GE Consumer & Industrial
Lighting
GE Ballast Products Catalog 2008

ballasts
2008 product catalog

US/Canada Customer Ordering and Tracking—www.geelitenet.com
For detailed ballast and lamp specifications—www.gelighting.com
For order, technical or warranty assistance, call: 1-888-GEBALLAST (432-2552)
OEM Customer Service: (T) 1-800-833-4933, (F) 1-800-327-0588
GE Lighting Headquarters, Nela Park, 1975 Noble Rd., Cleveland, OH 44112, (T) 216-266-2121

Transforming
the POWER
of light™

GE has a policy of continuous improvement of its products and reserves the
right to change materials and specifications without notice.
© 2007 GE Company
Pub. No. 71883 PC48878

Transforming
the POWER
of light™

gelighting.com

GE Consumer & Industrial
Lighting
GE Consumer & Industrial
Lighting

The future can seem pretty intimidating: Our known reserves of oil and natural gas are expected to be
depleted by 2045, the climate is changing, and more than a billion people lack clean water. At GE, we
believe some of the world’s most pressing challenges present an opportunity to do what we do best:
Imagine and build innovative solutions that benefit our customers and society at large.
As a global leader in energy, technology, manufacturing and infrastructure, GE is uniquely suited to
help solve environmental challenges, today and for generations to come. Our customers want a more
prosperous, cleaner future. By harnessing our most abundant renewable resource—the imagination
of our people—we can create that future with them. We are taking a new approach to solving some of
our customers’ toughest environmental problems.

We call it ecomagination.

GE Ultra High Efficiency
Design is Ultra Cool!

Product Warranties

Results:
Combine GE’s Ultra ballasts with
cool running fixtures to achieve
maximum system performance in
hot temperatures. GE provides the
Ultra Cool™ system certification
with high grade fixture systems
which means a 5 year 55°C max
ambient warranty.

Light your world with a brand
you can trust—GE.

sm

Impact of ecomagination:
A manufacturing and warehouse facility was looking to reduce costs and greenhouse gas emissions:

Existing Lighting
400W MH std. CWA
Light output*
Size
Energy Rate/Burning Hours
Total Watts per Fixture
Energy Used
RoHS compliant**

23,000 mean lumens at 8,000 hours (19,200 lumens at 12,000 hours)
100,000 sq. ft. – 300 fixtures
10¢ kWh/5,000 per year
458
$68,700
No

Proposed Lighting
4-Lamp T5WM HO with UltraStart® Ballast
Light output*
19,000 mean lumens at 12,000 hours
Watts per Fixture
216
Energy Used
$32,400
Energy Saved
$36,300
RoHS compliant**
Yes

If your GE lamp or ballast, when installed and used properly, fails during
its warranty period because of defects in materials or workmanship, our
warranties provide for purchase price credits or replacement. Of course,
every lamp, ballast and system is different and warranty details vary,
so check the individual warranty for your product at
http://genet.gelighting.com/LightProducts/html/warranties.htm.

Environmental Impact
Watts Saved
Greenhouse gases (Co2)
SO2
The equivalent effect of:
Equivalent Forestation
Equivalent Cars

363,000 kilowatt-hours per year
Reduced by 519,090 lbs. per year
Reduced by 2,030 lbs. per year
71 acres
45 cars removed from the roads for a year

System Limited Warranty
GE Lamps operating on GE Ballast

Our heritage, our future
We believe that better technology is the answer to our customers’ environmental challenges. And we
are confident we can find tomorrow’s solutions to those challenges just as we have since the days of
our founder, Thomas Edison.
Throughout our 115-year history, we have invented solutions to meet our customers’ greatest needs.
Over many years, we have developed one of the broadest ranges of environmentally advanced
technologies. We will build on this legacy of success by researching and developing next-generation
clean technologies. Our goal is to be a leader in bringing clean energy, air, water and improved quality
of life to all of the world’s citizens.

*Mean lumen measured at 40% of rated life
**RoHS compliant: European Directive
(2002/95EC on the Restriction of Hazardous
Substances) states that (beyond certain
limited exemptions) electrical and
electronic products shall not contain lead,
cadmium, mercury, hexavalent chromium,
polybrominated biphenyls (PBBs), or
polybrominated diphenyl ethers (PBDEs).
GE’s UltraStart® ballasts use lead-free
solder and other environmentally preferable
materials that meet the RoHS directive.
RoHS-compliant ballasts are GE’s
commitment to helping our customers meet
their disposal needs now, and in the future.

2

GE has been a leader in innovative lighting technologies for over 100 years.
Our name on the label is virtually synonymous with dependable, efficient,
high-quality products—and that is why we are totally confident in the
system performance and reliability of our lamps and ballasts. Also it is why
we are willing to back them with a limited warranty that provides excellent
coverage against defects in materials and workmanship.

Compact Fluorescent Lamp
Double Biax®: 13-, 18-, 26-watt 4-pin base
Triple Biax®: 13-, 18-, 26-, 32-, 42-watt
2D®: 10-, 16-, 21-, 28-, 38-watt

Warranty *
1 year after date of purchase or 4000 hrs.
1 year after date of purchase or 4000 hrs.
1 year after date of purchase or 4000 hrs.

Electronic Ballast Warranty
5 years from date of manufacture
5 years from date of manufacture
5 years from date of manufacture

Electromagnetic Ballast Warranty
2 years from date of manufacture
2 years from date of manufacture
2 years from date of manufacture

Linear Fluorescent Lamp

Warranty

Electronic Ballast Warranty

Electromagnetic Ballast Warranty

F25T12**
F28T8, F32T8, F32T8WM
F32T8/XL, F32T8/XL/HL, F32T8/XL/WM
F32T8 SXL, F32T8/25W
F14T5HE, F21T5HE, F28T5HE,
F35T5HE, F54T5HO
F14T5/WM, F21T5/WM, F28T5/WM,
F35T5/WM, F54T5/WM
F28WT5/HL
F96T8
F96T8/XL, F96T8/XL/WM. F96T8/XL/WMP

3 years after date of purchase or 10,500 hrs.
3 years after date of purchase or 10,500 hrs.
3 years after date of purchase or 12,500 hrs.
4.5 years after date of purchase or 15,750 hrs.
4 years after date of purchase or 14,000 hrs.

5 years from date of manufacture
5 years from date of manufacture
5 years from date of manufacture
5 years from date of manufacture
5 years from date of manufacture

2 years from date of manufacture

3.5 years after date of purchase or 12,500 hrs.

5 years from date of manufacture

3 years after date of purchase or 10,500 hrs.
2 years after date of purchase or 8,000 hrs.
3 years after date of purchase or 10,500 hrs.

5 years from date of manufacture
5 years from date of manufacture
5 years from date of manufacture

HID Lamp
Warranty
Electronic Ballast Warranty
Electromagnetic Ballast Warranty
CMH® ConstantColor® SPXX 250-, 320-,
1 year after date of purchase or 5000 hrs.
5 years from date of manufacture
350-, 400-watt
PulseArc® 250-, 320-, 350-, 400-watt
1 year after date of purchase or 5000 hrs.
5 years from date of manufacture
*Based on whichever comes first
®
®
®
**On GE Normal light output UltraMax , ProLine or Multivolt Proline instant start ballasts
***See warranties at gelighting.com for specific lamp cycle requirements for instant start & program start ballasts. Cycle time with program start ballasts shall be 15
minutes or greater
****All covRguard® lamps are included

195

Quick Reference
Guides

gelighting.com

Table of contents
4 Product overview
6 Quick reference ballast selection guide
16 Quick reference lamp to ballast selection guide

T8
Fluorescent Ballasts

PRODUCTS
Sign Ballasts

36 Understanding T8 Fluorescent Ballasts
T8 INSTANT START BALLASTS
38 UltraMax® Instant Start Multi-Voltage High Efficiency
38 For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
45 For 46 – 59W 4 ft–8 ft Slimline Lamps
46 ProLine® T8 Multivolt 120V–277V
46 For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
51 For 46 – 59W 4 ft–8 ft Slimline Lamps
52 ProLine® T8 Multivolt, High Output 120V–277V
52 For 44 – 86W 4 ft–8 ft High Output Lamps
53 ProLine® T8 Instant Start High Performance
53 For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
57 For 46 – 59W 4 ft–8 ft Slimline Lamps
58 Residential Grade ProLine® T8 120V
58 For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
59 Electromagnetic T8 Ballasts
59 For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
T8 PROGRAMMED START BALLASTS
60 UltraStart® T8 Programmed Start
60 For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
69 T8 Dimming
69 For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
72 Wiring Diagrams
75 Case Dimensions

106 Understanding Sign Ballasts
107 Sign Ballasts
107 For T12 High Output Lamps
115 Wiring Diagrams
119 Case Dimensions
120 Understanding Compact Fluorescent Ballasts
123 ProLine® CFL Electronic Ballasts
123 For 13 – 42W T4 CFL Lamps
125 For 40W Biax® CFL Ballasts
128 For 5 – 26W Preheat CFL Lamps
129 CFL Magnetic Ballasts
129 For 5 - 26W Preheat CFL Lamps
130 For 36 – 40W CFL Lamps
131 Wiring Diagrams
133 Case Dimensions

T5 Fluorescent Ballasts

HID Electromagnetic Ballasts

76 Understanding T5 Electronic Programmed Start Ballasts
T5 ELECTRONIC PROGRAMMED START BALLASTS
77 T5 High Efficiency Programmed Start
77 For F14 (2 ft), F21 (3 ft), F28 (4 ft), F35 (5 ft) HE T5 Lamps
79 T5 High Output Programmed Start
79 For F24 (2 ft), F39 (3 ft), F54 (4 ft), F80 (5 ft) HO T5 Lamps
82 Wiring Diagrams
83 Case Dimensions

142 Understanding Electromagnetic HID Ballasts
144 Metal Halide
144 For 20 – 175W Metal Halide HID Lamps
149 For 250 – 1500W Metal Halide HID Lamps
155 Pulse Start
155 For 175 – 1000W Pulse Start Metal Halide HID Lamps
162 High Pressure Sodium
162 For 50 – 150W High Pressure Sodium HID Lamps
166 For 250 – 1000W High Pressure Sodium HID Lamps
170 High Intensity Discharge Lamp Ballast Kits
174 Enclosed and Potted Metal Halide
178 F-Can and Post Mount High Pressure Sodium
HID ACCESSORIES
179 Replacement Capacitors
179 Replacement Ignitors for Pulse Start Lamps (MH & HPS)
179 Other Accessories
180 Wiring Diagrams
184 Case Dimensions

134 Understanding Electronic UltraMax® HID Ballasts
135 Electronic HID
135 For 20 – 150W Pulse Start HID Lamps
139 For 250 – 400W Pulse Start HID Lamps
140 Wiring Diagrams
141 Case Dimensions

Glossary
Ballast Cross Reference Matrix
Contact Information
Warranty Information

HID Electronic
Ballasts

186
190
194
195

Compact Fluorescent
Ballasts
3

HID Electromagnetic
Ballasts

84 Understanding T12 Electronic Ballasts
T12 ELECTRONIC BALLASTS
85 ProLine® T12 Multivolt 120V–277V
85 For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps
87 For T12 (4 ft–8 ft) Slimline Lamps
T12 HIGH OUTPUT BALLASTS
88 For T12 High Output Lamps
T12 MAGNETIC BALLASTS
90 For 2 ft, Circleline, Preheat T12 Lamps
93 For F30, F34/F40 (4 ft) T12 Lamps
97 For T12 4 ft–8 ft Slimline Lamps
99 For T12 High Output Lamps
FLUORESCENT ACCESSORIES
100 Starters
100 Sockets
101 Wiring Diagrams
104 Case Dimensions

HID Electronic Ballasts

Sign
Ballasts

T12 Electronic Ballasts

T12
Fluorescent Ballasts

T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in
feet. See GE Lamp Catalog for exact lamp length.

Compact Fluorescent Ballasts
T5
Fluorescent Ballasts

Inside front cover is in cover file

T8 Fluorescent Ballasts

gelighting.com

2008 Ballast Product Catalog
This catalog contains North

Ecomagination is GE’s commitment to create products that

America ballast and lamp

help our customers improve their environmental and operating

data as of December 2007.

performance. GE’s UltraStart® T5 and T8 programmed start and

Additional information is

GE UltraMax® Instant Start ballasts are among the highest

constantly being uncovered

energy-efficient ballasts available and contribute to significant

through research and testing,

reductions in energy consumption and the curbing of

which may modify the

greenhouse gas emissions.

SM

UltraMax® T8 Electronic Ballast

UltraStart® T8 Electronic Ballast

data given herein. Changes
may be made at any time.

RoHS compliant:

ProLine® Electronic Ballast

The data and suggested

European Directive (2002/95EC on the Restriction of
Hazardous Substances) states that (beyond certain limited
exemptions) electrical and electronic products shall not
contain lead, cadmium, mercury, hexavalent chromium,
polybrominated biphenyls (PBBs), or polybrominated diphenyl
ethers (PBDEs). GE’s electronic ballasts use lead-free solder and
other environmentally preferable materials that meet the RoHS
directive. Although not required in the U.S., RoHS-compliant
ballasts show GE’s commitment to helping our customers meet
their disposal needs now, and in the future. GE encourages
customer awareness on the importance of reducing hazardous
materials and getting ahead of complying with environmental
trends. Look for the RoHS-compliant mark on GE ballasts.

Offered in dedicated or multivolt (120-277V), these highperformance T8 instant start ballasts are long life, less than
10% THD and most models also meet minimum efficiency
requirements of the NEMA Premium® ballast program.

UltraMax® Electronic Ballast

Electromagnetic Ballast (Magnetic Ballast)

applications should not be
taken as representations
or warranties as to the
suitability of a ballast for a
particular application.

A family of high-efficiency GE T8 instant-start electronic linear
fluorescent ballasts designed to optimize GE’s T8 Ultra lamps
for optimal system energy savings. UltraMax® ballasts have
a lamp-friendly low-lamp-current crest factor and virtually
“read” and adapt to incoming voltage from 108V to 305V. Other
features include UL Type CC Anti-Arc Rating and anti-striation
control to eliminate lamp striations and spiraling. All UltraMax®
ballasts exceed 90% efficiency and the NEMA Premium® ballast
program minimum efficiency requirements.

UltraStart® Electronic Ballast
UltraStart® ballasts are a family of high-efficiency GE
Program Start (see page 36) electronic linear fluorescent
ballasts designed to optimize GE’s T8 and T5 Ultra lamps in
frequently switched applications. Instant Start ballasts provide
approximately 10,000 starts before 50% of lamp failure.
UltraStart® provides greater than 100,000 starts. UltraStart®
have the equivalent energy savings and convenience of
instant start ballasts but with the long lamp life of a
programmed start ballast.
UltraStart® T8 L, N and H ballasts exceed 90% efficiency and
the NEMA Premium® ballast program minimum efficiency
requirements.

4

Compact Fluorescent Lamp (CFL)
CFLs are single-ended T4 and T5 lamps that are bent to form
a compact shape. Screw-in CFLs have an integral ballast with
a screw base for easy replacement of incandescent lamps. GE
offers multi-voltage, multi-lamp and multi-entry ballasts for a
wide range of CFL plug-in lamps. Multivolt ProLine® CFL ballasts
are designed for plug-in lamps so that a ballast will survive over
the useful life of approximately 3-to-4 lamp lives.

Primarily used for T12 lamps. These ballasts operate lamps at
a less efficient 60Hz and typically have efficiencies of 70-80%.
Most ballasts consist of a core and coil transformer assembly.
Today, magnetic ballasts for 4 foot and 8 foot lamps are typically
used only for replacement purposes and are restricted by EPACT
to be sold, even in replacement applications, starting in 2009.

Multivolt ProLine® CFL Ballast

Sign Ballast

Sign Ballast (Magnetic Ballast)
Designed to operate T12 HO Lamps at 120 volts in cold and
damp conditions in sign cabinets.

GE eHID, Electronic High Intensity
Discharge Ballast (eHID)
Electronic HID significantly improves the performance of HID
lighting. GE’s UltraMax® eHID ballast operates pulse start and
ceramic metal halide lamps.

HID Electromagnetic Ballast Kit

GE High Intensity Discharge Ballast (HID)
HID magnetic ballasts consist of robust core and coil designs
that meet or exceed minimum ANSI requirements. These
ballasts are typically sold as distributor replacement kits which
are pre-wired with a capacitor, ignitor (if applicable) and all
necessary mounting hardware and instructions. Each wattage
is typically offered in quad (MLT-120/208/240/277 volt), 5-tap
(ML5-120/208/240/277/480 volt) or 480 volt (48T) options.

UltraMax® eHID Ballast

5

Quick Reference
Guides

gelighting.com

Quick reference ballast selection guide
Application

Product Page
Number
Pallet Pack

DIY Pack

Std Pack
Units Per
Carton

T8 Fluorescent Ballasts
UltraMax® Instant-Start Multi-Voltage High-Efficiency

DIY Pack

Std Pack
Units Per
Carton

38
38
39
39
40
40
41
41
42
42
43
43
44
44

72260
47548
72256
72267
71715
71718
71721
71724
71726
71729

72268

71722

71730

10
10
10
10
10
10
10
10
10
10
10
10
10
10

71037
71038

10
10

GE-232-277-PS-N

96714

GE232-MVPS-N

GE-232-MVPS-XL

29623

GE-332-120-PS-N

29624

GE-332-277-PS-N

29676

GE-332-MVPS-H

96715

GE332-MVPS-N

96721

GE332-MVPS-L

29672

GE-332-MVPS-XL

29625

GE-432-120-PS-N

29627

GE-432-277-PS-N

96716

GE432-MVPS-N

71832

GE432-MVPS-L

29678

GE-432-MVPS-H

30274
30272

97711

97712

10
10

72277

97710

30187

10

ProLine T8 Instant-Start High-Performance
10
10
10
10
10
10
10
10

57
57

24169
24170

10
10

See page 195 for warranty information.

10

60

29632

10

61

96717

10

61

10

62

29651

10

62

29665

10

63

29633

10

63

29634

10

64

29656

10

64

96718

10

65

10

65

29666

10

66

29635

10

66

29650

10

67

96719

10

67
68

10
29657

8

T8 Dimming
For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
80353
B132R120V5
80355
B232SR120V5
80362
B232SR277S50
80356
B232SR277V5
80357
B332SR120V5
80358
B332SR277V5

See page 195 for warranty information.

1 – F32T8 DIM 100 to 5% RS 120
2 – F32T8 DIM 100 to 5% RS 120
2 – F32T8 Switch 100/50% RS 277
2 – F32T8 DIM 100 to 5% RS 277
3 – F32T8 DIM 100 to 5% RS 120
3 – F32T8 DIM 100 to 5% RS 277

69
69
70
70
71
71

10
10
10
10
10
10

7

HID Electromagnetic
Ballasts

24161
24162
24163
24164
24165
24166
24167
24168

29630

HID Electronic
Ballasts

53
53
54
54
55
55
56
56

60

Compact Fluorescent
Ballasts

29671

2 – F32T8 120V Normal Light .87 BF <10% THD
UltraStart®
2 – F32T8 277V Normal Light .87 BF <10% THD
UltraStart®
2 or 1 – F32T8 120V-277V Normal Light .88 BF
<10% THD UltraStart®
2 or 1 – F32T8 120V-277V Low Watts .71 BF
<10% THD UltraStart®
2 – F32T8 120V-277V High Light 1.15 BF <10%
THD UltraStart®
2 – F32T8 120V-277V Ultra Low Watt .60 BF
<10% THD
3 – F32T8 120V Normal Light .87 BF <10% THD
UltraStart®
3 – F32T8 277V Normal Light .87 BF <10% THD
UltraStart®
3 – F32T8 120V-277V High Light 1.15 BF <10%
THD UltraStart®
3 – F32T8 120V-277V Normal Light .88 BF <10%
THD UltraStart®
3 – F32T8 120V-277V Low Watts .71 BF <10%
THD UltraStart®
3 – F32T8 120V-277V Ultra Low Watt .60 BF
<10% THD
4 – F32T8 120V Normal Light .87 BF <10% THD
UltraStart®
4 – F32T8 277V Normal Light .87 BF <10% THD
UltraStart®
4 – F32T8 120V-277V Normal Light .88 BF <10%
THD UltraStart®
4 – F32T8 120V-277V Low Watts .71 BF <10%
THD UltraStart®
4 – F32T8 120V-277V High Light 1.15 BF <10%
THD UltraStart®

Sign
Ballasts

10
10

10
10
10
10
10
10
10
10
10
10

10
10

T12
Fluorescent Ballasts

29622

GE-232-MVPS-H

®

For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
23680
GE-132-120-N
1 – F32T8 120V “N”.87 BF ProLine®
23681
GE-132-277-N
1 – F32T8 277V “N”.87 BF ProLine®
23671
GE-232-120-N
2 or 1 – F32T8 120V “N”.87 BF ProLine®
23672
GE-232-277-N
2 or 1 – F32T8 277V “N”.87 BF ProLine®
23673
GE-332-120-N
3 or 2 – F32T8 120V “N”.87 BF ProLine®
23674
GE-332-277-N
3 or 2 – F32T8 277V “N”.87 BF ProLine®
23675
GE-432-120-N
4 or 3 – F32T8 120V “N”.87 BF ProLine®
23676
GE-432-277-N
4 or 3 – F32T8 277V “N”.87 BF ProLine®
For 46 – 59W 4 ft – 8 ft Slimline Lamps
23677
GE-259-120-N
2 or 1 – F96T8 120V Normal Light .87 BF ProLine®
23678
GE-259-277-N
2 or 1 – F96T8 277V “N”.87 BF ProLine®

GE-232-120-PS-N

29675

51
51

52

29621

10

72270
30275
72274
72276
30296
30309
30270
30303
30310
30271

59
59

For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps

71502

46
46
47
47
48
48
49
49
50
50

2 – F32T8 RS 120V Magnetic Ballast
2 – F32T8 RS 277V Magnetic Ballast

UltraStart® T8 Programmed Start

GE232-MVPS-L

23954

58
58

T8 PROGRAMMED START BALLASTS

96720

ProLine® T8 Multivolt High Output 120V – 277V
2 or 1 – F96T8HO IS 120 to 277 “N”.87 BF

For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
87125
GEM232T8RS120
87130
GEM232T8RS277

10

45
45

2 or 1 – F32T8 120V “N”.87 BF Residential ProLine®
4 or 3 – F32T8 120V “N”.87 BF Residential ProLine®

Electromagnetic T8 Ballasts

71732

ProLine® T8 Multivolt 120V – 277V
For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
72269
GE-132-MV-N
1 – F32T8 120 to 277 “N”.87 BF MV ProLine®
30198
GE-232-MV-H
2 or 1 – F32T8 120 to 277 “H” 1.18 BF MV ProLine®
72273
GE-232-MV-L
2 or 1 – F32T8 120 to 277 “L”.77 BF MV ProLine®
72275
GE-232-MV-N
2 or 1 – F32T8 120 to 277 “N”.87 BF MV ProLine®
30199
GE-332-MV-H
3 or 2 – F32T8 120 to 277 “H” 1.15 BF MV ProLine®
30255
GE-332-MV-L
3 or 2 – F32T8 120 to 277 “L” .77 BF MV ProLine®
30192
GE-332-MV-N
3 or 2 – F32T8 120 to 277 “N”.87 BF MV ProLine®
30219
GE-432-MV-H
4 or 3 – F32T8 120 to 277 “H” 1.15 BF MV ProLine®
30262
GE-432-MV-L
4 or 3 – F32T8 120 to 277 “L” .77 BF MV ProLine®
30193
GE-432-MV-N
4 or 3 – F32T8 120 to 277 “N”.87 BF MV ProLine®
For 46 – 59W 4 ft – 8 ft Slimline Lamps
30195
GE-159-MV-N
1 – F96T8 120 to 277 “N”.87 BF MV ProLine®
30194
GE-259-MV-N
2 or 1 – F96T8 120 to 277 “N”.87 BF MV ProLine®

For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
97782
GE232-120-RES
97783
GE432-120-RES

T5
Fluorescent Ballasts

For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
72258
GE132MAX-L/ULTRA
1 – F32T8 120 to 277 “L” .77 BF UltraMax®
72259
GE132MAX-N/ULTRA
1 – F32T8 120 to 277 “N” .87 BF UltraMax®
49775
GE232MAX-H/ULTRA
2 or 1 – F32T8 120 to 277 “H” 1.15 BF UltraMax®
72262
GE232MAX-L/ULTRA
2 or 1 – F32T8 120 to 277 “L” .77 BF UltraMax®
72266
GE232MAX-N/ULTRA
2 or 1 – F32T8 120 to 277 “N” .87 BF UltraMax®
71421
GE232MAX-N+
2 or 1 – F32T8 120 to 277 “N+” 1.0 BF UltraMax®
71714
GE332MAX-H/ULTRA
3 or 2 – F32T8 120 to 277 “H” 1.18 BF UltraMax®
71717
GE332MAX-L/ULTRA
3 or 2 – F32T8 120 to 277 “L” .77 BF UltraMax®
71719
GE332MAX-N/ULTRA
3 or 2 – F32T8 120 to 277 “N” .87 BF UltraMax®
71422
GE332MAX-N+
3 or 2 – F32T8 120 to 277 “N+” 1.0 BF UltraMax®
71723
GE432MAX-H/ULTRA
4 or 3 – F32T8 120 to 277 “H” 1.18 BF UltraMax®
71725
GE432MAX-L/ULTRA
4 or 3 – F32T8 120 to 277 “L” .77 BF UltraMax®
71727
GE432MAX-N/ULTRA
4 or 3 – F32T8 120 to 277 “N” .87 BF UltraMax®
71423
GE432MAX-N+
4 or 3 – F32T8 120 to 277 “N+” 1.0 BF UltraMax®
6, 5, 4 – F32T8 120 to 277 “H” BF UltraMax® 0-10V
100-60% continuous dim
71731
GE632MAX-H90-V60
6, 5, 4 – F32T8 120 to 277 “H” BF UltraMax® 95%
71497
GE632MAX-H90-S60
100/60% step dim
For 46 – 59W 4 ft – 8 ft Slimline Lamps
49766
GE159MAX-N/ULTRA
1 – F96T8 120 to 277 “N” .87 BF UltraMax®
49767
GE259MAX-N/ULTRA
2 or 1 – F96T8 120 to 277 “N” .87 BF UltraMax®

6

Application

Product Page
Number
Pallet Pack

T8 Fluorescent Ballasts
Residential Grade ProLine® T8 120V

T8 INSTANT START BALLASTS

For 44 – 86W 4 ft – 8 ft HO Lamps
30176
GE-286-HO-MV-N

Std Pack
Prod Code Description

T8
Fluorescent Ballasts

Std Pack
Prod Code Description

Quick Reference
Guides

gelighting.com

Quick reference ballast selection guide (cont.)

T5 ELECTRONIC PROGRAMMED START BALLASTS

Prod Code
New

Description (Same)

Application

72258
72259
72260
72262
72263
72264
72265
72266
72267
72268
71714
71715
71717
71718
71720
71719
71721
71722
71723
71724
71725
71726
71728
71727
71729
71730

GE132MAX-L/ULTRA
GE132MAX-N/ULTRA
GE132MAX-N-DIY
GE232MAX-L/ULTRA
GE232MAX-L-42T
GE232MAX-N/AMP
GE232MAX-N/CTR
GE232MAX-N/ULTRA
GE232MAX-N-42T
GE232MAX-N-DIY
GE332MAX-H/ULTRA
GE332MAX-H-42T
GE332MAX-L/ULTRA
GE332MAX-L-42T
GE332MAX-N/CTR
GE332MAX-N/ULTRA
GE332MAX-N-42T
GE332MAX-N-DIY
GE432MAX-H/ULTRA
GE432MAX-H-42T
GE432MAX-L/ULTRA
GE432MAX-L-42T
GE432MAX-N/CTR
GE432MAX-N/ULTRA
GE432MAX-N-42T
GE432MAX-N-DIY

1- F32T8 120 to 277 “L” .77BF UltraMax®
1- F32T8 120 to 277”N” .87 BF UltraMax®
1- F32T8 120 to 277”N” .87 BF UltraMax® DIY Pack
2 or 1- F32T8 120 to 277 “L” .77 BF UltraMax®
2 or 1- F32T8 120 to 277 “L” .77 BF UltraMax® Pallet Pack
2 or 1- F32T8 120 to 277 “N” .87 BF UltraMax® w/ AMP Connectors
2 or 1- F32T8 120 to 277 “N” .87 BF UltraMax® w/ JST Connectors
2 or 1- F32T8 120 to 277 “N” .87 BF UltraMax®
2 or 1- F32T8 120 to 277 “N” .87 BF UltraMax® Pallet Pack
2 or 1- F32T8 120 to 277 “N” .87 BF UltraMax® DIY Pack
3 or 2- F32T8 120 to 277 “H” 1.18 BF UltraMax®
3 or 2- F32T8 120 to 277 “H” 1.18 BF UltraMax® Pallet Pack
3 or 2- F32T8 120 to 277 “L” .77 BF UltraMax®
3 or 2- F32T8 120 to 277 “L” .77 BF UltraMax® Pallet Pack
3 or 2- F32T8 120 to 277 “N” .87 BF UltraMax® w/ JST Connectors
3 or 2- F32T8 120 to 277 “N” .87 BF UltraMax®
3 or 2- F32T8 120 to 277 “N” .87 BF UltraMax® Pallet Pack
3 or 2- F32T8 120 to 277 “N” .87 BF UltraMax® DIY Pack
4 or 3- F32T8 120 to 277 “H” 1.18 BF UltraMax®
4 or 3- F32T8 120 to 277 “H” 1.18 BF UltraMax® Pallet Pack
4 or 3- F32T8 120 to 277 “L” .77 BF UltraMax®
4 or 3- F32T8 120 to 277 “L” .77 BF UltraMax® Pallet Pack
4 or 3- F32T8 120 to 277 “N” .87 BF UltraMax® w/ JST Connectors
4 or 3- F32T8 120 to 277 “N” .87 BF UltraMax®
4 or 3- F32T8 120 to 277 “N” .87 BF UltraMax® Pallet Pack
4 or 3- F32T8 120 to 277 “N” .87 BF UltraMax® DIY Pack

10
10
4
10
420
10
10
10
420
10
10
420
10
420
10
10
420
4
10
420
10
420
10
10
420
4

39

40

41
41

42

43
43

44

®

ProLine T8 Multivolt 120-277V
72269
72270
72273
72274
72275
72276
72277

GE-132-MV-N
GE-132-MV-N-42T
GE-232-MV-L
GE-232-MV-L-42T
GE-232-MV-N
GE-232-MV-N-42T
GE232MV-N-DIY

1- F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
1- F32T8 120 to 277 “N”.87 BF Multivolt ProLine® Pallet Pack
2 or 1- F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1- F32T8 120 to 277 “L”.77 BF Multivolt ProLine® Pallet Pack
2 or 1- F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1- F32T8 120 to 277 “N”.87 BF Multivolt ProLine® Pallet Pack
2 or 1- F32T8 120 to 277 “N”.87 BF Multivolt ProLine® Pallet Pack DIY Pack

46
47
47

10
420
10
420
10
420
4

77

99654

10

77
78

99656

10
10

T5 High Output Programmed Start
For F24 (2 ft), F39 (3 ft), F54 (4 ft), F80 (5 ft) HO T5 Lamps
47534
B224PUNV-COG1C
2 – F24T5HO PRS UNV 50/60 Hz C Can
79
47540
B239PUNV-DOG1C
2 – F39T5HO PRS UNV 50/60 Hz D Can
79
2 or 1 – F54T5HO 120 to 277 UltraStart® PRS High
99651
GE254MVPS90-F
Temp F Can
80
99652
47542
B254PUNV-DGE1C
2 – F54T5HO PRS UNV 50/60 Hz D Can
80
72279
GE254MVPS-D
2 or 1 – F54T5HO 120 to 277 UltraStart® PRS D Can
4-1 – F54T5HO 120 to 277 UltraStart® PRS High
99649
GE454MVPS90-E
Temp E Can
81
99650
4,3,2, or 1 – F54T5HO 120-277V UltraStart® PRS
Can
81
29717
GE454MVPSN1
29726
72280
GE180MVPS-D
1 – F80T5HO 120 to 277 UltraStart® PRS D Can
T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length.

10
10
10
10
10
8
12
10

T12 Fluorescent Ballasts

T12 ELECTRONIC BALLASTS
ProLine® T12 Multivolt 120V – 277V
For F20 (2 ft), F30 (3 ft), and F34/F40 (4 ft) T12 Lamps
2 or 1 – F40 or F34T12 Rapid Start 120 to 277 “N”
24107
GE-240-RS-MV-N
BF ProLine® T12
2 – F40 or F34T12 Rapid Start 120V “N” BF
97498
GE240RS120
ProLine® T12
1 – F40 or F34T12 Rapid Start Electronic 120V “N”
72110
GE140RS120-DIY
BF DIY Pack
3 or 2 – F40 or F34T12 Rapid Start 120 to 277
24109
GE-340-RS-MV-N
ProLine® T12
For T12 4 ft – 8 ft Slimline Lamps
24108
GE-260-IS-MV-N
2 or 1 – F96T12 Instant Start 120 to 277

85

24773

10

85

97499

10

86

72110

86

24774

10

87

24776

10

Compact Fluorescent
Ballasts

30189
30268
30247
30308
30191
30269
97709

For F14 (2 ft), F21 (3 ft), F28 (4 ft), F35 (5 ft) HE T5 Lamps
2 or 1 – F14-F28T5HE 120 to 277 UltraStart® PRS
99653
GE228MVPSH-A
High Light 1.15 BF A Can
2 or 1 – F14-F35T5HE 120 to 277 UltraStart® PRS
Normal Light .95 BF A Can
99655
GE228MVPS-A
47536
B228PUNV-C0G1C
2 – F28T5 PRS UNV 50/60 Hz C Can

Sign
Ballasts

38
38

UltraMax Instant-Start Multi-Voltage High-Efficiency

T5 High Efficiency Programmed Start

T12
Fluorescent Ballasts

Units Per
Carton

T5
Fluorescent Ballasts

Product Page
Number

®

49706
49771
23939
49707
47546
71281
97656
49772
31052
23940
49776
47549
49708
31055
97657
49773
31053
23941
49777
47550
49709
47547
97658
49774
31054
23942

DIY Pack

Std Pack
Units Per
Carton

T5 Fluorescent Ballasts

T8 Fluorescent Ballasts
2008 T8 Ballast Enhancement New Product Code Cross Reference
Existing

Application

Product Page
Number
Pallet Pack

T8
Fluorescent Ballasts

Std Pack
Prod Code Description

T12 HIGH OUTPUT
80162
80163

B295SR120HP
B295SR277HP

72109

GE296HO-MV-N

2 – F96T12HOES RS 120
2 – F96T12HOES RS 277
2 or 1 – F96T12 HO RS 120 to 277 Multivolt
ProLine®

88
88

6
6

89

T12 MAGNETIC BALLASTS
For 2 ft, Circleline, Preheat T12 Lamps

89712

GEM120TC120DIY

89720

GEM1FC16T9RS120

86227

GEM1FC8T9RS120IP

89717

GEM1FC12T9RS120

80819

GEM220TS120DIY

See page 195 for warranty information.

1 – F20T12, F15T8, F1512, F14T8, F18T8, 120V
Magnetic Ballast (200H2)
1 – F20T12, F15T8, F15T12, F14T12, 120V
Magnetic Ballast (546BTCP)
2 – FC12T9, FC16T9, FC8T9, FC12T9, 120V
Magnetic (726VLHWSTCP)
1 – FC8T9, FC6T9 RS 120V Magnetic Ballast
(547RSWSTCP)
2 FC12T9 RS 120V Magnetic Ballast
(449LRWSTCP)
2– F20T12, F15T8, F15T12, F14T12, 120V
Magnetic Ballast (447LRVLHTCP)

90

89711

10

90

89712

4

91

89720

4

91

89722

10

92

89717

92

80819

4

9

HID Electromagnetic
Ballasts

See page 195 for warranty information.

GEM120PH120DIY

HID Electronic
Ballasts

8

89711

Quick Reference
Guides

gelighting.com

Quick reference ballast selection guide (cont.)
Application

Product Page
Number
Pallet Pack

DIY Pack

Std Pack
Units Per
Carton

T12 Fluorescent Ballasts
GEM140HRS120DIY
GEM140RS120DIY
GEM230RS120DIY

89710

GEM240HRS120DIY

86139

GEM240RS120IP

86124

GEM240RS277IP

1 – F40T12, F40T12, 120V Magnetic Ballast
(412LSLHTCP)
1 – F40T12, F30T12, F48/25W, 120V Magnetic
Ballast (413CTCP)
2 – F30T12 120V Magnetic Ballast (573LTCP)
2 – F40T12, F40T12, 120V Magnetic Ballast
(420LTCP)
2 – F40T12 RS 120V Magnetic Ballast
(446LSLHTCP)
2 – F40T12 RS 277V Magnetic Ballast
(443LSLHTCP)
2 – F40T12, F40T10, 220V Magnetic Ballast
(754LTCP)

96

1 – F96T12 IS 120 Magnetic Ballast (822BRTCP)
1 – F96T12 IS 277 Magnetic Ballast (828BRTCP)
2 – F96T12 IS 120V Magnetic Ballast (806SLHTCP)
2 – F96T12 IS 277V Magnetic Ballast (827SLHTCP)

97
97
98
98

46965
89715

6
6
6
6

99

89718

4

93

89714

4

93
94

89709
80644

4
4

94

89710

4

95

46958

10

95

89713

10
10

86372

2 – F96T12HO, F96T8HO, F72T12HO RS 120V
Magnetic Ballast (480SLHTCP)
2 – F96T12HO, F96T8HO, RS 277V Magnetic
Ballast (487SLHTCP)
2 – F73T12/BL/HO Suntan 120 Magnetic Ballast

99
100

4
10

FS-2-C
FS-4-C
FS-5-C
FS-25-C
FS-12-C

Starters for 14, 15 & 20 Watt Flu. Lamps
Starters for 30 & 40 Watt Flu. Lamps
Starters for 4, 6 & 8 Watt Flu. Lamps
Starters for 22 & 25 Watt Flu. Lamps
Starters for 32 Watt Circular Flu. Lamps

100
100
100
100
100

24
24
24
24
24

BP-SKT
BP
SL-SS
BP-FM
BP-LP

Socket Set w/Starter for Bi-Pin Flu. Lamps
Socket Set for Bi-Pin Flu. Lamps
Socket Set for Slimline Flu. Lamps
Face Mount Socket Set for Bi-Pin Flu. Lamps
Low Profile Socket Set for Bi-Pin Flu. Lamps

100
100
100
100
100

12
12
12
12
12

T12HO Sign ballast, 4 to 12 ft, 1 to 2 lamps
T12HO Sign ballast 6 to 20 ft, 2 to 4 lamps
T12HO Sign ballast 12 to 24 ft, 2 to 4 lamps
T12HO Sign Ballast 12 to 40 ft, 4 to 6 lamps
T12HO Sign Ballast 20 to 40 ft, 4 to 6 lamps
T12HO Sign Ballast 24 to 48 ft, 4 to 6 lamps
4 to 12 ft, 1 to 2 lamps
08 to 16 ft, 1 to 4 lamps
16 to 32 ft, 2 to 4 lamps
10 to 24 ft, 1 to 4 lamps
20 to 36 ft, 4 to 6 lamps
20 to 48 ft, 4 to 6 lamps
Max 3, 02 to 18 ft, 1 to 6 lamps
Max 3, 10 to 48 ft, 1 to 6 lamps
Max 3, 12 to 32 ft, 1 to 6 lamps

107
107
108
108
109
109
110
110
111
111
112
112
113
113
114

1
1
1
1
1
1

86164

GEM296HORS120IP

86171
80664

GEM296HORS277IP
493B2

Units Per
Carton

FLUORESCENT ACCESSORIES

For 13 – 42W T4 CFL Lamps
71430

GEC213-MVPS-3W

71434

GEC218-MVPS-3W

71445 GEC226-MVPS-3W
47509 C242UNVSE-IP
For 40W Biax® CFL Ballasts
80683 C240PUNVHP-B-IP
80680 C240SI120RH-IP
80681 C240SI277RH-IP
80690 C340SI120RH-IP
80691 C340SI277RH-IP
For 5 – 26W Preheat CFL Lamps
87634 GEM1CF579PH277
87533 GEM1CF13PH120

2 or 1 - CFQ13W/G24q Bottom Exit 120-277V
ProLine® PS
2 or 1 - CFQ18W/G24q Bottom Exit 120-277
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit
120-277V ProLine® PS
2 - 42/36/32/26/24 watt CFLUNV side exit

123

71428

71429

71430

10

123

71432

71433

71434

10

124
124

71443

71444
47506

71445

10
10

2 or 1 – FT40W2G11 PS UNV
2 – FT40W/2G11 IS 120
2 – FT40W/2G11 IS 277
3 – FT40W/2G11 IS 120
3 – FT40W/2G11 IS 277

125
125
126
126
127

10
10
10
10
10

1 – CFT579Q9W/G23 Preheat 277 (4205F2P)
1 – CFT/Q13W/GX23 Preheat 120 (4111H2P)

128
128

20
20

2 – CFT/Q13W/GX23 Preheat 277 (4214PBES)
2 – CFQ26W/G24d Preheat 277 (4226PBES)

129
129

10
10

2 – FT36W/2G11 RS 120 (4150P)
2 – FT40W/2G11RS RS 120 (4152P)

130
130

10
10

T12
Fluorescent Ballasts

86341
GEM240RS220IP
For T12 4 ft – 8 ft Slimline Lamps
86372
GEM196IS120IP
86381
GEM196IS277IP
86360
GEM296IS120IP
86379
GEM296IS277IP
For T12 High Output Lamps

Application

T5
Fluorescent Ballasts

89709
80644

Description

Product
Dual Exit/
Page
Bottom Exit Bottom and 3-Way
Number with Studs
side
Mounting

Compact Fluorescent Ballasts
ProLine® CFL Electronic Ballasts

For F30, F34/F40 (4 ft) T12 Lamps
89714

Prod
Code

CFL Magnetic Ballasts
For 5 – 26W Preheat CFL Lamps
87655 GEM2CF13PH277
87700 GEM2CF24PH277
For 36 – 40W CFL Lamps
87623 GEM2FT36RS120
87625 GEM2FT40RS120

T8
Fluorescent Ballasts

Std Pack
Prod Code Description

Starters

Sign
Ballasts

80619
80620
80621
80622
80629

Sockets

Compact Fluorescent
Ballasts

80623
80624
80625
80627
80628

Sign Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

11

HID Electromagnetic
Ballasts

10

4
2
2
2
2
2
2
2

HID Electronic
Ballasts

For T12 High Output Lamps
72103
GESB-0412-12-IP
72104
GESB-0620-24-IP
72105
GESB-1224-24-IP
72106
GESB-1240-46-IP
72107
GESB-2040-24-IP
72108
GESB-2448-46-IP
88921
USB-0412-12-IP
88931
USB-0816-14-IP
88934
USB-1632-24-IP
88936
USB-1024-14-IP
88939
USB-2036-46-IP
88940
USB-2048-46-IP
88918
USB-0218-16-IP
88919
USB-1048-16-IP
88920
USB-1232-16-IP

Quick Reference
Guides

gelighting.com

Quick reference ballast selection guide (cont.)
Prod
Code

Description

Application

Product Page
Number

ANSI Lamp Type

Circuit Type

Units Per
Carton

For 20 – 150W Pulse Start HID Lamps
87490 GEMH20-MLF-120
87501 GEMH39-MSF-120
GEMH50-MSF-120

87531

GEMH70-MSF-120

87546

GEMH70-SLJ-MV

87561

GEMH100-SLJ-MV

87576 GEMH150-SLJ-MV
For 250W – 400W Pulse Start HID Lamps

GE-MH-250-400-MA

89646

GEMH250-400M-V50

1 – 250 to 400W UltraMax® HID
Dimming 208-277 50-60Hz

M156
M130

Electronic
Electronic

10
10

136

Electronic

10

Electronic

10

137

M148, M110, C148
M98, M143, M139,
C143, C139
M139, C139, M98,
M143, C143

Electronic

10

137

M90, M140, C140

Electronic

10

138

M142, M102, C142

Electronic

10

136

139

139

M155, M153, M138,
M135, M132, M131,
M154
M155, M154, M153,
M138, M135, M132,
M131

Electronic

1

Electronic

1

HID Electromagnetic Ballasts
Metal Halide
For 20 – 175W Metal Halide HID Lamps
M110

HX-HPF

6

M98
M98

HX-HPF
HX-HPF

6
6

145
146

M92, M90, M140
M92, M90, 40

HX-HPF
HX-HPF

6
6

146
147

M142, M102
M142, M102, M107

HX-HPF
HX-HPF

6
6

147

M57, H39, M109

CWA

6

148

M57, M107, H39

CWA

6

149

M58, H37

CWA

6

149

M58, H37

CWA

6

150

M58, H37

CWA

3

150

M59, H33

CWA

3

151
151
152

M59, H33
M59, H33
M47, H36

CWA
CWA
CWA

3
3
2

152

M47, H36

CWA

2

153
153

M47, H36
M48

CWA
CWA

2
2

154

M48

CWA

2

155
155

M153, M137
M152, M137

CWA
CWA

6
6

156
156

M153, M138
M153, M138

CWA
CWA

3
3

157
157

M154, M132
M154, M132

CWA
CWA

3
3

158

M154, M132

CWA

3

158
159

M131
M155, M135

CWA
CWA

3
3

159
160

M155, M135
M149

CWA
CWA

3
2

160

M149

CWA

2

161

M141

CWA

2

161

M141

CWA

2

162

S68

HX-HPF

6

162
163

S62
S62

HX-HPF
HX-HPF

6
6

163
164

S54
S54

HX-HPF
HX-HPF

6
6

164
165

S55
S55

HX-HPF
HX-HPF

6
6

166

S50

CWA

3

166

S50

CWA

3

167

S51

CWA

3

167

S51

CWA

3

168
168

S51
S52

CWA
CWA

3
2

169

S52

CWA

2

169

S52

CWA

2

HID Electromagnetic Ballasts
Pulse Start
For 175 – 1000W Pulse Start Metal Halide HID Lamps
1 – 175W PS M137 or M152 Quad
86885 GEP175MLTAC3-5
(120/208/240/277V)
86876 GEP17548TAC3-5
1 – 175W PS M137 or M152 480
1 – 250W PS M138 or M153 Quad
86935 GEP250MLTAC4-5
(120/208/240/277V)
86926 GEP25048TAC4-5
1 – 250W PS M138 or M153 480
1 – 320W PS M132 or 154 Quad
86959 GEP320MLTAC4-5
(120/208/240/277V)
86952 GEP32048TAC4-5
1 – 320W PS M132 or M154 480
1 – 320W PS M132 or M154 TRI-Voltage
86968 GEP320TRIAC4-5
120 277 347
1 – 350W PS M131 Quad
86984 GEP350MLTAC4-5
(120/208/240/277V)
86999 GEP40048TAC4-5
1 – 400W PS M135 or M155 480
1 – 400W PS M135 or M155 Quad
87008 GEP400MLTAC4-5
(120/208/240/277V)
46936 GEP75048TAC5-5
1 – 750W PS M149 480
1 – 750W PS M149 Quad
46934 GEP750MLTAC5-5
(120/208/240/277V)
1 – 1000W PS M141 Quad
72281 GEP1000MLTAC5-5
(120/208/240/277V)
1 – 1000W PS M141 5-Tap
72282 GEP1000ML5AC5-5
(120/208/240/277/480V)

High-Pressure Sodium
For 50 – 150W High Pressure Sodium HID Lamps
1 – 50W HPS S68 Quad
87152 GES50MLTLC3D-5
(120/208/240/277V)
1 – 70W HPS S62 Quad
86587 GES70MLTLC3D-5
(120/208/240/277V)
86456 GES7048TLC3D-5
1 – 70W HPS S62 480V
1 – 100W HPS S54 Quad
87074 GES100MLTLC3D-5
(120/208/240/277V)
87068 GES10048TLC3D-5
1 – 100W HPS S54 480V
1 – 150W HPS S55 Quad
87094 GES150MLTLC3D-5
(120/208/240/277V)
87087 GES15048TLC3D-5
1 – 150W HPS S55 480V
For 250 – 1000W High Pressure Sodium HID Lamps
1 – 250W HPS S50 5-Tap
87214 GES250ML5AC4-5
(120/208/240/277/480V)
1 – 250W HPS S50 Quad
87121 GES250MLTAC4-5
(120/208/240/277V)
1 – 400W HPS S51 5-Tap
87215 GES400ML5AC4-5
(120/208/240/277/480V)
1 – 400W HPS S51 Quad
87164 GES400MLTAC4-5
(120/208/240/277V)
1 – 400W HPS S51 480V in smaller
87198 GES40048TAC4-5
frame
87048 GES100048TAC5-5
1 – 1000W HPS S52 480V
1 – 1000W HPS S52 5-Tap
87218 GES1000ML5AC5-5
(120/208/240/277/480V)
1 – 1000W HPS S52 Quad
87056 GES1000MLTAC5-5
(120/208/240/277V)

See page 195 for warranty information.

13

HID Electromagnetic
Ballasts

See page 195 for warranty information.

Units Per
Carton

HID Electronic
Ballasts

144
145

Circuit Type

Compact Fluorescent
Ballasts

12

144

ANSI Lamp Type

Sign
Ballasts

1 – 50W MH M110 or M148 Quad
86824 GEM50MLTLC3D-5
(120/208/240/277V)
1 – 70W MH M98 or M143 Quad
86847 GEM70MLTLC3D-5
(120/208/240/277V)
86839 GEM7048TLC3D-5
1 – 70W MH M98 or M143 480
1 – 100W MH M90 or M140 Quad
86675 GEM100MLTLC3D-5
(120/208/240/277V)
86667 GEM10048TLC3D-5
1 – 100W MH M90 or M140 480
1 – 150W MH M102 or M142 Quad
86718 GEM150MLTLC3D-5
(120/208/240/277V)
86711 GEM15048TLC3D-5
1 – 150W MH M102 or M142 480
1 – 175W MH M57 or H39 5-Tap
87210 GEM175ML5AC3-5
(120/208/240/277/480V)
1 – 175W MH M57 or H39 Quad
86741 GEM175MLTAC3-5
(120/208/240/277V)
For 250 – 1500W Metal Halide HID Lamps
1 – 250W MH M58 or H37 5-Tap
87211 GEM250ML5AC3-5
(120/208/240/277/480V)
1 – 250W MH M58 or H37 Quad
86765 GEM250MLTAC3-5
(120/208/240/277V)
1 – 250W MH M58 or H37 5-Tap
87212 GEM250ML5AC4-5
(120/208/240/277/480V)
1 – 400W MH M59 or H33 5-Tap
72300 GEM400ML5AA4-5
(120/208/240/277/480V) Al C&C
1 – 400W MH M59 or H33 Quad
72149 GEM400MLTAA4-5
(120/208/240/277V) Al C&C
86803 GEM40048TAC4-5
1 – 400W MH M59 or H33 480
86650 GEM100048TAC5-5
1 – 1000W MH M47 or H36 480
1 – 1000W MH M47 or H36 5-Tap
87213 GEM1000ML5AA5-5
(120/208/240/277/480V)
1 – 1000W MH M47 or H36 Quad
86655 GEM1000MLTAA5-5
(120/208/240/277V)
86693 GEM150048TAC5-5
1 – 1500W MH M48 480
1 – 1500W MH M48 Quad
86698 GEM1500MLTAC5-5
(120/208/240/277V)

Product Page
Number

T12
Fluorescent Ballasts

29377

1 – 250 to 400W UltraMax® HID
Electronic 208-277 50-60Hz

135
135

Application

T5
Fluorescent Ballasts

87516

1 – 20W M156 120V Electronic HID
1 – 39W M130 120V Electronic HID
1 – 50W M110 M/C148 120V Electronic
HID
1 – 70W M98 M/C143 120V Electronic
HID
1 – 70W M98 M/C143 120V-277V
Electronic HID
1 – 100W M90 M/C140 120V-277V
Electronic HID
1 – 150W M102 M/C142 120V-277V
Electronic HID

Description

T8
Fluorescent Ballasts

HID Electronic Ballasts

Prod
Code

Quick Reference
Guides

gelighting.com

Quick reference ballast selection guide (cont.)
Prod
Code

Description

Application

Product Page
Number

ANSI Lamp Type

Circuit Type

Units Per
Carton

71701

GEM175ML5AC3-55

GEM250ML5AC3-55

71703

GEM400ML5AC4-55

71704

GEM1000ML5AC4-55

71705

GES100MLTLC3D-55

71706

GES250ML5AC4-55

GES400ML5AC4-55

86578

11210506CTC000C

86574

11210239CTC000I

86563

1110245SCTC000I

86564

1110246CTC000C

42670

1110-247SC-TC

80728

1111-247SCTC000I

1 – 70W M85 120/277 Enclosed
& Potted
1 – 70W M98 120/277 Enclosed
& Potted
1 – 100W M90 120/277 Enclosed
& Potted
1 – 175W M57 120/277 Enclosed
& Potted
1 – 250W M58 120/277 Enclosed
& Potted
1 – 400W M59 120/277 Enclosed
& Potted F-can
1 – 400W M59 120/277 Enclosed
& Potted

Circuit Type

Units Per
Carton

HID ACCESSORIES
Replacement Capacitors

170

M57 Mogul Base
Elliptical Lamp

CWA

1

170

M58 Mogul Base
Elliptical Lamp

CWA

1

171

M59 Mogul Base
Elliptical Lamp

CWA

1

171

M47 Mogul Base
Elliptical Lamp

CWA

1

172

S54 Medium Base
Elliptical Lamp

HX-HPF

1

172

M50 Mogul Base ED18
Lamp

CWA

1

173

S51 Mogul Base ED18
Lamp

CWA

174

M85

174

88980

005-1184-MF

88982

005-1185-MF

89007
89077

005-1422-MF
005-2779-MF

89083

005-3160-MF

20
10.0 MFD 400V 90C 2.4 MEG 1.50 oval
2.7 ht
15.0 MFD 400V 90C 1.6 MEG 1.75 oval
2.7 ht
48.0 MFD 300V 90C 0.6 MEG 1.75 oval
3.9 ht
24.0 MFD 480V 90C 1.75 oval 3.9 ht
24.0 MFD 360V 90C 1.0 MEG 1.75 oval
3.1 ht

179

20

179

20

179
179

20
20

179

20

179

20

179

20

179

10

179
179

100
10

179
179

50
50

Replacement Ignitors for Pulse Start lamps – (MH and HPS)
86864

MH100-3A

86635

HPS150-3A

86641

HPS400-3A

Ignitor for MH 30 50 70 100
Ignitor HPS 150 watts or less except
150W-S56
Ignitor HPS 200-400 watts &
150W S56

Other Accessories

1

47621
86467

000-8724
001-2009

HX-HPF

4

86468
86624

004-9177
2BMB1000C

M98

HX-HPF

4

175

M90

HX-HPF

4

175

M57, H39

CWA

2

176

M58, H37

CWA

2

176

M59, H33

CWA

2

177

M59, H33

CWA

4

178

S62

R-HPF, R-NPF

6

178
179

S62
S55

HX-HPF
R-NPF

4
6

HIDP Adjustable Mounting Bracket
Hardware Kit
Splice Box
Adjustable Mounting Bracket For 4"
HID
HID Parts E&P Mounting Bracket

Sign
Ballasts

11210277CTC000C

ANSI Lamp Type

HID Electromagnetic Ballasts

Enclosed and Potted Metal Halide
86576

Product Page
Number

T12
Fluorescent Ballasts

71707

Application

T5
Fluorescent Ballasts

71702

1 – 175W MH M57 or H39 5-Tap
(120/208/240/277/480V) Lamp
& Ballast Kit (-55)
1 – 250W MH M58 or H37 5-Tap
(120/208/240/277/480V) Lamp
& Ballast Kit (-55)
1 – 400W MH M59 or H33 5-Tap
(120/208/240/277/480V) Lamp
& Ballast Kit (-55)
1 – 1000W MH M47 or H36 5-Tap
(120/208/240/277/480V) Lamp
& Ballast Kit (-55)
1 – 100W HPS S54 Quad
(120/208/240/277V) Lamp & Ballast
Kit (-55)
1 – 250W HPS S50 5-Tap
(120/208/240/277/480V) Lamp &
Ballast Kit (-55)
1 – 400W HPS S51 5-Tap
(120/208/240/277/480V) Lamp &
Ballast Kit (-55)

Description

T8
Fluorescent Ballasts

HID Electromagnetic Ballasts
High Intensity Discharge Lamp Ballast Kits

Prod
Code

F-Can and Post Mount High Pressure Sodium
1233142U000I

86596
86606

12210237CTC000I
1233154U000I

1 – 70W S62 120 Reactor-NPF
1 – 70W S62 120/277 E and P
F-Can built-in starter
1 – 150W S55 120 Reactor-NPF

Compact Fluorescent
Ballasts

86605

HID Electronic
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

15

HID Electromagnetic
Ballasts

14

Quick Reference
Guides

gelighting.com

Quick reference lamp to ballast selection guide

Linear Fluorescent Lamps
F13T5
F14T12

F14T5/HE

120-277
120-277
120
120-277

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start

71430
71427
89712
47536

GEC213-MVPS-3W
GEC213-MVPS-XX
GEM120TC120DIY
B228PUNV-C0G1C

2

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

2
2
2
1

120-277
120-277
120-277
120-277

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

99653
71430
71429
47536

GE228MVPSH-A
GEC213-MVPS-3W
GEC213-MVPS-XX
B228PUNV-C0G1C

1

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

1

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

2

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

2

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

1

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

1
1

120-277 Electronic - Program / Rapid Start
120
Magnetic - Rapid Start

99653
89711

GE228MVPSH-A
GEM120PH120DIY

80819
89711
89712

GEM220TS120DIY
GEM120PH120DIY
GEM120TC120DIY

F15T8

2
1
1

120
120
120

Magnetic - Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start

80819
89711
89712

GEM220TS120DIY
GEM120PH120DIY
GEM120TC120DIY

4

120-277

3

120-277

3
3

120-277

2

120-277

2

120-277

2

F17T8

16

120-277

120-277

1

120-277

4

120-277

4

120-277

4
4
4
4
4
4
4
4
4
4
4
4

120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
120
120
120

3

120-277

3

120-277

3

120-277

77
77
123
123
78
77
77
77
77
77
77
90
92
90
90
92
90
90

3
3
3
3
3
3
3

120-277
120-277
120-277
120-277
120-277
120-277
120-277

3

120-277

3

120-277

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
277
120
120
120
120
120

2

120-277

2

120-277

71423

GE432MAX-N+

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax

44

71421

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

2
2
2
2
2
2
2
2
2
2

71422

GE332MAX-N+

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

42

2

GE332MAX-N+

®

42

2

120-277

71421

GE232MAX-N+

®

40

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

44

71725

GE432MAX-L/ULTRA

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
277
277
120
120
120
120
120
120

1

120-277

1
1

120-277
120-277

1

120-277

71423

GE432MAX-N+

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

44

71422

GE332MAX-N+

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

42

GE332MAX-N+

®

42

®

71422

71422

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax
2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax®
®

71727
30219
30262
30193
30193
29678
96716
23676
29627
23675
29625
97783

GE432MAX-N/ULTRA
GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-MVPS-H
GE432-MVPS-N
GE-432-277-N
GE-432-277-PS-N
GE-432-120-N
GE-432-120-PS-N
GE432-120-RES

4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax
4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 120V “N”.87 BF ProLine®
4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B

71714

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®
®

43
44
49
50
50
50
68
67
56
66
62
66
58
41

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax

41

71719

GE332MAX-N/ULTRA 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax®

42

See page 195 for warranty information.

F17T8
(cont)

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start

See page 195 for warranty information.

3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

48
48
49
64
65
64
65

30199
30255
30192
29676
96721
96715
29672

GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-MVPS-H
GE332-MVPS-L
GE332-MVPS-N
GE-332-MVPS-XL

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

71725

GE432MAX-L/ULTRA

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax®

43

71727
30219
30262
30193
30193
29678
96716
23674
29624
23676
29627
23673
29623
23675
29625
97783

GE432MAX-N/ULTRA
GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-MVPS-H
GE432-MVPS-N
GE-332-277-N
GE-332-277-PS-N
GE-432-277-N
GE-432-277-PS-N
GE-332-120-N
GE-332-120-PS-N
GE-432-120-N
GE-432-120-PS-N
GE432-120-RES

4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax®
4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 120V “N”.87 BF ProLine®
4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B

44
49
50
50
50
68
67
55
63
56
66
55
63
56
66
58

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

72262

®

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax

®

72266
30198
30198
72273
72275
72275
29675
96720
96714
29671

GE232MAX-N/ULTRA
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N
GE-232-MV-N
GE-232-MVPS-H
GE232-MVPS-L
GE232-MVPS-N
GE-232-MVPS-XL

2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

71714

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®
®

43

39
39
40
46
46
47
47
47
62
61
61
62
41

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax

71719
30199
30255
30192
29676
96721
96715
29672
23672
29622
23674
29624
87130
23671
29621
97782
23673
23673
29623

GE332MAX-N/ULTRA
GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-MVPS-H
GE332-MVPS-L
GE332-MVPS-N
GE-332-MVPS-XL
GE-232-277-N
GE-232-277-PS-N
GE-332-277-N
GE-332-277-PS-N
GEM232T8RS277
GE-232-120-N
GE-232-120-PS-N
GE232-120-RES
GE-332-120-N
GE-332-120-N
GE-332-120-PS-N

72258

GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax®

38

72259
72269

GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax®
GE-132-MV-N
1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®

38
46

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax®
3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD
2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
2 - F32T8 RS 277V Magnetic Ballast (M232SR277C)
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF Residential ProLine®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®

41
42
48
48
49
64
65
64
65
54
60
55
63
59
54
60
58
55
55
63

17

HID Electromagnetic
Ballasts

Magnetic - Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start

Linear Fluorescent Lamps

HID Electronic
Ballasts

120
120
120

123
44
90
78

Prod Code
Page No

Fluorescent Ballast Long Description

Compact Fluorescent
Ballasts

2
1
1

2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
1 - F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (546BTCP)
2 - F28T5 PRS UNV 50/60 Hz
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
2 - F28T5 PRS UNV 50/60 Hz
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
1 - F20T12 F15T8 F1512 120V Magnetic Ballast (200H2)
2- F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast
(447LRVLHTCP)
1 - F20T12 F15T8 F1512 120V Magnetic Ballast (200H2)
1 - F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (546BTCP)
2- F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast
(447LRVLHTCP)
1 - F20T12 F15T8 F1512 120V Magnetic Ballast (200H2)
1 - F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (546BTCP)

Ballast
Product
Code Ballast Description

Sign
Ballasts

F15T12

Fluorescent Ballast Long Description

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

T12
Fluorescent Ballasts

F14T8

2
2
1
2

Prod Code
Page No

T5
Fluorescent Ballasts

F14T5/WM

Ballast
Product
Code Ballast Description

T8
Fluorescent Ballasts

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

Quick Reference
Guides

gelighting.com

Quick reference lamp to ballast selection guide (cont.)
Ballast
Product
Code Ballast Description

Prod Code
Page No

Fluorescent Ballast Long Description

Linear Fluorescent Lamps

F18T8

F21T5/HE

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax

71723
30198
30198
72273
72275
72275
29675
96720

GE232MAX-N/ULTRA
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N
GE-232-MV-N
GE-232-MVPS-H
GE232-MVPS-L

39

4

43
46
46
47
47
47
62
61

4
4
4

99655

GE228MVPS-A

1
2
2

120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start

99653
47534
47540

GE228MVPSH-A
B224PUNV-COG1C
B239PUNV-DOG1C

2

120-277 Electronic - Program / Rapid Start

71445

GEC226-MVPS-3W

2
1
1

120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start

71444
47534
47540

GEC226-MVPS-XX
B224PUNV-COG1C
B239PUNV-DOG1C

71423

GE432MAX-N+

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

44

GE332MAX-N+

®

42

®

44

120-277
120-277
277
277
277
120
120
120
120
120
120-277

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start

96714
29671
23681
23672
29622
23680
23671
29621
97782
89711
24107

GE232-MVPS-N
GE-232-MVPS-XL
GE-132-277-N
GE-232-277-N
GE-232-277-PS-N
GE-132-120-N
GE-232-120-N
GE-232-120-PS-N
GE232-120-RES
GEM120PH120DIY
GE-240-RS-MV-N

2
1
1
1
2

120
120-277
120
120
120-277

Magnetic - Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start

80819
24107
89711
89712
47536

GEM220TS120DIY
GE-240-RS-MV-N
GEM120PH120DIY
GEM120TC120DIY
B228PUNV-C0G1C

2

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

2

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

2
1

120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start

99653
47536

GE228MVPSH-A
B228PUNV-C0G1C

1

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

1

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

1

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

2

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

2

3
3
2
2
1
4

120-277 Electronic - Program / Rapid Start

99653

71422
71423

GE228MVPSH-A

GE432MAX-N+

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax

92
85
90
90
78

3
3
3
3
3
3
3
2
F25T12
(cont)

2
2

77

2

77

2

77

2
2
2
2
2
2

77

1

77

1

77
78
77

1

77
77

1

77
79
79

1
1
1
1
1

124

4
4

124
79
79

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

71422

GE332MAX-N+

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

42

71421

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

3

61
62
53
54
60
53
54
60
58
90
85

71421

71723

3

43

3
3
3
F25T8

2
2
1
4
4
4

18

See page 195 for warranty information.

See page 195 for warranty information.

71725

GE432MAX-L/ULTRA

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax®

43

71727
23676
23675

GE432MAX-N/ULTRA 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax®
GE-432-277-N
4 or 3 - F32T8 277V “N”.87 BF ProLine®
GE-432-120-N
4 or 3 - F32T8 120V “N”.87 BF ProLine®

44
56
56

71714

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

41

71717

®

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax

41

®

71719

GE332MAX-N/ULTRA 3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax

42

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

43

71725

GE432MAX-L/ULTRA

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax®

43

®

4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax
3 or 2 - F32T8 277V “N”.87 BF ProLine®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
4 or 3 - F32T8 120V “N”.87 BF ProLine®

44
55
56
55
56

71727
23674
23676
23673
23675

GE432MAX-N/ULTRA
GE-332-277-N
GE-432-277-N
GE-332-120-N
GE-432-120-N

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

71725

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax®

43

®

72266

GE232MAX-N/ULTRA 2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax

40

71714

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

41

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax®

41

®

71719
23672
23674
23671
97498
23673

GE332MAX-N/ULTRA
GE-232-277-N
GE-332-277-N
GE-232-120-N
GE240RS120
GE-332-120-N

72258

GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax®

72259

GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax®

49775

3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax
2 or 1 - F32T8 277V “N”.87 BF ProLine®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 F40 or F34T12 Rapid Start Electronic 120V “N” BF
3 or 2 - F32T8 120V “N”.87 BF ProLine®

42
54
55
54
85
55
38
38

®

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax
®

39
43

71725

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax

72266
23681
23672
23680
23671

GE232MAX-N/ULTRA
GE-132-277-N
GE-232-277-N
GE-132-120-N
GE-232-120-N

2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax®
1 - F32T8 277V “N”.87 BF ProLine®
2 or 1 - F32T8 277V “N”.87 BF ProLine®
1 - F32T8 120V “N”.87 BF ProLine®
2 or 1 - F32T8 120V “N”.87 BF ProLine®

40
53
54
53
54

71423
71832

GE432MAX-N+
GE432-MVPS-L

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®
4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

44
67

71422

GE332MAX-N+

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

42

71423
71832

GE432MAX-N+
GE432-MVPS-L

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®
4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

44
67

71421

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

71422

GE332MAX-N+

®

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax

42

71421

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

43

71725
71727

GE432MAX-L/ULTRA

®

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax

®

GE432MAX-N/ULTRA 4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax

43
44
19

HID Electromagnetic
Ballasts

120-277 Electronic - Program / Rapid Start

1
1
1
1
1
1
1
1
1
1
2

3

Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
277
Electronic - Standard Instant Start
120
Electronic - Standard Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
277
Electronic - Standard Instant Start
277
Electronic - Standard Instant Start
120
Electronic - Standard Instant Start
120
Electronic - Standard Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
277
Electronic - Standard Instant Start
277
Electronic - Standard Instant Start
120
Electronic - Standard Instant Start
120
Electronic - Program / Rapid Start
120
Electronic - Standard Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
277
Electronic - Standard Instant Start
277
Electronic - Standard Instant Start
120
Electronic - Standard Instant Start
120
Electronic - Standard Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
120-277 Electronic - Program / Rapid Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
120-277 Electronic - Program / Rapid Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start

HID Electronic
Ballasts

1

2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD
UltraStart®
2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD
1 - F32T8 277V “N”.87 BF ProLine®
2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
1 - F32T8 120V “N”.87 BF ProLine®
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF Residential ProLine®
1 - F20T12 F15T8 F1512 120V Magnetic Ballast (200H2)
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
2- F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast
(447LRVLHTCP)
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
1 - F20T12 F15T8 F1512 120V Magnetic Ballast (200H2)
1 - F20T12 F15T8 F15T12 F14T12 120V Magnetic Ballast (546BTCP)
2 - F28T5 PRS UNV 50/60 Hz
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
15 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 - F28T5 PRS UNV 50/60 Hz
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
14 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 - F24T5HO PRS UNV 50/60 Hz
2 - F39T5HO PRS UNV 50/60 Hz
2 - CFQ26W, FT24 or 1-42W, CFTR32 3-Way Mounting Kit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V
ProLine® PS
2 - F24T5HO PRS UNV 50/60 Hz
2 - F39T5HO PRS UNV 50/60 Hz

4

F25T12

72262

Compact Fluorescent
Ballasts

F24T5/HO

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

Linear Fluorescent Lamps
®

Sign
Ballasts

F21T5/WM

1
1
1
1
1
1
1
1

Prod Code
Page No

Fluorescent Ballast Long Description

T12
Fluorescent Ballasts

F20T12

120-277

Ballast
Product
Code Ballast Description

T5
Fluorescent Ballasts

F17T8
(cont)

1

Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

T8
Fluorescent Ballasts

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

Quick Reference
Guides

gelighting.com

Quick reference lamp to ballast selection guide (cont.)

Linear Fluorescent Lamps

3

120-277

3

120-277

3
3
3
3
3
3
3
3

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

3

120-277

3

120-277

2

120-277

2
2
2
2
2
2
2
2

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

2
2

120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
120-277 Electronic - Multivolt Instant Start
120-277 Electronic - Multivolt Instant Start
120-277 Electronic - Multivolt Instant Start
120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start
277
Electronic - Dimming
277
Electronic - Dimming

2
2
2
2
2
2
2
2
2
2
2

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

41

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax®

41

71719
30199
30255
30192
29676
96721
96715
29672

GE332MAX-N/ULTRA
GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-MVPS-H
GE332-MVPS-L
GE332-MVPS-N
GE-332-MVPS-XL

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

71725

GE432MAX-L/ULTRA

3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax®
3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax®
®

4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax
4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 120V “N”.87 BF ProLine®
4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B

42
48
48
49
64
65
64
65
43
43

71727
30219
30262
30193
30193
29678
96716
23674
29624
23676
29627
23673
29623
23675
29625
97783

GE432MAX-N/ULTRA
GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-MVPS-H
GE432-MVPS-N
GE-332-277-N
GE-332-277-PS-N
GE-432-277-N
GE-432-277-PS-N
GE-332-120-N
GE-332-120-PS-N
GE-432-120-N
GE-432-120-PS-N
GE432-120-RES

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

72262

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax®

39

72266
30198
30198
72273
72275
72275
29675
96720

GE232MAX-N/ULTRA
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N
GE-232-MV-N
GE-232-MVPS-H
GE232-MVPS-L

96714
29671

GE232-MVPS-N
GE-232-MVPS-XL

71714

2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

F25T8
(cont)

44
49
50
50
50
68
67
55
63
56
66
55
63
56
66
58

40
46
46
47
47
47
62
61

F28T5

F28T5/HE

2
2
2
2
2
2
2
2
2
2

277
277
277
277
277
120
120
120
120
120

1

120-277

1
1
1
1
1
1
1
1

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

1

120-277

1
1

120-277
120-277

1

120-277

1
1
1
1
1
1
1
1
1
1
1
2

120-277
120-277
277
277
277
120
120
120
120
120
120
120-277

72258

GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax®

38

72259
72269

GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax®
GE-132-MV-N
1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®

38
46

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

®

72262

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax

72266
30198
30198
72273
72275
72275
29675
96720

GE232MAX-N/ULTRA
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N
GE-232-MV-N
GE-232-MVPS-H
GE232-MVPS-L

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Dimming
Electronic - Dimming
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start

96714
29671
23681
23672
29622
80353
80353
23680
23671
29621
97782
47536

GE232-MVPS-N
GE-232-MVPS-XL
GE-132-277-N
GE-232-277-N
GE-232-277-PS-N
B132R120V5
B132R120V5
GE-132-120-N
GE-232-120-N
GE-232-120-PS-N
GE232-120-RES
B228PUNV-C0G1C

2
1

120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start

99653
47536

GE228MVPSH-A
B228PUNV-C0G1C

1

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

2

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

2

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

1

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

1

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

2

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

2

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

1

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

41

1

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax®

41

2

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

71719
30199
30255
30192
29676
96721
96715
29672
80362
80362

GE332MAX-N/ULTRA
GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-MVPS-H
GE332-MVPS-L
GE332-MVPS-N
GE-332-MVPS-XL
B232SR277S50
B232SR277S50

2

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

1

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

1

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax®
3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD
2 - F32T8 Switch 100/50% RS 277
2 - F32T8 Switch 100/50% RS 277

42
48
48
49
64
65
64
65
70
70

See page 195 for warranty information.

F28T5/WM

See page 195 for warranty information.

54
60
55
63
59
54
60
58
55
63

GE-232-277-N
GE-232-277-PS-N
GE-332-277-N
GE-332-277-PS-N
GEM232T8RS277
GE-232-120-N
GE-232-120-PS-N
GE232-120-RES
GE-332-120-N
GE-332-120-PS-N

61
62

F28T5/HL

2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
2 - F32T8 RS 277V Magnetic Ballast (M232SR277C)
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF Residential ProLine®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®

23672
29622
23674
29624
87130
23671
29621
97782
23673
29623

2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD
UltraStart®
2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD
1 - F32T8 277V “N”.87 BF ProLine®
2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
1 - F32T8 DIM 100 to 5% RS 120
1 - F32T8 DIM 100 to 5% RS 120
1 - F32T8 120V “N”.87 BF ProLine®
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF Residential ProLine®
2 - F28T5 PRS UNV 50/60 Hz
8 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 - F28T5 PRS UNV 50/60 Hz
7 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15 BF
A Can

39
40
46
46
47
47
47
62
61
61
62
53
54
60
69
69
53
54
60
58
78
77
78
77
77
77
77
77
77
77
77
77
77
77
77
77

21

HID Electromagnetic
Ballasts

120-277

71714

Linear Fluorescent Lamps

HID Electronic
Ballasts

2

49
50
50
50
68
67
56
66
56
66
58

GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-MVPS-H
GE432-MVPS-N
GE-432-277-N
GE-432-277-PS-N
GE-432-120-N
GE-432-120-PS-N
GE432-120-RES

Prod Code
Page No

Fluorescent Ballast Long Description

Compact Fluorescent
Ballasts

120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
277
120
120
120
120
120

4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 120V “N”.87 BF ProLine®
4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B

30219
30262
30193
30193
29678
96716
23676
29627
23675
29625
97783

Ballast
Product
Code Ballast Description

Sign
Ballasts

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

2

20

Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

Fluorescent Ballast Long Description

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

T12
Fluorescent Ballasts

120-277
120-277
120-277
120-277
120-277
120-277
277
277
120
120
120

Prod Code
Page No

T5
Fluorescent Ballasts

F25T8
(cont)

4
4
4
4
4
4
4
4
4
4
4

Ballast
Product
Code Ballast Description

T8
Fluorescent Ballasts

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

Quick Reference
Guides

gelighting.com

Quick reference lamp to ballast selection guide (cont.)
Ballast
Product
Code Ballast Description

Prod Code
Page No

Fluorescent Ballast Long Description

Linear Fluorescent Lamps
120-277
120-277

3

120-277

3
3

120-277
120-277

2

120-277

2

120-277

1

120-277

4

120-277

120-277

3

120-277

3
3
3
3
3
3
3
3

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

3

120-277

3

120-277

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
277
120
120
120
120
120

2

120-277

2

120-277

2
2
2
2
2
22

120-277
120-277
120-277
120-277
120-277

71422

GE332MAX-N+

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

42

71423
71832

GE432MAX-N+
GE432-MVPS-L

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®
4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

44
67

71421

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

71422

GE332MAX-N+

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

42

71421

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

43

®

71725

GE432MAX-L/ULTRA

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax

43

71727
30219
30262
30193
30193
29678
96716
23676
29627
23675
29625
97783

GE432MAX-N/ULTRA
GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-MVPS-H
GE432-MVPS-N
GE-432-277-N
GE-432-277-PS-N
GE-432-120-N
GE-432-120-PS-N
GE432-120-RES

4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax®
4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 120V “N”.87 BF ProLine®
4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B

44
49
50
50
50
68
67
56
66
56
66
58

71714

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

41

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax®

41

71719
30199
30255
30192
29676
96721
96715
29672

GE332MAX-N/ULTRA
GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-MVPS-H
GE332-MVPS-L
GE332-MVPS-N
GE-332-MVPS-XL

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

71725

GE432MAX-L/ULTRA

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax®

43

71727
30219
30262
30193
30193
29678
96716
23674
29624
23676
29627
23673
29623
23675
29625
97783

GE432MAX-N/ULTRA
GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-MVPS-H
GE432-MVPS-N
GE-332-277-N
GE-332-277-PS-N
GE-432-277-N
GE-432-277-PS-N
GE-332-120-N
GE-332-120-PS-N
GE-432-120-N
GE-432-120-PS-N
GE432-120-RES

4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax®
4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 120V “N”.87 BF ProLine®
4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B

44
49
50
50
50
68
67
55
63
56
66
55
63
56
66
58

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

72262

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax®

39

72266
30198
30198
72273
72275

GE232MAX-N/ULTRA
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N

3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax®
3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

®

2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®

F28T8
(cont)

42
48
48
49
64
65
64
65
43

40
46
46
47
47

See page 195 for warranty information.

F30T12

F30T12/WM

F32T8

2
2
2
2
2

120-277
120-277
120-277
120-277
120-277

2

120-277

2

120-277

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
277
120
120
120
120
120

1

120-277

1
1

120-277
120-277

1

120-277

1

120-277

1
1
1
1
1
1
1
1

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

1
1
1
1
1
1
1
1
1
3
2
2
2
2
1
1
1
1
2
3
2
2
1

120-277
120-277
277
277
277
120
120
120
120
120-277
120-277
120-277
120
120
120-277
120
120
120
120
120-277
120-277
120-277
120-277

4
4
3

Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
120-277 Multivolt Instant Start
120-277 Electronic - Program / Rapid Start
Electronic - High Efficiency
120-277 Multivolt Instant Start

See page 195 for warranty information.

2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

47
62
61
61
62

72275
29675
96720
96714
29671

GE-232-MV-N
GE-232-MVPS-H
GE232-MVPS-L
GE232-MVPS-N
GE-232-MVPS-XL

71714

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

41

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax®

41

71719
30199
30255
30192
29676
96721
96715
29672
23672
29622
23674
29624
23671
29621
97782
23673
29623

GE332MAX-N/ULTRA
GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-MVPS-H
GE332-MVPS-L
GE332-MVPS-N
GE-332-MVPS-XL
GE-232-277-N
GE-232-277-PS-N
GE-332-277-N
GE-332-277-PS-N
GE-232-120-N
GE-232-120-PS-N
GE232-120-RES
GE-332-120-N
GE-332-120-PS-N

72258

GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax®

38

72259
72269

GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax®
GE-132-MV-N
1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®

38
46

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

72262

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax®

39

72266
30198
30198
72273
72275
72275
29675
96720

GE232MAX-N/ULTRA
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N
GE-232-MV-N
GE-232-MVPS-H
GE232-MVPS-L

96714
29671
23681
23672
29622
23680
23671
29621
97782
24109
24107
24109
97498
80644
24107
72110
72110
89709
80644
24109
24107
24109
24107

3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax®
3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD
2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF Residential ProLine®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®

42
48
48
49
64
65
64
65
54
60
55
63
54
60
58
55
63

40
46
46
47
47
47
62
61

GE232-MVPS-N
GE-232-MVPS-XL
GE-132-277-N
GE-232-277-N
GE-232-277-PS-N
GE-132-120-N
GE-232-120-N
GE-232-120-PS-N
GE232-120-RES
GE-340-RS-MV-N
GE-240-RS-MV-N
GE-340-RS-MV-N
GE240RS120
GEM230RS120DIY
GE-240-RS-MV-N
GE140RS120-DIY
GE140RS120-DIY
GEM140RS120DIY
GEM230RS120DIY
GE-340-RS-MV-N
GE-240-RS-MV-N
GE-340-RS-MV-N
GE-240-RS-MV-N

2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD
UltraStart®
2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD
1 - F32T8 277V “N”.87 BF ProLine®
2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
1 - F32T8 120V “N”.87 BF ProLine®
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF Residential ProLine®
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 F40 or F34T12 Rapid Start Electronic 120V “N” BF
2 - F30T12 120V Magnetic Ballast (573LTCP)
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack
1 F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack
1 - F40T12 F30T12 F48/25W 120V Magnetic Ballast (413CTCP)
2 - F30T12 120V Magnetic Ballast (573LTCP)
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12

71423
71832

GE432MAX-N+
GE432-MVPS-L

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®
4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

44
67

71422

GE332MAX-N+

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

42

61
62
53
54
60
53
54
60
58
86
85
86
85
94
85
86
86
93
94
86
85
86
85

23

HID Electromagnetic
Ballasts

3

44
67

HID Electronic
Ballasts

120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
120
120
120

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax
4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

Compact Fluorescent
Ballasts

4
4
4
4
4
4
4
4
4
4
4
4

GE432MAX-N+
GE432-MVPS-L

Prod Code
Page No

Sign
Ballasts

120-277

71423
71832

Fluorescent Ballast Long Description

T12
Fluorescent Ballasts

4

Linear Fluorescent Lamps
®

Ballast
Product
Code Ballast Description

T5
Fluorescent Ballasts

F28T8

4
4

Electronic - High Efficiency
Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

T8
Fluorescent Ballasts

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

Quick Reference
Guides

gelighting.com

Quick reference lamp to ballast selection guide (cont.)
Ballast
Product
Code Ballast Description

Prod Code
Page No

Fluorescent Ballast Long Description

Linear Fluorescent Lamps
120-277
120-277

2

120-277
120-277

1

120-277

4

120-277

4

120-277

4
4
4
4
4
4
4
4
4
4
4
4

120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
120
120
120

3

120-277

3

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

3

120-277

3

2

120-277

2

120-277

71421

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

71422

GE332MAX-N+

®

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax

42

71421

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

43

71725

GE432MAX-L/ULTRA

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax®

43

71727
30219
30262
30193
30193
29678
96716
23676
29627
23675
29625
97783

GE432MAX-N/ULTRA
GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-MVPS-H
GE432-MVPS-N
GE-432-277-N
GE-432-277-PS-N
GE-432-120-N
GE-432-120-PS-N
GE432-120-RES

4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax®
4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 120V “N”.87 BF ProLine®
4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B

44
49
50
50
50
68
67
56
66
56
66
58

71714

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

41

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax®

41

®

71719
30199
30255
30192
29676
96721
96715
29672

GE332MAX-N/ULTRA
GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-MVPS-H
GE332-MVPS-L
GE332-MVPS-N
GE-332-MVPS-XL

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

71725

GE432MAX-L/ULTRA

71727
30219
30262
30193
30193
29678
96716
80358
80358
23674
29624
23676
29627
80357
80357
23673
29623
23675
29625
97783

GE432MAX-N/ULTRA
GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-MVPS-H
GE432-MVPS-N
B332SR277V5
B332SR277V5
GE-332-277-N
GE-332-277-PS-N
GE-432-277-N
GE-432-277-PS-N
B332SR120V5
B332SR120V5
GE-332-120-N
GE-332-120-PS-N
GE-432-120-N
GE-432-120-PS-N
GE432-120-RES

49775
72262

3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax
3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

®

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax

®

4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax
4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 DIM 100 to 5% RS 277
3 - F32T8 DIM 100 to 5% RS 277
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
3 - F32T8 DIM 100 to 5% RS 120
3 - F32T8 DIM 100 to 5% RS 120
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 120V “N”.87 BF ProLine®
4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B

42
48
48
49
64
65
64
65

F32T8
(cont)

120-277
120-277
120-277
120-277

2

120-277

2

120-277

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
277
277
277
277
277
277
277
120
120
120
120
120
120
120
120

1

120-277

1
1

120-277
120-277

43

1

120-277

43

1

120-277

44
49
50
50
50
68
67
71
71
55
63
56
66
71
71
55
63
56
66
58

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
120
120
120
120
120
120

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

4
4

120-277
120-277

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax®

39

3

120-277

3
3

120-277
120-277

2

120-277

F32T8/WM
72266
30198
30198
72273
72275
72275

2
2
2
2

GE232MAX-N/ULTRA
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N
GE-232-MV-N

2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®

40
46
46
47
47
47

See page 195 for warranty information.

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Dimming
Electronic - Dimming
Electronic - Dimming
Electronic - Dimming
Electronic - Dimming
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Dimming
Electronic - Dimming
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Dimming
Electronic - Dimming
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start

See page 195 for warranty information.

2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

62
61
61
62

29675
96720
96714
29671

GE-232-MVPS-H
GE232-MVPS-L
GE232-MVPS-N
GE-232-MVPS-XL

71714

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

41

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax®

41

71719
30199
30255
30192
29676
96721
96715
29672
80362
80362
80362
80356
80356
23672
29622
23674
29624
87130
80355
80355
23671
29621
97782
23673
29623
87125

GE332MAX-N/ULTRA
GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-MVPS-H
GE332-MVPS-L
GE332-MVPS-N
GE-332-MVPS-XL
B232SR277S50
B232SR277S50
B232SR277S50
B232SR277V5
B232SR277V5
GE-232-277-N
GE-232-277-PS-N
GE-332-277-N
GE-332-277-PS-N
GEM232T8RS277
B232SR120V5
B232SR120V5
GE-232-120-N
GE-232-120-PS-N
GE232-120-RES
GE-332-120-N
GE-332-120-PS-N
GEM232T8RS120

72258

GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax®

3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax®
3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD
2 - F32T8 Switch 100/50% RS 277
2 - F32T8 Switch 100/50% RS 277
2 - F32T8 Switch 100/50% RS 277
2 - F32T8 DIM 100 to 5% RS 277
2 - F32T8 DIM 100 to 5% RS 277
2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
2 - F32T8 RS 277V Magnetic Ballast (M232SR277C)
2 - F32T8 DIM 100 to 5% RS 120
2 - F32T8 DIM 100 to 5% RS 120
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF Residential ProLine®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 - F32T8 RS 120V Magnetic Ballast (M232SR120C)

42
48
48
49
64
65
64
65
70
70
70
70
70
54
60
55
63
59
69
69
54
60
58
55
63
59
38

®

72259
72269

GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax
GE-132-MV-N
1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®

38
46

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

72262

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax®

39

®

72266
30198
30198
72273
72275
72275
29675
96720
96714
29671
23681
23672
29622
80353
80353
23680
23671
29621
97782

GE232MAX-N/ULTRA
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N
GE-232-MV-N
GE-232-MVPS-H
GE232-MVPS-L
GE232-MVPS-N
GE-232-MVPS-XL
GE-132-277-N
GE-232-277-N
GE-232-277-PS-N
B132R120V5
B132R120V5
GE-132-120-N
GE-232-120-N
GE-232-120-PS-N
GE232-120-RES

2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD
1 - F32T8 277V “N”.87 BF ProLine®
2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
1 - F32T8 DIM 100 to 5% RS 120
1 - F32T8 DIM 100 to 5% RS 120
1 - F32T8 120V “N”.87 BF ProLine®
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF Residential ProLine®

40
46
46
47
47
47
62
61
61
62
53
54
60
69
69
53
54
60
58

71423
71832

GE432MAX-N+
GE432-MVPS-L

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®
4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

44
67

71422

GE332MAX-N+

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

42

71423
71832

GE432MAX-N+
GE432-MVPS-L

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®
4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

44
67

71421

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

25

HID Electromagnetic
Ballasts

120-277
120-277
120-277
120-277
120-277
120-277

44
67

HID Electronic
Ballasts

120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
277
277
277
120
120
120
120
120
120
120

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax
4 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

Compact Fluorescent
Ballasts

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

2
2
2
2
2
2
24

120-277

GE432MAX-N+
GE432-MVPS-L

Sign
Ballasts

3
3
3
3
3
3
3
3

71423
71832

Prod Code
Page No

Fluorescent Ballast Long Description

T12
Fluorescent Ballasts

2

Linear Fluorescent Lamps
®

Ballast
Product
Code Ballast Description

T5
Fluorescent Ballasts

F32T8
(cont)

3
3

Electronic - High Efficiency
Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Dimming
Electronic - Dimming
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Dimming
Electronic - Dimming
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

T8
Fluorescent Ballasts

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

Quick Reference
Guides

gelighting.com

Quick reference lamp to ballast selection guide (cont.)
Ballast
Product
Code Ballast Description

Prod Code
Page No

Fluorescent Ballast Long Description

Linear Fluorescent Lamps
2

120-277

1

120-277

4

120-277

4

120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
120
120
120

3

120-277

3

120-277

3
3
3
3
3
3
3
3

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

3

120-277

120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
277
120
120
120
120
120

2

120-277

2

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

2

120-277

2

120-277

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax

42

71421

GE232MAX-N+

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

40

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

43

71725

GE432MAX-L/ULTRA

®

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax

®

4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax
4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 120V “N”.87 BF ProLine®
4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B

43

71727
30219
30262
30193
30193
29678
96716
23676
29627
23675
29625
97783

GE432MAX-N/ULTRA
GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-MVPS-H
GE432-MVPS-N
GE-432-277-N
GE-432-277-PS-N
GE-432-120-N
GE-432-120-PS-N
GE432-120-RES

71714

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

41

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax®

71719
30199
30255
30192
29676
96721
96715
29672

GE332MAX-N/ULTRA
GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-MVPS-H
GE332-MVPS-L
GE332-MVPS-N
GE-332-MVPS-XL

71723

GE432MAX-H/ULTRA 4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax®
3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

®

44
49
50
50
50
68
67
56
66
56
66
58

72266
30198
30198
72273
72275
72275
29675
96720
96714
29671
23681
23672
29622
23680
23671
29621
97782
24109
24107
24109
97498
97498
24107
72110
72110
89714
89709
47536

GE232MAX-N/ULTRA
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N
GE-232-MV-N
GE-232-MVPS-H
GE232-MVPS-L
GE232-MVPS-N
GE-232-MVPS-XL
GE-132-277-N
GE-232-277-N
GE-232-277-PS-N
GE-132-120-N
GE-232-120-N
GE-232-120-PS-N
GE232-120-RES
GE-340-RS-MV-N
GE-240-RS-MV-N
GE-340-RS-MV-N
GE240RS120
GE240RS120
GE-240-RS-MV-N
GE140RS120-DIY
GE140RS120-DIY
GEM140HRS120DIY
GEM140RS120DIY
B228PUNV-C0G1C

2

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

2
1

120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start

99653
47536

GE228MVPSH-A
B228PUNV-C0G1C

1

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

1

120-277 Electronic - Program / Rapid Start

99653

GE228MVPSH-A

2

120-277 Electronic - Program / Rapid Start

99655

GE228MVPS-A

1
2
1
1

120-277
120-277
120-277
120-277

99655
47540
47534
47540

GE228MVPS-A
B239PUNV-DOG1C
B224PUNV-COG1C
B239PUNV-DOG1C

1

120-277
120-277
120-277

41

1

120-277

42
48
48
49
64
65
64
65

1

120-277

F32T8/WM
(cont)

43

GE432MAX-L/ULTRA

4 or 3 - F32T8 120 to 277 “L” .77 BF UltraMax

43

71727
30219
30262
30193
30193
29678
96716
23674
29624
23676
29627
23673
29623
23675
29625
97783

GE432MAX-N/ULTRA
GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-MVPS-H
GE432-MVPS-N
GE-332-277-N
GE-332-277-PS-N
GE-432-277-N
GE-432-277-PS-N
GE-332-120-N
GE-332-120-PS-N
GE-432-120-N
GE-432-120-PS-N
GE432-120-RES

4 or 3 - F32T8 120 to 277 “N” .87 BF UltraMax®
4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
4 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 - F32T8 120V “N”.87 BF ProLine®
4 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
4 or 3 F32T8 120V Normal Light Residential Grade FCC Class B

44
49
50
50
50
68
67
55
63
56
66
55
63
56
66
58

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

72262

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax®

39

F34T12

F35T5/HE
2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
120
120
120
120
120-277
120-277
120-277
120
120
120-277
120
120
120
120
120-277

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
277
277
277
120
120
120
120
120

1
1

71725

®

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
2
2
2
2
1
1
1
1
1
2

Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

72266
30198
30198
72273
72275
72275
29675
96720
96714
29671

GE232MAX-N/ULTRA
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N
GE-232-MV-N
GE-232-MVPS-H
GE232-MVPS-L
GE232-MVPS-N
GE-232-MVPS-XL

71714

GE332MAX-H/ULTRA 3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

41

71717

GE332MAX-L/ULTRA 3 or 2 - F32T8 120 to 277 “L” .77 BF UltraMax®

41

40
46
46
47
47
47
62
61
61
62

See page 195 for warranty information.

F35T5/WM

F39T5/HO

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

See page 195 for warranty information.

3 or 2 - F32T8 120 to 277 “N” .87 BF UltraMax®
3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
3 - F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
3 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
3 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD
2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF Residential ProLine®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
3 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®

71719
30199
30255
30192
29676
96721
96715
29672
23672
29622
23674
29624
23671
29621
97782
23673
29623

GE332MAX-N/ULTRA
GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-MVPS-H
GE332-MVPS-L
GE332-MVPS-N
GE-332-MVPS-XL
GE-232-277-N
GE-232-277-PS-N
GE-332-277-N
GE-332-277-PS-N
GE-232-120-N
GE-232-120-PS-N
GE232-120-RES
GE-332-120-N
GE-332-120-PS-N

72258

GE132MAX-L/ULTRA 1 - F32T8 120 to 277 “L” .77BF UltraMax®

42
48
48
49
64
65
64
65
54
60
55
63
54
60
58
55
63
38

®

72259
72269

GE132MAX-N/ULTRA 1 - F32T8 120 to 277”N” .87 BF UltraMax
GE-132-MV-N
1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®

38
46

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

72262

GE232MAX-L/ULTRA 2 or 1 - F32T8 120 to 277 “L” .77 BF UltraMax®

39

®

2 or 1 - F32T8 120 to 277 “N” .87 BF UltraMax
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 - F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®
2 or 1 F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®
2 or 1 - F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®
2 - F32T8 120V-277V Ultra Low Watt .60 BF <10% THD
1 - F32T8 277V “N”.87 BF ProLine®
2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 - F32T8 277V Normal Light .87 BF <10% THD UltraStart®
1 - F32T8 120V “N”.87 BF ProLine®
2 or 1 - F32T8 120V “N”.87 BF ProLine®
2 - F32T8 120V Normal Light .87 BF <10% THD UltraStart®
2 or 1 - F32T8 120V “N”.87 BF Residential ProLine®
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 F40 or F34T12 Rapid Start Electronic 120V “N” BF
2 F40 or F34T12 Rapid Start Electronic 120V “N” BF
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack
1 F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack
1 - F40T12 F40T12 120V Magnetic Ballast (412LSLHTCP)
1 - F40T12 F30T12 F48/25W 120V Magnetic Ballast (413CTCP)
2 - F28T5 PRS UNV 50/60 Hz
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
12 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15
BF A Can
2 - F28T5 PRS UNV 50/60 Hz
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
11 or 1 - F14-F35HE 120 to 277 UltraStart® PRS High Light 1.15
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 or 1 - F14-F35HE 120 to 277 UltraStart® PRS Normal Light .95
BF A Can
2 - F39T5HO PRS UNV 50/60 Hz
2 - F24T5HO PRS UNV 50/60 Hz
2 - F39T5HO PRS UNV 50/60 Hz

40
46
46
47
47
47
62
61
61
62
53
54
60
53
54
60
58
86
85
86
85
85
85
86
86
93
93
78
77
77
78
77
77
77
77
79
79
79

27

HID Electromagnetic
Ballasts

2
2
2
2
2
2
2
2
2
2

GE332MAX-N+

HID Electronic
Ballasts

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

71422

Compact Fluorescent
Ballasts

120-277

Linear Fluorescent Lamps
®

Sign
Ballasts

3

Prod Code
Page No

Fluorescent Ballast Long Description

T12
Fluorescent Ballasts

26

4
4
4
4
4
4
4
4
4
4
4
4

Ballast
Product
Code Ballast Description

T5
Fluorescent Ballasts

F32T8/WM
(cont)

120-277

Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

T8
Fluorescent Ballasts

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

Quick Reference
Guides

gelighting.com

Quick reference lamp to ballast selection guide (cont.)

Linear Fluorescent Lamps

F40T10

F40T12/
WMP

F48T8/HO
28

1

120-277

1

120-277

1
1

120-277
120

3
3
3
3
3
3
3

120-277
120-277
120-277
120-277
120-277
277
120

2
2

120-277
120-277

2
2
2
2
2
2
1
1
1
1
1

120-277
120-277
120-277
120-277
277
120
120-277
120-277
120-277
120-277
120-277

1
1
1
2
2
2
1
1
1
2
2
2
1

120-277
120-277
277
120-277
277
120
120-277
120
120
120-277
120-277
120-277
120-277

86
85
86
95
94
95
85
93
96
86
86
85
86
95
85
85
94
95
85
86
93
93
86
95
95
86
86
94
93

71423

GE432MAX-N+

4 or 3 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

44

71422

GE332MAX-N+

3 or 2 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®

42

49766

GE159MAX-N/ULTRA 1 - F96T8 120 to 277 “N” .87 BF UltraMax®

45

49775

GE232MAX-H/ULTRA 2 or 1 - F32T8 120 to 277 “H” 1.15 BF UltraMax®

39

71421
23671

GE232MAX-N+
GE-232-120-N

2 or 1 - F32T8 120 to 277 “N+” 1.0 BF UltraMax®
2 or 1 - F32T8 120V “N”.87 BF ProLine®

40
54

71723
30219
30262
30193
30193
23676
23675

GE432MAX-H/ULTRA
GE-432-MV-H
GE-432-MV-L
GE-432-MV-N
GE-432-MV-N
GE-432-277-N
GE-432-120-N

4 or 3 - F32T8 120 to 277 “H” 1.15 BF UltraMax®
4 or 3 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
4 or 3 - F32T8 277V “N”.87 BF ProLine®
4 or 3 - F32T8 120V “N”.87 BF ProLine®

43
49
50
50
50
56
56

F72T12/HO

49767
30176

GE259MAX-N/ULTRA 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax®
GE-286-HO-MV-N
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF

45
52

F72T8

71714
30199
30255
30192
23674
23673
30198
30198
72273
72275
72275

GE332MAX-H/ULTRA
GE-332-MV-H
GE-332-MV-L
GE-332-MV-N
GE-332-277-N
GE-332-120-N
GE-232-MV-H
GE-232-MV-H
GE-232-MV-L
GE-232-MV-N
GE-232-MV-N

3 or 2 - F32T8 120 to 277 “H” 1.15 BF UltraMax®
3 or 2 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
3 or 2 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
3 or 2 - F32T8 277V “N”.87 BF ProLine®
3 or 2 - F32T8 120V “N”.87 BF ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “L”.77 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F32T8 120 to 277 “N”.87 BF Multivolt ProLine®

41
48
48
49
55
55
46
46
47
47
47

49767
30176
23672
24108
86379
86360
24108
72110
89709
72109
72109
30176
30176

GE259MAX-N/ULTRA
GE-286-HO-MV-N
GE-232-277-N
GE-260-IS-MV-N
GEM296IS277IP
GEM296IS120IP
GE-260-IS-MV-N
GE140RS120-DIY
GEM140RS120DIY
GE296HO-MV-N
GE296HO-MV-N
GE-286-HO-MV-N
GE-286-HO-MV-N

2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F32T8 277V “N”.87 BF ProLine®
2 or 1 - F96T12 Instant Start 120 to 277
2 - F96T12 IS 277V Magnetic Ballast (827SLHTCP)
2 - F96T12 IS 120V Magnetic Ballast (806SLHTCP)
2 or 1 - F96T12 Instant Start 120 to 277
1 F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack
1 - F40T12 F30T12 F48/25W 120V Magnetic Ballast (413CTCP)
2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine®
2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine®
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF

45
52
54
87
98
98
87
86
93
89
89
52
52

See page 195 for warranty information.

F4T5

F54T5/HO

F54T5/WM

F58T8

F58T8
(cont)
F60T12
F60T12/HO
F60T8/HO
F64T12
F6T5

F72T12

F72T8/HO
F73T12/HO
F84T12
F84T12/HO
F8T5
F8T9

F96T12

F96T12/HO

1
4
4
3
3
2
2
2
2
1
1
1
1
4
3
2
2
1
1
4
3
2
2
2
1
1
1
2
1
2
2
2
1
2
1
1
2
2
2
1
1
1
2
2
2
2
2
2
2

277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
120-277
277
120
120-277
277
120
120-277
277
277
120
120
120
120-277

2

120-277

1
2
1
2
2
1
2
2
1
1
2
2
2
1
1
1
1
2
2
2
2
2
2
1

120-277
120-277
120-277
120
120-277
120-277
277
120
277
120
120-277
277
120
120-277
277
120
120-277
120-277
120-277
277
277
120
120
120-277

Magnetic - Preheat
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Magnetic - Preheat
Electronic - Multivolt Instant Start
Magnetic - Standard Instant Start
Magnetic - Standard Instant Start
Electronic - Multivolt Instant Start
Magnetic - Standard Instant Start
Magnetic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Preheat
Electronic - Program / Rapid Start
Electronic - Multivolt Instant Start
Magnetic - Standard Instant Start
Magnetic - Standard Instant Start
Electronic - Multivolt Instant Start
Magnetic - Standard Instant Start
Magnetic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start

See page 195 for warranty information.

87634
99649
29726
99649
29726
47542
99651
99649
29726
47542
99651
99649
29726
99649
99649
99651
99649
99651
99649
99649
99649
99651
30176
99649
99651
30176
99649
24108
24108
72109
72109
30176
30176
24108
24108
87634
24108
86379
86360
24108
86381
86372
72109
80163
86171
80664
80162
86164
72109

GEM1CF579PH277
GE454MVPS90-E
GE454MVPSN1
GE454MVPS90-E
GE454MVPSN1
B254PUNV-DGE1C
GE254MVPS90-F
GE454MVPS90-E
GE454MVPSN1
B254PUNV-DGE1C
GE254MVPS90-F
GE454MVPS90-E
GE454MVPSN1
GE454MVPS90-E
GE454MVPS90-E
GE254MVPS90-F
GE454MVPS90-E
GE254MVPS90-F
GE454MVPS90-E
GE454MVPS90-E
GE454MVPS90-E
GE254MVPS90-F
GE-286-HO-MV-N
GE454MVPS90-E
GE254MVPS90-F
GE-286-HO-MV-N
GE454MVPS90-E
GE-260-IS-MV-N
GE-260-IS-MV-N
GE296HO-MV-N
GE296HO-MV-N
GE-286-HO-MV-N
GE-286-HO-MV-N
GE-260-IS-MV-N
GE-260-IS-MV-N
GEM1CF579PH277
GE-260-IS-MV-N
GEM296IS277IP
GEM296IS120IP
GE-260-IS-MV-N
GEM196IS277IP
GEM196IS120IP
GE296HO-MV-N
B295SR277HP
GEM296HORS277IP
493B2
B295SR120HP
GEM296HORS120IP
GE296HO-MV-N

49767

GE259MAX-N/ULTRA 2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax®

49767
30176
30176
80664
24108
24108
80163
80162
87634
97498
24108
86379
86360
24108
86381
86372
72109
72109
72109
80163
86171
80162
86164
72109

®

GE259MAX-N/ULTRA
GE-286-HO-MV-N
GE-286-HO-MV-N
493B2
GE-260-IS-MV-N
GE-260-IS-MV-N
B295SR277HP
B295SR120HP
GEM1CF579PH277
GE240RS120
GE-260-IS-MV-N
GEM296IS277IP
GEM296IS120IP
GE-260-IS-MV-N
GEM196IS277IP
GEM196IS120IP
GE296HO-MV-N
GE296HO-MV-N
GE296HO-MV-N
B295SR277HP
GEM296HORS277IP
B295SR120HP
GEM296HORS120IP
GE296HO-MV-N

1 - CFT579Q9W/G23 Preheat 277 (4205F2P)
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4,3,2 or 1 - F54T5HO 120-277V UltraStart® PRS Stick Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4,3,2 or 1 - F54T5HO 120-277V UltraStart® PRS Stick Can
2 - F54T5HO PRS UNV 50/60 Hz
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4,3,2 or 1 - F54T5HO 120-277V UltraStart® PRS Stick Can
2 - F54T5HO PRS UNV 50/60 Hz
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4,3,2 or 1 - F54T5HO 120-277V UltraStart® PRS Stick Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 or 1 - F96T12 Instant Start 120 to 277
2 or 1 - F96T12 Instant Start 120 to 277
2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine®
2 or 1- F96T12 HO RS 120 to 277 Multivolt ProLine®
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T12 Instant Start 120 to 277
2 or 1 - F96T12 Instant Start 120 to 277
1 - CFT579Q9W/G23 Preheat 277 (4205F2P)
2 or 1 - F96T12 Instant Start 120 to 277
2 - F96T12 IS 277V Magnetic Ballast (827SLHTCP)
2 - F96T12 IS 120V Magnetic Ballast (806SLHTCP)
2 or 1 - F96T12 Instant Start 120 to 277
1 - F96T12 IS 277 Magnetic Ballast (828BRTCP)
1 - F96T12 IS 120 Magnetic Ballast (822BRTCP)
2 or 1- F96T12 HO RS 120 to 277 Multivolt ProLine®
2 - F96T12HOES RS 277
2 - F96T12HO RS 277V Magnetic Ballast (487SLHTCP)
2 - F73T12/BL/HO Suntan 120 Magnetic Ballast
2 - F96T12HOES RS 120
2 - F96T12HO F72T12HO RS 120V Magnetic Ballast (480SLHTCP)
2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine®

2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 - F73T12/BL/HO Suntan 120 Magnetic Ballast
2 or 1 - F96T12 Instant Start 120 to 277
2 or 1 - F96T12 Instant Start 120 to 277
2 - F96T12HOES RS 277
2 - F96T12HOES RS 120
1 - CFT579Q9W/G23 Preheat 277 (4205F2P)
2 F40 or F34T12 Rapid Start Electronic 120V “N” BF
2 or 1 - F96T12 Instant Start 120 to 277
2 - F96T12 IS 277V Magnetic Ballast (827SLHTCP)
2 - F96T12 IS 120V Magnetic Ballast (806SLHTCP)
2 or 1 - F96T12 Instant Start 120 to 277
1 - F96T12 IS 277 Magnetic Ballast (828BRTCP)
1 - F96T12 IS 120 Magnetic Ballast (822BRTCP)
2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine®
2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine®
2 or 1- F96T12 HO RS 120 to 277 Multivolt ProLine®
2 - F96T12HOES RS 277
2 - F96T12HO RS 277V Magnetic Ballast (487SLHTCP)
2 - F96T12HOES RS 120
2 - F96T12HO F72T12HO RS 120V Magnetic Ballast (480SLHTCP)
2 or 1- F96T12 HO RS 120 to 277 Multivolt ProLine®

128
81
81
81
81
80
80
81
81
80
80
81
81
81
81
80
81
80
81
81
81
80
52
81
80
52
81
87
87
89
89
52
52
87
87
128
87
98
98
87
97
97
89
88
99
100
88
99
89
45
45
52
52
100
87
87
88
88
128
85
87
98
98
87
97
97
89
89
89
88
99
88
99
89
29

HID Electromagnetic
Ballasts

F48T12/HO

120-277

3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 - F40T12 RS 277V Magnetic Ballast (443LSLHTCP)
2 - F40T12 F40T12 120V Magnetic Ballast (420LTCP)
2 - F40T12 RS 120V Magnetic Ballast (446LSLHTCP)
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
1 - F40T12 F40T12 120V Magnetic Ballast (412LSLHTCP)
2 - F40T12 F40T10 220V Magnetic Ballast (754LTCP)
1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 - F40T12 RS 277V Magnetic Ballast (443LSLHTCP)
2 F40 or F34T12 Rapid Start Electronic 120V “N” BF
2 F40 or F34T12 Rapid Start Electronic 120V “N” BF
2 - F40T12 F40T12 120V Magnetic Ballast (420LTCP)
2 - F40T12 RS 120V Magnetic Ballast (446LSLHTCP)
2 or 1 - F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
1 F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack
1 - F40T12 F40T12 120V Magnetic Ballast (412LSLHTCP)
1 - F40T12 F30T12 F48/25W 120V Magnetic Ballast (413CTCP)
1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack
2 - F40T12 RS 277V Magnetic Ballast (443LSLHTCP)
2 - F40T12 RS 120V Magnetic Ballast (446LSLHTCP)
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
3 or 2 - F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
2 - F40T12 F40T12 120V Magnetic Ballast (420LTCP)
1 - F40T12 F40T12 120V Magnetic Ballast (412LSLHTCP)

HID Electronic
Ballasts

F48T12/
25W

2

GE-340-RS-MV-N
GE-240-RS-MV-N
GE-340-RS-MV-N
GEM240RS277IP
GEM240HRS120DIY
GEM240RS120IP
GE-240-RS-MV-N
GEM140HRS120DIY
GEM240RS220IP
GE140RS120-DIY
GE-340-RS-MV-N
GE-240-RS-MV-N
GE-340-RS-MV-N
GEM240RS277IP
GE240RS120
GE240RS120
GEM240HRS120DIY
GEM240RS120IP
GE-240-RS-MV-N
GE140RS120-DIY
GEM140HRS120DIY
GEM140RS120DIY
GE140RS120-DIY
GEM240RS277IP
GEM240RS120IP
GE-340-RS-MV-N
GE-340-RS-MV-N
GEM240HRS120DIY
GEM140HRS120DIY

Prod Code
Page No

Fluorescent Ballast Long Description

Compact Fluorescent
Ballasts

F48T12

120-277

Linear Fluorescent Lamps

24109
24107
24109
86124
89710
86139
24107
89714
86341
72110
24109
24107
24109
86124
97498
97498
89710
86139
24107
72110
89714
89709
72110
86124
86139
24109
24109
89710
89714

Ballast
Product
Code Ballast Description

Sign
Ballasts

F40T8

3

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Magnetic - Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Multivolt Instant Start
Magnetic - Standard Instant Start
Magnetic - Standard Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

Fluorescent Ballast Long Description

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

T12
Fluorescent Ballasts

F40T12/
WM

120-277
120-277
120-277
277
120
120
120-277
120
220
120
120-277
120-277
120-277
277
120
120
120
120
120-277
120
120
120
120
277
120
120-277
120-277
120
120

Prod Code
Page No

T5
Fluorescent Ballasts

F40T12

3
2
2
2
2
2
1
1
2
1
3
2
2
2
2
2
2
2
1
1
1
1
1
2
2
3
2
2
1

Ballast
Product
Code Ballast Description

T8
Fluorescent Ballasts

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

Quick Reference
Guides

gelighting.com

Quick reference lamp to ballast selection guide (cont.)

Linear Fluorescent Lamps
F96T12/
HO/WM
F96T12/
WM
F96T12/
WMP

F96T8/HO/
WM

1
1

120-277
120-277

1
1
1
1
1
2
1
2
2
2
2

120-277
120-277
120-277
277
120
120-277
120-277
277
277
120
120

2
2
2
2
2

120-277
120-277
120-277
277
120

1
1

120-277
120-277

1
1
1
1
1

120-277
120-277
120-277
277
120

2
2
2
2
2
F96T8/
WMP

120-277
120-277
120-277
277
120
120-277
120-277

1
1
1
1
1

120-277
120-277
120-277
277
120

2 or 1 - F96T12 HO RS 120 to 277 Multivolt ProLine®
2 or 1- F96T12 HO RS 120 to 277 Multivolt ProLine®
2 or 1 - F96T12 Instant Start 120 to 277
2 - F96T12 IS 277V Magnetic Ballast (827SLHTCP)
2 - F96T12 IS 120V Magnetic Ballast (806SLHTCP)
2 or 1 - F96T12 Instant Start 120 to 277
1 - F96T12 IS 277 Magnetic Ballast (828BRTCP)
1 - F96T12 IS 120 Magnetic Ballast (822BRTCP)
2 or 1 - F96T12 Instant Start 120 to 277
2 or 1 - F96T12 Instant Start 120 to 277
®

2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax
2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T8 277v “N”.87 BF ProLine®
2 or 1 - F96T8 120v Normal Light .87 BF ProLine®

89
89
87
98
98
87
97
97
87
87

49767
30194
30176
23678
23677

GE259MAX-N/ULTRA
GE-259-MV-N
GE-286-HO-MV-N
GE-259-277-N
GE-259-120-N

49766
30195

GE159MAX-N/ULTRA 1 - F96T8 120 to 277 “N” .87 BF UltraMax®
GE-159-MV-N
1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine®

49767
30194
30176
23678
23677
30176
30176
80163
86171
80162
86164

GE259MAX-N/ULTRA
GE-259-MV-N
GE-286-HO-MV-N
GE-259-277-N
GE-259-120-N
GE-286-HO-MV-N
GE-286-HO-MV-N
B295SR277HP
GEM296HORS277IP
B295SR120HP
GEM296HORS120IP

2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T8 277v “N”.87 BF ProLine®
2 or 1 - F96T8 120v Normal Light .87 BF ProLine®
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 - F96T12HOES RS 277
2 - F96T12HO RS 277V Magnetic Ballast (487SLHTCP)
2 - F96T12HOES RS 120
2 - F96T12HO F72T12HO RS 120V Magnetic Ballast (480SLHTCP)

45
51
52
57
57
52
52
88
99
88
99

49767
30194
30176
23678
23677

GE259MAX-N/ULTRA
GE-259-MV-N
GE-286-HO-MV-N
GE-259-277-N
GE-259-120-N

2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T8 277v “N”.87 BF ProLine®
2 or 1 - F96T8 120v Normal Light .87 BF ProLine®

45
51
52
57
57

49766
30195

GE159MAX-N/ULTRA 1 - F96T8 120 to 277 “N” .87 BF UltraMax®
GE-159-MV-N
1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine®

49767
30194
30176
23678
23677

GE259MAX-N/ULTRA
GE-259-MV-N
GE-286-HO-MV-N
GE-259-277-N
GE-259-120-N

45
51
52
57
57
45
51

Circleline Fluorescent Lamps

FC12T5HO

FC12T9

FC16T9

FC6T9
FC8T9

49767
30194
30176
23678
23677

GE259MAX-N/ULTRA
GE-259-MV-N
GE-286-HO-MV-N
GE-259-277-N
GE-259-120-N

2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T8 277v “N”.87 BF ProLine®
2 or 1 - F96T8 120v Normal Light .87 BF ProLine®

CFM36W/
2G10
CFM42W
CFM57W
CFM70W
CFQ13W/
2P
CFQ13W/
G24q

CFQ18W/
G24q

45
51

®

49766
30195

GE159MAX-N/ULTRA 1 - F96T8 120 to 277 “N” .87 BF UltraMax
GE-159-MV-N
1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine®

49767
30194
30176
23678
23677

GE259MAX-N/ULTRA
GE-259-MV-N
GE-286-HO-MV-N
GE-259-277-N
GE-259-120-N

2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T8 277v “N”.87 BF ProLine®
2 or 1 - F96T8 120v Normal Light .87 BF ProLine®

45
51
52
57
57
45
51
52
57
57

CFQ26W/
G24q

45
51
45
51
52
57
57

CFS16W/
GR10q

CFS21W/
GR10q

CFT13W/2P

See page 195 for warranty information.

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start

99649
99649
47542
99649
99651
47542
99649
99651
89717
97498
97498
89720
97499
89720

GE454MVPS90-E
GE454MVPS90-E
B254PUNV-DGE1C
GE454MVPS90-E
GE254MVPS90-F
B254PUNV-DGE1C
GE454MVPS90-E
GE254MVPS90-F
GEM1FC12T9RS120
GE240RS120
GE240RS120
GEM1FC16T9RS120
GE240RS120
GEM1FC16T9RS120

1

120-277 Electronic - Program / Rapid Start

71444

GEC226-MVPS-XX

1
1
2
1

120-277
120
120
120

71445
86227
89717
86227

GEC226-MVPS-3W
GEM1FC8T9RS120IP
GEM1FC12T9RS120
GEM1FC8T9RS120IP

Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Rapid Start
Magnetic - Rapid Start

2
1
2
1
1
1
2
1
2
2
1
1
1
1
2
2
1
1
2
2

120-277
120-277
120-277
120-277
120-277
120-277
277
120
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
277
120-277

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Preheat
Magnetic - Preheat
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Preheat
Electronic - Program / Rapid Start

47506
47506
47506
47506
47506
47506
87655
87533
71430
71429
71430
71429
71430
71429
71434
71433
71434
71433
87700
47506

C242UNVBES-IP
C242UNVBES-IP
C242UNVBES-IP
C242UNVBES-IP
C242UNVBES-IP
C242UNVBES-IP
GEM2CF13PH277
GEM1CF13PH120
GEC213-MVPS-3W
GEC213-MVPS-XX
GEC213-MVPS-3W
GEC213-MVPS-XX
GEC213-MVPS-3W
GEC213-MVPS-XX
GEC218-MVPS-3W
GEC218-MVPS-XX
GEC218-MVPS-3W
GEC218-MVPS-XX
GEM2CF24PH277
C242UNVBES-IP

2

120-277 Electronic - Program / Rapid Start

71445

GEC226-MVPS-3W

2
1
1
1
1

120-277
120-277
120-277
120-277
120-277

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

71444
71434
71434
71433
71433

GEC226-MVPS-XX
GEC218-MVPS-3W
GEC218-MVPS-3W
GEC218-MVPS-XX
GEC218-MVPS-XX

1

120-277 Electronic - Program / Rapid Start

71445

GEC226-MVPS-3W

1
2
2
2
2
1
1
1
1
2
2

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

71444
71430
71429
71434
71433
71430
71430
71429
71429
71434
71433

GEC226-MVPS-XX
GEC213-MVPS-3W
GEC213-MVPS-XX
GEC218-MVPS-3W
GEC218-MVPS-XX
GEC213-MVPS-3W
GEC213-MVPS-3W
GEC213-MVPS-XX
GEC213-MVPS-XX
GEC218-MVPS-3W
GEC218-MVPS-XX

2

120-277 Electronic - Program / Rapid Start

71445

GEC226-MVPS-3W

2
1
1
2
1
1
2
1

120-277
120-277
120-277
120-277
120-277
120-277
277
120

71444
71434
71433
47506
71434
71433
87655
87533

GEC226-MVPS-XX
GEC218-MVPS-3W
GEC218-MVPS-XX
C242UNVBES-IP
GEC218-MVPS-3W
GEC218-MVPS-XX
GEM2CF13PH277
GEM1CF13PH120

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Preheat
Magnetic - Preheat

See page 195 for warranty information.

4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 - F54T5HO PRS UNV 50/60 Hz
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
2 - F54T5HO PRS UNV 50/60 Hz
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
2 FC12T9 RS 120V Magnetic Ballast (449LRWSTCP)
5 - F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12
4 - F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12
2 - FC12T9 FC16T9 FC8T9 FC12T9 120V Magnetic (726VLHWSTCP)
3 - F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12
2 - FC12T9 FC16T9 FC8T9 FC12T9 120V Magnetic (726VLHWSTCP)
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V
ProLine® PS
1 - FC8T9 RS 120V Magnetic Ballast (547RSWSTCP)
2 FC12T9 RS 120V Magnetic Ballast (449LRWSTCP)
1 - FC8T9 RS 120V Magnetic Ballast (547RSWSTCP)
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2 - CFT/Q13W/GX23 Preheat 277 (4214PBES)
1 - CFT/Q13W/GX23 Preheat 120 (4111H2P)
2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit
2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS
2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit
2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS
2 - CFQ26W/G24d Preheat 277 (4226PBES)
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V
ProLine® PS
2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit
2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit
2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS
2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V
ProLine® PS
2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit
2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS
2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit
2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V
ProLine® PS
2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit
2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit
2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS
2 - CFT/Q13W/GX23 Preheat 277 (4214PBES)
1 - CFT/Q13W/GX23 Preheat 120 (4111H2P)

81
81
80
81
80
80
81
80
92
85
85
91
91
124
124
91
92
91
124
124
124
124
124
124
129
128
123
123
123
123
123
123
123
123
123
123
129
124
124
124
123
123
123
123
124
124
123
123
123
123
123
123
123
123
123
123
124
123
123
123
123
123
129
128
31

HID Electromagnetic
Ballasts

CFS28W/
GR10q

30

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120
120
120
120
120
120

Compact Fluorescent Lamps

CFQ26W/2P
2 or 1 - F96T8 120 to 277 “N” .87 BF UltraMax®
2 or 1 - F96T8 120 to 277 “N”.87 BF Multivolt ProLine®
2 or 1 - F96T8HO IS 120 to 277 “N”.87 BF
2 or 1 - F96T8 277v “N”.87 BF ProLine®
2 or 1 - F96T8 120v Normal Light .87 BF ProLine®

4
3
2
2
2
1
1
1
2
2
1
1
1
1

Prod Code
Page No

HID Electronic
Ballasts

1
1

GE296HO-MV-N
GE296HO-MV-N
GE-260-IS-MV-N
GEM296IS277IP
GEM296IS120IP
GE-260-IS-MV-N
GEM196IS277IP
GEM196IS120IP
GE-260-IS-MV-N
GE-260-IS-MV-N

Fluorescent Ballast Long Description

Compact Fluorescent
Ballasts

120-277
120-277
120-277
277
120

72109
72109
24108
86379
86360
24108
86381
86372
24108
24108

Ballast
Product
Code Ballast Description

Sign
Ballasts

F96T8/WM

2
2
2
2
2

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Multivolt Instant Start
Magnetic - Standard Instant Start
Magnetic - Standard Instant Start
Electronic - Multivolt Instant Start
Magnetic - Standard Instant Start
Magnetic - Standard Instant Start
Electronic - Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - High Efficiency
Multivolt Instant Start
Electronic - Multivolt Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start

Fluorescent Ballast Long Description

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

T12
Fluorescent Ballasts

F96T8/HO

120-277
120-277
120-277
277
120
120-277
277
120
120-277
120-277

Prod Code
Page No

T5
Fluorescent Ballasts

F96T8

2
2
2
2
2
1
1
1
2
1

Ballast
Product
Code Ballast Description

T8
Fluorescent Ballasts

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

Quick Reference
Guides

gelighting.com

Quick reference lamp to ballast selection guide (cont.)

Compact Fluorescent Lamps
CFT5W/2P
CFT7W/2P
CFT9W/2P

CFTR13W/
GX24q

CFTR26W/
2P

CFTR26W/
GX24q

CFTR42W/
GX24q
FC12T5

FT24W/
2G11

FT39W/4P

87634
87634
87634
71430
71429
71430
71429
71434
71433
71430
71429
71434
71433

GEM1CF579PH277
GEM1CF579PH277
GEM1CF579PH277
GEC213-MVPS-3W
GEC213-MVPS-XX
GEC213-MVPS-3W
GEC213-MVPS-XX
GEC218-MVPS-3W
GEC218-MVPS-XX
GEC213-MVPS-3W
GEC213-MVPS-XX
GEC218-MVPS-3W
GEC218-MVPS-XX

1 - CFT579Q9W/G23 Preheat 277 (4205F2P)
1 - CFT579Q9W/G23 Preheat 277 (4205F2P)
1 - CFT579Q9W/G23 Preheat 277 (4205F2P)
2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit
2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS
2 or 1 - CFQ13W/G24q 120-277V ProLine® PS 3-Way Kit
2 or 1 - CFQ13W/G24q Bottom Exit 120-277V ProLine® PS
2 or 1 - CFQ18W/G24q 120-277V ProLine® PS 3 Way Kit
2 or 1 - CFQ18W/G24q Bottom Exit 120-277 ProLine® PS

128
128
128
123
123
123
123
123
123
123
123
123
123

2
2

277
Magnetic - Preheat
120-277 Electronic - Program / Rapid Start

87700
47506

GEM2CF24PH277
C242UNVBES-IP

129
124

2

120-277 Electronic - Program / Rapid Start

71445

GEC226-MVPS-3W

2

120-277 Electronic - Program / Rapid Start

71444

GEC226-MVPS-XX

1

120-277 Electronic - Program / Rapid Start

71445

GEC226-MVPS-3W

1
2

120-277 Electronic - Program / Rapid Start
120-277 Electronic - Program / Rapid Start

71444
47506

GEC226-MVPS-XX
C242UNVBES-IP

1

120-277 Electronic - Program / Rapid Start

71445

GEC226-MVPS-3W

1

120-277 Electronic - Program / Rapid Start

71444

GEC226-MVPS-XX

1

120-277 Electronic - Program / Rapid Start

71445

GEC226-MVPS-3W

1
2
1
2

120-277
120-277
120-277
120-277

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

71444
47506
47506
47506

GEC226-MVPS-XX
C242UNVBES-IP
C242UNVBES-IP
C242UNVBES-IP

2 - CFQ26W/G24d Preheat 277 (4226PBES)
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V
ProLine® PS
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V
ProLine® PS
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs

1&1
2
1
2

120-277
120-277
120-277
120-277

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

47506
47534
47534
47506

C242UNVBES-IP
B224PUNV-COG1C
B224PUNV-COG1C
C242UNVBES-IP

2

120-277 Electronic - Program / Rapid Start

71445

GEC226-MVPS-3W

2
2
1
4
3
2
2
2
2
2
2
2
1
1
1
1
1
1
3
3
2
2
2
2
2
2
1
1
1

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120
120
120-277
120-277
120-277
120-277
120-277
120-277
277
120
120-277
277
277
120
120
120
120-277
277
120

71444
47534
47534
99649
99649
47540
47542
47506
99651
99649
97498
87623
47534
47534
47540
47542
99651
99649
80691
80690
80683
80681
80691
80680
80690
87625
80683
80681
80680

GEC226-MVPS-XX
B224PUNV-COG1C
B224PUNV-COG1C
GE454MVPS90-E
GE454MVPS90-E
B239PUNV-DOG1C
B254PUNV-DGE1C
C242UNVBES-IP
GE254MVPS90-F
GE454MVPS90-E
GE240RS120
GEM2FT36RS120
B224PUNV-COG1C
B224PUNV-COG1C
B239PUNV-DOG1C
B254PUNV-DGE1C
GE254MVPS90-F
GE454MVPS90-E
C340SI277RH-IP
C340SI120RH-IP
C240PUNVHP-B-IP
C240SI277RH-IP
C340SI277RH-IP
C240SI120RH-IP
C340SI120RH-IP
GEM2FT40RS120
C240PUNVHP-B-IP
C240SI277RH-IP
C240SI120RH-IP

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start
Magnetic - Rapid Start
Electronic - Program / Rapid Start
Electronic - Standard Instant Start
Electronic - Standard Instant Start

2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2 - F24T5HO PRS UNV 50/60 Hz
2 - F24T5HO PRS UNV 50/60 Hz
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2 - CFQ26W, FT24 or 1-42W, CFTR32 3 Way Mounting Kit 120-277V
ProLine® PS
2 - CFQ26W, FT24 or 1-42W, CFTR32 Bottom Exit 120-277V
ProLine® PS
2 - F24T5HO PRS UNV 50/60 Hz
2 - F24T5HO PRS UNV 50/60 Hz
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 - F39T5HO PRS UNV 50/60 Hz
2 - F54T5HO PRS UNV 50/60 Hz
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
6 - F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12
2 - FT36W/2G11 RS 120 (4150P)
2 - F24T5HO PRS UNV 50/60 Hz
2 - F24T5HO PRS UNV 50/60 Hz
2 - F39T5HO PRS UNV 50/60 Hz
2 - F54T5HO PRS UNV 50/60 Hz
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
3 - FT40W/2G11 IS 277
3 - FT40W/2G11 IS 120
2 or 1 - FT40W2G11 PS UNV
2 - FT40W/2G11 IS 277
3 - FT40W/2G11 IS 277
2 - FT40W/2G11 IS 120
3 - FT40W/2G11 IS 120
2 - FT40W/2G11RS RS 120 (4152P)
2 or 1 - FT40W2G11 PS UNV
2 - FT40W/2G11 IS 277
2 - FT40W/2G11 IS 120

Compact Fluorescent Lamps
FT50W/
2G11

FT55W/
2G11

4
3
2
2
1
1
4
3
2
2
1
1
1
1
1

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

99649
99649
99651
99649
99651
99649
99649
99649
99651
99649
47542
47542
47506
99651
99649

GE454MVPS90-E
GE454MVPS90-E
GE254MVPS90-F
GE454MVPS90-E
GE254MVPS90-F
GE454MVPS90-E
GE454MVPS90-E
GE454MVPS90-E
GE254MVPS90-F
GE454MVPS90-E
B254PUNV-DGE1C
B254PUNV-DGE1C
C242UNVBES-IP
GE254MVPS90-F
GE454MVPS90-E

4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can
2 - F54T5HO PRS UNV 50/60 Hz
2 - F54T5HO PRS UNV 50/60 Hz
2- 42 / 36 / 32 / 26 / 24 watt CFL UNV Bottom Exit w/Studs
2 or 1 - F54T5HO 120 to 277 UltraStart® PRS High Temp F Can
4-1 - F54T5HO 120 to 277 UltraStart® PRS High Temp E Can

81
81
80
81
80
81
81
81
80
81
80
80
124
80
81

124
124
124
124
124
124
124
124
124
124
124
123
123
124
124
124
79
79
81
81
79
80
124
80
81
85
130
79
79
79
80
80
81
127
126
125
126
127
125
126
130
125
126
125

See page 195 for warranty information.

See page 195 for warranty information.

33

HID Electromagnetic
Ballasts

32

Magnetic - Preheat
Magnetic - Preheat
Magnetic - Preheat
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start
Electronic - Program / Rapid Start

Prod Code
Page No

HID Electronic
Ballasts

FT40W/4P

277
277
277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

Fluorescent Ballast Long Description

Compact Fluorescent
Ballasts

FT24W/4P

1
1
1
2
2
1
1
2
2
1
1
1
1

Ballast
Product
Code Ballast Description

Sign
Ballasts

FC9T5
FC9T5 &
FC12T5
FT24W/
2G10

Fluorescent Ballast Long Description

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

T12
Fluorescent Ballasts

CFTR32W/
GX24q

Prod Code
Page No

T5
Fluorescent Ballasts

CFTR18W/
GX24q

Ballast
Product
Code Ballast Description

T8
Fluorescent Ballasts

# of
Lamp Type Lamps Voltage Fluorescent Ballast Type

Quick Reference
Guides

gelighting.com

Quick reference lamp to ballast selection guide (cont.)
Lamp
Type

Use with ANSI
Lamp Types Wattage

PC

New GE Description Circuit Type

120/208/240/277
120/208/240/277
120/480
120/208/240/277
120/277
120/277
120/480
120/208/240/277
120/480
120/208/240/277
120/277
120/480
120/208/240/277
120/480
120/208/240/277
120/480
120/208/240/277
120/480
120/208/240/277
120/480
120/208/240/277
120/277
120/208/240/277/480
120/208/240/277
120/277
120/208/240/277/480
120/208/240/277/480
120/208/240/277
120/277
120/277
120/480
120/208/240/277/480
120/208/240/277
120/480
120/208/240/277/480
120/208/240/277
120/480
120/208/240/277
120
120
120
120
120
120
120-277
120
120
120
120-277
120
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120/480
120/208/240/277
120/480
120/208/240/277
208-277
208-277
208-277
208-277
120/480
120/208/240/277
208-277
208-277
120/480
120/208/240/277
208-277
208-277
208-277
208-277
120/480
120/208/240/277
120/277/347

6MFD 280V
6MFD 280V
8MFD 280V
8MFD 280V
N/A
N/A
8MFD 280V
8MFD 280V
12MFD 280V
12MFD 280V
N/A
12MFD 280V
12MFD 280V
12MFD 280V
12MFD 280V
16MFD 280V
16MFD 280V
16MFD 280V
16MFD 280V
16MFD 280V
16MFD 280V
N/A
10MFD 400V
10MFD 400V
N/A
15MFD 400V
15MFD 400V
15MFD 400V
N/A
N/A
24MFD 400V
24MFD 400V
24MFD 400V
24MFD 480V
24MFD 480V
24MFD 480V
32MFD 525V
32MFD 525V
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
10MFD 400V
10MFD 400V
10MFD 400V
10MFD 400V
N/A
N/A
N/A
N/A
15MFD 400V
15MFD 400V
N/A
N/A
15MFD 400V
15MFD 400V
N/A
N/A
N/A
N/A
21MFD 345V
21MFD 345V
21MFD 345V

MH350-1A
MH350-1A
MH350-1A
MH350-1A
N/A
N/A
MH350-1A
MH350-1A
MH350-1A
MH350-1A
N/A
MH350-1A
MH350-1A
MH350-1A
MH350-1A
MH350-1A
MH350-1A
MH350-1A
MH350-1A
MH350-1A
MH350-1A
N/A

4.25x4.75
4.25x4.75
4.25x4.75
4.25x4.75

4.25x4.75
4.25x4.75
4.25x4.75

N/A

N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
MH350-1A
MH350-1A
MH350-1A
MH350-1A
N/A
N/A
N/A
N/A
MH350-1A
MH350-1A
N/A
N/A
MH350-1A
N/A
N/A
N/A
N/A
MH350-1A
MH350-1A
MH350-1A

144
144
145
144
174
174
145
144
146
145
175
146
145
146
145
147
146
147
146
147
146
175
147
148
176
149
150
149
176
177
151
151
152
152
153
153
154
135
135
136
136
136
136
137
136
136
136
137
136
137
137
137
137
138
138
138
155
155
155
155
139
139
139
139
156
156
139
139
156
156
139
139
139
139
157
157
158

See page 195 for warranty information.

PC

New GE Description Circuit Type

Frame Size

High Intensity Discharge (HID) Lamps

Pulse
Start
(cont)

High
Pressure
Sodium

Mercury

M154
M154
M154
M154
M154
CMH350
CMH350
M131
M131
M131
M131
CMH400
CMH400
M135
M135
M135
M135
M155
M155
M155
M155
M149
M149
M141
M141
S68
S62
S62
S62
S62
S54
S54
S55
S55
S55
S50
S50
S51
S51
S51
S52
S52
S52
H39
H39
H37
H37
H37
H33
H33
H33
H36
H36
H36

320
320
320
320
320
350
350
350
350
350
350
400
400
400
400
400
400
400
400
400
400
750
750
1000
1000
50
70
70
70
70
100
100
150
150
150
250
250
400
400
400
1000
1000
1000
175
175
250
250
250
400
400
400
1000
1000
1000

29377
89646
86952
86959
86968
29377
89646
29377
89646
86984
86984
29377
89646
29377
89646
86999
87008
29377
89646
87008
86999
46936
46934
72282
72281
87152
86596
86605
86456
86587
87068
87074
86606
87087
87094
87214
87121
87198
87215
87164
87048
87218
87056
87210
86741
87211
87212
86765
86803
72300
72149
86650
87213
86655

GE-MH-250-400-MA
eHID
GEMH250-400MV50 eHID Dim
GEP32048TAC4-5
CWA
GEP320MLTAC4-5
CWA
GEP320TRIAC4-5
CWA
GE-MH-250-400-MA
eHID
GEMH250-400MV50 eHID Dim
GE-MH-250-400-MA
eHID
GEMH250-400MV50 eHID Dim
GEP350277RCE-5
RX-NPF
GEP350MLTAC4-5
CWA
GE-MH-250-400-MA
eHID
GEMH250-400MV50 eHID Dim
GE-MH-250-400-MA
eHID
GEMH250-400MV50 eHID Dim
GEP40048TAC4-5
CWA
GEP400MLTAC4-5
CWA
GE-MH-250-400-MA
eHID
GEMH250-400MV50 eHID Dim
GEP400MLTAC4-5
CWA
GEP40048TAC4-5
CWA
GEP75048TAC5-5
CWA
GEP750MLTAC5-5
CWA
GEP1000ML5AC5-5
CWA
GEP1000MLTAC5-5
CWA
GES50MLTLC3D-5
HX-HPF
12210237CTC000I
HX-HPF
1233142U000I
R-HPF, R-NPF
GES7048TLC3D-5
HX-HPF
GES70MLTLC3D-5
HX-HPF
GES10048TLC3D-5
HX-HPF
GES100MLTLC3D-5
HX-HPF
1233154U000I
R-NPF
GES15048TLC3D-5
HX-HPF
GES150MLTLC3D-5
HX-HPF
GES250ML5AC4-5
CWA
GES250MLTAC4-5
CWA
GES40048TAC4-5
CWA
GES400ML5AC4-5
CWA
GES400MLTAC4-5
CWA
GES100048TAC5-5
CWA
GES1000ML5AC5-5
CWA
GES1000MLTAC5-5
CWA
GEM175ML5AC3-5
CWA
GEM175MLTAC3-5
CWA
GEM250ML5AC3-5
CWA
GEM250ML5AC4-5
CWA
GEM250MLTAC3-5
CWA
GEM40048TAC4-5
CWA
GEM400ML5AA4-5
CWA
GEM400MLTAA4-5
CWA
GEM100048TAC5-5
CWA
GEM1000ML5AC5-5
CWA
GEM1000MLTAC5-5
CWA

4.25x4.75
4.25x4.75
4.25x4.75

3.75x4.5
4.25x4.75

4.25x4.75
4.25x4.75
4.25x4.75
4.25x4.75
4.25x6.00
4.25x6.00
4.25x6.00
4.25x6.00
3x4
F-Can
2.81x3.94
3x4
3x4
3x4
3x4
2.81x3.94
3x4
3x4
4.25x4.75
4.25x4.75
4.25x4.75
4.25x4.75
4.25x4.75
4.25x6.00
4.25x6.00
4.25x6.00
3x4
3x4
3x4
4.25x4.75
3x4
4.25x4.75
4.25x4.75
4.25x4.75
4.25x6.00
4.25x6.00
4.25x6.00

Voltage

Cap.

Ignitor

208-277
208-277
120/480
120/208/240/277
120/277/347
208-277
208-277
208-277
208-277
277
120/208/240/277
208-277
208-277
208-277
208-277
120/480
120/208/240/277
208-277
208-277
120/208/240/277
120/480
120/480
120/208/240/277
120/208/240/277/480
120/208/240/277
120/208/240/277
120/277
120
120/480
120/208/240/277
120/480
120/208/240/277
120
120/480
120/208/240/277
120/208/240/277/480
120/208/240/277
120/480
120/208/240/277/480
120/208/240/277
120/480
120/208/240/277/480
120/208/240/277
120/208/240/277/480
120/208/240/277
120/208/240/277/480
120/208/240/277/480
120/208/240/277
120/480
120/208/240/277/480
120/208/240/277
120/480
120/208/240/277/480
120/208/240/277

N/A
N/A
21MFD 345V
21MFD 345V
21MFD 345V
N/A
N/A
N/A
N/A
22.5MFD 345V
22.5MFD 345V
N/A
N/A
N/A
N/A
24MFD 400V
24MFD 400V
N/A
N/A
24MFD 400V
24MFD 400V
24MFD 400V
24MFD 400V
24MFD 480V
24MFD 480V
5MFD 280V
N/A

N/A
N/A
MH350-1A
MH350-1A
MH350-1A
N/A
N/A
N/A
N/A
MH350-1A
MH350-1A
N/A
N/A
N/A
N/A
MH350-1A
MH350-1A
N/A
N/A
MH350-1A
MH350-1A
MH750-1B
MH750-1B
HPS1000-4B
HPS1000-4B
HPS150-3A
N/A

7MFD 300V
7MFD 300V
10MFD 280V
10MFD 280V

HPS150-3A
HPS150-3A

14MFD 280V
14MFD 280V
35MFD 240V
35MFD 240V
55MFD 240V
55MFD 240V
55MFD 240V
26MFD 525V
26MFD 525V
26MFD 525V
10MFD 400V
10MFD 400V
15MFD 400V
15MFD 400V
15MFD 400V
24MFD 400V
24MFD 400V
24MFD 400V
24MFD 480V
24MFD 480V
24MFD 480V

HPS150-3A
HPS150-3A
HPS150-3A
HPS400-3A
HPS400-3A
HPS400-3A
HPS400-3A
HPS400-3A
HPS24
HPS1000-4B
HPS1000-4B

Prod Code
Page No
139
139
157
157
158
139
139
139
139
158
158
139
139
139
139
159
159
139
139
159
159
160
160
161
161
162
178
178
163
162
164
163
179
165
164
166
166
168
167
167
168
169
169
147
148
149
150
149
151
150
151
152
152
153

See page 195 for warranty information.

35

HID Electromagnetic
Ballasts

3x4
3x4
3x4
3x4
F-Can
F-Can
3x4
3x4
3x4
4.25x5.75
F-Can
3x4
4.25x5.75
3x4
4.25x5.75
3x4
3x4
3x4
3x4
3x4
3x4
F-Can
3x4
3x4
F-Can
3x4
4.25x4.75
3x4
F-Can
F-Can
4.25x4.75
4.25x4.75
4.25x4.75
4.25x6.00
4.25x6.00
4.25x6.00
4.25x6.00
4.25x6.00
3.7x1.6x1.0 Side Lead
3.7x3.0x1.2 Side Lead
3.7x3.0x1.2 Side Lead
3.7x3.0x1.2 Side Lead
3.7x3.0x1.2 Side Lead
3.7x3.0x1.2 Side Lead
7.3x2.6x2.2 BE w/Studs
3.7x3.0x1.2 Side Lead
3.7x3.0x1.2 Side Lead
3.7x3.0x1.2 Side Lead
7.3x2.6x2.2 BE w/Studs
3.7x3.0x1.2 Side Lead
7.3x2.6x2.2 BE w/Studs
7.3x2.6x2.2 BE w/Studs
7.3x2.6x2.2 BE w/Studs
7.3x2.6x2.2 BE w/Studs
7.3x2.6x2.2 BE w/Studs
7.3x2.6x2.2 BE w/Studs
7.3x2.6x2.2 BE w/Studs
3x4
3x4
3x4
3x4

Use with ANSI
Lamp Types Wattage

HID Electronic
Ballasts

HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
eHID
CWA
CWA
CWA
CWA
eHID
eHID Dim
eHID
eHID Dim
CWA
CWA
eHID
eHID Dim
CWA
CWA
eHID
eHID Dim
eHID
eHID Dim
CWA
CWA
CWA

Lamp
Type

Compact Fluorescent
Ballasts

GEM50MLTLC3D-5
GEM50MLTLC3D-5
GEM7048TLC3D-5
GEM70MLTLC3D-5
11210277CTC000C
11210506CTC000C
GEM7048TLC3D-5
GEM70MLTLC3D-5
GEM10048TLC3D-5
GEM100MLTLC3D-5
11210239CTC000I
GEM10048TLC3D-5
GEM100MLTLC3D-5
GEM10048TLC3D-5
GEM100MLTLC3D-5
GEM15048TLC3D-5
GEM150MLTLC3D-5
GEM15048TLC3D-5
GEM150MLTLC3D-5
GEM15048TLC3D-5
GEM150MLTLC3D-5
1110245SCTC000I
GEM175ML5AC3-5
GEM175MLTAC3-5
1110246CTC000C
GEM250ML5AC3-5
GEM250ML5AC4-5
GEM250MLTAC3-5
1110-247SC-TC
1111-247SCTC000I
GEM40048TAC4-5
GEM400ML5AA4-5
GEM400MLTAA4-5
GEM100048TAC5-5
GEM1000ML5AC5-5
GEM1000MLTAC5-5
GEM150048TAC5-5
GEM1500MLTAC5-5
GEMH20-MLF-120
GEMH39-MSF-120
GEMH50-MSF-120
GEMH50-MSF-120
GEMH50-MSF-120
GEMH70-MSF-120
GEMH70-SLJ-MV
GEMH70-MSF-120
GEMH70-MSF-120
GEMH70-MSF-120
GEMH70-SLJ-MV
GEMH70-MSF-120
GEMH70-SLJ-MV
GEMH100-SLJ-MV
GEMH100-SLJ-MV
GEMH100-SLJ-MV
GEMH150-SLJ-MV
GEMH150-SLJ-MV
GEMH150-SLJ-MV
GEP17548TAC3-5
GEP175MLTAC3-5
GEP17548TAC3-5
GEP175MLTAC3-5
GE-MH-250-400-MA
GEMH250-400MV50
GE-MH-250-400-MA
GEMH250-400MV50
GEP25048TAC4-5
GEP250MLTAC4-5
GE-MH-250-400-MA
GEMH250-400MV50
GEP25048TAC4-5
GEP250MLTAC4-5
GE-MH-250-400-MA
GEMH250-400MV50
GE-MH-250-400-MA
GEMH250-400MV50
GEP32048TAC4-5
GEP320MLTAC4-5
GEP320TRIAC4-5

Prod Code
Page No

Sign
Ballasts

34

86824
86824
86839
86847
86576
86578
86839
86847
86667
86675
86574
86667
86675
86667
86675
86711
86718
86711
86718
86711
86718
86563
87210
86741
86564
87211
87212
86765
42670
80728
86803
72300
72149
86650
87213
86655
86693
86698
87490
87501
87516
87516
87516
87531
87546
87531
87531
87531
87546
87531
87546
87561
87561
87561
87576
87576
87576
86876
86885
86876
86885
29377
89646
29377
89646
86926
86935
29377
89646
86926
86935
29377
89646
29377
89646
86952
86959
86968

Ignitor

T12
Fluorescent Ballasts

Pulse
Start

50
50
70
70
70
70
70
70
100
100
100
100
100
100
100
150
150
150
150
150
150
175
175
175
250
250
250
250
400
400
400
400
400
1000
1000
1000
1500
1500
20
39
50
50
50
70
70
70
70
70
70
70
70
100
100
100
150
150
150
175
175
175
175
250
250
250
250
250
250
250
250
250
250
320
320
320
320
320
320
320

Cap.

T5
Fluorescent Ballasts

Metal
Halide

M110
M148
M143
M143
M85
M98
M98
M98
M140
M140
M90
M90
M90
M92
M92
M102
M102
M107
M107
M142
M142
M57
M57
M57
M58
M58
M58
M58
M59
M59
M59
M59
M59
M47
M47
M47
M48
M48
M156
M130
C148
M110
M148
C143
C143
M139
M139
M143
M143
M98
M98
C140
M140
M90
C142
M102
M142
M137
M137
M152
M152
CMH250
CMH250
M138
M138
M138
M138
M153
M153
M153
M153
CMH320
CMH320
M132
M132
M132
M132
M132

Voltage

T8
Fluorescent Ballasts

High Intensity Discharge (HID) Lamps

Frame Size

Quick Reference
Guides

gelighting.com

GE Fluorescent Ballast Types

GE introduced the first fluorescent ballast more than 60 years ago. Today we are providing
high-frequency electronic ballasts for almost every fluorescent application.

UltraMax®
A family of high-efficiency GE T8 instant-start electronic linear
fluorescent ballasts designed to optimize GE’s T8 Ultra lamps for
optimal system energy savings. UltraMax® ballasts have a low lamp
current crest factor and virtually “read” and adapt to incoming voltage
from 108V to 305V. Other features include UL Type CC Anti-Arc Rating
and anti-striation control to eliminate lamp striations and spiraling.
These ballasts are offered in ballast factors: low wattage (.77), normal
light (.87), normal-high (N+) (1.0) and high (>1.15).
ProLine®
Offered in dedicated or multi-volt (120-277V), these high-performance
T8 instant-start ballasts also meet minimum efficiency requirements
as established with the NEMA Premium® ballast program. These
ballasts are offered in ballast factors: low wattage (.77), normal light
(.87), and high (>1.15).

Ballast Life
GE electronic ballasts are designed and manufactured to an
average life expectancy of 60,000 hours of operation at maximum
rated case temperatures. As a rule of thumb, ballast life is doubled
for every 10C reduction in ballast case temperature. However
there are other variables such as transients, voltage sags and
swells, ambient temperature, etc., which affect ballast life as well.
Instant Start vs. Rapid Start Sockets
When using programmed start or dimming ballasts in fixtures,
sockets must be 2-pin rapid start type. Fixtures with T8 instant
start ballasts must use jumpered rapid start sockets or shunted
lamp holders (internal to the lamp holder) that bridge the lamp
bi-pins together into one contact on each side of the lamp. If
retrofitting from a instant start ballast fixture with shunted
sockets to a dimming or programmed start ballast, rapid start
type sockets must be used to properly start lamps and maintain
rated lamp life.

Programmed Start
Programmed Start electronic ballasts have a lamp starting method
that preheats lamp filaments while not allowing the lamp to ignite
and then applies an open circuit voltage (OCV) to start the lamp. Use
Programmed Start ballasts to ensure long lamp life when turning
lamps on and off more than five times in a day or in conjunction with
any automatic light control or sensor. This type of starting circuit
keeps lamp-end blackening to a minimum and improves lamp
life performance, especially in applications where the lamps are
frequently switched on and off.

Compact Fluorescent
Ballasts

GE Ballast Electronic nomenclature

G E - 2

3 2 - M V P S - N - 4 2 T

See page 195 for warranty information.

See page 195 for warranty information.

Ultra-Hi Efficiency
84T, 42T, T = 840, 420 qty
OEM pallet packs
A, D, E, F = Can sizes
BES = Bottom exit with studs
SE = Dual – side & bottom exit
3W = 3 way mounting kit

37

HID Electromagnetic
Ballasts

IS = Instant Start,
Lamp Watts
standard if not shown
(Primary Lamp)
RS = Rapid Start
T8 = 32-four foot,
PS = Program Start
59-eight
foot
Maximum
T12 = 40-four foot,
number
60-eight foot
of lamps
Ballast Factor
supported
120 = 120 volt
L =Low Power for
by this ballast 277 = 277 volt
MAX savings
– 1, 2, 3, 4, 6
MAX or MV =
N = Normal for
120 – 277V
New Fixtures
H = High Power,
Hi-Light, Hi-Bay
GE Ballast
GE = LFL
GEC = CFL

36

HID Electronic
Ballasts

UltraStart®
UltraStart® is a family of high-efficiency GE Programmed Start
electronic linear fluorescent ballasts that also exceed NEMA Premium®
ballast efficiency requirements but are designed to optimize GE’s
T8 Ultra lamps in frequently switched applications. Instant start
ballasts provide 7,000-13,000 starts before 50% lamp failure.
UltraStart® provides greater than 100,000 starts before 50% lamp
failure. UltraStart® ballasts have the same energy savings and
convenience of instant start ballasts but with the long lamp life of
a programmed start ballast. These ballasts are offered in ballast
factors: programmed start x-low wattage (XL) (.60), low wattage (.71),
normal light (.87), and high (>1.15).

Sign
Ballasts

GE revolutionizes lighting again with breakthrough technology. Our patented UltraMax®
instant-start and UltraStart® programmed start electronic ballasts transform the power of
light into efficiency and savings from store shelves to the installation site. The foundation of
the “Ultra” family of ballasts starts with its high efficiency ratings. High efficiency ballasts
are a minimum of 90% efficiency with some ballasts nearly 95% efficient which means the
ballast only consumes 5-10% of the total system power. These high efficiency ballasts exceed
minimum high efficiency standards as established by almost all energy advocate groups,
utility rebate programs and the NEMA Premium® ballast program. The ballasts are marked with
the Ultra brand as well as the NEMA Premium® ballast mark. These ballasts have multi-voltage
control (MVC), which automatically adjusts to handle voltage from 120V through 277V. That
cuts the ballast models you need to stock from 40 down to 13, which can dramatically reduce
inventory carrying costs. UltraMax® ballasts have ArcGuard Protection, too, with a UL Type
CC Anti-Arc Rating. Plus, they’re ultra-lamp-friendly, with a low lamp current crest factor of
1.4 for optimal lamp performance. Both UltraMax® and UltraStart® have anti-striation control
for better light quality with no lamp striations (spiraling). And the small, low-profile design of
these ballasts makes retrofits effortless at the job site. Also unique to our programmed start
UltraStart® ballasts is parallel lamp operation which ensures if one lamp fails the others remain
on, and quick starting times of less than 700 milliseconds which is necessary in avoiding delays
with automatic sensors.

Date Codes
GE electronic ballast manufacturing date codes are located on
the upper right-hand corner of the label. The code lists the month,
year and day of manufacture. A typical code is C06-073, where
the month is listed as A (January), B (February), C (March) (as in this
code) followed by the year 06 (2006) and the date of manufacture
073 (the 73rd day of 2006).

T12
Fluorescent Ballasts

With our UltraMax® and UltraStart® ballasts, we are bringing you
the future in ballast performance.

The most common fluorescent ballast is the instant start and is used
typically in long 3 to 10-hour lamp cycle applications. These ballasts
are energy efficient and can deliver up to 20% to greater than 40%
energy savings when installed with energy-efficient lamps in building
retrofits. These ballasts deliver >550 open circuit volts when starting
lamps and operate lamps at high frequencies which offers flicker-free
operation and better lamp efficiencies. The ballasts are significantly
quieter than conventional magnetic ballasts and are backed by
GE’s ultra system 5-year ballast limited warranty and extended
lamp warranties.

T5
Fluorescent Ballasts

A comprehensive range of solutions…from GE, the name you trust.

Ballast Date Codes
T8
Fluorescent Ballasts

Understanding T8
Fluorescent Ballasts

Electronic Instant Start

Quick Reference
Guides

gelighting.com

UltraMax® Instant Start Multi-Voltage High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
UltraMax® Instant Start Multi-Voltage High-Efficiency
®

General characteristics

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Low
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Wiring diagram – LFL 1A – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
72258

Pallet Pack

DIY Pack

IP Pack

System Watts
25
25
24
24
22
22
21
21
21
21
15
15
12
12

Safety and performance

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
0.87 in (22.00 mm)
0.3 in (7.92 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
34 in (864 mm)
41 in (1041 mm)
25 in (635 mm)

UL Type HL

Ballast Efficacy Factor
3.08
3.08
3.20
3.20
3.50
3.50

FCC – CLASS A Non-Consumer

Electrical characteristics
Supply Current Frequency

®

1 – F32T8 120 to 277 “N” .87 BF UltraMax

General characteristics

Order information
10 Pack
49775

UL Class P

Power Factor% (>=)
99
94
99
93
99
93
99
92
99
92
99
88
86
99

cUL Listed

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Type CC

UL Listed

THD% (<=)
10
10
10
10
10
10
10
20
10
20
12
25
13
27

Min. Starting Temp (°F/°C)
-22 / -30
-22 / -30
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

• Energy-saving high-efficiency instant-start electronic ballast (>90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Lamp frequency >70kHz

Order information
DIY Pack
72260 (replaces 23939)

IP Pack

UL Type 1 Outdoor

NRCan

UL Type HL

Ballast Efficacy Factor
1.55
1.57
2.80
2.87
1.61
1.64
2.94
2.94
1.74
1.76
3.19
3.19

FCC – CLASS A Non-Consumer

Power Factor% (>=)
99
98
96
99
99
98
99
96
99
97
99
96

RoHS Compliant

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Class P

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10

UL Type CC

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16

UL Listed

72262 – GE232MAX-L/ULTRA (replaces 49707)
UltraMax® Instant Start Multi-Voltage High-Efficiency
2 or 1 – F32T8 120 to 277 “L” .77 BF UltraMax®

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
0.87 in (22.00 mm)
0.3 in (7.92 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
41 in (1041 mm)
25 in (635 mm)
34 in (864 mm)

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Low
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Wiring diagram LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
White
Red

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
72262

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Lamp frequency >70kHz

Pallet Pack
72256 (replaces 47546)

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
0.87 in (22.00 mm)
0.3 in (7.92 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
34 in (864 mm)
25 in (635 mm)
41 in (1041 mm)

Specifications by lamp and wattage
Nom. Line Current
0.24 A
0.11 A
0.23 A
0.10 A
0.22 A
0.10 A
0.22 A
0.10 A
0.09 A
0.19 A
0.14 A
0.07 A
0.12 A
0.06 A

UL Type 1 Outdoor

UL Type CC

System Ballast Factor
0.87
0.87
0.87
0.87
0.87
0.87

UL Type HL

Ballast Efficacy Factor
3.10
3.10
3.22
3.22
3.48
3.48

FCC – CLASS A Non-Consumer

Power Factor% (>=)
99
98
99
98
99
98
99
94
93
99
99
90
99
88

UL Class P

cUL Listed

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Listed

THD% (<=)
10
10
10
10
10
10
10
17
18
10
10
22
11
25

Min. Starting Temp (°F/°C)
-22 / -30
-22 / -30
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

Lamp

# of Lamps
Line Volts
System Watts
2
120
51
2
277
50
1
277
29
F32T8
1
120
28
2
120
47
2
277
47
1
277
27
F32T8/WM
1
120
26
2
120
43
2
277
43
1
277
25
F28T8
1
120
24
2
120
42
2
277
42
1
120
24
F25T12
1
277
24
Other compatible lamps: F25T8, FE15T8, F17T8, F32T8/25W

Nom. Line Current
0.42 A
0.19 A
0.11 A
0.24 A
0.40 A
0.18 A
0.11 A
0.22 A
0.38 A
0.18 A
0.10 A
0.21 A
0.36 A
0.16 A
0.21 A
0.10 A

System Ballast Factor
0.78
0.78
0.77
0.77
0.77
0.77
0.77
0.77
0.74
0.74
0.77
0.77

Ballast Efficacy Factor
1.53
1.56
2.65
2.75
1.64
1.63
2.85
2.96
1.72
1.72
3.08
3.20

Power Factor% (>=)
99
97
93
99
99
97
93
99
99
97
92
99
99
96
99
91

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
19
11
20

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

Safety and performance
See page 195 for warranty information.

See page 195 for warranty information.

UL Type 1 Outdoor

NRCan

UL Type CC

RoHS Compliant

UL Type HL

FCC – CLASS A Non-Consumer

UL Class P

cUL Listed

UL Listed

39

HID Electromagnetic
Ballasts

38

Safety and performance

System Ballast Factor
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15

HID Electronic
Ballasts

Safety and performance

# of Lamps
Line Volts
System Watts
Nom. Line Current
2
120
74
0.62 A
2
277
73
0.27 A
1
277
41
0.16 A
F32T8
1
120
40
0.36 A
2
120
71
0.59 A
2
277
70
0.26 A
1
120
39
0.34 A
F32T8/WM
1
277
39
0.15 A
2
120
66
0.58 A
2
277
65
0.26 A
1
120
36
0.32 A
F28T8
1
277
36
0.15 A
Other compatible lamps: FE15T8, F40T8, F25T8, F25T12, F17T8, F32T8/25W

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
System Watts
28
28
27
27
25
25
25
25
24
23
17
17
14
14

IP Pack

Compact Fluorescent
Ballasts

50 Hz/60 Hz

# of Lamps
Line Volts
1
120
F32T8
1
277
1
120
F32T8/WM
1
277
1
120
F28T8
1
277
1
120
F25T12
1
277
1
277
F25T8
1
120
1
120
F17T8
1
277
1
120
FE15T8
1
277
Other compatible lamps: F32T8/25W

DIY Pack

General characteristics

Wiring diagram – LFL 1A – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

Electrical characteristics

Lamp

Pallet Pack
47548

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
25 in (635 mm)
34 in (864 mm)
41 in (1041 mm)

RoHS Compliant

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Pallet Pack

50 Hz/60 Hz

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)

Sign
Ballasts

UltraMax® Instant Start Multi-Voltage High-Efficiency

10 Pack
72259

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
White
Blue
Red

Specifications by lamp and wattage
System Ballast Factor
0.77
0.77
0.77
0.77
0.77
0.77

72259 – GE-132MAX-N/ULTRA (replaces 49771)

Supply Current Frequency

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Lamp
Nom. Line Current
0.22 A
0.10 A
0.21 A
0.09 A
0.20 A
0.09 A
0.18 A
0.08 A
0.19 A
0.09 A
0.13 A
0.07 A
0.10 A
0.05 A

UL Type 1 Outdoor

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

General characteristics

T12
Fluorescent Ballasts

# of Lamps
Line Volts
1
120
F32T8
1
277
1
120
F32T8/WM
1
277
1
120
F28T8
1
277
1
120
F25T8
1
277
1
120
F25T12
1
277
1
120
F17T8
1
277
1
120
FE15T8
1
277
Other compatible lamps: F32T8/25W

2 or 1 – F32T8 120 to 277 “H” 1.15 BF UltraMax®
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

UltraMax® Instant Start Multi-Voltage High-Efficiency

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

49775 – GE232MAX-H/ULTRA

T8
Fluorescent Ballasts

• Energy-saving high-efficiency instant-start electronic ballast (>90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Lamp frequency >70kHz

72258 – GE132MAX-L/ULTRA (replaces 49706)
1 – F32T8 120 to 277 “L” .77 BF UltraMax

UltraMax® Instant Start Multi-Voltage High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps

Quick Reference
Guides

gelighting.com

UltraMax® Instant Start Multi-Voltage High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
72266 – GE232MAX-N/ULTRA (replaces 49772)
®

2 or 1 – F32T8 120 to 277 “N” .87 BF UltraMax

General characteristics

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
10 Pack
72266

Pallet Pack
72267 (replaces 31052)

DIY Pack
72268 (replaces 23940)

IP Pack

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
0.87 in (22.00 mm)
0.3 in (7.92 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
41 in (1041 mm)
25 in (635 mm)
25 in (635 mm)
34 in (864 mm)

Safety and performance

UL Type 1 Outdoor

RoHS Compliant

System Ballast Factor
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87

UL Type HL

Ballast Efficacy Factor
1.61
1.64
2.80
2.80
1.64
1.67
3.00
3.00
1.77
1.81
3.22
3.22

Electrical characteristics

®

General characteristics

Order information
10 Pack
71714

UL Class P

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
16
10
22

UL Type CC

NRCan

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations

Dimensions

50 Hz/60 Hz

Order information
Pallet Pack

DIY Pack

IP Pack

Wiring diagram LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White

IP Pack

RoHS Compliant

UL Type CC

Ballast Efficacy Factor
1.59
1.61
2.77
2.81
1.67
1.68
2.91
2.96
1.79
1.75
3.11
3.02
1.74
1.75
3.11
3.05

UL Type HL

NRCan

Power Factor% (>=)
99
98
96
99
99
98
96
99
99
98
99
96
99
98
99
96

UL Type 1 Outdoor

UL Type HL

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
34 in (864 mm)
41 in (1041 mm)
25 in (635 mm)

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
15
10
18

71717 – GE332MAX-L/ULTRA (replaces 49708)
UltraMax® Instant Start Multi-Voltage High-Efficiency
3 or 2 – F32T8 120 to 277 “L” .77 BF UltraMax®

UL Class P

cUL Listed

50 Hz/60 Hz

Order information

UL Listed

See page 195 for warranty information.

cUL Listed

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Type CC

UL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
13
10
17

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Lamp frequency >70 kHz
• UL 55C Ambient Temperature rating
Wiring diagram LFL 1C – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

Electrical characteristics

10 Pack
71717

UL Class P

Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Low
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Supply Current Frequency

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

Ballast Efficacy Factor
1.06
1.08
1.49
1.51
1.08
1.10
1.57
1.57
1.17
1.19
1.69
1.71

FCC – CLASS A Non-Consumer

General characteristics

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

FCC – CLASS A Non-Consumer

Safety and performance

System Ballast Factor
1.18
1.18
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15

Pallet Pack
71718 (replaces 31055)

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
41 in (1041 mm)
25 in (635 mm)
34 in (864 mm)

Specifications by lamp and wattage
Lamp

# of Lamps
Line Volts
System Watts
3
120
73
3
277
72
2
120
53
F32T8
2
277
53
3
120
69
3
277
68
2
120
49
F32T8/WM
2
277
49
3
120
65
3
277
65
2
120
46
F28T8
2
277
46
3
120
63
3
127
63
2
120
63
F25T12
2
277
63
Other compatible lamps: FE15T8, F25T8, F17T8, F32T8/25W

Safety and performance
See page 195 for warranty information.

Nom. Line Current
0.63 A
0.27 A
0.45 A
0.20 A
0.60 A
0.26 A
0.42 A
0.19 A
0.57 A
0.25 A
0.40 A
0.18 A
0.53 A
0.24 A
0.56 A
0.25 A

UL Type 1 Outdoor

UL Type CC

System Ballast Factor
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77

UL Type HL

Ballast Efficacy Factor
1.05
1.06
1.45
1.45
1.11
1.13
1.57
1.57
1.18
1.18
1.67
1.67

FCC – CLASS A Non-Consumer

Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
96
99
97
99
97

UL Class P

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

cUL Listed

UL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
13
18
10

RoHS Compliant

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

41

HID Electromagnetic
Ballasts

UL Type 1 Outdoor

System Ballast Factor
1.00
1.00
0.96
0.96
1.00
1.00
0.97
0.97
1.00
1.00
0.98
0.97
0.97
0.97
0.95
0.95

# of Lamps
Line Volts
System Watts
Nom. Line Current
3
120
111
0.92 A
3
277
109
0.40 A
2
120
77
0.68 A
F32T8
2
277
76
0.30 A
3
120
106
0.89 A
3
277
104
0.39 A
2
120
73
0.65 A
F32T8/WM
2
277
73
0.28 A
3
120
98
0.86 A
3
277
96
0.37 A
2
120
68
0.59 A
F28T8
2
277
67
0.26 A
3
120
98
0.86 A
3
277
96
0.37 A
2
120
68
0.60 A
F25T12
2
277
68
0.26 A
Other compatible lamps: FE15T8, F40T8, F25T8, F17T8, F32T8/25W

HID Electronic
Ballasts

# of Lamps
Line Volts
System Watts
Nom. Line Current
2
120
63
0.53 A
2
277
62
0.23 A
1
277
35
0.13 A
F32T8
1
120
34
0.29 A
2
120
60
0.50 A
2
277
60
0.22 A
1
277
33
0.13 A
F32T8/WM
1
120
33
0.28 A
2
120
58
0.48 A
2
277
57
0.21 A
1
120
32
0.26 A
F28T8
1
277
32
0.12 A
2
120
56
0.47 A
2
277
56
0.21 A
1
120
31
0.26 A
F25T12
1
277
31
0.12 A
Other compatible lamps: FE15T8, F25T8, F17T8, F40T8, F32T8/25W

Safety and performance

DIY Pack

Lamp

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

40

Pallet Pack
71715 (replaces 47549)

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
34 in (864 mm)
41 in (1041 mm)
25 in (635 mm)
25 in (635 mm)

Compact Fluorescent
Ballasts

Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Electrical characteristics

10 Pack
71421

50 Hz/60 Hz

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)

Sign
Ballasts

2 or 1 – F32T8 120 to 277 “N+” 1.0 BF UltraMax

Power Factor% (>=)
99
96
99
94
99
96
99
94
99
96
99
93
99
97
99
93

FCC – CLASS A Non-Consumer

UltraMax® Instant Start Multi-Voltage High-Efficiency

Supply Current Frequency

Wiring diagram – LFL 1C – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
Red
White
Black

Specifications by lamp and wattage
Nom. Line Current
0.47 A
0.21 A
0.26 A
0.12 A
0.45 A
0.20 A
0.25 A
0.12 A
0.42 A
0.19 A
0.24 A
0.11 A
0.41 A
0.18 A
0.24 A
0.11 A

71421 – GE232MAX-N+

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Supply Current Frequency

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Lamp frequency >70 kHz
• UL 55C Ambient Temperature rating

T12
Fluorescent Ballasts

# of Lamps
Line Volts
System Watts
2
120
54
2
277
53
1
120
31
F32T8
1
277
31
2
120
53
2
277
52
1
120
29
F32T8/WM
1
277
29
2
120
49
2
277
48
1
120
27
F28T8
1
277
27
2
120
48
2
277
48
1
120
27
F25T12
1
277
27
Other compatible lamps: FE15T8, F25T8, F17T8, F32T8/25W

3 or 2 – F32T8 120 to 277 “H” 1.18 BF UltraMax®

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

UltraMax® Instant Start Multi-Voltage High-Efficiency
General characteristics

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Black
Blue

Electrical characteristics
Supply Current Frequency

71714 – GE332MAX-H/ULTRA (replaces 49776)

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Lamp frequency >70kHz

T8
Fluorescent Ballasts

UltraMax® Instant Start Multi-Voltage High-Efficiency

UltraMax® Instant Start Multi-Voltage High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps

Quick Reference
Guides

gelighting.com

UltraMax® Instant Start Multi-Voltage High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
71719 – GE332MAX-N/ULTRA (replaces 49773)
®

3 or 2 – F32T8 120 to 277 “N” .87 BF UltraMax

General characteristics

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
Pallet Pack
71721 (replaces 31053)

DIY Pack
71722 (replaces 23941)

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
25 in (635 mm)
41 in (1041 mm)
34 in (864 mm)

Safety and performance

UL Type HL

System Ballast Factor
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87

Ballast Efficacy Factor
1.06
1.08
1.50
1.50
1.11
1.12
1.58
1.58
1.20
1.22
1.70
1.70

FCC – CLASS A Non-Consumer

Electrical characteristics

®

UltraMax Instant Start Multi-Voltage High-Efficiency
3 or 2 – F32T8 120 to 277 “N+” 1.0 BF UltraMax

®

General characteristics

Order information
10 Pack
71723

UL Class P

Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97

cUL Listed

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Type CC

UL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
13
10
16

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

Order information
DIY Pack

IP Pack

Wiring diagram LFL 1C – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
White and Black
Red
Blue

RoHS Compliant

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
1.18
1.18
1.15
1.15
1.15
1.15
1.15
1.15

Ballast Efficacy Factor
0.80
0.81
1.00
1.01
0.79
0.81
1.04
1.05

1.15
1.15
1.15
1.15

0.86
0.87
1.13
1.15

FCC – CLASS A Non-Consumer

71725 – GE432MAX-L/ULTRA (replaces 49709)
UltraMax® Instant Start Multi-Voltage High-Efficiency
4 or 3 – F32T8 120 to 277 “L” .77 BF UltraMax®

General characteristics
9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
34 in (864 mm)
25 in (635 mm)
41 in (1041 mm)
34 in (864 mm)

cUL Listed

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Type CC

UL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
14
10
17
10
10
10
10

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16

RoHS Compliant

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Lamp frequency >70 kHz
• UL 55C Ambient Temperature rating

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Low
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Wiring diagram LFL 1D – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
Black
White
Yellow

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
71725

UL Class P

Power Factor% (>=)
99
98
99
97
99
97
99
97
99
97
99
97
99
98
99
97

Pallet Pack
71726 (replaces 47547)

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
34 in (864 mm)
25 in (635 mm)
25 in (635 mm)
41 in (1041 mm)

Specifications by lamp and wattage
Nom. Line Current
0.77 A
0.33 A
0.54 A
0.24 A
0.73 A
0.32 A
0.52 A
0.23 A
0.69 A
0.30 A
0.50 A
0.22 A
0.67 A
0.29 A
0.48 A
0.22 A
UL Type 1 Outdoor

System Ballast Factor
1.00
1.00
0.94
0.94
1.00
1.00
0.95
0.95
1.00
1.00
0.96
0.95
0.93
0.93
0.93
0.93
UL Type CC

Ballast Efficacy Factor
1.09
1.11
1.47
1.48
1.15
1.17
1.55
1.56
1.21
1.23
1.62
1.62
1.16
1.18
1.63
1.65
UL Type HL

Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
UL Class P

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
16
10
19

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

See page 195 for warranty information.

Lamp

# of Lamps
Line Volts
System Watts
4
120
97
4
277
96
3
120
78
F32T8
3
277
77
4
120
92
4
277
91
3
120
72
F32T8/WM
3
277
72
4
120
87
4
277
86
3
120
67
F28T8
3
277
67
4
120
84
4
277
83
3
120
65
F25T12
3
277
65
Other compatible lamps: FE15T8, F25T8, F17T8, F32T8/25W

Safety and performance
See page 195 for warranty information.

Nom. Line Current
0.84 A
0.37 A
0.65 A
0.29 A
0.80 A
0.36 A
0.61 A
0.27 A
0.77 A
0.34 A
0.59 A
0.26 A
0.71 A
0.31 A
0.58 A
0.25 A

UL Type 1 Outdoor

UL Type CC

System Ballast Factor
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77

UL Type HL

Ballast Efficacy Factor
0.79
0.80
0.98
1.00
0.83
0.84
1.06
1.06
0.88
0.89
1.14
1.14

FCC – CLASS A Non-Consumer

Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
99
97
99
97

RoHS Compliant

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Class P

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
15
10
18

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

43

HID Electromagnetic
Ballasts

Safety and performance
42

# of Lamps
Line Volts
System Watts
Nom. Line Current
4
120
148
1.36 A
4
277
145
0.59 A
3
120
115
1.04 A
F32T8
3
277
113
0.45 A
4
120
145
1.31 A
4
277
141
0.56 A
3
120
110
0.99 A
F32T8/WM
3
277
109
0.43 A
4
120
134
1.21 A
4
277
132
0.52 A
3
120
102
0.92 A
F25T12
3
277
101
0.40 A
4
120
133
1.20 A
4
277
131
0.52 A
3
120
101
0.91 A
F28T8
3
277
100
0.40 A
Other compatible lamps: FE15T8, F40T8, F25T8, F17T8, F32T8/25W

HID Electronic
Ballasts

# of Lamps
Line Volts
System Watts
3
120
91
3
277
90
2
120
64
F32T8
2
277
64
3
120
87
3
277
86
2
120
61
F32T8/WM
2
277
61
3
120
83
3
277
82
2
120
59
F28T8
2
277
59
3
120
80
3
277
79
2
120
57
F25T12
2
277
57
Other compatible lamps: F25T8, F15T8, F40T8, F17T8, F32T8/25W

IP Pack

Lamp

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

DIY Pack

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
34 in (864 mm)
34 in (864 mm)
41 in (1041 mm)

Compact Fluorescent
Ballasts

50 Hz/60 Hz

Pallet Pack

Pallet Pack
71724 (replaces 47550)

Safety and performance

RoHS Compliant

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
221°F (105°C)
70°C (158°F)
Normal – High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Electrical characteristics

10 Pack
71422

50 Hz/60 Hz

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)

Sign
Ballasts

71422 – GE332MAX-N+

Supply Current Frequency

Wiring diagram – LFL 1D – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Red
Blue
Yellow

Specifications by lamp and wattage
Nom. Line Current
0.70 A
0.30 A
0.49 A
0.22 A
0.66 A
0.29 A
0.46 A
0.21 A
0.63 A
0.28 A
0.44 A
0.20 A
0.61 A
0.27 A
0.44 A
0.19 A

UL Type 1 Outdoor

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Supply Current Frequency

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Lamp frequency >70 kHz
• UL 55C Ambient Temperature rating

T12
Fluorescent Ballasts

# of Lamps
Line Volts
System Watts
3
120
82
3
277
80
2
120
58
F32T8
2
277
58
3
120
78
3
277
77
2
120
55
F32T8/WM
2
277
55
3
120
72
3
277
71
2
120
51
F28T8
2
277
51
3
120
72
3
277
71
2
120
49
F25T12
2
277
49
Other compatible lamps: FE15T8, F25T8, F17T8, F32T8/25W

4 or 3 – F32T8 120 to 277 “H” 1.18 BF UltraMax®

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

UltraMax® Instant Start Multi-Voltage High-Efficiency
General characteristics

Wiring diagram – LFL 1C – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
White
Red
Blue

Electrical characteristics
Supply Current Frequency

71723 – GE432MAX-H/ULTRA (replaces 49777)

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

10 Pack
71719

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Lamp frequency >70 kHz
• UL 55C Ambient Temperature rating

T8
Fluorescent Ballasts

UltraMax® Instant Start Multi-Voltage High-Efficiency

UltraMax® Instant Start Multi-Voltage High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps

Quick Reference
Guides

gelighting.com

UltraMax® Instant Start Multi-Voltage High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
71727 – GE432MAX-N/ULTRA (replaces 49774)
®

4 or 3 – F32T8 120 to 277 “N” .87 BF UltraMax

General characteristics

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
10 Pack
71727

Pallet Pack
71729 (replaces 31054)

DIY Pack
71730 (replaces 23942)

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
34 in (864 mm)
25 in (635 mm)
41 in (1041 mm)
25 in (635 mm)

Safety and performance

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87

Ballast Efficacy Factor
0.79
0.81
1.02
1.03
0.82
0.84
1.07
1.08
0.88
0.90
1.14
1.16

FCC – CLASS A Non-Consumer

Electrical characteristics
Supply Current Frequency

4 or 3 – F32T8 120 to 277 “N+” 1.0 BF UltraMax

®

General characteristics

Order information

UL Class P

Power Factor% (>=)
99
98
99
99
99
98
99
97
99
98
99
97
99
98
99
97

cUL Listed

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Type CC

UL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
14
10
17

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

DIY Pack

IP Pack

F96T8
F96T8/WM
F40T8
F96T8/WMP

# of Lamps
1
1
1
1
1
1
1
1

Line Volts
120
277
120
277
120
277
120
277

System Watts
54
53
51
51
38
38

Safety and performance

Nom. Line Current
0.46 A
0.21 A
0.43 A
0.20 A
0.32 A
0.15 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.87
0.87
0.87
0.87

Ballast Efficacy Factor
1.61
1.64
1.70
1.70

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
95
99
95
99
95
99
95
cUL Listed

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Type CC

UL Listed

THD% (<=)
10
15
10
15
10
18
10
15

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

49767 – GE259MAX-N/ULTRA
UltraMax® Instant Start Multi-Voltage High-Efficiency
2 or 1 – F96T8 120 to 277 “N” .87 BF UltraMax®

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)
8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.16 lbs
Side
18 ft
18 AWG
Length (± 1 in)
41 in (1041 mm)
34 in (864 mm)
25 in (635 mm)
25 in (635 mm)

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Wiring diagram LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
White
Red

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
49767

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• UL Type CC Rating provides protection against arcing with F96T8 lamps only

Pallet Pack

DIY Pack
23954

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
58 in (1473 mm)
25 in (635 mm)
66 in (1676 mm)

UL Type HL

Ballast Efficacy Factor
0.81
0.83
1.02
1.00
0.84
0.86
1.07
1.08
0.88
1.04
1.12
1.13
0.87
0.89
1.13
1.13

FCC – CLASS A Non-Consumer

Power Factor% (>=)
99
98
97
99
99
98
99
97
99
97
99
96
99
97
99
96

UL Class P

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

cUL Listed

UL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
16
10
19

Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

Lamp

# of Lamps
Line Volts
2
120
2
277
1
120
F96T8
1
277
2
120
2
277
1
120
F96T8/WM
1
277
2
120
2
277
1
120
F96T8/WMP
1
277
2
120
2
277
1
120
F72T8
1
277
Other compatible lamps: F40T8

System Watts
107
105
62
62
102
100
59
59
85
84
59
59
79
78
44
44

RoHS Compliant

Safety and performance

See page 195 for warranty information.

See page 195 for warranty information.

Nom. Line Current
0.91 A
0.40 A
0.53 A
0.24 A
0.87 A
0.38 A
0.50 A
0.23 A
0.78 A
0.32 A
0.50 A
0.23 A
0.72 A
0.29 A
0.39 A
0.17 A

UL Type 1 Outdoor

UL Type CC

System Ballast Factor
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.89
0.89
0.87
0.87

UL Type HL

Ballast Efficacy Factor
0.81
0.82
1.40
1.40
0.85
0.87
1.47
1.47
1.04
1.05
1.47
1.47

FCC – CLASS A Non-Consumer

Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
0.99
0.98
0.99
0.96

UL Class P

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

cUL Listed

UL Listed

THD% (<=)
10
15
10
20
10
15
10
20
10
15
10
20
10
13
10
20

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

45

HID Electromagnetic
Ballasts

UL Type CC

System Ballast Factor
1.00
1.00
1.15
0.97
1.00
1.00
0.99
0.99
1.00
1.00
0.99
0.99
0.96
0.96
0.97
0.97

HID Electronic
Ballasts

Specifications by lamp and wattage

# of Lamps
Line Volts
System Watts
Nom. Line Current
4
120
124
1.03 A
4
277
121
0.45 A
3
277
113
0.45 A
F32T8
3
120
97
0.81 A
4
120
119
1.00 A
4
277
117
0.44 A
3
120
92
0.77 A
F32T8/WM
3
277
92
0.35 A
4
120
114
0.95 A
4
277
96
0.36 A
3
120
89
0.74 A
F28T8
3
277
88
0.33 A
4
120
110
0.92 A
4
277
108
0.40 A
3
120
86
0.72 A
F25T12
3
277
86
0.32 A
Other compatible lamps: FE15T8, F25T8, F40T8, F17T8, F32T8/25W
UL Type 1 Outdoor

Lamp

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

Safety and performance

IP Pack

Compact Fluorescent
Ballasts

Order information

44

DIY Pack

General characteristics

Wiring diagram LFL 1D – see example on page 72
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Yellow
Blue and Red
White and Black
Black

50 Hz/60 Hz

Pallet Pack

Pallet Pack

8.8 in (225.80 mm)
1.1 in (27.94 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
66 in (1676 mm)
25 in (635 mm)
58 in (1473 mm)

RoHS Compliant

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
221°F (105°C)
70°C (158°F)
Normal – High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

Electrical characteristics

10 Pack
71423

50 Hz/60 Hz

9.5 in (241.30 mm)
1.7 in (43.18mm)
1.18 in (30.00 mm)

Sign
Ballasts

UltraMax® Instant Start Multi-Voltage High-Efficiency

Supply Current Frequency

Wiring diagram – LFL 1A – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White
Red
Black
Blue

Specifications by lamp and wattage
Nom. Line Current
0.94 A
0.40 A
0.72 A
0.32 A
0.90 A
0.39 A
0.68 A
0.30 A
0.84 A
0.37 A
0.67 A
0.29 A
0.76 A
0.33 A
0.64 A
0.28 A

71423 – GE432MAX-N+

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected

10 Pack
49766

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations

T12
Fluorescent Ballasts

# of Lamps
Line Volts
System Watts
4
120
109
4
277
107
3
120
85
F32T8
3
277
84
4
120
105
4
277
103
3
120
81
F32T8/WM
3
277
80
4
120
98
4
277
96
3
120
76
F28T8
3
277
75
4
120
91
4
277
89
3
120
72
F25T8
3
277
71
Other compatible lamps: FE15T8, F25T12, F17T8, F32T8/25W

1 – F96T8 120 to 277 “N” .87 BF UltraMax®

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

UltraMax® Instant Start Multi-Voltage High-Efficiency
General characteristics

Wiring diagram – LFL 1D – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White
Yellow
Black

Electrical characteristics
Supply Current Frequency

49766 – GE159MAX-N/ULTRA

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Lamp frequency >70 kHz
• UL 55C Ambient Temperature rating

T8
Fluorescent Ballasts

UltraMax® Instant Start Multi-Voltage High-Efficiency

UltraMax® Instant Start Multi-Voltage High-Efficiency
T8 Instant Start Ballasts For 46 – 59W 4 ft – 8 ft Slimline Lamps

Quick Reference
Guides

gelighting.com

ProLine® T8 Multivolt 120V – 277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
ProLine® T8 Multivolt 120V – 277V
®

General characteristics

Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
10 Pack
72269

Pallet Pack
72270 (replaces 30268)

DIY Pack

IP Pack

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
0.87 in (22.00 mm)
0.3 in (7.92 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
48 in (1219 mm)
22 in (559 mm)
30 in (762 mm)
22 in (559 mm)

System Watts
29
28
29
29
27
27
25
25
19
18

Safety and performance

Electrical characteristics
50 Hz/60 Hz

Order information
10 Pack
72273

Pallet Pack
72274 (replaces 30308)

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.87
0.87
0.83
0.83
0.80
0.80
0.88
0.88
0.88
0.88

Ballast Efficacy Factor
3.00
3.11
2.88
2.87
3.01
3.01
3.54
3.52
4.68
4.78

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
95
99
95
99
94
99
94
91
99
cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
10
10
15
20
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

ProLine® T8 Multivolt 120V – 277V
2 or 1 – F32T8 120 to 277 “H” 1.18 BF Multivolt ProLine

®

General characteristics

Dimensions

Lamp

# of Lamps
Line Volts
System Watts
2
120
49.5
2
277
48.6
1
120
35.0
F32T8
1
277
35.0
2
120
48.0
2
277
47.0
1
120
31.0
F32T8/WM
1
277
31.0
2
120
44.0
2
277
43.0
1
120
29.0
F28T8
1
277
29.0
2
120
40.0
2
277
40.0
1
120
27.0
F25T8
1
277
27.0
Other compatible lamps: F40T8, F17T8, F32T8/25W

Order information
Pallet Pack
30275

DIY Pack

IP Pack

FCC – CLASS A Non-Consumer

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
48 in (1219 mm)
22 in (559 mm)
30 in (762 mm)
22 in (559 mm)

2 or 1 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine®

cUL Listed

UL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
18
10
21

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black

Electrical characteristics
50 Hz/60 Hz

Order information
10 Pack
72275

UL Class P

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

ProLine® T8 Multivolt 120V – 277V

Supply Current Frequency

Power Factor% (>=)
99
96
99
94
99
96
99
94
99
96
99
94
99
95
99
93

Pallet Pack
72276 (replaces 30269)

DIY Pack
72277 (replaces 97709)

IP Pack

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
0.87 in (22.00 mm)
0.3 in (7.92 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
48 in (1219 mm)
22 in (559 mm)
30 in (762 mm)
22 in (559 mm)

Specifications by lamp and wattage
Nom. Line Current
0.65 A
0.28 A
0.44 A
0.20 A
0.63 A
0.28 A
0.42 A
0.19 A
0.57 A
0.26 A
0.39 A
0.18 A
0.51 A
0.23 A
0.35 A
0.16 A

UL Type 1 Outdoor

NRCan

System Ballast Factor
1.18
1.18
1.34
1.34
1.13
1.13
1.30
1.30
1.10
1.10
1.28
1.28
1.16
1.16
1.32
1.32

UL Type HL

Ballast Efficacy Factor
1.53
1.55
2.79
2.79
1.61
1.63
2.88
2.88
1.68
1.71
3.04
3.04
2.03
2.03
3.47
3.47

FCC – CLASS A Non-Consumer

Power Factor% (>=)
99
98
99
97
99
98
99
96
99
98
99
96
99
97
99
96

UL Class P

cUL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
7
15
10
18

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

See page 195 for warranty information.

Lamp

# of Lamps
Line Volts
System Watts
2
120
55
2
277
54
1
277
42
F32T8
1
120
41
2
120
55
2
277
54
1
120
40
F32T8/WM
1
277
40
2
120
49
2
277
48
1
277
36
F28T8
1
120
33
2
120
46
2
277
46
1
277
34
F25T8
1
120
33
Other compatible lamps: F17T8, F40T8, F32T8/25W

Safety and performance
See page 195 for warranty information.

Nom. Line Current
0.52 A
0.23 A
0.16 A
0.36 A
0.48 A
0.21 A
0.33 A
0.15 A
0.44 A
0.19 A
0.14 A
0.29 A
0.41 A
0.18 A
0.13 A
0.29 A

UL Type 1 Outdoor

NRCan

System Ballast Factor
0.87
0.87
1.02
1.02
0.82
0.82
0.97
0.97
0.80
0.80
0.94
0.94
0.85
0.85
1.03
1.03

UL Type HL

Ballast Efficacy Factor
1.58
1.61
2.44
2.46
1.50
1.52
2.45
2.44
1.63
1.67
2.63
2.89
1.85
1.86
3.06
3.08

FCC – CLASS A Non-Consumer

Power Factor% (>=)
99.0
96.8
95.6
99.0
99.0
96.5
95.0
95.5
99.0
96.2
95.4
99.0
99.0
96.0
94.7
99.0

UL Class P

cUL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
16
19
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

47

HID Electromagnetic
Ballasts

Safety and performance
46

UL Type HL

Ballast Efficacy Factor
1.58
1.60
2.68
2.68
1.57
1.59
2.90
2.90
1.69
1.71
2.96
2.96
2.01
2.03
3.48
3.48

HID Electronic
Ballasts

# of Lamps
Line Volts
System Watts
2
120
77
2
277
76
1
120
48
F32T8
1
277
48
2
120
70
2
277
69
1
120
45
F32T8/WM
1
277
45
2
120
65
2
277
64
1
120
42
F28T8
1
277
42
2
120
57
2
277
57
1
120
38
F25T8
1
277
38
Other compatible lamps: F17T8, F40T8, F32T8/25W

NRCan

72275 – GE-232-MV-N (replaces 30191)

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

UL Type 1 Outdoor

System Ballast Factor
0.79
0.79
0.94
0.94
0.75
0.75
0.90
0.90
0.74
0.74
0.86
0.86
0.81
0.81
0.94
0.94

General characteristics

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black

50 Hz/60 Hz

Nom. Line Current
0.50 A
0.22 A
0.32 A
0.14 A
0.43 A
0.19 A
0.29 A
0.13 A
0.41 A
0.17 A
0.28 A
0.13 A
0.36 A
0.16 A
0.25 A
0.12 A

Compact Fluorescent
Ballasts

Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
High
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics

10 Pack
30198

IP Pack

8.8 in (225.80 mm)
0.87 in (22.00 mm)
0.3 in (7.92 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
48 in (1219 mm)
22 in (559 mm)
30 in (762 mm)
22 in (559 mm)

Sign
Ballasts

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

30198 – GE-232-MV-H

Supply Current Frequency

DIY Pack

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)

Specifications by lamp and wattage
Nom. Line Current
0.28 A
0.13 A
0.25 A
0.12 A
0.22 A
0.11 A
0.21 A
0.10 A
0.08 A
0.16 A

Safety and performance

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black

T12
Fluorescent Ballasts

# of Lamps
Line Volts
1
120
F32T8
1
277
1
120
F32T8/WM
1
277
1
120
F28T8
1
277
1
120
F25T8
1
277
1
277
F17T8
1
120
Other compatible lamps: F32T8/25W

Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Low
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Supply Current Frequency

Specifications by lamp and wattage
Lamp

2 or 1 – F32T8 120 to 277 “L” .77 BF Multivolt ProLine®

General characteristics

Wiring diagram – LFL 1A – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black

Electrical characteristics
Supply Current Frequency

ProLine® T8 Multivolt 120V – 277V

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

72273 – GE-232-MV-L (replaces 30247)

T8
Fluorescent Ballasts

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

72269 – GE-132-MV-N (replaces 30189)
1 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine

ProLine® T8 Multivolt 120V – 277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps

Quick Reference
Guides

gelighting.com

ProLine® T8 Multivolt 120V – 277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
ProLine® T8 Multivolt 120V – 277V
®

General characteristics

Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
High
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
10 Pack
30199

Pallet Pack
30296

DIY Pack

IP Pack

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
48 in (1219 mm)
22 in (559 mm)
30 in (762 mm)
22 in (559 mm)

Safety and performance

Electrical characteristics

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
1.15
1.15
1.27
1.27
1.11
1.11
1.22
1.22

Ballast Efficacy Factor
1.01
1.04
1.47
1.49
1.07
1.09
1.54
1.56

1.07
1.07
1.20
1.20

1.13
1.16
1.66
1.66

FCC – CLASS A Non-Consumer

Order information
10 Pack
30192

®

General characteristics

cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
10
10
10
8
15
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

DIY Pack

IP Pack

UL Type HL

Ballast Efficacy Factor
1.06
1.08
1.54
1.55
1.10
1.11
1.59
1.60

0.80
0.80
0.87
0.87

1.19
1.20
1.68
1.71

FCC – CLASS A Non-Consumer

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
48 in (1219 mm)
22 in (559 mm)
30 in (762 mm)
22 in (559 mm)

4 or 3 – F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®

UL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
13
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16

RoHS Compliant

Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
High
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – LFL 1D – see example on page 72
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Red
Yellow
Blue

Electrical characteristics
50 Hz/60 Hz

Order information
10 Pack
30219

cUL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

ProLine® T8 Multivolt 120V – 277V

Supply Current Frequency

UL Class P

Power Factor% (>=)
99.0
98.3
99.0
97.8
99.0
98.1
99.0
97.6
99.0
98.1
99.0
97.9
99.0
97.4

Pallet Pack
30303

DIY Pack

IP Pack

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)
8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
22 in (559 mm)
36 in (914 mm)
38 in (965 mm)
30 in (762 mm)

Specifications by lamp and wattage
Nom. Line Current
0.70 A
0.31 A
0.55 A
0.24 A
0.62 A
0.27 A
0.50 A
0.22 A
0.63 A
0.27 A
0.57 A
0.25 A
0.46 A
0.20 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.78
0.80
0.87
0.87
0.74
0.74
0.83
0.83

Ballast Efficacy Factor
1.05
1.06
1.46
1.47
1.07
1.08
1.51
1.52

0.74
0.74
0.83
0.83

1.17
1.18
1.67
1.66

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
98
99
97

cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
10
10
10
8
15
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16

Lamp

# of Lamps
Line Volts
System Watts
3
120
145
F40T8
3
277
141
4
120
144
4
277
140
3
120
122
F32T8
3
277
120
4
120
135
4
277
133
3
120
112
F32T8/WM
3
277
110
4
120
122
4
277
120
3
120
102
F28T8
3
277
101
Other compatible lamps: F25T8, F17T8, F32T8/25W

Safety and performance

RoHS Compliant

See page 195 for warranty information.

See page 195 for warranty information.

Nom. Line Current
1.30 A
0.57 A
1.35 A
0.57 A
1.13 A
0.49 A
1.25 A
0.54 A
1.00 A
0.45 A
1.13 A
0.48 A
0.94 A
0.41 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor

Ballast Efficacy Factor

1.15
1.15
1.24
1.24
1.11
1.11
1.20
1.20
1.08
1.08
1.17
1.17

0.79
0.82
1.01
1.03
0.82
0.83
1.07
1.09
0.88
0.90
1.14
1.15

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
98
99
98
99
98
99
98
99
97
99
98
99
97

cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
8
15
10
10
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16

RoHS Compliant

49

HID Electromagnetic
Ballasts

48

UL Type 1 Outdoor

System Ballast Factor
0.87
0.87
0.96
0.96
0.83
0.83
0.92
0.92

HID Electronic
Ballasts

Safety and performance

Nom. Line Current
0.73 A
0.32 A
0.56 A
0.26 A
0.68 A
0.30 A
0.52 A
0.23 A
0.67 A
0.29 A
0.60 A
0.26 A
0.46 A
0.29 A

30219 – GE-432-MV-H

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
# of Lamps
Line Volts
System Watts
3
120
74
3
277
73
2
120
60
F32T8
2
277
59
3
120
69
3
277
68
2
120
56
F32T8/WM
2
277
55
2
120
69
F40T8
2
277
68
3
120
63
3
277
63
2
120
50
F28T8
2
277
50
Other compatible lamps: F25T8, F17T8, F32T8/25W

# of Lamps
Line Volts
System Watts
3
120
81
3
277
80
2
120
62
F32T8
2
277
62
3
120
75
3
277
74
2
120
58
F32T8/WM
2
277
57
2
120
75
F40T8
2
277
73
3
120
67
3
277
67
2
120
52
F28T8
2
277
51
Other compatible lamps: F25T8, F17T8, F32T8/25W

Compact Fluorescent
Ballasts

Order information

Lamp

IP Pack

General characteristics

Wiring diagram – LFL 1C – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black

50 Hz/60 Hz

Pallet Pack
30309

DIY Pack
97710

Lamp

Safety and performance

RoHS Compliant

Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Low
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics

10 Pack
30255

Pallet Pack
30270

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
48 in (1219 mm)
22 in (559 mm)
30 in (762 mm)
22 in (559 mm)

Sign
Ballasts

3 or 2 – F32T8 120 to 277 “L” .77 BF Multivolt ProLine

UL Class P

Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
98
99
97

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

ProLine® T8 Multivolt 120V – 277V

Supply Current Frequency

50 Hz/60 Hz

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)

Specifications by lamp and wattage
Nom. Line Current
0.95 A
0.41 A
0.79 A
0.34 A
0.91 A
0.39 A
0.73 A
0.32 A
0.95 A
0.41 A
0.84 A
0.36 A
0.67 A
0.30 A

30255 – GE-332-MV-L

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagram – LFL 1C – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black

T12
Fluorescent Ballasts

# of Lamps
Line Volts
System Watts
3
120
113
3
277
110
2
120
86
F32T8
2
277
85
3
120
103
3
277
101
2
120
79
F32T8/WM
2
277
78
2
120
102
F40T8
2
277
100
3
120
94
3
277
92
2
120
72
F28T8
2
277
72
Other compatible lamps: F25T8, F17T8, F32T8/25W

Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Supply Current Frequency

Specifications by lamp and wattage
Lamp

3 or 2 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine®

General characteristics

Wiring diagram – LFL 1C – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black

Electrical characteristics
Supply Current Frequency

ProLine® T8 Multivolt 120V – 277V

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

30192 – GE-332-MV-N

T8
Fluorescent Ballasts

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

30199 – GE-332-MV-H
3 or 2 – F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine

ProLine® T8 Multivolt 120V – 277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps

Quick Reference
Guides

gelighting.com

ProLine® T8 Multivolt 120V – 277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
ProLine® T8 Multivolt 120V – 277V
®

General characteristics

Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Low
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
10 Pack
30262

Pallet Pack
30310

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in 43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
22 in (559 mm)
36 in (914 mm)
38 in (965 mm)
30 in (762 mm)

Safety and performance

UL Type 1 Outdoor

UL Type HL

System Ballast Factor

Ballast Efficacy Factor

0.80
0.80
0.87
0.87
0.76
0.76
0.83
0.83
0.73
0.73
0.79
0.79

Electrical characteristics
Supply Current Frequency

FCC – CLASS A Non-Consumer

Order information
10 Pack
30195

UL Class P

cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
15
10
10
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16

®

Dimensions

50 Hz/60 Hz

Order information
DIY Pack
97711

IP Pack

F96T8/WM
F96T8/WMP

# of Lamps
1
1
1
1
1
1

Line Volts
120
277
120
277
120
277

System Watts
60
59
56
54

Safety and performance

Nom. Line Current
0.55 A
0.22 A
0.51 A
0.22 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.89
0.89
0.85
0.85

Ballast Efficacy Factor
1.48
1.50
1.53
1.57

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
96
99
96
99
96
cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
18
10
18
10
18

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
50 / 10
50 / 10
50 / 10
50 / 10

RoHS Compliant

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

30194 – GE-259-MV-N
ProLine® T8 Multivolt 120V – 277V
2 or 1 – F96T8 120 to 277 “N” .87 BF Multivolt ProLine®

Dimensions

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
22 in (559 mm)
36 in (914 mm)
38 in (965 mm)
30 in (762 mm)

Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Black
Blue

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
30194

Pallet Pack
30272

DIY Pack
97712

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
66 in (1676 mm)
25 in (635 mm)
25 in (635 mm)
58 in (1473 mm)

Specifications by lamp and wattage
Nom. Line Current
0.99 A
0.43 A
0.83 A
0.36 A
0.99 A
0.43 A
0.90 A
0.40 A
0.77 A
0.33 A
0.83 A
0.36 A
0.68 A
0.30 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.88
0.88
0.93
0.93

Ballast Efficacy Factor
0.78
0.79
0.99
1.01

0.83
0.83
0.91
0.91
0.80
0.80
0.85
0.85

0.80
0.80
1.04
1.05
0.85
0.87
1.10
1.10

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99.0
98.1
99.0
97.9
99.0
98.1
99.0
98.0
99.0
97.8
99.0
97.9
99.0
97.6

cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
14
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16

Lamp

F96T8

F96T8/WM

F96T8/WMP

# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1

Line Volts
120
277
120
277
120
277
120
277
120
277
120
277

System Watts
113
110
72
72
104
101
67
66

Safety and performance

Nom. Line Current
1.01 A
0.40 A
0.66 A
0.29 A
0.93 A
0.42 A
0.63 A
0.28 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor

Ballast Efficacy Factor

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99.0
98.0
99.0
97.0
99.0
98.4
99.0
97.0

cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
16
10
13
10
17

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
50 / 10
50 / 10
50 / 10
50 / 10

RoHS Compliant

RoHS Compliant

See page 195 for warranty information.

See page 195 for warranty information.

51

HID Electromagnetic
Ballasts

50

F96T8

HID Electronic
Ballasts

Safety and performance

Lamp

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
# of Lamps
Line Volts
System Watts
4
120
113
4
277
110
3
120
93
F32T8
3
277
92
3
120
112
F40T8
3
277
110
4
120
103
4
277
103
3
120
87
F32T8/WM
3
277
86
4
120
93
4
277
92
3
120
77
F28T8
3
277
77
Other compatible lamps: F25T8, F17T8, F32T8/25W

IP Pack

General characteristics

Wiring diagram – LFL 1D – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Red
Yellow
Blue

Electrical characteristics

Lamp

DIY Pack

Compact Fluorescent
Ballasts

Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Pallet Pack
30271

Pallet Pack
30274

8.8 in (225.80 mm)
0.87 in (22.00 mm)
0.3 in (7.92 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
66 in (1676 mm)
25 in (635 mm)
25 in (635 mm)
58 in (1473 mm)

RoHS Compliant

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

General characteristics

10 Pack
30193

50 Hz/60 Hz

9.5 in (241.30 mm)
1.3 in (33.00 mm)
1.18 in (30.00 mm)

Sign
Ballasts

4 or 3 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine

Power Factor% (>=)
99
97
99
98
99
97
99
98
99
97
99
97
99
97

0.80
0.81
1.00
1.01
0.80
0.81
1.05
1.06
0.84
0.85
1.08
1.09

ProLine® T8 Multivolt 120V – 277V

Supply Current Frequency

Wiring diagram – LFL 1A – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Black
Blue

Specifications by lamp and wattage
Nom. Line Current
0.94 A
0.41 A
0.95 A
0.41 A
0.80 A
0.35 A
0.84 A
0.36 A
0.73 A
0.32 A
0.77 A
0.33 A
0.67 A
0.29 A

30193 – GE-432-MV-N

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

T12
Fluorescent Ballasts

# of Lamps
Line Volts
System Watts
3
120
102
F40T8
3
277
100
4
120
100
4
277
98
3
120
87
F32T8
3
277
86
4
120
95
4
277
93
3
120
79
F32T8/WM
3
277
78
4
120
86
4
277
85
3
120
73
F28T8
3
277
72
Other compatible lamps: F25T8, F17T8, F32T8/25W

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

1 – F96T8 120 to 277 “N” .87 BF Multivolt ProLine®

General characteristics

Wiring diagram – LFL 1D – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Red
Yellow
Blue

Electrical characteristics
Supply Current Frequency

ProLine® T8 Multivolt 120V – 277V

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

30195 – GE-159-MV-N

T8
Fluorescent Ballasts

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

30262 – GE-432-MV-L
4 or 3 – F32T8 120 to 277 “L” .77 BF Multivolt ProLine

ProLine® T8 Multivolt 120V – 277V
T8 Instant Start Ballasts For 46 – 59W 4 ft – 8 ft Slimline Lamps

Quick Reference
Guides

gelighting.com

ProLine® T8 Multivolt High Output 120V – 277V
T8 Instant Start Ballasts For 44 – 86W 4 ft – 8 ft HO Lamps
ProLine® T8 Multivolt High Output 120V – 277V
2 or 1 – F96T8HO IS 120 to 277 “N” .87 BF

General characteristics

Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
Pallet Pack
30187

DIY Pack

IP Pack

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)
8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.04 lbs
Side
18 ft
18 AWG
Length (± 1 in)
58 in (1473 mm)
25 in (635 mm)
66 in (1676 mm)
25 in (635 mm)

F96T8

F96T8/WM

F96T8/WMP

F72T8HO

F60T8HO

Electrical characteristics
Supply Current Frequency

F48T8HO

Safety and performance

50 Hz/60 Hz

Order information
10 Pack
23680

Pallet Pack
24161

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
32 in (813 mm)
24 in (610 mm)
32 in (813 mm)

Specifications by lamp and wattage
Nom. Line Current
1.30 A
0.56 A
0.82 A
0.36 A
1.29 A
0.52 A
0.79 A
0.33 A
1.23 A
0.51 A
0.77 A
0.33 A
1.11 A
0.47 A
0.69 A
0.30 A
1.02 A
0.43 A
0.64 A
0.28 A
0.87 A
0.37 A
0.55 A
0.25 A
0.84 A
0.35 A
0.24 A
0.53 A
0.72 A
0.30 A
0.20 A
0.45 A
0.70 A
0.30 A
0.45 A
0.20 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.80
0.82
0.82
0.82
1.17
1.17

Ballast Efficacy Factor
0.54
0.57
0.89
0.91
0.82
0.84

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
97
98
96
99
97
99
97
99
98
99
97
99
98
99
96
99
97
99
95
99
97
99
94
99
97
94
99
99
96
93
99
99
96
99
93
cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
14
10
19
10
14
10
19
10
14
10
20
10
15
10
21
10
16
10
22
10
17
11
23
10
18
23
11
10
20
27
13
10
21
13
26

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

Lamp
F32T8
F32T8/WM
F25T12
F28T8
F25T8
F17T8
FE15T8

# of Lamps
1
1
1
1
1
1
1

Line Volts
120
120
120
120
120
120
120

System Watts
30
28
25
25
24
18
15

Safety and performance

Nom. Line Current
0.26 A
0.24 A
0.22 A
0.22 A
0.21 A
0.16 A
0.13 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.87
0.86
0.87
0.84
0.87
0.91
0.91

Ballast Efficacy Factor
2.90
3.07
3.48
3.36
3.62
5.05
6.06

FCC – CLASS A Non-Consumer

cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
60 / 16
0 / -18
60 / 16
0 / -18
0 / -18
0 / -18

RoHS Compliant

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage

23681 – GE-132-277-N
ProLine® T8 Instant Start High Performance
1 – F32T8 277V “N” .87 BF ProLine®

General characteristics

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Electronic – Standard Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – LFL 1A – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
23681

UL Class P

Power Factor% (>=)
99
99
99
99
99
99
99

Pallet Pack
24162

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)

Compact Fluorescent
Ballasts

F58T8

System Watts
146
143
92
90
142
139
87
86
136
134
86
86
125
123
78
77
115
114
73
72
98
97
62
62
95
92
62
60
78
78
50
49
78
77
51
51

Wiring diagram – LFL 1A – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

Sign
Ballasts

F40T8

Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
277
120
120
277
277
120
120
277
120
277

Electronic – Standard Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
32 in (813 mm)
24 in (610 mm)
32 in (813 mm)

# of Lamps
1
1
1
1
1
1
1

Line Volts
277
277
277
277
277
277
277

System Watts
30
28
26
25
25
18
15

Safety and performance

See page 195 for warranty information.

See page 195 for warranty information.

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.87
0.86
0.84
0.87
0.87
0.91
0.91

Ballast Efficacy Factor
2.90
3.07
3.23
3.48
3.48
5.05
6.06

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
99
97
97
97
96
94
cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
11
11
14
16

Min. Starting Temp (°F/°C)
0 / -18
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

53

HID Electromagnetic
Ballasts

52

Nom. Line Current
0.12 A
0.11 A
0.97 A
0.10 A
0.10 A
0.07 A
0.06 A

HID Electronic
Ballasts

Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F25T12
F25T8
F17T8
FE15T8

T12
Fluorescent Ballasts

F96T8/HO

# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

1 – F32T8 120V “N” .87 BF ProLine®

General characteristics

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
White
Red
Black

Electrical characteristics
Supply Current Frequency

ProLine® T8 Instant Start High Performance

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage

23680 – GE-132-120-N

T8
Fluorescent Ballasts

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

30176 – GE-286-HO-MV-N

10 Pack
30176

ProLine® T8 Instant Start High Performance
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps

Quick Reference
Guides

gelighting.com

ProLine® T8 Instant Start High Performance
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
ProLine® T8 Instant Start High Performance
®

General characteristics

Dimensions
Electronic – Standard Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
10 Pack
23671

Pallet Pack
24163

DIY Pack

IP Pack

F32T8

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
32 in (813 mm)
24 in (610 mm)
32 in (813 mm)

F28T8
F25T12
F25T8
F40T8
F17T8
FE15T8

Line Volts
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120

System Watts
57
36
53
33
48
30
46
30
45
28
43
31
20
25
17

System Ballast Factor
0.87
0.94
0.86
0.94
0.84
0.91
0.87
0.94
0.87
0.97

Ballast Efficacy Factor
1.52
2.61
1.62
2.84
1.75
3.03
1.89
3.13
1.93
3.46

0.91
0.97
0.91
0.98

2.93
4.85
3.64
5.76

NRCan

UL Type HL

FCC – CLASS A Non-Consumer

Order information
10 Pack
23673

Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99
99
99
98
98
98

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
13
11
15

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

UL Class P

cUL Listed

UL Listed

®

General characteristics

Dimensions
Electronic – Standard Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
Pallet Pack
24164

F32T8/WM
F28T8
F25T12

F17T8
FE15T8

Safety and performance
54

F28T8
F25T12
F25T8
F17T8

Line Volts
120
120
120
120
120
120
120
120
120
120
120
120
120
120

System Watts
85
65
79
60
78
72
54
69
54
67
51
47
30
30

DIY Pack

IP Pack

System Watts
57
37
53
34
48
31
47
31
45
29
44
32
22
26
18

Nom. Line Current
0.73 A
0.56 A
0.68 A
0.51 A
0.67 A
0.62 A
0.47 A
0.60 A
0.46 A
0.58 A
0.44 A
0.41 A
0.31 A
0.26 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.87
0.94
0.86
0.94

Ballast Efficacy Factor
1.02
1.44
1.08
1.56

0.84
0.91
0.87
0.94
0.87
0.97
0.91
0.97
0.98

1.16
1.68
1.26
1.74
1.29
1.90
1.93
3.23
3.26

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99
99
99
99
98
cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
12
13

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
0 / -18
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage

23674 – GE-332-277-N
ProLine® T8 Instant Start High Performance
3 or 2 – F32T8 277V “N” .87 BF ProLine®

Dimensions

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
32 in (813 mm)
24 in (610 mm)
32 in (813 mm)

Electronic – Standard Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – LFL 1C – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
23674

Pallet Pack
24166

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
32 in (813 mm)
24 in (610 mm)
32 in (813 mm)

Specifications by lamp and wattage
Nom. Line Current
0.22 A
0.14 A
0.20 A
0.13 A
0.18 A
0.12 A
0.18 A
0.12 A
0.17 A
0.11 A
0.16 A
0.12 A
0.08 A
0.10 A
0.07 A

UL Type 1 Outdoor

NRCan

System Ballast Factor
0.87
0.94
0.86
0.94
0.84
0.91
0.87
0.94
0.87
0.97

Ballast Efficacy Factor
1.52
2.54
1.62
2.76
1.75
2.93
1.85
3.03
1.93
3.34

0.91
0.97
0.91
0.98

2.84
4.40
3.50
5.44

UL Type HL

FCC – CLASS A Non-Consumer

Power Factor% (>=)
99
99
99
99
99
97
98
97
98
97
99
98
96
97
95
UL Class P

cUL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Listed

THD% (<=)
10
10
10
10
10
10
10
13
10
13
10
12
16
14
17

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

See page 195 for warranty information.

Lamp
F32T8
F32T8/WM
F40T8
F28T8
F25T12
F25T8
F17T8
FE15T8

# of Lamps
3
2
3
2
2
3
2
3
2
3
2
3
2
3
2

Line Volts
277
277
277
277
277
277
277
277
277
277
277
277
277
277
277

System Watts
84
64
78
59
77
70
53
68
53
65
50
46
36
36
28

Safety and performance
See page 195 for warranty information.

Nom. Line Current
0.31 A
0.24 A
0.29 A
0.22 A
0.29 A
0.26 A
0.20 A
0.25 A
0.20 A
0.24 A
0.19 A
0.17 A
0.13 A
0.14 A
0.11 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.87
0.94
0.86
0.94

Ballast Efficacy Factor
1.03
1.46
1.10
1.59

0.84
0.91
0.87
0.94
0.87
0.97
0.91
0.97
0.91
0.98

1.20
1.71
1.27
1.77
1.33
1.94
1.97
2.69
2.52
3.50

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
99
99
99
99
99
98
99
98
99
98
98
97
98
97
cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
10
10
10
11
10
12
12
15
15
16

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
0 / -18
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

55

HID Electromagnetic
Ballasts

F25T8
F40T8

F32T8/WM
F40T8

# of Lamps
3
2
3
2
2
3
2
3
2
3
2
3
2
2

HID Electronic
Ballasts

F32T8

F32T8

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Line Volts
277
277
277
277
277
277
277
277
277
277
277
277
277
277
277

Lamp

General characteristics

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

Electrical characteristics
Supply Current Frequency

IP Pack

Compact Fluorescent
Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

DIY Pack

Sign
Ballasts

ProLine® T8 Instant Start High Performance

# of Lamps
2
1
2
1
2
1
2
1
2
1
1
2
1
2
1

Pallet Pack
24165

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
32 in (813 mm)
24 in (610 mm)
32 in (813 mm)

RoHS Compliant

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage

23672 – GE-232-277-N

Lamp

50 Hz/60 Hz

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)

Specifications by lamp and wattage
Nom. Line Current
0.49 A
0.31 A
0.45 A
0.29 A
0.41 A
0.26 A
0.40 A
0.26 A
0.38 A
0.25 A
0.37 A
0.27 A
0.18 A
0.22 A
0.15 A

UL Type 1 Outdoor

2 or 1 – F32T8 277V “N” .87 BF ProLine

Wiring diagram – LFL 1C – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

Electrical characteristics
Supply Current Frequency

Safety and performance

Safety and performance

10 Pack
23672

Electronic – Standard Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

T12
Fluorescent Ballasts

F32T8/WM

# of Lamps
2
1
2
1
2
1
2
1
2
1
1
2
1
2
1

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

3 or 2 – F32T8 120V “N” .87 BF ProLine®

General characteristics

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

Electrical characteristics
Supply Current Frequency

ProLine® T8 Instant Start High Performance

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage

23673 – GE-332-120-N

T8
Fluorescent Ballasts

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage

23671 – GE-232-120-N
2 or 1 – F32T8 120V “N” .87 BF ProLine

ProLine® T8 Instant Start High Performance
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps

Quick Reference
Guides

gelighting.com

ProLine® T8 Instant Start High Performance
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
ProLine® T8 Instant Start High Performance
®

General characteristics

Dimensions
Electronic – Standard Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
10 Pack
23675

Pallet Pack
24167

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
45 in (1143 mm)
32 in (813 mm)
32 in (813 mm)

F32T8/WM
F28T8
F25T12
F25T8
F17T8
FE15T8

Line Volts
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120

System Watts
113
93
113
105
86
96
77
91
75
87
72
60
50
48
40

Safety and performance

UL Type HL

System Ballast Factor
0.87
0.94

Ballast Efficacy Factor
0.76
1.01

Power Factor% (>=)
0.87
0.94

0.86
0.94
0.84
0.91
0.87
0.94
0.87
0.97
0.91
0.97
0.91
0.98

0.81
1.09
0.87
1.18
0.95
1.25
1.00
1.34
1.51
1.94
1.89
2.45

0.86
0.94
0.84
0.91
0.87
0.94
0.87
0.97
0.91
0.97
0.91
0.98

FCC – CLASS A Non-Consumer

Electrical characteristics
Supply Current Frequency

Order information

®

General characteristics

UL Class P

cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
11
12
14

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

DIY Pack

IP Pack

F32T8/WM
F28T8
F25T12

F17T8
FE15T8

Safety and performance
56

F96T8/WMP

Line Volts
120
120
120
120
120
120

System Watts
112
71
104
65

Safety and performance

Nom. Line Current
0.96 A
0.61 A
0.89 A
0.56 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.87
1.04
0.87
1.04

Ballast Efficacy Factor
0.77
1.46
0.83
1.60

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
99
99
99
99
99
cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage

23678 – GE-259-277-N
ProLine® T8 Instant Start High Performance
2 or 1 – F96T8 277V “N” .87 BF ProLine®

Dimensions

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
45 in (1143 mm)
32 in (813 mm)
32 in (813 mm)

Electronic – Standard Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
23678

Pallet Pack
24170

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
66 in (1676 mm)
25 in (635 mm)
58 in (1473 mm)

Specifications by lamp and wattage
Nom. Line Current
0.41 A
0.41 A
0.34 A
0.38 A
0.32 A
0.35 A
0.29 A
0.33 A
0.28 A
0.32 A
0.26 A
0.22 A
0.19 A
0.18 A
0.15 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor

Ballast Efficacy Factor

0.87
0.94
0.86
0.94
0.84
0.91
0.87
0.94
0.87
0.97
0.91
0.97
0.91
0.98

0.79
1.02
0.84
1.11
0.90
1.21
0.97
1.25
1.02
1.38
1.54
1.97
1.93
2.51

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)

cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
12
13
14
15

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

Lamp
F96T8
F96T8/WM
F96T8/WMP

# of Lamps
2
1
2
1
1
2

Line Volts
277
277
277
277
277
277

System Watts
110
71
102
66

Safety and performance

Nom. Line Current
0.41 A
0.27 A
0.38 A
0.25 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.87
1.04
0.87
1.04

Ballast Efficacy Factor
0.79
1.46
0.85
1.57

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
99
99
98
98
99
cUL Listed

UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7

THD% (<=)
10
13
10
13
13
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

RoHS Compliant

RoHS Compliant

See page 195 for warranty information.

See page 195 for warranty information.

57

HID Electromagnetic
Ballasts

F25T8

System Watts
111
110
92
102
84
93
75
89
75
85
70
59
49
47
39

F96T8/WM

# of Lamps
2
1
2
1
1
2

HID Electronic
Ballasts

F32T8

Line Volts
277
277
277
277
277
277
277
277
277
277
277
277
277
277
277

F96T8

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
# of Lamps
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3

Lamp

Compact Fluorescent
Ballasts

Order information

Lamp
F40T8

IP Pack

General characteristics

Wiring diagram – LFL 1D – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Yellow
Red
Blue

50 Hz/60 Hz

Pallet Pack
24168

DIY Pack

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
66 in (1676 mm)
25 in (635 mm)
58 in (1473 mm)

RoHS Compliant

Dimensions
Electronic – Standard Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics

10 Pack
23676

Pallet Pack
24169

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)

Sign
Ballasts

ProLine® T8 Instant Start High Performance

Supply Current Frequency

50 Hz/60 Hz

10 Pack
23677

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage

23676 – GE-432-277-N

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

Specifications by lamp and wattage
Nom. Line Current
0.97 A
0.80 A
0.97 A
0.90 A
0.74 A
0.81 A
0.66 A
0.78 A
0.65 A
0.74 A
0.62 A
0.52 A
0.43 A
0.42 A
0.35 A

UL Type 1 Outdoor

4 or 3 – F32T8 277V “N” .87 BF ProLine

Electronic – Standard Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

T12
Fluorescent Ballasts

F32T8
F40T8

# of Lamps
4
3
3
4
3
4
3
4
3
4
3
4
3
4
3

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

2 or 1 – F96T8 120V Normal Light .87 BF ProLine®

General characteristics

Wiring diagram – LFL 1D – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Yellow
Red
Blue

Electrical characteristics
Supply Current Frequency

ProLine® T8 Instant Start High Performance

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage

23677 – GE-259-120-N

T8
Fluorescent Ballasts

• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage

23675 – GE-432-120-N
4 or 3 – F32T8 120V “N” .87 BF ProLine

ProLine® T8 Instant Start High Performance
T8 Instant Start Ballasts For 46 – 59W 4 ft – 8 ft Slimline Lamps

Quick Reference
Guides

gelighting.com

Residential Grade ProLine® T8 120V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps

Electromagnetic T8 Ballasts
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps

97782 – GE232-120-RES

87125 – GEM232T8RS120

Residential Grade ProLine® T8 120V

Electromagnetic T8 Ballasts

2 or 1 – F32T8 120V “N” .87 BF Residential ProLine®

2 – F32T8, RS, 120V, Magnetic Ballast (M232SR120C)

60 Hz
50 Hz

Order information
Pallet Pack

DIY Pack
70137

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
36 in (914 mm)
31 in (787 mm)
25 in (635 mm)
38 in (965 mm)
25 in (635 mm)

Safety and performance

System Watts
53
32
51
32
46
29
43
28
31
20

Nom. Line Current
0.81 A
0.55 A
0.79 A
0.54 A
0.72 A
0.50 A
0.69 A
0.48 A
0.52 A
0.37 A

RoHS Compliant

UL Type 1 Outdoor

System Ballast Factor
0.83
0.99
0.82
0.99
0.81
0.97
0.88
1.04
0.88
1.03
UL Type HL

Ballast Efficacy Factor
1.56
3.09
1.60
3.09
1.76
3.34
2.04
3.71
2.83
5.15

ANSI – C62.41

UL Class P

Power Factor% (>=)
5
48
5
48
5
48
5
48
49
45

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

FCC Part 18 Class B at 120 Volts

THD% (<=)
145
170
146
170
152
177
155
178
172
195

A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
60 Hz

Order information
10 Pack
87125

Pallet Pack

DIY Pack

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

# of Lamps
2

Line Volts
120

System Watts
32

Safety and performance

Dimensions

A (20-24 decibels)
Thermally protected

60 Hz
50 Hz

F32T8/WM
F28T8
F25T8

Safety and performance

58

UL Listed

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
31 in (787 mm)
31 in (787 mm)
25 in (635 mm)
38 in (965 mm)

Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
87130

Pallet Pack

DIY Pack

IP Pack
87130

Wiring diagram – LFL PS2 – see example on page 73
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White and Black
Yellow

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)
8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.60 lbs
Side
10 ft
18 AWG
Length (± 1 in)
26 in (660 mm)
20 in (508 mm)
36 in (914 mm)

Specifications by lamp and wattage
Nom. Line Current
1.62 A
1.38 A
1.50 A
1.29 A
1.42 A
1.23 A
1.31 A
1.13 A
0.98 A
0.84 A

UL Type 1 Outdoor

RoHS Compliant

System Ballast Factor
0.83
0.88
0.81
0.88
0.79
0.87
0.87
0.94
0.86
0.93
UL Type HL

Ballast Efficacy Factor
0.79
1.02
0.82
1.08
0.87
1.16
1.04
1.38
1.48
1.93

ANSI – C62.41

Power Factor% (>=)
5
5
5
5
5
5
5
5
48
44

FCC Part 18 Class B at 120 Volts

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
0.19
1.7
1.7
1.7
1.7

UL Class P

cUL Listed

THD% (<=)
147
157
150
159
155
165
158
167
175
185

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

Lamp
F32T8
F25T8
F17T8

# of Lamps
2
2
2

Line Volts
277
277
277

System Watts
77
60
47

Safety and performance

Nom. Line Current
0.28 A
0.22 A
0.18 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.98
1.00
1.09
UL Class P

Ballast Efficacy Factor
1.27
1.66
2.31

Power Factor% (>=)
98
98
96

Crest Factor (<=)
1.7
1.7
1.7

THD% (<=)
20
20
25

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
50 / 10

UL Listed

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

59

HID Electromagnetic
Ballasts

F17T8

Min. Starting Temp (°F/°C)
50 / 10

HID Electronic
Ballasts

F32T8

System Watts
105
86
98
81
90
75
83
68
58
48

THD% (<=)
18

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Line Volts
120
120
120
120
120
120
120
120
120
120

Crest Factor (<=)
1.7

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)
• Great for areas requiring no EMI/RFI noise

General characteristics

Wiring diagram – LFL 1D – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
Blue
White and Black
Yellow

Order information

# of Lamps
4
3
4
3
4
3
4
3
4
3

UL Class P

Power Factor% (>=)
98

Compact Fluorescent
Ballasts

Electronic – Standard Instant Start
Instant start
Parallel
10%
104°F (40°C)
70°C (158°F)
Normal

Electrical characteristics

Lamp

CSA

Ballast Efficacy Factor
2.93

2 – F32T8, RS, 277V, Magnetic Ballast (M232SR277C)

General characteristics

DIY Pack
70138

UL Type HL

System Ballast Factor
0.94

Sign
Ballasts

Electromagnetic T8 Ballasts

4 or 3 – F32T8 120V “N” .87 BF Residential ProLine®

Pallet Pack

8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.60 lbs
Side
10 ft
18 AWG
Length (± 1 in)
26 in (660 mm)
20 in (508 mm)
36 in (914 mm)

cUL Listed

Residential Grade ProLine® T8 120V

10 Pack
97783

Nom. Line Current
0.60 A

UL Type 1 Outdoor

87130 – GEM232T8RS277

Supply Current Frequency
Supply Current Frequency (MIN)

IP Pack
87125

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)

Specifications by lamp and wattage
Lamp
F32T8

97783 – GE432-120-RES

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagram – LFL PS2 – see example on page 73
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White and Black
Yellow

T12
Fluorescent Ballasts

# of Lamps
Line Volts
2
120
F32T8
1
120
2
120
F32T8/WM
1
120
2
120
F28T8
1
120
2
120
F25T8
1
120
2
120
F17T8
1
120
Other compatible lamps: F32T8/25W

Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Supply Current Frequency

Specifications by lamp and wattage
Lamp

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Wiring diagram – LFL 1B – see example on page 72
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
Blue
White and Black
Yellow
Black

Electrical characteristics
Supply Current Frequency
Supply Current Frequency (MIN)

10 Pack
97782

General characteristics

Dimensions
Electronic – Standard Instant Start
Instant start
Parallel
10%
104°F (40°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Thermally protected

T8
Fluorescent Ballasts

General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)
• Great for areas requiring no EMI/RFI noise

Quick Reference
Guides

gelighting.com

UltraStart® T8 Programmed Start
T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
UltraStart® T8 Programmed Start
®

2 – F32T8 120V Normal Light .87 BF <10% THD UltraStart

General characteristics

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
Pallet Pack
29630

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
48 in (1219 mm)
25 in (635 mm)

Safety and performance

System Watts
57
35
54
33
49
30
45
28
32
20
RoHS Compliant

Nom. Line Current
0.49 A
0.29 A
0.46 A
0.28 A
0.42 A
0.26 A
0.39 A
0.24 A
0.28 A
0.17 A
UL Type 1 Outdoor

System Ballast Factor
0.89
1.03
0.88
1.02
0.85
0.97
0.89
1.04
0.89
1.02
UL Type HL

Ballast Efficacy Factor
1.56
2.94
1.62
3.09
1.73
3.23
1.97
3.71
2.78
5.10
NRCan

Power Factor% (>=)
99
99
99
99
99
99
99
98
99
98

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

ANSI – C62.41

UL Class P

THD% (<=)
10
10
10
10
10
10
10
10
10
10
cUL Listed

Electronic – Programmed/ Rapid Start
Programmed start
Parallel
10%
104°F (40°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Thermally protected, Universal voltage

Electrical characteristics
Supply Current Frequency
Supply Current Frequency (MIN)

50 Hz/Supply Current Frequency (MIN)/ 50 Hz/ 60 (MIN)
50 Hz/60 Hz

Order information
10 Pack
96714
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
UL Listed

Pallet Pack
96717

UltraStart® T8 Programmed Start
®

2 – F32T8 277V Normal Light .87 BF <10% THD UltraStart

General characteristics

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Specifications by lamp and wattage
# of Lamps
Line Volts
System Watts
2
120
59
2
277
58
1
120
37
F32T8
1
277
37
2
120
55
2
277
54
1
120
34
F32T8/WM
1
277
34
2
120
51
2
277
50
1
120
32
F28T8
1
277
32
Other compatible lamps: F17T8, F25T8, F32T8/25W

Electrical characteristics
Supply Current Frequency

50 Hz/ 60 Hz

Order information
10 Pack
29622

Pallet Pack
29632

DIY Pack

IP Pack

RoHS Compliant

FCC – CLASS A Non-Consumer

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
48 in (1219 mm)
25 in (635 mm)

UltraStart® T8 Programmed Start
2 or 1 – F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

ANSI – C62.41

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

RoHS Compliant

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10

UL Listed

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
104°F (40°C)
70°C (158°F)
Low
Active
A (20-24 decibels)
Anti-striation control, Thermally protected, Universal voltage

Wiring diagram – LFL PS2 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue and Red
White
Yellow

Electrical characteristics
Supply Current Frequency (MIN)

50 Hz/60 Hz

Order information
10 Pack
96720

UL Class P

Power Factor% (>=)
99
96
98
93
99
96
98
93
99
95
98
92

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Anti-striation control for better light quality, with no striations
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Multi-voltage technology handles voltage from 120 to 277V
• Parallel lamp operation means system maintenance is easier to manage

96720 – GE232-MVPS-L

Pallet Pack

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
25 in (635 mm)
48 in (1219 mm)

Specifications by lamp and wattage
Nom. Line Current
0.21 A
0.14 A
0.21 A
13.00 A
0.19 A
0.12 A
0.18 A
0.11 A
0.12 A
0.08 A
UL Type 1 Outdoor

System Ballast Factor
0.89
1.03
0.88
1.01
0.86
0.98
0.90
1.03
0.90
1.02
ANSI – C62.41

Ballast Efficacy Factor
1.56
2.86
1.62
2.97
1.75
3.16
1.95
3.67
2.81
4.85

UL Type HL

Power Factor% (>=)
97
95
97
94
97
94
96
93
93
88

FCC – CLASS A Non-Consumer

NRCan

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Class P

THD% (<=)
10
10
10
10
10
10
10
13
10
15
cUL Listed

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
UL Listed

Lamp

# of Lamps
Line Volts
2
120
2
277
1
120
F32T8
1
277
2
120
2
277
1
120
F32T8/WM
1
277
2
120
2
277
1
120
F28T8
1
277
2
277
2
120
1
277
F25T8
1
120
Other compatible lamps: F17T8, F32T8/25W

System Watts
47
47
30
30
44
44
28
28
41
41
26
26
38
37
25
24

Safety and performance
60

Ballast Efficacy Factor
1.50
1.53
2.83
2.83
1.60
1.62
3.00
3.00
1.68
1.72
3.12
3.12

See page 195 for warranty information.

See page 195 for warranty information.

Nom. Line Current
0.39 A
0.17 A
0.28 A
0.11 A
0.36 A
0.16 A
0.26 A
0.11 A
0.34 A
0.15 A
0.24 A
0.10 A
0.14 A
0.31 A
0.09 A
0.23 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.71
0.71
0.81
0.81
0.67
0.67
0.79
0.79
0.65
0.65
0.77
0.77
0.73
0.73
0.86
0.86

Ballast Efficacy Factor
1.51
1.51
2.70
2.70
1.52
1.52
2.82
2.82
1.58
1.58
2.96
2.96
1.92
1.97
3.44
3.58

FCC – CLASS A Non-Consumer

ANSI – C62.41

Power Factor% (>=)
99
95
98
90
99
95
98
90
99
94
98
90
94
99
85
97

RoHS Compliant

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
16
10
16
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

61

HID Electromagnetic
Ballasts

Safety and performance

System Watts
57
36
54
34
49
31
46
28
32
21

UL Type HL

System Ballast Factor
0.89
0.89
1.05
1.05
0.88
0.88
1.02
1.02
0.86
0.86
1.00
1.00

HID Electronic
Ballasts

# of Lamps
Line Volts
2
277
F32T8
1
277
2
277
F32T8/WM
1
277
2
277
F28T8
1
277
2
277
F25T8
1
277
2
277
F17T8
1
277
Other compatible lamps: F32T8/25W

UL Type 1 Outdoor

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

Nom. Line Current
0.48 A
0.21 A
0.30 A
0.14 A
0.45 A
0.20 A
0.28 A
0.13 A
0.42 A
0.18 A
0.26 A
0.12 A

General characteristics

Wiring diagram – LFL PS2 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue and Red
Yellow
White

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
25 in (635 mm)
48 km

Compact Fluorescent
Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)

Sign
Ballasts

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

DIY Pack

Lamp

Safety and performance

29622 – GE-232-277-PS-N

Wiring diagram – LFL 4a – see example on page 73
Case dimensions – Ref Drawing A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue and Red
White
Yellow

T12
Fluorescent Ballasts

# of Lamps
Line Volts
2
120
F32T8
1
120
2
120
F32T8/WM
1
120
2
120
F28T8
1
120
2
120
F25T8
1
120
2
120
F17T8
1
120
Other compatible lamps: F32T8/25W

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

2 or 1 – F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®

General characteristics

Wiring diagram – LFL PS2 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue and Red
Yellow
White

Electrical characteristics
Supply Current Frequency

UltraStart® T8 Programmed Start

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• < 10% THD, > 99% power factor
• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Anti-striation control for better light quality, with no striations
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Multi-voltage technology handles voltage from 120 to 277V

96714 – GE232-MVPS-N

T8
Fluorescent Ballasts

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

29621 – GE-232-120-PS-N

10 Pack
29621

UltraStart® T8 Programmed Start
T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps

Quick Reference
Guides

gelighting.com

UltraStart® T8 Programmed Start
T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
UltraStart® T8 Programmed Start
®

2 – F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart

General characteristics

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
High
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
Pallet Pack
29651

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
2.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
25 in (635 mm)
25 in (635 mm)
48 in (1219 mm)
33 in (838 mm)

System Watts
75
74
47
46
69
69
43
43
63
62
39
38
59
59
37
37

Safety and performance

Nom. Line Current
0.64 A
0.28 A
0.19 A
0.40 A
0.60 A
0.27 A
0.36 A
0.18 A
0.54 A
0.25 A
0.16 A
0.32 A
0.50 A
0.24 A
0.32 A
0.15 A
UL Type HL

System Ballast Factor
1.15
1.15
1.37
1.37
1.14
1.14

Ballast Efficacy Factor
1.53
1.55
2.91
2.97
1.65
1.65

1.34
1.10
1.11
1.29

3.11
1.74
1.79
3.30

1.14
1.14
1.34
1.34

1.93
1.93
3.62
3.62

RoHS Compliant

FCC – CLASS A Non-Consumer

2 – F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

General characteristics

ANSI – C62.41

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
16
10
21

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

Order information
DIY Pack

IP Pack

RoHS Compliant

UL Type 1 Outdoor

System Ballast Factor
0.89
1.00
0.87
0.98
0.85
0.95
0.89
0.99
0.88
0.98
ANSI – C62.41

Ballast Efficacy Factor
1.05
1.56
1.08
1.63
1.18
1.75
1.34
1.94
1.95
2.80

UL Type HL

NRCan

Power Factor% (>=)
99.00
99.00
0.99
99.00
99.00
99.00
99.00
99.00
99.00
99.00

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

FCC – CLASS A Non-Consumer

UL Class P

THD% (<=)
10
10
10
10
10
10
10
10
10
10
cUL Listed

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
UL Listed

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

29624 – GE-332-277-PS-N
UltraStart® T8 Programmed Start
3 – F32T8 277V Normal Light .87 BF <10% THD UltraStart®

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
25 in (635 mm)
48 in (1219 mm)

Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – LFL PS3 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Red/White
Yellow

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
29624

Pallet Pack
29634

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)

Specifications by lamp and wattage
Nom. Line Current
0.39 A
0.19 A
0.12 A
0.24 A
0.15 A
0.24 A
0.22 A
0.20 A
0.12 A
0.15 A
0.12 A
0.20 A
0.31 A
0.15 A
0.10 A
0.10 A
0.20 A
UL Type 1 Outdoor

System Ballast Factor
0.60
0.60
0.70
0.70
0.59
0.59

Ballast Efficacy Factor
1.33
1.36
2.50
2.59
1.40
1.40

0.68
0.59
0.59
0.67

2.51
1.51
1.51
2.68

0.61
0.61

1.69
1.69

0.68
0.68

2.95
3.09

ANSI – C62.41

UL Type HL

NRCan

Power Factor% (>=)
98.0
90.0
83.0
98.0
99.0
87.0
0.9
81.0
99.0
86.0
79.0
98.0
98.0
87.0
79.0
79.0
98.0

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

FCC Part 18 Class B at 120 Volts

UL Class P

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
15
16
10
cUL Listed

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

Lamp

# of Lamps
Line Volts
3
277
2
277
3
277
F32T8/WM
2
277
3
277
F28T8
2
277
3
277
F25T8
2
277
3
277
F17T8
2
277
Other compatible lamps: F32T8/25W
F32T8

Safety and performance

System Watts
85
65
80
61
72
55
67
51
47
36
RoHS Compliant

Nom. Line Current
0.32 A
0.25 A
0.30 A
0.23 A
0.27 A
0.21 A
0.26 A
0.20 A
0.18 A
0.14 A
UL Type 1 Outdoor

System Ballast Factor
0.89
1.00
0.88
0.98
0.86
0.95
0.89
0.99
0.89
0.98
ANSI – C62.41

Ballast Efficacy Factor
1.04
1.53
1.10
1.60
1.19
1.72
1.32
1.94
1.89
2.72

UL Type HL

Power Factor% (>=)
97
97
98
98
98
98
97
96
96
94

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
11
10
13

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

63

HID Electromagnetic
Ballasts

Safety and performance

62

System Watts
45
44
28
27
42
42
27
27
39
39
25
24
36
36
23
23
22

RoHS Compliant

Nom. Line Current
0.71 A
0.56 A
0.69 A
0.52 A
0.62 A
0.47 A
0.57 A
0.43 A
0.39 A
0.31 A

HID Electronic
Ballasts

# of Lamps
Line Volts
2
120
2
277
1
277
F32T8
1
120
2
120
2
277
1
120
F32T8/WM
1
277
2
120
2
277
1
277
F28T8
1
120
2
120
2
277
1
277
1
277
F25T8
1
120
Other compatible lamps: F17T8, F32T8/25W

Safety and performance

System Watts
84
64
80
60
72
54
66
51
45
35

UL Listed

Specifications by lamp and wattage
Lamp

# of Lamps
Line Volts
3
120
F32T8
2
120
3
120
F32T8/WM
2
120
3
120
F28T8
2
120
3
120
F25T8
2
120
3
120
F17T8
2
120
Other compatible lamps: F32T8/25W

Compact Fluorescent
Ballasts

50 Hz/ 60 Hz

IP Pack

General characteristics

Wiring diagram – LFL PS2 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White and Black
Yellow

Electrical characteristics

DIY Pack

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)

Specifications by lamp and wattage

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
Ultra low
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Pallet Pack
29665

Pallet Pack
29633

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)

Sign
Ballasts

UltraStart® T8 Programmed Start

Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
29623

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

29671 – GE-232-MVPS-XL

10 Pack
29671

Power Factor% (>=)
98
94
90
98
98
95
98
90
94
98
89
98
98
93
98
87

Wiring diagram – LFL PS3 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Red/White
Yellow

Electrical characteristics
Supply Current Frequency

Lamp

UL Type 1 Outdoor

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

T12
Fluorescent Ballasts

# of Lamps
Line Volts
2
120
2
277
1
277
F32T8
1
120
2
120
2
277
1
120
F32T8/WM
1
277
2
120
2
277
1
277
F28T8
1
120
2
120
2
277
1
120
F25T8
1
277
Other compatible lamps: F17T8, F32T8/25W

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

3 – F32T8 120V Normal Light .87 BF <10% THD UltraStart®

General characteristics

Wiring diagram – LFL PS2 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
Black
White
Yellow
Blue

Electrical characteristics
Supply Current Frequency

UltraStart® T8 Programmed Start

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

29623 – GE-332-120-PS-N

T8
Fluorescent Ballasts

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

29675 – GE-232-MVPS-H

10 Pack
29675

UltraStart® T8 Programmed Start
T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps

Quick Reference
Guides

gelighting.com

UltraStart® T8 Programmed Start
T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
UltraStart® T8 Programmed Start
®

3 – F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart

General characteristics

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
High
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
Pallet Pack
29656

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
2.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)

System Watts
110
108
82
82
102
100
77
76
92
91
69
58
86
85
65
64

Safety and performance

Electrical characteristics
Supply Current Frequency (MIN)

UL Type HL

System Ballast Factor
1.15
1.15
1.28

Ballast Efficacy Factor
1.04
1.06
1.56

1.13
1.14

1.10
1.14

1.26
1.09
1.10
1.23

1.65
1.18
1.20
1.78

1.14
1.14
1.25

1.32
1.34
1.92

RoHS Compliant

FCC – CLASS A Non-Consumer

Order information
10 Pack
96721

®

3 – F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart

General characteristics

ANSI – C62.41

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
14
10
16

cUL Listed

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

50 Hz/60 Hz

Order information
DIY Pack

IP Pack

RoHS Compliant

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.71
0.71
0.77
0.77
0.67
0.67
0.75
0.75
0.66
0.66
0.74
0.74
0.66
0.74
0.82

RoHS Compliant

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)

Power Factor% (>=)
99
96
98
92
99
95
98
92
99
95
98
92
95
99
98
0.82

UL Class P

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

ANSI – C62.41

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
15
10
10
15

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

UltraStart® T8 Programmed Start
3 – F32T8 120V-277V Ultra Low Watt .60 BF <10% THD

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
Ultra low
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – LFL PS3 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Red/White
Yellow

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
29672

Ballast Efficacy Factor
1.02
1.04
1.48
1.48
1.06
1.08
1.56
1.56
1.13
1.13
1.64
1.64
1.13
1.37
2.00

FCC – CLASS A Non-Consumer

29672 – GE-332-MVPS-XL

Pallet Pack
29666

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)

Specifications by lamp and wattage
Lamp
Nom. Line Current
0.72 A
0.30 A
0.54 A
0.24 A
0.66 A
0.28 A
0.51 A
0.22 A
0.61 A
0.26 A
0.47 A
0.21 A

UL Type 1 Outdoor

System Ballast Factor
0.89
0.89
0.98
0.98
0.86
0.86
0.96
0.96
0.84
0.84
0.93
0.93

ANSI – C62.41

Ballast Efficacy Factor
1.03
1.05
1.48
1.50
1.07
1.08
1.57
1.57
1.15
1.16
1.63
1.63

UL Type HL

Power Factor% (>=)
99
97
98
95
99
97
98
95
99
97
98
95

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16

UL Listed

# of Lamps
Line Volts
3
120
3
277
2
277
F32T8
2
120
3
120
3
277
2
120
F32T8/WM
2
277
3
120
3
277
2
120
F28T8
2
277
3
120
3
277
2
120
F25T8
2
277
Other compatible lamps: F17T8, F32T8/25W

System Watts
67
66
50
49
61
60
45
45
57
56
42
42
53
53
40
40

Safety and performance
64

Nom. Line Current
0.60 A
0.26 A
0.45 A
0.19 A
0.54 A
0.24 A
0.40 A
0.18 A
0.49 A
0.22 A
0.38 A
0.17 A
0.22 A
0.45 A
0.35 A
90.0 A

See page 195 for warranty information.

See page 195 for warranty information.

Nom. Line Current
0.58 A
0.26 A
0.21 A
0.42 A
0.53 A
0.24 A
0.04 A
0.18 A
0.49 A
0.22 A
0.35 A
0.17 A
0.45 A
0.21 A
0.35 A
0.16 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.60
0.60
0.64
0.64
0.59
0.59

Ballast Efficacy Factor
0.89
0.90
1.28
1.30
0.96
0.98

0.64
0.58
0.58

1.42
1.01
1.03

0.63
0.60
0.60
0.64
0.64

1.50
1.13
1.13
1.60
1.60

RoHS Compliant

FCC – CLASS A Non-Consumer

Power Factor% (>=)
98
93
92
98
99
94
98
92
99
94
98
91
98
92
98
89

ANSI – C62.41

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
13
10
14

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

65

HID Electromagnetic
Ballasts

Safety and performance

System Watts
69
68
52
52
63
62
48
48
58
58
45
45
58
54
41
0.158

HID Electronic
Ballasts

# of Lamps
Line Volts
System Watts
3
120
86
3
277
84
2
120
66
F32T8
2
277
65
3
120
80
3
277
79
2
120
61
F32T8/WM
2
277
61
3
120
73
3
277
72
2
120
57
F28T8
2
277
57
Other compatible lamps: F17T8, F25T8, F32T8/25W

# of Lamps
Line Volts
3
120
3
277
2
120
F32T8
2
277
3
120
3
277
2
120
F32T8/WM
2
277
3
120
3
277
2
120
F28T8
2
277
3
277
3
120
2
120
F25T8
2
277
Other compatible lamps: F17T8, F32T8/25W

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

IP Pack

General characteristics

Wiring diagram – LFL PS3 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Red/White
Yellow

Electrical characteristics

Pallet Pack
96718

DIY Pack

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)

Compact Fluorescent
Ballasts

Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
104°F (40°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, TCLP compliant,
Thermally protected, Universal voltage

Lamp

Safety and performance

UL Listed

Dimensions

Supply Current Frequency (MIN)

Pallet Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)

Sign
Ballasts

UltraStart® T8 Programmed Start

10 Pack
96715

Power Factor% (>=)
98
96
98
94
99
96
98
95
99
96
94
98
98
96
98
93

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Anti-striation control for better light quality, with no striations
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Parallel lamp operation means system maintenance is easier to manage
• Starting time visually the same as instant start

96715 – GE332-MVPS-N

Additional Info

50 Hz/60 Hz

Wiring diagram – LFL PS3 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Red/White
Yellow

Specifications by lamp and wattage
Nom. Line Current
0.95 A
0.41 A
0.70 A
0.32 A
0.88 A
0.39 A
0.64 A
0.30 A
0.79 A
0.35 A
0.27 A
0.58 A
0.74 A
0.33 A
0.56 A
0.26 A

UL Type 1 Outdoor

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating

Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
104°F (40°C)
70°C (158°F)
Low
Active
A (20-24 decibels)
Anti-striation control, Thermally protected, Universal voltage

T12
Fluorescent Ballasts

# of Lamps
Line Volts
3
120
3
277
2
120
F32T8
2
277
3
120
3
277
2
120
F32T8/WM
2
277
3
120
3
277
2
277
F28T8
2
120
3
120
3
277
2
120
F25T8
2
277
Other compatible lamps: F17T8, F32T8/25W

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

3 – F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

General characteristics

Wiring diagram – LFL PS3 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Red/White
Yellow

Electrical characteristics
Supply Current Frequency

UltraStart® T8 Programmed Start

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Anti-striation control for better light quality, with no striations.
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Multi-voltage technology handles voltage from 120 to 277V
• Parallel lamp operation means system maintenance is easier to manage

96721 – GE332-MVPS-L

T8
Fluorescent Ballasts

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

29676 – GE-332-MVPS-H

10 Pack
29676

UltraStart® T8 Programmed Start
T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps

Quick Reference
Guides

gelighting.com

UltraStart® T8 Programmed Start
T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
UltraStart® T8 Programmed Start
®

4 – F32T8 120V Normal Light .87 BF <10% THD UltraStart

General characteristics

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
Pallet Pack
29635

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)

Safety and performance

System Watts
112
92
106
87
96
79
87
73
61
51

Electronic – Programmed / Rapid Start
Rapid start
Parallel
10%
104°F (40°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Thermally protected, Universal voltage

Electrical characteristics
Supply Current Frequency (MIN)

50 Hz/ 60 Hz

Order information
10 Pack
96716

Pallet Pack
96719

UL Type 1 Outdoor

System Ballast Factor
0.89
0.96
0.87
0.94
0.84
0.91
0.88
0.95
0.89
0.96
UL Type HL

Ballast Efficacy Factor
0.79
1.04
0.82
1.08
0.87
1.15
1.01
1.30
1.45
1.88

ANSI – C62.41

Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
50 / 10
0 / -18

UL Listed

Lamp

# of Lamps
Line Volts
System Watts
4
120
114
4
277
112
3
120
93
F32T8
3
277
92
4
120
105
4
277
103
3
120
86
F32T8/WM
3
277
85
4
120
96
4
277
95
3
120
79
F28T8
3
277
78
Other compatible lamps: F17T8, F25T8, F32T8/25W

Safety and performance

UltraStart® T8 Programmed Start
®

4 – F32T8 277V Normal Light .87 BF <10% THD UltraStart

General characteristics

Dimensions

Order information
Pallet Pack
29650

DIY Pack

IP Pack

RoHS Compliant

Nom. Line Current
0.42 A
0.35 A
0.39 A
0.32 A
0.35 A
0.29 A
0.33 A
0.28 A
0.24 A
0.20 A
UL Type 1 Outdoor

System Ballast Factor
0.89
0.96
0.86
0.94
0.84
0.91
0.88
0.95
0.88
0.95
ANSI – C62.41

Ballast Efficacy Factor
0.79
1.03
0.83
1.10
0.90
1.18
1.00
1.31
1.41
1.86

UL Type HL

FCC – CLASS A Non-Consumer

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)

4 – F32T8 120V-277V Low Watts .71 BF <10% THD UltraStart®

Power Factor% (>=)
99
98
98
98
98
98
97
98
97
96

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
11

Wiring diagram – LFL PS4 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Blue/White
Red/White
Yellow
Yellow

Electrical characteristics
50 Hz
50 Hz/60 Hz

Order information

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

See page 195 for warranty information.

UL Class P

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16

UL Listed

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
104°F (40°C)
70°C (158°F)
Low – PS
Active
A (20-24 decibels)
Anti-striation control, Thermally protected, Universal voltage

Supply Current Frequency
Supply Current Frequency (MIN)

10 Pack
71832

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Anti-striation control for better light quality, with no striations
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Multi-voltage technology handles voltage from 120 to 277V
• Parallel lamp operation means system maintenance is easier to manage

UltraStart® T8 Programmed Start

Pallet Pack

DIY Pack

IP Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)
8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)
48 in (1219 mm)

Specifications by lamp and wattage
Lamp

# of Lamps
Line Volts
System Watts
4
120
90
4
277
88
3
120
72
F32T8
3
277
71
4
120
85
4
277
83
3
120
68
F32T8/WM
3
277
67
4
120
77
4
277
76
3
120
63
F28T8
3
277
63
Other compatible lamps: F17T8, F25T8, F32T8/25W

Safety and performance
66

ANSI – C62.41

Power Factor% (>=)
99
97
98
95
99
97
98
95
99
97
98
95

RoHS Compliant

See page 195 for warranty information.

Nom. Line Current
0.39 A
0.32 A
0.68 A
0.78 A
0.71 A
0.30 A
0.58 A
0.26 A
0.64 A
0.28 A
0.53 A
0.23 A
UL Type 1 Outdoor

System Ballast Factor
0.71
0.71
0.58
0.58
0.69
0.69
0.57
0.57
0.68
0.68
0.55
0.55
ANSI – C62.41

Ballast Efficacy Factor
0.78
0.80
0.81
0.82
0.81
0.83
0.84
0.85
0.88
0.89
0.88
0.88

UL Type HL

Power Factor% (>=)
1
1
1
1
1
1
1
1
1
1
1
1

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16

UL Listed

67

HID Electromagnetic
Ballasts

Safety and performance

System Watts
112
93
103
85
93
77
88
72
62
51

Ballast Efficacy Factor
0.78
0.79
1.03
1.04
0.81
0.83
1.09
1.10
0.86
0.87
1.16
1.17

HID Electronic
Ballasts

# of Lamps
Line Volts
4
277
F32T8
3
277
4
277
F32T8/WM
3
277
4
277
F28T8
3
277
4
277
F25T8
3
277
4
277
F17T8
3
277
Other compatible lamps: F32T8/25W

UL Type HL

71832 – GE432-MVPS-L

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

UL Type 1 Outdoor

System Ballast Factor
0.89
0.89
0.96
0.96
0.86
0.86
0.94
0.94
0.83
0.83
0.92
0.92

General characteristics

Wiring diagram – LFL PS4 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Blue/White
Red/White
Yellow

50 Hz/60 Hz

RoHS Compliant

Nom. Line Current
0.97 A
0.41 A
0.78 A
0.34 A
0.88 A
0.37 A
0.72 A
0.31 A
0.81 A
0.35 A
0.66 A
0.29 A

Compact Fluorescent
Ballasts

Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics

10 Pack
29627

IP Pack

8.8 in (225.80 mm)
1.1 in (28.70 mm)
0.3 in (7.92 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)

Sign
Ballasts

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

29627 – GE-432-277-PS-N

Supply Current Frequency

DIY Pack

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.18 in (30.00 mm)

Specifications by lamp and wattage
Nom. Line Current
0.95 A
0.79 A
0.92 A
0.75 A
0.83 A
0.68 A
0.75 A
0.63 A
0.53 A
0.44 A

RoHS Compliant

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagram – LFL PS4 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Blue/White
Red/White
Yellow

T12
Fluorescent Ballasts

# of Lamps
Line Volts
4
120
F32T8
3
120
4
120
F32T8/WM
3
120
4
120
F28T8
3
120
4
120
F25T8
3
120
4
120
F17T8
3
120
Other compatible lamps: F32T8/25W

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

4 F32T8 120V-277V Normal Light .88 BF <10% THD UltraStart®

General characteristics

Wiring diagram – LFL PS4 – see example on page 73
Case dimensions – Ref Drawing -A – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Blue/White
Red/White
Yellow

Electrical characteristics
Supply Current Frequency

UltraStart® T8 Programmed Start

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Anti-striation control for better light quality, with no striations
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Multi-voltage technology handles voltage from 120 to 277V
• Parallel lamp operation means system maintenance is easier to manage

96716 – GE432-MVPS-N

T8
Fluorescent Ballasts

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

29625 – GE-432-120-PS-N

10 Pack
29625

UltraStart® T8 Programmed Start
T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps

Quick Reference
Guides

gelighting.com

UltraStart® T8 Programmed Start
T8 Programmed Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
UltraStart® T8 Programmed Start
4 – F32T8 120V-277V High Light 1.15 BF <10% THD UltraStart®

General characteristics

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
70°C (158°F)
High
Active
A (20-24 decibels)
Auto-restart, Thermally protected

50 Hz/60 Hz

Order information
Pallet Pack
29657

DIY Pack

IP Pack

11.75 in (298.45 mm)
2.4 in (60.96 mm)
1.6 in (41.91 mm)
11.1 in (282.97 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
3.10 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
33 in (838 mm)
33 in (838 mm)
48 in (1219 mm)

RoHS Compliant

Nom. Line Current
1.27 A
0.55 A
1.03 A
0.45 A
1.20 A
0.52 A
0.95 A
0.43 A
1.08 A
0.47 A
0.86 A
0.39 A
1.00 A
0.44 A
0.83 A
0.37 A
0.69 A
0.31 A
0.58 A
0.26 A
ANSI – C62.41

System Ballast Factor
1.16
1.16
1.26
1.26
1.15
1.15

Ballast Efficacy Factor
0.78
0.80
1.05
1.05
0.82
0.84

1.24
1.12
1.12

1.10
0.89
0.91

1.21
1.15
1.15
1.23
1.23
1.15
1.15
1.23
1.23

1.19
0.98
1.00
1.26
1.28
1.41
1.43
1.83
1.83

UL Type 1 Outdoor

UL Type HL

Power Factor% (>=)
98
96
98
96
97
97
98
97
97
97
98
97
98
96
98
96
98
95
98
95

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

cUL Listed

THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
16
10
15
10
16
10
15

Wiring diagram – LFL 18b – see example on page 74
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
Gray and Violet
White and Black

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
80353

Pallet Pack

DIY Pack

IP Pack

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)
8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.30 lbs
Side
12 ft
18 AWG
Length (± 1 in)
51 in (1295 mm)
33 in (838 mm)
25 in (635 mm)

Specifications by lamp and wattage
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

Lamp
F32T8
F25T8

# of Lamps
1
1

Line Volts
120
120

System Watts
32
26

Safety and performance

Nom. Line Current
0.26 A
0.21 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.88
0.90

Ballast Efficacy Factor
2.75
3.46

FCC – CLASS A Non-Consumer

UL Listed

Crest Factor (<=)
1.6
1.6

THD% (<=)
10
10

Min. Starting Temp (°F/°C)
50 / 10
50 / 10

CSA

• Integrate dimming ballasts with daylight harvesting for significant energy savings
• Greater control of workspace lighting, ability to create a mood, energy savings
• Designed to ensure optimum lamp performance with lamp current crest factor below the
1.7 ANSI standard
• Start lamps according to ANSI recommendations throughout the entire dimming range

80355 – B232SR120V5
T8 Dimming Ballasts
2 – F32T8 DIM 100 to 5% RS 120

General characteristics

Dimensions
Electronic – Dimming
Rapid start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – LFL 19 – see example on page 74
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
Gray and Violet
White and Black
Yellow

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Pallet Pack

DIY Pack

IP Pack

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)

Compact Fluorescent
Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

10 Pack
80355

UL Class P

Power Factor% (>=)
99
99

Sign
Ballasts

Safety and performance

System Watts
147
144
120
120
139
136
114
112
125
123
103
101
117
115
97
96
81
80
67
67

Electronic – Dimming
Rapid start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

T12
Fluorescent Ballasts

# of Lamps
Line Volts
4
120
4
277
3
120
F32T8
3
277
4
120
4
277
3
120
F32T8/WM
3
277
4
120
4
277
3
120
F28T8
3
277
4
120
4
277
3
120
F25T8
3
277
4
120
4
277
3
120
F17T8
3
277
Other compatible lamps: F32T8/25W

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp

1 – F32T8 DIM 100 to 5% RS 120

General characteristics

Wiring diagram – LFL PS4 – see example on page 73
Case dimensions – Ref Drawing LG – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Blue/White
Red/White
Yellow

Electrical characteristics
Supply Current Frequency

T8 Dimming Ballasts

8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.30 lbs
Side
12 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
33 in (838 mm)
25 in (635 mm)
51 in (1295 mm)

# of Lamps
2

Line Volts
120

System Watts
62

Safety and performance

See page 195 for warranty information.

See page 195 for warranty information.

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.88

Ballast Efficacy Factor
1.41

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
UL Listed

Crest Factor (<=)
1.6

THD% (<=)
10

Min. Starting Temp (°F/°C)
50 / 10

CSA

69

HID Electromagnetic
Ballasts

68

Nom. Line Current
0.52 A

HID Electronic
Ballasts

Specifications by lamp and wattage
Lamp
F32T8

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• Integrate dimming ballasts with daylight harvesting for significant energy savings
• Greater control of workspace lighting, ability to create a mood, energy savings
• Designed to ensure optimum lamp performance with lamp current crest factor below the
1.7 ANSI standard
• Start lamps according to ANSI recommendations throughout the entire dimming range

80353 – B132R120V5

T8
Fluorescent Ballasts

• A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency)
• Extends lamp life in frequently switched applications (> 100,000 on/off cycles)
• Starting time visually the same as instant start
• Multi-voltage technology handles voltage from 120 to 277V (H and XL series)
• Parallel lamp operation means system maintenance is easier to manage

29678 – GE-432-MVPS-H

10 Pack
29678

T8 Dimming
T8 Dimming Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps

Quick Reference
Guides

gelighting.com

T8 Dimming
T8 Dimming Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
T8 Dimming Ballasts
2 – F32T8 Switch 100/50% RS 277

General characteristics

Dimensions
Electronic – Dimming
Rapid start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

60 Hz

Order information
Pallet Pack

DIY Pack

IP Pack

# of Lamps
2
2

Line Volts
277
277

System Watts
62
48

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)
8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.30 lbs
Side
12 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
25 in (635 mm)

UL Type 1 Outdoor

System Ballast Factor
0.88
0.88

Canadian Energy Standards

Ballast Efficacy Factor
1.41
1.83

UL Type HL

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.7

UL Class P

UL Listed

THD% (<=)
10
10

2 – F32T8 DIM 100 to 5% RS 277

General characteristics

Order information
10 Pack
80357

Min. Starting Temp (°F/°C)
50 / 10
50 / 10

60 Hz

Order information
Pallet Pack

DIY Pack

IP Pack

Line Volts
277

Safety and performance

Nom. Line Current
0.22 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.88

Ballast Efficacy Factor
1.41

FCC – CLASS A Non-Consumer

UL Class P

Line Volts
120

System Watts
92

Nom. Line Current
0.77 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.88

Ballast Efficacy Factor
0.95

FCC – CLASS A Non-Consumer

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)
8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.30 lbs
Side
12 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
33 in (838 mm)
25 in (635 mm)
51 in (1295 mm)

Power Factor% (>=)

UL Listed

Crest Factor (<=)
1.6

THD% (<=)
10

T8 Dimming Ballasts
3 – F32T8 DIM 100 to 5% RS 277

60 Hz

Order information
Pallet Pack

DIY Pack

IP Pack

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)
8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.30 lbs
Side
12 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
36 in (914 mm)
36 in (914 mm)
25 in (635 mm)
36 in (914 mm)

Specifications by lamp and wattage
Lamp
F32T8

# of Lamps
3

Line Volts
277

System Watts
92

Safety and performance

See page 195 for warranty information.

Min. Starting Temp (°F/°C)
50 / 10

CSA

Wiring diagram – LFL 20 – see example on page 74
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Gray and Violet
Blue and Red
Red/White
White and Black
Yellow

Electrical characteristics

CSA

THD% (<=)
10

Dimensions
Electronic – Dimming
Rapid start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Supply Current Frequency

Min. Starting Temp (°F/°C)
50 / 10

UL Listed

Crest Factor (<=)
1.5

• Integrate dimming ballasts with daylight harvesting for significant energy savings
• Greater control of workspace lighting, ability to create a mood, energy savings
• Designed to ensure optimum lamp performance with lamp current crest factor below the
1.7 ANSI standard
• Start lamps according to ANSI recommendations throughout the entire dimming range

80358 – B332SR277V5

10 Pack
80358

UL Class P

Power Factor% (>=)
99

See page 195 for warranty information.

Nom. Line Current
0.33 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.88

Ballast Efficacy Factor
0.95

FCC – CLASS A Non-Consumer

UL Class P

Power Factor% (>=)
99
UL Listed

Crest Factor (<=)
1.5

THD% (<=)
10

Min. Starting Temp (°F/°C)
50 / 10

CSA

71

HID Electromagnetic
Ballasts

70

System Watts
62

# of Lamps
3

HID Electronic
Ballasts

# of Lamps
2

Specifications by lamp and wattage
Lamp
F32T8

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp
F32T8

IP Pack

General characteristics

Wiring diagram – LFL 19 – see example on page 74
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
Gray and Violet
White and Black
Yellow

Electrical characteristics
Supply Current Frequency

DIY Pack

8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.30 lbs
Side
12 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
36 in (914 mm)
36 in (914 mm)
25 in (635 mm)
36 in (914 mm)

Compact Fluorescent
Ballasts

Electronic – Dimming
Rapid start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Pallet Pack

Safety and performance

CSA

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

60 Hz

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)

Sign
Ballasts

T8 Dimming Ballasts

Wiring diagram – LFL 20 – see example on page 74
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Gray and Violet
Blue and Red
Red/White
White and Black
Yellow

Electrical characteristics
Supply Current Frequency

• Integrate dimming ballasts with daylight harvesting for significant energy savings
• Greater control of workspace lighting, ability to create a mood, energy savings
• Designed to ensure optimum lamp performance with lamp current crest factor below the
1.7 ANSI standard
• Start lamps according to ANSI recommendations throughout the entire dimming range

80356 – B232SR277V5

10 Pack
80356

Power Factor% (>=)
99
99

Electronic – Dimming
Rapid start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

T12
Fluorescent Ballasts

Safety and performance

Nom. Line Current
0.23 A
0.18 A

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp
F32T8
F25T8

3 – F32T8 DIM 100 to 5% RS 120

General characteristics

Wiring diagram – LFL 16 – see example on page 74
Case dimensions – Ref Drawing ST – see page 75
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Black/White

Electrical characteristics
Supply Current Frequency

T8 Dimming Ballasts

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• Integrate dimming ballasts with daylight harvesting for significant energy savings
• Greater control of workspace lighting, ability to create a mood, energy savings
• Designed to ensure optimum lamp performance with lamp current crest factor below the
1.7 ANSI standard
• Start lamps according to ANSI recommendations throughout the entire dimming range

80357 – B332SR120V5

T8
Fluorescent Ballasts

• Integrate dimming ballasts with daylight harvesting for significant energy savings
• Greater control of workspace lighting, ability to create a mood, energy savings
• Designed to ensure optimum lamp performance with lamp current crest factor below the
1.7 ANSI standard
• Start lamps according to ANSI recommendations throughout the entire dimming range

80362 – B232SR277S50

10 Pack
80362

T8 Dimming
T8 Dimming Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps

Quick Reference
Guides

gelighting.com

Wiring Diagrams
T8 Fluorescent Ballasts

Wiring Diagrams
T8 Fluorescent Ballasts
LFL 1B

LFL 4a

LFL PS2

LFL 1C

LFL 1D

LFL PS3

LFL PS4

T8
Fluorescent Ballasts

LFL 1A

T5
Fluorescent Ballasts
T12
Fluorescent Ballasts
Sign
Ballasts
Compact Fluorescent
Ballasts
HID Electronic
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

73

HID Electromagnetic
Ballasts

72

Quick Reference
Guides

gelighting.com

Wiring Diagrams
T8 Fluorescent Ballasts
LFL 18b

Case Dimensions
T8 Fluorescent Ballasts
LFL 19

-A
T8
Fluorescent Ballasts
T5
Fluorescent Ballasts

ST

T12
Fluorescent Ballasts

LFL 16

LFL 20

Sign
Ballasts

LG
Compact Fluorescent
Ballasts
HID Electronic
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

75

HID Electromagnetic
Ballasts

74

T5 High Efficiency – Programmed Start
T5 Electronic Programmed Start For F14 (2 ft), F21 (3 ft), F28 (4 ft), F35 (5 ft) HE T5 Lamps*
99653 – GE228MVPSH-A
2 or 1 – F14-F28T5HE, 120 to 277 UltraStart® PRS High Light 1.15 BF A Can

General characteristics

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating

Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
104°F (40°C)
90°C (194°F)
High (1.15)
Active
A (20-24 decibels)
Auto-restart, End-of-Life Protection (EOL), Thermally protected,
Universal voltage, Anti-striation control

Additional Info

Electrical characteristics
Supply Current Frequency

UltraStart® T5 programmed start ballasts for T5 fluorescent lamps.

The GE UltraStart® Watt-Miser® T5 Lamp and Ballast System Advantage
• 18 watts lower than standard 4-lamp, 54 watt T5 systems with the same light output
• Operates lamps in parallel (which means if one lamp fails, the other lamps remain on)
– significantly reduces lamp maintenance costs
• Fast starting programmed start ballast < 700 milliseconds compared to standard
T5 at > 1.1 to 1.5 seconds

Order information
10 Pack
99653

Pallet Pack
99654

DIY Pack

# of Lamps
Line Volts
System Watts
Nom. Line Current
2
120
72
0.60 A
2
277
70
0.25 A
1
120
45
0.37 A
F28T5/HE
1
277
45
0.17 A
2
120
68
0.57 A
F28T5/WM
2
277
67
0.25 A
2
120
57
0.47 A
2
277
56
0.21 A
1
120
36
0.30 A
1
277
36
0.14 A
F21T5/HE
1
120
43
0.36 A
F28T5WM
1
277
43
0.17 A
Other compatible lamps: F28T5/WM, F14T5/HE, F14T5/WM, F21T5/WM, F28T5/HL
UL Type CC
RoHS Compliant

High Efficiency (HE) Lamps (F14T5, F21T5, F28T5, F35T5 – standard, high-lumen
and Watt-Miser®)
These lamps are high efficiency (HE), delivering around 100 lumens per watt and, while
operating at the same lamp arc current, can be operated on the same ballast if the ballast
system power and starting voltage are appropriate for the lamp load.

UL Type 1 Outdoor

System Ballast Factor
1.16
1.16
1.36
1.36

UL Listed

UL Type HL

Power Factor % (>=)
99
97
99
93
99
96
99
95
99
90
99
92

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.65
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

cUL Listed

THD (<=)
10
9
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15

Meets ANSI Standard C62.41-1991

Meets ANSI Standard C82.11- cons 2002

99655 – GE228MVPS-A
T5 High Efficiency - UltraStart® Programmed Start
2 or 1 – F14-F35T5HE, 120 – 277 UltraStart® PRS Normal Light - .95 BF A Can

General characteristics

• High Efficiency T5 ballast with Continuous Cathode Cutout Technology
• Lower Maintenance Costs with Parallel Lamp Operation
• Fast Starting Time <700ms
• Multi-Voltage technology means a single ballast handles voltage from 108V to 305V
• Auto-Restart withstands temporary losses in power without the need to cycle power
• UltraCool™ Operation 90C case rating

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating

Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
104°F (40°C)
90°C (194°F)
Normal
Active
A (20-24 decibels)
Auto-restart, End-of-Life Protection (EOL), Thermally protected,
Universal voltage, Anti-striation control

Additional Info

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Pallet Pack
99656

DIY Pack

Wiring diagram – LFL 4a – see example on page 82
Case dimensions – Ref Drawing -A Can – see page 83
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Green
Yellow

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.2 in (30.48 mm)
8.9 in (226.06 mm)
0.3 in (6.35 mm)
1.49 lbs
Side
8 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
34 in (864 mm)
3.5 in (89 mm)
45 in (1143 mm)

IP Pack

®

High Output (HO) Lamps (F24T5, F39T5, F54T5, F49T5, F80T5 – standard and Watt-Miser )
These lamps are driven for high light output and are slightly less efficient (LPW) than HE lamps.
They have unique lamp arc currents and starting voltages by wattage that require a specific
ballast for each HO lamp wattage.

Specifications by lamp and wattage
Lamp

Safety and performance

UL Type CC

UL Type 1 Outdoor

UL Listed

Ballast Efficacy Factor

UL Type HL

1.60
1.63
2.87
2.87
1.67
1.67

Power Factor % (>=)
99
97
99
93
99
96
99
91
99
95
99
90

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

cUL Listed

THD (<=)
10
9
10
10
10
9
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15

Meets ANSI Standard C62.41-1991

RoHS Compliant Meets ANSI Standard C82.11- cons 2002

76

See T8 ballast section (page 37) for nomenclature information.

See page 195 for warranty information.

*T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length.

77

HID Electromagnetic
Ballasts

# of Lamps
Line Volts
System Watts
Nom. Line Current
System Ballast Factor
2
120
75
0.62 A
2
277
73
0.27 A
1
120
46
0.39 A
F35T5/HE
1
277
46
0.18 A
2
120
60
0.50 A
0.96
2
277
59
0.23 A
0.96
1
120
38
0.31 A
1.09
F28T5/HE
1
277
38
0.15 A
1.09
2
120
57
0.48 A
0.95
2
277
57
0.21 A
0.95
1
120
36
0.30 A
F28T5/WM
1
277
36
0.15 A
Other compatible lamps: F21T5/HE, F21T5/WM, F14T5/HE, F14T5/WM, F35T5/WM, F28T5/HL

HID Electronic
Ballasts

10 Pack
99655

Ballast Efficacy Factor
1.61
1.66
3.02
3.02

Compact Fluorescent
Ballasts

GE T5 lamps can be electrically characterized into two groups:

IP Pack

Sign
Ballasts

T5 Lamps

8.9 in (226.06 mm)
0.3 in (6.35 mm)
1.49 lbs
Side
8 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
34 in (864 mm)
3.5 in (89 mm)
45 in (1143 mm)

Specifications by lamp and wattage
Lamp

Safety and performance

GE UltraStart® T5 programmed start ballasts use a control circuit to apply very precise
cathode heat to ensure lamp cathodes have reached optimum temperature during lamp
starting. Precise starting reduces the amount of cathode degradation associated with
each start and increases lamp life significantly. After starting the lamps, continuous cathode
cutout technology (CCC) is applied—which eliminates wasted power to the lamps, resulting
in high efficiencies. GE UltraStart® systems also have the advantage of operating lamps in
parallel. Parallel (versus series) lamp operation ballasts typically reduce spot relamping costs by
50% or extend group relamping by 15% or more due to average lamp mortality early failures.

9.5 in (241.30 mm)
1.7 in (43.18 mm)
1.2 in (30.48 mm)

T12
Fluorescent Ballasts

GE has developed a line of T5 ballasts that incorporate the benefits of programmed start
ballasts with the energy savings, fast starting and parallel lamp operation of instant start
ballasts. GE’s UltraStart® T5 ballasts use low energy loss, high efficiency components along
with continuous cathode cutout (CCC) technology—resulting in 8 fewer watts than standard
4-lamp 54 watt T5 ballasts. GE’s UltraStart® T5 ballasts offer a 44% improvement over
standard T5 ballasts and create a new industry threshold for high efficiency ballasts.

60 Hz

Wiring diagram – LFL 4a – see example on page 82
Case dimensions – Ref Drawing -A Can – see page 83
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Green
Yellow

T5
Fluorescent Ballasts

Understanding T5
Electronic Programmed Start Ballasts

T8
Fluorescent Ballasts

T5 High Efficiency - UltraStart® Programmed Start

• High Efficiency T5 ballast with Continuous Cathode Cutout Technology
• Lower Maintenance Costs with Parallel Lamp Operation
• Fast Starting Time <700ms
• Multi-Voltage technology means a single ballast handles voltage from 108V to 305V
• Auto-Restart withstands temporary losses in power without the need to cycle power
• UltraCool™ Operation 90C case rating

Quick Reference
Guides

gelighting.com

T5 High Efficiency – Programmed Start
T5 Electronic Programmed Start For F14 (2 ft), F21 (3 ft), F28 (4 ft), F35 (5 ft) HE T5 Lamps*

T5 High Output - Programmed Start
2 – F24T5HO PRS UNV 50/60 Hz C Can

2 – F28T5 PRS UNV 50/60 Hz, C Can

General characteristics

General characteristics

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating

Wiring diagram – LFL 4b – see example on page 82
Case dimensions – Ref Drawing -C Can – see page 83
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge

14.25 in (361.95 mm)
1.2 in (29.97 mm)
1.0 in (25.40 mm)
13.75 in (349.25 mm)
0.25 in (6.35 mm)
1.00 lb
Poke-in
18 ft
18 AWG

F28T5/HE
F21T5/HE

F14T5/HE

13.8 in (349.25 mm)
0.25 in (6.35 mm)
1.0 lb
Poke-in
18 ft
18 AWG

50 Hz/60 Hz

DIY Pack

10 Pack
47534

IP Pack

Line Volts
120
277
120
277
120
277
120
277
120
277
120
120
277
120
277

Safety and performance

System Watts
81
78
40
40
66
64
33
33
49
48
25
34
34
18
18

Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage
Nom. Line Current
0.67 A
0.28 A
0.34 A
0.15 A
0.55 A
0.23 A
0.28 A
0.12 A
0.41 A
0.17 A
0.21 A
0.28 A
0.12 A
0.15 A
0.07 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.98
0.98
0.98
0.95
0.98
0.98
0.98
0.95
0.98
0.98
0.98
0.98
0.95
0.98
0.95

Ballast Efficacy Factor
1.20
1.25
2.45
2.37
1.48
1.53
2.96
2.87
2.00
2.04
3.92
2.88
2.79
5.44
5.27

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=)

CSA

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
10
15

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

Lamp

# of Lamps
Line Volts
2
120
2
277
1
120
F24T5/HO
1
277
2
120
2
277
1
120
FT24W/4P
1
277
2
120
2
277
1
120
FT24W/2G10
1
277
1
120
F39T5/HO
1
277
1
120
FT36W/4P
1
277
Other compatible lamps: F36W/2G10

System Watts
53
52
28
28
52
51
27
27
48
47
24
24
41
40
36
36

Safety and performance

Nom. Line Current
0.45 A
0.19 A
0.23 A
0.10 A
0.43 A
0.18 A
0.22 A
0.10 A
0.40 A
0.17 A
0.20 A
0.09 A
0.34 A
0.15 A
0.30 A
0.13 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.98
0.98
0.98
0.95
0.98
0.98
0.98
0.95
0.98
0.98
0.98
0.95
0.98
0.98
0.98
0.95

Ballast Efficacy Factor
1.84
1.88
3.50
3.39
1.88
1.92
3.62
3.51
2.04
2.08
4.08
3.95
2.39
2.45
2.72
2.63

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=)

95
95
95
95
CSA

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD (<=)
10
10
10
10
10
10
10
15
10
10
10
15
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

Sign
Ballasts

• Electronic ballasts for all general fluorescent applications
• Extends lamp life in frequently switched applications
• Reduced lamp replacement cost; ideal for use with occupancy sensors

47540 – B239PUNV-DOG1C
T5 High Output - Programmed Start

T12
Fluorescent Ballasts

F35T5/HE

# of Lamps
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1

14.3 in (361.95 mm)
1.2 in (29.97 mm)
1.0 in (25.40 mm)

Order information
Pallet Pack

Specifications by lamp and wattage
Lamp

Wiring diagram – LFL 4b – see example on page 82
Case dimensions – Ref Drawing -C Can – see page 83
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
10 Pack
47536

Electronic – Programmed / Rapid Start
Programmed start
Series
10%
105°F (41°C)
75°C (167°F)
Normal
Active
A (20-24 decibels)
Auto-restart, End-of-Life Protection (EOL), Thermally protected,
Universal voltage

Additional Info

Electrical characteristics
Supply Current Frequency

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating

T5
Fluorescent Ballasts

Electronic – Programmed / Rapid Start
Programmed start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, End-of-Life Protection (EOL), Thermally protected,
Universal voltage

Additional Info

T8
Fluorescent Ballasts

T5 High Efficiency - Programmed Start

• Electronic ballasts for all general fluorescent applications
• Extends lamp life in frequently switched applications
• Reduced lamp replacement cost; ideal for use with occupancy sensors

47534 – B224PUNV-COG1C

• Electronic ballasts for all general fluorescent applications
• Extends lamp life in frequently switched applications
• Reduced lamp replacement cost; ideal for use with occupancy sensors

47536 – B228PUNV-C0G1C

T5 High Output – Programmed Start
T5 Electronic Programmed Start For F24 (2 ft), F39 (3 ft), F54 (4 ft), F80 (5 ft) HO T5 Lamps*

Quick Reference
Guides

gelighting.com

2 – F39T5HO PRS UNV 50/60 Hz D Can

General characteristics

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, End-of-Life Protection (EOL), Thermally protected,
Universal voltage

Additional Info

Wiring diagrams – LFL 4b – see example on page 82
Case dimensions – Ref Drawing -D Can – see page 83
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge

16.9 in (428.75 mm)
1.2 in (29.97 mm)
1.0 in (25.40 mm)

Compact Fluorescent
Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating

16.2 in (411.48 mm)
0.25 in (6.35 mm)
Poke-in
18 ft
18 AWG

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage
Lamp

F39T5/HO

FT39W/4P

Line Volts
120
277
120
277
120
277
120
277
120
277
120
277

System Watts
89
88
47
47
71
70
38
38
59
59
32
32

Safety and performance

78

See page 195 for warranty information.

See page 195 for warranty information.

Nom. Line Current
0.74 A
0.32 A
0.39 A
0.17 A
0.59 A
0.25 A
0.31 A
0.14 A
0.51 A
0.22 A
0.26 A
0.12 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.98
0.98
0.98
0.95
0.98
0.95
0.98
0.90
0.98
0.95
0.98
0.90

Ballast Efficacy Factor
1.10
1.11
2.08
2.02
1.38
1.35
2.57
2.36
1.66
1.61
3.06
2.81

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=)

97
97

CSA

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD (<=)
10
10
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

*T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length.

79

HID Electromagnetic
Ballasts

F24T5/HO

# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1

HID Electronic
Ballasts

10 Pack
47540

T5 High Output – Programmed Start
T5 Electronic Programmed Start For F24 (2 ft), F39 (3 ft), F54 (4 ft), F80 (5 ft) HO T5 Lamps*
T5 High Output - UltraStart® Programmed Start
®

2 or 1 – F54T5HO 120 to 277V UltraStart PRS High Temp F Can

General characteristics

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

60 Hz

Order information
10 Pack
99651

Pallet Pack
99652

DIY Pack

General characteristics

Electrical characteristics
Supply Current Frequency

Safety and performance

60 Hz

Order information

IP Pack

10 Pack
99649

Pallet Pack
99650

UL Type 1 Outdoor

UL Type CC

System Ballast Factor

Ballast Efficacy Factor

0.98
0.98
0.95
1.00
1.00

1.53
2.96
2.87
0.86
0.87

1.00
1.00
1.12
1.12

0.92
0.93
1.70
1.70

UL Listed

UL Type HL

Power Factor % (>=)
99
98
99
97
99
98
99
97
99
97
99
97

Meets ANSI Standard C62.41-1991

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.68
1.68
1.7
1.7
1.7
1.7
1.7
1.7

UL Class P

THD (<=)
1
1
10
1
4.6
7.9
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15

Meets ANSI Standard C82.11- cons 2002 RoHS Compliant

Lamp

# of Lamps
Line Volts
System Watts
Nom. Line Current
4
277
216
0.79 A
3
277
174
0.66 A
2
277
117
0.48 A
1
277
77
0.34 A
4
120
220
1.84 A
3
120
177
1.48 A
2
120
118
0.99 A
F54T5WM
1
120
77
0.64 A
4
277
226
0.83 A
3
277
185
0.69 A
2
277
121
0.49 A
1
277
78
0.35 A
4
120
232
1.94 A
3
120
188
1.58 A
2
120
121
1.024 A
F54T5HO
1
120
82
0.69 A
Other compatible lamps: FT55W/4P, FT50W/4P, FT39W/4P, FC12T5HO, F58T8

Safety and performance

®

T5 High Output - UltraStart Programmed Start

Dimensions

FT55W/4P

cUL Listed

UL Type CC

Min. Starting Temp (°F/°C)
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
5 / -15
UL Listed

• Electronic ballasts for all general fluorescent applications
• Extends lamp life in frequently switched applications
• Reduced lamp replacement cost; ideal for use with occupancy sensors
• Slim profile housing

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

16.8 in (428.75 mm)
1.1 in (29.97 mm)
1.2 in (30.48 mm)
16.2 in (411.48 mm)
0.25 in (6.35 mm)
Poke-in
18 ft
18 AWG

Electronic – Programmed / Rapid Start
Programmed start
Series – parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, End-of-Life Protection (EOL), Thermally protected

Electrical characteristics
Supply Current Frequency

Wiring diagrams – LFL 62-1, LFL 62-2, LFL 62-3 – see example on page 82
Case dimensions – Ref Drawing -J – see page 83
Length (L)
24 in (609.60 mm)
Width (W)
1.2 in (31.49 mm)
Height (H)
1.1 in (29.97 mm)
Mounting dimensions
Mount Length (M)
23.5 in (597.99 mm)
Mount Slots (MS)
0.3 in (7.92 mm)
Weight
1.78 lbs
Exit Type
Poke-in
Remote Mounting Distance to Lamp
18 ft
Remote Mounting Wire Gauge
18 AWG

50 Hz/60 Hz

50 Hz/60 Hz

Order information
Pallet Pack

Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
120

Safety and performance
80

UL Class P

THD (<=)
7
9
11
16
6
7
10
13
7
8
12
14
6
8
9
12

DIY Pack

10 Pack
29726

IP Pack

System Watts
120
117
63
62
106
103
56
56
90
88
44
44
60
60

Pallet Pack
29717

DIY Pack

IP Pack

Specifications by lamp and wattage
Lamp
Nom. Line Current
1.03 A
0.43 A
0.52 A
0.23 A
0.88 A
0.38 A
0.46 A
0.21 A
0.75 A
0.32 A
0.37 A
0.17 A
0.50 A
0.48 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
1.00
1.00
1.02
1.02
0.85
0.85
0.87
0.87
1.20
1.20
1.22
1.22
1.12
0.92

Ballast Efficacy Factor
0.83
0.85
1.61
1.64
0.80
0.82
1.55
1.55
1.33
1.36
2.77
2.77
1.86
1.53

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=)
99
98
99
95
99
98
99
95
99
98
99
90
99
99
UL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

Line Volts
120
277
120
277
120
277
277
120

System Watts
238
233
185
182
122
120
65
64

Safety and performance

RoHS Compliant

F54T5/HO

# of Lamps
4
4
3
3
2
2
1
1

Nom. Line Current
2.00 A
0.86 A
1.52 A
0.66 A
0.99 A
0.43 A
0.24 A
0.52 A
UL Type 1 Outdoor

System Ballast Factor
1.00
1.00

UL Type CC

Ballast Efficacy Factor
0.42
0.42

ANSI – C62.41

UL Type HL

Power Factor % (>=)
99
99
99
99
99
98
95
99

Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4

FCC – CLASS A Non-Consumer

UL Class P

THD (<=)
8
8
8
8
8
12
14
12
cUL Listed

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
UL Listed

CSA

See page 195 for warranty information.

See page 195 for warranty information.

*T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length.

81

HID Electromagnetic
Ballasts

FT36W/4P

Crest Factor (<=)
1.63
1.62
1.61
1.56
1.64
1.62
1.60
1.55
1.64
1.62
1.63
1.56
1.65
1.64
1.62
1.55

HID Electronic
Ballasts

FC12T5-55W

FCC – CLASS A Non-Consumer ANSI-C62.41

General characteristics

Wiring diagram – LFL 4b – see example on page 82
Case dimensions – Ref Drawing -D Can – see page 83
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge

Specifications by lamp and wattage

F54T5/HO

Power Factor % (>=)
0.98
0.95
0.90
0.81
0.99
0.99
0.99
0.99
0.98
0.97
0.89
0.81
0.99
0.99
0.99
0.99

Compact Fluorescent
Ballasts

Electronic – Programmed / Rapid Start
Programmed start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, End-of-Life Protection (EOL), Thermally protected,
Universal voltage

Order information

# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
1
1

UL Type HL

T5 High Output - UltraStart® Programmed Start

Electrical characteristics

Lamp

UL Type 1 Outdoor

Ballast Efficacy Factor
0.46
0.58
0.82
1.46
0.44
0.56
0.81
1.46
0.44
0.55
0.80
1.43
0.41
0.53
0.79
1.36

4, 3, 2 or 1 – F54T5HO 120 to 277 UltraStart® PRS J Can

General characteristics

10 Pack
47542

RoHS compliant

System Ballast Factor
1.00
1.01
0.96
1.12
0.96
1.00
0.96
1.12
1.00
1.01
0.96
1.12
0.96
1.00
0.96
1.12

29726 – GE454MVPSN1

2 – F54T5HO PRS UNV 50/60 Hz D Can

Supply Current Frequency

16.10 in (408.70 mm)
0.25 in (6.35 mm)
3.15 lb
Side
8 ft
18 AWG
Length (± 1 in)
25 in (636 mm)
34 in (863 mm)
34 in (863 mm)
45 in (1140 mm)
3.5 in (90 mm)

Sign
Ballasts

• Electronic ballasts for all general fluorescent applications
• Extends lamp life in frequently switched applications
• Reduced lamp replacement cost; ideal for use with occupancy sensors

47542 – B254PUNV-DGE1C

Additional Info

IP Pack

16.7 in (424.0 mm)
1.7 in (43.2 mm)
1.36 in (34.5 mm)

Specifications by lamp and wattage
Nom. Line Current
0.99 A
0.43 A
0.61 A
0.27 A
0.98 A
0.43 A
0.60 A
0.26 A
0.91 A
0.40 A
0.56 A
0.25 A

FCC – CLASS A Non-Consumer

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating

DIY Pack

Wiring diagram – LFL 4c – see example on page 82
Case dimensions – Ref Drawing -E – see page 83
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black, White and Grey
Red and Blue
Red/White and Blue/White
Yellow and Orange
Green

T12
Fluorescent Ballasts

# of Lamps
Line Volts
System Watts
2
120
117
2
277
115
1
120
72
FT50W/4P
1
277
72
2
120
116
2
277
115
1
120
71
F54T5/HO
1
277
71
2
120
109
2
277
107
1
120
66
F54T5WM
1
277
66
Other compatible lamps: FC12T5HO, F58T8, FT39W/4P, FT55W/4P

Dimensions
Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
105°F (41°C)
90°C (194°F)
Normal
Active
A (20-24 decibels)
Auto-restart, End-of-Life Protection (EOL), Thermally protected,
Anti-striation control

Additional Info

Specifications by lamp and wattage
Lamp

4 – 1 – F54T5HO 120 – 277 UltraStart® PRS High Temp E Can
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating

Wiring diagram – LFL 4a, LFL 4b – see example on page 82
Case dimensions – Ref Drawing -F – see page 83
Length (L)
11.8 in (298.45 mm)
Width (W)
1.7 in (43.18 mm)
Height (H)
1.2 in (30.48 mm)
Mounting dimensions
Mount Length (M)
11.1 in (282.95 mm)
Mount Slots (MS)
0.25 in (6.35 mm)
Weight
1.85 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
8 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Length (± 1 in)
White and Black
25 in (635 mm)
Blue and Red
34 in (864 mm)
Yellow
45 in (1143 mm)

Electrical characteristics
Supply Current Frequency

T5 High Output - UltraStart® Programmed Start

T5
Fluorescent Ballasts

Electronic – Programmed / Rapid Start
Programmed start
Parallel
10%
104°F (40°C)
90°C (194°F)
Normal
Active
A (20-24 decibels)
Auto-restart, End-of-Life Protection (EOL), Thermally protected,
Universal voltage, Anti-striation control

• Lower Maintenance Costs with Parallel Lamp Operation
• Fast starting time <700 ms
• Auto Restart withstands temporary losses in power without the need to cycle power
• UltraCool™ Operation 90C case rating
• Bi-Level Switching
• Anti-striation control for better light quality, with no striations

99649 – GE454MVPS90-E

T8
Fluorescent Ballasts

• High Efficiency T5 ballast with Continuous Cathode Cutout Technology
• Lower Maintenance Costs with Parallel Lamp Operation
• Fast Starting Time <700ms
• Multi-Voltage technology means a single ballast handles voltage from 108V to 305V
• Auto-Restart withstands temporary losses in power without the need to cycle power
• UltraCool™ Operation 90C case rating

99651 – GE254MVPS90-F

T5 High Output – Programmed Start
T5 Electronic Programmed Start For F24 (2 ft), F39 (3 ft), F54 (4 ft), F80 (5 ft) HO T5 Lamps*

Quick Reference
Guides

gelighting.com

Quick Reference
Guides

gelighting.com

Wiring Diagrams
T5 Fluorescent Ballasts

Case Dimensions
T5 Fluorescent Ballasts
LFL 4b

LFL 4c

LFL 62-1

-A Can, -E, -F
T8
Fluorescent Ballasts

LFL 4a

T5
Fluorescent Ballasts

-C Can

0.59”

T12
Fluorescent Ballasts

1.18”

R
R
Y
Y
B
B

G
N
L
13.75”
14.25”

1.00”

Sign
Ballasts

-D Can
LFL 62-2
1.18”

Compact Fluorescent
Ballasts

0.59”

R
R
Y
Y
B
B

G
N
L
16.28”
16.88”

1.00”

-J

See page 195 for warranty information.

See page 195 for warranty information.

*T5 lamp lengths are noted to nearest foot and are not exact lengths as noted in feet. See GE Lamp Catalog for exact lamp length.

83

HID Electromagnetic
Ballasts

82

HID Electronic
Ballasts

LFL 62-3

Quick Reference
Guides

gelighting.com

ProLine® T12 Multivolt 120V – 277V
T12 Electronic Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps
ProLine® T12 Multivolt 120V – 277V

T8
Fluorescent Ballasts

• High-performance electronic ballast for all general fluorescent applications
• Multi-voltage technology handles voltage from 120 to 277V
• Light weight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

24107 – GE-240-RS-MV-N
2 or 1 – F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12

General characteristics

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing ST – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White and Black
Yellow

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information

Electronic T12

Std. pack
24107

GE multivolt and dedicated voltage ProLine® T12 high-performance ballasts are designed for
replacement of magnetic T12 electronic ballasts during maintenance or retrofits. GE multivolt
ProLine® T12 ballasts have the same wiring and mounting requirements as standard magnetic
ballasts and provide up to 20% energy savings by simply replacing the ballast.

Lamp

• Parallel operation — if one lamp fails,
others remain lit
• Significantly quieter than magnetic
• High-frequency operation virtually
eliminates lamp flickering typical in T12
electromagnetic systems
• Five-year limited ballast warranty

• Complete line of ballasts for 2-to-8 foot
lamps, circleline and high-output lamps
• 100% thermally protected
• High-grade lamination steel assures lowest
wattage loss
• UL, CSA and/or cUL approved
• 888-GEBALLAST on every ballast
• Two-year limited ballast warranty

Color-Coded Ballast and Outer Box Labels
120V – Yellow
277V – Red

# of Lamps
Line Volts
System Watts
2
120
75
2
277
58
1
120
42
F40T10
1
277
42
2
120
74
2
277
73
1
120
48
F40T12
1
277
48
2
120
63
2
277
62
1
120
41
F34T12
1
277
41
2
120
60
2
277
58
1
120
37
F30T12
1
277
37
Other compatible lamps: F20T12, F30T12/WM

Safety and performance

G E M - 2

Maximum number of
lamps supported by
this ballast: 1, 2, 3, 4

84

Lamp Watts
(Primary Lamp)
T8 = 32 – 4 foot,
59 – 8 foot
T12 = 40 – 4 foot,
60 – 8 foot
T12 Electronic =
40 – 2-4 foot, 2 pin
60 – 4-8 foot, 1 pin
96 – 4-8 foot HO,
2 pin
T12 Magnetic =
40 – 2-4 foot, 2 pin
96 – 4-8 foot, 2 pin

IS = Instant Start,
default if not shown
RS = Rapid Start
PH = Preheat
PT= Preheat/Trigger
H = Hybrid
D50 = Dimming (min level)
HO = High Output
VHO = Very High Output

120V – Yellow
277V – Red
220V – Green
240V – Orange
347 – Gray

Pack Type
IP = Individual corrugated
box per ballast
84T = Pallet bulk pack
(84=840, 42=420 ballasts)
DIY = Shrinkwrap ballast in
tray pack
DIY72 = Shrinkwrap ballast
in pallet pack (Qty)
No extension = 10 pack

See page 195 for warranty information.

Ballast Efficacy

0.89
0.89

1.20
1.21

0.87
0.87

1.38
1.40

UL Type HL

UL Class P

NRCan

Power Factor % (>=)
99
93
99
88
99
94
99
89
99
93
99
86
99
93
99
86

FCC Part 18 Class B at 120 volts

cUL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD (<=)
7
16
10
16
7
14
10
17
8
15
10
19
8
16
10
22

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
50 / 10
50 / 10
0 / -18
0 / -18
0 / -18
0 / -18
50 / 10
0 / -18
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10

UL Listed RoHS compliant

• High-performance electronic ballast for all general fluorescent applications
• Light weight, low-profile housing

ProLine® T12 120V – 277V
2 – F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12

General characteristics

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Electronic – Programmed / Rapid Start
Rapid start
Series
10%
221°F (105°C)
70°C (158°F)
Normal
Passive
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
Std. pack
97498

Pallet Pack

DIY Pack
97499

IP Pack

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing B1 – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Yellow
Yellow

9.5 in (241.30 mm)
1.3 in (33.02 mm)
1.0 in (25.40 mm)
8.8 in (225.80 mm)
0.9 in (22.35 mm)
0.3 in (7.92 mm)
1.38 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
48 in (1219 mm)
36 in (914 mm)

Specifications by lamp and wattage
F40T12
FT36W/4P
F34T12
F30T12
F12T9
F8T9
F16T9

# of Lamps
2
2
2
2
2
2
2
2
1
1
1

Line Volts
120
120
120
120
120
120
120
120
120
120
120

System Watts
73
73
72
70
63
62
59
59

Safety and performance

See page 195 for warranty information.

CSA

Nom. Line Current
0.62 A
0.62 A
0.62 A
0.60 A
0.54 A
0.53 A
0.50 A
0.50 A

UL Type 1 Outdoor

System Ballast Factor
1.10
0.85
0.85
0.58
0.85
0.85
0.92
0.53

ANSI – 62.41

UL Type HL

Ballast Efficacy
1.50
1.16
1.18
0.82
1.34
1.37
1.55
0.89

Power Factor % (>=)
1
98
98
0.98
98
96
0.92
0.95

FCC Part 18 Class B at 120 volts

UL Class P

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

ANSI – C82.11

THD (<=)
20
20
20
20
20
25
25
0.53

UL Listed

Min. Starting Temp (°F/°C)
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
NRCan

85

HID Electromagnetic
Ballasts

GE Ballast
M = Electromagnetic
Ballast
GEH = HID

3 2 - H O - R S - 1 2 0 - D I Y

UL Type 1 Outdoor

System Ballast Factor

97498 – GE240RS120

Lamp
F25T12

GE Ballast LFL magnetic nomenclature

Nom. Line Current
0.63 A
0.22 A
0.35 A
0.17 A
0.67 A
0.30 A
0.41 A
0.19 A
0.56 A
0.26 A
0.35 A
0.17 A
0.31 A
0.22 A
0.31 A
0.16 A

HID Electronic
Ballasts

Packaging
• Standard 10 packs
• IP Packs – individually packed with
instructions
• DIY – shrink-wrapped and tray-packed
with instructions

Specifications by lamp and wattage

Compact Fluorescent
Ballasts

Electromagnetic T12

IP Pack

Sign
Ballasts

Performance Features
• GE240RSMVN and GE240RS120 comply
with FCC for residential use
• Low-profile and lightweight housing
simplifies installation and reduces
transportation costs (GE240 = 1.3 lbs. lighter
than magnetic; GE260 = 5.3 lbs. lighter than
magnetic)

DIY Pack
24773

8.9 in (225.80 mm)
1.7 in (42.92 mm)
0.3 in (7.92 mm)
2.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
25 in (635 mm)
48 in (1219 mm)

T12
Fluorescent Ballasts

The DOE ballast ruling effective April 1, 2005, prevents the sale of 4 foot and 8 foot lamp
electromagnetic ballasts that operate T12 lamps and do not meet federal ballast efficiency
requirements. GE ProLine® T12 electronic ballasts meet the DOE minimum ballast efficiency
requirements and also allow facility managers to reduce ballast maintenance inventories by
consolidating the number of ballasts needed. GE ProLine® T12 ballasts operate both energysaving and standard wattage lamps and are also multi-voltage (120-277V). With 2 ballasts, the
multi-voltage ProLine® T12 can consolidate over 40 different magnetic ballasts.

Pallet Pack

9.5 in (241.30 mm)
2.4 in (60.45 mm)
1.6 in (39.37 mm)

T5
Fluorescent Ballasts

Understanding T12
Electronic Ballasts

Electronic – Programmed/ Rapid Start
Rapid start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Quick Reference
Guides

gelighting.com

ProLine® T12 Multivolt 120V – 277V
T12 Electronic Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12, F40T10 Lamps

ProLine® T12 Multivolt 120V – 277V
T12 Electronic Ballasts For T12 4 ft – 8 ft Slimline Lamps

72110 – GE140RS120-DIY

24108 – GE-260-IS-MV-N

ProLine® T12 120V

ProLine® T12 Multivolt 120V – 277V

1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF DIY Pack

2 or 1 – F96T12 Instant Start 120 to 277

Dimensions

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
Std. pack

Pallet Pack

DIY Pack
72110

General characteristics

Wiring diagram – LFL 2 – see example on page 102
Case dimensions – Ref Drawing 29 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White and Black

IP Pack

6.46 in (164.08 mm)
1.37 in (34.80 mm)
1.0 in (25.40 mm)
6.0 in (152.40 mm)
1.37 in (34.80 mm)
Side

Line Volts
120
120
120
120

Safety and performance

System Watts
36
36
30
28

Electrical characteristics
Order information
Std. pack
24108

System Ballast Factor
0.88
1.33
0.88
0.93
cUL Listed

Ballast Efficacy Factor
2.44
3.69
2.93
3.32

UL Listed

Power Factor % (>=)
57
57
55
58

Crest Factor (<=)
1.58
1.54
1.50
1.51

THD (<=)
150
150
150
150

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18

Lamp

F96T12

ANSI 62.41

F84T12

F96T12/WM

F72T12

F96T12/WMP

ProLine® T12 Multivolt 120V – 277V

F64T12

3 or 2 – F40 or F34T12 Rapid Start 120 to 277 ProLine® T12

General characteristics

DIY Pack
24776

IP Pack

Order information
DIY Pack
24774

IP Pack

F48T12

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)

# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1

Line Volts
120
277
120
277
120
277
277
120
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277

System Watts
144
140
90
89
126
124
78
77
115
113
72
71
109
107
69
68
101
99
63
63
98
97
62
62
92
91
59
59
73
73
48
48

Safety and performance

Nom. Line Current
1.21 A
0.52 A
0.76 A
0.33 A
1.05 A
0.46 A
0.29 A
0.65 A
0.94 A
0.41 A
0.59 A
0.27 A
0.91 A
0.40 A
0.58 A
0.26 A
0.87 A
0.37 A
0.54 A
0.24 A
0.84 A
0.36 A
0.53 A
0.23 A
0.77 A
0.34 A
0.49 A
0.23 A
0.61 A
0.28 A
0.41 A
0.20 A

UL Type 1 Outdoor

NRCan

System Ballast Factor
0.87
0.87

Ballast Efficacy Factor
0.60
0.62

0.90
0.90

0.78
0.79

UL Type HL

FCC – CLASS A Non-Consumer

Power Factor % (>=)
99
97
99
96
99
98
96
99
99
97
99
95
99
97
99
95
99
97
99
95
99
97
99
95
99
96
99
94
99
95
99
89
UL Class P

cUL Listed

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD (<=)
6
14
9
20
8
16
27
10
7
16
10
22
9
17
11
22
9
17
11
22
9
17
11
22
9
18
12
21
10
21
13
27

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
2.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
33 in (838 mm)
25 in (635 mm)
48 in (1219 mm)

HID Electronic
Ballasts

Specifications by lamp and wattage
Lamp

Safety and performance
86

UL Type 1 Outdoor

Nom. Line Current
0.98 A
0.43 A
0.74 A
0.33 A
90.00 A
0.39 A
0.67 A
0.30 A
0.81 A
0.36 A
0.60 A
0.27 A
0.75 A
0.33 A
0.25 A
0.55 A

UL Type HL

System Ballast Factor
0.89
0.89

Ballast Efficacy Factor
0.78
0.80

0.87
0.87

0.90
0.92

FCC – CLASS A Non-Consumer

UL Class P

cUL Listed

Power Factor % (>=)
99
97
99
96
99
97
99
96
99
96
99
95
99
97
95
99

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD (<=)
5
11
6
12
5
12
6
13
6
12
7
13
5
12
13
6

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

87

HID Electromagnetic
Ballasts

# of Lamps
Line Volts
System Watts
3
120
114
3
277
111
2
120
86
F40T12
2
277
85
3
120
107
3
277
105
2
120
80
F40T10
2
277
79
3
120
96
3
277
94
2
120
71
F34T12
2
277
70
3
120
90
3
277
87
2
277
67
F30T12
2
120
66
Other compatible lamps: F30T12/WM, F40T12/WMP

Compact Fluorescent
Ballasts

Wiring diagram – LFL PS3 – see example on page 101
Case dimensions – Ref Drawing ST – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
Red/White
White and Black
Yellow

50 Hz/60 Hz

Pallet Pack

F60T12

Dimensions
Electronic – Programmed / Rapid Start
Rapid start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics

Std. pack
24109

Pallet Pack

8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
2.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
67 in (1702 mm)
59 in (1499 mm)
25 in (635 mm)
25 in (635 mm)

Sign
Ballasts

• High-performance electronic ballasts for all general fluorescent applications
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

24109 – GE-340-RS-MV-N

Supply Current Frequency

50 Hz/60 Hz

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)

Specifications by lamp and wattage
Nom. Line Current
0.53 A
0.53 A
0.45 A
0.41 A

Meets FCC Part 18 (Class B) Consumer Limits

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagram – LFL 14 – see example on page 101
Case dimensions – Ref Drawing ST – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
Red
White
Black

T12
Fluorescent Ballasts

# of Lamps
1
1
1
1

Electronic – Multivolt Instant Start
Instant start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Supply Current Frequency

Length (± 1 in)
25 in (635 mm)
15 in (381 mm)

Specifications by lamp and wattage
Lamp
F40T12/40W
F40T12/25W
F34T12/34W
F30T12/30W

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Electronic – Programmed/ Rapid Start
Rapid start
Parallel
10%
105°F (41°C)
75°C (167°F)
Normal
Active
A (20-24 decibels)
End-of-Life Protection (EOL), Thermally protected

T8
Fluorescent Ballasts

General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• High-performance electronic ballasts for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage

Quick Reference
Guides

gelighting.com

T12 Electronic Ballasts T12 High Output

T12 Electronic Ballasts T12 High Output

For T12 High Output Lamps

For T12 High Output Lamps
• Electronic ballasts for all general fluorescent applications

80162 – B295SR120HP

72109 – GE296HO-MV-N
T12 High Output ProLine® T12 Multivolt 120V – 277V

2 – F96T12HOES RS 120

2 or 1 – F96T12 HO RS 120 to 277 Multivolt ProLine®

General characteristics

Dimensions
Electronic – Programmed / Rapid Start
Rapid start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
Std. pack
80162

Pallet Pack

DIY Pack

General characteristics

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing SL – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Yellow

IP Pack

11.75 in (298.45 mm)
3.1 in (79.50 mm)
1.7 in (45.21 mm)
11.4 in (289.81 mm)
2.0 in (50.80 mm)
0.3 in (7.92 mm)
4.00 lbs
Side
12 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
46 in (1168 mm)
66 in (1676 mm)

System Watts
208
185
174
169

Safety and performance

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing SL – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge

Supply Current Frequency

50 Hz/60 Hz

11.8 in (299.72 mm)
2.15 in (54.61 mm)
1.61 in (40.89 mm)
11.0 in (279.40 mm)
2.15 in (54.61 mm)
Side

Order information
Std. pack
72109

Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage
Nom. Line Current
1.77 A
1.60 A
1.47 A
1.40 A

UL Type 1 Outdoor

System Ballast Factor
0.90
0.89
0.88
0.95

Canadian Energy Standards

Ballast Efficacy Factor
0.43
0.48
0.50
0.56

UL Type HL

Power Factor % (>=)
99
99
99
99

FCC – CLASS A Non-Consumer

Crest Factor (<=)
1.7
1.7
1.7
1.7

UL Class P

CSA

THD (<=)
10
10
10
10

Min. Starting Temp (°F/°C)
-20 / -29
-20 / -29
60 / 16
-20 / -29

UL Listed

Lamp

F96T12/HO
F96T12/HO/
ES/95W
F72T12/
HO/85W
F60T12/
HO/75W
F48T12/
HO/60W

# of Lamps
2
2
1
1
2
2
2
2
2
2
2
2

Line Volts
120
277
120
277
120
277
120
277
120
277
120
277

System Watts
196
196
104
104
164
164
154
154
132
132
112
113

Safety and performance

cUL Listed

Nom. Line Current
1.65 A
0.73 A
0.88 A
0.42 A
1.38 A
0.62 A
1.30 A
0.57 A
1.10 A
0.50 A
0.95 A
0.43 A
UL Listed

System Ballast Factor
0.90
0.90
0.92
0.92
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90

Ballast Efficacy Factor
0.46
0.46
0.88
0.88
0.55
0.55
0.58
0.58
0.68
0.68
0.80
0.80

Power Factor % (>=)
99
97
99
95
99
96
99
96
99
96
99
95

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

THD (<=)
10
10
15
15
10
10
10
10
10
10
15
15

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

FCC Part 18 (Class A) Non Consumer

Sign
Ballasts

• Electronic ballasts for all general fluorescent applications

80163 – B295SR277HP

T12
Fluorescent Ballasts

Line Volts
120
120
120
120

Electronic – Programmed/ Rapid Start
Rapid start
Series
10%
105°F (41°C)
75°C (167°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics

Specifications by lamp and wattage
Lamp
# of Lamps
F96T12/HO
2
F84T12/HO
2
F96T8/HO/WM
2
F72T12/HO
2

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T8
Fluorescent Ballasts

T12 High Output 120V Electronic

T12 High Output 277V Electronic
2 – F96T12 HOES RS 277

General characteristics

Dimensions
Electronic – Programmed / Rapid Start
Rapid start
Series
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing SL – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Yellow

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Order information
Std. pack
80163

Pallet Pack

DIY Pack

IP Pack

11.75 in (298.45 mm)
3.1 in (79.50 mm)
1.7 in (45.21 mm)

Compact Fluorescent
Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

11.4 in (289.81 mm)
2.0 in (50.80 mm)
0.3 in (7.92 mm)
4.00 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
46 in (1168 mm)
66 in (1676 mm)

HID Electronic
Ballasts

Specifications by lamp and wattage
Lamp
# of Lamps
F96T12/HO
2
F84T12/HO
2
F96T8/HO/WM
2
F72T12/HO
2

Line Volts
277
277
277
277

Safety and performance

Nom. Line Current
0.76 A
0.69 A
0.63 A
0.61 A

UL Type 1 Outdoor

System Ballast Factor
0.90
0.91
0.88
0.95

Canadian Energy Standards

Ballast Efficacy Factor
0.43
0.49
0.51
0.56

UL Type HL

Power Factor % (>=)
99
99
99
99

FCC – CLASS A Non-Consumer

UL Class P

Crest Factor (<=)
1.7
1.7
1.7
1.7
CSA

THD (<=)
10
10
10
10

Min. Starting Temp (°F/°C)
-20 / -29
-20 / -29
60 / 16
-20 / -29

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

89

HID Electromagnetic
Ballasts

88

System Watts
208
185
174
169

Quick Reference
Guides

gelighting.com

T12 Magnetic Ballasts

T12 Magnetic Ballasts

For 2 ft Circleline, Preheat T12 Lamps

For 2 ft, Circleline, Preheat T12 Lamps
• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

89711 – GEM120PH120DIY
1 – F20T12, F15T8, F1512, F14T8, F18T8, 120V, Magnetic Ballast (200H2)

2 – FC12T9, FC16T9, FC8T9, FC12T9, 120V, Magnetic (726VLHWSTCP)

General characteristics

Dimensions
Magnetic – Rapid Start
Preheat
Series
5%
105°F (41°C)
90°C (194°F)
Normal
A (20-24 decibels)

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Std. pack

Pallet Pack

DIY Pack
89711

General characteristics

Wiring diagram – LFL 21 – see example on page 101
Case dimensions – Ref Drawing 2 – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black

IP Pack

3.0 in (77.01 mm)
1.25 in (31.75 mm)
1.75 in (44.45 mm)
3.0 in (77.01 mm)
2.75 in (69.85 mm)
0.2 in (5.58 mm)
0.65 lbs
Side
10 ft
18 AWG
Length (± 1 in)
9 in (229 mm)

Line Volts
120
120
120
120
120

System Watts
18
18
18
18
18

Safety and performance

UL Type HL

System Ballast Factor
0.84
0.95
0.82
0.65
0.69
cUL Listed

Ballast Efficacy Factor
4.66
5.27
4.55
3.61
3.83

CSA

Electrical characteristics
Order information
Std. pack

Power Factor % (>=)
48
48
52
57
59

Crest Factor (<=)
1.6
1.6
1.6
1.6
1.6

THD (<=)
10
10
10
10
10

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10

1 – F20T12, F15T8, F15T12, F14T12, 120V, Magnetic Ballast (546BTCP)

Dimensions

A (20-24 decibels)
Auto-restart, Thermally protected

60 Hz

DIY Pack
89712

IP Pack

System Watts
30

Safety and performance

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.80
0.96
0.86
1.01
UL Class P

UL Type HL

System Ballast Factor
0.56
0.45
UL Class P

Ballast Efficacy Factor
1.86

cUL Listed

Power Factor % (>=)
0.45
0.54

Crest Factor (<=)
1.5
1.5

THD (<=)
10
10

Min. Starting Temp (°F/°C)
50 / 10
50 / 10

UL Listed

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

86227 – GEM1FC8T9RS120IP
T12 Magnetic Ballasts

Ballast Efficacy Factor
2.75
3.42
3.18
3.88

Power Factor % (>=)
40
39
36
37

6.4 in (163.57 mm)
1.9 in (48.51 mm)
1.9 in (49.27 mm)
6.4 in (163.57 mm)
6.0 in (152.40 mm)
0.25 in (6.35 mm)
2.10 lbs
Side
10 ft
18 AWG
Length (± 1 in)
10 in (254 mm)
17 in (432 mm)
18 in (457 mm)
14 in (356 mm)

Crest Factor (<=)
1.5
1.6
1.6
1.5

THD (<=)
10
10
10
10

Dimensions
Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

cUL Listed

Wiring diagram – LFL 29 – see example on page 102
Case dimensions – Ref Drawing 9 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Black and White
White
Blue
Red

A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Std. pack

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
50 / 10
50 / 10

Pallet Pack

DIY Pack
89722

IP Pack
86227

6.4 in (163.57 mm)
1.9 in (48.51 mm)
1.9 in (49.27 mm)
6.4 in (163.57 mm)
6.0 in (152.40 mm)
0.25 in (6.35 mm)
2.10 lbs
Side
10 ft
18 AWG
Length (± 1 in)
10 in (254 mm)
12 in (305 mm)
10 in (254 mm)
9 in (229 mm)
9 in (229 mm)

Specifications by lamp and wattage
Lamp
FC8T9
FC6T9

# of Lamps
1
1

Line Volts
120
120

System Watts
25
24

Safety and performance
UL Type 1 Outdoor

Nom. Line Current
0.55 A
0.46 A

Nom. Line Current
0.58 A
0.63 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.80
0.81
UL Class P

Ballast Efficacy Factor
3.20
3.37

cUL Listed

Power Factor % (>=)
50
50

Crest Factor (<=)
1.6
1.6

THD (<=)
10
10

Min. Starting Temp (°F/°C)
50 / 10
50 / 10

UL Listed

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

91

HID Electromagnetic
Ballasts

90

Nom. Line Current
0.59 A
0.59 A
0.62 A
0.59 A

Line Volts
120
120

HID Electronic
Ballasts

Safety and performance

System Watts
29
28
27
26

# of Lamps
1
1

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Line Volts
120
120
120
120

Lamp
F16T9
F12T9

General characteristics

Wiring diagram – LFL 21 – see example on page 101
Case dimensions – Ref Drawing 9 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
White
Blue
Red

Order information

# of Lamps
1
1
1
1

IP Pack

Compact Fluorescent
Ballasts

Magnetic – Rapid Start
Trigger start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Electrical characteristics

Lamp
F20T12
F15T8
F14T12
F15T12

DIY Pack
89720

1 – FC8T9, FC6T9, RS, 120V, Magnetic Ballast (547RSWSTCP)

General characteristics

Pallet Pack

Pallet Pack

0.30 in (7.87 mm)
2.70 lbs
Side
10 ft
18 AWG
Length (± 1 in)
12 in (305 mm)
12 in (305 mm)

Sign
Ballasts

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

T12 Magnetic Ballasts

Std. pack

60 Hz

6.5 in (166.62 mm)
6.0 in (152.40 mm)

UL Listed

89712 – GEM120TC120DIY

Supply Current Frequency

A (20-24 decibels)
Auto-restart, Thermally protected

6.5 in (166.62 mm)
2.3 in (60.45 mm)
1.6 in (42.92 mm)

Specifications by lamp and wattage
Nom. Line Current
0.31 A
0.31 A
0.28 A
0.25 A
0.26 A

UL Type 1 Outdoor

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagram – LFL 037 – see example on page 102
Case dimensions – Ref Drawing 10 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White
Black

T12
Fluorescent Ballasts

# of Lamps
1
1
1
1
1

Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Supply Current Frequency

Specifications by lamp and wattage
Lamp
F14T8
F15T12
F15T8
F18T8
F20T12

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T12 Magnetic Ballasts

T8
Fluorescent Ballasts

T12 Magnetic Ballasts

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

89720 – GEM1FC16T9RS120

Quick Reference
Guides

gelighting.com

T12 Magnetic Ballasts

T12 Magnetic Ballasts

For 2 ft, Circleline, Preheat T12 Lamps

For F30, F34/40 (4 ft) T12 Lamps
• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

89717 – GEM1FC12T9RS120
2 – FC12T9, RS, 120V, Magnetic Ballast (449LRWSTCP)

1 – F40T12, F40T12, 120V, Magnetic Ballast (412LSLHTCP)

General characteristics

Dimensions
Magnetic – Rapid Start
Rapid start
Series
5%
104°F (40°C)
90°C (194°F)
Normal
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Std. pack
89717

Pallet Pack

DIY Pack

General characteristics

Wiring diagram – LFL 037 – see example on page 102
Case dimensions – Ref Drawing D10 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White
White and Black
White
Blue
Red

IP Pack

11.7 in (297.18 mm)
3.1 in (78.74 mm)
1.8 in (45.72 mm)
11.7 in (297.18 mm)
11.3 in (287.02 mm)
0.30 in (7.62 mm)
2.70 lbs
Side
10 ft
18 AWG
Length (± 1 in)
10 in (254 mm)
12 in (305 mm)
10 in (254 mm)
9 in (229 mm)
9 in (229 mm)

System Watts
49

Safety and performance

Nom. Line Current
0.70 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.65
UL Class P

Ballast Efficacy Factor
1.33

Power Factor % (>=)
59

Crest Factor (<=)
1.7

THD (<=)
10

Order information

Min. Starting Temp (°F/°C)
50 / 10

Safety and performance

UL Type 1 Outdoor

System Ballast Factor
1.00
1.00
0.97

UL Type HL

UL Class P

Ballast Efficacy Factor
2.00
2.00
2.25

CSA

Power Factor % (>=)
97
97
93
97

Crest Factor (<=)
1.6
1.6
1.6
1.6

THD (<=)
15
15
15
15

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
60 / 16
50 / 10

UL Listed

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

89709 – GEM140RS120DIY
T12 Magnetic Ballasts

IP Pack

6.5 in (166.62 mm)
2.3 in (60.45 mm)
1.6 in (42.92 mm)
6.5 in (166.62 mm)
6.0 in (152.40 mm)
0.30 in (7.87 mm)
2.50 lbs
Side
10 ft
18 AWG
Qty
Exit
1
Left
1
Left
2
Right
2
Right

Dimensions
Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Wiring diagram – LFL 8 – see example on page 102
Case dimensions – Ref Drawing 9 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue

A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency
Length (± 1 in)
10 in (254 mm)
15 in (381 mm)
15 in (381 mm)
18 in (457 mm)

60 Hz

Order information
Std. pack

Pallet Pack

DIY Pack
89709

IP Pack

6.4 in (163.57 mm)
1.9 in (48.51 mm)
1.9 in (49.27 mm)
6.4 in (163.57 mm)
6.0 in (152.40 mm)
0.25 in (6.35 mm)
2.10 lbs
Side
10 ft
18 AWG
Length (± 1 in)
10 in (254 mm)
30 in (762 mm)
36 in (914 mm)
36 in (914 mm)

Specifications by lamp and wattage
Nom. Line Current
0.59 A
0.63 A
0.60 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.68
0.50
0.64
UL Class P

Ballast Efficacy Factor
1.83
1.38
1.77

cUL Listed

Power Factor % (>=)
52
48
50

Crest Factor (<=)
1.5
1.4
1.5

THD (<=)
15
15
15

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
50 / 10

UL Listed

Lamp
F40T12
F30T12
F48T12/25W
F34T12

# of Lamps
1
1
1
1

Line Volts
120
120
120
120

System Watts
36
35
32
31

Safety and performance

See page 195 for warranty information.

See page 195 for warranty information.

Nom. Line Current
0.63 A
0.70 A
0.59 A
0.65 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.60
0.67
0.96
0.58
UL Class P

Ballast Efficacy Factor
1.66
1.91
3.00
1.87

cUL Listed

Power Factor % (>=)
47
42
45
40

Crest Factor (<=)
1.5
1.5
1.5
1.5

THD (<=)
15
15
15
15

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
50 / 10
50 / 10

UL Listed

93

HID Electromagnetic
Ballasts

92

System Watts
37
36
36

Nom. Line Current
0.43 A
0.43 A
0.39 A

HID Electronic
Ballasts

Line Volts
120
120
120

System Watts
50
50
43

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
# of Lamps
2
2
2

Line Volts
120
120
120
120

Compact Fluorescent
Ballasts

60 Hz

Order information

Lamp
F20T12
F15T12
F15T8

# of Lamps
1
1
1
1

General characteristics

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing 10 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
White
Blue and Red
Yellow

A (20-24 decibels)
Auto-restart, Thermally protected

DIY Pack
80819

IP Pack

Sign
Ballasts

Magnetic – Rapid Start
Trigger start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Pallet Pack

Lamp
F40T10
F40T12
F34T12
F40T12/WMP

Safety and performance

Dimensions

Electrical characteristics

Std. pack

DIY Pack
89714

8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
3.40 lbs
Side
10 ft
18 AWG
Length (± 1 in)
22 in (559 mm)
26 in (660 mm)
34 in (864 mm)

1 – F40T12, F30T12, F48/25W, 120V, Magnetic Ballast (413CTCP)

General characteristics

Supply Current Frequency

Pallet Pack

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)

Specifications by lamp and wattage

2 – F20T12, F15T8, F15T12, F14T12, 120V, Magnetic Ballast (447LRVLHTCP)
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

60 Hz

Std. pack

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

T12 Magnetic Ballasts

A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics

CSA

80819 – GEM220TS120DIY

Wiring diagram – LFL 2 – see example on page 102
Case dimensions – Ref Drawing ST – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue
Red

T12
Fluorescent Ballasts

Line Volts
120

Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Supply Current Frequency

Specifications by lamp and wattage
Lamp
# of Lamps
FC8T9/FC12T9
2

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T12 Magnetic Ballasts

T8
Fluorescent Ballasts

T12 Magnetic Ballasts

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)
• Energy saving modified rapid start

89714 – GEM140HRS120DIY

Quick Reference
Guides

gelighting.com

T12 Magnetic Ballasts

T12 Magnetic Ballasts

For F30, F34/40 (4 ft) T12 Lamps

For F30, F34/40 (4 ft) T12 Lamps
• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

80644 – GEM230RS120DIY
2 – F30T12, 120V, Magnetic Ballast (573LTCP)

2 – F40T12, RS, 120V, Magnetic Ballast (446LSLHTCP)

General characteristics

Dimensions
Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Std. pack

Pallet Pack

DIY Pack
80644

General characteristics

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing ST – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White and Black
Yellow

IP Pack

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)
8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
3.60 lbs
Side
10 ft
18 AWG
Length (± 1 in)
22 in (559 mm)
20 in (508 mm)
30 in (762 mm)

# of Lamps
2
2

Line Volts
120
120

System Watts
64
54

UL Type HL

System Ballast Factor
0.80
0.75
UL Class P

Electrical characteristics
Order information

Ballast Efficacy Factor
1.25
1.38
CSA

Power Factor % (>=)
95
95

Crest Factor (<=)
1.7
1.7

THD (<=)
20
20

Min. Starting Temp (°F/°C)
50 / 10
60 / 16

UL Listed

Lamp
F40T10
F40T12
F40T12/WM

# of Lamps
2
2
2

Line Volts
120
120
120

DIY Pack
46958

System Watts
87
87
73

Safety and performance

2 – F40T12, F40T12, 120V, Magnetic Ballast (420LTCP)

IP Pack
86139

Nom. Line Current
0.73 A
0.73 A
0.64 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.95
0.95
0.89
Circle E

Ballast Efficacy Factor
1.09
1.09
1.21

UL Class P

Dimensions

A (20-24 decibels)
Auto-restart, Thermally protected

60 Hz

Order information
DIY Pack
89710

Safety and performance

System Watts
72
72

IP Pack

Nom. Line Current
0.62 A
0.62 A

UL Type 1 Outdoor

T12 Magnetic Ballasts
General characteristics

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing ST – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Yellow

UL Listed

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)
8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
3.40 lbs
Side
10 ft
18 AWG
Length (± 1 in)
12 in (305 mm)
12 in (305 mm)
12 in (305 mm)

Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing ST – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
White and Black
Yellow
Yellow

A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Std. pack

Pallet Pack

UL Type HL

System Ballast Factor
0.84
0.84

UL Class P

Ballast Efficacy Factor
1.16
1.16

Power Factor % (>=)
95
95
95

Crest Factor (<=)
1.6
1.6
1.6

THD (<=)
20
20
20

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
50 / 10

DIY Pack
89713

IP Pack
86124

UL Listed

8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
3.40 lbs
Side
10 ft
18 AWG
Length (± 1 in)
12 in (305 mm)
12 in (305 mm)
12 in (305 mm)
12 in (305 mm)
2 in (51 mm)

# of Lamps
2
2
2

Line Volts
277
277
277

System Watts
88
88
74

See page 195 for warranty information.

Nom. Line Current
0.32 A
0.32 A
0.27 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.95
0.95
0.88
Circle E

Ballast Efficacy Factor
1.07
1.07
1.18

UL Class P

CSA

Power Factor % (>=)
98
98
97

Crest Factor (<=)
1.6
1.6
1.7

THD (<=)
20
20
20

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
60 / 16

UL Listed

95

HID Electromagnetic
Ballasts

See page 195 for warranty information.

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)

Specifications by lamp and wattage
Lamp
F40T10
F40T12
F40T12/WM

Safety and performance

94

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
60 / 16

HID Electronic
Ballasts

Line Volts
120
120
120

THD (<=)
20
20
20

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

86124 – GEM240RS277IP

Specifications by lamp and wattage
# of Lamps
2
2
2

Crest Factor (<=)
1.6
1.6
1.7

Compact Fluorescent
Ballasts

Magnetic – Rapid Start
Modified rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Electrical characteristics

Lamp
F40T10
F40T12
F40T12/WMP

CSA

Power Factor % (>=)
98
98
95

2 – F40T12, RS, 277V, Magnetic Ballast (443LSLHTCP)

General characteristics

Pallet Pack

Pallet Pack

8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
3.40 lbs
Side
10 ft
18 AWG
Length (± 1 in)
12 in (305 mm)
12 in (305 mm)
12 in (305 mm)

Sign
Ballasts

T12 Magnetic Ballasts

Std. pack

60 Hz

Std. pack

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)
• Energy saving modified rapid start

89710 – GEM240HRS120DIY

Supply Current Frequency

A (20-24 decibels)
Auto-restart, Thermally protected

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)

Specifications by lamp and wattage
Nom. Line Current
0.55 A
0.45 A

UL Type 1 Outdoor

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing ST – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Yellow

T12
Fluorescent Ballasts

Safety and performance

Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Supply Current Frequency

Specifications by lamp and wattage
Lamp
F30T12
F30T12/WM

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T12 Magnetic Ballasts

T8
Fluorescent Ballasts

T12 Magnetic Ballasts

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

86139 – GEM240RS120IP

Quick Reference
Guides

gelighting.com

T12 Magnetic Ballasts

T12 Magnetic Ballasts

For F30, F34/40 (4 ft) T12 Lamps

For T12 4 ft – 8 ft Slimline Lamps
• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

86341 – GEM240RS220IP
2 – F40T12, F40T10 220V Magnetic Ballast (754LTCP)

1 – F96T12, IS, 120, Magnetic Ballast (822BRTCP)

General characteristics

Dimensions
Magnetic - Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
High
A (20-24 decibels)
Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Std. pack

Pallet Pack

DIY Pack

General characteristics

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing 10 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue and Red
Black and White
Yellow
Yellow

IP Pack
86341

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)
8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
2.04 lbs
Side
10 ft
18 AWG
Length (± 1 in)
12 in (305 mm)
12 in (305 mm)
12 in (305 mm)
12 in (305 mm)
2 in (51 mm)

Line Volts
220

Safety and performance

System Watts
40

Wiring diagram – LFL 014 – see example on page 103
Case dimensions – Ref Drawing D10 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black/White
Red
White
White and Black
Blue

B (25-30 decibels)
Auto-restart, Thermally protected

Electrical characteristics
60 Hz

Order information
Std. pack

Pallet Pack

DIY Pack
89719

IP Pack
86372

9.4 in (240.10 mm)
3.0 in (78.58 mm)
1.7 in (45.24 mm)
8.8 in (225.82 mm)
1.69 in (42.86 mm)
0.3 in (7.92 mm)
6.50 lbs
Side
10 ft
18 AWG
Length (± 1 in)
8 in (203 mm)
44 in (1118 mm)
68 in (1727 mm)
72 in (1829 mm)
48 in (1219 mm)

Specifications by lamp and wattage
Nom. Line Current

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.70

Ballast Efficacy Factor
2

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=)
90
cUL Listed

Crest Factor (<=)
1.7

UL Type CC

THD (<=)
32

Min. Starting Temp (°F/°C)
50 / 10

UL Listed

Lamp
F96T12
F72T12
F96T12/WM

# of Lamps
1
1
1

Line Volts
120
120
120

System Watts
93
78
78

Safety and performance

Nom. Line Current
0.83 A
0.73 A
0.73 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.75
0.80
0.71
UL Class P

Ballast Efficacy Factor
0.80
1.02
0.91

cUL Listed

Power Factor % (>=)
93
90
90

Crest Factor (<=)
1.85
1.85
2.00

THD (<=)
30
30
30

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
60 / 16

UL Listed

Sign
Ballasts

• Magnetic ballast construction for all general fluorescent lighting
• Instant start ballast for long lamp starting cycles and low initial cost
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

86381 – GEM196IS277IP
T12 Magnetic Ballasts

T12
Fluorescent Ballasts

# of Lamps
2

Magnetic – Standard Instant Start
Instant start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Supply Current Frequency

Specifications by lamp and wattage
Lamp
F40T12

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T12 Magnetic Ballasts

T8
Fluorescent Ballasts

T12 Magnetic Ballasts

• Magnetic ballast construction for all general fluorescent lighting
• Instant start ballast for long lamp starting cycles and low initial cost
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

86372 – GEM196IS120IP

1 – F96T12, IS, 277, Magnetic Ballast (828BRTCP)

General characteristics

Dimensions
Magnetic – Standard Instant Start
Instant start
Series
5%
105°F (41°C)
90°C (194°F)
Normal
B (25-30 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Std. pack

Pallet Pack

DIY Pack

IP Pack
86381

9.4 in (240.10 mm)
3.0 in (78.58 mm)
1.7 in (45.24 mm)
8.8 in (225.82 mm)
1.69 in (42.86 mm)
0.3 in (7.92 mm)
6.50 lbs
Side
10 ft
18 AWG
Qty
Exit
1
1
Left
1
Left
1
Right
1
Right

Length (± 1 in)
8 in (203 mm)
72 in (1829 mm)
68 in (1727 mm)
48 in (1219 mm)
44 in (1118 mm)

Specifications by lamp and wattage
Lamp
F96T12
F72T12
F96T12/WM

# of Lamps
1
1
1

Line Volts
277
277
277

System Watts
93
78
78

Safety and performance

See page 195 for warranty information.

See page 195 for warranty information.

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.75
0.80
0.71
UL Class P

Ballast Efficacy Factor
0.80
1.02
0.91

cUL Listed

Power Factor % (>=)
90
90
90

Crest Factor (<=)
1.8
1.8
2.0

THD (<=)
30
30
30

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
60 / 16

UL Listed

97

HID Electromagnetic
Ballasts

96

Nom. Line Current
0.36 A
0.30 A
0.30 A

HID Electronic
Ballasts

Wiring diagram – LFL 014 – see example on page 103
Case dimensions – Ref Drawing D10 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black/White
White and Black
White
Blue
Red

Compact Fluorescent
Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Quick Reference
Guides

gelighting.com

T12 Magnetic Ballasts

T12 Magnetic Ballasts

For T12 4 ft – 8 ft Slimline Lamps

For T12 High Output Lamps
• Magnetic ballast construction for all general fluorescent lighting
• Instant start ballast for long lamp starting cycles and low initial cost
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

86360 – GEM296IS120IP
2 – F96T12, IS, 120V, Magnetic Ballast, (806SLHTCP)

2 – F96T12HO, F96T8HO, F72T12HO, RS, 120V, Magnetic Ballast (480SLHTCP)

General characteristics
Magnetic – Standard Instant Start
Instant start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Pallet Pack

DIY Pack
46965

IP Pack
86360

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

11.6 in (296.92 mm)
3.0 in (78.48 mm)
1.8 in (45.97 mm)
11.6 in (296.92 mm)
11.25 in (285.75 mm)
0.3 in (7.87 mm)
7.70 lbs
Side
10 ft
18 AWG
Length (± 1 in)
12 in (305 mm)
12 in (305 mm)
12 in (305 mm)

Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing 29 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
White and Black
Yellow
Blue and Red
Yellow

C (31-36 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Std. pack

Pallet Pack

DIY Pack
89718

IP Pack
86164

Specifications by lamp and wattage
# of Lamps
2
2
2
2

Line Volts
120
120
120
120

System Watts
158
124
120
98

Safety and performance

Nom. Line Current
1.33 A
1.11 A
1.02 A
1.04 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.95
0.94
0.87
0.95
UL Class P

Ballast Efficacy Factor
0.60
0.75
0.72
0.96
Circle E

CSA

Power Factor % (>=)
96
93
95
87

Crest Factor (<=)
1.9
1.8
1.9
1.9

THD (<=)
30
30
30
30

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
60 / 16
50 / 10

UL Listed

Specifications by lamp and wattage
Lamp
# of Lamps
F96T12/HO
2
F96T8/HO/WM
2
F72T12/HO
2

Line Volts
120
120
120

System Watts
256
221
208

Safety and performance

T12 Magnetic Ballasts
2 – F96T12, IS, 277V, Magnetic Ballast (827SLHTCP)

Dimensions

B (25-30 decibels)
Auto-restart, Thermally protected

60 Hz

Order information
Pallet Pack

UL Class P

Circle E

T12 Magnetic Ballasts

Line Volts
277
277
277
277

DIY Pack
89715

Safety and performance

System Watts
158
125
120
98

IP Pack
86379

Nom. Line Current
0.60 A
0.47 A
0.45 A
0.41 A

UL Type 1 Outdoor

11.6 in (296.92 mm)
3.0 in (78.48 mm)
1.8 in (45.97 mm)
11.6 in (296.92 mm)
11.25 in (285.75 mm)
0.3 in (7.87 mm)
7.70 lbs
Side
10 ft
18 AWG
Qty
Exit
1
Left
2
Left
1
Right

Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Min. Starting Temp (°F/°C)
-20 / -29
60 / 16
-20 / -29

UL Listed

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing 29 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
White and Black
Yellow
Blue and Red
Yellow

C (31-36 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency
Length (± 1 in)
12 in (305 mm)
12 in (305 mm)
12 in (305 mm)

60 Hz

Order information
Std. pack

Pallet Pack

UL Type HL

System Ballast Factor
0.93
0.95
0.93
0.95
UL Class P

Ballast Efficacy Factor
0.58
0.76
0.77
0.96
Circle E

CSA

Power Factor % (>=)
96
94
95
86

Crest Factor (<=)
1.7
1.8
1.9
1.8

THD (<=)
30
30
30
30

Min. Starting Temp (°F/°C)
50 / 10
50 / 10
60 / 16
50 / 10

DIY Pack

IP Pack
86171

UL Listed

11.1 in (283.97 mm)
0.3 in (7.92 mm)
10.90 lbs
Side
10 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
46 in (1168 mm)
18 in (457 mm)
65 in (1651 mm)
48 in (1219 mm)
72 in (1829 mm)

Line Volts
277
277
277

System Watts
248
214
202

See page 195 for warranty information.

Nom. Line Current
0.92 A
0.80 A
0.78 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.97
0.95
0.97
UL Class P

Ballast Efficacy Factor
0.39
0.44
0.48
Circle E

cUL Listed

Power Factor % (>=)
98
94
95

Crest Factor (<=)
1.7
1.8
1.8

THD (<=)
20
20
20

Min. Starting Temp (°F/°C)
-20 / -29
60 / 16
-20 / -29

UL Listed

99

HID Electromagnetic
Ballasts

See page 195 for warranty information.

11.75 in (298.45 mm)
3.1 in (80.16 mm)
1.5 in (39.70 mm)

Specifications by lamp and wattage
Lamp
# of Lamps
F96T12/HO
2
F96T8/HO/WM
2
F72T12/HO
2

Safety and performance

98

THD (<=)
20
20
20

HID Electronic
Ballasts

# of Lamps
2
2
2
2

Crest Factor (<=)
1.7
1.8
1.8

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp
F96T12
F72T12
F96T12/WM
F48T12

cUL Listed

Power Factor % (>=)
98
95
97

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

86171 – GEM296HORS277IP
General characteristics

Wiring diagram – LFL 025 – see example on page 103
Case dimensions – Ref Drawing 15 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Yellow
Blue and Red

Electrical characteristics

Std. pack

UL Type HL

Ballast Efficacy Factor
0.38
0.42
0.45

Compact Fluorescent
Ballasts

Magnetic – Standard Instant Start
Instant start
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Supply Current Frequency

UL Type 1 Outdoor

System Ballast Factor
0.99
0.94
0.95

2 – F96T12HO, F96T8HO, RS, 277V, Magnetic Ballast (487SLHTCP)

General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Nom. Line Current
2.14 A
1.94 A
1.81 A

Sign
Ballasts

• Magnetic ballast construction for all general fluorescent lighting
• Instant start ballast for long lamp starting cycles and low initial cost
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

86379 – GEM296IS277IP

11.1 in (283.97 mm)
0.3 in (7.92 mm)
10.90 lbs
Side
10 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
46 in (1168 mm)
18 in (457 mm)
65 in (1651 mm)
48 in (1219 mm)
72 in (1829 mm)

T12
Fluorescent Ballasts

Lamp
F96T12
F72T12
F96T12/WM
F48T12

11.75 in (298.45 mm)
3.1 in (80.16 mm)
1.5 in (39.70 mm)

T5
Fluorescent Ballasts

Wiring diagram – LFL 39 – see example on page 103
Case dimensions – Ref Drawing 15 – see page 105
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
White
Blue and Red

B (25-30 decibels)
Auto-restart, Thermally protected

Std. pack

General characteristics

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T12 Magnetic Ballasts

T8
Fluorescent Ballasts

T12 Magnetic Ballasts

• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color-coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)

86164 – GEM296HORS120IP

T12 Magnetic Ballasts

Wiring Diagrams
T12 Fluorescent Ballasts

For T12 High Output Lamps
• Electronic ballasts for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost

80664 – 493B2

LFL PS2

LFL PS3

LFL 14

LFL 21

T8
Fluorescent Ballasts

T12 Magnetic Ballasts
2 – F73T12/BL/HO, Suntan, 120, Magnetic Ballast

General characteristics

Dimensions
Electronic – Standard Instant Start
Rapid start
Series
10%
105°F (41°C)
90°C (194°F)
Normal
Passive
A (20-24 decibels)
Thermally protected

Wiring diagram – LFL PS2 – see example on page 101
Case dimensions – Ref Drawing ST – see page 104
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White and Black
Yellow

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
80664

Pallet Pack

DIY Pack

IP Pack

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)
8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
2.50 lbs
Side
12 ft
18 AWG
Length (± 1 in)
36 in (914 mm)
30 in (762 mm)
45 in (1143 mm)

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp
F72T12/HO
F73T12/HO

# of Lamps
2
2

Line Volts
120
120

Nom. Line Current
1.6 A
1.6 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
1.00
1.00

Ballast Efficacy Factor
0.55
0.55

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=)
90
90
CSA

Crest Factor (<=)
1.7
1.7

THD (<=)
25
25

Min. Starting Temp (°F/°C)
50 / 10
50 / 10

UL Listed

T12
Fluorescent Ballasts

Safety and performance

System Watts
180
180

Sign
Ballasts

Fluorescent Accessories
Fluorescent Accessories
Starters

80619
80620
80621
80622
80629
80623
80624
80625
80627
80628

Description

Application

FS-2-C
FS-4-C
FS-5-C
FS-25-C
FS-12-C
BP-SKT
BP
SL-SS
BP-FM
BP-LP

Starters for 14, 15 & 20 Watt Flu. Lamps
Starters for 30 & 40 Watt Flu. Lamps
Starters for 4, 6 & 8 Watt Flu. Lamps
Starters for 22 & 25 Watt Flu. Lamps
Starters for 32 Watt Circular Flu. Lamps
Socket Set w/Starter for Bi-Pin Flu. Lamps
Socket Set for Bi-Pin Flu. Lamps
Socket Set for Slimline Flu. Lamps
Face Mount Socket Set for Bi-Pin Flu. Lamps
Low-Profile Socket Set for Bi-Pin Flu. Lamps

Units Per Carton
24
24
24
24
24
12
12
12
12
12

Compact Fluorescent
Ballasts

Sockets

Prod Code

Quick Reference
Guides

gelighting.com

HID Electronic
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

101

HID Electromagnetic
Ballasts

100

Wiring Diagrams
T12 Fluorescent Ballasts

Wiring Diagrams
T12 Fluorescent Ballasts
LFL 29

LFL 014

LFL 2

LFL 8

LFL 025

LFL 39
T8
Fluorescent Ballasts

LFL 037

Quick Reference
Guides

gelighting.com

T5
Fluorescent Ballasts
T12
Fluorescent Ballasts
Sign
Ballasts
Compact Fluorescent
Ballasts
HID Electronic
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

103

HID Electromagnetic
Ballasts

102

Case Dimensions
T12 Fluorescent Ballasts

Case Dimensions
T12 Fluorescent Ballasts
B1

9

SL

2

10

T8
Fluorescent Ballasts

ST

Quick Reference
Guides

gelighting.com

T5
Fluorescent Ballasts

D10, 15, 29

T12
Fluorescent Ballasts
Sign
Ballasts
Compact Fluorescent
Ballasts
HID Electronic
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

105

HID Electromagnetic
Ballasts

104

Sign Ballasts
For T12 High Output Lamps
Sign Ballasts

T8
Fluorescent Ballasts

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

72103 – GESB-0412-12-IP
T12HO Sign Ballast 4 to 12 ft, 1 to 2 lamps

General characteristics

Understanding Sign Ballasts

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
72103

Lamp

Total Lamp Footage

#
Code GESB Footage lamps

Thermally protected

Pallet Pack

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

F72T12/HO
F96T12/HO

# of Lamps
2
1
1
2
1
2

Line Volts
120
120
120
120
120
120

72103 GESB -0412

-12 IP

F48T12/HO
F24T12/HO

88921 GESB -0620

-24 IP

Safety and performance

88931 GESB -1224

-24 IP

88936 GESB -2040

-24 IP

88920 GESB -1240

-46 IP

88934 GESB -2448

-46 IP

-12 IP

88921 GESB -0620

-24 IP

88931 GESB -1224

-24 IP

88936 GESB -2040

-24 IP

88920 GESB -1240

-46 IP

88934 GESB -2448

-46 IP

Nom. Line Current
1.48 A
0.92 A
1.03 A
1.13 A
0.82 A
0.90 A

UL Type 2 Outdoor

UL Listed

System Ballast Factor
0.89
0.81
0.84
0.85
0.77
0.78
cUL Listed

Ballast Efficacy Factor
0.52
0.81
0.70
0.65
0.96
0.87

Crest Factor (<=)
1.9
2.0
2.0
2.0
2.1
2.1

THD (<=)
15
35
25
20
55
55

Min. Starting Temp (°F/°C)
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29

3-Year Warranty

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

General characteristics

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Magnetic – T12 Sign Illuminating
Rapid start
Series
10%
105°F (41°C)
90°C (194°F)
Normal
Active
Thermally protected

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

Pallet Pack

DIY Pack

IP Pack

11.0 in (279.40 mm)
3.19 in (80.96 mm)
16.00 lbs
Side
Varies
Varies
Length (± 1 in)
24 in (610 mm)
80 in (2032 mm)
60 in (1524 mm)
60 in (1524 mm)
72 in (1829 mm)

Specifications by lamp and wattage

GE Sign Ballast nomenclature

G E S B - 0 6 2 0 - 2 4 - I P
The last number
represents the
number of lamps

10 Pack
72104

11.75 in (298.45 mm)
3.19 in (80.96 mm)
2.6 in (67.86 mm)

Individual pack

# of Lamps
4
3
2

Line Volts
120
120
120

System Watts
300
240
115

Safety and performance

Nom. Line Current
2.56 A
2.34 A
1.41 A

UL Type 2 Outdoor

UL Listed

System Ballast Factor
1.06
0.96
0.87
cUL Listed

Ballast Efficacy Factor
0.35
0.40
0.76

Power Factor % (>=)
95
99
87

Crest Factor (<=)
1.7
1.8
2.0

THD (<=)
15
15
45

Min. Starting Temp (°F/°C)
-20 / -29
-20 / -29
-20 / -29

3-Year Warranty

GESB-2040-46-IP can operate a
minimum of four lamps at a total
length of 20 feet, up to six lamps at
a total length of 40 feet.
106

See page 195 for warranty information.

See page 195 for warranty information.

107

HID Electromagnetic
Ballasts

Examples:
GESB-0620-24-IP can operate a
minimum of two lamps at a total
length of 6 feet, up to four lamps at
a total length of 20 feet.

Lamp
F60T12/HO
F72T12/HO
F36T12/HO

HID Electronic
Ballasts

Wiring diagrams – Sign 0620 – see example on page 118
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Brown and Blue
Orange/Black
Orange, Red and Yellow
Blue/White

Order information

This represents
the min/max
linear footage
of lamps it can
operate.

Power Factor % (>=)
98
92
96
97
84
84

T12HO Sign Ballast 6 to 20 ft, 2 to 4 lamps
1 2 3 4 5 6

The best way to select or provide cross-reference to competition ballasts is to understand the
sign ballast nomenclature.

GE Sign Ballast

8.00 lbs
Side
Varies
Varies
Length (± 1 in)
24 in (610 mm)
80 in (2032 mm)
60 in (1524 mm)
60 in (1524 mm)
72 in (1829 mm)

Compact Fluorescent
Ballasts

72103 GESB -0412

System Watts
170
100
120
130
80
90

Sign Ballasts

# of Lamps

#
Code GESB Footage lamps

11.0 in (279.40 mm)
3.19 in (80.96 mm)

Sign
Ballasts

Description

IP Pack

72104 – GESB-0620-24-IP

Sign Ballast for T12HO, 120 volt
GE

DIY Pack

11.75 in (298.45 mm)
3.19 in (80.96 mm)
2.6 in (67.86 mm)

T12
Fluorescent Ballasts

Description

Wiring diagrams – Sign 0412 – see example on page 117
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Brown and Blue
Orange/Black
Orange, Red and Yellow
Blue/White

Specifications by lamp and wattage

Sign Ballast for T12HO, 120 volt
GE

Magnetic – T12 Sign Illuminating
Rapid start
Series
10%
105°F (41°C)
90°C (194°F)
Normal
Active

T5
Fluorescent Ballasts

GE sign ballasts are transitioning from USB to GESB ballast descriptions. These ballasts are
electromagnetic technology for T12 high output lamps. The sign ballasts are high output
(HO) ballasts for rugged outdoor sign cabinet applications. They will start lamps in cold
temperatures down to -20°F. GE sign ballasts are ideal for high moisture environments with
a UL Type 2 Outdoor and type HL rating. They are 120-volt series rapid start and have Class P
thermal protection.

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Quick Reference
Guides

gelighting.com

Sign Ballasts

Sign Ballasts

For T12 High Output Lamps

For T12 High Output Lamps

Sign Ballasts

Sign Ballasts

T12HO Sign Ballast 12 to 24 ft, 2 to 4 lamps

T12HO Sign Ballast 20 to 40 ft, 4 to 6 lamps

General characteristics

Dimensions
Magnetic –T12 Sign Illuminating
Rapid start
Series
10%
105°F (41°C)
90°C (194°F)
Normal
Active
Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
72105

Pallet Pack

DIY Pack

General characteristics

Wiring diagrams – Sign 1224 – see example on page 118
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Brown and Blue
Orange/Black
Orange, Red and Yellow
Blue/White

IP Pack

11.75 in (298.45 mm)
3.19 in (80.96 mm)
2.6 in (67.86 mm)
11.0 in (279.40 mm)
3.19 in (80.86 mm)
16.00 lbs
Side
Varies
Varies
Length (± 1 in)
24 in (610 mm)
80 in (2032 mm)
60 in (1524 mm)
60 in (1524 mm)
72 in (1829 mm)

Line Volts
120
120
120

System Watts
285
230
170

Safety and performance

UL Listed

System Ballast Factor
0.84
0.82
0.82

Ballast Efficacy Factor
0.29
0.36
0.48

cUL Listed

3-Year Warranty

Class P

Supply Current Frequency

Order information

Power Factor % (>=)
99
96
87

Crest Factor (<=)
1.7
1.8
1.9

THD (<=)
10
15
25

Min. Starting Temp (°F/°C)
-20 / -29
-20 / -29
-20 / -29

F120T12/HO

# of Lamps
4
3
2

Line Volts
120
120
120

System Watts
412
318
225

Nom. Line Current
4.00 A
3.10 A
2.70 A

UL Type 2 Outdoor

UL Listed

System Ballast Factor
0.80
0.82
0.86
cUL Listed

Ballast Efficacy Factor
0.19
0.26
0.38

Power Factor % (>=)
98
95
78

Crest Factor (<=)
1.7
1.8
1.8

THD (<=)
15
10
25

Min. Starting Temp (°F/°C)
-20 / -29
-20 / -29
-20 / -29

3-Year Warranty

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

Sign Ballasts

60 Hz

Order information
IP Pack

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

11.75 in (298.45 mm)
3.19 in (80.96 mm)
2.6 in (67.86 mm)
11.0 in (279.40 mm)
3.19 in (80.96 mm)

Wiring diagrams – Sign 2448 – see example on page 118
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Brown and Blue
Orange/Black
Orange, Red and Yellow
Blue/White

Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
72108

Specifications by lamp and wattage

Pallet Pack

DIY Pack

IP Pack

11.75 in (298.45 mm)
3.19 in (80.96 mm)
2.6 in (67.86 mm)
11.0 in (279.40 mm)
3.19 in (80.96 mm)
18.00 lbs
Side
Varies
Varies
Length (± 1 in)
24 in (610 mm)
80 in (2032 mm)
60 in (1524 mm)
60 in (1524 mm)
72 in (1829 mm)

Specifications by lamp and wattage

Line Volts

System Watts

Nom. Line Current

System Ballast Factor

Ballast Efficacy Factor

Power Factor % (>=)

Crest Factor (<=)

THD (<=)

Min. Starting Temp (°F/°C)

120
120
120
120

415
350
252
183

3.90 A
3.20 A
2.70 A
2.40 A

0.78
0.77
0.78
0.75

0.19
0.22
0.31
0.41

98
95
82
65

1.6
1.7
1.8
1.9

15
10
20
35

-20 / -29
-20 / -29
-20 / -29
-20 / -29

Lamp
F96T12/HO
F72T12/HO

# of Lamps
6
5
5
4

Line Volts
120
120
120
120

System Watts
540
470
370
310

Safety and performance
UL Type 2 Outdoor

UL Listed

cUL Listed

Nom. Line Current
4.50 A
3.50 A
3.20 A
3.00 A

UL Type 2 Outdoor

UL Listed

System Ballast Factor
0.86
0.87
0.89
0.89
cUL Listed

Ballast Efficacy Factor
0.16
0.19
0.24
0.29

Power Factor % (>=)
96
96
92
85

Crest Factor (<=)
1.6
1.7
1.8
1.8

THD (<=)
10
10
10
20

Min. Starting Temp (°F/°C)
-20 / -29
-20 / -29
-20 / -29
-20 / -29

HID Electronic
Ballasts

18.00 lbs
Side
Varies
Varies
Length (± 1 in)
24 in (610 mm)
80 in (2032 mm)
60 in (1524 mm)
60 in (1524 mm)
72 in (1829 mm)

Magnetic – T12 Sign Illuminating
Rapid start
Series
10%
105°F (41°C)
90°C (194°F)
Normal
Active

Compact Fluorescent
Ballasts

Thermally protected

DIY Pack

General characteristics

Wiring diagrams – Sign 1240 – see example on page 118
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Brown and Blue
Orange/Black
Orange, Red and Yellow
Blue/White

Electrical characteristics

3-Year Warranty

3-Year Warranty

See page 195 for warranty information.

See page 195 for warranty information.

109

HID Electromagnetic
Ballasts

108

IP Pack

72108 – GESB-2448-46-IP

Dimensions
Magnetic - T12 Sign Illuminating
Rapid start
Series
10%
105°F (41°C)
90°C (194°F)
Normal
Active

Safety and performance

DIY Pack

18.00 lbs
Side
Varies
Varies
Length (± 1 in)
24 in (610 mm)
80 in (2032 mm)
60 in (1524 mm)
60 in (1524 mm)
72 in (1829 mm)

T12HO Sign Ballast 24 to 48 ft, 4 to 6 lamps

General characteristics

Lamp
# of Lamps
(2) F96T12/HO +
(4) F72T12/HO
6
F72T12/HO
5
F48T12/HO
5
F36T12/HO
4

Lamp

Safety and performance

T12HO Sign Ballast 12 to 40 ft, 4 to 6 lamps

Pallet Pack

Pallet Pack

11.0 in (279.40 mm)
3.19 in (80.96 mm)

Sign
Ballasts

Sign Ballasts

10 Pack
72106

60 Hz

10 Pack
72107

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

72106 – GESB-1240-46-IP

Supply Current Frequency

Thermally protected

11.75 in (298.45 mm)
3.19 in (80.96 mm)
2.6 in (67.86 mm)

Specifications by lamp and wattage
Nom. Line Current
2.70 A
2.10 A
1.60 A

UL Type 2 Outdoor

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagrams – Sign 2040 – see example on page 118
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Brown and Blue
Orange/Black
Orange, Red and Yellow
Blue/White

T12
Fluorescent Ballasts

F72T12/HO

# of Lamps
4
3
2

Magnetic - T12 Sign Illuminating
Rapid start
Series
10%
105°F (41°C)
90°C (194°F)
Normal
Active

Electrical characteristics

Specifications by lamp and wattage
Lamp

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

72107 – GESB-2040-24-IP

T8
Fluorescent Ballasts

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

72105 – GESB-1224-24-IP

Quick Reference
Guides

gelighting.com

Sign Ballasts

Sign Ballasts

For T12 High Output Lamps

For T12 High Output Lamps

Sign Ballasts

Sign Ballasts

4 to 12 ft, 1 to 2 lamps

16 to 32 ft, 2 to 4 lamps

General characteristics

Dimensions
Magnetic – T12 Sign Illuminating
Rapid start
Series
105°F (41°C)
90°C (194°F)
Normal
Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Pallet Pack

DIY Pack

General characteristics

IP Pack

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagrams – Sign S1A, Sign S2A – see example on page 115
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
10.5 in (268.68 mm)
Width (W)
3.19 in (80.96 mm)
Height (H)
1.75 in (44.45 mm)
Mounting dimensions
Bracket Length (BL)
11.7 in (297.25 mm)
Mount Length (M)
11.1 in (282.98 mm)
Mount Width (X or F)
Mount Slots (MS)
Weight
8.00 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
Varies
Remote Mounting Wire Gauge
Varies
Lead lengths
Length (± 1 in)
White and Black
24 in (610 mm)
Blue and Red
38 in (965 mm)
Yellow
48 in (1219 mm)

Magnetic – T12 Sign Illuminating
Rapid start
Series

Wiring diagrams – Sign S4A, Sign S6A, Sign S9 – see example on page 115
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
15.625 in (396.87 mm)
Width (W)
3.19 in (80.96 mm)
Height (H)
2.6 in (67.86 mm)
Mounting dimensions
Bracket Length (BL)
16.6 in (423.87 mm)
Mount Length (M)
16.125 in (409.57 mm)
Mount Width (X or F)
Mount Slots (MS)
Weight
16.00 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
Varies
Remote Mounting Wire Gauge
Varies
Lead lengths
Length (± 1 in)
Blue and Brown
80 in (2032 mm)
Yellow
60 in (1524 mm)
White and Black
24 in (610 mm)
Blue/White
72 in (1829 mm)
Red
54 in (1372 mm)

105°F (41°C)
90°C (194°F)
Normal
Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
88934

Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage
Lamp
F72T12/HO

# of Lamps
2

Line Volts
120

System Watts
160

UL Type 2 Outdoor

UL Type HL

System Ballast Factor
1.00
CSA

Ballast Efficacy Factor
0.62

Power Factor % (>=)
90

Crest Factor (<=)

THD (<=)

Min. Starting Temp (°F/°C)
-20 / -29

Specifications by lamp and wattage
Lamp
F96T12/HO

UL Listed

# of Lamps
4

Line Volts
120

System Watts
420

Safety and performance

Sign Ballasts

105°F (41°C)
90°C (194°F)
Normal
Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Pallet Pack

DIY Pack

IP Pack

Thermally protected

60 Hz

Order information
Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage
Nom. Line Current
1.90 A

System Ballast Factor
1.00

Ballast Efficacy Factor
0.45

Power Factor % (>=)
90

Crest Factor (<=)

THD (<=)

Min. Starting Temp (°F/°C)
-20 / -29

Lamp
F72T12/HO

# of Lamps
4

Line Volts
120

System Watts
325

Safety and performance
UL Type 2 Outdoor

UL Type HL

CSA

Nom. Line Current
2.70 A

UL Type 2 Outdoor

UL Type HL

System Ballast Factor
1.00
CSA

Ballast Efficacy Factor
0.30

Power Factor % (>=)
90

Crest Factor (<=)

THD (<=)

Min. Starting Temp (°F/°C)
-20 / -29

UL Listed

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

111

HID Electromagnetic
Ballasts

110

105°F (41°C)
90°C (194°F)
Normal

HID Electronic
Ballasts

Safety and performance

System Watts
220

Wiring diagrams – Sign S1B, Sign S4A, Sign S6A, Sign S9 – see example on page 115
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
13.19 in (334.96 mm)
Width (W)
3.19 in (80.96 mm)
Height (H)
2.6 in (67.86 mm)
Mounting dimensions
Bracket Length (BL)
14.3 in (363.52 mm)
Mount Length (M)
13.75 in (349.25 mm)
Mount Width (X or F)
Mount Slots (MS)
Weight
14.00 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
Varies
Remote Mounting Wire Gauge
Varies
Lead lengths
Length (± 1 in)
Blue
79 in (2007 mm)
Brown
83 in (2108 mm)
Yellow
75 in (1905 mm)
White and Black
24 in (610 mm)
Red
48 in (1219 mm)
Blue/White
57 in (1448 mm)

Electrical characteristics

Specifications by lamp and wattage
Line Volts
120

Min. Starting Temp (°F/°C)
-20 / -29

Dimensions
Magnetic – T12 Sign Illuminating
Rapid start
Series

Supply Current Frequency

10 Pack
88936

THD (<=)

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Supports 1 to 6 lamps, 2 to 48 feet total length
• Class P thermal protection

General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagrams – Sign S1B, Sign S4A, Sign S6A, Sign S9 – see example on page 115
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
10.5 in (268.68 mm)
Width (W)
3.19 in (80.96 mm)
Height (H)
2.6 in (67.86 mm)
Mounting dimensions
Bracket Length (BL)
11.7 in (297.25 mm)
Mount Length (M)
11.1 in (282.98 mm)
Mount Width (X or F)
Mount Slots (MS)
Weight
12.00 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
Varies
Remote Mounting Wire Gauge
Varies
Lead lengths
Length (± 1 in)
White and Black
24 in (610 mm)
Blue
65 in (1651 mm)
White
36 in (914 mm)
Yellow
39 in (991 mm)
Brown
56 in (1422 mm)
Red
40 in (1016 mm)
Blue/White
48 in (1219 mm)

Crest Factor (<=)

Compact Fluorescent
Ballasts

Magnetic – T12 Sign Illuminating
Rapid start
Series

Power Factor % (>=)
90

UL Listed

Sign Ballasts

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

# of Lamps
4

CSA

10 to 24 ft, 1 to 4 lamps

General characteristics

Lamp
F48T12/HO

UL Type HL

Ballast Efficacy Factor
0.23

88936 – USB-1024-14-IP

8 to 16 ft, 1 to 4 lamps

10 Pack
88931

UL Type 2 Outdoor

System Ballast Factor
1.00

Sign
Ballasts

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

88931 – USB-0816-14-IP

Nom. Line Current
3.50 A

T12
Fluorescent Ballasts

Safety and performance

Nom. Line Current
1.35 A

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

10 Pack
88921

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

88934 – USB-1632-24-IP

T8
Fluorescent Ballasts

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

88921 – USB-0412-12-IP

Quick Reference
Guides

gelighting.com

Sign Ballasts

Sign Ballasts

For T12 High Output Lamps

For T12 High Output Lamps

Sign Ballasts
20 to 36 ft, 4 to 6 lamps

General characteristics
Magnetic – T12 Sign Illuminating
Rapid start
Series

Max 3, 2 to 18 ft, 1 to 6 lamps

Electrical characteristics
60 Hz

Order information
Pallet Pack

DIY Pack

IP Pack

Line Volts
120

System Watts
480

Electrical characteristics
Order information
10 Pack
88918

Nom. Line Current
4.00 A

System Ballast Factor
1.00

Ballast Efficacy Factor
0.20

UL Type 2 Outdoor

UL Type HL

CSA

Power Factor % (>=)
90

Crest Factor (<=)

THD (<=)

Min. Starting Temp (°F/°C)
-20 / -29

General characteristics

Thermally protected

Electrical characteristics
60 Hz

Order information

System Watts
240

Pallet Pack

DIY Pack

UL Type 2 Outdoor

UL Type HL

System Ballast Factor
1.00
CSA

Ballast Efficacy Factor
0.41

Power Factor % (>=)
90

Crest Factor (<=)

THD (<=)

Min. Starting Temp (°F/°C)
-20 / -29

UL Listed

IP Pack

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

General characteristics

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Magnetic – T12 Sign Illuminating
Rapid start
Series

Wiring diagrams – Sign S1, Sign S2, Sign S3, Sign S4, Sign S7, Sign S8 – see example on pages 116-117
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
15.625 in (396.87 mm)
Width (W)
3.19 in (80.96 mm)
Height (H)
2.6 in (67.86 mm)
Mounting dimensions
Bracket Length (BL)
16.6 in (423.87 mm)
Mount Length (M)
16.125 in (409.57 mm)
Mount Width (X or F)
Mount Slots (MS)
Weight
18.00 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
Varies
Remote Mounting Wire Gauge
Varies
Lead lengths
Length (± 1 in)
Blue and Red
80 in (2032 mm)
Blue/White and Brown
50 in (1270 mm)
Yellow
70 in (1778 mm)
White and Black
24 in (610 mm)
Orange/Black and Orange
60 in (1524 mm)

105°F (41°C)
90°C (194°F)
Normal
Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
88919

Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage
Nom. Line Current
5.00 A

System Ballast Factor
1.00

Ballast Efficacy Factor
0.16

Power Factor % (>=)
90

Crest Factor (<=)

THD (<=)

Min. Starting Temp (°F/°C)
-20 / -29

Lamp
F96T12/HO

# of Lamps
6

Line Volts
120

System Watts
570

Safety and performance
UL Type 2 Outdoor

UL Type HL

CSA

Nom. Line Current
4.80 A

UL Type 2 Outdoor

UL Type HL

System Ballast Factor
1.00
CSA

Ballast Efficacy Factor
0.17

Power Factor % (>=)
90

Crest Factor (<=)

THD (<=)

Min. Starting Temp (°F/°C)
-20 / -29

UL Listed

HID Electronic
Ballasts

System Watts
600

Nom. Line Current
2.00 A

Max 3, 10 to 48 ft, 1 to 6 lamps

Specifications by lamp and wattage

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

113

HID Electromagnetic
Ballasts

112

Line Volts
120

Sign Ballasts

Wiring diagrams – Sign S5A, Sign S7, Sign S7A – see example on pages 116-117
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
15.625 in (396.87 mm)
Width (W)
3.19 in (80.96 mm)
Height (H)
2.6 in (67.86 mm)
Mounting dimensions
Bracket Length (BL)
16.6 in (423.87 mm)
Mount Length (M)
16.125 in (409.57 mm)
Mount Width (X or F)
Mount Slots (MS)
Weight
18.00 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
Varies
Remote Mounting Wire Gauge
Varies
Lead lengths
Length (± 1 in)
Blue/White
50 in (1270 mm)
Brown and Orange
50 in (1270 mm)
Orange/Black
50 in (1270 mm)
White and Black
24 in (610 mm)
Blue and Red
80 in (2032 mm)
Yellow
70 in (1778 mm)

105°F (41°C)
90°C (194°F)
Normal

Safety and performance

# of Lamps
6

Compact Fluorescent
Ballasts

Magnetic – T12 Sign Illuminating
Rapid start
Series

Line Volts
120

Lamp
F36T12/HO

88919 – USB-1048-16-IP

Dimensions

Supply Current Frequency

IP Pack

Sign
Ballasts

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL type 2 outdoor and HL rating
• Supports 1 to 6 lamps, 2 to 48 feet total length
• Class P thermal protection

20 to 48 ft, 4 to 6 lamps
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

DIY Pack

UL Listed

Sign Ballasts

# of Lamps
6

Pallet Pack

Specifications by lamp and wattage

88940 – USB-2048-46-IP

Lamp
F96T12/HO

60 Hz

Safety and performance

Safety and performance

10 Pack
88940

Thermally protected

T12
Fluorescent Ballasts

# of Lamps
6

Wiring diagrams – Sign S3, Sign S4, Sign S5, Sign S6, Sign S7, Sign S8 – see example on pages 116-117
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
13.19 in (334.96 mm)
Width (W)
3.19 in (80.96 mm)
Height (H)
2.6 in (67.86 mm)
Mounting dimensions
Bracket Length (BL)
14.3 in (363.52 mm)
Mount Length (M)
13.75 in (349.25 mm)
Mount Width (X or F)
Mount Slots (MS)
Weight
15.00 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
Varies
Remote Mounting Wire Gauge
Varies
Lead lengths
Length (± 1 in)
White and Black
24 in (610 mm)
Brown, Blue and Red
60 in (1524 mm)
Orange/Black
60 in (1524 mm)
Orange and Yellow
60 in (1524 mm)
Blue/White
60 in (1524 mm)

105°F (41°C)
90°C (194°F)
Normal

Supply Current Frequency

Specifications by lamp and wattage
Lamp
F72T12/HO

Dimensions
Magnetic – T12 Sign Illuminating
Rapid start
Series

T5
Fluorescent Ballasts

Thermally protected

Supply Current Frequency

General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Wiring diagrams – Sign S5A, Sign S7, Sign S7A – see example on pages 116-117
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
15.625 in (396.87 mm)
Width (W)
3.19 in (80.96 mm)
Height (H)
2.6 in (67.86 mm)
Mounting dimensions
Bracket Length (BL)
16.6 in (423.87 mm)
Mount Length (M)
16.125 in (409.57 mm)
Mount Width (X or F)
Mount Slots (MS)
Weight
18.00 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
Varies
Remote Mounting Wire Gauge
Varies
Lead lengths
Length (± 1 in)
Orange and Blue
50 in (1270 mm)
Orange/Black
50 in (1270 mm)
Red
80 in (2032 mm)
Yellow
70 in (1778 mm)
Blue/White and Brown
38 in (965 mm)
White and Black
24 in (610 mm)

105°F (41°C)
90°C (194°F)
Normal

10 Pack
88939

Sign Ballasts

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

88918 – USB-0218-16-IP

T8
Fluorescent Ballasts

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Supports 1 to 6 lamps, 2 to 48 feet total length
• Class P thermal protection

88939 – USB-2036-46-IP

Quick Reference
Guides

gelighting.com

Sign Ballasts

Wiring Diagrams
Sign Ballasts

For T12 High Output Lamps
Sign Ballasts

SIGN S1A

SIGN S2A

SIGN S1B

SIGN S4A

SIGN S6A

SIGN S9

T8
Fluorescent Ballasts

• High-output ballasts for rugged outdoor sign cabinet applications
• Reliable low-temperature starting – as low as -20°F
• Ideal for high-moisture environments – UL Type 2 Outdoor and HL rating
• Class P thermal protection

88920 – USB-1232-16-IP
Max 3, 12 to 32 ft, 1 to 6 lamps

General characteristics

Dimensions
Magnetic – T12 Sign Illuminating
Rapid start
Series

Wiring diagrams – Sign S3, Sign S4, Sign S5, Sign S6, Sign S7, Sign S8 – see example on pages 116-117
Case dimensions – Ref Drawing S1 – see page 119
Length (L)
13.19 in (334.96 mm)
Width (W)
3.19 in (80.96 mm)
Height (H)
2.6 in (67.86 mm)
Mounting dimensions
Bracket Length (BL)
14.3 in (363.52 mm)
Mount Length (M)
13.75 in (349.25 mm)
Mount Width (X or F)
Mount Slots (MS)
Weight
16.00 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
Varies
Remote Mounting Wire Gauge
Varies
Lead lengths
Length (± 1 in)
White and Black
24 in (610 mm)
Brown and Blue
80 in (2032 mm)
Orange/Black
60 in (1524 mm)
Orange, Red and Yellow
60 in (1524 mm)
Blue/White
72 in (1829 mm)

105°F (41°C)
90°C (194°F)
Normal
Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
88920

Pallet Pack

DIY Pack

IP Pack

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
# of Lamps
6

Line Volts
120

Safety and performance

System Watts
410

Nom. Line Current
3.50 A

UL Type 2 Outdoor

UL Type HL

System Ballast Factor
1.00
CSA

Ballast Efficacy Factor
0.24

Power Factor % (>=)
90

Crest Factor (<=)

THD (<=)

Min. Starting Temp (°F/°C)
-20 / -29

UL Listed

T12
Fluorescent Ballasts

Lamp
F48T12/HO

Quick Reference
Guides

gelighting.com

Sign
Ballasts
Compact Fluorescent
Ballasts
HID Electronic
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

115

HID Electromagnetic
Ballasts

114

Wiring Diagrams
Sign Ballasts
SIGN S5A

Wiring Diagrams
Sign Ballasts
SIGN S7A

SIGN S6

SIGN S7

SIGN S8

T8
Fluorescent Ballasts

SIGN S5

Quick Reference
Guides

gelighting.com

T5
Fluorescent Ballasts

SIGN S3

SIGN S4

Sign
Ballasts

SIGN S2

T12
Fluorescent Ballasts

SIGN S1

Compact Fluorescent
Ballasts

SIGN 0412
LINE

BLACK
WHITE

Ballast

RED
RED

LINE

BLACK
WHITE

Ballast

YELLOW
YELLOW

BLUE
BLUE

HID Electronic
Ballasts

YELLOW
YELLOW

BLUE
BLUE

RED
RED

Lamp 1
Lamp 2

See page 195 for warranty information.

See page 195 for warranty information.

117

HID Electromagnetic
Ballasts

116

Lamp 1

Wiring Diagrams
Sign Ballasts

Case Dimensions
Sign Ballasts

SIGN 0620

S1
BLUE
BLUE

Ballast

BLACK
WHITE

LINE

BLUE
BLUE

Ballast

BLACK
WHITE

LINE

T8
Fluorescent Ballasts

BLACK
WHITE

LINE

BLUE
BLUE

Ballast

BROWN
BROWN

BLUE/WHITE
BLUE/WHITE

BROWN
BROWN

BLUE/WHITE
BLUE/WHITE

BROWN
BROWN

BLUE/WHITE
BLUE/WHITE

YELLOW
YELLOW

RED
RED

YELLOW
YELLOW

RED
RED

YELLOW
YELLOW

RED
RED

Lamp 1
Lamp 1

Lamp 2

Lamp 1

Lamp 2

Lamp 3

Lamp 2

Lamp 3

Lamp 4

T5
Fluorescent Ballasts

SIGN 1224
BLACK
WHITE

LINE

BLUE
BLUE

Ballast

BLACK
WHITE

LINE

BLUE
BLUE

Ballast

BLACK
WHITE

LINE

BLUE
BLUE

Ballast

BROWN
BROWN

BLUE/WHITE
BLUE/WHITE

BROWN
BROWN

BLUE/WHITE
BLUE/WHITE

BROWN
BROWN

BLUE/WHITE
BLUE/WHITE

YELLOW
YELLOW

RED
RED

YELLOW
YELLOW

RED
RED

YELLOW
YELLOW

RED
RED

Quick Reference
Guides

gelighting.com

Lamp 1
Lamp 2

Lamp 2

Lamp 3

Lamp 2

Lamp 3

Lamp 4

T12
Fluorescent Ballasts

Lamp 1
Lamp 1

SIGN 1240
LINE

BLACK
WHITE
BROWN
BROWN

Ballast

BLUE
BLUE

LINE

BLACK
WHITE

OR BLK
OR BLK

BROWN
BROWN

BLUE WH
BLUE WH

ORAN E
ORAN E

YELLOW
YELLOW

RED
RED

Ballast

BLUE
BLUE

LINE

BLACK
WHITE

Ballast

BLUE
BLUE

OR BLK
OR BLK

BROWN
BROWN

BLUE WH
BLUE WH

ORAN E
ORAN E

BLUE WH
BLUE WH

ORAN E
ORAN E

YELLOW
YELLOW

RED
RED

YELLOW
YELLOW

RED
RED

Lamp 1

Lamp 1

Lamp 2

Lamp 2

Lamp 3

Lamp 3

Lamp 3

Lamp 4

Lamp 4

Lamp

Lamp

Lamp

Sign
Ballasts

Lamp 1

OR BLK
OR BLK

Lamp 2

Lamp 4

Compact Fluorescent
Ballasts

SIGN 2040
BLACK
WHITE

LINE

Ballast

BLUE
BLUE

LINE

BLACK
WHITE

Ballast

BLUE
BLUE

LINE

BLACK
WHITE

Ballast

BLUE
BLUE

BROWN
BROWN

BLUE/WHITE
BLUE/WHITE

BROWN
BROWN

BLUE/WHITE
BLUE/WHITE

BROWN
BROWN

BLUE/WHITE
BLUE/WHITE

YELLOW
YELLOW

RED
RED

YELLOW
YELLOW

RED
RED

YELLOW
YELLOW

RED
RED

Lamp 1
Lamp 1

Lamp 2

Lamp 2

Lamp 3

Lamp 3

Lamp 4

HID Electronic
Ballasts

Lamp 2

Lamp 1

SIGN 2448
LINE

BLACK
WHITE
BROWN
BROWN

Ballast

BLUE
BLUE

LINE

BLACK
WHITE

OR BLK
OR BLK

BROWN
BROWN

BLUE WH
BLUE WH

ORAN E
ORAN E

YELLOW
YELLOW

RED
RED

Ballast

BLUE
BLUE

LINE

BLACK
WHITE

Ballast

BLUE
BLUE

OR BLK
OR BLK

BROWN
BROWN

BLUE WH
BLUE WH

ORAN E
ORAN E

BLUE WH
BLUE WH

ORAN E
ORAN E

YELLOW
YELLOW

RED
RED

YELLOW
YELLOW

RED
RED

Lamp 1

Lamp 1

Lamp 2

Lamp 2

Lamp 3

Lamp 3

Lamp 3

Lamp 4

Lamp 4

Lamp

Lamp

Lamp

Lamp 2

Lamp 4

118

See page 195 for warranty information.

See page 195 for warranty information.

119

HID Electromagnetic
Ballasts

Lamp 1

OR BLK
OR BLK

GE Multivolt ProLine® CFL Multi-Lamp Capability

GE compact fluorescent (CFL) ballasts provide energy saving alternatives to halogen,
incandescent or HID light sources. GE Multivolt ProLine® CFL programmed start ballasts
combine universal voltage (108-305V) technology with multi-lamp capability, dual entry
color-coded connectors and ultra system reliability to create an industry leading CFL solution
for commercial and residential applications.

T5 Circleline

FT TT5

Multivolt ProLine® CFL ballasts come with a five-year ballast and one-year lamp limited
warranty. These ballasts also meet the EPA’s ENERGY STAR® fixture program requirements
with a Consumer Class B EMI rating for residential applications, as well as a high power factor
ballast design.

T5

GEC242MVPS

X
X
X

X
X

X

X

GEC240-MV

X
X
X
X
X
X
X
X
X
X
X
X

X
X

X
X
X
X
X
X
X

X
X
X
X
X
X

CFL – Cross Reference Chart
Universal

Advance

Osram

Robertson

ESI

GE213-MVPS-3W

C213UNVSE/BE/BES

ICF-2513-H1-LD

QTP 1/2X13CF/UNV

PSM213CQMY

ES-2/1-CFQ-13/10-UNV-C/D
ES-1-2D-16/10-UNV-D

GE218-MVPS-3W

C218UNVSE/BE/BES

ICF-2518-H1-LD
REL-2Q18
VEL-2Q18
R-2Q18-4P-TP
V-2Q18-4P-TP

QTP 1/2X18CF/UNV

PSM218CQMY

ES-2/1-CFQ-18-UNV-C/D
ES-1-2D-21-UNV-D

GE226-MVPS-3W

C2642UNVSE/BE/BES
C226SR120BE
C226SR277BE

ICF-2526-H1-LD
REL-1T32
VEL-1T32
REL-1T42
VEL-1T42

QTP 2X26/UNV
QTP 1/2XCF/UNV

PSM226CQMY

ES-2/1-CFQ-26-UNV-C/D
ES-1-CFH-42/32/26-UNV-C/D
ES-1-T5C-40/22-UNV-D

HID Electronic
Ballasts

GE Compact Fluorescent Ballast nomenclature

G E C 2 1 3 - M V P S - S E
GE Compact
Ballast

120

SE = Side & Bottom Entry
BES = Bottom Entry with Studs
3W = 3-Way Kit (SE, BE, BES)
IP = Individual Pack

PS = Programmed Start
SI = Series Instant Start
PH = Preheat.
RS = Rapid Start
RH = less than 20% THD
See page 195 for warranty information.

See page 195 for warranty information.

121

HID Electromagnetic
Ballasts

Max number
of lamps and
Primary Lamp
type

MV = Multivolt
(108 to 305 volts)
UNV = Universal Voltage
(Multi-Voltage)
120 or 277 = voltage

Compact Fluorescent
Ballasts

GE

Sign
Ballasts

Use the GE Multivolt ProLine® CFL Multi-Lamp compatibility chart (page 121) to find the right
ballast for your need.

2D

X
X
X

GEC226-MVPS

T12
Fluorescent Ballasts

Multivolt ProLine® CFL ballasts are offered in three different configurations:
1) -SE description – dual entry (side or bottom) connectors, 2) -BES – bottom entry with studs for
mounting to junction boxes and 3) -3W – 3-way mounting kits that allow you to have all three
mounting options with one kit.

GEC218-MVPS

T5
Fluorescent Ballasts

Understanding
Compact Fluorescent Ballasts

GEC213-MVPS
X
X
X

T8
Fluorescent Ballasts

T4

Lamp Type
1 x 13W (CFQ/G24q, CFTR/GX24q)
2 x 13W (CFQ/G24q, CFTR/GX24q)
1 x 18W (CFQ/G24q, CFTR/GX24q)
2 x 18W (CFQ/G24q, CFTR/GX24q)
1 x 26W (CFQ/G24q, CFTR/GX24q)
2 x 26W (CFQ/G24q, CFTR/GX24q)
1 x 32W (CFQ/G24q, CFTR/GX24q)
2 x 32W (CFQ/G24q, CFTR/GX24q)
1 x 42W (CFQ/G24q, CFTR/GX24q)
2 x 42W (CFQ/G24q, CFTR/GX24q)
1 x 22W (FC9T5)
1 x 22W (FC9T5)
1 x 22W + 1 x 40W (FC9T5 + FC12T5)
1 x FC16T9
2 x 24 / 27W (FT/2G11)
1 x FT36W (2G11)
2 x FT36W (2G11)
1 x 40W (FT/2G11) & Energy Saving 28W
2 x 40W (FT/2G11) & Energy Saving 28W
3 x 40W (FT/2G11) & Energy Saving 28W
1 x 10W (CFS/GR10q)
2 x 10W (CFS/GR10q)
1 x 16W (CFS/GR10q)
2 x 16W (CFS/GR10q)
1 x 21W (CFS/GR10q)
2 x 21W (CFS/GR10q)
1 x 28W (CFS/GR10q)
2 x 28W (CFS/GR10q)
1 x 38W (CFS/GR10q)
2 x 38W (CFS/GR10q)
1 x 57W (CFTR/GX24q)
1 x 70W (CFTR/GX24q)

Quick Reference
Guides

gelighting.com

ProLine® CFL Electronic Ballasts

Specifications: Multivolt ProLine® CFL Quick Reference Chart

Lamp Type

CFTR13W/GX24q
CFQ18W/GX24q
CFTR18W/GX24q

GEC213-MVPS-xx

CFS16W/GR10q

CFTR18W/GX24q
CFQ26W/G24q
GFTR26W/GX24q

CFS16W/GR10q
GEC218-MVPS-xx

CFS28W/GR10q

CFTR26W/GX24q
CFTR42W/GX24q
CFT32W/GX24q

FT24W/2G11
GEC226-MVPS-xx

FC16T9/40W

ProLine® CFL Electronic Ballasts
2 or 1 – CFQ13W/G24q 120-227V ProLine® PS

General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Supply Current Frequency

50 Hz/60 Hz

5.0 in (127.00 mm)
2.4 in (60.96 mm)
1.0 in (25.40 mm)
4.63 in (117.60 mm)
2.4 in (60.96 mm)
0.57 lbs
Dual Entry (SE/BE, BES, 3W)
20 ft
18 AWG

Order information
10 Pack
71428, 71429, 71430

Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage
Lamp

# of Lamps
Line Volts
System Watts
Nom. Line Current
System Ballast Factor
2
120
31
0.26 A
1.00
2
277
31
0.12 A
1.00
2
120
30
0.25 A
1.00
F13T5
2
277
30
0.11 A
1.00
2
120
29
0.25 A
1.00
2
277
29
0.11 A
1.00
CFTR13W/
1
120
16
0.16 A
1.00
1
277
16
0.06 A
1.00
GX24q
2
120
29
0.25 A
1.00
2
277
29
0.11 A
1.00
1
120
16
0.16 A
1.00
CFQ13W/G24q
1
277
16
0.06 A
1.00
Other compatible lamps: CFQ18W/G24q, CFTR18W/GX24q, CFS16W/GR10q, CFS10W/GR10q
F14T5

Safety and performance

UL Type 1 Outdoor FCC Part 18 Class B at 120 Volts

Ballast Efficacy Factor
3.23
3.23
3.33
3.33
3.45
3.45
6.25
6.25
3.45
3.45
6.25
6.25

UL Type HL

Power Factor % (>=)
99
98
99
98
99
99
96
96
99
99
96
96

FCC – CLASS B Consumer

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Class P

CSA

THD (<=)
10
10
10
10
10
10
10
10
10
10
10
10

Min. Starting Temp (°F/°C)
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29

UL Type CC

UL Listed

• Multi-voltage technology means a single ballast handles voltage from 108V to 305V
• Programmed starting for extended lamp life
• End-of-Lamp-Life protection
• Color coded poke-in connectors simplifies wiring

71432 – GEC218-MVPS-BES
71433 – GEC218-MVPS-SE
71434 – GEC218-MVPS-3W
ProLine® CFL Electronic Ballasts
2 or 1 – CFQ18W/G24q 120-227V ProLine® PS

Dimensions

General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Electronic – Program / Rapid start
Programmed start
Series
10%
104°F (40°C)
70°C (158 °F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected, Universal voltage

Wiring diagram – CFL 1-2 – see example on page 132
Case dimensions – Ref Drawing -13 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge

Electrical characteristics
Supply Current Frequency

50 Hz/60 Hz

5.0 in (127.00 mm)
2.4 in (60.96 mm)
1.0 in (25.40 mm)
4.63 in (117.60 mm)
2.4 in (60.96 mm)
1.10 lbs
Dual Entry (SE/BE, BES, 3W)
20 ft
18 AWG

Order information
10 Pack
71432, 71433, 71434

Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage
Lamp

# of Lamps
Line Volts
System Watts
Nom. Line Current
System Ballast Factor
2
120
40
0.33 A
0.91
2
277
40
0.14 A
0.91
CFS21W/
1
120
20
0.16 A
0.9
GR10q
1
277
20
0.07 A
0.9
2
120
39
0.33 A
1.05
2
277
39
0.14 A
1.05
CFTR18W/
1
120
20
0.17 A
1.05
GX24q
1
277
20
0.08 A
1.05
CFS16W/
2
120
37
0.31 A
1.00
2
277
37
0.13 A
1.00
GR10q
Other compatible lamps: CFTR26W/GX24q, CFQ26W/G24q, CFS28W/GR10q, CFQ18W/G24q

See page 195 for warranty information.

UL Type 1 Outdoor FCC Part 18 Class B at 120 volts

Ballast Efficacy Factor
2.28
2.28
4.50
4.50
2.69
2.69
5.25
5.25
2.70
2.70

FCC – CLASS B Consumer

Power Factor % (>=)
99
99
97
97
97
97
97
97
99
99

UL Type HL

UL Class P

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

CSA

THD (<=)
10
10
15
15
10
10
10
10
10
10

UL Type CC

Min. Starting Temp (°F/°C)
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29

UL Listed

123

HID Electromagnetic
Ballasts

See page 195 for warranty information.

Wiring diagram – CFL 1-2 – see example on page 132
Case dimensions – Ref Drawing -13 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge

Electrical characteristics

Safety and performance
122

Dimensions
Electronic – Program / Rapid Start
Programmed start
Series
10%
104°F (40°C)
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
End-of-Life Protection (EOL), Thermally protected,
Universal voltage

HID Electronic
Ballasts

CFS21W/GR10q

• Multi-voltage technology means a single ballast handles voltage from 108V to 305V
• Programmed starting for extended lamp life
• End-of-Lamp-Life protection
• Color coded poke-in connectors simplifies wiring

71428 – GEC213-MVPS-BES
71429 – GEC213-MVPS-SE
71430 – GEC213-MVPS-3W

Compact Fluorescent
Ballasts

CFQ26W/G24q

For 13 – 42W T4 CFL Lamps

Sign
Ballasts

CFS21W/GR10q

Ballast
Efficiency
Factor
3.45
3.45
6.25
6.25
3.45
3.45
6.25
6.25
5.00
5.00
5.00
5.00
4.13
4.13
8.08
8.08
5.88
5.88
2.71
2.71
5.26
5.26
2.69
2.69
5.25
5.25
3.57
3.57
3.57
3.57
2.28
2.28
4.5
4.5
2.70
2.70
3.23
3.23
1.96
1.96
3.7
3.7
1.85
1.85
3.79
3.79
2.13
2.13
2.72
2.72
2.20
2.20
1.94
1.94
2.33
2.33

T12
Fluorescent Ballasts

GFQ18W/G24q

Max THD%
10
10
10
10
10
10
10
10
12
12
12
12
11
11
14
14
12
12
10
10
10
10
10
10
10
10
12
12
12
12
10
10
15
15
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10

Ballast
Factor
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
0.95
0.95
1.05
1.05
1.0
1.0
0.95
0.95
1.0
1.0
1.05
1.05
1.05
1.05
1.0
1.0
1.0
1.0
0.91
0.91
0.9
0.9
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.10
1.10
0.98
0.98
0.98
0.98
1.12
1.12
0.93
0.93
1.00
1.00

T5
Fluorescent Ballasts

CFS10W/GR10q

Power
Factor
0.99
0.99
0.96
0.96
0.99
0.99
0.96
0.96
0.99
0.97
0.99
0.97
0.97
0.97
0.96
0.96
0.96
0.96
0.99
0.99
0.97
0.97
0.97
0.99
0.97
0.97
0.99
0.96
0.99
0.96
0.99
0.99
0.97
0.97
0.99
0.99
0.99
0.97
0.99
0.99
0.98
0.98
0.99
0.99
0.98
0.98
0.98
0.98
0.98
0.98
0.99
0.99
0.99
0.99
0.99
0.97

T8
Fluorescent Ballasts

CFQ13W/GX4q

SE
BES
3W
(Side and (Bottom (3-Way
Bottom Exit with Mounting
# of Lamps Input Volts Entry)
Studs)
Kit)
Input Watts Line Current
120
29
0.25
2
277
29
0.11
120
16
0.16
1
177
16
0.06
120
29
0.25
2
277
29
0.11
120
16
0.16
1
277
16
0.06
120
20
0.17
1
277
20
0.07
120
20
0.17
1
277
20
0.07
120
23
0.19
2
277
23
0.09
120
13
0.11
1
277
13
0.05
120
17
0.14
1
277
17
0.06
71429
71428
71430
35
0.3
120
277
35
0.13
2
120
19
0.16
1
277
19
0.07
120
39
0.33
2
277
39
0.14
120
20
0.17
1
277
20
0.08
120
28
0.24
1
277
28
0.10
120
28
0.24
1
277
28
0.10
120
40
0.33
2
277
40
0.14
120
20
0.16
1
277
20
0.07
120
37
0.31
2
277
37
0.13
120
31
0.26
1
277
31
0.11
71433
71432
71434
120
51
0.43
2
277
51
0.19
120
27
0.23
1
277
27
0.10
120
54
0.45
2
277
54
0.20
120
29
0.24
1
277
29
0.11
120
46
0.38
1
277
46
0.17
120
36
0.031
1
277
36
0.013
120
51
0.042
2
277
51
0.18
120
48
0.41
2
277
48
0.18
120
43
0.36
71444
71443
71445
1
277
43
0.16

Quick Reference
Guides

gelighting.com

ProLine® CFL Electronic Ballasts

ProLine® CFL Electronic Ballasts

For 13 – 42W T4 CFL Lamps

For 40W Biax® CFL Ballasts

ProLine CFL Electronic Ballasts

General characteristics

General characteristics

Dimensions
Wiring diagram – CFL 1-2 – see example on page 132
Case dimensions – Ref Drawing 13 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge

Electrical characteristics
50 Hz/60 Hz

5.0 in (127.00 mm)
2.4 in (60.96 mm)
1.0 in (25.40 mm)

Electronic – Program / Rapid Start
Programmed start
Series
10%
105°F (41°C)
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected, Universal voltage

Wiring diagram – CFL 20C – see example on page 131
Case dimensions – Ref Drawing -B – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue and Red
Yellow
White

Electrical characteristics

4.63 in (117.60 mm)
2.4 in (60.96 mm)

Supply Current Frequency

0.57 lbs
Dual Entry (SE/BE, BES, 3W)
12 ft
18 AWG

50 Hz /60 Hz

Order information
10 Pack
80683

Pallet Pack

DIY Pack

IP Pack

Order information
10 Pack
71443, 71444, 71445

Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage

Safety and performance

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
1.00
1.00
1.10
1.10
1.00
1.00
1.00
1.00
0.98
0.98
98.00
0.98

FCC – CLASS B Consumer

Ballast Efficacy Factor
1.85
1.85
3.79
3.79
1.96
1.96
3.70
3.70
2.13
2.13
272.22
2.72

Power Factor % (>=)
99
99
98
98
99
99
98
98
98
98
98
98

FCC Part 18 Class B at 120 volts

Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

UL Class P

THD (<=)
10
10
10
10
10
10
10
10
10
10
10
10

UL Type CC

Min. Starting Temp (°F/°C)
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29
-20/-29

UL Listed

Safety and performance

Nom. Line Current
0.63 A
0.26 A
0.34 A
0.15 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.90
0.90
1.00
1.00

Ballast Efficacy Factor
1.18
1.23
2.43
2.50

FCC – CLASS A Non-Consumer

UL Listed

Sign
Ballasts

50 Hz/60 Hz

Wiring diagram – CFL 5 – see example on page 132
Case dimensions – Ref Drawing 13 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge

4.3 in (107.95 mm)
3.0 in (75.69 mm)
1.0 in (25.40 mm)
4.9 in (125.47 mm)
4.6 in (117.09 mm)
1.6 in (39.37 mm)

Electronic – Standard Instant Start
Instant start
Series
10%
105°F (41°C)
70 °C (158 °F)
Normal
Passive
A (20-24 decibels)
End-of-Life Protection (EOL), Thermally protected

Electrical characteristics
Supply Current Frequency

0.90 lbs
Bottom/Side
12 ft
18 AWG

50 Hz /60 Hz

Order information
10 Pack
80680

Pallet Pack

DIY Pack

IP Pack

Order information
DIY Pack

IP Pack

Specifications by lamp and wattage
Lamp

FCC – CLASS A Non Consumer

FCC Part 18 Class B at 120 volts

Crest Factor (<=)
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

UL Class P

THD (<=)
10
10
10
10
10
10
10
10

UL Type CC

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18

UL Listed

FT40W/4P

# of Lamps
2
1

Line Volts
120
120

System Watts
67
40

Safety and performance

Nom. Line Current
0.61 A
0.40 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.88
1.02

Ballast Efficacy Factor
1.31
2.55

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=)
95
90
CSA

Crest Factor (<=)
1.7
1.7

THD (<=)
20
20

Min. Starting Temp (°F/°C)
50 / 10
50 / 10

UL Listed

CSA

See page 195 for warranty information.

See page 195 for warranty information.

125

HID Electromagnetic
Ballasts

# of Lamps Line Volts
System Watts
Nom. Line Current
System Ballast Factor Ballast Efficacy Factor
Power Factor % (>=)
2
120
91
0.76 A
0.98
1.08
98
2
277
90
0.32 A
0.98
1.09
98
1
120
45
0.40 A
1.00
2.22
93
CFTR42W/4P
1
277
45
0.18 A
1.00
2.22
93
1
120
69
0.58 A
1.00
1.45
98
CFTR32W/4P
1
277
67
0.26 A
1.00
1.49
98
2
120
56
0.46 A
1.02
1.82
95
CFTR26W/4P
2
277
65
0.20 A
1.02
1.85
95
Other compatible lamps: FT55W/4P, FT36W/4P, FT24W/4P, FC9T522W/4P, FC12T555W/4P, FC12T540W/4P, CFTR70W/4P, CFTR57W/4P, CFS28W/4P, CFM3W/4P
UL Type HL

9.5 in (241.30 mm)
8.8 in (225.80 mm)
1.6 in (42.87 mm)
0.3 in (7.92 mm)
2.70 lbs
Side
12 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
33 in (838 mm)
25 in (635 mm)
25 in (635 mm)

Specifications by lamp and wattage
Lamp

UL Type 1 Outdoor

8.3 in (211.07 mm)
2.4 in (60.96 mm)
1.5 in (39.37 mm)

HID Electronic
Ballasts

Wiring diagram – CFL 1B – see example on page 131
Case dimensions – Ref Drawing C6 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
Red
White
Black

Compact Fluorescent
Ballasts

Electrical characteristics

124

Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Dimensions
Electronic – Program / Rapid start
Programmed start
Series
10%
122°F (50°C)
75°C (167°F)
Normal
Active
A (20-24 decibels)
Auto restart, Thermally protected, Universal voltage

Safety and performance

THD (<=)
10
10
10
10

• Electronic compact fluorescent ballasts for all general fluorescent applications
• Low-profile case

General characteristics

General characteristics

Pallet Pack

CSA

Crest Factor (<=)
1.5
1.5
1.5
1.5

2 – FT40W/2G11 IS 120

2 – 42/36/32/26/24 watt CFL UNV Side Exit

10 Pack
47506, 47509

UL Class P

Power Factor % (>=)
98
98
95
95

ProLine® CFL Electronic Ballasts

ProLine CFL Electronic Ballasts

Supply Current Frequency

System Watts
76
73
41
40

80680 – C240SI120RH-IP

®

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Line Volts
120
277
120
277

CSA

• Electronic compact fluorescent ballasts for all general fluorescent applications
• Low-profile case

47506 – C242UNVBES-IP
47509 – C242UNVSE-IP

FT40W/4P

# of Lamps
2
2
1
1

T12
Fluorescent Ballasts

# of Lamps Line Volts
System Watts
Nom. Line Current
2
120
54
0.45 A
2
277
54
0.20 A
1
120
29
0.24 A
CFTR26W/GX24q
1
277
29
0.11 A
1
120
51
0.43 A
1
277
51
0.19 A
2
120
27
0.23 A
CFQ26W/G24q
2
277
27
0.10 A
1
120
46
0.38 A
CFTR42W/GX24q
1
277
46
0.17 A
1
120
36
0.31 A
CFTR32W/GX24q
1
277
36
0.13 A
Other compatible lamps: F24T5/HO, CFS21W/GR10q, FT24W/2G11, FC16T9/40W

8.8 in (225.80 mm)
0.8 in (22.35 mm)
0.3 in (7.92 mm)
1.10 lbs
Side
12 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
48 in (1219 mm)
25 in (635 mm)

Specifications by lamp and wattage
Lamp

Lamp

9.5 in (241.30 mm)
1.5 in (38.10 mm)
1.0 in (25.40 mm)

T5
Fluorescent Ballasts

Electronic – Program / Rapid start
Programmed start
Series
10%
104°F (40°C)
75°C (167°F)
Normal
Active
A (20-24 decibels)
Auto restart, Thermally protected, Universal voltage

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

2 – CFQ26W, FT24 or 1 – 24W CFTR32 120-227V ProLine® PS

Supply Current Frequency

ProLine® CFL Electronic Ballasts
2 or 1 – FT40W2G11 PS UNV

®

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• Electronic compact fluorescent ballasts for all general fluorescent applications
• Low-profile case

80683 – C240PUNVHP-B-IP

T8
Fluorescent Ballasts

• Multi-voltage technology means a single ballast handles voltage from 108V to 305V
• Programmed starting for extended lamp life
• End-of-Lamp-Life protection
• Color coded poke-in connectors simplifies wiring

71443 – GEC226-MVPS-BES
71444 – GEC226-MVPS-SE
71445 – GEC226-MVPS-3W

Quick Reference
Guides

gelighting.com

ProLine® CFL Electronic Ballasts

ProLine® CFL Electronic Ballasts

For 40W Biax® CFL Ballasts

For 40W Biax® CFL Ballasts
• Electronic compact fluorescent ballasts for all general fluorescent applications
• Low-profile case

80681 – C240SI277RH-IP

• Electronic compact fluorescent ballasts for all general fluorescent applications
• Low-profile case

80691 – C340SI277RH-IP
ProLine® CFL Electronic Ballasts

2 – FT40W/2G11- IS 277

3 – FT40W/2G11 IS 277

General characteristics

Dimensions

Electrical characteristics
Supply Current Frequency

50 Hz /60 Hz

Order information
10 Pack
80681

Pallet Pack

DIY Pack

General characteristics

Wiring diagram – CFL 1B – see example on page 131
Case dimensions – Ref Drawing C6 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
Red
White
Black

IP Pack

8.3 in (211.07 mm)
2.4 in (60.96 mm)
1.5 in (39.37 mm)
9.5 in (241.30 mm)
8.8 in (225.80 mm)
1.6 in (42.87 mm)
0.3 in (7.92 mm)
2.70 lbs
Side
12 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
33 in (838 mm)
25 in (635 mm)
25 in (635 mm)

Line Volts
277
277

System Watts
67
40

Safety and performance

Wiring diagram – CFL 51 – see example on page 131
Case dimensions – Ref Drawing C6 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
Red
White
Black

Electrical characteristics
50 Hz /60 Hz

Order information
10 Pack
80691

Pallet Pack

DIY Pack

IP Pack

8.3 in (211.07 mm)
2.4 in (60.96 mm)
1.5 in (39.37 mm)
9.5 in (241.30 mm)
8.8 in (225.80 mm)
1.6 in (42.87 mm)
0.3 in (7.92 mm)
2.70 lbs
Side
12 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
33 in (838 mm)
25 in (635 mm)
25 in (635 mm)

Specifications by lamp and wattage
Nom. Line Current
0.27 A
0.17 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.88
1.02

Ballast Efficacy Factor
1.31
2.55

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=)
95
90
CSA

Crest Factor (<=)
1.7
1.7

THD (<=)
20
20

Min. Starting Temp (°F/°C)
50 / 10
50 / 10

Lamp
FT40W/4P

# of Lamps
3
2

Line Volts
277
277

System Watts
98
75

Safety and performance

UL Listed

Nom. Line Current
0.39 A
0.30 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.88
0.99

Ballast Efficacy Factor
0.89
1.32

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=)
95
90
CSA

Crest Factor (<=)
1.7
1.7

THD (<=)
20
20

Min. Starting Temp (°F/°C)
50 / 10
50 / 10

UL Listed

Sign
Ballasts

• Electronic compact fluorescent ballasts for all general fluorescent applications
• Low-profile case

80690 – C340SI120RH-IP

T12
Fluorescent Ballasts

FT40W/4P

# of Lamps
2
1

Electronic – Standard Instant Start
Instant start
Series
10%
105°F (41°C)
70 °C (158 °F)
Normal
Passive
A (20-24 decibels)
End-of-Life Protection (EOL), Thermally protected

Supply Current Frequency

Specifications by lamp and wattage
Lamp

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Electronic – Standard Instant Start
Instant start
Series
10%
105°F (41°C)
70 °C (158 °F)
Normal
Passive
A (20-24 decibels)
End-of-Life Protection (EOL), Thermally protected

T8
Fluorescent Ballasts

ProLine® CFL Electronic Ballasts
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Quick Reference
Guides

gelighting.com

ProLine® CFL Electronic Ballasts
3 – FT40W/2G11 IS 120

General characteristics

Dimensions
Electronic – Standard Instant Start
Instant start
Series
10%
105°F (41°C)
70 °C (158 °F)
Normal
Passive
A (20-24 decibels)
End-of-Life Protection (EOL), Thermally protected

Electrical characteristics
Supply Current Frequency

50 Hz /60 Hz

Order information
10 Pack
80690

Pallet Pack

DIY Pack

IP Pack

8.3 in (211.07 mm)
2.4 in (60.96 mm)
1.5 in (39.37 mm)
9.5 in (241.30 mm)
8.8 in (225.80 mm)
1.6 in (42.87 mm)
0.3 in (7.92 mm)
2.70 lbs
Side
12 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
33 in (838 mm)
25 in (635 mm)
25 in (635 mm)

HID Electronic
Ballasts

Wiring diagram – CFL 51 – see example on page 131
Case dimensions – Ref Drawing C6 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
Red
White
Black

Compact Fluorescent
Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp
FT40W/4P

# of Lamps
3
2

Line Volts
120
120

Safety and performance

Nom. Line Current
0.88 A
0.68 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.88
0.99

Ballast Efficacy Factor
0.89
1.32

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=)
95
90
CSA

Crest Factor (<=)
1.7
1.7

THD (<=)
20
20

Min. Starting Temp (°F/°C)
50 / 10
50 / 10

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

127

HID Electromagnetic
Ballasts

126

System Watts
98
75

ProLine® CFL Electronic Ballasts

CFL Magnetic Ballasts

For 5 – 26W Preheat CFL Lamps

For 5 – 26W Preheat CFL Lamps
• Magnetic compact fluorescent ballast construction for all general fluorescent lighting

87634 – GEM1CF579PH277

2 – CFT/Q13W/GX23 Pre Heat 277 (4214PBES)

General characteristics

Dimensions
Magnetic – Preheat
Preheat
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
87634

Pallet Pack

DIY Pack

IP Pack

2.8125 (71.43 mm)
1.1875 (30.16 mm)
1.6 in (41.14 mm)
2.8 in (71.45 mm)
2.3 in (60.45 mm)
0.1 in (4.77 mm)
0.60 lbs
Side
10 ft
18 AWG
Length (± 1 in)
7 in (178 mm)
9 in (229 mm)

Line Volts
277
277
277
277
277
277

System Watts
11
11
11
10
9
8

Safety and performance

Electrical characteristics

System Ballast Factor
0.90
0.85
1.00
1.00
0.95
0.95

UL Type HL

UL Class P

Order information
10 Pack
87655

Ballast Efficacy Factor
8.18
7.72
9.09
10.00
10.55
11.87

Power Factor % (>=)
25
27
50
22
45
40

Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7

THD (<=)
15
15
15
15
15
15

Min. Starting Temp (°F/°C)
25 / -4
25 / -4
25 / -4
25 / -4
25 / -4
25 / -4

Dimensions

A (20-24 decibels)
Thermally protected

60 Hz

Order information
DIY Pack

Safety and performance

Nom. Line Current
0.12 A
0.12 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.90
0.90
UL Class P

Ballast Efficacy Factor
2.81
2.81

Power Factor % (>=)
95
95

Crest Factor (<=)
1.7
1.7

THD (<=)
30
30

Min. Starting Temp (°F/°C)
25 / -4
25 / -4

UL Listed

• Magnetic compact fluorescent ballast construction for all general fluorescent lighting

87700 – GEM2CF24PH277

IP Pack

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

3.0 in (77.01 mm)
1.25 in (31.75 mm)
1.75 in (44.45 mm)
3.0 in (77.01 mm)
2.75 in (69.85 mm)
0.2 in (5.58 mm)
0.62 lbs
Side
10 ft
18 AWG
Length (± 1 in)
7 in (178 mm)
9 in (229 mm)

Magnetic – Preheat
Preheat
Parallel
5%
105°F (41°C)
90°C (194°F)
Normal
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
87700

Pallet Pack

DIY Pack

IP Pack

Wiring diagram – CFL 8 – see example on page 131
Case dimensions – Ref Drawing 10 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
Black
White

6.5 in (166.62 mm)
2.3 in (60.45 mm)
1.6 in (42.92 mm)
6.5 in (166.62 mm)
6.0 in (152.40 mm)
0.3 in (7.87 mm)
2.93 lbs
Bottom
10 ft
18 AWG
Length (± 1 in)
15 in (381 mm)
15 in (381 mm)
15 in (381 mm)

Specifications by lamp and wattage
Nom. Line Current
0.25 A
0.25 A
UL Class P

System Ballast Factor
0.90
0.90

cUL Listed

Ballast Efficacy Factor
6.00
6.00

Power Factor % (>=)
50
50

Crest Factor (<=)
1.7
1.7

THD (<=)
10
10

Min. Starting Temp (°F/°C)
50 / 10
50 / 10

Lamp
CFQ26W/2P
CFTR26W/2P

# of Lamps
2
2

Line Volts
277
277

System Watts
55
55

Safety and performance

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

Nom. Line Current
0.25 A
0.25 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.90
0.90
UL Class P

Ballast Efficacy Factor
1.63
1.63

Power Factor % (>=)
97
97

Crest Factor (<=)
1.5
1.5

THD (<=)
30
30

Min. Starting Temp (°F/°C)
25 / -4
25 / -4

UL Listed

129

HID Electromagnetic
Ballasts

128

UL Type HL

System Watts
32
32

HID Electronic
Ballasts

Safety and performance

System Watts
15
15

Line Volts
277
277

General characteristics

Wiring diagram – CFL 21 – see example on page 131
Case dimensions – Ref Drawing 2 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Black

Specifications by lamp and wattage
Line Volts
120
120

# of Lamps
2
2

Compact Fluorescent
Ballasts

Magnetic – Preheat
Preheat
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Electrical characteristics

# of Lamps
1
1

Lamp
CFQ13W/2P
CFT13W/2P

2 – CFQ26W/G24d Pre Heat 277 (4226PBES)

General characteristics

Lamp
CFQ13W/2P
CFT13W/2P

IP Pack

CFL Magnetic Ballasts

1 – CFT/Q13W/GX23 Pre Heat 120 (4111H2P)

Pallet Pack

DIY Pack

0.2 in (5.58 mm)
1.60 lbs
Bottom
10 ft
18 AWG
Length (± 1 in)
12 in (305 mm)
12 in (305 mm)
12 in (305 mm)

Sign
Ballasts

ProLine® CFL Electronic Ballasts

10 Pack
87533

Pallet Pack

4.75 in (120.65 mm)
4.375 in (111.12 mm)

UL Listed

• Magnetic compact fluorescent ballast construction for all general fluorescent lighting

87533 – GEM1CF13PH120

Supply Current Frequency

60 Hz

4.75 in (120.65 mm)
2.1 in (55.62 mm)
1.6 in (41.40 mm)

Specifications by lamp and wattage
Nom. Line Current
0.16 A
0.15 A
0.14 A
0.18 A
0.15 A
0.16 A

UL Type 1 Outdoor

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

A (20-24 decibels)
Auto-restart, Thermally protected

Wiring diagram – CFL 9 – see example on page 131
Case dimensions – Ref Drawing 8 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
Black
White

T12
Fluorescent Ballasts

# of Lamps
1
1
1
1
1
1

Magnetic – Preheat
Preheat
Series
5%
105°F (41°C)
90°C (194°F)
Normal

Supply Current Frequency

Specifications by lamp and wattage
Lamp
CFT7W/2P
CFT9W/2P
F8T5
CFT5W/2P
F6T5
F4T5

Dimensions

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

T5
Fluorescent Ballasts

A (20-24 decibels)
Auto-restart, Thermally protected

General characteristics

Wiring diagram – CFL 21 – see example on page 131
Case dimensions – Ref Drawing 01 – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Black

T8
Fluorescent Ballasts

CFL Magnetic Ballasts

1 – CFT579Q9W/G23 Pre Heat 277 (4205F2P)
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

• Magnetic compact fluorescent ballast construction for all general fluorescent lighting

87655 – GEM2CF13PH277

ProLine® CFL Electronic Ballasts

Quick Reference
Guides

gelighting.com

CFL Magnetic Ballasts

Wiring Diagrams
Compact Fluorescent Ballasts

For 36 – 40W CFL Lamps
• Magnetic compact fluorescent ballast construction for all general fluorescent lighting

87623 – GEM2FT36RS120

CFL 20C

CFL 1B

CFL 51

CFL 21

CFL 9

CFL 8

T8
Fluorescent Ballasts

CFL Magnetic Ballasts
2 – FT36W/2G11 RS 120 (4150P)

General characteristics

Dimensions
Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
87623

Pallet Pack

DIY Pack

IP Pack

Wiring diagram – CFL 5 – see example on page 132
Case dimensions – Ref Drawing ST – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Yellow

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)
8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
3.38 lbs
Side
10 ft
18 AWG
Length (± 1 in)
20 in (508 mm)
20 in (508 mm)
20 in (508 mm)

T5
Fluorescent Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

Specifications by lamp and wattage
Lamp
FT36W/4P

# of Lamps
2

Line Volts
120

System Watts
78

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
0.96
UL Class P

Ballast Efficacy Factor
1.23

Power Factor % (>=)
93

Crest Factor (<=)
1.7

THD (<=)
20

Min. Starting Temp (°F/°C)
50 / 10

UL Listed

T12
Fluorescent Ballasts

Safety and performance

Nom. Line Current
0.70 A

Sign
Ballasts

• Magnetic compact fluorescent ballast construction for all general fluorescent lighting

87625 – GEM2FT40RS120

Quick Reference
Guides

gelighting.com

CFL Magnetic Ballasts
2 – FT40W/2G11RS RS 120 (4152P)

General characteristics

Dimensions
Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal
A (20-24 decibels)
Auto-restart, Thermally protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
10 Pack
87625

Pallet Pack

DIY Pack

IP Pack

Wiring diagram – CFL 5 – see example on page 132
Case dimensions – Ref Drawing ST – see page 133
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Yellow

9.5 in (241.30 mm)
2.3 in (60.45 mm)
1.5 in (39.37 mm)
8.8 in (225.80 mm)
1.6 in (42.92 mm)
0.3 in (7.92 mm)
3.38 lbs
Side
10 ft
18 AWG
Length (± 1 in)
20 in (508 mm)
20 in (508 mm)
20 in (508 mm)

Compact Fluorescent
Ballasts

Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info

HID Electronic
Ballasts

Specifications by lamp and wattage
Lamp
FT40W/4P

# of Lamps
2

Line Volts
120

Safety and performance

Nom. Line Current
0.68 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor
1.00
UL Class P

Ballast Efficacy Factor
1.23

Power Factor % (>=)
98

Crest Factor (<=)
1.7

THD (<=)
20

Min. Starting Temp (°F/°C)
50 / 10

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

131

HID Electromagnetic
Ballasts

130

System Watts
81

Case Dimensions
Compact Fluorescent Ballasts

CFL 5

-B

8

01

10

T8
Fluorescent Ballasts

Wiring Diagrams
Compact Fluorescent Ballasts

Quick Reference
Guides

gelighting.com

T5
Fluorescent Ballasts
T12
Fluorescent Ballasts

2
Sign
Ballasts

CFL 1-2
13

Compact Fluorescent
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

ST

133

HID Electromagnetic
Ballasts

132

HID Electronic
Ballasts

C6

Electronic HID
For 20 – 150W Pulse Start HID Lamps
Electronic HID

T8
Fluorescent Ballasts

• Light weight, low-profile housing
• Superior low-frequency square-wave-frequency design maximizes performance and life of
ceramic metal halide lamps
• Ultra-slim can size for fixture design flexibility

87490 – GEMH20-MLF-120
1 – 20W M156 120V Electronic HID

General characteristics

®

GE’s line of UltraCool UltraMax eHID ballasts can provide up to 70% energy savings and
four times the life of standard halogen. End users can meet strict watts per square foot
requirements while achieving significant wattage savings and color control with ceramic
metal halide lamps and GE eHID ballasts.

133 Hz
60 Hz/ 50 Hz/ Supply Current Frequency (MIN) / 50 Hz

Order information
Type
Case

No. Items Per Sales Unit
1

No. Items Per Standard Package
12

Specifications by lamp and line voltage
Lamp
M156
20W Ceramic
Metal Halide

Specifications by line voltage
120
22.50
0.36 A
1
0.89
4,000V
96V
56
1.40
79
0 / -18
3

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

RoHS Compliant

ANSI – C62.41

UL 1029 Listed

FCC-CLASS A Non-Consumer

Electronic HID
1 – 39W M130 120V Electronic HID

General characteristics

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Ambient Temperature (MAX)
Case Temperature (MAX)
Sound Rating
Additional Info

Electronic – Low Frequency
M130
120
10%

Wiring diagram WD-eHID MLF/MSF – see example on page 140
Case dimensions – Ref Drawing MSF – see page 141
Length (L)
3.7 in (94.99 mm)
Width (W)
2.9 in (75.69 mm)
Height (H)
1.2 in (30.73 mm)
Frame Size (H x L)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
3.3 in (86.10 mm)
Mount Width (X or F)
2.5 in (63.75 mm)
Mount Slots (MS)
0.1 in (4.31 mm)
Weight
0.38 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
8 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Black
Brown
White
Red

131°F (55°C)
90 °C (194 °F)
A (20-24 decibels)
End-of-Life Protection (EOL), Thermally protected

Electrical characteristics
130 Hz

Lamp Watts

Voltage
120 = 120 volt
277 = 277 volt
347 = 347 volt
480 = 480 volt
MV = 120-277 volts
Pack Type
No extension
= Standard
Distributor Pack
B=Bulk pack

Specifications by line voltage

Safety and performance
See page 195 for warranty information.

120
43.00
0.37 A
1.00
0.91

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

96V
99
1.40
6.80
0 / -18
3

RoHS Compliant

See page 195 for warranty information.

UL Type 1 Outdoor

ANSI – C62.41

Suitable for recessed use

UL 1029 Listed

cUL Listed

UL Listed

135

HID Electromagnetic
Ballasts

134

Connector
F = Side leads w/ feet
N = Side leads no feet
J = Bottom leads
w/ studs
JN = Bottom leads
no studs

No. Items Per Standard Package
10

Specifications by lamp and line voltage
Lamp
M130
39W Ceramic
Metal Halide

G E M H 1 0 0 M S F - 1 2 0
Housing
MA=Metal
Housing
ML=Mini Slim
MS=Mini Square
SL=Slim Line
E=PCB board

No. Items Per Sales Unit
1

HID Electronic
Ballasts

Order information
Type
Case

GE Ballast
GEMH = Electronic MH

UL Listed

87501 – GEMH39-MSF-120

Lamp Operating Frequency

GE Ballast HID Electronic nomenclature

cUL Listed

Compact Fluorescent
Ballasts

GE high-wattage eHID ballasts will operate 250, 300, 320,350 or 400 watt pulse start or
ceramic metal halide lamps with one ballast. The eHID Ballast with a PulseArc lamp will produce
70% more lumens per watt than the obsolete probe start magnetic core and coil system.
Variable dimming to 50% power reduction is an option with GE eHID high wattage ballast.

Electrical characteristics
Lamp Operating Frequency
Supply Current Frequency

Sign
Ballasts

GE’s UltraMax® eHID ballasts operate only pulse start and ceramic metal halide lamps.
GE UltraMax® eHID ballasts operate lamps at a low frequency square wave to maximize
lamp performance. Extensive analysis of all brands of lamps suggests that the most
compatible driving waveform for an electronic HID electronic ballast is a low-frequency
squared wave (L.F.S.W.) with higher order harmonic content. L.F.S.W. has been established as
a dependable method of ballasting low-wattage HID lamps with significant industry support.
Analysis of lamp data has shown that there are limited operating bands between 1 kHz to
200 kHz in which electronic ballast could operate a lamp wattage family without causing
unacceptable arc instability due to acoustic resonance. GE’s UltraMax® eHID constantly
measures and adjusts the wattage, optimizing the ceramic metal halide lamp performance.

131°F (55°C)
85°C (185°F)
A (20-24 decibels)
End-of-Life Protection (EOL), Inherent thermal protection

Wiring diagram WD-eHID MLF/MSF – see example on page 140
Case dimensions – Ref Drawing MLF – see page 141
Length (L)
3.7 in (94.99 mm)
Width (W)
1.5 in (39.87 mm)
Height (H)
1.0 in (25.40 mm)
Frame Size (H x L)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
3.3 in (85.34 mm)
Mount Width (X or F)
1.1 in (30.22 mm)
Mount Slots (MS)
0.1 in (4.31 mm)
Weight
0.38 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
8 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Black
Brown
White
Red

T12
Fluorescent Ballasts

GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID,
like electronic fluorescent systems that preceded it, significantly improve the performance
of HID lighting. Electronic UltraMax® eHID Ballasts use solid-state components to start and
operate HID lamps. Electronic eHID ballasts use IC chips to control and give feedback for
optimal performance of the lighting system. GE eHID ballasts improve the efficiency, maintain
higher lumens, enhance lamp life and color control, and operate more quietly than the
magnetic core and coil ballast that they replace.

Electronic – Low Frequency
M156
120
10%
Electronic

T5
Fluorescent Ballasts

Understanding Electronic
UltraMax® HID Ballasts

™

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Ambient Temperature (MAX)
Case Temperature (MAX)
Sound Rating
Additional Info

Quick Reference
Guides

gelighting.com

Electronic HID

For 20 – 150W Pulse Start HID Lamps

For 20 – 150W Pulse Start HID Lamps

87516 – GEMH50-MSF-120

87546 – GEMH70-SLJ-MV

Electronic HID

Electronic HID
1 – 70W, M98, M/C143, 120V. Electronic HID

1 – 50W, M110, M/C148, 120V. Electronic HID

General characteristics
Electronic – Low Frequency
M148, M110, C148
120
10%
Electronic

Electrical characteristics
130 Hz
60 Hz/50 Hz

Order information
No. Items Per Sales Unit
1

Length (± 1 in)
10 in (254 mm)
10 in (254 mm)
10 in (254 mm)
10 in (254 mm)

No. Items Per Standard Package
10

120
58
0.48 A
1

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

131°F (55°C)
90°C (194°F)
A (20-24 decibels)
End of Life Protection (EOL), Thermally protected

Electrical characteristics
Lamp Operating Frequency

130 Hz

Order information
No. Items Per Sales Unit
1

96V
99
1.4
6.9
0 / -18
130

Lamp
M98, M143, M139,
C143, C139
70W Ceramic
Metal Halide

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

120
58
0.48 A
1
0.86

70W Quartz
Metal Halide

96V
99
1.4
6.9
0 / -18
130

Pulse Arc

RoHS Compliant

UL Type 1 Outdoor

ANSI – C62.41

UL 1029 Listed

FCC-CLASS A Non-Consumer

cUL Listed

277
77
0.30 A
1
0.91

96V
99
1.4
4.9
0 / -18
3

96V
97
1.4
7.7
0 / -18
3

RoHS Compliant

Electronic HID

1 – 70W, M98, M/C143, 120V Electronic HID

Dimensions

General characteristics

Length (± 1 in)
10 in (254 mm)
10 in (254 mm)
10 in (254 mm)
10 in (254 mm)

cUL Listed

131°F (55°C)
90°C (194°F)
A (20-24 decibels)
End of Life Protection (EOL), Thermally protected

130 Hz

Length (± 1 in)
10 in (254 mm)
10 in (254 mm)
10 in (254 mm)
10 in (254 mm)

No. Items Per Standard Package
10

Electronic – Low Frequency
M90, M140, C140
120/277
10%

131°F (55°C)
90°C (194°F)
A (20-24 decibels)
End of Life Protection (EOL), Thermally protected

Electrical characteristics
Lamp Operating Frequency

130 Hz

Order information
Type
Case

No. Items Per Sales Unit
1

No. Items Per Standard Package
10

Specifications by lamp and line voltage
Lamp
M90, M140
100W Ceramic
Metal Halide

Specifications by line voltage
120
77
0.68 A
1.00
0.91

RoHS Compliant

UL Type 1 Outdoor

ANSI – C62.41

UL 1029 Listed

FCC-CLASS A Non-Consumer

cUL Listed

UL Listed

See page 195 for warranty information.

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

120
110
0.93 A
1
0.91

277
107
0.41 A
1
0.93

96V
99
1.4
4.7
0 / -18
3

96V
98
1.4
7.8
0 / -18
3

RoHS Compliant

See page 195 for warranty information.

UL Type 1 Outdoor

Lamp
C140

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

ANSI – C62.41

UL 1029 Listed

120
110
0.93 A
1

277
107
0.41 A
1

96V
99
1.4
4.7
0 / -18
3

96V
98
1.4
7.8
0 / -18
3

cUL Listed

137

HID Electromagnetic
Ballasts

100W Quartz
Metal Halide

99
1.4
8.3
0 / -18
3

Housing meets UL94V0 flame retardant

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Ambient Temperature (MAX)
Case Temperature (MAX)
Sound Rating
Additional Info

Specifications by lamp and line voltage

Safety and performance

Wiring diagram WD - eHID SLJ – see example on page 140
Case dimensions – Ref Drawing SLJ – see page 141
Length (L)
7.2 in (184.91 mm)
Width (W)
2.5 in (65.53 mm)
Height (H)
2.2 in (55.88 mm)
Frame Size (H x L)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
0.4 in (10.92 mm)
Mount Width (X or F)
Mount Slots (MS)
Weight
0.38 lbs
Exit Type
Bottom Leads with Studs
Remote Mounting Distance to Lamp
8 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Qty
Exit
Black
1
Left
Brown
1
Right
White
1
Left
Red
1
Right

FCC-CLASS A Non-Consumer

HID Electronic
Ballasts

Wiring diagram WD-eHID MLF/MSF – see example on page 140
Case dimensions – Ref Drawing MSF – see page 141
Length (L)
3.7 in (94.99 mm)
Width (W)
2.9 in (75.69 mm)
Height (H)
1.2 in (30.73 mm)
Frame Size (H x L)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
3.3 in (86.10 mm)
Mount Width (X or F)
2.5 in (63.75 mm)
Mount Slots (MS)
0.1 in (4.31 mm)
Weight
0.38 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
8 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Qty
Exit
Black
1
Left
Brown
1
Right
White
1
Left
Red
1
Right

Order information

136

UL 1029 Listed

Compact Fluorescent
Ballasts

Electronic – Low Frequency
M98, M143, M139, C143, C139
120
10%

Electrical characteristics

70W Quartz
Metal Halide

ANSI – C62.41

1 – 100W, M90, M/C140, 120V-277V Electronic HID

General characteristics

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

UL Type 1 Outdoor

Sign
Ballasts

Electronic HID

Lamp
M98, M143, M139 ,
C143, C139
70W Ceramic
Metal Halide

Length (± 1 in)
10 in (254 mm)
10 in (254 mm)
10 in (254 mm)
10 in (254 mm)

UL Listed

87561 – GEMH100-SLJ-MV

No. Items Per Sales Unit
1

0.38 lbs
Bottom Leads with Studs
8 ft
18 AWG
Qty
Exit
1
Left
1
Right
1
Left
1
Right

No. Items Per Standard Package
10

120
77
0.66 A
1
0.91

87531 – GEMH70-MSF-120

Type
Case

0.4 in (10.92 mm)

Specifications by Line Voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

Lamp Operating Frequency

7.2 in (184.91 mm)
2.5 in (65.53 mm)
2.2 in (55.88 mm)

Specifications by lamp and line voltage
Lamp
M110
50W Quartz
Metal Halide

Housing meets UL94V0 flame retardant

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Ambient Temperature (MAX)
Case Temperature (MAX)
Sound Rating
Additional Info

Wiring diagram WD-eHID SLJ – see example on page 140
Case dimensions – Ref Drawing SLJ – see page 141
Length (L)
Width (W)
Height (H)
Frame Size (H x L)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Brown
White
Red

T12
Fluorescent Ballasts

Specifications by line voltage

Electronic – Low Frequency
M98, M143, C143, M139, C139
120/277
10%

Type
Case

Specifications by lamp and line voltage
Lamp
M148
C148

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Ambient Temperature (MAX)
Case Temperature (MAX)
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Wiring diagram WD-eHID MLF/MSF – see example on page 140
Case dimensions – Ref Drawing MSF – see page 141
Length (L)
3.7 in (94.99 mm)
Width (W)
2.9 in (75.69 mm)
Height (H)
1.2 in (30.73 mm)
Frame Size (H x L)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
3.3 in (86.10 mm)
Mount Width (X or F)
2.5 in (63.75 mm)
Mount Slots (MS)
0.1 in (4.31 mm)
Weight
0.62 lbs
Exit Type
Side
Remote Mounting Distance to Lamp
8 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Qty
Exit
Black
1
Left
Brown
1
Right
White
1
Left
Red
1
Right

131°F (55°C)
90°C (194°F)
A (20-24 decibels)
End of Life Protection (EOL), Thermally protected

Lamp Operating Frequency
Supply Current Frequency

Type
Case

General characteristics

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Ambient Temperature (MAX)
Case Temperature (MAX)
Sound Rating
Additional Info

T8
Fluorescent Ballasts

Electronic HID

Quick Reference
Guides

gelighting.com

Electronic HID

For 20 – 150W Pulse Start HID Lamps

For 250 – 400W Pulse Start HID Lamps

87576 – GEMH150-SLJ-MV

29377 – GE-MH-250-400-MA

Electronic HID

Electronic HID

1 – 150W, M102, M/C142, 120V-277V Electronic HID

1 – 250 to 400W, UltraMax® HID, Electronic, 208-277, 50-60 Hz

General characteristics

Dimensions
Electronic – Low Frequency
M142, M102, C142
120/277
10%

131°F (55°C)
85°C (185°F)
A (20-24 decibels)
End of Life Protection (EOL), Thermally protected

Electrical characteristics
Lamp Operating Frequency

130 Hz

Order information
Type
Case

No. Items Per Sales Unit
1

General characteristics

Wiring diagram WD-eHID SLJ – see example on page 140
Case dimensions – Ref Drawing SLJ – see page 141
Length (L)
Width (W)
Height (H)
Frame Size (H x L)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Brown
White
Red

7.2 in (184.91 mm)
2.5 in (65.53 mm)
2.2 in (55.88 mm)

0.4 in (10.92 mm)
0.38 lbs
Bottom Leads with Studs
8 ft
18 AWG
Qty
Exit
1
Left
1
Right
1
Left
1
Right

Length (± 1 in)
10 in (254 mm)
10 in (254 mm)
10 in (254 mm)
10 in (254 mm)

No. Items Per Standard Package
10

Safety and performance

120
167
1.44 A
1
0.90

277
164
0.62 A
1
0.91

96V
99
1.4
4.2
0 / -18
3

96V
99
1.4
10.6
0 / -18
3

RoHS Compliant

130°F (54°C)
A (20-24 decibels)
Thermally protected

Electrical characteristics
Supply Current Frequency

50 Hz/ 60 Hz

Order information
No. Items Per Sales Unit
1

Length (± 1 in)
9 in (229 mm)
10 in (254 mm)
9 in (229 mm)
9 in (229 mm)

No. Items Per Standard Package
1

UL Type 1 Outdoor

Lamp
C142

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

ANSI – C62.41

UL 1029 Listed

120
167
1.44 A
1

277
164
0.62 A
1

96V
99
1.4
4.2
0 / -18
3

96V
99
1.4
10.6
0 / -18
3

FCC-CLASS A Non-Consumer

Lamp
M155, M135
400W Quartz
Metal Halide

Lamp
208
240
277
M154, M132
System Wattage (W)
431
431
428
320W Quartz
Nominal Current
2.23 A
1.92 A
1.65 A
Metal Halide
Ballast Factor
1
1
1
Ballast Efficiency Factor
0.93
0.93
0.93
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
99
99
99
Crest Factor (<)
THD % (<)
15
15
15
Min. Starting Temp (°F/°C)
-20 / -29
-20 / -29
-20 / -29
Fuse Rating
UL Bench Top Rise
*Specifications by lamp and line voltage limited to two charts, please see gelighting.com for additional lamps.

cUL Listed

Specifications by line voltage

Safety and performance

UL Type 1 Outdoor

UL Type HL

UL Class P

T12
Fluorescent Ballasts

150W Ceramic
Metal Halide

Wiring diagram eHID – see example on page 140
Case dimensions – Ref Drawing eHID - Bracket – see page 141
Length (L)
14.9 in (378.66 mm)
Width (W)
14.9 in (378.66 mm)
Height (H)
9.3 in (237.79 mm)
Frame Size (H x L)
Mounting dimensions
Bracket Length (BL)
6.5 in (165.10 mm)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
10.20 lbs
Exit Type
Bottom
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Qty
Exit
Black and Green
1
Bottom
Brown and Red
1
Bottom
White
1
Bottom
Yellow
2
Bottom

Specifications by lamp and line voltage

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Electronic – Dimming
M155, M153, M138, M135, M132, M131, M154
208/240/277
10%
Electronic

Type
Standard Pack

Specifications by lamp and line voltage
Lamp
M102, M142
150W Quartz
Metal Halide,

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Ambient Temperature (MAX)
Case Temperature (MAX)
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Ambient Temperature (MAX)
Case Temperature (MAX)
Sound Rating
Additional Info

• High efficiency electronic ballast provides 48% less ballast losses compared to electromagnetic
CWA ballasts
• Improves lumen maintenance by 10 points on pulse start lamps
• Multi-voltage technology handles voltage from 208 to 277V

T8
Fluorescent Ballasts

Electronic HID

Quick Reference
Guides

gelighting.com

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

FCC-CLASS A Non-Consumer

cUL Listed

208
346
1.79 A
1
0.92

240
346
1.54 A
1
0.92

277
343
1.34 A
1
0.93

99

99

99

15
-20 / -29

15
-20 / -29

15
-20 / -29

UL Listed

Sign
Ballasts

89646 – GEMH250-400M-V50
Electronic HID
1 – 250 to 400W, UltraMax® HID, Dimming, 208-277, 50-60Hz

General characteristics

Dimensions
Electronic – Dimming
M155, M153, M138, M135, M132, M131
208/240/277
10%
Electronic

130°F (54°C)
A (20-24 decibels)
Thermally protected

Electrical characteristics
Supply Current Frequency

50 Hz/ 60 Hz

Order information
Type
Standard Pack

No. Items Per Sales Unit
1

14.9 in (378.66 mm)
14.9 in (378.66 mm)
9.3 in (237.79 mm)

6.5 in (165.10 mm)
10.20 lbs
Bottom
Qty
1
1
1
2

Exit
Bottom
Bottom
Bottom
Bottom

Length (± 1 in)
9 in (229 mm)
10 in (254 mm)
9 in (229 mm)
9 in (229 mm)

HID Electronic
Ballasts

Wiring diagram eHID– see example on page 140
Case dimensions – Ref Drawing eHID-DIM – see page 141
Length (L)
Width (W)
Height (H)
Frame Size (H x L)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black and Green
Brown and Red
White
Yellow

Compact Fluorescent
Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Ambient Temperature (MAX)
Case Temperature (MAX)
Sound Rating
Additional Info

No. Items Per Standard Package
1

Specifications by lamp & line voltage
Lamp
M155, M135
400W Quartz
Metal Halide

Specifications by line voltage

Safety and performance
138

See page 195 for warranty information.

See page 195 for warranty information.

UL Type 1 Outdoor
UL 1029 Listed

UL Type HL

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Crest Factor (<)
THD % (<)
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Housing meets UL94V0 flame retardant

FCC-CLASS A Non-Consumer

cUL Listed

ANSI – C62.41

RoHS Compliant

208
346
1.79 A
1
0.92

240
346
1.54 A
1
0.92

277
343
1.34 A
1
0.93

99

99

99

15
-20 / -29

15
-20 / -29

15
-20 / -29

UL Listed

139

HID Electromagnetic
Ballasts

Lamp
208
240
277
M154, M132
System Wattage (W)
431
431
428
320W Quartz
Nominal Current
2.23 A
1.92 A
1.65 A
Metal Halide
Ballast Factor
1
1
1
Ballast Efficiency Factor
0.93
0.93
0.93
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
99
99
99
Crest Factor (<)
THD % (<)
15
15
15
Min. Starting Temp (°F/°C)
-20 / -29
-20 / -29
-20 / -29
Fuse Rating
UL Bench Top Rise
*Specifications by lamp and line voltage limited to two charts, please see gelighting.com for additional lamps.

Wiring Diagrams
HID Electronic
WD-eHID MLF/MSF

WD-eHID-SLJ

MLF

MSF

SLJ

eHID-Bracket

T8
Fluorescent Ballasts

MLF
MSF

Case Dimensions
HID Electronic

Quick Reference
Guides

gelighting.com

SLJ

T5
Fluorescent Ballasts

eHID

T12
Fluorescent Ballasts
Sign
Ballasts
Compact Fluorescent
Ballasts

eHID-DIM

HID Electronic
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

141

HID Electromagnetic
Ballasts

140

Warm-Up Time
5-7 minutes
3-4 minutes
2 minutes
7-10 minutes

Restrike Time
3-6 minutes
10-20 minutes
3-4 minutes
1/2-1 minute

GE Oil-filled Capacitors are packaged in metal cases (up to
520V ratings). All GE capacitors are designed for 60,000 hours of
continuous life.

UL Bench Top
Letter Code
A
B
C
D
E
F

Temperature Range for
Class H (180C) Ballast
Less than 75C
75C < 80C
80C < 85C
85C < 90C
90C < 95C
95C < 100C

Dry Capacitors do not contain oil and are manufactured with
plastic casing. Dry casings are rated up 100°C maximum.
Dry capacitors are designed and rated for AC voltages below
400V at 50 or 60Hz.

GE HID Ballast Types

GE HID ballast 150 watts or less have High Reactance Autotransformer circuits and high
power factor (HX-HPF). GE HID ballast greater that 150 watts have Constant Wattage
Autotransformer circuits and are high power factor (HPF).

Potted Core and Coil Ballast
GE potted core and coil ballasts are designed for applications
requiring quieter or cooler operation than provided by standard coil
and coil ballast. The potting material is sand-filled polyester which
provides excellent sound-deadening and heat-transfer qualities.

See page 195 for warranty information.

G E M 1 0 0 0 M L T A C 5 D - 5
GE Ballast
M = EM Ballast
GEH = Mercury
GEM = Metal
Halide
GEP = Pulse
Start Metal
Halide
GES = HPS

Lamp Watts:
1000W
Voltage:
MLT = Quad
ML5 = Multi 5
T = Trivolt
48T = 480/120 tap
277 = 277V
230 = 230V

Circuit Type:
R = Reactor
A = CWA
I = CWI
O = Iso Reg
L = High
Reactance/lag
M = Mag Lag
Type:
C = Core & Coil Cu
A = Core & Coil
Aluminum
F = F Can
W = Weatherproof
E = Encased/Potted
I = Indoor Encased

Frame Size:
E=E&I
3 = 3x4
4 = 4-3/4
5 = 5-3/4
X = non C & C
Capacitor:
D = Dry Film
O = Oil Film
Pack Type:
-5 = Dist. Kit
-55 = Dist. Kit
& Lamp
-1 = C & C
-1B = C & C
w/welded
bracket
-60 = C & C
no capacitor
-61 = C & C w/
welded bracket,
no cap

143

HID Electromagnetic
Ballasts

See page 195 for warranty information.

Standard ignitors are supplied with metal halide ballast 150 watts
or less, pulse start metal halide and high-pressure sodium ballast.
There are several different ignitors that meet the needs of many GE
lamp and ballast combinations. The appropriate ignitor is listed in the
catalog under the ballast specifications.

GE Ballast HID Electromagnetic nomenclature

HID Electronic
Ballasts

CWA ballast is the most common circuit for core and coil ballast. CWA circuits provide for
stable light regulation. The CWA circuit consists of a high reactance autotransformer with a
capacitor in series with the lamp resulting with high power factor ballast. In most CWA ballast
circuits a 10% drop in line voltage will only reduce the light output and wattage by 5%. The
CWA circuit ballast requires an igniter for QMH pulse start, ceramic metal halide and HPS
lamps. Igniters are also required for QMH lamps 150 watts or less.

Ignitors
Ignitors are also sold in individual cartons for replacement needs.
Ignitors supply a high voltage pulse to ionize the gas creating the
glow discharge. Once the lamp is started the ignitor stops providing
the pulse. Ignitors are designed to last thousand of hours; however, if
the lamp fails or the socket is empty, the ignitor will continue to pulse.
The lamps should be replaced or the fixture turned off to prevent
premature failure of the ignitor.

Compact Fluorescent
Ballasts

CORE AND COIL
The most common HID ballasts are the core and coil and is used in 90% of the fixture
applications. Core and coil ballasts consist of one, two or three copper (or aluminum) coils on a
core of electrical-grade steel laminations. HID ballasts are classified by the kind of circuit they
use: Reactor (R), High Reactance autotransformer (HX), Constant Wattage Autotransformer
(CWA), Regulated lag (Reg Lag) or Electronic. HID ballast are also classified as high power factor
(HPF) or normal power factor (NPF).

142

Power factor capacitors are used to reduce the negative effects that
inductive devices (HID ballast) have on power factor ratings. GE sells
a complete line of capacitors that must be properly matched to the
lamp and HID ballast. GE capacitors have bleed-in resistors and use
biodegradable, nontoxic (no PCBs) dielectric fluid.

UL Bench Top Temperature Code
To help with UL inspection, the UL Bench top code is listed on the GE
label on the core and coil ballast as 1029X. X is the temperature code
and represented by the following temperature classifications: A, B, C,
D, E and F.

Sign
Ballasts

Light Source
Mercury
Metal Halide (Probe Start)
Metal Halide (Pulse Start)
High Pressure Sodium

Capacitors
Most GE capacitors and ignitors are sold in ballast kits that come
pre-wired and reduce labor cost. Capacitors and ignitors are also
sold separately.

Date Codes
GE HID core and coil ballast manufacturing date codes are located
on the top end of the core. They are printed in white and indicate year,
month manufactured, and order the ballast was manufactured in the
month. A code of 070100001 would indicate manufacture date of
07 (year 2007), 01 (month of January), and 00001 would be the
manufacturing sequence.

T12
Fluorescent Ballasts

HID lamps take several minutes to warm-up and reach full light output. If power is interrupted
between the lamp and the ballast, the arc will extinguish and lamp will go out. The lamp must
cool down and reduce the vapor pressure before it will re-start. Typical warm-up and restrike
times are as follows:

Ignitors and capacitors, where required, are included with the quad
and 5-tap ballast kits.

Ballast Date and Temperature Codes

T5
Fluorescent Ballasts

GE offers High Intensity Discharge (HID) ballasts for mercury, probe start metal halide, pulse
start metal halide and high pressure sodium lamps. Standard metal halide lamps or probe
start metal halide over 150 watts, like fluorescent, are electric discharge lamps and require an
open circuit voltage of nearly two times the operating voltage to the initiate the arc between
the two electrodes in the arc tube. High pressure sodium, pulse start metal halide and probe
start metal halide lamps 150 watts or less require an ignitor to initiate the high voltage to
start the lamps. The ballasts provide the starting voltage with the igniter, where required, and
provides stability for the lamp. HID lamps have negative impedance characteristics and would
draw current until destruction unless a ballast was in place to regulate the current.

Also available for metal halide and high pressure sodium applications
is the 5-tap ballast-lamp replacement kit listed as -55. This easy-tocarry, convenient, all-in-one kit, ensures ballast-lamp compatibility by
including the lamp as well.

F-Can Ballast
GE F-Can ballast is recommended for indoor applications and
where ballast noise must be minimized. F-Can ballast are encased
in fluorescent ballast-type cans and potted with asphalt insulating
materials to minimize noise.

T8
Fluorescent Ballasts

Understanding Electromagnetic
HID Ballasts

Distributor Ballast Kits
GE stocks a comprehensive inventory of quad and 5-tap HID voltage
ballast kits. The kits contain the appropriate core and coil, capacitor,
ignitor (where required), mounting bracket, mounting hardware and
instructions to allow the stocking distributor to meet the needs of
their customer while minimizing their investment in component parts.
The quad ballast kit has color-coded leads to identify voltages and
operates at 120/208/240/277. The 5-tap HID ballast kits also include
480-volt applications and are listed as ML5, though GE also offers
single-voltage kits for 480-volt with 120-volt taps for stand-by lighting.

Quick Reference
Guides

gelighting.com

Metal Halide

Metal Halide

For 20 – 175W Metal Halide HID Lamps

For 20 – 175W Metal Halide HID Lamps

Metal Halide
1 – 50W MH M110 or M148 Quad (120/208/240/277V)

General characteristics

Dimensions
Magnetic – Core and Coil
M110 or M148
120/208/240/277
5%
HX-HPF
180C
Dry film
6 Mfd
280
100°C (212°F)
MH350-1A

No. Items Per Standard Package
6

cUL Listed

208
61
0.30 A
1
0.82
0.67 A
0.34 A
264V
166V
90
-22 / -30
3
C

240
61
0.30 A
1
0.82
0.58 A
0.30 A
264V
192V
90
-22 / -30
2
C

Lamp
M98
70W Ceramic
Metal Halide

277
61
0.20 A
1
0.82
0.50 A
0.26 A
264V
222V
90
-22 / -30
2
C

70W Quartz
Metal Halide

Dimensions

UL Listed

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

86675 – GEM100MLTLC3D-5
Metal Halide
1 – 100W MH M90 or M140 Quad (120/208/240/277V)

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
M92, M90, M140
120/208/240/277
5%
HX-HPF
180C
Dry film
12 Mfd
280
100°C (212°F)

Supply Current Frequency

Wiring diagram HID W-(H)-86675-86718 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
3.0
Weight
5.00 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

60 Hz

Order information
Type
Distributor Kit

240
88
0.40 A
1
0.80
0.75 A
0.49 A
257V
192V
90
-22 / -30
3
A

277
88
0.40 A
1
0.80
0.66 A
0.44 A
257V
222V
90
-22 / -30
2
A

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=) %
Min. Starting Temp
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

See page 195 for warranty information.

120
119
1.10 A
1

208
119
0.60 A
1

240
119
0.50 A
1

277
119
0.50 A
1

2.27 A
1.26 A
274V
96V
90
-22 / -30
5
D

1.30 A
0.69 A
274V
166V
90
-22 / -30
4
D

1.13 A
0.60 A
274V
192V
90
-22 / -30
3
D

0.98 A
0.53 A
274V
222V
90
-22 / -30
3
D

cUL Listed

See page 195 for warranty information.

Lamp
M90, M140
100W
Ceramic
Metal Halide

Specifications by line voltage

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
100W
Max Input Current
Quartz
Starting Current
Metal Halide Open Circuit Voltage
Drop Out Voltage
Power factor (>=) %
Min. starting temperature
Fuse rating
UL bench top rise

120
119
1.10 A
1
0.84
2.27 A
1.26 A
274V
96V
-22 / -30
5
D

208
119
0.60 A
1
0.84
1.30 A
0.69 A
274V
166V
90
-22 / -30
4
D

240
119
0.50 A
1
0.84
1.13 A
0.60 A
274V
192V
90
-22 / -30
3
D

277
119
0.50 A
1
0.84
0.98 A
0.53 A
274V
222V
90
-22 / -30
3
D

UL Listed

145

HID Electromagnetic
Ballasts

cUL Listed

208
88
0.50 A
1
0.80
0.88 A
0.59 A
257V
166V
90
-22 / -30
3
A

No. Items Per Standard Package
6

Specifications by lamp and line voltage
Lamp
M92

Specifications by line voltage
120
88
0.90 A
1
0.80
1.51 A
0.96 A
257V
96V
90
-22 / -30
4
A

No. Items Per Sales Unit
1

HID Electronic
Ballasts

No. Items Per Standard Package
6

Specifications by lamp and line voltage

144

cUL Listed

Electrical characteristics
60 Hz

No. Items Per Sales Unit
1

Safety and performance

480
89
0.20 A
1
0.79
0.44 A
0.16 A
253V
384V
90
-22 / -30
1
C

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=) %
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

General characteristics

Wiring diagram HID W-(H)-86824-86847 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
3.0
Weight
5.00 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Order information

70W Quartz
Metal Halide

Specifications by line voltage

Compact Fluorescent
Ballasts

Magnetic – Core and Coil
M98 or M143
120/208/240/277
5%
HX-HPF
180C
Dry film
8 Mfd
280
100°C (212°F)
MH350-1A

Electrical characteristics

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Standard Package
6

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

General characteristics

Lamp
M98, M143
70W Ceramic
Metal Halide

No. Items Per Sales Unit
1

Safety and performance

UL Listed

1 – 70W MH M98 or M143 Quad (120/208/240/277V)

Type
Distributor Kit

0.25 in (6.35 mm)
2.0
2.0
5.00 lbs
Side
2.7 in (68.58 mm)
2.813 in x 3.939 in

T12
Fluorescent Ballasts

120
61
0.60 A
1
0.82
1.16 A
0.61 A
264V
96V
90
-22 / -30
3
C

Metal Halide

Supply Current Frequency

4.6 in (116.84 mm)

Specifications by lamp and line voltage

86847 – GEM70MLTLC3D-5

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

5.25 in (133.35 mm)
1.25 in (31.75 mm)

60 Hz

Type
Distributor Kit

Specifications by line voltage

Safety and performance

Wiring diagram HID H6 – see example on page 180
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
Width (W)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
A
B
Weight
Exit Type
Nominal Length
Frame Size (H x L)

Order information
No. Items Per Sales Unit
1

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Magnetic – Core and Coil
M98
480
5%
HX-HPF
180C
Dry film
8 Mfd
280
100°C (212°F)

Supply Current Frequency

Specifications by lamp and line voltage
Lamp
M110, M148
50W Quartz
Metal Halide

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics
60 Hz

Order information
Type
Distributor Kit

1 – 70W MH M98 or M143 480

General characteristics

Wiring diagram HID W-(H)-86824-86847 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
1.0
B
2.0
Weight
3.40 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Electrical characteristics
Supply Current Frequency

Metal Halide

T5
Fluorescent Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86839 – GEM7048TLC3D-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

86824 – GEM50MLTLC3D-5

Quick Reference
Guides

gelighting.com

Metal Halide

Metal Halide

For 20 – 175W Metal Halide HID Lamps

For 20 – 175W Metal Halide HID Lamps

Metal Halide
1 – 100W MH M90 or M140 480

General characteristics

Dimensions

General characteristics

Wiring diagram HID W-(F)-87068-86667 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
3.0
Weight
5.00 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Electrical characteristics

Supply Current Frequency

Order information
No. Items Per Standard Package
6

150W Quartz
Metal Halide

0.56 A
0.33 A
271V
384V
90
-22 / -30
2
C

cUL Listed

General characteristics

Dimensions

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 Volt) featuring a 480-Volt tap

87210 – GEM175ML5AC3-5
Metal Halide
1 – 175W MH M57 or H39 5-Tap (120/208/240/277/480V)

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
M57, H39, M109
120/208/240/277/480
10%
CWA
180C
Oil filled
10 Mfd
400
100°C (212°F)

Supply Current Frequency

Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.0
B
4.0
Weight
3.40 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in
Lead lengths
Orange
Violet and Black
Violet/White
Black/Yellow

60 Hz

Order information
No. Items Per Standard Package
6

Type
Distributor Kit

Specifications by lamp and line voltage
240
186
0.80 A
1
0.81
1.68 A
0.89 A
257V
192V
90
-22 / -30
5
A

Lamp
M57, H39, M109

277
186
0.70 A
1
0.81
1.39 A
0.77 A
257V
222V
90
-22 / -30
4
A

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

See page 195 for warranty information.

120
202
1.70 A
1
0.87
1.70 A
0.60 A
307V
96V
90
-22 / -30
5
D

cUL Listed

See page 195 for warranty information.

208
202
1.00 A
1
0.87
1.00 A
0.37 A
307V
166V
90
-22 / -30
3
C

240
202
0.90 A
1
0.87
0.90 A
0.32 A
307V
192V
90
-22 / -30
3
C

277
202
0.80 A
1
0.87
0.80 A
0.28 A
307V
222V
90
-22 / -30
2
C

480
202
0.40 A
1
0.87
0.40 A
0.21 A
307V
384V
90
-22 / -30
1.5
C

UL Listed

147

HID Electromagnetic
Ballasts

cUL Listed

208
186
1.00 A
1
0.81
1.95 A
1.03 A
257V
166V
90
-22 / -30
5
B

No. Items Per Standard Package
6

Specifications by lamp and line voltage

Specifications by line voltage
120
186
1.60 A
1
0.81
3.37 A
1.86 A
257V
96V
90
-22 / -30
10
A

No. Items Per Sales Unit
1

HID Electronic
Ballasts

No. Items Per Sales Unit
1

480
185
0.40 A
1
0.83
0.85 A
0.38 A
264V
384V
90
-22 / -30
2
E

UL Listed

Electrical characteristics
60 Hz

Order information

146

cUL Listed

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

General characteristics

Wiring diagram HID W-(H)-86675-86718 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.3
B
4.0
Weight
7.00 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Electrical characteristics

Safety and performance

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Specifications by line voltage

Compact Fluorescent
Ballasts

Magnetic – Core and Coil
M142, M102
120/208/240/277
5%
HX-HPF
180C
Dry film
16 Mfd
300
100°C (212°F)
MH350-1A

Lamp
M107

480
185
0.40 A
1
0.81
0.85 A
0.38 A
264V
384V
90
-22 / -30
2
E

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

1 – 150W MH M102 or M142 Quad (120/208/240/277V)

150W
Quartz
Metal Halide

Specifications by line voltage

Safety and performance

UL Listed

Metal Halide

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Standard Package
6

T12
Fluorescent Ballasts

Lamp
M102, M142
150W Ceramic
Metal Halide

480
120
0.30 A
1

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Sales Unit
1

Specifications by lamp and line voltage

Specifications by line voltage

86718 – GEM150MLTLC3D-5

Lamp
M142, M102
150W
Ceramic
Metal Halide

60 Hz

Type
Distributor Kit

Specifications by lamp and line voltage

Type
Distributor Kit

Wiring diagram HID W-(E)-87087-86711-86876 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.3
B
3.9
Weight
7.00 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Order information
No. Items Per Sales Unit
1

Supply Current Frequency

Magnetic – Core and Coil
M142, M102, M107
480
5%
HX-HPF
180C
Dry film
16 Mfd
280
100°C (212°F)
MH350-1A

Electrical characteristics
60 Hz

Type
Distributor Kit

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Magnetic – Core and Coil
M90 or M140
480
5%
HX-HPF
180C
Dry film
12 Mfd
280
100°C (212°F)
MH350-1A

Supply Current Frequency

Safety and performance

Metal Halide
1 – 150W MH M102 or M142 480

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Lamp
M90, M140
100W Ceramic
Metal Halide

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86711 – GEM15048TLC3D-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86667 – GEM10048TLC3D-5

Quick Reference
Guides

gelighting.com

Metal Halide

Metal Halide

For 20 – 175W Metal Halide HID Lamps

For 250 – 1500W Metal Halide HID Lamps

Metal Halide
1 – 175W MH M57 or H39 Quad (120/208/240/277V)

General characteristics

Dimensions
Magnetic – Core and Coil
M57, M107, H39
120/208/240/277
10%
CWA
180C
Oil filled
10 Mfd
400
100°C (212°F)

60 Hz

60 Hz

Order information
Type
Distributor Kit

No. Items Per Standard Package
6

cUL Listed

No. Items Per Standard Package
6

208
210
1.00 A
1
0.83
1.00 A
0.56 A
302V
166V
90
-22 / -30
3
B

240
210
0.90 A
1
0.83
0.90 A
0.48 A
302V
192V
90
-22 / -30
3
B

277
210
0.80 A
1
0.83
0.80 A
0.42 A
302V
222V
90
-22 / -30
2
C

Lamp
M107

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power factor (>=) %
Min. starting temperature
Fuse rating
UL bench top rise

120
210
1.80 A
1

208
210
1.00 A
1

240
210
0.90 A
1

277
210
0.80 A
1

1.80 A
0.96 A
302V
96V
90
-22 / -30
5
B

1.00 A
0.56 A
302V
166V
90
-22 / -30
3
B

0.90 A
0.48 A
302V
192V
90
-22 / -30
3
B

0.80 A
0.42 A
302V
222V
90
-22 / -30
2
C

Lamp
M58, H37
250W Quartz
Metal Halide

Specifications by line voltage

System Wattage (W)
Nominal Current
Ballast Factor
175W Quartz
Ballast Efficiency Factor
Metal Halide) Max Input Current
250W Mercury Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

120
280
2.50 A
1
0.89
2.60 A
1.50 A
290V
96V
90
-22 / -30
8
B

Safety and performance

cUL Listed

208
280
1.40 A
1
0.89
1.60 A
1.00 A
290V
166V
90
-22 / -30
5
B

240
280
1.25 A
1
0.89
1.30 A
0.80 A
290V
192V
90
-22 / -30
4
B

277
280
1.10 A
1
0.89
1.20 A
0.70 A
290V
222V
90
-22 / -30
3
C

T12
Fluorescent Ballasts

120
210
1.80 A
1
0.83
1.80 A
0.96 A
302V
96V
90
-22 / -30
5
B

No. Items Per Sales Unit
1

Specifications by lamp and line voltage

Specifications by line voltage

Safety and performance

Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.0
B
4.3
Weight
9.00 lbs
Exit Type
Side
Nominal Length
3.2 in (82.55 mm)
Frame Size (H x L)
2.813 in x 3.939 in
Lead lengths
Orange
Violet and Black
Violet/White
Black/Yellow

Electrical characteristics

No. Items Per Sales Unit
1

System Wattage (W)
Nominal Current
Ballast Factor
150W Quartz
Ballast Efficiency Factor
Metal Halide Max Input Current
175W Mercury Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=) %
Min. Starting Temp
Fuse Rating
UL Bench Top Rise

Magnetic – Core and Coil
M58, H37
120/208/240/277/480
10%
CWA
180C
Oil filled
15 Mfd
400
100°C (212°F)

Supply Current Frequency

Specifications by lamp and line voltage
Lamp
M57, H39
175W Quartz
Metal Halide

Dimensions

General characteristics

Order information
Type
Distributor Kit

1 – 250W MH M58 or H37 5-Tap (120/208/240/277/480V)
Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Wiring diagram HID W-(C)-86655-86698-86741 – see example on page 181
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
1.0
B
2.0
Weight
3.40 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Electrical characteristics
Supply Current Frequency

Metal Halide

T5
Fluorescent Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

87211 – GEM250ML5AC3-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

86741 – GEM175MLTAC3-5

Quick Reference
Guides

gelighting.com

480
280
0.65 A
1
0.89
0.70 A
0.50 A
290V
384V
90
-22 / -30
2
C

UL Listed

UL Listed

Metal Halide
1 – 250W MH M58 or H37 Quad (120/208/240/277V)

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

86765 – GEM250MLTAC3-5

Dimensions

General characteristics
Magnetic – Core and Coil
M58, H37
120/208/240/277
10%
CWA
180C
Oil filled
15 Mfd
400
100°C (212°F)

Wiring diagram HID W-(C)-86765-86814 – see example on page 181
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.0
B
4.3
Weight
9.00 lbs
Exit Type
Side
Nominal Length
3.2 in (82.55 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Compact Fluorescent
Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
No. Items Per Sales Unit
1

HID Electronic
Ballasts

Type
Distributor Kit

No. Items Per Standard Package
6

Specifications by lamp and line voltage

Safety and performance
148

See page 195 for warranty information.

120
294
2.65 A
1
0.85
2.60 A
1.88 A
315V
96V
90
-22 / -30
8
C
cUL Listed

See page 195 for warranty information.

208
294
1.50 A
1
0.85
1.58 A
1.15 A
315V
166V
90
-22 / -30
5
D

240
294
1.30 A
1
0.85
1.30 A
0.95 A
315V
192V
90
-22 / -30
4
C

277
294
1.13 A
1
0.85
1.12 A
0.86 A
315V
222V
90
-22 / -30
3
C

UL Listed

149

HID Electromagnetic
Ballasts

Lamp
Specifications by line voltage
M58, H37
250W Quartz System Wattage (W)
Metal Halide Nominal Current
Ballast Factor
175W Quartz Ballast Efficiency Factor
Metal Halide Max Input Current
250W Mercury Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Metal Halide

Metal Halide

For 250 – 1500W Metal Halide HID Lamps

For 250 – 1500W Metal Halide HID Lamps

Metal Halide
1 – 250W MH M58 or H37 5-Tap (120/208/240/277/480V)

Dimensions

General characteristics
Magnetic – Core and Coil
M58, H37
120/208/240/277/480
10%
CWA
180C
Oil filled
15 Mfd
400
100°C (212°F)

60 Hz

Order information
Type
Distributor Kit

No. Items Per Sales Unit
1

No. Items Per Standard Package
3

Safety and performance

cUL Listed

208
293
2.30 A
1
0.85
1.40 A
1.40 A
300V
166V
90
-22 / -30
5
A

240
293
2.00 A
1
0.85
1.30 A
1.20 A
300V
192V
90
-22 / -30
4
A

277
293
1.70 A
1
0.85
1.10 A
1.00 A
300V
222V
90
-22 / -30
3
A

480
293
1.00 A
1
0.85
0.65 A
0.60 A
300V
384V
90
-22 / -30
2
A

360W Quartz
Metal Halide
400W Mercury

Dimensions

General characteristics

60 Hz

Order information

360W Quartz
Metal Halide
400W Mercury

150

cUL Listed

120
446
3.80 A
1
0.93
3.80 A
3.17 A
289V
96V
90
-22 / -30
10
C

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise
cUL Listed

208
446
2.20 A
1
0.93
2.20 A
1.84 A
289V
166V
90
-22 / -30
8
C

240
446
1.90 A
1
0.93
1.90 A
1.60 A
289V
192V
90
-22 / -30
5
C

277
446
1.70 A
1
0.93
1.70 A
1.39 A
289V
222V
90
-22 / -30
5
C

UL Listed

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86803 – GEM40048TAC4-5
Metal Halide
1 – 400W MH M59 or H33 480

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
M59, H33
480
10%
CWA
180C
Oil filled
24 Mfd
400
100°C (212°F)

Wiring diagram HID W-(J)-86650-86693-86803 – see example on page 182
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
12.50 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 4.75 in

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
No. Items Per Sales Unit
1

No. Items Per Standard Package
3

Specifications by lamp and line voltage
208
446
2.10 A
1
0.92
2.10 A
1.31 A
300V
166V
90
-22 / -30
8
E

240
446
1.90 A
1
0.92
1.90 A
1.11 A
300V
192V
90
-22 / -30
5
E

277
446
1.60 A
1
0.92
1.60 A
1.00 A
300V
222V
90
-22 / -30
5
E

Lamp
M59
400W Quartz
Metal Halide

480
446
0.90 A
1
0.92
0.90 A
0.60 A
300V
384V
90
-22 / -30
5
E

360W Quartz
Metal Halide

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

See page 195 for warranty information.

cUL Listed

See page 195 for warranty information.

480
432
0.90 A
1
0.93
0.90 A
0.60 A
297V
384V
90
-22 / -30
5
A

Lamp
H33
400W Mercury

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

480
458
1.00 A
1
0.87
1.00 A
0.60 A
300V
384V
90
-22 / -30
5
E

UL Listed

151

HID Electromagnetic
Ballasts

Safety and performance

Specifications by line voltage

Type
Distributor Kit

Specifications by line voltage
120
446
3.70 A
1
0.92
3.70 A
2.19 A
300V
96V
90
-22 / -30
10
E

No. Items Per Standard Package
3

HID Electronic
Ballasts

No. Items Per Standard Package
3

Specifications by lamp and line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Sales Unit
1

General characteristics

Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
12.50 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 4.75 in
Lead lengths
Orange
Violet and Black
Violet/White
Black/Yellow

Electrical characteristics

Lamp
M59, H33
400W Quartz
Metal Halide

60 Hz

Compact Fluorescent
Ballasts

Magnetic – Core and Coil
M59, H33
120/208/240/277/480
10%
CWA
180C
Oil filled
24 Mfd
400
100°C (212°F)

No. Items Per Sales Unit
1

0.25 in (6.35 mm)
2.0
4.0
11.90 lbs
Side
3.7 in (95.25 mm)
4.25 in x 4.75 in

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 Volt) featuring a 480-Volt tap

1 – 400W MH M59 or H33 5-Tap (120/208/240/277/480V) A1 C&C

Type
Distributor Kit

4.6 in (116.84 mm)

Order information

Safety and performance

Metal Halide

Supply Current Frequency

5.25 in (133.35 mm)
1.25 in (31.75 mm)

Electrical characteristics
Supply Current Frequency

Lamp
M59, H33
400W Quartz
Metal Halide

UL Listed

72300 – GEM400ML5AA4-5

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Wiring diagram HID H21 – see example on page 180
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
Width (W)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
A
B
Weight
Exit Type
Nominal Length
Frame Size (H x L)

T12
Fluorescent Ballasts

120
293
4.00 A
1
0.85
2.50 A
2.50 A
300V
96V
90
-22 / -30
8
A

Magnetic – Core and Coil
M59, H33
120/208/240/277
10%
CWA
180C
Oil filled
24 Mfd
400
100°C (212°F)

Specifications by lamp and line voltage

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Type
Distributor Kit

Specifications by lamp and line voltage
Lamp
M58, H37

1 – 400W MH M59 or H33 Quad (120/208/240/277V) A1 C&C

General characteristics

Wiring diagram HID W-(K)-87212-87213 – see example on page 183
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
1.8
B
3.6
Weight
10.80 lbs
Exit Type
Side
Nominal Length
3.2 in (82.55 mm)
Frame Size (H x L)
4.25 in x 4.75 in
Lead lengths
Orange
Violet and Black
Violet/White
Black/Yellow

Electrical characteristics
Supply Current Frequency

Metal Halide

T5
Fluorescent Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

72149 – GEM400MLTAA4-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

87212 – GEM250ML5AC4-5

Quick Reference
Guides

gelighting.com

Metal Halide

Metal Halide

For 250 – 1500W Metal Halide HID Lamps

For 250 – 1500W Metal Halide HID Lamps

Metal Halide
1 – 1000W MH M47 or H36 480

Dimensions

General characteristics

Electrical characteristics

No. Items Per Standard Package
2

cUL Listed

1000W Mercury

Dimensions

General characteristics

60 Hz

No. Items Per Sales Unit
1

1 – 1500W MH M48 480

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
M48
480
10%
CWA
180C
Oil filled
32 Mfd
525
100°C (212°F)

Wiring diagram HID W-(J)-86650-86693-86803 – see example on page 182
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
7.75 in (196.85 mm)
Width (W)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
4.0
B
6.0
Weight
30.00 lbs
Exit Type
Side
Nominal Length
5.2 in (133.35 mm)
Frame Size (H x L)
4.25 in x 6.00 in

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
No. Items Per Sales Unit
1

No. Items Per Standard Package
2

Specifications by lamp and line voltage
208
1,103
5.40 A
1
0.91
5.40 A
3.71 A
445V
166V
90
-22 / -30
15
C

240
1,103
4.70 A
1
0.91
4.70 A
3.20 A
445V
192V
90
-22 / -30
10
C

277
1,103
4.10 A
1
0.91
4.10 A
2.79 A
445V
222V
90
-22 / -30
10
C

480
1,103
2.40 A
1
0.91
2.40 A
1.65 A
445V
384V
90
-22 / -30
10
D

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

See page 195 for warranty information.

cUL Listed

See page 195 for warranty information.

480
1,581
3.10 A
1
0.95
3.10 A
3.18 A
449V
384V
90
-22 / -30
10
G
UL Listed

153

HID Electromagnetic
Ballasts

cUL Listed

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

Metal Halide

Lamp
M48
1500W Quartz
Metal Halide

Specifications by line voltage
120
1,103
9.30 A
1
0.91
9.30 A
6.34 A
445V
96V
90
-22 / -30
20
E

UL Listed

86693 – GEM150048TAC5M5-5

Type
Distributor Kit

No. Items Per Standard Package
2

Specifications by lamp and line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

277
1,067
3.90 A
1
0.94
3.90 A
3.30 A
421V
222V
90
-22 / -30
10
B

HID Electronic
Ballasts

Order information
Type
Distributor Kit

240
1,067
4.50 A
1
0.94
4.50 A
3.79 A
421V
192V
90
-22 / -30
10
B

General characteristics

Wiring diagram HID W-(K)-87212-87213 – see example on page 183
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
7.75 in (196.85 mm)
Width (W)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.0
B
5.0
Weight
21.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 6.00 in
Lead lengths
Orange
Violet and Black
Violet/White
Black/Yellow

Electrical characteristics

cUL Listed

208
1,067
5.00 A
1
0.94
5.00 A
4.35 A
421V
166V
90
-22 / -30
15
B

Compact Fluorescent
Ballasts

Magnetic – Core and Coil
M47, H36
120/208/240/277/480
10%
CWA
180C
Oil filled
24 Mfd
480
100°C (212°F)

120
1,067
9.00 A
1
0.94
9.00 A
7.44 A
421V
96V
90
-22 / -30
20
B

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 Volt) featuring a 480-Volt tap

1 – 1000W MH M47 or H36 5-Tap (120/208/240/277/480V)

Supply Current Frequency

Specifications by line voltage

Safety and performance

UL Listed

Metal Halide
Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

No. Items Per Standard Package
2

T12
Fluorescent Ballasts

480
1,052
2.20 A
1
0.95
2.20 A
1.83 A
430V
384V
90
-22 / -30
10
E

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Sales Unit
1

Specifications by lamp and line voltage
Lamp
M47, H36
1000W Quartz
Metal Halide

87213 – GEM1000ML5AA5-5

152

60 Hz

Type
Distributor Kit

Specifications by line voltage

Safety and performance

Wiring diagram HID W-(C)-86655-86698-86741 – see example on page 181
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
7.75 in (196.85 mm)
Width (W)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.0
B
5.0
Weight
21.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 6.00 in

Order information
No. Items Per Sales Unit
1

Specifications by lamp and line voltage

1000W Mercury

Magnetic – Core and Coil
M47, H36
120/208/240/277
10%
CWA
180C
Oil filled
24 Mfd
480
100°C (212°F)

Supply Current Frequency

Order information

Lamp
M47, H36
1000W Quartz
Metal Halide

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics
60 Hz

Type
Distributor Kit

Safety and performance

Dimensions

General characteristics

Wiring diagram HID W-(J)-86650-86693-86803 – see example on page 182
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
7.75 in (196.85 mm)
Width (W)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.0
B
5.0
Weight
21.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 6.00 in

T5
Fluorescent Ballasts

Magnetic – Core and Coil
M47, H36
480
10%
CWA
180C
Oil filled
24 Mfd
480
100°C (212°F)

Supply Current Frequency

1000W Mercury

Metal Halide
1 – 1000W MH M47 or H36 Quad (120/208/240/277V)

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Lamp
M47, H36
1000W Quartz
Metal Halide

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

86655 – GEM1000MLTAA5-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications.
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity.
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86650 – GEM100048TAC5-5

Quick Reference
Guides

gelighting.com

Metal Halide

Pulse Start

For 250 – 1500W Metal Halide HID Lamps

For 175 – 1000W Pulse Start Metal Halide HID Lamps

Metal Halide
1 – 1500W MH M48 Quad (120/208/240/277V)

Dimensions

General characteristics
Magnetic – Core and Coil
M48
240/277
10%
CWA
180C
Oil filled
32 Mfd
525
100°C (212°F)

1 – 175W PS M137 or M152 Quad (120/208/240/277V)

Dimensions

General characteristics

Wiring diagram HID W-(C)-86655-86698-86741 – see example on page 181
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
7.75 in (196.85 mm)
Width (W)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
4.0
B
6.0
Weight
30.00 lbs
Exit Type
Side
Nominal Length
5.2 in (133.35 mm)
Frame Size (H x L)
4.25 in x 6.00 in

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
M153, M137
120/208/240/277
10%
CWA
180C
Oil filled
10 Mfd
400
100°C (212°F)
MH350-1A

Wiring diagram HID W-(A)-46934-86885-86935 – see example on page 181
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
7.50 lbs
Exit Type
Side
Nominal Length
3.2 in (82.55 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Electrical characteristics

Electrical characteristics
Supply Current Frequency

Supply Current Frequency

60 Hz

60 Hz

Order information

Order information
Type
Distributor Kit

No. Items Per Sales Unit
1

Type
Distributor Kit

No. Items Per Standard Package
2

cUL Listed

208
1,602
7.70 A
1
0.94
7.70 A
7.46 A
440V
166V
90
-22 / -30
25
A

No. Items Per Standard Package
6

240
1,602
6.80 A
1
0.94
6.80 A
6.52 A
440V
192V
-22 / -30
20
A

Lamp
M153
250W
Quartz
Metal
Halide

277
1,602
6.00 A
1
0.94
6.00 A
5.75 A
440V
222V
90
-22 / -30
20
A

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=) %
Min. Starting Temp
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

120
204
1.70 A
1
1.23
1.70 A
0.76 A
281V
96V
90
-22 / -30
5
C

208
204
1.00 A
1
1.23
1.00 A
0.36 A
281V
166V
90
-22 / -30
3
D

cUL Listed

240
204
0.90 A
1
1.23
0.90 A
0.38 A
281V
192V
90
-22 / -30
3
B

277
204
0.80 A
1
1.23
0.80 A
0.33 A
281V
222V
90
-22 / -30
2
B

Lamp
M137
175W Quartz
Metal Halide

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power factor (>=) %
Min. starting temperature
Fuse rating
UL bench top rise

120
204
1.70 A
1
0.86
1.70 A
0.76 A
281V
96V
90
-22 / -30
5
C

208
204
1.00 A
1
0.86
1.00 A
0.36 A
281V
166V
90
-22 / -30
3
D

240
204
0.90 A
1
0.86
0.90 A
0.38 A
281V
192V
90
-22 / -30
3
B

277
204
0.80 A
1
0.86
0.80 A
0.33 A
281V
222V
90
-22 / -30
2
B

T12
Fluorescent Ballasts

120
1,602
13.70 A
1
0.94
13.70 A
12.95 A
440V
96V
90
-22 / -30
40
E

No. Items Per Sales Unit
1

Specifications by lamp and line voltage

Specifications by lamp and line voltage
Specifications by line voltage
Lamp
M48
1500W Quartz System Wattage (W)
Nominal Current
Metal Halide
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

Pulse Start

T5
Fluorescent Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

86885 – GEP175MLTAC3-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

86698 – GEM1500MLTAC5-5

Quick Reference
Guides

gelighting.com

UL Listed

Pulse Start

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86876 – GEP17548TAC3-5
1 – 175W PS M137 or M152 480

Dimensions

General characteristics
Magnetic – Core and Coil
M152, M137
120/480
10%
CWA
180C
Oil filled
10 Mfd
400
100°C (212°F)
MH350-1A

Wiring diagram HID W-(E)-87087-86711-86876 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
7.00 lbs
Exit Type
Side
Nominal Length
3.2 in (82.55 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Compact Fluorescent
Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics
Supply Current Frequency

60 Hz

Type
Distributor Kit

No. Items Per Sales Unit
1

HID Electronic
Ballasts

Order information
No. Items Per Standard Package
6

Specifications by lamp and line voltage
Lamp
M152, M137
175W Quartz
Metal Halide

Specifications by line voltage

Safety and performance
154

See page 195 for warranty information.

cUL Listed

See page 195 for warranty information.

120
210
1.85 A
1
0.83

480
214
0.50 A
1
0.82
0.50 A
0.14 A
273V

0.55 A
315V
96V
90
384V
2
C

90
-22 / -30
2
C
UL Listed

155

HID Electromagnetic
Ballasts

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Pulse Start

Pulse Start

For 175 – 1000W Pulse Start Metal Halide HID Lamps

For 175 – 1000W Pulse Start Metal Halide HID Lamps

Pulse Start
1 – 250W PS M138 or M153 Quad (120/208/240/277V)

Dimensions

General characteristics
Magnetic – Core and Coil
M153, M138
120/208/240/277
10%
CWA
180C
Oil filled
15 Mfd
400
100°C 212°F)
MH350-1A

Wiring diagram HID W-(A)-86959-86984-87008 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Slots (MS) Mount Width (X or F)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
11.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 4.75 in

60 Hz

Order information
No. Items Per Sales Unit
1

No. Items Per Standard Package
3

Type
Distributor Kit

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

cUL Listed

No. Items Per Standard Package
3

208
284
1.40 A
1
0.88
1.40 A
1.02 A
255V
166V
90
-22 / -30
5
A

240
284
1.30 A
1
0.88
1.30 A
0.89 A
255V
192V
90
-22 / -30
5
A

277
284
1.10 A
1
0.88
1.10 A
0.77 A
255V
222V
90
-22 / -30
3
B

Specifications by line voltage

Safety and performance

UL Listed

Pulse Start
1 – 250W PS M138 or M153 480

cUL Listed

208
370
1.80 A
1
0.86
1.80 A
1.04 A
269V
166V
90
-22 / -30
7
B

240
370
1.60 A
1
0.86
1.60 A
0.87 A
269V
192V
90
-22 / -30
5
B

277
370
1.40 A
1
0.86
1.40 A
0.76 A
269V
222V
90
-22 / -30
5
A

UL Listed

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86952 – GEP32048TAC4M-5
Pulse Start

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86926 – GEP25048TAC4-5

120
370
3.10 A
1
0.86
3.10 A
1.75 A
269V
96V
90
-22 / -30
8
D

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

T12
Fluorescent Ballasts

Lamp
M154, M132

Specifications by line voltage
120
284
2.50 A
1
0.88
2.50 A
1.78 A
255V
96V
90
-22 / -30
8
A

No. Items Per Sales Unit
1

Specifications by lamp and line voltage

Specifications by lamp and line voltage

1 – 320W PS M132 or M154 480

Dimensions

General characteristics
Magnetic – Core and Coil
M153, M138
480
10%
CWA
180C
Oil filled
15 Mfd
400
100°C (212°F)
MH350-1A

Dimensions

General characteristics

Wiring diagram HID W-(E)-86926 – see example on page 182
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
3.0
Weight
9.00 lbs
Exit Type
Side
Nominal Length
3.2 in (82.55 mm)
Frame Size (H x L)
4.25 in x 4.75 in

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
M154, M132
480
10%
CWA
180C
Oil filled
21 Mfd
345
100°C (212°F)
MH350-1A

Wiring diagram HID W-(D)-86952-86999 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Height (H)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
12.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 4.75 in

Electrical characteristics

Electrical characteristics
Supply Current Frequency

Supply Current Frequency

60 Hz

Compact Fluorescent
Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

60 Hz

Order information
No. Items Per Sales Unit
1

Type
Distributor Kit

No. Items Per Standard Package
3

Specifications by lamp and line voltage
Specifications by line voltage

cUL Listed

480
290
0.60 A
1
0.86
0.60 A
0.48 A
254V
384V
90
-22 / -30
2
C

No. Items Per Standard Package
3

Specifications by lamp and line voltage
Lamp
M138

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Lamp
M154, M132

480
290
0.60 A
1

Specifications by line voltage
480
369
0.80 A
1
0.87
0.80 A
0.50 A
268V
384V
90
-22 / -30
3
C

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

0.60 A
0.48 A
254V
384V
90
-22 / -30
2
C

Safety and performance

UL Listed

See page 195 for warranty information.

cUL Listed

See page 195 for warranty information.

UL Listed

157

HID Electromagnetic
Ballasts

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Sales Unit
1

HID Electronic
Ballasts

Order information
Type
Distributor Kit

156

Magnetic – Core and Coil
M154, M132
120/208/240/277
10%
CWA
180C
Oil filled
21 Mfd
345
100°C (212°F)
MH350-1A

Supply Current Frequency

Order information

Safety and performance

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics
60 Hz

Type
Distributor Kit

Lamp
M153
250W Quartz
Metal Halide

1 – 320W PS M132 or 154 Quad (120/208/240/277V)

General characteristics

Wiring diagram HID W-(A)-46934-86885-86935 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
3.0
Weight
9.00 lbs
Exit Type
Side
Nominal Length
3.2 in (82.55 mm)
Frame Size (H x L)
4.25 in x 4.75 in

Electrical characteristics
Supply Current Frequency

Lamp
M153, M138
250W Quartz
Metal Halide

Pulse Start

T5
Fluorescent Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

86959 – GEP320MLTAC4-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

86935 – GEP250MLTAC4-5

Quick Reference
Guides

gelighting.com

Pulse Start

Pulse Start

For 175 – 1000W Pulse Start Metal Halide HID Lamps

For 175 – 1000W Pulse Start Metal Halide HID Lamps

Pulse Start
1 – 320W PS M132 or M154 TRI-Voltage 120 277 347

Dimensions

Electrical characteristics

No. Items Per Standard Package
3

cUL Listed

277
400
1.30 A
1
0.88
1.30 A
0.83 A
281V
222V
90
-22 / -30
4
C

Lamp
M155, M135
400W Quartz
Metal Halide

347
400
1.10 A
1
0.88
1.10 A
0.66 A
281V
150V
90
-22 / -30
3
C

Specifications by line voltage

Pulse Start
1 – 350W PS M131 Quad (120/208/240/277V)

Dimensions

General characteristics

UL Listed

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

87008 – GEP400MLTAC4-5
Pulse Start
1 – 400W PS M135 or M155 Quad (120/208/240/277V)

Dimensions

General characteristics

Wiring diagram HID W-(A)-86959-86984-87008 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
12.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 4.75 in

Electrical characteristics

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
M155, M135
120/208/240/277
10%
CWA
180C
Oil filled
24 Mfd
400
100°C (212°F)
MH350-1A

Wiring diagram HID W-(A)-86959-86984-87008 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
3.8
Weight
12.00 lbs
Exit Type
Side
Nominal Length
4.6 in (119.12 mm)
Frame Size (H x L)
4.25 in x 4.75 in

Compact Fluorescent
Ballasts

Magnetic – Core and Coil
M131
120/208/240/277
10%
CWA
180C
Oil filled
21.5 Mfd
345
100°C (212°F)
MH350-1A

cUL Listed

Electrical characteristics

Supply Current Frequency

60 Hz

Supply Current Frequency

Order information

60 Hz

No. Items Per Sales Unit
1

No. Items Per Standard Package
3

Type
Distributor Kit

Specifications by lamp and line voltage
240
396
1.70 A
1
0.88
1.70 A
1.12 A
262V
192V
90
-22 / -30
5
D

Lamp
M155, M135
400W Quartz
Metal Halide

277
396
1.40 A
1
0.88
1.40 A
0.99 A
262V
222V
90
-22 / -30
5
D

UL Listed

See page 195 for warranty information.

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

120
443
3.90 A
1
0.90
3.90 A
3.16 A
259V
96V
90
-22 / -30
10
B

Safety and performance

cUL Listed

See page 195 for warranty information.

208
443
2.20 A
1
0.90
2.20 A
1.85 A
259V
166V
90
-22 / -30
7
C

240
443
2.00 A
1
0.90
2.00 A
1.60 A
259V
192V
90
-22 / -30
5
D

277
443
1.70 A
1
0.90
1.70 A
1.39 A
259V
222V
90
-22 / -30
5
C

UL Listed

159

HID Electromagnetic
Ballasts

cUL Listed

208
396
1.90 A
1
0.88
1.90 A
1.31 A
262V
166V
90
-22 / -30
7
D

No. Items Per Standard Package
3

Specifications by lamp and line voltage

Specifications by line voltage
120
396
3.40 A
1
0.88
3.40 A
2.31 A
262V
96V
90
-22 / -30
10
D

No. Items Per Sales Unit
1

HID Electronic
Ballasts

Order information

Type
Distributor Kit

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

480
465
1.00 A
1
0.86
1.00 A
0.80 A
275V
384V
90
-22 / -30
3
D

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

86984 – GEP350MLTAC4-5

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

No. Items Per Standard Package
3

T12
Fluorescent Ballasts

120
400
3.00 A
1
0.88
3.00 A
1.89 A
281V
96V
90
-22 / -30
8
C

No. Items Per Sales Unit
1

Specifications by lamp and line voltage

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

158

60 Hz

Type
Distributor Kit

Specifications by lamp and line voltage

Safety and performance

Wiring diagram HID W-(D)-86952-86999 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
12.00 lbs
Exit Type
Side
Nominal Length
4.6 in (119.12 mm)
Frame Size (H x L)
4.25 in x 4.75 in

Order information
No. Items Per Sales Unit
1

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Magnetic – Core and Coil
M155, M135
480
10%
CWA
180C
Oil filled
24 Mfd
400
100°C (212°F)
MH350-1A

Supply Current Frequency

Order information

Lamp
M131
350W Quartz
Metal Halide

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics
60 Hz

Type
Distributor Kit

Safety and performance

Dimensions

General characteristics

Wiring diagram HID W-(L)-86968 – see example on page 183
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.3 in (134.62 mm)
Width (W)
1.3 in (33.02 mm)
Mounting dimensions
Mount Length (M)
4.60 in (116.84 mm)
Mount Slots (MS)
0.3 in (7.62 mm)
A
B
Weight
12.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in (4.75 mm)

T5
Fluorescent Ballasts

Magnetic – Core and Coil
M154, M132
120/277/347
10%
CWA
180C
Oil Filled
21 Mfd
400
100°C (212°F)
MH350-1A

Supply Current Frequency

Lamp
M154, M132

Pulse Start
1 – 400W PS M135 or M155 480

General characteristics
Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86999 – GEP40048TAC4-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86968 – GEP320TRIAC4-5

Quick Reference
Guides

gelighting.com

Pulse Start

Pulse Start

For 175 – 1000W Pulse Start Metal Halide HID Lamps

For 175 – 1000W Pulse Start Metal Halide HID Lamps

Pulse Start
1 – 750W PS M149 480

Dimensions

General characteristics

Electrical characteristics

No. Items Per Standard Package
2

60 Hz

Type
Distributor Kit

Specifications by lamp and line voltage

cUL Listed

UL Listed

1 – 750W PS M149 Quad (120/208/240/277V)

Dimensions

General characteristics

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

120
1071
8.80 A
1
0.93
8.80 A
5.70 A
420V
96V
90
-22 / -30
20
D

Safety and performance

cUL Listed

208
1071
5.10 A
1
0.93
5.10 A
5.70 A
420V
166V
90
-22 / -30
15
B

240
1071
4.30 A
1
0.93
4.30 A
5.70 A
420V
192V
90
-22 / -30
10
B

277
1071
4.00 A
1
0.93
4.00 A
5.70 A
420V
222V
90
-22 / -30
10
B

UL Listed

72282 – GEP1000ML5AC5-5
Pulse Start
1 – 1000W PS M141 5-Tap (120/208/240/277/480V)

Dimensions

General characteristics

Wiring diagram HID W-(A)-46934-86885-86935 – see example on page 181
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
7.75 in (196.85 mm)
Width (W)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.0
B
5.0
Weight
22.00 lbs
Exit Type
Side
Nominal Length
4.2 in (107.95 mm)
Frame Size (H x L)
4.25 in x 6.00 in

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
M141
120/208/240/277/480
10%
CWA
180C
Oil filled
24 Mfd
480
-30°C (-20°F)
HPS1000-4B
D (37-42 decibels)

Wiring diagram HID W-(A)-87214-87215-87218 – see example on page 181
Case dimensions – Ref Drawing PC3 – see page 185
Width (W)
7.75 in (196.85 mm)
Length (L)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
6.1 in (154.94 mm)
Mount Slots (MS)
0.25 in (9.52 mm)
A
2.83
B
5.20
Weight
21.60 lbs
Exit Type
Side
Nominal Length
4.25 in (107.95 mm)
Frame Size (H x L)
4.25 in x 6.00 in

Compact Fluorescent
Ballasts

Magnetic – Core and Coil
M149
120/208/240/277
10%
CWA
180C
Oil filled
28 Mfd
400
100°C (212°F)
MH750-1A

Specifications by line voltage

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

Pulse Start
Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

No. Items Per Standard Package
2

T12
Fluorescent Ballasts

Lamp
M141

480
809
1.80 A
1
0.93
1.80 A
1.04 A
351V
384V
90
-22 / -30
6
E

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Sales Unit
1

Specifications by lamp and line voltage

Specifications by line voltage

46934 – GEP750MLTAC5-5

Electrical characteristics

Electrical characteristics
Supply Current Frequency

Supply Current Frequency

60 Hz

60 Hz

Order information
No. Items Per Sales Unit
1

Type
Distributor Kit

No. Items Per Standard Package
2

Lamp
M141

Specifications by line voltage
240
802
2.10 A
1
0.94
2.10 A
2.03 A
351V
192V
90
-22 / -30
8
B

277
802
1.80 A
1
0.94
1.80 A
1.76 A
351V
222V
90
-22 / -30
8
B

UL Listed

See page 195 for warranty information.

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

120
1112
9.30 A
1
0.90
9.30 A
5.70 A
450V
96V
90
-22 / -30
20
D

Safety and performance

cUL Listed

See page 195 for warranty information.

208
1112
5.40 A
1
0.90
5.40 A
5.70 A
450V
166V
90
-22 / -30
15
C

240
1112
4.70 A
1
0.90
4.70 A
5.70 A
450V
192V
90
-22 / -30
10
C

277
1112
4.20 A
1
0.90
4.20 A
5.70 A
450V
222V
90
-22 / -30
10
D

480
1112
2.50 A
1
0.90
2.50 A
5.70 A
450V
384V
90
-22 / -30
10
E

UL Listed

161

HID Electromagnetic
Ballasts

cUL Listed

208
802
2.40 A
1
0.94
2.40 A
2.32 A
351V
166V
90
-22 / -30
8
B

No. Items Per Standard Package
2

Specifications by lamp and line voltage

Specifications by lamp and line voltage
120
802
4.10 A
1
0.94
4.10 A
3.98 A
351V
96V
90
-22 / -30
15
B

No. Items Per Sales Unit
1

HID Electronic
Ballasts

Order information
Type
Distributor Kit

160

Wiring diagram HID W-(A)-46934-86935 – see example on page 181
Case dimensions – Ref Drawing PC3 – see page 185
Width (W)
7.75 in (196.85 mm)
Length (L)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
6.1 in (154.94 mm)
Mount Slots (MS)
0.25 in (9.52 mm)
A
2.83
B
5.08
Weight
21.00 lbs
Exit Type
Side
Nominal Length
4.25 in (107.95 mm)
Frame Size (H x L)
4.25 in x 6.00 in

Order information
No. Items Per Sales Unit
1

Safety and performance

Magnetic – Core and Coil
M141
120/208/240/277
10%
CWA
180C
Oil filled
24 Mfd
480
100°C (212°F)
HPS100-4B
D (37-42 decibels)

Supply Current Frequency

Order information

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics
60 Hz

Type
Distributor Kit

Lamp
M149
750W Quartz
Metal Halide

Dimensions

General characteristics

Wiring diagram HID W-(D)-87048-87198-49636 – see example on page 181
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
7.75 in (196.85 mm)
Width (W)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.0
B
5.0
Weight
21.00 lbs
Exit Type
Side
Nominal Length
4.2 in (107.95 mm)
Frame Size (H x L)
4.25 in x 6.00 in

T5
Fluorescent Ballasts

Magnetic – Core and Coil
M149
480
10%
CWA
180C
Oil filled
24 Mfd
480
100°C (212°F)
MH750-1A

Supply Current Frequency

Safety and performance

Pulse Start
1 – 1000W PS M141 Quad (120/208/240/277V)

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Lamp
M149
750W Quartz
Metal Halide

72281 – GEP1000MLTAC5-5
T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

46936 – GEP75048TAC5-5

Quick Reference
Guides

gelighting.com

High Pressure Sodium

High Pressure Sodium

For 50 – 150W High Pressure Sodium HID Lamps

For 50 – 150W High Pressure Sodium HID Lamps

High Pressure Sodium
1 – 50W HPS S68 Quad (120/208/240/277V)

General characteristics

Dimensions
Magnetic – Core and Coil
S68
120/208/240/277
5%
HX-HPF
180C
Dry film
5 Mfd
280
100°C (212°F)
HPS150-3A

cUL Listed

208
69
0.40 A
1
0.72
0.54 A
0.43 A
122V
166V
90
-22 / -30
3
B

240
69
0.30 A
1
0.72
0.46 A
0.37 A
122V
192V
90
-22 / -30
3
B

Lamp
S62
70W High
Pressure Sodium

277
69
0.30 A
1
0.72
0.40 A
0.32 A
122V
222V
90
-22 / -30
2
B

General characteristics

Dimensions

Specifications by line voltage
480
97
0.20 A
1
0.72
0.34 A
0.34 A
123V
384V
90
-22 / -30
2
A

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise
cUL Listed

UL Listed

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

87074 – GES100MLTLC3D-5
High Pressure Sodium
1 – 100W HPS S54 Quad (120/208/240/277V)

General characteristics

Wiring diagram HID W-(H)-86587-87074 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
3.0
Weight
5.50 lbs
Exit Type
Side
Nominal Length
2.7 in (69.85 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
S54
120/208/240/277
5%
HX-HPF
180C
Dry film
10 Mfd
280
100°C (212°F)
HPS150-3A 86635

Electrical characteristics
Supply Current Frequency

60 Hz

Wiring diagram HID W-(H)-86587-87074 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
6.20 lbs
Exit Type
Side
Nominal Length
2.7 in (69.85 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Compact Fluorescent
Ballasts

Magnetic – Core and Coil
S62
120/208/240/277
5%
HX-HPF
180C
Dry film
7 Mfd
300
100°C (212°F)
HPS150-3A

Electrical characteristics

60 Hz

Order information

Order information

Type
Distributor Kit

No. Items Per Standard Package
6

208
91
0.50 A
1
0.77
0.78 A
0.46 A
118V
166V
90
-22 / -30
3
B

240
91
0.40 A
1
0.77
0.67 A
0.39 A
118V
192V
90
-22 / -30
3
B

277
91
0.40 A
1
0.77
0.59 A
0.35 A
118V
222V
90
-22 / -30
2
B

150W High
Pressure Sodium

Specifications by line voltage

Safety and performance

UL Listed

See page 195 for warranty information.

120
123
2.20 A
1
1.22
2.18 A
0.74 A
119V
96V
90
-22 / -30
8
B

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

cUL Listed

See page 195 for warranty information.

208
123
1.30 A
1
1.22
1.27 A
0.43 A
119V
166V
90
-22 / -30
5
B

240
123
1.10 A
1
1.22
1.13 A
0.36 A
119V
192V
90
-22 / -30
5
B

277
123
0.90 A
1
1.22
0.94 A
0.31 A
119V
222V
90
-22 / -30
3
B

UL Listed

163

HID Electromagnetic
Ballasts

cUL Listed

No. Items Per Standard Package
6

Specifications by lamp and line voltage
Lamp
S54
100W High
Pressure Sodium

Specifications by line voltage
120
91
0.80 A
1
0.77
1.34 A
0.78 A
118V
96V
90
-22 / -30
5
B

No. Items Per Sales Unit
1

HID Electronic
Ballasts

No. Items Per Sales Unit
1

Specifications by lamp and line voltage

162

No. Items Per Standard Package
6

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

1 – 70W HPS S62 Quad (120/208/240/277V)

Supply Current Frequency

No. Items Per Sales Unit
1

Safety and performance

UL Listed

High Pressure Sodium

Safety and performance

0.25 in (6.35 mm)
2.0
3.0
5.80 lbs
Side
2.7 in (69.85 mm)
2.813 in x 3.939 in

T12
Fluorescent Ballasts

120
69
0.70 A
1
0.72
0.93 A
0.74 A
122V
96V
90
-22 / -30
5
B

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

4.6 in (116.84 mm)

Specifications by lamp and line voltage

86587 – GES70MLTLC3D-5

Lamp
S62
70W High
Pressure Sodium

5.25 in (133.35 mm)
1.25 in (31.75 mm)

60 Hz

Type
Distributor Kit

Specifications by line voltage

Type
Distributor Kit

Wiring diagram HID H6 – see example on page 180
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
Width (W)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
A
B
Weight
Exit Type
Nominal Length
Frame Size (H x L)

Order information
No. Items Per Standard Package
6

Specifications by lamp and line voltage

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
S62
480
5%
HX-HPF
180C
Dry film
7 Mfd
300
100°C (212°F)
HPS150-3A 86635

Supply Current Frequency

No. Items Per Sales Unit
1

Safety and performance

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics
60 Hz

Order information

Lamp
S68
50W High
Pressure Sodium

1 – 70W HPS S62 480V

General characteristics

Wiring diagram HID W-(H)-87094-87152 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
1.0
B
3.0
Weight
3.40 lbs
Exit Type
Side
Nominal Length
2.7 in (69.85 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Electrical characteristics
Supply Current Frequency

Type
Distributor Kit

High Pressure Sodium

T5
Fluorescent Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

86456 – GES7048TLC3D-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

87152 – GES50MLTLC3D-5

Quick Reference
Guides

gelighting.com

High Pressure Sodium

High Pressure Sodium

For 50 – 150W High Pressure Sodium HID Lamps

For 50 – 150W High Pressure Sodium HID Lamps

High Pressure Sodium
1 – 100W HPS S54 480V

General characteristics

Dimensions

General characteristics

Wiring diagram HID W-(F)-87068-86667 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
3.0
Weight
6.20 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Magnetic – Core and Coil
S55
480
5%
HX-HPF
180C
Dry film
10 Mfd
280
100°C (212°F)
HPS150-3A 86635

Wiring diagram HID W-(E)-87087-86711-86876 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.0
B
4.0
Weight
8.70 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Electrical characteristics

Electrical characteristics

Supply Current Frequency

60 Hz

60 Hz

Order information

Order information
Type
Distributor Kit

No. Items Per Sales Unit
1

Type
Distributor Kit

No. Items Per Standard Package
6

480
135
0.30 A
1
1.11
0.54 A
0.24 A
119V
384V
90
-22 / -30
2
C

cUL Listed

No. Items Per Standard Package
6

250W Quartz
Metal Halide

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

T12
Fluorescent Ballasts

Lamp
S55
150W High
Pressure Sodium

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Sales Unit
1

Specifications by lamp and line voltage

Specifications by lamp and line voltage

Safety and performance

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Magnetic – Core and Coil
S54
480
5%
HX-HPF
180C
Dry film
10 Mfd
280
100°C (212°F)
HPS150-3A

Supply Current Frequency

150W High
Pressure Sodium

High Pressure Sodium
1 – 150W HPS S55 480V

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Lamp
S54
100W High
Pressure Sodium

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

87087 – GES15048TLC3D-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

87068 – GES10048TLC3D-5

Quick Reference
Guides

gelighting.com

480
188
0.40 A
1
1.33
0.73 A
0.31 A
114V
384V
90
-22 / -30
3
F
UL Listed

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

87094 – GES150MLTLC3D-5
High Pressure Sodium
1 – 150W HPS S55 Quad (120/208/240/277V)

General characteristics

Dimensions
Magnetic – Core and Coil
S55
120/208/240/277
10%
HX-HPF
180C
Dry film
14 Mfd
280
100°C (212°F)
HPS150-3A

Wiring diagram HID W-(H)-87094-87152 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.0
B
4.0
Weight
7.60 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Compact Fluorescent
Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
No. Items Per Sales Unit
1

HID Electronic
Ballasts

Type
Distributor Kit

No. Items Per Standard Package
6

Specifications by lamp and line voltage
Lamp
S55
150W High
Pressure Sodium
250W Quartz
Metal Halide

Specifications by line voltage

Safety and performance
164

120
175
1.60 A
1
1.43
2.72 A
1.64 A
115V
96V
90
-22 / -30
10
B
cUL Listed

208
175
0.90 A
1
1.43
1.53 A
0.88 A
115V
166V
90
-22 / -30
5
B

240
175
0.80 A
1
1.43
1.34 A
0.76 A
115V
192V
90
-22 / -30
5
B

277
175
0.70 A
1
1.43
1.16 A
0.65 A
115V
222V
90
-22 / -30
5
B

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

165

HID Electromagnetic
Ballasts

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

High Pressure Sodium

High Pressure Sodium

For 250 – 1000W High Pressure Sodium HID Lamps

For 250 – 1000W High Pressure Sodium HID Lamps

High Pressure Sodium
1 – 250W HPS S50 5-Tap (120/208/240/277/480V)

General characteristics

Dimensions
Magnetic – Core and Coil
S50
120/208/240/277/480
10%
CWA
180C
Oil filled
35 Mfd
240
100°C (212°F)
HPS400-3A

60 Hz

Order information
Type
Distributor Kit

No. Items Per Sales Unit
1

No. Items Per Standard Package
3

Safety and performance

cUL Listed

208
292
1.50 A
1
0.86
1.50 A
0.93 A
186V
166V
90
-22 / -30
5
C

240
292
1.30 A
1
0.86
1.30 A
0.81 A
186V
192V
90
-22 / -30
4
B

277
292
1.10 A
1
0.86
1.10 A
0.70 A
186V
222V
90
-22 / -30
4
B

480
292
0.60 A
1
0.86
0.60 A
0.40 A
186V
384V
90
-22 / -30
4
B

1 – 250W HPS S50 Quad (120/208/240/277V)

General characteristics

Dimensions

No. Items Per Standard Package
3

Specifications by line voltage
120
472
4.00 A
1
0.85
4.00 A
2.87 A
191V
96V
90
-22 / -30
15
C

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise
cUL Listed

208
472
2.20 A
1
0.85
2.20 A
1.66 A
191V
166V
90
-22 / -30
8
C

240
472
2.00 A
1
0.85
2.00 A
1.44 A
191V
192V
90
-22 / -30
8
C

277
472
1.70 A
1
0.85
1.70 A
1.25 A
191V
222V
90
-22 / -30
5
C

480
472
1.00 A
1
0.85
1.00 A
0.72 A
191V
384V
90
-22 / -30
5
C

UL Listed

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

87164 – GES400MLTAC4-5
High Pressure Sodium
1 – 400W HPS S51 Quad (120/208/240/277V)

General characteristics

Wiring diagram HID W-(A)-87056-87121-87164 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
11.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 4.75 in

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
S51
120/208/240/277
10%
CWA
180C
Oil filled
55 Mfd
240
100°C (212°F)
HPS400-3A 86641

Wiring diagram HID W-(A)-87056-87121-87164 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
13.60 lbs
Exit Type
Side
Nominal Length
4.2 in (107.95 mm)
Frame Size (H x L)
4.25 in x 4.75 in

Electrical characteristics

Electrical characteristics

Supply Current Frequency

60 Hz

60 Hz

Order information
No. Items Per Sales Unit
1

Type
Distributor Kit

No. Items Per Standard Package
3

Lamp
S51
400W High
Pressure Sodium

Specifications by line voltage
208
303
1.50 A
1
0.83
1.50 A
0.86 A
186V
166V
90
-22 / -30
5
A

240
303
1.30 A
1
0.83
1.30 A
0.75 A
186V
192V
90
-22 / -30
4
A

277
303
1.10 A
1
0.83
1.10 A
0.63 A
186V
222V
90
-22 / -30
4
A

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

See page 195 for warranty information.

cUL Listed

See page 195 for warranty information.

120
443
3.80 A
1
0.90
3.80 A
1.78 A
186V
96V
90
-22 / -30
15
D

208
443
2.20 A
1
0.90
2.20 A
1.03 A
186V
166V
90
-22 / -30
8
D

240
443
1.90 A
1
0.90
1.90 A
0.90 A
186V
192V
90
-22 / -30
8
D

277
443
1.60 A
1
0.90
1.60 A
0.77 A
186V
222V
90
-22 / -30
5
D

UL Listed

167

HID Electromagnetic
Ballasts

cUL Listed

120
303
2.60 A
1
0.83
2.60 A
1.50 A
186V
96V
90
-22 / -30
8
A

No. Items Per Standard Package
3

Specifications by lamp and line voltage

Specifications by lamp and line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Sales Unit
1

HID Electronic
Ballasts

Order information
Type
Distributor Kit

166

No. Items Per Sales Unit
1

Compact Fluorescent
Ballasts

Magnetic – Core and Coil
S50
120/208/240/277
10%
CWA
180C
Oil filled
35 Mfd
240
100°C (212°F)
HPS400-3A

Supply Current Frequency

Safety and performance

Order information

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

High Pressure Sodium

Lamp
S50
250W High
Pressure Sodium

60 Hz

Type
Distributor Kit

Safety and performance

UL Listed

87121 – GES250MLTAC4-5

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics

Wiring diagram HID W-(B)-87214-87215-87218 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
15.00 lbs
Exit Type
Side
Nominal Length
4.2 in (107.95 mm)
Frame Size (H x L)
4.25 in x 4.75 in
Lead lengths
Orange
Violet and Black
Violet/White
Black/Yellow

T12
Fluorescent Ballasts

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Magnetic – Core and Coil
S51
120/208/240/277/480
10%
CWA
180C
Oil filled
55 Mfd
240
100°C (212°F)
HPS400-3A 86641

Supply Current Frequency

Lamp
S51
400W High
Pressure Sodium

Specifications by line voltage
120
292
2.50 A
1
0.86
2.50 A
1.59 A
186V
96V
90
-22 / -30
8
C

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Specifications by lamp and line voltage

Specifications by lamp and line voltage
Lamp
S50
250W High
Pressure Sodium

1 – 400W HPS S51 5-Tap (120/208/240/277/480V)

General characteristics

Wiring diagram HID W(B)-87214-87215-87218 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.0
B
4.0
Weight
12.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 4.75 in
Lead lengths
Orange
Violet and Black
Violet/White
Black/Yellow

Electrical characteristics
Supply Current Frequency

High Pressure Sodium

T5
Fluorescent Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

87215 – GES400ML5AC4-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

87214 – GES250ML5AC4-5

Quick Reference
Guides

gelighting.com

High Pressure Sodium

High Pressure Sodium

For 250 – 1000W High Pressure Sodium HID Lamps

For 250 – 1000W High Pressure Sodium HID Lamps

High Pressure Sodium
1 – 400W HPS S51 480V in smaller frame

Dimensions

General characteristics

Wiring diagram HID W-(D)-87048-87198-46936 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.25 in (133.35 mm)
Width (W)
1.25 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
2.3
B
4.1
Weight
15.00 lbs
Exit Type
Side
Nominal Length
4.2 in (107.95 mm)
Frame Size (H x L)
4.25 in x 4.75 in

Electrical characteristics

No. Items Per Sales Unit
1

cUL Listed

Specifications by line voltage

High Pressure Sodium
1 – 1000W HPS S52 480V

cUL Listed

208
1,102
5.50 A
1
0.91
5.50 A
3.40 A
435V
166V
90
-22 / -30
15
D

240
1,102
4.70 A
1
0.91
4.70 A
2.90 A
435V
192V
90
-22 / -30
10
D

277
1,102
4.10 A
1
0.91
4.10 A
2.60 A
435V
222V
90
-22 / -30
10
D

UL Listed

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Quad ballast (120, 208, 240, 277)

87056 – GES1000MLTAC5-5
High Pressure Sodium
1 – 1000W HPS S52 Quad (120/208/240/277V)

General characteristics

Dimensions
Magnetic – Core and Coil
S52
480
10%
CWA
180C
Oil filled
26 Mfd
525
100°C (212°F)
HPS24

General characteristics

Wiring diagram HID W-(D)-87048-87198-46936 – see example on page 181
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
7.75 in (196.85 mm)
Width (W)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
3.8
B
6.0
Weight
28.00 lbs
Exit Type
Side
Nominal Length
4.7 in (120.65 mm)
Frame Size (H x L)
4.25 in x 6.00 in

Electrical characteristics

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
S52
120/208/240/277
10%
CWA
180C
Oil filled
26 Mfd
525
100°C (212°F)
HPS1000-4B

Wiring diagram HID W-(A)-87056-87121-87164 – see example on page 181
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
7.75 in (196.85 mm)
Width (W)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
4.0
B
6.0
Weight
28.00 lbs
Exit Type
Side
Nominal Length
4.7 in (120.65 mm)
Frame Size (H x L)
4.25 in x 6.00 in

Compact Fluorescent
Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

480
1,102
2.40 A
1
0.91
2.40 A
1.80 A
435V
384V
90
-22 / -30
8
D

Electrical characteristics

Supply Current Frequency

60 Hz

Supply Current Frequency

Order information

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

120
1,102
9.50 A
1
0.91
9.50 A
5.75 A
435V
96V
90
-22 / -30
20
D

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

87048 – GES100048TAC5-5

60 Hz

Order information
No. Items Per Sales Unit
1

No. Items Per Standard Package
2

Type
Distributor Kit

Specifications by lamp and line voltage

Lamp
S52
1000W High
Pressure Sodium

480
1,129
2.13 A
1
0.89
2.13 A
1.80 A
433V
384V
90
-22 / -30
8
D

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

See page 195 for warranty information.

cUL Listed

See page 195 for warranty information.

120
1,100
9.50 A
1
0.91
9.50 A
5.00 A
430V
96V

208
1,100
5.50 A
1
0.91
5.50 A
3.00 A
430V
166V

240
1,100
4.80 A
1
0.91
4.80 A
2.60 A
430V
192V

277
1,100
4.20 A
1
0.91
4.20 A
2.20 A
430V
222V

-22 / -30
20
A

-22 / -30
15
A

-22 / -30
10
A

-22 / -30
10
A

UL Listed

169

HID Electromagnetic
Ballasts

cUL Listed

No. Items Per Standard Package
2

Specifications by lamp and line voltage

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Sales Unit
1

HID Electronic
Ballasts

Type
Distributor Kit

168

No. Items Per Standard Package
2

T12
Fluorescent Ballasts

480
475
1.00 A
1
0.84
1.00 A
0.60 A
195V
384V
90
-22 / -30
5
D

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

No. Items Per Sales Unit
1

Wiring diagram HID W-(B)-87214-87215-87218 – see example on page 181
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
7.75 in (196.85 mm)
Width (W)
2.75 in (69.85 mm)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
4.0
B
6.0
Weight
28.00 lbs
Exit Type
Side
Nominal Length
4.7 in (120.65 mm)
Frame Size (H x L)
4.25 in x 6.00 in
Lead lengths
Orange
Violet and Black
Violet/White
Black/Yellow

Specifications by lamp and line voltage
Lamp
S52
1000W High
Pressure Sodium

Specifications by line voltage

Safety and performance

60 Hz

Type
Distributor Kit

No. Items Per Standard Package
3

Specifications by lamp and line voltage

Lamp
S52
1000W High
Pressure Sodium

Electrical characteristics
Order information

Order information

Safety and performance

Magnetic – Core and Coil
S52
120/208/240/277/480
10%
CWA
180C
Oil filled
26 Mfd
525
100°C (212°F)
HPS1000-4B

Supply Current Frequency

60 Hz

Type
Distributor Kit

Lamp
S51
400W High
Pressure Sodium

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Magnetic – Core and Coil
S51
480
10%
CWA
180C
Oil filled
55 Mfd
240
100°C (212°F)
HPS400-3A

Supply Current Frequency

High Pressure Sodium
1 – 1000W HPS S52 5-Tap (120/208/240/277/480V)

General characteristics
Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

87218 – GES1000ML5AC5-5

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement

87198 – GES40048TAC4-5

Quick Reference
Guides

gelighting.com

High Intensity Discharge Lamp Ballast Kits
71701 – GEM175ML5AC3-55
1 – 175W MH M57 or H39 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55)

General characteristics

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Type
Distributor Kit

No. Items Per Sales Unit
1

No. Items Per Standard Package
6

Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.3 in (133.35 mm)
Width (W)
1.3 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.3 in (6.35 mm)
A
3.0
B
4.0
Weight
8.00 lbs
Exit Type
Side
Nominal Length
3.2 in (82.55 mm)
Frame Size (H x L)
2.813 in x 3.939 in
Lead Lengths
Orange and Red
Violet and Black
Black/Yellow
Violet/White
Yellow

Safety and performance

cUL Listed

208
202
1.00 A
1
0.87
1.00 A
0.37 A
307V
166V
90
-22 / -30
3
C

240
202
0.90 A
1
0.87
0.90 A
0.32 A
307V
192V
90
-22 / -30
3
C

277
202
0.80 A
1
0.87
0.80 A
0.28 A
307V
222V
90
-22 / -30
2
C

480
202
0.40 A
1
0.87
0.40 A
0.21 A
307V
384V
90
-22 / -30
1.5
C

General characteristics

400W Mercury

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

Dimensions

Electrical characteristics
60 Hz

No. Items Per Standard Package
6

175W Quartz
Metal Halide

Safety and performance
170

cUL Listed

208
436
2.10 A

240
436
1.90 A

277
436
1.60 A

480
436
0.90 A

0.92
3.70 A
2.19 A
300V
96V
90
-22 / -30
10
E

0.92
2.10 A
1.31 A
300V
166V
90
-22 / -30
8
E

0.92
1.90 A
1.11 A
300V
192V
90
-22 / -30
5
E

0.92
1.60 A
1.00 A
300V
222V
90
-22 / -30
5
E

0.92
0.90 A
0.60 A
300V
384V
90
-22 / -30
5
E

cUL Listed

UL Listed

High Intensity Discharge Lamp Ballast Kits
1 – 1000W MH M47 or H36 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55)

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Magnetic – Core and Coil
M47, H36
120/208/240/277/480
10%
CWA
180C
Oil filled
24 Mfd
400
100°C (212°F)

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Type
Distributor Kit

No. Items Per Sales Unit
1

No. Items Per Standard Package
2

Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
7.8 in (196.85 mm)
Width (W)
2.8 in (69.85 mm)
Height (H)
Mounting dimensions
Mount Length (M)
6.1 in (154.94 mm)
Mount Width (X or F)
Mount Slots (MS)
0.3 in (6.35 mm)
A
3.0
B
5.0
Weight
21.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 6.00 in
Lead Lengths
Orange and Red
Violet and Black
Black/Yellow
Violet/White
Yellow

Specifications by lamp and line voltage
208
280
1.40 A
1
0.89
1.60 A
1.00 A
290V
166V
90
-22 / -30
5
B

240
280
1.25 A
1
0.89
1.30 A
0.80 A
290V
192V
90
-22 / -30
4
B

277
280
1.10 A
1
0.89
1.20 A
0.70 A
290V
222V
90
-22 / -30
3
C

480
280
0.65 A
1
0.89
0.70 A
0.50 A
290V
384V
90
-22 / -30
2
C

1000W Mercury

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

See page 195 for warranty information.

cUL Listed

See page 195 for warranty information.

120
1103
9.30 A
1
0.91
9.30 A
6.34 A
445V
96V
90
-22 / -30
20
E

208
1103
5.40 A
1
0.91
5.40 A
3.71 A
445V
166V
90
-22 / -30
15
C

240
1103
4.70 A
1
0.91
4.70 A
3.20 A
445V
192V
90
-22 / -30
10
C

277
1103
4.10 A
1
0.91
4.10 A
2.79 A
445V
222V
90
-22 / -30
10
C

480
1103
2.40 A
1
0.91
2.40 A
1.65 A
445V
384V
90
-22 / -30
10
D

UL Listed

171

HID Electromagnetic
Ballasts

250W Mercury

120
436
3.70 A

71704 – GEM1000ML5AC4-55

Lamp
M47, H33
1000W Quartz
Metal Halide

Specifications by line voltage
120
280
2.50 A
1
0.89
2.60 A
1.50 A
290V
96V
90
-22 / -30
8
B

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

General characteristics

Wiring diagram HID W-(H)-86587-87074 – see example on page 182
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.3 in (133.35 mm)
Width (W)
1.3 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.3 in (6.35 mm)
A
3.0
B
4.3
Weight
9.00 lbs
Exit Type
Side
Nominal Length
3.2 in (82.55 mm)
Frame Size (H x L)
2.813 in x 3.939 in
Lead Lengths
Orange and Red
Violet and Black
Black/Yellow
Violet/White
Yellow

Specifications by lamp and line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Specifications by line voltage

HID Electronic
Ballasts

Order information

Lamp
M58, H37
250W Quartz
Metal Halide

No. Items Per Standard Package
3

Compact Fluorescent
Ballasts

Magnetic – Core and Coil
M58, H37
120/208/240/277/480
10%
CWA
180C
Oil filled
15 Mfd
400
100°C (212°F)

No. Items Per Sales Unit
1

No. Items Per Sales Unit
1

Sign
Ballasts

1 – 250W MH M58 or H37 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55)

Type
Distributor Kit

Order information

Safety and performance

High Intensity Discharge Lamp Ballast Kits

Supply Current Frequency

60 Hz

Type
Distributor Kit

400W Quartz
Metal Halide

UL Listed

71702 – GEM250ML5AC3-55

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics

Wiring diagram HID W-(K)-86808-87210-87211 – see example on page 183
Case dimensions – Ref Drawing PC1 – see page 185
Length (L)
5.3 in (133.35 mm)
Width (W)
1.3 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.3 in (6.35 mm)
A
2.0
B
4.0
Weight
12.50 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 4.75 in
Lead Lengths
Orange and Red
Violet and Black
Black/Yellow
Violet/White
Yellow

T12
Fluorescent Ballasts

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Magnetic – Core and Coil
M59, H33
120/208/240/277/480
10%
CWA
180C
Oil filled
24 Mfd
400
100°C (212°F)

Supply Current Frequency

Lamp
M59, H33
360W Quartz
Metal Halide

Specifications by line voltage
120
202
1.70 A
1
0.87
1.70 A
0.60 A
307V
96V
90
-22 / -30
5
D

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Specifications by lamp and line voltage

Specifications by lamp and line voltage
Lamp
M57, H39, M109

1 – 400W MH M59 or H33 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55)

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

T5
Fluorescent Ballasts

Magnetic – Core and Coil
M57, H38, M109
120/208/240/277/480
10%
CWA
180C
Oil filled
10 Mfd
400
100°C (212°F)

High Intensity Discharge Lamp Ballast Kits
General characteristics

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

71703 – GEM400ML5AC4-55

T8
Fluorescent Ballasts

High Intensity Discharge Lamp Ballast Kits

High Intensity Discharge Lamp Ballast Kits

Quick Reference
Guides

gelighting.com

High Intensity Discharge Lamp Ballast Kits

High Intensity Discharge Lamp Ballast Kits

High Intensity Discharge Lamp Ballast Kits
1 – 100W HPS S54 Quad (120/208/240/277V) Lamp & Ballast Kit (-55)

General characteristics

Dimensions
Magnetic – Core and Coil
S54
120/208/240/277
5%
HX-HPF
180C
Dry Film
10 Mfd
280
100°C (212°F)
HPS100-3A 86884

Magnetic – Core and Coil
S51
120/208/240/277/480
10%
CWA
180C
Oil Filled
55 Mfd
240
100°C (212°F)
HPS1000-4B

Supply Current Frequency

Order information

60 Hz

Order information
No. Items Per Sales Unit
1

No. Items Per Standard Package
6

Type
Distributor Kit

Specifications by lamp and line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise
cUL Listed

No. Items Per Standard Package
3

208
123
1.30 A
1
1.22
1.27 A
0.43 A
119V
166V
90
-22 / -30
5
B

240
123
1.10 A
1
1.22
1.13 A
0.36 A
119V
192V
90
-22 / -30
5
B

Lamp
S51
400W High
Pressure Sodium

277
123
0.90 A
1
1.22
0.94 A
0.31 A
119V
222V
90
-22 / -30
3
B

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

cUL Listed

120
472
4.00 A
1
0.85
4.00 A
2.87 A
191V
96V
90
-22 / -30
15
C

208
472
2.20 A
1
0.85
2.20 A
1.66 A
191V
166V
90
-22 / -30
8
C

240
472
2.00 A
1
0.85
2.00 A
1.44 A
191V
192V
90
-22 / -30
8
C

277
472
1.70 A
1
0.85
1.70 A
1.25 A
191V
222V
90
-22 / -30
5
C

T12
Fluorescent Ballasts

120
123
2.20 A
1
1.22
2.18 A
0.74 A
119V
96V
90
-22 / -30
8
B

No. Items Per Sales Unit
1

Wiring diagram HID W-(B)-87214-87215-87218 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.3 in (133.35 mm)
Width (W)
1.3 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.3 in (6.35 mm)
A
2.0
B
4.0
Weight
15.00 lbs
Exit Type
Side
Nominal Length
4.2 in (107.95 mm)
Frame Size (H x L)
4.25 in x 4.75 in
Lead Lengths
Orange and Red
Violet and Black
Black/Yellow
Violet/White
Yellow

Specifications by lamp and line voltage

Specifications by line voltage

Safety and performance

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Electrical characteristics
60 Hz

Type
Distributor Kit

150W High
Pressure Sodium

1 – 400W HPS S51 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55)

General characteristics

Wiring diagram HID W-(K)-87212-87213 – see example on page 183
Case dimensions – Ref Drawing PC3 – see page 185
Length (L)
5.3 in (133.35 mm)
Width (W)
1.3 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.3 in (6.35 mm)
A
2.0
B
4.0
Weight
6.20 lbs
Exit Type
Side
Nominal Length
2.7 in (68.58 mm)
Frame Size (H x L)
2.813 in x 3.939 in

Electrical characteristics
Supply Current Frequency

Lamp
S54
100W High
Pressure Sodium

High Intensity Discharge Lamp Ballast Kits

T5
Fluorescent Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

71707 – GES400ML5AC4-55

480
472
1.00 A
1
0.85
1.00 A
0.72 A
191V
384V
90
-22 / -30
5
C

UL Listed

Sign
Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

71706 – GES250ML5AC4-55
High Intensity Discharge Lamp Ballast Kits
1 – 250W HPS S50 5-Tap (120/208/240/277/480V) Lamp & Ballast Kit (-55)

General characteristics

Dimensions
Magnetic – Core and Coil
S50
120/208/240/277/480
10%
CWA
180C
Oil Filled
35 Mfd
240
100°C (212°F)
HPS400-3A 86641

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
No. Items Per Sales Unit
1

No. Items Per Standard Package
3

HID Electronic
Ballasts

Type
Distributor Kit

Wiring diagram HID W-(B)-87214-87215-87218 – see example on page 181
Case dimensions – Ref Drawing PC2 – see page 185
Length (L)
5.3 in (133.35 mm)
Width (W)
1.3 in (31.75 mm)
Mounting dimensions
Mount Length (M)
4.6 in (116.84 mm)
Mount Width (X or F)
Mount Slots (MS)
0.3 in (6.35 mm)
A
2.0
B
4.0
Weight
12.00 lbs
Exit Type
Side
Nominal Length
3.7 in (95.25 mm)
Frame Size (H x L)
4.25 in x 4.75 in
Lead Lengths
Orange and Red
Violet and Black
Black/Yellow
Violet/White
Yellow

Compact Fluorescent
Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
GE Igniter
Sound Rating
Additional Info

Specifications by lamp and line voltage
Lamp
S50
250W High
Pressure Sodium

Specifications by line voltage

172

cUL Listed

120
292
2.50 A
1
0.86
2.50 A
1.59 A
186V
96V
90
-22 / -30
8
C

208
292
1.50 A
1
0.86
1.50 A
0.93 A
186V
166V
90
-22 / -30
5
C

240
292
1.30 A
1
0.86
1.30 A
0.81 A
186V
192V
90
-22 / -30
4
B

277
292
1.10 A
1
0.86
1.10 A
0.70 A
186V
222V
90
-22 / -30
4
B

480
292
0.60 A
1
0.86
0.60 A
0.40 A
186V
384V
90
-22 / -30
4
B

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

173

HID Electromagnetic
Ballasts

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

T8
Fluorescent Ballasts

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity
• Distributor replacement kit contains the appropriate core and coil with color coded leads, a properly
rated capacitor and ignitor (if required) and all other components required for ballast replacement
• 5-tap ballast (120, 208, 240, 277, or 480 volt) featuring a 480-volt tap

71705 – GES100MLTLC3D-55

Quick Reference
Guides

gelighting.com

Enclosed and Potted Metal Halide

Enclosed and Potted Metal Halide
• For applications requiring quieter or cooler operation than provided by standard coil and
coil ballasts
• Excellent sound-deadening and heat transfer qualities

86576 – 11210277CTC000C
General characteristics

General characteristics

Dimensions
Magnetic – F-Can
M98, M143

100°C (212°F)
Thermally Protected

Electrical characteristics
60 Hz

Order information
Type
Standard Pack

No. Items Per Sales Unit
1

11.8 in (298.45 mm)
3.2 in (80.96 mm)
2.6 in (66.67 mm)
11.1 in (282.97 mm)
2.0 in (50.80 mm)
0.2 in (5.95 mm)
11.00 lbs
Side
20 ft
18 AWG

Safety and performance

cUL Listed

Type
Standard Pack

100W Quartz
Metal Halide

UL Listed

Wiring diagram HID H34 – see example on page 180
Case dimensions – Ref Drawing FCAN1 – see page 184
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead Lengths
Black and White
Red
Black/Yellow

B (25-30 decibels)
Thermally Protected

60 Hz

Order information

11.8 in (298.45 mm)
3.2 in (80.96 mm)
2.6 in (66.67 mm)
11.1 in (282.97 mm)
2.0 in (50.80 mm)
0.2 in (5.95 mm)
11.00 lbs
Side
20 ft
18 AWG

Magnetic – F-Can
M57, H39
120/277
10%
CWA
90C

Wiring diagram HID H34 – see example on page 180
Case dimensions – Ref Drawing FCAN2 – see page 184
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead Lengths
Black and White
Red
Black/Yellow

100°C (212°F)
B (25-30 decibels)
Thermally Protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Type
Standard Pack

No. Items Per Standard Package
4

No. Items Per Sales Unit
1

14.3 in (363.72 mm)
3.2 in (80.96 mm)
2.6 in (66.67 mm)
13.8 in (349.25 mm)
2.0 in (50.80 mm)
0.2 in (5.84 mm)
14.00 lbs
Side

No. Items Per Standard Package
2

Specifications by lamp and line voltage
Lamp
M57, H39
175W Ceramic
Metal Halide

Specifications by line voltage
120
90
0.78 A
1
0.78
2.00 A
0.60 A
250V
96V
90
-22 / -30
6

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Sound Rating
Additional Info

277
90
0.35 A
1
0.78
0.90 A
0.27 A
250V
222V
90
-22 / -30
3

150W Quartz
Metal Halide
175W Mercury

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

See page 195 for warranty information.

cUL Listed

See page 195 for warranty information.

120
205
1.75 a
1
0.85

277
205
0.75 A
1
0.85

300V
96V
90
-22 / -30
5

300V
222V
90
-22 / -30
3

UL Listed

175

HID Electromagnetic
Ballasts

174

Enclosed and Potted Metal Halide
General characteristics

Specifications by lamp and line voltage

cUL Listed

• For applications requiring quieter or cooler operation than provided by standard coil and
coil ballasts
• Excellent sound-deadening and heat transfer qualities

86563 – 1110245SCTC000I

HID Electronic
Ballasts

No. Items Per Sales Unit
1

Safety and performance

UL Listed

Compact Fluorescent
Ballasts

Magnetic – F-Can
M98
120/277
5%
HX-HPF
90C

Electrical characteristics

70W Quartz
Metal Halide

cUL Listed

277
125
1.10 A
1
0.80
1.10 A
0.50 A
250V
222V
90
-22 / -30
4

1 – 175W M57 120/277 Enclosed and Potted

Dimensions

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

120
125
2.20 A
1
0.80
2.20 A
1.10 A
250V
96V
90
-22 / -30
8

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Sign
Ballasts

• For applications requiring quieter or cooler operation than provided by standard coil and
coil ballasts
• Excellent sound-deadening and heat transfer qualities

General characteristics

Lamp
M98
70W Ceramic
Metal Halide

No. Items Per Standard Package
4

Specifications by line voltage

Safety and performance

1 – 70W M98 120/277 Enclosed and Potted

Type
Standard Pack

No. Items Per Sales Unit
1

11.1 in (282.97 mm)
2.0 in (50.80 mm)
0.2 in (5.95 mm)
11.00 lbs
Side
20 ft
18 AWG

Specifications by lamp and line voltage
Lamp
M90
100W Ceramic
Metal Halide

277
90
0.35 A
1
0.78
0.90 A
0.27 A
250V
222V
90
-22 / -30
3

Enclosed and Potted Metal Halide

Supply Current Frequency

60 Hz

Order information

No. Items Per Standard Package
4

86578 – 11210506CTC000C

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Sound Rating
Additional Info

100°C (212°F)
B (25-30 decibels)
Thermally Protected

11.8 in (298.45 mm)
3.2 in (80.96 mm)
2.6 in (66.67 mm)

T12
Fluorescent Ballasts

70W Quartz
Metal Halide

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Wiring diagram HID H34 – see example on page 180
Case dimensions – Ref Drawing FCAN1 – see page 184
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead Lengths
Black and White
Red
Black/Yellow

Electrical characteristics

Specifications by line voltage
120
90
0.78 A
1
0.78
2.00 A
0.60 A
250V
66V
90
-22 / -30
6

Magnetic – F-Can
M90
120/277
5%
HX-HPF
90C

Supply Current Frequency

Specifications by lamp and line voltage
Lamp
M98, M143
70W Ceramic
Metal Halide

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Wiring diagram HID H34 – see example on page 180
Case dimensions – Ref Drawing FCAN1 – see page 184
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead Lengths
Black and White
Red
Black/Yellow

5%
HX-HPF
90C

Supply Current Frequency

Enclosed and Potted Metal Halide
1 – 100W M90 120/277 Enclosed and Potted

1 – 70W M85 120/277 Enclosed and Potted
Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Sound Rating
Additional Info

• For applications requiring quieter or cooler operation than provided by standard coil and
coil ballasts
• Excellent sound-deadening and heat transfer qualities

86574 – 11210239CTC000I

T8
Fluorescent Ballasts

Enclosed and Potted Metal Halide

Quick Reference
Guides

gelighting.com

Enclosed and Potted Metal Halide

Enclosed and Potted Metal Halide
• For applications requiring quieter or cooler operation than provided by standard coil and
coil ballasts
• Excellent sound-deadening and heat transfer qualities

86564 – 1110246CTC000C
1 – 250W M58 120/277 Enclosed and Potted
Magnetic – F-Can
M58, H37
120/277
10%
CWA
90C

Electrical characteristics
60 Hz

Order information
Type
Standard Pack

No. Items Per Sales Unit
1

General characteristics
16.8 in (425.45 mm)
3.2 in (81.02 mm)
2.7 in (69.59 mm)
16.1 in (409.57 mm)
2.0 in (50.80 mm)
0.2 in (5.94 mm)
17.50 lbs
Side

250W Mercury

Safety and performance

60 Hz

Order information

No. Items Per Standard Package
2

Type
Standard Pack

No. Items Per Sales Unit
1

13.8 in (349.25 mm)
2.0 in (50.80 mm)
0.2 in (5.84 mm)
14.00 lbs
Side

No. Items Per Standard Package
4

Specifications by lamp and line voltage

120
295
2.50 A
1
0.85

277
295
1.10 A
1
0.85

280V
96V
90
-22 / -30
8

280V
222V
90
-22 / -30
4

Lamp
M59, H33
360W Quartz
Metal Halide
400W Quartz
Metal Halide
400W Mercury

cUL Listed

100°C (212°F)
C (31-36 decibels)
Thermally Protected

14.3 in (363.72 mm)
3.2 in (80.96 mm)
2.6 in (66.67 mm)

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Safety and performance

UL Listed

cUL Listed

120
460
3.90 A
1
0.87

277
460
1.70 A
1
0.87

300V
96V

300V
222V

-22 / -30
10

-22 / -30
5

T12
Fluorescent Ballasts

175W Quartz
Metal Halide

Wiring diagram HID H36 – see example on page 180
Case dimensions – Ref Drawing FCAN2 – see page 184
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead Lengths
Black and White
Red
Black/Yellow

Electrical characteristics

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Magnetic – F-Can
M59, H33
120/277
10%
CWA
90C

Supply Current Frequency

Specifications by lamp and line voltage
Lamp
M58, H37
250W Quartz
Metal Halide

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Wiring diagram HID H34 – see example on page 180
Case dimensions – Ref Drawing FCAN3 – see page 184
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead Lengths
Black and White
Red
Black/Yellow

100°C (212°F)
C (31-36 decibels)
Thermally Protected

Supply Current Frequency

Enclosed and Potted Metal Halide
1 – 400W M59 120/277 Enclosed and Potted

Dimensions

General characteristics
Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Sound Rating
Additional Info

• For applications requiring quieter or cooler operation than provided by standard coil and
coil ballasts
• Excellent sound-deadening and heat transfer qualities

80728 – 1111-247SCTC000I

T8
Fluorescent Ballasts

Enclosed and Potted Metal Halide

UL Listed

Sign
Ballasts

• For applications requiring quieter or cooler operation than provided by standard coil and
coil ballasts
• Excellent sound-deadening and heat transfer qualities

42670 – 1110-247SC-TC
Enclosed and Potted Metal Halide

Quick Reference
Guides

gelighting.com

1 – 400W M59 120/277 Enclosed and Potted F-Can

General characteristics

Dimensions
Magnetic – F-Can
M59, H33
120/277
10%
CWA
90C

Wiring diagram HID H34 – see example on page 180
Case dimensions – Ref Drawing FCAN4 – see page 184
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead Lengths
Black and White
Red
Black/Yellow

100°C (212°F)
C (31-36 decibels)
Thermally Protected

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
No. Items Per Sales Unit
1

18.6 in (473.07 mm)
2.0 in (50.80 mm)
0.2 in (5.95 mm)
23.00 lbs
Side

No. Items Per Standard Package
2

HID Electronic
Ballasts

Type
Standard Pack

19.3 in (488.95 mm)
3.2 in (80.96 mm)
2.6 in (66.67 mm)

Compact Fluorescent
Ballasts

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Sound Rating
Additional Info

Specifications by lamp and line voltage
Lamp
M59, H39
360W Quartz
Metal Halide
400W Quartz
Metal Halide
400W Mercury

Specifications by line voltage

Safety and performance
176

cUL Listed

120
455
3.90 A
1
0.88
3.90 A
2.50 A
300V
66V
90
-22 / -30
10
C

277
455
1.70 A
1
0.88
1.70 A
1.00 A
300V
222V
90
-22 / -30
5
C
UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

177

HID Electromagnetic
Ballasts

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

F-Can and Post Mount High Pressure Sodium

F-Can and Post Mount High Pressure Sodium

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity

86605 – 1233142U000I

• Magnetic ballast construction ideal for a wide variety of lighting applications
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity

86606 – 1233154U000I
F-Can and Post Mount High Pressure Sodium

1 – 70W S62 120 Reactor-NPF

1 – 150W S55 120 Reactor-NPF

General characteristics

Dimensions
Magnetic – Core and Coil
S62
120
5%
R-HPF
R-NPF
90C

100°C (212°F)

Electrical characteristics
Supply Current Frequency

60 Hz

Order information
Type
Standard Pack

No. Items Per Sales Unit
1

No. Items Per Standard Package
6

120
83
0.75 A
1
0.84
1.30 A
0.90 A
120V
96V
90
-22 / -30
5
A

Electrical characteristics

120
83
1.60 A
1
0.84
2.10 A
2.10 A
120V
96V
80
-22 / -30
8
A

Type
Standard Pack

No. Items Per Sales Unit
1

250W Quartz
Metal Halide

0.25 in (6.35 mm)
2.0
3.0
3.50 lbs
Side
2.813 in x 3.939 in

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

120
171
1.50 A
1
1.46
2.40 A
2.20 A
120V
96V
90
-22 / -30
8
A

cUL Listed

120
171
3.20 A
1
1.46
4.40 A
4.40 A
120V
96V
80
-22 / -30
15
A
UL Listed

General characteristics

Dimensions

100°C (212°F)
Thermally protected

Electrical characteristics
60 Hz

Order information
No. Items Per Standard Package
4

11.75 in (298.45 mm)
3.188 in (80.96 mm)
2.625 in (66.67 mm)
11.14 in (282.97 mm)
2.00 in (50.80 mm)
0.23 in (5.95 mm)

Replacement Ignitors for Pulse
Start Lamps (MH & HPS)

11.00 lbs
Side

Other Accessories

Description
005-1184-MF
005-1185-MF
005-1422-MF
005-2779-MF
005-3160-MF
MH100-3A
HPS150-3A
HPS400-3A
000-8724
001-2009
004-9177
2BMB1000C

Application
10.0 MFD 400V 90C 2.4 MEG 1.50 oval 2.7 ht
15.0 MFD 400V 90C 1.6 MEG 1.75 oval 2.7 ht
48.0 MFD 300V 90C 0.6 MEG 1.75 oval 3.9 ht
24.0 MFD 480V 90C 1.75 oval 3.9 ht
24.0 MFD 360V 90C 1.0 MEG 1.75 oval 3.1 ht
Ignitor for MH 30 50 70 100
Ignitor HPS 150 watts or less except 150w-S56
Ignitor HPS 200-400 watts & 150w S56
HIDP Adjustable Mounting Bracket Hardware Kit
Splice Box
Adjustable Mounting Bracket For 4” HID
HID Parts E&P Mounting Bracket

Units Per Carton
20
20
20
20
20
20
20
10
100
10
50
50

HID Electronic
Ballasts

No. Items Per Sales Unit
1

Wiring diagram HID H34 – see example on page 180
Case dimensions – Ref Drawing FCAN1 – see page 184
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
A
B
Weight
Exit Type
Nominal Length
Frame Size (H x L)
Lead lengths
White
Black
Black/Yellow
Red

Prod Code
88980
88982
89007
89077
89083
86864
86635
86641
47621
86467
86468
86624

Compact Fluorescent
Ballasts

Magnetic – F-Can
S62
120/277
5%
HX-HPF
90C

HID Accessories
HID Accessories
Replacement Capacitors

1 – 70W S62 120/277 E & P F-Can built-in starter

Type
Standard Pack

4.00 in (101.60 mm)
3.30 in (85.09 mm)

Sign
Ballasts

• For applications requiring quieter or cooler operation than provided by standard coil & coil ballasts
• Excellent sound-deadening and heat transfer qualities

F-Can and Post Mount High Pressure Sodium

Supply Current Frequency

No. Items Per Standard Package
6

4.00 in (101.60 mm)
0.75 in (19.05 mm)
0.00 in (2.36 mm)

UL Listed

86596 – 12210237CTC000I

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Sound Rating
Additional Info

60 Hz

Order information

Safety and performance
cUL Listed

Thermally protected

Wiring diagram HID H1 – see example on page 180
Case dimensions – Ref Drawing 1 – see page 184
Length (L)
Width (W)
Height (H)
Mounting dimensions
Bracket Length (BL)
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
A
B
Weight
Exit Type
Nominal Length
Frame Size (H x L)
Lead lengths
Black
Blue
White

T12
Fluorescent Ballasts

Safety and performance

52 Mfd
120
100°C (212°F)

Supply Current Frequency

Lamp
S55
150W High
Pressure Sodium

Specifications by line voltage
System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Magnetic – Core and Coil
S55
120
5%
R-NPF
180C

Specifications by lamp & line voltage

Specifications by lamp & line voltage
Lamp
S62
70W High
Pressure Sodium

Dimensions

Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)
Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Sound Rating
Additional Info

T5
Fluorescent Ballasts

Circuit Type
Insulation Class
Type of Capacitor
Capacitance
Voltage (MIN)
Capacitor Temperature Rating
Sound Rating
Additional Info

General characteristics

Wiring diagram HID H1a, HID H1 – see example on page 180
Case dimensions – Ref Drawing 1 – see page 184
Length (L)
4.00 in (101.60 mm)
Width (W)
0.75 in (19.05 mm)
Height (H)
0.00 in (2.36 mm)
Mounting dimensions
Bracket Length (BL)
4.00 in (101.60 mm)
Mount Length (M)
3.30 in (85.09 mm)
Mount Width (X or F)
Mount Slots (MS)
0.25 in (6.35 mm)
A
1.3
B
2.6
Weight
2.50 lbs
Exit Type
Side
Nominal Length
Frame Size (H x L)
Lead lengths
Black
Blue
White

T8
Fluorescent Ballasts

F-Can and Post Mount High Pressure Sodium
Ballast Type
ANSI Lamp Codes
Voltage
Line Voltage Regulation (+/-)

Specifications by lamp & line voltage
Lamp
S62
70W High
Pressure Sodium

Specifications by line voltage

Safety and performance
178

120
98
0.87 A
1
0.71
0.87 A
0.60 A
140V
96V
90
-22 / -30
6

cUL Listed

277
98
0.39 A
1
0.71
0.39 A
0.27 A
140V
222V
90
-22 / -30
3

UL Listed

See page 195 for warranty information.

See page 195 for warranty information.

179

HID Electromagnetic
Ballasts

System Wattage (W)
Nominal Current
Ballast Factor
Ballast Efficiency Factor
Max Input Current
Starting Current
Open Circuit Voltage
Drop Out Voltage
Power Factor (>=)%
Min. Starting Temp (°F/°C)
Fuse Rating
UL Bench Top Rise

Quick Reference
Guides

gelighting.com

Wiring Diagrams
HID Electromagnetic Ballasts
HID H1

Wiring Diagrams
HID Electromagnetic Ballasts
HID H1a

HID W-(A)-86959-86984-87008

HID W-(A)-87056-87121-87164

HID W-(B)-87214-87215-87218

HID W-(C)-86655-86698-86741

HID W-(C)-86765-86814

HID W-(D)-86952-86999

HID W-(D)-87048-87198-46936

T8
Fluorescent Ballasts

HID W-(A)-46934-86885-86935

Quick Reference
Guides

gelighting.com

Sign
Ballasts
Compact Fluorescent
Ballasts

HID H21

See page 195 for warranty information.

181

HID Electromagnetic
Ballasts

See page 195 for warranty information.

HID Electronic
Ballasts

180

HID H36

T12
Fluorescent Ballasts

HID H6

T5
Fluorescent Ballasts

HID H34

Wiring Diagrams
HID Electromagnetic Ballasts

Wiring Diagrams
HID Electromagnetic Ballasts
HID W-(E)-87087-86711-86876

HID W-(F)-87068-86667

HID W-(H)-86587-87074

HID W-(K)-86808-87210-87211

HID W-(K)-87212-87213
T8
Fluorescent Ballasts

HID W-(E)-86926

Quick Reference
Guides

gelighting.com

T5
Fluorescent Ballasts

HID W-(L)-86968

T12
Fluorescent Ballasts

HID W-(H)-86824-86847

HID W-(H)-87094-87152

HID W-(J)-86650-86693-86803

Sign
Ballasts

HID W-(H)-86675-86718

Compact Fluorescent
Ballasts
HID Electronic
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

183

HID Electromagnetic
Ballasts

182

Case Dimensions
HID Electromagnetic Ballasts
1

Case Dimensions
HID Electromagnetic Ballasts
FCAN1

PC1

Quick Reference
Guides

gelighting.com

PC2
T8
Fluorescent Ballasts

A

T5
Fluorescent Ballasts
T12
Fluorescent Ballasts

FCAN2

FCAN3
PC3

Sign
Ballasts
Compact Fluorescent
Ballasts

FCAN4

HID Electronic
Ballasts

See page 195 for warranty information.

See page 195 for warranty information.

185

HID Electromagnetic
Ballasts

184

Glossary

HID Electromagnetic
Ballasts

187

HID Electronic
Ballasts

High-Pressure Sodium (HPS) Lamp
HPS lamps are high intensity discharge light
sources that produce light by an electrical
discharge though sodium vapor operating at
relatively high pressures and temperatures. GE
trade name is Lucalox®.
Hot Restart Time
Time it takes for an HID lamp to reach 90% of light
output after going from on to off to on.
Ignitor
An electronic device providing a high voltage pulse
to initiate an electrical discharge. Typically, the
ignitor is paired with or is a part of the ballast
(see STARTER).
Infrared Radiation
Electromagnetic energy radiated in the
wavelength range of about 770 to 1,000,000
nanometers. Energy in this range cannot be seen
by the human eye, but can be sensed as heat.
Input Voltage
Power supply voltage required for proper operation
of fluorescent or HID ballast.

Input Watts
The total power input to the ballast that includes
lamp watts and ballast losses. The total power
input to the fixture is the input watts to the ballast
or ballasts and is the value to be used when
calculating cost of energy. More than 90% of the
input watts is wattage or power delivered to the
lamp load with typical ballast.
Instant Start
Lamp starting method in which lamps are started
by high voltage input with no preheating of lamp
filaments. Some rapid start lamps are designed so
that they may be instant started.
Instant Start Lamp
A fluorescent lamp, usually with a single pin at each
end, approved to operate on instant start ballasts.
The lamp is ignited by a high voltage without any
filament heating.
Integral
A popular term for a compact fluorescent lamp
that includes a built-in ballast (see CFL).
Kilowatt (kW)
The measure of electrical power equal to 1000
watts.
Kilowatt Hour (kWh)
The standard measure of electrical energy and
the typical billing unit used by electrical utilities for
electricity use. A 100-watt lamp operated for 10
hours consumes 1000 watt-hours (100 x 10) or one
kilowatt-hour. If the utility charges $.10/kWh, then
the electricity cost for the 10 hours of operation
would be 10 cents (1 kWh x $.10).
Laminations
Layers of steel, making up the “core” that is
surrounded by the coils in a core and coil ballast.
Lamp
The term used to refer to the complete light-source
package, including the inner parts as well as
the outer bulb or tube. “Lamp,” of course, is also
commonly used to refer to a type of small light
fixture such as a table lamp.
Lamp Types
Filament lamps: Incandescent, Halogen, Halogen-IR.
Discharge Lamps: Fluorescent, HID (High Intensity
Discharge).
HID Lamps: Mercury, HPS (High Pressure Sodium),
MH (Metal Halide) and Ceramic Metal Halide.
Lamp Watts
Input power used to operate lamps.
Life
(See RATED LAMP LIFE.)
Light
Radiant energy that can be sensed or seen by the
human eye. Visible light is measured in lumens.
Light-Emitting Diode (LED)
A solid that directly converts electrical impulses
into light.
Light Loss Factor
The product of all factors that contribute to
lowering the illumination level including reflector
degradation, dirt, lamp depreciation over time,
voltage fluctuations, etc.
Lumens
A measure of the luminous flux or quantity of light
emitted by a source. For example, a dinner candle
provides about 12 lumens. A 60-watt Soft White
incandescent lamp provides about 840 lumens.

Compact Fluorescent
Ballasts

Fluorescent Lamp
A high efficiency lamp utilizing an electric
discharge through inert gas and low-pressure
mercury vapor to produce ultraviolet (UV) energy.
The UV excites phosphor materials applied as a
thin layer on the inside of a glass tube that makes
up the structure of the lamp. The phosphors
transform the UV to visible light.
Footcandles
A unit of illuminance or light falling onto a surface.
It stands for the light level on a surface one foot
from a standard candle. One footcandle is equal to
one lumen per square foot.
Four-Pin Compact Fluorescent Lamps
A “plug-in” compact fluorescent lamp with four
pins in the base to make electrical contact.
Frequency
Rate of alternation in an AC current. Expressed in
cycles per second or Hertz (Hz).
Harmonic
An integral multiple of the fundamental frequency
(60 Hz) that becomes a component of the current.
Harmonic Distortion
Distortion of an AC waveform caused by multiples
of the fundamental frequency (harmonics). Odd
triplet harmonics (thirds, ninths, etc.) may result in
large currents on the neutral line in a four-wire Wye
three-phase system.
Hertz (Hz)
Unit used to measure frequency of alteration of
current or voltage.
High Efficiency (Energy-Saving) Electromagnetic
Ballast
Ballast with core and coils, designed to minimize
ballast losses compared to the “standard” ballast.
High Intensity Discharge (HID) Lamp
A general term for mercury, metal halide (GE
ConstantColor® CMH®, Multi-Vapor®, MXR or
Arcstream®) and high-pressure sodium (GE
Lucalox®) lamps. HID lamps contain compact arc
tubes which enclose mercury and various gases
with other chemicals and operate at relatively high
pressures and temperatures.
High Power Factor
A ballast whose power factor is corrected to 90%
or greater.

Sign
Ballasts

a 100-watt incandescent lamp converts 7% of
the electrical energy into light; discharge lamps
convert 25% to 40% into light.
Efficiency of Ballast
The ratio of output power divided by input power.
A premium ballast would have an electrical
efficiency greater than 90%. The efficiency of a
luminaire or fixture is the percentage of the lamp
lumens that actually come out of the fixture.
Electrical Discharge
A condition under which a gas becomes electrically
conducive and becomes capable of transmitting
current, usually accompanied by the emission of
visible and other radiation. An electric spark in air
is an example of an electrical discharge, as are a
welder’s arc and a lightning bolt.
Electrical Testing Laboratory (ETL)
Independent testing laboratory that performs tests
and certifies performance data.
Electrode
Any metal terminal emitting or collecting
charged particles, typically inside the chamber
of a gas discharge lamp. In a fluorescent lamp,
the electrodes are typically metal filaments
coated with special powders called emission mix.
Negatively charged free electrons emitted by one
electrode are attracted to the positive electrode
(anode), creating an electric current arc.
Electromagnetic Ballast (Magnetic Ballast)
A ballast used with discharge lamps that consists
primarily of transformer-like copper or aluminum
windings on a steel or iron core. Also called “core
and coil” (see ELECTRONIC BALLASTS).
EMI (Electromagnetic Inference)
High-frequency electronic ballasts and other
electronic devices can produce a small amount
of radio waves which can interfere with radio
and TV. Federally mandated requirements must
be met for EMI levels before an electronic device
is considered FCC compliant (FCC is the Federal
Communications Commission).
Electronic Ballast
A short name for a fluorescent high-frequency
electronic ballast. Electronic ballasts use solidstate electronic components and typically operate
fluorescent lamps at frequencies greater than 25
kHz. The benefits are: increased lamp efficacy,
reduced ballast losses and lighter, smaller ballasts
compared to electromagnetic ballasts. Electronic
ballasts may also be used with HID (high intensity
discharge) lamps (see ELECTROMAGNETIC BALLAST).
Energy Policy Act (EPACT)
U.S. Energy legislation setting minimum efficacy
(lumens/watt) requirements. Federal Canadian
legislation sets similar requirements.
Federal Communications Commission (FCC)
The U. S. federal agency that regulates emissions in
the radio frequency portion of the electromagnetic
spectrum. Part 18 of the FCC rules specifies
electromagnetic interference (EMI) from lighting
devices at frequencies greater than 450 kilohertz
(kHz). A consumer-rated Class B ballast is designed
for use in the home near TV and radio receivers. It
produces less electrical noise that could interfere
with consumer products. A Class A-rated ballast
is designed for use in commercial and industrial
applications that are not in the vicinity of TV and
radio receivers.
Flicker
The periodic variation in light level caused by AC
operation that can lead to strobe effects.

T12
Fluorescent Ballasts

Color Rendering Index (CRI)
An international system used to rate a lamp’s
ability to render object colors. The higher the
CRI (based upon a 0-100 scale) the richer colors
generally appear.
Color Temperature (Correlated Color
Temperature – CCT)
A number indicating the degree of “yellowness”
or “blueness” of a white light source. Measured
in kelvins, CCT represents the temperature an
incandescent object (like a filament) must reach
to mimic the color of the lamp. Yellowish-white
(“warm”) sources, like incandescent lamps, have
lower color temperatures in the 2700K-3000K
range; white and bluish-white (“cool”) sources, such
as cool white (4100K) and natural daylight (6000K),
have higher color temperatures. The higher the
color temperature, the bluer the light will be.
Compact Fluorescent Lamp (CFL)
The general term applied to fluorescent lamps that
are single-ended and that have smaller diameter
tubes that are bent to form a compact shape.
Some CFLs have integral ballasts and medium or
candelabra screw bases for easy replacement of
incandescent lamps.
Cool White
A term loosely used to denote a color temperature
of around 4100K. The Cool White (CW) designation
is used specifically for T12 and other fluorescent
lamps using halophosphors and having a CRI of 62.
Core
Component of electromagnetic ballast that is
surrounded by the coil. Core is comprised of steel
laminations or solid ferrite material.
Core & Coil Ballast
A ballast that uses a “Core & Coil” assembly to
operate fluorescent or HID lamps. Refers to copper
or aluminum windings on a steel core.
Cost of Light
Usually refers to the cost of operating and
maintaining a lighting system on an ongoing basis.
The 88-8-4 rule states that (typically) 88% is the
cost of electricity, 8% is labor and only 4% is the
cost of lamps.
Crest Factor (Lamp Current Crest Factor)
Ratio of peak to RMS for any AC waveform. Crest
factor can refer to voltage crest factor or current
crest factor.
Daylight Harvesting
Lighting design for building interiors that makes
use of daylight as a way of reducing energy
consumption.
Dimmer, Dimming Control
A device used to lower the light output of a
source, usually by reducing the wattage it is being
operated at. Dimming controls are increasing in
popularity as energy-conserving devices.
Ecolux®
A term for GE lamps that have reduced mercury
content and pass the TCLP test.
Efficacy
A measurement of how effective the light source is
in converting electrical energy to lumens of visible
light. Expressed in lumens-per-watt (LPW), this
measure gives more weight to the yellow region
of the spectrum and less weight to the blue and
red regions where the eye is not as sensitive. The
efficiency of a light source is simply the fraction
of electrical energy converted to light, i.e. watts of
visible light produced for each watt of electrical
power with no concern about the wavelength
where the energy is being radiated. For example,

T5
Fluorescent Ballasts

Bottom Exit (BE)
(CFL plug-in ballasts) A configuration with leads or
a wire-trap on the bottom or base of the ballast.
This type of configuration is usually used when the
ballast is mounted onto a junction box plate.
Bottom Exit Studs (BES)
(CFL plug-in ballasts) A configuration with screw
studs mounted on the base plate or bottom of the
ballast. The screws are 3/8-inch long with a #8-32
thread size (#8-32 nut). They are mounted on a
2-inch center. The studs are usually used to mount
the ballast directly onto a junction box plate.
Bulb Size
Bulb shape followed by its size (the maximum
diameter of the bulb expressed in eighths of an
inch). For Compact Fluorescent products, “S”, “D”,
“T”, and “Q” are used to represent Single, Double,
Triple and Quad Biax® sizes. The code also includes
a reference such as T4 to represent the size of the
tube. Rectangular headlamps are designated as
“Rect” and the number of millimeters horizontally.
Canadian Energy Standards
Indicates ballast complies with Canadian Energy
Standards and meets the requirements of CAN/
CSA C654-M91.
Canadian Standards Associations (CSA)
Association that generates product
performance and safety standards for
many Canadian industries.
Capacitor
Device in ballast that stores electrical energy,
and is used for power factor correction and
lamp regulation.
Cathode
Metal filaments that emit electrons in a fluorescent
lamp. Negatively charged free electrons emitted
by the cathode are attracted to them, creating an
electric current between the electrodes.
Cathode Resistance
Resistance of the cathode in a Fluorescent lamp. It
is measured “cold” before the lamp is turned on (Rc)
or “hot” after the lamp is turned on (Rh). The ratio
of the hot resistance to the cold resistance is also
measured (Rh/Rc).
Ceramic Metal Halide
A type of metal halide lamp that uses a ceramic
material for the arc tube instead of glass quartz,
resulting in better color rendering (>80 CRI) and
improved lumen maintenance. GE ConstantColor®
CMH® lamps deliver reliability and excellent color.
ChromaFit
A GE brand name for metal halide lamps designed
to operate on HPS ballasts, allowing a user to
switch from the yellowish color of HPS to the white
color of metal halide without changing ballasts.
These products are available in both quartz metal
halide and ceramic metal halide (CMH) versions.
Class P Thermal Protector
A switching device sensitive to current and heat
that automatically disconnects ballast if the
temperature exceeds UL temperature limitations.
Coefficient of Utilization (CU)
In general lighting calculations, the fraction of
initial lamp lumens that reach the work plane. CU
is a function of luminaire efficiency, room surface
reflectances and room shape.
Coil
Windings of copper or aluminum wire surrounding
the steel core in ballast. Also refers to the entire
assembly comprising the inductor or transformer.

T8
Fluorescent Ballasts

Amperes
(“Amps.”) A measure of electrical current. The
current is related to voltage and power as follows:
Watts (power) = Volts x Amps (current).
ANSI (American National Standards Institute)
A consensus-based organization which
coordinates voluntary standards for the physical,
electrical and performance characteristics of
lamps, ballasts, luminaires and other lighting and
electrical equipment.
ANSI Ballast Type
Ballast type used to operate lamp in accordance
with ANSI standard.
ANSI Codes
These are 3-letter codes assigned by the American
National Standards Institute. They provide a
system of assuring mechanical and electrical
interchangeability among similarly coded lamps
from various manufacturers. General Electric uses
the assigned ANSI Codes as Lamp Ordering Codes
for most Projection Lamps.
Auto Reset Shutdown Circuit
Circuit senses lamp end life and will automatically
shut off power to the lamp(s). When a new lamp is
inserted in the socket, the ballast resets, and turns
on the lamp automatically. Some shutdown circuits
require the power to be cycled before a new lamp
will re-light.
Ballast
An auxiliary piece of equipment required to start
and to properly control the flow of current to gas
discharge light sources such as fluorescent and
high intensity discharge (HID) lamps. Typically,
magnetic ballasts (also called electromagnetic
ballasts) contain copper windings on an iron core
while electronic ballasts are smaller and more
efficient and contain electronic components.
Ballast Efficacy Factor (BEF)
Defined as ballast factor x100 divided by input
watts. The value is used to evaluate various lighting
systems based on light output and power input.
The BEF can only be used to compare systems
operating the same type and quantity of lamps.
Ballast Factor (BF)
This is the percentage of a lamp’s rated lumen
output that can be expected when operated on a
specific, commercially available ballast. Note that
the “rated output” is sometimes measured on a
reference ballast unlike ones that actually operate
the lamp in the field. For example, a ballast with
a ballast factor of 0.93 will result in the lamp’s
emitting 93% of its rated lumen output. A ballast
with a lower BF results in less light output and also
generally consumes less power.
Ballast Hum
Sound generated by the vibration of laminations in
the iron core or inductor in the ballast.
Ballast Losses
Power or energy dissipated in the ballast as heat
and not converted to lamp energy.
Base Temperature (Maximum)
The maximum operating temperature permitted
for the base in Celsius. Fixture manufacturers need
to ensure that these conditions are satisfied.
Bi-Pin
Any base with two metal pins for electrical contact.
This is the typical base for a fluorescent tube of 1 to
4 feet in length. It consists of 2 prong contacts that
connect into the fixture. Medium bi-pins are used
with type T-8 and T-12 tubular fluorescent lamps,
and miniature bi-pins are used for tubular T-5
fluorescent lamps.
186

Quick Reference
Guides

gelighting.com

Glossary (cont.)

HID Electromagnetic
Ballasts

189

HID Electronic
Ballasts

HID ballast which can operate PulseArc® and CMH®
lamps anywhere from 250 watts to 400 watts and
provides greatly improved lumen maintenance.
UltraStart® Ballast
A family of high-efficiency GE programmed start
electronic linear fluorescent ballasts designed to
optimize GE’s T8 Ultra lamps in frequently switched
applications. Instant start ballast provides 10,000
starts. UltraStart® provides 100,000 to 200,000
starts. Use programmed start ballast to ensure
long lamp life when turning lamps on and off more
than twice a day.
Ultraviolet (UV) Radiation
Radiant energy in the range of about 100-380
nanometers (nm). For practical applications, the UV
band is broken down.
The International Commission on Illumination (CIE)
defines the UV band as UV-A (315-400 nm); UV-B
(280-315 nm) and UV-C (100-280 mm).
Ultra Watt-Miser®
GE’s family of energy-saving T8 fluorescent lamps.
Veiling Reflection
Reflected glare from a light source bouncing off a
shiny surface.
Visual Comfort Probability (VCP)
VCP is the percent of people who find the lighting
scheme acceptable in terms of glare.
Volt
A measure of “electrical pressure” between two
points. The higher the voltage, the more current
will be pushed through a resistor connected across
the points. The volt specification is the electrical
“pressure” required to drive it at its designated
point. The “voltage” of a ballast (e.g. 277 V) refers
to the line voltage it must be connected to.
Voltage
A measurement of the electromotive force in
an electrical circuit or device expressed in volts.
Voltage can be thought of as being analogous to
the pressure in a water line.
Wall Temperature (Maximum Bulb)
The maximum operating bulb wall temperature.
Warm-Up Time to 90%
The time it takes for a HID lamp to reach 90% of
light output after being turned on.
Warm White
Refers to a color temperature around 3000K,
providing a yellowish-white light.
Watt
A unit of electrical power. Lamps are rated in watts
to indicate the rate at which they consume energy
(see KILOWATT HOUR).
Watt-Miser®
A Watt-Miser® lamp is a term used by GE
to indicate a reduced-wattage lamp with
performance characteristics (life, light output, etc.)
such that it can usually directly replace a higherwattage product.
Wattage Indicator Reduced
Indicates that this is a reduced wattage option for
lamps normally used in this application. Be sure to
check wattage, lumens and life to determine which
lamp is best suited to your needs.
Wavelength
The distance between two neighboring crests of a
traveling wave. The wavelength of light is between
400 and 700 nanometers.

Compact Fluorescent
Ballasts

TCLP Test
The Toxicity Characteristic Leaching Procedure
(TCLP) test, specified in the U.S. Resource
Conservation and Recovery Act (RCRA) of 1990, is
used to characterize fluorescent lamp waste as
hazardous or nonhazardous waste. The TCLP test
measures the ability of the mercury and/or lead in
a lamp to leach from a landfill into groundwater
(see ECOLUX).
THD
(See TOTAL HARMONIC DISTORTION.)
Terminal-to-Terminal Starting Lamp Voltage
(VRMS) (Minimum or Maximum)
The minimum or maximum voltage allowed into
lamp from ballast under varying conditions as
specified.
Total Harmonic Distortion (THD)
A measure of the distortion of the input current on
alternating-current (AC) power systems caused
by higher-order harmonics of the fundamental
frequency (60Hz in North America). THD is
expressed in percent and may refer to individual
electrical loads (such as ballast) or a total electrical
circuit or system in a building. ANSI C82.77
recommends THD not exceed 32% for individual
commercial electronic ballasts, although some
electrical utilities may require lower THDs on some
systems. Excessive THDs on electrical systems can
cause efficiency losses as well as overheating and
deterioration of system components.
Transients
High voltage surges through an electrical system
caused by lightning strikes to nearby transformers,
overhead lines or the ground. May also be caused
by switching of motors or compressors, as well as
by short circuits or utility system switching. Can
lead to premature ballast failure.
Troffer
A long, recessed lighting unit, usually installed in an
opening in the ceiling.
Two-Pin Compact Fluorescent Lamps
Type of lamps that have the glow bottle starter
built into the base of the lamp. Traditionally two-pin
lamps work with electromagnetic ballasts.
Underwriters Laboratories (UL)
A private organization which tests and
lists electrical (and other) equipment for
electrical and fire safety according to
recognized UL and other standards. A UL listing is
not an indication of overall performance. Lamps
are not UL listed except for compact fluorescent
lamp assemblies—those with screw bases and
built-in ballasts.
Uniform Product Code (UPC)
The 12-digit code on the saleable unit that is used
for scanning at the register.
Ultra
A common way of referring to high-efficiency GE
T8 family of lamps and ballast that performs better
than standard T8 lamps. Also refers to the system.
UltraMax® Ballast
A family of high-efficiency GE instant-start
electronic linear fluorescent ballasts designed to
optimize GE’s T8 Ultra lamps for enhanced system
energy savings. UltraMax® ballasts have a low
lamp current crest factor and virtually “read”
and adapt to incoming voltage from 108V to
305V. Other features include UL Type CC Anti-Arc
Rating and anti-striation control to eliminate lamp
striations and spiraling. GE also has an UltraMax®

Sign
Ballasts

Scotopic/Photopic (S/P) Ratio
This measurement accounts for the fact that of
the two light sensors in the retina, rods are more
sensitive to blue light (scotopic vision) and cones to
yellow light (photopic vision). The scotopic/photopic
(S/P) ratio is an attempt to capture the relative
strengths of these two responses. S/P is calculated
as the ratio of scotopic lumens to photopic
lumens for the light source on an ANSI reference
ballast. Cooler sources (higher color temperature
lamps) tend to have higher values of the S/P ratio
compared to warm sources.
Self-Ballasted Lamps
A discharge lamp with an integral ballasting device
allowing the lamp to be directly connected to a
socket providing line voltage (see CFL).
Series Lamp Operation
Refers to ballasts that employ a single current path
passing through all lamps operated by the ballast.
If one lamp should fail, companion lamps operated
by the same ballasts will also extinguish or dim.
Spacing-to-Mounting-Height Ratio
Ratio of fixture spacing (distance apart) to
mounting height above the work plane; sometimes
called spacing criterion. It is OK to have fixtures
spaced closer than the spacing criterion suggested
by the manufacturer but not farther, or you will get
dark spots in between fixtures.
Specification Series (SP) Colors
Energy-efficient, all-purpose, tri-phosphor
fluorescent lamp colors that provide good color
rendering. The CRI for SP colors is 70 or above and
varies by specific lamp type.
Specification Series Deluxe (SPX) Colors
Energy-efficient, all-purpose, tri-phosphor
fluorescent lamp colors that provide better color
rendering than Specification Series (SP) colors.
The CRI for SPX colors is 80 or above and varies by
specific lamp type. All GE CFL products use
SPX phosphors.
Specification Series Deluxe eXtreme (SPXX) Colors
A color designation for GE ceramic metal halide
lamps with superior color rendering ~ 90.
Specular Reflection
Reflection from a smooth, shiny surface, as
opposed to diffuse reflection.
Spiral® Lamp
GE trademark for its helical family of highefficiency, long-life compact fluorescent lamps.
Starcoat®
GE’s special barrier coating applied on the inside
of all GE T8 fluorescent lamps, as well as some
other lamp types, to enhance lamp life and deliver
superior lumen maintenance.
Starter
An electronic module or device used to assist in
starting a discharge lamp, typically by providing a
high-voltage surge (see IGNITOR).
Starting Temperature (Minimum)
The minimum ambient temperature at which the
lamp will start reliably.
T-12, T-8, T-5
A designation for the diameter of a tubular bulb in
eighths of an inch; T-12 is 12 eighths of an inch, or
1-1/2 inches; T-8 is 1 inch, and so on.
Task Lighting
Supplemental lighting provided to assist in
performing a localized task, e.g., a table lamp for
reading or an inspection lamp for fabric inspection.

T12
Fluorescent Ballasts

Power Factor Corrected
Ballasts that incorporate a means of Power Factor
Correction yielding power factor of 90% or greater.
Preheat Circuit
A type of fluorescent lamp-ballast circuit used with
the first commercial fluorescent lamp products. A
push-button or automatic switch is used to preheat
the lamp cathodes to a glow state before starting.
Product Code
Five-digit code to identify the product.
Programmed Rapid Start
Lamp starting method which preheats the lamp
filaments while not allowing the lamp to ignite and
then applies the open circuit voltage (OCV) to start
the lamp. This type of starting circuit keeps lampend blackening to a minimum and improves lamplife performance, especially in applications where
the lamps are frequently switched on and off.
PulseArc®
GE description for a type of metal halide lamp that
provides improved lumen maintenance for longer
useful life and extended relamp cycles. These
products are designed to operate on ballasts that
have ignitors to help with lamp starting.
Pulse Start
An HID ballast with a high voltage ignitor to start
the lamp.
Quartz
A name for fused silica or melted sand from which
many high-temperature containers are fashioned
in the lighting industry. Quartz looks like glass but
can withstand the high temperatures needed to
contain high intensity arc discharges.
Radiation
A general term for the release of energy in a “wave”
or “ray” form. All light is radiant energy or radiation,
as is heat, UV, microwaves, radio waves, etc.
Rapid Start Circuit
A fluorescent lamp-ballast circuit that utilizes
continuous cathode heating, while the system is
energized, to start and maintain lamp light output
at efficient levels. Rapid start ballasts may be either
electromagnetic, electronic or of hybrid designs.
Full-range fluorescent lamp dimming is only possible
with rapid start systems (see INSTANT START).
Rapid Start
Lamp starting method in which lamp filaments are
heated while open circuit voltage (OCV) is applied
to facilitate lamp ignition. A Rapid Start fluorescent
lamp has two pins at each end connected to the
filament. The filaments are heated by the ballast
to aid in starting. Some rapid start lamps may be
instant started without filament heat, for example
the F32T8 lamp.
Rated Lamp Life
For most lamp types, rated lamp life is the length
of time of a statistically large sample between first
use and the point when 50% of the lamps have
died. It is possible to define “useful life” of a lamp
based on practical considerations involving lumen
depreciation and color shift.
Room Cavity Ratio (RCR)
A shape factor (for a room, etc.) used in lighting
calculations.
RCR = 5H (L+W) / L x W, or, alternately,
RCR = (2.5) Total Wall Area / Floor Area.
Where H = height, L = length and W = width of
the room.
A cubical room will have an RCR of 10; the flatter
the room the lower the RCR.

T5
Fluorescent Ballasts

188

Multi-Vapor®
A GE brand for metal halide lamps.
National Electric Code (NEC)
A nationally accepted electrical installation code
to reduce the risk of fire, developed by the National
Fire Protection Association.
National Energy Standards for Fluorescent
Ballasts
A federal law enacted in 1988 that sets energy
standards for ballasts consistent throughout the
United States.
National Stock Number
The standardized part number used by the U.S.
Government for procurement.
NOM
Laboratory that sets safety standards for building
materials and electrical products for Mexico.
Non-PCB Capacitor
Capacitor used in ballasts to help provide power
factor correction. Contains no polychlorinated
biphenyls and meets EPA requirements.
Normal Power Factor
Ballasts with power factor less than .90 and do not
incorporate any means of Power Factor Correction.
Open Circuit Voltage (OCV)
Open Circuit Voltage measured across the socket
the lamp screws into, with the ballast powered
on. It is dangerous to stick a voltmeter into such a
socket without precise knowledge of the ballast
because exceedingly high voltages could be
present.
Operating Voltage
For electrical discharge lamps, this is the voltage
measured across the discharge when the lamp
is operating. It is governed by the contents of the
chamber and is somewhat independent of the
ballast and other external factors.
Parallel Lamp Operation
Refers to ballasts that employ multiple output
current paths from a single ballast to allow lamps
to operate independently of one another, allowing
other lamps operated by the ballast to remain lit
should companion lamp(s) fail.
PCB (Polychlorinated Biphenyls)
Chemical pollutant formerly used in ballast
capacitors that were part of ballasts. It is now
illegal to use PCBs and most such ballasts have
been replaced over time.
Phosphor
An inorganic chemical compound processed into
a powder and deposited on the inner glass surface
of fluorescent tubes and some mercury and metalhalide lamp bulbs. Phosphors are designed to
absorb short wavelength ultraviolet radiation and
to transform and emit it as visible light.
Potting
Material used to completely surround and cover
components of some magnetic and electronic
ballasts. Potting compound fulfills functions of
protecting components, dampening sound, and
dissipating heat.
Power Factor
Measurement of the relationship between the AC
source voltage and current. High-power factor
ballasts require less AC operating current at the
same wattage than an equivalent low-power
factor ballast. Formula: power factor equals input
watts divided by the product of line volts times line
amps (volt amps or VA).

T8
Fluorescent Ballasts

Lumens/Watts
A ratio expressing the luminous efficacy of a light
source. Typical lamp efficacies:
• Thomas Edison’s first lamp - 1.4 lpW
• Incandescent lamps - 10-40
• Halogen incandescent lamps - 20-45
• Fluorescent lamps - 35-105
• Mercury lamps - 50-60
• Metal halide lamps - 60-120
• High-pressure sodium lamps - 60-140
Note: The values above for discharge lamps do
not include the effect of the ballasts, which must
be used with those lamps. Taking ballast losses
into account reduces “system” or lamp-ballast
efficacies typically by 10-20% depending upon the
type of ballast used.
Lumen Maintenance
A measure of how well a lamp maintains its light
output over time.
Luminaire Efficiency
The ratio of total lumens emitted by a luminaire to
those emitted by the lamp or lamps used in that
luminaire.
Luminaire
A complete lighting unit consisting of a lamp,
ballast as required, together with the parts
designed to distribute the light, position and
protect the lamps and connect them to the power
supply. A luminaire is often referred to as a fixture.
Lux (lx)
A unit of illuminance or light falling onto a surface.
One lux is equal to one lumen per square meter.
Ten lux approximately equal one footcandle
(see FOOTCANDLE).
Mean Lumens
The average light output of a lamp over its rated
life. Based on the shape of the lumen depreciation
curve, for fluorescent and metal halide lamps,
mean lumens are measured at 40% of rated
lamp life. For mercury, high-pressure sodium and
incandescent lamps, mean lumen ratings refer
to lumens at 50% of rated lamp life (see LUMEN
MAINTENANCE).
Medium Base
Usually refers to the screw base typically used in
household incandescent lamps. There is also the
medium bi-pin base commonly used in T12 and T8
fluorescent lamps.
Metal Cases
Case design used in both magnetic and electronic
ballasts. These ballasts are grounded once they
are mounted to the fixture. They meet all safety
codes, some of which do not allow plastic in open
plenum areas.
Metal Halide Lamp
A high intensity discharge light source in which the
light is produced by the radiation from mercury,
plus halides of metals such as sodium, scandium,
indium and dysprosium. Some lamp types may
also utilize phosphor coatings. GE trade names
include: Multi-Vapor®, ConstantColor® CMH®,
PulseArc®, Staybright®, Watt-Miser®, ChromaFit
and Arcstream®.
Mogul Base
A screw base used on larger lamps, e.g. many
HID lamps.
Mounting Height
Distance from the bottom of the fixture to either
the floor or work plane, depending on usage.

Quick Reference
Guides

gelighting.com

Ballast cross reference matrix
Prod
Code

Description

Advance P/N

Universal P/N

OSI P/N

Howard P/N

96721
29672
29625
29627
96716
71832
29678

T8 INSTANT START BALLASTS
®

UltraMax Instant Start Multi-Voltage High Efficiency
GE132MAX-L/ULTRA
GE132MAX-N/ULTRA
GE232MAX-H/ULTRA
GE232MAX-L/ULTRA
GE232MAX-N/ULTRA
GE232MAX-N+
GE332MAX-H/ULTRA
GE332MAX-L/ULTRA
GE332MAX-N/ULTRA
GE332MAX-N+
GE432MAX-H/ULTRA
GE432MAX-L/ULTRA
GE432MAX-N/ULTRA
GE432MAX-N+
GE159MAX-N/ULTRA
GE259MAX-N/ULTRA

IOP-1P32LW-SC
IOP-1P32-SC
IOP-2P32HL-SC
IOP-2P32LW-SC
IOP-2P32-SC

B132IUNVEL-A
B132IUNVHE-A
B232IUNVHEH-A
B232IUNVEL-A
B232IUNVHE-A

IOP-3P32HL-90C-SC
IOP-3P32LW-SC
ICN-3P32-SC

B332IUNVHEH-A
B332IUNVEL-A
B332IUNVHE-A

IOP-4P32HL90CG
IOP-4P32LW-SC
ICN-4P32-SC

B432IUNVEL-A
B432IUNVHE-A

QHE 1X32T8/UNV ISN-SC-1
QHE 2X32T8/UNV ISN-SC-1

QHE 4X32T8/UNV ISH-SC-1

72273

GE-232-MV-L

72275

GE-232-MV-N

30199

GE-332-MV-H

30255

GE-332-MV-L

30192
30219

GE-332-MV-N
GE-432-MV-H

30262

GE-432-MV-L

30193
30195

GE-432-MV-N
GE-159-MV-N

30194

GE-259-MV-N

GE-286-HO-MV-N

UltraStart® T5 Programmed Rapid Start

IOP-2P59-SC
QTP 1X32T8/UNV ISL-SC/QHE
ICN-1P32-SC
B132IUNVHP-B
1X32T8/UNV ISN-SC
QTP 2X32T8/UNV ISH-SC/QHE
REL-2P32-HL-SC/VEL-2P32-HL-SC B232I120RHH-A/B232I277RHH-A 2X32T8/UNV ISH-SC
QTP 2X32T8/UNV ISL-SC/QHE
REL-2P32-LW-SC/VEL-2P32-LW-SC B232I120L-A/B232I277L-A
2X32T8/UNV ISL-SC
QTP 2X32T8/UNV ISN-SC/QHE
ICN-2P32-SC
B232IUNVHP-B
2X32T8/UNV ISN-SC
QTP 3X32T8/UNV ISH-SC/QHE
REL-3P32-HL-SC/VEL-3P32-HL-SC B332I120RHH-A/B332I277RHH-A 3X32T8/UNV ISH-SC
QTP 3X32T8/UNV ISL-SC/QHE
REL-3P32-LW-SC/VEL-3P32-LW-SC B332I120L-A/B332I277L-A
3X32T8/UNV ISL-SC
QTP 3X32T8/UNV ISN-SC/QHE
ICN-3P32-SC
B332IUNVHP-B
3X32T8/UNV ISN-SC
REL-4P32-HL-SC/VEL-4P32-HL-SC B432I120RHH-A/B432I277RHH-A QHE 4X32T8/UNV ISH-SC
QTP 4X32T8/UNV ISL-SC/QHE
REL-4P32-LW-SC/VEL-4P32-LW-SC B432I120L-A/B432I277L-A
4X32T8/UNV ISL-SC
QTP 4X32T8/UNV ISN-SC/QHE
ICN-4P32-SC
B432IUNVHP-B
4X32T8/UNV ISN-SC
RCN-2P59/VCN-2P59

RCN-2S86

GE-132-120-N
GE-132-277-N
GE-232-120-N
GE-232-277-N
GE-332-120-N
GE-332-277-N
GE-432-120-N
GE-432-277-N
GE-259-120-N
GE-259-277-N

RCN-1P32-SC
VCN-1P32-SC
RCN-2P32-SC
VCN-2P32-SC
RCN-3P32-SC
VCN-3P32-SC
RCN-4P32-SC
VCN-4P32-SC
RCN-2P59
VCN-2P59

Residential Grade ProLine® T8 120V
GE232-120-RES
GE432-120-RES

REB232-SC
REB4P32-SC

Electromagnetic T8 Ballasts

87125
87130

GEM232T8RS120
GEM232T8RS277

B259IUNVHP-B

QTP 2X59T8/UNV ISN-SC/QHE
2X59T8/UNV-ISN-SC

B259I120RHH/B259I277RHH

QHE 2X86T8HO/UNV-PSN-HTSCL/QHE2X59T8/UNV-ISH

R-2P32-TP
V-2P32-TP

B132I120RH-A
B132I277RH-A
B232I120RH-A
B232I277RH-A
B332I120RH-A
B332I277RH-A
B432I120RH-A
B4132I277RH-A

EPL2/32IS-120-277
EP2/32IS-120-277

EPL3/32IS-120-277
EP3/32IS-120-277
EPL4/32IS-120-277
EP4/32IS-120-277

QT1X32T8/120/ISN-SC
QT1X32T8/277/ISN-SC
QT2X32T8/120/ISN-SC
QT2X32T8/277/ISN-SC
QT3X32T8/120/ISN-SC
QT3X32T8/277/ISN-SC
QT4X32T8/120/ISN-SC
QT4X32T8/277/ISN-SC
QT2X59/120IS
QT2X59/277IS

B232I120RES-A
B432I120RES-A
M232SR120C
M232SR277C

UltraStart T8 Program Rapid Start

B132R120V5
B232SR120V5
B232SR277S50
B232SR277V5
B332SR120V5
B332SR277V5

99649
29726
72280

GE454MVPS90-E
GE454MVPSN1
GE180MVPS-D

B232PUNVHP-A

QTP 2X32T8/UNVPSN-TC
QTP 2X32T8/UNV PSX-TC
QHE2x32T8/UNV-PSH-HT

B332PUNVHP-A

QTP 3X32T8/UNVPSN-SC
See page 195 for warranty information.

ICN-2S28
ICN-2S24
ICN-2S39
ICN-2S54-90C
ICN-2S54
ICN4S5490C2LSG
ICN4S5490C2LS

B228PUNV115-D
B228PUNV95-D
B228PUNV-C
B224PUNV-D
B239PUNV-D
B254PUNV-D
B254PUNV-D

QTP2X28T5/UNVPSN NL
QTP2X39-24T5HO/UNVPSN NL
QTP2X39-24T5HO/UNVPSN NL
QTP 2X54T5HO/UNV PSN HT

B454PUNV-E

QTP2X54T5HO/UNVPSN NL
QTP 4X54T5HO/UNV PSN HTW
NL
QTP 4X54T5HO/UNV PSN HT
QTP1X80T5HO/UNVPSN NL

B240R120HP/B240R277HP
B234SR120M-A
B134SR120M-A
B340R120HP/B340R277HP
B260IUNVHP
B295SR120HP
B295SR277HP
B295SRUNVHP

QTP2X40T12/120RSN-SC
QTP1X40T12/120/277RSN-SC
QTP3X40T12/120/277RSN
QT2x96/120IS/QT2x96/277IS
QT2x96/120HO
QT2x96/277HO

EP2/54HO/PRS/MV/90C
EP2/54HO/PRS/120-277

T12 Fluorescent Ballasts

T12 ELECTRONIC BALLASTS

ProLine® T12 Multivolt 120V - 277V

24107
97498
72110
24109
24108
80162
80163
72109

GE-240-RS-MV-N
GE240RS120
GE140RS120-DIY
GE-340-RS-MV-N
GE-260-IS-MV-N
B295SR120HP
B295SR277HP
GE296HO-MV-N

R-140-TP
REL-2S40-SC/RELB-2S40-SC
REL-1S40-SC
R-3S34-TP
R2E75STP
REL-2P60-S-A/REL-2S110
VEL-2P75-S/VEL-2S110

T12 MAGNETIC BALLASTS

89711
89712
89720
86227
89717
80819
89714
89709
80644
89710
86139
86124
86341
86372
86381
86360
86379
86164
86171

GEM120PH120DIY
GEM120TC120DIY
GEM1FC16T9RS120
GEM1FC8T9RS120IP
GEM1FC12T9RS120
GEM220TS120DIY
GEM140HRS120DIY
GEM140RS120DIY
GEM230RS120
GEM240HRS120DIY
GEM240RS120IP
GEM240RS277IP
GEM240RS220
GEM196IS120IP
GEM196IS277
GEM296IS120IP
GEM296IS277IP
GEM296HORS120IP
GEM296HORS277
GESB-0412-12-IP
GESB-0620-24-IP
GESB-1224-24-IP
GESB-1240-46-IP
GESB-2040-46-IP
GESB-2448-46-IP

See page 195 for warranty information.

LC-14-20-C-TP
RLQ-120-TP
RMS-3240-TP-W
RLQS-122-TP-W
RS-22-32-TP-W
RS-2SP20-TP
R-140-TP
RL-140-TP
RM-2SP30-TP
RK-2S34-TP
R-2P840-TP
V2S40TP
MTM-2S40-TP
RSM175STP
VSM175STP
R2E75STP
V2E75STP
R-2S110-TP
V-2S110-TP

200H2
546BTCP
726VLHWSTCP
547RSWSTCP
449LRWSTCP
447LRVLHTCP
412LSLHTCP
413CTCP
573LTCP
420LTCP
446LSLHTCP
443LSLHTCP
754LTCP
822BRTCP
828BRTCP
806SLHTCP
827SLHTCP
480SLHTCP
487SLHTCP

ASB-0412-12-BL-TP
ASB-0620-24-BL-TP
ASB-1224-24-BL-TP
ASB-1240-46-BL-TP
ASB-2040-24-BL-TP
ASB-2448-46-BL-TP

USB-0412-12-IP
USB-0816-14-IP
USB-1024-14-IP
USB-2036-46-IP
USB-1632-24-IP
USB-2048-46-IP

191

HID Electromagnetic
Ballasts

190

RCN-2S32-SC
VCN-2S32-SC
IOP-2S32-SC
IOP-2S32-LW-SC
N/A
N/A
RCN-3S32-SC
VCN-3S32-SC
IOP-3S32-SC
IOP-3S32-SC

GE228MVPSH-A
GE228MVPS-A
B228PUNV-C0G1C
B224PUNV-COG1C
B239PUNV-DOG1C
GE254MVPS90-F
B254PUNV-DGE1C
GE254MVPS-D

72103
72104
72105
72106
72107
72108

®

GE-232-120-PS-N
GE-232-277-PS-N
GE232-MVPS-N
GE232-MVPS-L
GE-232-MVPS-H
GE-232-MVPS-XL
GE-332-120-PS-N
GE-332-277-PS-N
GE-332-MVPS-H
GE332-MVPS-N

99653
99655
47536
47534
47540
99651
47542
72279

Sign Ballasts

T8 PROGRAM START BALLASTS
29621
29622
96714
96720
29675
29671
29623
29624
29676
96715

QTP 4X32T8/UNVPSN-SC
QTP 4X32T8/UNV PSX-SC
QHE4x32T8/UNV-PSH-HT

HID Electronic
Ballasts

97782
97783

B432PUNVHP-A

Compact Fluorescent
Ballasts

ProLine® T8 Instant Start High-Performance

23680
23681
23671
23672
23673
23674
23675
23676
23677
23678

QTP 3X32T8/UNV PSX-SC
QHE3x32T8/UNV-PSH-HT

T5 ELECTRONIC PROGRAMMED START BALLASTS

ProLine® T8 Multivolt High Output 120V - 277V
30176

RZT-132
RZT-2S32
VZT-2S32
VZT-2S32
RZT-3S32
VZT-3S32

Howard P/N

Sign
Ballasts

GE-232-MV-H

B132R120V5
B232SR120V5
B232SR277S50
B232SR277V5
B332SR120V5
B332SR277V5

IOP-3S32-LW-SC
N/A
RCN-4S32-SC
VCN-4S32-SC
IOP-4S32-SC
IOP-4S32-LW-SC

OSI P/N

T12
Fluorescent Ballasts

30198

Universal P/N

T5 Fluorescent Ballasts

ProLine T8 Multivolt 120V - 277V
GE-132-MV-N

GE332-MVPS-L
GE-332-MVPS-XL
GE-432-120-PS-N
GE-432-277-PS-N
GE432-MVPS-N
GE432-MVPS-L
GE-432-MVPS-H

T8 Dimming

80353
80355
80362
80356
80357
80358

QHE 3X32T8/UNV ISH-SC-1

®

72269

Advance P/N

T5
Fluorescent Ballasts

72258
72259
49775
72262
72266
71421
71714
71717
71719
71422
71723
71725
71727
71423
49766
49767

Description

T8 Fluorescent Ballasts

T8
Fluorescent Ballasts

T8 Fluorescent Ballasts

Prod
Code

Quick Reference
Guides

gelighting.com

Ballast cross reference matrix (cont.)
Prod
Code

Description

Advance P/N

Universal P/N

OSI P/N

Robertson P/N

CFL ELECTRONIC

GEC213-MVPS-BES
GEC213-MVPS-SE
GEC213-MVPS-3W
GEC218-MVPS-BES
GEC218-MVPS-SE
GEC218-MVPS-3W
GEC226-MVPS-BES
GEC226-MVPS-SE
GEC226-MVPS-3W
C242UNVBES-IP
C242UNVSE-IP
C240PUNVHP-B-IP
C240SI120RH-IP
C240SI277RH-IP
C340SI120RH-IP
C340SI277RH-IP
GEM1CF579PH277
GEM1CF13PH120
GEM2CF13PH277
GEM2CF24PH277
GEM2FT36RS120
GEM2FT40RS120

87490
87501
87516
87531
87546
87561
87576
29377
89646

GEMH20-MLF-120
GEMH39-MSF-120
GEMH50-MSF-120
GEMH70-MSF-120
GEMH70-SLJ-MV
GEMH100-SLJ-MV
GEMH150-SLJ-MV
GE-MH-250-400-MA
GEMH250-400M-V50

ICF-2S26-BS
ICF-2S26-LD

C213UNVBS
C213UNVBES
C213UNVME00K
C218UNVBS
C218UNVBES
C218UNVME000K
C2642UNVBES-IP
C2642UNVSE-IP

IZT-2S42-M2-BS
IZT-2S42-M2-LS
REL-2TTS40
RCN-2TTP40-SC
VCN-2TTP40-SC
RCN-3TTP40-SC
VCN-3TTP40-SC
VL-1B9-TP-W
LC-13-TP
VH-2B13-TP-BLS
VH-2Q26-TP-BLS
R-2BS39-TP
R-2BS40-TP

C2642UNVBE
C2642UNVSE
C240PUNVHP-B-IP
C240SI120RH-IP
C240SI277RH-IP
C340SI120RH-IP
C340SI277RH-IP
4205F2P
4111H2P
4214PBES
4226PBES
4150P
4152P

Advance P/N

Universal P/N

ICF-2S18-BE
ICF-2S18-LD

PSG242TRMVBS
PSG242TRMV

AROMAT/VS P/N

QTP1X20MH/UNV F
QTP1X39MH/UNV F

M2012-27CK-5EUF
M3912-27CK-5EUF

IMH-70-G
IMG-70-G
IMG-100-A-BLS
IMG-150-H-BLS
IZTEMH4003PS

ECN70-120
ECN70-UNV
ECN100-UNV
ECN150-UNV

QTP1X70MH/UNV F
QTP1X70MH/UNV J
QTP1X100MH/UNV J

M7012-27CK-5EUF
M7012-27CK-5EUJ
M10012-27CK-5EUJ
M15012-27CK-5EUN-J

QHE1XxxxMH 208-277V

71A5593-001D
71A5543-500DT
71A5792-001D
71A5742-500DT
71A5892-001D
71A5842-500DT
71A5837-001D
71A5993-001D
71A6042-500DT
71A6092-001D
71A64F2-500DT
71A64E2-500D
71A6593-500
71A6553-500

P175MLTAC3M500K
P17548TAC3M500K
P250MLTAC4M500K
P25048TAC4M500K
P320MLTAC4M500K
P32048TAC4M500K
P320TRIAC4M502K
P350MLTAC4M500K
P40048TAC4M500K
P400MLTAC4M500K
P75048TAC5M500K
P750MLTAC5M500K
P1000MLTAC5M500K
P1000ML5AC5M500K

GEM175ML5AC3-55
GEM250ML5AC3-55
GEM400ML5AC4-55
GEM1000ML5AC4-55
GES100MLTLC3D-55
GES250ML5AC4-55
GES400ML5AC4-55

F-Can & Post Mount Metal Halide

86576
86578
86574
86563
86564
42670
80728

11210277CTC000C
11210506CTC000C
11210239CTC000I
1110245SCTC000I
1110246CTC000C
1110-247SC-TC
1111-247SCTC000I

72C5280-NP
72C5282-NP
72C5381-NP
72C5581-NP
72C5782-NP
72C6082-NP
72C6082-NP

F-Can & Post Mount HPS
1233142U000I
12210237CTC000I
1233154U000I

71A7907-001DB
72C7984-NP
71A8107-001DB

11210277CTC000C
11210506CTC000C
11210239CTC000I
1110245SCTC000I
1110246CTC000C
1110-247SC-TC
1111-247SCTC000I
1233142U000I
12210237CTC000I
1233154U000I

See page 195 for warranty information.

See page 195 for warranty information.

193

HID Electromagnetic
Ballasts

71A5390-001D
71A5340-500DT
71A5492-500D
71A5442-500DT
71A3042-001D
71A5570-001D
71A5750-001D
71A3542-001D
71A5750
71A6051-001D
71A6071-001D
71A6042-500DT
71A6542-001
71A6552-001
71A6572-001
71A6742-001
71A6772-001

71701
71702
71703
71704
71705
71706
71707

86605
86596
86606

EPXXXMRVASE

M50MLTLC3M500K
M70MLTLC3M500K
M7048TLC3M500K
M100MLTLC3M500K
M10048TLC3M500K
M150MLTLC3M500K
M15048TLC3M500K
M175ML5AC3M500K
M175MLTAC3M500K
M250ML5AC3M500K
M250MLTAC3M500K
M250ML5AC4M500K
M400ML5AC4M500K
M400MLTAC4M500K
M40048TAC4M500K
M100048TAC5M500K
M1000ML5AC5M500K
M1000MLTAC5M500K
M150048TAC5M500K
M1500MLTAC5M500K

S50MLTLC3M500K
S70MLTLC3M500K
S7048TLC3M500K
S100MLTLC3M500K
S10048TLC3M500K
S150MLTLC3M500K
S15048TLC3M500K
S250ML5AC4M500K
S250MLTAC4M500K
S400ML5AC4M500K
S400MLTAC4M500K
S40048TAC4M500K
S100048TAC5M500K
S1000ML5AC5M500K
S1000MLTAC5M500K

HID Lamp-Ballast Kits

ECN20-120
ECN39-120

71A5181-500D
71A5280-500D

71A7801-001D
71A7971-001D
71A7941-001D
71A8001-001D
71A8041-001D
71A8172-001D
71A8142-001D
71A8251-001D
71A8271-001D
71A8453-001D
71A8473-001D
71A8443-001D
71A8743-001
71A8753-001
71A8773-001

HID Electronic
Ballasts

192

GEP175MLTAC3-5
GEP17548TAC3-5
GEP250MLTAC4-5
GEP25048TAC4-5
GEP320MLTAC4-5
GEP32048TAC4-5
GEP320TRIAC4-5
GEP350MLTAC4-5
GEP40048TAC4-5
GEP400MLTAC4-5
GEP75048TAC5-5
GEP750MLTAC5-5
GEP1000MLTAC5-5
GEP1000ML5AC5-5

PSG242TRMVBS
PSG242TRMV

GES50MLTLC3D-5
GES70MLTLC3D-5
GES7048TLC3D-5
GES100MLTLC3D-5
GES10048TLC3D-5
GES150MLTLC3D-5
GES15048TLC3D-5
GES250ML5AC4-5
GES250MLTAC4-5
GES400ML5AC4-5
GES400MLTAC4-5
GES40048TAC4-5
GES100048TAC5-5
GES1000ML5AC5-5
GES1000MLTAC5-5

AROMAT/VS P/N

Compact Fluorescent
Ballasts

Pulse Start

86885
86876
86935
86926
86959
86952
86968
86984
86999
87008
46936
46934
72281
72282

PSM218CQMVBS
PSM218CQMV

87152
86587
86456
87074
87068
87094
87087
87214
87121
87215
87164
87198
87048
87218
87056

OSI P/N

Sign
Ballasts

GEM50MLTLC3D-5
GEM70MLTLC3D-5
GEM7048TLC3D-5
GEM100MLTLC3D-5
GEM10048TLC3D-5
GEM150MLTLC3D-5
GEM15048TLC3D-5
GEM175ML5AC3-5
GEM175MLTAC3-5
GEM250ML5AC3-5
GEM250MLTAC3-5
GEM250ML5AC4-5
GEM400ML5AA4-5
GEM400MLTAA4-5
GEM40048TAC4-5
GEM100048TAC5-5
GEM1000ML5AA5-5
GEM1000MLTAA5-5
GEM150048TAC5-5
GEM1500MLTAC5-5

OSI P/N

PSM213CQMVBS
PSM213CQMV

RMH-20-E
RMH-39-K

HID Electromagnetic Ballasts
Metal Halide
86824
86847
86839
86675
86667
86718
86711
87210
86741
87211
86765
87212
72300
72149
86803
86650
87213
86655
86693
86698

QTP1/2X13CF/UNVBS
QTP1/2X13CF/UNVTS
QTP 1/2x13CF/UNV
QTP1/2X18CF/UNVBS
QTP1/2X18CF/UNVTS
QTP 1/2x18CF/UNV
QTP2X26CF/UNVBS
QTP2X26CF/UNVTS
QTP 1/2x26CF/UNV
QTP2X26/32/42CF/UNVPM
QTP2X26/32/42CF/UNVTM
QTP2X40TT5/120/277PSN-F
QHE2X40DL/UNV ISN-SC
QHE2X40DL/UNV ISN-SC
QHE3X40DL/UNV ISN-SC
QHE3X40DL/UNV ISN-SC

Universal P/N

T12
Fluorescent Ballasts

Description

HID Electronic Ballasts

ICF-2S13-BE
ICF-2S13-LD

Advance P/N

T5
Fluorescent Ballasts

71428
71429
71430
71432
71433
71434
71443
71444
71445
47506
47509
80683
80680
80681
80690
80691
87634
87533
87655
87700
87623
87625
Prod
Code

Description

HID Electromagnetic Ballasts
High Pressure Sodium

T8
Fluorescent Ballasts

Compact Fluorescent Ballasts

Prod
Code

Quick Reference
Guides

gelighting.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2008:02:15 14:14:57-05:00
Modify Date                     : 2008:06:13 11:25:03-04:00
Metadata Date                   : 2008:06:13 11:25:03-04:00
Creator Tool                    : PScript5.dll Version 5.2.2
Document ID                     : uuid:02379240FADBDC118090A7F05934CEB7
Instance ID                     : uuid:26fd38f6-738b-491f-9a42-74d6da0fd528
Derived From Instance ID        : uuid:6104ece2-28d5-401f-87a9-b126db55ba8e
Derived From Document ID        : uuid:d632b817-c811-4db6-988e-f72371d7dd7e
Format                          : application/pdf
Title                           : 2008 Ballast Cat Revised.pdf
Creator                         : 211008578
Has XFA                         : No
Page Count                      : 98
Author                          : 211008578
EXIF Metadata provided by EXIF.tools

Navigation menu