HOW TO INSTALL SYSTEM
To choose the right length of pipe freeze protection cable,
cable should be long enough to run along bottom of	
horizontal pipes and weather side of vertical pipes (in­cluding valves) without crossing or spiraling. Never use	
a cable longer than the pipe it is intended to protect.

1.	 Refer to the chart inside or on the package for	
proper cable selection.
2.	 Cable will be applied straight along pipe, and will	
protect pipes up to 1½ inches in diameter.*

AHB Series
Electric Water Pipe

www.easyheat.com
USA		

Canada

2 Connecticut South Drive	
East Granby CT 06026	
Tel	 800/537-4732	
Fax	 800/541-7451	

99 Union Street
Elmira ON N3B 3L7
Tel	 519/669-2444
Fax	 519/669-6419

PRODUCT SELECTION GUIDE
	
EasyHeat
		
	
ITEM #

3.	 For pipe lengths other than standard heating cable sizes,
and over 1/4 inch in diameter, use two heating cables in
parallel on opposite sides of the pipe (see illustration). Maximum “overrun” should not exceed 3 feet. Do not install on
pipe shorter than 3 feet long.**

	
	
	
	
	
	
	
	
	
	
	

4.	 Wrap the entire pipe and cable with insulation. Com­
plete the installation with the weatherproof wrap and the
caution signs. For plastic pipe, we recommend wrapping
pipe in aluminum foil before installing cable for better heat
distribution.

	
	

DESCRIPTION

AHB HEATING CABLE / ACCESSORIES
AHB-013	
	3´ LENGTH, 21 WATTS
AHB-016	
	6´ LENGTH, 42 WATTS
AHB-019	
	9´ LENGTH, 63 WATTS
AHB-112	
	12´ LENGTH, 84 WATTS
AHB-115	
	15´ LENGTH, 105 WATTS
AHB-118	
	18´ LENGTH, 126 WATTS
AHB-124	
	24´ LENGTH, 168 WATTS
AHB-130	
	30´ LENGTH, 210 WATTS
AHB-140	
	40´ LENGTH, 280 WATTS
AHB-160	
	60´ LENGTH, 420 WATTS
AHB-180	
	80´ LENGTH, 560 WATTS
HCA	
HCP1	

Easy Heat products are provided with a LIMITED WARRANTY:
See Installation & Operation Instructions or contact 	
EasyHeat for complete terms and conditions.

•	For Metal
and Plastic
Water Pipes
•	With	
Energy-saving
Thermostat

**	For details please	
contact your EasyHeat	
representative.

C

!

Stop Pipe
and Valve
Freeze-up

APPLICATION TAPE
CABLE SENTRY

*	For pipe diameters	
greater than 1½ inches,
please contact your	
EasyHeat representative.

WARNING: EasyHeat recommends using a ground
fault protected receptacle.

Freeze
Protection
Cable

Listed
© 2010 EasyHeat		

40200-001 Rev. 5

Stop Pipe Freeze-up
Electric Water Pipe Freeze Protection Cable

•	Keeps water flowing down to —40°F (—40°C)
•	Pre-assembled, ready to install

EasyHeat, the leader in residential pipe freeze protec-	
tion, presents the AHB Series pipe heating system. Preassembled and ready-to-install, the cable prevents pipes from
freezing, keeping water flowing to —40°. Using an energysaving thermostat, AHB cables operate on 120 Volts AC and
are suitable for use on water-filled plastic and metal pipes.

The AHB Series system is easy to buy and to install, engi­neered
in 3-foot increments (up to 18 feet) to accommodate many pipe
lengths with diameters up to 1½ inches. Simply run the cable
straight along the pipe and valves according to the included
instructions, affix with our premium application tape and insulation, then plug into a ground fault protected electrical outlet.

•	With power indicator light
•	With energy-saving thermostat
INDICATOR LIGHT
The AHB system includes
a power indi­cator light
in the plug for assurance that the system has
power.

When it comes to pipe freeze protection, stay with the leader–
EasyHeat.

This system can be installed with the confidence that it will
operate for years without requiring service. All components
are made of the highest quality materials and are tested	
during critical points in the manufacturing process.

SIMPLE TO INSTALL

HOW MUCH CABLE WILL YOU NEED?

This system requires no special wiring or assembly. Simply
run cable straight along pipe and valves according to instructions in package, affix with premium application tape, insulate, and plug into a ground fault protected electrical outlet.

This cable comes in standard 3-foot increments (up to 18 feet),
so you’ll need to know two key dimensions to select the right
package: the length of the pipe run, including valves, to be
heated and the diameter of the pipe.

For pipe 3/4” in diameter or less, round pipe length down
to the nearest 3-foot increment. So, 7 feet of pipe would
require a 6-foot cable; 11 feet of pipe would use a 9-foot
cable.

Cable Selection Guide
Length of Pipe

DIA.

3´

4-5´

6´

7-8´

9´

10-11´

12´

13-14´

15´

16-17´

18´

19-20´

21-23´

24´

25-27´

28-29´

30´

40´

60´

80´

.9M

1.2-1.5M

1.8M

2.1-2.4M

2.7M

3-3.4M

3.7M

4-4.3M

4.6M

4.9-5.2M

5.5M

5.8-6.1M

6.4-7M

7.3M

7.6-8.2M

8.5-8.8M

9.1M

12.2M

18.3M

24.4M

3/8”—3/4”

1

1

1

1

1

1

1

1

1

1

1

1

2*

1

1

2*

1

1

1

1

(9.53 mm-19.05 mm)

AHB013

AHB013

AHB016

AHB016

AHB019

AHB019

AHB112

AHB112

AHB115

AHB115

AHB118

AHB118

AHB112

AHB124

AHB124

AHB115

AHB130

AHB140

AHB160

AHB180

1”—1 1/2”

1

2*

1

2*

1

2*

1

1

1

1

1

1

AHB115

AHB112

AHB124

2*
(1) AHB115
(1) AHB112

2*

AHB019

AHB019

2*
(1) AHB019
(1) AHB112

2*

AHB016

2*
(1) AHB016
(1) AHB019

1

AHB013

2*
(1) AHB013
(1) AHB016

1

AHB013

AHB115

AHB130

AHB140

AHB160

AHB180

(25.4 mm-38.1 mm)

AHB016

AHB112

AHB118

For pipe diameters from 3/4 to 11/2 inches, match the pipe length as closely as possible to the cable length.
For odd pipe lengths, use two cables with a combined length no more than 3 feet longer than the pipe run.
*Start cables from opposite ends of the pipe and run along opposite sides with overrun in the center.
For larger pipe diameters, contact EasyHeat for appropriate product selection.

!

WARNING: Do not spiral cable around pipe
or cross cable over itself. Do not use one
run of cable for two different pipe runs. Failure
to comply may result in overheating and fire.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2010:09:28 11:14:29-05:00
Creator                         : Adobe InDesign CS4 (6.0)
Modify Date                     : 2011:05:09 11:10:10-05:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Instance ID                     : uuid:24d659a8-796a-4618-9efe-8d6f0e6d3372
Document ID                     : xmp.did:189E8A2D68C6DF118F57CF7E2975D27B
Original Document ID            : adobe:docid:indd:dbc3a64c-afd0-11dc-ab69-f5163b249b22
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:179E8A2D68C6DF118F57CF7E2975D27B
Derived From Document ID        : xmp.did:51CB4F3A6AC2DF1180F2B06E0EEA7302
Derived From Original Document ID: adobe:docid:indd:dbc3a64c-afd0-11dc-ab69-f5163b249b22
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:D8AD24311B4EDF11B086CC2BECFA0222, xmp.iid:D9AD24311B4EDF11B086CC2BECFA0222, xmp.iid:DAAD24311B4EDF11B086CC2BECFA0222, xmp.iid:DBAD24311B4EDF11B086CC2BECFA0222, xmp.iid:DCAD24311B4EDF11B086CC2BECFA0222, xmp.iid:DDAD24311B4EDF11B086CC2BECFA0222, xmp.iid:50CB4F3A6AC2DF1180F2B06E0EEA7302, xmp.iid:51CB4F3A6AC2DF1180F2B06E0EEA7302, xmp.iid:54CB4F3A6AC2DF1180F2B06E0EEA7302, xmp.iid:55CB4F3A6AC2DF1180F2B06E0EEA7302, xmp.iid:179E8A2D68C6DF118F57CF7E2975D27B, xmp.iid:189E8A2D68C6DF118F57CF7E2975D27B, xmp.iid:199E8A2D68C6DF118F57CF7E2975D27B, xmp.iid:1A9E8A2D68C6DF118F57CF7E2975D27B
History When                    : 2010:04:22 09:36:37-05:00, 2010:04:22 09:36:37-05:00, 2010:04:22 10:01:06-05:00, 2010:04:22 10:03:25-05:00, 2010:04:22 10:05:37-05:00, 2010:04:22 10:07:44-05:00, 2010:09:17 09:45:34-05:00, 2010:09:17 09:45:34-05:00, 2010:09:17 14:10:31-05:00, 2010:09:20 10:28:05-05:00, 2010:09:22 16:05:36-05:00, 2010:09:22 16:05:36-05:00, 2010:09:22 16:06:56-05:00, 2010:09:22 16:08:05-05:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0
History Changed                 : /, /metadata, /, /, /, /, /metadata, /;/metadata, /, /, /metadata, /;/metadata, /, /
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 350.00
Manifest Placed Y Resolution    : 72.00, 72.00, 350.00
Manifest Placed Resolution Unit : Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:84F0FAB36C0E11DC97D9BB0EACDB1D21, uuid:84F0FAB36C0E11DC97D9BB0EACDB1D21, xmp.iid:B8A69F11CDC1DF119F99BFD1670E9A4C
Manifest Reference Document ID  : uuid:84F0FAB26C0E11DC97D9BB0EACDB1D21, uuid:84F0FAB26C0E11DC97D9BB0EACDB1D21, xmp.did:B6A69F11CDC1DF119F99BFD1670E9A4C
Metadata Date                   : 2011:05:09 11:10:10-05:00
Creator Tool                    : Adobe InDesign CS4 (6.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 15674 bytes, use -b option to extract)
Doc Change Count                : 71
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.0
Trapped                         : False
Page Layout                     : OneColumn
Page Mode                       : UseOutlines
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu