EMCA06051501 158008,158015 EMC Report Lycom

2016-04-05

: Pdf 158008,158015 Emc Report Lycom 158008,158015_EMC__report--Lycom CertsReports 158015 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 38

Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:2 of 38
Date: Jan. 24, 2007.
Table of Contents
1. DOCUMENT POLICY AND TEST STATEMENT ................................................ 4
1.1 DOCUMENT POLICY .........................................................................................4
1.2 TEST STATEMENT.............................................................................................4
1.3 EUT MODIFICATION ..........................................................................................4
2. DESCRIPTION OF EUT AND TEST MODE....................................................... 5
2.1 GENERAL DESCRIPTION OF EUT ...................................................................5
2.2 DESCRIPTION OF EUT INTERNAL DEVICE.....................................................5
2.3 DESCRIPTION OF TEST MODE........................................................................5
3. DESCRIPTION OF APPLIED STANDARDS ...................................................... 6
4. EMISSION TEST................................................................................................ 7
4.1 CONDUCTED EMISSION TEST FOR MAIN PORT ...........................................7
4.1.1 CONDUCTED EMISSION LIMIT ........................................................................7
4.1.2 TEST EQUIPMENT ............................................................................................7
4.1.3 TEST SETUP......................................................................................................8
4.1.4 TEST PROCEDURE...........................................................................................8
4.1.5 DESCRIPTION OF SUPPORT UNIT..................................................................9
4.1.6 EUT OPERATING CONDITION..........................................................................9
4.1.7 TEST RESULT..................................................................................................10
4.2 RADIATED EMISSION TEST............................................................................11
4.2.1 RADIATED EMISSION LIMIT ...........................................................................11
4.2.2 TEST EQUIPMENT ..........................................................................................11
4.2.3 TEST SET-UP...................................................................................................12
4.2.4 TEST PROCEDURE.........................................................................................12
4.2.5 DESCRIPTION OF SUPPORT UNIT................................................................13
4.2.6 EUT OPERATING CONDITION........................................................................13
4.2.7 TEST RESULT..................................................................................................14
5. ELECTROSTATIC DISCHARGE IMMUNITY TEST........................................... 15
5.1 TEST EQUIPMENT...........................................................................................15
5.2 TEST PROCEDURE .........................................................................................15
5.3 TEST SET-UP...................................................................................................16
5.4 DESCRIPTION OF SUPPORT UNIT ................................................................17
5.5 EUT OPERATING CONDITION........................................................................17
5.6 TEST CONDITION AND PERFORMANCE CRITERION ..................................17
5.7 SUMMARY OF TEST RESULT .........................................................................18
6. RADIATED IMMUNITY TEST ............................................................................ 19
6.1 TEST EQUIPMENT...........................................................................................19
6.2 TEST PROCEDURE .........................................................................................20
6.3 TEST SETUP....................................................................................................21
6.4 DESCRIPTION OF SUPPORT UNIT ................................................................22
6.5 EUT OPERATING CONDITION........................................................................22
6.6 TEST CONDITION / PERFORMANCE CRITERIA ...........................................22
6.7 TEST RESULT ..................................................................................................23
7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST .......................... 24
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:3 of 38
Date: Jan. 24, 2007.
7.1 TEST EQUIPMENT...........................................................................................24
7.2 TEST PROCEDURE .........................................................................................24
7.3 TEST SET-UP...................................................................................................25
7.4 DESCRIPTION OF SUPPORT UNIT ................................................................25
7.5 EUT OPERATING CONDITION........................................................................25
7.6 TEST CONDITION / PERFORMANCE CRITERIA ...........................................26
7.7 SUMMARY OF TEST RESULT .........................................................................27
8. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST ..................... 28
8.1 TEST EQUIPMENT...........................................................................................28
8.2 TEST PROCEDURE .........................................................................................29
8.3 TEST SET-UP...................................................................................................29
8.4 DESCRIPTION OF SUPPORT UNIT ................................................................29
8.5 EUT OPERATING CONDITION........................................................................29
8.6 TEST CONDITION / PERFORMANCE CRITERIA ...........................................30
8.7 SUMMARY OF TEST RESULT .........................................................................30
9. POWER FREQUENCY MAGNETIC-FIELD TEST............................................. 31
9.1 TEST EQUIPMENT...........................................................................................31
9.2 TEST PROCEDURE .........................................................................................31
9.3 TEST SET-UP...................................................................................................31
9.4 DESCRIPTION OF SUPPORT UNIT ................................................................31
9.5 EUT OPERATING CONDITION........................................................................32
9.6 TEST CONDITION / PERFORMANCE CRITERIA ...........................................32
9.7 SUMMARY OF TEST RESULT .........................................................................32
10.1 PHOTOS OF TESTING ................................................................................. 33
11. TERMS OF ABBREVIATION............................................................................ 38
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:4 of 38
Date: Jan. 24, 2007.
1. DOCUMENT POLICY AND TEST STATEMENT
1.1 DOCUMENT POLICY
- The report shall not be reproduced except in full, without the written approval of SRT
Lab, Inc.
- The report must not be used by the applicant to claim that the product is endorsed by
NVLAP, TÜV, NEMKO and SRT.
- The NVLAP logo applies only to the applicable standards specified in this report.
1.2 TEST STATEMENT
- The test results in the report apply only to the unit tested by SRT Lab.
- There was no deviation from the requirements of test standards during the test.
- AC power source, 230 VAC/50 Hz, was used during the test.
- The EN 61000-3-2 edition 2:2000(Harmonic test) and EN 61000-3-3:1995+A1:2001
(Flicker test) are not included in the scope of NVLAP logo usage.
- The EN 61000-3-2 edition 2:2000(Harmonic test) and EN 61000-3-3:1995+A1:2001
(Flicker test) are included in the scope of TÜV, NEMKO and SRT logo usage.
1.3 EUT MODIFICATION
- No modification in SRT Lab.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:5 of 38
Date: Jan. 24, 2007.
2. DESCRIPTION OF EUT AND TEST MODE
2.1 GENERAL DESCRIPTION OF EUT
PRODUCT ExpressCard /34
MODEL NO. EK-103,EK-104,EK-105,EK-108,EK-110,EK-202
POWER SUPPLY DC from PC
CABLE N/A
TYPE Prototype
NOTE :
The EUT has eight model numbers as below on market. They are identical in all aspects except for the
software.
For more detailed information, please refer to the EUT’s specification or user’s manual provided by
manufacturer.
2.2 DESCRIPTION OF EUT INTERNAL DEVICE
DEVICE BRAND / MAKER MODEL # REMARK
N/A
NOTE :
1. The highest clock is 25MHz.
2. Frequency range to be measured.
Radiated emission is 30 MHz to 1 GHz.
2.3 DESCRIPTION OF TEST MODE
N/A (It is only applicable to more than one test mode.)
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:6 of 38
Date: Jan. 24, 2007.
3. DESCRIPTION OF APPLIED STANDARDS
The EUT is a kind of ITE interface device and according to the specifications provided by
the applicant, it must comply with the requirements of the following standards:
EN 55022:1998+A1:2000+A2:2003, Class B EN 55024:1998+A1:2001+A2:2003
- IEC 61000-4-2:1995+A1:1998+A2:2001
- IEC 61000-4-3:1995+A1:1998+A2:2002
- IEC 61000-4-4:2004
- IEC 61000-4-6:2004
- IEC 61000-4-8:2001
But the standards of EN 61000-3-2, EN 61000-3-3, IEC 61000-4-5 and IEC 61000-4-11
were not measured, because the EUT’s power source is DC from PC.
All tests have been performed and recorded as the above standards.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:7 of 38
Date: Jan. 24, 2007.
4. EMISSION TEST
4.1 CONDUCTED EMISSION TEST FOR MAIN PORT
4.1.1 CONDUCTED EMISSION LIMIT
Class A (dBµV) Class B (dBµV)
FREQUENCY (MHz) Quasi-peak Average Quasi-peak Average
0.15 - 0.5 79 66 66 - 56 56 - 46
0.5 - 5.0 73 60 56 46
5.0 - 30.0 73 60 60 50
NOTE:
1. The lower limit shall apply at the transition frequencies.
2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.
4.1.2 TEST EQUIPMENT
The following test equipment was used for the test:
EQUIPMENT/
FACILITIES SPECIFICATIONS MANUFACTURER MODEL#/
SERIAL#
DUE DATE OF CAL.
& CAL. CENTER
EMI TEST
RECEIVER
9 kHz TO
30 MHz
ROHDE &
SCHWARZ
ESHS30/
826003/008
AUG. 2006
ETC
LISN (for EUT) 50 µH, 50 ohm FCC FCC-LISN-50-25-2
/ 01017
NOV. 2006
ETC
LISN
(for Peripheral) 50 µH, 50 ohm FCC FCC-LISN-50-25-2
/ 01018
OCT. 2006
ETC
50 ohm
TERMINATOR 50 ohm HP 11593A/
2
OCT. 2006
ETC
COAXIAL
CABLE 5m SUNCITY CABLE/#5-5M JUL. 2006
SRT
ISOLATION
TRANSFORMER N/A APC AFC-11015/
F102040016 N/A
FILTER 2 LINE, 30A FIL.COIL FC-943/
771 N/A
GROUND PLANE 2.3M (H) x
2.4M (W) SRT N/A N/A
GROUND PLANE 2.4M (H) x
2.4M (W) SRT N/A N/A
NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable
to NML/ROC and NIST/USA.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:8 of 38
Date: Jan. 24, 2007.
4.1.3 TEST SETUP
NOTE:
1. The EUT was put on a wooden table with 0.8m height above ground plane, and 0.4m away from
reference ground plane (> 2mx2m).
2. For the actual test configuration, please refer to the photos of testing.
3. The serial no. of the LISN connected to EUT is 01017.
4. The serial no. of the LISN connected to support units is 01018.
4.1.4 TEST PROCEDURE
The EUT was tested according to the requirement of EN 55022:1998+A1:2000+A2:2003.
The frequency spectrum from 0.15 MHz to 30 MHz was investigated. The LISN used was
50/50µH as specified. All readings were quasi-peak and average values with 10 kHz
resolution bandwidth of the test receiver. The EUT system was operated in all typical
methods by users. Both lines of the power mains of EUT were measured and the cables
connected to EUT and support units were moved to find the maximum emission levels for
each frequency.
First, find the margin or higher points at least 6 points by software, then use manual to
find the maximum data. The procedure is referred on the test procedure of SRT LAB.
Isolation
Transformer Filter LISN
LISN
EUT
Support Units
EMI TEST
Receiver
To Utility
Power
Coaxial Cable
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:9 of 38
Date: Jan. 24, 2007.
4.1.5 DESCRIPTION OF SUPPORT UNIT
The EUT was configured by the requirement of EN 55022:1998+A1:2000+A2:2003. All
interface ports were connected to the appropriate support units via specific cables. The
support units and cables are listed below.
NO DEVICE BRAND MODEL # CABLE
1 PC ACER AS-T650- 1.8m unshielded power cord
2 MONITOR SAMSUNG PG17IS 1.5m unshielded power cord
1.2m shielded data cable
3 SATA HDD VANTEC NEXSTAR.3 3.0m unshielded power cord
1.0m unshielded data cable
4 PRINTER EPSON STYLUS C20SX 1.5m unshielded power cord
1.5m shielded data cable
5 MODEM ACEEX DM-1414 1.8m unshielded DC power cable
1.5m shielded data cable
6 KEYBOARD IBM SK-8820 1.5m unshielded data cable
7 MOUSE IBM MU29J 1.5m unshielded data cable
NOTE: For the actual test configuration, please refer to the photos of testing.
4.1.6 EUT OPERATING CONDITION
1. Under Windows XP ran “EMITEST” and “XCOPY” programs.
2. EUT sent "H" pattern or accessed the following peripherals directly:
- Color Monitor
- RS232
- Keyboard
- Mouse
- Printer
- FDD
- HDD
3. XCOPY
:loop
XCOPY C:\test E:\/s/y
Go to loop
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:10 of 38
Date: Jan. 24, 2007.
4.1.7 TEST RESULT
Temperature: 25°C Humidity: 87%RH
Ferquency Range: 0.15 – 30 MHz Tested Mode: N/A
Receiver Detector: Q.P. and AV. Tested By: Sunyou Chen
Tested Date: May 15, 2006
Power Line Measured : Line
Reading Value
(dBµV)
Emission Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Freq.
(MHz)
Correct.
Factor
(dB) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV.
0.477 0.25 41.20 40.89 41.45 41.14 56.39 46.39 -14.94 -5.25
0.480 0.25 41.02 40.47 41.27 40.72 56.34 46.34 -15.07 -5.62
0.682 0.22 35.72 32.18 35.94 32.40 56.00 46.00 -20.06 -13.60
1.230 0.14 32.92 31.65 33.06 31.79 56.00 46.00 -22.94 -14.21
2.804 0.18 31.20 26.68 31.38 26.86 56.00 46.00 -24.62 -19.14
9.628 0.23 33.46 29.93 33.69 30.16 60.00 50.00 -26.31 -19.84
Power Line Measured : Neutral
Reading Value
(dBµV)
Emission Level
(dBµV)
Limit
(dBµV)
Margin
(dB)
Freq.
(MHz)
Correct.
Factor
(dB) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV.
0.477 0.25 45.26 45.21 45.51 45.46 56.39 46.39 -10.88 -0.93
0.480 0.25 45.04 44.91 45.29 45.16 56.34 46.34 -11.05 -1.18
0.682 0.22 38.52 35.26 38.74 35.48 56.00 46.00 -17.26 -10.52
1.438 0.15 37.44 35.15 37.59 35.30 56.00 46.00 -18.41 -10.70
2.734 0.17 37.68 32.11 37.85 32.28 56.00 46.00 -18.15 -13.72
8.126 0.23 36.70 33.78 36.93 34.01 60.00 50.00 -23.07 -15.99
NOTE :
1. Measurement uncertainty is +/-1.32dB
2. Emission level = Reading value + Correction factor
3. Correction Factor = Cable loss + Insertion loss of LISN
4. Margin value = Emission level - Limit
5. The emission of other frequencies were very low against the limit.
6. "-": The Quasi-peak reading value also meets average limit and measurement with the average
detector is unnecessary.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:11 of 38
Date: Jan. 24, 2007.
4.2 RADIATED EMISSION TEST
4.2.1 RADIATED EMISSION LIMIT
EN 55022:1998+A1:2000+A2:2003 limits of radiated emission measurement for
frequency below 1000 MHz
Class A (at 10m) Class B (at 10m)
FREQUENCY (MHz) dBµV/m dBµV/m
30 – 230 40 30
230 - 1000 47 37
NOTE:
1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBµV/m) = 20 log Emission level (µV/m).
4.2.2 TEST EQUIPMENT
The following test equipment was used during the radiated emission test:
EQUIPMENT/
FACILITIES SPECIFICATIONS MANUFACTURER MODEL#/
SERIAL#
DUE DATE OF CAL. &
CAL. CENTER
EMI TEST
RECEIVER
9 kHz TO
2.75 GHz
ROHDE &
SCHWARZ
ESCS30/
830245/012
OCT. 2006
ETC
BI-LOG
ANTENNA
25 MHz TO
2 GHz EMCO 3143/
9509-1141
OCT. 2006
SRT
OATS 3 – 10 M
MEASUREMENT SRT SRT-1 DEC. 2006
SRT
COAXIAL
CABLE 25M SUNCITY J400-25M-2NP/
#153-25M
JUN. 2006
SRT
FILTER 2 LINE, 30A FIL.COIL FC-943/
869 N/A
FREQUENCY
CONVERTER N/A APC AFC-2KBB/
F100030031
AUG. 2006
SRT
NOTE:
1. The calibration interval of the above test equipment is one year and the calibrations are traceable to
NML/ROC and NIST/USA.
2. The Open Area Test Site (SRT-1) is registered by FCC with No. 90957 and VCCI with No. R-1081.
3. The Open Area Test Site (SRT-2) is registered by FCC with No. 98458 and VCCI with No. R-1168.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:12 of 38
Date: Jan. 24, 2007.
4.2.3 TEST SET-UP
NOTE:
1. The EUT system was put on a wooden table with 0.8m heights above a ground plane.
2. For the actual test configuration, please refer to the photos of testing.
4.2.4 TEST PROCEDURE
The EUT was tested according to the requirement of EN 55022:1998+A1:2000+A2:2003.
The measurements were made at an open area test site with 10 meter measurement
distance. The frequency spectrum measured from 30 MHz to 1 GHz. All readings were
quasi-peak values with 120 kHz resolution bandwidth of the test receiver. The EUT
system was operated in all typical methods by users. The cables connected to EUT and
support units were moved to find the maximum emission levels for each frequency.
First, find the margin or higher points at least 6 points by software, then use manual to
find the maximum data. The procedure is referred on the test procedure of SRT LAB.
EMI Receiver
Filter To Utility
Power
EUT
Ground Plane
3/10m
0.8 m
Coaxial
Cable
Turn Table
1m – 4m
Power Cable
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:13 of 38
Date: Jan. 24, 2007.
4.2.5 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
4.2.6 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:14 of 38
Date: Jan. 24, 2007.
4.2.7 TEST RESULT
Temperature: 25 °C Humidity: 87 %RH
Ferquency Range: 0.15 – 30 MHz Tested Mode: N/A
Receiver Detector: Q.P. and AV. Tested By: Sunyou Chen
Tested Date: May 05, 2006
Antenna Polarization: Horizontal
Frequency
(MHz)
Cable
Loss
(dB)
Antenna
Factor
(dB)
Reading
Data
(dBµV)
Emission
Level
(dBµV/m)
Limit
(dBµV/m)
Margin
(dB) AZ(°) EL(m)
0.477 0.25 45.30 44.95 45.55 45.20 56.39 46.39 -10.84
0.480 0.25 45.02 44.49 45.27 44.74 56.34 46.34 -11.07
1.162 0.14 38.68 37.06 38.82 37.20 56.00 46.00 -17.18
2.665 0.17 39.56 36.90 39.73 37.07 56.00 46.00 -16.27
2.804 0.18 36.08 33.18 36.26 33.36 56.00 46.00 -19.74
11.268 0.23 35.94 30.25 36.17 30.48 60.00 50.00 -23.83
Antenna Polarization:Vertical
Frequency
(MHz)
Cable
Loss
(dB)
Antenna
Factor
(dB)
Reading
Data
(dBµV)
Emission
Level
(dBµV/m)
Limit
(dBµV/m)
Margin
(dB) AZ(°) EL(m)
0.477 0.25 45.50 44.91 45.75 45.16 56.39 46.39 -10.64
0.480 0.25 45.30 44.49 45.55 44.74 56.34 46.34 -10.79
1.162 0.14 39.06 37.14 39.20 37.28 56.00 46.00 -16.80
2.665 0.17 39.72 36.74 39.89 36.91 56.00 46.00 -16.11
8.471 0.23 37.74 31.97 37.97 32.20 60.00 50.00 -22.03
9.222 0.23 38.54 34.89 38.77 35.12 60.00 50.00 -21.23
NOTE :
1. Measurement uncertainty is +/-2dB.
2. "*": Measurement does not apply for this frequency.
3. Emissiom Level = Reading Value + Ant. Factor + Cable Loss.
4. The field strength of other emission frequencies were very low against the limit.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:15 of 38
Date: Jan. 24, 2007.
5. ELECTROSTATIC DISCHARGE IMMUNITY TEST
5.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL #
DUE DATE OF CAL.
& CAL. CENTER
ESD SIMULATOR NOISEKEN ESS-100L(A)/TC-815P/
8099C02238/7099C02
OCT. 2006
ETC
HCP (1.6M x 0.8M) SRT WITH TWO 470k OHM
CABLE N/A
VCP (0.5M x 0.5M) SRT WITH TWO 470k OHM
CABLE N/A
GROUND PLANE
(3.4M x 2.4M) SRT N/A N/A
NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable
to NML/ROC and NIST/USA.
5.2 TEST PROCEDURE
According to IEC/EN 61000-4-2:1995+A1:1998+A2:2001
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:16 of 38
Date: Jan. 24, 2007.
5.3 TEST SET-UP
NOTE :
1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT.
2. For the actual test configuration, please refer to the photos of testing.
3. A distance of 1m minimum was provided between EUT and walls / other metallic structure.
Insulating Support
ESD Gun
Return
Cable
EUT System
Vertical Coupling Plane
Ground Reference Plane
Horizontal Coupling
Plane
Wooden Table
470k
470k
10 cm
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:17 of 38
Date: Jan. 24, 2007.
5.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
5.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
5.6 TEST CONDITION AND PERFORMANCE CRITERION
1. Test condition
(1) R-C Network :330 , 150 pF
(2) Test level: Air Discharge :±2kV, ±4kV, ±8kV
Contact discharge :±2kV, ±4kV
HCP discharge : ±2kV, ±4kV
VCP discharge : ±2kV, ±4kV
(3) Discharge mode : Single discharge
(4) Discharge period : at least 1 s
(5) Discharge polarity : Positive and Negative
(6) Number of discharge : Minimum 50 times at each test point of contact
discharge and at least 200 times of discharge to
EUT in total. Minium 10 times at each test area
of air discharge selected.
2. Standard requirement : Criterion B
3. Performance criterion
(1) Criterion A :Normal performance during test
(2) Criterion B :Temporary degradation or loss of function or
performance which is self-recoverable
(3) Criterion C :Temporary degradation or loss of function or
performance which requires operator
intervention system reset
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:18 of 38
Date: Jan. 24, 2007.
5.7 SUMMARY OF TEST RESULT
Temperature: 23°C Humidity: 50% RH
Tested Mode: N/A Tested By: Sunyou Chen
A
tmospheric Air Pressure: 101.2kPa Tested Date: May 15, 2006
Test Result: Criterion B pass
COUPLING MODE & TEST OBSERVATION
SEVERITY
LEVEL AIR
DISCHARGE CONTACT
DISCHARGE HCP VCP
±2kV A B A A
±4kV A B A A
±8kV A NR NR NR
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
B: EUT was delayed when copied data during the test.
NR: No requirement
Description of test points:
1. Connector
2. LED.
3. Enclosure of EUT.
4. HCP.
5. VCP.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:19 of 38
Date: Jan. 24, 2007.
6. RADIATED IMMUNITY TEST
6.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL # DUE DATE OF CAL.
& CAL. CENTER
SIGNAL
GENERATOR HP 8648D/
3847M00637
MAY. 2006
AGLIENT
ANTENNA SCHAFFNER
CHASE
CBL6141A /
4181
OCT. 2006
SRT
FIELD SENSOR AMPLIFIER
RESEARCH
FP2000/
28499
DEC. 2006
ETC
POWER
AMPLIFIER
AMPLIFIER
RESEARCH
100W1000M1/
19509
MAY 2006
ETC
AMPLIFIER A.R. 50S1G4A/
308703
MAY 2006
A.R.
DUAL DIRECTIONAL
COUPLER A.R. DC7420/
308626
MAY. 2006
ETC
ISOTROPIC “E”
FIELD PROBE A.R. FP4080 KIT/
308105
MAY. 2006
A.R.
POWER SENSOR BOONTON 51011SE/ 32966 DEC. 2006
ETC
POWER SENSOR BOONTON 51011CE/ 32964 DEC. 2006
ETC
DUAL DIRECTIONAL
COUPLER A.R. DC6080/
310289
NOV. 2006
ETC.
ANECHOIC
CHAMBER SRT A05/
SRT005
OCT. 2006
SRT
V/M MONITOR A.R. FM2000/
15970 N/A
MONITOR SHIN SI-609/
905130 N/A
CCD TOPVIEW N/A/
95113762 N/A
ABSORBER ETS N/A N/A
COAXIAL
CABLE SUNCITY LMR400/
0.5M AUG. 2006
SRT
COAXIAL
CABLE SUNCITY J400-12M-NP MAY. 2006
SRT
NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable
to NML/ROC and NIST/USA.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:20 of 38
Date: Jan. 24, 2007.
6.2 TEST PROCEDURE
According to IEC/EN 61000-4-3:2002+A1:2002
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:21 of 38
Date: Jan. 24, 2007.
6.3 TEST SETUP
NOTE :
1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT.
2. For the actual test configuration, please refer to the photos of testing.
1.1m
door
balun to Absorber/Tile
Ant.
2.75m Absorber Location
1.5m
2.2m 1.85m 0.24m
chamber (7m x 3m x 3m)
Absorber
Optical Fiber
Coaxial Cable
Power
A
mplifier
Signal
Generator
V/M
Monitor
Monitor
3 m
Sensor
Wooden
table
EUT
CCD
Absorber
1.5m
0.8 m
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:22 of 38
Date: Jan. 24, 2007.
6.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
6.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
6.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency : 230V/50Hz, single phase
(2) Sweeping frequency : 80MHz 1 GHz
(3) Test level : 3V/m, the frequncy step is 1%
(4) The four sides of EUT are tested : front, rear, left, right
(5) Modulation : 80%AM, 1kHz Dwell time for each
frequency is 3 sec.
(6) Antenna Polarization : Horizontal and Vertical
(7) Standard requirement : Criterion A
2. Performance criterion
(1) Criterion A : Normal performance during test
(2) Criterion B : Temporary degradation or loss of function or
performance which is self-recoverable.
(3) Criterion C : Temporary degradation or loss of function
or performance which requires operator
intervention system reset.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:23 of 38
Date: Jan. 24, 2007.
6.7 TEST RESULT
Temperature: 23°C Humidity: 85% RH
Tested Mode: N/A Tested By: Sunyou Chen
Tested Date: May 15, 2006
Test Result : Criterion A pass
TEST RESULT
(CRITERION)
FREQUENCY LEVEL MODULATION DIRECTION H V
80MHz - 1GHz 3V/m 80%AM, 1kHz FRONT A A
80MHz - 1GHz 3V/m 80%AM, 1kHz REAR A A
80MHz - 1GHz 3V/m 80%AM, 1kHz LEFT A A
80MHz - 1GHz 3V/m 80%AM, 1kHz RIGHT A A
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:24 of 38
Date: Jan. 24, 2007.
7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST
7.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL #
DUE DATE OF CAL &
CAL CENTER
EFT GENERATOR HAEFELY PEFT-JUNIOR /
583-333-122
MAY. 2006
ETC
CLAMP HAEFELY TRENCH /
080421-12 N/A
GROUND PLANE
2M x 3M SRT N/A N/A
7.2 TEST PROCEDURE
According to IEC/EN 61000-4-4:1995+A1:2001+A2:2001
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:25 of 38
Date: Jan. 24, 2007.
7.3 TEST SET-UP
NOTE :
1. The EUT system was put on a wooden table with 0.8m height for table top EUT and 0.1m for
floor-standing EUT above ground reference plane.
2. For the actual test configuration, please refer to the photos of testing.
3. The minimum distance between the EUT and all other conductive structure was more than 0.5m.
4. The minimum distance between the coupling plates of the coupling clamps (if used) and all over
conductive structures, except the ground plane beneath the coupling clamp and beneath the EUT was
more than 0.5m.
5. The power cable connecting EUT was controlled under 1m.
7.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
7.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
Auxiliary
Equipment
Auxiliary
Equipment
Clamp
EUT
Power
EFT Wave
Generator
I/O and communication ports
Auxiliary
Equipment
Load EUT EFT Wave
Generator
Power Cable
Power supply ports
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:26 of 38
Date: Jan. 24, 2007.
7.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency : 230V/50Hz, single phase
(2) Pulse risetime and duration : 5ns / 50ns
(3) Pulse repetition : 5kHz
(4) Polarity : Positive Polarization and Negative
Polarization
(5) Burst duration and period : 15ms / 300ms
(6) Test duration : 61sec each line
(7) Time between test : 10Sec
(8) Severity levels :Power Line ±1kV
Signal/Control Line ±0.5kV
(9) Standard requirement : Criterion B
2. Performance criterion
(1) Criterion A : Normal performance during test
(2) Criterion B : Temporary degradation or loss of function or
performance which is self-recoverable.
(3) Criterion C : Temporary degradation or loss of function
or performance which requires operator
intervention system reset.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:27 of 38
Date: Jan. 24, 2007.
7.7 SUMMARY OF TEST RESULT
Temperature: 25 °C Humidity: 87% RH
Tested Mode: N/A Tested By: Sunyou Chen
A
tmospheric Air Pressure: 101.2 kPa Tested Date: May 15, 2006
Test Result : Criterion B pass
Voltage 1kV
Polarity + -
L1 B B
L2 B B
GND B B
Test
Result
Signal/Control Line N/A N/A
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
B: EUT was delayed when copied data during the test.
N/A: Not applicable, as the signal/control line used in typical is less than 3 m.
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:28 of 38
Date: Jan. 24, 2007.
8. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST
8.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL # DUE DATE OF CAL.
& CAL. CENTER
FINAL
TEST BE
USED
EM INJECTION
CLAMP FCC F-203I-23mm/
110
MAY 2006
ETC
POWER LINE CDN FCC FCC-801-M5-32A/
9812
MAY 2006
ETC
POWER LINE CDN FCC FCC-801-M1-32A/
9820
MAY 2006
ETC
SIGNAL LINE CDN FCC FCC-801-T2/
9830
MAY 2006
ETC
SIGNAL LINE CDN FCC FCC-801-T6/
9832
MAY 2006
ETC
SIGNAL LINE CDN FCC FCC-801-T4/
9831
AUG. 2006
ETC
POWER LINE CDN FCC FCC-801-M2-32A/
9840
OCT. 2006
ETC
SIGNAL
GENERATOR R&S SMY01/
841104/019
MAY. 2006
ETC X
POWER AMPLIFIER A.R. 150A100A/
19553
NOV. 2006
ETC X
DUAL DIRECTION
COULPER A.R. DC2600/
25893
OCT. 2006
ETC X
POWER METER BOONON 4232A/
105302
NOV. 2006
ETC X
POWER SENSOR BOONON 51011-EMC/31181 NOV. 2006
ETC X
POWER SENSOR BOONON 51011-EMC/31745 NOV. 2006
ETC X
SIGNAL LINE CDN FCC FCC-801-S25/
9845
MAY 2006
ETC
POWER LINE CDN FCC FCC-801-M3-32A/
9874
MAY 2006
ETC X
T2 EM-TEST
ATT6/75/
1001-40 N/A X
COAXIAL CABLE SUNCITY CABLE14/
#14-1M
AUG. 2006
SRT X
COAXIAL CABLE SUNCITY CABLE05/
#5-5M
AUG. 2006
SRT X
COAXIAL CABLE TIME LMR-400/
#2M
AUG. 2006
SRT X
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:29 of 38
Date: Jan. 24, 2007.
8.2 TEST PROCEDURE
According to IEC/EN 61000-4-6:2004
8.3 TEST SET-UP
(1) For CDN injection :
(2) For Clamp injection :
NOTE :
1. The EUT system was put on a wooden table with 0.1m height above ground.
2. For the actual test configuration, please refer to the photos of testing.
3. The distance between CDN(Clamp) and EUT was controlled between 0.1m and 0.3m.
4. The model no. of the CDN connected to EUT is FCC-801-M3-32A.
8.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
8.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
Power
A
m
p
lifier
CDN
T2
EUT
Auxiliary Equipment
SIGNAL
GENERATOR
Coaxial
Cable
SIGNAL
GENERATOR
Power
Amplifier
T2 Injection
Clamp
Monitoring Probe
EUT
Auxiliary Equipment
Receiver
Coaxial
Cable
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:30 of 38
Date: Jan. 24, 2007.
8.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Source voltage and frequency : 230 V/ 50 Hz, single phase
(2) Sweeping frequency : 150 kHz 80 MHz
(3) Test level : 3 V, the frequency step is 1%
(4) Modulation : AM 80%, 1 kHz
(5) Dwell time for each frequency : 3 sec
(6) Standard requirement : Criterion A
2. Performance criterion
(1) Criterion A : Normal performance during test
(2) Criterion B : Temporary degradation or loss of function
or performance which is self-recoverable
(3) Criterion C : Temporary degradation or loss of function
or performance which requires operator
intervention system reset
8.7 SUMMARY OF TEST RESULT
Temperature: 25°C Humidity: 87% RH
Tested Mode: N/A Tested By: Sunyou Chen
Tested Date: May 15, 2006
Test Result : Criterion A pass
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
FREQUENCY LEVEL MODULATION INJECTION
METHOD TEST RESULT
(CRITERION)
150kHz - 80MHz 3V 80% AM, 1 kHz M3 A
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:31 of 38
Date: Jan. 24, 2007.
9. POWER FREQUENCY MAGNETIC-FIELD TEST
9.1 TEST EQUIPMENT
EQUIPMENT /
FACILITIES MANUFACTURER MODEL # /
SERIAL #
DUE DATE OF CAL.
& CAL. CENTER
MAGNETIC FIELD
TESTER HAEFELY MAG 100.1/
080.015-04
DEC. 2006
SRT
MAGNETIC FIELD
COIL HAEFELY MAG 100.1/
080.015-04
DEC. 2006
SRT
MAGNETIC FIELD
METER F.W.BELL 4080/
19990416
MAY. 2006
ITRI
9.2 TEST PROCEDURE
According to IEC/EN 61000-4-8:1993+A1:2001
9.3 TEST SET-UP
NOTE :
1. The EUT system was put on a wooden table with 0.8m height above ground.
2. For the actual test configuration, please refer to the photos of testing
3. 1A/m = 12.56mG, 3A/m = 37.68mG, 10A/m = 125.6mG,
9.4 DESCRIPTION OF SUPPORT UNIT
Same as section 4.1.5 of this report.
EUT
Frequency Converter
Test Generator
Magnetic Coil
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:32 of 38
Date: Jan. 24, 2007.
9.5 EUT OPERATING CONDITION
Same as section 4.1.6 of this report.
9.6 TEST CONDITION / PERFORMANCE CRITERIA
1. Test condition
(1) Test axis : X, Y and Z axes
(2) Test time :5 min / each axis
(3) Field strength : 3 A/m
(4) Standard requirement : Criterion A
2. Performance criterion
(1) Criterion A : Normal performance during test
(2) Criterion B : Temporary degradation or loss of function
or performance which is self-recoverable
(3) Criterion C : Temporary degradation or loss of function
or performance which requires operator
intervention system reset
9.7 SUMMARY OF TEST RESULT
Temperature: 25°C Humidity: 87% RH
Tested Mode: N/A Tested By: Sunyou Chen
Frequency of Magnetic Field: 50Hz, 60Hz Tested Date: May 15, 2006
Test Result : Criterion A pass
NOTE:
Description of test observation:
A: There was no change compared with initial operation during the test.
ORIENTATION FIELD
STRENGTH TEST RESULT
(CRITERION)
X 3 A/m A
Y 3 A/m A
Z 3 A/m A
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:33 of 38
Date: Jan. 24, 2007.
10.1 PHOTOS OF TESTING
-Conducted Emission test
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:34 of 38
Date: Jan. 24, 2007.
- Radiated Emission test
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:35 of 38
Date: Jan. 24, 2007.
- Electrostatic discharge immunity test
- Electrical fast transient / burst immunity test
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:36 of 38
Date: Jan. 24, 2007.
- Radiated immunity test
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:37 of 38
Date: Jan. 24, 2007.
- Inducted RF fields (conducted susceptibility) test
- Power frequency magnetic-field test
Spectrum Research &
Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A07012402
Report No.:EMCA06051501-01
Page:38 of 38
Date: Jan. 24, 2007.
11. TERMS OF ABBREVIATION
AV. Average detection
AZ(°) Turn table azimuth
Correct. Correction
EL(m) Antenna height (meter)
EUT Equipment Under Test
Horiz. Horizontal direction
LISN Line Impedance Stabilization Network
NSA Normalized Site Attenuation
Q.P. Quasi-peak detection
SRT Lab Spectrum Research & Testing Laboratory, Inc.
Vert. Vertical direction