Stop Pipe
and Valve
Freeze-up
ForMetal
andPlastic
WaterPipes
With
Energy-saving
Thermostat
HOW TO INSTALL SYSTEM
Tochoosetherightlengthofpipefreezeprotectioncable,
cableshouldbelongenoughtorunalongbottomof
horizontalpipesandweathersideofverticalpipes(in-
cludingvalves)withoutcrossingorspiraling.Neveruse
acablelongerthanthepipeitisintendedtoprotect.
1. Refertothechartinsideoronthepackagefor
propercableselection.
2. Cablewillbeappliedstraightalongpipe,andwill
protectpipesupto1½inchesindiameter.*
3. Forpipelengthsotherthanstandardheatingcablesizes,
andover1/4inchindiameter,usetwoheatingcablesin
parallelonoppositesidesofthepipe(seeillustration).Maxi-
mum“overrun”shouldnotexceed3feet.Do not install on
pipe shorter than 3 feet long.**
4. Wraptheentirepipeandcablewithinsulation.Com-
pletetheinstallationwiththeweatherproofwrapandthe
cautionsigns.Forplasticpipe,werecommendwrapping
pipeinaluminumfoilbeforeinstallingcableforbetterheat
distribution.
PRODUCT SELECTION GUIDE
EasyHeat
DESCRIPTION
ITEM #
 AHB-013 3´LENGTH,21WATTS
 AHB-016 6´LENGTH,42WATTS
 AHB-019 9´LENGTH,63WATTS
 AHB-112 12´LENGTH,84WATTS
 AHB-115 15´LENGTH,105WATTS
 AHB-118 18´LENGTH,126WATTS
 AHB-124 24´LENGTH,168WATTS
 AHB-130 30´LENGTH,210WATTS
 AHB-140 40´LENGTH,280WATTS
 AHB-160 60´LENGTH,420WATTS
 AHB-180 80´LENGTH,560WATTS
 HCA APPLICATIONTAPE
 HCP1 CABLESENTRY
WARNING:EasyHeatrecommendsusingaground
fault protectedreceptacle.
!
C
Listed
© 2010 EasyHeat 40200-001 Rev. 5
*Forpipediameters
greaterthan1
½
inches,
pleasecontactyour
EasyHeatrepresentative.
**Fordetailsplease
contactyourEasyHeat
representative.
EasyHeatproductsareprovidedwithaLIMITEDWARRANTY:
SeeInstallation&OperationInstructionsorcontact
EasyHeatforcompletetermsandconditions.
USA Canada
2ConnecticutSouthDrive 99UnionStreet
EastGranbyCT06026 ElmiraONN3B3L7
Tel 800/537-4732 Tel 519/669-2444
Fax 800/541-7451 Fax 519/669-6419
www.easyheat.com AHBSeries
ElectricWaterPipe
Freeze
Protection
Cable
AHBHEATINGCABLE/ACCESSORIES
Stop Pipe Freeze-up
Electric Water Pipe Freeze Protection Cable
EasyHeat,theleaderinresidentialpipefreezeprotec-
tion,presentstheAHBSeriespipeheatingsystem.Pre-
assembledandready-to-install,thecablepreventspipesfrom
freezing,keepingwaterflowingto40°.Usinganenergy-
savingthermostat,AHBcablesoperateon120VoltsACand
aresuitableforuseonwater-filledplasticandmetalpipes.
Thissystemcanbeinstalledwiththeconfidencethatitwill
operateforyearswithoutrequiringservice.Allcomponents
aremadeofthehighestqualitymaterialsandaretested
duringcriticalpointsinthemanufacturingprocess.
SIMPLE TO INSTALL
Thissystemrequiresnospecialwiringorassembly.Simply
runcablestraightalongpipeandvalvesaccordingtoinstruc-
tionsinpackage,affixwithpremiumapplicationtape,insu-
late,andplugintoaground fault protectedelectricaloutlet.
INDICATOR LIGHT
TheAHBsystemincludes
apowerindicatorlight
intheplugforassur-
ancethatthesystemhas
power.
HOW MUCH CABLE WILL YOU NEED?
Thiscablecomesinstandard3-footincrements(upto18feet),
soyou’llneedtoknowtwokeydimensionstoselecttheright
package:thelengthofthepiperun,includingvalves,tobe
heatedandthediameterofthepipe.
TheAHBSeriessystemiseasytobuyandtoinstall,engineered
in3-footincrements(upto18feet)toaccommodatemanypipe
lengthswithdiametersupto1½inches.Simplyrunthecable
straightalongthepipeandvalvesaccordingtotheincluded
instructions,affixwithourpremiumapplicationtapeandinsula-
tion,thenplugintoaground fault protectedelectricaloutlet.
Whenitcomestopipefreezeprotection,staywiththeleader–
EasyHeat.
Keepswaterflowingdownto40°F(40°C)
Pre-assembled,readytoinstall
Withpowerindicatorlight
Withenergy-savingthermostat
Forpipe3/4”indiameterorless,roundpipelengthdown
tothenearest3-footincrement.So,7feetofpipewould
requirea6-footcable;11feetofpipewouldusea9-foot
cable.
DIA.
Length of Pipe
.9M
4-5´
1.2-1.5M
1.8M
7-8´
2.1-2.4M
2.7M
10-11´
3-3.4M
12´
3.7M
13-14´
4-4.3M
15´
4.6M
16-17´
4.9-5.2M
18´
5.5M
19-20´
5.8-6.1M
21-23´
6.4-7M
24´
7.3M
25-27´
7.6-8.2M
28-29´
8.5-8.8M
30´
9.1M
40´
12.2M
60´
18.3M
80´
24.4M
1
AHB013
1
AHB013
1
AHB016
1
AHB016
1
AHB019
1
AHB019
1
AHB112
1
AHB112
1
AHB115
1
AHB115
1
AHB118
1
AHB118
2*
AHB112
1
AHB124
1
AHB124
2*
AHB115
1
AHB130
1
AHB140
1
AHB160
1
AHB180
1
AHB013
2*
AHB013
1
AHB016
2*
(1) AHB013
(1) AHB016
1
AHB019
2*
AHB016
1
AHB112
2*
(1) AHB016
(1) AHB019
1
AHB115
2*
AHB019
1
AHB118
2*
(1) AHB019
(1) AHB112
2*
AHB112
1
AHB124
2*
(1) AHB115
(1) AHB112
2*
AHB115
1
AHB130
1
AHB140
1
AHB160
1
AHB180
3/8”—3/4”
(9.53 mm-19.05 mm)
1”—1 1/2”
(25.4 mm-38.1 mm)
For pipe diameters from 3/4 to 11/2 inches, match the pipe length as closely as possible to the cable length.
For odd pipe lengths, use two cables with a combined length no more than 3 feet longer than the pipe run.
*Start cables from opposite ends of the pipe and run along opposite sides with overrun in the center.
For larger pipe diameters, contact EasyHeat for appropriate product selection.
WARNING: Do not spiral cable around pipe
or cross cable over itself. Do not use one
run of cable for two different pipe runs. Failure
to comply may result in overheating and fire.
!
Cable Selection Guide