
116 x 170 x 147 mm
84 x 197 x 213 mm
(2.36 x 3.90 x 4.72 in)
(4.57 x 6.69 x 5.79 in)
(3.31 x 7.76 x 8.39 in)
Weight
net weight 0.55 kg (1.21 lb)
2.1 kg (4.63 lb)
2.2 kg (4.85 lb)
Material
cover / housing shell steel sheet powdered
Mounting
DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position
horizontal
Minimum distance to other units
horizontal not necessary
vertical 40 mm (1.58 in)
80 mm (3.15 in)
Pollution degree
2
Degree of protection
housing / terminal IP20
Protection class (IEC/EN 61140)
III SELV / PELV (condition: power supply fulfills class III)
Electrical connection - Input circuit / Output circuit
pull spring terminals
pull spring terminals pluggable screw type terminals
Wire size
fine-strand with(out) wire end ferrule 0.08-1.0 mm ²
0.08-1.5 mm ²
0.2-4.0 mm ²
(28-18 AWG)
(28-18 AWG)
(24-12 AWG)
rigid 0.08-1.5 mm ²
0.08-4.0 mm ²
0.2-6.0 mm ²
(28-16 AWG)
(28-16 AWG)
(24-10 AWG)
Stripping length
6.0 mm (0.24 in)
7.0 mm (0.28 in)

3/69 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CP-B range
Technical data, Technical diagrams
Type

CP-B 24/3.0

Input circuit - Supply circuit
Signalling circuit
Wire size

CP-B 24/10.0

CP-B 24/20.0

L+IN L-IN
fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG)
rigid 0.08-1.5 mm² (28-16 AWG)
6.0 mm (0.24 in)

Stripping length
Environmental data
Ambient temperature

0.14-1.0 mm² (26-16 AWG)
0.14-1.5 mm² (28-16 AWG)
7.0 mm (0.28 in)

operation -40...+60 °C
storage -40...+60 °C

Standards
Product standard
Low Voltage Directive
EMC Directive
RoHS Directive
Electrical safety
Electromagnetic compatibility
Interference immunity to
electrostatic discharge
radiated, radio-frequency, electromagnetic field
electrical fast transient/burst
surge
conducted disturbances, induced by radiofrequency fields
voltage dips, short interruptions and voltage
variations
Interference emission
high-frequency radiated
high-frequency conducted

-20...+60 °C
-20...+60 °C

3

EN 50178
2006/95/EC
2004/108/EC
2011/65/EC
EN 50178, EN 60950, UL 508

IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6

IEC/EN 61000-6-1, IEC/EN 61000-6-2
Level 3, 6 kV / 8 kV
Level 3, 10 V/m (27-1000 MHz) / Level 2, 3 V/m (1400-2700 MHz)
Level 3, 2(1) kV / 5 kHz
Level 1, 0.5 kV
Level 3, 10 V (150 kHz-80 MHz)

IEC/EN 61000-4-11 buffered by ultra-capacitors
EN 61000-6-3, EN 61000-6-4
DIN EN 55011 B/C1
DIN EN 55011 B/C1

„Approvals and marks“ on page 3/4.
1)

energy storage x 0.9
load current x output voltage

buffering time ≈

Technical diagrams
Output curve at Ta = 25 °C
Normal application (up to
50 % buffer mode, 5 charging
and discharging cycles in
direct series)
Continuous charging and
discharging in direct series.
As this is not typical of a real
application, this should
be considered as theoretical
indication

1.5

Ta [°C]
0

20

40

60

10

CP-B 24/3.0

0

20

40

60

Continuous charging and
discharging in direct series.
As this is not typical of a real
application, this should
be considered as theoretical
indication

7.5
5.0

Ta [°C]
20

40

60

CP-B 24/10.0
Caracteristic curve of the temperature at rated load

60
50
40
30

2CDC 272 029 F0210

10.0

Years

Normal application (up to
50 % buffer mode, 5 charging
and discharging cycles in
direct series)

0

Ta [°C]
-20

CP-B 24/20.0

Iout [A]

-40

Continuous charging and
discharging in direct series.
As this is not typical of a real
application, this should
be considered as theoretical
indication

15

20
10
0

10

20

30

40

50

60

70

2CDC 272 031 F0210

-40

Normal application (up to
50 % buffer mode, 5 charging
and discharging cycles in
direct series)

20

2CDC 272 028 F0210

3.0

Iout [A]

2CDC 272 030 F0210

Iout [A]

Temperature [°C]

Capacitor's life span over temperature

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/70

CP-B range
Dimensional drawings

119 4.69‘‘
120 4.72‘‘

CP-B 24/3.0

193 7.60‘‘

197 7.76‘‘

188 7.40‘‘
84 3.31‘‘

196 7.72‘‘
213 8.39‘‘

2CDC 272 039 F0010

112 4.41‘‘

2CDC 272 037 F0010

99 3.90‘‘

60 2.36‘‘

CP-B 24/10.0

138 5.43‘‘
146 5.75‘‘
147 5.79‘‘

93 3.66‘‘

60 2.36‘‘

112 4.41‘‘
119 4.69‘‘
120 4.72‘‘

CP-B EXT.2

3/71 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

2CDC 272 036 F0010

116 4.57‘‘

2CDC 272 038 F0010

99 3.90‘‘

163 6.42‘‘

CP-B 24/20.0

170 6.69‘‘

3

93 3.66‘‘

Dimensions in mm and inches

CP-B range
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
Type

CP-B EXT 2.0

Extension circuit

EXT+ EXT+ EXT- EXT-

Rated voltage

24 V DC

Voltage range

0-26.4 V DC

Rated current

3 A DC

Internal input fuse (apparatus protection, not accessible)

4 A slow acting (PTC)

Short-circuit protection

via internal 3 A fuse

Overload protection

only in combination with CP-B 24/3.0 or CP-B 24/20.0

Indication of operational states
status information and fault messages of the buffer module
apply
General data
Power consumption without load

0.5 W

Energy storage (min.)

2000 Ws

Dimensions (W x H x D)

product dimensions 60 x 99 x 120 mm (2.36 x 3.90 x 4.72 in)
packaging dimensions 85 x 220 x 170 mm (3.35 x 8.66 x 6.69 in)

Weight

net weight 1.00 kg (0.20 lb)

Material

cover / housing shell steel sheet powdered

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal not necessary
vertical 40 mm (1.58 in)

Pollution degree

2

Degree of protection

housing / terminal IP20

Protection class (IEC/EN 61140)
Electrical connection - Extension circuit
Wire size

III SELV / PELV (condition: power supply fulfills class III)
fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG)
rigid 0.08-1.5 mm² (28-16 AWG)

Stripping length

6.0 mm (0.24 in)

Signalling circuit
Wire size

fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG)
rigid 0.08-1.5 mm² (28-16 AWG)

Stripping length
Environmental data
Ambient temperature
Vibration, sinusoidal
Shock, half-sine

6.0 mm (0.24 in)
operation -40...+60 °C
storage -40...+60 °C
based on IEC/EN 60068-2-6 1.5 mm, 3-57.55 Hz; 2 g, 57.55-500 Hz, 10 cycles
based on IEC/EN 60068-2-27 15 g, 11 ms, 3 axes, 6 faces, 3 times for each face

Standards
Product standard

EN 50178

Low Voltage Directive

2006/95/EC

EMC Directive

2004/108/EC

RoHS Directive

2011/65/EC

Electrical safety

EN 50178, EN 60950, UL 508

Electromagnetic compatibility
Interference immunity to
electrostatic discharge

IEC/EN 61000-6-1, IEC/EN 61000-6-2
IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 Level 3, 10 V/m (27-1000 MHz) / Level 2, 3 V/m (1400-2700 MHz)

electrical fast transient/burst

IEC/EN 61000-4-4 Level 3, 2(1) kV / 5 kHz

surge

IEC/EN 61000-4-5 Level 1, 0.5 kV

conducted disturbances, induced by radio-frequency
fields
voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-6 Level 3, 10 V (150 kHz-80 MHz)

Interference emission

IEC/EN 61000-4-11 buffered by ultra-capacitors
EN 61000-6-3, EN 61000-6-4

high-frequency radiated

DIN EN 55011 B/C1

high-frequency conducted

DIN EN 55011 B/C1

„Approvals and marks“ on page 3/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/72

3

Electronic protection devices EPD24
Product group picture

3

3/73 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Electronic protection devices EPD24
Table of contents

Electronic protection devices EPD24
Product group picture

3/73

Table of contents

3/74

Ordering details

3/75

Technical data

3/76

Technical information

3/78

Approvals, safety instructions

3/79

Installation guidelines

3/80

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/74

3

Electronic protection devices EPD24
Ordering details

2CDC 051 001 S0010

3

EPD24-TB-101-3A

The protection devices EPD24 extend the ABB product range of Modular DIN rail components by
electronic overcurrent protection modules for selective protection of 24 V DC load circuits.
This protection is achieved by a combination of active electronic current limitation in the case of a
short circuit and an overload deactivation from 1.1 x In upwards.
If a fault occurs in a load circuit, the protection device EPD24 will detect this rapidly and reliably,
disable the power output transistor and hence interrupt the current flow in the defective circuit. The
maximum possible overcurrent is always limited to 1.3…1.8 times the selected rated current. An
activation of capacitive loads up to 20,000 μF is possible, deactivation only occurring in the case of
overloads or short circuits. Selective deactivation of the defective current circuit means undefined
error states and a complete system stop are prevented.
Features
–– Selective load protection, one electronic tripping characteristic.
–– Active current limitation for safe connection of capacitive loads up to 20,000 µF and on
overload/short circuit.
–– Current ratings 0.5 A...12 A.
–– Reliable overload disconnection with 1.1 x IN
–– Manual ON/OFF button
–– Clear status and failure indication through LED and integrated auxiliary contact.
–– Integral fail-safe element adjusted to current rating.
–– Width per unit only 12.5 mm.
–– Rail mounting
–– Ease of wiring through busbar LINE+ and 0 V as well as signal bars.
–– UL- and CSA-approvals allow international use of the devices.
Ordering details
Ratedcurrent IN

bbn 40 16779 EAN

Type

Order code

Price

0.5

829960

EPD24-TB-101-0.5A

2CDE601101R2905

4

1

829984

EPD24-TB-101-1A

2CDE601101R2001

4

2

830003

EPD24-TB-101-2A

2CDE601101R2002

4

3

830027

EPD24-TB-101-3A

2CDE601101R2003

4

4

830041

EPD24-TB-101-4A

2CDE601101R2004

4

6

830065

EPD24-TB-101-6A

2CDE601101R2006

4

8

830089

EPD24-TB-101-8A

2CDE601101R2008

4

10

830102

EPD24-TB-101-10A

2CDE601101R2010

4

12

830126

EPD24-TB-101-12A

2CDE601101R2012

4

A

Pkg
qty

Weight
(1 pce)
kg (lb)
0.065
(1.433)
0.065
(1.433)
0.065
(1.433)
0.065
(1.433)
0.065
(1.433)
0.065
(1.433)
0.065
(1.433)
0.065
(1.433)
0.065
(1.433)

Ordering details
Description

bbn 40
Type
16779 EAN

Busbars for LINE+ and 0 V,
830140
grey insulation, length 500 mm 1)
Signal Bars for aux. contacts, grey
830164
insulation, length 21 mm
1)

Price

Pkg
qty

EPD-BB500

2CDE605100R0500

10

EPD-SB21

2CDE605200R0021

10

 ax. load with one line entry Imax = 50 A (recommended: mid line entry)
M
Max. load with two line entries Imax = 63 A

3/75 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Order code

Weight
(1 pce)
kg (lb)
0.2
(0.441)
0.4
(0.882)

her Sicherungsautomat ESX10-T
- und Sicherheitshinweise

Electronic protection devices EPD24
Technical data
Signaleingänge/-ausgänge (Anschlussdiagramme)

Wiring diagramm
sgänge (Anschlussdiagramme)
EPD24-TB-101 gezeigt
us- oder Fehlerzustand

K

without signal input
with signal output F
(Single signal, N/O)

ESX10-TB-101
Operating condition: 13-14 closed
Ohne
FaultSignaleingang
condition: 13-14 open
Mit Meldeausgang F
(Einzelsignal, Schließer)
LINE+

24 V DC (18...32 V)

Current rating I N

fixed current ratings: 0.5, 1, 2, 3, 4, 6, 8, 10, 12 A

Closed current I 0

ON condition: typically 20...30 mA depending on signal output

Staus indication by means of

Green:
unit is ON
load circuit / Power-MOSFET is switched on
Orange:
in the event of overload or short circuit until electronic
disconnection
Red:
unit electronically disconnected
load circuit/Power-MOSFET OFF
undervoltage (U B < 8 V)
after switch-on till the end of the delay period
OFF:
manually switched off or device is dead
potential-free auxiliary contact F
ON/OFF/ condition of switch

ESX10-TB-102
Ohne Signaleingang
Mit Meldeausgang F
(Einzelsignal, Öffner)

1

1

LINE+

12

14

Load circuit
11
Load output
Overload disconnection
Short-circuit current I K
Trip time

13

2

Operating data
Operating voltage U B

LOAD+

2

Power-MOSFET switching output (high slide switch)
typically 1.1 x I N (1.05...1.35 x I N)
active current limitation
see time/current characteristics

LOAD+

For electronic disconnection

Temperature disconnection
Low voltage monitoring load output
0V

3

Normalzustand: 13-14 geschlossen
Fehlerzustand: 13-14 geöffnet

ESX10-TB-124
Mit Reseteingang RE
(+DC 24 V ↓)
Mit Statusausgang SF
(+24 V = Lastausgang EIN)
LINE+

1

Starting delay t Start
3
0V
Disconnection of
load circuit
Normalzustand: 11-12 geöffnet
Free-wheeling circuit

Fehlerzustand:

SF 23

RE 22

RE 22

2

LOAD+

0V

3

Normalzustand: SF +24 V = OK
Fehlerzustand: SF 0 V

5

suitable external free-wheeling circuit to be used with inductive

11-12 geschlossenload

Several load outputs must not be connected in parallel
Signal output
Electrical data
potential-free auxiliary contact
max. 30 V DC/0.5 A, min. 10 V DC/10 mA
ON condition LED green
voltage U B applied, switch is in ON position
no overload, no short circuit
ESX10-TB-127
OFF
LED offRE
device switched off (switch is in OFF position)
Mitcondition
Reseteingang
no voltage U B applied
(+DC 24 V ↓)
Fault
condition
LED
orange
overload condition > 1.1 x I N up to electronic disconnection
Mit Statusausgang SF invertiert
Fault
LED red EIN)
electronic disconnection upon overload or short circuit
(0 Vcondition
= Lastausgang
Device switched off with control signal (switch is in ON position)
Aux. contact
single signal, make contact
1
LINE+
contact open, terminal 13-14
Fault
signal output fault conditions
no operating voltage U B
ON/OFF switch is in OFF position
red LED lighted (electronic disconnection)

SF 23

2

typically 3 s at I Load > 1.1 x I N
typically 100 ms...3 s at I Load > 1.8 x I N
(or 1.5 x I N /1.3 x I N, )
internal temperature monitoring with electronic disconnection
with hysteresis, no reset required:
load »OFF« at U B< 8 V
typically 0.5 sec after every switch-on and after applying U B
electronic disconnection

LOAD+

0V

3

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/76

Normalzustand: SF 0 V = OK
Fehlerzustand: SF +24 V

3

Electronic protection devices EPD24
Technical data
General data

Dimensions (B x H x T)

backup fuse for EPD24 not required because of the integral
redundant fail-safe element
moulded
symmetrical rail to EN 50022-35x7.5
0...+50 °C (without condensation, see EN 60204-1)
-20...+70 °C
96 hrs/95 % RH/40 °C to IEC 60068-2-78, test Cab. climate class
3K3 to EN 60721
3 g, test to IEC 60068-2-6 test Fc
housing: IP20 DIN 40050
terminals: IP20 DIN 40050
emission: EN 61000-6-3
susceptibility: EN 61000-6-2
0.5 kV/pollution degree 2
reinforced insulation in operating area
max. 32 V DC (load circuit)
n/a, only electronic disconnection
UL 2367 Solid State Overcurrent Protectors
UL 1604, (class I, division 2, groups A, B, C, D)
UL 508
CSA C22.2 No. 213 (class I, division 2)
CSA C22.2 No. 142
CE logo
12.5 x 80 x 83 mm

Weight

approx. 65 g

Terminals

Line+/LOAD+/0V

Screw terminals

M4

Max. cable cross section flexible with wire end ferrule w/wo plastic sleeve

0.5 – 10 mm 2

Multi-lead connection (2 identical cables) rigid/flexible

0.5 – 4 mm 2

Flexible with wire end ferrule without plastic sleeve

0.5 – 2.5 mm 2

Flexible with TWIN wire end ferrule with plastic sleeve

0.5 – 6 mm 2

Wire stripping length

10 mm

Tightening torque (EN 60934)

1.5 – 1.8 Nm

Terminals

aux. contacts

Screw terminals

M3

Max. cable cross section flexible
with wire end ferrule w/wo plastic sleeve

0.25 - 2.5 mm 2

Wire stripping length

8 mm

Tightening torque (EN 60934)

0.5 Nm

Fail-Safe element
Housing material
Mounting
Ambient temperature
Storage temperature
Humidity

3

Vibration
Degree of protection
EMC
(EMC directive, CE logo)
Isolations coordination
(IEC 60934)
Dielectric strength
Isolation resistance (OFF condition)

Approvals/Declarations of conformity

Table 1: voltage drop, current limitation, max. load current
current rating
IN

typically voltage drop
UON at IN

active current
limitation (typically)

max. load current at 100 % ON duty
Tambient = 40 °C
Tambient = 40 °C

0.5 A
1A
2A
3A
4A
6A
8A
10 A
12 A

70 mV
80 mV
130 mV
80 mV
100 mV
130 mV
120 mV
150 mV
180 mV

1.8
1.8
1.8
1.8
1.8
1.8
1.5
1.5
1.3

0.5 A
1A
2A
3A
4A
6A
8A
10 A
12 A

x
x
x
x
x
x
x
x
x

IN
IN
IN
IN
IN
IN
IN
IN
IN

0.5 A
1A
2A
3A
4A
5A
7A
9A
10.8 A

Attention: when mounted side-by-side without convection the ERD24 should not carry more than 80 % of its rated load with 100 % ON duty due
to thermal effects.

3/77 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Electronic protection devices EPD24
Technical information
Time/Current characteristic curve (Tambient = 25 °C)
The trip time is typically 3 s in the range between 1.1 and 1.8 x IN1).
Electronic current limitation occurs at typically 1.8 x IN1) which means that under all overload conditions (independent of the power supply and the resistance of the load circuit) the max. overload before disconnection will not exceed 1.8 x IN1) times the current rating. Trip
time is between 100 ms and 3 sec (depending on overload or at short circuit).
Without this current limitation a considerably higher overload current would flow in the event of an overload or short circuit.
disconnection
typically 1.1 x IN 1.8 x IN1)

3

10000
1000

trip time in seconds

100

current limitation 1)
typically 1.8 x IN

10
5
1
0. 1
0.01
0

1

2

4

3

1)

5 IK

...times rated current

 urrent limitation typically 1.8 x IN at IN = 0.5 A...6 A
C
Current limitation typically 1.5 x IN at IN = 8 A or 10 A
Current limitation typically 1.3 x IN at IN = 12 A

Maximum cable lenghts
EPD24 reliably trips from 0 Ω up to max. circuit resistance R max.
Calculation of Rmax
Selected rating I N (A)

3

6

19.2

19.2

Trip current I ab = 1.25 x I N (A) (EPD24 trips after 3 s)

3.75

7.50

Rmax (Ω) = (UB/Iab) -0.050

5.07

2.51

Operating voltage U S (V DC) (= 80 % of 24 V)

2)

2)

Voltage drop of EPD24 and tolerance of trip point (typically 1.1 x I N = 1.05 ... 1.35 x I N) have been taken into account

Selection table for the incoming cable lengths with different cable cross-sections
Cable cross section A (mm 2)
Cable length L (m) (= single length)
5
10
15
20
25
30
35
40
45
50
75
100
125
150
175
200
225
250
Resistivity of copper ρ0 = 0.0178 (Ω x mm2)/m
Example 1: max. length for 1.5 mm2 and 3 A: 214 m
Example 2: max. length for 1.5 mm2 and 6 A: 106 m
3)

0.14
0.25
0.34
cable resistance (Ω) = (ρ0 x 2 x L) / A
1.27
0.71
0.52
2.54
1.42
1.05
3.81
2.14
1.57
5.09
2.85
2.09
6.36
3.56
2.62
7.63
4.27
3.14
8.90
4.98
3.66
10.17
5.70
4.19
11.44
6.41
4.71
12.71
7.12
5.24
19.07
10.68
7.85
25.34
14.24
10.47
31.79
17.80
13.09
38.14
21.36
15.71
44.50
24.92
18.32
50.86
28.48
20.94
57.21
32.04
23.56
63.57
35.60
26.18

0.5

0.75

1.00

1.50

0.36
0.71
1.07
1.42
1.78
2.14
2.49
2.85
3.20
3.56
5.34
7.12
8.90
10.68
12.46
14.24
16.02
17.80

0.24
0.47
0.71
0.95
1.19
1.42
1.66
1.90
2.14
2.37
3.56
4.75
5.93
7.12
8.31
9.49
10.68
11.87

0.18
0.36
0.53
0.71
0.89
1.07
1.25
1.42
1.60
1.78
2.67
3.56
4.45
5.34
6.23
7.12
8.01
8.90

0.12
0.24
0.36
0.47
0.59
0.71
0.83
0.95
1.07
1.19
1.78
2.37
2.97
3.56
4.15
4.75
5.34
5.93

3)

Example 3: mixed wiring: (Control cabinet --- sensor/actuator level)
R1 = 40 m for 1.5 mm2 and R2 = 5 m for 0.25 mm2:
R1 = 0.95 Ω, R2 = 0.71 Ω, total (R1 + R2) = 1.66 Ω

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/78

Electronic protection devices EPD24
Approvals, Safety instructions
Please note
The user must ensure that the cable cross sections of the relevant load circuit are suitable for the current rating of the EPD24
used. Automatic start-up of machinery after shut down must be prevented (Machinery Directive 98/37/EG and EN 60204-1).
In the event of a short circuit or overload the load circuit will be disconnected electronically by the EPD24.

3
Information on UL approvals/CSA approvals
UL1604
UL File # E 339238
CSA C22.2 No. 213 (Class I, Division 2)
CSA File # 2305929

Operating Temperature Code T5
–– This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only
WARNING:
–– Exposure to some chemicals may degrade the sealing properties of materials used in the following device: relay
Sealant Material:
–– Generic Name: Modified diglycidyl ether of bisphenol A
–– Supplier: Fine Polymers Corporation
–– Type: Epi Fine 4616L-160PK
–– Casing Material:
–– Generic Name: Liquid Crystal Polymer
–– Supplier: Sumitomo Chemical
–– Type: E4008, E4009, or E6008
RECOMMENDATION:
–– Periodically inspect the device named above for any degradation of properties and replace if degradation is found
WARNING – EXPLOSION HAZARD:
–– Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous
–– Substitution of any components may impair suitability for Class I, Division 2
UL2367
Non-hazardous use - UL File # E 339236
UL 508
Non-hazardous use - UL File # E 149922
CSA C22.2 No. 14
CSA C22.2 No. 142 - CSA File # E 2305929
Class 2
Meets requirement for Class 2 current limitation (EPD24 ... -0,5 A/1 A/2 A/3 A)

3/79 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Electronic protection devices EPD24
Installation guidelines

The EPD24 features an integral power distribution system.
The following wiring modes are possible with various pluggable current and signal busbars:
–– LINE+ (24 V DC)
–– 0 V
Caution: The electronic devices EPD24 require a 0 V connection
–– Auxiliary contacts

LINE+ busbar
2CDE605100R0500

continuous busbar
500 mm length, cut

3

(12.5 x n)-3 = length of busbars ± 0.5
e. g. (12.5 x 5)-3 = 59.5 ± 0.5

signal bar
2CDE605200R0021

remove protection against
brush contact from bottom side

insert protection against
brush contact

0 V busbar
2CDE605100R0500

12.5 x n = width of protector block
e. g. 12.5 x 5 = 62.5

insert busbars
and protection slides
to be flush with housing sides

insert signal
bars to be flush with
housing and place them
centrally over the contacts

Mounting procedure
Before wiring insert busbars into protector block. A maximum of 10 connection cycles are permissible using connecting busbars.
Recommendation
After 10 units the busbars should be interrupted and receive a new entry live.
Table of length for busbars
(Order code 2CDE605100R0500)
No. of units
Length of busbar (mm) ± 0.5 mm

2
22

3
34.5

4
47

5
59.5

6
72

7
84.5

8
97

9
109.5

10
122

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/80

Analog signal converters, Serial data converters
Product group picture

4

4/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Analog signal converters, Serial data converters
Table of contents
Analog signal converters, serial data converters
Overview

4/3

Analog signal converters - CC-E range............................................... 4/5
Table of contents

4/6

Benefits and advantages

4/7

Ordering details - Standard signal converters

4/8

Ordering details - RTD converters

4/9

Ordering details - Thermocouple converters

4/10

Ordering details - Measuring converters

4/11

DIP switch settings, Dimensional drawings

4/12

Wiring instructions

4/13

Technical data

4/14

Analog signal converters - CC-U range............................................. 4/17
Table of contents

4/18

Overview

4/19

Ordering details

4/21

Ordering details - Accessories

4/22

DIP switch settings

4/23

Wiring instructions

4/25

Technical information

4/26

Technical data

4/29

Technical diagr., Connection diagr., Dimensional drawings

4/32

Serial data converters...................................................................... 4/33
Table of contents

4/34

Benefits and advantages

4/35

Selection table

4/36

Ordering details

4/37

Technical information

4/38

Technical data

4/46

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/2

4

Analog signal converters, Serial data converters
Overview
Applications for analog signal processing and correct
solution using CC-E and CC-U converters
0-10 V

Controller
e.g. AC500
1.
Analog signal converter
(e.g. CC-E or CC-U)

100 m

2.
Analog signal converter
(e.g. CC-E or CC-U)

0-20 mA

100 m

4-20 mA
Actuator

Signal conversion
Sometimes the available signals cannot be processed by the
controller or the actuator. In this case, signal converters are
required to convert the input signal (or different input signals)
to the desired output signal.

Signal filtering
Particularly on long lines or in rough industrial environments
the signals are exposed to high electromagnetic interferences. The frequency of the coupled interference signals may be
in the range of the common mains frequency (50 Hz) or even
much higher (in case of frequency converters). According to
the specific requirements, analog signal converters are available which provide reliable suppression of those interferences
by means of an input low-pass filter.

Measuring sensor

2CDC 282 013 F0206

Signal amplification
If long lines or high burdens have to be operated, it may be
necessary to amplify the signal. CC analog signal converters
require only low input power and provide high output power.
Thus, there are no restrictions for the converter's position on
the line, i.e. it can be used
– – for signal refreshing (1) at the end of the line (low input
power)
– – or for signal amplification (2) at the beginning of the line
(high output power).

Signal separation
– – Protection against overvoltage
The increased use of micro-electronics make controls
much more sensitive against overvoltages, resulting from
lightning discharges or switching processes. Suppression
diodes are incorporated in the input of the CC analog
signal converters which enable the converters to arrest
overvoltages with low energy level (resulting from switching processes) by themselves. The products furthermore
provide electrical isolation between input, output and
supply circuit for protection of the controller connected to
the output.
– – Protection against ground loops
If components are used which refer to ground, the measuring signals can be falsified by a so-called ground loop.
In this case, certain parts of the signal are transmitted
via earth and not via the analog transmission line, thus
causing incorrect evaluation of the signal. The electrical
isolation between the input and the output disconnects
these ground loops and thus enables correct signal
transmission.

K
E

J

J

CC-U/V

J

CC-U/I

J
G

CC-E I AC/ILPO

J

J

CC-E/I

J

CC-U/TCR

J
G

CC-U/TC

J

J

CC-E/TC

J

CC-U/RTDR

J

CC-U/RTD

CC-U/STDR

J
508, CAN/CSA C22.2 No.14
UL 1604 (Class I, Div 2, hazardous locations),
G
CAN/CSA C22.2 No.213
CB scheme
CCC

CC-E/RTD

A

CC-U/STD

Approvals
A UL

CC-E I/I

J existing
G existing for some devices
j pending

CC-E/STD

4

Nearly every process includes a control system that receives
data by means of analog signals and then evaluates the data
and sets the respective parameters correspondingly.
When transmitting analog signals numerous problems may
arise which can disturb or even block an ideal behavior of the
process.
Below we have listed some processing problems together
with the respective solutions to solve these problems:

0-10 V

J

J

J

J

G

J

J

J

J

J

J

J

J

Marks
a

CE

J

J

J

J

J

J

J

J

J

J

J

J

J

J

b

C-Tick

J

J

J

J

J

J

J

J

J

J

J

J

J

J

4/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Analog signal converters, Serial data converters
Overview
In the field of industrial data transmission, various processes of data transmission and interfaces are used today. Already existing systems need to be updated
or connected to new devices for continuity of process. When new communication functions are not build-in, ABB propose a range of converters to be able to
use from the standard RS232 or RS485, to the Ethernet open products or the Optical Fiber.
Ethernet communication is now one of the main features need in open communication, ABB propose the e-ILPH to connect the serial devices to the web
world.

Uses

Example :

Adaptation
The use of converters allows the connection of two devices using different interfaces. To add new equipment to existing installations.
Electrical Isolation
To protect sensitive equipment it is sometimes necessary to use converters which allow electrical isolation.

RS-485

RS-232

4

Example :
Line 1
Line 2
Power

To cross a disturbed environment
Some interfaces are more sensitive to noise. Electrically, it is preferable,
in some cases, to change the interface or support.
Type of connection
RS232
RS422
RS485
CL
OF
Ethernet

Immunity to noise
Low
High
High
High
Very high
High

Type of connection
RS232
RS422
RS485
CL
OF
Ethernet

1)

Noisy
elements
RS-232
RS-422

RS-422

Example :
RS-485 2-/4 wires

RS-232

RS-232

Connection
Point to point
12 points
32 points
5-6 points
32 points
Point to point or multipoint

RS-232 RS-232 RS-232 RS-232

Increase in the transmission and amplification distances of the
signals
Every connection has its own limits, to increase the communication distances you only have to change the type of link (converter) or amplify the
signal (Repeater) using an ILPH.
Type of connection
RS232
RS422
RS485
CL
OF
Ethernet

Example :

RS-232

Multipoint connections
Some equipments are only designed to communicate in RS232 point to
point connection. To communicate with several devices it is then necessary to use converters RS232 to RS422, RS485, CL or OF to reach
multipoint mode.

RS-485

Example :

RS-232

Max. distances 1)
15 m
1.2km
1.2km
300-500m
4 km
100 m with CAT5 cable

Depending on transmission speed

Converter

15 m
max.

Repeater

RS-422

RS-422

1.2 km
max.

1.2 km
max.

15 m
max.

RS-232

Example :

"World Wide" communication
Communication is more and more used with Ethernet support. The
interests are to have a distant access, to use an already existing network
and to upload information and data on a supervisor or a computer. The
conversions from serial to Ethernet protocol are used to connect local
network to Ethernet.
Protocol conversion
Modbus is one of the main protocols used in the industrial networks.
The creation of Modbus/TCP allows an adapted access to the Ethernet
network. So, the conversion between these 2 protocols is necessary.

TCP

RS-232
RS-485

Example :
Modbus /
TCP

Modbus /
RTU

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/4

Analog signal converters - CC-E range
Product group picture

4

4/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Analog signal converters - CC-E range
Table of contents
Analog signal converters - CC-E range
Benefits and advantages

4/7

Ordering details - Standard signal converters

4/8

Ordering details - RTD converters

4/9

Ordering details - Thermocouple converters

4/10

Ordering details - Measuring converters

4/11

DIP switch settings, Dimensional drawings

4/12

Wiring instructions

4/13

Technical data

4/14

Technical data

4/15

Technical data

4/16

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/6

4

Analog signal converters - CC-E range
Benefits and advantages
1

1 Terminals M, K, J, H, G
2 Terminal explanation
3 Adjustment of gain

2

4 Adjustment of offset
4 Indication of operational states

U - control supply voltage applied

3

4

4
5

CC-E range
– – Universally configurable devices and single-function devices
– – Adjustment and operating elements on the front side
– – Safe operation by electrical 3-way isolation
– – Unambiguous and clear connecting terminal markings

2

1

Conversion, measurement and separation of
– – Standard signals (0-5 V, 0-10 V, 0-20 mA, 4-20 mA)
– – Temperature signals of RTD sensors (PT 100)
– – Thermocouple signals (types J and K)
– – Current measurement signals (0-5 A, 0-20 A AC/DC)
Characteristics of single-function devices
– – No adjustment or balancing necessary.
Characteristics of universal devices
– – The required input and output ranges can be configured by
means of directly accessible DIP switches positioned on
the side
– – Gain adjustment of ±5 % by means of an adjustment potentiometer on the front-side
– – Offset adjustment of ±5 % by means of adjustment potentiometers on the front-side

CC-E/STD analog signal converter with 3-way electrical
isolation
–– 2 universally configurable devices (type CC-E/STD)
–– 2x10 single-function devices
–– "Plug and Work", no adjustment of single-function devices
required

CC-E/RTD temperature signal converter for RTD sensors,
linearized with 3-way electrical isolation
– – 2 universally configurable devices (type CC-E/RTD)
– – 2x12 single-function devices
– – Plug and Work", no adjustment of single-function devices
required
– – Temperature signal converter for PT100 sensors
– – 2- or 3-wire connection

CC-E/TC analog signal converter for thermocouple signals
of the types J and K with 3-way electrical isolation
–– 2 universally configurable devices (type CC-E/TC)
–– 2x6 single-function devices
–– "Plug and Work", no adjustment of single-function devices
required
–– Integrated cold-junction compensation

CC-E/I measuring converter for current signals 0-5 A, 0-20
A, AC/DC with 3-way electrical isolation
– – 2 universally configurable devices (type CC-E/I)
– – 2x6 single-function devices
– – "Plug and Work", no adjustment of single-function devices
required

CC-E IAC/ILPO measuring converter without auxiliary
power for sinusoidal currents 0-1 A, 0-5 A, output 4-20
mA
–– Measuring converter for sinusoidal currents (0-1 A, 0-5 A)
–– Measuring range selection by front-face sliding switch
–– 4-20 mA output current in proportion to input current
–– no additional power supply required

Loop-powered current/current isolator without external
power supply for analog current signals of 0-20 mA and
4-20 mA
– – Electrical isolation between input and output
– – Very low internal voltage drop  2.5 V
– – Available with one or two independent channels
– – Width only 18 mm (1 and 2 channels)

4/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Analog signal converters - CC-E range
Ordering details - Standard signal converters
Ordering details - Standard signal converters
Supply
voltage range

Input signal

2CDC 281 010 F0003

CC-E/STD1)

1SVR011700R0000

0-10 V

CC-E V/V

1SVR011710R2100

0-20 mA

CC-E V/I

1SVR011711R1600

4-20 mA

CC-E V/I

1SVR011712R1700

0-10 V

CC-E I/V

1SVR011713R1000

0-20 mA

CC-E I/I

1SVR011714R1100

4-20 mA

CC-E I/I

1SVR011715R1200

0-10 V

CC-E I/V

1SVR011716R1300

0-20 mA

CC-E I/I

1SVR011717R1400

4-20 mA

CC-E I/I

1SVR011718R2500

-10...+10 V

-10...+10 V

CC-E V/V

1SVR011719R2600

0-5 V, 0-10 V,
0-20 mA,
4-20 mA

0-5 V, 0-10 V,
0-20 mA, 4-20 mA

CC-E/STD

1SVR011705R2100

0-10 V

CC-E V/V

1SVR011720R2300

0-20 mA

CC-E V/I

1SVR011721R1000

4-20 mA

CC-E V/I

1SVR011722R1100

0-10 V

CC-E V/V

1SVR011723R1200

0-20 mA

CC-E I/I

1SVR011724R1300

4-20 mA

CC-E I/I

1SVR011725R1400

0-10 V

CC-E V/V

1SVR011726R1500

0-20 mA

CC-E I/I

1SVR011727R1600

4-20 mA

CC-E I/I

1SVR011728R2700

-10...+10 V

-10...+10 V

CC-E V/V

1SVR011729R2000

0-20 mA,
4-20 mA

CC-E I/I-12)

1SVR010200R1600

0-20 mA, 4-20 mA
CC-E I/I-22)

1SVR010201R0300

2CDC 281 001 F0003

0-20 mA

4-20 mA

CC-E V/V

0-10 V
2CDC 281 041 F0003

Order code

0-5 V, 0-10 V,
0-20 mA, 4-20 mA

0-10 V

24 V DC

Type

110-240 V AC
0-20 mA

CC-E I/I-2

4-20 mA

loop powered

1)
2)

Price
1 pce

0-5 V, 0-10 V,
0-20 mA,
4-20 mA

CC-E/I

Output signal

Weight
(1 pce)
kg (lb)
0.088
(0.194)
0.083
(0.183)
0.084
(0.185)
0.084
(0.187)
0.082
(0.181)
0.084
(0.187)
0.084
(0.185)
0.084
(0.185)
0.084
(0.187)
0.082
(0.181)
0.090
(0.198)
0.096
(0.212)
0.087
(0.192)
0.091
(0.200)
0.091
(0.200)
0.088
(0.194)
0.096
(0.212)
0.087
(0.192)
0.088
(0.194)
0.086
(0.190)
0.038
(0.084)
0.044
(0.097)

B 1604 Class I, Div.2 (universal device)
CC-E-I/I-1 has 1 channel, CC-E-I/I-2 has 2 channels

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/8

4

Analog signal converters - CC-E range
Ordering details - RTD converters
Ordering details - RTD converters
Supply
voltage range

Input signal

2CDC 281 004 F0003

Type

Order code

Price
1 pce

refer to table

PT100
0...100 °C

CC-E/RTD

4
PT100
-50...+50 °C
24 V DC

PT100
0...300 °C

PT100
-50...+250 °C

refer to table

PT100
0...100 °C

PT100
-50...+50 °C
110-240 V AC

PT100
0...300 °C

PT100
-50...+250 °C

1)

Output signal

Weight
(1 pce)
kg (lb)

0-10 V, 0-20 mA,
4-20 mA

CC-E/RTD1)

1SVR011701R2500

0.091
(0.200)

0-10 V

CC-E RTD/V

1SVR011730R2500

0.084
(0.185)

0-20 mA

CC-E RTD/I

1SVR011731R1200

4-20 mA

CC-E RTD/I

1SVR011732R1300

0-10 V

CC-E RTD/V

1SVR011733R1400

0.083
(0.183)

0-20 mA

CC-E RTD/I

1SVR011734R1500

0.084
(0.185)

4-20 mA

CC-E RTD/I

1SVR011735R1600

0.084
(0.187)

0-10 V

CC-E RTD/V

1SVR011736R1700

0.084
(0.185)

0-20 mA

CC-E RTD/I

1SVR011737R1000

0.084
(0.187)

4-20 mA

CC-E RTD/I

1SVR011738R2100

0.101

0-10 V

CC-E RTD/V

1SVR011739R2200

0.084
(0.185)

0-20 mA

CC-E RTD/I

1SVR011740R0700

4-20 mA

CC-E RTD/I

1SVR011741R2400

0-10 V, 0-20 mA,
4-20 mA

CC-E/RTD

1SVR011706R2200

0.093
(0.205)

0-10 V

CC-E RTD/V

1SVR011788R2400

0.086
(0.190)

0-20 mA

CC-E RTD/I

1SVR011789R2500

0.088
(0.194)

4-20 mA

CC-E RTD/I

1SVR011790R2200

0.089
(0.196)

0-10 V

CC-E RTD/V

1SVR011791R1700

0.087
(0.192)

0-20 mA

CC-E RTD/I

1SVR011792R1000

4-20 mA

CC-E RTD/I

1SVR011793R1100

0-10 V

CC-E RTD/V

1SVR011794R1200

0-20 mA

CC-E RTD/I

1SVR011795R1300

4-20 mA

CC-E RTD/I

1SVR011796R1400

0-10 V

CC-E RTD/V

1SVR011797R1500

0.086
(0.190)

0-20 mA

CC-E RTD/I

1SVR011798R2600

0.089
(0.196)

4-20 mA

CC-E RTD/I

1SVR011799R2700

0.088
(0.194)

B 1604 Class I, Div.2 (universal device)

4/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

0.086
(0.190)

0.084
(0.187)

0.089
(0.196)
0.087
(0.192)
0.089
(0.196)

Analog signal converters - CC-E range
Ordering details - Thermocouple converters
Ordering details - Thermocouple Converters
Supply
voltage range

type J
0...600 °C
24 V DC

type K
0...1000 °C

thermocouple
types J and K

type J
0...600 °C
110-240 V AC

type K
0...1000 °C

1)

Output signal

Type

Order code

Price
1 pce

thermocouple
types J and K

2CDC 281 007 F0003

CC-E TC

Input signal

Weight
(1 pce)
kg (lb)

0-10 V, 0-20 mA,
4-20 mA

CC-E/TC1)

1SVR011702R2600

0.089
(0.196)

0-10 V

CC-E TC/V

1SVR011750R0100

0.087
(0.192)

0-20 mA

CC-E TC/I

1SVR011751R2600

0.084
(0.187)

4-20 mA

CC-E TC/I

1SVR011752R2700

0.102

0-10 V

CC-E TC/V

1SVR011753R2000

0-20 mA

CC-E TC/I

1SVR011754R2100

4-20 mA

CC-E TC/I

1SVR011755R2200

0.086
(0.190)

0-10 V, 0-20 mA,
4-20 mA

CC-E/TC

1SVR011707R2300

0.088
(0.194)

0-10 V

CC-E TC/V

1SVR011760R0300

0.084
(0.187)

0-20 mA

CC-E TC/I

1SVR011761R2000

0.088
(0.194)

4-20 mA

CC-E TC/I

1SVR011762R2100

0.1
(0.220)

0-10 V

CC-E TC/V

1SVR011763R2200

0.086
(0.190)

0-20 mA

CC-E TC/I

1SVR011764R2300

0.088
(0.194)

4-20 mA

CC-E TC/I

1SVR011765R2400

0.086
(0.190)

0.084
(0.185)

B 1604 Class I, Div.2 (universal device)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/10

4

Analog signal converters - CC-E range
Ordering details - Measuring converters
Ordering details - Measuring Converters
Supply
voltage range

0-5 A, 0-20 A,
AC
24 V DC

4

0-5 A, 0-20 A,
DC

0-5 A, 0-20 A,
AC/DC

110-240 V AC

0-5 A, 0-20 A,
AC

0-5 A, 0-20 A,
DC
loop powered
1)
2)

Output signal

Type

Order code

Price
1 pce

0-5 A, 0-20 A,
AC/DC

2CDC 281 018 F0004

CC-E IAC/ILPO

Input signal

0-1 A, 0-5 A, AC

Weight
(1 pce)
kg (lb)

0-10 V, 0-20 mA,
4-20 mA

CC-E/I1)

1SVR011703R2700

0.096
(0.212)

0-10 V

CC-E IAC/V

1SVR011770R0500

0.090
(0.198)

0-20 mA

CC-E IAC/I

1SVR011771R2200

4-20 mA

CC-E IAC/I

1SVR011772R2300

0-10 V

CC-E I DC /V

1SVR011773R2400

0.092
(0.207)

0-20 mA

CC-E IDC/I

1SVR011774R2500

0.091
(0.200)

4-20 mA

CC-E IDC/I

1SVR011775R2600

0.093
(0.205)

0-10 V, 0-20 mA,
4-20 mA

CC-E/I

1SVR011708R0400

0.099
(0.218)

0-10 V

CC-E IAC/V

1SVR011780R1100

0.092
(0.203)

0-20 mA

CC-E IAC/I

1SVR011781R0600

0.092
(0.207)

4-20 mA

CC-E IAC/I

1SVR011782R0700

0.095
(0.209)

0-10 V

CC-E I DC /V

1SVR011783R0000

0.093
(0.205)

0-20 mA

CC-E I DC /I

1SVR011784R0100

4-20 mA

CC-E I DC /I

1SVR011785R1100

4-20 mA

CC-E IAC /ILPO2)

1SVR010203R0500

B 1604 Class I, Div.2 (universal device)
for sinusoidal currents

4/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

0.092
(0.203)

0.095
(0.209)
0.052
(0.115)

Analog signal converters - CC-E range
DIP switch settings, Dimensional drawings

0...300 °C

0...500 °C

Legend
ON
OFF

-50...+50 °C

-50...+250 °C

-50...+450 °C

Switch
1 2 3 4 5 6

0...10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA

High fail safe
Low fail safe

CC-E/TC

TC-K:
0...1000 °C

Output

Switch
1 2 3 4 5 6

0...10 V
0...20 mA
4...20 mA
0...10 V
0...20 mA
4...20 mA

2CDC 282 003 F0204

High fail safe
Low fail safe

Legend
ON
OFF
no influence

Input
I - DC
I - AC
I - DC
I - AC
I - DC
I - AC

Output

Switch
1 2 3 4 5 6

0...10 V
0...20 mA
4...20 mA

Legend
ON
OFF

Input range selection - CC-E/I
Select input range by terminals
Input range 5 A
Connected lines
Used terminals
Terminal marking

2CDC 282 011 F0204

TC-J:
0...600 °C

CC-E/I

2CDC 282 007 F0208

Input

Legend
ON
OFF
no influence

4

2CDC 282 003 F0204

4...20 mA

0...100 °C

Output

2CDC 282 002 F0204

0...20 mA

0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V
0...10 V
0...20 mA
4...20 mA

Input

2CDC 282 005 F0208

0...10 V

Switch
1 2 3 4 5 6 7 8

2CDC 282 002 F0204

0...5 V

Output

2CDC 282 001 F0204

Input

CC-E/RTD

2CDC 282 006 F0208

CC-E/STD, CC-E x/x (universal devices)

Input range 20 A
Connected lines
Used terminals
Terminal marking

Dimensional drawings

2CDC 282 011 F0b06

22.5
0,88 "

18
0.71"

2CDC 282 012 F0b06

CC-E IAC/ILPO, CC-E I/I

CC-E/x

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/12

Analog signal converters - CC-E range
Wiring instructions
CC-E/STD, CC-E x/x (universal devices)

CC-E/RTD
G

supply

Burden
R  1.0 k

H

Burden
R  500 

J

supply

2CDC 282 007 F0206

Burden
R  500 

2CDC 282 006 F0206

Burden
R  1.0 k

4

CC-E IAC/ILPO

CC-E/TC

supply

CC-E I/I-2
Channel 1

Channel 1

input
0-20 mA or
4-20 mA

output
0-20 mA or
4-20 mA

input
0-20 mA or
4-20 mA

IN

C

F

D

E

OUT

UL
IN

OUT
RL  500 

2CDC 282 003 F0205

Channel 1

Channel 1
IN

C

F

D

E

OUT

output
0-20 mA or
4-20 mA
UL

IN

OUT
RL  500 

Channel 2
input
0-20 mA or
4-20 mA

Chanel 2
IN

A

H

B

G

OUT

output
0-20 mA or
4-20 mA
UL

IN

OUT
RL  500 

CC-E I/I

I

5A

H
V

J

IN

OUT
I

G
K
-

M
supply

+

A

+

C

-

D

+

F

-

Burden
R  1.0 k
Burden
R  500 

2CDC 282 008 F0208

20 A

4/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

2CDC 282 004 F0205

CC-E I/I-1

2CDC 282 010 F0b06

Burden
R  500 

2CDC 282 008 F0206

Burden
R  1.0 k

Analog signal converters - CC-E range
Technical data
Type
Input circuits - Analog inputs

J-G-H

CC-E/STD / CC-E x/x
Current
Voltage

CC-E/RTD 3)
Temperature sensors

(IEC 584-1 and 2)
Standard signals
PT100
TC.K, TC.J
0...20 mA / 0...5 V /
-50...+500 °C
TC.K: 0...1000 °C,
4...20 mA 0...10 V /
TC.J: 0...600 °C
-10...+10 V
+55 mA
± 11 V
< 0.01 %/
< 0.5 % / 100 
± 5 % (universal devices)
± 5 % (universal devices)
50 
1 M
> 35 dB
100 dB
D-F, A-C
Current
Voltage
0-20 mA, 4-20 mA
0-5 V, 0-10 V
 500 
1.0 K
± 0.5 % of full-scale
< 0.5 %
200 µs
10 ms
2 kHz
80 Hz
2 Hz (up to -3 dB)
High fail safe: Output voltage > 115 % of
measuring range 2)
Low fail safe: Output voltage < -0.6 V, output
current = 0 mA
K-M
DC versions
AC versions
24 V DC
110-240 V AC - 50/60 Hz
-15...+15 %
-15...+10 %
1.5 W typ.
1.5 VA typ.

Input signal
Rated input range
Limitation of input signals
Influence of line resistance
Gain adjustment range
Offset adjustment range
Input impedance
Suppression at 50 Hz
Common-mode rejection
Output circuits - Analog outputs
Output signal
Output burden
Accuracy 1)
Residual ripple
Response time
Transmission frequency
Reaction to input circuit interruption

Supply circuits
Supply voltage
Supply voltage tolerance
Power consumption
Indication of operational states
Rated control supply voltage U S

U: green LED

General data
Ambient temperature range operation / storage
Temperature coefficient
Degree of protection (DIN 40050)
Mounting position

0...+60 °C / -20...+80 °C
± 500 ppm/°C
IP20
ventilation slots on top and bottom

Mounting

DIN rail (IEC/EN 60715), snap-on mounting

Electrical connection
Wire size

rigid 0.2-4 mm 2 (24-12 AWG)
fine-strand with(out) wire end ferrule 0.2-2.5 mm 2 (24-14 AWG)
7 mm (0.28 inch)
0.5 Nm (4.4 lb.in)

Stripping length
Tightening torque
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field(HF radiation
resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference emission
Isolation data
Test voltage between all isolated circuits
Rated insulation voltage
1)
2)
3)

CC-E/TC
Thermocouples

EN 61000-6-2
IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
IEC/EN 61000-4-3 10 V/m
IEC/EN
IEC/EN
IEC/EN
EN

61000-4-4
61000-4-5
61000-4-6
61000-6-4

Level 3 (±2 kV / 5 kH)
±2 kV / ±1 kV
10 V
Class B
2.5 kV AC
-

-

-

Includes non-linearity and factory setting, influenced by supply voltage and output load.
Only -/RTD and -/TC: Single-function devices respond with Low fail safe to input signal interruptions.
When connecting a 2-wire sensor, the terminals J and H have to be jumpered.

Approvals on page 4/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/14

4

Analog signal converters - CC-E range
Technical data
Type

CC-E I/I-1 / CC-E I/I-2
Current

Input circuits - Analog inputs
Input current I IN

0-20 mA, 4-20 mA

Min. input current
Max. input current
Input voltage U IN

< 100 µA
50 mA1) (V IN < 18 V)

Input voltage drop U i

< 2.5 V (20 mA, RL = 0 )
18 V1) (I IN < 50 mA)

< 2.5 V + (I IN x R L)

Max. input voltage
Output circuits
Output current I OUT

4

0-20 mA, 4-20 mA
0-500 
I OUT x RL

Output load R L
Output voltage U OUT
Residual ripple

< 20 mVpp (500 , 20 mA)
< 15 ms (0-500 , 20 mA),
< 5 ms (500 , 20 mA, 25 °C)
 0.1 % of full-scale (20 mA)
 0.05 % / 100 ,
 -0.1 % / 100  (25 °C)

Response time (0-100 %)
Accuracy
Load influence (0-500 )
General data
Width of the enclosure
Weight
Mounting position
Degree of protection
Ambient temperature range
Temperature coefficient
Mounting
Electrical connection
Wire size
Stripping length
Tightening torque
Standards
Product standard
Low Voltage Directive
EMC Directive
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field (HF radiation
resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
magnetic fields
Interference emission
Radiated noise
Operational reliability (EN 68-2-6)
Mechanical resistance (EN 68-2-6)
Environmental testing (IEC 68-2-30 Db)
Isolation data
Insulation voltage input / output
Insulation voltage between channels
Pollution category
Overvoltage category
1)

18 mm
1 channel approx. 0.037 kg (0.082 (0.181) lb)
2 channel approx. 0.044 (0.097) kg (0.097 lb)
any
enclosure / terminals IP20 / IP20
operation / storage -25...+60 °C / -40...+85 °C
< 50 ppm / °C
DIN rail (IEC/EN 60715)
rigid 0.2-4 mm 2 (24-12 AWG)
fine-strand with(out) wire end ferrule 0.2-2.5 mm 2 (24-14 AWG)
7 mm (0,28 inch)
0.5 Nm (4.4 lb.in)
EN 50178
2006/95/EC
2004/108/EC
EN 61000-6-2
EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
EN 61000-4-3
10 V/m
EN
EN
EN
EN

61000-4-4
61000-4-5
61000-4-6
61000-4-8

Level 3 (±2 kV / 5 kH)
±2 kV / ±1 kV
10 V
30 A/m
EN 61000-6-4
EN 55011 Class B
4g
10 g
24 h cycle, 55 °C, 93 % rel., 96 h

The input parameters have to be limited to the indicated maximum values.

Approvals on page 4/4.

4/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

500 Veff / 50 Hz
5 kVeff / 50 Hz (device with 2 channels)
2
II

Analog signal converters - CC-E range
Technical data
Type
Input circuits - Analog inputs
Rated input range
Measuring frequency
Overload capacity of inputs
Gain adjustment range
Offset adjustment range
Input impedance / resistance
Output circuits - Analog outputs

AC current
0-5 A / 0-20 A

Output burden / load

Supply circuits
Supply voltage

CC-E IAC/ILPO
C-D
2 meas. ranges selectable
0-1 A / 0-5 A / sinusoidal
50/60 Hz
10 x I Nom (50 A) for max. 2 s
10 x I Nom (200 A) for max. 2 s
5 m
F-E passive current output in proportion to input current

0-20 mA /
4-20 mA

0-10 V

4-20 mA

 500 

 1.0 

12 V DC: 150 ,
24 V DC: 750 
30 V DC: 1050 

± 2 % of full-scale
±5 % (universal device)
±5 % (universal device)
< 0.5 %
0.5 s
DC or 50/60 Hz
Low fail safe: output voltage
< 200 mV, output current < 400 µA
K-M
DC versions
AC versions
110-240 V AC
24 V DC
50/60 Hz
-15...+15 %
-15...+10 %
typ 1.5 W
typ 1.5 VA

Supply voltage tolerance
Power consumption
Indication of operational states
Supply voltage
General data
Ambient temperature range operation / storage
Temperature coefficient
Degree of protection (DIN 40050)
Mounting position
Mounting
Electrical connection
Wire size
rigid
fine-strand with(out) wire end ferrule
Stripping length
Tightening torque
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
IEC/EN 61000-4-2
electromagnetic field (HF radiation resistance)
IEC/EN 61000-4-3
fast transients (Burst)
IEC/EN 61000-4-4
powerful impulses (Surge)
IEC/EN 61000-4-5
HF line emission
IEC/EN 61000-4-6
Interference emission
EN 61000-6-4
Isolation data
Test voltage (between all isolated circuits)
Rated insulation voltage
1)

DC current
0-5 A / 0-20 A

input range 1 10 x I
(50 A) for max. 1 s
Nom
input range 2 10 x I
(200 A) for max. 1 s
Nom
±5 % (universal devices)
±5 % (universal devices)
5A : 65 m
20 A : 2.5 m
D-F Current
A-C Voltage

Output signal

Accuracy 1)
Offset adjustment range
Gain adjustment range
Residual ripple
Response time
Transmission frequency
Reaction to input circuit interruption

CC-E/I
J-G-H

U: green LED

±5%
± 20 %
0.6 s
AC: 50/60 Hz
12-30 V DC
-

0...+60 °C / -20...+80 °C
-20...+60 °C / -40...+80 °C
± 500 ppm/°C
300 ppm/°C
IP20
ventilation slots on top and bottom
DIN rail (IEC/EN 60715), snap-on mounting
0.2-4 mm² (24-12 AWG)
0.2-2.5 mm² (24-14 AWG)
7 mm (0.28 inch)
0.5 Nm (4.4 lb.in)
EN 61000-6-2
Level 3 (±6 kV / ±8 kV)
10 V/m
Level 3 (±2 kV / 5 kH)
±2 kV / ±1 kV
10 V
Class B
2.5 kV AC
-

250 V AC

Includes non-linearity and factory setting, influenced by supply voltage and output load.

Approvals on page 4/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/16

4

Analog signal converters - CC-U range
Product group picture

4

4/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Analog signal converters - CC-U range
Table of contents

Analog signal converters - CC-U range
Overview

4/19

Ordering details

4/21

Ordering details - Accessories

4/22

DIP switch settings

4/23

Wiring instructions

4/25

Technical information

4/26

Technical data

4/29

Technical diagr., Connection diagr., Dimensional drawings

4/32

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/18

4

Analog signal converters - CC-U range
Overview

4

CC-U range
– – 8 different standard signal outputs on one device
– – Input and output side universally configurable
– – Also available with 2 threshold relay outputs
– – Adjustment and operating elements on the front side
– – Safe operation by electrical 3-way isolation
– – Plug-in connecting terminals, unambiguously and clearly
­m arked
Conversion, measurement and separation of
– – Standard signals
– – Signals of RTD sensors (PT10, PT100, PT1000)
– – Thermocouple signals
– – TRMS values of currents and voltages

Characteristics
– – The required input and output ranges can be configured
for all devices by means of directly accessible DIP switches
positioned on the side.
– – Due to the wide input range of the gain and offset stages
all input signals between the minimum and the maximum
input value can be universally converted to all common
output signals.
– – Devices for DC or AC (50/60 Hz) supply available.

1 Terminals +, V/I+, V/I-, PW DC, IN, 2 Terminal explanation
3 Adjustment of resistance value R1

1

4 Adjustment of hysteresis
4 Adjustment of resistance value R2

Adjustment of hysteresis

2

3

7 Indication of operational states
R1 yellow LED - resistance value R1
R2 yellow LED - resistance value R2
U green LED - supply voltage

8 Marker label

4
5

7
8

2

1

4/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Analog signal converters - CC-U range
Overview
CC-U/STD universal signal converter with 3-way electrical
isolation
–– More than 120 configurations possible
–– Configurable output signal response on input voltage signal
interruption (low fail safe / high fail safe)
–– Adjustment and operating elements on the front
–– Short-circuit proof signal outputs
–– Plug-i connecting terminals for inputs, outputs and supply
–– Very fast signal transmission enables use in control systems

CC-U/RTD universal signal converter for PT10, PT100,
PT1000 temperature sensors (acc. to IEC 751 and JIS C
16041), linearized with 3-way electrical isolation)
–– Configurable output signal response on input signal interruption (low / high fail safe)
–– Adjustment and operating elements on the front-side
–– Short-circuit proof signal outputs
–– Plug-in connecting terminals for inputs, outputs and supply
–– 2- or 3-wire connection
1)

Japanese standard

CC-U/STDR universal signal converter for standard
signals, with 2 threshold relay outputs and with 3-way
electrical isolation
– – Standard signal converter with 7 setting ranges
– – 2 threshold relay outputs with one c/o contact each
(threshold and respective hysteresis can be
adjusted independently from each other)
– – Open-circuit or closed-circuit principle configurable by
means of a DIP switch
– – 2 yellow LEDs for clear status indication of the output
relays
– – Plug-in connecting terminals for inputs, outputs and supply
CC-U/RTDR universal signal converter for temperature
and resistance signals, with 2 threshold relay outputs and
3-way electrical isolation
– – Temperature signal converter for PT100 signals (5 ranges up
to 800 °C) and variable resistances from 0-380 q
– – 2 threshold relay outputs with one c/o contact each (threshold and respective hysteresis can be adjusted independently
from each other)
– – Open-circuit or closed-circuit principle configurable by
means of a DIP switch
– – 2 yellow LEDs for clear status indication of the output relays
– – Plug-in connecting terminals for inputs, outputs and supply
– – 2- or 3-wire connection

CC-U/TC universal signal converter for thermocouples
with 3-way electrical isolation
–– Temperature signal converter for thermo-couples of the
types K, J, T, S, E, N, R, B
–– Continuously adjustable voltage signal input 0-10 mV and
0-50 mV
–– Differential temperature meas. possible (see wiring instructions page
4/17)
–– Configurable output signal response on input signal interruption (low fail safe / high fail safe)
–– Adjustment and operating elements on the front-side
–– Short-circuit proof signal outputs
–– Plug-in connecting terminals for inputs, outputs and supply
–– Cold-junction compensation selectable

CC-U/TCR universal signal converter for thermocouples,
with 2 threshold relay outputs and 3-way electrical
isolation
– – Temperature signal converter for thermocouples of the
types K, J, T, S
– – 2 threshold relay outputs with one change-over contact
each (threshold
and respective hysteresis can be
adjusted independently from each other)
– – Open-circuit or closed-circuit principle configurable by
means of a DIP switch
– – 2 yellow LEDs for clear status indication of the output
relays
– – Plug-in connecting terminals for inputs, outputs and supply
– – Integrated cold-junction compensation

CC-U/V universal measuring converter for RMS values of
0-600 V, with 3-way electrical isolation
–– RMS converter for voltage signals up to 600 V of any wave
form (DC, DC with superimposed AC components, pure
sinusoidal, triangular, phase-angle controlled, etc. in a
measuring range of 0-600 Hz)
–– Adjustment and operating elements on the front
–– Short-circuit proof signal outputs
–– Plug-in connecting terminals for inputs, outputs and supply

CC-U/I universal measuring converter for RMS values of
0-1 A and 0-5 A, with 3-way electrical isolation
– – RMS converter for current signals up to 1 A and up to 5
A of any wave
form (DC, DC with superimposed
AC components, pure sinusoidal, triangular, phase-angle
controlled, etc. in a measuring range of 0-600 Hz)
– – Adjustment and operating elements on the front
– – Short-circuit proof signal outputs
– – Plug-in connecting terminals for inputs, outputs and supply

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/20

4

Analog signal converters - CC-U range
Ordering details
Ordering details - Standard Signal Converters

2CDC 281 003 F0003

Supply
voltage range

Output signal

Type

Order code

Price
1 pce

0.125
(0.276)
0.126
(0.278)

1SVR040000R1700
refer to table

CC-U/STD
1SVR040001R0400

refer to table
2 c/o

CC-U/
STDR1)

Weight
(1 pce)
kg (lb)

1SVR040010R0000

0.142
(0.313)

1SVR040011R2500

CC-U/STDR

Ordering details - RTD Converters
Supply
voltage range

Input signal

2CDC 281 005 F0003

CC-U/RTD

110-240 V AC,
100-300 V DC
24-48 V DC,
24 V AC

Output signal

Type

Order code

Price
1 pce

24-48 V DC,
24 V AC

refer to table

1SVR040002R0500

0.126
(0.278)

1SVR040003R0600

0.128
(0.282)

1SVR040012R2600

0.146
(0.322)

1SVR040013R2700

0.148
(0.326)

CC-U/RTD

refer to table
2 c/o

110-240 V AC,
100-300 V DC

Weight
(1 pce)
kg (lb)

CC-U/RTDR1)

Ordering details - Thermocouple Converters
Supply
voltage range

Input signal

2CDC 281 008 F0003

CC-U/TC

110-240 V AC,
100-300 V DC
24-48 V DC,
24 V AC

Output signal

Type

Order code

Price
1 pce

24-48 V DC,
24 V AC

refer to table

1SVR040004R0700

0.130
(0.287)

1SVR040005R0000

0.128
(0.282)

CC-U/TC

refer to table
1SVR040014R2000
2 c/o

110-240 V AC,
100-300 V DC

Weight
(1 pce)
kg (lb)

0.145
(0.320)

CC-U/TCR1)
1SVR040015R2100

Ordering details - Measuring Converters
Supply
voltage range

Input signal

Output signal

CC-U/I

110-240 V AC,
100-300 V DC
24-48 V DC,
24 V AC

2)
3)

Order code

Price

refer to table

0.128
(0.282)

1SVR040007R0200

0.127
(0.280)

refer to table

with relay output
for current RMS values
for voltage RMS values

4/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Weight
(1 pce)
kg (lb)

1SVR040006R0100
CC-U/I2)

110-240 V AC,
100-300 V DC
1)

Type

1 pce

24-48 V DC,
24 V AC
2CDC 281 012 F0003

4

24-48 V DC,
24 V AC
110-240 V AC,
100-300 V DC
24-48 V DC,
24 V AC
110-240 V AC,
100-300 V DC

Input signal

1SVR040008R1300
CC-U/V3)
1SVR040009R1400

0.128
(0.282)

10
.394”
22,5
.886”

62,5 2.46”

2CDC 252 187 F0005

4,5
.177”

11,5
.453”

Analog signal converters - CC-U range
Ordering details - Accessories
Ordering details - Accessories
For type

CC-U

60 2.36”

ADP.01

Width in mm

Type

Order code

22.5

ADP.01

1SVR430029R0100

1

18.4
(0.65)

MAR.01

1SVR366017R0100

10

0.19
(0.007)

COV.01

1SVR430005R0100

1

5.2
(0.18)

MAR.01

7 .275”
3,5 .138”

68,5 2.70 ”

22,5
.886”

22.5

Pkg
qty

Weight
(1 pce)
g (oz)

4
2CDC 252 185 F0005

20
.787”

CC-U

2CDC 252 186 F0005

3A11

8
.315”

CC-U

Price

front-to-back
size 107

Sealable cover - COV.01

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/22

Analog signal converters - CC-U range
DIP switch settings

Input
Switch 1
Switch 2
Range
1 2 3 4 5 6 1 2 3 4 5 6
0...500 °C
0...550 °C
0...600 °C
0...650 °C
PT10
0...700 °C
0...750 °C
0...800 °C
0...850 °C
0...50 °C
0...60 °C
0...70 °C
0...80 °C
0...90 °C
PT100 0...100 °C
0...200 °C
0...300 °C
0...400 °C
0...500 °C
0...10 °C
0...20 °C
0...30 °C
PT1000 0...40 °C
0...50 °C
0...60 °C
Low fail safe *)
High fail safe *)
Type

CC-U/RTDR with relay output

Output
Closed-circuit principle
Open-circuit principle

Switch
1 2 3 4 5 6

Legend
ON
OFF
no influence

2CDC 282 003 F0204

0...100 °C
0...200 °C
0...400 °C
0...600 °C
0...800 °C

Legend
ON
OFF
no influence

CC-U/RTD

Output

Input PT100

2CDC 282 005 F0204

Output
Closed-circuit principle
Open-circuit principle

4/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
0...8 V
0...4 V
-10...-2 V
-5...-1 V
1.25...6.25 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...0.5 mA
0...13.33 mA
0...666 µA
0...16 mA
0...800 µA
0...8 mA
0...400 µA
2.5...12.5 mA
125...625 µA
3.33...16.66 mA
166...833 µA
0.2...1 mA
2...10 mA
100...500 µA

Switch 3
1 2 3 4 5 6

Legend
ON
OFF
no influence

Gain
Coarse
F
E
D
C
B
A
9
8
F
E
B
A
9
8
3
2
1
0
8
3
2
1
0
0
-

*) Detection of input signal
interruptions:
If the input signal circuit
is interrupted, the output
signal changes to the
adjusted minimum value
(low fail safe) or maximum
value (high fail safe).

2CDC 282 023 F0203

Legend
ON
OFF
no influence

Switch
1 2 3 4 5 6

2CDC 282 003 F0204

*) Detection of input voltage signal
interruptions:
If the input signal circuit is interrupted, the output signal changes
to the adjusted minimum value (low
fail safe) or maximum value (high fail
safe).
If "No fail safe" is configured,
input signal interruptions are not
detected.

Input
0...10 V
0...5 V
0...1 V
-10...+10 V
1...5 V
0...20 mA
4...20 mA

0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
0...8 V
0...4 V
-10...-2 V
-5...-1 V
1.25...6.25 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...0.5 mA
0...13.33 mA
0...666 µA
0...16 mA
0...800 µA
0...8 mA
0...400 µA
2.5...12.5 mA
125...625 µA
3.33...16.66 mA
166...833 µA
0.2...1 mA
2...10 mA
100...500 µA

2CDC 282 024 F0203

0
A...D
4...5
0...1
7...9
3...4
0
5...7
2
7...9
2...4
0
3...4
3...4
B...F
0
5...7
3...4
2
4...5
A...D
2...4
4...5
0...1
4...5
4...2
B...F
4...6
-

Switch 2
1 2 3 4 5 6

Output

2CDC 282 020 F0203

Potentiometer
0...50 mV
0...100 mV
0...250 mV
0...500 mV
0...1 V
0...2.5 V
0...5 V
0...10 V
1...5 V
2... 10 V
-10...+10 V
0...125 mV
0...8 V
-22.5...+22.5 mV
-11...+11 V
2.5...7.5 V
3.33...9.99 V
10...0 V
100...0 mV
0...1 mA
0...20 mA
4...20 mA
10...50 mA
20...4 mA
20...0 mA
-0.45...+0.45 mA
-55...+55 mA
High fail safe *)
Low faile safe *)
No fail safe *)

Coarse
Type
0
C
5
1
8
3
0
6
2
8
3
0
3
3
D
0
6
4
2
5
B
3
4
1
4
3
D
5
-

2CDC 282 003 F0204

Gain

2CDC 282 007 F0204

4

Switch 1
1 2 3 4 5 6 7 8

2CDC 282 019 F0203

Input

CC-U/STDR with relay output

2CDC 282 003 F0204

CC-U/STD

Analog signal converters - CC-U range
DIP switch settings

2CDC 282 029 F0203
Legend
ON
OFF
no influence

Type

*) Detection of input signal
interruptions:
If the input signal circuit is interrupted, the output
signal changes to the adjusted minimum value (low
fail safe) or maximum value (high fail safe).

Legend
ON
OFF
no influence

0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
0...8 V
0...4 V
-10...-2 V
-5...-1 V
1.25...6.25 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...0.5 mA
0...13.33 mA
0...666 µA
0...16 mA
0...800 µA
0...8 mA
0...400 µA
2.5...12.5 mA
125...625 µA
3.33...16.66 mA
166...833 µA
0.2...1 mA
2...10 mA
100...500 µA

J

K

T

S

Input
Switch
Range
1 2 3 4 5 6
0...240 °C
0...480 °C
0...1200 °C
0...250 °C
0...500 °C
0...1350 °C
-150...+120 °C
0...220 °C
0...400 °C
0...210 °C
0...380 °C
0...860 °C
0...1550 °C
Output

Closed-circuit principle
Open-circuit principle

Legend
ON
OFF
no influence

2CDC 282 003 F0204

2CDC 282 029 F0203

Legend
ON
OFF
no influence

2CDC 282 003 F0204

Type

Switch
1 2 3 4 5 6

2CDC 282 004 F0204

CC-U/TCR with relay output

CC-U/I
Output

Input
Switch 1
Switch 2
Range
1 2 3 4 5 6 1 2 3 4 5 6
0-100...900 °C
K 0-250...1350 °C
J
0-100...750 °C
0-100...400 °C
T -150-0...400 °C
S 0-250...1550 °C
0-100...700 °C
E 0-200...1000 °C
0-100...650 °C
N 0-200...1300 °C
0-250...1350 °C
R
0-450...1700 °C
B 0-700...1750 °C
0-2...10 mV
mV 0-10...50 mV
Low fail safe *)
High fail safe *)

Switch 3
1 2 3 4 5 6

0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
0...8 V
0...4 V
-10...-2 V
-5...-1 V
1.25...6.25 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...0.5 mA
0...13.33 mA
0...666 µA
0...16 mA
0...800 µA
0...8 mA
0...400 µA
2.5...12.5 mA
125...625 µA
3.33...16.66 mA
166...833 µA
0.2...1 mA
2...10 mA
100...500 µA

2CDC 282 010 F0204

Output

2CDC 282 003 F0204

Switch
1 2 3 4 5 6

0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
0...8 V
0...4 V
-10...-2 V
-5...-1 V
1.25...6.25 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...0.5 mA
0...13.33 mA
0...666 µA
0...16 mA
0...800 µA
0...8 mA
0...400 µA
2.5...12.5 mA
125...625 µA
3.33...16.66 mA
166...833 µA
0.2...1 mA
2...10 mA
100...500 µA

2CDC 282 003 F0204

Output

CC-U/TC

2CDC 282 017 F0208

CC-U/V

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/24

4

Analog signal converters - CC-U range
Wiring instructions
CC-U/STD

CC-U/STDR with relay output
G Pot.

H

Burden
R  600 

Value R1

supply

Threshold

Hysteresis

2CDC 282 016 F0206

J

Burden
R  4.7 k
2CDC 282 015 F0206

Value R2

4
supply

CC-U/RTD

CC-U/RTDR with relay output
G

Value R1

Burden
R  600 

H

supply

G

υ

J

Threshold

R1

E (12)
F (11)
D (14)

R2

B (22)
C (21)
A (24)

Hysteresis

H
Value R2

K

M
supply

CC-U/V

2CDC 282 045 F0203

J

2CDC 282 017 F0206

Burden
R  4.7 k

CC-U/I
Burden
R  4.7 k

Burden
R  4.7 k

supply

Burden
R  600 

2CDC 282 022 F0206

Burden
R  600 

CC-U/TC

supply

2CDC 282 021 F0206

+ 2.5 V

CC-U/TCR with relay output
Value R1

supply

Threshold

Hysteresis

Value R2

without cold-junction compensation:
switch SW2.2 = OFF

2CDC 282 019 F0206

supply

4/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

2CDC 282 020 F0206

Burden
R  600 

2CDC 282 018 F0206

Burden
R  4.7 k

Analog signal converters - CC-U range
Technical information
CC-U/STD
Adjustment range
OUT [%]
100
Gain
“gain-coarse”
and
“gain-fine”

90
80
70
60
50
40
30

4



20
10

IN [%]
10 20 30 40 50 60 70 80 90 100

Offset remote poti

SW1.4 = +100 %
SW1.5 = +50 %

2CDC 282 018 F0203

SW1.6 = +22.5 %

CC-U/STDR with relay output
Function diagrams

Switching points

Closed-circuit principle

Switching points of the output relay depending on the input range,
configuration open-circuit principle

R1 Threshold value
R1 Hysteresis

IN [%]

Input

11-14
R1 11-12
21-24
R2 21-22

va
lu

e

100

tu
al

90
Threshold value R1
2-100 %
of input range

Ac

R2 Threshold value

2CDC 282 044 F0203

R2 Hysteresis

80

Hysteresis R1
5-50 % of
threshold
value R1

70
60

Open-circuit principle
50

R1 Threshold value
R1 Hysteresis

40
Threshold value R2
2-100 %
of input range

R2 Threshold value

11-14
R1 11-12
21-24
R2 21-22

2CDC 282 046 F0203

R2 Hysteresis

30
20

Hysteresis R2
5-50 % of
threshold
value R2

10
0
R1

11-14
11-12

R2

21-24
21-22

OUT

2CDC 282 021 F0203

Input

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/26

Analog signal converters - CC-U range
Technical information
CC-U/RTD
Characteristic curves
Resistance of PT10, PT100 and PT1000 sensors depending on the temperature

PT100

2CDC 282 022 F0203

PT10

Temperature [°C]

CC-U/RTDR with relay output
Switching points

Function diagrams

Switching points of the output relay depending on the input range,
configuration open-circuit principle
IN [%]

Closed-circuit principle
R1 Threshold value
R1 Hysteresis

100

Input

va

lu

e
tu

600
500

Ac

Threshold value R1
2-100 %
of input range

80

R2 Threshold value

Hysteresis R1
5-50 % of
threshold
value R1

70
60

11-14
R1 11-12
21-24
R2 21-22

50

400
300

Threshold value R2
2-100 %
of input range

200

40
30
20

100

Open-circuit principle
R1 Threshold value

Hysteresis R2
5-50 % of
threshold
value R2

R1 Hysteresis
Input

10

R2 Hysteresis

100

150

200

250

300

350

Resistance []

OUT

400
R1

11-14
11-12

R2

21-24
21-22

R2 Threshold value

2CDC 282 025 F0203

0
50

2CDC 282 044 F0203

R2 Hysteresis

al

90

700

2CDC 282 046 F0203

800

Temperature υ [°C]

11-14
R1 11-12
21-24
R2 21-22

CC-U/V
Input range selection
Switch
position
1
2
3
4
5
6
7
8

RMS measurement and conversion of a phase-angle controlled voltage signal L1 = 230 V

INUeff [V]
U(t) [V]

300

resulting
RMS value

Gain 15 %

OUT [%]

0
0
Offset 20 %
-300
operating angle

4/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

50

100

2CDC 282 030 F0203

Selecting input range by
front-face rotary switch
0...100 V
0...150 V
0...250 V
0...300 V
0...400 V
0...450 V
0...550 V
0...600 V

Example of application

2CDC 282 012 F0204

4

Resistance []

PT1000

Analog signal converters - CC-U range
Technical information
CC-U/I
Input range selection

Example of application
RMS measurement and conversion of a current signal
IN [%]

Select input range by terminals

Gain 15 %

Input range 1 A
J

H

5A

I(t) [A]

G

1A

C

Input range 5 A
Connected lines
Used terminals
Terminal marking

J

H

5A

G

1A

5

2CDC 282 033 F0203

Connected lines
Used terminals
Terminal marking

C

4
3
2

resulting
RMS value

1
0

t

-1

0

50

4

OUT [%]

100

-2
2CDC 282 028 F0203

Offset 20 %

-3
-4
-5

CC-U/TC
Characteristic curve
Thermocouple voltages depending on the temperature
80000

Typ E

75000

Typ J

70000
65000
60000

Typ K

55000
50000

Typ N

Thermoelement-Spannung [µV]

45000
40000
35000
30000
25000

Typ R
Typ T

20000

Typ S

15000
10000

Typ B

5000
0

-10000

1800

1750

1700

1650

1600

1550

1500

1450

1400

1350

1300

1250

1200

1150

1100

1050

950

900

850

1000

800

750

700

650

600

550

500

450

400

350

300

250

200

150

0

50

100

-50

-100

-150

-200

-250

-15000

Temperatur [°C]

2CDC 282 026 F0103

-5000

CC-U/TCR with relay output
Function diagrams

Switching points

Switching points of the output relay depending on the
input range, configuration open-circuit principle

Closed-circuit principle
R1 Threshold value
R1 Hysteresis

IN [%]

Input

Typ K
Release hysteresis

4500
4000
3500

Threshold value
R2 = 400 °C

3000
2500

Typ T

Release hysteresis

2000
1500

Typ S

1000
500

R1

R2

21-24
21-22

1825

1725

1625

1525

1425

1325

1225

925

1125

825

Temperature [°C]

1025

725

625

525

425

325

225

25

-1500

11-14
11-12

OUT
2CDC 282 027 F0203

0

0
-500
-1000

-75

11-14
R1 11-12
21-24
R2 21-22

2CDC 282 046 F0203

R2 Threshold value

5000

125

Input
R2 Hysteresis

5500

-175

R1 Threshold value
R1 Hysteresis

6000

-275

Open-circuit principle

Threshold value
R1 = 1000 °C

Typ J

6500

Thermocouple voltage [µV]

11-14
R1 11-12
21-24
R2 21-22

2CDC 282 044 F0203

R2 Threshold value

100

7000

R2 Hysteresis

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/28

Analog signal converters - CC-U range
Technical data
Type

CC-U/STD

Input circuits - Analog inputs

J-G-H

Current

meter
0-100 mV 470 
0-1 V
-1 M 2)
0-5 V
1-5 V
0-10 V
2-10 V
± 10 V
± 55 mA ± 11 V
0-20 mA
4-20 mA
10-50 mA
0-1 mA

Input signal

Limitation of input signals
Rated input range

4
Influence of line resistance
Gain adjustment range
(universal devices)
Offset adjustment range (universal devices)
Input impedance
without detection of input signal interruption
with detection of input signal interruption
Suppression at 50 Hz
Common-mode rejection
Output circuits - Analog outputs
Output signal

0.945 mV - 110 mA 22 V
-137.5...+62.5 %
for different ranges
51 
6 M
3 G
51 
3.5 M 9.5 G
Current
D-F, A-C
0-20 mA, 4-20 mA
 600 
±0.1 % of full-scale
200 µs
1 kHz
DC versions
K-M
24-48 V DC
24-48 V DC / 24 V AC
DC: -15...+15 %
0 Hz or 50/60 Hz
2 W at 24 V DC

Output burden
Accuracy 1)
Residual ripple
Response time
Transmission frequency
Supply circuits
Rated supply voltage
Supply voltage range
Supply voltage tolerance
Rated frequency
Power consumption
Indication of operational states
Supply voltage
General data
Ambient temperature range operation / storage
Temperature coefficient

Mounting position
Mounting
Electrical connection
Wire size

3)

(IEC 584-1 and 2)
TC.K
TC.J
TC.T
TC.S
TC.E
TC.N
TC.R
TC.B

Max. temperature
refer to
adjustable:
temperature
6-60 °C for PT1000 specs. of individual
50-500 °C for PT100 thermocouples
500-850 °C for PT10
0.015 °C/
< 0.01 % / 100 
see DIP switch settings
±5%
120 dB

± 10 %
> 40 dB
105 dB
Voltage
0-5 V, 1-5 V, 0-10 V, 2-10 V, ± 10 V

 4.7 K
±0.2 % of full-scale ±0.1 % of full-scale
< 0.15 %
10 ms
200 ms
80 Hz
2 Hz (to -3 dB)
AC versions
110-240 V AC
110-240 V AC / 100-300 V DC
AC: -15...+10 %
4.5 VA at 230 V AC

U: green LED
-20...+60 °C / -40...+80 °C
±150 ppm/°C

±250 ppm/°C

±200 ppm/°C at
min. offset
±400 ppm/°C at
max. offset

rigid plug-connector with screw terminals 0.2-2.5 mm 2 (24-12 AWG)
fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm 2 (24-12 AWG)
7 mm (0.28 inch)
0.4 Nm (3.5 ib.in)

Test voltage (between all isolated circuits)
2)

sors
PT10, PT100,
PT1000
(IEL 751 and JICC
1604)

CC-U/TC
Thermocouples

any
DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter

Stripping length
Tightening torque
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field (HF radiation resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference emission
Isolation data
Isolation test (between all isolated circuits)

1)

CC-U/RTD 3)

Voltage Potentio- Temperature sen-

IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
EN 61000-6-4

EN 61000-6-2
Level 3 (±6 kV / ±8 kV)
10 V/m
Level 3 (±2 kV / 5 kH)
±2 kV / ±1 kV
10 V
Class B
1.5 kV
1.5 kV / 50 Hz

Includes non-linearity and factory setting, influenced by supply voltage and output load.
Detection of an input signal break (fail safe) and resistance > 10 kq results in a linearity of w0.2 %.
When connecting a 2-wire sensor, the terminals J and H have to be jumpered.

Approvals on page 4/4.
4/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Analog signal converters - CC-U range
Technical data
Type

CC-U/STDR

Input circuits - Analog inputs

J-H

Input resistance
Adjustable threshold
Adjustable hysteresis
Repeat accuracy (constant parameters)
Output circuits - Relay outputs
Rated switching voltage
Rated switching c
­ urrent

E-D-F, B-C-A

AC-12 (resistive) 230 V
AC-15 (inductive) 230 V
DC-12 (resistive) 24 V
DC-13 (inductive) 24 V
Utilization category (Control Circuit Rating Code)
max. rated operational voltage
max. continuous thermal current at B 300
max. making/breaking apparent power at B 300

Minimum switching voltage
Minimum switching current / power
Response time
Mechanical lifetime
Electrical lifetime
Supply circuits
Rated supply voltage
Supply voltage range
Supply voltage tolerance
Rated frequency
Power consumption
Indication of operational states
Supply voltage
1st / 2nd output relay energized
General data
Ambient temperature range
Temperature coefficient
Mounting position
Mounting
Electrical connection
Wire size

at AC-12, 230 V, 4 A
K-M

CC-U/RTDR 1)

CC-U/TCR

Temperature sensors

Thermocouples

(IEC 584-1 and 2)
0-1 V /
PT100
TC.K, TC.J
1-5 V
TC.T, TC.S
0-10 /
±10 V
approx.
approx.
50 
1.5 M
2-100 % of selected input range
5-50 % of threshold
±0.5 % of full-scale
Relay, 2 c/o contacts
250 V AC
4A
3A
4A
2A
B 300
300 V AC
5A
3600/360 VA
12 V
10 mA / 0.6 VA (W)
10 ms
30 x 10 6 switching cycles
0.1 Mio. switching cycles
DC versions
AC versions
24-48 V DC
24-48 V DC / 24 V AC
DC: -15...+15 %
0 Hz or 50/60 Hz
2 W at 24 V DC

110-240 V AC
110-240 V AC / 100-300 V DC
AC: -15...+10 %
4.5 VA at 230 V AC

U: green LED
R1: yellow LED / R2: yellow LED
operation / storage -20...+60 °C / -40...+80 °C
±300 ppm/°C
any
DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter
2
rigid plug-connector with screw terminals 0.2-2.5 mm (24-12 AWG)
2
fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm (24-12 AWG)
7 mm (0.28 inch)
0.4 Nm (3.5 ib.in)

Stripping length
Tightening torque
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field (HF radiation resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference emission
Isolation data
Insulation voltage (between all isolated circuits)
Test voltage (between all isolated circuits)
1)

Voltage

0-20 mA
4-20 mA

Measuring signal / input range

AC rating
(UL 508)

Current

IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
EN 61000-6-4

EN 61000-6-2
Level 3 (±6 kV / ±8 kV)
10 V/m
Level 3 (±2 kV / 5 kH)
±2 kV / ±1 kV
10 V
Class B
2.5 kV
2.5 kV

When connecting a 2-wire sensor, the terminals J and H have to be jumpered.

Approvals on page 4/4.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/30

4

Analog signal converters - CC-U range
Technical data
Type
Input circuits - Analog inputs

J-G-H
0-1 A
0-5 A

Rated input range

Gain adjustment range
Offset adjustment range
Input impedance / resistance
Output circuits - Analog outputs
Output signal
Output load
Accuracy1)
Temperature coefficient
Residual ripple
Response time
Supply circuits
Rated supply voltage
Supply voltage range
Supply voltage tolerance
Rated frequency
Power consumption
Indication of operational states
Supply voltage
General data
Ambient temperature range
Mounting position
Mounting
Electrical connection
Wire size

RMS measurement

RMS measurement
0-100 V, 0-150V, 0-250 V
0-300 V, 0-400 V, 0-450 V
0-550 V, 0-600 V
-

> 800 k
Voltage
0-5 V, 1-5 V, 0-10 V, 2-10 V, ± 10 V
 4.7 K
±300 ppm/°C max.

AC versions
110-240 V AC
110-240 V AC, 100-300 V DC
AC: -15...+10 %
4.5 VA at 230 V AC

U: green LED
operation / storage -20...+60 °C / -40...+80 °C
any
DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter
rigid plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
7 mm (0.28 inch)
0.4 Nm (3.5 lb.in)

Stripping length
Tightening torque
Standards
Product standard
Low Voltage directive
EMC directive
RoHS directive
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field (HF radiation resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference emission
Isolation data
Insulation voltage (between all isolated circuits)
Test voltage (between all isolated circuits)
1)

CC-U/V
any voltage signals,

0-600 Hz
input range 1 10 x I Nom (10 A) for max. 2 s
input range 2 10 x I Nom (50 A) for max. 2 s
±15 %
±20 %
1A: 60 m,
5 A: 12 m
Current
D-F, A-C
0-20 mA, 4-20 mA
 600 
±0.5 % of full-scale
±250 ppm/°C max.
< 0.15 %
150 ms
DC versions
K-M
24-48 V DC
24-48 V DC, 24 V AC
DC: -15...+15 %
0 Hz or 50/60 Hz
2 W at 24 V DC

Measuring frequency
Overload capacity of inputs

4

CC-U/I
any current signals,

2006/95/EC
2004/108/EC
2011/65/EC

IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
EN 61000-6-4

EN 61000-6-2
Level 3 (±6 kV / ±8 kV)
10 V/m
Level 3 (±2 kV / 5 kH)
±2 kV / ±1 kV
10 V
Class B
1.5 kV
1.5 kV / 50 Hz

Includes non-linearity and factory setting, influenced by supply voltage and output load.

Approvals on page 4/4.

4/31 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Analog signal converters - CC-U range
Technical diagr., Connection diagr., Dimensional drawings
Technical diagrams
Load limit curves CC-U/xxR
Resistive DC load

L

K

J

H

G

4

1.0
0.9
0.8

D

E

F

A

B

C

2CDC 282 023 F0b06

Derating curve

M

2CDC 282 026 F0b06

2CDC 282 025 F0b06

Resistive AC load

Connection diagram CC-U/x
Width 22.5 mm (0.89 in)

F
0.7

0.5

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

cos

Dimensional drawings

0.9

1.0

2CDC 282 014 F0b06

0.6

Dimensions in mm and inches

.039

2CDC 282 024 F0b06

CC-U/x , CC-U/xR

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/32

Serial data converters
Product picture

4

4/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Serial data converters
Table of contents

Serial data converters
Benefits and advantages

4/35

Selection table

4/36

Ordering details

4/37

Technical information

4/38

Technical data

4/46

4

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/34

Serial data converters
Benefits and advantages
ILPH RS 232 - 485 / Ethernet
–– Electrical isolation between power supply and input/output
–– RS232 on SUBD 9 points or screw connectors
–– RS485 on removable screw connectors
–– Ethernet 10/100 Mbit/s, RJ45 connector
–– Power supply 10-34 VDC and 10-24 VAC
–– Possible to have a redundant 10-34 VDC power supply
–– Economic with low consumption
–– Up to 100m with CAT5 cable without Hub or Switch
–– Good EMC characteristics
–– Up to 2 Modbus®\TCP Masters

4

Available modes:
–– Modbus®\TCP to Modbus® RTU
–– Transparent Client or Server mode
–– SMTP mode (Mail mode)
Standards: TPC/IP, TELNET, DHCP, FTP
–– Specifics functions in Modbus® protocol:
–– Concentrator (Asynchronous mode) up to 1200 words
–– AC31 programming
Modbus® Easy Net mode : this mode could be used to
exchange data without a Modbus®/TCP master. The data
are logged in a table and could be distributed to one or all
the others e-ILPH participants on Ethernet.
ILPH RS 232 / RS 422 - 485
–– Electrical isolation between power supply and input/output
–– RS 485 switch on 2 or 4 wires
–– Baudrate up to 38.4 kbit/s
–– Transmission distance up to 1200 m
–– RS 485 1 or 2 pair handling
–– Usable in "noisy" environments
–– 24...48 V DC and 115...230 V AC power supply
–– CE marked
ILPH RS 422 - 485 / RS 422 - 485
Electrical isolated connection between an RS 422-485 (1 or 2
pairs) and an RS 422 485 (1 or 2 pairs) serial link. It amplifies
the signal beyond the 1200 m limit distance of the RS 422485 and only needs a minimum of 1.5 character delay time to
switch off the RS 485 drivers.
–– Electrical isolation between power supply/output and input/
output
–– Baudrate up to 500 kbit/s (up to 200 m)
–– Transmission distance up to 1200m at 38.4 kbit/s
–– Usable in "noisy" environments
–– 2/4 wires automatic handling
–– 24 V DC power supply
–– CE marked

ILPH RS 232 / RS 422 - 485
RS 232 to RS 422-485 serial link with or without electrical
isolation
–– Baudrate up to 38.4 kbit/s
–– Transmission distance up to 1200 m
–– RS 485 1 or 2 pair handling
–– Usable in "noisy" environments
–– 24 V DC power supply
–– CE marked

ILPH RS 485 / FO
Converter for RS 485 (1 pair) to optical fiber serial link glass.
– – Electrical isolation between power supply and input/output
– – Baud rate up to 1.5 Mbit/s
– – Transmission distance up to 4 km
– – Usable in "very noisy" environments
– – 20...42 V AC/DC power supply
– – CE marked
ILPH RS 232 / CL
Electrical isolated Converter for RS 232 to current loop serial
link.
– – Electrical isolation between power supply/current loop and
RS 232/current loop
– – Active/Passive 0...20 mA / 4...20 mA selectable
Positive or negative logic selectable
– – Baudrate up to 38.4 kbit/s
– – Transmission distance up to 1200 m
– – Usable in "noisy" environments
– – 24 V DC power supply
– – CE marked
ILPH RS 232 / RS 232
3 way electrical isolator between RS 232 serial interface and
another RS 232 serial interface.
–– Ensures triple insulation between the 2 serial interfaces and
between each and power supply
–– Baudrate up to 19.2 kbit/s (up to 64 kbit/s depending on cable)
–– Transmission distance up to 15 m
–– Can be used in "noisy" environments
–– Power supply from 24...48 V DC and 115...230 V AC CE
marking

ILPH RS 232 / FO
– – Converter for RS 232 to fiber optical serial link glass.
– – Electrical isolation between power supply and input/output
– – Baud rate up to 115.2 kbit/s
– – Transmission distance up to 4 km
– – Usable in "very noisy" environments
– – 20...42 V AC/DC power supply
– – CE marked

ILPH CL / RS 422 - 485
Electrical isolated converter for current loop to RS 422-485 (1
or 2 pairs) serial link.
– – Electrical isolation between power supply/current loop and
RS 422-485/current loop
– – Active/passive 0...20 mA / 4...20 mA selectable
Positive or negative logic selectable
– – Baudrate up to 38.4 kbit/s (up to 2400 m)
Transmission distance up to 2400 m (1200 m RS 485 and
1200 m current loop)
– – Usable in "noisy" environments
– – 24 V DC power supply
– – CE marked

4/35 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

RS 232

10-34 VDC, 10-24 VAC

24-42 V AC/DC

110-240 V AC

24-48 V DC

24 V DC

Ethernet

FO-S

CL

RS 422 / RS 485

RS 232

Serial data converters
Selection table

Insulation
IN=Input
PS=Power supply
Out=Output
Wi=Without
insulation
In-Ps-Out

Part numbers
1SNA 684 234 R2000

Wi

1SNA 684 231 R2500

In-Out

1SNA 684 233 R2700

In-Ps-Out

1SNA 684 333 R2300

In-Ps-Out

1SNA 684 334 R2400

In-Out

1SNA 684 202 R0100

In-Ps-Out

1SNA 684 236 R2200

In-Out

1SNA 684 212 R2200

In-Out

1SNA 684 232 R2600

RS 485

In-Ps-Out

1SNA 684 246 R0400

RS 232 / RS 485

In-Ps-Out

1SNA 684 252 R0200

RS 422/RS485

RS 232 - EIA-232 / V.24 / V.28
–– Point-to-point connection
–– Max. 15 m transmission distance
–– Rate up to 19.2 kbit/s
–– Full-duplex
RS 422 - EIA-422 / V.11
–– Point-to-point connection
–– (1 Transmitter - 10 Receivers)
–– Differential voltage transmission
–– Full-duplex
–– Up to 1200 m/ 10 Mbit/s
–– Good EMC characteristics
Current loop(TTY)
–– Point-to-point / multi-point connection
–– Active or passive current loop
–– Full-duplex
–– Up to 1200 m/19.2 kBit/s
–– Good EMC characteristics

RS 485 - ISO/IEC/EIA-485
– – Multi-point connection up to 32 units
– – Differential voltage transmission
– – Half-duplex on 1 pair
– – Full-duplex on 2 pairs
– – Up to 1200 m / 10 Mbit/s
– – Good EMC characteristics
Optical fiber interface
– – Point-to-point connection
– – Full-duplex
– – From 40 m up to 4km transmission distance
– – Excellent EMC characteristics
Ethernet Interface
– – Point to point connexion or multipoint connection.
– – Up to 100 m using CAT5 cable without Hub or Switch
– – 10/100 Mbit/s
– – Good EMC characteristics

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/36

4

Serial data converters
Ordering details

2CDC 281 003 F0013

Ordering details

ILPH RS 232-RS 485 / Ethernet

Type

Order code

Serial data converter e-ILPH

ILPH RS 232-RS 485 /
Ethernet

1SNA684252R0200

0.12
(0.265)

Serial link interface without electrical isolation

ILPH RS 232 /
RS 422-485

1SNA684231R2500

0.1
(0.220)

Serial link interface with electrical isolation

ILPH RS 232 /
RS 422-485

1SNA684233R2700

0.1
(0.220)

ILPH RS 232 / RS 422485 (24-48 V DC
power supply)

1SNA684333R2300

ILPH RS 232 / RS 422485 (115-230 V AC
power supply)

1SNA684334R2400

ILPH RS 232 / RS 232
(24-48 V DC power supply)

1SNA684234R2000

ILPH RS 232 / RS 232
(115-230 V AC power
supply)

1SNA684234R0200

Serial link interface with electrical isolation

ILPH RS 422 - 485 / RS
422 - 485 (24 V DC power
supply)

1SNA684212R2200

0.1
(0.220)

Serial link interface 3 way electrical isolation

ILPH RS 232 / FO-S
(24...42 V AC/DC power
supply)

1SNA684236R2200

0.15
(0.331)

Serial link interface 3 way electrical isolation

ILPH RS 485 / FO-S
(24...42 V AC/DC power
supply)

1SNA684246R0400

0.15
(0.331)

Serial link interface with electrical isoaltion

ILPH BdC /RS 422 - 485
(24 V DC power supply)

1SNA684232R2600

0.1
(0.220)

Serial link interface with electrical isolation

ILPH RS 232 (24 V DC
power supply)

1SNA684202R0100

0.1
(0.220)

Serial link interface 3 way electrical isolation

Serial link interface 3 way electrical isolation

2CDC 281 001 S0013

4

Description

ILPH RS 232 / RS 422-485

4/37 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Price

Weight
(1 pce)
kg (lb)

0.1
(0.220)

0.1
(0.220)

Serial data converters
Technical information
ILPH RS 232 - 485 Ethernet
1SNA684252R0200
SubD9
connector
pin 2 = RX
pin 3 = TX
pin 5 = GND
pin 7 = RTS

GND
RX

TX
K

L

3

4
4

5

6

7

K

3

8

TX

2

GND

1

PW RX
R

ON

M
L

G

2

H

1
ON

J

K

L

M

M

LIN

D
D

ern

A

E

D

ACTIVITY

SPEED

et

e-ILPH

K

TX

RX
Eth

D

center of rail
E

B2-

A

4

B1+

+24V
0V

24V

ILPH RS 232 / RS 422-485 (without isolation)
1SNA684231R2500
RS 422 - RS 485
SERIAL LINK (2 wires)

RS 422 - RS 485
SERIAL LINK (4 wires)
Product RS 232

Product RS 232

Connector J1

Connector J1
24 V DC
power supply
24 V DC
power supply
Product RS 422-RS 485

Product RS 422-RS 485

*CAUTION:
When the RTS Signal is not activated,
M terminal (RxD ILPH) has to be
connected to L terminal (CTRL IN).

RS 485 LINK ON ONE PAIR
R
without
isolation

E

R ON/
OFF

Jumper
R in
position
RON/OFF

E ON/
OFF

Jumper
E in
position
EON/OFF

The Receiver and the Transmitter are activated
alternately (never at the same time) depending on
the status of the CTRL IN signal.

POLARIZATION OF THE
RS 422 - RS 485 LINE

Connection by 1 wire

P+ (J1.1) with 5V
(J1.4)

Connection by 1 wire

P- (J1.2) with 0V
(J1.3)

RS 485 LINK ON TWO PAIRS

0 logic
(+3V m U m +25V)
1 logic
(-25V m U m -3V)
High impedance

R ON

ACTION ON RS 485

Transmitter active /
Receiver inactive
Transmitter inactive /
Receiver active
Transmitter inactive /
Receiver active

NOTE : For RS 232 products running the RTS
(REQUEST TO SEND) signal, connect RTS to CTRL
IN. Otherwise, connect M (RxD ILPH) to L (CTRL
IN).

without
isolation

E

E ON/
OFF

Configuration of the jumper
Rt

R

E

RS422 LINK ON TWO PAIRS

The line must always be polarized.
The ILPH is used to polarize the reception channel :

R
CTRL IN STATUS

** CAUTION :
To be connected to 2 wired RS 485
only (not possible for 4 wired RS 422).
When the RTS Signal is not activated,
M terminal (RxD ILPH) has to be
connected to L terminal (CTRL IN).

Jumper
R in
position
RON
Jumper
E in
position
EON/OFF

Receiver permanently active
Transmitter controlled by the signal CTRL IN (see
table for Transmitter operation as a function of
CTRL IN)

without
isolation

R

R ON

Jumper
R in
position
RON

E

E ON

Jumper
E in
position
EON

The Transmitter and Receiver are both permanently
active.

ADAPTING THE RS 422 - RS 485 LINE
The line must always be adapted to the level of
the reception channel of each subscriber forming
the end of the bus. The ILPH is used to adapt the
reception channel by setting the jumper Rt correctly
:

* Line adaptation, Rt = 120 Ω
(general case )
Rt

* Line adaptation, Rt = 220 Ω
* No line adaptation, Rt = ∝

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/38

Serial data converters
Technical information
ILPH RS 232 / RS 422-485 (with isolation)
1SNA684233R2700
RS 422 - RS 485
WIRE SERIAL LINKS

RS 422 - RS 485
WIRE SERIAL LINKS
RS 232 product

RS 232 product

4
Connector J1
Connector J1

24 V DC
power supply

24 V DC
power supply

RS 422-RS 485
product

RS 422-RS 485
product

* CAUTION :
If the RTS signal is not generated,
connect M (RxD ILPH) to L (CTRL IN).

RS 485 LINK ON ONE PAIR
R

Isolated

E

R ON/
OFF

E ON/
OFF

Jumper
R in
position
RON/OFF
Jumper
E in
position
EON/OFF

The Receiver and the Transmitter are activated
alternately (never at the same time) depending on
the status of the CTRL IN signal.
CTRL IN STATUS

ACTION ON RS 485

1 logic
(-25 V m U m -3V)
High impedance

Transmitter inactive /
Receiver active
Transmitter inactive /
Receiver active

0 logic
(+3 V m U m +25 V)

Transmitter active /
Receiver inactive

NOTE : For RS 232 products running the RTS
(REQUEST TO SEND) signal, connect RTS to CTRL
IN. Otherwise, connect M (RxD I LPH) to L (CTRL
IN).

Rt

** CAUTION :
Only to be connected for RS 485 two
pairs (of no use for RS 422 two pairs).
If the RTS signal is not generated,
connect M (RxD ILPH) to L (CTRL IN).

POLARIZATION OF THE
RS 422 - RS 485 LINE

Connection by 1 wire

P+ (J1.1) with 5V
(J1.4)

Connection by 1 wire

P- (J1.2) with 0V
(J1.3)

RS 485 LINK ON TWO PAIRS
R

R ON

Jumper R in
position RON

E

E ON/
OFF

Jumper E in
position EON/
OFF

Receiver permanently active
Transmitter controlled by the signal CTRL IN (see
table for Transmitter operation as a function of
CTRL IN)

4/39 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

R

E

RS422 LINK ON TWO PAIRS

The line must always be polarized.
The ILPH is used to polarize the reception channel :

Isolated

Configuration of the jumper

Isolated

R

R ON

Jumper R in
position RON

E

E ON

Jumper E in
position EON

The Transmitter and Receiver are both permanently
active.

ADAPTING THE RS 422 - RS 485 LINE
The line must always be adapted to the level of t
he reception channel of each subscriber forming
the end of the bus. The ILPH is used to adapt the
reception channel by setting the jumper
Rt correctly :

* Line adaptation, Rt = 120 Ω
(general case )
Rt

* Line adaptation, Rt = 220 Ω
* No line adaptation, Rt = ∝

Serial data converters
Technical information
ILPH RS 232 / RS 422 - 485 (eletrical isolated)
1SNA684333R2300, 1SNA684334R2400
RS 422 - RS 485
2 WIRE SERIAL LINK

RS 422 - RS 485
4 WIRE SERIAL LINKS
Product RS 232

Product RS 232

4

Connector J1

Connector J1

Power
supply

Power
supply
Product
RS 422 - RS 485

Product
RS 422 - RS 485

**CAUTION :

*CAUTION :
SW2
SW1

Configuration of the jumper

8 7 6 5 43 2 1

OFF ON

SW1

OFF
ON

SW2

21

When the RTS signal is not generated, set SW2-1
in position ON.

Only to be connected for RS 485 two pairs (of no
use for RS 422 two pairs).
If the RTS signal is not generated, set SW2-1 in
position ON.

RS 485 LINK ON ONE PAIR

RS 422 LINK ON TWO PAIRS

Set SW1-1, SW1-3, SW1-6, SW1-7 and SW1-8
to position ON. The receiver and the transmitter
are activated alternately (never at the same time),
depending on the status of the CTRL IN signal.

Set SW1-1, SW1-3, SW1-7 and SW1-8 in position
OFF.
Set SW1-6 in position ON.
Transmitter and receiver are both permanently
active.

CTRL IN STATUS
0 Logic
(3 V m U m + 25 V)
1 Logic
(-25 V m U m -3 V)
High impedance

Action on RS 485
Transmitter active /
Receiver inactive
Transmitter inactive /
Receiver active
Transmitter inactive /
Receiver active

CAUTION : For RS 232 products running the RTS
signal (REQUEST TO SEND), connect RTS to CTRL
IN.
Otherwise, set SW2-1 to position ON.

RS 485 LINK ON TWO PAIRS
Set SW1-1, SW1-3, SW1-7 in position OFF.
Set SW1-6, SW1-8 in position ON.
The receiver is permanently active.
The transmitter is controlled by the signal CTRL IN
(see table for transmitter operation as a fonction of
CTRL IN).

POLARIZATION OF THE RS 422 - RS
485 LINE
The line must always be polarized.
The ILPH is used to polarize the reception channel.
Set SW1-4 and SW1-5 in position ON.

ADAPTING THE RS 422 - RS 485 LINE
The line must always be adapted to the level of the
reception channel of each subscriber forming the
end of the bus.
The ILPH is used to adapt the reception channel by
setting the jumper SW1-2 correctly :
SW1-2 in position ON ⇒ line adaptation
Rt = 120 Ω (standard)
SW1-2 in position OFF ⇒ no line adaptation
Rt = ∝

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/40

Serial data converters
Technical information
ILPH RS 232 / RS 232 (eletrical isolated)
1SNA684234R2000, 1SNA684244R0200

Terminal equipment for ETTD (DTE)
data processing

Connection not advised
according to EIA/TIA
232E standard

(to be connected)

4

center of rail

or
Connection not advised
according to EIA/TIA 232E
standard

Data transmission end
equipment ETCD (DCE)

ILPH RS 232 / FO
1SNA684236R2200

(L)
(M) TxD

RxD
OV (K)

(J
Shielding

H
G)

FO Sending

(B)

←

→
FO Receiving

(F)

(A)
Shielding

(D)

OV
(E)

(C)

~
~+

4/41 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Serial data converters
Technical information
ILPH RS 485 / FO
1SNA684246R0400

D-D+
OV

Polarization configuration
of the micro-switch
SW 2
1 2 3

4

5 6

OFF

Shielding

4

FO Sending

←

→
FO Receiving

Baud rate:
SW1 DIP switch configuration
Baudrate bit/s

SW 1
1
2
M
M
M M
M
M
M
M M
M

1500000
500000
375000
187500
136000
115200
93750
75000
57600
38400
19200 M
9600
4800
300

M
M

Shielding
OV

3
M

4
M

M
M
M
M
M
M
M
M
M

5
M
M
M

M
M
M

M

6

7

8

~
~
+

Baud rate configuration of
the micro-switch
SW 1

M
M
M
M

M
M

M
M
M
M

M

M

M

4

5

6

M

M
M
M
M

M
M

1 2 3

4

5 6 7 8

OFF

M
M
M
M
M

M
M

End-of-line resistor, polarization:
SW2 DIP switch configuration
Baudrate bit/s

SW 2
1
2
Polarization
M
EOL 60 ohm
EOL 120 ohm
EOL 180 ohm
EOL 240 ohm
EOL indefinite

3
M

M

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/42

Serial data converters
Technical information
ILPH RS 422 - 485 / RS 422 / - 485
1SNA684212R2200
RS 422 - RS 485
4 wire serial link

RS 422 - RS 485
2 wire serial link

Channel 1 configuration
of the micro-switch
INT 4
1 2 3

4

Channel 1
configuration
of the microswitch

1

OFF

INT 4

1 2 3 4

OFF

4
Connector J1

Connector J1

BAUD RATE
FULL DUPLEX
500 Kb/s
187.5 Kb/s
93.75 Kb/s
38.4 Kb/s
19.2 Kb/s
9.6 Kb/s
4.8 Kb/s
2.4 Kb/s
1.2 Kb/s

INT 1 INT 2 INT 3 INT 4
1234 1234 1234
123456
0000 0000 XXX1 XXX101
1111
1111 XXX0 XXX000
1111
1110 XXX0 XXX000
1111
1100 XXX0 XXX000
1111
1000 XXX0 XXX000
1111 0000 XXX0 XXX000
1110 0000 XXX0 XXX000
1100 0000 XXX0 XXX000
1000 0000 XXX0 XXX000
0000 0000 XXX0 XXX000

Nu = not used
X = zero

24 V DC
power supply

24 V DC
power supply

Caution :
The transmission
channels of both RS
422 - RS 485 serial link
interfaces always have
to be independently
polarized.

1 = contact closed
0 = contact open (aus)
(off)

center of rail

Baud rate configuration of
the micro-switch
INT 1

RS 422 - RS 485 DRIVERS CONTROL
The RS 422 - RS 485 Drivers Control (transmitters
and receivers) makes the ILPH easy to use. The
control of the 2 channels is completely automatic ;
you only have to configure the baud rate needed.
The minimum turn off delay is about 1.5 character/
time from 27 µs to 10 ms depending on the baud
rate selected.

POLARIZATION OF THE RS 422 RS 485 CONNECTIONS
The connections must always be polarized. The
ILPH is used to polarize the reception channels:
INT 3
1

2

3

4

INT 3.1
INT 3.2

OFF

"ON", polarizes the
reception channel Rx2

INT 4
1

OFF

2

3

4

ADAPTING THE RS 422 RS 485 CONNECTIONS

6

INT 4.1
INT 4.2

"ON", polarizes the
reception channel Rx1

OFF

The connections must always be adjusted to the
level of the reception channel of each subscriber
forming the end of the bus. The ILPH is used to
adjust the reception channel by setting the microswitch INT 3.3 and INT 4.3.
INT 4

INT 3
1

2

3

4

1

OFF

2

3

4

OFF

5

6

INT 3.3 and INT
4.3 "ON" 120 Ω
set adjustment

BAUD RATE
By using the 8 micro-switches inside the box.
INT 1
1

OFF
5

1 2 3

2

3

INT 2
4

1

2

3

4

OFF

Permits to define up to 8 transmission speeds and
to select the Full Duplex operation mode (RS 422
/ RS 422) in addition with the INT 3.4 INT 4.4 and
INT 4.5 micro switches.

4/43 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

INT 2
4

1 2 3 4

OFF

Serial data converters
Technical information
ILPH CL / RS 422 - 485
1SNA684232R2600
LINE AMPLIFIER CONFIGURATION
Configuration of amplifiers of the RS 422 - RS 485 (Receiver,
Transmitter) line provides greater flexibility of use.The various
configurations can be selected using the 2 jumpers (R INT2, E
INT1) located inside the box.

RS 485 LINK ON ONE PAIR
R

INT2

E

INT3

R ON/OFF Jumper R in position R ON/OFF
E ON/OFF Jumper E in position E ON/OFF

The Receiver and the Transmitter are activated alternately (never
at the same time) depending on the status of the Current Loop
Reception signal.

RS 485 LINK ON TWO PAIRS
INT2 R ON

R

INT3 E

E

ON / OFF

R ON Jumper R in position R ON
E ON/OFF Jumper E in position E ON/OFF

4
RS 422 - RS 485 2 wire serial link

RS 422 - RS 485
4 wire serial link
Current Loop

Current Loop

Receiver permanently active. Transmitter controlled by the Current
Loop Reception signal.

RS 422 LINK ON TWO PAIRS
R

INT2 R ON

E

INT3 E ON

R ON
E ON

Jumper R in position R ON
Jumper E in position E ON
Connector J1

Connector J1

The Receiver and the Transmitter are both permanently active.
24 V DC
power supply

POLARIZATION OF THE RS 422 - RS 485 LINE

Note :
The TxD channel of the RS 422
- RS 485 link must be polarized
independently too.

The line must always be polarized. The ILPH is used to polarize
the reception channel :
Connection by 1 wire P+ (J1.1) with 5 Viso (J1.4)
Connection by 1 wire P- (J1.2) with 0 Viso (J1.3)

ADAPTING THE RS 422 - RS 485 LINE
The line must always be adapted to the level of the reception
channel of each subscriber forming the end of the bus. The ILPH
is used to adapt the reception channel by setting the jumper Rt
correctly :
Rt

INT1

Rt

INT1

ON

S1 S2 S3 S4

OFF

Legend

on
off

24 V DC
power supply

CONNECTIONS
Example of connection with a CL
(current Loop) product, Transmission
(TxD) in active mode and Reception
(RxD) in passive mode.
Then, the ILPH must be configured
and connected Reception (RxD) in
passive mode and Transmission (TxD)
in active mode.
Note : For any other configuration, see
schematic diagram or front sticker of
the product.

* Line adaptation, Rt = 120 Ω (Standard)
* No line adaptation, Rt = ∞

Transmission (TxD) active
Transmission(TxD) passive
Reception (RxD) active
Reception (RxD) passive
4...20 mA Signal
0...20 mA Signal
Signal logic 1 = 20 mA
Signal logic 0 = 20 mA

Configuration
of the jumper
Rt

E

R

INT1 INT2 INT3

Polarization

Configuration
of the microswitches
1 2 3 4

INT4

POLARIZATION
The polarization can be configured using the INT4 jumper.
INT4

INT4

Protection ON

Protection OFF, used if power
supply at minimum value (21.6 V).

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/44

Serial data converters
Technical information
ILPH RS 232 / CL
1SNA684202R0100

CONFIGURATION
The various configurations can be selected using the 4 micro-switches located
inside the box.

OPERATING MODE ACTIVE OR PASSIVE
The Current Loop's Transmission and Reception can be independently in active
or passive mode.
Select operating mode using S1 and S2.
S1 S2 S3 S4
			
ON
			

4

OFF

CONNECTIONS
Example of connection with
a CL (Current Loop) product,
Transmission (TxD) in active
mode and Reception (RxD)
in passive mode. Then, the
ILPH must be configured and
connected Reception (RxD) in
passive mode and Transmission
(TxD) in active mode.

24 V DC
power supply

CAUTION: For any other
configuration, see schematic
diagram or front sticker of the
product.
Current loop

S1
S2

Transmission(TxD) ON = Active / OFF = Passive
Reception (RxD) ON = Active / OFF = Passive

SIGNAL LEVEL
Select signal level 4-20 mA or 0-20 mA. This selection is made using microswitch S3
ON

S1 S2 S3 S4

			

S3 ON = 4-20 mA / OFF = 0-20 mA

OFF

Caution : It is not possible to select a 4-20 mA signal when the Reception is in
active mode.

LOGIC LEVEL
Configuration:
			

Positive logic
or negative logic

(0 Logic = 20 mA)
(1 Logic = 20 mA)

using micro-switch S4
S1 S2 S3 S4

ON
			
OFF

ILPH RS 232 / CL

Configuration of the
micro-switches
S1 S2 S3 S4

center of rail

4/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

S4 ON = (1 = 20 mA) / OFF = (0 = 20 mA)

Serial data converters
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 - 485 / Ethernet
Power supply 1
Voltage
Voltage tolerance
Consumption
Connections
Power supply 2
Voltage
Voltage tolerance
Consumption
Connections
Serial link 1: RS 232
Overvoltage protection
Baud rate / Transmission
distance
Connections
Serial link 2: RS 485
Voltage
Line polarization
End line resistance
Baud rate / Transmission distance
Connections
Ethernet link
Overvoltage protection
Baud rate / Transmission
distance
Connections
Traffic indication
Voltage
Status of signal
EMC behavior
Electrostatic discharge
Radiated electromagnetic field
Burst
Surge
Electromagnetic compatibility
Other characteristics
Electrical isolation between serial link / power supply /
Ethernet link
Configuration of the operating mode
Operating temperature
Storage temperature
Mounting
DIN rail fixing (EN 50002)
Wire size
Dimensions (WxDxH)
Weight

10...34 V DC, 10...24 V AC
-10%, +10%
2 W max
coding screw removable connector 0 to 2.5 mm² (22-14 AWG)
10...34 V DC
-10%, +10%
2 W max
screw connector (AWG 20)
EIA RS 232
integrated
max. 115.2 kbits/s / max. 15 m
2.5 mm² screw connector (AWG 20) or male SubD 9 points
EIA RS 485
integrated
integrated
integrated
max. 115.2 kbits/s / max. 1200 m
coding screw removable connector 0 to 2.5 mm² (22-14 AWG)
integrated
10-100 Mbits/s / max. 100 m without Hub or Switch with CAT5 cable
RJ45 connector
1 yellow LED
3 green LED (RxD, TxD, LINK), 2 amber or green LED (Speed, Activity)
EN
EN
EN
EN
EN

61000-4-2
61000-4-3
61000-4-4
61000-4-5
55022

750 VDC / 1500 VAC
using internal switches or/and software (TELNET or HYPERTERMINAL)
0°C ... +60°C
-20°C ... +70°C
any required
snap-on mounting
2.5 mm² / stranded with ferrule, 4 mm² solid
94 x 22.5 x 100 mm
120 g

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/46

4

Serial data converters
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / RS 422 - 485 (without isolation)

4

Power supply
Voltage
Voltage tolerance
Supply current
Connections
Serial link 1: RS 232
Overvoltage protection
Baud rate / Transmission
distance
Connections
Serial link 2: RS 422-485
Overvoltage protection
Baud rate / Transmission
distance
Connections
Traffic indication
Voltage
Connections
EMC behavior
Electrostatic discharge
Radiated electromagnetic field
Burst
Electromagnetic compatibility
Other characteristics
Electrical isolation between serial link / power supply /
Ethernet link
Configuration of the operating
mode
Operating temperature
Storage temperature
Mounting
DIN rail fixing (EN 50002)
Wire size
Dimensions (WxDxH)
Weight

polarized
24 V DC
8.5...28 V DC
100 mA max
removable screw connectors (AWG 20)
EIA RS 232 C / CCITT V24 V28
integrated (transil 8 kV 1.2/50 µs)
max. 38.4 kbits/s / max. 1200 m
2.5 mm² screw connectors (AWG 20)
EIA RS 485 and EIA RS 422 / CCITT V11
integrated (transil 8 kV 1.2/50 µs)
max. 38.4 kbits / max. 1200 m
2.5 mm² screw connectors (AWG 20)
1 yellow LED
2 green LED (RxD, TxD)
EN
EN
EN
EN

61000-4-2 level 3 6/8 kV
61000-4-3 level 310 V/m
61000-4-4 level 3 1 kV
55022 class B

no
using internal jumper
0°C ... +50°C
-25°C ... +80°C
any required
snap-on mounting
2.5 mm² / stranded with ferrule, 4 mm² solid
88 x 22.5 x 100 mm
100 g

4/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Serial data converters
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / RS 422 - 485 (isolated)
Power supply
Voltage
Voltage tolerance
Supply current
Connections
Serial link 1: RS 232
Overvoltage protection
Baud rate / Transmission
distance
Connections
Serial link 2: RS 422-485
Overvoltage protection
Baud rate / Transmission
distance
Connections
Traffic indication
Voltage
Connections
EMC behavior
Electrostatic discharge
Radiated electromagnetic field
Burst
Electromagnetic compatibility
Other characteristics
Electrical isolation between serial link / power supply /
Ethernet link
Configuration of the operating
mode
Operating temperature
Storage temperature
Mounting
DIN rail fixing (EN 50002)
Wire size
Dimensions (WxDxH)
Weight

polarized
24 V DC
8.5...28 V DC
100 mA max
Removable screw connectors (Omniconnect)
EIA RS 232 C / CCITT V24 V28
integrated (transil 8 kV 1.2/50µs)
max. 38.4 kbits/s / max. 15 m
2.5 mm² screw connectors (AWG 20)
EIA RS 485 and EIA RS 422 / CCITT V11
integrated (transil 8 kV 1.2/50 µs)
max. 38.4 kbits / max. 1200 m
2.5 mm² screw connectors (AWG 20)
1 yellow LED
3 green LED (RxD, TxD and CTRL-IN)
EN
EN
EN
EN

61000-4-2 level 3 6/8 kV
61000-4-3 level 310 V/m
61000-4-4 level 3 1 kV
55022 class B

500 V DC
using internal jumper
0°C ... +50°C
-25°C ... +80°C
any required
snap-on mounting
2.5 mm² / stranded with ferrule, 4 mm² solid
88 x 22.5 x 100 mm
100 g

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/48

4

Serial data converters
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / RS 422 - 485 (3 way electrical isolated)

4

Power supply
Voltage
Voltage tolerance
Supply current
Supply power
Connections
Serial link 1: RS 232
Overvoltage protection
Baud rate / Transmission
distance
Connections
Serial link 2: RS 422-485
Overvoltage protection
Baud rate / Transmission
distance
Connections
Traffic indication
Voltage
Connections
EMC behavior
Electrostatic discharge
Radiated electromagnetic field
Burst
Electromagnetic compatibility
Other characteristics
Electrical isolation between RS 232 / Power supply /
RSS 422-RS 485
Configuration of the operating
mode
Operating temperature
Storage temperature
Mounting
DIN rail fixing (EN 50002)
Wire size
Dimensions (WxDxH)
Weight

Polarization for DC model
24...48 V DC
115...230 V AC (50/60 Hz)
-15% ... +20%
-15% ... +15%
24 V DC<110 mA, 48 V DC<55 mA, 115 V AC<40 mA, 230 V DC<26 mA
~3W
~ 3 VA
Removable screw connector (Omniconnect)
EA / TIA RS 232 new revision / CCITT V24 V28
integrated (transil 8 kV 1.2/50 μs)
max. 19,2 kbits/s / max. 15 m / 2500 pF
2.5 mm² screw (AWG 20)
EIA / TIA RS 232 new revision / CCITT V24 V28
integrated (transil 8 kV 1.2/50μs)
max. 19.2 kbits/s / max. 15 m
2.5 mm² screw (AWG 20)
1 yellow LED
4 green LED (RxD, RxC/D, TxD, TxC/D)
EN
EN
EN
EN

61000-4-2 level 3 6/8 kV
61000-4-3 level 3 10 V/m
61000-4-4 level 3 1 kV
55022 class B

1,5 kV
No
0°C ... +50°C
-25°C ... +80°C
any required
snap-on mounting
2.5 mm² / stranded with ferrule, 4 mm² solid
88 x 22,5 x 100 mm
100 g

4/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Serial data converters
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / RS 232
Power supply
Voltage
Voltage tolerance
Supply current
Supply power
Connections
Interface 1: RS 232
Overvoltage protection
Transmission capacity / Transmission distance
Connections
Interface 2: RS 232
Overvoltage protection
Transmission capacity / Transmission distance
Connections
Traffic indication
Voltage
Connections
EMC behavior
Electrostatic discharge
Radiated electromagnetic field
Burst
Electromagnetic compatibility
Other characteristics
Electrical isolation between serial link / power supply /
Ethernet link
Configuration of the operating
mode
Operating temperature
Storage temperature
Mounting
DIN rail fixing (EN 50002)
Wire size
Dimensions (WxDxH)
Weight

DC model polarized
24...48 V DC
115...230 V AC (50/60Hz)
-15%...+20%
-15%...+15%
24 V DC<155 mA;48 V DC<77 mA;110 V AC<40 mA;230 V DC<26 mA
~ 3.15 W
~ 3.15 VA
Removable screw connector (Omniconnect)
EIA / TIA RS 232 new revision / CCITT V24 V28
integrated (transil 8 kV 1.2/50 µs)
max. 19.2 kbits/s / max. 15 m / 2500 pF
2.5 mm² screw (AWG 20)
EIA / TIA RS 232 new revision / CCITT V24 V28
integrated (transil 8 kV 1.2/50 µs)
max. 19.2 kbits/s / max. 15 m
2.5 mm² screw (AWG 20)
1 yellow LED
4 green LED (RxD, RxC/D, TxD, TxC/D)
EN
EN
EN
EN

61000-4-2 level 3 6/8 kV
61000-4-3 level 3 10 V/m
61000-4-4 level 3 1 kV
55022 class B

1.5 kV
No
0°C ... +50°C
-25°C ... +80°C
any required
snap-on mounting
2.5 mm² / stranded with ferrule, 4 mm² solid
88 x 22.5 x 100 mm
100 g

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/50

4

Serial data converters
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 422 - 485 / RS 422 - 485

4

Power supply
Voltage
Voltage tolerance
Supply current
Connections
Interface 1: RS 422-485
Overvoltage protection
RS 485 data switching
Baud rate / Transmission
distance
Connections
Interface 2: RS 422-485
Overvoltage protection
RS 485 data switching
Baud rate / Transmission
distance
Connections
Traffic indication
Voltage
Connections
EMC behavior
Electrostatic discharge
Radiated electromagnetic field
Burst
Electromagnetic compatibility
Other characteristics
Electrical isolation between RS 232 / Power supply /
RSS 422-RS 485
Configuration of the operating
mode
Operating temperature
Storage temperature
Mounting
DIN rail fixing (EN 50002)
Wire size
Dimensions (WxDxH)
Weight

DC model polarized
24 V DC
+/-15%
120 mA max.
Removable screw connector (Omniconnect)
EIA / RS 485 and EIA RS 422 / CCITT V11
integrated (transil 8 kV 1.2/50 µs)
Time switching / Time delay transmission/reception 27 µs ...10 ms
from 1.2 to 500 kbits/s / max. 1200 m up to 38.4 kbit/s
2.5 mm² screw (AWG 20)
EIA / RS 485 and EIA RS 422 / CCITT V11
integrated (transil 8 kV 1.2/50 µs)
Time switching / Time delay transmission/reception 27 µs ...10 ms
from 1.2 to 500 kbits/s / max. 1200 m up to 38.4 kbit/s
2.5 mm² screw (AWG 20)
1 yellow LED
2 green LED (RxD, TxD, )
EN
EN
EN
EN

61000-4-2 level 3 6/8 kV
61000-4-3 level 3 10 V/m
61000-4-4 level 3 1 kV
55022 class B

500 V DC
using internal DIP switches
0°C ... +50°C
-25°C ... +80°C
any required
snap-on mounting
2.5 mm² / stranded with ferrule, 4 mm² solid
88 x 22.5 x 100 mm
100 g

4/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Serial data converters
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / FO
Power supplies
Supply voltage
Voltage tolerance
Connections
Interface 1: RS 232
Protection
Max. speed / max. distance
Connections
Fiber optic interface 2
Type of fiber / Connections
Wave length
Max. transmission power
Max. reception power
Max. speed
Max. distance
Status indication
Power supply / Data exchange
EMC behavior
Electrostatic discharge
Radiated electromagnetic field
Burst
Electromagnetic compatibility
Other characteristics
Electrical isolation input / power supply / output
Operating temperature
Storage temperature
Mounting
Connections
Dimensions (WxDxH)
Weight

24...42 V AC/DC (50/60 Hz)
110...240 V AC/DC (50/60 Hz)
-15% ... +10%
-15% ... +10%
Omniconnect pluggable connector
CCITT V.24/DIN 66020- CCITT V.28 DIN 66259-EIA 232 E
Integrated (transil 8 kV 1.2/50µs)
Max. 115.2 kbits/s / max. 15 m / 2500 pF
Omniconnect pluggable connector
DIN VDE 0888-1
Multimode fiber
Glass : ST connector; Plastic : FSMA screw connector
Glass : 820 nm; Plastic : 655 nm
Glass : 50/125 µm : -14.4 db/m; Glass : 62.5/125 µm : -14 db/m; Plastic : 980/1000 µm : -8
db/m
Glass : -28 db/m; Plastic : -20 db/m
Max. 115.2 kbits/s
Glass : 50/125 µm : 3 km; Glass : 62.5/125 µm : 4 km; Plastic : 980/1000 µm : 40 m
1 green LED / 2 green LEDs (RxD, TxD)
EN
EN
EN
EN

61000-4-2 Level 3 6/8 kV
61000-4-3 Level 3 10 V/m
61000-4-4 Level 3 1 kV
55022 Class B

2.5 kV
-20°C ... +60°C
-40°C ... +85°C
Onto DIN Rail (EN 50002)
14 AWG (2.5 mm²) fine stranded / 12 AWG (4 mm²) rigid
105 x 22.5 x 112 mm / 4.13 x 0.89 x 4.41"
150 g / 0.33 lb

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/52

4

Serial data converters
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 485 / FO
Power supplies
Supply voltage
Voltage tolerance
Connections
Interface 1: RS 232
Protection
Max. speed / max. distance
Connections
Fiber optic interface 2

4

Type of fiber / Connections
Wave length
Max. transmission power
Max. reception power
Max. speed
Max. distance
Status indication
Power supply / Data exchange
EMC behavior
Electrostatic discharge
Radiated electromagnetic field
Burst
Electromagnetic compatibility
Other characteristics
Electrical isolation input / power supply / output
Operating temperature
Storage temperature
Mounting
Connections
Dimensions (WxDxH)
Weight

24...42 V AC/DC (50/60 Hz)
110...240 V AC/DC (50/60 Hz)
-15% ... +10%
-15% ... +10%
Omniconnect pluggable connector
ISO / IEC 8482 / DIN 66 259-4; EIA 485
Integrated (transil 8 kV 1.2/50µs)
Max. 1.5 Mbits/s / max. 1200 m (38.4 kbit/s)
Omniconnect pluggable connector
DIN VDE 0888-1
Multimode fiber
Glass : ST connector; Plastic : FSMA screw connector
Glass : 820 nm; Plastic : 655 nm
Glass : 50/125 µm : -14.4 db/m; Glass : 62.5/125 µm : -14 db/m; Plastic : 980/1000 µm : -8
db/m
Glass : -28 db/m; Plastic : -20 db/m
Max. 1.5 Mbits/s
Glass : 50/125 µm : 3 km; Glass : 62.5/125 µm : 4 km; Plastic : 980/1000 µm : 40 m
1 green LED / 2 green LEDs (RxD, TxD)
EN
EN
EN
EN

61000-4-2 Level 3 6/8 kV
61000-4-3 Level 3 10 V/m
61000-4-4 Level 3 1 kV
55022 Class B

2.5 kV
-20°C ... +60°C
-40°C ... +85°C
Onto DIN Rail
14 AWG (2.5mm²) / fine stranded, 12 AWG (4 mm²) rigid
105 x 22.5 x 112 mm / 4.13 x 0.89 x 4.41"
150 g / 0.33 lb

4/53 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Serial data converters
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 422 - 485 (for current loop)
Power supply
Voltage
Voltage tolerance
Supply current
Connections
Interface 1: Current loop
Logic level
Baud rate / Transmission
distance
Connections
Serial link 2: RS 422/485
Overvoltage protection
Baud rate / Transmission
distance
Connections
Traffic indication
Voltage
Status of signal
EMC behavior
Electrostatic discharge
Radiated electromagnetic field
Burst
Electromagnetic compatibility
Other characteristics
Electrical isolation between input / output and power
supply / output
RS 422-485 power supply
Configuration of the operating
mode
Operating temperature
Storage temperature
Mounting
DIN rail fixing (EN 50002)
Wire size
Dimensions (WxDxH)
Weight

DC model polarized
24 V DC
+/-10%
120 mA max.
Removable screw connector (Omniconnect)
active/passive 0...20 mA / 4...20 mA, mode is settable
0 = 20 mA or 1 = 20 mA, settable
max. 38.4 kbit/s / max. 1200 m
2.5 mm² screw (AWG 20)
EIA RS 485 and EIA RS 422 / CCITT V 11
integrated (transil 8 kV 1.2/50 µs)
max. 38.4 kbit/s / max. 1200 m
2.5 mm² screw (AWG 20)
1 yellow LED
2 green LED (RxD, TxD)
EN
EN
EN
EN

61000-4-2 level 2 4/4 kV
61000-4-3 level 3 10 V/m
61000-4-4 level 1 0.5 kV
55022 class B

depending on Current Loop (active/passive); 500 V DC (active) / 2000 V DC (passive)
500 V DC
using internal DIP switches
0°C ... +50°C
-25°C ... +80°C
any required
snap-on mounting
2.5 mm² / stranded with ferrule, 4 mm² solid
88 x 22.5 x 100 mm
100 g

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/54

4

Serial data converters
Technical data
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / CL

4

Power supply
Voltage
Voltage tolerance
Supply current
Connections
Serial link 2: RS 232
Logic level
Baud rate / Transmission
distance
Connections
BdC serial link 2: RS 422/485
Overvoltage protection
Baud rate / Transmission
distance
Connections
Traffic indication
Voltage
Status signal
EMC behavior
Electrostatic discharge
Radiated electromagnetic field
Burst
Electromagnetic compatibility
Other characteristics
Electrical isolation between Current loop / RS 232
Electrical isolation between Current loop / power
supply
Configuration of the operating
mode
Operating temperature
Storage temperature
Mounting
DIN rail fixing (EN 50002)
Wire size
Dimensions (WxDxH)
Weight

DC model polarized
24 V DC
+/-10%
120 mA max.
Removable screw connector (Omniconnect)
EIA RS 232 C / CCITT V 24 V 28
integrated (transil 8 kV 1.2/50 µs)
max. 38.4 kbit/s / max. 15 m
2.5 mm² screw (AWG 20)
active/passive 0...20 mA / 4...20 mA mode settable
0=20 mA or 1=20 mA settable
max. 38.4 kbit/s / max. 1200 m
2.5 mm² screw (AWG 20)
1 yellow LED
2 green LED (RxD, TxD)
EN
EN
EN
EN

61000-4-2 level 3 6/8 kV
61000-4-3 level 3 10 V/m
61000-4-4 level 3 1 kV
55022 class B

depending on current loop (active/passive) 500 V DC (active) / 2000 V DC (passive)
500 V DC (active) / 2000 V DC (passive)
using internal DIP switches
0°C ... +50°C
-25°C ... +80°C
any required
snap-on mounting
2.5 mm² / stranded with ferrule, 4 mm² solid
88 x 22.5 x 100 mm
100 g

4/55 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Serial data converters
Notes

4

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/56

Interface relays and optocouplers
Product group picture

5

5/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Interface relays and optocouplers
Table of contents

Interface Relays and Optocouplers
Pluggable interface relays.................................................................. 5/3
Table of contents

5/4

Benefits and advantages

5/5

Approvals and marks

5/7

Ordering details - CR-S range

5/8

Ordering details - CR-P range

5/9

Ordering details - CR-M range

5/10

Ordering details CR-P/M functional modules

5/13

Ordering details - CR-U range

5/14

Ordering details - CR-U accessories

5/15

Technical data - CR-P, CR-M, CR-U

5/16

Technical data, load limit curves - CR-P, CR-M, CR-U

5/18

Technical data - Sockets for CR-P and CR-M

5/19

Technical data - Sockets for CR-U

5/20

Technical data - CR-S range

5/21

Technical data - CR-S range sockets

5/22

Load limit curves

5/23

Connection diagrams

5/24

Dimensional drawings

5/25

Interface relays and optocouplers R600 range.................................. 5/27
Table of contents

5/28

Benefits and advantages

5/29

Type designators

5/30

Interface relays R600 range. . ............................................................ 5/31
Benefits and advantages

5/31

Selection

5/33

Ordering details

5/35

Connection diagrams

5/37

Technical data

5/38

General technical data

5/43

Dimensional drawings, Load limit curves

5/44

Optocouplers R600 range................................................................ 5/45
Selection

5/45

Ordering details

5/47

Connection diagrams

5/48

Technical data

5/49

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/2

5

Pluggable interface relays
Product group picture

5

5/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Pluggable interface relays
Table of contents
Pluggable interface relays
Benefits and advantages

5/5

Approvals and marks

5/7

Ordering details - CR-S range

5/8

Ordering details - CR-P range

5/9

Ordering details - CR-M range

5/10

Ordering details CR-P/M functional modules

5/13

Ordering details - CR-U range

5/14

Ordering details - CR-U accessories

5/15

Technical data - CR-P, CR-M, CR-U

5/16

Technical data, load limit curves - CR-P, CR-M, CR-U

5/18

Technical data - Sockets for CR-P and CR-M

5/19

Technical data - Sockets for CR-U

5/20

Technical data - CR-S range

5/21

Technical data - CR-S range sockets

5/22

Load limit curves

5/23

Connection diagrams

5/24

Dimensional drawings

5/25

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/4

5

Pluggable interface relays
Benefits and advantages
Slim relays CR-S
–– Standard slim relays (5 mm), sockets (6.2 mm) and accessories
–– Combination of 9 different rated control supply voltages
possible:
–– DC versions: 5 V, 12 V, 24 V
–– AC/DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 230 V
–– Output: 1 c/o (SPDT) contacts (6 A), standard and goldplated contacts
–– Cadmium-free contact material
–– All sockets with LED
–– Screw and spring connection terminals
–– Jumper bar (red, black, blue), marker and separator available as accessories

5

Pluggable pcb relays CR-P
– – 9 different coil voltages
–– DC versions: 12 V, 24 V, 48 V, 110 V
–– AC versions: 24 V, 48 V, 110 V, 120 V, 230 V
– – Output contacts:
–– 1 c/o contact (16 A) or
–– 2 c/o contacts (8 A)
optionally equipped with gold contacts
– – Logical or standard sockets
– – Cadmium-free contact material
– – Width of socket: 15,5 mm
– – Pluggable function modules
–– Reverse polarity protection/Free wheeling diode
–– LED indication
–– RC elements
–– Overvoltage protection

1
1

2
2
3
4

3

4

4

6

7

4

1 Socket
2 Pluggable function module

1 Output contacts

3 Interface relay

2 Socket

4 Holder

3 Relay holder

4 Marker label

4 Marker
4 Interface relay
6 LED green: Control supply voltage applied

7 Control supply voltage

5/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Pluggable interface relays
Benefits and advantages
Pluggable miniature relays CR-M
–– 2 different coil voltages
– – DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V
– – AC versions: 24 V, 48 V, 110 V, 120 V, 230 V
–– Output contacts
– – 2 c/o contacts (12 A) or
– – 3 c/o contacts (10 A) or
– – 4 c/o contacts (6 A)
optionally equipped with gold contacts, LED and free
wheeling diode
–– Integrated test button for manual actuation and locking of
the output contacts (blue = DC, orange = AC) that can be
removed if necessary
–– With or without integrated LED
–– Logical or standard sockets
–– Cadmium-free contact material
–– Width on socket: 27 mm
–– Pluggable function modules
– – Reverse polarity protection/Free wheeling diode
– – LED indication
– – RC elements
– – Overvoltage protection

Pluggable universal relays CR-U
– – 12 different coil voltages
–– DC versions: 12 V, 24 V, 48 V, 110 V, 125 V, 220 V
–– AC versions: 24 V, 48 V, 60 V, 110 V, 120 V, 230 V
– – Output contacts
–– 2 c/o contacts (10 A) or
–– 3 c/o contacts (10 A)
– – Integrated test button for manual
actuation and locking of the output
contacts (blue = DC, orange = AC) that can be removed if
necessary
– – With or without integrated LED
– – Cadmium-free contact material
– – Width on socket: 38 mm
– – Pluggable function modules
–– Reverse polarity protection/Free wheeling diode
–– LED indication
–– RC elements
–– Overvoltage protection
–– Multifunction time module

1

1

2

2

3

3
4

4

1 Socket

1 Socket

2 Pluggable function module

2 Pluggable function module

3 Interface relay

3 Interface relay

4 Holder

4 Holder

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/6

5

Pluggable interface relays
Approvals and marks
Kind of connecting terminals
Kinds of sockets
Standard sockets - Position of connecting terminals:
Coil connection (A1-A2) on lower socket side, contact
connections (n/o and n/c contacts) on the lower and upper
socket side.
Logical sockets - Position of connecting terminals:
Coil connection (A1-A2) on lower socket side, all contact
connections (common contacts, n/o and n/c contacts) on
upper socket side.
Details see connection diagrams

Screw type

Spring type

Fork type

5

Approvals and marks

J

F

CAN/CSA C22.2 No.14

J

J

J

J

VDE

R

EAC

P

Lloyds Register

E

CCC
CQC

L

J

8)

J

J
J

J

J
J

J

4)

5)

J

J

J

J

J

J1)

J

J2)

J

J3)

J

J

J

J

J

J

J

J

J

J

J

J

J

J
J
J

CR-U

J

J

CR-P/M

J

J

CR-U..SM

CAN/CSA C22.2 No.14

J

CR-U..S
CR-U..E

cG

CR-M..SF

J

CR-M..L..
CR-M..SS

J

CR-PLC

J

CR-PLS
CR-PSS

ANSI/UL 508

CR-S
sockets

G

Approvals

Modules

CR-U

CR-M

Sockets

CR-P

Relays

CR-S

J existing
j pending

J

J 6)

J

J

J 6)

J

J

J

J

J

J

J

J

J

J

J

J

J
J

8)

J
J

J

RMRS

J

J

7)

J

7)

Marks
a
1)
2)
3)
4)
5)
6)
7)
8)

CE

J

J

J

J

except CR-PLSx
except CR-M...LC
except CR-U3E
except 125 V DC devices
only devices with 4 c/o contacts
except CR-U61D, CR-U61DV
except 60 V and 125 V devices
only relays and sockets with screw terminals

5/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Pluggable interface relays
Ordering details - CR-S range
Description

2CDC 291 005 F0014

The pluggable interface relays of the CR-S Range are used for electrical isolation, amplification
and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems
and the sensor / actuator level. The CR-S Range combines the flexibility of a modular system
and the ability of switching high currents on a small footprint thus can be used in applications
where space saving is essential.

CR-S

Ordering details - CR-S range pluggable interface relays
Rated control
supply voltage
5 V DC
12 V DC
24 V DC
48 V DC
60 V DC
5 V DC
12 V DC
24 V DC
48 V DC
60 V DC

Outputs

Contact
ratings

Type

1 c/o
(SPDT)
standard
contacts

250 V, 6 A

1 c/o
(SPDT)
gold plated
contacts

12 V,
250 mA
(3W)1)

CR-S005VDC1R
CR-S012VDC1R
CR-S024VDC1R
CR-S048VDC1R
CR-S060VDC1R
CR-S005VDC1RG
CR-S012VDC1RG
CR-S024VDC1RG
CR-S048VDC1RG
CR-S060VDC1RG

Order code

Price

1SVR405501R1010
1SVR405501R2010
1SVR405501R3010
1SVR405501R4010
1SVR405501R5010
1SVR405501R1020
1SVR405501R2020
1SVR405501R3020
1SVR405501R4020
1SVR405501R5020

Pkg Weight
(1 pce)
qty kg (lb)
10

0.005
(0.011)

10

0.005
(0.011)

5

Ordering details - CR-S range complete interface relays (relay + socket)
Rated control
supply voltage
RS, SS = screw connection type
RZ, SZ = spring connection type

Outputs

Contact
ratings

24 V AC/DC
110 V AC/DC

1 c/o
(SPDT)
standard
contacts

250 V,
6A

1 c/o
(SPDT)
gold plated
contacts

12 V,
250 mA
(3W)1)

230 V AC/DC
24 V AC/DC
110 V AC/DC
230 V AC/DC
1)

Type

Order code

CR-S024VADC1CRS
CR-S024VADC1CRZ
CR-S110VADC1CRS
CR-S110VADC1CRZ
CR-S230VADC1CRS
CR-S230VADC1CRZ
CR-S024VADC1CRGS
CR-S024VADC1CRGZ
CR-S110VADC1CRGS
CR-S110VADC1CRGZ
CR-S230VADC1CRGS
CR-S230VADC1CRGZ

1SVR405541R3110
1SVR405541R3210
1SVR405541R6110
1SVR405541R6210
1SVR405541R7110
1SVR405541R7210
1SVR405541R3120
1SVR405541R3220
1SVR405541R6120
1SVR405541R6220
1SVR405541R7120
1SVR405541R7220

Price

Pkg Weight
(1 pce)
qty kg (lb)

10

0.03
(0.066)

10

0.03
(0.066)

If specified maximum values exceeded, the gold plating is destroyed. The maximum values of the standard contacts are then
valid.

Ordering details - CR-S range sockets
Rated control
supply voltage
6-24 V DC
12-24 V AC/DC
48-60
V AC/DC
110-125
V AC/DC
220-240
V AC/DC

Connection type

Screw
Spring
Screw
Spring
Screw
Spring
Screw
Spring
Screw
Spring

Type

Order code

CR-S006/024VDC1SS
CR-S006/024VDC1SZ
CR-S012/024VADC1SS
CR-S012/024VADC1SZ
CR-S048/060VADC1SS
CR-S048/060VADC1SZ
CR-S110/125VADC1SS
CR-S110/125VADC1SZ
CR-S220/240VADC1SS
CR-S220/240VADC1SZ

1SVR405521R1100
1SVR405521R1200
1SVR405521R3100
1SVR405521R3200
1SVR405521R5100
1SVR405521R5200
1SVR405521R6100
1SVR405521R6200
1SVR405521R7100
1SVR405521R7200

Price

Pkg Weight
(1 pce)
qty kg (lb)

10

0.025
(0.055)

Ordering details - CR-S range accessories
Version

Type

Order code

Price

Pkg Weight
(1 pce)
qty kg (lb)

Jumper bar 20 pole, blue color
Jumper bar 20 pole, red color
Jumper bar 20 pole, black color

CR-SJB20-BLUE
CR-SJB20-RED
CR-SJB20-BLACK

1SVR405598R0700
1SVR405598R0800
1SVR405598R0900

10

0.008
(0.018)

Marker block

CR-SM

1SNB041391R0610

10

Separator

CR-SSEP

1SVR405599R0000

10

0.0036
(0.0079)
0.012
(0.026)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/8

Pluggable interface relays
Ordering details - CR-P range
Ordering details - CR-P range

2CDC 291 045 F0004

Rated control
supply voltage

Contact
ratings

Order code

CR-P012DC1
CR-P024DC1

1SVR405600R4000
1SVR405600R1000

48 V DC

CR-P048DC1

1SVR405600R6000

110 V DC

CR-P110DC1

1SVR405600R8000

CR-P024AC1

1SVR405600R0000

CR-P048AC1

1SVR405600R5000

120 V AC
230 V AC

CR-P110AC1
CR-P120AC1
CR-P230AC1

1SVR405600R7000
1SVR405600R2000
1SVR405600R3000

1 c/o (SPDT)

250 V, 16 A

110 V AC

5

Type

12 V DC
24 V DC

24 V AC
48 V AC

CR-P

Outputs

12 V DC

CR-P012DC2

1SVR405601R4000

24 V DC

CR-P024DC2

1SVR405601R1000

48 V DC

CR-P048DC2

1SVR405601R6000

110 V DC

CR-P110DC2

1SVR405601R8000

CR-P024AC2
CR-P048AC2
CR-P110AC2

1SVR405601R0000
1SVR405601R5000
1SVR405601R7000

120 V AC

CR-P120AC2

1SVR405601R2000

230 V AC

CR-P230AC2

1SVR405601R3000

24 V DC

CR-P024DC2

1SVR405606R1000

24 V AC

CR-P024AC2G

1SVR405606R0000

CR-P110AC2G

1SVR405606R7000

CR-P230AC2G

1SVR405606R3000

24 V AC
48 V AC
110 V AC

110 V AC

2 c/o (SPDT)

2 c/o (SPDT)
gold contact

250 V, 8 A

250 V, 8 A

230 V AC

Price

Pkg Weight
(1 pce)
qty

kg (lb)

10

0.014
(0.031)

10

0.014
(0.031)

10

0.014
(0.031)

CR-PLS

2CDC 291 006 F0011

Ordering details - Accessories
Version

Connection
terminal

Type

Order code

Logical socket with protective separation

2CDC 291 004 F0007

Pkg Weight
(1 pce)
qty

screw

CR-PLS

1SVR405650R0000

screw

CR-PLSx

1SVR405650R0100

Logical socket

CR-PJ

Price

Standard socket

kg (lb)
0.045
(0.099)

10

0.043
(0.095)

spring

CR-PLC

1SVR405650R0200

0.042
(0.093)

screw

CR-PSS

1SVR405650R1000

0.038
(0.084)

CR-PH

1SVR405659R0000

Plastic holder for socket

10

Jumper bar for sockets with screw connection

CR-PJ

1SVR405658R5000

Marker

CR-PM

1SVR405658R0000

5/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

10

0.002
(0.004)
0.018
(0.040)
0.0002
(0.0004)

Pluggable interface relays
Ordering details - CR-M range
Ordering details - CR-M range without LED

2CDC 291 002 F0015

Rated control
supply voltage

CR-M

Outputs

Contact
ratings

Type

Order code

12 V DC
24 V DC

CR-M012DC2
CR-M024DC2

1SVR405611R4000
1SVR405611R1000

48 V DC

CR-M048DC2

1SVR405611R6000

60 V DC

CR-M060DC2

1SVR405611R4200

110 V DC

CR-M110DC2

1SVR405611R8000

125 V DC

CR-M125DC2
250 V, 12 A
CR-M220DC2

1SVR405611R8200
1SVR405611R9000

CR-M024AC2
CR-M048AC2

1SVR405611R0000
1SVR405611R5000

CR-M110AC2

1SVR405611R7000

CR-M120AC2
CR-M230AC2

1SVR405611R2000
1SVR405611R3000

24 V DC

CR-M012DC3
CR-M024DC3

1SVR405612R4000
1SVR405612R1000

48 V DC

CR-M048DC3

1SVR405612R6000

60 V DC

CR-M060DC3

1SVR405612R4200

110 V DC

CR-M110DC3

1SVR405612R8000

125 V DC

CR-M125DC3
250 V, 10 A CR-M220DC3

1SVR405612R8200
1SVR405612R9000

48 V AC

CR-M024AC3
CR-M048AC3

1SVR405612R0000
1SVR405612R5000

60 V AC

CR-M060AC3

1SVR405612R5200

110 V AC
120 V AC

CR-M110AC3

1SVR405612R7000

CR-M120AC3
CR-M230AC3

1SVR405612R2000
1SVR405612R3000

24 V DC

CR-M012DC4
CR-M024DC4

1SVR405613R4000
1SVR405613R1000

48 V DC

CR-M048DC4

1SVR405613R6000

60 V DC

CR-M060DC4

1SVR405613R4200

110 V DC

CR-M110DC4

1SVR405613R8000

125 V DC

CR-M125DC4
CR-M220DC4

1SVR405613R8200
1SVR405613R9000

CR-M024AC4
CR-M048AC4

1SVR405613R0000
1SVR405613R5000

CR-M110AC4

1SVR405613R7000

CR-M120AC4
CR-M230AC4

1SVR405613R2000
1SVR405613R3000

220 V DC

2 c/o (SPDT)

24 V AC
48 V AC
110 V AC
120 V AC
230 V AC
12 V DC

220 V DC

3 c/o (SPDT)

24 V AC

230 V AC
12 V DC

220 V DC
24 V AC
48 V AC
110 V AC
120 V AC
230 V AC

4 c/o (SPDT)

250 V, 6 A

Price

Pkg Weight
(1 pce)
qty

kg (lb)

10

0.033
(0.073)

5

10

0.033
(0.073)

10

0.033
(0.073)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/10

Pluggable interface relays
Ordering details - CR-M range
Ordering details - CR-M range with LED
Rated control
supply voltage

Outputs

Contact
ratings

2CDC 291 002 F0015

12 V DC

5

Order code

24 V DC

CR-M012DC2L
CR-M024DC2L

1SVR405611R4100
1SVR405611R1100

48 V DC

CR-M048DC2L

1SVR405611R6100

60 V DC

CR-M060DC2L

1SVR405611R4300

110 V DC
125 V DC

CR-M110DC2L

1SVR405611R8100

CR-M125DC2L

1SVR405611R8300

CR-M220DC2L

1SVR405611R9100

48 V AC

CR-M024AC2L
CR-M048AC2L

1SVR405611R0100
1SVR405611R5100

110 V AC

CR-M110AC2L

1SVR405611R7100

120 V AC

CR-M120AC2L

1SVR405611R2100

230 V AC

CR-M230AC2L

1SVR405611R3100

12 V DC
24 V DC

CR-M012DC3L
CR-M024DC3L

1SVR405612R4100
1SVR405612R1100

48 V DC

CR-M048DC3L

1SVR405612R6100

60 V DC

CR-M060DC3L

1SVR405612R4300

110 V DC
125 V DC

CR-M110DC3L

1SVR405612R8100

CR-M125DC3L

1SVR405612R8300

CR-M220DC3L

1SVR405612R9100

48 V AC

CR-M024AC3L
CR-M048AC3L

1SVR405612R0100
1SVR405612R5100

110 V AC

CR-M110AC3L

1SVR405612R7100

120 V AC

CR-M120AC3L

1SVR405612R2100

230 V AC

CR-M230AC3L

1SVR405612R3100

12 V DC
24 V DC

CR-M012DC4L
CR-M024DC4L

1SVR405613R4100
1SVR405613R1100

48 V DC

CR-M048DC4L

1SVR405613R6100

60 V DC

CR-M060DC4L

1SVR405613R4300

110 V DC

CR-M110DC4L

1SVR405613R8100

125 V DC
220 V DC

CR-M125DC4L

1SVR405613R8300

CR-M220DC4L

1SVR405613R9100

48 V AC

CR-M024AC4L
CR-M048AC4L

1SVR405613R0100
1SVR405613R5100

110 V AC

CR-M110AC4L

1SVR405613R7100

120 V AC

CR-M120AC4L

1SVR405613R2100

230 V AC

CR-M230AC4L

1SVR405613R3100

220 V DC
CR-M

Type

2 c/o (SPDT)

250 V,
12 A

24 V AC

220 V DC

3 c/o (SPDT)

250 V,
10 A

24 V AC

4 c/o (SPDT)

250 V, 6 A

24 V AC

Price

Pkg Weight
(1 pce)
qty

kg (lb)

10

0.033
(0.073)

10

0.033
(0.073)

10

0.033
(0.073)

Ordering details - CR-M range with LED and free-wheeling diode
Rated control
supply voltage

24 V DC

Outputs

4 c/o (SPDT)

Contact
ratings

Type

250 V, 6 A CR-M024DC4LD

Order code

Price

1SVR405614R1100

Pkg Weight
(1 pce)
qty kg (lb)
10

0.033
(0.073)

Ordering details - CR-M range with gold contacts
Rated control
supply voltage

Outputs

Contact
ratings

Type

Order code

24 V DC

CR-M024DC4G

1SVR405618R1000

24 V AC

CR-M024AC4G
250 V, 6 A
CR-M110AC4G

1SVR405618R0000
1SVR405618R7000

CR-M230AC4G

1SVR405618R3000

110 V AC

4 c/o (SPDT),
gold contacts

230 V AC

5/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Price

Pkg Weight
(1 pce)
qty kg (lb)

10

0.033
(0.073)

Pluggable interface relays
Ordering details - CR-M range
Ordering details – CR-M range with gold contacts and LED
Rated control
supply voltage

Outputs

Contact
ratings

2CDC 291 002 F0015

12 V DC

Order code

24 V DC

CR-M012DC4LG
CR-M024DC4LG

1SVR405618R4100
1SVR405618R1100

48 V DC

CR-M048DC4LG

1SVR405618R6100

60 V DC

CR-M060DC4LG

1SVR405618R4300

110 V DC

CR-M110DC4LG

1SVR405618R8100

CR-M125DC4LG
CR-M220DC4LG

1SVR405618R8300
1SVR405618R9100

48 V AC

CR-M024AC4LG
CR-M048AC4LG

1SVR405618R0100
1SVR405618R5100

110 V AC

CR-M110AC4LG

1SVR405618R7100

120 V AC

CR-M120AC4LG
CR-M230AC4LG

1SVR405618R2100
1SVR405618R3100

125 V DC
220 V DC

CR-M

Type

24 V AC

4 c/o (SPDT)
with gold
contacts and
LED

250 V /
6A

230 V AC

Price

Pkg Weight
(1 pce)
qty

kg (lb)

10

0.033
(0.073)

10

0.033
(0.073)

Ordering details – CR-M range with gold contacts, LED and free-wheeling diode
Rated control
supply voltage

12 V DC
24 V DC

Outputs

Contact
ratings

4 c/o (SPDT)
with gold
contacts,
LED and
free-wheeling
diode

Type

CR-M012DC4LDG

Order code

Price

Pkg Weight
(1 pce)
qty

kg (lb)

10

0.033
(0.073)

1SVR405618R4400

CR-M024DC4LDG

1SVR405618R1400

Type

Order code

Ordering details - Accessories
Version

Connection
terminal

Price

Pkg Weight
(1 pce)

2CDC 291 009 F0011

qty
Logical socket for 2 c/o

CR-M2LS

1SVR405651R1100

CR-M3LS

1SVR405651R2100

CR-M4LS

1SVR405651R3100

CR-M2LC

1SVR405651R1200

CR-M4LC

1SVR405651R3200

CR-M2SS

1SVR405651R1000

CR-M3SS

1SVR405651R2000

CR-M4SS

1SVR405651R3000

CR-M2SF

1SVR405651R1300

CR-M4SF

1SVR405651R3300

Plastic holder

CR-MH

1SVR405659R1000

10

Metal holder

CR-MH1

1SVR405659R1100

10

Jumper bar for sockets with
screw connection

CR-MJ

1SVR405658R6000

10

Marker

CR-MM

1SVR405658R1000

10

Logical socket for 3 c/o

screw

Logical socket for 2/4 c/o

CR-M4SS

Logical socket for 2 c/o
Logical socket for 2/4 c/o

spring

CR-MJ

2CDC 291 005 F0007

Standard socket for 2 c/o
Standard socket for 3 c/o

screw

Standard socket for 2/4 c/o
Standard socket for 2 c/o
Standard socket for 2/4 c/o

fork type

10

10

10

10

kg (lb)
0.055
(0.121)
0.062
(0.137)
0.066
(0.146)
0.065
(0.143)
0.066
(0.146)
0.066
(0.146)
0.068
(0.150)
0.070
(0.154)
0.040
(0.088)
0.048
(0.106)
0.003
(0.007)
0.0005
(0.001)
0.029
(0.064)
0.0005
(0.001)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/12

5

Pluggable interface relays
Ordering details CR-P/M functional modules
Ordering details - CR-P/M range (all products stocked)

2CDC 291 005 S0011

Rated control
supply voltage

CR-P/M ...

Version

Type

Order code

Price

Pkg Weight
(1 pce)
qty kg (lb)

6-220 V DC

6-24 V DC
24-60 V DC
110-230 V DC

Diode Reverse
polarity
protection/free
wheeling diode
Diode and
LED - Reverse
polarity
protection/free
wheeling diode

A1+, A2-

CR-P/M 22

1SVR405651R0000

red, A1+, A2-

CR-P/M 42

1SVR405652R0000

green, A1+, A2- CR-P/M 42V
CR-P/M 42B
red, A1+, A2-

24-60 V AC/DC
110-230
V AC/DC

1SVR405652R4100

red, A1+, A2-

CR-P/M 42C

1SVR405652R9000

green, A1+, A2-

CR-P/M 42CV

1SVR405652R9100

CR-P/M 52B

1SVR405653R0000

CR-P/M 52D

1SVR405653R4000

CR-P/M 52C

1SVR405653R1000

CR-P/M 62

1SVR405654R0000

CR-P/M 62V

1SVR405654R1000

CR-P/M 62E

1SVR405654R4000

CR-P/M 62EV

1SVR405654R4100

CR-P/M 92

1SVR405654R0100

CR-P/M 92V

1SVR405654R1100

CR-P/M 62C

1SVR405655R0000

CR-P/M 62CV

1SVR405655R1000

CR-P/M 62D

1SVR405655R4000

Spark
quenching

6-24 V AC/DC

24-60 V AC/DC

Diode, LED and
reverse polarity
protection

110 V DC
110-230 V AC

6-24 V AC/DC

24-60 V AC/DC

Varistor and
LED
Overvoltage
protection

110 V DC
110-230 V AC
24 V AC
115 V AC
230 V AC

1SVR405652R4000

CR-P/M 42BV

6-24 V AC/DC

red, for DC A1+,
A2green, for DC
A1+, A2red, for DC A1+,
A2green, for DC
A1+, A2red, for DC A1+,
A2green, for DC
A1+, A2red, for DC A1+,
A2green, for DC
A1+, A2red, for DC A1+,
A2green, for DC
A1+, A2red, for DC A1+,
A2green, for DC
A1+, A2-

Overvoltage
protection

10

0.003
(0.007)

10

0.003
(0.007)

10

0.003
(0.007)

10

0.003
(0.007)

10

0.003
(0.007)

10

0.002
(0.004)

1SVR405652R1000

green, A1+, A2-

CR-P/M 62DV

1SVR405655R4100

CR-P/M 92C

1SVR405655R0100

CR-P/M 92CV

1SVR405655R1100

CR-P/M 72

1SVR405656R0000

CR-P/M 72A

1SVR405656R1000

CR-P/M 82

1SVR405656R2000

2CDC 292 013 F0005

2CDC 292 014 F0005

2CDC 292 015 F0005

Connection diagrams

CR-P/M 42, CR-P/M 42B, CR-P/M 52B, CR-P/M 52C
CR-P/M 42C, CR-P/M 42V, CR-P/M 52D,
CR-P/M 42BV, CR-P/M 42CV

CR-P/M 62, CR-P/M 62E,
CR-P/M 92, CR-P/M 62V,
CR-P/M 62EV, CR-P/M 92V

2CDC 292 017 F0005

2CDC 292 018 F0005

CR-P/M 22

2CDC 292 016 F0005

5

Description

CR-P/M 62C, CR-P/M 62D, CR-P/M 72, CR-P/M 82
CR-P/M 92C, CR-P/M 62CV, CR-P/M 72A,
CR-P/M 62DV CR-P/M 92CV

5/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Pluggable interface relays
Ordering details - CR-U range
Description

2CDC 291 047 F0004

Interface relays are widely used in various industrial applications:
As an interface they link the electronic controlling, e.g. PLC (programmable logic controller),
PC or field bus systems, to the sensor / actuator level. Here, they take on various functions:
Switching of AC or DC loads with different resistive, inductive and capacitive parts, switching
voltages from a few mV up to 250 V, switching currents from a few mA up to 16 A, amplification of weak control signals, electrical isolation of control and load circuits, and signal multiplying. In contrast to electronic switching devices, interface relays don’t use additional internal
protective circuits and thus are overload-proof against short-time variations like current or
voltage peaks.

CR-U

Ordering details - CR-U range

2CDC 291 007 S0011

Rated control
supply voltage
12 V DC
24 V DC
48 V DC
110 V DC
220 V DC
24 V AC
48 V AC
110 V AC
120 V AC
230 V AC
12 V DC
24 V DC
48 V DC
110 V DC
125 V DC
220 V DC
24 V AC
48 V AC
60 V AC
110 V AC
120 V AC
230 V AC
12 V DC
24 V DC
48 V DC
110 V DC
220 V DC
24 V AC
48 V AC
110 V AC
120 V AC
230 V AC
12 V DC
24 V DC
48 V DC
110 V DC
220 V DC
24 V AC
48 V AC
110 V AC
120 V AC
230 V AC

Outputs

Contact
ratings

2 c/o
without LED

250 V, 10 A

3 c/o
without LED

250 V, 10 A

2 c/o
with LED

250 V, 10 A

3 c/o
with LED

250 V, 10 A

Type
CR-U012DC2
CR-U024DC2
CR-U048DC2
CR-U110DC2
CR-U220DC2
CR-U024AC2
CR-U048AC2
CR-U110AC2
CR-U120AC2
CR-U230AC2
CR-U012DC3
CR-U024DC3
CR-U048DC3
CR-U110DC3
CR-U125DC3
CR-U220DC3
CR-U024AC3
CR-U048AC3
CR-U060AC3
CR-U110AC3
CR-U120AC3
CR-U230AC3
CR-U012DC2L
CR-U024DC2L
CR-U048DC2L
CR-U110DC2L
CR-U220DC2L
CR-U024AC2L
CR-U048AC2L
CR-U110AC2L
CR-U120AC2L
CR-U230AC2L
CR-U012DC3L
CR-U024DC3L
CR-U048DC3L
CR-U110DC3L
CR-U220DC3L
CR-U024AC3L
CR-U048AC3L
CR-U110AC3L
CR-U120AC3L
CR-U230AC3L

Order code

Price

1SVR405621R4000
1SVR405621R1000
1SVR405621R6000
1SVR405621R8000
1SVR405621R9000
1SVR405621R0000
1SVR405621R5000
1SVR405621R7000
1SVR405621R2000
1SVR405621R3000
1SVR405622R4000
1SVR405622R1000
1SVR405622R6000
1SVR405622R8000
1SVR405622R8200
1SVR405622R9000
1SVR405622R0000
1SVR405622R5000
1SVR405622R5200
1SVR405622R7000
1SVR405622R2000
1SVR405622R3000
1SVR405621R4100
1SVR405621R1100
1SVR405621R6100
1SVR405621R8100
1SVR405621R9100
1SVR405621R0100
1SVR405621R5100
1SVR405621R7100
1SVR405621R2100
1SVR405621R3100
1SVR405622R4100
1SVR405622R1100
1SVR405622R6100
1SVR405622R8100
1SVR405622R9100
1SVR405622R0100
1SVR405622R5100
1SVR405622R7100
1SVR405622R2100
1SVR405622R3100

Pkg Weight
(1 pce)
qty kg (lb)

10

0.083
(0.183)

10

0.083
(0.183)

10

0.083
(0.183)

10

0.083
(0.183)

Ordering details - Accessories
Version

Type

Order code

CR-U2S

Socket for 2 c/o and module
Socket for 3 c/o and module
Socket for 3 c/o

CR-U2S
CR-U3S
CR-U3E

1SVR405670R0000
1SVR405660R0000
1SVR405660R0100

Socket small for 2 c/o

CR-U2SM

1SVR405670R1100

Socket small for 3 c/o

CR-U3SM

1SVR405660R1100

Holder for CR-U socket

CR-UH

1SVR405669R0000

Price

Pkg Weight
(1 pce)
qty kg (lb)

10

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/14

5

Pluggable interface relays
Ordering details - CR-U accessories
Ordering details - CR-U range (all products stocked)

6-24 V DC

CR-U...

24-60 V DC
110 V DC

5

Diode Reverse
polarity
protection/
free wheeling
diode
Diode and
LED - Reverse
polarity
protection/
free wheeling
diode

6-24 V AC/DC

Version

24-60 V AC/DC Diode and
LED
110 V DC 110230 V AC

6-24 V AC/DC
Varistor and
24-60 V AC/DC LED
Overvoltage
protection

2CDC 291 032 F0005

110 V DC 110230 V AC

CR-U T

24 V AC
230 V AC

Overvoltage
protection,
varistor

24-240
V AC/DC

Multifunction
time module

115 V AC

Order code

A1+, A2-

CR-U 21

1SVR405661R0000

red, A1+, A2-

CR-U 41

1SVR405662R0000

green, A1+, A2- CR-U 41V
CR-U 41B
red, A1+, A2-

1SVR405662R1000

green, A1+, A2- CR-U 41BV
CR-U 41C
red, A1+, A2-

1SVR405662R4100

green, A1+, A2- CR-U 41CV
CR-U 51B

1SVR405662R9100

24-60 V AC/DC Spark quenching
110-230
V AC/DC
6-24 V AC/DC

Type

red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2-

pluggable onto
CR-U2S and
CR-U3S

1SVR405662R4000

Price

Pkg Weight
(1 pce)
qty

kg (lb)

10

0.007
(0.015)

10

0.007
(0.015)

10

0.007
(0.015)

10

0.007
(0.015)

10

0.007
(0.015)

10

0.007
(0.015)

10

0.014
(0.031)

1SVR405662R9000
1SVR405663R0000

CR-U 51D

1SVR405663R4000

CR-U 51C

1SVR405663R1000

CR-U 61

1SVR405664R0000

CR-U 61V

1SVR405664R1000

CR-U 61E

1SVR405664R4000

CR-U 61EV

1SVR405664R4100

CR-U 91

1SVR405664R0100

CR-U 91V

1SVR405664R1100

CR-U 61C

1SVR405665R0000

CR-U 61CV

1SVR405665R1000

CR-U 61D

1SVR405665R4000

CR-U 61DV

1SVR405665R4100

CR-U 91C

1SVR405665R0100

CR-U 91CV

1SVR405665R1100

CR-U 71

1SVR405666R0000

CR-U 71A
CR-U 81

1SVR405666R1000

CR-U T

1SVR405667R0000

1SVR405666R2000

All CR-U modules can be plugged onto sockets CR-U2S and CR-U3S.

2CDC 292 013 F0005

2CDC 292 014 F0005

Connection diagrams

2CDC 292 015 F0005

6-220 V DC

Description

CR-U 41, CR-U 41B, CR-U 41C,
CR-U 41V, CR-U 41BV, CR-U 41CV

CR-U 61, CR-U 61E, CR-U 91,
CR-U 61V, CR-U 61EV, CR-U 91V

2CDC 292 017 F0005

2CDC 292 016 F0005

CR-U 21

CR-U 61C, CR-U 61CV, CR-U 61D,
CR-U 61DV, CR-U 91C, CR-U 91CV

5/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CR-U 51B, CR-U 51C CR-U 51D

2CDC 292 018 F0005

2CDC 291 004 S0011

Rated control
supply voltage

CR-U 71, CR-U 71A , CR-U 81

Pluggable interface relays
Technical data - CR-P, CR-M, CR-U
Input circuit - coil data
CR-P range
Rated control Rated
supply
frequency
voltage US

Make voltage MaximumBreak
(at 20 °C)
voltage (at 55 voltage
°C)

Rated power

Coil resistance
(at 20 °C)

Tolerance of
coil
resistance

DC coils

12 V DC
24 V DC
48 V DC
110 V DC

   8.4 V DC
16.8 V DC
33.6 V DC
77 V DC

30.6 V DC
61.2 V DC
122.4 V DC
280 V DC

0.4-0.48
0.4-0.48
0.4-0.48
0.4-0.48

  360 
1440 
5700 
25200 






AC coils

24 V AC
48 V AC

50 / 60 Hz
50 / 60 Hz

19.2 V AC
38.4 V AC

28.8 V AC
57.6 V AC

110 V AC
120 V AC
230 V AC

50 / 60 Hz
50 / 60 Hz
50 / 60 Hz

-






0.1
0.1
0.1
0.1

US
US
US
US

W
W
W
W

10%
10%
10%
10%

 0.15 U S
 0.15 U S

0.75 VA
0.75 VA

  400 
1550 

 10%
 10%

 0.15 U S
 0.15 U S
 0.15 U S

0.75 VA
0.75 VA
0.75 VA

8900 
10200 
38500 

 10%
 10%
 10%

Make voltage Maximum
Break
(at 20 °C)
voltage (at 55 voltage
°C)

Rated power

Coil resistance (at 20
°C)

Tolerance of
coil
resistance

88 V AC
96 V AC
184 V AC

132 V AC
144 V AC
276 V AC

CR-M range
Rated control Rated
supply
frequency
voltage US

DC coils

AC coils

12 V DC
24 V DC
48 V DC

-

   9.6 V DC
19.2 DC
38.4 V DC

60 V DC
110 V DC
125 V DC

-

220 V DC

-

24 V AC
48 V AC
60 V AC
110 V AC
120 V AC
230 V AC

50
50
50
50
50
50

/
/
/
/
/
/

60
60
60
60
60
60

Hz
Hz
Hz
Hz
Hz
Hz

13.2 V DC
26.4 V DC
52.8 V DC

 0.1 U S
 0.1 U S
 0.1 U S

0.9 W
0.9 W
0.9 W

160 
640 
2600 

 10%
 10%
 10%

48 V DC
88 V DC
100 V DC

66 V DC
121 V DC
137.5 V DC

 0.1 U S
 0.1 U S
 0.1 U S

0.9 W
0.9 W
0.9 W

4000 
13600 
16000 

 10%
 10%
 10%

176 V DC

242 V DC

 0.1 U S

0.9 W

54000 

 10%

26.4 V AC
52.8 V AC
66 V AC
121 V AC
132 V AC
253 V AC








1.6
1.6
1.6
1.6
1.6
1.6

158 
640 
930 
3450 
3770 
16100 








19.2 V AC
38.4 V AC
48 V AC
88 V AC
96 V AC
184 V AC

0.2
0.2
0.2
0.2
0.2
0.2

US
US
US
US
US
US

VA
VA
VA
VA
VA
VA

10%
10%
10%
10%
10%
10%

CR-U range
Rated control Rated
supply
frequency
voltage US

Make voltage Maximum
Break
(at 20 °C)
voltage (at 55 voltage
°C)

Rated power

Coil resistance
(at 20 °C)

Tolerance of
coil
resistance

DC coils

12 V DC
24 V DC
48 V DC
110 V DC
125 V DC
220 V DC

-

9.6 V DC
19.2 V DC
38.4 V DC
88.0 V DC
100 V DC
176.0 V DC

13.2 V DC
26.4 V DC
52.8 V DC
121.0 V DC
137.5 V DC
242.0 V DC








1.5
1.5
1.5
1.5
1.5
1.5

W
W
W
W
W
W

110 
430 
1750 
9200 
11000 
37000 








AC coils

24 V AC

50 / 60 Hz

19.2 V AC

26.4 V AC

 0.15 U S

 10 %

50 / 60 Hz

38.4 V AC

52.8 V AC

 0.15 U S

305 

 10 %

60 V AC

50 / 60 Hz

48.0 V AC

66.0 V AC

 0.15 U S

475 

 10 %

110 V AC

50 / 60 Hz

88.0 V AC

121.0 V AC

 0.15 U S

1700 

 10 %

120 V AC

50 / 60 Hz

96.0 V AC

132.0 V AC

 0.15 U S

1910 

 10 %

230 V AC

50 / 60 Hz

184.0 V AC

253.0 V AC

 0.15 U S

VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA

75 

48 V AC

2.8
2.5
2.8
2.5
2.8
2.5
2.8
2.5
2.8
2.5
2.8
2.5

7080 

 10 %

0.1
0.1
0.1
0.1
0.1
0.1

Us
Us
Us
Us
Us
Us

(50
(60
(50
(60
(50
(60
(50
(60
(50
(60
(50
(60

Hz)
Hz)
Hz)
Hz)
Hz)
Hz)
Hz)
Hz)
Hz)
Hz)
Hz)
Hz)

10
10
10
10
10
10

%
%
%
%
%
%

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/16

5

Pluggable interface relays
Technical data - CR-P, CR-M, CR-U
CR-P...1

Type
Output circuit(s)

11-12/14

Kind of output

Relay, 1 c/o

Contact material

AgNi

Rated operational voltage U e (VDE 0110, IEC 60947-1)

250 V

Minimum switching voltage
Maximum switching voltage

5

CR-P...2

CR-M...2

CR-M...3

11-12/14
21-22/24

11-12/14
21-22/24

11-12/14
21-22/24
31-32/34

Relay, 2 c/o
AgNi
AgNi/Au 5 µm

Relay, 2 c/o

Relay, 3 c/o

AgNi

AgNi

5V

10 V (AgNi)

DC

300 V DC

250 V DC

AC

CR-M...4
11-12/14
21-22/24
31-32/34
41-42/44
Relay, 4 c/o
AgNi
AgNi/Au 5 µm
5 V (AgNi/Au)

CR-U...2
11-12/14
31-32/34

11-12/14
21-22/24
31-32/34

Relay, 2 c/o

Relay, 3 c/o

AgNi
10 V

440 V AC

250 V AC

Minimum switching current

5 mA (AgNi), 2 mA (AgNi/Au)

5 mA (AgNi)

5 mA (AgNi)

2 mA (AgNi/Au)

5 mA

Rated free air thermal current I th
AC-12 (resistive) 230 V
Rated
AC-15 (inductive) 230 V
­o perational
AC-15 (inductive) 120 V
current
(IEC 60947DC-12 (resistive) 24 V
5-1)
DC-13 (inductive) 24 V
DC-13 (inductive) 120 V
DC-13 (inductive) 250 V
AC rating
Utilization category (pilot duty)
(Contact rating code designation)
(UL 508)
max. rated operational voltage

16 A
16 A
1.5 A
3A
16 A
2.5 A
0.22 A
0.1 A

8A
8A
1.5 A

12 A
12 A
1.5 A

10 A
10 A
1.5 A

8A
2A

12 A
2.5 A

10 A
2.5 A

6A
6A
1A
1.5 A
6A
2A

10 A
10 A
1.5 A
3A
10 A
2A

440 V AC

B300

B300

B300

300 V AC

300 V AC

300 V AC

Max. continuous thermal current
at utilization category

5A

5A

Max. making / breaking apparent
power at utilization category

3600 / 360 VA

3600 / 360 VA

Utilization category (resistive)
(CSA22.2 No.14....)
DC rating *
(UL 508;
NEMA ICS-5)

Utilization category (pilot duty)
(Contact rating code designation)
Max. rated operational voltage
Max. continuous thermal current
at utilization category
Max. making / breaking apparent
power at utilization category
Utilization category (resistive)
(CSA22.2 No.14....)

16 A,
250 V AC

8 A,
250 V AC

10 A, 250 V AC
12 A, 150 V AC

5A

6 A, 250 V AC
10 A, 150 V AC

2.5 A

5A

1800 /
180 VA

3600/360 VA

5 A, 250 V AC
10 A, 150 V AC

10 A, 250 V AC (resistive +
single-phase)

R300
300 V DC
1A
28 VA
-

10 A, 24 V DC -

Maximum making (inrush) current

30 A

15 A

Minimum switching power

0.3 W (AgNi), 0.05 W (AgNi/Au)

0.3 W (AgNi), 0.1 W (AgNi/Au)

0.3 W

4000 VA

3000 VA

2500 VA

Maximum switching
(breaking) power

AC1 (resistive)

Contact resistance

CR-U...3

2000 VA

24 A

10 A, 28 V DC
20 A
2500 VA

12 A
1500 VA

20 A

 100 m
600 switching cycles/h

1200 switching cycles/h

72000 switching cycles/h

18000 switching cycles/h

> 3 x 107 switching cycles
> 0.7 x 10 5
> 10 5
switching
switching
cycles (16 A, cycles (8 A,
250 V)
250 V)
see reduction factor F

> 2 x 107 switching cycles
> 10 5 switching cycles
(12 A, 250 V) (10 A, 250 V) (6 A, 250 V)

> 10 5 switching cycles
(12 A, 250 V)

Response time

typ. 7 ms

typ. 13 ms (DC),10 ms (AC)

typ. 18 ms (DC), 12 ms (AC)

Release time

typ. 3 ms

typ. 3 ms (DC), 8 ms (AC)

typ. 7 ms (DC), 10 ms (AC)

Isolation data
Rated insulation voltage

400 V AC

250 V AC

Insulation class

C250 / B400

C250 / B250

between coil and contacts

5 kV AC

2.5 kV AC

between open contacts

1 kV AC

1.5 kV AC

Maximum operating
frequency

rated load AC-1
without load

Mechanical lifetime
Electrical lifetime

electrical AC1
(resistive)
cos ϕ

Rated
impulse
withstand
voltage U imp

between c/o (SPDT) contacts

-

2.5 kV AC

12000 switching cycles/h

C250

2.5 kV AC

 2 kV AC

2 kV AC

Clearance between coil and contacts

 10 mm

 2.5 mm

 1.6 mm

 3 mm

Creepage distancebetween coil and contacts
Overvoltage category

 10 mm
III

 4 mm
III

 3.2 mm
II

 4.2 mm
III

Pollution degree

3

3

2

3

* Those ratings are based on different type tests but they are not covered by the cULus or CSA approvals.

5/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Pluggable interface relays
Technical data, load limit curves - CR-P, CR-M, CR-U
CR-P...1

Type

CR-P...2

CR-M...2

CR-M...3

CR-M...4

CR-U...2

CR-U...3

General data
Dimensions (W x H x D) when mounted

12.7 x 29 x 15.7 mm

21.2 x 27.5 x 35.6 mm

35 x 35 x 54.4 mm

Weight

14 g (0.031 lb)

35 g (0.077 lb)

83 g (0.18 lb)

Mounting

on socket (see accessories)

Mounting position

any

Degree of protection

IP 67

Electrical connection
Connection

by socket

IP 40

Environmental data
Ambient temperature range

operation

Vibration resistance 10-150
Hz

n/o contact

10 g

5g

5g

n/c contact

10 g

5g

5g

5g

Shock resistance

n/o contact

30 g

20 g

10 g

10 g

n/c contact

30 g

20 g

5g

10 g

IEC/EN 60255-23, IEC/EN 60810-1,
IEC/EN 61810-7

IEC/EN 60255-1

storage

Standards
Product standard

DC: -40...+85 °;
AC: -40...+70 °C

DC: -40...+70 °; AC: -40...+55 °C

-40 ... +85 °C

IEC/EN 60255-23, IEC/EN
60664-1, IEC/EN 61810-1

Low Voltage Directive

5

2006/95/EC

Approvals see page 5/6.

Load limit curves - Maximum switching power at resistive DC load
CR-U with 2 and 3 c/o contacts

DC current [A]
2 = inductive load, T = 40 ms

DC voltage [V]

2CDC 292 023 F0204

1 = resistive load, T = 0 ms

DC voltage [V]

DC voltage [V]

CR-M with 4 c/o contacts

2CDC 292 019 F0204

2CDC 292 015 F0204

DC current [A]

DC voltage [V]

2 = inductive load, T = 40 ms

DC current [A]

CR-M with 3 c/o contacts

DC current [A]

CR-M with 2 c/o contacts

DC voltage [V]

2CDC 292 010 F0204

2CDC 292 005 F0204

DC current [A]

DC voltage [V]

1 = resistive load, T = 0 ms

2CDC 292 028 F0204

CR-P with 2 c/o contacts

DC current [A]

CR-P with 1 c/o contact

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/18

Pluggable interface relays
Technical data - Sockets for CR-P and CR-M
Output circuits
Output circuits
Number of poles
Rated voltage

CR-PLS
CR-PLS(x)
11-12/14, 21-22/24
2
250 V AC
300 V AC

250 V AC

CR-MxLS
CR-MxSS
11-12/14, 21-22/24, ...
2, 3 or 4
250 V AC

Rated current

2 x 10 A1)

2 x 12 A1)

2 x 10 A1)

7A

76 x 15.8 x
62 mm
(2.992 x 0.622
x 2.441 in)

78.5 x 15.5 x
61 mm
(3.011 x 0.610
x 2.402 in)

76 x 15.8 x
42.8 mm
(2.992 x 0.622
x 1.685 in)

General data
Dimensions without holder and
module (L x W x H)

Degree of protection
Temperature range
Connection type

5

terminals IP 20 B (EN 60529)
operation -40...+70 °C -40...+85 °C
storage -40...+70 °C -40...+85 °C
screw connection

Maximum number of wires per
connecting terminal
Wire size

CR-PSS

-40...+70 °C
-40...+70 °C

2

97.5 x 16.3 x
45.2 mm
(3.839 x 0.642
x 1.780 in)

spring
connection
2 (one per
connection
point)

rigid

75 x 27.2 x
60.8 mm
(2.952 x 1.071
x 2.394 in)

with wire end ferule
Stripping length
Tightening torque
Maximum
with 0.2 mm 2
clamping
with 1.5 mm 2
force
with wire end ferrule
Mounting
Material
socket
contacts
contact surface
terminals
combi screw M3
Isolation data
Insulation voltage
Isolation between coil and
contacts

2 x 1.5 mm 2 (2 x 16 AWG)
0.6 Nm
0.8 Nm
DIN rail (IEC/EN 60715)
PA 6+GF - V2
CuZn33
5 μ Ni
5 μ tinned
8 μ Ni
8 μ galvanized
8.8 Steel, 5μ Ni

75.2 x 27.2 x
42.6 mm
(2.961 x 1.071
x 1.677 in)

-40...+70 °C
-40...+70 °C
screw connection
2

Clearance and creepage distance

EN 61984

Standards
Products standard
Low Voltage Directive
EMC Directive

EN 61984
2006/95/EC
-

> 5 kV
EN 61984

> 3 kV

0.2-1.5 mm 2
(24-16 AWG)
0.6 Nm
-

5 μ Ni
8 μ Ni

> 5 kV

10 N
40 N

XCrNi Steel
-

VDE 0106 /
101
DIN EN
60664-1

Loads >10 A ( >12 A for CR-PLSx) require jumpering of terminal 11 with 21, 12 with 22, and 14 with 24

5/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

CR-MxSF
2 or 4

CR-MxLC
300 V AC
10 A

2 x 2.5 mm 2 (2 x 14 AWG)

fine-strand 2 x 2.5 mm 2 (2 x 14 AWG)

1)

CR-PLC

2 x 1.5 mm 2 (2 x 16 AWG)
7 mm (0.28 in)
0.6 Nm (5.31 lb.in)
-

66.7 x 30.3 x
29 mm (2.626
x 1.193 x 1.142
in)

95 x 31 x
42.5 mm
(3.74 x 1.22 x
1.67 in)
-25...+85 °C

fork type
screw
-

spring
connection
2 (one per
connection
point)
2 x 1.5 mm 2 0.2 - 1.5 mm 2
(2 x 16 AWG) (24 x 16 AWG)

-

-

-

10 N
40 N
> 40 N

PA 6+GF - V2
CuZn33
5 μ Ni
8 μ Ni
8.8 Steel, 5μ Ni

6 μ Ni

5 μ tinned
CCSC
-

> 3 kV
EN 61984

> 4 kV
-

EN 61984

EN 61984
2006/95/EC
2004/108/EC

DIN EN
61140,
VDE 0140-1
DIN EN 60664-1

-

-

Pluggable interface relays
Technical data - Sockets for CR-U
Output circuits
Output circuits
Number of poles
Rated voltage

CR-U2S
11-12/14, 21-22/24,...
2
250 V AC

Rated current

10 A

General data
Dimensions without holder and
module (L x W x H)
Degree of protection
terminals
Temperature range
operation
storage
Wire size
rigid

75.3 x 37.3 x 26 mm
(2.965 x 1.469 x 1.024 in)
IP 20 B (EN 60529)
-40...+70 °C
-40...+70 °C
2 x 2.5 mm 2 (2 x 14 AWG)

fine-strand
with wire end ferule
Tightening torque
Mounting
Material
socket
contacts
contact surface
terminals
combi screw M3
Isolation data
Insulation voltage
Isolation between coil and
contacts
Clearance and creepage distance
Standards
Products standard
Low Voltage Directive

2 x 2.5 mm 2 (2 x 14 AWG)
2 x 1.5 mm 2 (2 x 16 AWG)
0.6 Nm
DIN rail (IEC/EN 60715)
PA 6+GF - V2
CuZn33
6 μ Ni
8 μ Ni
8.8 Steel, 5μ Ni

CR-U3S
3

75.3 x 38.1 x 26 mm
(2.965 x 1.500 x 1.024 in)

CR-U3E

CR-UxSM

300 V AC

2 or 3
250 V

70 x 38 x 26 mm
(2.756 x 1.496 x 1.024 in)

61.8 x 38.1 x 26 mm
(2.756 x 1.500 x 1.024 in)

-40...+85 °C
-40...+85 °C

-40...+70 °C
-40...+70 °C

0.8 Nm

0.6 Nm

8 μ galvanized

3 μ Ni
10 μ Ni
Steel, 8 μ Ni

> 2 kV
EN 61984
EN 61984
EN 61984: 2001
2006/95/EC

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/20

5

Pluggable interface relays
Technical data - CR-S range
Rated control
supply
voltage Us

Make voltage
(at 23 °C)

Maxium
voltage
(at 55 °C)

Break voltage

Rated power

Coil
resistance
(at 23 °C)

Tolerance of
coil
resistance

CR-S005VDC1R(G)

5 V DC

3.75 V DC

7.5 V DC

0.25 V DC

170 mW

147 Ω

± 10 %

CR-S012VDC1R(G)

12 V DC

9 V DC

18 V DC

0.6 V DC

170 mW

848 Ω

± 10 %

CR-S024VDC1R(G)

24 V DC

18 V DC

36 V DC

1.2 V DC

170 mW

3390 Ω

± 15 %

CR-S048VDC1R(G)

48 V DC

36 V DC

72 V DC

2.4 V DC

210 mW

10600 Ω

± 15 %

CR-S060VDC1R(G)

60 V DC

45 V DC

90 V DC

3 V DC

210 mW

16600 Ω

± 15 %

Output circuits

5

Output circuits
Kind of output
Contact material

11-12/14
1 c/o (SPDT)
AgSnO 2 / AgSnO 2 /Au

Rated operational voltage U e (IEC/EN 60947-1)

250 V AC

Minimum switching voltage
Maximum switching voltage
Minimum switching current

12 V DC
400 V AC / 125 V DC
100 mA (AgSnO 2) / 10 mA (AgSnO 2 /Au)

Rated free air thermal current I th
Rated operational current (IEC/EN 60947-5-1)

AC rating (UL 508; NEMA ICS-5)
DC rating (UL 508; NEMA ICS-5)
Maximum making (inrush) current
Minimum switching power
Maximum switching (breaking) power
Contact resistance
Maximum operating frequency
Mechanical lifetime
Electrical lifetime
Response time
Release time
Isolation data
Rated insulation voltage
Rated impulse withstand voltage Uimp
Clearance
Creepage distance
Overvoltage category
Pollution degree
General data
Dimensions (W x H x D)
Weight
Mounting
Mounting position
Degree of protection
Electrical connection
Connection
Environmental data
Ambient temperature range
Vibration resistance (10-150 Hz)
Shock resistance
Standards
Product standard
Low Voltage Directive

5A
AC12 (resistive)
230 V
AC15 (inductive)
230 V
AC15 (inductive)
120 V
DC12 (resistive)
24 V
DC13 (inductive)
24 V
DC13 (inductive)
120 V
DC13 (inductive)
250 V
Utilization category (pilot duty)
(Contact rating code designation)
Utilization category (pilot duty)
(Contact rating code designation)

6A
1.5 A
3A
6A
1A
0.22 A
0.11 A
B300
R300
15 A, 240 V AC
100 mA/12 V (AgSnO 2) / 50 mW (AgSnO 2 /Au)

AC1 (resistive) 1500 VA, 250 V AC
100 mW (at 1 A/ 6 V DC)
rated load AC1 360 switching cycles/h
without load 18000 switching cycles/h
1 x 107 switching cycles
AC1 (resistive) (n/c) 3 x 10 4 switching cycles (at +85 °C)
(n/o) 1 x 10 4 switching cycles (at +85 °C)
8 ms
4 ms
250 V AC
between coil and contacts 4000 V AC 1 min
between open contacts 1000 V AC 1 min
between coil and contacts 5.5 mm (0.217 in)
between coil and contacts 8 mm (0.315 in)
III
2
28 x 5 x 15 mm (1.102 x 0.196 x 0.590 in)
5 g (0.011 lb)
on socket
any
RT II and RT III
by socket
operation
storage
n/o contact
n/c contact
n/o contact
n/c contact

5/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

-40...+85 °C
0...+40 °C
10 Hz to 55 Hz 1mm DA
10 Hz to 55 Hz 1mm DA
Functional 49 m/s ² / Destructive 980 m/s ²
Functional 49 m/s ² / Destructive 980 m/s ²
IEC 61810-1
2006/95/EC

Pluggable interface relays
Technical data - CR-S range sockets
Input circuits

CR-S 6-24 V

CR-S 12-24 V

CR-S 48-60 V

CR-S 110-125 V

Rated control supply voltage U s

6-24 V DC

2-24 V AC/DC

48-60 V AC/DC

110-125 V AC/DC 220-240 V AC/DC

Rated control supply voltage U s tolerance

(0.8-1.2) U n

(0.8-1.1) U n

Typical current
Response time
Release time
Status device
Protective circuit
Output circuits

11-29 mA
8 ms
4 ms
green LED
yes

11-16 mA

3.6-4.5 mA

3.6 mA

Output circuits
Number of poles
Rated voltage
Rated current
General data for CR-S with screw connection terminal

11-12/14
1
250 V AC
6A

Dimensions without holder (L x W x H)
Degree of protection (EN 60529)
Temperature range

88.3 x 6.3 x 70.9 mm (3.476 x 0.248 x 2.789 in)
Degree of protection (EN 60529) IP20 (terminals)
operation -40...+70 °C
storage 0...+40 °C
Connection type
Screw
Maximum nuber of wires per connection terminal
2

CR-S 220-240 V

3.6 mA

-40...+55 °C

Wire size

rigid 1 x 2.5 mm² (1 x 14 AWG) ; 2 x 1.5 mm² (2 x 16 AWG)
fine-strand 1 x 2.5 mm² (1 x 14 AWG); 2 x 1.5 mm² (2 x 16 AWG)
with wire end ferule 1 x 2.5 mm² (1 x 14 AWG); 2 x 1.0 mm² (2 x 18 AWG)
Tightening torque
0.5 Nm (4.426 lb.in)
Stripping length
7 mm (0.276 in)
Mounting (IEC/EN 60715)
DIN rail
Material
socket PA6 +GF-V2
contacts CuZn36
contact surface 3 μ Ni/Sn
terminals CuZn40, 3 μ Ni
combi screw M3 Fe
General data for CR-S with spring connection terminal
Dimensions without holder (L x W x H)
88.3 x 6.3 x 70.9 mm (3.476 x 0.248 x 2.789 in)
Degree of protection (EN 60529)
Degree of protection (EN 60529) IP20 (terminals)
Temperature range
operation -40...+70 °C
-40...+55 °C
storage 0...+40 °C
Connection type
Spring
Maximum nuber of wires per connection terminal
1
Wire size
2.5 mm² (14 AWG) rigid, fine-strand and with wire end ferule
Stripping length
7 mm (0.276 in)
Mounting (IEC/EN 60715)
DIN rail
Material
socket PA6 +GF-V2
contacts CuZn36
contact surface 3 μ Ni/Sn
spring terminals SUS301
Isolation data
Isolation between coil and contacts
5000 V AC
Resistance to shock coil to contact
1000 MW
Clearance and creepage distance
IEC/EN 61984
Standards
Product stancard
IEC/EN 61984: 2001
Low Voltage Directive
2006/95/EC

Endurance curve
Operations (*1000 ops)

10
5

2

100
50

1
0.5

0.2

0.1

10

20

50

100

200
DC voltage (V)

5

0

1

2

3

4

5

6

7

8

Contact current (A)

2CDC 292 013 F0214

10

2CDC 292 012 F0214

DC current (A)

Load limit curves - Max. DC load breaking capacity

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/22

5

Pluggable interface relays
Load limit curves
Load limit curves - Electrical lifetime at resistive AC load
CR-P with 2 c/o contacts

CR-M with 4 c/o contacts

Switching power [kVA]

2CDC 292 022 F0204

Switching power [kVA]

2CDC 292 018 F0204

Switching cycles

Switching cycles
2CDC 292 013 F0204

Switching power [kVA]

Switching power [kVA]

2CDC 292 027 F0204

Switching cycles

CR-M with 3 c/o contacts

Switching cycles

CR-M with 2 c/o contacts

Switching power [kVA]

2CDC 292 009 F0204

2CDC 292 003 F0204

Switching power [kVA]

5

CR-U with 2 and 3 c/o contacts

Switching cycles

Switching cycles

CR-P with 1 c/o contact

Reduction factor F at inductive AC load
CR-U

5/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Power factor

2CDC 292 029 F0204

Power factor

2CDC 292 014 F0204

Power factor

2CDC 292 004 F0204

Reduction factor

Reduction factor

CR-M

Reduction factor

CR-P

Pluggable interface relays
Connection diagrams

2CDC 292 016 F0004

2CDC 292 024 F0004

CR-P with 1 c/o contact

2CDC 292 011 F0004

2CDC 292 001 F0004

Connection diagrams

CR-M with 2 c/o contacts

CR-M with 3 c/o contacts

CR-U with 2 c/o contacts

CR-S

2CDC 292 030 F0004

CR-M with 4 c/o contacts

CR-U with 3 c/o contacts

2CDC 292 025 F0004

Dimensions in mm and inches

2CDC 292 002 F0004

2CDC 292 001 F0015

Dimensional drawings

2CDC 292 001 F0014

CR-P with 2 c/o contacts

2CDC 292 020 F0004

2CDC 292 008 F0004

5

CR-U with 2 c/o contacts

CR-M with 2 c/o contacts

CR-P

0.5 0.020
1 0.039
16.38 0.645

5 0.197

3.78 0.149
5.04 0.198

2CDC 292 026 F0004

2CDC 292 002 F0015

0.9 0.035

3.5 0.138

0.5 0.020

2CDC 292 052 F0013

15 0.591

28 1.102

CR-U with 3 c/o contacts

CR-M with 3 c/o contacts

2CDC 292 003 F0015

CR-S

CR-M with 4 c/o contacts

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/24

Pluggable interface relays
Dimensional drawings
Dimensions in mm and inches

62

62

51,2

15,8
7,5

61

29

3.2

5.08
5.08

78.5

Relay

29.4

Pluggable
function module

20.32

2CDC 292 006 F0211

Relay

76

20

10

42.5

Holder

CR-PLS - screw connection

Holder

Pluggable function
module

24

7.62

50
15.5

Marker

42.8

CR-PLSx - screw connection
43,5
33,8
7,62

76

20

10

Holder

24,4

97,5
25,9

9x15 (=139,5)

2CDC 292 010 F0011

5,08

CR-PSS - screw connection

20,32

15,8

5,08

Pluggable
function module

24

2CDC 292 007 F0211

Relay

15,5
2±0,2

2CDC 292 012 F0011

±0,2

R

1

1,5

10

10

6±0,2

141,5+1

16,3
34,4

CR-PLC - spring connection

CR-PJ

76.6 3.016

70.9 2.791

6.2 0.244

55.4 2.181

35.7 1.406
92.7 3.650

73.2 2.882

Spring socket for CR-S range interface relays

Screw socket for CR-S range interface relays

Jumper
6.3 0.248

16.7 0.657

6.7 0.264
123.2 4.850

2CDC 292 002 F0014

0.8 0.031

2.8 0.110

Jumper bar CR-S
5/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Separator for CR-S

71.1 2.799

59.8 2.354

40.2 1.583

20.6 0.811

2CDC 292 054 F0013

52 2.047

88.3 3.476

69.4 2.732

35.4 1.394

28 1.102

44.2 1.74

2CDC 292 053 F0013

94.7 3.728

3.5 0.138

2CDC 292 003 F0014

6.3 0.272

35.8 1.409

35.4 1.394

5

2CDC 292 033 F0004

Marker

Pluggable interface relays
Dimensional drawings
Dimensions in mm and inches
42,5
33,2

24

24

12,4

95

15

2CDC 292 003 F0211

Pluggable
function module

27

Marker

26

42,6

27,2
27,2

27,2

79,5

24

CR-M2LC , CR-M4LC - spring connection
Relay
29 max

2±0,2

27.2 ±0.2

CR-M2SS - CR-M3SS - CR-M4SS - screw connection

2CDC 292 005 F0011

66,7

Pluggable
function module

19

35,4

2CDC 292 004 F0211

75,2

35,4

30,3

Holder

5

246.8

5,5

CR-M2LS - CR-M3LS - CR-M4LS - screw connection

9 x 27.2 (=244,8)

29,1

CR-M4LS

2CDC 292 006 F0005

CR-M3LS

35,4

75
CR-M2LS

Holder

9,5

Relay

R1

CR-MxSF - screw connection

2CDC 292 011 F0011

27,2

31

10

42,6

12,4

27,2

1

60,8

27,2 Marker

6±0,2

CR-MJ

37,3

38,1

4
29,8

29,8

CR-U2S

CR-U3S

CR-U2S - CR-U3S

CR-U3E

38,1

38,1

11 - M3

2CDC 292 002 F0005

CR-U3SM

2CDC 292 009 F0011

35,4

61,8

61,8

8 - M3

CR-U2SM

26

27,8

27,8

CR-U2SM

2CDC 292 081 F0004

2CDC 292 008 F0011

9 - M3

35,4

75,3

75,3

12 - M3

4

CR-U3SM

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/26

Interface relays and optocouplers R600 range
Product group picture

5

5/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Interface relays and optocouplers R600 range
Table of contents

Interface relays and optocouplers R600 range
Benefits and advantages

5/29

Type designators

5/30

Interface relays R600 range. . ............................................................ 5/31
Benefits and advantages

5/31

Selection

5/33

Ordering details

5/35

Connection diagrams

5/37

Technical data

5/38

General technical data

5/43

Dimensional drawings, Load limit curves

5/44

Optocouplers R600 range................................................................ 5/45
Selection

5/45

Ordering details

5/47

Connection diagrams

5/48

Technical data

5/49

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/28

5

2CDC 291 024 F0013

Interface relays and optocouplers R600 range
Benefits and advantages

R600 series

5

Standard range in screw clamp or spring clamp versions
–– Spacing : 6 mm or 12 mm
–– Wire size : 2.5 mm² (4 mm² solid wire)
–– Contact type : 1 NO, 1 NC, 1 SPDT, 1 DPDT from
1 mA to 8 A / 250 V

In today’s automation systems, PLCs are the core of industry. They link sensors and actuators to the process, which are connected to the PLC via conventional wires.
However these PLCs are not completely isolated from the industrial environment, hence over voltage picks and transient currents can affect their operating functions. And additionally, their application field is often limited to 24 VDC / 100 mA.
So, with the aim to adapt application voltage and/or current and provide as well the right electrical isolation to the PLC, it is
recommended to install per I/O the right interface providing both voltage-current level adaptation and isolation protection.
This interfacing is possible thanks to ABB’s relays and optocouplers ranges, which offer wide adaptation in both voltage (from 5
to 400 V) and current (from 10-7 to 16 A) as well as high isolation between input and output from 2 to 4 KV.

5/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Interface relays and optocouplers R600 range
Type designators
SERIES

R600 screw type
R600 spring type

CODE

NB OF RELAYS

CONTACT TYPE

NB OF CONTACTS
PER RELAY

PARTICULARITIES

R/B

n

n

n

n

R/B/R

n

n

n

n

1

012

12

None / A / R

Features
None Input voltage
A
Input voltage

Description of contact types
0

1 Normally Closed 1 NC

1

1 Normally Open 1 NO			

2

1 Change Over or Single Pole Double Through

DC
AC/DC

		
R
RC circuit protection :
- Input protection against leakage current

- Increases relay contacts life

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/30

5

Interface relays R600 range
Benefits and advantages

5

Characteristics
–– Standard range available with screw or spring-type terminals
–– 8 different rated control supply voltages:
DC versions: 5 V, 12 V, 24 V
AC/DC versions: 24 V, 48-60 V, 115 V, 230 V, 60-230 V
–– Output: 1 n/c contact, 1 n/o contact, 1 c/o (SPDT) contact,
2 c/o (SPDT) contacts
–– Devices with output contacts protected by built in RC circuit, which result in increased contact life
–– Devices with leakage current protection on the input side
–– Available with visible or covered switch on the front of the
unit, for the configuration of manual or automatic actuation
–– With connection for jumper bar, except 2 c/o devices and
some discontinued devices
–– Width: 6 mm (0.236 in) or 12 mm (0.472 in)
–– LED for the indication of the operational state
–– Accessories: Jumper bars, separator end section
–– Approvals / Marks

HR

P (pending) / a

1

1 Input - Control supply voltage
2 Jumper bar connection

2

3 Indication of operational states (green LED)
4 Output

3

4

Excellent adaption and conversion of digital signals
AC 110 V
DC 24 V DC 24 V AC 110 V
AC 230V			
AC 230 V

Pushbutton R 600 Relay or		
Position
Optocoupler
PLC
switch			
Sensor

R 600 Relay or
Optocoupler

AC 380 V

Motor
contactor Motor

5/31 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Interface relays R600 range
Benefits and advantages
Interface relays are electromechanic and electronic input and output modules for electrical isolation, levelling, noise suppression or signal
amplification between control unit and process.
Boxed interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC
(programmable logic controller), PC or field bus systems and the sensor / actuator level. The compact design and different connection
terminal possibilities optimize your panel installation.

5
Variety of connections
R600 relays and optocouplers
are available with both screw
terminals or spring terminals.

Space safing
With a width of only 6 mm or 12 mm the
compact design safes space in each
cabinet.

Only one part number AC/DC

0.2 to 2.5 mm²

0.22 to 4 mm²

6 mm spacing

12 mm spacing

Increased contact life
The contacts of some devices are proteced by built in RC-circuits which result
in increased contact life.

Functioning status
Functioning display through a
green LED.

Measurement & Test
Holes for holding DIA. 2 mm test
plugs to simplify any measurement or test.

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/32

10 mA - 6 A

c/o

Screw

Spring
1SNA645534R2500
1SNA645536R2700
1SNA645073R0000
1SNA645035R2400
1SNA645075R0000
1SNA645575R0000
1SNA645535R2600
1SNA645573R0000
1SNA645019R0400
1SNA645519R0600
1SNA645014R2700
1SNA645018R0300
1SNA645514R2100
1SNA645001R0300
1SNA645005R0700
1SNA645501R0500
1SNA645505R0100
1SNA645012R2500
1SNA645512R2700
1SNA645071R0000
1SNA645571R0000
1SNA645072R0000
1SNA645572R0000
1SNA645002R0400
1SNA645006R0000
1SNA645502R0600
1SNA645506R0200
1SNA645040R1500

RBR 121-5VDC
RBR 121-5VDC
RB121-12VDC
RB121-12VDC
RB121-AU-12VDC
RBR121-AU-12VDC
RBR121-12VDC
RBR121-12VDC
RB 101AR-24VAC/DC
RBR 101AR-24VAC/DC
RB 111A-24VAC/DC
RB 111AR-24VAC/DC
RBR 111A-24VAC/DC
RB 121A-24VAC/DC
RB 121A-24VAC/DC
RBR 121A-24VAC/DC
RBR 121A-24VAC/DC
RB 122A-24VAC/DC
RBR 122A-24VAC/DC
RB121-24VDC
RBR121-24VDC
RB121-AU-24VDC
1SNA645572R0000
RB 121A-48-60VAC/DC
RB 121A-48-60VAC/DC
RBR 121A-48-60VAC/DC
RBR 121A-48-60VAC/DC
RB 122A-48-60VAC/DC

RBR 122A-48-60VAC/DC 1SNA645540R1700

48-60 V DC
1SNA645036R2500

24 V DC
RB 121-5VDC

12 V DC
1SNA645034R2300

5 V DC
RB 121-5VDC

Input voltage
Order number

5
Type

Interface relays R600 range
Selection

J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J

115 V DC

230 V DC

60-230 V DC

24 V AC
J

J

1 mA - 6 A

1

J
J

J

1
1

J
J

1 1

J

J

J
J

J

1

J
J

J

1
1

J
1

J
J

J

n/c

1

J

J
J

J

n/o

J
J

J
J

J

Terminal type

1
1
1

J

J

J

5/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

J

J

1

J
J

J
J

J

1
1
1

J

J
J

J

1

J
J

1 mA - 8 A

1

J
J
J

48-60 V AC

115 V AC

230 V AC

60-230 V AC

Output rating

J
J

Output contacts
J
J

2
2 1

J

J
J

J

1

J

J
J

J

1
J

1

J

J

J
J
J
J
J
J

J
J

2
2

J

J

1
1

J

J
J

1

J
1

J

J

J

1SNA645003R0500
1SNA645007R0100
1SNA645046R0700
1SNA645503R0700
1SNA645507R0300
1SNA645546R0100
1SNA645041R0200
1SNA645541R0400
1SNA645016R2100
1SNA645017R2200
1SNA645004R0400
1SNA645008R1200
1SNA645011R2400
1SNA645504R0000
1SNA645508R1400
1SNA645511R2600
1SNA645013R2600
1SNA645513R2000
1SNA645020R0100
1SNA645520R0300

RB 121A-115VAC/DC
RB 121A-115VAC/DC
RB 121AR-115VAC/DC
RBR 121A-115VAC/DC
RBR 121A-115VAC/DC
RBR 121AR-115VAC/DC
RB 122A-115VAC/DC
RBR 122A-115VAC/DC
RB 111A-115VAC/DC
RB 111A-230VAC/DC
RB 121A-230VAC/DC
RB 121A-230VAC/DC
RB 121AR-230VAC/DC
RBR 121A-230VAC/DC
RBR 121A-230VAC/DC
RBR 121AR-230VAC/DC
RB 122A-230VAC/DC
RBR 122A-230VAC/DC
RB 121A 60-230VUC
RBR 121A 60-230VUC

Interface relays R600 range
Selection

J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J

J

1

J
J

J

1

J
J

J

1
J

J

1

J
J

J

1

J
J

1

J

J
J
J

J

J
J

2
2

J

J
J
J

J
J

1
1

J

J
J

J
J

J
J

J

1
1
1

J

J

J
J

J

1

J
J

J

1

J
J

1

J
J
J

J

J
J
J

2
2

J

J
J
J

J
J

1
1

J

J

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/34

5

Interface relays R600 range
Ordering details
Ordering details - 1 n/c contact: 250 V, 10 mA - 6 A (high level), width 12 mm
Rated control Particularities and
supply voltage connection type
24 V AC/DC

RC circuit parallel to
contact on output
side

Type

Order code

RB101AR-24VAC/DC

1SNA645019R0400

RBR101AR-24VAC/DC

1SNA645519R0600

Price

Pkg
qty

Weight
(1 pce)
kg (lb)

5

0.04
(0.088)

Pkg
qty

Weight
(1 pce)
kg (lb)

10

0.02
(0.044)

Pkg
qty

Weight
(1 pce)
kg (lb)

5

0.04
(0.088)

2CDC 291 024 S0013

Ordering details - 1 n/o contact: 250 V, 10 mA - 6 A (high level) width 6 mm

5
R600 - 6 mm

Rated control Particularities and
supply voltage connection type

Type

Order code

24 V AC/DC

RB111A-24VAC/DC

1SNA645014R2700

115 V AC/DC

RB111A-115VAC/DC

1SNA645016R2100

230 V AC/DC

RB111A-230VAC/DC

1SNA645017R2200

24 V AC/DC

RBR111A-24VAC/DC

1SNA645514R2100

Price

screw terminals

Ordering details - 1 n/o contact: 250 V, 10 mA - 6 A (high level), width 12 mm

spring terminals

Rated control Particularities and
supply voltage connection type

24 V AC/DC

RC circuit parallel to
contact on output
side

Type

Order code

RB111AR-24VAC/DC

1SNA645018R0300

RBR111AR-24VAC/DC

1SNA645518R0500

Price

Ordering details - 1 c/o (SPDT) contact: 250 V, 1 mA - 6 A (low level), width 6 mm
Rated control Particularities and
supply voltage connection type
5 V DC

A1-A2 polarized

Type

Order code

RB121-5VDC

1SNA645036R2500

12 V DC

RB121-AU-12VDC

1SNA645075R0000

24 V DC

RB121-AU-24VDC

1SNA645072R0000

24 V AC/DC

RB121A-24VAC/DC

1SNA645005R0700

48-60 V AC/DC

RB121A-48-60VAC/DC

1SNA645006R0000

115 V AC/DC

RB121A-115VAC/DC

1SNA645007R0100

RB121A-230VAC/DC

1SNA645008R1200

RBR121-5VDC

1SNA645536R2700

12 V DC

RBR121-AU-12VDC

1SNA645575R0000

24 V DC

RBR121-AU-24VDC

1SNA645572R0000

24 V AC/DC

RBR121A-24VAC/DC

1SNA645505R0100

48-60 V AC/DC

RBR121A-48-60VUC

1SNA645506R0200

115 V AC/DC

RBR121A-115VAC/DC

1SNA645507R0300

230 V AC/DC

RBR121A-230VAC/DC

1SNA645508R1400

230 V AC/DC
5 V DC

A1-A2 polarized

5/35 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Price

Pkg
qty

Weight
(1 pce)
kg (lb)

10

0.02
(0.044)

Interface relays R600 range
Ordering details

2CDC 291 013 S0013

Ordering details - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A (high level), width 6 mm

R600 - 12 mm

screw terminals

Rated control Particularities and
supply
connection type
voltage

Type

Order code

5 V DC

A1-A2 polarized

RB121-5VDC

1SNA645034R2300

12 V DC

A1-A2 polarized

RB121-12VDC

1SNA645035R2400

12 V DC

RB121-12VDC

1SNA645073R0000

24 V DC

RB121-24VDC

1SNA645071R0000

24 V AC/DC

RB121A-24VAC/DC

1SNA645001R0300

48-60 V AC/DC

RB121A-48-60VAC/DC

1SNA645002R0400

115 V AC/DC

RB121A-115VAC/DC

1SNA645003R0500

230 V AC/DC

RB121A-230VAC/DC

1SNA645004R0400

5 V DC

A1-A2 polarized

RBR121-5VDC

1SNA645534R2500

12 V DC

A1-A2 polarized

RBR121-12VDC

1SNA645535R2600

12 V DC

RBR121-12VDC

1SNA645573R0000

24 V DC

RBR121-24VDC

1SNA645571R0000

24 V AC/DC

RBR121A-24VAC/DC

1SNA645501R0500

48-60 V AC/DC

RBR121A-48-60VUC

1SNA645502R0600

115 V AC/DC

RBR121A-115VAC/DC

1SNA645503R0700

230 V AC/DC

RBR121A-230VAC/DC

1SNA645504R0000

Price

Pkg
qty

Weight
(1 pce)
kg (lb)

10

0.02
(0.044)

5

spring terminals

Ordering details - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A (high level), width 12 mm
Rated control Particularities and
supply voltage connection type

Type

Order code

60-230 V AC/DC

RB121A-60-230VUC

1SNA645020R0100

115 V AC/DC

RB121AR-115VAC/DC

1SNA645046R0700

RB121AR-230VAC/DC

1SNA645011R2400

RBR121A-60-230VUC

1SNA645520R0300

RBR121AR-115VAC/DC

1SNA645546R0100

RBR121AR-230VAC/DC

1SNA645511R2600

230 V AC/DC

Leakage current
protection, input side

60-230 V AC/DC
115 V AC/DC
230 V AC/DC

Leakage current
protection, input side

Price

Pkg
qty

Weight
(1 pce)
kg (lb)

0.04
(0.088)

Ordering details - 2 c/o (SPDT) contacts: 250 V, 1 mA - 8 A (low level), width 12 mm
Rated control
supply voltage

Connection type

Type

Order code

24 V AC/DC

RB122A-24VAC/DC

1SNA645012R2500

48-60 V AC/DC

RB122A-48-60VAC/DC

1SNA645040R1500

115 V AC/DC

RB122A-115VAC/DC

1SNA645041R0200

230 V AC/DC

RB122A-230VAC/DC

1SNA645013R2600

24 V AC/DC

RBR122A-24VAC/DC

1SNA645512R2700

48-60 V AC/DC

RBR122A-48-60VUC

1SNA645540R1700

115 V AC/DC

RBR122A-115VAC/DC

1SNA645541R0400

230 V AC/DC

RBR122A-230VAC/DC

1SNA645513R2000

Type

Order code

24 V AC/DC

BJ 612-10

1SNA290488R0100

48-60 V AC/DC

BJ 612-20

1SNA206754R0000

230 V AC/DC

SC 612

1SNA290474R0200

Price

Pkg
qty

Weight
(1 pce)
kg (lb)

5

0.04
(0.088)

Pkg
qty

Weight
(1 pce)
kg (lb)
0.05
(0.11)
0.01
(0.022)
0.05
(0.11)

Ordering details - Accessories
Description

BJ...

SC612

Price

10

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/36

Interface relays R600 range
Connection diagrams
Control supply voltage
Connection for jumper bar (input side)
Connection for jumper bar (output side)

A1

RB/RBR 101 AR

A2
S1

S2

RB/RBR 111 A - 24 V AC/DC

5

13

11

S2

RB/RBR 121
- 5 V DC, A1-A2 polarized
- 12 V DC, A1-A2 polarized, i.e. only:
1SNA645035R2400, 1SNA645535R2600

RB/RBR 121 A - 24 V AC/DC

A2
S1

11

S2

2CDC 292 043 F0013

A1

21

A2
S1

11

RB/RBR 122 A - 115/230 V AC/DC

5/37 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

21

A2
S1

RB/RBR 121 AR

12 14 22 24

12 14 22 24
A1

11

A1

RB/RBR 121 A - 48/60/115/230 V AC/DC

RB/RB 122 A - 24/48/60 V AC/DC

S2

12 14

2CDC 292 040 F0013

2CDC 292 039 F0013

11

11

S1

RB/RBR 121 (AU)
- 12/24 V DC, except:
1SNA645035R2400, 1SNA645535R2600
see connection diagram RB...121-5VDC

A1

S2

A2

12 14

12 14
A1

A2
S1

12 14

A2
S1

14

A1

2CDC 292 036 F0013

14

RB/RBR 111 AR

A2
S1

S2

12 14

2CDC 292 035 F0013

S2

A2
S1

RB/RBR 111 A - 48/60/115/230 V AC/DC

A1

A1

A2
S1

14

2CDC 292 033 F0013

11

A1

2CDC 292 031 F0013

S2

2CDC 292 030 F0013

A2
S1

13

13

12
A1

2CDC 292 038 F0013

A1-A2
S1
S2

S2

11

2CDC 292 042 F0013

n/c contact			
n/o contact			
1st c/o contact			
2nd c/o contact

2CDC 292 044 F0013

11-12		
13-14		
11-12/14
21-22/24

Interface relays R600 range
Technical data
Technical data
RB... 111A high level
Input circuit
Rated control supply voltage U s
Rated control supply voltage U s
tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out voltage
Indication of operational states

24 V AC/DC

48 V AC/DC

60 V AC/DC

DC -15 %, +20 %
AC -/+ 10 %
50/60 Hz
0.24 W
0.34 W
0.54 W
10 mA
7 mA
9 mA
4.5 V
8V
8V
green LED V : control supply voltage applied

115 V AC/DC

230 V AC/DC
-15 %, +10 %

0.46 W
4 mA
17 V

0.8 W
3.5 mA
27 V

Output circuit
Kind of output
13-14 relay, 1 n/o contact
Rated operational voltage U e (IEC/EN 60947-1)
250 V AC
Minimum switching voltage
Maximum switching voltage
Minimum switching current
Rated free air thermal current I th

12 V
250 V AC
10 mA
6A

Rated operational
current
(IEC/EN 60947-5-1)

6A
1.5 A
3A
6A
1A
0.2 A
0.1 A
B300

AC-12 (resistive) 230 V
AC-15 (inductive) 230 V
AC-15 (inductive) 120 V
DC-12 (resistive) 24 V
DC-13 (inductive) 24 V
DC-13 (inductive) 120 V
DC-13 (inductive) 230 V
Utilization category (pilot duty)

AC rating
(UL 508;
NEMA ICS-5)
DC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
Minimum switching power
Mechanical lifetime
Electrical lifetime
at AC-15
Response time
Release time
Dimensions and weight
Weight
net weight
Dimension

5

R300
0.6 W / 0.6 VA
1 x 107 switching cycles
1 x 10 5 switching cycles
5 ms
5 ms
8 ms
8 ms
RB 111 A
0.02 kg (0.044 lb)

product dimension 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in)

5 ms
8 ms

6 ms
15 ms

7 ms
15 ms
RBR 111 A

6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/38

Interface relays R600 range
Technical data
Technical data
RB... 111AR high level
Input circuit
Rated control supply voltage U s
Rated control supply voltage U s
tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out voltage
Indication of operational states

24 V AC/DC
DC -15 %, +20 %
AC -/+ 10 %
50/60 Hz
0.24 W
10 mA
4.5 V
green LED V : control supply voltage applied

Output circuit
Kind of output

11-12 13-14 relay, 1 n/o contact
Rated operational voltage U e (IEC/EN 60947-1)
250 V AC

5

RB... 101AR high level

Minimum switching voltage
Maximum switching voltage
Minimum switching current
Rated free air thermal current I th

12 V
250 V AC
10 mA
6A

Rated operational
current
(IEC/EN 60947-5-1)

6A
1.5 A
3A
6A
1A
0.2 A
0.1 A
B300

AC-12 (resistive) 230 V
AC-15 (inductive) 230 V
AC-15 (inductive) 120 V
DC-12 (resistive) 24 V
DC-13 (inductive) 24 V
DC-13 (inductive) 120 V
DC-13 (inductive) 230 V
Utilization category (pilot duty)

AC rating
(UL 508;
NEMA ICS-5)
DC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
Minimum switching power
Mechanical lifetime
Electrical lifetime
at AC-15
Response time
Release time
Dimensions and weight
Weight
net weight
Dimension
product dimension

relay, 1 n/c contact
-

R300
0.6 W / 0.6 VA
1 x 107 switching cycles
1 x 10 5 switching cycles
5 ms
8 ms
RB 111AR / RB 101AR high level
0.03 kg (0.066 lb)
12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in)

5/39 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

RBR 111A / RBR 111AR high level
12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in)

Interface relays R600 range
Technical data
Technical data
RB... 121 / RB... 121A high level
Input circuit
Rated control supply voltage U s
Rated control supply voltage U s
tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out voltage
Indication of operational states

5 V DC

12 V DC

24 V AC/DC

DC -15 %, +20 %
AC -/+ 10 %
50/60 Hz
0.2 W
0.2 W
0.24 W
40 mA
16 mA
10 mA
1.2 V
2.2 V
4.5 V
green LED V : control supply voltage applied

48 V AC/DC

60 V AC/DC

115 V AC/DC 230 V AC/DC
-15 %, +10 %

0.33 W
7 mA
8V

0.54 W
9 mA
8V

0.46 W
4 mA
17 V

0.8 W
3.5 mA
27 V

Output circuit
Kind of output
11-12/14 relay, 1 c/o (SPDT) contact
Rated operational voltage U e (IEC/EN 60947-1)
250 V AC
Minimum switching voltage
Maximum switching voltage
Minimum switching current
Rated free air thermal current I th

12 V
250 V AC
10 mA
6A

Rated operational
current
(IEC/EN 60947-5-1)

6A
1.5 A
3A
6A
1A
0.2 A
0.1 A
B300

AC-12 (resistive) 230 V
AC-15 (inductive) 230 V
AC-15 (inductive) 120 V
DC-12 (resistive) 24 V
DC-13 (inductive) 24 V
DC-13 (inductive) 120 V
DC-13 (inductive) 230 V
Utilization category (pilot duty)

AC rating
(UL 508;
NEMA ICS-5)
DC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
Minimum switching power
Mechanical lifetime
Electrical lifetime
at AC-15
Response time
Release time
Dimensions and weight
Weight
net weight
Dimension
product dimension

5

R300
0.6 W / 0.6 VA
1 x 107 switching cycles
1 x 10 5 switching cycles
5 ms
5 ms
5 ms
8 ms
8 ms
8 ms
RB 121 / RB 121A high level
0.02 kg (0.044 lb)
6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in)

5 ms
8 ms

5 ms
6 ms
7 ms
8 ms
15 ms
16 ms
RBR 121 / RBR 121 A high level

6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/40

Interface relays R600 range
Technical data
Technical data
RB... 121 / RB... 121A low level
Input circuit
Rated control supply voltage U s
Rated control supply voltage U s
tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out voltage
Indication of operational states

5 V DC

12 V DC

24 V AC/DC

DC -15 %, +20 %
AC -/+ 10 %
50/60 Hz
0.2 W
0.2 W
0.24 W
40 mA
16 mA
10 mA
1.2 V
2.2 V
4.5 V
green LED V : control supply voltage applied

48 V AC/DC

60 V AC/DC

115 V AC/DC 230 V AC/DC
-15 %, +10 %

0.33 W
7 mA
8V

0.54 W
9 mA
8V

0.46 W
4 mA
17 V

0.8 W
3.5 mA
27 V

Output circuit
Kind of output
11-12/14 relay, 1 c/o (SPDT) contact
Rated operational voltage U e (IEC/EN 60947-1)
250 V AC

5

Minimum switching voltage
Maximum switching voltage
Minimum switching current
Rated free air thermal current I th

5V
250 V AC
1 mA
6A

Rated operational
current
(IEC/EN 60947-5-1)

6A
1.5 A
3A
6A
1A
0.2 A
0.1 A
B300

AC-12 (resistive) 230 V
AC-15 (inductive) 230 V
AC-15 (inductive) 120 V
DC-12 (resistive) 24 V
DC-13 (inductive) 24 V
DC-13 (inductive) 120 V
DC-13 (inductive) 230 V
Utilization category (pilot duty)

AC rating
(UL 508;
NEMA ICS-5)
DC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
Minimum switching power
Mechanical lifetime
Electrical lifetime
at AC-15
Response time
Release time
Dimensions and weight
Weight
net weight
Dimension
product dimension

R300
0.05 W / 0.05 VA
1 x 107 switching cycles
1 x 10 5 switching cycles
5 ms
5 ms
5 ms
8 ms
8 ms
8 ms
RB 121 / RB 121A low level
0.02 kg (0.044 lb)
6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in)

5/41 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

5 ms
8 ms

5 ms
6 ms
7 ms
8 ms
15 ms
16 ms
RBR 121 / RBR 121 A low level

6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in)

Interface relays R600 range
Technical data
Technical data
RB... 121AR
Input circuit
Rated control supply voltage U s
Rated control supply voltage U s
tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out voltage
Indication of operational states

115 V AC/DC

230 V AC/DC

DC -20%, +15%
-10%, +15%
AC -/+ 10 %
50/60 Hz
2W
2.8 W
18 mA
12 mA
17 V
27 V
green LED V : control supply voltage applied

Output circuit
Kind of output
11-12/14 relay, 1 c/o (SPDT) contact
Rated operational voltage U e (IEC/EN 60947-1)
250 V AC
Minimum switching voltage
Maximum switching voltage
Minimum switching current
Rated free air thermal current I th

12 V
250 V AC
10 mA
6A

Rated operational
current
(IEC/EN 60947-5-1)

6A
1.5 A
3A
6A
1A
0.2 A
0.1 A
B300

AC-12 (resistive) 230 V
AC-15 (inductive) 230 V
AC-15 (inductive) 120 V
DC-12 (resistive) 24 V
DC-13 (inductive) 24 V
DC-13 (inductive) 120 V
DC-13 (inductive) 230 V
Utilization category (pilot duty)

AC rating
(UL 508;
NEMA ICS-5)
DC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
Minimum switching power
Mechanical lifetime
Electrical lifetime
at AC-15
Response time
Release time
Dimensions and weight
Weight
net weight
Dimension
product dimension

5

R300
0.6 W / 0.6 VA
1 x 107 switching cycles
1 x 10 5 switching cycles
6 ms
15 ms

7 ms
16 ms
RB 121AR

RBR 121AR

0.03 kg (0.066 lb)
12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in)

12 x 75 x 75 mm
(0.472 x 2.95 x 2.95 in)

Technical data
RB... 122A low level
Input circuit
Rated control supply voltage U s
Rated control supply voltage U s
tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out
Indication of operational states

24 V AC/DC

48 V AC/DC

60 V AC/DC

DC -15 %, +20 %
AC -/+ 10 %
50/60 Hz
0.48 W
0.62 W
0.96 W
20 mA
13 mA
16 mA
5.4 V
8.8 V
8.8 V V
green LED V : control supply voltage applied

115 V AC/DC

230 V AC/DC
-15 %, +10 %

0.58 W
5 mA
20 V

1.15 W
5 mA
10 V

Output circuit
Kind of output

11-12/14 relay, 1st c/o (SPDT) contact
21-22/24 relay, 2nd c/o (SPDT) contact
Rated operational voltage U e (IEC/EN 60947-1)
250 V AC
Minimum switching voltage
Maximum switching voltage
Minimum switching current
Rated free air thermal current I th

5V
250 V DC - 250 V AC
1 mA
8A

5A

Rated operational
AC-12 (resistive) 230 V
current
DC-12
(resistive) 24 V
(IEC/EN 60947-5-1)
Minimum switching power
Mechanical lifetime
Electrical lifetime
at AC-15
Response time
Release time
Dimensions and weight
Weight
net weight
Dimension
product dimension

8A

5A

8A

5A

5 mW / 5 mVA
2 x 107 switching cycles
1 x 10 5 switching cycles
6 ms
10 ms
10 ms
10 ms
14 ms
14 ms
RB 122A low level
0.03 kg (0.066 lb)
12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in)

6 ms
6 ms
15 ms
15 ms
RBR 122A low level
12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/42

Interface relays R600 range
General technical data
Technical data
General data
Material of housing

Electrical connection
Wire size
Stripping length
Tightening torque
Environmental data
Ambient temperature ranges

5

RBR

Screw terminal

Spring-type terminal

UL 94 V0

Mounting
Degree of protection

RB

DIN Rail
housing / IP20 NEMA1
terminals
fine-stranded 0.22-2.5 mm² (24-14 AWG)
rigid 0.2-4 mm² (24-12 AWG)
9 mm / 0.354 in
0.4-0.6 Nm (3.5-5.3 lb.in)

0.2-2.5 mm² (24-14 AWG)

storage -40...+80 °C
operation -20...+70 °C

Isolation data
Rated insulation voltage U i (IEC/EN 60950-1,
EN 50178)
Rated impulse withstand
input / output
voltage U imp (EN 50178)
shock coil / output
output / output

4000 V RMS
4000 V RMS (RB122A: 3800 V RMS, RB111AR: 3500 V RMS)
4000 V RMS
1000 V RMS

5/43 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Interface relays R600 range
Dimensional drawings, Load limit curves
All interface relays of R600 range

center of rail

center of rail

Spring clamp module

Screw clamp module

5

Load limit curves
Limited load in CC

Voltage [V]

Voltage (Vcc)

Max. DC load breaking capacity

resistive
load

Current (Acc)

Current [A]

Versions with 1 n/o, 1 n/c or 1 c/o contact

24 V
110/120 V
220/230 V

DC-12
6A
0,3 A
0.2 A

AC-12
6A
6A
6A

DC-13
1
0.2 A
0.1 A

Versions with 2 c/o contacts

AC-15
3A
3A
3A

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/44

100 mA

58 V DC

Screw

Spring
J

J
1SNA645021R2600
1SNA645521R2000
1SNA645049R1200
1SNA645549R1400
1SNA645022R2700
1SNA645522R2100
1SNA645050R1700
1SNA645550R1100
1SNA645051R0400
1SNA645025R2200
1SNA645024R2100
1SNA645551R0600
1SNA645525R2400
1SNA645524R2300
1SNA645053R0600
1SNA645553R0000
1SNA645054R0700
1SNA645058R1300
1SNA645554R0100
1SNA645558R1500
1SNA645026R2300
1SNA645059R1400
1SNA645526R2500
1SNA645559R1600
1SNA645027R2400
1SNA645029R0600
1SNA645527R2600
1SNA645529R0000

OBRIC 0100 24VDC
OBIC 0100 48-60VAC/DC
OBRIC 0100 48-60VAC/DC
OBIC 0100 115-230VAC/DC
OBRIC 0100 115-230VAC/DC
OBOC 1000-5-12VDC
OBROC 1000-5-12VDC
OBOC 1000-24VDC
OBOC 1500-24VAC/DC
OBOC 5000-24VDC
OBROC 1000-24VDC
OBROC 1500-24VAC/DC
OBROC 5000-24VDC
OBOC 1000-48-60VAC/DC
OBROC 1000-48-60VAC/DC
OBOC 1000-115VAC/DC
OBOC 5000-115VAC/DC
OBROC 1000-115VAC/DC
OBROC 5000-115VAC/DC
OBOC 1000-230VAC/DC
OBOC 5000-230VAC/DC
OBROC 1000-230VAC/DC
OBROC 5000-230VAC/DC
OBOA 1000-24VDC
OBOA 2000-24VDC
OBROA 1000-24VDC
OBROA 2000-24VDC

J

1SNA645547R0200

J
OBIC 0100 24VDC

24 V DC
OBRIC 0100 5-12VDC

1SNA645047R0000

5-12 V DC
Order number

Input voltage
OBIC 0100 5-12VDC

5
Type

Optocouplers R600 range
Selection

J
J

J
J
J
J
J
J
J
J
J
J
J
J

48-60 V DC

115-230 V DC
J

48-60 V AC
J

J

J

J

J
J

J
J

J

J

J
J

J
J

115 V DC

230 V DC
J

115-230 V AC

J

J

J

J
J
J
J

J
J

24 V AC
J

J
J
J

J

2A

5A
J

J
J

J

J
J
J

J

J
J

J

J

J

5/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

J
J

J

J
J

J
J

J
J

J

J
J

J

J

J
J

J

115 V AC
J

J
J

J

J

J
J

J

J

J

J

J

J

J

J

J

J

J

J

J
J
J

230 V AC

J

J

J

J

J
J
J
J

J
J
J
J

Output rating

J

J
J
J

J

J
J

J
J

J

J
J

1A
J

230 V AC

400 V AC

J

J

J

J
J

Output voltage
J

J

J

J

J

Terminal type

J

J

J

1SNA645061R0600
1SNA645561R0000
1SNA645062R0700
1SNA645562R0100
1SNA645028R0500
1SNA645528R0700

OBOA 1000-48-60VAC/DC
OBROA 1000-48-60VAC/DC
OBOA 1000-115VAC/DC
OBROA 1000-115VAC/DC
OBOA 1000-230VAC/DC
OBROA 1000-230VAC/DC

Optocouplers R600 range
Selection

J
J

J
J
J
J

J
J

J

J

J

J
J
J

J
J
J
J
J
J

J

J

J

J

J

J

5

J
J

J

J

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/46

Optocouplers R600 range
Ordering details
Ordering details - R600 range
R600 Optocoupler

2CDC 291 001 F0013

Optocoupler module 100 mA/DC

Optocoupler module 100 mA/DC

5

Optocoupler module 2 A/DC

screw terminals
spring terminals

Optocoupler module 2 A/DC

Optocoupler module 5 A/DC

Optocoupler module 5 A/DC

Optocoupler module 1 A/AC
6 mm spacing
Optocoupler module 2 A/AC
12 mm spacing
Optocoupler module 1 A/AC
6 mm spacing
Optocoupler module 2 A/AC
12 mm spacing

Accessories

BADH

BADL

D 4/12-3...

SC612
FC2

Order code

OBIC 0100-5-12VDC

1SNA645047R0000

OBIC 0100-24VDC

1SNA645021R2600

OBIC 0100-48-60VAC/DC

1SNA645049R1200

OBIC 0100-115-230VAC/DC

1SNA645022R2700

OBRIC 0100-5-12VDC

1SNA645547R0200

OBRIC 0100-24VDC

1SNA645521R2000

OBRIC 0100-48-60VAC/DC

1SNA645549R1400

OBRIC 0100-115-230VAC/DC

1SNA645522R2100

OBOC 1000-5-12VDC

1SNA645050R1700

OBOC 1000-24VDC

1SNA645051R0400

OBOC 1500-24VAC/DC

1SNA645025R2200

OBOC 1000-48-60VAC/DC

1SNA645053R0600

OBOC 1000-115VAC/DC

1SNA645054R0700

OBOC 1000-230VAC/DC

1SNA645026R2300

OBROC 1000-5-12VDC

1SNA645550R1100

OBROC 1000-24VDC

1SNA645551R0600

OBROC 1500-24VAC/DC

1SNA645525R2400

Price

OBROC 1000-48-60VAC/DC 1SNA645553R0000
OBROC 1000-115VAC/DC

1SNA645554R0100

OBROC 1000-230VAC/DC
OBOC 5000-24VDC
OBOC 5000-115VAC/DC

1SNA645526R2500
1SNA645024R2100
1SNA645058R1300

OBOC 5000-230VAC/DC

1SNA645059R1400

OBROC 5000-24VDC

1SNA645524R2300

OBROC 5000-115VAC/DC

1SNA645558R1500

OBROC 5000-230VAC/DC

1SNA645559R1600

OBOA 1000-24VDC

1SNA645027R2400

OBOA 1000-48-60VAC/DC

1SNA645061R0600

OBOA 1000-115VAC/DC

1SNA645062R0700

OBOA 1000-230VAC/DC

1SNA645028R0500

OBOA 2000-24VDC

1SNA645029R0600

OBROA 1000-24VDC

1SNA645527R2600

OBROA 1000-48-60VAC/DC 1SNA645561R0000
OBROA 1000-115VAC/DC

1SNA645562R0100

OBROA 1000-230VAC/DC

1SNA645528R0700

OBROA 2000-24VDC

1SNA645529R0000

Weight
(1 pce)
kg (lb)

10

0.02
(0.44)

10

0.02
(0.44)

10

0.02
(0.44)

10

0.02
(0.44)

10

0.02
(0.44)

10

0.02
(0.44)

10

0.03
(0.066)

5

0.03
(0.066)

10

0.03
(0.066)

5

0.03
(0.066)

Pkg
qty

Weight
(1 pce)
kg (lb)

Order code

BADH V0

1SNA116900R2700

50

BADL V0

1SNA399903R0200

50

BAM2 V0

1SNA399967R0100

50

Seperator end section

SC 612

1SNA290474R0200

10

Divisible shunt 10 poles

BJ 612-10

1SNA290488R0100

10

Divisible shunt 20 poles

BJ 612-20

1SNA206754R0000

10

Test plug DIA. 2 mm

FC2

1SNA645531R2200

10

Marking method

RC65 / RC610

see marking

5/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Price

Pkg
qty

Type

End section

BJ...

Type

Optocouplers R600 range
Connection diagrams

OB...IC 0100 - 5-12 V DC
115-230 V AC/DC

OB...IC 0100
24 V DC
24-48-60 V AC/DC

OB...OC 1000 - 5-12 V DC

5
OB...OC 1500 - 24 V AC/DC
OB...OC 1000
24 V DC
48-60-115-230 V AC/DC

OB...OC 5000
24 V DC
24-48-60-115-230 V AC/DC

OB...OA 1000
24 V DC
48-60-115-230 V AC/DC
OB...OA 2000 - 24 V DC

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/48

Optocouplers R600 range
Technical data
Optocoupler : 5 to 58 V DC output / 100 mA - 6 mm 0.236“ spacing
OB...IC 0100
Relay characteristics coil
Input voltage: +20%, -15% on DC ; 10%, -10% on AC

5 V DC - 12 V DC

24 V DC

Frequency
Input current AC/DC

5 mA

Pull-in voltage at Is=100%

4V

Switching time C / O

10 µs / 500 µs

Operating frequency

1000 Hz

9 mA

7 mA /
16 mA

5 mA

11.5 mA /
25 mA

4 mA

4 mA

15 V

25 V

60 V AC / 70 V DC

5 ms / 20 ms

5 ms / 15 ms

20 Hz

Output

0.9 mA

Output voltage

4.5 to 58 V DC

Output current min.

1 mA

Output current max.

100 mA

Output leakage current at U max.
Residual voltage at I max and
U rated

230 V AC/DC

50 / 60 Hz

Permissible leakage current

5

48 V AC/DC 60 V AC/DC 115 V AC/DC

1 mA

0.9 mA

1.6 mA

< 50 µA
typical 1 V
max 1.3 V

Frequency on inductive load
Isolation Input / Output
Temperature

input /
2500 V RMS
Output
storage -40...+80 °C
operating -20...+70 °C

1)

Screw clamp

Other characteristics
Body material
Wire size
Rated wire size

Spring clamp

grey UL 94 V0
Solid wire 0.2 - 4 mm ² (24-12 AWG)
Stranded
0.22 - 2.5 mm² (24-12 AWG)
wire
2.5 mm ² (12 AWG)

0.2-2.5 mm² (24-12 AWG)

Wire stripping length

9 mm (0.354 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending for 12 V DC) ,
(pending),
, LRS ,
CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Reference standards
1)

Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased.

Dimensional drawings

center of rail

center of rail

Screw clamp module

Spring clamp module

5/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Optocouplers R600 range
Technical data
Optocoupler : 5 to 58 V DC output / 2 A - 6 mm 0.236“ spacing
OB..OC

OB...OC 0100

OB...OC 1000

1500

Relay characteristics coil
Input voltage: +20%, -15% on DC ; 10%, -10%
5 V DC - 12 V DC
on AC

24 V DC

Frequency

24 V AC/
DC

48 V AC/
DC

60 V AC/
DC

115 V AC/
DC

230 V AC/
DC

5.1 mA

4.2 mA

4 mA

50 / 60 Hz

Input current

5 mA

Pull-in voltage at Is=100%

9 mA

4 mA

6.3 mA

4 mA

4V

15 V

15 V

27 V

50 V

80 V

Switching time C / O

15 µs / 250 µs

30 µs /
400 µs

1 ms / 7
ms

5 ms / 20 ms

500 µs /
10 ms

1 ms /
15 ms

Operating frequency

2000 Hz

1000 Hz

60 Hz

20 Hz

Permissible leakage current

1 mA

0.8 mA

0.9 mA

1 mA

0.3 mA

Output
Output voltage

4.5 to 58 V DC

Output current min.

1 mA

Output current max.

2A

Output leakage current at U max.
Residual voltage at I max and
U rated

5

< 50 µA
typical 0.1 V
max 0.5 V

Frequency on inductive load
Isolation Input / Output
Temperature

input / Output 2500 V RMS
storage -40...+80 °C
operating -20...+70 °C

1)

Screw clamp

Other characteristics
Body material
Wire size

Spring clamp

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)

0.2-2.5 mm² (24-12 AWG)

Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

9 mm (0.354 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending for 12 V DC) ,
(pending),
, LRS ,
CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Reference standards
1)

Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased.

Dimensional drawings

center of rail

center of rail

Screw clamp module

Spring clamp module

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/50

Optocouplers R600 range
Technical data
Optocoupler : 5 to 58 V DC output / 5 A - 6 mm 0.236“ spacing
OB... OC 5000
Input
Input voltage

24 V DC

Frequency

115 V AC/DC

230 V AC/DC

50 / 60 Hz

50 / 60 Hz

Input current

5.4 mA

4.2 mA

4 mA

Pull-in voltage at Is=100%

12 V

50 V

80 V

Switching time C / O

30 µs / 400 µs

500 µs / 10 ms

1ms / 15 ms

Operating frequency

1000 Hz

50 Hz

35 Hz

Permissible leakage current

0.8 mA

0.3 mA

0.3 mA

Output

5

Output voltage

4.5- 58 V DC

Output current min.
Output current max.

1 mA
5A

Output leakage current at U max.
Residual voltage at I max and
U rated

< 50 µA
typical 0.1 V
max 0.5 V

Frequency on inductive load
Isolation Input / Output

See Note 1
input / Output 2500 V RMS

Temperature
Ambient temperature

storage -40...+80 °C
operating See derating curve

Other characteristics
Body material
Wire size

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)
Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

10 mm (0.394 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending),
CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Reference standards

Dimensional drawings

center of rail

Screw clamp module

center of rail

Spring clamp module

5/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Optocouplers R600 range
Technical data
Optocoupler : 24 to 400 V AC output / 1 A or 2 A max. - 6 mm or 12 mm spacing
OB...OA

OB...OA 1000

2000

Relay characteristics coil
Input voltage: +20%, -15% on DC ; 10%, -10% on AC

24 V DC

48 V AC/DC

Frequency

60 V AC/DC

115 V AC/DC

230 V AC/DC

24 V DC

50/60 Hz

Input current

3.6 mA

4.3 mA

5.5 mA

4.15 mA

4.6 mA

3.6 mA

Pull-in voltage at Is=100%

14 V

15 V

18 V

60 V

135 V

14 V

Switching time C / O

150 µs / 1 ms

3 ms / 30 ms

2.2 ms / 18 ms

2.5 ms / 25 ms

150 µs / 1
ms

Operating frequency

500 Hz

20 Hz

25 Hz

20 Hz

500 Hz

Permissible leakage current

1 mA

Output
Output voltage

24-400 V AC

Frequency

50/60 Hz

Output current min.

25 mA

Output current max.

1A

Output leakage current at U max.

< 0.50 mA

Residual voltage at I max and
U rated

10-230 V AC

2A

typical 1 V
max 1.6 V

Frequency on inductive load
Isolation Input / Output
Temperature

input / Output 2500 V RMS
storage -40...+80 °C
operating -20...+70 °C

1)

Screw clamp

Other characteristics
Body material
Wire size

Spring clamp

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)

0.2-2.5 mm² (24-12 AWG)

Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

9 mm (0.354 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending for 12 V DC) ,
(pending),
, LRS ,
CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Reference standards
1)

Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased.

Dimensional drawings

center of rail

Screw clamp module

center of rail

Spring clamp module

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/52

5

Logic relays
Product group picture

6

6/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
Table of contents
Logic relays
Logic relays

6/1

Product group picture

6/1

Table of contents

6/2

System overview

6/3

Approvals and marks

6/5

Ordering details - Stand alone logic relays

6/6

Ordering details - Expandable logic relays

6/7

Ordering details

6/8

Ordering details - Display systems

6/9

Technical data

6/10

Dimensional drawings

6/24

6

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/2

Logic relays
System overview

6

Logic links instead of wiring

Steps to the application of CL range
–– CL range can be used easily, rapidly and comfortably
without any time-consuming planning and programming.
–– The user can discover the advantages and the benefit of
these logic relays in no time at all.
–– CL range provides for the control statements according
to a simple circuit diagram.
–– Setup, storage, simulation and documentation are performed using the compact and user-friendly CL-SOFT
software (CL-LAS.PS002).

S1

K1

S6

S4

S5
T1
T1

K1

K2

T1

1SVC 110 000 F 0554

Concept
CL range logic relays are suitable for small and mediumsized control tasks and are able to substitute logic wiring in
a quick and simple manner.
They can be used for applications in control as well as for
timing functions, e.g.
–– in buildings, lighting systems, air-conditioning systems,
general control functions,
–– in small machines and systems or
–– as stand-alone control module for small applications.

Documentation (download from the internet)
Logic relay manual: 1SVC440795M0100
Remote display manual: 1SVC440795M2100
Display system manual: 1SVC440795M1100

Software characteristics (CL-SOFT)
–– Display on a PC monitor according to IEC, ANSI
–– Different languages to choose from
–– Easy installation on all Microsoft WindowsTM operating
systems

Technical data overview
Logic relays
– – 8 or 12 digital inputs
– – 4 or 6 digital relay outputs
– – optionally with 4 or 8 transistor outputs
– – 128 rungs
– – 3 contacts as n/o or n/c contacts in series plus 1 coil
per rung
– – optionally with 2 or 4 analog inputs (not 100-240 V AC
version)
– – power flow display for checking the circuit diagram (devices with display)
– – expansions for local or remote level
– – enclosure color RAL 7035
– – DIN rail mounting

Display system
–– useable as compact HMI logic relay
–– fully graphic, backlit display module
–– 12 digital inputs
–– 4 digital relay outputs
–– optionally with 4 transistor outputs
–– 256 rungs
–– 4 contacts as n/o or n/c contacts in series plus 1 coil
per rung
–– optionally with 4 analog inputs (not 100-240 V AC version)
–– networking-compatible via CL-NET
–– front panel mounting
–– expansion for local

Remote display
–– Remote display up to a distance of 5 m
–– Illustration of text and status displays
–– Remote adjustment via keypad
–– Front panel mounting

Software
– – 16 timing relays 0.01-99:59 h
– – 16 counting relays for up-, down counting
– – 8 weekly timer, 8 annual timers
– – 16 analog value comparators
– – 16 freely editable display texts
– – 32 markers or auxiliary relays

6/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
System overview
Display system R Compact HMI logic relay
Expandable

Stand alone

CL-NET
...

4
10

2

2

Power

1a

1b

3

5

7

4

7

9

Power

8

1

3

3

2
1

6

6, 8b

5

5
8a
9

8b

1a
1b
2
3
4
5
6
7
8a
8b
9

2CDC 312 001 F0b08

8a
9

8b

Logic relay CL-LS..
Expandable logic relay CL-LM..
Power supply CP-D...
I/O expansion CL-LER.., CL-LET.. for logic relays CL-LM..
Coupler unit CL-LEC.. for remote expansion of logic relays CL-LM..
Memory module CL-LAS.MD003 for logic relays CL-LS.., CL-LM..
Connecting cable CL-LAS.TK001, CL-LAS.TK002 to connect PC
CL-LINK plug CL-LAS.TK011
to connect expansion to logic relays CL-LM..
Remote display connection module CL-LDC.S..
Connecting cable CL-LAD.TK007
to connect a remote displays to a logic relay
Display module CL-LDD..

1
2
3
4
5
6
7
8
9
10
K

6

Stand alone with I/O module
2
1

3
1
2

Expansion of logic relays*

Display module CL-LDD..
Display base module CL-LDC.LN..
Display I/O module CL-LDR.., CL-LDT..
Termination resistor CL-LAD.TK009
I/O expansion CL-LER.., CL-LET..
Coupler unit CL-LEC.. for remote expansion
Memory module CL-LAD.MD004 for display base module
Connecting cable CL-LAD.TK002, CL-LAD.TK003,
CL-LAD.TK004
Connecting cable CL-LAD.TK001, CL-LAD.TK011
to connect PC
CL-LINK plug CL-LAS.TK011
for expansion of logic relays CL-LM..
e.g. door of switchgear cabinet

3

2CDC 312 027 F0b06

4
6, 8b

2

2CDC 312 025 F0b06

Logic relays

Display CL-LDD..
Remote display connection module CL-LDC.S..
incl. connecting cable
Display base module CL-LDC.L..

Communication via CL-NET

1
5

2a
1
2

3
4
5

Logic relay CL-LM..
I/O expansion CL-LER.., CL-LET..
2a local expansion
2b remote expansion
Coupler unit CL-LEC.. for remote expansion of logic relays CL-LM..
CL-LINK plug CL-LAS.TK011 for expansion of logic relays CL-LM..
up to 30 m
* max. 1 expansion per logic relay

5

5
4

3
1
1
2
3
4
5

2

3
1

2

2CDC 312 026 F0b06

4

CL-NET
...

2CDC 312 037 F0b07

2b

3

Display CL-LDD..
Display base module CL-LDC.LN.. for CL-NET
Display I/O module CL-LDR.., CL-LDT..
Connecting cable CL-LAD.TK002,
CL-LAD.TK003, CL-LAD.TK004
Termination resistor CL-LAD.TK009

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/4

Logic relays
Approvals and marks

CL-LAD

CL-LAS

Accessories

CL-LDT

CL-LDR

CL-LDC

CL-LDD

Display system

CL-LEC

CL-LET

CL-LER

CL-LMT

CL-LMR

Expansions

B

UL

J

J

J

J

J

J

J

J

J

J

J

J

1)

J

2)

F

CAN/CSA C22.2 No.14

J

J

J

J

J

J

J

J

J

J

J

J

1)

J

2)

J

J

J

J

J

J

J

J

J

J

J

J

1)

J

2)

J

J

J

J

J

J

k

k

J

J

C

CAN/CSA C22.2 No.213
(hazardous locations)
GL

R

EAC

k

k

k

k

P

Lloyds Register

J

J

J

J

a

CE

J

J

J

J

J

J

J

J

J

J

b

C-Tick

k

k

k

k

k

k

k

k

k

k

F

6

CL-LST

Approvals

Logic relays

CL-LSR

J existing
j pending

k

k

k

3)

J

4)

k
3)

J

J
k

4)

k

k

J

J

J

k

k

k

J

Marks

1)
2)
3)
4)

not
not
not
not

for:
for:
for:
for:

CL-LAS-PS002, CL-LAS.TD001, CL-LAS.FD001, CL-LAS.TK002, CL-LAS.TK011
CL-LAD.TK006, CL-LAD.TK011, CL-LAD.FD002
CL-LDC.SDC2, CL-LDC.SAC2, CL-LDC.LAC2, CL-LDC.LNAC2
CL-LDR.16AC2

6/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
Ordering details - Stand alone logic relays

Ordering details - Logic relays stand alone

2CDC 281 034 F0006

Rated operational voltage

24 V AC

100-240 V AC

CL-LSR

12 V DC

24 V DC

2CDC 281 033 F0006

24 V DC

Display Timer Input /
+
Output
Keypad

Type

J

CL-LSR.C12AC1

J
J
J
J
J
J

J
J
J
J
J
J
J
J
J
J

Order code

Price
1 pce

Weight
(1 pce)
kg (lb)

1SVR440712R0300

CL-LSR.CX12AC1 1SVR440712R0200
CL-LSR.12AC2

1SVR440713R0100

CL-LSR.C12AC2

1SVR440713R0300

8 inputs / 4 CL-LSR.CX12AC2 1SVR440713R0200
relay outputs CL-LSR.C12DC1 1SVR440710R0300
0.20 (0.44)

CL-LSR.CX12DC1 1SVR440710R0200
CL-LSR.12DC2

1SVR440711R0100

CL-LSR.C12DC2

1SVR440711R0300

CL-LSR.CX12DC2 1SVR440711R0200
8 inputs /
4 transistor
outputs

CL-LST.C12DC2

1SVR440711R1300

CL-LST.CX12DC2

1SVR440711R1200

6

CL-LST

Ordering details - Display modules

2CDC 281 028 F0006

Rated operational voltage

Type

Order code

Price
1 pce

Weight
(1 pce)
kg (lb)

-

Graphic display 132 x 64
pixel

CL-LDD.XK

1SVR440839R4500

0.14 (0.30)

-

Graphic display 132 x 64
pixel, with keypad

CL-LDD.K

1SVR440839R4400

0.13 (0.29)

1SVR440841R0000

0.16 (0.36)

1SVR440843R0000

0.16 (0.36)

24 V DC

100-240 V AC

CL-LDC.SDC2
Module to displace the display from the logic relay, incl.
connecting cable CL-LAD.
TK007, 5m, lenght adaptable CL-LDC.SAC2

2CDC 281 017 F0007

CL-LDD.K

Description

CL-LDC.S..

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/6

Logic relays
Ordering details - Expandable logic relays

2CDC 311 036 F0006

Ordering details - Logic relays expandable
Rated
operational
voltage
24 V AC
100-240 V AC
CL-LMR

12 V DC
24 V DC

2CDC 311 037 F0007

24 V DC

6

Type

J

CL-LMR.C18AC1

1SVR440722R0300

CL-LMR.CX18AC1

1SVR440722R0200

CL-LMR.C18AC2

1SVR440723R0300

CL-LMR.CX18AC2

1SVR440723R0200

CL-LMR.C18DC1

1SVR440720R0300

CL-LMR.CX18DC1

1SVR440720R0200

CL-LMR.C18DC2

1SVR440721R0300

CL-LMR.CX18DC2

1SVR440721R0200

12 inputs, CL-LMT.C20DC2
8 transistor
CL-LMT.CX20DC2
outputs

1SVR440721R1300

J
J
J
J

J
J
J
J
J
J
J
J
J
J

12 inputs
/ 6 relay
outputs

Order code

Price
1 pce

Weight
(1 pce) kg (lb)

0.36 (0.79)

0.36 (0.79)

1SVR440721R1200

Ordering details - Expansions
Rated operational voltage
-

CL-LER

Display Timer Input /
+
Output
Keypad

Description

Type

Order code

Price
1 pce

2 relay outputs

100-240 V AC

Weight
(1 pce) kg (lb)

CL-LER.2O

1SVR440709R5000

0.07 (0.15)

CL-LER.18AC2

1SVR440723R0000

0.26 (0.57)

CL-LER.18DC2

1SVR440721R0000

0.22 (0.49)

12 inputs, 6 relay outputs

2CDC 311 038 F0006

24 V DC
24 V DC

12 inputs, 8 transistor
outputs

CL-LET.20DC2

1SVR440721R1000

0.21 (0.46)

-

Coupler unit for remote
expansion with a distance
of up to 30 m

CL-LEC.CI000

1SVR440709R0000

0.07 (0.15)

CL-LEC

6/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
Ordering details

Ordering details - CL-LA...
Description

Type

Order code

Price

2CDC 311 012 F0007

1 pce

2CDC 311 014 F0007

CL-LAS.PS002

2CDC 311 013 F0007

CL-LAS.TK001

Weight
(1 pce)
kg (lb)

Software for programming and control of CL
range devices. Installation CD-ROM for Microsoft WindowsTM.

CL-LAS.PS002

1SVR440799R8000

0.10
(0.21)

Memory module for logic relays
Memory size: 32 kB

CL-LAS.MD003

1SVR440799R7000

0.02 (0.04

Cable with serial interface to connect PC and
logic relay. Length: 2 m

CL-LAS.TK001

1SVR440799R6000

0.10 (0.22)

Cable with USB interface to connect PC and
logic relay. Length: 2 m

CL-LAS.TK002

1SVR440799R6100

0.06 (0.13)

Cable for point-to-point connection of remotedisplay connection module and logic relay,
length: 5m, adaptable

CL-LAD.TK007

1SVR440899R6600

0.20 (0.44)

Fixing brackets for screw mounting of logic
relay, expansion, display base module

CL-LAS.FD001

1SVR440799R5000

0.01 (0.01)

Spare plug (CL-LINK) for connection of logic
relay to expansion

CL-LAS.TK011

1SVR440799R5100

0.10 (0.22)

Primary switch mode power supplies,
Rated input voltage: 100-240 V AC
CP-D 24/0.421)
Rated output voltage/current: 24 V DC / 0.42 A

1SVR427041R0000

0.06 (0.13)

Primary switch mode power supplies,
Rated input voltage: 100-240 V AC
Rated output voltage/current: 24 V DC / 1.3 A

1SVR427043R0100

0.19 (0.41)

1)
2)

CP-D 24/1.32)

replaces CL-LAS.SD001, technical data see chapter “Primary switch mode power supplies”
replaces CL-LAS.SD002, technical data see chapter “Primary switch mode power supplies”

CL-LAS.MD003

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/8

6

Logic relays
Ordering details - Display systems
Ordering details - Display systems

2CDC 311 028 F0006

Rated operational voltage

Price
1 pce

Weight
(1 pce)
kg (lb)

CL-LDD.XK

1SVR440839R4500

0.14 (0.30)

-

Display module
Graphic display 132 x 64
pixel, with keypad

CL-LDD.K

1SVR440839R4400

0.13 (0.29)

CL-LDC.LDC2

1SVR440821R0000

CL-LDC.LAC2

1SVR440823R0000

CL-LDC.LNDC2

1SVR440821R1000

CL-LDC.LNAC2

1SVR440823R1000

CL-LDR.16AC2

1SVR440853R0000

CL-LDR.16DC2

1SVR440851R0000

CL-LDR.17DC2

1SVR440851R2000

0.17 (0.38)

CL-LDT.16DC2

1SVR440851R1000

0.14 (0.30)

CL-LDT.17DC2

1SVR440851R3000

0.14 (0.30)

Type

Order code

24 V DC
100-240 V AC
100-240 V AC
24 V DC

2CDC 311 031 F0006

Order code

-

100-240 V AC

6

Type

Display module
Graphic display 132 x 64
pixel

24 V DC
CL-LDD.K

Description

24 V DC
24 V DC
24 V DC

CL-LDC.LN..

Display base module CPU /
power supply
Display base module
CPU / power supply,
networking-compatible
(CL-NET)
Display I/O module
12 inputs, 4 relay outputs
Display I/O module
12 inputs, 4 relay outputs,
1 analog output
Display I/O module
12 inputs, 4 transistor
outputs
Display I/O module
12 inputs, 4 transistor outputs, 1 analog output

0.16 (0.36)

0.17 (0.38)

0.17 (0.38)

Ordering details - CL-LAD...
Description

Price

2CDC 311 018 F0007

1 pce

2CDC 311 019 F0007

CL-LAD.MD004

Memory module for display base modules
Memory size: 256 kB

CL-LAD.MD004

1SVR440899R7000

0.02 (0.03)

Cable with serial interface to connect PC and
display base module

CL-LAD.TK001

1SVR440899R6000

0.11 (0.23)

Cable with USB interface to connect PC and
display base module

CL-LAD.TK011

1SVR440899R6700

Network cable (CL-NET) to connect 2 display
base modules Length: 0.3 m

CL-LAD.TK002

1SVR440899R6100

0.05 (0.12)

Network cable (CL-NET) to connect 2 display
base modules Length: 0.8 m

CL-LAD.TK003

1SVR440899R6200

0.07 (0.14)

Network cable (CL-NET) to connect 2 display
base modules Length: 1.5 m

CL-LAD.TK004

1SVR440899R6300

0.08 (0.18)

Cable for point-to-point connection of remote
display connection modules and display base
module, length adaptable, Length: 5 m

CL-LAD.TK005

1SVR440899R6400

0.20 (0.44)

Cable for point-to-point connection of 2
display base modules, length adaptable.
Length: 5 m

CL-LAD.TK006

1SVR440899R6500

0.12 (0.26)

Termination resistor, content: 2 pieces

CL-LAD.TK009

1SVR440899R6900

0.01 (0.02)

Protective cover, transparent, for harsh environmental conditions and application in the
food industry

CL-LAD.FD001

1SVR440899R1000

0.03 (0.07)

Protective cover, transparent and sealable

CL-LAD.FD011

1SVR440899R2000

0.03 (0.07)

Assembly tool for mounting of display modules

CL-LAD.FD002

1SVR440899R3000

2CDC 311 020 F0006

CL-LAD.TK001

Weight
(1 pce)
kg (lb)

CL-LAD.TK002

6/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type

CL-LSR.C...12DC1

CL-LSR.C...12AC1

CL-LSR...12AC2

Input circuit - supply circuit
Rated operational voltage U e

CL-LSR....12DC2
CL-LST.C...12DC2

12 V DC

24 V DC

24 V AC

100-240 V AC

Rated operational voltage tolerance
Operational voltage range
Rated frequency
Rated frequency tolerance
Residual ripple
Input current
at 12 V DC
at 24 V DC
at 24 V AC
at 115/120 V AC (60 Hz)
at 230/240 V AC (50 Hz)
Power failure buffering (IEC/EN 61131-2)
Power dissipation
at 12 V DC
at 24 V DC
at 24 V AC
at 115/120 V AC
at 230/240 V AC

-15...+30 %
10.2-15.6 V DC
0 Hz
m5%
typ. 140 mA
10 ms
typ. 2 W
-

-15...+20 %
20.4-28.8 V DC

-15...+10 %
20.4-26.4 V AC
50/60 Hz
±5 %
typ. 200 mA
20 ms
typ 5 VA
-

Type

CL-LMR.C...18DC1

CL-LMR.C...18AC1

CL-LMR.C...18AC2

Input circuit - supply circuit
Rated operational voltage U e

CL-LMR.C...18DC2
CL-LMT.C...20DC2

12 V DC

24 V DC

24 V AC

100-240 V AC

Rated operational voltage tolerance
Operational voltage range
Rated frequency
Rated frequency tolerance
Residual ripple
Input current
at 12 V DC
at 24 V DC
at 24 V AC
at 115/120 V AC (60 Hz)
at 230/240 V AC (50 Hz)
Power failure buffering (IEC/EN 61131-2)
Power dissipation
at 12 V DC
at 24 V DC
at 24 V AC
at 115/120 V AC
at 230/240 V AC

-15...+30 %
10.2-15.6 V DC
0 Hz
m5%
typ. 200 mA
10 ms
typ. 3.5 W
-

-15...+20 %
20.4-28.8 V DC

-15...+10 %
20.4-26.4 V AC
50/60 Hz
±5 %
typ. 300 mA
20 ms
typ. 7 VA
-

Type

CL-LER.18DC2
CL-LET.20DC2

CL-LER.18AC2

Rated operational voltage U e

24 V DC

100-240 V AC

Rated operational voltage tolerance
Operational voltage range
Rated frequency
Rated frequency tolerance
Residual ripple
Input current
at 24 V DC
at 115/120 V AC (60 Hz)
at 230/240 V AC (50 Hz)
Power failure buffering (IEC/EN 61131-2)
Power dissipation
at 24 V DC
at 115/120 V AC
at 230/240 V AC

-15...+20 %
20.4-28.8 V DC
0 Hz
m5%
typ. 140 mA
10 ms
typ. 3.4 W
-

-15...+10 %
85-264 V AC
50/60 Hz
±5 %
typ. 70 mA
typ. 35 mA
20 ms
typ. 10 VA
typ. 10 VA

Input circuit - supply circuit

typ. 80 mA
typ. 2 W
-

typ. 140 mA
typ. 3.5 W
-

85-264 V AC

typ. 40 mA
typ. 20 mA
typ. 5 VA
typ. 5 VA

6

85-264 V AC

typ. 70 mA
typ. 35 mA
typ. 10 VA
typ. 10 VA

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/10

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type

CL-LSR.C...12DC1

Input circuit - Digital inputs

12 V DC

Number
Inputs can be used as analog inputs
Indication of operational states
Electrical isolation
from voltage supply
between digital inputs
from the outputs
Rated operational
voltage U e
U e on „0“ signal

8
2 (I7, I8)
LCD-Display (if existing)
no
no
yes
12 V DC
24 V DC
4 V DC (I1-I8)
< 5 V DC (I1-I8)

U e on „1“ signal 8 V DC (I1-I8)

Rated frequency
Input current
on „1“ signal

3.3 mA (at 12 V DC,
I1-I6),
1.1 mA (at 12 V DC,
I7, I8)

CL-LSR....12DC2
CL-LST.C...12DC2
24 V DC

> 15 V DC (I1-I6),
> 8 V DC (I7, I8)

3.3 mA (at 24 V DC,
I6-I7),
2.2 mA (at 24 V DC,
I7, I8)

6

Time delay
from „0“ to „1“

debounce ON 20 ms
debounce OFF typ. 0.3 ms (I1-I6),
typ. 0.35 ms (I7, I8)
debounce ON 20 ms

Time delay
from „1“ to „0“

debounce OFF typ. 0.3 ms (I1-I6),
typ. 0.15 ms (I7, I8)

typ. 0,25 ms (I1-I8)

-

CL-LSR.C...12AC1

CL-LSR.C...12AC2

24 V AC

115 / 230 V AC
-

24 V AC
0-6 V AC (sinusoidal)

79-264 V AC
(sinusoidal)

80 ms (at 50 Hz),
66 2/3 ms (at 60 Hz)

80 ms (at 50 Hz, I1-I6),
66 2/3 ms (at 60 Hz,
I1-I6)
160 ms (at 50 Hz, I7, I8),
150 ms (at 60 Hz, I7, I8)
20 ms (at 50 Hz, I1-I6),
16 2/3 ms (at 60 Hz,
I1-I6)
100 ms (at 50 Hz, I7. I8),
100 ms (at 60 Hz, I7, I8)
40 m (I1-I6),
100 m (I7, I8)
-

6x0.25 mA
(at 115 V AC, 60 Hz,
I1-I6),
6x0.5 mA
(at 230 V AC, 50 Hz,
I1-I6)
2x4 mA
(at 115 V AC, 60 Hz,
I7, I8),
2x6 mA
(at 230 V AC, 50 Hz,
I7, I8)
80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz)
20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz)

20 ms (at 50 Hz),
16 2/3 ms (at 60 Hz)

Cable length (unshielded)
Maximum cable length per input

100 m
-

40 m

Frequency counter

2 (I3, I4)
< 1 kHz
square-wave
1:1
2 (I1, I2)
< 1 kHz
square-wave
1:1
< 20 m

-

Rapid counter inputs

Cable length (shielded)
Input circuit - Analog inputs
Number
Electrical isolation

Input type
Signal range
Resolution
Input impedance
Accuracy of the
actual value
Conversion time
analog/digital
Input current
Cable length (shielded)

Number
counting frequency
pulse shape
pulse / pause ratio
Number
counting frequency
pulse shape
pulse / pause ratio

from voltage supply
from the digital inputs
from the outputs
from PC interface,
memory
module, CL-NET,
CL-LINK
analog
digital
two CL devices
within one device
Input delay ON
Input delay OFF

0-40 V AC (sinusoidal)

> 9.5 V DC,
14-26.4 V AC
(sinusoidal) (I1-I6),
> 7 V AC (sinusoidal)
(I7,I8)
50-60 Hz
4 mA
(at 24 V AC, 50 Hz, I1-I6),
2 mA
(at 24 V AC, 50 Hz, I7,I8),
2 mA (at 24 V DC, I7, I8)

2 (I7, I8)
no
no
yes
no

-

DC voltage
0-10 V DC
0.01 V
0.01 V; 10 Bit (value 1-1023)
11.2 kq
±3 %
±2 %, ±0.12 V
20 ms
each cycle
< 1 mA
< 30 m

-

6/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type

CL-LMR.C...18DC1

Input circuit - Digital inputs

12 V DC

Number
Inputs can be used as analog inputs
Indication of operational states
Electrical isolation
from voltage supply
between digital inputs
from the outputs
from PC interface,
memory module, CL-NET,
CL-LINK
Rated operational
voltage U e
U e on „0“ signal

12
4 (I7, I8, I11, I12)
LCD-Display (if existing)
no
no
yes
no
12 V DC
4 V DC (I1-I12)

U e on „1“ signal 8 V DC (I1-I12)

Rated frequency
Input current
on „1“ signal

3.3 mA
(at 12 V DC, I1-I6, I9-I12),
1.1 mA
(at 12 V DC, I7, I8)

Time delay
from „0“ to „1“
Time delay
from „1“ to „0“
Cable length (unshielded)
Maximum cable length per input
Frequency counter

Rapid counter inputs

Cable length (shielded)
Input circuit - Analog inputs
Number
Electrical isolation

Input type
Signal range
Resolution
Input impedance
Accuracy of the
actual value
Conversion time
analog/digital
Input current
Cable length (shielded)

CL-LMR.C...18DC2
CL-LMT.C...20DC2
24 V DC

from voltage supply
from the digital inputs
from the outputs
from PC interface,
memory
module, CL-NET,
CL-LINK
analog
digital
two CL devices
within one device
Input delay ON
Input delay OFF

CL-LMR.C...18AC2

24 V AC

115 / 230 V AC
-

yes
24 V DC
24 V AC
< 5 V DC
0-6 V AC (sinusoidal)
(I1-I12, R1-R12)
> 15 V DC (I1-I6, I9, I10) > 9.5 V DC,
> 8 V DC (I7, I8, I11, I12) 14-26.4 V AC
(sinusoidal) (I1-I6, I9, I10)
> 7 V AC (sinusoidal)
(I7,I8; I11, I12)
50-60 Hz
3.3 mA
4 mA
(at 24 V DC, I1-I6, I9, I10), (at 24 V AC, 50 Hz,
2.2 mA
I1-I6, I9, I10),
(at 24 V DC, I7, I8, I11, I12) 2 mA
(at 24 V AC, 50 Hz,
I7, I8, I11, I12),
2 mA
(at 24 V DC, I7, I8, I11, I12)

debounce ON 20 ms
debounce OFF typ. 0.3 ms (I1-I6, I9, I10), typ. 0.25 ms
typ. 0.35 ms (I7, I8, I11, I12)
debounce ON 20 ms
debounce OFF typ. 0.4 ms (I1-I6, I9, I10), typ. 0.35 ms (I7, I8, I11, I12)
100 m

number
counting frequency
pulse shape
pulse / pause ratio
number
counting frequency
pulse shape
pulse / pause ratio

CL-LMR.C...18AC1

2 (I3, I4)
< 1 kHz
square-wave
1:1
2 (I1, I2)
< 1 kHz
square-wave
1:1
< 20 m

0-40 V AC (sinusoidal)
79-264 V AC
(sinusoidal)

6x0.25 mA
(at 115 V AC, 60 Hz,
I1-I6),
6x0.5 mA
(at 230 V AC, 50 Hz,
I1-I6)
2x4 mA
(at 115 V AC, 60 Hz,
I7, I8),
2x6 mA
(at 230 V AC, 50 Hz,
I7, I8),
4x0.25 mA
(at 115 V AC, 60 Hz,
I9-I12),
4x0.5 mA
(at 230 V AC, 50 Hz,
I9-I12)
80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz)
20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz)

6

80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz)
20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz)
max. 40 m,
typ. 40 m (I9, I10)
-

typ. 40 m (I1-I6, I9-I12),
typ. 100 m (I7, I8)
-

4 (I7, I8, I11, I12)
no
no
yes
no

-

DC voltage
0-10 V DC
0.01 V
0.01 V; 10 Bit (value 1-1023)
11.2 kq
±3 %
±2 %, ±0.12 V
20 ms
each cycle
< 1 mA
< 30 m

-

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/12

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type
Input circuit - Digital inputs
Number
Inputs can be used as analog inputs
Indication of operational states
Electrical isolation
from voltage supply
between digital inputs
from the outputs
from PC interface,
memory
module, CL-NET,
CL-LINK
Rated operational
voltage U e
U e on „0“ signal

12
no
no
yes
no

CL-LER.18DC2, CL-LET.20DC2
24 V DC

24 V DC
< 5 V DC (I1-I12, R1-R12)

U e on „1“ signal -

6

Rated frequency
Input current
on „1“ signal
Time delay
from „0“ to „1“

3.3 mA (at 24 V DC, R1-R12)
debounce ON 20 ms
debounce OFF typ. 0.25 ms (R1-R12)

Time delay
from „1“ to „0“

debounce ON 20 ms
debounce OFF -

Cable length (unshielded)
Maximum cable length per input

100 m
-

6/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

CL-LER.18AC2
115 / 230 V AC

0-40 V AC (sinusoidal)
79-264 V AC (sinusoidal)
50-60 Hz
12x0.25 mA (at 115 V AC, 60 Hz, R1-R12),
12x0.5 mA (at 230 V AC, 50 Hz, R1-R12)
80 ms (at 50 Hz, I1-I12, R1-R12),
66 2/3 ms (at 60 Hz, I1-I12, R1-R12)
20 ms (at 50 Hz, I1-I12, R1-R12),
16 2/3 ms (at 60 Hz, I1-I12, R1-R12)
80 ms (at 50 Hz, I1-I12, R1-R12),
66 2/3 ms (at 60 Hz, I1-I12, R1-R12)
20 ms (at 50 Hz, I1-I12, R1-R12),
16 2/3 ms (at 60 Hz, I1-I12, R1-R12)
typ. 40 m (I1-I6, I9-I12, R1-R12),
typ. 100 m (I7, I8)

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type

CL-LSR...

4
6
1
not permissible
circuit-breaker B16 or fuse 8 A (slow-acting)
from voltage supply yes
from the inputs yes
from PC interface, memory module, no
CL-NET, CL-LINK
protective separation 300 V AC
basic isolation 600 V AC
10x106 switching cycles
conventional thermal current (10 A UL) 8 A
recommended for load 12 V AC/DC > 500 mA
short-circuit proof cos j = 1; 16 A
characteristic B16 at 600 A
short-circuit proof cos j = 0,5 up to 0,7; 16 A
characteristic B16 at 900 A
Rated impulse withstand voltage U imp 6 kV
contact-coil
Rated operational voltage U e 250 V AC

Rated insulation voltage U i
Protective separation (EN
50178)
Making capacity
Breaking capacity
Incandesent lamp load
Fluorescent lamp load

Switching frequency

UL/CSA
Continuous current at 240 V
Continuous current at 24 V
AC

DC

CL-LER.2O

CL-LER...

Output circuit - Relay outputs
Number
Outputs in groups of
Parallel switching of outputs to increase capacity
Fusing of the output relay
Electrical isolation

Mechanical lifetime
Rung

CL-LMR...

2
2

6

250 V AC
between coil and contact
between two contacts
AC-15, 250 V AC, 3 A (600 ops./h)
DC13, L/R m 150 ms, 24 V DC, 1 A
(500 ops./h)
AC-15, 250 V AC, 3 A (600 ops./h)
DC13, L/R m 150 ms, 24 V DC, 1 A
(500 ops./h)
1000 W at 230/240 V AC
500 W at 115/120 V AC
10 x 58 W at 230/240 V AC
with electrical control gear
10 x 58 W at 230/240 V AC
uncompensated
1 x 58 W at 230/240 V AC
conventional compensated
mechanical operations
switching frequency
resistive load / lamp load
inductive load

300 V AC
300V AC
300.000 switching cycles
200.000 switching cycles
300.000 switching cycles
200.000 switching cycles
25.000 switching cycles
25.000 switching cycles
25.000 switching cycles
25.000 switching cycles
25.000 switching cycles
10x10 6
10 Hz
2 Hz
0.5 Hz

10 A AC
8 A DC
Utilization catagory (Control Circuit Rating B 300 Light Pilot Duty
Codes)
max. rated operational voltage 300 V AC
max. continuous thermal current cos j = 5 A
1 at B 300
max. making / breaking apparent power 3600/360 VA
(Make/Break) cos j ≠ 1 at B 300
Utilization catagory (Control Circuit Rating R 300 Light Pilot Duty
Codes)
max. rated operational voltage 300 V DC
max. continuous thermal current at R 300 1 A
max. making / breaking apparent power 28/28 VA
(Make/Break) at R 300

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/14

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type
Output circuit - Transistor outputs
Number
Rated operational voltage U e
Operational voltage range
Residual ripple
Supply current
Reverse voltage protection

CL-LST...
4
24 V DC

on „0“ signal
on „1“ signal

Electrical isolation

CL-LMT...

CL-LET...

8

20.4-28.8 V DC
m5%
typ. 9 mA / max. 16 mA typ. 18 mA / max. 32 mA
typ. 12 mA / max. 22 mA typ. 24 mA / max. 44 mA
yes (Attention: If supply voltage is reversed, applying voltage at the
outputs, causes a short circuit.)
yes
yes
-

from voltage supply
from the inputs
from PC interface, memory module,
CL-NET, CL-LINK
Rated operational current I e on„1“ signal DC
max. 0.5 A

6

Lamp load without R v

5W

Residual current on „0“ signal per channel
Max. output voltage
on „0“ signal at external load < 10 Mq
on „1“ signal at Ie = 0.5 A
Short-circuit protection
Short-circuit tripping current for R a m 10 mq
Total short-circuit current
Peak short-circuit current
Thermal tripping
Max. switching frequency with constant resistive load R L < 100 kq
(depending on active channels and their load)
Parallel connection of outputs
with resistive load, inductive load with
external
suppressor, combination within one group
number of outputs
max. total current

< 0.1 mA
2.5 V
U = Ue - 1 V
yes, thermal (analysis results from diagnosis input I16, I15; R15, R16)
0.7 A m I e m 2 A per output
8A
16 A
16 A
32 A
yes
40.000 switching cycles/h

Indication of operational states of the outputs
Inductive load1) without external suppressor
T0.95 = 1 ms,
utilization factor
R = 48 q,
duty time
L = 16 mH
max. switching frequency f = 0,5 Hz
(max. duty time = 50 %)
DC13,
utilization factor
T0.95 = 72 ms,
duty time
R = 48 q,
max. switching frequency f = 0,5 Hz
L = 1.15 H
(max. duty time = 50 %)
T0.95 = 15 ms,
utilization factor
R = 48 q,
duty time
L = 0.24 H
max. switching frequency f = 0,5 Hz
(max. duty time = 50 %)
Inductive load1) with external suppressor
demand factor
duty time
max. switching frequency
max. duty time

group 1: Q1-Q4

group 1: Q1-Q4,
group 2: Q5-Q8

group 1: S1-S4, group
2: S5-S8

max. 4
2 A (Attention! Outputs must be actuated simultaneously and for the
same length of time.)
LCD-Display (if existing)
0.25 g
100 %
1500 switching cycles
0.25 g
100 %
1500 switching cycles
0.25 g
100 %
1500 switching cycles
1g
100 %
depends on suppressor

1) For inductive loading, without external suppression of the transistor outputs, the following applies:
T0.95 = time in ms, until 95 % of the steady-state current is achieved. T0.95 3 × T0.65 = 3 × L/R.
Data transfer rate in the CL-NET network: bus lengths of 40 m and over only attainable with cables with additional cross-section and connection adapter.

6/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type

CL-LSR..., CL-LST...

General data
Dimensions (W x H x D)

Max. tightening torque
Environmental data
Ambient temperature range

rigid 0.2-4 mm 2 (22–12 AWG)
fine-strand with wire end 0.2-2.5 mm 2 (22–12 AWG)
ferrule
0.6 Nm

LCD-Display (clearly legible)
Condensation
Humidity, no condensation (IEC/EN 60068-2-30)
Air pressure (operation)
Degree of protection (IEC/EN 60529)
Vibration (IEC/EN 60068-2-6)
Shock resistance (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27)
Drop (IEC/EN 60068-2-31) height of fall
Free fall, packaged (IEC/EN 60068-2-32)
Insulation data
Overvoltage category
Pollution degree (DIN EN 60947)
Rating of air and creepage distances
Insulation resistance
Standards
Standards and directives
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
IEC/EN
electromag. field (HF radiation resistance)
IEC/EN
fast transients (Burst)
IEC/EN
powerful impulses (Surge)
IEC/EN
HF line emission
Interference suppression (EN 55011, EN 55022)
Real time clock
Back-up time
Accuracy
Repeat accuracy of the time relay
Accuracy (from value)
Resolution

operation -25...+55 °C, cold acc. to IEC 60068-2-1, heat acc. to IEC 60068-2-2
storage -40...+70 °C
0...+55 °C
avoid condensation with suitable methods
5-95 %
795-1080 hPa
IP20
10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant
acceleration 2 g)
18 Shocks
50 mm
1m

6

II
2
EN 50178, UL 508, CSA C22.2, No. 142
EN 50178
EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27

61000-4-2
61000-4-3
61000-4-4
61000-4-5

Level 3 (air discharge 8 kV, contact discharge 6 kV)
10 V/m
Level 3 (supply cable 2 kV, signal lines 2 kV)
supply cable symmetrical (AC) 2 kV,
Level 2 (supply cable symmetrical (DC) 0.5 kV)
IEC/EN 61000-4-6 10 V
class B
see diagram
typ. ±5 (±0.5 h/year)

-

±1
range „S“ 10 ms
range „M:S“ 1 s
range „H:M“ 1 min

Retention behaviour
Write cycles of retention memory (minimum)

-

200
180
160
140
120
100
80
60
40
20
0
0

-

2CDC 312 023 F0206

1.000.000 (10 6)

Buffer time (hours)

Technical diagram
Back-up time of the real time clock

CL-LER.2O
CL-LEC.CI000

71.5 mm x 90 mm x
107.5 mm x 90 mm x
35.5 mm x 90 mm x
58 mm
58 mm
58 mm
(2.81 inch x 3.54 inch x (4.23 inch x 3.54 inch x (1.40 inch x 3.54 inch x
2.28 inch)
2.28 inch)
2.28 inch)
0.2 kg (0.44 lb)
0.3 kg (0.66 lb)
0.07 kg (0.15 lb)
DIN rail (IEC/EN 60715), 35 mm or screw mounting with fixing brackets
CL-LAS.FD001 (accessories)
horizontal / vertical

Weight
Mounting
Mounting position
Electrical connection
Wire size

CL-LMR... CL-LMT..
CL-LET.., CL-LER.18..

25 ˚C
55 ˚C

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20

Operating time (years)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/16

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type
Input circuit - Supply circuit
Power failure buffering (IEC/EN 61131-2)
General data
Dimensions (W x H x D)

CL-LDD...
10 ms
with keypad:
86.5 x 86.5 x 21.5 mm (3.41 x 3.41 x 0.85 inch)
without keypad:
86.5 x 86.5 x 20 mm (3.41 x 3.41 x 0.79 inch)
0.13 kg (0.29 lb)
2 x 22.5 mm, with 2 retainers screwed
horizontal / vertical

Weight
Mounting
Mounting position
Environmental data
Ambient temperature range

operation -25...+55 °C (cold acc. to IEC 60068-2-1, heat acc. to IEC
60068-2-2)
storage -40...+70 °C
-5...+50 °C,
-10...0 °C (with backlit / continuous operation)
avoid condensation with suitable methods
5-95 %
795-1080 hPa
IP65
10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant
acceleration 2 g)
18 Shocks
50 mm
1m

LCD-Display (clearly legible)

6

Condensation
Humidity, no condensation (IEC/EN 60068-2-30)
Air pressure (operation)
Degree of protection (IEC/EN 60529)
Vibration (IEC/EN 60068-2-6)
Shock resistance (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27)
Drop (IEC/EN 60068-2-31) height of fall
Free fall, packaged (IEC/EN 60068-2-32)
Insulation data
Pollution degree (DIN EN 60947)
Rating of air and creepage distances
Insulation resistance
Standards
Standards and directives
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromag. field (HF radiation resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference suppression (EN 55011, EN 55022)

3
EN 50178, UL 508, CSA 22.2, No 142
EN 50178
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4,
IEC 60068-2-6, IEC 60068-2-27
IEC/EN
IEC/EN
IEC/EN
IEC/EN

61000-4-2
61000-4-3
61000-4-4
61000-4-5

Level 3 (air discharge 8 kV, contact discharge 6 kV)
10 V/m
Level 3 (supply cable 2 kV, signal lines 2 kV)
Level 3 (supply cable symmetrical 2 kV, CL-LDC.L...AC2)
Level 2 (0.5 kV supply cable symmetrical, CL-LDC.L...AC2)
IEC/EN 61000-4-6 10 V
class B

6/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type
Input circuit - Supply circuit
Rated operational voltage U e
Rated operational voltage tolerance
Operational voltage range
Frequency
Frequency tolerance
Residual ripple
Input current

at 24 V DC
at 115/120 V AC (60 Hz)
at 230/240 V AC (50 Hz)
Power failure buffering (IEC/EN 61131-2)
Power dissipation
at 24 V DC
at 115/120 V AC
at 230/240 V AC
Network - point-to-point connection
Number of stations
Data transfer rate
CL-LS..., CL-LM...
CL-LDD
Distance
Electrical isolation
to voltage supply
to connected device
Termination system
Network - CL-NET
Number of stations
Data transfer rate
6m
25 m
40 m
125 m
300 m
700 m
1000 m
Electrical isolation
to voltage supply
to inputs
to outputs
to PC interface,
memory module,
CL-NET, CL-LINK
Bus terminator (first and last station)
Termination system
General data
Dimensions (W x H x D)
Weight
Mounting
Mounting position
Electrical connection - Supply circuit
Wire size
fine-strand with wire
end ferrule
rigid
Electrical connection - Data cable
Wire size
fine-strand with wire
end ferrule
rigid

CL-LDC.SDC2 CL-LDC.SAC2 CL-LDC.LDC2

CL-LCD.LAC2 CL-LDC.LNDC2 CL-LDC.LNAC2

24 V DC

100-240 V AC 24 V DC

100-240 V AC 24 V DC

100-240 V AC

-15...+20 %
20.4-28.8 V DC
0 Hz
m5%
typ. 185 mA
10 ms
1.5 W
-

-15...+10 %
85-264 V AC
50/60 Hz
±5%
typ. 90 mA
typ. 60 mA

-15...+20 %
20.4-28.8 V DC
0 Hz
m5%
typ. 200 mA
-

-15...+10 %
85-264 V AC
50/60 Hz
±5%
typ. 90 mA
typ. 60 mA

-15...+20 %
20.4-28.8 V DC
0 Hz
m5%
typ. 200 mA
-

-15...+10 %
85-264 V AC
50/60 Hz
±5%
typ. 90 mA
typ. 60 mA

typ. 11 VA
typ. 15 VA

3.4 W
-

typ. 11 VA
typ. 15 VA

3.4 W
-

typ. 11 VA
typ. 15 VA

1
9.6 kBaud
19.2 kBaud
max. 5 m
yes
yes
spring-type terminal

-

max. 1
-

-

-

6

max. 8
1000 kBit/s
500 kBit/s
250 kBit/s
125 kBit/s
50 kBit/s
20 kBit/s
10 kBit/s
yes
yes
yes
yes
yes
RJ45, 8 pole

75 x 58 x 36.2 mm
(2.95 x 2.28 x 1.43 inch)
0.164 kg (0.36 lb)
plugged onto CL-LDD

107.5 x 90 x 30 mm
(4.23 x 3.54 x 1.18 inch)
0.145 kg (0.32 lb)
plugged onto CL-LDD or on DIN rail (IEC/EN 60715)

0.2 mm 2 / 2.5 mm 2 (24-12 AWG)
0.2 mm 2 / 4 mm 2 (24-12 AWG)
0.08 mm 2 / 1.5 mm 2 (28-12
AWG)
0.08 mm 2 / 2.5 mm 2 (28-12
AWG)

-

0.2 mm 2 / 2.5 mm 2 (24-12
AWG)
0.2 mm 2 / 4 mm 2 (24-12 AWG)

Environmental data
Ambient temperature range

operation -25...+55 °C (cold acc. to IEC 60068-2-1, heat acc. to IEC 60068-2-2)
storage -40...+70 °C
Condensation
avoid condensation with suitable methods
Humidity, no condensation (IEC/EN 60068-2-30)
5-95 %
Air pressure (operation)
795-1080 hPa
Degree of protection (IEC/EN 60529)
IP20
Vibration (IEC/EN 60068-2-6)
10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant acceleration 2 g)

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/18

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type

CL-LDC.

Shock (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27)
Drop (IEC/EN 60068-2-31) height of fall
Free fall, packaged (IEC/EN 60068-2-32)
Insulation data
Degree of protection (DIN EN 60947)
Rating of air and creepage distances
Isolation resistance
Standards
Standards and directives
Electromagnetical compatibility
Interference immunity
electrostatic discharge (ESD)
electromag. field (HF radiation
resistance)
fast transients (Burst)
powerful impulses (Surge)

CL-LDC.

CL-LCD.

CL-LDC.

CL-LDC.

SAC2

LDC2

LAC2

LNDC2

LNAC2

2
EN 50178, UL 508, CSA 22.2, No 142
EN 50178
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, IEC 60068-2-6, IEC 600682-27
Level 3 (air discharge 8 kV, contact discharge 6 kV)
10 V/m

Technical diagram
Back-up time of the real time clock

200
180
160
140
120
100
80
60
40
20
0
0

2CDC 312 023 F0206

Level 3 (supply cable 2 kV, signal lines 2 kV)
Level 3 (supply cable symmetrical 2 kV, CL-LDC.L...AC2)
Level 2 (1 kV supply cable
Level 2 (0.5 kV supply cable symmetrical, CL-LDC.L...AC2)
symmetrical)
HF line emission
IEC/EN 61000-4-6 10 V
Interference suppression (EN 55011, EN 55022)
class B
Real time clock
Back-up time
see diagram
Accuracy
typ. ± 5 s/day (± 0,5 h/year)
Repeat accuracy of the time relay
Accuracy (from value)
± 0.02 %
Resolution
range „S“ 5 ms
range „M:S“ 1s
range „H:M“ 1 min
Retention behaviour
Write cycles of retention memory (minimum)
1010 (read/ write cycles)

Buffer time (hours)

6

IEC/EN 61000-4-2
IEC/EN 610004-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5

CL-LDC.

SDC2
18 Shocks
50 mm
1m

25 ˚C
55 ˚C

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20

Operating time (years)

6/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type
Input circuit - Digital inputs
Number
Inputs can be used as analog inputs
Indication of operational states
Electrical isolation

Rated operational voltage U e

CL-LD...16DC2

from supply voltage
from digital inputs
from the outputs
from PC interface, memory module,
CL-NET, CL-LINK

12
4 (I7, I8, I11, I12)
no
no
yes
yes

24 V DC

CL-LD...17DC2

Rated frequency
Input current on „1“ signal

0 Hz
3.3 mA (at 24 V DC, I1-I6, I9, I10),
2.2 mA (at 24 V DC, I7, I8, I11, I12)
debounce ON 20 ms
debounce OFF typ. 0.1 ms (I1-I4), typ. 0.25 ms (I5-I12)

Time delay
from „1“ to „0“
Cable length (unshielded)
Maximum cable length per input
Frequency counter

Incremental counter

Rapid counter inputs

Cable length (shielded)
Input circuit - Analog inputs
Number
Electrical isolation

Input type
Signal range
Resolution
Input impedance
Accuracy of the actual value
Conversion time analog/digital
Input current
Cable length (shielded)

LCD-Display (if existing)

24 V DC
U e on „0“ signal < 5 V DC (I1-I6, I9, I10), < 8 V DC (I7, I8, I11, I12) 0-40 V AC (sinusoidal)
U e on „1“ signal > 15 V DC (I1-I6, I9, I10), > 8 V DC (I7, I8, I11, I12)

Time delay from „0“ to „1“

CL-LDR.16AC2
115/230 V

debounce ON 20 ms
debounce OFF typ. 0.1 ms (I1-I4), typ. 0.4 ms (I5, I6, I9, I10),
typ. 0.2 ms (I7, I8, I11, I12)
100 m
number 4 (I1, I2, I3, I4)
counting frequency < 3 kHz
pulse shape square-wave
pulse / pause ratio 1:1
number 2 (I1 + I2, I3 + I4)
counting frequency < 3 kHz
pulse shape square-wave
signal offset 90°
pulse / pause ratio 1:1
number 4 (I1, I2, I3, I4)
counting frequency < 3 kHz
pulse shape square-wave
pulse / pause ratio 1:1
< 20 m

to voltage supply
to digital inputs
to outputs
to PC interface, memory modul,
CL-NET, CL-LINK

4 (I7, I8, I11, I12)
no
no
yes
yes

DC voltage
0-10 V DC
analog 0.01 V
digital 0.01 V; 10 Bit (value 0-1023)
11.2 kq
two CL-LD... ± 3 %
devices
within one device ± 2 %
each cycle
< 1 mA
< 30 m

79-264 V AC
(sinusoidal)
50-60 Hz
12x0.2 mA (at 115 V AC,
60 Hz, I1-I12),
12x0.5 mA (at 230 V
AC, 50 Hz, I1-I12)
10 ms (at 50 Hz),
100 ms (at 60 Hz)
10 ms (at 50 Hz),
100 ms (at 60 Hz)
10 ms (at 50 Hz),
100 ms (at 60 Hz)
10 ms (at 50 Hz),
100 ms (at 60 Hz)
typ. 60 m
-

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/20

6

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type
Output circuit - Analog outputs
Number
Electrical separation

CL-LD...16DC2
from voltage supply
from the digital inputs
from the digital outputs
from PC interface, memory
module, CL-NET, CL-LINK

Output type
Signal range
Max. output current
Burden resistance
Overload and short-circuit protection
Resolution

analog
digital

Setting time
Accuracy

6

-25...+55 °C
25 °C

Conversion time
General data
Dimensions (W x H x D)
Weight
Mounting
Mounting position
Electrical connection
Wire size
Electrical connection - Data cable
Wire size

CL-LD...17DC2

CL-LDR.16AC2

-

1
no
no
yes
yes

-

-

DC voltage
0-10 V DC
0.01 A
1 kq
yes
0.01 V DC
10 Bit, (value: 0-1023)
100 ms
2%
1%
each CPU cycle

-

CL-LDR: 89 x 90 x 44 mm (3.5 x 3.54 x 1.73 inch)
89 x 90 x 44 mm
CL-LDT (build-in): 89 x 90 x 25 mm (3.5 x 3.54 x 0.98 (3.5 x 3.54 x 1.73 inch)
inch)
CL-LDR: 0.15 kg (0.33 lb) / CL-LDT: 014 kg (0.31 lb)
0.15 kg (0.33 lb)
snap-on power supply unit
horizontal / vertical
fine-strand with wire end ferrule 0.2 mm 2 / 2.5 mm 2 (24-12 AWG)
rigid 0.2 mm 2 / 4 mm 2 (24-12 AWG)
fine-strand with wire end ferrule 0.08 mm 2 / 1.5 mm 2 (28-12 AWG)
rigid 0.08 mm 2 / 2.5 mm 2 (28-12 AWG)

Environmental data
Ambient temperature range
Condensation
Humidity, no condensation (IEC/EN 60068-2-30)
Atmospheric pressure (operation)
Degree of protection (IEC/EN 60529)
Vibration (IEC/EN 60068-2-6)
Shock (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27)
Drop (IEC/EN 60068-2-31) height of fall
Free fall, packaged (IEC/EN 60068-2-32)
Insulation data
Pollution degree
Rating of air and creepage distances
Isolation resistance
Standards
Standards and directives
Electromagnetic compatibility
electrostatic discharge (ESD)
electromag. field (HF radiation res.)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference suppression (EN 55011, EN 55022)

operation -25...+55 °C (cold acc. to IEC 60068-2-1, heat acc. to IEC 60068-2-2)
storage -40...+70 °C
avoid condensation with suitable methods
5-95 %
795-1080 hPa
IP20
10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant
acceleration 2 g)
18 Shocks
50 mm
1m
2
EN 50178, UL 508, CSA C22.2, No. 142
EN 50178
EN 61000-6-1/-2/-3/-4, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5

Level 3 (air discharge 8 kV, contact discharge 6 kV)
10 V/m
Level 3 (supply cable 2 kV, signal cable 2 kV)
2 kV (supply cable symmetrical),
Level 2 (0.5 kV supply cable symmetrical)
IEC/EN 61000-4-6 10 V
class B

6/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type
Output circuit - Relay outputs
Number
Outputs in groups of
Parallel switching of outputs to increase capacity
Fusing of the output relay
Electrical isolation

Mechanical lifetime
Rung

CL-LDR...

4
not permissible
circuit-breaker B16 or fuse 8 A (slow-acting)
from voltage supply yes
from the inputs yes
from PC interface, memory module, CL-NET, yes
CL-LINK
protective separation 300 V AC
Basic isolation 600 V AC
10x10 6 switching cycles
conventional thermal current (10 A UL) 8 A
recommended load 12 V AC/DC > 500 mA
short-circuit proof cos j = 1; 16 A
characteristic B16 at 600 A
short-circuit proof cos j = 0.5 up to 0.7; 16 A
characteristic B16 at 900 A
Rated impulse withstand voltage U imp contact-coil 6 kV

6

Rated operational voltage U e 250 V AC
Rated insulation voltage U i
Protective separation (EN 50178)
Making capacity
Breaking capacity
Incandesent lamp load
Fluorescent lamp load

Switching frequency

UL/CSA
Continuous current at 240 V
Continuous current at 24 V
AC

DC

250 V AC
between coil and contact
between two contacts
AC-15, 250 V AC, 3 A (600 ops./h)
DC13, L/R m 150 ms, 24 V DC, 1 A (500 ops./h)
AC-15, 250 V AC, 3 A (600 ops./h)
DC13, L/R m 150 ms, 24 V DC, 1 A (500 ops/h)
1000 W at 230/240 V AC
500 W at 115/120 V AC
10 x 58 W at 230/240 V AC
with electrical control gear
10 x 58 W at 230/240 V AC
uncompensated
1 x 58 W at 230/240 V AC
conventional compensated
mechanical operations
switching frequency
resistive load / lamp load
inductive load

Utilization category (Control Circuit Rating Codes)
max. rated operational voltage
max. continuous thermal current cos j = 1 at B 300
max. making / breaking apparent power
(Make/Break) cos j ≠ 1 at B 300
Utilization category (Control Circuit Rating Codes)
max. rated operational voltage
max. continuous thermal current at R 300
max. making / breaking apparent power
(Make/Break) at R 300

300 V AC
300V AC
300.000 switching cycles
200.000 switching cycles
300.000 switching cycles
200.000 switching cycles
25.000 switching cycles
25.000 switching cycles
25.000 switching cycles
25.000 switching cycles
25.000 switching cycles
10x10 6
10 Hz
2 Hz
0.5 Hz
10 A AC
8 A DC
B 300 Light Pilot Duty
300 V AC
5A
3600/360 VA
R 300 Light Pilot Duty
300 V DC
1A
28/28 VA

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/22

Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type

CL-LDT...

Output circuit - Transistor outputs
Number
Rated operational voltage U e

4
24 V DC

Operational voltage range
Residual ripple
Supply current

on „0“ signal
on „1“ signal

Reverse voltage protection
Electrical isolation

6

from voltage supply
from the inputs
from PC interface, memory module,
CL-NET, CL-LINK

20.4-28.8 V DC
typ. 18 mA / max. 32 mA
typ. 24 mA / max. 44 mA
yes (Attention: If supply voltage is reversed,
applying voltage at the outputs, causes a short circuit.)
yes
yes
yes

Rated operational current I e on„1“ signal DC

max. 0.5 A

Lamp load without R v

5 W (Q1-Q4)

Residual current on „0“ signal per channel
Max. output voltage

< 0.1 mA
on „0“ signal at external load < 10 Mq 2.5 V
on „1“ signal at I e = 0.5 A U = U e - 1 V

Short-circuit protection
Short-circuit tripping current for R a m 10 mq
Total short-circuit current
Peak short-circuit current
Thermal tripping
Max. switching frequency with constant resistive load R L < 100 kq (depending on
active channels and their load)
Parallel connection of outputs
with resistive load, inductive load with external
suppressor, combination within one group
number of outputs
max. total current
Indication of operational states of the outputs
Inductive load1) without external suppressor
T0.95 = 1 ms,
R = 48 q,
L = 16 mH
DC13,
T0.95 = 72 ms,
R = 48 q,
L = 1.15 H
T0.95 = 15 ms,
R = 48 q,
L = 0.24 H
Inductive load1) with external suppressor

1)

utilization factor
duty time
max. switching frequency f = 0,5 Hz
(max. duty time = 50 %)
utilization factor
duty time
max. switching frequency f = 0,5 Hz
(max. duty time = 50 %)
utilization factor
duty time
max. switching frequency f = 0,5 Hz
(max. duty time = 50 %)

thermal (Q1-Q4), (analysis results from diagnosis input I16)
0.7 A m I e m 2 A per output
8A
16 A
yes
40.000 switching cycles/h
group 1: Q1-Q4
max. 4
2 A (Attention! Outputs must be actuated simultaneously
and for the same length of time.)
LCD-Display (if existing)
0.25 g
100 %
1500 switching cycles
0.25 g
100 %
1500 switching cycles
0.25 g
100 %
1500 switching cycles

demand factor 1 g
duty time 100 %
max. switching frequency max. duty time depends on suppressor

For inductive loading, without external suppression of the transistor outputs, the following applies:
T0.95 = time in ms, until 95 % of the steady-state current is achieved. T0.95 3 × T0.65 = 3 × L/R.

Data transfer rate in the CL-NET network: bus lengths of 40 m and over only attainable with cables with additional cross-section and connection adapter.

6/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010

Logic relays
Dimensional drawings

Dimensional drawings

dimensions in mm

CL-LSR, CL-LST
10.75

CL-LMR, CL-LMT
75

16.25

50

CL-LER.2O
7.5

16.25

56.5
58

47.5
56.5
58

45

110

90
M4

102

45

90

110

4.5
107.5

2CDC 312 013 F0b06

47.5
71.5

2CDC 312 012 F0b06

4.5

M4
35.75

102

45
2CDC 312 011 F0b06

90

102

110

M4

4.5
7.5

47.5
56.5

35.5

58

6

CL-LDC.S..

CL-LDD.K + CL-LDC.L.. +
(CL-LDR or CL-LDT)

58
75

28.25

30

20

28.25

62
86.5

13.7

2CDC 312 018 F0b06

86.5

29.3

36.2
65.5

2CDC 312 015 F0b06

90

30

86.5

32

86.5

22.3

17

CL-LDD

107.5

88.2
20

43.2
33.7

88.1

19

25

2CDC 312 014 F0b06

2CDC 312 016 F0b06

90

CL-LDR, CL-LDT

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB

6/24

Index
Alphanumerical
Type

7

Page

Type

Page

Type

Page

Type

Page

Numbers
A

CC-E RTD/I.................................. 4/9

CC-E/TC.................................... 4/10

CL-LEC.CI000.............................. 6/7

CC-E RTD/I.................................. 4/9

CC-U/I....................................... 4/21

CL-LER.18AC2............................. 6/7

ADP.01.. ..................................... 1/40

CC-E RTD/I.................................. 4/9

CC-U/I....................................... 4/21

CL-LER.18DC2............................ 6/7

ADP.01.. ..................................... 1/40

CC-E RTD/I.................................. 4/9

CC-U/RTD................................. 4/21

CL-LER.2O.................................. 6/7

ADP.01.. ................................... 2/130

CC-E RTD/I.................................. 4/9

CC-U/RTD................................. 4/21

CL-LET.20DC2............................. 6/7

ADP.01.. ..................................... 4/22

CC-E RTD/I.................................. 4/9

CC-U/RTDR............................... 4/21

CL-LMR.C18AC1......................... 6/7

ADP.02.. ................................... 2/130

CC-E RTD/I.................................. 4/9

CC-U/RTDR............................... 4/21

CL-LMR.C18AC2......................... 6/7

B

CC-E RTD/I.................................. 4/9

CC-U/STD.................................. 4/21

CL-LMR.C18DC1......................... 6/7

BADH V0................................... 5/47

CC-E RTD/I.................................. 4/9

CC-U/STD.................................. 4/21

CL-LMR.C18DC2......................... 6/7

BADL V0.................................... 5/47

CC-E RTD/I.................................. 4/9

CC-U/STDR............................... 4/21

CL-LMR.CX18AC1....................... 6/7

BAM2 V0................................... 5/47

CC-E RTD/I.................................. 4/9

CC-U/STDR............................... 4/21

CL-LMR.CX18AC2....................... 6/7

BJ 612-10.. ................................ 5/36

CC-E RTD/I.................................. 4/9

CC-U/TC.................................... 4/21

CL-LMR.CX18DC1....................... 6/7

BJ 612-10.. ................................ 5/47

CC-E RTD/I.................................. 4/9

CC-U/TC.................................... 4/21

CL-LMR.CX18DC2....................... 6/7

BJ 612-20.. ................................ 5/36

CC-E RTD/I.................................. 4/9

CC-U/TCR................................. 4/21

CL-LMT.C20DC2.......................... 6/7

BJ 612-20.. ................................ 5/47

CC-E RTD/V. . ............................... 4/9

CC-U/TCR................................. 4/21

CL-LMT.CX20DC2........................ 6/7

C

CC-E RTD/V. . ............................... 4/9

CC-U/V...................................... 4/21

CL-LSR.12AC2............................ 6/6

C512-24.................................. 2/104

CC-E RTD/V. . ............................... 4/9

CC-U/V...................................... 4/21

CL-LSR.12DC2............................ 6/6

C512-D. . .................................. 2/104

CC-E RTD/V. . ............................... 4/9

CL-LAD.FD001............................. 6/9

CL-LSR.C12AC1.......................... 6/6

C512-E.................................... 2/104

CC-E RTD/V. . ............................... 4/9

CL-LAD.FD002............................. 6/9

CL-LSR.C12AC2.......................... 6/6

C512-W................................... 2/104

CC-E RTD/V. . ............................... 4/9

CL-LAD.FD011............................. 6/9

CL-LSR.C12DC1.......................... 6/6

C513-D. . .................................. 2/104

CC-E RTD/V. . ............................... 4/9

CL-LAD.MD004............................ 6/9

CL-LSR.C12DC2.......................... 6/6

C513-E.................................... 2/104

CC-E RTD/V. . ............................... 4/9

CL-LAD.TK001............................. 6/9

CL-LSR.CX12AC1........................ 6/6

C513-W................................... 2/104

CC-E TC/I.................................. 4/10

CL-LAD.TK002............................. 6/9

CL-LSR.CX12AC2........................ 6/6

CC-E I/I. . ...................................... 4/8

CC-E TC/I.................................. 4/10

CL-LAD.TK003............................. 6/9

CL-LSR.CX12DC1........................ 6/6

CC-E I/I. . ...................................... 4/8

CC-E TC/I.................................. 4/10

CL-LAD.TK004............................. 6/9

CL-LSR.CX12DC2........................ 6/6

CC-E I/I. . ...................................... 4/8

CC-E TC/I.................................. 4/10

CL-LAD.TK005............................. 6/9

CL-LST.C12DC2........................... 6/6

CC-E I/I. . ...................................... 4/8

CC-E TC/I.................................. 4/10

CL-LAD.TK006............................. 6/9

CL-LST.CX12DC2......................... 6/6

CC-E I/I. . ...................................... 4/8

CC-E TC/I.................................. 4/10

CL-LAD.TK007............................. 6/8

CM-AH-3................................. 2/116

CC-E I/I. . ...................................... 4/8

CC-E TC/I.................................. 4/10

CL-LAD.TK009............................. 6/9

CM-CT 100/1........................... 2/131

CC-E I/I. . ...................................... 4/8

CC-E TC/I.................................. 4/10

CL-LAD.TK011............................. 6/9

CM-CT 100/5........................... 2/131

CC-E I/I. . ...................................... 4/8

CC-E TC/V................................. 4/10

CL-LAS.FD001............................. 6/8

CM-CT 150/1........................... 2/131

CC-E I/I-1.................................... 4/8

CC-E TC/V................................. 4/10

CL-LAS.MD003............................ 6/8

CM-CT 150/5........................... 2/131

CC-E I/I-2.................................... 4/8

CC-E TC/V................................. 4/10

CL-LAS.PS002............................. 6/8

CM-CT 200/1........................... 2/131

CC-E I/V...................................... 4/8

CC-E TC/V................................. 4/10

CL-LAS.TK001............................. 6/8

CM-CT 200/5........................... 2/131

CC-E I/V...................................... 4/8

CC-E V/I...................................... 4/8

CL-LAS.TK002............................. 6/8

CM-CT 300/1........................... 2/131

CC-E IAC/I................................. 4/11

CC-E V/I...................................... 4/8

CL-LAS.TK011............................. 6/8

CM-CT 300/5........................... 2/131

CC-E IAC/I................................. 4/11

CC-E V/I...................................... 4/8

CL-LDC.LAC2.............................. 6/9

CM-CT 400/1........................... 2/131

CC-E IAC/I................................. 4/11

CC-E V/I...................................... 4/8

CL-LDC.LDC2.............................. 6/9

CM-CT 400/5........................... 2/131

CC-E IAC/I................................. 4/11

CC-E V/V..................................... 4/8

CL-LDC.LNAC2............................ 6/9

CM-CT 50/1............................. 2/131

CC-E IAC/ILPO.. ......................... 4/11

CC-E V/V..................................... 4/8

CL-LDC.LNDC2............................ 6/9

CM-CT 50/5............................. 2/131

CC-E IAC/V................................ 4/11

CC-E V/V..................................... 4/8

CL-LDC.SAC2.............................. 6/6

CM-CT 500/1........................... 2/131

CC-E IAC/V................................ 4/11

CC-E V/V..................................... 4/8

CL-LDC.SDC2.............................. 6/6

CM-CT 500/5........................... 2/131

CC-E IDC/I................................. 4/11

CC-E V/V..................................... 4/8

CL-LDD.K.................................... 6/6

CM-CT 600/1........................... 2/131

CC-E IDC/I................................. 4/11

CC-E V/V..................................... 4/8

CL-LDD.K.................................... 6/9

CM-CT 600/5........................... 2/131

CC-E IDC/I................................. 4/11

CC-E/I....................................... 4/11

CL-LDD.XK.................................. 6/6

CM-CT 75/1............................. 2/131

CC-E IDC/I................................. 4/11

CC-E/I....................................... 4/11

CL-LDD.XK.................................. 6/9

CM-CT 75/5............................. 2/131

CC-E IDC/V.. .............................. 4/11

CC-E/RTD. . .................................. 4/9

CL-LDR.16AC2............................ 6/9

CM-CT A.................................. 2/131

CC-E IDC/V.. .............................. 4/11

CC-E/RTD. . .................................. 4/9

CL-LDR.16DC2............................ 6/9

CM-EFS.2P................................ 2/16

CC-E RTD/I.................................. 4/9

CC-E/STD.................................... 4/8

CL-LDR.17DC2............................ 6/9

CM-EFS.2S................................ 2/16

CC-E RTD/I.................................. 4/9

CC-E/STD.................................... 4/8

CL-LDT.16DC2............................. 6/9

CM-ENE MAX........................... 2/115

CC-E/TC.................................... 4/10

CL-LDT.17DC2............................. 6/9

CM-ENE MAX........................... 2/115

2/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Index
Alphanumerical
Type

Page

Type

Page

Type

Page

Type

Page

CM-ENE MAX.. ......................... 2/115

CM-LWN.................................... 2/76

CM-PAS.41S.............................. 2/33

CM-TCS.21P ........................... 2/104

CM-ENE MIN.. .......................... 2/115

CM-LWN.................................... 2/76

CM-PBE..................................... 2/33

CM-TCS.21S ........................... 2/104

CM-ENE MIN.. .......................... 2/115

CM-LWN.................................... 2/76

CM-PBE..................................... 2/33

CM-TCS.22P ........................... 2/104

CM-ENE MIN.. .......................... 2/115

CM-LWN.................................... 2/76

CM-PFE..................................... 2/33

CM-TCS.22S ........................... 2/104

CM-ENN.................................. 2/115

CM-LWN.................................... 2/76

CM-PFS.P.................................. 2/33

CM-TCS.23P ........................... 2/104

CM-ENN.................................. 2/115

CM-MPN.52P. . ........................... 2/34

CM-PFS.S ................................. 2/33

CM-TCS.23S ........................... 2/104

CM-ENN.................................. 2/115

CM-MPN.52S. . ........................... 2/34

CM-PSS.31P.............................. 2/33

CM-UFD.M22............................. 2/54

CM-ENN.................................. 2/115

CM-MPN.62P. . ........................... 2/34

CM-PSS.31S.............................. 2/33

CM-UFD.M31............................. 2/54

CM-ENS.................................. 2/115

CM-MPN.62S. . ........................... 2/34

CM-PSS.41P.............................. 2/33

CM-UFD.M33............................. 2/54

CM-ENS.................................. 2/115

CM-MPN.72P. . ........................... 2/34

CM-PSS.41S.............................. 2/33

COV.01...................................... 1/40

CM-ENS.................................. 2/115

CM-MPN.72S. . ........................... 2/34

CM-PVE..................................... 2/33

COV.01.................................... 2/130

CM-ENS.................................. 2/115

CM-MPS.11P............................. 2/34

CM-PVE..................................... 2/33

COV.01...................................... 4/22

CM-ENS UP/DOWN.. ................ 2/115

CM-MPS.11S............................. 2/34

CM-PVS.31P.............................. 2/33

COV.02.................................... 2/130

CM-ENS UP/DOWN.. ................ 2/115

CM-MPS.21P............................. 2/34

CM-PVS.31S.............................. 2/33

COV.11...................................... 1/40

CM-ENS UP/DOWN.. ................ 2/115

CM-MPS.21S............................. 2/34

CM-PVS.41P.............................. 2/33

COV.11.................................... 2/130

CM-ESS.1P.. .............................. 2/16

CM-MPS.23P............................. 2/34

CM-PVS.41S.............................. 2/33

COV.12.................................... 2/130

CM-ESS.1P.. .............................. 2/16

CM-MPS.23S............................. 2/34

CM-PVS.81P.............................. 2/33

CP-A CM................................... 3/51

CM-ESS.1P.. .............................. 2/16

CM-MPS.31P............................. 2/34

CM-PVS.81S.............................. 2/33

CP-A RU.................................... 3/51

CM-ESS.1S.. .............................. 2/16

CM-MPS.31S............................. 2/34

CM-SE-1000............................ 2/116

CP-ASI/2.8................................. 3/60

CM-ESS.1S.. .............................. 2/16

CM-MPS.41P............................. 2/34

CM-SE-300.............................. 2/116

CP-ASI/4.0................................. 3/60

CM-ESS.1S.. .............................. 2/16

CM-MPS.41S............................. 2/34

CM-SE-600.............................. 2/116

CP-ASI/4.0 DC/DC..................... 3/60

CM-ESS.2P.. .............................. 2/16

CM-MPS.43P............................. 2/34

CM-SFS.21P.............................. 2/15

CP-ASI/8.0................................. 3/60

CM-ESS.2P.. .............................. 2/16

CM-MPS.43S............................. 2/34

CM-SFS.21S.............................. 2/15

CP-B 24/10.0............................. 3/68

CM-ESS.2P.. .............................. 2/16

CM-MSE.................................... 2/90

CM-SFS.22S.............................. 2/15

CP-B 24/20.0............................. 3/68

CM-ESS.2S.. .............................. 2/16

CM-MSE.................................... 2/90

CM-SRS.11P.............................. 2/15

CP-B 24/3.0............................... 3/68

CM-ESS.2S.. .............................. 2/16

CM-MSE.................................... 2/90

CM-SRS.11P.............................. 2/15

CP-B EXT.2................................ 3/68

CM-ESS.2S.. .............................. 2/16

CM-MSS.11P............................. 2/90

CM-SRS.11P.............................. 2/15

CP-C 24/10.0............................. 3/45

CM-ESS.MP.. ............................. 2/16

CM-MSS.11S............................. 2/90

CM-SRS.11S.............................. 2/15

CP-C 24/20.0............................. 3/45

CM-ESS.MS.. ............................. 2/16

CM-MSS.12P............................. 2/90

CM-SRS.11S.............................. 2/15

CP-C 24/5.0............................... 3/45

CM-GM-1.. ............................... 2/116

CM-MSS.12S............................. 2/90

CM-SRS.11S.............................. 2/15

CP-C MM................................... 3/45

CM-HE. . ................................... 2/116

CM-MSS.13P............................. 2/90

CM-SRS.12S.............................. 2/15

CP-D 12/0.83............................. 3/10

CM-IVN.P.. ................................. 2/66

CM-MSS.13S............................. 2/90

CM-SRS.12S.............................. 2/15

CP-D 12/2.1............................... 3/10

CM-IVN.S.. ................................. 2/66

CM-MSS.21P............................. 2/90

CM-SRS.12S.............................. 2/15

CP-D 24/0.42............................. 3/10

CM-IWN.1P.. .............................. 2/66

CM-MSS.21S............................. 2/90

CM-SRS.21P.............................. 2/15

CP-D 24/0.42............................... 6/8

CM-IWN.1S.. .............................. 2/66

CM-MSS.22P............................. 2/90

CM-SRS.21P.............................. 2/15

CP-D 24/1.3............................... 3/10

CM-IWN.4P.. .............................. 2/66

CM-MSS.22S............................. 2/90

CM-SRS.21P.............................. 2/15

CP-D 24/1.3................................. 6/8

CM-IWN.4S.. .............................. 2/66

CM-MSS.23P............................. 2/90

CM-SRS.21S.............................. 2/15

CP-D 24/2.5............................... 3/10

CM-IWN.5P.. .............................. 2/66

CM-MSS.23S............................. 2/90

CM-SRS.21S.............................. 2/15

CP-D 24/4.2............................... 3/10

CM-IWN.5S.. .............................. 2/66

CM-MSS.31P............................. 2/90

CM-SRS.21S.............................. 2/15

CP-D RU.................................... 3/51

CM-IWN.6P.. .............................. 2/66

CM-MSS.31S............................. 2/90

CM-SRS.22S.............................. 2/15

CP-E 12/10.0............................. 3/20

CM-IWN.6S.. .............................. 2/66

CM-MSS.32P............................. 2/90

CM-SRS.22S.............................. 2/15

CP-E 12/2.5............................... 3/20

CM-IWS.1P................................ 2/66

CM-MSS.32S............................. 2/90

CM-SRS.22S.............................. 2/15

CP-E 24/0.75............................. 3/20

CM-IWS.1S................................ 2/66

CM-MSS.33P............................. 2/90

CM-SRS.M1P............................. 2/15

CP-E 24/1.25............................. 3/20

CM-IWS.2P................................ 2/66

CM-MSS.33S............................. 2/90

CM-SRS.M1S............................. 2/15

CP-E 24/10.0............................. 3/20

CM-IWS.2S................................ 2/66

CM-MSS.41P............................. 2/90

CM-SRS.M2S............................. 2/15

CP-E 24/2.5............................... 3/20

CM-KH-3................................. 2/116

CM-MSS.41S............................. 2/90

CM-TCS.11P ........................... 2/104

CP-E 24/20.0............................. 3/20

CM-LWN.................................... 2/76

CM-MSS.51P............................. 2/90

CM-TCS.11S ........................... 2/104

CP-E 24/5.0............................... 3/20

CM-LWN.................................... 2/76

CM-MSS.51S............................. 2/90

CM-TCS.12P ........................... 2/104

CP-E 48/0.62............................. 3/20

CM-LWN.................................... 2/76

CM-PAS.31P.............................. 2/33

CM-TCS.12S ........................... 2/104

CP-E 48/1.25............................. 3/20

CM-LWN.................................... 2/76

CM-PAS.31S.............................. 2/33

CM-TCS.13P ........................... 2/104

CP-E 48/10.0............................. 3/20

CM-LWN.................................... 2/76

CM-PAS.41P.............................. 2/33

CM-TCS.13S ........................... 2/104

CP-E 48/5.0............................... 3/20

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/2

7

Index
Alphanumerical
Type

7

Page

Type

Page

Type

Page

Type

Page

CP-E 5/3.0.. ............................... 3/20

CR-M048DC4LG........................ 5/11

CR-M230AC4L........................... 5/11

CR-P048DC1............................... 5/9

CP-RUD. . ................................... 3/51

CR-M060AC3. . ........................... 5/10

CR-M230AC4LG........................ 5/11

CR-P048DC2............................... 5/9

CP-S 24/10.0............................. 3/45

CR-M060DC2............................ 5/10

CR-M2LC................................... 5/11

CR-P110AC1............................... 5/9

CP-S 24/20.0............................. 3/45

CR-M060DC2L. . ......................... 5/11

CR-M2LS................................... 5/11

CR-P110AC2............................... 5/9

CP-S 24/5.0.. ............................. 3/45

CR-M060DC3............................ 5/10

CR-M2SF................................... 5/11

CR-P110AC2G............................. 5/9

CP-T 24/10.0............................. 3/34

CR-M060DC3L. . ......................... 5/11

CR-M2SS................................... 5/11

CR-P110DC1............................... 5/9

CP-T 24/20.0............................. 3/34

CR-M060DC4............................ 5/10

CR-M3LS................................... 5/11

CR-P110DC2............................... 5/9

CP-T 24/40.0............................. 3/34

CR-M060DC4L. . ......................... 5/11

CR-M3SS................................... 5/11

CR-P120AC1............................... 5/9

CP-T 24/5.0............................... 3/34

CR-M060DC4LG........................ 5/11

CR-M4LC................................... 5/11

CR-P120AC2............................... 5/9

CP-T 48/10.0............................. 3/34

CR-M110AC2. . ........................... 5/10

CR-M4LS................................... 5/11

CR-P230AC1............................... 5/9

CP-T 48/20.0............................. 3/34

CR-M110AC2L. . ......................... 5/11

CR-M4SF................................... 5/11

CR-P230AC2............................... 5/9

CP-T 48/5.0............................... 3/34

CR-M110AC3. . ........................... 5/10

CR-M4SS................................... 5/11

CR-P230AC2G............................. 5/9

CR-M012DC2............................ 5/10

CR-M110AC3L. . ......................... 5/11

CR-MH...................................... 5/11

CR-PH......................................... 5/9

CR-M012DC2L.. ......................... 5/11

CR-M110AC4. . ........................... 5/10

CR-MH1.................................... 5/11

CR-PJ.......................................... 5/9

CR-M012DC3............................ 5/10

CR-M110AC4G.......................... 5/11

CR-MJ....................................... 5/11

CR-PLC....................................... 5/9

CR-M012DC3L.. ......................... 5/11

CR-M110AC4L. . ......................... 5/11

CR-MM...................................... 5/11

CR-PLS....................................... 5/9

CR-M012DC4............................ 5/10

CR-M110AC4LG........................ 5/11

CR-P/M 22................................. 5/12

CR-PLSx...................................... 5/9

CR-M012DC4L.. ......................... 5/11

CR-M110DC2............................ 5/10

CR-P/M 42................................. 5/12

CR-PM......................................... 5/9

CR-M012DC4LDG.. .................... 5/11

CR-M110DC2L. . ......................... 5/11

CR-P/M 42B.............................. 5/12

CR-PSS....................................... 5/9

CR-M012DC4LG........................ 5/11

CR-M110DC3............................ 5/10

CR-P/M 42BV............................ 5/12

CR-S005VDC1R........................... 5/8

CR-M024AC2.. ........................... 5/10

CR-M110DC3L. . ......................... 5/11

CR-P/M 42C.............................. 5/12

CR-S005VDC1RG........................ 5/8

CR-M024AC2L.. ......................... 5/11

CR-M110DC4............................ 5/10

CR-P/M 42CV............................ 5/12

CR-S006/024VDC1SS.................. 5/8

CR-M024AC3.. ........................... 5/10

CR-M110DC4L. . ......................... 5/11

CR-P/M 42V............................... 5/12

CR-S006/024VDC1SZ.................. 5/8

CR-M024AC3L.. ......................... 5/11

CR-M110DC4LG........................ 5/11

CR-P/M 52B.............................. 5/12

CR-S012/024VADC1SS................ 5/8

CR-M024AC4.. ........................... 5/10

CR-M120AC2. . ........................... 5/10

CR-P/M 52C.............................. 5/12

CR-S012/024VADC1SZ................ 5/8

CR-M024AC4G.......................... 5/11

CR-M120AC2L. . ......................... 5/11

CR-P/M 52D.............................. 5/12

CR-S012VDC1R........................... 5/8

CR-M024AC4L.. ......................... 5/11

CR-M120AC3. . ........................... 5/10

CR-P/M 62................................. 5/12

CR-S012VDC1RG........................ 5/8

CR-M024AC4LG........................ 5/11

CR-M120AC3L. . ......................... 5/11

CR-P/M 62C.............................. 5/12

CR-S024VADC1CRGS.................. 5/8

CR-M024DC2............................ 5/10

CR-M120AC4. . ........................... 5/10

CR-P/M 62CV............................ 5/12

CR-S024VADC1CRGZ.................. 5/8

CR-M024DC2L.. ......................... 5/11

CR-M120AC4L. . ......................... 5/11

CR-P/M 62D.............................. 5/12

CR-S024VADC1CRS.................... 5/8

CR-M024DC3............................ 5/10

CR-M120AC4LG........................ 5/11

CR-P/M 62DV............................ 5/12

CR-S024VADC1CRZ..................... 5/8

CR-M024DC3L.. ......................... 5/11

CR-M125DC2............................ 5/10

CR-P/M 62E............................... 5/12

CR-S024VDC1R........................... 5/8

CR-M024DC4............................ 5/10

CR-M125DC2L. . ......................... 5/11

CR-P/M 62EV............................. 5/12

CR-S024VDC1RG........................ 5/8

CR-M024DC4G.......................... 5/11

CR-M125DC3............................ 5/10

CR-P/M 62V............................... 5/12

CR-S048/060VADC1SS................ 5/8

CR-M024DC4L.. ......................... 5/11

CR-M125DC3L. . ......................... 5/11

CR-P/M 72................................. 5/12

CR-S048/060VADC1SZ................ 5/8

CR-M024DC4LD........................ 5/11

CR-M125DC4............................ 5/10

CR-P/M 72A.............................. 5/12

CR-S048VDC1R........................... 5/8

CR-M024DC4LDG.. .................... 5/11

CR-M125DC4L. . ......................... 5/11

CR-P/M 82................................. 5/12

CR-S048VDC1RG........................ 5/8

CR-M024DC4LG........................ 5/11

CR-M125DC4LG........................ 5/11

CR-P/M 92................................. 5/12

CR-S060VDC1R........................... 5/8

CR-M048AC2.. ........................... 5/10

CR-M220DC2............................ 5/10

CR-P/M 92C.............................. 5/12

CR-S060VDC1RG........................ 5/8

CR-M048AC2L.. ......................... 5/11

CR-M220DC2L. . ......................... 5/11

CR-P/M 92CV............................ 5/12

CR-S110/125VADC1SS................ 5/8

CR-M048AC3.. ........................... 5/10

CR-M220DC3............................ 5/10

CR-P/M 92V............................... 5/12

CR-S110/125VADC1SZ................ 5/8

CR-M048AC3L.. ......................... 5/11

CR-M220DC3L. . ......................... 5/11

CR-P012DC1............................... 5/9

CR-S110VADC1CRGS.................. 5/8

CR-M048AC4.. ........................... 5/10

CR-M220DC4............................ 5/10

CR-P012DC2............................... 5/9

CR-S110VADC1CRGZ.................. 5/8

CR-M048AC4L.. ......................... 5/11

CR-M220DC4L. . ......................... 5/11

CR-P024AC1............................... 5/9

CR-S110VADC1CRS.................... 5/8

CR-M048AC4LG........................ 5/11

CR-M220DC4LG........................ 5/11

CR-P024AC2............................... 5/9

CR-S110VADC1CRZ..................... 5/8

CR-M048DC2............................ 5/10

CR-M230AC2. . ........................... 5/10

CR-P024AC2G............................. 5/9

CR-S220/240VADC1SS................ 5/8

CR-M048DC2L.. ......................... 5/11

CR-M230AC2L. . ......................... 5/11

CR-P024DC1............................... 5/9

CR-S220/240VADC1SZ................ 5/8

CR-M048DC3............................ 5/10

CR-M230AC3. . ........................... 5/10

CR-P024DC2............................... 5/9

CR-S230VADC1CRGS.................. 5/8

CR-M048DC3L.. ......................... 5/11

CR-M230AC3L. . ......................... 5/11

CR-P024DC2............................... 5/9

CR-S230VADC1CRGZ.................. 5/8

CR-M048DC4............................ 5/10

CR-M230AC4. . ........................... 5/10

CR-P048AC1............................... 5/9

CR-S230VADC1CRS.................... 5/8

CR-M048DC4L.. ......................... 5/11

CR-M230AC4G.......................... 5/11

CR-P048AC2............................... 5/9

CR-S230VADC1CRZ..................... 5/8

2/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Index
Alphanumerical
Type

Page

Type

Page

Type

Page

Type

Page

CR-SJB20-BLACK....................... 5/8

CR-U060AC3............................. 5/13

CT-ARE...................................... 1/20

CT-MVS.12S.............................. 1/37

CR-SJB20-BLUE.......................... 5/8

CR-U110AC2............................. 5/13

CT-ARE...................................... 1/20

CT-MVS.21P.............................. 1/37

CR-SJB20-RED.. .......................... 5/8

CR-U110AC2L........................... 5/13

CT-ARE...................................... 1/20

CT-MVS.21S.............................. 1/37

CR-SM. . ....................................... 5/8

CR-U110AC3............................. 5/13

CT-ARE...................................... 1/20

CT-MVS.22P.............................. 1/37

CR-SSEP..................................... 5/8

CR-U110AC3L........................... 5/13

CT-ARS.11P............................... 1/38

CT-MVS.22S.............................. 1/37

CR-U 21.................................... 5/14

CR-U110DC2............................. 5/13

CT-ARS.11S............................... 1/38

CT-MVS.23P.............................. 1/37

CR-U 41.................................... 5/14

CR-U110DC2L........................... 5/13

CT-ARS.21P............................... 1/38

CT-MVS.23S.............................. 1/37

CR-U 41B.................................. 5/14

CR-U110DC3............................. 5/13

CT-ARS.21S............................... 1/38

CT-MXS.22P.............................. 1/37

CR-U 41BV................................ 5/14

CR-U110DC3L........................... 5/13

CT-AWE..................................... 1/20

CT-SAD.22................................... 1/8

CR-U 41C.................................. 5/14

CR-U120AC2............................. 5/13

CT-AWE..................................... 1/20

CT-SDD.22................................... 1/8

CR-U 41CV................................ 5/14

CR-U120AC2L........................... 5/13

CT-AWE..................................... 1/20

CT-SDE...................................... 1/21

CR-U 41V.................................. 5/14

CR-U120AC3............................. 5/13

CT-AWE .................................... 1/21

CT-SDE...................................... 1/21

CR-U 51B.................................. 5/14

CR-U120AC3L........................... 5/13

CT-AWE .................................... 1/21

CT-SDE...................................... 1/21

CR-U 51C.................................. 5/14

CR-U125DC3............................. 5/13

CT-AWE .................................... 1/21

CT-SDS.22P............................... 1/38

CR-U 51D.................................. 5/14

CR-U220DC2............................. 5/13

CT-AWE .................................... 1/21

CT-SDS.22S............................... 1/38

CR-U 61.................................... 5/14

CR-U220DC2L........................... 5/13

CT-AWE .................................... 1/21

CT-SDS.23P............................... 1/38

CR-U 61C.................................. 5/14

CR-U220DC3............................. 5/13

CT-AWE .................................... 1/21

CT-SDS.23S............................... 1/38

CR-U 61CV................................ 5/14

CR-U220DC3L........................... 5/13

CT-AWE .................................... 1/21

CT-TGD.12................................... 1/8

CR-U 61D.................................. 5/14

CR-U230AC2............................. 5/13

CT-AWE .................................... 1/21

CT-TGD.22................................... 1/8

CR-U 61DV................................ 5/14

CR-U230AC2L........................... 5/13

CT-AWE .................................... 1/21

CT-VWD.12.................................. 1/8

CR-U 61E.................................. 5/14

CR-U230AC3............................. 5/13

CT-EBD.12................................... 1/8

CT-VWE..................................... 1/20

CR-U 61EV................................ 5/14

CR-U230AC3L........................... 5/13

CT-EBE...................................... 1/21

CT-VWE..................................... 1/20

CR-U 61V.................................. 5/14

CR-U2S..................................... 5/13

CT-EBE...................................... 1/21

CT-VWE..................................... 1/20

CR-U 71.................................... 5/14

CR-U2SM.................................. 5/13

CT-EKE...................................... 1/21

CT-VWE..................................... 1/20

CR-U 71A.................................. 5/14

CR-U3E..................................... 5/13

CT-EKE...................................... 1/21

CT-VWE..................................... 1/20

CR-U 81.................................... 5/14

CR-U3S..................................... 5/13

CT-EKE...................................... 1/21

CT-VWE..................................... 1/20

CR-U 91.................................... 5/14

CR-U3SM.................................. 5/13

CT-ERD.12................................... 1/8

CT-WBS.22P.............................. 1/37

CR-U 91C.................................. 5/14

CR-UH....................................... 5/13

CT-ERD.22................................... 1/8

CT-WBS.22S.............................. 1/37

CR-U 91CV................................ 5/14

CT- MXS.22S............................. 1/37

CT-ERE...................................... 1/20

CT-YDE...................................... 1/21

CR-U 91V.................................. 5/14

CT-AHD.12. . ................................. 1/8

CT-ERE...................................... 1/20

CT-YDE...................................... 1/21

CR-U T...................................... 5/14

CT-AHD.22. . ................................. 1/8

CT-ERE...................................... 1/20

CT-YDE...................................... 1/21

CR-U012DC2............................. 5/13

CT-AHE. . .................................... 1/20

CT-ERE...................................... 1/20

CT-YDE...................................... 1/21

CR-U012DC2L........................... 5/13

CT-AHE. . .................................... 1/20

CT-ERE...................................... 1/20

CT-YDE...................................... 1/21

CR-U012DC3............................. 5/13

CT-AHE. . .................................... 1/20

CT-ERE...................................... 1/20

CT-YDE...................................... 1/21

CR-U012DC3L........................... 5/13

CT-AHE. . .................................... 1/20

CT-ERE...................................... 1/20

E

CR-U024AC2............................. 5/13

CT-AHE. . .................................... 1/20

CT-ERE...................................... 1/20

EPD24-TB-101-0.5A.................. 3/75

CR-U024AC2L........................... 5/13

CT-AHE. . .................................... 1/20

CT-ERS.12P............................... 1/38

EPD24-TB-101-10A................... 3/75

CR-U024AC3............................. 5/13

CT-AHE. . .................................... 1/20

CT-ERS.12S............................... 1/38

EPD24-TB-101-12A................... 3/75

CR-U024AC3L........................... 5/13

CT-AHE. . .................................... 1/20

CT-ERS.21P............................... 1/38

EPD24-TB-101-1A..................... 3/75

CR-U024DC2............................. 5/13

CT-AHE. . .................................... 1/20

CT-ERS.21S............................... 1/38

EPD24-TB-101-2A..................... 3/75

CR-U024DC2L........................... 5/13

CT-AHS.22P. . ............................. 1/38

CT-ERS.22P............................... 1/38

EPD24-TB-101-3A..................... 3/75

CR-U024DC3............................. 5/13

CT-AHS.22S. . ............................. 1/38

CT-ERS.22S............................... 1/38

EPD24-TB-101-4A..................... 3/75

CR-U024DC3L........................... 5/13

CT-AKE...................................... 1/21

CT-MBS.22P.............................. 1/37

EPD24-TB-101-6A..................... 3/75

CR-U048AC2............................. 5/13

CT-AKE...................................... 1/21

CT-MBS.22S.............................. 1/37

EPD24-TB-101-8A..................... 3/75

CR-U048AC2L........................... 5/13

CT-AKE...................................... 1/21

CT-MFD.12................................... 1/8

EPD-BB500............................... 3/75

CR-U048AC3............................. 5/13

CT-APS.12P............................... 1/38

CT-MFD.21................................... 1/8

EPD-SB21.................................. 3/75

CR-U048AC3L........................... 5/13

CT-APS.12S............................... 1/38

CT-MFE...................................... 1/20

F

CR-U048DC2............................. 5/13

CT-APS.21P............................... 1/38

CT-MFS.21................................. 1/37

FC2........................................... 5/47

CR-U048DC2L........................... 5/13

CT-APS.21S............................... 1/38

CT-MFS.21P............................... 1/37

CR-U048DC3............................. 5/13

CT-APS.22P............................... 1/38

CT-MKE..................................... 1/21

CR-U048DC3L........................... 5/13

CT-APS.22S............................... 1/38

CT-MVS.12P.............................. 1/37

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/4

7

Index
Alphanumerical
Type

7

Page

Type

Page

Type

Page

I

OBOC 1000-48-60VAC/DC. . ....... 5/47

ILPH BdC /RS 422 - 485 (24 V DC

OBOC 1000-5-12VDC................ 5/47

RB122A-48-60VAC/DC............... 5/36

power supply).. ........................... 4/37

OBOC 1500-24VAC/DC.............. 5/47

RBR101AR-24VAC/DC............... 5/35

ILPH RS 232 (24 V DC power supply).

OBOC 5000-115VAC/DC............ 5/47

RBR111A-24VAC/DC.................. 5/35

4/37

OBOC 5000-230VAC/DC............ 5/47

RBR111AR-24VAC/DC............... 5/35

ILPH RS 232 / FO-S (24...42 V AC/

OBOC 5000-24VDC................... 5/47

RBR121-12VDC......................... 5/36

DC power supply)....................... 4/37

OBRIC 0100-115-230VAC/DC.... 5/47

RBR121-12VDC......................... 5/36

ILPH RS 232 / RS 232 (115-230 V AC

OBRIC 0100-24VDC................... 5/47

RBR121-24VDC......................... 5/36

power supply).. ........................... 4/37

OBRIC 0100-48-60VAC/DC........ 5/47

RBR121-5VDC........................... 5/36

ILPH RS 232 / RS 232 (24-48 V DC

OBRIC 0100-5-12VDC. . .............. 5/47

RBR121-5VDC........................... 5/35

power supply).. ........................... 4/37

OBROA 1000-115VAC/DC.......... 5/47

RBR121A-115VAC/DC................ 5/36

ILPH RS 232 / RS 422-485......... 4/37

OBROA 1000-230VAC/DC.......... 5/47

RBR121A-115VAC/DC................ 5/35

ILPH RS 232 / RS 422-485......... 4/37

OBROA 1000-24VDC................. 5/47

RBR121A-230VAC/DC................ 5/36

ILPH RS 232 / RS 422-485 (115-230

OBROA 1000-48-60VAC/DC....... 5/47

RBR121A-230VAC/DC................ 5/35

V AC power supply).................... 4/37

OBROA 2000-24VDC................. 5/47

RBR121A-24VAC/DC.................. 5/36

ILPH RS 232 / RS 422-485 (24-48 V

OBROC 1000-115VAC/DC. . ........ 5/47

RBR121A-24VAC/DC.................. 5/35

DC power supply)....................... 4/37

OBROC 1000-230VAC/DC. . ........ 5/47

RBR121A-48-60VUC.................. 5/36

ILPH RS 232-RS 485 / Ethernet.. 4/37

OBROC 1000-24VDC................. 5/47

RBR121A-48-60VUC.................. 5/35

ILPH RS 422 - 485 / RS 422 - 485

OBROC 1000-48-60VAC/DC....... 5/47

RBR121A-60-230VUC................ 5/36

(24 V DC power supply).............. 4/37

OBROC 1000-5-12VDC.............. 5/47

RBR121AR-115VAC/DC............. 5/36

ILPH RS 485 / FO-S (24...42 V AC/

OBROC 1500-24VAC/DC. . .......... 5/47

RBR121AR-230VAC/DC............. 5/36

DC power supply)....................... 4/37

OBROC 5000-115VAC/DC. . ........ 5/47

RBR121-AU-12VDC................... 5/35

K

OBROC 5000-230VAC/DC. . ........ 5/47

RBR121-AU-24VDC................... 5/35

KA1-8029.................................. 1/39

OBROC 5000-24VDC................. 5/47

RBR122A-115VAC/DC................ 5/36

KA1-8030.................................. 1/39

R

RBR122A-230VAC/DC................ 5/36

M

RB101AR-24VAC/DC.. ................ 5/35

RBR122A-24VAC/DC.................. 5/36

MA16-1060................................ 1/39

RB111A-115VAC/DC.................. 5/35

RBR122A-48-60VUC.................. 5/36

MAR.01..................................... 1/40

RB111A-230VAC/DC.................. 5/35

S

MAR.01..................................... 1/40

RB111A-24VAC/DC. . .................. 5/35

SC 612...................................... 5/36

MAR.01................................... 2/130

RB111AR-24VAC/DC.. ................ 5/35

SC 612...................................... 5/47

MAR.01..................................... 4/22

RB121-12VDC........................... 5/36

SK 615 562-87........................... 1/39

MAR.02..................................... 1/40

RB121-12VDC........................... 5/36

SK 615 562-88........................... 1/39

MAR.02................................... 2/130

RB121-24VDC........................... 5/36

MAR.12..................................... 1/40

RB121-5VDC............................. 5/36

MAR.12................................... 2/130

RB121-5VDC............................. 5/35

MT-150B.................................... 1/39

RB121A-115VAC/DC.................. 5/36

MT-250B.................................... 1/39

RB121A-115VAC/DC.................. 5/35

MT-350B.................................... 1/39

RB121A-230VAC/DC.................. 5/36

O

RB121A-230VAC/DC.................. 5/35

OBIC 0100-115-230VAC/DC.. ..... 5/47

RB121A-24VAC/DC. . .................. 5/36

OBIC 0100-24VDC..................... 5/47

RB121A-24VAC/DC. . .................. 5/35

OBIC 0100-48-60VAC/DC.......... 5/47

RB121A-48-60VAC/DC. . ............. 5/36

OBIC 0100-5-12VDC.................. 5/47

RB121A-48-60VAC/DC. . ............. 5/35

OBOA 1000-115VAC/DC............ 5/47

RB121A-60-230VUC.................. 5/36

OBOA 1000-230VAC/DC............ 5/47

RB121AR-115VAC/DC. . .............. 5/36

OBOA 1000-24VDC.. .................. 5/47

RB121AR-230VAC/DC. . .............. 5/36

OBOA 1000-48-60VAC/DC......... 5/47

RB121-AU-12VDC. . .................... 5/35

OBOA 2000-24VDC.. .................. 5/47

RB121-AU-24VDC. . .................... 5/35

OBOC 1000-115VAC/DC............ 5/47

RB122A-115VAC/DC.................. 5/36

OBOC 1000-230VAC/DC............ 5/47

RB122A-230VAC/DC.................. 5/36

RB122A-24VAC/DC.................... 5/36

OBOC 1000-24VDC................... 5/47
2/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Index
Numerical
Order code

Type

Page

Order code

Type

Page

Order code

Type

Page

1SAR

1SNA645046R0700. . . RB121AR-115VAC/DC................. 5/36

1SNA645558R1500. . . OBROC 5000-115VAC/DC........... 5/47

1SAR700100R0005. .. C512-24.................................... 2/104

1SNA645047R0000. . . OBIC 0100-5-12VDC................... 5/47

1SNA645559R1600. . . OBROC 5000-230VAC/DC........... 5/47

1SAR700100R0010. .. C512-W. .................................... 2/104

1SNA645049R1200. . . OBIC 0100-48-60VAC/DC............ 5/47

1SNA645561R0000. . . OBROA 1000-48-60VAC/DC........ 5/47

1SAR700110R0010. .. C513-W. .................................... 2/104

1SNA645050R1700. . . OBOC 1000-5-12VDC. . ................ 5/47

1SNA645562R0100. . . OBROA 1000-115VAC/DC........... 5/47

1SFA

1SNA645051R0400. . . OBOC 1000-24VDC..................... 5/47

1SNA645571R0000. . . RBR121-24VDC. . ......................... 5/36

1SFA611410R1506... MT-150B..................................... 1/39

1SNA645053R0600. . . OBOC 1000-48-60VAC/DC.......... 5/47

1SNA645572R0000. . . RBR121-AU-24VDC..................... 5/35

1SFA611410R2506... MT-250B..................................... 1/39

1SNA645054R0700. . . OBOC 1000-115VAC/DC.. ............ 5/47

1SNA645573R0000. . . RBR121-12VDC. . ......................... 5/36

1SFA611410R3506... MT-350B..................................... 1/39

1SNA645058R1300. . . OBOC 5000-115VAC/DC.. ............ 5/47

1SNA645575R0000. . . RBR121-AU-12VDC..................... 5/35

1SFA611940R1060... MA16-1060................................. 1/39

1SNA645059R1400. . . OBOC 5000-230VAC/DC.. ............ 5/47

1SNA684202R0100. . . ILPH RS 232 (24 V DC power supply)..

1SFA616920R8029... KA1-8029.................................... 1/39

1SNA645061R0600. . . OBOA 1000-48-60VAC/DC.. ......... 5/47

4/37

1SFA616920R8030... KA1-8030.................................... 1/39

1SNA645062R0700. . . OBOA 1000-115VAC/DC. . ............ 5/47

1SNA684212R2200. . . ILPH RS 422 - 485 / RS 422 - 485 (24

1SNA

1SNA645071R0000. . . RB121-24VDC............................. 5/36

V DC power supply)... 4/37

1SNA116900R2700. .. BADH V0..................................... 5/47

1SNA645072R0000. . . RB121-AU-24VDC....................... 5/35

1SNA684231R2500. . . ILPH RS 232 / RS 422-485.......... 4/37

1SNA206754R0000. .. BJ 612-20................................... 5/36

1SNA645073R0000. . . RB121-12VDC............................. 5/36

1SNA684232R2600. . . ILPH BdC /RS 422 - 485 (24 V DC

1SNA206754R0000. .. BJ 612-20................................... 5/47

1SNA645075R0000. . . RB121-AU-12VDC....................... 5/35

power supply). . .......... 4/37

1SNA290474R0200. .. SC 612. ....................................... 5/36

1SNA645501R0500. . . RBR121A-24VAC/DC................... 5/36

1SNA684233R2700. . . ILPH RS 232 / RS 422-485.......... 4/37

1SNA290474R0200. .. SC 612. ....................................... 5/47

1SNA645502R0600. . . RBR121A-48-60VUC................... 5/36

1SNA684234R0200. . . ILPH RS 232 / RS 232 (115-230 V AC

1SNA290488R0100. .. BJ 612-10................................... 5/36

1SNA645503R0700. . . RBR121A-115VAC/DC................. 5/36

power supply). . .......... 4/37

1SNA290488R0100. .. BJ 612-10................................... 5/47

1SNA645504R0000. . . RBR121A-230VAC/DC................. 5/36

1SNA684234R2000. . . ILPH RS 232 / RS 232 (24-48 V DC

1SNA399903R0200. .. BADL V0...................................... 5/47

1SNA645505R0100. . . RBR121A-24VAC/DC................... 5/35

power supply). . .......... 4/37

1SNA399967R0100. .. BAM2 V0..................................... 5/47

1SNA645506R0200. . . RBR121A-48-60VUC................... 5/35

1SNA684236R2200. . . ILPH RS 232 / FO-S (24...42 V AC/DC

1SNA645001R0300. .. RB121A-24VAC/DC..................... 5/36

1SNA645507R0300. . . RBR121A-115VAC/DC................. 5/35

power supply). . .......... 4/37

1SNA645002R0400. .. RB121A-48-60VAC/DC................ 5/36

1SNA645508R1400. . . RBR121A-230VAC/DC................. 5/35

1SNA684246R0400. . . ILPH RS 485 / FO-S (24...42 V AC/DC

1SNA645003R0500. .. RB121A-115VAC/DC................... 5/36

1SNA645511R2600. . . RBR121AR-230VAC/DC............... 5/36

power supply). . .......... 4/37

1SNA645004R0400. .. RB121A-230VAC/DC................... 5/36

1SNA645512R2700. . . RBR122A-24VAC/DC................... 5/36

1SNA684252R0200. . . ILPH RS 232-RS 485 / Ethernet.... 4/37

1SNA645005R0700. .. RB121A-24VAC/DC..................... 5/35

1SNA645513R2000. . . RBR122A-230VAC/DC................. 5/36

1SNA684333R2300. . . ILPH RS 232 / RS 422-485 (24-48 V

1SNA645006R0000. .. RB121A-48-60VAC/DC................ 5/35

1SNA645514R2100. . . RBR111A-24VAC/DC................... 5/35

DC power supply)...... 4/37

1SNA645007R0100. .. RB121A-115VAC/DC................... 5/35

1SNA645518R0500. . . RBR111AR-24VAC/DC. . ............... 5/35

1SNA684334R2400. . . ILPH RS 232 / RS 422-485 (115-230

1SNA645008R1200. .. RB121A-230VAC/DC................... 5/35

1SNA645519R0600. . . RBR101AR-24VAC/DC. . ............... 5/35

V AC power supply)... 4/37

1SNA645011R2400. .. RB121AR-230VAC/DC................. 5/36

1SNA645520R0300. . . RBR121A-60-230VUC.. ................ 5/36

1SNB041391R0610.. . CR-SM.......................................... 5/8

1SNA645012R2500. .. RB122A-24VAC/DC..................... 5/36

1SNA645521R2000. . . OBRIC 0100-24VDC.................... 5/47

1SVR

1SNA645013R2600. .. RB122A-230VAC/DC................... 5/36

1SNA645522R2100. . . OBRIC 0100-115-230VAC/DC...... 5/47

1SVR010200R1600... CC-E I/I-1...................................... 4/8

1SNA645014R2700. .. RB111A-24VAC/DC..................... 5/35

1SNA645524R2300. . . OBROC 5000-24VDC. . ................. 5/47

1SVR010201R0300... CC-E I/I-2...................................... 4/8

1SNA645016R2100. .. RB111A-115VAC/DC................... 5/35

1SNA645525R2400. . . OBROC 1500-24VAC/DC............. 5/47

1SVR010203R0500... CC-E IAC/ILPO............................ 4/11

1SNA645017R2200. .. RB111A-230VAC/DC................... 5/35

1SNA645526R2500. . . OBROC 1000-230VAC/DC........... 5/47

1SVR011700R0000... CC-E/STD..................................... 4/8

1SNA645018R0300. .. RB111AR-24VAC/DC................... 5/35

1SNA645527R2600. . . OBROA 1000-24VDC................... 5/47

1SVR011701R2500... CC-E/RTD..................................... 4/9

1SNA645019R0400. .. RB101AR-24VAC/DC................... 5/35

1SNA645528R0700. . . OBROA 1000-230VAC/DC........... 5/47

1SVR011702R2600... CC-E/TC..................................... 4/10

1SNA645020R0100. .. RB121A-60-230VUC. . .................. 5/36

1SNA645529R0000. . . OBROA 2000-24VDC................... 5/47

1SVR011703R2700... CC-E/I......................................... 4/11

1SNA645021R2600. .. OBIC 0100-24VDC. . ..................... 5/47

1SNA645531R2200. . . FC2............................................. 5/47

1SVR011705R2100... CC-E/STD..................................... 4/8

1SNA645022R2700. .. OBIC 0100-115-230VAC/DC........ 5/47

1SNA645534R2500. . . RBR121-5VDC. . ........................... 5/36

1SVR011706R2200... CC-E/RTD..................................... 4/9

1SNA645024R2100. .. OBOC 5000-24VDC..................... 5/47

1SNA645535R2600. . . RBR121-12VDC. . ......................... 5/36

1SVR011707R2300... CC-E/TC..................................... 4/10

1SNA645025R2200. .. OBOC 1500-24VAC/DC............... 5/47

1SNA645536R2700. . . RBR121-5VDC. . ........................... 5/35

1SVR011708R0400... CC-E/I......................................... 4/11

1SNA645026R2300. .. OBOC 1000-230VAC/DC.. ............ 5/47

1SNA645540R1700. . . RBR122A-48-60VUC................... 5/36

1SVR011710R2100... CC-E V/V. . ..................................... 4/8

1SNA645027R2400. .. OBOA 1000-24VDC..................... 5/47

1SNA645541R0400. . . RBR122A-115VAC/DC................. 5/36

1SVR011711R1600... CC-E V/I........................................ 4/8

1SNA645028R0500. .. OBOA 1000-230VAC/DC. . ............ 5/47

1SNA645546R0100. . . RBR121AR-115VAC/DC............... 5/36

1SVR011712R1700... CC-E V/I........................................ 4/8

1SNA645029R0600. .. OBOA 2000-24VDC..................... 5/47

1SNA645547R0200. . . OBRIC 0100-5-12VDC................. 5/47

1SVR011713R1000... CC-E I/V........................................ 4/8

1SNA645034R2300. .. RB121-5VDC............................... 5/36

1SNA645549R1400. . . OBRIC 0100-48-60VAC/DC. . ........ 5/47

1SVR011714R1100... CC-E I/I......................................... 4/8

1SNA645035R2400. .. RB121-12VDC............................. 5/36

1SNA645550R1100. . . OBROC 1000-5-12VDC............... 5/47

1SVR011715R1200... CC-E I/I......................................... 4/8

1SNA645036R2500. .. RB121-5VDC............................... 5/35

1SNA645551R0600. . . OBROC 1000-24VDC. . ................. 5/47

1SVR011716R1300... CC-E I/V........................................ 4/8

1SNA645040R1500. .. RB122A-48-60VAC/DC................ 5/36

1SNA645553R0000. . . OBROC 1000-48-60VAC/DC........ 5/47

1SVR011717R1400... CC-E I/I......................................... 4/8

1SNA645041R0200. .. RB122A-115VAC/DC................... 5/36

1SNA645554R0100. . . OBROC 1000-115VAC/DC........... 5/47

1SVR011718R2500... CC-E I/I......................................... 4/8

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/6

7

Index
Numerical
Order code

7

Type

Page

Order code

Type

Page

Order code

Type

Page

1SVR011719R2600... CC-E V/V. ...................................... 4/8

1SVR011792R1000... CC-E RTD/I................................... 4/9

1SVR405541R3210... CR-S024VADC1CRZ...................... 5/8

1SVR011720R2300... CC-E V/V. ...................................... 4/8

1SVR011793R1100... CC-E RTD/I................................... 4/9

1SVR405541R3220... CR-S024VADC1CRGZ.................... 5/8

1SVR011721R1000... CC-E V/I........................................ 4/8

1SVR011794R1200... CC-E RTD/V.................................. 4/9

1SVR405541R6110... CR-S110VADC1CRS...................... 5/8

1SVR011722R1100... CC-E V/I........................................ 4/8

1SVR011795R1300... CC-E RTD/I................................... 4/9

1SVR405541R6120... CR-S110VADC1CRGS................... 5/8

1SVR011723R1200... CC-E V/V. ...................................... 4/8

1SVR011796R1400... CC-E RTD/I................................... 4/9

1SVR405541R6210... CR-S110VADC1CRZ...................... 5/8

1SVR011724R1300... CC-E I/I......................................... 4/8

1SVR011797R1500... CC-E RTD/V.................................. 4/9

1SVR405541R6220... CR-S110VADC1CRGZ.................... 5/8

1SVR011725R1400... CC-E I/I......................................... 4/8

1SVR011798R2600... CC-E RTD/I................................... 4/9

1SVR405541R7110... CR-S230VADC1CRS...................... 5/8

1SVR011726R1500... CC-E V/V. ...................................... 4/8

1SVR011799R2700... CC-E RTD/I................................... 4/9

1SVR405541R7120... CR-S230VADC1CRGS................... 5/8

1SVR011727R1600... CC-E I/I......................................... 4/8

1SVR040000R1700... CC-U/STD................................... 4/21

1SVR405541R7210... CR-S230VADC1CRZ...................... 5/8

1SVR011728R2700... CC-E I/I......................................... 4/8

1SVR040001R0400... CC-U/STD................................... 4/21

1SVR405541R7220... CR-S230VADC1CRGZ.................... 5/8

1SVR011729R2000... CC-E V/V. ...................................... 4/8

1SVR040002R0500... CC-U/RTD................................... 4/21

1SVR405598R0700... CR-SJB20-BLUE........................... 5/8

1SVR011730R2500... CC-E RTD/V.................................. 4/9

1SVR040003R0600... CC-U/RTD................................... 4/21

1SVR405598R0800... CR-SJB20-RED............................. 5/8

1SVR011731R1200... CC-E RTD/I................................... 4/9

1SVR040004R0700... CC-U/TC..................................... 4/21

1SVR405598R0900... CR-SJB20-BLACK......................... 5/8

1SVR011732R1300... CC-E RTD/I................................... 4/9

1SVR040005R0000... CC-U/TC..................................... 4/21

1SVR405599R0000... CR-SSEP. . ..................................... 5/8

1SVR011733R1400... CC-E RTD/V.................................. 4/9

1SVR040006R0100... CC-U/I. . ....................................... 4/21

1SVR405600R0000... CR-P024AC1. . ............................... 5/9

1SVR011734R1500... CC-E RTD/I................................... 4/9

1SVR040007R0200... CC-U/I. . ....................................... 4/21

1SVR405600R1000... CR-P024DC1. . ............................... 5/9

1SVR011735R1600... CC-E RTD/I................................... 4/9

1SVR040008R1300... CC-U/V....................................... 4/21

1SVR405600R2000... CR-P120AC1. . ............................... 5/9

1SVR011736R1700... CC-E RTD/V.................................. 4/9

1SVR040009R1400... CC-U/V....................................... 4/21

1SVR405600R3000... CR-P230AC1. . ............................... 5/9

1SVR011737R1000... CC-E RTD/I................................... 4/9

1SVR040010R0000... CC-U/STDR................................. 4/21

1SVR405600R4000... CR-P012DC1. . ............................... 5/9

1SVR011738R2100... CC-E RTD/I................................... 4/9

1SVR040011R2500... CC-U/STDR................................. 4/21

1SVR405600R5000... CR-P048AC1. . ............................... 5/9

1SVR011739R2200... CC-E RTD/V.................................. 4/9

1SVR040012R2600... CC-U/RTDR. . ............................... 4/21

1SVR405600R6000... CR-P048DC1. . ............................... 5/9

1SVR011740R0700... CC-E RTD/I................................... 4/9

1SVR040013R2700... CC-U/RTDR. . ............................... 4/21

1SVR405600R7000... CR-P110AC1. . ............................... 5/9

1SVR011741R2400... CC-E RTD/I................................... 4/9

1SVR040014R2000... CC-U/TCR................................... 4/21

1SVR405600R8000... CR-P110DC1. . ............................... 5/9

1SVR011750R0100... CC-E TC/V.................................. 4/10

1SVR040015R2100... CC-U/TCR................................... 4/21

1SVR405601R0000... CR-P024AC2. . ............................... 5/9

1SVR011751R2600... CC-E TC/I. ................................... 4/10

1SVR366017R0100... MAR.01....................................... 1/40

1SVR405601R1000... CR-P024DC2. . ............................... 5/9

1SVR011752R2700... CC-E TC/I. ................................... 4/10

1SVR366017R0100... MAR.01....................................... 1/40

1SVR405601R2000... CR-P120AC2. . ............................... 5/9

1SVR011753R2000... CC-E TC/V.................................. 4/10

1SVR366017R0100... MAR.01..................................... 2/130

1SVR405601R3000... CR-P230AC2. . ............................... 5/9

1SVR011754R2100... CC-E TC/I. ................................... 4/10

1SVR366017R0100... MAR.01....................................... 4/22

1SVR405601R4000... CR-P012DC2. . ............................... 5/9

1SVR011755R2200... CC-E TC/I. ................................... 4/10

1SVR402902R0000... CM-HE...................................... 2/116

1SVR405601R5000... CR-P048AC2. . ............................... 5/9

1SVR011760R0300... CC-E TC/V.................................. 4/10

1SVR405501R1010... CR-S005VDC1R............................ 5/8

1SVR405601R6000... CR-P048DC2. . ............................... 5/9

1SVR011761R2000... CC-E TC/I. ................................... 4/10

1SVR405501R1020... CR-S005VDC1RG.......................... 5/8

1SVR405601R7000... CR-P110AC2. . ............................... 5/9

1SVR011762R2100... CC-E TC/I. ................................... 4/10

1SVR405501R2010... CR-S012VDC1R............................ 5/8

1SVR405601R8000... CR-P110DC2. . ............................... 5/9

1SVR011763R2200... CC-E TC/V.................................. 4/10

1SVR405501R2020... CR-S012VDC1RG.......................... 5/8

1SVR405606R0000... CR-P024AC2G.............................. 5/9

1SVR011764R2300... CC-E TC/I. ................................... 4/10

1SVR405501R3010... CR-S024VDC1R............................ 5/8

1SVR405606R1000... CR-P024DC2. . ............................... 5/9

1SVR011765R2400... CC-E TC/I. ................................... 4/10

1SVR405501R3020... CR-S024VDC1RG.......................... 5/8

1SVR405606R3000... CR-P230AC2G.............................. 5/9

1SVR011770R0500... CC-E IAC/V................................. 4/11

1SVR405501R4010... CR-S048VDC1R............................ 5/8

1SVR405606R7000... CR-P110AC2G.............................. 5/9

1SVR011771R2200... CC-E IAC/I. .................................. 4/11

1SVR405501R4020... CR-S048VDC1RG.......................... 5/8

1SVR405611R0000... CR-M024AC2.............................. 5/10

1SVR011772R2300... CC-E IAC/I. .................................. 4/11

1SVR405501R5010... CR-S060VDC1R............................ 5/8

1SVR405611R0100... CR-M024AC2L............................ 5/11

1SVR011773R2400... CC-E IDC/V................................. 4/11

1SVR405501R5020... CR-S060VDC1RG.......................... 5/8

1SVR405611R1000... CR-M024DC2.............................. 5/10

1SVR011774R2500... CC-E IDC/I.................................. 4/11

1SVR405521R1100... CR-S006/024VDC1SS................... 5/8

1SVR405611R1100... CR-M024DC2L............................ 5/11

1SVR011775R2600... CC-E IDC/I.................................. 4/11

1SVR405521R1200... CR-S006/024VDC1SZ. . .................. 5/8

1SVR405611R2000... CR-M120AC2.............................. 5/10

1SVR011780R1100... CC-E IAC/V................................. 4/11

1SVR405521R3100... CR-S012/024VADC1SS................. 5/8

1SVR405611R2100... CR-M120AC2L............................ 5/11

1SVR011781R0600... CC-E IAC/I. .................................. 4/11

1SVR405521R3200... CR-S012/024VADC1SZ. . ................ 5/8

1SVR405611R3000... CR-M230AC2.............................. 5/10

1SVR011782R0700... CC-E IAC/I. .................................. 4/11

1SVR405521R5100... CR-S048/060VADC1SS................. 5/8

1SVR405611R3100... CR-M230AC2L............................ 5/11

1SVR011783R0000... CC-E IDC/V................................. 4/11

1SVR405521R5200... CR-S048/060VADC1SZ. . ................ 5/8

1SVR405611R4000... CR-M012DC2.............................. 5/10

1SVR011784R0100... CC-E IDC/I.................................. 4/11

1SVR405521R6100... CR-S110/125VADC1SS................. 5/8

1SVR405611R4100... CR-M012DC2L............................ 5/11

1SVR011785R1100... CC-E IDC/I.................................. 4/11

1SVR405521R6200... CR-S110/125VADC1SZ. . ................ 5/8

1SVR405611R4200... CR-M060DC2.............................. 5/10

1SVR011788R2400... CC-E RTD/V.................................. 4/9

1SVR405521R7100... CR-S220/240VADC1SS................. 5/8

1SVR405611R4300... CR-M060DC2L............................ 5/11

1SVR011789R2500... CC-E RTD/I................................... 4/9

1SVR405521R7200... CR-S220/240VADC1SZ. . ................ 5/8

1SVR405611R5000... CR-M048AC2.............................. 5/10

1SVR011790R2200... CC-E RTD/I................................... 4/9

1SVR405541R3110... CR-S024VADC1CRS...................... 5/8

1SVR405611R5100... CR-M048AC2L............................ 5/11

1SVR011791R1700... CC-E RTD/V.................................. 4/9

1SVR405541R3120... CR-S024VADC1CRGS................... 5/8

1SVR405611R6000... CR-M048DC2.............................. 5/10

2/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Index
Numerical
Order code

Type

Page

Order code

Type

Page

Order code

Type

Page

1SVR405611R6100... CR-M048DC2L............................ 5/11

1SVR405613R7100... CR-M110AC4L............................ 5/11

1SVR405611R7000... CR-M110AC2.............................. 5/10

1SVR405613R8000... CR-M110DC4.............................. 5/10

1SVR405622R2100... CR-U120AC3L. . ........................... 5/13
1SVR405622R3000... CR-U230AC3. . ............................. 5/13

1SVR405611R7100... CR-M110AC2L............................ 5/11

1SVR405613R8100... CR-M110DC4L............................ 5/11

1SVR405622R3100... CR-U230AC3L. . ........................... 5/13

1SVR405611R8000... CR-M110DC2.............................. 5/10

1SVR405613R8200... CR-M125DC4.............................. 5/10

1SVR405622R4000... CR-U012DC3.............................. 5/13

1SVR405611R8100... CR-M110DC2L............................ 5/11

1SVR405613R8300... CR-M125DC4L............................ 5/11

1SVR405622R4100... CR-U012DC3L. . ........................... 5/13

1SVR405611R8200... CR-M125DC2.............................. 5/10

1SVR405613R9000... CR-M220DC4.............................. 5/10

1SVR405622R5000... CR-U048AC3. . ............................. 5/13

1SVR405611R8300... CR-M125DC2L............................ 5/11

1SVR405613R9100... CR-M220DC4L............................ 5/11

1SVR405622R5100... CR-U048AC3L. . ........................... 5/13

1SVR405611R9000... CR-M220DC2.............................. 5/10

1SVR405614R1100... CR-M024DC4LD. . ........................ 5/11

1SVR405622R5200... CR-U060AC3. . ............................. 5/13

1SVR405611R9100... CR-M220DC2L............................ 5/11

1SVR405618R0000... CR-M024AC4G. . .......................... 5/11

1SVR405622R6000... CR-U048DC3.............................. 5/13

1SVR405612R0000... CR-M024AC3.............................. 5/10

1SVR405618R0100... CR-M024AC4LG. . ........................ 5/11

1SVR405622R6100... CR-U048DC3L. . ........................... 5/13

1SVR405612R0100... CR-M024AC3L............................ 5/11

1SVR405618R1000... CR-M024DC4G........................... 5/11

1SVR405622R7000... CR-U110AC3. . ............................. 5/13

1SVR405612R1000... CR-M024DC3.............................. 5/10

1SVR405618R1100... CR-M024DC4LG. . ........................ 5/11

1SVR405622R7100... CR-U110AC3L. . ........................... 5/13

1SVR405612R1100... CR-M024DC3L............................ 5/11

1SVR405618R1400... CR-M024DC4LDG....................... 5/11

1SVR405622R8000... CR-U110DC3.............................. 5/13

1SVR405612R2000... CR-M120AC3.............................. 5/10

1SVR405618R2100... CR-M120AC4LG. . ........................ 5/11

1SVR405622R8100... CR-U110DC3L. . ........................... 5/13

1SVR405612R2100... CR-M120AC3L............................ 5/11

1SVR405618R3000... CR-M230AC4G. . .......................... 5/11

1SVR405622R8200... CR-U125DC3.............................. 5/13

1SVR405612R3000... CR-M230AC3.............................. 5/10

1SVR405618R3100... CR-M230AC4LG. . ........................ 5/11

1SVR405622R9000... CR-U220DC3.............................. 5/13

1SVR405612R3100... CR-M230AC3L............................ 5/11

1SVR405618R4100... CR-M012DC4LG. . ........................ 5/11

1SVR405622R9100... CR-U220DC3L. . ........................... 5/13

1SVR405612R4000... CR-M012DC3.............................. 5/10

1SVR405618R4300... CR-M060DC4LG. . ........................ 5/11

1SVR405650R0000... CR-PLS......................................... 5/9

1SVR405612R4100... CR-M012DC3L............................ 5/11

1SVR405618R4400... CR-M012DC4LDG....................... 5/11

1SVR405650R0100... CR-PLSx....................................... 5/9

1SVR405612R4200... CR-M060DC3.............................. 5/10

1SVR405618R5100... CR-M048AC4LG. . ........................ 5/11

1SVR405650R0200... CR-PLC. . ....................................... 5/9

1SVR405612R4300... CR-M060DC3L............................ 5/11

1SVR405618R6100... CR-M048DC4LG. . ........................ 5/11

1SVR405650R1000... CR-PSS. . ....................................... 5/9

1SVR405612R5000... CR-M048AC3.............................. 5/10

1SVR405618R7000... CR-M110AC4G. . .......................... 5/11

1SVR405651R0000... CR-P/M 22.................................. 5/12

1SVR405612R5100... CR-M048AC3L............................ 5/11

1SVR405618R7100... CR-M110AC4LG. . ........................ 5/11

1SVR405651R1000... CR-M2SS.................................... 5/11

1SVR405612R5200... CR-M060AC3.............................. 5/10

1SVR405618R8100... CR-M110DC4LG. . ........................ 5/11

1SVR405651R1100... CR-M2LS.................................... 5/11

1SVR405612R6000... CR-M048DC3.............................. 5/10

1SVR405618R8300... CR-M125DC4LG. . ........................ 5/11

1SVR405651R1200... CR-M2LC.................................... 5/11

1SVR405612R6100... CR-M048DC3L............................ 5/11

1SVR405618R9100... CR-M220DC4LG. . ........................ 5/11

1SVR405651R1300... CR-M2SF.................................... 5/11

1SVR405612R7000... CR-M110AC3.............................. 5/10

1SVR405621R0000... CR-U024AC2. . ............................. 5/13

1SVR405651R2000... CR-M3SS.................................... 5/11

1SVR405612R7100... CR-M110AC3L............................ 5/11

1SVR405621R0100... CR-U024AC2L. . ........................... 5/13

1SVR405651R2100... CR-M3LS.................................... 5/11

1SVR405612R8000... CR-M110DC3.............................. 5/10

1SVR405621R1000... CR-U024DC2.............................. 5/13

1SVR405651R3000... CR-M4SS.................................... 5/11

1SVR405612R8100... CR-M110DC3L............................ 5/11

1SVR405621R1100... CR-U024DC2L. . ........................... 5/13

1SVR405651R3100... CR-M4LS.................................... 5/11

1SVR405612R8200... CR-M125DC3.............................. 5/10

1SVR405621R2000... CR-U120AC2. . ............................. 5/13

1SVR405651R3200... CR-M4LC.................................... 5/11

1SVR405612R8300... CR-M125DC3L............................ 5/11

1SVR405621R2100... CR-U120AC2L. . ........................... 5/13

1SVR405651R3300... CR-M4SF.................................... 5/11

1SVR405612R9000... CR-M220DC3.............................. 5/10

1SVR405621R3000... CR-U230AC2. . ............................. 5/13

1SVR405652R0000... CR-P/M 42.................................. 5/12

1SVR405612R9100... CR-M220DC3L............................ 5/11

1SVR405621R3100... CR-U230AC2L. . ........................... 5/13

1SVR405652R1000... CR-P/M 42V................................ 5/12

1SVR405613R0000... CR-M024AC4.............................. 5/10

1SVR405621R4000 .CR-U012DC2.............................. 5/13

1SVR405652R4000... CR-P/M 42B................................ 5/12

1SVR405613R0100... CR-M024AC4L............................ 5/11

1SVR405621R4100... CR-U012DC2L. . ........................... 5/13

1SVR405652R4100... CR-P/M 42BV.............................. 5/12

1SVR405613R1000... CR-M024DC4.............................. 5/10

1SVR405621R5000... CR-U048AC2. . ............................. 5/13

1SVR405652R9000... CR-P/M 42C. . .............................. 5/12

1SVR405613R1100... CR-M024DC4L............................ 5/11

1SVR405621R5100... CR-U048AC2L. . ........................... 5/13

1SVR405652R9100... CR-P/M 42CV. . ............................ 5/12

1SVR405613R2000... CR-M120AC4.............................. 5/10

1SVR405621R6000... CR-U048DC2.............................. 5/13

1SVR405653R0000... CR-P/M 52B................................ 5/12

1SVR405613R2100... CR-M120AC4L............................ 5/11

1SVR405621R6100... CR-U048DC2L. . ........................... 5/13

1SVR405653R1000... CR-P/M 52C. . .............................. 5/12

1SVR405613R3000... CR-M230AC4.............................. 5/10

1SVR405621R7000... CR-U110AC2. . ............................. 5/13

1SVR405653R4000... CR-P/M 52D................................ 5/12

1SVR405613R3100... CR-M230AC4L............................ 5/11

1SVR405621R7100... CR-U110AC2L. . ........................... 5/13

1SVR405654R0000... CR-P/M 62.................................. 5/12

1SVR405613R4000... CR-M012DC4.............................. 5/10

1SVR405621R8000... CR-U110DC2.............................. 5/13

1SVR405654R0100... CR-P/M 92.................................. 5/12

1SVR405613R4100... CR-M012DC4L............................ 5/11

1SVR405621R8100... CR-U110DC2L. . ........................... 5/13

1SVR405654R1000... CR-P/M 62V................................ 5/12

1SVR405613R4200... CR-M060DC4.............................. 5/10

1SVR405621R9000... CR-U220DC2.............................. 5/13

1SVR405654R1100... CR-P/M 92V................................ 5/12

1SVR405613R4300... CR-M060DC4L............................ 5/11

1SVR405621R9100... CR-U220DC2L. . ........................... 5/13

1SVR405654R4000... CR-P/M 62E................................ 5/12

1SVR405613R5000... CR-M048AC4.............................. 5/10

1SVR405622R0000... CR-U024AC3. . ............................. 5/13

1SVR405654R4100... CR-P/M 62EV.............................. 5/12

1SVR405613R5100... CR-M048AC4L............................ 5/11

1SVR405622R0100... CR-U024AC3L. . ........................... 5/13

1SVR405655R0000... CR-P/M 62C. . .............................. 5/12

1SVR405613R6000... CR-M048DC4.............................. 5/10

1SVR405622R1000... CR-U024DC3.............................. 5/13

1SVR405655R0100... CR-P/M 92C. . .............................. 5/12

1SVR405613R6100... CR-M048DC4L............................ 5/11

1SVR405622R1100... CR-U024DC3L. . ........................... 5/13

1SVR405655R1000... CR-P/M 62CV. . ............................ 5/12

1SVR405613R7000... CR-M110AC4.............................. 5/10

1SVR405622R2000... CR-U120AC3. . ............................. 5/13

1SVR405655R1100... CR-P/M 92CV. . ............................ 5/12

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/8

7

Index
Numerical
Order code

7

Type

Page

Order code

Type

Page

Order code

Type

Page

1SVR405655R4000... CR-P/M 62D................................ 5/12

1SVR427030R0000... CP-E 24/0.75.............................. 3/20

1SVR430851R1100... CM-ENS.................................... 2/115

1SVR405655R4100... CR-P/M 62DV. . ............................ 5/12

1SVR427030R2000... CP-E 48/0.62.............................. 3/20

1SVR430851R1200... CM-ENS UP/DOWN................... 2/115

1SVR405656R0000... CR-P/M 72.................................. 5/12

1SVR427031R0000... CP-E 24/1.25.............................. 3/20

1SVR430851R1300... CM-ENS.................................... 2/115

1SVR405656R1000... CR-P/M 72A................................ 5/12

1SVR427031R2000... CP-E 48/1.25.............................. 3/20

1SVR430851R9100... CM-ENS.................................... 2/115

1SVR405656R2000... CR-P/M 82.................................. 5/12

1SVR427032R0000... CP-E 24/2.5................................ 3/20

1SVR430851R9200... CM-ENS UP/DOWN................... 2/115

1SVR405658R0000... CR-PM.......................................... 5/9

1SVR427032R1000... CP-E 12/2.5................................ 3/20

1SVR440005R0100... COV.02. . .................................... 2/130

1SVR405658R1000... CR-MM....................................... 5/11

1SVR427033R3000... CP-E 5/3.0.................................. 3/20

1SVR440029R0100... ADP.02...................................... 2/130

1SVR405658R5000... CR-PJ........................................... 5/9

1SVR427034R0000... CP-E 24/5.0................................ 3/20

1SVR440709R0000... CL-LEC.CI000............................... 6/7

1SVR405658R6000... CR-MJ......................................... 5/11

1SVR427034R2000... CP-E 48/5.0................................ 3/20

1SVR440709R5000... CL-LER.2O.................................... 6/7

1SVR405659R0000... CR-PH........................................... 5/9

1SVR427035R0000... CP-E 24/10.0.............................. 3/20

1SVR440710R0200... CL-LSR.CX12DC1.. ........................ 6/6

1SVR405659R1000... CR-MH........................................ 5/11

1SVR427035R1000... CP-E 12/10.0.............................. 3/20

1SVR440710R0300... CL-LSR.C12DC1........................... 6/6

1SVR405659R1100... CR-MH1...................................... 5/11

1SVR427035R2000... CP-E 48/10.0.............................. 3/20

1SVR440711R0100... CL-LSR.12DC2.............................. 6/6

1SVR405660R0000... CR-U3S. ...................................... 5/13

1SVR427036R0000... CP-E 24/20.0.............................. 3/20

1SVR440711R0200... CL-LSR.CX12DC2.. ........................ 6/6

1SVR405660R0100... CR-U3E....................................... 5/13

1SVR427041R0000... CP-D 24/0.42.............................. 3/10

1SVR440711R0300... CL-LSR.C12DC2........................... 6/6

1SVR405660R1100... CR-U3SM.................................... 5/13

1SVR427041R0000... CP-D 24/0.42................................ 6/8

1SVR440711R1200... CL-LST.CX12DC2.......................... 6/6

1SVR405661R0000... CR-U 21...................................... 5/14

1SVR427041R1000... CP-D 12/0.83.............................. 3/10

1SVR440711R1300... CL-LST.C12DC2............................ 6/6

1SVR405662R0000... CR-U 41...................................... 5/14

1SVR427043R0100... CP-D 24/1.3................................ 3/10

1SVR440712R0200... CL-LSR.CX12AC1. . ........................ 6/6

1SVR405662R1000... CR-U 41V.................................... 5/14

1SVR427043R0100... CP-D 24/1.3.................................. 6/8

1SVR440712R0300... CL-LSR.C12AC1. . .......................... 6/6

1SVR405662R4000... CR-U 41B. ................................... 5/14

1SVR427043R1200... CP-D 12/2.1................................ 3/10

1SVR440713R0100... CL-LSR.12AC2.............................. 6/6

1SVR405662R4100... CR-U 41BV. ................................. 5/14

1SVR427044R0200... CP-D 24/2.5................................ 3/10

1SVR440713R0200... CL-LSR.CX12AC2. . ........................ 6/6

1SVR405662R9000... CR-U 41C.................................... 5/14

1SVR427045R0400... CP-D 24/4.2................................ 3/10

1SVR440713R0300... CL-LSR.C12AC2. . .......................... 6/6

1SVR405662R9100... CR-U 41CV.................................. 5/14

1SVR427049R0000... CP-D RU..................................... 3/51

1SVR440720R0200... CL-LMR.CX18DC1......................... 6/7

1SVR405663R0000... CR-U 51B. ................................... 5/14

1SVR427054R0000... CP-T 24/5.0.. ............................... 3/34

1SVR440720R0300... CL-LMR.C18DC1. . ......................... 6/7

1SVR405663R1000... CR-U 51C.................................... 5/14

1SVR427054R2000... CP-T 48/5.0.. ............................... 3/34

1SVR440721R0000... CL-LER.18DC2.............................. 6/7

1SVR405663R4000... CR-U 51D. ................................... 5/14

1SVR427055R0000... CP-T 24/10.0. . ............................. 3/34

1SVR440721R0200... CL-LMR.CX18DC2......................... 6/7

1SVR405664R0000... CR-U 61...................................... 5/14

1SVR427055R2000... CP-T 48/10.0. . ............................. 3/34

1SVR440721R0300... CL-LMR.C18DC2. . ......................... 6/7

1SVR405664R0100... CR-U 91...................................... 5/14

1SVR427056R0000... CP-T 24/20.0. . ............................. 3/34

1SVR440721R1000... CL-LET.20DC2. . ............................. 6/7

1SVR405664R1000... CR-U 61V.................................... 5/14

1SVR427056R2000... CP-T 48/20.0. . ............................. 3/34

1SVR440721R1200... CL-LMT.CX20DC2.. ........................ 6/7

1SVR405664R1100... CR-U 91V.................................... 5/14

1SVR427057R0000... CP-T 24/40.0. . ............................. 3/34

1SVR440721R1300... CL-LMT.C20DC2.. .......................... 6/7

1SVR405664R4000... CR-U 61E.................................... 5/14

1SVR427060R0300... CP-B 24/3.0................................ 3/68

1SVR440722R0200... CL-LMR.CX18AC1......................... 6/7

1SVR405664R4100... CR-U 61EV.................................. 5/14

1SVR427060R1000... CP-B 24/10.0.............................. 3/68

1SVR440722R0300... CL-LMR.C18AC1........................... 6/7

1SVR405665R0000... CR-U 61C.................................... 5/14

1SVR427060R2000... CP-B 24/20.0.............................. 3/68

1SVR440723R0000... CL-LER.18AC2.............................. 6/7

1SVR405665R0100... CR-U 91C.................................... 5/14

1SVR427065R0000... CP-B EXT.2.. ................................ 3/68

1SVR440723R0200... CL-LMR.CX18AC2......................... 6/7

1SVR405665R1000... CR-U 61CV.................................. 5/14

1SVR427071R0000... CP-A RU..................................... 3/51

1SVR440723R0300... CL-LMR.C18AC2........................... 6/7

1SVR405665R1100... CR-U 91CV.................................. 5/14

1SVR427075R0000... CP-A CM..................................... 3/51

1SVR440799R5000... CL-LAS.FD001.. ............................. 6/8

1SVR405665R4000... CR-U 61D. ................................... 5/14

1SVR427081R0000... CP-C MM.................................... 3/45

1SVR440799R5100... CL-LAS.TK011.. ............................. 6/8

1SVR405665R4100... CR-U 61DV. ................................. 5/14

1SVR427090R0280... CP-ASI/2.8.................................. 3/60

1SVR440799R6000... CL-LAS.TK001.. ............................. 6/8

1SVR405666R0000... CR-U 71...................................... 5/14

1SVR427090R0400... CP-ASI/4.0.................................. 3/60

1SVR440799R6100... CL-LAS.TK002.. ............................. 6/8

1SVR405666R1000... CR-U 71A. ................................... 5/14

1SVR427090R0800... CP-ASI/8.0.................................. 3/60

1SVR440799R7000... CL-LAS.MD003.. ............................ 6/8

1SVR405666R2000... CR-U 81...................................... 5/14

1SVR427095R0400... CP-ASI/4.0 DC/DC.. ..................... 3/60

1SVR440799R8000... CL-LAS.PS002.............................. 6/8

1SVR405667R0000... CR-U T........................................ 5/14

1SVR430005R0100... COV.01. . ...................................... 1/40

1SVR440821R0000... CL-LDC.LDC2.. .............................. 6/9

1SVR405669R0000... CR-UH........................................ 5/13

1SVR430005R0100... COV.01. . .................................... 2/130

1SVR440821R1000... CL-LDC.LNDC2............................. 6/9

1SVR405670R0000... CR-U2S. ...................................... 5/13

1SVR430005R0100... COV.01. . ...................................... 4/22

1SVR440823R0000... CL-LDC.LAC2. . .............................. 6/9

1SVR405670R1100... CR-U2SM.................................... 5/13

1SVR430029R0100... ADP.01........................................ 1/40

1SVR440823R1000... CL-LDC.LNAC2............................. 6/9

1SVR423418R9000... CP-RUD...................................... 3/51

1SVR430029R0100... ADP.01........................................ 1/40

1SVR440839R4400... CL-LDD.K...................................... 6/6

1SVR427014R0000... CP-S 24/5.0................................ 3/45

1SVR430029R0100... ADP.01...................................... 2/130

1SVR440839R4400... CL-LDD.K...................................... 6/9

1SVR427015R0100... CP-S 24/10.0.............................. 3/45

1SVR430029R0100... ADP.01........................................ 4/22

1SVR440839R4500... CL-LDD.XK.................................... 6/6

1SVR427016R0100... CP-S 24/20.0.............................. 3/45

1SVR430043R0000... MAR.02....................................... 1/40

1SVR440839R4500... CL-LDD.XK.................................... 6/9

1SVR427024R0000... CP-C 24/5.0................................ 3/45

1SVR430043R0000... MAR.02..................................... 2/130

1SVR440841R0000... CL-LDC.SDC2............................... 6/6

1SVR427025R0000... CP-C 24/10.0.............................. 3/45

1SVR430851R0100... CM-ENS.................................... 2/115

1SVR440843R0000... CL-LDC.SAC2............................... 6/6

1SVR427026R0000... CP-C 24/20.0.............................. 3/45

1SVR430851R0200... CM-ENS UP/DOWN................... 2/115

1SVR440851R0000... CL-LDR.16DC2. . ............................ 6/9

2/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Index
Numerical
Order code

Type

Page

Order code

Type

Page

Order code

Type

Page

1SVR440851R1000... CL-LDT.16DC2.............................. 6/9

1SVR450332R0100... CM-LWN..................................... 2/76

1SVR550141R1100... CT-AWE . . .................................... 1/21

1SVR440851R2000... CL-LDR.17DC2. . ............................ 6/9

1SVR450334R0000... CM-LWN..................................... 2/76

1SVR550141R2100... CT-AWE . . .................................... 1/21

1SVR440851R3000... CL-LDT.17DC2.............................. 6/9

1SVR450334R0100... CM-LWN..................................... 2/76

1SVR550141R4100... CT-AWE . . .................................... 1/21

1SVR440853R0000... CL-LDR.16AC2.............................. 6/9

1SVR450335R0000... CM-LWN..................................... 2/76

1SVR550148R1100... CT-AWE . . .................................... 1/21

1SVR440899R1000... CL-LAD.FD001.............................. 6/9

1SVR450335R0100... CM-LWN..................................... 2/76

1SVR550148R2100... CT-AWE . . .................................... 1/21

1SVR440899R2000... CL-LAD.FD011.............................. 6/9

1SVR500020R0000... CT-MFD.12.................................... 1/8

1SVR550148R4100... CT-AWE . . .................................... 1/21

1SVR440899R3000... CL-LAD.FD002.............................. 6/9

1SVR500020R1100... CT-MFD.21.................................... 1/8

1SVR550150R3100... CT-AWE. . ..................................... 1/20

1SVR440899R6000... CL-LAD.TK001.............................. 6/9

1SVR500100R0000... CT-ERD.12.................................... 1/8

1SVR550151R3100... CT-AWE. . ..................................... 1/20

1SVR440899R6100... CL-LAD.TK002.............................. 6/9

1SVR500100R0100... CT-ERD.22.................................... 1/8

1SVR550158R3100... CT-AWE. . ..................................... 1/20

1SVR440899R6200... CL-LAD.TK003.............................. 6/9

1SVR500110R0000... CT-AHD.12.................................... 1/8

1SVR550160R1100... CT-EBE.. ...................................... 1/21

1SVR440899R6300... CL-LAD.TK004.............................. 6/9

1SVR500110R0100... CT-AHD.22.................................... 1/8

1SVR550167R1100... CT-EBE.. ...................................... 1/21

1SVR440899R6400... CL-LAD.TK005.............................. 6/9

1SVR500130R0000... CT-VWD.12. . .................................. 1/8

1SVR550200R1100... CT-YDE....................................... 1/21

1SVR440899R6500... CL-LAD.TK006.............................. 6/9

1SVR500150R0000... CT-EBD.12.................................... 1/8

1SVR550200R2100... CT-YDE....................................... 1/21

1SVR440899R6600... CL-LAD.TK007.............................. 6/8

1SVR500160R0000... CT-TGD.12.................................... 1/8

1SVR550200R4100... CT-YDE....................................... 1/21

1SVR440899R6700... CL-LAD.TK011.............................. 6/9

1SVR500160R0100... CT-TGD.22.................................... 1/8

1SVR550207R1100... CT-YDE....................................... 1/21

1SVR440899R6900... CL-LAD.TK009.............................. 6/9

1SVR500210R0100... CT-SAD.22.................................... 1/8

1SVR550207R2100... CT-YDE....................................... 1/21

1SVR440899R7000... CL-LAD.MD004............................. 6/9

1SVR500211R0100... CT-SDD.22.................................... 1/8

1SVR550207R4100... CT-YDE....................................... 1/21

1SVR450050R0000... CM-ENN. ................................... 2/115

1SVR510730R0300... CM-UFD.M22.............................. 2/54

1SVR550210R4100... CT-SDE....................................... 1/21

1SVR450051R0000... CM-ENN. ................................... 2/115

1SVR510730R0300... CM-UFD.M31.............................. 2/54

1SVR550212R4100... CT-SDE....................................... 1/21

1SVR450055R0000... CM-ENN. ................................... 2/115

1SVR550019R0000... CT-MKE....................................... 1/21

1SVR550217R4100... CT-SDE....................................... 1/21

1SVR450056R0000... CM-SE-300............................... 2/116

1SVR550029R8100... CT-MFE....................................... 1/20

1SVR550509R1000... CT-EKE. . ...................................... 1/21

1SVR450056R0100... CM-SE-600............................... 2/116

1SVR550100R1100... CT-ERE.. ...................................... 1/20

1SVR550509R2000... CT-EKE. . ...................................... 1/21

1SVR450056R0200... CM-SE-1000............................. 2/116

1SVR550100R2100... CT-ERE.. ...................................... 1/20

1SVR550509R4000... CT-EKE. . ...................................... 1/21

1SVR450056R6000... CM-KH-3. .................................. 2/116

1SVR550100R4100... CT-ERE.. ...................................... 1/20

1SVR550519R1000... CT-AKE.. ...................................... 1/21

1SVR450056R7000... CM-AH-3. . ................................. 2/116

1SVR550100R5100... CT-ERE.. ...................................... 1/20

1SVR550519R2000... CT-AKE.. ...................................... 1/21

1SVR450056R8000... CM-GM-1.................................. 2/116

1SVR550107R1100... CT-ERE.. ...................................... 1/20

1SVR550519R4000... CT-AKE.. ...................................... 1/21

1SVR450059R0000... CM-ENN. ................................... 2/115

1SVR550107R2100... CT-ERE.. ...................................... 1/20

1SVR550800R9300... CM-MSE.. .................................... 2/90

1SVR450116R1000... CM-CT 50/1.............................. 2/131

1SVR550107R4100... CT-ERE.. ...................................... 1/20

1SVR550801R9300... CM-MSE.. .................................... 2/90

1SVR450116R1100... CM-CT 75/1.............................. 2/131

1SVR550107R5100... CT-ERE.. ...................................... 1/20

1SVR550805R9300... CM-MSE.. .................................... 2/90

1SVR450116R1200... CM-CT 100/1............................ 2/131

1SVR550110R1100... CT-AHE....................................... 1/20

1SVR550824R9100... CM-PFE.. ..................................... 2/33

1SVR450116R1300... CM-CT 150/1............................ 2/131

1SVR550110R2100... CT-AHE....................................... 1/20

1SVR550850R9400... CM-ENE MAX............................ 2/115

1SVR450116R1400... CM-CT 200/1............................ 2/131

1SVR550110R4100... CT-AHE....................................... 1/20

1SVR550850R9500... CM-ENE MIN............................. 2/115

1SVR450116R5000... CM-CT 50/5.............................. 2/131

1SVR550111R1100... CT-AHE....................................... 1/20

1SVR550851R9400... CM-ENE MAX............................ 2/115

1SVR450116R5100... CM-CT 75/5.............................. 2/131

1SVR550111R2100... CT-AHE....................................... 1/20

1SVR550851R9500... CM-ENE MIN............................. 2/115

1SVR450116R5200... CM-CT 100/5............................ 2/131

1SVR550111R4100... CT-AHE....................................... 1/20

1SVR550855R9400... CM-ENE MAX............................ 2/115

1SVR450116R5300... CM-CT 150/5............................ 2/131

1SVR550118R1100... CT-AHE....................................... 1/20

1SVR550855R9500... CM-ENE MIN............................. 2/115

1SVR450116R5400... CM-CT 200/5............................ 2/131

1SVR550118R2100... CT-AHE....................................... 1/20

1SVR550870R9400... CM-PVE...................................... 2/33

1SVR450117R1100... CM-CT 300/1............................ 2/131

1SVR550118R4100... CT-AHE....................................... 1/20

1SVR550871R9500... CM-PVE...................................... 2/33

1SVR450117R1200... CM-CT 400/1............................ 2/131

1SVR550120R1100... CT-ARE....................................... 1/20

1SVR550881R9400... CM-PBE...................................... 2/33

1SVR450117R1300... CM-CT 500/1............................ 2/131

1SVR550120R4100... CT-ARE....................................... 1/20

1SVR550882R9500... CM-PBE...................................... 2/33

1SVR450117R1400... CM-CT 600/1............................ 2/131

1SVR550127R1100... CT-ARE....................................... 1/20

1SVR560730R3400... CM-UFD.M33.............................. 2/54

1SVR450117R5100... CM-CT 300/5............................ 2/131

1SVR550127R4100... CT-ARE....................................... 1/20

1SVR700101R0100... C512-D..................................... 2/104

1SVR450117R5200... CM-CT 400/5............................ 2/131

1SVR550130R1100... CT-VWE. . ..................................... 1/20

1SVR700102R0100... C512-E. . .................................... 2/104

1SVR450117R5300... CM-CT 500/5............................ 2/131

1SVR550130R2100... CT-VWE. . ..................................... 1/20

1SVR700111R0100... C513-D..................................... 2/104

1SVR450117R5400... CM-CT 600/5............................ 2/131

1SVR550130R4100... CT-VWE. . ..................................... 1/20

1SVR700112R0100... C513-E. . .................................... 2/104

1SVR450118R1000... CM-CT A................................... 2/131

1SVR550137R1100... CT-VWE. . ..................................... 1/20

1SVR730005R0100... COV.11. . ...................................... 1/40

1SVR450330R0000... CM-LWN..................................... 2/76

1SVR550137R2100... CT-VWE. . ..................................... 1/20

1SVR730005R0100... COV.11. . .................................... 2/130

1SVR450330R0100... CM-LWN..................................... 2/76

1SVR550137R4100... CT-VWE. . ..................................... 1/20

1SVR730006R0000... MAR.12....................................... 1/40

1SVR450331R0000... CM-LWN..................................... 2/76

1SVR550140R1100... CT-AWE . . .................................... 1/21

1SVR730006R0000... MAR.12..................................... 2/130

1SVR450331R0100... CM-LWN..................................... 2/76

1SVR550140R2100... CT-AWE . . .................................... 1/21

1SVR730010R0200... CT-MFS.21.................................. 1/37

1SVR450332R0000... CM-LWN..................................... 2/76

1SVR550140R4100... CT-AWE . . .................................... 1/21

1SVR730010R3200... CT-MBS.22S. . .............................. 1/37

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/10

7

Index
Numerical
Order code

7

Type

Page

Order code

Type

Page

Order code

Type

Page

1SVR730020R0200... CT-MVS.21S................................ 1/37

1SVR730831R0400... CM-ESS.2S................................. 2/16

1SVR740712R1400... CM-MSS.31P.. ............................. 2/90

1SVR730020R3100... CT-MVS.12S................................ 1/37

1SVR730831R1300... CM-ESS.1S................................. 2/16

1SVR740712R2200... CM-MSS.33P.. ............................. 2/90

1SVR730020R3300... CT-MVS.22S................................ 1/37

1SVR730831R1400... CM-ESS.2S................................. 2/16

1SVR740720R1400... CM-MSS.11P.. ............................. 2/90

1SVR730021R2300... CT-MVS.23S................................ 1/37

1SVR730840R0200... CM-SRS.11S............................... 2/15

1SVR740722R1400... CM-MSS.21P.. ............................. 2/90

1SVR730030R3300... CT- MXS.22S............................... 1/37

1SVR730840R0300... CM-SRS.12S............................... 2/15

1SVR740740R0100... CM-TCS.11P ............................ 2/104

1SVR730040R3300... CT-WBS.22S............................... 1/37

1SVR730840R0400... CM-SRS.21S............................... 2/15

1SVR740740R0200... CM-TCS.12P ............................ 2/104

1SVR730100R0300... CT-ERS.21S................................ 1/38

1SVR730840R0500... CM-SRS.22S............................... 2/15

1SVR740740R0300... CM-TCS.13P ............................ 2/104

1SVR730100R3100... CT-ERS.12S................................ 1/38

1SVR730840R0600... CM-SRS.M1S.............................. 2/15

1SVR740740R9100... CM-TCS.21P ............................ 2/104

1SVR730100R3300... CT-ERS.22S................................ 1/38

1SVR730840R0700... CM-SRS.M2S.............................. 2/15

1SVR740740R9200... CM-TCS.22P ............................ 2/104

1SVR730110R3300... CT-AHS.22S................................ 1/38

1SVR730841R0200... CM-SRS.11S............................... 2/15

1SVR740740R9300... CM-TCS.23P ............................ 2/104

1SVR730120R3100... CT-ARS.11S................................ 1/38

1SVR730841R0300... CM-SRS.12S............................... 2/15

1SVR740750R0400... CM-EFS.2P................................. 2/16

1SVR730120R3300... CT-ARS.21S................................ 1/38

1SVR730841R0400... CM-SRS.21S............................... 2/15

1SVR740760R0400... CM-SFS.21P............................... 2/15

1SVR730180R0300... CT-APS.21S................................ 1/38

1SVR730841R0500... CM-SRS.22S............................... 2/15

1SVR740774R1300... CM-PAS.31P............................... 2/33

1SVR730180R3100... CT-APS.12S................................ 1/38

1SVR730841R1200... CM-SRS.11S............................... 2/15

1SVR740774R3300... CM-PAS.41P............................... 2/33

1SVR730180R3300... CT-APS.22S................................ 1/38

1SVR730841R1300... CM-SRS.12S............................... 2/15

1SVR740784R2300... CM-PSS.31P............................... 2/33

1SVR730210R3300... CT-SDS.22S................................ 1/38

1SVR730841R1400... CM-SRS.21S............................... 2/15

1SVR740784R3300... CM-PSS.41P............................... 2/33

1SVR730211R2300... CT-SDS.23S................................ 1/38

1SVR730841R1500... CM-SRS.22S............................... 2/15

1SVR740794R1300... CM-PVS.31P............................... 2/33

1SVR730660R0100... CM-IWS.1S.................................. 2/66

1SVR730884R1300... CM-MPS.31S.. ............................. 2/34

1SVR740794R2300... CM-PVS.81P............................... 2/33

1SVR730670R0200... CM-IWS.2S.................................. 2/66

1SVR730884R3300... CM-MPS.41S.. ............................. 2/34

1SVR740794R3300... CM-PVS.41P............................... 2/33

1SVR730700R0100... CM-MSS.12S.. ............................. 2/90

1SVR730884R4300... CM-MPS.43S.. ............................. 2/34

1SVR740824R9300... CM-PFS.P................................... 2/33

1SVR730700R0200... CM-MSS.22S.. ............................. 2/90

1SVR730885R1300... CM-MPS.11S.. ............................. 2/34

1SVR740830R0300... CM-ESS.1P................................. 2/16

1SVR730700R2100... CM-MSS.13S.. ............................. 2/90

1SVR730885R3300... CM-MPS.21S.. ............................. 2/34

1SVR740830R0400... CM-ESS.2P................................. 2/16

1SVR730700R2200... CM-MSS.23S.. ............................. 2/90

1SVR730885R4300... CM-MPS.23S.. ............................. 2/34

1SVR740830R0500... CM-ESS.MP................................ 2/16

1SVR730712R0200... CM-MSS.32S.. ............................. 2/90

1SVR740010R0200... CT-MFS.21P................................ 1/37

1SVR740831R0300... CM-ESS.1P................................. 2/16

1SVR730712R1200... CM-MSS.41S.. ............................. 2/90

1SVR740010R3200... CT-MBS.22P. . .............................. 1/37

1SVR740831R0400... CM-ESS.2P................................. 2/16

1SVR730712R1300... CM-MSS.51S.. ............................. 2/90

1SVR740020R0200... CT-MVS.21P................................ 1/37

1SVR740831R1300... CM-ESS.1P................................. 2/16

1SVR730712R1400... CM-MSS.31S.. ............................. 2/90

1SVR740020R3100... CT-MVS.12P................................ 1/37

1SVR740831R1400... CM-ESS.2P................................. 2/16

1SVR730712R2200... CM-MSS.33S.. ............................. 2/90

1SVR740020R3300... CT-MVS.22P................................ 1/37

1SVR740840R0200... CM-SRS.11P............................... 2/15

1SVR730720R1400... CM-MSS.11S.. ............................. 2/90

1SVR740021R2300... CT-MVS.23P................................ 1/37

1SVR740840R0400... CM-SRS.21P............................... 2/15

1SVR730722R1400... CM-MSS.21S.. ............................. 2/90

1SVR740030R3300... CT-MXS.22P................................ 1/37

1SVR740840R0600... CM-SRS.M1P.............................. 2/15

1SVR730740R0100... CM-TCS.11S ............................ 2/104

1SVR740040R3300... CT-WBS.22P............................... 1/37

1SVR740841R0200... CM-SRS.11P............................... 2/15

1SVR730740R0200... CM-TCS.12S ............................ 2/104

1SVR740100R0300... CT-ERS.21P................................ 1/38

1SVR740841R0400... CM-SRS.21P............................... 2/15

1SVR730740R0300... CM-TCS.13S ............................ 2/104

1SVR740100R3100... CT-ERS.12P................................ 1/38

1SVR740841R1200... CM-SRS.11P............................... 2/15

1SVR730740R9100... CM-TCS.21S ............................ 2/104

1SVR740100R3300... CT-ERS.22P................................ 1/38

1SVR740841R1400... CM-SRS.21P............................... 2/15

1SVR730740R9200... CM-TCS.22S ............................ 2/104

1SVR740110R3300... CT-AHS.22P................................ 1/38

1SVR740884R1300... CM-MPS.31P.. ............................. 2/34

1SVR730740R9300... CM-TCS.23S ............................ 2/104

1SVR740120R3100... CT-ARS.11P................................ 1/38

1SVR740884R3300... CM-MPS.41P.. ............................. 2/34

1SVR730750R0400... CM-EFS.2S................................. 2/16

1SVR740120R3300... CT-ARS.21P................................ 1/38

1SVR740884R4300... CM-MPS.43P.. ............................. 2/34

1SVR730760R0400... CM-SFS.21S............................... 2/15

1SVR740180R0300... CT-APS.21P................................ 1/38

1SVR740885R1300... CM-MPS.11P.. ............................. 2/34

1SVR730760R0500... CM-SFS.22S............................... 2/15

1SVR740180R3100... CT-APS.12P................................ 1/38

1SVR740885R3300... CM-MPS.21P.. ............................. 2/34

1SVR730774R1300... CM-PAS.31S............................... 2/33

1SVR740180R3300... CT-APS.22P................................ 1/38

1SVR740885R4300... CM-MPS.23P.. ............................. 2/34

1SVR730774R3300... CM-PAS.41S............................... 2/33

1SVR740210R3300... CT-SDS.22P................................ 1/38

1SVR750005R0100... COV.12. . .................................... 2/130

1SVR730784R2300... CM-PSS.31S............................... 2/33

1SVR740211R2300... CT-SDS.23P................................ 1/38

1SVR750487R8300... CM-MPN.52S.............................. 2/34

1SVR730784R3300... CM-PSS.41S............................... 2/33

1SVR740660R0100... CM-IWS.1P.. ................................ 2/66

1SVR750488R8300... CM-MPN.62S.............................. 2/34

1SVR730794R1300... CM-PVS.31S............................... 2/33

1SVR740670R0200... CM-IWS.2P.. ................................ 2/66

1SVR750489R8300... CM-MPN.72S.............................. 2/34

1SVR730794R2300... CM-PVS.81S............................... 2/33

1SVR740700R0100... CM-MSS.12P.. ............................. 2/90

1SVR750660R0200... CM-IWN.1S................................. 2/66

1SVR730794R3300... CM-PVS.41S............................... 2/33

1SVR740700R0200... CM-MSS.22P.. ............................. 2/90

1SVR750660R0300... CM-IWN.4S................................. 2/66

1SVR730824R9300... CM-PFS.S .................................. 2/33

1SVR740700R2100... CM-MSS.13P.. ............................. 2/90

1SVR750660R0400... CM-IWN.5S................................. 2/66

1SVR730830R0300... CM-ESS.1S................................. 2/16

1SVR740700R2200... CM-MSS.23P.. ............................. 2/90

1SVR750660R0500... CM-IWN.6S................................. 2/66

1SVR730830R0400... CM-ESS.2S................................. 2/16

1SVR740712R0200... CM-MSS.32P.. ............................. 2/90

1SVR750669R9400... CM-IVN.S.................................... 2/66

1SVR730830R0500... CM-ESS.MS................................ 2/16

1SVR740712R1200... CM-MSS.41P.. ............................. 2/90

1SVR760487R8300... CM-MPN.52P.............................. 2/34

1SVR730831R0300... CM-ESS.1S................................. 2/16

1SVR740712R1300... CM-MSS.51P.. ............................. 2/90

1SVR760488R8300... CM-MPN.62P.............................. 2/34

2/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210

Index
Numerical
Order code

Type

Page

1SVR760489R8300... CM-MPN.72P.............................. 2/34
1SVR760660R0200... CM-IWN.1P................................. 2/66
1SVR760660R0300... CM-IWN.4P................................. 2/66
1SVR760660R0400... CM-IWN.5P................................. 2/66
1SVR760660R0500... CM-IWN.6P................................. 2/66
1SVR760669R9400... CM-IVN.P.................................... 2/66

2CDE
2CDE601101R2001... EPD24-TB-101-1A....................... 3/75
2CDE601101R2002... EPD24-TB-101-2A....................... 3/75
2CDE601101R2003... EPD24-TB-101-3A....................... 3/75
2CDE601101R2004... EPD24-TB-101-4A....................... 3/75
2CDE601101R2006... EPD24-TB-101-6A....................... 3/75
2CDE601101R2008... EPD24-TB-101-8A....................... 3/75
2CDE601101R2010... EPD24-TB-101-10A..................... 3/75
2CDE601101R2012... EPD24-TB-101-12A..................... 3/75
2CDE601101R2905... EPD24-TB-101-0.5A.................... 3/75

7

2CDE605100R0500... EPD-BB500................................. 3/75
2CDE605200R0021... EPD-SB21................................... 3/75

GJD
GJD6155620R0087. .. SK 615 562-87............................ 1/39
GJD6155620R0088. .. SK 615 562-88............................ 1/39

2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/12

ABB STOTZ-KONTAKT GmbH
You can find the address of your local sales organisation
on the ABB homepage:
www.abb.com/contacts
> Low Voltage Products and Systems

Find out more about Electronic Products and Relays on:
http://new.abb.com/low-voltage/products/epr

Note: We reserve the right to make technical changes or
modify the contents of this document without prior notice.
With regard to purchase orders, the agreed particulars shall
prevail. ABB AG does not accept any responsibility whatsoever
for potential errors or possible lack of information in this document.
We reserve all rights in this document and in the subject matter
and illustrations contained therein. Any reproduction, disclosure
to third parties or utilization of its contents – in whole or in parts –
is forbidden without prior written consent of ABB AG.
Copyright © 2015 ABB
All rights reserved

DE ABB 2CDC 110 004 C0210 Rev A printed in Federal Republic of Germany (03/2015)

Contact us



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2015:03:16 14:33:24+01:00
Creator                         : Adobe InDesign CS6 (Windows)
Modify Date                     : 2015:03:16 14:40:04+01:00
Title                           : 
Trapped                         : False
Has XFA                         : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2015:03:16 14:40:04+01:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Format                          : application/pdf
Document ID                     : uuid:1e8fba64-0a40-4007-be56-d8ab22beae01
Instance ID                     : uuid:531a8095-3b90-45b4-a074-01e5ce8cabaa
Producer                        : Adobe PDF Library 10.0.1
Page Count                      : 424
EXIF Metadata provided by EXIF.tools

Navigation menu