Rittal RiLine60

239980-Attachment 239980-Attachment 239980-Attachment 639889 Batch8 unilog cesco-content

432027-Catalog 432027-Catalog 432027-Catalog 639889 Batch6 unilog cesco-content

250335-Catalog 1 250335-Catalog_1 250335-Catalog_1 639889 Batch7 unilog cesco-content

351225-Attachment 351225-Attachment 351225-Attachment 639889 Batch5 unilog cesco-content

2014-07-05

: Pdf 249613-Attachment 249613-Attachment 639889 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 12

DownloadRittal - RiLine60
Open PDF In BrowserView PDF
Rittal – RiLine60

60 mm system technology
for the global market

Rittal RiLine60 – three systems

Classic

Innovative and compact

for busbars with a square crosssection up to 30 x 10 mm in feedercircuits up to 700 A

PLS 800
For feeder-circuits up to 700 A

2

PLS 1600
For feeder-circuits up to 1400 A

Unlike busbar sections with a square cross-section, PLS sections offer
unrestricted top-mounting of the busbar supports with top-mounting
components.

Rittal RiLine60 cULus listed

Simple, fast system sign-offs
Save time and money with easier

Industrial
controllers
to UL 508A

UL and CSA sign-offs.
The approval of power distribution
components is becoming ever
more important for international

Approval status RiLine60

switchgear producers.
approval of RiLine60
busbar systems offers significant
advantages for both the UL and

Sign-off by inspector

CSA market. Complex, timeconsuming engineering, inspection
and sign-off processes are reduced

Review of the COA(s)
of all UL-recognized
components used

to a minimum.

Inspection of UL-compliant assembly

On-site sign-off by the
Authority Having Jurisdiction (AHJ)

Important benefits and added value with RiLine60
1. Dramatic time savings
Straightforward UL and CSA sign-off
processes
2. Conditions of Acceptability (COA)
are eliminated, documentation work
is minimised
No additional tests required as with
UL-recognized components.

Rittal RiLine60 cULus listed

3. Cost savings for listed
switchgear producers
The usual UL costs for file entry of the
UL-recognized components are eliminated.

5. Barrierless access to the
CSA market
products are accepted on
the Canadian market with no further
test requirements.

4. A high level of acceptance among
end customers
RiLine60
meets the requirements of valid safety standards to perfection.

6. Time- and cost-efficient project
planning
Reduced project planning work
when incorporating the engineering
considerations.

3

Rittal RiLine60 – Details for
mechanical and plant engineering
Background information on UL
UL or Underwriter Laboratory was founded
in 1894 as a non-profit-making organisation for testing and certification. UL operates five testing laboratories in the United
States and subsidiaries worldwide, with an
emphasis on product testing aimed at general safety.
Why are UL approvals important?
● International regulations and standards
such as NEMA and IEC are used as
a basis by manufacturers for product
developments and subsequent testing.
● Nationally recognised test laboratories
confirm and certify that a product
complies with the specific standards;
in North America this is carried out
by organisations such as UL or CSA
(Canadian Standards Association).
● For many applications, the sole use of
UL and/or CSA-approved products is a
requirement; consequently, it is advisable to design electrical controllers for
North American applications with suitable UL-approved components.
How does the US system for electrical
safety work?
Every piece of electrical equipment
(machine/plant) is tested by the competent local inspector (AHJ = Authority
Having Jurisdiction) prior to commissioning. The AHJ has the final say with regard
to commissioning. All AHJs use Standard
NFPA 70 (NFPA = National Fire Protection
Association) as a basis, which is generally
regarded as the NEC (National Electrical
Code). NFPA 70 is therefore an important
basis for UL 508A (Industrial Control
Panels).

The AHJ considers the use of UL-recognized or UL-listed components an important indication that a system complies with
the safety requirements to NFPA 70. This
saves time and money during construction
and commissioning of the equipment, as
the UL symbol indicates that testing of the
components and/or of the system did not
reveal any foreseeable risks with regard
to fire, electric shock and associated dangers.
The UL symbols: “UL-listed” or
“UL-recognized”
When labelling UL-approved products,
a general distinction is made between
Recognized Components and Listed
Devices:
1

2

(Recognized Components)
This label is used on products which
are not complete in terms of their application. These products are listed in the
UL’s “yellow component database”.
The correct use of such components
must make due allowance for the
“Conditions of Acceptability”, listing the
framework conditions and application
parameters approved by the UL.
(Listed Devices)
Here, it is only important to note that
the remarks and rating data specified
on the product are observed with the
application. Terminals for field-wiring
are authorised as Listed Devices
(cf. point 3).

1

Recognized Component
Sample rating plate for a busbar
support with
.

4

Application areas for UL 508 and
UL 508A
UL 508 describes industrial control components and is therefore the decisive standard for the assessment of Rittal SV components. For example, this standard contains
information on:
● Starters
● Relays and contactors
● Circuit-breakers
● Controllers
UL 508A describes industrial control panels and is therefore the decisive standard
for switchgear manufacturers.
For example, this standard contains information on:
● Machine controllers
● Elevator controllers
● Crane controllers
● Equipment for heating, air-conditioning
and ventilation systems
Both standards describe control systems
for general industrial applications with a
rated voltage of up to 600 V. The maximum
permissible ambient temperature is 40°C.
Distinguishing between feeder- and
branch-circuits
Standard UL 508A makes a distinction
between feeder-circuits and branch &
control circuits. Generally speaking, the
term “feeder-circuits” refers to the part of
the circuit located at the supply end before
the last over-current protective device (a
device approved to UL 489). Increased
requirements with regard to creepage distances and clearances apply to this part
of the circuit.

2

Listed Device
Sample rating plate for a busbar
support with
.

Rittal RiLine60 cULus listed

Compliance with standards is inThe term “branch & control circuits” refers
to the part of the circuit located after the
last over-current protective device. When
using busbar systems, it is important to
know whether the application is in the
feeder section or the branch section, as
the requirements governing the required
creepage distances and clearances are
significantly higher for feeder-circuits.

Important remarks
for the use of busbar systems
to UL 508A
1. Creepage distances and clearances
One of the principal requirements in
UL 508A is the amendment to the required
creepage distances and clearances for
feeder-circuits.
For applications >250 V the following distances and clearances are required:
● Between phases:
A Creepage distance 50.8 mm (2 inches)
B Clearance 25.4 mm (1 inch)
● Between phase and earthed,
uninsulated metal parts:
C Creepage distance 25.4 mm (1 inch)
D Clearance 25.4 mm (1 inch)
Rittal RiLine60 complies with these requirements. All busbar connection adaptors and
component adaptors (OM adaptors with
standard AWG connection cables and
circuit-breaker adaptors) have been designed in accordance with these requirements. However, users should bear in mind
a small number of differences from the IEC
version:

● In order to guarantee the required distances between live parts and the
earthed mounting plate, the use of a
Rittal RiLine60 base tray is compulsory.
2. Rated currents
For untested busbar applications, UL 508A
specifies a current carrying capacity of
1000 A/inch2 (1.5 A/mm2) in the absence of
testing.
This value may be higher if the product or
application has undergone suitable testing. Rittal has conducted extensive testing
in this respect in order to give users the
maximum benefits when using the RiLine60
busbar system. The benefit of such testing
is that SV busbar systems with higher rated
currents may be used than permitted by
the default value. For example, a busbar
with dimensions 30 x 10 mm can take 700 A
instead of 465 A.
3. Terminals for factory or field-wiring
In accordance with the UL standards,
connection terminals may be approved
for factory or field-wiring. If a terminal is
approved for factory-wiring, it may only be
used in switchgear assembly by suitably
trained professionals.

dispensable for the safe design
and operation of electrical systems.
This is particularly true of the North
American market.
Here, products which conform to
the relevant regulations are a key
factor for problem-free acceptance
of electrical systems.
UL-approved components provide
a suitable basis, saving time and
money for the user by minimising
acceptance problems in advance.

If connection terminals are to be used in
the field (e.g. on a construction site), the
component must be approved for field-wiring. The terminals of the busbar connection adaptors and component adaptors
in the Rittal RiLine60 series have therefore been tested for field-wiring applications.

● Special UL busbar supports for flat bars
and Rittal PLS with increased creepage
distances and clearances.

D
C

A

B

Definition of creepage distances and clearances:
A

Creepage distance between active conductors/busbars

B

Clearance between active conductors/busbars

C

Creepage distance between active conductors/busbars and earthed metal parts

D

Clearance between active conductors/busbars and earthed metal parts

Rittal RiLine60 cULus listed

5

Product overview
RiLine60 busbar system for flat copper bars (3-/4-pole)
For feeder-circuits UL 508A,

, file E191125

Designation

Version

Bar centre
distance
mm

For
busbars
mm

Packs
of

Model No.
SV

Cat. 32,
page

Busbar support

3-pole

60

15 x 5 – 30 x 10

4

9340.050

354

Busbar support

4-pole

60

15 x 5 – 30 x 10

4

9340.004

380

Busbar support 30 x 10 PLUS

4-pole

60

30 x 10

4

9342.014

382

System components
Model No. SV

Length
mm

Packs
of

3-pole

4-pole

Cat. 32,
page

500

2

9340.100

–

351

700

2

9340.110

–

351

900

2

9340.120

–

351

1100

2

9340.130

–

351

Base tray for SV 9340.004

1100

2

–

9340.134

381

Base tray for SV 9342.014

1100

2

–

9342.134

383

700

2

9340.200

–

351
351,
381/383

Designation

Base tray for SV 9340.050

Cover section
Base tray infill

1100

2

9340.210

9340.214

100

2

9340.140

–

351

Support panel for cover section

5

9340.220

9340.224

351,
381/383

End covers for SV 9340.050

2

9340.070

–

354

End covers for SV 9340.004

2

–

9340.074

380

End covers for SV 9342.014

2

–

9342.074

382

Note:
The use of a base tray is compulsory for UL applications.

RiLine60 busbar system PLS 800 (3-pole)
For feeder-circuits UL 508A,

, file E191125

Designation

Version

Bar centre
distance
mm

For
PLS busbars1)
Cross-section mm2

Packs
of

Model No.
SV

Cat. 32,
page

Busbar support
PLS 800

3-pole

60

300

4

9341.050

355

Length
mm

Packs
of

Model No.
SV

Cat. 32,
page

500

2

9341.100

353

700

2

9341.110

353

900

2

9341.120

353

1100

2

9341.130

353

700

2

9340.200

353

1100

2

9340.210

353

100

2

9341.140

353

Support panel for cover section

5

9340.220

353

End covers for SV 9341.050

2

9341.070

355

System components
Designation

Base tray

Cover section
Base tray infill

1) 5

mm bar thickness

Note:
The use of a base tray is compulsory for UL applications.

6

Rittal RiLine60 cULus listed

Product overview
RiLine60 busbar system PLS 1600 (3-/4-pole)
For feeder-circuits UL 508A,

, file E191125

Designation

Version

Bar centre
distance
mm

For
PLS busbars1)
Cross-section mm2

Packs
of

Model No.
SV

Cat. 32,
page

Busbar support
PLS 1600

3-pole

60

900

4

9342.050

355

Busbar support
PLS 1600 PLUS

4-pole

60

900

4

9342.004

382

System components
Designation

Packs
of

3-pole

4-pole

Cat. 32,
page

500

2

9342.100

–

353

700

2

9342.110

–

353

900

2

9342.120

–

353

1100

2

9342.130

9342.134

353/383

Base tray

Cover section

700

2

9340.200

–

353

1100

2

9340.210

9340.214

353/383

100

2

9342.140

–

353

–

5

9340.220

9340.224

353/383

2

9342.070

9342.074

355/382

Base tray infill
Support panel for cover section
End covers for busbar supports
1) 10

Model No. SV

Length
mm

mm bar thickness

Note:
The use of a base tray is compulsory for UL applications.

Busbar connection adaptor (3-/4-pole)
For feeder-circuits UL 508A,
Rated
current
up to

, file E191125
Model No. SV
Clamping
area for
Packs
laminated
Outlet at
Outlet at
Outlet at
of
copper bars
top/bottom
top
bottom
mm

Rated
operating
voltage

Connection
of round conductors
mm2 (AWG)

600 V~

6 – 16
(AWG 10 – AWG 6)

–

1

–

9342.200

9342.210

356

125 A

600 V~

16 – 35
(AWG 6 – AWG 2)

10 x 7.8

1

–

9342.230

9342.240

356

250 A

600 V~

35 – 120
(AWG 2 – MCM 250)

18.5 x 15.5

1

9342.250

9342.260

9342.270

356

600 V~

95 – 300
(AWG 3/0 – MCM 600)

33 x 20

1

–

9342.290

9342.300

356

125 A

600 V~

16 – 35
(AWG 6 – AWG 2)

10 x 7.8

1

9342.224

9342.234

9342.244

384

250 A

600 V~

35 – 120
(AWG 2 – MCM 250)

18.5 x 15.5

1

9342.254

9342.264

9342.274

384

Cat. 32,
page

3-pole
60 A

600 A
4-pole

Rated
current
up to

Rated
operating
voltage

Connection
of round conductors
mm2 (AWG)

800 A

600 V~

1400 A

600 V~

Clamping area for
laminated copper bars
mm

Model No. SV
Outlet at top/bottom
Packs
of

Expansion
Busbar
set
connection
for 4-pole
adaptor
(3 x 1-pole) configuration

Cat. 32,
page

for
5 mm
bar
thickness

for
10 mm
bar
thickness

95 – 300
(AWG 3/0 – MCM 600)

33 x 27

33 x 22

1 set

9342.310

9342.3141) 357/385

–

65 x 27

65 x 22

1 set

9342.320

9342.3241) 357/385

3-/4-pole

1) Packs

Rittal RiLine60 cULus listed

of = 1

7

Product overview
OM adaptor/OM support (3-pole)
For feeder-circuits UL 508A,

Version

ConstrucRated current
tion
up to
width
mm

, file E191125
Rated
operating
voltage

Support rails
Connection
Connection of round
Packs Model No. Cat. 32,
cables1) conductors Height Qty.
of
SV
page
mm
mm2

45

25 A

600 V~

AWG 12

–

10

1

1

9340.3102)

364

45

25 A

600 V~

AWG 12

–

10

1

1

9340.340

364

45

25 A

600 V~

AWG 12

–

10

1

1

9340.3703)

364

45

32 A

600 V~

AWG 10

–

10

1

1

9340.350

364

45

32 A

600 V~

AWG 10

–

10

2

1

9340.380

364

55

32 A

600 V~

AWG 10

–

10

1

1

9340.460

364

55

32 A

600 V~

AWG 10

–

10

2

1

9340.470

364

75

40 A

600 V~

AWG 8

–

7.5

2

1

9340.7104)

365

55

65 A

600 V~

AWG 6

–

10

1

1

9340.4102)

365

55

65 A

600 V~

AWG 6

–

10

1

1

9340.430

365

55

65 A

600 V~

AWG 6

–

10

2

1

9340.450

365

75

65 A

600 V~

AWG 6

–

7.5

1

1

9340.7004)

365

45

25 A

600 V~

–

1.5 – 4

10

1

1

9340.9005)

362

45

25 A

600 V~

–

1.5 – 4

10

2

1

9340.9106)

362

55

25 A

600 V~

–

1.5 – 4

10

2

1

9340.9306)

362

45

–

–

–

–

10

–

1

9340.2603)

368

55

–

–

–

–

10

1

1

9340.270

368

Connection pin

20

9340.280

401

Insert strip 10 mm

2

9340.290

400

OM
adaptor

OM
Premium
adaptor
OM
support

Accessories

1) AWG

= American Wire Gauges
AWG 12 = 3.31 mm2 4 mm2
AWG 10 = 5.26 mm2 6 mm2
AWG 8 = 8.37 mm2 10 mm2
AWG 6 = 13.3 mm2 16 mm2
2) Without support frame
3) With pin block
4) Witihout support frame, with insert strips
5) With sub-unit and pin block
6) With connector outlet

Circuit-breaker component adaptor (3-pole)
For feeder-circuits UL 508A,

, file E191125
Clamping area
Model No. SV
for laminated Packs
Cat. 32,
Cable outlet page
copper bars
of Cable outlet
1)
1)
top
bottom
mm

Construction
width
mm

Rated
current
up to

Rated
operating
voltage

Connection
of round conductors
mm2 (AWG)

72

100 A

600 V~

10 – 35
(AWG 6 – AWG 2)

10 x 7.8

1

9342.400

9342.410

370

90

125 A

600 V~

35 – 120
(AWG 2 – MCM 250)

18.5 x 15.5

1

9342.540

9342.550

370

600 V~

35 – 120
(AWG 2 – MCM 250)

18.5 x 15.5

1

9342.600

9342.610

371

1

9342.700

9342.710

371

105
140

250 A
600 A

600 V~

–

32 x

102)

Accessories
Insert strip 25 mm, for SV 9342.700/.710

43)

9342.720

400

1) Switch

outlet or outgoing cable
2) Via M10 screw terminal
3)
1 set

8

Rittal RiLine60 cULus listed

Product overview
Circuit-breaker component adaptor (4-pole)
For feeder-circuits UL 508A,

Rated
Connection
operating of round conductors
voltage
mm2 (AWG)

Model No. SV
Clamping area
Cat. 32,
for laminated Packs
Cable
outlet Cable outlet page
of
copper bars
1)
1)
top
bottom
mm

Construction
width
mm

Rated
current
up to

120

125 A

600 V~

35 – 120
(AWG 2 – MCM 250)

18.5 x 15.5

1

9342.504

9342.514

386

140

250 A

600 V~

35 – 120
(AWG 2 – MCM 250)

18.5 x 15.5

1

9342.604

9342.614

386

1) Switch

Rittal RiLine60 cULus listed

, file E191125

outlet or outgoing cable

9

Short-circuit resistance diagrams
Rittal RiLine60 UL 508
The short-circuit resistance of Rittal
RiLine60 has been extensively tested.
Short-circuit resistance to UL criteria is
assessed via the root-mean-square value
of the short-circuit current (IRMS), which
must be applied for at least 3 periods.

During the course of testing, the test equipment has been adjusted to the respective
root-mean-square values (IRMS). The resultant peak short-circuit currents Ip are shown
in the short-circuit protection diagrams
below.

Busbar supports

Settings IRMS (Ieff.) of the test equipment without prefuse:

60 mm bar centre distance,
for busbars 15 x 5 – 30 x 10 mm.
Note:
SV 9340.050 with 30 x 5/10 mm
With a pre-fuse, the following short-circuit
value can be achieved:
Support spacing: 350 mm
Fuse: Class L 800 A
IRMS: 50 kA

Support spacing
mm

IRMS
kA

Support spacing
mm

IRMS
kA

250

35

250

30

500

25

500

22

Ip peak short-circuit current [kA]

Model No. SV 9340.050
with 30 x 5/10 mm

Model No. SV 9340.050
with 25 x 5 mm
20 x 5/10 mm
15 x 5/15 mm

80

80

75

75

70

70

65

65

Ip peak short-circuit current [kA]

for feeder-circuits 700 A,
3-pole

60
55
50
45
40
35

60
55
50
45
40
35

30

30

25

25

20

20
200 250 300 350 400 450 500 550 600

200 250 300 350 400 450 500 550 600
Busbar support spacing [mm]

for feeder-circuits
700 A (PLS 800)/1400 A (PLS 1600),
3-pole

Settings IRMS (Ieff.) of the test equipment without prefuse:
Support spacing
mm

IRMS
kA

Support spacing
mm

IRMS
kA

200

22

150

35

500

14

500

25

60 mm bar centre distance,
for Mini-PLS special busbars.
Note:
SV 9342.050 (PLS 1600)
With a pre-fuse, the following short-circuit
value can be achieved:
Support spacing: 250 mm
Fuse: Class L 1400 A
IRMS: 65 kA
Ip peak short-circuit current [kA]

Model No. SV 9341.050 (PLS 800)
80

80

75

75

70

70

65

65

60
55
50
45
40
35

60
55
50
45
40
35

30

30

25

25

20

20
150 200 250 300 350 400 450 500 550
Busbar support spacing [mm]

10

Model No. SV 9342.050 (PLS 1600)

Ip peak short-circuit current [kA]

PLS busbar supports

Busbar support spacing [mm]

150 200 250 300 350 400 450 500 550
Busbar support spacing [mm]

Rittal RiLine60 cULus listed

Short-circuit resistance diagrams
Busbar supports

115

up to 700 A, 4-pole

110

Model No. SV 9340.004/SV 9342.014

105

60 mm bar centre distance

100

Settings IRMS (Ieff.) of the test equipment without prefuse:
Model No.
SV

Busbar
mm

a 9340.004

15 x 5 –
30 x 10

b 9342.014

30 x 10

95
90

Support
spacing
mm

IRMS

250

30

500

22

250

35

500

25

Ip peak short-circuit current [kA]

85
80
75
70
65
60

b
a

55
50
45
40
35
30
25
20
200 250 300 350 400 450 500
Busbar support spacing [mm]

80

up to 1400 A, 4-pole

75

Model No. SV 9342.004

70

60 mm bar centre distance,
for PLS special busbar 1400 A.

65

Ip peak short-circuit current [kA]

PLS busbar support

Settings IRMS (Ieff.) of the test equipment without prefuse:
Busbar
mm

60

PLS 1600

55

Support
spacing
mm

RMS
kA

150

35

500

25

50
45
40
35
30
25
20
150 200 250 300 350 400 450 500 550
Busbar support spacing [mm]

Rittal RiLine60 cULus listed

11

All in all – solutions from Rittal

Industrial Enclosures

Power Distribution

Busbar systems RiLine60
Busbar systems 40/100/150/185 mm
Ri4Power low-voltage distribution systems

Electronic Packaging

System Climate Control

IT Solutions

Rittal has one of the largest ranges of enclosures available
for immediate delivery. However, Rittal also supplies integrated solutions – up to Level 4. This comprises mechanical
installation, power supply, electronic components, climate
control and central monitoring. For all of your requirements.

Fully assembled and functional. Wherever in the world you
develop and implement solutions for yourself and your
customers, we are close at hand. The global alliance
between production, distribution and service guarantees
closeness to the customer. Worldwide!

Rittal GmbH & Co. KG  Postfach 1662  D-35726 Herborn
Telephone: +49(0)2772 505-0  Telefax: +49(0)2772 505-2319  eMail: info@rittal.de  www.rittal.com

Switch to perfection

02/09  E480

Communication Systems

R



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Page Mode                       : UseNone
XMP Toolkit                     : 3.1-701
Creator Tool                    : FrameMaker 8.0
Create Date                     : 2009:01:16 09:58:20Z
Modify Date                     : 2009:01:26 09:17:31+01:00
Metadata Date                   : 2009:01:26 09:17:31+01:00
Format                          : application/pdf
Title                           : Rittal - RiLine60
Creator                         : Rittal GmbH & Co.KG
Description                     : RiLine 60
Subject                         : 60 mm system technology for the global market
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Keywords                        : 60 mm system technology for the global market
Document ID                     : uuid:9c7d59b1-e4a5-4a2f-a22b-0ed1cea18085
Instance ID                     : uuid:03f668aa-8f59-4e3e-9d0a-21597e72eb7b
Page Count                      : 12
Author                          : Rittal GmbH & Co.KG
EXIF Metadata provided by EXIF.tools

Navigation menu