Shenzhen Certification Technology Service Co., Ltd. FCC TEST REPORT For SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD USB HUB Model No. : UE-U035 Prepared for : SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD Address : Floor 5, Building A, Wentao Industrial Park, Tangtou, Shiyan, Shenzhen, China. Prepared By : Shenzhen Certification Technology Service Co., Ltd. Report Number : STE120822139 Date of Test : August 21-22, 2012 Date of Report : August 22, 2012 Report No.: STE120822139 Page 1 of 23 Shenzhen Certification Technology Service Co., Ltd. TABLE OF CONTENTS Description Page Test Report Declaration ………………………………………...…….……...…3 1. SUMMARY OF STANDARDS AND RESULTS ..................................................................... 4 1.1. Description of Standards and Results.................................................................................. 4 2. GENERAL INFORMATION ..................................................................................................... 5 2.1. Description of Device (EUT) .............................................................................................. 5 2.2. Tested Supporting System Details....................................................................................... 6 2.3. Block Diagram of connection between EUT and simulators .............................................. 6 2.4. Test Facility ......................................................................................................................... 7 2.5. Measurement Uncertainty ................................................................................................... 7 3. POWER LINE CONDUCTED EMISSION TEST................................................................... 8 3.1. Test Equipment.................................................................................................................... 8 3.2. Block Diagram of Test Setup .............................................................................................. 8 3.3. Power Line Conducted Emission Test Limits ..................................................................... 8 3.4. Configuration of EUT on Test............................................................................................. 9 3.5. Operating Condition of EUT ............................................................................................... 9 3.6. Test Procedure ..................................................................................................................... 9 3.7. Conducted Disturbance at Mains Terminals Test Results................................................... 9 4. RADIATED EMISSION TEST ................................................................................................ 12 4.1. Test Equipment.................................................................................................................. 12 4.2. Block Diagram of Test Setup ............................................................................................ 12 4.3. Radiated Emission Limit ................................................................................................... 13 4.4. EUT Configuration on Test ............................................................................................... 13 4.5. Operating Condition of EUT ............................................................................................. 14 4.6. Test Procedure ................................................................................................................... 14 4.7. Radiated Disturbance Test Results.................................................................................... 15 5. PHOTOGRAPH......................................................................................................................... 18 5.1. Photos of Radiated Emission Test (In Anechoic Chamber).............................................. 18 5.2. Photos of Power Line Conducted Emission Test .............................................................. 19 6. PHOTOS OF THE EUT............................................................................................................ 20 Report No.: STE120822139 Page 2 of 23 Shenzhen Certification Technology Service Co., Ltd. TEST REPORT VERIFICATION Applicant :SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD Manufacturer :SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD EUT Description : USB HUB (A) Model No. (B)Trademark (C) Serial No. (D) Power Supply (E) Test Voltage : : : : : UE-U035 N/A N/A DC 5V DC 5V From PC AC 120V/60Hz Measurement Standard Used: FCC Rules and Regulations Part 15 Subpart B Class B 2011, ANSI C63.4-2003 The device described above is tested by Shenzhen Certification Technology Service Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart B Class B limits both conducted and radiated emissions. The test results are contained in this test report and Shenzhen Certification Technology Service Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests. After the test, our opinion is that EUT compliance with the requirement of the above standards. This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Shenzhen Certification Technology Service Co., Ltd. Date of Test : August 21-22, 2012 Prepared by : Report of date: August 22, 2012 Reviewer by : Nina Wang/ Assistant Report No.: STE120822139 Simple Guan / Assistant Manager Page 3 of 23 Shenzhen Certification Technology Service Co., Ltd. 1. SUMMARY OF STANDARDS AND RESULTS 1.1.Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below. EMISSION Description of Test Item Standard Limits Results Power Line Conducted Emission Test FCC Part 15: 2011 ANSI C63.4: 2003 Class B PASS Radiated Emission Test FCC Part 15: 2011 ANSI C63.4: 2003 Class B PASS Report No.: STE120822139 Page 4 of 23 Shenzhen Certification Technology Service Co., Ltd. 2. GENERAL INFORMATION 2.1. Description of Device (EUT) Description : USB HUB Model Number : UE-U035 Trademark : N/A Applicant Address : SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD : Floor 5, Building A, Wentao Industrial Park, Tangtou, Shiyan, Shenzhen, China. Manufacturer Address : SHENZHEN UNIVERSAL ELECTRON TECHNOLOGY CO., LTD : Floor 5, Building A, Wentao Industrial Park, Tangtou, Shiyan, Shenzhen, China. Sample Type : Series production Report No.: STE120822139 Page 5 of 23 Shenzhen Certification Technology Service Co., Ltd. 2.2.Tested Supporting System Details No. Description Manufacturer Model Serial Number 1. Personal Computer ACER ASPIRE M1830 PTSF90C00305005CAC300 0 2. Monitor ACER G205HV SNID:10306738385 3. USB Keyboard ACER SK-9625 KBUSB1580500037E0100 4. USB Mouse ACER MS.11200.0 14 M-UAY-ACR2 5. Printer HP HP1020 CNCJ410726 6. USB Flash Disk N/A N/A N/A Signal Cable Description of the above Support Units No. Port Name Cable Length Shielded (Yes or No) Detachable (Yes or No) 1 N/A N/A N/A N/A N/A 2.3. Block Diagram of connection between EUT and simulators Monitor USB Flash Disk EUT USB Keyboard PC Printer USB Mouse ※ EUT: USB HUB Report No.: STE120822139 Page 6 of 23 Shenzhen Certification Technology Service Co., Ltd. 2.4. Test Facility JAN 13, 2012 File on Federal Communication Commission Registration Number:197647 October 11, 2011 Certificated by IC Registration Number: 8528B August 4, 2010 Certificated by CNAS Registration Number: L4656 NOV. 17, 2008 Accredited by SGS Registration Number: SWL-017 NOV. 18, 2008 Accredited by NEMKO Registration Number: 17025 2.5. Measurement Uncertainty (95% confidence levels, k=2) Test Item Uncertainty Uncertainty for Conduction emission test 2.50dB 3.04 dB (Distance: 3m Polarize: V) Uncertainty for Radiation Emission test 3.02 dB (Distance: 3m Polarize: H) Uncertainty for Radiation Emission test (1GHz-18GHz) Uncertainty for test site temperature and humidity Report No.: STE120822139 3.56 dB (Distance: 3m Polarize: V) 3.84 dB (Distance: 3m Polarize: H) 0.6℃ 3% Page 7 of 23 Shenzhen Certification Technology Service Co., Ltd. 3. POWER LINE CONDUCTED EMISSION TEST 3.1. Test Equipment Item Equipment Manufacturer 1. Test Receiver Rohde & Schwarz 2. L.I.S.N.#1 Schwarzbeck 3. L.I.S.N.#2 Kyoritsu 4. Terminator Hubersuhner 5. RF Cable Schwarzbeck Model No. ESCI Serial No. 100843 NSLK8126 KNW-242C 50Ω 9111505/200 6. CX-210 8126466 Oct. 17, 11 8-1920-1 Oct. 17, 11 No. 1 Oct. 17, 11 5995-12-161- Apr 17, 12 6890# N/A Apr 17, 12 VTSD9516F 9618 7. Coaxial Schwarzbeck Switch Pulse Limiter Schwarzbeck Last Cal. Cal. Interval Oct. 17, 11 1 Year 1 Year 1 Year 1 Year 1/2 Year 1/2 Year Oct. 17, 11 1 Year 3.2. Block Diagram of Test Setup EUT PC System Peripheral 80cm >80cm 80cm 50Ω Impedance Receiver LISN LISN 3.3. Power Line Conducted Emission Test Limits Maximum RF Line Voltage Frequency Quasi-Peak Level Average Level dB(μV) dB(μV) 150kHz ~ 500kHz 66 ~ 56* 56 ~ 46* 500kHz ~ 5MHz 56 46 5MHz ~ 30MHz 60 50 Notes: 1. Emission level=Read level+LISN factor-Preamp factor+Cable loss 2* Decreasing linearly with logarithm of frequency. 3. The lower limit shall apply at the transition frequencies. Report No.: STE120822139 Page 8 of 23 Shenzhen Certification Technology Service Co., Ltd. 3.4. Configuration of EUT on Test The following equipment are installed on Power Line Conducted Emission Test to meet the commission requirement and operating regulations in a manner which tends to maximize its emission characteristics in a normal application. Support Equipments : As Tested Supporting System Detail, in Section 2.2. 3.5. Operating Condition of EUT 3.5.1. Setup the EUT and simulator as shown as Section 3.2. 3.5.2. Turn on the power of all equipment. 3.5.3. Let the EUT work in test mode (Data Transmitting) and measure it. 3.6. Test Procedure The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT Power connected to the power mains through a line impedance stabilization network (L.I.S.N. 1#). The other peripheral devices power cord connected to the power mains through a line impedance stabilization network (L.I.S.N. #2), this provided a 50-ohm coupling impedance for the EUT (Please refer to the block diagram of the test setup and photographs). Both sides of power line were checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipments and all of the interface cables were changed according to ANSI C63.4-2003 on conducted Emission test. The bandwidth of test receiver (R&S TEST RECEIVER ESCI) is set at 10kHz. The frequency range from 150kHz to 30MHz is checked. The test result are reported on Section 3.7. 3.7. Conducted Disturbance at Mains Terminals Test Results PASS. (All emissions not reported below are too low against the prescribed limits.) The EUT with the following test mode was tested and read QP values and average values, the test results are listed in next pages. Temperature: 25℃ Humidity: 55% The details of test mode is as follows: No. Test Mode 1 Data Transmitting Report No.: STE120822139 Page 9 of 23 Shenzhen Certification Technology Service Co., Ltd. Report No.: STE120822139 Page 10 of 23 Shenzhen Certification Technology Service Co., Ltd. Report No.: STE120822139 Page 11 of 23 Shenzhen Certification Technology Service Co., Ltd. 4. RADIATED EMISSION TEST 4.1. Test Equipment Item 1 2 3 4 5 6 Equipment Test Receiver Amplifier Bilog Antenna RF Cable RF Cable RF Cable Manufacturer Rohde&Schwarz Schwarzbeck Schwarzbeck Model No. ESCI BBV9743 VULB 9168 Schwarzbeck Schwarzbeck Schwarzbeck AK9515E AK9515E AK9515E Serial No. Last Cal. 101165 Oct. 17, 11 9743-019 Oct. 17, 11 VULB9168-43 Feb.12, 12 8 95891-2m Oct. 17, 11 95891-11m Oct. 17, 11 95891-0.5m Oct. 17, 11 Cal. Interval 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year For frequency range 1GHz~5GHz (At Semi Anechoic Chamber) Cal. Interval Spectrum Analyzer Agilent E4446A US44300459 Oct. 17, 11 1 Year Horn Antenna EMCO BBV9743 9743-019 Oct. 17, 11 1 Year SCHWARZBEC Oct. 17, 11 Amplifier Schwarzbeck N/A 1 Year K RF Cable Hubersuhner SUCOFLEX102 28620/2 Oct. 17, 11 1 Year RF Cable Hubersuhner SUCOFLEX102 271471/4 Oct. 17, 11 1 Year RF Cable Hubersuhner SUCOFLEX102 29086/2 Oct. 17, 11 1 Year Item Equipment 1 2 3 4 5 6 Manufacturer Model No. Serial No. Last Cal. 4.2. Block Diagram of Test Setup 4.2.1. In Semi Anechoic Chamber (3m) Test Setup Diagram for 30MHz~1000MHz Semi-anechoic Chamber ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS 3m EUT and Support System TURN TABLE 1.5m(L)*1.0m(W)*0.8m(H) (WOOD) Receiver Report No.: STE120822139 Page 12 of 23 Shenzhen Certification Technology Service Co., Ltd. 4.2.2. In Semi Anechoic Chamber (3m) Test Setup Diagram for 1-5GHz Semi-anechoic Chamber ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS 3m EUT and Support System 1.5m(L)*1.0m(W)*0.8m(H) TURN TABLE (FIBRE GLASS) Receiver 4.3. Radiated Emission Limit Frequency Distance Field Strengths Limits MHz (Meters) dB(μV)/m 30 ~ 88 3 40.0 88 ~ 216 3 43.5 216 ~ 960 3 46.0 960 ~ 1000 3 54.0 1000 ~ 5000 3 74(Peak) 54(Average) Remark: (1) Emission level = Read level+Antenna Factor-Preamp Factor +Cable Loss (2) The smaller limit shall apply at the cross point between two frequency bands. (3) Distance is the distance in meters between the measuring instrument, antenna and the closest point of any part of the device or system. 4.4. EUT Configuration on Test The following equipment are installed on Radiated Emission Test to meet the commission requirements and operating regulations in a manner that tends to maximize its emission characteristics in normal application. 4.4.1. Support Equipments : As Tested Supporting System Detail, in Section 2.2. Report No.: STE120822139 Page 13 of 23 Shenzhen Certification Technology Service Co., Ltd. 4.5. Operating Condition of EUT 4.5.1.Setup the EUT as shown in Section 4.2. 4.5.2.Turn on the power of all equipment. 4.5.3.Let the EUT work in test mode (Data Transmitting) and test it. 4.6. Test Procedure The EUT was placed on a non-metallic table, 80 cm above the ground plane inside a semi-anechoic chamber. An antenna was located 3m from the EUT on an adjustable mast. A pre-scan was first performed in order to find prominent radiated emissions. For final emissions measurements at each frequency of interest, the EUT were rotated and the antenna height was varied between 1m and 4m in order to maximize the emission. Measurements in both horizontal and vertical polarities were made and the data was recorded. In order to find the maximum emission, the relative positions of equipments and all of the interface cables were changed according to ANSI C63.4-2003 on Radiated Emission test. The bandwidth setting on the test receiver (ROHDE&SCHWARZ TEST RECEIVER ESCI) is 120 kHz. The resolution bandwidth of the Agilent Spectrum Analyzer E4446A was set at 1MHz. (For above 1GHz) The frequency range from 30MHz to 1000MHz was pre-scanned with a peak detector and all final readings of measurement from Test Receiver are Quasi-Peak values. The frequency range from 1GHz to 5GHz was checked with peak and average detector, measurement distance is 3m in 3m chamber. Finally, selected operating situations at Anechoic Chamber measurement, all the test results are listed in section 4.7. Report No.: STE120822139 Page 14 of 23 Shenzhen Certification Technology Service Co., Ltd. 4.7. Radiated Disturbance Test Results PASS. (All emissions not reported below are too low against the prescribed limits.) For frequency range 30MHz~1000MHz The EUT with the following test mode was tested and read QP values and average values, the test results are listed in next pages. Temperature: 25℃ Humidity: 55% The details of test mode is as follows: No. Test Mode 1 Data Transmitting For frequency range 1GHz~5GHz The highest frequency of the internal sources of the EUT is less than 108 MHz, the measurement shall only be made up to 1 GHz. So the frequency rang 1GHz-5GHz radiation test not applicable. Report No.: STE120822139 Page 15 of 23 Shenzhen Certification Technology Service Co., Ltd. Report No.: STE120822139 Page 16 of 23 Shenzhen Certification Technology Service Co., Ltd. Report No.: STE120822139 Page 17 of 23 Shenzhen Certification Technology Service Co., Ltd. 5. PHOTOGRAPH 5.1.Photos of Radiated Emission Test (In Anechoic Chamber) Report No.: STE120822139 Page 18 of 23 Shenzhen Certification Technology Service Co., Ltd. 5.2.Photos of Power Line Conducted Emission Test Report No.: STE120822139 Page 19 of 23 Shenzhen Certification Technology Service Co., Ltd. 6. PHOTOS OF THE EUT Front View Rear View Report No.: STE120822139 Page 20 of 23 Shenzhen Certification Technology Service Co., Ltd. Top View Bottom View Report No.: STE120822139 Page 21 of 23 Shenzhen Certification Technology Service Co., Ltd. Left View Right View Report No.: STE120822139 Page 22 of 23 Shenzhen Certification Technology Service Co., Ltd. Inside view Inside view -------THE END OF REPORT------- Report No.: STE120822139 Page 23 of 23
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2012:08:24 10:19:27+08:00 Create Date : 2012:08:24 10:17:43+08:00 Metadata Date : 2012:08:24 10:19:27+08:00 Format : application/pdf Title : Microsoft Word - STE120822139.doc Creator : Administrator Document ID : uuid:3c8630d2-9152-4385-953a-f144b346e638 Instance ID : uuid:c723e762-a760-495c-b874-159137f35948 Page Count : 23 Author : AdministratorEXIF Metadata provided by EXIF.tools