Shenzhen Certification Technology Service Co., Ltd.

FCC TEST REPORT
For
SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD
USB HUB

Model No.

: UE-U035

Prepared for : SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD
Address
: Floor 5, Building A, Wentao Industrial Park, Tangtou, Shiyan, Shenzhen,
China.

Prepared By : Shenzhen Certification Technology Service Co., Ltd.

Report Number : STE120822139
Date of Test
: August 21-22, 2012
Date of Report : August 22, 2012

Report No.: STE120822139

Page 1 of 23

Shenzhen Certification Technology Service Co., Ltd.

TABLE OF CONTENTS
Description

Page

Test Report Declaration ………………………………………...…….……...…3
1. SUMMARY OF STANDARDS AND RESULTS ..................................................................... 4
1.1. Description of Standards and Results.................................................................................. 4
2. GENERAL INFORMATION ..................................................................................................... 5
2.1. Description of Device (EUT) .............................................................................................. 5
2.2. Tested Supporting System Details....................................................................................... 6
2.3. Block Diagram of connection between EUT and simulators .............................................. 6
2.4. Test Facility ......................................................................................................................... 7
2.5. Measurement Uncertainty ................................................................................................... 7
3. POWER LINE CONDUCTED EMISSION TEST................................................................... 8
3.1. Test Equipment.................................................................................................................... 8
3.2. Block Diagram of Test Setup .............................................................................................. 8
3.3. Power Line Conducted Emission Test Limits ..................................................................... 8
3.4. Configuration of EUT on Test............................................................................................. 9
3.5. Operating Condition of EUT ............................................................................................... 9
3.6. Test Procedure ..................................................................................................................... 9
3.7. Conducted Disturbance at Mains Terminals Test Results................................................... 9
4. RADIATED EMISSION TEST ................................................................................................ 12
4.1. Test Equipment.................................................................................................................. 12
4.2. Block Diagram of Test Setup ............................................................................................ 12
4.3. Radiated Emission Limit ................................................................................................... 13
4.4. EUT Configuration on Test ............................................................................................... 13
4.5. Operating Condition of EUT ............................................................................................. 14
4.6. Test Procedure ................................................................................................................... 14
4.7. Radiated Disturbance Test Results.................................................................................... 15
5. PHOTOGRAPH......................................................................................................................... 18
5.1. Photos of Radiated Emission Test (In Anechoic Chamber).............................................. 18
5.2. Photos of Power Line Conducted Emission Test .............................................................. 19
6. PHOTOS OF THE EUT............................................................................................................ 20

Report No.: STE120822139

Page 2 of 23

Shenzhen Certification Technology Service Co., Ltd.

TEST REPORT VERIFICATION
Applicant

:SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD

Manufacturer

:SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD

EUT Description : USB HUB
(A) Model No.
(B)Trademark
(C) Serial No.
(D) Power Supply
(E) Test Voltage

:
:
:
:
:

UE-U035
N/A
N/A
DC 5V
DC 5V From PC AC 120V/60Hz

Measurement Standard Used:
FCC Rules and Regulations Part 15 Subpart B Class B 2011, ANSI C63.4-2003
The device described above is tested by Shenzhen Certification Technology Service Co., Ltd. to
determine the maximum emission levels emanating from the device. The maximum emission
levels are compared to the FCC Part 15 Subpart B Class B limits both conducted and radiated
emissions. The test results are contained in this test report and Shenzhen Certification Technology
Service Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these
tests.
After the test, our opinion is that EUT compliance with the requirement of the above standards.
This report applies to above tested sample only. This report shall not be reproduced in parts
without written approval of Shenzhen Certification Technology Service Co., Ltd.
Date of Test :

August 21-22, 2012

Prepared by :

Report of date:

August 22, 2012

Reviewer by :
Nina Wang/ Assistant

Report No.: STE120822139

Simple Guan / Assistant Manager

Page 3 of 23

Shenzhen Certification Technology Service Co., Ltd.

1. SUMMARY OF STANDARDS AND RESULTS
1.1.Description of Standards and Results
The EUT have been tested according to the applicable standards as referenced below.
EMISSION
Description of Test Item

Standard

Limits

Results

Power Line Conducted
Emission Test

FCC Part 15: 2011
ANSI C63.4: 2003

Class B

PASS

Radiated Emission Test

FCC Part 15: 2011
ANSI C63.4: 2003

Class B

PASS

Report No.: STE120822139

Page 4 of 23

Shenzhen Certification Technology Service Co., Ltd.

2. GENERAL INFORMATION
2.1. Description of Device (EUT)
Description

: USB HUB

Model Number : UE-U035
Trademark

: N/A

Applicant
Address

: SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD
: Floor 5, Building A, Wentao Industrial Park, Tangtou, Shiyan,
Shenzhen, China.

Manufacturer
Address

: SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD
: Floor 5, Building A, Wentao Industrial Park, Tangtou, Shiyan,
Shenzhen, China.

Sample Type

: Series production

Report No.: STE120822139

Page 5 of 23

Shenzhen Certification Technology Service Co., Ltd.

2.2.Tested Supporting System Details
No.

Description

Manufacturer

Model

Serial Number

1.

Personal Computer

ACER

ASPIRE
M1830

PTSF90C00305005CAC300
0

2.

Monitor

ACER

G205HV

SNID:10306738385

3.

USB Keyboard

ACER

SK-9625

KBUSB1580500037E0100

4.

USB Mouse

ACER

MS.11200.0
14

M-UAY-ACR2

5.

Printer

HP

HP1020

CNCJ410726

6.

USB Flash Disk

N/A

N/A

N/A

Signal Cable Description of the above Support Units
No.

Port Name

Cable

Length

Shielded
(Yes or No)

Detachable
(Yes or No)

1

N/A

N/A

N/A

N/A

N/A

2.3. Block Diagram of connection between EUT and simulators

Monitor

USB Flash Disk

EUT

USB Keyboard

PC

Printer

USB Mouse

※ EUT: USB HUB

Report No.: STE120822139

Page 6 of 23

Shenzhen Certification Technology Service Co., Ltd.

2.4. Test Facility
JAN 13, 2012 File on Federal Communication Commission
Registration Number:197647
October 11, 2011 Certificated by IC
Registration Number: 8528B
August 4, 2010 Certificated by CNAS
Registration Number: L4656
NOV. 17, 2008 Accredited by SGS
Registration Number: SWL-017
NOV. 18, 2008 Accredited by NEMKO
Registration Number: 17025

2.5. Measurement Uncertainty
(95% confidence levels, k=2)
Test Item

Uncertainty

Uncertainty for Conduction emission test

2.50dB
3.04 dB (Distance: 3m Polarize: V)

Uncertainty for Radiation Emission test
3.02 dB (Distance: 3m Polarize: H)
Uncertainty for Radiation Emission test
(1GHz-18GHz)
Uncertainty for test site temperature and
humidity

Report No.: STE120822139

3.56 dB (Distance: 3m Polarize: V)
3.84 dB (Distance: 3m Polarize: H)
0.6℃
3%

Page 7 of 23

Shenzhen Certification Technology Service Co., Ltd.

3. POWER LINE CONDUCTED EMISSION TEST
3.1. Test Equipment
Item Equipment
Manufacturer
1. Test Receiver Rohde &
Schwarz
2. L.I.S.N.#1
Schwarzbeck
3. L.I.S.N.#2
Kyoritsu
4. Terminator
Hubersuhner
5. RF Cable
Schwarzbeck

Model No.
ESCI

Serial No.
100843

NSLK8126
KNW-242C
50Ω
9111505/200

6.

CX-210

8126466
Oct. 17, 11
8-1920-1
Oct. 17, 11
No. 1
Oct. 17, 11
5995-12-161- Apr 17, 12
6890#
N/A
Apr 17, 12

VTSD9516F

9618

7.

Coaxial
Schwarzbeck
Switch
Pulse Limiter Schwarzbeck

Last Cal. Cal. Interval
Oct. 17, 11 1 Year
1 Year
1 Year
1 Year
1/2 Year
1/2 Year

Oct. 17, 11 1 Year

3.2. Block Diagram of Test Setup

EUT

PC System

Peripheral

80cm

>80cm
80cm
50Ω Impedance

Receiver

LISN

LISN

3.3. Power Line Conducted Emission Test Limits
Maximum RF Line Voltage
Frequency
Quasi-Peak Level
Average Level
dB(μV)
dB(μV)
150kHz ~ 500kHz
66 ~ 56*
56 ~ 46*
500kHz ~ 5MHz
56
46
5MHz ~ 30MHz
60
50
Notes: 1. Emission level=Read level+LISN factor-Preamp factor+Cable loss
2* Decreasing linearly with logarithm of frequency.
3. The lower limit shall apply at the transition frequencies.

Report No.: STE120822139

Page 8 of 23

Shenzhen Certification Technology Service Co., Ltd.

3.4. Configuration of EUT on Test
The following equipment are installed on Power Line Conducted Emission Test to meet the
commission requirement and operating regulations in a manner which tends to maximize its
emission characteristics in a normal application.
Support Equipments : As Tested Supporting System Detail, in Section 2.2.

3.5. Operating Condition of EUT
3.5.1. Setup the EUT and simulator as shown as Section 3.2.
3.5.2. Turn on the power of all equipment.
3.5.3. Let the EUT work in test mode (Data Transmitting) and measure it.

3.6. Test Procedure
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT Power
connected to the power mains through a line impedance stabilization network (L.I.S.N. 1#). The
other peripheral devices power cord connected to the power mains through a line impedance
stabilization network (L.I.S.N. #2), this provided a 50-ohm coupling impedance for the EUT
(Please refer to the block diagram of the test setup and photographs). Both sides of power line
were checked for maximum conducted interference. In order to find the maximum emission, the
relative positions of equipments and all of the interface cables were changed according to ANSI
C63.4-2003 on conducted Emission test.
The bandwidth of test receiver (R&S TEST RECEIVER ESCI) is set at 10kHz.
The frequency range from 150kHz to 30MHz is checked. The test result are reported on Section
3.7.

3.7. Conducted Disturbance at Mains Terminals Test Results
PASS. (All emissions not reported below are too low against the prescribed limits.)
The EUT with the following test mode was tested and read QP values and average values, the
test results are listed in next pages.
Temperature: 25℃

Humidity: 55%

The details of test mode is as follows:
No.

Test Mode

1

Data Transmitting

Report No.: STE120822139

Page 9 of 23

Shenzhen Certification Technology Service Co., Ltd.

Report No.: STE120822139

Page 10 of 23

Shenzhen Certification Technology Service Co., Ltd.

Report No.: STE120822139

Page 11 of 23

Shenzhen Certification Technology Service Co., Ltd.

4. RADIATED EMISSION TEST
4.1. Test Equipment
Item
1
2
3
4
5
6

Equipment
Test Receiver
Amplifier
Bilog
Antenna
RF Cable
RF Cable
RF Cable

Manufacturer
Rohde&Schwarz
Schwarzbeck
Schwarzbeck

Model No.
ESCI
BBV9743
VULB 9168

Schwarzbeck
Schwarzbeck
Schwarzbeck

AK9515E
AK9515E
AK9515E

Serial No.
Last Cal.
101165
Oct. 17, 11
9743-019
Oct. 17, 11
VULB9168-43 Feb.12, 12
8
95891-2m
Oct. 17, 11
95891-11m
Oct. 17, 11
95891-0.5m
Oct. 17, 11

Cal. Interval
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year

For frequency range 1GHz~5GHz (At Semi Anechoic Chamber)
Cal.
Interval
Spectrum Analyzer Agilent
E4446A
US44300459 Oct. 17, 11 1 Year
Horn Antenna
EMCO
BBV9743
9743-019
Oct. 17, 11 1 Year
SCHWARZBEC
Oct. 17, 11
Amplifier
Schwarzbeck
N/A
1 Year
K
RF Cable
Hubersuhner SUCOFLEX102 28620/2
Oct. 17, 11 1 Year
RF Cable
Hubersuhner SUCOFLEX102 271471/4
Oct. 17, 11 1 Year
RF Cable
Hubersuhner SUCOFLEX102 29086/2
Oct. 17, 11 1 Year

Item Equipment
1
2
3
4
5
6

Manufacturer Model No.

Serial No.

Last Cal.

4.2. Block Diagram of Test Setup
4.2.1. In Semi Anechoic Chamber (3m) Test Setup Diagram for 30MHz~1000MHz

Semi-anechoic Chamber
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS

3m
EUT and
Support System

TURN TABLE
1.5m(L)*1.0m(W)*0.8m(H)

(WOOD)

Receiver

Report No.: STE120822139

Page 12 of 23

Shenzhen Certification Technology Service Co., Ltd.
4.2.2. In Semi Anechoic Chamber (3m) Test Setup Diagram for 1-5GHz

Semi-anechoic Chamber
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS

3m
EUT and
Support System

1.5m(L)*1.0m(W)*0.8m(H)

TURN TABLE
(FIBRE GLASS)

Receiver

4.3. Radiated Emission Limit
Frequency
Distance
Field Strengths Limits
MHz
(Meters)
dB(μV)/m
30 ~ 88
3
40.0
88 ~ 216
3
43.5
216 ~ 960
3
46.0
960 ~ 1000
3
54.0
1000 ~ 5000
3
74(Peak) 54(Average)
Remark: (1) Emission level = Read level+Antenna Factor-Preamp Factor +Cable Loss
(2) The smaller limit shall apply at the cross point between two frequency bands.
(3) Distance is the distance in meters between the measuring instrument, antenna and the
closest point of any part of the device or system.

4.4. EUT Configuration on Test
The following equipment are installed on Radiated Emission Test to meet the commission
requirements and operating regulations in a manner that tends to maximize its emission
characteristics in normal application.
4.4.1. Support Equipments : As Tested Supporting System Detail, in Section 2.2.

Report No.: STE120822139

Page 13 of 23

Shenzhen Certification Technology Service Co., Ltd.

4.5. Operating Condition of EUT
4.5.1.Setup the EUT as shown in Section 4.2.
4.5.2.Turn on the power of all equipment.
4.5.3.Let the EUT work in test mode (Data Transmitting) and test it.

4.6. Test Procedure
The EUT was placed on a non-metallic table, 80 cm above the ground plane inside a
semi-anechoic chamber. An antenna was located 3m from the EUT on an adjustable mast. A
pre-scan was first performed in order to find prominent radiated emissions. For final emissions
measurements at each frequency of interest, the EUT were rotated and the antenna height was
varied between 1m and 4m in order to maximize the emission. Measurements in both horizontal
and vertical polarities were made and the data was recorded. In order to find the maximum
emission, the relative positions of equipments and all of the interface cables were changed
according to ANSI C63.4-2003 on Radiated Emission test.
The bandwidth setting on the test receiver (ROHDE&SCHWARZ TEST RECEIVER ESCI) is
120 kHz.
The resolution bandwidth of the Agilent Spectrum Analyzer E4446A was set at 1MHz. (For
above 1GHz)
The frequency range from 30MHz to 1000MHz was pre-scanned with a peak detector and all
final readings of measurement from Test Receiver are Quasi-Peak values.
The frequency range from 1GHz to 5GHz was checked with peak and average detector,
measurement distance is 3m in 3m chamber.
Finally, selected operating situations at Anechoic Chamber measurement, all the test results are
listed in section 4.7.

Report No.: STE120822139

Page 14 of 23

Shenzhen Certification Technology Service Co., Ltd.

4.7. Radiated Disturbance Test Results
PASS. (All emissions not reported below are too low against the prescribed limits.)
For frequency range 30MHz~1000MHz
The EUT with the following test mode was tested and read QP values and average values, the
test results are listed in next pages.
Temperature: 25℃

Humidity: 55%

The details of test mode is as follows:
No.

Test Mode

1

Data Transmitting

For frequency range 1GHz~5GHz
The highest frequency of the internal sources of the EUT is less than 108 MHz, the measurement
shall only be made up to 1 GHz. So the frequency rang 1GHz-5GHz radiation test not
applicable.

Report No.: STE120822139

Page 15 of 23

Shenzhen Certification Technology Service Co., Ltd.

Report No.: STE120822139

Page 16 of 23

Shenzhen Certification Technology Service Co., Ltd.

Report No.: STE120822139

Page 17 of 23

Shenzhen Certification Technology Service Co., Ltd.

5. PHOTOGRAPH
5.1.Photos of Radiated Emission Test (In Anechoic Chamber)

Report No.: STE120822139

Page 18 of 23

Shenzhen Certification Technology Service Co., Ltd.

5.2.Photos of Power Line Conducted Emission Test

Report No.: STE120822139

Page 19 of 23

Shenzhen Certification Technology Service Co., Ltd.

6. PHOTOS OF THE EUT

Front View

Rear View

Report No.: STE120822139

Page 20 of 23

Shenzhen Certification Technology Service Co., Ltd.

Top View

Bottom View

Report No.: STE120822139

Page 21 of 23

Shenzhen Certification Technology Service Co., Ltd.

Left View

Right View

Report No.: STE120822139

Page 22 of 23

Shenzhen Certification Technology Service Co., Ltd.

Inside view

Inside view
-------THE END OF REPORT-------

Report No.: STE120822139

Page 23 of 23



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2012:08:24 10:19:27+08:00
Create Date                     : 2012:08:24 10:17:43+08:00
Metadata Date                   : 2012:08:24 10:19:27+08:00
Format                          : application/pdf
Title                           : Microsoft Word - STE120822139.doc
Creator                         : Administrator
Document ID                     : uuid:3c8630d2-9152-4385-953a-f144b346e638
Instance ID                     : uuid:c723e762-a760-495c-b874-159137f35948
Page Count                      : 23
Author                          : Administrator
EXIF Metadata provided by EXIF.tools

Navigation menu