209 HDR 04RD FCC E970256 4( A)
2016-04-12
: Pdf 209 Hdr-04Rd-Fcc-E970256-4( Fcc-A) 209--HDR-04RD-FCC-E970256-4(_FCC-A) CertsReports 590068 ProductFiles
Open the PDF directly: View PDF .
Page Count: 24
Download | ![]() |
Open PDF In Browser | View PDF |
PEP Testing Laboratory REPORT NO. : E970256-4 FCC TEST REPORT According to FCC Part 15 Class A MODEL NO. Κ Κ APPLICANT Κ ADDRESS Κ EQUIPMENT HDR-04RD, HDR-04RJ, YSD-04RA, YDS-04RA-V, CV500-4CH, SN500-4CH HUNT ELECTRONIC CO., LTD. 9F., No. 171, Sec. 2, Datong Rd., Sijhih City, Taipei 22183, Taiwan, R. O. C. BY Κ DATE Κ CHECKED ISSUED H.264 4CH DVR NICK LEE SEP. 16, 2009 ΘThe test result refers exclusively to the test presented test model / sample. ΘWithout the written authorization of the test lab., the Test Report may not be copied. PEP TESTING LABORATORY NO. 9-6, Huzi, Hubei Village, Linkou Shiang, Taipei Hsien, Taiwan 244, R. O. C. TEL : 886-2-26021042 FAX : 886-2-26021045 Page 1 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 TABLE OF CONTENTS 1. General 3 1.1 General Information 1.2 Place of Measurement 2. Product Information 4 3. EUT Description And Test Methods/ Test Software Used/ Modification(s) 5 4. Supporting Devices To Test 7 5. Conducted Disturbance Test 8 5.1 Setup of the Test Facilities 9 6. Radiated Disturbance Test 6.1 Setup of the Test Facilities 6.2 Open Test Site Setup Diagram 6.3 Radiated Disturbance Emission Limit 7. Conducted Test Configuration Photo 11 8. Conducted Emissions Test Data 12 9. Radiated Test Configuration Photos 15 10. Radiated Emissions Test Data 16 11. List Of Test Equipment 17 12. Labelling Requirements 18 13. Information To The User 19 14. EUT Photographs 20 Page 2 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 1. General 1.1 General Information: Applicant : HUNT ELECTRONIC CO., LTD. Address : 9F., No. 171, Sec. 2, Datong Rd., Sijhih City, Taipei 22183, Taiwan, R. O. C. Manufacturer : HUNT ELECTRONIC CO., LTD. Address : 6F., No. 57Ε59, Jiun Hsien Rd., Chi Tu District, Keelung 20653, Taiwan, R. O. C. MEASUREMENT PROCEDURE: CISPR 22 1.2 Place of Measurement ϡ PEP TESTING LABORATORY ϡ NO. 9-6, Huzi, Hubei Village, Linkou Shiang, Taipei Hsien, Taiwan 244, R. O. C. E-Mail : peplab@ms32.hinet.net TEL : 886-2-26021042 Accreditation --FCC Registration No. : 97129 FAX : 886-2-26021045 (U. S. A.) Page 3 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 2. Product Information a. EUT Name: H.264 4CH DVR Κ c. CPU TypeΚ b. Model No. H D R- 04RD N/A Κ d. CPU Frequency N/A Κ e. Crystal/Oscillator(s) Κ f. Chassis Used 12MHz, 12.888MHz, 25MHz, 27MHz, 3 0MHz ABS Κ g. Port/Connector(s) Κ h. Power Rating i. Condition of the EUT : Video Input Port *4, Audio Input Port *1, Audio Output Port *1, Ethernet Port *1, USB Port *2, RS-232 Port *1, VGA Output Port *1, Monitor Output Port *1 AC Adapter--Manufacturer: Wearnes Model Number: WDS050120 Input: AC 100 -240V 50 -60Hz Output: DC 12V 4.16A ϭʳ Prototype Sample ϭʳ 9 Engineering Sample ϭ ʳProduction Sample j. Test Item Receipt Date : SEP. 01, 2008 k. Date(s) of performance of test: SEP. 01, 2008 – OCT. 16, 2008 Page 4 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 3. EUT Description And Test Methods/ Test Software Used/ Modification(s) Description about EUT The EUT is H.264 4CH DVR, which main function shall be digital recording supervisory system and monitoring at remote network system, and bearing model under test is HDR-04RD. The series model is HDR-04RJ, YSD-04RA, YDS-04RA-V, CV500-4CH, SN500-4CH. Those models have identical electrical design and construction except that they are different in model number for marketing purpose. EUT used adapter which is AC 100-240V, 50-60Hz. For the more details specification about EUT, please refer to the user’ s manual. About I/O Ports description as follow I/O Port Name Quantity Connect peripheral Name Video Input Port 4 DVD Player / Free-ended data Cable Monitor Output Port 1 TV / Free-ended data Cable Audio Input Port 1 DVD Player Audio Output Port 1 TV VGA Output Port 1 LCD Displayer Ethernet Port 1 PC USB Port 2 Mouse / HDD RS-232 Port 1 Free-ended data Cable Test Operation Mode and Step According to the major function designed, operation modes of conducted and radiated preliminary test are both Player mode. The detail as follow: To test EUT in the status of play video via DVD Player. After preliminary test, the worst-case test result was recorded and provided in the report. Test step 1. EUT should conform to I/O connect peripheral specification to link, and set up on the table according to regulation. 2. Turning on the EUT and peripheral power. Then execute EUT’ s main function and enable peripheral which is EUT connection. 3. Execute EMCTEST program and show H letter continuously to drive peripheral of PC. 4. Move EUT/ peripheral/ data cable to find the worst emission. 5. Starting to test. Page 5 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 Test Software(s) Used N/A Modifications 1. VGA out connector add gasket to connector traces ground. 2. USB1 connector and Ethernet port add gasket to connector traces ground. 3. Video port, RCA1 port’ s ground add spring to connector traces ground. 4. C68ΕC69 add 330pf cap. 5. F11 add 104pf cap. 6. J23 pin1Εpin4 add 104pf cap. 7. Video port’ s ground adds spring to connector traces ground. 8. Video portΕMonitor outΕAudio port’s signal line add 1000pf cap. 9. USB2 port 5V Vcc add 104pf cap. 10. CRG5D110 board’ s ground need connector traces ground. Page 6 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 4. Support Equipment Used TV (TV1) CPU : N/A FCC ID N/A Manufacturer SONY Model Number PVM-14N2E Power Supply Switching Power Cord Non-Shielded , Detachable,1.8m Data Cable 1 > Shielded , Detachable,1.2m 2 > Back Shell : N/A Κ Κ Κ Κ Κ Κ Κ Κ Κ Κ Κ DVD Player Manufacturer Pioneer Model Number DV-490V-S Power Supply AC110~127V, 220~240v 50-60Hz Power Cord Non-Shielded, Detachable, 1.8m Data Cable N/A LCD (LCD1 17”) FCC ID Declaration of Conformity(DoC) Manufacturer SAMSUNG Model Number 740B Power Supply Switch, 12Vdac Power Cord Non-Shielded, Detachable, 1.8m Data Cable 1 > Shielded , Detachable,1.7m 2 > Back Shell : Metal External Hard Disk (USB 2.0 HD) FCC ID N/A Manufacturer TeraSys Model Number F12-U Power Supply DC +12V/1.25A, Power Cord Non-Shielded , 1.5m (Core) Data Cable 1 > Shielded, detachable, 1.7m 2 > Back Shell: N/A Κ Κ Κ Κ Κ Κ Κ Κ Κ Κ Κ Κ Page 7 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 5. Conducted Disturbance Test 5.1 Conducted Disturbance Emission Limit Frequency Maximum RF Line Class Voltage dB(µV) A MHz QUASI- PEAK 0.15 – 0.5 79 0.5 – 30.0 73 Remarks: In the above table, the tighter limit applies at the band edges. Page 8 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 6. Radiated Disturbance Test 6.1 Setup of the Test Facilities The equipment under test was setup on the non-conductive table in the open field site. The table was placed on a remote turntable constructed of a wooden material. The top of the table is located 1m above the ground plane. The turntable was rotated to obtain the maximum level of radiated emissions from the system containing the EUT for each emissions level investigated. 6.2 Open Test Site Setup Diagram 10m 4m (EUT) 1m GROUND PLANE TURN TABLE 0.8m TO RECEIVER Page 9 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 6.3 Radiated Disturbance Emission Limit Limits for radiated disturbance of Class A ITE at a measuring distance of 10 m Frequency MHz Field Strength dB(µV/m) 30 – 88 39.0 88 – 216 43.5 216 – 960 46.4 960 above 49.5 NOTES 1 The lower limit shall apply at the transition frequency. 2 Additional provisions may be required for cases where interference occurs. Page 10 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 7. Conducted Test Configuration Photo * FRONT VIEW * Page 11 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 8. Conducted Emissions Test Data Model No. : HDR-04RD : 150kHz to 30MHz Detector : Peak Value Temperature : 29 Humidity : 48 % Frequency Test Data : range # # к < LINE > < NEUTRAL > 240 241 Note 1. Level = Read Level + Cable Loss + Probe (LISN) 2. Over Limit = Level – Limit = Margin Page 12 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 Page 13 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 Page 14 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 9. Radiated Test Configuration Photos * FRONT VIEW * * REAR VIEW * Page 15 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 10. Radiated Emissions Test Data Model No. : HDR-04RD Frequency range : 30MHz to 1GHz Detector : Quasi-Peak Value Frequency range : above 1GHz Detector : Quasi-Peak/Average Value Temperature : 26 Humidity : 42 % к Antenna polarization : HORIZONTAL ; Test distance : 10m ; Over Limit Read Antenna Cable Preamp Limit Line Level Factor Loss Factor (dB) (dB) (dB) Freq. Level (MHz) (dBuV/m) (dB) (dBuV/m) (dBuV) Azimuth Antenna (̓angle) High(m) !!!!74/711!!!39/63!!!.21/59!!!4:/11!!!46/53!!!22/14!!!3/88!!!31/81!!!351!!!!5/1!!!!! !!!238/251!!!42/:1!!!.22/71!!!54/61!!!48/74!!!22/63!!!4/48!!!31/73!!!!97!!!!5/1!!!!! !!!361/121!!!49/55!!!.!8/:7!!!57/51!!!54/:5!!!21/66!!!5/16!!!31/21!!!245!!!!5/1!!!!! !!!461/121!!!49/12!!!.!9/4:!!!57/51!!!4:/92!!!24/7:!!!5/62!!!31/11!!!463!!!!5/1!!!!! !!!611/121!!!42/16!!!.26/46!!!57/51!!!39/86!!!27/86!!!6/47!!!2:/92!!!371!!!!5/1!!!!! !!!922/161!!!35/77!!!.32/85!!!57/51!!!26/:5!!!32/74!!!7/52!!!2:/43!!!411!!!!5/1!!!!! Antenna polarization : VERTICAL ; Test distance : 10m ; Over Limit Read Antenna Cable Preamp Limit Line Level Factor Loss Factor (dB) (dB) (dB) Freq. Level (MHz) (dBuV/m) (dB) (dBuV/m) (dBuV) Azimuth Antenna (̓angle) High(m) ! !!!238/2:1!!!38/2:!!!.27/42!!!54/61!!!43/:3!!!22/63!!!4/48!!!31/73!!!247!!!!2/1!!!!! !!!313/621!!!46/15!!!.!9/57!!!54/61!!!51/:2!!!21/79!!!4/86!!!31/41!!!!73!!!!2/1!!!!! !!!361/111!!!49/74!!!.!8/88!!!57/51!!!55/24!!!21/66!!!5/16!!!31/21!!!291!!!!2/1!!!!! !!!489/121!!!47/62!!!.!:/9:!!!57/51!!!48/58!!!25/62!!!5/75!!!31/22!!!!5:!!!!2/1!!!!! !!!732/121!!!39/31!!!.29/31!!!57/51!!!34/17!!!2:/38!!!6/82!!!2:/95!!!384!!!!2/1!!!!! !!!922/591!!!35/74!!!.32/88!!!57/51!!!26/:2!!!32/74!!!7/52!!!2:/43!!!3:5!!!!2/1!!!!! ! Note: 1. 2. Level = Read Level + Antenna Factor + Cable Loss – Preamp Factor Over Limit = Level – Limit Line Page 16 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 11. List of Test Equipment ! Test Site Conduction (No.1) OP (No.1) Instrument Manufacturer Model No. S/N Next Cal. Date Cal. Interval Receiver R&S ESHS10 830223/008 Nov. 23, 2009 1 Year Spectrum Analyzer R&S FSP 833387/001 Nov. 16, 2009 1 Year RF cable N/A N/A L.I.S.N R&S ESH2-Z5 DC LISN Mess Tec LN-KFZ/100 Receiver R&S ESVS30 Antenna Schwarzbeck RF cable N/A Pre - Amp Schaffner VULB 9161 N/A Jan. 18, 2010 1 Year 831886/004 Apr. 22, 2010 1 Year 2001/019 Apr. 22, 2010 1 Year 863342/012 Jul. 29, 2010 1 Year 4051 Jan. 22, 2010 1 Year N/A N/A Jan. 18, 2010 1 Year CPA- 9232 1012 Jan. 20, 2010 1 Year SE Page 17 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 12. Labeling Requirement A warning label with the following statement shall be permanently attached and conspicuously located on the equipment: This device complies with Part 15 of the FCC Rules . Operation is subject to the following two conditions : (1) This device may not cause harmful interference , and (2) this devices must accept any interference received , including interference that may cause undesired operation. Page 18 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 13. Information to The User The following FCC statement should be declared in a conspicuous location in the user’ s manual. Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Page 19 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 14. EUT Photographs MODEL NO. : HDR-04RD EUT FRONT VIEW EUT REAR VIEW Page 20 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 EUT INSIDE VIEW EUT COMPONENT VIEW Page 21 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 EUT SOLDERING VIEW EUT COMPONENT VIEW Page 22 of 23 PEP Testing Laboratory REPORT NO. : E970256-4 EUT SOLDERING VIEW Page 23 of 23 VERIFICATION WE HEREBY VERIFY THAT: The Equipment Under Test (EUT) listed below has completed RFI testing by PEP Testing Laboratory and the interference emissions can pass FCC Class A limitations. The test report shall not be reproduced except in full, without the written approval of the laboratory. The estimate uncertainty of the test result is about ±3dB. The test result is only effect for the sample as below. APPLICANT : HUNT ELECTRONIC CO., LTD. EQUIPMENT : H.264 4CH DVR MODEL NO. : HDR-04RD, HDR-04RJ, YSD-04RA, : YDS-04RA-V, CV500-4CH, SN500-4CH REPORT NO. : M. Y. TSUI / Manager E970256-4 Date : SEP. 16, 2009
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Create Date : 2009:09:17 06:22:48Z Modify Date : 2009:09:17 14:25:05+08:00 Page Count : 24 Creation Date : 2009:09:17 06:22:48Z Mod Date : 2009:09:17 14:25:05+08:00 Producer : Acrobat Distiller 5.0.5 (Windows) Metadata Date : 2009:09:17 14:25:05+08:00EXIF Metadata provided by EXIF.tools