Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:2 of 2
Date: Oct. 08, 2005

Table of Contents
1.
DOCUMENT POLICY AND TEST STATEMENT ................................................ 5
1.1 DOCUMENT POLICY ........................................................................................ 5
1.2 TEST STATEMENT ............................................................................................ 5
2.
DESCRIPTION OF EUT AND TEST MODE....................................................... 6
2.1 GENERAL DESCRIPTION OF EUT .................................................................. 6
2.2 DESCRIPTION OF EUT INTERNAL DEVICE.................................................... 6
2.3 DESCRIPTION OF TEST MODE ....................................................................... 7
3.
DESCRIPTION OF APPLIED STANDARDS ...................................................... 7
4.
EMISSION TEST ................................................................................................ 8
4.1 CONDUCTED EMISSION TEST FOR POWER PORT ...................................... 8
4.1.1 CONDUCTED EMISSION LIMIT........................................................................ 8
4.1.2 TEST EQUIPMENT............................................................................................ 8
4.1.3 TEST SETUP ..................................................................................................... 9
4.1.4 TEST PROCEDURE .......................................................................................... 9
4.1.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 10
4.1.6 EUT OPERATING CONDITION ....................................................................... 10
4.1.7 TEST RESULT ................................................................................................. 11
4.2 RADIATED EMISSION TEST........................................................................... 13
4.2.1 RADIATED EMISSION LIMIT........................................................................... 13
4.2.2 TEST EQUIPMENT.......................................................................................... 13
4.2.3 TEST SET-UP.................................................................................................. 14
4.2.4 TEST PROCEDURE ........................................................................................ 14
4.2.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 15
4.2.6 EUT OPERATING CONDITION ....................................................................... 15
4.2.7 TEST RESULT ................................................................................................. 16
4.3 CURRENT HARMONICS TEST....................................................................... 17
4.3.2 TEST EQUIPMENT.......................................................................................... 18
4.3.3 TEST SETUP ................................................................................................... 18
4.3.4 TEST PROCEDURE ........................................................................................ 18
4.3.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 18
4.3.6 EUT OPERATING CONDITION ....................................................................... 18
4.3.7 TEST RESULT ................................................................................................. 19
4.4 VOLTAGE FLUCTUATIONS .......................................................................... 20
4.4.1 LIMIT ............................................................................................................. 20
4.4.2 TEST EQUIPMENT.......................................................................................... 20
4.4.3 TEST PROCEDURE ........................................................................................ 20
4.4.4 TEST SETUP ................................................................................................... 21
4.4.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 21
4.4.6 EUT OPERATING CONDITION ....................................................................... 21
4.4.7 TEST RESULT ................................................................................................. 22
5. ELECTROSTATIC DISCHARGE IMMUNITY TEST ........................................... 23
5.1 TEST EQUIPMENT .......................................................................................... 23
5.2 TEST PROCEDURE ........................................................................................ 23
5.3 TEST SET-UP .................................................................................................. 24

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:3 of 3
Date: Oct. 08, 2005

5.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 25
5.5 EUT OPERATING CONDITION ....................................................................... 25
5.6 TEST CONDITION AND PERFORMANCE CRITERION ................................. 25
5.7 SUMMARY OF TEST RESULT ........................................................................ 26
6. RADIATED IMMUNITY TEST............................................................................. 27
6.1 TEST EQUIPMENT .......................................................................................... 27
6.2 TEST PROCEDURE ........................................................................................ 27
6.3 TEST SETUP ................................................................................................... 28
6.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 29
6.5 EUT OPERATING CONDITION ....................................................................... 29
6.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 29
6.7 TEST RESULT ................................................................................................. 29
7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST .......................... 30
7.1 TEST EQUIPMENT .......................................................................................... 30
7.2 TEST PROCEDURE ........................................................................................ 30
7.3 TEST SET-UP .................................................................................................. 31
7.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 31
7.5 EUT OPERATING CONDITION ....................................................................... 31
7.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 32
7.7 SUMMARY OF TEST RESULT ........................................................................ 32
8. SURGE TEST (POWER LINE)........................................................................... 33
8.1 TEST EQUIPMENT .......................................................................................... 33
8.2 TEST PROCEDURE ........................................................................................ 33
8.3 TEST SET-UP .................................................................................................. 33
8.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 33
8.5 EUT OPERATING CONDITION ....................................................................... 33
8.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 34
8.7 SUMMARY OF TEST RESULT ........................................................................ 34
9. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST...................... 35
9.1 TEST EQUIPMENT .......................................................................................... 35
9.2 TEST PROCEDURE ........................................................................................ 36
9.3 TEST SET-UP .................................................................................................. 36
9.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 36
9.5 EUT OPERATING CONDITION ....................................................................... 36
9.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 37
9.7 SUMMARY OF TEST RESULT ........................................................................ 37
10. POWER FREQUENCY MAGNETIC-FIELD TEST ........................................... 39
10.1 TEST EQUIPMENT ........................................................................................ 39
10.2 TEST PROCEDURE ...................................................................................... 39
10.3 TEST SET-UP ................................................................................................ 39
10.4 DESCRIPTION OF SUPPORT UNIT ............................................................. 39
10.5 EUT OPERATING CONDITION ..................................................................... 40
10.6 TEST CONDITION / PERFORMANCE CRITERIA ........................................ 40
10.7 SUMMARY OF TEST RESULT ...................................................................... 40

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

11.
11.1
11.2
11.3
11.4
11.5
11.6
11.7
12.
13.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:4 of 4
Date: Oct. 08, 2005

VOLTAGE DIPS, INTERRUPTS, VARIATIONS TEST ...................................... 41
TEST EQUIPMENT ........................................................................................ 41
TEST PROCEDURE....................................................................................... 41
TEST SET-UP ................................................................................................ 41
DESCRIPTION OF SUPPORT UNIT.............................................................. 41
EUT OPERATING CONDITION ..................................................................... 41
TEST CONDITION / PERFORMANCE CRITERIA......................................... 42
SUMMARY OF TEST RESULT ...................................................................... 42
PHOTOS OF TESTING .................................................................................... 43
TERMS OF ABRIVATION................................................................................. 52

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

1.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:5 of 5
Date: Oct. 08, 2005

DOCUMENT POLICY AND TEST STATEMENT

1.1 DOCUMENT POLICY
-

The report shall not be reproduced except in full, without the written approval of
SRT Lab, Inc.

-

The report must not be used by the applicant to claim that the product is endorsed
by NVLAP, TÜV, NEMKO and SRT.

-

The NVLAP logo applies only to the applicable standards specified in this report.

1.2 TEST STATEMENT
-

The test results in the report apply only to the unit tested by SRT Lab.

-

There was no deviation from the requirements of test standards during the test.

-

AC power source, 230 VAC/50 Hz, was used during the test.

-

The EN 61000-3-2:1995+A1:1998+A2:1998(Harmonic test) and EN 61000-3-3:
1995+A1:1998(Flicker test) are not included in the scope of NVLAP logo usage.

-

The EN 61000-3-2:1995+A1:1998+A2:1998(Harmonic test) and EN 61000-3-3:
1995+A1:1998(Flicker test) are included in the scope of TÜV, NEMKO and SRT
logo usage.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:6 of 6
Date: Oct. 08, 2005

2. DESCRIPTION OF EUT AND TEST MODE
2.1 GENERAL DESCRIPTION OF EUT
PRODUCT

SATA CardBus

MODEL NO.
POWER SUPPLY
CABLE

PC-113,PC-113R,PC-112,PC-112R,ST-109R
N/A
N/A

NOTE:
The EUT consisted of one SATA card (presented in this report as EUT1) and one HDD (presented in this
report as EUT2).
For more detailed information, please refer to the EUT’s specification or user’s manual provided by
manufacturer.

2.2 DESCRIPTION OF EUT INTERNAL DEVICE
DEVICE

BRAND / MAKER

N/A

NOTE :
1. The highest clock of EUT1 and EUT2 are 25MHz.
2. Frequency range to be measured.
Radiated emission is 30 MHz to 1 GHz.

MODEL #

REMARK

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:7 of 7
Date: Oct. 08, 2005

2.3 DESCRIPTION OF TEST MODE
The EUT was tested for emission measurement under the following situations:
For certain test items, the test object is either EUT1 or EUT2. When either one
represented the test object, the other was regarded as one of the support units.
3. DESCRIPTION OF APPLIED STANDARDS
The EUT is a kind of ITE interface device and according to the specifications provided
by the applicant, it must comply with the requirements of the following standards:
EN 55022:1998, Class B
EN 55024:1998
- IEC 61000-4-2:1995+A1:1998
EN 61000-3-2:1995+ A1:1998+A2:1998
- IEC 61000-4-3:1995+A1:1998
EN 61000-3-3:1995+A1:1998
- IEC 61000-4-4:1995
- IEC 61000-4-5:1995
- IEC 61000-4-6:1996
- IEC 61000-4-8:1993
- IEC 61000-4-11:1994
However, the standards of EN 61000-3-2, EN 61000-3-3, IEC 61000-4-5 and IEC
61000-4-11 were not measured for EUT1 for the power source of EUT1 is DC from PC.
All tests have been performed and recorded as per the required standards.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

4.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:8 of 8
Date: Oct. 08, 2005

EMISSION TEST

4.1 CONDUCTED EMISSION TEST FOR POWER PORT
4.1.1 CONDUCTED EMISSION LIMIT
Frequency (MHz)
0.15 - 0.5

Class A (dBµV)
Quasi-peak
Average
79
66

Class B (dBµV)
Quasi-peak
Average
66 - 56
56 - 46

0.50 - 5.0

73

60

56

46

5.0 - 30.0

73

60

60

50

NOTE:
1. The lower limit shall apply at the transition frequencies.
2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.

4.1.2 TEST EQUIPMENT
The following test equipment was used for the test:
EQUIPMENT/
FACILITIES
EMI TEST
RECEIVER
LISN (for EUT)
LISN
(for Peripheral)
50 ohm
TERMINATOR
COAXIAL
CABLE
ISOLATION
TRANSFORMER
FILTER

SPECIFICATIONS MANUFACTURER
9 kHz TO
30 MHz
50 µH, 50 ohm
50µH, 50 ohm
50 ohm

HP

3m

SUNCITY

N/A

APC

2 LINE, 30A

FIL.COIL

2.3M (H) x
2.4M (W)
2.4M (H) x
GROUND PLANE
2.4M (W)
GROUND PLANE

ROHDE &
SCHWARZ
SOLAR
ELECTRONICS
SOLAR
ELECTRONICS

MODEL#/
SERIAL#
ESHS30/
826003/008
8012-50-R-24-BNC
/ 924839
9252-50-R-24-BNC
/ 951318
11593A/
2
J400/
3M
AFC-11015/
F102040016
FC-943/
771

SRT

N/A

SRT

N/A

DUE DATE OF CAL.
& CAL. CENTER
AUG. 2006
R&S
JUN. 2006
ETC
JUN. 2006
ETC
MAY 2006
ETC
JUL. 2006
SRT
N/A
N/A
APR. 2006
SRT
APR. 2006
SRT

NOTE: The calibration interval of the above test equipment is one year and the calibrations are
traceable to NML/ROC and NIST/USA.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:9 of 9
Date: Oct. 08, 2005

4.1.3 TEST SETUP
EMI TEST
Receiver

To Utility
Power

Coaxial Cable

Isolation
Transformer

Filter

LISN

EUT

LISN

Support Units

NOTE:
1. The EUT was put on a wooden table with 0.8m height above ground plane, and 0.4m away from
reference ground plane (> 2mx2m).
2. For the actual test configuration, please refer to the photos of testing.
3. The serial no. of the LISN connected to EUT is 951318.
4. The serial no. of the LISN connected to support units is 924839.

4.1.4 TEST PROCEDURE
The EUT was tested according to the requirement of EN 55022:1998. The frequency
spectrum from 0.15 MHz to 30 MHz was investigated. The LISN used was 50Ω/50µH
as specified. All readings were quasi-peak and average values with 10 kHz resolution
bandwidth of the test receiver.The EUT system was operated in all typical methods by
users. Both lines of the power mains of EUT were measured and the cables connected
to EUT and support units were moved to find the maximum emission levels for each
frequency.
First, Find the margin or higher points at least 6 points by software, then use manual to
find the maximum data. The procedure is referred on the test procedure of SRT LAB.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:10 of 10
Date: Oct. 08, 2005

4.1.5 DESCRIPTION OF SUPPORT UNIT
The EUT was configured by the requirement of EN 55022:1998. All interface ports were
connected to the appropriate support units via specific cables. The support units and
cables are listed below.
NO

DEVICE

BRAND

MODEL #

CABLE
1.5m unshielded power cord
1.2m shielded data cable
1.5m unshielded power cord
1.2m shielded data cable
1.5m unshielded DC power cable
1.2m shielded data cable

1

MONITOR

SAMSUNG

PG17IS

2

PRINTER

EPSON

STYLUS C20SX

3

MODEM

ACEEX

DM-1414

4

MOUSE

LOGITECH

MS-34

1.5m unshielded data cable

5

HDD

HITACHI

DK23CA-10

N/A

6

NOTEBOOK

IBM

560Z

1.5m unshielded power cord

7

ADAPTOR

WELLAND

PA-213-50

1.5m unshielded power cord

NOTE : For the actual test configuration, please refer to the photos of testing.

4.1.6 EUT OPERATING CONDITION
1. Under Windows 98 ran “EMI TEST” and “Ping.bat” programs and PC sent "H" pattern
or accessed the following peripherals directly or via EUT:
- Color Monitor
- RS232
- Keyboard
- Mouse
- Printer
- FDD
- HDD
2. Under Windows XP run “XCOPY” program.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:11 of 11
Date: Oct. 08, 2005

4.1.7 TEST RESULT
Temperature:

25 °C

Humidity:

52 %RH

Frequency Range:

0.15 – 30 MHz

Test Object:

EUT2

Receiver Detector:

Q.P. and AV.

Tested By:

Tom Lin

Tested Date:

Aug. 25, 2003

Power Line Measured : Line
Correct. Reading Value Emission Level
Factor
(dBµV)
(dBµV)
(dB)
Q.P.
AV.
Q.P.
AV.
0.205
0.20
48.8
45.6
49.0
45.8

Q.P.
63.4

AV.
53.4

Q.P.
-14.4

AV.
-7.6

0.509

0.20

45.8

45.3

46.0

45.5

56.0

46.0

-10.0

-0.5

0.607

0.20

40.8

39.7

41.0

39.9

56.0

46.0

-15.0

-6.1

2.029

0.20

43.1

42.7

43.3

42.9

56.0

46.0

-12.7

-3.1

3.654

0.26

44.9

41.2

45.2

41.5

56.0

46.0

-10.8

-4.5

5.884

0.33

48.5

46.2

48.8

46.5

60.0

50.0

-11.2

-3.5

Freq.
(MHz)

Limit
(dBµV)

Margin
(dB)

Power Line Measured : Neutral
Correct. Reading Value Emission Level
Factor
(dBµV)
(dBµV)
(dB)
Q.P.
AV.
Q.P.
AV.
0.205
0.20
46.0
40.0
46.2
40.2

Q.P.
63.4

AV.
53.4

Q.P.
-17.2

AV.
-13.2

0.408

0.20

41.3

38.5

41.5

38.7

57.7

47.7

-16.2

-9.0

1.322

0.20

38.7

36.9

38.9

37.1

56.0

46.0

-17.1

-8.9

2.951

0.20

38.9

37.4

39.1

37.6

56.0

46.0

-16.9

-8.4

5.904

0.33

44.0

41.2

44.3

41.5

60.0

50.0

-15.7

-8.5

9.974

0.40

37.7

31.2

38.1

31.6

60.0

50.0

-21.9

-18.4

Freq.
(MHz)

Limit
(dBµV)

Margin
(dB)

NOTE :
1. Measurement uncertainty is +/-2dB
2. Emission level = Reading value + Correction factor
3. Correction Factor = Cable loss + Insertion loss of LISN
4. Margin value = Emission level - Limit
5. The emission of other frequencies were very low against the limit.
6. "-": The Quasi-peak reading value also meets average limit and measurement with the average
detector is unnecessary.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:12 of 12
Date: Oct. 08, 2005

Temperature:

25 °C

Humidity:

52 %RH

Frequency Range:

0.15 – 30 MHz

Test Object:

EUT1

Receiver Detector:

Q.P. and AV.

Tested By:

Tom Lin

Tested Date:

Aug. 25, 2003

Power Line Measured : Line
Correct. Reading Value Emission Level
Factor
(dBµV)
(dBµV)
(dB)
Q.P.
AV.
Q.P.
AV.
0.162
0.20
53.6
52.5
53.8
52.7

Q.P.
65.4

AV.
55.4

Q.P.
-11.6

AV.
-2.7

0.420

0.20

40.1

34.8

40.3

35.0

57.4

47.4

-17.1

-12.4

0.740

0.20

39.2

28.9

39.4

29.1

56.0

46.0

-16.6

-16.9

2.623

0.20

37.4

25.4

37.6

25.6

56.0

46.0

-18.4

-20.4

8.529

0.37

42.0

31.1

42.4

31.5

60.0

50.0

-17.6

-18.5

19.236

0.58

42.9

36.4

43.5

37.0

60.0

50.0

-16.5

-13.0

Freq.
(MHz)

Limit
(dBµV)

Margin
(dB)

Power Line Measured : Neutral
Correct. Reading Value Emission Level
Factor
(dBµV)
(dBµV)
(dB)
Q.P.
AV.
Q.P.
AV.
0.170
0.20
52.0
39.4
52.2
39.6

Q.P.
65.0

AV.
55.0

Q.P.
-12.8

AV.
-15.4

0.759

0.20

40.8

27.8

41.0

28.0

56.0

46.0

-15.0

-18.0

1.232

0.20

40.8

28.9

41.0

29.1

56.0

46.0

-15.0

-16.9

3.060

0.20

44.6

22.5

44.8

22.7

56.0

46.0

-11.2

-23.3

7.642

0.36

42.6

28.1

43.0

28.5

60.0

50.0

-17.0

-21.5

8.130

0.37

41.3

30.1

41.7

30.5

60.0

50.0

-18.3

-19.5

Freq.
(MHz)

Limit
(dBµV)

Margin
(dB)

NOTE :
1. Measurement uncertainty is +/-2dB
2. Emission level = Reading value + Correction factor
3. Correction Factor = Cable loss + Insertion loss of LISN
4. Margin value = Emission level - Limit
5. The emission of other frequencies were very low against the limit.
6. "-": The Quasi-peak reading value also meets average limit and measurement with the average
detector is unnecessary.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:13 of 13
Date: Oct. 08, 2005

4.2 RADIATED EMISSION TEST
4.2.1 RADIATED EMISSION LIMIT
EN 55022:1998 limits of radiated emission measurement for frequency below 1000
MHz
Class A (at 10m)

Class B (at 10m)

dBµV/m

dBµV/m

30 – 230

40

30

230 - 1000

47

37

FREQUENCY (MHz)

NOTE:
1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBµV/m) = 20 log Emission level (µV/m).

4.2.2 TEST EQUIPMENT
The following test equipment was used during the radiated emission test:
EQUIPMENT/
FACILITIES
EMI TEST
RECEIVER
BI-LOG
ANTENNA

SPECIFICATIONS MANUFACTURER
20 MHz TO
1 GHz
25 MHz TO
2 GHz
3 – 10 M
MEASUREMENT

ROHDE &
SCHWARZ

COAXIAL
CABLE

25M

SUNCITY

FILTER

2 LINE, 30A

FIL.COIL

FREQUENCY
CONVERTER

N/A

APC

OATS

EMCO
SRT

MODEL#/
SERIAL#
ESVS30/
841977/003
3142/
9701-1124
SRT-1
J400/
25M
FC-943/
869
AFC-2KBB/
F100030031

DUE DATE OF CAL. &
CAL. CENTER
AUG. 2006
R&S
APR. 2006
SRT
APR. 2006
SRT
AUG. 2006
SRT
N/A
AUG. 2006
SRT

NOTE:
1. The calibration interval of the above test equipment is one year and the calibrations are traceable to
NML/ROC and NIST/USA.
2. The Open Area Test Site (SRT-1) is registered by FCC with No. 90957 and VCCI with No. R-1081.
3. The Open Area Test Site (SRT-2) is registered by FCC with No. 98458 and VCCI with No. R-1168.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:14 of 14
Date: Oct. 08, 2005

4.2.3 TEST SET-UP

Turn Table
1m – 4m

EUT
Coaxial
Power Cable

0.8 m

Cable

3/10m
Filter

To Utility
Power

Ground Plane
EMI Receiver

NOTE:
1. The EUT system was put on a wooden table with 0.8m heights above a ground plane.
2. For the actual test configuration, please refer to the photos of testing.

4.2.4 TEST PROCEDURE
The EUT was tested according to the requirement of EN 55022:1998. The
measurements were made at an open area test site with 10 meter measurement
distance. The frequency spectrum measured from 30 MHz to 1 GHz. All readings were
quasi-peak values with 120 kHz resolution bandwidth of the test receiver. The EUT
system was operated in all typical methods by users. The cables connected to EUT and
support units were moved to find the maximum emission levels for each frequency.
First, Find the margin or higher points at least 6 points by software, then use manual to
find the maximum data. The procedure is referred on the test procedure of SRT LAB.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

4.2.5 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.

4.2.6 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:15 of 15
Date: Oct. 08, 2005

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:16 of 16
Date: Oct. 08, 2005

4.2.7 TEST RESULT
Temperature:

25 °C

Humidity:

50 %RH

Frequency Range:

30 – 1000 MHz

Measured Distance:

10m

Receiver Detector:

Q.P.

Tested Object:

EUT1+EUT2

Tested By:

Tom Lin

Tested Date:

Aug. 25, 2003

Antenna Polarization: Horizontal
Frequency

Cable Antenna Reading Emission

Limit

Margin

(dBµV/m)

(dB)

26.7

30.0

15.2

25.2

14.42

13.8

2.51

16.89

601.4750

2.73

749.9555

2.98

Loss

Factor

Data

Level

(dB)

(dB/m)

(dBµV)

(dBµV/m)

75.9600

1.09

7.10

18.5

149.9900

1.48

8.54

299.9850

2.06

449.9770

(MHz)

AZ(°)

EL(m)

-3.3

254

4

30.0

-4.8

291

4

30.3

37.0

-6.7

98

4

12.1

31.5

37.0

-5.5

125

4

20.81

9.3

32.8

37.0

-4.2

61

4

22.78

11.0

36.8

37.0

-0.2

88

4

Limit

Margin

(dBµV/m)

(dB)

AZ(°)

EL(m)

Antenna Polarization: Vertical
Frequency

Cable Antenna Reading Emission
Loss

Factor

Data

Level

(dB)

(dB/m)

(dBµV)

(dBµV/m)

99.4152

1.12

8.34

17.5

27.0

30.0

-3.0

41

1

118.5284

1.32

7.54

13.8

22.7

30.0

-7.3

60

1

149.9900

1.48

8.54

18.2

28.2

30.0

-1.8

94

1

200.4970

1.63

9.90

10.5

22.0

30.0

-8.0

101

1

449.9773

2.51

16.89

13.4

32.8

37.0

-4.2

117

1

749.9623

2.98

22.78

8.9

34.7

37.0

-2.3

52

1

(MHz)

NOTE :
1. Measurement uncertainty is +/-4dB.
2. "*": Measurement does not apply for this frequency.
3. Emissiom Level = Reading Value + Ant. Factor + Cable Loss.
4. The field strength of other emission frequencies were very low against the limit.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:17 of 17
Date: Oct. 08, 2005

4.3 CURRENT HARMONICS TEST
4.3.1 LIMIT
For Class A Equipment
EVEN HARMONICS

ODD HARMONICS

HARMONICS
ORDER

LIMIT (Amp.)

HARMONICS
ORDER

LIMIT (Amp.)

2

1.08

3

2.30

4

0.43

5

1.14

6

0.30

7

0.77

8 < n < 40

0.23 x 8 / n

9

0.40

11

0.33

13

0.21

15 < n < 39

0.15 x 8 / n

For Class D Equipment
Harmonics Order
n

Max. permissible harmonics
current per watt (mA/W)

Max. permissible harmonics
current (A)

Odd Harmonics only
3

3.4

2.30

5

1.9

1.14

7

1.0

0.77

9

0.5

0.40

11

0.35

0.33

13

0.30

0.21

15 ≤ n ≤ 39

3.85 / n

0.15 x 15 / n

NOTE:
1. Class A and Class D are judged by test equipment automatically as per Section 5 of
EN 61000-3-2:1995
2. The above limits for Class D equipment are for all applications having an active input power > 75 W.
No limits apply for equipment with an active input power up to and including 75 W.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:18 of 18
Date: Oct. 08, 2005

4.3.2 TEST EQUIPMENT
EQUIPMENT /
FACILITIES
MAIN UNIT

MODEL # /

MANUFACTURER
HP

6842A/
3734A00212

DUE DATE OF CAL.
& CAL. CENTER
MAR. 2006
AGILENT

NOTE: The calibration interval of the above test equipment is one year and the calibrations are
traceable to NML/ROC and NIST/USA.

4.3.3 TEST SETUP
To utility power

Harmonics/
Flicker tester

EUT

NOTE :
1. The EUT system was put on a wooden table with 0.8m high.
2. For the actual test configuration, please refer to the photos of testing.

4.3.4 TEST PROCEDURE
According to EN61000-3-2:1995+A1:1998+A2:1998

4.3.5 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.

4.3.6 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.

Auxiliary
Equipment

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:19 of 19
Date: Oct. 08, 2005

4.3.7 TEST RESULT
Temperature:

26 °C

Humidity:

46% RH

Fundamental Current:
Voltage:

0.033A
225.6Vrms

Max. Power
Consumption:

4.5W

Power Factor:

0.308

Tested Object:

EUT2

Tested By:

Tom Lin

Test Date:

Aug. 25, 2003

Maximum Reading Data:
Odd
Harm. Order

Reading Data (A)

Limit (A)

Test Result

3

0.0196

0.9

PASS

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

4.4

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:20 of 20
Date: Oct. 08, 2005

VOLTAGE FLUCTUATIONS

4.4.1 LIMIT
Short-team flicker (Pst) : 1.0
Long-term flicker (Plt) : 0.65
Relative steady-state voltage change (Dc) : ≤ 3%
Relative voltage change characteristic (D (t) ) > 3% ; (TD(t)) : ≤ 200 ms
Maximum relative voltage change (Dmax) : ≤ 4%
TEST ITEM
Pst

LIMIT
1.0

NOTE
Pst means short-term flicker indicator.

Plt

0.65

Plt means long-term flicker indicator.

TD(t) (ms)

200

TD(t) means maximum time that D (t) exceeds 3 %.

Dmax (%)

4%

Dmax means maximum relative voltage change.

Dc (%)

3%

Dc means relative steady-state voltage change

4.4.2 TEST EQUIPMENT
EQUIPMENT /
FACILITIES
MAIN UNIT

MANUFACTURER
HP

MODEL # /
6842A/
3734A00212

DUE DATE OF CAL.
& CAL. CENTER
MAR. 2006
AGILENT

NOTE: The calibration interval of the above test equipment is one year and the calibrations are
traceable to NML/ROC and NIST/USA.

4.4.3 TEST PROCEDURE
According to EN 61000-3-3:1995+A1:1998

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:21 of 21
Date: Oct. 08, 2005

4.4.4 TEST SETUP
To utility power

Harmonics/
Flicker tester

EUT

Auxiliary
Equipment

NOTE : 1. The EUT system was put on a wooden table with 0.8m high.
2. For the actual test configuration, please refer to the photos of testing.

4.4.5 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.

4.4.6 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:22 of 22
Date: Oct. 08, 2005

4.4.7 TEST RESULT
Temperature:

26 °C

Humidity:

46% RH

Input Voltage:
Ampere:

225.6Vrms
0.1Arms

Observation
Period:

1Hr

Power Factor:

0.300

Tested Object:

EUT2

Tested By:

Tom Lin

Test Date:

Aug. 25, 2003

LIMIT

TEST RESULT

1.0

PASS

Test Result:

Pst

MEASUREMENT
VALUE
0.07

Plt

0.07

0.65

PASS

TD(t) (ms)

0

200

PASS

Dmax (%)

0%

4%

PASS

Dc (%)

0%

3%

PASS

TEST PARAMETER

NOTE:
1. Pst means short-term flicker indicator.
2. Plt means long-term flicker indicator.
3. TD(t) means maximum time that D(t) exceeds 3 %.
4. Dmax means maximum relative voltage change.
5. Dc means relative steady-state voltage change.
6. N/A: Not applicable.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:23 of 23
Date: Oct. 08, 2005

5. ELECTROSTATIC DISCHARGE IMMUNITY TEST
5.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES

MANUFACTURER

ESD SIMULATOR

NOISEKEN

HCP (1.6M x 0.8M)

SRT

VCP (0.5M x 0.5M)

SRT

GROUND PLANE
(3.4M x 2.4M)

SRT

MODEL # /
SERIAL #
ESS-100L(A)/TC-815P/
8099C02238/7099C02
WITH TWO 470k OHM
CABLE
WITH TWO 470k OHM
CABLE

DUE DATE OF CAL.
& CAL. CENTER
NOV. 2005
ETC
APR. 2006
SRT
APR. 2006
SRT

N/A

N/A

NOTE: The calibration interval of the above test equipment is one year and the calibrations are
traceable to NML/ROC and NIST/USA.

5.2 TEST PROCEDURE
According to IEC/EN 61000-4-2:1995+A1:1998

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:24 of 24
Date: Oct. 08, 2005

TEST REPORT

5.3 TEST SET-UP
ESD Gun

Vertical Coupling Plane
10 cm

470kΩ

EUT System
Insulating Support

Wooden Table
Horizontal Coupling
Plane

470kΩ

Return
Cable
Ground Reference Plane
NOTE :
1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT.
2. For the actual test configuration, please refer to the photos of testing.
3. A distance of 1m minimum was provided between EUT and walls / other metallic structure.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:25 of 25
Date: Oct. 08, 2005

5.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.

5.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.

5.6 TEST CONDITION AND PERFORMANCE CRITERION
1. Test condition
(1) R-C Network
(2) Test level: Air Discharge
Contact discharge
HCP discharge :
VCP discharge :
(3) Discharge mode
(4) Discharge period
(5) Discharge polarity
(6) Number of discharge

2. Standard requirement
3. Performance criterion
(1) Criterion A
(2) Criterion B
(3) Criterion C

: 330 Ω, 150 pF
: ±2kV, ±4kV, ±8kV
: ±2kV, ±4kV
±2kV, ±4kV
±2kV, ±4kV
: Single discharge
: at least 1 s
: Positive and Negative
: Minimum 50 times at each test point of contact
discharge and at least 200 times of discharge to
EUT in total. Minium 10 times at each test area
of air discharge selected.
: Criterion B
: Normal performance during test
: Temporary degradation or loss of function or
performance which is self-recoverable
: Temporary degradation or loss of function or
performance which requires operator
intervention system reset

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:26 of 26
Date: Oct. 08, 2005

5.7 SUMMARY OF TEST RESULT
Temperature:

20 °C

Humidity:

48% RH

Test Object:

EUT1+EUT2

Tested By:

Tom Lin

Atmospheric Air Pressure:

101.2 kPa

Tested Date:

Aug. 25, 2003

Test Result: Criterion B pass
SEVERITY
LEVEL

COUPLING MODE & TEST OBSERVATION

±2kV

AIR
DISCHARGE
A

CONTACT
DISCHARGE
A

±4kV

A

±8kV

B

HCP

VCP

A

A

B

A

A

NR

NR

NR

NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
B: The function of data copy was delayed during testing.
NR: No requirement

Description of test points:
1. Metallic part of SATA port on EUT1 & EUT2.
2. Screw of EUT2.
3. Case of EUT2.
4. HCP.
5. VCP.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:27 of 27
Date: Oct. 08, 2005

6. RADIATED IMMUNITY TEST
6.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES
SIGNAL
GENERATOR
ANTENNA
FIELD SENSOR
POWER
AMPLIFIER
ANECHOIC
CHAMBER

HP
SCHAFFNER
CHASE
AMPLIFIER
RESEARCH
AMPLIFIER
RESEARCH
SRT

V/M MONITOR

A.R.

MONITOR

SHIN

CCD

TOPVIEW

ABSORBER

ETS

COAXIAL
CABLE
COAXIAL
CABLE

MODEL # /
SERIAL #

MANUFACTURER

SUNCITY
TIME

DUE DATE OF CAL.
& CAL. CENTER

8648A/
3636A022776

JUN. 2006
ETC

CBL6111/
1188
FP2000/
28499
100W1000M1/
19509
A05/
SRT005
FM2000/
15970
SI-609/
905130
N/A/
95113762

AUG. 2006
SRT
DEC. 2005
ETC
JUN. 2006
ETC
SEP. 2006
SRT

N/A

N/A

J400/
30CM
LMR-400/
4M

APR. 2006
SRT
APR. 2006
SRT

N/A
N/A
N/A

NOTE: The calibration interval of the above test equipment is one year and the calibrations are
traceable to NML/ROC and NIST/USA.

6.2 TEST PROCEDURE
According to IEC/EN 61000-4-3:1995+A1:1998

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:28 of 28
Date: Oct. 08, 2005

TEST REPORT

6.3 TEST SETUP

Absorber

Sensor

EUT
CCD

1.5m
Absorber

0.8 m

Wooden
table

Coaxial Cable

3m

Power

V/M

Signal

Amplifier

Optical Fiber

Monitor

Monitor

Generator

NOTE :
1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT.
2. For the actual test configuration, please refer to the photos of testing.

1.1m
door
balun to Absorber/Tile

Ant.
2.75m

Absorber Location

1.5m
2.2m

1.85m
chamber (7m x 3m x 3m)

0.24m

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:29 of 29
Date: Oct. 08, 2005

6.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
6.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
6.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency
: 230V/50Hz, single phase
(2) Sweeping frequency
: 80MHz – 1 GHz
(3) Test level
: 3V/m, the frequncy step is 1%
(4) The four sides of EUT are tested : front, rear, left, right
(5) Modulation
: 80%AM, 1kHz Dwell time for each
frequency is 3 sec.
(6) Antenna Polarization
: Horizontal and Vertical
(7) Standard requirement
: Criterion A
2. Performance criterion
(1) Criterion A
(2) Criterion B
(3) Criterion C

: Normal performance during test
: Temporary degradation or loss of function or
performance which is self-recoverable.
: Temporary degradation or loss of function
or performance which requires operator
intervention system reset.

6.7 TEST RESULT
Temperature:
Test Object:

24°C
EUT1+EUT2

Humidity:
Tested By:
Tested Date:

56% RH
Tom Lin
Aug. 13, 2003

Test Result : Criterion A pass
MODULATION

DIRECTION

TEST RESULT
(CRITERION)
H
V

FREQUENCY

LEVEL

80MHz - 1GHz

3V/m

80%AM,

1kHz

FRONT

A

A

80MHz - 1GHz

3V/m

80%AM,

1kHz

REAR

A

A

80MHz - 1GHz

3V/m

80%AM,

1kHz

LEFT

A

A

80MHz - 1GHz

3V/m

80%AM,

1kHz

RIGHT

A

A

NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:30 of 30
Date: Oct. 08, 2005

7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST
7.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES

MODEL # /
SERIAL #

MANUFACTURER

DUE DATE OF CAL &
CAL CENTER

EFT GENERATOR

HAEFELY

PEFT-JUNIOR /
583-333-122

NOV. 2005
ETC

CLAMP

HAEFELY

TRENCH /
080421-12

NOV. 2005
ETC

GROUND PLANE
2M x 3M

SRT

N/A

APR. 2006
SRT

7.2 TEST PROCEDURE
According to IEC/EN 61000-4-4:1995

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:31 of 31
Date: Oct. 08, 2005

7.3 TEST SET-UP
Power
Auxiliary

EUT

Equipment
Clamp

Auxiliary
Equipment
EFT Wave
Generator

I/O and communication ports

Load

EUT

EFT Wave
Power Cable

Generator

Auxiliary
Equipment

Power supply ports
NOTE :
1. The EUT system was put on a wooden table with 0.8m height for table top EUT and 0.1m for
floor-standing EUT above ground reference plane.
2. For the actual test configuration, please refer to the photos of testing.
3. The minimum distance between the EUT and all other conductive structure was more than 0.5m.
4. The minimum distance between the coupling plates of the coupling clamps (if used) and all over
conductive structures, except the ground plane beneath the coupling clamp and beneath the EUT was
more than 0.5m.
5. The power cable connecting EUT was controlled under 1m.

7.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.

7.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:32 of 32
Date: Oct. 08, 2005

TEST REPORT

7.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency
(2) Pulse risetime and duration
(3) Pulse repetition
(4) Polarity

: 230V/50Hz, single phase
: 5ns / 50ns
: 5kHz
: Positive Polarization and Negative
Polarization
: 15ms / 300ms
: 61sec each line
: 10Sec
: Power Line ±1kV
Signal/Control Line ±0.5kV
: Criterion B

(5) Burst duration and period
(6) Test duration
(7) Time between test
(8) Severity levels
(9) Standard requirement
2. Performance criterion
(1) Criterion A
(2) Criterion B

: Normal performance during test
: Temporary degradation or loss of function or
performance which is self-recoverable.
: Temporary degradation or loss of function
or performance which requires operator
intervention system reset.

(3) Criterion C

7.7 SUMMARY OF TEST RESULT
Temperature:

24 °C

Humidity:

54% RH

Test Object:

EUT1+EUT2

Tested By:

Tom Lin

Atmospheric Air Pressure:

101.2 kPa

Tested Date:

Aug. 13, 2003

Test Result : Criterion A pass
Voltage

0.5kV

Polarity

Test
Line

1kV

+

-

+

-

L1

A

A

A

A

L2

A

A

A

A

GND

A

A

A

A

Signal/
Control Line

NR

NR

NR

NR

NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
NR: No requirement

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:33 of 33
Date: Oct. 08, 2005

8. SURGE TEST (POWER LINE)
8.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES
SURGE TEST
(System Mainframe)
SURGE TEST
(Impulse Network)
SURGE TEST
(Pulse Coupling Network)

MANUFACTURER
SCHAFFNER
SCHAFFNER
SCHAFFNER

MODEL # /
SERIAL #

DUE DATE OF CAL.
& CAL. CENTER

NSG 2050 /
199904-057SC

OCT. 2005
ETC

PNW 2050 /
256
CDN 131/133 /
520

OCT. 2005
ETC
OCT. 2005
ETC

8.2 TEST PROCEDURE
According to IEC/EN 61000-4-5:1995
8.3 TEST SET-UP
SURGE
GENERATOR

EUT

Auxiliary
Equipment

NOTE :
1. The EUT system was put on a wooden table with 0.8m height above ground reference plane.
2. For the actual test configuration, please refer to the photos of testing.

8.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.

8.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:34 of 34
Date: Oct. 08, 2005

TEST REPORT

8.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Test level
(2)
(3)
(4)
(5)
(6)
(7)

: Common mode : ±0.5kV, ±1kV, ±2kV
Differential mode : ±0.25kV, ±0.5kV, ±1kV
:5
: 0°, 90°, 180°, 270°
: Positive and Negative polarization
: 60 s
: 1.2/50 µs (open circuit)
: Criterion B

Number of Pulse
Phase
Polarity
Repetition
Waveform
Standard requirement

2. Performance criterion
(1) Criterion A
(2) Criterion B

: Normal performance during test
: Temporary degradation or loss of function
or performance which is self-recoverable
: Temporary degradation or loss of function
or performance which requires operator
intervention system reset

(3) Criterion C

8.7 SUMMARY OF TEST RESULT
Temperature:

24 °C

Humidity:

58% RH

Test Object:

EUT2

Tested By:

Tom Lin

Atmospheric Air Pressure:

101.2 kPa

Tested Date:

Aug. 13, 2003

Test Result : Criterion A pass
Mode

Common

Differential

Coupling
L + PE
N + PE

L+N

Voltage

Phase
0°

90°

180°

270°

+/-0.5kV

A

A

A

A

+/-1kV

A

A

A

A

+/-2kV

A

A

A

A

+/-0.25kV

A

A

A

A

+/-0.5kV

A

A

A

A

+/-1kV

A

A

A

A

NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:35 of 35
Date: Oct. 08, 2005

9. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST
9.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES

MANUFACTURER

EM INJECTION
CLAMP

FCC

POWER LINE CDN

FCC

POWER LINE CDN

FCC

POWER LINE CDN

FCC

SIGNAL LINE CDN

FCC

SIGNAL LINE CDN

FCC

SIGNAL LINE CDN

FCC

SIGNAL LINE CDN

FCC

POWER LINE CDN

FCC

SIGNAL
GENERATOR

MODEL # /
SERIAL #

FINAL
DUE DATE OF CAL.
TEST BE
& CAL. CENTER
USED

F-203I-23mm/
110

MAY 2006
ETC

FCC-801-M4-32A/
9808
FCC-801-M5-32A/
9812
FCC-801-M1-32A/
9820
FCC-801-T2/
9830
FCC-801-T4/
9831

MAY 2006
ETC
MAY 2006
ETC
MAY 2006
ETC
MAY 2006
ETC
MAY 2006
ETC

FCC-801-T6/
9832

MAY 2006
ETC

FCC-801-S9/
9843
FCC-801-M2-32A/
9840

MAY 2006
ETC
NOV. 2005
ETC

HP

8648A/
3636A02776

JUN. 2006
ETC

√

POWER AMPLIFIER

A.R.

150A100A/
19553

MAY 2006
ETC

√

DUAL DIRECTION
COULPER

A.R.

DC2600/
25893

SEP. 2006
ETC

√

POWER METER

BOONTON

4232A/
29001

MAY 2006
ETC

√

SIGNAL LINE CDN

FCC

FCC-801-S25/
9845

MAY 2006
ETC

POWER LINE CDN

FCC

T2

EM-TEST

COAXIAL CABLE

SUNCITY

COAXIAL CABLE

SUNCITY

COAXIAL CABLE

SUNCITY

FCC-801-M3-32A/
9874
ATT6/75/
1001-40
CABLE14/
#14-1M
CABLE05/
#5-5M
J400/
2M

MAY 2006
ETC
N/A
APR. 2006
SRT
APR. 2006
SRT
APR. 2006
SRT

√
√
√
√
√

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:36 of 36
Date: Oct. 08, 2005

9.2 TEST PROCEDURE
According to IEC/EN 61000-4-6:1996
9.3 TEST SET-UP
(1) For CDN injection :
EUT
Coaxial
SIGNAL

Cable

GENERATOR

Power

T2

CDN

Amplifier
Auxiliary Equipment

(2) For Clamp injection :
EUT

Monitoring Probe
Coaxial
SIGNAL
GENERATOR

Cable

Power
Amplifier

T2

Injection

Receiver

Clamp

Auxiliary Equipment
NOTE :
1. The EUT system was put on a wooden table with 0.1m height above ground.
2. For the actual test configuration, please refer to the photos of testing.
3. The distance between CDN(Clamp) and EUT was controlled between 0.1m and 0.3m.
4. The model no. of the CDN connected to EUT is FCC-801-M3-32A.

9.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.

9.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:37 of 37
Date: Oct. 08, 2005

TEST REPORT

9.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency
(2) Sweeping frequency
(3) Test level
(4) Modulation
(5) Dwell time for each frequency
(6) Standard requirement
2. Performance criterion
(1) Criterion A
(2) Criterion B

: 230 V/ 50 Hz, single phase
: 150 kHz – 80 MHz
: 3 V, the frequency step is 1%
: AM 80%, 1 kHz
: 3 sec
: Criterion A
: Normal performance during test
: Temporary degradation or loss of function
or performance which is self-recoverable
: Temporary degradation or loss of function
or performance which requires operator
intervention system reset

(3) Criterion C

9.7 SUMMARY OF TEST RESULT
Temperature:

24°C

Humidity:

51% RH

Test Object:

EUT1

Tested By:

Tom Lin

Test Result :

Criterion A pass

Tested Date:

Aug. 13, 2003

FREQUENCY

LEVEL

150kHz - 80MHz

3V

MODULATION
80% AM,

1 kHz

INJECTION
METHOD

TEST RESULT
(CRITERION)

M3

A

NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:38 of 38
Date: Oct. 08, 2005

TEST REPORT

Temperature:

24°C

Humidity:

51% RH

Test Object:

EUT2

Tested By:

Tom Lin

Test Result :

Criterion A pass

Tested Date:

Aug. 13, 2003

FREQUENCY

LEVEL

150kHz - 80MHz

3V

MODULATION
80% AM,

1 kHz

INJECTION
METHOD

TEST RESULT
(CRITERION)

M2

A

NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:39 of 39
Date: Oct. 08, 2005

TEST REPORT

10. POWER FREQUENCY MAGNETIC-FIELD TEST
10.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES
MAGNETIC FIELD
TESTER
MAGNETIC FIELD
COIL

HAEFELY

MAGNETIC FIELD
METER

F.W.BELL

MANUFACTURER

HAEFELY

MODEL # /
SERIAL #
MAG 100.1/
080.015-04
MAG 100.1/
080.015-04

DUE DATE OF CAL.
& CAL. CENTER
JAN. 2006
SRT
JAN. 2006
SRT

4080/
19990416

MAR. 2006
ITRI

10.2 TEST PROCEDURE
According to IEC/EN 61000-4-8:1993

10.3 TEST SET-UP
Magnetic Coil

EUT
Test Generator

Frequency Converter

NOTE :
1. The EUT system was put on a wooden table with 0.8m height above ground.
2. For the actual test configuration, please refer to the photos of testing
3. 1A/m = 12.56mG, 3A/m = 37.68mG, 10A/m = 125.6mG,

10.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:40 of 40
Date: Oct. 08, 2005

10.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.

10.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Test axis
(2) Test time
(3) Field strength
(4) Standard requirement

: X, Y and Z axes
: 5 min / each axis
: 3 A/m
: Criterion A

2. Performance criterion
(1) Criterion A
(2) Criterion B

: Normal performance during test
: Temporary degradation or loss of function
or performance which is self-recoverable
: Temporary degradation or loss of function
or performance which requires operator
intervention system reset

(3) Criterion C

10.7 SUMMARY OF TEST RESULT
Temperature:

24°C

Humidity:

54%H

Test Object:

EUT1+EUT2

Tested By:

Tom Lin

Frequency of Magnetic Field:

■50Hz, □60Hz

Tested Date:

Aug. 14, 2003

Test Result : Criterion A pass
ORIENTATION

FIELD
STRENGTH

TEST RESULT
(CRITERION)

X

3 A/m

A

Y

3 A/m

A

Z

3 A/m

A

NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:41 of 41
Date: Oct. 08, 2005

11. VOLTAGE DIPS, INTERRUPTS, VARIATIONS TEST
11.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES
INTERFERENCE
SIMULATOR

MANUFACTURER
HAEFELY

MODEL # /
SERIAL #
PLINE 1610/
083-732-05

DUE DATE OF CAL.
& CAL. CENTER
APR. 2006
ETC

11.2 TEST PROCEDURE
According to IEC/EN 61000-4-11:1994

11.3 TEST SET-UP
Frequency

Interference

Converter

Simulator

Power cable

EUT

NOTE :
1. The EUT system was put on a wooden table with 0.8m height above ground.
2. For the actual test configuration, please refer to the photos of testing.

11.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.

11.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.

Auxiliary Equipment

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:42 of 42
Date: Oct. 08, 2005

11.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency
(2) Test level
(3)
(4)
(5)
(6)

Phase
Test duration
Time between test
Standard requirement

2. Performance criterion
(1) Criterion A
(2) Criterion B

: 230V/50Hz, single phase
: Dip depth 95%, 0.5 period
30%, 25 period
Interrupt 95%, 250 period
: 0°, 180°
: 2min each phase
: 10 sec
: Dip 95%
: Criterion B;
Dip 30%
: Criterion C;
Interrupt > 95%: Criterion C
: Normal performance during test
: Temporary degradation or loss of function
or performance which is self-recoverable.
: Temporary degradation or loss of function
or performance which requires operator
intervention system reset.

(3) Criterion C

11.7 SUMMARY OF TEST RESULT
Temperature:

24°C

Humidity:

54% RH

Test Object:

EUT2

Tested By:

Tom Lin

Tested Date:

Aug. 14, 2003

AC
POWER

230V/50Hz

DIP
DEPTH

INTERVAL DIP TIME

TEST TIME

95%

10 sec

0.5 period

2 min

30%

10 sec

25 period

2 min

95%
(interrupt)

10 sec

250 period

2 min

PHASE
0°
180°
0°
180°
0°
180°

TEST
RESULT
(Criterion)
A
A
A
A
B
B

NOTE:
1. The power voltage range: 100V to 240V, and the range 140V is 140% of the lowest voltage.
2. Description of test observation:
A: There was no change compared with initial operation during the test.
B: EUT delayed in data copy during testing.

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

12. PHOTOS OF TESTING
- Conducted test (EUT1)

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:43 of 43
Date: Oct. 08, 2005

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

- Conducted test (EUT2)

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:44 of 44
Date: Oct. 08, 2005

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

- Radiated test (EUT1+EUT2)

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:45 of 45
Date: Oct. 08, 2005

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

- Harmonics test (EUT2)

- Voltage fluctuations test (EUT2)

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:46 of 46
Date: Oct. 08, 2005

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:47 of 47
Date: Oct. 08, 2005

- Electrostatic discharge immunity test (EUT1+EUT2)

- Electrical fast transient / burst immunity test (EUT1+EUT2)

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

- Radiated immunity test (EUT1+EUT2)

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:48 of 48
Date: Oct. 08, 2005

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

-Surge test (power line) (EUT2)

- Inducted RF fields (conducted susceptibility) test (EUT1)

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:49 of 49
Date: Oct. 08, 2005

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

- Inducted RF fields (conducted susceptibility) test (EUT2)

- Power frequency magnetic-field test (EUT1+EUT2)

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:50 of 50
Date: Oct. 08, 2005

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

- Voltage dips, interrupts, variations test (EUT2)

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:51 of 51
Date: Oct. 08, 2005

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.

TEST REPORT

Reference No.:A05100404
Report No.:EMCA03051901-02
Page:52 of 52
Date: Oct. 08, 2005

13. TERMS OF ABRIVATION
AV.

Average detection

AZ(°)

Turn table azimuth

Correct.

Correction

EL(m)

Antenna height (meter)

EUT

Equipment Under Test

Horiz.

Horizontal direction

LISN

Line Impedance Stabilization Network

NSA

Normalized Site Attenuation

Q.P.

Quasi-peak detection

SRT Lab

Spectrum Research & Testing Laboratory, Inc.

Vert.

Vertical direction



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Create Date                     : 2005:10:11 09:40:57Z
Modify Date                     : 2009:01:15 10:54:51+08:00
Metadata Date                   : 2009:01:15 10:54:51+08:00
Format                          : application/pdf
Document ID                     : uuid:91fe6070-0f16-4877-bfd2-73e00be145ec
Instance ID                     : uuid:bd2a8f6c-545e-401a-b8c6-fb628953cfe7
Page Count                      : 52
EXIF Metadata provided by EXIF.tools

Navigation menu