Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:2 of 38 Date: Jan. 24, 2007. Table of Contents 1. DOCUMENT POLICY AND TEST STATEMENT ................................................ 4 1.1 DOCUMENT POLICY .........................................................................................4 1.2 TEST STATEMENT.............................................................................................4 1.3 EUT MODIFICATION ..........................................................................................4 2. DESCRIPTION OF EUT AND TEST MODE....................................................... 5 2.1 GENERAL DESCRIPTION OF EUT ...................................................................5 2.2 DESCRIPTION OF EUT INTERNAL DEVICE.....................................................5 2.3 DESCRIPTION OF TEST MODE........................................................................5 3. DESCRIPTION OF APPLIED STANDARDS ...................................................... 6 4. EMISSION TEST................................................................................................ 7 4.1 CONDUCTED EMISSION TEST FOR MAIN PORT ...........................................7 4.1.1 CONDUCTED EMISSION LIMIT ........................................................................7 4.1.2 TEST EQUIPMENT ............................................................................................7 4.1.3 TEST SETUP......................................................................................................8 4.1.4 TEST PROCEDURE...........................................................................................8 4.1.5 DESCRIPTION OF SUPPORT UNIT..................................................................9 4.1.6 EUT OPERATING CONDITION..........................................................................9 4.1.7 TEST RESULT..................................................................................................10 4.2 RADIATED EMISSION TEST............................................................................ 11 4.2.1 RADIATED EMISSION LIMIT ........................................................................... 11 4.2.2 TEST EQUIPMENT .......................................................................................... 11 4.2.3 TEST SET-UP...................................................................................................12 4.2.4 TEST PROCEDURE.........................................................................................12 4.2.5 DESCRIPTION OF SUPPORT UNIT................................................................13 4.2.6 EUT OPERATING CONDITION........................................................................13 4.2.7 TEST RESULT..................................................................................................14 5. ELECTROSTATIC DISCHARGE IMMUNITY TEST ........................................... 15 5.1 TEST EQUIPMENT...........................................................................................15 5.2 TEST PROCEDURE .........................................................................................15 5.3 TEST SET-UP ...................................................................................................16 5.4 DESCRIPTION OF SUPPORT UNIT ................................................................17 5.5 EUT OPERATING CONDITION ........................................................................17 5.6 TEST CONDITION AND PERFORMANCE CRITERION ..................................17 5.7 SUMMARY OF TEST RESULT .........................................................................18 6. RADIATED IMMUNITY TEST ............................................................................ 19 6.1 TEST EQUIPMENT...........................................................................................19 6.2 TEST PROCEDURE .........................................................................................20 6.3 TEST SETUP ....................................................................................................21 6.4 DESCRIPTION OF SUPPORT UNIT ................................................................22 6.5 EUT OPERATING CONDITION ........................................................................22 6.6 TEST CONDITION / PERFORMANCE CRITERIA ...........................................22 6.7 TEST RESULT ..................................................................................................23 7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST .......................... 24 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:3 of 38 Date: Jan. 24, 2007. 7.1 TEST EQUIPMENT...........................................................................................24 7.2 TEST PROCEDURE .........................................................................................24 7.3 TEST SET-UP ...................................................................................................25 7.4 DESCRIPTION OF SUPPORT UNIT ................................................................25 7.5 EUT OPERATING CONDITION ........................................................................25 7.6 TEST CONDITION / PERFORMANCE CRITERIA ...........................................26 7.7 SUMMARY OF TEST RESULT .........................................................................27 8. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST ..................... 28 8.1 TEST EQUIPMENT...........................................................................................28 8.2 TEST PROCEDURE .........................................................................................29 8.3 TEST SET-UP ...................................................................................................29 8.4 DESCRIPTION OF SUPPORT UNIT ................................................................29 8.5 EUT OPERATING CONDITION ........................................................................29 8.6 TEST CONDITION / PERFORMANCE CRITERIA ...........................................30 8.7 SUMMARY OF TEST RESULT .........................................................................30 9. POWER FREQUENCY MAGNETIC-FIELD TEST............................................. 31 9.1 TEST EQUIPMENT...........................................................................................31 9.2 TEST PROCEDURE .........................................................................................31 9.3 TEST SET-UP ...................................................................................................31 9.4 DESCRIPTION OF SUPPORT UNIT ................................................................31 9.5 EUT OPERATING CONDITION ........................................................................32 9.6 TEST CONDITION / PERFORMANCE CRITERIA ...........................................32 9.7 SUMMARY OF TEST RESULT .........................................................................32 10.1 PHOTOS OF TESTING ................................................................................. 33 11. TERMS OF ABBREVIATION............................................................................ 38 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT 1. DOCUMENT POLICY AND TEST STATEMENT 1.1 DOCUMENT POLICY Reference No.: A07012402 Report No.:EMCA06051501-01 Page:4 of 38 Date: Jan. 24, 2007. - The report shall not be reproduced except in full, without the written approval of SRT Lab, Inc. - The report must not be used by the applicant to claim that the product is endorsed by NVLAP, TÜV, NEMKO and SRT. - The NVLAP logo applies only to the applicable standards specified in this report. 1.2 TEST STATEMENT - The test results in the report apply only to the unit tested by SRT Lab. - There was no deviation from the requirements of test standards during the test. - AC power source, 230 VAC/50 Hz, was used during the test. - The EN 61000-3-2 edition 2:2000(Harmonic test) and EN 61000-3-3:1995+A1:2001 (Flicker test) are not included in the scope of NVLAP logo usage. - The EN 61000-3-2 edition 2:2000(Harmonic test) and EN 61000-3-3:1995+A1:2001 (Flicker test) are included in the scope of TÜV, NEMKO and SRT logo usage. 1.3 EUT MODIFICATION - No modification in SRT Lab. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:5 of 38 Date: Jan. 24, 2007. 2. DESCRIPTION OF EUT AND TEST MODE 2.1 GENERAL DESCRIPTION OF EUT PRODUCT MODEL NO. POWER SUPPLY CABLE TYPE ExpressCard /34 EK-103,EK-104,EK-105,EK-108,EK-110,EK-202 DC from PC N/A Prototype NOTE : The EUT has eight model numbers as below on market. They are identical in all aspects except for the software. For more detailed information, please refer to the EUT’s specification or user’s manual provided by manufacturer. 2.2 DESCRIPTION OF EUT INTERNAL DEVICE DEVICE BRAND / MAKER MODEL # N/A NOTE : 1. The highest clock is 25MHz. 2. Frequency range to be measured. Radiated emission is 30 MHz to 1 GHz. 2.3 DESCRIPTION OF TEST MODE N/A (It is only applicable to more than one test mode.) REMARK Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:6 of 38 Date: Jan. 24, 2007. 3. DESCRIPTION OF APPLIED STANDARDS The EUT is a kind of ITE interface device and according to the specifications provided by the applicant, it must comply with the requirements of the following standards: EN 55022:1998+A1:2000+A2:2003, Class B EN 55024:1998+A1:2001+A2:2003 - IEC 61000-4-2:1995+A1:1998+A2:2001 - IEC 61000-4-3:1995+A1:1998+A2:2002 - IEC 61000-4-4:2004 - IEC 61000-4-6:2004 - IEC 61000-4-8:2001 But the standards of EN 61000-3-2, EN 61000-3-3, IEC 61000-4-5 and IEC 61000-4-11 were not measured, because the EUT’s power source is DC from PC. All tests have been performed and recorded as the above standards. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT 4. EMISSION TEST 4.1 CONDUCTED EMISSION TEST FOR MAIN PORT 4.1.1 CONDUCTED EMISSION LIMIT Class A (dBµV) FREQUENCY (MHz) Quasi-peak Average 0.15 - 0.5 79 66 Reference No.: A07012402 Report No.:EMCA06051501-01 Page:7 of 38 Date: Jan. 24, 2007. Class B (dBµV) Quasi-peak Average 66 - 56 56 - 46 0.5 - 5.0 73 60 56 46 5.0 - 30.0 73 60 60 50 NOTE: 1. The lower limit shall apply at the transition frequencies. 2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz. 4.1.2 TEST EQUIPMENT The following test equipment was used for the test: EQUIPMENT/ FACILITIES EMI TEST RECEIVER LISN (for EUT) LISN (for Peripheral) 50 ohm TERMINATOR COAXIAL CABLE ISOLATION TRANSFORMER FILTER SPECIFICATIONS MANUFACTURER 9 kHz TO 30 MHz ROHDE & SCHWARZ 50 µH, 50 ohm FCC 50 µH, 50 ohm FCC 50 ohm HP 5m SUNCITY N/A APC 2 LINE, 30A FIL.COIL 2.3M (H) x 2.4M (W) 2.4M (H) x GROUND PLANE 2.4M (W) GROUND PLANE MODEL#/ SERIAL# ESHS30/ 826003/008 FCC-LISN-50-25-2 / 01017 FCC-LISN-50-25-2 / 01018 11593A/ 2 CABLE/#5-5M AFC-11015/ F102040016 FC-943/ 771 DUE DATE OF CAL. & CAL. CENTER AUG. 2006 ETC NOV. 2006 ETC OCT. 2006 ETC OCT. 2006 ETC JUL. 2006 SRT N/A N/A SRT N/A N/A SRT N/A N/A NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:8 of 38 Date: Jan. 24, 2007. 4.1.3 TEST SETUP EMI TEST Receiver To Utility Power Coaxial Cable Isolation Transformer Filter LISN EUT LISN Support Units NOTE: 1. The EUT was put on a wooden table with 0.8m height above ground plane, and 0.4m away from reference ground plane (> 2mx2m). 2. For the actual test configuration, please refer to the photos of testing. 3. The serial no. of the LISN connected to EUT is 01017. 4. The serial no. of the LISN connected to support units is 01018. 4.1.4 TEST PROCEDURE The EUT was tested according to the requirement of EN 55022:1998+A1:2000+A2:2003. The frequency spectrum from 0.15 MHz to 30 MHz was investigated. The LISN used was 50Ω/50µH as specified. All readings were quasi-peak and average values with 10 kHz resolution bandwidth of the test receiver. The EUT system was operated in all typical methods by users. Both lines of the power mains of EUT were measured and the cables connected to EUT and support units were moved to find the maximum emission levels for each frequency. First, find the margin or higher points at least 6 points by software, then use manual to find the maximum data. The procedure is referred on the test procedure of SRT LAB. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:9 of 38 Date: Jan. 24, 2007. 4.1.5 DESCRIPTION OF SUPPORT UNIT The EUT was configured by the requirement of EN 55022:1998+A1:2000+A2:2003. All interface ports were connected to the appropriate support units via specific cables. The support units and cables are listed below. NO DEVICE BRAND MODEL # AS-T650- CABLE 1 PC ACER 1.8m unshielded power cord 2 MONITOR SAMSUNG 3 SATA HDD VANTEC 4 PRINTER EPSON 5 MODEM ACEEX 6 KEYBOARD IBM SK-8820 1.5m unshielded data cable 7 MOUSE IBM MU29J 1.5m unshielded data cable 1.5m unshielded power cord 1.2m shielded data cable 3.0m unshielded power cord NEXSTAR.3 1.0m unshielded data cable 1.5m unshielded power cord STYLUS C20SX 1.5m shielded data cable 1.8m unshielded DC power cable DM-1414 1.5m shielded data cable PG17IS NOTE: For the actual test configuration, please refer to the photos of testing. 4.1.6 EUT OPERATING CONDITION 1. Under Windows XP ran “EMITEST” and “XCOPY” programs. 2. EUT sent "H" pattern or accessed the following peripherals directly: - Color Monitor - RS232 - Keyboard - Mouse - Printer - FDD - HDD 3. XCOPY :loop XCOPY C:\test E:\/s/y Go to loop Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:10 of 38 Date: Jan. 24, 2007. 4.1.7 TEST RESULT Temperature: 25°C Humidity: 87%RH Ferquency Range: 0.15 – 30 MHz Tested Mode: N/A Receiver Detector: Q.P. and AV. Tested By: Sunyou Chen Tested Date: May 15, 2006 Power Line Measured : Line Correct. Reading Value Emission Level Limit Factor (dBµV) (dBµV) (dBµV) (dB) Q.P. AV. Q.P. AV. Q.P. AV. 0.477 0.25 41.20 40.89 41.45 41.14 56.39 46.39 Q.P. -14.94 AV. -5.25 0.480 0.25 41.02 40.47 41.27 40.72 56.34 46.34 -15.07 -5.62 0.682 0.22 35.72 32.18 35.94 32.40 56.00 46.00 -20.06 -13.60 1.230 0.14 32.92 31.65 33.06 31.79 56.00 46.00 -22.94 -14.21 2.804 0.18 31.20 26.68 31.38 26.86 56.00 46.00 -24.62 -19.14 9.628 0.23 33.46 29.93 33.69 30.16 60.00 50.00 -26.31 -19.84 Freq. (MHz) Margin (dB) Power Line Measured : Neutral Correct. Reading Value Emission Level Limit Factor (dBµV) (dBµV) (dBµV) (dB) Q.P. AV. Q.P. AV. Q.P. AV. 0.477 0.25 45.26 45.21 45.51 45.46 56.39 46.39 Q.P. -10.88 AV. -0.93 0.480 0.25 45.04 44.91 45.29 45.16 56.34 46.34 -11.05 -1.18 0.682 0.22 38.52 35.26 38.74 35.48 56.00 46.00 -17.26 -10.52 1.438 0.15 37.44 35.15 37.59 35.30 56.00 46.00 -18.41 -10.70 2.734 0.17 37.68 32.11 37.85 32.28 56.00 46.00 -18.15 -13.72 8.126 0.23 36.70 33.78 36.93 34.01 60.00 50.00 -23.07 -15.99 Freq. (MHz) Margin (dB) NOTE : 1. Measurement uncertainty is +/-1.32dB 2. Emission level = Reading value + Correction factor 3. Correction Factor = Cable loss + Insertion loss of LISN 4. Margin value = Emission level - Limit 5. The emission of other frequencies were very low against the limit. 6. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 4.2 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:11 of 38 Date: Jan. 24, 2007. RADIATED EMISSION TEST 4.2.1 RADIATED EMISSION LIMIT EN 55022:1998+A1:2000+A2:2003 limits of radiated emission measurement for frequency below 1000 MHz Class A (at 10m) Class B (at 10m) dBµV/m dBµV/m 30 – 230 40 30 230 - 1000 47 37 FREQUENCY (MHz) NOTE: 1. The lower limit shall apply at the transition frequencies. 2. Emission level (dBµV/m) = 20 log Emission level (µV/m). 4.2.2 TEST EQUIPMENT The following test equipment was used during the radiated emission test: EQUIPMENT/ FACILITIES EMI TEST RECEIVER BI-LOG ANTENNA SPECIFICATIONS MANUFACTURER MODEL#/ SERIAL# DUE DATE OF CAL. & CAL. CENTER 9 kHz TO 2.75 GHz 25 MHz TO 2 GHz 3 – 10 M MEASUREMENT ROHDE & SCHWARZ ESCS30/ 830245/012 OCT. 2006 ETC EMCO 3143/ 9509-1141 SRT SRT-1 COAXIAL CABLE 25M SUNCITY OCT. 2006 SRT DEC. 2006 SRT JUN. 2006 SRT FILTER 2 LINE, 30A FIL.COIL FREQUENCY CONVERTER N/A APC OATS J400-25M-2NP/ #153-25M FC-943/ 869 AFC-2KBB/ F100030031 N/A AUG. 2006 SRT NOTE: 1. The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. 2. The Open Area Test Site (SRT-1) is registered by FCC with No. 90957 and VCCI with No. R-1081. 3. The Open Area Test Site (SRT-2) is registered by FCC with No. 98458 and VCCI with No. R-1168. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:12 of 38 Date: Jan. 24, 2007. 4.2.3 TEST SET-UP Turn Table 1m – 4m EUT Coaxial Power Cable 0.8 m Cable 3/10m Filter To Utility Power Ground Plane EMI Receiver NOTE: 1. The EUT system was put on a wooden table with 0.8m heights above a ground plane. 2. For the actual test configuration, please refer to the photos of testing. 4.2.4 TEST PROCEDURE The EUT was tested according to the requirement of EN 55022:1998+A1:2000+A2:2003. The measurements were made at an open area test site with 10 meter measurement distance. The frequency spectrum measured from 30 MHz to 1 GHz. All readings were quasi-peak values with 120 kHz resolution bandwidth of the test receiver. The EUT system was operated in all typical methods by users. The cables connected to EUT and support units were moved to find the maximum emission levels for each frequency. First, find the margin or higher points at least 6 points by software, then use manual to find the maximum data. The procedure is referred on the test procedure of SRT LAB. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT 4.2.5 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 4.2.6 EUT OPERATING CONDITION Same as section 4.1.6 of this report. Reference No.: A07012402 Report No.:EMCA06051501-01 Page:13 of 38 Date: Jan. 24, 2007. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:14 of 38 Date: Jan. 24, 2007. 4.2.7 TEST RESULT Temperature: 25 °C Humidity: 87 %RH Ferquency Range: 0.15 – 30 MHz Tested Mode: N/A Receiver Detector: Q.P. and AV. Tested By: Sunyou Chen Tested Date: May 05, 2006 Antenna Polarization: Horizontal Frequency Cable Antenna Reading Emission Limit Margin (dBµV/m) (dB) 45.55 45.20 44.49 45.27 38.68 37.06 0.17 39.56 2.804 0.18 11.268 0.23 AZ(°) EL(m) 56.39 46.39 -10.84 44.74 56.34 46.34 -11.07 38.82 37.20 56.00 46.00 -17.18 36.90 39.73 37.07 56.00 46.00 -16.27 36.08 33.18 36.26 33.36 56.00 46.00 -19.74 35.94 30.25 36.17 30.48 60.00 50.00 -23.83 Limit Margin (dBµV/m) (dB) AZ(°) EL(m) Loss Factor Data Level (dB) (dB) (dBµV) (dBµV/m) 0.477 0.25 45.30 44.95 0.480 0.25 45.02 1.162 0.14 2.665 (MHz) Antenna Polarization:Vertical Frequency Cable Antenna Reading Emission Loss Factor Data Level (dB) (dB) (dBµV) (dBµV/m) 0.477 0.25 45.50 44.91 45.75 45.16 56.39 46.39 -10.64 0.480 0.25 45.30 44.49 45.55 44.74 56.34 46.34 -10.79 1.162 0.14 39.06 37.14 39.20 37.28 56.00 46.00 -16.80 2.665 0.17 39.72 36.74 39.89 36.91 56.00 46.00 -16.11 8.471 0.23 37.74 31.97 37.97 32.20 60.00 50.00 -22.03 9.222 0.23 38.54 34.89 38.77 35.12 60.00 50.00 -21.23 (MHz) NOTE : 1. Measurement uncertainty is +/-2dB. 2. "*": Measurement does not apply for this frequency. 3. Emissiom Level = Reading Value + Ant. Factor + Cable Loss. 4. The field strength of other emission frequencies were very low against the limit. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 5. 5.1 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:15 of 38 Date: Jan. 24, 2007. ELECTROSTATIC DISCHARGE IMMUNITY TEST TEST EQUIPMENT EQUIPMENT / FACILITIES MANUFACTURER ESD SIMULATOR NOISEKEN HCP (1.6M x 0.8M) SRT VCP (0.5M x 0.5M) SRT GROUND PLANE (3.4M x 2.4M) SRT MODEL # / SERIAL # ESS-100L(A)/TC-815P/ 8099C02238/7099C02 WITH TWO 470k OHM CABLE WITH TWO 470k OHM CABLE DUE DATE OF CAL. & CAL. CENTER OCT. 2006 ETC N/A N/A N/A N/A NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. 5.2 TEST PROCEDURE According to IEC/EN 61000-4-2:1995+A1:1998+A2:2001 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 5.3 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:16 of 38 Date: Jan. 24, 2007. TEST SET-UP ESD Gun Vertical Coupling Plane 10 cm 470kΩ EUT System Insulating Support Wooden Table Horizontal Coupling Plane 470kΩ Return Cable Ground Reference Plane NOTE : 1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT. 2. For the actual test configuration, please refer to the photos of testing. 3. A distance of 1m minimum was provided between EUT and walls / other metallic structure. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 5.4 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:17 of 38 Date: Jan. 24, 2007. DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 5.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. 5.6 TEST CONDITION AND PERFORMANCE CRITERION 1. Test condition (1) R-C Network (2) Test level: Air Discharge Contact discharge HCP discharge : VCP discharge : (3) Discharge mode (4) Discharge period (5) Discharge polarity (6) Number of discharge 2. Standard requirement 3. Performance criterion (1) Criterion A (2) Criterion B (3) Criterion C : 330 Ω, 150 pF : ±2kV, ±4kV, ±8kV : ±2kV, ±4kV ±2kV, ±4kV ±2kV, ±4kV : Single discharge : at least 1 s : Positive and Negative : Minimum 50 times at each test point of contact discharge and at least 200 times of discharge to EUT in total. Minium 10 times at each test area of air discharge selected. : Criterion B : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable : Temporary degradation or loss of function or performance which requires operator intervention system reset Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 5.7 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:18 of 38 Date: Jan. 24, 2007. SUMMARY OF TEST RESULT Temperature: 23°C Humidity: 50% RH Tested Mode: N/A Tested By: Sunyou Chen Atmospheric Air Pressure: 101.2kPa Tested Date: May 15, 2006 Test Result: Criterion B pass SEVERITY LEVEL COUPLING MODE & TEST OBSERVATION AIR DISCHARGE CONTACT DISCHARGE HCP VCP ±2kV A B A A ±4kV A B A A ±8kV A NR NR NR NOTE: Description of test observation: A: There was no change compared with initial operation during the test. B: EUT was delayed when copied data during the test. NR: No requirement Description of test points: 1. Connector 2. LED. 3. Enclosure of EUT. 4. HCP. 5. VCP. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 6. 6.1 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:19 of 38 Date: Jan. 24, 2007. RADIATED IMMUNITY TEST TEST EQUIPMENT EQUIPMENT / FACILITIES SIGNAL GENERATOR MODEL # / SERIAL # MANUFACTURER DUE DATE OF CAL. & CAL. CENTER 8648D/ 3847M00637 MAY. 2006 AGLIENT DUAL DIRECTIONAL A.R. COUPLER ISOTROPIC “E” A.R. FIELD PROBE CBL6141A / 4181 FP2000/ 28499 100W1000M1/ 19509 50S1G4A/ 308703 DC7420/ 308626 FP4080 KIT/ 308105 POWER SENSOR BOONTON 51011(SE)/ 32966 POWER SENSOR BOONTON 51011(CE)/ 32964 OCT. 2006 SRT DEC. 2006 ETC MAY 2006 ETC MAY 2006 A.R. MAY. 2006 ETC MAY. 2006 A.R. DEC. 2006 ETC DEC. 2006 ETC NOV. 2006 ETC. OCT. 2006 SRT ANTENNA FIELD SENSOR POWER AMPLIFIER AMPLIFIER HP SCHAFFNER CHASE AMPLIFIER RESEARCH AMPLIFIER RESEARCH A.R. DUAL DIRECTIONAL A.R. COUPLER ANECHOIC SRT CHAMBER V/M MONITOR A.R. MONITOR SHIN CCD TOPVIEW ABSORBER ETS COAXIAL CABLE COAXIAL CABLE SUNCITY SUNCITY DC6080/ 310289 A05/ SRT005 FM2000/ 15970 SI-609/ 905130 N/A/ 95113762 N/A N/A N/A N/A N/A LMR400/ 0.5M AUG. 2006 SRT J400-12M-NP MAY. 2006 SRT NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 6.2 TEST REPORT TEST PROCEDURE According to IEC/EN 61000-4-3:2002+A1:2002 Reference No.: A07012402 Report No.:EMCA06051501-01 Page:20 of 38 Date: Jan. 24, 2007. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 6.3 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:21 of 38 Date: Jan. 24, 2007. TEST SETUP Absorber Sensor EUT CCD 1.5m Absorber 0.8 m Wooden table Coaxial Cable 3m Power V/M Signal Amplifier Optical Fiber Monitor Monitor Generator NOTE : 1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT. 2. For the actual test configuration, please refer to the photos of testing. 1.1m door balun to Absorber/Tile Ant. 2.75m Absorber Location 1.5m 2.2m 1.85m chamber (7m x 3m x 3m) 0.24m Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 6.4 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:22 of 38 Date: Jan. 24, 2007. DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 6.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. 6.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Source voltage and frequency : 230V/50Hz, single phase (2) Sweeping frequency : 80MHz – 1 GHz (3) Test level : 3V/m, the frequncy step is 1% (4) The four sides of EUT are tested : front, rear, left, right (5) Modulation : 80%AM, 1kHz Dwell time for each frequency is 3 sec. (6) Antenna Polarization : Horizontal and Vertical (7) Standard requirement : Criterion A 2. Performance criterion (1) Criterion A (2) Criterion B (3) Criterion C : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable. : Temporary degradation or loss of function or performance which requires operator intervention system reset. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 6.7 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:23 of 38 Date: Jan. 24, 2007. TEST RESULT Temperature: Tested Mode: 23°C N/A Humidity: Tested By: Tested Date: 85% RH Sunyou Chen May 15, 2006 Test Result : Criterion A pass MODULATION DIRECTION TEST RESULT (CRITERION) H V FREQUENCY LEVEL 80MHz - 1GHz 3V/m 80%AM, 1kHz FRONT A A 80MHz - 1GHz 3V/m 80%AM, 1kHz REAR A A 80MHz - 1GHz 3V/m 80%AM, 1kHz LEFT A A 80MHz - 1GHz 3V/m 80%AM, 1kHz RIGHT A A NOTE: Description of test observation: A: There was no change compared with initial operation during the test. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 7. 7.1 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:24 of 38 Date: Jan. 24, 2007. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST TEST EQUIPMENT EQUIPMENT / FACILITIES MODEL # / SERIAL # MANUFACTURER DUE DATE OF CAL & CAL CENTER EFT GENERATOR HAEFELY PEFT-JUNIOR / 583-333-122 MAY. 2006 ETC CLAMP HAEFELY TRENCH / 080421-12 N/A GROUND PLANE 2M x 3M SRT N/A N/A 7.2 TEST PROCEDURE According to IEC/EN 61000-4-4:1995+A1:2001+A2:2001 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 7.3 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:25 of 38 Date: Jan. 24, 2007. TEST SET-UP Power Auxiliary EUT Equipment Clamp Auxiliary Equipment EFT Wave Generator I/O and communication ports Load EUT EFT Wave Power Cable Generator Auxiliary Equipment Power supply ports NOTE : 1. The EUT system was put on a wooden table with 0.8m height for table top EUT and 0.1m for floor-standing EUT above ground reference plane. 2. For the actual test configuration, please refer to the photos of testing. 3. The minimum distance between the EUT and all other conductive structure was more than 0.5m. 4. The minimum distance between the coupling plates of the coupling clamps (if used) and all over conductive structures, except the ground plane beneath the coupling clamp and beneath the EUT was more than 0.5m. 5. The power cable connecting EUT was controlled under 1m. 7.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 7.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 7.6 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:26 of 38 Date: Jan. 24, 2007. TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Source voltage and frequency (2) Pulse risetime and duration (3) Pulse repetition (4) Polarity (5) Burst duration and period (6) Test duration (7) Time between test (8) Severity levels (9) Standard requirement 2. Performance criterion (1) Criterion A (2) Criterion B (3) Criterion C : 230V/50Hz, single phase : 5ns / 50ns : 5kHz : Positive Polarization and Negative Polarization : 15ms / 300ms : 61sec each line : 10Sec : Power Line ±1kV Signal/Control Line ±0.5kV : Criterion B : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable. : Temporary degradation or loss of function or performance which requires operator intervention system reset. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 7.7 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:27 of 38 Date: Jan. 24, 2007. SUMMARY OF TEST RESULT Temperature: 25 °C Humidity: 87% RH Tested Mode: N/A Tested By: Sunyou Chen Atmospheric Air Pressure: 101.2 kPa Tested Date: May 15, 2006 Test Result : Criterion B pass Voltage 1kV Polarity Test Result + - L1 B B L2 B B GND B B Signal/Control Line N/A N/A NOTE: Description of test observation: A: There was no change compared with initial operation during the test. B: EUT was delayed when copied data during the test. N/A: Not applicable, as the signal/control line used in typical is less than 3 m. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 8. 8.1 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:28 of 38 Date: Jan. 24, 2007. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST TEST EQUIPMENT EQUIPMENT / FACILITIES MANUFACTURER EM INJECTION CLAMP FCC POWER LINE CDN FCC POWER LINE CDN FCC SIGNAL LINE CDN FCC SIGNAL LINE CDN MODEL # / SERIAL # FINAL DUE DATE OF CAL. TEST BE & CAL. CENTER USED F-203I-23mm/ 110 MAY 2006 ETC FCC-801-M5-32A/ 9812 FCC-801-M1-32A/ 9820 FCC-801-T2/ 9830 MAY 2006 ETC MAY 2006 ETC MAY 2006 ETC FCC FCC-801-T6/ 9832 MAY 2006 ETC SIGNAL LINE CDN FCC FCC-801-T4/ 9831 AUG. 2006 ETC POWER LINE CDN FCC FCC-801-M2-32A/ 9840 OCT. 2006 ETC SIGNAL GENERATOR R&S SMY01/ 841104/019 MAY. 2006 ETC X POWER AMPLIFIER A.R. 150A100A/ 19553 NOV. 2006 ETC X DUAL DIRECTION COULPER A.R. DC2600/ 25893 OCT. 2006 ETC X POWER METER BOONON 4232A/ 105302 NOV. 2006 ETC X POWER SENSOR BOONON 51011-EMC/31181 NOV. 2006 ETC X POWER SENSOR BOONON 51011-EMC/31745 NOV. 2006 ETC X SIGNAL LINE CDN FCC FCC-801-S25/ 9845 MAY 2006 ETC POWER LINE CDN FCC MAY 2006 ETC X T2 EM-TEST FCC-801-M3-32A/ 9874 ATT6/75/ 1001-40 N/A X COAXIAL CABLE SUNCITY COAXIAL CABLE SUNCITY COAXIAL CABLE TIME CABLE14/ #14-1M CABLE05/ #5-5M LMR-400/ #2M AUG. 2006 SRT AUG. 2006 SRT AUG. 2006 SRT X X X Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 8.2 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:29 of 38 Date: Jan. 24, 2007. TEST PROCEDURE According to IEC/EN 61000-4-6:2004 8.3 TEST SET-UP (1) For CDN injection : EUT Coaxial SIGNAL Cable GENERATOR Power T2 CDN Amplifier Auxiliary Equipment (2) For Clamp injection : EUT Monitoring Probe Coaxial SIGNAL GENERATOR Cable Power Amplifier T2 Injection Receiver Clamp Auxiliary Equipment NOTE : 1. The EUT system was put on a wooden table with 0.1m height above ground. 2. For the actual test configuration, please refer to the photos of testing. 3. The distance between CDN(Clamp) and EUT was controlled between 0.1m and 0.3m. 4. The model no. of the CDN connected to EUT is FCC-801-M3-32A. 8.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 8.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 8.6 TEST REPORT TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Source voltage and frequency (2) Sweeping frequency (3) Test level (4) Modulation (5) Dwell time for each frequency (6) Standard requirement 2. Performance criterion (1) Criterion A (2) Criterion B : 230 V/ 50 Hz, single phase : 150 kHz – 80 MHz : 3 V, the frequency step is 1% : AM 80%, 1 kHz : 3 sec : Criterion A : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable : Temporary degradation or loss of function or performance which requires operator intervention system reset (3) Criterion C 8.7 Reference No.: A07012402 Report No.:EMCA06051501-01 Page:30 of 38 Date: Jan. 24, 2007. SUMMARY OF TEST RESULT Temperature: 25°C Humidity: 87% RH Tested Mode: N/A Tested By: Sunyou Chen Tested Date: May 15, 2006 Test Result : Criterion A pass FREQUENCY LEVEL 150kHz - 80MHz 3V MODULATION 80% AM, 1 kHz INJECTION METHOD TEST RESULT (CRITERION) M3 A NOTE: Description of test observation: A: There was no change compared with initial operation during the test. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 9. 9.1 TEST REPORT POWER FREQUENCY MAGNETIC-FIELD TEST TEST EQUIPMENT EQUIPMENT / FACILITIES MAGNETIC FIELD TESTER MAGNETIC FIELD COIL HAEFELY MAGNETIC FIELD METER F.W.BELL 9.2 Reference No.: A07012402 Report No.:EMCA06051501-01 Page:31 of 38 Date: Jan. 24, 2007. MANUFACTURER HAEFELY MODEL # / SERIAL # MAG 100.1/ 080.015-04 MAG 100.1/ 080.015-04 DUE DATE OF CAL. & CAL. CENTER DEC. 2006 SRT DEC. 2006 SRT 4080/ 19990416 MAY. 2006 ITRI TEST PROCEDURE According to IEC/EN 61000-4-8:1993+A1:2001 9.3 TEST SET-UP Magnetic Coil EUT Test Generator Frequency Converter NOTE : 1. The EUT system was put on a wooden table with 0.8m height above ground. 2. For the actual test configuration, please refer to the photos of testing 3. 1A/m = 12.56mG, 3A/m = 37.68mG, 10A/m = 125.6mG, 9.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 9.5 TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:32 of 38 Date: Jan. 24, 2007. EUT OPERATING CONDITION Same as section 4.1.6 of this report. 9.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Test axis (2) Test time (3) Field strength (4) Standard requirement : X, Y and Z axes : 5 min / each axis : 3 A/m : Criterion A 2. Performance criterion (1) Criterion A (2) Criterion B : Normal performance during test : Temporary degradation or loss of function or performance which is self-recoverable : Temporary degradation or loss of function or performance which requires operator intervention system reset (3) Criterion C 9.7 SUMMARY OF TEST RESULT Temperature: 25°C Humidity: 87% RH Tested Mode: N/A Tested By: Sunyou Chen Frequency of Magnetic Field: ▓50Hz, □60Hz Tested Date: May 15, 2006 Test Result : Criterion A pass ORIENTATION FIELD STRENGTH TEST RESULT (CRITERION) X 3 A/m A Y 3 A/m A Z 3 A/m A NOTE: Description of test observation: A: There was no change compared with initial operation during the test. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 10.1 PHOTOS OF TESTING -Conducted Emission test TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:33 of 38 Date: Jan. 24, 2007. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. - Radiated Emission test TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:34 of 38 Date: Jan. 24, 2007. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT - Electrostatic discharge immunity test - Electrical fast transient / burst immunity test Reference No.: A07012402 Report No.:EMCA06051501-01 Page:35 of 38 Date: Jan. 24, 2007. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. - Radiated immunity test TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:36 of 38 Date: Jan. 24, 2007. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT - Inducted RF fields (conducted susceptibility) test - Power frequency magnetic-field test Reference No.: A07012402 Report No.:EMCA06051501-01 Page:37 of 38 Date: Jan. 24, 2007. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 11. TEST REPORT Reference No.: A07012402 Report No.:EMCA06051501-01 Page:38 of 38 Date: Jan. 24, 2007. TERMS OF ABBREVIATION AV. Average detection AZ(°) Turn table azimuth Correct. Correction EL(m) Antenna height (meter) EUT Equipment Under Test Horiz. Horizontal direction LISN Line Impedance Stabilization Network NSA Normalized Site Attenuation Q.P. Quasi-peak detection SRT Lab Spectrum Research & Testing Laboratory, Inc. Vert. Vertical direction
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Print high-res Page Count : 38 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:feaca906-d97a-4ed5-a4b2-6899a576cfba Producer : Acrobat Distiller 6.0 (Windows) Modify Date : 2007:01:25 11:53:12+08:00 Create Date : 2007:01:24 15:31:03+08:00 Creator Tool : PScript5.dll Version 5.2 Metadata Date : 2007:01:25 11:53:12+08:00 Document ID : uuid:a012480b-f577-4c6e-bd19-7fedf4fd234d Format : application/pdf Title : Microsoft Word - EMCA06051501.doc Creator : Administrator Author : AdministratorEXIF Metadata provided by EXIF.tools