02E0683 E_太豪 KEYBOARD_ 171588 & 171595 CE Certification Tai Hao

171588 & 171595 Ce Certification Tai Hao 171588_&_171595_CE_certification--Tai_hao 171588_&_171595_CE_certification--Tai_hao CertsReports 171588 ProductFiles assets.mhint

2016-04-05

: Pdf 171588 & 171595 Ce Certification Tai Hao 171588_&_171595_CE_certification--Tai_hao CertsReports 171595 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 68

Download02E0683-E_太豪 KEYBOARD_  171588 & 171595 CE Certification--Tai Hao
Open PDF In BrowserView PDF
Report Number: 02E0683-E
December 5, 2002

EMC COMPLIANCE TEST REPORT
for
KEYBOARD
Trade Name
: Tai-Hao; Clicker
Model Number : F21 XP SERIES
F21XP2 / F21XP1 / F21XP3 / F21XP5 / F21XP10 / F21XP7
Serial Number : N/A
Report Number : 02E0683-E
Date
: December 5, 2002
Regulations
: See below
Standards
Results (Pass/Fail)
EN 55022: 1998
PASS
EN 61000-3-2: 1995+A1: 1998+A2: 1998+A14: 2000 PASS
EN 61000-3-3: 1995
PASS
EN 55024: 1998
PASS
- IEC 61000-4-2: 1995 +A2: 2001
PASS
- IEC 61000-4-3: 1995
PASS
- IEC 61000-4-4: 1995
PASS
- IEC 61000-4-5: 1995
PASS
- IEC 61000-4-6: 1996
PASS
- IEC 61000-4-8: 1993
N/A
- IEC 61000-4-11: 1994
PASS
Prepared for:

TAIWAN TAI-HAO ENTERPRISE CO., LTD.
6F-5, NO. 155, KEELUNG RD., SEC. 1,
TAIPEI TAIWAN
Prepared by:

C&C LABORATORY CO., LTD.
#B1, 1st Fl., Universal Center,
No. 183, Sec. 1, Tatung Rd., Hsi Chin,
Taipei Hsien, Taiwan, R.O.C.
TEL: (02)86422071
FAX: (02)86422256
This report shall not be reproduced, except in full, without the written approval of
C&C Laboratory Co., Ltd.

Page 1 of 66
Rev. 00

Report Number: 02E0683-E
December 5, 2002

EC-Declaration of Conformity
For the following equipment:
KEYBOARD
( Product Name )
F21 XP SERIES
F21XP2 / F21XP1 / F21XP3 / F21XP5 / F21XP10 / F21XP7
( Model Designation / Trade name )
TAIWAN TAI-HAO ENTERPRISE CO., LTD.
( Manufacturer Name )
6F-5, NO. 155, KEELUNG RD., SEC. 1, TAIPEI TAIWAN
(Manufacturer Address)
is herewith confirmed to comply with the requirements set out in the Council Directive on the
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive
(89/336/EEC, Amended by 92/31/EEC, 93/68/EEC & 98/13/EC), For the evaluation regarding the
Electromagnetic Compatibility (89/336/EEC, Amended by 92/31/EEC & 93/68/EEC & 98/13/EC ) the
following standards are applied:
V EN 55022: 1998
V EN 61000-3-2: 1995+A1: 1998+A2: 1998+A14: 2000
V EN 61000-3-3: 1995
V EN55024: 1998
IEC 61000-4-2: 1995 +A2: 2001, IEC 61000-4-3: 1995, IEC 61000-4-4: 1995
IEC 61000-4-5: 1995, IEC 61000-4-6: 1996, IEC 61000-4-11: 1994
The following manufacturer / importer or authorized representative established within the EUT is
responsible for this declaration:

( Company Name )
( Company Address )

Person responsible for making this declaration:
( Name, Surname )
( Position / Title )
( Place )

( Date )

( Legal Signature )
Page 2
Rev. 00

Report Number: 02E0683-E
December 5, 2002

TABLE OF CONTENTS
DESCRIPTION

PAGE

VERIFICATION OF COMPLIANCE

5

GENERAL INFORMATION

6

SYSTEM DESCRIPTION

7

PRODUCT INFORMATION

8

SUPPORT EQUIPMENT

9

TEST FACILITY

10

TEST EQUIPMENT
SECTION 1 EN 55022(LINE CONDUCTED & RADIATED
EMISSION)

11
14

MEASUREMENT PROCEDURE & LIMIT (LINE CONDUCTED
EMISSION TEST)
MEASUREMENT PROCEDURE & LIMIT (COMMON MODE
CONDUCTED EMISSION MEASUREMENT)
MEASUREMENT PROCEDURE & LIMIT (RADIATED EMISSION
TEST)

14

BLOCK DIAGRAM OF TEST SETUP

19

SUMMARY DATA
SECTION 2 EN61000-3-2 & EN 61000-3-3 (POWER HARMONICS

20

16
17

22

& VOLTAGE FLUCTUATION/FLICKER)
BLOCK DIAGRAM OF TEST SETUP

22

RESULT

22

SECTION 3 IEC 61000-4-2 (ELECTROSTATIC DISCHARGE)

33

BLOCK DIAGRAM OF TEST SETUP

33

TEST PROCEDURE

34

PERFORMANCE & RESULT

34

SECTION 4 IEC 61000-4-3 (RADIATED ELECTROM

38

AGNETIC FIELD)
BLOCK DIAGRAM OF TEST SETUP

38

TEST PROCEDURE

39

PERFORMANCE & RESULT

40

Page 3
Rev. 00

Report Number: 02E0683-E
December 5, 2002

DESCRIPTION
SECTION 5

IEC 61000-4-4 (FAST TRANSIENTS/BURST)

PAGE
41

BLOCK DIAGRAM OF TEST SETUP

41

TEST PROCEDURE

42

PERFORMANCE & RESULT
SECTION 6 IEC 61000-4-5 (SURGE IMMUNITY)

42

BLOCK DIAGRAM OF TEST SETUP

43

TEST PROCEDURE

44

PERFORMANCE & RESULT
SECTION 7 IEC 61000-4-6 (CONDUCTED DISTURBANCE,
INDUCED BY RADIO-FREQUENCY FIELDS)

44

BLOCK DIAGRAM OF TEST SETUP

45

TEST PROCEDURE

47

PERFORMANCE & RESULT
SECTION 8 IEC 61000-4-8 (Power Frequency Magnetic Field))

47

BLOCK DIAGRAM OF TEST SETUP

48

TEST PROCEDURE

49

PERFORMANCE & RESULT
SECTION 9 IEC 61000-4-11 (VOLTAGE DIP/INTERRUPTION)

49

BLOCK DIAGRAM OF TEST SETUP

50

TEST PROCEDURE

51

PERFORMANCE & RESULT

51

APPENDIX 1 PHOTOGRAPHS OF TEST SETUP
EN 55022 TEST
EN 61000-3-2 TEST
EN 61000-3-3 TEST
IEC 61000-4-2 TEST
IEC 61000-4-3 TEST
IEC 61000-4-4 TEST
IEC 61000-4-5 TEST
IEC 61000-4-6 TEST
IEC 61000-4-11 TEST

52

APPENDIX 2 PHOTOGRAPHS OF EUT

62

APPENDIX 3 CONDUCTED EMISSION PLOT & RADIATED

64

43

45

48

50

EMISSION DATA

Page 4
Rev. 00

Report Number: 02E0683-E
December 5, 2002

VERIFICATION OF COMPLIANCE
Equipment Under Test:

KEYBOARD

Trade Name:

Tai-Hao; Clicker

Model Number:

F21 XP SERIES
F21XP2 / F21XP1 / F21XP3 / F21XP5 / F21XP10 / F21XP7
N/A

Serial Number:
Applicant:

TAIWAN TAI-HAO ENTERPRISE CO., LTD.
6F-5, NO. 155, KEELUNG RD., SEC. 1,
TAIPEI TAIWAN

Manufacturer:

TAIWAN TAI-HAO ENTERPRISE CO., LTD.
6F-5, NO. 155, KEELUNG RD., SEC. 1,
TAIPEI TAIWAN
EMC Directive 89/336/EEC for CE Marking

Type of Test:
Technical Standards:

File Number:

EN 55022: 1998
EN 61000-3-2: 1995+A1: 1998+A2: 1998+A14: 2000
EN 61000-3-3: 1995
EN 55024: 1998
(IEC 61000-4-2: 1995 +A2: 2001, IEC 61000-4-3: 1995
IEC 61000-4-4: 1995, IEC 61000-4-5: 1995
IEC 61000-4-6: 1996, IEC 61000-4-11: 1994)
02E0683-E

Date of test:

December 4, 2002

Deviation:

None

Condition of Test Sample: Normal
Final Result:

Pass

Worst data:

See below
Test Item
Freq.
Measured data
Margin (MìC)
Remark
Radiated Emission
180.350 (MHz) 26.13 (dBìV/m) -3.87dB (± 3.3498 dB)
Vertical
Conducted Emission 0.258 (MHz)
50.97 (dBìV)
-10.54dB (± 2.8108 dB) Neutral
l The negative sign in Margin cell means under the specific limit.
l This test result traceable to national or international standards
The above equipment was tested by C&C Laboratory Co., Ltd. for compliance with the requirements
set forth in EMC Directive 89/336/EEC and the Technical Standards mentioned above. This said
equipment in the configuration described in this report shows the maximum emission levels emanating
from equipment and the level of the immunity endurance of the equipment are within the compliance
requirements.
The test results of this report relate only to the tested sample identified in this report.

Approved by Authorized Signatory:
James Chan / Manager
Page 5
Rev. 00

Report Number: 02E0683-E
December 5, 2002

GENERAL INFORMATION

Applicant:

TAIWAN TAI-HAO ENTERPRISE CO., LTD.
6F-5, NO. 155, KEELUNG RD., SEC. 1,
TAIPEI TAIWAN

Contact Person:

Kelly Wang

Manufacturer:

TAIWAN TAI-HAO ENTERPRISE CO., LTD.
6F-5, NO. 155, KEELUNG RD., SEC. 1,
TAIPEI TAIWAN

File Number:

02E0683-E

Date of Test:

December 4, 2002

Equipment Under Test:

KEYBOARD

Trade Name:

Tai-Hao; Clicker

Model Number:

F21 XP SERIES
F21XP2 / F21XP1 / F21XP3 / F21XP5 / F21XP10 / F21XP7

Serial Number:

N/A

Type of Test:

EMC Directive 89/336/EEC for CE Marking

Technical Standards:

EN 55022: 1998
EN 61000-3-2: 1995+A1: 1998+A2: 1998+A14: 2000
EN 61000-3-3: 1995
EN 55024: 1998
(IEC 61000-4-2: 1995 +A2: 2001, IEC 61000-4-3: 1995
IEC 61000-4-4: 1995, IEC 61000-4-5: 1995
IEC 61000-4-6: 1996, IEC 61000-4-11: 1994)

Frequency Range
(EN 55022):

150kHz to 30MHz for Line Conducted Test
30MHz to 1000MHz for Radiated Emission Test

Test Site

C&C LABORATORY CO., LTD.
No. 199, Chung Sheng Road, Hsin Tien City, Taipei
Taiwan, R. O. C.

Page 6
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SYSTEM DESCRIPTION
EUT Test Procedure:
1. Windows 98 Boots System.
2. Run Emctest.exe & Emitest.exe To Activate All Peripherals And Display “H” Pattern On Monitor
Screen.

Page 7
Rev. 00

Report Number: 02E0683-E
December 5, 2002

PRODUCT INFORMATION
Housing Type:

Plastic

EUT Power Rating:

DC 5V from Host PC

AC power during Test:

230VAC, 50Hz to Host PC Power Supply

Power Supply Manufacturer:

Line-on

Power Supply Model Number:

PS-5141-6G

AC Power Cord Type:

Unshielded, 1.8m (Detachable)

EUT I/O Cable Type:

Unshielded, 1.3m (Detachable, with a core)

OSC/Clock Frequency:

N/A

Model Differences:
Model Name

Tested
(Checked)

Differences

Original

F21 XP SERIES
F21XP2 / F21XP1 /
Additional F21XP3 / F21XP5 /
F21XP10 / F21XP7

COLOR DIFFERENCE FOR KB
KEY CAPS&CASING

I/O Port of EUT:
I/O PORT TYPES
1). PS/2 KEYBOARD PORT

Q’TY

TESTED WITH

1

1

Note: N/A

Page 8
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SUPPORT EQUIPMENT
Peripherals Devices:
No Equipment

Model

Serial

FCC/ BSMI

#

#

ID

Trade Name

1.

PS/2
Mouse

2.

Modem

3.

Host PC

EVOD300

6K1BKF83F2ZD

DoC
COMPAQ
BSMI ID:3892Q094

4.

Monitor

RB17NS

N/A

DoC
SAMSUNG
BSMI ID:3902B332

5.

Printer

EPSONSTYLU
EW4E126644
SC20SX

DZL211029
LOGITECH
BSMI ID:4862A011
L0063CG2D0071
TOP5JEG4033MKO
5RJTAI-35500-M 5-E
90
SOLUTION
M-S34

LZED1303050

BSMI ID:3902E004 EPSON

Data
Cable
Shielded,
1.9m
Shielded,
0.8 m
Unshielded,
1.3m
with a core
Shielded,
1.8m
with two cores
Shielded,
1.8 m

Power
Cord
N/A
Unshielded,
1.8m
Unshielded,
1.8m
Unshielded,
1.8m
with a core
Unshielded,
1.8m

Note: All the above equipment/cables were placed in worse case positions to maximize emission
signals.
Grounding: Grounding was in accordance with the manufacturer’s requirements and conditions
for the intended use.

Page 9
Rev. 00

Report Number: 02E0683-E
December 5, 2002

TEST FACILITY
Location:

No. 199, Chung Sheng Road, Hsin Tien City,
Taipei, Taiwan, R. O. C.

Description:

There are two 3/10m open area test sites and one line conducted lab for
final test.
The Open Area Test Sites and the Line Conducted labs are constructed
and calibrated to meet the FCC requirements in documents ANSI C63.4:
1992 and CISPR 22/EN 55022 requirements.

Site Filing:

A site description is on file wit h the Federal Communications
Commission, 7435 Oakland Mills Road, Columbia, MD 21046.
Registration also was made with Voluntary Control Council for
Interference (VCCI). Registration No. R-1434/ C-1511

Site Accreditation:

Accredited by A2LA (Certificate #: 824.01) for EMC.
Also accredited by BSMI for the product category of Information
Technology Equipment.

Instrument Tolerance:

All measuring equipment is in accord with ANSI C63.4 and CISPR 22
requirements that meet industry regulatory agency and accreditation
agency requirement.

Ground Plane:
Two conductive reference ground planes were used during the Line Conducted
Emission, one in vertical and the other in horizontal. The dimensions of these ground planes are as
below. The vertical ground plane was placed distancing 40 cm to the rear of the wooden test table on
where the EUT and the support equipment were placed during test. The horizontal ground plane
projected 50 cm beyond the footprint of the EUT system and distanced 80 cm to the wooden test table.
For Radiated Emission Test, one horizontal conductive ground plane extended at least 1m beyond the
periphery of the EUT and the largest measuring antenna, and covered the entire area between the EUT
and the antenna. It has no holes or gaps having longitudinal dimensions larger than one-tenth of a
wavelength at the highest frequency of measurement up to 1GHz.

Page 10
Rev. 00

Report Number: 02E0683-E
December 5, 2002

TEST EQUIPMENT LIST (EMISSION)
Instrumentation: The following list contains equipment used at C & C Laboratory Co., Ltd. for
testing. The equipment conforms to the CISPR 16-1 / ANSI C63.2-1988 Specifications for
Electromagnetic Interference and Field Strength Instrumentation from 9kHz to 1.0 / 2.0 GHz.
Equipment used during the tests:
Open Area Test Site:
EQUIPMENT
TYPE
EMC
ANALYZER
AMPLIFIER
ANTENNA
CABLE

#D
MFR

MODEL
NUMBER

SERIAL
NUMBER

LAST
CAL.

CAL.
DUE

HP

8595EM

3412A00104

03/01/02

02/28/03

HP
SCHWARZBECK
BELDEN

8447DB
VULB 9160
9913

1644A02328
3104
N-TYPE08

05/05/02
05/12/02
04/17/02

05/04/03
05/11/03
04/16/03

Conducted Area Test Site: Conducted Room
EQUIPMENT
TYPE

MFR

MODEL
NUMBER

SERIAL
NUMBER

LAST
CAL.

CAL.
DUE

R&S

ESHS20

840455/006

03/16/02

03/15/03

LISN

EMCO

3825/2

1842

01/11/02

01/10/03

LISN(EUT)

EMCO

3825/2

1435

01/16/02

01/15/03

TEST
RECEIVER

The calibrations of the measuring instruments, including any accessories that may effect such
calibration, are checked frequently to assure their accuracy. Adjustments are made and correction
factors applied in accordance with instructions contained in the ma nual for the measuring instrument.

Page 11
Rev. 00

Report Number: 02E0683-E
December 5, 2002

TEST EQUIPMENT LIST
For Power Harmonic & Voltage Fluctuation/Flicker Measurement:
Manufacturer/Type
HP /
Harmonic & Flicker Tester

Model No.

Serial No.

Last Cal.

Cal. Due

6842A

3531A-000142

06/18/2002

06/17/2003

Model No.

Serial No.

Last Cal.

Cal. Due

NSG 432

2029

02/06/2002

02/05/2003

For ESD test:
Manufacturer/Type
Schaffner /
ESD Simulator

For Radiated Electromagnetic Field immunity Measurement:
Manufacturer/Type
R&S / Signal Generator
IFI /
“E” Field sensor/ Light
Modulator Transmitter
IFI / Combination Amplifier

Model No.
SMY 02
EFS-5

Serial No.
DE13751
713-0695

Last Cal.
01/10/2002
06/28/2002

Cal. Due
01/09/2003
06/27/2003

SMX100

2067-1196

IFI / Leveling Pre-Amplifier

LPA-5B

714-0695

EMCO / Biconilog Antenna

3142

9609-1087

No Calibration
Required
No Calibration
Required
No Calibration
Required

No Calibration
Required
No Calibration
Required
No Calibration
Required

Model No.
E421

Serial No.
9502326

Last Cal.
10/01/2002

Cal. Due
09/30/2003

CCL-4

9503290

No Calibration
Required

No Calibration
Required

Model No.
E501

Serial No.
9502324

Last Cal.
10/01/2002

Cal. Due
09/30/2003

CM-TELCD

0104399

No Calibration
Required

No Calibration
Required

CM-I/OCD

0103234

No Calibration
Required

No Calibration
Required

For Fast Transients/Burst test:
Manufacturer/Type
KeyTek Instruments /
EFT Generator
KeyTek Instruments /
Capacitive Clamp

For Surge Immunity test:
Manufacturer/Type
KeyTek Instruments/
Surger Generator
Telecom Lines Coupler
DECOUPLER
KeyTek Instruments
I/O Signal Line
DECOUPLER
KeyTek Instruments

Page 12
Rev. 00

Report Number: 02E0683-E
December 5, 2002

For CS test:
Manufacturer/Type
R&S / Signal Generator
IFI / Combination Amplifier

Model No.
SMY 02
SMX100

Serial No.
DE13751
2067-1196

99122

Last Cal.
01/10/2002
No Calibration
Required
No Calibration
Required
11/02/2002

Cal. Due
01/09/2003
No Calibration
Required
No Calibration
Required
11/01/2003

IFI / Leveling Pre-Amplifier

LPA-5B

714-0695

54

11/02/2002

11/01/2003

02541

No Calibration
Required

No Calibration
Required

Model No.
MAG 100.1

Serial No.
081436-02

CFC-105

810390

932C

2K0900285

Last Cal.
No Calibration
Required
No Calibration
Required
10/24/2002

Cal. Due
No Calibration
Required
No Calibration
Required
10/23/2003

FISCHER /
FCC-801-M3-16A
Power Line Coupling
Decoupling Network
FISCHER /
F-120-9B
Bulk Current Injection Probe
Narda /
769-6
High Power Attenuator

For Power Frequency Magnetic Field test :
Manufacturer/Type
Haefely /
Magic Field Tester
Extech Electronics /
Frequency Converter
CHY/
AC/DC Clamp Meter

For Voltage Dips/Short Interruption and Voltage Variation Immunity test:
Manufacturer/Type
Haefely /
Dips/Inerruption/Variations
Tester
FLUKE /
79 Series Ii Multimeter

Model No.
PLINE 1610

Serial No.
081568-06

Last Cal.
04/25/2002

Cal. Due
04/24/2003

79-II

66400868

07/02/2002

07/01/2003

Page 13
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SECTION 1 EN 55022 (LINE CONDUCTED & RADIATED EMISSION)

MEASUREMENT PROCEDURE
(PRELIMINARY LINE CONDUCTED EMISSION TEST)
1) The equipment was set up as per the test configuration to simulate typical actual usage per the
user’s manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is
used and is placed on the ground plane as per EN 55022 (see Test Facility for the dimensions of
the ground plane used). When the EUT is a floor-standing equipment, it is placed on the
ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground
plane.
2) Support equipment, if needed, was placed as per EN 55022.
3) All I/O cables were positioned to simulate typical actual usage as per EN 55022.
4) The EUT received DC 5V power through Host PC and Line Impedance Stabilization Network
(LISN) which supplied power source of 230VAC/ 50Hz and was grounded to the ground plane.
5) All support equipment received power from a second LISN supplying power of 110VAC/60Hz, if
any.
6) The EUT test program was started. Emissions were measured on each current carrying line of
the EUT using a spectrum analyzer / Receiver connected to the LISN powering the EUT. The
LISN has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were
taken: one with Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load;
the second scan had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer /
Receiver.
7) Analyzer / Receiver scanned from 150kHz to 30MHz for emissions in each of the test modes.
8) During the above scans, the emissions were maximized by cable manipulation.
9) The following test mode were scanned during the preliminary test:
Mode:
1

NORMAL MODE

10) After the preliminary scan, we found the following test mode producing the highest emission
level.
Mode:

1.

Then, the EUT configuration and cable configuration of the above highest emission level were
recorded for reference of final testing.

Page 14
Rev. 00

Report Number: 02E0683-E
December 5, 2002

MEASUREMENT PROCEDURE
(FINAL LINE CONDUCTED EMISSION TEST)
1) EUT and support equipment was set up on the test bench as per step 10 of the preliminary test.
2) A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest
emissions. Emission frequency and amplitude were recorded into a computer in which correction
factors were used to calculate the emission level and compare reading to the applicable limit. If
EUT emission level was less –2dB to the A.V. limit in Q.P. mode, then the emission signal was
re-checked using an A.V. detector.
3) The test data of the worst case condition(s) was reported on the Summary Data page.
Data Sample:
Meter
Freq
Reading
(MHz)
(dBuV)
x.xx
x.xx

C.F.
(dB)
x.xx

Corrected
Reading
(dBuV)
38.38

Limits
(dBuV)
56.00

Margin
(dB)
-17.62

Reading
Type
(P/Q/A)
P

Line
(L1/L2)
L1

C.F.(Correction Factor)=Insertion Loss + Cable Loss
Corrected Reading = Metering Reading + C.F.
Margin=Corrected Reading - Limits
P=Peak Reading
Q=Quasi-peak
A=Average Reading

L1=Hot
L2=Neutral

Comments: N/A
Calculation example:
Margin (dB) = Corrected Reading (dBuV) – Limit (dBuV)

LINE CONDUCTED EMISSION LIMIT (EN 55022)
Frequency
150kHz-500kHz
500kHz-5MHz
5MHz-30MHz

Maximum RF Line Voltage
Q.P.
AVERAGE
66-56dBuV
56-46dBuV
56dBuV
46dBuV
60dBuV
50dBuV

Note: The lower limit shall apply at the transition frequency.

Page 15
Rev. 00

Report Number: 02E0683-E
December 5, 2002

MEASUREMENT PROCEDURE
(COMMON MODE CONDUCTED EMISSION MEASUREMENT)
1) Selecting ISN for unscreened cable or a current probe for screened cable to take measurement.
2) The port of the EUT was connected to the remote side support equipment through the ISN/Current
Probe and communication in normal condition.
3) Making a overall range scan by using the test receiver controlled by controller and record at least
six highest emissions for showing in the test report.
4) Emission frequency and amplitude were recorded into a computer in which correction factors were
used to calculate the emission level and compare reading to the applicable limit.
5) In case of measuring on the screened cable, the current limit shall be applied, otherwise the voltage
limit should be applied.
6) The following test mode(s) were scanned during the preliminary test:
Mode: N/A (EUT no any Telecommunicate Port)
7) After the preliminary scan, we found the following test mode(s) producing the highest emission
level and test date of the worst case was reported on the summary data page.
Mode: N/A
Data Sample:
Freq
Meter Reading
(MHz)
(dBuV)
x.xx
x.xx

C.F.
(dB)
x.xx

Corrected Reading
(dBuV/m)
59.26

Limits
(dBuV/m)
74.00

Margin
(dB)
-14.74

Reading Type
(P/Q/A)
P

C.F.(Correction Factor)=Insertion Loss (9.5dB) + Cable Loss
Corrected Reading = Metering Reading + C.F.
Margin=Corrected Reading - Limits
P=Peak Reading
Q=Quasi-peak
A=Average Reading
Comments: N/A

COMMON MODE CONDUCTED EMISSION LIMIT
AT TELECOMMUNICATION PORTS
CE-Mark ( EN 55022:1998 )
CLASS
B

Measuring
Band
150kHz-500kHz
500kHz-30MHz

Voltage limit dB(uV)
Q.P.
AV
84-74
74-64
74
64

Current limit dB(uA)
Q.P.
AV
40-30
30-20
30
20

Note: The lower limit sha ll apply at the transition frequency.

Page 16
Rev. 00

Report Number: 02E0683-E
December 5, 2002

MEASUREMENT PROCEDURE
(PRELIMINARY RADIATED EMISSION TEST)
1) The equipment was set up as per the test configuration to simulate typical actual usage per the
user’s manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8
meters is used which is placed on the ground plane as per EN 55022 (see Test Facility for the
dimensions of the ground plane used). When the EUT is a floor-standing equipment, it is placed
on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the
ground plane.
2) Support equipment, if needed, was placed as per EN 55022.
3) All I/O cables were positioned to simulate typical actual usage as per EN 55022.
4) The EUT received DC 5V power source from Host PC Power Supply (AC 230V/50Hz) to the
outlet socket under the turntable. All support equipment received 110VAC/60Hz power from
another socket under the turntable, if any.
5) The antenna was placed at 10 meter away from the EUT as stated in EN 55022. The antenna
connected to the analyzer via a cable and at times a pre-amplifier would be used.
6) The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test program was
started. Emissions were scanned and measured rotating the EUT to 360 degrees and positioning
the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal
polarization, to maximize the emission reading level.
7) The following test mode were scanned during the preliminary test:
Mode:
1

NORMAL MODE

8) After the preliminary scan, we found the following test mode producing the highest emission level.
Mode:

1.

Then, the EUT and cable configuration, antenna position, polarization and turntable position of the
above highest emission level were recorded for final testing.

Page 17
Rev. 00

Report Number: 02E0683-E
December 5, 2002

MEASUREMENT PROCEDURE
(FINAL RAIDATED EMISSION TEST)
1) EUT and support equipment were set up on the turntable as per step 8 of the preliminary test.
2) The Analyzer / Receiver scanned from 30MHz to 1000MHz. Emissions were scanned and
measured rotating the EUT to 360 degrees, varying cable placement and positioning the antenna 1
to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to
maximize the emission reading level.
3) Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position,
polarization and turntable position were recorded into a computer in which correction factors were
used to calculate the emission level and compare reading to the applicable limit and only Peak
reading is presented. If EUT emission level was less-2dB to the limit, then the emission signal was
re-checked using a Q.P. detector.
4) The test data of the worst case condition(s) was reported on the Summary Data page.
Data Sample:

Freq
(MHz)
x.xx

Meter
Reading
(dBuV)
x.xx

C.F.
(dB/m)
x.xx

Corrected
Reading
(dBuV/m)
30.82

Limits
(dBuV/m)
37.00

Reading
Type
P/Q/A
P

Margin
(dB)
-5.18

Pol.
H/V
V

C.F.(Correction Factor)=Antenna Factor + Cable Loss + Attenuator(3/6dB) - Amplifier Gain
Corrected Reading = Metering Reading + C.F.
Margin=Corrected Reading – Limits
P=Peak Reading
Q=Quasi-peak
A=Average Reading

H=Horizontal Polarization/Antenna
V=Vertical Polarization/Antenna

Comments: N/A
Calculation example:
Margin (dB) = Corrected Reading (dBuV/m) – Limits (dBuV/m)
Corrected Reading (dBuV/m)=Metering Reading (dBuV) + Corr Factor (dB/m)

RADIATED EMISSION LIMIT
Frequency
(MHz)

Distance
(m)

30-230

10

Maximum Field Strength Limit
(dBu V/m/ Q.P.)
30

230-1000

10

37

Note: The lower limit shall apply at the transition frequency.

Page 18
Rev. 00

Report Number: 02E0683-E
December 5, 2002

BLOCK DIAGRAM OF TEST SETUP
System Diagram of Connections between EUT and Simulators
EUT: KEYBOARD
Trade Name: Tai-Hao; Clicker
Model Number: F21 XP SERIES

1.PS/2
Mouse

2.Modem

EUT

3.Host PC

4.Monitor

5.Printer

Page 19
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SUMMARY DATA
(LINE CONDUCTED TEST)

Model Number: F21 XP SERIES

Location: Conducted Room

Tested by: Jimmy Chen
Test Mode: Mode 1
Test Results: Passed
Temperature: 30℃

Humidity: 61%RH

(The chart below shows the highest readings taken from the final data)

Freq
(MHz)
0.258
0.555
0.994
0.258
0.555
0.994

Frequency Range Investigated (150 kHz TO 30 MHz)
Meter
Corrected
Reading
Reading
C.F.
Reading
Limits
Margin
Type
(dBuV)
(dB)
(dBuV)
(dBuV)
(dB)
(P/Q/A)
46.72
0.04
46.76
61.51
-14.75
P
40.80
0.07
40.87
56.00
-15.13
P
41.13
0.10
41.23
56.00
-14.77
P
50.93
0.04
50.97
61.51
-10.54
P
42.24
0.07
42.31
56.00
-13.69
P
42.01
0.10
42.11
56.00
-13.89
P

Line
(L1/L2)
L1
L1
L2
L2
L2
L2

C.F.(Correction Factor)=Insertion Loss + Cable Loss
Corrected Reading = Metering Reading + C.F.
Margin=Corrected Reading - Limits
P=Peak Reading
Q=Quasi-peak
A=Average Reading

L1=Hot
L2=Neutral

Comments: N/A

Page 20
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SUMMARY DATA
(RADIATED EMISSION TEST)
Model Number: F21 XP SERIES

Location: Site # D

Tested by: Jimmy Chen

Polar: Vertical / Horizontal– 10m

Test Mode: Mode 1
Test Results: Passed
Temperature: 25℃

Humidity: 61%RH

(The chart below shows the highest readings taken from the final data)

Freq
(MHz)
39.180
48.030
120.050
180.350
498.880
500.350

Frequency Range Investigated (30 MHz TO 1000 MHz)
Meter
Corrected
Reading
C.F.
Reading
Limits
Margin
(dBuV)
(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
34.45
-9.65
24.80
30.00
-5.20
34.20
-8.09
26.12
30.00
-3.89
32.88
-9.01
23.87
30.00
-6.13
34.32
-8.19
26.13
30.00
-3.87
31.19
0.89
32.08
37.00
-4.92
31.43
0.90
32.33
37.00
-4.67

Reading
Type
P/Q/A
P
P
P
P
P
Q

Pol.
H/V
V
V
V
V
V
H

C.F.(Correction Factor)=Antenna Factor + Cable Loss - Amplifier Gain ( + Attenuator 6dB)
Corrected Reading = Metering Reading + C.F.
Margin=Corrected Reading - Limits
P=Peak Reading
H=Horizontal Polarization/Antenna
Q=Quasi-peak
V=Vertical Polarization/Antenna
A=Average Reading
Comments: N/A

Page 21
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SECTION 2 EN 61000-3-2 & EN 61000-3-3 (POWER HARMONICS &
VOLTAGE FLUCTUATION / FLICKER)

POWER HARMONICS MEASUREMENT
Port
Basic Standard
Limits
Temperature
Humidity
Test By

: AC mains
: EN 61000-3-2 (1995+A1: 1998+A2: 1998 + A14: 2000)
:
Class A, V Class D
: 210 C
: 58%
: Jimmy Chen

VOLTAGE FLUCTUATION/FLICKER MEASUREMENT
Port
Basic Standard
Limits
Temperature
Humidity
Test By

: AC mains
: EN 61000-3-3 (1995)
: §5 of EN 61000-3-3
: 210 C
: 58%
: Jimmy Chen

Block Diagram of Test Setup:
Harmonics & Flicker
Analyzer
+
Power Source
( PF 555 )

Power cord

EUT

Support Units

0.8m

Result:
Please see the attached test data.

Page 22
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 23
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 24
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 25
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 26
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 27
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 28
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 29
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 30
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 31
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 32
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SECTION 3 IEC 61000-4-2 (ELECTROSTATIC DISCHARGE)
ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST
Port
Basic Standard
Requirements

: Enclosure
: IEC 61000-4-2
: ±8 kV (Air Discharge)
±4kV (Contact Discharge)
±4kV (Indirect Discharge)
Performance Criteria : B ( Standard require )
Temperature/Humidity : 190 C /58%
Pressure
: 1015 mbar
Test By
: Jimmy Chen

Block Diagram of Test Setup:

VCP

EUT

Support units

HCP

>1m

Wooden Table

0.8m

Ground Reference Plane

Page 33
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Test Procedure:
1. The EUT was located 0.1 m minimum from all side of the HCP.
2. The indirect support units were located 1 m minimum away from the EUT, but direct support unit
was/were located at same location as EUT on the HCP and keep at a distance of 10 cm with EUT.
3. A communication test program was loaded and executed in Windows mode.
4. PC sent trans mit data to remote side via EUT.
5. As per the requirement of EN 55024; applying direct contact discharge at the sides other than front
of EUT at minimum 50 discharges (25 positive and 25 negative) if applicable, can’t be applied
direct contact discharge side of EUT then the indirect discharge shall be applied. One of the test
points shall be subjected to at least 50 indirect discharge (contact) to the front edge of horizontal
coupling plane.
6. Other parts of EUT where it is not possible to perform contact discharge then selecting appropriate
points of EUT for air discharge, a minimum of 10 single air discharges shall be applied.
7. The application of ESD to the contact of open connectors is not required.
8. Putting a mark on EUT to show tested points. The following test condition was followed during the
tests.
Note: As per IEC 61000-4-2:2001, with two 470k bleed resistors cable is connected between the EUT
and HCP during the test applicable for power ungrounded or battery operating unit only.
The electrostatic discharges were applied as follows:
Amount of
Voltage
Coupling
Result (Pass/Fail)
Discharges
Mini 25 /Point
Contact Discharge
Pass
±4kV
Mini 25 /Point
Indirect Discharge HCP (Front)
Pass
±4kV
Mini 25 /Point
±4kV
Indirect Discharge VCP (Back)
Pass
Mini 25 /Point
±4kV
Indirect Discharge VCP (Left)
Pass
Mini 25 /Point
±4kV
Indirect Discharge VCP (Right)
Pass
Mini 10 /Point
Air Discharge
Pass
±8kV
** The tested points to EUT, please refer to attached page.
(Blue arrow mark for contact discharge, red arrow mark for air discharge.)

Performance & Result:
Criteria A:

V

Criteria B:

Criteria C:

The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Temporary loss of function is allowed, provided the functions self recoverable or
can be restored by the operation of controls.

V

PASS

FAILED

Observation: No any function degraded during the tests.

Page 34
Rev. 00

Report Number: 02E0683-E
December 5, 2002

The Tested Points of EUT
(Photo 1 of 6)

(Photo 2 of 6)

Page 35
Rev. 00

Report Number: 02E0683-E
December 5, 2002

(Photo 3 of 6)

(Photo 4 of 6)

Page 36
Rev. 00

Report Number: 02E0683-E
December 5, 2002

(Photo 5 of 6)

(Photo 6 of 6)

Page 37
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SECTION 4

IEC 61000-4-3 (RADIATED ELECTROMAGNETIC FIELD )

RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST
Port
Basic Standard
Requirements
Performance Criteria
Tester
Temperature
Humidity
Pressure
Note

:
:
:
:
:
:
:
:
:

Enclosure
IEC 61000-4-3
3 V/m / with 80% AM. 1kHz Modulation
A (Standard require)
Jimmy Chen
23℃
72%
1015 mbar
The EUT not have acoustic interfaces, the annex A of EN 55024
should not be applied.

Block Diagram of Test Setup:
3m

7x3x3 Chamber
EUT &
Support

1.5m
0.8m

Power Amp

Signal
Generator

EUT Monitoring by
using a camera

PC Controller to control
S.G. & PA as well as
forward power

Control Room

Page 38
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Test Procedure:
1. The EUT and support units were located at the edge of supporting table keep 3 meter away from
transmitting antenna, it just the calibrated square area of field uniformity.
2. Adjusting the cables to be exposed to the electromagnetic filed as possible.
3. Performing a Radiated Emission Scan in range of 30 to 1000 MHz prior to do RS test and records
the more higher emission frequencies for the reference of RS test, due to antenna effectiveness.
4. Adjusting the monitoring camera to monitor the “H” message as clear as possible.
5. Setting the testing parameters of RS test software per IEC 61000-4-3.
6. Referring to the tested data of step 3 to performing the RS test from 80 to 1000 MHz.
7. Recording the test result in following table.
8. Changing the EUT to the other side and repeat step 3 to 6, until 4 sides of EUT were verified.
IEC 61000-4-3 Final test conditions:
Test level
: 3V/m
Steps
: 1 % of fundamental
Dwell Time
: 3 sec
Range (MHz)
Field
Modulation
80-1000
3V
Yes
80-1000
3V
Yes
80-1000
3V
Yes
80-1000
3V
Yes
80-1000
3V
Yes
80-1000
3V
Yes
80-1000
3V
Yes
80-1000
3V
Yes

Polarity
H
V
H
V
H
V
H
V

Position (°)
Front
Front
Right
Right
Back
Back
Left
Left

Result (Pass/Fail)
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass

Page 39
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Performance & Result:
V

Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
Criteria B:

The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self recoverable or
can be restored by the operation of controls.

V

PASS

FAILED

Observation: No any function degraded during the tests.

Page 40
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SECTION 5 IEC 61000-4-4 (FAST TRANSIENTS/BURST)
FAST TRANSIENTS/BURST IMMUNITY TEST
Port
Basic Standard
Requirements
Performance Criteria
Temperature
Humidity
Pressure
Test By

: On Power Lines
: IEC 61000-4-4
: ±1kV for Power Supply Lines
: B (Standard require)
: 210 C
: 58%
: 1015 mbar
: Jimmy Chen

Block Diagram of Test Setup:

EUT

AC
Line

EFT/Burst/Surge
Generator

80cm

Support
Units

Non-Conductive Table

Controller Computer

Page 41
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Test Procedure:
1. The EUT and support units were located on a wooden table 0.8 m away from ground reference
plane.
2. A 1.0 meter long power cord was attached to EUT during the test.
3. The length of communication cable between communication port and clamp was keeping within 1
meter.
4. A test program was loaded and executed in Windows mode.
5. The data was display on the monitor and filling the screens.
6. The test program exercised related support units sequentially.
7. Repeating step 3 to 6 through the test.
8. Recording the test result as shown in following table.
Test conditions :
Impulse Frequency: 5kHz
Tr/Th: 5/50ns
Burst Duration: 15ms
Burst Period: 300mS
Inject Line
L1
N
PE
L1+N
L1+PE
N+PE
L1+N+PE

Voltage kV
+/- 1
+/- 1
+/- 1
+/- 1
+/- 1
+/- 1
+/- 1

Inject Method
Direct
Direct
Direct
Direct
Direct
Direct
Direct

Result (Pass/Fail)
Pass
Pass
Pass
Pass
Pass
Pass
Pass

Performance & Result:
V

Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or
can be restored by the operation of controls.

V

PASS

FAILED

Observation: No any function degraded during the tests.

Page 42
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SECTION 6 IEC 61000-4-5 ( SURGE IMMUNITY )
SURGE IMMUNITY TEST
Port

: Power Cord

Basic Standard

: IEC 61000-4-5

Requirements

: ±1kV (Line to Line of Power Port)
±2kV (Line to Earth of Power Port)

Performance Criteria : B (Standard require)
Temperature

: 210 C

Humidity

: 58%

Pressure

: 1015 mbar

Test By

: Jimmy Chen

Block Diagram of Test Setup:

To AC
Source

Surge Immunity
Test

EUT & Support
Units

80 mm

Controller Computer

Page 43
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Test Procedure:
1. The EUT and support units were located on a wooden table 0.8 m away from ground floor.
2. A test program was loaded and executed in Windows mode.
3. The data was display on the monitor and filling the screens.
4. The test program exercised related support units sequentially.
5. Repeating step 3 to 4 through the test.
6. Recording the test result as shown in following table.
Test conditions:
Voltage Waveform
Current Waveform
Polarity
Phase angle
Number of Test

: 1.2/50 µs
: 8/20 µs
: Positive/Negative
: 00 , 900 , 2700
:5

Coupling Line
L1-L2、 L1-PE、 L2-PE
L1-L2、 L1-PE、 L2-PE
L1-PE、L2-PE
L1-PE、L2-PE

Voltage (kV)
1
1
2
2

Polarity
Positive
Negative
Positive
Negative

Coupling Method Result (Pass/Fail)
Capacitive
Pass
Capacitive
Pass
Capacitive
Pass
Capacitive
Pass

Performance & Result:
V

Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can
be restored by the operation of controls.

V

PASS

FAILED

Observation: No any function degraded during the tests.

Page 44
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SECTION 7 IEC 61000-4-6

(CONDUCTED DISTRBANCE/INDUCED BY
RADIO-FREQUENCY FIELD)

CONDUCTED DISTURBANCE, INDUCED BY RADIO-FREQUENCY FIELDS
Port
Basic Standard
Requirements
Injection Method
Performance Criteria
Temperature
Humidity
Pressure
Test By

: AC Port
: IEC 61000-4-6
: 3V with 80% AM. Modulation
: CDN-M3
: A (Standard require)
: 240 C
: 72%
: 1015 mbar
: Jimmy Chen

Block Diagram of Test Setup:
10 cm isolation
supporter

0.1m< L <0.3m

EUT and
Support units
CDN

Power
Amplifier

PC
Controller

Ground Reference Plane

Page 45
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Top view:

3 - 5 cm isolation supporter

Support
Units
Ground Reference Plane

EUT &
Support
Units

EM-Cla
mp
Power
Amplifier

PC

Controller

10 cm isolation supporter

Test Procedure:
1.
2.
3.
4.
5.

The EUT and support units were located at a ground reference plane with the interposition of a 0.1
m thickness insulating support and the CDN was located on GRP directly.
Transmit data message were displayed on screen of Monitor.
Adjusting the monitoring camera to monitor the transmit data message as clear as possible.
Setting the testing parameters of CS test software per IEC 61000-4-6.
Recording the test result in following table.

Page 46
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Test conditions:
Frequency Range
Frequency Step
Dwell Time

: 0.15MHz-80MHz
: 1% of fundamental
: 3 sec

Range (MHz)

Field

Modulation

Result (Pass/Fail)

0.15-80

3V

Yes

Pass

Performance & Result:
V

Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
Criteria B:

The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufactur er, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self-recoverable or
can be restored by the operation of controls.

V

PASS

FAILED

Observation: No any function degraded during the tests.

Page 47
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SECTION 8 IEC 61000-4-8 (POWER FREQUENCY MAGNETIC FIELD
IMMUNITY TEST)
POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
Port
Basic Standard
Requirements
Performance Criteria
Temperature
Humidity
Pressure
Test By

: Enclosure
: IEC 61000-4-8
: 1 A/m
: A (Standard Required)
: N/A
: N/A
: N/A
: N/A

Block Diagram of Test Setup:

1/2 Dimension
of EUT

Induction
Coil

EUT

10mm thick
Insulation Support

Signal
Generator

To
Earth Ground

To
Earth Ground

Page 48
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Test Procedure:
1.
2.
3.
4.
5.
6.
7.
8.
9.

The EUT and support units were located on Ground Reference Plane with the interposition of a
0.1 m thickness insulation support.
Putting the induction coil on horizontal direction.( X direction )
A test program was loaded and executed in Windows mode.
The data was sent to the screen of EUT and filling the screen with upper case of “H” patterns.
The test program exercised related support units sequentially.
Repeating step 3 to 5 through the test.
Recording the test result as shown in following table.
Rotating the induction coil by 900 ( Y direction ) then repeat step 3 to 7.
Rotating the induction coil by 900 again ( Z direction ) then repeat step 3 to 7.

*. Test conditions:
Field Strength:
1A/m
Power Freq.:
50Hz
Orientation:
X, Y, Z
Orientation

Field

Result (Pass/Fail)

Remark

**Note: Not applicable, because no any component can be influenced by power magnetic fields.

Performance & Result:
□ Criteria A: The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
□ Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
□ Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can
be restored by the operation of controls.

PASS

FAILED

Observation: N/A (EUT Without any magnetic component)
Page 49
Rev. 00

Report Number: 02E0683-E
December 5, 2002

SECTION 9 IEC 61000-4-11
(VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS )

VOLTAGE DIPS / SHORT INTERRUPTIONS
Port
Basic Standard
Requirement

: AC mains
: IEC 61000-4-11 (1994)
: PHASE ANGLE 0, 45, 90, 135, 180, 225, 270, 315 degrees

Voltage
Dips

Test Level
% UT
<5
70

Reduction
(%)
>95
30

Duration
( periods )
0.5
25

Performance
Criteria
B
C

Voltage
Interceptions

Test Level
% UT
<5

Reduction
(%)
>95

Duration
( periods )
250

Performance
Criteria
C

Test Interval
Temperature
Humidity
Pressure
Test By

: Min. 10 sec.
: 210 C
: 58%
: 1015 mbar
: Jimmy Chen

Block Diagram of Test Setup:

To AC
Source

Dips/Interruption and

EUT
&
Support Units

Variations Simulator

80 mm

Controller Computer

Page 50
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Test Procedure:
1.
2.
3.
4.
5.
6.
7.
8.

The EUT and support units were located on a wooden table, 0.8 m away from ground floor.
A test program was loaded and executed in Windows mode.
The data was displayed on the monitor and filling the screens.
The test program exercised related support units sequentially.
Setting the parameter of test and then Perform the test software of test simulator.
Conditions changes to occur at 0 degree crossover point of the voltage waveform.
Repeating step 3 to 4 through the test.
Recording the test result in the test record form.

Test conditions:
The duration with a sequence of three dips/interruptions with interval of 10 s minimum
( Between each test event )
Voltage Dips:
Test Level
Reduction
Duration
Observation
Meet Performance
% UT
(%)
( periods)
Criteria
0
100
0.5
Normal
A
70
30
25
Normal
A
Voltage Interruptions:
Test Level
Reduction
% UT
(%)
0
100

Duration
Observation
( periods)
250
Host PC shut down, but
EUT can be auto
recovered after Host PC
restart.

Meet Performance
Criteria
C

Performance & Result:
Criteria A:

Criteria B:

Criteria C:

The apparatus continues to operate as intended. No degradation of performance or
loss of function is allowed below a performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases the performance level may
be replaced by a permissible loss of performance.
The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by
the manufacturer, when the apparatus is used as intended. In some cases the
performance level may be replaced by a permissible loss of performance. During
the test, degradation of performance is however allowed.
Temporary loss of function is allowed, provided the functions self recoverable or
can be restored by the operation of controls.

V

PASS

FAILED

Page 51
Rev. 00

Report Number: 02E0683-E
December 5, 2002

APPENDIX 1

PHOTOGRAPHS OF TEST SETUP

Page 52
Rev. 00

Report Number: 02E0683-E
December 5, 2002

LINE CONDUCTED EMISSION TEST (EN 55022)

Page 53
Rev. 00

Report Number: 02E0683-E
December 5, 2002

RADIATED EMISSION TEST (EN 55022)

Page 54
Rev. 00

Report Number: 02E0683-E
December 5, 2002

POWER HARMONIC & VOLTAGE FLUCTUATION / FLICKER TEST
(EN 61000-3-2, EN 61000-3-3)

Page 55
Rev. 00

Report Number: 02E0683-E
December 5, 2002

ELECTROSTATIC DISCHARGE TEST (IEC 61000-4-2)

Page 56
Rev. 00

Report Number: 02E0683-E
December 5, 2002

RADIATED ELECTROMAGNETIC FIELD (IEC 61000-4-3)
Front View

Back View

Page 57
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Left View

Right View

Page 58
Rev. 00

Report Number: 02E0683-E
December 5, 2002

FAST TRANSIENTS/BURST TEST & SURGE IMMUNITY TEST
(IEC 61000-4-4/5)

Page 59
Rev. 00

Report Number: 02E0683-E
December 5, 2002

CONDUCTED DISTURBANCE, INDUCED BY RADIO-FREQUENCY FIELDS
TEST (IEC 61000-4-6)

Page 60
Rev. 00

Report Number: 02E0683-E
December 5, 2002

VOLTAGE DIPS / INTERRUPTION TEST (IEC 61000-4-11)

Page 61
Rev. 00

Report Number: 02E0683-E
December 5, 2002

APPENDIX 2

PHOTOGRAPHS OF EUT

Page 62
Rev. 00

Report Number: 02E0683-E
December 5, 2002

Page 63
Rev. 00

Report Number: 02E0683-E
December 5, 2002

APPENDIX 3

CONDUCTED EMISSION PLOT
RADIATED EMISSION DATA

Page 64
Rev. 00

No. 199, Chung Sheng Road,
Hsin Tien City, Taipei,
Taiwan, R.O.C.
Tel:02-2217-0894 Fax:02-2217-1254
Data#: 18

Trace: 7

File#: 0683c.emi

Date: 2002-12-04

8

Ref Trace:

Condition: LINE
Report No. : 02E0683
Test Engr. : JIMMY CHEN
Company
: TAIWAN TAI-HAO ENTERPRISE CO., LTD.
EUT
: F21 XP SERIES
Test Config : EUT / ALL PERIPHERALS
Type of Test: EN55022 CLASS B
Mode of Op. : NORMAL MODE
Page: 1
Read
Limit
Over
Freq Level Factor Level
Line Limit Remark
_________ ______ ______ ______ ______ ______ ______
MHz
dBuV
dB
dBuV
dBuV
dB
1
2
3
4
5
6

0.158
0.258
0.410
0.555
0.994
6.488

Time: 20:08:28

46.34
46.72
40.76
40.80
41.13
38.42

0.03
0.04
0.06
0.07
0.10
0.29

46.37
46.76
40.82
40.87
41.23
38.71

65.56
61.51
57.64
56.00
56.00
60.00

-19.19
-14.75
-16.82
-15.13
-14.77
-21.29

Peak
Peak
Peak
Peak
Peak
Peak

No. 199, Chung Sheng Road,
Hsin Tien City, Taipei,
Taiwan, R.O.C.
Tel:02-2217-0894 Fax:02-2217-1254
Data#: 17

Trace: 15

File#: 0683c.emi

Date: 2002-12-04

16

Ref Trace:

Condition: NEUTRAL
Report No. : 02E0683
Test Engr. : JIMMY CHEN
Company
: TAIWAN TAI-HAO ENTERPRISE CO., LTD.
EUT
: F21 XP SERIES
Test Config : EUT / ALL PERIPHERALS
Type of Test: EN55022 CLASS B
Mode of Op. : NORMAL MODE
Page: 1
Read
Limit
Over
Freq Level Factor Level
Line Limit Remark
_________ ______ ______ ______ ______ ______ ______
MHz
dBuV
dB
dBuV
dBuV
dB
1
2
3
4
5
6

0.158
0.183
0.258
0.410
0.555
0.994

Time: 20:07:59

45.66
46.74
50.93
41.92
42.24
42.01

0.03
0.03
0.04
0.06
0.07
0.10

45.69
46.77
50.97
41.98
42.31
42.11

65.56
64.33
61.51
57.64
56.00
56.00

-19.87
-17.56
-10.54
-15.66
-13.69
-13.89

Peak
Peak
Peak
Peak
Peak
Peak

No. 199, Chung Sheng Road,
Hsin Tien City, Taipei,
Taiwan, R.O.C.
Tel:02-2217-0894 Fax:02-2217-1254
Data#: 1
D-Site

File#: 0683d.emi

Date: 2002-12-04

Condition: VERTICAL / 10m
Report No. : 02E0683
Test Engr. : JIMMY CHEN
Company
: TAIWAN TAI-HAO ENTERPRISE CO., LTD.
EUT
: F21 XP SERIES
Test Config : EUT / ALL PERIPHERALS
Type of Test: EN55022 CLASS B
Mode of Op. : NORMAL MODE
Page: 1
Read
Limit
Over
Freq Level Factor Level
Line Limit Remark
_________ ______ ______ ______ ______ ______ ______
MHz
dBuV
dB dBuV/m dBuV/m
dB
1
2
3
4
5
6
7
8
9

39.180
48.030
60.080
74.530
120.050
180.350
242.800
355.450
498.880

34.45 -9.65
34.20 -8.09
34.29 -10.71
34.71 -12.59
32.88 -9.01
34.32 -8.19
35.40 -8.56
30.16 -2.82
31.19
0.89

24.80
26.12
23.58
22.12
23.87
26.13
26.84
27.34
32.08

30.00 -5.20 Peak
30.00 -3.89 Peak
30.00 -6.42 Peak
30.00 -7.88 Peak
30.00 -6.13 Peak
30.00 -3.87 Peak
37.00 -10.16 Peak
37.00 -9.66 Peak
37.00 -4.92 Peak

Time: 22:30:58

No. 199, Chung Sheng Road,
Hsin Tien City, Taipei,
Taiwan, R.O.C.
Tel:02-2217-0894 Fax:02-2217-1254
Data#: 2
D-Site

File#: 0683d.emi

Date: 2002-12-04

Condition: HORIZONTAL / 10m
Report No. : 02E0683
Test Engr. : JIMMY CHEN
Company
: TAIWAN TAI-HAO ENTERPRISE CO., LTD.
EUT
: F21 XP SERIES
Test Config : EUT / ALL PERIPHERALS
Type of Test: EN55022 CLASS B
Mode of Op. : NORMAL MODE
Page: 1
Read
Limit
Over
Freq Level Factor Level
Line Limit Remark
_________ ______ ______ ______ ______ ______ ______
MHz
dBuV
dB dBuV/m dBuV/m
dB
1
2
3
4
5
6
7
8

40.400
59.800
73.730
119.950
179.930
240.000
355.330
500.350

32.15 -9.50
31.82 -10.53
31.12 -12.59
32.44 -9.01
31.80 -8.12
31.78 -8.58
31.78 -2.82
31.43
0.90

22.65
21.29
18.53
23.43
23.68
23.20
28.96
32.33

30.00 -7.35 Peak
30.00 -8.71 Peak
30.00 -11.47 Peak
30.00 -6.57 Peak
30.00 -6.32 Peak
37.00 -13.80 Peak
37.00 -8.04 Peak
37.00 -4.67 Peak

Time: 22:41:13



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat PDFWriter 5.0 for Windows
Create Date                     : 2002:12:06 09:45:47Z
Modify Date                     : 2009:01:08 13:43:12+08:00
Metadata Date                   : 2009:01:08 13:43:12+08:00
Creator Tool                    : Microsoft Word
Format                          : application/pdf
Title                           : 02E0683-E_太豪 KEYBOARD_.doc
Creator                         : lsandy
Document ID                     : uuid:7867eb67-0052-4135-bf4a-8be63d8954b2
Instance ID                     : uuid:2fd3ec93-2d9d-46d9-bd94-f3b244e902fd
Page Count                      : 68
Author                          : lsandy
EXIF Metadata provided by EXIF.tools

Navigation menu