Cct 04c
2014-09-05
: Pdf 196612-Attachment 196612-Attachment 784550 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 32
Download | |
Open PDF In Browser | View PDF |
“Made with pride in the USA” Catalog CCT-11A Fusing chart update Effective Date: June 10, 2011 Supercedes: CCT-10B MICRON INDUSTRIES CATALOG CCT-11A REPLACES CCT-10B Table of Contents THE MICRON EDGE - Warranty Transformer Selection Process Standards -UL/CSA -CUL -IEC Control Transformers Series 2 ImperviTRAN & ImperviTRAN -Connection Diagrams -Accessories Overcurrent Protection Tables (UPDATED) GlobalTRAN -Connection Diagrams Medium Voltage Power Supplies DINergy Power Supplies 2 3 4-5 6 8-13 14 15-17 18 19-24 25 26 27-29 LVGP -Overview 30 Notes 31 MICRON POWER DELIVERY THE MICRON EDGE While other manufacturers treat transformers as just one of a variety of products, transformers are THE major product focus for Micron This focus and resulting commitment to excellence, exemplified in our unprecedented 20-year warranty¹, has made Micron #1 with specifiers of transformers for over 30 years. ¹ 20 years applies to all 600 volt class Control Transformer product. LVGP and Medium Voltage are waranted for one year, Power Supplies for five. 3 MICRON POWER DELIVERY TRANSFORMER SELECTION PROCESS Determining Inrush and Voltage Requirements Selecting a transformer for industrial control circuit applications requires knowledge of the following terms: INRUSH VA is the product of the load voltage (V) multiplied by the current (A) that is required during startup. It is calculated by adding the inrush VA requirements of all devices (contactors, timers, relays, pilot lights, solenoids, etc.), which will be energized together. Inrush VA requirements are best obtained from the component manufacturer. SEALED VA also called Steady State VA, is the product of the load voltage (V) multiplied by the current (A) that is required to operate the circuit after initial start-up or under normal operating conditions. It is calculated by adding the sealed VA requirements of all electrical components of the circuit that will be energized at any given time. Sealed VA requirements are best obtained from the component manufacturer. 4 PRIMARY VOLTAGE is the voltage available from the electrical distribution system and its operational frequency, which is connected to the transformer supply voltage (H) terminals. SECONDARY VOLTAGE is the voltage required for load operation, which is connected to the transformer load voltage (X) terminals. Once the circuit variables have been determined, transformer selection is a simple 5-step process as follows: 1. Determine the Application Inrush VA by using the following industry accepted formula. Application Inrush VA = (INRUSH VA)² + (SEALED VA)² 2. Refer to the Regulation Data Chart. If the primary voltage is basically stable and does not vary by more than 5% from nominal, the MICRON POWER DELIVERY REGULATION DATA CHART Transformer Inrush VA at 20% Power factor VA Rating NEMA / IEC NEMA / IEC NEMA / IEC 95% Sec. 90% Sec. 85% Sec. Voltage Voltage Voltage 25¹ 100 / ---130 / --150 / --50¹ 170 / 190 200 / 220 240 / 270 75¹ 310 / 350 410 / 460 540 / 600 100¹ 370 / 410 540 / 600 730 / 810 150² 780 / 850 930 / 1030 1150 / 1270 200² 810 / 900 1150 / 1270 1450 / 1600 250² 1400 / 1540 1900 / 2090 2300 / 2530 300² 1900 / 2090 2700 / 2970 3850 / 4240 350² 3100 / 3410 3650 / 4020 4800 / 5280 500² 4000 / 4400 5300 / 5830 7000 / 7700 750² 8300 / 9130 11000 / 12100 14000 / 15400 1000² 15000 / 16500 21000 / 23000 27000 / 29500 1000³ 9000 / 9900 13000 / 14300 18500 / 20300 1500³ 10500 / 11500 15000 / 16500 20500 / 22500 2000³ 17000 / 18900 25500 / 27300 34000 / 36400 3000³ 24000 / 25700 36000 / 38500 47500 / 50200 5000³ 55000 / 58800 92500 / 98900 115000 / 122000 To comply with NEMA standards, which require all magnetic devices to operate successfully at 85% of rated voltage, the 90% secondary column is most often used in selecting a transformer. No comparable requirement is available for IEC. ¹ For units with class 105° C insulation system. ² For units with class 130° C insulation system. ³ For units with class 180° C insulation system 5 MICRON POWER DELIVERY INDUSTRY AND INTERNATIONAL STANDARDS Micron offers a broad line of standard transformers, each made with the finest materials and workmanship. Laminations of high-grade silicon steel assure optimum performance and the finest quality copper magnet wire assures efficient operation. Insulation materials are of the highest rating available for the temperature class and mounting brackets of heavy gauge steel add strength and stability. All are UL 506 listed (File # E46323) and either C-UL or CSA certified (File # LR27533) and meet NEMA and ANSI requirements. In response to the change in compliance standards for CE marking of industrial control transformers as required by IEC/EN guidelines, Micron has introduced new GlobalTRAN models in compliance with EN61558-2. This new IEC/EN standard replaces the previous IEC/EN 60742 standard for control power transformers that expired on December 31, 2003. The Micron design engineering department has produced 61558-2 compliant designs that permit the customer to retain mounting layouts used for the previous Micron 60742 designs. GlobalTRAN® products carry the CE mark, certifying 100% compliance with requirements of EN61558 for Non-Short Circuit Proof Isolating Transformers. GlobalTRAN control transformers feature touch-proof terminals, utilizing either Micron's SafeTouch terminal covers or a touch-proof terminal block, and meet true IP-20 or IP-00 terminal protection ratings as defined by IEC-529. Of course, all GlobalTRAN products carry either UL listing and CSA certification or cUL. GlobalTRAN is the most reliable and versatile control transformer in the industry today. DINergy™ products are designed to meet the most stringent international specifications for safety and EMI; and are designed to compact dimensions. All carry C-UL certification to UL60950 and UL508 plus the CE mark signifying certification to EN60950, EN 55022B, EN 61000-3-2 and IEC610004-2, 3, 4, 5, 6, 8, 11. ImperviPOWER 67™ products are designed to meet the most stringent international specifications; and are designed to compact dimensions. All carry certification to UL60950, CSA 22.2, EN60950, EN 55011, EN 6100-6, EN6000-6-2, -4-2, -4-3, -4-4, -4-5, -4-6 and -4-11. 6 MICRON POWER DELIVERY IMPERVITRAN SIMPLY – THE MOST VERSATILE AVAILABLE ImperviTRAN's feature-laden Series 2 design. Developed to SEMS screw terminal strips as an integral part of the coil bobbin address ALL customer needs with a product designed in a highly efficient manner. ImperviTRAN designs span over 35 Allows bare wire and terminal connection methods Easily adaptable to slot, Phillips and hex driver tools years of market leadership. Robust physical support instead of “floating” terminal strips UL/CSA or C-UL Family Listing Absolute flexibility of design for 600 volt class product Fully encapsulated coil Tough environment-proof construction Integral accessory mounting plate on transformer top Allows field modification to block-style primary fusing Reduces SKU count for fused/non-fused applications Provides mounting platform for additional items (DIN Rail) Eases wire routing around the transformer Standard strap brackets or optional mounting plate Fusion-welded coil terminations instead of solder joints Features a superior weld result for vibration-resistant stability Eliminates cold solder joint breakage, improves conductivity Offers common mounting template across a wide range of voltages Provides a lead-free RoHS compliant construction Alternate plates available for OEM volumes Face-on terminal labels with large schematic indicators IP-20 cover kits available Terminal designations clearly visible to the installer and technician Quickly convertible to an IP-20 safety level Indicators aligned with terminal screws for clarity CONTROL TRANSFORMERS GENERAL SPECIFICATIONS: STYLE: SERIES 2 IMPERVITRAN STYLE: IMPERVITRAN (NOT SERIES 2) APPROVALS: UL/Cul FILE# E46323 APPROVALS: UL LISTED FILE# E46323/ CSA APPROVED FILE# LR27533 TEMP CLASS: 105°C/130°C TEMP CLASS: 105°C/130°C/180°C VA SIZES: 50-1500 VA SIZES: 1000-5000 TERMINAL TORQUE: SUFFIX DESCRIPTION: ALL IMPERVITRAN PRODUCT "K" IN SUFFIX DENOTES INSTALLED SECONDARY FUSE CLIPS ≤30A: 20 INCH-POUNDS "R" IN SUFFIX DENOTES INSTALLED CLASS "CC" PRIMARY FUSE BLOCK TWO LETTER SUFFIX = TEMP CLASS 105C >30A: 30 INCH-POUNDS THREE LETTER SUFFIX ENDING "F" = TEMP CLASS 130C THREE LETTER SUFFIX ENDING "H" = TEMP CLASS 180C CATALOG CATALOG CATALOG NUMBER NUMBER NUMBER GROUP "A" GROUP "C" GROUP "F" VOLTAGE: VOLTAGE: VOLTAGE: PRI: 220x440, 230x460, 240x480 PRI: 120x240 PRI: 208/277 SEC: 110/115/120 SEC: 24 SEC: 120 VA AMPS VA AMPS VA AMPS B050BTZ13JK 50 0.43 B050LP7JK 50 2.08 B050MQ15XK 50 0.42 B050BTZ13RB B050LP7RB B050MQ15RK B075BTZ13JK 75 0.65 B075LP7JK 75 3.13 B075MQ15XK 75 0.63 B075BTZ13RB B075LP7RB B075MQ15RK B100BTZ13JK 100 0.87 B100LP7JK 100 4.17 B100MQ15XK 100 0.83 B100BTZ13RB B100LP7RB B100MQ15RK B150BTZ13JKF 150 1.30 B150LP7JKF 150 6.25 B150MQ15XKF 150 1.25 B150BTZ13RBF B150LP7RBF B150MQ15RKF B200BTZ13JKF 200 1.74 B200LP7JKF 200 8.33 B200MQ15XKF 200 1.67 B200BTZ13RBF B200LP7RBF B200MQ15RKF B250BTZ13JKF 250 2.17 B250LP7JKF 250 10.42 B250MQ15XKF 250 2.08 B250BTZ13RBF B250LP7RBF B250MQ15RKF B300BTZ13JKF 300 2.61 B300LP7JKF 300 12.50 B300MQ15XKF 300 2.50 B300BTZ13RBF B300LP7RBF B300MQ15RKF B350BTZ13JKF 350 3.04 B350LP7JKF 350 14.58 B350MQ15XKF 350 2.92 B350BTZ13RBF B350LP7RBF B350MQ15RKF B500BTZ13JKF 500 4.35 B500LP7JKF 500 20.83 B500MQ15XKF 500 4.17 B500BTZ13RBF B500LP7RBF B500MQ15RKF B750BTZ13JKF 750 6.52 B750LP7JKF 750 31.25 B750MQ15XKF 750 6.25 B750BTZ13RBF B750LP7RBF B750MQ15RKF B1K0BTZ13JKF 1000 8.70 B1K0BTZ13RBF GROUP "G" B1K5BTZ13JKF 1500 13.04 VOLTAGE: B1K5BTZ13RBF PRI: 208/230/460 B2K0BTZ13JKH 2000 17.39 SEC: 115 B2K0BTZ13RBH B050MBT13XK 50 0.43 B3K0BTZ13JXH 3000 26.09 B050MBT13RK B5K0BTZ13JXH 5000 43.48 B075MBT13XK 75 0.65 B075MBT13RK GROUP "B" GROUP "E" B100MBT13XK 100 0.87 VOLTAGE: VOLTAGE: B100MBT13RK PRI: 240x480 PRI: 550/575/600 B150MBT13XKF 150 1.30 SEC: 24 SEC: 110/115/120 B150MBT13RKF B050PU7JK 50 2.08 B050WZ13XK 50 0.43 B200MBT13XKF 200 1.74 B050PU7RB B050WZ13RK B200MBT13RKF B075PU7JK 75 3.13 B075WZ13XK 75 0.65 B250MBT13XKF 250 2.17 B075PU7RB B075WZ13RK B250MBT13RKF B100PU7JK 100 4.17 B100WZ13XK 100 0.87 B300MBT13XKF 300 2.61 B100PU7RB B100WZ13RK B300MBT13RKF B150PU7JKF 150 6.25 B150WZ13XKF 150 1.30 B350MBT13XKF 350 3.04 B150PU7RBF B150WZ13RKF B350MBT13RKF B200PU7JKF 200 8.33 B200WZ13XKF 200 1.74 B500MBT13XKF 500 4.35 B200PU7RBF B200WZ13RKF B500MBT13RKF B250PU7JKF 250 10.42 B250WZ13XKF 250 2.17 B750MBT13XKF 750 6.52 B250PU7RBF B250WZ13RKF B750MBT13RKF B300PU7JKF 300 12.50 B300WZ13XKF 300 2.61 B1K0MBT13XKF 1000 8.70 B300PU7RBF B300WZ13RKF B1K0MBT13RKF B350PU7JKF 350 14.58 B350WZ13XKF 350 3.04 B1K5MBT13XKF 1500 13.04 B350PU7RBF B350WZ13RKF B1K5MBT13RKF B500PU7JKF 500 20.83 B500WZ13XKF 500 4.35 B2K0MBT13XKH 2000 17.39 B500PU7RBF B500WZ13RKF B2K0MBT13RKH B750PU7JKF 750 31.25 B750WZ13XKF 750 6.52 B3K0MBT13XXH 3000 26.09 B750PU7RBF B750WZ13RKF B5K0MBT13XXH 5000 43.48 8 MICRON POWER DELIVERY STYLE: SERIES 2 IMPERVITRAN CATALOG NUMBER GROUP "H" VOLTAGE: PRI: 230/460/575 SEC: 95/115 VA AMPS B050BTW37XX 50 0.53/0.44 B050BTW37RX B075BTW37XX 75 0.79/0.65 B075BTW37RX B100BTW37XX 100 1.05/0.87 B100BTW37RX B150BTW37XXF 150 1.58/1.30 B150BTW37RXF B200BTW37XXF 200 2.11/1.74 B200BTW37RXF B250BTW37XXF 250 2.63/2.17 B250BTW37RXF B300BTW37XXF 300 3.16/2.61 B300BTW37RXF B350BTW37XXF 350 3.68/3.04 B350BTW37RXF B500BTW37XXF 500 5.26/4.35 B500BTW37RXF B750BTW37XXF 750 7.89/6.52 B750BTW37RXF B1K0BTWZ37XKH 1000 10.53/8/70 B1K0BTWZ37RKH B1K5BTWZ37XKH 1500 15.79/13.04 B1K5BTWZ37RKH B2K0BTWZ37XKH 2000 21.05/17.39 B2K0BTWZ37RKH B3K0BTWZ37XXH 3000 31.58/26.09 B5K0BTWZ37XXH 5000 52.63/43.48 GROUP "I" VOLTAGE: PRI: 380/400/415 SEC: 110x220 VA AMPS B050RFD34XJ 50 0.46/0.23 B050RFD34RJ B075RFD34XJ 75 0.68/0.34 B075RFD34RJ B100RFD34XJ 100 0.91/0.46 B100RFD34RJ B150RFD34XJF 150 1.37/0.69 B150RFD34RJF B200RFD34XJF 200 1.82/0.91 B200RFD34RJF B250RFD34XJF 250 2.28/1.14 B250RFD34RJF B300RFD34XJF 300 2.72/1.36 B300RFD34RJF B350RFD34XJF 350 3.18/1.59 B350RFD34RJF B500RFD34XJF 500 4.55/2.27 B500RFD34RJF B750RFD34XJF 750 6.82/3.41 B750RFD34RJF 9 CONTROL TRANSFORMERS STYLE: IMPERVITRAN (NOT SERIES 2) CATALOG NUMBER GROUP "J" VOLTAGE: PRI: 208/230/460 SEC: 24/115 VA AMPS B050-2000-1 50 2.08/0.44 B050-2000-8 B075-2001-1 75 3.13/0.65 B075-2001-8 B100-2002-1 100 4.17/0.87 B100-2002-8 B150-2003-1F 150 6.25/1.30 B150-2003-8F B200-2004-1F 200 8.33/1.74 B200-2004-8F B250-2005-1F 250 10.42/2.17 B250-2005-8F B300-2006-1F 300 12.50/2.61 B300-2006-8F B350-2007-1F 350 14.58/3.04 B350-2007-8F B500-2008-1F 500 20.84/4.35 B500-2008-8F B750-2009-1F 750 31.3/6.5 B750-2009-8F B1K0-2010-1F 1000 41.7/8.7 B1K0-2010-8F CATALOG NUMBER GROUP "K" VOLTAGE: PRI: 240x480 SEC: 120x240 VA AMPS B050PU1519JJ 50 0.42/0.21 B050PU1519RR B075PU1519JJ 75 0.63/0.31 B075PU1519RR B100PU1519JJ 100 0.83/0.42 B100PU1519RR B150PU1519JJF 150 1.25/0.63 B150PU1519RRF B200PU1519JJF 200 1.67/0.83 B200PU1519RRF B250PU1519JJF 250 2.08/1.04 B250PU1519RRF B300PU1519JJF 300 2.50/1.25 B300PU1519RRF B350PU1519JJF 350 2.92/1.46 B350PU1519RRF B500PU1519JJF 500 4.17/2.08 B500PU1519RRF B750PU1519JJF 750 6.25/3.12 B750PU1519RRF GROUP "J" USE SERIES 2 GROUP "J" (ABOVE) FOR NEW APPLICATIONS! VOLTAGE: PRI: 208/230/460 SEC: 24/115 VA AMPS B050MBT713XK 50 2.08/0.44 B050MBT713RK B075MBT713XK 75 3.13/0.65 B075MBT713RK B100MBT713XK 100 4.17/0.87 B100MBT713RK B150MBT713XKF 150 6.25/1.30 B150MBT713RKF B200MBT713XKF 200 8.33/1.74 B200MBT713RKF B250MBT713XKF 250 10.42/2.17 B250MBT713RKF B300MBT713XKF 300 12.50/2.61 B300MBT713RKF B350MBT713XKF 350 14.58/3.04 B350MBT713RKF B500MBT713XKF 500 20.84/4.35 B500MBT713RKF MICRON POWER DELIVERY CONTROL TRANSFORMERS STYLE: IMPERVITRAN (NOT SERIES 2) STYLE: SERIES 2 IMPERVITRAN CATALOG NUMBER GROUP "L" B050-0482-1 B050-0482-8 B100-0483-1 B100-0483-8 B150-0484-1F B150-0484-8F B250-0485-1F B250-0485-8F B350-0486-1F B350-0486-8F B500-0487-1F B500-0487-8F B750-0488-1F B750-0488-8F VOLTAGE: PRI: 208-600 SEC: 85-130 VA AMPS 50 0.38 100 0.77 150 1.15 250 1.92 350 2.69 500 3.85 750 5.77 GROUP "M" VOLTAGE: PRI: 240x480, 230x460, 220x440 SEC: 120x240, 115x230, 110x220 VA AMPS B1K0-0500-3F 1000 8.70/4.35 B1K5-0501-3H 1500 13.04/6.52 B2K0-0502-3H 2000 17.39/8.70 B3K0-0503-3H 3000 26.09/13.04 B5K0-0504-3H 5000 43.48/21.74 GROUP "N" VOLTAGE: PRI: 240, 347, 380 SEC: 120x240 VA AMPS B1K0-0321-3F 1000 8.33/4.17 B1K5-0322-3H 1500 12.50/6.25 B2K0-0323-3H 2000 16.67/8.33 B3K0-0324-3H 3000 25.00/12.50 B5K0-0325-3H 5000 41.67/20.83 GROUP "P" VOLTAGE: PRI: 120x240 SEC: 120x240 VA B050LP1519JJ 50 B100LP1519JJ 100 B150LP1519JJF 150 B250LP1519JJF 250 B350LP1519JJF 350 B500LP1519JJF 500 B750LP1519JJF 750 10 AMPS 0.42/0.21 0.83/0.42 1.25/0.63 2.08/1.04 2.92/1.46 4.17/2.08 6.25/3.12 MICRON POWER DELIVERY DIMENSIONAL DATA NOTE: SERIES 2 AND IMPERVITRAN TERMINAL BLOCK CAN HAVE 4 OR 6 TERMINALS AS NOTED. PRIMARY FUSE BLOCK ADDS 1.375" (35MM) TO "C" DIMENSION. A D C B E NOTE: DIMENSION"C"' IS A MAXIMUM DIMENSION. IF SECONDARY FUSE CLIPS ARE (MATCHED DIMENSIONS) CATALOG GROUPS INCLUDED IN DESIGN, DEDUCT A MAXIMUM OF 0.50 (12.7MM) TO REMOVE. A, B, C, E, F, G*, H*, I, K, P ALWAYS REQUEST CURRENT FACTORY DRAWING FOR FINAL REFERENCE. VOLTAGE GROUPS BTZ13, PU7, LP7, WZ13, MQ15, DIMENSIONS INCHES/MM MBT13, BTW37, RFD34, PU1519, A B C D E LP1519 SERIES 2 (MAX) ALL VERSIONS MAXIMUM CENTERS VA IN MM IN MM IN MM IN MM IN MM 50 4-TERM 3.78 96 3.00 76 3.14 79 1.96 50 2.50 64 75 4-TERM 4.03 102 3.00 76 3.14 79 2.42 62 2.50 64 100 4-TERM 4.03 102 3.38 86 3.46 86 2.42 62 2.82 71 150 4-TERM 4.03 102 3.75 95 3.77 96 2.82 71 3.13 79 200 4-TERM 4.38 111 4.50 114 4.40 112 2.42 62 3.75 95 250 4-TERM 4.38 111 4.50 114 4.40 112 2.82 71 3.75 95 300 4-TERM 4.75 121 4.50 114 4.40 112 3.18 81 3.75 95 350 4-TERM 4.75 121 4.50 114 4.40 112 3.75 95 3.75 95 500 6-TERM 6.11 155 5.25 133 5.14 131 3.88 99 4.38 111 750 6-TERM 7.61 193 5.25 133 5.14 131 5.38 137 4.38 111 * GROUP "G" MATCHES IN 75, 150 & 250VA. G 50 4-TERM 3.78 96 3.00 76 3.14 79 2.21 56 2.50 64 100 4-TERM 4.00 102 3.38 86 3.46 86 2.62 67 2.82 71 200 4-TERM 4.38 111 4.50 114 4.40 112 2.82 71 3.75 95 300 4-TERM 4.75 121 4.50 114 4.40 112 3.75 95 3.75 95 350 4-TERM 5.75 146 4.50 114 4.40 112 4.72 120 3.75 95 500 6-TERM 6.11 155 5.25 133 5.14 131 4.38 111 4.38 111 750 6-TERM 7.61 193 5.25 133 5.14 131 5.87 149 4.38 111 * GROUP "H" MATCHES IN 200, 250, 300 & 500VA H 50 4-TERM 4.03 102 3.00 76 2.72 69 2.20 56 2.50 64 75 4-TERM 4.53 115 3.00 76 2.72 69 2.62 67 2.50 64 100 4-TERM 4.03 102 3.75 95 3.36 85 2.82 71 3.13 79 150 4-TERM 4.53 115 3.75 95 3.36 85 3.18 81 3.75 95 350 4-TERM 5.00 127 4.50 114 3.97 101 3.75 95 3.75 95 750 6-TERM 8.11 206 5.25 133 4.63 118 5.87 149 4.38 111 APPROX WEIGHT LBS 3.00 4.00 5.20 6.00 8.00 10.00 12.00 14.00 16.00 28.00 3.50 5.70 7.00 11.00 13.00 15.00 28.00 3.50 4.50 6.00 7.70 16.50 28.00 DIAGRAMS BELOW DEPICT INSTALLED PRIMARY FUSING OPTION. DIAGRAMS DEPICT UNITS 500VA AND UP. 11 MICRON POWER DELIVERY DIMENSIONAL DATA (KVA SIZES) KVA SIZES CAN EITHER BE SERIES 2 OR IMPERVITRAN DIAGRAMS DEPICT SERIES 2 DESIGN. NOTE: SERIES 2 AND IMPERVITRAN TERMINAL BLOCK CAN HAVE 4 OR 6 TERMINALS AS NOTED. PRIMARY FUSE BLOCK ADDS 1.375" (35MM) TO "C" DIMENSION. A CATALOG (VOLTAGE) GROUP A (BTZ13) VA 1000 6-TERM 1500 6-TERM 2000 6-TERM 3000 6-TERM 5000 6-TERM D C B E NOTE: DIMENSION"C"' IS A MAXIMUM DIMENSION. IF SECONDARY FUSE CLIPS ARE INCLUDED IN DESIGN, DEDUCT A MAXIMUM OF 0.50 (12.7MM) TO REMOVE. ALWAYS REQUEST CURRENT FACTORY DRAWING FOR FINAL REFERENCE. DIMENSIONS INCHES/MM A B C D E (MAX) MAXIMUM CENTERS IN MM IN MM IN MM IN MM IN MM 6.11 155 6.75 172 6.30 160 3.91 99 6.13 156 8.11 206 6.75 172 6.32 161 6.12 155 6.13 156 7.75 197 6.75 172 6.28 160 4.97 126 6.13 156 8.06 205 9.00 229 7.50 191 5.25 133 7.50 191 10.38 264 9.00 229 7.50 191 7.56 192 7.50 191 APPROX WEIGHT LBS 30.50 50.10 46.00 55.90 84.40 G (MBT13) 1000 6-TERM 1500 6-TERM 2000 6-TERM 3000 6-TERM 5000 6-TERM 7.44 8.50 8.13 8.56 10.00 189 216 207 217 254 6.38 6.75 6.75 9.00 9.00 162 172 172 229 229 5.42 5.73 5.75 7.50 7.50 138 146 146 191 191 5.06 6.09 5.25 5.75 7.56 129 155 133 146 192 5.31 6.13 6.13 7.50 7.50 135 156 156 191 191 37.00 53.90 42.00 64.50 97.00 H (BTWZ37) 1000 6-TERM 1500 6-TERM 2000 6-TERM 3000 6-TERM 5000 6-TERM 7.00 7.45 7.56 8.75 11.00 178 189 192 222 279 6.38 6.75 9.00 9.00 9.00 162 172 229 229 229 5.42 6.29 7.80 7.50 7.50 138 160 198 191 191 5.06 5.25 4.81 5.94 8.19 129 133 122 151 208 5.31 6.13 7.50 7.50 7.50 135 156 191 191 191 31.80 44.20 57.70 76.20 127.40 M 240/480 X 120/240 1000 4-TERM 1500 6-TERM 2000 6-TERM 3000 6-TERM 5000 6-TERM 7.00 7.00 7.75 8.06 10.00 178 178 197 205 254 5.25 6.75 6.75 9.00 9.00 133 172 172 229 229 4.25 5.75 5.73 7.50 7.50 108 146 146 191 191 5.38 4.25 4.97 5.25 7.19 137 108 126 133 183 4.38 6.13 6.13 7.50 7.50 111 156 156 191 191 26.30 31.00 46.00 56.00 85.40 N 240,347,380 X 120/240 1000 6-TERM 1500 6-TERM 2000 6-TERM 3000 6-TERM 5000 6-TERM 7.38 8.13 8.88 8.50 10.38 187 207 226 216 264 6.38 6.38 6.75 9.00 9.00 162 162 172 229 229 5.44 5.44 5.75 7.50 7.50 138 138 146 191 191 5.06 5.06 6.13 5.69 7.56 129 129 156 146 192 5.31 5.31 6.13 7.50 7.50 135 135 156 191 191 29.00 33.30 50.00 74.00 110.00 DIAGRAMS DEPICT IMPERVITRAN DESIGN. 12 MICRON POWER DELIVERY DIMENSIONAL DATA NOTE: SERIES 2 AND IMPERVITRAN TERMINAL BLOCK CAN HAVE 4 OR 6 TERMINALS AS NOTED. PRIMARY FUSE BLOCK ADDS 1.375" (35MM) TO "C" DIMENSION. A CATALOG (VOLTAGE) GROUP OBSOLETE GROUP "J" ORIGINAL IMPERVITRAN P/N B050MBT713XK 4-TERM B075MBT713XK 4-TERM B100MBT713XK 4-TERM B150MBT713XKF 4-TERM B200MBT713XKF 4-TERM B250MBT713XKF 4-TERM B300MBT713XKF 4-TERM B350MBT713XKF 4-TERM B500MBT713XKF 4-TERM J SERIES 2 B050-2000-1 B075-2001-1 B100-2002-1 B150-2003-1F B200-2004-1F B250-2005-1F B300-2006-1F B350-2007-1F B500-2008-1F B750-2009-1F B1K0-2010-1F D C B E NOTE: DIMENSION"C"' IS A MAXIMUM DIMENSION. IF SECONDARY FUSE CLIPS ARE INCLUDED IN DESIGN, DEDUCT A MAXIMUM OF 0.50 (12.7MM) TO REMOVE. ALWAYS REQUEST CURRENT FACTORY DRAWING FOR FINAL REFERENCE. DIMENSIONS INCHES/MM A B C D E SERIES 2 (MAX) ALL VERSIONS MAXIMUM CENTERS IN MM IN MM IN MM IN MM IN MM 3.50 89 3.00 76 3.14 79 2.25 57 2.50 64 3.50 89 3.38 86 3.44 87 2.44 62 2.82 71 3.63 92 3.75 95 3.78 96 2.44 62 3.13 79 4.00 102 3.75 95 3.78 96 3.19 81 3.13 79 4.38 111 4.50 114 4.40 112 3.00 76 3.75 95 4.38 111 4.50 114 4.40 112 3.75 95 3.75 95 5.19 132 5.25 133 5.14 131 3.88 99 4.38 111 5.00 127 5.25 133 5.14 131 3.88 99 4.38 111 5.50 140 5.25 133 5.14 131 5.38 137 4.38 111 APPROX WEIGHT LBS 3.40 4.80 5.90 8.00 9.80 12.00 14.00 15.00 18.00 4-TERM 4-TERM 4-TERM 4-TERM 4-TERM 4-TERM 4-TERM 6-TERM 6-TERM 6-TERM 6-TERM 4.53 4.53 4.53 5.03 4.38 4.75 6.11 6.11 7.11 7.11 8.13 115 115 115 128 111 121 155 155 181 181 207 3.00 3.75 3.75 3.75 4.50 4.50 5.25 5.25 5.25 6.75 6.75 76 95 95 95 114 114 133 133 133 172 172 3.14 3.78 3.78 3.78 4.40 4.40 5.14 5.14 5.14 6.30 5.73 79 96 96 96 112 112 131 131 131 160 146 2.82 2.82 3.00 3.19 3.00 3.75 3.88 3.88 5.38 4.97 6.13 71 71 76 81 76 95 99 99 137 126 156 2.50 3.13 3.13 3.13 3.75 3.75 4.38 4.38 4.38 6.13 6.13 64 79 79 79 95 95 111 111 111 156 156 3.40 4.80 5.90 8.00 9.80 12.00 14.00 15.00 18.00 38.60 48.40 L ORIGINAL IMPERVITRAN B050-0482-1 6-TERM B100-0483-1 6-TERM B150-0484-1F 6-TERM B250-0485-1F 6-TERM B350-0486-1F 6-TERM B500-0487-1F 6-TERM B750-0488-1F 6-TERM 3.44 4.00 4.00 5.75 5.14 7.19 6.50 87 102 102 146 131 183 165 3.88 3.75 4.50 4.50 5.25 5.14 6.75 99 95 114 114 133 131 172 3.38 3.50 4.50 4.50 4.75 4.75 6.00 86 89 114 114 121 121 152 2.41 3.00 2.82 4.38 4.38 5.88 4.25 61 76 71 111 111 149 108 2.81 3.13 3.75 3.75 4.38 4.38 6.13 71 79 95 95 111 111 156 4.00 6.60 8.70 11.40 13.60 17.40 27.50 DIAGRAMS BELOW DEPICT INSTALLED PRIMARY FUSING OPTION. DIAGRAMS DEPICT UNITS 500VA AND UP. 13 MICRON POWER DELIVERY CONNECTION DIAGRAMS CONNECTION DIAGRAM: GROUP "A" CONNECTION DIAGRAM: GROUP "E" CONNECTION DIAGRAM: GROUP "H" 14 CONNECTION DIAGRAM: GROUP "B" CONNECTION DIAGRAM: GROUP "F" CONNECTION DIAGRAM: GROUP "C" CONNECTION DIAGRAM: GROUP "G" CONNECTION DIAGRAM: GROUP "I" CONNECTION DIAGRAM: GROUP "J" CONNECTION DIAGRAM: GROUP "K" CONNECTION DIAGRAM: GROUP "L" CONNECTION DIAGRAM: GROUP "M" CONNECTION DIAGRAM: GROUP "N" CONNECTION DIAGRAM: GROUP "P" MICRON POWER DELIVERY CONTROL TRANSFORMER ACCESSORIES CATALOG NUMBER APPROX. WEIGHT LBS KG TPTC-2001 TPTC-2002 TPTC-2006 IP-20 SAFETOUCH™ COVERS 10PACK 4TERM. 10PACK 6TERM. 10PACK UNIVERSAL PRI BLOCK 1.0 1.0 1.0 0.5 0.5 0.5 FKTP-1001 PRIMARY CL "CC" FUSE KIT 0.25 0.1 CL. "CC" PRI. OPTIONAL FACTORY INSTALLED FUSE HOLDERS P/N SUFFIX = RB, RK, RX, RJ, RR RY, RG, RL, RN, RC, -8 N/A *NON-REJECTION VERSION AVAILABLE ON ALL FACTORY INSTALLED PRIMARY FUSEBLOCK OPTIONS 1/4 X 1-1/4 SEC. 9/16 X 2 SEC. P/N SUFFIX = JQ, XQ P/N SUFFIX = JM, XM N/A N/A 514-1661-01C 514-1661-02C BULK FUSE CLIPS (2 NECESSARY) 13/32 X 1-1/2 (STD) (2 NECESSARY) 1/4 X 1-1/4 (OPT) N/A N/A 514-1650 514-1652 514-1620-02 BULK JUMPERS J-2 J-3 Flat N/A N/A N/A TRANSFORMER ACCESSORY INTERCHANGE MATRIX STANDARD SUFFIX JK, JKF, JKH XK, XKF, XKH XX, XXF, XXH XJ, XJF, XJH JJ, JJF, JJH JM, JMF, JMH XM, JMF, JMH JQ, JQF, JQH XQ, XQF, XQH JX, JXF, JXH -1, -1F, -1H 15 >> >> >> >> >> >> >> >> >> >> >> DUAL PRIMARY FUSED SUFFIX RB, RBF, RBH RK, RKF, RKH RX, RXF, RXH RJ, RJF, RJH RR, RRF, RRH RY, RYF, RYH RG, RGF, RGH RL RLF, RLH RN, RNF, RNH RC, RCF, RCH -8, -8F, -8H MICRON POWER DELIVERY PRIMARY FUSE KIT # FKTP-1001 SERIES 2 INSTRUCTIONS ON NEXT PAGE In addition to factory installed primary fusing capability Micron offers a primary fuse kit for ImperviTRAN and ValuTRAN intended for field installation. The primary fuse kit includes a 2-pole Class "CC" fuse block, instructions and all associated mounting hardware. Addititonally, this fuse block will fit most competitive units. To order this kit, use catalog number FKTP-1001. The primary fuse kit, when installed, will add a maximum of 11/16" to the transformer "A" dimension and 1-15/16" to the "C" dimension. Installed as indicated. 1. Loosen two outer screws on primary side of transformer. On 6 position shell leave 2 spaces open between brackets. 2. Capture mounting brackets and necessary leads under terminal screws and tighten. Recommended torque 30 in-lbs. 3. Affix fuse block to mounting bracket with supplied screws. 16 IP-20 COVER KIT # TPTC-2006 4. Remove two nuts or screws holding primary fuse block to transformer. On FKTP-1001 kits, perform step #5 prior to affixing block to brackets. 5. Install retaining clips in base of fuse block. Secure with nuts or screws as appropriate. 6, 6a. Install fuse in cover and snap cover in place. When installed cover cannot be removed without releasing tab from detent (6a). A tip of a pen will suffice. GLOBALTRAN ACCESSORIES A number of fusing accessories are available for the GlobalTRAN product line. Please contact Micron with your design requirements. MICRON POWER DELIVERY PRIMARY FUSE KIT # FKTP-1001 SERIES 2 INSTRUCTIONS In addition to factory installed primary fusing capability Micron offers a primary fuse kit for units with integral accessory mounting plate (#2) intended for field installation on all catalog standard SERIES 2 units. The primary fuse kit includes a 2-pole Class "CC" fuse block, instructions and all associated mounting hardware. To order this kit, use catalog number FKTP-1001. The primary fuse kit, when installed, will add a maximum of 1-3/8" to the "C" dimension. (as measured from the top of the plate) Installation instructions. 1. Connect one end of the 2 primary leads (#1) under the appropriate primary terminal screws. Secure screws to 16 in-lbs <500VA and 30 in-lbs 500VA and larger. 2. Insert locking clips (#4) oriented as shown into the fuse block (#3) pockets. Use caution in choosing screw length if locking clips are not used. 3. Attach clips and fuse block to accessory mounting plate (#2) using screws (#5). Recommended torque 16 in-lbs. 4. Insert fuses (not supplied) into fuse block followed by fuse fuse block covers (#6) (IF ORDERED) with lock slots (#6a) matching tip of the clips, as shown. Press down until cover locks. Refer to primary fuse chart for recommended fuses. Cover cannot be removed without releasing tab from detent (#6a). A tip of a pen will suffice. 5. Connect trhe other end of the 2 primary leads (#1) under the screws on each of the 2 poles on the fuse block (#3a) and secure to 20 inch-pounds. 6. Apply primary voltage to the opposite end of the fuse block (#3b). Additionally the mounting plate (#2) can be utilized to mount other accessories such as DIN rail. Use caution in choosing screw length. 17 MICRON POWER DELIVERY MICRON STANDARD FUSE DIMENSION IS 13/32 X 1-1/2 "MIDGET" FUSE MAXIMUM ACCEPTABLE RATING OF SECONDARY OVERCURRENT PROTECTION Secondary VA Rating Voltage 25 23 1-8/10 24 1-6/10 25 1-6/10 90 4/10 95 4/10 100 4/10 110 3/10 115 3/10 120 3/10 220 15/100 230 15/100 240 50 3-1/2 3-2/10 3-2/10 8/10 8/10 8/10 3/4 6/10 6/10 3/10 3/10 3/10 75 5 5 5 1-1/4 1-1/4 1-1/4 1-1/8 1 1 1/2 1/2 1/2 100 7 6-1/4 6-1/4 1-8/10 1-6/10 1-6/10 1-1/2 1-4/10 1-1/4 3/4 6/10 6/10 150 10 10 10 2-1/2 2-1/2 2-1/2 2-1/4 2 2 1-1/8 1 1 200 12 12 12 3-1/2 3-1/2 3-2/10 3 2-8/10 2-1/2 1-1/2 1-1/4 1-4/10 1-1/4 250 15 15 15 4-1/2 4 4 3-1/2 3-1/2 3-2/10 1-8/10 1-6/10 1-8/10 1-6/10 300 20 20 15 5 5 5 4-1/2 4 4 2-1/4 2 2 350 20 20 20 6-1/4 6 5-6/10 5 5 4-1/2 2-1/2 2-1/4 2-1/2 2-1/4 500 30 30 25 9 8 8 7-1/2 7 6-1/4 3-1/2 3-2/10 3-1/2 3-2/10 750 45 40 40 12 12 12 10 10 10 5-6/10 5 5 SECONDARY CURRENT = TRANSFORMER VA ÷ SECONDARY VOLTS If the rated secondary current is less than 9 amps, the maximum rating of the overcurrent device is 167%; 9 amps or more, the maximum rating of the overcurrent device is 125%. If 125% does not correspond to a standard fuse rating, the next highest standard rating may be used. Reference: NEC 430-72(c) exception #2; 450-3(b) 1 & 2; UL 508, 32.7; UL 845, 11.16 & 11.17. 18 MICRON POWER DELIVERY GLOBALTRAN GlobalTRAN products carry the CE mark, certifying 100% compliance with requirements of EN61558. Additionally all GlobalTRAN products are designed to deliver the full nameplate VA rating. Features and Benefits Lead -free solder joints Provides RoHS compliant construction Encapsulated from 25Va through 5KVa Establishes product similarity throughout the product range Fully encapsulated coil Tough environment-proof construction Eases wire routing around the transformer Full nameplate VA rating Eliminates guesswork Molded terminals as an integral part of the coil Largest standard voltage selection in the industry Easily adaptable to slot and Phillips driver tools Solves “availability problem” for many OEM design-in opportunities Robust physical support instead of “floating” terminal strips Both 4 and 6 terminals, or the combination, available IP-20 level covers installed Meets IEC-529 protection rating UL/CSA/cUL/CE Family Listing Absolute flexibility of special design capability for 600 volt class product CE CONTROL TRANSFORMERS GENERAL SPECIFICATIONS: STYLE: IMPERVITRAN APPROVALS: UL LISTED FILE# E46323/ CSA APPROVED FILE# LR27533, EN 61558-2-2 TEMP CLASS: 105°C/130°C/180°C VA SIZES: 50-5000 SUFFIX DESCRIPTION: TWO LETTER SUFFIX = TEMP CLASS 105C THREE LETTER SUFFIX ENDING "F" = TEMP CLASS 130C THREE LETTER SUFFIX ENDING "H" = TEMP CLASS 180C GLOBALTRAN: GROUP "A" CATALOG NUMBER VOLTAGE: PRI: 220x440, 230x460, 240x480 SEC: 110/115/120 VA AMPS B050-2001-GA 50 0.43 B075-2002-GA 75 0.65 B100-2003-GA 100 0.87 B150-2004-GAF 150 1.30 B200-2005-GAF 200 1.74 B250-2006-GAF 250 2.17 B300-2007-GAF 300 2.61 B350-2008-GAF 350 3.04 B500-2009-GAF 500 4.35 B750-2010-GAF 750 6.52 B1K0-2008-GAH 1000 8.70 B1K5-2009-GAH 1500 13.04 B2K0-2010-GAH 2000 17.39 B3K0-2011-GAH 3000 26.09 B5K0-2012-GAH 5000 45.45 GROUP "B" B050-2011-GA B075-2012-GA B100-2013-GA B150-2014-GAF B200-2015-GAF B250-2016-GAF B300-2017-GAF B350-2018-GAF B500-2019-GAF B750-2020-GAF B1K0-2028-GAF VOLTAGE: PRI: 240x480 SEC: 24 VA AMPS 50 2.08 75 3.13 100 4.17 150 6.25 200 8.33 250 10.42 300 12.50 350 14.58 500 20.83 750 31.25 1000 41.67 GROUP "C" B050-2021-GA B075-2022-GA B100-2023-GA B150-2024-GAF B200-2025-GAF B250-2026-GAF B300-2027-GAF B350-2028-GAF B500-2029-GAF B750-2030-GAF B1K0-2048-GAF 20 VOLTAGE: PRI: 120x240 SEC: 24 VA AMPS 50 2.08 75 3.13 100 4.17 150 6.25 200 8.33 250 10.42 300 12.50 350 14.58 500 20.83 750 31.25 1000 41.67 GLOBALTRAN: GROUP "D" CATALOG NUMBER VOLTAGE: PRI: 550/575/600 SEC: 110/115/120 VA B050-2041-GA 50 B075-2042-GA 75 B100-2043-GA 100 B150-2044-GAF 150 B200-2045-GAF 200 B250-2046-GAF 250 B300-2047-GAF 300 B350-2048-GAF 350 B500-2049-GAF 500 B750-2050-GAF 750 AMPS 0.43 0.65 0.87 1.30 1.74 2.17 2.61 3.04 4.35 6.52 GROUP "E" VOLTAGE: PRI: 380/400/415 SEC: 110x220 VA B050-2061-GA 50 B075-2062-GA 75 B100-2063-GA 100 B150-2064-GAF 150 B200-2065-GAF 200 B250-2066-GAF 250 B300-2067-GAF 300 B350-2068-GAF 350 B500-2069-GAF 500 B750-2070-GAF 750 AMPS .46/.23 .68/.34 .91/.46 1.37/.69 1.82/.91 2.28/1.14 2.72/1.36 3.18/1.59 4.55/2.27 6.82/3.41 GROUP "F" VOLTAGE: PRI: 208/230/460 SEC: 24/115 VA B050-2101-GA 50 B075-2102-GA 75 B100-2103-GA 100 B150-2104-GAF 150 B200-2105-GAF 200 B250-2106-GAF 250 B300-2107-GAF 300 B350-2108-GAF 350 B500-2109-GAF 500 B750-2110-GAF 750 B1K0-2188-GAH 1000 AMPS 2.08/.44 3.13/.65 4.17/.87 6.25/1.3 8.33/1.74 10.42/2.17 12.50/2.61 14.58/3.04 20.83/4.35 31.25/6.52 41.67/8.70 MICRON POWER DELIVERY CE CONTROL TRANSFORMERS GLOBALTRAN: GROUP "G" CATALOG NUMBER VOLTAGE: PRI: 380 SEC: 24 B050-2051-GA B075-2052-GA B100-2053-GA B150-2054-GAF B200-2055-GAF B250-2056-GAF B300-2057-GAF B350-2058-GAF B500-2059-GAF B750-2060-GAF VA 50 75 100 150 200 250 300 350 500 750 GLOBALTRAN: GROUP "I" CATALOG NUMBER VOLTAGE: PRI: 208/230/400/460/575 SEC: 24*/115/230 AMPS VA AMPS 2.08 B250-2263-GAF 250 10.4/2.2/1.1 3.13 B300-2264-GAF 300 12.5/2.6/1.3 4.17 B350-2265-GAF 350 14.6/3.0/1.5 6.25 B500-2266-GAF 500 20.8/4.3/2.2 8.33 B750-2267-GAF 750 31.3/6.5/3.3 10.42 B1K0-2268-GAH 1000 41.7/8.7/4.3 12.50 B1K5-2269-GAH 1500 13.04/6.52 14.58 B2K0-2270-GAH 2000 17.39/8.70 20.83 B3K0-2271-GAH 3000 26.09/13.04 31.25 B5K0-2272-GAH 5000 43.48/21.74 * 24 AVAILABLE THROUGH 1Kva GROUP "H" VOLTAGE: PRI: 208-600 SEC: 85-130 B250-2283-GAF B300-2284-GAF B350-2285-GAF B500-2286-GAF B750-2287-GAF B1K0-2288-GAH B1K5-2289-GAH B2K0-2290-GAH B3K0-2291-GAH 21 VA 250 300 350 500 750 1000 1500 2000 3000 AMPS 1.92 2.31 2.69 3.85 5.77 7.69 11.54 15.38 23.08 GROUP "J" VOLTAGE: PRI: 230/400/460/575 SEC: 24/115 VA B250-2243-GAF 250 B300-2244-GAF 300 B350-2245-GAF 350 B500-2246-GAF 500 B750-2247-GAF 750 B1K0-2248-GAH 1000 AMPS 10.4/2.2 12.5/2.6 14.6/3.0 20.8/4.3 31.3/6.5 41.7/8.7 MICRON POWER DELIVERY 4 TERMINAL A D CATALOG GROUPS P/N A A IN MM B050-2001-GA 3.38 86 B075-2002-GA 3.38 86 B100-2003-GA 3.38 86 B150-2004-GAF 3.75 95 B200-2005-GAF 3.75 95 B250-2006-GAF 4.00 102 B300-2007-GAF 4.38 111 B350-2008-GAF 4.88 124 B500-2009-GAF 5.13 130 B750-2010-GAF 7.00 178 B1K0-2008-GAH 6.63 168 B1K5-2009-GAH 7.31 186 B2K0-2010-GAH 8.13 203 B3K0-2011-GAH 8.06 202 B5K0-2012-GAH 10.00 250 22 B IN 3.00 3.38 3.75 4.50 4.50 4.50 4.50 5.25 5.25 5.25 6.38 6.75 6.75 9.00 9.00 MM 76 86 95 114 114 114 114 133 133 133 162 172 172 225 225 C B 6 TERMINAL E DIMENSIONS INCHES (MM) C D IN MM IN MM 3.00 76 2.44 61 3.25 83 2.44 61 3.50 89 2.44 61 4.00 102 2.44 61 4.00 102 2.81 71 4.00 102 3.19 81 4.00 102 3.75 95 4.50 114 3.38 86 4.50 114 4.38 111 4.50 114 5.88 149 5.50 140 3.75 95 6.00 152 5.00 127 6.00 152 5.25 133 8.00 200 5.25 133 8.00 200 7.19 183 E IN 2.50 2.81 3.13 3.75 3.75 3.75 3.75 4.38 4.38 4.38 5.31 6.13 6.13 7.50 7.50 MM 64 71 79 95 95 95 95 111 111 111 135 156 156 191 191 APPROX WEIGHT LBS 3.4 4.8 5.9 8.5 10.0 11.0 13.0 15.0 20.0 29.8 35.0 40.0 45.0 65.2 104.8 B B050-2011-GA B075-2012-GA B100-2013-GA B150-2014-GAF B200-2015-GAF B250-2016-GAF B300-2017-GAF B350-2018-GAF B500-2019-GAF B750-2020-GAF B1K0-2028-GAF 3.38 3.38 3.38 4.00 3.75 4.00 4.38 4.50 5.13 7.00 7.00 86 86 86 102 95 102 111 114 130 178 178 3.00 3.38 3.75 4.50 4.50 4.50 4.50 5.25 5.25 5.25 6.38 76 86 95 114 114 114 114 133 133 133 162 3.00 3.25 3.50 4.00 4.00 4.00 4.00 4.50 4.50 5.00 6.00 76 83 89 102 102 102 102 114 114 127 152 2.19 2.19 2.44 2.44 2.81 3.19 3.75 3.38 3.88 5.38 3.75 56 56 61 62 71 81 95 86 99 137 95 2.50 2.81 3.13 3.75 3.75 3.75 3.75 4.38 4.38 4.38 5.31 64 71 80 95 95 95 95 111 111 111 135 3.4 4.2 5.9 8.5 10.0 11.0 13.2 14.9 19.2 28.1 30.0 C B050-2021-GA B075-2022-GA B100-2023-GA B150-2024-GAF B200-2025-GAF B250-2026-GAF B300-2027-GAF B350-2028-GAF B500-2029-GAF B750-2030-GAF B1K0-2048-GAF 3.38 3.38 3.38 3.75 3.75 4.00 4.38 4.50 5.13 7.00 7.00 86 86 86 95 95 102 111 114 130 178 178 3.00 3.38 3.75 4.50 4.50 4.50 4.50 5.25 5.25 5.25 6.38 76 86 95 114 114 114 114 133 133 133 162 3.00 3.25 3.50 4.00 4.00 4.00 4.00 4.50 4.50 4.50 6.00 76 83 89 102 102 102 102 114 114 114 152 2.19 2.19 2.44 2.44 2.81 3.19 3.75 3.38 3.88 5.88 3.75 55 56 61 61 70 81 95 86 99 149 95 2.50 2.81 3.13 3.75 3.75 3.75 3.75 4.38 4.38 4.38 5.31 64 71 79 95 95 95 95 111 111 111 135 3.4 4.2 5.9 8.5 10.0 11.0 13.2 14.9 19.2 29.8 31.0 D B050-2041-GA B075-2042-GA B100-2043-GA B150-2044-GAF B200-2045-GAF B250-2046-GAF B300-2047-GAF B350-2048-GAF B500-2049-GAF B750-2050-GAF 3.38 3.38 3.38 3.75 3.75 4.00 4.38 4.50 5.13 7.00 86 86 86 95 95 102 111 114 130 178 3.00 3.38 3.75 4.50 4.50 4.50 4.50 5.25 5.25 5.25 76 86 95 114 114 114 114 133 133 133 3.00 3.25 3.50 4.00 4.00 4.00 4.00 4.50 4.50 4.50 76 83 89 102 102 102 102 114 114 114 2.44 2.44 2.44 2.44 3.00 3.19 3.75 3.38 4.38 5.38 61 61 61 61 76 81 95 86 111 137 2.50 2.81 3.13 3.75 3.75 3.75 3.75 4.38 4.38 4.38 64 71 80 95 95 95 95 111 111 111 3.4 4.8 5.9 8.5 10.0 11.0 13.0 15.0 20.0 28.0 MICRON POWER DELIVERY 4 TERMINAL A D CATALOG GROUPS P/N A E IN MM B050-2061-GA 3.38 86 B075-2062-GA 3.38 86 B100-2063-GA 3.38 86 B150-2064-GAF 3.75 95 B200-2065-GAF 3.75 95 B250-2066-GAF 4.00 102 B300-2067-GAF 4.38 111 B350-2068-GAF 4.75 121 B500-2069-GAF 5.13 130 B750-2070-GAF 7.00 178 F B050-2101-GA B075-2102-GA B100-2103-GA B150-2104-GAF B200-2105-GAF B250-2106-GAF B300-2107-GAF B350-2108-GAF B500-2109-GAF B750-2110-GAF B1K0-2188-GAH 23 B IN 3.00 3.38 3.75 4.50 4.50 4.50 4.50 4.50 5.25 5.25 MM 76 86 95 114 114 114 114 114 133 133 C B 6 TERMINAL E DIMENSIONS INCHES (MM) C D IN MM IN MM 3.00 76 2.44 61 3.50 89 2.44 61 3.50 89 2.44 61 4.00 102 2.44 61 4.00 102 3.00 76 4.00 102 3.19 81 4.00 102 3.75 95 4.00 102 3.75 95 4.50 114 4.38 111 4.50 114 5.88 149 E IN 2.50 2.81 3.13 3.75 3.75 3.75 3.75 3.75 4.38 4.38 MM 64 71 79 95 95 95 95 95 111 111 APPROX WEIGHT LBS 3.4 4.8 5.9 8.5 10.0 11.0 13.0 15.0 20.0 27.0 3.38 3.38 3.63 3.75 4.38 4.75 4.88 4.88 5.63 6.63 7.06 86 86 92 95 111 121 124 124 143 168 179 3.00 3.38 3.75 4.50 4.50 4.50 5.25 5.25 5.25 6.38 6.38 76 86 95 114 114 114 133 133 133 162 162 3.25 3.50 3.50 4.00 4.00 4.00 4.50 4.50 4.50 6.00 6.00 83 89 89 102 102 102 114 114 114 152 152 2.25 2.44 3.19 2.81 3.44 3.75 3.88 3.88 5.88 5.06 5.06 56 61 81 71 87 95 99 99 149 129 129 2.81 3.13 3.13 3.75 3.75 3.75 4.38 4.38 4.38 5.31 5.31 71 79 79 95 95 95 111 111 111 111 135 4.2 5.9 7.9 10.0 12.8 14.0 16.8 19.2 29 29.8 30.2 G B050-2051-GA B075-2052-GA B100-2053-GA B150-2054-GAF B200-2055-GAF B250-2056-GAF B300-2057-GAF B350-2058-GAF B500-2059-GAF B750-2060-GAF 3.38 3.38 3.38 3.63 3.75 4.00 4.38 4.50 5.13 7.00 86 86 86 91 95 102 111 114 130 178 3.00 3.38 3.75 3.75 4.50 4.50 4.50 5.25 5.25 5.25 76 86 95 95 114 114 114 133 133 133 3.00 3.25 3.50 3.50 4.00 4.00 4.00 4.50 4.50 4.50 76 83 89 89 102 102 102 114 114 114 2.19 2.19 2.44 3.00 2.81 3.19 3.75 3.88 3.88 5.88 55 56 61 61 70 81 95 99 99 149 2.50 2.81 3.13 3.13 3.75 3.75 3.75 4.38 4.38 4.38 64 71 79 79 95 95 95 111 111 111 3.5 4.2 5.9 9.6 11.3 13.2 14.9 19.2 29.8 H B250-2283-GAF B300-2284-GAF B350-2285-GAF B500-2286-GAF B750-2287-GAF B1K0-2288-GAH B1K5-2289-GAH B2K0-2290-GAH B3K0-2291-GAH 4.25 4.75 5.00 5.50 7.38 7.00 7.75 7.63 8.56 108 121 127 140 187 178 199 194 217 4.50 4.50 4.50 5.25 5.25 6.38 6.75 9.00 9.00 114 114 114 133 133 162 171 229 229 4.00 4.00 4.00 4.25 4.50 5.50 6.00 8.00 7.63 102 102 102 108 114 140 152 203 194 3.44 3.75 3.75 3.88 5.88 5.06 5.00 4.81 5.75 86 95 95 99 149 129 127 122 146 3.75 3.75 3.75 4.38 4.38 5.31 6.13 7.50 7.50 95 95 95 111 111 135 156 191 191 11.4 13.6 14.2 17.4 27.5 27.9 43.1 56.0 76.2 MICRON POWER DELIVERY 4 TERMINAL A D CATALOG GROUPS P/N A I IN MM B250-2263-GAF 4.75 121 B300-2264-GAF 5.25 133 B350-2265-GAF 5.38 137 B500-2266-GAF 5.63 168 B750-2267-GAF 7.44 189 B1K0-2268-GAH 7.75 199 B1K5-2269-GAH 7.75 199 B2K0-2270-GAH 7.63 194 B3K0-2271-GAH 8.75 222 B5K0-2272-GAH 10.44 265 J B250-2243-GAF B300-2244-GAF B350-2245-GAF B500-2246-GAF B750-2247-GAF B1K0-2248-GAH 24 4.75 5.00 5.13 5.75 7.00 8.13 121 127 130 146 178 207 B IN 4.50 4.50 5.25 5.25 6.38 6.75 6.75 9.00 9.00 9.00 MM 114 114 133 133 162 171 171 229 229 229 4.50 4.50 5.25 5.25 6.38 6.38 114 114 133 133 162 162 C B E DIMENSIONS INCHES (MM) C D IN MM IN MM 4.00 102 4.75 121 4.00 102 4.75 121 4.50 114 4.38 111 4.50 114 5.88 149 6.00 152 5.06 129 6.25 159 5.00 127 6.00 152 5.00 127 7.63 194 4.81 122 7.63 194 5.94 151 7.63 194 7.63 194 4.00 4.00 4.50 4.50 6.00 6.00 102 102 114 114 152 152 6 TERMINAL 3.75 4.75 3.88 4.88 5.06 5.06 95 121 99 124 129 129 E IN 3.75 3.75 4.38 4.38 5.31 6.13 6.13 7.50 7.50 7.50 MM 95 95 111 111 135 156 156 191 191 191 3.75 3.75 4.38 4.38 5.31 5.31 95 95 111 111 135 135 APPROX WEIGHT LBS 14.9 17.4 17.8 26.6 32.5 44.0 45.4 58.6 92.9 127.4 14.3 15.8 16.5 20.5 28.8 34.9 MICRON POWER DELIVERY CONNECTION DIAGRAMS - GLOBALTRAN 25 CONNECTION DIAGRAM: GROUP "A" CONNECTION DIAGRAM: GROUP "B" CONNECTION DIAGRAM: GROUP "D" CONNECTION DIAGRAM: GROUP "E" CONNECTION DIAGRAM: GROUP "G" CONNECTION DIAGRAM: GROUP "H" CONNECTION DIAGRAM: GROUP "I" Above 1 Kva CONNECTION DIAGRAM: GROUP "I" Through 1 Kva CONNECTION DIAGRAM: GROUP "C" CONNECTION DIAGRAM: GROUP "F" CONNECTION DIAGRAM: GROUP "J" MICRON POWER DELIVERY MEDIUM VOLTAGE CONTROL TRANSFORMERS Micron medium voltage control transformers have: * 130° C Insulation system. * 24" Mimimum primary lead length. * 60Hz. * HIPOT - 7,400 volts for 2400 primary. * HIPOT - 11,500 volts for 4160 and 2400 primaries. * 750 VA - Epoxy impregnated coils. * 1 KVA and larger - Epoxy potted primary coils. DIMENSIONS CONTROL TRANSFORMERS: MEDIUM VOLTAGE CATALOG OUTPUT NUMBER VA AMPS A VOLTAGE: IN MM *PRI: 4200 PRI: 2400 SEC: 120 H750-0030 * H750-0031 *PRI: 4160 PRI: 2400 SEC: 120/240 H1K0-0010 H1K0-0015 * HN1K5F1519P HN1K5G1519P * HN2K0F1519P HN2K0G1519P * HN3K0F1519P HN3K0G1519P * 26 B IN MM DIMENSIONS INCHES (MM) C D IN MM IN MM E IN APPROX. WEIGHT MM LBS 750 750 6.25 6.25 6.63 6.63 168 168 6.38 6.38 162 162 5.81 5.81 148 148 5.25 5.25 133 133 5.31 5.31 135 135 30.5 30.7 1000 1000 1500 1500 2000 2000 3000 3000 8.33/4.17 8.33/4.17 12.50/6.25 12.50/6.25 16.67/8.33 16.67/8.33 25.00/12.50 25.00/12.50 6.25 6.25 7.00 7.00 7.94 7.94 9.75 9.75 159 159 178 178 202 202 248 248 7.56 7.56 9.00 9.00 9.00 9.00 9.00 9.00 192 192 229 229 229 229 229 229 6.38 6.38 7.63 7.63 7.63 7.63 7.63 7.63 162 162 194 194 194 194 194 194 3.50 3.50 4.25 4.25 5.19 5.19 7.00 7.00 89 89 108 108 132 132 178 178 5.63 5.63 6.50 6.50 6.50 6.50 6.50 6.50 143 143 165 165 165 165 165 165 31.3 31.1 53.7 52.2 65.4 58.2 99.9 101.0 MICRON POWER DELIVERY DINergy ™ Industrial DIN Rail Power Supplies Micron DINergy™ Power Supply Selection Guide Output Output Voltage Output Input Power Voltage Adj. Current Peak Voltage Model (Watts) (VDC) Range (A) Current (A) (VAC) MDP30-24-1 30 24 22 - 28 1.25 1.70 90-255 MDP30-15-1 30 15 14 - 18 2.0 2.70 90-255 MDP30-12-1 30 12 10 - 14 2.5 3.40 90-255 MDP30-5-1 30 5 4.5 - 5.5 4.0 5.40 90-255 MDP50-24-1 50 24 22 - 28 2.27 - 1.79 3.09 90-255 MDP50-12-1 50 12 10 - 14 5.0 - 3.57 6.80 90-255 MD60-24-1 60 24 22 - 28 2.5 3.0 85-264 MD60-12-1 54 12 10 - 16 4.5 5.4 85-264 MD60-48-1 60 48 46 - 52 1.3 1.5 85-264 MD120-24-1 120 24 22 - 28 5.0 6.0 85-264 MD120-12-1 96 12 10 - 16 8.0 9.6 85-264 MD120-48-1 120 48 46 - 52 2.5 3.0 85-264 MD240-24-1 240 24 22 - 28 10.0 12.0 85-264 MD240-12-1 180 12 11 - 14 15.0 18.0 85-264 MD240-48-1 240 48 46 - 52 5.0 6.0 85-264 MD480-24-1 480 24 22 - 28 20.0 24.0 85-264 MD480-36-1 480 36 34 - 40 13.0 16.0 85-264 MD480-24-1 480 48 46 - 52 10.0 12.0 85-264 MD-PDMA 480 24 N/A 20.0 MAX 24.0 MAX 85-264 REDUNDANCY DIODE MODULE MD-VSB240-24-1 240 24 N/A 10.0 N/A 24VDC VOLTAGE SAG BUFFER +/-10% +/-5% MD-LAB-DINBRKTA N/A 24 N/A 3.4AH/20HR N/A N/A MD-LAB-DINBRKTB N/A 24 N/A 1.3AH/20HR N/A N/A MD-DINBRKTA BRACKET ASSEMBLY FOR 3.4AH SLA MD-DINBRKTB BRACKET ASSEMBLY FOR 1.3AH SLA 27 Size WxDxH(mm) 22.5X100X90 22.5X100X90 22.5X100X90 22.5X100X90 32X102X90 32X102X90 50x105x124 50x105x124 50x105x124 65x105x124 65x105x124 65x105x124 87x124x130 87x124x130 87x124x130 156x126x130 156x126x130 156x126x130 50x105x124 76X116X130 145X77X143 95X81X105 145X77X143 95X81X105 MICRON POWER DELIVERY PMA, PCMA, PMAS, PCMAS, PMN & PCMN encapsulated designs feature reduced stand-by power consumption and are available in various power ranges from 5 watts – 100 watts. The primary voltage range of 90 -264 Vac / 100 -353 Vdc with available single, dual or triple output voltages makes these the logical choice for PCB and chassis mount applications in otherwise hostile environments. The PCMASC power supply has been specifically designed to operate at -55ºC and is available at a power rating of 100 watts @ 24Vdc. PMmed / PCMmed encapsulated designs for medical applications are available in power ranges of from 15 watts – 100 watts. The primary voltage range of 90 -264 Vac / 100 -353 Vdc with single output selections for PCB and chassis mount applications where EN/UL 60 601-1/EN/UL 60 950-1 (2nd Edition) is necessary. Protected from vibration and the environment, the HMA, HMG, HMN, encapsulated DIN-Mount designs are available in power ranges of 15 and 30 watts with single, dual or triple output voltages. The HSA design is available through 120 watts with choices of multiple outputs through 48Vdc. The HSAC variant is certified to operate at -55ºC as well. The HSD product is a DC/DC DIN-Mount device in power ratings of 15 and 30 watts. 28 MICRON POWER DELIVERY …MTM Power DC/DC converters for vehicles and industrial applications… … For rugged vehicular or industrial applications, MTM Power DC/DC converters are available as a standard with single dual or triple outputs in various power ranges and if required as customized devices. Featuring isolation up to 4 kVac and available in metal or plastic case. PMG/PCMG encapsulated DC/DC designs are available in power ratings of 15 and 30 watts and with up to three output voltages. PMD/PCMD encapsulated DC/DC designs through 400 watts or the PCMDS (space saving) through 650 watts for vehicular applications. PMD encapsulated DC/DC designs for industrial applications with power ratings from 1 watt – 350 watts. MPK1, MPK2 plug-ins for 19” racks and other custom configurations utilize PMA, PMAS, PMN and PMG units and allow for up to six different, galvanically isolated outputs to 100 watts. PMA19 35 is a 19” narrow profile 35 watt unit available in 5, 12, 24 and 48 Vdc output voltage. 29 MICRON POWER DELIVERY DRY TYPE TRANSFORMERS GENERAL INFORMATION Micron can provide a general purpose or buck-boost transformer to satisfy your industrial or commercial application. Please refer to Catalog number LVGP-09A for further information 30 MICRON POWER DELIVERY NOTES: 31 MICRON POWER DELIVERY Micron Industries Corporation Oak Brook, IL 60523 Phone: 800-664-4660 FAX: 630-516-1820 www.micronpower.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : M.A, Kitun Create Date : 2011:06:16 11:52:13-05:00 Modify Date : 2011:09:09 15:19:12-05:00 Subject : control transformer catalog Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : M.A, Kitun Description : control transformer catalog Title : cct-04c Creator Tool : Microsoft® Excel® 2010 Metadata Date : 2011:09:09 15:19:12-05:00 Producer : Microsoft® Excel® 2010 Document ID : uuid:debc2403-7e96-46ad-8347-5e46528ad403 Instance ID : uuid:ee3f5d4c-15c8-469a-9283-f47997be9238 Page Count : 32EXIF Metadata provided by EXIF.tools