Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:2 of 2
Date: Oct. 08, 2005
Table of Contents
1. DOCUMENT POLICY AND TEST STATEMENT ................................................5
1.1 DOCUMENT POLICY ........................................................................................ 5
1.2 TEST STATEMENT............................................................................................ 5
2. DESCRIPTION OF EUT AND TEST MODE.......................................................6
2.1 GENERAL DESCRIPTION OF EUT .................................................................. 6
2.2 DESCRIPTION OF EUT INTERNAL DEVICE.................................................... 6
2.3 DESCRIPTION OF TEST MODE ....................................................................... 7
3. DESCRIPTION OF APPLIED STANDARDS ...................................................... 7
4. EMISSION TEST................................................................................................8
4.1 CONDUCTED EMISSION TEST FOR POWER PORT ...................................... 8
4.1.1 CONDUCTED EMISSION LIMIT........................................................................ 8
4.1.2 TEST EQUIPMENT............................................................................................ 8
4.1.3 TEST SETUP..................................................................................................... 9
4.1.4 TEST PROCEDURE .......................................................................................... 9
4.1.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 10
4.1.6 EUT OPERATING CONDITION ....................................................................... 10
4.1.7 TEST RESULT ................................................................................................. 11
4.2 RADIATED EMISSION TEST........................................................................... 13
4.2.1 RADIATED EMISSION LIMIT........................................................................... 13
4.2.2 TEST EQUIPMENT.......................................................................................... 13
4.2.3 TEST SET-UP.................................................................................................. 14
4.2.4 TEST PROCEDURE ........................................................................................ 14
4.2.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 15
4.2.6 EUT OPERATING CONDITION ....................................................................... 15
4.2.7 TEST RESULT ................................................................................................. 16
4.3 CURRENT HARMONICS TEST....................................................................... 17
4.3.2 TEST EQUIPMENT.......................................................................................... 18
4.3.3 TEST SETUP................................................................................................... 18
4.3.4 TEST PROCEDURE ........................................................................................ 18
4.3.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 18
4.3.6 EUT OPERATING CONDITION ....................................................................... 18
4.3.7 TEST RESULT ................................................................................................. 19
4.4 VOLTAGE FLUCTUATIONS .......................................................................... 20
4.4.1 LIMIT ............................................................................................................. 20
4.4.2 TEST EQUIPMENT.......................................................................................... 20
4.4.3 TEST PROCEDURE ........................................................................................ 20
4.4.4 TEST SETUP................................................................................................... 21
4.4.5 DESCRIPTION OF SUPPORT UNIT ............................................................... 21
4.4.6 EUT OPERATING CONDITION ....................................................................... 21
4.4.7 TEST RESULT ................................................................................................. 22
5. ELECTROSTATIC DISCHARGE IMMUNITY TEST ........................................... 23
5.1 TEST EQUIPMENT .......................................................................................... 23
5.2 TEST PROCEDURE ........................................................................................ 23
5.3 TEST SET-UP .................................................................................................. 24
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:3 of 3
Date: Oct. 08, 2005
5.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 25
5.5 EUT OPERATING CONDITION ....................................................................... 25
5.6 TEST CONDITION AND PERFORMANCE CRITERION................................. 25
5.7 SUMMARY OF TEST RESULT........................................................................ 26
6. RADIATED IMMUNITY TEST............................................................................. 27
6.1 TEST EQUIPMENT .......................................................................................... 27
6.2 TEST PROCEDURE ........................................................................................ 27
6.3 TEST SETUP ................................................................................................... 28
6.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 29
6.5 EUT OPERATING CONDITION ....................................................................... 29
6.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 29
6.7 TEST RESULT ................................................................................................. 29
7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST .......................... 30
7.1 TEST EQUIPMENT .......................................................................................... 30
7.2 TEST PROCEDURE ........................................................................................ 30
7.3 TEST SET-UP .................................................................................................. 31
7.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 31
7.5 EUT OPERATING CONDITION ....................................................................... 31
7.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 32
7.7 SUMMARY OF TEST RESULT........................................................................ 32
8. SURGE TEST (POWER LINE)........................................................................... 33
8.1 TEST EQUIPMENT .......................................................................................... 33
8.2 TEST PROCEDURE ........................................................................................ 33
8.3 TEST SET-UP .................................................................................................. 33
8.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 33
8.5 EUT OPERATING CONDITION ....................................................................... 33
8.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 34
8.7 SUMMARY OF TEST RESULT........................................................................ 34
9. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST...................... 35
9.1 TEST EQUIPMENT .......................................................................................... 35
9.2 TEST PROCEDURE ........................................................................................ 36
9.3 TEST SET-UP .................................................................................................. 36
9.4 DESCRIPTION OF SUPPORT UNIT ............................................................... 36
9.5 EUT OPERATING CONDITION ....................................................................... 36
9.6 TEST CONDITION / PERFORMANCE CRITERIA .......................................... 37
9.7 SUMMARY OF TEST RESULT........................................................................ 37
10. POWER FREQUENCY MAGNETIC-FIELD TEST ........................................... 39
10.1 TEST EQUIPMENT ........................................................................................ 39
10.2 TEST PROCEDURE ...................................................................................... 39
10.3 TEST SET-UP ................................................................................................ 39
10.4 DESCRIPTION OF SUPPORT UNIT ............................................................. 39
10.5 EUT OPERATING CONDITION ..................................................................... 40
10.6 TEST CONDITION / PERFORMANCE CRITERIA ........................................ 40
10.7 SUMMARY OF TEST RESULT ...................................................................... 40
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:4 of 4
Date: Oct. 08, 2005
11. VOLTAGE DIPS, INTERRUPTS, VARIATIONS TEST...................................... 41
11.1 TEST EQUIPMENT ........................................................................................ 41
11.2 TEST PROCEDURE....................................................................................... 41
11.3 TEST SET-UP ................................................................................................ 41
11.4 DESCRIPTION OF SUPPORT UNIT.............................................................. 41
11.5 EUT OPERATING CONDITION ..................................................................... 41
11.6 TEST CONDITION / PERFORMANCE CRITERIA......................................... 42
11.7 SUMMARY OF TEST RESULT ...................................................................... 42
12. PHOTOS OF TESTING.................................................................................... 43
13. TERMS OF ABRIVATION................................................................................. 52
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:5 of 5
Date: Oct. 08, 2005
1. DOCUMENT POLICY AND TEST STATEMENT
1.1 DOCUMENT POLICY
- The report shall not be reproduced except in full, without the written approval of
SRT Lab, Inc.
- The report must not be used by the applicant to claim that the product is endorsed
by NVLAP, TÜV, NEMKO and SRT.
- The NVLAP logo applies only to the applicable standards specified in this report.
1.2 TEST STATEMENT
- The test results in the report apply only to the unit tested by SRT Lab.
- There was no deviation from the requirements of test standards during the test.
- AC power source, 230 VAC/50 Hz, was used during the test.
- The EN 61000-3-2:1995+A1:1998+A2:1998(Harmonic test) and EN 61000-3-3:
1995+A1:1998(Flicker test) are not included in the scope of NVLAP logo usage.
- The EN 61000-3-2:1995+A1:1998+A2:1998(Harmonic test) and EN 61000-3-3:
1995+A1:1998(Flicker test) are included in the scope of TÜV, NEMKO and SRT
logo usage.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:6 of 6
Date: Oct. 08, 2005
2. DESCRIPTION OF EUT AND TEST MODE
2.1 GENERAL DESCRIPTION OF EUT
PRODUCT SATA CardBus
MODEL NO. PC-113,PC-113R,PC-112,PC-112R,ST-109R
POWER SUPPLY N/A
CABLE N/A
NOTE:
The EUT consisted of one SATA card (presented in this report as EUT1) and one HDD (presented in this
report as EUT2).
For more detailed information, please refer to the EUT’s specification or user’s manual provided by
manufacturer.
2.2 DESCRIPTION OF EUT INTERNAL DEVICE
DEVICE BRAND / MAKER MODEL # REMARK
N/A
NOTE :
1. The highest clock of EUT1 and EUT2 are 25MHz.
2. Frequency range to be measured.
Radiated emission is 30 MHz to 1 GHz.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:7 of 7
Date: Oct. 08, 2005
2.3 DESCRIPTION OF TEST MODE
The EUT was tested for emission measurement under the following situations:
For certain test items, the test object is either EUT1 or EUT2. When either one
represented the test object, the other was regarded as one of the support units.
3. DESCRIPTION OF APPLIED STANDARDS
The EUT is a kind of ITE interface device and according to the specifications provided
by the applicant, it must comply with the requirements of the following standards:
EN 55022:1998, Class B EN 55024:1998
EN 61000-3-2:1995+ A1:1998+A2:1998 - IEC 61000-4-2:1995+A1:1998
EN 61000-3-3:1995+A1:1998 - IEC 61000-4-3:1995+A1:1998
- IEC 61000-4-4:1995
- IEC 61000-4-5:1995
- IEC 61000-4-6:1996
- IEC 61000-4-8:1993
- IEC 61000-4-11:1994
However, the standards of EN 61000-3-2, EN 61000-3-3, IEC 61000-4-5 and IEC
61000-4-11 were not measured for EUT1 for the power source of EUT1 is DC from PC.
All tests have been performed and recorded as per the required standards.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:8 of 8
Date: Oct. 08, 2005
4. EMISSION TEST
4.1 CONDUCTED EMISSION TEST FOR POWER PORT
4.1.1 CONDUCTED EMISSION LIMIT
Class A (dBµV) Class B (dBµV)
Frequency (MHz) Quasi-peak Average Quasi-peak Average
0.15 - 0.5 79 66 66 - 56 56 - 46
0.50 - 5.0 73 60 56 46
5.0 - 30.0 73 60 60 50
NOTE:
1. The lower limit shall apply at the transition frequencies.
2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.
4.1.2 TEST EQUIPMENT
The following test equipment was used for the test:
EQUIPMENT/
FACILITIES SPECIFICATIONS MANUFACTURER MODEL#/
SERIAL#
DUE DATE OF CAL.
& CAL. CENTER
EMI TEST
RECEIVER
9 kHz TO
30 MHz
ROHDE &
SCHWARZ
ESHS30/
826003/008
AUG. 2006
R&S
LISN (for EUT) 50 µH, 50 ohm SOLAR
ELECTRONICS
8012-50-R-24-BNC
/ 924839
JUN. 2006
ETC
LISN
(for Peripheral) 50µH, 50 ohm SOLAR
ELECTRONICS
9252-50-R-24-BNC
/ 951318
JUN. 2006
ETC
50 ohm
TERMINATOR 50 ohm HP 11593A/
2
MAY 2006
ETC
COAXIAL
CABLE 3m SUNCITY J400/
3M
JUL. 2006
SRT
ISOLATION
TRANSFORMER N/A APC AFC-11015/
F102040016 N/A
FILTER 2 LINE, 30A FIL.COIL FC-943/
771 N/A
GROUND PLANE 2.3M (H) x
2.4M (W) SRT N/A APR. 2006
SRT
GROUND PLANE 2.4M (H) x
2.4M (W) SRT N/A APR. 2006
SRT
NOTE: The calibration interval of the above test equipment is one year and the calibrations are
traceable to NML/ROC and NIST/USA.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:9 of 9
Date: Oct. 08, 2005
4.1.3 TEST SETUP
NOTE:
1. The EUT was put on a wooden table with 0.8m height above ground plane, and 0.4m away from
reference ground plane (> 2mx2m).
2. For the actual test configuration, please refer to the photos of testing.
3. The serial no. of the LISN connected to EUT is 951318.
4. The serial no. of the LISN connected to support units is 924839.
4.1.4 TEST PROCEDURE
The EUT was tested according to the requirement of EN 55022:1998. The frequency
spectrum from 0.15 MHz to 30 MHz was investigated. The LISN used was 50/50µH
as specified. All readings were quasi-peak and average values with 10 kHz resolution
bandwidth of the test receiver.The EUT system was operated in all typical methods by
users. Both lines of the power mains of EUT were measured and the cables connected
to EUT and support units were moved to find the maximum emission levels for each
frequency.
First, Find the margin or higher points at least 6 points by software, then use manual to
find the maximum data. The procedure is referred on the test procedure of SRT LAB.
Isolation
Transformer Filter LISN
LISN
EUT
Support Units
EMI TEST
Receiver
To Utility
Power
Coaxial Cable
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:10 of 10
Date: Oct. 08, 2005
4.1.5 DESCRIPTION OF SUPPORT UNIT
The EUT was configured by the requirement of EN 55022:1998. All interface ports were
connected to the appropriate support units via specific cables. The support units and
cables are listed below.
NO DEVICE BRAND MODEL # CABLE
1 MONITOR SAMSUNG PG17IS 1.5m unshielded power cord
1.2m shielded data cable
2 PRINTER EPSON STYLUS C20SX
1.5m unshielded power cord
1.2m shielded data cable
3 MODEM ACEEX DM-1414 1.5m unshielded DC power cable
1.2m shielded data cable
4 MOUSE LOGITECH MS-34 1.5m unshielded data cable
5 HDD HITACHI DK23CA-10 N/A
6 NOTEBOOK IBM 560Z 1.5m unshielded power cord
7 ADAPTOR WELLAND PA-213-50 1.5m unshielded power cord
NOTE : For the actual test configuration, please refer to the photos of testing.
4.1.6 EUT OPERATING CONDITION
1. Under Windows 98 ran “EMI TEST” and “Ping.bat” programs and PC sent "H" pattern
or accessed the following peripherals directly or via EUT:
- Color Monitor
- RS232
- Keyboard
- Mouse
- Printer
- FDD
- HDD
2. Under Windows XP run “XCOPY” program.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:11 of 11
Date: Oct. 08, 2005
4.1.7 TEST RESULT
Temperature: 25 °C Humidity: 52 %RH
Frequency Range: 0.15 – 30 MHz Test Object: EUT2
Receiver Detector: Q.P. and AV. Tested By: Tom Lin
Tested Date: Aug. 25, 2003
Power Line Measured : Line
Reading Value
(dBµV)
Emission Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Freq.
(MHz)
Correct.
Factor
(dB) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV.
0.205 0.20 48.8 45.6 49.0 45.8 63.4 53.4 -14.4 -7.6
0.509 0.20 45.8 45.3 46.0 45.5 56.0 46.0 -10.0 -0.5
0.607 0.20 40.8 39.7 41.0 39.9 56.0 46.0 -15.0 -6.1
2.029 0.20 43.1 42.7 43.3 42.9 56.0 46.0 -12.7 -3.1
3.654 0.26 44.9 41.2 45.2 41.5 56.0 46.0 -10.8 -4.5
5.884 0.33 48.5 46.2 48.8 46.5 60.0 50.0 -11.2 -3.5
Power Line Measured : Neutral
Reading Value
(dBµV)
Emission Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Freq.
(MHz)
Correct.
Factor
(dB) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV.
0.205 0.20 46.0 40.0 46.2 40.2 63.4 53.4 -17.2 -13.2
0.408 0.20 41.3 38.5 41.5 38.7 57.7 47.7 -16.2 -9.0
1.322 0.20 38.7 36.9 38.9 37.1 56.0 46.0 -17.1 -8.9
2.951 0.20 38.9 37.4 39.1 37.6 56.0 46.0 -16.9 -8.4
5.904 0.33 44.0 41.2 44.3 41.5 60.0 50.0 -15.7 -8.5
9.974 0.40 37.7 31.2 38.1 31.6 60.0 50.0 -21.9 -18.4
NOTE :
1. Measurement uncertainty is +/-2dB
2. Emission level = Reading value + Correction factor
3. Correction Factor = Cable loss + Insertion loss of LISN
4. Margin value = Emission level - Limit
5. The emission of other frequencies were very low against the limit.
6. "-": The Quasi-peak reading value also meets average limit and measurement with the average
detector is unnecessary.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:12 of 12
Date: Oct. 08, 2005
Temperature: 25 °C Humidity: 52 %RH
Frequency Range: 0.15 – 30 MHz Test Object: EUT1
Receiver Detector: Q.P. and AV. Tested By: Tom Lin
Tested Date: Aug. 25, 2003
Power Line Measured : Line
Reading Value
(dBµV)
Emission Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Freq.
(MHz)
Correct.
Factor
(dB) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV.
0.162 0.20 53.6 52.5 53.8 52.7 65.4 55.4 -11.6 -2.7
0.420 0.20 40.1 34.8 40.3 35.0 57.4 47.4 -17.1 -12.4
0.740 0.20 39.2 28.9 39.4 29.1 56.0 46.0 -16.6 -16.9
2.623 0.20 37.4 25.4 37.6 25.6 56.0 46.0 -18.4 -20.4
8.529 0.37 42.0 31.1 42.4 31.5 60.0 50.0 -17.6 -18.5
19.236 0.58 42.9 36.4 43.5 37.0 60.0 50.0 -16.5 -13.0
Power Line Measured : Neutral
Reading Value
(dBµV)
Emission Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Freq.
(MHz)
Correct.
Factor
(dB) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV.
0.170 0.20 52.0 39.4 52.2 39.6 65.0 55.0 -12.8 -15.4
0.759 0.20 40.8 27.8 41.0 28.0 56.0 46.0 -15.0 -18.0
1.232 0.20 40.8 28.9 41.0 29.1 56.0 46.0 -15.0 -16.9
3.060 0.20 44.6 22.5 44.8 22.7 56.0 46.0 -11.2 -23.3
7.642 0.36 42.6 28.1 43.0 28.5 60.0 50.0 -17.0 -21.5
8.130 0.37 41.3 30.1 41.7 30.5 60.0 50.0 -18.3 -19.5
NOTE :
1. Measurement uncertainty is +/-2dB
2. Emission level = Reading value + Correction factor
3. Correction Factor = Cable loss + Insertion loss of LISN
4. Margin value = Emission level - Limit
5. The emission of other frequencies were very low against the limit.
6. "-": The Quasi-peak reading value also meets average limit and measurement with the average
detector is unnecessary.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:13 of 13
Date: Oct. 08, 2005
4.2 RADIATED EMISSION TEST
4.2.1 RADIATED EMISSION LIMIT
EN 55022:1998 limits of radiated emission measurement for frequency below 1000
MHz
Class A (at 10m) Class B (at 10m)
FREQUENCY (MHz) dBµV/m dBµV/m
30 – 230 40 30
230 - 1000 47 37
NOTE:
1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBµV/m) = 20 log Emission level (µV/m).
4.2.2 TEST EQUIPMENT
The following test equipment was used during the radiated emission test:
EQUIPMENT/
FACILITIES SPECIFICATIONS MANUFACTURER MODEL#/
SERIAL#
DUE DATE OF CAL. &
CAL. CENTER
EMI TEST
RECEIVER
20 MHz TO
1 GHz
ROHDE &
SCHWARZ
ESVS30/
841977/003
AUG. 2006
R&S
BI-LOG
ANTENNA
25 MHz TO
2 GHz EMCO 3142/
9701-1124
APR. 2006
SRT
OATS 3 – 10 M
MEASUREMENT SRT SRT-1 APR. 2006
SRT
COAXIAL
CABLE 25M SUNCITY J400/
25M
AUG. 2006
SRT
FILTER 2 LINE, 30A FIL.COIL FC-943/
869 N/A
FREQUENCY
CONVERTER N/A APC AFC-2KBB/
F100030031
AUG. 2006
SRT
NOTE:
1. The calibration interval of the above test equipment is one year and the calibrations are traceable to
NML/ROC and NIST/USA.
2. The Open Area Test Site (SRT-1) is registered by FCC with No. 90957 and VCCI with No. R-1081.
3. The Open Area Test Site (SRT-2) is registered by FCC with No. 98458 and VCCI with No. R-1168.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:14 of 14
Date: Oct. 08, 2005
4.2.3 TEST SET-UP
NOTE:
1. The EUT system was put on a wooden table with 0.8m heights above a ground plane.
2. For the actual test configuration, please refer to the photos of testing.
4.2.4 TEST PROCEDURE
The EUT was tested according to the requirement of EN 55022:1998. The
measurements were made at an open area test site with 10 meter measurement
distance. The frequency spectrum measured from 30 MHz to 1 GHz. All readings were
quasi-peak values with 120 kHz resolution bandwidth of the test receiver. The EUT
system was operated in all typical methods by users. The cables connected to EUT and
support units were moved to find the maximum emission levels for each frequency.
First, Find the margin or higher points at least 6 points by software, then use manual to
find the maximum data. The procedure is referred on the test procedure of SRT LAB.
EMI Receiver
Filter To Utility
Power
EUT
Ground Plane
3/10m
0.8 m
Coaxial
Cable
Turn Table
1m – 4m
Power Cable
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:15 of 15
Date: Oct. 08, 2005
4.2.5 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
4.2.6 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:16 of 16
Date: Oct. 08, 2005
4.2.7 TEST RESULT
Temperature: 25 °C Humidity: 50 %RH
Frequency Range: 30 – 1000 MHz Measured Distance: 10m
Receiver Detector: Q.P. Tested Object: EUT1+EUT2
Tested By: Tom Lin Tested Date: Aug. 25, 2003
Antenna Polarization: Horizontal
Frequency
(MHz)
Cable
Loss
(dB)
Antenna
Factor
(dB/m)
Reading
Data
(dBµV)
Emission
Level
(dBµV/m)
Limit
(dBµV/m)
Margin
(dB) AZ(°) EL(m)
75.9600 1.09 7.10 18.5 26.7 30.0 -3.3 254 4
149.9900 1.48 8.54 15.2 25.2 30.0 -4.8 291 4
299.9850 2.06 14.42 13.8 30.3 37.0 -6.7 98 4
449.9770 2.51 16.89 12.1 31.5 37.0 -5.5 125 4
601.4750 2.73 20.81 9.3 32.8 37.0 -4.2 61 4
749.9555 2.98 22.78 11.0 36.8 37.0 -0.2 88 4
Antenna Polarization: Vertical
Frequency
(MHz)
Cable
Loss
(dB)
Antenna
Factor
(dB/m)
Reading
Data
(dBµV)
Emission
Level
(dBµV/m)
Limit
(dBµV/m)
Margin
(dB) AZ(°) EL(m)
99.4152 1.12 8.34 17.5 27.0 30.0 -3.0 41 1
118.5284 1.32 7.54 13.8 22.7 30.0 -7.3 60 1
149.9900 1.48 8.54 18.2 28.2 30.0 -1.8 94 1
200.4970 1.63 9.90 10.5 22.0 30.0 -8.0 101 1
449.9773 2.51 16.89 13.4 32.8 37.0 -4.2 117 1
749.9623 2.98 22.78 8.9 34.7 37.0 -2.3 52 1
NOTE :
1. Measurement uncertainty is +/-4dB.
2. "*": Measurement does not apply for this frequency.
3. Emissiom Level = Reading Value + Ant. Factor + Cable Loss.
4. The field strength of other emission frequencies were very low against the limit.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:17 of 17
Date: Oct. 08, 2005
4.3 CURRENT HARMONICS TEST
4.3.1 LIMIT
For Class A Equipment
EVEN HARMONICS ODD HARMONICS
HARMONICS
ORDER LIMIT (Amp.) HARMONICS
ORDER LIMIT (Amp.)
2 1.08 3 2.30
4 0.43 5 1.14
6 0.30 7 0.77
8 < n < 40 0.23 x 8 / n 9 0.40
11 0.33
13 0.21
15 < n < 39 0.15 x 8 / n
For Class D Equipment
Harmonics Order
n
Max. permissible harmonics
current per watt (mA/W)
Max. permissible harmonics
current (A)
Odd Harmonics only
3 3.4 2.30
5 1.9 1.14
7 1.0 0.77
9 0.5 0.40
11 0.35 0.33
13 0.30 0.21
15 n 39 3.85 / n 0.15 x 15 / n
NOTE:
1. Class A and Class D are judged by test equipment automatically as per Section 5 of
EN 61000-3-2:1995
2. The above limits for Class D equipment are for all applications having an active input power > 75 W.
No limits apply for equipment with an active input power up to and including 75 W.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:18 of 18
Date: Oct. 08, 2005
4.3.2 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
DUE DATE OF CAL.
& CAL. CENTER
MAIN UNIT HP 6842A/
3734A00212
MAR. 2006
AGILENT
NOTE: The calibration interval of the above test equipment is one year and the calibrations are
traceable to NML/ROC and NIST/USA.
4.3.3 TEST SETUP
NOTE :
1. The EUT system was put on a wooden table with 0.8m high.
2. For the actual test configuration, please refer to the photos of testing.
4.3.4 TEST PROCEDURE
According to EN61000-3-2:1995+A1:1998+A2:1998
4.3.5 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
4.3.6 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
Auxiliary
Equipment
EUT
Harmonics/
Flicker tester
To utility power
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:19 of 19
Date: Oct. 08, 2005
4.3.7 TEST RESULT
Temperature: 26 °C Humidity: 46% RH
Fundamental Current:
Voltage:
0.033A
225.6Vrms
Max. Power
Consumption:
4.5W
Power Factor: 0.308 Tested Object: EUT2
Tested By: Tom Lin Test Date: Aug. 25, 2003
Maximum Reading Data:
Odd
Harm. Order Reading Data (A) Limit (A) Test Result
3 0.0196 0.9 PASS
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:20 of 20
Date: Oct. 08, 2005
4.4 VOLTAGE FLUCTUATIONS
4.4.1 LIMIT
Short-team flicker (Pst) : 1.0
Long-term flicker (Plt) : 0.65
Relative steady-state voltage change (Dc) : 3%
Relative voltage change characteristic (D (t) ) > 3% ; (TD(t)) : 200 ms
Maximum relative voltage change (Dmax) : 4%
TEST ITEM LIMIT NOTE
Pst 1.0 Pst means short-term flicker indicator.
Plt 0.65 Plt means long-term flicker indicator.
TD(t) (ms) 200 TD(t) means maximum time that D (t) exceeds 3 %.
Dmax (%) 4% Dmax means maximum relative voltage change.
Dc (%) 3% Dc means relative steady-state voltage change
4.4.2 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
DUE DATE OF CAL.
& CAL. CENTER
MAIN UNIT HP 6842A/
3734A00212
MAR. 2006
AGILENT
NOTE: The calibration interval of the above test equipment is one year and the calibrations are
traceable to NML/ROC and NIST/USA.
4.4.3 TEST PROCEDURE
According to EN 61000-3-3:1995+A1:1998
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:21 of 21
Date: Oct. 08, 2005
4.4.4 TEST SETUP
NOTE : 1. The EUT system was put on a wooden table with 0.8m high.
2. For the actual test configuration, please refer to the photos of testing.
4.4.5 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
4.4.6 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
Auxiliary
Equipment
EUT
Harmonics/
Flicker tester
To utility power
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:22 of 22
Date: Oct. 08, 2005
4.4.7 TEST RESULT
Temperature: 26 °C Humidity: 46% RH
Input Voltage:
Ampere:
225.6Vrms
0.1Arms
Observation
Period:
1Hr
Power Factor: 0.300 Tested Object: EUT2
Tested By: Tom Lin Test Date: Aug. 25, 2003
Test Result:
TEST PARAMETER MEASUREMENT
VALUE LIMIT TEST RESULT
Pst 0.07 1.0 PASS
Plt 0.07 0.65 PASS
TD(t) (ms) 0 200 PASS
Dmax (%) 0% 4% PASS
Dc (%) 0% 3% PASS
NOTE:
1. Pst means short-term flicker indicator.
2. Plt means long-term flicker indicator.
3. TD(t) means maximum time that D(t) exceeds 3 %.
4. Dmax means maximum relative voltage change.
5. Dc means relative steady-state voltage change.
6. N/A: Not applicable.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:23 of 23
Date: Oct. 08, 2005
5. ELECTROSTATIC DISCHARGE IMMUNITY TEST
5.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL #
DUE DATE OF CAL.
& CAL. CENTER
ESD SIMULATOR NOISEKEN ESS-100L(A)/TC-815P/
8099C02238/7099C02
NOV. 2005
ETC
HCP (1.6M x 0.8M) SRT WITH TWO 470k OHM
CABLE
APR. 2006
SRT
VCP (0.5M x 0.5M) SRT WITH TWO 470k OHM
CABLE
APR. 2006
SRT
GROUND PLANE
(3.4M x 2.4M) SRT N/A N/A
NOTE: The calibration interval of the above test equipment is one year and the calibrations are
traceable to NML/ROC and NIST/USA.
5.2 TEST PROCEDURE
According to IEC/EN 61000-4-2:1995+A1:1998
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:24 of 24
Date: Oct. 08, 2005
5.3 TEST SET-UP
NOTE :
1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT.
2. For the actual test configuration, please refer to the photos of testing.
3. A distance of 1m minimum was provided between EUT and walls / other metallic structure.
Insulating Support
ESD Gun
Return
Cable
EUT System
Vertical Coupling Plane
Ground Reference Plane
Horizontal Coupling
Plane
Wooden Table
470k
470k
10 cm
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:25 of 25
Date: Oct. 08, 2005
5.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
5.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
5.6 TEST CONDITION AND PERFORMANCE CRITERION
1. Test condition
(1) R-C Network :330 , 150 pF
(2) Test level: Air Discharge :±2kV, ±4kV, ±8kV
Contact discharge :±2kV, ±4kV
HCP discharge : ±2kV, ±4kV
VCP discharge : ±2kV, ±4kV
(3) Discharge mode :
Single discharge
(4) Discharge period :
at least 1 s
(5) Discharge polarity :
Positive and Negative
(6) Number of discharge :
Minimum 50 times at each test point of contact
discharge and at least 200 times of discharge to
EUT in total. Minium 10 times at each test area
of air discharge selected.
2. Standard requirement :
Criterion B
3. Performance criterion
(1) Criterion A :
Normal performance during test
(2) Criterion B :
Temporary degradation or loss of function or
performance which is self-recoverable
(3) Criterion C :
Temporary degradation or loss of function or
performance which requires operator
intervention system reset
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:26 of 26
Date: Oct. 08, 2005
5.7 SUMMARY OF TEST RESULT
Temperature: 20 °C Humidity: 48% RH
Test Object: EUT1+EUT2 Tested By: Tom Lin
Atmospheric Air Pressure: 101.2 kPa Tested Date: Aug. 25, 2003
Test Result: Criterion B pass
COUPLING MODE & TEST OBSERVATION
SEVERITY
LEVEL AIR
DISCHARGE CONTACT
DISCHARGE HCP VCP
±2kV A A A A
±4kV A B A A
±8kV B NR NR NR
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
B: The function of data copy was delayed during testing.
NR: No requirement
Description of test points:
1. Metallic part of SATA port on EUT1 & EUT2.
2. Screw of EUT2.
3. Case of EUT2.
4. HCP.
5. VCP.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:27 of 27
Date: Oct. 08, 2005
6. RADIATED IMMUNITY TEST
6.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL #
DUE DATE OF CAL.
& CAL. CENTER
SIGNAL
GENERATOR HP 8648A/
3636A022776
JUN. 2006
ETC
ANTENNA SCHAFFNER
CHASE
CBL6111/
1188
AUG. 2006
SRT
FIELD SENSOR AMPLIFIER
RESEARCH
FP2000/
28499
DEC. 2005
ETC
POWER
AMPLIFIER
AMPLIFIER
RESEARCH
100W1000M1/
19509
JUN. 2006
ETC
ANECHOIC
CHAMBER SRT A05/
SRT005
SEP. 2006
SRT
V/M MONITOR A.R. FM2000/
15970 N/A
MONITOR SHIN SI-609/
905130 N/A
CCD TOPVIEW N/A/
95113762 N/A
ABSORBER ETS N/A N/A
COAXIAL
CABLE SUNCITY J400/
30CM
APR. 2006
SRT
COAXIAL
CABLE TIME LMR-400/
4M
APR. 2006
SRT
NOTE: The calibration interval of the above test equipment is one year and the calibrations are
traceable to NML/ROC and NIST/USA.
6.2 TEST PROCEDURE
According to IEC/EN 61000-4-3:1995+A1:1998
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:28 of 28
Date: Oct. 08, 2005
6.3 TEST SETUP
NOTE :
1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT.
2. For the actual test configuration, please refer to the photos of testing.
1.1m
door
balun to Absorber/Tile
Ant.
2.75m Absorber Location
1.5m
2.2m 1.85m 0.24m
chamber (7m x 3m x 3m)
Absorber
Optical Fiber
Coaxial Cable
Power
A
mplifier
Signal
Generator
V/M
Monitor
Monitor
3 m
Sensor
Wooden
table
EUT CCD
Absorber
1.5m
0.8 m
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:29 of 29
Date: Oct. 08, 2005
6.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
6.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
6.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency : 230V/50Hz, single phase
(2) Sweeping frequency : 80MHz 1 GHz
(3) Test level : 3V/m, the frequncy step is 1%
(4) The four sides of EUT are tested : front, rear, left, right
(5) Modulation : 80%AM, 1kHz Dwell time for each
frequency is 3 sec.
(6) Antenna Polarization : Horizontal and Vertical
(7) Standard requirement : Criterion A
2. Performance criterion
(1) Criterion A : Normal performance during test
(2) Criterion B : Temporary degradation or loss of function or
performance which is self-recoverable.
(3) Criterion C : Temporary degradation or loss of function
or performance which requires operator
intervention system reset.
6.7 TEST RESULT
Temperature: 24°C Humidity: 56% RH
Test Object: EUT1+EUT2 Tested By: Tom Lin
Tested Date: Aug. 13, 2003
Test Result : Criterion A pass
TEST RESULT
(CRITERION)
FREQUENCY LEVEL MODULATION DIRECTION H V
80MHz - 1GHz 3V/m 80%AM, 1kHz FRONT A A
80MHz - 1GHz 3V/m 80%AM, 1kHz REAR A A
80MHz - 1GHz 3V/m 80%AM, 1kHz LEFT A A
80MHz - 1GHz 3V/m 80%AM, 1kHz RIGHT A A
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:30 of 30
Date: Oct. 08, 2005
7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST
7.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL #
DUE DATE OF CAL &
CAL CENTER
EFT GENERATOR HAEFELY PEFT-JUNIOR /
583-333-122
NOV. 2005
ETC
CLAMP HAEFELY TRENCH /
080421-12
NOV. 2005
ETC
GROUND PLANE
2M x 3M SRT N/A APR. 2006
SRT
7.2 TEST PROCEDURE
According to IEC/EN 61000-4-4:1995
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:31 of 31
Date: Oct. 08, 2005
7.3 TEST SET-UP
NOTE :
1. The EUT system was put on a wooden table with 0.8m height for table top EUT and 0.1m for
floor-standing EUT above ground reference plane.
2. For the actual test configuration, please refer to the photos of testing.
3. The minimum distance between the EUT and all other conductive structure was more than 0.5m.
4. The minimum distance between the coupling plates of the coupling clamps (if used) and all over
conductive structures, except the ground plane beneath the coupling clamp and beneath the EUT was
more than 0.5m.
5. The power cable connecting EUT was controlled under 1m.
7.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
7.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
Auxiliary
Equipment
Auxiliary
Equipment
Clamp
EUT
Power
EFT Wave
Generator
I/O and communication ports
Auxiliary
Equipment
Load EUT EFT Wave
Generator
Power Cable
Power supply ports
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:32 of 32
Date: Oct. 08, 2005
7.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency : 230V/50Hz, single phase
(2) Pulse risetime and duration : 5ns / 50ns
(3) Pulse repetition : 5kHz
(4) Polarity : Positive Polarization and Negative
Polarization
(5) Burst duration and period : 15ms / 300ms
(6) Test duration : 61sec each line
(7) Time between test : 10Sec
(8) Severity levels : Power Line ±1kV
Signal/Control Line ±0.5kV
(9) Standard requirement : Criterion B
2. Performance criterion
(1) Criterion A : Normal performance during test
(2) Criterion B : Temporary degradation or loss of function or
performance which is self-recoverable.
(3) Criterion C : Temporary degradation or loss of function
or performance which requires operator
intervention system reset.
7.7 SUMMARY OF TEST RESULT
Temperature: 24 °C Humidity: 54% RH
Test Object: EUT1+EUT2 Tested By: Tom Lin
Atmospheric Air Pressure: 101.2 kPa Tested Date: Aug. 13, 2003
Test Result : Criterion A pass
Voltage 0.5kV 1kV
Polarity + - + -
L1 A A A A
L2 A A A A
GND A A A A
Test
Line
Signal/
Control Line NR NR NR NR
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
NR: No requirement
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:33 of 33
Date: Oct. 08, 2005
8. SURGE TEST (POWER LINE)
8.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL # DUE DATE OF CAL.
& CAL. CENTER
SURGE TEST
(System Mainframe) SCHAFFNER NSG 2050 /
199904-057SC
OCT. 2005
ETC
SURGE TEST
(Impulse Network) SCHAFFNER PNW 2050 /
256
OCT. 2005
ETC
SURGE TEST
(Pulse Coupling Network) SCHAFFNER CDN 131/133 /
520
OCT. 2005
ETC
8.2 TEST PROCEDURE
According to IEC/EN 61000-4-5:1995
8.3 TEST SET-UP
NOTE :
1. The EUT system was put on a wooden table with 0.8m height above ground reference plane.
2. For the actual test configuration, please refer to the photos of testing.
8.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
8.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
Auxiliary
Equipment
SURGE
GENERATOR EUT
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:34 of 34
Date: Oct. 08, 2005
8.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Test level : Common mode : ±0.5kV, ±1kV, ±2kV
Differential mode : ±0.25kV, ±0.5kV, ±1kV
(2) Number of Pulse : 5
(3) Phase : 0°, 90°, 180°, 270°
(4) Polarity : Positive and Negative polarization
(5) Repetition : 60 s
(6) Waveform : 1.2/50 µs (open circuit)
(7) Standard requirement : Criterion B
2. Performance criterion
(1) Criterion A : Normal performance during test
(2) Criterion B : Temporary degradation or loss of function
or performance which is self-recoverable
(3) Criterion C : Temporary degradation or loss of function
or performance which requires operator
intervention system reset
8.7 SUMMARY OF TEST RESULT
Temperature: 24 °C Humidity: 58% RH
Test Object: EUT2 Tested By: Tom Lin
Atmospheric Air Pressure: 101.2 kPa Tested Date: Aug. 13, 2003
Test Result : Criterion A pass
Phase
Mode Coupling Voltage 90° 180° 270°
+/-0.5kV A A A A
+/-1kV A A A A
Common L + PE
N + PE
+/-2kV A A A A
+/-0.25kV A A A A
+/-0.5kV A A A A
Differential L + N
+/-1kV A A A A
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:35 of 35
Date: Oct. 08, 2005
9. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST
9.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL # DUE DATE OF CAL.
& CAL. CENTER
FINAL
TEST BE
USED
EM INJECTION
CLAMP FCC F-203I-23mm/
110
MAY 2006
ETC
POWER LINE CDN FCC FCC-801-M4-32A/
9808
MAY 2006
ETC
POWER LINE CDN FCC FCC-801-M5-32A/
9812
MAY 2006
ETC
POWER LINE CDN FCC FCC-801-M1-32A/
9820
MAY 2006
ETC
SIGNAL LINE CDN FCC FCC-801-T2/
9830
MAY 2006
ETC
SIGNAL LINE CDN FCC FCC-801-T4/
9831
MAY 2006
ETC
SIGNAL LINE CDN FCC FCC-801-T6/
9832
MAY 2006
ETC
SIGNAL LINE CDN FCC FCC-801-S9/
9843
MAY 2006
ETC
POWER LINE CDN FCC FCC-801-M2-32A/
9840
NOV. 2005
ETC
SIGNAL
GENERATOR HP 8648A/
3636A02776
JUN. 2006
ETC
POWER AMPLIFIER A.R. 150A100A/
19553
MAY 2006
ETC
DUAL DIRECTION
COULPER A.R. DC2600/
25893
SEP. 2006
ETC
POWER METER BOONTON 4232A/
29001
MAY 2006
ETC
SIGNAL LINE CDN FCC FCC-801-S25/
9845
MAY 2006
ETC
POWER LINE CDN FCC FCC-801-M3-32A/
9874
MAY 2006
ETC
T2 EM-TEST
ATT6/75/
1001-40 N/A
COAXIAL CABLE SUNCITY CABLE14/
#14-1M
APR. 2006
SRT
COAXIAL CABLE SUNCITY CABLE05/
#5-5M
APR. 2006
SRT
COAXIAL CABLE SUNCITY J400/
2M
APR. 2006
SRT
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:36 of 36
Date: Oct. 08, 2005
9.2 TEST PROCEDURE
According to IEC/EN 61000-4-6:1996
9.3 TEST SET-UP
(1) For CDN injection :
(2) For Clamp injection :
NOTE :
1. The EUT system was put on a wooden table with 0.1m height above ground.
2. For the actual test configuration, please refer to the photos of testing.
3. The distance between CDN(Clamp) and EUT was controlled between 0.1m and 0.3m.
4. The model no. of the CDN connected to EUT is FCC-801-M3-32A.
9.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
9.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
Power
A
m
p
lifier
CDN
T2
EUT
Auxiliary Equipment
SIGNAL
GENERATOR
Coaxial
Cable
SIGNAL
GENERATOR
Power
Amplifier T2 Injection
Clamp
Monitoring Probe
EUT
Auxiliary Equipment
Receiver
Coaxial
Cable
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:37 of 37
Date: Oct. 08, 2005
9.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency : 230 V/ 50 Hz, single phase
(2) Sweeping frequency : 150 kHz 80 MHz
(3) Test level : 3 V, the frequency step is 1%
(4) Modulation : AM 80%, 1 kHz
(5) Dwell time for each frequency : 3 sec
(6) Standard requirement : Criterion A
2. Performance criterion
(1) Criterion A : Normal performance during test
(2) Criterion B : Temporary degradation or loss of function
or performance which is self-recoverable
(3) Criterion C : Temporary degradation or loss of function
or performance which requires operator
intervention system reset
9.7 SUMMARY OF TEST RESULT
Temperature: 24°C Humidity: 51% RH
Test Object: EUT1 Tested By: Tom Lin
Test Result : Criterion A pass Tested Date: Aug. 13, 2003
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
FREQUENCY LEVEL MODULATION INJECTION
METHOD TEST RESULT
(CRITERION)
150kHz - 80MHz 3V 80% AM, 1 kHz M3 A
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:38 of 38
Date: Oct. 08, 2005
Temperature: 24°C Humidity: 51% RH
Test Object: EUT2 Tested By: Tom Lin
Test Result : Criterion A pass Tested Date: Aug. 13, 2003
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
FREQUENCY LEVEL MODULATION INJECTION
METHOD TEST RESULT
(CRITERION)
150kHz - 80MHz 3V 80% AM, 1 kHz M2 A
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:39 of 39
Date: Oct. 08, 2005
10. POWER FREQUENCY MAGNETIC-FIELD TEST
10.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL #
DUE DATE OF CAL.
& CAL. CENTER
MAGNETIC FIELD
TESTER HAEFELY MAG 100.1/
080.015-04
JAN. 2006
SRT
MAGNETIC FIELD
COIL HAEFELY MAG 100.1/
080.015-04
JAN. 2006
SRT
MAGNETIC FIELD
METER F.W.BELL 4080/
19990416
MAR. 2006
ITRI
10.2 TEST PROCEDURE
According to IEC/EN 61000-4-8:1993
10.3 TEST SET-UP
NOTE :
1. The EUT system was put on a wooden table with 0.8m height above ground.
2. For the actual test configuration, please refer to the photos of testing
3. 1A/m = 12.56mG, 3A/m = 37.68mG, 10A/m = 125.6mG,
10.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
EUT
Frequency Converter
Test Generator
Magnetic Coil
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:40 of 40
Date: Oct. 08, 2005
10.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
10.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Test axis : X, Y and Z axes
(2) Test time : 5 min / each axis
(3) Field strength : 3 A/m
(4) Standard requirement : Criterion A
2. Performance criterion
(1) Criterion A : Normal performance during test
(2) Criterion B : Temporary degradation or loss of function
or performance which is self-recoverable
(3) Criterion C : Temporary degradation or loss of function
or performance which requires operator
intervention system reset
10.7 SUMMARY OF TEST RESULT
Temperature: 24°C Humidity: 54%H
Test Object: EUT1+EUT2 Tested By: Tom Lin
Frequency of Magnetic Field: 50Hz, 60Hz Tested Date: Aug. 14, 2003
Test Result : Criterion A pass
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
ORIENTATION FIELD
STRENGTH TEST RESULT
(CRITERION)
X 3 A/m A
Y 3 A/m A
Z 3 A/m A
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:41 of 41
Date: Oct. 08, 2005
11. VOLTAGE DIPS, INTERRUPTS, VARIATIONS TEST
11.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL #
DUE DATE OF CAL.
& CAL. CENTER
INTERFERENCE
SIMULATOR HAEFELY PLINE 1610/
083-732-05
APR. 2006
ETC
11.2 TEST PROCEDURE
According to IEC/EN 61000-4-11:1994
11.3 TEST SET-UP
NOTE :
1. The EUT system was put on a wooden table with 0.8m height above ground.
2. For the actual test configuration, please refer to the photos of testing.
11.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
11.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
Frequency
Converter
Interference
Simulator EUT Auxiliary Equipment
Power cable
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:42 of 42
Date: Oct. 08, 2005
11.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency : 230V/50Hz, single phase
(2) Test level : Dip depth 95%, 0.5 period
30%, 25 period
Interrupt 95%, 250 period
(3) Phase : 0°, 180°
(4) Test duration : 2min each phase
(5) Time between test : 10 sec
(6) Standard requirement : Dip 95% : Criterion B;
Dip 30% : Criterion C;
Interrupt > 95%: Criterion C
2. Performance criterion
(1) Criterion A : Normal performance during test
(2) Criterion B : Temporary degradation or loss of function
or performance which is self-recoverable.
(3) Criterion C : Temporary degradation or loss of function
or performance which requires operator
intervention system reset.
11.7 SUMMARY OF TEST RESULT
Temperature: 24°C Humidity: 54% RH
Test Object: EUT2 Tested By: Tom Lin
Tested Date: Aug. 14, 2003
NOTE:
1. The power voltage range: 100V to 240V, and the range 140V is 140% of the lowest voltage.
2. Description of test observation:
A: There was no change compared with initial operation during the test.
B: EUT delayed in data copy during testing.
AC
POWER DIP
DEPTH INTERVAL DIP TIME TEST TIME PHASE TEST
RESULT
(Criterion)
0° A
95% 10 sec 0.5 period 2 min 180° A
0° A
30% 10 sec 25 period 2 min 180° A
0° B
230V/50Hz
95%
(interrupt) 10 sec 250 period 2 min 180° B
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:43 of 43
Date: Oct. 08, 2005
12. PHOTOS OF TESTING
- Conducted test (EUT1)
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:44 of 44
Date: Oct. 08, 2005
- Conducted test (EUT2)
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:45 of 45
Date: Oct. 08, 2005
- Radiated test (EUT1+EUT2)
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:46 of 46
Date: Oct. 08, 2005
- Harmonics test (EUT2)
- Voltage fluctuations test (EUT2)
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:47 of 47
Date: Oct. 08, 2005
- Electrostatic discharge immunity test (EUT1+EUT2)
- Electrical fast transient / burst immunity test (EUT1+EUT2)
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:48 of 48
Date: Oct. 08, 2005
- Radiated immunity test (EUT1+EUT2)
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:49 of 49
Date: Oct. 08, 2005
-Surge test (power line) (EUT2)
- Inducted RF fields (conducted susceptibility) test (EUT1)
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:50 of 50
Date: Oct. 08, 2005
- Inducted RF fields (conducted susceptibility) test (EUT2)
- Power frequency magnetic-field test (EUT1+EUT2)
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:51 of 51
Date: Oct. 08, 2005
- Voltage dips, interrupts, variations test (EUT2)
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.:A05100404
Report No.:EMCA03051901-02
Page:52 of 52
Date: Oct. 08, 2005
13. TERMS OF ABRIVATION
AV. Average detection
AZ(°) Turn table azimuth
Correct. Correction
EL(m) Antenna height (meter)
EUT Equipment Under Test
Horiz. Horizontal direction
LISN Line Impedance Stabilization Network
NSA Normalized Site Attenuation
Q.P. Quasi-peak detection
SRT Lab Spectrum Research & Testing Laboratory, Inc.
Vert. Vertical direction