Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:2 of 2 Date: Oct. 08, 2005 Table of Contents 1. DOCUMENT POLICY AND TEST STATEMENT ................................................ 5 1.1 DOCUMENT POLICY ........................................................................................ 5 1.2 TEST STATEMENT ............................................................................................ 5 2. DESCRIPTION OF EUT AND TEST MODE....................................................... 6 2.1 GENERAL DESCRIPTION OF EUT .................................................................. 6 2.2 DESCRIPTION OF EUT INTERNAL DEVICE.................................................... 6 2.3 DESCRIPTION OF TEST MODE ....................................................................... 7 3. DESCRIPTION OF APPLIED STANDARDS ...................................................... 7 4. EMISSION TEST ................................................................................................ 8 4.1 CONDUCTED EMISSION TEST FOR POWER PORT ...................................... 8 4.1.1 CONDUCTED EMISSION LIMIT........................................................................ 8 4.1.2 TEST EQUIPMENT............................................................................................ 8 4.1.3 TEST SETUP ..................................................................................................... 9 4.1.4 TEST PROCEDURE .......................................................................................... 9 4.1.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 10 4.1.6 EUT OPERATING CONDITION ....................................................................... 10 4.1.7 TEST RESULT ................................................................................................. 11 4.2 RADIATED EMISSION TEST........................................................................... 13 4.2.1 RADIATED EMISSION LIMIT........................................................................... 13 4.2.2 TEST EQUIPMENT.......................................................................................... 13 4.2.3 TEST SET-UP.................................................................................................. 14 4.2.4 TEST PROCEDURE ........................................................................................ 14 4.2.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 15 4.2.6 EUT OPERATING CONDITION ....................................................................... 15 4.2.7 TEST RESULT ................................................................................................. 16 4.3 CURRENT HARMONICS TEST....................................................................... 17 4.3.2 TEST EQUIPMENT.......................................................................................... 18 4.3.3 TEST SETUP ................................................................................................... 18 4.3.4 TEST PROCEDURE ........................................................................................ 18 4.3.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 18 4.3.6 EUT OPERATING CONDITION ....................................................................... 18 4.3.7 TEST RESULT ................................................................................................. 19 4.4 VOLTAGE FLUCTUATIONS .......................................................................... 20 4.4.1 LIMIT ............................................................................................................. 20 4.4.2 TEST EQUIPMENT.......................................................................................... 20 4.4.3 TEST PROCEDURE ........................................................................................ 20 4.4.4 TEST SETUP ................................................................................................... 21 4.4.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 21 4.4.6 EUT OPERATING CONDITION ....................................................................... 21 4.4.7 TEST RESULT ................................................................................................. 22 5. ELECTROSTATIC DISCHARGE IMMUNITY TEST ........................................... 23 5.1 TEST EQUIPMENT .......................................................................................... 23 5.2 TEST PROCEDURE ........................................................................................ 23 5.3 TEST SET-UP .................................................................................................. 24 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:3 of 3 Date: Oct. 08, 2005 5.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 25 5.5 EUT OPERATING CONDITION ....................................................................... 25 5.6 TEST CONDITION AND PERFORMANCE CRITERION ................................. 25 5.7 SUMMARY OF TEST RESULT ........................................................................ 26 6. RADIATED IMMUNITY TEST............................................................................. 27 6.1 TEST EQUIPMENT .......................................................................................... 27 6.2 TEST PROCEDURE ........................................................................................ 27 6.3 TEST SETUP ................................................................................................... 28 6.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 29 6.5 EUT OPERATING CONDITION ....................................................................... 29 6.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 29 6.7 TEST RESULT ................................................................................................. 29 7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST .......................... 30 7.1 TEST EQUIPMENT .......................................................................................... 30 7.2 TEST PROCEDURE ........................................................................................ 30 7.3 TEST SET-UP .................................................................................................. 31 7.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 31 7.5 EUT OPERATING CONDITION ....................................................................... 31 7.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 32 7.7 SUMMARY OF TEST RESULT ........................................................................ 32 8. SURGE TEST (POWER LINE)........................................................................... 33 8.1 TEST EQUIPMENT .......................................................................................... 33 8.2 TEST PROCEDURE ........................................................................................ 33 8.3 TEST SET-UP .................................................................................................. 33 8.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 33 8.5 EUT OPERATING CONDITION ....................................................................... 33 8.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 34 8.7 SUMMARY OF TEST RESULT ........................................................................ 34 9. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST...................... 35 9.1 TEST EQUIPMENT .......................................................................................... 35 9.2 TEST PROCEDURE ........................................................................................ 36 9.3 TEST SET-UP .................................................................................................. 36 9.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 36 9.5 EUT OPERATING CONDITION ....................................................................... 36 9.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 37 9.7 SUMMARY OF TEST RESULT ........................................................................ 37 10. POWER FREQUENCY MAGNETIC-FIELD TEST ........................................... 39 10.1 TEST EQUIPMENT ........................................................................................ 39 10.2 TEST PROCEDURE ...................................................................................... 39 10.3 TEST SET-UP ................................................................................................ 39 10.4 DESCRIPTION OF SUPPORT UNIT ............................................................. 39 10.5 EUT OPERATING CONDITION ..................................................................... 40 10.6 TEST CONDITION / PERFORMANCE CRITERIA ........................................ 40 10.7 SUMMARY OF TEST RESULT ...................................................................... 40 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 11. 11.1 11.2 11.3 11.4 11.5 11.6 11.7 12. 13. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:4 of 4 Date: Oct. 08, 2005 VOLTAGE DIPS, INTERRUPTS, VARIATIONS TEST ...................................... 41 TEST EQUIPMENT ........................................................................................ 41 TEST PROCEDURE....................................................................................... 41 TEST SET-UP ................................................................................................ 41 DESCRIPTION OF SUPPORT UNIT.............................................................. 41 EUT OPERATING CONDITION ..................................................................... 41 TEST CONDITION / PERFORMANCE CRITERIA......................................... 42 SUMMARY OF TEST RESULT ...................................................................... 42 PHOTOS OF TESTING .................................................................................... 43 TERMS OF ABRIVATION................................................................................. 52 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 1. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:5 of 5 Date: Oct. 08, 2005 DOCUMENT POLICY AND TEST STATEMENT 1.1 DOCUMENT POLICY - The report shall not be reproduced except in full, without the written approval of SRT Lab, Inc. - The report must not be used by the applicant to claim that the product is endorsed by NVLAP, TÜV, NEMKO and SRT. - The NVLAP logo applies only to the applicable standards specified in this report. 1.2 TEST STATEMENT - The test results in the report apply only to the unit tested by SRT Lab. - There was no deviation from the requirements of test standards during the test. - AC power source, 230 VAC/50 Hz, was used during the test. - The EN 61000-3-2:1995+A1:1998+A2:1998(Harmonic test) and EN 61000-3-3: 1995+A1:1998(Flicker test) are not included in the scope of NVLAP logo usage. - The EN 61000-3-2:1995+A1:1998+A2:1998(Harmonic test) and EN 61000-3-3: 1995+A1:1998(Flicker test) are included in the scope of TÜV, NEMKO and SRT logo usage. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:6 of 6 Date: Oct. 08, 2005 2. DESCRIPTION OF EUT AND TEST MODE 2.1 GENERAL DESCRIPTION OF EUT PRODUCT SATA CardBus MODEL NO. POWER SUPPLY CABLE PC-113,PC-113R,PC-112,PC-112R,ST-109R N/A N/A NOTE: The EUT consisted of one SATA card (presented in this report as EUT1) and one HDD (presented in this report as EUT2). For more detailed information, please refer to the EUT’s specification or user’s manual provided by manufacturer. 2.2 DESCRIPTION OF EUT INTERNAL DEVICE DEVICE BRAND / MAKER N/A NOTE : 1. The highest clock of EUT1 and EUT2 are 25MHz. 2. Frequency range to be measured. Radiated emission is 30 MHz to 1 GHz. MODEL # REMARK Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:7 of 7 Date: Oct. 08, 2005 2.3 DESCRIPTION OF TEST MODE The EUT was tested for emission measurement under the following situations: For certain test items, the test object is either EUT1 or EUT2. When either one represented the test object, the other was regarded as one of the support units. 3. DESCRIPTION OF APPLIED STANDARDS The EUT is a kind of ITE interface device and according to the specifications provided by the applicant, it must comply with the requirements of the following standards: EN 55022:1998, Class B EN 55024:1998 - IEC 61000-4-2:1995+A1:1998 EN 61000-3-2:1995+ A1:1998+A2:1998 - IEC 61000-4-3:1995+A1:1998 EN 61000-3-3:1995+A1:1998 - IEC 61000-4-4:1995 - IEC 61000-4-5:1995 - IEC 61000-4-6:1996 - IEC 61000-4-8:1993 - IEC 61000-4-11:1994 However, the standards of EN 61000-3-2, EN 61000-3-3, IEC 61000-4-5 and IEC 61000-4-11 were not measured for EUT1 for the power source of EUT1 is DC from PC. All tests have been performed and recorded as per the required standards. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 4. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:8 of 8 Date: Oct. 08, 2005 EMISSION TEST 4.1 CONDUCTED EMISSION TEST FOR POWER PORT 4.1.1 CONDUCTED EMISSION LIMIT Frequency (MHz) 0.15 - 0.5 Class A (dBµV) Quasi-peak Average 79 66 Class B (dBµV) Quasi-peak Average 66 - 56 56 - 46 0.50 - 5.0 73 60 56 46 5.0 - 30.0 73 60 60 50 NOTE: 1. The lower limit shall apply at the transition frequencies. 2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz. 4.1.2 TEST EQUIPMENT The following test equipment was used for the test: EQUIPMENT/ FACILITIES EMI TEST RECEIVER LISN (for EUT) LISN (for Peripheral) 50 ohm TERMINATOR COAXIAL CABLE ISOLATION TRANSFORMER FILTER SPECIFICATIONS MANUFACTURER 9 kHz TO 30 MHz 50 µH, 50 ohm 50µH, 50 ohm 50 ohm HP 3m SUNCITY N/A APC 2 LINE, 30A FIL.COIL 2.3M (H) x 2.4M (W) 2.4M (H) x GROUND PLANE 2.4M (W) GROUND PLANE ROHDE & SCHWARZ SOLAR ELECTRONICS SOLAR ELECTRONICS MODEL#/ SERIAL# ESHS30/ 826003/008 8012-50-R-24-BNC / 924839 9252-50-R-24-BNC / 951318 11593A/ 2 J400/ 3M AFC-11015/ F102040016 FC-943/ 771 SRT N/A SRT N/A DUE DATE OF CAL. & CAL. CENTER AUG. 2006 R&S JUN. 2006 ETC JUN. 2006 ETC MAY 2006 ETC JUL. 2006 SRT N/A N/A APR. 2006 SRT APR. 2006 SRT NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:9 of 9 Date: Oct. 08, 2005 4.1.3 TEST SETUP EMI TEST Receiver To Utility Power Coaxial Cable Isolation Transformer Filter LISN EUT LISN Support Units NOTE: 1. The EUT was put on a wooden table with 0.8m height above ground plane, and 0.4m away from reference ground plane (> 2mx2m). 2. For the actual test configuration, please refer to the photos of testing. 3. The serial no. of the LISN connected to EUT is 951318. 4. The serial no. of the LISN connected to support units is 924839. 4.1.4 TEST PROCEDURE The EUT was tested according to the requirement of EN 55022:1998. The frequency spectrum from 0.15 MHz to 30 MHz was investigated. The LISN used was 50Ω/50µH as specified. All readings were quasi-peak and average values with 10 kHz resolution bandwidth of the test receiver.The EUT system was operated in all typical methods by users. Both lines of the power mains of EUT were measured and the cables connected to EUT and support units were moved to find the maximum emission levels for each frequency. First, Find the margin or higher points at least 6 points by software, then use manual to find the maximum data. The procedure is referred on the test procedure of SRT LAB. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:10 of 10 Date: Oct. 08, 2005 4.1.5 DESCRIPTION OF SUPPORT UNIT The EUT was configured by the requirement of EN 55022:1998. All interface ports were connected to the appropriate support units via specific cables. The support units and cables are listed below. NO DEVICE BRAND MODEL # CABLE 1.5m unshielded power cord 1.2m shielded data cable 1.5m unshielded power cord 1.2m shielded data cable 1.5m unshielded DC power cable 1.2m shielded data cable 1 MONITOR SAMSUNG PG17IS 2 PRINTER EPSON STYLUS C20SX 3 MODEM ACEEX DM-1414 4 MOUSE LOGITECH MS-34 1.5m unshielded data cable 5 HDD HITACHI DK23CA-10 N/A 6 NOTEBOOK IBM 560Z 1.5m unshielded power cord 7 ADAPTOR WELLAND PA-213-50 1.5m unshielded power cord NOTE : For the actual test configuration, please refer to the photos of testing. 4.1.6 EUT OPERATING CONDITION 1. Under Windows 98 ran “EMI TEST” and “Ping.bat” programs and PC sent "H" pattern or accessed the following peripherals directly or via EUT: - Color Monitor - RS232 - Keyboard - Mouse - Printer - FDD - HDD 2. Under Windows XP run “XCOPY” program. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:11 of 11 Date: Oct. 08, 2005 4.1.7 TEST RESULT Temperature: 25 °C Humidity: 52 %RH Frequency Range: 0.15 – 30 MHz Test Object: EUT2 Receiver Detector: Q.P. and AV. Tested By: Tom Lin Tested Date: Aug. 25, 2003 Power Line Measured : Line Correct. Reading Value Emission Level Factor (dBµV) (dBµV) (dB) Q.P. AV. Q.P. AV. 0.205 0.20 48.8 45.6 49.0 45.8 Q.P. 63.4 AV. 53.4 Q.P. -14.4 AV. -7.6 0.509 0.20 45.8 45.3 46.0 45.5 56.0 46.0 -10.0 -0.5 0.607 0.20 40.8 39.7 41.0 39.9 56.0 46.0 -15.0 -6.1 2.029 0.20 43.1 42.7 43.3 42.9 56.0 46.0 -12.7 -3.1 3.654 0.26 44.9 41.2 45.2 41.5 56.0 46.0 -10.8 -4.5 5.884 0.33 48.5 46.2 48.8 46.5 60.0 50.0 -11.2 -3.5 Freq. (MHz) Limit (dBµV) Margin (dB) Power Line Measured : Neutral Correct. Reading Value Emission Level Factor (dBµV) (dBµV) (dB) Q.P. AV. Q.P. AV. 0.205 0.20 46.0 40.0 46.2 40.2 Q.P. 63.4 AV. 53.4 Q.P. -17.2 AV. -13.2 0.408 0.20 41.3 38.5 41.5 38.7 57.7 47.7 -16.2 -9.0 1.322 0.20 38.7 36.9 38.9 37.1 56.0 46.0 -17.1 -8.9 2.951 0.20 38.9 37.4 39.1 37.6 56.0 46.0 -16.9 -8.4 5.904 0.33 44.0 41.2 44.3 41.5 60.0 50.0 -15.7 -8.5 9.974 0.40 37.7 31.2 38.1 31.6 60.0 50.0 -21.9 -18.4 Freq. (MHz) Limit (dBµV) Margin (dB) NOTE : 1. Measurement uncertainty is +/-2dB 2. Emission level = Reading value + Correction factor 3. Correction Factor = Cable loss + Insertion loss of LISN 4. Margin value = Emission level - Limit 5. The emission of other frequencies were very low against the limit. 6. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:12 of 12 Date: Oct. 08, 2005 Temperature: 25 °C Humidity: 52 %RH Frequency Range: 0.15 – 30 MHz Test Object: EUT1 Receiver Detector: Q.P. and AV. Tested By: Tom Lin Tested Date: Aug. 25, 2003 Power Line Measured : Line Correct. Reading Value Emission Level Factor (dBµV) (dBµV) (dB) Q.P. AV. Q.P. AV. 0.162 0.20 53.6 52.5 53.8 52.7 Q.P. 65.4 AV. 55.4 Q.P. -11.6 AV. -2.7 0.420 0.20 40.1 34.8 40.3 35.0 57.4 47.4 -17.1 -12.4 0.740 0.20 39.2 28.9 39.4 29.1 56.0 46.0 -16.6 -16.9 2.623 0.20 37.4 25.4 37.6 25.6 56.0 46.0 -18.4 -20.4 8.529 0.37 42.0 31.1 42.4 31.5 60.0 50.0 -17.6 -18.5 19.236 0.58 42.9 36.4 43.5 37.0 60.0 50.0 -16.5 -13.0 Freq. (MHz) Limit (dBµV) Margin (dB) Power Line Measured : Neutral Correct. Reading Value Emission Level Factor (dBµV) (dBµV) (dB) Q.P. AV. Q.P. AV. 0.170 0.20 52.0 39.4 52.2 39.6 Q.P. 65.0 AV. 55.0 Q.P. -12.8 AV. -15.4 0.759 0.20 40.8 27.8 41.0 28.0 56.0 46.0 -15.0 -18.0 1.232 0.20 40.8 28.9 41.0 29.1 56.0 46.0 -15.0 -16.9 3.060 0.20 44.6 22.5 44.8 22.7 56.0 46.0 -11.2 -23.3 7.642 0.36 42.6 28.1 43.0 28.5 60.0 50.0 -17.0 -21.5 8.130 0.37 41.3 30.1 41.7 30.5 60.0 50.0 -18.3 -19.5 Freq. (MHz) Limit (dBµV) Margin (dB) NOTE : 1. Measurement uncertainty is +/-2dB 2. Emission level = Reading value + Correction factor 3. Correction Factor = Cable loss + Insertion loss of LISN 4. Margin value = Emission level - Limit 5. The emission of other frequencies were very low against the limit. 6. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:13 of 13 Date: Oct. 08, 2005 4.2 RADIATED EMISSION TEST 4.2.1 RADIATED EMISSION LIMIT EN 55022:1998 limits of radiated emission measurement for frequency below 1000 MHz Class A (at 10m) Class B (at 10m) dBµV/m dBµV/m 30 – 230 40 30 230 - 1000 47 37 FREQUENCY (MHz) NOTE: 1. The lower limit shall apply at the transition frequencies. 2. Emission level (dBµV/m) = 20 log Emission level (µV/m). 4.2.2 TEST EQUIPMENT The following test equipment was used during the radiated emission test: EQUIPMENT/ FACILITIES EMI TEST RECEIVER BI-LOG ANTENNA SPECIFICATIONS MANUFACTURER 20 MHz TO 1 GHz 25 MHz TO 2 GHz 3 – 10 M MEASUREMENT ROHDE & SCHWARZ COAXIAL CABLE 25M SUNCITY FILTER 2 LINE, 30A FIL.COIL FREQUENCY CONVERTER N/A APC OATS EMCO SRT MODEL#/ SERIAL# ESVS30/ 841977/003 3142/ 9701-1124 SRT-1 J400/ 25M FC-943/ 869 AFC-2KBB/ F100030031 DUE DATE OF CAL. & CAL. CENTER AUG. 2006 R&S APR. 2006 SRT APR. 2006 SRT AUG. 2006 SRT N/A AUG. 2006 SRT NOTE: 1. The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. 2. The Open Area Test Site (SRT-1) is registered by FCC with No. 90957 and VCCI with No. R-1081. 3. The Open Area Test Site (SRT-2) is registered by FCC with No. 98458 and VCCI with No. R-1168. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:14 of 14 Date: Oct. 08, 2005 4.2.3 TEST SET-UP Turn Table 1m – 4m EUT Coaxial Power Cable 0.8 m Cable 3/10m Filter To Utility Power Ground Plane EMI Receiver NOTE: 1. The EUT system was put on a wooden table with 0.8m heights above a ground plane. 2. For the actual test configuration, please refer to the photos of testing. 4.2.4 TEST PROCEDURE The EUT was tested according to the requirement of EN 55022:1998. The measurements were made at an open area test site with 10 meter measurement distance. The frequency spectrum measured from 30 MHz to 1 GHz. All readings were quasi-peak values with 120 kHz resolution bandwidth of the test receiver. The EUT system was operated in all typical methods by users. The cables connected to EUT and support units were moved to find the maximum emission levels for each frequency. First, Find the margin or higher points at least 6 points by software, then use manual to find the maximum data. The procedure is referred on the test procedure of SRT LAB. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT 4.2.5 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 4.2.6 EUT OPERATING CONDITION Same as section 4.1.6 of this report. Reference No.:A05100404 Report No.:EMCA03051901-02 Page:15 of 15 Date: Oct. 08, 2005 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:16 of 16 Date: Oct. 08, 2005 4.2.7 TEST RESULT Temperature: 25 °C Humidity: 50 %RH Frequency Range: 30 – 1000 MHz Measured Distance: 10m Receiver Detector: Q.P. Tested Object: EUT1+EUT2 Tested By: Tom Lin Tested Date: Aug. 25, 2003 Antenna Polarization: Horizontal Frequency Cable Antenna Reading Emission Limit Margin (dBµV/m) (dB) 26.7 30.0 15.2 25.2 14.42 13.8 2.51 16.89 601.4750 2.73 749.9555 2.98 Loss Factor Data Level (dB) (dB/m) (dBµV) (dBµV/m) 75.9600 1.09 7.10 18.5 149.9900 1.48 8.54 299.9850 2.06 449.9770 (MHz) AZ(°) EL(m) -3.3 254 4 30.0 -4.8 291 4 30.3 37.0 -6.7 98 4 12.1 31.5 37.0 -5.5 125 4 20.81 9.3 32.8 37.0 -4.2 61 4 22.78 11.0 36.8 37.0 -0.2 88 4 Limit Margin (dBµV/m) (dB) AZ(°) EL(m) Antenna Polarization: Vertical Frequency Cable Antenna Reading Emission Loss Factor Data Level (dB) (dB/m) (dBµV) (dBµV/m) 99.4152 1.12 8.34 17.5 27.0 30.0 -3.0 41 1 118.5284 1.32 7.54 13.8 22.7 30.0 -7.3 60 1 149.9900 1.48 8.54 18.2 28.2 30.0 -1.8 94 1 200.4970 1.63 9.90 10.5 22.0 30.0 -8.0 101 1 449.9773 2.51 16.89 13.4 32.8 37.0 -4.2 117 1 749.9623 2.98 22.78 8.9 34.7 37.0 -2.3 52 1 (MHz) NOTE : 1. Measurement uncertainty is +/-4dB. 2. "*": Measurement does not apply for this frequency. 3. Emissiom Level = Reading Value + Ant. Factor + Cable Loss. 4. The field strength of other emission frequencies were very low against the limit. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:17 of 17 Date: Oct. 08, 2005 4.3 CURRENT HARMONICS TEST 4.3.1 LIMIT For Class A Equipment EVEN HARMONICS ODD HARMONICS HARMONICS ORDER LIMIT (Amp.) HARMONICS ORDER LIMIT (Amp.) 2 1.08 3 2.30 4 0.43 5 1.14 6 0.30 7 0.77 8 < n < 40 0.23 x 8 / n 9 0.40 11 0.33 13 0.21 15 < n < 39 0.15 x 8 / n For Class D Equipment Harmonics Order n Max. permissible harmonics current per watt (mA/W) Max. permissible harmonics current (A) Odd Harmonics only 3 3.4 2.30 5 1.9 1.14 7 1.0 0.77 9 0.5 0.40 11 0.35 0.33 13 0.30 0.21 15 ≤ n ≤ 39 3.85 / n 0.15 x 15 / n NOTE: 1. Class A and Class D are judged by test equipment automatically as per Section 5 of EN 61000-3-2:1995 2. The above limits for Class D equipment are for all applications having an active input power > 75 W. No limits apply for equipment with an active input power up to and including 75 W. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:18 of 18 Date: Oct. 08, 2005 4.3.2 TEST EQUIPMENT EQUIPMENT / FACILITIES MAIN UNIT MODEL # / MANUFACTURER HP 6842A/ 3734A00212 DUE DATE OF CAL. & CAL. CENTER MAR. 2006 AGILENT NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. 4.3.3 TEST SETUP To utility power Harmonics/ Flicker tester EUT NOTE : 1. The EUT system was put on a wooden table with 0.8m high. 2. For the actual test configuration, please refer to the photos of testing. 4.3.4 TEST PROCEDURE According to EN61000-3-2:1995+A1:1998+A2:1998 4.3.5 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 4.3.6 EUT OPERATING CONDITION Same as section 4.1.6 of this report. Auxiliary Equipment Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:19 of 19 Date: Oct. 08, 2005 4.3.7 TEST RESULT Temperature: 26 °C Humidity: 46% RH Fundamental Current: Voltage: 0.033A 225.6Vrms Max. Power Consumption: 4.5W Power Factor: 0.308 Tested Object: EUT2 Tested By: Tom Lin Test Date: Aug. 25, 2003 Maximum Reading Data: Odd Harm. Order Reading Data (A) Limit (A) Test Result 3 0.0196 0.9 PASS Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 4.4 TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:20 of 20 Date: Oct. 08, 2005 VOLTAGE FLUCTUATIONS 4.4.1 LIMIT Short-team flicker (Pst) : 1.0 Long-term flicker (Plt) : 0.65 Relative steady-state voltage change (Dc) : ≤ 3% Relative voltage change characteristic (D (t) ) > 3% ; (TD(t)) : ≤ 200 ms Maximum relative voltage change (Dmax) : ≤ 4% TEST ITEM Pst LIMIT 1.0 NOTE Pst means short-term flicker indicator. Plt 0.65 Plt means long-term flicker indicator. TD(t) (ms) 200 TD(t) means maximum time that D (t) exceeds 3 %. Dmax (%) 4% Dmax means maximum relative voltage change. Dc (%) 3% Dc means relative steady-state voltage change 4.4.2 TEST EQUIPMENT EQUIPMENT / FACILITIES MAIN UNIT MANUFACTURER HP MODEL # / 6842A/ 3734A00212 DUE DATE OF CAL. & CAL. CENTER MAR. 2006 AGILENT NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. 4.4.3 TEST PROCEDURE According to EN 61000-3-3:1995+A1:1998 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:21 of 21 Date: Oct. 08, 2005 4.4.4 TEST SETUP To utility power Harmonics/ Flicker tester EUT Auxiliary Equipment NOTE : 1. The EUT system was put on a wooden table with 0.8m high. 2. For the actual test configuration, please refer to the photos of testing. 4.4.5 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 4.4.6 EUT OPERATING CONDITION Same as section 4.1.6 of this report. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:22 of 22 Date: Oct. 08, 2005 4.4.7 TEST RESULT Temperature: 26 °C Humidity: 46% RH Input Voltage: Ampere: 225.6Vrms 0.1Arms Observation Period: 1Hr Power Factor: 0.300 Tested Object: EUT2 Tested By: Tom Lin Test Date: Aug. 25, 2003 LIMIT TEST RESULT 1.0 PASS Test Result: Pst MEASUREMENT VALUE 0.07 Plt 0.07 0.65 PASS TD(t) (ms) 0 200 PASS Dmax (%) 0% 4% PASS Dc (%) 0% 3% PASS TEST PARAMETER NOTE: 1. Pst means short-term flicker indicator. 2. Plt means long-term flicker indicator. 3. TD(t) means maximum time that D(t) exceeds 3 %. 4. Dmax means maximum relative voltage change. 5. Dc means relative steady-state voltage change. 6. N/A: Not applicable. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:23 of 23 Date: Oct. 08, 2005 5. ELECTROSTATIC DISCHARGE IMMUNITY TEST 5.1 TEST EQUIPMENT EQUIPMENT / FACILITIES MANUFACTURER ESD SIMULATOR NOISEKEN HCP (1.6M x 0.8M) SRT VCP (0.5M x 0.5M) SRT GROUND PLANE (3.4M x 2.4M) SRT MODEL # / SERIAL # ESS-100L(A)/TC-815P/ 8099C02238/7099C02 WITH TWO 470k OHM CABLE WITH TWO 470k OHM CABLE DUE DATE OF CAL. & CAL. CENTER NOV. 2005 ETC APR. 2006 SRT APR. 2006 SRT N/A N/A NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. 5.2 TEST PROCEDURE According to IEC/EN 61000-4-2:1995+A1:1998 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Reference No.:A05100404 Report No.:EMCA03051901-02 Page:24 of 24 Date: Oct. 08, 2005 TEST REPORT 5.3 TEST SET-UP ESD Gun Vertical Coupling Plane 10 cm 470kΩ EUT System Insulating Support Wooden Table Horizontal Coupling Plane 470kΩ Return Cable Ground Reference Plane NOTE : 1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT. 2. For the actual test configuration, please refer to the photos of testing. 3. A distance of 1m minimum was provided between EUT and walls / other metallic structure. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:25 of 25 Date: Oct. 08, 2005 5.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 5.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. 5.6 TEST CONDITION AND PERFORMANCE CRITERION 1. Test condition (1) R-C Network (2) Test level: Air Discharge Contact discharge HCP discharge : VCP discharge : (3) Discharge mode (4) Discharge period (5) Discharge polarity (6) Number of discharge 2. Standard requirement 3. Performance criterion (1) Criterion A (2) Criterion B (3) Criterion C : 330 Ω, 150 pF : ±2kV, ±4kV, ±8kV : ±2kV, ±4kV ±2kV, ±4kV ±2kV, ±4kV : Single discharge : at least 1 s : Positive and Negative : Minimum 50 times at each test point of contact discharge and at least 200 times of discharge to EUT in total. Minium 10 times at each test area of air discharge selected. : Criterion B : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable : Temporary degradation or loss of function or performance which requires operator intervention system reset Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:26 of 26 Date: Oct. 08, 2005 5.7 SUMMARY OF TEST RESULT Temperature: 20 °C Humidity: 48% RH Test Object: EUT1+EUT2 Tested By: Tom Lin Atmospheric Air Pressure: 101.2 kPa Tested Date: Aug. 25, 2003 Test Result: Criterion B pass SEVERITY LEVEL COUPLING MODE & TEST OBSERVATION ±2kV AIR DISCHARGE A CONTACT DISCHARGE A ±4kV A ±8kV B HCP VCP A A B A A NR NR NR NOTE: Description of test observation: A: There was no change compared with initial operation during the test. B: The function of data copy was delayed during testing. NR: No requirement Description of test points: 1. Metallic part of SATA port on EUT1 & EUT2. 2. Screw of EUT2. 3. Case of EUT2. 4. HCP. 5. VCP. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:27 of 27 Date: Oct. 08, 2005 6. RADIATED IMMUNITY TEST 6.1 TEST EQUIPMENT EQUIPMENT / FACILITIES SIGNAL GENERATOR ANTENNA FIELD SENSOR POWER AMPLIFIER ANECHOIC CHAMBER HP SCHAFFNER CHASE AMPLIFIER RESEARCH AMPLIFIER RESEARCH SRT V/M MONITOR A.R. MONITOR SHIN CCD TOPVIEW ABSORBER ETS COAXIAL CABLE COAXIAL CABLE MODEL # / SERIAL # MANUFACTURER SUNCITY TIME DUE DATE OF CAL. & CAL. CENTER 8648A/ 3636A022776 JUN. 2006 ETC CBL6111/ 1188 FP2000/ 28499 100W1000M1/ 19509 A05/ SRT005 FM2000/ 15970 SI-609/ 905130 N/A/ 95113762 AUG. 2006 SRT DEC. 2005 ETC JUN. 2006 ETC SEP. 2006 SRT N/A N/A J400/ 30CM LMR-400/ 4M APR. 2006 SRT APR. 2006 SRT N/A N/A N/A NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. 6.2 TEST PROCEDURE According to IEC/EN 61000-4-3:1995+A1:1998 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Reference No.:A05100404 Report No.:EMCA03051901-02 Page:28 of 28 Date: Oct. 08, 2005 TEST REPORT 6.3 TEST SETUP Absorber Sensor EUT CCD 1.5m Absorber 0.8 m Wooden table Coaxial Cable 3m Power V/M Signal Amplifier Optical Fiber Monitor Monitor Generator NOTE : 1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT. 2. For the actual test configuration, please refer to the photos of testing. 1.1m door balun to Absorber/Tile Ant. 2.75m Absorber Location 1.5m 2.2m 1.85m chamber (7m x 3m x 3m) 0.24m Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:29 of 29 Date: Oct. 08, 2005 6.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 6.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. 6.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Source voltage and frequency : 230V/50Hz, single phase (2) Sweeping frequency : 80MHz – 1 GHz (3) Test level : 3V/m, the frequncy step is 1% (4) The four sides of EUT are tested : front, rear, left, right (5) Modulation : 80%AM, 1kHz Dwell time for each frequency is 3 sec. (6) Antenna Polarization : Horizontal and Vertical (7) Standard requirement : Criterion A 2. Performance criterion (1) Criterion A (2) Criterion B (3) Criterion C : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable. : Temporary degradation or loss of function or performance which requires operator intervention system reset. 6.7 TEST RESULT Temperature: Test Object: 24°C EUT1+EUT2 Humidity: Tested By: Tested Date: 56% RH Tom Lin Aug. 13, 2003 Test Result : Criterion A pass MODULATION DIRECTION TEST RESULT (CRITERION) H V FREQUENCY LEVEL 80MHz - 1GHz 3V/m 80%AM, 1kHz FRONT A A 80MHz - 1GHz 3V/m 80%AM, 1kHz REAR A A 80MHz - 1GHz 3V/m 80%AM, 1kHz LEFT A A 80MHz - 1GHz 3V/m 80%AM, 1kHz RIGHT A A NOTE: Description of test observation: A: There was no change compared with initial operation during the test. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:30 of 30 Date: Oct. 08, 2005 7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST 7.1 TEST EQUIPMENT EQUIPMENT / FACILITIES MODEL # / SERIAL # MANUFACTURER DUE DATE OF CAL & CAL CENTER EFT GENERATOR HAEFELY PEFT-JUNIOR / 583-333-122 NOV. 2005 ETC CLAMP HAEFELY TRENCH / 080421-12 NOV. 2005 ETC GROUND PLANE 2M x 3M SRT N/A APR. 2006 SRT 7.2 TEST PROCEDURE According to IEC/EN 61000-4-4:1995 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:31 of 31 Date: Oct. 08, 2005 7.3 TEST SET-UP Power Auxiliary EUT Equipment Clamp Auxiliary Equipment EFT Wave Generator I/O and communication ports Load EUT EFT Wave Power Cable Generator Auxiliary Equipment Power supply ports NOTE : 1. The EUT system was put on a wooden table with 0.8m height for table top EUT and 0.1m for floor-standing EUT above ground reference plane. 2. For the actual test configuration, please refer to the photos of testing. 3. The minimum distance between the EUT and all other conductive structure was more than 0.5m. 4. The minimum distance between the coupling plates of the coupling clamps (if used) and all over conductive structures, except the ground plane beneath the coupling clamp and beneath the EUT was more than 0.5m. 5. The power cable connecting EUT was controlled under 1m. 7.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 7.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Reference No.:A05100404 Report No.:EMCA03051901-02 Page:32 of 32 Date: Oct. 08, 2005 TEST REPORT 7.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Source voltage and frequency (2) Pulse risetime and duration (3) Pulse repetition (4) Polarity : 230V/50Hz, single phase : 5ns / 50ns : 5kHz : Positive Polarization and Negative Polarization : 15ms / 300ms : 61sec each line : 10Sec : Power Line ±1kV Signal/Control Line ±0.5kV : Criterion B (5) Burst duration and period (6) Test duration (7) Time between test (8) Severity levels (9) Standard requirement 2. Performance criterion (1) Criterion A (2) Criterion B : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable. : Temporary degradation or loss of function or performance which requires operator intervention system reset. (3) Criterion C 7.7 SUMMARY OF TEST RESULT Temperature: 24 °C Humidity: 54% RH Test Object: EUT1+EUT2 Tested By: Tom Lin Atmospheric Air Pressure: 101.2 kPa Tested Date: Aug. 13, 2003 Test Result : Criterion A pass Voltage 0.5kV Polarity Test Line 1kV + - + - L1 A A A A L2 A A A A GND A A A A Signal/ Control Line NR NR NR NR NOTE: Description of test observation: A: There was no change compared with initial operation during the test. NR: No requirement Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:33 of 33 Date: Oct. 08, 2005 8. SURGE TEST (POWER LINE) 8.1 TEST EQUIPMENT EQUIPMENT / FACILITIES SURGE TEST (System Mainframe) SURGE TEST (Impulse Network) SURGE TEST (Pulse Coupling Network) MANUFACTURER SCHAFFNER SCHAFFNER SCHAFFNER MODEL # / SERIAL # DUE DATE OF CAL. & CAL. CENTER NSG 2050 / 199904-057SC OCT. 2005 ETC PNW 2050 / 256 CDN 131/133 / 520 OCT. 2005 ETC OCT. 2005 ETC 8.2 TEST PROCEDURE According to IEC/EN 61000-4-5:1995 8.3 TEST SET-UP SURGE GENERATOR EUT Auxiliary Equipment NOTE : 1. The EUT system was put on a wooden table with 0.8m height above ground reference plane. 2. For the actual test configuration, please refer to the photos of testing. 8.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 8.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Reference No.:A05100404 Report No.:EMCA03051901-02 Page:34 of 34 Date: Oct. 08, 2005 TEST REPORT 8.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Test level (2) (3) (4) (5) (6) (7) : Common mode : ±0.5kV, ±1kV, ±2kV Differential mode : ±0.25kV, ±0.5kV, ±1kV :5 : 0°, 90°, 180°, 270° : Positive and Negative polarization : 60 s : 1.2/50 µs (open circuit) : Criterion B Number of Pulse Phase Polarity Repetition Waveform Standard requirement 2. Performance criterion (1) Criterion A (2) Criterion B : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable : Temporary degradation or loss of function or performance which requires operator intervention system reset (3) Criterion C 8.7 SUMMARY OF TEST RESULT Temperature: 24 °C Humidity: 58% RH Test Object: EUT2 Tested By: Tom Lin Atmospheric Air Pressure: 101.2 kPa Tested Date: Aug. 13, 2003 Test Result : Criterion A pass Mode Common Differential Coupling L + PE N + PE L+N Voltage Phase 0° 90° 180° 270° +/-0.5kV A A A A +/-1kV A A A A +/-2kV A A A A +/-0.25kV A A A A +/-0.5kV A A A A +/-1kV A A A A NOTE: Description of test observation: A: There was no change compared with initial operation during the test. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:35 of 35 Date: Oct. 08, 2005 9. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST 9.1 TEST EQUIPMENT EQUIPMENT / FACILITIES MANUFACTURER EM INJECTION CLAMP FCC POWER LINE CDN FCC POWER LINE CDN FCC POWER LINE CDN FCC SIGNAL LINE CDN FCC SIGNAL LINE CDN FCC SIGNAL LINE CDN FCC SIGNAL LINE CDN FCC POWER LINE CDN FCC SIGNAL GENERATOR MODEL # / SERIAL # FINAL DUE DATE OF CAL. TEST BE & CAL. CENTER USED F-203I-23mm/ 110 MAY 2006 ETC FCC-801-M4-32A/ 9808 FCC-801-M5-32A/ 9812 FCC-801-M1-32A/ 9820 FCC-801-T2/ 9830 FCC-801-T4/ 9831 MAY 2006 ETC MAY 2006 ETC MAY 2006 ETC MAY 2006 ETC MAY 2006 ETC FCC-801-T6/ 9832 MAY 2006 ETC FCC-801-S9/ 9843 FCC-801-M2-32A/ 9840 MAY 2006 ETC NOV. 2005 ETC HP 8648A/ 3636A02776 JUN. 2006 ETC √ POWER AMPLIFIER A.R. 150A100A/ 19553 MAY 2006 ETC √ DUAL DIRECTION COULPER A.R. DC2600/ 25893 SEP. 2006 ETC √ POWER METER BOONTON 4232A/ 29001 MAY 2006 ETC √ SIGNAL LINE CDN FCC FCC-801-S25/ 9845 MAY 2006 ETC POWER LINE CDN FCC T2 EM-TEST COAXIAL CABLE SUNCITY COAXIAL CABLE SUNCITY COAXIAL CABLE SUNCITY FCC-801-M3-32A/ 9874 ATT6/75/ 1001-40 CABLE14/ #14-1M CABLE05/ #5-5M J400/ 2M MAY 2006 ETC N/A APR. 2006 SRT APR. 2006 SRT APR. 2006 SRT √ √ √ √ √ Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:36 of 36 Date: Oct. 08, 2005 9.2 TEST PROCEDURE According to IEC/EN 61000-4-6:1996 9.3 TEST SET-UP (1) For CDN injection : EUT Coaxial SIGNAL Cable GENERATOR Power T2 CDN Amplifier Auxiliary Equipment (2) For Clamp injection : EUT Monitoring Probe Coaxial SIGNAL GENERATOR Cable Power Amplifier T2 Injection Receiver Clamp Auxiliary Equipment NOTE : 1. The EUT system was put on a wooden table with 0.1m height above ground. 2. For the actual test configuration, please refer to the photos of testing. 3. The distance between CDN(Clamp) and EUT was controlled between 0.1m and 0.3m. 4. The model no. of the CDN connected to EUT is FCC-801-M3-32A. 9.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 9.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Reference No.:A05100404 Report No.:EMCA03051901-02 Page:37 of 37 Date: Oct. 08, 2005 TEST REPORT 9.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Source voltage and frequency (2) Sweeping frequency (3) Test level (4) Modulation (5) Dwell time for each frequency (6) Standard requirement 2. Performance criterion (1) Criterion A (2) Criterion B : 230 V/ 50 Hz, single phase : 150 kHz – 80 MHz : 3 V, the frequency step is 1% : AM 80%, 1 kHz : 3 sec : Criterion A : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable : Temporary degradation or loss of function or performance which requires operator intervention system reset (3) Criterion C 9.7 SUMMARY OF TEST RESULT Temperature: 24°C Humidity: 51% RH Test Object: EUT1 Tested By: Tom Lin Test Result : Criterion A pass Tested Date: Aug. 13, 2003 FREQUENCY LEVEL 150kHz - 80MHz 3V MODULATION 80% AM, 1 kHz INJECTION METHOD TEST RESULT (CRITERION) M3 A NOTE: Description of test observation: A: There was no change compared with initial operation during the test. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Reference No.:A05100404 Report No.:EMCA03051901-02 Page:38 of 38 Date: Oct. 08, 2005 TEST REPORT Temperature: 24°C Humidity: 51% RH Test Object: EUT2 Tested By: Tom Lin Test Result : Criterion A pass Tested Date: Aug. 13, 2003 FREQUENCY LEVEL 150kHz - 80MHz 3V MODULATION 80% AM, 1 kHz INJECTION METHOD TEST RESULT (CRITERION) M2 A NOTE: Description of test observation: A: There was no change compared with initial operation during the test. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Reference No.:A05100404 Report No.:EMCA03051901-02 Page:39 of 39 Date: Oct. 08, 2005 TEST REPORT 10. POWER FREQUENCY MAGNETIC-FIELD TEST 10.1 TEST EQUIPMENT EQUIPMENT / FACILITIES MAGNETIC FIELD TESTER MAGNETIC FIELD COIL HAEFELY MAGNETIC FIELD METER F.W.BELL MANUFACTURER HAEFELY MODEL # / SERIAL # MAG 100.1/ 080.015-04 MAG 100.1/ 080.015-04 DUE DATE OF CAL. & CAL. CENTER JAN. 2006 SRT JAN. 2006 SRT 4080/ 19990416 MAR. 2006 ITRI 10.2 TEST PROCEDURE According to IEC/EN 61000-4-8:1993 10.3 TEST SET-UP Magnetic Coil EUT Test Generator Frequency Converter NOTE : 1. The EUT system was put on a wooden table with 0.8m height above ground. 2. For the actual test configuration, please refer to the photos of testing 3. 1A/m = 12.56mG, 3A/m = 37.68mG, 10A/m = 125.6mG, 10.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:40 of 40 Date: Oct. 08, 2005 10.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. 10.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Test axis (2) Test time (3) Field strength (4) Standard requirement : X, Y and Z axes : 5 min / each axis : 3 A/m : Criterion A 2. Performance criterion (1) Criterion A (2) Criterion B : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable : Temporary degradation or loss of function or performance which requires operator intervention system reset (3) Criterion C 10.7 SUMMARY OF TEST RESULT Temperature: 24°C Humidity: 54%H Test Object: EUT1+EUT2 Tested By: Tom Lin Frequency of Magnetic Field: ■50Hz, □60Hz Tested Date: Aug. 14, 2003 Test Result : Criterion A pass ORIENTATION FIELD STRENGTH TEST RESULT (CRITERION) X 3 A/m A Y 3 A/m A Z 3 A/m A NOTE: Description of test observation: A: There was no change compared with initial operation during the test. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:41 of 41 Date: Oct. 08, 2005 11. VOLTAGE DIPS, INTERRUPTS, VARIATIONS TEST 11.1 TEST EQUIPMENT EQUIPMENT / FACILITIES INTERFERENCE SIMULATOR MANUFACTURER HAEFELY MODEL # / SERIAL # PLINE 1610/ 083-732-05 DUE DATE OF CAL. & CAL. CENTER APR. 2006 ETC 11.2 TEST PROCEDURE According to IEC/EN 61000-4-11:1994 11.3 TEST SET-UP Frequency Interference Converter Simulator Power cable EUT NOTE : 1. The EUT system was put on a wooden table with 0.8m height above ground. 2. For the actual test configuration, please refer to the photos of testing. 11.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 11.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. Auxiliary Equipment Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:42 of 42 Date: Oct. 08, 2005 11.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Source voltage and frequency (2) Test level (3) (4) (5) (6) Phase Test duration Time between test Standard requirement 2. Performance criterion (1) Criterion A (2) Criterion B : 230V/50Hz, single phase : Dip depth 95%, 0.5 period 30%, 25 period Interrupt 95%, 250 period : 0°, 180° : 2min each phase : 10 sec : Dip 95% : Criterion B; Dip 30% : Criterion C; Interrupt > 95%: Criterion C : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable. : Temporary degradation or loss of function or performance which requires operator intervention system reset. (3) Criterion C 11.7 SUMMARY OF TEST RESULT Temperature: 24°C Humidity: 54% RH Test Object: EUT2 Tested By: Tom Lin Tested Date: Aug. 14, 2003 AC POWER 230V/50Hz DIP DEPTH INTERVAL DIP TIME TEST TIME 95% 10 sec 0.5 period 2 min 30% 10 sec 25 period 2 min 95% (interrupt) 10 sec 250 period 2 min PHASE 0° 180° 0° 180° 0° 180° TEST RESULT (Criterion) A A A A B B NOTE: 1. The power voltage range: 100V to 240V, and the range 140V is 140% of the lowest voltage. 2. Description of test observation: A: There was no change compared with initial operation during the test. B: EUT delayed in data copy during testing. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 12. PHOTOS OF TESTING - Conducted test (EUT1) TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:43 of 43 Date: Oct. 08, 2005 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. - Conducted test (EUT2) TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:44 of 44 Date: Oct. 08, 2005 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. - Radiated test (EUT1+EUT2) TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:45 of 45 Date: Oct. 08, 2005 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT - Harmonics test (EUT2) - Voltage fluctuations test (EUT2) Reference No.:A05100404 Report No.:EMCA03051901-02 Page:46 of 46 Date: Oct. 08, 2005 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:47 of 47 Date: Oct. 08, 2005 - Electrostatic discharge immunity test (EUT1+EUT2) - Electrical fast transient / burst immunity test (EUT1+EUT2) Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT - Radiated immunity test (EUT1+EUT2) Reference No.:A05100404 Report No.:EMCA03051901-02 Page:48 of 48 Date: Oct. 08, 2005 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT -Surge test (power line) (EUT2) - Inducted RF fields (conducted susceptibility) test (EUT1) Reference No.:A05100404 Report No.:EMCA03051901-02 Page:49 of 49 Date: Oct. 08, 2005 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT - Inducted RF fields (conducted susceptibility) test (EUT2) - Power frequency magnetic-field test (EUT1+EUT2) Reference No.:A05100404 Report No.:EMCA03051901-02 Page:50 of 50 Date: Oct. 08, 2005 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT - Voltage dips, interrupts, variations test (EUT2) Reference No.:A05100404 Report No.:EMCA03051901-02 Page:51 of 51 Date: Oct. 08, 2005 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.:A05100404 Report No.:EMCA03051901-02 Page:52 of 52 Date: Oct. 08, 2005 13. TERMS OF ABRIVATION AV. Average detection AZ(°) Turn table azimuth Correct. Correction EL(m) Antenna height (meter) EUT Equipment Under Test Horiz. Horizontal direction LISN Line Impedance Stabilization Network NSA Normalized Site Attenuation Q.P. Quasi-peak detection SRT Lab Spectrum Research & Testing Laboratory, Inc. Vert. Vertical direction
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 5.0.5 (Windows) Create Date : 2005:10:11 09:40:57Z Modify Date : 2009:01:15 10:54:51+08:00 Metadata Date : 2009:01:15 10:54:51+08:00 Format : application/pdf Document ID : uuid:91fe6070-0f16-4877-bfd2-73e00be145ec Instance ID : uuid:bd2a8f6c-545e-401a-b8c6-fb628953cfe7 Page Count : 52EXIF Metadata provided by EXIF.tools