Product Detail Manual

2014-09-27

: Pdf 189912-Attachment 189912-Attachment 000334 Batch8 unilog

Open the PDF directly: View PDF PDF.
Page Count: 40

DownloadProduct Detail Manual
Open PDF In BrowserView PDF
TW Series

Switches & Pilot Lights

(14/05/22)

ø22 TW Series Selection Guide
Function
Category

Flush

Extended

Pushbutton
Extended w/Full Shroud
Momentary/Maintained

ø29mm Mushroom

ø40mm Mushroom

ABW1
AOW1
7

ABW2
AOW2
7

ABFW2
AOFW2
7

ABW3
AOW3
7

ABW4
AOW4
8

Shape

Model
Page
Function
Category

Pushbutton
ø40mm Mushroom
w/Full Shroud
Momentary

ø29mm Mushroom

ø40mm Mushroom

ø40mm Mushroom

ø29mm Mushroom

Pushlock Turn Reset

Pushlock Turn Reset

Push Turn Lock

Pushlock Key Reset

ABGW4
8

AVW3
8

AVW4
8

AJW4
8

AXW3
8

Shape

Model
Page
Function
Category

ø40mm Mushroom
Pushlock Key Reset

Pushbutton
ø40mm Mushroom
Square Flush
Square Extended
Push Pull
Momentary/Maintained

Shape

Model

AXW4

AYW4

Page

9

9

Function
Category

ABQW1
AOQW1
9

ABQW2
AOQW2
9

Pilot Light
Flush
(Non-marking/Marking)

Dome

Square Flush
(Marking)

APW2

APQW1B

10

10

Shape

Model
Page

2

	APW1
	APW1B
10

(14/05/22)

TW Series Selection Guide ø22
Function
Category

Illuminated Pushbutton (LED/Incandescent)
Extended w/Full Shroud
Square Extended
ø29mm Mushroom
Extended
(Marking)
Pushlock Turn Reset
(Non-marking/Marking) (Non-marking/Marking)

ø40mm Mushroom
Pushlock Turn Reset

Shape

Part No.
Page
Function
Category

	
	

ALW2, ALW2B,
AOLW2, AOLW2B
12, 13

	 ALFW2, AOLFW2
	 ALFW2B, AOLFW2B
14, 15

	ALQW2B
	AOLQW2B
16

	AVLW3
	AVLW3B
17

	AVLW4
	AVLW4B
18

Illuminated Pushbutton (Incandescent)
ø29mm Mushroom
ø40mm Push-Pull
(Non-marking/Marking)

Shape

Part No.
Page

ALW3, ALW3B,
AOLW3, AOLW3B
17

Knob

Lever

Key

Illuminated Selector
Switch
(LED/Incandescent)
Knob

ASW
21

ASW∗L
22

ASW∗K
23

ASLW
24, 25

Function
Category

AYLW4
AYLW4B
18

Selector Switch

Shape

Part No.
Page

(14/05/22)

3

ø22
    TW
Series Switches & Pilot Lights
General-purpose switches & pilot lights for various applications
Heavy-duty type for high-level protection against
harsh environment

•	Highly reliable HW contact blocks are used.
•	Degree of protection: IP65 (IEC 60529)
•	UL and CSA approved, EN compliant
Applicable Standards

Mark

File No. or Organization

UL508

UL Listing
File No. E68961

CSA C22.2 No.14

CSA File No. LR21451
TÜV Rheinland

EN60947-5-1
EU Low Voltage Directive
CCC
No. 2003010305027380
(pilot light: No. 2007010304226713)

GB14048.5

Specifications and Ratings
Contact Ratings
Contact Block

Rated Insulation Voltage
Rated Continuous Current
Contact Ratings by Utilization Category
IEC 60947-5-1

600V
10A
AC-15 (A600)
DC-13 (P600)

Characteristics
Contact Ratings by Utilization Category
Operational Voltage
AC-12	 Control of resistive loads and solid state loads
AC
Operational 50/60 Hz AC-15	 Control of electromagnetic loads (> 72 VA)
Current
DC-12	 Control of resistive loads and solid state loads
DC
DC-13	 Control of electromagnets

24V
10A
10A
8A
4A

48V
—
—
4A
2A

50V
10A
7A
—
—

110V
10A
5A
2.2A
1.1A

220V
6A
3A
1.1A
0.6A

440V
2A
1A
—
—

Minimum applicable load: 3V AC/DC, 5 mA (applicable range may vary with operating conditions and load types)
For the switches & pilot Lights listed below, the rated current (load switching current) is reduced to a half of the rated operational current of
the contact block. The rated insulation voltage (600V) and the rated thermal current (10A) remain unchanged.
•	Selector switches and illuminated selector switches with contact code 2S, 3S, 4S, 2R, or 4R.

HW-C (Contact Block)
M3.5 terminal screw
2-way wiring possible

Contact Blocks
Double-break rolling
action silver contacts
with raked surface

Snap-fit groove

Fitting groove

Push rod
Color-coded for
different contacts

Contact
NO
NC
NO (early make) NC (late break)
Housing
Blue
Purple red Blue
Purple red
Push Rod Green Red
Black
White

Alkali-resistant
66 nylon housing

Snap-fit latch
A maximum of four contact blocks in two
layers can mount on the operator.

Incandescent Lamp Ratings (LS)
LS-6
LS-8
LS-2
BA9S/13
6V AC/DC
12V AC/DC
18V AC/DC
1W (6.3V)
1W (18V)
1W (24V)
Die stamped on the base
Approx. 1,000 hours minimum
Life (reference value)
(mean value when used on the rated voltage)

Part No.
Lamp Base
Rated Voltage
Wattage
Voltage Marking

4

LS-3
24V AC/DC
1W (30V)

(14/05/22)

TW Series Switches & Pilot Lights ø22
LED Lamp Ratings (LSTD)
Part No.
Lamp Base
Rated Voltage
Voltage Range
AC
DC

Current Draw
Color Code 

Lamp Base Color
Voltage Marking
Life (reference value)

LSTD-6
LSTD-1
LSTD-2
BA9S/13
6V AC/DC
12V AC/DC
24V AC/DC
6V AC/DC ±10%
12V AC/DC ±10%
24V AC/DC ±10%
8 mA
11 mA
11 mA
A, R, W: 7 mA,	
G, PW, S: 5.5 mA
10 mA
10 mA
A (amber), G (green), PW (pure white), R (red), S (blue), W (white)
Use a pure white LED lamp for yellow illumination
Same as illumination color
Die stamped on the base
Approx. 50,000 hours (until the brightness reduces to 50% of the initial value when lit at complete direct
current of the rated voltage under 25ºC environment.)

X1

LED Chip
Protection Diode

Internal Circuit

Zener Diode

X2

Resistor

Specifications
Operating Temperature
Storage Temperature
Operating Humidity
Contact Resistance
Insulation Resistance
Dielectric Strength
Vibration Resistance
Shock Resistance

Mechanical Life (minimum operations)

Electrical Life (minimum operations)

Weight (approx.)

–25 to +50°C (no freezing)
–40 to +80°C
45 to 85% RH (no condensation)
50 mΩ maximum (initial value)
100 MΩ minimum (500V DC megger)
Between live and dead metal parts:	 2,500V AC, 1 minute
	
(Full voltage illuminated units: 2,000V AC, 1 minute)
Damage Limits: 30 Hz, amplitude 1.5 mm
Operating extremes:	 5 to 55 Hz, amplitude 0.5 mm
Damage limits:	
1,000 m/s2
Operating extremes:	    100 m/s2
Pushbuttons, Illuminated pushbuttons
Momentary:	5,000,000
Others:	  500,000
  500,000
Selector switches:	
Illuminated selector switches:	  500,000
  500,000 (switching frequency 1,800 operations/h, duty ratio 40%)
Pushbuttons:	
Illuminated pushbuttons:	
  500,000 (switching frequency 1,800 operations/h, duty ratio 40%)
  500,000 (switching frequency 1,200 operations/h, duty ratio 40%)
Selector switches:	
68g (ABW122)
33g (APW122D)
89g (ALW22222D)
68g (ASW222)
107g (ASW2K22)
90g (ASLW22222D)
95g (APW126D)

Mounting Hole Layout
R0.8 max.

50

+0
.
0 4

(45 min.)

.3

+0.2
0

(Note 1)

24.1 +0.4
0

3.2

ø22

30 (Note 2)

Note 1:	 The 3.2 mm recess is for preventing rotation and is not necessary when the nameplate or antirotation ring is not used.
Note 2:	 The minimum mounting centers are applicable to switches with one layer of contact blocks
(two contact blocks). When two layers of contact blocks are mounted, determine the minimum
mounting centers in consideration of convenience for wiring.
•	ø40mm mushroom: 40 mm minimum
•	2-position, 3-position lever selector switch: 39 mm minimum
•	4-position, 5-position lever selector switch: 50 mm minimum

Degree of Protection
Part No.
A∗∗∗∗

Unit

NEMA ICS 6-110

IEC 60529

Pushbuttons, pilot lights, illuminated pushbuttons, and selector switches

Type 1, 2, 3, 3R, (3S), 4, 5, 12,13 IP65

Illuminated selector switches, key pushbuttons, key reset pushbuttons, and
key selector switches

Type 1, 2, 3R, 5, 12, 13

IP54

Note:	 (3S) of NEMA ICS 6-110 applies to the pilot lights with round lens.
(14/05/22)

5

ø22 TW Series Ordering Information
Ordering Information
•	Specify an operator or lens color code in the Part No.
•	All standard units are UL, CSA, EN, and TÜV approved.

•	When a terminal cover is required, order an applicable
terminal cover referring to page 29.

Part No. development charts shown below can be used to specify switches/pilot lights other than those listed on the following
pages. Gold-plated silver contacts are also available.

Pushbuttons

Illuminated Pushbuttons
ALFW2 126 13 D R - MAU

ABW1 11 R - MAU
Optional contact
MAU: Gold-plated silver contact
Button color code
Contact arrangement code
10:	1NO	
01:	1NC
11:	 1NO-1NC	
20:	2NO
02:	2NC	
21:	2NO-1NC
30:	3NO
12:	 1NO-2NC	
03:	3NC	
31:	3NO-1NC
22:	2NO-2NC	
13:	1NO-3NC
04:	4NC
40:	4NO	

Optional contact
MAU: Gold-plated silver contact
Lens color code
Contact arrangement code
10:	1NO	
01:	1NC
11:	 1NO-1NC	
20:	2NO
02:	2NC	
21:	2NO-1NC
12:	1NO-2NC	
30:	3NO
03:	3NC	
31:	3NO-1NC
22:	2NO-2NC	
13:	1NO-3NC
40:	4NO	
04:	4NC
Operating voltage code

Note:
•	Push-pull type AYW4 can have a maximum of two contact blocks.

Note:
•	Push-pull type AYLW4 can have a maximum of two contact blocks.

Pilot Lights

Selector Switch

APW2 126 D R
Lens color code
Operating voltage code

Key Selector Switch
ASW 2 K 20 B - MAU
Optional contact
MAU:	 Gold-plated silver contact
Key removable position code
2-position
•	Maintained
(blank):	Removable in all positions
B:	
Removable in left only
C:	
Removable in right only
•	Spring return from right
(blank):	Removable in left only
•	Spring return from left
(blank):	Removable in right only
3-position
•	Maintained
(blank):	Removable in all positions
B:	
Removable in left and center
C:	
Removable in right and center
D:	
Removable in center only
E:	
Removable in right and left
G:	
Removable in left only
H:	
Removable in right only
•	Spring return from right
(blank):	Removable in left and center
D:	
Removable in center only
G:	
Removable in left only
•	Spring return from left
(blank):	Removable in right and center
D:	
Removable in center only
H:	
Removable in right only
•	Spring return two-way
(blank):	Removable in center only
Contact arrangement code
Number of positions

ASW 2 L 11 - MAU
Optional contact
MAU: Gold-plated silver contact
Contact arrangement code
Operator type
(blank):	Knob
L:	Lever
Number of positions
Note:
•	See pages 26 to 28 for contact arrangement codes.

Illuminated Selector Switch
ASLW 2 16 22 D R - MAU
Optional contact
MAU: Gold-plated silver contact
Lens color code
Contact arrangement code
Operating voltage code
Number of positions
Note:
•	See pages 26 to 28 for contact arrangement codes.

Note:
•	See pages 26 to 28 for contact arrangement codes.
•	The key cannot be removed in the return position.

6

(14/05/22)

TW Series Pushbuttons ø22
Flush / Extended / Extended w/Full Shroud / Mushroom

Extended with Full Shroud
ABFW2
AOFW2
Momentary

Maintained

ø29mm Mushroom
ABW3
AOW3
Momentary

Maintained

37

ø29

48.5 (1-2 blocks) 13
30

68.5 (3-4 blocks)

Panel Thickness 1 to 6

37

M3.5 Terminal
Screws

48.5 (1-2 blocks) 13

Specify a button
color code in
place of  in the
Part No.
B:	black
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

30

68.5 (3-4 blocks)

19

M3.5 Terminal
Screws

Panel Thickness 1 to 6

37

Maintained

Panel Thickness 1 to 6

48.5 (1-2 blocks) 19.5
30

68.5 (3-4 blocks)

M3.5 Terminal
Screws

Panel Thickness 1 to 6

48.5 (1-2 block)
68.5 (3-4 blocks)

37

Momentary

M3.5 Terminal
Screws

ø29

Extended
ABW2
AOW2

ABW110
ABW101
ABW111
ABW120
ABW102
ABW122
AOW110
AOW101
AOW111
AOW120
AOW102
AOW122
ABW210
ABW201
ABW211
ABW220
ABW202
ABW222
AOW210
AOW201
AOW211
AOW220
AOW202
AOW222
ABFW210
ABFW201
ABFW211
ABFW220
ABFW202
ABFW222
AOFW210
AOFW201
AOFW211
AOFW220
AOFW202
AOFW222
ABW310
ABW301
ABW311
ABW320
ABW302
ABW322
AOW310
AOW301
AOW311
AOW320
AOW302
AOW322

Dimensions (mm)

Code

ø29

Maintained

1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC

 Button Color

ø29

Momentary

Part No.

ø24

Flush
ABW1
AOW1

Contact

ø24

Operation

ø24

Shape

13
22.5

30

•	Round bezel and shroud (metal): Mat aluminum color
•	Pushbuttons with one or three contact blocks contain a dummy block.
•	Other contact arrangements and gold-plated silver contacts are also available. See page 6.

(14/05/22)

7

ø22 TW Series Pushbuttons
Mushroom / Pushlock Turn Reset / Push Turn Lock / Pushlock Key Reset

ø40mm Pushlock Turn Reset
AVW4 (Note)

ø40mm Push Turn Lock
AJW4

2NO

ABGW420

2NC

ABGW402

2NO-2NC

ABGW422

1NO

AVW310

1NC

AVW301

1NO-1NC

AVW311

2NO

AVW320

2NC

AVW302

2NO-2NC

AVW322

1NO

AVW410

1NC

AVW401

1NO-1NC

AVW411

2NO

AVW420

2NC

AVW402

2NO-2NC

AVW422

1NO

AJW410

1NC

AJW401

1NO-1NC

AJW411

2NO

AJW420

2NC

AJW402

2NO-2NC

AJW422

1NO

AXW310R

1NC

AXW301R

1NO-1NC

AXW311R

2NO

AXW320R

2NC

AXW302R

2NO-2NC

AXW322R

37

ø40
Panel Thickness 1 to 6

37

ABGW411

M3.5 Terminal
Screw

48.5 (1-2 blocks)
68.5 (3-4 blocks)

30

23

M3.5 Terminal
Screws

Panel Thickness
1 to 6

Reset Angle 75

48.5 (1-2 blocks) 13

R:	red
Y:	yellow

30

22.5

68.5 (3-4 blocks)

M3.5 Terminal
Screws

Panel Thickness
1 to 6

Reset Angle 75

48.5 (1-2 blocks) 13
68.5 (3-4 blocks)

M3.5 Terminal
Screws

B:	black
G:	green
R:	red
Y:	yellow

30

22.5

Panel Thickness
1 to 6
Reset Angle 75
LO

H

CK

ø29mm Pushlock Key Reset
AXW3 (Note)

1NO-1NC

30

22.5

37

ø29mm Pushlock Turn Reset
AVW3 (Note)

B:	black
G:	green
ABGW410 R:	red
S:	blue
W:	white
ABGW401
Y:	yellow

48.5 (1-2 blocks) 13
68.5 (3-4 blocks)

37

Momentary

Specify a button
color code in
place of  in the
Part No.

37

1NC

Panel Thickness 1 to 6

48.5 (1-2 blocks) 13
68.5 (3-4 blocks)

M3.5 Terminal
Screws

30

22.5

Panel Thickness Reset
1 to 6
(unlock)

Red only

45

37

1NO

M3.5 Terminal
Screws

PU
S

ø40mm Mushroom
w/Full Shroud
ABGW4

Dimensions (mm)

Code

ø29

Maintained

ABW410
ABW401
ABW411
ABW420
ABW402
ABW422
AOW410
AOW401
AOW411
AOW420
AOW402
AOW422

 Button Color

ø46

Momentary

1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC

Part No.

ø29

ø40mm Mushroom
ABW4
AOW4

Contact

ø40

Operation

ø40

Shape

13
48.5 (1-2 blocks)
68.5 (3-4 blocks)

25
47

30

•	Round bezel (metal): Mat aluminum color
•	Pushbuttons with one or three contact blocks contain a dummy block.
•	Other contact arrangements and gold-plated silver contacts are also available. See page 6.
Note:	 AVW3, AVW4, and AXW3 pushbuttons cannot be used as emergency stop switches. When emergency stop switches are required,
use XW or HW series pushbuttons (ISO 13850 and IEC 60947-5-5 compliant).

8

(14/05/22)

TW Series Pushbuttons ø22
Pushlock Key Reset / Push-Pull / Square Flush / Square Extended

2NO

AXW420R

2NC

AXW402R

2NO-2NC

AXW422R

1NO

AYW410

1NC

AYW401

1NO-1NC

AYW411

2NO

AYW420

2NC
Square Flush
ABQW1
AOQW1
Momentary

Maintained

Square Extended
ABQW2
AOQW2
Momentary

Maintained

1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC

Red only

45

13
48.5 (1-2 blocks)

25

68.5 (3-4 blocks)

M3.5 Terminal
Screws

30

47

Panel Thickness
1 to 6

13

48.5 (1-2 blocks)
68.5 (3-4 blocks)

AYW402
ABQW110
ABQW101
ABQW111
ABQW120
ABQW102
ABQW122
AOQW110
AOQW101
AOQW111
AOQW120
AOQW102
AOQW122
ABQW210
ABQW201
ABQW211
ABQW220
ABQW202
ABQW222
AOQW210
AOQW201
AOQW211
AOQW220
AOQW202
AOQW222

Reset
(unlock)

37

AXW411R

Panel Thickness
1 to 6

37

1NO-1NC

M3.5 Terminal
Screws

Specify a button
color code in
place of  in the
Part No.
B:	black
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

M3.5 Terminal
Screws

25
30

30.5

Panel Thickness
1 to 6

37

AXW401R

48.5 (1-2 blocks) 13
30

68.5 (3-4 blocks)

M3.5 Terminal
Screws

Panel Thickness
1 to 6

37

1NC

ø40

AXW410R

Dimensions (mm)

Code

ø40

1NO

 Button Color

25

ø40mm Mushroom Push-Pull
AYW4

Part No.

30

ø40mm Mushroom Push Lock Key Reset
AXW4 (Note)

Contact

30

Operation

25

Shape

48.5 (1-2 blocks) 13
68.5 (3-4 blocks)

20

30

•	Round bezel (metal): Mat aluminum color
•	Square bezel (plastic): Black
•	Pushbuttons with one or three contact blocks contain a dummy block.
•	Other contact arrangements and gold-plated silver contacts are also available. See page 6.
Note:	 AXW4 pushbuttons cannot be used as emergency stop switches. When emergency stop switches are required, use XW or HW
series pushbuttons (ISO 13850 and IEC 60947-5-5 compliant).

Contact Statuses of Push-Pull Switch
Contact

ø40mm Mushroom
Push-Pull Switch
Push
Pull

1NO
1NC
1NO-1NC
2NO
2NC
Note:	 Push-pull switch can have a maximum of two contact blocks.

(14/05/22)

9

ø22 TW Series Pilot Lights
Round Flush / Dome / Square Flush Pilot Lights
Shape

Lamp

Round Flush
APW1

Round Flush (Marking)
APW1B

Dome
APW2

Square Flush (Marking)
APQW1B

Part No.

Package Quantity: 1
 Lens/Illumination Color Code

Without Lamp

APW199

A: amber, G: green, R: red, S: blue, W: white,
Y: yellow

LED

APW1D

A: amber, G: green, PW: pure white, R: red,
S: blue, W: white, Y: yellow

Incandescent

APW1

A: amber, G: green, R: red, S: blue, W: white

Without Lamp

APW1B99

A: amber, G: green, R: red, S: blue, W: white,
Y: yellow

LED

APW1BD

A: amber, G: green, PW: pure white, R: red,
S: blue, W: white, Y: yellow

Incandescent

APW1B

A: amber, G: green, R: red, S: blue, W: white

Without Lamp

APW299

A: amber, G: green, R: red, S: blue, W: white,
Y: yellow

LED

APW2D

A: amber, G: green, PW: pure white, R: red,
S: blue, W: white, Y: yellow

Incandescent

APW2

A: amber, G: green, R: red, S: blue, W: white

Without Lamp

APQW1B99

A: amber, G: green, R: red, S: blue, W: white,
Y: yellow

LED

APQW1BD

A: amber, G: green, PW: pure white, R: red,
S: blue, W: white, Y: yellow

Incandescent

APQW1B

A: amber, G: green, R: red, S: blue, W: white

Designation Code
Specify an designation code in place of  in the Part No.

 Operating Voltage Code
LED

Incandescent

66: 	
6V AC/DC
11:	
12V AC/DC
22:	
24V AC/DC
16:	
100/110V AC
126:	
115/120V AC
26:	
200/220V AC
246:	
230/240V AC
386:	
380V AC
46:	
400/440V AC
486:	
480V AC
16D: 110V DC

66:	
88:	
33:	

Input Type

6V AC/DC
12V AC/DC
24V AC/DC

Full Voltage

Transformer

—

DC-DC Converter *

•	Use a pure white LED lamp for yellow illumination.
•	The white (W) lens of APW1B and APQW1B consists of a clear lens and a white marking plate.
•	Round bezel (metal): Mat aluminum color Square bezel (plastic): Black
∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).

10

(14/05/22)

TW Series Pilot Lights ø22
Dimensions
Round Flush APW1
Transformer, DC-DC Converter

28.5

30

Round Flush Marking APW1B
Transformer, DC-DC Converter

28.5
66.5

Marking plate: ø15.5 mm

Marking plate: ø15.5 mm

13

30

28.5
66.5

30

25

Dome APW2
Transformer, DC-DC Converter
M3.5 Terminal
Screw

13

25
28.5

30

16

Panel Thickness 1 to 6

37

30

25

Panel Thickness
1 to 6

Marking plate:

66.5

22 mm

13
16

37

Dome APW2
Full Voltage

13

37

ø23.6

37

ø29

ø23.6

Panel Thickness
1 to 6

M3.5 Terminal
Screw

25

28.5

30

17

Dome APW2
Transformer, DC-DC Converter

Panel Thickness
1 to 6

28.5

13

ø29

Dome APW2
Full Voltage

37

ø24

37

30

17

Panel Thickness
1 to 6

M3.5 Terminal
Screw

ø29

ø24

Panel Thickness
1 to 6

13

30

17

ø29

Round Flush Marking APW1B
Full Voltage

28.5

13

66.5

17

37

ø24

37

13

30

28.5

Panel Thickness
1 to 6

M3.5 Terminal Screw

ø29

ø24

Panel Thickness
1 to 6

ø29

Round Flush APW1
Full Voltage

30
Marking plate:

22 mm

Terminal Wiring (Bottom View)
•	Arrows indicate access directions for wiring.
TOP

TOP
M3.5

X1

M3.5
X1
X2

X2

Full Voltage

(14/05/22)

Transformer
DC-DC Converter

11

ø22 TW Series Illuminated Pushbuttons
Round Extended Illuminated Pushbuttons
Shape
Round Extended
ALW2
AOLW2

Operation

Lamp

Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC

Without Lamp

Momentary

2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC

LED

Incandescent

2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC

Without Lamp

Maintained

LED

Incandescent

2NO
2NO-2NC

Part No.
ALW29911
ALW29920
ALW29922
ALW211D
ALW220D
ALW222D
ALW21611DD
ALW21620DD
ALW21622DD
ALW211
ALW220
ALW222

(Note)
(Note)
(Note)

AOLW29911
AOLW29920
AOLW29922
AOLW211D
AOLW220D
AOLW222D
AOLW21611DD
AOLW21620DD
AOLW21622DD
AOLW211
AOLW220
AOLW222

(Note)
(Note)
(Note)

Note: DC-DC converter types.

Designation Code
Specify a designation code in place of  or  in the Part No.
 Lens/Illumination Color Code
Without Lamp

LED

Incandescent

 Operating Voltage Code
LED
Incandescent
66: 	 6V AC/DC

A:	amber
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
PW:	pure white
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
R:	red
S:	blue
W:	white

Input Type

66:	 6V AC/DC

11:	 12V AC/DC

88:	 12V AC/DC

22:	 24V AC/DC

33:	 24V AC/DC

Full Voltage

16:	 100/110V AC
126:	 115/120V AC
26:	 200/220V AC
246:	 230/240V AC

Transformer

386:	 380V AC
46:	 400/440V AC
486:	 480V AC
16D: 110V DC

—

DC-DC Converter *

•	Use a pure white LED lamp for yellow illumination.
*DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).

12

(14/05/22)

TW Series Illuminated Pushbuttons ø22
Round Extended Illuminated Pushbuttons (Marking)
Shape
Round Extended (Marking)
ALW2B
AOLW2B

Operation

Lamp

Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC

Without Lamp

Momentary

Part No.
ALW2B9911
ALW2B9920
ALW2B9922
ALW2B11D
ALW2B20D
ALW2B22D

2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC

LED

Incandescent

2NO
2NO-2NC
1NO-1NC

Without Lamp

2NO
2NO-2NC

ALW2B1611DD
ALW2B1620DD
ALW2B1622DD
ALW2B11
ALW2B20
ALW2B22
AOLW2B9911
AOLW2B9920
AOLW2B9922
AOLW2B11D
AOLW2B20D
AOLW2B22D

1NO-1NC
2NO
Maintained

2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC

LED

Incandescent

(Note)
(Note)
(Note)

AOLW2B1611DD
AOLW2B1620DD
AOLW2B1622DD
AOLW2B11
AOLW2B20
AOLW2B22

2NO
2NO-2NC

(Note)
(Note)
(Note)

Note: DC-DC converter types.

Designation Code
Specify a designation code in place of  or  in the Part No.
 Lens/Illumination Color Code
Without Lamp

A:	amber
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

LED

A:	amber
G:	green
PW:	 pure white
R:	red
S:	blue
W:	white
Y:	yellow

Incandescent

A:	amber
G:	green
R:	red
S:	blue
W:	white

 Operating Voltage Code
LED

66: 	 6V AC/DC
11:	 12V AC/DC
22:	 24V AC/DC
16:	 100/110V AC
126:	 115/120V AC
26:	 200/220V AC
246:	 230/240V AC
386:	 380V AC
46:	 400/440V AC
486:	 480V AC
16D: 110V DC

Incandescent

66:	6V AC/DC
88:	12V AC/DC
33:	24V AC/DC

Input Type
Full Voltage

Transformer

—

DC-DC Converter *

•	Use a pure white LED lamp for yellow illumination.
*DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).

(14/05/22)

13

ø22 TW Series Illuminated Pushbuttons
Round Extended with Full Shroud Illuminated Pushbuttons
Shape
Round Extended
With Full Shroud
ALFW2
AOLFW2

Operation

Lamp
Without Lamp

Momentary

LED

Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC

Incandescent

2NO
2NO-2NC
1NO-1NC

Without Lamp

2NO
2NO-2NC
1NO-1NC
2NO

Maintained

LED

Incandescent

2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC

Part No.
ALFW29911
ALFW29920
ALFW29922
ALFW211D
ALFW220D
ALFW222D
ALFW21611DD
ALFW21620DD
ALFW21622DD
ALFW211
ALFW220
ALFW222

(Note)
(Note)
(Note)

AOLFW29911
AOLFW29920
AOLFW29922
AOLFW211D
AOLFW220D
AOLFW222D
AOLFW21611DD
AOLFW21620DD
AOLFW21622DD
AOLFW211
AOLFW220
AOLFW222

(Note)
(Note)
(Note)

Note: DC-DC converter types.

Designation Code
Specify a designation code in place of  or  in the Part No.
 Lens/Illumination Color Code
Without Lamp
LED
Incandescent

A:	amber
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
PW:	 pure white
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
R:	red
S:	blue
W:	white

 Operating Voltage Code
LED
Incandescent
66:	6V AC/DC
66: 	 6V AC/DC
11:	 12V AC/DC
88:	12V AC/DC
22:	 24V AC/DC
33:	24V AC/DC
16:	 100/110V AC
126:	 115/120V AC
26:	 200/220V AC
246:	 230/240V AC
386:	 380V AC
46:	 400/440V AC
486:	 480V AC
16D: 110V DC
—

Input Type
Full Voltage

Transformer

DC-DC Converter *

•	Use a pure white LED lamp for yellow illumination.
∗DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).

14

(14/05/22)

TW Series Illuminated Pushbuttons ø22
Round Extended with Full Shroud Illuminated Pushbuttons (Marking)
Shape
Round Extended (Marking)
With Full Shroud
ALFW2B
AOLFW2B

Operation

Lamp
Without Lamp

Momentary

LED

2NO
2NO-2NC
1NO-1NC

ALFW2B9920
ALFW2B9922
ALFW2B11D
ALFW2B20D
ALFW2B22D

2NO

Without Lamp

LED

Part No.
ALFW2B9911

2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC

Incandescent

Maintained

Contact
1NO-1NC

ALFW2B22
AOLFW2B9911

2NO
2NO-2NC
1NO-1NC

AOLFW2B9920
AOLFW2B9922
AOLFW2B11D
AOLFW2B20D
AOLFW2B22D

2NO
2NO-2NC
1NO-1NC

(Note)
(Note)
(Note)

ALFW2B20

2NO-2NC
1NO-1NC

AOLFW2B1611DD

(Note)

AOLFW2B1620DD

(Note)

2NO-2NC

AOLFW2B1622DD

(Note)

1NO-1NC
2NO
2NO-2NC

AOLFW2B11
AOLFW2B20
AOLFW2B22

2NO

Incandescent

ALFW2B1611DD
ALFW2B1620DD
ALFW2B1622DD
ALFW2B11

Note: DC-DC converter types.

Designation Code
Specify a designation code in place of  or  in the Part No.

 Lens/Illumination Color Code
Without Lamp

A:	amber
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

LED

A:	amber
G:	green
PW:	 pure white
R:	red
S:	blue
W:	white
Y:	yellow

Incandescent

A:	amber
G:	green
R:	red
S:	blue
W:	white

 Operating Voltage Code
LED
Incandescent
66: 	 6V AC/DC
66:	6V AC/DC
11:	 12V AC/DC
88:	12V AC/DC
33:	24V AC/DC
22:	 24V AC/DC
16:	 100/110V AC
126:	115/120V AC
26:	 200/220V AC
246:	230/240V AC
386:	380V AC
46:	 400/440V AC
486:	480V AC
16D: 110V DC
—

Input Type
Full Voltage

Transformer

DC-DC Converter ∗

•	Use a pure white LED lamp for yellow illumination.
∗DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).

(14/05/22)

15

ø22 TW Series Illuminated Pushbuttons
Square Extended Illuminated Pushbuttons (Marking)
Shape
Square Extended (Marking)
ALQW2B
AOLQW2B

Operation

Lamp
Without Lamp

Momentary

Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC

LED

Incandescent

2NO
2NO-2NC
1NO-1NC

Without Lamp

2NO
2NO-2NC
1NO-1NC
2NO

Maintained

LED

Incandescent

2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC

Part No.
ALQW2B9911
ALQW2B9920
ALQW2B9922
ALQW2B11D
ALQW2B20D
ALQW2B22D
ALQW2B1611DD
ALQW2B1620DD
ALQW2B1622DD
ALQW2B11
ALQW2B20
ALQW2B22

(Note)
(Note)
(Note)

AOLQW2B9911
AOLQW2B9920
AOLQW2B9922
AOLQW2B11D
AOLQW2B20D
AOLQW2B22D
AOLQW2B1611DD
AOLQW2B1620DD
AOLQW2B1622DD
AOLQW2B11
AOLQW2B20
AOLQW2B22

(Note)
(Note)
(Note)

Note: DC-DC converter types.

Designation Code
Specify a designation code in place of  or  in the Part No.
 Lens/Illumination Color Code
Without Lamp
LED
Incandescent

A:	amber
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
PW:	 pure white
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
R:	red
S:	blue
W:	white

 Operating Voltage Code
LED
Incandescent
66: 	 6V AC/DC
66:	6V AC/DC
11:	 12V AC/DC
88:	12V AC/DC
33:	24V AC/DC
22:	 24V AC/DC
16:	 100/110V AC
126:	115/120V AC
26:	 200/220V AC
246:	230/240V AC
386:	380V AC
46:	 400/440V AC
486:	480V AC
16D: 110V DC
—

Input Type
Full Voltage

Transformer

DC-DC Converter *

•	Use a pure white LED lamp for yellow illumination.
*DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).

16

(14/05/22)

TW Series Illuminated Pushbuttons ø22
Mushroom (ø29) Illuminated Pushbuttons
Shape
ø29 Mushroom
ALW3
AOLW3

Operation

Lamp

Contact

Part No.

Without Lamp

ALW39911

Incandescent

ALW311

Without Lamp

AOLW39911

Momentary

Maintained
AOLW311

Incandescent
1NO-1NC

ø29 Mushroom (Marking)
ALW3B
AOLW3B

Without Lamp

ALW3B9911

Incandescent

ALW3B11

Without Lamp

AOLW3B9911

Incandescent

AOLW3B11

Momentary

Maintained
ø29 Mushroom Pushlock Turn Reset
AVLW3

Without Lamp

LED

Incandescent
(Note)
ø29 Mushroom Pushlock Turn Reset (Marking)
AVLW3B

Without Lamp

LED

Incandescent
(Note)

1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO

AVLW39911R
AVLW39920R
AVLW39922R
AVLW311DR
AVLW320DR
AVLW322DR
AVLW311R
AVLW320R

2NO-2NC

AVLW322R

1NO
1NC
1NO-1NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO

AVLW3B9911R
AVLW3B9920R
AVLW3B9922R
AVLW3B11DR
AVLW3B20DR
AVLW3B22DR
AVLW3B11R
AVLW3B20R

2NO-2NC

AVLW3B22R

Designation Code
Specify a designation code in place of  or  in the Part No.
Without Lamp
A:	amber
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

 Lens/Illumination Color Code
LED
Incandescent
A:	amber
G:	green
PW:	 pure white
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
R:	red
S:	blue
W:	white

 Operating Voltage Code
LED
Incandescent
66:	6V AC/DC
66: 	 6V AC/DC
11:	 12V AC/DC
88:	12V AC/DC
22:	 24V AC/DC
33:	24V AC/DC
16:	 100/110V AC
126:	115/120V AC
26:	 200/220V AC
246:	230/240V AC
386:	380V AC
46:	 400/440V AC
486:	480V AC

Input Type
Full Voltage

Transformer

•	Use a pure white LED lamp for yellow illumination.
Note:	 TW series pushlock turn reset illuminated pushbuttons cannot be used as emergency stop switches under international safety
standards ISO13850 and IEC60947-5. For use as emergency stop switches, use XW or HW series.

(14/05/22)

17

ø22 TW Series Illuminated Pushbuttons
Mushroom (ø40 mm) Illuminated Pushbuttons
Shape
ø40 Mushroom Pushlock Turn Reset
AVLW4

ø40 Mushroom Pushlock Turn Reset (Marking)
AVLW4B

ø40 Mushroom Push Pull
AYLW4
(2-position
maintained)

Lamp
Without Lamp

Full Voltage

LED

Transformer

Incandescent

Transformer

Without Lamp

Full Voltage

LED

Transformer

Incandescent

Transformer

Without Lamp

Incandescent
ø40 Mushroom Push Pull (Marking)
AYLW4B
(2-position
maintained)

Input Type

Without Lamp

Incandescent

Full Voltage

Transformer

Full Voltage

Transformer

Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO
1NC
1NO-1NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC

Part No.
AVLW49911R
AVLW49920R
AVLW49922R
AVLW411DR
AVLW420DR
AVLW422DR
AVLW411R
AVLW420R
AVLW422R
AVLW4B9911R
AVLW4B9920R
AVLW4B9922R
AVLW4B11DR
AVLW4B20DR
AVLW4B22DR
AVLW4B11R
AVLW4B20R
AVLW4B22R

1NO-1NC

AYLW49911

2NO

AYLW49920

2NO-2NC

AYLW49922

1NO-1NC

AYLW411

2NO

AYLW420

1NO

AYLW4B9911

1NC

AYLW4B9920

1NO-1NC

AYLW4B9922

1NO-1NC

AYLW4B11

2NO

AYLW4B20

Designation Code
Specify a designation code in place of  or  in the Part No.
Without Lamp
A:	amber
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

 Lens/Illumination Color Code
LED
Incandescent
A:	amber
G:	green
PW:	 pure white
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
R:	red
S:	blue
W:	white

 Operating Voltage Code
LED
Incandescent
66:	6V AC/DC
66: 	 6V AC/DC
11:	 12V AC/DC
88:	12V AC/DC
22:	 24V AC/DC
33:	24V AC/DC
16:	 100/110V AC
126:	 115/120V AC
26:	 200/220V AC
246:	 230/240V AC
386:	 380V AC
46:	 400/440V AC
486:	 480V AC

Input Type
Full Voltage

Transformer

•	Use a pure white LED lamp for yellow illumination.
Note:	 TW series pushlock turn reset illuminated pushbuttons cannot be used as emergency stop switches under international safety
standards ISO13850 and IEC60947-5. For use as emergency stop switches, use XW or HW series.

Contact Statuses of Push-Pull Switch
Contact

ø40mm Mushroom Push-Pull Switch
Push
Pull

1NO
1NC
1NO-1NC
2NO
2NC

Note: Push-pull switch can have a maximum of two contact blocks.

18

(14/05/22)

TW Series Illuminated Pushbuttons ø22
Dimensions (Operator)

Panel Thickness
1 to 6

37

ø24

ø29

37

25

Panel Thickness
1 to 6

ø29

ø24

Panel Thickness
1 to 6

Square Extended (marking)
ALQW2B / AOLQW2B

37

Round Extended with Full Shroud
(non-marking/marking)
ALFW2 / ALFW2B / AOLFW2 / AOLFW2B

30

Round Extended (non-marking/marking)
ALW2 / ALW2B / AOLW2 / AOLW2B

13

13
30

19

20

Marking plate:

Marking plate: ø15.5mm

21mm

Marking plate: ø15.5mm

ø29 Mushroom (non-marking/marking)
ALW3 / ALW3B / AOLW3 / AOLW3B

ø29 Mushroom Pushlock Turn Reset
(non-marking/marking)
AVLW3 / AVLW3B

Panel Thickness
1 to 6

Panel Thickness
1 to 6

ø40 Mushroom Pushlock Turn Reset
(non-marking/marking)
AVLW4 / AVLW4B
Panel Thickness
1 to 6

Reset Angle: 75°

Reset Angle 75°

13

30

13

22.5

30

22.5

Marking plate: ø13.9mm

Marking plate: ø13.9mm

37

ø40

37

ø29

37

ø29

30

20

30

13
22.5

30
Marking plate: ø13.9mm

ø40 Mushroom Push Pull
(non-marking/marking)
AYLW4 / AYLW4B

37

ø40

Panel Thickness
1 to 6

13
25
30.5

30

All dimensions in mm.

Marking plate: ø13.9mm

Terminal Arrangement (Lamp Terminal) (Bottom View)
•	Arrows indicate access directions for wiring.
TOP

X1

TOP

X1

TOP

X1
X2

X2

Full Voltage
When using TW-DA1B
Full Voltage Adapter for 2
or 4 contact blocks

(14/05/22)

X2

Full Voltage
When using HW-DA1B
Full Voltage Adapter for
1 or 3 contact blocks

Transformer
DC-DC Converter

19

ø22 TW Series Illuminated Pushbuttons
Dimensions
Transformer
DC-DC Converter

Full Voltage

M3.5
Terminal Screws

Panel Thickness
1 to 6

M3.5 Terminal Screws

Panel Thickness
1 to 6

X1

X1

X2

X2

1 contact
block

48.5

When using HW-DA1B full-voltage adapter

M3.5
Terminal Screws

2 contact
blocks

Panel Thickness
1 to 6

86.5

M3.5 Terminal Screws

Panel Thickness
1 to 6

X1

X2

X1
X2

2 contact
blocks

4 contact
blocks

63.5

106.5

When using TW-DA1B full-voltage adapter

Panel Thickness
1 to 6

X2

X1

M3.5
Terminal Screws

3 contact
blocks

68.5

When using HW-DA1B full-voltage adapter

M3.5 Terminal Screws

Panel Thickness
1 to 6

X1
X2

4 contact
blocks

83.5

When using TW-DA1B full-voltage adapter

Note:	 For push-pull units a maximum of two contact blocks can be used.

All dimensions in mm.

Contact Configuration and Codes
Contact Configuration
1NO
1 block
1NC
1NO-1NC
2 blocks
2NO
2NC
2NO-1NC
1NO-2NC
3 blocks
3NO
3NC
3NO-1NC
2NO-2NC
4 blocks
1NO-3NC
4NO
4NC

20

Code
10
01
11
20
02
21
12
30
03
31
22
13
40
04

(14/05/22)

TW Series Selector Switches ø22

10
11

90° 2-position

Panel Thickness 1 to 6

(1NO-1NC)

20

(2NO)

22
(2NO-2NC)

Contact
Code
20

(2NO)

02

(2NC)

22
(2NO-2NC)

40
(4NO)

04
(4NC)

3S 

Contact
Code

4S 

4S 

3S 

4S 

Contact Block

Operator Position

Mounting
Position

L

1
2
1
2
1
2
1
2
3
4

Maintained
L

Contact

NO

Contact Block

R

R

1
2
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

ASW2110

ASW2210 ∗

ASW211

ASW2111

ASW2211 ∗





ASW220

ASW2120

ASW2220 ∗

ASW222

ASW2122

ASW2222 ∗




1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

37

—

R

L

ASW210



—



Operator Position

Maintained
L

Contact

L

NO
NO
NC
NC
NO
NO
NC
NC
NO
NO
NO
NO
NC
NC
NC
NC
NO
NO
NC



C

R

R

Spring Return
from Right
C

R

L

Spring Return
from Left

Spring Return
Two-way

C

C

R

L

R

L

ASW320

ASW3120

ASW3220

ASW3320

ASW302

ASW3102

ASW3202

ASW3302



ASW322

ASW3122

ASW3222

ASW3322



ASW340

ASW3140

ASW3240

ASW3340

ASW304

ASW3104

ASW3204

ASW3304












—

ASW33S-243 



—

—

Dummy

Contact Block
Mounting
Position

R

L

30

25

Spring Return
from Left



C

Mounting
Position

Spring Return
from Right



Dummy

NO
NC
NO
NO
NO
NC
NO
NC

13

68.5 (4 blocks)

Contact Arrangement Chart

(1NO)

45° 3-position

M3.5 Terminal
Screws

48.5 (2 blocks)

Contact
Code

30° 5-position / 45° 4-position

ASW

ø29

Shape

ø24

No. of Positions

Selector Switches (Knob Operator)

Operator Position

Maintained

Contact

NC
NC
NC
NO
NO
NC
NC
NO
NO
NC
NC

1

2

3

4

2

3

5



3

1

4
5

Left

—






ASW44S-411 

—

ASW43S-461 

—






Dummy

NO
NC
NC
NO




—



Contact Block Mounting Position
and Contact Arrangement Chart

4

ASW44S-407 



Maintained

2
1

1
2
3
4

Center

L
NO 
NO
NC
NC

•	For more contact
arrangement chart,
see pages 26 to 28.

ASW54S-501 

C

Right
Operator
Position

R


4

3

2

TOP

1



•	On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows.

•	On the contact arrangement marked with  in the table above, the rated current (load switching current) is reduced to a half of the rated
current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged.
•	Selector switches with one or three contact blocks contain a dummy block.
•	Knob operator: White indicator on black knob

(14/05/22)

21

ø22 TW Series Selector Switches
Selector Switches (Lever Operator)

11

90° 2-position

37
ø25

10

(1NO-1NC)

20

(2NO)

22
(2NO-2NC)

Contact
Code
20

(2NO)

02

(2NC)

22
(2NO-2NC)

40
(4NO)

04
(4NC)

3S 

Contact
Code

4S 

4S 

3S 

4S 

Contact Block Operator Position

Maintained
L

Mounting
Position

1
2
1
2
1
2
1
2
3
4

Contact

L

NO

R

ASW21L10

ASW22L10 ∗

ASW2L11

ASW21L11

ASW22L11 ∗





ASW2L20

ASW21L20

ASW22L20 ∗

ASW2L22

ASW21L22

ASW22L22 ∗






—



Maintained
C
R

Contact

L

NO
NO
NC
NC
NO
NO
NC
NC
NO
NO
NO
NO
NC
NC
NC
NC
NO
NO
NC



C R

Spring Return
from Right
C

R

L

Spring Return
from Left

Spring Return
Two-way

C

C

R

L

R

L

ASW3L20

ASW31L20

ASW32L20

ASW33L20

ASW3L02

ASW31L02

ASW32L02

ASW33L02



ASW3L22

ASW31L22

ASW32L22

ASW33L22



ASW3L40

ASW31L40

ASW32L40

ASW33L40

ASW3L04

ASW31L04

ASW32L04

ASW33L04

—

—

—












ASW3L3S-243 



Dummy

Maintained

Contact

NC
NC
NC
NO
NO
NC
NC
NO
NO
NC
NC

1

2

3

4

2

3

5



3

1

4
5

Left

—





ASW4L4S-411 



—





ASW4L3S-461 



—

Dummy

NO
NC
NC
NO

Contact Block Mounting Position
and Contact Arrangement Chart

4

ASW4L4S-407 



Maintained

2
1

1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

—

R

L

ASW2L10

Contact Block Operator Position
Mounting
Position

Spring Return
from Left



L

1
2
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

R

30

25



Contact Block Operator Position
Mounting
Position

Spring Return
from Right
L

R

Dummy

NO
NC
NO
NO
NO
NC
NO
NC

13

68.5 (4 blocks)

Contact Arrangement Chart

(1NO)

45° 3-position

Panel Thickness 1 to 6

48.5 (2 blocks)

Contact
Code

30° 5-position / 45° 4-position

M3.5 Terminal
Screws

ASW∗L

ø29

No. of Positions

Shape

1
2
3
4

Center

L
NO 
NO
NC
NC

C

Right



4

•	For more contact
arrangement chart,
see pages 26 to 28.



3



—



Operator
Position

R

ASW5L4S-501 

2

TOP

1



•	On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows.

•	On the contact arrangement marked with  in the table above, the rated current (load switching current) is reduced to a half of the rated
current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged.
•	Selector switches with one or three contact blocks contain a dummy block.
•	Lever operator: White indicator on black lever

22

(14/05/22)

TW Series Selector Switches ø22
Key Selector Switches

Contact Arrangement Chart

Mounting
Position

1
2
1
2
1
2
1
2
3
4

10
11

(1NO-1NC)

20

(2NO)

22

(2NO-2NC)

Contact
Code

Maintained

Contact

L

NO

L

R

1
2
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

20

(2NO)

02

(2NC)

22

(2NO-2NC)

40

(4NO)

04

(4NC)

3S 

Spring Return
from Left

ASW2K10

ASW21K10

ASW22K10 ∗

ASW2K11

ASW21K11

ASW22K11 ∗





ASW2K20

ASW21K20

ASW22K20 ∗

ASW2K22

ASW21K22

ASW22K22 ∗






—

R

L



—



Maintained

Contact Block Operator Position
Mounting
Position

R

L

R

30

41



Dummy

NO
NC
NO
NO
NO
NC
NO
NC

Spring Return
from Right

37

13
19

68.5 (4 blocks)

Contact Block Operator Position

(1NO)

90° 2-position

Panel Thickness 1 to 6

48.5 (2 blocks)

Contact
Code

45° 3-position

M3.5 Terminal
Screws

ø29

ASW∗K

ø24

No. of Positions

Shape

Contact

L

NO
NO
NC
NC
NO
NO
NC
NC
NO
NO
NO
NO
NC
NC
NC
NC
NO
NO
NC



L

C R

C

Spring Return
from CRight

R

R

L

Spring Return
fromC Left
R

L

Spring Return
Two-way
C
R

L

ASW3K20

ASW31K20

ASW32K20

ASW33K20

ASW3K02

ASW31K02

ASW32K02

ASW33K02



ASW3K22

ASW31K22

ASW32K22

ASW33K22



ASW3K40

ASW31K40

ASW32K40

ASW33K40

ASW3K04

ASW31K04

ASW32K04

ASW33K04

—

—

—












ASW3K3S-243 



Dummy

•	On the spring-returned types, the key can be released only from the maintained position. On the maintained types, the key can be released from every position. Key retained positions are also available. See page 6.
•	On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows.

•	On the contact arrangement marked with  in the table above, the rated current (load switching current) is reduced to a half of the rated
current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged.
•	Key selector switches with one or three contact blocks contain a dummy block.
•	Cylinder cover: Black, Cylinder: Metal

Contact Block Mounting Position and Contact Arrangement Chart
4

3

1

2

Left

Center

Right

TOP

1
2
3
4

L
NO 
NO
NC
NC

C

R

Operator
Position



•	For more contact arrangement chart, see pages 26 to 28.

(14/05/22)

23

ø22 TW Series Illuminated Selector Switches
Illuminated Selector Switches
90° 2-position
M3.5 Terminal Screws

Panel Thickness 1 to 6

A: 63.5 (2 blocks)
83.5 (4 blocks)
B: 86.5 (2 blocks), 106.5 (4 blocks)

Contact Arrangement Chart
Contact
Code

Contact
Block
Mounting
Contact
Position

11
(1NO-1NC)

20
(2NO)

1

NO

2

NC

22

L

Lamp

L

R

30

25

A: Rated voltage 24V AC/DC
B: Rated voltage 100/110V AC, 200/220V AC

Spring Return
from Right
L

37

13

R

Spring Return
from Left
L

R

R




Without Lamp

ASLW29911

ASLW219911

ASLW229911

LED

ASLW211D

ASLW2111D

ASLW2211D

Incandescent

ASLW211

ASLW2111

ASLW2211

1

NO



Without Lamp

ASLW29920

ASLW219920

ASLW229920

2

NO



LED

ASLW220D

ASLW2120D

ASLW2220D

Incandescent

ASLW220

ASLW2120

ASLW2220

Without Lamp

ASLW29922

ASLW219922

ASLW229922

LED

ASLW222D

ASLW2122D

ASLW2222D

Incandescent

ASLW222

ASLW2122

ASLW2222

1
2
3
4

(2NO-2NC)

Maintained

Operator
Position

ø29

ASLW

ø24

Shape

NO
NC
NO
NC






Designation Code
Specify a designation code in place of  or  in the Part No.
Without Lamp

 Lens/Illumination Color Code
LED
Incandescent

A:	amber
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
PW:	 pure white
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
R:	red
S:	blue
W:	white

 Operating Voltage Code
LED
Incandescent
66:	6V AC/DC
66: 	 6V AC/DC
11:	 12V AC/DC
88:	12V AC/DC
22:	 24V AC/DC
33:	24V AC/DC
16:	 100/110V AC
136:	115/120V AC
26:	 200/220V AC
256:	230/240V AC
386:	380V AC
46:	 400/440V AC
486:	480V AC

Input Type
Full Voltage

Transformer

Contact Block Mounting Position and Contact Arrangement Chart
4

2

Left

TOP

Right

L
3

1

1
2
3
4

NO
NC
NO
NC

R


Operator
Position





•	For more contact arrangement chart, see pages 26 to 28.

24

(14/05/22)

TW Series Illuminated Selector Switches ø22
Illuminated Selector Switches
45° 3-position
Contact
Block

Contact
Code

Mounting
Contact
Position

20

(2NO)

02

(2NC)

22
(2NO-2NC)

1

NO

2

NO

40

04

C

L

C

R

L

R




R

Spring Return
from left
C

L

R

Spring Return
Two-way
C

L

R

Without Lamp

ASLW39920

ASLW319920

ASLW329920

ASLW339920

LED

ASLW320D

ASLW3120D

ASLW3220D

ASLW3320D

Incandescent

ASLW320

ASLW3120

ASLW3220

ASLW3320

NC

Without Lamp

ASLW39902

ASLW319902

ASLW329902

ASLW339902

2

NC

LED

ASLW302D

ASLW3102D

ASLW3202D

ASLW3302D

Incandescent

ASLW302

ASLW3102

ASLW3202

ASLW3302

1
2
3
4

NO
NO
NC
NC

Without Lamp

ASLW39922

ASLW319922

ASLW329922

ASLW339922

LED

ASLW322D

ASLW3122D

ASLW3222D

ASLW3322D

Incandescent

ASLW322

ASLW3122

ASLW3222

ASLW3322

Without Lamp

ASLW39940

ASLW319940

ASLW329940

ASLW339940

LED

ASLW340D

ASLW3140D

ASLW3240D

ASLW3340D

Incandescent

ASLW340

ASLW3140

ASLW3240

ASLW3340

Without Lamp

ASLW39904

ASLW319904

ASLW329904

ASLW339904

LED

ASLW304D

ASLW3104D

ASLW3204D

ASLW3304D

Incandescent

ASLW304

ASLW3104

ASLW3204

ASLW3304

NO
NO
NO
NO

1
2
3
4

(4NC)

L

Lamp

Spring Return
from Right

C

1

1
2
3
4

(4NO)

Maintained

Operator
Position









NC
NC
NC
NC

Designation Code
Specify a designation code in place of  or  in the Part No.
Without Lamp

 Lens/Illumination Color Code
LED
Incandescent

A:	amber
G:	green
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
PW:	 pure white
R:	red
S:	blue
W:	white
Y:	yellow

A:	amber
G:	green
R:	red
S:	blue
W:	white

 Operating Voltage Code
LED
Incandescent
66:	 6V AC/DC
66: 	 6V AC/DC
11:	 12V AC/DC
88:	 12V AC/DC
22:	 24V AC/DC
33:	 24V AC/DC
16:	 100/110V AC
136:	 115/120V AC
26:	 200/220V AC
256:	 230/240V AC
386:	 380V AC
46:	 400/440V AC
486:	 480V AC

Input Type
Full Voltage

Transformer

Contact Block Mounting Position and Contact Arrangement Chart
4

3

1

2

Left

TOP

1
2
3
4

Center

L
NO 
NO
NC
NC

C

Right

R

Operator
Position



•	For more contact arrangement chart, see pages 26 to 28.

(14/05/22)

25

ø22 TW Series Selector Switch Contact Arrangement Charts
90° 2-position (Maintained / Spring Return)
Maintained
Positions
L

R

Operator
Contact
Code

L

01

—

11

(1NO-1NC)

—
103

20

—

02

—

(2NO)
(2NC)

—

109

22

(2NO-2NC)

110

111

117

31

(3NO-1NC)

40

(4NO)

107

—

118 
168 

2R 

119 
169 

120 

170 

4R 
121 

171 

26

R

L

L

R

Operator Positions

Circuit Mounting
Contact
No.
Position
—

(1NC)

Spring Return from Left

Knob, Lever, Key, Illuminated

10

(1NO)

Spring
Return
from Right

1
2
1
2
1
2
1
2
1
2
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
1
2
1
2
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

NO

R


L


R

Dummy

NC





Dummy

NO
NC
NC
NO
NO
NO
NC
NC
NO
NC
NO
NC
NO
NC
NC
NO
NC
NO
NC
NO
NO
NO
NC
NC
NC
NO
NO
NC
NC
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NC
NC
NO
NC
NO
NO
NC
NO
NC
NO
NC
NO
NC
NC
NO
NC
NO
NC
NO
NC
NO


















































Contact Block Mounting Position and
Contact Arrangement Chart





4
















TOP

2







3

1




















Left

Right












L
1
2
3
4

NO
NC
NO
NC

R


Operator
Position





•	On the contact arrangement marked with
 in the table, the rated current (load
switching current) is reduced to a half of
the rated current of the contact block.
The rated insulation voltage and the rated
thermal current remain unchanged.

Part No. Development
•	When circuit number is not required:

ASW 2 11
Contact Code (1NO-1NC)
2-position
•	When circuit number is required:

ASW 2 11 - 103
Circuit No.
Contact Code (1NO-1NC)
2-position

(14/05/22)

TW Series Selector Switch Contact Arrangement Charts ø22
45° 3-position (Maintained / Spring Return)
Maintained
Positions

L

Circuit Mounting
Contact
No.
Position

203
11
302
303
—
20
301
—
02
304

—

210

22

308

309

310

206
31
(3NO1NC)

207

212
13
313

—
40
305

—
04
314

(14/05/22)

L

R

L

R

Knob, Lever, Key, Illuminated

202

(2NO2NC)

R

L

C

C

C
R

Operator
Contact
Code

Spring Return Spring Return Spring Return
from Right
from Left
Two-way

C

1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

NO
NC
NC
NO
NO
NC
NC
NO
NO
NO
NO
NO
NC
NC
NC
NC
NO
NO
NC
NC
NC
NO
NC
NO
NO
NC
NO
NC
NO
NC
NC
NO
NC
NO
NC
NO
NO
NC
NO
NO
NC
NO
NO
NO
NO
NC
NC
NC
NC
NO
NC
NC
NO
NO
NO
NO
NO
NO
NO
NO
NC
NC
NC
NC
NC
NC
NC
NC

Operator Positions
L


C

R


































Contact Block Mounting Position and
Contact Arrangement Chart



4



TOP

2





3




1




Left






1
2
3
4

Center

L
NO 
NO
NC
NC

C

Right

R

Operator
Position







Part No. Development













•	When circuit number is not required:

ASW 3 22
Contact Code (2NO-2NC)
3-position
•	When circuit number is required:

ASW 3 22 - 210
Circuit No.


Contact Code (2NO-2NC)
3-position



27

ø22 TW Series Selector Switch Contact Arrangement Charts
45° 3-position (Maintained)

45° 4-position (Maintained)
Maintained

Maintained
L

2

Positions

C

Positions

R

1

3
4

Operator
Contact
Code
2S 

3S 

Circuit
No.
1361 

243 

233 

234 

4S 

235 

237 

240 

Mounting
Contact
Position
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

NO
NC
NO
NO
NC

Knob, Lever, Key,
Illuminated
Operator Positions
L


C

Operator
Contact
Code

Mounting
Contact
Position

R
3S 



1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

461 





405 

Dummy

NO
NC
NC
NO
NO
NC
NC
NC
NC
NO
NC
NO
NO
NO
NC
NO
NC
NC
NC
NO

Circuit
No.









407 
4S 



409 




411 



Knob, Lever
Operator Positions



1


NO
NC
NC



Dummy

NC
NC
NC
NC
NC
NC
NC
NO
NO
NC
NC
NC
NO
NC
NC
NO


















30° 5-position (Maintained)
Maintained




Positions

Contact
Code

Maintained

2

4S 

1336 

1337 

4S

1352 

1355 

1359 

28

Circuit
No.

1
2
3
4

Mounting
Contact
Position
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

NO
NO
NC
NC
NC
NO
NC
NC
NO
NC
NC
NO
NO
NC
NO
NC
NC
NC
NC
NC

501 

Knob, Lever, Key,
Illuminated
Operator Positions
L


C

4

R

2

1


NO
NC
NC
NO

3


5

1

2

3

4

5





TOP

Left






4

Knob, Lever
Operator Positions

Mounting
Contact
Position

R

L

3

1

C

Positions

Circuit
No.

4



45° 3-position (Maintained)

Contact
Code

3



Operator

Operator

2

1
2
3
4

Center

L
NO 
NO
NC 
NC

C

Right

R

Operator
Position













•	On the contact arrangement marked with  in the
table, the rated current (load switching current) is
reduced to a half of the rated current of the contact
block. The rated insulation voltage and the rated
thermal current remain unchanged.






(14/05/22)

TW Series Accessories and Replacement Parts ø22
Terminal Covers
Terminal Cover

HW-VL2

HW-VL3

HW-VL4

HW-VL5

HW-VL6

APS-PVL

Use of
termi­nal
covers
increases
the depth by
the dimen­
sions below.

Terminal
Cover

Switch/Pilot Light
•	Pilot light
APW
APQW

39.8H × 14.1W

39.8H × 8.7W

39.1H × 15.5W

Full Voltage

•	Pushbutton 1 contact block
ABW
AOW
CB
Terminal Cover
AVW
ABQW
ABFW
2 contact blocks
AJW
AOQW
CB
AOFW
CB
AXW
ABGW
AYW
3 contact blocks
CB CB
CB

40H × 14.8W

36H × 29.4W

X

Transformer
DC-DC Converter

•	Selector
switch
ASW

37.8H × 26W

X

+6mm
+3mm

X

X
2 pieces
+3.5mm
X
2 pieces

4 contact blocks
CB CB
CB CB

•	Illuminated
pushbutton
ALW
AOLW
ALFW
AOLFW
ALQW
AOLQW
AVLW
AYLW

Full Voltage, 1 or 3 contact
blocks
CB
FA

X
2 pieces

X
2 pieces

+3.5mm

Full Voltage, 2 or 4 contact
blocks

X
For con­
tact blocks
2 pieces

CB
CB

•	Illuminated Transformer
selector
DC-DC Converter
switch
ASLW
CB
CB Tr

X

X
For full
voltage
adapter

+3mm

+3mm

Ordering Terminal Covers
Terminal covers are ordered separately.
When ordering terminal covers, specify the Part No. and required quantity.

(14/05/22)

29

ø22 TW Series Accessories and Replacement Parts
Nameplates
Dimensions (mm)

Legend

Material

Part No.

NWA

20

29

NWA-0

Blank
Aluminium
0.8 mm thick

OFF

With Legend

NWA-∗

NWAQ
NWAQ-0

Blank
Aluminium
0.8 mm thick

OFF

With Legend

14.5

21

29

NWAQ-∗

Ordering No.

Package
Quantity

NWA-0

1

NWA-0PN10

10

NWA-∗

1

NWA-∗PN10

10

NWAQ-0

1

NWAQ-0PN10

10

NWAQ-∗

1

NWAQ-∗PN10

10

NWAS-0

1

Description
Black

White letters on
black background

Black

White letters on
black background

NWAS
45

45

Blank

Aluminium
0.8 mm thick

NWAS-0

Black
NWAS-0PN10

10

NWAL-0

1

NWAL
29

25

Blank

Aluminium
0.8 mm thick

NWAL-0

Black
NWAL-0PN10

10

NWAQL-0

1

NWAQL
29

25

Blank

Aluminium
0.8 mm thick

NWAQL-0

Black

14.5

NWAQL-0PN10

10

•	Specify a legend code in place of ∗ in the Ordering No.

Legends
Code
0
1
2
3
4
31
35
53

30

Legend
(blank)
ON
OFF
START
STOP
OFF-ON
HAND-AUTO
HAND-OFF-AUTO

(14/05/22)

TW Series Accessories and Replacement Parts ø22
Accessories
Material

Part No.

Ordering No.

Package
Quantity

Locking Ring Wrench

Dimensions

OR-14

OR-14

1

90

ø34

Rubber
(nitryl)

ø31

•	 Used to tighten the round bezel when installing
the TW switch/pilot light onto a panel.
ø46

Shape

16
For ø22mm units
(close mounting)

For ø22/ø25mm units

Lamp Holder Tool
OR-55

OR-55

1

ø14

Rubber
(nitryl)

ø11.6

•	 Used to install and remove LED/incandescent
lamps.

59

Contact Block Removal Tool

TW-KC1

TW-KC1

1

130

Nut Locking Wrench

39

ø19

Metal
(zinc-plated)
Rubber
(nitryl)

23

•	 Used to remove contact blocks, transformers,
lenses and adapters. Can also be used to
determine panel thickness adjustment.

•	 Used to tighten the locking nuts inside of the
square bezel.This tool can be inserted into the
OR-14 locking ring wrench.
20

TW-KQ2

1

25.7

TW-KQ2

22.5

Metal
(nickel-plated)

80

Anti-rotation Ring

•	 Used to prevent the operator from rotating.
Generally used when using no nameplates on
selector switches.

OGL-31

OGL-31PN10

10
10.2

Metal
(zinc-plated)

ø22

Rubber Mounting Hole Plug

ø27.4

0.8

•	 Used to plug unused ø22.2mm mounting
holes.
ø29

5

Diecast Metal
(locking ring:
polyamide)

LW9Z-BM

LW9Z-BM

1

•	 Used to plug unused ø22.2mm mounting holes.
•	 Tightening torque: 1.2 N·m
•	 Degree of protection: IP66 (without the 3.2mm
recess in the mounting hole)
ø25.8

12

Gasket
Locking Ring

Plastic
(polyamide)

LW9Z-BP1

LW9Z-BP1

1

Barrier

Polyamide

HW-VL1

HW-VL1PN10

10

•	 Used to plug the unused ø22.2mm mounting
holes.
•	 Tighten the locking ring to a torque of 2.0 N·m.
IP65
•	 Mounting panel thickness: 0.8 to 6 mm
•	 Used to prevent contact
between adjacent
lead wires when units
are mounted closely.
Barriers should be
always used in close
mounting.

45

Plastic Mounting Hole Plug

20

(14/05/22)

3

Metallic Mounting Hole Plug

ø25

3.5

OB-31PN05

3.5

Rubber (black)
OB-31
(nitryl)

1.5

31

ø22 TW Series Accessories and Replacement Parts
Accessories

OCW-99

Ordering No.

OCW-99

Package
Quantity

1

Description
•	 Oiltight rubber boot used for pushbuttons and
selector switches.
•	 Temperature range: –5 to +60°C
•	 Black
OCW-99

2.2

For 1 layer of
contact blocks
(2 contact
blocks)

Part No.

Rubber
(nitryl)

1

OCW-299

OC-31

OC-31

1

OC-32

OC-32

1

Rubber
(EPDM)

For extended
pushbuttons
(ABW2/AOW2)
Button Cover
For flush
pushbuttons
(ABW1/AOW1)

OCW-10

OCW-10

1

65.5

14

38

•	 Used to cover and pro­tect
pushbuttons where units
are sub­ject to water
splash. Not suitable for
out­door use or where the
units are subject to oil
splash.

ø32.6
18 (OC-31)
22 (OC-32)

•	 Metallic bezels covered with rubber boot to
enhance waterproof and oiltight characteristics.
•	 Button is installed in the cover. Remove the
button from the pushbutton before using the
button cover.

•	 : B (black), G (green), R (red), Y (yellow)

ø32

For extended
pushbuttons
(ABW2/AOW2)

OCW-11

OCW-11

M22 P1.0

1

18.5

Button
installed

Button
installed

21
Extended

Flush

Padlock Cover

9

ø31

9

M22 P1.0

ø26

Rubber
(nitryl)

•	 Used to protect momentary and maintained
pushbuttons, illuminated pushbuttons, knobs
selector switches, and key selector switches.
82.5

1

70

30

HW9Z-KL1 HW9Z-KL1

6.5
R6

Polyarylate
(gasket: nitryl
rubber)

Panel Thickness
0.8 to 3.2

93

For flush
pushbuttons
(ABW1/AOW1)

OCW-299

ø31

Button
Clear Boot

OCW-299

50

For 2 layers of
contact blocks
(4 contact
blocks)

45.5

14

38

ø32

Contact Rubber
Boot

Material

48

Shape

24 (inside)

2

2.

Padlock Cover
for Key Selector Switches

ø2

)

0 4
ø5 44.
:ø
(ID

Key hole ø8

29.5
30

Waterproof Rubber
Gasket 0.5t

•	For ASWK key selector switches.

Metal
(copper)

HS9Z-PC22 HS9Z-PC22

1

Note:	 Specify a button color code or lens color code in place of  or  in the Ordering No.

32

(14/05/22)

TW Series Accessories and Replacement Parts ø22
Accessories
Shape

Material

ø40mm Lens

Part No.

Ordering No.

Package
Quantity

ALW4L-

ALW4L-

1

ALW4LD-

ALW4LD-

1

ALW4BL-

ALW4BL-

1

Non-marking
Plastic
Marking

Plastic Bezel

➊

➋

➌

➍

➎

Selector Operator

➋

➊

➌

➍

	

W (white)

:	G (green), R (red),
S (blue), W (white)

	

AW-RP1BPN05

5

AW-FP1B

AW-FP1B

1

AW-FP2B

AW-FP2B

1

AW-H1B

AW-H1B

1

AW-Q1B

AW-Q1B

1

AW-QF1B

AW-QF1B

1

AW-R1

AW-R1PN05

5

Aluminium color (standard)

AW-R1B

AW-R1B

1

Black

AW-F1

AW-F1

1

(for illuminated
pushbuttons)

AW-F2

AW-F2

1

➍Mushroom

AW-G4

AW-G4

1

➊Flush
Aluminium

:	A (amber)

Black

Aluminium color (standard)

➊Knob

ASWHHY-➁

ASWHHY-➁PN02

2

➋Lever

ASWHHL-➁

ASWHHL-➁PN02

2

Specify a color code in place of ➁.
B (black), G (green), R (red)

➌Round

ASWHHM-B

ASWHHM-BPN02

2

Black only

TW-HC1➁

TW-HC1➁PN05

5

Specify a color code in place of ➁.
B (black), G (green), R (red), S (blue),
W (white), Y (yellow)

ASLWDDY-➁

ASLWDDY-➁

1

Specify a color code in place of ➁.
A (amber), W (white), Y (yellow)

ASLWLDY-➁

ASLWLDY-➁

1

Specify a color code in place of ➁.
G (green), R (red), S (blue)

➍Color Insert
➎

:	A (amber),

AW-RP1B

➋Extended
➌Extended

➍

S (blue)

➋Extended
➌Extended

Aluminium Bezel

➌

	

➊Flush

➎Square
➏Extended

➋

•	 Applicable
unit:
ALW3B,
AOLW3B
•	 Marking plate
is included

:	G (green), R (red),

1

with Full
Shroud

➊

•	 Applicable
unit:
ALW3,
AOLW3

ALW4BLD- ALW4BLD-

(for illuminated
pushbuttons)
➍Square round Plastic
(for round
pushbuttons)

➎

Remarks

Plastic

➎Illuminated
selector

Metal Protector

•	 Used to protect flush pushbuttons from
inadvertent operation.

Metal

OLW-C

OLW-C

1

Mounting Centers
50 min.

18.6

ø22.5

(14/05/22)

R4

2.5

15

1.6t

33

ø22 TW Series Accessories and Replacement Parts
Maintenance Parts
Shape
Lens (for pilot lights)

Material
AS

Round flush
AS,
Marking
Round extended

AS

Square flush

AS,
Marking

Lens (for illuminated
pushbuttons)

AS
Round extended
AS,
Marking
Square extended

Lens (for pushlock
turn reset)

AS

AS
ø29mm mushroom
AS,
Marking

APW1L-PN05

5

G (green), R (red), S (blue)

APW1LD-

APW1LD-PN05

5

A (amber), W (white), Y (yellow)

APW11L-

APW11L-PN05

5

C (clear), G (green), R (red),
S (blue)

APW11LD-

APW11LD-PN05

5

A (amber), Y (yellow)

APW2L-

APW2L-PN05

5

G (green), R (red), S (blue)

APW2LD-

APW2LD-PN05

5

A (amber), W (white), Y (yellow)

APQW11L-

APQW11L-PN05

5

C (clear), G (green), R (red),
S (blue)

5

A (amber), Y (yellow)

APQW11LD- APQW11LD-PN05
ALW2L-

ALW2L-PN05

5

G (green), R (red), S (blue)

ALW2LD-

ALW2LD-PN05

5

A (amber), W (white), Y (yellow)

ALW21L-

ALW21L-PN05

5

C (clear), G (green), R (red),
S (blue)

ALW21LD-

ALW21LD-PN05

5

A (amber), Y (yellow)

ALQW21L-

ALQW21L-PN05

5

C (clear), G (green), R (red),
S (blue)

ALQW21LD- ALQW21LD-PN05

5

A (amber), Y (yellow)

ALW3L-

ALW3L-PN02

2

G (green), R (red), S (blue)

ALW3LD-

ALW3LD-PN02

2

A (amber), W (white), Y (yellow)

ALW31L-

ALW31L-PN02

2

C (clear), G (green), R (red),
S (blue)
A (amber), Y (yellow)

ALW31LD-PN02

2

AVLW3L-RPN02

2

AS,
Marking
AS

AVLW31L-R

AVLW31L-RPN02

2

AVLW4L-R

AVLW4L-RPN02

2

Round flush

ABW1B-

ABW1B-PN05

5

Round extended

ABW2B-

ABW2B-PN05

5

Square flush

ABQW1B-

ABQW1B-PN05

5

Square extended

ABQW2B-

ABQW2B-PN05

5

B (black)
G (green)
R (red)
S (blue)
W (white)
Y (yellow)

ABW3B-

ABW3B-PN02

2

ABW4B-

ABW4B-PN02

2

AVW3B-

AVW3B-PN02

2

R (red), Y (yellow)

AVW4B-

AVW4B-PN02

2

R (red), Y (yellow)

ø40mm push pull

AYW4B-

AYW4B-PN02

2

B (black), G (green), R (red),
S (blue), W (white), Y (yellow)

Round flush

APW2B

APW2BPN05

5

Square flush

APQW1B

APQW1BPN05

5

ALW2B

ALW2BPN05

5

Square extended

ALQW2B

ALQW2BPN05

5

ø29/40mm mushroom

ALW3B

ALW3BPN05

5

APW00LN

APW00LNPN05

5

APW00L

APW00LPN05

5

ø29mm mushroom

Waterproof Lens

Color Code

APW1L-

ALW31LD-

ø40mm mushroom
ø29mm pushlock turn
reset
ø40mm pushlock turn
reset

Marking Plate
(for illuminated
pushbuttons)

Package
Quantity

AVLW3L-R

ø40mm mushroom

Marking Plate
(for pilot lights)

Ordering No.

AS
ø29mm mushroom

Button

Part No.

Round extended

Polyacetal

Acrylic

For APQW

•	 White

Acrylic
For ALQW

Note:	 Specify a button color code or lens color code in place of  or  in the Ordering No.
Use a clear lens for white or pure white illumination.

34

(14/05/22)

TW Series Accessories and Replacement Parts ø22
Maintenance Parts
Shape

Specification

Contact Block

Part No.

Ordering No.

Package
Quantity

Housing

Remarks
Push Rod

1NO contact

HW-C10

HW-C10

1

Blue

Green

1NC contact

HW-C01

HW-C01

1

Purple red

Red

HW-C10R HW-C10R

1

Blue

Black

HW-C01R HW-C01R

1

Purple red

White

TW-DB

10

•	 Used for non-illuminated units with
1NO or 1NC contact blocks.
•	 Black

2

•	 Adapter with M3.5 screws used for
illuminated pushbutton or illuminated
selector switch. Snaps on to the back
of the contact block.
•	 Used with 2 or 4 contact blocks.
•	 Black

HWHW-DA1B
DA1BPN02

2

•	 Adapter with M3.5 screws used for illuminated pushbuttons or illumi­nated
selector switch.
•	 Used with 1 or 3 contact blocks.
•	 Black

Metal

TW-SK-0

TW-SK-0PN02

2

•	 For Key Selector Switch
•	 For Pushlock Key Reset

Current Draw
AC
DC

Part No.

Ordering No.

EM contact
(early make)
LB contact
(late break)
Dummy Block

TW-DBPN10

Full Voltage Adapter
(for 2 or 4 contact blocks)
TW-DA1B TW-DA1BPN02

Full Voltage Adapter
(for 1 or 3 contact blocks)

Spare Key

LED Lamps (LSTD)
Dimensions

Operating
Voltage

6V AC/DC ±5% 8 mA

2.4

12V AC/DC
±10%

(20.8)
18.4

Voltage
Base (x2) BA9S/13
Grommet (x1)

24V AC/DC
±10%­

7 mA
(A, R, W)
LSTD-6
5.5 mA
(G, PW, S)

LSTD-6
LSTD-6PN10
LSTD-1

11 mA

10 mA

LSTD-1
LSTD-1PN10
LSTD-2

11 mA

10 mA

LSTD-2
LSTD-2PN10

Illumination
Color Code
Specify a color
code in place of 
in the Ordering No.
A:	amber
G:	green
PW:	pure white
R:	red
S:	blue
W:	white
Use a pure white
(PW) LED lamp
with yellow (Y) lens.

Package
Quantity

Base

1
10
1
BA9S/13
10
1
10

Incandescent Lamps (LS)
Dimensions

Rated
Operating
Voltage

Lamp Ratings

Part No.

6V AC/DC

1W (6.3V)

LS-6

12V AC/DC

1W (18V)

LS-8
1

(14/05/22)

ø11±1

Base BA9S/13

22.5 ±1.5

Package
Quantity

18V AC/DC

1W (24V)

LS-2

24V AC/DC

1W (30V)

LS-3

35

ø22 TW Series Accessories and Replacement Parts
Transformer Unit
Shape
Transformer Unit

Primary Voltage

Secondary Volt­age

Part No.
TW-T16B

100/110V AC
120V AC

TW-T126B

5.5V

200/220V AC

TW-T26B
TW-T246B

240V AC

Transformer
Shape

Secondary
Voltage

Primary Voltage

Din Rail Mount Transformer
For 6V

Part No.

100/110V AC

TWR516

115/120V AC

TWR5126

200/220V AC

TWR526

230/240V AC

Applicable Load

LSTD-6 LED lamp (6V AC/DC) or
LS-6 incandescent lamp (6V AC/DC, 1W)

TWR5246

5.5V AC, 1W

380V AC

TWR5386

400/440V AC

TWR546

480V AC

TWR5486

Specifications

Dimensions

3

Shock Resistance
Dielectric Strength
Terminal Screw
Applicable Wire
Weight (approx.)

22
30

2

Primary Side

40
48

2–ø3.3
Mounting Hole

52

Terminal Cover

40
41
45.5

100 MΩ minimum (500V DC megger)
–30 to +60°C (no freezing)
–40 to +80°C (no freezing)
35 to 85% RH (no condensation)
Damage Limits: 30 Hz, amplitude 1.5 mm
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Damage limits, Operating Extremes: 1,000 m/s2
2,500V AC, 1 minute
M3.5
2 mm2 maximum, 2 wires maximum
87g

Vibration Resistance

JAPAN

Secondary Side

600V

PRI.

Current Draw
Rated Insulation
Voltage
Insulation Resistance
Operating Temperature
Storage Temperature
Operating Humidity

M3.5 Terminal Screw

1

Operating Voltage

SEC. 4

100/110V AC, 115/120V AC, 200/220V AC,
230/240V AC, 380V AC, 400/440V AC, 480V AC
(50/60Hz)
2.4 VA

BAA1000

Accessories
DIN Rail
Part No.
BAA1000
BAP1000

Ordering No.
BAA1000PN10
BAP1000PN10

Length
1000 mm
1000 mm

Weight (approx.)
200g
320g

Material
Aluminum
Steel

Package Quantity
10
10

End Clip

BNL6

Ordering No.

BNL6PN10

Applicable DIN Rail

BAA1000
BAP1000

Weight (approx.)

15g

Material

Package Quantity

Steel
(Zinc-plated)

Dimensions
(24)

Part No.

10
45

9

•	Use plastic end clip BC9Z-E/NS35N when using 400/440V AC primary voltage transformers.

36

(14/05/22)

TW Series Instructions ø22
Safety Precautions
•	Turn off the power to the TW series switches & pilot lights
before starting installation, removal, wiring, maintenance,
and inspection of the products. Failure to turn power off
may cause electrical shocks or fire hazard.
•	To avoid a burn on your hand, use the lamp holder tool
when replacing lamps.
•	For wiring, use wires of a proper size to meet the voltage and current requirements. Tighten the M3.5 terminal
screws to a tightening torque of 1.0 to 1.3 N·m. Failure to
tighten terminal screws may cause overheat and fire.

•	Use HW-C contact blocks for the TW series. Do not replace with or add conventional TW series contact blocks.
Using a different type of contact block may lead to
malfunc­tion.
TW
Contact Block

HW-C
Contact Block

Rectangular
Holes

Instructions
Panel Mounting
Panel thickness adjustment ring is used for the TW series. To attach the TW series to the panel, follow the procedures below.

Panel Thickness Adjustment

Attaching the Unit to the Panel
with the Bezel

Attaching the Button, Lens, and
Knob

Bezel

Mounting order

Panel thickness adjustment ring

Panel

Lens

Panel

Installation method
Type

Attach the unit with the panel
thickness scale facing up.

Remarks

Method

Flush/Extended pushbuttons,
Square lens, Selector operator

Press in

29mm/40mm mushroom
button/lens, Dome lens

Screw in

For tightening or removing round
bezels.

Locking ring wrench

For tightening or removing square
bezels.

Tools Nut locking wrench
Contact block removal
Panel thickness adjustment
tool

Adjusting Panel Thickness
The panel thickness ring provides adjustment from 1 to 6
mm in 1-mm increments. Set the panel thickness to line A.
Rotate the ring until the desired thickness indication around
the periphery is aligned with line A, as shown below.

For installing or removing water­
proof lenses after the bezel is
attached.

For installing or removing round
lenses.

Using the Contact Block Removal Tool to Adjust Panel
Thickness
Panel thickness can easily be adjusted to the values shown
below by inserting the contact block removal tool between
the adjustment ring and base.

Scale on Adjustment (in 0.1 mm)
0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0

1.6 mm
0.1 mm

2.3 mm
1

2

3

4

5

1 mm

Contact Block
Removal Tool

Panel Thickness
Adjustment Ring

Panel Thickness Scale
(in 1 mm on the operator)

3.5 mm

6

A
3
5

2
4
6

Ex. Panel thickness 2 mm

3
5

4
6

Ex. Panel thickness 2.6 mm

1 mm

2 mm
3.2 mm

Note:	 When a nameplate or an anti-rotation ring is used, add
0.8mm to the panel thickness.
Total thickness
= Panel thickness + 0.8mm (nameplate or anti-rotation ring thickness)

(14/05/22)

37

ø22 TW Series Instructions
Mounting into Panel Cut-out with Bezel
Insertion into Panel Cut-out
Insert the base into the panel
cut-out making sure that the
panel thickness scale is facing
up.

Square Bezel
1.	 Insert the base plate from
the front.

Base Plate

Panel thickness
adjustment ring

2.	Insert the lock nut. For
easy installation, use the
nut locking wrench.

Round Bezel
All round bezels are screw-in
type. Be sure to use the locking
ring wrench to tighten the bezel.
Locking Ring Wrench
OR-14 (optional)

Remove

Tighten
Side A

	 Nut Locking Wrench
	 TW-KQ2 (optional)

3.	Mount the square bezel.
The bezel will snap onto the
base plate.

Use side B when
mounting the units
closely.

Side B

Lock Nut

Square Bezel

•	Recommended tightening torque is 2.0 N·m.
Use side B when mounting
units closely.

5

Marking Plate

[Square Illuminated Pushbutton]

Marking Plate

Flat screwdriver
(5mm wide at
maximum)

2.	Removing the Marking Plate
•	Pilot Light
Insert the screwdriver into the
recess of the lens.

Square (Illuminated
Pushbutton)
19

21

21

9

0.
3

1.0

ø1

4.4

ø1

Square (Pilot Light)

2.6

Insert

Square Lens

1.	 Removing the Square Lens
Insert the screwdriver into the
recess of the lens and lightly
push out the lens.

Mushroom
1.

4

[Square Pilot Lens]

Square Lens
Press in

Round

1.2

Lens Structure and Marking Plate
All square lens units are marking types. To engrave on the
marking plate, remove the marking plate from the lens.

Marking Plate Engraving Area

22

Installing Buttons, Lenses, and Operators

Note:	 The depth of the engraving must be within 0.5 mm.

Installing Round Lens and Waterproof Lens
When installing or removing round lens of pilot lights and
illu­minated pushbuttons and waterproof lens of square pilot
lights and illuminated pushbuttons, press the rubber part of
the contact block removal tool onto the lens or waterproof
lens for secure tightening and easy removal.

Small flat screwdriver

Lens Retainer
Waterproof Lens

•	Illuminated Pushbuttons
Insert the screwdriver into the
hook and lightly push out the
lens.
Flat screwdriver
(5mm wide at
maximum)

[Round Marking]
Lens

Marking
Plate
Press in

38

3.	Other Notes
The square lens of the illumi­
nated pushbutton cannot be
used without waterproof lens.
Always use the waterproof
lens.
Be sure to use the marking
plate even when it is not
engraved.

(14/05/22)

TW Series Instructions ø22
Installation of Selector Operators
1.	 The shaft of each selector or illuminated selector switch
has a recess to identify in which direction to install the
operator. Align the operator with the recess and press in
the operator.
2.	Press color insert (non-illuminated) into the opera­tor. The
color insert retains the operator

Removing the Operator
Recess

Flat
screwdriver

Color insert

Recess

1.	Removing the Color
Insert
Insert a flat screwdriver
into the recess of the color
insert. Turn the screwdriver
to push out the insert from
the operator

Press in

2.	Removing the Operator
(Non-illuminated)
Push the operator sideways
as shown in the left photo to
remove the operator.

Press in

Illuminated
Selector Switch

Selector Switch
(non-illuminated)

2-Position, 90° 3-Position, 45° 4-Position, 45° 5-Position, 30°
L

L C R

R

1 2 3

1

2 3 4

5

4

Recess

3.	Removing the Operator
(Illuminated)
Insert a flat screwdriver into
the recess of the operator
and turn the screwdriver to
remove the operator.

Flat
screwdriver

[Example]
C
L

L

R

L
C
R

C
R

Standard Position

The non-illuminated operators can be installed in positions
other than the standard position as shown above.

Removing Contact Blocks, Transformers
and Full Voltage Adapters
Insert the end of the contact block removal tool into the
snap-fit latch of the contact block (or transformer, fullvoltage adapter) and pull the tool as shown below.
Pull

Collective Mounting
When mounting the units closely in a horizontal row on
30-mm centers, use optional barriers to prevent
interconnection between adjoining terminals. The barriers
can be attached simply by pressing them onto the sides of
contact blocks.
30

30

Barrier (HW-VL1)

Tightening Torque for Terminal Screws
Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3
N·m.

(14/05/22)

39

ø22 TW Series Instructions
Installation of LED Illuminated Units
1.	 Note the polarity for wiring when connecting to DC-DC
converter unit.

2.	Transformer type units are recommended for use in areas
subjected to noise.

3.	Notes for Pure White LED Lamps
•	Do not use the pure white LED outdoors, otherwise it will
lead to the degradation of brightness and color. Do not
remove or apply shock to the cap on the pure white LED
lamp, otherwise it may break or damage the cap.
•	For the pure white LED, use a white lens. The illumination
color will be dull if a different color is used.

Notes on LED Illuminated Units

[Protection Example 1] For AC circuit

Terminal No.
X1
X2

Polarity
Positive
Negative

LED lamps consist of semiconductors. If the applied voltage
exceeds the rated voltage, LED elements may deteriorate
due to overheat, resulting in significant decrease in lumi­
nance, hue change, or failure of lighting. Also, if an extrane­
ous noise, transient voltage, or transient current is applied
to the circuit, similar effects may occur. When using LED
lamps, observe the following instructions.
Rated Voltage
The LED lamps are rated at 6V, 12V, or 24V AC/DC, and
can be used within ±10% the rated voltage of either AC or
DC.
DC Power
1.	 Switching power supply
Regulated voltage from switching power supply is best
suited. Make sure to use within the rated voltage of the
LED lamp.
2.	Rechargeable battery
Note that the battery voltage may exceed the rated volt­
age of the LED lamp while the battery is being charged
and immediately after the charging is complete. Be sure to
use the LED lamp on a voltage of ±10% the rated volt­age.
3.	Full-wave rectification
Since the LED lamp is AC/DC compatible, a diode bridge
for rectification is not necessary. If the LED lamp is used
on a full-wave rectification current through a diode bridge,
the rectifier diodes will reduce the voltage, resulting in
lower luminance.
4.	Single-phase half-wave rectification
This is not suitable for the power source of LED lamps.
Use constant-voltage DC power.

LED with
transformer
C
LED with
LED
transformer

C
Relay Ry
coil or
solenoid

R

LED

R

(Reference values) R: 120Ω
C: 0.1 μF

[Protection Example 2] For DC circuit
+

(Reference values of the diode)
Forward current: More than the Ry coil current
Reverse withstand voltage: Ry coil current ¥ 10
Relay Ry
coil or
solenoid

LED

Diode

–

Countermeasures against Dim Lighting
1.	 Leakage currents through the transistors or a contact
protection circuit may cause the LED lamp to illuminate
dimly even when the output is off.
2.	When the LED lamp is illuminated by a transistor output,
take the following measure.
[Circuit Example]
Connect shunt resistor R in parallel with the LED lamp.

R

Noise
LED elements deteriorate due to extraneous noise, resulting
in significant decrease in luminance, hue change, or failure
of lighting. When such effects are anticipated, take a protec­
tion measure shown below, such as RC elements or a surge
absorber.

LED

Io

Io: Leakage current when the output is off
R: Shunt resistor

Specifications and other descriptions in this brochure are subject to change without notice.
6-64, Nishi-Miyahara 2-Chome, Yodogawa-ku, Osaka 532-0004, Japan
Tel: +81-6-6398-2527, Fax: +81-6-6398-2547
E-mail: marketing@idec.co.jp

IDEC CORPORATION (USA)

Wendenstrasse 331, 20537 Hamburg, Germany
Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24
E-mail: service@idec.de

IDEC CANADA LIMITED

Room 701-702 Chong Hing Finance Center,
No. 288 Nanjing Road West, Shanghai 200003, PRC
Tel: +86-21-6135-1515
Fax: +86-21-6135-6225 / +86-21-6135-6226
E-mail: idec@cn.idec.com

3155 Pepper Mill Court, Unit 4
Mississauga, Ontario, L5L 4X7, Canada
Tel: +1-905-890-8561, Toll Free: (800) 262-IDEC (4332)
Fax: +1-905-890-8562
E-mail: sales@ca.idec.com

IDEC AUSTRALIA PTY. LTD.

www.idec.com

IDEC ELEKTROTECHNIK GmbH

1175 Elko Drive, Sunnyvale, CA 94089-2209, USA
Tel: +1-408-747-0550 / (800) 262-IDEC (4332)
Fax: +1-408-744-9055 / (800) 635-6246
E-mail: opencontact@idec.com

IDEC (SHANGHAI) CORPORATION

IDEC (BEIJING) CORPORATION

IDEC IZUMI (H.K.) CO., LTD.

Unit G & H, 26/F., MG Tower,
No. 133 Hoi Bun Road, Kwun Tong, Kowloon,
Hong Kong
Tel: +852-2803-8989, Fax: +852-2565-0171
E-mail: info@hk.idec.com

IDEC TAIWAN CORPORATION

8F-1, No. 79, Hsin Tai Wu Road, Sec. 1,
Hsi-Chih District, 22101 New Taipei City, Taiwan
Tel: +886-2-2698-3929, Fax: +886-2-2698-3931
E-mail: service@tw.idec.com

IDEC IZUMI ASIA PTE. LTD.

Unit 17, 104 Ferntree Gully Road,
Oakleigh, Victoria 3166, Australia
Tel: +61-3-8523-5900, Toll Free: 1800-68-4332
Fax: +61-3-8523-5999
E-mail: sales@au.idec.com

Room 211B, Tower B, The Grand Pacific Building,
8A Guanghua Road, Chaoyang District,
Beijing 100026, PRC
Tel: +86-10-6581-6131, Fax: +86-10-6581-5119

No. 31, Tannery Lane #05-01,
HB Centre 2, Singapore 347788
Tel: +65-6746-1155, Fax: +65-6844-5995
E-mail: info@sg.idec.com

IDEC ELECTRONICS LIMITED

Unit AB-3B2, Tian Xiang Building, Tian’an Cyber Park,
Fu Tian District, Shenzhen, Guang Dong 518040, PRC
Tel: +86-755-8356-2977, Fax: +86-755-8356-2944

20th Fl., Sorachai Bldg., No.23/78,
Soi Sukhumvit 63, Sukhumvit Rd.,
Klongton-nua, Wattana, Bangkok 10110
Tel: +662-392-9765, Fax: +662-392-9768
E-mail: sales@th.idec.com

Unit 2, Beechwood, Chineham Business Park,
Basingstoke, Hampshire RG24 8WA, UK
Tel: +44-1256-321000, Fax: +44-1256-327755
E-mail: sales@uk.idec.com

IDEC (SHENZHEN) CORPORATION IDEC ASIA (THAILAND) CO.,LTD.

Cat. No. EP1432-3 MAY 2014 PDF (14/05/22)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2014:05:22 10:50:30+09:00
Creator                         : Adobe InDesign CS5.5_J (7.5.3)
Modify Date                     : 2014:05:22 10:56:09+09:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Instance ID                     : uuid:fc6de1fa-89f7-47ef-b09e-8aad321b7287
Document ID                     : xmp.did:EA3A823B53E1E31192BF96EA70C7E42D
Original Document ID            : adobe:docid:indd:064dd86a-3e8a-11e1-aa81-bbbf6c721254
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:A851FD7F50E1E31192BF96EA70C7E42D
Derived From Document ID        : xmp.did:A21D092E93C6E311B00CB61FF2BF2FE7
Derived From Original Document ID: adobe:docid:indd:064dd86a-3e8a-11e1-aa81-bbbf6c721254
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:417C3F5F4094E311B9B19CB2003332C1, xmp.iid:427C3F5F4094E311B9B19CB2003332C1, xmp.iid:A840B84C5794E311B9B19CB2003332C1, xmp.iid:A940B84C5794E311B9B19CB2003332C1, xmp.iid:94F57B3E6D94E311B9B19CB2003332C1, xmp.iid:905CA85C3395E311BCA7F375E821CDE0, xmp.iid:F8361ECC3395E311BCA7F375E821CDE0, xmp.iid:62F019E43495E311BCA7F375E821CDE0, xmp.iid:8CBA4FD65295E311BCA7F375E821CDE0, xmp.iid:FA2E4CD6009DE311BF38EB152C3314E8, xmp.iid:F401599D199DE311BF38EB152C3314E8, xmp.iid:D6074E841A9DE311BF38EB152C3314E8, xmp.iid:D14103FE1A9DE311BF38EB152C3314E8, xmp.iid:D24103FE1A9DE311BF38EB152C3314E8, xmp.iid:CBBFA4591C9DE311BF38EB152C3314E8, xmp.iid:008E59F3209DE311BF38EB152C3314E8, xmp.iid:018E59F3209DE311BF38EB152C3314E8, xmp.iid:23BB100A249DE311BF38EB152C3314E8, xmp.iid:507203BF279DE311BF38EB152C3314E8, xmp.iid:517203BF279DE311BF38EB152C3314E8, xmp.iid:326876232B9DE311BF38EB152C3314E8, xmp.iid:A1511BD7AD9DE3119E9AA44F8EEF392B, xmp.iid:A2511BD7AD9DE3119E9AA44F8EEF392B, xmp.iid:C9CB7094C39DE3119E9AA44F8EEF392B, xmp.iid:3E1C85A0C39DE3119E9AA44F8EEF392B, xmp.iid:3F1C85A0C39DE3119E9AA44F8EEF392B, xmp.iid:3E70739AC49DE3119E9AA44F8EEF392B, xmp.iid:3F70739AC49DE3119E9AA44F8EEF392B, xmp.iid:55E371D5C49DE3119E9AA44F8EEF392B, xmp.iid:82FF7A1EC59DE3119E9AA44F8EEF392B, xmp.iid:F69DD808F59DE3119E9AA44F8EEF392B, xmp.iid:F79DD808F59DE3119E9AA44F8EEF392B, xmp.iid:AD8895817F9EE3118EDDC73679502E92, xmp.iid:632996857F9EE3118EDDC73679502E92, xmp.iid:642996857F9EE3118EDDC73679502E92, xmp.iid:1FDDE9D67F9EE3118EDDC73679502E92, xmp.iid:2DF506D2819EE3118EDDC73679502E92, xmp.iid:2EF506D2819EE3118EDDC73679502E92, xmp.iid:BE05F3BD829EE3118EDDC73679502E92, xmp.iid:BF05F3BD829EE3118EDDC73679502E92, xmp.iid:08B7E416849EE3118EDDC73679502E92, xmp.iid:E1C538CC8C9EE3118EDDC73679502E92, xmp.iid:E2C538CC8C9EE3118EDDC73679502E92, xmp.iid:92770A1C8D9EE3118EDDC73679502E92, xmp.iid:437020238D9EE3118EDDC73679502E92, xmp.iid:978A912B8D9EE3118EDDC73679502E92, xmp.iid:1BD8F1978D9EE3118EDDC73679502E92, xmp.iid:815FF8708E9EE3118EDDC73679502E92, xmp.iid:81B184EEA19EE3118EDDC73679502E92, xmp.iid:4D93C829A79EE3118EDDC73679502E92, xmp.iid:611114EFAE9EE3118EDDC73679502E92, xmp.iid:621114EFAE9EE3118EDDC73679502E92, xmp.iid:348665A5B29EE3118A5C91676B68FBA4, xmp.iid:358665A5B29EE3118A5C91676B68FBA4, xmp.iid:5217E3FBB29EE3118A5C91676B68FBA4, xmp.iid:E9AFA646B49EE3118A5C91676B68FBA4, xmp.iid:59D3E189B59EE3118A5C91676B68FBA4, xmp.iid:5341509FB59EE3118A5C91676B68FBA4, xmp.iid:5441509FB59EE3118A5C91676B68FBA4, xmp.iid:DFB47816B69EE3118A5C91676B68FBA4, xmp.iid:DE226144B89EE3118A5C91676B68FBA4, xmp.iid:19527A4FB89EE3118A5C91676B68FBA4, xmp.iid:020735D5B89EE3118A5C91676B68FBA4, xmp.iid:906BA8FBB89EE3118A5C91676B68FBA4, xmp.iid:D77E746EB99EE3118A5C91676B68FBA4, xmp.iid:C167E06EBB9EE3118A5C91676B68FBA4, xmp.iid:564C0AF9BC9EE3118A5C91676B68FBA4, xmp.iid:71D75500BD9EE3118A5C91676B68FBA4, xmp.iid:F89A9509BD9EE3118A5C91676B68FBA4, xmp.iid:5865EB15BD9EE3118A5C91676B68FBA4, xmp.iid:5965EB15BD9EE3118A5C91676B68FBA4, xmp.iid:902909B6BD9EE3118A5C91676B68FBA4, xmp.iid:98EC1A4BBF9EE3118A5C91676B68FBA4, xmp.iid:B9E182D4409FE311AF538D8A17AEEE90, xmp.iid:ADEC8556419FE311AF538D8A17AEEE90, xmp.iid:D9C777E560AEE311A997AB32F85B8500, xmp.iid:E507F7E163AEE311A997AB32F85B8500, xmp.iid:753356D064AEE311A997AB32F85B8500, xmp.iid:BA6E662B93C6E311B00CB61FF2BF2FE7, xmp.iid:A21D092E93C6E311B00CB61FF2BF2FE7, xmp.iid:F32D317E94C6E311B00CB61FF2BF2FE7, xmp.iid:F42D317E94C6E311B00CB61FF2BF2FE7, xmp.iid:6BC8F46CBEC6E311B00CB61FF2BF2FE7, xmp.iid:A851FD7F50E1E31192BF96EA70C7E42D, xmp.iid:EA3A823B53E1E31192BF96EA70C7E42D
History When                    : 2014:02:13 08:49:54+09:00, 2014:02:13 08:49:54+09:00, 2014:02:13 11:34:02+09:00, 2014:02:13 11:34:02+09:00, 2014:02:13 14:11:07+09:00, 2014:02:14 13:49:18+09:00, 2014:02:14 13:52:25+09:00, 2014:02:14 14:00:15+09:00, 2014:02:14 17:34:36+09:00, 2014:02:24 12:07:47+09:00, 2014:02:24 15:05:09+09:00, 2014:02:24 15:11:36+09:00, 2014:02:24 15:15+09:00, 2014:02:24 15:15+09:00, 2014:02:24 15:24:44+09:00, 2014:02:24 15:57:39+09:00, 2014:02:24 15:57:39+09:00, 2014:02:24 16:19:46+09:00, 2014:02:24 16:46:18+09:00, 2014:02:24 16:46:18+09:00, 2014:02:24 17:10:35+09:00, 2014:02:25 08:46:11+09:00, 2014:02:25 08:46:11+09:00, 2014:02:25 11:21:48+09:00, 2014:02:25 11:22:08+09:00, 2014:02:25 11:22:09+09:00, 2014:02:25 11:29:08+09:00, 2014:02:25 11:29:08+09:00, 2014:02:25 11:30:47+09:00, 2014:02:25 11:32:49+09:00, 2014:02:25 17:15:49+09:00, 2014:02:25 17:15:49+09:00, 2014:02:26 09:47:02+09:00, 2014:02:26 09:47:09+09:00, 2014:02:26 09:49:24+09:00, 2014:02:26 09:49:25+09:00, 2014:02:26 10:03:36+09:00, 2014:02:26 10:03:36+09:00, 2014:02:26 10:10:12+09:00, 2014:02:26 10:10:12+09:00, 2014:02:26 10:19:50+09:00, 2014:02:26 11:22:11+09:00, 2014:02:26 11:22:11+09:00, 2014:02:26 11:24:24+09:00, 2014:02:26 11:24:36+09:00, 2014:02:26 11:24:51+09:00, 2014:02:26 11:27:53+09:00, 2014:02:26 11:33:57+09:00, 2014:02:26 13:53:28+09:00, 2014:02:26 14:30:55+09:00, 2014:02:26 15:26:32+09:00, 2014:02:26 15:26:32+09:00, 2014:02:26 15:53:06+09:00, 2014:02:26 15:53:06+09:00, 2014:02:26 15:55:31+09:00, 2014:02:26 16:04:46+09:00, 2014:02:26 16:13:49+09:00, 2014:02:26 16:14:25+09:00, 2014:02:26 16:17:44+09:00, 2014:02:26 16:17:45+09:00, 2014:02:26 16:33:21+09:00, 2014:02:26 16:33:39+09:00, 2014:02:26 16:37:23+09:00, 2014:02:26 16:38:28+09:00, 2014:02:26 16:41:41+09:00, 2014:02:26 16:56+09:00, 2014:02:26 17:07:02+09:00, 2014:02:26 17:07:14+09:00, 2014:02:26 17:07:29+09:00, 2014:02:26 17:07:50+09:00, 2014:02:26 17:12:18+09:00, 2014:02:26 17:12:19+09:00, 2014:02:26 17:23:38+09:00, 2014:02:27 08:50:54+09:00, 2014:02:27 08:54:32+09:00, 2014:03:18 15:09:30+09:00, 2014:03:18 15:09:36+09:00, 2014:03:18 15:16:16+09:00, 2014:04:18 09:48:34+09:00, 2014:04:18 09:48:38+09:00, 2014:04:18 09:58:02+09:00, 2014:04:18 09:58:02+09:00, 2014:04:18 14:58:12+09:00, 2014:05:22 10:48:47+09:00, 2014:05:22 10:48:54+09:00
History Software Agent          : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5
History Changed                 : /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata
Metadata Date                   : 2014:05:22 10:56:09+09:00
Creator Tool                    : Adobe InDesign CS5.5_J (7.5.3)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 9377 bytes, use -b option to extract), (Binary data 11439 bytes, use -b option to extract)
Doc Change Count                : 4353
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 40
EXIF Metadata provided by EXIF.tools

Navigation menu