Catalog Surge Protection And Power Supply Units 2013 170209

2016-10-06

: Pdf 170209-Catalog 170209-Catalog B5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 296

DownloadCatalog Surge Protection And Power Supply Units 2013  170209-Catalog
Open PDF In BrowserView PDF
Surge Protection
and Power Supply Units
2013 / 2014

6

PCB connection technology and electronics housing
• PCB terminal blocks and plug-in connectors
• Electronics housing

Connection technology for field devices
• Plug-in connectors
• Cables and connectors

Modular terminal blocks
• Modular terminal blocks

Sensor/actuator cabling and industrial plug-in connectors
• Sensor/actuator cabling
• Cables and connectors
• Plug-in connectors

Marking systems, tools, and mounting material
• Marking and labeling
• Tools
• Installation and mounting material

Surge protection
and power supply units

Interface technology and switching devices
• Electronic switching devices and motor control
• Measurement and control technology • Monitoring
• Relay modules • System cabling for controllers

Control technology, I/O systems and automation infrastructure
• Ethernet networks • Functional safety • HMIs and industrial PCs • I/O systems
• Industrial lighting and signaling • Industrial communication technology
• Fieldbus components and systems • Wireless data communication
• Process infrastructure • Software • Controllers

Table of contents

Overview

2

The table of contents will help you find the right product more quickly

Lightning monitoring system

Surge protection and interference filters

5

11

Power supply units and UPS

159

Protective devices

251

Technical information

276

Index

290

Introduction
Product range overview
Lightning current measuring system

Surge protection for the power supply

LM-S

Type 1 lightning arrester
FLASHTRAB
POWERTRAB
VALVETRAB T1/T2

Page 8

Page 28
Page 32
Page 34

Type 1 + 2 lightning and surge arrester
combination
FLASHTRAB compact
Page 36

Type 2 surge arrester
VALVETRAB compact
VALVETRAB MS
Combination arrester

Page 40
Page 42
Page 52

Arrester for PV systems
Box solution for PV systems

Box solution for the
American market

Page 68

Set solutions

Type 3 device protection

Page 56

Building set

Page 65

Page 64
Page 66

Surge protection for measurement and control technology

Surge protection for information technology

DIN rail modules
PLUGTRAB
LINETRAB
TERMITRAB

For networks
For interfaces

Page 72
Page 90
Page 94

Special systems
LSA-PLUS modules

Page 100
Page 102

Surge protection for transceiver systems

For mobile phone networks
For video communication

2

PHOENIX CONTACT

Page 136
Page 140

For radio and television sets

Page 142

Page 114
Page 116

Telecommunications systems

EMC solutions

Testers

Mains interference filters with integrated
surge protection
Page 146
Interference filters
Page 148

CHECKMASTER
Test adapters

Page 126

Page 152
Page 152

Introduction
Product range overview
Power supply units

QUINT POWER

Page 166

TRIO POWER

Page 174

MINI POWER

Page 180

DC/DC converters

STEP POWER

Page 186

QUINT POWER, dip-coated

Page 194

Power storage for
QUINT UPS-IQ

Page 222

QUINT DC/DC converters
MINI DC/DC converter

UNO POWER

Page 184

Redundancy modules

Page 198
Page 202

QUINT ORING
TRIO DIODE
QUINT DIODE
STEP DIODE

Page 206
Page 208
Page 210
Page 210

UPS for the control cabinet

QUINT UPS-IQ

Page 218

UPS for 19" rack/tower

UPS devices

Page 244

UPS with integrated power storage
QUINT UPS
Page 230
QUINT BUFFER
Page 231
STEP UPS
Page 232

UPS with integrated power supply unit
TRIO UPS
Page 234
MINI UPS
Page 235

Protective devices

Battery modules
Accessories

Page 246
Page 248

CB device circuit breakers
Circuit breaker

Page 256
Page 263

For additional information, visit www.phoenixcontact.net/products

TCP thermal circuit breakers
Page 264
Fuse terminal blocks, see Catalog 3

PHOENIX CONTACT

3

4

PHOENIX CONTACT

LM-S lightning monitoring system
Lightning strikes are a particular hazard
for exposed structures such as offshore
wind parks, radio masts, leisure facilities or
high buildings.
The LM-S lightning current measuring system can detect, evaluate, and remotely
monitor lightning strikes in realtime. This
means that information about the actual
load on the system from lightning strikes is
available at all times. The findings obtained
regarding the load on a system enable optimized maintenance planning.

Lightning monitoring system
Introduction

6

LM-S
Sensor

8

Connecting cable

8

Evaluation unit

9

Optoelectronic module

9

PHOENIX CONTACT

5

Lightning current measuring system
Lightning current measuring system introduction

Lightning strikes cause devastating damage to buildings and systems. It is practically
impossible for employees to continuously
monitor exposed or large-scale systems,
which means that damage is detected too
late.

6

PHOENIX CONTACT

Detecting lightning with the lightning
monitoring system
The LM-S lightning monitoring system
supports continuous monitoring. Lightning
events are detected, evaluated, and remotely monitored via network access. This
means that information about the actual
load on the system from lightning strikes is
available at all times. The findings obtained
regarding the load on a system enable optimized maintenance planning.
The LM-S lightning current measuring system consists of the following components:
– Sensor
– Connecting cable
– O/E module
– Evaluation unit

Lightning current measuring system
Lightning current measuring system introduction

Faraday effect as a reliable measuring
method
The internal measuring principle of the
LM-S is based on the Faraday effect. Polarized light in a specific medium is rotated
through a magnetic field over a defined
length and measured.
The higher the amperage (i) generated by
a lightning strike the greater the magnetic
flux density (B) and, therefore, the rotation
of the polarized light.
The lightning monitoring system detects
this change in the light signal and uses this as
the basis for the corresponding measured
value results.

Detection and evaluation
The sensors are mounted on the lightning
arrester cables. They record the magnetic
field that occurs around the conductor due
to the lightning surge current. The measured result is transmitted via fiber optics to
the O/E module of the evaluation unit,
where the optical signal is converted into an
electrical signal. Based on the values obtained, the evaluation unit determines the
lightning characteristics with their typical
parameters, including, for example, the
maximum lightning current strength, lightning current rate of rise, charge, and energy.
These results can be forwarded to an available management system via the Ethernet
interface.

Remote monitoring in realtime
The evaluation unit can be easily integrated into standard network systems via the
RJ45 Ethernet interface. An internal web
server is used as the basis for accessing recorded data and configuring the system.
The web interface is opened via the Internet
browser of a PC connected to the system
using IP addressing.

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

7

Lightning current measuring system
LM-S
Sensor

– Optical lightning sensor for measuring
current strength of lightning surge currents
– Subsequent mounting is possible
– Rugged design
– Resistant to vibrations, temperature, and
humidity
– Good UV resistance
– Good oil resistance
Sensor
Technical data
Detectable values
Maximum current strength
FO interface
Connection method
General data
Ambient temperature (operation)
Ambient temperature (storage/transport)
Degree of protection

250 kA
SCRJ socket with push/pull connector, IP67
-30 °C ... 60 °C
-40 °C ... 85 °C
IP67

Ordering data
Description

Type

Order No.

LM-S-LS-H

2800616

Pcs. /
Pkt.

Sensor

Connecting cable

1

Notes:
The specified plug configuration (see ordering example) must be
used in order to use the connecting cable in the LM-S lightning
monitoring system. Recommended length: 10 to 200 m

– HCS cable for connecting LM-S sensors
to the O/E module
– Robust cable for use in harsh environments
– Good UV resistance
– Good oil resistance

Connecting cable for LM-S

Ordering example for LM-S connecting
cable with variable cable length:
Assembled connecting cable for the LM-S lightning monitoring system, with a metal push/pull plug-in connector, a B-FOC plug, and a
cable length of 10 m.

Technical data
General data
Ambient temperature (operation)
Ambient temperature (storage/transport)
Degree of protection

-40°C ... 70°C
-40°C ... 70°C
IP20 (B-FOC)/IP67 (PPCME)

Ordering data
Order No.
1408480 /
FOC-HCS-BFOC/1018B/PPCME /

Length [m]
Max. 200 m
10.0
Increments:
10.0 m ... 200 m = 1.0 m

8

PHOENIX CONTACT

Description

Type

Order No.

Connecting cable
Variable

FOC-HCS-BFOC/1018B/PPCME/…

1408480

Pcs. /
Pkt.

1

Lightning current measuring system
LM-S
Evaluation unit

– Complete module including O/E module
for connecting up to three LM-S sensors
– Evaluation and storage of amperage, current increase rate, charge, and specific energy
– Realtime analysis and exact time allocation
– Status and diagnostic indicators
– Communication via Ethernet
– Operation and configuration via web interface
– Mounting on a DIN rail

Evaluation unit with O/E module
Technical data
Supply voltage
Ethernet interfaces
Connection method
Transmission speed
FO interface
Interface
Number of ports
Sensor interfaces
Connection method
Remote indication contact
Connection method
Max. operating voltage
General data
Ambient temperature (operation)
Degree of protection

24 V DC ± 4 V
RJ45
10/100 Mbps
B-FOC (ST®)
3
Rack for plug-in I/O module
M12 D-coded
- / 60 V DC
-30 °C ... 60 °C
IP20

Ordering data
Description

Type

Order No.

LM-S-A/C-3S-ETH

2800618

Pcs. /
Pkt.

Evaluation unit with O/E module
1

Optoelectronic module

– O/E module replacement for evaluation
unit
– Connection of up to three LM-S sensors
– Status and diagnostic display via evaluation unit

O/E module
Technical data
FO interface
Interface
Number of ports
General data
Ambient temperature (operation)
Ambient temperature (storage/transport)
Degree of protection

B-FOC (ST®)
3
-40 °C ... 60 °C
-40 °C ... 85 °C
IP20

Ordering data
Description

Type

Order No.

LM-S-C-3LS

2800617

Pcs. /
Pkt.

Optoelectronic module

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1

9

10

PHOENIX CONTACT

Surge protection and interference filters
Damage caused by surge voltages
The number of electrical devices damaged
or destroyed by surge voltages is increasing
year on year. This can prove expensive in
terms of repairs and downtimes. In an industrial environment, the hazards are not
only restricted to systems and devices.
Building technology applications and even
residential buildings may be affected.
Interference voltages
Switching operations triggered mechanically or electronically generate pulse-like
and high-frequency interference voltages.
These voltages spread in an unimpeded
manner across the cable network. All the
devices within this cable network are affected. Data errors, uncontrolled functions, and
system crashes can result, with electronic
and data processing devices at particular
risk.

Selection guides and applications

12

Surge protection for the power supply

26

Type 1 lightning arresters

28

Type 1 + 2 lightning/surge arrester combinations

36

Type 2 surge arresters

40

Industry solutions

50

Type 2 combined solutions

52

Type 3 device protection

56

Renewable energy sources

64

Set solutions

65

Surge protection for measurement and control technology
DIN rail modules
- PLUGTRAB PT-IQ
- MCR-PLUGTRAB
- LINETRAB
- TERMITRAB
Special systems
- SURGETRAB
Modules for LSA-PLUS technology
- COMTRAB modular
- COMTRAB

70
72

100
102

Surge protection for information technology

112

Bus systems

114

Telecommunications

126

Surge protection for transceiver systems

134

Transceiver technology

136

TV and radio systems

140

Interference filters

144

Filters with type 3 surge protection

146

Filters

149

Test device for arresters

150

Approvals

154

PHOENIX CONTACT

11

Surge protection and interference filters
Selection guide and applications
General information on the application drawings below
– The example illustrations are intended to help you select the right surge protection. They make no claim to be complete with regard
to the prescribed safety measures.
– The illustrated connection diagrams do not replace standard-compliant planning of a protection concept by an electrical or lightning
protection specialist.
– The fixed electrical installation may only be accessed by trained specialist personnel.
– In order to ensure the correct and appropriate use of products, the relevant installation notes must be observed prior to installation
or startup.
– All information/notes can be downloaded under the relevant product documentation at www.phoenixcontact.net/products.

Distinguishing features of the protective devices for the power supply

Lightning protection zone transition
Without detailed calculation of the lightning surge current at
the installation location can be used at Lightning Protection
Level

Type 1

Type 1+2

Type 1/2

Type 2

Type 3

0-1

0-2

0-1/1-2

1-2

2-3

I - IV

I - IV

III - IV

Type 1 and type 2 combined in a single device
Can be used universally

Three-stage protection for the power supply, type 1 and type 2 installed separately + type 3

TN-S/TT
230/400 V AC
240/415 V AC

L1
L2
L3
N
PE

F2*

F1

PHOENIX CONTACT

F2*

F1

L1
L2
L3
N
PE

Type 1
FLT-CP-PLUS-3S-350

Type 2
VAL-CP-3S-350

Type 3
PT 4-PE/S-230AC/FM

2882640
Page 28

2859521
Page 40

2882459
Page 56

* F2 is not needed if F1  maximum backup fuse according to IEC

12

F2*

F1

Surge protection and interference filters
Selection guide and applications
Two-stage protection for the power supply, type 1/2 combination based on varistor + type 3

TN-S/TT
230/400 V AC
240/415 V AC

L1
L2
L3
N
PE

F1

F2*

F1

F2*

F2*
L1
L2
L3
N
PE

Type 1/2
VAL-MS-T1/T2 335/12.5/3+1-FM

Type 3
MNT-1 D

2800183
Page 34

2882200
Page 60

Three-stage protection for the power supply, type 1 and type 2 installed separately + type 3
F1

L1
L2
L3
N
PE

F2*

TN-S/TT
230/400 V AC
240/415 V AC

L1
L2
L3
N
PE

F2*

F1

F2*

F1

L1
L2
L3
N
PE

Type 1
FLT-CP-PLUS-3S-350

Type 2
VAL-CP-RCD-3S/40/0.3/SEL

Type 3
PRT-CD-AD1 + PRT-S-230/FM

2882640
Page 28

2808001
Page 52

2749673 + 2749686
Page 58

* F2 is not needed if F1  maximum backup fuse according to IEC

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

13

Surge protection and interference filters
Selection guide and applications
Three-stage protection for the power supply, type 1 and type 2 installed separately + type 3

TN-C-S
230/400 V AC
240/415 V AC

F2*

F2*

10

12

7

9

11

F2*

F1

F1

11

F1

L1
L2
L3

L1
L2
L3
N
PE

PEN

Type 1
FLT-CP-PLUS-3C-350

Type 2
VAL-CP-3S-350

Type 3
PT 2-PE/S-230AC/FM

2882653
Page 28

2859521
Page 40

2858357
Page 56

Two-stage protection for the power supply, type 1/2 combination based on varistor + type 3

TN-C-S
230/400 V AC
240/415 V AC

F2*

F2*

F2*
F1

F1
L1
L2
L3

L1
L2
L3
N
PE

PEN

Type 1/2
VAL-MS-T1/T2 335/12.5/3+0-FM

Type 3
MNT-1 D

2800188
Page 34

2882200
Page 60

* F2 is not needed if F1  maximum backup fuse according to IEC

14

PHOENIX CONTACT

Surge protection and interference filters
Selection guide and applications
Three-stage protection for the power supply, type 1 and type 2 combined in a single device + type 3

TN-C-S
230/400 V AC
240/415 V AC

F2*

F2*
F1

F1
L1
L2
L3

L1
L2
L3
N
PE

PEN

Type 1+2
FLT-CP-3C-350

Type 3
BT-1S-230AC/A

2859725
Page 36

2803409
Page 58

* F2 is not needed if F1  maximum backup fuse according to IEC

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

15

Surge protection and interference filters
Selection guide and applications
Two-stage protection for the power supply, type 1 and type 2 installed separately

TN-C
400/690 V AC
554/960 V AC

L1
L2
L3

F2*

F1

F1

F2*
L1
L2
L3

PEN

PEN

Type 1
PWT 100-800AC-FM

Type 2
VAL-MS 750/30/3+0-FM

2800531
Page 32

2920272
Page 51

* F2 is not needed if F1  maximum backup fuse according to IEC

16

PHOENIX CONTACT

Surge protection and interference filters
Selection guide and applications
Two-stage protection for the power supply, type 1 and type 2 installed separately

IT
500 V AC

L1
L2
L3

F2*

F1

F1

F2*
L1
L2
L3
PE

Type 1
PWT 100-800AC-FM

Type 2 **
VAL-MS 580/3+0-FM

2800531
Page 32

2920447
Page 42

Two-stage protection for the power supply, type 1 and type 2 installed separately

IT
690 V AC

L1
L2
L3

F2*

F1

F1

F2*
L1
L2
L3
PE

Type 1
PWT 100-800AC-FM

Type 2**
VAL-MS 750/30/3+0-FM

2800531
Page 32

2920272
Page 51

* F2 is not needed if F1  maximum backup fuse according to IEC
** Application only in IT systems supplied with a low voltage

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

17

Surge protection and interference filters
Selection guide and applications
Protection of a binary signal input with actuator circuit, floating reference potential

IN

2
4

10

11

12

6

7

8

2

3

9

10

4

5

11

12

6

1

7

8

2

3

9

10

4

5

11

12

6

Push-in connection

1

Plug-in

PLC

5

E.g.,
24 V switched

9

3

0V

8

7

1

24 V

OUT

1 x PT-IQ-PTB-PT +
2 x PT-IQ-4X1+F-24DC-PT

24 V

6

0V
L+
L-

1 x PT-IQ-PTB-UT +
2 x PT-IQ-4X1+F-24DC-UT

Optional screw connection

2801296 + 2801272
Page 74

2800768 + 2800983
Page 72

Protection of a binary signal input with actuator circuit, grounded reference potential

IN

7

8

9

10

24 V

6

0V
L+
L-

10

9

12

11

1 x PT-IQ-PTB-UT +
2 x PT-IQ-4X1-24DC-UT

PLC

8

7

Screw connection

12

11

Plug-in

12

11

E.g.,
24 V switched

10

9

0V

8

7

24 V

OUT

Optional push-in connection

1 x PT-IQ-PTB-PT +
2 x PT-IQ-4X1-24DC-PT

2800768 + 2800982
Page 72

2801296 + 2801271
Page 74

Protection of a binary signal input with actuator circuit, common grounded reference potential (negative pole)

IN

OUT

PLC

L+
L-

E.g.,
24 V switched

PE

One-piece

Screw connection

TT-2/2-M-24DC
2920722
Page 94

18

PHOENIX CONTACT

Optional
spring-cage connection

TT-ST-M-2/2-24DC
2858917
Page 96

Surge protection and interference filters
Selection guide and applications
Protection of a binary signal input with actuator circuit, common floating reference potential (negative pole)

IN

OUT

PLC

L+
L-

E.g.,
24 V switched

PE

One-piece

TT-ST-M-2/2-24DC
Spring-cage connection

2858917
Page 96

TT-2/2-M-24DC

Optional
screw connection

2920722
Page 94

Protection of a four-conductor measurement

IN

11
9
7

12

12

10

11

8

OUT

8

9

E.g., temperature
measurement

7

5

IN

10

OUT

I
U
U
I

PE

Power

Plug-in

PT 4-24DC-ST + PT 4-BE

PT 4-24DC-ST + PT 4-BE

2839240 + 2839402
Page 84

2839240 + 2839402
Page 84

Protection of a four-conductor measurement, for Ex and non-Ex applications

IN

OUT

IN

OUT

I
U
U
I

5

E.g., temperature
measurement

PE

Power

One-piece

LIT 4-24

LIT 4-24

2804678
Page 92

2804678
Page 92

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

19

Surge protection and interference filters
Selection guide and applications
Protection of an analog measurement

0(4) ... 20 mA
0 ... 10 V

Plug-in

1 x PT-IQ-PTB-PT +
2 x PT-IQ-1X2-24DC-PT

Push-in connection

Optional screw connection

1 x PT-IQ-PTB-UT +
2 x PT-IQ-1X2-24DC-UT

2801296 + 2801255
Page 74

2800768 + 2800976
Page 72

Protection of an analog measurement

IN

OUT

IN

OUT

PLC
PE
4...20 mA

0(4) ... 20 mA
0 ... 10 V

4...20 mA

One-piece

TT-2-PE-M-24DC
Screw connection

2920641
Page 94

TT-ST-2-PE-24DC

Optional
spring-cage connection

2858904
Page 96

Protection of an analog measurement, intrinsically safe circuits

OUT

IN

IN

OUT

PLC
PE
4...20 mA

0(4) ... 20 mA
0 ... 10 V

4...20 mA

One-piece

TT-ST-M-EX(I)-24DC
Spring-cage connection

20

PHOENIX CONTACT

2859424
Page 96

Optional
screw connection

TT-EX(I)-M-24DC
2803865
Page 94

Surge protection and interference filters
Selection guide and applications
Protection of an analog measurement, intrinsically safe circuits

0(4) ... 20 mA
0 ... 10 V

Plug-in

PT 2XEX(I)-24DC-ST + PT 2XEX(I)-BE

PT 2XEX(I)-24DC-ST + PT 2XEX(I)-BE

2838225 + 2839279
Page 87

2838225 + 2839279
Page 87

Protection of an analog measurement, intrinsically safe circuits

IN

OUT

PLC
4...20 mA

0(4) ... 20 mA
0 ... 10 V

One-piece

4...20 mA

PE

S-PT-EX-24DC

TT-ST-M-EX(I)- 24DC

2800034
Page 100

2859424
Page 96

Protection of an analog measurement, intrinsically safe circuits

0(4) ... 20 mA
0 ... 10 V

One-piece

S-PT-EX(I)-24DC

PT 2XEX(I)-24DC-ST + PT 2XEX(I)-BE

2880671
Page 100

2838225 + 2839279
Page 87

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

21

Surge protection and interference filters
Selection guide and applications
Protection of PROFIBUS DP

PT-IQ-PTB-UT + PT-IQ-5HF-12DC-UT

Optional

2800768 + 2800799
Page 78

PT 5-HF-12DC-ST +
PT 2X2-BE
2838775 + 2839208
Page 88

Protection of PROFIBUS PA

PT 2XEX(I)-24DC + PT 2XEX(I)-BE
2838225 + 2839279
Page 87

Protection of CAN bus/DeviceNet™

PT 5-HF-12DC-ST + PT 2X2-BE
2838775 + 2839208
Page 88

22

PHOENIX CONTACT

PT 2-PE/S-24AC/FM

PT 3-HF-12DC-ST +
PT 1X2-BE

2800457
Page 56

2858043 + 2856113
Page 88

Surge protection and interference filters
Selection guide and applications
Protection of an RS-485 interface

PT-IQ-PTB-PT + PT-IQ-5-HF-12DC-PT

PT 5-HF-12DC-ST +
PT 2X2-BE

Optional

2801296 + 2801293
Page 79

2838775 + 2839208
Page 88

Protection of an Ethernet interface (including PoE)

100Base-T
1000Base-T
10GBase-T

DT-LAN-CAT.6+
2881007
Page 114

Protection of a DSL interface

ADSL
HDSL
VDSL

PT 2-TELE

MNT-TAE D/WH

2882828
Page 129

2882394
Page 130

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

23

Surge protection and interference filters
Selection guide and applications
Protection of video signals

IN

OUT

C-UFB 5DC

PT 3-HF-12DC-ST + PT 1X2-BE

2797858
Page 140

2858043 + 2856113
Page 116

Protection of the SAT antenna connection

C-SAT-BOX
2880561
Page 142

Protection of the cable TV connection

MNT-TV-SAT D
2882284
Page 143

24

PHOENIX CONTACT

Surge protection and interference filters
Selection guide and applications
Protection of antenna signals

GPS
GSM
UMTS

CN-UB-280DC-3-BB

Optional

2801050
Page 136

CN-LAMBDA/4-2.25-BB
2801057
Page 138

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

25

Surge protection and interference filters
Surge protection for the power supply unit

The complete system
The protective devices in the “compact”
range offer a consistent installation concept. Uniform and high-capacity modules
are available for virtually all power supply
systems. Be it lightning arrester, surge arrester or a combination of the two, the design will persuade you with its consistent
and universal application.
Worldwide use
The voltage fluctuations in power supplies
vary from country to country. The surge
protection also has to deal with these
short-term (temporary) voltage fluctuations. Due to the high rated voltage of
350 V AC, the arresters in the “compact”
range have no limitations and can be used in
systems up to 240/415 V.

26

PHOENIX CONTACT

FLASHTRAB compact PLUS
High-performance type 1 lightning arresters with low protection level based on spark
gap technology for power supply systems up
to 240/415 V.
FLASHTRAB compact
Combined lighting and surge arrester for
power supply systems up to 240/415 V.
VALVETRAB compact
Space-saving surge arrester for all common power supply systems up to 240/415 V.

Combined solutions
The VALVETRAB compact type 2 surge
arresters, which are available as CombiRCD surge protection with residual current
device and Combi-MCB surge protection
with coordinated backup fuse, are equipped
with further functions.
Device protection in multiple versions
Type 3 device protection is designed to
provide protection for highly sensitive devices. Depending on installation location,
the following protective devices are available, for example:
– For DIN rail mounting – PLUGTRAB PT
– For cable ducts – BLOCKTRAB
– Socket attachment plugs – MAINTRAB

Surge protection and interference filters
Surge protection for the power supply unit

Plug-in to perfection
Universal plug-in capability ensures a high
degree of comfort, e.g., for insulation measurements in the system. Instead of tampering with the installation, just pull out the
plug.
The symmetrical plug design facilitates
plugging in both directions within the base
element. These protective devices can be
installed in any control cabinet environment
thanks to this flexible installation direction.

Innovative technology
The high breaking capacity of the innovative spark gaps also enables their use in lowvoltage high-current installations with
short-circuit currents of up to 50 kA. The
encapsulated lightning arresters are also
able to limit line follow currents so that
even small backup fuses are not affected.

Remote signaling
A common floating remote indication
contact enables remote signaling without
taking up extra space.

Different designs
Arresters in different designs are available
for the various areas of application.

Status at a glance
The mechanical status indicator provides
information locally at a glance.

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

27

Surge protection and interference filters
Surge protection for the power supply unit
Type 1 lightning arresters
FLASHTRAB compact PLUS

H

H

– Seamless pluggability (even for N/PE
spark gap)
– Thermal disconnect device for each individual connector
– Optical, mechanical status indication for
the individual arresters
– With floating remote indication contact
– Connectors can be checked with
CHECKMASTER
– High continuous voltage of 350 V AC for
230/400 V AC networks with high voltage fluctuations

W

D

W

D

5-conductor system; L1, L2, L3, N, PE

4-conductor system; L1, L2, L3, PEN

Notes:
Total width 142.8 mm

For certifications, see page 154

Total width 106.9 mm
12

N

14

11

PE

L1

L2

11

L1

L3

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

12

PEN

FM

L3

L2

Technical data

I / T1
240 V AC (230/400 V AC ... 240/415 V AC)

I / T1
240 V AC (230/400 V AC ... 240/415 V AC)

350 V AC / 350 V AC / -

- / - / 350 V AC

100 kA
50 As
2.50 MJ/Ω

75 kA
37.5 As
1.40 MJ/Ω

L-N / N-PE / L-PEN

25 kA / 100 kA / -

- / - / 75 kA (3L-PEN)

L-N / N-PE / L-PEN

50 kA (264 V AC) / 100 A / -

- / - / 50 kA (264 V AC)

L-N / N-PE / L-PEN

≤ 1.5 kV / ≤ 1.5 kV / -

- / - / ≤ 1.5 kV

≤ 100 ns / ≤ 100 ns / 315 A (gL/gG)
50 kA

- / - / ≤ 100 ns
315 A (gL/gG)
50 kA

142.8 mm / 97 mm / 71.5 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11 /
UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

106.9 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11 /
UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

L-N / N-PE / L-PEN

14
FM

Lightning test curr. Iimp (10/350) µs
Peak value
Charge
Specific energy
Nominal discharge surge current In (8/20) µs
Follow current quenching capacity Ifi
Protection level UP
Response time tA
L-N / N-PE / L-PEN
Backup fuse max. in acc. with IEC
Immunity to short-circuiting (with max. backup fuse) IP
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

Ordering data
Description

Ordering data

Type

Order No.

FLT-CP-PLUS-3S-350

2882640

Pcs. /
Pkt.

Pcs. /
Pkt.

Type

Order No.

FLT-CP-PLUS-3C-350

2882653

1

2859913

10

FLASHTRAB compact PLUS
1

Accessories

Accessories

Replacement connector
L-N / L-PEN
N-PE
Labeling material

28

PHOENIX CONTACT

FLT-CP-PLUS-350-ST
FLT-CP-N/PE-350-ST
ZBN 18 ..., see page 63

2859913
2859686

10
10

FLT-CP-PLUS-350-ST
ZBN 18 ..., see page 63

Surge protection and interference filters
Surge protection for the power supply unit
H

H
W

D

H
W

D

4-conductor system; L1, L2, N, PE

D

3-conductor system; L1, L2, PEN

Total width 106.9 mm

3-conductor system; L, N, PE

Total width 71.6 mm
12

N

11

PE

Total width 71.6 mm

14

PEN

12

FM

14

11

L1

L2

L1

Technical data

W

N

12

FM

14

11

L2

PE

Technical data

FM

L1

Technical data

I / T1
240 V AC (230/400 V AC ... 240/415 V AC)

I / T1
240 V AC (230/400 V AC ... 240/415 V AC)

I / T1
240 V AC (230/400 V AC ... 240/415 V AC)

350 V AC / 350 V AC / -

- / - / 350 V AC

350 V AC / 350 V AC / -

75 kA
37.5 As
1.40 MJ/Ω

50 kA
25 As
625.00 kJ/Ω

50 kA
25 As
625.00 kJ/Ω

25 kA / 100 kA / -

- / - / 25 kA

25 kA / 100 kA / -

50 kA (264 V AC) / 100 A / -

- / - / 50 kA (264 V AC)

50 kA (264 V AC) / 100 A / -

≤ 1.5 kV / ≤ 1.5 kV / -

- / - / ≤ 1.5 kV

≤ 1.5 kV / ≤ 1.5 kV / -

≤ 100 ns / ≤ 100 ns / 315 A (gL/gG)
50 kA

- / - / ≤ 100 ns
315 A (gL/gG)
50 kA

≤ 100 ns / ≤ 100 ns / 315 A (gL/gG)
50 kA

106.9 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11 /
UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

71.6 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11 /
UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

71.6 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11 /
UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

Ordering data

Ordering data

Type

Order No.

FLT-CP-PLUS-2S-350

2882666

Pcs. /
Pkt.

1

Type

Order No.

FLT-CP-PLUS-2C-350

2882679

Accessories
FLT-CP-PLUS-350-ST
FLT-CP-N/PE-350-ST
ZBN 18 ..., see page 63

Ordering data
Pcs. /
Pkt.

1

Order No.

FLT-CP-PLUS-1S-350

2882682

1

2859913
2859686

10
10

Accessories
2859913
2859686

10
10

FLT-CP-PLUS-350-ST
ZBN 18 ..., see page 63

Pcs. /
Pkt.

Type

Accessories
2859913

10

FLT-CP-PLUS-350-ST
FLT-CP-N/PE-350-ST
ZBN 18 ..., see page 63

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

29

Surge protection and interference filters
Surge protection for the power supply unit
Type 1 lightning arresters
FLASHTRAB compact PLUS

H

H

– Seamless pluggability (even for N/PE
spark gap)
– Thermal disconnect device for each individual connector
– Optical, mechanical status indication for
the individual arresters
– With floating remote indication contact
– Connectors can be checked with
CHECKMASTER
– High continuous voltage of 350 V AC for
230/400 V AC networks with high voltage fluctuations

D

W

W

D

2-conductor system; L, PEN

N-PE spark gap,
for Lightning Protection Level 1

Notes:
Total width 35.8 mm

For certifications, see page 154

Total width 35.8 mm

PEN

12
11

14

N

14

11

L1

FM

PE

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

12

FM

Technical data

I / T1
240 V AC (230/400 V AC ... 240/415 V AC)

I / T1
240 V AC (N-PE)

350 V AC / - / 350 V AC

- / 350 V AC / -

25 kA
12.5 As
160.00 kJ/Ω

100 kA
50 As
2.50 MJ/Ω

L-N / N-PE / L-PEN

25 kA / - / 25 kA

- / 100 kA / -

L-N / N-PE / L-PEN

50 kA (264 V AC) / - / 50 kA (264 V AC)

- / 100 A / -

L-N / N-PE / L-PEN

≤ 1.5 kV / - / ≤ 1.5 kV

- / ≤ 1.5 kV / -

- / - / ≤ 100 ns
315 A (gL/gG)
50 kA

- / ≤ 100 ns / 25 kA

35.8 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11 /
UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

35.8 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11 /
UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

L-N / N-PE / L-PEN
Lightning test curr. Iimp (10/350) µs
Peak value
Charge
Specific energy
Nominal discharge surge current In (8/20) µs
Follow current quenching capacity Ifi
Protection level UP
Response time tA
L-N / N-PE / L-PEN
Backup fuse max. in acc. with IEC
Immunity to short-circuiting (with max. backup fuse) I P
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

Ordering data
Description

Ordering data

Type

Order No.

FLT-CP-PLUS-1C-350

2882695

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

FLASHTRAB compact PLUS
1

FLASHTRAB compact
FLT-CP-N/PE-350

Accessories

2859754

1

2859686

10

Accessories

Replacement connector
L-N / L-PEN
N-PE
Labeling material

30

PHOENIX CONTACT

FLT-CP-PLUS-350-ST

2859913

10
FLT-CP-N/PE-350-ST

ZBN 18 ..., see page 63

ZBN 18 ..., see page 63

Surge protection and interference filters
Surge protection for the power supply unit
Type 1 lightning arresters
FLASHTRAB

H

H

–
–
–
–

1-channel
Triggered
High discharge capacity
Good follow current quenching capacity
with higher rated voltage
– Direct parallel connection with type 2 arresters supported

W

D

W

D

Notes:
For certifications, see page 154

2.5 kV/3 kV protection level

N-PE spark gap, single-channel, plug-in

Total width 35.5 mm

Total width 35.8 mm

L/N ( )
L/N( )

L/N( )

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

Technical data

... 2.5
I / T1
230 V AC (400 V AC)

... 3.0
I / T1
230 V AC (400 V AC)

... 1.5
I / T1
230 V AC (N-PE)

440 V AC / - / 440 V AC

440 V AC / - / 440 V AC

- / 260 V AC / -

50 kA
25 As
625.00 kJ/Ω

50 kA
25 As
625.00 kJ/Ω

100 kA
50 As
2.50 MJ/Ω (N-PE)

L-N / N-PE / L-PEN

50 kA / - / 50 kA

50 kA / - / -

- / 100 kA / -

L-N / N-PE / L-PEN

≤ 2.5 kV / - / ≤ 2.5 kV

≤ 3 kV / - / ≤ 3 kV

- / ≤ 1.5 kV / -

L-N / N-PE / L-PEN

L/N ( )

Lightning test curr. Iimp (10/350) µs
Peak value
Charge
Specific energy
Nominal discharge surge current In (8/20) µs
Protection level UP
Response time tA
L-N / N-PE / L-PEN
Backup fuse max. in acc. with IEC
Immunity to short-circuiting (with max. backup fuse) IP
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards

≤ 100 ns / - / ≤ 100 ns

≤ 100 ns / - / ≤ 100 ns
500 A (NH-gL)
25 kA (440 V AC)

- / ≤ 100 ns / -

35.5 mm / 150 mm / 80.5 mm
10 ... 50 mm² / 16 ... 35 mm² / 6 - 1
-40 °C ... 85 °C
V0
IEC 61643-1 / DIN EN 61643-11 / DIN EN 61643-11/A11

35.8 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11

Ordering data
Description
FLASHTRAB PLUS CTRL
Without status indicator
FLASHTRAB PLUS CTRL
With status indicator

Type

Ordering data
Order No.

Pcs. /
Pkt.

FLT-PLUS CTRL-2.5
FLT-PLUS CTRL-3.0

2800121
2800168

1
1

FLT-PLUS CTRL-2.5/I
FLT-PLUS CTRL-3.0/I

2800122
2800170

1
1

Type

Order No.

Pcs. /
Pkt.

FLASHTRAB
FLT 100 N/PE-1.5

Accessories
Labeling material
Wiring bridge

ZBN 18 ..., see page 63
MPB ..., see page 61

2800303

1

Accessories
ZBN 18 ..., see page 63
MPB ..., see page 61

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

31

Surge protection and interference filters
Surge protection for the power supply unit
Type 1 lightning arresters
POWERTRAB

Notes:

H

For certifications, see page 154

D

– Type 1 arrester based on a varistor
– Meets Lightning Protection Level I
– Universal solution for various network
types:
500 ... 690 V AC IT systems
554/960 V AC TN-C systems
400/690 V AC TN-C systems
– Multi-stage status monitoring via remote
indication contact
– Local optical status indication
– Encapsulated, non-extinguishing
– Free of leakage current/no line follow current
– Very high TOV resistance
– Meets installation requirements according
to CLC/TS 50539-22
– Use in harsh industrial environments

W

Single-channel

Total width 56 mm
12 22
11 21 FM

PE / PEN /

Technical data
Electrical data
IEC category
Nominal voltage UN
Maximum continuous operating voltage UC
TOV behavior at UT
Nominal load current IL
Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax (8/20) µs
Lightning test current Iimp (10/350) µs

I, II / T1, T2
690 V AC
800 V AC
1500 V AC (5 sec.)
150 A (Serial through wiring with 50 mm2)
35 kA
100 kA
Peak value Iimp

Max. required backup fuse with V-type through wiring

35 kA
≤ 4.5 kV
400 A (gG; 2 x 50 mm2)
800 A (aR)
150 A (gG; ≥ 35 mm2)

Short-circuit resistance IP with max. backup fuse (effective)

50 kA

Protection level UP
Max. required backup fuse with branch wiring

General data
Dimensions W / H / D
Ambient temperature (operation)
Degree of protection in acc. with IEC 60529/ EN 60529
Housing material
Inflammability class in acc. with UL 94
Test standards
Conductor
Connection name
Connection method
Screw thread
Connection data solid / stranded / AWG
Protective conductor connection
Connection name
Connection method
Screw thread
Connection data solid / stranded / AWG
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

56 mm / - / 191 mm
-40 °C ... 80 °C
IP20
PA / PC
V-2
IEC 61643-11 / EN 61643-11/A11
Double terminal point
Screw connection
M6
16 ... 50 mm² / 16 ... 50 mm² / 6 - 1/0
PE conductor connection
Ring cable lug
M10
16 ... 95 mm² / 16 ... 95 mm² / 6 - 3/0
N/C contact 1-pos.
0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
30 V AC / 30 V DC
1.5 A AC / 1.5 A DC

Ordering data
Description

Type

Order No.

PWT 35-800AC-FM

2800419

Pcs. /
Pkt.

POWERTRAB
Mounting set, comprising: 1x PE aluminum rail (147.5 x 30 x 3 mm),
3x M10x20 hexagon-head screw, 3x M10 hexagonal nut,
3x M10 washer, 3x M10 spring washer, 1x installation instructions

32

PHOENIX CONTACT

1

Surge protection and interference filters
Surge protection for the power supply unit
H
W

D

4-conductor system; L1, L2, L3, PE/PEN

Mounting set

Total width 176 mm

L1

L2

L3

12 22
11 21 FM

PE / PEN /

Technical data
I, II / T1, T2
690 V AC
800 V AC
1500 V AC (5 sec.)
150 A (Serial through wiring with 50 mm2)
35 kA (per position)
100 kA (per position)
35 kA (per position)
≤ 4.5 kV
400 A (gG; 2 x 50 mm2)
800 A (aR)
150 A (gG; ≥ 35 mm2)
50 kA

176 mm / - / 191 mm
-40 °C ... 80 °C
IP20
PA / PC
V-2
IEC 61643-11 / EN 61643-11/A11
Double terminal point
Screw connection
M6
16 ... 50 mm² / 16 ... 50 mm² / 6 - 1/0
PE conductor connection
Ring cable lug
M10
16 ... 95 mm² / 16 ... 95 mm² / 6 - 3/0
N/C contact 1-pos.
0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
30 V AC / 30 V DC
1.5 A AC / 1.5 A DC

Ordering data

Ordering data

Type

Order No.

PWT 100-800AC-FM

2800531

Pcs. /
Pkt.

Type

Order No.

PWT CCT-SET

2800532

Pcs. /
Pkt.

1

1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

33

Surge protection and interference filters
Surge protection for the power supply unit
Type 1/2 lightning arrester/surge
arrester
VAL-MS-T1/T2
– Seamless pluggability (even for N/PE
spark gap)
– Secure hold of connectors in the event of
high lightning current loads and strong vibration thanks to new latching
– Thermal disconnect device for each individual connector
– Optical, mechanical status indication for
the individual arresters
– With or without floating remote indication contact
– Mechanical keying of all slots
– Connectors can be checked with
CHECKMASTER

H

H
D

W

D

W

5-conductor system;
L1, L2, L3, N, PE (3+1 circuit)

5-conductor system;
L1, L2, L3, N, PE (4+0 circuit)

Total width 71.2 mm
12

Notes:

11

For certifications, see page 154

Total width 71.2 mm
12

14
FM

L1

L2

L3

Maximum continuous operating voltage UC
L-N / L-PE / N-PE / L-PEN
Lightning test curr. Iimp (10/350) µs
Peak value
Charge
Specific energy
Follow current quenching capacity Ifi
L-N / L-PE / N-PE / L-PEN
Nominal discharge surge current In (8/20) µs
L-N / L-PE / N-PE / L-PEN
Max. discharge surge current Imax. (8/20) µs
L-N / L-PE / N-PE / L-PEN
Protection level UP
L-N / L-PE / N-PE / L-PEN
Backup fuse max. in acc. with IEC
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

UC

L2

L3

N

Technical data

...335
I, II / T1, T2
240 V AC (230/400 V AC ...
240/415 V AC)

...175
I, II / T1, T2
120 V AC

...335
I, II / T1, T2
240 V AC (230/400 V AC ... 240/415 V AC)

335 V AC / - / 264 V AC / -

175 V AC / - / 264 V AC / -

- / 335 V AC / 335 V AC / -

50 kA
25 As
625.00 kJ/Ω

50 kA
25 As
625.00 kJ/Ω

50 kA
25 As
625.00 kJ/Ω

- / - / 100 A (264 V AC) / -

- / - / 100 A (264 V AC) / -

-

12.5 kA / - / 50 kA / -

12.5 kA / - / 50 kA / -

- / 37.5 kA (3 x L) / 12.5 kA / -

50 kA / - / 50 kA / -

50 kA / - / 50 kA / -

- / 150 kA (3 x L) / 50 kA / -

≤ 1.2 kV / ≤ 2 kV / ≤ 1.7 kV / 160 A (gL/gG)

≤ 0.8 kV / ≤ 2 kV / ≤ 1.7 kV / 160 A (gL/gG)

- / ≤ 1.2 kV / ≤ 1.2 kV / 160 A (gL/gG)

71.2 mm / 99 mm / 77.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)

71.2 mm / 99 mm / 77.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)

Ordering data
Description

FM

L1

N

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN

14

11

Ordering data

Type

Order No.

VAL-MS-T1/T2 335/12.5/3+1-FM
VAL-MS-T1/T2 335/12.5/3+1
VAL-MS-T1/T2 175/12.5/3+1-FM
VAL-MS-T1/T2 175/12.5/3+1

2800183
2800184
2800670
2800671

Pcs. /
Pkt.

Pcs. /
Pkt.

Type

Order No.

VAL-MS-T1/T2 335/12.5/4+0-FM
VAL-MS-T1/T2 335/12.5/4+0

2800644
2800645

1
1

2800190

10

VALVETRAB-MS, varistor-based lightning arrester
with remote indication contact
without remote indication contact
with remote indication contact
without remote indication contact
with remote indication contact
without remote indication contact

335 V AC
335 V AC
175 V AC
175 V AC
75 V AC
75 V AC

1
1
1
1

Accessories

Accessories

Replacement connector
L-N / L-PEN
L-N / L-PEN
L-N / L-PEN
N-PE
Labeling material

34

PHOENIX CONTACT

VAL-MS-T1/T2 335/12.5 ST
VAL-MS-T1/T2 175/12.5 ST

2800190
2800676

10
10

F-MS-T1/T2 50 ST

2800191

10

ZBN 18 ..., see page 63

VAL-MS-T1/T2 335/12.5 ST

ZBN 18 ..., see page 63

Surge protection and interference filters
Surge protection for the power supply unit
H
D

H
W

D

4-conductor system; L1, L2, L3, PEN

H
W

D

3-conductor system; L, N, PE

Total width 53.4 mm

2-conductor system; L, N/PEN

Total width 35.6 mm

12

14

PEN

11

L1

Total width 17.5 mm

12

PEN

FM

L

14

14

11 FM

L

L3

Technical data

12

FM

11

L2

W

N

N / PEN

Technical data

Technical data

...335
I, II / T1, T2
240 V AC (230/400 V AC ...
240/415 V AC)

...175
I, II / T1, T2
120 V AC

...335
I, II / T1, T2
240 V AC
(230 V AC ... 240 V AC)

...175
I, II / T1, T2
120 V AC

...335
I, II / T1, T2
240 V AC

...175
I, II / T1, T2
120 V AC

... 48
I, II / T1, T2
60 V AC/DC

- / - / - / 335 V AC

- / - / - / 175 V AC

335 V AC / - / 264 V AC / -

175 V AC / - / 264 V AC / -

335 V AC / - / - / - 175 V AC / - / - / - 75 V AC / - / - / -

37.5 kA
18.75 As
352.00 kJ/Ω

37.5 kA
18.75 As
352.00 kJ/Ω

25 kA
12.5 As
160.00 kJ/Ω

25 kA
12.5 As
160.00 kJ/Ω

12.5 kA
6.25 As
39.00 kJ/Ω

12.5 kA
6.25 As
39.00 kJ/Ω

12.5 kA
6.25 As
39.00 kJ/Ω

-

-

- / - / 100 A (264 V AC) / -

- / - / 100 A (264 V AC) / -

-

-

-

- / - / - / 37.5 kA (3 x L)

- / - / - / 37.5 kA (3 x L)

12.5 kA / - / 50 kA / -

12.5 kA / - / 50 kA / -

/ - / - / 12.5 kA

/ - / - / 12.5 kA

- / - / - / 12.5 kA

- / - / - / 150 kA (3 x L)

- / - / - / 150 kA (3 x L)

50 kA / - / 50 kA / -

50 kA / - / 50 kA / -

/ - / - / 50 kA

/ - / - / 50 kA

- / - / - / 30 kA

- / - / - / ≤ 1.2 kV
160 A (gL/gG)

- / - / - / ≤ 0.7 kV
160 A (gL/gG)

≤ 1.2 kV / ≤ 2 kV / ≤ 1.7 kV / 160 A (gL/gG)

≤ 0.8 kV / ≤ 2 kV / ≤ 1.7 kV / 160 A (gL/gG)

≤ 1.2 kV / - / - / - ≤ 0.8 kV / - / - / - ≤ 0.4 kV / - / - / 160 A (gL/gG) 160 A (gL/gG) 160 A (gL/gG)

53.4 mm / 99 mm / 77.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)

35.6 mm / 99 mm / 77.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)

17.5 mm / 99 mm / 77.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC
1.5 A AC / 1.5 A DC (30 V DC)

Ordering data

Ordering data

Ordering data

Type

Order No.

VAL-MS-T1/T2 335/12.5/3+0-FM
VAL-MS-T1/T2 335/12.5/3+0
VAL-MS-T1/T2 175/12.5/3+0-FM
VAL-MS-T1/T2 175/12.5/3+0

2800188
2800189
2800672
2800673

Pcs. /
Pkt.

1
1
1
1

Type

Order No.

VAL-MS-T1/T2 335/12.5/1+1-FM
VAL-MS-T1/T2 335/12.5/1+1
VAL-MS-T1/T2 175/12.5/1+1-FM
VAL-MS-T1/T2 175/12.5/1+1

2800186
2800187
2800674
2800675

Accessories
VAL-MS-T1/T2 335/12.5 ST
VAL-MS-T1/T2 175/12.5 ST

ZBN 18 ..., see page 63

Pcs. /
Pkt.

1
1
1
1

Order No.

VAL-MS-T1/T2 335/12.5/1+0-FM
VAL-MS-T1/T2 335/12.5/1+0
VAL-MS-T1/T2 175/12.5/1+0-FM
VAL-MS-T1/T2 175/12.5/1+0
VAL-MS-T1/T2 48/12.5/1+0-FM
VAL-MS-T1/T2 48/12.5/1+0

2801042
2801041
2801044
2801043
2801240
2801241

1
1
1
1
1
1

2800190
2800676
2801242

10
10
10

Accessories
2800190
2800676

10
10

Accessories

VAL-MS-T1/T2 335/12.5 ST
VAL-MS-T1/T2 175/12.5 ST

2800190
2800676

10
10

F-MS-T1/T2 50 ST

2800191

10

ZBN 18 ..., see page 63

Pcs. /
Pkt.

Type

VAL-MS-T1/T2 335/12.5 ST
VAL-MS-T1/T2 175/12.5 ST
VAL-MS-T1/T2 48/12.5 ST
ZBN 18 ..., see page 63

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

35

Surge protection and interference filters
Surge protection for the power supply unit
Type 1+2 lightning/surge arrester
combination
FLASHTRAB compact
– Seamless pluggability (even for N/PE
spark gap)
– Thermal disconnect device for each individual connector
– Optical, mechanical status indication for
the individual arresters
– With floating remote indication contact
– Connectors can be checked with
CHECKMASTER
– High continuous voltage of 350 V AC for
230/400 V AC networks with high voltage fluctuations

H

H
W

D

D

5-conductor system; L1, L2, L3, N, PE

W

4-conductor system; L1, L2, L3, PEN

Notes:
Total width 142.8 mm

For certifications, see page 154

Total width 106.9 mm
12

N

14

11

PE

L1

L2

11

L1

L3

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

12

PEN

FM

L2

L3

Technical data

I + II / T1 + T2
240 V AC (230/400 V AC ... 240/415 V AC)

I + II / T1 + T2
240 V AC (230/400 V AC ... 240/415 V AC)

350 V AC / 350 V AC / -

- / - / 350 V AC

100 kA
50 As
2.50 MJ/Ω

75 kA (3-pos.)
37.5 As
1.40 MJ/Ω

L-N / N-PE / L-PEN

25 kA / 100 kA / -

- / - / 75 kA (all channels)

L-N / N-PE / L-PEN

25 kA (264 V AC) / 100 A / -

- / - / 25 kA (264 V AC)

L-N / N-PE / L-PEN

≤ 1.5 kV / ≤ 1.5 kV / -

- / - / ≤ 1.5 kV

L-N / N-PE / L-PEN
Backup fuse max. in acc. with IEC
Immunity to short-circuiting (with max. backup fuse) IP

≤ 25 ns / ≤ 100 ns / 315 A (gL/gG)
25 kA

- / - / ≤ 25 ns
315 A (gL / gG)
25 kA

General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

142.8 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

106.9 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

L-N / N-PE / L-PEN

14
FM

Lightning test curr. Iimp (10/350) µs
Peak value
Charge
Specific energy
Nominal discharge surge current In (8/20) µs
Follow current quenching capacity Ifi
Protection level UP
Response time tA

Ordering data
Description

Type

Ordering data
Order No.

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

FLASHTRAB compact
FLT-CP-3S-350

2859712

1

FLT-CP-3C-350

2859725

1

FLT-CP-350-ST

2881887

10

VAL-CP-350-ST

2859602

10

Accessories

Accessories

Replacement connector
L-N / L-PEN
N-PE
L-N / L-PEN
Labeling material

36

PHOENIX CONTACT

FLT-CP-350-ST
FLT-CP-N/PE-350-ST
VAL-CP-350-ST
ZBN 18 ..., see page 63

2881887
2859686
2859602

10
10
10

ZBN 18 ..., see page 63

Surge protection and interference filters
Surge protection for the power supply unit
H

H
W

D

D

4-conductor system; L1, L2, N, PE

H
W

D

3-conductor system; L1, L2, PEN

Total width 106.9 mm

3-conductor system; L, N, PE

Total width 71.6 mm
12

N

11

PE

L1

14

Total width 71.6 mm
12

PEN

FM

11

L1

L2

Technical data

W

14

12

N

FM

11

L2

PE

Technical data

L1

Technical data

I + II / T1 + T2
240 V AC (230/400 V AC ... 240/415 V AC)

I + II / T1 + T2
240 V AC (230/400 V AC ... 240/415 V AC)

I + II / T1 + T2
240 V AC (230 V AC ... 240 V AC)

350 V AC / 350 V AC / -

- / - / 350 V AC

350 V AC / 350 V AC / -

75 kA
37.5 As
1.40 MJ/Ω

50 kA (2-pos.)
25 As
625.00 kJ/Ω

50 kA
25 As
625.00 kJ/Ω

25 kA / 100 kA / -

- / - / 50 kA (all channels)

25 kA / 100 kA / -

25 kA (264 V AC) / 100 A / -

- / - / 25 kA (264 V AC)

25 kA (264 V AC) / 100 A / -

≤ 1.5 kV / ≤ 1.5 kV / -

- / - / ≤ 1.5 kV

≤ 1.5 kV / ≤ 1.5 kV / -

≤ 25 ns / ≤ 100 ns / 315 A (gL/gG)
25 kA

- / - / ≤ 25 ns
315 A (gL / gG)
25 kA

≤ 25 ns / ≤ 100 ns / 315 A (gL/gG)
25 kA

106.9 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

71.6 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

71.6 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

Ordering data
Type

Ordering data
Order No.

FLT-CP-2S-350

2859767

Pcs. /
Pkt.

1

Type

FLT-CP-350-ST
FLT-CP-N/PE-350-ST
VAL-CP-350-ST
ZBN 18 ..., see page 63

Ordering data
Order No.

FLT-CP-2C-350

Accessories

2859770

Pcs. /
Pkt.

1

Type

10
10
10

Pcs. /
Pkt.

2859738

1

2881887
2859686
2859602

10
10
10

Accessories

FLT-CP-350-ST

2881887

10

VAL-CP-350-ST

2859602

10

ZBN 18 ..., see page 63

Order No.

FLT-CP-1S-350

Accessories
2881887
2859686
2859602

14
FM

FLT-CP-350-ST
FLT-CP-N/PE-350-ST
VAL-CP-350-ST
ZBN 18 ..., see page 63

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

37

Surge protection and interference filters
Surge protection for the power supply unit
Type 1+2 lightning/surge arrester
combination
FLASHTRAB compact
– Seamless pluggability (even for N/PE
spark gap)
– Thermal disconnect device for each individual connector
– Optical, mechanical status indication for
the individual arresters
– With floating remote indication contact
– Connectors can be checked with
CHECKMASTER
– High continuous voltage of 350 V AC for
230/400 V AC networks with high voltage fluctuations

Notes:

H

For certifications, see page 154

D

W

2-conductor system; L, PEN

Total width 35.8 mm

PEN

12

14

11

FM

L1

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

I + II / T1 + T2
240 V AC (230 V AC ... 240 V AC)
L-N / N-PE / L-PEN

350 V AC / - / 350 V AC

Lightning test curr. Iimp (10/350) µs
Peak value
Charge
Specific energy

25 kA
12.5 As
160.00 kJ/Ω

Nominal discharge surge current In (8/20) µs
L-N / N-PE / L-PEN

25 kA / - / 25 kA

L-N / N-PE / L-PEN

25 kA (264 V AC) / - / 25 kA (264 V AC)

L-N / N-PE / L-PEN

≤ 1.5 kV / - / ≤ 1.5 kV

Follow current quenching capacity Ifi
Protection level UP
Response time tA
L-N / N-PE / L-PEN
Backup fuse max. in acc. with IEC
Immunity to short-circuiting (with max. backup fuse) IP

≤ 25 ns / - / ≤ 25 ns
315 A (gL / gG)
25 kA

General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards

35.8 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / UL 1449

Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

Ordering data
Pcs. /
Pkt.

Description

Type

Order No.

FLASHTRAB compact
1-pos.

FLT-CP-1C-350

2859741

1

FLT-CP-350-ST

2881887

10

VAL-CP-350-ST

2859602

10

Accessories
Replacement connector
L-N / L-PEN
N-PE
L-N / L-PEN
Labeling material

38

PHOENIX CONTACT

ZBN 18 ..., see page 63

Surge protection and interference filters
Surge protection for the power supply unit
H
W

D

N-PE spark gap,
for Lightning Protection Level 1

Total width 35.8 mm

N

12

14

11

FM

PE

Technical data
I / T1
240 V AC (N-PE)
- / 350 V AC / 100 kA
50 As
2.50 MJ/Ω
- / 100 kA / - / 100 A / - / ≤ 1.5 kV / - / ≤ 100 ns / 25 kA

35.8 mm / 95.8 mm / 70 mm
2.5 ... 35 mm² / 2.5 ... 25 mm² / 13 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11 /
UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC / 200 mA DC

Ordering data
Pcs. /
Pkt.

Type

Order No.

FLT-CP-N/PE-350

2859754

1

2859686

10

Accessories

FLT-CP-N/PE-350-ST
ZBN 18 ..., see page 63

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

39

Surge protection and interference filters
Surge protection for the power supply unit
Type 2 surge arresters
VALVETRAB compact

H

H

– Type 2 seamless plug-in surge arrester
– Disconnect device on each individual connector
– Optical, mechanical status indication for
the individual arresters
– With or without floating remote indication contact
– Mechanical keying of all slots
– Modular arrester blocks with ultra-slim
design
– Use of varistors that are free of leakage
current
– Connectors can be checked with
CHECKMASTER
– High continuous voltage of 350 V AC for
230/400 V AC networks with high voltage fluctuations

W

D

D

5-conductor system; L1, L2, L3, N, PE

W

4-conductor system; L1, L2, L3, PEN

Total width 49.2 mm

Total width 37.25 mm

N

12
11

PEN

14

12

FM

11

14
FM

Notes:
For certifications, see page 154

PE

L1

L2

L3

L1

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN

L2

L3

Technical data

... 350
II / T2
240 V AC (230/400 V AC ...
240/415 V AC)

... 175
II / T2
120 V AC

... 350
II / T2
240 V AC (230/400 V AC ...
240/415 V AC)

... 175
II / T2
120 V AC (3P/PEN)

L-N / N-PE / L-PEN

350 V AC / 264 V AC / -

175 V AC / 150 V AC / -

- / - / 350 V AC

- / - / 175 V AC

L-N / N-PE / L-PEN

20 kA / 20 kA / -

60 kA (all channels) / 20 kA / -

- / - / 60 kA (all channels)

- / - / 60 kA (all channels)

L-N / N-PE / L-PEN
L-N / N-PE / L-PEN

120 kA (all channels) / 40 kA / ≤ 1.1 kV / ≤ 0.25 kV / -

120 kA (all channels) / 40 kA / ≤ 600 V / ≤ 200 V / -

- / - / 120 kA (all channels)
- / - / ≤ 1.1 kV

- / - / 120 kA (all channels)
- / - / ≤ 600 V

L-N / N-PE / L-PEN

≤ 1.4 kV / ≤ 1.5 kV / -

≤ 850 V / ≤ 950 V / -

- / - / ≤ 1.4 kV

- / - / ≤ 850 V (at In)

L-N / N-PE / L-PEN

≤ 25 ns / ≤ 100 ns / 125 A (gL/gG)

≤ 25 ns / ≤ 100 ns / 125 A (gL/gG)

- / - / ≤ 25 ns
125 A (gL/gG)

- / - / ≤ 25 ns
125 A (gL/gG)

Maximum continuous operating voltage UC
Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Residual voltage at 5 kA
Protection level UP
Response time tA
Backup fuse max. in acc. with IEC
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

49.2 mm / 98.5 mm / 70 mm
2.5 ... 25 mm² / 2.5 ... 16 mm² / 12 - 4
-40 °C ... 80 °C
V0
IEC 61643-1 / DIN EN 61643-11 / DIN EN 61643-11/A11 /
IEEE C62.1 / C62.34 / C62.45 / UL 1449
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC (ohmic) / 200 mA DC (ohmic)

37.25 mm / 98.5 mm / 70 mm
2.5 ... 25 mm² / 2.5 ... 16 mm² / 12 - 4
-40 °C ... 80 °C
V0
IEC 61643-1 / DIN EN 61643-11 / UL 1449 /
IEEE C62.1 / C62.34 / C62.45
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC (ohmic) / 200 mA DC (ohmic)

Ordering data

Ordering data
Pcs. /
Pkt.

Description

Type

Order No.

VALVETRAB compact
with remote indication contact
without remote indication contact
with remote indication contact
Bridge set, for bridging VALVETRAB compact to the r.c.c.b.

VAL-CP-3S-350
VAL-CP-3S-350/O
VAL-CP-3S-175

2859521
2881010
2859453

1
1
1

MPB SET VAL-CP-3S

2880684

1

Pcs. /
Pkt.

Type

Order No.

VAL-CP-3C-350
VAL-CP-3C-350/O
VAL-CP-3C-175

2859547
2881023
2859466

1
1
1

VAL-CP-350-ST

2859602

10

VAL-CP-175-ST

2859628

10

Accessories

Accessories

Replacement connector
L-N / L-PEN
N-PE
L-N / L-PEN
Labeling material

40

PHOENIX CONTACT

VAL-CP-350-ST
VAL-CP-N/PE-350-ST
VAL-CP-175-ST
ZBFM 5 ..., see page 63

2859602
2859699
2859628

10
10
10

ZBFM 5 ..., see page 63

Surge protection and interference filters
Surge protection for the power supply unit
H

H
W

D

D

4-conductor system; L1, L2, N, PE

H
W

3-conductor system; L1, L2, PEN

Total width 37.25 mm

3-conductor system; L, N, PE

Total width 25.3 mm

N

12
11

PE

L1

W

D

Total width 25.3 mm

PEN

14

12

FM

11

L2

L1

Technical data

N

14

12

FM

11

L2

PE

Technical data

14
FM

L1

Technical data

... 350
II / T2
240 V AC (230/400 V AC ...
240/415 V AC)

... 175
II / T2
120 V AC

... 350
II / T2
240 V AC (230/400 V AC ...
240/415 V AC)

... 175
II / T2
120 V AC (2P/PEN)

... 350
II / T2
240 V AC (230/400 V AC ...
240/415 V AC)

... 175
II / T2
120 V AC

350 V AC / 264 V AC / -

175 V AC / 150 V AC / -

- / - / 350 V AC

- / - / 175 V AC

350 V AC / 264 V AC / -

175 V AC / 150 V AC / -

40 kA (all channels) / 20 kA / -

40 kA (all channels) / 20 kA / -

- / - / 40 kA (all channels)

- / - / 40 kA (all channels)

20 kA / 20 kA / -

20 kA / 20 kA / -

80 kA (all channels) / 40 kA / ≤ 1.1 kV / ≤ 0.25 kV / -

80 kA (all channels) / 40 kA / ≤ 600 V / ≤ 200 V / -

- / - / 80 kA (all channels)
- / - / ≤ 1.1 kV

- / - / 80 kA (all channels)
- / - / ≤ 600 V

40 kA / 40 kA / ≤ 1.1 kV / ≤ 0.25 kV / -

40 kA / 40 kA / ≤ 600 V / ≤ 200 V / -

≤ 1.4 kV / ≤ 1.5 kV / -

≤ 850 V / ≤ 950 V / -

- / - / ≤ 1.4 kV

- / - / ≤ 850 V (at In)

≤ 1.4 kV / ≤ 1.5 kV / -

≤ 850 V / ≤ 950 V / -

≤ 25 ns / ≤ 100 ns / 125 A (gL/gG)

≤ 25 ns / ≤ 100 ns / 125 A (gL/gG)

- / - / ≤ 25 ns
125 A (gL/gG)

- / - / ≤ 25 ns
125 A (gL/gG)

≤ 25 ns / ≤ 100 ns / 125 A (gL/gG)

≤ 25 ns / ≤ 100 ns / 125 A (gL/gG)

37.25 mm / 98.5 mm / 70 mm
2.5 ... 25 mm² / 2.5 ... 16 mm² / 12 - 4
-40 °C ... 80 °C
V0
IEC 61643-1 / DIN EN 61643-11 / DIN EN 61643-11/A11 /
IEEE C62.1 / C62.34 / C62.45 / UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC (ohmic) / 200 mA DC (ohmic)

25.3 mm / 98.5 mm / 70 mm
2.5 ... 25 mm² / 2.5 ... 16 mm² / 12 - 4
-40 °C ... 80 °C
V0
IEC 61643-1 / DIN EN 61643-11 / UL 1449 /
IEEE C62.1 / C62.34 / C62.45
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC (ohmic) / 200 mA DC (ohmic)

25.3 mm / 98.5 mm / 70 mm
2.5 ... 25 mm² / 2.5 ... 16 mm² / 12 - 4
-40 °C ... 80 °C
V0
IEC 61643-1 / DIN EN 61643-11 / DIN EN 61643-11/A11 /
IEEE C62.1 / C62.34 / C62.45 / UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC (ohmic) / 200 mA DC (ohmic)

Ordering data

Ordering data

Ordering data

Type

Order No.

VAL-CP-2S-350
VAL-CP-2S-350/O
VAL-CP-2S-175

2859505
2881049
2859495

Pcs. /
Pkt.

1
1
1

Type

Order No.

VAL-CP-2C-350
VAL-CP-2C-350/O
VAL-CP-2C-175

2859589
2881052
2859482

Accessories
VAL-CP-350-ST
VAL-CP-N/PE-350-ST
VAL-CP-175-ST
ZBFM 5 ..., see page 63

Pcs. /
Pkt.

1
1
1

Order No.

VAL-CP-1S-350
VAL-CP-1S-350/O
VAL-CP-1S-175

2859563
2881036
2859479

1
1
1

2859602
2859699
2859628

10
10
10

Accessories
2859602
2859699
2859628

10
10
10

Accessories

VAL-CP-350-ST

2859602

10

VAL-CP-175-ST

2859628

10

ZBFM 5 ..., see page 63

Pcs. /
Pkt.

Type

VAL-CP-350-ST
VAL-CP-N/PE-350-ST
VAL-CP-175-ST
ZBFM 5 ..., see page 63

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

41

Surge protection and interference filters
Surge protection for the power supply unit
Type 2 surge arresters
VALVETRAB MS
30/40 kA performance class
– Multi-channel type 2 arrester
– Type 2 seamless plug-in surge arrester
– Disconnect device on each individual connector
– Optical, mechanical status indication for
the individual arresters
– With or without floating remote indication contact
– Mechanical keying of all slots

H

H
D

W

D

5-conductor system; L1, L2, L3, N, PE,
supply line supply from below

Notes:

W

5-conductor system; L1, L2, L3, N, PE,
supply line supply from above

For certifications, see page 154

Total width 70.8 mm
12

Total width 70.8 mm

N

14

11

L1

L2

L3

FM

FM

L1

L2

L3

N

14

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

11
12

Technical data

VAL-MS 230
II / T2
230 V AC (400 V AC)

VAL-MS 320
II / T2
230 V AC (400 V AC)

VAL-MS 320
II / T2
230 V AC (400 V AC)

L-N / N-PE / L-PEN

275 V AC / 260 V AC / -

335 V AC / 260 V AC / -

335 V AC / 260 V AC / -

L-N / N-PE / L-PEN

20 kA / 20 kA / -

20 kA / 20 kA / -

20 kA / 20 kA / -

L-N / N-PE / L-PEN
L-N / N-PE / L-PEN

40 kA / 40 kA / ≤ 1.1 kV / ≤ 0.15 kV / -

40 kA / 40 kA / ≤ 1.25 kV / ≤ 0.15 kV / -

40 kA / 40 kA / ≤ 1.25 kV / ≤ 0.15 kV / -

L-N / N-PE / L-PEN

≤ 1.35 kV / ≤ 1.5 kV / -

≤ 1.6 kV / ≤ 1.5 kV / -

≤ 1.6 kV / ≤ 1.5 kV / -

≤ 25 ns / ≤ 100 ns / 125 A (gL)
25 kA

≤ 25 ns / ≤ 100 ns / 125 A (gL)
25 kA

Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Residual voltage at 5 kA
Protection level UP
Response time tA
L-N / N-PE / L-PEN
Backup fuse max. in acc. with IEC
Immunity to short-circuiting (with max. backup fuse) IP

≤ 25 ns / ≤ 100 ns / -

General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

70.8 mm / 96.8 mm / 65.5 mm
0.5 ... 35 mm² / 0.5 ... 25 mm² / 20 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
0.75 A AC (250 V AC) / 1 A DC (30 V DC)

70.8 mm / 96.8 mm / 65.5 mm
0.5 ... 35 mm² / 0.5 ... 25 mm² / 20 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
0.75 A AC (250 V AC) / 1 A DC (30 V DC)

Ordering data
Description

Imax

UC

Ordering data

Type

Order No.

VAL-MS 230/3+1
VAL-MS 230/3+1 FM
VAL-MS 320/3+1
VAL-MS 320/3+1/FM

2838209
2838199
2859178
2859181

Pcs. /
Pkt.

Pcs. /
Pkt.

Type

Order No.

VAL-MS 320/3+1/FM-UD

2856689

1

VALVETRAB, multi-position surge arrester combination
without remote indication contact
with remote indication contact
without remote indication contact
with remote indication contact
VALVETRAB MS
without remote indication contact
with remote indication contact

40 kA
40 kA
40 kA
40 kA

275 V AC
275 V AC
335 V AC
335 V AC

30 kA
30 kA

580 V AC
580 V AC

1
1
1
1

Accessories

Accessories

Replacement connector
1L-N/PE
1L-N/PE
1L-N/PE
N-PE
Marking material

42

PHOENIX CONTACT

VAL-MS 230 ST
VAL-MS 320 ST

2798844
2838843

10
10

VAL-MS 320-UD ST

2858315

10

F-MS 12 ST

2817990

10

F-MS 12 ST

2817990

10

ZBN 18 ..., see page 63

ZBN 18 ..., see page 63

Surge protection and interference filters
Surge protection for the power supply unit
H
D

H
W

D

4-conductor system; L1, L2, L3, PEN

H
W

D

3-conductor system; L, N, PE

Total width 53.4 mm

3-conductor system; L1, L2, PEN

Total width 35.6 mm

12

14

PEN

Total width 35.6 mm
12

PEN

12

14

PEN

11 FM

FM

11

W

L1

L2

L1

L3

Technical data

N

L1

Technical data

L2

Technical data

VAL-MS 320
II / T2
230 V AC (Max. 240/415 V AC)

VAL-MS 580
II / T2
400 V AC (400/690 V AC TN-C)

VAL-MS 230
II / T2
230 V AC

VAL-MS 320
II / T2
230 V AC

VAL-MS 230
II / T2
230 V AC (400 V AC)

- / - / 335 V AC

- / - / 580 V AC

275 V AC / 260 V AC / -

335 V AC / 260 V AC / -

- / - / 275 V AC

- / - / 60 kA (all channels)

- / - / 45 kA (all channels)

20 kA / 20 kA / -

20 kA / 20 kA / -

- / - / 40 kA (all channels)

- / - / 120 kA (all channels)
- / - / ≤ 1.2 kV

- / - / 90 kA (all channels)
- / - / ≤ 2.1 kV

40 kA / 40 kA / ≤ 1.1 kV / ≤ 150 V / -

40 kA / 40 kA / - 1.2 kV / ≤ 150 V / -

- / - / 80 kA (all channels)
- / - / ≤ 1.1 kV

- / - / ≤ 1.5 kV

- / - / ≤ 2.5 kV

≤ 1.35 kV / ≤ 1.5 kV / -

≤ 1.5 kV / ≤ 1.5 kV / -

- / - / ≤ 1.35 kV

≤ 25 ns / ≤ 100 ns / 125 A (gL/gG)
25 kA

- / - / ≤ 25 ns
125 A (gL/gG)
25 kA

- / - / ≤ 25 ns

- / - / ≤ 25 ns
125 A (gL / gG)
25 kA

≤ 25 ns / ≤ 100 ns / -

53.4 mm / 99 mm / 65.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1 A DC (30 V DC)

35.6 mm / 97 mm / 65.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1 A DC (30 V DC)

Ordering data

Ordering data

Type

Order No.

Pcs. /
Pkt.

VAL-MS 320/3+0
VAL-MS 320/3+0-FM

2920230
2920243

1
1

VAL-MS 580/3+0
VAL-MS 580/3+0-FM

2920450
2920447

1
1

VAL-MS 320 ST
VAL-MS 580-ST
ZBN 18 ..., see page 63

35.6 mm / 97 mm / 65.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1 A DC (30 V DC)

Ordering data

Type

Order No.

VAL-MS 230/1+1
VAL-MS 230/1+1-FM
VAL-MS 320/1+1
VAL-MS 320/1+1-FM

2804429
2804432
2804380
2804393

Accessories

Pcs. /
Pkt.

1
1
1
1

10
10

Order No.

VAL-MS 230/2+0
VAL-MS 230/2+0-FM

2800103
2800102

1
1

2798844

10

Accessories

VAL-MS 230 ST
VAL-MS 320 ST

2798844
2838843

10
10

F-MS 12 ST

2817990

10

ZBN 18 ..., see page 63

Pcs. /
Pkt.

Type

Accessories

2838843
2920434

14

11 FM

VAL-MS 230 ST

ZBN 18 ..., see page 63

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

43

Surge protection and interference filters
Surge protection for the power supply unit
Type 2 surge arresters
VALVETRAB MS

Notes:

H

For certifications, see page 154

D

– Single-channel, DIN-rail mountable protective devices
– Comprising base element and connector
– Base element with/without floating remote indication contact
– Disconnect device on each individual connector
– Optical, mechanical status indication for
the individual arresters
– Mechanical keying of all slots

W

2-conductor system; L, N/PEN

Total width 17.7 mm

L

12

14

11 FM

N / PEN

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

... 60AC
II / T2
60 V AC/DC

... 230AC
II / T2
230 V AC

L-N / N-PE / L-PEN

75 V AC / - / 75 V AC

275 V AC / - / 275 V AC

L-N / N-PE / L-PEN

15 kA / - / -

20 kA / - / 20 kA

L-N / N-PE / L-PEN
L-N / N-PE / L-PEN

40 kA / - / 40 kA
≤ 325 V / - / ≤ 325 V

40 kA / - / 40 kA
≤ 1 kV / - / ≤ 1 kV

L-N / N-PE / L-PEN

≤ 500 V / - / ≤ 500 V

≤ 1.35 kV / - / ≤ 1.35 kV

L-N / N-PE / L-PEN

≤ 25 ns / - / ≤ 25 ns

Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Residual voltage at 5 kA
Protection level UP
Response time tA
≤ 25 ns / - / ≤ 25 ns
125 A (gL/gG)

Backup fuse max. in acc. with IEC
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards

17.7 mm / - / 96.8 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11

Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1 A AC / 1 A DC

Ordering data
Pcs. /
Pkt.

Description

Type

Order No.

VALVETRAB MS
with remote indication contact
without remote indication contact
with remote indication contact
without remote indication contact

VAL-MS 60/FM
VAL-MS 60
VAL-MS 230/FM
VAL-MS 230

2868033
2868020
2839130
2839127

1
1
1
1

VAL-MS 60 ST
VAL-MS 230 ST

2807573
2798844

10
10

VALVETRAB, single-position base element
with remote indication contact
without remote indication contact

VAL-MS BE/FM
VAL-MS BE

2817738
2817741

10
10

Labeling material

ZBN 18 ..., see page 63

Accessories
Replacement connector
1L-N/PE
1L-N/PE

44

PHOENIX CONTACT

Surge protection and interference filters
Surge protection for the power supply unit
H
D

H
W

D

Spark gap, N-PE

W

2-conductor system; L, N/PEN

Total width 17.7 mm

Total width 17.7 mm

N

12

L

14

12

11 FM

14

11 FM

N / PEN

Technical data

Technical data

F-MS 12
II / T2
230 V AC

VAL-MS 350 VF
II / T2
230 V AC

- / 260 V AC / -

350 V AC / - / 350 V AC

- / 20 kA / -

10 kA / - / 10 kA

- / 40 kA / - / ≤ 150 V / -

20 kA / - / 20 kA
≤ 1 kV / - / ≤ 1 kV

- / ≤ 1.5 kV / -

≤ 1.5 kV / - / ≤ 1.5 kV

- / ≤ 100 ns / -

≤ 100 ns / - / ≤ 100 ns
125 A (gL)

17.7 mm / - / 96.8 mm
0.5 ... 35 mm² / 0.5 ... 25 mm² / 20 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11

17.7 mm / - / 96.8 mm
0.5 ... 35 mm² / 0.5 ... 25 mm² / 20 - 2
-40 °C ... 80 °C
IEC 61643-1 / EN 61643-11/A11 / NF C61-740 /
UL 1449
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1 A AC / 1 A DC

PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1 A AC / 1 A DC

Ordering data

Ordering data

Type

Order No.

F-MS 12/FM
F-MS 12

2817974
2817987

Pcs. /
Pkt.

1
1

Pcs. /
Pkt.

Type

Order No.

VAL-MS 350 VF/FM
VAL-MS 350VF

2856579
2856582

1
1

Accessories

Accessories

F-MS 12 ST

2817990

10

VAL-MS 350 VF ST

2856595

10

VAL-MS BE/FM
VAL-MS BE

2817738
2817741

10
10

VAL-MS BE/FM
VAL-MS BE

2817738
2817741

10
10

ZBN 18 ..., see page 63

ZBN 18 ..., see page 63

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

45

Surge protection and interference filters
Surge protection for the power supply unit
Type 2 surge protection plug for
VAL-MS base elements

Notes:
For certifications, see page 154
Please follow the installation instructions. These are provided with
the packaging documentation or can be downloaded from the corresponding product page online at www.phoenixcontact.net/products.
You can find a list of all possible combination options and safety
notes in the download area for the corresponding replacement
plug at www.phoenixcontact.net/products.

Plug, 1-pos., L-N/L-PEN

Total width 17.7 mm

– Thermal disconnect device for each individual connector
– Optical, mechanical status indication for
all protective connectors
– Connectors can be checked with
CHECKMASTER
Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC
Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax (8/20) µs
Residual voltage at 5 kA
Protection level UP
Response time tA:
Backup fuse max. in acc. with IEC
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Housing material
Inflammability class in acc. with UL 94
Test standards

... 120 ST
II / T2
120 V AC
150 V AC
20 kA
40 kA
≤ 550 V
≤ 800 V
≤ 25 ns

... 230 IT ST
... 400 ST
II / T2
II / T2
230 V AC
400 V AC
385 V AC
440 V AC
20 kA
20 kA
40 kA
40 kA
≤ 1.35 kV
≤ 1.5 kV
≤ 1.8 kV
≤ 2.2 kV
≤ 25 ns
≤ 25 ns
125 A (gL)

... 500 ST
II / T2
500 V AC
600 V AC
20 kA
30 kA
≤ 2.3 kV
≤ 2.7 kV
≤ 25 ns

17.7 mm / 52.4 mm / 54.5 mm
-40 °C ... 80 °C
IP20
PA
V0
IEC 61643-1 / EN 61643-11/A11 / UL 1449 /
IEEE C62.1 / C62.34 / C62.45

Ordering data
Description

Nominal voltage UN

Type

Order No.

Pcs. /
Pkt.

VAL-MS 120 ST
VAL-MS 230 IT ST
VAL-MS 400 ST
VAL-MS 500 ST

2807586
2807599
2816399
2807609

10
10
10
10

VALVETRAB surge protection plug
120 V AC
230 V AC
400 V AC
500 V AC

Accessories
VALVETRAB, base element for 4-wire systems, L1, L2, L3, PEN,
for individual assembly with VAL-MS...ST

46

PHOENIX CONTACT

with remote indication contact
3L-PEN
without remote indication contact
3L-PEN
VALVETRAB, base element for 3-wire systems, L1, L2, PEN, for
individual assembly with VAL-MS...ST

VAL-MS/3+0-BE/FM
VAL-MS/3+0-BE

2881803
2881816

1
1

with remote indication contact
without remote indication contact
VALVETRAB, single-position base element
with remote indication contact
without remote indication contact

VAL-MS/2+0-BE/FM
VAL-MS/2+0-BE

2805321
2804584

1
1

VAL-MS BE/FM
VAL-MS BE

2817738
2817741

10
10

2L-GND
2L - PEN

Surge protection and interference filters
Surge protection for the power supply unit
Type 2 surge protection plug for
VAL-MS base elements
– Specifically for use in American applications
– 1-pos.
– Thermal disconnect device for each individual connector
– Optical, mechanical status indication for
all protective connectors
– Connectors can be checked with
CHECKMASTER
Single-pos.

Single-pos.

Notes:
For certifications, see page 154
Please follow the installation instructions. These are provided with
the packaging documentation or can be downloaded from the corresponding product page online at www.phoenixcontact.net/products.
Total width 17.7 mm

Total width 17.7 mm

You can find a list of all possible combination options and safety
notes in the download area for the corresponding replacement
plug at www.phoenixcontact.net/products.

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC
Nominal discharge surge current In (8/20) µs
Residual voltage at 5 kA
Protection level UP
Backup fuse max. in acc. with IEC
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Housing material
Inflammability class in acc. with UL 94
Test standards

Description

... 60 ST
II / T2
60 V AC
75 V AC
10 kA
≤ 325 V
≤ 500 V

Nominal voltage UN

Technical data

... 120 ST
... 240 ST
II / T2
II / T2
120 V AC
240 V AC
150 V AC
275 V AC
20 kA
20 kA
≤ 550 V
≤ 1 kV
≤ 800 V
≤ 1.35 kV
125 A (gL (AC))

... 277 ST
II / T2
277 V AC
385 V AC
20 kA
≤ 1.35 kV
≤ 1.8 kV

... 347 ST
II / T2
347 V AC
440 V AC
20 kA
≤ 1.5 kV
≤ 2.2 kV

... 480 ST
II / T2
480 V AC
580 V AC
15 kA
≤ 2.1 kV
≤ 2.5 kV
125 A (gL)

17.7 mm / 52.4 mm / 54.5 mm
-40 °C ... 80 °C
IP20
PA 6.6
V0
IEC 61643-1 / DIN EN 61643-11 / DIN EN 61643-11/A11 /
UL 1449 / IEEE C62.1 / C62.34 / C62.45

17.7 mm / 52.4 mm / 54.5 mm
-40 °C ... 80 °C
IP20
PA 6.6
V0
IEC 61643-1 / EN 61643-11/A11 / NF C61-740

Ordering data

Ordering data

Type

Order No.

Pcs. /
Pkt.

2800738
2800739
2800740

10
10
10

Type

Order No.

Pcs. /
Pkt.

VAL-US 277 ST
VAL-US 347 ST
VAL-US 480 ST

2800741
2800742
2800743

10
10
10

VALVETRAB surge protection plug
60 V AC
120 V AC
240 V AC
277 V AC
347 V AC
480 V AC

VAL-US 60 ST
VAL-US 120 ST
VAL-US 240 ST

Accessories

Accessories

VALVETRAB, base element for 4-wire systems, L1, L2, L3, PEN,
for individual assembly with VAL-MS...ST
with remote indication contact
3L-PEN
without remote indication contact
3L-PEN
VALVETRAB, base element for 3-wire systems, L1, L2, PEN, for
individual assembly with VAL-MS...ST

VAL-MS/3+0-BE/FM
VAL-MS/3+0-BE

2881803
2881816

1
1

VAL-MS/3+0-BE/FM
VAL-MS/3+0-BE

2881803
2881816

1
1

with remote indication contact
without remote indication contact
VALVETRAB, single-position base element
with remote indication contact
without remote indication contact

VAL-MS/2+0-BE/FM
VAL-MS/2+0-BE

2805321
2804584

1
1

VAL-MS/2+0-BE/FM
VAL-MS/2+0-BE

2805321
2804584

1
1

VAL-MS BE/FM
VAL-MS BE

2817738
2817741

10
10

VAL-MS BE/FM
VAL-MS BE

2817738
2817741

10
10

2L-GND
2L - PEN

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

47

Surge protection and interference filters
Surge protection for the power supply unit
Type 2 surge arresters
VALVETRAB MS 65/80 kA performance class
– Multi-channel type 2 arrester
– Type 2 seamless plug-in surge arrester
– Secure hold of connectors in the event of
high lightning current loads and strong vibration thanks to new latching
– Disconnect device on each individual connector
– Optical, mechanical status indication for
the individual arresters
– With or without floating remote indication contact
– Mechanical keying of all slots
– Connectors can be checked with
CHECKMASTER

Notes:

H

For certifications, see page 154

W

D

5-conductor system; L1, L2, L3, N, PE

Total width 71.2 mm

12

14

/ PE

/ PE

11 FM

L1

L2

L3

N

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN

.. 385/65
II / T2
240 V AC (230/400 V AC ...
240/415 V AC)

.. 385/80
II / T2
240 V AC (230/400 V AC ...
240/415 V AC)

L-N / N-PE / L-PEN

385 V AC / 264 V AC / -

385 V AC / 264 V AC / -

L-N / N-PE / L-PEN

30 kA / 40 kA / -

40 kA / 40 kA / -

L-N / N-PE / L-PEN
L-N / N-PE / L-PEN

65 kA / 80 kA / ≤ 1.25 kV / ≤ 0.5 kV / -

80 kA / 80 kA / ≤ 1.25 kV / ≤ 0.5 kV / -

L-N / N-PE / L-PEN

≤ 1.8 kV / ≤ 1.7 kV / -

≤ 2 kV / ≤ 1.7 kV / -

L-N / N-PE / L-PEN
Backup fuse max. in acc. with IEC
Immunity to short-circuiting (with max. backup fuse) IP

≤ 25 ns / ≤ 100 ns / -

Maximum continuous operating voltage UC
Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Residual voltage at 5 kA
Protection level UP
Response time tA

General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current
Min. operational current

≤ 25 ns / ≤ 100 ns / 250 A (gL/gG)
25 kA

71.2 mm / 99 mm / 77.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)
5 mA (5 V)

Ordering data
Description
VALVETRAB MS
with remote indication contact
without remote indication contact
VALVETRAB MS
with remote indication contact
without remote indication contact

Imax

UC

65 kA
65 kA
80 kA
80 kA

Pcs. /
Pkt.

Type

Order No.

385 V AC
385 V AC

VAL-MS 385/65/3+1-FM
VAL-MS 385/65/3+1

2920887
2920890

1
1

385 V AC
385 V AC

VAL-MS 385/80/3+1-FM
VAL-MS 385/80/3+1

2920968
2920971

1
1

2920308
2920353
2921307

10
10
10

Accessories
Replacement connector
For VAL-MS 385/65...
For VAL-MS 385/80...
Marking material

48

PHOENIX CONTACT

1L-N/PE
1L-N/PE
N-PE

VAL-MS 385/65 ST
VAL-MS 385/80 ST
F-MS 80 ST
ZBN 18 ..., see page 63

Surge protection and interference filters
Surge protection for the power supply unit
H
D

H
W

D

4-conductor system; L1, L2, L3, PEN

3-conductor system; L, N, PE

Total width 53.4 mm
12
11

W

Total width 35.6 mm
14

PEN

12

PEN

14

/ PE

/ PE

11 FM

FM

L1

L2

L1

L3

Technical data

N

Technical data

.. 385/65
II / T2
240 V AC (230/400 V AC ...
240/415 V AC)

.. 385/80
II / T2
240 V AC (230/400 V AC ...
240/415 V AC)

.. 385/65
II / T2
240 V AC (230 V AC ... 240 V AC)

.. 385/80
II / T2
240 V AC (230 V AC ... 240 V AC)

- / - / 385 V AC

- / - / 385 V AC

385 V AC / 264 V AC / -

385 V AC / 264 V AC / -

- / - / 90 kA (all channels)

- / - / 120 kA (all channels)

30 kA / 40 kA / -

40 kA / 40 kA / -

- / - / 150 kA (all channels)
- / - / ≤ 1.2 kV

- / - / 200 kA (all channels)
- / - / ≤ 1.2 kV

65 kA / 80 kA / ≤ 1.2 kV / ≤ 0.5 kV / -

80 kA / 80 kA / ≤ 1.2 kV / ≤ 0.5 kV / -

- / - / ≤ 1.8 kV

- / - / ≤ 2 kV

≤ 1.8 kV / ≤ 1.7 kV / -

≤ 2 kV / ≤ 1.7 kV / -

- / - / ≤ 25 ns

- / - / ≤ 25 ns
250 A (gL/gG)
25 kA

≤ 25 ns / ≤ 100 ns / -

≤ 25 ns / ≤ 100 ns / 250 A (gL/gG)
25 kA

53.4 mm / 99 mm / 77.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)
5 mA (5 V)

35.6 mm / 99 mm / 77.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)
5 mA (5 V)

Ordering data

Ordering data

Type

Order No.

VAL-MS 385/65/3+0-FM
VAL-MS 385/65/3+0

2921006
2921019

VAL-MS 385/80/3+0-FM
VAL-MS 385/80/3+0

2921080
2921093

Pcs. /
Pkt.

Order No.

1
1

VAL-MS 385/65/1+1-FM
VAL-MS 385/65/1+1

2921242
2921255

1
1

1
1

VAL-MS 385/80/1+1-FM
VAL-MS 385/80/1+1

2921284
2921297

1
1

2920308
2920353
2921307

10
10
10

Accessories
VAL-MS 385/65 ST
VAL-MS 385/80 ST
ZBN 18 ..., see page 63

Pcs. /
Pkt.

Type

Accessories
2920308
2920353

10
10

VAL-MS 385/65 ST
VAL-MS 385/80 ST
F-MS 80 ST
ZBN 18 ..., see page 63

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

49

Surge protection and interference filters
Surge protection for the power supply unit
Surge protection for special
applications

H

H

– Universal pluggability
– Also suitable for industry solutions, e.g.,
in the rail and telecommunications sectors
– Thermal disconnect device for each individual connector
– Optical, mechanical status indication for
the individual arresters
– With or without floating remote indication contact
– Mechanical keying of all slots
– Connectors can be checked with
CHECKMASTER

D

W

For nominal voltages up to 48 V DC

For nominal voltages up to 48 V AC

Total width 17.5 mm

Notes:

W

D

Total width 35.6 mm

L

For certifications, see page 154

12

12

14

1

N / PEN

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC
Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Residual voltage at 5 kA
Protection level UP
Response time tA
Backup fuse max. in acc. with IEC
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

AC/DC

Technical data

I, II / T1, T2
60 V AC/DC
75 V AC / 100 V DC
12.5 kA
30 kA
≤ 0.3 kV
≤ 0.4 kV
≤ 25 ns
160 A (gL/gG)
17.5 mm / 97 mm / 77.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
V0
IEC 61643-11 / EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)

UC

2

Base element
240 V AC (415 V AC)
63 A (gL / gG)

Plug
II / T2
48 V AC (5 V...48 V AC)
75 V AC / 100 V DC
10 kA
20 kA
≤ 350 V
≤ 1.4 kV
≤ 100 ns
63 A (gL / gG)

35.6 mm / 97 mm / 51.5 mm
1 ... 35 mm² / 1 ... 25 mm² / 18 - 2
-40 °C ... 80 °C
V0
IEC 61643-1 / DIN EN 61643-11 / DIN EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V
1.5 A AC (250 V AC) / 1 A DC (30 V DC)

Ordering data
Description

14

11 FM

11 FM

Ordering data

Type

Order No.

VAL-MS-T1/T2 48/12.5/1+0-FM
VAL-MS-T1/T2 48/12.5/1+0

2801240
2801241

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

VAL-MS 75 VF ST

2805318

10

2800246

1

VALVETRAB-MS, varistor-based lightning arrester
with remote indication contact
without remote indication contact
Protective plug, for inserting in base element

75 V AC
75 V AC

1
1

75 V AC
Base element, for individual assembly with protective plugs
with remote indication contact

VAL-MS/2+0-BE/FM/S2

Accessories

Accessories

Replacement connector
L-N / L-PEN
Labeling material

50

PHOENIX CONTACT

VAL-MS-T1/T2 48/12.5 ST
ZBN 18 ..., see page 63

2801242

10
ZBN 18 ..., see page 63

Surge protection and interference filters
Surge protection for the power supply unit
Surge protection for use in wind
power plants

H

H

– For power supplies with higher supply
voltages
– Other solutions for power supplies
UN ≥ 400 V available on request
– Universal pluggability
– Thermal disconnect device for each individual connector
– Optical, mechanical status indication for
the individual arresters
– With or without floating remote indication contact
– Mechanical keying of all slots
– Connectors can be checked with
CHECKMASTER

W

D

W

D

Free of leakage current, for nominal voltages
up to 690 V AC, e.g., rotor protection for wind
power plants

Total width 35.6 mm

4-conductor system;
L1, L2, L3, PEN (554/960 V TN-C system)

Total width 53.4 mm
12

Notes:

14

12

11 FM

For certifications, see page 154

11

L

L1

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC
Nominal discharge surge current In (8/20) µs
L-PEN
Protection level UP
L-PEN
Response time tA
L-PEN
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

14

PEN

PEN

FM

L2

L3

Technical data

II / T2
690 V AC
800 V AC
15 kA
≤ 5 kV
≤ 100 ns
-

II / T2
554 V AC (554/960 V AC TN-C)
750 V AC
45 kA (all channels)
≤ 2.7 kV
≤ 25 ns

35.6 mm / 97 mm / 65.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
IP20
IEC 61643-1 / DIN EN 61643-11 / DIN EN 61643-11/A11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1 A DC (30 V DC)

53.4 mm / 99 mm / 65.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
IP20
IEC 61643-1 / DIN EN 61643-11 / DIN EN 61643-11/A11
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1 A DC (30 V DC)

Ordering data
Description

Type

VALVETRAB MS, for mounting on NS 35
with remote indication contact
without remote indication contact

VAL-MS 800/30 VF/FM

Ordering data
Order No.

2805402

Pcs. /
Pkt.

1

Pcs. /
Pkt.

Type

Order No.

VAL-MS 750/30/3+0-FM
VAL-MS 750/30/3+0

2920272
2920269

1
1

2920256

10

Accessories

Accessories

Replacement connector
1L-N/PE
Labeling material

VAL-MS 750/30-ST
F-MS 2200/30 ST
ZBN 18 ..., see page 63

2920256
2805392

10
10

VAL-MS 750/30-ST
ZBN 18 ..., see page 63

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

51

Surge protection and interference filters
Surge protection for the power supply unit
Type 2 surge arresters with RCD
Combi-RCD
– For 5-conductor systems; L1, L2, L3, N,
PE
– Combination of type 2 surge arrester and
RCD residual current circuit breaker
– Personal protection and device protection in a single device
– Type 2 seamless plug-in surge arrester
– Disconnect device on each individual connector
– Optical, mechanical status indication for
all protective connectors
– Residual current circuit breaker is not
triggered by magnetic influences caused
by discharge currents in the type 2 arrester
– Connectors can be checked with
CHECKMASTER

H

H
W

D

W

D

With selective RCD residual current circuit
breaker, 300 mA

Total width 121 mm

With selective RCD residual current circuit
breaker, 30 mA

Total width 121 mm

N 2 4 6

N 2 4 6

T

T

Notes:
For certifications, see page 154

PE

N 1 3 5

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

PE

N 1 3 5

Technical data

II / T2
240 V AC (230/400 V AC ... 240/415 V AC)

II / T2
240 V AC (230/400 V AC ... 240/415 V AC)

L-N / N-PE

350 V AC / 264 V AC

350 V AC / 264 V AC

L-N / N-PE

60 kA (all channels) / 20 kA

60 kA (all channels) / 20 kA

L-N / N-PE
L-N / N-PE

90 kA (all channels) / 30 kA
≤ 1.2 kV / ≤ 0.3 kV

90 kA (all channels) / 30 kA
≤ 1.2 kV / ≤ 0.3 kV

L-N / N-PE

≤ 2 kV / ≤ 2 kV

≤ 2 kV / ≤ 2 kV

L-N / N-PE

≤ 25 ns / ≤ 100 ns

≤ 25 ns / ≤ 100 ns

121 mm / 90 mm / 76 mm
4 ... 16 mm² / 4 ... 16 mm² / 12 - 4
-25 °C ... 40 °C
V0
IEC 61643-1 / EN 61643-11 / IEC 61008-1 /
IEC 61008-1/A11 / IEC 61008-2-1 / IEC 60947-3

121 mm / 90 mm / 76 mm
4 ... 16 mm² / 4 ... 16 mm² / 12 - 4
-25 °C ... 40 °C
V0
IEC 61643-1 / EN 61643-11 / IEC 61008-1 /
IEC 61008-1/A11 / IEC 61008-2-1 / IEC 60947-3

A selective
40 A
300 mA
630 A
630 A
6 kV (1.2/50 µs)
10 kA Back-up fuse: 63 A
≤ 300 ms
≤ 40 ms
20000
AC 23 A

A
40 A
30 mA
1.5 kA
2.5 kA
6 kV (1.2/50 µs)
10 kA Back-up fuse: 63 A
≤ 300 ms
≤ 40 ms
20000
AC 23 A

Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Residual voltage at 5 kA
Protection level UP
Response time tA
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
RCD data
Class
Nominal load current IL
Dimensioning error current
Rated making and breaking capacity Im
Rated residual making and breaking capacity I Δm
Surge withstand capability
Immunity to short-circuiting Inc
Tripping time for IΔn
Tripping time for 5xIΔn
Cycles, max.
Utilization category

Ordering data
Description

Ordering data

Type

Order No.

VAL-CP-RCD-3S/40/0.3/SEL

2808001

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

VALVETRAB compact with RCD
1
VAL-CP-RCD-3S/40/0.03

Accessories

2882802

1

2882718
2882734

10
10

Accessories

Replacement connector
L-N / L-PEN
N-PE

52

PHOENIX CONTACT

VAL-CP-350-ST-GY
VAL-CP-N/PE-350-ST-GY

2882718
2882734

10
10

VAL-CP-350-ST-GY
VAL-CP-N/PE-350-ST-GY

Surge protection and interference filters
Surge protection for the power supply unit
Type 2 surge arresters for 60 mm
system technology
Combi-MCB
– Combinations of type 2 arresters with integrated arrester backup fuse
– For 60 mm system technology
– Tool-free mounting on 5 and 10 mm busbars
– Signaling to monitoring systems via remote indication contact in the event of an
error
– Surge-proof arrester backup fuse tailored
to type 2 arresters
– Type 2 seamless plug-in surge arrester
– Disconnect device on each individual connector
– Optical, mechanical status indication for
the individual arresters
– Connectors can be checked with
CHECKMASTER

H

H
D

W

W

D

5-conductor system; L1, L2, L3, N, PE

4-conductor system; L1, L2, L3, PEN

Total width 54 mm

Total width 54 mm
L1

L2

L3

12

L1

14

L2

L3

11 FM

Notes:

12

14

11 FM

PE

For certifications, see page 154

PEN

N

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

Technical data

II / T2
240 V AC (230/400 V AC ... 240/415 V AC)

II / T2
240 V AC (230/400 V AC ... 240/415 V AC)

L-N / N-PE / L-PEN

350 V AC / 264 V AC / -

- / - / 350 V AC

L-N / N-PE / L-PEN

60 kA (all channels) / 20 kA / -

- / - / 60 kA (all channels)

L-N / N-PE / L-PEN
L-N / N-PE / L-PEN

75 kA (all channels) / 40 kA / ≤ 1.8 kV / ≤ 0.25 kV / -

- / - / 75 kA (all channels)
- / - / ≤ 1.8 kV

L-N / N-PE / L-PEN

≤ 2.5 kV / ≤ 1.5 kV / -

- / - / ≤ 2.5 kV

L-N / N-PE / L-PEN
Backup fuse max. in acc. with IEC
Immunity to short-circuiting (with max. backup fuse) IP

≤ 25 ns / ≤ 100 ns / (Not required)
25 kA

- / - / ≤ 25 ns
(Not required)
25 kA

Rated surge current resistance Ipk
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

52 kA

52 kA

54 mm / 220 mm / 110 mm
2.5 ... 25 mm² / 2.5 ... 16 mm² / 12 - 4
-25 °C ... 60 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC (ohmic) / 0.2 A DC (ohmic)

54 mm / 220 mm / 110 mm
2.5 ... 25 mm² / 2.5 ... 16 mm² / 12 - 4
-25 °C ... 60 °C
V0
IEC 61643-1 / EN 61643-11 / EN 61643-11/A11
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 125 V DC
1 A AC (ohmic) / 0.2 A DC (ohmic)

Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Residual voltage at 5 kA
Protection level UP
Response time tA

Ordering data
Description

Type

Ordering data
Order No.

Pcs. /
Pkt.

Pcs. /
Pkt.

Type

Order No.

VAL-CP-MOSO 60-3C-FM

2804416

1

2882718

10

VALVETRAB compact
VAL-CP-MOSO 60-3S-FM

2804403

1

Accessories

Accessories

Replacement connector
L-N / L-PEN
N-PE
Marking material

VAL-CP-350-ST-GY
VAL-CP-N/PE-350-ST-GY
ZBF 12 ..., see page 63

2882718
2882734

10
10

VAL-CP-350-ST-GY
ZBF 12 ..., see page 63

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

53

Surge protection and interference filters
Surge protection for the power supply unit
Type 2 surge arresters with integrated
backup fuse
Combi-MCB
– Combinations of type 2 arresters with integrated arrester backup fuse
– Overload of the surge protection results
in all-pole disconnection from the mains
– Signaling to monitoring systems via remote indication contact in the event of an
error
– Surge-proof arrester backup fuse tailored
to type 2 arresters
– Type 2 seamless plug-in surge arrester
– Disconnect device on each individual connector
– Optical, mechanical status indication for
the individual arresters
– Connectors can be checked with
CHECKMASTER

Notes:

H

For certifications, see page 154

D

W

5-conductor system; L1, L2, L3, N, PE

Total width 131.5 mm
14
N

L1

L2

L3

12

11 FM

IN

PE

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

II / T2
240 V AC (230/400 V AC ... 240/415 V AC)
L-N / N-PE / L-PEN

350 V AC / 264 V AC / -

L-N / N-PE / L-PEN

60 kA (all channels) / 20 kA / -

L-N / N-PE / L-PEN
L-N / N-PE / L-PEN

90 kA (all channels) / 30 kA / ≤ 1.3 kV / ≤ 0.5 kV / -

L-N / N-PE / L-PEN

≤ 2.5 kV / ≤ 1.7 kV / -

L-N / N-PE / L-PEN
Backup fuse max. in acc. with IEC
Immunity to short-circuiting (with max. backup fuse) IP

≤ 25 ns / ≤ 100 ns / (Not required)
25 kA

Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Residual voltage at 5 kA
Protection level UP
Response time tA

General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards

131.5 mm / 101 mm / 76 mm
2.5 ... 25 mm² / 2.5 ... 16 mm² / 12 - 4
-25 °C ... 60 °C
V0
IEC 61643-1 / EN 61643-11 / IEC 60364-4-443 /
IEC 60364-5-534
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 250 V DC
2 A AC / 50 mA DC

Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

Ordering data
Description

Pcs. /
Pkt.

Type

Order No.

VAL-CP-MCB-3S-350/40/FM

2882750

1

2882718
2882734

10
10

VALVETRAB compact, with an arrester backup fuse

Accessories
Replacement connector
L-N / L-PEN
N-PE

54

PHOENIX CONTACT

VAL-CP-350-ST-GY
VAL-CP-N/PE-350-ST-GY

Surge protection and interference filters
Surge protection for the power supply unit
H

H
W

D

W

D

4-conductor system; L1, L2, L3, PEN

3-conductor system; L, N, PE

Total width 114 mm

Total width 72 mm
14

L1

L2

12

14
N

11 FM

L3

L1

IN

IN

PE

PE

Technical data

Technical data

II / T2
240 V AC (230/400 V AC ... 240/415 V AC)

II / T2
240 V AC (230/400 V AC ... 240/415 V AC)

- / - / 350 V AC

350 V AC / 264 V AC / -

- / - / 60 kA (all channels)

20 kA / 20 kA / -

- / - / 90 kA (all channels)
- / - / ≤ 1.3 kV

30 kA / 30 kA / ≤ 1.3 kV / ≤ 0.5 kV / -

- / - / ≤ 2.5 kV

≤ 2.5 kV / ≤ 1.7 kV / -

- / - / ≤ 25 ns
(Not required)
25 kA

≤ 25 ns / ≤ 100 ns / (Not required)
25 kA

114 mm / 101 mm / 76 mm
2.5 ... 25 mm² / 2.5 ... 16 mm² / 12 - 4
-25 °C ... 60 °C
V0
IEC 61643-1 / EN 61643-11 / IEC 60364-4-443 /
IEC 60364-5-534
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 250 V DC
2 A AC / 50 mA DC

72 mm / 101 mm / 76 mm
2.5 ... 25 mm² / 2.5 ... 16 mm² / 12 - 4
-25 °C ... 60 °C
V0
IEC 61643-1 / EN 61643-11 / IEC 60364-4-443 /
IEC 60364-5-534
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 250 V DC
2 A AC / 50 mA DC

Ordering data

Ordering data

Type

Order No.

VAL-CP-MCB-3C-350/40/FM

2882776

Pcs. /
Pkt.

1

Accessories
VAL-CP-350-ST-GY

12

11 FM

Pcs. /
Pkt.

Type

Order No.

VAL-CP-MCB-1S-350/40/FM

2882763

1

2882718
2882734

10
10

Accessories
2882718

10

VAL-CP-350-ST-GY
VAL-CP-N/PE-350-ST-GY

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

55

Surge protection and interference filters
Surge protection for the power supply unit
Type 3 device protection
MAINS-PLUGTRAB

H

H

– For single and multi-phase power supply
units
– Rail-mountable module
– Comprising base element and connector
– With floating remote indication contact
– Optical signaling of disconnection via LED
– Tool-free connector replacement
– Connectors can be checked with
CHECKMASTER

W

D

W

D

5-conductor system; L1, L2, L3, N, PE

3-conductor system; L, N, PE

Notes:
For certifications, see page 154

Total width 35.4 mm

Total width 17.7 mm

N
3

L1

IN
L2

L

12
2

1
N
L1
L2
L3

5

6

4

11
J

5

6

L

12

OUT

IN

OUT

7

8

N

N

1

2

PE

3

4 PE

9
L3

10
11

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

AC/DC

Nominal load current IL
Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Combined surge UOC
Protection level UP

L-N/L(N)-PE

26 A (30 °C)
1.5 kA (per channel)
10 kA (N-PE)
4 kV
≤ 1.2 kV / ≤ 1.5 kV

Response time tA

L-N/L(N)-PE

≤ 25 ns / ≤ 100 ns

Backup fuse max. in acc. with IEC
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards

Technical data

... 230AC
III / T3
230 V AC (max. 240/415 V AC)
335 V AC (255 V AC / N-PE) / -

... 24AC
III / T3
24 V AC/DC
34 V AC /
44 V DC
26 A (30 °C)
1 kA
2 kV
≤ 180 V / -

... 60AC
III / T3
60 V AC
100 V AC /
95 V DC
26 A (30 °C)
2.5 kA
6.5 kA
4 kV
≤ 400 V / -

≤ 25 ns /
≤ 100 ns

≤ 25 ns /
≤ 100 ns

25 A (gL)
35.4 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
V0
IEC 61643-1 / EN 61643-11/A11
N/C contact
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
250 V
3 A AC

Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

Voltage UN

Type

... 230AC
III / T3
230 V AC
253 V AC / -

26 A (30 °C)
2.5 kA

26 A (30 °C)
3 kA
6 kV
≤ 1.1 kV /
≤ 1.5 kV
≤ 25 ns /
≤ 100 ns

6 kV
≤ 620 V /
≤ 850 V
≤ 25 ns /
≤ 100 ns
25 A (gL)

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
V0
IEC 61643-1 / EN 61643-11/A11 / UL 1449 ed. 3
N/C contact
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
250 V
3 A AC

Ordering data
Description

... 120AC
III / T3
120 V AC
150 V AC / -

Ordering data
Order No.

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

PT 2-PE/S-24AC/FM
PT 2-PE/S-60AC/FM
PT 2-PE/S-120AC/FM
PT 2-PE/S-230AC/FM

2800457
2800961
2856812
2858357

1
10
1
1

PT-BE/FM

2839282

10

PT MAIN-EST

2880736

10

MAINS-PLUGTRAB, consisting of a plug and base element
24 V AC/DC
60 V AC
120 V AC
230 V AC
48 V DC

PT 4-PE/S-230AC/FM

2882459

5

PT 4-PE/S-230AC-ST

2882462

5

MAINS-PLUGTRAB plug
24 V AC
60 V AC
120 V AC
230 V AC
48 V DC

Accessories

Accessories

PLUGTRAB base element, for mounting on NS 35

Grounding plug
Marking material

56

PHOENIX CONTACT

ZBF ..., see page 111

ZBF ..., see page 111

Surge protection and interference filters
Surge protection for the power supply unit
H

H
W

D

Replacement connector for 3-conductor
system; L, N, PE

Total width 17.7 mm

L

3-conductor system; L, N, PE/L, L, PE
(IT system)

3-conductor system, for single-phase DC
power supply units

Total width 17.7 mm

5

Total width 17.7 mm

5

L

6

OUT

1

2

3

4 PE

OUT

IN

PE

1

2

3

4 PE

Technical data
... 24AC
III / T3
24 V AC
34 V AC /
44 V DC
26 A (30 °C)
1 kA

... 60AC
III / T3
60 V AC
100 V AC /
95 V DC
26 A (30 °C)
2.5 kA

2 kV
≤ 180 V /
≤ 550 V
≤ 25 ns /
≤ 100 ns

4 kV
≤ 400 V /
≤ 700 V
≤ 25 ns /
≤ 100 ns

+

12

N

N
PE

2
6

11

J

12

IN

1
5

6

11
J

W

D

~

IN

12 (+)

~

11 (-) OUT

-

3

Technical data

4

Technical data

... 120AC
III / T3
120 V AC
150 V AC / -

... 230AC
III / T3
230 V AC
253 V AC / -

... 230AC
III / T3
230 V AC
275 V AC / -

... 48DC
III / T3
48 V DC
- / 60 V DC -

26 A (30 °C)
2.5 kA

26 A (30 °C)
3 kA

26 A (30 °C)
3 kA
8 kA
6 kV
≤ 1.2 kV / ≤ 1.5 kV

26 A (30 °C)
500 A
500 A
6 kV (for 12 Ω)
≤ 120 V / ≤ 120 V

≤ 25 ns / ≤ 100 ns

≤ 1 ns / ≤ 1 ns

25 A (gL/C)

25 A (gL)

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 75 °C
V0
IEC 61643-1 / EN 61643-11/A11
N/C contact
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
250 V
3 A AC/DC

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
V0
IEC 61643-1 / EN 61643-11/A11 / BS 6651 /
ANSI/IEEE C62.41 / EN 50082-2
N/C contact
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
250 V
3 A AC

6 kV
≤ 620 V /
≤ 850 V
≤ 25 ns /
≤ 100 ns
25 A (gL)

6 kV
≤ 1.1 kV /
≤ 1.5 kV
≤ 25 ns /
≤ 100 ns

17.7 mm / 45 mm / 52 mm
-40 °C ... 85 °C (non-EX)
V0
IEC 61643-1 / EN 61643-11/A11 / UL 1449
-

Ordering data
Type

Ordering data
Order No.

PT 2-PE/S- 24AC-ST
PT 2-PE/S- 60AC-ST
PT 2-PE/S-120AC-ST
PT 2-PE/S-230AC-ST

2839318
2839321
2839334
2839347

Pcs. /
Pkt.

10
10
10
10

Ordering data

Type

Order No.

PT 2-IT-230AC/FM

2805130

PT 2-IT-230AC-ST

2805127

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

PT 2+1-S-48DC/FM

2817958

10

2839648

10

PT-BE/FM

2839282

10

PT MAIN-EST

2880736

10

1

10
PT 2+1-S-48DC-ST

Accessories

PT-BE/FM

ZBF ..., see page 111

Accessories

2839282

10

Accessories

PT-BE/FM

2839282

10

PT MAIN-EST

2880736

10

ZBF ..., see page 111

ZBF ..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

57

Surge protection and interference filters
Surge protection for the power supply unit
Type 3 device protection
BLOCKTRAB and PRINTRAB

Notes:
For certifications, see page 154

BT-1S-230AC/... is device protection in
deep installation boxes (in acc. with DIN
49073), cable ducts, underfloor systems,
and termination devices.
– With double spring-cage terminal blocks
for tool-free conductor connection
– Side latches for easy fixing
– Optical/acoustic signaling of disconnection
For universal mounting, optical signaling

BT-SKT 230/A is device protection for
UP sockets.
– Independent of the switch range and pin
arrangement
– Is mounted on the socket insert
– For installation boxes as per DIN 49073
– Bridges provided for multiple combination
– Subsequent on-site installation possible
– Thermally monitored protective circuit
– Acoustic signaling of disconnection
– Signal deactivation by pulling the link under the socket cover
MAINS-PRINTRAB is device protection for installation in cable ducts and installation boxes.
– Two-piece design, consisting of
PRT-S-.../FM protective connector and
PRT-CD-AD1 flush-type base
– Optical and optical/audible signaling of
disconnection
– With floating remote indication contact
– Installation in range of switches with the
appropriate central plate possible
– Tool-free connector replacement

Total width 22.5 mm

J

230 V

!
J

PE

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC
Nominal load current IL
Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Combined surge UOC
Protection level UP
Response time tA
Backup fuse max. in acc. with IEC
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

L-N / L-PE

L-N / L-PE
L-N/L(N)-PE
L-N/L(N)-PE

... 230AC
III / T3
240 V AC
275 V AC / 440 V AC (4-conductor IT system)
16 A (30 °C)
3 kA
8 kA (> 100x 1 kA) / 6 kV
≤ 1.3 kV / ≤ 25 ns (L-N) / ≤ 100 ns (L, N-PE)
16 A (gL/C/B)
22.5 mm / 43 mm / 26.2 mm
0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
-30 °C ... 75 °C
V0
EN 61643-11/A11 / IEC 61643-1
-

Ordering data
Description

Voltage UN

Type

Order No.

BT-1S-230AC/O

2800625

Pcs. /
Pkt.

BLOCKTRAB, for universal mounting
240 V AC
SOCKETTRAB, device protection for installation socket inserts
230 V AC
MAINS-PRINTRAB, device protection plug with temperature monitoring and optical fault warning, as well as remote indication contact
120 V AC
230 V AC
MAINS-PRINTRAB, device protection plug with temperature monitoring, optical and acoustic fault warning and remote indicator contact
120 V AC
230 V AC
MAINS-PRINTRAB, flush-type base for installation in cable ducts
and flush-type boxes
230 V AC

Accessories
Central plate

58

PHOENIX CONTACT

1

Surge protection and interference filters
Surge protection for the power supply unit

For universal mounting, acoustic signaling

For mounting in flush-type sockets

For mounting in cable ducts and installation
boxes

Total width 22.5 mm

Total width 31.5 mm
L

L

J

230 V

!

PE
J

N

N

11
FM
12

PE

PE

Technical data

Technical data

... 230AC
III / T3
240 V AC
275 V AC / 440 V AC (4-conductor IT system)
16 A (30 °C)
3 kA
8 kA (> 100x 1 kA) / 6 kV
≤ 1.3 kV / ≤ 25 ns (L-N) / ≤ 100 ns (L, N-PE)
16 A (gL/C/B)

... 230AC
III / T3
230 V AC
335 V AC / 16 A (30 °C)
1.5 kA
4.5 kA / 4.5 kA
4 kV
≤ 1.3 kV / ≤ 1.5 kV
≤ 25 ns / ≤ 100 ns
16 A (gL / B)

22.5 mm / 43 mm / 26.2 mm
0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
-25 °C ... 75 °C
V0
EN 61643-11/A11 / IEC 61643-1

- ... - / - ... 1.5 mm² / -25 °C ... 75 °C
V0
EN 61643-11/A11 / IEC 61643-1

-

-

Ordering data
Order No.

Pcs. /
Pkt.

BT-1S-230AC/A

2803409

10

Accessories

Technical data
... 120AC
III / T3
120 V AC
150 V AC / 150 V AC
10 A (CSA)
1.5 kA
4.5 kA / 4.5 kA
4 kV
≤ 600 V / ≤ 800 V
≤ 25 ns / ≤ 100 ns

... 230AC
III / T3
230 V AC
253 V AC / 253 V AC
16 A (45°C)
1.5 kA
4.5 kA / 4.5 kA
4 kV
≤ 1.3 kV / ≤ 1.5 kV (at UOC)
≤ 25 ns / ≤ 100 ns
16 A (gL/C)

31.5 mm / 32.7 mm / 33 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-25 °C ... 75 °C
V0
IEC 61643-1 / EN 61643-11/A11
N/C contact
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 26 - 16
250 V AC
3A

Ordering data

Type

!

Ordering data

Type

Order No.

BT-SKT 230/A

2859343

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

PRT-S-120/FM
PRT-S-230/FM

2830618
2749686

10
10

PRT-S/A-120/FM
PRT-S/A-230/FM

2830605
2830621

1
10

PRT-CD-AD1

2749673

25

2830362

10

1

Accessories

Accessories
ZP-J/TAE/ST550 WH

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

59

Surge protection and interference filters
Surge protection for the power supply unit
Type 3 device protection
MAINTRAB
–
–
–
–

Attachment plug
For individual termination devices
With increased touch-proof protection
Optical signaling of the surge voltage
function via LED

Note: More information on other versions of MNT attachment plugs with combined protection for the power supply unit
and the interfaces of data/information technology can be found starting on page 126.
–
–
–
–

MNT-POWERLINE
For Powerline transmission systems
With adapted protective circuit
Optimized attenuation behavior
Optical signaling of the surge voltage
function via LED

Attachment plug

Attachment plug for Powerline transmission

Total width 56 mm

PE

Total width 63 mm

N

PE

L

N

L

Notes:
For certifications, see page 154

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC

Technical data

III / T3
230 V AC

III / T3
230 V AC

L-N / L-PE

275 V AC / 360 V AC
16 A (30 °C)

260 V AC / 260 V AC
16 A (30 °C)

L-N / L-PE

3 kA / 3 kA
4 kV

3 kA / 3 kA
6 kV

≤ 1.2 kV / ≤ 1.5 kV / ≤ 1.5 kV

≤ 1.1 kV / ≤ 1.5 kV / ≤ 1.5 kV

≤ 25 ns / ≤ 100 ns

≤ 25 ns / ≤ 100 ns

56 mm / 76.3 mm / 78.2 mm
-25 °C ... 75 °C
V0/HB
EN 61643-11/A11 / IEC 61643-1 / VDE 0620-1 /
SEK SS 428 08 34 / IEC 60884-1 / NEK-HD 195 S6

63 mm / 79 mm / 103.5 mm
-25 °C ... 75 °C
V0/HB
IEC 61643-1 / EN 61643-11/A11 / IEC 60884-1 /
DIN VDE 0620-1

Nominal load current IL
Nominal discharge surge current In (8/20) µs
Combined surge UOC
Protection level UP
L-N/N-PE/L-PE
Response time tA
L-N / L-PE
General data
Dimensions W / H / D
Temperature range
Inflammability class in acc. with UL 94
Test standards

Ordering data
Description

For countryspecific use in

Ordering data

Type

Order No.

MNT-1 D
MNT-1 D/WH
MNT-NET B/F
MNT-1 E
MNT-1 S/WH
MNT-1 CH II

2882200
2882213
2882226
2882239
2880862
2882255

Pcs. /
Pkt.

Type

Order No.

MNT-POWERLINE

2858001

Pcs. /
Pkt.

MAINTRAB, attachment plug with signal lamp for plugging into a
socket, for device protection
Black
D, A, NL
White
D, A, NL
Black
B, F, CZ, SVK, PL
Black
E, P
White
S, FIN, N
Black
CH
MAINTRAB-POWERLINE, attachment plug with signal lamp for
use in Powerline transmission systems
Black

60

D, A, NL, E, P

PHOENIX CONTACT

1
1
1
1
1
1

1

Surge protection and interference filters
Surge protection for the power supply unit
TRABTECH wiring bridges

– For combinations of lightning and surge
arresters
– In combination with other devices in the
installation distributor, such as residual
current circuit breakers and miniature circuit breakers
– Practical wiring of all common applications
– Single, three or four-phase versions with
various numbers of positions
– The rated cross section of the MPB bridge
metals is 16 mm2 per phase
– End covers are used to terminate and insulate individually cut bridges
Ordering data
Description

Nominal current IN

Wiring bridge, for modules with 17.5 mm connecting pitch,
1-phase
2-pos.
100 A
3-pos.
100 A
4-pos.
100 A
5-pos.
100 A
6-pos.
100 A
7-pos.
100 A
8-pos.
100 A
8-pos.
100 A
9-pos.
100 A
12-pos.
100 A
57-pos.
100 A
Wiring bridge, for modules with 17.5 mm connecting pitch,
3-phase
6-pos.
80 A
9-pos.
80 A
Wiring bridge, for modules with 17.5 mm connecting pitch,
4-phase
8-pos.
80 A
12-pos.
80 A
Wiring bridge, flexible, diameter 16 mm²,
fork-type cable lug on one side
200 mm
100 A (30 °C)
400 mm
100 A (30 °C)
600 mm
100 A (30 °C)

Type

Order No.

Pcs. /
Pkt.

MPB 18/1- 2
MPB 18/1- 3
MPB 18/1- 4
MPB 18/1- 5
MPB 18/1- 6
MPB 18/1- 7 BU
MPB 18/1- 8 BU
MPB 18/1- 8
MPB 18/1- 9
MPB 18/1-12
MPB 18/1-57

2809209
2809212
2809225
2817864
2748564
2856278
2858470
2748577
2748580
2748593
2809238

10
10
10
10
10
10
10
10
10
10
1

MPB 18/3- 6
MPB 18/3- 9

2809241
2809254

10
10

MPB 18/4- 8
MPB 18/4-12

2809283
2809296

10
10

MPB F200X16/ 1GS
MPB F400X16/ 1GS
MPB F600X16/ 1GS

2818339
2818342
2818355

1
1
1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

61

Surge protection and interference filters
Surge protection for the power supply unit
Feed-through terminal block

Notes:

H

For certifications, see page 154

D

– Biconnect feed-through terminal block
– For wiring mixed combinations of lightning and surge arresters
– As a system extension for FLASHTRAB
and VALVETRAB applications

W

Feed-through terminal block
Technical data
Electrical data
Maximum continuous operating voltage UC
Nominal current IN
Lightning test curr. Iimp (10/350) µs

500 V AC/DC
125 A (30 °C)
Peak value

General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards

100 kA
17.7 mm / 89.8 mm / 65.5 mm
35 ... 0.5 mm² / 0.5 ... 25 mm² / 20 - 2
-40 °C ... 85 °C
V0
IEC 60947-7-1 / IEC 60947-7-1 / IEC 60947-7-1

Ordering data
Description

Type

Order No.

Pcs. /
Pkt.

Feed-through terminal block
DK-BIC-35

2749880

1

Accessories
Marking material

ZBN 18 ..., see page 63

Equipotential bonding

49

160

59

– Equipotential bonding strip for main equipotential bonding according to
DIN VDE 0100
– As well as for lightning protection equipotential bonding in acc. with
DIN EN 62305
– Has a comb-shaped contact bar

Equipotential bonding strip

Ordering data
Description

Type

Order No.

PAS-1

2765615

Pcs. /
Pkt.

Equipotential bonding strip

62

PHOENIX CONTACT

1

Surge protection and interference filters
Surge protection for the power supply unit
Labeling material
P R I NT E D
F OR

YOU

– Flat zack marker strips
– Comprising five individual labels with
17.5 mm pitch.
– Can be labeled with CMS computer
marking system or by hand using B-STIFT

Ordering data
Description

Type

Order No.

Pcs. /
Pkt.

Marking labels
Can be labeled acc. to customer specifications
unprinted
L1, L2, L3, N, 
, , , , 
Zack marker sheet, flat, 120-section, can be separated

ZBN 18 CUS
ZBN 18:UNBEDRUCKT
ZBN 18,LGS:L1-N,ERDE
ZBN 18,LGS:ERDE

0825059
2809128
2749576
2749589

1
10
10
10

ZBFM 5 CUS
ZBFM 5/WH:UNBEDRUCKT

0825037
0803595

1
10

ZBF 12:UNBEDRUCKT

0809735

10

Can be labeled acc. to customer specifications
unprinted
Zack marker strip, flat, 5-section, without color print
5-section

TRABTECH housing

134

160

120

– For separate installation of surge protective devices
– Use in harsh environmental conditions at
the installation location
– Installation outdoors or indoors possible
– Aluminum housing equipped with two cable glands
– Supplied as standard: an NS 35/7.5 DIN
rail
– The DIN rail requires five part width sections of 17.5 mm each

IP65 protection class

Ordering data
Description

Type

Order No.

TG 40

2788896

Pcs. /
Pkt.

TRABTECH housing, for the isolated mounting of surge arresters

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1

63

Surge protection and interference filters
Renewable energy sources
Lightning and surge arresters for
PV systems
– Type 1 and type 2 consistent plug-in arresters
– Reliable contact, thanks to integrated rotating latch
– Optical, mechanical status indication for
the individual arresters
– With or without floating remote indication contact
– Mechanical keying of all slots

H

H
W

D

Type 1/2 arrester for insulated and
single-sided grounded PV applications

Notes:

W

D

Type 2 arrester for insulated and
single-sided grounded PV applications

For certifications, see page 154

Total width 53.4 mm

Total width 53.4 mm
12

14

12

11 FM

L+

L–

L+

Technical data
Electrical data
IEC category / EN type
Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Protection level UP
(L+) - (L-) / (L+/L-) - PE
Non-load voltage UOCSTC
Highest continuous voltage UCPV
Immunity to short-circuiting ISCPV
Response time tA:
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Housing material
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

L–

Technical data

... 1000 DC
PV- / PV-
15 kA
40 kA

... 600 DC
PV- / PV-
15 kA
40 kA

... 1000 DC
PV- /
15 kA
40 kA

... 600 DC
PV- /
15 kA
40 kA

≤ 3.5 kV / ≤ 3.5 kV
≤ 875 V DC
1050 V DC
300 A
≤ 25 ns

≤ 2.6 kV / ≤ 2.6 kV
≤ 600 V DC
720 V DC
300 A
≤ 25 ns

≤ 3.7 kV / ≤ 3.7 kV
≤ 970 V DC
1170 V DC
300 A
≤ 25 ns

≤ 2.7 kV / ≤ 2.7 kV
≤ 670 V DC
800 V DC
300 A
≤ 25 ns

53.4 mm / 99 mm / 65.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
IP20
PBT / PA
V0
EN 50539-11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 30 - 14
250 V AC / 30 V
1.5 A AC (250 V AC) / 1 A DC (30 V DC)

53.4 mm / 99 mm / 65.5 mm
1.5 ... 35 mm² / 1.5 ... 25 mm² / 15 - 2
-40 °C ... 80 °C
IP20
PBT / PA
V0
EN 50539-11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 30 - 14
250 V AC / 30 V
1.5 A AC (250 V AC) / 1 A DC (30 V DC)

Ordering data

Ordering data

Description

Type

Order No.

VALVETRAB-MS
with remote indication contact
without remote indication contact
with remote indication contact
without remote indication contact

VAL-MS-T1/T2 1000DC-PV/2+V-FM
VAL-MS-T1/T2 1000DC-PV/2+V
VAL-MS-T1/T2 600DC-PV/2+V-FM
VAL-MS-T1/T2 600DC-PV/2+V

2801161
2801160
2801164
2801163

Pcs. /
Pkt.

1
1
1
1

VAL-MS-T1/T2 1000DC-PV-ST
VAL-MS-T1/T2 600DC-PV-ST

Labeling material

ZBN 18 ..., see page 63

PHOENIX CONTACT

Pcs. /
Pkt.

Type

Order No.

VAL-MS 1000DC-PV/2+V-FM
VAL-MS 1000DC-PV/2+V
VAL-MS 600DC-PV/2+V-FM
VAL-MS 600DC-PV/2+V

2800627
2800628
2800641
2800642

1
1
1
1

2800624
2800623

1
1

Accessories
Replacement connector
1000 V DC
600 V DC

64

14

11 FM

Accessories
2801162
2801165

1
1

VAL-MS 1000DC-PV-ST
VAL-MS 600DC-PV-ST
ZBN 18 ..., see page 63

Surge protection and interference filters
Set solutions
Set solution for building installation

– Surge protection set for powerful basic
protection
– Coordinated protective devices
– VAL-MS-T1/T2 lightning arrester for installation in the distribution
– Three device protection adapters (type 3)
for protecting the power supply
– Two of these are equipped with additional
signal line protection (TV/SAT or TAE)
– Cables and adapters are supplied as standard

Set solution with surge protection for TAE and
TV-SAT

Ordering data
Description

Type

Order No.

GEB-SET-T1/T2 TAE/TV-SAT

2801022

Pcs. /
Pkt.

Building set, consisting of:
1 x VAL-MS-T1/T2 (surge arrester),
1 x MNT-1D (device protection adapter),
1 x MNT-TV-SAT D (device and TV-SAT protective adapter),
1 x MNT-TAE D (device and TAE protective adapter),
2 x adapter F to TV (IEC) connector,
1 x KBL TV-SAT/150, 1 x KBL TV/150,
1 x KBL TAE/150 (connecting cable)

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1

65

Surge protection and interference filters
Set solutions
Surge protection for photovoltaic
systems

Notes:
For certifications, see page 154

– For insulated or grounded PV applications
up to 1000 V DC
– Pre-assembled protection solutions
– Suitable for DC applications such as PV
systems
– Type 1/2 universally plug-in capable lightning arresters and surge arresters
– Optical, mechanical status indication for
the individual arresters
– Mechanical keying of all slots
– Connectors can be checked with
CHECKMASTER

For insulated or grounded PV applications up
to 1000 V DC, with SUNCLIX

Total width 125 mm
L+

L+

OUT

IN

L–

L–

Technical data
Electrical data
IEC category / EN type
Lightning test curr. Iimp (10/350) µs
Peak value
Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Protection level UP
(L+) - (L-) / (L+/L-) - PE
Highest continuous voltage UCPV
Immunity to short-circuiting ISCPV
Response time tA:
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Housing material
Inflammability class in acc. with UL 94
Test standards
Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

PV- / PV-
5 kA
15 kA
40 kA
≤ 3.5 kV / ≤ 3.5 kV
1000 V DC
32 A DC
≤ 25 ns
125 mm / 200 mm / 122 mm
-30 °C ... 55 °C
IP65
Polycarbonate, glass-fiber-reinforced
V2 (housing/cover)
IEC 61439-2 / EN 61439-2 / prEN 50539-11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)

Ordering data
Description

Type

Order No.

Surge protection in IP65 housing, for photovoltaic systems up to
1000 V DC
(L+)-PE & (L-)-PE & (L+)-(L-)

PV-SET 1ST/1000DC/1MPP-SPD-SC

Pcs. /
Pkt.

2801529

1

2801162

1

Accessories
Replacement connector
VAL-MS-T1/T2 1000DC-PV-ST

66

PHOENIX CONTACT

Surge protection and interference filters
Set solutions

For two MPP trackers, up to 1000 V DC,
with SUNCLIX

For three MPP trackers, up to 1000 V DC,
with SUNCLIX

Total width 200 mm
L+

IN

For two solar strings, including a generator
disconnect

Total width 300 mm
L+

L+

IN

Total width 200 mm

LL+

L+

IN

IN

L- L+

IN

L- L+

L+

L-

IN

L+
L+

OUT

L+

L+

OUT

OUT

L- L+

OUT

L- L+

L-

OUT

OUT

L–

L–

L-

Technical data

Technical data

Technical data

PV- / PV-

PV- / PV-

PV- / PV-

5 kA
15 kA
40 kA

5 kA
15 kA
40 kA

5 kA
15 kA
40 kA

≤ 3.5 kV / ≤ 3.5 kV
1000 V DC
32 A DC (per MPP)
≤ 25 ns

≤ 3.5 kV / ≤ 3.5 kV
1000 V DC
32 A DC (per MPP)
≤ 25 ns

≤ 3.5 kV / ≤ 3.5 kV
1000 V DC
32 A DC
≤ 25 ns

200 mm / 200 mm / 122 mm
-30 °C ... 55 °C
IP65
Polycarbonate, glass-fiber-reinforced
V2 (housing/cover)
IEC 61439-2 / EN 61439-2 / prEN 50539-11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)

300 mm / 300 mm / 142 mm
-30 °C ... 55 °C
IP65
Polycarbonate, glass-fiber-reinforced
V2 (housing/cover)
IEC 61439-2 / EN 61439-2 / prEN 50539-11
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)

200 mm / 200 mm / 122 mm
-20 °C ... 40 °C
IP65
Polycarbonate, glass-fiber-reinforced
V2 (housing/cover)
prEN 50539-11 / EN 61439-2
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 30 V DC
1.5 A AC (250 V AC) / 1.5 A DC (30 V DC)

Ordering data

Ordering data

Type

Order No.

PV-SET 2ST/1000DC/2MPP-SPD-SC

2801317

Pcs. /
Pkt.

1

Accessories
VAL-MS-T1/T2 1000DC-PV-ST

Type

Ordering data
Order No.

PV-SET 3ST/1000DC/3MPP-SPD-SC

2801531

Pcs. /
Pkt.

1

Type

PV-SET 2ST/1000DC-SPD-SD-SC

Accessories
2801162

1

VAL-MS-T1/T2 1000DC-PV-ST

Order No.

Pcs. /
Pkt.

2801318

1

2801162

1

Accessories
2801162

1

VAL-MS-T1/T2 1000DC-PV-ST

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

67

Surge protection and interference filters
NEMA set solutions
Device protection for components

–
–
–
–
–
–
–
–

Protects AC power mains
50 kA direct lightning strike energy
Combination lightning arrester and TVSS
Revolutionary Arc Chopping Spark Gap
technology
Extinguishes up to 50 kA of follow current
Remote status contacts
Status LED lamps available
ETL listed to UL 1449, 3rd edition

120/240 V single/split phase system

N/GND

L1

120/208Y system

L2

N/GND

L1

Technical data
MCOV
Nominal voltage UN
Lightning test curr. Iimp (10/350) µs
Response time tA
Voltage Protection Rating (VPR)
L-L / L-PE
Short-circuit current rating (SCCR)
UL Type
Connection data solid / stranded / AWG
Error/status indicator
Temperature range
Dimensions
Test standards

W/H/D

L3

Technical data

275 V
< 240 V
50 kA (per mode)
≤ 25 ns

275 V
< 240 V
50 kA (per mode)
≤ 25 ns

1500 V / 900 V
50 kA
Type 2
10 ... 50 mm² / 16 ... 35 mm² / 6 - 1
Remote indicator contact
-40 °C ... 80 °C
400 mm / 500 mm / 210 mm
UL 1449 3rd edition, Sept. 2009 / IEC 60643-1 /
EN 61643-11
CAN/CSA-C22.2 No. 8

1500 V / 900 V
50 kA
Type 2
10 ... 50 mm² / 16 ... 35 mm² / 6 - 1
Remote indicator contact
-40 °C ... 80 °C
400 mm / 500 mm / 210 mm
UL 1449 3rd edition, Sept. 2009 / IEC 60643-1 /
EN 61643-11
CAN/CSA-C22.2 No. 8

Ordering data
Description

L2

Ordering data

Type

Order No.

IP66 / NEMA 4 cabinet

SYS N4 120/240S

2800705

IP66 / NEMA 4 cabinet with indicator lamps

SYS N4/I 120/240S

IP66 / NEMA 4X cabinet
IP66 / NEMA 4X cabinet with indicator lamps

Pcs. /
Pkt.

Pcs. /
Pkt.

Type

Order No.

1

SYS N4 120/208Y

2800704

1

2800710

1

SYS N4/I 120/208Y

2800709

1

SYS N4X 120/240S

2800715

1

SYS N4X 120/208Y

2800714

1

SYS N4X/I 120/240S

2800720

1

SYS N4X/I 120/208Y

2800719

1

SYSTEMTRAB arrester and TVSS system

68

PHOENIX CONTACT

Surge protection and interference filters
NEMA set solutions

277/480Y system

N/GND

L1

L2

240 V High-Leg Delta

L3

N/GND

L1

Technical data

L2

480 V Delta system

L3

N/GND

Technical data

L1

L2

L3

Technical data

- / 600 V (L-L) / 440 V (L-G)
< 277 V
50 kA (per mode)
≤ 25 ns

275 V
< 240 V
50 kA (per mode)
≤ 25 ns

- / 600 V (L-L) / 480 V (L-G)
< 480 V
50 kA (per mode)
≤ 25 ns

2500 V / 1500 V
50 kA
Type 2
10 ... 50 mm² / 16 ... 35 mm² / 6 - 1
Remote indicator contact
-40 °C ... 80 °C
400 mm / 500 mm / 210 mm
UL 1449 3rd edition, Sept. 2009 / IEC 60643-1 /
EN 61643-11
CAN/CSA-C22.2 No. 8

1500 V / 900 V
50 kA
Type 2
10 ... 50 mm² / 16 ... 35 mm² / 6 - 1
Remote indicator contact
-40 °C ... 80 °C
400 mm / 500 mm / 210 mm
UL 1449 3rd edition, Sept. 2009 / IEC 60643-1 / EN 61643-11 /

2500 V / 1500 V
50 kA
Type 2
10 ... 50 mm² / 16 ... 35 mm² / 6 - 1
Remote indicator contact
-40 °C ... 80 °C
400 mm / 500 mm / 210 mm
UL 1449 3rd edition, Sept. 2009 / IEC 60643-1 / EN 61643-11 /

CAN/CSA-C22.2 No. 8

CAN/CSA-C22.2 No. 8

Ordering data

Ordering data

Type

Order No.

SYS N4 277/480Y

2800703

SYS N4/I 277/480Y

Pcs. /
Pkt.

Ordering data

Type

Order No.

1

SYS N4 120/240HLD

2800706

2800708

1

SYS N4/I 120/240HLD

SYS N4X 277/480Y

2800713

1

SYS N4X/I 277/480Y

2800718

1

Pcs. /
Pkt.

Pcs. /
Pkt.

Type

Order No.

1

SYS N4 480D

2800707

1

2800711

1

SYS N4/I 480D

2800712

1

SYS N4X 120/240HLD

2800716

1

SYS N4X 480D

2800717

1

SYS N4X/I 120/240HLD

2800721

1

SYS N4X/I 480D

2800722

1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

69

Surge protection and interference filters
Surge protection for measurement and control technology

Intelligent and systematic surge protection – PLUGTRAB PT-IQ
The PLUGTRAB PT-IQ product range is
the first to offer predictive function monitoring for surge protective devices in the
context of measurement and control technology. Boasting a whole range of additional
features, the new surge protection system is
a real highlight from Phoenix Contact.
Always know what is happening – predictive monitoring
The individual components of the protective devices are permanently monitored.
When the performance limit has been
reached as a result of frequent surge voltages, this is indicated by the yellow status symbol. The arrester continues to function and
your system is still protected. However, replacement of the protective plug is recommended. This ensures you are informed
even earlier and can replace your surge protection before the protective plug is overloaded (red signal). Furthermore, if you use
the remote signaling option, you can check
how well your system is being protected
from anywhere and at any time.

70

PHOENIX CONTACT

Permanent and error-free installation
The PLUGTRAB PT-IQ minimizes the
amount of wiring required. This is made
possible by the DIN rail connector (TBUS),
which is easily clipped onto the DIN rail. A
controller handles the distribution of the
power supply and implements remote signaling of all connected surge protective devices via the TBUS. All you have to do then
is install the surge protective devices on the
TBUS – and you're done! The plug and base
element are coded to avoid installation errors during replacement.
Limitless extension
The controller monitors all arresters
which are connected to the controller via
the TBUS. You can bridge the TBUS across
DIN rails to monitor even more protective
devices. After 28 protective devices, an additional controller must be installed to supply voltage. Remote signaling can be performed from any controller in the system.

Other surge protective devices
PLUGTRAB PT are plug-in arresters without remote signaling, also with switching
variants for intrinsically safe signal circuits.
The multi-stage modular terminal blocks
in the TERMITRAB or LINETRAB product
ranges have a design width of just 6.2 mm
yet are able to offer protection for up to
four signal wires.
As they are installed directly on measuring sensors, the SURGETRAB screw connection modules are able to provide reliable
protection against transients even in EX-i
and Ex-d applications.
The products in the COMTRAB modular
range have been designed specifically for use
in marshalling distributors.

Surge protection and interference filters
Surge protection for measurement and control technology

Group message
Green: protective device OK
Yellow: performance limit reached,
replacement recommended
Red: protective device overloaded,
replace

Multi-level remote signaling
Connect the remote signaling to the controller that acts as a supply and remote
module (one-off connection operation).
The status is output according to the priority as red, yellow or green. This ensures you
always know what is happening and can always keep an eye on your system's protection.

TBUS DIN rail connector
The DIN rail connector (TBUS) supplies
voltage to the protection modules and forwards the status of each individual arrester
to the controller. You benefit from the reduced wiring costs and can implement surge
protection quickly without errors.

Narrow arresters
The narrow TERMITRAB modular
terminal blocks have a design width of just
6.2 mm. Some offer multi-stage protective
circuits for Ex and non-Ex applications.

Special systems
Implement protection in the field directly
at the measuring sensor with SURGETRAB
screw connection modules.

Versions for terminal strips
COMTRAB modular type protective devices are used for highly compressed cable
networks like those found in marshalling
distributors, for example.

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

71

Surge protection and interference filters
Surge protection for measurement and control technology
PLUGTRAB PT-IQ with screw
connection

H

H

W

D

Controller for supply and remote signaling

Total width 17.7 mm

Double conductor (loop), floating,
9/10 connection grounded directly

Total width 17.7 mm

SPD

– Surge protection system
– Multi-level state monitoring
– Collective message about supply and remote module
– Multi-level, floating remote signaling
– System supplied via DIN rail bus
– Up to 28 protection modules per supply
module
– Maximum ease of maintenance thanks to
the two-piece design
– Plugs are coded
– Impedance-neutral disconnection of plug
for maintenance purposes
– Base element remains an integral part of
the installation
– Base element with screw connection
technology

W

D

Power
8

FM

7

8

11

12

9

10

3

4

Notes:
10 FM

For certifications, see page 154
12 FM
3

4

DC + 1

2

DC +

DC – 5

6

DC –

Technical data
Electrical data
IEC category / EN type

Technical data

DC/AC

Maximum continuous operating voltage UC
Lightning test curr. Iimp (10/350) µs
Nominal current IN

Per path

max. 130 mA (24 V DC)

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 12DC
C1 / C2 / C3 /
D1
15 V DC /
10 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 48DC
C1 / C2 / C3 /
D1
53 V DC /
37 V AC
2.5 kA
300 mA (Up to
45°C)

Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core

-

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

-

Core-Ground

-

≤ 25 V
(C3 - 25 A)
≤ 600 V (C1 1 kV/500 A)
1.2 Ω

≤ 35 V
(C3 - 25 A)
≤ 600 V (C1 1 kV/500 A)
1.2 Ω

≤ 55 V
(C3 - 25 A)
≤ 600 V (C1 1 kV/500 A)
1.2 Ω

≤ 90 V
(C3 - 25 A)
≤ 600 V (C1 1 kV/500 A)
1.2 Ω

Resistance per path
General data
Dimensions W / H / D
Connection data solid/stranded with ferrule/ AWG

-

Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

-40 °C ... 70 °C
IP20
V0
EN 61000-6-2 / EN 61000-6-2/A1 / EN 61000-6-3

Remote indication contact
Connection data solid/AWG
Max. operating voltage
Max. operating current

2 x N/C contacts
0.2 ... 4 mm² / 24 - 14
30 V AC (50 - 60 Hz) / 50 V DC
1 A (up to 50°C) / 200 mA (up to 70°C)

17.7 mm / 91.1 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

17.7 mm / 91.1 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A1 / EN 61000-6-2 /
EN 61000-6-2/A1 / EN 61000-6-3
Via TBUS
-

Ordering data
Description

Voltage UN

PLUGTRAB supply module, consisting of a plug, base element,
and DIN rail bus
24 V DC
MCR-PLUGTRAB, consisting of a plug, base element, and DIN rail
bus
5 V DC
12 V DC
24 V DC
48 V DC

Ordering data

Type

Order No.

PT-IQ-PTB-UT

2800768

Pcs. /
Pkt.

Order No.

PT-IQ-1X2-5DC-UT
PT-IQ-1X2-12DC-UT
PT-IQ-1X2-24DC-UT
PT-IQ-1X2-48DC-UT

2800791
2800793
2800976
2800978

1
1
1
1

2800770
2800771
2800772
2800773

1
1
1
1

1

Accessories
Replacement connector
5 V DC
12 V DC
24 V DC
48 V DC
Marking material

72

PHOENIX CONTACT

PT-IQ-PTB-P
ZB 6, see page 111

Pcs. /
Pkt.

Type

Accessories

2800989

1

PT-IQ-1X2-5DC-P
PT-IQ-1X2-12DC-P
PT-IQ-1X2-24DC-P
PT-IQ-1X2-48DC-P
ZB 6, see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
H

H
W

D

H
W

D

Double conductor (loop), floating,
9/10 connection grounded via gas-filled surge
arrester

Total width 17.7 mm

W

D

2-wire with common reference potential,
9/10 connection grounded directly

2-wire with common reference potential,
9/10 connection grounded via gas-filled surge
arrester

Total width 17.7 mm

Total width 17.7 mm

7

8

7

8

7

8

11

12

11

12

11

12

9

10

9

10

9

10

3

4

3

4

3

4

Technical data

Technical data

Technical data

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 12DC
C1 / C2 / C3 /
D1
15 V DC /
10 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 48DC
C1 / C2 / C3 /
D1
53 V DC /
37 V AC
2.5 kA
300 mA (Up to
45°C)

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 12DC
C1 / C2 / C3 /
D1
15 V DC /
4 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 48DC
C1 / C2 / C3 /
D1
53 V DC /
37 V AC
2.5 kA
300 mA (Up to
45°C)

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 12DC
C1 / C2 / C3 /
D1
15 V DC /
10 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
2.5 kA
1000 mA (Up
to 45°C)

... 48DC
C1 / C2 / C3 /
D1
53 V DC /
37 V AC
2.5 kA
300 mA (Up to
45°C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

≤ 25 V
(C3 - 25 A)
≤ 900 V (C1 1 kV/500 A)
1.2 Ω

≤ 35 V
(C3 - 25 A)
≤ 900 V (C1 1 kV/500 A)
1.2 Ω

≤ 55 V
(C3 - 25 A)
≤ 900 V (C1 1 kV/500 A)
1.2 Ω

≤ 90 V
(C3 - 25 A)
≤ 900 V (C1 1 kV/500 A)
1.2 Ω

≤ 25 V
(C3 - 25 A)
1.2 Ω

≤ 35 V
(C3 - 25 A)
1.2 Ω

≤ 55 V
(C3 - 25 A)
1.2 Ω

≤ 90 V
(C3 - 25 A)
1.2 Ω

≤ 720 V (C1 1 kV/500 A)
1.2 Ω

≤ 750 V (C1 1 kV/500 A)
1.2 Ω

≤ 800 V (C1 1 kV/500 A)
1.2 Ω

≤ 750 V (C1 1 kV/500 A)
1.2 Ω

17.7 mm / 91.1 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

17.7 mm / 91.1 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

17.7 mm / 91.1 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A1 / EN 61000-6-2 /
EN 61000-6-2/A1 / EN 61000-6-3
Via TBUS
-

-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A1 / EN 61000-6-2 /
EN 61000-6-2/A1 / EN 61000-6-3
Via TBUS
-

-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A1 / EN 61000-6-2 /
EN 61000-6-2/A1 / EN 61000-6-3
Via TBUS
-

Ordering data

Ordering data

Ordering data

Type

Order No.

PT-IQ-1X2+F-5DC-UT
PT-IQ-1X2+F-12DC-UT
PT-IQ-1X2+F-24DC-UT
PT-IQ-1X2+F-48DC-UT

2800792
2800975
2800977
2800979

Pcs. /
Pkt.

1
1
1
1

Type

Order No.

PT-IQ-2X1-5DC-UT
PT-IQ-2X1-12DC-UT
PT-IQ-2X1-24DC-UT
PT-IQ-2X1-48DC-UT

2800778
2800780
2800787
2800789

Accessories
PT-IQ-1X2-5DC-P
PT-IQ-1X2-12DC-P
PT-IQ-1X2-24DC-P
PT-IQ-1X2-48DC-P
ZB 6, see page 111

Pcs. /
Pkt.

1
1
1
1

Order No.

PT-IQ-2X1+F-5DC-UT
PT-IQ-2X1+F-12DC-UT
PT-IQ-2X1+F-24DC-UT
PT-IQ-2X1+F-48DC-UT

2800779
2800781
2800788
2800790

1
1
1
1

2800774
2800775
2800776
2800777

1
1
1
1

Accessories
2800770
2800771
2800772
2800773

1
1
1
1

PT-IQ-2X1-5DC-P
PT-IQ-2X1-12DC-P
PT-IQ-2X1-24DC-P
PT-IQ-2X1-48DC-P
ZB 6, see page 111

Pcs. /
Pkt.

Type

Accessories
2800774
2800775
2800776
2800777

1
1
1
1

PT-IQ-2X1-5DC-P
PT-IQ-2X1-12DC-P
PT-IQ-2X1-24DC-P
PT-IQ-2X1-48DC-P
ZB 6, see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

73

Surge protection and interference filters
Surge protection for measurement and control technology
PLUGTRAB PT-IQ with push-in
connection technology

H

H

W

D

Controller for supply and remote signaling

Total width 17.7 mm

Double conductor (loop), floating,
9/10 connection grounded directly

Total width 17.7 mm

SPD

– Surge protection system
– Multi-level state monitoring
– Collective message about supply and remote module
– Multi-level, floating remote signaling
– System supplied via DIN rail bus
– Up to 28 protection modules per supply
module
– Maximum ease of maintenance thanks to
the two-piece design
– Plugs are coded
– Impedance-neutral disconnection of plug
for maintenance purposes
– Base element remains an integral part of
the installation
– Base element in push-in connection technology

W

D

Power
8

FM

7

8

11

12

9

10

3

4

Notes:
10 FM

For certifications, see page 154
12 FM
3

4

DC + 1

2

DC +

DC – 5

6

DC –

Technical data
Electrical data
IEC category / EN type

Technical data

DC/AC

Maximum continuous operating voltage UC
Lightning test curr. Iimp (10/350) µs
Nominal current IN

Per path

max. 130 mA (24 V DC)

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
1000 mA (up to
40 °C)

... 12DC
C1 / C2 / C3 /
D1
15 V DC /
10 V AC
2.5 kA
1000 mA (up to
40 °C)

... 24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
2.5 kA
1000 mA (up to
40 °C)

... 48DC
C1 / C2 / C3 /
D1
53 V DC /
37 V AC
2.5 kA
300 mA (up to
70°C)

Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core

-

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

-

Core-Ground

-

≤ 25 V
(C3 - 25 A)
≤ 600 V (C1 1 kV/500 A)
1.2 Ω

≤ 35 V
(C3 - 25 A)
≤ 600 V (C1 1 kV/500 A)
1.2 Ω

≤ 55 V
(C3 - 25 A)
≤ 600 V (C1 1 kV/500 A)
1.2 Ω

≤ 90 V
(C3 - 25 A)
≤ 600 V (C1 1 kV/500 A)
1.2 Ω

Resistance per path
General data
Dimensions W / H / D
Connection data solid/stranded with ferrule/ AWG

-

Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

-40 °C ... 70 °C
IP20
V0
EN 61000-6-2/A1 / EN 61000-6-3

Remote indication contact
Connection data solid/AWG
Max. operating voltage
Max. operating current

2 x N/C contacts
0.2 ... 4 mm² / 24 - 12
35 V AC (50 - 60 Hz) / 50 V DC
1 A (up to 50°C) / 200 mA (up to 70°C)

17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 70 °C
IP20
V0
IEC 61643-21/A2 / EN 61643-21/A1 / EN 61000-6-2/A1 /
EN 61000-6-3
Via TBUS
-

Ordering data
Description

Voltage UN

PLUGTRAB supply module, consisting of a plug, base element,
and DIN rail bus
24 V DC
MCR-PLUGTRAB, consisting of a plug, base element, and DIN rail
bus
5 V DC
12 V DC
24 V DC
48 V DC

Ordering data

Type

Order No.

PT-IQ-PTB-PT

2801296

Pcs. /
Pkt.

Order No.

PT-IQ-1X2-5DC-PT
PT-IQ-1X2-12DC-PT
PT-IQ-1X2-24DC-PT
PT-IQ-1X2-48DC-PT

2801251
2801253
2801255
2801257

1
1
1
1

2800770
2800771
2800772
2800773

1
1
1
1

1

Accessories
Replacement connector
5 V DC
12 V DC
24 V DC
48 V DC
Marking material

74

PHOENIX CONTACT

PT-IQ-PTB-P
ZB 6, see page 111

Pcs. /
Pkt.

Type

Accessories

2800989

1

PT-IQ-1X2-5DC-P
PT-IQ-1X2-12DC-P
PT-IQ-1X2-24DC-P
PT-IQ-1X2-48DC-P
ZB 6, see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
H

H
W

D

H
W

D

Double conductor (loop), floating,
9/10 connection grounded via gas-filled surge
arrester

Total width 17.7 mm

W

D

2-wire with common reference potential,
9/10 connection grounded directly

2-wire with common reference potential,
9/10 connection grounded via gas-filled surge
arrester

Total width 17.7 mm

Total width 17.7 mm

7

8

7

8

7

8

11

12

11

12

11

12

9

10

9

10

9

10

3

4

3

4

3

4

Technical data

Technical data

Technical data

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
1000 mA (up to
40 °C)

... 12DC
C1 / C2 / C3 /
D1
15 V DC /
10 V AC
2.5 kA
1000 mA (up to
40 °C)

... 24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
2.5 kA
1000 mA (up to
40 °C)

... 48DC
C1 / C2 / C3 /
D1
53 V DC /
37 V AC
2.5 kA
300 mA (up to
70°C)

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
1000 mA (up to
40 °C)

... 12DC
C1 / C2 / C3 /
D1
15 V DC /
4 V AC
2.5 kA
1000 mA (up to
40 °C)

... 24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
2.5 kA
1000 mA (up to
40 °C)

... 48DC
C1 / C2 / C3 /
D1
53 V DC /
37 V AC
2.5 kA
300 mA (up to
70°C)

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
1000 mA (up to
40 °C)

... 12DC
C1 / C2 / C3 /
D1
15 V DC /
10 V AC
2.5 kA
1000 mA (up to
40 °C)

... 24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
2.5 kA
1000 mA (up to
40 °C)

... 48DC
C1 / C2 / C3 /
D1
53 V DC /
37 V AC
2.5 kA
300 mA (up to
70°C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

≤ 25 V
(C3 - 25 A)
≤ 900 V (C1 1 kV/500 A)
1.2 Ω

≤ 35 V
(C3 - 25 A)
≤ 900 V (C1 1 kV/500 A)
1.2 Ω

≤ 55 V
(C3 - 25 A)
≤ 900 V (C1 1 kV/500 A)
1.2 Ω

≤ 90 V
(C3 - 25 A)
≤ 900 V (C1 1 kV/500 A)
1.2 Ω

≤ 25 V
(C3 - 25 A)
1.2 Ω

≤ 35 V
(C3 - 25 A)
1.2 Ω

≤ 55 V
(C3 - 25 A)
1.2 Ω

≤ 90 V
(C3 - 25 A)
1.2 Ω

≤ 720 V (C1 1 kV/500 A)
1.2 Ω

≤ 750 V (C1 1 kV/500 A)
1.2 Ω

≤ 780 V (C3 25 A)
1.2 Ω

≤ 750 V (C1 1 kV/500 A)
1.2 Ω

17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

-40 °C ... 70 °C
IP20
V0
IEC 61643-21/A2 / EN 61643-21/A1 / EN 61000-6-2/A1 /
EN 61000-6-3
Via TBUS
-

-40 °C ... 70 °C
IP20
V0
IEC 61643-21/A2 / EN 61643-21/A1 / EN 61000-6-2/A1 /
EN 61000-6-3
Via TBUS
-

-40 °C ... 70 °C
IP20
V0
IEC 61643-21/A2 / EN 61643-21/A1 / EN 61000-6-2/A1 /
EN 61000-6-3
-

Ordering data

Ordering data

Ordering data

Type

Order No.

PT-IQ-1X2+F-5DC-PT
PT-IQ-1X2+F-12DC-PT
PT-IQ-1X2+F-24DC-PT
PT-IQ-1X2+F-48DC-PT

2801252
2801254
2801256
2801258

Pcs. /
Pkt.

1
1
1
1

Type

Order No.

PT-IQ-2X1-5DC-PT
PT-IQ-2X1-12DC-PT
PT-IQ-2X1-24DC-PT
PT-IQ-2X1-48DC-PT

2801243
2801245
2801247
2801249

Accessories
PT-IQ-1X2-5DC-P
PT-IQ-1X2-12DC-P
PT-IQ-1X2-24DC-P
PT-IQ-1X2-48DC-P
ZB 6, see page 111

Pcs. /
Pkt.

1
1
1
1

Order No.

PT-IQ-2X1+F-5DC-PT
PT-IQ-2X1+F-12DC-PT
PT-IQ-2X1+F-24DC-PT
PT-IQ-2X1+F-48DC-PT

2801244
2801246
2801248
2801250

1
1
1
1

2800774
2800775
2800776
2800777

1
1
1
1

Accessories
2800770
2800771
2800772
2800773

1
1
1
1

PT-IQ-2X1-5DC-P
PT-IQ-2X1-12DC-P
PT-IQ-2X1-24DC-P
PT-IQ-2X1-48DC-P
ZB 6, see page 111

Pcs. /
Pkt.

Type

Accessories
2800774
2800775
2800776
2800777

1
1
1
1

PT-IQ-2X1-5DC-P
PT-IQ-2X1-12DC-P
PT-IQ-2X1-24DC-P
PT-IQ-2X1-48DC-P
ZB 6, see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

75

Surge protection and interference filters
Surge protection for measurement and control technology
PLUGTRAB PT-IQ

Notes:

H

For certifications, see page 154

W

D

– Surge protection system
– Multi-level state monitoring
– Collective message about supply and remote module
– Multi-level, floating remote signaling
– System supplied via DIN rail bus
– Up to 28 protection modules per supply
module
– Maximum ease of maintenance thanks to
the two-piece design
– Plugs are coded
– Impedance-neutral disconnection of plug
for maintenance purposes
– Base element remains an integral part of
the installation
– PT-IQ...-UT base element with screw connection technology
– PT-IQ...-PT base element with push-in
connection technology

2 double conductors (loops), floating,
9/10 connection grounded directly

Total width 17.7 mm

1

2

5

6

3

4

9

10

7

8

11

12

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
DC/AC
Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core
Core-Ground
PT-IQ...UT dimensions W/H/D
Resistance per path
General data
PT-IQ...PT dimensions W/H/D
Connection data solid/stranded with ferrule/ AWG

C1 / C2 / C3 / D1
30 V DC / 21 V AC
2.5 kA
700 mA (Up to 45°C)
10 kA / 10 kA
20 kA
≤ 55 V (C3 - 25 A)
≤ 600 V (C1 - 1 kV/500 A)
17.7 mm / 91 mm / 77.5 mm
1.2 Ω
17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

Connection data, push-in solid/stranded with ferrule/AWG

0.2 ... 4 mm² / - ... - / 20 - 12

Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A1 / EN 61000-6-2 /
EN 61000-6-2/A1 / EN 61000-6-3
Via TBUS

Remote indication contact

Ordering data
Description

Voltage UN

Pcs. /
Pkt.

Type

Order No.

24 V
MCR-PLUGTRAB, consisting of a plug, base element, and DIN rail
bus, with push-in connection technology

PT-IQ-2X2-24DC-UT

2800980

1

24 V DC

PT-IQ-2X2-24DC-PT

2801263

1

2800804

1

MCR-PLUGTRAB, consisting of a plug, base element, and DIN rail
bus, with screw connection technology

Accessories

76

PHOENIX CONTACT

Replacement connector
24 V DC

PT-IQ-2X2-24DC-P

Marking material

ZB 6, see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
H

H
W

D

H
W

D

2 double conductors (loops), floating,
9/10 connection grounded via gas-filled surge
arrester

Total width 17.7 mm

W

D

4-wire with common reference potential,
9/10 connection grounded directly

4-wire with common reference potential,
9/10 connection grounded via gas-filled surge
arrester

Total width 17.7 mm

Total width 17.7 mm

1

2

1

2

1

2

5

6

5

6

5

6

7

8

7

8

3

4

9

10

11

12

11

12

7

8

9

10

9

10

11

12

3

4

3

4

Technical data

Technical data

Technical data

C1 / C2 / C3 / D1
30 V DC / 21 V AC
2.5 kA
700 mA (Up to 45°C)

C1 / C2 / C3 / D1
30 V DC / 21 V AC
2.5 kA
700 mA (Up to 45°C)

C1 / C2 / C3 / D1
30 V DC / 21 V AC
2.5 kA
700 mA (Up to 45°C)

10 kA / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

≤ 55 V (C3 - 25 A)
≤ 900 V (C1 - 1 kV/500 A)
17.7 mm / 91 mm / 77.5 mm
1.2 Ω

≤ 60 V (C3 - 50 A)
17.7 mm / 91.1 mm / 77.5 mm
1.2 Ω

≤ 780 V (C3 - 25 A)
17.7 mm / 91.1 mm / 77.5 mm
1.2 Ω

17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

0.2 ... 4 mm² / - ... - / 20 - 12

0.5 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

0.5 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12

-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A1 / EN 61000-6-2 /
EN 61000-6-2/A1 / EN 61000-6-3
Via TBUS

-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A1 / EN 61000-6-2 /
EN 61000-6-2/A1 / EN 61000-6-3
Via TBUS

-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A1 / EN 61000-6-2 /
EN 61000-6-2/A1 / EN 61000-6-3
Via TBUS

Ordering data

Ordering data

Type

Order No.

PT-IQ-2X2+F-24DC-UT

2800981

PT-IQ-2X2+F-24DC-PT

2801264

Pcs. /
Pkt.

Type

Order No.

1

PT-IQ-4X1-24DC-UT

2800982

1

PT-IQ-4X1-24DC-PT

2801271

Accessories
PT-IQ-2X2-24DC-P
ZB 6, see page 111

Ordering data
Pcs. /
Pkt.

Order No.

1

PT-IQ-4X1+F-24DC-UT

2800983

1

1

PT-IQ-4X1+F-24DC-PT

2801272

1

2800813

1

Accessories
2800804

1

PT-IQ-4X1-24DC-P
ZB 6, see page 111

Pcs. /
Pkt.

Type

Accessories
2800813

1

PT-IQ-4X1-24DC-P
ZB 6, see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

77

Surge protection and interference filters
Surge protection for measurement and control technology
PLUGTRAB PT-IQ with screw
connection

H

H

– Surge protection system
– Multi-level state monitoring
– Collective message about supply and remote module
– Multi-level, floating remote signaling
– System supplied via DIN rail bus
– Up to 28 protection modules per supply
module
– Maximum ease of maintenance thanks to
the two-piece design
– Plugs are coded
– Impedance-neutral disconnection of plug
for maintenance purposes
– Base element remains an integral part of
the installation
– Base element with screw connection
technology

W

D

5-wire with common reference potential,
9/10 connection grounded directly

For certifications, see page 154

5-wire with common reference potential,
9/10 connection grounded via gas-filled surge
arrester

Total width 17.7 mm

Notes:

Total width 17.7 mm

1

2

1

2

5

6

5

6

7

8

7

8

unprotected

Attenuation characteristics at www.phoenixcontact.net/products

W

D

protected

unprotected

protected

11

12

11

12

9

10

9

10

3

4

3

4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
DC/AC
Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core
Core-Ground
Cut-off frequency fg (3 dB)
Symmetrical in the 150 Ω system
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

Description

Voltage UN

MCR-PLUGTRAB, consisting of a plug, base element, and DIN rail
bus
Bridge between 3/4 () and 9/10
5 V DC
Bridge between 3/4 () and 9/10
24 V DC
Gas-filled surge arrester between 3/4 () and 9/10
5 V DC
Gas-filled surge arrester between 3/4 () and 9/10

Technical data

... 5DC
C1 / C2 / C3 / D1
6 V DC / 4 V AC
2.5 kA
600 mA (up to 40 °C)

... 12DC
C1 / C2 / C3 / D1
15 V DC / 10 V AC
2.5 kA
600 mA (up to 40 °C)

... 5DC
C1 / C2 / C3 / D1
6 V DC / 4 V AC
2.5 kA
600 mA (up to 40 °C)

... 12DC
C1 / C2 / C3 / D1
15 V DC / 10 V AC
2.5 kA
600 mA (up to 40 °C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

≤ 30 V (C3 - 25 A)
≤ 30 V (C3 - 25 A)

≤ 40 V (C3 - 25 A)
≤ 40 V (C3 - 25 A)

≤ 30 V (C3 - 25 A)
≤ 900 V (C3 - 25 A)

≤ 40 V (C3 - 25 A)
≤ 900 V (C3 - 25 A)

> 60 MHz

> 60 MHz

> 60 MHz

> 60 MHz

17.7 mm / 91 mm / 77.5 mm
0.2 ... 4 mm² / - ... - / 24 - 12
-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A2 / EN 61000-6-2/A1 /
EN 61000-6-3

17.7 mm / 91 mm / 77.5 mm
0.2 ... 4 mm² / - ... - / 24 - 12
-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A2 / EN 61000-6-2/A1 /
EN 61000-6-3

Ordering data

Ordering data

Type

Order No.

PT-IQ-5-HF-5DC-UT
PT-IQ-5-HF-12DC-UT

2800797
2800799

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

1
1

24 V DC

PT-IQ-5-HF+F-5DC-UT

2800798

1

PT-IQ-5-HF+F-12DC-UT

2800801

1

2800795
2800796

1
1

Accessories

Accessories

Replacement connector
PT-IQ-5-HF-5DC-P
PT-IQ-5-HF-12DC-P
Marking material

78

PHOENIX CONTACT

ZB 6, see page 111

2800795
2800796

1
1

PT-IQ-5-HF-5DC-P
PT-IQ-5-HF-12DC-P
ZB 6, see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
PLUGTRAB PT-IQ with push-in
connection technology
– Surge protection system
– Multi-level state monitoring
– Collective message about supply and remote module
– Multi-level, floating remote signaling
– System supplied via DIN rail bus
– Up to 28 protection modules per supply
module
– Maximum ease of maintenance thanks to
the two-piece design
– Plugs are coded
– Impedance-neutral disconnection of plug
for maintenance purposes
– Base element remains an integral part of
the installation
– Base element in push-in connection technology

5-wire with common reference potential,
9/10 connection grounded directly

Total width 17.7 mm

Notes:
For certifications, see page 154

5-wire with common reference potential,
9/10 connection grounded via gas-filled surge
arrester

Total width 17.7 mm

1

2

1

2

5

6

5

6

7

8

7

8

unprotected

Attenuation characteristics at www.phoenixcontact.net/products

protected

unprotected

protected

11

12

11

12

9

10

9

10

3

4

3

4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
DC/AC
Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core
Core-Ground
Cut-off frequency fg (3 dB)
Symmetrical in the 150 Ω system
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

Description

Voltage UN

MCR-PLUGTRAB, consisting of a plug, base element, and DIN rail
bus
Bridge between 3/4 () and 9/10
5 V DC
Bridge between 3/4 () and 9/10
12 V DC
Gas-filled surge arrester between 3/4 () and 9/10
5 V DC
Gas-filled surge arrester between 3/4 () and 9/10

Technical data

... 5DC
C1 / C2 / C3 / D1
6 V DC / 4 V AC
2.5 kA
600 mA (up to 40 °C)

... 12DC
C1 / C2 / C3 / D1
15 V DC / 10 V AC
2.5 kA
600 mA (up to 40 °C)

... 5DC
C1 / C2 / C3 / D1
6 V DC / 4 V AC
2.5 kA
600 mA (up to 40 °C)

... 12DC
C1 / C2 / C3 / D1
15 V DC / 10 V AC
2.5 kA
600 mA (up to 40 °C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

≤ 30 V (C3 - 25 A)
≤ 30 V (C3 - 25 A)

≤ 40 V (C3 - 25 A)
≤ 40 V (C3 - 25 A)

≤ 30 V (C3 - 25 A)
≤ 900 V (C3 - 25 A)

≤ 40 V (C3 - 25 A)
≤ 900 V (C3 - 25 A)

> 60 MHz

> 60 MHz

> 60 MHz

> 60 MHz

17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A2 / EN 61000-6-2/A1 /
EN 61000-6-3

17.7 mm / 109.3 mm / 77.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 70 °C
IP20
V0
EN 61643-21/A1 / IEC 61643-21/A2 / EN 61000-6-2/A1 /
EN 61000-6-3

Ordering data

Ordering data

Type

Order No.

PT-IQ-5-HF-5DC-PT
PT-IQ-5-HF-12DC-PT

2801291
2801293

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

1
1

12 V DC

PT-IQ-5-HF+F-5DC-PT

2801292

1

PT-IQ-5-HF+F-12DC-PT

2801295

1

2800795
2800796

1
1

Accessories

Accessories

Replacement connector
PT-IQ-5-HF-5DC-P
PT-IQ-5-HF-12DC-P
Marking material

ZB 6, see page 111

2800795
2800796

1
1

PT-IQ-5-HF-5DC-P
PT-IQ-5-HF-12DC-P
ZB 6, see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

79

Surge protection and interference filters
Surge protection for measurement and control technology
MCR-PLUGTRAB PT

Notes:

H

For certifications, see page 154

W

D

– Seamless plug-in signal circuit protection
– Maximum ease of maintenance thanks to
the two-piece design
– Base element remains an integral part of
the installation
– Impedance-neutral disconnection of connector for test and maintenance purposes
– Connectors can be checked with
CHECKMASTER

2 double wires (loops), floating

PT 2x2...
– Protection for two separate floating signal
circuits
– Installed in conjunction with the
PT 2x2...-BE base element

Total width 17.7 mm

PT 4x1...
– Protection for four wires with common
reference potential
– Installed in conjunction with the
PT 4x1...-BE base element
* Note:
Various grounding options for the base elements:
PT .x.-BE connections 9/10 (GND) directly connected to the mounting foot.
PT .x.+F-BE connection 9/10 (GND) connected to the mounting foot via a gas-filled
surge arrester.

1

2

5

6

3

4

*

IN
9

OUT
10

7

8

11

12

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC

DC/AC

Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core
Core-Ground
Cut-off frequency fg (3 dB)
Symmetrical/asymmetrical in the 50 Ω system
Resistance per path
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
450 mA (45°C)

... 12DC
... 24DC
C1 / C2 / C3 /
C1 / C2 / C3 / D1
D1
13 V DC /
28 V DC / 20 V AC
9 V AC
2.5 kA
2.5 kA
450 mA (45°C) 450 mA (45°C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

≤ 10 V
-

≤ 18 V
-

≤ 40 V
-

Typ. 1 MHz / 2.2 Ω

Typ. 3 MHz / 2.2 Ω

Typ. 6 MHz / 2.2 Ω

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

Ordering data
Description

Voltage UN

PLUGTRAB plug, with protection circuit for plugging into base element PT
5 V DC
12 V DC
24 V DC
48 V DC
12 V AC
24 V AC
48 V AC
PLUGTRAB base element, for mounting on NS 35
Bridge between 3/4 () and 9/10
Gas-filled surge arrester between 3/4 () and 9/10

Type

Order No.

Pcs. /
Pkt.

PT 2X2- 5DC-ST
PT 2X2-12DC-ST
PT 2X2-24DC-ST

2838241
2838254
2838228

10
10
10

PT 2X2-BE
PT 2X2+F-BE

2839208
2839224

10
10

2839295
2839512

10
10

Accessories

80

PHOENIX CONTACT

Shield fast connection
For Ø 3-6 mm
For Ø 5-10 mm

SSA 3-6
SSA 5-10

Labeling material

ZBF ..., see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
H

H
W

D

2 double wires (loops), floating

Total width 17.7 mm

1

2

5

6

3

OUT

Total width 17.7 mm

1

2

1

2

5

6

5

6

7

8

7

IN

8

11

12 OUT

11

12

10

7

8

11

12

9

*

3

Technical data
... 12AC
C1 / C2 / C3 / D1

4-wire, with common reference potential

4

*

9

W

D

4-wire, with common reference potential

Total width 17.7 mm

IN

H
W

D

IN

10

9

4

3

10

*

Technical data

... 24AC
C1 / C2 / C3 / D1

4

Technical data

18 V DC / 13 V AC

40 V DC / 28 V AC

2.5 kA
450 mA (45°C)

2.5 kA
450 mA (45°C)

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
300 mA (45°C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

≤ 25 V
-

≤ 55 V
-

≤ 10 V

≤ 18 V

≤ 40 V

≤ 70 V

≤ 25 V

≤ 55 V

≤ 110 V (BE: 4x1)

Typ. 4 MHz / 2.2 Ω

Typ. 8 MHz / 2.2 Ω

- / Typ. 1 MHz
4.7 Ω

- / Typ. 3 MHz
4.7 Ω

- / Typ. 6 MHz
4.7 Ω

- / Typ. 9 MHz
4.7 Ω

- / Typ. 4 MHz
4.7 Ω

- / Typ. 8 MHz
4.7 Ω

- / Typ. 10 MHz
4.7 Ω

... 12DC
C1 / C2 / C3 /
D1
13 V DC /
9 V AC
2.5 kA
300 mA (45°C)

... 24DC
C1 / C2 / C3 /
D1
28 V DC /
20 V AC
2.5 kA
300 mA (45°C)

... 48DC
C1 / C2 / C3 /
D1
53 V DC /
37 V AC
2.5 kA
300 mA (45°C)

... 12AC
C1 / C2 / C3 /
D1
18 V DC /
13 V AC
2.5 kA
300 mA (45°C)

... 24AC
C1 / C2 / C3 /
D1
40 V DC /
13 V AC
2.5 kA
300 mA (45°C)

... 48AC
C1 / C2 / C3 / D1

2.5 kA
300 mA (45°C)

77 V DC / 55 V AC

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs. /
Pkt.

PT 2X2-12AC-ST
PT 2X2-24AC-ST

2838270
2838283

10
10

PT 2X2-BE
PT 2X2+F-BE

2839208
2839224

10
10

Type

Order No.

Pcs. /
Pkt.

PT 4X1- 5DC-ST
PT 4X1-12DC-ST
PT 4X1-24DC-ST
PT 4X1-48DC-ST

2838306
2838319
2838322
2858014

10
10
10
10

PT 4X1-BE
PT 4X1+F-BE

Accessories
SSA 3-6
SSA 5-10
ZBF ..., see page 111

2839363
2839376

10
10

Type

Order No.

Pcs. /
Pkt.

PT 4X1-12AC-ST
PT 4X1-24AC-ST
PT 4X1-48AC-ST

2838348
2838351
2804856

10
10
10

PT 4X1-BE
PT 4X1+F-BE

2839363
2839376

10
10

2839295
2839512

10
10

Accessories
2839295
2839512

10
10

SSA 3-6
SSA 5-10
ZBF ..., see page 111

OUT

Accessories
2839295
2839512

10
10

SSA 3-6
SSA 5-10
ZBF ..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

81

Surge protection and interference filters
Surge protection for measurement and control technology
MCR-PLUGTRAB PT

Notes:

H

For certifications, see page 154

W

D

– Seamless plug-in signal circuit protection
– Maximum ease of maintenance thanks to
the two-piece design
– Base element remains an integral part of
the installation
– Impedance-neutral disconnection of connector for test and maintenance purposes
– Connectors can be checked with
CHECKMASTER

Double wire (loop), floating

PT 1x2...
– Protection for a floating signal circuit
– Installed in conjunction with the
PT 1x2...-BE base element

Total width 17.7 mm

PT 2x1...
– Protection for two wires with common
reference potential
– Installed in conjunction with the
PT 2x1...-BE base element
* Note:
Various grounding options for the base elements:
PT .x.-BE connections 9/10 (GND) directly connected to the mounting foot.
PT .x.+F-BE connection 9/10 (GND) connected to the mounting foot via a gas-filled
surge arrester.

7

8

11

12

OUT

IN
9

10

*

3

4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC

DC/AC

Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core
Core-Ground
Cut-off frequency fg (3 dB)
Symmetrical/asymmetrical in the 50 Ω system
Resistance per path
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
450 mA (45°C)

... 12DC
... 24DC
... 48DC
C1 / C2 / C3 /
C1 / C2 / C3 /
C1 / C2 / C3 /
D1
D1
D1
13 V DC /
28 V DC /
53 V DC /
9 V AC
20 V AC
37 V AC
2.5 kA
2.5 kA
2.5 kA
450 mA (45°C) 450 mA (45°C) 450 mA (45°C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

≤ 10 V
-

≤ 18 V
-

≤ 40 V
-

≤ 70 V
-

Typ. 1 MHz / 2.2 Ω

Typ. 3 MHz / 2.2 Ω

Typ. 6 MHz / 2.2 Ω

Typ. 10 MHz / 2.2 Ω

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

Ordering data
Description

Voltage UN

PLUGTRAB plug, with protection circuit for plugging into base element PT
5 V DC
12 V DC
24 V DC
12 V AC
24 V AC
48 V DC
PLUGTRAB base element, for mounting on NS 35
Bridge between 3/4 () and 9/10
Gas-filled surge arrester between 3/4 () and 9/10

Type

Order No.

Pcs. /
Pkt.

PT 1X2- 5DC-ST
PT 1X2-12DC-ST
PT 1X2-24DC-ST

2856016
2856029
2856032

10
10
10

PT 1X2-48DC-ST

2803658

10

PT 1X2-BE
PT 1X2+F-BE

2856113
2856126

10
10

2839295
2839512

10
10

Accessories

82

PHOENIX CONTACT

Shield fast connection
For Ø 3-6 mm
For Ø 5-10 mm

SSA 3-6
SSA 5-10

Labeling material

ZBF ..., see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
H

H
W

D

Double wire (loop), floating

Total width 17.7 mm

7

8

11

12

OUT

IN

Total width 17.7 mm

7

8

7

8

11

12

11

12

OUT

IN
9

*

4
3

Technical data
... 12AC
C1 / C2 / C3 / D1

2-wire, with common reference potential

OUT

IN

10

*

3

W

D

2-wire, with common reference potential

Total width 17.7 mm

9

H
W

D

10

9

4

3

Technical data

... 24AC
C1 / C2 / C3 / D1

10

*

4

Technical data

18 V DC / 13 V AC

40 V DC / 28 V AC

2.5 kA
450 mA (45°C)

2.5 kA
450 mA (45°C)

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
300 mA (45°C)

... 12DC
C1 / C2 / C3 /
D1
13 V DC /
9 V AC
2.5 kA
300 mA (45°C)

... 24DC
C1 / C2 / C3 / D1

... 12AC
C1 / C2 / C3 / D1

... 24AC
C1 / C2 / C3 / D1

28 V DC / 20 V AC

18 V DC / 13 V AC

40 V DC / 28 V AC

2.5 kA
300 mA (45°C)

2.5 kA
300 mA (45°C)

2.5 kA
300 mA (45°C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

- / 10 kA
20 kA

≤ 25 V
-

≤ 55 V
-

≤ 10 V

≤ 18 V

≤ 40 V

≤ 25 V

≤ 55 V

Typ. 4 MHz / 2.2 Ω

Typ. 8 MHz / 2.2 Ω

- / Typ. 1 MHz
4.7 Ω

- / Typ. 3 MHz
4.7 Ω

- / Typ. 6 MHz
4.7 Ω

- / Typ. 4 MHz
4.7 Ω

- / Typ. 8 MHz
4.7 Ω

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs. /
Pkt.

PT 1X2-12AC-ST
PT 1X2-24AC-ST

2856045
2856058

10
10

PT 1X2-BE
PT 1X2+F-BE

2856113
2856126

10
10

Type

Order No.

Pcs. /
Pkt.

PT 2X1- 5DC-ST
PT 2X1-12DC-ST
PT 2X1-24DC-ST

2856061
2856074
2856087

10
10
10

PT 2X1-BE
PT 2X1+F-BE

Accessories
SSA 3-6
SSA 5-10
ZBF ..., see page 111

2856139
2856142

10
10

Type

Order No.

Pcs. /
Pkt.

PT 2X1-12AC-ST
PT 2X1-24AC-ST

2856090
2856100

10
10

PT 2X1-BE
PT 2X1+F-BE

2856139
2856142

10
10

2839295
2839512

10
10

Accessories
2839295
2839512

10
10

SSA 3-6
SSA 5-10
ZBF ..., see page 111

Accessories
2839295
2839512

10
10

SSA 3-6
SSA 5-10
ZBF ..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

83

Surge protection and interference filters
Surge protection for measurement and control technology
MCR-PLUGTRAB PT
H

H

– Seamless plug-in signal circuit protection
– Maximum ease of maintenance thanks to
the two-piece design
– Base element remains an integral part of
the installation
– Impedance-neutral disconnection of connector for test and maintenance purposes
– Connectors can be checked with
CHECKMASTER

W

D

4-wire, floating, impedance-free

* Note:
Various grounding options for the base elements:
PT .x.-BE connections 9/10 (GND) directly connected to the mounting foot.
PT .x.+F-BE connection 9/10 (GND) connected to the mounting foot via a gas-filled
surge arrester.

Combination of double wire protection
(floating) and single-phase power supply

Total width 17.7 mm

Total width 17.7 mm
11(+)

1

2

5

6

7

8

OUT

IN

Notes:

W

D

OUT

IN
7(-)

For certifications, see page 154
12

11

*

9
3

Maximum continuous operating voltage UC
Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core
Core-Ground

5

6

4

1

2

3

4

Technical data

... 5DC
C1 / C2 / C3 /
D1
6 V DC /
4 V AC
2.5 kA
2 A (80 °C)

... 12DC
C1 / C2 / C3 /
D1
12.8 V DC /
9 V AC
2.5 kA
2 A (80 °C)

... 24DC
C1 / C2 / C3 /
D1
27 V DC /
19 V AC
2.5 kA
2 A (80 °C)

... 24AC
C1 / C2 / C3 /
D1
40 V DC /
28 V AC
2.5 kA
2 A AC (80 °C)

44 V DC / 34 V AC

40 V DC / 28 V AC

6 A (30 °C)

2.5 kA
450 mA (45°C)

720 A / 10 kA
20 kA
10 kA

690 A / 10 kA
20 kA
10 kA

365 A / 10 kA
20 kA
10 kA

187 A / 10 kA
20 kA
10 kA

700 A / 700 A
2 kA

10 kA / 10 kA
20 kA
10 kA

≤ 10 V
≤ 450 V

≤ 18 V
≤ 450 V

≤ 40 V
≤ 450 V
(PT 4-BE)

≤ 75 V
≤ 450 V
(PT 4-BE)

-

≤ 55 V
450 V

General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21 / DIN EN 61643-21 / UL 497B

Mains protection
III / T3

PLUGTRAB plug, with protection circuit for plugging into base element PT
5 V DC
12 V DC
24 V DC
24 V AC
PLUGTRAB base element, for mounting on NS 35
Bridge between 3/4 () and 9/10
Gas-filled surge arrester between 3/4 () and 9/10

Data protection
C1 / C2 / C3 / D1

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-1 / EN 61643-11
IEC 61643-21

Ordering data
Voltage UN

8(-)

10

Technical data
Electrical data
IEC category / EN type

Description

12(+)

Ordering data

Type

Order No.

Pcs. /
Pkt.

PT 4- 5DC-ST
PT 4-12DC-ST
PT 4-24DC-ST
PT 4-24AC-ST

2839211
2839237
2839240
2800078

10
10
10
1

PT 4-BE
PT 4+F-BE

2839402
2839415

10
10

Type

Order No.

Pcs. /
Pkt.

PT PE/S+1X2-24-ST

2819008

10

2856265

10

2839295
2839512

10
10

PLUGTRAB base element, for mounting on NS 35
PT PE/S+1X2-BE

Accessories
Shield fast connection
For Ø 3-6 mm
For Ø 5-10 mm

SSA 3-6
SSA 5-10

Labeling material

ZBF ..., see page 111

84

PHOENIX CONTACT

Accessories
2839295
2839512

10
10

SSA 3-6
SSA 5-10
ZBF ..., see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
MCR-PLUGTRAB PT
H

H

– Protective devices for use in telecommunications and signaling networks according to IEC 61643-21
– Seamless plug-in signal circuit protection
– Maximum ease of maintenance thanks to
the two-piece design
– Base element remains an integral part of
the installation
– Impedance-neutral disconnection of connector for test and maintenance purposes
– Connectors can be checked with
CHECKMASTER

W

D

W

D

2-wire, floating, free of leakage current

2-wire, with common reference potential,
remote signaling

Notes:
Total width 17.7 mm

For certifications, see page 154

Total width 17.7 mm
1(+)

1

2(+)

2
J

3(-)

3

4

OUT
J

11
5(+)

12
5

4(-)

IN

6(+)
J

6

12

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Lightning test curr. Iimp (10/350) µs
Nominal current IN
Nominal discharge surge current In (8/20) µs

DC/AC
Per path

Core-Ground

Technical data

... 120AC
C1 / C2 / C3
- / 175 V AC

... 230AC
C1 / C2 / C3 / D1
- / 250 V AC

300 A
6A

500 A
6A

... 60AC
C2
100 V DC /
75 V AC
26 A (30 °C)

... 120AC
C2
200 V DC /
150 V AC
26 A (30 °C)

... 230AC
C2
350 V DC / 275 V AC
26 A (30 °C)

3 kA

3 kA

Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs

8 kA

8 kA

2 kA (C2 4 kV/2 kA)
4 kA

2.5 kA (C2 5 kV/2.5 kA)
5 kA

5 kA

Core-Ground
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

≤ 800 V

≤ 1.4 kV

≤ 200 V

≤ 380 V

≤ 650 V

Description

Voltage UN

2.5 kA (C2 - 5 kV/2.5 kA)

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 80 °C
IP20
V0
EN 61643-21

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 616431 / DIN EN 61643-21

Ordering data

Ordering data
Order No.

Pcs. /
Pkt.

PT 2X1-VF-120AC
PT 2X1-VF-230AC

2859327
2805460

10
10

PT 2X1-VF-120AC-ST
PT 2X1-VF-230AC-ST

2856799
2921365

2839282

Type

11

Type

Order No.

Pcs. /
Pkt.

10
10

PT 2X1VA- 60AC-ST
PT 2X1VA-120AC-ST
PT 2X1VA-230AC-ST

2839172
2839185
2839198

10
10
10

10

PT-BE/FM

2839282

10

2839295
2839512

10
10

MAINS-PLUGTRAB, consisting of a connector and a base element
120 V AC
230 V AC
PLUGTRAB plug, with protection circuit for plugging into base element PT
60 V AC
120 V AC
230 V AC
PLUGTRAB base element, for mounting on NS 35

PT-BE/FM

Accessories
Shield fast connection
For Ø 3-6 mm
For Ø 5-10 mm

SSA 3-6
SSA 5-10

Labeling material

ZBF ..., see page 111

Accessories
2839295
2839512

10
10

SSA 3-6
SSA 5-10
ZBF ..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

85

Surge protection and interference filters
Surge protection for measurement and control technology
MCR-PLUGTRAB PT
Coarse surge protection

H

H

– For systems with high dielectric strength
or fine protection installed
– Installation location - directly where the
MCR cable enters the building
– Seamless plug-in signal circuit protection
– Maximum ease of maintenance thanks to
the two-piece design
– Base element remains an integral part of
the installation
– Impedance-neutral disconnection of connector for test and maintenance purposes
– Connectors can be checked with
CHECKMASTER

W

D

2-wire, coarse protection

4-wire, coarse protection

Total width 17.7 mm

Notes:

W

D

Total width 17.7 mm

For certifications, see page 154
1

2

5

6

1

2

5

6

7

8

OUT

IN
OUT

IN

3

11

12

9

10

3

4

4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
DC/AC
Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Ground
Output voltage limitation at 1 kV/µs
Core-Ground
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

Technical data

C1 / C2 / C3 / D1
68 V DC / 48 V AC
5 kA
2 A (80 °C)

C1 / C2 / C3 / D1
170 V DC / 120 V AC
2.5 kA
2 A (80 °C)

- / 20 kA
40 kA

10 kA / 10 kA
20 kA

≤ 600 V

≤ 450 V

≤ 600 V

≤ 450 V

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

Ordering data
Description

Voltage UN

PLUGTRAB plug, with protection circuit for plugging into base element PT
48 V AC
110 V AC
PLUGTRAB base element, for mounting on NS 35

Ordering data

Type

Order No.

Pcs. /
Pkt.

PT 2-F-ST

2859000

10

PT-BE/FM

2839282

Type

Order No.

Pcs. /
Pkt.

PT 4-F-ST

2858441

10

2839402

10

2839295
2839512

10
10

10

Bridge between 3/4 () and 9/10

PT 4-BE

Accessories
Shield fast connection
For Ø 3-6 mm
For Ø 5-10 mm

SSA 3-6
SSA 5-10

Labeling material

ZBF ..., see page 111

86

PHOENIX CONTACT

Accessories
2839295
2839512

10
10

SSA 3-6
SSA 5-10
ZBF ..., see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
MCR-PLUGTRAB PT
For Ex-i circuits

H

H

– Tailored to the special requirements of intrinsically safe circuits
– Seamless plug-in signal circuit protection
– Maximum ease of maintenance thanks to
the two-piece design
– Base element remains an integral part of
the installation
– Impedance-neutral disconnection of connector for test and maintenance purposes
– Connectors can be checked with
CHECKMASTER

W

D

W

D

2 double wires (loops), intrinsically safe

4-wire, intrinsically safe, impedance-free

Notes:
For certifications, see page 154
Total width 17.7 mm

IN

Total width 17.7 mm

1

2

5
3
9
7

6
4
10
8

11

12

OUT

1

2

5
3

6
4

9

10

7

8

11

12

OUT

IN

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
DC/AC
Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core
Core-Ground
Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
Symmetrical in the 50 Ω system
Resistance per path
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards
Safety data
EC-type examination certificate according to ATEX
Identification according to ATEX

Technical data

C1 / C2 / C3 / D1
30 V DC / 21 V AC
1 kA
325 mA (40°C)

C1 / C2 / C3 / D1
30 V DC / 21 V AC
1 kA
500 mA (40°C)

10 kA / 10 kA
20 kA

308 A / 10 kA
20 kA

≤ 50 V (C3 - 25 A)
≤ 1 kV (C2 - 10 kV / 5 kA)

≤ 50 V (C3 - 25 A)
≤ 1 kV (C2 - 10 kV / 5 kA)

≤ 45 V / ≤ 1 kV

≤ 45 V / ≤ 1 kV

Typ. 4.5 MHz
2.2 Ω

Typ. 7 MHz
-

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
EN 61643-21 / EN 60079-0 / EN 60079-11 /
EN 60079-26 / EN 61241-0 / EN 61241-11

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
EN 61643-21 / EN 60079-0 / EN 60079-11 /
EN 60079-26 / EN 61241-0 / EN 61241-11

KEMA 00ATEX1099 X

KEMA 00ATEX1099 X
 II 1G Ex ia IIC T4...T6 Ga
 II 1D Ex ia IIIC T135°C...T85°C Da
1.1 nF
1 µH
500 mA (T4 / ≤ 80°C)
30 V DC
850 mW (T4 / ≤ 80°C)

 II 1G Ex ia IIC T4...T6 Ga
 II 1D Ex ia IIIC T135°C...T85°C Da

Maximum inner capacity Ci
Maximum inner inductance Li
Maximum input current Ii
Maximum input voltage Ui
Maximum input power Pi

1.3 nF
1 µH
325 mA (T4 / ≤ 80°C)
30 V DC
3W

Ordering data
Description

Voltage UN

PLUGTRAB plug, with protection circuit for plugging into base element PT
24 V DC
PLUGTRAB base element, for mounting on NS 35

Type

PT 2XEX(I)-24DC-ST

PT 2XEX(I)-BE

Ordering data
Order No.

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

2838225

10

PT 4-EX(I)-24DC-ST

2839253

10

2839279

10

PT 4-EX(I)-BE

2839486

10

2839295
2839512

10
10

Accessories
Shield fast connection
For Ø 3-6 mm
For Ø 5-10 mm

SSA 3-6
SSA 5-10

Labeling material

ZBF ..., see page 111

Accessories
2839295
2839512

10
10

SSA 3-6
SSA 5-10
ZBF ..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

87

Surge protection and interference filters
Surge protection for measurement and control technology
MCR-PLUGTRAB PT

Notes:

H

For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

– Protection for fieldbus systems,
PROFIBUS, and signal circuits with 3 to
5-wire technology
– Cable shield connection using SSA...
shield fast connection
– Grounding plug (PT MCR-EST) to short
circuit and ground the potentials in
PLUGTRAB-PT base elements
– Seamless plug-in signal circuit protection
– Maximum ease of maintenance thanks to
the two-piece design
– Base element remains an integral part of
the installation
– Impedance-neutral disconnection of connector for test and maintenance purposes
– Connectors can be checked with
CHECKMASTER
* Note:
Various grounding options for the base elements:
PT .x.-BE connections 9/10 (GND) directly connected to the mounting foot.
PT .x.+F-BE connection 9/10 (GND) connected to the mounting foot via a gas-filled
surge arrester.

W

D

5-wire, with common reference potential

Total width 17.7 mm
1

2

5

6

7

8

11

12

OUT

IN

*

9
3

10
4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC

... 5DC
C1 / C2 / C3 / D1
DC/AC

Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core
Core-Ground
Cut-off frequency fg (3 dB)
Symmetrical in the 100 Ω system
Resistance per path
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

... 12DC
C1 / C2 / C3 / D1

5.2 V DC / 3.6 V AC

14 V DC / 9.8 V AC

2.5 kA
450 mA (45°C)

2.5 kA
450 mA (45°C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

≤ 15 V
≤ 15 V

≤ 25 V
≤ 25 V

Typ. 70 MHz
2.2 Ω

Typ. 70 MHz
2.2 Ω
17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21/A1 / EN 61643-21/A1

Ordering data
Description

Voltage UN

PLUGTRAB plug, with protection circuit for plugging into base element PT
5 V DC
Protection for 2 signal conductors
12 V DC
24 V DC
Grounding plug, for MCR-PLUGTRAB base elements

Type

Order No.

Pcs. /
Pkt.

PT 5-HF- 5 DC-ST
PT 5-HF-12 DC-ST

2838762
2838775

10
10

PT 2X2-BE
PT 2X2+F-BE

2839208
2839224

10
10

2839295
2839512

10
10

PLUGTRAB base element, for mounting on NS 35
Bridge between 3/4 () and 9/10
Gas-filled surge arrester between 3/4 () and 9/10

Accessories

88

PHOENIX CONTACT

Shield fast connection
For Ø 3-6 mm
For Ø 5-10 mm

SSA 3-6
SSA 5-10

Labeling material

ZBF ..., see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
H

H
W

D

W

D

2 x 2 conductor, floating

3-wire, PROFIBUS (up to 12 MHz)

Total width 17.7 mm

Grounding plug for MCR-PLUGTRAB

Total width 17.7 mm

1

2

5

6

7

8

11

OUT

IN
11
9

*

3

Total width 17.7 mm

7

8

11

12

OUT

IN

12

9

10

3

10

*

7

8

5

6

1

2

OUT

IN

4

9

4

(

Technical data
... 3-PB
C1 / C2 / C3 / D1

... 12DC
C1 / C2 / C3 /
D1
13 V DC /
9 V AC
2.5 kA
450 mA (45°C)

28 V DC / 19.8 V AC

5.2 V DC / 3.6 V AC

14 V DC / 9.8 V AC

-

2.5 kA
450 mA (45°C)

2.5 kA
450 mA (45°C)

2.5 kA
450 mA (45°C)

2 A (at 40 °C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

-

≤ 15 V
-

≤ 25 V
-

≤ 45 V
-

≤ 15 V
≤ 15 V

≤ 25 V
≤ 25 V

-

Typ. 70 MHz
2.2 Ω

Typ. 70 MHz
2.2 Ω

Typ. 70 MHz
2.2 Ω

Typ. 70 MHz
2.2 Ω

Typ. 70 MHz
2.2 Ω

-

... 3-HF
C1 / C2 / C3 / D1

17.7 mm / 45 mm / 52 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

17.7 mm / 90 mm / 65.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V0
IEC 61643-21/A1 / EN 61643-21/A1

Ordering data

Ordering data
Order No.

Pcs. /
Pkt.

PT 2X2-HF- 5 DC-ST
PT 2X2-HF-12 DC-ST
PT 2X2-HF-24 DC-ST

2839567
2839570
2839729

10
10
10

PT 2X2-BE
PT 2X2+F-BE

2839208
2839224

10
10

SSA 3-6
SSA 5-10
ZBF ..., see page 111

17.7 mm / 90 mm / 65.5 mm
-40 °C ... 85 °C
IP20
V0
-

Ordering data
Order No.

Pcs. /
Pkt.

PT 3-PB-ST
PT 3-HF-12DC-ST

2858030
2858043

10
10

Accessories

2856113
2856126

Type

Order No.

Pcs. /
Pkt.

PT MCR-EST

2880749

10

10
10

Accessories
2839295
2839512

10
10

SSA 3-6
SSA 5-10
ZBF ..., see page 111

)

-

Type

PT 1X2-BE
PT 1X2+F-BE

4(

Technical data

... 5DC
C1 / C2 / C3 /
D1
5.2 V DC /
3.6 V AC
2.5 kA
450 mA (45°C)

Type

10

*

)3

Technical data

... 24DC
C1 / C2 / C3 / D1

12

Accessories
2839295
2839512

10
10
ZBF ..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

89

Surge protection and interference filters
Surge protection for measurement and control technology
LINETRAB LIT

Notes:

H

For certifications, see page 154

D

For additional safety data, visit www.phoenixcontact.com

– Protection of up to four signal wires with
a design width of 6.2 mm
– Can be used in binary, analog, and intrinsically safe circuits

W

The latest information on approvals and
use in intrinsically safe circuits can be found
at www.phoenixcontact.net/products.
Double wire (loop), floating

Total width 6.2 mm

IN
7

OUT
8

5

6

3

4

1

2

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
DC/AC
Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core / Core-Ground

C1 / C2 / C3 / D1
36 V DC / 25 V AC
500 A
350 mA (40°C)
5 kA / 5 kA
20 kA
≤ 50 V (C3 - 10 A) / ≤ 650 V (C1 - 500 V / 250 A)

Cut-off frequency fg (3 dB)
Symmetrical in the 50 Ω system
Resistance per path
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards
Safety data
EC-type examination certificate according to ATEX
Identification according to ATEX

Typ. 6 MHz
3.3 Ω
6.2 mm / 93 mm / 102.5 mm
0.14 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
-40 °C ... 80 °C
IP20
V0
IEC 61643-21 / DIN EN 61643-21 / EN 60079-0 /
EN 60079-11 / EN 60079-26 / EN 61241-0
KEMA 09ATEX0051 X

 II 1 G Ex ia IIC T4...T6
 II 1 D Ex iaD 20 T85°C...135°C

Maximum inner capacity Ci
Maximum inner inductance Li
Maximum input current Ii
Maximum input voltage Ui
Maximum input power Pi

1.3 nF
< 1 µH
350 mA (T4 / ≤ 80°C)
36 V DC
3W

Ordering data
Description

Voltage UN

Type

Order No.

Pcs. /
Pkt.

2804610

10

LINETRAB
24 V DC

LIT 1X2-24

Accessories
System adapter, for MINI Analog modules with screw connection

90

PHOENIX CONTACT

MINI MCR-SL-V8-FLK 16-A

2811268

1

VARIOFACE system cable for connecting LIT and MINI Analog
via system adapter
Cable length: 2 m
Cable length: 1 m
Cable length: 0.5 m

VIP-CAB-FLK16/FR/FR/0,14/2,0M
VIP-CAB-FLK16/FR/FR/0,14/1,0M
VIP-CAB-FLK16/FR/FR/0,14/0,5M

2900156
2900155
2900154

1
1
1

UniCard sheets, for marker groove

UC-TM 6 (see page 111)

Surge protection and interference filters
Surge protection for measurement and control technology
H

H
W

D

2 double wires (loops), floating

H
W

D

2-wire, with common reference potential

Total width 6.2 mm

4-wire, with common reference potential

Total width 6.2 mm

Total width 6.2 mm

IN
7

OUT
8

IN
7

8

5

6

5

6

3

4

3

4

1

2

2

1

OUT

Technical data

W

D

IN
7

OUT
8

5
3

6
4

1

2

Technical data

Technical data

C1 / C2 / C3 / D1
36 V DC / 25 V AC
500 A
350 mA (40°C)

C1 / C2 / C3 / D1
36 V DC / 25 V AC
500 A
350 mA (40°C)

C1 / C2 / C3 / D1
36 V DC / 25 V AC
500 A
350 mA (40°C)

5 kA / 5 kA
20 kA

- / 5 kA
20 kA

- / 5 kA
20 kA

≤ 50 V (C3 - 10 A) / ≤ 650 V (C1 - 500 V / 250 A)

- / ≤ 60 V (C1 - 500 V / 250 A)

- / ≤ 60 V (C1 - 500 V / 250 A)

Typ. 6 MHz
3.3 Ω

3.3 Ω

3.3 Ω

6.2 mm / 93 mm / 102.5 mm
0.14 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
-40 °C ... 80 °C
IP20
V0
IEC 61643-21 / DIN EN 61643-21 / EN 60079-0 /
EN 60079-11 / EN 60079-26 / EN 61241-0

6.2 mm / 93 mm / 102.5 mm
0.14 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
-40 °C ... 80 °C
IP20
V0
IEC 61643-21 / DIN EN 61643-21
-

6.2 mm / 93 mm / 102.5 mm
0.14 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
-40 °C ... 80 °C
IP20
V0
IEC 61643-21 / DIN EN 61643-21
-

KEMA 09ATEX0051 X
 II 1 G Ex ia IIC T4...T6
 II 1 D Ex iaD 20 T85°C...135°C
1.3 nF
< 1 µH
350 mA (T4 / ≤ 80°C)
36 V DC
3W

-

-

-

-

Ordering data
Type

LIT 2X2-24

Accessories

UC-TM 6 (see page 111)

Ordering data
Order No.

Pcs. /
Pkt.

2804623

10

Type

LIT 2X1-24

Ordering data
Order No.

Pcs. /
Pkt.

2804636

10

Type

LIT 4X1-24

Accessories

UC-TM 6 (see page 111)

Order No.

Pcs. /
Pkt.

2804649

10

Accessories

UC-TM 6 (see page 111)

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

91

Surge protection and interference filters
Surge protection for measurement and control technology
LINETRAB LIT
H

H

– Protection for up to four signal wires
– Cross-arrester bridging of the reference
potential with ME 6,2 TBUS
– Protection of up to four signal wires with
a design width of 6.2 mm
– Complete normal mode voltage protection between all wires

D

W

D

W

Notes:
For certifications, see page 154

2-wire, floating, impedance-free

4-wire, floating, impedance-free

For additional safety data, visit www.phoenixcontact.com

Total width 6.2 mm

Total width 6.2 mm

IN

OUT

7

8

5

6

3

4

1

2

IN

OUT

7

8

5
3

6
4

1

2

X

X

Technical data

Technical data

Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
DC/AC
Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core
Core-Ground
Cut-off frequency fg (3 dB)
Asymmetrical in the 50 Ω system
Resistance per path
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards
Safety data
EC-type examination certificate according to ATEX
Identification according to ATEX

... 12
C1 / C2 / C3 / D1
18 V DC / 13 V AC
500 A
500 mA (40°C)

... 24
C1 / C2 / C3 / D1
36 V DC / 25 V AC
500 A
500 mA (40°C)

... 12
C1 / C2 / C3 / D1
18 V DC / 13 V AC
500 A
500 mA (40°C)

... 24
C1 / C2 / C3 / D1
36 V DC / 25 V AC
500 A
500 mA (40°C)

350 A / 5 kA
20 kA

250 A / 5 kA
20 kA

350 A / 5 kA
20 kA

250 A / 5 kA
20 kA

≤ 50 V (C3 - 10 A)
≤ 650 V (C2 - 10 kV / 5 kA)

≤ 60 V (C3 - 10 A)
≤ 650 V (C2 - 10 kV / 5 kA)

≤ 50 V (C3 - 10 A)
≤ 650 V (C2 - 10 kV / 5 kA)

≤ 60 V (C3 - 10 A)
≤ 650 V (C2 - 10 kV / 5 kA)

Typ. 5 MHz
0Ω

Typ. 7.5 MHz
0Ω

Typ. 5 MHz
0Ω

Typ. 7.5 MHz
0Ω

Maximum inner capacity Ci
Maximum inner inductance Li
Maximum input current Ii
Maximum input voltage Ui
Maximum input power Pi

3 nF
< 1 µH
500 mA (T4 / -40...+80°C)
18 V DC
635 mW

6.2 mm / 93 mm / 102.5 mm
0.14 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
-40 °C ... 80 °C
IP20
V0
IEC 61643-21 / DIN EN 61643-21 / EN 60079-0 /
KEMA 09ATEX0051 X

6.2 mm / 93 mm / 102.5 mm
0.14 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
-40 °C ... 80 °C
IP20
V0
IEC 61643-21 / DIN EN 61643-21 / EN 60079-0 /

KEMA 09ATEX0051 X

 II 1 G Ex ia IIC T4...T6
 II 1 G Ex ia IIC T4...T6
 II 1 D Ex iaD 20 T85°C...135°C  II 1 D Ex iaD 20 T85°C...135°C
1.3 nF
< 1 µH
500 mA (T4 / -40...+80°C)
36 V DC
635 mW

KEMA 09ATEX0051 X
 II 1 G Ex ia IIC T4...T6
 II 1 D Ex iaD 20 T85°C...135°C
6 nF
< 1 µH
500 mA (T4 / -40...+80°C)
18 V DC
550 mW

Ordering data
Description

Voltage UN

LINETRAB, with integrated surge protection, for mounting on
NS 35
12 V DC
24 V DC

KEMA 09ATEX0051 X
 II 1 G Ex ia IIC T4...T6
 II 1 D Ex iaD 20 T85°C...135°C
2.5 nF
< 1 µH
500 mA (T4 / -40...+80°C)
36 V DC
550 mW

Ordering data

Type

Order No.

Pcs. /
Pkt.

LIT 2-12
LIT 2-24

2804694
2804665

10
10

Accessories

Type

Order No.

Pcs. /
Pkt.

LIT 4-12
LIT 4-24

2804704
2804678

10
10

2969401

10

Accessories

System adapter, for MINI Analog modules with screw connection
MINI MCR-SL-V8-FLK 16-A

2811268

1

ME 6,2 TBUS-2 1,5/5-ST-3,81KMGY

2969401

10

DIN rail connector
UniCard sheets, for marker groove

92

PHOENIX CONTACT

UC-TM 6 (see page 111)

ME 6,2 TBUS-2 1,5/5-ST-3,81KMGY
UC-TM 6 (see page 111)

Surge protection and interference filters
Surge protection for measurement and control technology
Assembled round cable
VIP-CAB-FLK16/FR...

Assembled round cable
VIP-CAB-FLK16/FR...

Front adapter
e.g., FLKM 16-PA-S300/MINI-MCR
(see catalog 7)

System adapter
MINI MCR-SL-V8-FLK 16-A

Configuration aid for LINETRAB - MINI Analog
Since LINETRAB and MINI Analog housing is the same shape, the advantages of system cabling can be utilized. You can create
a perfectly coordinated, protected signal string from the sensor through to the controller.
The table below lists possible combinations with the system adapter (8 modules each). The complete configuration aid is
available in the Download Center under LINETRAB. More detailed information about MINI Analog can be found in the catalog 7.

TRABTECH - LINETRAB
Order No.

2804610

Type

LIT 1X2-24

INTERFACE - MINI Analog
Order No.

Type

2864383

MINI MCR-SL-UI-UI

2864150

MINI MCR-SL-UI-UI-NC

2865007

MINI MCR-SL-U-UI-NC

2813512

MINI MCR-SL-U-I-0

2813525

MINI MCR-SL-U-I-4

2813541

MINI MCR-SL-I-U-0

2813538

MINI MCR-SL-I-U-4

2864406

MINI MCR-SL-I-I

2864684

MINI MCR-SL-U-U

2864794

MINI MCR-SL-UI-2I

2864176

MINI MCR-SL-UI-2I-NC

2864419

MINI MCR-SL-1CP-I-I

2864082

MINI MCR-SL-UI-F

2864105

MINI MCR-SL-NAM-2RNO

2864480

MINI MCR-SL-UI-REL

2810780

MINI MCR-SL-SHUNT-UI-NC

2810858

MINI MCR-SL-SHUNT-UI

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

93

Surge protection and interference filters
Surge protection for measurement and control technology
Modular terminal blocks with
multiple stage surge protection
TERMITRAB
– Multi-stage modular terminal blocks with
screw connection method
– Versions with and without disconnect
knife
– Disconnection of signal circuits by disconnect knife

Notes:

H

For certifications, see page 154

W

D

TT-2-PE-
– Protection of a floating double wire
– E.g., 0 - 20 mA or 0 - 10 V signals

Double wire (loop), floating

TT-2-PE/S1
– Protection of a floating double wire in
which the introduction of additional resistors for decoupling the protection stages
leads to problems
– E.g., for two-wire temperature measurement, PT 100

Total width 6.2 mm

1

3

OUT

IN

TT-2/2
– Protection of two signal wires with common reference potential
– E.g., binary signals of position encoders
TT-EX(I)-
– Protection of a floating double wire in intrinsically safe circuits
– Use in Ex protection zones 1 and 2
– Wires can be led through to Ex protection zone 0
– To terminate a row of TERMITRAB TT...
devices, covers are available in the corresponding colors
– Other voltage levels available on request

2

4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC

DC/AC

Lightning test curr. Iimp (10/350) µs
Per path
Nominal load current IL
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
Symmetrical/asymmetrical in the 50 Ω system
Resistance per path
General data
Dimensions W/H/D (with disconnect knife)
Dimensions W/H/D (without disconnect knife)
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards
Safety data
EC-type examination certificate according to ATEX
Identification according to ATEX

... M-24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
500 A
300 mA (40°C)

... 24DC
C1 / C2 / C3 /
D1
30 V DC / -

... 110AC
C1 / C2 / C3 / D1

500 A
500 A
300 mA (40°C) 300 mA (30 °C)

5 kA / 5 kA
10 kA

5 kA / 5 kA
10 kA

5 kA / 5 kA
10 kA

≤ 45 V /
≤ 650 V

≤ 45 V /
≤ 650 V

≤ 250 V / ≤ 650 V

Typ. 6 MHz / 3.3 Ω

Typ. 3.2 MHz / - Typ. 15 MHz / 3.7 Ω
9.4 Ω

- / 120 V AC

6.2 mm / 92 mm / 66.45 mm
6.2 mm / 79.6 mm / 54.6 mm
0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
-40 °C ... 80 °C
IP20
V2
-

-

-

Approvals according to IECEx

-

-

-

Maximum inner capacity Ci
Maximum inner inductance Li
Maximum input current Ii
Maximum input voltage Ui
Maximum input power Pi

-

-

-

Ordering data
Description

Voltage UN

TERMITRAB, modular terminal block with integrated surge protection, for mounting on NS 35
With disconnect knife
24 V DC
Without disconnect knife
24 V DC
Without disconnect knife
110 V AC

Type

Order No.

Pcs. /
Pkt.

TT-2-PE-M-24DC
TT-2-PE- 24DC
TT-2-PE-110AC

2920641
2838186
2858483

14
10
10

2920654
2838995

50
50

Accessories

94

PHOENIX CONTACT

Cover, for terminating a row of terminal blocks
For terminal blocks with disconnect knife
For terminal blocks without disconnect knife

TT-D-2-PE-M-BK
D-DEK 1,5 BK

Labeling material

ZB 6, see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
H

H
W

D

Double wire (loop), floating

H
W

D

2-wire, with common reference potential

Total width 6.2 mm

Total width 6.2 mm

1

OUT

IN

2

3

OUT

IN

2

4

3

1

OUT

IN

4

Technical data
... M-24DC
C1 / C2 / C3 / D1

Double wire (loop), intrinsically safe

Total width 6.2 mm

1

3

W

D

4

2

Technical data

Technical data

... 24DC
C1 / C2 / C3 / D1

... M-24DC
C1 / C2 / C3 / D1

... 24DC
C1 / C2 / C3 / D1

... M-24DC
C1 / C2 / C3 / D1

... 24DC
C1 / C2 / C3 / D1

30 V DC / 21 V AC

30 V DC / 21 V AC

30 V DC / 21 V AC

30 V DC / -

30 V DC / 21 V AC

30 V DC / -

500 A
10 A (40°C)

500 A
10 A (40°C)

500 A
300 mA (40°C)

500 A
300 mA (40°C)

500 A
250 mA (TA < 40 °C)

500 A
250 mA (40°C)

300 A / 5 kA
10 kA

300 A / 5 kA
10 kA

5 kA / 5 kA
10 kA

- / 5 kA
10 kA

5 kA / 5 kA
10 kA

5 kA / 5 kA
10 kA

≤ 45 V / ≤ 650 V

≤ 45 V / ≤ 700 V

- / ≤ 45 V

- / ≤ 50 V

≤ 44 V / ≤ 1.5 kV

≤ 50 V / ≤ 1.7 kV

Typ. 7 MHz / -

Typ. 6 MHz / -

- / Typ. 6 MHz
4.7 Ω

- / Typ. 1.5 MHz
6.6 Ω

Typ. 6 MHz / 4.7 Ω

Typ. 6 MHz / 4.7 Ω

6.2 mm / 92 mm / 66.45 mm
6.2 mm / 79.6 mm / 54.6 mm
0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
-40 °C ... 80 °C
IP20
V2
DIN EN 61643-21

6.2 mm / 92 mm / 66.45 mm
6.2 mm / 79.6 mm / 54.6 mm
0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
-40 °C ... 80 °C
IP20
V2
IEC 61643-21

-

-

-

-

-

-

-

-

-

-

-

-

Ordering data
Order No.

Pcs. /
Pkt.

TT-2-PE/S1-M-24DC
TT-2-PE/S1- 24DC

2920638
2839538

14
10

50
50

Order No.

Pcs. /
Pkt.

TT-2/2-M-24DC
TT-2/2- 24DC

2920722
2838173

14
10

TT-D-2-PE-M-BK
D-DEK 1,5 BK
ZB 6, see page 111

Ex ia IIC T4...T6 Ga
Ex ia IIIC T135°C...T85°C Da
2 nF
1 µH
250 mA (TA < 40 °C)
30 V
0.75 W

Ordering data
Type

Order No.

Pcs. /
Pkt.

TT-EX(I)-M-24DC
TT-EX(I)- 24DC

2803865
2832124

14
10

2803878
2838982

50
50

Accessories
2920654
2838995

KEMA 99ATEX5687 X

Ex ia IIC T4...T6 Ga
Ex ia IIIC T135°C...T85°C Da
2 nF
1 µH
250 mA
30 V
0.75 W

Type

Accessories

ZB 6, see page 111

KEMA 99ATEX5687 X

 II 1G Ex ia IIC T4...T6 Ga
 II 1G Ex ia IIC T4...T6 Ga
 II 1D Ex ia IIIC T135°C...T85°C Da  II 1D Ex ia IIIC T135°C...T85°C Da

Ordering data

Type

TT-D-2-PE-M-BK
D-DEK 1,5 BK

6.2 mm / 92 mm / 66.45 mm
6.2 mm / 79.6 mm / 54.6 mm
0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
-40 °C ... 80 °C
IP20
V2
IEC 61643-21 / EN 60079-0 / EN 60079-11 /

Accessories
2920654
2838995

50
50

TT-D-2-PE-M-BU
D-DEK 1,5 BU
ZB 6, see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

95

Surge protection and interference filters
Surge protection for measurement and control technology
Modular terminal blocks with
multiple stage surge protection
TERMITRAB
– Multi-stage modular terminal blocks with
spring-cage connection
– Versions with and without disconnect
knife
– Disconnection of signal circuits by disconnect knife

Notes:

H

For certifications, see page 154

W

D

TT-ST-M-EX(I)-24D
– Can be used in Ex protection zones 1
and 2
– Wires can be led through to Ex protection zone 0

Double wire (loop), floating

Total width 6.2 mm

1

3

OUT

IN

2

4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC

DC/AC

Lightning test curr. Iimp (10/350) µs
Per path
Nominal load current IL
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
Symmetrical/asymmetrical in the 50 Ω system
Resistance per path
Capacity per path
General data
Dimensions W/H/D (with disconnect knife)
Dimensions W/H/D (without disconnect knife)
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards
Safety data
EC-type examination certificate according to ATEX
Identification according to ATEX

... M...24AC
C1 / C2 / C3 /
D1
45 V DC /
31 V AC
1 kA
350 mA (45°C)

... M...24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
1 kA
350 mA (45°C)

... 24DC
C1 / C2 / C3 / D1

1 kA
350 mA (45°C)

5 kA / 5 kA
10 kA

5 kA / 5 kA
10 kA

5 kA / 5 kA
10 kA

≤ 55 V /
≤ 600 V

≤ 40 V /
≤ 600 V

≤ 40 V / ≤ 600 V

3.5 MHz / 6.6 Ω
2 pF

Typ. 3 MHz / 6.6 Ω
2 pF

3 MHz / 6.6 Ω
2 pF

30 V DC / 21 V AC

6.2 mm / 100 mm / 63.5 mm
6.2 mm / 100 mm / 63.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V2
IEC 61643-21/A1 / EN 61643-21/A1
-

-

-

Approvals according to IECEx

-

-

-

Maximum inner capacity Ci
Maximum inner inductance Li
Maximum input current Ii
Maximum input voltage Ui
Maximum input power Pi

-

-

-

Ordering data
Description

Voltage UN

Type

Order No.

Pcs. /
Pkt.

TT-ST-M-2-PE-24AC
TT-ST-M-2-PE-24DC
TT-ST-2-PE-24DC

2858920
2858904
2858878

10
10
10

2858894

50

TERMITRAB, spring-cage modular terminal block with integrated
surge protection disconnect knives, for mounting on NS 35
With disconnect knife
With disconnect knife
Without disconnect knife

24 V AC
24 V DC
24 V DC

Accessories
Cover, for terminating a row of terminal blocks
TT-D-STTCO-BK
Labeling material

96

PHOENIX CONTACT

ZB 6, see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
H

H
W

D

H
W

D

2-wire, with common reference potential

Total width 6.2 mm

Double wire (loop), floating

Double wire (loop), intrinsically safe

Total width 6.2 mm

1

3

2

Total width 6.2 mm

1

OUT

IN

W

D

3

OUT

IN

4

2

Technical data

1

OUT

IN

4

2

Technical data

4

Technical data

... M...24AC
C1 / C2 / C3 /
D1
45 V DC /
31 V AC
1 kA
300 mA (45°C)

... M...24DC
C1 / C2 / C3 /
D1
30 V DC /
21 V AC
1 kA
300 mA (45°C)

30 V DC / 21 V AC

30 V DC / 21 V AC

30 V DC / -

1 kA
300 mA (45°C)

500 A
6 A (40°C)

1 kA
200 mA (TA < 40 °C)

- / 5 kA
10 kA

- / 5 kA
10 kA

- / 5 kA
10 kA

300 A / 5 kA
5 kA

5 kA / 5 kA
10 kA

- / ≤ 55 V

- / ≤ 40 V

- / ≤ 40 V

≤ 45 V / ≤ 800 V

≤ 40 V / ≤ 1.5 kV

- / Typ. 3 MHz
9.4 Ω
2 nF

Typ. 3.3 MHz / -

Typ. 3 MHz / 6.6 Ω
-

6.2 mm / 100 mm / 63.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 80 °C
IP20
V0
IEC 61643-21/A1 / EN 61643-21/A1

6.2 mm / 100 mm / 63.5 mm
0.5 ... 4 mm² / 0.5 ... 2.5 mm² / 24 - 12
-40 °C ... 80 °C
IP20
V2
DIN EN 61643-21 / EN 60079-0 / EN 60079-11 /

- / Typ. 3.5 MHz - / Typ. 3 MHz
9.4 Ω
9.4 Ω
2 nF
2 nF

... 24DC
C1 / C2 / C3 / D1

3

C1 / C2 / C3 / D1

6.2 mm / 100 mm / 63.5 mm
6.2 mm / 100 mm / 63.5 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V2
IEC 61643-21/A1 / EN 61643-21/A1
-

-

-

-

-

-

-

-

-

-

-

-

KEMA 04ATEX1059 X

 II 1G Ex ia IIC T4...T6 Ga
 II 1D Ex ia IIIC T135°C...T85°C Da
Ex ia IIC T4...T6 Ga
Ex ia IIIC T135°C...T85°C Da
4 nF
1 µH
200 mA (T4/≤ 85°C)
30 V
1.6 W

Ordering data

Ordering data

Type

Order No.

Pcs. /
Pkt.

TT-ST-M-2/2-24AC
TT-ST-M-2/2-24DC
TT-ST-2/2-24DC

2858933
2858917
2858881

10
10
10

ZB 6, see page 111

Ordering data

Type

Order No.

Pcs. /
Pkt.

TT-ST-2-PE/S2-24DC

2801458

10

Accessories
TT-D-STTCO-BK

C1 / C2 / C3 / D1

Type

Order No.

Pcs. /
Pkt.

TT-ST-M-EX(I)-24DC

2859424

10

2856773

10

Accessories
2858894

50

TT-D-STTCO-BK
ZB 6, see page 111

Accessories
2858894

50

TT-D-ST-BU
ZB 6, see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

97

Surge protection and interference filters
Surge protection for measurement and control technology
TERMITRAB modular terminal block
with single-level surge protection

Notes:

H

For certifications, see page 154

D

– Modular terminal blocks with screw connection method
– Can be used as fine protection/medium
protection in the signal circuits of electronic controllers

W

With suppressor diode, direction of action:
core-ground

Total width 6.2 mm

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC

DC/AC

Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

... 12DC
C1 / C3
13 V DC /
9 V AC
32 A (50°C)

... 24DC
C3
28 V DC /
20 V AC
32 A (50°C)

... 48DC
C3
53 V DC / 37 V AC

- / 346 A
346 A

- / 169 A
169 A

- / 90 A
90 A

- / ≤ 19 V

- / ≤ 40 V

- / ≤ 80 V

32 A (50°C)

6.2 mm / 42.5 mm / 47 mm
0.2 ... 4 mm² / 0.2 ... 4 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V2
IEC 61643-21

Ordering data
Description

Voltage UN

TERMITRAB, modular terminal block with integrated surge protection, for mounting on NS 35
12 V DC
24 V DC
48 V DC
60 V DC

Type

Order No.

Pcs. /
Pkt.

TT-UK5/ 12DC
TT-UK5/ 24DC
TT-UK5/ 48DC

2794686
2794699
2794709

50
50
50

2794990

50

Accessories
Spacer plate, compensates for level offsets when normal terminal
blocks are aligned, 2.5 mm thick

98

PHOENIX CONTACT

Black
Cover, for terminating a row of terminal blocks
Black

D-TERMITRAB-UK 5

Labeling material

ZB 6, see page 111

Surge protection and interference filters
Surge protection for measurement and control technology
H

H
W

D

With suppressor diode, disconnect knife,
direction of action: core-core

Total width 6.2 mm

H
W

D

D

With suppressor diode, direction of action:
core-ground

Total width 6.2 mm

Technical data

W

With varistor, direction of action: core-ground

Total width 6.2 mm

Technical data

... 24DC
C3
28 V DC /
20 V AC
12 A (45°C)

... 48DC
C3
53 V DC /
37 V AC
12 A (45°C)

... 60DC
C3
70 V DC / 49 V AC

169 A / 169 A
≤ 40 V / -

Technical data

... 24DC
C3
28.2 V DC /
20 V AC
32 A (50°C)

... 48DC
C3
53 V DC / 37 V AC

12 A (45°C)

... 12DC
C1 / C3
13.6 V DC /
9.5 V AC
32 A (50°C)

... 24DC
C1 / C2 / C3
31 V DC /
11 V AC
32 A (50°C)

... 48DC
C1 / C2 / C3
65 V DC / 50 V AC

32 A (50°C)

... 12DC
C1 / C2 / C3
14 V DC /
11 V AC
32 A (50°C)

90 A / 90 A

69 A / 69 A

- / 346 A
346 A

- / 169 A
169 A

- / 90 A
90 A

- / 700 A
2 kA

- / 700 A
2 kA

- / 2 kA
6.5 kA

≤ 80 V / -

≤ 100 V / -

- / ≤ 19 V

- / ≤ 41 V

- / ≤ 79 V

- / ≤ 45 V

- / ≤ 80 V

- / ≤ 125 V

32 A (50°C)

6.2 mm / 80 mm / 68 mm
0.2 ... 4 mm² / 0.2 ... 4 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V2
IEC 61643-21 / DIN EN 61643-21

6.2 mm / 66.5 mm / 69.5 mm
0.2 ... 4 mm² / 0.2 ... 4 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V2
IEC 61643-21

6.2 mm / 66.5 mm / 69.5 mm
0.2 ... 4 mm² / 0.2 ... 4 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V2
IEC 61643-21

Ordering data

Ordering data

Ordering data

Type

Order No.

Pcs. /
Pkt.

TT-UKK5-M/ 24DC
TT-UKK5-M/ 48DC
TT-UKK5-M/ 60DC

2795960
2795973
2795986

50
50
50

Type

Order No.

Pcs. /
Pkt.

TT-SLKK5-S- 12DC
TT-SLKK5-S- 24DC
TT-SLKK5-S- 48DC

2809597
2809607
2809610

50
50
50

Accessories

ZB 6, see page 111

Type

Order No.

Pcs. /
Pkt.

TT-SLKK5/ 12DC
TT-SLKK5/ 24DC
TT-SLKK5/ 48DC

2794893
2794903
2794916

50
50
50

DP-UKK 3/5 BK

2770833

50

D-UKK 3/5 BK

2770228

50

Accessories

Accessories

DP-UKK 3/5 BK

2770833

50

D-UKK 3/5 BK

2770228

50

ZB 6, see page 111

ZB 6, see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

99

Surge protection and interference filters
Surge protection for measurement and control technology
Surge protection direct at the sensor
head
SURGETRAB
– Arresters in hexagonal tube with various
outer threads
– S-PT-1x2 and S-PT-EX(I) installation in signal path feed-through
– S-PT-EX, S-PT-2xEX..., and
S-PT-4-EX installation in a separate cable gland parallel to the signal cables
– S-PT-EX... devices are approved for Ex-i
and Ex-d measuring probes
Double wire (loop), floating

Double wire (loop), intrinsically safe

Notes:
For certifications, see page 154
For more information about EX approvals, visit
www.phoenixcontact.com
For additional safety data, visit www.phoenixcontact.com

Total width 34 mm

Total width 34 mm

1

BN

1

BN

2

BL

2

BL

IN

OUT

IN

OUT

BK

BK

Technical data
Electrical data
Maximum continuous operating voltage UC
DC/AC
Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Maximum permitted short-circuit current at installation location
Total surge current (8/20) µs
Protection level UP

Technical data

40 V DC / 28 V AC
1 kA
450 mA (55°C)

30 V DC / 21 V AC
1 kA
350 mA (50°C)

10 kA / 10 kA
1A

10 kA / 10 kA
350 mA

20 kA
Core-Core
Core-Ground

≤ 80 V (C2 -5 kA)

≤ 50 V (C3 - 25 A)
≤ 1.4 kV (C3 - 100 A)

≤ 55 V / ≤ 450 V (Direct grounding)
2.2 Ω

≤ 50 V / ≤ 1.4 kV (Direct grounding)
2.2 Ω

34 mm / 34 mm / 137 mm
-40 °C ... 85 °C
IP67
IEC 61643-21
-

34 mm / 34 mm / 137 mm
-40 °C ... 50 °C
IP67
DIN EN 61643-21 / EN 60079-0 / EN 60079-11 /
EN 60079-26

Safety data
EC-type examination certificate according to ATEX
Identification according to ATEX

-

 II 1G Ex ia IIC T4...T6 Ga

Maximum inner capacity Ci
Maximum inner inductance Li
Maximum input current Ii
Maximum input voltage Ui
Maximum input power Pi

-

2 nF
1 µH
350 mA (T4,T5,T6/≤ 50°C)
30 V
3W

Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Resistance per path
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Test standards

KEMA 06ATEX0002

Ordering data
Description

Voltage UN

SURGETRAB, protective adapter for installation on measuring
sensors
Outer thread: M20 x 1.5
24 V DC
Outer thread: 1/2'' 14 NPT
24 V DC
Outer thread: 3/4'' 14 NPT
24 V DC
SURGETRAB protective adapter for installation on measuring sensors for Ex protection zones
Outer thread: M20 x 1.5
24 V DC
Outer thread: 1/2'' 14 NPT
24 V DC
Outer thread: 3/4'' 14 NPT
24 V DC
Outer thread: M20 x 1.5
48 V DC
Outer thread: 1/2'' 14 NPT
48 V DC

100

PHOENIX CONTACT

Ordering data

Type

Order No.

S-PT-1X2-24DC
S-PT-1X2-24DC-1/2"
S-PT-1X2-24DC-3/4"

2880668
2882569
2882598

Pcs. /
Pkt.

Type

Order No.

S-PT-EX(I)-24DC
S-PT-EX(I)-24DC-1/2"
S-PT-EX(I)-24DC-3/4"

2880671
2882572
2882585

Pcs. /
Pkt.

1
1
1

1
1
1

Surge protection and interference filters
Surge protection for measurement and control technology

Double conductor (loop), floating,
intrinsically safe, encapsulated,
without decoupling resistance

2 double conductors (loops), floating,
intrinsically safe, encapsulated,
without decoupling resistance

Total width 28 mm

Total width 28 mm

BN

BN

BL

BL

/BK

/BK

RD

RD

˜

Total width 28 mm

4-wire with common reference potential,
intrinsically safe, encapsulated,
without decoupling resistance

+
˜

+

–
˜

BN

˜

–

˜

BL

/BK

+
˜

–

WH

WH

Technical data

Technical data

Technical data

... 24DC
36 V DC / 25 V AC
1 kA
-

... 48DC
53 V DC / 37 V AC
1 kA
-

... 24DC
36 V DC / 25 V AC
1 kA
-

... 48DC
53 V DC / 37 V AC
1 kA
-

36 V DC / 25 V AC
1 kA
-

260 A / 10 kA
1 A (non-EX)

170 A / 10 kA
1 A (non-EX)

260 A / 10 kA
1 A (non-EX)

170 A / 10 kA
1 A (non-EX)

260 A / 10 kA
1 A (non-EX)

20 kA

20 kA

20 kA

20 kA

20 kA

≤ 65 V (C3 - 10 A)
≤ 1.1 kV (C3 - 100 A)

≤ 90 V (C3 - 10 A)
≤ 1.1 kV (C3 - 100 A)

≤ 50 V (C3 - 10 A)
≤ 1.1 kV (C3 - 100 A)

≤ 80 V (C3 - 10 A)
≤ 1.1 kV (C3 - 100 A)

≤ 65 V (C3 - 10 A)
≤ 1.1 kV (C3 - 100 A)

≤ 60 V / -

≤ 80 V / -

≤ 50 V / -

≤ 80 V / -

≤ 60 V / -

28 mm / 28 mm / 79 mm
-25 °C ... 80 °C (non-EX)
IP67
EN 61643-21 / EN 60079-0 / EN 60079-1 /
EN 60079-11 / EN 60079-26 / EN 61241-0
KEMA 09ATEX0028 X

 II 1 G Ex ia IIC T4...T6
 II 2 G Ex d IIC T4...T6
1.65 nF
1 µH
500 mA
36 V DC
3W

28 mm / 28 mm / 79 mm
-25 °C ... 80 °C (non-EX)
IP67
EN 61643-21 / EN 60079-0 / EN 60079-1 /
EN 60079-11 / EN 60079-26 / EN 61241-0

KEMA 09ATEX0028 X
 II 1 G Ex ia IIC T4...T6
 II 2 G Ex d IIC T4...T6
1.14 nF
1 µH
500 mA
53 V DC
3W

KEMA 09ATEX0028 X
 II 1 G Ex ia IIC T4...T6
 II 2 G Ex d IIC T4...T6
1.65 nF
1 µH
500 mA
36 V DC
3W

Ordering data

28 mm / 28 mm / 79 mm
-25 °C ... 80 °C (non-EX)
IP67
EN 61643-21 / EN 60079-0 / EN 60079-1 /
EN 60079-11 / EN 60079-26 / EN 61241-0

KEMA 09ATEX0028 X
 II 1 G Ex ia IIC T4...T6
 II 2 G Ex d IIC T4...T6
1.14 nF
1 µH
500 mA
53 V DC
3W

KEMA 09ATEX0028 X
 II 1 G Ex ia IIC T4...T6
 II 2 G Ex d IIC T4...T6
1.65 nF
1 µH
500 mA
36 V DC
3W

Ordering data

Type

Order No.

S-PT-EX-24DC
S-PT-EX-24DC-1/2"

2800034
2800035

S-PT-EX-48DC
S-PT-EX-48DC-1/2"

2800053
2800054

Pcs. /
Pkt.

Ordering data
Pcs. /
Pkt.

Type

Order No.

1
1

S-PT-2XEX-24DC
S-PT-2XEX-24DC-1/2"

2800040
2800041

1
1

1
1

S-PT-2XEX-48DC
S-PT-2XEX-48DC-1/2"

2800038
2800039

1
1

Type

Order No.

S-PT-4-EX-24DC
S-PT-4-EX-24DC-1/2"

2800036
2800037

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1
1

101

Surge protection and interference filters
Surge protection for measurement and control technology
COMTRAB modular

– Modular compact protection for highdensity networks
– Space-saving LSA-PLUS connection technology
– Surge protection connectors for 1 - 10
double wires or 2 - 20 individual wires
– Typical installation locations include marshalling distributors
– Can be used in LSA-PLUS disconnect and
control strips or CT-TERMIBLOCK
– The CTM 10-MAG surge protection card
cage can be mounted with any of the different protective connectors

Double wire (loop), floating

2-wire, with common reference potential

Total width 9.5 mm

Notes:

Total width 9.5 mm

For certifications, see page 154
1'

1

IN

OUT

2

IN

OUT

2

2'

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC

DC/AC

Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core
Core-Ground
Cut-off frequency fg (3 dB)
Symmetrical/asymmetrical in the 100 Ω system
Resistance per path
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

Description

Voltage UN

1'

1

2'

Technical data

... 12DC
B2 / C1 / C2 /
C3 / D1
± 15 V DC /
10 V AC
1 kA
380 mA (25°C)

... 24DC
B2 / C1 / C2 /
C3 / D1
± 30 V DC /
21 V AC
1 kA
380 mA (25°C)

... 60DC
B2 / C1 / C2 /
C3 / D1
± 65 V DC /
50 V AC
1 kA
380 mA (25°C)

5 kA / 5 kA
10 kA

5 kA / 5 kA
10 kA

≤ 25 V
≤ 700 V
1.2 MHz / 3.3 Ω

... 110AC
B2 / C1 / C2 /
C3 / D1
± 180 V DC / 1 kA
380 mA (25°C)

... 5DC
B2 / C1 / C2 /
C3 / D1
± 6 V DC /
5 V AC
1 kA
380 mA (25°C)

... 12DC
B2 / C1 / C2 /
C3 / D1
± 15 V DC /
10 V AC
1 kA
380 mA (25°C)

... 24DC
B2 / C1 / C2 /
C3 / D1
± 30 V DC /
21 V AC
1 kA
380 mA (25°C)

... 60DC
B2 / C1 / C2 /
C3 / D1
± 65 V DC /
50 V AC
1 kA
380 mA (25°C)

5 kA / 5 kA
10 kA

5 kA / 5 kA
10 kA

- / 5 kA
10 kA

- / 5 kA
10 kA

- / 5 kA
10 kA

- / 5 kA
10 kA

≤ 70 V
≤ 700 V

≤ 160 V
≤ 700 V

≤ 260 V
≤ 800 V

≤ 12 V

≤ 22 V

≤ 45 V

≤ 160 V

2.7 MHz / 3.3 Ω

2 MHz / 3.3 Ω

20 MHz / 3.3 Ω

- / 700 kHz
3.3 Ω

- / 1.5 MHz
3.3 Ω

- / 2.7 MHz
3.3 Ω

- / 2 MHz
3.3 Ω

9.5 mm / 21 mm / 53.5 mm
-25 °C ... 75 °C
IP20
V0
IEC 61643-21

9.5 mm / 21 mm / 53.5 mm
-25 °C ... 75 °C
IP20
V0
IEC 61643-21

Ordering data

Ordering data

Type

Order No.

Pcs. /
Pkt.

CTM 1X2- 12DC
CTM 1X2- 24DC
CTM 1X2- 60DC
CTM 1X2-110AC

2838597
2838513
2838568
2838539

10
10
10
10

Type

Order No.

Pcs. /
Pkt.

CTM 2X1- 5DC
CTM 2X1- 12DC
CTM 2X1- 24DC
CTM 2X1- 60DC

2838571
2838584
2838500
2838542

10
10
10
10

2838610

5

COMTRAB modular, surge protection for a double wire with
coarse and fine protection and ohmic decoupling, DSL-compatible
5 V DC
12 V DC
24 V DC
60 V DC
110 V AC
180 V DC

Accessories

Accessories

Magazine, with grounding rail for accommodating up to
10 LSA-PLUS protective connectors (CTM...), for insertion in
CT-TERMIBLOCK or LSA-PLUS disconnect strip
CTM 10-MAG

102

PHOENIX CONTACT

2838610

5

CTM 10-MAG

Surge protection and interference filters
Surge protection for measurement and control technology

16.000

2-wire, with common reference potential

Total width 9.5 mm

2-wire, coarse protection, with failsafe contact

2-wire, coarse protection, with failsafe contact
and current protection (Powercross)

Total width 9.5 mm

Total width 9.5 mm

1'

1

1

1'

1

J

J

IN

OUT

OUT

IN

OUT

IN
J

J

2

2

2'

Technical data

2

2'

Technical data

B2 / C1 / C2 / C3 / D1

A2 / B1 / B2 / B3 / C1 / C2 / C3 / D1 / D2

± 180 V DC / -

± 180 V DC / -

± 180 V DC / -

1 kA
380 mA (25°C)

1 kA
1.5 A (25°C)

1 kA
120 mA (25 °C)

- / 5 kA
10 kA

- / 5 kA
10 kA

- / 5 kA
10 kA

≤ 15 V

≤ 800 V

≤ 800 V

- / Typ. 20 MHz
3.3 Ω

- / > 100 MHz
-

- / > 100 MHz
5.5 Ω

9.5 mm / 21 mm / 53.5 mm
-25 °C ... 75 °C
IP20
V0
IEC 61643-21

9.5 mm / 21 mm / 53.5 mm
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

9.5 mm / 21 mm / 53.5 mm
-40 °C ... 85 °C
IP20
V0
IEC 61643-21

Ordering data

Type

Order No.

Pcs. /
Pkt.

CTM 2X1-110AC

2838526

10

Type

CTM 2X1-180DC-GS

Accessories

CTM 10-MAG

Ordering data
Order No.

Pcs. /
Pkt.

2838636

10

Type

CTM 2X1-180DC-GS-P

Accessories

2838610

5

CTM 10-MAG

2'

J

Technical data

A2 / B1 / B2 / B3 / C1 / C2 / C3 / D1 / D2

Ordering data

1'

J

Order No.

Pcs. /
Pkt.

2838623

10

2838610

5

Accessories

2838610

5

CTM 10-MAG

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

103

Surge protection and interference filters
Surge protection for measurement and control technology
COMTRAB modular

CTM ISDN
– Tailored to the ISDN bus with basic and
primary multiplex connections
– Two protective connectors are required
to protect the ISDN bus
CTM EST
– Grounding plug to short circuit and
ground the wires
Double wire (loop), ISDN So
(2 connectors are required for one bus)

Notes:

LSA-PLUS grounding plug

For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

Total width 9.5 mm

Total width 9.5 mm
1'

1

OUT

IN

2

OUT

IN

2

2'

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Lightning test curr. Iimp (10/350) µs
Per path
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
Symmetrical in the 100 Ω system
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

Voltage UN

2'

Technical data

B2 / C2 / C3 / D1 / C1
± 6 V DC
1 kA
1.5 A (25 °C)

1.5 A (25 °C)

350 A / 5 kA
10 kA

-/10 kA

≤ 15 V / ≤ 700 V

-

≥ 100 MHz

-

9.5 mm / 21 mm / 53.5 mm
-25 °C ... 75 °C
IP20
V0
IEC 61643-21

9.5 mm / 21 mm / 53.5 mm
-25 °C ... 75 °C
IP20
V0
-

Ordering data
Description

1'

1

Ordering data

Type

Order No.

Pcs. /
Pkt.

CTM ISDN

2838555

10

Type

Order No.

Pcs. /
Pkt.

CTM EST

2838649

10

COMTRAB modular, surge protection for the ISDN-S0 interface
6 V DC
COMTRAB modular, LSA-PLUS grounding plug to short-circuit
and ground potentials in CT-TERMIBLOCK... and disconnect strip
CT 10...

104

PHOENIX CONTACT

Surge protection and interference filters
Surge protection for measurement and control technology
COMTRAB

– Multi-position, plug-in modular design
– For use with CT-TERMIBLOCK and with
LSA-PLUS and LSA-PROFIL disconnect
and control strips
– Specially designed for higher signal voltages of 120 V and 230 V
– For controllers with a large number of signal inputs and outputs, such as those used
in remote control technology or traffic
light systems
– Protection modules must be inserted in
the correct direction

For 9 wires with common reference potential

Notes:
Total width 111 mm

For certifications, see page 154

1... 9

1... 9

J

10

10

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
DC/AC
Nominal current IN
Nominal discharge surge current In (8/20) µs
GND-Ground / Core-GND
Total surge current (8/20) µs
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94

C1 / C3
275 V DC / 275 V AC
1.5 A
5 kA / 1.5 kA
5 kA
111 mm / 22 mm / 68.5 mm
-40 °C ... 85 °C
IP20
V2

Ordering data
Description

Voltage UN

Type

Order No.

Pcs. /
Pkt.

COMTRAB, LSA-PLUS plug with surge protection incl. optical fault
warning for nine signal circuits
230 V AC

CT 10-9VA-230AC

2830498

1

0441711

10

Accessories
Screw terminal block, with disconnect contacts for accommodating the CT and CTM protective connectors, design: 10 double wires
CT-TERMIBLOCK 10 DA

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

105

Surge protection and interference filters
Surge protection for measurement and control technology
COMTRAB

Notes:
For certifications, see page 154

– Multi-position, plug-in modular design
– For use with CT-TERMIBLOCK and with
LSA-PLUS and LSA-PROFIL disconnect
and control strips
– Applications include systems with higher
signal voltages
– Combined protective circuits
– Protection modules must be inserted in
the correct direction
For 10 double conductors, floating,
without decoupling resistance

Total width 111 mm
1.../19

1'.../19’

OUT

IN

2.../20

2'.../20’

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
DC/AC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Resistance per path
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

C1 / C2 / C3 / D1
40 V DC / 28 V AC
1.5 A (75°C)
119 A (25°C) / 5 kA
10 kA
≤ 60 V / ≤ 650 V
111 mm / 22 mm / 68.5 mm
-25 °C ... 75 °C
IP20
V0
IEC 61643-21

Ordering data
Description

Voltage UN

Pcs. /
Pkt.

Type

Order No.

CT 10-2PE/FS-24

2807955

1

0441711

10

COMTRAB, surge arrester modules for use in CT-TERMIBLOCK
and LSA-PLUS or LSA-PROFIL disconnect and control strips
Without decoupling
With decoupling

24 V DC
24 V DC

Accessories
Screw terminal block, with disconnect contacts for accommodating the CT and CTM protective connectors, design: 10 double wires
CT-TERMIBLOCK 10 DA

106

PHOENIX CONTACT

Surge protection and interference filters
Surge protection for measurement and control technology

For 10 double wires, floating, with decoupling

Total width 111 mm

For 18 conductors with common reference
potential, without decoupling resistance

Total width 111 mm

1.../19

OUT

IN

2.../20

Total width 111 mm

1.../17

1'.../19’

1.../17

1'.../17'

19 / 20
GND
OUT
19' / 20'

IN

2.../18

2'.../20’

Technical data

For 18 conductors with common reference potential, with decoupling

1'.../17'

19 / 20
GND
OUT
19' / 20'

IN

2.../18

2'.../18'

Technical data

2'.../18'

Technical data

C1 / C2 / C3 / D1
40 V DC / 28 V AC
200 mA (25°C)

C1 / C2 / C3 / D1
40 V DC / 28 V AC
1.5 A (75°C)

C1 / C2 / C3 / D1
40 V DC / 28 V AC
140 mA (25°C)

5 kA / 5 kA
10 kA

214 A (25°C) / 5 kA
10 kA

5 kA / 5 kA
10 kA

≤ 60 V / ≤ 650 V
10 Ω

- / ≤ 650 V
-

- / ≤ 650 V
22 Ω

111 mm / 22 mm / 68.5 mm
-25 °C ... 75 °C
IP20
V0
IEC 61643-21

111 mm / 22 mm / 68.5 mm
-25 °C ... 75 °C
IP20
V0
IEC 61643-21

111 mm / 22 mm / 68.5 mm
-25 °C ... 75 °C
IP20
V0
IEC 61643-21

Ordering data

Ordering data

Type

Order No.

CT 10-2PE/FSR-24

2807968

Pcs. /
Pkt.

Type

Order No.

CT 10-18FS+F/PE-24

2807926

Pcs. /
Pkt.

Type

CT 10-18FSR+F/PE-24

Accessories

0441711

10

Order No.

CT-TERMIBLOCK 10 DA

Pcs. /
Pkt.

1

1

Accessories

CT-TERMIBLOCK 10 DA

Ordering data

2807939

1

0441711

10

Accessories

0441711

10

CT-TERMIBLOCK 10 DA

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

107

Surge protection and interference filters
Surge protection for measurement and control technology
LSA-PLUS coarse protection
magazine
– For use in CT-TERMIBLOCK or in
LSA-PLUS and LSA-PROFIL disconnect
and terminal strips
CT 10-2/2-GS
– For fitting with 20 two-electrode arresters filled with inert gas
– Common mode voltage coarse protection for 20 signal wires
CT ...-2/2-GS/3E
– Fitted with up to 10 three-electrode arresters filled with inert gas
– When the gas-filled arrester is triggered,
the potentials of the three connections ab- are equalized
– Coarse protection both in the normal
mode voltage branch and the common
mode voltage branch for 10 double wires

For 10 double wires (loops) and 20 two-electrode GDTs

Total width 113 mm

For 10 double wires (loops) and 10 three-electrode GDTs

Total width 113.3 mm

b1

b2

b3

b4

b5

b8/b10

b1

b2

b3

b4

b5

b8/b10

a1

a2

a3

a4

a5

a8/a10

a1

a2

a3

a4

a5

a8/a10

Notes:
For dimensional drawings, see www.phoenixcontact.net/products

Ordering data
Description

Voltage UN

Ordering data

Type

Order No.

CT 10-2/2-GS

2765398

Pcs. /
Pkt.

Pcs. /
Pkt.

Type

Order No.

CT 10-2/2-GS/3E

2765408

5

CT 10-2/2-GS/3E-110AC

2920829

10

2765521

10

Coarse protection magazine, to accommodate 20 two-electrode
gas-filled surge arresters, design H, bare, model: 10 double conductors
5

Coarse protection card cage, for 10 double conductors
unassembled, for accommodating 10 three-electrode gas-filled surge arresters
assembled, with 10 three-electrode gas-filled
110 V AC
surge arresters

Accessories

Accessories

2-electrode gas-filled surge arrester filled with inert gas,
type H, for use in CT 10-2/2-GS coarse protection magazine
48 V AC
110 V AC
3-electrode gas-filled surge arrester filled with inert gas,
for use in CT 10-2/2-GS/3E coarse protection magazine
110 V AC

108

PHOENIX CONTACT

SVP 2E- 48AC
SVP 2E-110AC

2788919
2765534

10
10

SVP 3E-110AC

Surge protection and interference filters
Surge protection for measurement and control technology
CT-TERMIBLOCK

Notes:

H

For dimensional drawings, see www.phoenixcontact.net/products

D

– Screw terminal block
– For COMTRAB protective connectors
– Automatically closing feed-through/disconnect contacts
– Ground terminal blocks on both sides
with plug-in connection for the protective
connectors used
– Mounting on DIN rails according to
EN 60715

W

For accommodating the CT and CTM
protective connectors, with screw connection
Technical data
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94

118 mm / 43 mm / 40.9 mm
0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
-40 °C ... 85 °C
IP20
V2

Ordering data
Description

Type

Order No.

Pcs. /
Pkt.

0441711

10

0828492

1

Screw termination block with disconnect contacts for accommodating the protective plugs CT and CTM, model: 10 double conductors
CT-TERMIBLOCK 10 DA

Accessories
Marker strips, self-adhesive, color: white, can be labeled according to customer specifications
SK CUS

COMTRAB modular magazine

Notes:
For dimensional drawings, see www.phoenixcontact.net/products

– For accommodating up to 10 protective
connectors
– Integrated grounded rail for connecting
the CTM connectors to equipotential
bonding

Magazine for 10 CTM
Technical data
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94

112.5 mm / 21.8 mm / 44 mm
-25 °C ... 75 °C
IP20
V0

Ordering data
Description

Type

Order No.

CTM 10-MAG

2838610

Pcs. /
Pkt.

Magazine, with a grounding rail to accommodate up to
10 LSA-PLUS protective plugs (CTM...), to insert in
CT-TERMIBLOCK or LSA-PLUS disconnect strip

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

5

109

Surge protection and interference filters
Surge protection for measurement and control technology
COMTRAB disconnect strip

Notes:
For dimensional drawings, see www.phoenixcontact.net/products

– LSA-PLUS disconnect strip
– For COMTRAB protective connectors
– For up to 10 CTM connectors

For accommodating the CT and CTM protective connectors, with LSA-PLUS connection
Ordering data
Description

Type

Order No.

CT 10-TL

2765356

Pcs. /
Pkt.

LSA-PLUS disconnect strip to hold the CTM and CT 10 protection modules, model: 10 double conductors

COMTRAB grounding rails and
mounting clips

5

Notes:
For dimensional drawings, see www.phoenixcontact.net/products

CT 1-10-ES
– For grounding up to 10 x 1DA CTM protective connectors
CT 10-MB...
– For accommodating 3 or 10 x LSA-PLUS
disconnect or ground wire strips

Grounded rail/mounting clip

Ordering data
Description

Type

Order No.

Pcs. /
Pkt.

CT 1-10-ES

2765547

10

CT 10-MB/ 3

2765372

2

CT 10-MB/10

2765385

2

CT-KDT

2765518

10

Ground rail for CTM protective plug when used in combination
with LSA-PLUS disconnect strip, model: 10 double conductors

Mounting clip, for holding 3 disconnect or ground wire strips,
model: 10 double conductors

Mounting clip, for holding 10 disconnect or
ground wire strips, model: 10 double conductors

Cable feed-through sleeve for assembly troughs,
for protection of the lines guided through the laminated frame

110

PHOENIX CONTACT

Surge protection and interference filters
Surge protection for measurement and control technology
Shield fast connection and labeling
material
SSA
– For connecting cable shielding to cable
terminal points
– Can be connected to PLUGTRAB PT
– Easy assembly
ZB...
– For clear and logical identification
– The multi-section ZB strips can be easily
separated
– Individual labeling of unlabeled ZB strips

Shield fast connection

Labeling material

Total width 6 mm

Ordering data
Description
Shield fast connection
For Ø 3 - 6 mm
For Ø 5 - 10 mm
UniCard sheets, for 6.2 mm terminal block width, 80-section, can
be labeled with BLUEMARK
White
Orange
Yellow
Blue
Red
Green
UniCard sheets, for 12 mm terminal block width,
40-section, can be labeled with BLUEMARK

Type

SSA 3-6
SSA 5-10

Ordering data
Order No.

Pcs. /
Pkt.

2839295
2839512

10
10

Type

UC-TM
UC-TM
UC-TM
UC-TM
UC-TM
UC-TM

6
6 OG
6 YE
6 BU
6 RD
6 GN

Order No.

Pcs. /
Pkt.

0818085
0818328
0818331
0818344
0818357
0818360

10
10
10
10
10
10

White
Orange
Yellow
Blue
Red
Green
Zack marker strip, 10-section, unprinted
White
White
White
Zack marker strip, printed horizontally, 10section, with consecutive numbers, e.g. 1-10, 1120, etc. up to 91-100
White
White
Zack marker strip, 10-section, printed horizontally: With L1, L2,
L3, N, PE
White
White
White
Zack marker strip, flat, 10-section, without color print
White
White
White
White
Zack marker strip, 10-section, printed horizontally: with consecutive numbers, e.g., 1 - 10, 11 - 20 and so on up to 91 - 100

UC-TM 12
UC-TM 12 OG
UC-TM 12 YE
UC-TM 12 BU
UC-TM 12 RD
UC-TM 12 GN

0819194
0817691
0819204
0817785
0817701
0817808

10
10
10
10
10
10

ZB 5 :UNBEDRUCKT
ZB 6:UNBEDRUCKT
ZB 12:UNPRINTED

1050004
1051003
0812120

10
10
10

ZB 5,LGS:FORTL.ZAHLEN
ZB 6,LGS:FORTL.ZAHLEN

1050017
1051016

10
10

ZB 5,LGS:L1-N,PE
ZB 6,LGS:L1-N,PE
ZB 12,LGS:L1-N,PE

1050415
1051414
0812146

10
10
10

ZBF 5:UNBEDRUCKT
ZBF 6:UNBEDRUCKT
ZBF 12:UNBEDRUCKT
ZBF 15:UNBEDRUCKT

0808642
0808710
0809735
0811202

10
10
10
10

White
White

ZBF 5,LGS:FORTL.ZAHLEN
ZBF 6,LGS:FORTL.ZAHLEN

0808671
0808749

10
10

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

111

Surge protection and interference filters
Surge protection for information technology and telecommunications

Low signal levels at high frequencies require special protective circuits in data processing and telecommunications. The arresters must guarantee short reaction times
to quickly limit the surge voltages to safe
values, without impairing signal quality. In
addition, the protective devices support
system-specific connections, such as RJ45
or D-SUB connectors, and all types of network topology.

112

PHOENIX CONTACT

DATATRAB DT - The all-round solution for protecting data interfaces
DATATRAB DT reliably protects highspeed networks against damage caused by
surge voltages. DT-LAN-CAT.6+ supports
various data protocols at very high transmission speeds, such as Ethernet, Power
over Ethernet (PoE), ISDN, token ring, and
DS1, in a single device.
The housing has a ground connection
snap-on foot into which the ground connection cover with equipotential bonding cable
is inserted. DATATRAB can be therefore
used either as an adapter or a DIN rail module after removing the ground connection
cover.

Surge protection and interference filters
Surge protection for information technology and telecommunications

Use
Protective devices suitable for all common applications including Ethernet, token
ring, CDDI, ISDN, DS1, DSL, analog telecommunications, RS-485, RS-232, V.11, etc.
are available.
The circuit breakers also support Power
over Ethernet (PoE) in Mode A and B versions.

Speed
Used in EDP systems with a transmission
speed of up to 10 Gbps (CAT.6/CLASS Ea)
and in telecommunications networks with
16 Mbps (ADSL2+).

Versatile
The DATATRAB product range can offer
a suitable protective device for many and
varied applications. The protective devices
are simply installed between the signal paths
with interfaces for RJ11/12, RJ45, D-SUB, or
screw connection.

Other designs
Other application-specific protective devices include:
– Two-part plug-in protective devices in the
PLUGTRAB product range
– Combined adapters for the power supply
and MAINTRAB interfaces
– Narrow plug-in arresters for COMTRAB
modular marshalling distributors

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

113

Surge protection and interference filters
Surge protection for information technology and telecommunications
Surge protection for Ethernet/
PROFINET networks with twisted
pair cabling
DT-LAN-CAT.6+
– Suitable for category 6 high-speed data
networks
– Reliable transmission rates up to 10 Gbps
– Protective adapter for eight signal paths
via RJ45 connector
– Can be installed in a control cabinet by removing a ground connection adapter

Notes:

H

For certifications, see page 154

D-LAN-CAT.5-FP
– Suitable for category 5 data networks
– Reliable transmission speeds up to 1 Gbps
– Protective adapter for eight signal paths
via RJ45 connector
–
–
–
–
–
–

–
–
–
–

D-LAN-19“
19" rack for installation in storey distributors
Up to 24 ports with RJ45 connection
Reliable transmission speeds up to 1 Gbps
Protection of all eight signal wires of the
data cable
Indirect grounding via a gas-filled surge arrester in the housing
Direct grounding via a connection on the
housing
DATA-PLUGTRAB PT 5-HF
Protection for up to five signal wires
For high transmission speeds
High discharge capacity
Connectors can be checked with
CHECKMASTER

* Note: PT .x.-BE connections 9/10
(GND) are linked directly to the mounting
foot.

W

D

For LAN interfaces (Class EA/CAT 6) including
PoE and ISDN S0 protection

Total width 25 mm

1

2

3

6 OUT 4

5

7

8

1

2

3

6 IN 4

5

7

8

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core / Core-Ground

B2 / C1 / C2 / C3 / D1
≤ 3.3 V DC (± 60 V DC/PoE+)
≤ 1.5 A (25°C)
100 A / 2 kA (per signal pair)
10 kA
≤ 9 V (B2 - 1 kV/25 A) / ≤ 700 V (C2 - 4 kV/2 kA)

Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 100 Ω system
Symmetrical
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method

≤ 9 V / ≤ 700 V

25 mm / 103 mm / 63 mm
-40 °C ... 70 °C
IP20
RJ45

Test standards

IEC 61643-21 / EN 50173-1 / ISO/IEC 11801-Am.1

> 500 MHz

Ordering data
Description

Pcs. /
Pkt.

Type

Order No.

DT-LAN-CAT.6+

2881007

1

FL CAT6 PATCH 1,0

2891385

10

DATATRAB adapter, protective adapter to be inserted into the
data line
DATATRAB, for use in Ethernet, token ring, FDDI/CDDI in acc. with
Cat.D/CAT5e EN 50173 (1000Base-T)
24 ports
20 ports
16 ports
12 ports
8 ports
4 ports
Surge protection PCB as replacement or for retrofitting in D-LAN19"... products incl. RJ45 sockets
4 ports
Patch cable, CAT6, preassembled
PLUGTRAB plug, with protection circuit for plugging into base element PT
PLUGTRAB base element, for mounting on NS 35
Bridge between 3/4 () and 9/10

114

PHOENIX CONTACT

Surge protection and interference filters
Surge protection for information technology and telecommunications
H

H
W

D

For LAN interfaces (Class D/CAT 5) including
PoE and ISDN S0 protection

Total width 28 mm

2

For data interfaces, with RJ45 connection
Class D/CAT5e

Total width 483 mm

3

6 OUT 4

5

7

1

8

Plug-in arrester with screw connection, for five
conductors, with common reference potential

Total width 17.7 mm

2 3 4 5 6

7

OUT
OUT

8

1

2

5

6

7

8

11

12

OUT

IN

J1

J2

1

W

D

9

1

2

3

6 IN 4

5

7

8

2 3 4 5 6

1

Technical data

IN
IN

7

3

8

Technical data

*

10
4

Technical data

B2 / C1
≤ 5 V DC (±57 V DC/PoE)
≤ 1.5 A (25°C)

C1 / C2 / C3 / B3
6 V DC
1.5 A (25°C)

C1 / C2 / C3 / D1
5.2 V DC / 3.6 V AC
450 mA (45°C)

350 A / 350 A
-

350 A / 350 A
10 kA

10 kA / 10 kA
20 kA

≤ 35 V (C1 - 700 V/350 A) ≤ 110 V (C1 - 700 V/350 A - PoE) / -

≤ 50 V (C1, 500 V/250 A) / ≤ 40 V (C1, 500 V/250 A (J2 ON))

≤ 34 V (C3 - 25 A) / ≤ 34 V (C3 - 25 A)

≤ 25 V / ≤ 750 V

≤ 20 V / ≤ 30 V (J2 plugged)

≤ 15 V / ≤ 15 V

> 100 MHz

> 100 MHz

Typ. 70 MHz

28 mm / 110 mm / 60 mm
-40 °C ... 85 °C
IP20
V0
RJ45

483 mm / 44 mm / 160 mm
-40 °C ... 80 °C
IP20
RJ45

17.7 mm / 90 mm / 65.5 mm
-40 °C ... 85 °C
IP20
V0
Screw connection (in connection with the base element)

IEC 61643-21/A1 / GB/T 18802.21 / EN 61643-21/A1

IEC 61643-21

IEC 61643-21/A1 / EN 61643-21/A1

Ordering data

Ordering data

Type

Order No.

D-LAN-CAT.5-FP

2800723

FL CAT6 PATCH 1,0

2891385

Pcs. /
Pkt.

Ordering data
Pcs. /
Pkt.

Type

Order No.

D-LAN-19"-24
D-LAN-19"-20
D-LAN-19"-16
D-LAN-19"-12
D-LAN-19"-8
D-LAN-19"-4

2838791
2880134
2880147
2880150
2880163
2880176

1
1
1
1
1
1

D-LAN-19"-D-P

2880192

1

Type

Order No.

Pcs. /
Pkt.

PT 5-HF- 5 DC-ST

2838762

10

PT 2X2-BE

2839208

10

1

10

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

115

Surge protection and interference filters
Surge protection for information technology and telecommunications
Protection for RS-232
interfaces

Notes:

H

For certifications, see page 154

DT-UFB-V24/S
– Connection: 9-pos. D-SUB and 25-pos.
D-SUB
– For data and handshake cables
–
–
–
–

PLUGTRAB PT 3-HF-12DC
Connection: Screw terminal blocks
For high transmission speeds
High discharge capacity
Connectors can be checked with
CHECKMASTER

Protective adapter with 9-pos. D-SUB

Pin assignment DT-UFB-V24/S-9-SB
– 1,2,3,4,6,7,8,9 Data lines
–5
Signal ground (Ground)

Total width 25 mm

Pin assignment
DT-UFB-V24/S-SB-SET
– 2,3,4,5,6,8,20,22 data lines
–7
Signal ground (Ground)

IN

Pin assignment PT 3-HF-12DC:
– 7.11 Data lines
– 9 Signal ground (Ground)
–3

* Note: PT .x.+F-BE connections 9/10
(GND) are linked to the mounting foot via
a gas-filled surge arrester.

W

D

1

1

2

2

3

3

4

4

6

6

7

7

8

8

9

9

5

5

OUT

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs

B2 / C1 / C2 / C3
15 V DC / 10 V AC
≤ 1 A (25°C)
Core-Earth/Core-GND

Total surge current (8/20) µs
Protection level UP

≤ 250 A / ≤ 250 A
5 kA

Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 100 Ω system
Symmetrical / Asymmetrical
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method

≤ 55 V (C1 - 250 A) / ≤ 450 V (C1 - 250 A)

25 mm / 110 mm / 63 mm
-40 °C ... 85 °C
IP20
D-SUB-9

Test standards

DIN EN 61643-21 / IEC 61643-21

Typ. 2.5 MHz / Typ. 1.3 MHz

Ordering data
Description

Type

Order No.

DT-UFB-V24/S-9-SB

2803069

Pcs. /
Pkt.

DATATRAB-Adapter, protective adapter for inserting into the data
line for protecting the RS-232 interface with D-SUB-9 connector

DATATRAB-Adapter, protective adapter for inserting into the data
line for protecting the RS-232 interface with D-SUB-25 adapter
cable
PLUGTRAB plug, with protection circuit for plugging into base element PT
PLUGTRAB base element, for mounting on NS 35
with a gas-filled surge arrester between the 3/4 () and the 9/10
connections

Accessories
Labeling material

116

PHOENIX CONTACT

1

Surge protection and interference filters
Surge protection for information technology and telecommunications
H

H
W

D

W

D

Protective adapter with 9-pos. D-SUB and
adapter cable with 25-pos. D-SUB

Total width 25 mm

Plug-in arrester with screw connection,
for three conductors, with common reference
potential

Total width 17.7 mm

8

8

3

3

2

2

20

7

8

11

12

9

10

20

6

6

IN 4

4

5

5

22

OUT

OUT

IN

22

7

*

3

7

Technical data

4

Technical data

B2 / C1 / C2 / C3
15 V DC / 10 V AC
≤ 1 A (25°C)

C1 / C2 / C3 / D1
14 V DC / 9.8 V AC
450 mA (45°C)

≤ 250 A / ≤ 250 A
5 kA

10 kA / 10 kA
20 kA

≤ 55 V (C1 - 250 A) / ≤ 450 V (C1 - 250 A)

≤ 45 V (C3 - 25 A) / ≤ 45 V (C3 - 25 A)

Typ. 2.5 MHz / Typ. 1.3 MHz

Typ. 70 MHz / -

25 mm / 110 mm / 63 mm
-40 °C ... 85 °C
IP20
D-SUB-25

17.7 mm / 90 mm / 65.5 mm
-40 °C ... 85 °C
IP20
V0
Screw connection (in connection with the base element)

DIN EN 61643-21 / IEC 61643-21

IEC 61643-21/A1 / EN 61643-21/A1

Ordering data

Ordering data

Type

Order No.

DT-UFB-V24/S-SB-SET

2803072

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

PT 3-HF-12DC-ST

2858043

10

PT 1X2+F-BE

2856126

10

1

Accessories

Accessories
ZBF ..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

117

Surge protection and interference filters
Surge protection for information technology and telecommunications
Surge protection for V.11/RS-422
interfaces

Notes:

H

For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

– For floating signal circuits or signal cables
– For high data transmission rates
– Connectors can be checked with
CHECKMASTER
Pin assignment PT 5-HF-12DC:
– 1,5 Data line pair 1: T(A), T(B)
– 7,11 Data line pair 2: R(A), R(B)
–9
Signal ground (Ground)
–3


W

D

Plug-in arrester with screw connection, for five
conductors, with common reference potential

* Note: PT .x.+F-BE connections 9/10
(GND) are linked to the mounting foot via
a gas-filled surge arrester.

Total width 17.7 mm
1

2

5

6

7

8

11

12

OUT

IN

9
3

*

10
4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 100 Ω system
Symmetrical
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

C1 / C2 / C3 / D1
14 V DC / 9.8 V AC
450 mA (45°C)
10 kA / 10 kA
20 kA
≤ 45 V (C3 - 25 A) / ≤ 45 V (C3 - 25 A)
Typ. 70 MHz
17.7 mm / 90 mm / 65.5 mm
-40 °C ... 85 °C
IP20
V0
IEC 61643-21/A1 / EN 61643-21/A1

Ordering data
Nominal voltage UN

Description

PLUGTRAB connector, with protective circuit for inserting in PT
base element
12 V DC
PLUGTRAB base element, for mounting on NS 35
Gas-filled surge arrester between 3/4 () and 9/10

Type

Order No.

Pcs. /
Pkt.

PT 5-HF-12 DC-ST

2838775

10

PT 2X2+F-BE

2839224

10

Accessories
Labeling material

118

PHOENIX CONTACT

ZBF ..., see page 111

Surge protection and interference filters
Surge protection for information technology and telecommunications
Surge protection for TTY interfaces

Notes:

H

For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

–
–
–
–
–

For floating signal circuits or signal cables
Low voltage limitation
Fast response
High discharge capacity
Connectors can be checked with
CHECKMASTER

W

D

Pin configuration PT 2x2-24DC...:
– 1/5 data line pair A
– 7/11 data line pair B
–3


Two double wires (loops), floating,
for 20 mA current loops

* Note:
Various grounding options for the base elements:
PT .x.-BE connections 9/10 (GND) directly connected to the mounting foot.
PT .x.+F-BE connection 9/10 (GND) connected to the mounting foot via a gas-filled
surge arrester.

Total width 17.7 mm
1

2

5

6

3

IN
9

4

*

OUT
10

7

8

11

12

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 50 Ω system
Symmetrical
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

C1 / C2 / C3 / D1
28 V DC / 20 V AC
450 mA (45°C)
10 kA / 10 kA
20 kA
≤ 50 V (C3 - 25 A) / Typ. 6 MHz
17.7 mm / 90 mm / 65.5 mm
-40 °C ... 85 °C
IP20
V0
IEC 61643-21 / DIN EN 61643-21 / UL 497B

Ordering data
Nominal voltage UN

Description

PLUGTRAB connector, with protective circuit for inserting in PT
base element
24 V DC
PLUGTRAB base element, for mounting on NS 35
Bridge between 3/4 () and 9/10
Gas-filled surge arrester between 3/4 () and 9/10

Type

Order No.

Pcs. /
Pkt.

PT 2X2-24DC-ST

2838228

10

PT 2X2-BE
PT 2X2+F-BE

2839208
2839224

10
10

2839295
2839512

10
10

Accessories
Shield fast connection
For Ø 3-6 mm
For Ø 5-10 mm

SSA 3-6
SSA 5-10

Labeling material

ZBF ..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

119

Surge protection and interference filters
Surge protection for information technology and telecommunications
Surge protection for RS-485
interfaces

Notes:

H

For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

–
–
–
–

PLUGTRAB PT 5-HF
High transmission speed
Fast response time
High discharge capacity
Connectors can be checked with
CHECKMASTER

PLUGTRAB PT-IQ 5-HF
– Surge protection system
– Collective message about supply and remote module
– Multi-level, floating remote signaling
– System supplied via DIN rail bus
– PT-IQ...-UT base element with screw connection technology
– PT-IQ...-PT base element with push-in
connection technology

Plug-in arrester with screw connection, for five
conductors, with common reference potential

Total width 17.7 mm

Pin assignment PT 5-HF...:
– 1,5 Data line pair 1T(A)/T(B)
– 7,11 Data line pair 2 R(A)/R(B)
–9
Signal ground (Ground)
–3

DATATRAB DT-UFB-485
– Adapter type
– 9-pos. D-SUB connection
– DIN rail mounting possible by removing
the cap
Pin assignment DT-UFB-485:
– 3,8 Data line pair 1 T(A)/T(B)
– 4,9 Data line pair 2 R(A)/R(B)
– 2,7 Signal ground (Ground)
– 
* Note:
Various grounding options for the base elements:
PT .x.-BE connections 9/10 (GND) directly connected to the mounting foot.
PT .x.+F-BE connection 9/10 (GND) connected to the mounting foot via a gas-filled
surge arrester.

W

D

1

2

5

6

7

8

11

12

OUT

IN

9

*

3

10
4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 100 Ω system
Symmetrical
In a 150 Ω system
Symmetrical
General data
Dimensions W / H / D
PT-IQ...UT dimensions W/H/D
PT-IQ...PT dimensions W/H/D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method

... 5DC
C1 / C2 / C3 / D1
5.2 V DC / 3.6 V AC
450 mA (45°C)

... 12DC
C1 / C2 / C3 / D1
14 V DC / 9.8 V AC
450 mA (45°C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

≤ 34 V (C3 - 25 A) / -

≤ 45 V (C3 - 25 A) /
≤ 45 V (C3 - 25 A)

Typ. 70 MHz
-

Typ. 70 MHz
-

17.7 mm / 90 mm / 65.5 mm
-40 °C ... 85 °C
IP20
V0
Screw connection (in connection with the base element)

Test standards

IEC 61643-21/A1 / EN 61643-21/A1

Ordering data
Description

Nominal voltage UN

PLUGTRAB connector, with protective circuit for inserting in PT
base element
5 V DC
12 V DC
PLUGTRAB base element, for mounting on NS 35
Bridge between 3/4 () and 9/10
Gas-filled surge arrester between 3/4 () and 9/10
MCR-PLUGTRAB, consisting of a plug, base element, and DIN rail
bus, with screw connection technology

Type

Order No.

Pcs. /
Pkt.

PT 5-HF- 5 DC-ST
PT 5-HF-12 DC-ST

2838762
2838775

10
10

PT 2X2-BE
PT 2X2+F-BE

2839208
2839224

10
10

Bridge between 3/4 () and 9/10
Bridge between 3/4 () and 9/10
MCR-PLUGTRAB, consisting of a plug, base element, and DIN rail
bus, with push-in connection technology
Bridge between 3/4 () and 9/10
Bridge between 3/4 () and 9/10
DATATRAB-Adapter, Protective adapter to be inserted in the data
line for the protection of the RS-485 interfaces

Accessories
Marking material

120

PHOENIX CONTACT

ZBF ..., see page 111

Surge protection and interference filters
Surge protection for information technology and telecommunications
H

H
W

D

5-wire with common reference potential,
9/10 connection grounded directly

H
W

D

5-wire with common reference potential,
9/10 connection grounded via gas-filled surge
arrester

Total width 17.7 mm

Total width 17.7 mm

2

1

2

5

6

5

6

7

8

7

8

protected

unprotected

3

3

8

8
2,7

2,7

IN
protected

11

12

11

12

9

10

9

10

3

4

3

4

Technical data

Protective adapter with 9-pos. D-SUB

Total width 25 mm

1

unprotected

W

D

OUT
4

4

9

9

Technical data

Technical data

... 5DC
C1 / C2 / C3 / D1
6 V DC / 4 V AC
600 mA (up to 40 °C)

... 12DC
C1 / C2 / C3 / D1
15 V DC / 10 V AC
600 mA (up to 40 °C)

... 5DC
C1 / C2 / C3 / D1
6 V DC / 4 V AC
600 mA (up to 40 °C)

... 12DC
C1 / C2 / C3 / D1
15 V DC / 10 V AC
600 mA (up to 40 °C)

B2 / C1 / C2 / C3 / D1
12 V DC / ≤ 380 mA (25°C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

≤ 5 kA / ≤ 5 kA
10 kA

≤ 30 V (C3 - 25 A) / -

≤ 40 V (C3 - 25 A) / -

≤ 30 V (C3 - 25 A) / -

≤ 40 V (C3 - 25 A) / -

≤ 30 V (C1 - 500 A) / ≤ 700 V (C1 - 500 A)

> 60 MHz

> 60 MHz

> 60 MHz

> 60 MHz

Typ. 50 MHz
-

17.7 mm / 91 mm / 77.5 mm
17.7 mm / 91 mm / 77.5 mm
17.7 mm / 109.3 mm / 77.5 mm
-40 °C ... 70 °C
IP20
V0
Screw connection / Push-in connection

17.7 mm / 91 mm / 77.5 mm
17.7 mm / 91 mm / 77.5 mm
17.7 mm / 109.3 mm / 77.5 mm
-40 °C ... 70 °C
IP20
V0
Screw connection / Push-in connection

EN 61643-21/A1 / IEC 61643-21/A2 / EN 61000-6-2/A1 /

EN 61643-21/A1 / IEC 61643-21/A2 / EN 61000-6-2/A1 /

Ordering data

Ordering data

Type

Order No.

PT-IQ-5-HF-5DC-UT
PT-IQ-5-HF-12DC-UT

2800797
2800799

PT-IQ-5-HF-5DC-PT
PT-IQ-5-HF-12DC-PT

2801291
2801293

Pcs. /
Pkt.

DIN EN 61643-21

Ordering data
Pcs. /
Pkt.

Type

Order No.

1
1

PT-IQ-5-HF+F-5DC-UT
PT-IQ-5-HF+F-12DC-UT

2800798
2800801

1
1

1
1

PT-IQ-5-HF+F-5DC-PT
PT-IQ-5-HF+F-12DC-PT

2801292
2801295

1
1

Accessories
ZBF ..., see page 111

25 mm / 110 mm / 63 mm
-40 °C ... 85 °C
IP20
D-SUB-9

Type

Order No.

DT-UFB-485/BS

2920612

Accessories

Pcs. /
Pkt.

1

Accessories

ZBF ..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

121

Surge protection and interference filters
Surge protection for information technology and telecommunications
Surge protection for the INTERBUS
remote bus

Notes:

H

For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

–
–
–
–
–
–
–
–
–

DATATRABDT-UFB-IB-RBI/ -RBO
Adapter type
9-pos. D-SUB connection
For remote bus modules
DIN rail mounting possible by removing
the cap
D-SUB cable included
PLUGTRAB PT 5-HF
High transmission speed
Fast response time
High discharge capacity
Connectors can be checked with
CHECKMASTER

W

D

Protective adapters for 5-wire remote bus
input

Total width 25 mm
I
7

7

* Note: PT .x.+F-BE connections 9/10
(GND) are linked to the mounting foot via
a gas-filled surge arrester.

I
2

2

3

3

IN

–
–
–
–
–

PLUGTRAB PT-IQ 5-HF
Surge protection system
Collective message about supply and remote module
Multi-level, floating remote signaling
System supplied via DIN rail bus
Base element with screw connection
technology

OUT
I
6

6
I

1

1

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 100 Ω system
Symmetrical
In a 150 Ω system
Symmetrical
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method

25 mm / 110 mm / 63 mm
-40 °C ... 85 °C
IP20
D-SUB-9

Test standards

DIN EN 61643-21 / IEC 61643-21

B2 / C1 / C2 / C3 / D1
5.8 V DC / ≤ 180 mA (25°C)
≤ 5 kA / ≤ 5 kA
10 kA
≤ 20 V (C1 - 500 A) / ≤ 700 V (C1 - 500 A)
≥ 100 MHz
≥ 100 MHz

Ordering data
Description

Nominal voltage UN

Type

Order No.

DT-UFB-IB-RBI

2800055

Pcs. /
Pkt.

PLUGTRAB connector, with protective circuit for inserting in PT
base element
5 V DC
PLUGTRAB base element, for mounting on NS 35
Gas-filled surge arrester between 3/4 () and 9/10
DATATRAB adapter, protective adapters for inserting into the
data line
MCR-PLUGTRAB, consisting of a plug, base element, and DIN rail
bus
Gas-filled surge arrester between 3/4 () and 9/10
TERMITRAB, modular terminal block with integrated surge protection, for mounting on NS 35

122

PHOENIX CONTACT

1

Surge protection and interference filters
Surge protection for information technology and telecommunications
H

H
W

D

H
W

D

Protective adapters for 5-wire remote
bus output

Total width 25 mm

Plug-in arrester with screw connection, for five
conductors, with common reference potential

Total width 17.7 mm

Total width 17.7 mm

7
I

2

2

3

3

IN

OUT

1

2

5

6

7

8

OUT

IN
11

I

9

I
1

1

3

Technical data

*

1

2

5

6

7

8

11

12

9

10

3

4

unprotected

12

6

6

W

Plug-in arrester with screw connection, for five
conductors, with common reference potential

I
7

D

10
4

protected

Technical data

Technical data

B2 / C1 / C2 / C3 / D1
5.8 V DC / ≤ 180 mA (25°C)

C1 / C2 / C3 / D1
5.2 V DC / 3.6 V AC
450 mA (45°C)

C1 / C2 / C3 / D1
6 V DC / 4 V AC
600 mA (up to 40 °C)

≤ 5 kA / ≤ 5 kA
10 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

≤ 20 V (C1 - 500 A) / ≤ 700 V (C1 - 500 A)

≤ 34 V (C3 - 25 A) / ≤ 34 V (C3 - 25 A)

≤ 30 V (C3 - 25 A) / ≤ 900 V (C3 - 25 A)

≥ 100 MHz
≥ 100 MHz

Typ. 70 MHz
-

> 60 MHz

25 mm / 110 mm / 63 mm
-40 °C ... 85 °C
IP20
D-SUB-9

17.7 mm / 90 mm / 65.5 mm
-40 °C ... 85 °C
IP20
V0
Screw connection (in connection with the base element)

17.7 mm / 91 mm / 77.5 mm
-40 °C ... 70 °C
IP20
V0
Screw connection

DIN EN 61643-21 / IEC 61643-21

IEC 61643-21/A1 / EN 61643-21/A1

EN 61643-21/A1 / IEC 61643-21/A2 / EN 61000-6-2/A1 /

Ordering data
Type

DT-UFB-IB-RB0

Ordering data
Order No.

2800056

Pcs. /
Pkt.

Ordering data

Type

Order No.

Pcs. /
Pkt.

PT 5-HF- 5 DC-ST

2838762

10

PT 2X2+F-BE

2839224

10

Type

Order No.

PT-IQ-5-HF+F-5DC-UT

2800798

Pcs. /
Pkt.

1

TT-SLKK5-F/110AC

2765602

1

50

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

123

Surge protection and interference filters
Surge protection for information technology and telecommunications
Surge protection for PROFIBUS

Notes:

H

For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

–
–
–
–
–

PT 3-PB
Protection for two signal wires with common reference potential
Data transmission rate up to 12 Mbps
For INTERBUS/PROFIBUS systems
For field multiplexers
Connectors can be checked with
CHECKMASTER

Pin assignment PT 3-PB:
– 7,11 data cable pair
–9
Signal ground (Ground)

W

D

Plug-in arrester with screw connection, for five
conductors, with common reference potential

D-UFB-PB
– Direct use at the interface
– Data transmission rate up to 12 Mbps
– Integrated termination resistor

Total width 17.7 mm

* Note: PT .x.-BE connections 9/10
(GND) are linked directly to the mounting
foot.

7

8

11

12

9

10

OUT

IN

*

3

4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core / Core-Ground

C1 / C2 / C3 / D1
5.2 V DC / 3.6 V AC
450 mA (45°C)
10 kA / 10 kA
20 kA
≤ 34 V (C3 - 25 A) / ≤ 34 V (C3 - 25 A)

Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 100 Ω system
Symmetrical
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method

≤ 15 V / ≤ 15 V

17.7 mm / 90 mm / 65.5 mm
-40 °C ... 85 °C
IP20
V0
Screw connection (in connection with the base element)

Test standards

IEC 61643-21/A1 / EN 61643-21/A1

Typ. 70 MHz

Ordering data
Description

Nominal voltage UN

PLUGTRAB connector, with protective circuit for inserting in PT
base element
5 V DC
PLUGTRAB base element, for mounting on NS 35
Bridge between 3/4 () and 9/10
DATATRAB, Protective device for PROFIBUS-DP applications
with up to 12 Mbps

Type

Order No.

Pcs. /
Pkt.

PT 3-PB-ST

2858030

10

PT 1X2-BE

2856113

10

2839295
2839512

10
10

Accessories

124

PHOENIX CONTACT

Shield fast connection
For Ø 3-6 mm
For Ø 5-10 mm

SSA 3-6
SSA 5-10

Labeling material

ZBF ..., see page 111

Surge protection and interference filters
Surge protection for information technology and telecommunications

Fine protection with 9-pos. D-SUB

Total width 44.5 mm

IN

OUT
2B

6 VP

2A

5 GND

1B

3 D(P)

1A

8 D(N)

Technical data
C1 / C3 / B2
5.2 V DC / 250 mA (25°C)
350 A / 350 A
350 A
≤ 25 V (C1 (500 V/250 A)) / ≤ 25 V (C1 (500 V/250 A))

≤ 14 V / ≤ 14 V
Typ. 70 MHz
44.5 mm / 58 mm / 16.6 mm
-20 °C ... 75 °C
IP40
Screw connection & D-SUB-9
IEC 61643-21

Ordering data
Type

Order No.

D-UFB-PB

2880642

Pcs. /
Pkt.

1

Accessories

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

125

Surge protection and interference filters
Surge protection for information technology and telecommunications
For power supply and ISDN-S0
interface

Notes:
For certifications, see page 154

MNT-ISDN
– Compact protection for termination devices
– Easy operation
– Combined power supply and ISDN
protection
– Connection to telecommunications
socket using separate cable
– Thermal monitoring of the protective
circuit
– Green LED - operating indicator for the
power supply

For network and ISDN/RDSI systems/termination devices, with RJ45 connection

DT-LAN-CAT.6+
– Protective adapter for eight signal paths
via RJ45 connector
– Can be installed in a control cabinet by
removing a ground connection adapter

Total width 63 mm

WT-RJ 45-S/ISDN 1/K AP
– Surface-mounted socket
– With RJ45 socket as IAE
– Optimum in-house protection for sensitive interfaces

5

4

6

3 PE

5

4

6

3

N

L

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Combined surge UOC
Protection level UP
Core-Core / Core-Ground

Mains protection
III / T3
230 V AC
360 V AC (L/N-PE)
16 A (30 °C)

Data protection
C2 / C3 / D1 / C1
6 V DC
1.5 A (25°C)

3 kA / 3 kA
4 kV

650 A / 2.5 kA
-

≤ 1.2 kV / ≤ 1.5 kV

Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs

-

≤ 65 V (C1 - 1 kV/500 A) / ≤ 900
V (C2 - 4 kV/2 kA)
10 kA

Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 100 Ω system
Core-Core
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method
Test standards

-

≤ 10 V / ≤ 900 V

-

Typ. 300 kHz

IEC 61643-1

63 mm / 79 mm / 103.5 mm
-25 °C ... 75 °C
IP20 (child-proof)
V0/HB
RJ45
IEC 61643-21

Ordering data
Description

Can be used as typical for
the country

Type

Order No.

MNT-ISDN D
MNT-ISDN D/WH
MNT-ISDN S/WH

2882336
2882349
2880891

Pcs. /
Pkt.

MAINTRAB, surge protection attachment plug for plugging into a
socket for equipment and data interface protection, incl. 1.5 m
coaxial cable.
Black
D, A, NL
White
D, A, NL
White
S, FIN, N
DATATRAB adapter, protective adapters for inserting into the
data line
WESTERNTRAB, RJ45 outlet box, surface-type with surge protection for ISDN So bus interface

Accessories
Patch cable, CAT6, pre-assembled

126

PHOENIX CONTACT

1
1
1

Surge protection and interference filters
Surge protection for information technology and telecommunications
H
W

D

For LAN interfaces (Class EA/CAT 6) including
PoE and ISDN S0 protection

Surface-mounted flush-type socket with RJ45
connection

Total width 25 mm

Total width 65 mm

1

2

6 OUT 4

3

5

7

8

IN

1

2

3

6 IN 4

5

7

3

3

6

6

4

4

5

5

OUT

PE

8

Technical data

Technical data

B2 / C1 / C2 / C3 / D1
≤ 3.3 V DC (± 60 V DC/PoE+)
≤ 1.5 A (25°C)

C2 / C3 / D1
50 V DC (S0 phantom power supply)
6.2 V DC
1.5 A (25°C)

100 A / 2 kA (per signal pair)
-

350 A / 5 kA
-

≤ 9 V (B2 - 1 kV/25 A) / ≤ 700 V (C2 - 4 kV/2 kA)

≤ 70 V (C1 - 1 kV/500 A) / ≤ 460 V (C1 - 1 kV/500 A)

10 kA

10 kA

≤ 9 V / ≤ 700 V

≤ 12 V / ≤ 460 V

> 500 MHz

Typ. 80 MHz

25 mm / 103 mm / 63 mm
-40 °C ... 70 °C
IP20
RJ45
IEC 61643-21

65 mm / 30 mm / 80 mm
-40 °C ... 60 °C
IP20
Screw connection & RJ45
IEC 61643-21

Ordering data

Ordering data

Type

Order No.

DT-LAN-CAT.6+

2881007

Pcs. /
Pkt.

Type

Order No.

1

WT-RJ 45-S/ISDN1/K AP

Accessories
FL CAT6 PATCH 1,5

Pcs. /
Pkt.

2809830

1

Accessories
2891482

10

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

127

Surge protection and interference filters
Surge protection for information technology and telecommunications
Surge protection for the ISDN-S0
interface

Notes:
For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

COMTRAB modular
– Plug-in module
– Can be used in LSA-PLUS disconnect and
control strips or CT-TERMIBLOCK
– High transmission bandwidth
– Use of two CTM ISDN for one ISDN
connection
– Connectors can be checked with
CHECKMASTER
For a double wire

Total width 9.5 mm
1'

1

OUT

IN

2

2'

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core / Core-Ground

B2 / C2 / C3 / D1 / C1
± 6 V DC
1.5 A (25 °C)
350 A / 5 kA
10 kA
≤ 35 V (C1, 700 V/350 A) / ≤ 700 V (C3, 7.5 kV/100 A, spike)

Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 100 Ω system
Symmetrical
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method
Test standards

≤ 15 V / ≤ 700 V
≥ 100 MHz
9.5 mm / 21 mm / 53.5 mm
-25 °C ... 75 °C
IP20
V0
can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
IEC 61643-21

Ordering data
Description

Order No.

Pcs. /
Pkt.

2838555

10

CTM 10-MAG

2838610

5

CT-TERMIBLOCK 10 DA

0441711

10

Type

COMTRAB modular, surge protection for the ISDN S0 interface
CTM ISDN

Accessories
Magazine, with grounding rail for accommodating up to
10 LSA-PLUS protective connectors (CTM...), for insertion in
CT-TERMIBLOCK or LSA-PLUS disconnect strip

Screw terminal block, with disconnect contacts for
accommodating the CT and CTM protective connectors,
design: 10 double wires

128

PHOENIX CONTACT

Surge protection and interference filters
Surge protection for information technology and telecommunications
Surge protection for ISDN-Uk0
interfaces and T1/DS1 systems
PT 2-TELE
– For ISDN Uk0 and DSL applications
– Broadband protection for telecommunications lines
– Connection: 7.11 for a/b wire pair
D-DS1-A/RJ45-BB
– For applications with T1 (DS1) or E1 data
transmission protocol
– Connection via a keyed RJ45 (RJ48) female connector
– High transmission bandwidth

H
W

D

Plug-in arrester with screw connection,
for three conductors, with common reference
potential

RJ45 attachment plug for two double wires

Notes:
For certifications, see page 154

Total width 17.7 mm

Attenuation characteristics at www.phoenixcontact.net/products

Total width 25.4 mm
8

7

1

1

2

2

4

4

5

5

J
J

IN

11

12

9

10

3

4

OUT

IN

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Core / Core-Ground

OUT

Technical data

C1 / C2 / C3 / D1 / B2
185 V DC / 130 V AC
450 mA (45°C)

C2 / C3 / D1
7 V DC / 1.5 A (25°C)

10 kA / 10 kA
20 kA

350 A / 2.5 kA
10 kA

≤ 270 V (C1 - 1 kV/500 A) / ≤ 300 V (C2 - 2 kV / 1 kA)

≤ 50 V / ≤ 600 V

≤ 300 V / ≤ 300 V

≤ 20 V / ≤ 450 V

Typ. 20 MHz

≥ 100 MHz

17.7 mm / 90 mm / 65.5 mm
-40 °C ... 85 °C
IP20
V0
Screw connection
0.2 mm² - 4 mm² / 0.2 mm² - 2.5 mm² / 24 - 12
IEC 61643-21 / DIN EN 61643-21

25.4 mm / 25.4 mm / 102 mm
-40 °C ... 80 °C
IP20
RJ45
IEC 61643-21

Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 100 Ω system
Symmetrical
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method
Connection data solid / stranded / AWG
Test standards

Ordering data
Description

Type

Ordering data
Order No.

Pcs. /
Pkt.

2882828

10

Type

Order No.

Pcs. /
Pkt.

DATA-PLUGTRAB,
consisting of plug and base element
PT 2-TELE
DATATRAB, attachment connector with surge protection for T1/E1
systems.
D-DS1-A/RJ45-BB

Accessories

2838050

1

2891385

10

Accessories

Replacement plug
PT 2-TELE-ST

2838733

10

Patch cable, CAT6, pre-assembled
FL CAT6 PATCH 1,0
Labeling material

ZBF ..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

129

Surge protection and interference filters
Surge protection for information technology and telecommunications
For analog and DSL telecommunications systems

Notes:
For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

–
–
–
–
–
–

MNT ...
Compact protection for termination devices
Easy operation
Thermal monitoring of the protective
circuit
Green LED - operating indicator for the
power supply
MNT-TAE, with TAE connection for DSL
(ADSL2+) and in the ISDN network before the NTBA
MNT-TELE, with RJ12/RJ45 sockets, for
telephone, modem, and answering machine with a max. operating voltage of
185 V

16.000

For telecommunications systems with TAE
connection

Total width 63 mm

TAE-TRAB FM-NFN
– For surface mounting
– Three TAE6 slots
– For two N-encoded and one F-encoded
termination device
– Suitable for DSL (ADSL2+)
– Main areas of application: phone terminals, answering machines, modems, and
fax machines
–
–
–
–

WT-RJ12
Surface-mounted socket
With 6-pos. RJ12 Western socket
Also accommodates RJ11 plug
Angled RJ12 take-up

3/5

2/4

2

1

PE

N

L

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Combined surge UOC
Protection level UP
Core-Core / Core-Ground

Mains protection
III / T3
230 V AC
360 V AC (L/N-PE)
16 A (30 °C)

Data protection
C1 / C2 / C3 / D1
200 V DC
1.5 A (25°C)

3 kA / 3 kA
4 kV

1 kA / 2.5 kA
-

≤ 1.2 kV / ≤ 1.5 kV

Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs

-

≤ 460 V (C2 - 1 kA) / ≤ 900 V (C2
- 2 kA)
5 kA

Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 600 Ω system
Core-Core
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method
Test standards

-/-

≤ 360 V / -

-

-

IEC 61643-1

63 mm / 79 mm / 103.5 mm
-25 °C ... 75 °C
IP20 (child-proof)
V0/HB
RJ12/TAE 6
IEC 61643-21

Ordering data
Description

Can be used as typical for
the country

Type

Order No.

MNT-TAE D
MNT-TAE D/WH

2882381
2882394

Pcs. /
Pkt.

MAINTRAB, combination surge protection adapter for plugging
into a socket, for equipment and TAE protection
Black
D
White
D
TAE outlet box (NFN) with surge protection for analog telecommunications interfaces
Surface-mounted socket
D
MAINTRAB, combined surge protection adapter for plugging into a
socket, for device and TEL/TELE protection.
Black
B, F, CZ, SVK, PL
Black
E, P, I, NL, LUX
White
S, FIN
White
N
WESTERNTRAB, RJ12 connection socket with surge protection
for analog telecommunication interfaces
Surface-mounted socket, 1 socket

130

PHOENIX CONTACT

1
1

Surge protection and interference filters
Surge protection for information technology and telecommunications

16.000

16.000

TAE outlet box (NFN)

For telecommunications systems with
RJ12/RJ45 connection

Total width 65 mm

Surface-mounted socket with RJ12
connection

Total width 63 mm

3

a2
4
3

b2

5
2

6
1

4

2

Total width 65 mm

5 PE

N

L

N

E
4
3

W

5
2

6
1

F

Lb
4
3

La

5
2

6
1

N

Technical data

a1

2

a2

5

La

3

Lb

4

b1

1

b2

6

Technical data

Technical data

B2 / C1 / C2 / C3 / D1
60 V DC
185 V DC
450 mA (≤ 40°C)

Mains protection
III / T3
230 V AC
360 V AC (L/N-PE)
16 A (30 °C)

Data protection
C1 / C2 / C3 / D1
200 V DC
1.5 A (25°C)

C1 / C2 / C3 / D1
185 V DC
150 mA (25°C)

5 kA / 5 kA
-

3 kA / 3 kA
4 kV

1 kA / 2.5 kA
-

2.5 kA / 2.5 kA
-

≤ 250 V (C2 - 10 kV / 5 kA) / ≤ 500 V (C2 - 10 kV / 5 kA)

≤ 1.2 kV / ≤ 1.5 kV

≤ 240 V / ≤ 700 V

10 kA

-

≤ 460 V (C2 - 1 kA) / ≤ 900 V (C2
- 2 kA)
10 kA

10 kA

≤ 250 V / ≤ 450 V

-/-

≤ 360 V / -

≤ 220 V / ≤ 700 V

Typ. 2 MHz

-

-

Typ. 1.7 MHz

65 mm / 27 mm / 80 mm
-40 °C ... 80 °C
IP20
Screw connection & TAE 6
DIN EN 61643-21

63 mm / 79 mm / 103.5 mm
-25 °C ... 75 °C
IP20 (child-proof)
V0/HB
RJ12
EN 61643-11/A11
EN 61643-11/A11

Ordering data

65 mm / 39 mm / 80 mm
-40 °C ... 80 °C
IP20
Screw connection & RJ12
IEC 61643-21

Ordering data

Type

Order No.

TAE-TRAB FM-NFN-AP

2749628

Pcs. /
Pkt.

Ordering data

Type

Order No.

MNT-TEL B/F
MNT-TELE E
MNT-TELE S/WH
MNT-TELE N/WH

2882404
2882417
2880901
2881764

Pcs. /
Pkt.

Type

Order No.

WT-RJ 12-S/FM A/K AP

2809186

Pcs. /
Pkt.

1

1
1
1
1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1

131

Surge protection and interference filters
Surge protection for information technology and telecommunications
Surge protection for analog and DSL
telecommunication systems

Notes:

Attenuation characteristics at www.phoenixcontact.net/products

–
–
–
–
–

PT 2-TELE
For analog telecommunications
Two-piece, plug-in
Universal use
High discharge capacity
Connectors can be checked with
CHECKMASTER

DT-TELE-RJ45
– For analog and digital (DSL) telecommunications interface
– Connection: RJ45 socket and/or plug-in
screw terminal blocks
– The adapter included enables conversion
from RJ45 to RJ11 and RJ12 (for contacting, see circuit diagram)
– International use thanks to multiple assignment
– DIN rail mounting possible by removing
the cap
–
–
–
–

CTM
For analog telecommunications
Plug-in module
Can be used in LSA-PLUS disconnect/control strips or CT-TERMIBLOCK
Connectors can be checked with
CHECKMASTER

H

For certifications, see page 154

W

D

Plug-in arrester with screw connection,
for three conductors, with common reference
potential

Total width 17.7 mm
8

7

J
J

IN

11

12

9

10

3

4

OUT

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Core / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Core / Core-Ground
Cut-off frequency fg (3 dB)
In a 100 Ω system
Symmetrical / Asymmetrical
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method

17.7 mm / 90 mm / 65.5 mm
-40 °C ... 85 °C
IP20
V0
Screw connection

Connection data solid / stranded / AWG
Test standards

0.2 mm² - 4 mm² / 0.2 mm² - 2.5 mm² / 24 - 12
IEC 61643-21 / DIN EN 61643-21

C1 / C2 / C3 / D1 / B2
185 V DC / 130 V AC
450 mA (45°C)
10 kA / 10 kA
20 kA
≤ 300 V / ≤ 300 V
Typ. 20 MHz / -

Ordering data
Description

Type

Order No.

Pcs. /
Pkt.

PT 2-TELE

2882828

10

2838733

10

DATA-PLUGTRAB,
consisting of plug and base element
DATATRAB, surge protection for two signal pairs of the analog and
digital (DSL) telecommunication interface

COMTRAB modular

Accessories
Replacement connector
PT 2-TELE-ST
Magazine, with grounding rail for accommodating up to
10 LSA-PLUS protective connectors (CTM...), for insertion in
CT-TERMIBLOCK or LSA-PLUS disconnect strip

Screw terminal block, with disconnect contacts for
accommodating the CT and CTM protective connectors,
design: 10 double wires
Labeling material

132

PHOENIX CONTACT

ZBF ..., see page 111

Surge protection and interference filters
Surge protection for information technology and telecommunications

16.000

16.000

16.000

RJ45 attachment plug for two double wires

RJ 11

RJ 12

RJ 45

3

4

2

3

4 a1

Plug

RJ 45

a1 2

Plug

RJ 12

Total width 9.5 mm

RJ 11

Total width 25 mm

2-wire coarse protection, with failsafe contact

Double wire (loop), floating

Total width 9.5 mm
1'

1

1'

1



b1 3

4

J

5

3

4

5 b1

IN
a2 1

OUT

IN

OUT
2 3

1

2

3 a2

4

5

6 b2

IN

OUT

J



b2 4

5

2

6

Technical data

2'

2

Technical data

2'

Technical data

B2 / C1 / C2 / C3 / D1
185 V DC / 130 V AC
≤ 380 mA (25°C)

A2 / B1 / B2 / B3 / C1 / C2 / C3 / D1 / D2
± 180 V DC / 1.5 A (25°C)

B2 / C1 / C2 / C3 / D1
± 180 V DC / 380 mA (25°C)

≤ 5 kA / ≤ 5 kA
10 kA

- / 5 kA
10 kA

5 kA / 5 kA
10 kA

≤ 250 V / ≤ 250 V

- / ≤ 800 V

≤ 260 V / ≤ 800 V

Typ. 50 MHz / -

- / > 100 MHz

20 MHz / -

25 mm / 103 mm / 63 mm
-40 °C ... 85 °C
IP20
RJ45 / Combicon

9.5 mm / 21 mm / 53.5 mm
-40 °C ... 85 °C
IP20
V0
can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
IEC 61643-21

9.5 mm / 21 mm / 53.5 mm
-25 °C ... 75 °C
IP20
V0
can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
IEC 61643-21

Ordering data

Ordering data

IEC 61643-21

Ordering data
Type

Order No.

DT-TELE-RJ45

2882925

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

2838636

10

Order No.

Pcs. /
Pkt.

2838539

10

CTM 10-MAG

2838610

5

CT-TERMIBLOCK 10 DA

0441711

10

Type

1
CTM 2X1-180DC-GS

Accessories

CTM 1X2-110AC

Accessories

Accessories

CTM 10-MAG

2838610

5

CT-TERMIBLOCK 10 DA

0441711

10

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

133

Surge protection and interference filters
Surge protection for transceiver systems

You won't lose reception with COAXTRAB
Transceiver systems are generally considered to be particularly susceptible to surge
voltages. Antenna cables which extend beyond a building and are usually very long,
plus the antennas themselves, are directly
exposed to atmospherical discharge.

134

PHOENIX CONTACT

Cables with a coaxial structure and therefore favorable EMC properties are primarily
used in antenna systems. However, the risk
of surge voltage coupling in antenna cables
and potential transfer through to the sensitive interfaces of transceiver systems is not
eliminated.

Thanks to interface-optimized surge protective devices, the COAXTRAB product
range significantly increases safety for transceiver equipment. The aim of such safety
measures is to increase the availability and
operability of the devices affected.

Surge protection and interference filters
Surge protection for transceiver systems

Shielding
Good shielding properties are vital for a
clean transmission. The rugged metal housings provide ideal shielding properties and
are also suitable for use in harsh industrial
environments.

Customized products
Appropriate protective devices are available for all applications including SAT receiver systems, mobile phones, and video monitoring.
The very low attenuation values ensure
that data transmission is clean.

Performance classes
The protective devices conform to standards in all performance classes. This applies
for coarse protection in accordance with
Category D1, 10/350 μs and for fine protection in accordance with Category C1,
8/20 μs.

Connection technology
The right connection technology to suit
the application: F connector, TV connector,
type N, 7/16, UHF, BNC, SMA.

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

135

Surge protection and interference filters
Surge protection for transceiver systems
Protective adapters with coaxial
connection
COAXTRAB
– For antennas with N and BNC
connection
– High transmission capacities even for frequencies up to 6 GHz
– Mounting plate enables fixed mounting,
e.g., in a control cabinet
– The protective adapters can also be used
in a 75 Ω system with 50 Ω BNC connectors

Notes:
For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

For GSM systems (3 GHz), grounded shield,
connection: N type

Total width 31 mm

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Shield / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Shield / Core-Ground
Frequency range
Standing wave ratio SWR in a 50 Ω system
Permissible. RF power Pmax
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Connection method
Test standards

C2 / C3 / D1
280 V DC / 5 A (25°C)
20 kA / 20 kA
20 kA
≤ 900 V (C1 - 1 kV/500 A) / ≤ 900 V (C1 - 1 kV/500 A)
0 Hz ... 3 GHz
Typ. 1.15 (≤ 3 GHz)
700 W (VSWR = 1.1)
31 mm / 57.8 mm / 33.5 mm
-40 °C ... 80 °C
IP55
N connector 50 Ω
IEC 61643-21/A1 / EN 61643-21/A1

Ordering data
Description

Pcs. /
Pkt.

Type

Order No.

CN-UB-280DC-3-BB
CN-UB-280DC-3-SB

2801050
2801051

1
1

2818135
2803137

10
1

COAXTRAB, protective adapter for antenna connections
Female/female
Male/female

Accessories
Mounting plate, for individual attachment to housing panels
straight
angled
BNC connector, single-level, for mounting on NS 32 or NS 35/7.5
50 Ω wave impedance
Adapter, insertion loss <0.3 dB at 2.4 GHz
N (male) -> SMA (female)
Adapter cable, pigtail, insertion loss 1.5 dB at 2.4 GHz; impedance 50 Ω;
50 cm long, MCX (male) -> N (male)

136

PHOENIX CONTACT

CN-UB/MP
CN-UB/MP-90DEG-50

Surge protection and interference filters
Surge protection for transceiver systems

With N connector (0 - 6 GHz), grounded shield

Total width 24 mm

With N connector, floating shield

With BNC connector, floating shield

Total width 25.4 mm

Technical data

Total width 25.4 mm

Technical data

Technical data

C2 / C3 / D1
70 V DC / 50 V AC
10 A

C2 / C3 / D1
180 V DC / 130 V AC
5 A (25°C)

C2 / C3 / D1
180 V DC / 130 V AC
3.5 A (25°C)

5 kA / 5 kA
5 kA

5 kA / 5 kA
10 kA

5 kA / 5 kA
10 kA

- / ≤ 800 V (C2 (4 kV/2 kA))

- / ≤ 500 V (C2, 10 kV/5 kA)

- / ≤ 500 V (C2 - 10 kV / 5 kA)

0 Hz ... 6 GHz
Typ. 1.15 (6 GHz)
30 W (VSWR = 1.15)

≤ 1.2 (≤ 200 MHz)
300 W (VSWR = 1.1)

Typ. 1.3 (≤ 150 MHz)
300 W (VSWR = 1.1)

24 mm / 24 mm / 50 mm
-40 °C ... 90 °C
IP68
N connector 50 Ω
IEC 61643-21

25.4 mm / 83 mm / 25.4 mm
-40 °C ... 80 °C
IP20
N connector 50 Ω
-

25.4 mm / 2.54 mm / 80 mm
-40 °C ... 80 °C
IP20
BNC 50 Ω
IEC 61643-21 / DIN EN 61643-21

Ordering data

Ordering data

Type

Order No.

CN-UB-70DC-6-BB
CN-UB-70DC-6-SB

2803166
2803153

Pcs. /
Pkt.

1
1

Type

Order No.

CN-UB/E-BB
CN-UB/E

2817686
2763691

Accessories

CN-UB/MP
CN-UB/MP-90DEG-50

Ordering data
Pcs. /
Pkt.

1
1

Type

Order No.

Pcs. /
Pkt.

C-UB/E

2763701

10

2805041

10

Accessories

2818135
2803137

Accessories

10
1

BNC-V 50

RAD-ADP-N/M-SMA/F

2917036

1

RAD-PIG-EF316-MCX-N

2867681

1

2805041

10

BNC-V 50

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

137

Surge protection and interference filters
Surge protection for transceiver systems
Protection for mobile phone antennas

– For antennas with N, 7/16, and SMA connection
– High transmission capacities even for frequencies up to 6 GHz
– Maintenance-free surge protection with
Lambda/4 technology
– Low protection level
Notes:
For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

For TETRA systems (380 MHz - 470 MHz),
grounded shield

Total width 32 mm

Electrical data
IEC category / EN type
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Shield / Core-Ground
Total surge current (8/20) µs
Protection level UP
Core-Shield / Core-Ground
Frequency range
Standing wave ratio SWR in a 50 Ω system
Permissible. RF power Pmax
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Connection method
Test standards

For GSM systems (0.8 GHz-2.25 GHz),
grounded shield, connection: N type

Total width 25 mm

λ/4

λ/4

Technical data

Technical data

C2 / C3 / D1
5 A (25 °C)

C2 / C3 / D1
5 A (25 °C)

20 kA / 20 kA
30 kA

50 kA / 50 kA
60 kA

≤ 95 V (C2 - 10 kV / 5 kA) / ≤ 95 V (C2 - 10 kV / 5 kA)

- / ≤ 5 V (C1 - 1 kV/500 A)

380 MHz ... 470 MHz
Typ. 1.05 (≤ 1,15)
≤ 800 W

0.8 GHz ... 2.25 GHz
Typ. 1.2
≤ 500 W

32 mm / 32 mm / 83 mm
-40 °C ... 90 °C
IP68
N connector
IEC 61643-21

25 mm / 78.7 mm / 77.5 mm
-40 °C ... 85 °C
IP68
N connector 50 Ω
IEC 61643-21/A1 / EN 61643-21/A1

Ordering data

Ordering data

Description

Type

Order No.

COAXTRAB, protective adapter for antenna connections with
Lambda/4 technology
Female/female
Male/female
Surge protection for UMTS and quad-band GSM antenna, with
SMA connector and SMA coupling

CN-LAMBDA/4-0.47-BB
CN-LAMBDA/4-0.47-SB

2800021
2800022

Pcs. /
Pkt.

1
1

Pcs. /
Pkt.

Type

Order No.

CN-LAMBDA/4-2.25-BB
CN-LAMBDA/4-2.25-SB

2801057
2801056

1
1

2818135
2803137

10
1

Accessories

Accessories

Mounting plate, for individual attachment to housing panels
straight
angled
Adapter, insertion loss <0.3 dB at 2.4 GHz
N (male) -> SMA (female)
Adapter cable, pigtail, insertion loss 1.5 dB at 2.4 GHz; impedance 50 Ω;
50 cm long, MCX (male) -> N (male)

138

PHOENIX CONTACT

CN-UB/MP-90DEG-50

2803137

1

RAD-ADP-N/M-SMA/F

2917036

1

RAD-PIG-EF316-MCX-N

2867681

1

CN-UB/MP
CN-UB/MP-90DEG-50

Surge protection and interference filters
Surge protection for transceiver systems

For GSM systems (0.8 GHz-2.25 GHz),
grounded shield, connection: 7/16

Protective adapter set with SMA connection,
grounded shield

Total width 39 mm

Total width 46.5 mm

For GSM and WiMAX systems
(2.4 GHz - 5.9 GHz), grounded shield

Total width 26.1 mm

λ/4

λ/4

λ/4

Technical data

Technical data

Technical data

C2 / C3 / D1
5 A (25 °C)

C2 / C3 / D1
2 A (25°C)

C2 / C3 / D1
5 A (25°C)

50 kA / 50 kA
60 kA

6 kA / 6 kA
6 kA

50 kA / 50 kA
60 kA

- / ≤ 5 V (C1 - 1 kV/500 A)

- / ≤ 5 V (C1 (1 kV/500 A))

- / ≤ 11 V (6 kV/3 kA)

0.8 GHz ... 2.25 GHz
Typ. 1.2
≤ 500 W

0.8 GHz ... 2.25 GHz
≤ 1.2 (0.8 GHz ... 2.25 GHz)
≤ 110 W (VSWR = 1.0)

2.4 GHz ... 5.9 GHz
Typ. 1.1 (≤ 1.20 (2.4 GHz...5.9 GHz))
≤ 500 W

39 mm / 83.5 mm / 82 mm
-40 °C ... 85 °C
IP68
7/16 connector
IEC 61643-21/A1 / EN 61643-21/A1

46.5 mm / 25 mm / 70 mm
-40 °C ... 70 °C
IP55
SMA connector
IEC 61643-21/A1 / EN 61643-21/A1

26.1 mm / 38 mm / 60 mm
-40 °C ... 90 °C
IP68
N connector
IEC 61643-21

Ordering data

Ordering data

Type

Order No.

C7/16-LAMBDA/4-2.25-BB
C7/16-LAMBDA/4-2.25-SB

2801060
2801059

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

1
1

CSMA-LAMBDA/4-2.0-BS-SET

Accessories

CN-UB/MP
CN-UB/MP-90DEG-50

Ordering data

2800491

Order No.

CN-LAMBDA/4-5.9-BB
CN-LAMBDA/4-5.9-SB

2838490
2800023

1
1

CN-UB/MP-90DEG-50

2803137

1

RAD-ADP-N/M-SMA/F

2917036

1

RAD-PIG-EF316-MCX-N

2867681

1

1

Accessories

2818135
2803137

10
1

CN-UB/MP
CN-UB/MP-90DEG-50

Pcs. /
Pkt.

Type

Accessories

2818135
2803137

10
1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

139

Surge protection and interference filters
Surge protection for transceiver systems
Protective adapters with BNC connection
COAXTRAB
– For insertion in the cable
– Ground connection via separately led
cable
Notes:
For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

For floating communication systems

For non-floating communication systems

Total width 25.4 mm

Total width 25.4 mm

OUT

IN

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Shield / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Shield / Core-Ground
Cut-off frequency fg (3 dB)
In a 50 Ω system
Asymmetrical
General data
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Connection method
Test standards

Technical data

... 5DC/E
C2 / C3 / D1
5 V DC
185 mA (25°C)

... 24DC/E
C2 / C3 / D1
30 V DC
185 mA (25°C)

... 5DC/E 75
C2 / C3 / D1
5 V DC
-

... 5DC
C2 / C3 / D1
5 V DC
185 mA (25°C)

... 24DC
C2 / C3 / D1
30 V DC
185 mA (25°C)

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
20 kA

10 kA / 10 kA
10 kA

10 kA / 10 kA
10 kA

≤ 15 V / -

≤ 45 V / -

≤ 15 V / -

≤ 15 V / ≤ 15 V

≤ 45 V / ≤ 45 V

Typ. 90 MHz

Typ. 90 MHz

Typ. 80 MHz

Typ. 90 MHz

Typ. 90 MHz

BNC 50 Ω

-40 °C ... 80 °C
IP20
BNC 50 Ω
BNC 75 Ω
IEC 61643-21

BNC 50 Ω

Ordering data
Description

OUT

IN

-40 °C ... 80 °C
IP20
BNC 50 Ω
IEC 61643-21

Ordering data

Type

Order No.

Pcs. /
Pkt.

C-UFB- 5DC/E
C-UFB-24DC/E
C-UFB- 5DC/E 75

2782300
2782313
2763604

10
10
10

Type

Order No.

Pcs. /
Pkt.

C-UFB- 5DC
C-UFB-24DC

2797858
2797861

10
10

COAXTRAB, as surge protection for coaxial cables, connection via
plug and socket
BNC 50 Ω
BNC 50 Ω
BNC 75 Ω

Accessories

Accessories

BNC connector, single-level, for mounting on NS 32 or NS 35/7.5
50 Ω wave impedance
75 Ω wave impedance
BNC connector, double-level, for mounting on NS 32 or NS 35/7.5

BNC-V 50
BNC-V 75

2805041
2805070

10
10

BNC-V 50

2805041

10

50 Ω wave impedance
75 Ω wave impedance

BNC-DV 50
BNC-DV 75

2805038
2805083

10
10

BNC-DV 50

2805038

10

140

PHOENIX CONTACT

Surge protection and interference filters
Surge protection for transceiver systems
BNC connectors

–
–
–
–
–

For coaxial cables
DIN rail-mountable and can be aligned
Single or double-level
Can be labeled individually
With isolated structure on the DIN rail

BNC connector, single-level

BNC connector, double-level

Total width 22 mm

Total width 22 mm

Technical data
General data
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Connection method

BNC-V 50

BNC 50 Ω

Technical data

BNC-V 75
125 °C
IP20
BNC 75 Ω

BNC-DV 50

BNC 50 Ω

Ordering data
Description

Type

BNC-DV 75
125 °C
IP20
BNC 75 Ω

Ordering data
Order No.

Pcs. /
Pkt.

2805041
2805070

10
10

Type

Order No.

Pcs. /
Pkt.

BNC-DV 50
BNC-DV 75

2805038
2805083

10
10

0824949

1

BNC connector, single-level, for mounting on NS 32 or NS 35/7.5
50 Ω wave impedance
75 Ω wave impedance
BNC connector, double-level, for mounting on NS 32 or NS 35/7.5

BNC-V 50
BNC-V 75

50 Ω wave impedance
75 Ω wave impedance

Accessories
Terminal marking, can be labeled according to customer specifications
4-section

ZB 22 CUS

Accessories

0824949

1

ZB 22 CUS

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

141

Surge protection and interference filters
Surge protection for transceiver systems
Protection for antenna inputs of radio
and television equipment
C-SAT-BOX
– Protection for antenna inputs in satellite
receiver technology
– Use before antenna distributor or multiswitch
– Analog and digital SAT signals
– Terrestrial antenna signals
– Direct wall mounting supported
C-TV-SAT and C-TV/HIFI
– Protective adapter for antenna connections
– Use on broadband cable or SAT connection
– TV or F connector

For antenna distributor or multi-switch

Adapter with F and IEC connector

Total width 140 mm

Total width 28 mm

Notes:
For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

IN

OUT

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Shield / Core-Ground
Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Core-Shield / Core-Ground
Cut-off frequency fg (3 dB)
In a 75 Ω system
Symmetrical / Asymmetrical
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method
Test standards

Technical data

B2 / C2 / C3 / D1 / C1
20 V DC / 400 mA (25°C)

F-connector
C1 / C2 / C3 / D1
180 V DC / 130 V AC
1.5 A (25°C)

TV connector
C1 / C2 / C3 / D1
180 V DC / 130 V AC
1.5 A (25°C)

2.5 kA / 2.5 kA
10 kA

2.5 kA / 2.5 kA

2.5 kA / 2.5 kA

≤ 70 V / ≤ 70 V

≤ 600 V / -

≤ 600 V / -

- / > 2.5 GHz

- / > 3 GHz

- / > 1 GHz

140 mm / 74 mm / 35 mm
-40 °C ... 80 °C
IP40
F connector
IEC 61643-21 / EN 50083 - CLASS A

F connector

Ordering data
Description

28 mm / 66 mm / 44 mm
-25 °C ... 75 °C
IP20
V0
PAL-TV (IEC 169-2)
IEC 61643-21 / EN 50083 - CLASS A

Ordering data

Type

Order No.

C-SAT-BOX

2880561

Pcs. /
Pkt.

Type

Order No.

C-TV-SAT
C-TV/HIFI

2856993
2857002

Pcs. /
Pkt.

COAXTRAB, protective device for antenna distributors/multiswitches for insertion in the antenna line
1

COAXTRAB,
surge protection adapter
F connector
TV connector

Accessories

Accessories

Adapter, to connect the C-SAT-BOX with antenna distributors with
a pitch of 20 mm (e.g. ASTRO, SPAUN)
ADAPTER KOAX TYP F

2880972

5

KBL-SAT/20

2880985

5

Connection cable, to connect the C-SAT-BOX with the antenna
distributor, length: 0.2 m

142

PHOENIX CONTACT

1
1

Surge protection and interference filters
Surge protection for transceiver systems
For power supply and antenna inputs

Notes:
For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

– For termination devices
– Easy operation
– Connection to antenna junction box using
separate cable
– Thermal monitoring of the protective circuit
– Green LED - operating indicator for the
power supply
For network and TV antennas/cables and SAT
systems, with F connector and IEC adapter

Total width 63 mm

PE

N

L

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC
Nominal current IN
Nominal discharge surge current In (8/20) µs
Core-Shield / Core-Ground
Combined surge UOC
Protection level UP
Core-Shield / Core-Ground
Output voltage limitation at 1 kV/µs
Core-Ground / Core-Shield / Shield-Ground
Cut-off frequency fg (3 dB)
In a 75 Ω system
Core/Shield
General data
Dimensions W / H / D
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Connection method
Test standards

Mains protection
III / T3
230 V AC
360 V AC (L/N-PE)
16 A (30 °C)

Data protection
C2 / C3 / D1
50 V AC / 72 V DC
1.5 A (25°C)

3 kA / 3 kA
4 kV

2.5 kA / 2.5 kA
-

≤ 1.2 kV / ≤ 1.5 kV

≤ 700 V (C2 - 2 kA) / -

-/-

- / ≤ 700 V / ≤ 1 kV

-

> 2.5 GHz

IEC 61643-1

63 mm / 79 mm / 106.5 mm
-25 °C ... 75 °C
IP20 (child-proof)
V0/HB
F connector
IEC 61643-21

Ordering data
Description

Can be used as typical for
the country

Type

Order No.

MNT-TV-SAT D
MNT-TV-SAT D/WH
MNT-TV-SAT B/F
MNT-TV-SAT S/WH

2882284
2882297
2882307
2880888

Pcs. /
Pkt.

MAINTRAB, surge protection attachment plug for plugging into a
socket for equipment and data interface protection, incl. 1.5 m
coaxial cable.
Black
White
Black
White

D, A, NL
D, A, NL
B, F, CZ, SVK, PL
S, FIN, N

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1
1
1
1

143

Surge protection and interference filters
EMC solutions
SFP-TRAB

Reliable signals with mains interference filter
Switching operations triggered mechanically or electronically generate pulse-like
and high-frequency interference voltages.
These voltages spread in an unimpeded
manner across the cable network. All the
devices within this cable network are affected. Data errors, uncontrolled functions, and
system crashes can result, with data processing devices at particular risk.

144

PHOENIX CONTACT

Interference voltage filters for power
supply units
Interference filters limit conducted highfrequency interference voltages. Devices
used in data processing or automation particularly benefit from a clean power supply.
The end result is safe operation and reliable
measured results.

Interference filters with type 3 surge
protection
Interference filters with integrated type 3
surge protection have two tasks: they absorb surge voltages and also limit high-frequency interference voltages.

Surge protection and interference filters
EMC solutions

Mains interference filters - operating
principle and range
Filtering of symmetrical disturbance
variables
X - Interference voltages between the
phase and neutral conductor are filtered.

Operating range of filters
An attenuation curve diagram illustrates
the effective operating range of mains interference filters. The relevant frequency-dependent attenuation can be read according
to the symmetrical or asymmetrical filter
circuit.

Filtering of asymmetrical disturbance
variables
Y1,Y2 - The opposite grounded interference voltages from phase to PE and from
the neutral conductor to PE are filtered.

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

145

Surge protection and interference filters
EMC solutions
DIN-rail-mountable device protection
with SFP-TRAB interference filter

Notes:

H

For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

– Combined protective circuit for absorbing transient surge voltages and high-frequency interference voltages
– Thermal monitoring of the protective circuit
– Disconnection status signaled via floating
remote indication contact
– Can be installed in industrial environments

W

D

20 A nominal current

Total width 112 mm
NO
14
COM 11
NC
12

L

IN

L
J

J

OUT

N

N

Technical data
Electrical data
IEC category / EN type
Nominal voltage UN
Maximum continuous operating voltage UC
Nominal load current IL
Nominal discharge surge current In (8/20) µs
Max. discharge surge current Imax. (8/20) µs
Combined surge UOC
Protection level UP
Response time tA
Backup fuse max. in acc. with IEC
Input attenuation aI

DC/AC
L-N / L-PE
L-N / L-PE
L-N/L(N)-PE
L-N/L(N)-PE

Symmetrical
Asymmetrical
Inductivity
General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards

... 230AC
III / T3
230 V AC
- / 264 V AC
20 A (40°C)
5 kA / 5 kA
10 kA / 10 kA
10 kV
≤ 1 kV / ≤ 1 kV
≤ 25 ns / ≤ 25 ns
20 A (gL / gG)

... 120AC
III / T3
120 V AC
- / 150 V AC
20 A (40°C)
3 kA / 3 kA
10 kA / 10 kA
6 kV (3 kA)
≤ 450 V / ≤ 450 V
≤ 25 ns / ≤ 25 ns
20 A (gL / gG)

20 dB (≥ 100 kHz / 50 Ω)
30 dB (≥ 1 MHz / 50 Ω)
2x 1 mH ±30 % (with current
compensation)

Typ. 40 dB (≥ 500 kHz / 50 Ω)
Typ. 30 dB (≥ 1 MHz / 50 Ω)
2x 1 mH ±30 % (with current
compensation)

112 mm / 93 mm / 79 mm
4 ... 6 mm² / 4 ... 4 mm² / 12 - 10
-40 °C ... 70 °C
-25 °C ... 40 °C
V0
IEC 61643-1 / DIN EN 61643-11 / EN 61643-11/A11 /
UL 1449 / UL 1283
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 1 A (250 V AC) / 0.25 A (250 V DC) / 1 A (48 V DC)

Remote indication contact
Connection data solid / stranded / AWG
Max. operating voltage
Max. operating current

Ordering data
Description

Voltage UN

Type

Order No.

SFP 1-20/230AC
SFP 1-20/120AC

2859987
2856702

Pcs. /
Pkt.

SFP-TRAB, DIN rail-mountable device protection with integrated
mains interference filter and optical signaling
Nominal current: 20 A
230 V AC
Nominal current: 20 A
120 V AC
SFP-TRAB, DIN rail-mountable device protection with integrated
mains interference filter and optical signaling
Nominal current: 5 A
Nominal current: 10 A
Nominal current: 15 A

146

PHOENIX CONTACT

120 V AC
120 V AC
120 V AC

1
1

Surge protection and interference filters
EMC solutions
H

H
W

D

H
W

D

5 A nominal current

10 A nominal current

Total width 112 mm

15 A nominal current

Total width 112 mm

Total width 112 mm

NO
14
COM 11
NC
12

L

IN

NO
14
COM 11
NC
12

L

L
J

W

D

J

OUT

N

N

IN

NO
14
COM 11
NC
12

L

L
J

J

OUT

N

N

Technical data

IN

L
J

J

N

N

Technical data

Technical data

III / T3
120 V AC
- / 150 V AC
5 A (72°C)
3 kA / 3 kA
10 kA / 10 kA
6 kV (3 kA)
≤ 450 V / ≤ 450 V
≤ 25 ns / ≤ 25 ns
20 A (gL / gG)

III / T3
120 V AC
- / 150 V AC
10 A (62°C)
3 kA / 3 kA
10 kA / 10 kA
6 kV (3 kA)
≤ 450 V / ≤ 450 V
≤ 25 ns / ≤ 25 ns
20 A (gL / gG)

III / T3
120 V AC
- / 150 V AC
15 A (52 °C)
3 kA / 3 kA
10 kA / 10 kA
6 kV (3 kA)
≤ 450 V / ≤ 450 V
≤ 25 ns / ≤ 25 ns
20 A (gL / gG)

Typ. 40 dB (≥ 500 kHz / 50 Ω)
Typ. 30 dB (≥ 1 MHz / 50 Ω)
2x 1 mH ±30 % (with current compensation)

Typ. 40 dB (≥ 500 kHz / 50 Ω)
Typ. 30 dB (≥ 1 MHz / 50 Ω)
2x 1 mH ±30 % (with current compensation)

Typ. 40 dB (≥ 500 kHz / 50 Ω)
Typ. 30 dB (≥ 1 MHz / 50 Ω)
2x 1 mH ±30 % (with current compensation)

112 mm / 93 mm / 79 mm
4 ... 6 mm² / 4 ... 4 mm² / 12 - 10
-25 °C ... 70 °C
V0
IEC 61643-1 / EN 61643-11/A11 / UL 1449 /
UL 1283
PDT, 1-pos.
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 1 A (250 V AC) / 0.25 A (250 V DC) / 1 A (48 V DC)

112 mm / 93 mm / 79 mm
4 ... 6 mm² / 4 ... 4 mm² / 12 - 10
-25 °C ... 60 °C
V0
IEC 61643-1 / EN 61643-11/A11 / UL 1449 /
UL 1283
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 1 A (250 V AC) / 0.25 A (250 V DC) / 1 A (48 V DC)

112 mm / 93 mm / 79 mm
4 ... 6 mm² / 4 ... 4 mm² / 12 - 10
-25 °C ... 50 °C
V0
IEC 61643-1 / EN 61643-11/A11 / UL 1449 /
UL 1283
PDT
0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16
250 V AC / 1 A (250 V AC) / 0.25 A (250 V DC) / 1 A (48 V DC)

Ordering data

Ordering data

Type

Order No.

SFP 1-5/120AC

2920667

Pcs. /
Pkt.

OUT

Ordering data

Type

Order No.

SFP 1-10/120AC

2920670

Pcs. /
Pkt.

Type

Order No.

SFP 1-15/120AC

2920683

Pcs. /
Pkt.

1
1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1

147

Surge protection and interference filters
EMC solutions
TERMITRAB

Notes:

H

For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

– Combined protective circuit for absorbing transient surge voltages and high-frequency interference voltages
– With spring-cage connection
– Disconnection of signal circuits by disconnect knife

W

D

Protection for two conductors with a common
reference potential

Total width 6.2 mm
1

3

OUT

IN

2

4

Technical data
Electrical data
IEC category / EN type
Maximum continuous operating voltage UC
Nominal load current IL
Nominal discharge surge current In (8/20) µs

DC/AC

C1 / C3
38 V DC / 30 V AC
0.5 A (55°C)

Core-Ground

350 A
700 A

Core-Ground

≤ 70 V

Total surge current (8/20) µs
Output voltage limitation at 1 kV/µs
Cut-off frequency fg (3 dB)
Asymmetrical in the 50 Ω system
Resistance per path
Inductance per path
Capacitance per path
General data
Connection data solid / stranded / AWG
Temperature range
Degree of protection in acc. with IEC 60529/ EN 60529
Inflammability class in acc. with UL 94
Test standards

Typ. 60 kHz
0.5 Ω
100 µH (per path)
130 nF
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-40 °C ... 85 °C
IP20
V2
IEC 61643-21/A1 / EN 61643-21/A1

Ordering data
Description

Voltage UN

TERMITRAB, spring-cage modular terminal block with integrated
surge protection as a filter circuit and disconnect knives, for mounting on NS 35
24 V AC

Type

TT-ST-M-SFP-24AC

Order No.

Pcs. /
Pkt.

2858946

10

2858894

50

Accessories
Cover, for terminating a row of terminal blocks
TT-D-STTCO-BK
Zack marker strip, 10-section, white

148

PHOENIX CONTACT

ZB 6, see page 111

Surge protection and interference filters
EMC solutions
FILTRAB
H

H

– Low pass filters for nominal currents of 1
to 10 A
– For single-phase circuits
– Rail-mountable module

W

D

W

D

Notes:
For certifications, see page 154
Attenuation characteristics at www.phoenixcontact.net/products

1 A / 3 A nominal current

6 A / 10 A nominal current

Total width 25 mm

Total width 40 mm

1

3

1

OUT

IN

2

3

OUT

IN

4

2

4

Technical data
Electrical data
Nominal voltage UN
Maximum continuous operating voltage UC
Nominal load current IL
Backup fuse max. in acc. with IEC
Inductivity
Input attenuation aI

L-N

Symmetrical
Asymmetrical

NEF 1- 3
240 V AC
264 V AC
3 A (40°C)
3 A (gL)
2x 2.7 mH

NEF 1- 6
240 V AC
264 V AC
6 A (40°C)
6.3 A (gL/C)
2x 2.7 mH

NEF 1-10
240 V AC
264 V AC
10 A (40°C)
10 A (gL)
2x 1.8 mH

≥ 65 dB (50 Ω/ 1 MHz)
≥ 45 dB (50 Ω/ 1 MHz)

≥ 55 dB (50 Ω/ 1 MHz)
≥ 35 dB (50 Ω/ 1 MHz)

> 80 dB (50 Ω/ 1 MHz)
> 40 dB (50 Ω/ 1 MHz)

> 80 dB (50 Ω/ 1 MHz)
> 40 dB (50 Ω/ 1 MHz)

General data
Dimensions W / H / D
Connection data solid / stranded / AWG
Temperature range
Inflammability class in acc. with UL 94
Test standards

Description

Nominal load
current IL

Technical data

NEF 1- 1
240 V AC
264 V AC
1 A (40°C)
1 A (gL)
2x 10 mH

25 mm / 79.4 mm / 84.15 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-25 °C ... 100 °C (HMF)
V2
IEC 60939-2 / DIN EN 60939-2

40 mm / 79.4 mm / 84.1 mm
0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12
-25 °C ... 100 °C (HMF)
V2
IEC 60939-2 / DIN EN 60939-2

Ordering data

Ordering data

Type

Order No.

Pcs. /
Pkt.

2794123
2794110

10
10

Type

Order No.

NEF 1- 6
NEF 1-10

2783082
2788977

Pcs. /
Pkt.

FILTRAB, interference filter for single-phase current circuits, for
mounting on NS 32 or NS 35...
1A
3A
6A
10 A

NEF 1- 1
NEF 1- 3

Accessories
Labeling material

For ZB 5..., see page 111

5
5

Accessories
For ZB 5..., see page 111

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

149

Surge protection and interference filters
Test device
CHECKMASTER –
the arrester test system
Lightning protection systems must be
regularly tested in accordance with the requirements of IEC 62305-3 and official regulations. A basic visual check is not enough
to identify surge protective devices that
were previously damaged. Only an electrical
check using the CHECKMASTER produces
meaningful results. The test device checks
all the relevant components of an arrester.
The nominal data of protective elements,
such as spark gaps, varistors, gas-filled surge
arresters, and suppressor diodes, is tested
in a single test cycle.

The CHECKMASTER offers real advantages
for safety in all sectors where a high level of system availability is crucial.

4-line LCD

Robust keypad

Sturdy case with a flight
case design

Interface to printer or
computer

Replaceable test sockets

150

PHOENIX CONTACT

Item identification via barcode and handheld scanner

Surge protection and interference filters
Test device

User-friendly and reliable testing of plug-in arresters in just four steps
1. Easy selection
The CHECKMASTER has a modular design. Various test sockets are compatible
with the various plugs. Further information
about the test sockets required can be
found on the next page.

2. User-friendly scanning
The barcodes on the surge protective
devices present a fast and error-free solution for entering items. System-specific abbreviations or user-defined IDs can be entered via the operator interface or read in
from the individually created barcode labels.

3. Safe testing
When started, an automatic test process is run which checks the arresters with regard to their specific electrical properties. The results are
visualized via the display and via two signal lamps.

Status:
OK

The protective plug is OK and can be used.

Status:
Tolerance limit
reached

4. Fast logging
The tests are documented according to
IEC 62305-3. In addition to the immediate
processing of all test values, the CHECKMASTER also allows the contents of the internal memory to be exported directly to
an Excel worksheet, for example.

The protective plug has been damaged – replacement is recommended.

Status:
Faulty

The protective plug is faulty and must be replaced.

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

151

Surge protection and interference filters
Test device
CHECKMASTER

Notes:
Dimensional drawing at: www.phoenixcontact.net/products

– Modular test device for virtually all plug-in
surge arresters from Phoenix Contact
– Corresponding test sockets are available
for the arrester connectors
– Test sockets can be easily changed
– Easy operation thanks to barcode scanner
or keypad
– Optional entry of system-specific name
for protective devices
– Documentation of test results

The programming cable has a special pin assignment. It can be
used only to update the CHECKMASTER software!
1) EMC: Class A product, see page 287

Arrester test device

The test socket for PLUGTRAB PT
is included in the scope of supply of
the CHECKMASTER.

Total width 450 mm

Technical data

Case for transporting test sockets
PA-CASE
– Six padded compartments
– Sufficient space for all connecting cables
– The test adapters are not supplied as
standard with the PA-CASE.
CM-KBL-RS232/USB
– Adapter cable
– For connection of the test device to a laptop/PC

Nominal voltage UN
Ambient temperature (operation)
Degree of protection
Interface

Ordering data
Description

Free software for updating
CHECKMASTER can be found at the
Download Center on Phoenix Contact's
homepage.
The operation of the CHECKMASTER
and that of the CM-PA sockets do not meet
the general protection requirements for
residential areas. Please take the appropriate precautions.

152

PHOENIX CONTACT

Type

Order No.

CHECKMASTER1)

2838924

Pcs. /
Pkt.

Test device, for the function test of TRABTECH protective
devices, incl. CM-PA-PT for PLUGTRAB PT

Transport case, to accommodate 6 TRABTECH test adapters
CM-PA...
TRABTECH test adapter, for testing the function of:

CM-KBL-PROG
– Necessary for updating CHECKMASTER
firmware

230 V AC (100 V AC ... 240 V AC)
5 °C ... 35 °C
IP20
RS-232

FLASHTRAB compact and VALVETRAB compact
COMTRAB CTM
COMTRAB CT 10
PLUGTRAB PT
PLUGTRAB UFBK, UAK
TF-TRAB
VALVETRAB
USB RS232 converter,
D-SUB, 9-pos. to USB, type A, 4-pos.
D-SUB adapter, 25-pos. to D-SUB, 9-pos.
Update cable, for CHECKMASTER firmware updates

1

Surge protection and interference filters
Test device

Transport case for test sockets

Test sockets

Data cable

Ordering data

Ordering data

Ordering data

Type

Order No.

PA-CASE

2858988

Pcs. /
Pkt.

Type

Order No.

CM-PA-FLT/VAL-CP1)
CM-PA-CTM1)
CM-PA-CT101)
CM-PA-PT1)
CM-PA-PT/A1)
CM-PA-TF1)
CM-PA-VAL-MS1)

2880392
2816962
2816959
2882844
2816933
2816975
2800104

Pcs. /
Pkt.

Pcs. /
Pkt.

Type

Order No.

CM-KBL-RS232/USB

2881078

1

CM-KBL-PROG

2881557

1

1

1
1
1
1
1
1
1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

153

Surge protection and interference filters
Approvals
Type

Order No. Certification

B
BNC-DV 50

2805038

BNC-DV 75

2805083

BNC-V 50

2805041

BNC-V 75

2805070

BT-1S-230AC/A

2803409

BT-1S-230AC/O

2800625

BT-SKT 230/A

2859343





    CCA 
   CCA 


C
CHECKMASTER

2838924

CM-KBL-PROG

2881557

CM-KBL-RS232/USB

2881078

CM-PA-CT10

2816959

CM-PA-CTM

2816962

CM-PA-FLT/VAL-CP

2880392

CM-PA-PT

2882844

CM-PA-PT/A

2816933

CM-PA-TF

2816975

CN-LAMBDA/4-0.47-BB

2800021

CN-LAMBDA/4-0.47-SB

2800022

CN-LAMBDA/4-5.9-BB

2838490

CN-LAMBDA/4-5.9-SB

2800023

CN-UB/E

2763691

CN-UB/E-BB

2817686

CN-UB/MP

2818135

CN-UB/MP-90DEG-50

2803137

CN-UB-70DC-6-BB

2803166

CN-UB-70DC-6-SB

2803153

C-SAT-BOX

2880561

CT 1-10-ES

2765547

CT 10-18FS+F/PE-24

2807926

CT 10-18FSR+F/PE-24

2807939

CT 10-2/2-GS

2765398

CT 10-2/2-GS/3E

2765408

CT 10-2/2-GS/3E-110AC

2920829

CT 10-2PE/FS-24

2807955

CT 10-2PE/FSR-24

2807968

CT 10-9VA-230AC

2830498

CT 10-MB/ 3

2765372

CT 10-MB/10

2765385

CT 10-TL

2765356

CTM 10-MAG

2838610

CTM 1X2- 12DC

2838597

CTM 1X2- 24DC

2838513

CTM 1X2- 60DC

2838568

CTM 1X2-110AC

2838539

CTM 2X1- 12DC

2838584

CTM 2X1- 24DC

2838500

CTM 2X1- 5DC

2838571

CTM 2X1- 60DC

2838542

CTM 2X1-110AC

2838526

CTM 2X1-180DC-GS

2838636

154

PHOENIX CONTACT













































Type

Order No. Certification

CTM 2X1-180DC-GS-P

2838623

CTM EST

2838649

CTM ISDN

2838555

CT-TERMIBLOCK 10 DA

0441711

C-TV/HIFI

2857002

C-TV-SAT

2856993

C-UB/E

2763701

C-UFB- 5DC

2797858

C-UFB- 5DC/E

2782300

C-UFB- 5DC/E 75

2763604

C-UFB-24DC

2797861

C-UFB-24DC/E

2782313














D
D-DEK 1,5 BK

2838995

D-DEK 1,5 BU

2838982

D-DS1-A/RJ45-BB

2838050

DK-BIC-35

2749880

D-LAN-19"-12

2880150

D-LAN-19"-16

2880147

D-LAN-19"-20

2880134

D-LAN-19"-24

2838791

D-LAN-19"-4

2880176

D-LAN-19"-8

2880163

D-LAN-19"-D-P

2880192

D-LAN-CAT.5-FP

2800723

DP-UKK 3/5 BK

2770833

D-TERMITRAB-UK 5

2794990

DT-LAN-CAT.6+

2881007

DT-TELE-RJ45

2882925

DT-UFB-485/BS

2920612

DT-UFB-IB-RB0

2800056

DT-UFB-IB-RBI

2800055

DT-UFB-V24/S-9-SB

2803069

DT-UFB-V24/S-SB-SET

2803072

D-UFB-PB

2880642

D-UKK 3/5 BK

2770228

























F
FLT 100 N/PE-1.5

2800303

FLT 100 N/PE-1.5

2800303

FLT-CP-1C-350

2859741

FLT-CP-1S-350

2859738

FLT-CP-2C-350

2859770

FLT-CP-2S-350

2859767

FLT-CP-350-ST

2881887

FLT-CP-3C-350

2859725

FLT-CP-3S-350

2859712

FLT-CP-N/PE-350

2859754

FLT-CP-N/PE-350-ST

2859686

FLT-CP-PLUS-1C-350

2882695

FLT-CP-PLUS-1S-350

2882682

FLT-CP-PLUS-2C-350

2882679

FLT-CP-PLUS-2S-350

2882666

FLT-CP-PLUS-350-ST

2859913



   CCA 
    CCA 
   CCA 
   CCA 
   CCA 
    CCA 
    CCA 
   CCA 
   CCA 






Surge protection and interference filters
Approvals
Type

Order No. Certification

FLT-CP-PLUS-3C-350

2882653

FLT-CP-PLUS-3S-350

2882640

FLT-PLUS CTRL-2.5

2800121

FLT-PLUS CTRL-2.5/I

2800122

FLT-PLUS CTRL-3.0

2800168

FLT-PLUS CTRL-3.0/I

2800170

F-MS 12

2817987

F-MS 12 ST

2817990

F-MS 12/FM

2817974

F-MS 2200/30 ST

2805392

F-MS 80 ST

2921307

F-MS-T1/T2 50 ST

2800191



    CCA 
    CCA 
    CCA 
    CCA 
     CCA 
     CCA 
     CCA 
    CCA 
   CCA 
   CCA 

K
KBL-SAT/20

2880985



L
LIT 1X2-24

2804610

LIT 2-12

2804694

LIT 2-24

2804665

LIT 2X1-24

2804636

LIT 2X2-24

2804623

LIT 4-12

2804704

LIT 4-24

2804678

LIT 4X1-24

2804649

  Ex:  
  Ex:  
  Ex:  

  Ex:  
  Ex:  
  Ex:  


M
ME 6,2 TBUS-2 1,5/5-ST3,81KMGY

2969401

MINI MCR-SL-V8-FLK 16-A

2811268

MNT-1 CH II

2882255

MNT-1 D

2882200

MNT-1 D/WH

2882213

MNT-1 E

2882239

MNT-1 S/WH

2880862

MNT-ISDN D

2882336

MNT-ISDN D/WH
MNT-ISDN S/WH

2882349
2880891

MNT-NET B/F

2882226

MNT-POWERLINE

2858001

MNT-TAE D

2882381

MNT-TAE D/WH

2882394

MNT-TEL B/F

2882404

MNT-TELE E

2882417

MNT-TELE N/WH

2881764

MNT-TELE S/WH

2880901

MNT-TV-SAT B/F

2882307

MNT-TV-SAT D

2882284

MNT-TV-SAT D/WH
MNT-TV-SAT S/WH

2882297
2880888


  Ex: 





















Type

Order No. Certification

PRT-CD-AD1

2749673

PT 1X2- 5DC-ST

2856016

PT 1X2+F-BE

2856126

PT 1X2-12AC-ST

2856045

PT 1X2-12DC-ST

2856029

PT 1X2-24AC-ST

2856058

PT 1X2-24DC-ST

2856032

PT 1X2-48DC-ST

2803658

PT 1X2-BE

2856113

PT 2+1-S-48DC/FM

2817958

PT 2+1-S-48DC-ST

2839648

PT 2-F-ST

2859000

PT 2-IT-230AC/FM

2805130

PT 2-IT-230AC-ST

2805127

PT 2-PE/S- 24AC-ST

2839318

PT 2-PE/S- 60AC-ST

2839321

PT 2-PE/S-120AC/FM

2856812

PT 2-PE/S-120AC-ST

2839334

PT 2-PE/S-230AC/FM

2858357

PT 2-PE/S-230AC-ST

2839347

PT 2-PE/S-24AC/FM

2800457

PT 2-TELE

2882828

PT 2-TELE-ST

2838733

PT 2X1- 5DC-ST

2856061

PT 2X1+F-BE

2856142

PT 2X1-12AC-ST

2856090

PT 2X1-12DC-ST

2856074

PT 2X1-24AC-ST

2856100

PT 2X1-24DC-ST

2856087

PT 2X1-BE

2856139

PT 2X1VA- 60AC-ST

2839172

PT 2X1VA-120AC-ST

2839185

PT 2X1VA-230AC-ST

2839198

PT 2X1-VF-120AC

2859327

PT 2X1-VF-120AC-ST

2856799

PT 2X1-VF-230AC

2805460

PT 2X1-VF-230AC-ST

2921365

PT 2X2- 5DC-ST

2838241

PT 2X2+F-BE

2839224

PT 2X2-12AC-ST

2838270

PT 2X2-12DC-ST

2838254

PT 2X2-24AC-ST

2838283

PT 2X2-24DC-ST

2838228

PT 2X2-BE

2839208

PT 2X2-HF- 5 DC-ST

2839567

PT 2X2-HF-12 DC-ST

2839570

PT 2X2-HF-24 DC-ST

2839729

N
NEF 1- 1

2794123

NEF 1- 3

2794110

NEF 1- 6

2783082

NEF 1-10

2788977






PT 2XEX(I)-24DC-ST

2838225

PT 2XEX(I)-BE

2839279

PT 3-HF-12DC-ST

2858043

PT 3-PB-ST

2858030

PT 4- 5DC-ST

2839211

PT 4+F-BE

2839415

PT 4-12DC-ST

2839237

P
PAS-1

2765615



For additional information, visit www.phoenixcontact.net/products


  Ex:  
   Ex:  
  Ex:  
   Ex:  
  Ex:  
   Ex:  

   Ex:  





      CCA  Ex: 
     CCA  Ex: 
     CCA  Ex: 
     CCA  Ex: 
      CCA  Ex: 
     CCA  Ex: 



  Ex: 
   Ex: 
  Ex: 
   Ex: 
  Ex: 
   Ex: 
   Ex: 







  Ex:  
   Ex:  
  Ex:  
  Ex:  
   Ex:  
   Ex:  
   Ex:  
  Ex: 
   Ex: 
  Ex: 
  Ex:    
  Ex:  


  Ex: 
   Ex:  
  Ex: 
PHOENIX CONTACT 155

Surge protection and interference filters
Approvals
Type

Order No. Certification

PT 4-12DC-ST

2839237

PT 4-24DC-ST

2839240

Type

Order No. Certification

T

PT 4-BE

2839402

PT 4-EX(I)-24DC-ST

2839253

PT 4-EX(I)-BE

2839486

PT 4-F-ST

2858441

PT 4-PE/S-230AC/FM

2882459

PT 4-PE/S-230AC-ST

2882462

PT 4X1- 5DC-ST

2838306

PT 4X1+F-BE

2839376

PT 4X1-12AC-ST

2838348

PT 4X1-12DC-ST

2838319

PT 4X1-24AC-ST

2838351

PT 4X1-24DC-ST

2838322

PT 4X1-48AC-ST

2804856

PT 4X1-48DC-ST

2858014

PT 4X1-BE

2839363

PT 5-HF- 5 DC-ST

2838762

PT 5-HF-12 DC-ST

2838775

PT MAIN-EST

2880736

PT MCR-EST

2880749

PT PE/S+1X2-24-ST

2819008

PT PE/S+1X2-BE

2856265

PT-BE/FM

2839282

  Ex: 
   Ex: 
   Ex:  
 Ex:   
 Ex: 



  Ex: 
   Ex: 
  Ex: 
  Ex: 
  Ex: 
   Ex: 


   Ex: 
  Ex: 
   Ex: 




      CCA  Ex: 

S

S-PT-2XEX-48DC

2800038

S-PT-4-EX-24DC

2800036

S-PT-EX(I)-24DC

2880671

S-PT-EX(I)-24DC-1/2"

2882572

S-PT-EX(I)-24DC-3/4"

2882585

S-PT-EX-24DC

2800034

S-PT-EX-48DC

2800053

SVP 2E- 48AC

2788919

SVP 2E-110AC

2765534

SVP 3E-110AC

2765521









Ex:  
Ex:  
Ex:  
 Ex:   
 Ex:   
 Ex:   
Ex:  
Ex:  




SYS N4 120/208Y

2800704

SYS N4 120/240HLD

2800706

SYS N4 120/240S

SFP 1-10/120AC

2920670

SFP 1-15/120AC

2920683

SFP 1-20/120AC

2856702

SFP 1-20/230AC

2859987

SFP 1-5/120AC

2920667

S-PT-1X2-24DC

2880668

S-PT-1X2-24DC-1/2"

2882569

S-PT-1X2-24DC-3/4"

2882598

S-PT-2XEX-24DC

2800040

TAE-TRAB FM-NFN-AP

2749628

TT-2/2- 24DC

2838173

TT-2/2-M-24DC

2920722

TT-2-PE- 24DC

2838186

TT-2-PE/S1- 24DC

2839538

TT-2-PE/S1-M-24DC

2920638

TT-2-PE-110AC

2858483

TT-2-PE-M-24DC

2920641

TT-D-2-PE-M-BK

2920654

TT-D-2-PE-M-BU

2803878

TT-D-ST-BU

2856773

TT-D-STTCO-BK

2858894

TT-EX(I)- 24DC

2832124

TT-EX(I)-M-24DC

2803865

TT-SLKK5/ 12DC

2794893

TT-SLKK5/ 24DC

2794903

TT-SLKK5/ 48DC

2794916

TT-SLKK5-F/110AC

2765602

TT-SLKK5-S- 12DC

2809597

TT-SLKK5-S- 24DC

2809607

TT-SLKK5-S- 48DC

2809610

TT-ST-2/2-24DC

2858881

TT-ST-2-PE-24DC

2858878

TT-ST-M-2/2-24AC

2858933

TT-ST-M-2/2-24DC

2858917

TT-ST-M-2-PE-24AC

2858920

TT-ST-M-2-PE-24DC

2858904

TT-ST-M-EX(I)-24DC

2859424

TT-ST-M-SFP-24AC

2858946

TT-UK5/ 12DC

2794686

TT-UK5/ 24DC

2794699

TT-UK5/ 48DC

2794709

TT-UKK5-M/ 24DC

2795960

TT-UKK5-M/ 48DC

2795973

TT-UKK5-M/ 60DC

2795986

V
VAL-CP-175-ST

2859628

VAL-CP-1S-175

2859479

VAL-CP-1S-350

2859563

VAL-CP-1S-350/O

2881036

VAL-CP-2C-175

2859482

VAL-CP-2C-350

2859589

VAL-CP-2C-350/O

2881052

VAL-CP-2S-175

2859495



VAL-CP-2S-350

2859505



VAL-CP-2S-350/O

2881049

2800705



VAL-CP-350-ST

2859602

SYS N4 277/480Y

2800703



VAL-CP-350-ST-GY

2882718

SYS N4 480D

2800707



VAL-CP-3C-175

2859466

SYS N4X 120/240HLD

2800716



VAL-CP-3C-350

2859547

SYS N4X 120/240S

2800715



VAL-CP-3C-350/O

2881023

SYS N4X 277/480Y

2800713



VAL-CP-3S-175

2859453

156

PHOENIX CONTACT


   Ex: 

   Ex: 








  Ex:    
Ex:  













 Ex:   
























Surge protection and interference filters
Approvals
Type

Order No. Certification

VAL-CP-3S-350

2859521

VAL-CP-3S-350/O

2881010

VAL-CP-MCB-1S-350/40/FM

2882763

VAL-CP-MCB-3C-350/40/FM

2882776

VAL-CP-MCB-3S-350/40/FM

2882750

VAL-CP-MOSO 60-3C-FM

2804416

VAL-CP-MOSO 60-3S-FM

2804403

VAL-CP-N/PE-350-ST

2859699

VAL-CP-N/PE-350-ST-GY

2882734

VAL-CP-RCD-3S/40/0.03

2882802

VAL-CP-RCD-3S/40/0.3/SEL

2808001

VAL-MS 60 ST

2807573

VAL-MS 1000PV ST

2805185

VAL-MS 120 ST

2807586

VAL-MS 230

2839127

VAL-MS 230 IT ST

2807599

VAL-MS 230 ST

2798844

VAL-MS 230/1+1

2804429

VAL-MS 230/1+1-FM

2804432

VAL-MS 230/2+0

2800103

VAL-MS 230/2+0-FM

2800102

VAL-MS 230/3+1

2838209

VAL-MS 230/3+1 FM

2838199

VAL-MS 230/FM

2839130

VAL-MS 320 ST

2838843

VAL-MS 320/1+1

2804380

VAL-MS 320/1+1-FM

2804393

VAL-MS 320/3+0

2920230

VAL-MS 320/3+0-FM

2920243

VAL-MS 320/3+1

2859178

VAL-MS 320/3+1/FM

2859181

VAL-MS 320/3+1/FM-UD

2856689

VAL-MS 320-UD ST

2858315

VAL-MS 350 VF ST

2856595

VAL-MS 350 VF/FM

2856579

VAL-MS 350VF

2856582

VAL-MS 385/65 ST

2920308

VAL-MS 385/65/1+1

2921255

VAL-MS 385/65/1+1-FM

2921242

VAL-MS 385/65/3+0

2921019

VAL-MS 385/65/3+0-FM

2921006

VAL-MS 385/65/3+1

2920890

VAL-MS 385/65/3+1-FM

2920887

VAL-MS 385/80 ST

2920353

VAL-MS 385/80/1+1

2921297

VAL-MS 385/80/1+1-FM

2921284

VAL-MS 385/80/3+0

2921093

VAL-MS 385/80/3+0-FM

2921080

VAL-MS 385/80/3+1

2920971

VAL-MS 385/80/3+1-FM

2920968

VAL-MS 400 ST

2816399

VAL-MS 500 ST

2807609

VAL-MS 580/3+0

2920450

Type



    CCA 
    CCA 
    CCA 




    CCA 
    CCA 
     CCA 

     CCA 
     CCA 
     CCA 
      CCA 




     CCA 
     CCA 
     CCA 
     CCA 


    CCA 
    CCA 
     CCA 
     CCA 


    CCA 
    CCA 
    CCA 
    CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
    CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
     CCA 
      CCA 
    CCA 

Order No. Certification

VAL-MS 580/3+0-FM

2920447

VAL-MS 580-ST

2920434

VAL-MS 60

2868020

VAL-MS 60/FM

2868033

VAL-MS 75 VF ST

2805318

VAL-MS 750/30/3+0

2920269

VAL-MS 750/30/3+0-FM

2920272

VAL-MS 750/30-ST

2920256

VAL-MS 800/30 VF/FM

2805402

VAL-MS BE

2817741

VAL-MS BE/FM

2817738

VAL-MS/2+0-BE

2804584

VAL-MS/2+0-BE/FM

2805321

VAL-MS/3+0-BE

2881816

VAL-MS/3+0-BE/FM

2881803

VAL-MS-T1/T2 175/12.5 ST

2800676

VAL-MS-T1/T2 175/12.5/1+1

2800675

VAL-MS-T1/T2 175/12.5/1+1-FM

2800674

VAL-MS-T1/T2 175/12.5/3+0

2800673

VAL-MS-T1/T2 175/12.5/3+0-FM

2800672

VAL-MS-T1/T2 175/12.5/3+1

2800671

VAL-MS-T1/T2 175/12.5/3+1-FM

2800670

VAL-MS-T1/T2 335/12.5 ST

2800190

VAL-MS-T1/T2 335/12.5/1+1

2800187

VAL-MS-T1/T2 335/12.5/1+1-FM

2800186

VAL-MS-T1/T2 335/12.5/3+0

2800189

VAL-MS-T1/T2 335/12.5/3+0-FM

2800188

VAL-MS-T1/T2 335/12.5/3+1

2800184

VAL-MS-T1/T2 335/12.5/3+1-FM

2800183

VAL-MS-T1/T2 335/12.5/4+0

2800645

VAL-MS-T1/T2 335/12.5/4+0-FM

2800644

VAL-US 120 ST

2800739

VAL-US 240 ST

2800740

VAL-US 277 ST

2800741

VAL-US 347 ST

2800742

VAL-US 480 ST

2800743

VAL-US 60 ST

2800738

    CCA 
    CCA 



     CCA 
     CCA 
     CCA 
   CCA 
      CCA 
      CCA 


     CCA 
     CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 
   CCA 









W
WT-RJ 12-S/FM A/K AP

2809186

WT-RJ 45-S/ISDN1/K AP

2809830

For additional information, visit www.phoenixcontact.net/products




PHOENIX CONTACT

157

158

PHOENIX CONTACT

Power supply units and UPS
For maximum system availability
Power supply units
Thanks to high-quality products featuring
leading technology, our QUINT, TRIO,
MINI, UNO, and STEP POWER product
ranges optimally equip you for international
competition.

Power supply units and UPS
Selection guide

160

Power supply units

164

QUINT POWER

166

TRIO POWER

174

MINI POWER

180

UNO POWER

184

STEP POWER

186

QUINT POWER, dip-coated

194

DC/DC converters

196

QUINT DC/DC converters

198

DC/DC converter, dip-coated

200

MINI DC/DC converter

202

Uninterruptible power supply (UPS)
units for control cabinets
IQ technology is the key to an intelligent
power supply solution. The UPS monitors
and optimizes the power storage device.
Avoid interruptions when working with the
intelligent UPS for non-stop power.

Redundancy modules

204

QUINT ORING

206

TRIO DIODE

208

QUINT DIODE

210

STEP DIODE

210

Uninterruptible power supply (UPS)
for 19" racks/towers
Protect all connected loads against any
faults on the mains side with the singlephase VFl-SS-111 UPS devices.

Accessories

212

Uninterruptible power supply units for the control cabinet
Selection guide

214

QUINT UPS-IQ

218

Power storage device for QUINT UPS-IQ

222

Accessories

228

UPS module with integrated power storage

230

UPS module with integrated power supply unit

234

Power storage devices for TRIO UPS and MINI UPS

236

Uninterruptible power supply units for 19" racks/towers

240

Selection guide

242

UPS devices

244

Power storage

246

Accessories

248

DC/DC converter
Change the voltage level, regenerate the
voltage at the end of long cables or enable
the creation of independent supply systems
with the QUINT and MINI DC/DC converters.
Redundancy modules
A redundant power supply system is the
result of the parallel connection of two
power supply units. Optimize this solution
with the QUINT ORING redundancy modules and the QUINT, TRIO, and STEP diodes for maximum system availability.

216

PHOENIX CONTACT

159

Power supply units and UPS
Selection guide
QUINT POWER 1∼

24 DC / 3.5 A

24 DC / 5 A

24 DC / 10 A

24 DC / 20 A

24 DC / 40 A

Page 166

Page 166

Page 166

Page 166

Page 166

12 DC / 15 A

12 DC / 20 A

Page 170

Page 170

48 DC / 5 A

48 DC / 10 A

48 DC / 20 A

Page 170

Page 170

Page 170

24 DC / 40 A

QUINT POWER 3∼

24 DC / 5 A

24 DC / 10 A

24 DC / 20 A

Page 168

Page 168

Page 168

Page 168

48 DC / 20 A
Page 172

TRIO POWER 1∼

24 DC / 2.5 A

24 DC / 5 A

24 DC / 10 A

Page 174

Page 174

Page 174

24 DC / 20 A
Page 174

12 DC / 5 A

12 DC / 10 A

48 DC / 5 A

48 DC / 10 A

Page 178

Page 178

Page 178

Page 178

24 DC / 5 A

24 DC / 10 A

24 DC / 20 A

24 DC / 40 A

Page 176

Page 176

Page 176

Page 176

24 DC / 1.3 A

24 DC / 1.5 A

24 DC / 2 A

24 DC / 4 A

1 AC / 24 DC / 1.5 A EX

Page 180

Page 180

Page 180

Page 180

Page 194

10 - 15 DC / 2 A

24 DC / 100 W

TRIO POWER 3∼

MINI POWER 1∼

5 DC / 3 A
Page 182

160

PHOENIX CONTACT

Page 182

Page 180

±15 DC / 1 A

10 - 15 DC / 8 A

Page 182

Page 182

Power supply units and UPS
Selection guide
UNO POWER 1∼

24 DC / 30 W

24 DC / 60 W

24 DC / 100 W

Page 184

Page 184

Page 184

12 DC / 30 W

12 DC / 55 W

Page 184

Page 184

STEP POWER 1∼

24 DC / 0.5 A

24 DC / 0.75 A / FL

24 DC / 0.75 A

24 DC / 1.75 A

24 DC / 2.5 A

Page 186

Page 186

Page 186

Page 188

Page 188

24 DC / 4.2 A
Page 188

48 AC / 24 DC / 0.5 A

12 DC / 1.5 A / FL

12 DC / 1.5 A

12 DC / 3 A

5 DC / 6.5 A

24 DC / 100 W

Page 186

Page 192

Page 192

Page 192

Page 190

Page 2868667

12 DC / 1 A

12 DC / 5 A

48 DC / 2 A

Page 192

Page 192

Page 190

5 DC / 2 A

15 DC / 4 A

Page 190

Page 190

QUINT POWER, dip-coated 1∼, 3∼ power supply units

1 AC / 24 DC / 5 A CO

QUINT DC/DC converters

1 AC / 24 DC / 10 A CO 1 AC / 24 DC / 20 A CO 3 AC / 24 DC / 20 A CO 24 DC / 24 DC / 5 A / 24 DC / 24 DC / 10 A / 24 DC / 24 DC / 20 A /

Page 194

Page 194

Page 194

Page 194

QUINT DC/DC converters

24 DC / 24 DC / 5 A

Page 200

MINI DC/DC converters

24 DC / 24 DC / 10 A 24 DC / 24 DC / 20 A 12 - 24 DC/24 DC/1 A

Page 198

Page 198

24 DC / 12 DC / 8 A

24 DC / 48 DC / 5 A

Page 198

Page 198

Page 198

Page 202

Page 200

Page 200

TRIO POWER 600 V

AC power module

600 DC / 24 DC / 20 A

Page 202

Page 178

48 - 60 DC/24 DC/1 A
Page 202

48 DC / 24 DC / 5 A

12 - 24 DC/5 - 15 DC/2 A

Page 200

Page 202

12 DC / 24 DC / 5 A

12 - 24 D /48 DC/0.7 A

Page 200

Page 202

Redundancy modules - QUINT

- TRIO

- STEP

24 DC / 2x10 A

24 DC / 2x20 A

24 DC / 2x40

12 - 24 DC / 2x20 A

12 - 24 DC / 2x10 A

5 - 24 DC / 2x5 A

Page 206

Page 206

Page 206

Page 210

Page 208

Page 210

48 DC / 2x20 A

48 DC / 2x10 A

Page 210

Page 208

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

161

Power supply units and UPS
Selection guide
QUINT DC-UPS

QUINT AC-UPS

24 DC / 5 A

24 DC / 10 A

24 DC / 20 A

24 DC / 40 A

12 DC / 5 / 24 DC / 10

1 AC / 1 AC / 500 VA

Page 218

Page 218

Page 218

Page 218

Page 220

Page 221

UPS-CAP

UPS-BAT/LI-ION

UPS-BAT/VRLA-WTR

24 DC / 10 A / 10 KJ

24 DC / 20 A / 20 KJ

24 DC / 120 WH

24 DC / 13 AH

24 DC / 26 AH

Page 222

Page 222

Page 223

Page 226

Page 226

24DC / 1.3AH

24DC / 3.4AH

24 DC / 7.2 AH

24 DC / 12 AH

24 DC / 38 AH

Page 224

Page 224

Page 224

Page 224

Page 224

UPS-BAT/VRLA

UPS with integrated QUINT, STEP power storage

QUINT-BUFFER

24DC / 5 / 1.3AH

24DC /10 / 3.4AH AH

24 DC / 3

12 DC / 4

24 DC / 40

Page 230

Page 230

Page 232

Page 232

Page 231

UPS with integrated power supply unit

1AC / 24 DC / 2

1AC / 12 DC / 4

1 AC / 24 DC / 5

Page 235

Page 235

Page 234

162

PHOENIX CONTACT

Power supply units and UPS
Selection guide
Power storage for TRIO UPS

- MINI UPS

24 DC / 1.3 AH

24 DC / 3.4 AH

24 DC / 7.2 AH

24 DC / 12 AH

24 DC / 1.3 AH

Page 236

Page 236

Page 236

Page 236

Page 238

24 DC / 0.8 AH
Page 238

12 DC / 2.6 AH

12 DC / 1.6 AH

Page 238

Page 238

USV-CP

1 kVA / 240 AC

2 kVA / 240 AC

3 kVA / 240 AC

4.5 kVA / 240 AC

6 kVA / 240 AC

Page 244

Page 244

Page 244

Page 244

Page 244

1 kVA / 19 minutes

1 kVA / 36 minutes

2/3 kVA / 8 minutes

Page 246
For UPS-CP-1KVA

Page 246
For UPS-CP-1KVA

Page 246
For UPS-CP-2KVA

Page 246
For UPS-CP-2KVA

Page 246
For UPS-CP-4.5KVA

2/3 kVA / 5 minutes

2/3 kVA / 12 minutes

2/3 kVA / 8 minutes

Page 246
For UPS-CP-3KVA

Page 246
For UPS-CP-3KVA

Page 246
For UPS-CP-6KVA

Power storage for USV-CP

2/3 kVA / 19 minutes 4.5/6 kVA / 10 minutes

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

163

Power supply units and UPS
Power supply units

Leading technology and high quality power supply units ensure your system is always reliably supplied with
power.
Thanks to high-quality products featuring
leading technology, with our power supply
solutions from the QUINT, TRIO, MINI, and
STEP product ranges, you are optimally
equipped to handle competitors on an international scale.
Functionality, performance class, and design are tailored to the demands of various
different sectors and always offer the ideal
solution. Choose from our wide range of
power supply units and DC/DC converters.

QUINT POWER for maximum system availability
Cost-effective selective fuse protection
with SFB technology:
In order to trip standard circuit breakers
magnetically and quickly, power supply units
must be able to supply several times the
nominal current for a short period. With
SFB (Selective Fuse Breaking) technology,
which supplies up to 6 times the nominal
current for 12 ms, a dynamic power reserve
is available. Faulty current paths are selectively switched off, the fault is isolated, and
important system components remain operational.
Preventive function monitoring:
Comprehensive diagnostics are provided
through constant monitoring of the output
voltage and output current. This preventive
function monitoring visualizes critical operating states, before errors can occur. The
remote monitoring takes place by means of
active switching outputs and floating relay
contacts.

164

PHOENIX CONTACT

POWER BOOST power reserve:
The static power reserve offers up to 1.5
times the nominal current permanently. At
ambient temperatures of up to +40°C the
POWER BOOST is continuously available
and at higher temperatures, it is available for
a few minutes. This ensures that both high
inrush currents of capacitive loads, as well as
loads with DC/DC converters in the primary circuit, can be reliably supplied.

Power supply units and UPS
Power supply units

Power supply units - a comparison of
the advantages
Choose the range of power supply units
that best suits your requirements based on
① functionality and ② power.

QUINT POWER – power supply units
for maximum system availability
The unique SFB technology and preventive function monitoring maximize the availability of your application.
– Quick tripping of the standard power circuit breakers
– Preventive function monitoring
– Reliable starting of heavy loads

TRIO POWER - basic functionality at
the highest level
Basic functionality combined with high
quality and reliability - this makes the power
supply units ideal for use in standard machine production.
– Robust design
– Minimize installation costs
– High operational reliability

UNO POWER - compact basic
functionality
The UNO POWER power supply units
offer extremely compact basic functionality.
– Save energy thanks to high efficiency and
low idling losses
– Wide-range input
– Wide temperature range

MINI POWER - for measurement and
control technology
The MINI POWER comes into its own in
fields where modular electronics housing
has become the standard.
– Service-friendly connection technology:
encoded COMBICON plug-in connectors
– Active function monitoring with switching
output for remote monitoring of the output voltage

STEP POWER - for installation
distributors and flat control panels
The low idling losses and high efficiency
make the STEP POWER the most energy
efficient in its class.
– Flexible: snap onto the DIN rail or screw
onto a level surface
– Energy savings: maximum energy efficiency and incredibly low idling losses

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

165

Power supply units and UPS
Power supply units
QUINT POWER power supply units –
for maximum system availability
– Quick tripping of standard circuit breakers thanks to the dynamic power reserve
SFB (selective fuse breaking) technology
with up to 6x the nominal current for
12 ms
– Reliable starting of heavy loads with the
static POWER BOOST power reserve
with permanently up to 1.5 times the
nominal current
– Preventive function monitoring warns
against critical operating states before errors occur
– Approved according to SEMI F47:
all 24 V DC

H

H
W

D

D

W

Power supply,
1 AC, 24 V DC, 3.5 A

Power supply,
1 AC, 24 V DC, 5 A


Ex: 


Ex: 

L (+)

L (+)

N (-)

N (-)

active

PFC

DC OK
I < IN

DC OK
I < IN

13

13

14

14

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
1.4 A (120 V AC) / 0.8 A (230 V AC)
< 20 A / < 2 A2s
> 20 ms (120 V AC) / > 80 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
1.2 A (120 V AC) / 0.6 A (230 V AC)
< 15 A / < 1 A2s
> 30 ms (120 V AC) / > 30 ms (230 V AC)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

Output current / POWER BOOST / SFB (12 ms)
Magnetic fuse tripping

3.5 A / 4 A / 15 A
B2

5 A / 7.5 A / 30 A
B2 , B4 , C2

Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
Boost signaling
General data
Weight / Dimensions W x H x D
Spacing when mounting

Yes / Yes
3.5 W / 11 W
> 88 % (for 230 V AC and nominal values)
< 50 mVPP

Yes / Yes
3 W / 15 W
> 90 % (for 230 V AC and nominal values)
< 40 mVPP

LED, active switching output, relay contact
LED, active switching output

LED, active switching output, relay contact
LED, active switching output

0.5 kg / 32 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
IP20 / I
> 820000 h
-25 °C ... 70 °C (> 60 °C derating)

0.7 kg / 40 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
IP20 / I
> 635000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
IEC 60601
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
IEC 60601
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage

Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
Medical standard
UL approvals

Limitation of harmonic line currents

Ordering data
Description

Ordering data

Type

Order No.

QUINT-PS/ 1AC/24DC/ 3.5

2866747

Pcs. /
Pkt.

Type

Order No.

QUINT-PS/ 1AC/24DC/ 5

2866750

Pcs. /
Pkt.

Power supply unit, primary-switched

166

PHOENIX CONTACT

1

1

Power supply units and UPS
Power supply units
H
D

H
W

D

H
W

D

W

Power supply,
1 AC, 24 V DC, 10 A

Power supply,
1 AC, 24 V DC, 20 A

Power supply,
1 AC, 24 V DC, 40 A

     BSH           
Ex: 

     BSH          
Ex: 

            BV-CPS  
Ex: 

L (+)

L (+)

L (+)
active

active

N (-)

PFC

N (-)

active

PFC

N (-)

PFC

DC OK
I < IN

DC OK
I < IN

DC OK
I < IN

13

13

13

14

14

14

Technical data

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
2.24 A (120 V AC) / 1.33 A (230 V AC)
< 15 A / < 1.5 A2s
> 32 ms (120 V AC) / > 36 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
5.1 A (120 V AC) / 2.3 A (230 V AC)
< 20 A / < 3.2 A2s
> 20 ms (120 V AC) / > 20 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 300 V DC
45 Hz ... 65 Hz / 0 Hz
8.8 A (120 V AC) / 4.6 A (230 V AC)
< 15 A / < 1.7 A2s
> 20 ms (120 V AC) / > 20 ms (230 V AC)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

10 A / 15 A / 60 A
B2 , B4 , B6 , C2 , C4

20 A / 26 A / 120 A
B2 , B4 , B6 , B10 , B16 , C2 , C4 , C6

40 A / 45 A / 215 A
B2 , B4 , B6 , B10 , B16 , B25 , C2 , C4 , C6 , C13

Yes / Yes
9.1 W / 22 W
> 92.5 % (for 230 V AC and nominal values)
< 50 mVPP

Yes / Yes
8 W / 40 W
> 93 % (for 230 V AC and nominal values)
< 30 mVPP

Yes / Yes
14 W / 80 W
> 92 % (for 230 V AC and nominal values)
< 30 mVPP

LED, active switching output, relay contact
LED, active switching output

LED, active switching output, relay contact
LED, active switching output

LED, active switching output, relay contact
LED, active switching output

1.1 kg / 60 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
IP20 / I
> 535000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

1.7 kg / 90 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
IP20 / I
> 520000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

3.3 kg / 180 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 14 - 10
0.5 - 16 mm² / 0.5 - 16 mm² / 8 - 6
0.2 - 6 mm² / 0.2 - 4 mm² / 24 - 10
IP20 / I
> 530000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
IEC 60601
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
IEC 60601
UL Listed UL 508 , UL/C-UL Recognized UL 60950 , UL ANSI/ISA12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
EN 61000-3-2

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-101
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

QUINT-PS/ 1AC/24DC/10

2866763

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

QUINT-PS/ 1AC/24DC/20

2866776

Pcs. /
Pkt.

1

Type

Order No.

QUINT-PS/ 1AC/24DC/40

2866789

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

167

Power supply units and UPS
Power supply units
QUINT POWER power supply units –
for maximum system availability

H
D

QUINT POWER, 3 AC, 24 V DC
– High system availability even in the event
of a permanent phase failure
– High surge strength of up to 6 kV thanks
to integrated gas-filled arresters
– Quick tripping of standard circuit breakers thanks to the dynamic power reserve
SFB (selective fuse breaking) technology
with up to 6x the nominal current for
12 ms
– Reliable starting of heavy loads with the
static POWER BOOST power reserve
with permanently up to 1.5 times the
nominal current
– Preventive function monitoring warns
against critical operating states before errors occur
– Approved according to SEMI F47:
all 24 V DC

W

Power supply,
3 AC, 24 V DC, 5 A


Ex: 

L1 (+)
L2
L3 (-)

DC OK
I < IN
13
14

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage

3x 400 V AC ... 500 V AC
320 V AC ... 575 V AC / 450 V DC ... 800 V DC
45 Hz ... 65 Hz / 0 Hz
3x 0.8 A (400 V AC) / 3x 0.7 A (500 V AC)
< 15 A / < 1 A2s
> 20 ms (400 V AC) / > 30 ms (500 V AC)
24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

Output current / POWER BOOST / SFB (12 ms)
Magnetic fuse tripping

5 A / 7.5 A / 30 A
B2 , B4 , C2

Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
Boost signaling
General data
Weight / Dimensions W x H x D
Spacing when mounting

Yes / Yes
4 W / 14 W
> 89 % (at 400 V AC and nominal values)
< 20 mVPP

Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals

Limitation of harmonic line currents

LED, active switching output, relay contact
LED, active switching output
0.7 kg / 40 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
IP20 / I
> 635000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL Listed UL 508 , UL/C-UL Recognized UL 60950 (3-wire + PE,
star net) , UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C,
D (Hazardous Location)
EN 61000-3-2

Ordering data
Description

Type

Order No.

QUINT-PS/ 3AC/24DC/ 5

2866734

Pcs. /
Pkt.

Power supply unit, primary-switched

168

PHOENIX CONTACT

1

Power supply units and UPS
Power supply units
H
D

H
W

D

H
W

D

Power supply,
3 AC, 24 V DC, 10 A

Power supply,
3 AC, 24 V DC, 20 A

     BSH         
Ex: 

     BSH          
Ex: 

Ex: 

L1 (+)

L1 (+)

L1 (+)

L2

L2

L2

L3 (-)

L3 (-)

L3 (-)

DC OK
I < IN

W

Power supply,
3 AC, 24 V DC, 40 A



DC OK
I < IN

DC OK
I < IN

13

13

13

14

14

14

Technical data

Technical data

Technical data

3x 400 V AC ... 500 V AC
320 V AC ... 575 V AC / 450 V DC ... 800 V DC
45 Hz ... 65 Hz / 0 Hz
3x 1.2 A (400 V AC) / 3x 1 A (500 V AC)
< 15 A / < 1.5 A2s
> 20 ms (400 V AC) / > 30 ms (500 V AC)

3x 400 V AC ... 500 V AC
320 V AC ... 575 V AC / 450 V DC ... 800 V DC
45 Hz ... 65 Hz / 0 Hz
3x 1.6 A (400 V AC) / 3x 1.3 A (500 V AC)
< 20 A / < 3.2 A2s
> 20 ms (400 V AC) / > 30 ms (500 V AC)

3x 400 V AC ... 500 V AC
320 V AC ... 575 V AC / 450 V DC ... 800 V DC
45 Hz ... 65 Hz / 0 Hz
3x 2.1 A (400 V AC) / 3x 1.7 A (500 V AC)
< 20 A / < 1 A2s
> 25 ms (400 V AC) / > 35 ms (500 V AC)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

10 A / 15 A / 60 A
B2 , B4 , B6 , C2 , C4

20 A / 26 A / 120 A
B2 , B4 , B6 , B10 , B16 , C2 , C4 , C6

40 A / 45 A / 215 A
B2 , B4 , B6 , B10 , B16 , B25 , C2 , C4 , C6 , C13

Yes / Yes
7 W / 19 W
> 93 % (at 400 V AC and nominal values)
< 20 mVPP

Yes / Yes
11 W / 40 W
> 93 % (at 400 V AC and nominal values)
< 40 mVPP

Yes / Yes
18 W / 63 W
> 94 % (at 400 V AC and nominal values)
< 40 mVPP

LED, active switching output, relay contact
LED, active switching output

LED, active switching output, relay contact
LED, active switching output

LED, active switching output, relay contact
LED, active switching output

1.1 kg / 60 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
IP20 / I
> 633000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

1.5 kg / 69 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
IP20 / I
> 534000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

2.5 kg / 96 x 130 x 176 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
0.5 - 16 mm² / 0.5 - 16 mm² / 8 - 6
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
IP20 / I
> 501000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL Listed UL 508 , UL/C-UL Recognized UL 60950 (3-wire + PE,
star net) , UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C,
D (Hazardous Location)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL Listed UL 508 , UL/C-UL Recognized UL 60950 (3-wire + PE,
star net) , UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C,
D (Hazardous Location)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-101
UL Listed UL 508 , UL/C-UL Recognized UL 60950 (3-wire + PE,
star net) , UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C,
D (Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

QUINT-PS/ 3AC/24DC/10

2866705

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

QUINT-PS/ 3AC/24DC/20

2866792

Pcs. /
Pkt.

1

Type

Order No.

QUINT-PS/ 3AC/24DC/40

2866802

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

169

Power supply units and UPS
Power supply units
QUINT POWER power supply units –
for maximum system availability
QUINT POWER, 1 AC, 12 and
48 V DC
– Quick tripping of the standard power
circuit breakers
– Reliable starting of heavy loads
– Preventive function monitoring
– Approved according to SEMI F47: 12 V
DC, 15 A A and 20 A, 48 V DC, 5 A and
10 A
– Adjustable output voltage of 5 to
18 V DC, or 30 to 56 V DC

H

H
D

W

D

Power supply,
1 AC, 12 V DC, 15 A

Power supply,
1 AC, 12 V DC, 20 A




Ex: 

L (+)

L (+)

Ex: 

active

active

N (-)

Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage
Output current / POWER BOOST / SFB (12 ms)
Magnetic fuse tripping
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
Boost signaling
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
Medical standard
UL approvals

Limitation of harmonic line currents

PFC

N (-)

PFC

DC OK
I < IN

DC OK
I < IN

13

13

14

14

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
1.9 A (120 V AC) / 0.9 A (230 V AC)
< 15 A / < 1.5 A2s
> 65 ms (120 V AC) / > 65 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
2.4 A (120 V AC) / 1.4 A (230 V AC)
< 20 A / < 3.2 A2s
> 40 ms (120 V AC) / > 40 ms (230 V AC)

12 V DC ±1%
5 V DC ... 18 V DC (> 12 V constant capacity)

12 V DC ±1%
5 V DC ... 18 V DC (> 12 V constant capacity)

15 A / 16 A / 60 A
B2 , B4 , B6 , C2 , C4
Yes / Yes
5 W / 21 W
> 89 % (for 230 V AC and nominal values)
< 10 mVPP

20 A / 26 A / 120 A
B2 , B4 , B6 , B10 , C2 , C4 , C6
Yes / Yes
6 W / 29 W
> 90 % (for 230 V AC and nominal values)
< 50 mVPP

LED, active switching output, relay contact
LED, active switching output

LED, active switching output, relay contact
LED, active switching output

1.1 kg / 60 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
IP20 / I
> 570000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

1.5 kg / 90 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
IP20 / I
> 600000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
IEC 60601
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
IEC 60601
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Ordering data
Description

W

Ordering data

Type

Order No.

QUINT-PS/ 1AC/12DC/15

2866718

Pcs. /
Pkt.

Type

Order No.

QUINT-PS/ 1AC/12DC/20

2866721

Pcs. /
Pkt.

Power supply unit, primary-switched

170

PHOENIX CONTACT

1

1

Power supply units and UPS
Power supply units
H
D

H
W

D

Power supply,
1 AC, 48 V DC, 5 A

H
W

D

W

Power supply,
1 AC, 48 V DC, 10 A

Power supply,
1 AC, 48 V DC, 20 A


Ex: 


Ex: 


Ex: 

L (+)

L (+)

L (+)
active

active

N (-)

PFC

N (-)

active

PFC

N (-)

PFC

DC OK
I < IN

DC OK
I < IN

DC OK
I < IN

13

13

13

14

14

14

Technical data

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
2.8 A (120 V AC) / 1.2 A (230 V AC)
< 15 A / < 1.5 A2s
> 40 ms (120 V AC) / > 40 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
5.1 A (120 V AC) / 2.3 A (230 V AC)
< 20 A / < 3.2 A2s
> 20 ms (120 V AC) / > 20 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 300 V DC
45 Hz ... 65 Hz / 0 Hz
8.7 A (120 V AC) / 4.5 A (230 V AC)
< 15 A / < 1.6 A2s
> 22 ms (120 V AC) / > 25 ms (230 V AC)

48 V DC ±1%
30 V DC ... 56 V DC (> 48 V constant capacity)

48 V DC ±1%
30 V DC ... 56 V DC (> 48 V constant capacity)

48 V DC ±1%
30 V DC ... 56 V DC (> 48 V constant capacity)

5 A / 7.5 A / 30 A
B2 , B4 , C2
Yes / Yes
7 W / 21 W
> 92.5 % (for 230 V AC and nominal values)
< 50 mVPP

10 A / 13 A / 60 A
B2 , B4 , B6 , C2 , C4
Yes / Yes
16 W / 41 W
> 93 % (for 230 V AC and nominal values)
< 80 mVPP

20 A / 22.5 A / 100 A
B2 , B4 , B6 , B10 , C2 , C4 , C6
Yes / Yes
12 W / 74 W
> 93 % (for 230 V AC and nominal values)
< 50 mVPP

LED, active switching output, relay contact
LED, active switching output

LED, active switching output, relay contact
LED, active switching output

LED, active switching output, relay contact
LED, active switching output

1.1 kg / 60 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
IP20 / I
> 535000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

1.7 kg / 90 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
IP20 / I
> 630000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

3.3 kg / 180 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 14 - 10
0.5 - 16 mm² / 0.5 - 16 mm² / 8 - 6
0.2 - 6 mm² / 0.2 - 4 mm² / 24 - 10
IP20 / I
> 523000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
IEC 60601
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
IEC 60601
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

QUINT-PS/ 1AC/48DC/ 5

2866679

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

QUINT-PS/ 1AC/48DC/10

2866682

Pcs. /
Pkt.

1

Type

Order No.

QUINT-PS/ 1AC/48DC/20

2866695

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

171

Power supply units and UPS
Power supply units
QUINT POWER power supply units –
for maximum system availability

H
D

QUINT POWER, 3 AC, 48 V DC
– Quick tripping of standard circuit breakers thanks to the dynamic power reserve
SFB (selective fuse breaking) technology
with up to 6x the nominal current for
12 ms
– Reliable starting of heavy loads with the
static POWER BOOST power reserve
with permanently up to 1.5 times the
nominal current
– Preventive function monitoring warns
against critical operating states before errors occur
– Adjustable output voltage of 30 to
56 V DC

W

Power supply,
3 AC, 48 V DC, 20 A


Ex: 

L1 (+)
L2
L3 (-)

DC OK
I < IN
13
14

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage
Output current / POWER BOOST / SFB (12 ms)
Magnetic fuse tripping
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
Boost signaling
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals

Limitation of harmonic line currents

3x 400 V AC ... 500 V AC
320 V AC ... 575 V AC / 450 V DC ... 800 V DC
45 Hz ... 65 Hz / 0 Hz
3x 2.1 A (400 V AC) / 3x 1.7 A (500 V AC)
< 20 A / < 1 A2s
> 25 ms (400 V AC) / > 35 ms (500 V AC)
48 V DC ±1%
30 V DC ... 56 V DC (> 48 V constant capacity)
20 A / 22.5 A / 100 A
B2 , B4 , B4 , B10 , C2 , C4 , C6
Yes / Yes
24 W / 70 W
> 93 % (at 400 V AC and nominal values)
< 50 mVPP
LED, active switching output, relay contact
LED, active switching output
2.5 kg / 96 x 130 x 176 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
0.5 - 16 mm² / 0.5 - 16 mm² / 8 - 6
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
IP20 / I
> 509000 h
-25 °C ... 70 °C (> 60°C derating, startup at -40°C type-tested)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Ordering data
Description

Type

Order No.

QUINT-PS/ 3AC/48DC/20

2320827

Pcs. /
Pkt.

Power supply unit, primary-switched

172

PHOENIX CONTACT

1

Power supply units and UPS
Power supply units

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

173

Power supply units and UPS
Power supply units
TRIO POWER power supply units –
basic functionality at the highest level

H
D

TRIO POWER, 1 AC, 24 V DC
– Rugged design with metal housing and
wide temperature range of -25 to +70°C
– Third negative terminal block for grounding on the secondary side
– Maximum availability thanks to high MTBF
(Mean Time Between Failures) of more
than 500,000 hours and high dielectric
strength of up to 300 V AC
– Compensation of voltage drops by means
of output voltage of 22.5 to 29.5 V DC
that can be adjusted on the front

W

Power supply,
1 AC, 24 V DC, 2.5 A



L

N

PE

Technical data
Input data
Nominal input voltage range
Input voltage range AC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage
Output current
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals
Limitation of harmonic line currents

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
0.95 A (120 V AC) / 0.5 A (230 V AC)
< 15 A / 0.5 A2s
> 20 ms (120 V AC) / > 100 ms (230 V AC)
24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)
2.5 A
Yes / Yes
0.8 W / 10 W
> 86 % (for 230 V AC and nominal values)
< 30 mVPP
LED
0.5 kg / 32 x 130 x 115 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / I, with PE connection
> 2054000 h
-25 °C ... 70 °C (> 55° C derating)
2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950
EN 61000-3-2

Ordering data
Description

Type

Order No.

TRIO-PS/ 1AC/24DC/ 2.5

2866268

Pcs. /
Pkt.

Power supply unit, primary-switched

174

PHOENIX CONTACT

1

Power supply units and UPS
Power supply units
H
D

H
W

H
W

D

Power supply,
1 AC, 24 V DC, 5 A

D

W

Power supply,
1 AC, 24 V DC, 10 A





L

L

Power supply,
1 AC, 24 V DC, 20 A



L
active

N

N

PE

PE

active

PFC

N

PFC

PE

Technical data

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
1.65 A (120 V AC) / 0.9 A (230 V AC)
< 15 A / 1.1 A2s
> 20 ms (120 V AC) / > 110 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
3 A (100 V AC) / 1.5 A (240 V AC)
< 15 A / 0.7 A2s
> 24 ms (120 V AC) / > 24 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
4.6 A (120 V AC) / 2.4 A (230 V AC)
< 15 A / 1.4 A2s
> 13 ms (120 V AC) / > 13 ms (230 V AC)

24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)

5A
Yes / Yes
1.1 W / 18 W
> 89 % (for 230 V AC and nominal values)
< 20 mVPP

10 A
Yes / Yes
6.7 W / 30 W
> 89 % (for 230 V AC and nominal values)
< 10 mVPP

20 A
Yes / Yes
4 W / 46 W
> 91 % (for 230 V AC and nominal values)
< 10 mVPP

LED

LED

LED

0.6 kg / 40 x 130 x 115 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / I, with PE connection
> 2031000 h
-25 °C ... 70 °C (> 55° C derating)

1.4 kg / 60 x 130 x 152.5 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / I, with PE connection
> 981000 h
-25 °C ... 70 °C (> 55° C derating)

2.2 kg / 115 x 130 x 152.5 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.5 - 6 mm² / 0.5 - 4 mm² / 20 - 10
IP20 / I, with PE connection
> 915000 h
-25 °C ... 70 °C (> 55° C derating)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

TRIO-PS/ 1AC/24DC/ 5

2866310

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

TRIO-PS/ 1AC/24DC/10

2866323

Pcs. /
Pkt.

1

Type

Order No.

TRIO-PS/ 1AC/24DC/20

2866381

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

175

Power supply units and UPS
Power supply units
TRIO POWER power supply units –
basic functionality at the highest level

H
D

TRIO POWER, 3 AC, 24 V DC
– Rugged design with metal housing and
wide temperature range of -25 to +70°C
– Third negative terminal block for grounding on the secondary side
– Maximum availability thanks to high MTBF
(Mean Time Between Failures) of more
than 500,000 hours
– Compensation of voltage drops by means
of output voltage of 22.5 to 29.5 V DC
that can be adjusted on the front

W

Power supply,
3 AC, 24 V DC, 5 A



L1
L2
(L3)
PE

Technical data
Input data
Nominal input voltage range
Input voltage range AC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage
Output current
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals
Limitation of harmonic line currents

2x / 3x 400 V AC ... 500 V AC
320 V AC ... 575 V AC
45 Hz ... 65 Hz
3x 0.3 A (400 V AC) / 3x 0.25 A (500 V AC)
< 15 A / 0.2 A2s
> 20 ms (400 V AC) / > 30 ms (480 V AC)
24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)
5A
Yes / Yes
4 W / 15 W
> 89 % (at 400 V AC and nominal values)
< 30 mVPP
LED
0.6 kg / 40 x 130 x 115 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
IP20 / I, with PE connection
> 1474000 h
-25 °C ... 70 °C (> 55° C derating)
2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950
EN 61000-3-2

Ordering data
Description

Type

Order No.

TRIO-PS/ 3AC/24DC/ 5

2866462

Pcs. /
Pkt.

Power supply unit, primary-switched

176

PHOENIX CONTACT

1

Power supply units and UPS
Power supply units
H
D

H
W

H
W

D

Power supply,
3 AC, 24 V DC, 10 A

D

W

Power supply,
3 AC, 24 V DC, 20 A

Power supply unit,
3 AC, 24 V DC, 40 A







L1

L1

L1

L2

L2

L2

(L3)

L3

L3

PE

PE

PE

Technical data

Technical data

Technical data

2x / 3x 400 V AC ... 500 V AC
320 V AC ... 575 V AC
45 Hz ... 65 Hz
3x 0.6 A (400 V AC) / 3x 0.5 A (480 V AC)
< 15 A / 0.2 A2s
> 20 ms (400 V AC) / > 25 ms (480 V AC)

3x 400 V AC ... 500 V AC
320 V AC ... 575 V AC
45 Hz ... 65 Hz
3x 1.1 A (400 V AC) / 3x 0.8 A (480 V AC)
< 15 A / 0.5 A2s
> 17 ms (400 V AC) / > 20 ms (480 V AC)

3x 400 V AC ... 500 V AC
320 V AC ... 575 V AC
45 Hz ... 65 Hz
3x 2 A (400 V AC) / 3x 1.6 A (480 V AC)
< 20 A / 1.3 A2s
> 16 ms (400 V AC) / > 20 ms (480 V AC)

24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)

10 A
Yes / Yes
6 W / 28 W
> 89 % (at 400 V AC and nominal values)
< 10 mVPP

20 A
Yes / Yes
< 6 W / < 48 W
> 91 % (at 400 V AC and nominal values)
< 10 mVPP

40 A
Yes / Yes
16 W / 91 W
> 91.5 % (at 400 V AC and nominal values)
< 20 mVPP

LED

LED

LED

1.3 kg / 60 x 130 x 152.5 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
IP20 / I, with PE connection
> 1156000 h
-25 °C ... 70 °C (> 55° C derating)

2 kg / 115 x 130 x 152.5 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.5 - 6 mm² / 0.5 - 4 mm² / 12 - 10
IP20 / I, with PE connection
> 1190000 h
-25 °C ... 70 °C (> 55° C derating)

2.9 kg / 139 x 130 x 190 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 22 - 10
0.5 - 16 mm² / 0.5 - 10 mm² / 8 - 6
IP20 / I, with PE connection
> 930000 h
-25 °C ... 70 °C (> 55° C derating)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

TRIO-PS/ 3AC/24DC/10

2866459

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

TRIO-PS/ 3AC/24DC/20

2866394

Pcs. /
Pkt.

1

Type

Order No.

TRIO-PS/ 3AC/24DC/40

2866404

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

177

Power supply units and UPS
Power supply units
TRIO POWER power supply units –
basic functionality at the highest level
TRIO POWER, 600 V DC, 24 V DC
– Connection to 600 V DC intermediate
circuits of frequency inverters: in the
event of a line supply failure, 24 V loads
are supplied using the kinetic energy of
the motor. In this way, the motor acts as
a generator and supplies energy to the
intermediate circuits (e.g., in plastic injection molding machines).
TRIO POWER, 1 AC, 12 V DC and
48 V DC
– Adjustable output voltage of 10 to
18 V DC, or 30 to 56 V DC

H

H
D

W

D

W

Power supply,
600 V DC, 24 V DC, 20 A

Power supply,
1 AC, 12 V DC, 5 A





L

N

PE

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage
Output current
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals
Limitation of harmonic line currents

Technical data

600 V DC
- / 450 V DC ... 840 V DC
- / 0 Hz
0.9 A (600 V DC)
< 26 A / 0.8 A2s
> 15 ms (600 V DC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
1.1 A (100 V AC) / 0.5 A (240 V AC)
< 15 A / < 0.5 A2s
> 26 ms (120 V AC) / > 100 ms (230 V AC)

24 V DC ±1%
22.5 V DC ... 29.5 V DC (UIN > 475 V DC)
22.5 V DC ... 28 V DC (UIN ≤ 475 V DC)
20 A
Yes / Yes
3.8 W / 45 W
> 91 % (With 600 V DC and nominal values)
< 40 mVPP

12 V DC ±1%
10 V DC ... 18 V DC (> 12 V constant capacity)
5A
Yes / Yes
0.9 W / 11 W
> 83 % (for 230 V AC and nominal values)
< 20 mVPP

LED

LED

2 kg / 115 x 130 x 152.5 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.5 - 6 mm² / 0.5 - 4 mm² / 12 - 10
IP20 / I, with PE connection
> 701147 h
-25 °C ... 70 °C (> 55° C derating)

0.5 kg / 32 x 130 x 115 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / I, with PE connection
> 1853000 h
-25 °C ... 70 °C (> 55° C derating)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

EN 61000-3-2

EN 61000-3-2

Ordering data
Description

Ordering data

Type

Order No.

TRIO-PS/600DC/24DC/20

2866530

Pcs. /
Pkt.

Type

Order No.

TRIO-PS/ 1AC/12DC/ 5

2866475

Pcs. /
Pkt.

Power supply unit, primary-switched

178

PHOENIX CONTACT

1

1

Power supply units and UPS
Power supply units
H
D

H
W

H
W

D

Power supply,
1 AC, 12 V DC, 10 A

D

W

Power supply,
1 AC, 48 V DC, 5 A



Power supply,
1 AC, 48 V DC, 10 A



L



L

L
active

active

PFC

N

N

N

PE

PFC

PE

Technical data

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
1.7 A (120 V AC) / 0.9 A (230 V AC)
< 15 A / < 1.1 A2s
> 20 ms (120 V AC) / > 86 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
2.5 A (120 V AC) / 1.3 A (230 V AC)
< 15 A / < 0.7 A2s
> 15 ms (120 V AC) / > 16 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
4.6 A (120 V AC) / 2.4 A (230 V AC)
< 15 A / < 1.4 A2s
> 13 ms (120 V AC) / > 18 ms (230 V AC)

12 V DC ±1%
10 V DC ... 18 V DC (> 12 V constant capacity)

48 V DC ±1%
30 V DC ... 56 V DC (> 48 V constant capacity)

48 V DC ±1%
30 V DC ... 56 V DC (> 48 V constant capacity)

10 A
Yes / Yes
1.1 W / 18 W
> 86 % (for 230 V AC and nominal values)
< 20 mVPP

5A
Yes / Yes
7 W / 28 W
> 89 % (for 230 V AC and nominal values)
< 50 mVPP

10 A
Yes / Yes
8 W / 49 W
> 91 % (for 230 V AC and nominal values)
< 50 mVPP

LED

LED

LED

0.6 kg / 40 x 130 x 115 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / I, with PE connection
> 1871000 h
-25 °C ... 70 °C (> 55° C derating)

1.4 kg / 60 x 130 x 152.5 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / I, with PE connection
> 1337000 h
-25 °C ... 70 °C (> 55° C derating)

1.9 kg / 115 x 130 x 152.5 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.5 - 6 mm² / 0.5 - 4 mm² / 20 - 10
IP20 / I, with PE connection
> 1168000 h
-25 °C ... 70 °C (> 55° C derating)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL Listed UL 508 , UL/C-UL Recognized UL 60950

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

TRIO-PS/ 1AC/12DC/10

2866488

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

TRIO-PS/ 1AC/48DC/ 5

2866491

Pcs. /
Pkt.

1

Type

Order No.

TRIO-PS/ 1AC/48DC/10

2866501

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

179

Power supply units and UPS
Power supply units
MINI POWER power supply units - for
measurement and control technology
MINI POWER, 1 AC, 24 V DC
– Easy-to-maintain connection method
thanks to keyed COMBICON connector
– Remote monitoring of output voltage via
switching output
MINI POWER, 1.5 A
– Flat power supply units with a depth of
just 95 mm
– Optional: DIN rail connector for supplying other modules
Per power supply:
2 x ME 17,5 TBUS 1,5/5-ST-3,82 GN
(Order No.: 2709561)
MINI POWER, 100 W
– Output power limited to 100 W: specifically for applications that require certification according to UL 1310/508 Listed
Class 2

H

H
D

W

W

D

Power supply,
1 AC, 24 V DC, 1.3 A

Power supply unit, 1 AC, 24 V DC, 1.5 A,
flat design, optional DIN rail connector


Ex: 



Ex: 

24V

L (+)
L

NC
NC

DC OK

Output current / POWER BOOST
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Connection data solid / stranded / AWG
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals

Limitation of harmonic line currents

24V
13

N

14

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
0.65 A (120 V AC) / 0.25 A (230 V AC)
< 15 A / 0.6 A2s
> 20 ms (120 V AC) / > 110 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
0.75 A (120 V AC) / 0.45 A (230 V AC)
< 15 A / 0.6 A2s
> 35 ms (120 V AC) / > 150 ms (230 V AC)

24 V DC ±1%
22.5 V DC ... 28.5 V DC (> 24 V constant capacity)

24 V DC ±1%
-

1.3 A / 1.6 A
Yes / Yes
0.9 W / 4.5 W
> 85 % (for 230 V AC and nominal values)
< 20 mVPP

1.5 A / 2 A
Yes / No
1.5 W / 6.5 W
> 84 % (for 230 V AC and nominal values)
< 40 mVPP

LED, active switching output

LED, relay contact

0.2 kg / 22.5 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1104000 h
-25 °C ... 70 °C (> 60 °C derating)

0.25 kg / 35 x 99 x 95 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 2789000 h
-25 °C ... 70 °C (> 60 °C derating)

3 kV (Routine test) / 4 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location) , NEC Class 2 as per UL 1310

3 kV (Routine test) / 4 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

Ordering data
Description

0V

N (-)

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage

0V

NC

Type

Ordering data
Order No.

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

Power supply unit, primary-switched
MINI-PS-100-240AC/24DC/1.3

Accessories

2866446

1

MINI-SYS-PS-100-240AC/24DC/1.5

2866983

1

2709561

10

Accessories

DIN rail connector (optional), for routing through the supply voltage and data signal, two pieces are required per device
ME 17,5 TBUS 1,5/ 5-ST-3,81 GN

180

PHOENIX CONTACT

Power supply units and UPS
Power supply units
H
D

H
W

H
W

D

Power supply,
1 AC, 24 V DC, 2 A

D

W

Power supply,
1 AC, 24 V DC, 100 W
NEC Class 2


Ex: 

Power supply,
1 AC, 24 V DC, 4 A


Ex: 

L (+)


Ex: 

L (+)

L (+)

N (-)

N (-)

NC
NC
N (-)
DC OK
DC OK

DC OK

Technical data

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
0.7 A (120 V AC) / 0.4 A (230 V AC)
< 15 A / 4.1 A2s
> 35 ms (120 V AC) / > 170 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
1.3 A (120 V AC) / 0.8 A (230 V AC)
< 15 A / 2.1 A2s
> 20 ms (120 V AC) / > 100 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
1.3 A (120 V AC) / 0.8 A (230 V AC)
< 15 A / 2.1 A2s
> 20 ms (120 V AC) / > 100 ms (230 V AC)

24 V DC ±1%
22.5 V DC ... 28.5 V DC (> 24 V constant capacity)

24 V DC ±1%
22.5 V DC ... 26 V DC (> 24 V constant capacity)

24 V DC ±1%
22.5 V DC ... 28.5 V DC (> 24 V constant capacity)

2 A / 2.9 A
Yes / Yes
2W/7W
> 88 % (for 230 V AC and nominal values)
< 20 mVPP

3.8 A
Yes / Yes
2.5 W / 12 W
> 88 % (for 230 V AC and nominal values)
< 40 mVPP

4A/5A
Yes / Yes
2.5 W / 12 W
> 88 % (for 230 V AC and nominal values)
< 20 mVPP

LED, active switching output

LED, active switching output

LED, active switching output

0.25 kg / 45 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 507981 h
-25 °C ... 70 °C (> 60 °C derating)

0.4 kg / 67.5 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 815000 h
-25 °C ... 70 °C (> 60 °C derating)

0.4 kg / 67.5 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 815000 h
-25 °C ... 70 °C (> 60 °C derating)

3 kV (Routine test) / 4 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location) , NEC Class 2 as per UL 1310

3 kV (Routine test) / 3 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location) , NEC Class 2 as per UL 1310

3 kV (Routine test) / 3 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data
Type

Ordering data
Order No.

MINI-PS-100-240AC/24DC/2

Accessories

2938730

Pcs. /
Pkt.

1

Type

Ordering data
Order No.

MINI-PS-100-240AC/24DC/C2LPS

2866336

Pcs. /
Pkt.

1

Type

Order No.

MINI-PS-100-240AC/24DC/4

Accessories

For additional information, visit www.phoenixcontact.net/products

2938837

Pcs. /
Pkt.

1

Accessories

PHOENIX CONTACT

181

Power supply units and UPS
Power supply units
MINI POWER power supply units - for
measurement and control technology

H
D

MINI POWER, 1 AC, 5 to 15 V DC
– Easy-to-maintain connection method
thanks to keyed COMBICON connector
– Remote monitoring of output voltage via
switching output

W

MINI POWER, 5 and 10 - 15 V DC
– Adjustable output voltage of 4.5 to
5.5 V DC, or of 10 to 15 V DC
MINI POWER, ±15 V DC
– For supplying operational amplifiers

Power supply,
1 AC, 5 V DC, 3 A


Ex: 

L (+)
NC
NC
N (-)

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage
Output current / POWER BOOST
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Connection data solid / stranded / AWG
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals

Limitation of harmonic line currents

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
0.4 A (120 V AC) / 0.2 A (230 V AC)
< 15 A / 1.5 A2s
> 30 ms (120 V AC) / > 140 ms (230 V AC)
5 V DC ±1%
4.5 V DC ... 5.5 V DC (> 5 V constant capacity)
3A/5A
Yes / Yes
1W/5W
> 73 % (for 230 V AC and nominal values)
< 40 mVPP
LED
0.17 kg / 22.5 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 500000 h
-25 °C ... 70 °C (> 60 °C derating)
3 kV (Routine test) / 4 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Ordering data
Description

Type

Order No.

MINI-PS-100-240AC/ 5DC/3

2938714

Pcs. /
Pkt.

Power supply unit, primary-switched

182

PHOENIX CONTACT

1

Power supply units and UPS
Power supply units
H
D

H
W

H
W

D

Power supply,
1 AC, 10 - 15 V DC, 2 A

D

W

Power supply,
1 AC, 10 - 15 V DC, 8 A


Ex: 

Power supply,
1 AC, ±15 V DC, 1 A


Ex: 


Ex: 

L (+)

L (+)

L (+)
NC
NC
N (-)

NC
NC
N (-)

N (-)

OV
OV

DC OK

Technical data

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
0.4 A (120 V AC) / 0.2 A (230 V AC)
< 15 A / 1.7 A2s
> 20 ms (120 V AC) / > 120 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
1.3 A (120 V AC) / 0.8 A (230 V AC)
< 15 A / 2.1 A2s
> 20 ms (120 V AC) / > 20 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
0.6 A (120 V AC) / 0.4 A (230 V AC)
< 35 A / 4 A2s
> 30 ms (120 V AC) / > 150 ms (230 V AC)

12 V DC ±1%
10 V DC ... 15 V DC (> 12 V constant capacity)

12 V DC ±1%
10 V DC ... 15 V DC (> 12 V constant capacity)

± 15 V DC ±1%
-

2 A / 2.3 A
Yes / Yes
<1W/<7W
> 86 % (for 230 V AC and nominal values)
< 20 mVPP

8 A / 6.6 A
Yes / Yes
< 2.5 W / < 12 W
> 88 % (for 230 V AC and nominal values)
< 40 mVPP

1 A / 1.5 A
Yes / Yes
2W/8W
> 80 % (for 230 V AC and nominal values)
< 30 mVPP

LED

LED, active switching output

LED

0.25 kg / 45 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 507000 h
-25 °C ... 70 °C (> 60 °C derating)

0.4 kg / 67.5 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 984000 h
-25 °C ... 70 °C (> 60 °C derating)

0.25 kg / 45 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 500000 h
-25 °C ... 70 °C (> 60 °C derating)

3 kV (Routine test) / 4 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

3 kV (Routine test) / 3 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

3 kV (Routine test) / 4 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location) , NEC Class 2 as per UL 1310

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

MINI-PS-100-240AC/10-15DC/2

2938756

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

MINI-PS-100-240AC/10-15DC/8

2866297

Pcs. /
Pkt.

1

Type

Order No.

MINI-PS-100-240AC/2X15DC/1

2938743

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

183

Power supply units and UPS
Power supply units
UNO POWER power supply units compact basic functionality
– More space in the control cabinet with up
to 20% higher power density
– Height of housing is just 84 mm, suitable
for all 120 mm control cabinets
– Maximum energy efficiency: energy savings with over 90% efficiency and extremely low idling losses under 0.3 W

H

H
D

W

W

D

Power supply, 1 AC, 24 DC, 30 W

Power supply, 1 AC, 24 DC, 60 W

+
-

L
N

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Output current
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Connection data solid / stranded / AWG
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals
Limitation of harmonic line currents

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
0.5 A (120 V AC) / 0.3 A (230 V AC)
< 20 A / < 0.4 A2s
> 35 ms (120 V AC) / > 140 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
1 A (120 V AC) / 0.6 A (230 V AC)
< 30 A / < 0.5 A2s
> 20 ms (120 V AC) / > 85 ms (230 V AC)

24 V DC ±1%
1.25 A
yes, with redundancy module / Yes
< 0.3 W / < 5 W
> 88 %
< 60 mVPP

24 V DC ±1%
2.5 A
yes, with redundancy module / Yes
< 0.3 W / < 7 W
> 90 %
< 30 mVPP

LED

LED

0.15 kg / 22.5 x 90 x 84 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / II (in an enclosed control cabinet)
> 500000 h
-25 °C ... 70 °C (> 55° C derating)

0.2 kg / 35 x 90 x 84 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 500000 h
-25 °C ... 70 °C (> 55° C derating)

3 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310
EN 61000-3-2

3 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL applied for
EN 61000-3-2

Ordering data
Description

+
+
–
–

L
N

Ordering data

Type

Order No.

UNO-PS/1AC/24DC/30W

2902991

Pcs. /
Pkt.

Type

Order No.

UNO-PS/1AC/24DC/60W

2902992

Pcs. /
Pkt.

Power supply unit, primary-switched, 1-phase

184

PHOENIX CONTACT

1

1

Power supply units and UPS
Power supply units
H

H
W

D

D

Power supply, 1 AC, 24 DC, 100 W

W

D

Power supply, 1 AC, 12 DC, 30 W

+
+
–
–

L
N

H
W

Power supply, 1 AC, 12 DC, 55 W

+
-

L
N

Technical data

+
+
–
–

L
N

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
1.7 A (120 V AC) / 1 A (230 V AC)
< 40 A / < 1.5 A2s
> 20 ms (120 V AC) / > 90 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
0.5 A (120 V AC) / 0.3 A (230 V AC)
< 30 A / < 0.6 A2s
> 20 ms (120 V AC) / > 120 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
1 A (120 V AC) / 0.6 A (230 V AC)
< 30 A / < 0.5 A2s
> 25 ms (120 V AC) / > 125 ms (230 V AC)

24 V DC ±1%
4.2 A
yes, with redundancy module / Yes
< 0.5 W / < 11 W
> 90 %
< 30 mVPP

12 V DC ±1%
2.5 A
yes, with redundancy module / Yes
< 0.3 W / < 5.6 W
> 87 %
< 30 mVPP

12 V DC ±1%
4.6 A
yes, with redundancy module / Yes
< 0.3 W / < 8 W
> 90 %
< 30 mVPP

LED

LED

LED

0.34 kg / 55 x 90 x 84 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 500000 h
-25 °C ... 70 °C (> 55° C derating)

0.15 kg / 22.5 x 90 x 84 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 500000 h
-25 °C ... 70 °C (> 55° C derating)

0.2 kg / 35 x 90 x 84 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / II (in an enclosed control cabinet)
> 500000 h
-25 °C ... 70 °C (> 55° C derating)

3 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL applied for

3 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL applied for

3 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL applied for

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

UNO-PS/1AC/24DC/100W

2902993

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

UNO-PS/1AC/12DC/30W

2902998

Pcs. /
Pkt.

1

Type

Order No.

UNO-PS/1AC/12DC/55W

2902999

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

185

Power supply units and UPS
Power supply units
STEP POWER - power supply units
for distributor boards and flat control
panels
STEP POWER, 1 AC, 24 V DC
– Flexible assembly by simply snapping the
product onto the DIN rail or screwing it
onto an even surface
– Energy savings thanks to maximum energy efficiency and incredibly low no-load
losses
– Wide temperature range from -25°C to
+70°C
– Reliable power supply thanks to the high
MTBF (mean time between failures) of
more than 500,000 hours and the UI characteristic curve

H
D

W

Power supply,
1 AC, 24 V DC, 0.5 A



STEP POWER, 24 V DC, 0.5 A
– Slim design with a design width of just
18 mm (1 pitch)

+
-

L (+)
N (-)

STEP POWER, 24 V DC, 0.75 A
– Flat design with a depth of just 43 mm
STEP POWER, 48 V AC, 0.5 A
– Connection to 48 V AC operating networks
– Slim design with a design width of just
18 mm (1 pitch)

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Output current
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Connection data solid / stranded / AWG
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.28 A (120 V AC) / 0.13 A (230 V AC)
< 15 A / < 0.1 A2s
> 15 ms (120 V AC) / > 90 ms (230 V AC)
24 V DC ±1%
0.5 A
Yes / Yes
< 0.3 W / < 2.2 W
> 84 % (for 230 V AC and nominal values)
< 20 mVPP
LED
0.07 kg / 18 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1567000 h
-25 °C ... 70 °C (> 55° C derating)
3.75 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310

Limitation of harmonic line currents

EN 61000-3-2

Ordering data
Description

Type

Order No.

STEP-PS/ 1AC/24DC/0.5

2868596

Pcs. /
Pkt.

Power supply unit, primary-switched

186

PHOENIX CONTACT

1

Power supply units and UPS
Power supply units
H
D

H
W

H
W

D

Power supply,
1 AC, 24 V DC, 0.75 A,
flat design

D

W

Power supply,
1 AC, 24 V DC, 0.75 A



Power supply,
48 V AC, 24 V DC, 0.5 A

  BSH       
Ex: 

Ex: 

+
+
–
–

L (+)
N (-)



+
+
–
–

L (+)
N (-)

+
-

L (+)
N (-)

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.3 A (120 V AC) / 0.25 A (230 V AC)
< 15 A / < 0.1 A2s
> 15 ms (120 V AC) / > 70 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.3 A (120 V AC) / 0.2 A (230 V AC)
< 15 A / < 0.1 A2s
> 15 ms (120 V AC) / > 70 ms (230 V AC)

48 V AC
43 V AC ... 52 V AC / 60 V DC ... 80 V DC
45 Hz ... 65 Hz / 0 Hz
0.5 A (43 V AC) / 0.45 A (48 V AC)
< 10 A / < 0.1 A2s
> 15 ms (48 V AC) / > 20 ms (52 V AC)

24 V DC ±1%
0.75 A
Yes / Yes
< 0.5 W / < 3.6 W
> 84 % (for 230 V AC and nominal values)
< 75 mVPP

24 V DC ±1%
0.75 A
Yes / Yes
< 0.5 W / 3.6 W
> 84 % (for 230 V AC and nominal values)
< 75 mVPP

24 V DC ±1%
0.5 A
Yes / Yes
< 0.3 W / < 3.4 W
> 81 % (for 48 V AC and nominal values)
< 30 mVPP

LED

LED

LED

0.11 kg / 36 x 90 x 43 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 926000 h
-25 °C ... 70 °C (> 55° C derating)

0.11 kg / 36 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 926000 h
-25 °C ... 70 °C (> 55° C derating)

0.07 kg / 18 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1860000 h
-25 °C ... 70 °C (> 55° C derating)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I,
Division 2, Groups A, B, C, D (Hazardous Location)

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I,
Division 2, Groups A, B, C, D (Hazardous Location)

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Technical data

Ordering data

Type

Order No.

STEP-PS/ 1AC/24DC/0.75/FL

2868622

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

STEP-PS/ 1AC/24DC/0.75

2868635

Pcs. /
Pkt.

1

Type

Order No.

STEP-PS/48AC/24DC/0.5

2868716

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

187

Power supply units and UPS
Power supply units
STEP POWER - power supply units
for distributor boards and flat control
panels
STEP POWER, 1 AC, 24 V DC
– Flexible assembly by simply snapping the
product onto the DIN rail or screwing it
onto an even surface
– Energy savings thanks to maximum energy efficiency and incredibly low no-load
losses
– Wide temperature range from -25°C to
+70°C
– Reliable power supply thanks to the high
MTBF (mean time between failures) of
more than 500,000 hours and the UI characteristic curve
– Adjustable output voltage of 22.5 to
29.5 V DC

H
D

W

Power supply,
1 AC, 24 V DC, 1.75 A

  BSH   
Ex: 

STEP POWER, 100 W
– Output power limited to 100 W: specifically for applications that require certification according to UL 1310/508 Listed
Class 2
– Approved for DeviceNet™

+
+
–
–

L (+)
N (-)

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage
Output current
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Connection data solid / stranded / AWG
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.6 A (120 V AC) / 0.3 A (230 V AC)
< 15 A / < 0.6 A2s
> 25 ms (120 V AC) / > 150 ms (230 V AC)
24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)
1.75 A
Yes / Yes
< 0.7 W / 5 W
> 89 % (for 230 V AC and nominal values)
< 60 mVPP
LED
0.19 kg / 54 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1569000 h
-25 °C ... 70 °C (> 55° C derating)
3.75 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I,
Division 2, Groups A, B, C, D (Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

Ordering data
Description

Type

Order No.

STEP-PS/ 1AC/24DC/1.75

2868648

Pcs. /
Pkt.

Power supply unit, primary-switched

188

PHOENIX CONTACT

1

Power supply units and UPS
Power supply units
H
D

H
W

D

H
W

Power supply,
1 AC, 24 V DC, 2.5 A

D

W

Power supply,
1 AC, 24 V DC, 100 W
NEC Class 2

  BSH       
Ex: 

Power supply,
1 AC, 24 V DC, 4.2 A


Ex: 

+
+
–
–

L (+)
N (-)

  BSH   
Ex: 

+
+
–
–

L (+)
N (-)

+
+
–
–

L (+)
N (-)

Technical data

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.8 A (120 V AC) / 0.4 A (230 V AC)
< 15 A / < 0.6 A2s
> 20 ms (120 V AC) / > 100 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
1.3 A (120 V AC) / 0.8 A (230 V AC)
< 15 A / < 1 A2s
> 25 ms (120 V AC) / > 120 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
1.3 A (120 V AC) / 0.8 A (230 V AC)
< 15 A / < 1 A2s
> 20 ms (120 V AC) / > 100 ms (230 V AC)

24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
22.5 V DC ... 25 V DC (> 24 V constant capacity)

24 V DC ±1%
22.5 V DC ... 29.5 V DC (> 24 V constant capacity)

2.5 A
Yes / Yes
< 0.7 W / 9.9 W
> 86 % (for 230 V AC and nominal values)
< 80 mVPP

3.8 A
No / No
< 0.7 W / 11.8 W
> 88 % (for 230 V AC and nominal values)
< 80 mVPP

4.2 A
Yes / Yes
< 0.7 W / 13.2 W
> 88 % (for 230 V AC and nominal values)
< 40 mVPP

LED

LED

LED

0.27 kg / 72 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1061000 h
-25 °C ... 70 °C (> 55° C derating)

0.33 kg / 90 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 897000 h
-25 °C ... 70 °C (> 55° C derating)

0.33 kg / 90 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 897498 h
-25 °C ... 70 °C (> 55° C derating)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I,
Division 2, Groups A, B, C, D (Hazardous Location)

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I,
Division 2, Groups A, B, C, D (Hazardous Location)

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

STEP-PS/ 1AC/24DC/2.5

2868651

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

STEP-PS/ 1AC/24DC/3.8/C2LPS

2868677

Pcs. /
Pkt.

1

Type

Order No.

STEP-PS/ 1AC/24DC/4.2

2868664

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

189

Power supply units and UPS
Power supply units
STEP POWER - power supply units
for distributor boards and flat control
panels
STEP POWER, 1 AC, 5 to 48 V DC
– Flexible assembly by simply snapping the
product onto the DIN rail or screwing it
onto an even surface
– Energy savings thanks to maximum energy efficiency and incredibly low no-load
losses
– Wide temperature range from -25°C to
+70°C
– Reliable power supply thanks to the high
MTBF (mean time between failures) of
more than 500,000 hours and the UI characteristic curve

H
D

W

Power supply,
1 AC, 5 V DC, 2 A

STEP POWER, 5 V DC, 2 A
– Slim design with a design width of just
18 mm (1 pitch)

+
-

L (+)
N (-)

STEP POWER, 5 V DC, 6.5 A
– Adjustable output voltage of 4 to
6.5 V DC
STEP POWER, 15 V DC, 4 A
– Adjustable output voltage of 10 to
16.5 V DC
STEP POWER, 48 V DC, 2 A
– Adjustable output voltage of 30 to
56 V DC

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage
Output current
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Connection data solid / stranded / AWG
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.2 A (120 V AC) / 0.13 A (230 V AC)
< 15 A / < 0.1 A2s
> 20 ms (120 V AC) / > 100 ms (230 V AC)
5 V DC ±1%
2A
Yes / Yes
< 0.4 W / < 2.7 W
> 80 % (for 230 V AC and nominal values)
< 20 mVPP
LED
0.07 kg / 18 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 500000 h
-25 °C ... 70 °C (> 55° C derating)
3.75 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310

Limitation of harmonic line currents

EN 61000-3-2

Ordering data
Description

Type

Order No.

STEP-PS/ 1AC/5DC/2

2320513

Pcs. /
Pkt.

Power supply unit, primary-switched, 1-phase

190

PHOENIX CONTACT

1

Power supply units and UPS
Power supply units
H
D

H
W

H
W

D

Power supply,
1 AC, 5 V DC, 6.5 A

D

Power supply,
1 AC, 15 V DC, 4 A


Ex: 

Power supply,
1 AC, 48 V DC, 2 A


Ex: 

+
+
–
–

L (+)
N (-)

W


Ex: 

+
+
–
–

L (+)
N (-)

+
+
–
–

L (+)
N (-)

Technical data

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.5 A (120 V AC) / 0.3 A (230 V AC)
< 15 A / < 0.6 A2s
> 25 ms (120 V AC) / > 140 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.8 A (120 V AC) / 0.5 A (230 V AC)
< 15 A / < 0.6 A2s
> 27 ms (120 V AC) / > 120 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
1.3 A (120 V AC) / 0.8 A (230 V AC)
< 15 A / < 1.4 A2s
> 20 ms (120 V AC) / > 120 ms (230 V AC)

5 V DC ±1%
4 V DC ... 6.5 V DC (> 5 V constant capacity)

15 V DC ±1%
10 V DC ... 16.5 V DC (> 15 V constant capacity)

48 V DC ±1%
30 V DC ... 56 V DC (> 48 V constant capacity)

6.5 A
Yes / Yes
< 0.4 W / 8.1 W
> 80 % (for 230 V AC and nominal values)
< 50 mVPP

4A
Yes / Yes
< 0.5 W / 8.6 W
> 87 % (for 230 V AC and nominal values)
< 55 mVPP

2A
Yes / Yes
< 0.9 W / 9.6 W
> 90 % (for 230 V AC and nominal values)
< 30 mVPP

LED

LED

LED

0.27 kg / 72 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1111000 h
-25 °C ... 70 °C (> 55° C derating)

0.27 kg / 72 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1134000 h
-25 °C ... 70 °C (> 55° C derating)

0.33 kg / 90 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1048000 h
-25 °C ... 70 °C (> 55° C derating)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

STEP-PS/ 1AC/ 5DC/6.5

2868541

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

STEP-PS/ 1AC/15DC/4

2868619

Pcs. /
Pkt.

1

Type

Order No.

STEP-PS/ 1AC/48DC/2

2868680

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

191

Power supply units and UPS
Power supply units
STEP POWER - power supply units
for distributor boards and flat control
panels
STEP POWER, 1 AC, 12 V DC
– Flexible assembly by simply snapping the
product onto the DIN rail or screwing it
onto an even surface
– Energy savings thanks to maximum energy efficiency and incredibly low no-load
losses
– Wide temperature range from -25°C to
+70°C
– Reliable power supply thanks to the high
MTBF (mean time between failures) of
more than 500,000 hours and the UI characteristic curve

H

H
D

W

D

W

Power supply,
1 AC, 12 V DC, 1 A

Power supply,
1 AC, 12 V DC, 1.5 A,
flat design


Ex: 



+
-

L (+)
N (-)

+
+
–
–

L (+)
N (-)

Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage
Output current
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Connection data solid / stranded / AWG
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.26 A (120 V AC) / 0.13 A (230 V AC)
< 15 A / < 0.1 A2s
> 15 ms (120 V AC) / > 90 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.33 A (120 V AC) / 0.18 A (230 V AC)
< 15 A / < 0.1 A2s
> 15 ms (120 V AC) / > 70 ms (230 V AC)

12 V DC ±1%
-

12 V DC ±1%
-

1A
Yes / Yes
< 0.4 W / < 2.8 W
> 83 % (for 230 V AC and nominal values)
< 20 mVPP

1.5 A
Yes / Yes
< 0.4 W / < 3.2 W
> 84 % (for 230 V AC and nominal values)
< 75 mVPP

LED

LED

0.07 kg / 18 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1478000 h
-25 °C ... 70 °C (> 55° C derating)

0.07 kg / 36 x 90 x 43 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1800000 h
-25 °C ... 70 °C (> 55° C derating)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I,
Division 2, Groups A, B, C, D (Hazardous Location)

Limitation of harmonic line currents

EN 61000-3-2

EN 61000-3-2

Ordering data
Description

Ordering data

Type

Order No.

STEP-PS/ 1AC/12DC/1

2868538

Pcs. /
Pkt.

Type

Order No.

STEP-PS/ 1AC/12DC/1.5/FL

2868554

Pcs. /
Pkt.

Power supply unit, primary-switched

192

PHOENIX CONTACT

1

1

Power supply units and UPS
Power supply units
H
D

H
W

H
W

D

Power supply,
1 AC, 12 V DC, 1.5 A

D

W

Power supply,
1 AC, 12 V DC, 3 A


Ex: 

Power supply,
1 AC, 12 V DC, 5 A


Ex: 

+
+
–
–

L (+)
N (-)


Ex: 

+
+
–
–

L (+)
N (-)

+
+
–
–

L (+)
N (-)

Technical data

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.3 A (120 V AC) / 0.2 A (230 V AC)
< 15 A / < 0.1 A2s
> 15 ms (120 V AC) / > 70 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.6 A (120 V AC) / 0.3 A (230 V AC)
< 15 A / < 0.6 A2s
> 26 ms (120 V AC) / > 160 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 95 V DC ... 250 V DC
45 Hz ... 65 Hz / 0 Hz
0.8 A (120 V AC) / 0.5 A (230 V AC)
< 15 A / < 0.6 A2s
> 27 ms (120 V AC) / > 120 ms (230 V AC)

12 V DC ±1%
-

12 V DC ±1%
10 V DC ... 16.5 V DC (> 12 V constant capacity)

12 V DC ±1%
10 V DC ... 16.5 V DC (> 12 V constant capacity)

1.5 A
Yes / Yes
< 0.4 W / < 3.2 W
> 84 % (for 230 V AC and nominal values)
< 75 mVPP

3A
Yes / Yes
< 0.5 W / 6.4 W
> 85 % (for 230 V AC and nominal values)
< 40 mVPP

5A
Yes / Yes
< 0.5 W / 8.6 W
> 87 % (for 230 V AC and nominal values)
< 55 mVPP

LED

LED

LED

0.11 kg / 36 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1800000 h
-25 °C ... 70 °C (> 55° C derating)

0.19 kg / 54 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1689000 h
-25 °C ... 70 °C (> 55° C derating)

0.27 kg / 72 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 1134000 h
-25 °C ... 70 °C (> 55° C derating)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

3.75 kV AC (routine test) / 4 kV AC (type test)

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I,
Division 2, Groups A, B, C, D (Hazardous Location)

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
NEC Class 2 as per UL 1310 , UL ANSI/ISA-12.12.01 Class I,
Division 2, Groups A, B, C, D (Hazardous Location)

Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

EN 61000-3-2

EN 61000-3-2

EN 61000-3-2

Ordering data

Ordering data

Type

Order No.

STEP-PS/ 1AC/12DC/1.5

2868567

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

STEP-PS/ 1AC/12DC/3

2868570

Pcs. /
Pkt.

1

Type

Order No.

STEP-PS/ 1AC/12DC/5

2868583

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

193

Power supply units and UPS
Power supply units
Power supply units for extreme ambient conditions
QUINT POWER, dip-coated
With ATEX approval for maximum system availability under extreme ambient conditions, such as dust, dirt, corrosive gases,
and 100% humidity
– Complies with standard EN 60079-15 and
may be installed in a potentially explosive
area.
– They are suitable for use in Class I, Division 2, Groups A, B, C, D
MINI POWER EX
Corresponds to standard EN 60079-15
– Installation within potentially explosive
area in which category 3G items are necessary

Power supply,
dip-coated,
1 AC, 24 V DC, 5 A

Power supply,
dip-coated,
1 AC, 24 V DC, 10 A


Ex:  


Ex:   

L (+)

L (+)

Notes:

active

MINI-PS...: DIN rail connector (optional), for routing through the
supply voltage and data signal, two required per device (ME 17,5
TBUS 1,5/5-ST-3,81 GN, 2709561).

Input data
Nominal input voltage range
Input voltage range AC/DC
Frequency range
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Mains buffering (IN, typ.)
Output data
Nominal output voltage
Setting range of the output voltage
Output current / POWER BOOST / SFB (12 ms)
Magnetic fuse tripping
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
Boost signaling
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
Rail applications
UL approvals

Limitation of harmonic line currents

N (-)

active

PFC

N (-)

DC OK
I < IN

DC OK
I < IN

13

13

14

14

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 430 V DC
45 Hz ... 65 Hz / 0 Hz
1.2 A (120 V AC) / 0.6 A (230 V AC)
< 15 A / < 1 A2s
> 25 ms (120 V AC) / > 25 ms (230 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 430 V DC
45 Hz ... 65 Hz / 0 Hz
2.24 A (120 V AC) / 1.33 A (230 V AC)
< 15 A / < 1.5 A2s
> 27 ms (120 V AC) / > 31 ms (230 V AC)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

5 A / 7.5 A / 30 A
B2 , B4 , C2
Yes / Yes
3 W / 15 W
> 90 % (for 230 V AC and nominal values)
< 40 mVPP

10 A / 15 A / 60 A
B2 , B4 , B6 , C2 , C4
Yes / Yes
9.1 W / 22 W
> 92.5 % (for 230 V AC and nominal values)
< 50 mVPP

LED, active switching output, relay contact
LED, active switching output

LED, active switching output, relay contact
LED, active switching output

0.7 kg / 40 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
IP20 / I
> 635000 h
-40 °C ... 70 °C (ATEX/IECEx: -25°C ... +60°C)

1.1 kg / 60 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
IP20 / I
> 535000 h
-40 °C ... 70 °C (ATEX/IECEx: -25°C ... +60°C)

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
EN 50121-4 / EN 50155
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
EN 50121-4 / EN 50155
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Ordering data
Description

PFC

Ordering data

Type

Order No.

QUINT-PS/ 1AC/24DC/ 5/CO

2320908

Pcs. /
Pkt.

Type

Order No.

QUINT-PS/ 1AC/24DC/10/CO

2320911

Pcs. /
Pkt.

Power supply unit, primary-switched

194

PHOENIX CONTACT

1

1

Power supply units and UPS
Power supply units
H
D

H
W

D

Power supply,
dip-coated,
1 AC, 24 V DC, 20 A

H
W

Power supply,
dip-coated,
3 AC, 24 V DC, 20 A





L (+)

L1 (+)

Power supply
1 AC, 24 DC, 1.5 A
DIN rail connector optional



Ex: 

24V

L2

active

N (-)

W

D

PFC

L

0V

L3 (-)

0V

NC
DC OK
I < IN

DC OK
I < IN

13

13

14

14

Technical data

24V
13

N

14

Technical data

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 90 V DC ... 350 V DC
45 Hz ... 65 Hz / 0 Hz
5.1 A (120 V AC) / 2.3 A (230 V AC)
< 20 A / < 3.2 A2s
> 20 ms (120 V AC) / > 20 ms (230 V AC)

3x 400 V AC ... 500 V AC
320 V AC ... 575 V AC / 450 V DC ... 800 V DC
45 Hz ... 65 Hz / 0 Hz
3x 1.6 A (400 V AC) / 3x 1.3 A (500 V AC)
< 20 A / < 3.2 A2s
> 15 ms (400 V AC) / > 25 ms (500 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC
45 Hz ... 65 Hz
0.75 A (120 V AC) / 0.45 A (230 V AC)
< 15 A / 0.6 A2s
> 20 ms (120 V AC) / > 100 ms (230 V AC)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
-

20 A / 26 A / 120 A
B2 , B4 , B6 , B10 , B16 , C2 , C4 , C6
Yes / Yes
8 W / 40 W
> 93 % (for 230 V AC and nominal values)
< 30 mVPP

20 A / 26 A / 120 A
B2 , B4 , B6 , B10 , B16 , C2 , C4 , C6
Yes / Yes
11 W / 40 W
> 93 % (at 400 V AC and nominal values)
< 40 mVPP

1.5 A / 2 A
Yes / Yes
2.5 W / 12 W
> 84 % (for 230 V AC and nominal values)
< 40 mVPP

LED, active switching output, relay contact
LED, active switching output

LED, active switching output, relay contact
LED, active switching output

LED, relay contact
-

1.7 kg / 90 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
IP20 / I
> 520000 h
-25 °C ... 70 °C (> 60 °C derating)

1.5 kg / 69 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 18 - 10
IP20 / I
> 534000 h
-40 °C ... 70 °C (> 60 °C derating)

0.25 kg / 35 x 99 x 95 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
EN 50121-4 / EN 50155
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

2 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
EN 50121-4 / EN 50155
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)
EN 61000-3-2

Ordering data

Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.5 - 16 mm² / 0.5 - 10 mm² / 20 - 6
IP20 / II (in an enclosed control cabinet)
> 2789000 h
-25 °C ... 70 °C (> 60 °C derating)

3 kV AC (routine test) / 4 kV AC (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-1010
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

EN 61000-3-2

Ordering data

Type

Order No.

QUINT-PS/ 1AC/24DC/20/CO

2320898

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

QUINT-PS/ 3AC/24DC/20/CO

2320924

Pcs. /
Pkt.

1

Type

Order No.

MINI-PS-100-240AC/24DC/1.5/EX

2866653

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

195

Power supply units and UPS
DC/DC converters

QUINT and MINI DC/DC converters
alter the voltage level, regenerate the
voltage at the end of long cables, or
enable the creation of independent
supply systems by means of electrical
isolation.
There are numerous fields of application
for DC/DC converters. As the name suggests, they convert voltages in order to
match different voltage levels to one another. On long supply lines, they raise the voltage to compensate for voltage drops.
DC/DC converters separate circuits from
each other using electrical isolation and protect the sensitive loads by decoupling them.
The primary-switched switching devices
have an internal intermediate circuit. This
acts as a filter. This means, for example, that
grounded and ungrounded circuits can be
kept separate. A further advantage is the
protection of critical loads from damaging
voltage fluctuations: if, for example, a motor
is switched on that requires a higher current
for the starting torque, there is a short voltage dip. The same occurs when loads with
high input capacities are switched on. Troubleshooting these temporary faults is often
difficult and time-consuming.
DC/DC converters are also ideal in battery-supported power supply networks or
196

PHOENIX CONTACT

solutions with unregulated transformers,
when sensitive loads require a stable DC.
QUINT POWER for maximum system availability
Cost-effective selective fuse protection
with SFB technology:
In order to trip standard circuit breakers
magnetically and quickly, power supply units
must be able to supply several times the
nominal current for a short period. With
SFB (Selective Fuse Breaking) technology,
which supplies up to 6 times the nominal
current for 12 ms, a dynamic power reserve
is available. Faulty current paths are selectively switched off, the fault is isolated, and
important system components remain operational.
Preventive function monitoring:
Comprehensive diagnostics are provided
through constant monitoring of the output
voltage and current. This constant, preventive monitoring of input voltage, output
voltage, and output current visualizes critical operating states before errors can occur.
Remote monitoring is provided by means of
active switching outputs and floating relay
contacts.

POWER BOOST power reserve:
The static power reserve offers up to 1.25
times the nominal current permanently. At
ambient temperatures of up to +40°C the
POWER BOOST is continuously available
and at higher temperatures, it is available for
a few minutes. This ensures that both high
inrush currents of capacitive loads, as well as
loads with DC/DC converters in the primary circuit, can be reliably supplied.

Power supply units and UPS
DC/DC converters

For maximum system availability
The unique SFB technology and preventive function monitoring maximize the availability of your application.
– Quick tripping of the standard power circuit breakers
– Preventive function monitoring
– Reliable starting of heavy loads

Maximum system availability with
SFB technology
SFB technology using a frayed display cable as an example:
– The fuse triggers immediately, the lower
lever display is dark.
– The controller, sensors, and actuators
continue to operate without interruption.
– Production continues.

MINI DC/DC converter - for control
technology
MINI DC/DC converters come into their
own in fields where modular electronics
housing has become the standard.
– Service-friendly connection technology
with COMBICON encoded plug-in connectors
– Active function monitoring with switching
output for remote monitoring of the output voltage

Voltage levels of QUINT DC/DC converters
The QUINT DC/DC converters alter the
voltage level:
– Input voltages: 12 V DC, 24 V DC,
48 V DC
– Output voltages: 12 V DC, 24 V DC,
48 V DC

Voltage levels of MINI DC/DC converters
The MINI DC/DC converters alter the
voltage level:
– Input voltages: 12 V DC, 24 V DC,
48 V DC
– Output voltages: 5...15 V DC, 24 V DC,
48 V DC

TRIO for frequency inverters
– Direct connection to the 600 V DC intermediate circuit of a frequency inverter
– Mains failure: 24 V loads continue to be
supplied using the kinetic energy of the
motor. In this case, the motors act as generators and supply energy to the intermediate circuit.
Details about this product can be found
on page 178

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

197

Power supply units and UPS
DC/DC converters
QUINT DC/DC converters, 24 V DC
H

H

– Support conversion to various voltage
levels
– Constant voltage: output voltage regenerated even at the end of long cables
– Electrical isolation: for setting up independent supply systems
– SFB technology: fast tripping of standard
circuit breakers, thanks to the dynamic
power reserve with up to 6 times the
nominal current for 12 ms
– Reliable starting of heavy loads thanks to
the static POWER BOOST power reserve with permanently up to 125% of the
nominal current
– Preventive function monitoring warns
against critical operating states before errors occur

W

D

W

D

DC/DC converter,
24 V DC / 24 V DC, 5 A

DC/DC converter,
24 V DC / 24 V DC, 10 A


Ex: 



Ex: 

+
+
-

+
-

+
+
-

+
-

UIN>19,2 V

UIN>19,2 V

DC OK

DC OK

I 10 ms (24 V DC)

24 V DC
18 V DC ... 32 V DC
14 A (24 V DC)
< 15 A / < 2.7 A2s
> 12 ms (24 V DC)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

5 A / 6.25 A / 30 A
B2 , B4 , C2
Yes / Yes
2.4 W / 11.4 W
> 92 %
< 20 mVPP

10 A / 12.5 A / 60 A
B2 , B4 , B6 , C2 , C4
Yes / Yes
1.6 W / 24 W
> 92 %
< 20 mVPP

LED, active switching output
LED, active switching output
LED, active switching output

LED, active switching output, relay contact
LED, active switching output
LED, active switching output

0.7 kg / 32 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 890000 h
-25 °C ... 70 °C (> 60 °C derating)
≤ 95 % (at 25 °C, no condensation)

0.9 kg / 48 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 763000 h
-25 °C ... 70 °C (> 60 °C derating)
≤ 95 % (at 25 °C, no condensation)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

Ordering data
Description

Ordering data

Type

Order No.

QUINT-PS/24DC/24DC/ 5

2320034

Pcs. /
Pkt.

Type

Order No.

QUINT-PS/24DC/24DC/10

2320092

Pcs. /
Pkt.

DC/DC converter, primary switched mode

198

PHOENIX CONTACT

1

1

Power supply units and UPS
DC/DC converters
H

H
W

D

H
W

D

DC/DC converter,
24 V DC / 24 V DC, 20 A


Ex: 

+
+
-

+
-

W

D

DC/DC converter,
24 V DC / 12 V DC, 8 A

DC/DC converter,
24 V DC / 48 V DC, 5 A


Ex: 


Ex: 

+
+
-

UIN>19,2 V

+
+
-

DC OK

UIN>19,2 V

DC OK

I19,2 V

I 10 ms (24 V DC)

24 V DC
18 V DC ... 32 V DC
6 A (24 V DC)
< 15 A / < 0.5 A2s
> 10 ms (24 V DC)

24 V DC
18 V DC ... 32 V DC
14 A (24 V DC)
< 15 A / 3 A2s
> 12 ms (24 V DC)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

12 V DC ±1%
5 V DC ... 18 V DC (> 12 V constant capacity)

48 V DC ±1%
30 V DC ... 56 V DC (> 48 V constant capacity)

20 A / 25 A / 120 A
B2 , B4 , B6 , B10 , B16 , C2 , C4 , C6
Yes / Yes
2.2 W / 39 W
> 93 %
< 20 mVPP

8 A / 10 A / 48 A
B2 , B4 , C2
Yes / Yes
2 W / 10.5 W
> 90 %
< 20 mVPP

5 A / 6.25 A / 30 A
B2 , B4 , C2
Yes / Yes
5.2 W / 21 W
> 92.5 %
< 20 mVPP

LED, active switching output, relay contact
LED, active switching output
LED, active switching output

LED, active switching output
LED, active switching output
LED, active switching output

LED, active switching output, relay contact
LED, active switching output
LED, active switching output

1.7 kg / 82 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.5 - 16 mm² / 0.5 - 16 mm² / 8 - 6
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 554000 h
-25 °C ... 70 °C (> 60 °C derating)
≤ 95 % (at 25 °C, no condensation)

0.7 kg / 32 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 843000 h
-25 °C ... 70 °C (> 60 °C derating)
≤ 95 % (at 25 °C, no condensation)

0.9 kg / 48 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 461000 h
-25 °C ... 70 °C (> 60 °C derating)
≤ 95 % (at 25 °C, no condensation)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

Ordering data

Ordering data

Type

Order No.

QUINT-PS/24DC/24DC/20

2320102

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

QUINT-PS/24DC/12DC/ 8

2320115

Pcs. /
Pkt.

1

Type

Order No.

QUINT-PS/24DC/48DC/ 5

2320128

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

199

Power supply units and UPS
DC/DC converters
QUINT DC/DC converters
H

H

QUINT DC/DC converter, 12 and
48 V DC
– SFB technology: quick tripping of standard circuit breakers
– Reliably start difficult loads, thanks to the
static POWER BOOST power reserve
– Preventive function monitoring
QUINT DC/DC converter, 24 V DC,
dip-coated
– For maximum system availability under
extreme ambient conditions, such as
dust, dirt, corrosive gases, and 100% humidity
– They are suitable for use in Class I, Division 2, Groups A, B, C, D

D

W

W

D

DC/DC converter,
12 V DC / 24 V DC, 5 A

DC/DC converter,
48 V DC / 24 V DC, 5 A


Ex: 



Ex: 

+
+

+
-

UIN>9,6V

UIN<38,4V

DC OK

DC OK

I 3 ms (12 V DC)

48 V DC
30 V DC ... 60 V DC
3.5 A (48 V DC)
< 5 A / < 0.2 A2s
> 14 ms (48 V DC)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

5 A / 6.25 A / 30 A
B2 , B4 , C2
Yes / Yes
2 W / 13.5 W
> 90 %
< 75 mVPP

5 A / 6.25 A / 30 A
B2 , B4 , C2
Yes / Yes
2.7 W / 11 W
> 91.5 %
< 25 mVPP

LED, active switching output
LED, active switching output
LED, active switching output

LED, active switching output
LED, active switching output
LED, active switching output

0.7 kg / 32 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 18 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 18 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 18 - 12
IP20 / III
> 1005000 h
-25 °C ... 70 °C (> 60 °C derating)
≤ 95 % (at 25 °C, no condensation)

0.7 kg / 32 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 18 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 18 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 18 - 12
IP20 / III
> 995000 h
-25 °C ... 70 °C (> 60 °C derating)
≤ 95 % (at 25 °C, no condensation)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

Ordering data
Description

-

Ordering data

Type

Order No.

QUINT-PS/12DC/24DC/5

2320131

Pcs. /
Pkt.

Type

Order No.

QUINT-PS/48DC/24DC/5

2320144

Pcs. /
Pkt.

DC/DC converter, primary switched mode

200

PHOENIX CONTACT

1

1

Power supply units and UPS
DC/DC converters
H

H
W

D

DC/DC converter,
dip-coated,
24 V DC/24 V DC, 5 A

W

D

DC/DC converter,
dip-coated,
24 V DC/24 V DC, 10 A

+
+
-

+
-

H
W

D

DC/DC converter,
dip-coated,
24 V DC/24 V DC, 20 A

+
+
-

+
-

+
+
-

+
-

UIN>19,2 V

UIN>19,2 V

UIN>19,2 V

DC OK

DC OK

DC OK

I 10 ms (24 V DC)

24 V DC
18 V DC ... 32 V DC
14 A (24 V DC)
< 15 A / < 2.7 A2s
> 12 ms (24 V DC)

24 V DC
18 V DC ... 32 V DC
28 A (24 V DC)
< 26 A / < 11 A2s
> 10 ms (24 V DC)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

24 V DC ±1%
18 V DC ... 29.5 V DC (> 24 V constant capacity)

5 A / 6.25 A / 30 A
B2 , B4 , C2
Yes / Yes
2.4 W / 11.4 W
> 92 %
< 20 mVPP

10 A / 12.5 A / 60 A
B2 , B4 , B6 , C2 , C4
Yes / Yes
1.6 W / 24 W
> 92 %
< 20 mVPP

20 A / 25 A / 120 A
B2 , B4 , B6 , B10 , B16 , C2 , C4 , C6
Yes / Yes
2.2 W / 39 W
> 93 %
< 20 mVPP

LED, active switching output
LED, active switching output
LED, active switching output

LED, active switching output, relay contact
LED, active switching output
LED, active switching output

LED, active switching output, relay contact
LED, active switching output
LED, active switching output

0.7 kg / 32 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 890000 h
-25 °C ... 70 °C (> 60 °C derating)
100 % (at 25 °C, no condensation)

0.9 kg / 60 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 763000 h
-25 °C ... 70 °C (> 60 °C derating)
100 % (at 25 °C, no condensation)

1.7 kg / 82 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.5 - 16 mm² / 0.5 - 16 mm² / 8 - 6
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 554000 h
-25 °C ... 70 °C (> 60 °C derating)
100 % (at 25 °C, no condensation)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
EN 50121-4 / EN 50155
UL applied for

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
EN 50121-4 / EN 50155
UL applied for

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
EN 50121-4 / EN 50155
UL applied for

Ordering data

Ordering data

Type

Order No.

QUINT-PS/24DC/24DC/5/CO

2320542

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

QUINT-PS/24DC/24DC/10/CO

2320555

Pcs. /
Pkt.

1

Type

Order No.

QUINT-PS/24DC/24DC/20/CO

2320568

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

201

Power supply units and UPS
DC/DC converters
MINI DC/DC converters
H

H

– Support conversion to various voltage
levels
– Constant voltage: output voltage regenerated even at the end of long cables
– Electrical isolation: for setting up independent supply systems
MINI AC power terminal block
– For supplying MINI DC/DC converters
from unregulated AC networks
– A transformer's AC voltage is rectified
and filtered

D

W

D

DC/DC converter,
12 - 24 V DC / 24 V DC, 1 A

W

DC/DC converter,
12 - 24 V DC / 5 - 15 V DC, 2 A


Ex: 



NC
NC

NC
NC
DC OK

DC OK

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Current consumption (nominal load)
Inrush current limitation at 25°C (typ.) / I2t
Output data
Nominal output voltage
Setting range of the output voltage
Output current
Can be connected in parallel / series
Max. power dissipation (no load / nominal load)
Efficiency (typ.)
Residual ripple
Signaling
Signaling DC OK
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Max. permissible relative humidity (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
Safe isolation
UL approvals

Technical data

12 V DC ... 24 V DC
- / 10 V DC ... 32 V DC
2.6 A (12 V DC) / 1.3 A (24 V DC)
< 15 A / 1.8 A2s

12 V DC ... 24 V DC
- / 10 V DC ... 32 V DC
2.3 A (12 V DC) / 1.1 A (24 V DC)
< 10 A / 0.2 A2s

24 V DC ±1%
22.5 V DC ... 28.5 V DC (> 24 V constant capacity)

12 V DC ±1%
5 V DC ... 15 V DC

1A
Yes / Yes
< 1.2 W / < 5 W
> 83 % (at 24 V DC and nominal values)
< 30 mVPP

2A
Yes / Yes
< 1 W / < 4.2 W
> 88 % (at 24 V DC and nominal values)
< 20 mVPP

LED, active switching output

LED, active switching output

0.2 kg / 22.5 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / III
> 2569000 h
-25 °C ... 70 °C (> 60 °C derating)
≤ 95 % (at 25 °C, no condensation)

0.2 kg / 22.5 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / III
> 2072000 h
-25 °C ... 70 °C (> +60°C derating)
≤ 95 % (At +25°C, no condensation)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-101
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-101
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data
Description

Ordering data

Type

Order No.

MINI-PS- 12- 24DC/24DC/1

2866284

Pcs. /
Pkt.

Type

Order No.

MINI-PS- 12- 24DC/ 5-15DC/2

2320018

Pcs. /
Pkt.

DC/DC converter, primary switched mode

202

PHOENIX CONTACT

1

1

Power supply units and UPS
DC/DC converters
H
D

H
W

H
W

D

DC/DC converter,
12 - 24 V DC / 48 V DC, 0.7 A

D

W

DC/DC converter,
48 - 60 V DC / 24 V DC, 1 A

AC power terminal for
MINI DC/DC converter





Ex: 

NC
NC



NC
NC
DC OK

NC

(+)

~
~

NC
NC
(-)

DC OK

NC

Technical data

Technical data

Technical data

12 V DC ... 24 V DC
- / 10 V DC ... 32 V DC
3.2 A (12 V DC) / 1.6 A (24 V DC)
< 10 A / 0.3 A2s

48 V DC ... 60 V DC
- / 36 V DC ... 75 V DC
0.6 A (48 V DC) / 0.5 A (60 V DC)
< 15 A / 1.8 A2s

10 V AC ... 42 V AC
0 V AC ... 42 V AC
6.5 A
< 45 A / 8 A2s

48 V DC ±1%
30 V DC ... 56 V DC (> 48 V constant capacity)

24 V DC ±1%
22.5 V DC ... 28.5 V DC (> 24 V constant capacity)

24 V DC ±1%
-

0.7 A
Yes / Yes
< 1.5 W / < 4.5 W
> 87 % (at 24 V DC and nominal values)
< 20 mVPP

1A
Yes / Yes
< 1.2 W / < 5 W
> 85 % (at 60 V DC and nominal values)
< 40 mVPP

3A
Yes / No
< 0.04 W / < 6.9 W
> 95.7 % (For 42 V AC and nominal values)
< 3.6 VPP

LED, active switching output

LED, active switching output

-

0.2 kg / 22.5 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / III
> 1993000 h
-25 °C ... 70 °C (> +60°C derating)
≤ 95 % (At +25°C, no condensation)

0.2 kg / 22.5 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
IP20 / II
> 1147000 h
-25 °C ... 70 °C (> 60 °C derating)
≤ 95 % (at 25 °C, no condensation)

0.16 kg / 22.5 x 99 x 107 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
-/-/IP20 / III
> 18175000 h
-25 °C ... 70 °C (> 60 °C derating)
≤ 95 % (at 25 °C, no condensation)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-101
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410 , DIN VDE 0106-101
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

1 kV (routine test) / 1.5 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data

Ordering data

Type

Order No.

MINI-PS- 12- 24DC/48DC/0.7

2320021

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

MINI-PS- 48- 60DC/24DC/1

2866271

Pcs. /
Pkt.

1

Type

Order No.

MINI-PS- 10- 42AC/15-60DC/3

2320199

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

203

Power supply units and UPS
Redundancy modules

Maximum availability due to redundancy modules
To prevent the effects of errors on the
load in a redundant system and increase the
operational reliability, power supply units
should be decoupled from one another with
a redundancy module. Only by doing this, is
it possible to ensure that an incorrectly connected power supply unit or a short circuit
does not have an effect on the load.
Simple decoupling with STEP and
QUINT DIODE redundancy modules
If the power supply units are decoupled, a
short circuit at the output of one of the
power supply units or in the supply line
from the power supply unit to the diode no
longer has any effect on the load.

204

PHOENIX CONTACT

Decoupling and monitoring with
TRIO DIODE redundancy modules
The redundancy modules check the output voltages of the power supply units, as
well as the wiring up to the redundancy
module itself. Should one of these pathways
short circuit, the load will continue to be
supplied. Cable breaks are also detected and
reported.

Decoupling, monitoring, and closedloop control by means of the QUINT
ORING active redundancy modules
The QUINT ORING active redundancy
modules monitor the entire redundancy solution. They detect critical operating states
and inform the user in good time. For example, faulty wiring or defective cables are reported.

Power supply units and UPS
Redundancy modules

QUINT ORING redundancy module
for maximum system availability
Constant monitoring of input voltage,
output current, and decoupling section
– ACB technology doubles the service life
– Energy savings of 70% by using MOSFETs
over diodes
– Two positive output terminals

ACB technology doubles the service
life
The ACB (Auto Current Balancing) technology provides symmetrical loading of the
power supply units, thereby reducing the
operating temperature. This means up to
double the service life of the redundant system.

Continuous monitoring
QUINT ORING detects critical operating
states within the entire supply path and notifies the operator in good time.
Monitoring
– Power supply unit voltages
– Wiring
– Decoupling section
– Load current

TRIO DIODE redundancy module
– Permanent redundancy monitoring
– Consistent redundancy up to the load
– Flexible: nominal voltages of 12 V DC to
48 V DC

Redundancy module QUINT DIODE
– Rugged design for currents of up to 60 A
– Consistent redundancy up to the load
– Flexible: nominal voltages of 12 V DC to
48 V DC

STEP DIODE redundancy module
– Space-saving: design width of just 18 mm
– Consistent redundancy up to the load
– Flexible: nominal voltages of 5 V DC to
24 V DC

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

205

Power supply units and UPS
Redundancy modules
QUINT ORING, 24 V DC
H
W

D

– Preventive function monitoring: permanent monitoring of the input voltage, output current, and decoupling section
– Continuous redundancy right through to
the load: the use of two Plus output terminal blocks makes it possible to devise a
redundant wiring concept that runs right
through to the load
– Double the service life of the redundant
solution thanks to even load distribution:
the ACB (Auto Current Balancing) technology automatically and symmetrically
distributes the load current to two power
supply units operating in parallel
– Save energy: decoupling is achieved with
MOSFETs and results in energy savings of
up to 70% compared with conventional
diodes
– OVP (Over Voltage Protection): surge
voltages are limited to 30 V

Active redundancy module
24 V DC, 2x 10 A, 1x 20 A


Ex:   
13
14
I...[A]

23
24

IN1 +
IN2 +

+
+

30 V AC/DC
100 mA

Out

-

-

Technical data
Input data
Nominal input voltage range
DC input voltage range
Nominal current
Maximum current
Transient surge protection
Voltage drop, input/output
Max. power dissipation (nominal load)
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Degree of protection / Protection class
Ambient temperature (operation)
Standards/regulations
Insulation voltage: input, output/housing
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
UL approvals

24 V DC
18 V DC ... 28 V DC
2x 10 A (-25 °C ... 60 °C)
1x 20 A (-25 °C ... 60 °C)
2x 15 A (-25°C ... 40°C)
1x 30 A (-25°C ... 40°C)
Varistor
0.1 V (IOUT = 20 A)
2 W (IOUT = 20 A)
0.4 kg / 32 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 4 mm² / 0.2 - 2.5 mm² / 14 - 12
0.2 - 6 mm² / 0.2 - 4 mm² / 10 - 10
IP20 / III
-25 °C ... 70 °C (> 60 °C derating)
500 V
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

Ordering data
Description

Type

Order No.

QUINT-ORING/24DC/2X10/1X20

2320173

Pcs. /
Pkt.

Active redundancy module

206

PHOENIX CONTACT

1

Power supply units and UPS
Redundancy modules
H

H
W

D

W

D

Active redundancy module
24 V DC, 2x 20 A, 1x 40 A

Active redundancy module
24 V DC, 2 x 40 A, 1 x 80 A


Ex:   
13
14
I...[A]

23
24

IN1 +
IN2 +

+
+

13
14

30 V AC/DC
100 mA
I...[A]

23
24

IN1 +
IN2 +

+
+

Out

-

30 V AC/DC
100 mA

Out

-

-

Technical data

-

Technical data

24 V DC
18 V DC ... 28 V DC
2x 20 A (-25 °C ... 60 °C)
1x 40 A (-25 °C ... 60 °C)
2x 26 A (-25°C ... 40°C)
1x 52 A (-25°C ... 40°C)
Varistor
0.2 V (IOUT = 40 A)
8 W (IOUT = 40 A)

24 V DC
18 V DC ... 28 V DC
2x 40 A (-25 °C ... 60 °C)
1x 80 A (-25 °C ... 60 °C)
2x 45 A (-25°C ... 40°C)
1x 90 A (-25°C ... 40°C)
Varistor
0.2 V (IOUT = 80 A)
16 W (IOUT = 80 A)

0.6 kg / 38 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 10 - 10
0.5 - 16 mm² / 0.5 - 16 mm² / 6 - 6
IP20 / III
-25 °C ... 70 °C (> 60 °C derating)

0.9 kg / 66 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.5 - 16 mm² / 0.5 - 16 mm² / 6 - 6
0.5 - 35 mm² / 0.5 - 35 mm² / 2 - 2
IP20 / III
-25 °C ... 70 °C (> 60 °C derating)

500 V
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

500 V
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL applied for

Ordering data

Ordering data

Type

Order No.

QUINT-ORING/24DC/2X20/1X40

2320186

Pcs. /
Pkt.

1

Type

Order No.

QUINT-ORING/24DC/2X40/1X80

2902879

Pcs. /
Pkt.

1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

207

Power supply units and UPS
Redundancy modules
TRIO DIODE, 12 - 24 and 48 V DC
H
D

– Permanent redundancy monitoring:
checking of output voltages of parallelconnected power supplies and of wiring
running to the redundancy module
– Continuous redundancy right through to
the load: the use of two Plus output terminal blocks makes it possible to devise a
redundant wiring concept that runs right
through to the load
– Flexible: nominal voltages of 12 V DC to
48 V DC

W

Redundancy module,
12 - 24 V DC, 2 x 10 A, 1 x 20 A



2x 10 A

IN1+

+

IN2+

+
13
14

–

1x 20 A

IN1+

+

IN2+

+
13
14

–

Technical data
Input data
Nominal input voltage range
DC input voltage range
Nominal current
Maximum current
Transient surge protection
Voltage drop, input/output
Max. power dissipation (nominal load)
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Degree of protection / Protection class
Ambient temperature (operation)
Standards/regulations
Insulation voltage: input, output/housing
Electromagnetic compatibility
Electrical safety, safety transformer
Electronic equipm. for electrical power installations
UL approvals

12 V DC ... 24 V DC
10 V DC ... 30 V DC
2x 10 A (-25°C ... 55°C)
1x 20 A (-25°C ... 55°C)
2x 15 A (-25°C ... 40°C)
1x 30 A (-25°C ... 40°C)
Varistor
Approx. 0.5 V
7 W (IOUT = 10 A)
0.37 kg / 32 x 130 x 115 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.5 - 6 mm² / 0.5 - 4 mm² / 20 - 10
IP20 / III
-25 °C ... 70 °C (> 55° C derating)
500 V
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data
Description

Type

Order No.

TRIO-DIODE/12-24DC/2X10/1X20

2866514

Pcs. /
Pkt.

Redundancy module

208

PHOENIX CONTACT

1

Power supply units and UPS
Redundancy modules
H
D

W

Redundancy module
48 V DC, 2x 10 A, 1x 20 A



2x 10 A

IN1+

+

IN2+

+
13
14

–

1x 20 A

IN1+

+

IN2+

+
13
14

–

Technical data
48 V DC
30 V AC ... 56 V AC
2x 10 A (-25°C ... 55°C)
1x 20 A (-25°C ... 55°C)
2x 15 A (-25°C ... 40°C)
1x 30 A (-25°C ... 40°C)
Varistor
Approx. 0.65 V
14 W (IOUT = 20 A)
0.37 kg / 32 x 130 x 115 mm
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 14
0.5 - 6 mm² / 0.5 - 4 mm² / 20 - 10
IP20 / III
-25 °C ... 70 °C (> 55° C derating)
500 V
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data
Type

Order No.

TRIO-DIODE/48DC/2X10/1X20

2866527

Pcs. /
Pkt.

1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

209

Power supply units and UPS
Redundancy modules
QUINT DIODE and STEP DIODE diode modules

H
W

D

QUINT DIODE, 12 - 24 V and 48 V DC
– Rugged design for currents of up to 60 A
– Continuous redundancy right through to
the load: the use of two Plus output terminal blocks makes it possible to devise a
redundant wiring concept that runs right
through to the load
– Flexible: nominal voltages of 12 V DC to
48 V DC
– Complies with standard EN 60079-15 and
may be installed in a potentially explosive
area

Diode module
12 - 24 V DC, 2x 20 A, 1x 40 A


Ex:   

STEP DIODE
– Space-saving: design width of just 18 mm
– Continuous redundancy right through to
the load: the use of two Plus output terminal blocks makes it possible to devise a
redundant wiring concept that runs right
through to the load
– Flexible: nominal voltages of 5 V DC to
24 V DC

+

+
IN

OUT

+

+

-

-

-

-

Technical data
Input data
Nominal input voltage range
DC input voltage range
Nominal current
Maximum current
Transient surge protection
Voltage drop, input/output
Max. power dissipation (nominal load)
General data
Weight / Dimensions W x H x D
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Degree of protection / Protection class
Ambient temperature (operation)
Standards/regulations
Insulation voltage: input, output/housing
Electromagnetic compatibility
Electrical safety, safety transformer
Electronic equipm. for electrical power installations
UL approvals

12 V DC ... 24 V DC
10 V DC ... 30 V DC
2x 20 A (-25 °C ... 60 °C)
1x 40 A (-25 °C ... 60 °C)
2x 30 A (-25°C ... 40°C)
1x 60 A (-25°C ... 40°C)
Varistor
0.5 V
10 W (IOUT = 20 A)
0.75 kg / 50 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.5 - 16 mm² / 0.5 - 16 mm² / 10 - 6
IP20 / III
-40 °C ... 70 °C (> 60 °C derating)
500 V
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

Ordering data
Description

Type

Order No.

QUINT-DIODE/12-24DC/2X20/1X40

2320157

Pcs. /
Pkt.

Diode module

210

PHOENIX CONTACT

1

Power supply units and UPS
Redundancy modules
H

H
W

D

W

D

Diode module
48 V DC, 2x 20 A, 1x 40 A

Diode module
5 - 24 V DC, 2x 5 A, 1x 10 A


Ex:   



+

+
IN

OUT

1

+

+

-

-

OUT

IN
2

-

-

Technical data

Technical data

48 V DC
30 V DC ... 56 V DC
2x 20 A (-25 °C ... 60 °C)
1x 40 A (-25 °C ... 60 °C)
2x 30 A (-25°C ... 40°C)
1x 60 A (-25°C ... 40°C)
Varistor
0.7 V
14 W (IOUT = 20 A)

5 V DC ... 24 V DC
4.5 V DC ... 30 V DC
2x 5 A (-25°C ... 55°C)
1x 10 A (-25°C ... 55°C)
Transil diode
0.5 V
2.5 W (IOUT = 5 A)

0.75 kg / 50 x 130 x 125 mm
Alignable: 5 mm horizontally, 15 mm next to active components,
50 mm vertically
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.5 - 16 mm² / 0.5 - 16 mm² / 10 - 6
IP20 / III
-40 °C ... 70 °C (> 60 °C derating)

0.1 kg / 18 x 90 x 61 mm
Alignable: 0 mm horizontally, 30 mm vertically

500 V
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

500 V
Conformance with EMC Directive 2004/108/EC
IEC 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
-25 °C ... 70 °C (> 55° C derating)

Ordering data

Ordering data

Type

Order No.

QUINT-DIODE/48DC/2X20/1X40

2320160

Pcs. /
Pkt.

1

Type

Order No.

STEP-DIODE/5-24DC/2X5/1X10

2868606

Pcs. /
Pkt.

1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

211

Power supply units and UPS
Power supply unit accessories
Mounting on S7-300 rail

To supply a SIMATIC® S7-300 control
unit, QUINT POWER 2.5 A, 5 A, and 10 A
are mounted on the S7 rail using a
QUINT-PS-ADAPTER-S7.
No further accessories are required for
fastening.

Technical data
Dimensions W x H x D
Material

Technical data

74 / 130 / 11 mm
Aluminum

104 / 130 / 11 mm
Aluminum

Ordering data
Description
Adapter for S7-300 rail mounting, for:
QUINT-PS/1AC/24DC/3.5
QUINT-PS/1AC/24DC/5
QUINT-PS/3AC/24DC/5
Adapter for S7-300 rail mounting, for:
QUINT-PS/1AC/24DC/10
QUINT-PS/3AC/24DC/10
QUINT-PS/3AC/24DC/20

Ordering data

Type

Order No.

QUINT-PS-ADAPTERS7/1

2938196

Pcs. /
Pkt.

Type

Order No.

QUINT-PS-ADAPTERS7/2

2938206

Pcs. /
Pkt.

1

1

Fans

With the standard power supply mounting position, the temperature range increases by 10 K (max. ambient temperature of
70°C), when the mounting position is rotated, position-dependent derating no longer
applies.
– assembly without tools

Technical data
Dimensions W x H x D
Material

41 / 27 / 42.2 mm
V0 (UL 94)

Ordering data
Description

Type

Order No.

QUINT-PS/FAN/4

2320076

Pcs. /
Pkt.

Fan for QUINT POWER SFB, 24 V DC

212

PHOENIX CONTACT

1

Power supply units and UPS
Power supply unit accessories
Universal wall adapter

Adapter for mounting on even surfaces

Technical data
Dimensions W x H x D
Material

Technical data

52 / 182 / 9 mm
Steel, powder-coated

25 / 130 / 17 mm
Steel, powder-coated

Ordering data
Description

Type

Ordering data
Order No.

Pcs. /
Pkt.

Type

Order No.

UWA 130

2901664

Pcs. /
Pkt.

Universal panel adapter, for direct panel mounting of the
TRIO-PS (from 10 A), QUINT-PS, QUINT-DC-UPS,
QUINT-BUFFER power supply units
UWA 182/52

2938235

1

Universal wall adapter, for direct panel mounting of the
QUINT-PS/1AC/24DC/40 and QUINT-UPS/1AC/1AC/500VA
power supply units
1

Plug-in thermomagnetic circuit
breakers
– Device circuit breakers for protecting
against overcurrents and short circuits
– SFB characteristic curve enables longer
cables and release times < 10 ms
– Maximum ease of maintenance thanks to
the two-piece design
– Further circuit breakers can be found
from page 259 onwards
Can be plugged in, SFB characteristic curve
Technical data
Dimensions W / H / D
Degree of protection

12.3 mm / 90 mm / 77.3 mm
IP30 (Actuation area)

Ordering data
Description

Nominal
current

Pcs. /
Pkt.

Type

Order No.

CB TM1 0.5A SFB P
CB TM1 1A SFB P
CB TM1 2A SFB P
CB TM1 3A SFB P
CB TM1 4A SFB P
CB TM1 5A SFB P
CB TM1 6A SFB P

2800835
2800836
2800837
2800838
2800839
2800840
2800841

1
1
1
1
1
1
1

2800929
2801305

10
10

Thermomagnetic circuit breaker, plug-in, 1-pos.,
signal contact 1 PDT
0.5 A
1A
2A
3A
4A
5A
6A

Accessories
Base element, for accommodating CB TM.../CB E... device circuit
breakers
With push-in connection technology
With screw connection technology

CB 1/6-2/4 PT-BE
CB 1/10-1/10 UT-BE

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

213

Power supply units and UPS
Uninterruptible power supply units for the control cabinet

The intelligent UPS system ensures
maximum system availability
Uninterruptible power supply (UPS) units
continue to deliver power even if the supply
network goes down. An uninterruptible solution consists of the three function units
shown:
– Power supply
– UPS module
– Power storage
QUINT UPS-IQ
IQ technology is the key to an intelligent
power supply solution. The uninterruptible
power supply unit monitors and optimizes
the power storage. Avoid interruptions
when working with the intelligent UPS for
non-stop power.
– SOC (state of charge) keeps you informed of the charging state and remaining runtime of your battery at all times
– SOH (state of health) reports remaining life expectancy of the power storage
device, warns of failure at an early stage
– SOF (state of function) determines
the current performance capability of the
power storage device.

214

PHOENIX CONTACT

Practical example
An industrial PC must be continuously
supplied with 24 V DC.
Previous solution:
The UPS with 3.4 Ah buffers 24 V DC/5 A
for 20 minutes under optimum conditions.
Can the power storage device actually
bridge this time?
Charging state, performance, and remaining runtime of the power storage device are
unknown.
The solution is the QUINT UPS-IQ:
The intelligent UPS determines all relevant power storage device states. This ensures the crucial transparency required to
guarantee the stability of the supply and optimum use of the power storage device at all
times.
The intelligent battery management detects the current charging state of the connected power storage device and uses this
to calculate the remaining runtime.
The QUINT UPS-IQ also indicates
whether the buffer time is actually 20 minutes. As soon as an adjustable threshold value is reached, a warning message is sent via
the floating relay contact, the software or
directly to higher-level controllers. The IPC
continues working for as long as possible

and is shut down before the battery voltage
runs out.

Power supply units and UPS
Uninterruptible power supply units for the control cabinet

IQ technology
The IQ technology is intuitive and provides you with information as soon as it is
required.
– Intelligent battery management with
SOC, SOH, and SOF
– Intelligent battery control
– Intelligent charging
– Data port

Signaling and configuration
The UPS-CONF configuration and management software allows you to monitor
and configure your UPS system. The software can be downloaded free of charge at:
www.phoenixcontact.net/products.
– Flexible adaptation of QUINT UPS-IQ behavior to individual requirements
– Monitoring and data recorder

Communication
The data cables allow you to integrate the
UPS module into your application. You can
therefore benefit from all the advantages of
IQ technology and be kept informed of the
state of your UPS solution. The information
provided by QUINT UPS-IQ can, for example, be forwarded to higher-level controllers
via Ethernet or be implemented directly in
control solutions from Phoenix Contact.

Modular solution
1. Choose your power supply unit, e.g.,
QUINT POWER
2. Choose your UPS module
QUINT UPS-IQ
3. Choose your power storage device:
– UPS-CAP for maximum service life
– UPS-BAT/LI-ION for long service life with
long buffer times
– UPS-BAT/VRLA and VRLA-WTR for
maximum buffer times

UPS with integrated power storage
Particularly space-saving and easy to retrofit, the UPS module and power storage
device are combined in the same housing.
– QUINT UPS: power storage device with
lead AGM technology
– STEP UPS: LiPo-based power storage device
– QUINT BUFFER buffer module: capacitor-based power storage device

UPS with integrated power supply
unit
The UPS module and power supply unit in
a single housing is a space-saving solution.
Only one power storage device is required
to complete the UPS system.
– MINI UPS: for 24 or 12 V DC
– TRIO UPS: for 24 DC

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

215

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Selecting the power storage device for QUINT UPS-IQ
You can always find the ideal solution for
maximum system availability with the new
modular system for uninterruptible power
supply units. The various storage media feature a wide range of different properties:
long service life or a very long buffer time,
no maintenance or use at extreme ambient
temperatures. Whatever your requirements, we have the ideal power storage device.

Your advantages
Fast installation
– Automatic detection of the power storage device by QUINT UPS-IQ
– Tool-free replacement during operation
Maximum availability
– Constant communication with
QUINT UPS-IQ for continuous monitoring and intelligent management
Extremely long service life
– Optimum charging characteristic according to the technology and ambient conditions

Buffer time
(typical)

Temperature

Service life
At 20°C

Service life
At 50°C

Charging cycles
At 20°C

Weight
(standardized)

UPS-CAP…

< 5 min.

-40 ... 60°C

> 20 years

8 years

> 500,000

0.4 kg

UPS-BAT/LI-ION…

> 40 min.

-20 ... 58°C

15 years

2 years

7000

0.45 kg

UPS-BAT/VRLA-WTR…

>5h

-40 ... 60°C

15 years

1.5 years

300

1.3 kg

UPS-BAT/VRLA…

>8h

0 ... 40°C

6 ... 9 years

1 year

250

1 kg

Type

Immediate availability:
All power storage devices leave our
warehouse fully charged

UPS-BAT/VRLA-WTR...
(Valve Regulated Lead Acid/
Wide Temperature Range)
• Maximum buffer times at extreme
temperatures
• Pure lead AGM (Absorbent Glass
Mat) technology
UPS-BAT/VRLA...
(Valve Regulated Lead Acid)
• Maximum buffer times
• Lead AGM (Absorbent Glass Mat) technology

216

PHOENIX CONTACT

UPS-BAT/LI-ION...
• Long service life with long buffer
times
• Lithium-ion technology
UPS-CAP (Capacitor)
• Maximum service life
• Maintenance-free double-layer capacitors

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Selection of power storage devices with capacitors, lithium ion, and pure lead AGM technology
Buffer times for DC UPS modules
Buffer time

Select your UPS-BAT and UPS-CAP for
24 V DC applications here.
Example: 20 A needs to be buffered for
6 minutes.
Solution: UPS-BAT/LI-ION/24DC/120WH

Load current

Seconds
0.2 0.4 1

Hours

Minutes
2

8

16 30

1A
2A
3A
5A
7A
10 A
15 A
20 A
25 A
30 A
35 A
40 A

1

2

3

5

6

7

8

9

10 20 30 40 45 50

1

2

3

5

8

10 15 20 40

1+1

1+1

1+1 1+1 1+1 1+1

1+1 1+1
1+1 1+1
1+1 1+1

1+1
1+1
1+1

1+1

1+1

1+1

1+1
1+1

1+1
1+1
1+1
1+1 1+1
1+1 1+1 1+1 1+1
1+1 1+1 1+1

Buffer times for AC UPS modules
Buffer time

Select your UPS-BAT and UPS-CAP for
120 V AC/230 V AC applications here.
Example: 125 W needs to be buffered for
one hour.
Solution: UPS-BAT/VRLA-WTR/24DC/13AH

Load current
15
35
55
90
125
180
275
400

Minutes

Seconds
0.2 0.4 2

8

15 20 40

W
W
W
W
W
W
W
W

1

2

Hours

3

5

6

7

8

9

10 20 30 40 45 50

1

2

3

5

8

10 15 20 40

1+1 1+1 1+1

1+1
1+1 1+1
1+1 1+1

1+1 1+1
1+1 1+1
1+1
1+1

1+1
1+1
1+1

1+1
1+1
1+1

1+1
1+1

UPS-CAP power storage device

UPS-CAP/24DC/10A/10KJ

UPS-CAP/24DC/20A/20KJ

UPS-BAT/VRLA-WTR power storage
device
UPS-BAT/LI-ION power storage device

UPS-BAT/VRLA-WTR/24DC/13AH

UPS-BAT/VRLA-WTR/24DC/26AH

UPS-BAT/LI-ION/24DC/120WH

Selection of power storage devices with lead AGM technology
Buffer times for DC UPS modules
Buffer time

Select your UPS-BAT for 24 V DC
applications here.
Example: 20 A needs to be buffered for
10 minutes.
Solution: UPS-BAT/VRLA/24DC/7.2AH

Load current

Seconds
0.2 0.4 2

Hours

Minutes
8

2

3

5

6

7

8

9

1A
2A
3A
5A
7A
10 A
15 A
20 A
25 A
30 A
35 A
40 A

10 20 30 40 45 50

1

2

3

1+1 1+1
1+1
1+1 1+1
1+1 1+1 1+1
1+1 1+1 1+1 1+1
1+1 1+1 1+1 1+1

5

8

1+1
1+1 1+1

Buffer times for AC UPS modules
Buffer time

Select your UPS-BAT for 120 V AC/230 V AC
applications here.
Example: 125 W needs to be buffered for
one hour.
Solution: UPS-BAT/VRLA/24DC/12AH

Load current
15 W
35 W
55 W
90 W
125 W
180 W
275 W
400 W

Minutes

Seconds
0.2 0.4 2

8

2

3

UPS-BAT/VRLA power storage device

5

Hours
6

7

8

9

10 20 30 40 45 50

1

2

3

1+1 1+1
1+1

5

8

1+1
1+1 1+1

UPS-BAT/VRLA/24DC/1.3AH

UPS-BAT/VRLA/24DC/3.4AH

UPS-BAT/VRLA/24DC/7.2AH

UPS-BAT/VRLA/24DC/12AH

UPS-BAT/VRLA/24DC/38AH
1+1 … Two rechargeable battery modules of the same capacity are
required in this case.
The data is based on an ambient temperature of 20°C.

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

217

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
QUINT UPS-IQ for DC applications
H
W

D

The UPS module for 24 V DC with output
currents ranging from 5 to 40 A allows you
to create a custom solution combining power supply unit, UPS module, and power
storage device.
Optimum use of the buffer time and preventive monitoring of the power storage
device:
– Detects the current charging state of the
power storage device and calculates the
remaining runtime
– Calculates the current life expectancy of
the power storage device

Uninterruptible power supply,
24 V DC / 24 V DC, 5 A



Substantial power reserve:
– For mains and battery operation
– POWER BOOST static power reserve
– Dynamic power reserve with SFB (Selective Fuse Breaking) technology

Input
DC 24V

Output
DC 24V

Data-Port

13

Confirm

14
23

mC

tmax[min]

24
33

J

I < IN

34
R1

Battery

Extensive signaling and parameterization:
– Floating relay contacts
– Data port
– Parameterization with memory block

Alarm
Bat.Mode
Bat.Charge
Remote

DC 24V

Fast battery charging:
– Adaptive current management charges
the power storage device twice as fast as
before, while simultaneously providing
sufficient energy for the loads.

24V 0.2A

J

R2

Technical data
Input data
Nominal input voltage
DC input voltage range
Max. current consumption
Output data (mains operation)
Nominal output voltage
Output voltage range
Efficiency (typ.)
Output current with convection cooling
- Nominal output current IN (continual)
- SFB technology (12 ms)
- POWER BOOST IBOOST (continual)
Output data (battery operation)
Nominal output voltage
Output voltage range
Output current with convection cooling
- Nominal output current IN (continual)
- SFB technology (15 ms)
- POWER BOOST IBOOST (continual)
Power storage device
Nominal voltage UN
End-of-charge voltage
Nominal capacity range
Max. charging current
Signaling
Signaling
Interfaces
General data
Weight / Dimensions W x H x D
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
Ambient temperature (operation)
Ambient temperature (storage/transport)
Derating
Max. permissible relative humidity (operation)
Standards/regulations
UL approvals

24 V DC
18 V DC ... 30 V DC
9.4 A (Maximum, mains operation)
24 V DC
18 V DC ... 30 V DC
> 98 % (Mains operation, with charged power storage)

5 A (-25 °C ... 60 °C)
30 A (-25 °C ... 60 °C)
7.5 A (-25 °C ... 40 °C)
24 V DC
19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0.5 V DC)

5 A (-25 °C ... 60 °C)
32.5 A (-25 °C ... 60 °C)
7.5 A (-25 °C ... 40 °C)
24 V DC
24 V DC ... 29 V DC (temperature compensated)
0.8 Ah ... 140 Ah
0.2 A ... 1.36 A
LED, relay contact, interface/software
IFS (Interface system data port)
0.5 kg / 35 x 130 x 125 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
-25 °C ... 70 °C
-40 °C ... 85 °C
60 °C ... 70 °C (2.5%/K)
≤ 95 % (25°C, no condensation)
UL/C-UL Recognized UL 60950 , UL Listed UL 508

Ordering data
Description

Type

Order No.

QUINT-UPS/ 24DC/ 24DC/ 5

2320212

Pcs. /
Pkt.

Power supply, uninterruptible

218

PHOENIX CONTACT

1

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
H

H
W

D

H
W

D

Uninterruptible power supply,
24 V DC / 24 V DC, 10 A

Uninterruptible power supply,
24 V DC / 24 V DC, 20 A



Uninterruptible power supply,
24 V DC / 24 V DC, 40 A



Input
DC 24V
13

Confirm

14
23

mC

tmax[min]

24
33

J

I < IN

34
R1

Battery

24V 0.2A

Confirm

Bat.Mode

tmax[min]

Bat.Charge

J

13
14
23

mC

24
33

J

I < IN

34
R1

Battery

J

Technical data

24V 0.2A

Confirm

Bat.Mode

tmax[min]

Bat.Charge

Output
DC 24V

Data-Port

Alarm

Remote

DC 24V

R2

Input
DC 24V

Output
DC 24V

Data-Port

Alarm

Remote

DC 24V



Input
DC 24V

Output
DC 24V

Data-Port

W

D

13

Remote

J

Technical data

R2

Technical data

24 V DC
18 V DC ... 30 V DC
19 A (Maximum, mains operation)

24 V DC
18 V DC ... 30 V DC
32.9 A (Maximum, mains operation)

24 V DC
18 V DC ... 30 V DC
51.9 A (Maximum, mains operation)

24 V DC
18 V DC ... 30 V DC
> 98 % (Mains operation, with charged power storage)

24 V DC
18 V DC ... 30 V DC
> 98 % (Mains operation, with charged power storage)

24 V DC
18 V DC ... 30 V DC
> 99 % (Mains operation, with charged power storage)

10 A (-25 °C ... 60 °C)
60 A (-25 °C ... 60 °C)
15 A (-25 °C ... 40 °C)

20 A (-25 °C ... 60 °C)
120 A (-25 °C ... 60 °C)
26 A (-25 °C ... 40 °C)

40 A (-25 °C ... 50 °C)
215 A (-25 °C ... 60 °C)
45 A (-25 °C ... 40 °C)

24 V DC
19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0.5 V DC)

24 V DC
19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0.5 V DC)

24 V DC
19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0.5 V DC)

10 A (-25 °C ... 60 °C)
65 A (-25 °C ... 60 °C)
15 A (-25 °C ... 40 °C)

20 A (-25 °C ... 60 °C)
120 A (-25 °C ... 60 °C)
27 A (-25 °C ... 40 °C)

40 A (-25 °C ... 60 °C)
215 A (-25 °C ... 60 °C)
45 A (-25 °C ... 40 °C)

24 V DC
24 V DC ... 29 V DC (temperature compensated)
1.3 Ah ... 140 Ah
0.2 A ... 2.88 A

24 V DC
24 V DC ... 29 V DC (temperature compensated)
3 Ah ... 200 Ah
0.2 A ... 5 A

24 V DC
24 V DC ... 29 V DC (temperature compensated)
7 Ah ... 200 Ah
0.2 A ... 5 A

LED, relay contact, interface/software
IFS (Interface system data port)

LED, relay contact, interface/software
IFS (Interface system data port)

LED, relay contact, interface/software
IFS (Interface system data port)

0.5 kg / 35 x 130 x 125 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
-25 °C ... 70 °C
-40 °C ... 85 °C
60 °C ... 70 °C (2.5%/K)
≥ 95 % (25°C, no condensation)

0.6 kg / 40 x 130 x 125 mm
Screw connection
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.2 - 6 mm² / 0.2 - 4 mm² / 12 - 10
0.2 - 4 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
-25 °C ... 70 °C
-40 °C ... 85 °C
60 °C ... 70 °C (2.5%/K)
≤ 95 % (25°C, no condensation)

0.7 kg / 47 x 130 x 125 mm
Screw connection
0.5 - 16 mm² / 0.5 - 16 mm² / 8 - 6
0.5 - 16 mm² / 0.5 - 16 mm² / 8 - 6
0.2 - 4 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
-25 °C ... 70 °C
-40 °C ... 85 °C
60 °C ... 70 °C (2.5%/K)
≤ 95 % (25°C, no condensation)

UL/C-UL Recognized UL 60950 , UL Listed UL 508

UL/C-UL Recognized UL 60950 , UL Listed UL 508

UL/C-UL Recognized UL 60950 , UL Listed UL 508

Ordering data

Ordering data

Type

Order No.

QUINT-UPS/24DC/24DC/10

2320225

Pcs. /
Pkt.

1

Bat.Mode
Bat.Charge

34
R1

Battery
DC 24V

R2

Alarm

24
33

J

I < IN

24V 0.2A

14
23

mC

Ordering data

Type

Order No.

QUINT-UPS/ 24DC/ 24DC/20

2320238

Pcs. /
Pkt.

1

Type

Order No.

QUINT-UPS/24DC/24DC/40

2320241

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

219

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
QUINT UPS-IQ for DC applications
with dual output voltage

H
W

D

The UPS module for two output voltages,
12 and 24 V DC, allows you to create a custom solution combining power supply unit,
UPS module, and power storage device.
– Flexible and space-saving thanks to the
two output voltages in one unit
Optimum use of the buffer time and preventive monitoring of the power storage
device:
– Detects the current charging state of the
power storage device and calculates the
remaining runtime
– Calculates the current life expectancy of
the power storage device

Uninterruptible power supply,
24 V DC/12 V DC, 5 A and 24 V DC, 10 A

Output
DC 12V

Substantial power reserve:
– For mains and battery operation
– POWER BOOST static power reserve
– Dynamic power reserve with SFB (Selective Fuse Breaking) technology

Input
DC 24V

Output
DC 24V

Data-Port
Confirm
tmax[min]

J

I < IN

Extensive signaling and parameterization:
– Floating relay contacts
– Data port
– Parameterization with memory block

Alarm

14
23

mC

Bat.Mode

24
33

Bat.Charge

34
R1

Battery

Remote

DC 24V

Fast battery charging:
– Adaptive current management charges
the power storage device twice as fast as
before, while simultaneously providing
sufficient energy for the loads.

24V 0.2A

13

R2

Technical data
Input data
Nominal input voltage
DC input voltage range
Max. current consumption
Output data (mains operation)
Nominal output voltage
Output voltage range
Efficiency (typ.)
Output current with convection cooling
(Pmax = P12 V + P24 V = 360 W)
- Nominal output current IN (continual)
- SFB technology (15 ms)
- POWER BOOST IBOOST (continual)
Output data (battery operation)
Nominal output voltage
Output voltage range
Output current with convection cooling
(Pmax = P12 V + P24 V = 360 W)
- Nominal output current IN (continual)
- SFB technology (15 ms)
- POWER BOOST IBOOST (continual)
Power storage device
Nominal voltage UN
End-of-charge voltage
Nominal capacity range
Max. charging current
Signaling
Signaling
Interfaces
General data
Weight / Dimensions W x H x D
Connection method
Connection data input/output solid/stranded/AWG

24 V DC
18 V DC ... 30 V DC
16 A
12 V DC
24 V DC
12 V DC
24 V DC
18 V DC ... 30 V DC
(UOUT = UIN - 0.5 V DC)
> 93 % (Mains operation, with
> 98 % (Mains operation, with
charged power storage)
charged power storage)

5 A (-25 °C ... 60 °C)
7.5 A (-25 °C ... 40 °C)
12 V DC
12 V DC
-

5 A (-25 °C ... 60 °C)
7.5 A (-25 °C ... 60 °C)

10 A (-25 °C ... 60 °C)
60 A (-25 °C ... 60 °C)
15 A (-25 °C ... 40 °C)
24 V DC
24 V DC
19.2 V DC ... 27.6 V DC
(UOUT = UBAT - 0.5 V DC)

10 A (-25 °C ... 60 °C)
65 A (-25 °C ... 60 °C)
15 A (-25 °C ... 60 °C)

24 V DC
24 V DC ... 29 V DC (temperature compensated)
1.3 Ah ... 140 Ah
2.88 A
LED, relay contact, interface/software
IFS (Interface system data port)
0.6 kg / 35 x 130 x 125 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12

Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
Ambient temperature (operation)
Derating
Standards/regulations
UL approvals

0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
-25 °C ... 70 °C
60 °C ... 70 °C (2.5%/K)
UL Listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data
Description

Type

Order No.

QUINT-UPS/24DC/12DC/5/24DC/10

2320461

Pcs. /
Pkt.

Power supply, uninterruptible

220

PHOENIX CONTACT

1

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
QUINT UPS-IQ for AC applications
H
W

D

The UPS module for 120 V AC/230 V AC
with 400 W/500 VA power can be combined with all UPS-CAP and UPS-BAT power storage devices.
Optimum use of the buffer time and preventive monitoring of the power storage
device:
– Detects the current charging state of the
power storage device and calculates the
remaining runtime
– Calculates the current life expectancy of
the power storage device

Uninterruptible power supply,
1 AC / 1 AC, 500 VA



Input AC
100..240V

L

L

N

N

PE

PE

USB-Port
Data-Port

24V 0.03A
I
F
S

mC

Simplified startup:
– The UPS can be switched on without a
power supply network

AutonomicStart

Bat.-Mode

J

Power-Boost

Battery

GND
R1
Remote

R2

Maximum energy efficiency:
– Offline operation: 98% efficiency for
charged power storage device
–
–
–
–

Output AC
120/230V

Alarm

Confirm
tmax[min]

DC 24V

Extensive signaling and parameterization:
Switching outputs
USB interface
Data port
Parameterization with memory block

120V 230V

Worldwide use:
– Input voltages from 96 to 264 V AC
– Storage of the level and frequency of the
input voltage, in the event of mains failure,
the output is automatically supplied with
120 V AC/60 Hz or 230 V AC/50 Hz
– Manual voltage pre-selection possible

Technical data
General input data
Input voltage range AC
Frequency range
Activation threshold
Input data
Nominal input voltage
AC input voltage range
Nominal frequency
Max. current consumption (IIN = ICHARGE + IBOOST)
General output data
Nominal power / Apparent power
Derating
Switch-over time
Efficiency (typ.)
Output data (mains operation)
Nominal output voltage
Output voltage range
- Nominal output current IN (continual)
- POWER BOOST IBOOST (continual)
Output data (battery operation)
Nominal output voltage
- Nominal output current IN (continual)
- POWER BOOST IBOOST (5 s)
Power storage device
Nominal voltage UN
End-of-charge voltage
Nominal capacity range
Max. charging current
Signaling
Signaling

80 V AC ... 264 V AC
45 Hz ... 65 Hz
UN ±10%. Can be configured using UPS-CONF software.
120 V AC
120 V AC
80 V AC ... 150 V AC
60 Hz
6.8 A

230 V AC
230 V AC
180 V AC ... 264 V AC
50 Hz
3.7 A

400 W / 500 VA
> 50 °C ... 70 °C (2.5%/K)
< 10 ms
> 98 % (Mains operation)
120 V AC
230 V AC
120 V AC
230 V AC
96 V AC ... 144 V AC
184 V AC ... 276 V AC
4.3 A ( -25 °C ... 70 °C )
2.2 A ( -25 °C ... 70 °C )
5.2 A ( -25 °C ... 70 °C )
2.7 A ( -25 °C ... 70 °C )
120 V AC
230 V AC
120 V AC
230 V AC
4.3 A ( -25 °C ... 50 °C )
2.2 A ( -25 °C ... 50 °C )
5.2 A ( -25 °C ... 50 °C )
2.7 A ( -25 °C ... 50 °C )
24 V DC
25 V DC ... 30 V DC (temperature compensated)
3 Ah ... 200 Ah
0.2 A ... 2 A
LED, active switching outputs, interface/software

Interfaces

IFS (Interface system data port) , MINI-USB type B

General data
Classification according to IEC 62040-3
Weight / Dimensions W x H x D
Connection method
Connection data input/output solid/stranded/AWG

VFD-SS-311
2.2 kg / 125 x 130 x 125 mm
Screw connection
1.5 - 6 mm² / 1.5 - 4 mm² / 18 - 10

Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
Ambient temperature (operation)
Standards/regulations
UL approvals

0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 10
IP20 / I
-25 °C ... 70 °C (> 50°C derating)
UL/C-UL Recognized UL 1778

Ordering data
Description

Type

Order No.

Pcs. /
Pkt.

Power supply, uninterruptible
QUINT-UPS/ 1AC/1AC/500VA

For additional information, visit www.phoenixcontact.net/products

2320270
PHOENIX CONTACT

1

221

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Power storage device for
QUINT UPS-IQ
Maintenance-free CAP UPS
– Dual layer capacitors
– Life expectancy: >20 years (20°C),
>8 years (50°C)
– Communication with QUINT UPS-IQ
– Integrated temperature sensor
– Works reliably, even under extreme ambient temperatures of -40°C to +60°C

H

H
W

D

W

D

Maintenance-free power storage device,
24 V DC, 10 A, 10 kJ

Maintenance-free power storage device,
24 V DC, 20 A, 20 kJ





Input/
Output

Input/
Output

mC

mC

ϑ

ϑ

Technical data
Input data
Nominal input voltage
DC input voltage range
Nominal capacity
Output data
Nominal output voltage
Output voltage range
Output current
Output fuse
Can be connected in parallel / series
Buffer period
General data
Storage medium
Weight / Dimensions W x H x D
Degree of protection / Protection class
Ambient temperature (operation)
Ambient temperature (storage/transport)
Service life
Standards/regulations
UL approvals
GL approvals

Technical data

24 V DC
18 V DC ... 30 V DC
10 kJ

24 V DC
18 V DC ... 30 V DC
20 kJ

24 V DC
22 V DC ... 27 V DC
10 A
1x 25 A (internal)
Yes / No
6 min (1 A) / 33 s (10 A)

24 V DC
22 V DC ... 27 V DC
20 A
2x 25 A (internal)
Yes / No
12 min (1 A) / 33 s (20 A)

Dual layer capacitor
1.7 kg / 126 x 130 x 126 mm
IP20 / III
-40 °C ... 60 °C
-40 °C ... 60 °C
20 Years (20°C)

Dual layer capacitor
2.9 kg / 150 x 130 x 176 mm
IP20 / III
-40 °C ... 60 °C
-40 °C ... 60 °C
20 Years (20°C)

UL Listed UL 508 , UL/C-UL Recognized UL 60950

UL Listed UL 508 , UL/C-UL Recognized UL 60950

GL applied for

GL applied for

Ordering data
Description

Ordering data

Type

Order No.

UPS-CAP/24DC/10A/10KJ

2320377

Pcs. /
Pkt.

Type

Order No.

UPS-CAP/24DC/20A/20KJ

2320380

Pcs. /
Pkt.

Power storage device

222

PHOENIX CONTACT

1

1

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Power storage device for
QUINT UPS-IQ

H
W

D

UPS-BAT/LI-ION for long service life
with long buffer times
– Lithium-ion technology
– Works reliably, even under extreme ambient temperatures of -20 to +58°C
– Communication with QUINT UPS-IQ
– Integrated temperature sensor for optimum charging
– Battery can be changed without tools

120 Wh



Battery
DC 24V

12V

mC

J
12V

Technical data
Input data/output data
Nominal voltage
Nominal capacity
Output current
Output fuse
Can be connected in parallel / series
Buffer period
General data
Storage medium
Weight / Dimensions W x H x D
Degree of protection / Protection class
Ambient temperature (operation)
Service life
Standards/regulations
UL approvals

24 V DC
120 Wh
30 A
1x 30 A
Yes / No
14 min (20 A)
LI-ION, 120 Wh
2.9 kg / 135 x 202 x 110 mm
IP20 / III
-20 °C ... 58 °C
15 Years (20°C)
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data
Description

Type

Order No.

UPS-BAT/LI-ION/24DC/120WH

2320351

Pcs. /
Pkt.

Power storage device

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1

223

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Power storage device for
QUINT UPS-IQ
UPS BAT/VRLA for maximum buffer
times
– Lead AGM (Absorbent Glass Mat) technology
– Ambient temperatures from 0 to +40°C
– Long buffer times for high currents
– Communication with QUINT UPS-IQ
– Integrated temperature sensor for optimum charging
– Battery can be changed without tools

H

H
W

D

1.3 Ah

3.4 Ah


Ex: 



Ex: 

Battery
DC 24V

12V

mC

J

12V

12V

Technical data

Description

Battery
DC 24V

12V

mC

J

Input data/output data
Nominal voltage
Nominal capacity
Output current
Output fuse
Can be connected in parallel / series
Buffer period
General data
Storage medium
Weight / Dimensions W x H x D
Degree of protection / Protection class
Ambient temperature (operation)
Service life
Standards/regulations
UL approvals

W

D

Technical data

24 V DC
1.3 Ah
15 A
1x 15 A
Yes / No
20 min (2 A) / 5 min (5 A)

24 V DC
3.4 Ah
25 A
1x 25 A
Yes / No
4.5 min (20 A) / 3 min (25 A)

Lead rechargeable battery module
1.7 kg / 54 x 157 x 113 mm
IP20 / III
0 °C ... 40 °C
6 Years ... 9 Years (20°C)

Lead rechargeable battery module
3.3 kg / 85 x 191 x 110 mm
IP20 / III
0 °C ... 40 °C
6 Years ... 9 Years (20°C)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , UL/C-UL
Recognized UL 1778 , UL ANSI/ISA-12.12.01 Class I, Division 2,
Groups A, B, C, D (Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , UL/C-UL
Recognized UL 1778 , UL ANSI/ISA-12.12.01 Class I, Division 2,
Groups A, B, C, D (Hazardous Location)

Ordering data

Ordering data

Type

Order No.

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

Power storage device
UPS-BAT/VRLA/24DC/ 1.3AH

Accessories
Mounting set

224

PHOENIX CONTACT

2320296

1

UPS-BAT/VRLA/24DC/ 3.4AH

Accessories

2320306

1

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
H

H
W

D

H
W

D

7.2 Ah

W

D

12 Ah


Ex: 

38 Ah


Ex: 

Battery
DC 24V

12V



Battery
DC 24V

12V

Battery
DC 24V

DC 12V

mC

J

mC

J

mC

J
12V

DC 12V

12V

Technical data

Technical data

Technical data

24 V DC
7.2 Ah
50 A
2x 25 A
Yes / No
10 min (20 A) / 3 min (40 A)

24 V DC
12 Ah
50 A
2x 25 A
Yes / No
22.5 min (20 A) / 9 min (40 A)

24 V DC
38 Ah
50 A
2x 25 A
Yes / No
72 min (20 A) / 35 min (40 A)

Lead rechargeable battery module
5.9 kg / 135 x 202 x 110 mm
IP20 / III
0 °C ... 40 °C
6 Years ... 9 Years (20°C)

Lead rechargeable battery module
8.9 kg / 202 x 202 x 110 mm
IP20 / III
0 °C ... 40 °C
6 Years ... 9 Years (20°C)

Lead rechargeable battery module
26 kg / 330 x 210 x 197 mm
IP20 / III
0 °C ... 40 °C
10 Years ... 12 Years (20°C)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , UL/C-UL
Recognized UL 1778 , UL ANSI/ISA-12.12.01 Class I, Division 2,
Groups A, B, C, D (Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , UL/C-UL
Recognized UL 1778 , UL ANSI/ISA-12.12.01 Class I, Division 2,
Groups A, B, C, D (Hazardous Location)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950 , UL/C-UL
Recognized UL 1778

Ordering data

Ordering data

Ordering data

Type

Order No.

UPS-BAT/VRLA/24DC/ 7.2AH

Accessories

2320319

Pcs. /
Pkt.

1

Type

Order No.

UPS-BAT/VRLA/24DC/12AH

2320322

Pcs. /
Pkt.

1

Type

Order No.

UPS-BAT/VRLA/24DC/38AH

Accessories

Pcs. /
Pkt.

2320335

1

2320788

1

Accessories
BATTERY MOUNTING KIT

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

225

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Power storage device for
QUINT UPS-IQ
BAT/VRLA-WTR UPS for temperatures from -40°C to +60°C
– Pure lead AGM technology
– Communication with QUINT UPS-IQ
– Integrated temperature sensor for optimum charging

Power storage device with wide temperature
range
24 V DC, 13 Ah

Battery
DC 24V

DC 12V

mC

Power storage device with wide temperature
range
24 V DC, 26 Ah

mC

J

J

DC 12V

DC 12V

Technical data
Input data/output data
Nominal voltage
Nominal capacity
Output current
Output fuse
Can be connected in parallel / series
Buffer period
General data
Storage medium
Weight / Dimensions W x H x D
Degree of protection / Protection class
Ambient temperature (operation)
Ambient temperature (storage/transport)
Service life
Standards/regulations
UL approvals
GL approvals

Technical data

24 V DC
13 Ah
50 A
2x 25 A
Yes / No
50 min (10 A) / 10 min (40 A)

24 V DC
26 Ah
50 A
2x 25 A
Yes / No
120 min (10 A) / 30 min (40 A)

Pure lead AGM
10.8 kg / 178 x 168 x 172 mm
IP20 / III
-40 °C ... 60 °C
-40 °C ... 60 °C
10 Years ... 15 Years (20°C)

Pure lead AGM
21.6 kg / 358 x 165 x 169 mm
IP20 / III
-40 °C ... 60 °C
-40 °C ... 60 °C
10 Years ... 15 Years (20°C)

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

GL applied for

GL applied for

Ordering data
Description

Battery
DC 24V

DC 12V

Type

Ordering data
Order No.

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

Power storage device
UPS-BAT/VRLA-WTR/24DC/13AH

2320416

1

Accessories
Mounting set

226

PHOENIX CONTACT

BATTERY MOUNTING KIT

UPS-BAT/VRLA-WTR/24DC/26AH

2320429

1

2320788

1

Accessories
2320788

1

BATTERY MOUNTING KIT

Power supply units and UPS
Uninterruptible power supply units for the control cabinet

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

227

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Configuration software for
QUINT UPS-IQ
The UPS CONF configuration software
can be downloaded free of charge from our
homepage. Remember to order the
IFS-USB-DATACABLE as well in order to
use the software.
Supported operating systems:
– Windows 7 (32 and 64-bit)
– Windows Vista
– Windows XP
Minimum requirements:
– Display: 800 x 600, 256 colors
– Processor: 400 MHz, Pentium processor
or similar
– RAM: 96 MB

Ordering data
Description

Type

Order No.

UPS-CONF

2320403

Pcs. /
Pkt.

Configuration software for QUINT UPS IQ
1

Accessories for QUINT UPS-IQ and
TRIO UPS
IFS-USB-DATACABLE is required for
communication between the uninterruptible power supply and the UPS CONF configuration software.
IFS-CONFSTICK for storing the values
you have configured and transferring them
to other uninterruptible power supplies.
Notes:
1) EMC: Class A product, see page 287

Ordering data
Description

Ordering data

Type

Order No.

IFS-USB-DATACABLE

2320500

Pcs. /
Pkt.

Type

Order No.

IFS-CONFSTICK1)
IFS-CONFSTICK-L

2986122
2901103

Pcs. /
Pkt.

Used for communication between the UPS CONF configuration
software and the QUINT UPS IQ or TRIO UPS uninterruptible
power supply
Cable length: 3 m
Multi-functional memory block for the INTERFACE system
- Flat design
- Tall design

228

PHOENIX CONTACT

1

1
1

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Accessories for QUINT UPS-IQ

IFS-RS232-DATACABLE
– For Modbus communication with the
RS-232 interface
– Connection to the Phoenix Contact
COM server for Ethernet communication
– Communicate directly with higher-level
controllers, such as Phoenix Contact ILC
or RFC, or use as a gateway
IFS-MINI-DIN-DATACABLE
– For direct communication with the ILC
from the Phoenix Contact Inline system

Ordering data
Description

IFS-OPEN-END-DATACABLE
– Open cable for flexible communication
QUINT UPS-IQ function blocks
– For further processing of information
communicated via data cables
– For PC Worx software
– Free download at www.phoenixcontact.net/products

Type

Order No.

IFS-RS232-DATACABLE
IFS-MINI-DIN-DATACABLE
IFS-OPEN-END-DATACABLE

2320490
2320487
2320450

Pcs. /
Pkt.

Data cable for communication between higher-level controllers
and QUINT UPS-IQ uninterruptible power supply units, cable
length: 2 m
Modbus communication
Direct communication
Flexible communication

1
1
1

Mounting set

– For attaching individual battery blocks to
a mounting plate
– Consists of four powder-coated metal
brackets and a fabric lashing strap

Ordering data
Description

Type

Order No.

BATTERY MOUNTING KIT

2320788

Pcs. /
Pkt.

Mounting set

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1

229

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
UPS module with integrated power
storage
QUINT-UPS is very easy to install in existing systems. It's just a case of connecting
a 24 V DC power supply unit upstream and
the reliable UPS solution is complete.
– Advantages of using IQ technology
– Minimal wiring effort
– Maintenance-free power storage device
with lead AGM technology

H

H
D

W

D

W

Notes:

Uninterruptible power supply
with integrated power storage,
24 V DC / 24 V DC, 5 A, 1.3 Ah

The buffer time associated with your solution is dependent on the
load current. Exact details for each uninterruptible power supply
can be found on page 233

Uninterruptible power supply
with integrated power storage,
24 V DC / 24 V DC, 10 A, 3.4 Ah





Input
DC 24V

Input
DC 24V

Output
DC 24V

Data-Port

13

Confirm

14
23

mC

tmax[min]

24
33

J

I < IN
Battery

34
R1

DC 24V

24V 0.2A
Alarm

Confirm

Bat.Mode

tmax[min]

Bat.Charge

13

24
33

J

Battery

34
R1

DC 24V

Bat.Mode
Bat.Charge

Technical data
24 V DC
18 V DC ... 30 V DC
18.6 A (24 V DC)

24 V DC
19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0.5 V DC)

24 V DC
19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0.5 V DC)

Output current
Can be connected in parallel / series
Buffer period
Max. power dissipation (normal mode / buffer mode)

5A
Yes / No
50 min (1 A) / 5 min (5 A)
2.5 W / 3.3 W

10 A
Yes / No
180 min (1 A) / 10 min (10 A)
3.1 W / 6.3 W

Efficiency (typ.)
Signaling
Signaling
Interfaces
General data
Storage medium
Weight / Dimensions W x H x D
Installation position
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Ambient temperature (storage/transport)
Service life
Latest startup

> 97.1 % (with charged power storage device)

> 97.6 % (with charged power storage device)

LED, relay contact, interface/software
IFS (Interface system data port)

LED, relay contact, interface/software
IFS (Interface system data port)

Lead rechargeable battery module 1.3 Ah
2.2 kg / 88 x 138 x 125 mm
horizontal DIN rail NS 35, EN 60715
Can be aligned: horizontal 5 mm, vertical 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 20 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 806493 h
0 °C ... 40 °C
-15 °C ... 40 °C
6 Years ... 9 Years (20°C)
9 Months (20 °C ... 30 °C)
6 Months (30 °C ... 40 °C)

Lead rechargeable battery module, 3.4 Ah
3.8 kg / 120 x 169 x 125 mm
horizontal DIN rail NS 35, EN 60715
Can be aligned: horizontal 5 mm, vertical 50 mm
Plug-in screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 16 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 806493 h
0 °C ... 40 °C
-15 °C ... 40 °C
6 Years ... 9 Years (20°C)
9 Months (20 °C ... 30 °C)
6 Months (30 °C ... 40 °C)

Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL Recognized UL 60950 , UL Listed UL 508

Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL Recognized UL 60950 , UL Listed UL 508

Ordering data
Description

Alarm

R2

24 V DC
18 V DC ... 30 V DC
9.3 A (24 V DC)

Standards/regulations
Electromagnetic compatibility
Electrical safety, safety transformer
Electronic equipm. for electrical power installations
UL approvals

24V 0.2A

Remote

J

R2

Technical data
Input data
Nominal input voltage
DC input voltage range
Max. current consumption
Output data
Nominal output voltage
Output voltage range

14
23

mC

I < IN

Remote

J

Output
DC 24V

Data-Port

Ordering data

Type

Order No.

QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH

2320254

Pcs. /
Pkt.

Type

Order No.

QUINT-UPS/ 24DC/ 24DC/10/3.4AH

2320267

Pcs. /
Pkt.

Power supply, uninterruptible

230

PHOENIX CONTACT

1

1

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Maintenance-free buffer module

Notes:
The buffer time associated with your solution is dependent on the
load current. Exact details for each uninterruptible power supply
can be found on page 233

The buffer module can accommodate failures lasting several seconds.
It combines an electronic switch-over
unit and a capacitor-based power storage
device in the same housing.

H
D

W

Buffer module,
24 V DC / 24 V DC, 40 A


Ex: 

Input

Output

Backup
Threshold

Power
Good
GND

Technical data
Input data
Nominal input voltage
DC input voltage range
Current consumption (idling/charging process/max.)
Connect threshold (fixed, variable)

24 V DC
18 V DC ... 30 V DC
0.1 A / 0.7 A / 44.7 A
< 20 V DC (< 22 V; < 24 V; < 26 V) , (UIN - 1 V)/0.1 s

Output data
Nominal output voltage
Output current
Can be connected in parallel / series
Buffer period
Max. power dissipation (normal mode / buffer mode)

24 V DC (depending on the input voltage)
40 A
Yes / No
0.2 s (40 A) / 8 s (1 A)
8 W / 48 W

Efficiency (typ.)
Signaling
Signaling DC OK
General data
Storage medium
Weight / Dimensions W x H x D
Installation position
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage: input, output/housing
Electromagnetic compatibility
Electrical safety
Electronic equipm. for electrical power installations
UL approvals

> 99 % (with charged power storage device)
LED, active switching output
Electrolytic capacitor
1.1 kg / 64 x 130 x 125 mm
horizontal DIN rail NS 35, EN 60715
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.5 - 16 mm² / 0.5 - 16 mm² / 8 - 6
0.5 - 16 mm² / 0.5 - 16 mm² / 8 - 6
0.2 - 4 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 902725 h
-25 °C ... 80 °C
500 V
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL Recognized UL 60950 , UL Listed UL 508

Ordering data
Description

Type

Order No.

QUINT-BUFFER/24DC/24DC/40

2320393

Pcs. /
Pkt.

Power supply, uninterruptible

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1

231

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
UPS module with integrated power
storage
– Uninterruptible power supply with integrated power storage device

H

H
W

D

W

D

STEP UPS
The STEP BAT power supply unit is included as part of the STEP UPS order. The
STEP BAT can be reordered separately. (See
accessories on this page)
Notes:

Uninterruptible power supply
with integrated rechargeable battery,
24 V DC / 24 V DC, 3 A

With the STEP-UPS/12DC/12DC/4, buffer times are double those
of the STEP-UPS/24DC/24 DC/3. See page 233

Uninterruptible power supply
with integrated rechargeable battery,
12 V DC / 12 V DC, 4 A





Input
DC 24V

Input
DC 12V

Output
DC 24V

tmax
[min]

tmax
[min]

Alarm

mC

Output
DC 12V

Alarm

mC

Bat.- Mode

Bat.- Mode

Bat.- Charge
GND
R1

Battery

Bat.- Charge

Remote

J

Efficiency (typ.)
Signaling
Signaling Power OK
Signaling alarm
Signaling battery charge
Signaling battery mode
General data
Storage medium
Weight / Dimensions W x H x D
Installation position
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Electromagnetic compatibility
Electrical safety, safety transformer
Electronic equipm. for electrical power installations
UL approvals

R2

Technical data

24 V DC
22.5 V DC ... 29.5 V DC
4.1 A (24 V DC)
4.7 A
7 A (slow-blow, internal)

12 V DC
10 V DC ... 16.5 V DC
5.7 A (12 V DC)
6A
7 A (slow-blow, internal)

24 V DC
3A
4 A (0°C ... 35°C)
No / No
50 min (1 A) / 25 min (2 A)
2.7 W / 4.4 W

12 V DC
4A
5 A (0°C ... 35°C)
No / No
100 min (1 A) / 50 min (2 A)
2 W / 3.4 W

> 98 % (Mains operation, with charged power storage)

> 97.4 % (Mains operation, with charged power storage)

LED
LED, active transistor switching output
LED, active transistor switching output
LED, active transistor switching output

LED
LED, active transistor switching output
LED, active transistor switching output
LED, active transistor switching output

Lithium polymer
0.45 kg / 108 x 90 x 61 mm
horizontal DIN rail NS 35, EN 60715
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 1401000 h
0 °C ... 40 °C

Lithium polymer
0.46 kg / 108 x 90 x 61 mm
horizontal DIN rail NS 35, EN 60715
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / III
> 1997000 h
0 °C ... 40 °C

Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL Listed UL 508 , UL/C-UL Recognized UL 60950

Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL Listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data
Description

Remote

J

R2

Technical data
Input data
Nominal input voltage
DC input voltage range
Max. current consumption
Current consumption charging process
Input fuse
Output data
Nominal output voltage
Output current standard operation
Output current POWER BOOST
Can be connected in parallel / series
Buffer period
Max. power dissipation (normal mode / buffer mode)

GND
R1

Battery

Type

Ordering data
Order No.

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

Power supply, uninterruptible
STEP-UPS/24DC/24DC/3

2868703

1

Accessories
Power storage device

232

PHOENIX CONTACT

STEP-BAT/LIPO/18.5DC/1.4AH

STEP-UPS/12DC/12DC/4

2868693

1

2320364

1

Accessories
2320364

1

STEP-BAT/LIPO/18.5DC/1.4AH

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Buffer times for UPS with integrated
power storage
Particularly space-saving and easy to retrofit, the UPS module and power storage
device are combined in the same housing.
The maintenance-free buffer module is now
also available with 40 A load current.

Select your QUINT UPS,
QUINT BUFFER, and STEP UPS here.
Example: 5 A needs to be buffered for
20 minutes.
Solution: QUINT-UPS/24DC/24DC/10/3.4AH

Note: with the STEP-UPS/12DC/12DC/4,
buffer times are double those of the
STEP-UPS/24DC/24 DC/3.

Buffer time
Load current

Minutes

Seconds

0.2

0.4

1

2

8

16

30

1

Hours

2

3

5

6

7

8

9

10

15

20

25

30

40

45

50

1

2

3

0,5 A
1A
2A
3A
5A
7A
10 A
15 A
20 A
25 A
30 A
35 A
40 A
QUINT UPS

QUINT-UPS/24DC/24DC/5/1.3AH

QUINT BUFFER

QUINT-BUFFER/24DC/24DC/40

STEP UPS

STEP-UPS/24DC/24DC/3

QUINT-UPS/24DC/24DC/10/3.4AH

Power storage devices for MINI UPS
and TRIO UPS
The UPS module and power supply unit
are combined in the same housing in a particularly space-saving way. Only one power
storage device is required to complete the
UPS system.

Select your MINI-BAT and QUINT-BAT
for MINI UPS and TRIO UPS here.
Example: 2 A needs to be buffered for
20 minutes.
Solution: MINI-BAT/24DC/1.3AH

MINI UPS
Power storage devices with lead AGM
technology for output voltages of 24 or
12 V DC. Buffer times of up to 50 minutes
with 1 A load current.
Note: with the MINI-DC-UPS/12DC/4,
buffer times are double those of the
MINI-DC-UPS/24DC/2.

TRIO UPS
Power storage devices with lead AGM
technology buffer failures lasting up to
2 hours with 5 A load current.

Hours

Minutes

2

3

5

6

7

8

9

10 20 30 40 45 50

1

2

3

0.5 A
1A
1.5 A
2A
3A
4A
5A
MINI-BAT for MINI-UPS

MINI-BAT/24DC/0.8AH

QUINT-BAT/24DC/7.2AH

MINI-BAT/24DC/1.3AH

QUINT-BAT/24DC/12AH

MINI-BAT for TRIO-UPS

MINI-BAT/24DC/1.3AH
QUINT-BAT/24DC/3.4AH

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

233

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
UPS module with integrated power
supply unit
TRIO UPS
Developed specifically for supplying industrial PCs. Configuration port: freely parameterizable with the UPS CONF configuration software. Configuration stick:
parameterize stick once and transfer to any
number of TRIO UPS units.
The UPS-CONF TRIO (Order No.:
2320348) configuration software can be
downloaded free of charge from our
homepage.

H
W

D

UPS with integrated power supply,
100 - 240 V AC / 24 V DC, 5 A

Notes:
The buffer time associated with your solution is dependent on the
load current. Exact details for each uninterruptible power supply
can be found on page 233


J

Config.-Port

IFS

t...[min]

Confirm
2x 12V

Remote
On/Off

R1

Battery

R2
Alarm
Bat.-Mode
Bat.-Charge

L (+)
N (-)

Output DC
24 V 5 A

PS

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Max. current consumption in normal mode
Input fuse
Reliable backup fuse, circuit breaker
Output data
Nominal output voltage
Output current
Can be connected in parallel / series
Buffer period
Max. power dissipation (normal mode / buffer mode)
Efficiency (typ.)
Signaling
Interfaces
Signaling Power OK
Signaling alarm
Signaling battery charge
Signaling battery mode
General data
Storage medium
Weight / Dimensions W x H x D
Installation position
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety, safety transformer
Electronic equipm. for electrical power installations
UL approvals

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 100 V DC ... 350 V DC
0.95 A / 1.1 A (230 V AC) , 1.7 A / 1.8 A (120 V AC)
6.3 A (slow-blow, internal)
B6 , B10 , B16
24 V DC
5A
No / No
20 min (5 A)
16 W / 4 W
> 88 % (230 V AC, network operation)
IFS (Interface system data port)
LED
LED, active switching output
LED, active switching output
LED, active switching output
External, battery 1.3 Ah / 3.4 Ah / 7.2 Ah / 12 Ah
1.1 kg / 60 x 130 x 118 mm
horizontal DIN rail NS 35, EN 60715
Can be aligned: Horizontally 0 mm, vertically 50 mm
Screw connection
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / I
> 596285 h
-25 °C ... 70 °C (> 55° C derating)
2 kV (Routine test) / 4 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL/C-UL listed UL 508 , UL/C-UL Recognized UL 60950

Ordering data
Description

Type

Order No.

TRIO-UPS/1AC/24DC/ 5

2866611

Pcs. /
Pkt.

Power supply, uninterruptible

234

PHOENIX CONTACT

1

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
UPS module with integrated power
supply unit
MINI-UPS 24 V DC and 12 V DC
The MINI UPS combines the power supply unit and the UPS module in the same
housing in a particularly space-saving way.

H

H
W

D

W

D

Notes:
With the MINI-DC-UPS/12DC/4, buffer times are double those of
the MINI-DC-UPS/24DC/2.
The buffer time associated with your solution is dependent on the
load current. Exact details for each uninterruptible power supply
can be found on page 233

UPS with integrated power supply,
100 - 240 V AC / 24 V DC, 2 A

UPS with integrated power supply,
100 - 240 V AC / 12 V DC, 4 A


Ex: 


Ex: 

t...[min]

R2

-

PS

N(-)

+

R1

+

Alarm
Bat. Mode
Charge

Battery

L(+)

t...[min]

Remote
On/Off

R1

+

+24 V/2A

R2

Alarm
Bat. Mode
Charge

Battery

L(+)
N(-)

-

PS

Technical data
Input data
Nominal input voltage range
Input voltage range AC/DC
Max. current consumption in normal mode

Remote
On/Off

+

+12 V/4A

Technical data

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 100 V DC ... 350 V DC
0.6 A / 0.85 A (230 V AC) , 1.1 A / 1.5 A (120 V AC)

100 V AC ... 240 V AC
85 V AC ... 264 V AC / 100 V DC ... 350 V DC
0.5 A / 0.65 A (230 V AC) , 1.15 A / 1.35 A (120 V AC)

3.15 A (slow-blow, internal)
B6 , B10 , B16

3.15 A (slow-blow, internal)
B6 , B10 , B16

24 V DC (AC input voltage available: 22.5 to 29.5 V DC, AC input
voltage not available: 27.9 to 19.2 V DC)

12 V DC (AC input voltage available: 10 to 16 V DC, AC input voltage
not available: 13.6 to 9.6 V DC)

Output current
Can be connected in parallel / series
Buffer period
Max. power dissipation (idling / normal mode / buffer mode)

2A
No / Yes
20 min (2 A)
3.8 W / 10.1 W / 2.1 W

4A
No / Yes
20 min (4 A)
1.6 W / 10.5 W / 2.6 W

Efficiency (typ.)
Signaling
Signaling Power OK
Signaling alarm
Signaling battery charge
Signaling battery mode
General data
Storage medium
Weight / Dimensions W x H x D
Installation position
Spacing when mounting
Connection method
Input connection data (solid/stranded/AWG)
Output connection data (solid/stranded/AWG)
Signal connection data (solid/stranded/AWG)
Degree of protection / Protection class
MTBF (EN 29500, 40°C)
Ambient temperature (operation)
Standards/regulations
Insulation voltage input/output
Electromagnetic compatibility
Electrical safety, safety transformer
Electronic equipm. for electrical power installations
UL approvals

> 83 %

> 82 %

LED
LED, active switching output
LED, active switching output
LED, active switching output

LED
LED, active switching output
LED, active switching output
LED, active switching output

External, battery 0.8 Ah / 1.3 Ah
0.45 kg / 67.5 x 99 x 107 mm
horizontal DIN rail NS 35, EN 60715
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in COMBICON screw connections
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 728579 h
-25 °C ... 70 °C (> 60 °C derating)

External, rechargeable battery 1.6 Ah / 2.6 Ah
0.45 kg / 67.5 x 99 x 107 mm
horizontal DIN rail NS 35, EN 60715
Can be aligned: Horizontally 0 mm, vertically 50 mm
Plug-in COMBICON screw connections
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
0.2 - 2.5 mm² / 0.2 - 2.5 mm² / 24 - 12
IP20 / II (in an enclosed control cabinet)
> 753179 h
-25 °C ... 70 °C (> 60 °C derating)

2 kV (routine test) / 4 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

2 kV (routine test) / 4 kV (type test)
Conformance with EMC Directive 2004/108/EC
EN 60950-1/VDE 0805 (SELV)
EN 50178/VDE 0160 (PELV)
UL Listed UL 508 , UL/C-UL Recognized UL 60950 ,
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D
(Hazardous Location)

Input fuse
Reliable backup fuse, circuit breaker
Output data
Nominal output voltage

Ordering data
Description

Type

Ordering data
Order No.

Pcs. /
Pkt.

Type

Order No.

MINI-DC-UPS/12DC/4

2866598

Pcs. /
Pkt.

Power supply, uninterruptible
MINI-DC-UPS/24DC/2

2866640

1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1

235

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Power storage device for TRIO UPS
H
D

MINI-BAT, QUINT-BAT
MINI-BAT and QUINT BAT for maximum
buffer times
– Lead AGM (Absorbent Glass Mat) technology
– Ambient temperatures from 0 to +40°C

W

Power storage, 24 V DC, 1.3 Ah
for TRIO UPS and MINI UPS 2 A

Ex: 

Technical data
Input data/output data
Nominal input voltage
Nominal capacity
Nominal output voltage
Output current
Can be connected in parallel / series
General data
Weight / Dimensions W x H x D
Degree of protection / Protection class
Ambient temperature (operation)
Service life
Latest startup

24 V DC
1.3 Ah
24 V DC
15 A
Yes / No
1.7 kg / 52 x 130 x 110 mm
IP20 / III
0 °C ... 40 °C
6 Years ... 9 Years (20 °C)
9 Months (20 °C ... 30 °C)
6 Months (30 °C ... 40 °C)

Ordering data
Description

Type

Order No.

MINI-BAT/24DC/1.3AH

2866417

Pcs. /
Pkt.

Battery module

236

PHOENIX CONTACT

1

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
H
D

H
W

H
W

D

Power storage, 24 V DC, 3.4 Ah
for TRIO UPS

D

Power storage, 24 V DC, 7.2 Ah
for TRIO UPS

BSH 

W

Power storage, 24 V DC, 12 Ah
for TRIO UPS





Technical data

Technical data

Technical data

24 V DC
3.4 Ah
24 V DC
25 A
Yes / No

24 V DC
7.2 Ah
24 V DC
50 A
Yes / No

24 V DC
12 Ah
24 V DC
50 A
Yes / No

3.5 kg / 112 x 145 x 123 mm
IP20 / III
0 °C ... 40 °C
6 Years ... 9 Years (20 °C)
9 Months (20 °C ... 30 °C)
6 Months (30 °C ... 40 °C)

6 kg / 164 x 156 x 110 mm
IP20 / III
0 °C ... 40 °C
6 Years ... 9 Years (20 °C)
9 Months (20 °C ... 30 °C)
6 Months (30 °C ... 40 °C)

9 kg / 231 x 156 x 110 mm
IP20 / III
0 °C ... 40 °C
6 Years ... 9 Years (20 °C)
9 Months (20 °C ... 30 °C)
6 Months (30 °C ... 40 °C)

Ordering data

Ordering data

Type

Order No.

QUINT-BAT/24DC/ 3.4AH

2866349

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

QUINT-BAT/24DC/ 7.2AH

2866352

Pcs. /
Pkt.

1

Type

Order No.

QUINT-BAT/24DC/12AH

2866365

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

237

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
Power storage device for MINI UPS

Notes:
The buffer time associated with your solution is dependent on the
load current. Exact details for each uninterruptible power supply
can be found on page 233

MINI-BAT
MINI-BAT for maximum buffer times
– Lead AGM (Absorbent Glass Mat) technology
– Ambient temperatures from 0 to +40°C

H
D

W

Power storage, 24 V DC, 0.8 Ah
for MINI UPS 2 A

Ex: 

Technical data
Input data/output data
Nominal input voltage
Nominal capacity
Nominal output voltage
Output current
Can be connected in parallel / series
General data
Weight / Dimensions W x H x D
Degree of protection / Protection class
Ambient temperature (operation)
Service life
Latest startup

24 V DC
0.8 Ah
24 V DC
5A
Yes / No
0.9 kg / 67.5 x 99 x 107 mm
IP20 / III
0 °C ... 40 °C
4 Years (20 °C)
6 Months (20 °C ... 30 °C)
3 Months (30 °C ... 40 °C)

Ordering data
Description

Type

Order No.

MINI-BAT/24DC/0.8AH

2866666

Pcs. /
Pkt.

Battery module

238

PHOENIX CONTACT

1

Power supply units and UPS
Uninterruptible power supply units for the control cabinet
H
D

H
W

H
W

D

Power storage, 24 V DC, 1.3 Ah
for TRIO UPS and MINI UPS 2 A

D

Power storage 12 V DC, 1.6 Ah
for MINI UPS 4 A

Ex: 

Power storage 12 V DC, 2.6 Ah
for MINI UPS 4 A

Ex: 

Technical data

W

Ex: 

Technical data

Technical data

24 V DC
1.3 Ah
24 V DC
15 A
Yes / No

12 V DC
1.6 Ah
12 V DC
10 A
Yes / No

12 V DC
2.6 Ah
12 V DC
15 A
Yes / No

1.7 kg / 52 x 130 x 110 mm
IP20 / III
0 °C ... 40 °C
6 Years ... 9 Years (20 °C)
9 Months (20 °C ... 30 °C)
6 Months (30 °C ... 40 °C)

0.9 kg / 67.5 x 99 x 107 mm
IP20 / III
0 °C ... 40 °C
4 Years (20 °C)
6 Months (20 °C ... 30 °C)
3 Months (30 °C ... 40 °C)

1.7 kg / 52 x 130 x 110 mm
IP20 / III
0 °C ... 40 °C
6 Years ... 9 Years (20 °C)
9 Months (20 °C ... 30 °C)
6 Months (30 °C ... 40 °C)

Ordering data

Ordering data

Type

Order No.

MINI-BAT/24DC/1.3AH

2866417

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

MINI-BAT/12DC/1.6AH

2866572

Pcs. /
Pkt.

1

Type

Order No.

MINI-BAT/12DC/2.6AH

2866569

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

Pcs. /
Pkt.

1

239

Power supply units and UPS
Uninterruptible power supply units for 19" racks/towers

Constant power supply and improved
power quality
UPS devices play an important role in ensuring reliable power quality. They bridge
power failures and remove other mains
faults such as:
– Under voltages or surge voltages
– High-frequency noise
– Frequency fluctuations
– Harmonics

240

PHOENIX CONTACT

Class VFI-SS-111 UPS devices according to IEC 62040-3
The UPS devices are class VFI-SS-111 single-phase, uninterruptible power supply
units. The connected loads are protected
against any faults on the mains side. Double
conversion technology permanently supplies loads with an output voltage/frequency
that is independent of the mains input.

Extensive configuration options:
Configure your UPS system according to
your requirements and the operating environment.
UPS-CP devices can be configured directly
via the control panel, even with no external
power supply, provided the batteries are
charged:
– Quick status check via LED and illuminated LCD control panel
– Controlled computer shutdown by means
of additional software
– Remote access via web browser with
SNMP network card
Complete and extend your UPS system:
– DIN rails offer the option of installing the
UPS-CP devices in 19" racks
– All devices can be extended with SNMP
network cards or relay cards

Power supply units and UPS
Uninterruptible power supply units for 19" racks/towers

Long battery life
The special charge control of the UPS-CP
devices ensures ripple-free DC voltage
without higher-level AC currents.

Integrated safety cut-off
If required the UPS-CP devices can be integrated in a safety concept via a two-pos.
connection.

Easy battery replacement
Batteries can be easily replaced during operation and when integrated. This is true for
all UPS devices and battery modules.

Stand-alone or 19" rack installation
possible
Depending on the application, the control
panel on the UPS-CP devices can be rotated
90° for optimum display clarity.

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

241

Power supply units and UPS
Uninterruptible power supply units for 19" racks/towers
In order to select the ideal UPS, the power requirement of the connected loads and
the required bridging time must be known.
The diagrams illustrated can be used to select
the appropriate UPS.
By adding external battery units, correspondingly longer bridging times can be
achieved.
For the assignment and maximum possible
number of external battery units, please refer
to the table on the right.

... BAT-1KVA-P1
... BAT-1KVA-P2
... BAT-2/3KVA-P3

UPS-CP-...

... BAT-2/3KVA-P4
... BAT-4.5/6KVA-P5
...1KVA/240AC

Max. 2

Max. 1

—

—

—

...2KVA/240AC

—

—

Max. 4

Max. 2

—

...3KVA/240AC

—

—

Max. 4

Max. 2

—

...4.5KVA/240AC

—

—

—

—

Max. 5

...6KVA/240AC

—

—

—

—

Max. 5

Time [min.]

UPS-CP-1kVA/240AC
1000

1

100

2
10

1

1 = 2xP1 or 1xP2
2 = 1xP2
3 = Without additional battery

50

100

150

200

250

3

300

350

400

450

500

550

600

650

700

750

800

Nominal real power [W]

Time [min.]

UPS-CP-2kVA/240AC
1000

1
2
3

100

4

10

1 = 4xP3 or 2xP4
2 = 3xP3
3 = 2xP3 or 1xP4
4 = 1xP3
5 = Without additional battery

1

100

200

300

400

500

600

5
700

800

900

1000 1100 1200 1300 1400 1500 1600
Nominal real power [W]

242

PHOENIX CONTACT

Power supply units and UPS
Uninterruptible power supply units for 19" racks/towers

Time [min.]

UPS-CP-3kVA/240AC
1000

1
2

100

3

10

4
1 = 4xP3 or 2xP4
2 = 3xP3
3 = 2xP3 or 1xP4
4 = 1xP3
5 = Without additional battery

1

100

300

500

5

700

900

1100

1300

1500

1700

1900

2100

2300

Nominal real power [W]

Time [min.]

UPS-CP-4.5kVA/240AC
10000

1

1000

2

3

100

1 = 5xP5
2 = 4xP5
3 = 3xP5
4 = 2xP5
5 = 1xP5

10

1

100

400

4
5
700

1000

1300

1600

1900

2200

2500

2800

3100

Nominal real power [W]

Time [min.]

UPS-CP-6kVA/240AC
10000

1

1000

2

3

100

1 = 5xP5
2 = 4xP5
3 = 3xP5
4 = 2xP5
5 = 1xP5

10

1

100

500

4
5
900

1300

1700

2100

2500

2900

3300

3700

4100

Nominal real power [W]

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

243

Power supply units and UPS
Uninterruptible power supply units for 19" racks/towers
UPS devices

– Class VFI-SS-111 single-phase UPS (according to IEC 62040-3)
– Double conversion technology for maximum voltage quality
– Use as rack (19") or tower device with rotatable control panel
– Hot-swappable battery replacement on
the front
– Long battery life thanks to ripple-free
charging
– Mains-independent output voltage
– Comprehensive accessories for enhanced
functions
– Supports a variety of operating systems

1 kVA nominal power

2 kVA nominal power

Total width 483 mm

Total width 483 mm

Notes:
1) EMC: Class A product, see page 287

=

Input

Output

=

Input

Technical data
Common characteristics
Apparent power
Nominal power (real power)
Power factor
UPS topology
Classification
UPS input side
AC input voltage range
AC frequency range
Nominal input current
Power factor (cos phi)
Current distortion (THDi)
UPS output side
Output voltage range
Nominal output current
AC frequency range
Battery system
Battery type
Bridging time
Charging time
Type of battery replacement
General data
Ambient temperature (operation)
Ambient temperature (storage/transport)
Degree of protection
Height unit
Design
Depth
Permissible humidity (operation)
Noise level
Weight

Output

Technical data

1000 VA
800 W
0.8
Double conversion technology
VFI-SS-111

2000 VA
1600 W
0.8
Double conversion technology
VFI-SS-111

160 ... 288 V AC
50 Hz ... 60 Hz +/-5 Hz (automatic recognition)

160 ... 288 V AC
50 Hz ... 60 Hz +/-5 Hz (automatic recognition)

3.8 A
0.99 (with linear load)
< 6 % (at full load)

8A
0.99 (with linear load)
< 6 % (at full load)

230 V AC ±1% (200/208/220/230/240 V AC adjustable)

230 V AC ±1% (200/208/220/230/240 V AC adjustable)

4.35 A
50 / 60 Hz (automatic recognition)

8.7 A
50 / 60 Hz (automatic recognition)

VRLA
≥ 6 min
4 h (90% charge)
Hot-swappable

VRLA
≥ 6 min (Nominal load, in addition)
4 h (90% charge)
Hot-swappable

0 °C ... 40 °C
0 °C ... 45 °C
IP20
2 HU
19" rack/fixed housing
490.00 mm
0 % ... 90 % (no condensation)
50.00 dB(A)
19.00 kg

0 °C ... 40 °C
0 °C ... 45 °C
IP20
2 HU
19" rack/fixed housing
680.00 mm
0 % ... 90 % (no condensation)
50.00 dB(A)
30.00 kg

Ordering data
Description

=
=

Ordering data

Type

Order No.

UPS-CP-1KVA/240AC1)

2800274

Pcs. /
Pkt.

Pcs. /
Pkt.

Type

Order No.

UPS-CP-2KVA/240AC1)

2800275

1

UPS compact
1

Accessories

Accessories

Optional power storage device

DIN rail
For 19" rack installation

244

PHOENIX CONTACT

UPS-CP-BAT-1KVA-P1
UPS-CP-BAT-1KVA-P2

2800280
2800281

1
1

UPS-CP-BAT-2/3KVA-P3
UPS-CP-BAT-2/3KVA-P4

2800283
2800284

1
1

UPS-CP-19"MR

2800288

1

UPS-CP-19"MR

2800288

1

Power supply units and UPS
Uninterruptible power supply units for 19" racks/towers

3 kVA nominal power

4.5 kVA nominal power

Total width 483 mm

Input

6 kVA nominal power

Total width 483 mm

=

Total width 483 mm

Output

=

Input

Technical data

=

Output

=

Input

Technical data

=

Output

=

Technical data

3000 VA
2400 W
0.8
Double conversion technology
VFI-SS-111

4500 VA
4050 W
0.9
Double conversion technology
VFI-SS-111

6000 VA
5400 W
0.9
Double conversion technology
VFI-SS-111

160 ... 288 V AC
50 Hz ... 60 Hz +/-5 Hz (automatic recognition)

160 ... 280 V AC
50 Hz ... 60 Hz +/-5 Hz (automatic recognition)

160 ... 280 V AC
50 Hz ... 60 Hz +/-5 Hz (automatic recognition)

11.5 A
0.99 (with linear load)
< 6 % (at full load)

21.9 A
0.99 (with linear load)
< 6 % (at full load)

28.48 A
0.99 (with linear load)
< 6 % (at full load)

230 V AC ±1% (200/208/220/230/240 V AC adjustable)

230 V AC ±1% (200/208/220/230/240 V AC adjustable)

230 V AC ±1% (200/208/220/230/240 V AC adjustable)

13.04 A
50 / 60 Hz (automatic recognition)

19.57 A
50 / 60 Hz (automatic recognition)

26.09 A
50 / 60 Hz (automatic recognition)

VRLA
≥ 5 min (Nominal load, in addition)
4 h (90% charge)
Hot-swappable

9 min (Full load)
-

6 min (Full load)
-

0 °C ... 40 °C
0 °C ... 45 °C
IP20
2 HU
19" rack/fixed housing
680.00 mm
0 % ... 90 % (no condensation)
50.00 dB(A)
33.00 kg

0 °C ... 40 °C
0 °C ... 45 °C
IP20
2 HU
19" rack/fixed housing
680.00 mm
0 % ... 90 % (no condensation)
50.00 dB(A)
22.00 kg

0 °C ... 40 °C
0 °C ... 45 °C
IP20
2 HU
19" rack/fixed housing
680.00 mm
0 % ... 90 % (no condensation)
50.00 dB(A)
22.00 kg

Ordering data

Ordering data

Type

Order No.

UPS-CP-3KVA/240AC1)

2800276

Pcs. /
Pkt.

1

Ordering data

Type

Order No.

UPS-CP-4.5KVA/240AC1)

2800277

Accessories

Pcs. /
Pkt.

1

Order No.

UPS-CP-6KVA/240AC1)

2800278

1

2800288

1

Accessories

UPS-CP-BAT-2/3KVA-P3
UPS-CP-BAT-2/3KVA-P4

2800283
2800284

1
1

UPS-CP-19"MR

2800288

1

UPS-CP-19"MR

Pcs. /
Pkt.

Type

Accessories

2800288

1

UPS-CP-19"MR

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

245

Power supply units and UPS
Uninterruptible power supply units for 19" racks/towers
Power storage devices

– Power storage for increasing the duration
of the bridging
– Hot-swappable battery replacement
– Error-free connection thanks to adapted
connection method

For UPS-CP-1KVA, 19 minutes (nominal load)

For UPS-CP-1KVA, 36 minutes (nominal load)

Total width 483 mm

Total width 483 mm

Technical data
Battery system
Battery type
Battery capacity
Bridging time
Bridging time
Charging time
Type of battery replacement
General data
Ambient temperature (operation)
Ambient temperature (storage/transport)
Degree of protection
Height unit
Design
Depth
Weight

Technical data

VRLA
14.40 Ah
19 min (Nominal load, in addition)
4 h (90% charge)
Hot-swappable

VRLA
28.80 Ah
36 min (Nominal load, in addition)
4 h (90% charge)
Hot-swappable

0 °C ... 40 °C
0 °C ... 45 °C
IP20
2 HU
19" rack/fixed housing
680.00 mm
29.00 kg

0 °C ... 40 °C
0 °C ... 45 °C
IP20
2 HU
19" rack/fixed housing
680.00 mm
44.00 kg

Ordering data
Description

Type

Ordering data
Order No.

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

Optional power storage device
UPS-CP-BAT-1KVA-P1

2800280

1

UPS-CP-BAT-1KVA-P2

Accessories
DIN rail
For 19" rack installation

246

PHOENIX CONTACT

UPS-CP-19"MR

2800281

1

2800288

1

Accessories
2800288

1

UPS-CP-19"MR

Power supply units and UPS
Uninterruptible power supply units for 19" racks/towers

For UPS-CP-2KVA, 8 minutes (nominal load)
For UPS-CP-3KVA, 5 minutes (nominal load)

Total width 483 mm

For UPS-CP-2KVA, 19 minutes (nominal load)
For UPS-CP-3KVA, 12 minutes (nominal load)

For UPS-CP-4.5KVA, 10 minutes (nominal load)
For UPS-CP-6KVA, 8 minutes (nominal load)

Total width 483 mm

Total width 483 mm

Technical data

Technical data

Technical data

VRLA
7.20 Ah
8 min (nominal load - 2 kVA)
5 min (nominal load - 3 kVA)
4 h (90% charge)
Hot-swappable

VRLA
14.40 Ah
19 min (nominal load - 2 kVA)
12 min (nominal load - 3 kVA)
4 h (90% charge)
Hot-swappable

VRLA
7.20 Ah
9 min (Nominal load - 4.5 kVA)
6 min (nominal load - 6 kVA)
4 h (90% charge)
Hot-swappable

0 °C ... 40 °C
0 °C ... 45 °C
IP20
2 HU
19" rack/fixed housing
680.00 mm
29.00 kg

0 °C ... 40 °C
0 °C ... 45 °C
IP20
2 HU
19" rack/fixed housing
680.00 mm
44.00 kg

0 °C ... 40 °C
0 °C ... 45 °C
IP20
3 HU
19" rack/fixed housing
680.00 mm
70.00 kg

Ordering data
Type

Ordering data
Order No.

UPS-CP-BAT-2/3KVA-P3

2800283

Pcs. /
Pkt.

1

Type

Order No.

UPS-CP-BAT-2/3KVA-P4

Accessories
UPS-CP-19"MR

Ordering data

2800284

Pcs. /
Pkt.

1

Type

UPS-CP-BAT-4.5/6KVA-P5

Accessories
2800288

1

UPS-CP-19"MR

Order No.

Pcs. /
Pkt.

2800285

1

2800288

1

Accessories
2800288

1

UPS-CP-19"MR

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

247

Power supply units and UPS
Uninterruptible power supply units for 19" racks/towers
UPS accessories

– SNMP network cards for UPS remote
control and monitoring
– Relay cards with extended signal outputs
for control functions
– External bypass modules for bypassing the
UPS during servicing
– Multiple socket strips for connecting additional loads
– Redundancy modules for parallel connection of UPS devices to increase the reliability of the supply

SNMP interface adapter card

6-way relay card

Notes:
1) EMC: Class A product, see page 287
Total width 20 mm

Total width 20 mm

Technical data

Technical data

Electrical data
Input
Nominal voltage
Nominal current
Power supply connection

... CARD

... CARD E

9 V AC ... 30 V AC
120 mA
PCB connector

9 V AC ... 30 V AC
120 mA
PCB connector

PCB connector

Output
Nominal voltage
Nominal current

-

-

40 V DC
max. 25 mA

Load connection

RJ 45

RJ45, RJ12, Mini-DIN

Screw terminal block

Available interfaces
General data
Ambient temperature (operation)
Ambient temperature (storage/transport)
Degree of protection
Design

Ethernet / 1x RS-232

Ethernet / 3x RS-232

Screw terminal block

0 °C ... 60 °C
0 °C ... 45 °C
Slot card

0 °C ... 60 °C
0 °C ... 45 °C
Slot card

0 °C ... 40 °C
0 °C ... 45 °C
Slot card

Ordering data

Ordering data

Description

Type

Order No.

Network card
Basic version (RJ45)
Extended version (RJ45, Modbus, AUX port)

UPS-SNMP-CARD1)
UPS-SNMP-CARD E1)

2800289
2800290

Pcs. /
Pkt.

248

PHOENIX CONTACT

2800550

Order No.

UPS-6REL1)

2800287

Pcs. /
Pkt.

1
1

Relay card
6-way relay card
External bypass module
For UPS-CP 1 - 3 kVA
For UPS-CP 4.5 and 6 kVA
Socket strip
With 9 x 10 A IEC outputs
With 4 x 16 A IEC outputs
With 5 x 16 A + 9 x 10 A IEC outputs
Redundancy module
For two units
For three units
RCCMD software license
UPS-CP RCCMD LICENSEKEY

Type

1

1

Power supply units and UPS
Uninterruptible power supply units for 19" racks/towers

External bypass module

Multiple socket strip

Total width 482.6 mm

Module for parallel/redundancy operation with
external bypass

Total width 483 mm

Technical data

Total width 483 mm

Technical data

Technical data

... 1/2/3KVA

... 4.5/6KVA

... 9X10A-IEC

... 4X16A-IEC

... 5X16A/9X10A-IEC

... 32A-4.5/6KV

240 V AC
max. 16 A
Socket C20 - IEC 60320

240 V AC
max. 32 A
Cable L/N/PE

240 V AC
max. 16 A
C20 IEC 60320

240 V AC
max. 16 A
C20 IEC 60320

240 V AC
max. 32 A
Terminal block base - L/N/PE

240 V AC
240 V AC
max. 32 A
max. 63 A
Cable L/N/PE; 2.8 m; open ends Cable L/N/PE; 2.8 m; open ends

240 V AC
16 A (thermal fuse)

240 V AC
32 A

240 V AC
32 A

Cable L/N/PE; 2.8 m; open ends

240 V AC
16 A (thermal
fuse)
4 x C19 IEC 60320

240 V AC
16 A (10 A/thermal fuse)

6 x C13/10 A - IEC 60320

240 V AC
10 A (thermal
fuse)
9 x C13 IEC 60320

5 x C19/16 A - IEC 60320

Cable L/N/PE; 2.8 m; open ends Cable L/N/PE; 2.8 m; open ends

-

-

-

-

-

0 °C ... 40 °C
0 °C ... 45 °C
IP20
19" rack patch module

0 °C ... 40 °C
0 °C ... 45 °C
IP20
19" rack patch module

0 °C ... 40 °C
0 °C ... 45 °C
IP20
19" rack patch module

0 °C ... 40 °C
0 °C ... 45 °C
IP20
19" rack patch module

0 °C ... 40 °C
0 °C ... 45 °C
IP20
19" rack patch module

0 °C ... 40 °C
0 °C ... 45 °C
IP20
19" rack patch
module

Ordering data

0 °C ... 40 °C
0 °C ... 45 °C
IP20
19" rack patch
module

Ordering data

Type

Order No.

UPS-CP-BP-1/2/3KVA
UPS-CP-BP-4.5/6KVA

2800291
2800292

Pcs. /
Pkt.

... 63A-4.5/6KV

240 V AC
63 A

Ordering data

Type

Order No.

UPS-CP-MS-9X10A-IEC
UPS-CP-MS-4X16A-IEC
UPS-CP-MS-5X16A/9X10A-IEC

2800293
2800294
2800296

Pcs. /
Pkt.

Type

Order No.

UPS-CP-PU-240AC/32A-4.5/6KV
UPS-CP-PU-240AC/63A-4.5/6KV

2800297
2800298

Pcs. /
Pkt.

1
1
1
1
1

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

1
1

249

250

PHOENIX CONTACT

Protective devices
High-grade device circuit breakers offer safety for your systems
Device circuit breakers are a key factor in
high system availability. In the event of overload and short-circuit currents, they selectively shut down the faulty circuit.

Introduction

252

Product overview

254

CB series device circuit breakers
Electronic circuit breakers

256

Thermomagnetic circuit breakers

213

Device circuit breaker board

262

Device circuit breakers
Thermomagnetic circuit breakers

263

Thermal circuit breakers

264

Electronic circuit breakers

268

PHOENIX CONTACT

251

Protective devices
Introduction to protective devices

Branch out
The device circuit breakers provide reliable protection even if your systems involve
long cable paths. Together with the SFB
technology* of the QUINT POWER power
supply units, the special SFB trigger characteristic of the CB device circuit breakers ensures fast shutdown in the event of an error.
This combination offers maximum protection against overload and short-circuit currents.
*SFB = Selective fuse breaking, selective
shutdown
Individual adaptation
You can pre-wire your systems with base
elements and individually equip them with
protective plugs on site. The device circuit
breakers can also be quickly adapted to accommodate necessary changes in your system. Should you change a load, simply replace the relevant protective plug. Various
tripping methods, characteristic curves, and
nominal currents are available depending on
the application.

252

PHOENIX CONTACT

Modular extension
It couldn't be easier. Enhance your system
with additional device circuit breakers in no
time at all. You can bridge the power distribution, remote signaling or even the auxiliary voltage for electronic circuit breakers
without this resulting in significant wiring
costs. The uniform, plug-in housing concept
as well as the bridgeability of the base elements simplify installation.
Device circuit breaker board
The multi-channel circuit breaker boards
are used in standard production machines
or in control and process technology, for
example.
Central potential distribution minimizes the
time and effort that has to be spent on installation. The boards are very versatile in
application, as each one is populated with
thermomagnetic circuit breakers individually.

Protective devices
Introduction to protective devices

Latching
You can quickly and easily remove the
plugs from the base element. The new latching ensures a secure fit in harsh environments and where there are vibrations in the
installation environment. It holds the plug in
place in the base element.

Coding
Straightforward coding means that components can be mounted on the base element according to individual requirements
without any errors.

SFB trigger characteristic
Thermomagnetic device circuit breakers
with the SFB trigger characteristic* provide
maximum overcurrent protection – even in
large systems with long cable paths.

Bridge
With the unique bridge system from our
standard range, the device circuit breakers
can be combined easily as per your requirements. Potentials of the same type can be
connected quickly and safely.

Variable connection technologies
You can choose base elements with either
push-in or screw connection technology.

Device circuit breaker board
The multi-channel device circuit breaker
boards are available with 4, 8 or 12 channels.

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

253

Protective devices
Product overview
Circuit breakers: electronic

Selective

Thermal

CB E1...

EC-E1 + EC-E4

ECP-E

ECP ...

TCP ...32V

TCP ...

Page 256

Page 268

Page 270

Page 273

Page 264

Page 265

EC-E

ECP-E2

Page 269

Page 271

ECP-E3
Page 272

Circuit breakers: thermomagnetic

CB-TM1...SFB

CB-TM1...M1 P

CB-TM2...M1 P

UT 6-TMC M

TMC 1 F1 100 0,2A

TMCP 1 F1 300 0,2A

Page 259

Page 260

Page 260

Page 263

Page 266

Page 266

CB-TM2...SFB

CB-TM1...F1 P

CB-TM2...F1 P

Page 259

Page 260

Page 260

Board

CBB TM 04...P-PT
Page 262

CBB TM 08...P-PT
Page 262

CBB TM 12...P-PT
Page 262

254

PHOENIX CONTACT

Protective devices
Selection guide
CB device circuit breakers

CB E1...

CB-TM1...

TCP ...

Page 256

Page 259

Page 265

Device circuit breaker board

CBB TM...P-PT
Page 262

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

255

Protective devices
Device circuit breakers
Plug-in electronic circuit breakers

90
12,3

77,3

45

1 N/O contact
40,7

– Device circuit breakers for protecting
against voltage dips caused by overloads
and short circuits
– Integrated active current limitation
– Remote control possible
– Maximum ease of maintenance thanks to
the two-piece design
– Snap-in function for secure hold and easy
removal
– Plug coding possible
– Narrow design

The figure shows the complete module consisting of a base
element and connector

Total width 12.3 mm

Technical data
Rated data
Operating voltage
Nominal current IN
Disconnection
Switch-off time
Switch off
Current limitation
General data
Temperature range
Degree of protection
Standards/regulations

24 V DC
Depends on the selected item version
See trigger characteristic
typ. 1.25 x IN
active
0 °C ... 50 °C (without condensation)
IP30 (Actuation area)
UL 2367 / UL 508 / CSA 22.2 / EN 61000-6-3

Ordering data
Nominal current

Description

Pcs. /
Pkt.

Type

Order No.

CB E1 24DC/1A NO P
CB E1 24DC/2A NO P
CB E1 24DC/3A NO P
CB E1 24DC/4A NO P
CB E1 24DC/6A NO P

2800901
2800902
2800903
2800904
2800905

1
1
1
1
1

Electronic circuit breaker, 1-pos.
1A
2A
3A
4A
6A
8A
10 A

Accessories
Bridge plug, 0 volt distribution
CB PT BRIDGE

2801014

1

Base element
With push-in connection technology
With screw connection technology

CB 1/6-2/4 PT-BE
CB 1/10-1/10 UT-BE

2800929
2801305

10
10

Plug-in bridge, for cross connections in the bridge shaft

For FBS ..., see page 258

1000

Switching time [s]

100
10
1
0,1
0,01

0

1

2

3
Multiples of IN

Trigger characteristic

256

PHOENIX CONTACT

Protective devices
Device circuit breakers

1 N/C contact

1 x Reset IN + 1 x Status OUT

Total width 12.3 mm

1 x Control IN + 1 x Status OUT

Total width 12.3 mm

Technical data

Total width 12.3 mm

Technical data

Technical data

24 V DC
Depends on the selected item version

24 V DC
Depends on the selected item version

24 V DC
Depends on the selected item version

See trigger characteristic
typ. 1.25 x IN
active

See trigger characteristic
typ. 1.25 x IN
active

See trigger characteristic
typ. 1.25 x IN
active

0 °C ... 50 °C (without condensation)
IP30 (Actuation area)
UL 2367 / UL 508 / CSA 22.2 / EN 61000-6-3

0 °C ... 50 °C (without condensation)
IP30 (Actuation area)
UL 2367 / UL 508 / CSA 22.2 / EN 61000-6-3

0 °C ... 50 °C (without condensation)
IP30 (Actuation area)
UL 2367 / UL 508 / CSA 22.2 / EN 61000-6-3

Ordering data

Ordering data

Type

Order No.

CB E1 24DC/1A NC P
CB E1 24DC/2A NC P
CB E1 24DC/3A NC P
CB E1 24DC/4A NC P
CB E1 24DC/6A NC P

2800915
2800916
2800917
2800918
2800919

Pcs. /
Pkt.

1
1
1
1
1

Type

Order No.

CB E1 24DC/1A S-R P
CB E1 24DC/2A S-R P
CB E1 24DC/3A S-R P
CB E1 24DC/4A S-R P
CB E1 24DC/6A S-R P
CB E1 24DC/8A S-R P
CB E1 24DC/10A S-R P

2800908
2800909
2800910
2800911
2800912
2800913
2800914

Accessories

Pcs. /
Pkt.

1
1
1
1
1
1
1

2801014

1

CB 1/6-2/4 PT-BE
CB 1/10-1/10 UT-BE

2800929
2801305

10
10

Order No.

CB E1 24DC/1A S-C P
CB E1 24DC/2A S-C P
CB E1 24DC/3A S-C P
CB E1 24DC/4A S-C P
CB E1 24DC/6A S-C P
CB E1 24DC/8A S-C P
CB E1 24DC/10A S-C P

2800922
2800923
2800924
2800925
2800926
2800927
2800928

1
1
1
1
1
1
1

CB PT BRIDGE

2801014

1

CB 1/6-2/4 PT-BE
CB 1/10-1/10 UT-BE

2800929
2801305

10
10

Accessories

CB PT BRIDGE

2801014

1

CB 1/6-2/4 PT-BE
CB 1/10-1/10 UT-BE

2800929
2801305

10
10

For FBS ..., see page 258

Pcs. /
Pkt.

Type

Accessories

CB PT BRIDGE

For FBS ..., see page 258

Ordering data

For FBS ..., see page 258

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

257

Protective devices
Device circuit breakers
Base element and plug-in bridges

Base elements
– For accommodating CB TM/CB E.
device circuit breakers
– Rail-mountable module
– With bridge shafts
– Systematic structure with 1-channel base
elements possible
Notes:
Can be loaded with up to 41 A if two bridges are connected for the
supply.

1-pos. with push-in connection,
input 1 x 6 mm2/output 2 x 4 mm2

1-pos. with screw connection,
input 1 x 10 mm2/output 1 x 10 mm2

Total width 12.3 mm

Total width 12.3 mm

Technical data
Rated surge voltage
General data
Dimensions W / H / D
Connection method
Temperature range
Degree of protection
Inflammability class according to UL 94
Standards/regulations

Technical data

4 kV

2.5 kV

12.3 mm / 90 mm / 46.7 mm
Push-in connection
-30 °C ... 60 °C
IP30 (Actuation area)
V0
IEC 60947-7-1

12.3 mm / 90.8 mm / 70 mm
Screw connection
-30 °C ... 60 °C
IP30 (Actuation area)
V0
UL 1059

Ordering data
Description

Type

-

Ordering data
Order No.

Pcs. /
Pkt.

2800929

10

Type

Order No.

Pcs. /
Pkt.

2801305

10

Base element
CB 1/6-2/4 PT-BE

CB 1/10-1/10 UT-BE

Accessories
Plug-in bridge, red

Plug-in bridge, blue

Plug-in bridge, gray

258

PHOENIX CONTACT

Number of positions
2
3
4
5
10
20
50
Number of positions
2
3
4
5
10
20
50
Number of positions
2
3
4
5
10

Accessories

FBS 2-6
FBS 3-6
FBS 4-6
FBS 5-6
FBS 10-6
FBS 20-6
FBS 50-6

3030336
3030242
3030255
3030349
3030271
3030365
3032224

50
50
50
50
10
10
10

FBS 2-6
FBS 3-6
FBS 4-6
FBS 5-6
FBS 10-6
FBS 20-6
FBS 50-6

3030336
3030242
3030255
3030349
3030271
3030365
3032224

50
50
50
50
10
10
10

FBS 2-6 BU
FBS 3-6 BU
FBS 4-6 BU
FBS 5-6 BU
FBS 10-6 BU
FBS 20-6 BU
FBS 50-6 BU

3036932
3036945
3036958
3036961
3032198
3032208
3032211

50
50
50
50
10
10
10

FBS 2-6 BU
FBS 3-6 BU
FBS 4-6 BU
FBS 5-6 BU
FBS 10-6 BU
FBS 20-6 BU
FBS 50-6 BU

3036932
3036945
3036958
3036961
3032198
3032208
3032211

50
50
50
50
10
10
10

FBS 2-6 GY
FBS 3-6 GY
FBS 4-6 GY
FBS 5-6 GY
FBS 10-6 GY

3032237
3032240
3032279
3032266
3032253

50
50
50
50
10

FBS 2-6 GY
FBS 3-6 GY
FBS 4-6 GY
FBS 5-6 GY
FBS 10-6 GY

3032237
3032240
3032279
3032266
3032253

50
50
50
50
10

Protective devices
Device circuit breakers
Plug-in thermomagnetic circuit
breakers

90
12,3

77,3

45

Can be plugged in, SFB characteristic curve
40,7

– Device circuit breakers for protecting
against voltage dips caused by overloads
and short circuits
– SFB characteristic curve enables longer
cables and release times < 10 ms
– Maximum ease of maintenance thanks to
the two-piece design
– Snap-in function for secure hold and easy
removal
– Plug coding possible
– Narrow design

The figure shows the complete module consisting of a base
element and connector


Total width 12.3 mm

Technical data
Rated data
Rated voltage
Rated voltage
Rated current In
Disconnection
Switch-off time
Fuse type
Rated short-circuit switching capacity Icn
Cycles, max.
General data
Temperature range
Degree of protection
Standards/regulations

IEC
UL/CUL
240 V AC
277 V AC
50 V DC
50 V DC
Depends on the selected item version
See trigger characteristic
SFB
300 A (240 V AC) / 600 A (50 V DC)
6000 (at 1 x In)
-30 °C ... 60 °C
IP30 (Actuation area)
EN 60934 / UL 1077 / UL 508 / CSA 22.2

Ordering data
Description

Nominal current

Thermomagnetic circuit breaker, plug-in, 1-pos., signal contact
1 PDT
0.5 A
1A
2A
3A
4A
5A
6A
8A
10 A
12 A
16 A
Thermomagnetic circuit breaker, plug-in, 2-pos., signal contact
1 PDT
0.5 A
1A
2A
3A
4A
5A
6A
8A
10 A
12 A
16 A

Pcs. /
Pkt.

Type

Order No.

CB TM1 0.5A SFB P
CB TM1 1A SFB P
CB TM1 2A SFB P
CB TM1 3A SFB P
CB TM1 4A SFB P
CB TM1 5A SFB P
CB TM1 6A SFB P
CB TM1 8A SFB P
CB TM1 10A SFB P
CB TM1 12A SFB P
CB TM1 16A SFB P

2800835
2800836
2800837
2800838
2800839
2800840
2800841
2800842
2800843
2800844
2800845

1
1
1
1
1
1
1
1
1
1
1

CB TM2 0.5A SFB P
CB TM2 1A SFB P
CB TM2 2A SFB P
CB TM2 3A SFB P
CB TM2 4A SFB P
CB TM2 5A SFB P
CB TM2 6A SFB P
CB TM2 8A SFB P
CB TM2 10A SFB P
CB TM2 12A SFB P
CB TM2 16A SFB P

2800868
2800869
2800870
2800871
2800872
2800873
2800874
2800875
2800876
2800877
2800878

1
1
1
1
1
1
1
1
1
1
1

CB PT BRIDGE

2801014

1

CB 1/6-2/4 PT-BE
CB 1/10-1/10 UT-BE

2800929
2801305

10
10

Switching time [s]

Accessories
10000

0,5...6 A

8...16 A

1000

Bridge plug, 0 volt distribution
Base element
With push-in connection technology
With screw connection technology

100
10
1
0,1
0,01
0,001

1 2 4 6 10 20 40 100

2 4 6 10 20 40 100

Multiples of IN

Trigger characteristic in the DC range

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

259

Protective devices
Device circuit breakers
Plug-in thermomagnetic circuit
breakers

90
12,3

77,3

45

Can be plugged in, M1 characteristic curve,
1-pos.

40,7

– Device circuit breakers for protecting
against voltage dips caused by overloads
and short circuits
– Medium-blow and fast-blow tripping characteristics
– 1 and 2-pos. circuit breakers
– Maximum ease of maintenance thanks to
the two-piece design
– Snap-in function for secure hold and easy
removal
– Plug coding possible
– Narrow design

The figure shows the complete module consisting of a base
element and connector


Total width 12.3 mm

Technical data
Rated data
Rated voltage
Rated voltage
Rated current In
Disconnection
Switch-off time
Fuse type
Rated short-circuit switching capacity Icn
Cycles, max.
General data
Temperature range
Degree of protection
Standards/regulations

IEC
UL/CUL
240 V AC
277 V AC
50 V DC
50 V DC
Depends on the selected item version
See trigger characteristic
normal blow
300 A (240 V AC) / 600 A (50 V DC)
6000 (at 1 x In)
-30 °C ... 60 °C
IP30 (Actuation area)
EN 60934 / UL 1077 / UL 508 / CSA 22.2

Ordering data
Description

Nominal current

Pcs. /
Pkt.

Type

Order No.

CB TM1 0.5A M1 P
CB TM1 1A M1 P
CB TM1 2A M1 P
CB TM1 3A M1 P
CB TM1 4A M1 P
CB TM1 5A M1 P
CB TM1 6A M1 P
CB TM1 8A M1 P
CB TM1 10A M1 P
CB TM1 12A M1 P
CB TM1 16A M1 P

2800846
2800847
2800848
2800849
2800850
2800851
2800852
2800853
2800854
2800855
2800856

1
1
1
1
1
1
1
1
1
1
1

CB PT BRIDGE

2801014

1

CB 1/6-2/4 PT-BE
CB 1/10-1/10 UT-BE

2800929
2801305

10
10

Thermomagnetic circuit breaker, plug-in, signal contact 1 PDT
0.5 A
1A
2A
3A
4A
5A
6A
8A
10 A
12 A
16 A

Accessories
Bridge plug, 0 volt distribution

Switching time [s]

Base element
With push-in connection technology
With screw connection technology

10000

0,5...6 A

8...16 A

1000
100
10
1
0,1
0,01
0,001

1 2 4 6 10 20 40 100

2 4 6 10 20 40 100

Multiples of IN
Trigger characteristic
Gray: DC range, blue: AC range

260

PHOENIX CONTACT

Protective devices
Device circuit breakers

Can be plugged in, M1 characteristic curve,
2-pos.

Can be plugged in, F1 characteristic curve,
1-pos.

Can be plugged in, F1 characteristic curve,
2-pos.







Total width 24.6 mm

Total width 12.3 mm

Total width 24.6 mm

Technical data

Technical data

Technical data

IEC
UL/CUL
240 V AC
277 V AC
80 V DC
80 V DC
Depends on the selected item version

IEC
UL/CUL
240 V AC
277 V AC
50 V DC
50 V DC
Depends on the selected item version

IEC
UL/CUL
240 V AC
277 V AC
80 V DC
80 V DC
Depends on the selected item version

See trigger characteristic
normal blow
400 A (240 V AC) / 600 A (80 V DC)
6000 (240 V AC/1 x In)

See trigger characteristic
fast blow
300 A (240 V AC) / 600 A (50 V DC)
6000 (at 1 x In)

See trigger characteristic
fast blow
400 A (240 V AC) / 600 A (80 V DC)
6000 (240 V AC/1 x In)

-30 °C ... 60 °C
IP30 (Actuation area)
EN 60934 / UL 1077 / UL 508 / CSA 22.2

-30 °C ... 60 °C
IP30 (Actuation area)
EN 60934 / UL 1077 / UL 508 / CSA 22.2

-30 °C ... 60 °C
IP30 (Actuation area)
EN 60934 / UL 1077 / UL 508 / CSA 22.2

Ordering data

Ordering data

Type

Order No.

CB TM2 0.5A M1 P
CB TM2 1A M1 P
CB TM2 2A M1 P
CB TM2 3A M1 P
CB TM2 4A M1 P
CB TM2 5A M1 P
CB TM2 6A M1 P
CB TM2 8A M1 P
CB TM2 10A M1 P
CB TM2 12A M1 P
CB TM2 16A M1 P

2800879
2800880
2800881
2800882
2800883
2800884
2800885
2800886
2800887
2800888
2800889

Pcs. /
Pkt.

1
1
1
1
1
1
1
1
1
1
1

Type

Order No.

CB TM1 0.5A F1 P
CB TM1 1A F1 P
CB TM1 2A F1 P
CB TM1 3A F1 P
CB TM1 4A F1 P
CB TM1 5A F1 P
CB TM1 6A F1 P
CB TM1 8A F1 P
CB TM1 10A F1 P
CB TM1 12A F1 P
CB TM1 16A F1 P

2800857
2800858
2800859
2800860
2800861
2800862
2800863
2800864
2800865
2800866
2800867

1
1
1
1
1
1
1
1
1
1
1

1

Order No.

CB TM2 0.5A F1 P
CB TM2 1A F1 P
CB TM2 2A F1 P
CB TM2 3A F1 P
CB TM2 4A F1 P
CB TM2 5A F1 P
CB TM2 6A F1 P
CB TM2 8A F1 P
CB TM2 10A F1 P
CB TM2 12A F1 P
CB TM2 16A F1 P

2800890
2800891
2800892
2800893
2800894
2800895
2800896
2800897
2800898
2800899
2800900

1
1
1
1
1
1
1
1
1
1
1

CB PT BRIDGE

2801014

1

CB 1/6-2/4 PT-BE
CB 1/10-1/10 UT-BE

2800929
2801305

10
10

CB 1/6-2/4 PT-BE
CB 1/10-1/10 UT-BE

2800929
2801305

10
10

0,5...6 A

8...16 A

1000
100
10

Accessories

CB PT BRIDGE

2801014

1

CB 1/6-2/4 PT-BE
CB 1/10-1/10 UT-BE

2800929
2801305

10
10

Switching time [s]

2801014

10000

0,5...6 A

8...16 A

1000
100
10

10000

10
1

0,1

0,1

0,1

0,01

0,01

0,01

2 4 6 10 20 40 100
Multiples of IN

Trigger characteristic
Gray: DC range, blue: AC range

0,001

1 2 4 6 10 20 40 100

2 4 6 10 20 40 100

Multiples of IN
Trigger characteristic in the DC range

For additional information, visit www.phoenixcontact.net/products

8...16 A

100

1

1 2 4 6 10 20 40 100

0,5...6 A

1000

1

0,001

Pcs. /
Pkt.

Type

Accessories

CB PT BRIDGE

Switching time [s]

Pcs. /
Pkt.

Switching time [s]

Accessories

10000

Ordering data

0,001

1 2 4 6 10 20 40 100

2 4 6 10 20 40 100

Multiples of IN
Trigger characteristic in the DC range

PHOENIX CONTACT

261

Protective devices
Device circuit breakers
Device circuit breaker board

Notes:

H

The board is supplied without a plug.

W

D

Only type CB TM1... plugs can be used.
For dimensional drawings, see www.phoenixcontact.net/products

DIN-rail mountable

Technical data
Rated data
Rated voltage

– Reduced installation time thanks to multichannel device circuit breaker board
(4/8/12 channels)
– Space savings of up to 35% thanks to compact design
– Fuse protection of up to 12 A per channel
provides best possible protection for connected loads
– Up to 5 loads can be protected simultaneously with the additional terminal points
– Integrated group remote signaling ensures
that you are always kept informed
– High current carrying capacity of the
board supports supply of up to 60 A
– Maximum overcurrent protection across
long cable paths thanks to device circuit
breakers with SFB trigger characteristic

262

PHOENIX CONTACT

CBB TM 04

CBB TM 08

CBB TM 12

Main circuit
Remote indication circuit

24 V DC
24 V DC

24 V DC
24 V DC

24 V DC
24 V DC

Complete main circuit
Main circuit per channel
Remote indication circuit

48 A DC
12 A DC
1 A DC
50 V DC
0.5 kV

60 A DC
12 A DC
1 A DC
50 V DC
0.5 kV

60 A DC
12 A DC
1 A DC
50 V DC
0.5 kV

118.5 mm /
127.8 mm /
72 mm
-30 °C ... 60 °C
(At max. 45 A,
see derating)

185.5 mm /
127.8 mm /
72 mm
-30 °C ... 60 °C
(At In 60 A)

252.5 mm / 127.8 mm / 72 mm

Rated current In

Rated insulation voltage Ui
Rated surge voltage
General data
Dimensions W / H / D

Ambient temperature (operation)

Degree of protection

-30 °C ... 60 °C (At In 60 A)

IP20 (Terminal blocks and fuse holders) IP00 (PCB)

Test standards

DIN EN 50178

Ordering data
Description

Type

Order No.

Device circuit breaker board, for accommodating device circuit
breakers
With 4 channels
With 8 channels
With 12 channels

CBB TM 04 2X2RC P-PT
CBB TM 08 2X4RC P-PT
CBB TM 12 2X6RC P-PT

2801481
2801482
2801483

Pcs. /
Pkt.

1
1
1

Protective devices
Device circuit breakers
Thermomagnetic circuit breaker
UT 6-TMC ...

DIN-rail mountable


Total width 12.3 mm

Technical data

– Thermomagnetic circuit breakers feature
a compact design, large-surface labeling
options, and a double plug-in bridge shaft
– They can be integrated into the CLIPLINE
complete system via the plug-in bridge
shaft
– 12.3 mm compact design
– High level of system availability thanks to
their reclosure function and clear status
display
– Eleven nominal current levels can be selected from 0.5 A to 16 A
– Clear assignment of the relevant circuit
breaker thanks to the large center labeling
area
A complete data sheet is available to
download for each product at www.phoenixcontact.net/products.

Rated data
Rated voltage
Rated voltage
Rated current In
Disconnection
Switch-off time
Fuse type
Rated short-circuit switching capacity Icn
Cycles, max.
General data
Dimensions W / H / D
Connection method
Connection data solid / stranded / AWG
Stranded conductor cross section with ferrule
Temperature range
Degree of protection

IEC
UL/CUL
240 V AC
240 V AC
28 V DC
28 V DC
Depends on the selected item version

12.3 mm / 85.5 mm / 89.5 mm
Screw connection
0.2 ... 10 mm² / 0.2 ... 10 mm² / 24 - 8
0.25 ... 6 mm²
-30 °C ... 60 °C
IP40 (Actuation area) / IP20 (Connection area)

Standards/regulations

EN 60934 / UL 1077 / CSA 22.2

See trigger characteristic
Normal blow (M1)
200 A (240 V AC) / 400 A (28 V DC)
6000 (at 1 x In)

Ordering data
Description

Nominal current

Pcs. /
Pkt.

Type

Order No.

UT 6-TMC M 0,5A
UT 6-TMC M 1A
UT 6-TMC M 2A
UT 6-TMC M 4A
UT 6-TMC M 5A
UT 6-TMC M 6A
UT 6-TMC M 8A
UT 6-TMC M 10A
UT 6-TMC M 12A
UT 6-TMC M 15A
UT 6-TMC M 16A

0916603
0916604
0916605
0916606
0916607
0916608
0916609
0916610
0916611
0916612
0916613

6
6
6
6
6
6
6
6
6
6
6

3030336
3030242
3030255
3030349
3030271
3030365
3047345
1205066

50
50
50
50
10
10
10
10

Thermomagnetic circuit breaker, for mounting on NS 35...
0.5 A
1A
2A
4A
5A
6A
8A
10 A
12 A
15 A
16 A

Accessories

Switching time [s]

Plug-in bridge, red

10000

<7A

7A

1000

Number of positions
2
3
4
5
10
20

Warning label, for UT series
Screwdriver

FBS 2-6
FBS 3-6
FBS 4-6
FBS 5-6
FBS 10-6
FBS 20-6
WS UT 6
SZS 1,0X4,0 VDE

Lateral groove labeling

For UC-TM 12 or ZB 12, see page 111

100
10
1
0,1
0,01
0,001

1

2

4 6 8 12 20

50 1 2

4 6 8 12 20 50
Multiples of IN

Trigger characteristic

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

263

Protective devices
Device circuit breakers
TCP thermal circuit breaker

Notes:
Attention: The reset button must not be obstructed. During installation, please leave enough room for using button.
For additional technical data, drawings, and accessories, please
visit www.phoenixcontact.net/products.
You can find a wide selection of fuse terminal blocks in Catalog 3,
Modular terminal blocks
1)

If the fuse is faulty, the downstream circuit is not off load.

For fuse holder

Total width 6 mm

Technical data

– Plug-in thermal miniature circuit breakers
combine the protective mechanism of an
auto flat-type fuse with the advantages of
a circuit breaker
– In the event of an error, the time-sensitive
search for a suitable replacement fuse is
eliminated thanks to the reclosure function
– The area of application extends to the
protection of integrated circuits in all
battery and onboard systems with up to
32 V DC
– Fits in all fuse holders designed for flattype fuse inserts according to
ISO 8820-3 (DIN 72581-3)
– A version with screw or spring-cage connection is used as a basic terminal block
You can find more fuse terminal
blocks in Catalog 3, Modular terminal
blocks.

Rated data
Rated voltage
Rated current In
Disconnection
Switch-off time
Fuse type
Rated short-circuit switching capacity Icn
General data
Dimensions W / H / D
Height
Temperature range
Degree of protection

IEC
32 V DC
Depends on the selected item version
See trigger characteristic
Slow-blow
≤ 50 A (300 switch-offs)
6 mm / 20 mm / 31.2 mm
17 mm
-40 °C ... 85 °C
IP30 (Actuation area)

Ordering data
Description

Nominal
current

One-pos., thermal circuit breaker, for fuse holders in acc. with
ISO 8820-3
5A
7.5 A
10 A
15 A
20 A
25 A
30 A
40 A

Type

Order No.

Pcs. /
Pkt.

TCP 5/DC32V
TCP 7,5/DC32V
TCP 10/DC32V
TCP 15/DC32V
TCP 20/DC32V
TCP 25/DC32V
TCP 30/DC32V
TCP 40/DC32V

0700005
0700007
0700010
0700015
0700020
0700025
0700030
0700040

50
50
50
50
50
50
50
50

Accessories
Fuse terminal block, with spring-cage connection, for mounting
on NS 35...
With LED for 12 V DC, 1.7 mA

ST 4-FSI/C
ST 4-FSI/C-LED 12

3036372
3036495

50
50

With LED for 24 V DC, 1.9 mA1)

ST 4-FSI/C-LED 24

3036505

50

UK 6-FSI/C
UK 6-FSI/C-LED12
UK 6-FSI/C-LED24

3118203
3001925
3001938

50
50
50

Fuse terminal block, for mounting on NS 32... or NS 35...

Switching time [s]

With LED for 12 V DC
With LED for 24 V DC, 1.9 mA1)

10

4

10

TCP/DC32V
5A

10

4

3

10

2

10

10

-40°C

10

TCP/DC32V
7,5 A - 30 A

3

2

-40°C

10

+23°C

+23°C
1
+85°C
0,1
0,4 1 2

1

4

10

20

+85°C
0,1
0,4 1 2

4

10 20

Current [A]

Trigger characteristic

264

PHOENIX CONTACT

Protective devices
Device circuit breakers
TCP thermal circuit breaker

Notes:
Note:
When mounted in rows, the nominal current of the devices can be
transmitted only at 80% or must be correspondingly overdimensioned.
For additional technical data, drawings, and accessories, please
visit www.phoenixcontact.net/products.

Can be plugged into a fuse terminal block


Total width 8.2 mm

Technical data

– The reclosable thermal circuit breaker is
available in nine nominal current levels
ranging from 0.25 to 10 A
– The integrated switching function enables
immediate reclosure and thus ensures the
availability of the system
– Compact design
– A version with screw or spring-cage connection is used as a basic terminal block
– Potential distribution possible by means
of bridges
A complete data sheet is available to
download for each product at
www.phoenixcontact.net/products.

Rated data
Rated voltage
Rated voltage
Rated current In
Disconnection
Switch-off time
Fuse type
General data
Dimensions W / H / D
Temperature range
Degree of protection

IEC
250 V AC
65 V DC
Depends on the selected item version
See trigger characteristic
Slow-blow
8.2 mm / 64 mm / 88.5 mm
-20 °C ... 60 °C
IP40 (Actuation area)

Ordering data
Description

Nominal current

Thermal miniature circuit breaker, can be plugged into UK 6
FSI/C or ST 4-FSI/C fuse terminal block
0.25 A
0.5 A
1A
2A
3A
4A
6A
8A
10 A

Type

Order No.

Pcs. /
Pkt.

TCP 0,25A
TCP 0,5A
TCP 1A
TCP 2A
TCP 3A
TCP 4A
TCP 6A
TCP 8A
TCP 10A

0712123
0712152
0712194
0712217
0712233
0712259
0712275
0712291
0712314

20
20
20
20
20
20
20
20
20

UK 6-FSI/C

3118203

50

ST 4-FSI/C

3036372

50

Accessories
Fuse terminal block, for mounting on NS 32... or NS 35...

Fuse terminal block, with spring-cage connection, for mounting
on NS 35...

Response [s]

Lateral groove labeling

10

4

10

10

For ZB 5, see page 111

0,25 - 4 A
6 - 10 A

3

2

10

1

0,1
0,8 1

2

4

6

8 10

20

30

Multiples of IN

Trigger characteristic

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

265

Protective devices
Device circuit breakers
TMC thermomagnetic circuit breaker

– Available with fast-blow and mediumblow characteristic curve for various
nominal current strengths
– Single or two-pos. main current path
– All TMCP ... plug-in thermomagnetic circuit breakers also have integrated signal
contacts
Notes:
For additional technical data, drawings, and accessories, please
visit www.phoenixcontact.net/products.
1)

Please observe the type key on the right side.

2)

Main contact

DIN-rail mountable

Can be plugged onto base





Total width 12.5 mm

Total width 12.5 mm

Technical data
Rated data
Rated voltage
Rated voltage
Rated current In
Disconnection
Switch-off time
Fuse type
Rated short-circuit switching capacity Icn
General data
Dimensions W / H / D
Connection method
Connection data solid / stranded / AWG
Stranded conductor cross section with ferrule
Temperature range
Degree of protection

Technical data

IEC
250 V AC
65 V DC
Depends on the selected item version

IEC
250 V AC
65 V DC
Depends on the selected item version

See trigger characteristic
Fast blow (F1)
400 A / 2500 A (32 V DC)

See trigger characteristic
Fast blow (F1)
400 A / 2500 A (32 V DC)

12.5 mm / 82.5 mm / 96 mm
Screw connection
0.2 ... 6 mm²2) / 0.2 ... 4 mm² / 24 - 10
0.25 ... 4 mm²
-30 °C ... 60 °C
IP30 (Actuation area) / IP20 (Connection area)

38 mm / 115 mm / 121 mm
plug-in
-30 °C ... 60 °C
IP30 (Actuation area) / IP00 (Connection area)

Ordering data
Description

Nominal
current

Ordering data

Type

Order No.

TMC 1 F1 100 0,2A

0914015

Pcs. /
Pkt.

Type

Order No.

Pcs. /
Pkt.

Thermomagnetic circuit breaker, with universal foot for
mounting on NS 32... or NS 35...1)
6

Thermomagnetic circuit breaker, plug-in, one,
two or three-position1)
TMCP 1 F1 300 0,2A

0915506

6

SPRING-LOCK

0713009

10

TMCP SOCKET M

0916589

10

TMCP CONNECT LR

0916592

3

TMCP SB

0916602

6

Accessories

Accessories

Spring lock, for mechanical locking in the case of overhead
mounting, 1-pos.
Modular socket, 2-position, for holding two circuit breakers,
each with a single position
Socket termination elements, can be plugged in both left and
right, contain the connections for the reset inputs/group query

Signal bridge, plug-in, for bridging group signaling when
there is a free slot on the TMCP SOCKET M socket

266

PHOENIX CONTACT

Protective devices
Device circuit breakers
Drilling diagram for front plate
mounting of TMCP

Note:
When mounted in rows with simultaneous load, a mutual thermal effect occurs. This is equivalent to a rise in the ambient temperature.
It depends on the nominal current, the ambient temperature, the
number of devices, and the distance between devices. The nominal
device current can be either overdimensioned (see multiplication
factor for temperature behavior) or limited to just > 80%. Please request the maximum permissible current if planning to mount in rows.

32
16

30

2)
12,5

Multiplication factor for higher ambient temperatures for TCP..., UT 6TMC..., TMC..., and TMCP...

4

1)

Ambient temperature, °C

S

1,5

11,5

Multiplication factor

-30
-20
-10
0
+10
+23
+30
+40
+50
+60

0.76
0.79
0.83
0.93
0.93
1.00
1.04
1.11
1.19
1.29

90°
S > 1,5 mm
1)

1-pos.

²) 2-pos.

TMC and TMCP trigger characteristics
Medium-blow (M1): 0.2 - 6 A nominal value

Medium-blow (M1): 8 - 16 A nominal value

Lower tripping limit: 1.05 IN
Upper tripping limit: 1.4 IN

Lower tripping limit: 1.05 IN
Upper tripping limit: 1.4 IN

10000

10000
-30°C

-30°C

1000

1000

1000

+23°C
100

10

1
DC

AC

0,01

1

2

3 4

6 8 10

Switching time in seconds [s]

+50°C

0,1

+23°C

+23°C

1

0,1

The type key indicates the unique structure of the product.

DC

AC

0,01

Multiples of IN

TMC and TMCP type keys

+55°C

10

0,001

20 30 40 60 100

100
Switching time in seconds [s]

100
Switching time in seconds [s]

Lower tripping limit: 1.05 IN
Upper tripping limit: 1.4 IN

10000
-30°C

0,001

Fast-blow (F1): 0.2 - 16 A nominal value
Only for DC applications

1

2

3 4

6 8 10

20 30 40 60 100

+55°C

10

1

0,1

0,01

0,001

Multiples of IN

1

2

3 4

6 8 10

Type

Main current paths

Characteristic curve

Auxiliary contact versions

Nominal current

TMC
or TMCP

1 = Single-pos.
2 = Two-pos.
3 = Three-pos.

F1 = Therm. 1.05 - 1.4 IN,
magn. 2 - 4 IN DC (fast-blow),
Only for DC applications
M1= Therm. 1.05 - 1.4 IN,
magn. 6 - 12 IN AC,
7.8 - 15.6 IN DC
(medium-blow)

100 = Single-pos.: 1 N/O contact
200 = Single-pos.: 1 N/C contact
120 = Two-pos.: 1 N/O contact,
1 N/C contact
122 = Three-pos.: 1 N/O contact,
2 N/C contacts

0.2 A
0.3 A
0.4 A
0.5 A
0.6 A
0.8 A
1A
1.5 A
2A

3004) = 1 N/O contact and 1 N/C
contact per position

Ordering example:

20 30 40 60 100

Multiples of IN

2.5 A
3A
4A
5A
6A
8A
10 A
12 A
16 A

TMC with single-pos. main current path, one N/O contact, medium-blow characteristic curve, and a nominal current of 2 A.

TMC
4)

1

M1

100

2A

Only version for TMCP, cannot be used for TMC.

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

267

Protective devices
Device circuit breakers
EC-E1 and EC-E4 electronic circuit
breakers
Line+

1

Line+

14

12

13

11

2

2

LOAD+

1

LOAD+

With signal contact as N/C contact or N/O contact
0V

3

EC-E 1 ...

0V

3

EC-E 4 ...


Total width 12.5 mm

Technical data

– Selective protection of all 24 V DC load
circuits at switched-mode power supply
units
– A combination of active electronic current limitation in the event of short circuit and overload shutdown ensures that
the circuit breaker can respond to overloads faster than the switched-mode
power supply unit
– The residual current is always limited to
1.3 - 1.8 times the nominal current
A complete data sheet is available to
download for each product at
www.phoenixcontact.net/products.

Rated data
Operating voltage
Rated current In
Disconnection
Switch-off time
Fuse type
General data
Dimensions W / H / D
Connection method
Connection data solid / stranded / AWG
Stranded conductor cross section with ferrule
Temperature range
Degree of protection
Inflammability class according to UL 94

IEC
24 V DC
Depends on the selected item version
See trigger characteristic
Electronic
12.5 mm / 83 mm / 80 mm
Screw connection
0.5 ... 16 mm² / 0.5 ... 16 mm² / 20 - 6
0.5 ... 10 mm²
0 °C ... 50 °C (without condensation)
IP20 (Housing)
V0

Ordering data
Description

Nominal current

Pcs. /
Pkt.

Type

Order No.

0.5 A
1A
2A
3A
4A
6A
8A
10 A
12 A

EC-E1 0,5A
EC-E1 1A
EC-E1 2A
EC-E1 3A
EC-E1 4A
EC-E1 6A
EC-E1 8A
EC-E1 10A
EC-E1 12A

0903022
0903023
0903024
0903025
0903026
0903028
0903029
0903030
0903031

6
6
6
6
6
6
6
6
6

0.5 A
1A
2A
3A
4A
6A
8A
10 A
12 A

EC-E4 0,5A
EC-E4 1A
EC-E4 2A
EC-E4 3A
EC-E4 4A
EC-E4 6A
EC-E4 8A
EC-E4 10A
EC-E4 12A

0903040
0903032
0903033
0903034
0903035
0903036
0903037
0903038
0903039

6
6
6
6
6
6
6
6
6

2966692
2966786
0901028
1205053

20
20
10
10

Electronic circuit breaker, signal contact: 1 N/O contact

Notes:
For additional technical data, drawings, and accessories, please
visit www.phoenixcontact.net/products.

Electronic circuit breaker, signal contact: 1 N/C contact

Accessories
Cont. plug-in bridge, 500 mm long, isolated, can be cut to length,
for potential distribution
Stop point
typ. 1,1 x l N
Switching time [s]

10
10

2

10
5
1
0,1
0,01
0

1

2

IK

3

Multiples of IN

Trigger characteristic

268

Lateral groove labeling

For ZBF 12, see page 111

4

3

10

Screwdriver

FBST 500-PLC BU
FBST 500-PLC RD
FBST 500 TMC-N GY
SZS 0,6X3,5

Nominal current: 32 A

1,8 x l N

PHOENIX CONTACT

Protective devices
Device circuit breakers
EC-E electronic circuit breakers

Line+

1

Status 23
Reset 22

2

LOAD+

With reset input and status output
0V

3

EC-E ...


Total width 12.5 mm

Technical data

– Selective protection of all 24 V DC load
circuits at switched-mode power supply
units
– A combination of active electronic current limitation in the event of short circuit and overload shutdown ensures that
the circuit breaker can respond to overloads faster than the switched-mode
power supply unit
– The residual current is always limited to
1.3 - 1.8 times the nominal current
A complete data sheet is available to
download for each product at
www.phoenixcontact.net/products.

Rated data
Operating voltage
Rated current In
Disconnection
Switch-off time
Fuse type
General data
Dimensions W / H / D
Connection method
Connection data solid / stranded / AWG
Stranded conductor cross section with ferrule
Temperature range
Degree of protection
Inflammability class according to UL 94

IEC
24 V DC
Depends on the selected item version
See trigger characteristic
Electronic
12.5 mm / 83 mm / 80 mm
Screw connection
0.5 ... 16 mm² / 0.5 ... 16 mm² / 26 - 6
0.5 ... 10 mm²
0 °C ... 50 °C (without condensation)
IP20 (Housing)
V0

Ordering data
Description

Nominal current

Pcs. /
Pkt.

Type

Order No.

EC-E 0,5A DC24V
EC-E 1A DC24V
EC-E 2A DC24V
EC-E 3A DC24V
EC-E 4A DC24V
EC-E 6A DC24V
EC-E 8A DC24V
EC-E 10A DC24V
EC-E 12A DC24V

0903041
0903042
0903043
0903044
0903045
0903046
0903047
0903048
0903049

6
6
6
6
6
6
6
6
6

2966692
2966786
0901028

20
20
10

Electronic circuit breaker, with reset input
0.5 A
1A
2A
3A
4A
6A
8A
10 A
12 A

Notes:
For additional technical data, drawings, and accessories, please
visit www.phoenixcontact.net/products.

Accessories
Cont. plug-in bridge, 500 mm long, isolated, can be cut to length,
for potential distribution

Switching time [s]

Stop point
typ. 1,1 x l N
10
10

Nominal current: 32 A

FBST 500-PLC BU
FBST 500-PLC RD
FBST 500 TMC-N GY

Lateral groove labeling

For ZBF 12, see page 111

1,8 x l N

4

3

10

2

10
5
1
0,1
0,01
0

1

2

IK

3

Multiples of IN

Trigger characteristic

For additional information, visit www.phoenixcontact.net/products

PHOENIX CONTACT

269

Protective devices
Device circuit breakers
ECP-E plug-in electronic circuit
breaker

GND (-)

13

Reset

14

Reset

12

Status

2

LOAD (L+)

With reset input and status output


Total width 12.5 mm

Technical data
Rated data
Operating voltage
Rated current In
Disconnection
Switch-off time
Fuse type
General data
Dimensions W / H / D
Temperature range
Degree of protection
Inflammability class according to UL 94

For additional technical data, drawings, and accessories, please
visit www.phoenixcontact.net/products.

See trigger characteristic
Electronic
38 mm / 115 mm / 112.5 mm
0 °C ... 50 °C (without condensation)
IP30 (Actuation area)
V0

Ordering data
Description

Nominal current

Pcs. /
Pkt.

Type

Order No.

ECP-E 1A
ECP-E 2A
ECP-E 3A
ECP-E 4A
ECP-E 6A
ECP-E 8A
ECP-E 10A
ECP-E-12A

0900113
0900210
0900317
0900414
0900618
0900812
0901002
0900126

5
5
5
5
5
5
5
5

TMCP SOCKET M

0916589

10

TMCP CONNECT LR

0916592

3

Electronic circuit breaker, standard variant with status output
and reset input, can be plugged into TMCP socket, signaling
through three-color LED
1A
2A
3A
4A
6A
8A
10 A
12 A

Accessories

Socket termination elements, can be plugged in both left and
right, contain the connections for the reset inputs/group query

Lateral groove labeling

Stop point
typ. 1,1 x l N
10

Switching time [s]

IEC
24 V DC
Depends on the selected item version

Modular socket, 2-position, for holding two circuit breakers, each
with a single position

Notes:

10

1,8 x l N

4

3

10

2

10
5
1
0,1
0,01
0

1

2

IK

3

Multiples of IN

270

On/Off

Control Unit

LINE (+)

11

After detecting overload or short-circuit
in the load circuit, the load output of the
ECP-E is locked. The current flow is interrupted in the faulty current circuit. The
ECP-E and subsequently the current circuit
can be activated again through the electronic reset input (13;14) or manually at the device through the slide-type switch.
The ECP-E has the following features:
– The operating or error state is indicated
by a multi-color LED as well as an integrated status output (12)
– Design width of just 12.5 mm
– Can be plugged onto TMCP SOCKET M
base
A complete data sheet is available to
download for each product at
www.phoenixcontact.net/products.

1

The area of application for the electronic
circuit-breaker ECP-E extends to all aspects
connected with the power supply unit. In
the event of an overload, power supply units
reduce their output voltage and all the connected loads are no longer supplied with
sufficient power, e.g., in the case of shortcircuit at the load.
The solution here is the electronic circuit
breaker:
– Selective protection of all 24 V DC load
circuits at switched-mode power supply
units
– Residual current always limited to
1.8 times the nominal current
– Capacitive loads can be switched on and
loads are only switched off in the event of
an overload or short circuit

PHOENIX CONTACT

ZB 6, see page 111

Protective devices
Device circuit breakers
ECP-E2 plug-in electronic circuit
breaker

LINE (+)

11 13

GND (-)

14

SO

SC

12

Control

2

LOAD (+)

 12 V DC, the possible short-circuit
current of the source must not exceed
100 mA. Otherwise a fuse that enables
shutdown within 5 seconds should be
selected. Self-quenching capability is
ensured for voltages ≤ 12 V. Please note,
however, that the specific technical data
for the product must always be observed.
Backup fuse: the system must be
protected against impermissibly high
short-circuit currents due to arrester
overload. The maximum permissible or
required backup fuse for the affected
arrester is documented in the technical
data of the relevant product.

The main function-specific
components for lightning arresters and
surge protective devices are spark gaps,
gas-filled surge arresters, varistors, and
diodes, as well as decoupling impedances.
All components have specific
advantages and disadvantages. In order to
achieve optimum protection, protective
circuits and multi-stage protection
concepts that combine various
components can be implemented.

Suppressor diode

The reverse voltage UR is the highest
voltage that the diode can safely block.
A current of 1 mA flows through the
suppressor diode at the breakdown
voltage UB. At this point the suppressor
diode starts limiting the surge voltage.
The maximum clamping voltage UC is
the highest voltage which can be present
at the suppressor diode in the event of a
peak pulse current Ipp (10/1000) μs.

3

1

OUT

IN
2

Electronics

4

Correct

3

1

Electronics

OUT

IN
4

2

Incorrect
Ground connection

276

PHOENIX CONTACT

U/I characteristic curve of a suppressor diode
Explanation:
UR
= Reverse voltage
UB
= Breakdown voltage
UC
= Clamping voltage
Ipp
= Peak pulse current
IR
= Reverse current

Technical information
General installation notes/surge voltage limiting components
Varistors

Gas-filled surge arresters

Block varistor with thermal disconnect device

Varistors are “voltage-dependent
resistors” which, due to their voltage/
current characteristic curves enable a high
discharge capacity with a low residual
voltage.

Disc varistor

Gas-filled surge arresters consist of an
electrode arrangement in a ceramic or
glass tube. Between the electrodes is an
inert gas, such as argon or neon. When
the igniting voltage is reached, the
component changes to a low-resistance
state as a result of the gas discharge used.
The igniting voltage is not a constant,
instead it is dependent on the rate of rise
of the surge voltage.
After igniting the discharge path, an arc
voltage between 10 and 30 V typically
occurs, which can be measured as a
voltage drop at the arrester. In this
low-resistance state, a line follow current,
whose value depends on the impedance of
the mains connected upstream, can flow
through the arrester. In order to interrupt
line follow currents that exceed the
self-quenching capability, a fuse must be
connected upstream of the surge arrester.
Series connection of varistors or resistors
is also possible.

The ArC spark gap in the FLASHTRAB
lightning arrester is based on arc chopping
technology. Two spark horns positioned
opposite one another are kept at a
distance by an isolator bridge bar. In
addition, a baffle plate is fitted below the
electrodes in the direction of the opening.
In the event of a surge voltage, surface
discharge occurs along the isolator bridge
bar, which creates an arc. This is driven
along the spark horns towards the baffle
plate where it is chopped up. The resulting
physical effects quench the arc and the
associated line follow currents.
A significant increase in the follow current
quenching capacity can be achieved with
spark gap types in which quenching plates
are arranged around the spark horns.

Encapsulated ArC spark gap
V
U

A

B

UN

10

-5

10

-3

10

0

10

3

A

10

5

I

U/I characteristic curve of metal oxide varistors
Explanation:
A
= High-resistance operating area
B
= Low-resistance operating area/
limiting area

Spark gaps
ArC spark gap with quenching plates

1200
V
VS/UZ

10 kV/ms
1 kV/ms

800
600

100 V/s

100 V/ms

400
200
0

10

2

104

106

108

V/s 1010
du/dt
dv/dt

Characteristic ignition curve of a gas-filled surge arrester
Static response behavior
Dynamic response behavior

Characteristic ignition curve of a spark gap
ArC spark gap

PHOENIX CONTACT

277

Technical information
Explanation of terms

Surge protective devices

Explanation of terms

The wide range of different
applications also requires numerous
different surge protective devices with
application-specific properties. Important
criteria include the type of circuit, the
surge-voltage limiting properties, and the
design. The TRABTECH range from
Phoenix Contact offers numerous
versions, such as adapters, junction boxes
or DIN-rail-mountable arresters in a
modular and compact design, providing
practical system solutions for all
applications.
In line with their intended application,
surge protective devices are designed for
high electrical loads. However, excessive
or very frequent surge voltages may lead
to overload. This can result in a reduction
or even failure of the protective function,
and the affected protective device having
to be replaced. Where possible, surge
protective devices should therefore have a
plug-in design and support testing.
The TRABTECH product range from
Phoenix Contact takes these
requirements into consideration as far as
modern technology permits. The product
range includes surge protective devices in
the form of adapters, as well as devices
with a two-piece plug-in modular design.
The protective devices in the
FLASHTRAB, VALVETRAB, PLUGTRAB,
and COMTRAB product ranges are
particularly interesting with regard to their
plug-in capability and testability. They have
been developed with various protective
circuits and different nominal voltages for
applications in power supply,
measurement and control, and data
interface protection.
With components that are perfectly
designed to work together, i.e., gas-filled
surge arresters, varistors, and suppressor
diodes depending on the protective
circuit, their specific advantages are fully
utilized.

AC withstand voltage
The r.m.s. value of the highest
sinusoidal voltage at mains frequency
which will not lead to a disruptive
discharge under the specified test
conditions.

Asymmetrical voltage, common
mode voltage
Average voltage between each
conductor and a specified reference
point, usually reference ground or
ground.

Aging
Modification of the original
performance data due to disturbing
pulses, operation or unfavorable ambient
conditions.

Burst
Pulses which occur repeatedly within
a specific time interval.

Ambient conditions
The immediate ambient conditions
for the device or the relevant air and
creepage distances.
Arc voltage U
The arc voltage is the instantaneous
value of the voltage on a discharge path
(arc discharge) during an arresting
process.
bo

Arrester
Item of equipment that mainly
consists of voltage-dependent resistors
and/or spark gaps. Both elements can be
connected in series or in parallel, or even
used individually. Arresters are used to
protect other electrical equipment and
electrical systems against impermissibly
high surge voltages.
Associated electrical equipment
An item of electrical equipment in
which not all circuits are intrinsically safe,
but which contains circuits that can
influence the safety of the intrinsically
safe circuits to which they are connected.
Asymmetrical interference
Asymmetrical means that the source
of interference and the potentially
susceptible equipment are grounded, i.e.,
they have a capacitive or galvanic
connection to the protective conductor.
As shown in the figure, the interference
moves from the source along both
conductors to the potentially susceptible
equipment and back via ground. The
terms “common-mode interference” or
“common mode” are also used.

Source of
interference

Potentially
susceptible
equipment

Common mode voltage
The common mode voltage is the
voltage which occurs in the event of
interference between live conductors and
ground.
Coupling
Interaction between circuits, in which
energy is transferred capacitively,
inductively or galvanically from one
circuit to the other.
Direct or close-up strikes
These cause surge voltages with an
energy level that constitutes a
considerable part of the total energy of
the lightning discharge.
Discharge of static electricity;
electrostatic discharge; ESD
The transmission of an electrical
charge between bodies with different
electrostatic potentials when they are in
close proximity or touching.
Disconnect device
This is a device which disconnects a
SPD from the mains when it fails. It is
designed to prevent a permanent fault in
the system caused by the faulty surge
arrester and provide an optical indication
of the faulty SPD.
Disturbance variable
The disturbance variable is an
electromagnetic (or electrical or
magnetic) variable, which can have an
undesirable influence on electrical
equipment.
Electromagnetic compatibility
(EMC)
The ability of a device or system to
operate without faults in an
electromagnetic environment without
itself causing electromagnetic
interference, which would be
unacceptable for other devices in this
environment.
Electromagnetic environment
The sum of all electromagnetic
phenomena at a given location.

278

PHOENIX CONTACT

Technical information
Explanation of terms

Electromagnetic interference
A loss in the quality of the operating
behavior, such as malfunction or failure of
electrical or electronic equipment, that is
caused by an electromagnetic disturbance
variable.
Equipment to be protected
All equipment of a structural system
or a range which requires surge
protection or lightning protection.
Equipotential bonding
The removal of potential differences
between conductive parts, in which all
points assume virtually the same
potential.
A distinction is made between
functional equipotential bonding and
protective equipotential bonding.
Equipotential bonding conductors
These are electrically conductive
connections used to create equipotential
bonding.
Equipotential bonding strip
This is the strip which is designed to
connect protective conductors,
equipotential bonding conductors, and
conductors for functional earth
grounding to the ground conductor and
the ground electrodes.
Equipotential bonding system
This refers to all the interconnected
equipotential bonding conductors,
including the conductive parts such as
housing or external conductive parts
which work in the same way.
The equipotential bonding system can
also be the grounding system or part of a
grounding system.
Exposure
Exposure is an insufficient distance
between the lightning protection system
and metal installations or electrical
systems which leads to a risk of flashover
or disruptive discharge in the event of a
lightning strike.
Exposure voltage
The exposure voltage is a voltage that
occurs at the exposure point when
lightning strikes the lightning protection
system.
Follow current I
Current which flows through the SPD
following discharge and is supplied by the
mains. The follow current differs
considerably from the continuous
operating current.
f

Gas-filled surge arrester
The gas-filled surge arrester is a
discharge path which is filled with a gas
other than air, generally an inert gas.
Ground
This expression refers to the earth
and the ground.
Ground conductor
A conductor which connects the
equipment to be grounded to a ground
electrode, as long as the ground
conductor is not laid in the ground or, if
laid in the ground, is insulated.
Ground electrode
A conductor embedded in the ground
with an electrically conductive
connection to ground. Parts of supply
lines to a ground electrode, which are not
insulated in the ground, are considered to
be parts of the ground electrode.
Grounding
Grounding is the sum of all means and
measures used for grounding.

Insertion attenuation
To determine the insertion
attenuation of a SPD, the mains and
frequency are specified. The attenuation
value is defined as the ratio of voltages
that occur immediately before and after
the insertion point of the SPD to be
tested. The result is expressed in
decibels.
Insulation coordination
The assignment of characteristic
insulation data for an item of equipment
for:
– Expected surge voltages
– Characteristic data of the surge
protective device
– Expected ambient conditions
– Protective measures against
contamination
Interference suppression
Measure to reduce or avoid the
electromagnetic disturbance variables
that occur.

Grounding resistance
The resistance between the
grounding system and the reference
ground. The amount of grounding
resistance depends on the interaction of
the individual ground electrodes.

Intrinsically safe circuit
A circuit protected against sparks and
thermal effects that may occur under the
conditions specified in DIN EN 60079-11
(which include error-free operation and
specific fault conditions), which can cause
the ignition of a particular explosive gas
atmosphere.

Impulse sparkover voltage of
1.2/50 s
Highest voltage value before the
disruptive discharge between the
electrodes of the spark gap of a SPD.

Intrinsically safe electrical
equipment
Electrical equipment in which all
circuits are intrinsically safe.

Impulse withstand voltage U
The peak value of the highest surge
voltage with a predefined form and
polarity, which will not lead to a
disruptive discharge under the specified
test conditions.
Note: the impulse withstand voltage
is equal to or greater than the rated surge
voltage.
st

Inactive parts
Inactive parts are conductive parts
that are electrically isolated from all live
parts through basic insulation.

Lightning protection system
All devices as a whole that provide
external and internal lightning protection
for the system to be protected.
Lightning surge current I
Lightning surge currents are
characterized by the parameters peak
value, charge, specific energy, and current
increase rate. The lightning surge current
Iimp is a measurement for the discharge
capacity of lightning arresters (class I). It
is determined according to a defined test
procedure using 10/350 μs waveform test
pulses.
imp

Lightning surge voltage
Surge voltage as a result of lightning
discharge.

PHOENIX CONTACT

279

Technical information
Explanation of terms
Lightning test current
The (10/350) μs lightning test current
has a rise time of 10 μs and a decay time
to half-value of 350 μs.

Potentially susceptible equipment
All electrical equipment whose
function can be influenced by disturbance
variables is referred to as potentially
susceptible equipment. Influence on
function may be in the form of a
functional disturbance, reduction in
function, malfunction or failure.

100

I
( %)
60

30

0

10

350
t ( us)

Protection level U
A parameter that characterizes the
performance capabilities of the SPD with
regard to voltage limitation via its
connection terminal blocks. This value,
which should be specified by the
manufacturer, must be greater than the
highest measured value of the clamping
voltages.
p

10/350 lightning current pulse according to IEC 62305-1

Live parts
Live parts are conductors and
conductive parts of equipment that are
energized under normal operating
conditions.
Maximum continuous voltage U
The rated voltage is the maximum
permissible r.m.s. value of the
power-frequency AC voltage, which may
be permanently applied to the protective
paths of the arrester.
C

Nominal current IN or load current IL
Highest continuous current for
products according to IEC 61643 which
can flow through the surge protective
device at the specified temperature
without altering the electrical operating
properties. For higher operating
temperatures, the nominal current is
lower (derating).
Nominal discharge surge current I
Peak value of the current flowing
through the SPD with surge form
(8/20) μs. It is used to classify the SPD
according to class II. Source:
EN 61643-11

n

Protective paths
The voltage-limiting or switching
components of the SPD can be
connected between conductor/
conductor, conductor/ground,
conductor/neutral conductor, and neutral
conductor/ground or a combination of
these options. These circuit types are
referred to as protective paths.
Pulse
Rapid, brief alteration of a physical
variable, followed by a fast return to the
original value.
Pulse burst; burst
Result of a limited number of pulses
or waves of a limited duration.
Rate of rise
Average rate of change of a variable
between two specified values, e.g., 10%
and 90% of the peak value.
Reference ground
An area of the earth, particularly of
the earth's surface, which is so far away
from the ground conductors that no
noticeable voltages occur between any
points of this area as a result of the
current entering the earth.

100
I

Normal mode voltage
The normal mode voltage is the
voltage which occurs in the event of
interference between two conductors of
a circuit.

90

( %)

50

10
0
8
20

t ( us)

8/20 surge current pulse according to IEC 60060-1

Nominal voltage UN
A suitable rounded voltage value,
which is specified by the manufacturer for
equipment for the purpose of designation
or identification.

280

PHOENIX CONTACT

Remote strikes
These usually cause surge voltages
with a significantly lower energy level
than close-up strikes. Remote strikes are
responsible for causing surge voltages in
electrical and electronic systems.

Residual current device (RCD)
Residual current devices are devices
which isolate electrical systems from the
power supply system as soon as the
residual current to ground exceeds a
specific value.
Residual voltage U
The peak voltage value that occurs
while discharge surge current is flowing
via the terminal blocks of the SPD.
Source: EN 61643-11:2002
res

Response
A response is when either:
– The peak value of the ohmic
components of the current flowing
through the arrester reaches 5 mA
– A voltage dip with an increase in the
peak value of the current flowing
through the arrester to 5 mA occurs
Selective residual current device
Selective residual current devices are
time-delayed circuit breakers.
Short circuit stability
Highest interference-free
short-circuit current the SPD can
withstand.
Source of interference
A source of interference is the origin
of disturbance variables. In principle, any
electrical equipment, such as motors or
fluorescent lamps, can be a source of
interference.
Specialist
A specialist is a person who, because
of their education, experience, and
instruction, and their knowledge of
relevant regulations, can assess any
required operations and recognize any
possible dangers.
Note: when considering a person's
professional training, several years'
experience in the relevant field can also
be taken into account.
Spike
A relatively short single-polarity
pulse.
Surface discharge surge arrester
The surface discharge surge arrester,
according to DIN VDE 0845 Part 1, is a
discharge path in which gas discharge is
initiated by means of surface discharge.
Surge current of (8/20) μs
Surge current with a rise time of 8 μs
and a decay time to half-value of 20 μs.
Source: IEC 60060-1

Technical information
Explanation of terms
Surge current of (10/350) μs
Surge current with a rise time of 10 μs
and a decay time to half-value of 350 μs.
Source: IEC 62305-1
Surge protection equipment (SPE)
Surge protection equipment consists
of surge protective devices and all
equipment in telecommunications
systems, including their cables, used for
surge protection.

Surge voltage of (1.2/50) μs
Surge voltage with a rise time of
1.2 μs and a decay time to half-value of
50 μs. Source: IEC 60060-1
100
U

Symmetrical voltage, differential
mode voltage
Voltage between two live conductors
from one defined group.

90

( %)

50

30

Surge protective device (SPD)
A device to limit surge voltages and
discharge surge currents. It contains at
least one non-linear voltage-limiting
component.
Surge voltage
Any voltage with a peak value that
exceeds the corresponding peak value of
the maximum continuous voltage under
normal operating conditions.
Source: EN 60664-1

Symmetrical interference voltage
Interference voltage between
two wires of a cable (e.g., double cable)
or between two connection points of
electrical equipment for this cable type.

0

1,2
50
t ( us)

1.2/50 surge voltage pulse according to IEC 60060-1

100
90
U

Temperature range
Range between the minimum and
maximum temperature that may be
present at/in housing. For devices
without self-heating, this value is the
permissible ambient temperature. For
devices with self-heating, these values are
the maximum temperatures that may
occur at/in the device during operation.

( %)

To ground
An electrically conductive part, e.g.,
the lightning protection system is
connected to ground via a grounding
system.

50

30

Surge voltage category
Assignment of electrical equipment to
the anticipated surge voltage.

0
10
700
t ( us)

10/700 surge voltage pulse according to ITU-T K.44

100
90
I

Transient
Describes a phenomenon or variable
which changes during what is, in
comparison to the time scale being
observed, a short period of time between
two consecutive stationary states.

( %)

Transients
Irregular and relatively short positive
and/or negative voltage or current
changes between two stationary states.

50

10
0
10
1000

t ( us)

10/1000 surge current pulse according to IEEE C62.41.1

Switching surge voltage
Surge voltage as a result of a switching
operation.

Varistors
A varistor is a bipolar non-linear
resistor with a symmetrical voltage/
current characteristic curve and a
resistance value which decreases as the
voltage increases.

Symmetrical interference
As shown in the figure, the
disturbance variable moves from the
source along one conductor to the
potentially susceptible equipment and
back along the other conductor. The
terms “normal-mode interference” or
“differential mode” are also used.

Source of
interference

Potentially
susceptible
equipment

PHOENIX CONTACT

281

Technical information
Quality in quantity

Integrated management system
The aim of the Phoenix Contact
integrated management system is to
coordinate all the requirements regarding
products, processes, and organization.
Statutory and regulatory requirements, as
well as those of international standards and
our customers, are met and, in some cases,
even exceeded in all phases of the product
lifecycle.
In the Phoenix Contact management
system, the integration of quality,
environmental protection, and safety in the
workplace is monitored each year for
conformance by internationally recognized
independent bodies. Certification in
accordance with international standards ISO
9001, ISO 14001, and BS OHSAS 18001 is the
result of our corporate philosophy of meeting
the needs of our customers, staff, and
environment as best as possible. They serve as
the basis for innovative products with the
familiar high Phoenix quality standard, actively
practiced environmental protection, and
responsibility in the field of occupational
health and safety. Of course, we integrate all
further requirements of standards,
international approvals or special customer
requirements into company processes.
This system provides a building block for
the success of the Phoenix Contact Group
and its products and services.
CE marking
The CE mark was introduced as an
important instrument for the free movement
of goods and services within the single
European market. By attaching the mark to a
product, the manufacturer confirms that it
complies with all applicable European Union
(EU) directives. EC directives describe the
product properties with regard to device
safety and avoiding danger. These are legally
binding regulations of the European Union
(EU). In other words, compliance with the
requirements is a statutory condition for
282

PHOENIX CONTACT

marketing the product within the EU.
Where applicable, the products that our
company currently manufactures fall within
the scope of the following directives:
– 2006/95/EC
Electrical equipment designed for use within
certain voltage limits (Low Voltage
Directive)
– 2004/108/EC
Electromagnetic compatibility
(EMC Directive)
– 2006/42/EC
Safety of machinery
(Machinery Directive)
– 94/9/EC
Equipment and protective systems intended
for use in potentially explosive areas
(ATEX Directive 100a)
– 1999/5/EC
Radio and telecommunications terminal
equipment (R&TTE)
The standards upon which the specified
directives are based, have been part of our
standard of development for a long time. This
guarantees conformance with European
directives. The numbers of the directives
indicate their version at the time of
publication. In the event of changes to
directives and/or standards, our products will
undergo conformity assessment again in good
time and a new declaration of conformity will
be issued promptly. The current declarations
for each product can also be found in our
Download Center.
The EMC Directive occupies a special
place among the European directives listed. It
defines electromagnetic compatibility as a
fundamental property of devices based on
mandatory guidelines. European Law
therefore acknowledges the electromagnetic
compatibility of devices and systems as an
important condition for error-free operation
of machinery and systems. Phoenix Contact is
one of the leading international companies in
surge protection, and therefore possesses
broad expertise in EMC. This expertise and
the experience gained over years of
developing and applying industrial interface
and communication technology have resulted
in our products having an extremely high
standard of quality with regard to
electromagnetic compatibility. It was with a
view to providing other companies with this
expertise that our associate company,
Phoenix Testlab, was founded. Phoenix
Testlab GmbH is an independent, accredited
service provider offering EMC testing that
conforms to European standards. At Phoenix
Testlab, devices are also tested with regard to
their electrical safety, mechanical influences,
and their behavior in relation to
environmental influences. Furthermore,

Phoenix Testlab is a “Notified Body” in
accordance with EMC Directive 2004/108/EC
and according to R&TTE Directive 1999/5/EC
for radio and telecommunications terminal
equipment. As a “Telecom Certification
Body” (TCB), Phoenix Testlab may also
approve these products for markets in the
USA, Canada, and Japan.
Standards and regulations
All relevant standards and regulations are
used as the basis for the development and
maintenance of our products.
International standards are subject to
continuous changes as a result of
harmonization and new developments. In line
with this process, the current version of all
standards that are relevant to our products is
documented in the product area on our
website at www.phoenixcontact.net/
products.
Online product information service on
the web
Phoenix Contact's product range is
growing constantly.
Due to our commitment to product
monitoring, all products are subject to
improvement.
The Internet is an ideal platform to quickly
communicate new product developments and
improvements to the market.
You can quickly access the relevant
Phoenix Contact website for your region via
www.phoenixcontact.com. Here, you will
always find the latest overview of products,
solutions, and services from Phoenix Contact.
This includes technical documents, such as
data sheets and user manuals, the latest driver
and demo software, plus a means of
contacting the appropriate contact person
directly.

Technical information
Shock protection
Touch proof
60

formed by an even envelope curve 30 mm in
radius must surround the live parts. This area
must be touch proof, i.e., the live parts of the
electrical device must not be within reach of
the VDE test finger in accordance with
IEC 60529/DIN VDE 0470-1 (test finger).
Back of hand safety is specified for the
“rest of the area” up to 100 mm around the
operating element. Back of hand safety
means that when a force of 50 N is applied to
a ball with a diameter of 50 mm, this does not
come into contact with the live parts of the
equipment. No special measures for shock

200

company. The manufacturer of the electrical
equipment can only issue a confirmation that
products have been produced in accordance
with the relevant electrotechnical DIN VDE
regulations stipulated in BGV A 2. The
installer must bear this in mind when selecting
the equipment to be used.
In the field of connection technology,
Phoenix Contact offers a wide range of
products that are touch proof or that can be
protected against contact using covers.
Depending on the conditions, all of this must
be taken into account when selecting the
individual types of terminal block and
accessories.

Back of hand safety
Example: pressure actuation
The accident prevention regulations
BGV A 2 issued by the German employer's
liability insurance association for precision
mechanics and electrical engineering apply to
the operators of electrical systems and are
aimed at the prevention of electrical accidents
by means of special safety requirements.
These regulations contain specifications
regarding the safety distances for work,
operation, and occasional handling in the
proximity of “live parts” in low-voltage
systems up to 1000 V ~ or 1500 V –.
– Work with live parts is only permitted once
they have been de-energized. Operational
activities are only permitted in the vicinity of
live parts if these parts are de-energized or
are protected against direct contact (§ 6).
The following safety measures are applicable
when working in close proximity to live
parts:
– Provision of the de-energized state for the
duration of the work
– Ensure shock protection is in place in the
form of covers or barriers during the work
– Assurance that proximity limits will not be
violated (§ 7)
The term “occasional handling” has been
introduced for the operation of elements such
as pushbuttons, rocker arms or rotary
buttons in the proximity of live parts.
In VDE 0105-1, this is covered by
“operation with partial protection against
direct contact”.
Detailed specifications for “occasional
handling” can be found in DIN VDE 0106-100.
This specifies to what degree live parts in the
proximity of operating elements are to be
protected against contact. The basis for this is
the definition of a “protection area for
occasional handling”; this is the area into
which the user must reach in order to handle
the machine.
The most important thing is that an area

protection are provided outside this area.
Note: systems and equipment that are
operated with SELV up to 25 V ~ or 60 V – are
considered to be protected against direct
contact.
According to § 5, Subsection 4 of the
BGV A 2 regulations, there is no need to test
the condition of the system prior to initial
startup if the company has confirmation from
the manufacturer or installer that the
electrical systems and equipment conform to

BGV A 2. The confirmation required relates
to systems and equipment that have been
installed and are ready for operation and can
only be issued by the installer or installation
PHOENIX CONTACT

283

Technical information
Quality features of insulating housing
Thermoplastics
The majority of our insulating housing is
made from thermoplastic materials. Roughly
speaking, these can be divided into amorphous
and semi-crystalline substances.
Thermoplastics are processed using the
efficient and environmentally-friendly injection
molding process. They have good recycling
properties and can be re-used. We use many
materials that are modified in different ways to
meet the demanding requirements that
electrical and electronic modules, devices, and
systems have to meet with regard to their
mechanical, thermal, and electrical properties.

of the components used or other restrictive
parameters.
At very low temperatures, this means that
any form of mechanical load on the plastic
components must be avoided (e.g., mounting
of products on/removal of products from the
DIN rail, actuation of terminal points, locking/
ejection of relays from bases, prizing out of
plug-in bridges, bending of cables and lines,
etc.), as there is always an associated risk of
damage. Unless otherwise indicated, it is
recommended that you carry out the
specified mounting/operational tasks in a
temperature range from -10°C to +40°C.

Behavior of plastics under the
influence of temperature (operating
temperatures, mechanical influences)
All plastics undergo a process referred to
as thermal aging when they are subjected to
heat over long periods. This process causes
changes in the mechanical and electrical
properties of the material. External influences,
e.g., radiation, additional mechanical, chemical
or electrical stresses, amplify this effect.
Special tests on samples can yield
characteristic data which provides a good
means of drawing comparisons between
different plastics. However, applying these
characteristics to an evaluation of molded
plastic parts is only possible to a limited
extent, and can only give the designer a rough
guide when it comes to selecting a plastic
material. This catalog uses the following
assessment criteria: the RTI value according
to UL746B/ANSI 746 B (elec. based on
dielectric strength) and the Ti value
according to IEC 60216-1 (based on a 50%
reduction in tensile strength after
20,000 hours).
IEC 60947-7-1/EN 60947-7-1 specifies a
permissible temperature increase of 45 K for
modular terminal blocks under nominal load.
Phoenix Contact terminal blocks meet this
requirement.
The properties of plastics are not only
affected by the influence of heat as described
above; they also undergo changes as a result of
cold influences. When subjected to cold as
well as low levels of humidity, plastics become
increasingly brittle with the result that they
are no longer capable of withstanding the
same mechanical loads. As the table on the
right shows, the plastics concerned can be
used down to a temperature of -40°C, but
only without a mechanical load. As far as the
products presented in the catalog are
concerned, it is the ambient temperature
specified in each case that is to be regarded as
definitive for operation. Regardless of the
plastics used, this may be subject to further
restrictions (e.g., limited to -20°C) as a result

Inflammability characteristics of
plastics (UL 94)
Inflammability tests for plastics have been
defined by Underwriters Laboratories (USA)
in regulation UL 94. This applies to all areas of
application, but in particular to electrical
engineering. A horizontal or vertical test is
carried out at the test laboratory to
determine the inflammability of the plastic
material with a naked flame. In order of
increasing resistance to combustion, the
evaluation classes are HB, V2, V1, V0, and 5V.
Test results are recorded on “yellow cards”
and are published annually in the Recognized
Component Directory.

284

PHOENIX CONTACT

Thermoplastics: non-reinforced
polyamide, PA
We use modern, semi-crystalline
polyamide insulation material, which has now
become an essential component in electrical
engineering and electronics. It has long
occupied a leading position and is authorized
for use by the relevant approval authorities
such as the CSA, NEMKO, KEMA, PTB, SEV,
UL, VDE, etc.
Polyamide also has excellent electrical,
mechanical, chemical, and other properties,
even at high operating temperatures. Brief
peak temperatures up to approximately
200°C are permitted as a result of heat aging
stabilization. Depending on the type (PA 4.6,
6.6, 6.10, etc.), its melting point is in the region
of 215°C to 295°C.
Polyamide absorbs moisture from its
surroundings, on average 2.8%. However, this
moisture is not in the form of crystallization
water in the plastic itself, but chemically
bonded H O groups in the molecule
structure. This makes the plastic flexible and
resistant to breakage, even at temperatures as
low as -40°C. According to UL 94, PA belongs
to inflammability class V2 to V0.
2

Thermoplastics: polyester, PBT
We use the semi-crystalline
thermoplastic polyester in non-reinforced
and fiberglass-reinforced variants for special
applications which require increased
dimensional and form stability.
In addition to the high operating
temperature, the material is characterized by
excellent mechanical strength and hardness,
and does not absorb moisture from its
surroundings. PBT is therefore particularly
suitable for strips, for example, which are
soldered onto PCBs and subsequently have to
pass a burn-in test while they are subjected to
heat. According to UL 94, PBT belongs to
inflammability class V2 to V0.
Thermoplastics: polycarbonate, PC
Polycarbonate combines many advantages
such as rigidity, impact strength, transparency,
dimensional stability, good insulation
properties, and resistance to heat.
This amorphous material only absorbs
moisture to a very limited degree, and is used
for items such as large, rigid electronic
component housing.
In its transparent form, polycarbonate is
particularly suitable for use as cover profiles
or marking materials.
PC has good resistance properties against
mineral acids, saturated aliphatic
hydrocarbons, gasoline, greases, and oils.
The material is less resistant to solvents,
benzene, lyes, acetone, and ammonia. Strain
cracks may result from contact with certain
chemicals.
According to UL 94, PC belongs to
inflammability class V2 to V0.

Technical information

Thermoplastics:
polycarbonate fiber-reinforced, PC-F
Compared to non-reinforced materials,
fiber-reinforced polycarbonates feature
greater rigidity, impact strength, and operating
temperature. In other respects, their
properties are largely identical to those of
non-reinforced polycarbonate.

According to UL 94, the molding
compound used belongs to inflammability
class HB to V0.

Dimensions: width / height / depth
The dimensions for “width / height /
depth” are defined as follows for all DIN-rail
mountable products in the INTERFACE
range:
– Width: measurement taken along the
DIN rail
– Height: measurement taken across the
DIN rail
– Depth: measurement taken starting from
the mounting plate and including the NS 35/
7,5 DIN rail (EN 60715)
The width, height, and depth never
change, even if the products shown in this
catalog happen to be photographed from
two different perspectives (horizontal or
vertical).
To make things easier for you, one of the
following two symbols has been included next
to each product photo:

Thermoplastics: ABS
We use the thermoplastic molding
compound ABS for products which must have
good impact and notched impact properties in
addition to high mechanical stability and
rigidity. The products are resistant to
chemicals and stress cracking due to their
special surface quality and hardness.
The characteristic thermal properties
provide good dimensional stability at both low
and high temperatures. Products made from
ABS can be coated with metallic surfaces, e.g.,
nickel.

H
D

Properties

Unit/level

Polyamide
PA

Polyester
PBT

Polycarbonate
PC

Polycarbonate
PC-F

°C

≤ 105

≤ 105

≤ 125

≤ 120

≤ 80

°C

-40

-40

-40

-40

-40

Dielectric strength acc. to IEC 60243-1/DIN VDE 0303-21

kV/cm

600

400

> 300

Creep resistance

CTI...M

550

225

175

IEC 60112/DIN VDE 0303-1

CTI...

600

225

175

Tropical and termite resistance

Good

Good

Good

Specific contact resistance
Ω cm
IEC 60093/VDE 0303 Part 30; IEC 60167/VDE 0303 Part 31

1012

1016

> 1016

Surface resistance
Ω
IEC 60093/VDE 0303 Part 30; IEC 60167/VDE 0303 Part 31

1010

1013

> 1014

Inflammability class according to UL 94

V2 - V0

V0

V2 - V0

RTI */**

* According to UL 746 B/ANSI 746 B (elec.)

W

W
H

ABS

Minimum temperature (without mechanical load)

Operating temperature

D

850
200
175

600

> 1014

1014

1013
V0

HB - V0

** Minimum value

Tightening torque of terminal block
screws
IEC 60947-1/EN 60947-1, modified,
Table 4 specifies tightening torques for screw
connections based on the screw size for
electrical and mechanical type tests.

Extract from IEC 60 947-1/EN 60 947-1, Table 4
The torque according to IEC and the recommended tightening torque
for Phoenix Contact terminal blocks are specified.

Thread

Head screw with slot
Torque
[Nm]

Recommended
tightening torque
[Nm]

M2.5 (M2.6)

0.4

0.4 - 0.5

M3

0.5

0.5 - 0.6

M3.5

0.8

0.8 - 1.0

M4

1.2

1.2 - 1.5

M5

2.0

3

M6

2.5

4

PHOENIX CONTACT

285

Technical information
Connection cross section
The rated cross sections of modular
terminal blocks must be specified by the
manufacturer in accordance with
IEC 60947-7-1. The rated cross section is the
maximum conductor cross section that can be
connected in single-, multi- or fine-strand
versions subject to specific thermal,
mechanical and electrical requirements.
The manufacturer must also specify the
rated connection capacity, i.e., the area of
the conductor that can be connected, as well
as the number of conductors that can be
connected simultaneously and the necessary
preparation of the conductor ends. The
conductors can be solid (single or
multi-strand) or stranded (fine-strand).

required. If ferrules are nevertheless used to
protect stranded conductors against splicing,
the connection capacity of the stranded
conductor is generally reduced by one level.

These values can be found in the
product-specific technical data.
The rated connection capacity of the
Phoenix Contact modular terminal blocks
usually exceeds standard requirements, which
specify that it must only be possible to
connect one conductor with one of the two
next smallest cross sections, excluding the
rated cross section (standardized for the cross
section range from 0.2 to 35 mm2).
In addition, conductors with a rated cross
section can usually be wired with ferrules with
plastic sleeve.
Phoenix Contact modular terminal blocks
are designed to allow copper conductors to
be connected to them untreated. “Special
treatment” or the use of ferrules – both
permitted according to IEC 60947-7-1 – is not

Structure and dimensions of connecting cables

Cross
section

Single-strand

Multi-strand

Diameter
max.
dimension

Number of
wires

Diameter
max.
dimension

Number of
wires
(minimum
number)

Diameter
max.
dimension

Number of
wires
(guide
value)

Gauge No.

[∅ mm]

[circ. mils]

0.2

0.5

1

–

–

–

–

24

0.51

404

0.21

–

–

0.5

0.9

1

1.1

7

1.1

16

20

0.81

1022

0.52

0.97

1111

0.56

0.75

1.0

1

1.2

7

1.3

24

18

1.02

1620

0.82

1.16

1600

0.82

1

1.2

1

1.4

7

1.5

32

(17)

1.15

2050

1.04
1.50

2580

1.32

1.85

4100

2.09

2.41

6500

3.32

2.95

10530

5.37

3.73

16625

[mm2]

Fine-strand

Solid
wires

AWG

[∅ mm]

[circ. mils]

Stranded
wires
[mm2]

–

–

–

–

–

–

–

16

1.29

2580

1.31

1.5

1.5

1

1.7

7

1.8

30

(15)

1.45

3260

1.65

–

–

–

–

–

–

–

14

1.63

4110

2.08

2.5

1.9

1

2.2

7

2.3

50

(13)

1.83

5180

2.63

–

–

–

–

–

–

–

12

2.05

6530

3.31

4

2.4

1

2.7

7

2.9

56

(11)

2.30

8230

4.17

[mm2]
–

–

–

–

–

–

–

–

10

2.59

10380

5.26

6

2.9

1

3.3

7

3.9

84

(9)

2.91

13100

6.63

–

–

–

–

–

–

–

8

3.26

16510

8.37

10

3.7

1

4.2

7

5.1

80

(7)

3.67

20800

10.56

4.15

20820

10.55

-

6

4.12

26240

13.30

4.67

26250

13.39

4.62

33100

16.77

5.24

33100

16.77

-

4

5.19

41740

21.15

5.90

41650

21.24

7.8

196

3

5.83

52600

26.67

6.61

52630

26.67

7

9.2

276

2

6.54

66360

33.62

7.42

66150

33.74

-

-

-

1

7.35

83690

42.41

8.33

83706

42.69

-

-

-

-

-

1

5.3

7

6.3

126

-

-

-

-

-

-

25

-

-

6.6

7

35

-

-

7.9

-

-

-

-

Current carrying capacity
Standard IEC 60947-7-1/EN 60947-7-1/
DIN VDE 0611-1 specifies the test currents
for the individual conductor cross sections
listed in the adjacent table. The corresponding
currents are listed with the connection data
for the individual terminal blocks. The type
tests for modular terminal blocks are based on
this data.

PHOENIX CONTACT

8.48

(5)

4.6

16

286

American Wire Gauge [AWG]

Test currents according to IEC 60947-7-1/EN 60947-7-1, Table 5

Rated cross
section

[mm2]

Test current

[A]

0.2

0.5

0.75

4

6

9

1.0

1.5

13.5

17.5

2.5
24

4

6

10

16

32

41

57

76

Technical information
Overview of certification bodies and
safety marks

Certification bodies and approvals

Country
code

X

j

IECEE CB Scheme
(in combination with certifying body)

Internatio
nal

f

CCA

CENELEC Certification Agreement (CCA
inspection report)
(in combination with certifying body)

EU

C

Canadian Standards Association (CSA)

N
A

Country
code

Ship classification societies

Country
code

FM Approvals

US

v

Bureau Veritas

FR



DEKRA Certification B.V.

NL

F

Germanischer Lloyd AG

DE

CA

p

Physikalisch-Technische Bundesanstalt

DE

x

Lloyd's Register EMEA

GB

Underwriters Laboratories Inc. (UL)

US



QS Schaffhausen

CH

m

Nippon Kaiji Kyokai

JP

n
a

Underwriters Laboratories Inc. (UL)
- UL approval for Canada -

CA

!

VTT Expert Services Oy

FI

o

Det Norske Veritas

NO

U
u

Underwriters Laboratories Inc. (UL)
Combined logo
- UL approval for the USA and Canada -

US
CA



IBExU Institut für Sicherheitstechnik
GmbH

DE

z

Polski Rejestr Statków

PL

g

INSIEME PER LA QUALITA'E LA
SICUREZZA

IT

w

TÜV Rheinland do Brasil

BR

y

Russian Maritime Register of Shipping

RU

P

Gosudarstvenne Komitet Standartov
(GOST)

RU

N
A

Underwriters Laboratories Inc. (UL)

US

d

Korean Register of Shipping

KR



DEKRA Certification B.V.

NL

$

TÜV Nord

DE

l

American Bureau of Shipping

US

K

Österreichischer Verband für
Elektrotechnik

AT



DEKRA EXAM GmbH

DE

S

South African Bureau of Standards

ZA

s

electrosuisse SEV Verband für Elektro-,
Energie- und Informationstechnik

CH

J
V

Verband Deutscher Elektrotechniker
e.V.(VDE)
– Approval of drawings
– Reports with production monitoring

DE

h

Berufsgenossenschaft (BG)
GS - Geprüfte Sicherheit

DE

T

TÜV Rheinland Industrie Service GmbH

DE

Explosion protection

EMC: Class A product:
In accordance with statutory
regulations, our products are indicated with
this footnote if they are intended for use in
industrial environments. This means that
the permissible limit values for residential
applications may be exceeded in the event
of conducted and emitted interference. In
such cases, the operator may have to take
additional safety measures in order to
ensure electromagnetic compatibility in
residential applications.

Note:
Subject to changes that serve the
purpose of technical progress.

PHOENIX CONTACT

287

Technical information
Dimensioning of clearances

Rated surge voltages for items that are directly supplied by
the low-voltage network (extract from Table 1)
Nominal voltage of the power supply
system 1) (mains) acc. to IEC 60038 3)
[V]

Schematic for determining clearances

Three-phase

Single-phase

[V]

120 to 240

50
100
150
300
600
1000

Nominal voltage of the
power supply
230/400 277/480
400/690
1000
Rated
surge
voltage

Rated surge
voltage according to
Table 1

Minimum clearance L
according to Table 2

Height
> 2000 m
above sea

Surge
voltage
test

Surge
voltage
category

No
Rating acc.
to case A

Altitude correction factors
(extract from Table A.2)
Multiplication factor
for gaps

2000
3000
4000

80.0
70.0
62.0

1.00
1.14
1.29

5000
6000
7000

54.0
47.0
41.0

1.48
1.70
1.95

8000
9000
10000

35.5
30.5
26.5

2.25
2.62
3.02

15000
20000

12.0
5.5

6.67
14.50

PHOENIX CONTACT

II

III

IV

500
800
1500
2500
4000
6000

800
1500
2500
4000
6000
8000

1500
2500
4000
6000
8000
12000

Refer to Appendix B for application in existing deviating low-voltage networks and their nominal voltages.

2)

Items with this rated surge voltage may be used in systems in accordance with IEC 60364-4-443.

3)

The slash, i.e., /, indicates a three-phase 4-conductor system. The lower value is the conductor-to-neutral conductor voltage,
whereas the higher value is the conductor-to-conductor voltage. When only one value is specified, it refers to a three-phase 3conductor system, and indicates the conductor-to-conductor voltage.

4)

Refer to 2.2.2.1.1 for an explanation of surge voltage categories.

Required impulse
withstand
voltage 1) 5)

Clearance L

288

I
330
500
800
1500
2500
4000

Minimum clearances for surge voltages (extract from Table 2)

Multiply L with altitude
correction factor
according to Table A2

Normal air pressure
in kPa

Surge voltage category 4)

1)

Pollution
degree

Yes

Height
in m

Rated surge voltage 2)
[V]

Conductor-neutral conductor voltage
derived from the total nominal
AC voltage or nominal DC voltage

Condition A
Non-homogeneous field (refer to 1.3.15)
1
[mm]
0.01
0.02
0.04
0.06
0.10
0.15
0.25
0.5
1.0
1.5
2.0
3
4
5.5
8
11
14
18
25
33
40
60
75
90
130
170

Pollution degree 6)
2
3
[mm]
[mm]

Condition B
Homogeneous field (refer to 1.3.14)
1
[mm]
0.01
0.02
0.04
0.06
0.10
0.15
0.2
0.3
0.45
0.6
0.8
1.2
1.5
2
3
3.5
4.5
5.5
8
10
12.5
17
22
27
35
45

Pollution degree 6)
2
3
[mm]
[mm]

0.33 2)
0.40
0.2 3) 4)
0.5 2)
0.2 3) 4)
0.60
0.8 4)
0.8 4)
0.80 2)
1.0
1.2
0.25
0.5
0.3
1.5 2)
2.0
1.0
1.0
0.45
1.5
1.5
0.6
2.5 2)
3.0
2.0
2.0
0.8
3
3
1.2
1.2
4.0 2)
5.0
4
4
1.5
1.5
5.5
5.5
2
2
6.0 2)
8
8
3
3
8.0 2)
10
11
11
3.5
3.5
14
14
4.5
4.5
12 ,2)
15
18
18
5.5
5.5
20
25
25
8
8
25
33
33
10
10
30
40
40
12.5
12.5
40
60
60
17
17
50
75
75
22
22
60
90
90
27
27
80
130
130
35
35
100
170
170
45
45
1) This voltage is:
– For function insulation: the highest surge voltage expected for the clearance
– For basic insulation, if influenced directly or considerably by surge voltages from the low-voltage network:
the item's rated surge voltage
– For a different basic insulation: the highest surge voltage possible in the circuit
2) Preferred values
3) For PCBs, the values of pollution degree 1 are applicable, except that no deviation below the value of 0.04 mm is permitted, as
specified in Table 4.
4) Minimum clearances for pollution degrees 2 and 3 are based on the corresponding creepage distances. This resistance is reduced
due to the effects of humidity.
5) Values can be interpolated for parts or circuits within items that are subjected to surge voltages.
6) The distances for pollution degree 4 are equal to those for pollution degree 3, except that the minimum clearance is 1.6 mm.

Technical information
Dimensioning of creepage distances
Single-phase 3 or 2-conductor AC or DC voltage
systems (extract from Table 3a)
Nominal
voltage of the
power supply
system
(mains) *)

Schematic for determining creepage
distances
Nominal mains
voltage of the power

Rated AC/DC voltage
Insulation

Pollution
degree

Minimum creepage
distance K acc. to

Pollution degree 1

Clearance L
Yes
Increase K
to L

No

Yes
K

Navigation menu