2008 Ballast Cat Revised
203335-Attachment 203335-Attachment 203335-Attachment 043168 Batch4 unilog cesco-content
2021-Brochure 1 2021-Brochure_1 2021-Brochure_1 043168 Batch4 unilog cesco-content
101670-Catalog 101670-Catalog 101670-Catalog 043168 Batch5 unilog cesco-content
2014-10-17
: Pdf 17727-Attachment 17727-Attachment 002853 Batch10 unilog
Open the PDF directly: View PDF .
Page Count: 98
Download | |
Open PDF In Browser | View PDF |
GE Consumer & Industrial Lighting GE Ballast Products Catalog 2008 ballasts 2008 product catalog US/Canada Customer Ordering and Tracking—www.geelitenet.com For detailed ballast and lamp specifications—www.gelighting.com For order, technical or warranty assistance, call: 1-888-GEBALLAST (432-2552) OEM Customer Service: (T) 1-800-833-4933, (F) 1-800-327-0588 GE Lighting Headquarters, Nela Park, 1975 Noble Rd., Cleveland, OH 44112, (T) 216-266-2121 Transforming the POWER of light™ GE has a policy of continuous improvement of its products and reserves the right to change materials and specifications without notice. © 2007 GE Company Pub. No. 71883 PC48878 Transforming the POWER of light™ gelighting.com GE Consumer & Industrial Lighting GE Consumer & Industrial Lighting The future can seem pretty intimidating: Our known reserves of oil and natural gas are expected to be depleted by 2045, the climate is changing, and more than a billion people lack clean water. At GE, we believe some of the world’s most pressing challenges present an opportunity to do what we do best: Imagine and build innovative solutions that benefit our customers and society at large. As a global leader in energy, technology, manufacturing and infrastructure, GE is uniquely suited to help solve environmental challenges, today and for generations to come. Our customers want a more prosperous, cleaner future. By harnessing our most abundant renewable resource—the imagination of our people—we can create that future with them. We are taking a new approach to solving some of our customers’ toughest environmental problems. We call it ecomagination. GE Ultra High Efficiency Design is Ultra Cool! Product Warranties Results: Combine GE’s Ultra ballasts with cool running fixtures to achieve maximum system performance in hot temperatures. GE provides the Ultra Cool™ system certification with high grade fixture systems which means a 5 year 55°C max ambient warranty. Light your world with a brand you can trust—GE. sm Impact of ecomagination: A manufacturing and warehouse facility was looking to reduce costs and greenhouse gas emissions: Existing Lighting 400W MH std. CWA Light output* Size Energy Rate/Burning Hours Total Watts per Fixture Energy Used RoHS compliant** 23,000 mean lumens at 8,000 hours (19,200 lumens at 12,000 hours) 100,000 sq. ft. – 300 fixtures 10¢ kWh/5,000 per year 458 $68,700 No Proposed Lighting 4-Lamp T5WM HO with UltraStart® Ballast Light output* 19,000 mean lumens at 12,000 hours Watts per Fixture 216 Energy Used $32,400 Energy Saved $36,300 RoHS compliant** Yes If your GE lamp or ballast, when installed and used properly, fails during its warranty period because of defects in materials or workmanship, our warranties provide for purchase price credits or replacement. Of course, every lamp, ballast and system is different and warranty details vary, so check the individual warranty for your product at http://genet.gelighting.com/LightProducts/html/warranties.htm. Environmental Impact Watts Saved Greenhouse gases (Co2) SO2 The equivalent effect of: Equivalent Forestation Equivalent Cars 363,000 kilowatt-hours per year Reduced by 519,090 lbs. per year Reduced by 2,030 lbs. per year 71 acres 45 cars removed from the roads for a year System Limited Warranty GE Lamps operating on GE Ballast Our heritage, our future We believe that better technology is the answer to our customers’ environmental challenges. And we are confident we can find tomorrow’s solutions to those challenges just as we have since the days of our founder, Thomas Edison. Throughout our 115-year history, we have invented solutions to meet our customers’ greatest needs. Over many years, we have developed one of the broadest ranges of environmentally advanced technologies. We will build on this legacy of success by researching and developing next-generation clean technologies. Our goal is to be a leader in bringing clean energy, air, water and improved quality of life to all of the world’s citizens. *Mean lumen measured at 40% of rated life **RoHS compliant: European Directive (2002/95EC on the Restriction of Hazardous Substances) states that (beyond certain limited exemptions) electrical and electronic products shall not contain lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls (PBBs), or polybrominated diphenyl ethers (PBDEs). GE’s UltraStart® ballasts use lead-free solder and other environmentally preferable materials that meet the RoHS directive. RoHS-compliant ballasts are GE’s commitment to helping our customers meet their disposal needs now, and in the future. 2 GE has been a leader in innovative lighting technologies for over 100 years. Our name on the label is virtually synonymous with dependable, efficient, high-quality products—and that is why we are totally confident in the system performance and reliability of our lamps and ballasts. Also it is why we are willing to back them with a limited warranty that provides excellent coverage against defects in materials and workmanship. Compact Fluorescent Lamp Double Biax®: 13-, 18-, 26-watt 4-pin base Triple Biax®: 13-, 18-, 26-, 32-, 42-watt 2D®: 10-, 16-, 21-, 28-, 38-watt Warranty * 1 year after date of purchase or 4000 hrs. 1 year after date of purchase or 4000 hrs. 1 year after date of purchase or 4000 hrs. Electronic Ballast Warranty 5 years from date of manufacture 5 years from date of manufacture 5 years from date of manufacture Electromagnetic Ballast Warranty 2 years from date of manufacture 2 years from date of manufacture 2 years from date of manufacture Linear Fluorescent Lamp Warranty Electronic Ballast Warranty Electromagnetic Ballast Warranty F25T12** F28T8, F32T8, F32T8WM F32T8/XL, F32T8/XL/HL, F32T8/XL/WM F32T8 SXL, F32T8/25W F14T5HE, F21T5HE, F28T5HE, F35T5HE, F54T5HO F14T5/WM, F21T5/WM, F28T5/WM, F35T5/WM, F54T5/WM F28WT5/HL F96T8 F96T8/XL, F96T8/XL/WM. F96T8/XL/WMP 3 years after date of purchase or 10,500 hrs. 3 years after date of purchase or 10,500 hrs. 3 years after date of purchase or 12,500 hrs. 4.5 years after date of purchase or 15,750 hrs. 4 years after date of purchase or 14,000 hrs. 5 years from date of manufacture 5 years from date of manufacture 5 years from date of manufacture 5 years from date of manufacture 5 years from date of manufacture 2 years from date of manufacture 3.5 years after date of purchase or 12,500 hrs. 5 years from date of manufacture 3 years after date of purchase or 10,500 hrs. 2 years after date of purchase or 8,000 hrs. 3 years after date of purchase or 10,500 hrs. 5 years from date of manufacture 5 years from date of manufacture 5 years from date of manufacture HID Lamp Warranty Electronic Ballast Warranty Electromagnetic Ballast Warranty CMH® ConstantColor® SPXX 250-, 320-, 1 year after date of purchase or 5000 hrs. 5 years from date of manufacture 350-, 400-watt PulseArc® 250-, 320-, 350-, 400-watt 1 year after date of purchase or 5000 hrs. 5 years from date of manufacture *Based on whichever comes first ® ® ® **On GE Normal light output UltraMax , ProLine or Multivolt Proline instant start ballasts ***See warranties at gelighting.com for specific lamp cycle requirements for instant start & program start ballasts. Cycle time with program start ballasts shall be 15 minutes or greater ****All covRguard® lamps are included 195 Quick Reference Guides gelighting.com Table of contents 4 Product overview 6 Quick reference ballast selection guide 16 Quick reference lamp to ballast selection guide T8 Fluorescent Ballasts PRODUCTS Sign Ballasts 36 Understanding T8 Fluorescent Ballasts T8 INSTANT START BALLASTS 38 UltraMax® Instant Start Multi-Voltage High Efficiency 38 For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps 45 For 46 – 59W 4 ft–8 ft Slimline Lamps 46 ProLine® T8 Multivolt 120V–277V 46 For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps 51 For 46 – 59W 4 ft–8 ft Slimline Lamps 52 ProLine® T8 Multivolt, High Output 120V–277V 52 For 44 – 86W 4 ft–8 ft High Output Lamps 53 ProLine® T8 Instant Start High Performance 53 For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps 57 For 46 – 59W 4 ft–8 ft Slimline Lamps 58 Residential Grade ProLine® T8 120V 58 For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps 59 Electromagnetic T8 Ballasts 59 For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps T8 PROGRAMMED START BALLASTS 60 UltraStart® T8 Programmed Start 60 For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps 69 T8 Dimming 69 For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps 72 Wiring Diagrams 75 Case Dimensions 106 Understanding Sign Ballasts 107 Sign Ballasts 107 For T12 High Output Lamps 115 Wiring Diagrams 119 Case Dimensions 120 Understanding Compact Fluorescent Ballasts 123 ProLine® CFL Electronic Ballasts 123 For 13 – 42W T4 CFL Lamps 125 For 40W Biax® CFL Ballasts 128 For 5 – 26W Preheat CFL Lamps 129 CFL Magnetic Ballasts 129 For 5 - 26W Preheat CFL Lamps 130 For 36 – 40W CFL Lamps 131 Wiring Diagrams 133 Case Dimensions T5 Fluorescent Ballasts HID Electromagnetic Ballasts 76 Understanding T5 Electronic Programmed Start Ballasts T5 ELECTRONIC PROGRAMMED START BALLASTS 77 T5 High Efficiency Programmed Start 77 For F14 (2 ft), F21 (3 ft), F28 (4 ft), F35 (5 ft) HE T5 Lamps 79 T5 High Output Programmed Start 79 For F24 (2 ft), F39 (3 ft), F54 (4 ft), F80 (5 ft) HO T5 Lamps 82 Wiring Diagrams 83 Case Dimensions 142 Understanding Electromagnetic HID Ballasts 144 Metal Halide 144 For 20 – 175W Metal Halide HID Lamps 149 For 250 – 1500W Metal Halide HID Lamps 155 Pulse Start 155 For 175 – 1000W Pulse Start Metal Halide HID Lamps 162 High Pressure Sodium 162 For 50 – 150W High Pressure Sodium HID Lamps 166 For 250 – 1000W High Pressure Sodium HID Lamps 170 High Intensity Discharge Lamp Ballast Kits 174 Enclosed and Potted Metal Halide 178 F-Can and Post Mount High Pressure Sodium HID ACCESSORIES 179 Replacement Capacitors 179 Replacement Ignitors for Pulse Start Lamps (MH & HPS) 179 Other Accessories 180 Wiring Diagrams 184 Case Dimensions 134 Understanding Electronic UltraMax® HID Ballasts 135 Electronic HID 135 For 20 – 150W Pulse Start HID Lamps 139 For 250 – 400W Pulse Start HID Lamps 140 Wiring Diagrams 141 Case Dimensions Glossary Ballast Cross Reference Matrix Contact Information Warranty Information HID Electronic Ballasts 186 190 194 195 Compact Fluorescent Ballasts 3 HID Electromagnetic Ballasts 84 Understanding T12 Electronic Ballasts T12 ELECTRONIC BALLASTS 85 ProLine® T12 Multivolt 120V–277V 85 For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps 87 For T12 (4 ft–8 ft) Slimline Lamps T12 HIGH OUTPUT BALLASTS 88 For T12 High Output Lamps T12 MAGNETIC BALLASTS 90 For 2 ft, Circleline, Preheat T12 Lamps 93 For F30, F34/F40 (4 ft) T12 Lamps 97 For T12 4 ft–8 ft Slimline Lamps 99 For T12 High Output Lamps FLUORESCENT ACCESSORIES 100 Starters 100 Sockets 101 Wiring Diagrams 104 Case Dimensions HID Electronic Ballasts Sign Ballasts T12 Electronic Ballasts T12 Fluorescent Ballasts T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length. Compact Fluorescent Ballasts T5 Fluorescent Ballasts Inside front cover is in cover file T8 Fluorescent Ballasts gelighting.com 2008 Ballast Product Catalog This catalog contains North Ecomagination is GE’s commitment to create products that America ballast and lamp help our customers improve their environmental and operating data as of December 2007. performance. GE’s UltraStart® T5 and T8 programmed start and Additional information is GE UltraMax® Instant Start ballasts are among the highest constantly being uncovered energy-efficient ballasts available and contribute to significant through research and testing, reductions in energy consumption and the curbing of which may modify the greenhouse gas emissions. SM UltraMax® T8 Electronic Ballast UltraStart® T8 Electronic Ballast data given herein. Changes may be made at any time. RoHS compliant: ProLine® Electronic Ballast The data and suggested European Directive (2002/95EC on the Restriction of Hazardous Substances) states that (beyond certain limited exemptions) electrical and electronic products shall not contain lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls (PBBs), or polybrominated diphenyl ethers (PBDEs). GE’s electronic ballasts use lead-free solder and other environmentally preferable materials that meet the RoHS directive. Although not required in the U.S., RoHS-compliant ballasts show GE’s commitment to helping our customers meet their disposal needs now, and in the future. GE encourages customer awareness on the importance of reducing hazardous materials and getting ahead of complying with environmental trends. Look for the RoHS-compliant mark on GE ballasts. Offered in dedicated or multivolt (120-277V), these highperformance T8 instant start ballasts are long life, less than 10% THD and most models also meet minimum efficiency requirements of the NEMA Premium® ballast program. UltraMax® Electronic Ballast Electromagnetic Ballast (Magnetic Ballast) applications should not be taken as representations or warranties as to the suitability of a ballast for a particular application. A family of high-efficiency GE T8 instant-start electronic linear fluorescent ballasts designed to optimize GE’s T8 Ultra lamps for optimal system energy savings. UltraMax® ballasts have a lamp-friendly low-lamp-current crest factor and virtually “read” and adapt to incoming voltage from 108V to 305V. Other features include UL Type CC Anti-Arc Rating and anti-striation control to eliminate lamp striations and spiraling. All UltraMax® ballasts exceed 90% efficiency and the NEMA Premium® ballast program minimum efficiency requirements. UltraStart® Electronic Ballast UltraStart® ballasts are a family of high-efficiency GE Program Start (see page 36) electronic linear fluorescent ballasts designed to optimize GE’s T8 and T5 Ultra lamps in frequently switched applications. Instant Start ballasts provide approximately 10,000 starts before 50% of lamp failure. UltraStart® provides greater than 100,000 starts. UltraStart® have the equivalent energy savings and convenience of instant start ballasts but with the long lamp life of a programmed start ballast. UltraStart® T8 L, N and H ballasts exceed 90% efficiency and the NEMA Premium® ballast program minimum efficiency requirements. 4 Compact Fluorescent Lamp (CFL) CFLs are single-ended T4 and T5 lamps that are bent to form a compact shape. Screw-in CFLs have an integral ballast with a screw base for easy replacement of incandescent lamps. GE offers multi-voltage, multi-lamp and multi-entry ballasts for a wide range of CFL plug-in lamps. Multivolt ProLine® CFL ballasts are designed for plug-in lamps so that a ballast will survive over the useful life of approximately 3-to-4 lamp lives. Primarily used for T12 lamps. These ballasts operate lamps at a less efficient 60Hz and typically have efficiencies of 70-80%. Most ballasts consist of a core and coil transformer assembly. Today, magnetic ballasts for 4 foot and 8 foot lamps are typically used only for replacement purposes and are restricted by EPACT to be sold, even in replacement applications, starting in 2009. Multivolt ProLine® CFL Ballast Sign Ballast Sign Ballast (Magnetic Ballast) Designed to operate T12 HO Lamps at 120 volts in cold and damp conditions in sign cabinets. GE eHID, Electronic High Intensity Discharge Ballast (eHID) Electronic HID significantly improves the performance of HID lighting. GE’s UltraMax® eHID ballast operates pulse start and ceramic metal halide lamps. HID Electromagnetic Ballast Kit GE High Intensity Discharge Ballast (HID) HID magnetic ballasts consist of robust core and coil designs that meet or exceed minimum ANSI requirements. These ballasts are typically sold as distributor replacement kits which are pre-wired with a capacitor, ignitor (if applicable) and all necessary mounting hardware and instructions. Each wattage is typically offered in quad (MLT-120/208/240/277 volt), 5-tap (ML5-120/208/240/277/480 volt) or 480 volt (48T) options. UltraMax® eHID Ballast 5 Quick Reference Guides gelighting.com Quick reference ballast selection guide Application Product Page Number Pallet Pack DIY Pack Std Pack Units Per Carton T8 Fluorescent Ballasts UltraMax® Instant-Start Multi-Voltage High-Efficiency DIY Pack Std Pack Units Per Carton 38 38 39 39 40 40 41 41 42 42 43 43 44 44 72260 47548 72256 72267 71715 71718 71721 71724 71726 71729 72268 71722 71730 10 10 10 10 10 10 10 10 10 10 10 10 10 10 71037 71038 10 10 GE-232-277-PS-N 96714 GE232-MVPS-N GE-232-MVPS-XL 29623 GE-332-120-PS-N 29624 GE-332-277-PS-N 29676 GE-332-MVPS-H 96715 GE332-MVPS-N 96721 GE332-MVPS-L 29672 GE-332-MVPS-XL 29625 GE-432-120-PS-N 29627 GE-432-277-PS-N 96716 GE432-MVPS-N 71832 GE432-MVPS-L 29678 GE-432-MVPS-H 30274 30272 97711 97712 10 10 72277 97710 30187 10 ProLine T8 Instant-Start High-Performance 10 10 10 10 10 10 10 10 57 57 24169 24170 10 10 See page 195 for warranty information. 10 60 29632 10 61 96717 10 61 10 62 29651 10 62 29665 10 63 29633 10 63 29634 10 64 29656 10 64 96718 10 65 10 65 29666 10 66 29635 10 66 29650 10 67 96719 10 67 68 10 29657 8 T8 Dimming For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps 80353 B132R120V5 80355 B232SR120V5 80362 B232SR277S50 80356 B232SR277V5 80357 B332SR120V5 80358 B332SR277V5 See page 195 for warranty information. 1 – F32T8 DIM 100 to 5% RS 120 2 – F32T8 DIM 100 to 5% RS 120 2 – F32T8 Switch 100/50% RS 277 2 – F32T8 DIM 100 to 5% RS 277 3 – F32T8 DIM 100 to 5% RS 120 3 – F32T8 DIM 100 to 5% RS 277 69 69 70 70 71 71 10 10 10 10 10 10 7 HID Electromagnetic Ballasts 24161 24162 24163 24164 24165 24166 24167 24168 29630 HID Electronic Ballasts 53 53 54 54 55 55 56 56 60 Compact Fluorescent Ballasts 29671 2 – F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 – F32T8 277V Normal Light .87 BF <10% THD UltraStart® 2 or 1 – F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 or 1 – F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 – F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 – F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 3 – F32T8 120V Normal Light .87 BF <10% THD UltraStart® 3 – F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 – F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 – F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 – F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 – F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 4 – F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 – F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 – F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 4 – F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 4 – F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® Sign Ballasts 10 10 10 10 10 10 10 10 10 10 10 10 10 10 T12 Fluorescent Ballasts 29622 GE-232-MVPS-H ® For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps 23680 GE-132-120-N 1 – F32T8 120V “N”.87 BF ProLine® 23681 GE-132-277-N 1 – F32T8 277V “N”.87 BF ProLine® 23671 GE-232-120-N 2 or 1 – F32T8 120V “N”.87 BF ProLine® 23672 GE-232-277-N 2 or 1 – F32T8 277V “N”.87 BF ProLine® 23673 GE-332-120-N 3 or 2 – F32T8 120V “N”.87 BF ProLine® 23674 GE-332-277-N 3 or 2 – F32T8 277V “N”.87 BF ProLine® 23675 GE-432-120-N 4 or 3 – F32T8 120V “N”.87 BF ProLine® 23676 GE-432-277-N 4 or 3 – F32T8 277V “N”.87 BF ProLine® For 46 – 59W 4 ft – 8 ft Slimline Lamps 23677 GE-259-120-N 2 or 1 – F96T8 120V Normal Light .87 BF ProLine® 23678 GE-259-277-N 2 or 1 – F96T8 277V “N”.87 BF ProLine® GE-232-120-PS-N 29675 51 51 52 29621 10 72270 30275 72274 72276 30296 30309 30270 30303 30310 30271 59 59 For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps 71502 46 46 47 47 48 48 49 49 50 50 2 – F32T8 RS 120V Magnetic Ballast 2 – F32T8 RS 277V Magnetic Ballast UltraStart® T8 Programmed Start GE232-MVPS-L 23954 58 58 T8 PROGRAMMED START BALLASTS 96720 ProLine® T8 Multivolt High Output 120V – 277V 2 or 1 – F96T8HO IS 120 to 277 “N”.87 BF For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps 87125 GEM232T8RS120 87130 GEM232T8RS277 10 45 45 2 or 1 – F32T8 120V “N”.87 BF Residential ProLine® 4 or 3 – F32T8 120V “N”.87 BF Residential ProLine® Electromagnetic T8 Ballasts 71732 ProLine® T8 Multivolt 120V – 277V For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps 72269 GE-132-MV-N 1 – F32T8 120 to 277 “N”.87 BF MV ProLine® 30198 GE-232-MV-H 2 or 1 – F32T8 120 to 277 “H” 1.18 BF MV ProLine® 72273 GE-232-MV-L 2 or 1 – F32T8 120 to 277 “L”.77 BF MV ProLine® 72275 GE-232-MV-N 2 or 1 – F32T8 120 to 277 “N”.87 BF MV ProLine® 30199 GE-332-MV-H 3 or 2 – F32T8 120 to 277 “H” 1.15 BF MV ProLine® 30255 GE-332-MV-L 3 or 2 – F32T8 120 to 277 “L” .77 BF MV ProLine® 30192 GE-332-MV-N 3 or 2 – F32T8 120 to 277 “N”.87 BF MV ProLine® 30219 GE-432-MV-H 4 or 3 – F32T8 120 to 277 “H” 1.15 BF MV ProLine® 30262 GE-432-MV-L 4 or 3 – F32T8 120 to 277 “L” .77 BF MV ProLine® 30193 GE-432-MV-N 4 or 3 – F32T8 120 to 277 “N”.87 BF MV ProLine® For 46 – 59W 4 ft – 8 ft Slimline Lamps 30195 GE-159-MV-N 1 – F96T8 120 to 277 “N”.87 BF MV ProLine® 30194 GE-259-MV-N 2 or 1 – F96T8 120 to 277 “N”.87 BF MV ProLine® For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps 97782 GE232-120-RES 97783 GE432-120-RES T5 Fluorescent Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps 72258 GE132MAX-L/ULTRA 1 – F32T8 120 to 277 “L” .77 BF UltraMax® 72259 GE132MAX-N/ULTRA 1 – F32T8 120 to 277 “N” .87 BF UltraMax® 49775 GE232MAX-H/ULTRA 2 or 1 – F32T8 120 to 277 “H” 1.15 BF UltraMax® 72262 GE232MAX-L/ULTRA 2 or 1 – F32T8 120 to 277 “L” .77 BF UltraMax® 72266 GE232MAX-N/ULTRA 2 or 1 – F32T8 120 to 277 “N” .87 BF UltraMax® 71421 GE232MAX-N+ 2 or 1 – F32T8 120 to 277 “N+” 1.0 BF UltraMax® 71714 GE332MAX-H/ULTRA 3 or 2 – F32T8 120 to 277 “H” 1.18 BF UltraMax® 71717 GE332MAX-L/ULTRA 3 or 2 – F32T8 120 to 277 “L” .77 BF UltraMax® 71719 GE332MAX-N/ULTRA 3 or 2 – F32T8 120 to 277 “N” .87 BF UltraMax® 71422 GE332MAX-N+ 3 or 2 – F32T8 120 to 277 “N+” 1.0 BF UltraMax® 71723 GE432MAX-H/ULTRA 4 or 3 – F32T8 120 to 277 “H” 1.18 BF UltraMax® 71725 GE432MAX-L/ULTRA 4 or 3 – F32T8 120 to 277 “L” .77 BF UltraMax® 71727 GE432MAX-N/ULTRA 4 or 3 – F32T8 120 to 277 “N” .87 BF UltraMax® 71423 GE432MAX-N+ 4 or 3 – F32T8 120 to 277 “N+” 1.0 BF UltraMax® 6, 5, 4 – F32T8 120 to 277 “H” BF UltraMax® 0-10V 100-60% continuous dim 71731 GE632MAX-H90-V60 6, 5, 4 – F32T8 120 to 277 “H” BF UltraMax® 95% 71497 GE632MAX-H90-S60 100/60% step dim For 46 – 59W 4 ft – 8 ft Slimline Lamps 49766 GE159MAX-N/ULTRA 1 – F96T8 120 to 277 “N” .87 BF UltraMax® 49767 GE259MAX-N/ULTRA 2 or 1 – F96T8 120 to 277 “N” .87 BF UltraMax® 6 Application Product Page Number Pallet Pack T8 Fluorescent Ballasts Residential Grade ProLine® T8 120V T8 INSTANT START BALLASTS For 44 – 86W 4 ft – 8 ft HO Lamps 30176 GE-286-HO-MV-N Std Pack Prod Code Description T8 Fluorescent Ballasts Std Pack Prod Code Description Quick Reference Guides gelighting.com Quick reference ballast selection guide (cont.) T5 ELECTRONIC PROGRAMMED START BALLASTS Prod Code New Description (Same) Application 72258 72259 72260 72262 72263 72264 72265 72266 72267 72268 71714 71715 71717 71718 71720 71719 71721 71722 71723 71724 71725 71726 71728 71727 71729 71730 GE132MAX-L/ULTRA GE132MAX-N/ULTRA GE132MAX-N-DIY GE232MAX-L/ULTRA GE232MAX-L-42T GE232MAX-N/AMP GE232MAX-N/CTR GE232MAX-N/ULTRA GE232MAX-N-42T GE232MAX-N-DIY GE332MAX-H/ULTRA GE332MAX-H-42T GE332MAX-L/ULTRA GE332MAX-L-42T GE332MAX-N/CTR GE332MAX-N/ULTRA GE332MAX-N-42T GE332MAX-N-DIY GE432MAX-H/ULTRA GE432MAX-H-42T GE432MAX-L/ULTRA GE432MAX-L-42T GE432MAX-N/CTR GE432MAX-N/ULTRA GE432MAX-N-42T GE432MAX-N-DIY 1- F32T8 120 to 277 “L” .77BF UltraMax® 1- F32T8 120 to 277”N” .87 BF UltraMax® 1- F32T8 120 to 277”N” .87 BF UltraMax® DIY Pack 2 or 1- F32T8 120 to 277 “L” .77 BF UltraMax® 2 or 1- F32T8 120 to 277 “L” .77 BF UltraMax® Pallet Pack 2 or 1- F32T8 120 to 277 “N” .87 BF UltraMax® w/ AMP Connectors 2 or 1- F32T8 120 to 277 “N” .87 BF UltraMax® w/ JST Connectors 2 or 1- F32T8 120 to 277 “N” .87 BF UltraMax® 2 or 1- F32T8 120 to 277 “N” .87 BF UltraMax® Pallet Pack 2 or 1- F32T8 120 to 277 “N” .87 BF UltraMax® DIY Pack 3 or 2- F32T8 120 to 277 “H” 1.18 BF UltraMax® 3 or 2- F32T8 120 to 277 “H” 1.18 BF UltraMax® Pallet Pack 3 or 2- F32T8 120 to 277 “L” .77 BF UltraMax® 3 or 2- F32T8 120 to 277 “L” .77 BF UltraMax® Pallet Pack 3 or 2- F32T8 120 to 277 “N” .87 BF UltraMax® w/ JST Connectors 3 or 2- F32T8 120 to 277 “N” .87 BF UltraMax® 3 or 2- F32T8 120 to 277 “N” .87 BF UltraMax® Pallet Pack 3 or 2- F32T8 120 to 277 “N” .87 BF UltraMax® DIY Pack 4 or 3- F32T8 120 to 277 “H” 1.18 BF UltraMax® 4 or 3- F32T8 120 to 277 “H” 1.18 BF UltraMax® Pallet Pack 4 or 3- F32T8 120 to 277 “L” .77 BF UltraMax® 4 or 3- F32T8 120 to 277 “L” .77 BF UltraMax® Pallet Pack 4 or 3- F32T8 120 to 277 “N” .87 BF UltraMax® w/ JST Connectors 4 or 3- F32T8 120 to 277 “N” .87 BF UltraMax® 4 or 3- F32T8 120 to 277 “N” .87 BF UltraMax® Pallet Pack 4 or 3- F32T8 120 to 277 “N” .87 BF UltraMax® DIY Pack 10 10 4 10 420 10 10 10 420 10 10 420 10 420 10 10 420 4 10 420 10 420 10 10 420 4 39 40 41 41 42 43 43 44 ® ProLine T8 Multivolt 120-277V 72269 72270 72273 72274 72275 72276 72277 GE-132-MV-N GE-132-MV-N-42T GE-232-MV-L GE-232-MV-L-42T GE-232-MV-N GE-232-MV-N-42T GE232MV-N-DIY 1- F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 1- F32T8 120 to 277 “N”.87 BF Multivolt ProLine® Pallet Pack 2 or 1- F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1- F32T8 120 to 277 “L”.77 BF Multivolt ProLine® Pallet Pack 2 or 1- F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1- F32T8 120 to 277 “N”.87 BF Multivolt ProLine® Pallet Pack 2 or 1- F32T8 120 to 277 “N”.87 BF Multivolt ProLine® Pallet Pack DIY Pack 46 47 47 10 420 10 420 10 420 4 77 99654 10 77 78 99656 10 10 T5 High Output Programmed Start For F24 (2 ft), F39 (3 ft), F54 (4 ft), F80 (5 ft) HO T5 Lamps 47534 B224PUNV-COG1C 2 – F24T5HO PRS UNV 50/60 Hz C Can 79 47540 B239PUNV-DOG1C 2 – F39T5HO PRS UNV 50/60 Hz D Can 79 2 or 1 – F54T5HO 120 to 277 UltraStart® PRS High 99651 GE254MVPS90-F Temp F Can 80 99652 47542 B254PUNV-DGE1C 2 – F54T5HO PRS UNV 50/60 Hz D Can 80 72279 GE254MVPS-D 2 or 1 – F54T5HO 120 to 277 UltraStart® PRS D Can 4-1 – F54T5HO 120 to 277 UltraStart® PRS High 99649 GE454MVPS90-E Temp E Can 81 99650 4,3,2, or 1 – F54T5HO 120-277V UltraStart® PRS Can 81 29717 GE454MVPSN1 29726 72280 GE180MVPS-D 1 – F80T5HO 120 to 277 UltraStart® PRS D Can T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length. 10 10 10 10 10 8 12 10 T12 Fluorescent Ballasts T12 ELECTRONIC BALLASTS ProLine® T12 Multivolt 120V – 277V For F20 (2 ft), F30 (3 ft), and F34/F40 (4 ft) T12 Lamps 2 or 1 – F40 or F34T12 Rapid Start 120 to 277 “N” 24107 GE-240-RS-MV-N BF ProLine® T12 2 – F40 or F34T12 Rapid Start 120V “N” BF 97498 GE240RS120 ProLine® T12 1 – F40 or F34T12 Rapid Start Electronic 120V “N” 72110 GE140RS120-DIY BF DIY Pack 3 or 2 – F40 or F34T12 Rapid Start 120 to 277 24109 GE-340-RS-MV-N ProLine® T12 For T12 4 ft – 8 ft Slimline Lamps 24108 GE-260-IS-MV-N 2 or 1 – F96T12 Instant Start 120 to 277 85 24773 10 85 97499 10 86 72110 86 24774 10 87 24776 10 Compact Fluorescent Ballasts 30189 30268 30247 30308 30191 30269 97709 For F14 (2 ft), F21 (3 ft), F28 (4 ft), F35 (5 ft) HE T5 Lamps 2 or 1 – F14-F28T5HE 120 to 277 UltraStart® PRS 99653 GE228MVPSH-A High Light 1.15 BF A Can 2 or 1 – F14-F35T5HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 99655 GE228MVPS-A 47536 B228PUNV-C0G1C 2 – F28T5 PRS UNV 50/60 Hz C Can Sign Ballasts 38 38 UltraMax Instant-Start Multi-Voltage High-Efficiency T5 High Efficiency Programmed Start T12 Fluorescent Ballasts Units Per Carton T5 Fluorescent Ballasts Product Page Number ® 49706 49771 23939 49707 47546 71281 97656 49772 31052 23940 49776 47549 49708 31055 97657 49773 31053 23941 49777 47550 49709 47547 97658 49774 31054 23942 DIY Pack Std Pack Units Per Carton T5 Fluorescent Ballasts T8 Fluorescent Ballasts 2008 T8 Ballast Enhancement New Product Code Cross Reference Existing Application Product Page Number Pallet Pack T8 Fluorescent Ballasts Std Pack Prod Code Description T12 HIGH OUTPUT 80162 80163 B295SR120HP B295SR277HP 72109 GE296HO-MV-N 2 – F96T12HOES RS 120 2 – F96T12HOES RS 277 2 or 1 – F96T12 HO RS 120 to 277 Multivolt ProLine® 88 88 6 6 89 T12 MAGNETIC BALLASTS For 2 ft, Circleline, Preheat T12 Lamps 89712 GEM120TC120DIY 89720 GEM1FC16T9RS120 86227 GEM1FC8T9RS120IP 89717 GEM1FC12T9RS120 80819 GEM220TS120DIY See page 195 for warranty information. 1 – F20T12, F15T8, F1512, F14T8, F18T8, 120V Magnetic Ballast (200H2) 1 – F20T12, F15T8, F15T12, F14T12, 120V Magnetic Ballast (546BTCP) 2 – FC12T9, FC16T9, FC8T9, FC12T9, 120V Magnetic (726VLHWSTCP) 1 – FC8T9, FC6T9 RS 120V Magnetic Ballast (547RSWSTCP) 2 FC12T9 RS 120V Magnetic Ballast (449LRWSTCP) 2– F20T12, F15T8, F15T12, F14T12, 120V Magnetic Ballast (447LRVLHTCP) 90 89711 10 90 89712 4 91 89720 4 91 89722 10 92 89717 92 80819 4 9 HID Electromagnetic Ballasts See page 195 for warranty information. GEM120PH120DIY HID Electronic Ballasts 8 89711 Quick Reference Guides gelighting.com Quick reference ballast selection guide (cont.) Application Product Page Number Pallet Pack DIY Pack Std Pack Units Per Carton T12 Fluorescent Ballasts GEM140HRS120DIY GEM140RS120DIY GEM230RS120DIY 89710 GEM240HRS120DIY 86139 GEM240RS120IP 86124 GEM240RS277IP 1 – F40T12, F40T12, 120V Magnetic Ballast (412LSLHTCP) 1 – F40T12, F30T12, F48/25W, 120V Magnetic Ballast (413CTCP) 2 – F30T12 120V Magnetic Ballast (573LTCP) 2 – F40T12, F40T12, 120V Magnetic Ballast (420LTCP) 2 – F40T12 RS 120V Magnetic Ballast (446LSLHTCP) 2 – F40T12 RS 277V Magnetic Ballast (443LSLHTCP) 2 – F40T12, F40T10, 220V Magnetic Ballast (754LTCP) 96 1 – F96T12 IS 120 Magnetic Ballast (822BRTCP) 1 – F96T12 IS 277 Magnetic Ballast (828BRTCP) 2 – F96T12 IS 120V Magnetic Ballast (806SLHTCP) 2 – F96T12 IS 277V Magnetic Ballast (827SLHTCP) 97 97 98 98 46965 89715 6 6 6 6 99 89718 4 93 89714 4 93 94 89709 80644 4 4 94 89710 4 95 46958 10 95 89713 10 10 86372 2 – F96T12HO, F96T8HO, F72T12HO RS 120V Magnetic Ballast (480SLHTCP) 2 – F96T12HO, F96T8HO, RS 277V Magnetic Ballast (487SLHTCP) 2 – F73T12/BL/HO Suntan 120 Magnetic Ballast 99 100 4 10 FS-2-C FS-4-C FS-5-C FS-25-C FS-12-C Starters for 14, 15 & 20 Watt Flu. Lamps Starters for 30 & 40 Watt Flu. Lamps Starters for 4, 6 & 8 Watt Flu. Lamps Starters for 22 & 25 Watt Flu. Lamps Starters for 32 Watt Circular Flu. Lamps 100 100 100 100 100 24 24 24 24 24 BP-SKT BP SL-SS BP-FM BP-LP Socket Set w/Starter for Bi-Pin Flu. Lamps Socket Set for Bi-Pin Flu. Lamps Socket Set for Slimline Flu. Lamps Face Mount Socket Set for Bi-Pin Flu. Lamps Low Profile Socket Set for Bi-Pin Flu. Lamps 100 100 100 100 100 12 12 12 12 12 T12HO Sign ballast, 4 to 12 ft, 1 to 2 lamps T12HO Sign ballast 6 to 20 ft, 2 to 4 lamps T12HO Sign ballast 12 to 24 ft, 2 to 4 lamps T12HO Sign Ballast 12 to 40 ft, 4 to 6 lamps T12HO Sign Ballast 20 to 40 ft, 4 to 6 lamps T12HO Sign Ballast 24 to 48 ft, 4 to 6 lamps 4 to 12 ft, 1 to 2 lamps 08 to 16 ft, 1 to 4 lamps 16 to 32 ft, 2 to 4 lamps 10 to 24 ft, 1 to 4 lamps 20 to 36 ft, 4 to 6 lamps 20 to 48 ft, 4 to 6 lamps Max 3, 02 to 18 ft, 1 to 6 lamps Max 3, 10 to 48 ft, 1 to 6 lamps Max 3, 12 to 32 ft, 1 to 6 lamps 107 107 108 108 109 109 110 110 111 111 112 112 113 113 114 1 1 1 1 1 1 86164 GEM296HORS120IP 86171 80664 GEM296HORS277IP 493B2 Units Per Carton FLUORESCENT ACCESSORIES For 13 – 42W T4 CFL Lamps 71430 GEC213-MVPS-3W 71434 GEC218-MVPS-3W 71445 GEC226-MVPS-3W 47509 C242UNVSE-IP For 40W Biax® CFL Ballasts 80683 C240PUNVHP-B-IP 80680 C240SI120RH-IP 80681 C240SI277RH-IP 80690 C340SI120RH-IP 80691 C340SI277RH-IP For 5 – 26W Preheat CFL Lamps 87634 GEM1CF579PH277 87533 GEM1CF13PH120 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2 - 42/36/32/26/24 watt CFLUNV side exit 123 71428 71429 71430 10 123 71432 71433 71434 10 124 124 71443 71444 47506 71445 10 10 2 or 1 – FT40W2G11 PS UNV 2 – FT40W/2G11 IS 120 2 – FT40W/2G11 IS 277 3 – FT40W/2G11 IS 120 3 – FT40W/2G11 IS 277 125 125 126 126 127 10 10 10 10 10 1 – CFT579Q9W/G23 Preheat 277 (4205F2P) 1 – CFT/Q13W/GX23 Preheat 120 (4111H2P) 128 128 20 20 2 – CFT/Q13W/GX23 Preheat 277 (4214PBES) 2 – CFQ26W/G24d Preheat 277 (4226PBES) 129 129 10 10 2 – FT36W/2G11 RS 120 (4150P) 2 – FT40W/2G11RS RS 120 (4152P) 130 130 10 10 T12 Fluorescent Ballasts 86341 GEM240RS220IP For T12 4 ft – 8 ft Slimline Lamps 86372 GEM196IS120IP 86381 GEM196IS277IP 86360 GEM296IS120IP 86379 GEM296IS277IP For T12 High Output Lamps Application T5 Fluorescent Ballasts 89709 80644 Description Product Dual Exit/ Page Bottom Exit Bottom and 3-Way Number with Studs side Mounting Compact Fluorescent Ballasts ProLine® CFL Electronic Ballasts For F30, F34/F40 (4 ft) T12 Lamps 89714 Prod Code CFL Magnetic Ballasts For 5 – 26W Preheat CFL Lamps 87655 GEM2CF13PH277 87700 GEM2CF24PH277 For 36 – 40W CFL Lamps 87623 GEM2FT36RS120 87625 GEM2FT40RS120 T8 Fluorescent Ballasts Std Pack Prod Code Description Starters Sign Ballasts 80619 80620 80621 80622 80629 Sockets Compact Fluorescent Ballasts 80623 80624 80625 80627 80628 Sign Ballasts See page 195 for warranty information. See page 195 for warranty information. 11 HID Electromagnetic Ballasts 10 4 2 2 2 2 2 2 2 HID Electronic Ballasts For T12 High Output Lamps 72103 GESB-0412-12-IP 72104 GESB-0620-24-IP 72105 GESB-1224-24-IP 72106 GESB-1240-46-IP 72107 GESB-2040-24-IP 72108 GESB-2448-46-IP 88921 USB-0412-12-IP 88931 USB-0816-14-IP 88934 USB-1632-24-IP 88936 USB-1024-14-IP 88939 USB-2036-46-IP 88940 USB-2048-46-IP 88918 USB-0218-16-IP 88919 USB-1048-16-IP 88920 USB-1232-16-IP Quick Reference Guides gelighting.com Quick reference ballast selection guide (cont.) Prod Code Description Application Product Page Number ANSI Lamp Type Circuit Type Units Per Carton For 20 – 150W Pulse Start HID Lamps 87490 GEMH20-MLF-120 87501 GEMH39-MSF-120 GEMH50-MSF-120 87531 GEMH70-MSF-120 87546 GEMH70-SLJ-MV 87561 GEMH100-SLJ-MV 87576 GEMH150-SLJ-MV For 250W – 400W Pulse Start HID Lamps GE-MH-250-400-MA 89646 GEMH250-400M-V50 1 – 250 to 400W UltraMax® HID Dimming 208-277 50-60Hz M156 M130 Electronic Electronic 10 10 136 Electronic 10 Electronic 10 137 M148, M110, C148 M98, M143, M139, C143, C139 M139, C139, M98, M143, C143 Electronic 10 137 M90, M140, C140 Electronic 10 138 M142, M102, C142 Electronic 10 136 139 139 M155, M153, M138, M135, M132, M131, M154 M155, M154, M153, M138, M135, M132, M131 Electronic 1 Electronic 1 HID Electromagnetic Ballasts Metal Halide For 20 – 175W Metal Halide HID Lamps M110 HX-HPF 6 M98 M98 HX-HPF HX-HPF 6 6 145 146 M92, M90, M140 M92, M90, 40 HX-HPF HX-HPF 6 6 146 147 M142, M102 M142, M102, M107 HX-HPF HX-HPF 6 6 147 M57, H39, M109 CWA 6 148 M57, M107, H39 CWA 6 149 M58, H37 CWA 6 149 M58, H37 CWA 6 150 M58, H37 CWA 3 150 M59, H33 CWA 3 151 151 152 M59, H33 M59, H33 M47, H36 CWA CWA CWA 3 3 2 152 M47, H36 CWA 2 153 153 M47, H36 M48 CWA CWA 2 2 154 M48 CWA 2 155 155 M153, M137 M152, M137 CWA CWA 6 6 156 156 M153, M138 M153, M138 CWA CWA 3 3 157 157 M154, M132 M154, M132 CWA CWA 3 3 158 M154, M132 CWA 3 158 159 M131 M155, M135 CWA CWA 3 3 159 160 M155, M135 M149 CWA CWA 3 2 160 M149 CWA 2 161 M141 CWA 2 161 M141 CWA 2 162 S68 HX-HPF 6 162 163 S62 S62 HX-HPF HX-HPF 6 6 163 164 S54 S54 HX-HPF HX-HPF 6 6 164 165 S55 S55 HX-HPF HX-HPF 6 6 166 S50 CWA 3 166 S50 CWA 3 167 S51 CWA 3 167 S51 CWA 3 168 168 S51 S52 CWA CWA 3 2 169 S52 CWA 2 169 S52 CWA 2 HID Electromagnetic Ballasts Pulse Start For 175 – 1000W Pulse Start Metal Halide HID Lamps 1 – 175W PS M137 or M152 Quad 86885 GEP175MLTAC3-5 (120/208/240/277V) 86876 GEP17548TAC3-5 1 – 175W PS M137 or M152 480 1 – 250W PS M138 or M153 Quad 86935 GEP250MLTAC4-5 (120/208/240/277V) 86926 GEP25048TAC4-5 1 – 250W PS M138 or M153 480 1 – 320W PS M132 or 154 Quad 86959 GEP320MLTAC4-5 (120/208/240/277V) 86952 GEP32048TAC4-5 1 – 320W PS M132 or M154 480 1 – 320W PS M132 or M154 TRI-Voltage 86968 GEP320TRIAC4-5 120 277 347 1 – 350W PS M131 Quad 86984 GEP350MLTAC4-5 (120/208/240/277V) 86999 GEP40048TAC4-5 1 – 400W PS M135 or M155 480 1 – 400W PS M135 or M155 Quad 87008 GEP400MLTAC4-5 (120/208/240/277V) 46936 GEP75048TAC5-5 1 – 750W PS M149 480 1 – 750W PS M149 Quad 46934 GEP750MLTAC5-5 (120/208/240/277V) 1 – 1000W PS M141 Quad 72281 GEP1000MLTAC5-5 (120/208/240/277V) 1 – 1000W PS M141 5-Tap 72282 GEP1000ML5AC5-5 (120/208/240/277/480V) High-Pressure Sodium For 50 – 150W High Pressure Sodium HID Lamps 1 – 50W HPS S68 Quad 87152 GES50MLTLC3D-5 (120/208/240/277V) 1 – 70W HPS S62 Quad 86587 GES70MLTLC3D-5 (120/208/240/277V) 86456 GES7048TLC3D-5 1 – 70W HPS S62 480V 1 – 100W HPS S54 Quad 87074 GES100MLTLC3D-5 (120/208/240/277V) 87068 GES10048TLC3D-5 1 – 100W HPS S54 480V 1 – 150W HPS S55 Quad 87094 GES150MLTLC3D-5 (120/208/240/277V) 87087 GES15048TLC3D-5 1 – 150W HPS S55 480V For 250 – 1000W High Pressure Sodium HID Lamps 1 – 250W HPS S50 5-Tap 87214 GES250ML5AC4-5 (120/208/240/277/480V) 1 – 250W HPS S50 Quad 87121 GES250MLTAC4-5 (120/208/240/277V) 1 – 400W HPS S51 5-Tap 87215 GES400ML5AC4-5 (120/208/240/277/480V) 1 – 400W HPS S51 Quad 87164 GES400MLTAC4-5 (120/208/240/277V) 1 – 400W HPS S51 480V in smaller 87198 GES40048TAC4-5 frame 87048 GES100048TAC5-5 1 – 1000W HPS S52 480V 1 – 1000W HPS S52 5-Tap 87218 GES1000ML5AC5-5 (120/208/240/277/480V) 1 – 1000W HPS S52 Quad 87056 GES1000MLTAC5-5 (120/208/240/277V) See page 195 for warranty information. 13 HID Electromagnetic Ballasts See page 195 for warranty information. Units Per Carton HID Electronic Ballasts 144 145 Circuit Type Compact Fluorescent Ballasts 12 144 ANSI Lamp Type Sign Ballasts 1 – 50W MH M110 or M148 Quad 86824 GEM50MLTLC3D-5 (120/208/240/277V) 1 – 70W MH M98 or M143 Quad 86847 GEM70MLTLC3D-5 (120/208/240/277V) 86839 GEM7048TLC3D-5 1 – 70W MH M98 or M143 480 1 – 100W MH M90 or M140 Quad 86675 GEM100MLTLC3D-5 (120/208/240/277V) 86667 GEM10048TLC3D-5 1 – 100W MH M90 or M140 480 1 – 150W MH M102 or M142 Quad 86718 GEM150MLTLC3D-5 (120/208/240/277V) 86711 GEM15048TLC3D-5 1 – 150W MH M102 or M142 480 1 – 175W MH M57 or H39 5-Tap 87210 GEM175ML5AC3-5 (120/208/240/277/480V) 1 – 175W MH M57 or H39 Quad 86741 GEM175MLTAC3-5 (120/208/240/277V) For 250 – 1500W Metal Halide HID Lamps 1 – 250W MH M58 or H37 5-Tap 87211 GEM250ML5AC3-5 (120/208/240/277/480V) 1 – 250W MH M58 or H37 Quad 86765 GEM250MLTAC3-5 (120/208/240/277V) 1 – 250W MH M58 or H37 5-Tap 87212 GEM250ML5AC4-5 (120/208/240/277/480V) 1 – 400W MH M59 or H33 5-Tap 72300 GEM400ML5AA4-5 (120/208/240/277/480V) Al C&C 1 – 400W MH M59 or H33 Quad 72149 GEM400MLTAA4-5 (120/208/240/277V) Al C&C 86803 GEM40048TAC4-5 1 – 400W MH M59 or H33 480 86650 GEM100048TAC5-5 1 – 1000W MH M47 or H36 480 1 – 1000W MH M47 or H36 5-Tap 87213 GEM1000ML5AA5-5 (120/208/240/277/480V) 1 – 1000W MH M47 or H36 Quad 86655 GEM1000MLTAA5-5 (120/208/240/277V) 86693 GEM150048TAC5-5 1 – 1500W MH M48 480 1 – 1500W MH M48 Quad 86698 GEM1500MLTAC5-5 (120/208/240/277V) Product Page Number T12 Fluorescent Ballasts 29377 1 – 250 to 400W UltraMax® HID Electronic 208-277 50-60Hz 135 135 Application T5 Fluorescent Ballasts 87516 1 – 20W M156 120V Electronic HID 1 – 39W M130 120V Electronic HID 1 – 50W M110 M/C148 120V Electronic HID 1 – 70W M98 M/C143 120V Electronic HID 1 – 70W M98 M/C143 120V-277V Electronic HID 1 – 100W M90 M/C140 120V-277V Electronic HID 1 – 150W M102 M/C142 120V-277V Electronic HID Description T8 Fluorescent Ballasts HID Electronic Ballasts Prod Code Quick Reference Guides gelighting.com Quick reference ballast selection guide (cont.) Prod Code Description Application Product Page Number ANSI Lamp Type Circuit Type Units Per Carton 71701 GEM175ML5AC3-55 GEM250ML5AC3-55 71703 GEM400ML5AC4-55 71704 GEM1000ML5AC4-55 71705 GES100MLTLC3D-55 71706 GES250ML5AC4-55 GES400ML5AC4-55 86578 11210506CTC000C 86574 11210239CTC000I 86563 1110245SCTC000I 86564 1110246CTC000C 42670 1110-247SC-TC 80728 1111-247SCTC000I 1 – 70W M85 120/277 Enclosed & Potted 1 – 70W M98 120/277 Enclosed & Potted 1 – 100W M90 120/277 Enclosed & Potted 1 – 175W M57 120/277 Enclosed & Potted 1 – 250W M58 120/277 Enclosed & Potted 1 – 400W M59 120/277 Enclosed & Potted F-can 1 – 400W M59 120/277 Enclosed & Potted Circuit Type Units Per Carton HID ACCESSORIES Replacement Capacitors 170 M57 Mogul Base Elliptical Lamp CWA 1 170 M58 Mogul Base Elliptical Lamp CWA 1 171 M59 Mogul Base Elliptical Lamp CWA 1 171 M47 Mogul Base Elliptical Lamp CWA 1 172 S54 Medium Base Elliptical Lamp HX-HPF 1 172 M50 Mogul Base ED18 Lamp CWA 1 173 S51 Mogul Base ED18 Lamp CWA 174 M85 174 88980 005-1184-MF 88982 005-1185-MF 89007 89077 005-1422-MF 005-2779-MF 89083 005-3160-MF 20 10.0 MFD 400V 90C 2.4 MEG 1.50 oval 2.7 ht 15.0 MFD 400V 90C 1.6 MEG 1.75 oval 2.7 ht 48.0 MFD 300V 90C 0.6 MEG 1.75 oval 3.9 ht 24.0 MFD 480V 90C 1.75 oval 3.9 ht 24.0 MFD 360V 90C 1.0 MEG 1.75 oval 3.1 ht 179 20 179 20 179 179 20 20 179 20 179 20 179 20 179 10 179 179 100 10 179 179 50 50 Replacement Ignitors for Pulse Start lamps – (MH and HPS) 86864 MH100-3A 86635 HPS150-3A 86641 HPS400-3A Ignitor for MH 30 50 70 100 Ignitor HPS 150 watts or less except 150W-S56 Ignitor HPS 200-400 watts & 150W S56 Other Accessories 1 47621 86467 000-8724 001-2009 HX-HPF 4 86468 86624 004-9177 2BMB1000C M98 HX-HPF 4 175 M90 HX-HPF 4 175 M57, H39 CWA 2 176 M58, H37 CWA 2 176 M59, H33 CWA 2 177 M59, H33 CWA 4 178 S62 R-HPF, R-NPF 6 178 179 S62 S55 HX-HPF R-NPF 4 6 HIDP Adjustable Mounting Bracket Hardware Kit Splice Box Adjustable Mounting Bracket For 4" HID HID Parts E&P Mounting Bracket Sign Ballasts 11210277CTC000C ANSI Lamp Type HID Electromagnetic Ballasts Enclosed and Potted Metal Halide 86576 Product Page Number T12 Fluorescent Ballasts 71707 Application T5 Fluorescent Ballasts 71702 1 – 175W MH M57 or H39 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) 1 – 250W MH M58 or H37 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) 1 – 400W MH M59 or H33 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) 1 – 1000W MH M47 or H36 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) 1 – 100W HPS S54 Quad (120/208/240/277V) Lamp & Ballast Kit (-55) 1 – 250W HPS S50 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) 1 – 400W HPS S51 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) Description T8 Fluorescent Ballasts HID Electromagnetic Ballasts High Intensity Discharge Lamp Ballast Kits Prod Code F-Can and Post Mount High Pressure Sodium 1233142U000I 86596 86606 12210237CTC000I 1233154U000I 1 – 70W S62 120 Reactor-NPF 1 – 70W S62 120/277 E and P F-Can built-in starter 1 – 150W S55 120 Reactor-NPF Compact Fluorescent Ballasts 86605 HID Electronic Ballasts See page 195 for warranty information. See page 195 for warranty information. 15 HID Electromagnetic Ballasts 14 Quick Reference Guides gelighting.com Quick reference lamp to ballast selection guide Linear Fluorescent Lamps F13T5 F14T12 F14T5/HE 120-277 120-277 120 120-277 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start 71430 71427 89712 47536 GEC213-MVPS-3W GEC213-MVPS-XX GEM120TC120DIY B228PUNV-C0G1C 2 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 2 2 2 1 120-277 120-277 120-277 120-277 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start 99653 71430 71429 47536 GE228MVPSH-A GEC213-MVPS-3W GEC213-MVPS-XX B228PUNV-C0G1C 1 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 1 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 2 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 2 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 1 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 1 1 120-277 Electronic - Program / Rapid Start 120 Magnetic - Rapid Start 99653 89711 GE228MVPSH-A GEM120PH120DIY 80819 89711 89712 GEM220TS120DIY GEM120PH120DIY GEM120TC120DIY F15T8 2 1 1 120 120 120 Magnetic - Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start 80819 89711 89712 GEM220TS120DIY GEM120PH120DIY GEM120TC120DIY 4 120-277 3 120-277 3 3 120-277 2 120-277 2 120-277 2 F17T8 16 120-277 120-277 1 120-277 4 120-277 4 120-277 4 4 4 4 4 4 4 4 4 4 4 4 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 120 120 120 3 120-277 3 120-277 3 120-277 77 77 123 123 78 77 77 77 77 77 77 90 92 90 90 92 90 90 3 3 3 3 3 3 3 120-277 120-277 120-277 120-277 120-277 120-277 120-277 3 120-277 3 120-277 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 277 120 120 120 120 120 2 120-277 2 120-277 71423 GE432MAX-N+ 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 44 71421 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 2 2 2 2 2 2 2 2 2 2 71422 GE332MAX-N+ 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 42 2 GE332MAX-N+ ® 42 2 120-277 71421 GE232MAX-N+ ® 40 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 44 71725 GE432MAX-L/ULTRA 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 277 277 120 120 120 120 120 120 1 120-277 1 1 120-277 120-277 1 120-277 71423 GE432MAX-N+ 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 44 71422 GE332MAX-N+ 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 42 GE332MAX-N+ ® 42 ® 71422 71422 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax® ® 71727 30219 30262 30193 30193 29678 96716 23676 29627 23675 29625 97783 GE432MAX-N/ULTRA GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-MVPS-H GE432-MVPS-N GE-432-277-N GE-432-277-PS-N GE-432-120-N GE-432-120-PS-N GE432-120-RES 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B 71714 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® ® 43 44 49 50 50 50 68 67 56 66 62 66 58 41 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax 41 71719 GE332MAX-N/ULTRA 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax® 42 See page 195 for warranty information. F17T8 (cont) 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start See page 195 for warranty information. 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 48 48 49 64 65 64 65 30199 30255 30192 29676 96721 96715 29672 GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-MVPS-H GE332-MVPS-L GE332-MVPS-N GE-332-MVPS-XL 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 71725 GE432MAX-L/ULTRA 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax® 43 71727 30219 30262 30193 30193 29678 96716 23674 29624 23676 29627 23673 29623 23675 29625 97783 GE432MAX-N/ULTRA GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-MVPS-H GE432-MVPS-N GE-332-277-N GE-332-277-PS-N GE-432-277-N GE-432-277-PS-N GE-332-120-N GE-332-120-PS-N GE-432-120-N GE-432-120-PS-N GE432-120-RES 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax® 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B 44 49 50 50 50 68 67 55 63 56 66 55 63 56 66 58 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 72262 ® GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax ® 72266 30198 30198 72273 72275 72275 29675 96720 96714 29671 GE232MAX-N/ULTRA GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N GE-232-MV-N GE-232-MVPS-H GE232-MVPS-L GE232-MVPS-N GE-232-MVPS-XL 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 71714 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® ® 43 39 39 40 46 46 47 47 47 62 61 61 62 41 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax 71719 30199 30255 30192 29676 96721 96715 29672 23672 29622 23674 29624 87130 23671 29621 97782 23673 23673 29623 GE332MAX-N/ULTRA GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-MVPS-H GE332-MVPS-L GE332-MVPS-N GE-332-MVPS-XL GE-232-277-N GE-232-277-PS-N GE-332-277-N GE-332-277-PS-N GEM232T8RS277 GE-232-120-N GE-232-120-PS-N GE232-120-RES GE-332-120-N GE-332-120-N GE-332-120-PS-N 72258 GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax® 38 72259 72269 GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax® GE-132-MV-N 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 38 46 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax® 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 2 - F32T8 RS 277V Magnetic Ballast (M232SR277C) 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF Residential ProLine® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 41 42 48 48 49 64 65 64 65 54 60 55 63 59 54 60 58 55 55 63 17 HID Electromagnetic Ballasts Magnetic - Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Linear Fluorescent Lamps HID Electronic Ballasts 120 120 120 123 44 90 78 Prod Code Page No Fluorescent Ballast Long Description Compact Fluorescent Ballasts 2 1 1 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 1 - F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (546BTCP) 2 - F28T5 PRS UNV 50/60 Hz 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 - F28T5 PRS UNV 50/60 Hz 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 1 - F20T12 F15T8 F1512 120V Magnetic Ballast (200H2) 2- F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (447LRVLHTCP) 1 - F20T12 F15T8 F1512 120V Magnetic Ballast (200H2) 1 - F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (546BTCP) 2- F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (447LRVLHTCP) 1 - F20T12 F15T8 F1512 120V Magnetic Ballast (200H2) 1 - F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (546BTCP) Ballast Product Code Ballast Description Sign Ballasts F15T12 Fluorescent Ballast Long Description # of Lamp Type Lamps Voltage Fluorescent Ballast Type T12 Fluorescent Ballasts F14T8 2 2 1 2 Prod Code Page No T5 Fluorescent Ballasts F14T5/WM Ballast Product Code Ballast Description T8 Fluorescent Ballasts # of Lamp Type Lamps Voltage Fluorescent Ballast Type Quick Reference Guides gelighting.com Quick reference lamp to ballast selection guide (cont.) Ballast Product Code Ballast Description Prod Code Page No Fluorescent Ballast Long Description Linear Fluorescent Lamps F18T8 F21T5/HE GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax 71723 30198 30198 72273 72275 72275 29675 96720 GE232MAX-N/ULTRA GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N GE-232-MV-N GE-232-MVPS-H GE232-MVPS-L 39 4 43 46 46 47 47 47 62 61 4 4 4 99655 GE228MVPS-A 1 2 2 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start 99653 47534 47540 GE228MVPSH-A B224PUNV-COG1C B239PUNV-DOG1C 2 120-277 Electronic - Program / Rapid Start 71445 GEC226-MVPS-3W 2 1 1 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start 71444 47534 47540 GEC226-MVPS-XX B224PUNV-COG1C B239PUNV-DOG1C 71423 GE432MAX-N+ 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 44 GE332MAX-N+ ® 42 ® 44 120-277 120-277 277 277 277 120 120 120 120 120 120-277 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Magnetic - Rapid Start Electronic - Program / Rapid Start 96714 29671 23681 23672 29622 23680 23671 29621 97782 89711 24107 GE232-MVPS-N GE-232-MVPS-XL GE-132-277-N GE-232-277-N GE-232-277-PS-N GE-132-120-N GE-232-120-N GE-232-120-PS-N GE232-120-RES GEM120PH120DIY GE-240-RS-MV-N 2 1 1 1 2 120 120-277 120 120 120-277 Magnetic - Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start 80819 24107 89711 89712 47536 GEM220TS120DIY GE-240-RS-MV-N GEM120PH120DIY GEM120TC120DIY B228PUNV-C0G1C 2 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 2 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 2 1 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start 99653 47536 GE228MVPSH-A B228PUNV-C0G1C 1 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 1 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 1 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 2 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 2 3 3 2 2 1 4 120-277 Electronic - Program / Rapid Start 99653 71422 71423 GE228MVPSH-A GE432MAX-N+ 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 92 85 90 90 78 3 3 3 3 3 3 3 2 F25T12 (cont) 2 2 77 2 77 2 77 2 2 2 2 2 2 77 1 77 1 77 78 77 1 77 77 1 77 79 79 1 1 1 1 1 124 4 4 124 79 79 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 71422 GE332MAX-N+ 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 42 71421 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 3 61 62 53 54 60 53 54 60 58 90 85 71421 71723 3 43 3 3 3 F25T8 2 2 1 4 4 4 18 See page 195 for warranty information. See page 195 for warranty information. 71725 GE432MAX-L/ULTRA 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax® 43 71727 23676 23675 GE432MAX-N/ULTRA 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax® GE-432-277-N 4 or 3 - F32T8 277V “N”.87 BF ProLine® GE-432-120-N 4 or 3 - F32T8 120V “N”.87 BF ProLine® 44 56 56 71714 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 41 71717 ® GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax 41 ® 71719 GE332MAX-N/ULTRA 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax 42 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 43 71725 GE432MAX-L/ULTRA 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax® 43 ® 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax 3 or 2 - F32T8 277V “N”.87 BF ProLine® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 44 55 56 55 56 71727 23674 23676 23673 23675 GE432MAX-N/ULTRA GE-332-277-N GE-432-277-N GE-332-120-N GE-432-120-N 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 71725 GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax® 43 ® 72266 GE232MAX-N/ULTRA 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax 40 71714 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 41 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax® 41 ® 71719 23672 23674 23671 97498 23673 GE332MAX-N/ULTRA GE-232-277-N GE-332-277-N GE-232-120-N GE240RS120 GE-332-120-N 72258 GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax® 72259 GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax® 49775 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax 2 or 1 - F32T8 277V “N”.87 BF ProLine® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 F40 or F34T12 Rapid Start Electronic 120V “N” BF 3 or 2 - F32T8 120V “N”.87 BF ProLine® 42 54 55 54 85 55 38 38 ® GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax ® 39 43 71725 GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax 72266 23681 23672 23680 23671 GE232MAX-N/ULTRA GE-132-277-N GE-232-277-N GE-132-120-N GE-232-120-N 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax® 1 - F32T8 277V “N”.87 BF ProLine® 2 or 1 - F32T8 277V “N”.87 BF ProLine® 1 - F32T8 120V “N”.87 BF ProLine® 2 or 1 - F32T8 120V “N”.87 BF ProLine® 40 53 54 53 54 71423 71832 GE432MAX-N+ GE432-MVPS-L 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 44 67 71422 GE332MAX-N+ 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 42 71423 71832 GE432MAX-N+ GE432-MVPS-L 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 44 67 71421 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 71422 GE332MAX-N+ ® 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 42 71421 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 43 71725 71727 GE432MAX-L/ULTRA ® 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax ® GE432MAX-N/ULTRA 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax 43 44 19 HID Electromagnetic Ballasts 120-277 Electronic - Program / Rapid Start 1 1 1 1 1 1 1 1 1 1 2 3 Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start 277 Electronic - Standard Instant Start 120 Electronic - Standard Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start 277 Electronic - Standard Instant Start 277 Electronic - Standard Instant Start 120 Electronic - Standard Instant Start 120 Electronic - Standard Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start 277 Electronic - Standard Instant Start 277 Electronic - Standard Instant Start 120 Electronic - Standard Instant Start 120 Electronic - Program / Rapid Start 120 Electronic - Standard Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start 277 Electronic - Standard Instant Start 277 Electronic - Standard Instant Start 120 Electronic - Standard Instant Start 120 Electronic - Standard Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start 120-277 Electronic - Program / Rapid Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start 120-277 Electronic - Program / Rapid Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start HID Electronic Ballasts 1 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 1 - F32T8 277V “N”.87 BF ProLine® 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 1 - F32T8 120V “N”.87 BF ProLine® 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF Residential ProLine® 1 - F20T12 F15T8 F1512 120V Magnetic Ballast (200H2) 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 2- F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (447LRVLHTCP) 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 1 - F20T12 F15T8 F1512 120V Magnetic Ballast (200H2) 1 - F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (546BTCP) 2 - F28T5 PRS UNV 50/60 Hz 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 15 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 - F28T5 PRS UNV 50/60 Hz 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 14 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 - F24T5HO PRS UNV 50/60 Hz 2 - F39T5HO PRS UNV 50/60 Hz 2 - CFQ26W, FT24 or 1-42W, CFTR32 3-Way Mounting Kit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2 - F24T5HO PRS UNV 50/60 Hz 2 - F39T5HO PRS UNV 50/60 Hz 4 F25T12 72262 Compact Fluorescent Ballasts F24T5/HO 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 Linear Fluorescent Lamps ® Sign Ballasts F21T5/WM 1 1 1 1 1 1 1 1 Prod Code Page No Fluorescent Ballast Long Description T12 Fluorescent Ballasts F20T12 120-277 Ballast Product Code Ballast Description T5 Fluorescent Ballasts F17T8 (cont) 1 Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start # of Lamp Type Lamps Voltage Fluorescent Ballast Type T8 Fluorescent Ballasts # of Lamp Type Lamps Voltage Fluorescent Ballast Type Quick Reference Guides gelighting.com Quick reference lamp to ballast selection guide (cont.) Linear Fluorescent Lamps 3 120-277 3 120-277 3 3 3 3 3 3 3 3 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 3 120-277 3 120-277 2 120-277 2 2 2 2 2 2 2 2 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 2 2 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start Electronic - High Efficiency 120-277 Multivolt Instant Start 120-277 Electronic - Multivolt Instant Start 120-277 Electronic - Multivolt Instant Start 120-277 Electronic - Multivolt Instant Start 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start 277 Electronic - Dimming 277 Electronic - Dimming 2 2 2 2 2 2 2 2 2 2 2 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 41 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax® 41 71719 30199 30255 30192 29676 96721 96715 29672 GE332MAX-N/ULTRA GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-MVPS-H GE332-MVPS-L GE332-MVPS-N GE-332-MVPS-XL 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 71725 GE432MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax® 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax® ® 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B 42 48 48 49 64 65 64 65 43 43 71727 30219 30262 30193 30193 29678 96716 23674 29624 23676 29627 23673 29623 23675 29625 97783 GE432MAX-N/ULTRA GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-MVPS-H GE432-MVPS-N GE-332-277-N GE-332-277-PS-N GE-432-277-N GE-432-277-PS-N GE-332-120-N GE-332-120-PS-N GE-432-120-N GE-432-120-PS-N GE432-120-RES 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 72262 GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax® 39 72266 30198 30198 72273 72275 72275 29675 96720 GE232MAX-N/ULTRA GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N GE-232-MV-N GE-232-MVPS-H GE232-MVPS-L 96714 29671 GE232-MVPS-N GE-232-MVPS-XL 71714 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD F25T8 (cont) 44 49 50 50 50 68 67 55 63 56 66 55 63 56 66 58 40 46 46 47 47 47 62 61 F28T5 F28T5/HE 2 2 2 2 2 2 2 2 2 2 277 277 277 277 277 120 120 120 120 120 1 120-277 1 1 1 1 1 1 1 1 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start 1 120-277 1 1 120-277 120-277 1 120-277 1 1 1 1 1 1 1 1 1 1 1 2 120-277 120-277 277 277 277 120 120 120 120 120 120 120-277 72258 GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax® 38 72259 72269 GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax® GE-132-MV-N 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 38 46 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 ® 72262 GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax 72266 30198 30198 72273 72275 72275 29675 96720 GE232MAX-N/ULTRA GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N GE-232-MV-N GE-232-MVPS-H GE232-MVPS-L Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Dimming Electronic - Dimming Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start 96714 29671 23681 23672 29622 80353 80353 23680 23671 29621 97782 47536 GE232-MVPS-N GE-232-MVPS-XL GE-132-277-N GE-232-277-N GE-232-277-PS-N B132R120V5 B132R120V5 GE-132-120-N GE-232-120-N GE-232-120-PS-N GE232-120-RES B228PUNV-C0G1C 2 1 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start 99653 47536 GE228MVPSH-A B228PUNV-C0G1C 1 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 2 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 2 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 1 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 1 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 2 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 2 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 1 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 41 1 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax® 41 2 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 71719 30199 30255 30192 29676 96721 96715 29672 80362 80362 GE332MAX-N/ULTRA GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-MVPS-H GE332-MVPS-L GE332-MVPS-N GE-332-MVPS-XL B232SR277S50 B232SR277S50 2 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 1 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 1 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax® 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 2 - F32T8 Switch 100/50% RS 277 2 - F32T8 Switch 100/50% RS 277 42 48 48 49 64 65 64 65 70 70 See page 195 for warranty information. F28T5/WM See page 195 for warranty information. 54 60 55 63 59 54 60 58 55 63 GE-232-277-N GE-232-277-PS-N GE-332-277-N GE-332-277-PS-N GEM232T8RS277 GE-232-120-N GE-232-120-PS-N GE232-120-RES GE-332-120-N GE-332-120-PS-N 61 62 F28T5/HL 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 2 - F32T8 RS 277V Magnetic Ballast (M232SR277C) 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF Residential ProLine® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 23672 29622 23674 29624 87130 23671 29621 97782 23673 29623 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 1 - F32T8 277V “N”.87 BF ProLine® 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 1 - F32T8 DIM 100 to 5% RS 120 1 - F32T8 DIM 100 to 5% RS 120 1 - F32T8 120V “N”.87 BF ProLine® 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF Residential ProLine® 2 - F28T5 PRS UNV 50/60 Hz 8 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 - F28T5 PRS UNV 50/60 Hz 7 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 39 40 46 46 47 47 47 62 61 61 62 53 54 60 69 69 53 54 60 58 78 77 78 77 77 77 77 77 77 77 77 77 77 77 77 77 21 HID Electromagnetic Ballasts 120-277 71714 Linear Fluorescent Lamps HID Electronic Ballasts 2 49 50 50 50 68 67 56 66 56 66 58 GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-MVPS-H GE432-MVPS-N GE-432-277-N GE-432-277-PS-N GE-432-120-N GE-432-120-PS-N GE432-120-RES Prod Code Page No Fluorescent Ballast Long Description Compact Fluorescent Ballasts 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 277 120 120 120 120 120 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B 30219 30262 30193 30193 29678 96716 23676 29627 23675 29625 97783 Ballast Product Code Ballast Description Sign Ballasts 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 20 Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Fluorescent Ballast Long Description # of Lamp Type Lamps Voltage Fluorescent Ballast Type T12 Fluorescent Ballasts 120-277 120-277 120-277 120-277 120-277 120-277 277 277 120 120 120 Prod Code Page No T5 Fluorescent Ballasts F25T8 (cont) 4 4 4 4 4 4 4 4 4 4 4 Ballast Product Code Ballast Description T8 Fluorescent Ballasts # of Lamp Type Lamps Voltage Fluorescent Ballast Type Quick Reference Guides gelighting.com Quick reference lamp to ballast selection guide (cont.) Ballast Product Code Ballast Description Prod Code Page No Fluorescent Ballast Long Description Linear Fluorescent Lamps 120-277 120-277 3 120-277 3 3 120-277 120-277 2 120-277 2 120-277 1 120-277 4 120-277 120-277 3 120-277 3 3 3 3 3 3 3 3 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 3 120-277 3 120-277 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 277 120 120 120 120 120 2 120-277 2 120-277 2 2 2 2 2 22 120-277 120-277 120-277 120-277 120-277 71422 GE332MAX-N+ 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 42 71423 71832 GE432MAX-N+ GE432-MVPS-L 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 44 67 71421 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 71422 GE332MAX-N+ 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 42 71421 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 43 ® 71725 GE432MAX-L/ULTRA 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax 43 71727 30219 30262 30193 30193 29678 96716 23676 29627 23675 29625 97783 GE432MAX-N/ULTRA GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-MVPS-H GE432-MVPS-N GE-432-277-N GE-432-277-PS-N GE-432-120-N GE-432-120-PS-N GE432-120-RES 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax® 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B 44 49 50 50 50 68 67 56 66 56 66 58 71714 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 41 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax® 41 71719 30199 30255 30192 29676 96721 96715 29672 GE332MAX-N/ULTRA GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-MVPS-H GE332-MVPS-L GE332-MVPS-N GE-332-MVPS-XL 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 71725 GE432MAX-L/ULTRA 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax® 43 71727 30219 30262 30193 30193 29678 96716 23674 29624 23676 29627 23673 29623 23675 29625 97783 GE432MAX-N/ULTRA GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-MVPS-H GE432-MVPS-N GE-332-277-N GE-332-277-PS-N GE-432-277-N GE-432-277-PS-N GE-332-120-N GE-332-120-PS-N GE-432-120-N GE-432-120-PS-N GE432-120-RES 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax® 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B 44 49 50 50 50 68 67 55 63 56 66 55 63 56 66 58 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 72262 GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax® 39 72266 30198 30198 72273 72275 GE232MAX-N/ULTRA GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax® 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD ® 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® F28T8 (cont) 42 48 48 49 64 65 64 65 43 40 46 46 47 47 See page 195 for warranty information. F30T12 F30T12/WM F32T8 2 2 2 2 2 120-277 120-277 120-277 120-277 120-277 2 120-277 2 120-277 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 277 120 120 120 120 120 1 120-277 1 1 120-277 120-277 1 120-277 1 120-277 1 1 1 1 1 1 1 1 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 1 1 1 1 1 1 1 1 1 3 2 2 2 2 1 1 1 1 2 3 2 2 1 120-277 120-277 277 277 277 120 120 120 120 120-277 120-277 120-277 120 120 120-277 120 120 120 120 120-277 120-277 120-277 120-277 4 4 3 Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency 120-277 Multivolt Instant Start 120-277 Electronic - Program / Rapid Start Electronic - High Efficiency 120-277 Multivolt Instant Start See page 195 for warranty information. 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 47 62 61 61 62 72275 29675 96720 96714 29671 GE-232-MV-N GE-232-MVPS-H GE232-MVPS-L GE232-MVPS-N GE-232-MVPS-XL 71714 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 41 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax® 41 71719 30199 30255 30192 29676 96721 96715 29672 23672 29622 23674 29624 23671 29621 97782 23673 29623 GE332MAX-N/ULTRA GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-MVPS-H GE332-MVPS-L GE332-MVPS-N GE-332-MVPS-XL GE-232-277-N GE-232-277-PS-N GE-332-277-N GE-332-277-PS-N GE-232-120-N GE-232-120-PS-N GE232-120-RES GE-332-120-N GE-332-120-PS-N 72258 GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax® 38 72259 72269 GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax® GE-132-MV-N 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 38 46 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 72262 GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax® 39 72266 30198 30198 72273 72275 72275 29675 96720 GE232MAX-N/ULTRA GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N GE-232-MV-N GE-232-MVPS-H GE232-MVPS-L 96714 29671 23681 23672 29622 23680 23671 29621 97782 24109 24107 24109 97498 80644 24107 72110 72110 89709 80644 24109 24107 24109 24107 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax® 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF Residential ProLine® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 42 48 48 49 64 65 64 65 54 60 55 63 54 60 58 55 63 40 46 46 47 47 47 62 61 GE232-MVPS-N GE-232-MVPS-XL GE-132-277-N GE-232-277-N GE-232-277-PS-N GE-132-120-N GE-232-120-N GE-232-120-PS-N GE232-120-RES GE-340-RS-MV-N GE-240-RS-MV-N GE-340-RS-MV-N GE240RS120 GEM230RS120DIY GE-240-RS-MV-N GE140RS120-DIY GE140RS120-DIY GEM140RS120DIY GEM230RS120DIY GE-340-RS-MV-N GE-240-RS-MV-N GE-340-RS-MV-N GE-240-RS-MV-N 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 1 - F32T8 277V “N”.87 BF ProLine® 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 1 - F32T8 120V “N”.87 BF ProLine® 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF Residential ProLine® 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 F40 or F34T12 Rapid Start Electronic 120V “N” BF 2 - F30T12 120V Magnetic Ballast (573LTCP) 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack 1 F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack 1 - F40T12 F30T12 F48/25W 120V Magnetic Ballast (413CTCP) 2 - F30T12 120V Magnetic Ballast (573LTCP) 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 71423 71832 GE432MAX-N+ GE432-MVPS-L 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 44 67 71422 GE332MAX-N+ 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 42 61 62 53 54 60 53 54 60 58 86 85 86 85 94 85 86 86 93 94 86 85 86 85 23 HID Electromagnetic Ballasts 3 44 67 HID Electronic Ballasts 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 120 120 120 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® Compact Fluorescent Ballasts 4 4 4 4 4 4 4 4 4 4 4 4 GE432MAX-N+ GE432-MVPS-L Prod Code Page No Sign Ballasts 120-277 71423 71832 Fluorescent Ballast Long Description T12 Fluorescent Ballasts 4 Linear Fluorescent Lamps ® Ballast Product Code Ballast Description T5 Fluorescent Ballasts F28T8 4 4 Electronic - High Efficiency Multivolt Instant Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start # of Lamp Type Lamps Voltage Fluorescent Ballast Type T8 Fluorescent Ballasts # of Lamp Type Lamps Voltage Fluorescent Ballast Type Quick Reference Guides gelighting.com Quick reference lamp to ballast selection guide (cont.) Ballast Product Code Ballast Description Prod Code Page No Fluorescent Ballast Long Description Linear Fluorescent Lamps 120-277 120-277 2 120-277 120-277 1 120-277 4 120-277 4 120-277 4 4 4 4 4 4 4 4 4 4 4 4 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 120 120 120 3 120-277 3 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 3 120-277 3 2 120-277 2 120-277 71421 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 71422 GE332MAX-N+ ® 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 42 71421 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 43 71725 GE432MAX-L/ULTRA 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax® 43 71727 30219 30262 30193 30193 29678 96716 23676 29627 23675 29625 97783 GE432MAX-N/ULTRA GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-MVPS-H GE432-MVPS-N GE-432-277-N GE-432-277-PS-N GE-432-120-N GE-432-120-PS-N GE432-120-RES 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax® 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B 44 49 50 50 50 68 67 56 66 56 66 58 71714 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 41 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax® 41 ® 71719 30199 30255 30192 29676 96721 96715 29672 GE332MAX-N/ULTRA GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-MVPS-H GE332-MVPS-L GE332-MVPS-N GE-332-MVPS-XL 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 71725 GE432MAX-L/ULTRA 71727 30219 30262 30193 30193 29678 96716 80358 80358 23674 29624 23676 29627 80357 80357 23673 29623 23675 29625 97783 GE432MAX-N/ULTRA GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-MVPS-H GE432-MVPS-N B332SR277V5 B332SR277V5 GE-332-277-N GE-332-277-PS-N GE-432-277-N GE-432-277-PS-N B332SR120V5 B332SR120V5 GE-332-120-N GE-332-120-PS-N GE-432-120-N GE-432-120-PS-N GE432-120-RES 49775 72262 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD ® 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax ® 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 DIM 100 to 5% RS 277 3 - F32T8 DIM 100 to 5% RS 277 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 - F32T8 DIM 100 to 5% RS 120 3 - F32T8 DIM 100 to 5% RS 120 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B 42 48 48 49 64 65 64 65 F32T8 (cont) 120-277 120-277 120-277 120-277 2 120-277 2 120-277 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 277 277 277 277 277 277 277 120 120 120 120 120 120 120 120 1 120-277 1 1 120-277 120-277 43 1 120-277 43 1 120-277 44 49 50 50 50 68 67 71 71 55 63 56 66 71 71 55 63 56 66 58 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 120 120 120 120 120 120 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 4 4 120-277 120-277 GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax® 39 3 120-277 3 3 120-277 120-277 2 120-277 F32T8/WM 72266 30198 30198 72273 72275 72275 2 2 2 2 GE232MAX-N/ULTRA GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N GE-232-MV-N 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 40 46 46 47 47 47 See page 195 for warranty information. Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Dimming Electronic - Dimming Electronic - Dimming Electronic - Dimming Electronic - Dimming Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Dimming Electronic - Dimming Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Dimming Electronic - Dimming Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start See page 195 for warranty information. 2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 62 61 61 62 29675 96720 96714 29671 GE-232-MVPS-H GE232-MVPS-L GE232-MVPS-N GE-232-MVPS-XL 71714 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 41 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax® 41 71719 30199 30255 30192 29676 96721 96715 29672 80362 80362 80362 80356 80356 23672 29622 23674 29624 87130 80355 80355 23671 29621 97782 23673 29623 87125 GE332MAX-N/ULTRA GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-MVPS-H GE332-MVPS-L GE332-MVPS-N GE-332-MVPS-XL B232SR277S50 B232SR277S50 B232SR277S50 B232SR277V5 B232SR277V5 GE-232-277-N GE-232-277-PS-N GE-332-277-N GE-332-277-PS-N GEM232T8RS277 B232SR120V5 B232SR120V5 GE-232-120-N GE-232-120-PS-N GE232-120-RES GE-332-120-N GE-332-120-PS-N GEM232T8RS120 72258 GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax® 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax® 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 2 - F32T8 Switch 100/50% RS 277 2 - F32T8 Switch 100/50% RS 277 2 - F32T8 Switch 100/50% RS 277 2 - F32T8 DIM 100 to 5% RS 277 2 - F32T8 DIM 100 to 5% RS 277 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 2 - F32T8 RS 277V Magnetic Ballast (M232SR277C) 2 - F32T8 DIM 100 to 5% RS 120 2 - F32T8 DIM 100 to 5% RS 120 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF Residential ProLine® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 - F32T8 RS 120V Magnetic Ballast (M232SR120C) 42 48 48 49 64 65 64 65 70 70 70 70 70 54 60 55 63 59 69 69 54 60 58 55 63 59 38 ® 72259 72269 GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax GE-132-MV-N 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 38 46 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 72262 GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax® 39 ® 72266 30198 30198 72273 72275 72275 29675 96720 96714 29671 23681 23672 29622 80353 80353 23680 23671 29621 97782 GE232MAX-N/ULTRA GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N GE-232-MV-N GE-232-MVPS-H GE232-MVPS-L GE232-MVPS-N GE-232-MVPS-XL GE-132-277-N GE-232-277-N GE-232-277-PS-N B132R120V5 B132R120V5 GE-132-120-N GE-232-120-N GE-232-120-PS-N GE232-120-RES 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 1 - F32T8 277V “N”.87 BF ProLine® 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 1 - F32T8 DIM 100 to 5% RS 120 1 - F32T8 DIM 100 to 5% RS 120 1 - F32T8 120V “N”.87 BF ProLine® 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF Residential ProLine® 40 46 46 47 47 47 62 61 61 62 53 54 60 69 69 53 54 60 58 71423 71832 GE432MAX-N+ GE432-MVPS-L 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 44 67 71422 GE332MAX-N+ 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 42 71423 71832 GE432MAX-N+ GE432-MVPS-L 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 44 67 71421 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 25 HID Electromagnetic Ballasts 120-277 120-277 120-277 120-277 120-277 120-277 44 67 HID Electronic Ballasts 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 277 277 277 120 120 120 120 120 120 120 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® Compact Fluorescent Ballasts 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 24 120-277 GE432MAX-N+ GE432-MVPS-L Sign Ballasts 3 3 3 3 3 3 3 3 71423 71832 Prod Code Page No Fluorescent Ballast Long Description T12 Fluorescent Ballasts 2 Linear Fluorescent Lamps ® Ballast Product Code Ballast Description T5 Fluorescent Ballasts F32T8 (cont) 3 3 Electronic - High Efficiency Multivolt Instant Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Dimming Electronic - Dimming Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Dimming Electronic - Dimming Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start # of Lamp Type Lamps Voltage Fluorescent Ballast Type T8 Fluorescent Ballasts # of Lamp Type Lamps Voltage Fluorescent Ballast Type Quick Reference Guides gelighting.com Quick reference lamp to ballast selection guide (cont.) Ballast Product Code Ballast Description Prod Code Page No Fluorescent Ballast Long Description Linear Fluorescent Lamps 2 120-277 1 120-277 4 120-277 4 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 120 120 120 3 120-277 3 120-277 3 3 3 3 3 3 3 3 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 3 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 277 120 120 120 120 120 2 120-277 2 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 2 120-277 2 120-277 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax 42 71421 GE232MAX-N+ 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 40 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 43 71725 GE432MAX-L/ULTRA ® 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax ® 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B 43 71727 30219 30262 30193 30193 29678 96716 23676 29627 23675 29625 97783 GE432MAX-N/ULTRA GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-MVPS-H GE432-MVPS-N GE-432-277-N GE-432-277-PS-N GE-432-120-N GE-432-120-PS-N GE432-120-RES 71714 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 41 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax® 71719 30199 30255 30192 29676 96721 96715 29672 GE332MAX-N/ULTRA GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-MVPS-H GE332-MVPS-L GE332-MVPS-N GE-332-MVPS-XL 71723 GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax® 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD ® 44 49 50 50 50 68 67 56 66 56 66 58 72266 30198 30198 72273 72275 72275 29675 96720 96714 29671 23681 23672 29622 23680 23671 29621 97782 24109 24107 24109 97498 97498 24107 72110 72110 89714 89709 47536 GE232MAX-N/ULTRA GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N GE-232-MV-N GE-232-MVPS-H GE232-MVPS-L GE232-MVPS-N GE-232-MVPS-XL GE-132-277-N GE-232-277-N GE-232-277-PS-N GE-132-120-N GE-232-120-N GE-232-120-PS-N GE232-120-RES GE-340-RS-MV-N GE-240-RS-MV-N GE-340-RS-MV-N GE240RS120 GE240RS120 GE-240-RS-MV-N GE140RS120-DIY GE140RS120-DIY GEM140HRS120DIY GEM140RS120DIY B228PUNV-C0G1C 2 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 2 1 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start 99653 47536 GE228MVPSH-A B228PUNV-C0G1C 1 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 1 120-277 Electronic - Program / Rapid Start 99653 GE228MVPSH-A 2 120-277 Electronic - Program / Rapid Start 99655 GE228MVPS-A 1 2 1 1 120-277 120-277 120-277 120-277 99655 47540 47534 47540 GE228MVPS-A B239PUNV-DOG1C B224PUNV-COG1C B239PUNV-DOG1C 1 120-277 120-277 120-277 41 1 120-277 42 48 48 49 64 65 64 65 1 120-277 F32T8/WM (cont) 43 GE432MAX-L/ULTRA 4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax 43 71727 30219 30262 30193 30193 29678 96716 23674 29624 23676 29627 23673 29623 23675 29625 97783 GE432MAX-N/ULTRA GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-MVPS-H GE432-MVPS-N GE-332-277-N GE-332-277-PS-N GE-432-277-N GE-432-277-PS-N GE-332-120-N GE-332-120-PS-N GE-432-120-N GE-432-120-PS-N GE432-120-RES 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax® 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B 44 49 50 50 50 68 67 55 63 56 66 55 63 56 66 58 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 72262 GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax® 39 F34T12 F35T5/HE 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 120 120 120 120 120-277 120-277 120-277 120 120 120-277 120 120 120 120 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 277 277 277 120 120 120 120 120 1 1 71725 ® 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 2 2 2 2 1 1 1 1 1 2 Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 72266 30198 30198 72273 72275 72275 29675 96720 96714 29671 GE232MAX-N/ULTRA GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N GE-232-MV-N GE-232-MVPS-H GE232-MVPS-L GE232-MVPS-N GE-232-MVPS-XL 71714 GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 41 71717 GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax® 41 40 46 46 47 47 47 62 61 61 62 See page 195 for warranty information. F35T5/WM F39T5/HO Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start See page 195 for warranty information. 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax® 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF Residential ProLine® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 71719 30199 30255 30192 29676 96721 96715 29672 23672 29622 23674 29624 23671 29621 97782 23673 29623 GE332MAX-N/ULTRA GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-MVPS-H GE332-MVPS-L GE332-MVPS-N GE-332-MVPS-XL GE-232-277-N GE-232-277-PS-N GE-332-277-N GE-332-277-PS-N GE-232-120-N GE-232-120-PS-N GE232-120-RES GE-332-120-N GE-332-120-PS-N 72258 GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax® 42 48 48 49 64 65 64 65 54 60 55 63 54 60 58 55 63 38 ® 72259 72269 GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax GE-132-MV-N 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 38 46 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 72262 GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax® 39 ® 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® 2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® 2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® 2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD 1 - F32T8 277V “N”.87 BF ProLine® 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart® 1 - F32T8 120V “N”.87 BF ProLine® 2 or 1 - F32T8 120V “N”.87 BF ProLine® 2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart® 2 or 1 - F32T8 120V “N”.87 BF Residential ProLine® 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 F40 or F34T12 Rapid Start Electronic 120V “N” BF 2 F40 or F34T12 Rapid Start Electronic 120V “N” BF 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack 1 F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack 1 - F40T12 F40T12 120V Magnetic Ballast (412LSLHTCP) 1 - F40T12 F30T12 F48/25W 120V Magnetic Ballast (413CTCP) 2 - F28T5 PRS UNV 50/60 Hz 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 12 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 - F28T5 PRS UNV 50/60 Hz 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 11 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95 BF A Can 2 - F39T5HO PRS UNV 50/60 Hz 2 - F24T5HO PRS UNV 50/60 Hz 2 - F39T5HO PRS UNV 50/60 Hz 40 46 46 47 47 47 62 61 61 62 53 54 60 53 54 60 58 86 85 86 85 85 85 86 86 93 93 78 77 77 78 77 77 77 77 79 79 79 27 HID Electromagnetic Ballasts 2 2 2 2 2 2 2 2 2 2 GE332MAX-N+ HID Electronic Ballasts 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 71422 Compact Fluorescent Ballasts 120-277 Linear Fluorescent Lamps ® Sign Ballasts 3 Prod Code Page No Fluorescent Ballast Long Description T12 Fluorescent Ballasts 26 4 4 4 4 4 4 4 4 4 4 4 4 Ballast Product Code Ballast Description T5 Fluorescent Ballasts F32T8/WM (cont) 120-277 Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start # of Lamp Type Lamps Voltage Fluorescent Ballast Type T8 Fluorescent Ballasts # of Lamp Type Lamps Voltage Fluorescent Ballast Type Quick Reference Guides gelighting.com Quick reference lamp to ballast selection guide (cont.) Linear Fluorescent Lamps F40T10 F40T12/ WMP F48T8/HO 28 1 120-277 1 120-277 1 1 120-277 120 3 3 3 3 3 3 3 120-277 120-277 120-277 120-277 120-277 277 120 2 2 120-277 120-277 2 2 2 2 2 2 1 1 1 1 1 120-277 120-277 120-277 120-277 277 120 120-277 120-277 120-277 120-277 120-277 1 1 1 2 2 2 1 1 1 2 2 2 1 120-277 120-277 277 120-277 277 120 120-277 120 120 120-277 120-277 120-277 120-277 86 85 86 95 94 95 85 93 96 86 86 85 86 95 85 85 94 95 85 86 93 93 86 95 95 86 86 94 93 71423 GE432MAX-N+ 4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 44 71422 GE332MAX-N+ 3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 42 49766 GE159MAX-N/ULTRA 1 - F96T8 120 to 277 “N” .87 BF UltraMax® 45 49775 GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 39 71421 23671 GE232MAX-N+ GE-232-120-N 2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax® 2 or 1 - F32T8 120V “N”.87 BF ProLine® 40 54 71723 30219 30262 30193 30193 23676 23675 GE432MAX-H/ULTRA GE-432-MV-H GE-432-MV-L GE-432-MV-N GE-432-MV-N GE-432-277-N GE-432-120-N 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 4 or 3 - F32T8 277V “N”.87 BF ProLine® 4 or 3 - F32T8 120V “N”.87 BF ProLine® 43 49 50 50 50 56 56 F72T12/HO 49767 30176 GE259MAX-N/ULTRA 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax® GE-286-HO-MV-N 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 45 52 F72T8 71714 30199 30255 30192 23674 23673 30198 30198 72273 72275 72275 GE332MAX-H/ULTRA GE-332-MV-H GE-332-MV-L GE-332-MV-N GE-332-277-N GE-332-120-N GE-232-MV-H GE-232-MV-H GE-232-MV-L GE-232-MV-N GE-232-MV-N 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax® 3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine® 3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 3 or 2 - F32T8 277V “N”.87 BF ProLine® 3 or 2 - F32T8 120V “N”.87 BF ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine® 41 48 48 49 55 55 46 46 47 47 47 49767 30176 23672 24108 86379 86360 24108 72110 89709 72109 72109 30176 30176 GE259MAX-N/ULTRA GE-286-HO-MV-N GE-232-277-N GE-260-IS-MV-N GEM296IS277IP GEM296IS120IP GE-260-IS-MV-N GE140RS120-DIY GEM140RS120DIY GE296HO-MV-N GE296HO-MV-N GE-286-HO-MV-N GE-286-HO-MV-N 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F32T8 277V “N”.87 BF ProLine® 2 or 1 - F96T12 Instant Start 120 to 277 2 - F96T12 IS 277V Magnetic Ballast (827SLHTCP) 2 - F96T12 IS 120V Magnetic Ballast (806SLHTCP) 2 or 1 - F96T12 Instant Start 120 to 277 1 F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack 1 - F40T12 F30T12 F48/25W 120V Magnetic Ballast (413CTCP) 2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine® 2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine® 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 45 52 54 87 98 98 87 86 93 89 89 52 52 See page 195 for warranty information. F4T5 F54T5/HO F54T5/WM F58T8 F58T8 (cont) F60T12 F60T12/HO F60T8/HO F64T12 F6T5 F72T12 F72T8/HO F73T12/HO F84T12 F84T12/HO F8T5 F8T9 F96T12 F96T12/HO 1 4 4 3 3 2 2 2 2 1 1 1 1 4 3 2 2 1 1 4 3 2 2 2 1 1 1 2 1 2 2 2 1 2 1 1 2 2 2 1 1 1 2 2 2 2 2 2 2 277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 120-277 277 120 120-277 277 120 120-277 277 277 120 120 120 120-277 2 120-277 1 2 1 2 2 1 2 2 1 1 2 2 2 1 1 1 1 2 2 2 2 2 2 1 120-277 120-277 120-277 120 120-277 120-277 277 120 277 120 120-277 277 120 120-277 277 120 120-277 120-277 120-277 277 277 120 120 120-277 Magnetic - Preheat Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Magnetic - Preheat Electronic - Multivolt Instant Start Magnetic - Standard Instant Start Magnetic - Standard Instant Start Electronic - Multivolt Instant Start Magnetic - Standard Instant Start Magnetic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Preheat Electronic - Program / Rapid Start Electronic - Multivolt Instant Start Magnetic - Standard Instant Start Magnetic - Standard Instant Start Electronic - Multivolt Instant Start Magnetic - Standard Instant Start Magnetic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start See page 195 for warranty information. 87634 99649 29726 99649 29726 47542 99651 99649 29726 47542 99651 99649 29726 99649 99649 99651 99649 99651 99649 99649 99649 99651 30176 99649 99651 30176 99649 24108 24108 72109 72109 30176 30176 24108 24108 87634 24108 86379 86360 24108 86381 86372 72109 80163 86171 80664 80162 86164 72109 GEM1CF579PH277 GE454MVPS90-E GE454MVPSN1 GE454MVPS90-E GE454MVPSN1 B254PUNV-DGE1C GE254MVPS90-F GE454MVPS90-E GE454MVPSN1 B254PUNV-DGE1C GE254MVPS90-F GE454MVPS90-E GE454MVPSN1 GE454MVPS90-E GE454MVPS90-E GE254MVPS90-F GE454MVPS90-E GE254MVPS90-F GE454MVPS90-E GE454MVPS90-E GE454MVPS90-E GE254MVPS90-F GE-286-HO-MV-N GE454MVPS90-E GE254MVPS90-F GE-286-HO-MV-N GE454MVPS90-E GE-260-IS-MV-N GE-260-IS-MV-N GE296HO-MV-N GE296HO-MV-N GE-286-HO-MV-N GE-286-HO-MV-N GE-260-IS-MV-N GE-260-IS-MV-N GEM1CF579PH277 GE-260-IS-MV-N GEM296IS277IP GEM296IS120IP GE-260-IS-MV-N GEM196IS277IP GEM196IS120IP GE296HO-MV-N B295SR277HP GEM296HORS277IP 493B2 B295SR120HP GEM296HORS120IP GE296HO-MV-N 49767 GE259MAX-N/ULTRA 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax® 49767 30176 30176 80664 24108 24108 80163 80162 87634 97498 24108 86379 86360 24108 86381 86372 72109 72109 72109 80163 86171 80162 86164 72109 ® GE259MAX-N/ULTRA GE-286-HO-MV-N GE-286-HO-MV-N 493B2 GE-260-IS-MV-N GE-260-IS-MV-N B295SR277HP B295SR120HP GEM1CF579PH277 GE240RS120 GE-260-IS-MV-N GEM296IS277IP GEM296IS120IP GE-260-IS-MV-N GEM196IS277IP GEM196IS120IP GE296HO-MV-N GE296HO-MV-N GE296HO-MV-N B295SR277HP GEM296HORS277IP B295SR120HP GEM296HORS120IP GE296HO-MV-N 1 - CFT579Q9W/G23 Preheat 277 (4205F2P) 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4,3,2 or 1 - F54T5HO 120-277V UltraStart® PRS Stick Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4,3,2 or 1 - F54T5HO 120-277V UltraStart® PRS Stick Can 2 - F54T5HO PRS UNV 50/60 Hz 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4,3,2 or 1 - F54T5HO 120-277V UltraStart® PRS Stick Can 2 - F54T5HO PRS UNV 50/60 Hz 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4,3,2 or 1 - F54T5HO 120-277V UltraStart® PRS Stick Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 or 1 - F96T12 Instant Start 120 to 277 2 or 1 - F96T12 Instant Start 120 to 277 2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine® 2 or 1- F96T12 HO RS 120 to 277 Multivolt ProLine® 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T12 Instant Start 120 to 277 2 or 1 - F96T12 Instant Start 120 to 277 1 - CFT579Q9W/G23 Preheat 277 (4205F2P) 2 or 1 - F96T12 Instant Start 120 to 277 2 - F96T12 IS 277V Magnetic Ballast (827SLHTCP) 2 - F96T12 IS 120V Magnetic Ballast (806SLHTCP) 2 or 1 - F96T12 Instant Start 120 to 277 1 - F96T12 IS 277 Magnetic Ballast (828BRTCP) 1 - F96T12 IS 120 Magnetic Ballast (822BRTCP) 2 or 1- F96T12 HO RS 120 to 277 Multivolt ProLine® 2 - F96T12HOES RS 277 2 - F96T12HO RS 277V Magnetic Ballast (487SLHTCP) 2 - F73T12/BL/HO Suntan 120 Magnetic Ballast 2 - F96T12HOES RS 120 2 - F96T12HO F72T12HO RS 120V Magnetic Ballast (480SLHTCP) 2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine® 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 - F73T12/BL/HO Suntan 120 Magnetic Ballast 2 or 1 - F96T12 Instant Start 120 to 277 2 or 1 - F96T12 Instant Start 120 to 277 2 - F96T12HOES RS 277 2 - F96T12HOES RS 120 1 - CFT579Q9W/G23 Preheat 277 (4205F2P) 2 F40 or F34T12 Rapid Start Electronic 120V “N” BF 2 or 1 - F96T12 Instant Start 120 to 277 2 - F96T12 IS 277V Magnetic Ballast (827SLHTCP) 2 - F96T12 IS 120V Magnetic Ballast (806SLHTCP) 2 or 1 - F96T12 Instant Start 120 to 277 1 - F96T12 IS 277 Magnetic Ballast (828BRTCP) 1 - F96T12 IS 120 Magnetic Ballast (822BRTCP) 2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine® 2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine® 2 or 1- F96T12 HO RS 120 to 277 Multivolt ProLine® 2 - F96T12HOES RS 277 2 - F96T12HO RS 277V Magnetic Ballast (487SLHTCP) 2 - F96T12HOES RS 120 2 - F96T12HO F72T12HO RS 120V Magnetic Ballast (480SLHTCP) 2 or 1- F96T12 HO RS 120 to 277 Multivolt ProLine® 128 81 81 81 81 80 80 81 81 80 80 81 81 81 81 80 81 80 81 81 81 80 52 81 80 52 81 87 87 89 89 52 52 87 87 128 87 98 98 87 97 97 89 88 99 100 88 99 89 45 45 52 52 100 87 87 88 88 128 85 87 98 98 87 97 97 89 89 89 88 99 88 99 89 29 HID Electromagnetic Ballasts F48T12/HO 120-277 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 - F40T12 RS 277V Magnetic Ballast (443LSLHTCP) 2 - F40T12 F40T12 120V Magnetic Ballast (420LTCP) 2 - F40T12 RS 120V Magnetic Ballast (446LSLHTCP) 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 1 - F40T12 F40T12 120V Magnetic Ballast (412LSLHTCP) 2 - F40T12 F40T10 220V Magnetic Ballast (754LTCP) 1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 - F40T12 RS 277V Magnetic Ballast (443LSLHTCP) 2 F40 or F34T12 Rapid Start Electronic 120V “N” BF 2 F40 or F34T12 Rapid Start Electronic 120V “N” BF 2 - F40T12 F40T12 120V Magnetic Ballast (420LTCP) 2 - F40T12 RS 120V Magnetic Ballast (446LSLHTCP) 2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 1 F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack 1 - F40T12 F40T12 120V Magnetic Ballast (412LSLHTCP) 1 - F40T12 F30T12 F48/25W 120V Magnetic Ballast (413CTCP) 1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack 2 - F40T12 RS 277V Magnetic Ballast (443LSLHTCP) 2 - F40T12 RS 120V Magnetic Ballast (446LSLHTCP) 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 2 - F40T12 F40T12 120V Magnetic Ballast (420LTCP) 1 - F40T12 F40T12 120V Magnetic Ballast (412LSLHTCP) HID Electronic Ballasts F48T12/ 25W 2 GE-340-RS-MV-N GE-240-RS-MV-N GE-340-RS-MV-N GEM240RS277IP GEM240HRS120DIY GEM240RS120IP GE-240-RS-MV-N GEM140HRS120DIY GEM240RS220IP GE140RS120-DIY GE-340-RS-MV-N GE-240-RS-MV-N GE-340-RS-MV-N GEM240RS277IP GE240RS120 GE240RS120 GEM240HRS120DIY GEM240RS120IP GE-240-RS-MV-N GE140RS120-DIY GEM140HRS120DIY GEM140RS120DIY GE140RS120-DIY GEM240RS277IP GEM240RS120IP GE-340-RS-MV-N GE-340-RS-MV-N GEM240HRS120DIY GEM140HRS120DIY Prod Code Page No Fluorescent Ballast Long Description Compact Fluorescent Ballasts F48T12 120-277 Linear Fluorescent Lamps 24109 24107 24109 86124 89710 86139 24107 89714 86341 72110 24109 24107 24109 86124 97498 97498 89710 86139 24107 72110 89714 89709 72110 86124 86139 24109 24109 89710 89714 Ballast Product Code Ballast Description Sign Ballasts F40T8 3 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Magnetic - Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Program / Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Multivolt Instant Start Magnetic - Standard Instant Start Magnetic - Standard Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Fluorescent Ballast Long Description # of Lamp Type Lamps Voltage Fluorescent Ballast Type T12 Fluorescent Ballasts F40T12/ WM 120-277 120-277 120-277 277 120 120 120-277 120 220 120 120-277 120-277 120-277 277 120 120 120 120 120-277 120 120 120 120 277 120 120-277 120-277 120 120 Prod Code Page No T5 Fluorescent Ballasts F40T12 3 2 2 2 2 2 1 1 2 1 3 2 2 2 2 2 2 2 1 1 1 1 1 2 2 3 2 2 1 Ballast Product Code Ballast Description T8 Fluorescent Ballasts # of Lamp Type Lamps Voltage Fluorescent Ballast Type Quick Reference Guides gelighting.com Quick reference lamp to ballast selection guide (cont.) Linear Fluorescent Lamps F96T12/ HO/WM F96T12/ WM F96T12/ WMP F96T8/HO/ WM 1 1 120-277 120-277 1 1 1 1 1 2 1 2 2 2 2 120-277 120-277 120-277 277 120 120-277 120-277 277 277 120 120 2 2 2 2 2 120-277 120-277 120-277 277 120 1 1 120-277 120-277 1 1 1 1 1 120-277 120-277 120-277 277 120 2 2 2 2 2 F96T8/ WMP 120-277 120-277 120-277 277 120 120-277 120-277 1 1 1 1 1 120-277 120-277 120-277 277 120 2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine® 2 or 1- F96T12 HO RS 120 to 277 Multivolt ProLine® 2 or 1 - F96T12 Instant Start 120 to 277 2 - F96T12 IS 277V Magnetic Ballast (827SLHTCP) 2 - F96T12 IS 120V Magnetic Ballast (806SLHTCP) 2 or 1 - F96T12 Instant Start 120 to 277 1 - F96T12 IS 277 Magnetic Ballast (828BRTCP) 1 - F96T12 IS 120 Magnetic Ballast (822BRTCP) 2 or 1 - F96T12 Instant Start 120 to 277 2 or 1 - F96T12 Instant Start 120 to 277 ® 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax 2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T8 277v “N”.87 BF ProLine® 2 or 1 - F96T8 120v Normal Light .87 BF ProLine® 89 89 87 98 98 87 97 97 87 87 49767 30194 30176 23678 23677 GE259MAX-N/ULTRA GE-259-MV-N GE-286-HO-MV-N GE-259-277-N GE-259-120-N 49766 30195 GE159MAX-N/ULTRA 1 - F96T8 120 to 277 “N” .87 BF UltraMax® GE-159-MV-N 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine® 49767 30194 30176 23678 23677 30176 30176 80163 86171 80162 86164 GE259MAX-N/ULTRA GE-259-MV-N GE-286-HO-MV-N GE-259-277-N GE-259-120-N GE-286-HO-MV-N GE-286-HO-MV-N B295SR277HP GEM296HORS277IP B295SR120HP GEM296HORS120IP 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T8 277v “N”.87 BF ProLine® 2 or 1 - F96T8 120v Normal Light .87 BF ProLine® 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 - F96T12HOES RS 277 2 - F96T12HO RS 277V Magnetic Ballast (487SLHTCP) 2 - F96T12HOES RS 120 2 - F96T12HO F72T12HO RS 120V Magnetic Ballast (480SLHTCP) 45 51 52 57 57 52 52 88 99 88 99 49767 30194 30176 23678 23677 GE259MAX-N/ULTRA GE-259-MV-N GE-286-HO-MV-N GE-259-277-N GE-259-120-N 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T8 277v “N”.87 BF ProLine® 2 or 1 - F96T8 120v Normal Light .87 BF ProLine® 45 51 52 57 57 49766 30195 GE159MAX-N/ULTRA 1 - F96T8 120 to 277 “N” .87 BF UltraMax® GE-159-MV-N 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine® 49767 30194 30176 23678 23677 GE259MAX-N/ULTRA GE-259-MV-N GE-286-HO-MV-N GE-259-277-N GE-259-120-N 45 51 52 57 57 45 51 Circleline Fluorescent Lamps FC12T5HO FC12T9 FC16T9 FC6T9 FC8T9 49767 30194 30176 23678 23677 GE259MAX-N/ULTRA GE-259-MV-N GE-286-HO-MV-N GE-259-277-N GE-259-120-N 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T8 277v “N”.87 BF ProLine® 2 or 1 - F96T8 120v Normal Light .87 BF ProLine® CFM36W/ 2G10 CFM42W CFM57W CFM70W CFQ13W/ 2P CFQ13W/ G24q CFQ18W/ G24q 45 51 ® 49766 30195 GE159MAX-N/ULTRA 1 - F96T8 120 to 277 “N” .87 BF UltraMax GE-159-MV-N 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine® 49767 30194 30176 23678 23677 GE259MAX-N/ULTRA GE-259-MV-N GE-286-HO-MV-N GE-259-277-N GE-259-120-N 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T8 277v “N”.87 BF ProLine® 2 or 1 - F96T8 120v Normal Light .87 BF ProLine® 45 51 52 57 57 45 51 52 57 57 CFQ26W/ G24q 45 51 45 51 52 57 57 CFS16W/ GR10q CFS21W/ GR10q CFT13W/2P See page 195 for warranty information. Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start 99649 99649 47542 99649 99651 47542 99649 99651 89717 97498 97498 89720 97499 89720 GE454MVPS90-E GE454MVPS90-E B254PUNV-DGE1C GE454MVPS90-E GE254MVPS90-F B254PUNV-DGE1C GE454MVPS90-E GE254MVPS90-F GEM1FC12T9RS120 GE240RS120 GE240RS120 GEM1FC16T9RS120 GE240RS120 GEM1FC16T9RS120 1 120-277 Electronic - Program / Rapid Start 71444 GEC226-MVPS-XX 1 1 2 1 120-277 120 120 120 71445 86227 89717 86227 GEC226-MVPS-3W GEM1FC8T9RS120IP GEM1FC12T9RS120 GEM1FC8T9RS120IP Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Rapid Start Magnetic - Rapid Start 2 1 2 1 1 1 2 1 2 2 1 1 1 1 2 2 1 1 2 2 120-277 120-277 120-277 120-277 120-277 120-277 277 120 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 277 120-277 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Preheat Magnetic - Preheat Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Preheat Electronic - Program / Rapid Start 47506 47506 47506 47506 47506 47506 87655 87533 71430 71429 71430 71429 71430 71429 71434 71433 71434 71433 87700 47506 C242UNVBES-IP C242UNVBES-IP C242UNVBES-IP C242UNVBES-IP C242UNVBES-IP C242UNVBES-IP GEM2CF13PH277 GEM1CF13PH120 GEC213-MVPS-3W GEC213-MVPS-XX GEC213-MVPS-3W GEC213-MVPS-XX GEC213-MVPS-3W GEC213-MVPS-XX GEC218-MVPS-3W GEC218-MVPS-XX GEC218-MVPS-3W GEC218-MVPS-XX GEM2CF24PH277 C242UNVBES-IP 2 120-277 Electronic - Program / Rapid Start 71445 GEC226-MVPS-3W 2 1 1 1 1 120-277 120-277 120-277 120-277 120-277 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start 71444 71434 71434 71433 71433 GEC226-MVPS-XX GEC218-MVPS-3W GEC218-MVPS-3W GEC218-MVPS-XX GEC218-MVPS-XX 1 120-277 Electronic - Program / Rapid Start 71445 GEC226-MVPS-3W 1 2 2 2 2 1 1 1 1 2 2 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start 71444 71430 71429 71434 71433 71430 71430 71429 71429 71434 71433 GEC226-MVPS-XX GEC213-MVPS-3W GEC213-MVPS-XX GEC218-MVPS-3W GEC218-MVPS-XX GEC213-MVPS-3W GEC213-MVPS-3W GEC213-MVPS-XX GEC213-MVPS-XX GEC218-MVPS-3W GEC218-MVPS-XX 2 120-277 Electronic - Program / Rapid Start 71445 GEC226-MVPS-3W 2 1 1 2 1 1 2 1 120-277 120-277 120-277 120-277 120-277 120-277 277 120 71444 71434 71433 47506 71434 71433 87655 87533 GEC226-MVPS-XX GEC218-MVPS-3W GEC218-MVPS-XX C242UNVBES-IP GEC218-MVPS-3W GEC218-MVPS-XX GEM2CF13PH277 GEM1CF13PH120 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Preheat Magnetic - Preheat See page 195 for warranty information. 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 - F54T5HO PRS UNV 50/60 Hz 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 2 - F54T5HO PRS UNV 50/60 Hz 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 2 FC12T9 RS 120V Magnetic Ballast (449LRWSTCP) 5 - F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12 4 - F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12 2 - FC12T9 FC16T9 FC8T9 FC12T9 120V Magnetic (726VLHWSTCP) 3 - F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12 2 - FC12T9 FC16T9 FC8T9 FC12T9 120V Magnetic (726VLHWSTCP) 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V ProLine® PS 1 - FC8T9 RS 120V Magnetic Ballast (547RSWSTCP) 2 FC12T9 RS 120V Magnetic Ballast (449LRWSTCP) 1 - FC8T9 RS 120V Magnetic Ballast (547RSWSTCP) 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2 - CFT/Q13W/GX23 Preheat 277 (4214PBES) 1 - CFT/Q13W/GX23 Preheat 120 (4111H2P) 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 2 - CFQ26W/G24d Preheat 277 (4226PBES) 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit 2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 2 - CFT/Q13W/GX23 Preheat 277 (4214PBES) 1 - CFT/Q13W/GX23 Preheat 120 (4111H2P) 81 81 80 81 80 80 81 80 92 85 85 91 91 124 124 91 92 91 124 124 124 124 124 124 129 128 123 123 123 123 123 123 123 123 123 123 129 124 124 124 123 123 123 123 124 124 123 123 123 123 123 123 123 123 123 123 124 123 123 123 123 123 129 128 31 HID Electromagnetic Ballasts CFS28W/ GR10q 30 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120 120 120 120 120 120 Compact Fluorescent Lamps CFQ26W/2P 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax® 2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine® 2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF 2 or 1 - F96T8 277v “N”.87 BF ProLine® 2 or 1 - F96T8 120v Normal Light .87 BF ProLine® 4 3 2 2 2 1 1 1 2 2 1 1 1 1 Prod Code Page No HID Electronic Ballasts 1 1 GE296HO-MV-N GE296HO-MV-N GE-260-IS-MV-N GEM296IS277IP GEM296IS120IP GE-260-IS-MV-N GEM196IS277IP GEM196IS120IP GE-260-IS-MV-N GE-260-IS-MV-N Fluorescent Ballast Long Description Compact Fluorescent Ballasts 120-277 120-277 120-277 277 120 72109 72109 24108 86379 86360 24108 86381 86372 24108 24108 Ballast Product Code Ballast Description Sign Ballasts F96T8/WM 2 2 2 2 2 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Multivolt Instant Start Magnetic - Standard Instant Start Magnetic - Standard Instant Start Electronic - Multivolt Instant Start Magnetic - Standard Instant Start Magnetic - Standard Instant Start Electronic - Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - High Efficiency Multivolt Instant Start Electronic - Multivolt Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Fluorescent Ballast Long Description # of Lamp Type Lamps Voltage Fluorescent Ballast Type T12 Fluorescent Ballasts F96T8/HO 120-277 120-277 120-277 277 120 120-277 277 120 120-277 120-277 Prod Code Page No T5 Fluorescent Ballasts F96T8 2 2 2 2 2 1 1 1 2 1 Ballast Product Code Ballast Description T8 Fluorescent Ballasts # of Lamp Type Lamps Voltage Fluorescent Ballast Type Quick Reference Guides gelighting.com Quick reference lamp to ballast selection guide (cont.) Compact Fluorescent Lamps CFT5W/2P CFT7W/2P CFT9W/2P CFTR13W/ GX24q CFTR26W/ 2P CFTR26W/ GX24q CFTR42W/ GX24q FC12T5 FT24W/ 2G11 FT39W/4P 87634 87634 87634 71430 71429 71430 71429 71434 71433 71430 71429 71434 71433 GEM1CF579PH277 GEM1CF579PH277 GEM1CF579PH277 GEC213-MVPS-3W GEC213-MVPS-XX GEC213-MVPS-3W GEC213-MVPS-XX GEC218-MVPS-3W GEC218-MVPS-XX GEC213-MVPS-3W GEC213-MVPS-XX GEC218-MVPS-3W GEC218-MVPS-XX 1 - CFT579Q9W/G23 Preheat 277 (4205F2P) 1 - CFT579Q9W/G23 Preheat 277 (4205F2P) 1 - CFT579Q9W/G23 Preheat 277 (4205F2P) 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit 2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS 2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit 2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS 128 128 128 123 123 123 123 123 123 123 123 123 123 2 2 277 Magnetic - Preheat 120-277 Electronic - Program / Rapid Start 87700 47506 GEM2CF24PH277 C242UNVBES-IP 129 124 2 120-277 Electronic - Program / Rapid Start 71445 GEC226-MVPS-3W 2 120-277 Electronic - Program / Rapid Start 71444 GEC226-MVPS-XX 1 120-277 Electronic - Program / Rapid Start 71445 GEC226-MVPS-3W 1 2 120-277 Electronic - Program / Rapid Start 120-277 Electronic - Program / Rapid Start 71444 47506 GEC226-MVPS-XX C242UNVBES-IP 1 120-277 Electronic - Program / Rapid Start 71445 GEC226-MVPS-3W 1 120-277 Electronic - Program / Rapid Start 71444 GEC226-MVPS-XX 1 120-277 Electronic - Program / Rapid Start 71445 GEC226-MVPS-3W 1 2 1 2 120-277 120-277 120-277 120-277 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start 71444 47506 47506 47506 GEC226-MVPS-XX C242UNVBES-IP C242UNVBES-IP C242UNVBES-IP 2 - CFQ26W/G24d Preheat 277 (4226PBES) 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 1&1 2 1 2 120-277 120-277 120-277 120-277 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start 47506 47534 47534 47506 C242UNVBES-IP B224PUNV-COG1C B224PUNV-COG1C C242UNVBES-IP 2 120-277 Electronic - Program / Rapid Start 71445 GEC226-MVPS-3W 2 2 1 4 3 2 2 2 2 2 2 2 1 1 1 1 1 1 3 3 2 2 2 2 2 2 1 1 1 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120 120 120-277 120-277 120-277 120-277 120-277 120-277 277 120 120-277 277 277 120 120 120 120-277 277 120 71444 47534 47534 99649 99649 47540 47542 47506 99651 99649 97498 87623 47534 47534 47540 47542 99651 99649 80691 80690 80683 80681 80691 80680 80690 87625 80683 80681 80680 GEC226-MVPS-XX B224PUNV-COG1C B224PUNV-COG1C GE454MVPS90-E GE454MVPS90-E B239PUNV-DOG1C B254PUNV-DGE1C C242UNVBES-IP GE254MVPS90-F GE454MVPS90-E GE240RS120 GEM2FT36RS120 B224PUNV-COG1C B224PUNV-COG1C B239PUNV-DOG1C B254PUNV-DGE1C GE254MVPS90-F GE454MVPS90-E C340SI277RH-IP C340SI120RH-IP C240PUNVHP-B-IP C240SI277RH-IP C340SI277RH-IP C240SI120RH-IP C340SI120RH-IP GEM2FT40RS120 C240PUNVHP-B-IP C240SI277RH-IP C240SI120RH-IP Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Magnetic - Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Standard Instant Start Electronic - Standard Instant Start Magnetic - Rapid Start Electronic - Program / Rapid Start Electronic - Standard Instant Start Electronic - Standard Instant Start 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2 - F24T5HO PRS UNV 50/60 Hz 2 - F24T5HO PRS UNV 50/60 Hz 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V ProLine® PS 2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V ProLine® PS 2 - F24T5HO PRS UNV 50/60 Hz 2 - F24T5HO PRS UNV 50/60 Hz 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 - F39T5HO PRS UNV 50/60 Hz 2 - F54T5HO PRS UNV 50/60 Hz 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 6 - F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12 2 - FT36W/2G11 RS 120 (4150P) 2 - F24T5HO PRS UNV 50/60 Hz 2 - F24T5HO PRS UNV 50/60 Hz 2 - F39T5HO PRS UNV 50/60 Hz 2 - F54T5HO PRS UNV 50/60 Hz 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 3 - FT40W/2G11 IS 277 3 - FT40W/2G11 IS 120 2 or 1 - FT40W2G11 PS UNV 2 - FT40W/2G11 IS 277 3 - FT40W/2G11 IS 277 2 - FT40W/2G11 IS 120 3 - FT40W/2G11 IS 120 2 - FT40W/2G11RS RS 120 (4152P) 2 or 1 - FT40W2G11 PS UNV 2 - FT40W/2G11 IS 277 2 - FT40W/2G11 IS 120 Compact Fluorescent Lamps FT50W/ 2G11 FT55W/ 2G11 4 3 2 2 1 1 4 3 2 2 1 1 1 1 1 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start 99649 99649 99651 99649 99651 99649 99649 99649 99651 99649 47542 47542 47506 99651 99649 GE454MVPS90-E GE454MVPS90-E GE254MVPS90-F GE454MVPS90-E GE254MVPS90-F GE454MVPS90-E GE454MVPS90-E GE454MVPS90-E GE254MVPS90-F GE454MVPS90-E B254PUNV-DGE1C B254PUNV-DGE1C C242UNVBES-IP GE254MVPS90-F GE454MVPS90-E 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 2 - F54T5HO PRS UNV 50/60 Hz 2 - F54T5HO PRS UNV 50/60 Hz 2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs 2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can 4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can 81 81 80 81 80 81 81 81 80 81 80 80 124 80 81 124 124 124 124 124 124 124 124 124 124 124 123 123 124 124 124 79 79 81 81 79 80 124 80 81 85 130 79 79 79 80 80 81 127 126 125 126 127 125 126 130 125 126 125 See page 195 for warranty information. See page 195 for warranty information. 33 HID Electromagnetic Ballasts 32 Magnetic - Preheat Magnetic - Preheat Magnetic - Preheat Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Electronic - Program / Rapid Start Prod Code Page No HID Electronic Ballasts FT40W/4P 277 277 277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120-277 Fluorescent Ballast Long Description Compact Fluorescent Ballasts FT24W/4P 1 1 1 2 2 1 1 2 2 1 1 1 1 Ballast Product Code Ballast Description Sign Ballasts FC9T5 FC9T5 & FC12T5 FT24W/ 2G10 Fluorescent Ballast Long Description # of Lamp Type Lamps Voltage Fluorescent Ballast Type T12 Fluorescent Ballasts CFTR32W/ GX24q Prod Code Page No T5 Fluorescent Ballasts CFTR18W/ GX24q Ballast Product Code Ballast Description T8 Fluorescent Ballasts # of Lamp Type Lamps Voltage Fluorescent Ballast Type Quick Reference Guides gelighting.com Quick reference lamp to ballast selection guide (cont.) Lamp Type Use with ANSI Lamp Types Wattage PC New GE Description Circuit Type 120/208/240/277 120/208/240/277 120/480 120/208/240/277 120/277 120/277 120/480 120/208/240/277 120/480 120/208/240/277 120/277 120/480 120/208/240/277 120/480 120/208/240/277 120/480 120/208/240/277 120/480 120/208/240/277 120/480 120/208/240/277 120/277 120/208/240/277/480 120/208/240/277 120/277 120/208/240/277/480 120/208/240/277/480 120/208/240/277 120/277 120/277 120/480 120/208/240/277/480 120/208/240/277 120/480 120/208/240/277/480 120/208/240/277 120/480 120/208/240/277 120 120 120 120 120 120 120-277 120 120 120 120-277 120 120-277 120-277 120-277 120-277 120-277 120-277 120-277 120/480 120/208/240/277 120/480 120/208/240/277 208-277 208-277 208-277 208-277 120/480 120/208/240/277 208-277 208-277 120/480 120/208/240/277 208-277 208-277 208-277 208-277 120/480 120/208/240/277 120/277/347 6MFD 280V 6MFD 280V 8MFD 280V 8MFD 280V N/A N/A 8MFD 280V 8MFD 280V 12MFD 280V 12MFD 280V N/A 12MFD 280V 12MFD 280V 12MFD 280V 12MFD 280V 16MFD 280V 16MFD 280V 16MFD 280V 16MFD 280V 16MFD 280V 16MFD 280V N/A 10MFD 400V 10MFD 400V N/A 15MFD 400V 15MFD 400V 15MFD 400V N/A N/A 24MFD 400V 24MFD 400V 24MFD 400V 24MFD 480V 24MFD 480V 24MFD 480V 32MFD 525V 32MFD 525V N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 10MFD 400V 10MFD 400V 10MFD 400V 10MFD 400V N/A N/A N/A N/A 15MFD 400V 15MFD 400V N/A N/A 15MFD 400V 15MFD 400V N/A N/A N/A N/A 21MFD 345V 21MFD 345V 21MFD 345V MH350-1A MH350-1A MH350-1A MH350-1A N/A N/A MH350-1A MH350-1A MH350-1A MH350-1A N/A MH350-1A MH350-1A MH350-1A MH350-1A MH350-1A MH350-1A MH350-1A MH350-1A MH350-1A MH350-1A N/A 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A MH350-1A MH350-1A MH350-1A MH350-1A N/A N/A N/A N/A MH350-1A MH350-1A N/A N/A MH350-1A N/A N/A N/A N/A MH350-1A MH350-1A MH350-1A 144 144 145 144 174 174 145 144 146 145 175 146 145 146 145 147 146 147 146 147 146 175 147 148 176 149 150 149 176 177 151 151 152 152 153 153 154 135 135 136 136 136 136 137 136 136 136 137 136 137 137 137 137 138 138 138 155 155 155 155 139 139 139 139 156 156 139 139 156 156 139 139 139 139 157 157 158 See page 195 for warranty information. PC New GE Description Circuit Type Frame Size High Intensity Discharge (HID) Lamps Pulse Start (cont) High Pressure Sodium Mercury M154 M154 M154 M154 M154 CMH350 CMH350 M131 M131 M131 M131 CMH400 CMH400 M135 M135 M135 M135 M155 M155 M155 M155 M149 M149 M141 M141 S68 S62 S62 S62 S62 S54 S54 S55 S55 S55 S50 S50 S51 S51 S51 S52 S52 S52 H39 H39 H37 H37 H37 H33 H33 H33 H36 H36 H36 320 320 320 320 320 350 350 350 350 350 350 400 400 400 400 400 400 400 400 400 400 750 750 1000 1000 50 70 70 70 70 100 100 150 150 150 250 250 400 400 400 1000 1000 1000 175 175 250 250 250 400 400 400 1000 1000 1000 29377 89646 86952 86959 86968 29377 89646 29377 89646 86984 86984 29377 89646 29377 89646 86999 87008 29377 89646 87008 86999 46936 46934 72282 72281 87152 86596 86605 86456 86587 87068 87074 86606 87087 87094 87214 87121 87198 87215 87164 87048 87218 87056 87210 86741 87211 87212 86765 86803 72300 72149 86650 87213 86655 GE-MH-250-400-MA eHID GEMH250-400MV50 eHID Dim GEP32048TAC4-5 CWA GEP320MLTAC4-5 CWA GEP320TRIAC4-5 CWA GE-MH-250-400-MA eHID GEMH250-400MV50 eHID Dim GE-MH-250-400-MA eHID GEMH250-400MV50 eHID Dim GEP350277RCE-5 RX-NPF GEP350MLTAC4-5 CWA GE-MH-250-400-MA eHID GEMH250-400MV50 eHID Dim GE-MH-250-400-MA eHID GEMH250-400MV50 eHID Dim GEP40048TAC4-5 CWA GEP400MLTAC4-5 CWA GE-MH-250-400-MA eHID GEMH250-400MV50 eHID Dim GEP400MLTAC4-5 CWA GEP40048TAC4-5 CWA GEP75048TAC5-5 CWA GEP750MLTAC5-5 CWA GEP1000ML5AC5-5 CWA GEP1000MLTAC5-5 CWA GES50MLTLC3D-5 HX-HPF 12210237CTC000I HX-HPF 1233142U000I R-HPF, R-NPF GES7048TLC3D-5 HX-HPF GES70MLTLC3D-5 HX-HPF GES10048TLC3D-5 HX-HPF GES100MLTLC3D-5 HX-HPF 1233154U000I R-NPF GES15048TLC3D-5 HX-HPF GES150MLTLC3D-5 HX-HPF GES250ML5AC4-5 CWA GES250MLTAC4-5 CWA GES40048TAC4-5 CWA GES400ML5AC4-5 CWA GES400MLTAC4-5 CWA GES100048TAC5-5 CWA GES1000ML5AC5-5 CWA GES1000MLTAC5-5 CWA GEM175ML5AC3-5 CWA GEM175MLTAC3-5 CWA GEM250ML5AC3-5 CWA GEM250ML5AC4-5 CWA GEM250MLTAC3-5 CWA GEM40048TAC4-5 CWA GEM400ML5AA4-5 CWA GEM400MLTAA4-5 CWA GEM100048TAC5-5 CWA GEM1000ML5AC5-5 CWA GEM1000MLTAC5-5 CWA 4.25x4.75 4.25x4.75 4.25x4.75 3.75x4.5 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x6.00 4.25x6.00 4.25x6.00 4.25x6.00 3x4 F-Can 2.81x3.94 3x4 3x4 3x4 3x4 2.81x3.94 3x4 3x4 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x4.75 4.25x6.00 4.25x6.00 4.25x6.00 3x4 3x4 3x4 4.25x4.75 3x4 4.25x4.75 4.25x4.75 4.25x4.75 4.25x6.00 4.25x6.00 4.25x6.00 Voltage Cap. Ignitor 208-277 208-277 120/480 120/208/240/277 120/277/347 208-277 208-277 208-277 208-277 277 120/208/240/277 208-277 208-277 208-277 208-277 120/480 120/208/240/277 208-277 208-277 120/208/240/277 120/480 120/480 120/208/240/277 120/208/240/277/480 120/208/240/277 120/208/240/277 120/277 120 120/480 120/208/240/277 120/480 120/208/240/277 120 120/480 120/208/240/277 120/208/240/277/480 120/208/240/277 120/480 120/208/240/277/480 120/208/240/277 120/480 120/208/240/277/480 120/208/240/277 120/208/240/277/480 120/208/240/277 120/208/240/277/480 120/208/240/277/480 120/208/240/277 120/480 120/208/240/277/480 120/208/240/277 120/480 120/208/240/277/480 120/208/240/277 N/A N/A 21MFD 345V 21MFD 345V 21MFD 345V N/A N/A N/A N/A 22.5MFD 345V 22.5MFD 345V N/A N/A N/A N/A 24MFD 400V 24MFD 400V N/A N/A 24MFD 400V 24MFD 400V 24MFD 400V 24MFD 400V 24MFD 480V 24MFD 480V 5MFD 280V N/A N/A N/A MH350-1A MH350-1A MH350-1A N/A N/A N/A N/A MH350-1A MH350-1A N/A N/A N/A N/A MH350-1A MH350-1A N/A N/A MH350-1A MH350-1A MH750-1B MH750-1B HPS1000-4B HPS1000-4B HPS150-3A N/A 7MFD 300V 7MFD 300V 10MFD 280V 10MFD 280V HPS150-3A HPS150-3A 14MFD 280V 14MFD 280V 35MFD 240V 35MFD 240V 55MFD 240V 55MFD 240V 55MFD 240V 26MFD 525V 26MFD 525V 26MFD 525V 10MFD 400V 10MFD 400V 15MFD 400V 15MFD 400V 15MFD 400V 24MFD 400V 24MFD 400V 24MFD 400V 24MFD 480V 24MFD 480V 24MFD 480V HPS150-3A HPS150-3A HPS150-3A HPS400-3A HPS400-3A HPS400-3A HPS400-3A HPS400-3A HPS24 HPS1000-4B HPS1000-4B Prod Code Page No 139 139 157 157 158 139 139 139 139 158 158 139 139 139 139 159 159 139 139 159 159 160 160 161 161 162 178 178 163 162 164 163 179 165 164 166 166 168 167 167 168 169 169 147 148 149 150 149 151 150 151 152 152 153 See page 195 for warranty information. 35 HID Electromagnetic Ballasts 3x4 3x4 3x4 3x4 F-Can F-Can 3x4 3x4 3x4 4.25x5.75 F-Can 3x4 4.25x5.75 3x4 4.25x5.75 3x4 3x4 3x4 3x4 3x4 3x4 F-Can 3x4 3x4 F-Can 3x4 4.25x4.75 3x4 F-Can F-Can 4.25x4.75 4.25x4.75 4.25x4.75 4.25x6.00 4.25x6.00 4.25x6.00 4.25x6.00 4.25x6.00 3.7x1.6x1.0 Side Lead 3.7x3.0x1.2 Side Lead 3.7x3.0x1.2 Side Lead 3.7x3.0x1.2 Side Lead 3.7x3.0x1.2 Side Lead 3.7x3.0x1.2 Side Lead 7.3x2.6x2.2 BE w/Studs 3.7x3.0x1.2 Side Lead 3.7x3.0x1.2 Side Lead 3.7x3.0x1.2 Side Lead 7.3x2.6x2.2 BE w/Studs 3.7x3.0x1.2 Side Lead 7.3x2.6x2.2 BE w/Studs 7.3x2.6x2.2 BE w/Studs 7.3x2.6x2.2 BE w/Studs 7.3x2.6x2.2 BE w/Studs 7.3x2.6x2.2 BE w/Studs 7.3x2.6x2.2 BE w/Studs 7.3x2.6x2.2 BE w/Studs 3x4 3x4 3x4 3x4 Use with ANSI Lamp Types Wattage HID Electronic Ballasts HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA CWA eHID eHID eHID eHID eHID eHID eHID eHID eHID eHID eHID eHID eHID eHID eHID eHID eHID eHID eHID CWA CWA CWA CWA eHID eHID Dim eHID eHID Dim CWA CWA eHID eHID Dim CWA CWA eHID eHID Dim eHID eHID Dim CWA CWA CWA Lamp Type Compact Fluorescent Ballasts GEM50MLTLC3D-5 GEM50MLTLC3D-5 GEM7048TLC3D-5 GEM70MLTLC3D-5 11210277CTC000C 11210506CTC000C GEM7048TLC3D-5 GEM70MLTLC3D-5 GEM10048TLC3D-5 GEM100MLTLC3D-5 11210239CTC000I GEM10048TLC3D-5 GEM100MLTLC3D-5 GEM10048TLC3D-5 GEM100MLTLC3D-5 GEM15048TLC3D-5 GEM150MLTLC3D-5 GEM15048TLC3D-5 GEM150MLTLC3D-5 GEM15048TLC3D-5 GEM150MLTLC3D-5 1110245SCTC000I GEM175ML5AC3-5 GEM175MLTAC3-5 1110246CTC000C GEM250ML5AC3-5 GEM250ML5AC4-5 GEM250MLTAC3-5 1110-247SC-TC 1111-247SCTC000I GEM40048TAC4-5 GEM400ML5AA4-5 GEM400MLTAA4-5 GEM100048TAC5-5 GEM1000ML5AC5-5 GEM1000MLTAC5-5 GEM150048TAC5-5 GEM1500MLTAC5-5 GEMH20-MLF-120 GEMH39-MSF-120 GEMH50-MSF-120 GEMH50-MSF-120 GEMH50-MSF-120 GEMH70-MSF-120 GEMH70-SLJ-MV GEMH70-MSF-120 GEMH70-MSF-120 GEMH70-MSF-120 GEMH70-SLJ-MV GEMH70-MSF-120 GEMH70-SLJ-MV GEMH100-SLJ-MV GEMH100-SLJ-MV GEMH100-SLJ-MV GEMH150-SLJ-MV GEMH150-SLJ-MV GEMH150-SLJ-MV GEP17548TAC3-5 GEP175MLTAC3-5 GEP17548TAC3-5 GEP175MLTAC3-5 GE-MH-250-400-MA GEMH250-400MV50 GE-MH-250-400-MA GEMH250-400MV50 GEP25048TAC4-5 GEP250MLTAC4-5 GE-MH-250-400-MA GEMH250-400MV50 GEP25048TAC4-5 GEP250MLTAC4-5 GE-MH-250-400-MA GEMH250-400MV50 GE-MH-250-400-MA GEMH250-400MV50 GEP32048TAC4-5 GEP320MLTAC4-5 GEP320TRIAC4-5 Prod Code Page No Sign Ballasts 34 86824 86824 86839 86847 86576 86578 86839 86847 86667 86675 86574 86667 86675 86667 86675 86711 86718 86711 86718 86711 86718 86563 87210 86741 86564 87211 87212 86765 42670 80728 86803 72300 72149 86650 87213 86655 86693 86698 87490 87501 87516 87516 87516 87531 87546 87531 87531 87531 87546 87531 87546 87561 87561 87561 87576 87576 87576 86876 86885 86876 86885 29377 89646 29377 89646 86926 86935 29377 89646 86926 86935 29377 89646 29377 89646 86952 86959 86968 Ignitor T12 Fluorescent Ballasts Pulse Start 50 50 70 70 70 70 70 70 100 100 100 100 100 100 100 150 150 150 150 150 150 175 175 175 250 250 250 250 400 400 400 400 400 1000 1000 1000 1500 1500 20 39 50 50 50 70 70 70 70 70 70 70 70 100 100 100 150 150 150 175 175 175 175 250 250 250 250 250 250 250 250 250 250 320 320 320 320 320 320 320 Cap. T5 Fluorescent Ballasts Metal Halide M110 M148 M143 M143 M85 M98 M98 M98 M140 M140 M90 M90 M90 M92 M92 M102 M102 M107 M107 M142 M142 M57 M57 M57 M58 M58 M58 M58 M59 M59 M59 M59 M59 M47 M47 M47 M48 M48 M156 M130 C148 M110 M148 C143 C143 M139 M139 M143 M143 M98 M98 C140 M140 M90 C142 M102 M142 M137 M137 M152 M152 CMH250 CMH250 M138 M138 M138 M138 M153 M153 M153 M153 CMH320 CMH320 M132 M132 M132 M132 M132 Voltage T8 Fluorescent Ballasts High Intensity Discharge (HID) Lamps Frame Size Quick Reference Guides gelighting.com GE Fluorescent Ballast Types GE introduced the first fluorescent ballast more than 60 years ago. Today we are providing high-frequency electronic ballasts for almost every fluorescent application. UltraMax® A family of high-efficiency GE T8 instant-start electronic linear fluorescent ballasts designed to optimize GE’s T8 Ultra lamps for optimal system energy savings. UltraMax® ballasts have a low lamp current crest factor and virtually “read” and adapt to incoming voltage from 108V to 305V. Other features include UL Type CC Anti-Arc Rating and anti-striation control to eliminate lamp striations and spiraling. These ballasts are offered in ballast factors: low wattage (.77), normal light (.87), normal-high (N+) (1.0) and high (>1.15). ProLine® Offered in dedicated or multi-volt (120-277V), these high-performance T8 instant-start ballasts also meet minimum efficiency requirements as established with the NEMA Premium® ballast program. These ballasts are offered in ballast factors: low wattage (.77), normal light (.87), and high (>1.15). Ballast Life GE electronic ballasts are designed and manufactured to an average life expectancy of 60,000 hours of operation at maximum rated case temperatures. As a rule of thumb, ballast life is doubled for every 10C reduction in ballast case temperature. However there are other variables such as transients, voltage sags and swells, ambient temperature, etc., which affect ballast life as well. Instant Start vs. Rapid Start Sockets When using programmed start or dimming ballasts in fixtures, sockets must be 2-pin rapid start type. Fixtures with T8 instant start ballasts must use jumpered rapid start sockets or shunted lamp holders (internal to the lamp holder) that bridge the lamp bi-pins together into one contact on each side of the lamp. If retrofitting from a instant start ballast fixture with shunted sockets to a dimming or programmed start ballast, rapid start type sockets must be used to properly start lamps and maintain rated lamp life. Programmed Start Programmed Start electronic ballasts have a lamp starting method that preheats lamp filaments while not allowing the lamp to ignite and then applies an open circuit voltage (OCV) to start the lamp. Use Programmed Start ballasts to ensure long lamp life when turning lamps on and off more than five times in a day or in conjunction with any automatic light control or sensor. This type of starting circuit keeps lamp-end blackening to a minimum and improves lamp life performance, especially in applications where the lamps are frequently switched on and off. Compact Fluorescent Ballasts GE Ballast Electronic nomenclature G E - 2 3 2 - M V P S - N - 4 2 T See page 195 for warranty information. See page 195 for warranty information. Ultra-Hi Efficiency 84T, 42T, T = 840, 420 qty OEM pallet packs A, D, E, F = Can sizes BES = Bottom exit with studs SE = Dual – side & bottom exit 3W = 3 way mounting kit 37 HID Electromagnetic Ballasts IS = Instant Start, Lamp Watts standard if not shown (Primary Lamp) RS = Rapid Start T8 = 32-four foot, PS = Program Start 59-eight foot Maximum T12 = 40-four foot, number 60-eight foot of lamps Ballast Factor supported 120 = 120 volt L =Low Power for by this ballast 277 = 277 volt MAX savings – 1, 2, 3, 4, 6 MAX or MV = N = Normal for 120 – 277V New Fixtures H = High Power, Hi-Light, Hi-Bay GE Ballast GE = LFL GEC = CFL 36 HID Electronic Ballasts UltraStart® UltraStart® is a family of high-efficiency GE Programmed Start electronic linear fluorescent ballasts that also exceed NEMA Premium® ballast efficiency requirements but are designed to optimize GE’s T8 Ultra lamps in frequently switched applications. Instant start ballasts provide 7,000-13,000 starts before 50% lamp failure. UltraStart® provides greater than 100,000 starts before 50% lamp failure. UltraStart® ballasts have the same energy savings and convenience of instant start ballasts but with the long lamp life of a programmed start ballast. These ballasts are offered in ballast factors: programmed start x-low wattage (XL) (.60), low wattage (.71), normal light (.87), and high (>1.15). Sign Ballasts GE revolutionizes lighting again with breakthrough technology. Our patented UltraMax® instant-start and UltraStart® programmed start electronic ballasts transform the power of light into efficiency and savings from store shelves to the installation site. The foundation of the “Ultra” family of ballasts starts with its high efficiency ratings. High efficiency ballasts are a minimum of 90% efficiency with some ballasts nearly 95% efficient which means the ballast only consumes 5-10% of the total system power. These high efficiency ballasts exceed minimum high efficiency standards as established by almost all energy advocate groups, utility rebate programs and the NEMA Premium® ballast program. The ballasts are marked with the Ultra brand as well as the NEMA Premium® ballast mark. These ballasts have multi-voltage control (MVC), which automatically adjusts to handle voltage from 120V through 277V. That cuts the ballast models you need to stock from 40 down to 13, which can dramatically reduce inventory carrying costs. UltraMax® ballasts have ArcGuard Protection, too, with a UL Type CC Anti-Arc Rating. Plus, they’re ultra-lamp-friendly, with a low lamp current crest factor of 1.4 for optimal lamp performance. Both UltraMax® and UltraStart® have anti-striation control for better light quality with no lamp striations (spiraling). And the small, low-profile design of these ballasts makes retrofits effortless at the job site. Also unique to our programmed start UltraStart® ballasts is parallel lamp operation which ensures if one lamp fails the others remain on, and quick starting times of less than 700 milliseconds which is necessary in avoiding delays with automatic sensors. Date Codes GE electronic ballast manufacturing date codes are located on the upper right-hand corner of the label. The code lists the month, year and day of manufacture. A typical code is C06-073, where the month is listed as A (January), B (February), C (March) (as in this code) followed by the year 06 (2006) and the date of manufacture 073 (the 73rd day of 2006). T12 Fluorescent Ballasts With our UltraMax® and UltraStart® ballasts, we are bringing you the future in ballast performance. The most common fluorescent ballast is the instant start and is used typically in long 3 to 10-hour lamp cycle applications. These ballasts are energy efficient and can deliver up to 20% to greater than 40% energy savings when installed with energy-efficient lamps in building retrofits. These ballasts deliver >550 open circuit volts when starting lamps and operate lamps at high frequencies which offers flicker-free operation and better lamp efficiencies. The ballasts are significantly quieter than conventional magnetic ballasts and are backed by GE’s ultra system 5-year ballast limited warranty and extended lamp warranties. T5 Fluorescent Ballasts A comprehensive range of solutions…from GE, the name you trust. Ballast Date Codes T8 Fluorescent Ballasts Understanding T8 Fluorescent Ballasts Electronic Instant Start Quick Reference Guides gelighting.com UltraMax® Instant Start Multi-Voltage High-Efficiency T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps UltraMax® Instant Start Multi-Voltage High-Efficiency ® General characteristics Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Low Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Wiring diagram – LFL 1A – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue Red White Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 72258 Pallet Pack DIY Pack IP Pack System Watts 25 25 24 24 22 22 21 21 21 21 15 15 12 12 Safety and performance 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 0.87 in (22.00 mm) 0.3 in (7.92 mm) 1.06 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 34 in (864 mm) 41 in (1041 mm) 25 in (635 mm) UL Type HL Ballast Efficacy Factor 3.08 3.08 3.20 3.20 3.50 3.50 FCC – CLASS A Non-Consumer Electrical characteristics Supply Current Frequency ® 1 – F32T8 120 to 277 “N” .87 BF UltraMax General characteristics Order information 10 Pack 49775 UL Class P Power Factor% (>=) 99 94 99 93 99 93 99 92 99 92 99 88 86 99 cUL Listed Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Type CC UL Listed THD% (<=) 10 10 10 10 10 10 10 20 10 20 12 25 13 27 Min. Starting Temp (°F/°C) -22 / -30 -22 / -30 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 • Energy-saving high-efficiency instant-start electronic ballast (>90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Active Current Regulation regulates the output to each lamp with individual lamp inverter modules • Anti-striation control for better light quality, with no striations • Lamp frequency >70kHz Order information DIY Pack 72260 (replaces 23939) IP Pack UL Type 1 Outdoor NRCan UL Type HL Ballast Efficacy Factor 1.55 1.57 2.80 2.87 1.61 1.64 2.94 2.94 1.74 1.76 3.19 3.19 FCC – CLASS A Non-Consumer Power Factor% (>=) 99 98 96 99 99 98 99 96 99 97 99 96 RoHS Compliant Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Class P cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 UL Type CC Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 UL Listed 72262 – GE232MAX-L/ULTRA (replaces 49707) UltraMax® Instant Start Multi-Voltage High-Efficiency 2 or 1 – F32T8 120 to 277 “L” .77 BF UltraMax® 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 0.87 in (22.00 mm) 0.3 in (7.92 mm) 1.06 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 41 in (1041 mm) 25 in (635 mm) 34 in (864 mm) Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Low Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Wiring diagram LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue White Red Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 72262 • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Active Current Regulation regulates the output to each lamp with individual lamp inverter modules • Anti-striation control for better light quality, with no striations • Lamp frequency >70kHz Pallet Pack 72256 (replaces 47546) DIY Pack IP Pack 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 0.87 in (22.00 mm) 0.3 in (7.92 mm) 1.06 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 34 in (864 mm) 25 in (635 mm) 41 in (1041 mm) Specifications by lamp and wattage Nom. Line Current 0.24 A 0.11 A 0.23 A 0.10 A 0.22 A 0.10 A 0.22 A 0.10 A 0.09 A 0.19 A 0.14 A 0.07 A 0.12 A 0.06 A UL Type 1 Outdoor UL Type CC System Ballast Factor 0.87 0.87 0.87 0.87 0.87 0.87 UL Type HL Ballast Efficacy Factor 3.10 3.10 3.22 3.22 3.48 3.48 FCC – CLASS A Non-Consumer Power Factor% (>=) 99 98 99 98 99 98 99 94 93 99 99 90 99 88 UL Class P cUL Listed Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Listed THD% (<=) 10 10 10 10 10 10 10 17 18 10 10 22 11 25 Min. Starting Temp (°F/°C) -22 / -30 -22 / -30 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 Lamp # of Lamps Line Volts System Watts 2 120 51 2 277 50 1 277 29 F32T8 1 120 28 2 120 47 2 277 47 1 277 27 F32T8/WM 1 120 26 2 120 43 2 277 43 1 277 25 F28T8 1 120 24 2 120 42 2 277 42 1 120 24 F25T12 1 277 24 Other compatible lamps: F25T8, FE15T8, F17T8, F32T8/25W Nom. Line Current 0.42 A 0.19 A 0.11 A 0.24 A 0.40 A 0.18 A 0.11 A 0.22 A 0.38 A 0.18 A 0.10 A 0.21 A 0.36 A 0.16 A 0.21 A 0.10 A System Ballast Factor 0.78 0.78 0.77 0.77 0.77 0.77 0.77 0.77 0.74 0.74 0.77 0.77 Ballast Efficacy Factor 1.53 1.56 2.65 2.75 1.64 1.63 2.85 2.96 1.72 1.72 3.08 3.20 Power Factor% (>=) 99 97 93 99 99 97 93 99 99 97 92 99 99 96 99 91 Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 19 11 20 Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant Safety and performance See page 195 for warranty information. See page 195 for warranty information. UL Type 1 Outdoor NRCan UL Type CC RoHS Compliant UL Type HL FCC – CLASS A Non-Consumer UL Class P cUL Listed UL Listed 39 HID Electromagnetic Ballasts 38 Safety and performance System Ballast Factor 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 HID Electronic Ballasts Safety and performance # of Lamps Line Volts System Watts Nom. Line Current 2 120 74 0.62 A 2 277 73 0.27 A 1 277 41 0.16 A F32T8 1 120 40 0.36 A 2 120 71 0.59 A 2 277 70 0.26 A 1 120 39 0.34 A F32T8/WM 1 277 39 0.15 A 2 120 66 0.58 A 2 277 65 0.26 A 1 120 36 0.32 A F28T8 1 277 36 0.15 A Other compatible lamps: FE15T8, F40T8, F25T8, F25T12, F17T8, F32T8/25W Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage System Watts 28 28 27 27 25 25 25 25 24 23 17 17 14 14 IP Pack Compact Fluorescent Ballasts 50 Hz/60 Hz # of Lamps Line Volts 1 120 F32T8 1 277 1 120 F32T8/WM 1 277 1 120 F28T8 1 277 1 120 F25T12 1 277 1 277 F25T8 1 120 1 120 F17T8 1 277 1 120 FE15T8 1 277 Other compatible lamps: F32T8/25W DIY Pack General characteristics Wiring diagram – LFL 1A – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue Electrical characteristics Lamp Pallet Pack 47548 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 25 in (635 mm) 34 in (864 mm) 41 in (1041 mm) RoHS Compliant Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Pallet Pack 50 Hz/60 Hz 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) Sign Ballasts UltraMax® Instant Start Multi-Voltage High-Efficiency 10 Pack 72259 Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black White Blue Red Specifications by lamp and wattage System Ballast Factor 0.77 0.77 0.77 0.77 0.77 0.77 72259 – GE-132MAX-N/ULTRA (replaces 49771) Supply Current Frequency Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) High Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Lamp Nom. Line Current 0.22 A 0.10 A 0.21 A 0.09 A 0.20 A 0.09 A 0.18 A 0.08 A 0.19 A 0.09 A 0.13 A 0.07 A 0.10 A 0.05 A UL Type 1 Outdoor Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info General characteristics T12 Fluorescent Ballasts # of Lamps Line Volts 1 120 F32T8 1 277 1 120 F32T8/WM 1 277 1 120 F28T8 1 277 1 120 F25T8 1 277 1 120 F25T12 1 277 1 120 F17T8 1 277 1 120 FE15T8 1 277 Other compatible lamps: F32T8/25W 2 or 1 – F32T8 120 to 277 “H” 1.15 BF UltraMax® Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp UltraMax® Instant Start Multi-Voltage High-Efficiency • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Active Current Regulation regulates the output to each lamp with individual lamp inverter modules • Anti-striation control for better light quality, with no striations T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 49775 – GE232MAX-H/ULTRA T8 Fluorescent Ballasts • Energy-saving high-efficiency instant-start electronic ballast (>90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Active Current Regulation regulates the output to each lamp with individual lamp inverter modules • Anti-striation control for better light quality, with no striations • Lamp frequency >70kHz 72258 – GE132MAX-L/ULTRA (replaces 49706) 1 – F32T8 120 to 277 “L” .77 BF UltraMax UltraMax® Instant Start Multi-Voltage High-Efficiency T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps Quick Reference Guides gelighting.com UltraMax® Instant Start Multi-Voltage High-Efficiency T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps 72266 – GE232MAX-N/ULTRA (replaces 49772) ® 2 or 1 – F32T8 120 to 277 “N” .87 BF UltraMax General characteristics Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected 50 Hz/60 Hz Order information 10 Pack 72266 Pallet Pack 72267 (replaces 31052) DIY Pack 72268 (replaces 23940) IP Pack 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 0.87 in (22.00 mm) 0.3 in (7.92 mm) 1.06 lbs Side 18 ft 18 AWG Length (± 1 in) 41 in (1041 mm) 25 in (635 mm) 25 in (635 mm) 34 in (864 mm) Safety and performance UL Type 1 Outdoor RoHS Compliant System Ballast Factor 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 UL Type HL Ballast Efficacy Factor 1.61 1.64 2.80 2.80 1.64 1.67 3.00 3.00 1.77 1.81 3.22 3.22 Electrical characteristics ® General characteristics Order information 10 Pack 71714 UL Class P Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 16 10 22 UL Type CC NRCan Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Active Current Regulation regulates the output to each lamp with individual lamp inverter modules • Anti-striation control for better light quality, with no striations Dimensions 50 Hz/60 Hz Order information Pallet Pack DIY Pack IP Pack Wiring diagram LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue Red White IP Pack RoHS Compliant UL Type CC Ballast Efficacy Factor 1.59 1.61 2.77 2.81 1.67 1.68 2.91 2.96 1.79 1.75 3.11 3.02 1.74 1.75 3.11 3.05 UL Type HL NRCan Power Factor% (>=) 99 98 96 99 99 98 96 99 99 98 99 96 99 98 99 96 UL Type 1 Outdoor UL Type HL 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 34 in (864 mm) 41 in (1041 mm) 25 in (635 mm) THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 15 10 18 71717 – GE332MAX-L/ULTRA (replaces 49708) UltraMax® Instant Start Multi-Voltage High-Efficiency 3 or 2 – F32T8 120 to 277 “L” .77 BF UltraMax® UL Class P cUL Listed 50 Hz/60 Hz Order information UL Listed See page 195 for warranty information. cUL Listed Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Type CC UL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 13 10 17 Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Anti-striation control for better light quality, with no striations • Lamp frequency >70 kHz • UL 55C Ambient Temperature rating Wiring diagram LFL 1C – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue Electrical characteristics 10 Pack 71717 UL Class P Power Factor% (>=) 99 98 99 97 99 98 99 97 99 98 99 97 99 98 99 97 Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Low Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Supply Current Frequency Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 Ballast Efficacy Factor 1.06 1.08 1.49 1.51 1.08 1.10 1.57 1.57 1.17 1.19 1.69 1.71 FCC – CLASS A Non-Consumer General characteristics Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 FCC – CLASS A Non-Consumer Safety and performance System Ballast Factor 1.18 1.18 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 Pallet Pack 71718 (replaces 31055) DIY Pack IP Pack 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 41 in (1041 mm) 25 in (635 mm) 34 in (864 mm) Specifications by lamp and wattage Lamp # of Lamps Line Volts System Watts 3 120 73 3 277 72 2 120 53 F32T8 2 277 53 3 120 69 3 277 68 2 120 49 F32T8/WM 2 277 49 3 120 65 3 277 65 2 120 46 F28T8 2 277 46 3 120 63 3 127 63 2 120 63 F25T12 2 277 63 Other compatible lamps: FE15T8, F25T8, F17T8, F32T8/25W Safety and performance See page 195 for warranty information. Nom. Line Current 0.63 A 0.27 A 0.45 A 0.20 A 0.60 A 0.26 A 0.42 A 0.19 A 0.57 A 0.25 A 0.40 A 0.18 A 0.53 A 0.24 A 0.56 A 0.25 A UL Type 1 Outdoor UL Type CC System Ballast Factor 0.77 0.77 0.77 0.77 0.77 0.77 0.77 0.77 0.77 0.77 0.77 0.77 UL Type HL Ballast Efficacy Factor 1.05 1.06 1.45 1.45 1.11 1.13 1.57 1.57 1.18 1.18 1.67 1.67 FCC – CLASS A Non-Consumer Power Factor% (>=) 99 98 99 97 99 98 99 97 99 98 99 96 99 97 99 97 UL Class P Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 cUL Listed UL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 13 18 10 RoHS Compliant Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 41 HID Electromagnetic Ballasts UL Type 1 Outdoor System Ballast Factor 1.00 1.00 0.96 0.96 1.00 1.00 0.97 0.97 1.00 1.00 0.98 0.97 0.97 0.97 0.95 0.95 # of Lamps Line Volts System Watts Nom. Line Current 3 120 111 0.92 A 3 277 109 0.40 A 2 120 77 0.68 A F32T8 2 277 76 0.30 A 3 120 106 0.89 A 3 277 104 0.39 A 2 120 73 0.65 A F32T8/WM 2 277 73 0.28 A 3 120 98 0.86 A 3 277 96 0.37 A 2 120 68 0.59 A F28T8 2 277 67 0.26 A 3 120 98 0.86 A 3 277 96 0.37 A 2 120 68 0.60 A F25T12 2 277 68 0.26 A Other compatible lamps: FE15T8, F40T8, F25T8, F17T8, F32T8/25W HID Electronic Ballasts # of Lamps Line Volts System Watts Nom. Line Current 2 120 63 0.53 A 2 277 62 0.23 A 1 277 35 0.13 A F32T8 1 120 34 0.29 A 2 120 60 0.50 A 2 277 60 0.22 A 1 277 33 0.13 A F32T8/WM 1 120 33 0.28 A 2 120 58 0.48 A 2 277 57 0.21 A 1 120 32 0.26 A F28T8 1 277 32 0.12 A 2 120 56 0.47 A 2 277 56 0.21 A 1 120 31 0.26 A F25T12 1 277 31 0.12 A Other compatible lamps: FE15T8, F25T8, F17T8, F40T8, F32T8/25W Safety and performance DIY Pack Lamp Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp 40 Pallet Pack 71715 (replaces 47549) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 34 in (864 mm) 41 in (1041 mm) 25 in (635 mm) 25 in (635 mm) Compact Fluorescent Ballasts Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) High Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Electrical characteristics 10 Pack 71421 50 Hz/60 Hz 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) Sign Ballasts 2 or 1 – F32T8 120 to 277 “N+” 1.0 BF UltraMax Power Factor% (>=) 99 96 99 94 99 96 99 94 99 96 99 93 99 97 99 93 FCC – CLASS A Non-Consumer UltraMax® Instant Start Multi-Voltage High-Efficiency Supply Current Frequency Wiring diagram – LFL 1C – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black Specifications by lamp and wattage Nom. Line Current 0.47 A 0.21 A 0.26 A 0.12 A 0.45 A 0.20 A 0.25 A 0.12 A 0.42 A 0.19 A 0.24 A 0.11 A 0.41 A 0.18 A 0.24 A 0.11 A 71421 – GE232MAX-N+ Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) High Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Supply Current Frequency • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Anti-striation control for better light quality, with no striations • Lamp frequency >70 kHz • UL 55C Ambient Temperature rating T12 Fluorescent Ballasts # of Lamps Line Volts System Watts 2 120 54 2 277 53 1 120 31 F32T8 1 277 31 2 120 53 2 277 52 1 120 29 F32T8/WM 1 277 29 2 120 49 2 277 48 1 120 27 F28T8 1 277 27 2 120 48 2 277 48 1 120 27 F25T12 1 277 27 Other compatible lamps: FE15T8, F25T8, F17T8, F32T8/25W 3 or 2 – F32T8 120 to 277 “H” 1.18 BF UltraMax® Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp UltraMax® Instant Start Multi-Voltage High-Efficiency General characteristics Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red White Black Blue Electrical characteristics Supply Current Frequency 71714 – GE332MAX-H/ULTRA (replaces 49776) T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Active Current Regulation regulates the output to each lamp with individual lamp inverter modules • Anti-striation control for better light quality, with no striations • Lamp frequency >70kHz T8 Fluorescent Ballasts UltraMax® Instant Start Multi-Voltage High-Efficiency UltraMax® Instant Start Multi-Voltage High-Efficiency T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps Quick Reference Guides gelighting.com UltraMax® Instant Start Multi-Voltage High-Efficiency T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps 71719 – GE332MAX-N/ULTRA (replaces 49773) ® 3 or 2 – F32T8 120 to 277 “N” .87 BF UltraMax General characteristics Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected 50 Hz/60 Hz Order information Pallet Pack 71721 (replaces 31053) DIY Pack 71722 (replaces 23941) IP Pack 9.5 in (241.30 mm) 1.7 in (43.18mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 25 in (635 mm) 41 in (1041 mm) 34 in (864 mm) Safety and performance UL Type HL System Ballast Factor 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 Ballast Efficacy Factor 1.06 1.08 1.50 1.50 1.11 1.12 1.58 1.58 1.20 1.22 1.70 1.70 FCC – CLASS A Non-Consumer Electrical characteristics ® UltraMax Instant Start Multi-Voltage High-Efficiency 3 or 2 – F32T8 120 to 277 “N+” 1.0 BF UltraMax ® General characteristics Order information 10 Pack 71723 UL Class P Power Factor% (>=) 99 98 99 97 99 98 99 97 99 98 99 97 99 98 99 97 cUL Listed Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Type CC UL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 13 10 16 Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 Order information DIY Pack IP Pack Wiring diagram LFL 1C – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue White and Black Red Blue RoHS Compliant UL Type 1 Outdoor UL Type HL System Ballast Factor 1.18 1.18 1.15 1.15 1.15 1.15 1.15 1.15 Ballast Efficacy Factor 0.80 0.81 1.00 1.01 0.79 0.81 1.04 1.05 1.15 1.15 1.15 1.15 0.86 0.87 1.13 1.15 FCC – CLASS A Non-Consumer 71725 – GE432MAX-L/ULTRA (replaces 49709) UltraMax® Instant Start Multi-Voltage High-Efficiency 4 or 3 – F32T8 120 to 277 “L” .77 BF UltraMax® General characteristics 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 34 in (864 mm) 25 in (635 mm) 41 in (1041 mm) 34 in (864 mm) cUL Listed Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Type CC UL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 14 10 17 10 10 10 10 Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 RoHS Compliant • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Anti-striation control for better light quality, with no striations • Lamp frequency >70 kHz • UL 55C Ambient Temperature rating Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Low Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Wiring diagram LFL 1D – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red Black White Yellow Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 71725 UL Class P Power Factor% (>=) 99 98 99 97 99 97 99 97 99 97 99 97 99 98 99 97 Pallet Pack 71726 (replaces 47547) DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 34 in (864 mm) 25 in (635 mm) 25 in (635 mm) 41 in (1041 mm) Specifications by lamp and wattage Nom. Line Current 0.77 A 0.33 A 0.54 A 0.24 A 0.73 A 0.32 A 0.52 A 0.23 A 0.69 A 0.30 A 0.50 A 0.22 A 0.67 A 0.29 A 0.48 A 0.22 A UL Type 1 Outdoor System Ballast Factor 1.00 1.00 0.94 0.94 1.00 1.00 0.95 0.95 1.00 1.00 0.96 0.95 0.93 0.93 0.93 0.93 UL Type CC Ballast Efficacy Factor 1.09 1.11 1.47 1.48 1.15 1.17 1.55 1.56 1.21 1.23 1.62 1.62 1.16 1.18 1.63 1.65 UL Type HL Power Factor% (>=) 99 98 99 97 99 98 99 97 99 98 99 97 99 98 99 97 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Class P cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 16 10 19 Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed See page 195 for warranty information. Lamp # of Lamps Line Volts System Watts 4 120 97 4 277 96 3 120 78 F32T8 3 277 77 4 120 92 4 277 91 3 120 72 F32T8/WM 3 277 72 4 120 87 4 277 86 3 120 67 F28T8 3 277 67 4 120 84 4 277 83 3 120 65 F25T12 3 277 65 Other compatible lamps: FE15T8, F25T8, F17T8, F32T8/25W Safety and performance See page 195 for warranty information. Nom. Line Current 0.84 A 0.37 A 0.65 A 0.29 A 0.80 A 0.36 A 0.61 A 0.27 A 0.77 A 0.34 A 0.59 A 0.26 A 0.71 A 0.31 A 0.58 A 0.25 A UL Type 1 Outdoor UL Type CC System Ballast Factor 0.77 0.77 0.77 0.77 0.77 0.77 0.77 0.77 0.77 0.77 0.77 0.77 UL Type HL Ballast Efficacy Factor 0.79 0.80 0.98 1.00 0.83 0.84 1.06 1.06 0.88 0.89 1.14 1.14 FCC – CLASS A Non-Consumer Power Factor% (>=) 99 98 99 97 99 98 99 97 99 98 99 97 99 97 99 97 RoHS Compliant Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Class P cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 15 10 18 Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed 43 HID Electromagnetic Ballasts Safety and performance 42 # of Lamps Line Volts System Watts Nom. Line Current 4 120 148 1.36 A 4 277 145 0.59 A 3 120 115 1.04 A F32T8 3 277 113 0.45 A 4 120 145 1.31 A 4 277 141 0.56 A 3 120 110 0.99 A F32T8/WM 3 277 109 0.43 A 4 120 134 1.21 A 4 277 132 0.52 A 3 120 102 0.92 A F25T12 3 277 101 0.40 A 4 120 133 1.20 A 4 277 131 0.52 A 3 120 101 0.91 A F28T8 3 277 100 0.40 A Other compatible lamps: FE15T8, F40T8, F25T8, F17T8, F32T8/25W HID Electronic Ballasts # of Lamps Line Volts System Watts 3 120 91 3 277 90 2 120 64 F32T8 2 277 64 3 120 87 3 277 86 2 120 61 F32T8/WM 2 277 61 3 120 83 3 277 82 2 120 59 F28T8 2 277 59 3 120 80 3 277 79 2 120 57 F25T12 2 277 57 Other compatible lamps: F25T8, F15T8, F40T8, F17T8, F32T8/25W IP Pack Lamp Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp DIY Pack 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 34 in (864 mm) 34 in (864 mm) 41 in (1041 mm) Compact Fluorescent Ballasts 50 Hz/60 Hz Pallet Pack Pallet Pack 71724 (replaces 47550) Safety and performance RoHS Compliant • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Active Current Regulation regulates the output to each lamp with individual lamp inverter modules • Anti-striation control for better light quality, with no striations Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 221°F (105°C) 70°C (158°F) Normal – High Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Electrical characteristics 10 Pack 71422 50 Hz/60 Hz 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) Sign Ballasts 71422 – GE332MAX-N+ Supply Current Frequency Wiring diagram – LFL 1D – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Red Blue Yellow Specifications by lamp and wattage Nom. Line Current 0.70 A 0.30 A 0.49 A 0.22 A 0.66 A 0.29 A 0.46 A 0.21 A 0.63 A 0.28 A 0.44 A 0.20 A 0.61 A 0.27 A 0.44 A 0.19 A UL Type 1 Outdoor Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) High Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Supply Current Frequency • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Anti-striation control for better light quality, with no striations • Lamp frequency >70 kHz • UL 55C Ambient Temperature rating T12 Fluorescent Ballasts # of Lamps Line Volts System Watts 3 120 82 3 277 80 2 120 58 F32T8 2 277 58 3 120 78 3 277 77 2 120 55 F32T8/WM 2 277 55 3 120 72 3 277 71 2 120 51 F28T8 2 277 51 3 120 72 3 277 71 2 120 49 F25T12 2 277 49 Other compatible lamps: FE15T8, F25T8, F17T8, F32T8/25W 4 or 3 – F32T8 120 to 277 “H” 1.18 BF UltraMax® Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp UltraMax® Instant Start Multi-Voltage High-Efficiency General characteristics Wiring diagram – LFL 1C – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black White Red Blue Electrical characteristics Supply Current Frequency 71723 – GE432MAX-H/ULTRA (replaces 49777) T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 10 Pack 71719 • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Anti-striation control for better light quality, with no striations • Lamp frequency >70 kHz • UL 55C Ambient Temperature rating T8 Fluorescent Ballasts UltraMax® Instant Start Multi-Voltage High-Efficiency UltraMax® Instant Start Multi-Voltage High-Efficiency T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps Quick Reference Guides gelighting.com UltraMax® Instant Start Multi-Voltage High-Efficiency T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps 71727 – GE432MAX-N/ULTRA (replaces 49774) ® 4 or 3 – F32T8 120 to 277 “N” .87 BF UltraMax General characteristics Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected 50 Hz/60 Hz Order information 10 Pack 71727 Pallet Pack 71729 (replaces 31054) DIY Pack 71730 (replaces 23942) IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 34 in (864 mm) 25 in (635 mm) 41 in (1041 mm) 25 in (635 mm) Safety and performance UL Type 1 Outdoor UL Type HL System Ballast Factor 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 Ballast Efficacy Factor 0.79 0.81 1.02 1.03 0.82 0.84 1.07 1.08 0.88 0.90 1.14 1.16 FCC – CLASS A Non-Consumer Electrical characteristics Supply Current Frequency 4 or 3 – F32T8 120 to 277 “N+” 1.0 BF UltraMax ® General characteristics Order information UL Class P Power Factor% (>=) 99 98 99 99 99 98 99 97 99 98 99 97 99 98 99 97 cUL Listed Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Type CC UL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 14 10 17 Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 DIY Pack IP Pack F96T8 F96T8/WM F40T8 F96T8/WMP # of Lamps 1 1 1 1 1 1 1 1 Line Volts 120 277 120 277 120 277 120 277 System Watts 54 53 51 51 38 38 Safety and performance Nom. Line Current 0.46 A 0.21 A 0.43 A 0.20 A 0.32 A 0.15 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.87 0.87 0.87 0.87 Ballast Efficacy Factor 1.61 1.64 1.70 1.70 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 95 99 95 99 95 99 95 cUL Listed Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Type CC UL Listed THD% (<=) 10 15 10 15 10 18 10 15 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant 49767 – GE259MAX-N/ULTRA UltraMax® Instant Start Multi-Voltage High-Efficiency 2 or 1 – F96T8 120 to 277 “N” .87 BF UltraMax® 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.16 lbs Side 18 ft 18 AWG Length (± 1 in) 41 in (1041 mm) 34 in (864 mm) 25 in (635 mm) 25 in (635 mm) Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Wiring diagram LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue White Red Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 49767 • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • Active Current Regulation regulates the output to each lamp with individual lamp inverter modules • Anti-striation control for better light quality, with no striations • UL Type CC Rating provides protection against arcing with F96T8 lamps only Pallet Pack DIY Pack 23954 IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 58 in (1473 mm) 25 in (635 mm) 66 in (1676 mm) UL Type HL Ballast Efficacy Factor 0.81 0.83 1.02 1.00 0.84 0.86 1.07 1.08 0.88 1.04 1.12 1.13 0.87 0.89 1.13 1.13 FCC – CLASS A Non-Consumer Power Factor% (>=) 99 98 97 99 99 98 99 97 99 97 99 96 99 97 99 96 UL Class P Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 cUL Listed UL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 16 10 19 Min. Starting Temp (°F/°C) -22/ -30 -22/ -30 -22/ -30 -22/ -30 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 Lamp # of Lamps Line Volts 2 120 2 277 1 120 F96T8 1 277 2 120 2 277 1 120 F96T8/WM 1 277 2 120 2 277 1 120 F96T8/WMP 1 277 2 120 2 277 1 120 F72T8 1 277 Other compatible lamps: F40T8 System Watts 107 105 62 62 102 100 59 59 85 84 59 59 79 78 44 44 RoHS Compliant Safety and performance See page 195 for warranty information. See page 195 for warranty information. Nom. Line Current 0.91 A 0.40 A 0.53 A 0.24 A 0.87 A 0.38 A 0.50 A 0.23 A 0.78 A 0.32 A 0.50 A 0.23 A 0.72 A 0.29 A 0.39 A 0.17 A UL Type 1 Outdoor UL Type CC System Ballast Factor 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.89 0.89 0.87 0.87 UL Type HL Ballast Efficacy Factor 0.81 0.82 1.40 1.40 0.85 0.87 1.47 1.47 1.04 1.05 1.47 1.47 FCC – CLASS A Non-Consumer Power Factor% (>=) 99 98 99 97 99 98 99 97 99 98 99 97 0.99 0.98 0.99 0.96 UL Class P Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 cUL Listed UL Listed THD% (<=) 10 15 10 20 10 15 10 20 10 15 10 20 10 13 10 20 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant 45 HID Electromagnetic Ballasts UL Type CC System Ballast Factor 1.00 1.00 1.15 0.97 1.00 1.00 0.99 0.99 1.00 1.00 0.99 0.99 0.96 0.96 0.97 0.97 HID Electronic Ballasts Specifications by lamp and wattage # of Lamps Line Volts System Watts Nom. Line Current 4 120 124 1.03 A 4 277 121 0.45 A 3 277 113 0.45 A F32T8 3 120 97 0.81 A 4 120 119 1.00 A 4 277 117 0.44 A 3 120 92 0.77 A F32T8/WM 3 277 92 0.35 A 4 120 114 0.95 A 4 277 96 0.36 A 3 120 89 0.74 A F28T8 3 277 88 0.33 A 4 120 110 0.92 A 4 277 108 0.40 A 3 120 86 0.72 A F25T12 3 277 86 0.32 A Other compatible lamps: FE15T8, F25T8, F40T8, F17T8, F32T8/25W UL Type 1 Outdoor Lamp Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp Safety and performance IP Pack Compact Fluorescent Ballasts Order information 44 DIY Pack General characteristics Wiring diagram LFL 1D – see example on page 72 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Yellow Blue and Red White and Black Black 50 Hz/60 Hz Pallet Pack Pallet Pack 8.8 in (225.80 mm) 1.1 in (27.94 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 66 in (1676 mm) 25 in (635 mm) 58 in (1473 mm) RoHS Compliant • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Active Current Regulation regulates the output to each lamp with individual lamp inverter modules • Anti-striation control for better light quality, with no striations Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 221°F (105°C) 70°C (158°F) Normal – High Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected Electrical characteristics 10 Pack 71423 50 Hz/60 Hz 9.5 in (241.30 mm) 1.7 in (43.18mm) 1.18 in (30.00 mm) Sign Ballasts UltraMax® Instant Start Multi-Voltage High-Efficiency Supply Current Frequency Wiring diagram – LFL 1A – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White Red Black Blue Specifications by lamp and wattage Nom. Line Current 0.94 A 0.40 A 0.72 A 0.32 A 0.90 A 0.39 A 0.68 A 0.30 A 0.84 A 0.37 A 0.67 A 0.29 A 0.76 A 0.33 A 0.64 A 0.28 A 71423 – GE432MAX-N+ Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Dimensions Electronic – High-Efficiency Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Anti-striation control, Auto-restart, Thermally protected 10 Pack 49766 • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Active Current Regulation regulates the output to each lamp with individual lamp inverter modules • Anti-striation control for better light quality, with no striations T12 Fluorescent Ballasts # of Lamps Line Volts System Watts 4 120 109 4 277 107 3 120 85 F32T8 3 277 84 4 120 105 4 277 103 3 120 81 F32T8/WM 3 277 80 4 120 98 4 277 96 3 120 76 F28T8 3 277 75 4 120 91 4 277 89 3 120 72 F25T8 3 277 71 Other compatible lamps: FE15T8, F25T12, F17T8, F32T8/25W 1 – F96T8 120 to 277 “N” .87 BF UltraMax® Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp UltraMax® Instant Start Multi-Voltage High-Efficiency General characteristics Wiring diagram – LFL 1D – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red White Yellow Black Electrical characteristics Supply Current Frequency 49766 – GE159MAX-N/ULTRA T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • Energy-saving high-efficiency instant-start electronic ballast (> 90%) • Multi-voltage technology handles voltage from 120 to 277V • UL Type CC Rating provides protection against arcing in electrical devices • Anti-striation control for better light quality, with no striations • Lamp frequency >70 kHz • UL 55C Ambient Temperature rating T8 Fluorescent Ballasts UltraMax® Instant Start Multi-Voltage High-Efficiency UltraMax® Instant Start Multi-Voltage High-Efficiency T8 Instant Start Ballasts For 46 – 59W 4 ft – 8 ft Slimline Lamps Quick Reference Guides gelighting.com ProLine® T8 Multivolt 120V – 277V T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps ProLine® T8 Multivolt 120V – 277V ® General characteristics Dimensions Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information 10 Pack 72269 Pallet Pack 72270 (replaces 30268) DIY Pack IP Pack Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 0.87 in (22.00 mm) 0.3 in (7.92 mm) 1.06 lbs Side 18 ft 18 AWG Length (± 1 in) 48 in (1219 mm) 22 in (559 mm) 30 in (762 mm) 22 in (559 mm) System Watts 29 28 29 29 27 27 25 25 19 18 Safety and performance Electrical characteristics 50 Hz/60 Hz Order information 10 Pack 72273 Pallet Pack 72274 (replaces 30308) UL Type 1 Outdoor UL Type HL System Ballast Factor 0.87 0.87 0.83 0.83 0.80 0.80 0.88 0.88 0.88 0.88 Ballast Efficacy Factor 3.00 3.11 2.88 2.87 3.01 3.01 3.54 3.52 4.68 4.78 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 95 99 95 99 94 99 94 91 99 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 10 10 15 20 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant ProLine® T8 Multivolt 120V – 277V 2 or 1 – F32T8 120 to 277 “H” 1.18 BF Multivolt ProLine ® General characteristics Dimensions Lamp # of Lamps Line Volts System Watts 2 120 49.5 2 277 48.6 1 120 35.0 F32T8 1 277 35.0 2 120 48.0 2 277 47.0 1 120 31.0 F32T8/WM 1 277 31.0 2 120 44.0 2 277 43.0 1 120 29.0 F28T8 1 277 29.0 2 120 40.0 2 277 40.0 1 120 27.0 F25T8 1 277 27.0 Other compatible lamps: F40T8, F17T8, F32T8/25W Order information Pallet Pack 30275 DIY Pack IP Pack FCC – CLASS A Non-Consumer 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 48 in (1219 mm) 22 in (559 mm) 30 in (762 mm) 22 in (559 mm) 2 or 1 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine® cUL Listed UL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 18 10 21 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant Dimensions Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red White Blue Black Electrical characteristics 50 Hz/60 Hz Order information 10 Pack 72275 UL Class P Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage ProLine® T8 Multivolt 120V – 277V Supply Current Frequency Power Factor% (>=) 99 96 99 94 99 96 99 94 99 96 99 94 99 95 99 93 Pallet Pack 72276 (replaces 30269) DIY Pack 72277 (replaces 97709) IP Pack 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 0.87 in (22.00 mm) 0.3 in (7.92 mm) 1.06 lbs Side 18 ft 18 AWG Length (± 1 in) 48 in (1219 mm) 22 in (559 mm) 30 in (762 mm) 22 in (559 mm) Specifications by lamp and wattage Nom. Line Current 0.65 A 0.28 A 0.44 A 0.20 A 0.63 A 0.28 A 0.42 A 0.19 A 0.57 A 0.26 A 0.39 A 0.18 A 0.51 A 0.23 A 0.35 A 0.16 A UL Type 1 Outdoor NRCan System Ballast Factor 1.18 1.18 1.34 1.34 1.13 1.13 1.30 1.30 1.10 1.10 1.28 1.28 1.16 1.16 1.32 1.32 UL Type HL Ballast Efficacy Factor 1.53 1.55 2.79 2.79 1.61 1.63 2.88 2.88 1.68 1.71 3.04 3.04 2.03 2.03 3.47 3.47 FCC – CLASS A Non-Consumer Power Factor% (>=) 99 98 99 97 99 98 99 96 99 98 99 96 99 97 99 96 UL Class P cUL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 7 15 10 18 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant See page 195 for warranty information. Lamp # of Lamps Line Volts System Watts 2 120 55 2 277 54 1 277 42 F32T8 1 120 41 2 120 55 2 277 54 1 120 40 F32T8/WM 1 277 40 2 120 49 2 277 48 1 277 36 F28T8 1 120 33 2 120 46 2 277 46 1 277 34 F25T8 1 120 33 Other compatible lamps: F17T8, F40T8, F32T8/25W Safety and performance See page 195 for warranty information. Nom. Line Current 0.52 A 0.23 A 0.16 A 0.36 A 0.48 A 0.21 A 0.33 A 0.15 A 0.44 A 0.19 A 0.14 A 0.29 A 0.41 A 0.18 A 0.13 A 0.29 A UL Type 1 Outdoor NRCan System Ballast Factor 0.87 0.87 1.02 1.02 0.82 0.82 0.97 0.97 0.80 0.80 0.94 0.94 0.85 0.85 1.03 1.03 UL Type HL Ballast Efficacy Factor 1.58 1.61 2.44 2.46 1.50 1.52 2.45 2.44 1.63 1.67 2.63 2.89 1.85 1.86 3.06 3.08 FCC – CLASS A Non-Consumer Power Factor% (>=) 99.0 96.8 95.6 99.0 99.0 96.5 95.0 95.5 99.0 96.2 95.4 99.0 99.0 96.0 94.7 99.0 UL Class P cUL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 16 19 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant 47 HID Electromagnetic Ballasts Safety and performance 46 UL Type HL Ballast Efficacy Factor 1.58 1.60 2.68 2.68 1.57 1.59 2.90 2.90 1.69 1.71 2.96 2.96 2.01 2.03 3.48 3.48 HID Electronic Ballasts # of Lamps Line Volts System Watts 2 120 77 2 277 76 1 120 48 F32T8 1 277 48 2 120 70 2 277 69 1 120 45 F32T8/WM 1 277 45 2 120 65 2 277 64 1 120 42 F28T8 1 277 42 2 120 57 2 277 57 1 120 38 F25T8 1 277 38 Other compatible lamps: F17T8, F40T8, F32T8/25W NRCan 72275 – GE-232-MV-N (replaces 30191) Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp UL Type 1 Outdoor System Ballast Factor 0.79 0.79 0.94 0.94 0.75 0.75 0.90 0.90 0.74 0.74 0.86 0.86 0.81 0.81 0.94 0.94 General characteristics Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red White Blue Black 50 Hz/60 Hz Nom. Line Current 0.50 A 0.22 A 0.32 A 0.14 A 0.43 A 0.19 A 0.29 A 0.13 A 0.41 A 0.17 A 0.28 A 0.13 A 0.36 A 0.16 A 0.25 A 0.12 A Compact Fluorescent Ballasts Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) High Active A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics 10 Pack 30198 IP Pack 8.8 in (225.80 mm) 0.87 in (22.00 mm) 0.3 in (7.92 mm) 1.06 lbs Side 18 ft 18 AWG Length (± 1 in) 48 in (1219 mm) 22 in (559 mm) 30 in (762 mm) 22 in (559 mm) Sign Ballasts • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 30198 – GE-232-MV-H Supply Current Frequency DIY Pack 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) Specifications by lamp and wattage Nom. Line Current 0.28 A 0.13 A 0.25 A 0.12 A 0.22 A 0.11 A 0.21 A 0.10 A 0.08 A 0.16 A Safety and performance Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red White Blue Black T12 Fluorescent Ballasts # of Lamps Line Volts 1 120 F32T8 1 277 1 120 F32T8/WM 1 277 1 120 F28T8 1 277 1 120 F25T8 1 277 1 277 F17T8 1 120 Other compatible lamps: F32T8/25W Dimensions Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Low Active A (20-24 decibels) Auto-restart, Thermally protected Supply Current Frequency Specifications by lamp and wattage Lamp 2 or 1 – F32T8 120 to 277 “L” .77 BF Multivolt ProLine® General characteristics Wiring diagram – LFL 1A – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red White Blue Black Electrical characteristics Supply Current Frequency ProLine® T8 Multivolt 120V – 277V T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 72273 – GE-232-MV-L (replaces 30247) T8 Fluorescent Ballasts • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 72269 – GE-132-MV-N (replaces 30189) 1 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine ProLine® T8 Multivolt 120V – 277V T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps Quick Reference Guides gelighting.com ProLine® T8 Multivolt 120V – 277V T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps ProLine® T8 Multivolt 120V – 277V ® General characteristics Dimensions Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) High Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information 10 Pack 30199 Pallet Pack 30296 DIY Pack IP Pack Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 48 in (1219 mm) 22 in (559 mm) 30 in (762 mm) 22 in (559 mm) Safety and performance Electrical characteristics UL Type 1 Outdoor UL Type HL System Ballast Factor 1.15 1.15 1.27 1.27 1.11 1.11 1.22 1.22 Ballast Efficacy Factor 1.01 1.04 1.47 1.49 1.07 1.09 1.54 1.56 1.07 1.07 1.20 1.20 1.13 1.16 1.66 1.66 FCC – CLASS A Non-Consumer Order information 10 Pack 30192 ® General characteristics cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 10 10 10 8 15 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 DIY Pack IP Pack UL Type HL Ballast Efficacy Factor 1.06 1.08 1.54 1.55 1.10 1.11 1.59 1.60 0.80 0.80 0.87 0.87 1.19 1.20 1.68 1.71 FCC – CLASS A Non-Consumer 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 48 in (1219 mm) 22 in (559 mm) 30 in (762 mm) 22 in (559 mm) 4 or 3 – F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine® UL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 13 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 RoHS Compliant Dimensions Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) High Active A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – LFL 1D – see example on page 72 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Red Yellow Blue Electrical characteristics 50 Hz/60 Hz Order information 10 Pack 30219 cUL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage ProLine® T8 Multivolt 120V – 277V Supply Current Frequency UL Class P Power Factor% (>=) 99.0 98.3 99.0 97.8 99.0 98.1 99.0 97.6 99.0 98.1 99.0 97.9 99.0 97.4 Pallet Pack 30303 DIY Pack IP Pack 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 22 in (559 mm) 36 in (914 mm) 38 in (965 mm) 30 in (762 mm) Specifications by lamp and wattage Nom. Line Current 0.70 A 0.31 A 0.55 A 0.24 A 0.62 A 0.27 A 0.50 A 0.22 A 0.63 A 0.27 A 0.57 A 0.25 A 0.46 A 0.20 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.78 0.80 0.87 0.87 0.74 0.74 0.83 0.83 Ballast Efficacy Factor 1.05 1.06 1.46 1.47 1.07 1.08 1.51 1.52 0.74 0.74 0.83 0.83 1.17 1.18 1.67 1.66 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 98 99 97 99 98 99 97 99 98 99 98 99 97 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 10 10 10 8 15 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 Lamp # of Lamps Line Volts System Watts 3 120 145 F40T8 3 277 141 4 120 144 4 277 140 3 120 122 F32T8 3 277 120 4 120 135 4 277 133 3 120 112 F32T8/WM 3 277 110 4 120 122 4 277 120 3 120 102 F28T8 3 277 101 Other compatible lamps: F25T8, F17T8, F32T8/25W Safety and performance RoHS Compliant See page 195 for warranty information. See page 195 for warranty information. Nom. Line Current 1.30 A 0.57 A 1.35 A 0.57 A 1.13 A 0.49 A 1.25 A 0.54 A 1.00 A 0.45 A 1.13 A 0.48 A 0.94 A 0.41 A UL Type 1 Outdoor UL Type HL System Ballast Factor Ballast Efficacy Factor 1.15 1.15 1.24 1.24 1.11 1.11 1.20 1.20 1.08 1.08 1.17 1.17 0.79 0.82 1.01 1.03 0.82 0.83 1.07 1.09 0.88 0.90 1.14 1.15 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 98 99 98 99 98 99 98 99 97 99 98 99 97 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 8 15 10 10 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 RoHS Compliant 49 HID Electromagnetic Ballasts 48 UL Type 1 Outdoor System Ballast Factor 0.87 0.87 0.96 0.96 0.83 0.83 0.92 0.92 HID Electronic Ballasts Safety and performance Nom. Line Current 0.73 A 0.32 A 0.56 A 0.26 A 0.68 A 0.30 A 0.52 A 0.23 A 0.67 A 0.29 A 0.60 A 0.26 A 0.46 A 0.29 A 30219 – GE-432-MV-H Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage # of Lamps Line Volts System Watts 3 120 74 3 277 73 2 120 60 F32T8 2 277 59 3 120 69 3 277 68 2 120 56 F32T8/WM 2 277 55 2 120 69 F40T8 2 277 68 3 120 63 3 277 63 2 120 50 F28T8 2 277 50 Other compatible lamps: F25T8, F17T8, F32T8/25W # of Lamps Line Volts System Watts 3 120 81 3 277 80 2 120 62 F32T8 2 277 62 3 120 75 3 277 74 2 120 58 F32T8/WM 2 277 57 2 120 75 F40T8 2 277 73 3 120 67 3 277 67 2 120 52 F28T8 2 277 51 Other compatible lamps: F25T8, F17T8, F32T8/25W Compact Fluorescent Ballasts Order information Lamp IP Pack General characteristics Wiring diagram – LFL 1C – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red White Blue Black 50 Hz/60 Hz Pallet Pack 30309 DIY Pack 97710 Lamp Safety and performance RoHS Compliant Dimensions Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Low Active A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics 10 Pack 30255 Pallet Pack 30270 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 48 in (1219 mm) 22 in (559 mm) 30 in (762 mm) 22 in (559 mm) Sign Ballasts 3 or 2 – F32T8 120 to 277 “L” .77 BF Multivolt ProLine UL Class P Power Factor% (>=) 99 98 99 97 99 98 99 97 99 98 99 98 99 97 • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage ProLine® T8 Multivolt 120V – 277V Supply Current Frequency 50 Hz/60 Hz 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) Specifications by lamp and wattage Nom. Line Current 0.95 A 0.41 A 0.79 A 0.34 A 0.91 A 0.39 A 0.73 A 0.32 A 0.95 A 0.41 A 0.84 A 0.36 A 0.67 A 0.30 A 30255 – GE-332-MV-L Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagram – LFL 1C – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red White Blue Black T12 Fluorescent Ballasts # of Lamps Line Volts System Watts 3 120 113 3 277 110 2 120 86 F32T8 2 277 85 3 120 103 3 277 101 2 120 79 F32T8/WM 2 277 78 2 120 102 F40T8 2 277 100 3 120 94 3 277 92 2 120 72 F28T8 2 277 72 Other compatible lamps: F25T8, F17T8, F32T8/25W Dimensions Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Supply Current Frequency Specifications by lamp and wattage Lamp 3 or 2 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine® General characteristics Wiring diagram – LFL 1C – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red White Blue Black Electrical characteristics Supply Current Frequency ProLine® T8 Multivolt 120V – 277V T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 30192 – GE-332-MV-N T8 Fluorescent Ballasts • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 30199 – GE-332-MV-H 3 or 2 – F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine ProLine® T8 Multivolt 120V – 277V T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps Quick Reference Guides gelighting.com ProLine® T8 Multivolt 120V – 277V T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps ProLine® T8 Multivolt 120V – 277V ® General characteristics Dimensions Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Low Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information 10 Pack 30262 Pallet Pack 30310 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in 43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 22 in (559 mm) 36 in (914 mm) 38 in (965 mm) 30 in (762 mm) Safety and performance UL Type 1 Outdoor UL Type HL System Ballast Factor Ballast Efficacy Factor 0.80 0.80 0.87 0.87 0.76 0.76 0.83 0.83 0.73 0.73 0.79 0.79 Electrical characteristics Supply Current Frequency FCC – CLASS A Non-Consumer Order information 10 Pack 30195 UL Class P cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 15 10 10 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 ® Dimensions 50 Hz/60 Hz Order information DIY Pack 97711 IP Pack F96T8/WM F96T8/WMP # of Lamps 1 1 1 1 1 1 Line Volts 120 277 120 277 120 277 System Watts 60 59 56 54 Safety and performance Nom. Line Current 0.55 A 0.22 A 0.51 A 0.22 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.89 0.89 0.85 0.85 Ballast Efficacy Factor 1.48 1.50 1.53 1.57 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 96 99 96 99 96 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 18 10 18 10 18 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 50 / 10 50 / 10 50 / 10 50 / 10 RoHS Compliant • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 30194 – GE-259-MV-N ProLine® T8 Multivolt 120V – 277V 2 or 1 – F96T8 120 to 277 “N” .87 BF Multivolt ProLine® Dimensions 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 22 in (559 mm) 36 in (914 mm) 38 in (965 mm) 30 in (762 mm) Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red White Black Blue Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 30194 Pallet Pack 30272 DIY Pack 97712 IP Pack 9.5 in (241.30 mm) 1.7 in (43.18mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 66 in (1676 mm) 25 in (635 mm) 25 in (635 mm) 58 in (1473 mm) Specifications by lamp and wattage Nom. Line Current 0.99 A 0.43 A 0.83 A 0.36 A 0.99 A 0.43 A 0.90 A 0.40 A 0.77 A 0.33 A 0.83 A 0.36 A 0.68 A 0.30 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.88 0.88 0.93 0.93 Ballast Efficacy Factor 0.78 0.79 0.99 1.01 0.83 0.83 0.91 0.91 0.80 0.80 0.85 0.85 0.80 0.80 1.04 1.05 0.85 0.87 1.10 1.10 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99.0 98.1 99.0 97.9 99.0 98.1 99.0 98.0 99.0 97.8 99.0 97.9 99.0 97.6 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 14 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 Lamp F96T8 F96T8/WM F96T8/WMP # of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 System Watts 113 110 72 72 104 101 67 66 Safety and performance Nom. Line Current 1.01 A 0.40 A 0.66 A 0.29 A 0.93 A 0.42 A 0.63 A 0.28 A UL Type 1 Outdoor UL Type HL System Ballast Factor Ballast Efficacy Factor FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99.0 98.0 99.0 97.0 99.0 98.4 99.0 97.0 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 16 10 13 10 17 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 50 / 10 50 / 10 50 / 10 50 / 10 RoHS Compliant RoHS Compliant See page 195 for warranty information. See page 195 for warranty information. 51 HID Electromagnetic Ballasts 50 F96T8 HID Electronic Ballasts Safety and performance Lamp Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage # of Lamps Line Volts System Watts 4 120 113 4 277 110 3 120 93 F32T8 3 277 92 3 120 112 F40T8 3 277 110 4 120 103 4 277 103 3 120 87 F32T8/WM 3 277 86 4 120 93 4 277 92 3 120 77 F28T8 3 277 77 Other compatible lamps: F25T8, F17T8, F32T8/25W IP Pack General characteristics Wiring diagram – LFL 1D – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Red Yellow Blue Electrical characteristics Lamp DIY Pack Compact Fluorescent Ballasts Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Pallet Pack 30271 Pallet Pack 30274 8.8 in (225.80 mm) 0.87 in (22.00 mm) 0.3 in (7.92 mm) 1.06 lbs Side 18 ft 18 AWG Length (± 1 in) 66 in (1676 mm) 25 in (635 mm) 25 in (635 mm) 58 in (1473 mm) RoHS Compliant • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage General characteristics 10 Pack 30193 50 Hz/60 Hz 9.5 in (241.30 mm) 1.3 in (33.00 mm) 1.18 in (30.00 mm) Sign Ballasts 4 or 3 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine Power Factor% (>=) 99 97 99 98 99 97 99 98 99 97 99 97 99 97 0.80 0.81 1.00 1.01 0.80 0.81 1.05 1.06 0.84 0.85 1.08 1.09 ProLine® T8 Multivolt 120V – 277V Supply Current Frequency Wiring diagram – LFL 1A – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red White Black Blue Specifications by lamp and wattage Nom. Line Current 0.94 A 0.41 A 0.95 A 0.41 A 0.80 A 0.35 A 0.84 A 0.36 A 0.73 A 0.32 A 0.77 A 0.33 A 0.67 A 0.29 A 30193 – GE-432-MV-N Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected T12 Fluorescent Ballasts # of Lamps Line Volts System Watts 3 120 102 F40T8 3 277 100 4 120 100 4 277 98 3 120 87 F32T8 3 277 86 4 120 95 4 277 93 3 120 79 F32T8/WM 3 277 78 4 120 86 4 277 85 3 120 73 F28T8 3 277 72 Other compatible lamps: F25T8, F17T8, F32T8/25W Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp 1 – F96T8 120 to 277 “N” .87 BF Multivolt ProLine® General characteristics Wiring diagram – LFL 1D – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Red Yellow Blue Electrical characteristics Supply Current Frequency ProLine® T8 Multivolt 120V – 277V T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 30195 – GE-159-MV-N T8 Fluorescent Ballasts • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 30262 – GE-432-MV-L 4 or 3 – F32T8 120 to 277 “L” .77 BF Multivolt ProLine ProLine® T8 Multivolt 120V – 277V T8 Instant Start Ballasts For 46 – 59W 4 ft – 8 ft Slimline Lamps Quick Reference Guides gelighting.com ProLine® T8 Multivolt High Output 120V – 277V T8 Instant Start Ballasts For 44 – 86W 4 ft – 8 ft HO Lamps ProLine® T8 Multivolt High Output 120V – 277V 2 or 1 – F96T8HO IS 120 to 277 “N” .87 BF General characteristics Dimensions Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information Pallet Pack 30187 DIY Pack IP Pack 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.04 lbs Side 18 ft 18 AWG Length (± 1 in) 58 in (1473 mm) 25 in (635 mm) 66 in (1676 mm) 25 in (635 mm) F96T8 F96T8/WM F96T8/WMP F72T8HO F60T8HO Electrical characteristics Supply Current Frequency F48T8HO Safety and performance 50 Hz/60 Hz Order information 10 Pack 23680 Pallet Pack 24161 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 24 in (610 mm) 32 in (813 mm) 24 in (610 mm) 32 in (813 mm) Specifications by lamp and wattage Nom. Line Current 1.30 A 0.56 A 0.82 A 0.36 A 1.29 A 0.52 A 0.79 A 0.33 A 1.23 A 0.51 A 0.77 A 0.33 A 1.11 A 0.47 A 0.69 A 0.30 A 1.02 A 0.43 A 0.64 A 0.28 A 0.87 A 0.37 A 0.55 A 0.25 A 0.84 A 0.35 A 0.24 A 0.53 A 0.72 A 0.30 A 0.20 A 0.45 A 0.70 A 0.30 A 0.45 A 0.20 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.80 0.82 0.82 0.82 1.17 1.17 Ballast Efficacy Factor 0.54 0.57 0.89 0.91 0.82 0.84 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 97 98 96 99 97 99 97 99 98 99 97 99 98 99 96 99 97 99 95 99 97 99 94 99 97 94 99 99 96 93 99 99 96 99 93 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 14 10 19 10 14 10 19 10 14 10 20 10 15 10 21 10 16 10 22 10 17 11 23 10 18 23 11 10 20 27 13 10 21 13 26 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant Lamp F32T8 F32T8/WM F25T12 F28T8 F25T8 F17T8 FE15T8 # of Lamps 1 1 1 1 1 1 1 Line Volts 120 120 120 120 120 120 120 System Watts 30 28 25 25 24 18 15 Safety and performance Nom. Line Current 0.26 A 0.24 A 0.22 A 0.22 A 0.21 A 0.16 A 0.13 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.87 0.86 0.87 0.84 0.87 0.91 0.91 Ballast Efficacy Factor 2.90 3.07 3.48 3.36 3.62 5.05 6.06 FCC – CLASS A Non-Consumer cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 60 / 16 0 / -18 60 / 16 0 / -18 0 / -18 0 / -18 RoHS Compliant • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Lightweight, low-profile housing • < 10% THD, > 99% power factor • Parallel lamp operation means system maintenance is easier to manage 23681 – GE-132-277-N ProLine® T8 Instant Start High Performance 1 – F32T8 277V “N” .87 BF ProLine® General characteristics Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Electronic – Standard Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – LFL 1A – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 23681 UL Class P Power Factor% (>=) 99 99 99 99 99 99 99 Pallet Pack 24162 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) Compact Fluorescent Ballasts F58T8 System Watts 146 143 92 90 142 139 87 86 136 134 86 86 125 123 78 77 115 114 73 72 98 97 62 62 95 92 62 60 78 78 50 49 78 77 51 51 Wiring diagram – LFL 1A – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue Sign Ballasts F40T8 Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 277 120 120 277 277 120 120 277 120 277 Electronic – Standard Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 24 in (610 mm) 32 in (813 mm) 24 in (610 mm) 32 in (813 mm) # of Lamps 1 1 1 1 1 1 1 Line Volts 277 277 277 277 277 277 277 System Watts 30 28 26 25 25 18 15 Safety and performance See page 195 for warranty information. See page 195 for warranty information. UL Type 1 Outdoor UL Type HL System Ballast Factor 0.87 0.86 0.84 0.87 0.87 0.91 0.91 Ballast Efficacy Factor 2.90 3.07 3.23 3.48 3.48 5.05 6.06 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 99 97 97 97 96 94 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 11 11 14 16 Min. Starting Temp (°F/°C) 0 / -18 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant 53 HID Electromagnetic Ballasts 52 Nom. Line Current 0.12 A 0.11 A 0.97 A 0.10 A 0.10 A 0.07 A 0.06 A HID Electronic Ballasts Specifications by lamp and wattage Lamp F32T8 F32T8/WM F28T8 F25T12 F25T8 F17T8 FE15T8 T12 Fluorescent Ballasts F96T8/HO # of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp 1 – F32T8 120V “N” .87 BF ProLine® General characteristics Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue White Red Black Electrical characteristics Supply Current Frequency ProLine® T8 Instant Start High Performance T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Lightweight, low-profile housing • < 10% THD, > 99% power factor • Parallel lamp operation means system maintenance is easier to manage 23680 – GE-132-120-N T8 Fluorescent Ballasts • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 30176 – GE-286-HO-MV-N 10 Pack 30176 ProLine® T8 Instant Start High Performance T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps Quick Reference Guides gelighting.com ProLine® T8 Instant Start High Performance T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps ProLine® T8 Instant Start High Performance ® General characteristics Dimensions Electronic – Standard Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information 10 Pack 23671 Pallet Pack 24163 DIY Pack IP Pack F32T8 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 24 in (610 mm) 32 in (813 mm) 24 in (610 mm) 32 in (813 mm) F28T8 F25T12 F25T8 F40T8 F17T8 FE15T8 Line Volts 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 System Watts 57 36 53 33 48 30 46 30 45 28 43 31 20 25 17 System Ballast Factor 0.87 0.94 0.86 0.94 0.84 0.91 0.87 0.94 0.87 0.97 Ballast Efficacy Factor 1.52 2.61 1.62 2.84 1.75 3.03 1.89 3.13 1.93 3.46 0.91 0.97 0.91 0.98 2.93 4.85 3.64 5.76 NRCan UL Type HL FCC – CLASS A Non-Consumer Order information 10 Pack 23673 Power Factor% (>=) 99 99 99 99 99 99 99 99 99 99 99 99 98 98 98 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 13 11 15 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 UL Class P cUL Listed UL Listed ® General characteristics Dimensions Electronic – Standard Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information Pallet Pack 24164 F32T8/WM F28T8 F25T12 F17T8 FE15T8 Safety and performance 54 F28T8 F25T12 F25T8 F17T8 Line Volts 120 120 120 120 120 120 120 120 120 120 120 120 120 120 System Watts 85 65 79 60 78 72 54 69 54 67 51 47 30 30 DIY Pack IP Pack System Watts 57 37 53 34 48 31 47 31 45 29 44 32 22 26 18 Nom. Line Current 0.73 A 0.56 A 0.68 A 0.51 A 0.67 A 0.62 A 0.47 A 0.60 A 0.46 A 0.58 A 0.44 A 0.41 A 0.31 A 0.26 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.87 0.94 0.86 0.94 Ballast Efficacy Factor 1.02 1.44 1.08 1.56 0.84 0.91 0.87 0.94 0.87 0.97 0.91 0.97 0.98 1.16 1.68 1.26 1.74 1.29 1.90 1.93 3.23 3.26 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 99 99 99 99 99 99 99 99 99 99 99 99 98 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 12 13 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 0 / -18 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Lightweight, low-profile housing • < 10% THD, > 99% power factor • Parallel lamp operation means system maintenance is easier to manage 23674 – GE-332-277-N ProLine® T8 Instant Start High Performance 3 or 2 – F32T8 277V “N” .87 BF ProLine® Dimensions 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 24 in (610 mm) 32 in (813 mm) 24 in (610 mm) 32 in (813 mm) Electronic – Standard Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – LFL 1C – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 23674 Pallet Pack 24166 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 24 in (610 mm) 32 in (813 mm) 24 in (610 mm) 32 in (813 mm) Specifications by lamp and wattage Nom. Line Current 0.22 A 0.14 A 0.20 A 0.13 A 0.18 A 0.12 A 0.18 A 0.12 A 0.17 A 0.11 A 0.16 A 0.12 A 0.08 A 0.10 A 0.07 A UL Type 1 Outdoor NRCan System Ballast Factor 0.87 0.94 0.86 0.94 0.84 0.91 0.87 0.94 0.87 0.97 Ballast Efficacy Factor 1.52 2.54 1.62 2.76 1.75 2.93 1.85 3.03 1.93 3.34 0.91 0.97 0.91 0.98 2.84 4.40 3.50 5.44 UL Type HL FCC – CLASS A Non-Consumer Power Factor% (>=) 99 99 99 99 99 97 98 97 98 97 99 98 96 97 95 UL Class P cUL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Listed THD% (<=) 10 10 10 10 10 10 10 13 10 13 10 12 16 14 17 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant See page 195 for warranty information. Lamp F32T8 F32T8/WM F40T8 F28T8 F25T12 F25T8 F17T8 FE15T8 # of Lamps 3 2 3 2 2 3 2 3 2 3 2 3 2 3 2 Line Volts 277 277 277 277 277 277 277 277 277 277 277 277 277 277 277 System Watts 84 64 78 59 77 70 53 68 53 65 50 46 36 36 28 Safety and performance See page 195 for warranty information. Nom. Line Current 0.31 A 0.24 A 0.29 A 0.22 A 0.29 A 0.26 A 0.20 A 0.25 A 0.20 A 0.24 A 0.19 A 0.17 A 0.13 A 0.14 A 0.11 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.87 0.94 0.86 0.94 Ballast Efficacy Factor 1.03 1.46 1.10 1.59 0.84 0.91 0.87 0.94 0.87 0.97 0.91 0.97 0.91 0.98 1.20 1.71 1.27 1.77 1.33 1.94 1.97 2.69 2.52 3.50 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 99 99 99 99 99 98 99 98 99 98 98 97 98 97 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 10 10 10 11 10 12 12 15 15 16 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 0 / -18 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant 55 HID Electromagnetic Ballasts F25T8 F40T8 F32T8/WM F40T8 # of Lamps 3 2 3 2 2 3 2 3 2 3 2 3 2 2 HID Electronic Ballasts F32T8 F32T8 Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Line Volts 277 277 277 277 277 277 277 277 277 277 277 277 277 277 277 Lamp General characteristics Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue Electrical characteristics Supply Current Frequency IP Pack Compact Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info DIY Pack Sign Ballasts ProLine® T8 Instant Start High Performance # of Lamps 2 1 2 1 2 1 2 1 2 1 1 2 1 2 1 Pallet Pack 24165 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 24 in (610 mm) 32 in (813 mm) 24 in (610 mm) 32 in (813 mm) RoHS Compliant • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Lightweight, low-profile housing • < 10% THD, > 99% power factor • Parallel lamp operation means system maintenance is easier to manage 23672 – GE-232-277-N Lamp 50 Hz/60 Hz 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) Specifications by lamp and wattage Nom. Line Current 0.49 A 0.31 A 0.45 A 0.29 A 0.41 A 0.26 A 0.40 A 0.26 A 0.38 A 0.25 A 0.37 A 0.27 A 0.18 A 0.22 A 0.15 A UL Type 1 Outdoor 2 or 1 – F32T8 277V “N” .87 BF ProLine Wiring diagram – LFL 1C – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue Electrical characteristics Supply Current Frequency Safety and performance Safety and performance 10 Pack 23672 Electronic – Standard Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected T12 Fluorescent Ballasts F32T8/WM # of Lamps 2 1 2 1 2 1 2 1 2 1 1 2 1 2 1 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp 3 or 2 – F32T8 120V “N” .87 BF ProLine® General characteristics Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue Electrical characteristics Supply Current Frequency ProLine® T8 Instant Start High Performance T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Lightweight, low-profile housing • < 10% THD, > 99% power factor • Parallel lamp operation means system maintenance is easier to manage 23673 – GE-332-120-N T8 Fluorescent Ballasts • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Lightweight, low-profile housing • < 10% THD, > 99% power factor • Parallel lamp operation means system maintenance is easier to manage 23671 – GE-232-120-N 2 or 1 – F32T8 120V “N” .87 BF ProLine ProLine® T8 Instant Start High Performance T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps Quick Reference Guides gelighting.com ProLine® T8 Instant Start High Performance T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps ProLine® T8 Instant Start High Performance ® General characteristics Dimensions Electronic – Standard Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information 10 Pack 23675 Pallet Pack 24167 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 24 in (610 mm) 45 in (1143 mm) 32 in (813 mm) 32 in (813 mm) F32T8/WM F28T8 F25T12 F25T8 F17T8 FE15T8 Line Volts 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 System Watts 113 93 113 105 86 96 77 91 75 87 72 60 50 48 40 Safety and performance UL Type HL System Ballast Factor 0.87 0.94 Ballast Efficacy Factor 0.76 1.01 Power Factor% (>=) 0.87 0.94 0.86 0.94 0.84 0.91 0.87 0.94 0.87 0.97 0.91 0.97 0.91 0.98 0.81 1.09 0.87 1.18 0.95 1.25 1.00 1.34 1.51 1.94 1.89 2.45 0.86 0.94 0.84 0.91 0.87 0.94 0.87 0.97 0.91 0.97 0.91 0.98 FCC – CLASS A Non-Consumer Electrical characteristics Supply Current Frequency Order information ® General characteristics UL Class P cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 11 12 14 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 DIY Pack IP Pack F32T8/WM F28T8 F25T12 F17T8 FE15T8 Safety and performance 56 F96T8/WMP Line Volts 120 120 120 120 120 120 System Watts 112 71 104 65 Safety and performance Nom. Line Current 0.96 A 0.61 A 0.89 A 0.56 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.87 1.04 0.87 1.04 Ballast Efficacy Factor 0.77 1.46 0.83 1.60 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 99 99 99 99 99 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Lightweight, low-profile housing • < 10% THD, > 99% power factor • Parallel lamp operation means system maintenance is easier to manage 23678 – GE-259-277-N ProLine® T8 Instant Start High Performance 2 or 1 – F96T8 277V “N” .87 BF ProLine® Dimensions 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 24 in (610 mm) 45 in (1143 mm) 32 in (813 mm) 32 in (813 mm) Electronic – Standard Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 23678 Pallet Pack 24170 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 66 in (1676 mm) 25 in (635 mm) 58 in (1473 mm) Specifications by lamp and wattage Nom. Line Current 0.41 A 0.41 A 0.34 A 0.38 A 0.32 A 0.35 A 0.29 A 0.33 A 0.28 A 0.32 A 0.26 A 0.22 A 0.19 A 0.18 A 0.15 A UL Type 1 Outdoor UL Type HL System Ballast Factor Ballast Efficacy Factor 0.87 0.94 0.86 0.94 0.84 0.91 0.87 0.94 0.87 0.97 0.91 0.97 0.91 0.98 0.79 1.02 0.84 1.11 0.90 1.21 0.97 1.25 1.02 1.38 1.54 1.97 1.93 2.51 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 12 13 14 15 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 Lamp F96T8 F96T8/WM F96T8/WMP # of Lamps 2 1 2 1 1 2 Line Volts 277 277 277 277 277 277 System Watts 110 71 102 66 Safety and performance Nom. Line Current 0.41 A 0.27 A 0.38 A 0.25 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.87 1.04 0.87 1.04 Ballast Efficacy Factor 0.79 1.46 0.85 1.57 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 99 99 98 98 99 cUL Listed UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 THD% (<=) 10 13 10 13 13 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 RoHS Compliant RoHS Compliant See page 195 for warranty information. See page 195 for warranty information. 57 HID Electromagnetic Ballasts F25T8 System Watts 111 110 92 102 84 93 75 89 75 85 70 59 49 47 39 F96T8/WM # of Lamps 2 1 2 1 1 2 HID Electronic Ballasts F32T8 Line Volts 277 277 277 277 277 277 277 277 277 277 277 277 277 277 277 F96T8 Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage # of Lamps 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 Lamp Compact Fluorescent Ballasts Order information Lamp F40T8 IP Pack General characteristics Wiring diagram – LFL 1D – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Yellow Red Blue 50 Hz/60 Hz Pallet Pack 24168 DIY Pack 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.40 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 66 in (1676 mm) 25 in (635 mm) 58 in (1473 mm) RoHS Compliant Dimensions Electronic – Standard Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics 10 Pack 23676 Pallet Pack 24169 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) Sign Ballasts ProLine® T8 Instant Start High Performance Supply Current Frequency 50 Hz/60 Hz 10 Pack 23677 • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Lightweight, low-profile housing • < 10% THD, > 99% power factor • Parallel lamp operation means system maintenance is easier to manage 23676 – GE-432-277-N Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue Specifications by lamp and wattage Nom. Line Current 0.97 A 0.80 A 0.97 A 0.90 A 0.74 A 0.81 A 0.66 A 0.78 A 0.65 A 0.74 A 0.62 A 0.52 A 0.43 A 0.42 A 0.35 A UL Type 1 Outdoor 4 or 3 – F32T8 277V “N” .87 BF ProLine Electronic – Standard Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected T12 Fluorescent Ballasts F32T8 F40T8 # of Lamps 4 3 3 4 3 4 3 4 3 4 3 4 3 4 3 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp 2 or 1 – F96T8 120V Normal Light .87 BF ProLine® General characteristics Wiring diagram – LFL 1D – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Yellow Red Blue Electrical characteristics Supply Current Frequency ProLine® T8 Instant Start High Performance T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Lightweight, low-profile housing • < 10% THD, > 99% power factor • Parallel lamp operation means system maintenance is easier to manage 23677 – GE-259-120-N T8 Fluorescent Ballasts • High-performance electronic ballast for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Lightweight, low-profile housing • < 10% THD, > 99% power factor • Parallel lamp operation means system maintenance is easier to manage 23675 – GE-432-120-N 4 or 3 – F32T8 120V “N” .87 BF ProLine ProLine® T8 Instant Start High Performance T8 Instant Start Ballasts For 46 – 59W 4 ft – 8 ft Slimline Lamps Quick Reference Guides gelighting.com Residential Grade ProLine® T8 120V T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps Electromagnetic T8 Ballasts T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps 97782 – GE232-120-RES 87125 – GEM232T8RS120 Residential Grade ProLine® T8 120V Electromagnetic T8 Ballasts 2 or 1 – F32T8 120V “N” .87 BF Residential ProLine® 2 – F32T8, RS, 120V, Magnetic Ballast (M232SR120C) 60 Hz 50 Hz Order information Pallet Pack DIY Pack 70137 IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 36 in (914 mm) 31 in (787 mm) 25 in (635 mm) 38 in (965 mm) 25 in (635 mm) Safety and performance System Watts 53 32 51 32 46 29 43 28 31 20 Nom. Line Current 0.81 A 0.55 A 0.79 A 0.54 A 0.72 A 0.50 A 0.69 A 0.48 A 0.52 A 0.37 A RoHS Compliant UL Type 1 Outdoor System Ballast Factor 0.83 0.99 0.82 0.99 0.81 0.97 0.88 1.04 0.88 1.03 UL Type HL Ballast Efficacy Factor 1.56 3.09 1.60 3.09 1.76 3.34 2.04 3.71 2.83 5.15 ANSI – C62.41 UL Class P Power Factor% (>=) 5 48 5 48 5 48 5 48 49 45 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 FCC Part 18 Class B at 120 Volts THD% (<=) 145 170 146 170 152 177 155 178 172 195 A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics 60 Hz Order information 10 Pack 87125 Pallet Pack DIY Pack Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 # of Lamps 2 Line Volts 120 System Watts 32 Safety and performance Dimensions A (20-24 decibels) Thermally protected 60 Hz 50 Hz F32T8/WM F28T8 F25T8 Safety and performance 58 UL Listed IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 31 in (787 mm) 31 in (787 mm) 25 in (635 mm) 38 in (965 mm) Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 87130 Pallet Pack DIY Pack IP Pack 87130 Wiring diagram – LFL PS2 – see example on page 73 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red White and Black Yellow 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.60 lbs Side 10 ft 18 AWG Length (± 1 in) 26 in (660 mm) 20 in (508 mm) 36 in (914 mm) Specifications by lamp and wattage Nom. Line Current 1.62 A 1.38 A 1.50 A 1.29 A 1.42 A 1.23 A 1.31 A 1.13 A 0.98 A 0.84 A UL Type 1 Outdoor RoHS Compliant System Ballast Factor 0.83 0.88 0.81 0.88 0.79 0.87 0.87 0.94 0.86 0.93 UL Type HL Ballast Efficacy Factor 0.79 1.02 0.82 1.08 0.87 1.16 1.04 1.38 1.48 1.93 ANSI – C62.41 Power Factor% (>=) 5 5 5 5 5 5 5 5 48 44 FCC Part 18 Class B at 120 Volts Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 0.19 1.7 1.7 1.7 1.7 UL Class P cUL Listed THD% (<=) 147 157 150 159 155 165 158 167 175 185 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 Lamp F32T8 F25T8 F17T8 # of Lamps 2 2 2 Line Volts 277 277 277 System Watts 77 60 47 Safety and performance Nom. Line Current 0.28 A 0.22 A 0.18 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.98 1.00 1.09 UL Class P Ballast Efficacy Factor 1.27 1.66 2.31 Power Factor% (>=) 98 98 96 Crest Factor (<=) 1.7 1.7 1.7 THD% (<=) 20 20 25 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 50 / 10 UL Listed UL Listed See page 195 for warranty information. See page 195 for warranty information. 59 HID Electromagnetic Ballasts F17T8 Min. Starting Temp (°F/°C) 50 / 10 HID Electronic Ballasts F32T8 System Watts 105 86 98 81 90 75 83 68 58 48 THD% (<=) 18 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Line Volts 120 120 120 120 120 120 120 120 120 120 Crest Factor (<=) 1.7 • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) • Great for areas requiring no EMI/RFI noise General characteristics Wiring diagram – LFL 1D – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red Blue White and Black Yellow Order information # of Lamps 4 3 4 3 4 3 4 3 4 3 UL Class P Power Factor% (>=) 98 Compact Fluorescent Ballasts Electronic – Standard Instant Start Instant start Parallel 10% 104°F (40°C) 70°C (158°F) Normal Electrical characteristics Lamp CSA Ballast Efficacy Factor 2.93 2 – F32T8, RS, 277V, Magnetic Ballast (M232SR277C) General characteristics DIY Pack 70138 UL Type HL System Ballast Factor 0.94 Sign Ballasts Electromagnetic T8 Ballasts 4 or 3 – F32T8 120V “N” .87 BF Residential ProLine® Pallet Pack 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.60 lbs Side 10 ft 18 AWG Length (± 1 in) 26 in (660 mm) 20 in (508 mm) 36 in (914 mm) cUL Listed Residential Grade ProLine® T8 120V 10 Pack 97783 Nom. Line Current 0.60 A UL Type 1 Outdoor 87130 – GEM232T8RS277 Supply Current Frequency Supply Current Frequency (MIN) IP Pack 87125 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) Specifications by lamp and wattage Lamp F32T8 97783 – GE432-120-RES Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagram – LFL PS2 – see example on page 73 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red White and Black Yellow T12 Fluorescent Ballasts # of Lamps Line Volts 2 120 F32T8 1 120 2 120 F32T8/WM 1 120 2 120 F28T8 1 120 2 120 F25T8 1 120 2 120 F17T8 1 120 Other compatible lamps: F32T8/25W Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal Supply Current Frequency Specifications by lamp and wattage Lamp Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T5 Fluorescent Ballasts Wiring diagram – LFL 1B – see example on page 72 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Red Blue White and Black Yellow Black Electrical characteristics Supply Current Frequency Supply Current Frequency (MIN) 10 Pack 97782 General characteristics Dimensions Electronic – Standard Instant Start Instant start Parallel 10% 104°F (40°C) 70°C (158°F) Normal Active A (20-24 decibels) Thermally protected T8 Fluorescent Ballasts General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) • Great for areas requiring no EMI/RFI noise Quick Reference Guides gelighting.com UltraStart® T8 Programmed Start T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps UltraStart® T8 Programmed Start ® 2 – F32T8 120V Normal Light .87 BF <10% THD UltraStart General characteristics Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information Pallet Pack 29630 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 48 in (1219 mm) 25 in (635 mm) Safety and performance System Watts 57 35 54 33 49 30 45 28 32 20 RoHS Compliant Nom. Line Current 0.49 A 0.29 A 0.46 A 0.28 A 0.42 A 0.26 A 0.39 A 0.24 A 0.28 A 0.17 A UL Type 1 Outdoor System Ballast Factor 0.89 1.03 0.88 1.02 0.85 0.97 0.89 1.04 0.89 1.02 UL Type HL Ballast Efficacy Factor 1.56 2.94 1.62 3.09 1.73 3.23 1.97 3.71 2.78 5.10 NRCan Power Factor% (>=) 99 99 99 99 99 99 99 98 99 98 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 ANSI – C62.41 UL Class P THD% (<=) 10 10 10 10 10 10 10 10 10 10 cUL Listed Electronic – Programmed/ Rapid Start Programmed start Parallel 10% 104°F (40°C) 70°C (158°F) Normal Active A (20-24 decibels) Anti-striation control, Thermally protected, Universal voltage Electrical characteristics Supply Current Frequency Supply Current Frequency (MIN) 50 Hz/Supply Current Frequency (MIN)/ 50 Hz/ 60 (MIN) 50 Hz/60 Hz Order information 10 Pack 96714 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed Pallet Pack 96717 UltraStart® T8 Programmed Start ® 2 – F32T8 277V Normal Light .87 BF <10% THD UltraStart General characteristics Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Specifications by lamp and wattage # of Lamps Line Volts System Watts 2 120 59 2 277 58 1 120 37 F32T8 1 277 37 2 120 55 2 277 54 1 120 34 F32T8/WM 1 277 34 2 120 51 2 277 50 1 120 32 F28T8 1 277 32 Other compatible lamps: F17T8, F25T8, F32T8/25W Electrical characteristics Supply Current Frequency 50 Hz/ 60 Hz Order information 10 Pack 29622 Pallet Pack 29632 DIY Pack IP Pack RoHS Compliant FCC – CLASS A Non-Consumer 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 48 in (1219 mm) 25 in (635 mm) UltraStart® T8 Programmed Start 2 or 1 – F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® ANSI – C62.41 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 RoHS Compliant cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 UL Listed Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 104°F (40°C) 70°C (158°F) Low Active A (20-24 decibels) Anti-striation control, Thermally protected, Universal voltage Wiring diagram – LFL PS2 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue and Red White Yellow Electrical characteristics Supply Current Frequency (MIN) 50 Hz/60 Hz Order information 10 Pack 96720 UL Class P Power Factor% (>=) 99 96 98 93 99 96 98 93 99 95 98 92 • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Anti-striation control for better light quality, with no striations • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Multi-voltage technology handles voltage from 120 to 277V • Parallel lamp operation means system maintenance is easier to manage 96720 – GE232-MVPS-L Pallet Pack DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 25 in (635 mm) 48 in (1219 mm) Specifications by lamp and wattage Nom. Line Current 0.21 A 0.14 A 0.21 A 13.00 A 0.19 A 0.12 A 0.18 A 0.11 A 0.12 A 0.08 A UL Type 1 Outdoor System Ballast Factor 0.89 1.03 0.88 1.01 0.86 0.98 0.90 1.03 0.90 1.02 ANSI – C62.41 Ballast Efficacy Factor 1.56 2.86 1.62 2.97 1.75 3.16 1.95 3.67 2.81 4.85 UL Type HL Power Factor% (>=) 97 95 97 94 97 94 96 93 93 88 FCC – CLASS A Non-Consumer NRCan Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P THD% (<=) 10 10 10 10 10 10 10 13 10 15 cUL Listed Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed Lamp # of Lamps Line Volts 2 120 2 277 1 120 F32T8 1 277 2 120 2 277 1 120 F32T8/WM 1 277 2 120 2 277 1 120 F28T8 1 277 2 277 2 120 1 277 F25T8 1 120 Other compatible lamps: F17T8, F32T8/25W System Watts 47 47 30 30 44 44 28 28 41 41 26 26 38 37 25 24 Safety and performance 60 Ballast Efficacy Factor 1.50 1.53 2.83 2.83 1.60 1.62 3.00 3.00 1.68 1.72 3.12 3.12 See page 195 for warranty information. See page 195 for warranty information. Nom. Line Current 0.39 A 0.17 A 0.28 A 0.11 A 0.36 A 0.16 A 0.26 A 0.11 A 0.34 A 0.15 A 0.24 A 0.10 A 0.14 A 0.31 A 0.09 A 0.23 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.71 0.71 0.81 0.81 0.67 0.67 0.79 0.79 0.65 0.65 0.77 0.77 0.73 0.73 0.86 0.86 Ballast Efficacy Factor 1.51 1.51 2.70 2.70 1.52 1.52 2.82 2.82 1.58 1.58 2.96 2.96 1.92 1.97 3.44 3.58 FCC – CLASS A Non-Consumer ANSI – C62.41 Power Factor% (>=) 99 95 98 90 99 95 98 90 99 94 98 90 94 99 85 97 RoHS Compliant Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 16 10 16 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed 61 HID Electromagnetic Ballasts Safety and performance System Watts 57 36 54 34 49 31 46 28 32 21 UL Type HL System Ballast Factor 0.89 0.89 1.05 1.05 0.88 0.88 1.02 1.02 0.86 0.86 1.00 1.00 HID Electronic Ballasts # of Lamps Line Volts 2 277 F32T8 1 277 2 277 F32T8/WM 1 277 2 277 F28T8 1 277 2 277 F25T8 1 277 2 277 F17T8 1 277 Other compatible lamps: F32T8/25W UL Type 1 Outdoor Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp Nom. Line Current 0.48 A 0.21 A 0.30 A 0.14 A 0.45 A 0.20 A 0.28 A 0.13 A 0.42 A 0.18 A 0.26 A 0.12 A General characteristics Wiring diagram – LFL PS2 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue and Red Yellow White 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 25 in (635 mm) 48 km Compact Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) Sign Ballasts • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage DIY Pack Lamp Safety and performance 29622 – GE-232-277-PS-N Wiring diagram – LFL 4a – see example on page 73 Case dimensions – Ref Drawing A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue and Red White Yellow T12 Fluorescent Ballasts # of Lamps Line Volts 2 120 F32T8 1 120 2 120 F32T8/WM 1 120 2 120 F28T8 1 120 2 120 F25T8 1 120 2 120 F17T8 1 120 Other compatible lamps: F32T8/25W Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp 2 or 1 – F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® General characteristics Wiring diagram – LFL PS2 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue and Red Yellow White Electrical characteristics Supply Current Frequency UltraStart® T8 Programmed Start T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • < 10% THD, > 99% power factor • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Anti-striation control for better light quality, with no striations • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Multi-voltage technology handles voltage from 120 to 277V 96714 – GE232-MVPS-N T8 Fluorescent Ballasts • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage 29621 – GE-232-120-PS-N 10 Pack 29621 UltraStart® T8 Programmed Start T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps Quick Reference Guides gelighting.com UltraStart® T8 Programmed Start T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps UltraStart® T8 Programmed Start ® 2 – F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart General characteristics Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) High Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information Pallet Pack 29651 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 2.40 lbs Side 18 ft 18 AWG Length (± 1 in) 33 in (838 mm) 25 in (635 mm) 25 in (635 mm) 48 in (1219 mm) 33 in (838 mm) System Watts 75 74 47 46 69 69 43 43 63 62 39 38 59 59 37 37 Safety and performance Nom. Line Current 0.64 A 0.28 A 0.19 A 0.40 A 0.60 A 0.27 A 0.36 A 0.18 A 0.54 A 0.25 A 0.16 A 0.32 A 0.50 A 0.24 A 0.32 A 0.15 A UL Type HL System Ballast Factor 1.15 1.15 1.37 1.37 1.14 1.14 Ballast Efficacy Factor 1.53 1.55 2.91 2.97 1.65 1.65 1.34 1.10 1.11 1.29 3.11 1.74 1.79 3.30 1.14 1.14 1.34 1.34 1.93 1.93 3.62 3.62 RoHS Compliant FCC – CLASS A Non-Consumer 2 – F32T8 120V-277V Ultra Low Watt .60 BF <10% THD General characteristics ANSI – C62.41 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 16 10 21 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 Order information DIY Pack IP Pack RoHS Compliant UL Type 1 Outdoor System Ballast Factor 0.89 1.00 0.87 0.98 0.85 0.95 0.89 0.99 0.88 0.98 ANSI – C62.41 Ballast Efficacy Factor 1.05 1.56 1.08 1.63 1.18 1.75 1.34 1.94 1.95 2.80 UL Type HL NRCan Power Factor% (>=) 99.00 99.00 0.99 99.00 99.00 99.00 99.00 99.00 99.00 99.00 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 FCC – CLASS A Non-Consumer UL Class P THD% (<=) 10 10 10 10 10 10 10 10 10 10 cUL Listed Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage 29624 – GE-332-277-PS-N UltraStart® T8 Programmed Start 3 – F32T8 277V Normal Light .87 BF <10% THD UltraStart® Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 33 in (838 mm) 25 in (635 mm) 48 in (1219 mm) Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – LFL PS3 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Red/White Yellow Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 29624 Pallet Pack 29634 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) Specifications by lamp and wattage Nom. Line Current 0.39 A 0.19 A 0.12 A 0.24 A 0.15 A 0.24 A 0.22 A 0.20 A 0.12 A 0.15 A 0.12 A 0.20 A 0.31 A 0.15 A 0.10 A 0.10 A 0.20 A UL Type 1 Outdoor System Ballast Factor 0.60 0.60 0.70 0.70 0.59 0.59 Ballast Efficacy Factor 1.33 1.36 2.50 2.59 1.40 1.40 0.68 0.59 0.59 0.67 2.51 1.51 1.51 2.68 0.61 0.61 1.69 1.69 0.68 0.68 2.95 3.09 ANSI – C62.41 UL Type HL NRCan Power Factor% (>=) 98.0 90.0 83.0 98.0 99.0 87.0 0.9 81.0 99.0 86.0 79.0 98.0 98.0 87.0 79.0 79.0 98.0 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 FCC Part 18 Class B at 120 Volts UL Class P THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 15 16 10 cUL Listed Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 Lamp # of Lamps Line Volts 3 277 2 277 3 277 F32T8/WM 2 277 3 277 F28T8 2 277 3 277 F25T8 2 277 3 277 F17T8 2 277 Other compatible lamps: F32T8/25W F32T8 Safety and performance System Watts 85 65 80 61 72 55 67 51 47 36 RoHS Compliant Nom. Line Current 0.32 A 0.25 A 0.30 A 0.23 A 0.27 A 0.21 A 0.26 A 0.20 A 0.18 A 0.14 A UL Type 1 Outdoor System Ballast Factor 0.89 1.00 0.88 0.98 0.86 0.95 0.89 0.99 0.89 0.98 ANSI – C62.41 Ballast Efficacy Factor 1.04 1.53 1.10 1.60 1.19 1.72 1.32 1.94 1.89 2.72 UL Type HL Power Factor% (>=) 97 97 98 98 98 98 97 96 96 94 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P cUL Listed THD% (<=) 10 10 10 10 10 10 10 11 10 13 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed UL Listed See page 195 for warranty information. See page 195 for warranty information. 63 HID Electromagnetic Ballasts Safety and performance 62 System Watts 45 44 28 27 42 42 27 27 39 39 25 24 36 36 23 23 22 RoHS Compliant Nom. Line Current 0.71 A 0.56 A 0.69 A 0.52 A 0.62 A 0.47 A 0.57 A 0.43 A 0.39 A 0.31 A HID Electronic Ballasts # of Lamps Line Volts 2 120 2 277 1 277 F32T8 1 120 2 120 2 277 1 120 F32T8/WM 1 277 2 120 2 277 1 277 F28T8 1 120 2 120 2 277 1 277 1 277 F25T8 1 120 Other compatible lamps: F17T8, F32T8/25W Safety and performance System Watts 84 64 80 60 72 54 66 51 45 35 UL Listed Specifications by lamp and wattage Lamp # of Lamps Line Volts 3 120 F32T8 2 120 3 120 F32T8/WM 2 120 3 120 F28T8 2 120 3 120 F25T8 2 120 3 120 F17T8 2 120 Other compatible lamps: F32T8/25W Compact Fluorescent Ballasts 50 Hz/ 60 Hz IP Pack General characteristics Wiring diagram – LFL PS2 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red White and Black Yellow Electrical characteristics DIY Pack 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) Specifications by lamp and wattage Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) Ultra low Active A (20-24 decibels) Auto-restart, Thermally protected Pallet Pack 29665 Pallet Pack 29633 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) Sign Ballasts UltraStart® T8 Programmed Start Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 29623 • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage 29671 – GE-232-MVPS-XL 10 Pack 29671 Power Factor% (>=) 98 94 90 98 98 95 98 90 94 98 89 98 98 93 98 87 Wiring diagram – LFL PS3 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Red/White Yellow Electrical characteristics Supply Current Frequency Lamp UL Type 1 Outdoor Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected T12 Fluorescent Ballasts # of Lamps Line Volts 2 120 2 277 1 277 F32T8 1 120 2 120 2 277 1 120 F32T8/WM 1 277 2 120 2 277 1 277 F28T8 1 120 2 120 2 277 1 120 F25T8 1 277 Other compatible lamps: F17T8, F32T8/25W Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp 3 – F32T8 120V Normal Light .87 BF <10% THD UltraStart® General characteristics Wiring diagram – LFL PS2 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red Black White Yellow Blue Electrical characteristics Supply Current Frequency UltraStart® T8 Programmed Start T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage 29623 – GE-332-120-PS-N T8 Fluorescent Ballasts • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage 29675 – GE-232-MVPS-H 10 Pack 29675 UltraStart® T8 Programmed Start T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps Quick Reference Guides gelighting.com UltraStart® T8 Programmed Start T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps UltraStart® T8 Programmed Start ® 3 – F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart General characteristics Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) High Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information Pallet Pack 29656 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 2.40 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) System Watts 110 108 82 82 102 100 77 76 92 91 69 58 86 85 65 64 Safety and performance Electrical characteristics Supply Current Frequency (MIN) UL Type HL System Ballast Factor 1.15 1.15 1.28 Ballast Efficacy Factor 1.04 1.06 1.56 1.13 1.14 1.10 1.14 1.26 1.09 1.10 1.23 1.65 1.18 1.20 1.78 1.14 1.14 1.25 1.32 1.34 1.92 RoHS Compliant FCC – CLASS A Non-Consumer Order information 10 Pack 96721 ® 3 – F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart General characteristics ANSI – C62.41 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 14 10 16 cUL Listed Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 50 Hz/60 Hz Order information DIY Pack IP Pack RoHS Compliant UL Type 1 Outdoor UL Type HL System Ballast Factor 0.71 0.71 0.77 0.77 0.67 0.67 0.75 0.75 0.66 0.66 0.74 0.74 0.66 0.74 0.82 RoHS Compliant 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) Power Factor% (>=) 99 96 98 92 99 95 98 92 99 95 98 92 95 99 98 0.82 UL Class P Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 ANSI – C62.41 cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 15 10 10 15 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage UltraStart® T8 Programmed Start 3 – F32T8 120V-277V Ultra Low Watt .60 BF <10% THD Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) Ultra low Active A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – LFL PS3 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Red/White Yellow Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 29672 Ballast Efficacy Factor 1.02 1.04 1.48 1.48 1.06 1.08 1.56 1.56 1.13 1.13 1.64 1.64 1.13 1.37 2.00 FCC – CLASS A Non-Consumer 29672 – GE-332-MVPS-XL Pallet Pack 29666 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) Specifications by lamp and wattage Lamp Nom. Line Current 0.72 A 0.30 A 0.54 A 0.24 A 0.66 A 0.28 A 0.51 A 0.22 A 0.61 A 0.26 A 0.47 A 0.21 A UL Type 1 Outdoor System Ballast Factor 0.89 0.89 0.98 0.98 0.86 0.86 0.96 0.96 0.84 0.84 0.93 0.93 ANSI – C62.41 Ballast Efficacy Factor 1.03 1.05 1.48 1.50 1.07 1.08 1.57 1.57 1.15 1.16 1.63 1.63 UL Type HL Power Factor% (>=) 99 97 98 95 99 97 98 95 99 97 98 95 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 UL Listed # of Lamps Line Volts 3 120 3 277 2 277 F32T8 2 120 3 120 3 277 2 120 F32T8/WM 2 277 3 120 3 277 2 120 F28T8 2 277 3 120 3 277 2 120 F25T8 2 277 Other compatible lamps: F17T8, F32T8/25W System Watts 67 66 50 49 61 60 45 45 57 56 42 42 53 53 40 40 Safety and performance 64 Nom. Line Current 0.60 A 0.26 A 0.45 A 0.19 A 0.54 A 0.24 A 0.40 A 0.18 A 0.49 A 0.22 A 0.38 A 0.17 A 0.22 A 0.45 A 0.35 A 90.0 A See page 195 for warranty information. See page 195 for warranty information. Nom. Line Current 0.58 A 0.26 A 0.21 A 0.42 A 0.53 A 0.24 A 0.04 A 0.18 A 0.49 A 0.22 A 0.35 A 0.17 A 0.45 A 0.21 A 0.35 A 0.16 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.60 0.60 0.64 0.64 0.59 0.59 Ballast Efficacy Factor 0.89 0.90 1.28 1.30 0.96 0.98 0.64 0.58 0.58 1.42 1.01 1.03 0.63 0.60 0.60 0.64 0.64 1.50 1.13 1.13 1.60 1.60 RoHS Compliant FCC – CLASS A Non-Consumer Power Factor% (>=) 98 93 92 98 99 94 98 92 99 94 98 91 98 92 98 89 ANSI – C62.41 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 13 10 14 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed 65 HID Electromagnetic Ballasts Safety and performance System Watts 69 68 52 52 63 62 48 48 58 58 45 45 58 54 41 0.158 HID Electronic Ballasts # of Lamps Line Volts System Watts 3 120 86 3 277 84 2 120 66 F32T8 2 277 65 3 120 80 3 277 79 2 120 61 F32T8/WM 2 277 61 3 120 73 3 277 72 2 120 57 F28T8 2 277 57 Other compatible lamps: F17T8, F25T8, F32T8/25W # of Lamps Line Volts 3 120 3 277 2 120 F32T8 2 277 3 120 3 277 2 120 F32T8/WM 2 277 3 120 3 277 2 120 F28T8 2 277 3 277 3 120 2 120 F25T8 2 277 Other compatible lamps: F17T8, F32T8/25W Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp IP Pack General characteristics Wiring diagram – LFL PS3 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Red/White Yellow Electrical characteristics Pallet Pack 96718 DIY Pack 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) Compact Fluorescent Ballasts Electronic – Programmed / Rapid Start Programmed start Parallel 10% 104°F (40°C) 70°C (158°F) Normal Active A (20-24 decibels) Anti-striation control, TCLP compliant, Thermally protected, Universal voltage Lamp Safety and performance UL Listed Dimensions Supply Current Frequency (MIN) Pallet Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) Sign Ballasts UltraStart® T8 Programmed Start 10 Pack 96715 Power Factor% (>=) 98 96 98 94 99 96 98 95 99 96 94 98 98 96 98 93 • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Anti-striation control for better light quality, with no striations • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Parallel lamp operation means system maintenance is easier to manage • Starting time visually the same as instant start 96715 – GE332-MVPS-N Additional Info 50 Hz/60 Hz Wiring diagram – LFL PS3 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Red/White Yellow Specifications by lamp and wattage Nom. Line Current 0.95 A 0.41 A 0.70 A 0.32 A 0.88 A 0.39 A 0.64 A 0.30 A 0.79 A 0.35 A 0.27 A 0.58 A 0.74 A 0.33 A 0.56 A 0.26 A UL Type 1 Outdoor Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Electronic – Programmed / Rapid Start Programmed start Parallel 10% 104°F (40°C) 70°C (158°F) Low Active A (20-24 decibels) Anti-striation control, Thermally protected, Universal voltage T12 Fluorescent Ballasts # of Lamps Line Volts 3 120 3 277 2 120 F32T8 2 277 3 120 3 277 2 120 F32T8/WM 2 277 3 120 3 277 2 277 F28T8 2 120 3 120 3 277 2 120 F25T8 2 277 Other compatible lamps: F17T8, F32T8/25W Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp 3 – F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® General characteristics Wiring diagram – LFL PS3 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Red/White Yellow Electrical characteristics Supply Current Frequency UltraStart® T8 Programmed Start T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Anti-striation control for better light quality, with no striations. • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Multi-voltage technology handles voltage from 120 to 277V • Parallel lamp operation means system maintenance is easier to manage 96721 – GE332-MVPS-L T8 Fluorescent Ballasts • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage 29676 – GE-332-MVPS-H 10 Pack 29676 UltraStart® T8 Programmed Start T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps Quick Reference Guides gelighting.com UltraStart® T8 Programmed Start T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps UltraStart® T8 Programmed Start ® 4 – F32T8 120V Normal Light .87 BF <10% THD UltraStart General characteristics Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information Pallet Pack 29635 DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) Safety and performance System Watts 112 92 106 87 96 79 87 73 61 51 Electronic – Programmed / Rapid Start Rapid start Parallel 10% 104°F (40°C) 70°C (158°F) Normal Active A (20-24 decibels) Anti-striation control, Thermally protected, Universal voltage Electrical characteristics Supply Current Frequency (MIN) 50 Hz/ 60 Hz Order information 10 Pack 96716 Pallet Pack 96719 UL Type 1 Outdoor System Ballast Factor 0.89 0.96 0.87 0.94 0.84 0.91 0.88 0.95 0.89 0.96 UL Type HL Ballast Efficacy Factor 0.79 1.04 0.82 1.08 0.87 1.15 1.01 1.30 1.45 1.88 ANSI – C62.41 Power Factor% (>=) 99 99 99 99 99 99 99 99 99 99 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 50 / 10 0 / -18 UL Listed Lamp # of Lamps Line Volts System Watts 4 120 114 4 277 112 3 120 93 F32T8 3 277 92 4 120 105 4 277 103 3 120 86 F32T8/WM 3 277 85 4 120 96 4 277 95 3 120 79 F28T8 3 277 78 Other compatible lamps: F17T8, F25T8, F32T8/25W Safety and performance UltraStart® T8 Programmed Start ® 4 – F32T8 277V Normal Light .87 BF <10% THD UltraStart General characteristics Dimensions Order information Pallet Pack 29650 DIY Pack IP Pack RoHS Compliant Nom. Line Current 0.42 A 0.35 A 0.39 A 0.32 A 0.35 A 0.29 A 0.33 A 0.28 A 0.24 A 0.20 A UL Type 1 Outdoor System Ballast Factor 0.89 0.96 0.86 0.94 0.84 0.91 0.88 0.95 0.88 0.95 ANSI – C62.41 Ballast Efficacy Factor 0.79 1.03 0.83 1.10 0.90 1.18 1.00 1.31 1.41 1.86 UL Type HL FCC – CLASS A Non-Consumer 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) 4 – F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart® Power Factor% (>=) 99 98 98 98 98 98 97 98 97 96 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 11 Wiring diagram – LFL PS4 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Blue/White Red/White Yellow Yellow Electrical characteristics 50 Hz 50 Hz/60 Hz Order information Min. Starting Temp (°F/°C) 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed See page 195 for warranty information. UL Class P THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 UL Listed Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 104°F (40°C) 70°C (158°F) Low – PS Active A (20-24 decibels) Anti-striation control, Thermally protected, Universal voltage Supply Current Frequency Supply Current Frequency (MIN) 10 Pack 71832 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Anti-striation control for better light quality, with no striations • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Multi-voltage technology handles voltage from 120 to 277V • Parallel lamp operation means system maintenance is easier to manage UltraStart® T8 Programmed Start Pallet Pack DIY Pack IP Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) 48 in (1219 mm) Specifications by lamp and wattage Lamp # of Lamps Line Volts System Watts 4 120 90 4 277 88 3 120 72 F32T8 3 277 71 4 120 85 4 277 83 3 120 68 F32T8/WM 3 277 67 4 120 77 4 277 76 3 120 63 F28T8 3 277 63 Other compatible lamps: F17T8, F25T8, F32T8/25W Safety and performance 66 ANSI – C62.41 Power Factor% (>=) 99 97 98 95 99 97 98 95 99 97 98 95 RoHS Compliant See page 195 for warranty information. Nom. Line Current 0.39 A 0.32 A 0.68 A 0.78 A 0.71 A 0.30 A 0.58 A 0.26 A 0.64 A 0.28 A 0.53 A 0.23 A UL Type 1 Outdoor System Ballast Factor 0.71 0.71 0.58 0.58 0.69 0.69 0.57 0.57 0.68 0.68 0.55 0.55 ANSI – C62.41 Ballast Efficacy Factor 0.78 0.80 0.81 0.82 0.81 0.83 0.84 0.85 0.88 0.89 0.88 0.88 UL Type HL Power Factor% (>=) 1 1 1 1 1 1 1 1 1 1 1 1 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 UL Listed 67 HID Electromagnetic Ballasts Safety and performance System Watts 112 93 103 85 93 77 88 72 62 51 Ballast Efficacy Factor 0.78 0.79 1.03 1.04 0.81 0.83 1.09 1.10 0.86 0.87 1.16 1.17 HID Electronic Ballasts # of Lamps Line Volts 4 277 F32T8 3 277 4 277 F32T8/WM 3 277 4 277 F28T8 3 277 4 277 F25T8 3 277 4 277 F17T8 3 277 Other compatible lamps: F32T8/25W UL Type HL 71832 – GE432-MVPS-L Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp UL Type 1 Outdoor System Ballast Factor 0.89 0.89 0.96 0.96 0.86 0.86 0.94 0.94 0.83 0.83 0.92 0.92 General characteristics Wiring diagram – LFL PS4 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Blue/White Red/White Yellow 50 Hz/60 Hz RoHS Compliant Nom. Line Current 0.97 A 0.41 A 0.78 A 0.34 A 0.88 A 0.37 A 0.72 A 0.31 A 0.81 A 0.35 A 0.66 A 0.29 A Compact Fluorescent Ballasts Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics 10 Pack 29627 IP Pack 8.8 in (225.80 mm) 1.1 in (28.70 mm) 0.3 in (7.92 mm) 1.65 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) Sign Ballasts • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage 29627 – GE-432-277-PS-N Supply Current Frequency DIY Pack 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.18 in (30.00 mm) Specifications by lamp and wattage Nom. Line Current 0.95 A 0.79 A 0.92 A 0.75 A 0.83 A 0.68 A 0.75 A 0.63 A 0.53 A 0.44 A RoHS Compliant Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagram – LFL PS4 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Blue/White Red/White Yellow T12 Fluorescent Ballasts # of Lamps Line Volts 4 120 F32T8 3 120 4 120 F32T8/WM 3 120 4 120 F28T8 3 120 4 120 F25T8 3 120 4 120 F17T8 3 120 Other compatible lamps: F32T8/25W Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp 4 F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart® General characteristics Wiring diagram – LFL PS4 – see example on page 73 Case dimensions – Ref Drawing -A – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Blue/White Red/White Yellow Electrical characteristics Supply Current Frequency UltraStart® T8 Programmed Start T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Anti-striation control for better light quality, with no striations • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Multi-voltage technology handles voltage from 120 to 277V • Parallel lamp operation means system maintenance is easier to manage 96716 – GE432-MVPS-N T8 Fluorescent Ballasts • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage 29625 – GE-432-120-PS-N 10 Pack 29625 UltraStart® T8 Programmed Start T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps Quick Reference Guides gelighting.com UltraStart® T8 Programmed Start T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps UltraStart® T8 Programmed Start 4 – F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart® General characteristics Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70°C (158°F) High Active A (20-24 decibels) Auto-restart, Thermally protected 50 Hz/60 Hz Order information Pallet Pack 29657 DIY Pack IP Pack 11.75 in (298.45 mm) 2.4 in (60.96 mm) 1.6 in (41.91 mm) 11.1 in (282.97 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 3.10 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 33 in (838 mm) 48 in (1219 mm) RoHS Compliant Nom. Line Current 1.27 A 0.55 A 1.03 A 0.45 A 1.20 A 0.52 A 0.95 A 0.43 A 1.08 A 0.47 A 0.86 A 0.39 A 1.00 A 0.44 A 0.83 A 0.37 A 0.69 A 0.31 A 0.58 A 0.26 A ANSI – C62.41 System Ballast Factor 1.16 1.16 1.26 1.26 1.15 1.15 Ballast Efficacy Factor 0.78 0.80 1.05 1.05 0.82 0.84 1.24 1.12 1.12 1.10 0.89 0.91 1.21 1.15 1.15 1.23 1.23 1.15 1.15 1.23 1.23 1.19 0.98 1.00 1.26 1.28 1.41 1.43 1.83 1.83 UL Type 1 Outdoor UL Type HL Power Factor% (>=) 98 96 98 96 97 97 98 97 97 97 98 97 98 96 98 96 98 95 98 95 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P cUL Listed THD% (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 16 10 15 10 16 10 15 Wiring diagram – LFL 18b – see example on page 74 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red Gray and Violet White and Black Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 80353 Pallet Pack DIY Pack IP Pack 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.30 lbs Side 12 ft 18 AWG Length (± 1 in) 51 in (1295 mm) 33 in (838 mm) 25 in (635 mm) Specifications by lamp and wattage Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 60 / 16 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed Lamp F32T8 F25T8 # of Lamps 1 1 Line Volts 120 120 System Watts 32 26 Safety and performance Nom. Line Current 0.26 A 0.21 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.88 0.90 Ballast Efficacy Factor 2.75 3.46 FCC – CLASS A Non-Consumer UL Listed Crest Factor (<=) 1.6 1.6 THD% (<=) 10 10 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 CSA • Integrate dimming ballasts with daylight harvesting for significant energy savings • Greater control of workspace lighting, ability to create a mood, energy savings • Designed to ensure optimum lamp performance with lamp current crest factor below the 1.7 ANSI standard • Start lamps according to ANSI recommendations throughout the entire dimming range 80355 – B232SR120V5 T8 Dimming Ballasts 2 – F32T8 DIM 100 to 5% RS 120 General characteristics Dimensions Electronic – Dimming Rapid start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – LFL 19 – see example on page 74 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red Gray and Violet White and Black Yellow Electrical characteristics Supply Current Frequency 60 Hz Order information Pallet Pack DIY Pack IP Pack 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) Compact Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 10 Pack 80355 UL Class P Power Factor% (>=) 99 99 Sign Ballasts Safety and performance System Watts 147 144 120 120 139 136 114 112 125 123 103 101 117 115 97 96 81 80 67 67 Electronic – Dimming Rapid start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected T12 Fluorescent Ballasts # of Lamps Line Volts 4 120 4 277 3 120 F32T8 3 277 4 120 4 277 3 120 F32T8/WM 3 277 4 120 4 277 3 120 F28T8 3 277 4 120 4 277 3 120 F25T8 3 277 4 120 4 277 3 120 F17T8 3 277 Other compatible lamps: F32T8/25W Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp 1 – F32T8 DIM 100 to 5% RS 120 General characteristics Wiring diagram – LFL PS4 – see example on page 73 Case dimensions – Ref Drawing LG – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Blue/White Red/White Yellow Electrical characteristics Supply Current Frequency T8 Dimming Ballasts 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.30 lbs Side 12 ft 18 AWG Length (± 1 in) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm) 51 in (1295 mm) # of Lamps 2 Line Volts 120 System Watts 62 Safety and performance See page 195 for warranty information. See page 195 for warranty information. UL Type 1 Outdoor UL Type HL System Ballast Factor 0.88 Ballast Efficacy Factor 1.41 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 UL Listed Crest Factor (<=) 1.6 THD% (<=) 10 Min. Starting Temp (°F/°C) 50 / 10 CSA 69 HID Electromagnetic Ballasts 68 Nom. Line Current 0.52 A HID Electronic Ballasts Specifications by lamp and wattage Lamp F32T8 T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • Integrate dimming ballasts with daylight harvesting for significant energy savings • Greater control of workspace lighting, ability to create a mood, energy savings • Designed to ensure optimum lamp performance with lamp current crest factor below the 1.7 ANSI standard • Start lamps according to ANSI recommendations throughout the entire dimming range 80353 – B132R120V5 T8 Fluorescent Ballasts • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Extends lamp life in frequently switched applications (> 100,000 on/off cycles) • Starting time visually the same as instant start • Multi-voltage technology handles voltage from 120 to 277V (H and XL series) • Parallel lamp operation means system maintenance is easier to manage 29678 – GE-432-MVPS-H 10 Pack 29678 T8 Dimming T8 Dimming Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps Quick Reference Guides gelighting.com T8 Dimming T8 Dimming Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps T8 Dimming Ballasts 2 – F32T8 Switch 100/50% RS 277 General characteristics Dimensions Electronic – Dimming Rapid start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected 60 Hz Order information Pallet Pack DIY Pack IP Pack # of Lamps 2 2 Line Volts 277 277 System Watts 62 48 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.30 lbs Side 12 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 25 in (635 mm) UL Type 1 Outdoor System Ballast Factor 0.88 0.88 Canadian Energy Standards Ballast Efficacy Factor 1.41 1.83 UL Type HL FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.7 UL Class P UL Listed THD% (<=) 10 10 2 – F32T8 DIM 100 to 5% RS 277 General characteristics Order information 10 Pack 80357 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 60 Hz Order information Pallet Pack DIY Pack IP Pack Line Volts 277 Safety and performance Nom. Line Current 0.22 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.88 Ballast Efficacy Factor 1.41 FCC – CLASS A Non-Consumer UL Class P Line Volts 120 System Watts 92 Nom. Line Current 0.77 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.88 Ballast Efficacy Factor 0.95 FCC – CLASS A Non-Consumer 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.30 lbs Side 12 ft 18 AWG Length (± 1 in) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm) 51 in (1295 mm) Power Factor% (>=) UL Listed Crest Factor (<=) 1.6 THD% (<=) 10 T8 Dimming Ballasts 3 – F32T8 DIM 100 to 5% RS 277 60 Hz Order information Pallet Pack DIY Pack IP Pack 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.30 lbs Side 12 ft 18 AWG Length (± 1 in) 33 in (838 mm) 36 in (914 mm) 36 in (914 mm) 25 in (635 mm) 36 in (914 mm) Specifications by lamp and wattage Lamp F32T8 # of Lamps 3 Line Volts 277 System Watts 92 Safety and performance See page 195 for warranty information. Min. Starting Temp (°F/°C) 50 / 10 CSA Wiring diagram – LFL 20 – see example on page 74 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Gray and Violet Blue and Red Red/White White and Black Yellow Electrical characteristics CSA THD% (<=) 10 Dimensions Electronic – Dimming Rapid start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Supply Current Frequency Min. Starting Temp (°F/°C) 50 / 10 UL Listed Crest Factor (<=) 1.5 • Integrate dimming ballasts with daylight harvesting for significant energy savings • Greater control of workspace lighting, ability to create a mood, energy savings • Designed to ensure optimum lamp performance with lamp current crest factor below the 1.7 ANSI standard • Start lamps according to ANSI recommendations throughout the entire dimming range 80358 – B332SR277V5 10 Pack 80358 UL Class P Power Factor% (>=) 99 See page 195 for warranty information. Nom. Line Current 0.33 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.88 Ballast Efficacy Factor 0.95 FCC – CLASS A Non-Consumer UL Class P Power Factor% (>=) 99 UL Listed Crest Factor (<=) 1.5 THD% (<=) 10 Min. Starting Temp (°F/°C) 50 / 10 CSA 71 HID Electromagnetic Ballasts 70 System Watts 62 # of Lamps 3 HID Electronic Ballasts # of Lamps 2 Specifications by lamp and wattage Lamp F32T8 Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp F32T8 IP Pack General characteristics Wiring diagram – LFL 19 – see example on page 74 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red Gray and Violet White and Black Yellow Electrical characteristics Supply Current Frequency DIY Pack 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.30 lbs Side 12 ft 18 AWG Length (± 1 in) 33 in (838 mm) 36 in (914 mm) 36 in (914 mm) 25 in (635 mm) 36 in (914 mm) Compact Fluorescent Ballasts Electronic – Dimming Rapid start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Pallet Pack Safety and performance CSA Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 60 Hz 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) Sign Ballasts T8 Dimming Ballasts Wiring diagram – LFL 20 – see example on page 74 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Gray and Violet Blue and Red Red/White White and Black Yellow Electrical characteristics Supply Current Frequency • Integrate dimming ballasts with daylight harvesting for significant energy savings • Greater control of workspace lighting, ability to create a mood, energy savings • Designed to ensure optimum lamp performance with lamp current crest factor below the 1.7 ANSI standard • Start lamps according to ANSI recommendations throughout the entire dimming range 80356 – B232SR277V5 10 Pack 80356 Power Factor% (>=) 99 99 Electronic – Dimming Rapid start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected T12 Fluorescent Ballasts Safety and performance Nom. Line Current 0.23 A 0.18 A Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp F32T8 F25T8 3 – F32T8 DIM 100 to 5% RS 120 General characteristics Wiring diagram – LFL 16 – see example on page 74 Case dimensions – Ref Drawing ST – see page 75 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Black/White Electrical characteristics Supply Current Frequency T8 Dimming Ballasts T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • Integrate dimming ballasts with daylight harvesting for significant energy savings • Greater control of workspace lighting, ability to create a mood, energy savings • Designed to ensure optimum lamp performance with lamp current crest factor below the 1.7 ANSI standard • Start lamps according to ANSI recommendations throughout the entire dimming range 80357 – B332SR120V5 T8 Fluorescent Ballasts • Integrate dimming ballasts with daylight harvesting for significant energy savings • Greater control of workspace lighting, ability to create a mood, energy savings • Designed to ensure optimum lamp performance with lamp current crest factor below the 1.7 ANSI standard • Start lamps according to ANSI recommendations throughout the entire dimming range 80362 – B232SR277S50 10 Pack 80362 T8 Dimming T8 Dimming Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps Quick Reference Guides gelighting.com Wiring Diagrams T8 Fluorescent Ballasts Wiring Diagrams T8 Fluorescent Ballasts LFL 1B LFL 4a LFL PS2 LFL 1C LFL 1D LFL PS3 LFL PS4 T8 Fluorescent Ballasts LFL 1A T5 Fluorescent Ballasts T12 Fluorescent Ballasts Sign Ballasts Compact Fluorescent Ballasts HID Electronic Ballasts See page 195 for warranty information. See page 195 for warranty information. 73 HID Electromagnetic Ballasts 72 Quick Reference Guides gelighting.com Wiring Diagrams T8 Fluorescent Ballasts LFL 18b Case Dimensions T8 Fluorescent Ballasts LFL 19 -A T8 Fluorescent Ballasts T5 Fluorescent Ballasts ST T12 Fluorescent Ballasts LFL 16 LFL 20 Sign Ballasts LG Compact Fluorescent Ballasts HID Electronic Ballasts See page 195 for warranty information. See page 195 for warranty information. 75 HID Electromagnetic Ballasts 74 T5 High Efficiency – Programmed Start T5 Electronic Programmed Start For F14 (2 ft), F21 (3 ft), F28 (4 ft), F35 (5 ft) HE T5 Lamps* 99653 – GE228MVPSH-A 2 or 1 – F14-F28T5HE, 120 to 277 UltraStart® PRS High Light 1.15 BF A Can General characteristics Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Electronic – Programmed / Rapid Start Programmed start Parallel 10% 104°F (40°C) 90°C (194°F) High (1.15) Active A (20-24 decibels) Auto-restart, End-of-Life Protection (EOL), Thermally protected, Universal voltage, Anti-striation control Additional Info Electrical characteristics Supply Current Frequency UltraStart® T5 programmed start ballasts for T5 fluorescent lamps. The GE UltraStart® Watt-Miser® T5 Lamp and Ballast System Advantage • 18 watts lower than standard 4-lamp, 54 watt T5 systems with the same light output • Operates lamps in parallel (which means if one lamp fails, the other lamps remain on) – significantly reduces lamp maintenance costs • Fast starting programmed start ballast < 700 milliseconds compared to standard T5 at > 1.1 to 1.5 seconds Order information 10 Pack 99653 Pallet Pack 99654 DIY Pack # of Lamps Line Volts System Watts Nom. Line Current 2 120 72 0.60 A 2 277 70 0.25 A 1 120 45 0.37 A F28T5/HE 1 277 45 0.17 A 2 120 68 0.57 A F28T5/WM 2 277 67 0.25 A 2 120 57 0.47 A 2 277 56 0.21 A 1 120 36 0.30 A 1 277 36 0.14 A F21T5/HE 1 120 43 0.36 A F28T5WM 1 277 43 0.17 A Other compatible lamps: F28T5/WM, F14T5/HE, F14T5/WM, F21T5/WM, F28T5/HL UL Type CC RoHS Compliant High Efficiency (HE) Lamps (F14T5, F21T5, F28T5, F35T5 – standard, high-lumen and Watt-Miser®) These lamps are high efficiency (HE), delivering around 100 lumens per watt and, while operating at the same lamp arc current, can be operated on the same ballast if the ballast system power and starting voltage are appropriate for the lamp load. UL Type 1 Outdoor System Ballast Factor 1.16 1.16 1.36 1.36 UL Listed UL Type HL Power Factor % (>=) 99 97 99 93 99 96 99 95 99 90 99 92 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.65 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P cUL Listed THD (<=) 10 9 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 Meets ANSI Standard C62.41-1991 Meets ANSI Standard C82.11- cons 2002 99655 – GE228MVPS-A T5 High Efficiency - UltraStart® Programmed Start 2 or 1 – F14-F35T5HE, 120 – 277 UltraStart® PRS Normal Light - .95 BF A Can General characteristics • High Efficiency T5 ballast with Continuous Cathode Cutout Technology • Lower Maintenance Costs with Parallel Lamp Operation • Fast Starting Time <700ms • Multi-Voltage technology means a single ballast handles voltage from 108V to 305V • Auto-Restart withstands temporary losses in power without the need to cycle power • UltraCool™ Operation 90C case rating Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Electronic – Programmed / Rapid Start Programmed start Parallel 10% 104°F (40°C) 90°C (194°F) Normal Active A (20-24 decibels) Auto-restart, End-of-Life Protection (EOL), Thermally protected, Universal voltage, Anti-striation control Additional Info Electrical characteristics Supply Current Frequency 60 Hz Order information Pallet Pack 99656 DIY Pack Wiring diagram – LFL 4a – see example on page 82 Case dimensions – Ref Drawing -A Can – see page 83 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Green Yellow 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.2 in (30.48 mm) 8.9 in (226.06 mm) 0.3 in (6.35 mm) 1.49 lbs Side 8 ft 18 AWG Length (± 1 in) 25 in (635 mm) 34 in (864 mm) 3.5 in (89 mm) 45 in (1143 mm) IP Pack ® High Output (HO) Lamps (F24T5, F39T5, F54T5, F49T5, F80T5 – standard and Watt-Miser ) These lamps are driven for high light output and are slightly less efficient (LPW) than HE lamps. They have unique lamp arc currents and starting voltages by wattage that require a specific ballast for each HO lamp wattage. Specifications by lamp and wattage Lamp Safety and performance UL Type CC UL Type 1 Outdoor UL Listed Ballast Efficacy Factor UL Type HL 1.60 1.63 2.87 2.87 1.67 1.67 Power Factor % (>=) 99 97 99 93 99 96 99 91 99 95 99 90 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P cUL Listed THD (<=) 10 9 10 10 10 9 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 Meets ANSI Standard C62.41-1991 RoHS Compliant Meets ANSI Standard C82.11- cons 2002 76 See T8 ballast section (page 37) for nomenclature information. See page 195 for warranty information. *T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length. 77 HID Electromagnetic Ballasts # of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor 2 120 75 0.62 A 2 277 73 0.27 A 1 120 46 0.39 A F35T5/HE 1 277 46 0.18 A 2 120 60 0.50 A 0.96 2 277 59 0.23 A 0.96 1 120 38 0.31 A 1.09 F28T5/HE 1 277 38 0.15 A 1.09 2 120 57 0.48 A 0.95 2 277 57 0.21 A 0.95 1 120 36 0.30 A F28T5/WM 1 277 36 0.15 A Other compatible lamps: F21T5/HE, F21T5/WM, F14T5/HE, F14T5/WM, F35T5/WM, F28T5/HL HID Electronic Ballasts 10 Pack 99655 Ballast Efficacy Factor 1.61 1.66 3.02 3.02 Compact Fluorescent Ballasts GE T5 lamps can be electrically characterized into two groups: IP Pack Sign Ballasts T5 Lamps 8.9 in (226.06 mm) 0.3 in (6.35 mm) 1.49 lbs Side 8 ft 18 AWG Length (± 1 in) 25 in (635 mm) 34 in (864 mm) 3.5 in (89 mm) 45 in (1143 mm) Specifications by lamp and wattage Lamp Safety and performance GE UltraStart® T5 programmed start ballasts use a control circuit to apply very precise cathode heat to ensure lamp cathodes have reached optimum temperature during lamp starting. Precise starting reduces the amount of cathode degradation associated with each start and increases lamp life significantly. After starting the lamps, continuous cathode cutout technology (CCC) is applied—which eliminates wasted power to the lamps, resulting in high efficiencies. GE UltraStart® systems also have the advantage of operating lamps in parallel. Parallel (versus series) lamp operation ballasts typically reduce spot relamping costs by 50% or extend group relamping by 15% or more due to average lamp mortality early failures. 9.5 in (241.30 mm) 1.7 in (43.18 mm) 1.2 in (30.48 mm) T12 Fluorescent Ballasts GE has developed a line of T5 ballasts that incorporate the benefits of programmed start ballasts with the energy savings, fast starting and parallel lamp operation of instant start ballasts. GE’s UltraStart® T5 ballasts use low energy loss, high efficiency components along with continuous cathode cutout (CCC) technology—resulting in 8 fewer watts than standard 4-lamp 54 watt T5 ballasts. GE’s UltraStart® T5 ballasts offer a 44% improvement over standard T5 ballasts and create a new industry threshold for high efficiency ballasts. 60 Hz Wiring diagram – LFL 4a – see example on page 82 Case dimensions – Ref Drawing -A Can – see page 83 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Green Yellow T5 Fluorescent Ballasts Understanding T5 Electronic Programmed Start Ballasts T8 Fluorescent Ballasts T5 High Efficiency - UltraStart® Programmed Start • High Efficiency T5 ballast with Continuous Cathode Cutout Technology • Lower Maintenance Costs with Parallel Lamp Operation • Fast Starting Time <700ms • Multi-Voltage technology means a single ballast handles voltage from 108V to 305V • Auto-Restart withstands temporary losses in power without the need to cycle power • UltraCool™ Operation 90C case rating Quick Reference Guides gelighting.com T5 High Efficiency – Programmed Start T5 Electronic Programmed Start For F14 (2 ft), F21 (3 ft), F28 (4 ft), F35 (5 ft) HE T5 Lamps* T5 High Output - Programmed Start 2 – F24T5HO PRS UNV 50/60 Hz C Can 2 – F28T5 PRS UNV 50/60 Hz, C Can General characteristics General characteristics Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Wiring diagram – LFL 4b – see example on page 82 Case dimensions – Ref Drawing -C Can – see page 83 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge 14.25 in (361.95 mm) 1.2 in (29.97 mm) 1.0 in (25.40 mm) 13.75 in (349.25 mm) 0.25 in (6.35 mm) 1.00 lb Poke-in 18 ft 18 AWG F28T5/HE F21T5/HE F14T5/HE 13.8 in (349.25 mm) 0.25 in (6.35 mm) 1.0 lb Poke-in 18 ft 18 AWG 50 Hz/60 Hz DIY Pack 10 Pack 47534 IP Pack Line Volts 120 277 120 277 120 277 120 277 120 277 120 120 277 120 277 Safety and performance System Watts 81 78 40 40 66 64 33 33 49 48 25 34 34 18 18 Pallet Pack DIY Pack IP Pack Specifications by lamp and wattage Nom. Line Current 0.67 A 0.28 A 0.34 A 0.15 A 0.55 A 0.23 A 0.28 A 0.12 A 0.41 A 0.17 A 0.21 A 0.28 A 0.12 A 0.15 A 0.07 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.98 0.98 0.98 0.95 0.98 0.98 0.98 0.95 0.98 0.98 0.98 0.98 0.95 0.98 0.95 Ballast Efficacy Factor 1.20 1.25 2.45 2.37 1.48 1.53 2.96 2.87 2.00 2.04 3.92 2.88 2.79 5.44 5.27 FCC – CLASS A Non-Consumer UL Class P Power Factor % (>=) CSA Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 15 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed Lamp # of Lamps Line Volts 2 120 2 277 1 120 F24T5/HO 1 277 2 120 2 277 1 120 FT24W/4P 1 277 2 120 2 277 1 120 FT24W/2G10 1 277 1 120 F39T5/HO 1 277 1 120 FT36W/4P 1 277 Other compatible lamps: F36W/2G10 System Watts 53 52 28 28 52 51 27 27 48 47 24 24 41 40 36 36 Safety and performance Nom. Line Current 0.45 A 0.19 A 0.23 A 0.10 A 0.43 A 0.18 A 0.22 A 0.10 A 0.40 A 0.17 A 0.20 A 0.09 A 0.34 A 0.15 A 0.30 A 0.13 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.98 0.98 0.98 0.95 0.98 0.98 0.98 0.95 0.98 0.98 0.98 0.95 0.98 0.98 0.98 0.95 Ballast Efficacy Factor 1.84 1.88 3.50 3.39 1.88 1.92 3.62 3.51 2.04 2.08 4.08 3.95 2.39 2.45 2.72 2.63 FCC – CLASS A Non-Consumer UL Class P Power Factor % (>=) 95 95 95 95 CSA Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD (<=) 10 10 10 10 10 10 10 15 10 10 10 15 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed Sign Ballasts • Electronic ballasts for all general fluorescent applications • Extends lamp life in frequently switched applications • Reduced lamp replacement cost; ideal for use with occupancy sensors 47540 – B239PUNV-DOG1C T5 High Output - Programmed Start T12 Fluorescent Ballasts F35T5/HE # of Lamps 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 14.3 in (361.95 mm) 1.2 in (29.97 mm) 1.0 in (25.40 mm) Order information Pallet Pack Specifications by lamp and wattage Lamp Wiring diagram – LFL 4b – see example on page 82 Case dimensions – Ref Drawing -C Can – see page 83 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information 10 Pack 47536 Electronic – Programmed / Rapid Start Programmed start Series 10% 105°F (41°C) 75°C (167°F) Normal Active A (20-24 decibels) Auto-restart, End-of-Life Protection (EOL), Thermally protected, Universal voltage Additional Info Electrical characteristics Supply Current Frequency Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating T5 Fluorescent Ballasts Electronic – Programmed / Rapid Start Programmed start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, End-of-Life Protection (EOL), Thermally protected, Universal voltage Additional Info T8 Fluorescent Ballasts T5 High Efficiency - Programmed Start • Electronic ballasts for all general fluorescent applications • Extends lamp life in frequently switched applications • Reduced lamp replacement cost; ideal for use with occupancy sensors 47534 – B224PUNV-COG1C • Electronic ballasts for all general fluorescent applications • Extends lamp life in frequently switched applications • Reduced lamp replacement cost; ideal for use with occupancy sensors 47536 – B228PUNV-C0G1C T5 High Output – Programmed Start T5 Electronic Programmed Start For F24 (2 ft), F39 (3 ft), F54 (4 ft), F80 (5 ft) HO T5 Lamps* Quick Reference Guides gelighting.com 2 – F39T5HO PRS UNV 50/60 Hz D Can General characteristics Dimensions Electronic – Programmed / Rapid Start Programmed start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, End-of-Life Protection (EOL), Thermally protected, Universal voltage Additional Info Wiring diagrams – LFL 4b – see example on page 82 Case dimensions – Ref Drawing -D Can – see page 83 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge 16.9 in (428.75 mm) 1.2 in (29.97 mm) 1.0 in (25.40 mm) Compact Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating 16.2 in (411.48 mm) 0.25 in (6.35 mm) Poke-in 18 ft 18 AWG Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information Pallet Pack DIY Pack IP Pack Specifications by lamp and wattage Lamp F39T5/HO FT39W/4P Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 System Watts 89 88 47 47 71 70 38 38 59 59 32 32 Safety and performance 78 See page 195 for warranty information. See page 195 for warranty information. Nom. Line Current 0.74 A 0.32 A 0.39 A 0.17 A 0.59 A 0.25 A 0.31 A 0.14 A 0.51 A 0.22 A 0.26 A 0.12 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.98 0.98 0.98 0.95 0.98 0.95 0.98 0.90 0.98 0.95 0.98 0.90 Ballast Efficacy Factor 1.10 1.11 2.08 2.02 1.38 1.35 2.57 2.36 1.66 1.61 3.06 2.81 FCC – CLASS A Non-Consumer UL Class P Power Factor % (>=) 97 97 CSA Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed *T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length. 79 HID Electromagnetic Ballasts F24T5/HO # of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 HID Electronic Ballasts 10 Pack 47540 T5 High Output – Programmed Start T5 Electronic Programmed Start For F24 (2 ft), F39 (3 ft), F54 (4 ft), F80 (5 ft) HO T5 Lamps* T5 High Output - UltraStart® Programmed Start ® 2 or 1 – F54T5HO 120 to 277V UltraStart PRS High Temp F Can General characteristics Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 60 Hz Order information 10 Pack 99651 Pallet Pack 99652 DIY Pack General characteristics Electrical characteristics Supply Current Frequency Safety and performance 60 Hz Order information IP Pack 10 Pack 99649 Pallet Pack 99650 UL Type 1 Outdoor UL Type CC System Ballast Factor Ballast Efficacy Factor 0.98 0.98 0.95 1.00 1.00 1.53 2.96 2.87 0.86 0.87 1.00 1.00 1.12 1.12 0.92 0.93 1.70 1.70 UL Listed UL Type HL Power Factor % (>=) 99 98 99 97 99 98 99 97 99 97 99 97 Meets ANSI Standard C62.41-1991 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.68 1.68 1.7 1.7 1.7 1.7 1.7 1.7 UL Class P THD (<=) 1 1 10 1 4.6 7.9 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 Meets ANSI Standard C82.11- cons 2002 RoHS Compliant Lamp # of Lamps Line Volts System Watts Nom. Line Current 4 277 216 0.79 A 3 277 174 0.66 A 2 277 117 0.48 A 1 277 77 0.34 A 4 120 220 1.84 A 3 120 177 1.48 A 2 120 118 0.99 A F54T5WM 1 120 77 0.64 A 4 277 226 0.83 A 3 277 185 0.69 A 2 277 121 0.49 A 1 277 78 0.35 A 4 120 232 1.94 A 3 120 188 1.58 A 2 120 121 1.024 A F54T5HO 1 120 82 0.69 A Other compatible lamps: FT55W/4P, FT50W/4P, FT39W/4P, FC12T5HO, F58T8 Safety and performance ® T5 High Output - UltraStart Programmed Start Dimensions FT55W/4P cUL Listed UL Type CC Min. Starting Temp (°F/°C) 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 5 / -15 UL Listed • Electronic ballasts for all general fluorescent applications • Extends lamp life in frequently switched applications • Reduced lamp replacement cost; ideal for use with occupancy sensors • Slim profile housing Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 16.8 in (428.75 mm) 1.1 in (29.97 mm) 1.2 in (30.48 mm) 16.2 in (411.48 mm) 0.25 in (6.35 mm) Poke-in 18 ft 18 AWG Electronic – Programmed / Rapid Start Programmed start Series – parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, End-of-Life Protection (EOL), Thermally protected Electrical characteristics Supply Current Frequency Wiring diagrams – LFL 62-1, LFL 62-2, LFL 62-3 – see example on page 82 Case dimensions – Ref Drawing -J – see page 83 Length (L) 24 in (609.60 mm) Width (W) 1.2 in (31.49 mm) Height (H) 1.1 in (29.97 mm) Mounting dimensions Mount Length (M) 23.5 in (597.99 mm) Mount Slots (MS) 0.3 in (7.92 mm) Weight 1.78 lbs Exit Type Poke-in Remote Mounting Distance to Lamp 18 ft Remote Mounting Wire Gauge 18 AWG 50 Hz/60 Hz 50 Hz/60 Hz Order information Pallet Pack Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 120 Safety and performance 80 UL Class P THD (<=) 7 9 11 16 6 7 10 13 7 8 12 14 6 8 9 12 DIY Pack 10 Pack 29726 IP Pack System Watts 120 117 63 62 106 103 56 56 90 88 44 44 60 60 Pallet Pack 29717 DIY Pack IP Pack Specifications by lamp and wattage Lamp Nom. Line Current 1.03 A 0.43 A 0.52 A 0.23 A 0.88 A 0.38 A 0.46 A 0.21 A 0.75 A 0.32 A 0.37 A 0.17 A 0.50 A 0.48 A UL Type 1 Outdoor UL Type HL System Ballast Factor 1.00 1.00 1.02 1.02 0.85 0.85 0.87 0.87 1.20 1.20 1.22 1.22 1.12 0.92 Ballast Efficacy Factor 0.83 0.85 1.61 1.64 0.80 0.82 1.55 1.55 1.33 1.36 2.77 2.77 1.86 1.53 FCC – CLASS A Non-Consumer UL Class P Power Factor % (>=) 99 98 99 95 99 98 99 95 99 98 99 90 99 99 UL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 Line Volts 120 277 120 277 120 277 277 120 System Watts 238 233 185 182 122 120 65 64 Safety and performance RoHS Compliant F54T5/HO # of Lamps 4 4 3 3 2 2 1 1 Nom. Line Current 2.00 A 0.86 A 1.52 A 0.66 A 0.99 A 0.43 A 0.24 A 0.52 A UL Type 1 Outdoor System Ballast Factor 1.00 1.00 UL Type CC Ballast Efficacy Factor 0.42 0.42 ANSI – C62.41 UL Type HL Power Factor % (>=) 99 99 99 99 99 98 95 99 Crest Factor (<=) 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 FCC – CLASS A Non-Consumer UL Class P THD (<=) 8 8 8 8 8 12 14 12 cUL Listed Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed CSA See page 195 for warranty information. See page 195 for warranty information. *T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length. 81 HID Electromagnetic Ballasts FT36W/4P Crest Factor (<=) 1.63 1.62 1.61 1.56 1.64 1.62 1.60 1.55 1.64 1.62 1.63 1.56 1.65 1.64 1.62 1.55 HID Electronic Ballasts FC12T5-55W FCC – CLASS A Non-Consumer ANSI-C62.41 General characteristics Wiring diagram – LFL 4b – see example on page 82 Case dimensions – Ref Drawing -D Can – see page 83 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Specifications by lamp and wattage F54T5/HO Power Factor % (>=) 0.98 0.95 0.90 0.81 0.99 0.99 0.99 0.99 0.98 0.97 0.89 0.81 0.99 0.99 0.99 0.99 Compact Fluorescent Ballasts Electronic – Programmed / Rapid Start Programmed start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, End-of-Life Protection (EOL), Thermally protected, Universal voltage Order information # of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 1 1 UL Type HL T5 High Output - UltraStart® Programmed Start Electrical characteristics Lamp UL Type 1 Outdoor Ballast Efficacy Factor 0.46 0.58 0.82 1.46 0.44 0.56 0.81 1.46 0.44 0.55 0.80 1.43 0.41 0.53 0.79 1.36 4, 3, 2 or 1 – F54T5HO 120 to 277 UltraStart® PRS J Can General characteristics 10 Pack 47542 RoHS compliant System Ballast Factor 1.00 1.01 0.96 1.12 0.96 1.00 0.96 1.12 1.00 1.01 0.96 1.12 0.96 1.00 0.96 1.12 29726 – GE454MVPSN1 2 – F54T5HO PRS UNV 50/60 Hz D Can Supply Current Frequency 16.10 in (408.70 mm) 0.25 in (6.35 mm) 3.15 lb Side 8 ft 18 AWG Length (± 1 in) 25 in (636 mm) 34 in (863 mm) 34 in (863 mm) 45 in (1140 mm) 3.5 in (90 mm) Sign Ballasts • Electronic ballasts for all general fluorescent applications • Extends lamp life in frequently switched applications • Reduced lamp replacement cost; ideal for use with occupancy sensors 47542 – B254PUNV-DGE1C Additional Info IP Pack 16.7 in (424.0 mm) 1.7 in (43.2 mm) 1.36 in (34.5 mm) Specifications by lamp and wattage Nom. Line Current 0.99 A 0.43 A 0.61 A 0.27 A 0.98 A 0.43 A 0.60 A 0.26 A 0.91 A 0.40 A 0.56 A 0.25 A FCC – CLASS A Non-Consumer Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating DIY Pack Wiring diagram – LFL 4c – see example on page 82 Case dimensions – Ref Drawing -E – see page 83 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black, White and Grey Red and Blue Red/White and Blue/White Yellow and Orange Green T12 Fluorescent Ballasts # of Lamps Line Volts System Watts 2 120 117 2 277 115 1 120 72 FT50W/4P 1 277 72 2 120 116 2 277 115 1 120 71 F54T5/HO 1 277 71 2 120 109 2 277 107 1 120 66 F54T5WM 1 277 66 Other compatible lamps: FC12T5HO, F58T8, FT39W/4P, FT55W/4P Dimensions Electronic – Programmed / Rapid Start Programmed start Parallel 10% 105°F (41°C) 90°C (194°F) Normal Active A (20-24 decibels) Auto-restart, End-of-Life Protection (EOL), Thermally protected, Anti-striation control Additional Info Specifications by lamp and wattage Lamp 4 – 1 – F54T5HO 120 – 277 UltraStart® PRS High Temp E Can Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Wiring diagram – LFL 4a, LFL 4b – see example on page 82 Case dimensions – Ref Drawing -F – see page 83 Length (L) 11.8 in (298.45 mm) Width (W) 1.7 in (43.18 mm) Height (H) 1.2 in (30.48 mm) Mounting dimensions Mount Length (M) 11.1 in (282.95 mm) Mount Slots (MS) 0.25 in (6.35 mm) Weight 1.85 lbs Exit Type Side Remote Mounting Distance to Lamp 8 ft Remote Mounting Wire Gauge 18 AWG Lead lengths Length (± 1 in) White and Black 25 in (635 mm) Blue and Red 34 in (864 mm) Yellow 45 in (1143 mm) Electrical characteristics Supply Current Frequency T5 High Output - UltraStart® Programmed Start T5 Fluorescent Ballasts Electronic – Programmed / Rapid Start Programmed start Parallel 10% 104°F (40°C) 90°C (194°F) Normal Active A (20-24 decibels) Auto-restart, End-of-Life Protection (EOL), Thermally protected, Universal voltage, Anti-striation control • Lower Maintenance Costs with Parallel Lamp Operation • Fast starting time <700 ms • Auto Restart withstands temporary losses in power without the need to cycle power • UltraCool™ Operation 90C case rating • Bi-Level Switching • Anti-striation control for better light quality, with no striations 99649 – GE454MVPS90-E T8 Fluorescent Ballasts • High Efficiency T5 ballast with Continuous Cathode Cutout Technology • Lower Maintenance Costs with Parallel Lamp Operation • Fast Starting Time <700ms • Multi-Voltage technology means a single ballast handles voltage from 108V to 305V • Auto-Restart withstands temporary losses in power without the need to cycle power • UltraCool™ Operation 90C case rating 99651 – GE254MVPS90-F T5 High Output – Programmed Start T5 Electronic Programmed Start For F24 (2 ft), F39 (3 ft), F54 (4 ft), F80 (5 ft) HO T5 Lamps* Quick Reference Guides gelighting.com Quick Reference Guides gelighting.com Wiring Diagrams T5 Fluorescent Ballasts Case Dimensions T5 Fluorescent Ballasts LFL 4b LFL 4c LFL 62-1 -A Can, -E, -F T8 Fluorescent Ballasts LFL 4a T5 Fluorescent Ballasts -C Can 0.59” T12 Fluorescent Ballasts 1.18” R R Y Y B B G N L 13.75” 14.25” 1.00” Sign Ballasts -D Can LFL 62-2 1.18” Compact Fluorescent Ballasts 0.59” R R Y Y B B G N L 16.28” 16.88” 1.00” -J See page 195 for warranty information. See page 195 for warranty information. *T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length. 83 HID Electromagnetic Ballasts 82 HID Electronic Ballasts LFL 62-3 Quick Reference Guides gelighting.com ProLine® T12 Multivolt 120V – 277V T12 Electronic Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps ProLine® T12 Multivolt 120V – 277V T8 Fluorescent Ballasts • High-performance electronic ballast for all general fluorescent applications • Multi-voltage technology handles voltage from 120 to 277V • Light weight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 24107 – GE-240-RS-MV-N 2 or 1 – F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12 General characteristics Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing ST – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red White and Black Yellow Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information Electronic T12 Std. pack 24107 GE multivolt and dedicated voltage ProLine® T12 high-performance ballasts are designed for replacement of magnetic T12 electronic ballasts during maintenance or retrofits. GE multivolt ProLine® T12 ballasts have the same wiring and mounting requirements as standard magnetic ballasts and provide up to 20% energy savings by simply replacing the ballast. Lamp • Parallel operation — if one lamp fails, others remain lit • Significantly quieter than magnetic • High-frequency operation virtually eliminates lamp flickering typical in T12 electromagnetic systems • Five-year limited ballast warranty • Complete line of ballasts for 2-to-8 foot lamps, circleline and high-output lamps • 100% thermally protected • High-grade lamination steel assures lowest wattage loss • UL, CSA and/or cUL approved • 888-GEBALLAST on every ballast • Two-year limited ballast warranty Color-Coded Ballast and Outer Box Labels 120V – Yellow 277V – Red # of Lamps Line Volts System Watts 2 120 75 2 277 58 1 120 42 F40T10 1 277 42 2 120 74 2 277 73 1 120 48 F40T12 1 277 48 2 120 63 2 277 62 1 120 41 F34T12 1 277 41 2 120 60 2 277 58 1 120 37 F30T12 1 277 37 Other compatible lamps: F20T12, F30T12/WM Safety and performance G E M - 2 Maximum number of lamps supported by this ballast: 1, 2, 3, 4 84 Lamp Watts (Primary Lamp) T8 = 32 – 4 foot, 59 – 8 foot T12 = 40 – 4 foot, 60 – 8 foot T12 Electronic = 40 – 2-4 foot, 2 pin 60 – 4-8 foot, 1 pin 96 – 4-8 foot HO, 2 pin T12 Magnetic = 40 – 2-4 foot, 2 pin 96 – 4-8 foot, 2 pin IS = Instant Start, default if not shown RS = Rapid Start PH = Preheat PT= Preheat/Trigger H = Hybrid D50 = Dimming (min level) HO = High Output VHO = Very High Output 120V – Yellow 277V – Red 220V – Green 240V – Orange 347 – Gray Pack Type IP = Individual corrugated box per ballast 84T = Pallet bulk pack (84=840, 42=420 ballasts) DIY = Shrinkwrap ballast in tray pack DIY72 = Shrinkwrap ballast in pallet pack (Qty) No extension = 10 pack See page 195 for warranty information. Ballast Efficacy 0.89 0.89 1.20 1.21 0.87 0.87 1.38 1.40 UL Type HL UL Class P NRCan Power Factor % (>=) 99 93 99 88 99 94 99 89 99 93 99 86 99 93 99 86 FCC Part 18 Class B at 120 volts cUL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD (<=) 7 16 10 16 7 14 10 17 8 15 10 19 8 16 10 22 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 50 / 10 50 / 10 0 / -18 0 / -18 0 / -18 0 / -18 50 / 10 0 / -18 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 UL Listed RoHS compliant • High-performance electronic ballast for all general fluorescent applications • Light weight, low-profile housing ProLine® T12 120V – 277V 2 – F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12 General characteristics Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Electronic – Programmed / Rapid Start Rapid start Series 10% 221°F (105°C) 70°C (158°F) Normal Passive A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information Std. pack 97498 Pallet Pack DIY Pack 97499 IP Pack Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing B1 – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow Yellow 9.5 in (241.30 mm) 1.3 in (33.02 mm) 1.0 in (25.40 mm) 8.8 in (225.80 mm) 0.9 in (22.35 mm) 0.3 in (7.92 mm) 1.38 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 48 in (1219 mm) 36 in (914 mm) Specifications by lamp and wattage F40T12 FT36W/4P F34T12 F30T12 F12T9 F8T9 F16T9 # of Lamps 2 2 2 2 2 2 2 2 1 1 1 Line Volts 120 120 120 120 120 120 120 120 120 120 120 System Watts 73 73 72 70 63 62 59 59 Safety and performance See page 195 for warranty information. CSA Nom. Line Current 0.62 A 0.62 A 0.62 A 0.60 A 0.54 A 0.53 A 0.50 A 0.50 A UL Type 1 Outdoor System Ballast Factor 1.10 0.85 0.85 0.58 0.85 0.85 0.92 0.53 ANSI – 62.41 UL Type HL Ballast Efficacy 1.50 1.16 1.18 0.82 1.34 1.37 1.55 0.89 Power Factor % (>=) 1 98 98 0.98 98 96 0.92 0.95 FCC Part 18 Class B at 120 volts UL Class P Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 ANSI – C82.11 THD (<=) 20 20 20 20 20 25 25 0.53 UL Listed Min. Starting Temp (°F/°C) 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 NRCan 85 HID Electromagnetic Ballasts GE Ballast M = Electromagnetic Ballast GEH = HID 3 2 - H O - R S - 1 2 0 - D I Y UL Type 1 Outdoor System Ballast Factor 97498 – GE240RS120 Lamp F25T12 GE Ballast LFL magnetic nomenclature Nom. Line Current 0.63 A 0.22 A 0.35 A 0.17 A 0.67 A 0.30 A 0.41 A 0.19 A 0.56 A 0.26 A 0.35 A 0.17 A 0.31 A 0.22 A 0.31 A 0.16 A HID Electronic Ballasts Packaging • Standard 10 packs • IP Packs – individually packed with instructions • DIY – shrink-wrapped and tray-packed with instructions Specifications by lamp and wattage Compact Fluorescent Ballasts Electromagnetic T12 IP Pack Sign Ballasts Performance Features • GE240RSMVN and GE240RS120 comply with FCC for residential use • Low-profile and lightweight housing simplifies installation and reduces transportation costs (GE240 = 1.3 lbs. lighter than magnetic; GE260 = 5.3 lbs. lighter than magnetic) DIY Pack 24773 8.9 in (225.80 mm) 1.7 in (42.92 mm) 0.3 in (7.92 mm) 2.40 lbs Side 18 ft 18 AWG Length (± 1 in) 33 in (838 mm) 25 in (635 mm) 48 in (1219 mm) T12 Fluorescent Ballasts The DOE ballast ruling effective April 1, 2005, prevents the sale of 4 foot and 8 foot lamp electromagnetic ballasts that operate T12 lamps and do not meet federal ballast efficiency requirements. GE ProLine® T12 electronic ballasts meet the DOE minimum ballast efficiency requirements and also allow facility managers to reduce ballast maintenance inventories by consolidating the number of ballasts needed. GE ProLine® T12 ballasts operate both energysaving and standard wattage lamps and are also multi-voltage (120-277V). With 2 ballasts, the multi-voltage ProLine® T12 can consolidate over 40 different magnetic ballasts. Pallet Pack 9.5 in (241.30 mm) 2.4 in (60.45 mm) 1.6 in (39.37 mm) T5 Fluorescent Ballasts Understanding T12 Electronic Ballasts Electronic – Programmed/ Rapid Start Rapid start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Quick Reference Guides gelighting.com ProLine® T12 Multivolt 120V – 277V T12 Electronic Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12, F40T10 Lamps ProLine® T12 Multivolt 120V – 277V T12 Electronic Ballasts For T12 4 ft – 8 ft Slimline Lamps 72110 – GE140RS120-DIY 24108 – GE-260-IS-MV-N ProLine® T12 120V ProLine® T12 Multivolt 120V – 277V 1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack 2 or 1 – F96T12 Instant Start 120 to 277 Dimensions Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information Std. pack Pallet Pack DIY Pack 72110 General characteristics Wiring diagram – LFL 2 – see example on page 102 Case dimensions – Ref Drawing 29 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red White and Black IP Pack 6.46 in (164.08 mm) 1.37 in (34.80 mm) 1.0 in (25.40 mm) 6.0 in (152.40 mm) 1.37 in (34.80 mm) Side Line Volts 120 120 120 120 Safety and performance System Watts 36 36 30 28 Electrical characteristics Order information Std. pack 24108 System Ballast Factor 0.88 1.33 0.88 0.93 cUL Listed Ballast Efficacy Factor 2.44 3.69 2.93 3.32 UL Listed Power Factor % (>=) 57 57 55 58 Crest Factor (<=) 1.58 1.54 1.50 1.51 THD (<=) 150 150 150 150 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 Lamp F96T12 ANSI 62.41 F84T12 F96T12/WM F72T12 F96T12/WMP ProLine® T12 Multivolt 120V – 277V F64T12 3 or 2 – F40 or F34T12 Rapid Start 120 to 277 ProLine® T12 General characteristics DIY Pack 24776 IP Pack Order information DIY Pack 24774 IP Pack F48T12 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) # of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 Line Volts 120 277 120 277 120 277 277 120 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 System Watts 144 140 90 89 126 124 78 77 115 113 72 71 109 107 69 68 101 99 63 63 98 97 62 62 92 91 59 59 73 73 48 48 Safety and performance Nom. Line Current 1.21 A 0.52 A 0.76 A 0.33 A 1.05 A 0.46 A 0.29 A 0.65 A 0.94 A 0.41 A 0.59 A 0.27 A 0.91 A 0.40 A 0.58 A 0.26 A 0.87 A 0.37 A 0.54 A 0.24 A 0.84 A 0.36 A 0.53 A 0.23 A 0.77 A 0.34 A 0.49 A 0.23 A 0.61 A 0.28 A 0.41 A 0.20 A UL Type 1 Outdoor NRCan System Ballast Factor 0.87 0.87 Ballast Efficacy Factor 0.60 0.62 0.90 0.90 0.78 0.79 UL Type HL FCC – CLASS A Non-Consumer Power Factor % (>=) 99 97 99 96 99 98 96 99 99 97 99 95 99 97 99 95 99 97 99 95 99 97 99 95 99 96 99 94 99 95 99 89 UL Class P cUL Listed Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD (<=) 6 14 9 20 8 16 27 10 7 16 10 22 9 17 11 22 9 17 11 22 9 17 11 22 9 18 12 21 10 21 13 27 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 2.40 lbs Side 18 ft 18 AWG Length (± 1 in) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm) 48 in (1219 mm) HID Electronic Ballasts Specifications by lamp and wattage Lamp Safety and performance 86 UL Type 1 Outdoor Nom. Line Current 0.98 A 0.43 A 0.74 A 0.33 A 90.00 A 0.39 A 0.67 A 0.30 A 0.81 A 0.36 A 0.60 A 0.27 A 0.75 A 0.33 A 0.25 A 0.55 A UL Type HL System Ballast Factor 0.89 0.89 Ballast Efficacy Factor 0.78 0.80 0.87 0.87 0.90 0.92 FCC – CLASS A Non-Consumer UL Class P cUL Listed Power Factor % (>=) 99 97 99 96 99 97 99 96 99 96 99 95 99 97 95 99 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD (<=) 5 11 6 12 5 12 6 13 6 12 7 13 5 12 13 6 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 UL Listed See page 195 for warranty information. See page 195 for warranty information. 87 HID Electromagnetic Ballasts # of Lamps Line Volts System Watts 3 120 114 3 277 111 2 120 86 F40T12 2 277 85 3 120 107 3 277 105 2 120 80 F40T10 2 277 79 3 120 96 3 277 94 2 120 71 F34T12 2 277 70 3 120 90 3 277 87 2 277 67 F30T12 2 120 66 Other compatible lamps: F30T12/WM, F40T12/WMP Compact Fluorescent Ballasts Wiring diagram – LFL PS3 – see example on page 101 Case dimensions – Ref Drawing ST – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red Red/White White and Black Yellow 50 Hz/60 Hz Pallet Pack F60T12 Dimensions Electronic – Programmed / Rapid Start Rapid start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Std. pack 24109 Pallet Pack 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 2.40 lbs Side 18 ft 18 AWG Length (± 1 in) 67 in (1702 mm) 59 in (1499 mm) 25 in (635 mm) 25 in (635 mm) Sign Ballasts • High-performance electronic ballasts for all general fluorescent applications • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage 24109 – GE-340-RS-MV-N Supply Current Frequency 50 Hz/60 Hz 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) Specifications by lamp and wattage Nom. Line Current 0.53 A 0.53 A 0.45 A 0.41 A Meets FCC Part 18 (Class B) Consumer Limits Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagram – LFL 14 – see example on page 101 Case dimensions – Ref Drawing ST – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black T12 Fluorescent Ballasts # of Lamps 1 1 1 1 Electronic – Multivolt Instant Start Instant start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Supply Current Frequency Length (± 1 in) 25 in (635 mm) 15 in (381 mm) Specifications by lamp and wattage Lamp F40T12/40W F40T12/25W F34T12/34W F30T12/30W Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T5 Fluorescent Ballasts Electronic – Programmed/ Rapid Start Rapid start Parallel 10% 105°F (41°C) 75°C (167°F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected T8 Fluorescent Ballasts General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • High-performance electronic ballasts for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage Quick Reference Guides gelighting.com T12 Electronic Ballasts T12 High Output T12 Electronic Ballasts T12 High Output For T12 High Output Lamps For T12 High Output Lamps • Electronic ballasts for all general fluorescent applications 80162 – B295SR120HP 72109 – GE296HO-MV-N T12 High Output ProLine® T12 Multivolt 120V – 277V 2 – F96T12HOES RS 120 2 or 1 – F96T12 HO RS 120 to 277 Multivolt ProLine® General characteristics Dimensions Electronic – Programmed / Rapid Start Rapid start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information Std. pack 80162 Pallet Pack DIY Pack General characteristics Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing SL – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow IP Pack 11.75 in (298.45 mm) 3.1 in (79.50 mm) 1.7 in (45.21 mm) 11.4 in (289.81 mm) 2.0 in (50.80 mm) 0.3 in (7.92 mm) 4.00 lbs Side 12 ft 18 AWG Length (± 1 in) 25 in (635 mm) 46 in (1168 mm) 66 in (1676 mm) System Watts 208 185 174 169 Safety and performance Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing SL – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Supply Current Frequency 50 Hz/60 Hz 11.8 in (299.72 mm) 2.15 in (54.61 mm) 1.61 in (40.89 mm) 11.0 in (279.40 mm) 2.15 in (54.61 mm) Side Order information Std. pack 72109 Pallet Pack DIY Pack IP Pack Specifications by lamp and wattage Nom. Line Current 1.77 A 1.60 A 1.47 A 1.40 A UL Type 1 Outdoor System Ballast Factor 0.90 0.89 0.88 0.95 Canadian Energy Standards Ballast Efficacy Factor 0.43 0.48 0.50 0.56 UL Type HL Power Factor % (>=) 99 99 99 99 FCC – CLASS A Non-Consumer Crest Factor (<=) 1.7 1.7 1.7 1.7 UL Class P CSA THD (<=) 10 10 10 10 Min. Starting Temp (°F/°C) -20 / -29 -20 / -29 60 / 16 -20 / -29 UL Listed Lamp F96T12/HO F96T12/HO/ ES/95W F72T12/ HO/85W F60T12/ HO/75W F48T12/ HO/60W # of Lamps 2 2 1 1 2 2 2 2 2 2 2 2 Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 System Watts 196 196 104 104 164 164 154 154 132 132 112 113 Safety and performance cUL Listed Nom. Line Current 1.65 A 0.73 A 0.88 A 0.42 A 1.38 A 0.62 A 1.30 A 0.57 A 1.10 A 0.50 A 0.95 A 0.43 A UL Listed System Ballast Factor 0.90 0.90 0.92 0.92 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 Ballast Efficacy Factor 0.46 0.46 0.88 0.88 0.55 0.55 0.58 0.58 0.68 0.68 0.80 0.80 Power Factor % (>=) 99 97 99 95 99 96 99 96 99 96 99 95 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 THD (<=) 10 10 15 15 10 10 10 10 10 10 15 15 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 FCC Part 18 (Class A) Non Consumer Sign Ballasts • Electronic ballasts for all general fluorescent applications 80163 – B295SR277HP T12 Fluorescent Ballasts Line Volts 120 120 120 120 Electronic – Programmed/ Rapid Start Rapid start Series 10% 105°F (41°C) 75°C (167°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Specifications by lamp and wattage Lamp # of Lamps F96T12/HO 2 F84T12/HO 2 F96T8/HO/WM 2 F72T12/HO 2 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T8 Fluorescent Ballasts T12 High Output 120V Electronic T12 High Output 277V Electronic 2 – F96T12 HOES RS 277 General characteristics Dimensions Electronic – Programmed / Rapid Start Rapid start Series 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing SL – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Order information Std. pack 80163 Pallet Pack DIY Pack IP Pack 11.75 in (298.45 mm) 3.1 in (79.50 mm) 1.7 in (45.21 mm) Compact Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 11.4 in (289.81 mm) 2.0 in (50.80 mm) 0.3 in (7.92 mm) 4.00 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 46 in (1168 mm) 66 in (1676 mm) HID Electronic Ballasts Specifications by lamp and wattage Lamp # of Lamps F96T12/HO 2 F84T12/HO 2 F96T8/HO/WM 2 F72T12/HO 2 Line Volts 277 277 277 277 Safety and performance Nom. Line Current 0.76 A 0.69 A 0.63 A 0.61 A UL Type 1 Outdoor System Ballast Factor 0.90 0.91 0.88 0.95 Canadian Energy Standards Ballast Efficacy Factor 0.43 0.49 0.51 0.56 UL Type HL Power Factor % (>=) 99 99 99 99 FCC – CLASS A Non-Consumer UL Class P Crest Factor (<=) 1.7 1.7 1.7 1.7 CSA THD (<=) 10 10 10 10 Min. Starting Temp (°F/°C) -20 / -29 -20 / -29 60 / 16 -20 / -29 UL Listed See page 195 for warranty information. See page 195 for warranty information. 89 HID Electromagnetic Ballasts 88 System Watts 208 185 174 169 Quick Reference Guides gelighting.com T12 Magnetic Ballasts T12 Magnetic Ballasts For 2 ft Circleline, Preheat T12 Lamps For 2 ft, Circleline, Preheat T12 Lamps • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 89711 – GEM120PH120DIY 1 – F20T12, F15T8, F1512, F14T8, F18T8, 120V, Magnetic Ballast (200H2) 2 – FC12T9, FC16T9, FC8T9, FC12T9, 120V, Magnetic (726VLHWSTCP) General characteristics Dimensions Magnetic – Rapid Start Preheat Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Electrical characteristics Supply Current Frequency 60 Hz Order information Std. pack Pallet Pack DIY Pack 89711 General characteristics Wiring diagram – LFL 21 – see example on page 101 Case dimensions – Ref Drawing 2 – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black IP Pack 3.0 in (77.01 mm) 1.25 in (31.75 mm) 1.75 in (44.45 mm) 3.0 in (77.01 mm) 2.75 in (69.85 mm) 0.2 in (5.58 mm) 0.65 lbs Side 10 ft 18 AWG Length (± 1 in) 9 in (229 mm) Line Volts 120 120 120 120 120 System Watts 18 18 18 18 18 Safety and performance UL Type HL System Ballast Factor 0.84 0.95 0.82 0.65 0.69 cUL Listed Ballast Efficacy Factor 4.66 5.27 4.55 3.61 3.83 CSA Electrical characteristics Order information Std. pack Power Factor % (>=) 48 48 52 57 59 Crest Factor (<=) 1.6 1.6 1.6 1.6 1.6 THD (<=) 10 10 10 10 10 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 1 – F20T12, F15T8, F15T12, F14T12, 120V, Magnetic Ballast (546BTCP) Dimensions A (20-24 decibels) Auto-restart, Thermally protected 60 Hz DIY Pack 89712 IP Pack System Watts 30 Safety and performance UL Type 1 Outdoor UL Type HL System Ballast Factor 0.80 0.96 0.86 1.01 UL Class P UL Type HL System Ballast Factor 0.56 0.45 UL Class P Ballast Efficacy Factor 1.86 cUL Listed Power Factor % (>=) 0.45 0.54 Crest Factor (<=) 1.5 1.5 THD (<=) 10 10 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 UL Listed • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 86227 – GEM1FC8T9RS120IP T12 Magnetic Ballasts Ballast Efficacy Factor 2.75 3.42 3.18 3.88 Power Factor % (>=) 40 39 36 37 6.4 in (163.57 mm) 1.9 in (48.51 mm) 1.9 in (49.27 mm) 6.4 in (163.57 mm) 6.0 in (152.40 mm) 0.25 in (6.35 mm) 2.10 lbs Side 10 ft 18 AWG Length (± 1 in) 10 in (254 mm) 17 in (432 mm) 18 in (457 mm) 14 in (356 mm) Crest Factor (<=) 1.5 1.6 1.6 1.5 THD (<=) 10 10 10 10 Dimensions Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal cUL Listed Wiring diagram – LFL 29 – see example on page 102 Case dimensions – Ref Drawing 9 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Black and White White Blue Red A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information Std. pack Min. Starting Temp (°F/°C) 50 / 10 50 / 10 50 / 10 50 / 10 Pallet Pack DIY Pack 89722 IP Pack 86227 6.4 in (163.57 mm) 1.9 in (48.51 mm) 1.9 in (49.27 mm) 6.4 in (163.57 mm) 6.0 in (152.40 mm) 0.25 in (6.35 mm) 2.10 lbs Side 10 ft 18 AWG Length (± 1 in) 10 in (254 mm) 12 in (305 mm) 10 in (254 mm) 9 in (229 mm) 9 in (229 mm) Specifications by lamp and wattage Lamp FC8T9 FC6T9 # of Lamps 1 1 Line Volts 120 120 System Watts 25 24 Safety and performance UL Type 1 Outdoor Nom. Line Current 0.55 A 0.46 A Nom. Line Current 0.58 A 0.63 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.80 0.81 UL Class P Ballast Efficacy Factor 3.20 3.37 cUL Listed Power Factor % (>=) 50 50 Crest Factor (<=) 1.6 1.6 THD (<=) 10 10 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 UL Listed UL Listed See page 195 for warranty information. See page 195 for warranty information. 91 HID Electromagnetic Ballasts 90 Nom. Line Current 0.59 A 0.59 A 0.62 A 0.59 A Line Volts 120 120 HID Electronic Ballasts Safety and performance System Watts 29 28 27 26 # of Lamps 1 1 Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Line Volts 120 120 120 120 Lamp F16T9 F12T9 General characteristics Wiring diagram – LFL 21 – see example on page 101 Case dimensions – Ref Drawing 9 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black White Blue Red Order information # of Lamps 1 1 1 1 IP Pack Compact Fluorescent Ballasts Magnetic – Rapid Start Trigger start Series 5% 105°F (41°C) 90°C (194°F) Normal Electrical characteristics Lamp F20T12 F15T8 F14T12 F15T12 DIY Pack 89720 1 – FC8T9, FC6T9, RS, 120V, Magnetic Ballast (547RSWSTCP) General characteristics Pallet Pack Pallet Pack 0.30 in (7.87 mm) 2.70 lbs Side 10 ft 18 AWG Length (± 1 in) 12 in (305 mm) 12 in (305 mm) Sign Ballasts • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) T12 Magnetic Ballasts Std. pack 60 Hz 6.5 in (166.62 mm) 6.0 in (152.40 mm) UL Listed 89712 – GEM120TC120DIY Supply Current Frequency A (20-24 decibels) Auto-restart, Thermally protected 6.5 in (166.62 mm) 2.3 in (60.45 mm) 1.6 in (42.92 mm) Specifications by lamp and wattage Nom. Line Current 0.31 A 0.31 A 0.28 A 0.25 A 0.26 A UL Type 1 Outdoor Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagram – LFL 037 – see example on page 102 Case dimensions – Ref Drawing 10 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White Black T12 Fluorescent Ballasts # of Lamps 1 1 1 1 1 Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal Supply Current Frequency Specifications by lamp and wattage Lamp F14T8 F15T12 F15T8 F18T8 F20T12 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T12 Magnetic Ballasts T8 Fluorescent Ballasts T12 Magnetic Ballasts • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 89720 – GEM1FC16T9RS120 Quick Reference Guides gelighting.com T12 Magnetic Ballasts T12 Magnetic Ballasts For 2 ft, Circleline, Preheat T12 Lamps For F30, F34/40 (4 ft) T12 Lamps • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 89717 – GEM1FC12T9RS120 2 – FC12T9, RS, 120V, Magnetic Ballast (449LRWSTCP) 1 – F40T12, F40T12, 120V, Magnetic Ballast (412LSLHTCP) General characteristics Dimensions Magnetic – Rapid Start Rapid start Series 5% 104°F (40°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information Std. pack 89717 Pallet Pack DIY Pack General characteristics Wiring diagram – LFL 037 – see example on page 102 Case dimensions – Ref Drawing D10 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White White and Black White Blue Red IP Pack 11.7 in (297.18 mm) 3.1 in (78.74 mm) 1.8 in (45.72 mm) 11.7 in (297.18 mm) 11.3 in (287.02 mm) 0.30 in (7.62 mm) 2.70 lbs Side 10 ft 18 AWG Length (± 1 in) 10 in (254 mm) 12 in (305 mm) 10 in (254 mm) 9 in (229 mm) 9 in (229 mm) System Watts 49 Safety and performance Nom. Line Current 0.70 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.65 UL Class P Ballast Efficacy Factor 1.33 Power Factor % (>=) 59 Crest Factor (<=) 1.7 THD (<=) 10 Order information Min. Starting Temp (°F/°C) 50 / 10 Safety and performance UL Type 1 Outdoor System Ballast Factor 1.00 1.00 0.97 UL Type HL UL Class P Ballast Efficacy Factor 2.00 2.00 2.25 CSA Power Factor % (>=) 97 97 93 97 Crest Factor (<=) 1.6 1.6 1.6 1.6 THD (<=) 15 15 15 15 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 60 / 16 50 / 10 UL Listed • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 89709 – GEM140RS120DIY T12 Magnetic Ballasts IP Pack 6.5 in (166.62 mm) 2.3 in (60.45 mm) 1.6 in (42.92 mm) 6.5 in (166.62 mm) 6.0 in (152.40 mm) 0.30 in (7.87 mm) 2.50 lbs Side 10 ft 18 AWG Qty Exit 1 Left 1 Left 2 Right 2 Right Dimensions Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal Wiring diagram – LFL 8 – see example on page 102 Case dimensions – Ref Drawing 9 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Red White Blue A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency Length (± 1 in) 10 in (254 mm) 15 in (381 mm) 15 in (381 mm) 18 in (457 mm) 60 Hz Order information Std. pack Pallet Pack DIY Pack 89709 IP Pack 6.4 in (163.57 mm) 1.9 in (48.51 mm) 1.9 in (49.27 mm) 6.4 in (163.57 mm) 6.0 in (152.40 mm) 0.25 in (6.35 mm) 2.10 lbs Side 10 ft 18 AWG Length (± 1 in) 10 in (254 mm) 30 in (762 mm) 36 in (914 mm) 36 in (914 mm) Specifications by lamp and wattage Nom. Line Current 0.59 A 0.63 A 0.60 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.68 0.50 0.64 UL Class P Ballast Efficacy Factor 1.83 1.38 1.77 cUL Listed Power Factor % (>=) 52 48 50 Crest Factor (<=) 1.5 1.4 1.5 THD (<=) 15 15 15 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 50 / 10 UL Listed Lamp F40T12 F30T12 F48T12/25W F34T12 # of Lamps 1 1 1 1 Line Volts 120 120 120 120 System Watts 36 35 32 31 Safety and performance See page 195 for warranty information. See page 195 for warranty information. Nom. Line Current 0.63 A 0.70 A 0.59 A 0.65 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.60 0.67 0.96 0.58 UL Class P Ballast Efficacy Factor 1.66 1.91 3.00 1.87 cUL Listed Power Factor % (>=) 47 42 45 40 Crest Factor (<=) 1.5 1.5 1.5 1.5 THD (<=) 15 15 15 15 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 50 / 10 50 / 10 UL Listed 93 HID Electromagnetic Ballasts 92 System Watts 37 36 36 Nom. Line Current 0.43 A 0.43 A 0.39 A HID Electronic Ballasts Line Volts 120 120 120 System Watts 50 50 43 Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage # of Lamps 2 2 2 Line Volts 120 120 120 120 Compact Fluorescent Ballasts 60 Hz Order information Lamp F20T12 F15T12 F15T8 # of Lamps 1 1 1 1 General characteristics Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing 10 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black White Blue and Red Yellow A (20-24 decibels) Auto-restart, Thermally protected DIY Pack 80819 IP Pack Sign Ballasts Magnetic – Rapid Start Trigger start Series 5% 105°F (41°C) 90°C (194°F) Normal Pallet Pack Lamp F40T10 F40T12 F34T12 F40T12/WMP Safety and performance Dimensions Electrical characteristics Std. pack DIY Pack 89714 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 3.40 lbs Side 10 ft 18 AWG Length (± 1 in) 22 in (559 mm) 26 in (660 mm) 34 in (864 mm) 1 – F40T12, F30T12, F48/25W, 120V, Magnetic Ballast (413CTCP) General characteristics Supply Current Frequency Pallet Pack 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) Specifications by lamp and wattage 2 – F20T12, F15T8, F15T12, F14T12, 120V, Magnetic Ballast (447LRVLHTCP) Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 60 Hz Std. pack • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) T12 Magnetic Ballasts A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics CSA 80819 – GEM220TS120DIY Wiring diagram – LFL 2 – see example on page 102 Case dimensions – Ref Drawing ST – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue Red T12 Fluorescent Ballasts Line Volts 120 Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal Supply Current Frequency Specifications by lamp and wattage Lamp # of Lamps FC8T9/FC12T9 2 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T12 Magnetic Ballasts T8 Fluorescent Ballasts T12 Magnetic Ballasts • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) • Energy saving modified rapid start 89714 – GEM140HRS120DIY Quick Reference Guides gelighting.com T12 Magnetic Ballasts T12 Magnetic Ballasts For F30, F34/40 (4 ft) T12 Lamps For F30, F34/40 (4 ft) T12 Lamps • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 80644 – GEM230RS120DIY 2 – F30T12, 120V, Magnetic Ballast (573LTCP) 2 – F40T12, RS, 120V, Magnetic Ballast (446LSLHTCP) General characteristics Dimensions Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information Std. pack Pallet Pack DIY Pack 80644 General characteristics Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing ST – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red White and Black Yellow IP Pack 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 3.60 lbs Side 10 ft 18 AWG Length (± 1 in) 22 in (559 mm) 20 in (508 mm) 30 in (762 mm) # of Lamps 2 2 Line Volts 120 120 System Watts 64 54 UL Type HL System Ballast Factor 0.80 0.75 UL Class P Electrical characteristics Order information Ballast Efficacy Factor 1.25 1.38 CSA Power Factor % (>=) 95 95 Crest Factor (<=) 1.7 1.7 THD (<=) 20 20 Min. Starting Temp (°F/°C) 50 / 10 60 / 16 UL Listed Lamp F40T10 F40T12 F40T12/WM # of Lamps 2 2 2 Line Volts 120 120 120 DIY Pack 46958 System Watts 87 87 73 Safety and performance 2 – F40T12, F40T12, 120V, Magnetic Ballast (420LTCP) IP Pack 86139 Nom. Line Current 0.73 A 0.73 A 0.64 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.95 0.95 0.89 Circle E Ballast Efficacy Factor 1.09 1.09 1.21 UL Class P Dimensions A (20-24 decibels) Auto-restart, Thermally protected 60 Hz Order information DIY Pack 89710 Safety and performance System Watts 72 72 IP Pack Nom. Line Current 0.62 A 0.62 A UL Type 1 Outdoor T12 Magnetic Ballasts General characteristics Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing ST – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow UL Listed Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 3.40 lbs Side 10 ft 18 AWG Length (± 1 in) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing ST – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red White and Black Yellow Yellow A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information Std. pack Pallet Pack UL Type HL System Ballast Factor 0.84 0.84 UL Class P Ballast Efficacy Factor 1.16 1.16 Power Factor % (>=) 95 95 95 Crest Factor (<=) 1.6 1.6 1.6 THD (<=) 20 20 20 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 50 / 10 DIY Pack 89713 IP Pack 86124 UL Listed 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 3.40 lbs Side 10 ft 18 AWG Length (± 1 in) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) 2 in (51 mm) # of Lamps 2 2 2 Line Volts 277 277 277 System Watts 88 88 74 See page 195 for warranty information. Nom. Line Current 0.32 A 0.32 A 0.27 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.95 0.95 0.88 Circle E Ballast Efficacy Factor 1.07 1.07 1.18 UL Class P CSA Power Factor % (>=) 98 98 97 Crest Factor (<=) 1.6 1.6 1.7 THD (<=) 20 20 20 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 60 / 16 UL Listed 95 HID Electromagnetic Ballasts See page 195 for warranty information. 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) Specifications by lamp and wattage Lamp F40T10 F40T12 F40T12/WM Safety and performance 94 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 60 / 16 HID Electronic Ballasts Line Volts 120 120 120 THD (<=) 20 20 20 • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 86124 – GEM240RS277IP Specifications by lamp and wattage # of Lamps 2 2 2 Crest Factor (<=) 1.6 1.6 1.7 Compact Fluorescent Ballasts Magnetic – Rapid Start Modified rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal Electrical characteristics Lamp F40T10 F40T12 F40T12/WMP CSA Power Factor % (>=) 98 98 95 2 – F40T12, RS, 277V, Magnetic Ballast (443LSLHTCP) General characteristics Pallet Pack Pallet Pack 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 3.40 lbs Side 10 ft 18 AWG Length (± 1 in) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) Sign Ballasts T12 Magnetic Ballasts Std. pack 60 Hz Std. pack • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) • Energy saving modified rapid start 89710 – GEM240HRS120DIY Supply Current Frequency A (20-24 decibels) Auto-restart, Thermally protected 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) Specifications by lamp and wattage Nom. Line Current 0.55 A 0.45 A UL Type 1 Outdoor Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing ST – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow T12 Fluorescent Ballasts Safety and performance Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal Supply Current Frequency Specifications by lamp and wattage Lamp F30T12 F30T12/WM Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T12 Magnetic Ballasts T8 Fluorescent Ballasts T12 Magnetic Ballasts • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 86139 – GEM240RS120IP Quick Reference Guides gelighting.com T12 Magnetic Ballasts T12 Magnetic Ballasts For F30, F34/40 (4 ft) T12 Lamps For T12 4 ft – 8 ft Slimline Lamps • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 86341 – GEM240RS220IP 2 – F40T12, F40T10 220V Magnetic Ballast (754LTCP) 1 – F96T12, IS, 120, Magnetic Ballast (822BRTCP) General characteristics Dimensions Magnetic - Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) High A (20-24 decibels) Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information Std. pack Pallet Pack DIY Pack General characteristics Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing 10 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue and Red Black and White Yellow Yellow IP Pack 86341 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 2.04 lbs Side 10 ft 18 AWG Length (± 1 in) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) 2 in (51 mm) Line Volts 220 Safety and performance System Watts 40 Wiring diagram – LFL 014 – see example on page 103 Case dimensions – Ref Drawing D10 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black/White Red White White and Black Blue B (25-30 decibels) Auto-restart, Thermally protected Electrical characteristics 60 Hz Order information Std. pack Pallet Pack DIY Pack 89719 IP Pack 86372 9.4 in (240.10 mm) 3.0 in (78.58 mm) 1.7 in (45.24 mm) 8.8 in (225.82 mm) 1.69 in (42.86 mm) 0.3 in (7.92 mm) 6.50 lbs Side 10 ft 18 AWG Length (± 1 in) 8 in (203 mm) 44 in (1118 mm) 68 in (1727 mm) 72 in (1829 mm) 48 in (1219 mm) Specifications by lamp and wattage Nom. Line Current UL Type 1 Outdoor UL Type HL System Ballast Factor 0.70 Ballast Efficacy Factor 2 FCC – CLASS A Non-Consumer UL Class P Power Factor % (>=) 90 cUL Listed Crest Factor (<=) 1.7 UL Type CC THD (<=) 32 Min. Starting Temp (°F/°C) 50 / 10 UL Listed Lamp F96T12 F72T12 F96T12/WM # of Lamps 1 1 1 Line Volts 120 120 120 System Watts 93 78 78 Safety and performance Nom. Line Current 0.83 A 0.73 A 0.73 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.75 0.80 0.71 UL Class P Ballast Efficacy Factor 0.80 1.02 0.91 cUL Listed Power Factor % (>=) 93 90 90 Crest Factor (<=) 1.85 1.85 2.00 THD (<=) 30 30 30 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 60 / 16 UL Listed Sign Ballasts • Magnetic ballast construction for all general fluorescent lighting • Instant start ballast for long lamp starting cycles and low initial cost • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 86381 – GEM196IS277IP T12 Magnetic Ballasts T12 Fluorescent Ballasts # of Lamps 2 Magnetic – Standard Instant Start Instant start Series 5% 105°F (41°C) 90°C (194°F) Normal Supply Current Frequency Specifications by lamp and wattage Lamp F40T12 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T12 Magnetic Ballasts T8 Fluorescent Ballasts T12 Magnetic Ballasts • Magnetic ballast construction for all general fluorescent lighting • Instant start ballast for long lamp starting cycles and low initial cost • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 86372 – GEM196IS120IP 1 – F96T12, IS, 277, Magnetic Ballast (828BRTCP) General characteristics Dimensions Magnetic – Standard Instant Start Instant start Series 5% 105°F (41°C) 90°C (194°F) Normal B (25-30 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information Std. pack Pallet Pack DIY Pack IP Pack 86381 9.4 in (240.10 mm) 3.0 in (78.58 mm) 1.7 in (45.24 mm) 8.8 in (225.82 mm) 1.69 in (42.86 mm) 0.3 in (7.92 mm) 6.50 lbs Side 10 ft 18 AWG Qty Exit 1 1 Left 1 Left 1 Right 1 Right Length (± 1 in) 8 in (203 mm) 72 in (1829 mm) 68 in (1727 mm) 48 in (1219 mm) 44 in (1118 mm) Specifications by lamp and wattage Lamp F96T12 F72T12 F96T12/WM # of Lamps 1 1 1 Line Volts 277 277 277 System Watts 93 78 78 Safety and performance See page 195 for warranty information. See page 195 for warranty information. UL Type 1 Outdoor UL Type HL System Ballast Factor 0.75 0.80 0.71 UL Class P Ballast Efficacy Factor 0.80 1.02 0.91 cUL Listed Power Factor % (>=) 90 90 90 Crest Factor (<=) 1.8 1.8 2.0 THD (<=) 30 30 30 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 60 / 16 UL Listed 97 HID Electromagnetic Ballasts 96 Nom. Line Current 0.36 A 0.30 A 0.30 A HID Electronic Ballasts Wiring diagram – LFL 014 – see example on page 103 Case dimensions – Ref Drawing D10 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black/White White and Black White Blue Red Compact Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Quick Reference Guides gelighting.com T12 Magnetic Ballasts T12 Magnetic Ballasts For T12 4 ft – 8 ft Slimline Lamps For T12 High Output Lamps • Magnetic ballast construction for all general fluorescent lighting • Instant start ballast for long lamp starting cycles and low initial cost • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 86360 – GEM296IS120IP 2 – F96T12, IS, 120V, Magnetic Ballast, (806SLHTCP) 2 – F96T12HO, F96T8HO, F72T12HO, RS, 120V, Magnetic Ballast (480SLHTCP) General characteristics Magnetic – Standard Instant Start Instant start Series 5% 105°F (41°C) 90°C (194°F) Normal Electrical characteristics Supply Current Frequency 60 Hz Order information Pallet Pack DIY Pack 46965 IP Pack 86360 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 11.6 in (296.92 mm) 3.0 in (78.48 mm) 1.8 in (45.97 mm) 11.6 in (296.92 mm) 11.25 in (285.75 mm) 0.3 in (7.87 mm) 7.70 lbs Side 10 ft 18 AWG Length (± 1 in) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing 29 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red White and Black Yellow Blue and Red Yellow C (31-36 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information Std. pack Pallet Pack DIY Pack 89718 IP Pack 86164 Specifications by lamp and wattage # of Lamps 2 2 2 2 Line Volts 120 120 120 120 System Watts 158 124 120 98 Safety and performance Nom. Line Current 1.33 A 1.11 A 1.02 A 1.04 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.95 0.94 0.87 0.95 UL Class P Ballast Efficacy Factor 0.60 0.75 0.72 0.96 Circle E CSA Power Factor % (>=) 96 93 95 87 Crest Factor (<=) 1.9 1.8 1.9 1.9 THD (<=) 30 30 30 30 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 60 / 16 50 / 10 UL Listed Specifications by lamp and wattage Lamp # of Lamps F96T12/HO 2 F96T8/HO/WM 2 F72T12/HO 2 Line Volts 120 120 120 System Watts 256 221 208 Safety and performance T12 Magnetic Ballasts 2 – F96T12, IS, 277V, Magnetic Ballast (827SLHTCP) Dimensions B (25-30 decibels) Auto-restart, Thermally protected 60 Hz Order information Pallet Pack UL Class P Circle E T12 Magnetic Ballasts Line Volts 277 277 277 277 DIY Pack 89715 Safety and performance System Watts 158 125 120 98 IP Pack 86379 Nom. Line Current 0.60 A 0.47 A 0.45 A 0.41 A UL Type 1 Outdoor 11.6 in (296.92 mm) 3.0 in (78.48 mm) 1.8 in (45.97 mm) 11.6 in (296.92 mm) 11.25 in (285.75 mm) 0.3 in (7.87 mm) 7.70 lbs Side 10 ft 18 AWG Qty Exit 1 Left 2 Left 1 Right Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal Min. Starting Temp (°F/°C) -20 / -29 60 / 16 -20 / -29 UL Listed Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing 29 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red White and Black Yellow Blue and Red Yellow C (31-36 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency Length (± 1 in) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) 60 Hz Order information Std. pack Pallet Pack UL Type HL System Ballast Factor 0.93 0.95 0.93 0.95 UL Class P Ballast Efficacy Factor 0.58 0.76 0.77 0.96 Circle E CSA Power Factor % (>=) 96 94 95 86 Crest Factor (<=) 1.7 1.8 1.9 1.8 THD (<=) 30 30 30 30 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 60 / 16 50 / 10 DIY Pack IP Pack 86171 UL Listed 11.1 in (283.97 mm) 0.3 in (7.92 mm) 10.90 lbs Side 10 ft 18 AWG Length (± 1 in) 24 in (610 mm) 46 in (1168 mm) 18 in (457 mm) 65 in (1651 mm) 48 in (1219 mm) 72 in (1829 mm) Line Volts 277 277 277 System Watts 248 214 202 See page 195 for warranty information. Nom. Line Current 0.92 A 0.80 A 0.78 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.97 0.95 0.97 UL Class P Ballast Efficacy Factor 0.39 0.44 0.48 Circle E cUL Listed Power Factor % (>=) 98 94 95 Crest Factor (<=) 1.7 1.8 1.8 THD (<=) 20 20 20 Min. Starting Temp (°F/°C) -20 / -29 60 / 16 -20 / -29 UL Listed 99 HID Electromagnetic Ballasts See page 195 for warranty information. 11.75 in (298.45 mm) 3.1 in (80.16 mm) 1.5 in (39.70 mm) Specifications by lamp and wattage Lamp # of Lamps F96T12/HO 2 F96T8/HO/WM 2 F72T12/HO 2 Safety and performance 98 THD (<=) 20 20 20 HID Electronic Ballasts # of Lamps 2 2 2 2 Crest Factor (<=) 1.7 1.8 1.8 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp F96T12 F72T12 F96T12/WM F48T12 cUL Listed Power Factor % (>=) 98 95 97 • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 86171 – GEM296HORS277IP General characteristics Wiring diagram – LFL 025 – see example on page 103 Case dimensions – Ref Drawing 15 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Yellow Blue and Red Electrical characteristics Std. pack UL Type HL Ballast Efficacy Factor 0.38 0.42 0.45 Compact Fluorescent Ballasts Magnetic – Standard Instant Start Instant start Series 5% 105°F (41°C) 90°C (194°F) Normal Supply Current Frequency UL Type 1 Outdoor System Ballast Factor 0.99 0.94 0.95 2 – F96T12HO, F96T8HO, RS, 277V, Magnetic Ballast (487SLHTCP) General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Nom. Line Current 2.14 A 1.94 A 1.81 A Sign Ballasts • Magnetic ballast construction for all general fluorescent lighting • Instant start ballast for long lamp starting cycles and low initial cost • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 86379 – GEM296IS277IP 11.1 in (283.97 mm) 0.3 in (7.92 mm) 10.90 lbs Side 10 ft 18 AWG Length (± 1 in) 24 in (610 mm) 46 in (1168 mm) 18 in (457 mm) 65 in (1651 mm) 48 in (1219 mm) 72 in (1829 mm) T12 Fluorescent Ballasts Lamp F96T12 F72T12 F96T12/WM F48T12 11.75 in (298.45 mm) 3.1 in (80.16 mm) 1.5 in (39.70 mm) T5 Fluorescent Ballasts Wiring diagram – LFL 39 – see example on page 103 Case dimensions – Ref Drawing 15 – see page 105 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black White Blue and Red B (25-30 decibels) Auto-restart, Thermally protected Std. pack General characteristics Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T12 Magnetic Ballasts T8 Fluorescent Ballasts T12 Magnetic Ballasts • Magnetic ballast construction for all general fluorescent lighting • Extends lamp life in frequently switched applications • Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red) 86164 – GEM296HORS120IP T12 Magnetic Ballasts Wiring Diagrams T12 Fluorescent Ballasts For T12 High Output Lamps • Electronic ballasts for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost 80664 – 493B2 LFL PS2 LFL PS3 LFL 14 LFL 21 T8 Fluorescent Ballasts T12 Magnetic Ballasts 2 – F73T12/BL/HO, Suntan, 120, Magnetic Ballast General characteristics Dimensions Electronic – Standard Instant Start Rapid start Series 10% 105°F (41°C) 90°C (194°F) Normal Passive A (20-24 decibels) Thermally protected Wiring diagram – LFL PS2 – see example on page 101 Case dimensions – Ref Drawing ST – see page 104 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red White and Black Yellow Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 80664 Pallet Pack DIY Pack IP Pack 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 2.50 lbs Side 12 ft 18 AWG Length (± 1 in) 36 in (914 mm) 30 in (762 mm) 45 in (1143 mm) T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp F72T12/HO F73T12/HO # of Lamps 2 2 Line Volts 120 120 Nom. Line Current 1.6 A 1.6 A UL Type 1 Outdoor UL Type HL System Ballast Factor 1.00 1.00 Ballast Efficacy Factor 0.55 0.55 FCC – CLASS A Non-Consumer UL Class P Power Factor % (>=) 90 90 CSA Crest Factor (<=) 1.7 1.7 THD (<=) 25 25 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 UL Listed T12 Fluorescent Ballasts Safety and performance System Watts 180 180 Sign Ballasts Fluorescent Accessories Fluorescent Accessories Starters 80619 80620 80621 80622 80629 80623 80624 80625 80627 80628 Description Application FS-2-C FS-4-C FS-5-C FS-25-C FS-12-C BP-SKT BP SL-SS BP-FM BP-LP Starters for 14, 15 & 20 Watt Flu. Lamps Starters for 30 & 40 Watt Flu. Lamps Starters for 4, 6 & 8 Watt Flu. Lamps Starters for 22 & 25 Watt Flu. Lamps Starters for 32 Watt Circular Flu. Lamps Socket Set w/Starter for Bi-Pin Flu. Lamps Socket Set for Bi-Pin Flu. Lamps Socket Set for Slimline Flu. Lamps Face Mount Socket Set for Bi-Pin Flu. Lamps Low-Profile Socket Set for Bi-Pin Flu. Lamps Units Per Carton 24 24 24 24 24 12 12 12 12 12 Compact Fluorescent Ballasts Sockets Prod Code Quick Reference Guides gelighting.com HID Electronic Ballasts See page 195 for warranty information. See page 195 for warranty information. 101 HID Electromagnetic Ballasts 100 Wiring Diagrams T12 Fluorescent Ballasts Wiring Diagrams T12 Fluorescent Ballasts LFL 29 LFL 014 LFL 2 LFL 8 LFL 025 LFL 39 T8 Fluorescent Ballasts LFL 037 Quick Reference Guides gelighting.com T5 Fluorescent Ballasts T12 Fluorescent Ballasts Sign Ballasts Compact Fluorescent Ballasts HID Electronic Ballasts See page 195 for warranty information. See page 195 for warranty information. 103 HID Electromagnetic Ballasts 102 Case Dimensions T12 Fluorescent Ballasts Case Dimensions T12 Fluorescent Ballasts B1 9 SL 2 10 T8 Fluorescent Ballasts ST Quick Reference Guides gelighting.com T5 Fluorescent Ballasts D10, 15, 29 T12 Fluorescent Ballasts Sign Ballasts Compact Fluorescent Ballasts HID Electronic Ballasts See page 195 for warranty information. See page 195 for warranty information. 105 HID Electromagnetic Ballasts 104 Sign Ballasts For T12 High Output Lamps Sign Ballasts T8 Fluorescent Ballasts • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection 72103 – GESB-0412-12-IP T12HO Sign Ballast 4 to 12 ft, 1 to 2 lamps General characteristics Understanding Sign Ballasts Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 72103 Lamp Total Lamp Footage # Code GESB Footage lamps Thermally protected Pallet Pack 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 F72T12/HO F96T12/HO # of Lamps 2 1 1 2 1 2 Line Volts 120 120 120 120 120 120 72103 GESB -0412 -12 IP F48T12/HO F24T12/HO 88921 GESB -0620 -24 IP Safety and performance 88931 GESB -1224 -24 IP 88936 GESB -2040 -24 IP 88920 GESB -1240 -46 IP 88934 GESB -2448 -46 IP -12 IP 88921 GESB -0620 -24 IP 88931 GESB -1224 -24 IP 88936 GESB -2040 -24 IP 88920 GESB -1240 -46 IP 88934 GESB -2448 -46 IP Nom. Line Current 1.48 A 0.92 A 1.03 A 1.13 A 0.82 A 0.90 A UL Type 2 Outdoor UL Listed System Ballast Factor 0.89 0.81 0.84 0.85 0.77 0.78 cUL Listed Ballast Efficacy Factor 0.52 0.81 0.70 0.65 0.96 0.87 Crest Factor (<=) 1.9 2.0 2.0 2.0 2.1 2.1 THD (<=) 15 35 25 20 55 55 Min. Starting Temp (°F/°C) -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 3-Year Warranty • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection General characteristics Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Magnetic – T12 Sign Illuminating Rapid start Series 10% 105°F (41°C) 90°C (194°F) Normal Active Thermally protected Electrical characteristics Supply Current Frequency 50 Hz/60 Hz Pallet Pack DIY Pack IP Pack 11.0 in (279.40 mm) 3.19 in (80.96 mm) 16.00 lbs Side Varies Varies Length (± 1 in) 24 in (610 mm) 80 in (2032 mm) 60 in (1524 mm) 60 in (1524 mm) 72 in (1829 mm) Specifications by lamp and wattage GE Sign Ballast nomenclature G E S B - 0 6 2 0 - 2 4 - I P The last number represents the number of lamps 10 Pack 72104 11.75 in (298.45 mm) 3.19 in (80.96 mm) 2.6 in (67.86 mm) Individual pack # of Lamps 4 3 2 Line Volts 120 120 120 System Watts 300 240 115 Safety and performance Nom. Line Current 2.56 A 2.34 A 1.41 A UL Type 2 Outdoor UL Listed System Ballast Factor 1.06 0.96 0.87 cUL Listed Ballast Efficacy Factor 0.35 0.40 0.76 Power Factor % (>=) 95 99 87 Crest Factor (<=) 1.7 1.8 2.0 THD (<=) 15 15 45 Min. Starting Temp (°F/°C) -20 / -29 -20 / -29 -20 / -29 3-Year Warranty GESB-2040-46-IP can operate a minimum of four lamps at a total length of 20 feet, up to six lamps at a total length of 40 feet. 106 See page 195 for warranty information. See page 195 for warranty information. 107 HID Electromagnetic Ballasts Examples: GESB-0620-24-IP can operate a minimum of two lamps at a total length of 6 feet, up to four lamps at a total length of 20 feet. Lamp F60T12/HO F72T12/HO F36T12/HO HID Electronic Ballasts Wiring diagrams – Sign 0620 – see example on page 118 Case dimensions – Ref Drawing S1 – see page 119 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Brown and Blue Orange/Black Orange, Red and Yellow Blue/White Order information This represents the min/max linear footage of lamps it can operate. Power Factor % (>=) 98 92 96 97 84 84 T12HO Sign Ballast 6 to 20 ft, 2 to 4 lamps 1 2 3 4 5 6 The best way to select or provide cross-reference to competition ballasts is to understand the sign ballast nomenclature. GE Sign Ballast 8.00 lbs Side Varies Varies Length (± 1 in) 24 in (610 mm) 80 in (2032 mm) 60 in (1524 mm) 60 in (1524 mm) 72 in (1829 mm) Compact Fluorescent Ballasts 72103 GESB -0412 System Watts 170 100 120 130 80 90 Sign Ballasts # of Lamps # Code GESB Footage lamps 11.0 in (279.40 mm) 3.19 in (80.96 mm) Sign Ballasts Description IP Pack 72104 – GESB-0620-24-IP Sign Ballast for T12HO, 120 volt GE DIY Pack 11.75 in (298.45 mm) 3.19 in (80.96 mm) 2.6 in (67.86 mm) T12 Fluorescent Ballasts Description Wiring diagrams – Sign 0412 – see example on page 117 Case dimensions – Ref Drawing S1 – see page 119 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Brown and Blue Orange/Black Orange, Red and Yellow Blue/White Specifications by lamp and wattage Sign Ballast for T12HO, 120 volt GE Magnetic – T12 Sign Illuminating Rapid start Series 10% 105°F (41°C) 90°C (194°F) Normal Active T5 Fluorescent Ballasts GE sign ballasts are transitioning from USB to GESB ballast descriptions. These ballasts are electromagnetic technology for T12 high output lamps. The sign ballasts are high output (HO) ballasts for rugged outdoor sign cabinet applications. They will start lamps in cold temperatures down to -20°F. GE sign ballasts are ideal for high moisture environments with a UL Type 2 Outdoor and type HL rating. They are 120-volt series rapid start and have Class P thermal protection. Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Quick Reference Guides gelighting.com Sign Ballasts Sign Ballasts For T12 High Output Lamps For T12 High Output Lamps Sign Ballasts Sign Ballasts T12HO Sign Ballast 12 to 24 ft, 2 to 4 lamps T12HO Sign Ballast 20 to 40 ft, 4 to 6 lamps General characteristics Dimensions Magnetic –T12 Sign Illuminating Rapid start Series 10% 105°F (41°C) 90°C (194°F) Normal Active Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 72105 Pallet Pack DIY Pack General characteristics Wiring diagrams – Sign 1224 – see example on page 118 Case dimensions – Ref Drawing S1 – see page 119 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Brown and Blue Orange/Black Orange, Red and Yellow Blue/White IP Pack 11.75 in (298.45 mm) 3.19 in (80.96 mm) 2.6 in (67.86 mm) 11.0 in (279.40 mm) 3.19 in (80.86 mm) 16.00 lbs Side Varies Varies Length (± 1 in) 24 in (610 mm) 80 in (2032 mm) 60 in (1524 mm) 60 in (1524 mm) 72 in (1829 mm) Line Volts 120 120 120 System Watts 285 230 170 Safety and performance UL Listed System Ballast Factor 0.84 0.82 0.82 Ballast Efficacy Factor 0.29 0.36 0.48 cUL Listed 3-Year Warranty Class P Supply Current Frequency Order information Power Factor % (>=) 99 96 87 Crest Factor (<=) 1.7 1.8 1.9 THD (<=) 10 15 25 Min. Starting Temp (°F/°C) -20 / -29 -20 / -29 -20 / -29 F120T12/HO # of Lamps 4 3 2 Line Volts 120 120 120 System Watts 412 318 225 Nom. Line Current 4.00 A 3.10 A 2.70 A UL Type 2 Outdoor UL Listed System Ballast Factor 0.80 0.82 0.86 cUL Listed Ballast Efficacy Factor 0.19 0.26 0.38 Power Factor % (>=) 98 95 78 Crest Factor (<=) 1.7 1.8 1.8 THD (<=) 15 10 25 Min. Starting Temp (°F/°C) -20 / -29 -20 / -29 -20 / -29 3-Year Warranty • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection Sign Ballasts 60 Hz Order information IP Pack Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 11.75 in (298.45 mm) 3.19 in (80.96 mm) 2.6 in (67.86 mm) 11.0 in (279.40 mm) 3.19 in (80.96 mm) Wiring diagrams – Sign 2448 – see example on page 118 Case dimensions – Ref Drawing S1 – see page 119 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Brown and Blue Orange/Black Orange, Red and Yellow Blue/White Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 72108 Specifications by lamp and wattage Pallet Pack DIY Pack IP Pack 11.75 in (298.45 mm) 3.19 in (80.96 mm) 2.6 in (67.86 mm) 11.0 in (279.40 mm) 3.19 in (80.96 mm) 18.00 lbs Side Varies Varies Length (± 1 in) 24 in (610 mm) 80 in (2032 mm) 60 in (1524 mm) 60 in (1524 mm) 72 in (1829 mm) Specifications by lamp and wattage Line Volts System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) Crest Factor (<=) THD (<=) Min. Starting Temp (°F/°C) 120 120 120 120 415 350 252 183 3.90 A 3.20 A 2.70 A 2.40 A 0.78 0.77 0.78 0.75 0.19 0.22 0.31 0.41 98 95 82 65 1.6 1.7 1.8 1.9 15 10 20 35 -20 / -29 -20 / -29 -20 / -29 -20 / -29 Lamp F96T12/HO F72T12/HO # of Lamps 6 5 5 4 Line Volts 120 120 120 120 System Watts 540 470 370 310 Safety and performance UL Type 2 Outdoor UL Listed cUL Listed Nom. Line Current 4.50 A 3.50 A 3.20 A 3.00 A UL Type 2 Outdoor UL Listed System Ballast Factor 0.86 0.87 0.89 0.89 cUL Listed Ballast Efficacy Factor 0.16 0.19 0.24 0.29 Power Factor % (>=) 96 96 92 85 Crest Factor (<=) 1.6 1.7 1.8 1.8 THD (<=) 10 10 10 20 Min. Starting Temp (°F/°C) -20 / -29 -20 / -29 -20 / -29 -20 / -29 HID Electronic Ballasts 18.00 lbs Side Varies Varies Length (± 1 in) 24 in (610 mm) 80 in (2032 mm) 60 in (1524 mm) 60 in (1524 mm) 72 in (1829 mm) Magnetic – T12 Sign Illuminating Rapid start Series 10% 105°F (41°C) 90°C (194°F) Normal Active Compact Fluorescent Ballasts Thermally protected DIY Pack General characteristics Wiring diagrams – Sign 1240 – see example on page 118 Case dimensions – Ref Drawing S1 – see page 119 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Brown and Blue Orange/Black Orange, Red and Yellow Blue/White Electrical characteristics 3-Year Warranty 3-Year Warranty See page 195 for warranty information. See page 195 for warranty information. 109 HID Electromagnetic Ballasts 108 IP Pack 72108 – GESB-2448-46-IP Dimensions Magnetic - T12 Sign Illuminating Rapid start Series 10% 105°F (41°C) 90°C (194°F) Normal Active Safety and performance DIY Pack 18.00 lbs Side Varies Varies Length (± 1 in) 24 in (610 mm) 80 in (2032 mm) 60 in (1524 mm) 60 in (1524 mm) 72 in (1829 mm) T12HO Sign Ballast 24 to 48 ft, 4 to 6 lamps General characteristics Lamp # of Lamps (2) F96T12/HO + (4) F72T12/HO 6 F72T12/HO 5 F48T12/HO 5 F36T12/HO 4 Lamp Safety and performance T12HO Sign Ballast 12 to 40 ft, 4 to 6 lamps Pallet Pack Pallet Pack 11.0 in (279.40 mm) 3.19 in (80.96 mm) Sign Ballasts Sign Ballasts 10 Pack 72106 60 Hz 10 Pack 72107 • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection 72106 – GESB-1240-46-IP Supply Current Frequency Thermally protected 11.75 in (298.45 mm) 3.19 in (80.96 mm) 2.6 in (67.86 mm) Specifications by lamp and wattage Nom. Line Current 2.70 A 2.10 A 1.60 A UL Type 2 Outdoor Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagrams – Sign 2040 – see example on page 118 Case dimensions – Ref Drawing S1 – see page 119 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Brown and Blue Orange/Black Orange, Red and Yellow Blue/White T12 Fluorescent Ballasts F72T12/HO # of Lamps 4 3 2 Magnetic - T12 Sign Illuminating Rapid start Series 10% 105°F (41°C) 90°C (194°F) Normal Active Electrical characteristics Specifications by lamp and wattage Lamp Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection 72107 – GESB-2040-24-IP T8 Fluorescent Ballasts • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection 72105 – GESB-1224-24-IP Quick Reference Guides gelighting.com Sign Ballasts Sign Ballasts For T12 High Output Lamps For T12 High Output Lamps Sign Ballasts Sign Ballasts 4 to 12 ft, 1 to 2 lamps 16 to 32 ft, 2 to 4 lamps General characteristics Dimensions Magnetic – T12 Sign Illuminating Rapid start Series 105°F (41°C) 90°C (194°F) Normal Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information Pallet Pack DIY Pack General characteristics IP Pack Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagrams – Sign S1A, Sign S2A – see example on page 115 Case dimensions – Ref Drawing S1 – see page 119 Length (L) 10.5 in (268.68 mm) Width (W) 3.19 in (80.96 mm) Height (H) 1.75 in (44.45 mm) Mounting dimensions Bracket Length (BL) 11.7 in (297.25 mm) Mount Length (M) 11.1 in (282.98 mm) Mount Width (X or F) Mount Slots (MS) Weight 8.00 lbs Exit Type Side Remote Mounting Distance to Lamp Varies Remote Mounting Wire Gauge Varies Lead lengths Length (± 1 in) White and Black 24 in (610 mm) Blue and Red 38 in (965 mm) Yellow 48 in (1219 mm) Magnetic – T12 Sign Illuminating Rapid start Series Wiring diagrams – Sign S4A, Sign S6A, Sign S9 – see example on page 115 Case dimensions – Ref Drawing S1 – see page 119 Length (L) 15.625 in (396.87 mm) Width (W) 3.19 in (80.96 mm) Height (H) 2.6 in (67.86 mm) Mounting dimensions Bracket Length (BL) 16.6 in (423.87 mm) Mount Length (M) 16.125 in (409.57 mm) Mount Width (X or F) Mount Slots (MS) Weight 16.00 lbs Exit Type Side Remote Mounting Distance to Lamp Varies Remote Mounting Wire Gauge Varies Lead lengths Length (± 1 in) Blue and Brown 80 in (2032 mm) Yellow 60 in (1524 mm) White and Black 24 in (610 mm) Blue/White 72 in (1829 mm) Red 54 in (1372 mm) 105°F (41°C) 90°C (194°F) Normal Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 88934 Pallet Pack DIY Pack IP Pack Specifications by lamp and wattage Lamp F72T12/HO # of Lamps 2 Line Volts 120 System Watts 160 UL Type 2 Outdoor UL Type HL System Ballast Factor 1.00 CSA Ballast Efficacy Factor 0.62 Power Factor % (>=) 90 Crest Factor (<=) THD (<=) Min. Starting Temp (°F/°C) -20 / -29 Specifications by lamp and wattage Lamp F96T12/HO UL Listed # of Lamps 4 Line Volts 120 System Watts 420 Safety and performance Sign Ballasts 105°F (41°C) 90°C (194°F) Normal Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information Pallet Pack DIY Pack IP Pack Thermally protected 60 Hz Order information Pallet Pack DIY Pack IP Pack Specifications by lamp and wattage Nom. Line Current 1.90 A System Ballast Factor 1.00 Ballast Efficacy Factor 0.45 Power Factor % (>=) 90 Crest Factor (<=) THD (<=) Min. Starting Temp (°F/°C) -20 / -29 Lamp F72T12/HO # of Lamps 4 Line Volts 120 System Watts 325 Safety and performance UL Type 2 Outdoor UL Type HL CSA Nom. Line Current 2.70 A UL Type 2 Outdoor UL Type HL System Ballast Factor 1.00 CSA Ballast Efficacy Factor 0.30 Power Factor % (>=) 90 Crest Factor (<=) THD (<=) Min. Starting Temp (°F/°C) -20 / -29 UL Listed UL Listed See page 195 for warranty information. See page 195 for warranty information. 111 HID Electromagnetic Ballasts 110 105°F (41°C) 90°C (194°F) Normal HID Electronic Ballasts Safety and performance System Watts 220 Wiring diagrams – Sign S1B, Sign S4A, Sign S6A, Sign S9 – see example on page 115 Case dimensions – Ref Drawing S1 – see page 119 Length (L) 13.19 in (334.96 mm) Width (W) 3.19 in (80.96 mm) Height (H) 2.6 in (67.86 mm) Mounting dimensions Bracket Length (BL) 14.3 in (363.52 mm) Mount Length (M) 13.75 in (349.25 mm) Mount Width (X or F) Mount Slots (MS) Weight 14.00 lbs Exit Type Side Remote Mounting Distance to Lamp Varies Remote Mounting Wire Gauge Varies Lead lengths Length (± 1 in) Blue 79 in (2007 mm) Brown 83 in (2108 mm) Yellow 75 in (1905 mm) White and Black 24 in (610 mm) Red 48 in (1219 mm) Blue/White 57 in (1448 mm) Electrical characteristics Specifications by lamp and wattage Line Volts 120 Min. Starting Temp (°F/°C) -20 / -29 Dimensions Magnetic – T12 Sign Illuminating Rapid start Series Supply Current Frequency 10 Pack 88936 THD (<=) • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Supports 1 to 6 lamps, 2 to 48 feet total length • Class P thermal protection General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagrams – Sign S1B, Sign S4A, Sign S6A, Sign S9 – see example on page 115 Case dimensions – Ref Drawing S1 – see page 119 Length (L) 10.5 in (268.68 mm) Width (W) 3.19 in (80.96 mm) Height (H) 2.6 in (67.86 mm) Mounting dimensions Bracket Length (BL) 11.7 in (297.25 mm) Mount Length (M) 11.1 in (282.98 mm) Mount Width (X or F) Mount Slots (MS) Weight 12.00 lbs Exit Type Side Remote Mounting Distance to Lamp Varies Remote Mounting Wire Gauge Varies Lead lengths Length (± 1 in) White and Black 24 in (610 mm) Blue 65 in (1651 mm) White 36 in (914 mm) Yellow 39 in (991 mm) Brown 56 in (1422 mm) Red 40 in (1016 mm) Blue/White 48 in (1219 mm) Crest Factor (<=) Compact Fluorescent Ballasts Magnetic – T12 Sign Illuminating Rapid start Series Power Factor % (>=) 90 UL Listed Sign Ballasts Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info # of Lamps 4 CSA 10 to 24 ft, 1 to 4 lamps General characteristics Lamp F48T12/HO UL Type HL Ballast Efficacy Factor 0.23 88936 – USB-1024-14-IP 8 to 16 ft, 1 to 4 lamps 10 Pack 88931 UL Type 2 Outdoor System Ballast Factor 1.00 Sign Ballasts • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection 88931 – USB-0816-14-IP Nom. Line Current 3.50 A T12 Fluorescent Ballasts Safety and performance Nom. Line Current 1.35 A T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 10 Pack 88921 • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection 88934 – USB-1632-24-IP T8 Fluorescent Ballasts • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection 88921 – USB-0412-12-IP Quick Reference Guides gelighting.com Sign Ballasts Sign Ballasts For T12 High Output Lamps For T12 High Output Lamps Sign Ballasts 20 to 36 ft, 4 to 6 lamps General characteristics Magnetic – T12 Sign Illuminating Rapid start Series Max 3, 2 to 18 ft, 1 to 6 lamps Electrical characteristics 60 Hz Order information Pallet Pack DIY Pack IP Pack Line Volts 120 System Watts 480 Electrical characteristics Order information 10 Pack 88918 Nom. Line Current 4.00 A System Ballast Factor 1.00 Ballast Efficacy Factor 0.20 UL Type 2 Outdoor UL Type HL CSA Power Factor % (>=) 90 Crest Factor (<=) THD (<=) Min. Starting Temp (°F/°C) -20 / -29 General characteristics Thermally protected Electrical characteristics 60 Hz Order information System Watts 240 Pallet Pack DIY Pack UL Type 2 Outdoor UL Type HL System Ballast Factor 1.00 CSA Ballast Efficacy Factor 0.41 Power Factor % (>=) 90 Crest Factor (<=) THD (<=) Min. Starting Temp (°F/°C) -20 / -29 UL Listed IP Pack • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection General characteristics Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Magnetic – T12 Sign Illuminating Rapid start Series Wiring diagrams – Sign S1, Sign S2, Sign S3, Sign S4, Sign S7, Sign S8 – see example on pages 116-117 Case dimensions – Ref Drawing S1 – see page 119 Length (L) 15.625 in (396.87 mm) Width (W) 3.19 in (80.96 mm) Height (H) 2.6 in (67.86 mm) Mounting dimensions Bracket Length (BL) 16.6 in (423.87 mm) Mount Length (M) 16.125 in (409.57 mm) Mount Width (X or F) Mount Slots (MS) Weight 18.00 lbs Exit Type Side Remote Mounting Distance to Lamp Varies Remote Mounting Wire Gauge Varies Lead lengths Length (± 1 in) Blue and Red 80 in (2032 mm) Blue/White and Brown 50 in (1270 mm) Yellow 70 in (1778 mm) White and Black 24 in (610 mm) Orange/Black and Orange 60 in (1524 mm) 105°F (41°C) 90°C (194°F) Normal Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 88919 Pallet Pack DIY Pack IP Pack Specifications by lamp and wattage Nom. Line Current 5.00 A System Ballast Factor 1.00 Ballast Efficacy Factor 0.16 Power Factor % (>=) 90 Crest Factor (<=) THD (<=) Min. Starting Temp (°F/°C) -20 / -29 Lamp F96T12/HO # of Lamps 6 Line Volts 120 System Watts 570 Safety and performance UL Type 2 Outdoor UL Type HL CSA Nom. Line Current 4.80 A UL Type 2 Outdoor UL Type HL System Ballast Factor 1.00 CSA Ballast Efficacy Factor 0.17 Power Factor % (>=) 90 Crest Factor (<=) THD (<=) Min. Starting Temp (°F/°C) -20 / -29 UL Listed HID Electronic Ballasts System Watts 600 Nom. Line Current 2.00 A Max 3, 10 to 48 ft, 1 to 6 lamps Specifications by lamp and wattage UL Listed See page 195 for warranty information. See page 195 for warranty information. 113 HID Electromagnetic Ballasts 112 Line Volts 120 Sign Ballasts Wiring diagrams – Sign S5A, Sign S7, Sign S7A – see example on pages 116-117 Case dimensions – Ref Drawing S1 – see page 119 Length (L) 15.625 in (396.87 mm) Width (W) 3.19 in (80.96 mm) Height (H) 2.6 in (67.86 mm) Mounting dimensions Bracket Length (BL) 16.6 in (423.87 mm) Mount Length (M) 16.125 in (409.57 mm) Mount Width (X or F) Mount Slots (MS) Weight 18.00 lbs Exit Type Side Remote Mounting Distance to Lamp Varies Remote Mounting Wire Gauge Varies Lead lengths Length (± 1 in) Blue/White 50 in (1270 mm) Brown and Orange 50 in (1270 mm) Orange/Black 50 in (1270 mm) White and Black 24 in (610 mm) Blue and Red 80 in (2032 mm) Yellow 70 in (1778 mm) 105°F (41°C) 90°C (194°F) Normal Safety and performance # of Lamps 6 Compact Fluorescent Ballasts Magnetic – T12 Sign Illuminating Rapid start Series Line Volts 120 Lamp F36T12/HO 88919 – USB-1048-16-IP Dimensions Supply Current Frequency IP Pack Sign Ballasts • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL type 2 outdoor and HL rating • Supports 1 to 6 lamps, 2 to 48 feet total length • Class P thermal protection 20 to 48 ft, 4 to 6 lamps Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info DIY Pack UL Listed Sign Ballasts # of Lamps 6 Pallet Pack Specifications by lamp and wattage 88940 – USB-2048-46-IP Lamp F96T12/HO 60 Hz Safety and performance Safety and performance 10 Pack 88940 Thermally protected T12 Fluorescent Ballasts # of Lamps 6 Wiring diagrams – Sign S3, Sign S4, Sign S5, Sign S6, Sign S7, Sign S8 – see example on pages 116-117 Case dimensions – Ref Drawing S1 – see page 119 Length (L) 13.19 in (334.96 mm) Width (W) 3.19 in (80.96 mm) Height (H) 2.6 in (67.86 mm) Mounting dimensions Bracket Length (BL) 14.3 in (363.52 mm) Mount Length (M) 13.75 in (349.25 mm) Mount Width (X or F) Mount Slots (MS) Weight 15.00 lbs Exit Type Side Remote Mounting Distance to Lamp Varies Remote Mounting Wire Gauge Varies Lead lengths Length (± 1 in) White and Black 24 in (610 mm) Brown, Blue and Red 60 in (1524 mm) Orange/Black 60 in (1524 mm) Orange and Yellow 60 in (1524 mm) Blue/White 60 in (1524 mm) 105°F (41°C) 90°C (194°F) Normal Supply Current Frequency Specifications by lamp and wattage Lamp F72T12/HO Dimensions Magnetic – T12 Sign Illuminating Rapid start Series T5 Fluorescent Ballasts Thermally protected Supply Current Frequency General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Wiring diagrams – Sign S5A, Sign S7, Sign S7A – see example on pages 116-117 Case dimensions – Ref Drawing S1 – see page 119 Length (L) 15.625 in (396.87 mm) Width (W) 3.19 in (80.96 mm) Height (H) 2.6 in (67.86 mm) Mounting dimensions Bracket Length (BL) 16.6 in (423.87 mm) Mount Length (M) 16.125 in (409.57 mm) Mount Width (X or F) Mount Slots (MS) Weight 18.00 lbs Exit Type Side Remote Mounting Distance to Lamp Varies Remote Mounting Wire Gauge Varies Lead lengths Length (± 1 in) Orange and Blue 50 in (1270 mm) Orange/Black 50 in (1270 mm) Red 80 in (2032 mm) Yellow 70 in (1778 mm) Blue/White and Brown 38 in (965 mm) White and Black 24 in (610 mm) 105°F (41°C) 90°C (194°F) Normal 10 Pack 88939 Sign Ballasts Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection 88918 – USB-0218-16-IP T8 Fluorescent Ballasts • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Supports 1 to 6 lamps, 2 to 48 feet total length • Class P thermal protection 88939 – USB-2036-46-IP Quick Reference Guides gelighting.com Sign Ballasts Wiring Diagrams Sign Ballasts For T12 High Output Lamps Sign Ballasts SIGN S1A SIGN S2A SIGN S1B SIGN S4A SIGN S6A SIGN S9 T8 Fluorescent Ballasts • High-output ballasts for rugged outdoor sign cabinet applications • Reliable low-temperature starting – as low as -20°F • Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating • Class P thermal protection 88920 – USB-1232-16-IP Max 3, 12 to 32 ft, 1 to 6 lamps General characteristics Dimensions Magnetic – T12 Sign Illuminating Rapid start Series Wiring diagrams – Sign S3, Sign S4, Sign S5, Sign S6, Sign S7, Sign S8 – see example on pages 116-117 Case dimensions – Ref Drawing S1 – see page 119 Length (L) 13.19 in (334.96 mm) Width (W) 3.19 in (80.96 mm) Height (H) 2.6 in (67.86 mm) Mounting dimensions Bracket Length (BL) 14.3 in (363.52 mm) Mount Length (M) 13.75 in (349.25 mm) Mount Width (X or F) Mount Slots (MS) Weight 16.00 lbs Exit Type Side Remote Mounting Distance to Lamp Varies Remote Mounting Wire Gauge Varies Lead lengths Length (± 1 in) White and Black 24 in (610 mm) Brown and Blue 80 in (2032 mm) Orange/Black 60 in (1524 mm) Orange, Red and Yellow 60 in (1524 mm) Blue/White 72 in (1829 mm) 105°F (41°C) 90°C (194°F) Normal Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 88920 Pallet Pack DIY Pack IP Pack T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage # of Lamps 6 Line Volts 120 Safety and performance System Watts 410 Nom. Line Current 3.50 A UL Type 2 Outdoor UL Type HL System Ballast Factor 1.00 CSA Ballast Efficacy Factor 0.24 Power Factor % (>=) 90 Crest Factor (<=) THD (<=) Min. Starting Temp (°F/°C) -20 / -29 UL Listed T12 Fluorescent Ballasts Lamp F48T12/HO Quick Reference Guides gelighting.com Sign Ballasts Compact Fluorescent Ballasts HID Electronic Ballasts See page 195 for warranty information. See page 195 for warranty information. 115 HID Electromagnetic Ballasts 114 Wiring Diagrams Sign Ballasts SIGN S5A Wiring Diagrams Sign Ballasts SIGN S7A SIGN S6 SIGN S7 SIGN S8 T8 Fluorescent Ballasts SIGN S5 Quick Reference Guides gelighting.com T5 Fluorescent Ballasts SIGN S3 SIGN S4 Sign Ballasts SIGN S2 T12 Fluorescent Ballasts SIGN S1 Compact Fluorescent Ballasts SIGN 0412 LINE BLACK WHITE Ballast RED RED LINE BLACK WHITE Ballast YELLOW YELLOW BLUE BLUE HID Electronic Ballasts YELLOW YELLOW BLUE BLUE RED RED Lamp 1 Lamp 2 See page 195 for warranty information. See page 195 for warranty information. 117 HID Electromagnetic Ballasts 116 Lamp 1 Wiring Diagrams Sign Ballasts Case Dimensions Sign Ballasts SIGN 0620 S1 BLUE BLUE Ballast BLACK WHITE LINE BLUE BLUE Ballast BLACK WHITE LINE T8 Fluorescent Ballasts BLACK WHITE LINE BLUE BLUE Ballast BROWN BROWN BLUE/WHITE BLUE/WHITE BROWN BROWN BLUE/WHITE BLUE/WHITE BROWN BROWN BLUE/WHITE BLUE/WHITE YELLOW YELLOW RED RED YELLOW YELLOW RED RED YELLOW YELLOW RED RED Lamp 1 Lamp 1 Lamp 2 Lamp 1 Lamp 2 Lamp 3 Lamp 2 Lamp 3 Lamp 4 T5 Fluorescent Ballasts SIGN 1224 BLACK WHITE LINE BLUE BLUE Ballast BLACK WHITE LINE BLUE BLUE Ballast BLACK WHITE LINE BLUE BLUE Ballast BROWN BROWN BLUE/WHITE BLUE/WHITE BROWN BROWN BLUE/WHITE BLUE/WHITE BROWN BROWN BLUE/WHITE BLUE/WHITE YELLOW YELLOW RED RED YELLOW YELLOW RED RED YELLOW YELLOW RED RED Quick Reference Guides gelighting.com Lamp 1 Lamp 2 Lamp 2 Lamp 3 Lamp 2 Lamp 3 Lamp 4 T12 Fluorescent Ballasts Lamp 1 Lamp 1 SIGN 1240 LINE BLACK WHITE BROWN BROWN Ballast BLUE BLUE LINE BLACK WHITE OR BLK OR BLK BROWN BROWN BLUE WH BLUE WH ORAN E ORAN E YELLOW YELLOW RED RED Ballast BLUE BLUE LINE BLACK WHITE Ballast BLUE BLUE OR BLK OR BLK BROWN BROWN BLUE WH BLUE WH ORAN E ORAN E BLUE WH BLUE WH ORAN E ORAN E YELLOW YELLOW RED RED YELLOW YELLOW RED RED Lamp 1 Lamp 1 Lamp 2 Lamp 2 Lamp 3 Lamp 3 Lamp 3 Lamp 4 Lamp 4 Lamp Lamp Lamp Sign Ballasts Lamp 1 OR BLK OR BLK Lamp 2 Lamp 4 Compact Fluorescent Ballasts SIGN 2040 BLACK WHITE LINE Ballast BLUE BLUE LINE BLACK WHITE Ballast BLUE BLUE LINE BLACK WHITE Ballast BLUE BLUE BROWN BROWN BLUE/WHITE BLUE/WHITE BROWN BROWN BLUE/WHITE BLUE/WHITE BROWN BROWN BLUE/WHITE BLUE/WHITE YELLOW YELLOW RED RED YELLOW YELLOW RED RED YELLOW YELLOW RED RED Lamp 1 Lamp 1 Lamp 2 Lamp 2 Lamp 3 Lamp 3 Lamp 4 HID Electronic Ballasts Lamp 2 Lamp 1 SIGN 2448 LINE BLACK WHITE BROWN BROWN Ballast BLUE BLUE LINE BLACK WHITE OR BLK OR BLK BROWN BROWN BLUE WH BLUE WH ORAN E ORAN E YELLOW YELLOW RED RED Ballast BLUE BLUE LINE BLACK WHITE Ballast BLUE BLUE OR BLK OR BLK BROWN BROWN BLUE WH BLUE WH ORAN E ORAN E BLUE WH BLUE WH ORAN E ORAN E YELLOW YELLOW RED RED YELLOW YELLOW RED RED Lamp 1 Lamp 1 Lamp 2 Lamp 2 Lamp 3 Lamp 3 Lamp 3 Lamp 4 Lamp 4 Lamp Lamp Lamp Lamp 2 Lamp 4 118 See page 195 for warranty information. See page 195 for warranty information. 119 HID Electromagnetic Ballasts Lamp 1 OR BLK OR BLK GE Multivolt ProLine® CFL Multi-Lamp Capability GE compact fluorescent (CFL) ballasts provide energy saving alternatives to halogen, incandescent or HID light sources. GE Multivolt ProLine® CFL programmed start ballasts combine universal voltage (108-305V) technology with multi-lamp capability, dual entry color-coded connectors and ultra system reliability to create an industry leading CFL solution for commercial and residential applications. T5 Circleline FT TT5 Multivolt ProLine® CFL ballasts come with a five-year ballast and one-year lamp limited warranty. These ballasts also meet the EPA’s ENERGY STAR® fixture program requirements with a Consumer Class B EMI rating for residential applications, as well as a high power factor ballast design. T5 GEC242MVPS X X X X X X X GEC240-MV X X X X X X X X X X X X X X X X X X X X X X X X X X X CFL – Cross Reference Chart Universal Advance Osram Robertson ESI GE213-MVPS-3W C213UNVSE/BE/BES ICF-2513-H1-LD QTP 1/2X13CF/UNV PSM213CQMY ES-2/1-CFQ-13/10-UNV-C/D ES-1-2D-16/10-UNV-D GE218-MVPS-3W C218UNVSE/BE/BES ICF-2518-H1-LD REL-2Q18 VEL-2Q18 R-2Q18-4P-TP V-2Q18-4P-TP QTP 1/2X18CF/UNV PSM218CQMY ES-2/1-CFQ-18-UNV-C/D ES-1-2D-21-UNV-D GE226-MVPS-3W C2642UNVSE/BE/BES C226SR120BE C226SR277BE ICF-2526-H1-LD REL-1T32 VEL-1T32 REL-1T42 VEL-1T42 QTP 2X26/UNV QTP 1/2XCF/UNV PSM226CQMY ES-2/1-CFQ-26-UNV-C/D ES-1-CFH-42/32/26-UNV-C/D ES-1-T5C-40/22-UNV-D HID Electronic Ballasts GE Compact Fluorescent Ballast nomenclature G E C 2 1 3 - M V P S - S E GE Compact Ballast 120 SE = Side & Bottom Entry BES = Bottom Entry with Studs 3W = 3-Way Kit (SE, BE, BES) IP = Individual Pack PS = Programmed Start SI = Series Instant Start PH = Preheat. RS = Rapid Start RH = less than 20% THD See page 195 for warranty information. See page 195 for warranty information. 121 HID Electromagnetic Ballasts Max number of lamps and Primary Lamp type MV = Multivolt (108 to 305 volts) UNV = Universal Voltage (Multi-Voltage) 120 or 277 = voltage Compact Fluorescent Ballasts GE Sign Ballasts Use the GE Multivolt ProLine® CFL Multi-Lamp compatibility chart (page 121) to find the right ballast for your need. 2D X X X GEC226-MVPS T12 Fluorescent Ballasts Multivolt ProLine® CFL ballasts are offered in three different configurations: 1) -SE description – dual entry (side or bottom) connectors, 2) -BES – bottom entry with studs for mounting to junction boxes and 3) -3W – 3-way mounting kits that allow you to have all three mounting options with one kit. GEC218-MVPS T5 Fluorescent Ballasts Understanding Compact Fluorescent Ballasts GEC213-MVPS X X X T8 Fluorescent Ballasts T4 Lamp Type 1 x 13W (CFQ/G24q, CFTR/GX24q) 2 x 13W (CFQ/G24q, CFTR/GX24q) 1 x 18W (CFQ/G24q, CFTR/GX24q) 2 x 18W (CFQ/G24q, CFTR/GX24q) 1 x 26W (CFQ/G24q, CFTR/GX24q) 2 x 26W (CFQ/G24q, CFTR/GX24q) 1 x 32W (CFQ/G24q, CFTR/GX24q) 2 x 32W (CFQ/G24q, CFTR/GX24q) 1 x 42W (CFQ/G24q, CFTR/GX24q) 2 x 42W (CFQ/G24q, CFTR/GX24q) 1 x 22W (FC9T5) 1 x 22W (FC9T5) 1 x 22W + 1 x 40W (FC9T5 + FC12T5) 1 x FC16T9 2 x 24 / 27W (FT/2G11) 1 x FT36W (2G11) 2 x FT36W (2G11) 1 x 40W (FT/2G11) & Energy Saving 28W 2 x 40W (FT/2G11) & Energy Saving 28W 3 x 40W (FT/2G11) & Energy Saving 28W 1 x 10W (CFS/GR10q) 2 x 10W (CFS/GR10q) 1 x 16W (CFS/GR10q) 2 x 16W (CFS/GR10q) 1 x 21W (CFS/GR10q) 2 x 21W (CFS/GR10q) 1 x 28W (CFS/GR10q) 2 x 28W (CFS/GR10q) 1 x 38W (CFS/GR10q) 2 x 38W (CFS/GR10q) 1 x 57W (CFTR/GX24q) 1 x 70W (CFTR/GX24q) Quick Reference Guides gelighting.com ProLine® CFL Electronic Ballasts Specifications: Multivolt ProLine® CFL Quick Reference Chart Lamp Type CFTR13W/GX24q CFQ18W/GX24q CFTR18W/GX24q GEC213-MVPS-xx CFS16W/GR10q CFTR18W/GX24q CFQ26W/G24q GFTR26W/GX24q CFS16W/GR10q GEC218-MVPS-xx CFS28W/GR10q CFTR26W/GX24q CFTR42W/GX24q CFT32W/GX24q FT24W/2G11 GEC226-MVPS-xx FC16T9/40W ProLine® CFL Electronic Ballasts 2 or 1 – CFQ13W/G24q 120-227V ProLine® PS General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Supply Current Frequency 50 Hz/60 Hz 5.0 in (127.00 mm) 2.4 in (60.96 mm) 1.0 in (25.40 mm) 4.63 in (117.60 mm) 2.4 in (60.96 mm) 0.57 lbs Dual Entry (SE/BE, BES, 3W) 20 ft 18 AWG Order information 10 Pack 71428, 71429, 71430 Pallet Pack DIY Pack IP Pack Specifications by lamp and wattage Lamp # of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor 2 120 31 0.26 A 1.00 2 277 31 0.12 A 1.00 2 120 30 0.25 A 1.00 F13T5 2 277 30 0.11 A 1.00 2 120 29 0.25 A 1.00 2 277 29 0.11 A 1.00 CFTR13W/ 1 120 16 0.16 A 1.00 1 277 16 0.06 A 1.00 GX24q 2 120 29 0.25 A 1.00 2 277 29 0.11 A 1.00 1 120 16 0.16 A 1.00 CFQ13W/G24q 1 277 16 0.06 A 1.00 Other compatible lamps: CFQ18W/G24q, CFTR18W/GX24q, CFS16W/GR10q, CFS10W/GR10q F14T5 Safety and performance UL Type 1 Outdoor FCC Part 18 Class B at 120 Volts Ballast Efficacy Factor 3.23 3.23 3.33 3.33 3.45 3.45 6.25 6.25 3.45 3.45 6.25 6.25 UL Type HL Power Factor % (>=) 99 98 99 98 99 99 96 96 99 99 96 96 FCC – CLASS B Consumer Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Class P CSA THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10 Min. Starting Temp (°F/°C) -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 UL Type CC UL Listed • Multi-voltage technology means a single ballast handles voltage from 108V to 305V • Programmed starting for extended lamp life • End-of-Lamp-Life protection • Color coded poke-in connectors simplifies wiring 71432 – GEC218-MVPS-BES 71433 – GEC218-MVPS-SE 71434 – GEC218-MVPS-3W ProLine® CFL Electronic Ballasts 2 or 1 – CFQ18W/G24q 120-227V ProLine® PS Dimensions General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Electronic – Program / Rapid start Programmed start Series 10% 104°F (40°C) 70°C (158 °F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected, Universal voltage Wiring diagram – CFL 1-2 – see example on page 132 Case dimensions – Ref Drawing -13 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Electrical characteristics Supply Current Frequency 50 Hz/60 Hz 5.0 in (127.00 mm) 2.4 in (60.96 mm) 1.0 in (25.40 mm) 4.63 in (117.60 mm) 2.4 in (60.96 mm) 1.10 lbs Dual Entry (SE/BE, BES, 3W) 20 ft 18 AWG Order information 10 Pack 71432, 71433, 71434 Pallet Pack DIY Pack IP Pack Specifications by lamp and wattage Lamp # of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor 2 120 40 0.33 A 0.91 2 277 40 0.14 A 0.91 CFS21W/ 1 120 20 0.16 A 0.9 GR10q 1 277 20 0.07 A 0.9 2 120 39 0.33 A 1.05 2 277 39 0.14 A 1.05 CFTR18W/ 1 120 20 0.17 A 1.05 GX24q 1 277 20 0.08 A 1.05 CFS16W/ 2 120 37 0.31 A 1.00 2 277 37 0.13 A 1.00 GR10q Other compatible lamps: CFTR26W/GX24q, CFQ26W/G24q, CFS28W/GR10q, CFQ18W/G24q See page 195 for warranty information. UL Type 1 Outdoor FCC Part 18 Class B at 120 volts Ballast Efficacy Factor 2.28 2.28 4.50 4.50 2.69 2.69 5.25 5.25 2.70 2.70 FCC – CLASS B Consumer Power Factor % (>=) 99 99 97 97 97 97 97 97 99 99 UL Type HL UL Class P Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 CSA THD (<=) 10 10 15 15 10 10 10 10 10 10 UL Type CC Min. Starting Temp (°F/°C) -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 UL Listed 123 HID Electromagnetic Ballasts See page 195 for warranty information. Wiring diagram – CFL 1-2 – see example on page 132 Case dimensions – Ref Drawing -13 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Electrical characteristics Safety and performance 122 Dimensions Electronic – Program / Rapid Start Programmed start Series 10% 104°F (40°C) 70 °C (158 °F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected, Universal voltage HID Electronic Ballasts CFS21W/GR10q • Multi-voltage technology means a single ballast handles voltage from 108V to 305V • Programmed starting for extended lamp life • End-of-Lamp-Life protection • Color coded poke-in connectors simplifies wiring 71428 – GEC213-MVPS-BES 71429 – GEC213-MVPS-SE 71430 – GEC213-MVPS-3W Compact Fluorescent Ballasts CFQ26W/G24q For 13 – 42W T4 CFL Lamps Sign Ballasts CFS21W/GR10q Ballast Efficiency Factor 3.45 3.45 6.25 6.25 3.45 3.45 6.25 6.25 5.00 5.00 5.00 5.00 4.13 4.13 8.08 8.08 5.88 5.88 2.71 2.71 5.26 5.26 2.69 2.69 5.25 5.25 3.57 3.57 3.57 3.57 2.28 2.28 4.5 4.5 2.70 2.70 3.23 3.23 1.96 1.96 3.7 3.7 1.85 1.85 3.79 3.79 2.13 2.13 2.72 2.72 2.20 2.20 1.94 1.94 2.33 2.33 T12 Fluorescent Ballasts GFQ18W/G24q Max THD% 10 10 10 10 10 10 10 10 12 12 12 12 11 11 14 14 12 12 10 10 10 10 10 10 10 10 12 12 12 12 10 10 15 15 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Ballast Factor 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.95 0.95 1.05 1.05 1.0 1.0 0.95 0.95 1.0 1.0 1.05 1.05 1.05 1.05 1.0 1.0 1.0 1.0 0.91 0.91 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.10 1.10 0.98 0.98 0.98 0.98 1.12 1.12 0.93 0.93 1.00 1.00 T5 Fluorescent Ballasts CFS10W/GR10q Power Factor 0.99 0.99 0.96 0.96 0.99 0.99 0.96 0.96 0.99 0.97 0.99 0.97 0.97 0.97 0.96 0.96 0.96 0.96 0.99 0.99 0.97 0.97 0.97 0.99 0.97 0.97 0.99 0.96 0.99 0.96 0.99 0.99 0.97 0.97 0.99 0.99 0.99 0.97 0.99 0.99 0.98 0.98 0.99 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.99 0.99 0.99 0.99 0.99 0.97 T8 Fluorescent Ballasts CFQ13W/GX4q SE BES 3W (Side and (Bottom (3-Way Bottom Exit with Mounting # of Lamps Input Volts Entry) Studs) Kit) Input Watts Line Current 120 29 0.25 2 277 29 0.11 120 16 0.16 1 177 16 0.06 120 29 0.25 2 277 29 0.11 120 16 0.16 1 277 16 0.06 120 20 0.17 1 277 20 0.07 120 20 0.17 1 277 20 0.07 120 23 0.19 2 277 23 0.09 120 13 0.11 1 277 13 0.05 120 17 0.14 1 277 17 0.06 71429 71428 71430 35 0.3 120 277 35 0.13 2 120 19 0.16 1 277 19 0.07 120 39 0.33 2 277 39 0.14 120 20 0.17 1 277 20 0.08 120 28 0.24 1 277 28 0.10 120 28 0.24 1 277 28 0.10 120 40 0.33 2 277 40 0.14 120 20 0.16 1 277 20 0.07 120 37 0.31 2 277 37 0.13 120 31 0.26 1 277 31 0.11 71433 71432 71434 120 51 0.43 2 277 51 0.19 120 27 0.23 1 277 27 0.10 120 54 0.45 2 277 54 0.20 120 29 0.24 1 277 29 0.11 120 46 0.38 1 277 46 0.17 120 36 0.031 1 277 36 0.013 120 51 0.042 2 277 51 0.18 120 48 0.41 2 277 48 0.18 120 43 0.36 71444 71443 71445 1 277 43 0.16 Quick Reference Guides gelighting.com ProLine® CFL Electronic Ballasts ProLine® CFL Electronic Ballasts For 13 – 42W T4 CFL Lamps For 40W Biax® CFL Ballasts ProLine CFL Electronic Ballasts General characteristics General characteristics Dimensions Wiring diagram – CFL 1-2 – see example on page 132 Case dimensions – Ref Drawing 13 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Electrical characteristics 50 Hz/60 Hz 5.0 in (127.00 mm) 2.4 in (60.96 mm) 1.0 in (25.40 mm) Electronic – Program / Rapid Start Programmed start Series 10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected, Universal voltage Wiring diagram – CFL 20C – see example on page 131 Case dimensions – Ref Drawing -B – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue and Red Yellow White Electrical characteristics 4.63 in (117.60 mm) 2.4 in (60.96 mm) Supply Current Frequency 0.57 lbs Dual Entry (SE/BE, BES, 3W) 12 ft 18 AWG 50 Hz /60 Hz Order information 10 Pack 80683 Pallet Pack DIY Pack IP Pack Order information 10 Pack 71443, 71444, 71445 Pallet Pack DIY Pack IP Pack Specifications by lamp and wattage Safety and performance UL Type 1 Outdoor UL Type HL System Ballast Factor 1.00 1.00 1.10 1.10 1.00 1.00 1.00 1.00 0.98 0.98 98.00 0.98 FCC – CLASS B Consumer Ballast Efficacy Factor 1.85 1.85 3.79 3.79 1.96 1.96 3.70 3.70 2.13 2.13 272.22 2.72 Power Factor % (>=) 99 99 98 98 99 99 98 98 98 98 98 98 FCC Part 18 Class B at 120 volts Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 UL Class P THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10 UL Type CC Min. Starting Temp (°F/°C) -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 UL Listed Safety and performance Nom. Line Current 0.63 A 0.26 A 0.34 A 0.15 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.90 0.90 1.00 1.00 Ballast Efficacy Factor 1.18 1.23 2.43 2.50 FCC – CLASS A Non-Consumer UL Listed Sign Ballasts 50 Hz/60 Hz Wiring diagram – CFL 5 – see example on page 132 Case dimensions – Ref Drawing 13 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge 4.3 in (107.95 mm) 3.0 in (75.69 mm) 1.0 in (25.40 mm) 4.9 in (125.47 mm) 4.6 in (117.09 mm) 1.6 in (39.37 mm) Electronic – Standard Instant Start Instant start Series 10% 105°F (41°C) 70 °C (158 °F) Normal Passive A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected Electrical characteristics Supply Current Frequency 0.90 lbs Bottom/Side 12 ft 18 AWG 50 Hz /60 Hz Order information 10 Pack 80680 Pallet Pack DIY Pack IP Pack Order information DIY Pack IP Pack Specifications by lamp and wattage Lamp FCC – CLASS A Non Consumer FCC Part 18 Class B at 120 volts Crest Factor (<=) 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 UL Class P THD (<=) 10 10 10 10 10 10 10 10 UL Type CC Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 0 / -18 UL Listed FT40W/4P # of Lamps 2 1 Line Volts 120 120 System Watts 67 40 Safety and performance Nom. Line Current 0.61 A 0.40 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.88 1.02 Ballast Efficacy Factor 1.31 2.55 FCC – CLASS A Non-Consumer UL Class P Power Factor % (>=) 95 90 CSA Crest Factor (<=) 1.7 1.7 THD (<=) 20 20 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 UL Listed CSA See page 195 for warranty information. See page 195 for warranty information. 125 HID Electromagnetic Ballasts # of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) 2 120 91 0.76 A 0.98 1.08 98 2 277 90 0.32 A 0.98 1.09 98 1 120 45 0.40 A 1.00 2.22 93 CFTR42W/4P 1 277 45 0.18 A 1.00 2.22 93 1 120 69 0.58 A 1.00 1.45 98 CFTR32W/4P 1 277 67 0.26 A 1.00 1.49 98 2 120 56 0.46 A 1.02 1.82 95 CFTR26W/4P 2 277 65 0.20 A 1.02 1.85 95 Other compatible lamps: FT55W/4P, FT36W/4P, FT24W/4P, FC9T522W/4P, FC12T555W/4P, FC12T540W/4P, CFTR70W/4P, CFTR57W/4P, CFS28W/4P, CFM3W/4P UL Type HL 9.5 in (241.30 mm) 8.8 in (225.80 mm) 1.6 in (42.87 mm) 0.3 in (7.92 mm) 2.70 lbs Side 12 ft 18 AWG Length (± 1 in) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm) 25 in (635 mm) Specifications by lamp and wattage Lamp UL Type 1 Outdoor 8.3 in (211.07 mm) 2.4 in (60.96 mm) 1.5 in (39.37 mm) HID Electronic Ballasts Wiring diagram – CFL 1B – see example on page 131 Case dimensions – Ref Drawing C6 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black Compact Fluorescent Ballasts Electrical characteristics 124 Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Dimensions Electronic – Program / Rapid start Programmed start Series 10% 122°F (50°C) 75°C (167°F) Normal Active A (20-24 decibels) Auto restart, Thermally protected, Universal voltage Safety and performance THD (<=) 10 10 10 10 • Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case General characteristics General characteristics Pallet Pack CSA Crest Factor (<=) 1.5 1.5 1.5 1.5 2 – FT40W/2G11 IS 120 2 – 42/36/32/26/24 watt CFL UNV Side Exit 10 Pack 47506, 47509 UL Class P Power Factor % (>=) 98 98 95 95 ProLine® CFL Electronic Ballasts ProLine CFL Electronic Ballasts Supply Current Frequency System Watts 76 73 41 40 80680 – C240SI120RH-IP ® Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Line Volts 120 277 120 277 CSA • Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case 47506 – C242UNVBES-IP 47509 – C242UNVSE-IP FT40W/4P # of Lamps 2 2 1 1 T12 Fluorescent Ballasts # of Lamps Line Volts System Watts Nom. Line Current 2 120 54 0.45 A 2 277 54 0.20 A 1 120 29 0.24 A CFTR26W/GX24q 1 277 29 0.11 A 1 120 51 0.43 A 1 277 51 0.19 A 2 120 27 0.23 A CFQ26W/G24q 2 277 27 0.10 A 1 120 46 0.38 A CFTR42W/GX24q 1 277 46 0.17 A 1 120 36 0.31 A CFTR32W/GX24q 1 277 36 0.13 A Other compatible lamps: F24T5/HO, CFS21W/GR10q, FT24W/2G11, FC16T9/40W 8.8 in (225.80 mm) 0.8 in (22.35 mm) 0.3 in (7.92 mm) 1.10 lbs Side 12 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 48 in (1219 mm) 25 in (635 mm) Specifications by lamp and wattage Lamp Lamp 9.5 in (241.30 mm) 1.5 in (38.10 mm) 1.0 in (25.40 mm) T5 Fluorescent Ballasts Electronic – Program / Rapid start Programmed start Series 10% 104°F (40°C) 75°C (167°F) Normal Active A (20-24 decibels) Auto restart, Thermally protected, Universal voltage Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 2 – CFQ26W, FT24 or 1 – 24W CFTR32 120-227V ProLine® PS Supply Current Frequency ProLine® CFL Electronic Ballasts 2 or 1 – FT40W2G11 PS UNV ® Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case 80683 – C240PUNVHP-B-IP T8 Fluorescent Ballasts • Multi-voltage technology means a single ballast handles voltage from 108V to 305V • Programmed starting for extended lamp life • End-of-Lamp-Life protection • Color coded poke-in connectors simplifies wiring 71443 – GEC226-MVPS-BES 71444 – GEC226-MVPS-SE 71445 – GEC226-MVPS-3W Quick Reference Guides gelighting.com ProLine® CFL Electronic Ballasts ProLine® CFL Electronic Ballasts For 40W Biax® CFL Ballasts For 40W Biax® CFL Ballasts • Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case 80681 – C240SI277RH-IP • Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case 80691 – C340SI277RH-IP ProLine® CFL Electronic Ballasts 2 – FT40W/2G11- IS 277 3 – FT40W/2G11 IS 277 General characteristics Dimensions Electrical characteristics Supply Current Frequency 50 Hz /60 Hz Order information 10 Pack 80681 Pallet Pack DIY Pack General characteristics Wiring diagram – CFL 1B – see example on page 131 Case dimensions – Ref Drawing C6 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black IP Pack 8.3 in (211.07 mm) 2.4 in (60.96 mm) 1.5 in (39.37 mm) 9.5 in (241.30 mm) 8.8 in (225.80 mm) 1.6 in (42.87 mm) 0.3 in (7.92 mm) 2.70 lbs Side 12 ft 18 AWG Length (± 1 in) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm) 25 in (635 mm) Line Volts 277 277 System Watts 67 40 Safety and performance Wiring diagram – CFL 51 – see example on page 131 Case dimensions – Ref Drawing C6 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black Electrical characteristics 50 Hz /60 Hz Order information 10 Pack 80691 Pallet Pack DIY Pack IP Pack 8.3 in (211.07 mm) 2.4 in (60.96 mm) 1.5 in (39.37 mm) 9.5 in (241.30 mm) 8.8 in (225.80 mm) 1.6 in (42.87 mm) 0.3 in (7.92 mm) 2.70 lbs Side 12 ft 18 AWG Length (± 1 in) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm) 25 in (635 mm) Specifications by lamp and wattage Nom. Line Current 0.27 A 0.17 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.88 1.02 Ballast Efficacy Factor 1.31 2.55 FCC – CLASS A Non-Consumer UL Class P Power Factor % (>=) 95 90 CSA Crest Factor (<=) 1.7 1.7 THD (<=) 20 20 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 Lamp FT40W/4P # of Lamps 3 2 Line Volts 277 277 System Watts 98 75 Safety and performance UL Listed Nom. Line Current 0.39 A 0.30 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.88 0.99 Ballast Efficacy Factor 0.89 1.32 FCC – CLASS A Non-Consumer UL Class P Power Factor % (>=) 95 90 CSA Crest Factor (<=) 1.7 1.7 THD (<=) 20 20 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 UL Listed Sign Ballasts • Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case 80690 – C340SI120RH-IP T12 Fluorescent Ballasts FT40W/4P # of Lamps 2 1 Electronic – Standard Instant Start Instant start Series 10% 105°F (41°C) 70 °C (158 °F) Normal Passive A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected Supply Current Frequency Specifications by lamp and wattage Lamp Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T5 Fluorescent Ballasts Electronic – Standard Instant Start Instant start Series 10% 105°F (41°C) 70 °C (158 °F) Normal Passive A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected T8 Fluorescent Ballasts ProLine® CFL Electronic Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Quick Reference Guides gelighting.com ProLine® CFL Electronic Ballasts 3 – FT40W/2G11 IS 120 General characteristics Dimensions Electronic – Standard Instant Start Instant start Series 10% 105°F (41°C) 70 °C (158 °F) Normal Passive A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected Electrical characteristics Supply Current Frequency 50 Hz /60 Hz Order information 10 Pack 80690 Pallet Pack DIY Pack IP Pack 8.3 in (211.07 mm) 2.4 in (60.96 mm) 1.5 in (39.37 mm) 9.5 in (241.30 mm) 8.8 in (225.80 mm) 1.6 in (42.87 mm) 0.3 in (7.92 mm) 2.70 lbs Side 12 ft 18 AWG Length (± 1 in) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm) 25 in (635 mm) HID Electronic Ballasts Wiring diagram – CFL 51 – see example on page 131 Case dimensions – Ref Drawing C6 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black Compact Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp FT40W/4P # of Lamps 3 2 Line Volts 120 120 Safety and performance Nom. Line Current 0.88 A 0.68 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.88 0.99 Ballast Efficacy Factor 0.89 1.32 FCC – CLASS A Non-Consumer UL Class P Power Factor % (>=) 95 90 CSA Crest Factor (<=) 1.7 1.7 THD (<=) 20 20 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 UL Listed See page 195 for warranty information. See page 195 for warranty information. 127 HID Electromagnetic Ballasts 126 System Watts 98 75 ProLine® CFL Electronic Ballasts CFL Magnetic Ballasts For 5 – 26W Preheat CFL Lamps For 5 – 26W Preheat CFL Lamps • Magnetic compact fluorescent ballast construction for all general fluorescent lighting 87634 – GEM1CF579PH277 2 – CFT/Q13W/GX23 Pre Heat 277 (4214PBES) General characteristics Dimensions Magnetic – Preheat Preheat Series 5% 105°F (41°C) 90°C (194°F) Normal Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 87634 Pallet Pack DIY Pack IP Pack 2.8125 (71.43 mm) 1.1875 (30.16 mm) 1.6 in (41.14 mm) 2.8 in (71.45 mm) 2.3 in (60.45 mm) 0.1 in (4.77 mm) 0.60 lbs Side 10 ft 18 AWG Length (± 1 in) 7 in (178 mm) 9 in (229 mm) Line Volts 277 277 277 277 277 277 System Watts 11 11 11 10 9 8 Safety and performance Electrical characteristics System Ballast Factor 0.90 0.85 1.00 1.00 0.95 0.95 UL Type HL UL Class P Order information 10 Pack 87655 Ballast Efficacy Factor 8.18 7.72 9.09 10.00 10.55 11.87 Power Factor % (>=) 25 27 50 22 45 40 Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 THD (<=) 15 15 15 15 15 15 Min. Starting Temp (°F/°C) 25 / -4 25 / -4 25 / -4 25 / -4 25 / -4 25 / -4 Dimensions A (20-24 decibels) Thermally protected 60 Hz Order information DIY Pack Safety and performance Nom. Line Current 0.12 A 0.12 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.90 0.90 UL Class P Ballast Efficacy Factor 2.81 2.81 Power Factor % (>=) 95 95 Crest Factor (<=) 1.7 1.7 THD (<=) 30 30 Min. Starting Temp (°F/°C) 25 / -4 25 / -4 UL Listed • Magnetic compact fluorescent ballast construction for all general fluorescent lighting 87700 – GEM2CF24PH277 IP Pack Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info 3.0 in (77.01 mm) 1.25 in (31.75 mm) 1.75 in (44.45 mm) 3.0 in (77.01 mm) 2.75 in (69.85 mm) 0.2 in (5.58 mm) 0.62 lbs Side 10 ft 18 AWG Length (± 1 in) 7 in (178 mm) 9 in (229 mm) Magnetic – Preheat Preheat Parallel 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 87700 Pallet Pack DIY Pack IP Pack Wiring diagram – CFL 8 – see example on page 131 Case dimensions – Ref Drawing 10 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Black White 6.5 in (166.62 mm) 2.3 in (60.45 mm) 1.6 in (42.92 mm) 6.5 in (166.62 mm) 6.0 in (152.40 mm) 0.3 in (7.87 mm) 2.93 lbs Bottom 10 ft 18 AWG Length (± 1 in) 15 in (381 mm) 15 in (381 mm) 15 in (381 mm) Specifications by lamp and wattage Nom. Line Current 0.25 A 0.25 A UL Class P System Ballast Factor 0.90 0.90 cUL Listed Ballast Efficacy Factor 6.00 6.00 Power Factor % (>=) 50 50 Crest Factor (<=) 1.7 1.7 THD (<=) 10 10 Min. Starting Temp (°F/°C) 50 / 10 50 / 10 Lamp CFQ26W/2P CFTR26W/2P # of Lamps 2 2 Line Volts 277 277 System Watts 55 55 Safety and performance UL Listed See page 195 for warranty information. See page 195 for warranty information. Nom. Line Current 0.25 A 0.25 A UL Type 1 Outdoor UL Type HL System Ballast Factor 0.90 0.90 UL Class P Ballast Efficacy Factor 1.63 1.63 Power Factor % (>=) 97 97 Crest Factor (<=) 1.5 1.5 THD (<=) 30 30 Min. Starting Temp (°F/°C) 25 / -4 25 / -4 UL Listed 129 HID Electromagnetic Ballasts 128 UL Type HL System Watts 32 32 HID Electronic Ballasts Safety and performance System Watts 15 15 Line Volts 277 277 General characteristics Wiring diagram – CFL 21 – see example on page 131 Case dimensions – Ref Drawing 2 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Black Specifications by lamp and wattage Line Volts 120 120 # of Lamps 2 2 Compact Fluorescent Ballasts Magnetic – Preheat Preheat Series 5% 105°F (41°C) 90°C (194°F) Normal Electrical characteristics # of Lamps 1 1 Lamp CFQ13W/2P CFT13W/2P 2 – CFQ26W/G24d Pre Heat 277 (4226PBES) General characteristics Lamp CFQ13W/2P CFT13W/2P IP Pack CFL Magnetic Ballasts 1 – CFT/Q13W/GX23 Pre Heat 120 (4111H2P) Pallet Pack DIY Pack 0.2 in (5.58 mm) 1.60 lbs Bottom 10 ft 18 AWG Length (± 1 in) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) Sign Ballasts ProLine® CFL Electronic Ballasts 10 Pack 87533 Pallet Pack 4.75 in (120.65 mm) 4.375 in (111.12 mm) UL Listed • Magnetic compact fluorescent ballast construction for all general fluorescent lighting 87533 – GEM1CF13PH120 Supply Current Frequency 60 Hz 4.75 in (120.65 mm) 2.1 in (55.62 mm) 1.6 in (41.40 mm) Specifications by lamp and wattage Nom. Line Current 0.16 A 0.15 A 0.14 A 0.18 A 0.15 A 0.16 A UL Type 1 Outdoor Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info A (20-24 decibels) Auto-restart, Thermally protected Wiring diagram – CFL 9 – see example on page 131 Case dimensions – Ref Drawing 8 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Black White T12 Fluorescent Ballasts # of Lamps 1 1 1 1 1 1 Magnetic – Preheat Preheat Series 5% 105°F (41°C) 90°C (194°F) Normal Supply Current Frequency Specifications by lamp and wattage Lamp CFT7W/2P CFT9W/2P F8T5 CFT5W/2P F6T5 F4T5 Dimensions Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info T5 Fluorescent Ballasts A (20-24 decibels) Auto-restart, Thermally protected General characteristics Wiring diagram – CFL 21 – see example on page 131 Case dimensions – Ref Drawing 01 – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Black T8 Fluorescent Ballasts CFL Magnetic Ballasts 1 – CFT579Q9W/G23 Pre Heat 277 (4205F2P) Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info • Magnetic compact fluorescent ballast construction for all general fluorescent lighting 87655 – GEM2CF13PH277 ProLine® CFL Electronic Ballasts Quick Reference Guides gelighting.com CFL Magnetic Ballasts Wiring Diagrams Compact Fluorescent Ballasts For 36 – 40W CFL Lamps • Magnetic compact fluorescent ballast construction for all general fluorescent lighting 87623 – GEM2FT36RS120 CFL 20C CFL 1B CFL 51 CFL 21 CFL 9 CFL 8 T8 Fluorescent Ballasts CFL Magnetic Ballasts 2 – FT36W/2G11 RS 120 (4150P) General characteristics Dimensions Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 87623 Pallet Pack DIY Pack IP Pack Wiring diagram – CFL 5 – see example on page 132 Case dimensions – Ref Drawing ST – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 3.38 lbs Side 10 ft 18 AWG Length (± 1 in) 20 in (508 mm) 20 in (508 mm) 20 in (508 mm) T5 Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info Specifications by lamp and wattage Lamp FT36W/4P # of Lamps 2 Line Volts 120 System Watts 78 UL Type 1 Outdoor UL Type HL System Ballast Factor 0.96 UL Class P Ballast Efficacy Factor 1.23 Power Factor % (>=) 93 Crest Factor (<=) 1.7 THD (<=) 20 Min. Starting Temp (°F/°C) 50 / 10 UL Listed T12 Fluorescent Ballasts Safety and performance Nom. Line Current 0.70 A Sign Ballasts • Magnetic compact fluorescent ballast construction for all general fluorescent lighting 87625 – GEM2FT40RS120 Quick Reference Guides gelighting.com CFL Magnetic Ballasts 2 – FT40W/2G11RS RS 120 (4152P) General characteristics Dimensions Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected Electrical characteristics Supply Current Frequency 60 Hz Order information 10 Pack 87625 Pallet Pack DIY Pack IP Pack Wiring diagram – CFL 5 – see example on page 132 Case dimensions – Ref Drawing ST – see page 133 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow 9.5 in (241.30 mm) 2.3 in (60.45 mm) 1.5 in (39.37 mm) 8.8 in (225.80 mm) 1.6 in (42.92 mm) 0.3 in (7.92 mm) 3.38 lbs Side 10 ft 18 AWG Length (± 1 in) 20 in (508 mm) 20 in (508 mm) 20 in (508 mm) Compact Fluorescent Ballasts Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info HID Electronic Ballasts Specifications by lamp and wattage Lamp FT40W/4P # of Lamps 2 Line Volts 120 Safety and performance Nom. Line Current 0.68 A UL Type 1 Outdoor UL Type HL System Ballast Factor 1.00 UL Class P Ballast Efficacy Factor 1.23 Power Factor % (>=) 98 Crest Factor (<=) 1.7 THD (<=) 20 Min. Starting Temp (°F/°C) 50 / 10 UL Listed See page 195 for warranty information. See page 195 for warranty information. 131 HID Electromagnetic Ballasts 130 System Watts 81 Case Dimensions Compact Fluorescent Ballasts CFL 5 -B 8 01 10 T8 Fluorescent Ballasts Wiring Diagrams Compact Fluorescent Ballasts Quick Reference Guides gelighting.com T5 Fluorescent Ballasts T12 Fluorescent Ballasts 2 Sign Ballasts CFL 1-2 13 Compact Fluorescent Ballasts See page 195 for warranty information. See page 195 for warranty information. ST 133 HID Electromagnetic Ballasts 132 HID Electronic Ballasts C6 Electronic HID For 20 – 150W Pulse Start HID Lamps Electronic HID T8 Fluorescent Ballasts • Light weight, low-profile housing • Superior low-frequency square-wave-frequency design maximizes performance and life of ceramic metal halide lamps • Ultra-slim can size for fixture design flexibility 87490 – GEMH20-MLF-120 1 – 20W M156 120V Electronic HID General characteristics ® GE’s line of UltraCool UltraMax eHID ballasts can provide up to 70% energy savings and four times the life of standard halogen. End users can meet strict watts per square foot requirements while achieving significant wattage savings and color control with ceramic metal halide lamps and GE eHID ballasts. 133 Hz 60 Hz/ 50 Hz/ Supply Current Frequency (MIN) / 50 Hz Order information Type Case No. Items Per Sales Unit 1 No. Items Per Standard Package 12 Specifications by lamp and line voltage Lamp M156 20W Ceramic Metal Halide Specifications by line voltage 120 22.50 0.36 A 1 0.89 4,000V 96V 56 1.40 79 0 / -18 3 System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance RoHS Compliant ANSI – C62.41 UL 1029 Listed FCC-CLASS A Non-Consumer Electronic HID 1 – 39W M130 120V Electronic HID General characteristics Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Ambient Temperature (MAX) Case Temperature (MAX) Sound Rating Additional Info Electronic – Low Frequency M130 120 10% Wiring diagram WD-eHID MLF/MSF – see example on page 140 Case dimensions – Ref Drawing MSF – see page 141 Length (L) 3.7 in (94.99 mm) Width (W) 2.9 in (75.69 mm) Height (H) 1.2 in (30.73 mm) Frame Size (H x L) Mounting dimensions Bracket Length (BL) Mount Length (M) 3.3 in (86.10 mm) Mount Width (X or F) 2.5 in (63.75 mm) Mount Slots (MS) 0.1 in (4.31 mm) Weight 0.38 lbs Exit Type Side Remote Mounting Distance to Lamp 8 ft Remote Mounting Wire Gauge 18 AWG Lead lengths Black Brown White Red 131°F (55°C) 90 °C (194 °F) A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected Electrical characteristics 130 Hz Lamp Watts Voltage 120 = 120 volt 277 = 277 volt 347 = 347 volt 480 = 480 volt MV = 120-277 volts Pack Type No extension = Standard Distributor Pack B=Bulk pack Specifications by line voltage Safety and performance See page 195 for warranty information. 120 43.00 0.37 A 1.00 0.91 System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 96V 99 1.40 6.80 0 / -18 3 RoHS Compliant See page 195 for warranty information. UL Type 1 Outdoor ANSI – C62.41 Suitable for recessed use UL 1029 Listed cUL Listed UL Listed 135 HID Electromagnetic Ballasts 134 Connector F = Side leads w/ feet N = Side leads no feet J = Bottom leads w/ studs JN = Bottom leads no studs No. Items Per Standard Package 10 Specifications by lamp and line voltage Lamp M130 39W Ceramic Metal Halide G E M H 1 0 0 M S F - 1 2 0 Housing MA=Metal Housing ML=Mini Slim MS=Mini Square SL=Slim Line E=PCB board No. Items Per Sales Unit 1 HID Electronic Ballasts Order information Type Case GE Ballast GEMH = Electronic MH UL Listed 87501 – GEMH39-MSF-120 Lamp Operating Frequency GE Ballast HID Electronic nomenclature cUL Listed Compact Fluorescent Ballasts GE high-wattage eHID ballasts will operate 250, 300, 320,350 or 400 watt pulse start or ceramic metal halide lamps with one ballast. The eHID Ballast with a PulseArc lamp will produce 70% more lumens per watt than the obsolete probe start magnetic core and coil system. Variable dimming to 50% power reduction is an option with GE eHID high wattage ballast. Electrical characteristics Lamp Operating Frequency Supply Current Frequency Sign Ballasts GE’s UltraMax® eHID ballasts operate only pulse start and ceramic metal halide lamps. GE UltraMax® eHID ballasts operate lamps at a low frequency square wave to maximize lamp performance. Extensive analysis of all brands of lamps suggests that the most compatible driving waveform for an electronic HID electronic ballast is a low-frequency squared wave (L.F.S.W.) with higher order harmonic content. L.F.S.W. has been established as a dependable method of ballasting low-wattage HID lamps with significant industry support. Analysis of lamp data has shown that there are limited operating bands between 1 kHz to 200 kHz in which electronic ballast could operate a lamp wattage family without causing unacceptable arc instability due to acoustic resonance. GE’s UltraMax® eHID constantly measures and adjusts the wattage, optimizing the ceramic metal halide lamp performance. 131°F (55°C) 85°C (185°F) A (20-24 decibels) End-of-Life Protection (EOL), Inherent thermal protection Wiring diagram WD-eHID MLF/MSF – see example on page 140 Case dimensions – Ref Drawing MLF – see page 141 Length (L) 3.7 in (94.99 mm) Width (W) 1.5 in (39.87 mm) Height (H) 1.0 in (25.40 mm) Frame Size (H x L) Mounting dimensions Bracket Length (BL) Mount Length (M) 3.3 in (85.34 mm) Mount Width (X or F) 1.1 in (30.22 mm) Mount Slots (MS) 0.1 in (4.31 mm) Weight 0.38 lbs Exit Type Side Remote Mounting Distance to Lamp 8 ft Remote Mounting Wire Gauge 18 AWG Lead lengths Black Brown White Red T12 Fluorescent Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly improve the performance of HID lighting. Electronic UltraMax® eHID Ballasts use solid-state components to start and operate HID lamps. Electronic eHID ballasts use IC chips to control and give feedback for optimal performance of the lighting system. GE eHID ballasts improve the efficiency, maintain higher lumens, enhance lamp life and color control, and operate more quietly than the magnetic core and coil ballast that they replace. Electronic – Low Frequency M156 120 10% Electronic T5 Fluorescent Ballasts Understanding Electronic UltraMax® HID Ballasts ™ Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Ambient Temperature (MAX) Case Temperature (MAX) Sound Rating Additional Info Quick Reference Guides gelighting.com Electronic HID For 20 – 150W Pulse Start HID Lamps For 20 – 150W Pulse Start HID Lamps 87516 – GEMH50-MSF-120 87546 – GEMH70-SLJ-MV Electronic HID Electronic HID 1 – 70W, M98, M/C143, 120V. Electronic HID 1 – 50W, M110, M/C148, 120V. Electronic HID General characteristics Electronic – Low Frequency M148, M110, C148 120 10% Electronic Electrical characteristics 130 Hz 60 Hz/50 Hz Order information No. Items Per Sales Unit 1 Length (± 1 in) 10 in (254 mm) 10 in (254 mm) 10 in (254 mm) 10 in (254 mm) No. Items Per Standard Package 10 120 58 0.48 A 1 System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance 131°F (55°C) 90°C (194°F) A (20-24 decibels) End of Life Protection (EOL), Thermally protected Electrical characteristics Lamp Operating Frequency 130 Hz Order information No. Items Per Sales Unit 1 96V 99 1.4 6.9 0 / -18 130 Lamp M98, M143, M139, C143, C139 70W Ceramic Metal Halide Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 120 58 0.48 A 1 0.86 70W Quartz Metal Halide 96V 99 1.4 6.9 0 / -18 130 Pulse Arc RoHS Compliant UL Type 1 Outdoor ANSI – C62.41 UL 1029 Listed FCC-CLASS A Non-Consumer cUL Listed 277 77 0.30 A 1 0.91 96V 99 1.4 4.9 0 / -18 3 96V 97 1.4 7.7 0 / -18 3 RoHS Compliant Electronic HID 1 – 70W, M98, M/C143, 120V Electronic HID Dimensions General characteristics Length (± 1 in) 10 in (254 mm) 10 in (254 mm) 10 in (254 mm) 10 in (254 mm) cUL Listed 131°F (55°C) 90°C (194°F) A (20-24 decibels) End of Life Protection (EOL), Thermally protected 130 Hz Length (± 1 in) 10 in (254 mm) 10 in (254 mm) 10 in (254 mm) 10 in (254 mm) No. Items Per Standard Package 10 Electronic – Low Frequency M90, M140, C140 120/277 10% 131°F (55°C) 90°C (194°F) A (20-24 decibels) End of Life Protection (EOL), Thermally protected Electrical characteristics Lamp Operating Frequency 130 Hz Order information Type Case No. Items Per Sales Unit 1 No. Items Per Standard Package 10 Specifications by lamp and line voltage Lamp M90, M140 100W Ceramic Metal Halide Specifications by line voltage 120 77 0.68 A 1.00 0.91 RoHS Compliant UL Type 1 Outdoor ANSI – C62.41 UL 1029 Listed FCC-CLASS A Non-Consumer cUL Listed UL Listed See page 195 for warranty information. Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance 120 110 0.93 A 1 0.91 277 107 0.41 A 1 0.93 96V 99 1.4 4.7 0 / -18 3 96V 98 1.4 7.8 0 / -18 3 RoHS Compliant See page 195 for warranty information. UL Type 1 Outdoor Lamp C140 Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise ANSI – C62.41 UL 1029 Listed 120 110 0.93 A 1 277 107 0.41 A 1 96V 99 1.4 4.7 0 / -18 3 96V 98 1.4 7.8 0 / -18 3 cUL Listed 137 HID Electromagnetic Ballasts 100W Quartz Metal Halide 99 1.4 8.3 0 / -18 3 Housing meets UL94V0 flame retardant Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Ambient Temperature (MAX) Case Temperature (MAX) Sound Rating Additional Info Specifications by lamp and line voltage Safety and performance Wiring diagram WD - eHID SLJ – see example on page 140 Case dimensions – Ref Drawing SLJ – see page 141 Length (L) 7.2 in (184.91 mm) Width (W) 2.5 in (65.53 mm) Height (H) 2.2 in (55.88 mm) Frame Size (H x L) Mounting dimensions Bracket Length (BL) Mount Length (M) 0.4 in (10.92 mm) Mount Width (X or F) Mount Slots (MS) Weight 0.38 lbs Exit Type Bottom Leads with Studs Remote Mounting Distance to Lamp 8 ft Remote Mounting Wire Gauge 18 AWG Lead lengths Qty Exit Black 1 Left Brown 1 Right White 1 Left Red 1 Right FCC-CLASS A Non-Consumer HID Electronic Ballasts Wiring diagram WD-eHID MLF/MSF – see example on page 140 Case dimensions – Ref Drawing MSF – see page 141 Length (L) 3.7 in (94.99 mm) Width (W) 2.9 in (75.69 mm) Height (H) 1.2 in (30.73 mm) Frame Size (H x L) Mounting dimensions Bracket Length (BL) Mount Length (M) 3.3 in (86.10 mm) Mount Width (X or F) 2.5 in (63.75 mm) Mount Slots (MS) 0.1 in (4.31 mm) Weight 0.38 lbs Exit Type Side Remote Mounting Distance to Lamp 8 ft Remote Mounting Wire Gauge 18 AWG Lead lengths Qty Exit Black 1 Left Brown 1 Right White 1 Left Red 1 Right Order information 136 UL 1029 Listed Compact Fluorescent Ballasts Electronic – Low Frequency M98, M143, M139, C143, C139 120 10% Electrical characteristics 70W Quartz Metal Halide ANSI – C62.41 1 – 100W, M90, M/C140, 120V-277V Electronic HID General characteristics System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise UL Type 1 Outdoor Sign Ballasts Electronic HID Lamp M98, M143, M139 , C143, C139 70W Ceramic Metal Halide Length (± 1 in) 10 in (254 mm) 10 in (254 mm) 10 in (254 mm) 10 in (254 mm) UL Listed 87561 – GEMH100-SLJ-MV No. Items Per Sales Unit 1 0.38 lbs Bottom Leads with Studs 8 ft 18 AWG Qty Exit 1 Left 1 Right 1 Left 1 Right No. Items Per Standard Package 10 120 77 0.66 A 1 0.91 87531 – GEMH70-MSF-120 Type Case 0.4 in (10.92 mm) Specifications by Line Voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance Lamp Operating Frequency 7.2 in (184.91 mm) 2.5 in (65.53 mm) 2.2 in (55.88 mm) Specifications by lamp and line voltage Lamp M110 50W Quartz Metal Halide Housing meets UL94V0 flame retardant Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Ambient Temperature (MAX) Case Temperature (MAX) Sound Rating Additional Info Wiring diagram WD-eHID SLJ – see example on page 140 Case dimensions – Ref Drawing SLJ – see page 141 Length (L) Width (W) Height (H) Frame Size (H x L) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Brown White Red T12 Fluorescent Ballasts Specifications by line voltage Electronic – Low Frequency M98, M143, C143, M139, C139 120/277 10% Type Case Specifications by lamp and line voltage Lamp M148 C148 Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Ambient Temperature (MAX) Case Temperature (MAX) Sound Rating Additional Info T5 Fluorescent Ballasts Wiring diagram WD-eHID MLF/MSF – see example on page 140 Case dimensions – Ref Drawing MSF – see page 141 Length (L) 3.7 in (94.99 mm) Width (W) 2.9 in (75.69 mm) Height (H) 1.2 in (30.73 mm) Frame Size (H x L) Mounting dimensions Bracket Length (BL) Mount Length (M) 3.3 in (86.10 mm) Mount Width (X or F) 2.5 in (63.75 mm) Mount Slots (MS) 0.1 in (4.31 mm) Weight 0.62 lbs Exit Type Side Remote Mounting Distance to Lamp 8 ft Remote Mounting Wire Gauge 18 AWG Lead lengths Qty Exit Black 1 Left Brown 1 Right White 1 Left Red 1 Right 131°F (55°C) 90°C (194°F) A (20-24 decibels) End of Life Protection (EOL), Thermally protected Lamp Operating Frequency Supply Current Frequency Type Case General characteristics Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Ambient Temperature (MAX) Case Temperature (MAX) Sound Rating Additional Info T8 Fluorescent Ballasts Electronic HID Quick Reference Guides gelighting.com Electronic HID For 20 – 150W Pulse Start HID Lamps For 250 – 400W Pulse Start HID Lamps 87576 – GEMH150-SLJ-MV 29377 – GE-MH-250-400-MA Electronic HID Electronic HID 1 – 150W, M102, M/C142, 120V-277V Electronic HID 1 – 250 to 400W, UltraMax® HID, Electronic, 208-277, 50-60 Hz General characteristics Dimensions Electronic – Low Frequency M142, M102, C142 120/277 10% 131°F (55°C) 85°C (185°F) A (20-24 decibels) End of Life Protection (EOL), Thermally protected Electrical characteristics Lamp Operating Frequency 130 Hz Order information Type Case No. Items Per Sales Unit 1 General characteristics Wiring diagram WD-eHID SLJ – see example on page 140 Case dimensions – Ref Drawing SLJ – see page 141 Length (L) Width (W) Height (H) Frame Size (H x L) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Brown White Red 7.2 in (184.91 mm) 2.5 in (65.53 mm) 2.2 in (55.88 mm) 0.4 in (10.92 mm) 0.38 lbs Bottom Leads with Studs 8 ft 18 AWG Qty Exit 1 Left 1 Right 1 Left 1 Right Length (± 1 in) 10 in (254 mm) 10 in (254 mm) 10 in (254 mm) 10 in (254 mm) No. Items Per Standard Package 10 Safety and performance 120 167 1.44 A 1 0.90 277 164 0.62 A 1 0.91 96V 99 1.4 4.2 0 / -18 3 96V 99 1.4 10.6 0 / -18 3 RoHS Compliant 130°F (54°C) A (20-24 decibels) Thermally protected Electrical characteristics Supply Current Frequency 50 Hz/ 60 Hz Order information No. Items Per Sales Unit 1 Length (± 1 in) 9 in (229 mm) 10 in (254 mm) 9 in (229 mm) 9 in (229 mm) No. Items Per Standard Package 1 UL Type 1 Outdoor Lamp C142 Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise ANSI – C62.41 UL 1029 Listed 120 167 1.44 A 1 277 164 0.62 A 1 96V 99 1.4 4.2 0 / -18 3 96V 99 1.4 10.6 0 / -18 3 FCC-CLASS A Non-Consumer Lamp M155, M135 400W Quartz Metal Halide Lamp 208 240 277 M154, M132 System Wattage (W) 431 431 428 320W Quartz Nominal Current 2.23 A 1.92 A 1.65 A Metal Halide Ballast Factor 1 1 1 Ballast Efficiency Factor 0.93 0.93 0.93 Open Circuit Voltage Drop Out Voltage Power Factor (>=)% 99 99 99 Crest Factor (<) THD % (<) 15 15 15 Min. Starting Temp (°F/°C) -20 / -29 -20 / -29 -20 / -29 Fuse Rating UL Bench Top Rise *Specifications by lamp and line voltage limited to two charts, please see gelighting.com for additional lamps. cUL Listed Specifications by line voltage Safety and performance UL Type 1 Outdoor UL Type HL UL Class P T12 Fluorescent Ballasts 150W Ceramic Metal Halide Wiring diagram eHID – see example on page 140 Case dimensions – Ref Drawing eHID - Bracket – see page 141 Length (L) 14.9 in (378.66 mm) Width (W) 14.9 in (378.66 mm) Height (H) 9.3 in (237.79 mm) Frame Size (H x L) Mounting dimensions Bracket Length (BL) 6.5 in (165.10 mm) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight 10.20 lbs Exit Type Bottom Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Qty Exit Black and Green 1 Bottom Brown and Red 1 Bottom White 1 Bottom Yellow 2 Bottom Specifications by lamp and line voltage Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Electronic – Dimming M155, M153, M138, M135, M132, M131, M154 208/240/277 10% Electronic Type Standard Pack Specifications by lamp and line voltage Lamp M102, M142 150W Quartz Metal Halide, Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Ambient Temperature (MAX) Case Temperature (MAX) Sound Rating Additional Info T5 Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Ambient Temperature (MAX) Case Temperature (MAX) Sound Rating Additional Info • High efficiency electronic ballast provides 48% less ballast losses compared to electromagnetic CWA ballasts • Improves lumen maintenance by 10 points on pulse start lamps • Multi-voltage technology handles voltage from 208 to 277V T8 Fluorescent Ballasts Electronic HID Quick Reference Guides gelighting.com Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise FCC-CLASS A Non-Consumer cUL Listed 208 346 1.79 A 1 0.92 240 346 1.54 A 1 0.92 277 343 1.34 A 1 0.93 99 99 99 15 -20 / -29 15 -20 / -29 15 -20 / -29 UL Listed Sign Ballasts 89646 – GEMH250-400M-V50 Electronic HID 1 – 250 to 400W, UltraMax® HID, Dimming, 208-277, 50-60Hz General characteristics Dimensions Electronic – Dimming M155, M153, M138, M135, M132, M131 208/240/277 10% Electronic 130°F (54°C) A (20-24 decibels) Thermally protected Electrical characteristics Supply Current Frequency 50 Hz/ 60 Hz Order information Type Standard Pack No. Items Per Sales Unit 1 14.9 in (378.66 mm) 14.9 in (378.66 mm) 9.3 in (237.79 mm) 6.5 in (165.10 mm) 10.20 lbs Bottom Qty 1 1 1 2 Exit Bottom Bottom Bottom Bottom Length (± 1 in) 9 in (229 mm) 10 in (254 mm) 9 in (229 mm) 9 in (229 mm) HID Electronic Ballasts Wiring diagram eHID– see example on page 140 Case dimensions – Ref Drawing eHID-DIM – see page 141 Length (L) Width (W) Height (H) Frame Size (H x L) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black and Green Brown and Red White Yellow Compact Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Ambient Temperature (MAX) Case Temperature (MAX) Sound Rating Additional Info No. Items Per Standard Package 1 Specifications by lamp & line voltage Lamp M155, M135 400W Quartz Metal Halide Specifications by line voltage Safety and performance 138 See page 195 for warranty information. See page 195 for warranty information. UL Type 1 Outdoor UL 1029 Listed UL Type HL Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Crest Factor (<) THD % (<) Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Housing meets UL94V0 flame retardant FCC-CLASS A Non-Consumer cUL Listed ANSI – C62.41 RoHS Compliant 208 346 1.79 A 1 0.92 240 346 1.54 A 1 0.92 277 343 1.34 A 1 0.93 99 99 99 15 -20 / -29 15 -20 / -29 15 -20 / -29 UL Listed 139 HID Electromagnetic Ballasts Lamp 208 240 277 M154, M132 System Wattage (W) 431 431 428 320W Quartz Nominal Current 2.23 A 1.92 A 1.65 A Metal Halide Ballast Factor 1 1 1 Ballast Efficiency Factor 0.93 0.93 0.93 Open Circuit Voltage Drop Out Voltage Power Factor (>=)% 99 99 99 Crest Factor (<) THD % (<) 15 15 15 Min. Starting Temp (°F/°C) -20 / -29 -20 / -29 -20 / -29 Fuse Rating UL Bench Top Rise *Specifications by lamp and line voltage limited to two charts, please see gelighting.com for additional lamps. Wiring Diagrams HID Electronic WD-eHID MLF/MSF WD-eHID-SLJ MLF MSF SLJ eHID-Bracket T8 Fluorescent Ballasts MLF MSF Case Dimensions HID Electronic Quick Reference Guides gelighting.com SLJ T5 Fluorescent Ballasts eHID T12 Fluorescent Ballasts Sign Ballasts Compact Fluorescent Ballasts eHID-DIM HID Electronic Ballasts See page 195 for warranty information. See page 195 for warranty information. 141 HID Electromagnetic Ballasts 140 Warm-Up Time 5-7 minutes 3-4 minutes 2 minutes 7-10 minutes Restrike Time 3-6 minutes 10-20 minutes 3-4 minutes 1/2-1 minute GE Oil-filled Capacitors are packaged in metal cases (up to 520V ratings). All GE capacitors are designed for 60,000 hours of continuous life. UL Bench Top Letter Code A B C D E F Temperature Range for Class H (180C) Ballast Less than 75C 75C < 80C 80C < 85C 85C < 90C 90C < 95C 95C < 100C Dry Capacitors do not contain oil and are manufactured with plastic casing. Dry casings are rated up 100°C maximum. Dry capacitors are designed and rated for AC voltages below 400V at 50 or 60Hz. GE HID Ballast Types GE HID ballast 150 watts or less have High Reactance Autotransformer circuits and high power factor (HX-HPF). GE HID ballast greater that 150 watts have Constant Wattage Autotransformer circuits and are high power factor (HPF). Potted Core and Coil Ballast GE potted core and coil ballasts are designed for applications requiring quieter or cooler operation than provided by standard coil and coil ballast. The potting material is sand-filled polyester which provides excellent sound-deadening and heat-transfer qualities. See page 195 for warranty information. G E M 1 0 0 0 M L T A C 5 D - 5 GE Ballast M = EM Ballast GEH = Mercury GEM = Metal Halide GEP = Pulse Start Metal Halide GES = HPS Lamp Watts: 1000W Voltage: MLT = Quad ML5 = Multi 5 T = Trivolt 48T = 480/120 tap 277 = 277V 230 = 230V Circuit Type: R = Reactor A = CWA I = CWI O = Iso Reg L = High Reactance/lag M = Mag Lag Type: C = Core & Coil Cu A = Core & Coil Aluminum F = F Can W = Weatherproof E = Encased/Potted I = Indoor Encased Frame Size: E=E&I 3 = 3x4 4 = 4-3/4 5 = 5-3/4 X = non C & C Capacitor: D = Dry Film O = Oil Film Pack Type: -5 = Dist. Kit -55 = Dist. Kit & Lamp -1 = C & C -1B = C & C w/welded bracket -60 = C & C no capacitor -61 = C & C w/ welded bracket, no cap 143 HID Electromagnetic Ballasts See page 195 for warranty information. Standard ignitors are supplied with metal halide ballast 150 watts or less, pulse start metal halide and high-pressure sodium ballast. There are several different ignitors that meet the needs of many GE lamp and ballast combinations. The appropriate ignitor is listed in the catalog under the ballast specifications. GE Ballast HID Electromagnetic nomenclature HID Electronic Ballasts CWA ballast is the most common circuit for core and coil ballast. CWA circuits provide for stable light regulation. The CWA circuit consists of a high reactance autotransformer with a capacitor in series with the lamp resulting with high power factor ballast. In most CWA ballast circuits a 10% drop in line voltage will only reduce the light output and wattage by 5%. The CWA circuit ballast requires an igniter for QMH pulse start, ceramic metal halide and HPS lamps. Igniters are also required for QMH lamps 150 watts or less. Ignitors Ignitors are also sold in individual cartons for replacement needs. Ignitors supply a high voltage pulse to ionize the gas creating the glow discharge. Once the lamp is started the ignitor stops providing the pulse. Ignitors are designed to last thousand of hours; however, if the lamp fails or the socket is empty, the ignitor will continue to pulse. The lamps should be replaced or the fixture turned off to prevent premature failure of the ignitor. Compact Fluorescent Ballasts CORE AND COIL The most common HID ballasts are the core and coil and is used in 90% of the fixture applications. Core and coil ballasts consist of one, two or three copper (or aluminum) coils on a core of electrical-grade steel laminations. HID ballasts are classified by the kind of circuit they use: Reactor (R), High Reactance autotransformer (HX), Constant Wattage Autotransformer (CWA), Regulated lag (Reg Lag) or Electronic. HID ballast are also classified as high power factor (HPF) or normal power factor (NPF). 142 Power factor capacitors are used to reduce the negative effects that inductive devices (HID ballast) have on power factor ratings. GE sells a complete line of capacitors that must be properly matched to the lamp and HID ballast. GE capacitors have bleed-in resistors and use biodegradable, nontoxic (no PCBs) dielectric fluid. UL Bench Top Temperature Code To help with UL inspection, the UL Bench top code is listed on the GE label on the core and coil ballast as 1029X. X is the temperature code and represented by the following temperature classifications: A, B, C, D, E and F. Sign Ballasts Light Source Mercury Metal Halide (Probe Start) Metal Halide (Pulse Start) High Pressure Sodium Capacitors Most GE capacitors and ignitors are sold in ballast kits that come pre-wired and reduce labor cost. Capacitors and ignitors are also sold separately. Date Codes GE HID core and coil ballast manufacturing date codes are located on the top end of the core. They are printed in white and indicate year, month manufactured, and order the ballast was manufactured in the month. A code of 070100001 would indicate manufacture date of 07 (year 2007), 01 (month of January), and 00001 would be the manufacturing sequence. T12 Fluorescent Ballasts HID lamps take several minutes to warm-up and reach full light output. If power is interrupted between the lamp and the ballast, the arc will extinguish and lamp will go out. The lamp must cool down and reduce the vapor pressure before it will re-start. Typical warm-up and restrike times are as follows: Ignitors and capacitors, where required, are included with the quad and 5-tap ballast kits. Ballast Date and Temperature Codes T5 Fluorescent Ballasts GE offers High Intensity Discharge (HID) ballasts for mercury, probe start metal halide, pulse start metal halide and high pressure sodium lamps. Standard metal halide lamps or probe start metal halide over 150 watts, like fluorescent, are electric discharge lamps and require an open circuit voltage of nearly two times the operating voltage to the initiate the arc between the two electrodes in the arc tube. High pressure sodium, pulse start metal halide and probe start metal halide lamps 150 watts or less require an ignitor to initiate the high voltage to start the lamps. The ballasts provide the starting voltage with the igniter, where required, and provides stability for the lamp. HID lamps have negative impedance characteristics and would draw current until destruction unless a ballast was in place to regulate the current. Also available for metal halide and high pressure sodium applications is the 5-tap ballast-lamp replacement kit listed as -55. This easy-tocarry, convenient, all-in-one kit, ensures ballast-lamp compatibility by including the lamp as well. F-Can Ballast GE F-Can ballast is recommended for indoor applications and where ballast noise must be minimized. F-Can ballast are encased in fluorescent ballast-type cans and potted with asphalt insulating materials to minimize noise. T8 Fluorescent Ballasts Understanding Electromagnetic HID Ballasts Distributor Ballast Kits GE stocks a comprehensive inventory of quad and 5-tap HID voltage ballast kits. The kits contain the appropriate core and coil, capacitor, ignitor (where required), mounting bracket, mounting hardware and instructions to allow the stocking distributor to meet the needs of their customer while minimizing their investment in component parts. The quad ballast kit has color-coded leads to identify voltages and operates at 120/208/240/277. The 5-tap HID ballast kits also include 480-volt applications and are listed as ML5, though GE also offers single-voltage kits for 480-volt with 120-volt taps for stand-by lighting. Quick Reference Guides gelighting.com Metal Halide Metal Halide For 20 – 175W Metal Halide HID Lamps For 20 – 175W Metal Halide HID Lamps Metal Halide 1 – 50W MH M110 or M148 Quad (120/208/240/277V) General characteristics Dimensions Magnetic – Core and Coil M110 or M148 120/208/240/277 5% HX-HPF 180C Dry film 6 Mfd 280 100°C (212°F) MH350-1A No. Items Per Standard Package 6 cUL Listed 208 61 0.30 A 1 0.82 0.67 A 0.34 A 264V 166V 90 -22 / -30 3 C 240 61 0.30 A 1 0.82 0.58 A 0.30 A 264V 192V 90 -22 / -30 2 C Lamp M98 70W Ceramic Metal Halide 277 61 0.20 A 1 0.82 0.50 A 0.26 A 264V 222V 90 -22 / -30 2 C 70W Quartz Metal Halide Dimensions UL Listed • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 86675 – GEM100MLTLC3D-5 Metal Halide 1 – 100W MH M90 or M140 Quad (120/208/240/277V) Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil M92, M90, M140 120/208/240/277 5% HX-HPF 180C Dry film 12 Mfd 280 100°C (212°F) Supply Current Frequency Wiring diagram HID W-(H)-86675-86718 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 3.0 Weight 5.00 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in 60 Hz Order information Type Distributor Kit 240 88 0.40 A 1 0.80 0.75 A 0.49 A 257V 192V 90 -22 / -30 3 A 277 88 0.40 A 1 0.80 0.66 A 0.44 A 257V 222V 90 -22 / -30 2 A Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=) % Min. Starting Temp Fuse Rating UL Bench Top Rise Safety and performance UL Listed See page 195 for warranty information. 120 119 1.10 A 1 208 119 0.60 A 1 240 119 0.50 A 1 277 119 0.50 A 1 2.27 A 1.26 A 274V 96V 90 -22 / -30 5 D 1.30 A 0.69 A 274V 166V 90 -22 / -30 4 D 1.13 A 0.60 A 274V 192V 90 -22 / -30 3 D 0.98 A 0.53 A 274V 222V 90 -22 / -30 3 D cUL Listed See page 195 for warranty information. Lamp M90, M140 100W Ceramic Metal Halide Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor 100W Max Input Current Quartz Starting Current Metal Halide Open Circuit Voltage Drop Out Voltage Power factor (>=) % Min. starting temperature Fuse rating UL bench top rise 120 119 1.10 A 1 0.84 2.27 A 1.26 A 274V 96V -22 / -30 5 D 208 119 0.60 A 1 0.84 1.30 A 0.69 A 274V 166V 90 -22 / -30 4 D 240 119 0.50 A 1 0.84 1.13 A 0.60 A 274V 192V 90 -22 / -30 3 D 277 119 0.50 A 1 0.84 0.98 A 0.53 A 274V 222V 90 -22 / -30 3 D UL Listed 145 HID Electromagnetic Ballasts cUL Listed 208 88 0.50 A 1 0.80 0.88 A 0.59 A 257V 166V 90 -22 / -30 3 A No. Items Per Standard Package 6 Specifications by lamp and line voltage Lamp M92 Specifications by line voltage 120 88 0.90 A 1 0.80 1.51 A 0.96 A 257V 96V 90 -22 / -30 4 A No. Items Per Sales Unit 1 HID Electronic Ballasts No. Items Per Standard Package 6 Specifications by lamp and line voltage 144 cUL Listed Electrical characteristics 60 Hz No. Items Per Sales Unit 1 Safety and performance 480 89 0.20 A 1 0.79 0.44 A 0.16 A 253V 384V 90 -22 / -30 1 C System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=) % Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise General characteristics Wiring diagram HID W-(H)-86824-86847 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 3.0 Weight 5.00 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Order information 70W Quartz Metal Halide Specifications by line voltage Compact Fluorescent Ballasts Magnetic – Core and Coil M98 or M143 120/208/240/277 5% HX-HPF 180C Dry film 8 Mfd 280 100°C (212°F) MH350-1A Electrical characteristics System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Standard Package 6 Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) General characteristics Lamp M98, M143 70W Ceramic Metal Halide No. Items Per Sales Unit 1 Safety and performance UL Listed 1 – 70W MH M98 or M143 Quad (120/208/240/277V) Type Distributor Kit 0.25 in (6.35 mm) 2.0 2.0 5.00 lbs Side 2.7 in (68.58 mm) 2.813 in x 3.939 in T12 Fluorescent Ballasts 120 61 0.60 A 1 0.82 1.16 A 0.61 A 264V 96V 90 -22 / -30 3 C Metal Halide Supply Current Frequency 4.6 in (116.84 mm) Specifications by lamp and line voltage 86847 – GEM70MLTLC3D-5 Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info 5.25 in (133.35 mm) 1.25 in (31.75 mm) 60 Hz Type Distributor Kit Specifications by line voltage Safety and performance Wiring diagram HID H6 – see example on page 180 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) Width (W) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) A B Weight Exit Type Nominal Length Frame Size (H x L) Order information No. Items Per Sales Unit 1 System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Magnetic – Core and Coil M98 480 5% HX-HPF 180C Dry film 8 Mfd 280 100°C (212°F) Supply Current Frequency Specifications by lamp and line voltage Lamp M110, M148 50W Quartz Metal Halide Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics 60 Hz Order information Type Distributor Kit 1 – 70W MH M98 or M143 480 General characteristics Wiring diagram HID W-(H)-86824-86847 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 1.0 B 2.0 Weight 3.40 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Electrical characteristics Supply Current Frequency Metal Halide T5 Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86839 – GEM7048TLC3D-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 86824 – GEM50MLTLC3D-5 Quick Reference Guides gelighting.com Metal Halide Metal Halide For 20 – 175W Metal Halide HID Lamps For 20 – 175W Metal Halide HID Lamps Metal Halide 1 – 100W MH M90 or M140 480 General characteristics Dimensions General characteristics Wiring diagram HID W-(F)-87068-86667 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 3.0 Weight 5.00 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Electrical characteristics Supply Current Frequency Order information No. Items Per Standard Package 6 150W Quartz Metal Halide 0.56 A 0.33 A 271V 384V 90 -22 / -30 2 C cUL Listed General characteristics Dimensions • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 Volt) featuring a 480-Volt tap 87210 – GEM175ML5AC3-5 Metal Halide 1 – 175W MH M57 or H39 5-Tap (120/208/240/277/480V) Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil M57, H39, M109 120/208/240/277/480 10% CWA 180C Oil filled 10 Mfd 400 100°C (212°F) Supply Current Frequency Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.0 B 4.0 Weight 3.40 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Lead lengths Orange Violet and Black Violet/White Black/Yellow 60 Hz Order information No. Items Per Standard Package 6 Type Distributor Kit Specifications by lamp and line voltage 240 186 0.80 A 1 0.81 1.68 A 0.89 A 257V 192V 90 -22 / -30 5 A Lamp M57, H39, M109 277 186 0.70 A 1 0.81 1.39 A 0.77 A 257V 222V 90 -22 / -30 4 A Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed See page 195 for warranty information. 120 202 1.70 A 1 0.87 1.70 A 0.60 A 307V 96V 90 -22 / -30 5 D cUL Listed See page 195 for warranty information. 208 202 1.00 A 1 0.87 1.00 A 0.37 A 307V 166V 90 -22 / -30 3 C 240 202 0.90 A 1 0.87 0.90 A 0.32 A 307V 192V 90 -22 / -30 3 C 277 202 0.80 A 1 0.87 0.80 A 0.28 A 307V 222V 90 -22 / -30 2 C 480 202 0.40 A 1 0.87 0.40 A 0.21 A 307V 384V 90 -22 / -30 1.5 C UL Listed 147 HID Electromagnetic Ballasts cUL Listed 208 186 1.00 A 1 0.81 1.95 A 1.03 A 257V 166V 90 -22 / -30 5 B No. Items Per Standard Package 6 Specifications by lamp and line voltage Specifications by line voltage 120 186 1.60 A 1 0.81 3.37 A 1.86 A 257V 96V 90 -22 / -30 10 A No. Items Per Sales Unit 1 HID Electronic Ballasts No. Items Per Sales Unit 1 480 185 0.40 A 1 0.83 0.85 A 0.38 A 264V 384V 90 -22 / -30 2 E UL Listed Electrical characteristics 60 Hz Order information 146 cUL Listed System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise General characteristics Wiring diagram HID W-(H)-86675-86718 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.3 B 4.0 Weight 7.00 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Electrical characteristics Safety and performance System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Specifications by line voltage Compact Fluorescent Ballasts Magnetic – Core and Coil M142, M102 120/208/240/277 5% HX-HPF 180C Dry film 16 Mfd 300 100°C (212°F) MH350-1A Lamp M107 480 185 0.40 A 1 0.81 0.85 A 0.38 A 264V 384V 90 -22 / -30 2 E Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 1 – 150W MH M102 or M142 Quad (120/208/240/277V) 150W Quartz Metal Halide Specifications by line voltage Safety and performance UL Listed Metal Halide System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Standard Package 6 T12 Fluorescent Ballasts Lamp M102, M142 150W Ceramic Metal Halide 480 120 0.30 A 1 System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Sales Unit 1 Specifications by lamp and line voltage Specifications by line voltage 86718 – GEM150MLTLC3D-5 Lamp M142, M102 150W Ceramic Metal Halide 60 Hz Type Distributor Kit Specifications by lamp and line voltage Type Distributor Kit Wiring diagram HID W-(E)-87087-86711-86876 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.3 B 3.9 Weight 7.00 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Order information No. Items Per Sales Unit 1 Supply Current Frequency Magnetic – Core and Coil M142, M102, M107 480 5% HX-HPF 180C Dry film 16 Mfd 280 100°C (212°F) MH350-1A Electrical characteristics 60 Hz Type Distributor Kit Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info T5 Fluorescent Ballasts Magnetic – Core and Coil M90 or M140 480 5% HX-HPF 180C Dry film 12 Mfd 280 100°C (212°F) MH350-1A Supply Current Frequency Safety and performance Metal Halide 1 – 150W MH M102 or M142 480 Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Lamp M90, M140 100W Ceramic Metal Halide • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86711 – GEM15048TLC3D-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86667 – GEM10048TLC3D-5 Quick Reference Guides gelighting.com Metal Halide Metal Halide For 20 – 175W Metal Halide HID Lamps For 250 – 1500W Metal Halide HID Lamps Metal Halide 1 – 175W MH M57 or H39 Quad (120/208/240/277V) General characteristics Dimensions Magnetic – Core and Coil M57, M107, H39 120/208/240/277 10% CWA 180C Oil filled 10 Mfd 400 100°C (212°F) 60 Hz 60 Hz Order information Type Distributor Kit No. Items Per Standard Package 6 cUL Listed No. Items Per Standard Package 6 208 210 1.00 A 1 0.83 1.00 A 0.56 A 302V 166V 90 -22 / -30 3 B 240 210 0.90 A 1 0.83 0.90 A 0.48 A 302V 192V 90 -22 / -30 3 B 277 210 0.80 A 1 0.83 0.80 A 0.42 A 302V 222V 90 -22 / -30 2 C Lamp M107 Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power factor (>=) % Min. starting temperature Fuse rating UL bench top rise 120 210 1.80 A 1 208 210 1.00 A 1 240 210 0.90 A 1 277 210 0.80 A 1 1.80 A 0.96 A 302V 96V 90 -22 / -30 5 B 1.00 A 0.56 A 302V 166V 90 -22 / -30 3 B 0.90 A 0.48 A 302V 192V 90 -22 / -30 3 B 0.80 A 0.42 A 302V 222V 90 -22 / -30 2 C Lamp M58, H37 250W Quartz Metal Halide Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor 175W Quartz Ballast Efficiency Factor Metal Halide) Max Input Current 250W Mercury Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 120 280 2.50 A 1 0.89 2.60 A 1.50 A 290V 96V 90 -22 / -30 8 B Safety and performance cUL Listed 208 280 1.40 A 1 0.89 1.60 A 1.00 A 290V 166V 90 -22 / -30 5 B 240 280 1.25 A 1 0.89 1.30 A 0.80 A 290V 192V 90 -22 / -30 4 B 277 280 1.10 A 1 0.89 1.20 A 0.70 A 290V 222V 90 -22 / -30 3 C T12 Fluorescent Ballasts 120 210 1.80 A 1 0.83 1.80 A 0.96 A 302V 96V 90 -22 / -30 5 B No. Items Per Sales Unit 1 Specifications by lamp and line voltage Specifications by line voltage Safety and performance Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.0 B 4.3 Weight 9.00 lbs Exit Type Side Nominal Length 3.2 in (82.55 mm) Frame Size (H x L) 2.813 in x 3.939 in Lead lengths Orange Violet and Black Violet/White Black/Yellow Electrical characteristics No. Items Per Sales Unit 1 System Wattage (W) Nominal Current Ballast Factor 150W Quartz Ballast Efficiency Factor Metal Halide Max Input Current 175W Mercury Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=) % Min. Starting Temp Fuse Rating UL Bench Top Rise Magnetic – Core and Coil M58, H37 120/208/240/277/480 10% CWA 180C Oil filled 15 Mfd 400 100°C (212°F) Supply Current Frequency Specifications by lamp and line voltage Lamp M57, H39 175W Quartz Metal Halide Dimensions General characteristics Order information Type Distributor Kit 1 – 250W MH M58 or H37 5-Tap (120/208/240/277/480V) Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Wiring diagram HID W-(C)-86655-86698-86741 – see example on page 181 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 1.0 B 2.0 Weight 3.40 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Electrical characteristics Supply Current Frequency Metal Halide T5 Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap 87211 – GEM250ML5AC3-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 86741 – GEM175MLTAC3-5 Quick Reference Guides gelighting.com 480 280 0.65 A 1 0.89 0.70 A 0.50 A 290V 384V 90 -22 / -30 2 C UL Listed UL Listed Metal Halide 1 – 250W MH M58 or H37 Quad (120/208/240/277V) Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 86765 – GEM250MLTAC3-5 Dimensions General characteristics Magnetic – Core and Coil M58, H37 120/208/240/277 10% CWA 180C Oil filled 15 Mfd 400 100°C (212°F) Wiring diagram HID W-(C)-86765-86814 – see example on page 181 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.0 B 4.3 Weight 9.00 lbs Exit Type Side Nominal Length 3.2 in (82.55 mm) Frame Size (H x L) 2.813 in x 3.939 in Compact Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics Supply Current Frequency 60 Hz Order information No. Items Per Sales Unit 1 HID Electronic Ballasts Type Distributor Kit No. Items Per Standard Package 6 Specifications by lamp and line voltage Safety and performance 148 See page 195 for warranty information. 120 294 2.65 A 1 0.85 2.60 A 1.88 A 315V 96V 90 -22 / -30 8 C cUL Listed See page 195 for warranty information. 208 294 1.50 A 1 0.85 1.58 A 1.15 A 315V 166V 90 -22 / -30 5 D 240 294 1.30 A 1 0.85 1.30 A 0.95 A 315V 192V 90 -22 / -30 4 C 277 294 1.13 A 1 0.85 1.12 A 0.86 A 315V 222V 90 -22 / -30 3 C UL Listed 149 HID Electromagnetic Ballasts Lamp Specifications by line voltage M58, H37 250W Quartz System Wattage (W) Metal Halide Nominal Current Ballast Factor 175W Quartz Ballast Efficiency Factor Metal Halide Max Input Current 250W Mercury Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Metal Halide Metal Halide For 250 – 1500W Metal Halide HID Lamps For 250 – 1500W Metal Halide HID Lamps Metal Halide 1 – 250W MH M58 or H37 5-Tap (120/208/240/277/480V) Dimensions General characteristics Magnetic – Core and Coil M58, H37 120/208/240/277/480 10% CWA 180C Oil filled 15 Mfd 400 100°C (212°F) 60 Hz Order information Type Distributor Kit No. Items Per Sales Unit 1 No. Items Per Standard Package 3 Safety and performance cUL Listed 208 293 2.30 A 1 0.85 1.40 A 1.40 A 300V 166V 90 -22 / -30 5 A 240 293 2.00 A 1 0.85 1.30 A 1.20 A 300V 192V 90 -22 / -30 4 A 277 293 1.70 A 1 0.85 1.10 A 1.00 A 300V 222V 90 -22 / -30 3 A 480 293 1.00 A 1 0.85 0.65 A 0.60 A 300V 384V 90 -22 / -30 2 A 360W Quartz Metal Halide 400W Mercury Dimensions General characteristics 60 Hz Order information 360W Quartz Metal Halide 400W Mercury 150 cUL Listed 120 446 3.80 A 1 0.93 3.80 A 3.17 A 289V 96V 90 -22 / -30 10 C System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise cUL Listed 208 446 2.20 A 1 0.93 2.20 A 1.84 A 289V 166V 90 -22 / -30 8 C 240 446 1.90 A 1 0.93 1.90 A 1.60 A 289V 192V 90 -22 / -30 5 C 277 446 1.70 A 1 0.93 1.70 A 1.39 A 289V 222V 90 -22 / -30 5 C UL Listed • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86803 – GEM40048TAC4-5 Metal Halide 1 – 400W MH M59 or H33 480 Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil M59, H33 480 10% CWA 180C Oil filled 24 Mfd 400 100°C (212°F) Wiring diagram HID W-(J)-86650-86693-86803 – see example on page 182 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 12.50 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 4.75 in Electrical characteristics Supply Current Frequency 60 Hz Order information No. Items Per Sales Unit 1 No. Items Per Standard Package 3 Specifications by lamp and line voltage 208 446 2.10 A 1 0.92 2.10 A 1.31 A 300V 166V 90 -22 / -30 8 E 240 446 1.90 A 1 0.92 1.90 A 1.11 A 300V 192V 90 -22 / -30 5 E 277 446 1.60 A 1 0.92 1.60 A 1.00 A 300V 222V 90 -22 / -30 5 E Lamp M59 400W Quartz Metal Halide 480 446 0.90 A 1 0.92 0.90 A 0.60 A 300V 384V 90 -22 / -30 5 E 360W Quartz Metal Halide Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed See page 195 for warranty information. cUL Listed See page 195 for warranty information. 480 432 0.90 A 1 0.93 0.90 A 0.60 A 297V 384V 90 -22 / -30 5 A Lamp H33 400W Mercury Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 480 458 1.00 A 1 0.87 1.00 A 0.60 A 300V 384V 90 -22 / -30 5 E UL Listed 151 HID Electromagnetic Ballasts Safety and performance Specifications by line voltage Type Distributor Kit Specifications by line voltage 120 446 3.70 A 1 0.92 3.70 A 2.19 A 300V 96V 90 -22 / -30 10 E No. Items Per Standard Package 3 HID Electronic Ballasts No. Items Per Standard Package 3 Specifications by lamp and line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Sales Unit 1 General characteristics Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 12.50 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 4.75 in Lead lengths Orange Violet and Black Violet/White Black/Yellow Electrical characteristics Lamp M59, H33 400W Quartz Metal Halide 60 Hz Compact Fluorescent Ballasts Magnetic – Core and Coil M59, H33 120/208/240/277/480 10% CWA 180C Oil filled 24 Mfd 400 100°C (212°F) No. Items Per Sales Unit 1 0.25 in (6.35 mm) 2.0 4.0 11.90 lbs Side 3.7 in (95.25 mm) 4.25 in x 4.75 in Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 Volt) featuring a 480-Volt tap 1 – 400W MH M59 or H33 5-Tap (120/208/240/277/480V) A1 C&C Type Distributor Kit 4.6 in (116.84 mm) Order information Safety and performance Metal Halide Supply Current Frequency 5.25 in (133.35 mm) 1.25 in (31.75 mm) Electrical characteristics Supply Current Frequency Lamp M59, H33 400W Quartz Metal Halide UL Listed 72300 – GEM400ML5AA4-5 Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Wiring diagram HID H21 – see example on page 180 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) Width (W) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) A B Weight Exit Type Nominal Length Frame Size (H x L) T12 Fluorescent Ballasts 120 293 4.00 A 1 0.85 2.50 A 2.50 A 300V 96V 90 -22 / -30 8 A Magnetic – Core and Coil M59, H33 120/208/240/277 10% CWA 180C Oil filled 24 Mfd 400 100°C (212°F) Specifications by lamp and line voltage Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Type Distributor Kit Specifications by lamp and line voltage Lamp M58, H37 1 – 400W MH M59 or H33 Quad (120/208/240/277V) A1 C&C General characteristics Wiring diagram HID W-(K)-87212-87213 – see example on page 183 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 1.8 B 3.6 Weight 10.80 lbs Exit Type Side Nominal Length 3.2 in (82.55 mm) Frame Size (H x L) 4.25 in x 4.75 in Lead lengths Orange Violet and Black Violet/White Black/Yellow Electrical characteristics Supply Current Frequency Metal Halide T5 Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 72149 – GEM400MLTAA4-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap 87212 – GEM250ML5AC4-5 Quick Reference Guides gelighting.com Metal Halide Metal Halide For 250 – 1500W Metal Halide HID Lamps For 250 – 1500W Metal Halide HID Lamps Metal Halide 1 – 1000W MH M47 or H36 480 Dimensions General characteristics Electrical characteristics No. Items Per Standard Package 2 cUL Listed 1000W Mercury Dimensions General characteristics 60 Hz No. Items Per Sales Unit 1 1 – 1500W MH M48 480 Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil M48 480 10% CWA 180C Oil filled 32 Mfd 525 100°C (212°F) Wiring diagram HID W-(J)-86650-86693-86803 – see example on page 182 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 7.75 in (196.85 mm) Width (W) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 4.0 B 6.0 Weight 30.00 lbs Exit Type Side Nominal Length 5.2 in (133.35 mm) Frame Size (H x L) 4.25 in x 6.00 in Electrical characteristics Supply Current Frequency 60 Hz Order information No. Items Per Sales Unit 1 No. Items Per Standard Package 2 Specifications by lamp and line voltage 208 1,103 5.40 A 1 0.91 5.40 A 3.71 A 445V 166V 90 -22 / -30 15 C 240 1,103 4.70 A 1 0.91 4.70 A 3.20 A 445V 192V 90 -22 / -30 10 C 277 1,103 4.10 A 1 0.91 4.10 A 2.79 A 445V 222V 90 -22 / -30 10 C 480 1,103 2.40 A 1 0.91 2.40 A 1.65 A 445V 384V 90 -22 / -30 10 D Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed See page 195 for warranty information. cUL Listed See page 195 for warranty information. 480 1,581 3.10 A 1 0.95 3.10 A 3.18 A 449V 384V 90 -22 / -30 10 G UL Listed 153 HID Electromagnetic Ballasts cUL Listed • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement Metal Halide Lamp M48 1500W Quartz Metal Halide Specifications by line voltage 120 1,103 9.30 A 1 0.91 9.30 A 6.34 A 445V 96V 90 -22 / -30 20 E UL Listed 86693 – GEM150048TAC5M5-5 Type Distributor Kit No. Items Per Standard Package 2 Specifications by lamp and line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 277 1,067 3.90 A 1 0.94 3.90 A 3.30 A 421V 222V 90 -22 / -30 10 B HID Electronic Ballasts Order information Type Distributor Kit 240 1,067 4.50 A 1 0.94 4.50 A 3.79 A 421V 192V 90 -22 / -30 10 B General characteristics Wiring diagram HID W-(K)-87212-87213 – see example on page 183 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 7.75 in (196.85 mm) Width (W) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.0 B 5.0 Weight 21.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 6.00 in Lead lengths Orange Violet and Black Violet/White Black/Yellow Electrical characteristics cUL Listed 208 1,067 5.00 A 1 0.94 5.00 A 4.35 A 421V 166V 90 -22 / -30 15 B Compact Fluorescent Ballasts Magnetic – Core and Coil M47, H36 120/208/240/277/480 10% CWA 180C Oil filled 24 Mfd 480 100°C (212°F) 120 1,067 9.00 A 1 0.94 9.00 A 7.44 A 421V 96V 90 -22 / -30 20 B System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 Volt) featuring a 480-Volt tap 1 – 1000W MH M47 or H36 5-Tap (120/208/240/277/480V) Supply Current Frequency Specifications by line voltage Safety and performance UL Listed Metal Halide Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info No. Items Per Standard Package 2 T12 Fluorescent Ballasts 480 1,052 2.20 A 1 0.95 2.20 A 1.83 A 430V 384V 90 -22 / -30 10 E System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Sales Unit 1 Specifications by lamp and line voltage Lamp M47, H36 1000W Quartz Metal Halide 87213 – GEM1000ML5AA5-5 152 60 Hz Type Distributor Kit Specifications by line voltage Safety and performance Wiring diagram HID W-(C)-86655-86698-86741 – see example on page 181 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 7.75 in (196.85 mm) Width (W) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.0 B 5.0 Weight 21.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 6.00 in Order information No. Items Per Sales Unit 1 Specifications by lamp and line voltage 1000W Mercury Magnetic – Core and Coil M47, H36 120/208/240/277 10% CWA 180C Oil filled 24 Mfd 480 100°C (212°F) Supply Current Frequency Order information Lamp M47, H36 1000W Quartz Metal Halide Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics 60 Hz Type Distributor Kit Safety and performance Dimensions General characteristics Wiring diagram HID W-(J)-86650-86693-86803 – see example on page 182 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 7.75 in (196.85 mm) Width (W) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.0 B 5.0 Weight 21.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 6.00 in T5 Fluorescent Ballasts Magnetic – Core and Coil M47, H36 480 10% CWA 180C Oil filled 24 Mfd 480 100°C (212°F) Supply Current Frequency 1000W Mercury Metal Halide 1 – 1000W MH M47 or H36 Quad (120/208/240/277V) Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Lamp M47, H36 1000W Quartz Metal Halide • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 86655 – GEM1000MLTAA5-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications. • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity. • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86650 – GEM100048TAC5-5 Quick Reference Guides gelighting.com Metal Halide Pulse Start For 250 – 1500W Metal Halide HID Lamps For 175 – 1000W Pulse Start Metal Halide HID Lamps Metal Halide 1 – 1500W MH M48 Quad (120/208/240/277V) Dimensions General characteristics Magnetic – Core and Coil M48 240/277 10% CWA 180C Oil filled 32 Mfd 525 100°C (212°F) 1 – 175W PS M137 or M152 Quad (120/208/240/277V) Dimensions General characteristics Wiring diagram HID W-(C)-86655-86698-86741 – see example on page 181 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 7.75 in (196.85 mm) Width (W) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 4.0 B 6.0 Weight 30.00 lbs Exit Type Side Nominal Length 5.2 in (133.35 mm) Frame Size (H x L) 4.25 in x 6.00 in Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil M153, M137 120/208/240/277 10% CWA 180C Oil filled 10 Mfd 400 100°C (212°F) MH350-1A Wiring diagram HID W-(A)-46934-86885-86935 – see example on page 181 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 7.50 lbs Exit Type Side Nominal Length 3.2 in (82.55 mm) Frame Size (H x L) 2.813 in x 3.939 in Electrical characteristics Electrical characteristics Supply Current Frequency Supply Current Frequency 60 Hz 60 Hz Order information Order information Type Distributor Kit No. Items Per Sales Unit 1 Type Distributor Kit No. Items Per Standard Package 2 cUL Listed 208 1,602 7.70 A 1 0.94 7.70 A 7.46 A 440V 166V 90 -22 / -30 25 A No. Items Per Standard Package 6 240 1,602 6.80 A 1 0.94 6.80 A 6.52 A 440V 192V -22 / -30 20 A Lamp M153 250W Quartz Metal Halide 277 1,602 6.00 A 1 0.94 6.00 A 5.75 A 440V 222V 90 -22 / -30 20 A Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=) % Min. Starting Temp Fuse Rating UL Bench Top Rise Safety and performance UL Listed 120 204 1.70 A 1 1.23 1.70 A 0.76 A 281V 96V 90 -22 / -30 5 C 208 204 1.00 A 1 1.23 1.00 A 0.36 A 281V 166V 90 -22 / -30 3 D cUL Listed 240 204 0.90 A 1 1.23 0.90 A 0.38 A 281V 192V 90 -22 / -30 3 B 277 204 0.80 A 1 1.23 0.80 A 0.33 A 281V 222V 90 -22 / -30 2 B Lamp M137 175W Quartz Metal Halide Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power factor (>=) % Min. starting temperature Fuse rating UL bench top rise 120 204 1.70 A 1 0.86 1.70 A 0.76 A 281V 96V 90 -22 / -30 5 C 208 204 1.00 A 1 0.86 1.00 A 0.36 A 281V 166V 90 -22 / -30 3 D 240 204 0.90 A 1 0.86 0.90 A 0.38 A 281V 192V 90 -22 / -30 3 B 277 204 0.80 A 1 0.86 0.80 A 0.33 A 281V 222V 90 -22 / -30 2 B T12 Fluorescent Ballasts 120 1,602 13.70 A 1 0.94 13.70 A 12.95 A 440V 96V 90 -22 / -30 40 E No. Items Per Sales Unit 1 Specifications by lamp and line voltage Specifications by lamp and line voltage Specifications by line voltage Lamp M48 1500W Quartz System Wattage (W) Nominal Current Metal Halide Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance Pulse Start T5 Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 86885 – GEP175MLTAC3-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 86698 – GEM1500MLTAC5-5 Quick Reference Guides gelighting.com UL Listed Pulse Start Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86876 – GEP17548TAC3-5 1 – 175W PS M137 or M152 480 Dimensions General characteristics Magnetic – Core and Coil M152, M137 120/480 10% CWA 180C Oil filled 10 Mfd 400 100°C (212°F) MH350-1A Wiring diagram HID W-(E)-87087-86711-86876 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 7.00 lbs Exit Type Side Nominal Length 3.2 in (82.55 mm) Frame Size (H x L) 2.813 in x 3.939 in Compact Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics Supply Current Frequency 60 Hz Type Distributor Kit No. Items Per Sales Unit 1 HID Electronic Ballasts Order information No. Items Per Standard Package 6 Specifications by lamp and line voltage Lamp M152, M137 175W Quartz Metal Halide Specifications by line voltage Safety and performance 154 See page 195 for warranty information. cUL Listed See page 195 for warranty information. 120 210 1.85 A 1 0.83 480 214 0.50 A 1 0.82 0.50 A 0.14 A 273V 0.55 A 315V 96V 90 384V 2 C 90 -22 / -30 2 C UL Listed 155 HID Electromagnetic Ballasts System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Pulse Start Pulse Start For 175 – 1000W Pulse Start Metal Halide HID Lamps For 175 – 1000W Pulse Start Metal Halide HID Lamps Pulse Start 1 – 250W PS M138 or M153 Quad (120/208/240/277V) Dimensions General characteristics Magnetic – Core and Coil M153, M138 120/208/240/277 10% CWA 180C Oil filled 15 Mfd 400 100°C 212°F) MH350-1A Wiring diagram HID W-(A)-86959-86984-87008 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Slots (MS) Mount Width (X or F) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 11.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 4.75 in 60 Hz Order information No. Items Per Sales Unit 1 No. Items Per Standard Package 3 Type Distributor Kit System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance cUL Listed No. Items Per Standard Package 3 208 284 1.40 A 1 0.88 1.40 A 1.02 A 255V 166V 90 -22 / -30 5 A 240 284 1.30 A 1 0.88 1.30 A 0.89 A 255V 192V 90 -22 / -30 5 A 277 284 1.10 A 1 0.88 1.10 A 0.77 A 255V 222V 90 -22 / -30 3 B Specifications by line voltage Safety and performance UL Listed Pulse Start 1 – 250W PS M138 or M153 480 cUL Listed 208 370 1.80 A 1 0.86 1.80 A 1.04 A 269V 166V 90 -22 / -30 7 B 240 370 1.60 A 1 0.86 1.60 A 0.87 A 269V 192V 90 -22 / -30 5 B 277 370 1.40 A 1 0.86 1.40 A 0.76 A 269V 222V 90 -22 / -30 5 A UL Listed • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86952 – GEP32048TAC4M-5 Pulse Start Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86926 – GEP25048TAC4-5 120 370 3.10 A 1 0.86 3.10 A 1.75 A 269V 96V 90 -22 / -30 8 D System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise T12 Fluorescent Ballasts Lamp M154, M132 Specifications by line voltage 120 284 2.50 A 1 0.88 2.50 A 1.78 A 255V 96V 90 -22 / -30 8 A No. Items Per Sales Unit 1 Specifications by lamp and line voltage Specifications by lamp and line voltage 1 – 320W PS M132 or M154 480 Dimensions General characteristics Magnetic – Core and Coil M153, M138 480 10% CWA 180C Oil filled 15 Mfd 400 100°C (212°F) MH350-1A Dimensions General characteristics Wiring diagram HID W-(E)-86926 – see example on page 182 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 3.0 Weight 9.00 lbs Exit Type Side Nominal Length 3.2 in (82.55 mm) Frame Size (H x L) 4.25 in x 4.75 in Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil M154, M132 480 10% CWA 180C Oil filled 21 Mfd 345 100°C (212°F) MH350-1A Wiring diagram HID W-(D)-86952-86999 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Height (H) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 12.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 4.75 in Electrical characteristics Electrical characteristics Supply Current Frequency Supply Current Frequency 60 Hz Compact Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info 60 Hz Order information No. Items Per Sales Unit 1 Type Distributor Kit No. Items Per Standard Package 3 Specifications by lamp and line voltage Specifications by line voltage cUL Listed 480 290 0.60 A 1 0.86 0.60 A 0.48 A 254V 384V 90 -22 / -30 2 C No. Items Per Standard Package 3 Specifications by lamp and line voltage Lamp M138 Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Lamp M154, M132 480 290 0.60 A 1 Specifications by line voltage 480 369 0.80 A 1 0.87 0.80 A 0.50 A 268V 384V 90 -22 / -30 3 C System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 0.60 A 0.48 A 254V 384V 90 -22 / -30 2 C Safety and performance UL Listed See page 195 for warranty information. cUL Listed See page 195 for warranty information. UL Listed 157 HID Electromagnetic Ballasts System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Sales Unit 1 HID Electronic Ballasts Order information Type Distributor Kit 156 Magnetic – Core and Coil M154, M132 120/208/240/277 10% CWA 180C Oil filled 21 Mfd 345 100°C (212°F) MH350-1A Supply Current Frequency Order information Safety and performance Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics 60 Hz Type Distributor Kit Lamp M153 250W Quartz Metal Halide 1 – 320W PS M132 or 154 Quad (120/208/240/277V) General characteristics Wiring diagram HID W-(A)-46934-86885-86935 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 3.0 Weight 9.00 lbs Exit Type Side Nominal Length 3.2 in (82.55 mm) Frame Size (H x L) 4.25 in x 4.75 in Electrical characteristics Supply Current Frequency Lamp M153, M138 250W Quartz Metal Halide Pulse Start T5 Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 86959 – GEP320MLTAC4-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 86935 – GEP250MLTAC4-5 Quick Reference Guides gelighting.com Pulse Start Pulse Start For 175 – 1000W Pulse Start Metal Halide HID Lamps For 175 – 1000W Pulse Start Metal Halide HID Lamps Pulse Start 1 – 320W PS M132 or M154 TRI-Voltage 120 277 347 Dimensions Electrical characteristics No. Items Per Standard Package 3 cUL Listed 277 400 1.30 A 1 0.88 1.30 A 0.83 A 281V 222V 90 -22 / -30 4 C Lamp M155, M135 400W Quartz Metal Halide 347 400 1.10 A 1 0.88 1.10 A 0.66 A 281V 150V 90 -22 / -30 3 C Specifications by line voltage Pulse Start 1 – 350W PS M131 Quad (120/208/240/277V) Dimensions General characteristics UL Listed • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 87008 – GEP400MLTAC4-5 Pulse Start 1 – 400W PS M135 or M155 Quad (120/208/240/277V) Dimensions General characteristics Wiring diagram HID W-(A)-86959-86984-87008 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 12.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 4.75 in Electrical characteristics Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil M155, M135 120/208/240/277 10% CWA 180C Oil filled 24 Mfd 400 100°C (212°F) MH350-1A Wiring diagram HID W-(A)-86959-86984-87008 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 3.8 Weight 12.00 lbs Exit Type Side Nominal Length 4.6 in (119.12 mm) Frame Size (H x L) 4.25 in x 4.75 in Compact Fluorescent Ballasts Magnetic – Core and Coil M131 120/208/240/277 10% CWA 180C Oil filled 21.5 Mfd 345 100°C (212°F) MH350-1A cUL Listed Electrical characteristics Supply Current Frequency 60 Hz Supply Current Frequency Order information 60 Hz No. Items Per Sales Unit 1 No. Items Per Standard Package 3 Type Distributor Kit Specifications by lamp and line voltage 240 396 1.70 A 1 0.88 1.70 A 1.12 A 262V 192V 90 -22 / -30 5 D Lamp M155, M135 400W Quartz Metal Halide 277 396 1.40 A 1 0.88 1.40 A 0.99 A 262V 222V 90 -22 / -30 5 D UL Listed See page 195 for warranty information. Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 120 443 3.90 A 1 0.90 3.90 A 3.16 A 259V 96V 90 -22 / -30 10 B Safety and performance cUL Listed See page 195 for warranty information. 208 443 2.20 A 1 0.90 2.20 A 1.85 A 259V 166V 90 -22 / -30 7 C 240 443 2.00 A 1 0.90 2.00 A 1.60 A 259V 192V 90 -22 / -30 5 D 277 443 1.70 A 1 0.90 1.70 A 1.39 A 259V 222V 90 -22 / -30 5 C UL Listed 159 HID Electromagnetic Ballasts cUL Listed 208 396 1.90 A 1 0.88 1.90 A 1.31 A 262V 166V 90 -22 / -30 7 D No. Items Per Standard Package 3 Specifications by lamp and line voltage Specifications by line voltage 120 396 3.40 A 1 0.88 3.40 A 2.31 A 262V 96V 90 -22 / -30 10 D No. Items Per Sales Unit 1 HID Electronic Ballasts Order information Type Distributor Kit Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 480 465 1.00 A 1 0.86 1.00 A 0.80 A 275V 384V 90 -22 / -30 3 D System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed 86984 – GEP350MLTAC4-5 Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info No. Items Per Standard Package 3 T12 Fluorescent Ballasts 120 400 3.00 A 1 0.88 3.00 A 1.89 A 281V 96V 90 -22 / -30 8 C No. Items Per Sales Unit 1 Specifications by lamp and line voltage Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 158 60 Hz Type Distributor Kit Specifications by lamp and line voltage Safety and performance Wiring diagram HID W-(D)-86952-86999 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 12.00 lbs Exit Type Side Nominal Length 4.6 in (119.12 mm) Frame Size (H x L) 4.25 in x 4.75 in Order information No. Items Per Sales Unit 1 System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Magnetic – Core and Coil M155, M135 480 10% CWA 180C Oil filled 24 Mfd 400 100°C (212°F) MH350-1A Supply Current Frequency Order information Lamp M131 350W Quartz Metal Halide Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics 60 Hz Type Distributor Kit Safety and performance Dimensions General characteristics Wiring diagram HID W-(L)-86968 – see example on page 183 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.3 in (134.62 mm) Width (W) 1.3 in (33.02 mm) Mounting dimensions Mount Length (M) 4.60 in (116.84 mm) Mount Slots (MS) 0.3 in (7.62 mm) A B Weight 12.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in (4.75 mm) T5 Fluorescent Ballasts Magnetic – Core and Coil M154, M132 120/277/347 10% CWA 180C Oil Filled 21 Mfd 400 100°C (212°F) MH350-1A Supply Current Frequency Lamp M154, M132 Pulse Start 1 – 400W PS M135 or M155 480 General characteristics Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86999 – GEP40048TAC4-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86968 – GEP320TRIAC4-5 Quick Reference Guides gelighting.com Pulse Start Pulse Start For 175 – 1000W Pulse Start Metal Halide HID Lamps For 175 – 1000W Pulse Start Metal Halide HID Lamps Pulse Start 1 – 750W PS M149 480 Dimensions General characteristics Electrical characteristics No. Items Per Standard Package 2 60 Hz Type Distributor Kit Specifications by lamp and line voltage cUL Listed UL Listed 1 – 750W PS M149 Quad (120/208/240/277V) Dimensions General characteristics System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 120 1071 8.80 A 1 0.93 8.80 A 5.70 A 420V 96V 90 -22 / -30 20 D Safety and performance cUL Listed 208 1071 5.10 A 1 0.93 5.10 A 5.70 A 420V 166V 90 -22 / -30 15 B 240 1071 4.30 A 1 0.93 4.30 A 5.70 A 420V 192V 90 -22 / -30 10 B 277 1071 4.00 A 1 0.93 4.00 A 5.70 A 420V 222V 90 -22 / -30 10 B UL Listed 72282 – GEP1000ML5AC5-5 Pulse Start 1 – 1000W PS M141 5-Tap (120/208/240/277/480V) Dimensions General characteristics Wiring diagram HID W-(A)-46934-86885-86935 – see example on page 181 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 7.75 in (196.85 mm) Width (W) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.0 B 5.0 Weight 22.00 lbs Exit Type Side Nominal Length 4.2 in (107.95 mm) Frame Size (H x L) 4.25 in x 6.00 in Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil M141 120/208/240/277/480 10% CWA 180C Oil filled 24 Mfd 480 -30°C (-20°F) HPS1000-4B D (37-42 decibels) Wiring diagram HID W-(A)-87214-87215-87218 – see example on page 181 Case dimensions – Ref Drawing PC3 – see page 185 Width (W) 7.75 in (196.85 mm) Length (L) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) 6.1 in (154.94 mm) Mount Slots (MS) 0.25 in (9.52 mm) A 2.83 B 5.20 Weight 21.60 lbs Exit Type Side Nominal Length 4.25 in (107.95 mm) Frame Size (H x L) 4.25 in x 6.00 in Compact Fluorescent Ballasts Magnetic – Core and Coil M149 120/208/240/277 10% CWA 180C Oil filled 28 Mfd 400 100°C (212°F) MH750-1A Specifications by line voltage Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) Pulse Start Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info No. Items Per Standard Package 2 T12 Fluorescent Ballasts Lamp M141 480 809 1.80 A 1 0.93 1.80 A 1.04 A 351V 384V 90 -22 / -30 6 E System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Sales Unit 1 Specifications by lamp and line voltage Specifications by line voltage 46934 – GEP750MLTAC5-5 Electrical characteristics Electrical characteristics Supply Current Frequency Supply Current Frequency 60 Hz 60 Hz Order information No. Items Per Sales Unit 1 Type Distributor Kit No. Items Per Standard Package 2 Lamp M141 Specifications by line voltage 240 802 2.10 A 1 0.94 2.10 A 2.03 A 351V 192V 90 -22 / -30 8 B 277 802 1.80 A 1 0.94 1.80 A 1.76 A 351V 222V 90 -22 / -30 8 B UL Listed See page 195 for warranty information. Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 120 1112 9.30 A 1 0.90 9.30 A 5.70 A 450V 96V 90 -22 / -30 20 D Safety and performance cUL Listed See page 195 for warranty information. 208 1112 5.40 A 1 0.90 5.40 A 5.70 A 450V 166V 90 -22 / -30 15 C 240 1112 4.70 A 1 0.90 4.70 A 5.70 A 450V 192V 90 -22 / -30 10 C 277 1112 4.20 A 1 0.90 4.20 A 5.70 A 450V 222V 90 -22 / -30 10 D 480 1112 2.50 A 1 0.90 2.50 A 5.70 A 450V 384V 90 -22 / -30 10 E UL Listed 161 HID Electromagnetic Ballasts cUL Listed 208 802 2.40 A 1 0.94 2.40 A 2.32 A 351V 166V 90 -22 / -30 8 B No. Items Per Standard Package 2 Specifications by lamp and line voltage Specifications by lamp and line voltage 120 802 4.10 A 1 0.94 4.10 A 3.98 A 351V 96V 90 -22 / -30 15 B No. Items Per Sales Unit 1 HID Electronic Ballasts Order information Type Distributor Kit 160 Wiring diagram HID W-(A)-46934-86935 – see example on page 181 Case dimensions – Ref Drawing PC3 – see page 185 Width (W) 7.75 in (196.85 mm) Length (L) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) 6.1 in (154.94 mm) Mount Slots (MS) 0.25 in (9.52 mm) A 2.83 B 5.08 Weight 21.00 lbs Exit Type Side Nominal Length 4.25 in (107.95 mm) Frame Size (H x L) 4.25 in x 6.00 in Order information No. Items Per Sales Unit 1 Safety and performance Magnetic – Core and Coil M141 120/208/240/277 10% CWA 180C Oil filled 24 Mfd 480 100°C (212°F) HPS100-4B D (37-42 decibels) Supply Current Frequency Order information System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics 60 Hz Type Distributor Kit Lamp M149 750W Quartz Metal Halide Dimensions General characteristics Wiring diagram HID W-(D)-87048-87198-49636 – see example on page 181 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 7.75 in (196.85 mm) Width (W) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.0 B 5.0 Weight 21.00 lbs Exit Type Side Nominal Length 4.2 in (107.95 mm) Frame Size (H x L) 4.25 in x 6.00 in T5 Fluorescent Ballasts Magnetic – Core and Coil M149 480 10% CWA 180C Oil filled 24 Mfd 480 100°C (212°F) MH750-1A Supply Current Frequency Safety and performance Pulse Start 1 – 1000W PS M141 Quad (120/208/240/277V) Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Lamp M149 750W Quartz Metal Halide 72281 – GEP1000MLTAC5-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 46936 – GEP75048TAC5-5 Quick Reference Guides gelighting.com High Pressure Sodium High Pressure Sodium For 50 – 150W High Pressure Sodium HID Lamps For 50 – 150W High Pressure Sodium HID Lamps High Pressure Sodium 1 – 50W HPS S68 Quad (120/208/240/277V) General characteristics Dimensions Magnetic – Core and Coil S68 120/208/240/277 5% HX-HPF 180C Dry film 5 Mfd 280 100°C (212°F) HPS150-3A cUL Listed 208 69 0.40 A 1 0.72 0.54 A 0.43 A 122V 166V 90 -22 / -30 3 B 240 69 0.30 A 1 0.72 0.46 A 0.37 A 122V 192V 90 -22 / -30 3 B Lamp S62 70W High Pressure Sodium 277 69 0.30 A 1 0.72 0.40 A 0.32 A 122V 222V 90 -22 / -30 2 B General characteristics Dimensions Specifications by line voltage 480 97 0.20 A 1 0.72 0.34 A 0.34 A 123V 384V 90 -22 / -30 2 A System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise cUL Listed UL Listed • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 87074 – GES100MLTLC3D-5 High Pressure Sodium 1 – 100W HPS S54 Quad (120/208/240/277V) General characteristics Wiring diagram HID W-(H)-86587-87074 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 3.0 Weight 5.50 lbs Exit Type Side Nominal Length 2.7 in (69.85 mm) Frame Size (H x L) 2.813 in x 3.939 in Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil S54 120/208/240/277 5% HX-HPF 180C Dry film 10 Mfd 280 100°C (212°F) HPS150-3A 86635 Electrical characteristics Supply Current Frequency 60 Hz Wiring diagram HID W-(H)-86587-87074 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 6.20 lbs Exit Type Side Nominal Length 2.7 in (69.85 mm) Frame Size (H x L) 2.813 in x 3.939 in Compact Fluorescent Ballasts Magnetic – Core and Coil S62 120/208/240/277 5% HX-HPF 180C Dry film 7 Mfd 300 100°C (212°F) HPS150-3A Electrical characteristics 60 Hz Order information Order information Type Distributor Kit No. Items Per Standard Package 6 208 91 0.50 A 1 0.77 0.78 A 0.46 A 118V 166V 90 -22 / -30 3 B 240 91 0.40 A 1 0.77 0.67 A 0.39 A 118V 192V 90 -22 / -30 3 B 277 91 0.40 A 1 0.77 0.59 A 0.35 A 118V 222V 90 -22 / -30 2 B 150W High Pressure Sodium Specifications by line voltage Safety and performance UL Listed See page 195 for warranty information. 120 123 2.20 A 1 1.22 2.18 A 0.74 A 119V 96V 90 -22 / -30 8 B System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise cUL Listed See page 195 for warranty information. 208 123 1.30 A 1 1.22 1.27 A 0.43 A 119V 166V 90 -22 / -30 5 B 240 123 1.10 A 1 1.22 1.13 A 0.36 A 119V 192V 90 -22 / -30 5 B 277 123 0.90 A 1 1.22 0.94 A 0.31 A 119V 222V 90 -22 / -30 3 B UL Listed 163 HID Electromagnetic Ballasts cUL Listed No. Items Per Standard Package 6 Specifications by lamp and line voltage Lamp S54 100W High Pressure Sodium Specifications by line voltage 120 91 0.80 A 1 0.77 1.34 A 0.78 A 118V 96V 90 -22 / -30 5 B No. Items Per Sales Unit 1 HID Electronic Ballasts No. Items Per Sales Unit 1 Specifications by lamp and line voltage 162 No. Items Per Standard Package 6 Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 1 – 70W HPS S62 Quad (120/208/240/277V) Supply Current Frequency No. Items Per Sales Unit 1 Safety and performance UL Listed High Pressure Sodium Safety and performance 0.25 in (6.35 mm) 2.0 3.0 5.80 lbs Side 2.7 in (69.85 mm) 2.813 in x 3.939 in T12 Fluorescent Ballasts 120 69 0.70 A 1 0.72 0.93 A 0.74 A 122V 96V 90 -22 / -30 5 B System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 4.6 in (116.84 mm) Specifications by lamp and line voltage 86587 – GES70MLTLC3D-5 Lamp S62 70W High Pressure Sodium 5.25 in (133.35 mm) 1.25 in (31.75 mm) 60 Hz Type Distributor Kit Specifications by line voltage Type Distributor Kit Wiring diagram HID H6 – see example on page 180 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) Width (W) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) A B Weight Exit Type Nominal Length Frame Size (H x L) Order information No. Items Per Standard Package 6 Specifications by lamp and line voltage Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil S62 480 5% HX-HPF 180C Dry film 7 Mfd 300 100°C (212°F) HPS150-3A 86635 Supply Current Frequency No. Items Per Sales Unit 1 Safety and performance Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics 60 Hz Order information Lamp S68 50W High Pressure Sodium 1 – 70W HPS S62 480V General characteristics Wiring diagram HID W-(H)-87094-87152 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 1.0 B 3.0 Weight 3.40 lbs Exit Type Side Nominal Length 2.7 in (69.85 mm) Frame Size (H x L) 2.813 in x 3.939 in Electrical characteristics Supply Current Frequency Type Distributor Kit High Pressure Sodium T5 Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 86456 – GES7048TLC3D-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 87152 – GES50MLTLC3D-5 Quick Reference Guides gelighting.com High Pressure Sodium High Pressure Sodium For 50 – 150W High Pressure Sodium HID Lamps For 50 – 150W High Pressure Sodium HID Lamps High Pressure Sodium 1 – 100W HPS S54 480V General characteristics Dimensions General characteristics Wiring diagram HID W-(F)-87068-86667 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 3.0 Weight 6.20 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Magnetic – Core and Coil S55 480 5% HX-HPF 180C Dry film 10 Mfd 280 100°C (212°F) HPS150-3A 86635 Wiring diagram HID W-(E)-87087-86711-86876 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.0 B 4.0 Weight 8.70 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Electrical characteristics Electrical characteristics Supply Current Frequency 60 Hz 60 Hz Order information Order information Type Distributor Kit No. Items Per Sales Unit 1 Type Distributor Kit No. Items Per Standard Package 6 480 135 0.30 A 1 1.11 0.54 A 0.24 A 119V 384V 90 -22 / -30 2 C cUL Listed No. Items Per Standard Package 6 250W Quartz Metal Halide Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed T12 Fluorescent Ballasts Lamp S55 150W High Pressure Sodium Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Sales Unit 1 Specifications by lamp and line voltage Specifications by lamp and line voltage Safety and performance Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info T5 Fluorescent Ballasts Magnetic – Core and Coil S54 480 5% HX-HPF 180C Dry film 10 Mfd 280 100°C (212°F) HPS150-3A Supply Current Frequency 150W High Pressure Sodium High Pressure Sodium 1 – 150W HPS S55 480V Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Lamp S54 100W High Pressure Sodium • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 87087 – GES15048TLC3D-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 87068 – GES10048TLC3D-5 Quick Reference Guides gelighting.com 480 188 0.40 A 1 1.33 0.73 A 0.31 A 114V 384V 90 -22 / -30 3 F UL Listed Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 87094 – GES150MLTLC3D-5 High Pressure Sodium 1 – 150W HPS S55 Quad (120/208/240/277V) General characteristics Dimensions Magnetic – Core and Coil S55 120/208/240/277 10% HX-HPF 180C Dry film 14 Mfd 280 100°C (212°F) HPS150-3A Wiring diagram HID W-(H)-87094-87152 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.0 B 4.0 Weight 7.60 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Compact Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics Supply Current Frequency 60 Hz Order information No. Items Per Sales Unit 1 HID Electronic Ballasts Type Distributor Kit No. Items Per Standard Package 6 Specifications by lamp and line voltage Lamp S55 150W High Pressure Sodium 250W Quartz Metal Halide Specifications by line voltage Safety and performance 164 120 175 1.60 A 1 1.43 2.72 A 1.64 A 115V 96V 90 -22 / -30 10 B cUL Listed 208 175 0.90 A 1 1.43 1.53 A 0.88 A 115V 166V 90 -22 / -30 5 B 240 175 0.80 A 1 1.43 1.34 A 0.76 A 115V 192V 90 -22 / -30 5 B 277 175 0.70 A 1 1.43 1.16 A 0.65 A 115V 222V 90 -22 / -30 5 B UL Listed See page 195 for warranty information. See page 195 for warranty information. 165 HID Electromagnetic Ballasts System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise High Pressure Sodium High Pressure Sodium For 250 – 1000W High Pressure Sodium HID Lamps For 250 – 1000W High Pressure Sodium HID Lamps High Pressure Sodium 1 – 250W HPS S50 5-Tap (120/208/240/277/480V) General characteristics Dimensions Magnetic – Core and Coil S50 120/208/240/277/480 10% CWA 180C Oil filled 35 Mfd 240 100°C (212°F) HPS400-3A 60 Hz Order information Type Distributor Kit No. Items Per Sales Unit 1 No. Items Per Standard Package 3 Safety and performance cUL Listed 208 292 1.50 A 1 0.86 1.50 A 0.93 A 186V 166V 90 -22 / -30 5 C 240 292 1.30 A 1 0.86 1.30 A 0.81 A 186V 192V 90 -22 / -30 4 B 277 292 1.10 A 1 0.86 1.10 A 0.70 A 186V 222V 90 -22 / -30 4 B 480 292 0.60 A 1 0.86 0.60 A 0.40 A 186V 384V 90 -22 / -30 4 B 1 – 250W HPS S50 Quad (120/208/240/277V) General characteristics Dimensions No. Items Per Standard Package 3 Specifications by line voltage 120 472 4.00 A 1 0.85 4.00 A 2.87 A 191V 96V 90 -22 / -30 15 C System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise cUL Listed 208 472 2.20 A 1 0.85 2.20 A 1.66 A 191V 166V 90 -22 / -30 8 C 240 472 2.00 A 1 0.85 2.00 A 1.44 A 191V 192V 90 -22 / -30 8 C 277 472 1.70 A 1 0.85 1.70 A 1.25 A 191V 222V 90 -22 / -30 5 C 480 472 1.00 A 1 0.85 1.00 A 0.72 A 191V 384V 90 -22 / -30 5 C UL Listed • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 87164 – GES400MLTAC4-5 High Pressure Sodium 1 – 400W HPS S51 Quad (120/208/240/277V) General characteristics Wiring diagram HID W-(A)-87056-87121-87164 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 11.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 4.75 in Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil S51 120/208/240/277 10% CWA 180C Oil filled 55 Mfd 240 100°C (212°F) HPS400-3A 86641 Wiring diagram HID W-(A)-87056-87121-87164 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 13.60 lbs Exit Type Side Nominal Length 4.2 in (107.95 mm) Frame Size (H x L) 4.25 in x 4.75 in Electrical characteristics Electrical characteristics Supply Current Frequency 60 Hz 60 Hz Order information No. Items Per Sales Unit 1 Type Distributor Kit No. Items Per Standard Package 3 Lamp S51 400W High Pressure Sodium Specifications by line voltage 208 303 1.50 A 1 0.83 1.50 A 0.86 A 186V 166V 90 -22 / -30 5 A 240 303 1.30 A 1 0.83 1.30 A 0.75 A 186V 192V 90 -22 / -30 4 A 277 303 1.10 A 1 0.83 1.10 A 0.63 A 186V 222V 90 -22 / -30 4 A Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed See page 195 for warranty information. cUL Listed See page 195 for warranty information. 120 443 3.80 A 1 0.90 3.80 A 1.78 A 186V 96V 90 -22 / -30 15 D 208 443 2.20 A 1 0.90 2.20 A 1.03 A 186V 166V 90 -22 / -30 8 D 240 443 1.90 A 1 0.90 1.90 A 0.90 A 186V 192V 90 -22 / -30 8 D 277 443 1.60 A 1 0.90 1.60 A 0.77 A 186V 222V 90 -22 / -30 5 D UL Listed 167 HID Electromagnetic Ballasts cUL Listed 120 303 2.60 A 1 0.83 2.60 A 1.50 A 186V 96V 90 -22 / -30 8 A No. Items Per Standard Package 3 Specifications by lamp and line voltage Specifications by lamp and line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Sales Unit 1 HID Electronic Ballasts Order information Type Distributor Kit 166 No. Items Per Sales Unit 1 Compact Fluorescent Ballasts Magnetic – Core and Coil S50 120/208/240/277 10% CWA 180C Oil filled 35 Mfd 240 100°C (212°F) HPS400-3A Supply Current Frequency Safety and performance Order information Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) High Pressure Sodium Lamp S50 250W High Pressure Sodium 60 Hz Type Distributor Kit Safety and performance UL Listed 87121 – GES250MLTAC4-5 Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics Wiring diagram HID W-(B)-87214-87215-87218 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 15.00 lbs Exit Type Side Nominal Length 4.2 in (107.95 mm) Frame Size (H x L) 4.25 in x 4.75 in Lead lengths Orange Violet and Black Violet/White Black/Yellow T12 Fluorescent Ballasts System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Magnetic – Core and Coil S51 120/208/240/277/480 10% CWA 180C Oil filled 55 Mfd 240 100°C (212°F) HPS400-3A 86641 Supply Current Frequency Lamp S51 400W High Pressure Sodium Specifications by line voltage 120 292 2.50 A 1 0.86 2.50 A 1.59 A 186V 96V 90 -22 / -30 8 C Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Specifications by lamp and line voltage Specifications by lamp and line voltage Lamp S50 250W High Pressure Sodium 1 – 400W HPS S51 5-Tap (120/208/240/277/480V) General characteristics Wiring diagram HID W(B)-87214-87215-87218 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.0 B 4.0 Weight 12.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 4.75 in Lead lengths Orange Violet and Black Violet/White Black/Yellow Electrical characteristics Supply Current Frequency High Pressure Sodium T5 Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap 87215 – GES400ML5AC4-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap 87214 – GES250ML5AC4-5 Quick Reference Guides gelighting.com High Pressure Sodium High Pressure Sodium For 250 – 1000W High Pressure Sodium HID Lamps For 250 – 1000W High Pressure Sodium HID Lamps High Pressure Sodium 1 – 400W HPS S51 480V in smaller frame Dimensions General characteristics Wiring diagram HID W-(D)-87048-87198-46936 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.25 in (133.35 mm) Width (W) 1.25 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 2.3 B 4.1 Weight 15.00 lbs Exit Type Side Nominal Length 4.2 in (107.95 mm) Frame Size (H x L) 4.25 in x 4.75 in Electrical characteristics No. Items Per Sales Unit 1 cUL Listed Specifications by line voltage High Pressure Sodium 1 – 1000W HPS S52 480V cUL Listed 208 1,102 5.50 A 1 0.91 5.50 A 3.40 A 435V 166V 90 -22 / -30 15 D 240 1,102 4.70 A 1 0.91 4.70 A 2.90 A 435V 192V 90 -22 / -30 10 D 277 1,102 4.10 A 1 0.91 4.10 A 2.60 A 435V 222V 90 -22 / -30 10 D UL Listed • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • Quad ballast (120, 208, 240, 277) 87056 – GES1000MLTAC5-5 High Pressure Sodium 1 – 1000W HPS S52 Quad (120/208/240/277V) General characteristics Dimensions Magnetic – Core and Coil S52 480 10% CWA 180C Oil filled 26 Mfd 525 100°C (212°F) HPS24 General characteristics Wiring diagram HID W-(D)-87048-87198-46936 – see example on page 181 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 7.75 in (196.85 mm) Width (W) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 3.8 B 6.0 Weight 28.00 lbs Exit Type Side Nominal Length 4.7 in (120.65 mm) Frame Size (H x L) 4.25 in x 6.00 in Electrical characteristics Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil S52 120/208/240/277 10% CWA 180C Oil filled 26 Mfd 525 100°C (212°F) HPS1000-4B Wiring diagram HID W-(A)-87056-87121-87164 – see example on page 181 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 7.75 in (196.85 mm) Width (W) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 4.0 B 6.0 Weight 28.00 lbs Exit Type Side Nominal Length 4.7 in (120.65 mm) Frame Size (H x L) 4.25 in x 6.00 in Compact Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info 480 1,102 2.40 A 1 0.91 2.40 A 1.80 A 435V 384V 90 -22 / -30 8 D Electrical characteristics Supply Current Frequency 60 Hz Supply Current Frequency Order information Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 120 1,102 9.50 A 1 0.91 9.50 A 5.75 A 435V 96V 90 -22 / -30 20 D System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed 87048 – GES100048TAC5-5 60 Hz Order information No. Items Per Sales Unit 1 No. Items Per Standard Package 2 Type Distributor Kit Specifications by lamp and line voltage Lamp S52 1000W High Pressure Sodium 480 1,129 2.13 A 1 0.89 2.13 A 1.80 A 433V 384V 90 -22 / -30 8 D Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed See page 195 for warranty information. cUL Listed See page 195 for warranty information. 120 1,100 9.50 A 1 0.91 9.50 A 5.00 A 430V 96V 208 1,100 5.50 A 1 0.91 5.50 A 3.00 A 430V 166V 240 1,100 4.80 A 1 0.91 4.80 A 2.60 A 430V 192V 277 1,100 4.20 A 1 0.91 4.20 A 2.20 A 430V 222V -22 / -30 20 A -22 / -30 15 A -22 / -30 10 A -22 / -30 10 A UL Listed 169 HID Electromagnetic Ballasts cUL Listed No. Items Per Standard Package 2 Specifications by lamp and line voltage Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Sales Unit 1 HID Electronic Ballasts Type Distributor Kit 168 No. Items Per Standard Package 2 T12 Fluorescent Ballasts 480 475 1.00 A 1 0.84 1.00 A 0.60 A 195V 384V 90 -22 / -30 5 D System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise No. Items Per Sales Unit 1 Wiring diagram HID W-(B)-87214-87215-87218 – see example on page 181 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 7.75 in (196.85 mm) Width (W) 2.75 in (69.85 mm) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 4.0 B 6.0 Weight 28.00 lbs Exit Type Side Nominal Length 4.7 in (120.65 mm) Frame Size (H x L) 4.25 in x 6.00 in Lead lengths Orange Violet and Black Violet/White Black/Yellow Specifications by lamp and line voltage Lamp S52 1000W High Pressure Sodium Specifications by line voltage Safety and performance 60 Hz Type Distributor Kit No. Items Per Standard Package 3 Specifications by lamp and line voltage Lamp S52 1000W High Pressure Sodium Electrical characteristics Order information Order information Safety and performance Magnetic – Core and Coil S52 120/208/240/277/480 10% CWA 180C Oil filled 26 Mfd 525 100°C (212°F) HPS1000-4B Supply Current Frequency 60 Hz Type Distributor Kit Lamp S51 400W High Pressure Sodium Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info T5 Fluorescent Ballasts Magnetic – Core and Coil S51 480 10% CWA 180C Oil filled 55 Mfd 240 100°C (212°F) HPS400-3A Supply Current Frequency High Pressure Sodium 1 – 1000W HPS S52 5-Tap (120/208/240/277/480V) General characteristics Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap 87218 – GES1000ML5AC5-5 T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement 87198 – GES40048TAC4-5 Quick Reference Guides gelighting.com High Intensity Discharge Lamp Ballast Kits 71701 – GEM175ML5AC3-55 1 – 175W MH M57 or H39 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) General characteristics • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap Electrical characteristics Supply Current Frequency 60 Hz Order information Type Distributor Kit No. Items Per Sales Unit 1 No. Items Per Standard Package 6 Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.3 in (133.35 mm) Width (W) 1.3 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.3 in (6.35 mm) A 3.0 B 4.0 Weight 8.00 lbs Exit Type Side Nominal Length 3.2 in (82.55 mm) Frame Size (H x L) 2.813 in x 3.939 in Lead Lengths Orange and Red Violet and Black Black/Yellow Violet/White Yellow Safety and performance cUL Listed 208 202 1.00 A 1 0.87 1.00 A 0.37 A 307V 166V 90 -22 / -30 3 C 240 202 0.90 A 1 0.87 0.90 A 0.32 A 307V 192V 90 -22 / -30 3 C 277 202 0.80 A 1 0.87 0.80 A 0.28 A 307V 222V 90 -22 / -30 2 C 480 202 0.40 A 1 0.87 0.40 A 0.21 A 307V 384V 90 -22 / -30 1.5 C General characteristics 400W Mercury • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap Dimensions Electrical characteristics 60 Hz No. Items Per Standard Package 6 175W Quartz Metal Halide Safety and performance 170 cUL Listed 208 436 2.10 A 240 436 1.90 A 277 436 1.60 A 480 436 0.90 A 0.92 3.70 A 2.19 A 300V 96V 90 -22 / -30 10 E 0.92 2.10 A 1.31 A 300V 166V 90 -22 / -30 8 E 0.92 1.90 A 1.11 A 300V 192V 90 -22 / -30 5 E 0.92 1.60 A 1.00 A 300V 222V 90 -22 / -30 5 E 0.92 0.90 A 0.60 A 300V 384V 90 -22 / -30 5 E cUL Listed UL Listed High Intensity Discharge Lamp Ballast Kits 1 – 1000W MH M47 or H36 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Magnetic – Core and Coil M47, H36 120/208/240/277/480 10% CWA 180C Oil filled 24 Mfd 400 100°C (212°F) Electrical characteristics Supply Current Frequency 60 Hz Order information Type Distributor Kit No. Items Per Sales Unit 1 No. Items Per Standard Package 2 Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 7.8 in (196.85 mm) Width (W) 2.8 in (69.85 mm) Height (H) Mounting dimensions Mount Length (M) 6.1 in (154.94 mm) Mount Width (X or F) Mount Slots (MS) 0.3 in (6.35 mm) A 3.0 B 5.0 Weight 21.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 6.00 in Lead Lengths Orange and Red Violet and Black Black/Yellow Violet/White Yellow Specifications by lamp and line voltage 208 280 1.40 A 1 0.89 1.60 A 1.00 A 290V 166V 90 -22 / -30 5 B 240 280 1.25 A 1 0.89 1.30 A 0.80 A 290V 192V 90 -22 / -30 4 B 277 280 1.10 A 1 0.89 1.20 A 0.70 A 290V 222V 90 -22 / -30 3 C 480 280 0.65 A 1 0.89 0.70 A 0.50 A 290V 384V 90 -22 / -30 2 C 1000W Mercury Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed See page 195 for warranty information. cUL Listed See page 195 for warranty information. 120 1103 9.30 A 1 0.91 9.30 A 6.34 A 445V 96V 90 -22 / -30 20 E 208 1103 5.40 A 1 0.91 5.40 A 3.71 A 445V 166V 90 -22 / -30 15 C 240 1103 4.70 A 1 0.91 4.70 A 3.20 A 445V 192V 90 -22 / -30 10 C 277 1103 4.10 A 1 0.91 4.10 A 2.79 A 445V 222V 90 -22 / -30 10 C 480 1103 2.40 A 1 0.91 2.40 A 1.65 A 445V 384V 90 -22 / -30 10 D UL Listed 171 HID Electromagnetic Ballasts 250W Mercury 120 436 3.70 A 71704 – GEM1000ML5AC4-55 Lamp M47, H33 1000W Quartz Metal Halide Specifications by line voltage 120 280 2.50 A 1 0.89 2.60 A 1.50 A 290V 96V 90 -22 / -30 8 B System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise General characteristics Wiring diagram HID W-(H)-86587-87074 – see example on page 182 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.3 in (133.35 mm) Width (W) 1.3 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.3 in (6.35 mm) A 3.0 B 4.3 Weight 9.00 lbs Exit Type Side Nominal Length 3.2 in (82.55 mm) Frame Size (H x L) 2.813 in x 3.939 in Lead Lengths Orange and Red Violet and Black Black/Yellow Violet/White Yellow Specifications by lamp and line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Specifications by line voltage HID Electronic Ballasts Order information Lamp M58, H37 250W Quartz Metal Halide No. Items Per Standard Package 3 Compact Fluorescent Ballasts Magnetic – Core and Coil M58, H37 120/208/240/277/480 10% CWA 180C Oil filled 15 Mfd 400 100°C (212°F) No. Items Per Sales Unit 1 No. Items Per Sales Unit 1 Sign Ballasts 1 – 250W MH M58 or H37 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) Type Distributor Kit Order information Safety and performance High Intensity Discharge Lamp Ballast Kits Supply Current Frequency 60 Hz Type Distributor Kit 400W Quartz Metal Halide UL Listed 71702 – GEM250ML5AC3-55 Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183 Case dimensions – Ref Drawing PC1 – see page 185 Length (L) 5.3 in (133.35 mm) Width (W) 1.3 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.3 in (6.35 mm) A 2.0 B 4.0 Weight 12.50 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 4.75 in Lead Lengths Orange and Red Violet and Black Black/Yellow Violet/White Yellow T12 Fluorescent Ballasts System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Magnetic – Core and Coil M59, H33 120/208/240/277/480 10% CWA 180C Oil filled 24 Mfd 400 100°C (212°F) Supply Current Frequency Lamp M59, H33 360W Quartz Metal Halide Specifications by line voltage 120 202 1.70 A 1 0.87 1.70 A 0.60 A 307V 96V 90 -22 / -30 5 D Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Specifications by lamp and line voltage Specifications by lamp and line voltage Lamp M57, H39, M109 1 – 400W MH M59 or H33 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap T5 Fluorescent Ballasts Magnetic – Core and Coil M57, H38, M109 120/208/240/277/480 10% CWA 180C Oil filled 10 Mfd 400 100°C (212°F) High Intensity Discharge Lamp Ballast Kits General characteristics Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info 71703 – GEM400ML5AC4-55 T8 Fluorescent Ballasts High Intensity Discharge Lamp Ballast Kits High Intensity Discharge Lamp Ballast Kits Quick Reference Guides gelighting.com High Intensity Discharge Lamp Ballast Kits High Intensity Discharge Lamp Ballast Kits High Intensity Discharge Lamp Ballast Kits 1 – 100W HPS S54 Quad (120/208/240/277V) Lamp & Ballast Kit (-55) General characteristics Dimensions Magnetic – Core and Coil S54 120/208/240/277 5% HX-HPF 180C Dry Film 10 Mfd 280 100°C (212°F) HPS100-3A 86884 Magnetic – Core and Coil S51 120/208/240/277/480 10% CWA 180C Oil Filled 55 Mfd 240 100°C (212°F) HPS1000-4B Supply Current Frequency Order information 60 Hz Order information No. Items Per Sales Unit 1 No. Items Per Standard Package 6 Type Distributor Kit Specifications by lamp and line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise cUL Listed No. Items Per Standard Package 3 208 123 1.30 A 1 1.22 1.27 A 0.43 A 119V 166V 90 -22 / -30 5 B 240 123 1.10 A 1 1.22 1.13 A 0.36 A 119V 192V 90 -22 / -30 5 B Lamp S51 400W High Pressure Sodium 277 123 0.90 A 1 1.22 0.94 A 0.31 A 119V 222V 90 -22 / -30 3 B Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed cUL Listed 120 472 4.00 A 1 0.85 4.00 A 2.87 A 191V 96V 90 -22 / -30 15 C 208 472 2.20 A 1 0.85 2.20 A 1.66 A 191V 166V 90 -22 / -30 8 C 240 472 2.00 A 1 0.85 2.00 A 1.44 A 191V 192V 90 -22 / -30 8 C 277 472 1.70 A 1 0.85 1.70 A 1.25 A 191V 222V 90 -22 / -30 5 C T12 Fluorescent Ballasts 120 123 2.20 A 1 1.22 2.18 A 0.74 A 119V 96V 90 -22 / -30 8 B No. Items Per Sales Unit 1 Wiring diagram HID W-(B)-87214-87215-87218 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.3 in (133.35 mm) Width (W) 1.3 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.3 in (6.35 mm) A 2.0 B 4.0 Weight 15.00 lbs Exit Type Side Nominal Length 4.2 in (107.95 mm) Frame Size (H x L) 4.25 in x 4.75 in Lead Lengths Orange and Red Violet and Black Black/Yellow Violet/White Yellow Specifications by lamp and line voltage Specifications by line voltage Safety and performance Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Electrical characteristics 60 Hz Type Distributor Kit 150W High Pressure Sodium 1 – 400W HPS S51 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) General characteristics Wiring diagram HID W-(K)-87212-87213 – see example on page 183 Case dimensions – Ref Drawing PC3 – see page 185 Length (L) 5.3 in (133.35 mm) Width (W) 1.3 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.3 in (6.35 mm) A 2.0 B 4.0 Weight 6.20 lbs Exit Type Side Nominal Length 2.7 in (68.58 mm) Frame Size (H x L) 2.813 in x 3.939 in Electrical characteristics Supply Current Frequency Lamp S54 100W High Pressure Sodium High Intensity Discharge Lamp Ballast Kits T5 Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap 71707 – GES400ML5AC4-55 480 472 1.00 A 1 0.85 1.00 A 0.72 A 191V 384V 90 -22 / -30 5 C UL Listed Sign Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap 71706 – GES250ML5AC4-55 High Intensity Discharge Lamp Ballast Kits 1 – 250W HPS S50 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55) General characteristics Dimensions Magnetic – Core and Coil S50 120/208/240/277/480 10% CWA 180C Oil Filled 35 Mfd 240 100°C (212°F) HPS400-3A 86641 Electrical characteristics Supply Current Frequency 60 Hz Order information No. Items Per Sales Unit 1 No. Items Per Standard Package 3 HID Electronic Ballasts Type Distributor Kit Wiring diagram HID W-(B)-87214-87215-87218 – see example on page 181 Case dimensions – Ref Drawing PC2 – see page 185 Length (L) 5.3 in (133.35 mm) Width (W) 1.3 in (31.75 mm) Mounting dimensions Mount Length (M) 4.6 in (116.84 mm) Mount Width (X or F) Mount Slots (MS) 0.3 in (6.35 mm) A 2.0 B 4.0 Weight 12.00 lbs Exit Type Side Nominal Length 3.7 in (95.25 mm) Frame Size (H x L) 4.25 in x 4.75 in Lead Lengths Orange and Red Violet and Black Black/Yellow Violet/White Yellow Compact Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating GE Igniter Sound Rating Additional Info Specifications by lamp and line voltage Lamp S50 250W High Pressure Sodium Specifications by line voltage 172 cUL Listed 120 292 2.50 A 1 0.86 2.50 A 1.59 A 186V 96V 90 -22 / -30 8 C 208 292 1.50 A 1 0.86 1.50 A 0.93 A 186V 166V 90 -22 / -30 5 C 240 292 1.30 A 1 0.86 1.30 A 0.81 A 186V 192V 90 -22 / -30 4 B 277 292 1.10 A 1 0.86 1.10 A 0.70 A 186V 222V 90 -22 / -30 4 B 480 292 0.60 A 1 0.86 0.60 A 0.40 A 186V 384V 90 -22 / -30 4 B UL Listed See page 195 for warranty information. See page 195 for warranty information. 173 HID Electromagnetic Ballasts System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance T8 Fluorescent Ballasts • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity • Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement • 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap 71705 – GES100MLTLC3D-55 Quick Reference Guides gelighting.com Enclosed and Potted Metal Halide Enclosed and Potted Metal Halide • For applications requiring quieter or cooler operation than provided by standard coil and coil ballasts • Excellent sound-deadening and heat transfer qualities 86576 – 11210277CTC000C General characteristics General characteristics Dimensions Magnetic – F-Can M98, M143 100°C (212°F) Thermally Protected Electrical characteristics 60 Hz Order information Type Standard Pack No. Items Per Sales Unit 1 11.8 in (298.45 mm) 3.2 in (80.96 mm) 2.6 in (66.67 mm) 11.1 in (282.97 mm) 2.0 in (50.80 mm) 0.2 in (5.95 mm) 11.00 lbs Side 20 ft 18 AWG Safety and performance cUL Listed Type Standard Pack 100W Quartz Metal Halide UL Listed Wiring diagram HID H34 – see example on page 180 Case dimensions – Ref Drawing FCAN1 – see page 184 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead Lengths Black and White Red Black/Yellow B (25-30 decibels) Thermally Protected 60 Hz Order information 11.8 in (298.45 mm) 3.2 in (80.96 mm) 2.6 in (66.67 mm) 11.1 in (282.97 mm) 2.0 in (50.80 mm) 0.2 in (5.95 mm) 11.00 lbs Side 20 ft 18 AWG Magnetic – F-Can M57, H39 120/277 10% CWA 90C Wiring diagram HID H34 – see example on page 180 Case dimensions – Ref Drawing FCAN2 – see page 184 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead Lengths Black and White Red Black/Yellow 100°C (212°F) B (25-30 decibels) Thermally Protected Electrical characteristics Supply Current Frequency 60 Hz Order information Type Standard Pack No. Items Per Standard Package 4 No. Items Per Sales Unit 1 14.3 in (363.72 mm) 3.2 in (80.96 mm) 2.6 in (66.67 mm) 13.8 in (349.25 mm) 2.0 in (50.80 mm) 0.2 in (5.84 mm) 14.00 lbs Side No. Items Per Standard Package 2 Specifications by lamp and line voltage Lamp M57, H39 175W Ceramic Metal Halide Specifications by line voltage 120 90 0.78 A 1 0.78 2.00 A 0.60 A 250V 96V 90 -22 / -30 6 Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Sound Rating Additional Info 277 90 0.35 A 1 0.78 0.90 A 0.27 A 250V 222V 90 -22 / -30 3 150W Quartz Metal Halide 175W Mercury Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed See page 195 for warranty information. cUL Listed See page 195 for warranty information. 120 205 1.75 a 1 0.85 277 205 0.75 A 1 0.85 300V 96V 90 -22 / -30 5 300V 222V 90 -22 / -30 3 UL Listed 175 HID Electromagnetic Ballasts 174 Enclosed and Potted Metal Halide General characteristics Specifications by lamp and line voltage cUL Listed • For applications requiring quieter or cooler operation than provided by standard coil and coil ballasts • Excellent sound-deadening and heat transfer qualities 86563 – 1110245SCTC000I HID Electronic Ballasts No. Items Per Sales Unit 1 Safety and performance UL Listed Compact Fluorescent Ballasts Magnetic – F-Can M98 120/277 5% HX-HPF 90C Electrical characteristics 70W Quartz Metal Halide cUL Listed 277 125 1.10 A 1 0.80 1.10 A 0.50 A 250V 222V 90 -22 / -30 4 1 – 175W M57 120/277 Enclosed and Potted Dimensions System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 120 125 2.20 A 1 0.80 2.20 A 1.10 A 250V 96V 90 -22 / -30 8 System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Sign Ballasts • For applications requiring quieter or cooler operation than provided by standard coil and coil ballasts • Excellent sound-deadening and heat transfer qualities General characteristics Lamp M98 70W Ceramic Metal Halide No. Items Per Standard Package 4 Specifications by line voltage Safety and performance 1 – 70W M98 120/277 Enclosed and Potted Type Standard Pack No. Items Per Sales Unit 1 11.1 in (282.97 mm) 2.0 in (50.80 mm) 0.2 in (5.95 mm) 11.00 lbs Side 20 ft 18 AWG Specifications by lamp and line voltage Lamp M90 100W Ceramic Metal Halide 277 90 0.35 A 1 0.78 0.90 A 0.27 A 250V 222V 90 -22 / -30 3 Enclosed and Potted Metal Halide Supply Current Frequency 60 Hz Order information No. Items Per Standard Package 4 86578 – 11210506CTC000C Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Sound Rating Additional Info 100°C (212°F) B (25-30 decibels) Thermally Protected 11.8 in (298.45 mm) 3.2 in (80.96 mm) 2.6 in (66.67 mm) T12 Fluorescent Ballasts 70W Quartz Metal Halide System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Wiring diagram HID H34 – see example on page 180 Case dimensions – Ref Drawing FCAN1 – see page 184 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead Lengths Black and White Red Black/Yellow Electrical characteristics Specifications by line voltage 120 90 0.78 A 1 0.78 2.00 A 0.60 A 250V 66V 90 -22 / -30 6 Magnetic – F-Can M90 120/277 5% HX-HPF 90C Supply Current Frequency Specifications by lamp and line voltage Lamp M98, M143 70W Ceramic Metal Halide Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Sound Rating Additional Info T5 Fluorescent Ballasts Wiring diagram HID H34 – see example on page 180 Case dimensions – Ref Drawing FCAN1 – see page 184 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead Lengths Black and White Red Black/Yellow 5% HX-HPF 90C Supply Current Frequency Enclosed and Potted Metal Halide 1 – 100W M90 120/277 Enclosed and Potted 1 – 70W M85 120/277 Enclosed and Potted Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Sound Rating Additional Info • For applications requiring quieter or cooler operation than provided by standard coil and coil ballasts • Excellent sound-deadening and heat transfer qualities 86574 – 11210239CTC000I T8 Fluorescent Ballasts Enclosed and Potted Metal Halide Quick Reference Guides gelighting.com Enclosed and Potted Metal Halide Enclosed and Potted Metal Halide • For applications requiring quieter or cooler operation than provided by standard coil and coil ballasts • Excellent sound-deadening and heat transfer qualities 86564 – 1110246CTC000C 1 – 250W M58 120/277 Enclosed and Potted Magnetic – F-Can M58, H37 120/277 10% CWA 90C Electrical characteristics 60 Hz Order information Type Standard Pack No. Items Per Sales Unit 1 General characteristics 16.8 in (425.45 mm) 3.2 in (81.02 mm) 2.7 in (69.59 mm) 16.1 in (409.57 mm) 2.0 in (50.80 mm) 0.2 in (5.94 mm) 17.50 lbs Side 250W Mercury Safety and performance 60 Hz Order information No. Items Per Standard Package 2 Type Standard Pack No. Items Per Sales Unit 1 13.8 in (349.25 mm) 2.0 in (50.80 mm) 0.2 in (5.84 mm) 14.00 lbs Side No. Items Per Standard Package 4 Specifications by lamp and line voltage 120 295 2.50 A 1 0.85 277 295 1.10 A 1 0.85 280V 96V 90 -22 / -30 8 280V 222V 90 -22 / -30 4 Lamp M59, H33 360W Quartz Metal Halide 400W Quartz Metal Halide 400W Mercury cUL Listed 100°C (212°F) C (31-36 decibels) Thermally Protected 14.3 in (363.72 mm) 3.2 in (80.96 mm) 2.6 in (66.67 mm) Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Safety and performance UL Listed cUL Listed 120 460 3.90 A 1 0.87 277 460 1.70 A 1 0.87 300V 96V 300V 222V -22 / -30 10 -22 / -30 5 T12 Fluorescent Ballasts 175W Quartz Metal Halide Wiring diagram HID H36 – see example on page 180 Case dimensions – Ref Drawing FCAN2 – see page 184 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead Lengths Black and White Red Black/Yellow Electrical characteristics Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Magnetic – F-Can M59, H33 120/277 10% CWA 90C Supply Current Frequency Specifications by lamp and line voltage Lamp M58, H37 250W Quartz Metal Halide Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Sound Rating Additional Info T5 Fluorescent Ballasts Wiring diagram HID H34 – see example on page 180 Case dimensions – Ref Drawing FCAN3 – see page 184 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead Lengths Black and White Red Black/Yellow 100°C (212°F) C (31-36 decibels) Thermally Protected Supply Current Frequency Enclosed and Potted Metal Halide 1 – 400W M59 120/277 Enclosed and Potted Dimensions General characteristics Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Sound Rating Additional Info • For applications requiring quieter or cooler operation than provided by standard coil and coil ballasts • Excellent sound-deadening and heat transfer qualities 80728 – 1111-247SCTC000I T8 Fluorescent Ballasts Enclosed and Potted Metal Halide UL Listed Sign Ballasts • For applications requiring quieter or cooler operation than provided by standard coil and coil ballasts • Excellent sound-deadening and heat transfer qualities 42670 – 1110-247SC-TC Enclosed and Potted Metal Halide Quick Reference Guides gelighting.com 1 – 400W M59 120/277 Enclosed and Potted F-Can General characteristics Dimensions Magnetic – F-Can M59, H33 120/277 10% CWA 90C Wiring diagram HID H34 – see example on page 180 Case dimensions – Ref Drawing FCAN4 – see page 184 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead Lengths Black and White Red Black/Yellow 100°C (212°F) C (31-36 decibels) Thermally Protected Electrical characteristics Supply Current Frequency 60 Hz Order information No. Items Per Sales Unit 1 18.6 in (473.07 mm) 2.0 in (50.80 mm) 0.2 in (5.95 mm) 23.00 lbs Side No. Items Per Standard Package 2 HID Electronic Ballasts Type Standard Pack 19.3 in (488.95 mm) 3.2 in (80.96 mm) 2.6 in (66.67 mm) Compact Fluorescent Ballasts Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Sound Rating Additional Info Specifications by lamp and line voltage Lamp M59, H39 360W Quartz Metal Halide 400W Quartz Metal Halide 400W Mercury Specifications by line voltage Safety and performance 176 cUL Listed 120 455 3.90 A 1 0.88 3.90 A 2.50 A 300V 66V 90 -22 / -30 10 C 277 455 1.70 A 1 0.88 1.70 A 1.00 A 300V 222V 90 -22 / -30 5 C UL Listed See page 195 for warranty information. See page 195 for warranty information. 177 HID Electromagnetic Ballasts System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise F-Can and Post Mount High Pressure Sodium F-Can and Post Mount High Pressure Sodium • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity 86605 – 1233142U000I • Magnetic ballast construction ideal for a wide variety of lighting applications • Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity 86606 – 1233154U000I F-Can and Post Mount High Pressure Sodium 1 – 70W S62 120 Reactor-NPF 1 – 150W S55 120 Reactor-NPF General characteristics Dimensions Magnetic – Core and Coil S62 120 5% R-HPF R-NPF 90C 100°C (212°F) Electrical characteristics Supply Current Frequency 60 Hz Order information Type Standard Pack No. Items Per Sales Unit 1 No. Items Per Standard Package 6 120 83 0.75 A 1 0.84 1.30 A 0.90 A 120V 96V 90 -22 / -30 5 A Electrical characteristics 120 83 1.60 A 1 0.84 2.10 A 2.10 A 120V 96V 80 -22 / -30 8 A Type Standard Pack No. Items Per Sales Unit 1 250W Quartz Metal Halide 0.25 in (6.35 mm) 2.0 3.0 3.50 lbs Side 2.813 in x 3.939 in Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise 120 171 1.50 A 1 1.46 2.40 A 2.20 A 120V 96V 90 -22 / -30 8 A cUL Listed 120 171 3.20 A 1 1.46 4.40 A 4.40 A 120V 96V 80 -22 / -30 15 A UL Listed General characteristics Dimensions 100°C (212°F) Thermally protected Electrical characteristics 60 Hz Order information No. Items Per Standard Package 4 11.75 in (298.45 mm) 3.188 in (80.96 mm) 2.625 in (66.67 mm) 11.14 in (282.97 mm) 2.00 in (50.80 mm) 0.23 in (5.95 mm) Replacement Ignitors for Pulse Start Lamps (MH & HPS) 11.00 lbs Side Other Accessories Description 005-1184-MF 005-1185-MF 005-1422-MF 005-2779-MF 005-3160-MF MH100-3A HPS150-3A HPS400-3A 000-8724 001-2009 004-9177 2BMB1000C Application 10.0 MFD 400V 90C 2.4 MEG 1.50 oval 2.7 ht 15.0 MFD 400V 90C 1.6 MEG 1.75 oval 2.7 ht 48.0 MFD 300V 90C 0.6 MEG 1.75 oval 3.9 ht 24.0 MFD 480V 90C 1.75 oval 3.9 ht 24.0 MFD 360V 90C 1.0 MEG 1.75 oval 3.1 ht Ignitor for MH 30 50 70 100 Ignitor HPS 150 watts or less except 150w-S56 Ignitor HPS 200-400 watts & 150w S56 HIDP Adjustable Mounting Bracket Hardware Kit Splice Box Adjustable Mounting Bracket For 4” HID HID Parts E&P Mounting Bracket Units Per Carton 20 20 20 20 20 20 20 10 100 10 50 50 HID Electronic Ballasts No. Items Per Sales Unit 1 Wiring diagram HID H34 – see example on page 180 Case dimensions – Ref Drawing FCAN1 – see page 184 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) A B Weight Exit Type Nominal Length Frame Size (H x L) Lead lengths White Black Black/Yellow Red Prod Code 88980 88982 89007 89077 89083 86864 86635 86641 47621 86467 86468 86624 Compact Fluorescent Ballasts Magnetic – F-Can S62 120/277 5% HX-HPF 90C HID Accessories HID Accessories Replacement Capacitors 1 – 70W S62 120/277 E & P F-Can built-in starter Type Standard Pack 4.00 in (101.60 mm) 3.30 in (85.09 mm) Sign Ballasts • For applications requiring quieter or cooler operation than provided by standard coil & coil ballasts • Excellent sound-deadening and heat transfer qualities F-Can and Post Mount High Pressure Sodium Supply Current Frequency No. Items Per Standard Package 6 4.00 in (101.60 mm) 0.75 in (19.05 mm) 0.00 in (2.36 mm) UL Listed 86596 – 12210237CTC000I Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Sound Rating Additional Info 60 Hz Order information Safety and performance cUL Listed Thermally protected Wiring diagram HID H1 – see example on page 180 Case dimensions – Ref Drawing 1 – see page 184 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) A B Weight Exit Type Nominal Length Frame Size (H x L) Lead lengths Black Blue White T12 Fluorescent Ballasts Safety and performance 52 Mfd 120 100°C (212°F) Supply Current Frequency Lamp S55 150W High Pressure Sodium Specifications by line voltage System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Magnetic – Core and Coil S55 120 5% R-NPF 180C Specifications by lamp & line voltage Specifications by lamp & line voltage Lamp S62 70W High Pressure Sodium Dimensions Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Sound Rating Additional Info T5 Fluorescent Ballasts Circuit Type Insulation Class Type of Capacitor Capacitance Voltage (MIN) Capacitor Temperature Rating Sound Rating Additional Info General characteristics Wiring diagram HID H1a, HID H1 – see example on page 180 Case dimensions – Ref Drawing 1 – see page 184 Length (L) 4.00 in (101.60 mm) Width (W) 0.75 in (19.05 mm) Height (H) 0.00 in (2.36 mm) Mounting dimensions Bracket Length (BL) 4.00 in (101.60 mm) Mount Length (M) 3.30 in (85.09 mm) Mount Width (X or F) Mount Slots (MS) 0.25 in (6.35 mm) A 1.3 B 2.6 Weight 2.50 lbs Exit Type Side Nominal Length Frame Size (H x L) Lead lengths Black Blue White T8 Fluorescent Ballasts F-Can and Post Mount High Pressure Sodium Ballast Type ANSI Lamp Codes Voltage Line Voltage Regulation (+/-) Specifications by lamp & line voltage Lamp S62 70W High Pressure Sodium Specifications by line voltage Safety and performance 178 120 98 0.87 A 1 0.71 0.87 A 0.60 A 140V 96V 90 -22 / -30 6 cUL Listed 277 98 0.39 A 1 0.71 0.39 A 0.27 A 140V 222V 90 -22 / -30 3 UL Listed See page 195 for warranty information. See page 195 for warranty information. 179 HID Electromagnetic Ballasts System Wattage (W) Nominal Current Ballast Factor Ballast Efficiency Factor Max Input Current Starting Current Open Circuit Voltage Drop Out Voltage Power Factor (>=)% Min. Starting Temp (°F/°C) Fuse Rating UL Bench Top Rise Quick Reference Guides gelighting.com Wiring Diagrams HID Electromagnetic Ballasts HID H1 Wiring Diagrams HID Electromagnetic Ballasts HID H1a HID W-(A)-86959-86984-87008 HID W-(A)-87056-87121-87164 HID W-(B)-87214-87215-87218 HID W-(C)-86655-86698-86741 HID W-(C)-86765-86814 HID W-(D)-86952-86999 HID W-(D)-87048-87198-46936 T8 Fluorescent Ballasts HID W-(A)-46934-86885-86935 Quick Reference Guides gelighting.com Sign Ballasts Compact Fluorescent Ballasts HID H21 See page 195 for warranty information. 181 HID Electromagnetic Ballasts See page 195 for warranty information. HID Electronic Ballasts 180 HID H36 T12 Fluorescent Ballasts HID H6 T5 Fluorescent Ballasts HID H34 Wiring Diagrams HID Electromagnetic Ballasts Wiring Diagrams HID Electromagnetic Ballasts HID W-(E)-87087-86711-86876 HID W-(F)-87068-86667 HID W-(H)-86587-87074 HID W-(K)-86808-87210-87211 HID W-(K)-87212-87213 T8 Fluorescent Ballasts HID W-(E)-86926 Quick Reference Guides gelighting.com T5 Fluorescent Ballasts HID W-(L)-86968 T12 Fluorescent Ballasts HID W-(H)-86824-86847 HID W-(H)-87094-87152 HID W-(J)-86650-86693-86803 Sign Ballasts HID W-(H)-86675-86718 Compact Fluorescent Ballasts HID Electronic Ballasts See page 195 for warranty information. See page 195 for warranty information. 183 HID Electromagnetic Ballasts 182 Case Dimensions HID Electromagnetic Ballasts 1 Case Dimensions HID Electromagnetic Ballasts FCAN1 PC1 Quick Reference Guides gelighting.com PC2 T8 Fluorescent Ballasts A T5 Fluorescent Ballasts T12 Fluorescent Ballasts FCAN2 FCAN3 PC3 Sign Ballasts Compact Fluorescent Ballasts FCAN4 HID Electronic Ballasts See page 195 for warranty information. See page 195 for warranty information. 185 HID Electromagnetic Ballasts 184 Glossary HID Electromagnetic Ballasts 187 HID Electronic Ballasts High-Pressure Sodium (HPS) Lamp HPS lamps are high intensity discharge light sources that produce light by an electrical discharge though sodium vapor operating at relatively high pressures and temperatures. GE trade name is Lucalox®. Hot Restart Time Time it takes for an HID lamp to reach 90% of light output after going from on to off to on. Ignitor An electronic device providing a high voltage pulse to initiate an electrical discharge. Typically, the ignitor is paired with or is a part of the ballast (see STARTER). Infrared Radiation Electromagnetic energy radiated in the wavelength range of about 770 to 1,000,000 nanometers. Energy in this range cannot be seen by the human eye, but can be sensed as heat. Input Voltage Power supply voltage required for proper operation of fluorescent or HID ballast. Input Watts The total power input to the ballast that includes lamp watts and ballast losses. The total power input to the fixture is the input watts to the ballast or ballasts and is the value to be used when calculating cost of energy. More than 90% of the input watts is wattage or power delivered to the lamp load with typical ballast. Instant Start Lamp starting method in which lamps are started by high voltage input with no preheating of lamp filaments. Some rapid start lamps are designed so that they may be instant started. Instant Start Lamp A fluorescent lamp, usually with a single pin at each end, approved to operate on instant start ballasts. The lamp is ignited by a high voltage without any filament heating. Integral A popular term for a compact fluorescent lamp that includes a built-in ballast (see CFL). Kilowatt (kW) The measure of electrical power equal to 1000 watts. Kilowatt Hour (kWh) The standard measure of electrical energy and the typical billing unit used by electrical utilities for electricity use. A 100-watt lamp operated for 10 hours consumes 1000 watt-hours (100 x 10) or one kilowatt-hour. If the utility charges $.10/kWh, then the electricity cost for the 10 hours of operation would be 10 cents (1 kWh x $.10). Laminations Layers of steel, making up the “core” that is surrounded by the coils in a core and coil ballast. Lamp The term used to refer to the complete light-source package, including the inner parts as well as the outer bulb or tube. “Lamp,” of course, is also commonly used to refer to a type of small light fixture such as a table lamp. Lamp Types Filament lamps: Incandescent, Halogen, Halogen-IR. Discharge Lamps: Fluorescent, HID (High Intensity Discharge). HID Lamps: Mercury, HPS (High Pressure Sodium), MH (Metal Halide) and Ceramic Metal Halide. Lamp Watts Input power used to operate lamps. Life (See RATED LAMP LIFE.) Light Radiant energy that can be sensed or seen by the human eye. Visible light is measured in lumens. Light-Emitting Diode (LED) A solid that directly converts electrical impulses into light. Light Loss Factor The product of all factors that contribute to lowering the illumination level including reflector degradation, dirt, lamp depreciation over time, voltage fluctuations, etc. Lumens A measure of the luminous flux or quantity of light emitted by a source. For example, a dinner candle provides about 12 lumens. A 60-watt Soft White incandescent lamp provides about 840 lumens. Compact Fluorescent Ballasts Fluorescent Lamp A high efficiency lamp utilizing an electric discharge through inert gas and low-pressure mercury vapor to produce ultraviolet (UV) energy. The UV excites phosphor materials applied as a thin layer on the inside of a glass tube that makes up the structure of the lamp. The phosphors transform the UV to visible light. Footcandles A unit of illuminance or light falling onto a surface. It stands for the light level on a surface one foot from a standard candle. One footcandle is equal to one lumen per square foot. Four-Pin Compact Fluorescent Lamps A “plug-in” compact fluorescent lamp with four pins in the base to make electrical contact. Frequency Rate of alternation in an AC current. Expressed in cycles per second or Hertz (Hz). Harmonic An integral multiple of the fundamental frequency (60 Hz) that becomes a component of the current. Harmonic Distortion Distortion of an AC waveform caused by multiples of the fundamental frequency (harmonics). Odd triplet harmonics (thirds, ninths, etc.) may result in large currents on the neutral line in a four-wire Wye three-phase system. Hertz (Hz) Unit used to measure frequency of alteration of current or voltage. High Efficiency (Energy-Saving) Electromagnetic Ballast Ballast with core and coils, designed to minimize ballast losses compared to the “standard” ballast. High Intensity Discharge (HID) Lamp A general term for mercury, metal halide (GE ConstantColor® CMH®, Multi-Vapor®, MXR or Arcstream®) and high-pressure sodium (GE Lucalox®) lamps. HID lamps contain compact arc tubes which enclose mercury and various gases with other chemicals and operate at relatively high pressures and temperatures. High Power Factor A ballast whose power factor is corrected to 90% or greater. Sign Ballasts a 100-watt incandescent lamp converts 7% of the electrical energy into light; discharge lamps convert 25% to 40% into light. Efficiency of Ballast The ratio of output power divided by input power. A premium ballast would have an electrical efficiency greater than 90%. The efficiency of a luminaire or fixture is the percentage of the lamp lumens that actually come out of the fixture. Electrical Discharge A condition under which a gas becomes electrically conducive and becomes capable of transmitting current, usually accompanied by the emission of visible and other radiation. An electric spark in air is an example of an electrical discharge, as are a welder’s arc and a lightning bolt. Electrical Testing Laboratory (ETL) Independent testing laboratory that performs tests and certifies performance data. Electrode Any metal terminal emitting or collecting charged particles, typically inside the chamber of a gas discharge lamp. In a fluorescent lamp, the electrodes are typically metal filaments coated with special powders called emission mix. Negatively charged free electrons emitted by one electrode are attracted to the positive electrode (anode), creating an electric current arc. Electromagnetic Ballast (Magnetic Ballast) A ballast used with discharge lamps that consists primarily of transformer-like copper or aluminum windings on a steel or iron core. Also called “core and coil” (see ELECTRONIC BALLASTS). EMI (Electromagnetic Inference) High-frequency electronic ballasts and other electronic devices can produce a small amount of radio waves which can interfere with radio and TV. Federally mandated requirements must be met for EMI levels before an electronic device is considered FCC compliant (FCC is the Federal Communications Commission). Electronic Ballast A short name for a fluorescent high-frequency electronic ballast. Electronic ballasts use solidstate electronic components and typically operate fluorescent lamps at frequencies greater than 25 kHz. The benefits are: increased lamp efficacy, reduced ballast losses and lighter, smaller ballasts compared to electromagnetic ballasts. Electronic ballasts may also be used with HID (high intensity discharge) lamps (see ELECTROMAGNETIC BALLAST). Energy Policy Act (EPACT) U.S. Energy legislation setting minimum efficacy (lumens/watt) requirements. Federal Canadian legislation sets similar requirements. Federal Communications Commission (FCC) The U. S. federal agency that regulates emissions in the radio frequency portion of the electromagnetic spectrum. Part 18 of the FCC rules specifies electromagnetic interference (EMI) from lighting devices at frequencies greater than 450 kilohertz (kHz). A consumer-rated Class B ballast is designed for use in the home near TV and radio receivers. It produces less electrical noise that could interfere with consumer products. A Class A-rated ballast is designed for use in commercial and industrial applications that are not in the vicinity of TV and radio receivers. Flicker The periodic variation in light level caused by AC operation that can lead to strobe effects. T12 Fluorescent Ballasts Color Rendering Index (CRI) An international system used to rate a lamp’s ability to render object colors. The higher the CRI (based upon a 0-100 scale) the richer colors generally appear. Color Temperature (Correlated Color Temperature – CCT) A number indicating the degree of “yellowness” or “blueness” of a white light source. Measured in kelvins, CCT represents the temperature an incandescent object (like a filament) must reach to mimic the color of the lamp. Yellowish-white (“warm”) sources, like incandescent lamps, have lower color temperatures in the 2700K-3000K range; white and bluish-white (“cool”) sources, such as cool white (4100K) and natural daylight (6000K), have higher color temperatures. The higher the color temperature, the bluer the light will be. Compact Fluorescent Lamp (CFL) The general term applied to fluorescent lamps that are single-ended and that have smaller diameter tubes that are bent to form a compact shape. Some CFLs have integral ballasts and medium or candelabra screw bases for easy replacement of incandescent lamps. Cool White A term loosely used to denote a color temperature of around 4100K. The Cool White (CW) designation is used specifically for T12 and other fluorescent lamps using halophosphors and having a CRI of 62. Core Component of electromagnetic ballast that is surrounded by the coil. Core is comprised of steel laminations or solid ferrite material. Core & Coil Ballast A ballast that uses a “Core & Coil” assembly to operate fluorescent or HID lamps. Refers to copper or aluminum windings on a steel core. Cost of Light Usually refers to the cost of operating and maintaining a lighting system on an ongoing basis. The 88-8-4 rule states that (typically) 88% is the cost of electricity, 8% is labor and only 4% is the cost of lamps. Crest Factor (Lamp Current Crest Factor) Ratio of peak to RMS for any AC waveform. Crest factor can refer to voltage crest factor or current crest factor. Daylight Harvesting Lighting design for building interiors that makes use of daylight as a way of reducing energy consumption. Dimmer, Dimming Control A device used to lower the light output of a source, usually by reducing the wattage it is being operated at. Dimming controls are increasing in popularity as energy-conserving devices. Ecolux® A term for GE lamps that have reduced mercury content and pass the TCLP test. Efficacy A measurement of how effective the light source is in converting electrical energy to lumens of visible light. Expressed in lumens-per-watt (LPW), this measure gives more weight to the yellow region of the spectrum and less weight to the blue and red regions where the eye is not as sensitive. The efficiency of a light source is simply the fraction of electrical energy converted to light, i.e. watts of visible light produced for each watt of electrical power with no concern about the wavelength where the energy is being radiated. For example, T5 Fluorescent Ballasts Bottom Exit (BE) (CFL plug-in ballasts) A configuration with leads or a wire-trap on the bottom or base of the ballast. This type of configuration is usually used when the ballast is mounted onto a junction box plate. Bottom Exit Studs (BES) (CFL plug-in ballasts) A configuration with screw studs mounted on the base plate or bottom of the ballast. The screws are 3/8-inch long with a #8-32 thread size (#8-32 nut). They are mounted on a 2-inch center. The studs are usually used to mount the ballast directly onto a junction box plate. Bulb Size Bulb shape followed by its size (the maximum diameter of the bulb expressed in eighths of an inch). For Compact Fluorescent products, “S”, “D”, “T”, and “Q” are used to represent Single, Double, Triple and Quad Biax® sizes. The code also includes a reference such as T4 to represent the size of the tube. Rectangular headlamps are designated as “Rect” and the number of millimeters horizontally. Canadian Energy Standards Indicates ballast complies with Canadian Energy Standards and meets the requirements of CAN/ CSA C654-M91. Canadian Standards Associations (CSA) Association that generates product performance and safety standards for many Canadian industries. Capacitor Device in ballast that stores electrical energy, and is used for power factor correction and lamp regulation. Cathode Metal filaments that emit electrons in a fluorescent lamp. Negatively charged free electrons emitted by the cathode are attracted to them, creating an electric current between the electrodes. Cathode Resistance Resistance of the cathode in a Fluorescent lamp. It is measured “cold” before the lamp is turned on (Rc) or “hot” after the lamp is turned on (Rh). The ratio of the hot resistance to the cold resistance is also measured (Rh/Rc). Ceramic Metal Halide A type of metal halide lamp that uses a ceramic material for the arc tube instead of glass quartz, resulting in better color rendering (>80 CRI) and improved lumen maintenance. GE ConstantColor® CMH® lamps deliver reliability and excellent color. ChromaFit A GE brand name for metal halide lamps designed to operate on HPS ballasts, allowing a user to switch from the yellowish color of HPS to the white color of metal halide without changing ballasts. These products are available in both quartz metal halide and ceramic metal halide (CMH) versions. Class P Thermal Protector A switching device sensitive to current and heat that automatically disconnects ballast if the temperature exceeds UL temperature limitations. Coefficient of Utilization (CU) In general lighting calculations, the fraction of initial lamp lumens that reach the work plane. CU is a function of luminaire efficiency, room surface reflectances and room shape. Coil Windings of copper or aluminum wire surrounding the steel core in ballast. Also refers to the entire assembly comprising the inductor or transformer. T8 Fluorescent Ballasts Amperes (“Amps.”) A measure of electrical current. The current is related to voltage and power as follows: Watts (power) = Volts x Amps (current). ANSI (American National Standards Institute) A consensus-based organization which coordinates voluntary standards for the physical, electrical and performance characteristics of lamps, ballasts, luminaires and other lighting and electrical equipment. ANSI Ballast Type Ballast type used to operate lamp in accordance with ANSI standard. ANSI Codes These are 3-letter codes assigned by the American National Standards Institute. They provide a system of assuring mechanical and electrical interchangeability among similarly coded lamps from various manufacturers. General Electric uses the assigned ANSI Codes as Lamp Ordering Codes for most Projection Lamps. Auto Reset Shutdown Circuit Circuit senses lamp end life and will automatically shut off power to the lamp(s). When a new lamp is inserted in the socket, the ballast resets, and turns on the lamp automatically. Some shutdown circuits require the power to be cycled before a new lamp will re-light. Ballast An auxiliary piece of equipment required to start and to properly control the flow of current to gas discharge light sources such as fluorescent and high intensity discharge (HID) lamps. Typically, magnetic ballasts (also called electromagnetic ballasts) contain copper windings on an iron core while electronic ballasts are smaller and more efficient and contain electronic components. Ballast Efficacy Factor (BEF) Defined as ballast factor x100 divided by input watts. The value is used to evaluate various lighting systems based on light output and power input. The BEF can only be used to compare systems operating the same type and quantity of lamps. Ballast Factor (BF) This is the percentage of a lamp’s rated lumen output that can be expected when operated on a specific, commercially available ballast. Note that the “rated output” is sometimes measured on a reference ballast unlike ones that actually operate the lamp in the field. For example, a ballast with a ballast factor of 0.93 will result in the lamp’s emitting 93% of its rated lumen output. A ballast with a lower BF results in less light output and also generally consumes less power. Ballast Hum Sound generated by the vibration of laminations in the iron core or inductor in the ballast. Ballast Losses Power or energy dissipated in the ballast as heat and not converted to lamp energy. Base Temperature (Maximum) The maximum operating temperature permitted for the base in Celsius. Fixture manufacturers need to ensure that these conditions are satisfied. Bi-Pin Any base with two metal pins for electrical contact. This is the typical base for a fluorescent tube of 1 to 4 feet in length. It consists of 2 prong contacts that connect into the fixture. Medium bi-pins are used with type T-8 and T-12 tubular fluorescent lamps, and miniature bi-pins are used for tubular T-5 fluorescent lamps. 186 Quick Reference Guides gelighting.com Glossary (cont.) HID Electromagnetic Ballasts 189 HID Electronic Ballasts HID ballast which can operate PulseArc® and CMH® lamps anywhere from 250 watts to 400 watts and provides greatly improved lumen maintenance. UltraStart® Ballast A family of high-efficiency GE programmed start electronic linear fluorescent ballasts designed to optimize GE’s T8 Ultra lamps in frequently switched applications. Instant start ballast provides 10,000 starts. UltraStart® provides 100,000 to 200,000 starts. Use programmed start ballast to ensure long lamp life when turning lamps on and off more than twice a day. Ultraviolet (UV) Radiation Radiant energy in the range of about 100-380 nanometers (nm). For practical applications, the UV band is broken down. The International Commission on Illumination (CIE) defines the UV band as UV-A (315-400 nm); UV-B (280-315 nm) and UV-C (100-280 mm). Ultra Watt-Miser® GE’s family of energy-saving T8 fluorescent lamps. Veiling Reflection Reflected glare from a light source bouncing off a shiny surface. Visual Comfort Probability (VCP) VCP is the percent of people who find the lighting scheme acceptable in terms of glare. Volt A measure of “electrical pressure” between two points. The higher the voltage, the more current will be pushed through a resistor connected across the points. The volt specification is the electrical “pressure” required to drive it at its designated point. The “voltage” of a ballast (e.g. 277 V) refers to the line voltage it must be connected to. Voltage A measurement of the electromotive force in an electrical circuit or device expressed in volts. Voltage can be thought of as being analogous to the pressure in a water line. Wall Temperature (Maximum Bulb) The maximum operating bulb wall temperature. Warm-Up Time to 90% The time it takes for a HID lamp to reach 90% of light output after being turned on. Warm White Refers to a color temperature around 3000K, providing a yellowish-white light. Watt A unit of electrical power. Lamps are rated in watts to indicate the rate at which they consume energy (see KILOWATT HOUR). Watt-Miser® A Watt-Miser® lamp is a term used by GE to indicate a reduced-wattage lamp with performance characteristics (life, light output, etc.) such that it can usually directly replace a higherwattage product. Wattage Indicator Reduced Indicates that this is a reduced wattage option for lamps normally used in this application. Be sure to check wattage, lumens and life to determine which lamp is best suited to your needs. Wavelength The distance between two neighboring crests of a traveling wave. The wavelength of light is between 400 and 700 nanometers. Compact Fluorescent Ballasts TCLP Test The Toxicity Characteristic Leaching Procedure (TCLP) test, specified in the U.S. Resource Conservation and Recovery Act (RCRA) of 1990, is used to characterize fluorescent lamp waste as hazardous or nonhazardous waste. The TCLP test measures the ability of the mercury and/or lead in a lamp to leach from a landfill into groundwater (see ECOLUX). THD (See TOTAL HARMONIC DISTORTION.) Terminal-to-Terminal Starting Lamp Voltage (VRMS) (Minimum or Maximum) The minimum or maximum voltage allowed into lamp from ballast under varying conditions as specified. Total Harmonic Distortion (THD) A measure of the distortion of the input current on alternating-current (AC) power systems caused by higher-order harmonics of the fundamental frequency (60Hz in North America). THD is expressed in percent and may refer to individual electrical loads (such as ballast) or a total electrical circuit or system in a building. ANSI C82.77 recommends THD not exceed 32% for individual commercial electronic ballasts, although some electrical utilities may require lower THDs on some systems. Excessive THDs on electrical systems can cause efficiency losses as well as overheating and deterioration of system components. Transients High voltage surges through an electrical system caused by lightning strikes to nearby transformers, overhead lines or the ground. May also be caused by switching of motors or compressors, as well as by short circuits or utility system switching. Can lead to premature ballast failure. Troffer A long, recessed lighting unit, usually installed in an opening in the ceiling. Two-Pin Compact Fluorescent Lamps Type of lamps that have the glow bottle starter built into the base of the lamp. Traditionally two-pin lamps work with electromagnetic ballasts. Underwriters Laboratories (UL) A private organization which tests and lists electrical (and other) equipment for electrical and fire safety according to recognized UL and other standards. A UL listing is not an indication of overall performance. Lamps are not UL listed except for compact fluorescent lamp assemblies—those with screw bases and built-in ballasts. Uniform Product Code (UPC) The 12-digit code on the saleable unit that is used for scanning at the register. Ultra A common way of referring to high-efficiency GE T8 family of lamps and ballast that performs better than standard T8 lamps. Also refers to the system. UltraMax® Ballast A family of high-efficiency GE instant-start electronic linear fluorescent ballasts designed to optimize GE’s T8 Ultra lamps for enhanced system energy savings. UltraMax® ballasts have a low lamp current crest factor and virtually “read” and adapt to incoming voltage from 108V to 305V. Other features include UL Type CC Anti-Arc Rating and anti-striation control to eliminate lamp striations and spiraling. GE also has an UltraMax® Sign Ballasts Scotopic/Photopic (S/P) Ratio This measurement accounts for the fact that of the two light sensors in the retina, rods are more sensitive to blue light (scotopic vision) and cones to yellow light (photopic vision). The scotopic/photopic (S/P) ratio is an attempt to capture the relative strengths of these two responses. S/P is calculated as the ratio of scotopic lumens to photopic lumens for the light source on an ANSI reference ballast. Cooler sources (higher color temperature lamps) tend to have higher values of the S/P ratio compared to warm sources. Self-Ballasted Lamps A discharge lamp with an integral ballasting device allowing the lamp to be directly connected to a socket providing line voltage (see CFL). Series Lamp Operation Refers to ballasts that employ a single current path passing through all lamps operated by the ballast. If one lamp should fail, companion lamps operated by the same ballasts will also extinguish or dim. Spacing-to-Mounting-Height Ratio Ratio of fixture spacing (distance apart) to mounting height above the work plane; sometimes called spacing criterion. It is OK to have fixtures spaced closer than the spacing criterion suggested by the manufacturer but not farther, or you will get dark spots in between fixtures. Specification Series (SP) Colors Energy-efficient, all-purpose, tri-phosphor fluorescent lamp colors that provide good color rendering. The CRI for SP colors is 70 or above and varies by specific lamp type. Specification Series Deluxe (SPX) Colors Energy-efficient, all-purpose, tri-phosphor fluorescent lamp colors that provide better color rendering than Specification Series (SP) colors. The CRI for SPX colors is 80 or above and varies by specific lamp type. All GE CFL products use SPX phosphors. Specification Series Deluxe eXtreme (SPXX) Colors A color designation for GE ceramic metal halide lamps with superior color rendering ~ 90. Specular Reflection Reflection from a smooth, shiny surface, as opposed to diffuse reflection. Spiral® Lamp GE trademark for its helical family of highefficiency, long-life compact fluorescent lamps. Starcoat® GE’s special barrier coating applied on the inside of all GE T8 fluorescent lamps, as well as some other lamp types, to enhance lamp life and deliver superior lumen maintenance. Starter An electronic module or device used to assist in starting a discharge lamp, typically by providing a high-voltage surge (see IGNITOR). Starting Temperature (Minimum) The minimum ambient temperature at which the lamp will start reliably. T-12, T-8, T-5 A designation for the diameter of a tubular bulb in eighths of an inch; T-12 is 12 eighths of an inch, or 1-1/2 inches; T-8 is 1 inch, and so on. Task Lighting Supplemental lighting provided to assist in performing a localized task, e.g., a table lamp for reading or an inspection lamp for fabric inspection. T12 Fluorescent Ballasts Power Factor Corrected Ballasts that incorporate a means of Power Factor Correction yielding power factor of 90% or greater. Preheat Circuit A type of fluorescent lamp-ballast circuit used with the first commercial fluorescent lamp products. A push-button or automatic switch is used to preheat the lamp cathodes to a glow state before starting. Product Code Five-digit code to identify the product. Programmed Rapid Start Lamp starting method which preheats the lamp filaments while not allowing the lamp to ignite and then applies the open circuit voltage (OCV) to start the lamp. This type of starting circuit keeps lampend blackening to a minimum and improves lamplife performance, especially in applications where the lamps are frequently switched on and off. PulseArc® GE description for a type of metal halide lamp that provides improved lumen maintenance for longer useful life and extended relamp cycles. These products are designed to operate on ballasts that have ignitors to help with lamp starting. Pulse Start An HID ballast with a high voltage ignitor to start the lamp. Quartz A name for fused silica or melted sand from which many high-temperature containers are fashioned in the lighting industry. Quartz looks like glass but can withstand the high temperatures needed to contain high intensity arc discharges. Radiation A general term for the release of energy in a “wave” or “ray” form. All light is radiant energy or radiation, as is heat, UV, microwaves, radio waves, etc. Rapid Start Circuit A fluorescent lamp-ballast circuit that utilizes continuous cathode heating, while the system is energized, to start and maintain lamp light output at efficient levels. Rapid start ballasts may be either electromagnetic, electronic or of hybrid designs. Full-range fluorescent lamp dimming is only possible with rapid start systems (see INSTANT START). Rapid Start Lamp starting method in which lamp filaments are heated while open circuit voltage (OCV) is applied to facilitate lamp ignition. A Rapid Start fluorescent lamp has two pins at each end connected to the filament. The filaments are heated by the ballast to aid in starting. Some rapid start lamps may be instant started without filament heat, for example the F32T8 lamp. Rated Lamp Life For most lamp types, rated lamp life is the length of time of a statistically large sample between first use and the point when 50% of the lamps have died. It is possible to define “useful life” of a lamp based on practical considerations involving lumen depreciation and color shift. Room Cavity Ratio (RCR) A shape factor (for a room, etc.) used in lighting calculations. RCR = 5H (L+W) / L x W, or, alternately, RCR = (2.5) Total Wall Area / Floor Area. Where H = height, L = length and W = width of the room. A cubical room will have an RCR of 10; the flatter the room the lower the RCR. T5 Fluorescent Ballasts 188 Multi-Vapor® A GE brand for metal halide lamps. National Electric Code (NEC) A nationally accepted electrical installation code to reduce the risk of fire, developed by the National Fire Protection Association. National Energy Standards for Fluorescent Ballasts A federal law enacted in 1988 that sets energy standards for ballasts consistent throughout the United States. National Stock Number The standardized part number used by the U.S. Government for procurement. NOM Laboratory that sets safety standards for building materials and electrical products for Mexico. Non-PCB Capacitor Capacitor used in ballasts to help provide power factor correction. Contains no polychlorinated biphenyls and meets EPA requirements. Normal Power Factor Ballasts with power factor less than .90 and do not incorporate any means of Power Factor Correction. Open Circuit Voltage (OCV) Open Circuit Voltage measured across the socket the lamp screws into, with the ballast powered on. It is dangerous to stick a voltmeter into such a socket without precise knowledge of the ballast because exceedingly high voltages could be present. Operating Voltage For electrical discharge lamps, this is the voltage measured across the discharge when the lamp is operating. It is governed by the contents of the chamber and is somewhat independent of the ballast and other external factors. Parallel Lamp Operation Refers to ballasts that employ multiple output current paths from a single ballast to allow lamps to operate independently of one another, allowing other lamps operated by the ballast to remain lit should companion lamp(s) fail. PCB (Polychlorinated Biphenyls) Chemical pollutant formerly used in ballast capacitors that were part of ballasts. It is now illegal to use PCBs and most such ballasts have been replaced over time. Phosphor An inorganic chemical compound processed into a powder and deposited on the inner glass surface of fluorescent tubes and some mercury and metalhalide lamp bulbs. Phosphors are designed to absorb short wavelength ultraviolet radiation and to transform and emit it as visible light. Potting Material used to completely surround and cover components of some magnetic and electronic ballasts. Potting compound fulfills functions of protecting components, dampening sound, and dissipating heat. Power Factor Measurement of the relationship between the AC source voltage and current. High-power factor ballasts require less AC operating current at the same wattage than an equivalent low-power factor ballast. Formula: power factor equals input watts divided by the product of line volts times line amps (volt amps or VA). T8 Fluorescent Ballasts Lumens/Watts A ratio expressing the luminous efficacy of a light source. Typical lamp efficacies: • Thomas Edison’s first lamp - 1.4 lpW • Incandescent lamps - 10-40 • Halogen incandescent lamps - 20-45 • Fluorescent lamps - 35-105 • Mercury lamps - 50-60 • Metal halide lamps - 60-120 • High-pressure sodium lamps - 60-140 Note: The values above for discharge lamps do not include the effect of the ballasts, which must be used with those lamps. Taking ballast losses into account reduces “system” or lamp-ballast efficacies typically by 10-20% depending upon the type of ballast used. Lumen Maintenance A measure of how well a lamp maintains its light output over time. Luminaire Efficiency The ratio of total lumens emitted by a luminaire to those emitted by the lamp or lamps used in that luminaire. Luminaire A complete lighting unit consisting of a lamp, ballast as required, together with the parts designed to distribute the light, position and protect the lamps and connect them to the power supply. A luminaire is often referred to as a fixture. Lux (lx) A unit of illuminance or light falling onto a surface. One lux is equal to one lumen per square meter. Ten lux approximately equal one footcandle (see FOOTCANDLE). Mean Lumens The average light output of a lamp over its rated life. Based on the shape of the lumen depreciation curve, for fluorescent and metal halide lamps, mean lumens are measured at 40% of rated lamp life. For mercury, high-pressure sodium and incandescent lamps, mean lumen ratings refer to lumens at 50% of rated lamp life (see LUMEN MAINTENANCE). Medium Base Usually refers to the screw base typically used in household incandescent lamps. There is also the medium bi-pin base commonly used in T12 and T8 fluorescent lamps. Metal Cases Case design used in both magnetic and electronic ballasts. These ballasts are grounded once they are mounted to the fixture. They meet all safety codes, some of which do not allow plastic in open plenum areas. Metal Halide Lamp A high intensity discharge light source in which the light is produced by the radiation from mercury, plus halides of metals such as sodium, scandium, indium and dysprosium. Some lamp types may also utilize phosphor coatings. GE trade names include: Multi-Vapor®, ConstantColor® CMH®, PulseArc®, Staybright®, Watt-Miser®, ChromaFit and Arcstream®. Mogul Base A screw base used on larger lamps, e.g. many HID lamps. Mounting Height Distance from the bottom of the fixture to either the floor or work plane, depending on usage. Quick Reference Guides gelighting.com Ballast cross reference matrix Prod Code Description Advance P/N Universal P/N OSI P/N Howard P/N 96721 29672 29625 29627 96716 71832 29678 T8 INSTANT START BALLASTS ® UltraMax Instant Start Multi-Voltage High Efficiency GE132MAX-L/ULTRA GE132MAX-N/ULTRA GE232MAX-H/ULTRA GE232MAX-L/ULTRA GE232MAX-N/ULTRA GE232MAX-N+ GE332MAX-H/ULTRA GE332MAX-L/ULTRA GE332MAX-N/ULTRA GE332MAX-N+ GE432MAX-H/ULTRA GE432MAX-L/ULTRA GE432MAX-N/ULTRA GE432MAX-N+ GE159MAX-N/ULTRA GE259MAX-N/ULTRA IOP-1P32LW-SC IOP-1P32-SC IOP-2P32HL-SC IOP-2P32LW-SC IOP-2P32-SC B132IUNVEL-A B132IUNVHE-A B232IUNVHEH-A B232IUNVEL-A B232IUNVHE-A IOP-3P32HL-90C-SC IOP-3P32LW-SC ICN-3P32-SC B332IUNVHEH-A B332IUNVEL-A B332IUNVHE-A IOP-4P32HL90CG IOP-4P32LW-SC ICN-4P32-SC B432IUNVEL-A B432IUNVHE-A QHE 1X32T8/UNV ISN-SC-1 QHE 2X32T8/UNV ISN-SC-1 QHE 4X32T8/UNV ISH-SC-1 72273 GE-232-MV-L 72275 GE-232-MV-N 30199 GE-332-MV-H 30255 GE-332-MV-L 30192 30219 GE-332-MV-N GE-432-MV-H 30262 GE-432-MV-L 30193 30195 GE-432-MV-N GE-159-MV-N 30194 GE-259-MV-N GE-286-HO-MV-N UltraStart® T5 Programmed Rapid Start IOP-2P59-SC QTP 1X32T8/UNV ISL-SC/QHE ICN-1P32-SC B132IUNVHP-B 1X32T8/UNV ISN-SC QTP 2X32T8/UNV ISH-SC/QHE REL-2P32-HL-SC/VEL-2P32-HL-SC B232I120RHH-A/B232I277RHH-A 2X32T8/UNV ISH-SC QTP 2X32T8/UNV ISL-SC/QHE REL-2P32-LW-SC/VEL-2P32-LW-SC B232I120L-A/B232I277L-A 2X32T8/UNV ISL-SC QTP 2X32T8/UNV ISN-SC/QHE ICN-2P32-SC B232IUNVHP-B 2X32T8/UNV ISN-SC QTP 3X32T8/UNV ISH-SC/QHE REL-3P32-HL-SC/VEL-3P32-HL-SC B332I120RHH-A/B332I277RHH-A 3X32T8/UNV ISH-SC QTP 3X32T8/UNV ISL-SC/QHE REL-3P32-LW-SC/VEL-3P32-LW-SC B332I120L-A/B332I277L-A 3X32T8/UNV ISL-SC QTP 3X32T8/UNV ISN-SC/QHE ICN-3P32-SC B332IUNVHP-B 3X32T8/UNV ISN-SC REL-4P32-HL-SC/VEL-4P32-HL-SC B432I120RHH-A/B432I277RHH-A QHE 4X32T8/UNV ISH-SC QTP 4X32T8/UNV ISL-SC/QHE REL-4P32-LW-SC/VEL-4P32-LW-SC B432I120L-A/B432I277L-A 4X32T8/UNV ISL-SC QTP 4X32T8/UNV ISN-SC/QHE ICN-4P32-SC B432IUNVHP-B 4X32T8/UNV ISN-SC RCN-2P59/VCN-2P59 RCN-2S86 GE-132-120-N GE-132-277-N GE-232-120-N GE-232-277-N GE-332-120-N GE-332-277-N GE-432-120-N GE-432-277-N GE-259-120-N GE-259-277-N RCN-1P32-SC VCN-1P32-SC RCN-2P32-SC VCN-2P32-SC RCN-3P32-SC VCN-3P32-SC RCN-4P32-SC VCN-4P32-SC RCN-2P59 VCN-2P59 Residential Grade ProLine® T8 120V GE232-120-RES GE432-120-RES REB232-SC REB4P32-SC Electromagnetic T8 Ballasts 87125 87130 GEM232T8RS120 GEM232T8RS277 B259IUNVHP-B QTP 2X59T8/UNV ISN-SC/QHE 2X59T8/UNV-ISN-SC B259I120RHH/B259I277RHH QHE 2X86T8HO/UNV-PSN-HTSCL/QHE2X59T8/UNV-ISH R-2P32-TP V-2P32-TP B132I120RH-A B132I277RH-A B232I120RH-A B232I277RH-A B332I120RH-A B332I277RH-A B432I120RH-A B4132I277RH-A EPL2/32IS-120-277 EP2/32IS-120-277 EPL3/32IS-120-277 EP3/32IS-120-277 EPL4/32IS-120-277 EP4/32IS-120-277 QT1X32T8/120/ISN-SC QT1X32T8/277/ISN-SC QT2X32T8/120/ISN-SC QT2X32T8/277/ISN-SC QT3X32T8/120/ISN-SC QT3X32T8/277/ISN-SC QT4X32T8/120/ISN-SC QT4X32T8/277/ISN-SC QT2X59/120IS QT2X59/277IS B232I120RES-A B432I120RES-A M232SR120C M232SR277C UltraStart T8 Program Rapid Start B132R120V5 B232SR120V5 B232SR277S50 B232SR277V5 B332SR120V5 B332SR277V5 99649 29726 72280 GE454MVPS90-E GE454MVPSN1 GE180MVPS-D B232PUNVHP-A QTP 2X32T8/UNVPSN-TC QTP 2X32T8/UNV PSX-TC QHE2x32T8/UNV-PSH-HT B332PUNVHP-A QTP 3X32T8/UNVPSN-SC See page 195 for warranty information. ICN-2S28 ICN-2S24 ICN-2S39 ICN-2S54-90C ICN-2S54 ICN4S5490C2LSG ICN4S5490C2LS B228PUNV115-D B228PUNV95-D B228PUNV-C B224PUNV-D B239PUNV-D B254PUNV-D B254PUNV-D QTP2X28T5/UNVPSN NL QTP2X39-24T5HO/UNVPSN NL QTP2X39-24T5HO/UNVPSN NL QTP 2X54T5HO/UNV PSN HT B454PUNV-E QTP2X54T5HO/UNVPSN NL QTP 4X54T5HO/UNV PSN HTW NL QTP 4X54T5HO/UNV PSN HT QTP1X80T5HO/UNVPSN NL B240R120HP/B240R277HP B234SR120M-A B134SR120M-A B340R120HP/B340R277HP B260IUNVHP B295SR120HP B295SR277HP B295SRUNVHP QTP2X40T12/120RSN-SC QTP1X40T12/120/277RSN-SC QTP3X40T12/120/277RSN QT2x96/120IS/QT2x96/277IS QT2x96/120HO QT2x96/277HO EP2/54HO/PRS/MV/90C EP2/54HO/PRS/120-277 T12 Fluorescent Ballasts T12 ELECTRONIC BALLASTS ProLine® T12 Multivolt 120V - 277V 24107 97498 72110 24109 24108 80162 80163 72109 GE-240-RS-MV-N GE240RS120 GE140RS120-DIY GE-340-RS-MV-N GE-260-IS-MV-N B295SR120HP B295SR277HP GE296HO-MV-N R-140-TP REL-2S40-SC/RELB-2S40-SC REL-1S40-SC R-3S34-TP R2E75STP REL-2P60-S-A/REL-2S110 VEL-2P75-S/VEL-2S110 T12 MAGNETIC BALLASTS 89711 89712 89720 86227 89717 80819 89714 89709 80644 89710 86139 86124 86341 86372 86381 86360 86379 86164 86171 GEM120PH120DIY GEM120TC120DIY GEM1FC16T9RS120 GEM1FC8T9RS120IP GEM1FC12T9RS120 GEM220TS120DIY GEM140HRS120DIY GEM140RS120DIY GEM230RS120 GEM240HRS120DIY GEM240RS120IP GEM240RS277IP GEM240RS220 GEM196IS120IP GEM196IS277 GEM296IS120IP GEM296IS277IP GEM296HORS120IP GEM296HORS277 GESB-0412-12-IP GESB-0620-24-IP GESB-1224-24-IP GESB-1240-46-IP GESB-2040-46-IP GESB-2448-46-IP See page 195 for warranty information. LC-14-20-C-TP RLQ-120-TP RMS-3240-TP-W RLQS-122-TP-W RS-22-32-TP-W RS-2SP20-TP R-140-TP RL-140-TP RM-2SP30-TP RK-2S34-TP R-2P840-TP V2S40TP MTM-2S40-TP RSM175STP VSM175STP R2E75STP V2E75STP R-2S110-TP V-2S110-TP 200H2 546BTCP 726VLHWSTCP 547RSWSTCP 449LRWSTCP 447LRVLHTCP 412LSLHTCP 413CTCP 573LTCP 420LTCP 446LSLHTCP 443LSLHTCP 754LTCP 822BRTCP 828BRTCP 806SLHTCP 827SLHTCP 480SLHTCP 487SLHTCP ASB-0412-12-BL-TP ASB-0620-24-BL-TP ASB-1224-24-BL-TP ASB-1240-46-BL-TP ASB-2040-24-BL-TP ASB-2448-46-BL-TP USB-0412-12-IP USB-0816-14-IP USB-1024-14-IP USB-2036-46-IP USB-1632-24-IP USB-2048-46-IP 191 HID Electromagnetic Ballasts 190 RCN-2S32-SC VCN-2S32-SC IOP-2S32-SC IOP-2S32-LW-SC N/A N/A RCN-3S32-SC VCN-3S32-SC IOP-3S32-SC IOP-3S32-SC GE228MVPSH-A GE228MVPS-A B228PUNV-C0G1C B224PUNV-COG1C B239PUNV-DOG1C GE254MVPS90-F B254PUNV-DGE1C GE254MVPS-D 72103 72104 72105 72106 72107 72108 ® GE-232-120-PS-N GE-232-277-PS-N GE232-MVPS-N GE232-MVPS-L GE-232-MVPS-H GE-232-MVPS-XL GE-332-120-PS-N GE-332-277-PS-N GE-332-MVPS-H GE332-MVPS-N 99653 99655 47536 47534 47540 99651 47542 72279 Sign Ballasts T8 PROGRAM START BALLASTS 29621 29622 96714 96720 29675 29671 29623 29624 29676 96715 QTP 4X32T8/UNVPSN-SC QTP 4X32T8/UNV PSX-SC QHE4x32T8/UNV-PSH-HT HID Electronic Ballasts 97782 97783 B432PUNVHP-A Compact Fluorescent Ballasts ProLine® T8 Instant Start High-Performance 23680 23681 23671 23672 23673 23674 23675 23676 23677 23678 QTP 3X32T8/UNV PSX-SC QHE3x32T8/UNV-PSH-HT T5 ELECTRONIC PROGRAMMED START BALLASTS ProLine® T8 Multivolt High Output 120V - 277V 30176 RZT-132 RZT-2S32 VZT-2S32 VZT-2S32 RZT-3S32 VZT-3S32 Howard P/N Sign Ballasts GE-232-MV-H B132R120V5 B232SR120V5 B232SR277S50 B232SR277V5 B332SR120V5 B332SR277V5 IOP-3S32-LW-SC N/A RCN-4S32-SC VCN-4S32-SC IOP-4S32-SC IOP-4S32-LW-SC OSI P/N T12 Fluorescent Ballasts 30198 Universal P/N T5 Fluorescent Ballasts ProLine T8 Multivolt 120V - 277V GE-132-MV-N GE332-MVPS-L GE-332-MVPS-XL GE-432-120-PS-N GE-432-277-PS-N GE432-MVPS-N GE432-MVPS-L GE-432-MVPS-H T8 Dimming 80353 80355 80362 80356 80357 80358 QHE 3X32T8/UNV ISH-SC-1 ® 72269 Advance P/N T5 Fluorescent Ballasts 72258 72259 49775 72262 72266 71421 71714 71717 71719 71422 71723 71725 71727 71423 49766 49767 Description T8 Fluorescent Ballasts T8 Fluorescent Ballasts T8 Fluorescent Ballasts Prod Code Quick Reference Guides gelighting.com Ballast cross reference matrix (cont.) Prod Code Description Advance P/N Universal P/N OSI P/N Robertson P/N CFL ELECTRONIC GEC213-MVPS-BES GEC213-MVPS-SE GEC213-MVPS-3W GEC218-MVPS-BES GEC218-MVPS-SE GEC218-MVPS-3W GEC226-MVPS-BES GEC226-MVPS-SE GEC226-MVPS-3W C242UNVBES-IP C242UNVSE-IP C240PUNVHP-B-IP C240SI120RH-IP C240SI277RH-IP C340SI120RH-IP C340SI277RH-IP GEM1CF579PH277 GEM1CF13PH120 GEM2CF13PH277 GEM2CF24PH277 GEM2FT36RS120 GEM2FT40RS120 87490 87501 87516 87531 87546 87561 87576 29377 89646 GEMH20-MLF-120 GEMH39-MSF-120 GEMH50-MSF-120 GEMH70-MSF-120 GEMH70-SLJ-MV GEMH100-SLJ-MV GEMH150-SLJ-MV GE-MH-250-400-MA GEMH250-400M-V50 ICF-2S26-BS ICF-2S26-LD C213UNVBS C213UNVBES C213UNVME00K C218UNVBS C218UNVBES C218UNVME000K C2642UNVBES-IP C2642UNVSE-IP IZT-2S42-M2-BS IZT-2S42-M2-LS REL-2TTS40 RCN-2TTP40-SC VCN-2TTP40-SC RCN-3TTP40-SC VCN-3TTP40-SC VL-1B9-TP-W LC-13-TP VH-2B13-TP-BLS VH-2Q26-TP-BLS R-2BS39-TP R-2BS40-TP C2642UNVBE C2642UNVSE C240PUNVHP-B-IP C240SI120RH-IP C240SI277RH-IP C340SI120RH-IP C340SI277RH-IP 4205F2P 4111H2P 4214PBES 4226PBES 4150P 4152P Advance P/N Universal P/N ICF-2S18-BE ICF-2S18-LD PSG242TRMVBS PSG242TRMV AROMAT/VS P/N QTP1X20MH/UNV F QTP1X39MH/UNV F M2012-27CK-5EUF M3912-27CK-5EUF IMH-70-G IMG-70-G IMG-100-A-BLS IMG-150-H-BLS IZTEMH4003PS ECN70-120 ECN70-UNV ECN100-UNV ECN150-UNV QTP1X70MH/UNV F QTP1X70MH/UNV J QTP1X100MH/UNV J M7012-27CK-5EUF M7012-27CK-5EUJ M10012-27CK-5EUJ M15012-27CK-5EUN-J QHE1XxxxMH 208-277V 71A5593-001D 71A5543-500DT 71A5792-001D 71A5742-500DT 71A5892-001D 71A5842-500DT 71A5837-001D 71A5993-001D 71A6042-500DT 71A6092-001D 71A64F2-500DT 71A64E2-500D 71A6593-500 71A6553-500 P175MLTAC3M500K P17548TAC3M500K P250MLTAC4M500K P25048TAC4M500K P320MLTAC4M500K P32048TAC4M500K P320TRIAC4M502K P350MLTAC4M500K P40048TAC4M500K P400MLTAC4M500K P75048TAC5M500K P750MLTAC5M500K P1000MLTAC5M500K P1000ML5AC5M500K GEM175ML5AC3-55 GEM250ML5AC3-55 GEM400ML5AC4-55 GEM1000ML5AC4-55 GES100MLTLC3D-55 GES250ML5AC4-55 GES400ML5AC4-55 F-Can & Post Mount Metal Halide 86576 86578 86574 86563 86564 42670 80728 11210277CTC000C 11210506CTC000C 11210239CTC000I 1110245SCTC000I 1110246CTC000C 1110-247SC-TC 1111-247SCTC000I 72C5280-NP 72C5282-NP 72C5381-NP 72C5581-NP 72C5782-NP 72C6082-NP 72C6082-NP F-Can & Post Mount HPS 1233142U000I 12210237CTC000I 1233154U000I 71A7907-001DB 72C7984-NP 71A8107-001DB 11210277CTC000C 11210506CTC000C 11210239CTC000I 1110245SCTC000I 1110246CTC000C 1110-247SC-TC 1111-247SCTC000I 1233142U000I 12210237CTC000I 1233154U000I See page 195 for warranty information. See page 195 for warranty information. 193 HID Electromagnetic Ballasts 71A5390-001D 71A5340-500DT 71A5492-500D 71A5442-500DT 71A3042-001D 71A5570-001D 71A5750-001D 71A3542-001D 71A5750 71A6051-001D 71A6071-001D 71A6042-500DT 71A6542-001 71A6552-001 71A6572-001 71A6742-001 71A6772-001 71701 71702 71703 71704 71705 71706 71707 86605 86596 86606 EPXXXMRVASE M50MLTLC3M500K M70MLTLC3M500K M7048TLC3M500K M100MLTLC3M500K M10048TLC3M500K M150MLTLC3M500K M15048TLC3M500K M175ML5AC3M500K M175MLTAC3M500K M250ML5AC3M500K M250MLTAC3M500K M250ML5AC4M500K M400ML5AC4M500K M400MLTAC4M500K M40048TAC4M500K M100048TAC5M500K M1000ML5AC5M500K M1000MLTAC5M500K M150048TAC5M500K M1500MLTAC5M500K S50MLTLC3M500K S70MLTLC3M500K S7048TLC3M500K S100MLTLC3M500K S10048TLC3M500K S150MLTLC3M500K S15048TLC3M500K S250ML5AC4M500K S250MLTAC4M500K S400ML5AC4M500K S400MLTAC4M500K S40048TAC4M500K S100048TAC5M500K S1000ML5AC5M500K S1000MLTAC5M500K HID Lamp-Ballast Kits ECN20-120 ECN39-120 71A5181-500D 71A5280-500D 71A7801-001D 71A7971-001D 71A7941-001D 71A8001-001D 71A8041-001D 71A8172-001D 71A8142-001D 71A8251-001D 71A8271-001D 71A8453-001D 71A8473-001D 71A8443-001D 71A8743-001 71A8753-001 71A8773-001 HID Electronic Ballasts 192 GEP175MLTAC3-5 GEP17548TAC3-5 GEP250MLTAC4-5 GEP25048TAC4-5 GEP320MLTAC4-5 GEP32048TAC4-5 GEP320TRIAC4-5 GEP350MLTAC4-5 GEP40048TAC4-5 GEP400MLTAC4-5 GEP75048TAC5-5 GEP750MLTAC5-5 GEP1000MLTAC5-5 GEP1000ML5AC5-5 PSG242TRMVBS PSG242TRMV GES50MLTLC3D-5 GES70MLTLC3D-5 GES7048TLC3D-5 GES100MLTLC3D-5 GES10048TLC3D-5 GES150MLTLC3D-5 GES15048TLC3D-5 GES250ML5AC4-5 GES250MLTAC4-5 GES400ML5AC4-5 GES400MLTAC4-5 GES40048TAC4-5 GES100048TAC5-5 GES1000ML5AC5-5 GES1000MLTAC5-5 AROMAT/VS P/N Compact Fluorescent Ballasts Pulse Start 86885 86876 86935 86926 86959 86952 86968 86984 86999 87008 46936 46934 72281 72282 PSM218CQMVBS PSM218CQMV 87152 86587 86456 87074 87068 87094 87087 87214 87121 87215 87164 87198 87048 87218 87056 OSI P/N Sign Ballasts GEM50MLTLC3D-5 GEM70MLTLC3D-5 GEM7048TLC3D-5 GEM100MLTLC3D-5 GEM10048TLC3D-5 GEM150MLTLC3D-5 GEM15048TLC3D-5 GEM175ML5AC3-5 GEM175MLTAC3-5 GEM250ML5AC3-5 GEM250MLTAC3-5 GEM250ML5AC4-5 GEM400ML5AA4-5 GEM400MLTAA4-5 GEM40048TAC4-5 GEM100048TAC5-5 GEM1000ML5AA5-5 GEM1000MLTAA5-5 GEM150048TAC5-5 GEM1500MLTAC5-5 OSI P/N PSM213CQMVBS PSM213CQMV RMH-20-E RMH-39-K HID Electromagnetic Ballasts Metal Halide 86824 86847 86839 86675 86667 86718 86711 87210 86741 87211 86765 87212 72300 72149 86803 86650 87213 86655 86693 86698 QTP1/2X13CF/UNVBS QTP1/2X13CF/UNVTS QTP 1/2x13CF/UNV QTP1/2X18CF/UNVBS QTP1/2X18CF/UNVTS QTP 1/2x18CF/UNV QTP2X26CF/UNVBS QTP2X26CF/UNVTS QTP 1/2x26CF/UNV QTP2X26/32/42CF/UNVPM QTP2X26/32/42CF/UNVTM QTP2X40TT5/120/277PSN-F QHE2X40DL/UNV ISN-SC QHE2X40DL/UNV ISN-SC QHE3X40DL/UNV ISN-SC QHE3X40DL/UNV ISN-SC Universal P/N T12 Fluorescent Ballasts Description HID Electronic Ballasts ICF-2S13-BE ICF-2S13-LD Advance P/N T5 Fluorescent Ballasts 71428 71429 71430 71432 71433 71434 71443 71444 71445 47506 47509 80683 80680 80681 80690 80691 87634 87533 87655 87700 87623 87625 Prod Code Description HID Electromagnetic Ballasts High Pressure Sodium T8 Fluorescent Ballasts Compact Fluorescent Ballasts Prod Code Quick Reference Guides gelighting.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2008:02:15 14:14:57-05:00 Modify Date : 2008:06:13 11:25:03-04:00 Metadata Date : 2008:06:13 11:25:03-04:00 Creator Tool : PScript5.dll Version 5.2.2 Document ID : uuid:02379240FADBDC118090A7F05934CEB7 Instance ID : uuid:26fd38f6-738b-491f-9a42-74d6da0fd528 Derived From Instance ID : uuid:6104ece2-28d5-401f-87a9-b126db55ba8e Derived From Document ID : uuid:d632b817-c811-4db6-988e-f72371d7dd7e Format : application/pdf Title : 2008 Ballast Cat Revised.pdf Creator : 211008578 Has XFA : No Page Count : 98 Author : 211008578EXIF Metadata provided by EXIF.tools