CE EMC REPORT 178525
178563 Emc Report 178563_EMC__Report 178563_EMC__Report CertsReports 178563 ProductFiles assets.mhint
178532 Emc Report 178532_EMC__Report 178532_EMC__Report CertsReports 178532 ProductFiles assets.mhint
178556 Ce Certification Channel Well 178556_CE_certification--Channel_well 178556_CE_certification--Channel_well CertsReports 178556 ProductFiles assets.mhint
178556 Emc Report 178556_EMC__Report 178556_EMC__Report CertsReports 178556 ProductFiles assets.mhint
178570 Emc Report 178570_EMC__Report 178570_EMC__Report CertsReports 178570 ProductFiles assets.mhint
2016-04-06
: Pdf 178525 Emc Report 178525_EMC__Report CertsReports 178525 ProductFiles
Open the PDF directly: View PDF .
Page Count: 15
Download | |
Open PDF In Browser | View PDF |
Compliance Certification Services Inc. Report No.: 81014101-D Refer No.: 70620101-D Date of Issue: October 22, 2008 EMC UPDATE TEST REPORT For Channel Well Technology Co., Ltd. Switching Power supply Model: PSHxy-zz (x= 350, 400, 450, 500, 550, 600, 650, 700, 750, 850; y=P, Q, R, S, V, P1, Q1, R1, S1, V1, H1, U1, F; z= 0-9, A-Z or Blank); GREATPOWER X14S4P3 500W; GREATPOWER X14S4P3 550W; GREATPOWER X14S4P4 600W; GREATPOWER X14S4P4 650W; GREATPOWER X14S4P4 700W; GREATPOWER X14S4P4 750W; GREATPOWER X14S8P4 850W; CWT-abz (a = 500, 550, 600, 650, 700, 750, 850; b=P, Q, R, S, V; z = 0-9,A-Z or blank); NRP-MC651; NRP-MC751; NRP-MC851 Trade Name: CWT Revision: 03 Description of Rev. 03: 1. Applicant modifies applicant’s address as per customer required. (Please refer to page 3 on this report) 2. Applicant adds alternate Input and Output rating for model number: PSH-850V1-zz. (Please refer to Page 4 for input and Page 6 for output.) 3. Applicant adds alternate schematic and layout (only secondary different) and DC fan source to re-test. (Please refer to have ** mark items on this report) 4. Other information, please refer to the 51104105, 61012102, 70620101 and this test report. Approved by: Reviewed by: Robert Huan Section Manager of Linkou Laboratory Compliance Certification Services Inc. Julia Wei Senior Specialist of Linkou Laboratory Compliance Certification Services Inc. Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. Ltd. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 Total Page: 15 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D Refer No.: 70620101-D Date of Issue: October 22, 2008 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION .....................................................................................................3 2 EUT DESCRIPTION............................................................................................................................4 3 TEST METHODOLOGY.....................................................................................................................7 3.1 DECISION OF FINAL TEST MODE ........................................................................................7 4 SETUP OF EQUIPMENT UNDER TEST...........................................................................................7 5 LABORATORY ACCREDITATIONS AND LISTINGS ...................................................................8 6 5.1 MEASURING INSTRUMENT CALIBRATION.......................................................................8 5.2 TEST AND MEASUREMENT EQUIPMENT ..........................................................................8 TEST RESULTS ................................................................................................................................10 APPENDIX I - PHOTOGRAPHS OF TEST SETUP ................................................................................14 Page 2 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D 1 Refer No.: 70620101-D Date of Issue: October 22, 2008 TEST RESULT CERTIFICATION Applicant: Channel Well Technology Co., Ltd. NO. 222, SEC. 2, NANKAN RD., LUJHU TOWNSHIP, TAOYUAN HSIEN, TAIWAN, R.O.C. Manufacturer: Channel Well Technology Co., Ltd. 3rd F1-2, 888, Jing-Gwo Rd., Taoyuan City, Taiwan, R.O.C. Equipment Under Test: Switching Power supply Trade Name: CWT Model: PSHxy-zz (x= 350, 400, 450, 500, 550, 600, 650, 700, 750, 850; y=P, Q, R, S, V, P1, Q1, R1, S1, V1, H1, U1, F; z= 0-9, A-Z or Blank); GREATPOWER X14S4P3 500W; GREATPOWER X14S4P3 550W; GREATPOWER X14S4P4 600W; GREATPOWER X14S4P4 650W; GREATPOWER X14S4P4 700W; GREATPOWER X14S4P4 750W; GREATPOWER X14S8P4 850W; CWT-abz (a = 500, 550, 600, 650, 700, 750, 850; b=P, Q, R, S, V; z = 0-9,A-Z or blank); NRP-MC651; NRP-MC751; NRP-MC851 Detailed EUT Description: See Item 2 of this report Date of Test: October 15 ~ 16, 2008 Applicable Standard Class / Limit Test Result FCC Part 15 Subpart B, IC ICES-003 Class B No non-compliance noted Deviation from Applicable Standard None The above equipment was tested by Compliance Certification Services Inc. for compliance with the requirements set forth in the FCC Rules and Regulations Part 15, Subpart B and the measurement procedures were according to ANSI C63.4. This said equipment in the configuration described in this report shows the maximum emission levels emanating from equipment are within the compliance requirements. Page 3 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D 2 Refer No.: 70620101-D Date of Issue: October 22, 2008 EUT DESCRIPTION Product Switching Power supply Trade Name CWT Model PSHxy-zz (x= 350, 400, 450, 500, 550, 600, 650, 700, 750, 850; y=P, Q, R, S, V, P1, Q1, R1, S1, V1, H1, U1, F; z= 0-9, A-Z or Blank); GREATPOWER X14S4P3 500W; GREATPOWER X14S4P3 550W; GREATPOWER X14S4P4 600W; GREATPOWER X14S4P4 650W; GREATPOWER X14S4P4 700W; GREATPOWER X14S4P4 750W; GREATPOWER X14S8P4 850W; CWT-abz (a = 500, 550, 600, 650, 700, 750, 850; b=P, Q, R, S, V; z = 0-9,A-Z or blank); NRP-MC651; NRP-MC751; NRP-MC851 Housing Type Plastic EUT Power Rating see as below AC Power Cord Type Unshielded, 1.8m (Detachable) Note: 1. The means of xy-zz (x= 350, 400, 450, 500, 550, 600, 650, 700, 750, 850; y=P, Q, R, S, V P1, Q1, R1, S1, V1, H1, U1, F; z= 0-9, A-Z or Blank) on model number are list as below: x represents max. Input / Output wattage; x = 350, 400, 450, 500, 550, 600, 650, 700, 750, 850; for PSHxy-zz AC Input Power Rating Model VAC A Hz 100-240 5-2.5 PSH350y-zz 115-230 5/2.5 47-63 PSH400y-zz 200-240 2.3 230 2.5 100-240 6-3 PSH450y-zz 115-230 6/3 PSH500y-zz 47-63 200-240 3 GREATPOWER X14S4P3 500W; CWT-500bz 230 3 PSH550y-zz 100-240 8-4 PSH600y-zz 115-230 8/4 PSH650y-zz 200-240 4 47-63 GREATPOWER X14S4P3 550W GREATPOWER X14S4P4 600W 230 4 GREATPOWER X14S4P4 650W; CWT-550bz; CWT-600bz; CWT-650bz PSH700y-zz 100-240 10-5 PSH750y-zz 115-230 10/5 GREATPOWER X14S4P4 700W 200-240 5 47-63 GREATPOWER X14S4P4 750W GREATPOWER X14S8P4 850W; 230 5 CWT-700bz; CWT-750bz; CWT-850bz; PSH850y-zz NRP-MC651 100-240V 8/4 47-63 NRP-MC751; NRP-MC851 100-240V 10/5 47-63 PSH850V1-zz **100-240V **12 **50/60 Page 4 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D Model PSH350y-zz PSH400y-zz PSH450y-zz PSH500y-zz GREATPOWER X14S4P3 500W; CWT-500bz PSH550y-zz GREATPOWER X14S4P3 550W; CWT-550bz PSH600y-zz GREATPOWER X14S4P4 600W; CWT-600bz PSH650y-zz GREATPOWER X14S4P4 650W; CWT-650bz PSH700y-zz GREATPOWER X14S4P4 700W; CWT-700bz PSH750y-zz GREATPOWER X14S4P4 750W; CWT-750bz; NRP-MC751 PSH850y-zz GREATPOWER X14S8P4 850W; CWT-850bz; NRP-MC851 **+12V3, +12V4 for Optional Model **PSH850V1-zz Refer No.: 70620101-D Date of Issue: October 22, 2008 DC Output Power Rating +5V (A) +3.3V (A) +12V1 (A) +12V2 (A) +12V3 (A) +12V4 (A) -12V (A) +5Vsb (A) 21 12 28 14 28 15 28 22 20 30 20 30 22 30 10 10 14 14 14 14 18 15 15 15 15 16 16 18 ------------16 --------------- 0.8 0.8 0.8 0.8 0.8 0.8 0.8 3 3 3 3 3 3 3 16 22 18 18 16 --- 0.8 3 28 30 18 18 16 --- 0.8 3 24 24 18 18 16 --- 0.8 3 28 30 18 18 18 18 0.8 3 24 24 18 18 18 18 0.8 3 28 30 18 18 18 18 0.8 3 24 24 18 18 18 18 0.8 3 28 30 18 18 18 18 0.8 3 24 24 18 18 18 18 0.8 3 28 30 18 18 18 18 0.8 3 24 24 18 18 18 18 0.8 3 30 30 18 18 30 30 0.8 3 DC Output Power Rating +5V (A) +3.3V (A) +12V (A) -12V (A) +5Vsb (A) 30 30 70 0.8 3 Page 5 Watt 350W 400W 450W 500W 550W 600W 650W 700W 750W 850W Watt 850W Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D Refer No.: 70620101-D Date of Issue: October 22, 2008 y represents the form factor; y=P, Q, R, S, V, P1, Q1, R1, S1, V1, H1, U1, F EMI Board & y WxLxH FAN PCB No. x 1 Main Board 150 x 140 x 86.0 mm 80mm x 1 P; P1 Q; Q1 R; R1 150 x 140 x 86.0 mm (Cable Management) 80mm x 1 150 x 160 x 86.0 mm 150 x 160 x 86.0 mm (Cable Management) 120mm x 1 on top 150 x 160 x 86.0 mm On middle x 2 On Side x 2 U1 H1 150 x 160 x 86.0 mm (Cable Management) 150 x 140 x 86.0 mm 150 x 160 x 86.0 mm 150 x 160 x 86.0 mm (Cable Management) 150 x 160 x 86.0 mm 150 x 160 x 86.0 mm F 150 x 160 x 86.0 mm S; S1 V; V1 Separate Combine 350W, 400W 450W, 500W 550W, 600W Separate On Side x 2 120mm x 1 140mm x 1 120mm x 1 140mm x 1 140mm x 1 140mm x 1 Combine Combine Combine --- 140mm x 1 Combine -- PCB No. x 2 350W, 400W 450W, 500W 550W, 600W 650W, 700W 750W 350W, 400W 450W, 500W 550W, 600W 650W, 700W 750W; **850W for Case V and R Combine 55W 750W 500W; 550W; 600W; 650W z represents cosmetic changes; z = 0-9, A-Z, or Blank 2. 3. 4. 5. ** 6. Client consigns four model samples (Model number: PSH350Y, PSH450Y, PSH600P, PSH750Y) to test. Therefore, testing Lab. just guarantees the units, which have been tested. Client consigns four model samples (Model number: PSH850V) to test. Therefore, testing Lab. just guarantees the units, which have been tested. The means of “x (x= 500, 550, 600, 650, 700, 750, 850F)” on model number is list as below: DC Output Power Rating TOTAL POWER Model Watt +5V +3.3V +12V -12V +5Vsb +5V& +3.3V (A) (A) (A) (A) (A) For y = P1, Q1, R1, S1, V1, H1 or U1 ( y = H1 for x = 550 only, y = U1 for x = 750 only) 28 30 36 0.8 3.0 140 PSH500y-zz 500W 16 22 36 0.8 3.0 130 28 30 41 0.8 3.0 140 PSH550y-zz 550W 24 24 41 0.8 3.0 140 28 30 48 0.8 3.0 180 PSH600y-zz 600W 180 24 24 48 0.8 3.0 28 30 52 0.8 3.0 180 PSH650y-zz 650W 180 24 24 52 0.8 3.0 28 30 56 0.8 3.0 180 PSH700y-zz 700W 180 24 24 56 0.8 3.0 28 30 60 0.8 3.0 180 PSH750y-zz 750W 180 24 24 60 0.8 3.0 PSH850y-zz 30 30 62 0.8 3.0 180 850W PSH850V1-zz **30 **30 **70 **0.8 **3.0 **180 **850W Client consigns four model samples (Model number: PSH750U) to test. Therefore, testing Lab. just guarantees the units, which have been tested. Client consigns four model samples (Model number: PSH850V1-ZZ) to test. Therefore, testing Lab. just guarantees the units, which have been tested. Page 6 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D 3 Refer No.: 70620101-D Date of Issue: October 22, 2008 TEST METHODOLOGY 3.1 DECISION OF FINAL TEST MODE 1. The following test mode(s) were scanned during the preliminary test: Mode 1 Full Load – PSH850V1-ZZ 2. After preliminary test, found mode 1 producing the highest emission level, used this mode for all final test. 4 SETUP OF EQUIPMENT UNDER TEST Setup Diagram See test photographs attached in Appendix 1 for the actual connections between EUT and support equipment. Support Equipment No. Equipment Model No. Serial No. FCC ID Trade Name Data Cable Power Cord 1 PC DX-6120 SGH53102TR FCC DoC HP N/A Unshielded, 1.8m 2 Monitor 959NF AQ19H2RT706121B FCC DoC SAMSUNG 3 Modem DM-1414 304012262 IFAXDM1414 ACEEX Unshielded, 1.8m Unshielded, 1.8m 4 Printer STYLUS C60 DR3K041515 FCC DoC EPSON Unshielded, 1.8m Unshielded, 1.8m 5 PS/2 Keyboard Y-SJ17 SY520U00642 FCC DoC Logitech Unshielded, 1.8m N/A 6 PS/2 Mouse M-SBF69 HCA51604416 DZL211029 Logitech Unshielded, 1.8m N/A Shielded, 1.8m with two cores Unshielded, 1.8m Note: Grounding was in accordance with the manufacturer’s requirements and conditions for the intended use. Page 7 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D 5 Refer No.: 70620101-D Date of Issue: October 22, 2008 LABORATORY ACCREDITATIONS AND LISTINGS 5.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment utilized to perform the tests documented in this report has been calibrated once a year or in accordance with the manufacturer's recommendations, and is traceable under the IEC 17025 to international or national standards. Equipment has been calibrated by accredited calibration laboratories. 5.2 TEST AND MEASUREMENT EQUIPMENT The following list contains measurement equipment used for testing. The equipment conforms to the requirement of CISPR 16-1, ANSI C63.2 and other required standards. Calibration of all test and measurement, including any accessories that may effect such calibration, is checked frequently to ensure the accuracy. Adjustments are made and correction factors are applied in accordance with the instructions contained in the respective manual. Equipment Used for Emission Measurement Conducted Emission Test Site # 3 Name of Equipment Manufacturer Model Serial Number Calibration Due EMI Test Receiver R&S ESCS30 845552/030 04/08/2009 LISN R&S ENV216 100074 12/03/2008 LISN FCC FCC-LISN-50/ 250-16-2-07 06013 10/12/2009 Test S/W LabVIEW 6.1 (CCS Conduction Test SW Version_01) Note: The measurement uncertainty is less than +/-1.7806dB, which is evaluated as per the NAMAS NIS 81 and CISPR/A/291/CDV. Page 8 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D Refer No.: 70620101-D Date of Issue: October 22, 2008 Open Area Test Site # 5 Name of Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer ADVANTEST R3132 91700456 N.C.R EMI Test Receiver R&S ESVS10 846285/016 06/06/2009 Bilog Antenna TESEQ CBL 6112D 23190 06/27/2009 Pre-Amplifier WIRELESS FPA-6592G 060010 08/29/2009 Turn Table CCS CC-T-1F N/A N.C.R Antenna Tower CCS CC-A-1F N/A N.C.R Controller CCS CC-C-1F 04 N.C.R RF Switch ANRITSU MP59B 10877 N.C.R Site NSA CCS N/A N/A 11/23/2008 Test S/W LabVIEW 6.1 (CCS OATS EMI SW V2.7) Note: The measurement uncertainty is less than +/- 3.8906dB, which is evaluated as per the NAMAS NIS 81 and CISPR/A/291/CDV. Page 9 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D 6 Refer No.: 70620101-D Date of Issue: October 22, 2008 TEST RESULTS Line Conducted Emission CCS Conduction Test 3 Model No. PSH850V1-ZZ 6dB Bandwidth 9 kHz Environmental Conditions 25oC, 57% RH Test Mode Mode 1 Tested By Alex Tsai Line L1 NO. Frequency QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average Remark reading reading factor result result limit limit margin margin (MHz) (dBuV) (dBuV) (dB) (dBuV) (dBuV) (dBuV) (dBuV) (dB) (dB) (Pass/Fail) 1 0.1773 35.80 35.30 9.70 45.50 45.00 64.61 54.61 -19.11 -9.61 Pass 2 0.2437 24.60 24.30 9.70 34.30 34.00 61.97 51.97 -27.67 -17.97 Pass 3 0.2633 31.60 31.50 9.70 41.30 41.20 61.33 51.33 -20.03 -10.13 Pass 4* 0.3531 30.09 29.99 9.71 39.80 39.70 58.89 48.89 -19.09 -9.19 Pass 5 11.9898 15.86 13.36 10.24 26.10 23.60 60.00 50.00 -33.90 -26.40 Pass 6 18.5237 26.62 17.42 10.38 37.00 27.80 60.00 50.00 -23.00 -22.20 Pass 7 20.4469 35.77 25.47 10.43 46.20 35.90 60.00 50.00 -13.80 -14.10 Pass REMARKS: L1 = Line One (Live Line) Page 10 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D Refer No.: 70620101-D Date of Issue: October 22, 2008 CCS Conduction Test 3 Model No. PSH850V1-ZZ 6dB Bandwidth 9 kHz Environmental Conditions 25oC, 57% RH Test Mode Mode 1 Tested By Alex Tsai Line L2 NO. Frequency QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average Remark reading reading factor result result limit limit margin margin (MHz) (dBuV) (dBuV) (dB) (dBuV) (dBuV) (dBuV) (dBuV) (dB) (dB) (Pass/Fail) 1* 0.1773 41.90 41.50 9.70 51.60 51.20 64.61 54.61 -13.01 -3.41 Pass 2 0.2437 32.50 32.40 9.70 42.20 42.10 61.97 51.97 -19.77 -9.87 Pass 3 0.3531 25.69 25.39 9.71 35.40 35.10 58.89 48.89 -23.49 -13.79 Pass 4 12.2477 24.76 23.46 10.24 35.00 33.70 60.00 50.00 -25.00 -16.30 Pass 5 20.6148 34.77 24.67 10.43 45.20 35.10 60.00 50.00 -14.80 -14.90 Pass 6 21.7149 27.81 15.61 10.49 38.30 26.10 60.00 50.00 -21.70 -23.90 Pass REMARKS: L2 = Line Two (Neutral Line) Page 11 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D Refer No.: 70620101-D Date of Issue: October 22, 2008 Radiated Emission CCS Radiated Test OATS 5 Model No. PSH850V1-ZZ Test Mode Mode 1 Environmental Conditions 34oC, 64% RH 6dB Bandwidth 120 kHz Antenna Pole Vertical Antenna Distance 10m Tested By Steve Cheng Detector Function: Quasi-peak. No. Frequency Reading Margin Degree Height (MHz) (dBuV) (dB) (°) (cm) 1 41.26 10.01 13.53 23.54 30.00 -6.46 222.60 100.00 QP 2 59.32 16.96 7.76 24.72 30.00 -5.28 276.60 100.00 QP 3 68.49 17.69 7.78 25.47 30.00 -4.53 33.90 100.00 QP 4 137.18 8.89 15.28 24.18 30.00 -5.82 106.80 100.00 QP 5 157.50 9.58 14.32 23.90 30.00 -6.10 194.50 100.00 QP 6 229.16 8.14 15.80 23.93 30.00 -6.07 81.40 100.00 QP 7 311.40 11.82 20.16 31.98 37.00 -5.02 154.30 324.30 QP 8 374.60 7.74 22.75 30.49 37.00 -6.51 53.70 324.30 QP 9 456.60 8.32 24.44 32.76 37.00 -4.24 311.70 184.00 QP 10 526.20 3.27 25.16 28.43 37.00 -8.57 10.30 146.20 QP 11 687.30 2.57 28.00 30.57 37.00 -6.43 321.10 135.10 QP 12 775.50 2.74 28.90 31.65 37.00 -5.35 10.20 112.50 QP 13 867.30 2.55 29.42 31.97 37.00 -5.03 109.70 100.00 QP 14 933.30 0.36 29.87 30.23 37.00 -6.77 76.90 100.00 QP REMARKS: Correction Result Limit Factor(dB/m) (dBuV/m) (dBuV/m) Remark The other emission levels were very low against the limit. Page 12 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D Refer No.: 70620101-D Date of Issue: October 22, 2008 CCS Radiated Test OATS 5 Model No. PSH850V1-ZZ Test Mode Mode 1 Environmental Conditions 34oC, 64% RH 6dB Bandwidth 120 kHz Antenna Pole Horizontal Antenna Distance 10m Tested By Steve Cheng Detector Function: Quasi-peak. No. Frequency Reading Margin Degree Height (MHz) (dBuV) (dB) (°) (cm) 1 44.34 12.96 11.98 24.94 30.00 -5.06 49.80 399.70 QP 2 66.38 14.85 7.74 22.60 30.00 -7.40 314.00 399.70 QP 3 115.74 9.16 15.44 24.61 30.00 -5.39 239.30 399.70 QP 4 172.62 8.10 13.80 21.90 30.00 -8.10 47.70 399.70 QP 5 229.67 10.10 15.85 25.95 30.00 -4.05 269.60 399.70 QP 6 289.99 10.55 19.49 30.04 37.00 -6.96 20.60 399.70 QP 7 348.80 5.67 21.77 27.43 37.00 -9.57 321.40 367.10 QP 8 400.00 4.41 23.71 28.12 37.00 -8.88 304.80 367.10 QP 9 431.80 5.68 24.18 29.86 37.00 -7.14 149.50 187.20 QP 10 523.50 4.52 25.08 29.60 37.00 -7.40 209.10 147.10 QP 11 659.90 4.08 27.79 31.87 37.00 -5.13 0.70 136.30 QP 12 761.30 1.60 28.84 30.44 37.00 -6.56 353.90 117.10 QP 13 865.50 0.34 29.40 29.74 37.00 -7.26 101.70 100.40 QP 14 905.10 2.19 29.88 32.07 37.00 -4.93 71.00 100.40 QP REMARKS: Correction Result Limit Factor(dB/m) (dBuV/m) (dBuV/m) Remark The other emission levels were very low against the limit. Page 13 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D Refer No.: 70620101-D Date of Issue: October 22, 2008 APPENDIX I - PHOTOGRAPHS OF TEST SETUP LINE CONDUCTED EMISSION TEST Page 14 Rev. 03 Compliance Certification Services Inc. Report No.: 81014101-D Refer No.: 70620101-D Date of Issue: October 22, 2008 RADIATED EMISSION TEST Page 15 Rev. 03
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Modify Date : 2008:10:22 17:15:53+08:00 Create Date : 2008:10:22 17:14:24+08:00 Page Count : 15 Creation Date : 2008:10:22 09:14:24Z Mod Date : 2008:10:22 09:14:24Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : Harris Metadata Date : 2008:10:22 09:14:24Z Creator : Harris Title : CE EMC TEST REPORT Page Mode : UseNone Tagged PDF : YesEXIF Metadata provided by EXIF.tools