Report Number: 02E0683-E
December 5, 2002
Page 1 of 66
Rev. 00
EMC COMPLIANCE TEST REPORT
for
KEYBOARD
Trade Name : Tai-Hao; Clicker
Model Number : F21 XP SERIES
F21XP2 / F21XP1 / F21XP3 / F21XP5 / F21XP10 / F21XP7
Serial Number : N/A
Report Number : 02E0683-E
Date : December 5, 2002
Regulations : See below
Standards Results (Pass/Fail)
EN 55022: 1998
EN 61000-3-2: 1995+A1: 1998+A2: 1998+A14: 2000
EN 61000-3-3: 1995
EN 55024: 1998
- IEC 61000-4-2: 1995 +A2: 2001
- IEC 61000-4-3: 1995
- IEC 61000-4-4: 1995
- IEC 61000-4-5: 1995
- IEC 61000-4-6: 1996
- IEC 61000-4-8: 1993
- IEC 61000-4-11: 1994
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
N/A
PASS
Prepared for
TAIWAN TAI-HAO ENTERPRISE CO., LTD.
6F-5, NO. 155, KEELUNG RD., SEC. 1,
TAIPEI TAIWAN
Prepared by
C&C LABORATORY CO., LTD.
#B1, 1st Fl., Universal Center,
No. 183, Sec. 1, Tatung Rd., Hsi Chin,
Taipei Hsien, Taiwan, R.O.C.
TEL: (02)86422071
FAX: (02)86422256
This report shall not be reproduced, except in full, without the written approval of
C&C Laboratory Co., Ltd.
Report Number: 02E0683-E
December 5, 2002
Page 2
Rev. 00
EC-Declaration of Conformity
For the following equipment:
KEYBOARD
( Product Name )
F21 XP SERIES
F21XP2 / F21XP1 / F21XP3 / F21XP5 / F21XP10 / F21XP7
( Model Designation / Trade name )
TAIWAN TAI-HAO ENTERPRISE CO., LTD.
( Manufacturer Name )
6F-5, NO. 155, KEELUNG RD., SEC. 1, TAIPEI TAIWAN
(Manufacturer Address)
is herewith confirmed to comply with the requirements set out in the Council Directive on the
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive
(89/336/EEC, Amended by 92/31/EEC, 93/68/EEC & 98/13/EC), For the evaluation regarding the
Electromagnetic Compatibility (89/336/EEC, Amended by 92/31/EEC & 93/68/EEC & 98/13/EC ) the
following standards are applied:
V EN 55022: 1998
V EN 61000-3-2: 1995+A1: 1998+A2: 1998+A14: 2000
V EN 61000-3-3: 1995
V EN55024: 1998
IEC 61000-4-2: 1995 +A2: 2001, IEC 61000-4-3: 1995, IEC 61000-4-4: 1995
IEC 61000-4-5: 1995, IEC 61000-4-6: 1996, IEC 61000-4-11: 1994
The following manufacturer / importer or authorized representative established within the EUT is
responsible for this declaration:
( Company Name )
( Company Address )
Person responsible for making this declaration:
( Name, Surname )
( Position / Title )
( Place ) ( Date ) ( Legal Signature )
Report Number: 02E0683-E
December 5, 2002
Page 3
Rev. 00
TABLE OF CONTENTS
DESCRIPTION PAGE
VERIFICATION OF COMPLIANCE 5
GENERAL INFORMATION 6
SYSTEM DESCRIPTION 7
PRODUCT INFORMATION 8
SUPPORT EQUIPMENT 9
TEST FACILITY 10
TEST EQUIPMENT 11
SECTION 1 EN 55022(LINE CONDUCTED & RADIATED
EMISSION) 14
MEASUREMENT PROCEDURE & LIMIT (LINE CONDUCTED
EMISSION TEST)
14
MEASUREMENT PROCEDURE & LIMIT (COMMON MODE
CONDUCTED EMISSION MEASUREMENT)
16
MEASUREMENT PROCEDURE & LIMIT (RADIATED EMISSION
TEST)
17
BLOCK DIAGRAM OF TEST SETUP
19
SUMMARY DATA
20
SECTION 2 EN61000-3-2 & EN 61000-3-3 (POWER HARMONICS
& VOLTAGE FLUCTUATION/FLICKER) 22
BLOCK DIAGRAM OF TEST SETUP
22
RESULT
22
SECTION 3 IEC 61000-4-2 (ELECTROSTATIC DISCHARGE)
33
BLOCK DIAGRAM OF TEST SETUP
33
TEST PROCEDURE
34
PERFORMANCE & RESULT
34
SECTION 4 IEC 61000-4-3 (RADIATED ELECTROM
AGNETIC FIELD)
38
BLOCK DIAGRAM OF TEST SETUP
38
TEST PROCEDURE
39
PERFORMANCE & RESULT
40
Report Number: 02E0683-E
December 5, 2002
Page 4
Rev. 00
DESCRIPTION PAGE
SECTION 5 IEC 61000-4-4 (FAST TRANSIENTS/BURST) 41
BLOCK DIAGRAM OF TEST SETUP 41
TEST PROCEDURE 42
PERFORMANCE & RESULT 42
SECTION 6 IEC 61000-4-5 (SURGE IMMUNITY) 43
BLOCK DIAGRAM OF TEST SETUP 43
TEST PROCEDURE 44
PERFORMANCE & RESULT 44
SECTION 7 IEC 61000-4-
6 (CONDUCTED DISTURBANCE,
INDUCED BY RADIO-FREQUENCY FIELDS) 45
BLOCK DIAGRAM OF TEST SETUP 45
TEST PROCEDURE 47
PERFORMANCE & RESULT 47
SECTION 8 IEC 61000-4-8 (Power Frequency Magnetic Field)) 48
BLOCK DIAGRAM OF TEST SETUP 48
TEST PROCEDURE 49
PERFORMANCE & RESULT 49
SECTION 9 IEC 61000-4-11 (VOLTAGE DIP/INTERRUPTION) 50
BLOCK DIAGRAM OF TEST SETUP 50
TEST PROCEDURE 51
PERFORMANCE & RESULT 51
APPENDIX 1 PHOTOGRAPHS OF TEST SETUP 52
EN 55022 TEST
EN 61000-3-2 TEST
EN 61000-3-3 TEST
IEC 61000-4-2 TEST
IEC 61000-4-3 TEST
IEC 61000-4-4 TEST
IEC 61000-4-5 TEST
IEC 61000-4-6 TEST
IEC 61000-4-11 TEST
APPENDIX 2 PHOTOGRAPHS OF EUT 62
APPENDIX 3 CONDUCTED EMISSION PLOT & RADIATED
EMISSION DATA
64
Report Number: 02E0683-E
December 5, 2002
Page 5
Rev. 00
VERIFICATION OF COMPLIANCE
Equipment Under Test: KEYBOARD
Trade Name: Tai-Hao; Clicker
Model Number: F21 XP SERIES
F21XP2 / F21XP1 / F21XP3 / F21XP5 / F21XP10 / F21XP7
Serial Number: N/A
Applicant: TAIWAN TAI-HAO ENTERPRISE CO., LTD.
6F-5, NO. 155, KEELUNG RD., SEC. 1,
TAIPEI TAIWAN
Manufacturer: TAIWAN TAI-HAO ENTERPRISE CO., LTD.
6F-5, NO. 155, KEELUNG RD., SEC. 1,
TAIPEI TAIWAN
Type of Test: EMC Directive 89/336/EEC for CE Marking
Technical Standards: EN 55022: 1998
EN 61000-3-2: 1995+A1: 1998+A2: 1998+A14: 2000
EN 61000-3-3: 1995
EN 55024: 1998
(IEC 61000-4-2: 1995 +A2: 2001, IEC 61000-4-3: 1995
IEC 61000-4-4: 1995, IEC 61000-4-5: 1995
IEC 61000-4-6: 1996, IEC 61000-4-11: 1994)
File Number: 02E0683-E
Date of test: December 4, 2002
Deviation: None
Condition of Test Sample: Normal
Final Result: Pass
Worst data: See below
Test Item Freq. Measured data Margin (MìC) Remark
Radiated Emission 180.350 (MHz) 26.13 (dBìV/m) -3.87dB (± 3.3498 dB) Vertical
Conducted Emission 0.258 (MHz) 50.97 (dBìV) -10.54dB (± 2.8108 dB) Neutral
l The negative sign in Margin cell means under the specific limit.
l This test result traceable to national or international standards
The above equipment was tested by C&C Laboratory Co., Ltd. for compliance with the requirements
set forth in EMC Directive 89/336/EEC and the Technical Standards mentioned above. This said
equipment in the configuration described in this report shows the maximum emission levels emanating
from equipment and the level of the immunity endurance of the equipment are within the compliance
requirements.
The test results of this report relate only to the tested sample identified in this report.
Approved by Authorized Signatory:
James Chan / Manager
Report Number: 02E0683-E
December 5, 2002
Page 6
Rev. 00
GENERAL INFORMATION
Applicant: TAIWAN TAI-HAO ENTERPRISE CO., LTD.
6F-5, NO. 155, KEELUNG RD., SEC. 1,
TAIPEI TAIWAN
Contact Person: Kelly Wang
Manufacturer: TAIWAN TAI-HAO ENTERPRISE CO., LTD.
6F-5, NO. 155, KEELUNG RD., SEC. 1,
TAIPEI TAIWAN
File Number: 02E0683-E
Date of Test: December 4, 2002
Equipment Under Test: KEYBOARD
Trade Name: Tai-Hao; Clicker
Model Number: F21 XP SERIES
F21XP2 / F21XP1 / F21XP3 / F21XP5 / F21XP10 / F21XP7
Serial Number: N/A
Type of Test: EMC Directive 89/336/EEC for CE Marking
Technical Standards: EN 55022: 1998
EN 61000-3-2: 1995+A1: 1998+A2: 1998+A14: 2000
EN 61000-3-3: 1995
EN 55024: 1998
(IEC 61000-4-2: 1995 +A2: 2001, IEC 61000-4-3: 1995
IEC 61000-4-4: 1995, IEC 61000-4-5: 1995
IEC 61000-4-6: 1996, IEC 61000-4-11: 1994)
Frequency Range
(EN 55022): 150kHz to 30MHz for Line Conducted Test
30MHz to 1000MHz for Radiated Emission Test
Test Site
C&C LABORATORY CO., LTD.
No. 199, Chung Sheng Road, Hsin Tien City, Taipei
Taiwan, R. O. C.
Report Number: 02E0683-E
December 5, 2002
Page 7
Rev. 00
SYSTEM DESCRIPTION
EUT Test Procedure:
1. Windows 98 Boots System.
2. Run Emctest.exe & Emitest.exe To Activate All Peripherals And Display “H” Pattern On Monitor
Screen.
Report Number: 02E0683-E
December 5, 2002
Page 8
Rev. 00
PRODUCT INFORMATION
Housing Type: Plastic
EUT Power Rating: DC 5V from Host PC
AC power during Test: 230VAC, 50Hz to Host PC Power Supply
Power Supply Manufacturer: Line-on
Power Supply Model Number: PS-5141-6G
AC Power Cord Type: Unshielded, 1.8m (Detachable)
EUT I/O Cable Type: Unshielded, 1.3m (Detachable, with a core)
OSC/Clock Frequency
N/A
Model Differences:
Model Name Differences Tested
(Checked)
Original F21 XP SERIES
Additional
F21XP2 / F21XP1 /
F21XP3 / F21XP5 /
F21XP10 / F21XP7
COLOR DIFFERENCE FOR KB
KEY CAPS&CASING
I/O Port of EUT:
I/O PORT TYPES Q’TY TESTED WITH
1). PS/2 KEYBOARD PORT 1 1
Note: N/A
Report Number: 02E0683-E
December 5, 2002
Page 9
Rev. 00
SUPPORT EQUIPMENT
Peripherals Devices:
No Equipment Model
#
Serial
#
FCC/ BSMI
ID
Trade Name Data
Cable Power
Cord
1. PS/2
Mouse M-S34 LZED1303050 DZL211029
BSMI ID:4862A011 LOGITECH Shielded,
1.9m N/A
2. Modem 5JEG4033MKO L0063CG2D0071
90 5RJTAI-35500-M5-E TOP-
SOLUTION
Shielded,
0.8 m
Unshielded,
1.8m
3. Host PC EVOD300 6K1BKF83F2ZD DoC
BSMI ID:3892Q094 COMPAQ
Unshielded,
1.3m
with a core
Unshielded,
1.8m
4. Monitor RB17NS N/A DoC
BSMI ID:3902B332 SAMSUNG Shielded,
1.8m
with two cores
Unshielded,
1.8m
with a core
5. Printer EPSONSTYLU
SC20SX EW4E126644 BSMI ID:3902E004 EPSON Shielded,
1.8 m
Unshielded,
1.8m
Note: All the above equipment/cables were placed in worse case positions to maximize emission
signals.
Grounding: Grounding was in accordance with the manufacturer’s requirements and conditions
for the intended use.
Report Number: 02E0683-E
December 5, 2002
Page 10
Rev. 00
TEST FACILITY
Location: No. 199, Chung Sheng Road, Hsin Tien City,
Taipei, Taiwan, R. O. C.
Description: There are two 3/10m open area test sites and one line conducted lab for
final test.
The Open Area Test Sites and the Line Conducted labs are constructed
and calibrated to meet the FCC requirements in documents ANSI C63.4:
1992 and CISPR 22/EN 55022 requirements.
Site Filing: A site description is on file with the Federal Communications
Commission, 7435 Oakland Mills Road, Columbia, MD 21046.
Registration also was made with Voluntary Control Council for
Interference (VCCI). Registration No. R-1434/ C-1511
Site Accreditation: Accredited by A2LA (Certificate #: 824.01) for EMC.
Also accredited by BSMI for the product category of Information
Technology Equipment.
Instrument Tolerance: All measuring equipment is in accord with ANSI C63.4 and CISPR 22
requirements that meet industry regulatory agency and accreditation
agency requirement.
Ground Plane: Two conductive reference ground planes were used during the Line Conducted
Emission, one in vertical and the other in horizontal. The dimensions of these ground planes are as
below. The vertical ground plane was placed distancing 40 cm to the rear of the wooden test table on
where the EUT and the support equipment were placed during test. The horizontal ground plane
projected 50 cm beyond the footprint of the EUT system and distanced 80 cm to the wooden test table.
For Radiated Emission Test, one horizontal conductive ground plane extended at least 1m beyond the
periphery of the EUT and the largest measuring antenna, and covered the entire area between the EUT
and the antenna. It has no holes or gaps having longitudinal dimensions larger than one-tenth of a
wavelength at the highest frequency of measurement up to 1GHz.
Report Number: 02E0683-E
December 5, 2002
Page 11
Rev. 00
TEST EQUIPMENT LIST (EMISSION)
Instrumentation: The following list contains equipment used at C & C Laboratory Co., Ltd. for
testing. The equipment conforms to the CISPR 16-1 / ANSI C63.2-1988 Specifications for
Electromagnetic Interference and Field Strength Instrumentation from 9kHz to 1.0 / 2.0 GHz.
Equipment used during the tests:
Open Area Test Site: #D
EQUIPMENT
TYPE MFR MODEL
NUMBER SERIAL
NUMBER LAST
CAL. CAL.
DUE
EMC
ANALYZER HP 8595EM 3412A00104 03/01/02 02/28/03
AMPLIFIER HP 8447DB 1644A02328 05/05/02 05/04/03
ANTENNA SCHWARZBECK VULB 9160 3104 05/12/02 05/11/03
CABLE BELDEN 9913 N-TYPE08 04/17/02 04/16/03
Conducted Area Test Site: Conducted Room
EQUIPMENT
TYPE MFR MODEL
NUMBER SERIAL
NUMBER LAST
CAL. CAL.
DUE
TEST
RECEIVER R&S ESHS20 840455/006 03/16/02 03/15/03
LISN EMCO 3825/2 1842 01/11/02 01/10/03
LISN(EUT) EMCO 3825/2 1435 01/16/02 01/15/03
The calibrations of the measuring instruments, including any accessories that may effect such
calibration, are checked frequently to assure their accuracy. Adjustments are made and correction
factors applied in accordance with instructions contained in the manual for the measuring instrument.
Report Number: 02E0683-E
December 5, 2002
Page 12
Rev. 00
TEST EQUIPMENT LIST
For Power Harmonic & Voltage Fluctuation/Flicker Measurement:
Manufacturer/Type Model No. Serial No. Last Cal. Cal. Due
HP /
Harmonic & Flicker Tester 6842A 3531A-000142 06/18/2002 06/17/2003
For ESD test:
Manufacturer/Type Model No. Serial No. Last Cal. Cal. Due
Schaffner /
ESD Simulator NSG 432 2029 02/06/2002 02/05/2003
For Radiated Electromagnetic Field immunity Measurement:
Manufacturer/Type Model No. Serial No. Last Cal. Cal. Due
R&S / Signal Generator SMY 02 DE13751 01/10/2002 01/09/2003
IFI /
“E” Field sensor/ Light
Modulator Transmitter
EFS-5 713-0695 06/28/2002 06/27/2003
IFI / Combination Amplifier SMX100 2067-1196 No Calibration
Required No Calibration
Required
IFI / Leveling Pre-Amplifier LPA-5B 714-0695 No Calibration
Required No Calibration
Required
EMCO / Biconilog Antenna 3142 9609-1087 No Calibration
Required No Calibration
Required
For Fast Transients/Burst test:
Manufacturer/Type Model No. Serial No. Last Cal. Cal. Due
KeyTek Instruments /
EFT Generator E421 9502326 10/01/2002 09/30/2003
KeyTek Instruments /
Capacitive Clamp CCL-4 9503290 No Calibration
Required No Calibration
Required
For Surge Immunity test:
Manufacturer/Type Model No. Serial No. Last Cal. Cal. Due
KeyTek Instruments/
Surger Generator E501 9502324 10/01/2002 09/30/2003
Telecom Lines Coupler
DECOUPLER
KeyTek Instruments
CM-TELCD 0104399 No Calibration
Required No Calibration
Required
I/O Signal Line
DECOUPLER
KeyTek Instruments
CM-I/OCD 0103234 No Calibration
Required No Calibration
Required
Report Number: 02E0683-E
December 5, 2002
Page 13
Rev. 00
For CS test:
Manufacturer/Type Model No. Serial No. Last Cal. Cal. Due
R&S / Signal Generator SMY 02 DE13751 01/10/2002 01/09/2003
IFI / Combination Amplifier SMX100 2067-1196 No Calibration
Required No Calibration
Required
IFI / Leveling Pre-Amplifier LPA-5B 714-0695 No Calibration
Required No Calibration
Required
FISCHER /
Power Line Coupling
Decoupling Network
FCC-801-M3-16A
99122 11/02/2002 11/01/2003
FISCHER /
Bulk Current Injection Probe F-120-9B 54 11/02/2002 11/01/2003
Narda /
High Power Attenuator 769-6 02541 No Calibration
Required No Calibration
Required
For Power Frequency Magnetic Field test :
Manufacturer/Type Model No. Serial No. Last Cal. Cal. Due
Haefely /
Magic Field Tester MAG 100.1 081436-02 No Calibration
Required No Calibration
Required
Extech Electronics /
Frequency Converter CFC-105 810390 No Calibration
Required No Calibration
Required
CHY/
AC/DC Clamp Meter 932C 2K0900285 10/24/2002 10/23/2003
For Voltage Dips/Short Interruption and Voltage Variation Immunity test:
Manufacturer/Type Model No. Serial No. Last Cal. Cal. Due
Haefely /
Dips/Inerruption/Variations
Tester
PLINE 1610 081568-06 04/25/2002 04/24/2003
FLUKE /
79 Series Ii Multimeter 79-II
66400868
07/02/2002 07/01/2003
Report Number: 02E0683-E
December 5, 2002
Page 14
Rev. 00
SECTION 1 EN 55022 (LINE CONDUCTED & RADIATED EMISSION)
MEASUREMENT PROCEDURE
(PRELIMINARY LINE CONDUCTED EMISSION TEST)
1) The equipment was set up as per the test configuration to simulate typical actual usage per the
user’s manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is
used and is placed on the ground plane as per EN 55022 (see Test Facility for the dimensions of
the ground plane used). When the EUT is a floor-standing equipment, it is placed on the
ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground
plane.
2) Support equipment, if needed, was placed as per EN 55022.
3) All I/O cables were positioned to simulate typical actual usage as per EN 55022.
4) The EUT received DC 5V power through Host PC and Line Impedance Stabilization Network
(LISN) which supplied power source of 230VAC/ 50Hz and was grounded to the ground plane.
5) All support equipment received power from a second LISN supplying power of 110VAC/60Hz, if
any.
6) The EUT test program was started. Emissions were measured on each current carrying line of
the EUT using a spectrum analyzer / Receiver connected to the LISN powering the EUT. The
LISN has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were
taken: one with Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load;
the second scan had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer /
Receiver.
7) Analyzer / Receiver scanned from 150kHz to 30MHz for emissions in each of the test modes.
8) During the above scans, the emissions were maximized by cable manipulation.
9) The following test mode were scanned during the preliminary test:
Mode:
1 NORMAL MODE
10) After the preliminary scan, we found the following test mode producing the highest emission
level.
Mode: 1.
Then, the EUT configuration and cable configuration of the above highest emission level were
recorded for reference of final testing.
Report Number: 02E0683-E
December 5, 2002
Page 15
Rev. 00
MEASUREMENT PROCEDURE
(FINAL LINE CONDUCTED EMISSION TEST)
1) EUT and support equipment was set up on the test bench as per step 10 of the preliminary test.
2) A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest
emissions. Emission frequency and amplitude were recorded into a computer in which correction
factors were used to calculate the emission level and compare reading to the applicable limit. If
EUT emission level was less 2dB to the A.V. limit in Q.P. mode, then the emission signal was
re-checked using an A.V. detector.
3) The test data of the worst case condition(s) was reported on the Summary Data page.
Data Sample:
Freq
(MHz)
Meter
Reading
(dBuV)
C.F.
(dB)
Corrected
Reading
(dBuV)
Limits
(dBuV)
Margin
(dB)
Reading
Type
(P/Q/A)
Line
(L1/L2)
x.xx x.xx x.xx 38.38 56.00 -17.62 P L1
C.F.(Correction Factor)=Insertion Loss + Cable Loss
Corrected Reading = Metering Reading + C.F.
Margin=Corrected Reading - Limits
P=Peak Reading L1=Hot
Q=Quasi-peak L2=Neutral
A=Average Reading
Comments: N/A
Calculation example:
Margin (dB) = Corrected Reading (dBuV) Limit (dBuV)
LINE CONDUCTED EMISSION LIMIT (EN 55022)
Frequency Maximum RF Line Voltage
Q.P. AVERAGE
150kHz-500kHz 66-56dBuV 56-46dBuV
500kHz-5MHz 56dBuV 46dBuV
5MHz-30MHz 60dBuV 50dBuV
Note: The lower limit shall apply at the transition frequency.
Report Number: 02E0683-E
December 5, 2002
Page 16
Rev. 00
MEASUREMENT PROCEDURE
(COMMON MODE CONDUCTED EMISSION MEASUREMENT)
1) Selecting ISN for unscreened cable or a current probe for screened cable to take measurement.
2) The port of the EUT was connected to the remote side support equipment through the ISN/Current
Probe and communication in normal condition.
3) Making a overall range scan by using the test receiver controlled by controller and record at least
six highest emissions for showing in the test report.
4) Emission frequency and amplitude were recorded into a computer in which correction factors were
used to calculate the emission level and compare reading to the applicable limit.
5) In case of measuring on the screened cable, the current limit shall be applied, otherwise the voltage
limit should be applied.
6) The following test mode(s) were scanned during the preliminary test:
Mode: N/A (EUT no any Telecommunicate Port)
7) After the preliminary scan, we found the following test mode(s) producing the highest emission
level and test date of the worst case was reported on the summary data page.
Mode: N/A
Data Sample:
Freq
(MHz) Meter Reading
(dBuV) C.F.
(dB) Corrected Reading
(dBuV/m) Limits
(dBuV/m) Margin
(dB) Reading Type
(P/Q/A)
x.xx x.xx x.xx 59.26 74.00 -14.74 P
C.F.(Correction Factor)=Insertion Loss (9.5dB) + Cable Loss
Corrected Reading = Metering Reading + C.F.
Margin=Corrected Reading - Limits
P=Peak Reading Q=Quasi-peak A=Average Reading
Comments: N/A
COMMON MODE CONDUCTED EMISSION LIMIT
AT TELECOMMUNICATION PORTS
CE-Mark ( EN 55022:1998 )
CLASS Measuring Voltage limit dB(uV) Current limit dB(uA)
Band Q.P. AV Q.P. AV
150kHz-500kHz 84-74 74-64 40-30 30-20
B 500kHz-30MHz 74 64 30 20
Note: The lower limit shall apply at the transition frequency.
Report Number: 02E0683-E
December 5, 2002
Page 17
Rev. 00
MEASUREMENT PROCEDURE
(PRELIMINARY RADIATED EMISSION TEST)
1) The equipment was set up as per the test configuration to simulate typical actual usage per the
user’s manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8
meters is used which is placed on the ground plane as per EN 55022 (see Test Facility for the
dimensions of the ground plane used). When the EUT is a floor-standing equipment, it is placed
on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the
ground plane.
2) Support equipment, if needed, was placed as per EN 55022.
3) All I/O cables were positioned to simulate typical actual usage as per EN 55022.
4) The EUT received DC 5V power source from Host PC Power Supply (AC 230V/50Hz) to the
outlet socket under the turntable. All support equipment received 110VAC/60Hz power from
another socket under the turntable, if any.
5) The antenna was placed at 10 meter away from the EUT as stated in EN 55022. The antenna
connected to the analyzer via a cable and at times a pre-amplifier would be used.
6) The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test program was
started. Emissions were scanned and measured rotating the EUT to 360 degrees and positioning
the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal
polarization, to maximize the emission reading level.
7) The following test mode were scanned during the preliminary test:
Mode:
1 NORMAL MODE
8) After the preliminary scan, we found the following test mode producing the highest emission level.
Mode: 1.
Then, the EUT and cable configuration, antenna position, polarization and turntable position of the
above highest emission level were recorded for final testing.
Report Number: 02E0683-E
December 5, 2002
Page 18
Rev. 00
MEASUREMENT PROCEDURE
(FINAL RAIDATED EMISSION TEST)
1) EUT and support equipment were set up on the turntable as per step 8 of the preliminary test.
2) The Analyzer / Receiver scanned from 30MHz to 1000MHz. Emissions were scanned and
measured rotating the EUT to 360 degrees, varying cable placement and positioning the antenna 1
to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to
maximize the emission reading level.
3) Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position,
polarization and turntable position were recorded into a computer in which correction factors were
used to calculate the emission level and compare reading to the applicable limit and only Peak
reading is presented. If EUT emission level was less-2dB to the limit, then the emission signal was
re-checked using a Q.P. detector.
4) The test data of the worst case condition(s) was reported on the Summary Data page.
Data Sample:
Freq
(MHz)
Meter
Reading
(dBuV)
C.F.
(dB/m)
Corrected
Reading
(dBuV/m)
Limits
(dBuV/m)
Margin
(dB)
Reading
Type
P/Q/A
Pol.
H/V
x.xx x.xx x.xx 30.82 37.00 -5.18 P V
C.F.(Correction Factor)=Antenna Factor + Cable Loss + Attenuator(3/6dB) - Amplifier Gain
Corrected Reading = Metering Reading + C.F.
Margin=Corrected Reading Limits
P=Peak Reading H=Horizontal Polarization/Antenna
Q=Quasi-peak V=Vertical Polarization/Antenna
A=Average Reading
Comments: N/A
Calculation example:
Margin (dB) = Corrected Reading (dBuV/m) Limits (dBuV/m)
Corrected Reading (dBuV/m)=Metering Reading (dBuV) + Corr Factor (dB/m)
RADIATED EMISSION LIMIT
Frequency
(MHz) Distance
(m) Maximum Field Strength Limit
(dBu V/m/ Q.P.)
30-230 10 30
230-1000 10 37
Note: The lower limit shall apply at the transition frequency.
Report Number: 02E0683-E
December 5, 2002
Page 19
Rev. 00
BLOCK DIAGRAM OF TEST SETUP
System Diagram of Connections between EUT and Simulators
EUT: KEYBOARD
Trade Name: Tai-Hao; Clicker
Model Number: F21 XP SERIES
EUT
2.Modem
3.Host PC 4.Monitor 5.Printer
1.PS/2
Mouse
Report Number: 02E0683-E
December 5, 2002
Page 20
Rev. 00
SUMMARY DATA
(LINE CONDUCTED TEST)
Model Number: F21 XP SERIES Location: Conducted Room
Tested by: Jimmy Chen
Test Mode: Mode 1
Test Results: Passed
Temperature: 30 Humidity: 61%RH
(The chart below shows the highest readings taken from the final data)
Frequency Range Investigated (150 kHz TO 30 MHz)
Freq
(MHz)
Meter
Reading
(dBuV)
C.F.
(dB)
Corrected
Reading
(dBuV)
Limits
(dBuV)
Margin
(dB)
Reading
Type
(P/Q/A)
Line
(L1/L2)
0.258 46.72 0.04 46.76 61.51 -14.75 P L1
0.555 40.80 0.07 40.87 56.00 -15.13 P L1
0.994 41.13 0.10 41.23 56.00 -14.77 P L2
0.258 50.93 0.04 50.97 61.51 -10.54 P L2
0.555 42.24 0.07 42.31 56.00 -13.69 P L2
0.994 42.01 0.10 42.11 56.00 -13.89 P L2
C.F.(Correction Factor)=Insertion Loss + Cable Loss
Corrected Reading = Metering Reading + C.F.
Margin=Corrected Reading - Limits
P=Peak Reading L1=Hot
Q=Quasi-peak L2=Neutral
A=Average Reading
Comments: N/A
Report Number: 02E0683-E
December 5, 2002
Page 21
Rev. 00
SUMMARY DATA
(RADIATED EMISSION TEST)
Model Number: F21 XP SERIES Location: Site # D
Tested by: Jimmy Chen Polar: Vertical / Horizontal 10m
Test Mode: Mode 1
Test Results: Passed
Temperature: 25 Humidity: 61%RH
(The chart below shows the highest readings taken from the final data)
Frequency Range Investigated (30 MHz TO 1000 MHz)
Freq
(MHz)
Meter
Reading
(dBuV)
C.F.
(dB/m)
Corrected
Reading
(dBuV/m)
Limits
(dBuV/m)
Margin
(dB)
Reading
Type
P/Q/A
Pol.
H/V
39.180 34.45 -9.65 24.80 30.00 -5.20 P V
48.030 34.20 -8.09 26.12 30.00 -3.89 P V
120.050 32.88 -9.01 23.87 30.00 -6.13 P V
180.350 34.32 -8.19 26.13 30.00 -3.87 P V
498.880 31.19 0.89 32.08 37.00 -4.92 P V
500.350 31.43 0.90 32.33 37.00 -4.67 Q H
C.F.(Correction Factor)=Antenna Factor + Cable Loss - Amplifier Gain ( + Attenuator 6dB)
Corrected Reading = Metering Reading + C.F.
Margin=Corrected Reading - Limits
P=Peak Reading H=Horizontal Polarization/Antenna
Q=Quasi-peak V=Vertical Polarization/Antenna
A=Average Reading
Comments: N/A
Report Number: 02E0683-E
December 5, 2002
Page 22
Rev. 00
SECTION 2 EN 61000-3-2 & EN 61000-3-3 (POWER HARMONICS &
VOLTAGE FLUCTUATION / FLICKER)
POWER HARMONICS MEASUREMENT
Port : AC mains
Basic Standard : EN 61000-3-2 (1995+A1: 1998+A2: 1998 + A14: 2000)
Limits : Class A, V Class D
Temperature : 210C
Humidity : 58%
Test By : Jimmy Chen
VOLTAGE FLUCTUATION/FLICKER MEASUREMENT
Port : AC mains
Basic Standard : EN 61000-3-3 (1995)
Limits : §5 of EN 61000-3-3
Temperature : 210C
Humidity : 58%
Test By : Jimmy Chen
Block Diagram of Test Setup:
Result:
Please see the attached test data.
Harmonics & Flicker
Analyzer
+
Power Source
( PF 555 )
EUT
Support Units
Power cord
0.8m
Report Number: 02E0683-E
December 5, 2002
Page 23
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 24
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 25
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 26
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 27
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 28
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 29
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 30
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 31
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 32
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 33
Rev. 00
SECTION 3 IEC 61000-4-2 (ELECTROSTATIC DISCHARGE)
ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST
Port : Enclosure
Basic Standard : IEC 61000-4-2
Requirements : ±8 kV (Air Discharge)
±4kV (Contact Discharge)
±4kV (Indirect Discharge)
Performance Criteria : B ( Standard require )
Temperature/Humidity : 190C /58%
Pressure : 1015 mbar
Test By : Jimmy Chen
Block Diagram of Test Setup:
Ground Reference Plane
Wooden Table
Support units EUT HCP
>1m
0.8m
VCP
Report Number: 02E0683-E
December 5, 2002
Page 34
Rev. 00
Test Procedure:
1. The EUT was located 0.1 m minimum from all side of the HCP.
2. The indirect support units were located 1 m minimum away from the EUT, but direct support unit
was/were located at same location as EUT on the HCP and keep at a distance of 10 cm with EUT.
3. A communication test program was loaded and executed in Windows mode.
4. PC sent transmit data to remote side via EUT.
5. As per the requirement of EN 55024; applying direct contact discharge at the sides other than front
of EUT at minimum 50 discharges (25 positive and 25 negative) if applicable, can’t be applied
direct contact discharge side of EUT then the indirect discharge shall be applied. One of the test
points shall be subjected to at least 50 indirect discharge (contact) to the front edge of horizontal
coupling plane.
6. Other parts of EUT where it is not possible to perform contact discharge then selecting appropriate
points of EUT for air discharge, a minimum of 10 single air discharges shall be applied.
7. The application of ESD to the contact of open connectors is not required.
8. Putting a mark on EUT to show tested points. The following test condition was followed during the
tests.
Note: As per IEC 61000-4-2:2001, with two 470k bleed resistors cable is connected between the EUT
and HCP during the test applicable for power ungrounded or battery operating unit only.
The electrostatic discharges were applied as follows:
Amount of
Discharges Voltage Coupling Result (Pass/Fail)
Mini 25 /Point ±4kV Contact Discharge Pass
Mini 25 /Point ±4kV Indirect Discharge HCP (Front) Pass
Mini 25 /Point ±4kV Indirect Discharge VCP (Back) Pass
Mini 25 /Point ±4kV Indirect Discharge VCP (Left) Pass
Mini 25 /Point ±4kV Indirect Discharge VCP (Right) Pass
Mini 10 /Point ±8kV Air Discharge Pass
** The tested points to EUT, please refer to attached page.
(Blue arrow mark for contact discharge, red arrow mark for air discharge.)
Performance & Result:
Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
V Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or
can be restored by the operation of controls.
V PASS FAILED
Observation: No any function degraded during the tests.
Report Number: 02E0683-E
December 5, 2002
Page 35
Rev. 00
The Tested Points of EUT
(Photo 1 of 6)
(Photo 2 of 6)
Report Number: 02E0683-E
December 5, 2002
Page 36
Rev. 00
(Photo 3 of 6)
(Photo 4 of 6)
Report Number: 02E0683-E
December 5, 2002
Page 37
Rev. 00
(Photo 5 of 6)
(Photo 6 of 6)
Report Number: 02E0683-E
December 5, 2002
Page 38
Rev. 00
SECTION 4 IEC 61000-4-3 (RADIATED ELECTROMAGNETIC FIELD )
RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST
Port : Enclosure
Basic Standard : IEC 61000-4-3
Requirements : 3 V/m / with 80% AM. 1kHz Modulation
Performance Criteria : A (Standard require)
Tester : Jimmy Chen
Temperature : 23
Humidity : 72%
Pressure : 1015 mbar
Note : The EUT not have acoustic interfaces, the annex A of EN 55024
should not be applied.
Block Diagram of Test Setup:
Power Amp Signal
Generator
EUT Monitoring by
using a camera
0.8m
Control Room
7x3x3 Chamber
EUT &
Support
PC Controller to control
S.G. & PA as well as
forward power
3m
1.5m
Report Number: 02E0683-E
December 5, 2002
Page 39
Rev. 00
Test Procedure:
1. The EUT and support units were located at the edge of supporting table keep 3 meter away from
transmitting antenna, it just the calibrated square area of field uniformity.
2. Adjusting the cables to be exposed to the electromagnetic filed as possible.
3. Performing a Radiated Emission Scan in range of 30 to 1000 MHz prior to do RS test and records
the more higher emission frequencies for the reference of RS test, due to antenna effectiveness.
4. Adjusting the monitoring camera to monitor the “H” message as clear as possible.
5. Setting the testing parameters of RS test software per IEC 61000-4-3.
6. Referring to the tested data of step 3 to performing the RS test from 80 to 1000 MHz.
7. Recording the test result in following table.
8. Changing the EUT to the other side and repeat step 3 to 6, until 4 sides of EUT were verified.
IEC 61000-4-3 Final test conditions:
Test level : 3V/m
Steps : 1 % of fundamental
Dwell Time : 3 sec
Range (MHz) Field Modulation Polarity Position (°) Result (Pass/Fail)
80-1000 3V Yes H Front Pass
80-1000 3V Yes V Front Pass
80-1000 3V Yes H Right Pass
80-1000 3V Yes V Right Pass
80-1000 3V Yes H Back Pass
80-1000 3V Yes V Back Pass
80-1000 3V Yes H Left Pass
80-1000 3V Yes V Left Pass
Report Number: 02E0683-E
December 5, 2002
Page 40
Rev. 00
Performance & Result:
V Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or
can be restored by the operation of controls.
V PASS FAILED
Observation: No any function degraded during the tests.
Report Number: 02E0683-E
December 5, 2002
Page 41
Rev. 00
SECTION 5 IEC 61000-4-4 (FAST TRANSIENTS/BURST)
FAST TRANSIENTS/BURST IMMUNITY TEST
Port : On Power Lines
Basic Standard : IEC 61000-4-4
Requirements : ±1kV for Power Supply Lines
Performance Criteria : B (Standard require)
Temperature : 210C
Humidity : 58%
Pressure : 1015 mbar
Test By : Jimmy Chen
Block Diagram of Test Setup:
Controller Computer
EFT/Burst/Surge
Generator
EUT
Support
Units
AC
80cm Non-Conductive Table
Line
Report Number: 02E0683-E
December 5, 2002
Page 42
Rev. 00
Test Procedure:
1. The EUT and support units were located on a wooden table 0.8 m away from ground reference
plane.
2. A 1.0 meter long power cord was attached to EUT during the test.
3. The length of communication cable between communication port and clamp was keeping within 1
meter.
4. A test program was loaded and executed in Windows mode.
5. The data was display on the monitor and filling the screens.
6. The test program exercised related support units sequentially.
7. Repeating step 3 to 6 through the test.
8. Recording the test result as shown in following table.
Test conditions:
Impulse Frequency: 5kHz
Tr/Th: 5/50ns
Burst Duration: 15ms
Burst Period: 300mS
Inject Line Voltage kV Inject Method Result (Pass/Fail)
L1 +/- 1 Direct Pass
N +/- 1 Direct Pass
PE +/- 1 Direct Pass
L1+N +/- 1 Direct Pass
L1+PE +/- 1 Direct Pass
N+PE +/- 1 Direct Pass
L1+N+PE +/- 1 Direct Pass
Performance & Result:
V Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or
can be restored by the operation of controls.
V PASS FAILED
Observation: No any function degraded during the tests.
Report Number: 02E0683-E
December 5, 2002
Page 43
Rev. 00
SECTION 6 IEC 61000-4-5 ( SURGE IMMUNITY )
SURGE IMMUNITY TEST
Port : Power Cord
Basic Standard : IEC 61000-4-5
Requirements : ±1kV (Line to Line of Power Port)
±2kV (Line to Earth of Power Port)
Performance Criteria : B (Standard require)
Temperature : 210C
Humidity : 58%
Pressure : 1015 mbar
Test By : Jimmy Chen
Block Diagram of Test Setup:
Surge Immunity
Test
Controller Computer
EUT & Support
Units
80 mm
To AC
Source
Report Number: 02E0683-E
December 5, 2002
Page 44
Rev. 00
Test Procedure:
1. The EUT and support units were located on a wooden table 0.8 m away from ground floor.
2. A test program was loaded and executed in Windows mode.
3. The data was display on the monitor and filling the screens.
4. The test program exercised related support units sequentially.
5. Repeating step 3 to 4 through the test.
6. Recording the test result as shown in following table.
Test conditions:
Voltage Waveform : 1.2/50 µs
Current Waveform : 8/20 µs
Polarity : Positive/Negative
Phase angle : 00, 900, 2700
Number of Test : 5
Coupling Line Voltage (kV) Polarity Coupling Method Result (Pass/Fail)
L1-L2 L1-PE L2-PE 1 Positive Capacitive Pass
L1-L2 L1-PE L2-PE 1 Negative Capacitive Pass
L1-PEL2-PE 2 Positive Capacitive Pass
L1-PEL2-PE 2 Negative Capacitive Pass
Performance & Result:
V Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can
be restored by the operation of controls.
V PASS FAILED
Observation: No any function degraded during the tests.
Report Number: 02E0683-E
December 5, 2002
Page 45
Rev. 00
SECTION 7 IEC 61000-4-6 (CONDUCTED DISTRBANCE/INDUCED BY
RADIO-FREQUENCY FIELD)
CONDUCTED DISTURBANCE, INDUCED BY RADIO-FREQUENCY FIELDS
Port : AC Port
Basic Standard : IEC 61000-4-6
Requirements : 3V with 80% AM. Modulation
Injection Method : CDN-M3
Performance Criteria : A (Standard require)
Temperature : 240C
Humidity : 72%
Pressure : 1015 mbar
Test By : Jimmy Chen
Block Diagram of Test Setup:
CDN
EUT and
Support units Power
Amplifier
PC
Controller
Ground Reference Plane
10 cm isolation
supporter
0.1m< L <0.3m
Report Number: 02E0683-E
December 5, 2002
Page 46
Rev. 00
Top view:
Test Procedure:
1. The EUT and support units were located at a ground reference plane with the interposition of a 0.1
m thickness insulating support and the CDN was located on GRP directly.
2. Transmit data message were displayed on screen of Monitor.
3. Adjusting the monitoring camera to monitor the transmit data message as clear as possible.
4. Setting the testing parameters of CS test software per IEC 61000-4-6.
5. Recording the test result in following table.
Power
Amplifier
PC
Controller
EM-Cla
mp
EUT &
Support
Units
Support
Units
Ground Reference Plane
3 - 5 cm isolation supporter
10 cm isolation supporter
Report Number: 02E0683-E
December 5, 2002
Page 47
Rev. 00
Test conditions:
Frequency Range : 0.15MHz-80MHz
Frequency Step : 1% of fundamental
Dwell Time : 3 sec
Range (MHz) Field Modulation Result (Pass/Fail)
0.15-80 3V Yes Pass
Performance & Result:
V Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self-recoverable or
can be restored by the operation of controls.
V PASS FAILED
Observation: No any function degraded during the tests.
Report Number: 02E0683-E
December 5, 2002
Page 48
Rev. 00
SECTION 8 IEC 61000-4-8 (POWER FREQUENCY MAGNETIC FIELD
IMMUNITY TEST)
POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
Port : Enclosure
Basic Standard : IEC 61000-4-8
Requirements : 1 A/m
Performance Criteria : A (Standard Required)
Temperature : N/A
Humidity : N/A
Pressure : N/A
Test By : N/A
Block Diagram of Test Setup:
EUT
Signal
Generator
To
Earth Ground
To
Earth Ground
Induction
Coil
10mm thick
Insulation Support
of EUT
Report Number: 02E0683-E
December 5, 2002
Page 49
Rev. 00
Test Procedure:
1. The EUT and support units were located on Ground Reference Plane with the interposition of a
0.1 m thickness insulation support.
2. Putting the induction coil on horizontal direction.( X direction )
3. A test program was loaded and executed in Windows mode.
4. The data was sent to the screen of EUT and filling the screen with upper case of “H” patterns.
5. The test program exercised related support units sequentially.
6. Repeating step 3 to 5 through the test.
7. Recording the test result as shown in following table.
8. Rotating the induction coil by 900 ( Y direction ) then repeat step 3 to 7.
9. Rotating the induction coil by 900 again ( Z direction ) then repeat step 3 to 7.
*. Test conditions:
Field Strength: 1A/m
Power Freq.: 50Hz
Orientation: X, Y, Z
Orientation Field Result (Pass/Fail) Remark
**Note: Not applicable, because no any component can be influenced by power magnetic fields.
Performance & Result:
Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can
be restored by the operation of controls.
PASS FAILED
Observation: N/A (EUT Without any magnetic component)
Report Number: 02E0683-E
December 5, 2002
Page 50
Rev. 00
SECTION 9 IEC 61000-4-11
(VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS )
VOLTAGE DIPS / SHORT INTERRUPTIONS
Port : AC mains
Basic Standard : IEC 61000-4-11 (1994)
Requirement : PHASE ANGLE 0, 45, 90, 135, 180, 225, 270, 315 degrees
Test Level
% UT Reduction
(%) Duration
( periods ) Performance
Criteria
<5 >95 0.5 B
Voltage
Dips 70 30 25 C
Test Level
% UT Reduction
(%) Duration
( periods ) Performance
Criteria
Voltage
Interceptions <5 >95 250 C
Test Interval : Min. 10 sec.
Temperature : 210C
Humidity : 58%
Pressure : 1015 mbar
Test By : Jimmy Chen
Block Diagram of Test Setup:
Dips/Interruption and
Variations Simulator
Controller Computer
EUT
&
Support Units
80 mm
To AC
Source
Report Number: 02E0683-E
December 5, 2002
Page 51
Rev. 00
Test Procedure:
1. The EUT and support units were located on a wooden table, 0.8 m away from ground floor.
2. A test program was loaded and executed in Windows mode.
3. The data was displayed on the monitor and filling the screens.
4. The test program exercised related support units sequentially.
5. Setting the parameter of test and then Perform the test software of test simulator.
6. Conditions changes to occur at 0 degree crossover point of the voltage waveform.
7. Repeating step 3 to 4 through the test.
8. Recording the test result in the test record form.
Test conditions:
The duration with a sequence of three dips/interruptions with interval of 10 s minimum
( Between each test event )
Voltage Dips:
Test Level
% UT Reduction
(%) Duration
( periods) Observation Meet Performance
Criteria
0 100 0.5 Normal A
70 30 25 Normal A
Voltage Interruptions:
Test Level
% UT Reduction
(%) Duration
( periods) Observation Meet Performance
Criteria
0 100 250 Host PC shut down, but
EUT can be auto
recovered after Host PC
restart.
C
Performance & Result:
Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or
can be restored by the operation of controls.
V PASS FAILED
Report Number: 02E0683-E
December 5, 2002
Page 52
Rev. 00
APPENDIX 1
PHOTOGRAPHS OF TEST SETUP
Report Number: 02E0683-E
December 5, 2002
Page 53
Rev. 00
LINE CONDUCTED EMISSION TEST (EN 55022)
Report Number: 02E0683-E
December 5, 2002
Page 54
Rev. 00
RADIATED EMISSION TEST (EN 55022)
Report Number: 02E0683-E
December 5, 2002
Page 55
Rev. 00
POWER HARMONIC & VOLTAGE FLUCTUATION / FLICKER TEST
(EN 61000-3-2, EN 61000-3-3)
Report Number: 02E0683-E
December 5, 2002
Page 56
Rev. 00
ELECTROSTATIC DISCHARGE TEST (IEC 61000-4-2)
Report Number: 02E0683-E
December 5, 2002
Page 57
Rev. 00
RADIATED ELECTROMAGNETIC FIELD (IEC 61000-4-3)
Front View
Back View
Report Number: 02E0683-E
December 5, 2002
Page 58
Rev. 00
Left View
Right View
Report Number: 02E0683-E
December 5, 2002
Page 59
Rev. 00
FAST TRANSIENTS/BURST TEST & SURGE IMMUNITY TEST
(IEC 61000-4-4/5)
Report Number: 02E0683-E
December 5, 2002
Page 60
Rev. 00
CONDUCTED DISTURBANCE, INDUCED BY RADIO-FREQUENCY FIELDS
TEST (IEC 61000-4-6)
Report Number: 02E0683-E
December 5, 2002
Page 61
Rev. 00
VOLTAGE DIPS / INTERRUPTION TEST (IEC 61000-4-11)
Report Number: 02E0683-E
December 5, 2002
Page 62
Rev. 00
APPENDIX 2
PHOTOGRAPHS OF EUT
Report Number: 02E0683-E
December 5, 2002
Page 63
Rev. 00
Report Number: 02E0683-E
December 5, 2002
Page 64
Rev. 00
APPENDIX 3
CONDUCTED EMISSION PLOT
RADIATED EMISSION DATA
No. 199, Chung Sheng Road,
Hsin Tien City, Taipei,
Taiwan, R.O.C.
Tel:02-2217-0894 Fax:02-2217-1254
Data#: 18 File#: 0683c.emi Date: 2002-12-04 Time: 20:08:28
Trace: 7 8 Ref Trace:
Condition: LINE
Report No. : 02E0683
Test Engr. : JIMMY CHEN
Company : TAIWAN TAI-HAO ENTERPRISE CO., LTD.
EUT : F21 XP SERIES
Test Config : EUT / ALL PERIPHERALS
Type of Test: EN55022 CLASS B
Mode of Op. : NORMAL MODE
Page: 1
Read Limit Over
Freq Level Factor Level Line Limit Remark
_________ ______ ______ ______ ______ ______ ______
MHz dBuV dB dBuV dBuV dB
1 0.158 46.34 0.03 46.37 65.56 -19.19 Peak
2 0.258 46.72 0.04 46.76 61.51 -14.75 Peak
3 0.410 40.76 0.06 40.82 57.64 -16.82 Peak
4 0.555 40.80 0.07 40.87 56.00 -15.13 Peak
5 0.994 41.13 0.10 41.23 56.00 -14.77 Peak
6 6.488 38.42 0.29 38.71 60.00 -21.29 Peak
No. 199, Chung Sheng Road,
Hsin Tien City, Taipei,
Taiwan, R.O.C.
Tel:02-2217-0894 Fax:02-2217-1254
Data#: 17 File#: 0683c.emi Date: 2002-12-04 Time: 20:07:59
Trace: 15 16 Ref Trace:
Condition: NEUTRAL
Report No. : 02E0683
Test Engr. : JIMMY CHEN
Company : TAIWAN TAI-HAO ENTERPRISE CO., LTD.
EUT : F21 XP SERIES
Test Config : EUT / ALL PERIPHERALS
Type of Test: EN55022 CLASS B
Mode of Op. : NORMAL MODE
Page: 1
Read Limit Over
Freq Level Factor Level Line Limit Remark
_________ ______ ______ ______ ______ ______ ______
MHz dBuV dB dBuV dBuV dB
1 0.158 45.66 0.03 45.69 65.56 -19.87 Peak
2 0.183 46.74 0.03 46.77 64.33 -17.56 Peak
3 0.258 50.93 0.04 50.97 61.51 -10.54 Peak
4 0.410 41.92 0.06 41.98 57.64 -15.66 Peak
5 0.555 42.24 0.07 42.31 56.00 -13.69 Peak
6 0.994 42.01 0.10 42.11 56.00 -13.89 Peak
No. 199, Chung Sheng Road,
Hsin Tien City, Taipei,
Taiwan, R.O.C.
Tel:02-2217-0894 Fax:02-2217-1254
Data#: 1File#: 0683d.emi Date: 2002-12-04 Time: 22:30:58
D-Site
Condition: VERTICAL / 10m
Report No. : 02E0683
Test Engr. : JIMMY CHEN
Company : TAIWAN TAI-HAO ENTERPRISE CO., LTD.
EUT : F21 XP SERIES
Test Config : EUT / ALL PERIPHERALS
Type of Test: EN55022 CLASS B
Mode of Op. : NORMAL MODE
Page: 1
Read Limit Over
Freq Level Factor Level Line Limit Remark
_________ ______ ______ ______ ______ ______ ______
MHz dBuV dB dBuV/m dBuV/m dB
1 39.180 34.45 -9.65 24.80 30.00 -5.20 Peak
2 48.030 34.20 -8.09 26.12 30.00 -3.89 Peak
3 60.080 34.29 -10.71 23.58 30.00 -6.42 Peak
4 74.530 34.71 -12.59 22.12 30.00 -7.88 Peak
5 120.050 32.88 -9.01 23.87 30.00 -6.13 Peak
6 180.350 34.32 -8.19 26.13 30.00 -3.87 Peak
7 242.800 35.40 -8.56 26.84 37.00 -10.16 Peak
8 355.450 30.16 -2.82 27.34 37.00 -9.66 Peak
9 498.880 31.19 0.89 32.08 37.00 -4.92 Peak
No. 199, Chung Sheng Road,
Hsin Tien City, Taipei,
Taiwan, R.O.C.
Tel:02-2217-0894 Fax:02-2217-1254
Data#: 2File#: 0683d.emi Date: 2002-12-04 Time: 22:41:13
D-Site
Condition: HORIZONTAL / 10m
Report No. : 02E0683
Test Engr. : JIMMY CHEN
Company : TAIWAN TAI-HAO ENTERPRISE CO., LTD.
EUT : F21 XP SERIES
Test Config : EUT / ALL PERIPHERALS
Type of Test: EN55022 CLASS B
Mode of Op. : NORMAL MODE
Page: 1
Read Limit Over
Freq Level Factor Level Line Limit Remark
_________ ______ ______ ______ ______ ______ ______
MHz dBuV dB dBuV/m dBuV/m dB
1 40.400 32.15 -9.50 22.65 30.00 -7.35 Peak
2 59.800 31.82 -10.53 21.29 30.00 -8.71 Peak
3 73.730 31.12 -12.59 18.53 30.00 -11.47 Peak
4 119.950 32.44 -9.01 23.43 30.00 -6.57 Peak
5 179.930 31.80 -8.12 23.68 30.00 -6.32 Peak
6 240.000 31.78 -8.58 23.20 37.00 -13.80 Peak
7 355.330 31.78 -2.82 28.96 37.00 -8.04 Peak
8 500.350 31.43 0.90 32.33 37.00 -4.67 Peak