280523 Catalog
136144-Catalog 136144-Catalog 136144-Catalog Batch9 unilog cesco-content
2014-07-05
: Pdf 280523-Catalog 280523-Catalog 782683 Batch5 unilog
Open the PDF directly: View PDF
.
Page Count: 149
| Download | |
| Open PDF In Browser | View PDF |
INTRODUCTION TABLE OF CONTENTS Company Profile . . . . . . . . . . . . . . . . . . . . 2-3 Technological Development . . . . . . . . . . . . 4-5 MR16 LED Nexus® System . . . . . . . . . . . . . . . . . . . . . 6-7 Spec Grade Products Table of Contents. . . . . . . . . . . . . . . . . . . . 8-9 What are Spec Grade Products . . . . . . . . . . 10 Architectural Table of Contents. . . . . . . . . . . . . . . . . . . . . 11 Lux-Ray™ LED Series . . . . . . . . . . . . . . 12-13 Revelation™ Series . . . . . . . . . . . . . . . . . . . 14 Mini-Revelation™ Series . . . . . . . . . . . . . . . 15 PS Series . . . . . . . . . . . . . . . . . . . . . . . . . . 16 RS Series . . . . . . . . . . . . . . . . . . . . . . . . . . 17 TS Series . . . . . . . . . . . . . . . . . . . . . . . . 18-19 EFR2 Distinction Series . . . . . . . . . . . . . . . . 20 GS Series . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Prestige™ Edge-Lit Series . . . . . . . . . . . 22-23 Prestige™ X40 Edge-Lit Series . . . . . . . . . . 24 Prestige™ DX Series . . . . . . . . . . . . . . . . . . 25 Prestige™ Floor Proximity Series . . . . . . 26-27 Commercial Table of Contents. . . . . . . . . . . . . . . . . . . . . 29 Premier™ Battery Series . . . . . . . . . . . . . . 30 Premier™ Combo Series . . . . . . . . . . . . . . . 31 Premier™ Exit Series . . . . . . . . . . . . . . . . . . 32 Provider™ PRO-2N/PRO-3N Series . . . . . . 33 EC-2 Series . . . . . . . . . . . . . . . . . . . . . . . . . 34 ECC and ECM Series . . . . . . . . . . . . . . . . . 35 JC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 JA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 JS Series . . . . . . . . . . . . . . . . . . . . . . . . 38-39 LSE Series . . . . . . . . . . . . . . . . . . . . . . . . . . 40 LC Series. . . . . . . . . . . . . . . . . . . . . . . . . . . 41 LS Series . . . . . . . . . . . . . . . . . . . . . . . . 42-43 24 LS & 24 LC Series . . . . . . . . . . . . . . . . . 44 X10 LED Series . . . . . . . . . . . . . . . . . . . . . . 45 Prestige™ Recessed Economizer Series . . . 46 Prestige™ Economizer Series . . . . . . . . . . . 47 Preceptor™ Die-Cast Series . . . . . . . . . . . . 48 Preceptor™ Recessed Series . . . . . . . . . . . 49 Preceptor™ Remote Capacity Series . . . . . 50 Special Wording Configurations . . . . . . . . . . 51 Industrial Table of Contents. . . . . . . . . . . . . . . . . . . . . Hazardous Locations . . . . . . . . . . . . . . . . . . Survive-All™ SV Series . . . . . . . . . . . . . . . . Survive-All™ SVX Combo Series . . . . . . . . . Survive-All™ SVX Exit Series . . . . . . . . . . . . Survive-All™ EF39 & EF40 Series . . . . . . . . HZM Series, Class 1 Division 2 . . . . . . . . . . Survive-All™ SVH Series, . . . . . . . . . . . . . . Class 1 Division 2 Survive-All™ SVXH Series, . . . . . . . . . . . . . Class 1 Division 2 Survive-All™ SVX-HZ Series, . . . . . . . . . . . . 53 54 55 56 57 58 59 60 Class 1 Division 2 Survive-All™ EF41 Series, . . . . . . . . . . . . . . 63 Class 1 Division 2 IL Series . . . . . . . . . . . . . . . . . . . . . . . . 64-65 KS Steel Series . . . . . . . . . . . . . . . . . . . 66-67 KS Series . . . . . . . . . . . . . . . . . . . . . . . 68-69 EXC Series . . . . . . . . . . . . . . . . . . . . . . 70-71 EFEP Series. . . . . . . . . . . . . . . . . . . . . . . . . 72 EFXP Series. . . . . . . . . . . . . . . . . . . . . . . . . 73 EverLite™ Self Luminous Series . . . . . . . . . 74 Emergency Ballasts Remote Fixtures Central & Inverter Systems Table of Contents. . . . . . . . . . . . . . . . . . . . . Lux-Ray™ LED Remote Series . . . . . . . . . . Literay™ Series . . . . . . . . . . . . . . . . . . . . . . Revelation™ Remote Series. . . . . . . . . . . . . Mini-Revelation™ Remote Series . . . . . . . . . Distinction™ EF150 Series . . . . . . . . . . . . . Distinction™ Recessed Designer Series . . . Surface Mounted EF9 Series . . . . . . . . . . . . Surface Mounted EF10 Series . . . . . . . . . . . Surface Mounted EF14 Series . . . . . . . . . . . Surface Mounted EF18 Series . . . . . . . . . . . Surface Mounted EF23 Series . . . . . . . . . . . Surface Mounted EF24 Series . . . . . . . . . . . Surface Mounted EF28 Series . . . . . . . . . . . Surface Mounted EF32 Series . . . . . . . . . . . Recessed Mounted EF13 & EF17 Series . . . Recessed Mounted EF15 Series. . . . . . . . . . Recessed Mounted EF21R Series . . . . . . . . Recessed Mounted EF35 Series . . . . . . . . . Weather Proof EF11 Series . . . . . . . . . . . . . Weather Proof EF11X Series . . . . . . . . . . . . Survive-All™ EF39 & EF40 Series. . . . . . . . . Survive-All™ EF41 Series. . . . . . . . . . . . . . . 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 Distributor Select What are Distributor Select Products . . . . . Table of Contents . . . . . . . . . . . . . . . . . . . Prestige™ Thin Die-Cast . . . . . . . . . . . . . . Total™ Edge-Lit Series . . . . . . . . . . . . . . . Micro LED Battery Series . . . . . . . . . . . . . . Micro LED Combo Series. . . . . . . . . . . . . . EF43D & EF44D Series. . . . . . . . . . . . . . . . DLM-2 Series . . . . . . . . . . . . . . . . . . . . . GS Series . . . . . . . . . . . . . . . . . . . . . . . . . EL-2SQ Series . . . . . . . . . . . . . . . . . . . . . . ELX400 SQ Series . . . . . . . . . . . . . . . . . . . EL-2MRS & 12EL-2MRS50 Series . . . . . . . ELX-MRS Series . . . . . . . . . . . . . . . . . . . . ELX Series . . . . . . . . . . . . . . . . . . . . . . . . . Quick Switch Series. . . . . . . . . . . . . . . . . . 61 62 1 100 101 102 103 104 105 105 106 107 108 109 110 111 112 113 Table of Contents . . . . . . . . . . . . . . . . . . . FPDL Series . . . . . . . . . . . . . . . . . . . . . . . FPS Series. . . . . . . . . . . . . . . . . . . . . . . . . FPS-R & FPS-T Series . . . . . . . . . . . . . . . . FTS Series . . . . . . . . . . . . . . . . . . . . . . . . . ELMR-E Series. . . . . . . . . . . . . . . . . . . . . . Emergency Ballast Reference Chart. . . . . . 115 116 117 118 119 120 121 Table of Contents. . . . . . . . . . . . . . . . . . . . 123 Mini-Inverter . . . . . . . . . . . . . . . . . . . 124-125 Systems Feature & Benefits . . . . . . . . 126-127 Compact Series. . . . . . . . . . . . . . . . . 128-129 IPS 1-Ph Series . . . . . . . . . . . . . . . . . 130-131 FTC 1-Ph Series. . . . . . . . . . . . . . . . . 132-133 3FTC 3-Ph Series. . . . . . . . . . . . . . . . 134-135 FTC3R & 3FTC3R Series . . . . . . . . . . . . . . 136 Systems Options Series. . . . . . . . . . . . . . . 137 Control Panel & Display Functions . . . . . . . 138 Central System Request Data. . . . . . . . . . . 139 Accessories and General Information Table of Contents . . . . . . . . . . . . . . . . . . . 141 Wire Guards . . . . . . . . . . . . . . . . . . . 142-143 Unit Accessories . . . . . . . . . . . . . . . . . . . . 144 Mounting Plates. . . . . . . . . . . . . . . . . . . . . 145 Lamp Data . . . . . . . . . . . . . . . . . . . . 146-147 Wire Size Guide . . . . . . . . . . . . . . . . . . . . . 148 National Electrical Code . . . . . . . . . . . 149-151 Life Safety Code . . . . . . . . . . . . . . . . 152-154 Limited Warranty . . . . . . . . . . . . . . . . . . . . 155 Product Index . . . . . . . . . . . . . . . . . . . . . . 156 INTRODUCTION NORTH AMERICAN Manufacturing Facility Thomas & Betts has unique North American manufacturing and production capabilities that allow Emergi-Lite® to produce exactly what we need when we need it, without waiting for big production runs or imported goods to arrive. Leading-Edge Research And Development Advanced Circuit Board Production The multi-disciplinary in-house research and development team at Thomas & Betts/Emergi-Lite® includes many individuals with over twenty-five years of experience in the emergency lighting industry. Our highly skilled professional electrical and mechanical engineers, designers, and technicians pioneer innovative emergency lighting solutions by using state-of-the-art technology in all specialties from mechanical design to operating system software, lighting design, RF and power electronic design and LED drivers. Unique requests from customers for specific applications are managed in-house with our engineering service capabilities. We implement safety and quality into each product starting at the initial concept and design. To ensure that each unit is code-compliant, and meets the Emergi-Lite® quality standards including easy installation and long-term reliability, we create our own specialized testing equipment. Thousands of universal SMT (surface mount technology) boards and TH (through-hole) insertion boards are produced daily at the Thomas & Betts manufacturing facility on technologically advanced printed circuit board production lines. Our ROHS-compliant wave soldering machine meets lead-free criteria, and every station is ESD (electro-static discharge) protected to eliminate static hazards. Trained according to IPC standards, our skilled production personnel ensure quality by using board traceability and tracking software. High productivity and quality are ensured with the use of automatic silicone coating application and insertion equipment. The new AOI (automated optical inspection) machine added to the Thomas & Betts printed circuit board operation in 2012 is one of the first of its kind in use in North America. The Thomas & Betts North American facility is an emergency lighting center of excellence thanks to the commitment, expertise, and creativity of every employee. 2 Manufacturing Facility With everything under one roof, we have total control over service, quality and lead time, and we can ensure that our strict quality standards are met at every stage in the process from design to assembly to order completion. Production & Quality Control Streamlined & Environmentally Conscious Our electro-mechanical assembly lines are optimized for highly efficient low-volume, high-mix production runs with thousands of final assemblies produced on a daily basis. Color matching, exact wording, specific punching, and other special requests can be completed quickly using our on-site painting capabilities and machine shop. Strategically located warehouses throughout the United States hold large inventories ready to ship for fast delivery to customers across the country. A Sustainable Development policy is in effect at the Thomas & Betts manufacturing facility to minimize the environmental impact and reduce the carbon footprint of operations. Reductions in usage of electricity and natural gas, packaging, pallets, water, and water bottles have already been accomplished through a series of initiatives. Forward-looking objectives include increased pallet recycling, paper usage reductions, and the implementation of an eco-delivery schedule. All central power systems undergo high-voltage, high-amperage power outage simulations to test for each customer’s specific requirements, and every order must pass functional testing and quality inspection. Specialized in-house facilities such as temperature and humidity controlled environments; a dark room for color contrast measurement; wall, ceiling and suspended ceiling installation simulations; and cycle testing automation are used to ensure quality. Since 2001, the Thomas & Betts manufacturing facility has been ISO 9001 compliant. 3 INTRODUCTION NORTH AMERICAN INTRODUCTION MR16 LED Emergency Lighting MR16 LED Illumination MR16 LED Lamp Benefits With the remarkable technology technological developments in the last few years, the light-emitting diode (LED) is becoming the preferred solution in low- and medium-power lighting applications. The emergency lighting industry is no exception: today virtually every new product introduced to market includes “white” LEDs for emergency illumination. • UL- recognized components CSA C22.2 No. 141 certified. • Energy-efficient LED MR16 lamp provides equivalent lighting performance to a much higher watt halogen MR16 lamp. • Reduces required battery capacity by 75-85%, providing necessary illumination with fewer remote heads and battery units for project cost savings. Extremely efficient and long-lasting, LED lamps become the natural alternative to incandescent lamps due to three main advantages: • Small profile, compact white lighting is ideal for architectural applications. • lamp efficacy: 50 - 90 lumens per watt compared to 15 - 30 lumens per watt of the best halogen lamp. • Vibration-resistant LED stands up to industrial environments. • operational life: 30,000+ hours, equivalent to a lifetime warranty in emergency lighting. • Ideal for indoor and outdoor use. • lower lamp temperature 80-120°C (176-248°F) is a huge benefit for lighting in hazardous locations. 200-Lumen 4W MR16 LED Spacing Leading the technology trend, Emergi-Lite® offers a complete series of 4W MR16 LED lamps available for all the standard battery voltages: 6V, 12V, 24V and 120V. With up to 30,000 hours of operational life and a luminous flux of typically 200 lumens, they are available with most emergency heads designed to hold an MR16 lamp and meet the majority of illumination specifications. For example: one pair of LED emergency heads installed at a height of 7.5 ft illuminates a 6 ft by 40 ft path of egress. 40 ft Compared to halogen lamps (16-20W), these 4W MR16 LED lamps illuminate the same area of egress during an emergency situation by using 75% less power. This has a direct impact on the battery size, reducing the back-up capacity needs by 75%. Consequently, it also reduces the total cost of the application, with the use of smaller battery capacity units, the possibility of using fewer fixtures due to superior illumination, thus also reducing electrical wiring, and the environmental footprint. . 6 ft. Spacing 340-Lumen 5W MR16 LED Keeping pace with technology, in 2012 we introduced a 12V-5W MR16 LED lamp. With a typical luminous flux of 340 lumens, this lamp has the same lighting performance as a 20W high-output halogen MR16. A twin emergency head installed at a height of 7.5 ft illuminates more than 70ft of path of egress. 70 ft . 6 ft. 540-Lumen 6W MR16 LED Spacing A 6W MR16 LED lamp delivers 540 lumens for an average spacing in emergency lighting of 100 feet with an efficacy of 91.9 Lm/w, it is over 6 times the efficacy of a MR16 35W halogen with similar light output. This lamp can deliver the highest linear foot of illumination per watt on a path of egress! (spacing in feet / watt) 16.7 ft compare to 2.7 ft for a MR16 35W. 100 4 ft. 6 ft. Emergency Lighting Case Study: Fewer MR16 LED units required • Reduced Lamp Replacement Costs. LED lamps have a 30,000+ hour lamp life compared to only a few hundred hours typical with incandescent lamps. Emergency lighting units with MR16 LED lamps provide the same illumination at floor level using significantly with many additional benefits: • Reduced Environmental Impact, with less product materials, less batteries, less transportation, less packaging, less labor, and less waste. • Reduced Installation Costs, due to reduced product and labor requirements. • Reduced Energy Costs, keeping fewer batteries charged at full capacity to be ready to respond to an emergency situation at any time. • Reduced Maintenance and Testing Costs, with fewer units to maintain and test in the Emergency Lighting System. Compare Where the building code requires an average of 1 foot-candle and a minimum of 0.1 foot-candle at floor level along the path of egress on a 150 ft x 9 ft x 9 ft corridor with an egress door at one end, a 150 ft x 6 ft path of egress, and a 7.5 ft unit mounting height, using high-efficiency LED lamps can reduce the emergency lighting units required from 9 dual-head units down to only 2 dual-head units: 9 twin lamp heads required. Only 5 dual lamp heads required. Standard wedge-base 9W incandescent lamp 4W MR16 LED lamps Standard Emergency Lighting Units with 9W wedge-base incandescent lamps Same Standard Emergency Lighting Units with 4W MR16 LED Lamps LAMP SUFFIX VOLTAGE Only 3 dual lamp heads required. LI VOLTAGE 12 REPLACEMENT # 6 4 WATTAGE 130 580.0097-E LG 12 4 170 580.0093-E LL 24 4 200 580.0098-E LUMENS REPLACEMENT # 540 580.0106-E Only 2 dual lamp heads required. 5W MR16 LED lamps LAMP SUFFIX LUMENS LA NEW! 6W MR16 LED lamps WATTAGE 5 LUMENS REPLACEMENT # 340 580.0104-E LAMP SUFFIX LJ 5 VOLTAGE 12 WATTAGE 6 INTRODUCTION MR16 LED INTRODUCTION NEXUS® EMERGENCY LIGHTING Management System Manage Testing with Nexus® to Save Time and Costs Nexus® is a real-time monitoring system that manages the status of your entire emergency lighting and exit sign system from a central control unit. Nexus® runs diagnostics, performs required monthly and annual functional tests, generates maintenance logs and runs compliance reports. Available in wired or wireless (RF) versions, Nexus® installations often pay for themselves in less than two (2) years. In addition to operational savings, Nexus® helps increase system reliability and performance and reduces the risk of failed inspections. One building or a group of properties under the same management can be monitored with Nexus®. Maximize System Availability By allowing maintenance personnel to easily maintain and monitor the emergency lighting system without having to manually check each unit, Nexus® reduces the hours required to disrupt the power supply for inspections. With Nexus®, monthly tests and reports on the status of all emergency lights and exit signs can be done individually, in groups, or together. Advantages of the Nexus® system include saving labor; maximizing system availability by testing units in groups and stages rather than setting all units in recovery mode; and the convenience of self-monitoring. Nexus® indicates the location of a faulty unit and reports it instantly without requiring a manual search. Are you prepared for a safety inspection? Building & Life Safety Codes oblige building owners/managers to ensure the safe evacuation of a building in the event of an emergency. In the interest of public safety, building owners/managers must meet the outlined requirements for exit signs and emergency lighting equipment, including the following: • Conduct a discharge test every month • Conduct functional tests annually • Keep a log book of maintenance information Complying with these requirements can be labor intensive and costly, especially in large buildings where testing every emergency light requires many man-hours. Disrupting the power supply during lengthy inspections can also put public safety at risk. 6 Management System Update Status Instantly Nexus® passes messages both to and from the emergency units to instruct the units to perform all mandatory testing by communicating between the emergency units and a centrally located controller. Nexus® is a proven system supported by a 5-year warranty, and can contribute to LEED certification and support green building initiatives. Small System Example In a system of less than 100 units it is most likely that the only hardware required, other than the emergency units themselves, is a controller. All communication would occur wirelessly and installation would not vary greatly from a non-monitored system. Once the units are in place, the system will establish the mesh network. The building itself could be quite large as each unit only needs to be able to communicate with its close neighbors and does not need to communicate directly with the controller. Large System Example The Nexus® RF system has been designed to be extremely flexible and provide a range of system options. Each large site will need to be assessed for the best system solution with the assistance of Thomas & Betts technical staff. The basic Nexus® RF system is designed to run on an Ethernet network which is present in most modern buildings. However through a range of interface cards, the backbone of the network could be WLAN. As with the small system example, site performance will be optimized through the careful selection and placement of Area Controller Routers and the Area Controller to form efficient clusters. Building layout and materials will also play some role in determining the best solution to deliver a highly effective means of meeting testing and maintenance requirements. 7 INTRODUCTION NEXUS® EMERGENCY LIGHTING INTRODUCTION SPEC GRADE PRODUCTS Table of Contents COMMERCIAL ARCHITECTURAL 12-13 Premier™ Battery Series 30 Revelation™ Series 14 Premier™ Combo Series 31 Mini-Revelation™ Series 15 Premier™ Exit Series 32 PS Series 16 Provider™ PRO-2N Series 33 RS Series 17 EC-2/ECX-2 Series 34 TS Series 18-19 ECC & ECM Series 35 JC Series 36 Lux-Ray™ LED Series EFR2 Series 20 GS Series 21 JA Series 37 22-23 JS Series 38-39 Prestige™ Edge-Lit Series Prestige™ X40 Series 24 Prestige™ DX Series 25 Prestige™ Floor Proximity Series 26-27 LSE Series 40 LC Series 41 LS Series 42-43 24 LS & 24 LC Series 8 44 Table of Contents X10 LED Series 45 Survive-All™ SVH Series 60 Prestige™ Recessed Economizer Series 46 Survive-All™ SVXH Series 61 Prestige™ Economizer Series 47 Survive-All™ SVXHZ Series 62 Preceptor™ Die-Cast Series 48 Survive-All™ EF41 Series 63 Preceptor™ Recessed Series 49 IL Series 64-65 Preceptor™ Remote Capacity Series 50 KS Steel Series 66-67 Special Wording Configuration 51 KS Series 68-69 EXC Series 70-71 INDUSTRIAL Hazardous Location 54 Survive-All™ SV Series 55 Survive-All™ SVX Combo Series 56 Survive-All™ SVX Exit Series 57 Survive-All™ EF39 & EF40 Series 58 HZM Series 59 9 EFEP Series 72 EFXP Series 73 Ever-Lite™ Self-Luminous Series 74 INTRODUCTION SPEC GRADE PRODUCTS INTRODUCTION What are SPEC GRADE PRODUCTS? Specification Grade For demanding applications such as high-visibility areas in retail spaces, high-traffic areas in hotel lobbies, and the intense heat in foundries and mills, Emergi-Lite® Specification Grade products provide a vast array of specialty emergency lighting equipment and exit signs. Architects, contractors and designers will find a selection of modern styles and mounting options to suit virtually any application where emergency lighting and exit signs must be aesthetically pleasing as well as functional. The high-quality die-cast aluminum, steel, and thermoplastic housings on Emergi-Lite® Specification Grade products can be provided in all colors and finishes to complement any interior. A choice of battery options, lamp types, and configurations are available to meet your photometric requirements and specifications. For heavy-duty industrial areas with stringent requirements, NEMA-certified models, NSF-approved products, explosionproof units, and more are available for highly demanding locations. Make Emergi-Lite® your source for modern, stylish, highperformance emergency lighting equipment and exit signs. SPEC GRADE SPEC GRADE ARCHITECTURAL Table of Contents Revelation™ Series 14 Mini-Revelation™ Series 15 PS Series 16 RS Series 17 TS Series 18-19 EFR2 Series 20 GS Series 21 Prestige™ Edge-Lit Series 22-23 Prestige™ X40 Series 24 Prestige™ DX Series 25 Prestige™ Floor Proximity Series 11 12-13 26-27 ARCHITECTURAL Lux-Ray™ LED Series TYPE: SPEC GRADE NEMA-3R NOTES: Lux-Ray™ LED Series Features Dimensions Dimensions are approximate and subject to change. • Die-Cast aluminum housing, available in four finishes: dark bronze, off-white, black, and platinum gray • Nema-3R rated for indoor/outdoor wet, damp & cold locations: -20 to 50°C (-4 to 122°F), SD Model -20 to 40°C (-4 to 104°F), ACSD Model • Wall-mount installation on various junction boxes or via rigid conduit • Patent-Pending design for easy installation: wall-mount back plate includes electrical wire box with snap-on connector • Patent-Pending light engine: four power LEDs with redundant connections and wide beam • Clear polycarbonate lens of reduced size (3” X 1.5”), shock absorbent and UV-resistant • Battery: environmentally friendly high-temperature rated, Nickel-Metal Hydride technology • Power consumption in stand-by: less than 5W • Optional self-test and diagnostic functions, operated by micro-controller • 5-year limited warranty 3” 6-5/8” 9-1/2” ARCHITECTURAL CATALOG #: Patent-Pending 3” Optional Features • Cold weather: -40°F / -40°C • Forward-throw light distribution, for applications of outdoor exit discharge (OSHA 1910.36) • High-lumen output: 25 to 50% additional level of illumination compared to the regular unit • Dual-mode operation: normal lighting and/or emergency lighting with separate AC inputs • Photo-switch: dusk-to-dawn control of normal lighting • Remote test: infrared remote control (keypad ordered separately) • Time Delay: 5, 10, 15 minutes Window for photo-switch (optional) Power Consumption AC SPECS: 120/277VAC Normal lighting Model Type Emergency lighting Power (max) Current (max) Current (max) 6-12VDC remote Power (max) Power (max) AC, 2AC, ACDC, DC 0.12/0.08A 12W 0.12/0.08A 12W 8W AC, 2AC, ACDC, DC, -H 0.18/0.11A 18W 0.18/0.11A 18W 14W ACSD, SD, SD-H 0.12/0.06A 12W 0.05/0.02A 5W n/a* 0.15/0.07A 16W 0.22/0.10A 24W SD-CW - - ACSD-CWP, -CWRC n/r* * Note: Only unswitched AC input; normal lighting with photo-switch or remote control 12 TYPE: CATALOG #: SPEC GRADE NOTES: Die-Cast Aluminum LED Emergency Lighting Photometry performance Whether installed indoors or outdoors, with spacing measurements for a single unit or between two units center-to-center, the Camray® Series LED delivers a stable and consistent illumination making it easy to specify in a wide range of applications. The outstanding spacing of illumination ranges from 50 to 70 feet for standard units (wide beam) and from 40 to 50 feet with the forward-throw beam option. TABLE A: SPACING FOR NFPA101 (AVERAGE = 1FC, SEE NOTE) TABLE B: SPACING FOR MINIMUM ILLUMINATION = 1FC Model Type ARCHITECTURAL Average of 1 foot-candle Minimum of 1 foot-candle Mouting Height Model Type Width X Lenght (ft) Single Unit Mouting Height Width X Lenght (ft) Single Unit Center-To-Center Center-To-Center Standard 9’ 4’ x 28’ 4’ x 32’ Standard 9’ 6’ X 50’ 6’ X 50’ With option -H 11’ 4’ x 32’ 4’ x 40’ With option -H 11’ 6’ X 60’ 6’ X 60’ With option -FT 12’ 4’ x 22’ — With option -FTH 15’ 4’ x 27’ — With option -FT 12’ 6’ X 40’ — With option -FTH 15’ 6’ X 50’ — 3’ X 70’ Forward Throw Wide Beam 10’ um inim 1fc m 1fc m inim 20’ e erag v 1fc a 1fc average 50’ 40’ um 28’ 9’ 6’ 6’ How to Order COLOR B= Black BZ= Dark bronze OW= Off-white PG= Platinum gray SERIES LUX= Lux-Ray LED MODEL SD= Self-Powered & diagnostic [-4... 122°F (-20… 50°C)] ACSD= Dual-mode AC / Self-Powered [-4... 104°F (-20… 40°C)] OPTIONS -CW= Cold weather [-40… 86°F (-40…30°C) N/A with option -H] -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -FT= Forward throw lighting -H= High lumen output (max. 86°F/30°C; model SD only) -P= Photocell Test Switch (ACSD only) -RC= Remote control - infrared* * Remote control keypad (TB-RC1-E) ordered separately Example: BZLUXACSD-RC 13 TYPE: CATALOG #: SPEC GRADE NOTES: US Revelation™ Series Virtually Invisible Emergency Lighting Dimensions Dimensions are approximate and subject to change. • Fully concealed in open cavity walls or ceiling • Only visible when needed: during a power failure • Each unit comes with two (2) MR16 halogen lamps ranging from 12 to 50W each or 2 MR16 style LED lamps • The Self-Powered unit is contained in a heavy-duty galvanized steel back box that can be concealed in the wall or ceiling and includes a combined test switch and pilot light that is accessible through the frame • The normally exposed parts of the unit (flat door and frame) are covered with a high-quality powder-coated, textured off-white finish that integrates well with most wall and ceiling paints. The surface finish can also be customized on site with paint, wallpaper or other coverings • Power requirements: 120/277VAC, 60Hz, 0.25/0.12A • PulsePlus Charger circuitry offers 120/277VAC 60Hz, 0.25/0.12A, automatic charger, built around a micro-controller integrated circuit. Circuit standard features include current limiting, temperature-compensated cut-off voltage, brownout transfer, low-voltage battery disconnect and battery lock out (prevents activation in DC mode until initial AC activation) • Special bar hangers for installation in sheet rock or T-bar ceilings are included. The included electrical junction box can be installed on a wall stud or ceiling beam with a simple U-shape bracket • 5-year warranty on electrical parts (motor, electronic circuitry). Each unit is fully computer-tested and aligned mechanically for optimum operation Charger & Battery Compartment: For use in walls or ceilings with a cavity, not for use in block walls or solid ceilings. 9-1/8” 7-7/8” 5-1/2” 7-1/4” 3-7/16” 23-7/8” ARCHITECTURAL Features Diagnostic/Self Test Feature (optional) Diagnostic/Self-Test circuitry is optional on all Self-Powered models. This circuitry is programmed to ensure equipment readiness and reliability by continuously monitoring every critical function of the unit. If a problem occurs, the pilot light located on the front of the unit will change color from solid green to flashing red, indicating a fault. A detailed diagnostic legend is available on the door back and provides fault identification (battery, charger circuitry, lamps) for maintenance personnel. The self-test feature will simulate a power loss for a minimum of 30 seconds every 30 days, 30 minutes every 6 months and 90 minutes annually. Accessories (order as a separate item) DESCRIPTION Maximum Input Current RTS Remote Text Switch (plastic face plate) RTS-1 Unit Rating Power Consumption Model SUFFIX Remote Test Switch (metal face plate) Input Power Watts to 87-1/2% of rated battery voltage* Model Stand-By* RTM40, RTN40 Input Current Input Power 1-1/2 hrs 40 2 hrs 4 hrs 30 24 8 hrs - 120V 0.25A 30W 0.1A 11W RTM70, RTN70 70 50 40 24 277V 0.12A 30W 0.05A 11W RTM100, RTN100 100 70 50 40 * National Electrical Code Specification * Stand-by power consumption is 50% lower for Lead-Calcium batteries. How to Order Battery Unit SERIES RT BATTERY TYPE M= Lead-Cadmium N= Ni-Cd UNIT CAPACITY 40= 12V-40W 70= 12V-70W 100= 12V-100W LAMP TYPE/WATTAGE -2(12)= 12W, MR16 each head -2(20)= 20W, MR16 each head -2(35)= 35W, MR16 each head -2(50)= 50W, MR16 each head -2 (20H)= 20W, MR16 high lumen output -2 (35H)= 35W, MR16 high lumen output OPTIONS -2 (50H)= 50W, MR16 high lumen output -2 (LG)= 12V-4W, MR16 LED -2 (LI)= 12V-5W, MR16 LED -2 (LJ)= 12V-6W, MR16 LED AD= Advanced Diagnostics (audible)* ADNA= Advanced Diagnostics (non-audible)* DL= Damp Location** D1= Time Delay (5 minutes) D2= Time Delay (10 minutes) D3= Time Delay (15 minutes) X= Back box shipped separately * Available on all models except Ni-Cd 100W ** Minimum lamp load required: 20% of unit capacity Example: RTM100-2(50)-D3 AC Remote Fixture SERIES RTG= Remote AC Generator INPUT VOLTAGE 1= 120VAC, 60Hz 2= 277VAC, 60Hz # OF LAMPS -2= Two lamps standard LAMP TYPE/WATTAGE (LG)= 12V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LJ)= 12V-6W, MR16 LED (12)= 12W each head (20)= 20W each head Example: RTG2-2(LG)-DL 14 (35)= 35W each head (50)= 50W each head (20H)= 20W, high lumen output (35H)= 35W, high lumen output (50H)= 50W, high lumen output OPTIONS -DL= Damp Location X= Back box shipped separately TYPE: CATALOG #: SPEC GRADE NOTES: US Mini-Revelation Series ™ THE UNSEEN SOLUTION Virtually Invisible Emergency Lighting Features Dimensions Dimensions are approximate and subject to change. Mounting Bracket 17-5/8” 7” 5-1/4” 9-1/8” 7-3/4” Complete Unit Installed Unit Unit Rating Accessories (order as a separate item) DESCRIPTION SUFFIX Remote Test Switch (metal face plate) RTS Remote Text Switch (plastic face plate) RTS-1 Watts to 87-1/2% of rated battery voltage* Model MRT_40 1-1/2 hrs 40 2 hrs 3 hrs 30 24 4 hrs - * National Electrical Code Specification Power Consumption Model Maximum AC Input 120VAC MRT40 MRTG Stand-By (Ni-Cd, NiMH)* Input Current 0.25A Input Power 30W Input Current Input Power 0.1A 11W 277VAC 0.12A 30W 0.05A 11W 120VAC 0.95A 110W** – – 277VAC 0.45A 110W** – – * Stand-by power consumption is 50% lower for Lead-Calcium batteries ** Maximum power when equipped with 2 x 50W lamps (generator unit) How to Order SERIES BATTERY TYPE UNIT CAPACITY AC INPUT LAMP TYPE/WATTAGE OPTIONS Battery Unit= MRT M= Lead-Calcium N= Nickel-Cadmium H= Nickel-Metal Hydride 40= 12V-40W Blank= 120/277VAC -2 (12)= 12W each head -2 (20)= 20W each head -2 (20H)= 20W, high lumen output -2 (LG)= MR16 LED, 12V-4W -2 (LI)= MR16 LED, 12V-5W -2 (LJ)= MR16 LED, 12V-6W -AD= Advanced Diagnostics (audible)* -ADNA= Advanced Diagnostics (non-audible)* -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -DL= Damp Location (only MRTN40, MRTH40) Generator Unit= MRT G= Remote AC generator Blank= Max. 100W 1= 120VAC 2= 277VAC -2 (12)= 12W each head -2 (20)= 20W each head -2 (35)= 35W each head -2 (50)= 50W each head -2 (20H)= 20W, high lumen output -2 (35H)= 35W, high lumen output -2 (50H)= 50W, high lumen output -2 (LG)= 12V-4W, MR16 LED -2 (LI)= 12V-5W, MR16 LED -2 (LJ)= 12V-6W, MR16 LED -DL= Damp Location * Minimum lamp load required: 20% of unit capacity Example: MRTM40-2(20)-ADNA 15 ARCHITECTURAL • Each unit comes with two (2) MR16 halogen lamps or 2 MR16 style LED lamps • The Self-Powered battery unit is contained in a heavy-duty galvanized steel back box that can be concealed in the wall or ceiling and includes a combined test switch and pilot light that is accessible through the frame • The normally exposed parts of the unit (flat door and frame) are covered with a high-quality powder-coated, textured off-white finish that integrates well with most wall and ceiling paints. The surface finish can also be customized on site with paint, wallpaper or other coverings • Power requirements: 120/277VAC, 60Hz, 0.25/0.12A • PulsePlus Charger - this automatic charger is built around a microcontroller integrated circuit. Circuit standard features include current limiting, temperature-compensated cut-off voltage, brownout transfer, low-voltage battery disconnect and battery lock out (prevents activation in DC mode until initial AC activation) • The equipment includes an electrical junction box and can be installed on a wall stud or ceiling beam with a simple U-shape bracket. • Evaluated to UL 924 Standard • 5-year warranty on electrical parts (motor, electronic circuitry). Each unit is fully computer-tested and aligned mechanically for optimum operation • AD or ADNA options include includes a Time Delay function. If needed, it can be enabled/disabled in the field or it can be preset at the factory by including the suffix AD-D_ or ADNA-D_ TYPE: CATALOG #: SPEC GRADE NOTES: PS Series 6 and 12 Volt Square Shooter ARCHITECTURAL Features Dimensions Dimensions are approximate and subject to change. • Each unit (standard) comes with one (1) halogen lamp (6V-6W or 12V-8W) • Surface mount, semi-recessed units and fully recessed kits are constructed of an off-white, impact resistant, flame retardant, polymeric material. Fully-recessed, “FRM” option units have an all-metal back box • Available with sealed, maintenance-free Nickel-Cadmium, Long Life Lead, or Lead-Calcium batteries • PulsePlus Charger circuitry offers 120/277VAC 60Hz., 0.3/0.15A (other inputs available), fused output circuit(s), temperature compensated charger, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • All models are supplied with a specular reflector and are designed to mount directly to a standard octagonal electric box • UL Listed. Complies with NEC, Life Safety Code and OSHA. Approved use in the Commonwealth of Pennsylvania • 3-year full warranty, excluding lamps, pilot lights and fuses Junction Box by others Ceiling 4” Semi-Recessed Plastic Square Requires Optional Mounting Kit 6 volt unit furnished with 6 watt Halogen lamp(s). 12 volt unit furnished with 8 watt Halogen lamp(s). Junction Box by others Ceiling 4” 10” Sq. UNIT EQUIPMENT – NO REMOTE CAPABILITY Fully-Recessed Plastic Square Requires Optional Mounting Kit Watts to 87-1/2% of rated battery voltage* Model Number 1-1/2 hrs 2 hrs 3 hrs 4 hrs Long Life Lead 6 PSE9 9 7 – – Lead-Calcium 6 PSM9 9 6 – – Metal Back Box Long Life Lead 6 PSC18 18 12 9 6 6 PSC18-2 18 12 9 6 6 PSC25 25 18 12 9 6 PSC25-2 25 18 12 9 12 12PSC36 36 21 15 12 12 12PSC36-2 36 21 15 12 6 PSE18 18 11 8 6 6 PSE18-2 18 11 8 6 Ceiling 3-1/4” 10-5/8” Sq. Fully-Recessed Metal Square Optional UNIT EQUIPMENT – WITH REMOTE CAPABILITY Nickel-Cadmium Ceiling 9” Sq. Fully-Recessed Option D.C. Voltage Junction Box by others 2-1/4” Unit Rating Sealed MaintenanceFree Battery Types Semi-Recessed Option 9” Sq. Surface Mount Plastic Square Accessories (order as a separate item) DESCRIPTION * National Electrical Code Specification -2 indicates two lamp version SUFFIX Semi-Recessed Kit (converts a surface mount unit to semi-recessed) PS-SRKIT* Fully-Recessed Kit (converts a surface mount unit to fully-recessed) PS-FRKIT* Wire Guard (Surface or Semi-Recessed) WG1-E Wire Guard (Fully-Recessed) WG11-E * Bar hangers included. For standard units without options only order Model Number. Options are added to units by listing suffix at end of model # How to Order SERIES BATTERY TYPE/CAPACITY PS= 6V Series C18= 6V-18W Ni-Cd C25= 6V-25W Ni-Cd E9= 6V-9W Long Life Lead E18= 6V-18W Long Life Lead M9= 6V-9W Lead-Calcium 12PS= 12V Series C36= 12V-36W Ni-Cd # OF LAMPS Blank= One lamp -2= Two lamps LAMP TYPE Blank= 6V-6W or 12V-8W halogen bi-pin HB= 6V-8W halogen bi-pin HC= 6V-10W halogen bi-pin HD= 6V-12W halogen bi-pin HG= 12V-12W halogen bi-pin Note: See lamp data sheet in general information section for details Example: PSC18-2HA-AD-FRM 16 DIAGNOSTIC OPTION Blank= Standard unit -AD= Advanced Diagnostics (audible) -ADNA= Advanced Diagnostics (non-audible) OPTIONS Blank= No options -V= Voltmeter* -A= Ammeter -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -J= Polycarbonate lens -FRM= Fully-recessed all-metal unit * Voltmeter not available with -FRM fully recessed and PS-FR kit TYPE: CATALOG #: SPEC GRADE NOTES: RS Series 6 and 12 Volt Decorator Recessed Emergency Lighting Features Dimensions Dimensions are approximate and subject to change. Unit Rating EF-9 lamp heads: 6 or 12 volt 9 watt High Intensity Incandescent lamps. UNIT EQUIPMENT – NO REMOTE CAPABILITY Optional Features DESCRIPTION SUFFIX -NYC New York City (EF-18 12 Watt Lamps) ACCESSORIES Wire Guard (Units with EF-9, EF-10 or EF-18, EF-150 Heads) WG6-E Remote Test Switch (metal face plate) RTS Remote Test Switch (plastic face plate) RTS-1 EF9 EF18 Back Box ARCHITECTURAL • Each unit comes with two (2) 6 or 12V-9W high-intensity incandescent EF-9 lamp heads (standard). EF-10, EF-18, EF-32 and EF-150 lamp heads are optional • Constructed of 20-gauge steel with an off-white baked enamel finish • Available with sealed, maintenance-free Nickel-Cadmium, Long Life Lead, or Lead-Calcium batteries • PulsePlus Charger circuitry offers 120/277V input 60 Hz., 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensated charger, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Fully-recessed assembly for ceiling or wall mount. Includes adjustable bar hangers for grid ceilings. Can be framed into studs/joists • UL924 Listed. Complies with NEC, Life Safety Code and OSHA Approved use in the Commonwealth of Pennsylvania and New York City • 3-year full warranty, excluding lamps and fuses Sealed MaintenanceFree Battery Types D.C. Voltage Ni-Cd 6 RSC18-2150 Long Life Lead 6 RSE18-2150 Lead-Calcium 6 RSM18-2150 Watts to 87-1/2% of rated battery voltage* Model Number 11⁄2 hrs 2 hrs 3 hrs RSC18-2 18 12 10 – RSC18-2 18 11 8 – RSM18-2 18 12 9 – EF-9 Lamp Heads EF-150 Deco 4 hrs UNIT EQUIPMENT – WITH REMOTE CAPABILITY NickelCadmium Long Life Lead LeadCalcium 6 RSC25-2150 RSC25-2 25 18 12 9 12 12RSC36-2150 12RSC36-2 36 21 15 12 12 12RSC50-2150 12RSC50-2 50 36 25 18 6 RSE27-2150 RSE27-2 27 19 14 10 6 RSE36-2150 RSE36-2 36 24 17 13 12 12RSE36-2150 12RSE36-2 36 24 17 13 6 RSM27-2150 RSM27-2 27 18 14 10 6 RSM36-2150 RSM36-2 36 25 20 14 12 12RSM36-2150 12RSM36-2 36 25 20 14 * National Electrical Code Specification How to Order COLOR SERIES/BATTERY TYPE WATTS HEADS LAMP TYPE Blank= Factory white B= Black enclosure RSC18= 6V-18W Ni-Cd RSC25= 6V-25W Ni-Cd RSE18= 6V-18W Long Life Lead RSE27= 6V-27W Long Life Lead RSE36= 6V-36W Long Life Lead RSM18= 6V-18W Lead-Acid RSM27= 6V-27W Lead-Acid RSM36= 6V-36W Lead-Acid 12RSC36= 12V-36W Ni-Cd 12RSC50= 12V-50W Ni-Cd 12RSE36= 12V-36W Long Life Lead 12RSM36= 12V-36W Lead-Acid -0= No head -1= One head -2= Two heads Blank= EF9 Mini PAR 18 style 10= EF10 Mini plastic MR16 18= EF18 (PAR 36 plastic) 28= EF28 (PAR 36 metal) 150= EF150 Deco heads MR16 Blank= 6V-9W or 12V-9W Inc. wedge base LA= 6V-4W, MR16 LED* LG= 12V-4W, MR16 LED* LI= 12V-5W, MR16 LED* LJ= 12V-6W, MR16 LED* H_= Halogen bi-pin I_= Inc. DC-bayonet U_= Inc. sld-beam** X_= Halogen sld-beam** Z_= Inc. wedge M_= Halogen MR16* NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 * Available with EF10 and EF150 lamp heads only ** Available with the EF18 lamp head only Example: BRSC18-210LA-AD 17 OPTIONS Blank= No options -AD= Advanced Diagnostics (audible) -ADNA= Advanced Diagnostics (non-audible) -V= Voltmeter -A= Ammeter -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) TYPE: CATALOG #: SPEC GRADE NOTES: TS Series 6, 12 and 24 Volt T-Bar Units ARCHITECTURAL Features Dimensions Dimensions are approximate and subject to change. • Each unit comes with two (2) off-white EF-18 lamp heads (standard) with one 9W wedge-based lamp per head. Provisions for mounting three heads are included • Constructed of 20-gauge steel with an off-white baked enamel finish • Available with sealed, maintenance-free Nickel-Cadmium, Long Life Lead, or Lead-Calcium batteries • PulsePlus Charger circuitry offers 120/277V input 60Hz., 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensated charger, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Fully-recessed housing for unobtrusive use in T-Bar ceilings. A removable cover on the back box allows for ease of installation and full access to the battery and charger • UL Listed. Complies with NEC, Life Safety Code and OSHA. Approved use in the Commonwealth of Pennsylvania and New York City • 3-year full warranty, excluding lamps, pilot lights and fuses 23-3/4” 11-1/2” 13-1/8” 7-1/4” Unit Rating Furnished standard with two 9 watt High Intensity Incandescent lamps. UNIT EQUIPMENT – NO REMOTE CAPABILITY Sealed MaintenanceFree Battery Types D.C. Voltage Model Number Watts to 87-1/2% of rated battery voltage* 1 hrs 1⁄2 2 hrs 3 hrs 4 hrs Cabinet Size EF18 Nickel-Cadmium 6 TSC18-2 18 12 9 6 S Long Life Lead 6 TSE18-2 18 11 8 6 S Cabinet Size Lead-Calcium 6 TSM18-2 18 12 10 7 S S L 9 S UNIT EQUIPMENT – WITH REMOTE CAPABILITY 6 Nickel-Cadmium Long Life Lead Lead-Calcium TSC25-2 25 18 12 EF9 Dimensions a 3-1/4” 5-5/8” b 4-5/8” 7-1/8” Accessories (order as a separate item) 12 12TSC36-2 36 21 15 12 S 12 12TSC50-2 50 36 25 18 S 24 24TSC100-2** 100 73 50 37 S** Remote Test Switch (metal face plate) RTS Remote Test Switch (plastic face plate) RTS-1 6 TSE27-2 27 19 14 10 S 6 TSE36-2 36 24 17 13 S S 6 TSE54-2 50 32 22 16 6 TSE110-2 110 74 57 43 L 12 12TSE36-2 36 24 17 13 S 12 12TSE54-2 54 37 28 21 S 12 12TSE72-2 72 62 43 33 L 12 12TSE110-2 110 74 57 43 L 24 24TSE72-2 72 48 34 26 L 24 24TSE110-2 110 74 57 43 L 6 TSM27-2 27 18 14 10 S 6 TSM36-2 36 25 20 14 S 6 TSM54-2 54 37 28 21 S 6 TSM81-2 81 54 42 30 L 6 TSM110-2 110 72 56 40 L 12 12TSM36-2 36 25 20 14 S 12 12TSM54-2 54 37 28 21 S 12 12TSM110-2 110 72 56 40 L 24 24TSM110-2 110 72 56 40 L * National Electrical Code Specification ** AD & ADNA not available DESCRIPTION = New York City Approved 18 SUFFIX TYPE: CATALOG #: SPEC GRADE NOTES: TS Series 6, 12 and 24 Volt T-Bar Units How to Order SERIES/BATTERY TYPE/ CAPACITY SERIES TSC18= 6V-18W Ni-Cd TSC25= 6V-25W Ni-Cd TSE18= 6V-18W Long Life Lead TSE27= 6V-27W Long Life Lead TSE36= 6V-36W Long Life Lead TSE54= 6V-54W Long Life Lead TSE110= 6V-110W Long Life Lead -0= No head -1= One head -2= Two heads -3= Three heads HEAD STYLE Blank= EF18 (PAR 36 plastic) 28= EF28 (PAR 36 metal) 9= EF9 mini plastic 10= EF10 Mini plastic MR16 150= EF150 MR16 lamp heads TSM18= 6V-18W Lead-Acid TSM27= 6V-27W Lead-Acid TSM36= 6V-36W Lead-Acid TSM54= 6V-54W Lead-Acid TSM81= 6V-81W Lead-Acid TSM110= 6V-110W Lead-Acid LAMP TYPE/WATTAGE Blank= 6V-9W or 12V-9W Inc. wedge base LA= 6V-4W, MR16 LED* LG= 12V-4W, MR16 LED* LL= 24V-4W, MR16 LED* LI= 12V-5W, MR16 LED* LJ= 12V-6W, MR16 LED* H_= Halogen bi-pin I_= Inc. DC-bayonet U_= Inc. Sld-beam** X_= Halogen sld-beam** Z_= Inc. wedge M_= Halogen MR16* OPTIONS -AD= Advanced Diagnostics (audible)* -ADNA= Advanced Diagnostics (non-audible)* -V= Voltmeter -A= Ammeter -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -NEX= Nexus® wired (consult your sales representative) -NEXRF= Nexus® wireless (consult your sales representative) 12TSC36= 12V-36W Ni-Cd 12TSC50= 12V-50W Ni-Cd 12TSE36= 12V-36W Long Life Lead 12TSE54= 12V-54W Long Life Lead 12TSE72= 12V-72W Long Life Lead 12TSE110= 12V-110W Long Life Lead 12TSM36= 12V-36W Long Life Lead 12TSM54= 12V-54W Long Life Lead 12TSM110= 12V-110W Long Life Lead 24TSC100= 24V-100W Ni-Cd 24TSE72= 24V-72W Long Life Lead 24TSE110= 24V-110W Long Life Lead 24TSM110= 24V-110W Lead-Acid NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 * Available with EF10 and EF150 lamp heads only ** Available with the EF18 lamp head only Example: BTSC17-210L_-AD 19 * Minimum lamp load required: 20% of unit capacity Not available with 100W Ni-Cd 24V ARCHITECTURAL Blank= Factory white B= Black enclosure # OF HEADS TYPE: CATALOG #: SPEC GRADE NOTES: US EFR2™ Distinction Series Self-Powered Recessed Down Light ARCHITECTURAL Standard Features Dimensions Dimensions are approximate and subject to change. • One 6V-6W MR16 halogen lamp can be adjusted by rotating the gimbal through 359° in azimuth and or positioning the lamp through 90° in pitch • The recessed gimbal is constructed of durable, powder-coated, Die-Cast aluminum. A metal, fully-recessed back box houses the electronics, battery and wiring • Self-Powered. Sealed long-life Nickel-Cadmium battery for operation of at least 90 minutes as required by NFPA 101 Life Safety Code • Power requirements: 120V, 60Hz, 0.046A, 4.17W; 277V, 60Hz, 0.024A, 4.76W • Operation is completely automatic. A brownout sensitive transfer circuit automatically connects the emergency lamp upon either complete loss of normal AC power or when the AC voltage drops down to a point where normal AC lighting will not function. The unit also monitors DC battery voltage and disconnects the lamps before the battery can go into deep discharge (in conditions of extended power failures). When the AC power is restored the charger automatically returns the battery to full charge in 24 hours, and monitors the battery to maintain full charge • Includes bar hanger kit. Quick disconnect feature allows the contractor to easily install the trim on the housing • Easy to access for maintenance personnel • Evaluated to UL 924 standards 7-9/16” 6-7/8” 5” 14” 5” Unit Data EFR2 Series including back box The recessed gimbal is constructed of a durable, powder coated, Die-Cast aluminum and is furnished with an MR16 lamp source powered by a sealed Nickel-Cadmium battery. The unit will be furnished with a metal, fully recessed back box to house the electronics, battery and all associated wiring. Furnished standard with bar hanger kit. Charger The light source shall be adjusted by rotating the gimbal through 359° in azimuth and or positioning the lamp through 90° in pitch. Electrical power requirements: 120V, 60Hz, 0.046A, 4.17W 277V, 60Hz, 0.024A, 4.76W The light source will be 6 volts 6 watts MR16 halogen lamp. The emergency lighting fixture will provide illumination in the emergency mode directly from the internally mounted Nickel-Cadmium battery. The duration of operation provided by the Nickel-Cadmium battery will be no less than 90 minutes as required by NFPA 101 Life Safety Code. Transfer: Dust tight relay automatically and instantly energizes lamp load upon failure of AC supply. Battery protection circuit automatically shuts down lamp load when battery reaches 87-1/2% of its rated voltage. Charger is 100% solid state, includes auto-equalize, temperature compensation and is controlled by a 1% Zener reference. Accessories (order as a separate item) DESCRIPTION SUFFIX Remote Test Switch (metal face plate) RTS Remote Test Switch (plastic face plate) RTS-1 Replacement lamp number (6V-6W) 580.0074-E How to Order SERIES EFR2= Distinction COLOR WH= White BK= Black BN= Brushed nickel CH= Chrome PB= Polished brass STANDARD SP= Self-Powered Example: EFR2WHSP-U 20 MODEL -U= USA model TYPE: CATALOG #: SPEC GRADE NOTES: GS Series 6 Volt Recessed Down Light Standard Features Dimensions Dimensions are approximate and subject to change. • An adjustable gimbal directs the light from one (1) 6V wedge-base PAR 36 lamp head • The low-profile trim ring is molded in tough polycarbonate with a semi-gloss white finish to complement a variety of ceilings. The fully-recessed back box is constructed of 20-gauge steel • Available with sealed, maintenance-free Nickel-Cadmium, Long Life Lead, or Lead-Calcium batteries • PulsePlus Charger circuitry offers 120/277VAC 60 Hz., 0.3/0.15 Amp, fused output circuit(s), long life LED pilot indicator, temperature compensated, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Inconspicuously mounted and easily accessed. The test switch and LED pilot light are located on the side of the lamp ring on the standard unit • A slide-out chassis and two quick-connect plugs make installation and servicing easy. Adjustable bar hangers included • UL Listed. Complies with NEC, Life Safety Code and OSHA • 3-year full warranty, excluding lamps, pilot lights and fuses ARCHITECTURAL 14” to 24” 7” 10-1/4” 6-1/2” 7-3/4” Accessories (order as separate item) DESCRIPTION 8-1/2” SUFFIX Remote Test Switch (metal face plate) RTS Remote Test Switch (plastic face plate) RTS-1 Unit Rating The GSM10 unit is furnished with one 6V-10W wedge-base lamp. Other wattages available, see lamp data sheet for selection of PAR lamps. Sealed Maintenance-Free Battery Types D.C. Voltage Watts to 87-1/2% of rated battery voltage* Model Number 1 hrs 2 hrs 1⁄2 A.C. Voltage 3 hrs 4 hrs Lead-Calcium 6 GSM10-BH 10 8 – – Long Life Lead 6 GSE9-BH 8 – – – Nickel-Cadmium 6 Unit Dual Voltage 120VAC Current Maximum .3A UNIT EQUIPMENT – WITH REMOTE CAPABILITY GSC18-BH 18 12 9 – 277VAC * National Electrical Code Specification .15A = New York City Approved How to Order For standard units without options only order Series, Battery and Watts. Options are added to units by listing suffix at end of model number. NOTE: Includes standard lamp (570.0016) COLOR Blank= White B= Black* * Black not available on GSM10-BH SERIES GS= Series BATTERY TYPE M10= 10W Lead-Calcium E9= 9W Long Life Lead C18= Nickel-Cadmium LAMP OPTION Wedge Base 9W standard* * Only C18 has other lamps available. For a complete list of available lamp types, please refer to the lamp data on pages 146-147. Example: GSM10BH-NYC 21 MOUTING OPTION BH= Bar hanger (standard) MODEL -NYC=Approved model* * Includes 12 watt lamp and metal trim. TYPE: CATALOG #: ARCHITECTURAL SPEC GRADE NOTES: Prestige™ Edge-Lit Series Die-Cast Aluminum Edge-Lit Exit Sign Design upgrade: introducing new features Electrical 1. Easier installation: component-free back-box housing and canopy can be installed in advance, like a regular junction box. 2. 20 – 30% less power consumption: max. 1.4W (AC-only models) and max. 2.3W (Self-Powered) 3. Bi-color LED pilot light allows visual diagnostic without the need to open the unit (self-test and diagnostic option) 4. Listed by the Underwriting Laboratories UL Listed 5. Also available with white LEDs for custom-design legends: pictograms, special wording, etc. (Ask your sales representatives) Power requirements: 120 to 277VAC, 50/60Hz. AC-only signs use 1.4 watts max, Self-Powered signs use 2.3 watts max while recharging batteries Available Models Circular trim plate models shown. optional Angular trim plate available. Features • Designed to achieve superior visual clarity and performance with a red and green LED light source. • Clear acrylic panel provides optimum light transmission. Illumination is 100% in both AC and emergency mode. • Computer engraving is used to crisply define each letter and chevron. LED sensitive inks are formulated to provide a rich color in red or green. Choice of legend background includes clear (for single face), white or mirror (for single or double face signs). • Clean trim plate design eliminates visible fasteners. Choice of trim plates: circular or angular. Standard finish is brushed aluminum for the housing, trim plate, trim ring and canopy. • Self-Powered models contain a sealed maintenance-free Nickel-Cadmium battery that provides 90 minutes of emergency illumination. • Two-wire universal 120 through 277VAC, 50/60Hz for AC-only and Self-Powered models. AC-only signs consume maximum 1.4W. SelfPowered signs use 2.3W max while recharging batteries. Solid state transfer automatically and instantly supplies the LED lamps from the back-up battery upon failure of AC supply. Close tolerance electronic circuit activates emergency unit when utility power dips below nominal voltage for brownout protection. Current-limited and short-circuit-proof charger. Full battery recharge is made in compliance with UL924 specifications. Test switch incorporates a green LED AC pilot light. • Self-test and silent diagnostic is optional on all Self-Powered models. It is programmed to ensure product readiness and reliability by continuously monitoring every critical function of the unit. The unit is self-tested for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. When a fault is detected the pilot light will change color from green to red and blink following a particular code, identifying the cause: battery, charger circuitry, or LED lamps. • Modular design allows for several mounting configurations. A trim ring and two 27-inch bar hangers are used for recessed mounting on walls or ceilings. A canopy allows for surface mounting on ceilings or walls as backor end-mount. Face panels snap securely into trim plate on all mounting configurations. • UL listed to UL 924 Standard. • 5-year full warranty. Recessed Wall Mount Recessed Ceiling Mount Surface Ceiling Mount Surface End Mount Recessed Models Surface Wall Mount Surface Models Housing Canopy Trim Ring Trim Plate Exit Plate Accessories (order as a separate item) Power Consumption DESCRIPTION Model SUFFIX AC-only AC Specs 120 to 277VAC DC Specs Less than 1.4W White Pendant P*-WT Black Pendant P-*BK AC/DC-remote 120 to 277VAC Less than 1.4W 6 to 24VDC Less than 1.4W P*-GY Self-Powered 120 to 277VAC Less than 2.3W Ni-Cd battery Min. 90 minutes Self-Powered diagnostic 120 to 277VAC Less than 2.3W Ni-Cd battery Min. 90 minutes Gray Pendant * Custom pendant lengths and colors available, specify (12”, 24”, 36”, etc) 22 TYPE: CATALOG #: SPEC GRADE NOTES: Prestige™ Edge-Lit Series Die-Cast Aluminum Edge-Lit Exit Sign ARCHITECTURAL Standard Circular Trim Plate Optional Angular Trim Plate Dimensions Dimensions are approximate and subject to change. 2-7/8” 16-3/4” 12-1/8” 2-7/8” 8-5/8” 7-1/2” 12-3/8” 6-1/4” 4” 10-5/8” 12-1/4” 4-5/8” 2-1/2” 1-1/8” 2-1/2” 4-5/8” 4” 16” 3-1/4” 13” Mounting Configurations Arrow (Chevron) Designation All mounting configurations use the same basic components. Inserting a trim ring allows for recessed mounting on walls or ceilings. Applying a canopy allows for surface mounting on ceilings or walls as back or end mount. EXIT>EXIT > < EXIT Arrow Right & Left (RL) Double Arrow Represents each side of a double face panel. (D) *Wording and chevrons not to scale. For illustration purposes only. How to Order HOUSING COLOR Blank= Brushed aluminum W= White B= Black PB= Polished brass CH= Polished chrome BR= Bronze SERIES FACES LX= AC-only LXN= SelfPowered 1= Single face 2= Double face DESIGNATION LEGEND BACKGROUND COLOR COLOR N= New design R= Red G= Green C= Clear (single face only) W= White M= Mirror Example: WLXN2NRWR-A-D 23 ARROWS TRIM MOUNTING OPTIONS LEGEND SIZE Blank= No arrow L= Arrow left R= Arrow right RL= Right and left (double face) D= Double arrow UA= Universal filled installed arrows -A= Angular -C= Circular Blank= Universal mount S= Surface mount (canopy) Blank= No option -NEX= Nexus® Wired (consult your sales representative) -NEXRF= Nexus® Wireless (consult your sales representative) -FA= Fire alarm -D= Self-Test and diagnostic -DC= AC/DC remote 6-24 VDC -2CKT= Two circuit, AC only -FZ= Flasher & buzzer (Self-Powered only) -X= Back box shipped separately Blank= 6” EXIT legend -8= 8” EXIT legend (red only) -LP= Panel shipped separately TYPE: CATALOG #: SPEC GRADE NOTES: Prestige™ X40 Series Edge-Lit Recessed Ceiling-Mount Only Exit Sign ARCHITECTURAL Design upgrade: introducing new features Dimensions Dimensions are approximate and subject to change. 1. Easier installation: component-free back-box can be installed in advance, like a regular junction box 2. 20 – 30% less power consumption: max. 1.4W (AC-only) and max. 2.3W (Self-Powered) 3. Bi-color LED pilot light allows visual diagnostic without the need to open the unit (self-test and diagnostic option) 4. Listed by the Underwriting Laboratories UL Listed 5. Also available with white LEDs for custom-design legends: pictograms, special wording, etc. (Ask your sales representative) 15” 3-1/4” 3-7/8” 7-1/2” 7-5/8” Features • Designed to achieve superior visual clarity and performance with an LED light source. High brightness red or green LEDs transmit light directly into both ends of a unique U-shaped panel. LED sensitive inks are formulated to provide a rich color in red or green • Clear acrylic panel provides optimum light transmission. Illumination is 100% in both AC and emergency mode • Clear acrylic panel is silkscreened and computer engraved. Computer engraving is used to crisply define each letter and chevron. LED sensitive inks are formulated to provide a rich color in red or green. Choice of legend background: clear (for single face), white or mirror (for single or double face signs) • Rugged cast brushed aluminum trim plate (optional colors available). • Low energy consumption LED lamps consume less than 2.3W per sign, single or double face, AC-only or Self-Powered • Available with sealed maintenance-free Nickel-Cadmium batteries. • Fully automatic charger circuitry offers two-wire universal 120 to 277VAC input, temperature compensated charger, solid state transfer, low voltage battery disconnect, and brownout protection • Self-test and silent diagnostics are optional on all Self-Powered models. Diagnostics are programmed to ensure product readiness and reliability by continuously monitoring every critical function of the unit. The unit is self-tested for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. When a fault is detected the pilot light will change color from green to red and flash following a particular code, identifying the cause: battery, charger circuitry, or LED lamps • Designed to fit integrally with a 20 gauge steel back box. Each unit includes a bar hanger kit • UL listed to UL 924 Standard • Prestige LED Series signs are unaffected by the vibrations, ambient temperature swings and typical power surges detrimental to standard exit light sources • 5-year full warranty 12-15/16” 3-15/16” Power Consumption Chart Model AC Specs DC Specs AC-only 120 to 277VAC Less than 1.4W AC/DC-remote 120 to 277VAC Less than 1.4W 6 to 24VDC Less than 1.4W Self-Powered 120 to 277VAC Less than 2.3W Ni-Cd battery Min. 90 minutes Self-Powered diagnostic 120 to 277VAC Less than 2.3W Ni-Cd battery Min. 90 minutes Accessories (order as a separate item) DESCRIPTION Contact your sales representative Special wording DESCRIPTION Two 27-inch adjustable bar hangers* TBH * Bar hangers supplied with unit, order as replacement only Arrow (Chevron) Designation EXIT> EXIT > < EXIT Arrow Right & Left (RL) Double Arrow Represents each side of a double face panel. (D) *Wording and chevrons not to scale. For illustration purposes only. How to Order HOUSING SERIES FACES Blank= Brushed aluminum W= White B= Black PB= Polished brass CH= Polished chrome BR= Bronze LX= AC LSNX= Self-Powered 40= Less panel 42= Single face 43= Double face DESIGNATION N= New design LEGEND COLOR R= Red G= Green BACKGROUND COLOR C= Clear (single face only) W= White M= Mirror ARROWS Blank= No arrow L= Arrow left R= Arrow right RL = Right & left (double face) D= Double arrow UA= Universal field installed arrows OPTIONS Blank= No option -AD= Advanced Diagnostics (audible) -FA= Fire Alarm -DC= AC/DC remote 6-24 VDC -2CKT= Two circuit, AC only -FZ= Flasher & buzzer (Self-Powered only) -NEX= Nexus® Wired* -NEXRF= Nexus® Wireless* * Consult your sales representative. Example: WLSNX42NRWR-AD 24 LEGEND SIZE Blank= 6” EXIT legend -8= 8” EXIT legend (red only) -L= 6” EXIT low profile panel -LP= Panel shipped separately -X= Back box shipped separately TYPE: CATALOG #: SPEC GRADE NOTES: US Prestige™ DX Series Die-Cast Exit Sign Features Dimensions Dimensions are approximate and subject to change. 6-1/4” a b 4-5/8” 7/8” 1-3/4” Accessories (order as a separate item) DESCRIPTION PD**W Black Pendant PD**B Pendant Mount Gray PD**GY Wire Guard (Wall Mount) (6 in.) WG12-E Wire Guard (Ceiling Mount) (6 in.) WG5-E Wire Guard (End Mount) (6 in.) WG5-E 6” 8” Power Consumption Model 6” * Specify Pendant Length (12”, 24”, 36”, etc) How to Order Blank= Black/brushed aluminum WW= White/white WA= White/brushed aluminum BZ= Bronze/bronze BB= Black/black AA= All brushed aluminum SERIES # OF FACE DXN= Self-Powered unit DX= AC/DC* 1= Single face 2= Double face LEGEND COLOR R= Red G= Green * Not available with Nexus® Wireless option – – AC/DC-remote 120 to 277VAC 6 to 48VDC Less than 1.5W Self-Powered 120 to 277VAC Ni-Cd battery AC Specs 120 to 277VAC – – AC/DC 120 to 277VAC 6 to 24VDC 1.6W Self-Powered 120 to 277VAC Ni-Cd battery Min. 90 minutes DIAGNOSTIC OPTIONS Blank= Standard NEX= NEXUS® wired (consult your sales representative) OPTIONS Blank= Standard DL= Damp Location FA= Fire alarm activated flasher FZ= Flasher buzzer (Self-Powered only)* VR= Vandal Resistant screws VR1= Polycarbonate shield with tamper proof screws 2CKT= 2 Circuit (120/120 or 277/277, AC only)* *Not available with Nexus® option Example: DXN1R-N 25 Min. 90 minutes DC Specs AC-only Blank= 6” letters 8= 8” letters * Open face required for special wording DC Specs 120 to 277VAC LETTERS Open face RW= Red on white GW= Green on white AC Specs AC-only Model 8” COLOR FRAME/ FACEPLATE Dimensions a b 8-7/8” 13-1/16” 10-1/2” 15-1/4” Letters SUFFIX White Pendant ARCHITECTURAL • Red and green LED light source • Constructed of Die-Cast aluminum. Finished with a deep brushed face and black body. Optional finishes available. Self Contained. Batteries and circuitry are located inside the exit housing • Available with sealed maintenance-free Nickel-Cadmium batteries that provide 90 minutes of emergency operation. Batteries recharge per UL924 requirements • Fully automatic charger is solid state. All models are Universal 2-wire, 120 through 277VAC, 50/60Hz • Continuous self-diagnostic monitoring. Self-testing per Life Safety Code requirements. Diagnostic / Self Test circuitry is standard on all Self-Powered models. This circuitry is programmed to ensure the exit’s readiness and reliability by continuously monitoring every critical function of the unit. If a problem occurs, a single “service required” indicator illuminates immediately. A detailed diagnostic display that will further indicate the nature of the fault is located on the inside of the exit sign, out of sight from the general public. The self test will test the unit for a minimum of 30 seconds every 30 days, 30 minutes every 60 days and 90 minutes annually • Can be wall, end or ceiling mounted • Evaluated to UL 924 Standard. AC-Only Signs are Listed for use in damp locations • Unaffected by the vibrations, ambient temperature swings and typical power surges detrimental to standard exit light sources • Universal directional chevron knockouts are completely concealed and easily removed from the face plate • 5-year full warranty VERSION -N= New design* * Not required for 8” letters TYPE: CATALOG #: SPEC GRADE NOTES: Prestige™ Floor Proximity Series Master with Remote Exit Sign ARCHITECTURAL Standard Features Dimensions Dimensions are approximate and subject to change. • Low energy consumption LED light source (see Power Consumption chart). Red and green LEDs provide excellent visual performance, high reliability and low maintenance costs • Self-Powered Master Units have self-contained batteries and circuitry inside the housing • Available with sealed maintenance-free Nickel-Cadmium batteries for superior performance and long life. Provides 90 minutes of emergency operation and remote power for Proximity EXIT sign • Remote Floor Proximity EXIT signs have power and diagnostics supplied from the DX/DXN Series Master Units only • Stand alone AC-Only and Self-Powered Units: 120/277VAC dual voltage • Master EXIT sign comes standard with the Self-Test/Diagnostic Feature. Its circuitry also monitors and supplies diagnostics to the Remote Floor Proximity EXIT sign. The self-test/diagnostic feature continuously monitors the charger assembly, battery and LED assembly current. If a fault is indicated, the “external service” required indicator will illuminate. The internal fault indicators will then indicate the nature of the fault. The self-test diagnostic will self test for minimum 30 seconds every 30 days, 30 minutes every 60 days and 90 minutes annually. Meets NFPA 101 Life Safety Code requirements for periodic testing • Available for surface or recessed mounting at floor level • Evaluated to UL 924 Standard for floor proximity applications • 5-year full warranty. Each unit is fully tested Self-Powered/AC-Only Master DXN1G-M-N DX1G-M-N 8-7/8” 13-1/4” 1-5/8” Floor Proximity Slave Surface Mount LLGS LLRS 14-1/8” 1-1/8” Accessories (order as a separate item) DESCRIPTION Wire Guard (for floor proximity recessed) SUFFIX Red or Green LED Light Source WG11-E Features (optional) Polycarbonate Lens DESCRIPTION Vandal-Resistant shield and screws SUFFIX 8-5/8” Mounting Center 4 Vandal-resistant screws VR1 Floor Proximity Slave Recessed Mount LLGR LLRR 15-1/2” 1-1/8” 13-7/8” 4 Vandal-resistant screws Red or Green LED Light Source 9-3/4” Polycarbonate Lens Mounting Center 26 8-1/16” TYPE: CATALOG #: SPEC GRADE NOTES: US Prestige™ Floor Proximity Series How to Order for a Typical Application Self-Powered Master with Floor Proximity Unit Self-Powered Master Example Model #: DXN1G-M-N EXIT 120/277 Volt Input 2 Circuit AC-Only Master Example Model #: DX1G-M-2CKT-N EXIT Low Voltage Wire EXIT Low Voltage Wire Floor Proximity Surface or Recessed EXIT Example Model #: LLGS Example Model #: LLGS How to Order AC-Only Master (Unit for above door) How to Order Self-Powered Master (Unit for above door) COLOR OPTION PREFIX SERIES Blank= Brushed alum. face, black body WW= All white BB= All black DXN FACES STENCIL FACE LAMP COLOR 1= Single R= Red face G= Green open 2= Double face* RW= Red/white face GW= Green/white -M COLOR OPTION PREFIX STANDARD SERIES DESIGNATOR MASTER UNIT Blank= Brushed alum. face, black body WW= All white BB= All black -N SERIES FACES STENCIL FACE MASTER CIRCUIT UNIT -M 1= Single R= Red face G= G reen open 2= Double face* RW= Red/white face GW= Green/white DX Example: DXN1G-M-N Example: DX1G-M-2CKT-N Floor Proximity Unit (Unit on side of door) Floor Proximity Unit (Unit on side of door) COLOR OPTION PREFIX SERIES Blank= Brushed alum. face, black body W= All white B= All black LL STENCIL FACE LAMP COLOR R= Red G= Green RW= Red/white GW= Green/white Floor Proximity Surface or Recessed MOUNTING R= Recessed S= Surface COLOR OPTION PREFIX OPTION Blank= Brushed alum. face, black body W= All white B= All black -VR1= Vandalresistant screws/ polycarbonate shield SERIES LL STENCIL FACE LAMP COLOR R= Red G= Green -2CKT MOUNTING R= Recessed S= Surface -VR1= Vandalresistant screws/ polycarbonate shield * Open face required for special wording (please contact your sales representative) * Open face required for special wording (please contact your sales representative) Power Consumption Chart Color Red Green Model AC Specs DC Specs AC-only 120/277VAC 1.3W – – AC-2 circuit 120/277 and 277/277VAC 2.6W – – Self-Powered 120/277VAC 3.8W Ni-Cd battery Min. 90 minutes AC-only 120/277VAC 1W – – AC-2 circuit 120/277 and 277/277 VAC 3.3W – – Self-Powered 120/277VAC 5W Ni-Cd battery Min. 90 minutes 27 -N OPTION Example: LL-GS-VR1 Example: LLGS-VR1 STANDARD SERIES DESIGNATOR ARCHITECTURAL 120/277 Volt Input AC-Only Master with Floor Proximity Unit 2 Circuit Application SPEC GRADE SPEC GRADE COMMERCIAL Table of Contents 30 X10 LED Series 45 Premier™ Combo Series 31 Prestige™ Recessed Economizer Series 46 Premier™ Exit Series 32 Prestige™ Economizer Series 47 Provider™ PRO-2N/ PRO-3N Series 33 Preceptor™ Die-Cast Series 48 EC-2/ECX-2 Series 34 Preceptor™ Recessed Series 49 ECC & ECM Series 35 Preceptor™ Remote Capacity Series 50 JC Series 36 Special Wording Configuration 51 JA Series 37 JS Series 38-39 LSE Series 40 LC Series 41 LS Series 42-43 24 LS & 24 LC Series 44 29 COMMERCIAL Premier™ Battery Series TYPE: CATALOG #: SPEC GRADE NOTES: Premier™ Series Thermoplastic Housing 6V up to 60W & 12V up to 72W Capacities Emergency Light COMMERCIAL Features Dimensions Dimensions are approximate and subject to change. • Simple, compact and contemporary design • Wall-mount or ceiling-mount installation (optional) • Two-piece housing of injection-molded thermoplastic • MR16 halogen or LED lamps, shielded by clear polycarbonate covers • Sealed, maintenance-free, Lead-Calcium or Nickel-Cadmium batteries • Dual voltage input: 120/277VAC. • Total load capacity up to 72W • UL924 Listed • Advanced Diagnostic-Audible (optional) • Certified for Damp Locations (optional) • NEXUS® interface (optional) • 5-year full warranty (excluding lamps and fuses) 12-1/4” 10-5/8” Wire Guards WG1-E 3-7/8” 37⁄8” Wall or flat ceiling mount Flat Ceiling Mount Power Consumption and Unit Rating Model Watts to 87-1/2% of rated battery voltage* AC Specs 1-1/2 hrs 18M 6V 30M 6V 40M 6V 60M 2 hrs 3 hrs 4 hrs 18 14 9 - 30 20 15 10 40 30 20 15 6/12V 60 40 30 20 72M 12V 72 54 36 27 20NC 6V 20 15 10 8 40NC 12V 40 30 20 15 50NC 12V 50 36 24 18 120/277VAC 120/277VAC * National Electrical Code Specification How to Order HOUSING COLOR Blank= White B= Black SERIES/CAPACITY PR18M= 6V-18W Lead-Calcium PR30M= 6V-30W Lead-Calcium PR60M= 6V-60W Lead-Calcium 12PR40M= 12V-40W Lead-Calcium 12PR60M= 12V-60W Lead-Calcium 12PR72M= 12V-72W Lead-Calcium PR20NC= 6V-20W Ni-Cd 12PR40NC= 12V-40W Ni-Cd 12PR50NC= 12V-50W Ni-Cd # OF LAMPS Blank= No head 2= 2 heads LAMP TYPE/WATTAGE LA= 6V-4W, MR16 LED LG= 12V-4W, MR16 LED LI= 12V-5W, MR16 LED LJ= 12V-6W, MR16 LED MI= 6V-6W MR16 MJ= 6V-10W MR16 MO= 12V-10W MR16 MK= 12V-12W MR16 MG=12V-20W MR16* * Not available with Damp Location Example: PR18M2MI 30 UNIT TYPE Blank= Standard -D= Advanced Diagnostics (non-audible)* -DA= Advanced Diagnostics (audible) -NEX= Nexus® Wired (consult your sales representative) -NEXRF= NEXUS® wireless (consult your sales representative) * Minimum lamp load required: 20% of unit capacity OPTIONS Blank= No option -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -CM= Ceiling mount -DL= Damp Location -PM= Pendant mount TYPE: CATALOG #: SPEC GRADE NOTES: Premier™ Series Combo Thermoplastic Combination Unit Features Dimensions Dimensions are approximate and subject to change. • Indirect refractive technology provides bright, even illumination • Choice of MR16 Halogen Lamps, shielded by a clear polycarbonate cover Optional MR16 LED lamps with a life expectancy of 50,000+ hours • Exit sign long-life LED light source for low maintenance costs and superior illumination • Durable injection-molded thermoplastic housing with push-to-snap design. Optional vandal-resistant shield with tamper-proof screws • Available with sealed, maintenance-free, Lead-Calcium or Nickel-Metal Hydride batteries • Dual voltage input: 120/277 VAC. Optional advanced diagnostic circuitry, flasher/buzzer, fire alarm activated flasher • Remote load capacity up to 50 watts when supplied with no heads • Available in single or double face configurations both with means for ceiling mounting. Easy-to-install canopy and field-selectable snap-in/out chevrons for quick and easy installation • UL924 Listed • 5-year full warranty (excluding lamps and fuses) 4-7/8” WG2-E Pendant White 081439-E Pendant Black 081439-E Model Watts to 87-1/2% of rated battery voltage* AC Specs 1-1/2 hrs 2 hrs 3 hrs Exit Sign Module * Specify pendant length REPLACEMENT BATTERIES 3-3/8” Power Consumption and Unit Rating SUFFIX Wire Guard (Wall mount) 11-1/4” 17” Accessories (order as a separate item) DESCRIPTION COMMERCIAL 12-3/8” REPLACEMENT LAMPS Battery Type 120/277VAC Less than 2W – – – 4 hrs – 612M Lead-Calcium 120/277VAC 0.11 / 0.05 A 12 8 – – 612H NiMH 0.11 / 0.05 A 12 9 – – 120/277VAC 624M Lead-Calcium 120/277VAC 0.11 / 0.05 A 24 16 12 9 1224M Lead-Calcium 120/277VAC 0.22 / 0.08 A 24 16 12 9 860.0004-E Lead-Calcium 580.0074-E 6V-6W, MR16 1224H NiMH 120/277VAC 0.22 / 0.08 A 24 18 12 9 022318-E NiMH 6V-12W 580.0079-E 6V-10W, MR16 1240H NiMH 120/277VAC 0.22 / 0.08 A 40 30 20 15 022319-E NiMH 12V-24W 580.0097-E 6V-4W, MR16 LED 1250H NiMH 120/277VAC 0.22 / 0.08 A 50 36 24 18 022320-E NiMH 12V-40W, 50W 580.0099-E 12V-10W, MR16 – 580.0080-E 12V-12W, MR16 – 580.0075-E 12V-20W, MR16 LED – 580.0093-E 12V-4W, MR16 LED – 580.0104-E 12V-5W, MR16 LED – 580.0106-E 12V-6W, MR16 LED *National Electrical Code Specification CONVERT SINGLE FACE TO DOUBLE FACE IN THE FIELD Red/White 005715-E Red/Black 005716-E Green/White 005717-E Green/Black 005718-E How to Order HOUSING COLOR SERIES W= White B= Black PR= Series VOLTAGE/CAPACITY/ BATTERY Lead-Calcium 612M= 6V-12W, Lead-Calcium 624M= 6V-24W, Lead-Calcium 1224M= 12V-24W, Lead-Calcium Nickel-Metal Hydride 612H= 6V-12W, NiMH, rated Damp Location 1224H= 12V-24W, NiMH, rated Damp Location 1240H= 12V-40W, NiMH, rated Damp Location 1250H= 12V-50W, NiMH, rated Damp Location FACES 1= single face (ceiling or wall mount) 2= double face (ceiling mount) 1N= single face no canopy (wall mount) 4= universal (2 faces, back plate and canopy) LEGEND COLOR G= Green legend R= Red legend # OF HEADS Blank= No heads 2= Two heads LAMP TYPE/ WATTAGE LA= 6V-4W, MR16 LED LG= 12V-4W, MR16 LED LI= 12V-5W, MR16 LED LJ= 12V-6W, MR16 LED MI= 6V-6W, MR16 MJ= 6V-10W, MR16 MO= 12V-10W, MR16 MK= 12V-12W, MR16 MG= 12V-20W, MR16 OPTIONS Blank= No option -AD= Advanced Diagnostics (audible) not available with 1250H* -ADNA= Advanced Diagnostics (non-audible) not available with 1250H* -BA= Brushed aluminum exit stencil -FZ= Flasher buzzer -FL= Flasher -FA= Fire alarm activated flasher -FBF= Flasher buzzer + fire alarm activated flasher -D3= Time Delay (15 minutes) -VR= Tamper-proof screws -VR1= Polycarbonate shield with tamper-proof screws -NEX= NEXUS® wired (consult your sales representative)* -NEXRF= NEXUS® wireless (consult your sales representative)* *Not available for 612M with “MI” lamp. Example: WPR612M1R2MI 31 TYPE: CATALOG #: SPEC GRADE NOTES: Premier™ Series LED Thermoplastic, universal-mount & snap-fit Exit Sign COMMERCIAL Features Dimensions Dimensions are approximate and subject to change. • Indirect reflective technology provides bright, even illumination • Long-life LED light source for low maintenance costs and superior illumination • Durable, injection-molded, thermoplastic housing. Optional vandal-resistant shield with tamper-proof screws • Energy efficient power consumption: less than 3.5 watts for Self-Powered version and less than 3W for AC only single or double face • Available with a sealed, maintenance-free Nickel-Cadmium battery • Dual voltage input: 120/277VAC. Optional Advanced Diagnostic circuitry, flasher/buzzer, and fire alarm-activated flasher • Standard Universal, supplied with two faceplates, back plate for wall mount and easy install canopy for end and ceiling mounting. Universal, fieldselectable snap in/out chevrons • UL924 Listed. All models are UL Listed for damp locations • 5-year full warranty 9” 8” 11-7/8” 2” 12-7/8” Wire Guards WALL CEILING WG1-E END WG5-E WG5-E Optional Self-Test/Self-Diagnostic Accessories (order as a separate item) Continuous self-diagnostic monitoring. Self-testing per Life Safety Code requirements. This circuitry is programmed to ensure the exit sign’s readiness and reliability by continuously monitoring every critical function of the unit. If a problem occurs, a single “service required” indicator illuminates immediately. A detailed diagnostic display that will further indicate the nature of the fault is located on the inside of the exit sign, out of sight from the general public. The self-test will test the unit a minimum of 30 seconds every 30 days, 30 minutes every 60 days and 90 minutes annually. SUFFIX DESCRIPTION Pendant White PRE-P-WH* Pendant Black PRE-P-BK* Wire Guard (wall mount) WG1-E Wire Guard (ceiling mount and end mount) WG5-E * Specify pendant length Power Consumption Each unit is furnished with one HIT lamp per head. AC SPECS MODEL DC SPECS AC-Only 120/277VAC, 60Hz Less than 2.5W – – AC / DC-remote 120/277VAC, 60Hz Less than 2W 6 to 48VDC Less than 1.5W Self-Powered 120/277VAC, 60Hz Less than 3.3W Ni-Cd battery Min. 90 minutes Self-Powered with Diagnostic 120/277VAC, 60Hz Less than 2.8W Ni-Cd battery Min. 90 minutes How to Order HOUSING COLOR W= White B= Black SERIES PREM= LED plastic EXIT UNIT TYPE COLOR Standard models AC= AC only (120/277V) U= 120/277VAC & 6 to 48VDC SNX= Self-Powered Ni-Cd Optional models 2C1= Dual AC circuit (2x120V) 2C2= Dual AC circuit (2x277V) DN= Self-Powered advanced diagnostic circuitry NEX= NEXUS® wired (consult your sales representative) NEXRF= NEXUS® wireless (consult your sales representative) R= Red universal R1= Red single face* R2= Red double face* G= Green universal G1= Green single face* G2= Green double face* Open face RW= Red on white GW= Green on white (Open face required with special wording legends) * Available with VR & VR2 options only Example: WPREMACR 32 OPTIONS Blank= No option BA= Brushed aluminum exit stencil FZ= Flasher buzzer (DN model only) FL= Flasher (DN model only) FA= Fire alarm activated flasher (AC, U, 2C1, 2C2 and DN models only) FBF= Flasher buzzer + fire alarm activated flasher (DN model only) VR= Vandal-resistant screws* VR1= Polycarbonate shield with tamper proof screws* * Please specify single or double face, red or green TYPE: CATALOG #: SPEC GRADE NOTES: Provider™ PRO-2N/PRO-3N Series 6 Volt Thermoplastic Housing Features Dimensions Dimensions are approximate and subject to change. 7 3 58" 114" 11-3/4” 5" 5-7/8” 5” COMMERCIAL • Completely self-contained, thermoplastic construction with a polycarbonate lens that protects the fully-adjustable self-locking heads • Available with sealed, maintenance-free Lead-Calcium batteries • Integrated circuitry offers 120/277VAC 60Hz standard operation, LED pilot light rocker type, test switch, temperature compensated, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Optional MR16 LED lamps with life expectancy 50,000+ hours •Optional advanced diagnostic circuitry monitors every critical function of the unit and provides an audible and visual indicator when a fault is detected (non-audible versions available) •Optional tamper-proof screws • Optional NEXUS® wired and NEXUS® wireless systems • Universal wall mounting pattern keyhole slots and a conduit knockout provide alternate mounting methods • Optional ceiling mount includes safety wire and pre-machined housing to receive a securement screw. • UL Listed. Complies with NEC, Life Safety Code and OSHA UL Listed for use in Damp Locations • 3-year full warranty, excluding lamps, pilot lights, and fuses. Fast and Easy Installation Snap-together design eliminates screws. Accessories (order as a separate item) SUFFIX DESCRIPTION Replacement lamps 570.0012-E Additional special bit for tamper-proof screws 690.0454-E REPLACEMENTS LAMPS Keyhole slot 570.0012-E HIT 6V-5.4W 580.0097-E MR16 LED 6V-4W Conduit knockout Power Consumption and Unit Rating Each unit are furnished with one HIT lamp per head. Provider’s AC quick-connect plug, battery lock out feature and snap-together design make installation fast and easy. With the AC quick-connect plug, contractors simply make the AC connection to the plug, mount the back plate and plug in the unit. PROVIDER™ BATTERY UNIT Sealed MaintenanceD.C. Voltage Free Battery Types Lead-Calcium Model Number Watts to 87-1/2% of rated battery voltage 1-1/2 hrs 2 hrs 3 hrs 4 hrs 6 PRO-2N 10.8 8.5 – – 6 PRO-3N 18 12 10 7 Universal mounting pattern AC-quick connect plug The battery lock out feature is an AC activated load switch that prevents the batteries from discharging until the unit is energized with AC power. This allows the contractor to install the Provider™ and connect the batteries in one convenient operation. Universal mounting pattern keyhole slots and a conduit knock out provide alternate mounting methods. *National Electrical Code Specification How to Order COLOR Blank= Off white B= Black SERIES PRO-2N= 6V-10.8W PRO-3N= 6V-18W LAMP TYPE -LA= 6V-4W, MR16 LED -ZP= mini tungesten, 6V-5.4W UNIT TYPE OPTIONS Blank= Standard Unit -AD= Advanced Diagnostics (audible) -ADNA= Advanced Diagnostics (non-audible) NEX= NEXUS® wired (consult your sales representative)* NEXRF= NEXUS® wireless (consult your sales representative)* V= Voltmeter * DL= Damp Location VR= Vandal-resistant screws C= Line Cord 120V - Supplied but not installed CM= Ceiling mount - Supplied with metal harness * Available with PRO-2N only. * Available with Standard unit type only. Example: BPRO-2N-LADL 33 SCAL TYPE: CATALOG #: SPEC GRADE NOTES: EC-2/ECX-2 Series Thermoplastic Housing 6V-12W Capacity Lead-Calcium Battery COMMERCIAL Features Dimensions Dimensions are approximate and subject to change. • Each self-contained unit comes with two (2) 5.4W high intensity incandescent lamps mounted in polished reflectors • Housing and heads are constructed of high-impact UL 94, 5VA flame classification, off-white thermoplastic. Resists denting, peeling, scratching and corrosion • Available with sealed, maintenance-free Lead-Calcium batteries • Integrated circuitry offers 120/277VAC 60 Hz, 0.3/0.15A standard operation, LED pilot light, automatic charging, instantaneous transfer, temperature compensated charger, low voltage battery disconnect, brownout protection, lock out (automatic battery connect) and reverse polarity protection • Universal mounting pattern, keyhole slots and conduit entry provide alternate mounting capability. The housing and back plate snap together for ease of installation • UL Listed. Complies with NEC, Life Safety Code and OSHA. UL Listed for use in damp locations • The EC-2 (12W max.) and ECX-2 (24W max.) Series have a 3-year full warranty, excluding lamps and fuses 16” 5” Flexibility in an emergency lighting unit • On the specification... Its contemporary design allows you to coordinate the aesthetics of emergency specifications with matching models – an emergency unit and a remote head. • On the job... Changes on the job are never a problem with the EC Series. Its modular design allows you to field upgrade the basic model to a master unit for powering matching remote lighting heads or AC/DC exit signs, including the new LED even illumination models. • On the shelf... The modular design of the EC Series gives you a contemporary family of decorative emergency lighting units, matching exit signs and remotes. Unit Rating Chart Furnished with two 5.4W high intensity incandescent lamps. UNIT EQUIPMENT Sealed MaintenanceFree Battery Types Model Number D.C. Voltage Watts to 90 minutes Remote Watts Lead-Calcium 6 EC-2 12 – Lead-Calcium 6 ECX-2 12 12 – Lead-Calcium 6 EC-2-AD 12 Lead-Calcium 6 ECX-2-AD 12 12 Nickel-Cadmium 6 EC-2-AD-N 12 – Nickel-Cadmium 6 ECX-2-AD-N 12 12 5” ECX - 12W Remote Capacity ECX-2 SERIES UNIT EQUIPMENT - WITH REMOTE CAPABILITY Watts to 87-1/2% of rated battery voltage* Sealed MaintenanceFree Battery Types 1-1/2 hrs 2 hrs 3 hrs 4 hrs Lead-Calcium 24 15 – – Nickel-Cadmium** 24 18 12 – * National Electrical Code Specification ** Only available with Diagnostics Matching EF23 Remote Heads LED Exit Signs How to Order COLOR SERIES B= Black housing EC= 6V-12W battery unit Blank= Off white ECX= 6V-24W battery unit HEADS/LAMPS OPTIONS Heads -2= Two heads (12W remote) -EG= Standard unit -AD= Advanced Diagnostics (audible) -ADNA= Advanced Diagnostics (non-audible) -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -DL= Damp Location listed (AD/ADNA units only) Lamps -2HA= 6V-6W bi-pin halogen -2HB= 6V-8W bi-pin halogen -2HC= 6V-10W bi-pin halogen -2HD= 6V-12W bi-pin halogen Example: BEC-2-EG-N 34 BATTERY OPTION Blank= Lead-Calcium -N= Nickel-Cadmium battery (AD/ADNA units only) TYPE: CATALOG #: SPEC GRADE NOTES: ECC and ECM Series 6 and 12V Steel Unit Features Dimensions Dimensions are approximate and subject to change. COMMERCIAL • Each unit comes with two (2) front-mounted EF-23 heads with 9W high intensity incandescent lamps (standard) • Constructed of 20-gauge steel with an off-white baked enamel finish • Available with sealed, maintenance-free Nickel-Cadmium or Lead-Calcium batteries • PulsePlus Charger circuitry offers 120/277VAC 60 Hz., 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Hinged front door • UL Listed. Complies with NEC, Life Safety Code and OSHA. Approved for use in the Commonwealth of Pennsylvania and New York City • 3-year full warranty, excluding lamps and fuses Accessories (order as a separate item) SUFFIX DESCRIPTION Mounting bracket (S cabinet only) BJ-EG Wire guard WG10-E Clear polycarbonate vandal-resistant shield VRS-BB** Clear NEMA 4X polycarbonate vandal-resistant shield VRSBB-4X** Cabinet Size Letters S L A 3-1/2” 4” B 6-1/8” 6-3/4” C 5-1/4” 6-1/4” D 11” 12-1/2” E 15-1/4” 16-1/2” ** S cabinet only, order on separate line. Unit Rating Sealed Maintenance-Free Battery Types Nickel-Cadmium Lead-Calcium D.C. Voltage Model Number Watts to 87-1/2% of rated battery voltage 1-1/2 hrs 2 hrs 3 hrs 4 hrs Cabinet Size 6 ECC18-2 18 12 – – S 6 ECC25-2 25 18 12 9 S 12 12ECC36-2 36 21 15 12 S 12 12ECC50-2 50 36 25 18 S 6 ECM18-2 18 12 10 7 S 6 ECM27-2 27 18 14 10 S 6 ECM36-2 36 24 20 14 S 6 ECM54-2 54 37 28 21 L 12 12ECM36-2 36 25 20 14 S 12 12ECM54-2 54 37 28 21 L How to Order COLOR Blank= Off white B= Black DC VOLTAGE Blank= 6V 12= 12V SERIES BATTERY TYPE WATTAGES EC C= Ni-Cd M= Lead-Calcium 18= 6V-18W Nickel or Lead-Calcium 25= 6V-25W Nickel-Cadmium 27= 6V-27W Lead-Calcium 36= 6V, 12V-36W Nickel or Lead-Calcium 50= 12V-50W Nickel-Cadmium 54= 6V, 12V-54W Lead-Calcium # OF HEADS -1= One head -2= Two heads LAMP TYPE Blank= 6V, 12V-9W wedge H_= Bi-pin halogen lamps Z_= High intensity incandescent wedge base NOTE:For a complete list of available lamp types, please refer to the lamp data on pages 146-147. For units without heads please see the JS series Example: B12ECC50-2HG 35 OPTIONS Blank= No options -AD= Advanced Diagnostics (audible) -ADNA= Advanced Diagnostics (non-audible) -NEX= Nexus® wired (consult your sales representative) -NEXRF= Nexus® wireless (consult your sales representative) -V= Voltmeter -A= Ammeter (S cabinet units. choose only one meter) -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -K= Lamp Disconnect Switch TYPE: CATALOG #: SPEC GRADE NOTES: JC Series Steel Housing 6V up to 40W & 12V up to 50W Capacities COMMERCIAL Features Dimensions Dimensions are approximate and subject to change. • Each unit comes with two (2) impact-resistant, flame retardant thermoplastic EF10 heads with 6W MR16 halogen or MR16 LED lamps (standard). Available with up to 20W(MW) high-output illumination heads • Compact steel cabinet with corrosion-resistant undercoating in white (standard). Black available as an option • Available with sealed, maintenance-free Nickel-Cadmium, or Lead-Calcium batteries • Power Requirements: 120/277VAC 60Hz, 0.3/0.15 Amp • Automatic, temperature-compensated solid state charger with a high capacity, automatic, dust-tight instantaneous transfer relay. Low voltage disconnect prevents over discharge of battery. Automatic brown out protection. Labor saving AC line latch prevents battery discharge during installation to a non-energized circuit. Fused output circuit. Optional Advanced Diagnostics comes with a micro controller based pulse-type charger • Rear keyhole mounting slots. Designed to mount directly to any standard 4” junction box • UL Listed • 3-year full warranty, excluding lamps and fuses 9-5/8” 5-1/2” 12-3/4” Unit Rating Furnished standard with two MR16 6V-6W. Sealed MaintenanceFree Battery Types Accessories (order as a separate item) D.C. Voltage SUFFIX DESCRIPTION Wire Guard (EF10, EF9 and EF150) WG1-E Wire Guard (EF18, EF23 and EF28) WG2-E Lead-Calcium Power Consumption Chart AC Input Maximum Input Current Input Power JC 120VAC 277VAC 0.20A 0.08A 24W 24W 12JC 120VAC 277VAC 0.24A 0.12A 30W 30W 12 6 Nickel-Cadmium COLOR SERIES DC VOLTAGE/CAPACITY JCM18= 6V-18W, Lead-Calcium JCM20= 6V-20W, Lead-Calcium JCM27= 6V-27W, Lead-Calcium JCM30= 6V-30W, Lead-Calcium JCM36= 6V-36W, Lead-Calcium JCM40= 6V-40W, Lead-Calcium 12JCM36= 12V-36W, Lead-Calcium 12JCM40= 12V-40W, Lead-Calcium JCC20= 6V-20W, Ni-Cd 12JCC36= 12V-36W, Ni-Cd 12JCC50= 12V-50W, Ni-Cd 12 Watts to 87-1/2% of rated battery voltage 1-1/2 hrs 18 2 hrs 3 hrs 4 hrs 12 – – JCM20 20 15 12 – JCM27 27 18 15 – JCM30 30 20 18 – JCM36 36 27 20 12 JCM40 40 30 24 15 12JCM36 36 27 20 12 12JCM40 40 30 24 15 JCC20 20 18 12 – 12JCC36 36 24 15 12 12JCC50 50 36 24 18 * National Electrical Code Specification How to Order Blank= Off white B= Black Model Number JCM 6 Model # 3-3/8” # OF HEADS -0= No head -2= Two heads HEAD STYLE 10= EF10 mini plastic MR16 150= EF150 lamp heads LAMP TYPE/WATTAGE LA= 6V-4W, MR16 LED LG= 12V-4W, MR16 LED LI= 12V-5W, MR16 LED LJ= 12V-6W, MR16 LED MH= 6V-5W, MR16 MI= 6V-6W, MR16 MJ= 6V-10W, MR16 MK= 12V-12W, MR16 MA= 12V-20W, MR16 MW= 12V-20W high output IR OPTIONS -AD= Advanced Diagnostics (audible)* -ADNA= Advanced Diagnostics (non-audible)* -NEX= NEXUS® wired (consult your sales representative)* -NEXRF= NEXUS® wireless (consult your sales representative)* -FM= Front mount heads * Not available with 6V - 40W unit (JCM40) Example: JCM18-210MI-AD 36 TYPE: CATALOG #: SPEC GRADE NOTES: JA Series Steel Housing with Protected Lighting Heads 6V up to 40W & 12V up to 50W Capacities Features Dimensions Dimensions are approximate and subject to change. • Each unit comes with two (2) emergency heads with adjustable swivels and long-life MR16 halogen or LED lamps 6V or 12V, available with up to 20W high output illumination • Steel cabinet with an anti-corrosion undercoating. The emergency heads are protected by a shock-absorbent, transparent polycarbonate cover. The cover is attached to the cabinet with two screws • Available with sealed, maintenance-free Nickel-Cadmium or Lead-Calcium batteries • Power requirements: 120/277 VAC 60Hz, 0.3/0.15 Amp • Solid State Charger is an automatic, temperature compensated type charger with high capacity, dust-tight instantaneous transfer relay and automatic brownout protection. Low voltage disconnect prevents over discharge of battery. Labor saving AC line latch prevents battery discharge during installation to a non-energized circuit. Fused output circuit. Optional Advanced Diagnostics comes with a micro controller based pulse type charger • The emergency heads are installed at the bottom of the unit, providing illumination in any downward direction and do not require a tool for adjusting or aiming • UL Listed • 3-year full warranty, excluding lamps and fuses. 12-3/4” Power Consumption Model # SUFFIX Wire Guard COMMERCIAL 9” Accessories (order as a separate item) DESCRIPTION 3-3/8” WG1-E Maximum AC Input Input Current Input Power JA 120VAC 277VAC 0.20A 0.08A 24W 24W 12JA 120VAC 277VAC 0.24A 0.12A 30W 30W Unit Rating Furnished standard with two MR16 6V-6W. Sealed Maintenance-Free Battery Types Voltage 6 Lead-Calcium 12 6 Nickel-Cadmium 12 Watts to 87-1⁄2% of rated battery voltage Model Number 1-1/2 hrs 2 hrs 3 hrs 4 hrs JAM20 20 – – – JAM30 30 20 – – JAM40 40 30 24 – 12JAM40 40 30 24 – JAC20 20 – – – 12JAC36 36 24 – – 12JAC50 50 36 24 – How to Order COLOR Blank= Off white B= Black SERIES DC VOLTAGE/CAPACITY JAM20= 6V-20W, Lead-Calcium JAM30= 6V-30W, Lead-Calcium JAM40= 6V-40W, Lead-Calcium 12JAM40= 12V-40W, Lead-Calcium JAC20= 6V-20W, Ni-Cd 12JAC36= 12V-36W, Ni-Cd 12JAC50= 12V-50W, Ni-Cd # OF HEADS -2= Two heads LAMP TYPE LA= 6V-4W, MR16 LED LG= 12V-4W, MR16 LED LI= 12V-5W, MR16 LED LJ= 12V-6W, MR16 LED MI= 6V-6W, MR16 MH= 6V-5W, MR16 MJ= 6V-10W, MR16 MK= 12V-12W, MR16 MA= 12V-20W, MR16 MW= 12V-20W IR high output OPTIONS -AD= Advanced Diagnostics (audible)* -ADNA= Advanced Diagnostics (non-audible)* -NEX= NEXUS® wired (consult your sales representative)* -NEXRF= NEXUS® wireless (consult your sales representative)* * Not available with 6V-40W unit (JAM40) Example: JAM20-2MI-AD 37 TYPE: CATALOG #: SPEC GRADE NOTES: JS Series Steel Housing 6V & 12V up to 54W Capacities COMMERCIAL Features Dimensions Dimensions are approximate and subject to change. • Each unit comes with two (2) EF18 heads with 9W high intensity incandescent lamps (standard) • Constructed of 20-gauge steel with an off-white baked enamel finish • Available with sealed, maintenance-free Nickel-Cadmium, Long Life Lead or Lead-Calcium batteries • PulsePlus Charger circuitry offers 120/277VAC 60 Hz., 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brown out protection and lock out (automatic battery connect) • Hinged cabinet door for easy access • UL Listed. Complies with NEC, Life Safety Code and OSHA. Approved for use in the Commonwealth of Pennsylvania and New York City • 3-year full warranty, excluding lamps and fuses Accessories (order as a separate item) EF18 EF9 SUFFIX DESCRIPTION Mounting Bracket (S cabinet only) BJ-E Wire Guard (S cabinet only) WG1-E Wire Guard (L cabinet only) WG2-E Wire Guard (front mounted heads) WG10-E Dimensions Cabinet Size **S cabinet only, order on separate line. a b c d 3-1/2” 5-1/4” S 11-3/8” // 9-3/4” 11” L 12-3/8” // 10-3/4” 12-3/4” 4” 6-1/4” Unit Rating Furnished standard with two 9 watt High Intensity Incandescent lamps. 6 JSC18-2 Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 3 hrs 4 hrs 18 12 – – 6 JSE9-1 9 7 – – S 6 JSE18-2 18 11 8 6 S 6 JSM9-1 9 6 – – S 6 JSM18-2* 18 12 10 Sealed Maintenance-Free Battery Types Nickel-Cadmium Long Life Lead Lead-Calcium D.C. Voltage Model Number Cabinet size S S UNIT EQUIPMENT - WITH REMOTE CAPABILITY Nickel-Cadmium Long Life Lead Lead-Calcium 6 JSC25-2 25 18 12 9 S 12 12JSC36-2 36 21 15 12 S 12 12JSC50-2 50 36 25 18 S 6 JSE27-2 27 16 12 10 S 6 JSE36-2 36 24 17 13 S 6 JSE54-2 54 37 28 21 L 12 12JSE36-2 36 24 17 13 S 12 12JSE54-2 54 37 28 21 L 6 JSM27-2 27 18 14 10 S 6 JSM36-2 36 25 20 14 S 6 JSM54-2 54 37 28 21 L 12 12JSM36-2 36 25 20 14 S 12 12JSM54-2 54 37 28 21 * National Electrical Code Specification L = New York City Approved 38 TYPE: CATALOG #: SPEC GRADE NOTES: JS Series A complete range of high performance and labor saving features How to Order COLOR Blank= Off white B= Black SERIES/CAPACITY JSC18= 6V-18W, Ni-Cd JSC25= 6V-25W, Ni-Cd JSE9= 6V-9W, Long Life Lead JSE18= 6V-18W, Long Life Lead JSE27= 6V-27W, Long Life Lead JSE36= 6V-36W, Long Life Lead JSE54= 6V-54W, Long Life Lead # OF LAMPS -0= No head -1= One head -2= Two heads HEAD STYLE Blank= (EF18 PAR 36 style ) 9= mini plastic 10= mini plastic MR16 28= EF28 Metal lamp heads 150= EF150 lamp heads JSM9= 6V-9W, Lead-Calcium JSM18= 6V-18W, Lead-Calcium JSM27= 6V-27W, Lead-Calcium JSM36= 6V-36W, Lead-Calcium JSM54= 6V-54W, Lead-Calcium 12JSC36= 12V-36W, Ni-Cd 12JSC50= 12V-50W, Ni-Cd LAMP TYPE/WATTAGE Blank_= 6V-9W and 12V9W incandescent wedge base H_= Halogen bi-pin I_= Incandescent DC-bayonet U_= Incandescent sealed-beam X_= Halogen sealed-beam Z_= Incandescent wedge M_= Halogen MR16* LA= 6V-4W, MR16 LED* LG= 12V-4W, MR16 LED* LI= 12V-5W, MR16 LED* LJ= 12V-6W, MR16 LED* OPTIONS -AD= Advanced Diagnostics (audible) -ADNA= Advanced Diagnostics (non-audible) -NEX= NEXUS® wired (consult your sales representative) -NEXRF= NEXUS® wireless (consult your sales representative) -V= Voltmeter (or ammeter)* -A= Ammeter (or voltmeter)* -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -K= Lamp disconnect switch -FM= Front mounted heads -CP= 120VAC cord & plug ** -E= Cord & plug (277VAC) ** 12JSE36= 12V-36W, Long Life Lead 12JSE54= 12V-54W, Long Life Lead 12JSM36= 12V-36W, Long Life Lead 12JSM54= 12V-54W, Long Life Lead * Available with EF10 and EF150 Lamp heads only. NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: JSC18-110LA 39 * Not available with AD or ADNA options. ** Standard cord is 3ft. COMMERCIAL Optional (FM suffix) Front Mounted Heads for low ceiling applications. TYPE: CATALOG #: SPEC GRADE NOTES: LSE Series 6 and 12 Volt Steel Enclosure COMMERCIAL Features Dimensions Dimensions are approximate and subject to change. • Each unit comes with two (2) EF-18 heads with 9 watt high intensity incandescent lamps (standard). One or three heads available as options • All-steel construction with an off-white baked enamel finish • Contains sealed, maintenance-free Long Life Lead batteries • Constructed of 20-gauge steel with an off-white baked enamel finish • PulsePlus Charger circuitry offers 120/277VAC, input 60 Hz., 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Removable front panel • UL Listed. Complies with NEC, Life Safety Code and OSHA. Approved for use in the Commonwealth of Pennsylvania and New York City • 3-year full warranty, excluding lamps and fuses EF18 A Optional Features SUFFIX DESCRIPTION Cord set - 120V -C* Special-voltage CP (TL 277V) -E* EF9 Dimensions Cabinet Size a b 14-5/8” // 13” 13-3/4” c d 3-1/8” 8-1/2” B 16-3/8” // 14-3/4” 16-1/8” 5-7/16” 10-1/4” C 18-3/8” // 16-3/4” 16-1/2” 7-1/4” 12-1/4” D 18-3/8” // 16-3/4” 27” 7-1/4” 12-1/4” Unit Rating * Standard cord is 3 ft. Furnished standard with two 9 watt High Intensity Incandescent lamps. Sealed D.C. Maintenance-Free Voltage Battery Types Accessories (order as a separate item) SUFFIX DESCRIPTION Mounting bracket (cabinet A) B1 Mounting bracket (cabinet B) B2 Mounting shelves (cabinet B) MP3-EG Mounting shelves (cabinet C) MP6-EG Mounting shelves (cabinet D) MP12 Wire Guard (cabinet A) WG2-E Wire Guard (cabinet B & cabinet C) WG3-E Wire Guard (cabinet D) WG4-E Long Life Lead 6 Model Number LSE18-2 Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 3 hrs 4 hrs 18 11 8 6 # of Cabinet Load size Fuses 1 A 1-1/2 hrs 2 hrs 4 hrs 8 hrs Long Life Lead 6 LSE27-2 27 19 10 5 1 A 6 LSE36-2 36 24 13 7 1 A 6 LSE54-2 54 36 20 11 1 A 6 LSE80-2 80 65 35 19 2 B 6 LSE110-2 110 74 43 21 2 B 12 12LSE36-2 36 24 13 7 1 A 12 12LSE54-2 54 37 21 10 2 A 12 12LSE72-2 72 48 26 14 2 B 12 12LSE110-2 110 74 43 21 2 B 12 12LSE320-2 320 210 120 60 2 D * National Electrical Code Specification = New York City Approved How to Order COLOR SERIES/CAPACITY Blank= Off white B= Black enclosure LSE18= 6V-18W Long Life Lead LSE27= 6V-27W Long Life Lead LSE36= 6V-36W Long Life Lead LSE54= 6V-54W Long Life Lead LSE80= 6V-80W Long Life Lead LSE110= 6V-110W Long Life Lead LSE160= 6V-160W Long Life Lead 12LSE36= 12V-36W Long Life Lead 12LSE54= 12V-54W Long Life Lead 12LSE72= 12V-72W Long Life Lead 12LSE110= 12V-110W Long Life Lead 12LSE160= 12V-160W Long Life Lead 12LSE320= 12V-320W Long Life Lead # OF LAMPS -0= No head -1= 1 head -2= 2 heads -3= 3 heads HEAD STYLE Blank= EF18 (PAR 36 plastic) 28= EF28 (PAR 36 metal) 9= EF9 (mini plastic) 10= EF10 (small plastic MR16) 150= EF150 (MR16 lamp heads) LAMP TYPE/WATTAGE Blank= 6V-9W and 12V-9W incandescent wedge base H_= Halogen bi-pin I_= Incandescent DC-bayonet U_= Incandescent sealed-beam** X_= Halogen sealed-beam** Z_= Incandescent wedge M_= Halogen MR16* LA= 6V-4W, MR16 LED* LG= 12V-4W, MR16 LED* LI= 12V-5W, MR16 LED* LJ= 12V-6W, MR16 LED* * Available with EF10 & 150 only ** Available with EF18 & EF28 only NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: BLSE18-128H-A 40 OPTIONS Blank= No options -AD= Advanced Diagnostics (audible)* -ADNA= Advanced Diagnostics (non-audible)* -NEX= NEXUS® Wired** -NEXRF= NEXUS® Wireless ** -V= Voltmeter (A cabinet units. Choose only one ) -A= Ammeter (A cabinet units. Choose only one) -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -FM= Front mounted lamp heads -CP= Cord and plug 120V -E= Cord and plug 277V * Minimum lamp load required: 20% of unit capacity ** Consult your sales representative TYPE: CATALOG #: SPEC GRADE NOTES: LC Series 6 and 12 Volt Steel Enclosure Features Dimensions Dimensions are approximate and subject to change. EF18 Cabinet Size Accessories (order as a separate item) SUFFIX DESCRIPTION Mounting bracket (cabinet B) B2 Mounting shelves (cabinet B) MP3-EG Mounting shelves (cabinet C) MP6-EG Mounting shelves (cabinet D) MP12 Wire Guard (cabinet B & cabinet C) WG3-E Wire Guard (cabinet D) WG4-E COMMERCIAL • Each unit comes with two (2) EF-18 heads with 9 watt high intensity incandescent lamps (standard). One or three heads available as options • All-steel construction with an off-white baked enamel finish • Contains sealed maintenance-free Lead-Calcium (Immobilized Electrolyte) batteries • PulsePlus Charger circuitry offers 120/277VAC, input 60 Hz., 0.3/0.15 Amps (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Removable front panel • UL Listed. Complies with NEC, Life Safety Code and OSHA. Approved for use in the Commonwealth of Pennsylvania and New York City • 3-year full warranty, excluding lamps and fuses EF9 Dimensions a b c d B 16-3/8” // 14-3/4” 16-1/8” 5-7/16” 10-1/4” C 18-3/8” // 16-3/4” 16-1/2” 7-1/4” 12-1/4” D 18-3/8” // 16-3/4” 27” 7-1/4” 12-1/4” Unit Rating Furnished standard with two 9 watt High Intensity Incandescent lamps. D.C. Model Number Voltage Watts to 87-1/2% of rated battery voltage* # of Cabinet Load size Fuses 1-1/2 hrs 2 hrs 4 hrs 8 hrs Lead-Calcium (immobilized electrolyte) 6 LC87-2 87 70 41 24 2 B 6 LC100-2 100 77 47 24 2 C 6 LC175-2 175 140 82 48 2 C 6 LC200-2 200 168 96 48 2 C 12 12LC150-2 150 120 66 36 2 C 12 12LC175-2 175 140 85 48 2 C 12 12LC200-2 200 168 96 48 2 C 12 12LC300-2 300 240 132 72 2 D 12 12LC350-2 350 280 170 96 2 D 12 12LC400-2 400 336 192 95 2 D * National Electrical Code Specification = New York City Approved How to Order COLOR Blank= Off white B= Black SERIES/CAPACITY LC87= 6V-87W Lead-Calcium LC100= 6V-100W Lead-Calcium LC175= 6V-175W Lead-Calcium LC200= 6V-200W Lead-Calcium 12LC150= 12V-150W Lead-Calcium 12LC175= 12V-175W Lead-Calcium 12LC200= 12V-200W Lead-Calcium 12LC300= 12V-300W Lead-Calcium 12LC350= 12V-350W Lead-Calcium 12LC400= 12V-400W Lead-Calcium # OF LAMPS -0= No head -1= 1 head -2= 2 heads -3= 3 heads HEAD STYLE Blank= EF18 (PAR 36 plastic) 28= EF28 (PAR 36 metal) 9= EF9 (mini plastic) 10= EF10 (small plastic MR16) 150= EF150 (MR16 lamp heads) LAMP TYPE H_= Halogen bi-pin I_= Incandescent DC-bayonet U_= Incandescent sealed-beam** X_= Halogen sealedbeam** Z_= Incandescent wedge M_= Halogen MR16* LA= 6V-4W, LED MR16* LG= 12V-4W, LED MR16* LI= 12V-5W, LED MR16* LJ= 12V-6W, LED MR16* * Available with EF10 & 150 only ** Available with EF18 & EF28 only NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: BLC87-128HB-A 41 OPTIONS Blank= No options -AD= Advanced Diagnostics (audible)* -ADNA= Advanced Diagnostics (non-audible)* -NEX= NEXUS® wired** -NEXRF= NEXUS® wireless** -A= Ammeter -V= Voltmeter -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -K= Lamp Disconnect Switch -CP= Cord and plug 120V*** -E= Cord and plug 277V*** *Minimum lamp head required: 20% of unit capacity ** Consult your sales representative *** Standard cord is 3 ft. TYPE: CATALOG #: SPEC GRADE NOTES: LS Series 6 and 12 Volt Steel Enclosure Dimensions COMMERCIAL Features Dimensions are approximate and subject to change. • Each unit comes with two (2) EF-18 heads with 9 watt high intensity incandescent lamps (standard). One or three heads available as options • Constructed of 20-gauge steel with an off-white baked enamel finish • Available with sealed, maintenance-free Nickel-Cadmium, or Lead-Calcium batteries • Power Requirements: 120/277 VAC 60Hz, 0.3/0.15A • PulsePlus Charger circuitry offers 120/277 VAC 60 Hz., 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Removable front panel • UL Listed. Complies with NEC, Life Safety Code and OSHA. Approved for use in the Commonwealth of Pennsylvania and New York City • 3-year full warranty, excluding lamps and fuses Accessories (order as a separate item) EF18 SUFFIX DESCRIPTION Mounting bracket (cabinet A) B1 Mounting bracket (cabinet B) B2 Mounting shelves (cabinet B) MP3-EG Mounting shelves (cabinet C) MP6-EG Wire Guard (cabinet A) WG2-E Wire Guard (cabinet B & cabinet C) WG3-E EF9 Dimensions Cabinet Size a b A 14-5/8” // 13” B C 12-3/4” c d 3-1/8” 8-1/2” 16-3/8” // 14-3/4” 16-1/8” 5-7/16” 10-1/4” 18-3/8” // 16-3/4” 16-1/2” 7-1/4” 12-1/4” Unit Rating Furnished standard with two 9 watt High Intensity Incandescent lamps. UNIT EQUIPMENT - NO REMOTE CAPABILITY Nickel-Cadmium 6 LSC18-2 Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 4 hrs 4 hrs 18 12 9 6 Lead-Calcium 6 LSM18-2 12 Sealed Maintenance-Free Battery Types D.C. Voltage Model Number 12 10 7 # of Load Fuses Cabinet size 1 A 1 A UNIT EQUIPMENT - WITH REMOTE CAPABILITY 1-1/2 hrs Nickel-Cadmium Lead-Calcium 2 hrs 3 hrs 8 hrs 6 LSC25-2 25 18 9 – 1 A 12 12LSC36-2 36 21 12 6 1 A 12 12LSC50-2 50 36 18 10 1 A 24 24LSC100-2 100 73 37 20 2 B 6 LSM27-2 27 18 10 6 1 A 6 LSM36-2 36 25 14 7 1 A 6 LSM54-2 54 37 21 12 1 A 6 LSM81-2 81 54 36 18 2 B 6 LSM110-2 110 72 40 24 2 B 6 LSM162-2 162 108 60 48 2 C 6 LSM200-2 200 144 80 48 2 C 12 12LSM36-2 36 25 14 7 1 A 12 12LSM54-2 54 37 21 12 1 A 12 12LSM110-2 110 72 40 24 2 B 12 12LSM162-2 162 108 60 36 2 C 12 12LSM220-2 220 144 80 48 2 * National Electrical Code Specification C = New York City Approved 42 TYPE: CATALOG #: SPEC GRADE NOTES: LS Series 6 and 12 Volt Steel Enclosure How to Order COLOR SERIES/CAPACITY LSC Series LSC18= 6V-18W Ni-Cd LSC25= 6V-25W Ni-Cd 12LSC36= 12V-36W Ni-Cd 12LSC50= 12V-50W Ni-Cd 12LSC72= 12V-72W Ni-Cd # OF LAMPS -0= No head -1= 1 head -2= 2 heads -3= 3 heads HEAD STYLE LAMP TYPE/WATTAGE OPTIONS Blank= EF18 (PAR 36 plastic) 28= EF28 (PAR 36 metal) 9= EF9 (mini plastic) 10= EF10 (small plastic MR16) 150= EF150 (MR16 lamp heads) Blank_= 6V-9W and 12V-9W incandescent wedge base H_= Halogen bi-pin I_= Incandescent DC-bayonet U_= Incandescent sealed-beam** X_= Halogen sealed-beam** Z_= Incandescent wedge M_= Halogen MR16* LA= 6V-4W, MR16 LED* LG= 12V-4W, MR16 LED* LL= 24V-4W, MR16 LED* LI= 12V-5W, MR16 LED* LJ= 12V-6W, MR16 LED* Blank= No options -AD= Advanced Diagnostics (audible)* -ADNA= Advanced Diagnostics (non-audible)* -NEX= NEXUS® wired (consult your sales representative)* -NEXRF= NEXUS® wireless (consult your sales representative)* -V= Voltmeter -A= Ammeter -CP= Cord and plug 120V only** -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -E= Cord and plug 277V LSM Series LSM18= 6V-18W Lead-Calcium LSM27= 6V-27W Lead-Calcium LSM36= 6V-36W Lead-Calcium LSM54= 6V-54W Lead-Calcium LSM81= 6V-81W Lead-Calcium LSM110= 6V-110W Lead-Calcium LSM162= 6V-162W Lead-Calcium LSM200= 6V-200W Lead-Calcium 12LSM36= 12V-36W Lead-Calcium 12LSM54= 12V-54W Lead-Calcium 12LSM105= 12V-105W Lead-Calcium 12LSM110= 12V-110W Lead-Calcium 12LSM162= 12V-162W Lead-Calcium 12LSM220= 12V-220W Lead-Calcium * Available with EF10 & EF150 only ** Available with EF18 & EF28 only NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: BLSC18-110LA-AD 43 * Minimum lamp load required: 20% of unit capacity. Not available with 12V-72W Ni-Cd **Standard cord is 3 ft. COMMERCIAL Blank= Off white B= Black enclosure TYPE: CATALOG #: SPEC GRADE NOTES: 24 LS & 24 LC Series 24 Volt Steel Enclosure COMMERCIAL Features Dimensions Dimensions are approximate and subject to change. • Each unit comes with two (2) EF-18 heads with 9 watt high intensity incandescent lamps (standard) • All-steel construction with an off-white baked enamel finish • Available with sealed, maintenance-free Nickel-Cadmium, Long Life Lead, Lead-Calcium (Immobilized Electrolyte), or Lead-Calcium batteries • PulsePlus Charger circuitry offers 120/277VAC, input 60 Hz., 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Removable front panel • UL Listed. Complies with NEC, Life Safety Code and OSHA. Approved for use in the Commonwealth of Pennsylvania • 3-year full warranty, excluding lamps and fuses Accessories (order as a separate item) SUFFIX DESCRIPTION Mounting bracket (cabinet B) B2 Mounting shelves (cabinet B) MP3-EG Mounting shelves (cabinet C) MP6-EG Cabinet Size Mounting shelves (cabinet D) MP12 B 16-3/8” 16-1/8” Wire Guard (cabinet A) WG2-E C 18-3/8” 16-1/2” 7-1/4” 12-1/4” Wire Guard (cabinet B & C) WG3-E D 18-3/8” 27” 7-/4” 12-1/4” Wire Guard (cabinet D) WG4-E Dimensions a b c 5-7/16” d 10-1/4” Unit Rating Furnished standard with two 9 watt High Intensity Incandescent lamps. Sealed Maintenance-Free Battery Types Nickel-Cadmium Long Life Lead Lead-Calcium (Immobilized Electrolyte) Lead-Calcium 24 24LSC72-2 Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 3 hrs 4 hrs 72 42 24 12 2 B 24 24LSC100-2 100 73 37 20 2 B 24 24LSE72-2 72 48 26 14 2 B 24 24LSE110-2 110 74 43 21 2 B 24 24LSE320-2 320 300 148 76 2 D 24 24LC300-2 300 240 132 72 2 D 24 24LC350-2 350 280 168 96 2 D 24 24LC400-2 400 336 192 96 2 D 24 24LSM110-2 110 72 40 24 2 B 24 24LSM220-2 220 144 80 48 2 C D.C. Voltage Model Number # of Load Fuses Cabinet size *National Electrical Code Specification. How to Order COLOR Blank= Off white B= Black enclosure SERIES/CAPACITY LSC Series 24LSC100= 24V-100W Ni-Cd LSE Series 24LSE72= 24V-72W Long Life Lead 24LSE110= 24V-110W Long Life Lead 24LSE320= 24V-320W Long Life Lead LSM Series 24LSM110= 24V-110W Lead-Calcium 24LSM220= 24V-220W Lead-Calcium LC Series 24LC300= 24V-300W Lead-Calcium 24LC350= 24V-350W Lead-Calcium 24LC400= 24V-400W Lead-Calcium # OF LAMPS -0= No heads -1= 1 head -2= 2 heads -3= 3 heads HEAD STYLE Blank= EF18 (PAR 36 plastic) 28= EF28 (PAR 36 metal) 9= EF9 mini plastic 10= EF10 mini plastic MR16 32= EF32 cylinder lamp heads 150= EF150 MR16 lamp heads Example: 24LSC100-2150MH 44 LAMP TYPE OPTIONS I_= Incandescent DC-bayonet Z_= Incandescent wedge M_= Halogen MR16* LL= 24V-4W, MR16 LED Blank= No options -AD= Advanced diagnostics* -ADNA= Diagnostics non-audible* -NEX= Nexus® wired -NEXRF= Nexus® wireless -V= Voltmeter (A cabinet units. Choose A or V only) -A= Ammeter* -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -CP= Cord and plug 120V** -E= Cord and plug 277V * Available with EF10 & 150 only ** Available with EF18 & EF28 only NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 * Minimum lamp load required: 20% of unit capacity. Not available with 24V-100W Ni-Cd ** Standard cord is 3 ft. TYPE: CATALOG #: SPEC GRADE NOTES: X10 LED Series Steel LED Exit & Mini- System Combination Units Features Dimensions Dimensions are approximate and subject to change. Mini System Model Dimensions Exit Sign (SNX) Model Dimensions 4-5/8” 12-1/8” 1-1/4” 7-3/8” 12-1/4” 7-5/8” 7-3/8” 4-5/8” 1-1/4” 12-1/8” 2-1/8” 6-1/8” Power Consumption (Mini-System Combination Units) 120/277VAC 60Hz, 03/0.15 Amp. Unit Rating (Total DC power available for local and remote emergency lights.) Choice of Models Mini-systems UNIT EQUIPMENT - MINI-SYSTEM Lead-Calcium 6 SBX14 Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 3 hrs 4 hrs 30 20 15 10 Nickel-Cadmium 6 STX14 24 Battery Type D.C. Voltage Model Number 18 12 Remote capacity L-SBX14 models No EF9 mounted heads = 30W remote capacity Two 5.4-watt EF9 mounted heads = 19W remote capacity Remote capacity L-STX14 models No EF9 mounted heads = 24W remote capacity Two 5.4-watt EF9 mounted heads = 13W remote capacity 9 *National Electrical Code Specification Exit Sign Power Consumption (LED Exit Signs) Model AC Specs AC input: universal 2-wire 120 to 277VAC 50/60Hz AC/DC models: universal 2-wire 6 to 24VDC Self-Powered models: long-life, sealed Nickel-Cadmium battery DC Specs AC-only: L-X14 120 to 277 VAC Less than 1.5W – – AC/DC: DCL-X14 120 to 277 VAC Less than 1.5W 6 to 24 VDC Less than 1.5W Self-Powered: L-SNX14 120 to 277 VAC Less than 3W NickelCadmium Min. 90 minutes Mini-System 120/277VAC Accessories (order as a separate item) SUFFIX DESCRIPTION 0.3/0.15 Amp *National Electrical Code Specification White Pendant P-WT* Black Pendant P-BK* Wire Guard Ceiling Mount (Exit Only) WG5-E Wire Guard End Mount (Exit Only) WG5-E Wire Guard For Wall Mount (AC Only, AC/ DC & Self-Powered Exit Signs) WG12-E Wire Guard For Wall Mount (Mini System or Combo) WG6-E How to Order DC INPUT Blank= No DC input DC= 6V to 24VDC* SERIES L= LED Exit sign HOUSING COLOR W= White B= Black A= Textured aluminum BATTERY TYPE Exit Sign Models X14= AC only or AC/DC SNX14= Ni-Cd 120/277VAC input (only for DC) Mini System Models SBX14= 6V-30W Lead-Calcium STX14= 6V-24W Nickel-Cadmium * Only available on Exit Sign models #- Other color LEGEND COLORS # OF HEADS R= Red G= Green Blank= No head -1= 1 head -2= 2 heads Open face RW= Red/white WR= White/red GW= Green/white WG= White/green LAMP TYPE H_= Halogen bi-pin I_= Incandescent DC-bayonet U_= Incandescent sealed-beam** X_= Halogen sealed-beam** Z_= Incandescent wedge M_= Halogen MR16* L_= MR16 LED* * Available with 10 & 150 lamp head only ** Available with EF18 only NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 (Open face required with special wording legends) Example: DCLWX14R-VR 45 OPTIONS Blank= No options -NEX= NEXUS® wired (consult your sales representative)* -NEXRF= NEXUS® wireless (consult your sales representative)* D1= Time Delay (5 minutes) D2= Time Delay (10 minutes) D3= Time Delay (15 minutes) -2CKT= Dual circuit (AC Only) -FL= Flasher* -FZ= Flasher buzzer combination* -FA= Fire alarm activated flasher* -L= Brushed aluminum face -VR= Vandal-resistant screws * Mini-System Combination Units only COMMERCIAL • Red or green LED light sources. • Constructed of rugged 20 gauge steel. Off-white or black epoxy powder finish • Available with sealed, maintenance-free Nickel-Cadmium, Long Life Lead or Lead-Calcium batteries • PulsePlus charger circuitry offers 120/277VAC 60Hz, 0.3/0.15A (other inputs available), fused output circuit, pilot and charge indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Universal mounting, single or double face, stencil or open face are available • UL Listed. Exceeds UL Exit Visibility Requirement • 3-year full warranty TYPE: CATALOG #: SPEC GRADE NOTES: Prestige™ Economizer Series Recessed Mount Edge-Lit Exit Sign Dimensions Dimensions are approximate and subject to change. • Rugged, 20-gauge steel back box • Equipped with bar hanger kit for easy installation • Formed steel flat trim plate • Choice of finishes: textured aluminum or off-white • Acrylic panel with curved contour provides superior clarity and illumination • Legend with a choice of red or green letters • Choice of legend background: clear, white (red legend only) or mirror • Stick-on translucent directional chevrons for field installation • Simple, two-wire universal AC input (120V to 277VAC 50/60Hz) prevents installation errors • Sealed Nickel-Cadmium batteries provide 90 minutes of emergency lighting • Simple, two-wire universal DC input: 6V to 24 VDC • Long-life LED light for low maintenance costs and superior illumination • Energy efficient power consumption: less than 2.5W for single or double face legends • UL 924 Listed 16” 7-1/8” 7” 15-1/8” 11-3/4” 4-1/4” 3-3/8” 3-3/8” COMMERCIAL Features Power Consumption Model AC Specs DC Specs AC-only 120 to 277VAC Less than 1.5W – – AC/DC-remote 120 to 277VAC Less than 1.5W 6 to 24VDC Less than 1.5W Self-Powered 120 to 277VAC Less than 2.5W Ni-Cd battery Min. 90 minutes How to Order (Surface Mount Series) HOUSING COLOR TA= Textured aluminum OW= Off white SERIES TRIM PE= AC PES= AC/DC PEN= Self-Powered F= Recessed flat trim FACE 1= Single face 2= Double face LEGEND COLOR RC= Red on clear* RW= Red on white RM= Red on mirror GC= Green on clear* GM= Green on mirror *Single face only Example: TAPEF1RC 46 TYPE: CATALOG #: SPEC GRADE NOTES: Prestige™ Economizer Series Slim Profile Surface Mount LED Edge-Lit Exit Sign Features Dimensions • Acrylic panel with curved contour provides superior clarity and illumination. Long-life LED light for low maintenance costs and superior illumination • Legend with a choice of red or green six-inch letters, and easy-to-add field-installed stick-on translucent directional arrows. Choice of legend background: clear, white or mirror • Slim-profile extruded aluminum housing with slim-profile Die-Cast aluminum canopy. Choice of finishes: textured aluminum or off-white • Energy efficient power consumption: less than 3W for Self-Powered version and less than 2 watts for AC only single or double face • Available with sealed Nickel-Cadmium batteries that provide 90 minutes of emergency lighting • Simple, two-wire universal AC input (120V to 277VAC 60Hz) prevents installation errors. Simple, two-wire universal DC input: 6V to 24VDC • Universal surface mounting: wall, ceiling or end mount. Click-to-open housing door allows easy access to the panel and electrical wiring. For recessed mount please consult your sales representative • UL 924 Listed • 3-year full warranty, subject to proper installation and maintenance Dimensions are approximate and subject to change. 11-1/4” 11-1/8” 10-1/8” 12-1/2” Wall Mount End Mount 4-1/4” Accessories (order as a separate item) 1-5/8” 12” SUFFIX PE-P-WH* Black PE-P-BK* 10-5/8” DESCRIPTION White Power Consumption Model AC Specs DC Specs AC-only 120 to 277VAC Less than 2W – – AC/DC 120 to 277VAC Less than 2W 6 to 24VDC Less than 1.5W Self-Powered 120 to 277VAC Less than 3W Ni-Cd battery Min. 90 minutes Ceiling Mount How to Order (Surface Mount Series) HOUSING COLOR TA= Textured aluminum OW= Off white SERIES FACE PE= AC PES= AC/DC PEN= Self-Powered 1= Single face 2= Double face LEGEND COLOR RC= Red on clear* RW= Red on white RM= Red on mirror GC= Green on clear* GM= Green on mirror * Single face only Example: TAPE1RC 47 COMMERCIAL 12” TYPE: CATALOG #: SPEC GRADE NOTES: Preceptor™ Series Die-Cast Aluminum LED Exit Sign Dimensions Dimensions are approximate and subject to change. • Housing of Die-Cast aluminum in a variety of finishes • Slim-line canopy for top and end mounting • Universal mounting for wall, end, or ceiling • Universal, field-selectable knock-out chevrons • Long-life red or green LED light source. • Dual voltage input: 120/277VAC 60Hz • Low power consumption: less than 3W in any configuration • Self-Powered models with sealed maintenance-free Nickel-Cadmium batteries • UL 924 Listed • 5-year full warranty 8-5/8” 5-1/2” 4-3/8” 9-1/8” COMMERCIAL Features Power Consumption Model AC Specs DC Specs AC-only 120/277VAC Less than 2.5W – – AC/DC-remote 120/277VAC Less than 2W 6 to 24VDC Less than 1.5W Self-Powered 120/277VAC Less than 3W Ni-Cd battery Min. 90 minutes Self-Powered with Diagnostic 120/277VAC Less than 2.8W Ni-Cd battery Min. 90 minutes 12-7/8” 1-7/8” How to Order HOUSING COLOR BA= Black body/aluminum face WW= White body/white face WA= White body/aluminum face BB= Black body/black face AA= Brushed aluminum body and face SERIES/MODELS Standard Models P= AC only (120/277 volts ) PU= 120/277VAC & 6 to 24VDC PXN= Self-Powered diagnostic Ni-Cd PDN= Self-Powered Ni-Cd, No AD # OF FACES 1= Single face 2= Double face LEGEND COLOR R= Red G= Green Open Face RW= Red on white GW= Green on white Optional Models P2C1= Dual AC circuit (2 x 120V) P2C2= Dual AC circuit (2 x 277V) PNEX= NEXUS® wired (consult your sales representative) PNEXRF= NEXUS® wireless (consult your sales representative) Note: Open face required with special wording legends Other colors available Example: BAPU2R 48 OPTIONS Blank= No options DL= Damp Location FZ= Flasher buzzer* FL= Flasher* FA= Fire alarm activated flasher (Not available with PDN) FBF= Flasher buzzer + fire alarm activated flasher* VR= Tamper-proof screws** VR1= Polycarbonate shield with tamper-proof screws** * PXN, PNEX and PNEXFR models only ** Please specify single or double face red or green TYPE: CATALOG #: SPEC GRADE NOTES: US Preceptor™ Recessed Series Die-Cast LED Exit Sign Features Dimensions Dimensions are approximate and subject to change. • LED light sources. Long life LEDs eliminate the twice-a-year re-lamping typical of incandescent lamps • Self-Powered models are self contained; batteries and circuitry are located inside the exit housing • Available with sealed maintenance-free Nickel-Cadmium batteries to provide 90 minutes of emergency illumination • Two-wire universal input 120 through 277VAC, 60Hz • Diagnostic / Self Test circuitry is standard on all Self-Powered models. This circuitry is programmed to ensure the exit sign’s readiness and reliability by continuously monitoring every critical function of the unit. If a problem occurs, a single “service required” indicator illuminates immediately. A detailed diagnostic display sign that will further indicate the nature of the fault is located on the inside of the exit sign, out of sight from the general public. The self test will test the unit for 30 seconds every 30 days, 30 minutes every 60 days and 90 minutes annually • Unaffected by the vibrations, ambient temperature swings and typical power surges detrimental to standard exit light sources • 5-year full warranty • UL Listed Fully Recessed Mount 11-7/8” 8-1/2” 9-1/4” 12-3/4” Choice of Models AC-Only Models: 120 through 277VAC, 60Hz universal input. Power Consumption AC-only 120 to 277VAC 1.4W – – “Self-Powered Models are self contained, batteries and circuitry are located inside the exit housing”: 1 20 through 277VAC, 50/60Hz universal input. Self-Powered 120 to 277VAC 1.7W Ni-Cd battery Min. 90 minutes Sealed maintenance free Nickel-Cadmium battery provides 90 minutes of emergency illumination. Model AC Specs DC Specs How to Order RECESSED FR= Fully recessed FACE COLOR Blank= Aluminum face B= Black face W= White face PB= Polished brass face CH= Polished chrome face BZ= Dark bronze face SERIES LEDP= AC only LEDPXN= Self-Powered Ni-Cd # OF FACES LEGEND COLOR 1= Single face R= Red G= Green RW= Red on white (Open face) GW= Green on white (Open face) Custom color vailable, consult your sales representative Example: FRBLEDP1R-VR1-N 49 OPTIONS FZ= Flasher buzzer (Self-Powered) FA= Fire alarm activated flasher (Self-Powered) DL= Damp Location VR= Vandal-resistant screws VR1= Polycarbonate shield with tamper-proof screws -2CKT= Dual circuit operation (AC models only) VERSION -N= New design COMMERCIAL 4” TYPE: CATALOG #: SPEC GRADE NOTES: Preceptor™ Remote Capacity Series Die-Cast Aluminum Remote Capacity Exit Sign Dimensions Dimensions are approximate and subject to change. • Long-life, high-performance, low power consumption, red or green LEDs provide even illumination in normal and emergency modes. • Constructed of Die-Cast aluminum with a power canopy that houses the battery, input transformer and printed circuit board. The standard unit color is a black frame with a brushed aluminum face. Specify single or double face as required. • Available with sealed maintenance-free Lead-Calcium or Nickel-Metal Hydride (cadmium-free, environmentally friendly) batteries. • Can be ceiling, end or back mounted to the power canopy. The power canopy surface mounts directly to the junction box (supplied by others). • UL Listed. Complies with NEC, Life Safety Code and OSHA. • 5-year full warranty. Ceiling Mount Back Mount 12-7/8” 6-1/4” 1-7/8” Accessories (order as a separate item) 10-7/8” 12-7/8” 8-1/8” 8-1⁄8” 8-1/2” 8-1/2” SUFFIX DESCRIPTION Wire Guard, Back Mount WG13-E Wire Guard, Ceiling Mount WG14-E 1-7/8” Application Flexibility Lead-Calcium Models (RCL) - Sealed, maintenance-free Lead-Calcium batteries power the exit sign for an estimated period of 20+ hours minimum with no remote load or 90-minutes run time with 9 watts remote load. End Mount 15-1/4” Nickel-Metal Hydride Models (RCN) - Sealed, maintenance-free Nickel-Metal Hydride batteries power the exit sign for an estimated period of 20+ hours minimum with no remote load or 90-minutes run time with 12 watts remote load. 1-7/8” Nickel-Metal Hydride Models (RCX) - Sealed, maintenance-free Nickel-Metal Hydride batteries power the exit sign for an estimated period of 40+ hours minimum with no remote load or 90-minutes run time with 24 watts remote load. 8-1/2” 12-7/8” 6-1/4” COMMERCIAL Features 8-1/8” Power Consumption & Unit Rating Chart AC Specs Series AC Input RCL RCN 120/277VAC, 60Hz 6V DC SPECS - WATTS TO 87-1/2% OF RATED BATTERY VOLTAGE* Battery 1-1/2 hrs. 2 hrs. 3 hrs. Lead-Calcium 9 – – – 6V NiMH 12 9 – – 6V NiMH 24 18 12 9 Maximum 0.13/0.06A 15W RCX Voltage 4 hrs. * National Electrical Code Specification How to Order HOUSING COLOR SERIES BATTERY TYPE # OF FACES LEGEND COLOR BA= Black body/aluminum face BB= Black body/black face WW= White body/white face WA= White body/aluminum face AA= Brushed aluminum body and face P= Preceptor RCL= Sealed Lead-Calcium, 9W remote capacity RCN= Sealed Nickel-Metal Hydride, 12W remote capacity RCX= Sealed Nickel-Metal Hydride, 24W remote capacity 1= Single face 2= Double face R= Red G= Green RW= Red on white (Open face required for special wording) GW= Green on white (Open face required for special wording) Example: BAPRCL2R 50 OPTIONS AD= Advanced Diagnostics (audible) ADNA= Advanced Diagnostics (non-audible) D1= Time Delay (5 minutes) D2= Time Delay (10 minutes) D3= Time Delay (15 minutes) FZ= Flasher buzzer FA= Fire alarm activated flasher DL= Damp Location VR= Vandal-resist screws VR1= Vandal-resistant polycarbonate lens and screws TYPE: CATALOG #: Special Wording Series Custom Illuminated Signage Features SPEC GRADE NOTES: Illuminated Signage • The same sturdy construction and electrical design used in our exit signs is used to produce our custom-worded, illuminated signage • Sign bodies are available in steel, extruded and Die-Cast aluminum, weatherproof, flame-retardant polycarbonate, high impact thermoplastic and recessed housing • Also available with combination units • Custom wording with available in any style of lettering, any language, and alphabet, any special characters • Graphics can include logos, standard symbols and custom art • Color choices for sign bodies, message and faceplate panel • llumination from LED (light-emitting diodes); other light sources available • Contact your local Emergi-Lite® sales representative to discuss your specific requirements Custom-worded, illuminated signage is available using the same sturdy construction and electrical design as Emergi-Lite® exit signage. A wide range of sign body options and color choices are available to suit any application. COMMERCIAL 51 SPEC GRADE SPEC GRADE INDUSTRIAL Table of Contents 54 KS Steel Series 66-67 Survive-All™ SV Series 55 KS Series 68-69 Survive-All™ SVX Combo Series 56 EXC Series 70-71 Survive-All™ SVX Exit Series 57 EFEP Series 72 Survive-All™ EF39 & EF40 Series 58 EFXP Series 73 HZM Series 59 Ever-Lite™ Self-Luminous Series 74 Survive-All™ SVH Series 60 Survive-All™ SVXH Series 61 Survive-All™ SVXHZ Series 62 Survive-All™ EF41 Series 63 IL Series 64-65 53 INDUSTRIAL Hazardous Location Information HAZARDOUS LOCATION INFORMATION Hazardous locations are areas where a potential for explosion or fire exists due to the presence of certain gases, liquid vapors, combustible dusts or fiber particles suspended in the air. The National Electrical Code®, NEMA, OSHA, UL, NFPA Life Safety Standards, as well as State and Local codes prescribe the use of emergency lighting equipment. This equipment itself must not contribute to the ignition of flammable or explosive substances present in the location. Emergi-Lite® offers a complete line of emergency lighting equipment for use in hazardous locations. Hazardous Location Classifications Class l (NEC-500-5) Areas in which flammable gases or vapors may be present in sufficient quantities to be explosive or ignitable. Class ll (NEC-500-6) Areas made hazardous by the presence of combustible dust. Class lll (NEC-500-7) Areas in which there are easily ignitable fibers or flyings present, due to the type of material being handled, stored or processed-but in which such fibers or flyings are not likely to be in suspension in the air in quantities sufficient to produce ignitable mixtures. Division 1 (NEC-500-5,6 & 7) Normal Situation: A hazard is present in the everyday normal production operation or during frequent repair and/or maintenance activity. Division 2 (NEC-500-5,6 & 7) Abnormal Situation: Potentially hazardous material is expected to be safely confined within closed containers or closed systems, and will be present in the atmosphere only through accidental rupture, breakage, or abnormal operation. Group A, B, C & D (NEC-500-3) Gases and vapors in Class l locations are classified into four groups, by the code A, B, C, and D. These materials are grouped according to the ignition temperature of the substance, its explosion pressure and other flammability characteristics. Groups E F & G (NEC-500-3) Combustible dust in Class ll locations are classified according to ignition temperature and the conductivity of the hazardous substance. NEMA Enclosure Typical Class l Locations: • Petroleum refineries, and gasoline storage and dispensing areas. • Industrial firms that use flammable liquids in dip tanks for cleaning parts or other operations • Petrochemical companies that manufacture chemicals from gas and oil. • Dry cleaning plants where vapors from cleaning fluids can be present. • Companies that have areas dedicated for spraying products with paint or plastics. • Aircraft hangars and fuel servicing areas. • Utility gas plants, and operations involving storage and handling of liquified petroleum gas or natural gas. Typical Class ll Locations: • Grain elevators, flour and feed mills. • Plants that manufacture, use or store magnesium or aluminum powders. • Plants that have chemical or metallurgical processes, producers of plastics, medicines, and fireworks etc. • Producers of starch or candies. • Spice grinding plants, sugar plants and cocoa plants. • Coal preparation plants and other carbon handling or processing areas. Typical Class lll Locations: • Textile mills, cotton gins, cotton seed mills and flax processing plants. • Clothing manufacturing plants • Any plant that shapes pulverizes or cuts wood and creates saw dust or shavings. FOR MORE INFORMATION CONSULT NEC CODE. Type 1 - Intended for use indoors primarily to prevent accidental contact of personnel with the enclosed equipment. Type 2 - Intended for use indoors to protect the enclosed equipment against falling non-corrosive liquids and falling dirt. Type 3 - Intended for use outdoors to protect the enclosed equipment against rain, windblown dust, sleet and external ice formation. Type 3R - Intended for use outdoors to protect the enclosed equipment against falling rain, sleet and external ice formation. Type 4 - Intended for use indoors and outdoors to protect the enclosed equipment against windblown dust, rain, splashing water and hose directed water. Type 5 - Intended for indoor use primarily to protect against dust and falling dirt. Type 6 - Intended for indoor or outdoor use primarily to provide a degree of protection against the entry of water during occasion al temporary submersion at a limited depth. Type 6P Intended for indoor or outdoor use primarily to provide a degree of protection against the entry of water during prolonged s ubmersion at a limited depth. Type 7 - Intended for use indoors in locations classified as Class l, Groups A, B, C, or D as defined in the National Electrical Code®. Type 8 - Intended for indoor or outdoor use in locations classified as Class l, Groups A, B, C, & D as defined in the National Electrical Code®. Type 9 - Intended for indoor locations classified as Class ll, Groups E, F & G, as defined in the National Electrical Code®. Type 10 - Enclosures are constructed to meet the applicable requirements of the Mine Safety and Health Administration. Type 11 - Intended for indoor use primarily to provide, by oil immersion, a degree of protection to enclosed equipment against the corrosive effects of liquids and gases. Type 12 - Intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping noncorrosive liquids. Type 12K - Enclosure with knockouts intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids other than at knockouts. Type 13 - Intended for indoor use primarily to provide a degree of protection against dust, spraying of water, oil, and noncorrosive coolant. TYPE: CATALOG #: NEMA-4X SPEC GRADE NOTES: Survive-All™ SV Series NEMA-4X, NSF, Vandal-Resistant Housing Battery Unit Features Dimensions Dimensions are approximate and subject to change. 17-3⁄4” 7” Universal Bracket Accessories (order as a separate item) PMK KIT (screws included) PART NUMBER DESCRIPTION Additional special bit for tamper-proof screws 690.0454-E Universal bracket (for mounting on poles, I-beams or strut metal framing) PMK-E BEAM MOUNTING STRUT MOUNTING Unit Rating UNIT EQUIPMENT - WITH REMOTE CAPABILITY Sealed Maintenance-Free Battery Types Applications • Hosedown areas / car washes • Food processing / preparation facilities • Marine locations • Chemical plants • Schools and other public facilities • Parking garages • Food processing / preparation facilities 5-3⁄4” • Transit platforms • Sports arenas / swimming pools • Security areas / prisons • Warehouse and cold storage facilities • Heavy industrial facilities Lead-Calcium Nickel-Cadmium Nickel-Metal Hydride Note: Units installed outdoors must be in a shaded area (Lead-Calcium batteries) Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 3 hrs 4 hrs 18 12 8 – 24 16 12 8 36 24 20 14 54 36 27 20 24 18 12 8 40 27 20 14 60 40 30 20 * National Electrical Code Specification. How to Order COLOR B= Black G= Gray W= White SERIES SV18M= 6V-18W Lead-Calcium 12SV24M= 12V-24W Lead-Calcium 12SV36M= 12V-36W Lead-Calcium 12SV54M= 12V-54W Lead-Calcium 12SV24N= 12V-24W Nickel-Cadmium* 12SV40N= 12V-40W Nickel-Cadmium* 12SV60H= 12V-60W NiMH* # OF LAMPS -2= 2 Lamps LAMPS LA= 6V-4W, MR16 LED LG= 12V-4W, MR16 LED LI= 12V-5W, MR16 LED LJ= 12V-6W, MR16 LED MI= 6V-6W, MR16 MK= 12V-12W, MR16 MW= 12V-20W, MR16-IR *= Suitable for Damp-Locations 50°F to 104°F (10°C to 40°C) DIAGNOSTICS -DA= Advanced Diagnostics (audible)* -D= Advanced Diagnostics (non-audible)* -NEX= NEXUS® wired (consult your sales representative) -NEXRF= NEXUS® wireless (consult your sales representative) * Minimum lamp load: 20% of unit capacity Example: B12SV36M-2LG-DCW4 55 OPTIONS Blank= No options CW4= Cold weather -40°F to 104°F (-40°C to +40°C)* * Only available with 12SV24M & 12SV36M Not available with NEX and NEXRF option INDUSTRIAL •E quipped with a tool-less MR16 swivel lamp assembly to provide precise beam control. Choice of MR16 LED or halogen lamps of 6V and 12V •F ully gasketed cast aluminum back plate with clear, UV resistant polycarbonate cover. Tamper-proof screws and bit are included. Available in black, white or gray •S tandard temperature 50°F to 104°F (10°C to 40°C). •A vailable with sealed, maintenance-free Nickel-Cadmium (UL Listed for damp and wet locations), or Lead-Calcium batteries •S tandard 120/277VAC 0.3/0.15A input. Non-audible advanced diagnostic charger board, 15 minute Time Delay and lamp disconnect. Audible warning and Time Delay functions can be enabled or disabled during installation. Nonobtrusive, magnetic test switch. Micro-controller diagnostic system tests, detects and indicates battery, charger circuitry or MR16 lamp failures. •W all, strut or beam mounting •U L Listed. Certified to meet UL924 standards, 90 minutes of emergency operation, NEMA-4X rated for high abuse areas, wet locations and cold weather (-40°F/-40°C) applications, NSF Certified for use in food processing plants •3 -year full warranty, excluding lamps and fuses TYPE: CATALOG #: SPEC GRADE NEMA-4X Survive-All™ SVX Series NEMA-4X, Vandal Resistant and Harsh Environment Combination Unit Features Dimensions Dimensions are approximate and subject to change. •E ach unit comes with two (2) MR16 high intensity lamps (standard). Fully fieldadjustable lamp head assembly offers the option of selecting either a halogen lamp or a high efficiency white LED light source for optimum illumination over the path of egress. Exit light source LED •R ugged PVC body will not dent, peel or corrode. The sealed faceplate is constructed with a heavy duty, vandal-resistant polycarbonate cover and fastened with stainless steel tamper-resistant screws •A vailable with sealed, maintenance-free Nickel-Cadmium batteries • Advanced Diagnostic circuitry is standard on all Self-Powered models This circuitry is programmed to ensure the exit combination unit’s readiness and reliability by continuously monitoring every critical function of the unit. If a problem occurs, a single “Service Required” indicator illuminates immediately. A detailed diagnostic display that will further indicate the nature of the fault is located on the inside of the exit sign, out of sight from the general public. The self test will check the unit for a minimum of 30 seconds every 30 days, 30 minutes every 60 days and 90 minutes annually. PulsePlus Charger circuitry offers 120/277 volt input 60 Hz, 0.3/0.15 Amps (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensated charger, sealed relay, low voltage battery disconnect, brownout protection and lockout (automatic battery connect). Magnetically operated test switch •C an be wall, end or ceiling mounted •N EMA 4X* Rated. UL Listed. Listed for wet and Damp Locations 50°F to 104°F (+10°C/+40°C) •5 -year full warranty, excluding lamps and fuses 6-1/4” 3-7/16” Double Face Dimensions without heads Single Face Unit Rating Sealed Maintenance-Free Battery Types Nickel-Cadmium Accessories (order as a separate item) Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 3 hrs 4 hrs 12 9 – – 24 18 12 9 * National Electrical Code Specification. PART NUMBER Additional special bit for tamper-proof screws 690.0454-E Additional test magnet 199.0133-E Power Consumption Model Applications • Hosedown areas / car washes • Food processing / preparation facilities • Marine locations • Chemical plants • Schools and other public facilities • Parking garages 3/4” 3-7/8” 13-1/4” * Nema-4X Certified for wall or ceiling mounting only DESCRIPTION 9-3/16” 4-5/8” 12-5/8” INDUSTRIAL NOTES: AC Specs DC Specs (90 minutes) SVX12N 120/277VAC 0.12/0.06A 13W 6V 12W SVX24N 120/277VAC 0.17/0.08A 19W 12V 24W • Transit platforms • Sports arenas / swimming pools • Security areas / prisons • Warehouse and cold storage facilities • Heavy industrial facilities Note: Units installed outdoors must be in a shaded area (Lead-Calcium batteries) How to Order HOUSING/FACE COLOR SERIES/ CAPACITY WW= White/white WB= White/black WA= White/ aluminum BB= Black/black BW= Black/white BA= Black/ aluminum GA= Gray/ aluminum GW= Gray/white GB= Gray/black SVX12N= 6V-12W SVX24N= 12V-24W FACES 1= Single face 2= Doubleface LEGEND COLOR R= Red legend G= Green legend DIAGNOSTICS Blank= Standard DA= Advanced Diagnostics (audible) D= Advanced Diagnostics (non-audible) NEX= NEXUS® wired * NEXRF= NEXUS® wireless* HOUSING # OF HEADS 4X= Wet/ Damp Locations Blank= 0 heads* 2= Two heads * A remote load must be connected * Consult your sales representative Example: WWSVX12N1RD4X2LGCW4 56 LAMP TYPE/ WATTAGE LA= 6V-4W, MR16 LED LG= 12V-4W, MR16 LED LI= 12V-5W, MR16 LED LJ= 12V-6W, MR16 LED MI= 6V-6W, MR16 MK= 12V-12W, MR16 OPTIONS Blank= No options CW4= Cold weather (-40°F/-40°C)* FA= Flasher (fire alarm activated) F/B= Flasher/buzzer (AC power failure)** FL= Flasher (AC power failure) -208V= 208VAC, 60Hz input -240V= 240VAC, 60Hz input -208V50HZ= 208VAC, 50Hz input -CM= Canopy pendant mount * Single face only ** Not available with “D or DA” diagnostics TYPE: CATALOG #: NEMA-4X SPEC GRADE NOTES: Survive-All™ SVX Exit Series NEMA-4X Rated and UL Listed for Wet and Damp Locations Features Dimensions Dimensions are approximate and subject to change. Reliability 4-5/8” The Survive-All™ SVX Series has a 5-year full warranty. 3/4” 9-3/16” Rugged polyvinyl chloride body will not dent, peel, rust or corrode. The sealed faceplate is constructed of heavy duty, vandal-resistant polycarbonate and features an evenly illuminated legend. The fully gasketed faceplate is fastened with stainless steel tamper-resistant screws. Magnetically operated test switch. Models can be wall, end or ceiling mounted. Legend and chevron complies with UL and CSA requirements. INDUSTRIAL Unit Data - NEMA-4X* Rated 6-1/4” Survive-All™ SVX Series signs are unaffected by the vibrations, ambient temperature swings and typical power surges detrimental to standard exit light sources. 3-7/16” 3-7/8” 13-1/4” Double Face NEMA 4X* Rated. UL Listed. Listed for wet and Damp Locations 50°F to 104°F (+10°C/+40°C) Single Face * Nema-4X Certified for wall or ceiling mounting only High Performance Circuitry Accessories (order as a separate item) •S elf Contained – Batteries and circuitry located inside the exit housing. •C ontinuous self-diagnostic monitoring and monthly self testing. •F ully automatic charger is solid state. •A C, AC/DC and Self-Powered Models have universal, 2-wire input 120V to 277VAC 50/60 Hz. • Sealed, maintenance-free Nickel-Cadmium battery provides 90 minutes of emergency operation. •B attery recharges per UL924 requirements. •E ach unit comes standard with one tamper-proof driver bit. PART NUMBER DESCRIPTION Tamper-proof bit 690.0454-E Convert single to double face, red DFKR* Convert single face to double face, green DFKG* * Colors available AL-BK-WT Applications • Hosedown areas / car washes • Food processing / preparation facilities • Marine locations • Chemical plants • Schools and other public facilities • Parking garages • Food processing / preparation facilities • Transit platforms • Sports arenas / swimming pools • Security areas / prisons • Warehouse and cold storage facilities • Heavy industrial facilities Power Consumption (LED Exit Signs) Model AC Specs DC Specs AC-only 120 to 277VAC 1.2W – – AC/DC 120 to 277VAC 1.2W 6 to 24VDC Less than 1.5W Self-Powered 120 to 277VAC 3.7W Nickel-Cadmium Min. 90 minutes Note: Units installed outdoors must be in a shaded area (Lead-Calcium batteries) How to Order HOUSING COLOR BB= Black/black BW= Black/white BA= Black/aluminum GB= Gray/black GW= Gray/white GA= Gray/aluminum WB= White/black WW= White/white WA= White/aluminum SERIES SVX= AC only SVXN= Self-Powered Ni-Cd FACE 1= Single 2= Double LEGEND R= Red G= Green DIAGNOSTIC Blank= Standard D= Diagnostic (Self-Powered only) NEX= NEXUS® wired (consult your sales representative) NEXRF= NEXUS® wireless (consult your sales representative) Example: BBSVXN1RD4X-FA 57 HOUSING OPTIONS 4X= Wet/Damp Locations* Blank= No options 2CKT= Dual circuit (AC only)* CW= Cold weather (Self-Powered -4°F to 77°F / -20°C to 25°C – AC/DC -40°F to 77°F / -40°C to 25°C) DC= 6 to 48 VDC** FA= Fire alarm activated flasher* FL= Flasher only* FZ= Flasher/buzzer (Self-Powered only)* * NEMA 4X rated for wall or ceiling mount only *Not available with Nexus® option **Not available with Self-Power TYPE: CATALOG #: SPEC GRADE NEMA-4X Survive-All™ EF39 & EF40 Series EF39: NEMA-4X & NSF Certified EF40: Vandal Resistant Features INDUSTRIAL NOTES: Dimensions Dimensions are approximate and subject to change. •F ully gasketed with a selection of cast aluminum or polycarbonate back plate •C lear polycarbonate UV and impact resistant-lens • Choice of single or double lamp models •A vailable in 6, 12 and 24V models MR16 or LED •E asy lamp replacement •E F39 comes standard with tamper-proof screws and bit •N SF Certified for food processing plants •N EMA-4X Certified •E F39P and EF40P require mounting plate option when installed on surface mount junction box •C SA Certified to C22.2 No. 141 •S uitable for indoor/outdoor installation 7-1/8” 3-3/4” 4-5/8” Accessories (order as a separate item) PART NUMBER DESCRIPTION Additional special bit for tamper-proof screws 690.0454-E How to Order EF39 Series SERIES LAMP TYPE/WATTAGE EF39P= All polycarbonate single head NEMA-4X EF39PD= All polycarbonate double head NEMA-4X (MI)= 6V-6W, MR16 (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MS)= 24V-12W, MR16 (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LL)= 24V-4W, MR16 LED LAMP TYPE Blank= White -BK= Black -GY= Gray OPTION SM= Mounting plate Example: EF39P(LG)-BK SERIES LAMP TYPE/WATTAGE EF39= Die-Cast back plate single head NEMA-4X EF39D= Die-Cast back plate double head NEMA-4X (MI)= 6V-6W, MR16 (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MS)= 24V-12W , MR16 (MD)= 24V-20W, MR16 (MW)= 12V-20W, MR16-IR (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LL)= 24V-4W, MR16 LED (LJ)= 12V-6W, MR16 LED LAMP TYPE Blank= White -BK= Black -GY= Gray Example: EF39(LG)-BK How to Order EF40 Series SERIES EF40P= All polycarbonate single head for dry location EF40PD= All polycarbonate double head for dry location LAMP TYPE/WATTAGE (MI)= 6V-6W, MR16 (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MS)= 24V-12W, MR16 (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LL)= 24V-4W, MR16 LED LAMP TYPE Blank= White -BK= Black -GY= Gray OPTIONS Blank= No options T= Tamper proof screws SM= Mounting plate Example: EF40P(MK) SERIES EF40= Die-Cast back plate single head for dry location EF40D= Die-Cast back plate double head for dry location LAMP TYPE/WATTAGE (MI)= 6V-6W, MR16 (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MS)= 24V-12W , MR16 (MD)= 24V-20W, MR16 (MW)= 12V-20W, MR16-IR Example: EF40D(MD) 58 (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LL)= 24V-4W, MR16 LED (LJ)= 12V-6W, MR16 LED LAMP TYPE Blank= White -BK= Black -GY= Gray OPTIONS Blank= No options T= Tamper proof screws TYPE: CATALOG #: SPEC GRADE NOTES: HZM Series 6 and 12 Volt, Class I Division 2, Group A, B, C & D Features Dimensions Dimensions are approximate and subject to change. Conduit Fitting 14-3/8 8-3/4” 5” 15” 16” 6-7/8” Unit Rating Furnished standard with two 12W High Intensity Sealed Beam Halogen lamps. Sealed Maintenance-Free Battery Types Accessories (order as a separate item) PART NUMBER DESCRIPTION Wire Guard Lead-Calcium WG3-E D.C Voltage Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 3 hrs 4 hrs 24 18 10 6 Model Number 6 6HZM24-2 12 12HZM56-2 56 37 21 12 * National Electrical Code Specification. How to Order Note: Includes standard lamps. For standard units without options only order Series Number. SERIES 6HZM24= 6V-24W, Lead-Calcium 12HZM56= 12V-56W, Lead-Calcium # OF HEADS -0= No head -1= One head -2= Two heads LAMP TYPE XB= 6V-8W halogen sealed beam XD= 6V-12W halogen sealed beam XF= 12V-8W halogen sealed beam XG= 12V-12W halogen sealed beam Temperature code: T4A (max. 248ºF/120ºC) No other lamp type available Example: 6HZM24-2XB-H1 59 OPTIONS -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -H1= 120V Thermal Jacket Heater (recommended for ambient temperature) -H2= 277V Thermal Jacket Heater (recommended for ambient temperature) -TC= Shatter resistant teflon coated lens INDUSTRIAL •E ach unit comes with two (2) weather-resistant, impact-resistant, flameretardant thermoplastic EF-11 lamp heads with 12 watt high intensity sealed beam tungsten halogen lamps (standard) •T emperature code: T4A (max. 248ºF/120ºC) •W ater and corrosion-resistant cabinet is made of fiberglass-reinforced polyester. Industrial gray cabinet is fully gasketed around the cover. Battery compartment is vented with a breather vent designed to permit exhaust of battery gases without admitting external moisture or corrosives •A vailable with sealed, maintenance-free Lead-Calcium batteries •F ully automatic pulse charger offers 120/277VAC, 60Hz, 0.43/0.2 A, limited current temperature compensation, short circuit proof, reverse polarity protected, low voltage battery disconnect, brownout protection and standard solid state transfer feature •P AR36 sealed-beam halogen lamps (see lamp selection chart below) •S tandard Self-Diagnostic circuitry continuously monitors every critical function of the unit. If a problem occurs, a single fault indicator on the outside of the fixture flashes immediately. A detailed diagnostic display is located internally. The detailed display will further indicate the nature of the fault as either a battery fault, load fault or a charger fault •U L Listed. Complies with NEC, Life Safety Code and OSHA. The test switch and AC pilot light are explosion proof in design and exceed requirements for Class I, Division 2, Group A, B, C & D •3 -year full warranty, excluding lamps, pilot lights and fuses. TYPE: CATALOG #: SPEC GRADE NOTES: US Survive-All™ SVH Series Hazardous Location Battery Unit Dimensions Dimensions are approximate and subject to change. •E valuated to the UL 844 Standard for Class I Division 2, Groups A, B, C and D •A range of lamp ratings are available for different temperature codes •E valuated to the UL924 Standard • Certified for use in Damp and Wet locations. •A mbient temperature: 10… 40°C (50… 104°F) •A dvanced Diagnostics option available •L ead-Calcium batteries are sealed, maintenance-free, with up to 72W emergency power •C hoice of MR16 LED or halogen lamps, shielded by a clear polycarbonate cover •T wo MR16 LED lamps illuminate up to a 60 ft path of egress •R emote load capacity: illuminate up to a 420 ft path of egress with LED remote heads •P olyvinyl chloride frame, with built-in gasket to prevent water infiltration •H eavy-duty 1/8-inch thick aluminum back plate with keyholes for secure wallmount installation •B uilt-in microcontroller-based battery charger and self-test/ self-diagnostic circuitry • 3/4-inch electrical conduit entry on both sides and at the top 3-1/2” 14-1/2” 6-1/4” 13-3/4” 12-5/8” INDUSTRIAL Features Temperature Codes Lamp Rating Temperature Code Max. Temperature Replacement Part # 6V-4W T4A 120°C 580.0097 6V-10W T3C 160°C 580.0079 12V-4W T4A 120°C 580.0080 12V-5W T4A 120°C 580.0104 12V-12W T3A 180°C 580.0080 12V-20W-H T2D 215°C 580.0068 Note: Use qualified replacement lamps to avoid risk of over-heating Power Consumption Model SVH18 12SVH36 120/277VAC 12SVH60 Wattage Capacity AC Specs 12SVH72 1-1/2 hrs 2 hrs 3 hrs 4 hrs 8 hrs 0.17 / 0.09 Amp 18 12 9 – – 0.30 / 0.15 Amp 36 27 18 14 – 0.30 / 0.15 Amp 60 45 30 24 12 0.30 / 0.15 Amp 72 54 36 28 14 How to Order COLOR G= Gray VOLTAGE AND POWER SVH18M= 6V-18W, Lead-Calcium 12SVH36M= 12V-36W, Lead-Calcium 12SVH60M= 12V-60W, Lead-Calcium 12SVH72M= 12V-72W, Lead-Calcium # OF HEADS -2= Two heads -0= No heads LAMPS LA= 6V-4W, 2 X MR16 LED LG= 12V-4W, 2 X MR16 LED LI= 12V-5W, 2 X MR16 LED MK= 12V-12W, MR16 MW= 12V-20W, MR16-IR high-output OPTIONS -DA= Advanced Diagnostics (audible)* -D= Advanced Diagnostics (non-audible)* -D3= Time delay (15 minutes) -NEX= NEXUS® wired (consult your sales representative)* -NEXRF= NEXUS® wireless (consult your sales representative)* (12SVH only) * Minimum lamp load required: 20% of unit capacity Example: G12SVH72M-2MK-DA 60 TYPE: CATALOG #: SPEC GRADE NOTES: US Survive-All SVXH Series ™ Hazardous Location Combination and Emergency Battery Unit Features Dimensions Dimensions are approximate and subject to change. 13-3/4” 6-1/4” 12-5/8” Temperature Codes Lamp Rating Accessories (order as a separate item) PART NUMBER DESCRIPTION Additional special bit for tamper-proof screws 3-1/2” 14-1/2” INDUSTRIAL •E xit sign module is illuminated by long-life, energy-efficient LEDs. Fully field adjustable lamp head assembly comes standard with a selection of two (2) MR16 halogen lamps for optimum illumination over the path of egress. Lamps are shielded by a cast aluminum housing and a polycarbonate cover •R ugged PVC body will not dent, peel or corrode. The sealed faceplate has a heavy-duty, vandal-resistant polycarbonate cover and is fastened with stainless steel tamper-resistant screws. The polyvinyl chloride frame has a built-in gasket to prevent water infiltration. The heavy-duty 1/8” thick aluminum back plate has keyholes for secure wall mount installation •A vailable with sealed, maintenance-free Nickel-Cadmium, or Nickel-Metal Hydride batteries •F ully automatic pulse charger offers 120/277VAC, 60Hz, current limiting temperature compensation, short circuit proof, low voltage battery disconnect, brownout protection and standard solid state transfer feature. The test switch is magnetically operated •A dvanced Diagnostic circuitry is standard on all Self-Powered models. This circuitry is programmed to ensure the combination unit’s readiness and reliability by continuously monitoring every critical function of the unit. If a problem occurs, a single “Service Required” indicator illuminates immediately. A detailed diagnostic display that will further indicate the nature of the fault is located on the inside of the exit sign, out of sight from the general public. The self test will test the unit for a minimum of 30 seconds every 30 days, 30 minutes every 60 days and 90 minutes annually •D esigned for wall-mount installation only with a 1/2” electrical conduit entry on both sides and at the top. •E valuated to UL 924 standard and to UL 844 standard for hazardous locations: Class I Division 2, Groups A, B, C and D. A range of lamp ratings are available for different temperature codes •5 -year full warranty, excluding lamps and fuses 690.0454-E Temperatude Code Max. Temperature Replacement Part # 6V-10W T3C 320°F/160°C 580.0079-E 12V-12W T3A 356°F/180°C 580.0080-E 12V-20W T2D 419°F/215°C 580.0068-E 6V-4W LED T4A 248°F/120°C 580.0097-E 12V-4W LED T4A 248°F/120°C 580.0093-E 12V-5W LED T4A 248°F/120°C 580.0104-E Note: Use qualified replacement lamps to avoid risk of over-heating Applications • Manufacturing Plants • Chemical plants • Paint Shops • Gas Stations Power Consumption Chart • Moisture, Dirt or Dust Concerns • Oil Refineries • Wet or Corrosive Conditions Model SVXH GG= Gray/gray Maximum Current Power 120/277VAC 0.15/0.07A 16W Stand-by Current Unit Rating* Power 11/2 hrs 2 hrs 3 hrs 4 hrs 0.09/0.03A 8W 20 15 – – SVXH12N 120/277VAC 0.30/0.08A 29W 0.13/0.05A 10W 24 18 12 – SVXH12H 120/277VAC 0.30/0.08A 29W 0.13/0.05A 10W 40 30 20 12 * Watts to 87-1/2% of rated battery voltage How to Order HOUSING/FACE COLOR AC Input SERIES/CAPACITY SVXH= 6V-20W, Ni-Cd SVXH12N= 12V-24W, Ni-Cd SVXH12H= 12V-40W, NiMH LEGEND COLOR R= Red G= Green DIAGNOSTICS # OF HEADS LAMP TYPE/WATTAGE* DA= Advanced Diagnostics (audible) D= Advanced Diagnostics (non-audible) NEX= NEXUS® wired* NEXRF= NEXUS® wireless* Blank= 0 head* 2= Two heads LA= 6V-4W, MR16 LED LG= 12V-4W, MR16 LED LI= 12V-5W, MR16 LED MK= 12V-12W MR16 MJ= 6V-10W MR16 MW= 12V-20W MR16 IR high output * Consult your sales representative * A remote load must be connected * No other lamp option available Example: GGSVXHRD2MJ 61 TYPE: CATALOG #: SPEC GRADE NOTES: US Survive-All™ SVX-HZ Series Hazardous Location Exit Sign INDUSTRIAL Features Dimensions Dimensions are approximate and subject to change. •E nergy efficient: consumes less than 2.5 watts in any configuration. Exit sign illuminated by long-life, energy-efficient LEDs. •S ingle face heavy-duty 1/8” thick aluminum back plate. Polyvinyl chloride frame, with built-in gasket to prevent water infiltration. Will not dent, peel, rust or corrode. The sealed, heavy-duty, vandal-resistant polycarbonate faceplate features an evenly illuminated legend. The fully gasketed faceplate is fastened with stainless steel tamper-resistant screws. Self contained; batteries and circuitry are located inside the exit housing. •A vailable with sealed, maintenance-free Nickel-Cadmium batteries that provide 90 minutes of emergency operation. Batteries recharge per UL924 requirements. •A C and Self-Powered models have universal, 2-wire input 120V to 277VAC 50/60Hz. •T amper-resistant, hermetically sealed magnetic test switch for Self-Powered models. •D iagnostic / Self Test circuitry is standard on all Self-Powered models. This circuitry is programmed to ensure the exit sign’s readiness and reliability by continuously monitoring every critical function of the unit. If a problem occurs, a single “service required” indicator illuminates immediately. A detailed diagnostic display that will further indicate the nature of the fault is located on the inside of the exit sign, out of sight from the general public. The self test will test the unit for a minimum of 30 seconds every 30 days, 30 minutes every 60 days and 90 minutes annually. •C an be wall, end or ceiling mounted. Comes standard with an industrialgrade, Die-Cast aluminum electrical box. 1/2” electrical conduit entry on both sides and at the top. Each unit comes standard with one tamper-proof driver bit. •L egend and chevron comply with UL requirements. Evaluated to the UL 844 standard for Class I Division 2, Groups A, B, C and D, Temperature Code: T6 (maximum 185°F/85°C). Evaluated to UL 924 and UL1598 standards. Suitable for cold-weather: -4°F/-20°C (Self-Powered model, “CW” option) and -40°F/-40°C (AC only). •5 -year full warranty 4-3/4” 2-1/4” 4-3/8” 9-1/4” 13-1/4” 3-1/2” Power Consumption Model AC Specs DC Specs AC-only red 120 to 277VAC Less than 2W – – AC-only green 120 to 277VAC Less than 1.5W – – Self-Powered red 120 to 277VAC Less than 2W Self-Powered green 120 to 277VAC Less than 2.5W Ni-Cd battery Min. 90 minutes Ni-Cd battery Min. 90 minutes * Note: Cold-weather option does not consume additional power Accessories (order as a separate item) PART NUMBER DESCRIPTION Tamper-Proof Bit (extra) 690.0454-E Convert single to double face, red* DFKR-GY Convert single face to double face, green* DFKG-GY * In the field Applications • Manufacturing Plants • Chemical plants • Paint Shops • Gas Stations • Moisture, Dirt or Dust Concerns • Oil Refineries • Wet or Corrosive Conditions How to Order COLOR OF BODY/FACE GG= Gray/gray SERIES SVXHZ= AC only SVXNHZ= Self-Powered Ni-Cd FACE 1= Single (ceiling/ wall mount) 2= Double (ceiling mount only) LEGEND R= Red G= Green Example: GGSVXNHZ2R-DCW 62 DIAGNOSTIC -D= Diagnostic (Self-Powered only) -NEX= NEXUS® wired (consult your sales representative) OPTIONS Blank= AC only CW= Cold weather (-4°F/-20°C for Self-Powered and -40°F/ -40°C for AC only) TYPE: CATALOG #: SPEC GRADE NOTES: US Survive-All™ EF41 Series Remote Fixture for Hazardous Locations Features Dimensions Dimensions are approximate and subject to change. •A vailable with single or double lamp heads with high-efficiency MR16 halogen lamps of 10W, 12W or 20W (see How to Order information) and MR16 high-output LEDs (4W, 5W and 6W) •D ie-Cast aluminum back plate with gasket. Clear polycarbonate cover, UV and impact resistant • Input voltage: 6V, 12V, 24V or 120V •E asy installation on a 4” octagonal box (included). Comes standard with tamper-proof screws and bit •E valuated to UL 844 Standard for Class I Division 2, Groups A, B, C and D. Temperature Codes: T3B (10W and 12W MR16 lamps) and T2C (20W MR16 lamps) and T4A and T5 MR16 LED. • Extreme operational temperature range: -40ºF to +104ºF (-40ºC to +40ºC) • Indoor use •F ully adjustable tool-less aiming swivel • Tool-less easy lamp replacement •S urface mount •C onduit entry 1/2” NPT 5-7/8” Remote Fixture Junction box 3-3/4” 2-1/8” 4-5/8” 4” Junction Box Lamp Selection Chart and Temperature Code Lamp Suffix MJ Voltage 6 Wattage 10 Lumens 74 Replacement # 580.0079-E Temperature Code T3B Max Temperature 165°C MK 12 12 80 580.0080-E T3B 165°C MW 12 20-H 400 580.0068-E T2C 230°C MS 24 12 82 580.0070-E T3B 165°C MD 24 20 240 580.0077-E T2C 230°C MT 120 20 100 580.0065-E T2C 230°C LA 6 4 200 580.0097-E T4A 120°C LG 12 4 220 580.0093-E T5 100°C LI 12 5 340 580.0104-E T4A 120°C LJ 12 6 540 580.0106-E T4 135°C LL 24 4 220 580.0098-E T5 100°C LW 120 4 230 580.0113-E T4A 120°C How to Order SERIES EF41= Single EF41D= Double LAMP TYPE/WATTAGE (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LJ)= 12V-6W, MR16 LED (LL)= 24V-4W, MR16 LED (LW)= 120V-4W, MR16 LED (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MW)= 12V-20W, MR16 IR high output (MS)= 24V-12W, MR16 (MD)= 24V-20W, MR16 (MT)= 120 VAC/VDC-20W MR16 (GU10) Example: EF41(MJ)-GY 63 COLOR -GY= Gray INDUSTRIAL 7-1/8” TYPE: CATALOG #: SPEC GRADE NOTES: IL Series 6, 12 & 24 Volt Heavy Duty Industrial Emergency Power Unit Dimensions Dimensions are approximate and subject to change. •E ach unit comes with two (2) impact resistant, flame retardant thermoplastic EF-18 lamp heads with 9 watt high intensity incandescent lamps (standard). •A ll 20 gauge in steel construction ASA61 gray baked enamel finish. •A vailable with sealed, maintenance-free Nickel-Cadmium, Long Life Lead, Lead-Calcium (Free Electrolyte) or Lead-Calcium batteries. •P ulsePlus Charger circuitry offers 120/277 volt input 60 Hz, 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lockout (automatic battery connect). •P rovision for mounting to any standard 4” octagonal electrical box. The hinged and lockable front door allows easy access for maintenance and provides security against unauthorized access and vandalism. •U L Listed. Complies with NEC, Life Safety Code and OSHA. Approved for use in the Commonwealth of Pennsylvania. •3 -year full warranty, excluding lamps and fuses. 10-3/8” Knockouts for 1/2” Conduit: -2 each side, 1 rear (7/8” Dia) knockout 16-1/2” INDUSTRIAL Features 16-1/8” 4-3/4” Accessories (order as a separate item) SUFFIX DESCRIPTION Unit Rating Chart Mounting bracket B2 Mounting shelves (gray) MP3-GY Wire Guard WG3-E Furnished standard with two 9 watt High Intensity Incandescent lamps. UNIT EQUIPMENT - NO REMOTE CAPABILITY Sealed Maintenance-Free Battery Types Nickel-Cadmium Long Life Lead Lead-Calcium D.C. Voltage 6 6 6 Model Number ILSC18-2 ILSE18-2 ILSM18-2 Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 4 hrs 8 hrs 18 12 6 – 18 11 6 – 18 12 7 – # of Load Fuses – – – UNIT EQUIPMENT - WITH REMOTE CAPABILITY Nickel-Cadmium Long Life Lead Lead-Calcium (Immobilized Electrolyte) Lead-Calcium 6 12 12 24 24 6 6 6 6 6 12 12 12 12 24 24 6 6 6 6 6 6 6 12 12 12 24 ILSC25-2 12ILSC36-2 12ILSC50-2 24ILSC72-2 24ILSC100-2 ILSE27-2 ILSE36-2 ILSE54-2 ILSE80-2 ILSE110-2 12ILSE36-2 12ILSE54-2 12ILSE72-2 12ILSE110-2 24ILSE72-2 24ILSE110-2 ILC87-2 ILC100-2 ILSM27-2 ILSM36-2 ILSM54-2 ILSM81-2 ILSM110-2 12ILSM36-2 12ILSM54-2 12ILSM110-2 24ILSM110-2 25 36 50 72 100 27 36 54 80 110 36 54 72 110 72 110 87 100 27 36 54 81 110 36 54 110 110 * National Electrical Code Specification 64 18 21 36 42 73 16 24 36 65 72 24 37 48 74 48 74 70 77 18 25 37 54 72 25 37 72 72 9 12 18 24 36 10 13 20 35 40 13 21 26 43 26 43 41 47 10 14 21 36 40 14 21 40 40 – 6 10 12 20 6 7 11 19 24 7 10 14 21 14 21 24 24 6 7 12 18 24 7 12 24 24 – 1 1 2 2 – – – – – 1 1 2 2 2 2 – – – – – – – 1 1 2 2 TYPE: CATALOG #: SPEC GRADE NOTES: IL Series 6, 12 & 24 Volt Heavy Duty Industrial Emergency Power Unit How to Order SERIES/VOLTAGE UNIT CAPACITY 87= 87W Lead-Calcium 100= 100W Lead-Calcium ILS= 6V C18= 18W Ni-Cd C25= 25W Ni-Cd E18= 18W Long Life Lead E27= 27W Long Life Lead E36= 36W Long Life Lead E50= 50W Long Life Lead E80= 80W Long Life Lead E110= 110W Long Life Lead M18= 18W Lead-Calcium M27= 27W Lead-Calcium M36= 36W Lead-Calcium M54= 54W Lead-Calcium M81= 81W Lead-Calcium M110= 110W Lead-Calcium 12ILS= 12V C36= 36W Ni-Cd C50= 50W Ni-Cd E36= 36W Long Life Lead E54= 54W Long Life Lead E80= 80W Long Life Lead E110= 110W Long Life Lead M36= 36W Lead-Calcium M54= 54W Lead-Calcium M110= 110W Lead-Calcium 24ILS= 24V C100= 100W Ni-Cd E72= 72W Long Life Lead E110= 110W Long Life Lead M110= 110W Lead-Calcium C72= 72W Ni-Cd # OF HEADS -0= No head -1= One head -2= Two heads -3= Three heads LAMP OPTIONS Blank= 6V-9W, 12V-9W, 24V-9W incandescent wedge base H_= Halogen bi-pin Z_= Tungsten incandescent U_= Tungsten sealed beam X_= Halogen sealed beam -AD= Advanced Diagnostics (audible)* -ADNA= Advanced Diagnostics (non-audible)* NEX= NEXUS® wired (consult your sales representative)* NEXRF= NEXUS® wireless (consult your sales representative)* -A= Ammeter -V= Voltmeter -CP= Cord and plug 120V only -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -E= Cord and plug 277V** -OW= Off-white cabinet and heads NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 * Minimum lamp load required: 20% of unit capacity Option not available with 24V-100W Ni-Cd units ** Standard cord is 3 ft Example: ILC87-2HB-A 65 INDUSTRIAL ILC= 6V TYPE: CATALOG #: SPEC GRADE NOTES: KS Steel Series 6, 12, 24 Volt Harsh Environment Enclosure Power Unit INDUSTRIAL Features Dimensions Dimensions are approximate and subject to change. •U p to three weather-resistant thermoplastic heads can be mounted on the enclosure. Each unit comes with two (2) 9W high intensity incandescent lamps (standard) •C onstructed of 14 gauge steel with a fully gasketed hinged door and separate battery compartment. Gray baked epoxy enamel finish •A vailable with sealed, maintenance-free Nickel-Cadmium, Long Life Lead, Lead-Calcium (Free Electrolyte), or Lead-Calcium batteries •P ulsePlus Charger circuitry offers 120/277V input 60Hz, 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lockout (automatic battery connect) •U L Listed. Complies with NEC, Life Safety Code and OSHA •3 -year full warranty, excluding lamps and fuses 19-3/8” 12-1/8” 13-1/2” 13-1/2” 13-7/8” 6” Unit Rating Chart Furnished standard with two 9 watt High Intensity Incandescent lamps. Sealed Maintenance-Free Battery Types KSC18-2 Watts to 87-1/2% of rated battery voltage* 11⁄2 hrs 2 hrs 3 hrs 4 hrs 18 12 10 7 KSE18-2 18 11 8 6 D.C. Voltage Nickel-Cadmium 6 Long Life Lead 6 Model Number UNIT EQUIPMENT - WITH REMOTE CAPABILITY Nickel-Cadmium Long Life Lead Lead-Calcium (Immobilized Electrolyte) Lead-Calcium 6 KSC25-2 25 18 9 5 12 12KSC36-2 36 21 21 6 12 12KSC50-2 50 36 18 10 12 12KSC100-2 100 73 37 20 24 24KSC100-2 100 73 37 20 6 KSE27-2 27 19 10 5 6 KSE36-2 36 24 13 7 6 KSE54-2 54 36 20 11 6 KSE80-2 80 65 35 19 6 KSE110-2 110 74 43 21 6 KSE160-2 160 130 70 38 12 12KSE36-2 36 24 13 7 12 12KSE54-2 54 37 21 10 12 12KSE110-2 110 74 43 21 12 12KSE160-2 160 130 70 38 24 24KSE110-2 110 74 43 21 6 KC87-2 87 70 41 24 6 KC100-2 100 77 47 24 6 KC175-2 175 140 85 48 12 12KC175-2 175 140 85 48 6 KSM27-2 27 18 10 6 6 KSM54-2 54 37 21 12 6 KSM81-2 81 54 30 18 6 KSM110-2 110 72 40 24 12 12KSM54-2 54 37 21 12 12 12KSM110-2 110 72 40 24 24 24KSM110-2 110 72 40 24 *National Electrical Code Specification 66 TYPE: CATALOG #: SPEC GRADE NOTES: KS Steel Series 6, 12, 24 Volt Harsh Environment Enclosure Power Unit How to Order SERIES/VOLTAGE UNIT CAPACITY C18= 6V-18W Ni-Cd C25= 6V-25W Ni-Cd E18= 6V-18W Long Life Lead E27= 6V-27W Long Life Lead E36= 6V-36W Long Life Lead E54= 6V-54W Long Life Lead E80= 6V-80W Long Life Lead E110= 6V-110W Long Life Lead E160= 6V-160W Long Life Lead M27= 6V-27W Lead-Acid M54= 6V-54W Lead-Acid M81= 6V-81W Lead-Acid M110= 6V-110W Lead-Acid 12KS= 12V C36= 12V-36W Ni-Cd C50= 12V-50W Ni-Cd C100= 12V-100W Ni-Cd E36= 12V-36W Long Life Lead E54= 12V-36W Long Life Lead E110= 12V-110W Long Life Lead E160= 12V-160W Long Life Lead M54= 12V-54W Lead-Acid M110= 12V-110W Lead-Acid 24KS= 24V C100= 24V-100W Ni-Cd E110= 24V-110W Long Life Lead M110= 24V-110W Lead-Calcium K= 6V C87= 6V-87W Lead-Calcium (free electrolytes) C100= 6V-100W Lead-Calcium (free electrolytes) C175= 6V-175W Lead-Calcium (free electrolytes) 12K= 12V C175-2= 12V-175W Lead-Calcium (free electrolytes) # OF HEADS LAMP -0= No head -1= 1 head -2= 2 heads Blank= 6V-9W, 12V-9W, 24V-9W incandescent wedge base H_= Halogen bi-pin I_= Incandescent DC-bayonet U_= Incandescent sealed-beam X_= Halogen sealed-beam Z_= Incandescent wedge NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: KSC18-2HB-AD 67 OPTIONS -AD= Advanced Diagnostics (audible)* -ADNA= Advanced Diagnostics (non-audible)* NEX= Nexus® wired (consult your sales representative)* NEXRF= Nexus® wireless (consult your sales representative)* -V= Voltmeter -A= Ammeter -TD= Time Delay -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -K= Lamp Disconnect Switch -CP= Cord and plug 120V for fiberglass enclosure** -E= Cord and plug 277V** -S= Photometric test switch -VR= Tamper proof screws -FL= Large cabinet -TM= Top mounted heads -208V= Input 208VAC, 50/60Hz * Minimum lamp load required: 20% of unit capacity Option not available on 24V-100W Ni-Cd units ** Standard cord is 3 ft. INDUSTRIAL KS= 6V TYPE: CATALOG #: SPEC GRADE NOTES: KS Series 6, 12 & 24 Volt High Impact Enclosure Power Unit Dimensions Dimensions are approximate and subject to change. •E ach unit comes with two (2) 9W high intensity incandescent lamps (standard). •B oth the “S” and “L” enclosure are corrosion resistant. Both include separate battery compartments, fully gasketed door and stainless steel hardware. The “S” enclosure is constructed of high impact thermoplastic and the “L” enclosure is constructed of fiberglass and is NEMA 3R •A vailable with sealed, maintenance-free Nickel-Cadmium, Long Life Lead, Lead-Calcium (Free Electrolyte) or Lead-Calcium batteries. •P ulsePlus Charger circuitry offers 120/277 volt input 60 Hz, 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lockout (automatic battery connect). •U L Listed. Complies with NEC, Life Safety Code and OSHA. •3 -year full warranty, excluding lamps and fuses. 10-3/8” Small “S” Enclosure High Impact Thermoplastic Construction 8” 11-5/8” SUFFIX DESCRIPTION WG3-E Wire Guard (Large enclosure) WG4-E 5” Large “L” Enclosure Fiberglass Construction NEMA-3R 16-3/4” Accessories (order as a separate item) Wire Guard (Small enclosure) 13” 13-3/8” 23” 17-1/2” INDUSTRIAL Features 12” 15-5/8” 6-1/4” Unit Rating UNIT EQUIPMENT - NO REMOTE CAPABILITY Nickel-Cadmium 6 KSC18-2-F Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 3 hrs 4 hrs 18 12 10 7 Long Life Lead 6 KSE18-2-F 18 Sealed Maintenance-Free Battery Types D.C. Voltage Model Number Enclosure Size S 11 8 6 S 18 21 36 73 73 19 24 36 65 74 130 24 37 74 130 74 70 77 140 140 18 37 54 72 37 72 72 9 21 18 37 37 10 13 20 35 43 70 13 21 43 70 43 41 47 82 85 10 21 30 40 21 40 40 5 6 10 20 20 5 7 11 19 21 38 7 10 21 38 21 24 24 48 48 6 12 18 24 12 24 24 S S S S S S S S S S L S S S L S S L L L S S S S S S S UNIT EQUIPMENT - WITH REMOTE CAPABILITY Nickel-Cadmium Long Life Lead Lead-Calcium (Free Electrolyte) Lead-Calcium 6 12 12 12 24 6 6 6 6 6 6 12 12 12 12 24 6 6 6 12 6 6 6 6 12 12 24 KSC25-2-F 12KSC36-2-F 12KSC50-2-F 12KSC100-2-F 24KSC100-2-F KSE27-2-F KSE36-2-F KSE54-2-F KSE80-2-F KSE110-2-F KSE160-2-F 12KSE36-2-F 12KSE54-2-F 12KSE110-2-F 12KSE160-2-F 24KSE110-2-F KC87-2-F KC100-2-F KC175-2-F 12KC175-2-F KSM27-2-F KSM54-2-F KSM81-2-F KSM110-2-F 12KSM54-2-F 12KSM110-2-F 24KSM110-2-F 25 36 50 100 100 27 36 54 80 110 160 36 54 110 160 110 87 100 175 175 27 54 81 110 54 110 110 *National Electrical Code Specification 68 TYPE: CATALOG #: NEMA-3R SPEC GRADE NOTES: KS Series 6, 12 & 24 Volt High Impact Enclosure Power Unit How to Order SERIES/VOLTAGE UNIT CAPACITY C18= 6V-18W Ni-Cd C25= 6V-25W Ni-Cd E18= 6V-18W Long Life Lead E27= 6V-27W Long Life Lead E36= 6V-36W Long Life Lead E54= 6V-54W Long Life Lead E80= 6V-80W Long Life Lead E110= 6V-110W Long Life Lead E160= 6V-160W Long Life Lead M27= 6V-27W Lead-Acid M54= 6V-54W Lead-Acid M81= 6V-81W Lead-Acid M110= 6V-110W Lead-Acid 12KS= 12V C36= 12V-36W Ni-Cd C50= 12V-50W Ni-Cd C100= 12V-100W Ni-Cd E36= 12V-36W Long Life Lead E54= 12V-36W Long Life Lead E110= 12V-110W Long Life Lead E160= 12V-160W Long Life Lead M54= 12V-54W Lead-Acid M110= 12V-110W Lead-Acid 24KS= 24V C100= 24V-100W Ni-Cd E110= 24V-110W Long Life Lead M110= 24V-110W Lead-Calcium K= 6V C87-2-F= 6V-87W Lead-Calcium (free electrolytes) C100-2-F= 6V-100W Lead-Calcium (free electrolytes) C175-2-F= 6V-175W Lead-Calcium (free electrolytes) 12K= 12V C175-2= 12V-175W Lead-Calcium (free electrolytes) # OF HEADS -0= No head -1= 1 head -2= 2 heads LAMP Blank= 6V-9W, 12V-9W, 24V-9W incandescent wedge base H_= Halogen bi-pin I_= Incandescent DC-bayonet U_= Incandescent sealed-beam X_= Halogen sealedbeam Z_= Incandescent wedge NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: KS18-2HB-AD 69 ENCLOSURE TYPE F= Fiber glass or high impact thermoplastic OPTIONS -AD= Advanced Diagnostics (audible)* -ADNA= Advanced Diagnostics (non-audible)* NEX= Nexus® wired (consult your sales representative)* NEXRF= Nexus® wireless (consult your sales representative)* -V= Voltmeter -A= Ammeter -TD= Time Delay -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes)** -K= Disconnect Switch -CP= Cord and plug 120V for fiberglass enclosure** -E= Cord and plug 277V** -S= Photometric test switch -VR= Tamper-proof screws -FL= Large cabinet -TM= Top mounted heads -208V= Input 208VAC, 50/60Hz * Minimum lamp load required: 20% of unit capacity Not available on 24V-100W Ni-Cd units ** Standard cord is 3 ft. INDUSTRIAL KS= 6V TYPE: CATALOG #: SPEC GRADE NOTES: EXC Series 6 and 12 Volt – Class I, Div. 1 & 2, Groups C & D and Class II, Div. 1 & 2, Groups E, F & G Power Unit INDUSTRIAL Features Spinoff Gasketed Cover •A llows mounting up to 3 hazardous area fixtures directly on the power unit or remotely. •C orrosion-resistant, copper-free cast aluminum construction. A weatherproof gasketed spinoff cover, UL listed stainless steel vent/drain and silicone conformal coating on the circuit board protect the electronics against humidity. Comes standard with epoxy finish for added corrosion protection in harsh environments. •A vailable with sealed, maintenance-free Nickel-Cadmium batteries. •C harger offers 120/277 VAC, 60 Hz, 0.3/0.15A, 36 watt (other inputs available), fused DC output circuit, AC pilot light supervision, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection, lockout (automatic battery connect), solid state, current limited, constant current short circuit proof and reverse polarity protection. •M eets hazardous location requirements: Class I Division 1 & 2 (Groups C & D), Class II Division 1 & 2 (Groups E, F & G). •3 -year full warranty, excluding lamps, pilot lights, and fuses. 3/4” NPT Conduit Entrance Fixtures Copper-Free Cast Aluminum Stainless Steel Vent/Drain Combination Test Switch & Pilot Light Dimensions Dimensions are approximate and subject to change. The EXC Series may be supplied with 1 or 2 hazardous fixtures mounted directly on the power unit and/or remotely as the application dictates (for remote fixtures, consult hazardous area fixture data sheet). Housing: 12” X 12” X 91⁄2” (4) Mounting Lugs: 10” and 131⁄2” on center Lamp Fixtures (EP Series) See page 72: Fully directional U.L. listed copper-free cast aluminum construction, swivel-mounted, Pyrex® lens, complete with either 9, 18, or 25 watt HIT lamps (halogen optional). Available with optional guard or reflectors. Pyrex® is a registered trademark of Corning Glass. Overall dimensions (including fixtures): 38” X 38” X 10” Note: Dimensions are approximate and are subject to change. Exit Fixtures (XP Series) See page 73: Mounted to the power unit, these exit signs are supplied standard with our unique integral transfer switch (TS) and utilize either a 6V-15W XX6 lamp or 12V-25W XX12 lamp. This enables the exit to operate in both the normal AC mode as well as DC mode. The exit sign consists of an EP fixture coupled with a heavy duty steel, baked enamel finish exit shroud with ample downlight. Supplied standard as a single face sign, red stencil faceplate; double face and green stencil also available. For other legends, please consult your sales representative. Unit Rating UNIT EQUIPMENT - WITH REMOTE CAPABILITY Sealed Maintenance-Free Battery Types Nickel-Cadmium D.C. Voltage Model Number 6 EXC1 6 EXC2 25 18 9 – 6 EXC3 36 21 12 6 6 EXC5 50 36 18 10 12 1EXC3 36 21 12 6 12 1EXC5 50 36 18 10 12 1EXC7 72 42 24 12 *National Electrical Code Specification 70 Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 4 hrs 8 hrs 18 12 – – TYPE: CATALOG #: SPEC GRADE NOTES: EXC Series 6 and 12 Volt – Class I, Div. 1 & 2, Groups C & D And Class II, Div. 1 & 2, Groups E, F & G Power Unit Standard Configurations for EXC Series UNIT CATALOG NUMBER DESCRIPTION 12 volt, 50 watt self-contained hazardous area emergency lighting power unit complete with battery and charger. (No heads) 1EXC5-TS 12 volt, 50 watt self-contained hazardous area emergency lighting power unit complete with battery, charger and transfer switch. (No heads) 1EXC5-1IG 12 volt, 50 watt, single head unit with 12 volt, 25 watt HIT lamp. (One head) 1EXC5-1IG-TS 12 volt, 50 watt, single head unit with built-in transfer switch and 12 volt, 25 watt HIT lamp. (One head) EXC3-2IB 6 volt, 36 watt, self-contained hazardous area emergency lighting power units complete with battery and charger. Fixture supplied with one (IB) 18 watt HIT lamp (Two heads) EXC5-2IB-TS 6 volt, 50 watt, double head unit with built-in transfer switch and 12 volt, 25 watt HIT lamp (Two heads) EXC2-T1SR 6 volt, 15 watt, self-contained unit with integral low voltage transfer circuit (TS) to operate exit lamp in both normal and emergency modes. Suggested catalog number shown indicates single face exit with red stencil faceplate. For green, substitute G for R. For double face, substitute D for S. (One Exit sign) EXC-1HD-T1SR 6 volt, 50 watt unit. In addition to the exit lamp which operates in both normal and emergency modes, emergency lighting can be achieved with (1) additional emergency lighting head. (Example: HD = 6V-12W). (One head & one Exit sign) (Remote Capability) Note: Above units are supplied with appropriate wattage (HIT) High Intensity Tungsten lamps (unless otherwise specified). Alternate wattages lamps or halogen lamps may be substituted as required. Exit provided with 25 watt lamps only. How to Order The EXC Series is available with a wide variety of fixtures, mountings, voltages, etc. To make your selection easier, we have listed the standard configurations in the chart above. When ordering exit fixtures, additional to the basic catalog number, you must specify single or double face and color of faceplate. Insert these suffix letters at the end of model number. SERIES EXC= 6V 1EXC= 12V CAPACITY 1= 18W (6V only) 2= 25W (6V only) 3= 36W (6V, 12V) 5= 50W (6V, 12V) 7= 72W (12V only) NO. OF FIXTURES -0= No remote -1= One remote -2= Two remotes LAMPS* EXIT SIGN* Blank= No lamps HB= 6V-8W bi-pin halogen HD= 6V-12W bi-pin halogen HF= 12V-8W bi-pin halogen HG= 12V-12W bi-pin halogen Blank= No exits -T1SR= Single face red -T1SG= Single face green -T1DR= Double face red -T1DG= Double face green * Lamps for emergency lights * Exit lamp included Example: 1EXC7-1HG-T1SR-D1 71 OPTIONS Blank= No options TS= Transfer switch -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -RD= Dome reflector -RA= Angle reflector -GXP= Aluminum guard INDUSTRIAL 1EXC5-0 TYPE: EFEPC= Ceiling mount – 11 lbs. CATALOG #: SPEC GRADE NOTES: EFEPP= Pendant Mount with hanger box & pendant – 14 lbs EFEP Series Remote Explosion-Proof Lighting Fixtures INDUSTRIAL Features •A vailable with 6, 12 and 24V lamps for DC operation or 120V AC fixtures. •M anufactured of heavy cast aluminum with an epoxy finish and a Pyrex® lens. All attached hardware has been designed for explosion-proof applications. •D esigned for mounting in locations that are remote from the power source. If the power source is installed outside hazardous areas, the length of connection wires should be carefully considered to ensure that the voltage of the emergency power unit and the wire size of the connecting circuit are adequate to offset the voltage drop in the circuit. •E FEPP and EFEP1, 2 and 3 fixtures include elbows swivels, a conduit extension pipe (6” increments), and a combination explosion-proof junction box/mounting plate (4” box, 6 1/4” mounting center). •C omplies with NEC, OSHA and NEMA specifications for the following Classes and Groups: Class I, Division 1 & 2, Groups C & D (300W PS-25 max) Class II, Division 1 & 2, Groups E, F & G (60W max) Class III, Division 1 & 2 (150 watt max) UL Listed for use in Paint Spray Areas (75W max) Suitable for Wet Locations EFEPW= Wall bracket mount 14 lbs. EFEP1= Single 12 lbs. EFEP2= Double 21 lbs. EFEP3= Triple 30 lbs. Dimensions Dimensions are approximate and subject to change. Double Pendant Mount Pyrex® is a registered trademark of Corning Glass. Pendant Mount 25-1/2” 6” Standard Configurations for EXC Series UNIT DESCRIPTION SUFFIX Guard 22-1/8” GXP One-piece aluminum casting construction, attaches to globe holder ring with four screws. 30-7/8” 6” 13-5/8” 13-3/4” 7-1/2” Dome Reflector RD Ceiling Mount Wall Mount Highly reflective white finish inside and out, attaches to globe holder ring with four screws. Angle Reflector 7-1/2” 14-1/2” RA Highly reflective white finish inside and out, attaches to globe holder ring with four screws. 14-1/2” 13-5/8” 7-1/2” How to Order SERIES EFEP= Remote series MOUNTING LAMPS C= Ceiling mount P= Pendant W= Wall 2= Double pendant mount (HB)= 6V-8W bi-pin halogen (HD)= 6V-12W bi-pin halogen (XX6)= 6V-15W bi-pin halogen (HF)= 12V-8W bi-pin halogen (HG)= 12V-12W bi-pin halogen (AC)= 120v-25W A19 Example: EFEPC(HB)-GXP 72 OPTIONS Blank= No options -GXP= Aluminum guard -RD= Dome reflector -RA= Angle reflector EFXPW= Wall Bracket Mount TYPE: CATALOG #: SPEC GRADE NOTES: EFXP Series Explosion-Proof Remote Exit Signs Standard Features EFXPP= Adjustable Pendant Mount Dimensions are approximate and subject to change. AC-Only and AC/DC Exit Signs 6” 6”cm] [15.24 9-1/8” 9-1/8” 23.17 cm] DC Output TS Transfer Panel 6” 6”cm] [15.24 34-1/8” 34-1/8” [86.67 cm] 16-7/8” 16-7/8” [42.86 cm] 12-3/8” 12-3/8” [31.43 cm] 12-3/8” 12-3/8” [31.43 cm] 17” 17” [43.18 cm] Self-Powered Exit Sign Combination Units Output Voltage: Must be identical to DC Input Voltage Wattage: Panel oversized 10-20% greater than total connected load. 23-3/8” To Lighting Loads AC - Normal Operation DC - Emergency Operation 20-1/8” Output Input Voltage: From AC - 120 Volt, 60Hz, 1 phase (other voltages available). From DC - 6, 12, 24 or 120 Volt (select). 23-3/4” Electrical Specifications for Transfer Panel 16-7/8” 16-7/8” [42.86 cm] 17-3/4” 17-3/4” [45.08 cm] Emergency Lighting Unit AC Input assigned to same breaker and/or phase Pendant Mount Wall Mount Ceiling Mount 5-3/4” 5-3/4” [14.6 cm] 23-3/4” [60.4 cm] The transfer circuit is not designed for use in hazardous or explosive areas. The transfer circuit is to be mounted remotely from hazardous areas. EFXPC= Ceiling Mount Dimensions Pyrex® is a registered trademark of Corning Glass. Mounting INDUSTRIAL •A vailable with 6, 12 and 24 volt lamps for DC operation or 120 volt AC fixtures •E xits shown are explosion-proof fixtures of heavy cast aluminum construction with Pyrex® lenses. Exit housing is an 18 gauge fabricated steel box with a baked enamel finish. Stenciled exit lettering is available on one or two faces. All EFXP Series have extra large downlight openings •E FXP units are designed for mounting in locations that are remote from the power source. If the power source is installed outside hazardous areas, the length of the connection wires should be carefully considered to ensure that the voltage of the emergency power unit and the wire size of the connecting circuit are adequate to offset the voltage drop in the circuit •C omplies with NEC, OSHA and NEMA specifications for the following Classes and Groups: Class I, Division 1 & 2, Groups C & D (300W PS-25 max) Class II, Division 1 & 2, Groups E, F & G (60W max) Class III, Division 1 & 2 (150W max) U.L. listed for use in Paint Spray Areas (75W max) Suitable for Wet Locations 20-1/8” [51.0 cm] 23-3/8” [59.2 cm] 30-5/8” [77.8 cm] 30-5/8” 23-3/4” 23-3/4” [60.4 cm] Lamp Selection Power Consumption Chart Lamp Type 120/277VAC, 60Hz maximum 0.3/0.15A Quartz Bi-Pin Medium Base LED Lamp, Red How to Order SERIES EFXP= Exit series MOUTING C= Ceiling mount P= Pendant W= Wall Voltage Average Life (hours) Lamp Type 6V 15W JC-6V15W 2,000 XX6 25W 25A-12 1,000 XX12 24V 25W 143A 1,000 XX24 120V 25W A19 2,500 AC/20 120V 5W – 100,000 XX120 # OF FACES AC120= 120V-25W (AC only) XX120= 120V-5W LED 1= Single face 2= Double face 3= Triple face LETTERS -R= Red -G= Green Example: EFXPC(XX6)-2R AC VOLTAGE 120= 120VAC 277= 277VAC DC VOLTAGE -6= 6VDC -12= 12VDC -24= 24VDC SERIES -TS= Transfer circuit Example: 120-6-TS-25 73 Suffix 12V LAMP TYPE XX6= 6V-15W (DC only) XX12= 12V-25W (DC only) XX24= 24V-25W (DC only) Power LOAD WATTAGE -25= 25W -50= 50W -75= 75W -100= 100W TYPE: CATALOG #: SPEC GRADE NOTES: EverLite™ Series Self Luminous Exit INDUSTRIAL Features Dimensions Dimensions are approximate and subject to change. •L egend is constructed of non-glare polycarbonate, with 0.015 thick, open letters, field programmable arrows, and white letters with background colors of red or green. Contrast ratio for both conditions exceeds .5, and meets requirements of UL 924 and NFPA 101 •C onstructed of rugged thermoplastic, the EverLite™ Series offers contemporary slim line design with smooth rounded corners, and a vibrant faceplate color. Frame finishes include off-white, black or gray. The entire unit is tamperproof and completely self-contained •T ritium gas energizes the phosphor-coated borosilicate tubes in the EverLite™ sign. The low energy beta emission of tritium striking the phosphor coating inside the Pyrex® glass tubes causes illumination to be generated •S igns mount flush to wall or ceiling surfaces, a canopy is not required. •U L Listed. Complies with NFPA, Life Safety Code and OSHA •E verLite™ signs are spark free and suitable for use in hazardous, explosive, corrosive, humid or any other harsh environment. Emergi-Lite® will replace free of charge any product in which the luminosity is found to be defective during its specified luminous life, or which falls below specified luminous life 1” 8-1/4” 14” Mounting Pyrex® is a registered trademark of Corning Glass. Single Face Signs Accessories (order as a separate item) SUFFIX DESCRIPTION White Pendant P*-WT Black Pendant P*-BK Gray Pendant P*-GY Wire Guard-Wall Mount WG13-E Wire Guard-Ceiling Mount WG5-E Wire Guard-End Mount WG15-E Wall Mount (flush wall or end) Ceiling Mount (flush ceiling) Pendant Mount Double Face Signs * Specify length in inches (12, 24, 36, etc) Applications (For use in harsh or dangerous environments) Wall Mount (flush end) • Meets full test specifications of ANSI (American National Standards Institute) • Meets requirements of National Electrical Codes, Class I and II conditions • Licensed for distribution by U.S. Nuclear Regulatory Commission Pendant Mount Harsh Licenses and Codes • NFPA Life Safety Code 101 • UL 924 • City of Los Angeles • State of California • Council of American Building Ceiling Mount (flush ceiling) • Officials (ICBO, SBCCI) • OSHA • USNRC • ISO 9001 Mines Spray Booth Areas Refineries Off Shore Rigs Paper Mills Chemical Plants Food Processing Plants Grain Elevators How to Order FRAME COLOR W= Off white B= Black G= Gray SERIES SLX= Series SIGN LIFE -10= 10 years -20= 20 years # OF FACES 61= Single face 62= Double face Example: WSLX-1061R-AF-N 74 LEGEND R= Red G= Green OPTIONS -AF= Aluminum frame -AFPC= Aluminum frame and Polycarbonate shield NEW -N= NEW Table of Contents Luxray™ LED Series 78 EF24 Series 89 Lite-Ray™ Series 79 EF28 Series 90 Revelation™ Series 80 EF32 Series 91 Mini-Revelation™ Series 81 EF13 & EF17 Series 92 Distinction™ EF150 Series 82 EF15 Series 93 Distinction™ Recessed Designer Series 83 EF21R Series 94 EF9 Series 84 EF35 Series 95 EF10 Series 85 EF11 Series 96 EF14 Series 86 EF11X Series 97 EF18 Series 87 EF39, EF39P, EF40 & EF40P Series 98 EF23 Series 88 EF41 Series 99 77 REMOTE FIXTURES REMOTE FIXTURES TYPE: REMOTE FIXTURES NEMA-3R CATALOG #: Patent-Pending NOTES: Luxray™ LED Series Low-Profile, Slim Look Light Fixture Features Dimensions Dimensions are approximate and subject to change. •D ie-Cast aluminum housing, available in four finishes: dark bronze, off-white, black, and platinum gray •N ema-3R rated for indoor / outdoors wet and Damp Locations: 0-40°C (32-104°F) •W all-mount installation on various junction boxes or via rigid conduit •P atent-pending design for easy installation: wall-mount back-plate includes electrical wire box with snap-on connector •P atent pending light engine: four power LEDs with redundant connections and very wide beam •C lear polycarbonate lens of reduced size (3” X 1.5”), shockabsorbent and UV-resistant •P ower consumption in stand-by: less than 5W •5 -year limited warranty TABLE B: SPACING FOR MINIMUM ILLUMINATION = 1FC Width X Length (ft) Single Unit Window for photo-switch (optional) Minimum of 1 foot-candle TABLE A: SPACING FOR NFPA101 (AVERAGE = 1FC, SEE NOTE) Mouting Height 3” 9-1/2” Average of 1 foot-candle Model Type 6-5/8” 3” Model Type Center-To-Center Mouting Height Width X Length (ft) Single Unit Center-to-Center Standard 9’ 6’ X 50’ 6’ X 50’ With option -H 11’ 6’ X 60’ 6’ X 60’ Standard 9’ 4’ x 28’ 4’ x 32’ 3’ X 70’ With option -H 11’ 4’ x 32’ 4’ x 40’ With option -FT 12’ 6’ X 40’ – With option -FT 12’ 4’ x 22’ – With option -FTH 15’ 6’ X 50’ – With option -FTH 15’ 4’ x 27’ – 10’ 1fc m inim 1fc average 50’ um inim 1fc m 20’ um 28’ age 9’ ver 1fc a 40’ 6’ 6’ Power Consumption Chart Model Type Normal Lighting (120/277VAC) Current (max) Emergency Lighting (120/277VAC) Power (max) Current (max) 6-12VDC Remote Power (max) Power (max) AC, 2AC, ACDC, DC 0.12/0.08A 12W 0.12/0.08A 12W 8W AC, 2AC, ACDC, DC, -H 0.18/0.11A 18W 0.18/0.11A 18W 14W * Note: Only unswitched AC input; normal lighting with photo-switch or remote control How to Order COLOR B= Black BZ= Dark bronze OW= Off-white PG= Platinum gray SERIES LUX= Lux-Ray LED MODEL [ -40°F ... +122°F (-40°C ... +50°C)] AC= AC-only ACDC= AC/6-12VDC remote DC= 6-12VDC remote fixture 2AC= AC-only two circuits: 120/120 or 277/277V OPTIONS -FT= Forward throw lighting -H= High lumen output (-40... 86°F/-40…30°C) -P= Photocell Test Switch (AC, ACDC only) -RC= Remote control - infrared* (AC, ACDC only) * Remote control keypad (TB-RC1-E) ordered separately Example: BZLUXDC-FTH 78 TYPE: CATALOG #: REMOTE FIXTURES NEMA-3R NOTES: Literay™ Series Wall Mount Remote Head for Damp and Wet Locations Features Dimensions Dimensions are approximate and subject to change. • Indoor or Outdoor use •D ie-Cast aluminum construction •F ully gasketed cover available with (optional) Tamper Proof Screws •A djustable tool-less aiming swivel head rotates side to side and tilts in and out •S urface Wall Mount •U niversal knock-outs for mounting to a standard 4” octagonal electrical box •P recise beam control is provided with two fully adjustable MR16 halogen or LED lamps secured in an attractive molded swivel assembly for maximum light output •P rovides an average of one-foot candle along the path of egress •S pecially manufactured polycarbonate diffuser maximizes light output, and completes the wall sconce’s decorative lines •A vailable in four textured powder coat paint finishes: white, black, dark bronze and dark gray 5” 8” 7” How to Order SERIES LITE= Exterior remote # OF LAMPS -2= 2 lamps (standard) -1= 1 lamp (AC only) LAMP TYPE/WATTAGE (LA)= 6V-4W, MR16 LED (LG)= 2V-4W, MR16 LED (LL)= 24V-4W, MR16 LED (LV)= 120V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LJ)= 12V-6W, MR16 LED (MI)= 6V-6W, MR16 (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MD)= 24V-20W, MR16 (MS)= 24V-12W, MR16 (MA)= 12V-20W, MR16 (AC)= 1 med. base socket only (max. 60W), no lamp included, for non-emergency Example: LITE-2(MI)-WT-VR 79 COLOR -WT= White -BK= Black -DG= Dark gray -BZ= Dark bronze OPTIONS Blank= No options -VR= Vandal-resistant screws -N= Clear lens TYPE: REMOTE FIXTURES CATALOG #: NOTES: US Revelation™ DC-Remote Series Virtually Invisible, Architecturally Pleasing Features Dimensions Dimensions are approximate and subject to change. • Indoor use • Two lamp MR16 remote fixture with a choice of halogen or LED lamps •O ne-piece all-metal module design (does not require large galvanized steel back box as does the battery back-up unit) • Complete 360° door rotation, 180° to open, 180° to close •S lip gear mechanism protects the unit from objects that would cause the door rotation to be forcibly stopped. •F lat door and frame are covered with a high-quality, powder coated textured off-white finish •S urface finish can be customized on site with paint, wallpaper or other coverings. •R ecessed ceiling or wall mount with cavity space; special bar hangers for installation in sheet rock or T-bar ceilings are included. •T he module includes the electrical junction box and is installed on the wall stud or ceiling beam with the help of a simple, U-shape bracket. • Key-hole slot for ease of installation 7-1/4” 9-1/8” 3-3/4” 7-1/4” DC voltage junction box How to Order INPUT VOLTAGE 12= 12VDC 24= 24VDC SERIES RTR= Revelation remote # OF LAMPS 2= Two lamps standard Example: 12RTL2-12-DL 80 LAMP TYPE/WATTAGE -12= 12W MR16 -20= 20W MR16 -35= 35W MR16 -50= 50W MR16 -LG= 12V-4W, MR16 LED -LL= 24V-4W, MR16 LED -LI= 12V-5W, MR16 LED -LJ= 12V-6W, MR16 LED OPTIONS Blank= No options -DL= Damp Location TYPE: REMOTE FIXTURES CATALOG #: NOTES: US Mini-Revelation™ AC Generator Remote Series THE UNSEEN SOLUTION Virtually Invisible Emergency Lighting Features Dimensions Dimensions are approximate and subject to change. •2 0 gauge galvanized steel back-box •H ead assembly designed for easy access to internal components •H ead assembly door and trim plate powder coated in a white finish •F inish can be customized on site with paint or wallpaper •P rovision for 2 lighting heads •C hoice of MR16 Halogen or MR16 LED lamp types and wattages •C omplete 360° head assembly door rotation: 180° to open, 180° to close •R ecessed mount into ceiling or wall with cavities •S pecial bar hangers included for installation in dry wall or T-bar ceilings • Includes the electrical junction box • Installed on the wall stud or ceiling beam with simple, U-shape bracket •H ead assembly includes keyhole slot and quick-connect plugs for easy installation 5-1/4” 7” 9-1/8” 7-3/4” Complete unit 17-5/8” Mounting Bracket Installed unit How to Order SERIES MRT AC INPUT G= Remote AC generator 1= 120 VAC 2= 277 VAC LAMP TYPE/WATTAGE -2(12)= 12W each head -2(20)= 20W each head -2(35)= 35W each head -2(50)= 50W each head -2(20H)= 20W, high lumen output -2(35H)= 35W, high lumen output -2(50H)= 50W, high lumen output -2(-LG)= 12V-4W, MR16 LED -2(-LI)= 12V-5W, MR16 LED -2(-LJ)= 12V-6W, MR16 LED Example: MRTG1-2(20)DL 81 OPTIONS Blank= No options DL= Damp Location TYPE: REMOTE FIXTURES CATALOG #: NOTES: Distinction™ EF150, EF150D & EF150T Series Surface Mounted Designer Light Fixtures Features Dimensions Dimensions are approximate and subject to change. •W hite or black finish available. •E F150: Single compact adjustable decorative lighting head. Dimensions: 4.48” diameter base, 5.2” height •E F150D: Double compact adjustable decorative lighting heads. Dimensions: 4.48” diameter base, 4.0” height EF150 • EF150T: T riple compact adjustable decorative lighting heads. Dimensions: 11.0” diameter base, 5.2” height • Indoor use •D ie-Cast aluminum •F ully tool-less adjustable aiming swivel head •C lear glass lense •S urface mount • Includes canopy plate for mounting to a standard 4” octogonal electrical box 4-5/8” 5” 80° 320° Accessories (order as a separate item) PART NUMBER DESCRIPTION Wire Guard for EF150, EF150D WG8-E Wire Guard for EF150T WG2-E EF150T EF150D 9-5/8” 4” 5” How to Order SERIES EF150= Decorative MR16 remote head # OF HEADS Blank= Single head D= Double head T= Triple head COLOR Blank= White -B= Black LAMP TYPE/WATTAGE (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LL)= 24V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LJ)= 12V-6W, MR16 LED (LV)= 120V-4W, MR16 LED (M_)= Halogen MR16 50W max* * See lamp chart for lamp code 50W use heat shield Example: EF150D-B(MK) 82 TYPE: REMOTE FIXTURES CATALOG #: NOTES: Distinction™ Series Remote Recessed Designer Light Fixtures Features Dimensions Dimensions are approximate and subject to change. • Indoor Use • Powder-coated Die-Cast aluminum construction • Tool-less lamp head adjust ability • Glass MR16 lamp lens • Choice of MR16 Halogen or LED lamp • Choice of White, Black, Chrome, Brushed Nickel or Polished Brass • Recessed ceiling mount •M ust order appropriate housing with decorative head selection for installation into new construction ceiling (EL-GRHR03) or insulated ceiling (EL-GRHR06) New construction housing. Total height: 5.6”. 5-3/5” 4” 7-4/5” 14-1/4” EL-GRHR03 Insulated ceilings housing Total height: 7.25” 7-1/4” 4” 11-1/4” 14-1/4” EL-GRHR06 SERIES LED LAMP SUFFIX EFR2 Description: Decorative pop-up adjustable lighting head Dimensions: 4.0” diameter base Color Suffix: -WH= White, -BK= Black, -CH= Chrome, -PB= Polished brass, -BN= Brushed Nickel Required recessed housing N/A EFR8NB Description: Decorative adjustable lighting head Dimensions: 4.0” diameter base Color Suffix: -WH= White or -BN= Brushed nickel Requires recessed housing LA= 6V-4W, MR16 LED LG= 12V-4W, MR16 LED LL= 24V-4W, MR16 LED EFR8R Description: Decorative adjustable lighting head Dimensions: 4.0” diameter base Color Suffix: -WH = White or -BN = Brushed nickel Requires recessed housing LA= 6V-4W, MR16 LED LG= 12V-4W, MR16 LED LL= 24V-4W, MR16 LED LI= 12V-5W, MR16 LED LJ= 12V-6W, MR16 LED LV= 120V-4W, MR16 LED EFR9WH Description: Decorative adjustable lighting head Dimensions: 4.0” diameter base Color Suffix: -WH = White Requires recessed housing LA= 6V-4W, MR16 LED LG= 12V-4W, MR16 LED LL= 24V-4W, MR16 LED LI= 12V-5W, MR16 LED LJ= 12V-6W, MR16 LED LV= 120V-4W, MR16 LED EL-GRHR03 Housing Enclosure Description: New construction housing Dimensions: 5.6” x 14.24” New construction housing – EL-GRHR06 Housing Enclosure Description: Insulated ceilings housing Dimensions: 7.25” x 14.24” Insulated ceilings housing – How to Order SERIES EFR2 EFR8NB COLOR* EFR8R EFR9WH LAMP TYPE/WATTAGE -(L_)= LED MR16 (see table above)* -(M_)= Halogen MR16* * Choose color from the above table * For a complete list of available lamp types, please refer to the lamp data on pages 144-145 Example: EFR8R-BK-(MA) HOUSING EL-GRHR03= New Construction EL-GRHR06= Insulated Ceilings 83 TYPE: REMOTE FIXTURES CATALOG #: NOTES: Surface Mounted EF9, EF9D & EF9T Series Thermoplastic PAR 18 Size Lamp Head Features Dimensions Dimensions are approximate and subject to change. •O ff-white finish; black (BK) optional •S urface (wall or ceiling) mounting direct to 4” octagonal or single-gang box •L amps (for alternate lamp selection, see lamp data sheet): lamp type H: BI-PIN halogen or lamp type Z: High intensity incandescent wedge base •T hermoplastic construction • Indoor use •F ully adjustable tool-less aiming swivel head •S pecular parabolic reflector and prismatic lens for wide-beam, even light distribution •S nap-out lens for easy lamp replacement •S urface mount • Includes a 5” round universal canopy plate with 3 knock-outs (supplied with 2 plugs) for use with single, double or triple head mounting EF9 2-15/16” 3-3/16 5-9/16” 5” EF9D 8-5/16” 3-3/16” 4-13/16” 5” EF9T 3-3/16” 8-1/2” 5-5/8” 5” How to Order SERIES EF9= PAR 18 remote head # OF HEADS Blank= Single head D= Double head T= Triple head LAMPT TYPE/WATTAGE (H_)= Halogen bi-pin 12W max* (Z_)= Tungsten wedge 18W max* * For a complete list of available lamp types, please refer to the lamp data on pages 144-145 Example: EF9D(HB)BK 84 COLOR Blank= Off white BK= Black TYPE: REMOTE FIXTURES CATALOG #: NOTES: Surface Mounted EF10, EF10D & EF10T Series Thermoplastic MR16 Lamp Head Features Dimensions Dimensions are approximate and subject to change. •T hermoplastic construction with off-white finish; black (BK) •D irect mounting to 4” octagonal electrical box •S eries M Lamps: MR16 • Indoor use •A vailable as a single, double or triple PAR 18 size MR16 lighting head • Fully adjustable tool less aiming swivel head •S pecular parabolic reflector and prismatic lens for wide-beam, even light distribution •S nap-out lens for easy lamp replacement. • Surface Mount • Includes a 5” round universal canopy plate with 3 knock-outs (supplied with 2 plugs) for use with single, double or triple head mounting 2-7/8” 8-1/4” 5” 5” 3-1/4” 5-5/8” 3-1/4” 4-7/8” How to Order SERIES EF10= MR16 PAR18 remote head # OF HEADS LAMP TYPE/WATTAGE Blank= Single head D= Double head T= Triple head (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LL)= 24V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LJ)= 12V-6W, MR16 LED (M_)= Halogen MR16 20W max* * 20W Halogen is only available in 12V (MA) Example: EF10D(LA)BK 85 COLOR Blank= Off-white BK= Black TYPE: REMOTE FIXTURES CATALOG #: NOTES: Surface Mounted EF14 Series Remote Fixture Features Dimensions Dimensions are approximate and subject to change. • Rectangular fixture with diffused polycarbonate lens • White baked enamel finish (specify other) • Surface wall or ceiling mounting •L amps (for alternate lamp selection, see lamp data sheet page 146-147): Series I - High intensity tungsten (HIT) double contact bayonet base 8-1/4” 4-1/4” Lamp type(s), voltage and maximum wattage available for fixture are shown under lamp description. Determine lamp type, voltage and wattage required for your application, then select lamp from Lamp Chart in the Charts & Diagrams in the Accessories & General Information Section on page 146-147 section. Do not exceed fixture wattage rating. Include lamp suffix and voltage as suffix to model number. Voltage must be stated. Steel Housing 3-1/4” 3” Knock-outs 4” Cover Diffusion Lens 4-1/2” How to Order SERIES EF14= Remote fixture LAMP TYPE/WATTAGE (I_)= Tungsten double contact bayonet base 25W max, (6, 12, 24 Volts)* (I_)= Tungsten double contact bayonet base 15W max, (120 VAC)* * For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: EF14(IA)BK 86 COLOR Blank= Off white BK= Black TYPE: REMOTE FIXTURES CATALOG #: NOTES: Surface Mounted EF18, EF18D & EF18T Series Thermoplastic PAR 36 Lamp Head Features Dimensions Dimensions are approximate and subject to change. •T hermoplastic construction with off-white finish; black (BK) optional •L amps (for alternate lamp selection, see lamp data sheet): Type H: BI-PIN halogen. Type I: High intensity tungsten (HIT) double contact bayonet base. Type U: Sealed beam tungsten. Type X: Sealed beam halogen or Type Z: High intensity incandescent wedge base • Indoor use •A vailable as a single, double or triple PAR 36 size lighting head •F ully adjustable tool less aiming swivel head •S pecular parabolic reflector and prismatic lens for wide-beam, even light distribution •S nap-out lens for easy lamp replacement. •S urface Mount • Includes a 5” round universal canopy plate with 3 knock-outs (supplied with 2 plugs) for use with single, double or triple head mounting •M ounts to either a standard 4” octagonal or a single gang electrical box (4-gang plate for EF18T optional) EF18 7-1/4” 5” EF18D 10-7/8” 3-1/2” 6-3/8” 5” Accessories (order as a separate item) PART NUMBER DESCRIPTION EF18T WG9-E 13-3/8” 6-3/8” Wire Guard 3-5/8” 4-3/4” 9-1/2” How to Order SERIES EF18= PAR 36 remote head # OF HEADS LAMP TYPE/WATTAGE Blank= Single head D= Double head T= Triple head (H_)= Halogen bi-pin 20W max* (I_)= Tungsten wedge 25W max* (Z_)= Tungsten wedge 18W max* (U_)= Tungsten sealed beam 30W max* (X_)= Halogen sealed beam* 50W max** * For a complete list of available lamp types, please refer to the lamp data on pages 146-147 ** Use high temp enclosure Example: EF18D(ZD)BK 87 COLOR Blank= Off white BK= Black TYPE: REMOTE FIXTURES CATALOG #: NOTES: Surface Mounted EF23 & EF23D Series Thermoplastic square Lamp Head Features Dimensions Dimensions are approximate and subject to change. •T hermoplastic construction with off-white or black (BK) finish. •A vailable as a single, or double square lighting head •F ully adjustable tool less aiming swivel •S pecular parabolic reflector and prismatic lens for wide-beam, even light distribution •S nap-out lens for easy lamp replacement •S urface Mount •M ounts to either a standard 4” octagonal or a single gang electrical box. (4gang plate for EF23D optional) •R ound mounting canopy standard. •L amps (for alternate lamp selection, see lamp data sheet): Series H: BI-PIN halogen 6, 8 and 12 watt lamps only. or Series Z: High intensity incandescent wedge base 5.4, 9 and 12 watt lamps only. EF23 4-3/8” 5-5/8” 5” Accessories (order as a separate item) EF23D Wire Guard 8-1/8” [20.63cm] 8-1/8” PART NUMBER DESCRIPTION WG8-E 5-1/2” 5-1/2” [13.97cm] 5” [12.7cm] 5” How to Order SERIES EF23= Remote SQ Fixture # OF HEADS Blank= Single head D= Double head LAMP TYPE/WATTAGE (Z_)= Wedge base, 12W Max, (6, 12, 24 Volts)* (H_)= Bi-pin halogen, 12W max, (6, 12 Volts)* * For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: EF23D(HB)BK 88 COLOR Blank= Off white BK= Black TYPE: REMOTE FIXTURES CATALOG #: NOTES: Surface Mounted EF24 & EF24-2 Series Surface Mount square Features Dimensions Dimensions are approximate and subject to change. •D ecorative square thermoplastic light with prismatic diffusing lens and metal reflector •O ff-white front trim; black back-box •D imensions: 9” X 9” X 4” deep •S urface (wall or ceiling) mounting •F or semi-recessed mounting, order EF24R, semi-recessed deep mounting box included (8-1/2” X 8-1/2” X 1-3/4” deep) •P lated steel reflector for wide-beam, even light distribution •S nap-out lens for easy lamp replacement •L amps (for alternate lamp selection, see lamp data sheet): Type H: BI-PIN halogen Type I: High intensity tungsten (HIT) double contact bayonet base or Type Z: High intensity incandescent wedge base Side 4” 7-7/8” 9” 2-1/4” Accessories (order as a separate item) Front PART NUMBER DESCRIPTION Wire Guard Rear WG1-E 8-1/4” 9” 9” 8-1/4” 9” 9” How to Order SERIES LAMP TYPE/WATTAGE EF24= Remote fixture EF24-2= Remote fixture lamp double* (Z_)= Wedge base, 20W max, (6, 12, 24 Volts)* (H_)= Bi-Pin halogen, 20W max, (6, 12 Volts)* (I_)= Double contact bayonet, 20W max, (6, 12, 24 Volts)* *Only available with Bi-pin halogen lamps * For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: EF24-2(HA) 89 TYPE: REMOTE FIXTURES CATALOG #: NOTES: Surface Mounted EF28, EF28D, EF28T & EF28D Series Aluminum PAR 36 Lamp Head Features Dimensions Dimensions are approximate and subject to change. •S ingle or double metal housing head with fully adjustable swivel •S pectacular parabolic reflector and prismatic lens for wide-beam, even light distribution • Include a circular universal canopy plate for mounts a standard 4” octogonal or a single gang electrical box (4-gang plate for EF28T optional. See page 146-147 for detail) •C hrome finish head (off-white optional) •E F28: surface mounting; 1 MPC - 1 plate supplied •E F28D: surface mounting; 3 MPC - 2 plate supplied •E F28: mounting plate dimensions: 2-1/2” X 4-1/4” •E F28D: mounting plate dimensions: 6-7/16” X 4-1/2” •L amps (for alternate lamp selection, see lamp data sheet): Type H: BI-PIN halogen Type I: High intensity tungsten (HIT) double contact bayonet base Type U: Sealed beam tungsten Type X: Sealed beam halogen or Type Z: High intensity incandescent wedge base EF28 7-1/8” 5-1/8” EF28D Accessories (order as a separate item) Wire Guard 6-5/8” PART NUMBER DESCRIPTION WG9-E 10-1/4” 5-1/8” EF28T 7-1/4” 11-7/8” 5-1/8” How to Order SERIES EF28= Aluminum Remote Fixture # OF HEADS Blank= Single head D= Double head T= Triple head LAMP TYPE/WATTAGE (Z_)= Wedge base, 18W max, (6, 12, 24 Volts)* (H_)= Bi-pin halogen, 20W max, (6, 12 Volts)* (I_)= Double contact bayonet, 25W max, (6, 12, 24 Volts)* (U_)= Sealed beam incandescent, 30W max, (6, 12 Volts)* (X_)= Sealed beam halogen, 50W max, (6, 12 Volts)* * For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: EF28D(ZD)WT 90 COLOR Blank= Chrome WT= Off-white TYPE: REMOTE FIXTURES CATALOG #: NOTES: Surface Mounted EF32 & EF32D Series Aluminum Cylinder Lamp Head Features Dimensions Dimensions are approximate and subject to change. •S ingle miniature fully adjustable aluminum cylinder complete with matching round mounting plate •O ff-white baked enamel finish standard, black (BK) optional. •C ylinder dimensions: 3” diameter x 4-1/4” •L amps (for alternate lamp selection, see lamp data sheet refer to page 146-147 ): Series H: BI-PIN halogen 6 or 12 VDC only • Indoor use •F ully adjustable aiming swivel head •M irror finished reflector and prismatic lens for wide-beam, even light distribution • Surface mount • Includes a round universal canopy plate • Mounts to a standard 4” octogonal electrical box EF32 6-1/4” 5-1/2” 5-1/8” EF32D Accessories (order as a separate item) 8-1/2” Wire Guard 6-1/4” PART NUMBER DESCRIPTION WG8-E 5-1/8” 5-1/8” How to Order SERIES EF32= Remote Fixture # OF HEADS LAMP TYPE/WATTAGE Blank= Single head D= Double head (H_)= Bi-pin halogen, 20W max, (6, 12 Volts)* * For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: EF32D(HB)BK 91 COLOR Blank= Off-white BK= Black TYPE: REMOTE FIXTURES CATALOG #: NOTES: Recessed Mounted EF13 Series Remote Fixture Features Dimensions Dimensions are approximate and subject to change. •R ectangular fixture with diffused polycarbonate lens •W hite baked enamel finish; black also available •R ecessed wall or ceiling mounting •T rim plate dimensions: 8-1/4” X 4-1/2” •B ack box dimensions: 6-3/8” X 3” X 2-5/8” deep •L amps (for alternate lamp selection, see lamp data sheet on page 144): Series I - High intensity tungsten (HIT) double contact bayonet base 8-1/4” 4-1/4” 2” Steel Housing 3-1/4” Knock-outs 4” How to Order SERIES LAMP TYPE/WATTAGE EF13= Remote fixture 3” (I_)= tungsten double contact bayonet base 25W max, (6, 12, 24 Volts )* (I_)= tungsten double contact bayonet base 15W max, (120 VAC)* COLOR Cover Blank= Off-white BK= Black Diffusion Lens 4-1/2” * For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: EF13(IC)BK Recessed Mounted EF17 Series Remote Fixture Features Dimensions Dimensions are approximate and subject to change. •R ecessed adjustable eyeball PAR 36. •B rushed aluminum finish (specify others). •R ecessed wall or ceiling mounting. •T rim ring dimensions: 8-3/4” diameter. •B ack dimensions: 6-3/4” X 3-1/2” deep. 6-1/2” 3-1/2” How to Order SERIES LAMP TYPE/WATTAGE EF17= Recessed adjustable eyeball (Z_)= Wedge base, 18W max, (6, 12, 24V)* (H_)= Bi-pin halogen, 20W max, (6, 12V)* (I_)= Double contact bayonet, 25W max, (6, 12, 24V)* (U_)= Sealed beam inc, 30W max, (6, 12V)* (X_)= Sealed beam halogen, 50W max, (6, 12V)* COLOR Blank= Aluminum WT= Off- white 8-1/2” NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: EF17(ZL)WT 92 TYPE: REMOTE FIXTURES CATALOG #: NOTES: Recessed Mounted EF15 Series Remote Gimbal Fixture Features Dimensions Dimensions are approximate and subject to change. • Indoor use •A single lamp recessed round Gimbal PAR 36 lighting head •L amp has horizontal rotation of 358° and vertical angle adjustable to 42° •S napout lens for easy lamp replacement •R ecessed gimbal ring fixture PAR 36 - adjustable in two planes to 45° •O ff-white thermoplastic housing •R ecessed wall or ceiling mounting •C omplete unit, no additional housing needed 9” Accessories (order as a separate item) PART NUMBER DESCRIPTION Wire Guard PLASTER FRAME WG11-E TRIM 9” GIMBAL RING 6-1/4” Min. Ceiling Opening 5-1/2” WIRE BOX 4-1/2” BACK BOX 5-1/4” 5-1/2” How to Order SERIES EF15= Remote Gimbal Fixture LAMP TYPE/WATTAGE (Z_)= Wedge base, 18W Max, (6, 12, 24V)* (H_)= Bi-pin halogen, 20W Max, (6, 12V)* (I_)= Double contact bayonet, 25W Max, (6, 12, 24V)* (U_)= Sealed beam incandescent 30W Max, (6, 12V)* (X_)= Sealed beam halogen, 20W Max, (6, 12V)* * See lamp chart on page 146 for lamp code Example: EF15(ZD)BK 93 COLOR Blank= Off-white BK= Black TYPE: REMOTE FIXTURES CATALOG #: NOTES: Recessed Mounted EF21R Series Fully Recessed Metal Decorator Square Features Dimensions Dimensions are approximate and subject to change. •F ully recessed metal decorator square housing with prismatic diffusing lens and metal reflector •O ff-white baked enamel finish •R ecessed wall or ceiling mounting •F ully recessed frame, metal construction • Available as a single, or double lamp lighting head • Prismatic acrylic lens •P lated steel reflector for a wide-beam, even light, distribution •U niversal knock-outs to mount a standard 4” octagonal electrical box •S upport bars or rods supplied by others •L amps (for alternate lamp selection, see lamp data sheet on page 144): Type H: BI-PIN halogen (available at additional cost) Type I: High intensity tungsten (HIT) double contact bayonet base or Type Z: High intensity incandescent wedge base 9-7/8” 9-7/8” Accessories (order as a separate item) PART NUMBER DESCRIPTION Wire Guard WG11-E 8-11/16” 3-1/16” How to Order SERIES LAMP TYPE/WATTAGE EF21R= Remote recessed metal square decorator fixture (Z_)= Wedge base, 20W max, (6, 12, 24 Volts)* (H_)= Bi-pin halogen, 20W max, (6, 12 Volts)* (I_)= Double contact bayonet, 20W max, (6, 12, 24 Volts)* * For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: EF21R(ZD) 94 TYPE: REMOTE FIXTURES CATALOG #: NOTES: Recessed Mounted EF35 Series Remote Fixture Features Dimensions Dimensions are approximate and subject to change. •G asketed, fully recessed, with fresnel lens; suitable for Damp locations •O ff-white finish •F ully recessed ceiling mounting •T rim: plastic, off-white •R ecessed (wall or ceiling). Plaster frame and standard 4” wire box provided •T rim ring: 8-1/2” diameter • EF35 Series: W edge base incandescent 18W MAX Double contact Bayonet base 25W MAX Bi-pin halogen 20W MAX •6 , 12, 24VDC •M aximum power: 25W low voltage 14” to 24” 7” 10-1/4” 8-1/2” 7-3/4” 6-1/2” How to Order SERIES LAMP TYPE/WATTAGE EF35= Remote Metal Fixture (Z_)= Wedge base, 20W max, (6, 12, 24V)* (H_)= Bi-pin halogen, 20W max, (6, 12V)* (I_)= Double contact bayonet, 20W max, (6, 12, 24V)* Only available with Bi-pin halogen lamps * For a complete list of available lamp types, please refer to the lamp data on pages 146-147 Example: EF35(IA) 95 TYPE: REMOTE FIXTURES CATALOG #: NOTES: Weatherproof EF11, EF11D & EF11T Series Thermoplastic Weather-Resistant PAR 36 Lamp Head Features Dimensions Dimensions are approximate and subject to change. •O utdoor use •A vailable as a single, double or triple PAR 36 size lighting head •T hermoplastic construction with aluminum canopy plate •F ully adjustable aiming swivel head •S pecular parabolic reflector and prismatic lens for a wide-beam, even light distribution •S ealed for rain; dust-tight; corrosion resistant • Off-white, black or gray •S urface mount •M ounts to a standard 4” octagonal electrical box 4-3/4” 4-1/4” Accessories (order as a separate item) 3-3/4” 12-1/2” EF11D 5-1/2” PART NUMBER DESCRIPTION Wire Guard 3-3/4” 7-1/4” EF11 WG9-E 4-1/4” EF11T 7-1/4” 12-1/2” 4-1/4” How to Order SERIES EF11= PAR 36 remote head (Weatherproof) # OF HEADS LAMP TYPE/WATTAGE Blank= Single head D= Double heads T= Triple heads (H_)= Halogen bi-pin 20W max* (I_)= Tungsten wedge 25W max* (Z_)= Tungsten wedge 18W max* (U_)= Tungsten sealed beam 30W max* (X_)= Halogen sealed beam* 50W max** * For a complete list of available lamp types, please refer to the lamp data on pages 146-147 ** Use high temp enclosure Example: EF11D(HD)WT 96 COLOR Blank= Black* WT= Off-white * XI lamps available in gray only heads TYPE: REMOTE FIXTURES CATALOG #: NOTES: Weatherproof EF11X & EF11DX Series Class I Division 2 Certified Remote Fixture Features Dimensions Dimensions are approximate and subject to change. •C lass I Division 2 - Groups A, B, C, D •S ingle lighting head with fully adjustable swivel with gray lamp heads •G asketed aluminum canopy and junction box • Indoor use •A vailable as a single or double PAR 36 size •S urface mount • Includes a universal aluminum canapy and junction box •C onduit entry 1/2” NPT •L amps: PAR 36 sealed beam (6 or 12VDC maximum 12W) EF11X 5” 4-3/4” Accessories (order as a separate item) 8-7/8” PART NUMBER DESCRIPTION Wire Guard 1-3/4” WG6-E 4-3/16” EF11DX 12” 4-3/16” How to Order EF11X SERIES SERIES EF11= Hazardous locations Class.I Div.2 Groups A, B, C and D MODEL X= Single head LAMP TYPE/WATTAGE (XD)= 6V-12W halogen sealed beam (XG)= 12V-12W halogen sealed beam Example: EF11X(XD) EF11DX SERIES SERIES EF11= Hazardous locations Class.I Div.2 Groups A, B, C and D MODEL DX= Double head Example: EF11DX(XG) 97 LAMP TYPE/WATTAGE (XD)= 6V-12W halogen sealed beam (XG)= 12V-12W halogen sealed beam TYPE: CATALOG #: REMOTE FIXTURES NEMA-4X NOTES: Survive-All™ EF39 & EF40 Series EF39 NEMA-4X & NSF Certified EF40 Vandal Resistant Features Dimensions Dimensions are approximate and subject to change. •F ully gasketed with a selection of cast aluminum or polycarbonate back plate •C lear polycarbonate UV and impact resistant lens • Choice of single or double lamp models •A vailable in 6, 12 and 24V models MR16 or LED •E asy lamp replacement •E F39 comes standard with tamper-proof screws and bit •N SF Certified for food processing plants •N EMA-4X Certified •E F39P and EF40P require mounting plate option when installed on surface mount junction box •C SA Certified to C22.2 No. 141 •S uitable for indoor/outdoor installation 7-1/8” 3-3/4” 4-5/8” Accessories (order as a separate item) SUFFIX DESCRIPTION Additional special bit for tamper-proof screws 690.0454-E How to Order EF39 Series SERIES LAMP TYPE/WATTAGE EF39P= All polycarbonate single head NEMA-4X EF39PD= All polycarbonate double head NEMA-4X (MI)= 6V-6W, MR16 (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MS)= 24V-12W, MR16 (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LL)= 24V-4W, MR16 LED (LJ)= 12V-6W, MR16 LED LAMP TYPE Blank= White -BK= Black -GY= Gray OPTION SM= Mounting plate Example: EF39P(LG)-BK SERIES LAMP TYPE/WATTAGE EF39= Die-Cast back plate single head NEMA-4X EF39D= Die-Cast back plate double head NEMA-4X (MI)= 6V-6W, MR16 (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MS)= 24V-12W , MR16 (MD)= 24V-20W, MR16 (MW)= 12V-20W, MR16-IR (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LL)= 24V-4W, MR16 LED (LJ)= 12V-6W, MR16 LED LAMP TYPE Blank= White -BK= Black -GY= Gray Example: EF39(LG)-BK How to Order EF40 Series SERIES EF40P= All polycarbonate single head for dry locations EF40PD= All polycarbonate double head for dry locations LAMP TYPE/WATTAGE (MI)= 6V-6W, MR16 (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MS)= 24V-12W, MR16 (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LL)= 24V-4W, MR16 LED (LJ)= 12V-6W, MR16 LED COLOR Blank= White -BK= Black -GY= Gray OPTIONS Blank= No options T= Tamper proof screws SM= Mounting plate Example: EF40P(MK) SERIES EF40= Die-Cast back plate single head for dry locations EF40D= Die-Cast back plate double head for dry locations LAMP TYPE/WATTAGE (MI)= 6V-6W, MR16 (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MS)= 24V-12W , MR16 (MD)= 24V-20W, MR16 (MW)= 12V-20W, MR16-IR Example: EF40D(MD) 98 (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LL)= 24V-4W, MR16 LED (LJ)= 12V-6W, MR16 LED COLOR Blank= White -BK= Black -GY= Gray OPTIONS Blank= No options T= Tamperproof screws TYPE: REMOTE FIXTURES CATALOG #: NOTES: US Survive-All™ EF41 Series Class I Division II Certified Remote Fixture Features Dimensions Dimensions are approximate and subject to change. •A vailable with single or double lamp heads with high-efficiency MR16 halogen lamps of 10W, 12W or 20W (see How to Order information) •D ie-Cast aluminum back plate with gasket. Clear polycarbonate cover, UV and impact resistant • Input voltage: 6V, 12V or 24V •E asy installation on a 4” octagonal box (included). Comes standard with tamper-proof screws and bit •E valuated to UL 844 Standard for Class I Division 2, Groups A, B, C and D Temperature Codes: T3B (10W and 12W MR16 lamps) and T2C (20W MR16 lamps). Extreme operational temperature range: -40ºF to 104ºF (-40ºC to +40ºC) • Fully adjustable tool-less aiming swivel • Indoor use • Conduit entry 1/2” NPT 7-1/8” 4-5/8” 5-7/8” remote fixture 3-3/4” junction box 2-1/8” 4” junction box How to Order SERIES EF41= Single lamp EF41D= Double lamp LAMP TYPE/WATTAGE (MJ)= 6V-10W, MR16 (MK)= 12V-12W, MR16 (MW)= 12V-20W, MR16-IR (MS)= 24V-12W, MR16 (MD)= 24V-20W, MR16 (MT)= 120VAC/VDC-20W MR16(GU10) (LA)= 6V-4W, MR16 LED (LG)= 12V-4W, MR16 LED (LI)= 12V-5W, MR16 LED (LJ)= 12V-6W, MR16 LED (LL)= 24V-4W, MR16 LED (LW)= 12V-4W, MR16 LED (C/W wires) * Wattage doubles for “D” 2-lamp version Example: EF41(MJ)-GY 99 COLOR -GY= Gray DISTRIBUTOR SELECT What are DISTRIBUTOR SELECT PRODUCTS? Distributor Select Replenishing your stock of popular emergency lighting equipment and exit signs is easy with Emergi-Lite® Distributor Select products. Our catalog numbers allow you to order each item with the exact specifications you need from the many standard options available. Large inventories of Emergi-Lite® Distributor Select products are quick to ship from multiple warehouses across the United States for next day delivery, and our picking, packing and shipping process has been streamlined to fulfill distributor orders without delay. Offer your customers a wide range of Emergi-Lite® emergency lighting equipment and exit signs, including decorative battery units, 6-24 volt units, exit signs and combo units, remote heads, environmentally-friendly LED models, and more. Table of Contents 101 Prestige™ Thin Series 102 Total™ Edge-Lit Series 103 EL-2LED Series 104 ELXN400 LED Series 105 EF43D & EF44D Series 105 DLM-2 Series 106 GS Series 107 EL-2SQ Series 108 ELX400 SQ Series 109 EL-2MRS & 12EL50-2MRS Series 110 ELX-MRS Series 111 ELX Series 112 Quick Switch Series 113 DISTRIBUTOR SELECT DISTRIBUTOR SELECT DISTRIBUTOR SELECT TYPE: CATALOG #: NOTES: Prestige™ Thin Series Die-Cast Aluminum Slim Profile Exit Sign With Long-Lasting LED Performance Standard Features Dimensions Dimensions are approximate and subject to change. •E asy to install •T wo popular finishes (see below) •S elf-Powered models with Nickel-Cadmium battery •L ow power consumption •F ield-selectable, knockouts chevrons •U niversal installation: top, end and back-mounting •U L 924 Damp Location listed •M eets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards •F ive-year full warranty 3/8” [1.0cm] • Die-Cast aluminum housing, thin profile •C lear lacquer, brushed aluminum inhibits fingerprints and other surface contaminants. Also available with white finish •U niversal directional chevron knockout are completely concealed and easily removed from face-plate •L etters are 6” high with 3/4” stroke and 100 ft viewing distance rating 5-1/8” [13.0cm] Construction 7-3/4” [19.7cm] 8-1/8” [20.6cm] 4-3/8” [11.1cm] 7/8” [2.2cm] 11-7/8” [30.2cm] 12-1/4” [31.1cm] Electrical • Dual-voltage input capability 120/277VAC •S elf-Powered models are provided with test switch, LED pilot light and rechargeable Nickel-Cadmium battery •B attery: Sealed, maintenance-free, Nickel-Cadmium battery delivers 90 minutes of emergency power on all Self-Powered models Power Consumption Chart Model Installation Universal mounting – top, back or end. Mounting knockout and hole plugs are easily removed. Die-Cast aluminum canopy is provided (white canopy with white frame and black canopy with black frame) AC Specs AC-only 120/277 VAC 60Hz SelfPowered 120/277 VAC 60Hz DC Specs Typical 1W Less than 1.5W – – Typical 1W Less than 1.5W Ni-Cd battery Min. 90 minutes Listings Accessories (order as a separate item) UL Listed. Damp Location listing 32°F to 122°F (ذC to 50°C). Meets UL 924, NFPA 101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. SUFFIX DESCRIPTION Warranty Wire Guard (wall mount) WG1-E Five-year full warranty Wire Guard (ceiling mount and end mount) WG5-E How to Order FRAME COLOR/FACE PLATE BA= Black body/brushed aluminum face WW= White/white SERIES TX= AC only TXN= Self-Powered unit (90 min.) # OF LAMPS 1= Single face 2= Double face Example: BATXN1R 102 LEGEND COLOR R= Red G= Green TYPE: DISTRIBUTOR SELECT CATALOG #: NOTES: Total Edge™ Series Single and Double Face, Surface and Recessed Mount Edge-Lit Exit Sign Standard Features Dimensions Dimensions are approximate and subject to change. • Surface, recessed* or end-mount • High performance low power consumption LEDs • Peel-off chevrons • Special wording panel not available 14-1/2” 4-3/8” Construction •B rushed aluminum housing and black plastic end-caps, with high grade acrylic panel. •C hoice of legend colors: red on mirror or green on mirror 11-1/2” Electrical 3-1/2” •D ual-voltage input capability 120/277VAC •S elf-powered models feature battery delivering more than 90 minutes capacity in emergency mode 4-3/8” 3/4” Installation 10-3/8” 4” 2-7/8” 9-1/8” Surface mount: Pivoting panel design allows for surface installation in any applications, including ceilings and walls. Semi recessed* mount: Includes back box and necessary hardware for joist or T-Bar ceilings and is vertically adjustable to install in most ceiling thickness. Mounting bars lock in place with two screws. Listings UL924 listed 3-1/2" 13" 13” Warranty 3 year full warranty, excluding lamps and fuses 1-5/8" * Not intended for closed ceilings such as sheet-rock or plaster. Power Consumption Model AC Only Red Self-Powered AC Only Green Self-Powered AC Specs 120VAC, 60Hz 277VAC, 60Hz 120VAC, 60Hz 277VAC, 60Hz 2.0-2.6W 2.6-3.1W 2.0-2.6W 2.6-3.1W Ni-Cd battery Ni-Cd battery Min. 90 Minutes Min. 90 Minutes 120VAC, 60Hz 277VAC, 60Hz 120VAC, 60Hz 277VAC, 60Hz 2.8-3.3W 3.5-4W 2.8-3.3W 3.5-4W Ni-Cd battery Ni-Cd battery Min. 90 Minutes Min. 90 Minutes 9-5/8” 9-5/8" 8-11/16" DC Specs 3-1/2" 3-1/2” 13" 1-5/8” 1-5/8" 8-3/4” 8-11/16" 3-1/2” 7-1/8” 9-5/8" How to Order SERIES PA= AC Only PN= Self-Powered PA2= AC only Dual Circuit COLOR R= Red on mirror G= Green on mirror LEGEND 6= 6” EXIT Single & Double face with universal chevrons Example: PAR6 103 DISTRIBUTOR SELECT TYPE: CATALOG #: NOTES: EL-2LED Series Low Energy, Low Maintenance Emergency Lighting for Moderate Budget Applications 9” [22.86cm] Features Dimensions Dimensions are approximate and subject to change. • Fully adjustable LED glare-free heads • 3.6V-3.6W long-life LED illumination with life expectancy of 50,000 hrs Construction • Injection-molded, UV stabilized thermoplastic • UL94, 5VA flame rated body • Snap-together design • Corrosion and scratch-resistant in mist white color 9” [22.86cm] 9” 2-3/4” [5.08cm] 4” [10.16cm] 2-3/4” Electrical 4” •Automatic, temperature compensated, pulse type charger •H igh capacity, automatic, dust-tight instantaneous transfer relay •L ow voltage disconnect prevents over discharge of battery • Automatic brownout protection • Battery lock-out prevents discharge during installation •S ealed maintenance free 3.6V Nickel-Metal Hydride battery •R ed charger monitor LED indicates charging of the battery •M omentary test switch allows for quick operational check of entire system 4” [10.16cm] 2-3/4” [5.08cm] Current (A) / Power (W) 120VAC, 60Hz 277VAC, 60Hz 0.191/0.92 0.129/1.62 Power Consumption Installation Model • Ceiling or wall mount •R ear keyhole slots and universal knock-outs to mount to any standard 4’’ junction box EL_2LEDR Listings • UL Listed to UL924 Listed • Damp location listing is standard (68º F to 86º F) Warranty • 3 year full warranty, excluding lamps and fuses How to Order SERIES EL LAMP OPTION _2LED= round LED array OPTIONS R= One double head dedicated remote Note: Remote capacity can only be used to power the EF43D or EF44D remote fixtures or to extend the battery units emergency run time beyond the standard 90 minutes. Example: EL_2LEDR 104 TYPE: DISTRIBUTOR SELECT CATALOG #: NOTES: ELXN400 LED Series Low energy and low maintenance for moderate budget application Features Dimensions Dimensions are approximate and subject to change. • Fully adjustable LED glare-free heads •3 .6V-3.6W long-life LED illumination with life expectancy of 50,000 hrs • Legend illumination by red or green long-life LEDs 4-2/8”4-2/8” [10.16cm] 7-2/8”7-2/8” [17.78cm] 8-2/8”8-2/8” [20.32cm] 17-7/8” 17-7/8” [43.18cm] Construction •F rame, faceplate, backplate and canopy are made of injection-molded, UV stabilized thermoplastic • UL94, 5VA flame rated body • Snap-together design • Corrosion and scratch-resistant of mist white color 11-5/8” [27.94cm] 11-5/8” Electrical • 3.6V Nickel-Metal Hydride battery • Dual-voltage input capability 120/277VAC • Self-diagnostics is not available 2” [5.08cm] 2” Power Consumption Installation Current (A) / Power (W) Model • Surface mount ceiling or wall • Canopy included for ceiling installation •B ackplate features universal knockouts for a standard 4’’ junction box, used in wall mount applications Listings 120VAC, 60Hz 277VAC, 60Hz ELXN400R-2LEDR 0.044/3.56 0.037/4.06 ELXN400G-2LEDR 0.042/3.2 0.036/3.8 How to Order - Combination Unit • UL Listed to UL 924 Listed • Damp location listing is standard (68°F to 86°F) •N FPA101 (Life Safety Code), NFPA70 NEC and OSHA illumination standard SERIES ELXN400= ELX Combo Series Warranty • 3 year full warranty, excluding lamps and fuses LEGEND COLOR R= Red exit G= Green exit LAMP OPTIONS -2LED= Round LED array R= One double head dedicated remote Example: ELXN400R-2LED EF43D & EF44D Series Dedicated Indoor and Outdoor Remote Emergency Lighting Dimensions Features Dimensions are approximate and subject to change. • Plastic housing and high output LED lamp source only available in 2-heads configurations • Can only be powered from the EL-2LEDR battery or ELXN400-LEDR Combo exit unit • 3 year full warranty • EF43D is for remote indoor applications; draws 3.6V-3.36W • EF44D is for remote outdoor applications; draws 3.8W 2-1/16” 4-1/6” 6-11/16” SERIES EF43= Indoor series EF44= Outdoor weatherproof series NO. OF HEADS D= 2 LAMP -LED= round LED array 5.63” [14.31cm] How to Order - Remote Heads OPTIONS Blank= Indoor remote WP= Outdoor weather proof remote 4.53” [11.13cm] Example: EF43D-LED 105 7.38” [18.74cm] DISTRIBUTOR SELECT TYPE: CATALOG #: NOTES: DLM-2 Series Thermoplastic Housing 6V-12W Capacity Lead-Calcium Battery Unit Standard Features Dimensions Dimensions are approximate and subject to change. •E ach self-contained unit comes with two (2) 6V high intensity glass wedge based incandescent lamps. •C onstructed of high-impact UL recognized 94V 5VA thermoplastic. Resists denting, peeling, scratching and corrosion. Transparent polycarbonate lens. •S ealed, maintenance-free Lead-Calcium batteries. • Integrated circuitry offers 120/277VAC 0.08/0.04A standard, automatic charging, instantaneous transfer, test switch, long life LED AC charge monitor light, temperature compensated charger, short-circuit proof and reverse polarity protected. Low battery voltage disconnect, brownout protection, and lockout (automatic battery connection). •C an be mounted in any orientation on walls or ceilings. No screws or other mounting hardware is visible. •L isted to UL 924 Standard. Complies with NEC, Life Safety Code and OSHA. •3 -year full warranty, excluding lamps, pilot lamps and fuses. • Damp location standard. 12” 2-3/4” Performance In both mechanical and electrical performance, the DLM-2 is a superior value in its class. 5” Its tough thermoplastic body and flush mounted heads will not dent, peel or corrode. The snap-together lens and body and self-connecting power plug make installation quick and easy. Electrical performance is assured by a 6 volt maintenance-free Lead-Calcium battery and a solid state charger with premium features such as: lockout, Temperature compensation, and low voltage disconnect. Selectable 120/277 standard operation. Power Consumption/Unit Rating Self-connecting power plug Snap-on housing Series Battery Type DC Voltage Watts to 87-1/2% of rated battery Units Dual Current voltage* Voltage* Maximum 1-1/2 hrs 2 hrs 3 hrs 4 hrs DLM-2 LeadCalcium 6V 12 – – * Stand-by power consumption is 50% lower for Lead-Calcium batteries. Accessories (order as a separate item) PART NUMBER DESCRIPTION Wire Guard WG3-E How to Order SERIES DLM-2= DLM-2 Battery-Powered Emergency Lighting Example: DLM-2 106 – 120VAC 277VAC 08A .04A TYPE: DISTRIBUTOR SELECT CATALOG #: NOTES: GS Series Recessed Gimbal 6V up to 18W Capacity Lead-Calcium or Nickel-Cadmium Battery Unit Features Dimensions Dimensions are approximate and subject to change. •A n adjustable gimbal directs the light from one (1) 6 volt 10 watt wedge-base PAR 36 lamp head. •T he low-profile trim ring is molded in polycarbonate with a semi-gloss white finish to complement a variety of ceilings. The fully recessed back box is constructed of 20-gauge steel. •C ontains a sealed, maintenance-free Lead-Calcium battery. •A slide out chassis and two quick-connect plugs make installation and servicing easy. Adjustable bar hangers included. •U L Listed. Complies with NEC, Life Safety Code and OSHA. •3 -year full warranty, excluding lamps, pilot lights and fuses. 14” to 24” 7” 10-1/4” Accessories (order as a separate item) SUFFIX DESCRIPTION Remote Test Switch (metal face plate) RTS-S Remote Test Switch (plastic face plate) RTS-1 Unit Rating 6-1/2” UNIT EQUIPMENT - NO REMOTE CAPABILITY Sealed Maintenance-Free Battery Types Lead-Calcium D.C. Voltage Model Number 6 GSM10-BH Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 3 hrs 4 hrs 10 – – – 7-3/4” * Stand-by power consumption is 50% lower for Lead-Calcium batteries. 8-1/2” How to Order SERIES GS= 6V series BATTERY/WATTAGE TYPE M10= Lead calcium 10W OPTIONS -BH= Bar hangers Example: GSM10-BH 107 DISTRIBUTOR SELECT TYPE: CATALOG #: NOTES: EL-2SQ Series Thermoplastic Housing 6V up to 23W Capacity Lead-Calcium Battery Unit Features Dimensions Dimensions are approximate and subject to change. •T wo (2) fully adjustable glare-free 6V-5.4W DC T5 wedge base lamps for emergency mode egress light. • Injection-molded UV stabilized thermoplastic housing and back plate. UL 94 Liste, 5VA flame rated. •S ealed, maintenance-free Lead-Calcium batteries. Designed to power 11 watts remote load or extended unit run time. •1 20/277 VAC dual voltage operation. LED indicator light and push button test switch. Remote capacity may power additional remote heads (up to 6V-11W). Low voltage battery disconnect. • Innovative, snap-together design allows for fast installation. Wall or ceiling mounting. Universal knock-out pattern on the back plate allows for junction box mounting. •U L Listed. Complies with NEC, Life Safety Code and OSHA. Damp location listing is standard in all models. •3 -year full warranty, excluding lamps and fuses. 12-1/4” 4-3/8” 5-1/8” Accessories (order as a separate item) SUFFIX DESCRIPTION Replacement battery 860.0018-E Replacement lamp (standard) 570.0012-E Vandal shield VRS.BB Vandal shield (NEMA 4X) VRSBB.4X Wire Guard (heads in any position) WG10-E 16-1/4” Unit Rating Series EL-2SQ Battery Type Lead-Calcium EL-2SQR Watts to 87-1/2% of rated battery voltage* DC Voltage 1-1/2 hrs 2 hrs 3 hrs 4 hrs 6V 12 – – – 6V 23 16 – – Units Dual Voltage* Current Maximum 120VAC 277VAC * National Electrical Code Specification How to Order SERIES EL= Self-Powered LIGHT HEADS -2SQ= Standard lamp 6V-5.4W Incandescent CAPACITY INDICATOR Blank= No remote capacity R= 11 watts remote capacity* * Do not exceed rated unit capacity. Example: EL-2SQR 108 08A .04A TYPE: DISTRIBUTOR SELECT CATALOG #: NOTES: ELX400 SQ Series Thermoplastic Combination Units and Remote Capacity Exit Sign Standard Features Dimensions Dimensions are approximate and subject to change. •C omes with two fully adjustable glare-free SQ light heads for egress lighting, with two (2) 6V-5.4 watts DC T5 wedge base lamps. •L ow power consumption – LED lamps are operated in normal (AC input) and emergency (DC input) modes. • Injection-molded UV stabilized thermoplastic housing, faceplates, and canopy. UL 94, 5VA flame rating. Two faces, backplate, and canopy. •A vailable with a sealed, maintenance-free Lead-Calcium battery. Additional battery available for 12 watts remote load or extended unit run time (see How To Order). •1 20/277 VAC dual voltage operation. LED indicator light and push button test switch. Remote capacity exit with two heads may power additional remote heads up to 6 Volt, 12 watts. Remote capacity exit with no heads may power additional remote heads up to 6 Volt, 22 Watts. Low voltage battery disconnect. • Innovative, snap-together design allows for fast installation. Wall or ceiling mounting. Canopy snaps to housing with a twist-lock feature tightly securing the canopy to the housing. Replaceable directional chevron inserts are easily removed and reinserted. •U L Listed. Complies with NEC, Life Safety Code and OSHA. Damp location listing is standard on all models. •3 -year full warranty, excluding lamps, pilot lights and fuses. Combination Unit 6-5/16” Units with no heads: 10-1⁄8” x 13” 16-1/8” Canopy 15-5/8” 4-5/8” 5-7/8” 14-5⁄8” 10-1/8” 21-3⁄4” 21-5/8” 1” Remote Capacity Unit Accessories (order as a separate item) 13” SUFFIX DESCRIPTION Wire Guard (heads in any position) WG10-E Replacement battery 860.0004-E Replacement lamp 570.0012-E 10-1/8” * Do not exceed rated unit capacity. Power Consumption Chart DESCRIPTION 2-9/16” 120/277VAC, 60Hz maximum 0.11/0.05A Note: Heads move from side to top in field How to Order SERIES ELXN400 LEGEND R= Red G= Green LIGHT HEADS CAPACITY INDICATOR -0= Combo no heads* -2SQ= Lamp standard 6V-5.4W Blank= No remote capacity R= 12W remote capacity* * Only available with remote capacity AD and red legend *Do not exceed rated unit capacity Example: ELXN400R-2SQR-AD 109 OPTION Blank= No options -AD= Advanced Diagnostics (audible)* * Only available with remote capacity and red stencil DISTRIBUTOR SELECT TYPE: CATALOG #: NOTES: EL-2MRS & 12EL50-2MRS Series Completely Self-Contained or Heavy Duty Thermoplastic Battery Unit Features Dimensions Dimensions are approximate and subject to change. • Each self-contained unit comes with two (2) 6V MR16 halogen or LED lamps housed in adjustable, gimbal-type assemblies to provide clean, adequate lighting •H igh impact thermoplastic construction is UL recognized 94, 5VA •S ealed, maintenance-free Lead-Calcium batteries •R eliable integrated circuitry offers 120/277VAC 0.1/0.05A input standard, automatic charging, instantaneous transfer, test switch, long-life LED AC charge monitor, temperature compensated charger, short circuit protection, low battery voltage disconnect, brownout protection, and lock out (automatic battery detection during installation) •S nap-together thermoplastic housing facilitates mounting in any orientation •U L Listed. Complies with NEC, Life Safety Code and OSHA Damp location listing is standard •3 -year full warranty, excluding lamps and fuses EL-2MRS 3-3/4” 5-1/2” 12-1/8” Accessories (order as a separate item) EL-2MRS PART NUMBER DESCRIPTION Replacement MR16 lamp 6V-5W 580.0072-E Wire Guard WG13-E Replacement Battery 860.0004-E Replacement MR16 LED lamp 6V-4W 580.0097-E 12EL50-2MRS 5-7/8” Accessories (order as a separate item) 12EL50-2MRS 5-1/2” PART NUMBER DESCRIPTION Wire Guard WG13-E Replacement MR16 lamp 12V-4W LED 580.0093-E Replacement MR16 lamp 12V-12W Halogen 580.0080-E Replacement MR16 lamp 12V-20W Halogen 580.0064-E 12-1/8” Power Consumption: EL2MRS Series EL-2MRS EL-2MRS-LA Battery Type Lead-Calcium Watts to 87-1/2% of rated battery voltage DC Voltage 1-1/2 hrs 2 hrs 3 hrs 4 hrs 6V 12 – – – 6V 12 – – – Dual Voltage 120VAC 277VAC Current Maximum .1A .05A Power Maximum 7.5W 7.5W Power Consumption: 12EL50-2MRS Series 12EL50-2MRS Battery Type Lead-Calcium Watts to 87-1/2% of rated battery voltage DC Voltage 12V 1-1/2 hrs 50 2 hrs 32 3 hrs 25 4 hrs 16 Dual Voltage 120VAC 277VAC Current Maximum .21A .1A Maximum 23W 23W How to Order: EL-2MRS SERIES LAMP OPTION EL= Series -2MRS= 6V-5W MR16 -2MRS-LA= 6V-4W, MR16 LED Example: EL-2MRS-LA How to Order: 12EL50-2MRS VOLTAGE 12= 12 Volts SERIES EL CAPACITY (W) 50 Example: 12EL50-2MRS-MK 110 LAMP -2MRS-MK= 12V-12W Halogen (Standard) -2MRS-LG= 12V-4W, MR16 LED -2MRS-MG= 12V-20W Halogen TYPE: DISTRIBUTOR SELECT CATALOG #: NOTES: ELX-MRS Series Thermoplastic Exit Sign and Combination Unit Features Dimensions Dimensions are approximate and subject to change. •R ugged off-white thermoplastic construction •E ven illumination for excellent legibility •S nap-together design for quick and easy installation •U niversal mounting, complete with 2 faces, backplate, and canopy •R eplaceable knockout directional chevrons •E nergy efficient, long-life red or green LEDs •L isted to UL 924 Listed •C omplies with NEC, Life Safety Code and OSHA. •D amp location listing is standard on all models. •6 volt, sealed, maintenance-free Lead-Calcium battery •F ully adjustable, glare-free, 6 volt MR16 lamps •3 -year full warranty, excluding lamps and fuses •4 watt LED lamps available 4-1/16” Charger 12-7/8” •1 20/277VAC input •F ully automatic charger •T emperature compensated •B rownout protection •S hort circuit protected •L ow voltage battery disconnect •P ush to test switch •A C pilot light 11-3/4” Accessories (order as a separate item) SUFFIX DESCRIPTION Replacement MR16 lamp 6V-5W 580.0072-E Wire Guard Wall Mount WG6-E Power Consumption DESCRIPTION 120/277VAC, 60Hz 0.11/0.05A How to Order SERIES ELXN400 STENCIL FACE R= Red G= Green LIGHT HEADS -2MRSN= 6V-5W MR16 -2MRSN-LA= 6V-4W, LED MR16 Example: ELXN400R-2MRSN 111 DISTRIBUTOR SELECT TYPE: CATALOG #: NOTES: ELX Series Economical, Thermoplastic LED Exit Signs Features Dimensions Dimensions are approximate and subject to change. •R ugged off-white thermoplastic construction •E ven illumination for excellent legibility •S nap-together design for quick and easy installation •U niversal mounting, complete with 2 faces, backplate, and canopy •R eplaceable knockout directional chevrons •E nergy efficient, long-life red or green LEDs •L isted to UL 924 Listed • Complies with NEC, Life Safety Code and OSHA. •D amp location listing is standard on all models •3 -year full warranty, excluding lamps and fuses ELX Series Models AC-only exit signs, red or green Self-powered exit signs, red or green Self-Powered Emergency Models •R eplaceable, sealed Nickel-Cadmium battery •P rovides a minimum 90 minutes of continuous emergency illumination •E nergy star compliant •B atteries recharge per UL924 specifications • Consumes less than 5W 7-1/4” 11-13/16” Charger •1 20/277VAC input •F ully automatic •T emperature compensated •B rownout protection •S hort circuit protected •L ow voltage battery disconnect •P ush to test switch •A C pilot light 1-13/16” Accessories (order as a separate item) SUFFIX DESCRIPTION Wire Guard - Wall Mount WG1-E Ceiling or end mount WG5-E Power Consumption DESCRIPTION 120/277VAC, 60Hz maximum 2.5W How to Order SERIES ELX400= AC-only ELXN400= Self-Powered STENCIL FACE RN= Red GN= Green Example: ELXN400RN 112 TYPE: DISTRIBUTOR SELECT CATALOG #: NOTES: Quick Switch Series LED Replacement Lamps LED Retrofit Kits Dimensions Quick Switch Dimensions are approximate and subject to change. •Q uick and easy to install •A vailable with wide range of lamp bases for quick lamp to lamp replacement •H igh brightness LEDs •1 20 VAC only •T wo bulbs per pack 1-1/4” 15/16” 5-1/8” 4-3/4” 3-3/4” 3-3/4” Power Consumption (LED Exit Signs) Model AC Specs QS 120VAC 0.9W QS-F 120VAC 1.6W How to Order SERIES QS 7/8” 7/8” QS-C QS-I QS-B QS-M QS-F30 Candelabra Base Intermediate Screw Base D.C. Bayonet Base Medium Screw Base PL 5, 7 or 9 Watt Base BASE -C= Candelabra -I= Intermediate -M= Medium -B= Bayonet -F30= Compact fluorescent Example: QS-C Dimensions Dimensions are approximate and subject to change. 7/8” 9-1/4” LED Retrofit Kit – Standard Features 1-1/4” •E asiest to install in its class •C ompact size makes it ideal for virtually all exit signs •C an be retrofitted directly on fluorescent ballast •L ong-Life, energy-efficient red LED technology •A vailable with AC adaptor for all type of lamp sockets How to Order Power Consumption (LED Exit Signs) NOTE: Please consult your sales representative for Green LED option. SERIES LED-RX MODEL BASE -C= Candelabra -I= Intermediate -M= Medium -B= Bayonet -F= Compact fluorescent -120-HW= Hard wired -277-HW= Hard wired Example: LED-RX-C 113 AC SPECS LED-RX 120VAC 0.7W LED-RX-120-HW 120VAC 0.7W LED-RX-277 HW 277VAC 0.7W Table Of Contents 115 FPDL Series 116 FPS Series 117 FPS-R & FPS-T Series 118 FTS Series 119 ELMR-E Series 120 Emergency Ballasts Reference Chart 121 EMERGENCY BALLASTS EMERGENCY BALLASTS EMERGENCY BALLASTS TYPE: CATALOG #: NOTES: FPDL Series Fluorescent Emergency Lighting Ballasts Six models meet different application requirements: Dimensions Dimensions are approximate and subject to change. • FPDL-32 500 lumens emergency ballast operates with most 2’-4’ T8 linear fluorescent lamps and also with 28W T5 lamps •F PDL/U 1400 lumens emergency ballast operates with most 2’-4’ T8 and T5 linear fluorescent lamps and also with most 4-pin compact fluorescent lamps •F PDL13-42-N 650 lumens emergency ballast operates with most 13-42W 4-pin quad and triple tube fluorescent lamps with one or two lamps (max. 18W) 00 lumens emergency ballast operates with most 2’-4’ T8 and T5 • FPDL-28 7 linear fluorescent lamps •F PDL-10-26 650 lumens emergency ballast operates with most 10-26W 2-pin compact fluorescent lamps •F PDL-HL-N is a high-output emergency ballast capable of producing up to 3000 lumens Features •C ompatible with standard, energy-saving, dimming and electronic AC ballasts •C an be wired to operate with switched, un-switched or normally-off fixtures without affecting normal operation •S ealed, maintenance-free Nickel-Cadmium batteries •U pon failure of AC power, the FPDL-32 and FPDL10-26 models automatically switch to emergency mode, maintaining illumination of one lamp within the fixture. FPDL/U, FPDL13-42-N, FPDL-28 and FPDL-HL-N units will maintain operation of one or two lamps when switched to the emergency mode •W hen AC power is restored, the FPDL Series automatically returns the fluorescent lamps to normal operating mode and the solid state charger begins recharging the battery •S elf-contained in one compact housing for easy installation and maximum mounting flexibility •U L Listed for damp locations to Standard 924; complies with NEC, Life Safety Code and OSHA, and field installation •3 -year full warranty •E ach unit is fully computer tested Cabinet Size Dimensions c d FPDL-32 9-1/2” 10-1/8” b 1-1/8” 2-1/8” FPDL/U 13-3/4” 14-1/4” 1-1/8” 2-1/8” FPDL13-42-N 8-7/8” 9-3/8” 1-1⁄/” 2-3/8” FPDL-28 13-3/4” 14-1/4” 1-1/8” 2-1/8” FPDL10-26 8-7/8” 9-3/8” 1-1/2” 2-3/8” FPDL-HL-N 15-3/4” 16-1/4” 1-3/4” 5-1/2” a Power Consumption Series Accessories (order as a separate item) PART NUMBER DESCRIPTION External mounting kit includes wire bundle cover for external mounting (not needed for FPDL13-42-N, FPDL10-26 and FPDL-HL-N) EC6 Remote test switch comes with single gang plastic mounting plate (included in FPDL13-42-N and FPDL10-26) RTS-1 Charging Indicator Light Push Button Test Switch How to Order SERIES FPDL-32 FPDL-U FPDL13-42-N FPDL-28 FPDL10-26 FPDL-HL-N Example: FPDL-32 116 Lamp Operated in Emergency Mode* Emergency Illumination Time Lumens FPDL-32 1 lamp 2’-4’ (20W-40W) 90 minutes 500 FPDL/U 1 lamp 2’-8’ (20W-60W) or 2 lamps 2’-4’ (20W-32W) 90 minutes 1400 FPDL13-42-N 1 compact 4-pin (13W-42W) or 2 compact 4-pin (13W-18W) 90 minutes 650 FPDL-28 1 lamp 2’-4’ (20W-54W) or 2 lamps 2’-4’ (20W-32W) 90 minutes 700 FPDL10-26 1 compact 2-pin (10W-26W) 90 minutes 650 FPDL-HL-N - 1 lamp 2’-8’ or - 2 lamps 2’-4’ or - 1 compact 4-pin (18W-70W) or - 2 compact 4-pin (18W-32W) 90 minutes 3000 TYPE: EMERGENCY BALLASTS CATALOG #: NOTES: FPS Series Fluorescent Emergency Lighting Ballasts Seven models are offered to satisfy different applications requirements and lumen output: Dimensions Dimensions are approximate and subject to change. •F PS-500 and FPS-825 operate with most 2’-4’ T5 or T8 PL lamps. The FPS-825 also operates HO and 4 pin long compact fluorescent lamps from 40 through 55 watts. •F PS-540 operates T5 or T8 lamps, including HO and 4-pin long compact fluorescent lamps of 40-55 watts, with an initial output of up to 1300 lumens. Testing the FPS-540 is made easy with a one-piece indicator and test switch. Features •F PS-80 is offered with Nexus® wired and wireless monitoring system which includes Nexus® fluorescent emergency ballast as well as Nexus® (wired or wireless) communication modem •C ompatible with standard, energy-saving, dimming and electronic AC ballasts •C an be wired to operate with switched, un-switched or normally-off fixtures without affecting normal operation •S ealed, maintenance-free Nickel-Cadmium batteries •U pon failure of AC power, the FPS-500, FPS-825 and FPS-540 models automatically switch to emergency mode, maintaining illumination of one lamp within the fixture. FPS-80 units will maintain operation of one or two lamps when switched to the emergency mode •W hen AC power is restored, the FPS Series automatically returns the fluorescent lamps to normal operating mode and the solid state charger begins recharging the battery •S elf-contained in one compact housing for easy installation and maximum mounting flexibility •U L Listed to Standard 924; complies with NEC, Life Safety Code and OSHA •3 -year full warranty • Each unit is fully computer tested Accessories (order as a separate item) External mounting kit includes wire bundle cover for external mounting -R Damp Location listing -DL Remote test switch includes single gang chrome finished mounting plate RTS-1 Test switch kit for fluorescent -TBTS Test switch kit for FPS80D/Nexus® LPTS SERIES C D FPS-500 13-3/4” 14-1/4” 1-3/16” 1-3/16” FPS-825 17” 17-1/2” 13/16” 1-3/16” FPS-540 12-1/2” 13-1/8” 11/2” 2-1/4” FPS-80D 12-3/4” 12-3/4” 11/2” 2-3/8” FPS-80NEXUS-N 12-3/4” 12-3/4” 11/2” 2-3/8” Series Charging Indicator Light Push Button Test Switch Wire End Caps 500 Optional, order #EC54 FPS-825 1 lamp 2’-4’ 90 minutes 825 Optional, order #EC54 FPS-540 1 lamp 2’-4’ (40W-50W) Most 2’-4’ T5 or T8 and 40-55W 4 pin compact fluorescent 90 minutes 1300 Not required FPS-80D Most 2’ - 4’ single, bi-pin T8 & T12HO and VHO, including long compacts and 2’ - 4’ 14W to 54W T5 lamps 90 minutes 1100 Not required FPS80NEX-N Most 2’ - 4’ single, bi-pin T8 & T12HO and VHO, including long compacts and 2’ - 4’ 14W to 54W T5 lamps 90 minutes 1100 Not required FPS80NEXRF-N 117 Lumens 90 minutes OPTION SUFFIX Example: FPS-80D Emergency Illumination Time 1 lamp 2’-4’ External Mounting Kit * Including Nexus® communcation module Lamp Operated in Emergency Mode* FPS-500 How to Order FPS-80NEX-N* FPS-80NEXRF-N* B A Power Consumption PART NUMBER DESCRIPTION FPS-500 FPS-825 FPS-540 FPS-80D Dimensions Cabinet Size EMERGENCY BALLASTS TYPE: CATALOG #: NOTES: FPS-R & FPS-T Series Fluorescent Emergency Packs Features Dimensions Dimensions are approximate and subject to change. • All-metal construction with off white baked enamel finish and 3” pre-wired fixture whip •S ealed, maintenance-free Nickel-Cadmium, Long Life Lead, or Lead-Calcium batteries •D uring normal operation, when the AC line voltage is present, the fixture will fully illuminate by means of the regular ballast. While supplied with AC, the emergency ballast transforms AC into a low DC voltage to recharge the battery and maintain it fully charged •W hen the AC fails, a solid state voltage sensor instantly turns on a high frequency inverter which supplies one or two lamps in the fixture for a minimum of 90 minutes. Only FPS-T can run 2 lamps in a 2 or 4 lamp fixture. •A t the end of the rated time a low voltage sensor disconnects the battery to prevent over-discharging •W hen the AC returns, the inverter switches off and the battery begins to recharge •C harger circuitry offers 120/277VAC, 60 Hz., 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lockout (automatic battery connect). •3 -year full warranty •E ach unit is fully computer tested REMOTE (FPS-R) 3” 4-1/2” 20-7/8” T-BAR (FPS-T) 3-1/4” Accessories (order as a separate item) 7-1/4” PART NUMBER DESCRIPTION Remote test switch RTS-1 Available for installation where routine testing via the units standard integral test switch would be difficult due to either fixture location or inaccessibility. This option consists of a push button test switch and pilot light, mounted on a single gang switch plate plastic white Test switch and charging indicator on a single gang chrome mounting plate 23-3/4” RTS 4-5/8” Unit Rating REMOTE MOUNTED (FPS-R) Cabinets Series DESCRIPTION Lumens Battery Suffix Sealed Maintenance-Free Battery Types Number of lamps Remote: (external) mounts on top or beside fixture. #18 gauge steel, finish white baked enamel finish and pre-wired 3” flexible conduit fixture whip. FPS-R 720 C Nickel-Cadmium 1 T-Bar: mounts in T-Bar struts beside fixture. #18 Gauge steel, finish white baked enamel finish and mounting eyes for fixture suspension and a pre-wired 3” flexible conduit fixture whip. FPS-R 720 E Long Life Lead 1 FPS-R 720 M Lead-Calcium 1 FPS-R 1800 C Nickel-Cadmium 1 FPS-R 1800 E Long Life Lead 1 FPS-R 1800 M Lead-Calcium 1 Servicing: Backplate lifts off for full access to battery and input/output wires. How to Order SERIES FPS= Fluorescent series CABINET TYPE -R= Remote -T= T-Bar T-BAR MOUNTED (FPS-T) LUMENS -720= 720 lumens -1800= 1800 lumens BATTERY TYPE # OF LAMPS FPS-T 720 C Nickel-Cadmium 1 -C= Ni-Cd -E= Long life lead -M= Lead-Calcium -1= One lamp -2= 2 lamps* FPS-T 720 E Long Life Lead 1 FPS-T 720 M Lead-Calcium 1 FPS-T 1800 C Nickel-Cadmium 1 FPS-T 1800 E Long Life Lead 1 FPS-T 1800 M Lead-Calcium 1 FPS-T 720 C Nickel-Cadmium 2 FPS-T 720 E Long Life Lead 2 FPS-T 720 M Lead-Calcium 2 FPS-T 1800 C Nickel-Cadmium 2 FPS-T 1800 E Long Life Lead 2 FPS-T 1800 M Lead-Calcium 2 * Only available with FPS-T Example: FPS-T-720-M-1 118 TYPE: EMERGENCY BALLASTS CATALOG #: NOTES: FTS Series Emergency Transfer Switch for Generator Supplies Features Dimensions Dimensions are approximate and subject to change. •C ompatible with standard, energy-saving, dimming and electronic AC ballasts •U L Listed •W ill cold start and operate all specified lamps •G alvanized steel case •D ual Voltage 120/277V 60hz •A vailable in flex or non-flex configuration •M eets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements •5 -Year Warranty. See Warranty page for details. TOP LENGTH 8” SIDE MOUNTING CENTER 7.5” Advantages •F ull light output •A llows auxiliary generator power on a switched fixture. HEIGHT 1.125” END Lamps Operated WIDTH 1.18” Will operate any lamp in the designated circuit for the duration of the generator supply Technical Specifications Wiring Diagrams Input Voltage............................................................. (Dual) 120/277V, 60Hz Input Current................................................................................... 250 mA Maximum Switching Voltage: •3 A @ 120V •3 A @ 277V Circuit Protection •3 A on Control Input •3 A on Neutral and 120/277V Outputs TYPICAL BALLASTS/GENERATOR APPLICATION WHT/BLACK White BLK/ORG Black ORG (120V) Emergency Operation The FTS will operate any lamp type in the designated fixture for the duration of the generator supply White BLU/WHT Normal Common BLUE Normal Hot Neutral Yellow Yellow/White Configuration •F TS (no flex) •F TS-R (w/ flex) Neutral Generator Power Red LED Normal Power Indicator (Opt) TYPICAL DIMMING BALLASTS/GENERATOR APPLICATION WHT/BLK BLKORG How to Order -R= Remote -T= T-Bar Hot RED Generator Hot RED/WHT Generator Common Options CABINET TYPE Normal Power Hot Wall Switch Transfer Switch Emergency Panel Weight............................................................................................... 1.0 lbs. Approval ....................................................................................... UL Listed FTS= Flourescent series 1) Select Porper Voltage Lead. Cap Unused Leads BLK (120V) FTS TRANSFER SWITCH Initial Illumination The FTS will operate the designated lamp at full light output SERIES AC BALLAST LUMENS -720= 720 lumens -1800= 1800 lumens BATTERY TYPE # OF LAMPS -C= Ni-Cd -E= Long life lead -M= Lead-Calcium -1= One lamp -2= 2 lamps* WHT BLK Orange AC BALLAST Blue BLK/ORG Red FTS TRANSFER SWITCH RED/BLK RED/WHT YELLOW YELLOW/WHT ALL WHT White ORG (277V) BLK (120V) ORG (277V) 1) Select Proper Voltage Lead. Cap Unused Lead. BLK (120V) FTS TRANSFER SWITCH 2) Cap Unused Leads White Blue/Wht Blue Normal Hot Neutral Yel Red Emergency Panel Red Generator Hot RED/WHT Generator Common * Only available with FPS-T Yellow Yellow/White Example: FPS-T-720-M-1 119 Blk Hot Normal Power Normal Panel Hot Generator Neutral Power Red LED Normal Power Indicator (Opt) EMERGENCY BALLASTS TYPE: CATALOG #: NOTES: ELMR-E Interface Module Series Enables Normally-On Low Voltage (12V) Lamps To be Used as Emergency Lighting ELMR-E Unit Fixture Transformer 12V Lamp 12V Emergency Lighting Unit Application: To maintain the integrity of lighting decor, Emergi-Lite® offers an interface module, “ELMR-E”; which is designed to be incorporated with MR16, PAR36, R12, or R14 low voltage lighting fixtures that are being used as both normal lighting fixtures, and as emergency lighting fixtures. These dual-function fixtures are used in a variety of accent applications, especially in retail store lighting. Module Information The Emergi-Lite® “ELMR-E” interface module consists of a relay transfer panel enclosed in an octagonal electrical box which measures 4-1/2 inches in diameter by 3-5/8 inches deep. The module is designed to operate 12 volt lamps up to a total of 200 watts. A remotely located Emergi-Lite® 12 volt emergency lighting unit, in conjunction with the “ELMR-E”, supplies 12 volt during an emergency situation regardless if the fixture is switched on or off. * 12V NORMALLY-ON N AC INPUT L N # # # L FIXTURE TRANSFORMER (SUPPLIED BY OTHERS) X 12V LAMP X * GRY YEL RED Installation WHT BLUE The “ELMR-E” interface module is provided with a 1/2 inch threaded conduit nipple for fast, easy, field installation and mounts directly to the step-down transformer junction box of the low voltage lighting fixture. For applications requiring remote mounting, not only is a fixture “stud plate” is provided, as well as two mounting tabs with 3/16 inch diameter holes on 4-9/16 inch centers. Electrical connection is made by splicing to the secondary winding of the step-down transformer and connecting it and the remote feed from the 12 volt battery pack to the “ELMR-E” module. One “ELMR-E” is required for each fixture that contains an internally mounted step-down transformer. However, if several low-voltage lamps are assigned to a single, centrally-located step-down transformer, only one “ELMR-E” is needed to operate all lamp fixtures, up to 200W. BLK TO OTHER MODULES WITH FIXTURES ON SAME AC CIRCUIT L N 12 VOLT EMERGENCY LIGHTING UNIT } CONNECT TO DC OUTPUT LOAD TERMINALS Notes: X Denotes “Cut Original Wiring” *: “To other low-voltage lamps” (multiple-lamp, single transformer arrangements only) #: Install wall switch here, (if required) Operation IMPORTANT: Emergency lighting units must be fed from same branch feeder circuit (normally-on circuit) In the event of a power failure the 12 volt Emergi-Lite® battery unit would supply the “ELMR-E” module with 12 volt DC power. The “ELMR-E” module would then transfer the lighting fixture from its normal 12 volt AC source (transformer) to the 12 volt DC battery power. Upon restoration of the normal AC power supply, the module will transfer the lighting fixture back to its normal operating mode. Note: Remote battery pack must have sufficient capacity to support the connected load for a minimum of 90 minutes. Consult Emergi-Lite®’s technical data section for wire run length and wire size requirements. Emergency lighting unit must be capable of supplying total wattage lamp loads for a minimum of 90 minutes. Applications may require longer time durations. Consult NFPA Life Safety Code and National Electric Code and National Electric Code Article 700 with regard to standard engineering practices. Local codes may vary. 120 TYPE: NOTES: Reference Chart EMERGI-LITE® MODEL # Lumens FPDL-32 FPDL/U FPDL13-42 FPDL-28 500 1400 650 700 LAMP TYPE (# OF LAMPS) 2’-4’ Rapid, Instant, Energy Saving, T8 thru T12 (1) X 2’-8’ Rapid, Instant, Energy Saving, T8 thru T12, HO & VHO (1) X F25 T8 (2) F32 T8 (1) FPS500 FPS80D FPS825 FPS540 650 3000 500 1300 825 1300 X X X X X X X X X X X X X X X X X X X X F17 T8 (2) F25 T8 (1) FPDL-HL LINEAR LAMPS 2’-4’ Rapid, Instant, Energy Saving, T8 thru T12, HO & VHO (2) F17 T8 (1) FPDL10-26 X X X X X X X X X X X X X X X X X X F32 T8 (2) X X X F40 T8 (1) X X X FO96 T8 59W (1) X X X X X X X X X X X X 14W T5 (1) X X X X X X 21W T5 (1) X X X X X X X 24W T5 (1) X X X X X X X 28W T5 (1) X X X X X X X X X 39W T5 (1) 54W T5 HO (1) F20 T12 (1) X F20 T12 (2) F40 T12 (1) X F40 T12 (2) X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X F48 T12 (1) X X X F96 T12 60W (1) X X X LAMP TYPE (# OF LAMPS) 18W Long Compact (1) 24W Long Compact (1) 36W Long Compact (1) 40W Long Compact (1) 40W Long Compact (2) 50W Long Compact (1) 55W Long Compact (1) 7W PL CF 2-Pin (1) 9W PL CF 2-Pin (1) 13W PL CF 2-Pin (1) 18W PL CF 2-Pin (1) 26W PL CF 2-Pin (1) 13W PL CF 4-Pin (1 or 2) 18W PL CF 4-Pin (1 or 2) 26W PL CF 4-Pin (1) 26W PL CF 4-Pin (2) 32W PL CF 4-Pin (1) 32W PL CF 4-Pin (2) 42W PL CF 4-Pin (1) 42W PL CF 4-Pin (2) 57W PL CF 4-Pin (1) 57W PL CF 4-Pin (2) 70W PL CF 4-Pin (1) 20W Circline (1) 22W Circline T9 (1) 22W Circline T5 (1) 40W Circline T8 (1) 40W Circline T5 (1) 55W Circline T5 (1) F28 2D (1) F28 2D (2) F38 2D (1) F38 2D (2) COMPACT LAMPS X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 121 X X X X X X X X X X X X X X X X X X X X EMERGENCY BALLASTS Emergency Ballast Series CATALOG #: Table of Contents 123 Mini-Inverters 124-125 Emerg-Power Systems Feature & Benefits 126-127 Emerg-Power Compact Series 128-129 Emerg-Power IPS Single Phase Series 130-131 Emerg-Power FTC Single Phase Series 132-133 Emerg-Power 3FTC Three Phase Series 134 Emerg-Power FTC3R & 3FTC3R Series 135 Emerg-Power System Options 136 Emerg-Power Control Panel & Display Functions 137 Emerg-Power Central System Request Data 138 CENTRAL & INVERTER SYSTEMS CENTRAL & INVERTER SYSTEMS CENTRAL & INVERTER SYSTEMS TYPE: CATALOG #: NOTES: Mini-Inverter Series Interruptible Unit Equipment Highlights Suggested Specification The Mini-Inverter is a UL Listed stand-alone simulated sine wave output inverter designed to provide power to designated emergency lighting fixtures. In a power loss situation, it will supply power from the onboard battery supply. Emergency lighting shall be provided by inverter unit equipment designed to operate designated incandescent, fluorescent and LED fixtures on emergency power at their full nominal lumen rating during the full 90 minutes emergency discharge cycle. System output will be rated at watts for 90 minutes and provide used output connections to the load. The system’s voltage rating shall be VAC input/output. The inverter unit shall allow for connected emergency fixture(s) to be normally on, normally off, switched or dimmed without affecting lamp operation during a power failure. Upon utility power loss, the inverter unit shall deliver 100% of its rated output to the emergency fixtures regardless of the local switch or dimmer position, and will provide power to emergency fixtures at distances of up to 1000 feet. The housing shall be manufactured using 14-gauge steel with a white baked-on powder coat paint finish. The unit’s electronics shall include a self-contained inverter section with a fully automatic, thermal-compensating variable-rate battery charger, AC lockout feature, low voltage battery disconnect, DC overload, short circuit and brownout protection as standard. The unit shall utilize a sealed lead calcium batter y with a 10-year design life. The inverter system shall be UL 924 Listed and labeled. The unit shall be covered under a 3-year warranty on the electronics and battery and a 7-year pro-rata warranty on the battery. The Mini-Inverter works in conjunction with incandescent, LED, and fluorescent fixture types and will automatically run switched, normallyon, or normally-off designated emergency fixtures. The Mini-Inverter is ideal for applications requiring an emergency source for lighting arrangements that utilize multiple lamp and fixture types and is available in surface mount and comes with a one year warranty and nine-year pro-rata battery warranty. Features • Lamps operated: Incandescent LED, fluorescent lamps and ballast combinations, including dimming ballasts • Components: High-efficiency pure sine wave inverter, temperaturecompensated charger 12V oversized Valve Regulated Acid (VRLA) battery • Construction: 14-gauge steel housing • Emergency lighting supplied from one convenient source • Input/Output voltage 120V 60 Hz or 277V 60 Hz • Replacable output fuse protection • Line voltage allows for remote mounting of emergency fixtures at distances up to 1000 feet • Low Voltage Battery Disconnect • Unit comes standard with electronic lockout and brownout circuits • Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements • Cabinet in factory white semi-gloss powder-coat paint finish • May accept load to it’s full capacity when load feature power factor of 0.9 or more • Optional auto-diagnostic available, including Nexus system interface with an improved minimum load lost detection of 10% Specifications Transfer Time less than 1 second Voltage Regulation on Emergency +/- 3% Frequency Regulation on Emergency 60 Hz +/- 1% Load Power Factor Range .9 leading to .9 lagging Operating Temperature 68° to 86°F (20° to 30°C) Warranty All Emergi-Lite® inverter products receive 100% quality inspection before shipment to insure proper and satisfactory operation. When operated under normal conditions, Emergi-Lite® inverter products will provide years of dependable service. This unit is backed by a 3/7 year warranty. The unit is covered by a complete 3-year warranty against defects in material or workmanship, and a 7-year prorata battery warranty. The inverter unit shall be Emergi-Lite® model: ! NEW Electrical Characteristics & Dimensions POWER RATING SINE WAVE INSTALLATION CABINET DIMENSIONS W” H” D” NO. OF BATTERY WEIGHT WEIGHT W/O BATTERY 120V & 277V 120V & 277V 125W Modified T-Bar 24” 6.5” 8” 1 43 lbs 20 lbs 125W Modified Wall 16.5” 12.2” 7.3” 1 41 lbs 18.5 lbs 250W Pure Wall 27” 12.2” 7.3” 2 76 lbs 30 lbs 400W Pure Wall 24” 10.5” 20” 2 128 lbs 50 lbs 720W Pure Wall 24” 14.5” 20” 2 185 lbs 72 lbs 124 TYPE: CENTRAL & INVERTER SYSTEMS CATALOG #: NOTES: Mini-Inverter Series Interruptible Unit Equipment Wiring Diagram 1RUPDO IL[WXUH (PHUJHQF\ IL[WXUH 1RUPDO IL[WXUH 9DFVZLWFKHG &20021 &20021 Common 9DF6:,7&+('+27 HOT 120V +279 9DF6:,7&+('+27 EMERGENCY ONLY 277V 85*(1&<9 9DF (PHUJHQF\ IL[WXUH 9DF 9DF816:,7&+('+27 5HOD\&75/ &KDUJHU 9DF816:,7&+('+27 ,QYHUWHU &75/ ,QYHUWHU %DWWHU\ 1RUPDO IL[WXUH (PHUJHQF\ IL[WXUH 1RUPDO IL[WXUH 9DF &20021 9DF (PHUJHQF\ IL[WXUH 9DFVZLWFKHG &20021 Common 9DF6:,7&+('+27 HOT 120V 85*(1&<9 9DF6:,7&+('+27 EMERGENCY ONLY 277V +279 9DF816:,7&+('+27 5HOD\&75/ &KDUJHU 9DF816:,7&+('+27 ,QYHUWHU &75/ ,QYHUWHU %DWWHU\ 3URSRVDO,QVWDOODWLRQ8(,B5HY How to Order SERIES EMIU BATTERY TYPE/CAPACITY -125= 125W -250= 250W -400= 400W -720= 720W VOLTAGE -MT= (120/120 or 277/277)* OPTIONS -NEX= Nexus® wired -NEXRF= Nexus® wireless -D3= Time Delay (15 minutes) -T= Recessed T-Bar mounting (125W unit only) -AD= Advanced-Diagnostic, audible* -ML= Mix normally on and off loads -SAC= Service Alarm Contact** * Minimum load required: 10% of unit capacity ** Not available with 720 capacity Example: EMIU-720-1 125 CENTRAL & INVERTER SYSTEMS EMERG-POWER SYSTEMS Features & Benefits Highlights APPLICATIONS PERFORMANCE merg-Power Systems can be used in almost every type of building, and are E well-suited for architecturally sensitive applications or areas where maintenance costs and individual testing of unit equipment becomes significant. Emerg-Power Systems are designed to work with power factor corrected as well as the most recent T5 and T5-HO electronic ballasts. Emerg-Power Systems work with any type of lighting load to provide full light output for a minimum of 90 min. They are designed to support incandescent, fluorescent, HID*, quartz re-strike, LED or halogen lamps. They will work to power into these loads at cold starts for all normally off circuits or normally on circuits. * Except IPS systems OPTIONS he full range of options available, such as integrated output circuit breakers, T bypass relays, dry contacts, etc., makes Emerg-Power Systems an industry leader in emergency lighting central systems. TRUE SINE WAVEFORM sing a solid-state, pulse width modulation (PWM) inverter the systems U produce pure sinusoidal output waveform with less than 3% maximum Total Harmonic Distortion (THD) for linear loads. Microprocessor and crystal controlled. RELIABILITY merg-Power Systems use third generation inverter technology. The proven E solid design and double ratings of all critical components. LVD (Low Voltage Disconnect) for long power outages eliminates battery drain. BATTERIES ront access connections for easy installation significantly reduce the footprint, F installation and maintenance time while increasing safety. Automatic restart and recharge upon restoration of utility. APPROVALS L listed to UL924. Meets UL 924 Listed, NFPA101, NFPA70, NFPA 110, U OSHA, UBC, SBCCI. New York City approved. System type Compact Series 1PH IPS 1PH FTC 3PH FTC Outdoor 1 PH FTC Outdoor 3 PH FTC 500VA 1500VA 2000VA 3KVA 4KVA 4.8KVA 8KVA 16.7KVA 50KVA Capacity (KVA=KW) 126 Features & Benefits Features Benefits SELF-DIAGNOSTIC/SELF-TESTING COMPLIANCE WITH NFPA101 •P rogrammable monthly and annual self-testing. Proven self-diagnostic with over 120 parameters stored in separate memory logs for Test, Event and Alarm. • Microprocessor monitoring and control. •S elf-testing meets the requirements of NFPA and UL. User programmable time of testing. •T est results, events and alarms can be downloaded from history logs. Load monitoring. Reduced testing/service time. LOW HEAT DISSIPATION LESS AIR-CONDITIONING •V ery low heat loss technology in normal operating mode (see specifications for exact values). Convection cooling in normal mode with forced air during emergency mode. • Battery cabinets: convection cooling only. •R educed costs for air-conditioning required to ensure the optimum operating temperature when compared with equivalent systems that dissipate much more heat. • Higher reliability of fans and the electronic components. MAXIMUM EFFICIENCY LOWER ENERGY BILLS •H ighest efficiency in the industry, 98% at 100% load with no requirement for cooling in normal operating mode. • Low input harmonic distortion <10%. •L ow consumption of the system itself will result in lower energy bills paid over the system life time. Comparative analysis available on request. VERSATILE INSTALLATION EASY TO INSTALL •M odular design, easy front access freestanding cabinets, fasten together when more than one cabinet is required. • Optional seismic kit available. •A ll wiring provided is pre-cut and terminated, along with the necessary hardware and electrical fittings, for proper installation. •Q uick installation and connection through flexible cable entries and fast access terminal blocks. •R educed footprint for systems with stackable cabinets. •L ow MTTR (<15 min.) due to modular design, quick disconnect means and frontal access. COMPLETE PROTECTION REDUCED DAMAGE RISKS • Input circuit breaker and fused battery circuit are standard. •S ystems offer overload capacity, short-circuit protection, current-limiting, low-battery disconnect, reverse polarity and brownout protection as standard. •F ull system protection eliminates damage created by external events and increases the lifetime of the electronics and batteries. Also will provide safety during maintenance. THERMAL PERFORMANCE INCREASED MTBF •B onded fin heat sink technology for maximum thermal performance. • Cooling fans are energized only in inverter mode. • Increased reliability and reduced preventative maintenance. • No air filters needed. MONITORING AND CONTROL EASY MAINTENANCE •U ser-friendly programmable interface with LED indicators and LCD display provides full metering values, easy program and control functions and a wide range of visual and audible alarms. •E asier diagnostic, troubleshooting, preventative maintenance and service through the indicators and display or by using the history logs. • Remote versions available. 127 CENTRAL & INVERTER SYSTEMS EMERG-POWER SYSTEMS CENTRAL & INVERTER SYSTEMS Emerg-Power Systems Compact Series Features • 98% efficient at full load • PWM/MOSFET technology • Self-testing/Self-diagnostic • User programmable with password protection • Standard input circuit breaker • Standard output circuit breaker • Micro-processor controlled • Floor or wall mountable • Field upgradeable (500VA steps) • 90 min. standard run time • Electronic and magnetic ballast compatible • Automatic event, test and alarm log • LCD display • Small footprint (stackable cabinets) • Maintenance-free standard batteries • Forced air cooling during emergency mode only UL listed to UL924. Meets NFPA101, NFPA70, NFPA 110, OSHA, UBC, SBCCI. N.Y City approved. Electrical/Mechanical Characteristics4 (data provided for standard Lead Calcium batteries)1,4 BATT. VDC 277V HEAT LOSS IN NORMAL MODE (BTU/HR) 5.2 2.3 34 48 13.5 4 26 10 98 10.5 4.5 68 48 26.5 8 26 1500 98 15.6 6.8 102 48 40 12 2000 98 20.8 9 136 48 52 16 EFFIC. AT FULL LOAD % MAX. INPUT CURRENT (A) 120V 500 98 1000 POWER RATING1 VA= W 1 2 UPS CABINET DIMENSIONS BATTERY CABINET NO. OF DIMENSIONS2,3 BATT CAB. W” H” D” BATT. CAB. WEIGHT LBS UPS CAB. WEIGHT LBS BATT. WEIGHT LBS TOTAL SYSTEM WEIGHT LBS 10 26 10 10 1 22 lbs 77 lbs 107 lbs 206 lbs 10 10 26 10 10 2 22 lbs 77 lbs 214 lbs 335 lbs 26 10 10 26 10 10 3 22 lbs 77 lbs 321 lbs 464 lbs 26 10 10 26 10 10 4 22 lbs 77 lbs 428 lbs 592 lbs BATT. NO. OF A BATT. W” S ystem capacity can be upgraded in the field up to 2000VA by adding more battery cabinets. Re-programming required by factory service technician. Batteries are installed in separate modular cabinets 3 4 H” D” Battery cabinets are stackable. Must be installed under the electronics cabinet Special voltages can change the size, weight or number of cabinets How to Order INPUT VOLTAGE* 120 277 BATTERY TYPE SG= Lead-Calcium SYSTEM TYPE VA/W 500 1000 1500 2000 -FTCM * Special voltages may change the size, weight or number of cabinets OUTPUT VOLTAGE* -120 -277 * Special voltages may change the size, weight or number of cabinets RUN TIME* -90 * Other run times available Example: 120SG1500-FTCM-120-90-ICB-OCB0420-WB 128 INPUT BREAKER -ICB OUTPUT BREAKERS* -OCBxxxx= No trip alarm* -OCAxxxx= With trip alarm* * Max. 3 more additional output breakers for a total of 4. See page 137 for output breakers details. OPTIONS* -NOFF= Normally OFF output -WB= Wall mount bracket -DCS= Dry summary alarm contacts -INVON= Inverter on dry contact -VTD= Variable time delay -BPR= Bypass relay -RMP= Remote metering panel -RSAP= Remote summary alarm panel -RS232= Communication interface -MOD= Modem -FLR= Floor blanket * See page 137 for options description TYPE: CENTRAL & INVERTER SYSTEMS CATALOG #: NOTES: Uninterruptible Emergency Lighting, 1PH, Inverter System 500VA – 2000VA System Specifications GENERAL Design Stand-by no break. PWM inverter type utilizing MOSFET technology with 2ms transfer time Control • Microprocessor controlled, 2 x 20-character display with touch pad controls & functions • 5 LED indicators & alarm with ring-back feature Metering Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Temperature, Inverter Wattage Communications Optional RS-232 port (DB9) CABINETS Modular design, freestanding or wall mount NEMA Type 1 steel cabinets powder coated for corrosion and scratch resistance. Front access design. Cabinets are stackable. Top and left side conduit entry with knockouts. INVERTER Using MOSFET/PWM technology the inverter converts the DC voltage supplied by the batteries to AC voltage of a precise stabilized amplitude and frequency, suitable for most sophisticated electrical equipment. True sinusoidal output waveform with very low distortion (less than 3% for linear loads). Overload capability of up to 150% for 12 line cycles. ELECTRICAL INPUT CHARGER Fully automatic, temperature compensated, microprocessor controlled charger recharges fully discharged batteries in maximum 24 hours at nominal AC input voltage. AC input current limiting and over-voltage protection included. Voltage 120 or 277VAC, 1-phase 2-wire, +10%/ -15% Contact factory for all other voltage. Input Power Walk-In Limiting inrush current to less than 125%, 10 times for 1 line cycle Input Frequency 60Hz, +/-3Hz Protection Standard Input Circuit Breaker Harmonic Distortion <10% System is provided with 10 year, maintenance free, sealed valve regulated LeadCalcium batteries. 90 min. standard discharge time at full load under normal operating temperature. Low Voltage Disconnect protection included. No special ventilation required. Power Factor 0.5 lag/lead SELF-DIAGNOSTIC BATTERY Automatic self-test consists of a 5-minute monthly and 90-minute annual function. The front-mounted control panel includes 5 LED indicators, a 2-line 20-character LCD display, a keypad to control and monitor the internal operation of the system. This allows the operator to easily “watch” system functions as they occur and check on virtually any aspect of the system’s operation. Self-diagnostic function monitors, controls, generates alarms and memorizes events. ELECTRICAL OUTPUT Voltage 120 or 277VAC, 1-phase 2-wire Contact factory for all other voltage. Static Voltage Load current change +/-2%, battery discharge +/-12.5% Dynamic Voltage +/-2% for +/-25% load step change, +/-3% for a 50% load step change, recovery within 3 cycles Harmonic Distortion <3% THD for linear load Output Frequency 60Hz +/- 0.05Hz during emergency mode Load Power Factor 0.5 lag to 0.5 lead Inverter Overload 115% for 5 minutes Protection Standard Output Circuit Breaker (normally on) Crest Factor 2.8 ALARMS High/Low Battery Charger Voltage, High/Low AC Input Voltage, Near Low Battery, Low Battery, Load Reduction Fault, Output Overload, High Ambient Temperature, Inverter Fault, Output Fault, Optional Output Circuit Breaker Trip OPTIONAL FEATURES Normally OFF output, Output Circuit Breakers, Output Trip Alarm, RS232 communication port, 12 Hours Fast Recharge, Remote Meter Panel, Remote Summary Alarm Panel, Summary Alarm Dry Form C Contact, Inverter on Dry Contacts, Variable Time Delay, Modem, Bypass Relays, Wall mount bracket FACTORY START-UP Includes one additional year of warranty. See warranty conditions. ENVIRONMENTAL CONDITIONS Storage/Transport • -4ºF to 158ºF (-20ºC to 70ºC) without batteries • 0ºF to 104ºF (-18ºC to 40ºC) with batteries (max. 3 months at 104° F (40° C) Operating Temperature System operates safely from 32°F to 104°F (0°C to 40°C) but optimum operation is between 68° F and 86°F (20°C to 30°C). Battery performance can be affected by temperature Altitude <10,000 feet (above sea level) without de-rating Relative Humidity 0 to 95% non-condensing Audible Noise 45 dBA @ 1m from surface in emergency mode WARRANTY (full limited warranty conditions available upon request) Limited manufacturer warranty is one-year, parts and labor, for system electronics or two-year with factory start-up program. Battery warranty is one year full plus 9 years pro-rata for a total of 10 years, under normal operating conditions. System must be put in service within 180 days from ship date in order to validate warranty. SINGLE LINE DIAGRAM NORMAL EMERGENCY Characteristics, specifications and dimensions subject to change without notice. 129 CENTRAL & INVERTER SYSTEMS Emerg-Power Systems IPS Single Phase Series Features • 98% efficient at full load • PWM/IGBT technology • Self-testing/Self-diagnostic • User programmable with password protection • Standard input circuit breaker • Standard Normally Off and on output • RS232 communication port • Micro-processor controlled • Automatic event and alarm log • 90 min. standard run time • Generator compatibility • Electronic and magnetic ballast compatible • Custom voltages available • Automatic event, test and alarm log • LCD display • Reduced footprint (stackable cabinets) • Maintenance free standard batteries • Forced air cooling during emergency mode only Electrical/Mechanical Characteristics4 UL listed to UL924. Meets NFPA101, NFPA70, NFPA 110, OSHA, UBC, SBCCI. N.Y City approved. (Data provided for standard Lead Calcium batteries) 1, POWER RATING1 KVA= KW 1.5 2.25 3 3.75 5 6 8 10 12.5 16.7 1 2 MAX. INPUT CURRENT (A) EFFIC. AT FULL LOAD % 98 98 98 98 98 98 98 98 98 98 120V 16 24 32 39 50 63 84 105 131 174 277V 7 11 14 17 22 27 36 45 57 76 HEAT LOSS IN NORMAL MODE (BTU/HR) 102 153 204 255 340 408 544 680 850 1136 BATT. VDC UPS CABINET DIMENSIONS BATT. NO. OF A BATT. W” 48 72 96 120 144 180 240 144 180 240 39 38 38 37 40 40 39 82 82 80 4 6 8 10 12 15 20 24 30 40 30 30 30 30 30 30 30 30 30 30 C onsult factory for 20 year type batteries or for wet nickel cadmium batteries. Batteries are installed in the electronics cabinet for 1.5 to 5kVA systems 3 4 H” 47 47 47 47 47 47 47 47 47 47 D” 25 25 25 25 25 25 25 25 25 25 BATTERY CABINET NO. OF DIMENSIONS2, 3 BATT CAB. W” H” D” NA NA NA NA NA 30 30 30 30 30 NA NA NA NA NA 47 47 47 47 47 NA NA NA NA NA 25 25 25 25 25 NA NA NA NA NA 1 1 2 2 2 BATT. CAB. WEIGHT LBS (EMPTY) UPS CAB. WEIGHT LBS NA NA NA NA NA 210 lbs 232 lbs 420 lbs 420 lbs 464 lbs 250 lbs 265 lbs 295 lbs 305 lbs 315 lbs 350 lbs 375 lbs 435 lbs 465 lbs 530 lbs BATT. WEIGHT LBS 296 lbs 444 lbs 592 lbs 740 lbs 888 lbs 1110 lbs 1480 lbs 1776 lbs 2220 lbs 2960 lbs TOTAL SYSTEM WEIGHT LBS 546 lbs 709 lbs 887 lbs 1045 lbs 1203 lbs 1670 lbs 2087 lbs 2631 lbs 3105 lbs 3954 lbs Battery cabinets are stackable. To be installed on the right side of the electronics cabinet Special voltages or batteries may change the size, weight or number of cabinets How to Order INPUT VOLTAGE* 120 208 240 277 * Special voltages may change the size, weight or number of cabinets BATTERY TYPE SG= Sealed Lead-Calcium NC= Wet Ni-Cd VA/W RATING 1500 2250 3000 3750 5000 6000 8000 10000 12500 16700 SYSTEM TYPE -IPS OUTPUT VOLTAGE* -120 -277 -208 -120/140 -120/277 * Special voltages may change the size, weight or number of cabinets RUN TIME* -90 INPUT BREAKER RS232 PORT -ICB -RS232 OUTPUT BREAKERS* OPTIONS* -OCBxxxx = no trip alarm* -OCAxxxx = with trip alarm* -20Y= 20 yr sealed batteries -12HR= 12 hr fast recharge -MBYP= Internal bypass switch -EMBP= External bypass switch** -RMP= Remote metering panel -RSAP= Remote summary alarm panel -DCS= Dry summary alarm contacts -INVON= Inverter on dry contacts -VTD= Variable time delay -MOD= External modem -FAX= Fax modem -BPR= Bypass relays -DIAL= Autodialer -SEIS= Seismic mounting -ZONEM= Zone monitoring -BATM= Battery cycle warranty monitor * Max. 12 unsupervised single pole positions or 8 with trip alarm. For more output breakers please consult factory. See page 137 for output breakers option details. * Other run times available Example: 277SG6000-IPS-277-90-ICB-RS232-OCB0420-DCS-20Y 130 * See page 137 for options description ** External bypass switch is not compatible with integrated output circuit breakers. Input/output voltage has to be the same. TYPE: NOTES: Interruptible Emergency Lighting Inverter System 1.5Kva –16.7Kva System Specifications GENERAL Design Stand-by. PWM inverter type utilizing IGBT technology with 50ms transfer time. Control • Microprocessor controlled , 2 x 20-character display with touch pad controls & functions • 5 LED indicators & alarm with ring-back feature Metering Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Temperature, Inverter Wattage Communications RS-232 port (DB9) CABINETS Modular design, freestanding NEMA Type 1 steel cabinets powder coated for corrosion and scratch resistance. Front access design through hinged lockable doors requires only 39” front clearance and 12” top clearance. Cabinets are stackable if required to further reduce the footprint. Top and left side conduit entry with knockouts. INVERTER Using IGBT/PWM technology the inverter converts DC voltage supplied by the batteries to AC voltage of a precise stabilized amplitude and frequency, suitable for most sophisticated electrical equipment. True sinusoidal output waveform with very low distortion (less than 3% for linear loads). Overload capability of up to 150% for 12 line cycles. ELECTRICAL INPUT Voltage 120 or 277VAC 1-phase 2-wire +10% - 15%. Contact factory for all other voltages Input Power Walk-In Limiting inrush current to less than 125%, 10 times for 1 line cycle Input Frequency 60Hz, +/-3%, 50Hz available upon request Protection Input circuit breaker Harmonic Distortion <10% Power Factor 0.5 lag/lead CHARGER Fully automatic, temperature compensated, microprocessor controlled charger recharges fully discharged batteries in maximum 24 hours at nominal AC input voltage. AC input current limiting and over-voltage protection included. BATTERY System is provided standard with 10 year, maintenance free, sealed valve regulated, front terminals Lead-Calcium batteries. 20 year sealed Lead-Calcium or wet Nickel-Cadmium batteries also available. 90 min. standard discharge time at full load under normal operating temperature. Low Voltage Disconnect protection included. No special ventilation required. SELF-DIAGNOSTICS Automatic self tests consist of a 5-minute monthly and 90-minute annual function. The front-mounted control panel includes 5 LED indicators, a 2-line 20-character LCD display, a keypad to control and monitor the internal operation of the system. This allows the operator to easily “watch” system functions as they occur and check on virtually any aspect of the system’s operation. Standard RS232 diagnostic interface. ELECTRICAL OUTPUT Voltage 120 or 277VAC 1-phase 2-wire. Contact factory for all other voltages. Static Voltage Load current change +/-2%, battery discharge +/-12.5% Dynamic Voltage +/-2% for +/-25% load step change +/-3% for a 50% load step change, recovery within 3 cycles Harmonic Distortion <3% THD for linear load High/Low Battery Charger Voltage, High/Low AC Input Voltage, Near Low Battery, Low Battery, Load Reduction Fault, Output Overload, High Ambient Temperature, Inverter Fault, Output Fault, Optional Output Circuit Breaker Trip Output Frequency 60Hz +/- 0.05Hz during emergency mode OPTIONAL FEATURES Load Power Factor 0.5 lag to 0.5 lead Inverter Overload 115% for 10 minutes, 150% for 16 line cycles Protection Optional Distribution Circuit Breaker Crest Factor 2.8 ALARMS Output Circuit Breakers, Output Trip Alarms, 20 Years Sealed Batteries, 12 Hours Fast Recharge, Internal/External Maintenance Bypass Switch, Remote Meter Panel, Remote Summary Alarm Panel, Summary Alarm Dry Form C Contact, Inverter on Dry Contacts, Fax/Modem, Bypass Relays, Auto Dialer, Seismic Mounting. FACTORY START-UP Includes one additional year of warranty. See warranty conditions. WARRANTY ENVIRONMENTAL CONDITIONS Storage/Transport • -4ºF to 158ºF (-20ºC to 70ºC) without batteries • 0ºF to 104ºF (-18ºC to 40ºC) with batteries (max. 3 months at 104° F (40° C) Operating Temperature System operates safely from 32°F to 104°F (0°C to 40°C) but optimum operation is between 68° F and 86°F (20°C to 30°C). Battery performance can be affected by temperature Altitude <10,000 feet (above sea level) without de-rating Relative Humidity 0 to 95% non-condensing Audible Noise Audible noise 45 dBA @ 1m from surface in emergency mode (full limited warranty conditions available upon request) Limited manufacturer warranty is one-year, parts and labor, for system electronics or two-year with factory start-up program. Battery warranty is one year full plus 9 years pro-rata for a total of 10 years, under normal operating conditions. System must be put in service within 6 months from ship date in order to validate warranty. 2-Consult factory for other type batteries than the standard one. SINGLE LINE DIAGRAM Output breakers are optional Characteristics, specifications or dimensions subject to change without notice. 131 CENTRAL & INVERTER SYSTEMS CATALOG #: CENTRAL & INVERTER SYSTEMS Emerg-Power Systems FTC Single Phase Series Features • 98% efficient at full load • PWM/IGBT technology • Self-testing/Self-diagnostic • User programmable with password protection • Standard input circuit breaker • RS232 communication port • Micro-processor controlled • Automatic event and alarm log • 90 min. standard run time • Generator compatibility • Electronic and magnetic ballast compatible • Custom voltages available • Automatic event, test and alarm log • LCD display • Reduced footprint (stackable cabinets) • Maintenance free standard batteries • Forced air cooling during emergency mode only UL listed to UL924. Meets NFPA101, NFPA70, NFPA 110, OSHA, UBC, SBCCI. N.Y City approved. Electrical/Mechanical Characteristics 4 (Data provided for standard Lead Calcium batteries)1,4 POWER RATING1 KVA= KW 1.5 2.25 3 3.75 5 6 8 10 12.5 16.7 1 2 MAX. INPUT CURRENT (A) EFFIC. AT FULL LOAD % 98 98 98 98 98 98 98 98 98 98 120V 16 24 32 39 50 63 84 105 131 174 277V 7 11 14 17 22 27 36 45 57 76 HEAT LOSS IN NORMAL MODE (BTU/HR) 102 153 204 255 340 408 544 680 850 1136 BATT. VDC UPS CABINET DIMENSIONS BATT. NO. OF A BATT. W” 48 72 96 120 144 180 240 144 180 240 39 38 38 37 40 40 39 82 82 80 4 6 8 10 12 15 20 24 30 40 30 30 30 30 30 30 30 30 30 30 C onsult factory for 20 year type batteries or for wet nickel cadmium batteries. Batteries are installed in the electronics cabinet for 1.5 to 5kVA systems 3 4 H” 47 47 47 47 47 47 47 47 47 47 D” 25 25 25 25 25 25 25 25 25 25 BATTERY CABINET NO. OF DIMENSIONS2, 3 BATT CAB. W” H” D” NA NA NA NA NA 30 30 30 30 30 NA NA NA NA NA 47 47 47 47 47 NA NA NA NA NA 25 25 25 25 25 NA NA NA NA NA 1 1 2 2 2 BATT. CAB. WEIGHT LBS (EMPTY) NA NA NA NA NA 210 lbs 232 lbs 420 lbs 420 lbs 464 lbs UPS CAB. WEIGHT LBS 250 lbs 265 lbs 295 lbs 305 lbs 315 lbs 350 lbs 375 lbs 435 lbs 465 lbs 530 lbs BATT. WEIGHT LBS 296 lbs 444 lbs 592 lbs 740 lbs 888 lbs 1110 lbs 1480 lbs 1776 lbs 2220 lbs 2960 lbs TOTAL SYSTEM WEIGHT LBS 546 lbs 709 lbs 887 lbs 1045 lbs 1203 lbs 1670 lbs 2087 lbs 2631 lbs 3105 lbs 3954 lbs Battery cabinets are stackable. To be installed on the right side of the electronics cabinet Special voltages or batteries may change the size, weight or number of cabinets How to Order INPUT VOLTAGE* 120 208 240 277 * Special voltages may change the size, weight or number of cabinets BATTERY TYPE SG= Sealed Lead-Calcium NC= Wet NickelCadmium VA/W RATING 1500 2250 3000 3750 5000 6000 8000 10000 12500 16700 SYSTEM TYPE -FTC OUTPUT VOLTAGE* -120 -277 -208 -120/140 -120/277 * Special voltages may change the size, weight or number of cabinets RUN TIME* -90 INPUT BREAKER -ICB RS232 PORT -RS232 OUTPUT BREAKERS* OCBxxxx= no trip alarm* OCAxxxx= with trip alarm* * Max. 12 unsupervised single pole positions or 8 with trip alarm. For more output breakers please consult factory. See page 181 for output breakers option details. * Other run times available Example: 277SG6000-FTC-277-90-ICB-RS232-OCB0420-DCS-20Y 132 OPTIONS* -20Y= 20 yr sealed batteries -12HR= 12 hr fast recharge -MBYP= internal bypass switch -EMBP= external bypass switch** -RMP= remote metering panel -RSAP= remote summary alarm panel -DCS= dry summary alarm contacts -INVON= inverter on dry contacts -NOFF= normally OFF output*** -MOD= external modem -FAX= fax modem -BPR= bypass relays -DIAL= autodialer -SEIS= seismic mounting -ZONEM= zone monitoring -BATM= battery cycle warranty monitor * See page 137 for options description ** External bypass switch is not compatible with integrated output circuit breakers. Input/output voltage has to be the same. *** Normally off loads cannot exceed 20% of total KVA rating with any combination of H.I.D. loads TYPE: CENTRAL & INVERTER SYSTEMS CATALOG #: NOTES: Uninterruptible Emergency Lighting Inverter System 1.5KVA –16.7KVA System Specifications GENERAL Design Stand-by. PWM inverter type utilizing IGBT technology with 2ms transfer time Control • Microprocessor controlled , 2 x 20-character display with touch pad controls & functions • 5 LED indicators & alarm with ring-back feature Metering Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Temperature, Inverter Wattage Communications RS-232 port (DB9) CABINETS Modular design, freestanding NEMA Type 1 steel cabinets powder coated for corrosion and scratch resistance. Front access design through hinged lockable doors requires only 39” front clearance and 12” top clearance. Cabinets are stackable if required to further reduce the footprint. Top and left side conduit entry with knockouts. INVERTER Using IGBT/PWM technology the inverter converts the DC voltage supplied by the batteries to AC voltage of a precise stabilized amplitude and frequency, suitable for most sophisticated electrical equipment. True sinusoidal output waveform with very low distortion (less than 3% for linear loads). Overload capability of up to 150% for 12 line cycles. ELECTRICAL INPUT Voltage 120 or 277VAC 1-phase 2-wire +10% - 15%. Contact factory for all other voltages Input Power Walk-In Limiting inrush current to less than 125%, 10 times for 1 line cycle Input Frequency 60Hz, +/-3%, 50Hz available upon request Protection Input Circuit Breaker Harmonic Distortion <10% Power Factor 0.5 lag/lead CHARGER Fully automatic, temperature compensated, microprocessor controlled charger recharges fully discharged batteries in maximum 24 hours at nominal AC input voltage. AC input current limiting and over-voltage protection included. BATTERY System is provided standard with 10 year, maintenance free, sealed valve regulated, front terminals Lead Calcium batteries. 20 year sealed Lead Calcium or wet Nickel Cadmium batteries also available. 90 min. standard discharge time at full load under normal operating temperature. Low Voltage Disconnect protection included. No special ventilation required. SELF-DIAGNOSTICS Automatic self tests consist of a 5-minute monthly and 90-minute annual function. The front-mounted control panel includes 5 LED indicators, a 2-line 20-character LCD display, and a keypad to control and monitor the internal operation of the system. This control panel allows the operator to easily “watch” system functions as they occur and check on virtually any aspect of the system’s operation. Standard RS232 diagnostic interface. ELECTRICAL OUTPUT Voltage 120 or 277VAC 1-phase 2-wire. Contact factory for all other voltages. Static Voltage Load current change +/-2%, battery discharge +/-12.5% Dynamic Voltage +/-2% for +/-25% load step change +/-3% for a 50% load step change, recovery within 3 cycles Harmonic Distortion <3% THD for linear load High/Low Battery Charger Voltage, High/Low AC Input Voltage, Near Low Battery, Low Battery, Load Reduction Fault, Output Overload, High Ambient Temperature, Inverter Fault, Output Fault, Optional Output Circuit Breaker Trip Output Frequency 60Hz +/- 0.05Hz during emergency mode OPTIONAL FEATURES Load Power Factor 0.5 lag to 0.5 lead Inverter Overload 115% for 10 minutes, 125% for 5 minutes, 150% for 12 cycles Protection Optional Distribution Circuit Breakers Output Circuit Breakers, Output Trip Alarms, 20 Years Sealed Batteries, 12 Hours Fast Recharge, Internal/External Maintenance Bypass Switch, Remote Meter Panel, Remote Summary Alarm Panel, Summary Alarm Dry Form C Contact, Inverter on Dry Contacts, Normally OFF output, Fax/Modem, Bypass Relays, Auto Dialer, Seismic Mounting. Crest Factor 2.8 FACTORY START-UP ALARMS Includes one additional year of warranty. See warranty conditions. ENVIRONMENTAL CONDITIONS Storage/Transport • -4ºF to 158ºF (-20ºC to 70ºC) without batteries • 0ºF to 104ºF (-18ºC to 40ºC) with batteries (max. 3 months at 104° F (40° C) Operating Temperature System operates safely from 32°F to 104°F (0°C to 40°C) but optimum operation is between 68° F and 86°F (20°C to 30°C). Battery performance can be affected by temperature Altitude <10,000 feet (above sea level) without de-rating Relative Humidity 0 to 95% non-condensing Audible Noise Audible noise 45 dBA @ 1m from surface in emergency mode WARRANTY (full limited warranty conditions available upon request) Limited manufacturer warranty is one-year, parts and labor, for system electronics or two-year with factory start-up program. Battery warranty is one year full plus 9 years pro-rata for a total of 10 years, under normal operating conditions. System must be put in service within 6 months from ship date in order to validate warranty. 2-Consult factory for other type batteries than the standard one. SINGLE LINE DIAGRAM Normally On Output Circuit AUTOMATIC TRANSFER MODULE AC TO DC BATTERY DC TO AC INPUT BREAKER MICROPROCESSOR CONTROLLED PWM BI-DIRECTIONAL INVERTER/BATT. CHARGER Output breakers are optional 133 OUTPUT BREAKER OUTPUT TRANSFORMER NORMAL EMERGENCY NORMALLY ON OUTPUT CIRCUIT CENTRAL & INVERTER SYSTEMS Emerg-Power Systems 3FTC Three Phase Series Features • 90 min. standard run time • Generator compatibility • Available in Y or ∆ input configuration • Custom voltages available • Automatic event, test and alarm log • LCD display • Reduced footprint • Maintenance free standard batteries • Forced air cooling during emergency only • 98% efficient at full load • PWM/IGBT technology • Self-testing/Self-diagnostic • User programmable with password protection • Standard input circuit breaker • Standard internal bypass switch • RS232 communication port • Micro-processor controlled • Automatic event and alarm log UL listed to UL924. Meets NFPA101, NFPA70, NFPA 110, OSHA, UBC, SBCCI. N.Y City approved. Electrical/Mechanical Characteristics4 (Data provided for standard Lead Calcium batteries)1,4 POWER RATING1 KVA= KW 4.8 6 8 10 12.5 16.7 24 33 40 50 1 2 MAX. INPUT CURRENT (A) EFFIC. AT FULL LOAD % 98 98 98 98 98 98 98 98 98 98 120V/ 208V 17 21 28 35 43 58 84 115 139 174 277V/ 480V 7 9 12 15 19 25 36 50 60 75 HEAT LOSS IN NORMAL MODE (BTU/HR) 326 408 544 680 850 1136 1632 2244 2720 3400 BATT. VDC UPS CABINET DIMENSIONS BATT. NO. OF A BATT. W” 144 180 240 144 180 240 240 240 240 240 39 39 39 81 81 81 117 160 194 243 12 15 20 24 30 40 60 40 100 60 C onsult factory for 20 year type batteries or for wet Nickel-Cadmium batteries. KVA=KW 30 30 30 30 30 30 48 48 48 48 3 4 H” 47 47 47 47 47 47 72 72 72 72 D” 25 25 25 25 25 25 31 31 31 31 BATTERY CABINET NO. OF DIMENSIONS3 BATT CAB. W” H” D” 30 30 30 30 30 30 48 48 48 48 47 47 47 47 47 47 72 72 72 72 25 25 25 25 25 25 31 31 31 31 1 1 1 2 2 2 1 2 2 2 BATT. CAB. WEIGHT LBS (EMPTY) NA NA NA NA NA 210 lbs 232 lbs 420 lbs 420 lbs 464 lbs UPS CAB. WEIGHT LBS 535 535 535 639 639 639 1250 1250 1450 1450 BATT. WEIGHT LBS 888 1110 1480 1776 2220 2960 4440 6080 7400 9120 TOTAL SYSTEM WEIGHT LBS 1633 1855 2247 2835 3279 4063 6390 8630 10150 11980 Battery cabinets up to 16.7KVA are stackable. To be installed on the right side of the electronics cabinet Special voltages or batteries may change the size, weight or number of cabinets How to Order INPUT VOLTAGE* 120/208 277/480 BATTERY TYPE SG= Sealed Lead-Calcium NC= Wet Ni-Cd VA/W RATING 4800 6000 8000 10000 12500 16700 24000 33000 40000 50000 SYSTEM TYPE -3FTC OUTPUT VOLTAGE* 120/208 277/480 RUN TIME* 90 INPUT BREAKER RS232 PORT ICB RS232 INTERNAL BYPASS SWITCH MBYP OUTPUT BREAKERS* OCBxxxx= no trip alarm* OCAxxxx= with trip alarm* OPTIONS* -20Y= 20 yr sealed batteries -12HR= 12 hr fast recharge -NOFF= normally off output 1PH** -EMBP= external bypass switch*** -RMP= remote metering panel -RSAP= remote summary alarm panel -DCS= dry summary alarm contacts -INVON= inverter on dry contacts -NOFF3= normally OFF output 3PH** -MOD= external modem -FAX= fax modem -BPR= bypass relays -DIAL= autodialer -SEIS= seismic mounting -ZONEM= zone monitoring -BATM= battery cycle warranty monitor 4 Max. * Special voltages may change the size, weight or number of cabinets * Special voltages may change the size, weight or number of cabinets 12 unsupervised single pole positions or 8 with trip alarm, up to 16.7kVA systems. 24 unsupervised or 16 with trip alarm for systems 24kVA to 50kVA. For more output breakers please consult factory. See page 137 for output breakers option details. * Other run times available Example: 277SG6000-FTC-277-90-ICB-RS232-OCB0420-DCS-20Y 134 * See page 137 for options description ** External bypass switch is not compatible with integrated output circuit breakers. Input/output voltage has to be the same. *** Normally off loads cannot exceed 20% of total KVA rating with any combination of H.I.D. loads TYPE: CENTRAL & INVERTER SYSTEMS CATALOG #: NOTES: Uninterruptible Emergency Lighting Inverter System 4.8KVA – 50KVA System Specifications GENERAL Design Stand-by. PWM inverter type utilizing IGBT technology with 2ms transfer time Control • Microprocessor controlled , 2 x 20-character display with touch pad controls & functions • 5 LED indicators & alarm with ring-back feature Metering Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Temperature, Inverter Wattage Communications RS-232 port (DB9) CABINETS Modular design, freestanding NEMA Type 1 steel cabinets powder coated for corrosion and scratch resistance. Front access design through hinged lockable doors requires only 39” front clearance and 12” top clearance. Cabinets are stackable up to 16.7kVA, if required to further reduce the footprint. Top and left side conduit entry with knockouts up to 16.7kVA. Left side only for 24kVA and up. INVERTER Using IGBT/PWM technology the inverter converts the DC voltage supplied by the batteries to AC voltage of a precise stabilized amplitude and frequency, suitable for most sophisticated electrical equipment. True sinusoidal output waveform with very low distortion (less than 3% for linear loads). Overload capability of up to 150% for 12 line cycles ELECTRICAL INPUT Voltage 120/208 or 277/480 3 phase 4-wire +10% - 15%. Contact factory for all other voltages Input Power Walk-In Limiting inrush current to less than 125%, 10 times for 1 line cycle Input Frequency 60Hz, +/-3%, 50Hz available upon request Protection Input Circuit Breaker Harmonic Distortion <10% Power Factor 0.5 lag/lead CHARGER Fully automatic, temperature compensated, microprocessor controlled charger recharges fully discharged batteries in maximum 24 hours at nominal AC input voltage. AC input current limiting and over-voltage protection included. BATTERY System is provided standard with 10 year, maintenance free, sealed valve regulated, front terminals lead calcium batteries. 20 year sealed Lead Calcium or wet Nickel Cadmium batteries also available. 90 min. standard discharge time at full load under normal operating temperature. Low Voltage Disconnect protection included. No special ventilation or filters required SUPERVISION Automatic self tests consist of a 5-minute monthly and 90-minute annual function. The front-mounted control panel includes 5 LED indicators, a 2-line 20-character LCD display, a keypad to control and monitor the internal operation of the system. This allows the operator to easily “watch” system functions as they occur and check on virtually any aspect of the system’s operation. Standard RS232 diagnostic interface. ELECTRICAL OUTPUT Voltage 120/208 or 277/480VAC 3-phase 4-wire Contact factory for all other voltages. Static Voltage Load current change +/-4%, battery discharge +/-4% Dynamic Voltage +/-3% for +/-25% load step change +/-6% load step change, recovery within 3 cycles Harmonic Distortion <3% THD for linear load Output Frequency 60Hz +/- 0.05Hz during emergency mode Load Power Factor 0.5 lag to 0.5 lead Inverter Overload 115% for 5 minutes, 125% for 10 minutes, 280% for line cycles Protection Optional Distribution Circuit Breakers Crest Factor 2.8 ALARMS High/Low Battery Charger Voltage, High/Low AC Input Voltage, Near Low Battery, Low Battery, Load Reduction Fault, Output Overload, High Ambient Temperature, Inverter Fault, Output Fault, Optional Output Circuit Breaker Trip. OPTIONAL FEATURES Output Circuit Breakers, Output Trip Alarms, 20 Years Sealed Batteries, 12 Hours Fast Recharge, External Maintenance Bypass Switch, Remote Meter Panel, Remote Summary Alarm Panel, Summary Alarm Dry Form C Contact, Inverter on Dry Contacts, Normally OFF output, Fax/Modem, Bypass Relays, Auto Dialer, Seismic Mounting. FACTORY START-UP Includes one additional year of warranty. See warranty conditions. WARRANTY ENVIRONMENTAL CONDITIONS Storage/Transport -4ºF to 158ºF (-20ºC to 70ºC) without batteries (max. 3 months at 104° F (40° C) -0ºF to 104ºF (-18ºC to 40ºC) with batteries Operating Temperature System operates safely from 32°F to 104°F (0°C to 40°C) but optimum operation is between 68° F and 86°F (20°C to 30°C). Battery performance can be affected by temperature Altitude <10,000 feet (above sea level) without de-rating Relative Humidity 0 to 95% non-condensing Audible Noise 45 dBA @ 1m from surface in emergency mode (full limited warranty conditions available upon request) Limited manufacturer warranty is one-year, parts and labor, for system electronics or two-year with factory start-up program. Battery warranty is one year full plus 9 years pro-rata for a total of 10 years, under normal operating conditions. System must be put in service within 6 months from ship date in order to validate warranty. 2- Consult factory for other type batteries than the standard one. SINGLE LINE DIAGRAM Normally On Output Circuit Output breakers are optional Characteristics, specifications or dimensions subject to change without notice. 135 NORMAL EMERGENCY CENTRAL & INVERTER SYSTEMS TYPE: CATALOG #: NOTES: Emerg-Power Systems FTC3R & 3FTC3R Outdoor Uninterruptible Emergency Lighting Inverter System 3KVA-8KVA Features • 98% efficient at full load • PWM/IGBT technology • Self-testing/Self-diagnostic • Standard input circuit breaker • Standard internal bypass switch • RS232 communication port • Standard seismic zone 4 brackets • Standard summary dry contacts • Automatic event and alarm log • NEMA 3R cabinet for outdoors • 90 min. standard run time • Generator compatibility • Custom voltages available • Automatic event, test and alarm log • LCD display • One size cabinet • Maintenance free standard 5 year batteries • Temperature controlled cooling fans Electrical/Mechanical Characteristics3, 4 UL listed to UL924. Meets NFPA101, NFPA70, NFPA 110, OSHA, UBC, SBCCI. N.Y City approved. POWER RATING KVA= KW EFFIC. AT FULL LOAD % HEAT LOSS (BTU) BATT. VDC UPS CABINET DIMENSIONS NO. OF BATT.2 BATT. A W”1 H” UPS CAB. WEIGHT LBS BATT. CAB. WEIGHT LBS TOTAL SYSTEM WEIGHT LBS D” 3 (1PH) 98 255 120 37 10 48 76 30 535 lbs 888 lbs 1633 lbs 4 (1PH) 98 340 144 40 12 48 76 30 535 lbs 1110 lbs 1855 lbs 5 (1PH) 98 408 180 40 15 48 76 30 535 lbs 1480 lbs 2247 lbs 6.5 (1PH) 98 544 240 39 20 48 76 30 639 lbs 1776 lbs 2835 lbs 8 (1PH) 98 680 144 82 24 48 76 30 639 lbs 2220 lbs 3279 lbs 4 ( 3PH) 98 326 144 39 12 48 76 30 639 lbs 2960 lbs 4063 lbs 5 ( 3PH) 98 408 180 39 15 48 76 30 1250 lbs 4440 lbs 6390 lbs 6.5 (3PH) 98 544 240 39 20 48 76 30 1250 lbs 6080 lbs 8630 lbs 8 (3PH) 98 680 144 81 24 48 76 30 1450 lbs 7400 lbs 10150 lbs F actory installed floor mount brackets; add 2.5” to each side (total 53”) 2 Standard batteries are 5 year life expectancy. Batteries are installed in the same cabinet with electronics U L rated for 90 min. run time for temperatures: 50ºF to 104ºF (10ºC to 40ºC) or -4ºF to 104ºF (-20ºC to 40ºC) with optional heater 4 NEMA type 3R, freestanding, two-door powder coat cold rolled steel cabinet standard. Stainless steel enclosure is optional 1 3 How to Order INPUT VOLTAGE* 120, 1PH 208, 1PH 240, 1PH 277, 1PH 120/208, 3PH 277/480, 3PH * 1PH are input voltages available for 1 phase systems. 3PH are input voltages available for 3phase systems. BATTERY TYPE SG= Sealed Lead-Calcium VA/W RATING* 3000 4000 5000 6500 8000 * Not available in 3 phase version SYSTEM TYPE FTC3R= single phase 3FTC3R= 3 phase OUTPUT VOLTAGE* RUN TIME* INPUT BREAKER 120 208 277 120/208 277/480 90 ICB * 1PH are input voltages available for 1 phase systems. 3PH are input voltages available for 3phase systems. RS232 PORT RS232 INTERNAL BYPASS SWITCH MBYB OUTPUT BREAKERS* OCBxxxx= no trip alarm* OCAxxxx= with trip alarm* * Max. 14 unsupervised single pole positions or 8 with trip alarm. For more output breakers please consult factory. See page 137 for output breakers option details. * Other run times available Example: 120SG4000-FTC3R-120-90-ICB-RS232-MBYB-OCB0420-10Y 136 OPTIONS* 10Y= 10 yr sealed batteries 12HR= 12 hr fast recharge NOFF= normally off output** EMBP= external bypass switch*** RMP= remote metering panel RSAP= remote summary alarm panel HTR= heater INVON= inverter on dry contacts MOD= external modem FAX= fax modem BPR= bypass relays SS= stainless steel enclosure * See page 137 for options description Summary alarm dry contacts and seismic brackets are standard. ** Normally off loads cannot exceed 20% of total KVA rating with any combination of H.I.D. loads *** Not available in 3 phase version. Option Details INTEGRATED OUTPUT CIRCUIT BREAKERS: -OCB 12 20 Trip Alarm Number of Circuit Breakers OCB - No Breaker Trip Alarm Combination of 1 pole, 2 pole and 3 pole breakers available. Breaker Rating (Amps) OCA - With Breaker Trip Alarm * For max. number of circuit breakers available please consult factory * Various ratings available Number of poles Breaker Voltage Operation Mode Blank - 1 pole Blank- matches system output voltage Blank: Normally-On -2P - 2 poles -120VAC -3P - 3 poles -208VAC -NOFF: Normally-Off -240VAC -277VAC -480VAC Distribution circuit breakers are for output load protection. Protection for the normally on and/or for the normally off loads. All circuit breakers are rated for 10,000 AIC. If ordered, an audible and visual alarm activates when an output distribution circuit breaker is open or has tripped. (-20YR) 20 YEAR SEALED LEAD CALCIUM BATTERIES Maintenance free battery requires no addition of water over the life of the battery. The battery cells are housed in protective, modular steel trays. Life expectancy is designed for 20-years at 77ºF (25ºC). (-NOFF) NORMALLY OFF OUTPUT This output circuit is dedicated for the “emergency only” equipment. Emergency only equipment operates during power outages and when the system is on battery back up. This option leaves the normally off load circuits off during normal utility power conditions. A 1-pole circuit breaker is provided. For 3 phase systems, 3 pole normally off circuits are available as well. (-12HR) 12 HOUR FAST RECHARGE Battery charger upgrade option which decreases the time required to return a fully discharged battery to the fully charged state. The normal 24 hour recharge cycle is reduced to a 12 hour period. (-MOD) EXTERNAL MODEM External modem device is designed to boost the signal level of the RS-232 diagnostic interface to remote monitoring locations located more than 100 feet away from the system. (-MBYP) INTERNAL MAINTENANCE BYPASS SWITCH Internally mounted device permits maintenance personnel to easily bypass the protected equipment directly to the AC utility power. The manual make before break switch isolates the system to perform routine maintenance or servicing without interruption of utility power to the connected load. (-FAX) INTERNAL FAX MODEM The internal fax modem enables the system to send a fax automatically to several pre-programmed numbers when one of the following conditions occurs: utility failure, output failure or any alarm. The Fax Modem option requires a user supplied dedicated phone line. (-EMBP) EXTERNAL MAINTENANCE BYPASS SWITCH The external maintenance bypass switch is mounted in a 20”H x 16”W x 9”D NEMA 1 separate enclosure, used to completely isolate the inverter system from the connected load and AC utility input. This option allows the system to be safely powered down for maintenance or service. The option may not be used on systems with more than one single pole output circuit breaker which must be sized for the total system output current. (-BPR) BYPASS RELAYS Internal bypass relays will allow overriding circuits that can be switched on/off, so in case of a power failure the emergency circuits will be supplied from the inverter system whatever the position of the switching device. Please consult factory for more details. (-RMP) REMOTE METER PANEL The panel allows monitoring of parameters and control from remote locations up to 150 feet away from the inverter system. Also, the remote panel provides a complete touch pad interface allowing the user to monitor, control and program the inverter system. (-DIAL) AUTO DIALER The Auto Dialer modem option automatically dials up to four userprogrammable phone numbers in the event of any system alarm condition. The option is designed to deliver a predetermined digital or audible message when activated. The Auto Dialer option requires a user supplied dedicated digital or analog phone line. (-RSAP) REMOTE SUMMARY ALARM PANEL Wall mountable box provides visual and audible alarms with silent switch. The panel consists of LED indicators and built-in audible alarm and may be located up to 1,000 feet away from the inverter system. (-SEIS) SEISMIC MOUNTING KIT The seismic mounting kit option is designed to prevent system movement during seismic events. Heavy-duty brackets are provided to secure system cabinetry to floor surfaces. Meets Zone 4 requirements. (-DCS) SUMMARY ALARM DRY CONTACTS Form C dry contacts for remote monitoring purposes. Rated at 5 amps max. (250VAC/30VDC), the contacts will change state when any of the following alarms: are tripped High/Low Battery Charger Voltage, High/Low AC Input Voltage, Near Low Battery Voltage, Low Battery Voltage, Load Reduction Fault, High Ambient Temperature, Inverter Fault, Output Fault, Output Overload or Optional circuit breaker. (-ZONEM) ZONE MONITORING Allows voltage monitoring of different circuits than the standard AC utility input. When the voltage of one of these circuits drops, the inverter system will go into battery back-up operation mode. Number and voltage of the monitored circuits to be specified. (-RS232) DIAGNOSTIC INTERFACE A microprocessor-based data acquisition system designed to monitor all the system parameters remotely. Monitors alarm log, event log and automatic test log. User can command the system to perform a battery test and review all system parameters. Access is through a DB9 connector and transmits at 9600 baud. (-INVON) INVERTER ON DRY CONTACTS Form C dry contacts that will change state when the system transfers to battery operation (-VTD) VARIABLE TIME DELAY (FOR NORMALLY OFF CIRCUITS) After a return of AC utility power, delays retransfer of the inverter for up to 15 min. and continues to supply emergency power to the normally off circuits. (-BATM) BATTERY CYCLE WARRANTY MONITOR Device providing battery monitoring at string level or cell level. Please consult factory for more details. 137 CENTRAL & INVERTER SYSTEMS EMERG-POWER SYSTEMS CENTRAL & INVERTER SYSTEMS EMERG-POWER SYSTEMS Control Panel & Display Meter Functions Program Functions • AC Voltage Input • AC Voltage Output • AC Current output • Battery Voltage • Battery Current • VA Output • Inverter Watts • Ambient Temperature • System Days (cumulative) • Inverter Minutes (cumulative) • Set Date • Set Time • Set Monthly Test Date and Time • Set Annual Test Date and Time • Set Load Fault Reduction Setting • Set Low Battery Alarm • Set Near Low Battery Alarm • Set Low AC Voltage Alarm • Set High AC Alarm • Set Ambient Temperature Alarm Alarms Control Functions • High Battery Charger Voltage • Low Battery Charger Voltage • High AC Input Voltage • Low AC Input Voltage • Near Low Battery Voltage • Low Battery Voltage • Load Reduction Fault • High Ambient Temperature • Inverter Fault • Output Fault • Output Overload •Test and Event Logs (75 logs stored) Logs record the following data: Date, Time, Duration, Output Voltage, Output Current, Ambient Temperature and Alarms Present. •A larm Logs (50 logs stored) Logs record the following data: Date,Time and Alarm type • Buzzer On/Off (toggle) •5 LED Indicators and Alarms with Ringback Feature System Testing Manual tests of system may be performed at any time using the control panel test key. Automatic self-diagnostic tests consist of a 5-minute monthly and 90-minute annual function (the user can program the date and time of day the test is to take place). The microprocessor automatically records the last 75 test events in its own separate test result log. 138 Central Systems Request Data 1) Input voltage Single phase (2 wire + ground) 120VAC 208VAC 240VAC Three phase (4 wire + ground, Y) 120/208VAC 277/480VAC 347/600VAC Three phase (3 wire + ground, Δ) 208VAC 480VAC 600VAC Single phase (2 wire + ground) 120VAC 208VAC 277VAC Single phase (3 wire + ground) 120/240VAC 120/277VAC Three phase (4 wire + ground, Y) 120/208VAC 277/480VAC 277VAC 2) Output voltage 3) System capacity KVA rating: System Series Type: a) Please consider power consumption and maximum current of the complete lamp fixture not just the lamp wattage (ie: ballasts consumption) b) Please consider loads power factor c) Even if the systems can run with 100% load, it is recommended as standard practice to use a system with a capacity at least 10% over maximum connected load 4) Type of loads Incandescent Fluorescent H.I.D (metal halide, high pressure sodium, etc.) Other 5) Mode of operation Normally ON (24/7) Normally OFF (emergency only) Switched loads ON/OFF Please consider internal bypass relays or external override relays for switched On/Off loads. Each switched output circuit will require a bypass relay. Maximum 20 A per circuit. LED 6) Integrated output circuit breakers # of CB Amps Voltage # of poles NON NOFF Trip alarm # of CB Amps Voltage # of poles NON NOFF Trip alarm 7) Type of Batteries (check availability for each type system) 10 yr sealed lead calcium 20 yr sealed lead calcium wet nickel cadmium 8) Options (refer to available options for each system type) (12HR-) 12 Hour Fast Recharge RS232- diagnostic interface ZONEM- zone monitoring MBYP- internal bypass switch NOFF – normally OFF output VTD- variable time delaye EMBP- external bypass switch MOD- external modem BATM – battery cycle warranty monitor RMP- remote meteing panel FAX- fax modem RSAP- remote summary alarm panel BPR- bypass relays How many ____ DCS- dry summary alarm contacts DIAL- auto-dialer INVON- inverter on dry contacts SEIS- seismic mounting kit 139 CENTRAL & INVERTER SYSTEMS EMERG-POWER SYSTEMS Table of Contents Wire Guards 142-143 Accessories 144-145 Lamp Data 146-147 Wire Size Guard 141 148 National Electrical Code 149-151 Life Safety Code 152-154 Limited Warranty 155 Product Index 156 ACCESSORIES & GENERAL INFO. ACCESSORIES & GENERAL INFORMATION ACCESSORIES & GENERAL INFO Wire Guards Catalog Number WG1-E Catalog Number WG5-E Application • J S Series (small cabinet) •P S Series (surface or semi-recessed) •E F24 or EF24R remote lighting fixture •P remier™ Battery Unit •P remier™ Exit Sign (wall mount) Application 14” 12” 13-3/4” 16” •X 10 (end or ceiling mounted) AC and AC/ DC or Self-Powered exit with no mounted heads •E CL & ECLXN Series LED (end or ceiling mounted) AC and AC/DC or Self-Powered •P receptor™ Series LED (AC and AC/DC or Self-Powered) (end or ceiling mounted) •P restige™ DX Series LED and Thin Die-Cast Series (end or ceiling mount) •P remier™ Exit Sign (end or ceiling mount) Catalog Number WG6-E Catalog Number WG2-E Application Application • J S Series (large cabinet) •A ll A cabinets •P remier™ Combo Series (wall mount) •S ingle EF22 head •X 10 mini systems (wall mounted) with front mounted EF9 head(s) (wall mounted) •K S Series with front mounted heads Catalog Number WG7-E Catalog Number WG3-E Application Application • IL Series •A ll B and C cabinets •E F22D heads • RS Series with cylinder •E F32 heads Catalog Number WG8-E Catalog Number WG4-E Application Application •A ll D cabinets •K S Series (not for front mounted heads) • Single remote EF9, EF11, • EF16, EF18, EF28, or •E F32 lighting head 142 ACCESSORIES & GENERAL INFO. Wire Guards Catalog Number WG13-E Catalog Number WG9-E Application Application •D ouble or triple remote EF9, EF11, EF18, EF28 or EF32 lighting heads •R S Series with EF9 or EF18 heads •E CS-2 Series •P RO-2N Series •P receptor™ Series Self-Powered (wall mount) Catalog Number WG14-E Catalog Number WG10-E Application Exit Signs (Ceiling Mount) Application 20” • J S Series with front mounted heads 12” •P restige™ Floor Proximity Series (6” & 8”); •P receptor™ Die-Cast Series; •P restige™ Thin Die-Cast Series; • X10 LED Series, • Premier™ Exit Series; 12” 15” 23” 13-3/4” 13-3/4” Catalog Number WG15-E Catalog Number WG11-E Application Exit Signs (Ceiling Mount) Application •F ully recessed PS Series •G S Series •E F15, EF20, EF21R, EF35 lighting fixtures •F ully recessed Preceptor™ Series •P restige™ Thin Die Cast Exit Sign (wall mounted) •P restige™ Floor Proximity Series (6” & 8”); •P receptor™ Die-Cast Series; •P restige™ Thin Die-Cast Series; • X10 LED Series, • Premier™ Exit Series; Catalog Number WG12-E Application 13-1/2” •X 10 Series LED (AC and AC/DC or Self-Powered) (wall mount) 4-1/2” •E CL & ECLXN Series LED AC and AC/DC or Self-Powered (wall mount) 10-1/4” •P receptor™ Series LED (AC and AC/DC or Self-Powered) (wall mount) •P restige™ DX Series LED AC and AC/DC or Self-Powered (wall mount) •R emote EF13, EF14, or EF17 fixtures 9-5/8” 9-5/8” 11-7/8” 11-7/8” 9” 15” 143 8-3/8” 8-3/8” 15-5/16” 15-5/16” 10-1/4” 10-1/4” MP3 Mounting Platform Catalog Number VRS or VRS-4X NEMA-4X Application •M E Series with top mounted heads •P S Series all mountings •X 10 LED, (wall mounted) AC and AC/DC or Self-Powered exit with no mounted heads •E CL Series LED (wall mounted) AC and AC/DC or Self-Powered •P receptor™ Series LED, (wall mounted) AC and AC/DC Constructed of 18 gauge. steel, the MP3 mounting platform will accommodate all our unit equipment in our ‘B’ cabinet. 6” 15-1/8” How To Order MP3-EG MP3-GY 9-1/8” Mounting platform Mounting platform, gray 3/16” DIAM. 8” 14-1⁄2” 5-1/4” 7/16” DIAM. 10-1⁄4” 16-3⁄8” Catalog Number VRS-BB or VRSBB-4X NEMA-4X Application • J S Series (small cabinet) top or front mounted heads •E CC & ECM Series (small cabinet) 5-3⁄4” MP6, MP12, MP24 Mounting Platform Constructed of 18 gauge. steel, the MP6, MP12, and MP24 mounting platform will accommodate our unit equipment in our ‘C’, ‘D’, and ‘E’ cabinets respectively. How To Order MP6-EG MP12 MP24 Mounting platform (off white) Mounting platform (off white) Mounting platform (off white) Optional colors available, contact your sales representative Part # A MP6 17” MP12 27.5” MP24 27.5” B C D 7.75” 12.25” 16” 7.75” 12.25” 16” 11.63” 12.25” 16” D 5/16” DIAM. 5/8” DIAM. C Remote Test Switch Make testing your ceiling mounted equipment easier with the remote test switch. Compatible with 120 or 277 VAC circuits, the remote test switch will interrupt the line voltage to your equipment by means of a momentary push button switch. AC on/Charge status indicator lamp assures that power is going to your emergency lighting. How To Order B A B1 and B12 Mounting Brackets 2-3/4” Constructed of 16 gauge. steel, the B1 and B2 mounting bracket will accommodate our unit equipment in our ‘A’ and ‘B’ cabinets respectively. Metal faceplate, chrome RTS Plastic Faceplate plastic, off white RTS-1 4-1/2” How To Order B1 B2 Mounting bracket (off white) Mounting bracket (off white) 3-5⁄16” ACCESSORIES & GENERAL INFO Accessories Part # B1 B2 A 10” 14 1/4” B 7” 11 3/4” C 7 1/2” 12 5/8” A B C 2-1/4” 11-5/16” 21-5/16” ø1/4” (4 PLCS) 144 1/2” 230.1238-E & 230.1239-E Off-White - 230.1238-E Black - 230.1239-E 430.0765-E & 430.0766-E Off-White Single - 430.0765-E Off-White Double - 430.0766-E •S ingle, Double or Triple Round •T hermoplastic Construction •O ff-white or black finish only •M ount direct to 4” octagonal box Dimensions: 5” diameter - slotted mounting holes 3 to 3 9/16” mounting center Standard: EF18, EF18D; and EF9, EF9D •S ingle or double round •A luminum construction •M atte white baked enamel finish •B lack finish optional •M ount direct to 4” octagonal box Dimensions: 5 1/4” diameter 3 7/16” mounting center Standard: EF32 and EF32D 450.0129-E, 450.0397-E & 450.0398-E 450.0129-E - No Square Hole 450.0397-E - No Square Hole 450.0398-E - No Square Hole 450.0194-E - 1/2” 450.1153-E - 1/2” 450.1155-E - 1/2” Square Hole Square Hole Square Hole 330.7583-E & 330.7584-E Off-White Single 330.7583-E •S ingle, double or triple rectangular •S ingle, triple or 4-gang steel construction •C hrome plated finish only •M ount direct to standard outlet box Dimensions: single - 2 3/4” X 4 1/2” (for 1 fixture) 3-gang - 6 7/16” X 4 1/2” (for 2 fixtures) 4-gang - 8 3/8” X 4 1/2” (for 3 fixtures) Standard: EF28, EF28D; EF18T and EF28T •S ingle or double round •D ie-cast aluminum construction •G asketed weatherproof •O ff-white or black powder paint finish only •M ount direct to 4” octagonal box Dimensions: 4 1/8” diameter 3 9/16” mounting center Standard: EF11 and EF11D Black Single 330.7577-E Off-White Double 330.7584-E Black Double 330.7578-E Gasket - 245.0100-E 12804-E & 12805-E 12804-E •S ingle or double rectangular •D ie-cast aluminum construction •G asketed weatherproof •S ilver gray enamel finish only •M ount direct to standard outlet box Dimensions: 4 5/8” X 2 7/8” 3 1/4” mounting center Standard: Non standard mounting plate 145 12805-E ACCESSORIES & GENERAL INFO. Specify mounting plate designation as a suffix to fixture type model number. Plates ordered separately, specify plate designation and fixture type. ACCESSORIES & GENERAL INFO Lamp Data General Information select the lamp type, the voltage and wattage required and add the symbol designation to the catalog number. Not all lighting fixtures and lamp types are compatible, always check individual lighting fixture “How to Order” information. All Emergi-Lite® Lighting Fixtures are furnished complete with lamps; however, all fixtures and unit model numbers must include a lamp designation. Unless otherwise noted, the standard lamp furnished with each lighting fixture is a 9W High Intensity Incandescent lamp of the designated voltage. Example: Example A Normally Furnished Lamp: EF18 (ZD) (6V-9W Wedge Base Incandescent) PART NUMBER FIXTURES EF18 (ZD) LSM 110-2Z (6V-9W) Lighting Head Requiring different Lamp: (6V-25W Sealed Beam Lamp) EF18 (ZF) 12LSM 110-2Z (12V-9W) Change Catalog Number to: EF18 (UC) EF18 (ZN) 24LSM 110-2Z (24V-9W) When an alternate lamp is required, refer to the lamp selection charts below, PART NUMBER LAMP TYPE High Intensity Tungsten (HIT) Lamps RP-11 S-8 Double Contact Bayonet Base Bi-Pin Halogen Lamps T-2 3/4 T-2 1/4 Sealed Beam Halogen Lamps 570.0010 570.0020 570.0037 570.0038 570.0011 570.0022 570.0030 570.0031 570.0058 570.0040 570.0061 580.0012 580.0013 580.0017 580.0011 580.0022 580.0014 580.0015 580.0016 580.0027 PART NUMBER LAMP TYPE PAR 36 Sealed Beam Incandescent Lamps PAR 36 High Intensity Incandescent, Wedge Base 550.0022 550.0036 550.0037 550.0019 550.0021 550.0024 550.0025 550.0047 550.0012 550.0018 550.0030 550.0016 550.0017 550.0035 550.0026 550.0027 550.0023 550.0034 PART NUMBER LAMP TYPE T-5 570.0012 570.0026 570.0016 570.0025 570.0028 570.0029 570.0045 570.0046 VOLTAGE (V) POWER (W) AVERAGE LUMEN IA IM IB IC IE IN IF IG II IJ IK HA HB HC HD HE HF HG HH HI 6 6 6 6 12 12 12 12 24 24 24 6 6 6 6 6 12 12 12 12 9 13 18 25 9 13 18 25 9 18 25 6 8 10 12 20 8 12 14 20 126 188 300 400 126 188 276 400 75 250 400 113 163 200 240 400 163 276 300 314 10 15 24 32 10 15 22 32 6 20 32 9 13 16 19 32 13 22 24 25 CATALOG SUFFIX VOLTAGE AVERAGE LUMEN CENTER-BEAM CANDLE POWER (CBCP) XA XB XC XD XE XF XG XH XI UA UI UB UC UD UE UF UG UH 6 6 6 6 6 12 12 12 12 6 6 6 6 6 12 12 12 12 107 155 190 225 380 130 240 700 950 130 180 270 400 460 190 210 395 430 400 550 650 850 1,400 550 850 70,000 2,000 400 1,100 1,500 800 5,500 1,110 1,500 400 35,000 CATALOG SUFFIX VOLTAGE ZP ZL ZD ZF ZG ZH ZN ZO 6 6 6 12 12 12 24 24 LAMP CODE WATTS 6 8 10 12 20 8 12 37 50 8 12 18 25 30 12 18 25 30 WATTS 5.4 7.2 9 9 12 18 9 18 146 AVERAGE LUMEN 68 100 150 138 150 264 113 240 TOTAL CANDLE POWER (CP) TOTAL CANDLE POWER (CP) 5.4 8 12 11 12 21 9 19 LAMP # 135 88 1130 1134 138 94 139 1076 304 142 1638 784 785 787 786 788 774 783 789 782 LAMP # H7556 H7551 H7552 H7553 H7554 H7555 H7557 H7616 H7614 7613 4042 4014 4510 4515 4044 4414 4446 4416 LAMP # 939 927 908 915 912 921 EMS2209W EMS2218W BULB TYPE S-8 S-8 S-8 RP-11 S-8 S-8 S-8 S-8 C-2F S-8 S-8 T-2 1/4 T-2 1/4 T-2 1/4 T-2 1/4 T-2 1/4 T-2 1/4 T-2 1/4 T-2 3/4 T-2 3/4 BULB TYPE PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 PAR 36 BULB TYPE T-5 T-5 T-5 T-5 T-5 T-5 T-5 T-5 General Information PART NUMBER LAMP TYPE MR16 Halogen Lamps MR16 LED Lamps CATALOG SUFFIX VOLTAGE WATTS AVERAGE LUMEN CENTER-BEAM CANDLE POWER (CBCP) BEAM ANGLE (DEGREES) BULB TYPE 580.0072 MH 6 5.4 34 73 36 MR16 580.0074 580.0079 580.0099 580.0080 580.0064 580.0075 580.0068 580.0083 580.0076 580.0089 580.0070 580.0077 580.0094 580.0084 580.0078 580.0065 580.0066 580.0067 580.0097 580.0093 580.0104 580.0106 580.0098 580.0095 MI MJ MO MK MG MA MW MB MC MM MS MD MN ME MF MT MU MV LA LG LI LJ LL LV 6 6 12 12 12 12 12 12 12 12 24 24 24 24 24 120 120 120 6 12 12 12 24 120 6 10 10 12 20 20-A 20-H 35 50 50-H 12 20 20-A 35 50 20 35 50 4 4 5 6 4 4 40 77 86 135 270 245 417 490 785 1550 95 240 195 460 875 100 230 460 130 170 340 540 200 200 130 790 200 320 525 600 950 3300 2800 5700 280 740 890 990 3200 240 520 1100 600 440 900 1800 900 900 24 16 36 36 36 36 36 24 24 24 36 24 24 36 24 36 36 36 24 30 24 25 24 24 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 MR16 LAMP TYPE PART NUMBER EXIT Signs, Hazardous Locations Incandescent Lamps 580.0086 570.0071 570.0118 570.0136 LAMP TYPE PART NUMBER EXIT Signs, 120VAC Incandescent 570.0013 570.0024 570.0035 595.0010 CATALOG SUFFIX XX6 XX12 XX24 AC VOLTAGE 145 120 145 120 VOLTAGE 6 12 24 120 WATTS 15 20 15 7 WATTS AVERAGE LUMEN 15 25 25 25 210 220 220 215 AVERAGE LUMEN TOTAL CANDLE POWER (CP) 150 90 150 330 12 7 12 26 TOTAL CANDLE POWER (CP) BULB TYPE LAMP # 17 18 18 17 JC6V-15W2KG4 13769 24227-1 97478 LAMP # Bi-Pin G4 A19 A19 A19 BASE TYPE 15T6145 20T61/2 15T6 PL7-T4 Candelabra Screw Base Intermediate Screw Base Intermediate Screw E17 G23 Important: Lumen rating and candle power values are only for general reference. The data was obtained from the manufacturer’s catalogs, calculations or third-party laboratory measurements. Actual performance in the field may and will vary. Explosion-Proof Incandescent Lamps ITEM P/N CATALOG SUFFIX 580.0086 XX6 570.0071 570.0118 570.0136 540.0180 XX12 XX24 AC XX120 VOLTAGE 6 12 24 120 120 LUMEN RATING WATTS 120 Volt AC Exit Lamps LAMP TYPE LAMP # 15 225 JC-6V15W 25 25 25 5 378 345 215 – – – – Red LED MSA Incandescent Lamp Adapter CATALOG WATTS LAMP # Incandescent 570.0013 15 15T6145 Incandescent 570.0024 20 20T61/2 Incandescent 570.0035 15 15T6 Fluorescent 595.0010 7 PL7-T4 How to Order (example) For HIT, DCBB or Bi-Pin Halogen Lamps LAMP SYMBOL PRODUCT CODE DC lamp plus adapter for medium Edison screw base socket. This device converts any incandescent fixture into an emergency fixture. MSA HB Note: Lumen figures based on information supplied by lamp manufacturers. Lamp drawings shown are for shape comparison only, not actual size. MSA Bi-Pin MSA Double Contact MSA Wedge Base 147 BASE Candelabra Screw Base Intermediate Screw Base Intermediate Screw Base G23 ACCESSORIES & GENERAL INFO. Lamp Data ACCESSORIES & GENERAL INFO Wire Size Guard Determining Wire Size The following information is provided to assist in designing proper emergency lighting systems effectively and economically by using the smallest permissible wire size for load circuits. When remote lighting fixtures and/or exit signs are connected to emergency lighting units, circuit runs must be of sufficient size to maintain a proper operating voltage to all lamps. The National Electrical Code limits voltage to drop to a maximum of 5% of nominal. The table below gives the maximum length or wire run based on systems voltage, wire gauge and total wattage on the run. To determine the maximum length of a wire run not listed, divide the value of the load in watts into the constant listed at the bottom of each row. Example, the maximum wire run for #10 wire on a 12 volt system, with a 54 watt load, is 3397 ÷ 54 or, or 62 feet. Conversely, to determine the maximum load on a run of known length, divide the length into the constant. Example, a 36 foot run of #12 wire on a 6 volt systems can be loaded to, 534 ÷ 36, or 14 watts; on #10 wire, 23 watts. WIRING DISTANCE IN FEET (MAXIMUM VOLTAGE DROP 5%) Total watts on wire run 6 volt wire size #12 #10 12 volt wire size #8 #6 #12 #10 #8 24 volt wire size #6 #4 #12 #10 #8 #6 6 89 141 225 357 356 566 900 1431 + 1425 + + + 8 66 106 168 268 267 424 675 1073 1707 1068 1698 + + 9 59 94 150 238 237 377 600 954 1517 949 1509 + + 10 53 84 135 214 213 339 540 859 1366 854 1358 + + 12 44 70 112 178 178 283 450 715 1138 712 1132 1801 + 16 33 53 84 134 133 212 337 536 853 534 849 1350 + 18 29 47 75 119 118 188 300 477 758 474 754 1200 1909 24 22 35 56 89 89 141 225 357 569 356 566 900 1431 25 21 33 54 85 85 135 216 343 546 341 543 864 1374 27 19 31 50 79 79 125 200 318 505 316 503 800 1272 30 17 28 45 71 71 113 180 286 455 284 452 720 1145 36 14 23 37 59 59 94 150 238 379 237 377 600 954 42 12 20 32 51 50 80 128 204 325 203 323 514 818 45 11 18 30 47 47 75 120 190 303 189 301 480 763 48 11 17 28 44 44 70 112 178 284 178 283 450 715 50 10 16 27 42 42 67 108 171 273 170 271 432 687 75 7 11 18 28 28 45 72 114 182 113 181 288 458 100 5 8 13 21 21 33 54 85 136 85 135 216 343 150 — 5 9 14 14 22 36 57 91 56 90 144 229 200 — — 6 10 10 16 27 42 68 42 67 108 171 250 — — 5 8 8 13 21 34 54 34 54 86 137 300 — — — 7 7 11 18 28 45 28 45 72 114 400 — — — 5 5 8 13 21 34 21 33 54 85 500 — — — — — 6 10 17 27 17 27 43 68 Constant 534 849 1350 2148 2137 3397 5403 8590 13660 8548 13588 21613 34363 Longer Wire Runs The wiring distances give the maximum length of a battery circuit, assuming that the entire load is concentrated at the end of the circuit. If loads are uniformly spaced along the circuit path (equal watts, equal distances), the lengths in the table may be increased, based on number of fixtures on a given circuit, by means of the chart and formula below. NUMBER OF FIXTURES Multiply by Feet 2 1.33 3 1.5 4 1.6 5 1.67 6 1.71 For example, a 36 foot long, 6 volt circuit has (3) 9 watt heads spaced 12 feet apart. According to the wire run table, # 8 wire must be used (at 50 feet for a 5% voltage drop.) but, by multiplying the 31 feet for #10 wire by 1.5, a 461/2 foot wire run is acceptable, so #10 wire may be used and still meet the 5% voltage drop limitation. Note: According to the National Electrical Code, Article 720-Y, the smallest permissible wire size for systems under 50 volts is the #12 wire gauge. N 2N/ (n+1) 148 ARTICLE 700 – EMERGENCY SYSTEMS Peak load shaving operation shall be permitted for satisfying the test requirement of Section 700.3(B), provided all other conditions of Section 700.3 are met. A portable or temporary alternate source shall be available whenever the emergency generator is out of service for major maintenance or repair. I. General 700.1. Scope. The provisions of this article apply to the electrical safety of the installation, operation, and maintenance of emergency systems consisting of circuits and equipment intended to supply, distribute, and control electricity for illumination or power, or both, to required facilities when the normal electrical supply or system is interrupted. (FPN No. 1): For further information regarding wiring and installation of emergency systems in health care facilities, see Article 517. (FPN No. 2): For further information regarding performance and maintenance of emergency systems in health care facilities, see Standard for Health Care Facilities, NFPA 99-1999. (FPN No. 3): Emergency systems are generally installed in places of assembly where artificial illumination is required for safe exiting and for panic control in buildings subject to occupancy by large numbers of persons, such as hotels, theaters, sports arenas, health care facilities, and similar institutions. Emergency systems may also provide power for such functions as ventilation where essential to maintain life, fire detection and alarm systems, elevators, fire pumps, public safety communications systems, industrial processes where current interruption would produce serious life safety or health hazards, and similar functions. (FPN No. 4): For specification of locations where emergency lighting is considered essential to life safety, see Life Safety Code, NFPA 101-2000. (FPN No. 5): For further information regarding performance of emergency and standby power systems, see Standard for Emergency and Standby Power Systems, NFPA 1101999. 700.5. Transfer Equipment. (A) General. Transfer equipment, including automatic transfer switches, shall be automatic and identified for emergency use and approved by the authority having jurisdiction. Transfer equipment shall be designed and installed to prevent the inadvertent interconnection of normal and emergency sources of supply in any operation of the transfer equipment. Transfer equipment and electric power production systems installed to permit operation in parallel with the normal source shall meet the requirements of article 705. (B) Bypass Isolation Switches. Means shall be permitted to bypass and isolate the transfer equipment. Where bypass isolation switches are used, inadvertent parallel operation shall be avoided. (C) Automatic transfer switches shall be electrically operated and mechanically held. (D) Use. Transfer equipment shall supply only emergency loads. 700-6. Signals. A udible and visual signal devices shall be provided, where practicable, for the following purposes described in 700.6(A) through (D). (A) Derangement. To indicate derangement of the emergency source. (B) Carrying Load. To indicate that the battery is carrying load. (C) Not Functioning. To indicate that the battery charger is not functioning. (D) Ground Fault. To indicate a ground fault in solidly grounded wye emergency systems of more than 150 volts to ground and circuit protective devices rated 1000 amperes or more. The sensor for the ground-fault signal devices shall be located at, or ahead of, the main system disconnecting means for the emergency source, and the maximum setting of the signal devices shall be for a ground-fault current of 1200 amperes. Instructions on the course of action to be taken in event of indicated ground fault shall be located at or near the sensor location. 700.2. Definitions Emergency Systems. Those systems legally required and classed as emergency by municipal, state, federal or other codes, or by any governmental agency having jurisdiction. These systems are intended to automatically supply illumination, power or both, to designated areas and equipment in the event of failure of the normal supply or in the event of accident to elements of a system intended to supply, distribute, and control power and illumination essential for safety to human life. Informational Note: Emergency systems are generally installed in places of assembly where artificial illumination is required for safe exiting and for panic control in buildings subject to occupancy by large numbers of persons, such as hotels, theatres, sports, arenas, health care facilities, and similar institutions. Emergency systems may also provide power for such functions as ventilation where essential to maintain life, fire detection and alarm systems, elevators, fire pumps, public safety communications systems, industrial processes where current interruption would produce serious life safety or health hazards, and similar functions. Relay automatic Load Control. A device used to energize switched or normally-off lighting equipment from an emergency supply in the vent of loss of the normal supply, and to deenergize or return the equipment to normal status when the normal supply is restored. Informational Note: For requirements covering automatic load control relays, see ANSI/UL 924, Emergency Lighting and Power Equipment Informational Note: For signals for generator sets, see NFPA 110-2010, Standard for Emergency and Standby Power Systems 700.7. Signs. (A) Emergency Sources. A sign shall be placed at the service entrance equipment indicating type and location of on-site emergency power sources. Exception: A sign shall not be required for individual unit equipment as specified in Section 700-12(F). (B) Grounding. Where removal of a grounding or bonding connection in the normal power source equipement interrupts the grounding electrode conductor connection to the alternate power source(s) grounded conductor, a warning sign shall be installed at the normal power source equipment stating: WARNING SHOCK HAZARD EXISTS IF GROUNDING ELECTRODE CONDUCTOR OR BONDING JUMPER CONNECTION IN THIS EQUIPMENT IS REMOVED WHILE ALTERNATE SOURCE(S) IS ENERGIZED. 700.3.Tests and Maintenance. (A) Conduct or Witness Test. The authority having jurisdiction shall conduct or witness a test of the complete system upon installation and periodically afterward. (B) Tested Periodically. Systems shall be tested periodically on a schedule acceptable to the authority having jurisdiction to ensure the systems are maintained in proper operating condition. (C) Battery Systems Maintenance. Where battery systems or unit equipment are involved, including batteries used for starting, control, or ignition in auxiliary engines, the authority having jurisdiction shall require periodic maintenance. (D) Written Record. A written record shall be kept of such tests and maintenance. (E) Testing Under Load. Means for testing all emergency lighting and power systems during maximum anticipated load conditions shall be provided. II. Circuit Wiring 700-10. Wiring, Emergency System. (A) Identification. All boxes and enclosures (including transfer switches, generators, and power panels) for emergency circuits shall be permanently marked so they will be readily identified as a component of an emergency circuit or system. (B) Wiring. Wiring of two or more emergency circuits supplied from the same source shall be permitted in the same raceway, cable, box, or cabinet. Wiring from an emergency source distribution overcurrent protection to emergency loads shall be kept entirely independent of all other wiring and equipment, unless otherwise permitted in (1) through (5): (1) Wiring from the normal power source located in transfer equipment enclosures. (2) Wiring supplied from two sources in exit or emergency luminaires (3) W iring from two sources in a listed load control relay supplying exit or emergency luminaires, or in a common junction box, attached to exit or emergency luminaires (4) Wiring within a common junction box attached to unit equipment, containing only the branch circuit supplying the unit equipment and the emergency circuit supplied by the unit equipment. (5) W iring from an emergency source to supply any combination of emergency, legally required, or optional loads in accordance with (a), (b), (c) and (d): a. From separate vertical switchboard sections, with or without a common bus, or from individual disconnects mounted in separate enclosures. Informational Note: For requirements covering automatic load control relays, see ANSI/UL 024, Emergency Lighting and Power Equipment. 700.4. Capacity. (A) Capacity and Rating. An emergency system shall have adequate capacity and rating for all loads to be operated simultaneously. The emergency system equipment shall be suitable for the maximum available fault current at its terminals. (B) Selective Load Pickup, Load Shedding, and Peak Load Shaving. The alternate power source shall be permitted to supply emergency, legally required standby, and optional standby system loads where the source has adequate capacity or where automatic selective load pickup and load shedding is provided as needed to ensure adequate power to (1) the emergency circuits; (2) the legally required standby circuits; and (3) the optional standby circuits, in that order of priority. The alternate power source shall be permitted to be used for peak load shaving, provided the above conditions are met. 149 ACCESSORIES & GENERAL INFO. National Electrical Code ACCESSORIES & GENERAL INFO National Electrical Code b. The common bus or separate sections of the switchboard or the individual enclosures shall be permitted to be supplied by single or multiple feeders without overcurrent protection at the source Exception to (5)(b): Overcurrent protection shall be permitted at the source or for the equipment, provided the overcurrent protection complies with the requirements of 700.27 c. Legally required and optional standby circuits shall not originate from the same vertical switchboard section, panel board enclosure, or individual disconnect enclosure as emergency circuits. d. It shall be permissible to utilize single or multiple feeders to supply distribution equipment between an emergency source and the point where the combination of emergency, legally required, or optional loads are separated. (C) Wiring Design and Location. Emergency wiring circuits shall be designed and located to minimize the hazards that might cause failure due to flooding, fire, icing, vandalism, and other adverse conditions. (D) Fire Protection. Emergency systems shall meet the following additional requirements (D) (1) through (D)(3) in assembly occupancies for not less than 1000 persons or in buildings above 23 m (75 ft) in height with any of the following occupancy classes: assembly, educational, residential, detention and correctional, business, and mercantile. Batteries, whether of the acid or alkali type, shall be designed and constructed to meet the requirements of emergency service and shall be compatible with the charger for that particular installation. For a sealed battery, the container shall not be required to be transparent. However, for the lead acid battery that requires water additions, transparent or translucent jars shall be furnished. Automotive-type batteries shall not be used. An automatic battery charging means shall be provided. (B) Generator Set. (1) Prime Mover-Driven. For a generator set driven by a prime mover acceptable to the authority having jurisdiction and sized in accordance with Section 700-5. Means shall be provided for automatically starting the prime mover on failure of the normal service and for automatic transfer and operation of all required electrical circuits. A time-delay feature permitting a 15-minute setting shall be provided to avoid retransfer in case of short-time reestablishment of the normal source. (2) Internal Combustion Engines as Prime Movers. Where internal combustion engines are used as the prime mover an on-site fuel supply shall be provided with an on-premise fuel supply sufficient for not less than 2 hours full-demand operation of the system. Where power is needed for the operation of the fuel transfer pumps to deliver fuel to a generator set dry tank, this pump shall be connected to the emergency power system. (3) Dual Supplies. Prime movers shall not be solely dependent upon a public utility gas system for their fuel supply or municipal water supply for their cooling systems. Means shall be provided for automatically transferring from one fuel supply to another where dual fuel supplies are used. Exception: Where acceptable to the authority having jurisdiction, the use of other than on-site fuels shall be permitted where there is a low probability of a simultaneous failure of both the off-site fuel delivery system and power from the outside electrical utility company. (4) Where a storage battery is used for control or signal power, or as the means of starting the prime mover, it shall be suitable for the purpose and shall be equipped with an automatic charging means independent of the generator set. Where the battery charger is required for the operation of the generator set, it shall be connected to the emergency system. Where power is required for the operation of dampers used to ventilate the generator set, the dampers shall be connected to the emergency system. (5) Auxiliary Power Supply. Generator sets that require more than 10 seconds to develop power shall be permitted is an auxiliary power supply energizes the emergency system until the generator can pick up the load. (6) Outdoor Generator Sets. Where an outdoor housed generator set is equipped with a readily accessible disconnecting means located within sight of the building or structure supplied, an additional disconnecting means shall not be required where ungrounded conductors serve or pass through the building or structure. The disconnecting means shall meet the requirements of 225.36. Exception: For installations under single management where conditions of maintenance and supervision ensure that only qualified persons will monitor and service the installation and where documented safe switching procedures are established and maintained for disconnection, the generator set disconnecting means shall not be required to be located within sight of the building of structure served. Informational Note: For the definition of Occupancy Classification, see Section 6.1 of NFPA 101-2009, Life Safety Code (1) Feeder-circuit wiring shall meet one of the following conditions: (1) Be installed in spaces or areas that are fully protected by an approved automatic fire suppression system. Be listed electrical circuit protective system with a minimum 2-hour fire rating. (2) Informational note: UL guide information for electrical circuit protective systems (FHIT) contains information on proper installation requirements to maintain the fire rating (3) Be protected by a listed thermal barrier system for electrical system components with a minimum 2-hour fire rating. (4) Be protected by a listed fire-rated assembly that has a minimum fire rating of 2 hours and contains only emergency wiring circuits (5) Be encased in a minimum of 50 mm (2 in) of concrete (2) Feeder-Circuit Equipment. Equipment for feeder circuits (transfer switches, transformers, panel boards) shall be either located in spaces fully protected by approved automatic fire suppression systems ( including sprinklers and carbon dioxide systems) or in spaces with a 2-hour fire resistance rating. (3) Generator Control Wiring. Control conductors installed between the transfer equipment and the emergency generator shall be kept entirely independent of all other wiring and shall meet the conditions of 700.10(D)(1) III. Sources of Power 700.12. General Requirements. Current supply shall be such that, in the event of failure of the normal supply to, or within, the building or group of buildings concerned, emergency lighting, emergency power, or both will be available within the time required for the application but not to exceed 10 seconds. The supply system for emergency purposes, in addition to the normal services to the building and meeting the general requirements of this section, shall be one or more of the types of systems described in 700.12(A) through (D) below. Unit equipment in accordance with Section 700.12(E) shall satisfy the applicable requirements of this article. In selecting an emergency source of power, consideration shall be given to the occupancy and the type of service to be rendered, whether of minimum duration, as for evacuation of a theater, or longer duration, as for supplying emergency power and lighting due to an indefinite period of current failure from trouble either inside or outside the building. Equipment shall be designed and located to minimize the hazards that might cause complete failure due to flooding, fires, icing, and vandalism. Equipment for sources of power as described in Sections 700.12(A) through (E) where located within assembly occupancies for greater than 1000 persons or in buildings above 23 m (75 ft) in height with any of the following occupancy classes: assembly, educational, residential, detention and correctional, business, and mercantile, shall be installed either in spaces fully protected by approved automatic fire suppression systems (sprinklers, carbon dioxide systems, and so forth), or in spaces with a 1-hour fire rating. Informational note No. 1: For definition of Occupancy Classification, see Section 6.1of NFPA 101-2009, Life Safety Code. Informational note No. 2: Assignment of degree of reliability of the recognized emergency supply system depends on the careful evaluation of the variables at each particular installation. For further information, see ANSI/IEEE 493-2007, Recommended Practice for the Design of Reliable Industrial and Commercial Power Systems. (C) Uninterruptible Power Supplies. Uninterruptible power supplies used to provide power for emergency systems shall comply with the applicable provisions of Sections 700-12(A) and (B). (D) Separate Service. Where acceptable to the authority having jurisdiction as suitable for use as an emergency source of power, an additional service shall be permitted. This service shall be in accordance with the applicable provisions of Article 230 and following additional requirements. (1) Separate service drop or service lateral (2) Service conductors sufficiently remote electrically and physically from any other service conductors to minimize the possibility of simultaneous interruption of supply (E) Fuel Cell System. Fuel Cell Systems used as a source of power for emergency systems shall be of suitable rating and capacity to supply and maintain the total load for not less than 2 hours of full demand operation. Installation of a fuel cell system shall meet the requirements of Parts II through VIII of Article 692. Where a single fuel cell system serves as the normal supply for the building or group of buildings concerned, it shall not serve as the sole source of power for the emergency standby system. (F) Unit Equipment. Individual unit equipment for emergency illumination shall consist of the following: (1) A rechargeable battery (2) A battery charging means (3) Provisions for one or more lamps mounted on the equipment, or shall be permitted to have terminals for remote lamps, or both and (A) Storage Battery. Storage batteries used as source of power for emergency systems shall be of suitable rating and capacity to supply and maintain the total load for a period of 1 1/2 hours minimum, without the voltage applied to the load falling below 87 1/2 percent of normal. 150 (4) A relaying device arranged to energize the lamps automatically upon failure of the supply to the unit equipment. The batteries shall be of suitable rating and capacity to supply and maintain at not less than 87 1/2 percent of the nominal battery voltage for the total lamp load associated with the unit for a period of at least 1 1/2 hours, or the unit equipment shall supply and maintain not less than 60 percent of the initial emergency illumination for a period of at least 1 1/2 hours. Storage batteries, whether of the acid or alkali type, shall be designed and constructed to meet the requirements of emergency service. Unit equipment shall be permanently fixed in place (i.e., not portable) and shall have all wiring to each unit installed in accordance with the requirements of any of the wiring methods in Chapter 3. Flexible cord and plug connection shall be permitted, provided that the cord does not exceed 3 ft (900 mm) in length. The branch circuit feeding the unit equipment shall be the same branch circuit as that serving the normal lighting in the area and connected ahead of any local switches. The branch circuit that feeds unit equipment shall be clearly identified at the distribution panel. Emergency luminaire’s (illumination fixtures) that obtain power from a unit equipment and are not part of the unit equipment shall be wired to the unit equipment as required by Section 700-10 and by one of the wiring methods of Chapter 3. Exception No. 1: In a separate and uninterrupted area supplied by a minimum of three normal lighting circuits, a separate branch circuit for unit equipment shall be permitted if it originates from the same panelboard as that of the normal lighting circuits and is provided with a lock-on feature. Exception No. 2: Remote heads providing lighting for the exterior of an exit door shall be permitted to be supplied by the unit equipment serving the area immediately inside the exit door. 700.20. Switch Requirements. The switch or switches installed in emergency lighting circuits shall be arranged so that only authorized persons will have control of emergency lighting. Exception No. 1: Where two or more single-throw switches are connected in parallel to control a single circuit, at least one of these switches shall be accessible only to authorized persons. Exception No. 2: Additional switches that act only to put emergency lights into operation but not disconnect them shall be permissible. Switches connected in series or 3- and 4-way switches shall not be used. 700.21. Switch Location. All manual switches for controlling emergency circuits shall be in locations convenient to authorized persons responsible for their actuation. In facilities covered by Articles 518 and 520, a switch for controlling emergency lighting systems shall be located in the lobby or at a place conveniently accessible thereto. In no case shall a control switch for emergency lighting be placed in a motion-picture projection booth or on a stage or platform. Exception: Where multiple switches are provided, one such switch shall be permitted in such locations where arranged so that it can energize the circuit only, but cannot deenergize the circuit. 700.22. Exterior Lights. Those lights on the exterior of a building that are not required for illumination when there is sufficient daylight shall be permitted to be controlled by an automatic light-actuated device. 700.23 Dimmer Systems. A dimmer system containing more than one dimmer and listed for use in emergency systems shall be permitted to be used as a control device for energizing emergency lighting circuits. Upon failure of normal power, the dimmer system shall be permitted to selectively energize only those branch circuits required to provide minimum emergency illumination. All branch circuits supplied by the dimmer system cabinet shall comply with the wiring methods of Article 700. IV. Emergency System Circuits for Lighting and Power 700.15. Loads on Emergency Branch Circuits. No appliances and no lamps, other than those specified as required for emergency use, shall be supplied by emergency lighting circuits. 700.16. Emergency illumination. Emergency illumination shall include all required means of egress lighting, illuminated exit signs, and all other lights specified as necessary to provide required illumination. Emergency lighting systems shall be designed and installed so that the failure of any individual lighting element, such as the burning out of a light bulb, cannot leave in total darkness any space that requires emergency illumination. Where high-intensity discharge lighting such as high- and low-pressure sodium mercury vapor, and metal halide is used as the sole source of normal illumination, the emergency lighting system shall be required to operate until normal illumination has been restored. Exception: Where alterative means that ensure the emergency lighting illumination level is maintained shall be permitted. 700.24 Automatic Load Control Relay. If an emergency lighting load is automatically energized upon loss of the normal supply, a listed automatic load control relay shall be permitted to energize the load. The load control relay shall not be used to transfer equipment. VI. Overcurrent Protection 700-25. Accessibility. The branch-circuit overcurrent devices in emergency circuits shall be accessible to authorized persons only. (FPN): Fuses and circuit breakers for emergency circuit overcurrent protection where coordinated to ensure selective clearing of fault currents, increase overall reliability of the system. 700-26. Ground-Fault Protection of Equipment. The alternate source for emergency systems shall not be required to have ground-fault protection of equipment with automatic disconnecting means. ground-fault indication of the emergency source shall be provided in accordance with Section 700.6(D). 700.17. Branch Circuits for Emergency Lighting. Branch circuits that supply emergency lighting shall be installed to provide service from a source complying with Section 700-12 when the normal supply for lighting is interrupted. Such installations shall provide either one of the following: (1) An emergency lighting supply, independent of the normal lighting supply, with provisions for automatically transferring the emergency lights upon the event of failure of the normal lighting branch circuit (2) Two or more branch circuits supplied from separate and complete systems with independent power sources. One of the two power sources and systems shall be part of the emergency system and the other shall be permitted to be part of the normal power source and system. Each system shall provide sufficient power for emergency lighting purposes. Unless both systems are used for regular lighting purposes and are both kept lighted, means shall be provided for automatically energizing either system upon failure of the other. Either or both systems shall be permitted to be a part of the general lighting of the protected occupancy if circuits supplying lights for emergency illumination arc installed in accordance with other sections of this article. 700-27. Coordination. Emergency system(s) overcurrent devices shall be selectively coordinated with all supply side overcurrent protective devices. Exception: Selective coordination shall not be required between two overcurrent devices located in series if no loads are connected in parallel with the downstream device. National Electrical Code© 2011 National Electrical Code® is a registered trademark of the National Fire Protection Association 700.18. Circuits for Emergency Power. For branch circuits that supply equipment classed as emergency, there shall be an emergency supply source to which the load will be transferred automatically upon the failure of the normal supply. V. Control—Emergency Lighting Circuits 151 ACCESSORIES & GENERAL INFO. National Electrical Code ACCESSORIES & GENERAL INFO Life Safety Code 7.8 Illumination of Means of Egress. (4) Doors equipped with delayed-egress locks (5) Stair shafts and vestibules of smoke proof enclosures, for which the following also apply: (a) The stair shaft and vestibule shall be permitted to include a standby generator that is installed for the smoke proof enclosure mechanical ventilation equipment. (b) The standby generator shall be permitted to be used for the stair shaft and vestibule emergency lighting power supply. (6) New access-controlled egress doors in accordance with 7.2.1.6.2. 7.8.1 General. 7.8.1.1* Illumination of means of egress shall be provided in accordance with Section 7.8 for every building and structure where required in Chapters 11 through 43. For the purposes of this requirement, exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of this requirement, exit discharge shall include only designated stairs, aisles, corridors, ramps, escalators, walkways, and exit passageways leading to a public way. 7.9.1.2 For the purposes of 7.9.1.1, exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of 7.9.1.1, exit discharge shall include only designated stairs, ramps, aisles, walkways, and escalators leading to a public way. 7.8.1.2 Illumination of means of egress shall be continuous during the time that the conditions of occupancy require that the means of egress be available for use, unless otherwise provided in 7.8.1.2.2. 7.9.1.3 Where maintenance of illumination depends on changing from one energy source to another, a delay of not more than 10 seconds shall be permitted. 7.8.1.2.1 Artificial lighting shall be employed at such locations and for such periods of time as are necessary to maintain the illumination to the minimum criteria values herein specified. 7.9.2 Performance of System. 7.9.2.1* Emergency illumination shall be provided for a minimum of 11⁄2 hours in the event of failure of normal lighting. Emergency lighting facilities shall be arranged to provide initial illumination that is not less than an average of 1 ft-candle (10.8 lux) and, at any point, not less than 0.1 ft-candle (1.1 lux), measured along the path of egress at floor level. Illumination levels shall be permitted to decline to not less than an average of 0.6 ft-candle (6.5 lux) and, at any point, not less than 0.06 ft-candle (0.65 lux) at the end of 11⁄2 hours. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. 7.8.1.2.2 Unless prohibited by Chapters 11 through 43, automatic, motion sensor–type lighting switches shall be permitted within the means of egress, provided that the switch controllers comply with all of the following: (1) The switch controllers are listed. (2) The switch controllers are equipped for fail-safe operation, the and evaluated for this purpose. (3) The illumination timers are set for a minimum 15-minute duration, and the duration. (4) The motion sensor is activated by any occupant movement in the area served by the lighting units. (5) The switch controller is activated by activation of the building fire alarm system, if provided. 7.9.2.2 New emergency power systems for emergency lighting shall be at least Type 10, Class 1.5, Level 1, in accordance with NFPA110, Standard for Emergency and Standby Power Systems. 7.8.1.2.3* Energy-saving sensors, switches, timers, or controllers shall be approved and shall not compromise the continuity of illumination of the means of egress required by 7.8.1.2. 7.9.2.3* The emergency lighting system shall be arranged to provide the required illumination automatically in the event of any interruption of normal lighting due to any of the following: (1) Failure of a public utility or other outside electrical power supply (2) Opening of a circuit breaker or fuse (3) Manual act(s), including accidental opening of a switch controlling normal lighting facilities 7.8.1.3* The floors and other walking surfaces within an exit and within the portions of the exit access and exit discharge designated in 7.8.1.1 shall be illuminated as follows: (1) During conditions of stair use, the minimum illumination for new stairs shall be at least 10 ft-candle (108 lux), measured at the walking surfaces. (2) The minimum illumination for floors and walking surfaces, other than new stairs during conditions of stair use, shall be to values of at least 1 ft-candle (10.8 lux), measured at the floor. (3) In assembly occupancies, the illumination of the walking surfaces of exit access shall be at least 0.2 ft-candle (2.2 lux) during periods of performances or projections involving directed light. (4)*The minimum illumination requirements shall not apply where operations or processes require low lighting levels. 7.9.2.4 Emergency generators providing power to emergency lighting systems shall be installed, tested, and maintained in accordance with NFPA 110, Standard for Emergency and Standby Power Systems. Stored electrical energy systems, where required in this Code, other than battery systems for emergency luminaires in accordance with 7.9.2.5, shall be installed and tested in accordance with NFPA 111, Standard on Stored Electrical Energy Emergency and Standby Power Systems. 7.9.2.5 Unit equipment and battery systems for emergency luminaires shall be listed to ANSI/ UL 924, Standard for Emergency Lighting and Power Equipment. 7.8.1.4* Required illumination shall be arranged so that the failure of any single lighting unit does not result in an illumination level of less than 0.2 ft-candle (2.2 lux) in any designated area. 7.9.2.6* Existing battery-operated emergency lights shall use only reliable types of rechargeable batteries provided with suitable facilities for maintaining them in properly charged condition. Batteries used in such lights or units shall be approved for their intended use and shall comply with NFPA 70, National Electrical Code. 7.8.1.5 The equipment or units installed to meet the requirements of Section 7.10 also shall be permitted to serve the function of illumination of means of egress, provided that all requirements of Section 7.8 for such illumination are met. 7.9.2.7 The emergency lighting system shall be either continuously in operation or shall be capable of repeated automatic operation without manual intervention. 7.9.3 Periodic Testing of Emergency Lighting Equipment. 7.8.2 Sources of Illumination. 7.8.2.1* Illumination of means of egress shall be from a source considered reliable by the authority having jurisdiction. 7.8.2.2 Battery-operated electric lights and other types of portable lamps or lanterns shall not be used for primary illumination of means of egress. Battery-operated electric lights shall be permitted to be used as an emergency source to the extent permitted under Section 7.9. 7.9.3.1 Required emergency lighting systems shall be tested in accordance with one of the three options offered by 7.9.3.1.1, 7.9.3.1.2, or 7.9.3.1.3. 7.9.3.1.1 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Functional testing shall be conducted monthly, with a minimum of 3 weeks and a maximum of 5 weeks between tests, for not less than 30 seconds, except as otherwise permitted by 7.9.3.1.1(2). (2)* The test interval shall be permitted to be extended beyond 30 days with the approval of the authority having jurisdiction. (3) Functional testing shall be conducted annually for a minimum of 11⁄2 hours if the emergency lighting system is battery powered. (4) The emergency lighting equipment shall be fully operational for the duration of the tests required by 7.9.3.1.1(1) and (3). (5) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction. 7.9 Emergency Lighting. 7.9.1 General. 7.9.1.1* Emergency lighting facilities for means of egress shall be provided in accordance with Section 7.9 for the following: (1) Buildings or structures where required in Chapters 11 through 43 (2) Underground and limited access structures as addressed in Section 11.7 (3) High-rise buildings as required by other sections of this Code 152 7.9.3.1.2 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall be provided. (2) Not less than once every 30 days, self-testing/self-diagnostic battery-operated emergency lighting equipment shall automatically perform a test with a duration of a minimum of 30 seconds and a diagnostic routine. (3) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall indicate failures by a status indicator. (4) A visual inspection shall be performed at intervals not exceeding 30 days. (5) Functional testing shall be conducted annually for a minimum of 1-1/2 hours. (6) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall be fully operational for the duration of the 11⁄2-hour test. (7) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction. 7.10.1.5.2* New sign placement shall be such that no point in an exit access corridor is in excess of the rated viewing distance or 100 ft (30 m), whichever is less, from the nearest sign. 7.10.1.6* Floor Proximity Exit Signs. Where floor proximity exit signs are required in Chapters 11 through 43, such signs shall comply with 7.10.3, 7.10.4, 7.10.5, and 7.10.6 for externally illuminated signs and 7.10.7 for internally illuminated signs. Such signs shall be located near the floor level in addition to those signs required for doors or corridors. The bottom of the sign shall be not less than 6 in. (150 mm), but not more than 18 in.(455 mm), above the floor. For exit doors, the sign shall be mounted on the door or adjacent to the door, with the nearest edge of the sign within 4 in. (100 mm) of the door frame. 7.10.1.7* Floor Proximity Egress Path Marking. Where floor proximity egress path marking is required in Chapters 11 through 43, an approved floor proximity egress path marking system that is internally illuminated shall be installed within 18 in. (455 mm) of the floor. Floor proximity egress path marking systems shall be listed in accordance with ANSI/UL 1994, Standard for Luminous Egress Path Marking Systems. The system shall provide a visible delineation of the path of travel along the designated exit access and shall be essentially continuous, except as interrupted by doorways, hallways, corridors, or other such architectural features. The system shall operate continuously or at any time the building fire alarm system is activated. The activation, duration, and continuity of operation of the system shall be in accordance with 7.9.2. The system shall be maintained in accordance with the product manufacturing listing. 7.9.3.1.3 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Computer-based, self-testing/self-diagnostic battery-operated emergency lighting equipment shall be provided. (2) Not less than once every 30 days, emergency lighting equipment shall automatically perform a test with a duration of a minimum of 30 seconds and a diagnostic routine. (3) The emergency lighting equipment shall automatically perform annually a test for a minimum of 11⁄2 hours. (4) The emergency lighting equipment shall be fully operational for the duration of the tests required by 7.9.3.1.3(2) and (3). (5) The computer-based system shall be capable of providing a report of the history of tests and failures at all times. 7.10.1.8* Visibility. Every sign required in Section 7.10 shall be located and of such size, distinctive color, and design that it is readily visible and shall provide contrast with decorations, interior finish, or other signs. No decorations, furnishings, or equipment that impairs visibility of a sign shall be permitted. No brightly illuminated sign (for other than exit purposes), display, or object in or near the line of vision of the required exit sign that could detract attention from the exit sign shall be permitted. 7.10 Marking of Means of Egress. 7.10.1.9 Mounting Location. The bottom of new egress markings shall be located at a vertical distance of not more than 6 ft 8 in. (2030 mm) above the top edge of the egress opening intended for designation by that marking. Egress markings shall be located at a horizontal distance of not more than the required width of the egress opening, as measured from the edge of the egress opening intended for designation by that marking to the nearest edge of the marking. 7.10.1 General. 7.10.1.1 Where Required. Means of egress shall be marked in accordance with Section 7.10 where required in Chapters 11 through 43. 7.10.1.2 Exits. 7.10.1.2.1* Exits, other than main exterior exit doors that obviously and clearly are identifiable as exits, shall be marked by an approved sign that is readily visible from any direction of exit access. 7.10.2 Directional Signs. 7.10.2.1* A sign complying with 7.10.3, with a directional indicator showing the direction of travel, shall be placed in every location where the direction of travel to reach the nearest exit is not apparent. 7.10.1.2.2* Horizontal components of the egress path within an exit enclosure shall be marked by approved exit or directional exit signs where the continuation of the egress path is not obvious. 7.10.1.3 Exit Door Tactile Signage. Tactile signage shall be provided to meet all of the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT. (3) Tactile signage shall comply with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities. 7.10.1.4 Existing Exemption. The requirements of 7.10.1.3 shall not apply to existing buildings, provided that the occupancy classification does not change. 7.10.1.5 Exit Access. 7.10.1.5.1 Access to exits shall be marked by approved, readily visible signs in all cases where the exit or way to reach the exit is not readily apparent to the occupants. 153 ACCESSORIES & GENERAL INFO. Life Satefy Code ACCESSORIES & GENERAL INFO Life Safety Code 7.10.6.2.1 Chevron Type Indicator. 7.10.2.2 Directional exit signs shall be provided within horizontal components of the egress path within exit enclosures as required by 7.10.1.2.2. 7.10.6.2.2 The requirements of 7.10.6.2.1 shall not apply to approved existing signs. 7.10.3* Sign Legend. 7.10.3.1 Signs required by 7.10.1 and 7.10.2 shall read as follows in plainly legible letters, or other appropriate wording shall be used: 7.10.6.3* Level of Illumination. Externally illuminated signs shall be illuminated by not less than 5 ft-candles (54 lux) at the illuminated surface and shall have a contrast ratio of not less than 0.5. EXIT 7.10.7 Internally Illuminated Signs. 7.10.7.1 Listing. Internally illuminated signs shall be listed in accordance with ANSI/UL 924, Standard for Emergency Lighting and Power Equipment, unless they meet one of the following criteria: (1) They are approved existing signs. (2) They are existing signs having the required wording in legible letters not less than 4 in. (100 mm) high. (3) They are signs that are in accordance with 7.10.1.3 and 7.10.1.6. 7.10.3.2* Where approved by the authority having jurisdiction, pictograms in compliance with NFPA 170, Standard for Fire Safety and Emergency Symbols, shall be permitted. 7.10.4* Power Source. Where emergency lighting facilities are required by the applicable provisions of Chapters 11 through 43 for individual occupancies, the signs, other than approved self-luminous signs and listed photoluminescent signs in accordance with 7.10.7.2, shall be illuminated by the emergency lighting facilities. The level of illumination of the signs shall be in accordance with 7.10.6.3 or 7.10.7 for the required emergency lighting duration as specified in 7.9.2.1. However, the level of illumination shall be permitted to decline to 60 percent at the end of the emergency lighting duration. 7.10.7.2* Photoluminescent Signs. The face of a photoluminescent sign shall be continually illuminated while the building is occupied. The illumination levels on the face of the photoluminescent sign shall be in accordance with its listing. The charging illumination shall be a reliable light source, as determined by the authority having jurisdiction. The charging light source, shall be of a type specified in the product markings. 7.10.8 Special Signs. 7.10.8.1 Sign Illumination. 7.10.5 Illumination of Signs. 7.10.5.1* General. Every sign required by 7.10.1.2, 7.10.1.5, or 7.10.8.1, other than where operations or processes require low lighting levels, shall be suitably illuminated by a reliable light source. Externally and internally illuminated signs shall be legible in both the normal and emergency lighting mode. 7.10.8.1.1 Where required by other provisions of this Code, special signs shall be illuminated in accordance with 7.10.5, 7.10.6.3, and 7.10.7. 7.10.8.1.2 Where emergency lighting facilities are required by the applicable provisions of Chapters 11 through 43, the required illumination of special signs shall additionally be provided under emergency lighting conditions. 7.10.5.2* Continuous Illumination. 7.10.5.2.1 Every sign required to be illuminated by 7.10.6.3, 7.10.7, and 7.10.8.1 shall be continuously illuminated as required under the provisions of Section 7.8, unless otherwise provided in 7.10.5.2.2. 7.10.8.2 Characters. Special signs, where required by other provisions of this Code, shall comply with the visual character requirements of ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities. 7.10.5.2.2* Illumination for signs shall be permitted to flash on and off upon activation of the fire alarm system. 7.10.6 Externally Illuminated Signs. 7.10.6.1* Size of Signs. 7.10.8.3* No Exit. 7.10.8.3.1 Any door, passage, or stairway that is neither an exit nor a way of exit access and that is located or arranged so that it is likely to be mistaken for an exit shall be identified by a sign that reads as follows: 7.10.6.1.1 Externally illuminated signs required by 7.10.1 and 7.10.2, other than approved existing signs, unless otherwise provided in 7.10.6.1.2, shall read EXIT or shall use other appropriate wording in plainly legible letters sized as follows: (1) For new signs, the letters shall be not less than 6 in. (150 mm) high, with the principal strokes of letters not less than 3⁄4 in. (19 mm) wide. (2) For existing signs, the required wording shall be permitted to be in plainly legible letters not less than 4 in. (100 mm) high. (3) The word EXIT shall be in letters of a width not less than 2 in. (51 mm), except the letter I, and the minimum spacing between letters shall be not less than 3⁄8 in. (9.5 mm). (4) Sign legend elements larger than the minimum established in 7.10.6.1.1(1) through (3) shall use letter widths, strokes, and spacing in proportion to their height. NO EXIT 7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 2 in. (51 mm) high, with a stroke width of 3⁄8 in. (9.5 mm), and the word EXIT in letters 1 in. (25 mm) high, with the word EXIT below the word NO, unless such sign is an approved existing sign. 7.10.8.4 Elevator Signs. Elevators that are a part of a means of egress (see 7.2.13.1) shall have both of the following signs with a minimum letter height of 5⁄8 in. (16 mm) posted in every elevator lobby: (1) *Signs that indicate that the elevator can be used for egress, including any restrictions on use (2) *Signs that indicate the operational status of elevators 7.10.6.1.2 The requirements of 7.10.6.1.1 shall not apply to marking required by 7.10.1.3 and 7.10.1.7. 7.10.8.5* Evacuation Diagram. Where a posted floor evacuation diagram is required in Chapters 11 through 43, floor evacuation diagrams reflecting the actual floor arrangement and exit locations shall be posted and oriented in a location and manner acceptable to the authority having jurisdiction. 7.10.6.2* Size and Location of Directional Indicator. 7.10.6.2.1 Directional indicators, unless otherwise provided in 7.10.6.2.2, shall comply with all of the following: (1) The directional indicator shall be located outside of the EXIT legend, not less than 3⁄8 in. (9.5 mm) from any letter. (2) The directional indicator shall be of a chevron type, as shown in Figure 7.10.6.2.1. (3) The directional indicator shall be identifiable as a directional indicator at a distance of 40 ft (12 m). (4) A directional indicator larger than the minimum established for compliance with 7.10.6.2.1(3) shall be proportionately increased in height, width, and stroke. (5) The directional indicator shall be located at the end of the sign for the direction indicated. 7.10.9 Testing and Maintenance. 7.10.9.1 Inspection. Exit signs shall be visually inspected for operation of the illumination sources at intervals not to exceed 30 days or shall be periodically monitored in accordance with 7.9.3.1.3. 7.10.9.2 Testing. Exit signs connected to, or provided with, a battery-operated emergency illumination source, where required in 7.10.4, shall be tested and maintained in accordance with 7.9.3. 154 1.0 EMERGI-LITE® 6, 12 and 24 volt Emergency Lighting Unit Equipment (excluding lamps and fuses) are fully warranted to be free of defects in material and workmanship under normal use for a period of three years from date of installation (see Paragraph 2.0). 1.1 EMERGI-LITE® 6, 12 and 24 volt Unit Equipment Batteries are warranted as follows (Warrant below includes the 3-year full warranty on entire unit as called out in Paragraph 1.0). 1.2 EMERGI-LITE® volt Emergency Lighting Unit Equipment (excluding lamps, and fuses) is fully warranted to be free of defects in material and workmanship under normal use for a period of one year from date of installation (see Paragraph 2.0). BATTERY TYPE Sealed Lead-Calcium LIFE EXPECTANCY 8 years SHELF LIFE* 6 months FULL WARRANTY 3 years PRO RATA WARRANTY 3 years Sealed Lead-Calcium (Immobilized Electrolyte) 12 years 6 months 5 years 5 years Sealed Long Life Lead 12 years 6 months 5 years 5 years Sealed Nickel-Cadmium 15 years 1 year 5 years 7 years Refillable Lead-Calcium 15 years 6 months 3 years 8 years Refillable Nickel-Cadmium 15 years 2 years 5 years 7 years *Maximum Storage life. Must Be Recharged If Not Placed in Service Or Battery Warranty Void 2.0 The full warranty period begins on the date of installation or 90 days from date of shipment, whichever date is earlier. 2.1 Should a defect appear in the equipment or batteries listed in Paragraphs 1.0, 1.1 or 1.2 above within the specified full warranty period, Emergi-Lite® will repair or replace equipment without charge (see Paragraph 3.3). Such repair or replacement shall be the purchaser’s exclusive remedy. 2.2 The Pro Rata Warranty Period for batteries begins on the date the full warranty period ends. 2.3 A battery determined to be defective during the Pro Rata Warranty Period shall be repaired or replaced at a cost equal to the net price in effect at the time, reduced by the percentage obtained in multiplying 10% by the number of full years remaining in the total warranty period. Such repair or replacement at this adjusted price shall be the purchaser’s exclusive remedy. 3.0 All warranties are subject to proper installation and maintenance in accordance with the instructions supplied. 3.1 Any material deemed defective must be returned, freight prepaid, to the factory for evaluation (see Paragraph 5.0-5.3). Any changes in circuitry or components by other than authorized Emergi-Lite® personnel or its service companies will void the warranty. 3.2 All warranties are limited to the repair and/or replacement or parts or equipment, which, upon examination at our plant, are determined to be defective and in our judgement are subject to repair or replacement under warranty. Replacement of lamps and fuses is not included in the warranty. 3.3 If new replacement parts are shipped before defective goods are received for evaluation, the replacement parts will be invoiced at the net price in effect at that time. These charges will be credited if, upon receipt and evaluation of goods, a defect is determined. Only replacement parts will be shipped under these circumstances, if field replacement is possible. EMERGI-LITE® FACTORY ONLY RESERVES THE RIGHT TO SHIP NEW UNIT EQUIPMENT FOR REPLACEMENT PURPOSES. Units returned after installation cannot be restored to 100% saleable condition. 4.0 In no event shall Emergi-Lite® be liable for backcharges of any kind, including, without limitation, labor charges for field repair or late penalties. 4.1 This warranty does not cover damages caused by improper maintenance of installation or damage due to installation in areas with other than normal temperatures and environmental conditions per application specifications. Emergi-Lite® assumes no responsibility for any damage to people, property, apparatus or otherwise resulting from improper installation or maintenance of its Emergency Lighting Unit Equipment. 4.2 This warranty does not cover damages caused by abuse, fire or Act of God. 4.3 In no event shall Emergi-Lite® be liable for incidental or consequential damages. 4.4 The foregoing warranty is in lieu of all other warranties, expressed or implied, or merchantability, fitness for a particular purpose or any other thing. Except as stated in this warranty, Emergi-Lite® shall not be liable for any defects in, or breach of any contract relating to, the quality of performance of Emergi-Lite® Equipment under any theory of law including, without limitation, contract, negligence, strict liability or misrepresentation. 4.5 Emergi-Lite® warranty coverage shall not apply to any equipment of another manufacturer used in conjunction with Emergi-Lite® Equipment. 4.6 Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This written warranty gives you specific legal rights and you may also have other rights which vary from state to state. 5.0 No returned defective materials will be accepted without a Returned Goods Authorization issued in writing by an authorized Emergi-Lite® employee. 5.1 Purchaser is responsible for secure packing of returned materials to provide best possible assurance against damage in shipment. 5.2 Defective batteries of any kind must not be returned to Emergi-Lite’s® factory without strict adherence to special instructions for handling and shipping. WARNING Never ship a refillable wet battery in any type of emergency lighting equipment. Failure to adhere to this policy will void warranty. 5.3 Defective goods returned to the factory must be shipped prepaid. COLLECT RETURNED SHIPMENT WILL BE REFUSED. Freight charges to return repaired equipment or ship replacement equipment to the purchaser to be paid by Emergi-Lite®. Factory will return repaired goods via same shipping method as received. FAILURE TO COMPLY WITH ANY OF THE STIPULATIONS SET FORTH WILL VOID THE WARRANTY. ANY EXCEPTIONS TO THE FOREGOING WARRANTY MUST BE REQUESTED AND ACCEPTED IN WRITING PRIOR TO SHIPMENT. Emergi-lite® EQUIPMENT NOT LISTED IN PARAGRAPHS 1.0, 1.1 OR 1.2 IS WARRANTED AS DESCRIBED ON ITS INDIVIDUAL DATA SHEET WITH THE STIPULATIONS AS STATED IN PARAGRAPHS 2.0-5.3. 155 ACCESSORIES & GENERAL INFO. Limited Warranty ACCESSORIES & GENERAL INFO Product Index Series. . . . . . . . . . . . . . . . . . . . . . Page Series. . . . . . . . . . . . . . . . . . . . . . Page Series. . . . . . . . . . . . . . . . . . . . . . Page (negative)TS. . . . . . . . . . . . . . . . . . . . . . . 71 12804-E. . . . . . . . . . . . . . . . . . . . . . . . . 145 12805-E. . . . . . . . . . . . . . . . . . . . . . . . . 145 12HZM. . . . . . . . . . . . . . . . . . . . . . . . . . . 59 12ILS. . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 12JAC . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 12JAM. . . . . . . . . . . . . . . . . . . . . . . . . . . 37 12JCC. . . . . . . . . . . . . . . . . . . . . . . . . . . 36 12JCM. . . . . . . . . . . . . . . . . . . . . . . . . . . 36 12JSC . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 12JSE . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 12JSM. . . . . . . . . . . . . . . . . . . . . . . . . . . 39 12K . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 12KS . . . . . . . . . . . . . . . . . . . . . . . . . 68-69 12LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 12LSC. . . . . . . . . . . . . . . . . . . . . . . . . . . 43 12LSE . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 12LSM. . . . . . . . . . . . . . . . . . . . . . . . . . . 43 12PR. . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 12PS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 12RSC. . . . . . . . . . . . . . . . . . . . . . . . . . . 17 12RSE. . . . . . . . . . . . . . . . . . . . . . . . . . . 17 12RSM. . . . . . . . . . . . . . . . . . . . . . . . . . . 17 12SV . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 12TSC. . . . . . . . . . . . . . . . . . . . . . . . . . . 19 12TSE . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 12TSM. . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1EXC. . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 230.1238-E . . . . . . . . . . . . . . . . . . . . . . 145 230.1239-E . . . . . . . . . . . . . . . . . . . . . . 145 24ILS. . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 24KS . . . . . . . . . . . . . . . . . . . . . . . . 66, 67 24LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 24LSC. . . . . . . . . . . . . . . . . . . . . . . 42, 43 24LSE . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 24LSM. . . . . . . . . . . . . . . . . . . . . . . . 42, 43 24TSC. . . . . . . . . . . . . . . . . . . . . . . . 18, 19 24TSE . . . . . . . . . . . . . . . . . . . . . . . . 18, 19 24TSM. . . . . . . . . . . . . . . . . . . . . . . . 18, 19 330.7583-E . . . . . . . . . . . . . . . . . . . . . . 145 330.7584-E . . . . . . . . . . . . . . . . . . . . . . 145 430.0765-E . . . . . . . . . . . . . . . . . . . . . . 145 430.0766-E . . . . . . . . . . . . . . . . . . . . . . 145 450.0129-E . . . . . . . . . . . . . . . . . . . . . . 145 450.0397-E . . . . . . . . . . . . . . . . . . . . . . 145 450.0398-E . . . . . . . . . . . . . . . . . . . . . . 145 6HZM24. . . . . . . . . . . . . . . . . . . . . . . . . . 59 B1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 B12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 DLM-2. . . . . . . . . . . . . . . . . . . . . . . . . . 106 DX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 DXN. . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 EC. . . . . . . . . . . . . . . . . . . . . . . . . . 34, 35 ECX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 EF10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 EF11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 EF13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 EF14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 EF15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 EF150 . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 EF17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 EF18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 EF21R . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 EF23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 EF24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 EF24-2. . . . . . . . . . . . . . . . . . . . . . . . . . . 89 EF28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 EF32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 EF35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 EF39 . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 EF39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 EF39D . . . . . . . . . . . . . . . . . . . . . . . . . . 98 EF39D . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 EF41 . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 EF41D . . . . . . . . . . . . . . . . . . . . . . . . . . 99 EF9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 EFEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 EFR2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 EFR8R. . . . . . . . . . . . . . . . . . . . . . . . . . . 83 EFXP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 EL-2MRS. . . . . . . . . . . . . . . . . . . . . . . . 110 EL-2MRS-LA . . . . . . . . . . . . . . . . . . . . . 110 EL-2SQ . . . . . . . . . . . . . . . . . . . . . . . . . 108 ELX400 . . . . . . . . . . . . . . . . . . . . . . . . . 105 ELXN400. . . . . . . . . . . . . . . . . . . . . . . 112 EXC. . . . . . . . . . . . . . . . . . . . . . . . . . 70-71 FPDL . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 FPS . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 GS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 GS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 ILC. . . . . . . . . . . . . . . . . . . . . . . . . . . 64, 65 ILS. . . . . . . . . . . . . . . . . . . . . . . . . . . 64, 65 JAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 JAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 JCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 JCM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 JSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 JSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 JSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 KS . . . . . . . . . . . . . . . . . . . . . . . . . . 65, 67 LS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 LEDP. . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 LEDPXN. . . . . . . . . . . . . . . . . . . . . . . . . . 49 LED-RX . . . . . . . . . . . . . . . . . . . . . . . . . 113 LL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 LSC. . . . . . . . . . . . . . . . . . . . . . . . . 42, 43 LSE . . . . . . . . . . . . . . . . . . . . . . . . . 42, 43 LSM. . . . . . . . . . . . . . . . . . . . . . . . . 42, 43 LSNX. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 LUX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 LUXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 LUXN. . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 LUXN2. . . . . . . . . . . . . . . . . . . . . . . . . . . 13 LX. . . . . . . . . . . . . . . . . . . . . . . . . 22, 23, 24 LXN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 MP12. . . . . . . . . . . . . . . . . . . . . . . . . . . 144 MP24. . . . . . . . . . . . . . . . . . . . . . . . . . . 144 MP3. . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 MP6. . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 MRT. . . . . . . . . . . . . . . . . . . . . . . . . . 15, 81 MRT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 P . . . . . . . . . . . . . . . . . . . . . . . . . . . 48, 50 P2C1. . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 P2C2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 PDN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 PE . . . . . . . . . . . . . . . . . . . . . . . . . . 46, 47 PEN. . . . . . . . . . . . . . . . . . . . . . . . . 46, 47 PES. . . . . . . . . . . . . . . . . . . . . . . . . 46, 47 PNEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 PNEXRF. . . . . . . . . . . . . . . . . . . . . . . . . . 48 PR. . . . . . . . . . . . . . . . . . . . . . . . . . 30, 31 PREM. . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 PRO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 PS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 PU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 PXN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 RSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 RSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 RSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 RT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 RTG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 RTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 RTS-1. . . . . . . . . . . . . . . . . . . . . . . . . . . 144 SLX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 SV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 SVX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 SVX12N. . . . . . . . . . . . . . . . . . . . . . . . . . 57 SVX24N. . . . . . . . . . . . . . . . . . . . . . . . . . 57 SVXH. . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 SVXHZ. . . . . . . . . . . . . . . . . . . . . . . . . . . 62 SVXN. . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 SVXNHZ. . . . . . . . . . . . . . . . . . . . . . . . . . 62 TSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 TSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 TSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 TX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 TXN . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 VRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 VRS-4X . . . . . . . . . . . . . . . . . . . . . . . . . 144 VRS-BB. . . . . . . . . . . . . . . . . . . . . . . . . 144 VRSBB-4X. . . . . . . . . . . . . . . . . . . . . . . 144 WG10-E. . . . . . . . . . . . . . . . . . . . . . . . . 143 WG11-E. . . . . . . . . . . . . . . . . . . . . . . . . 143 WG12-E. . . . . . . . . . . . . . . . . . . . . . . . . 143 WG13-E. . . . . . . . . . . . . . . . . . . . . . . . . 143 WG1-E. . . . . . . . . . . . . . . . . . . . . . . . . . 142 WG2-E. . . . . . . . . . . . . . . . . . . . . . . . . . 142 WG3-E. . . . . . . . . . . . . . . . . . . . . . . . . . 142 WG4-E. . . . . . . . . . . . . . . . . . . . . . . . . . 142 WG5-E. . . . . . . . . . . . . . . . . . . . . . . . . . 142 WG6-E. . . . . . . . . . . . . . . . . . . . . . . . . . 142 WG7-E. . . . . . . . . . . . . . . . . . . . . . . . . . 142 WG8-E. . . . . . . . . . . . . . . . . . . . . . . . . . 142 WG9-E. . . . . . . . . . . . . . . . . . . . . . . . . . 143 156
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2014:05:30 09:48:33-04:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2014:05:30 09:55:25-04:00 Title : Trapped : False Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2014:05:30 09:55:25-04:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Document ID : uuid:9d1ee55c-a441-4c4b-9a7a-f2fe6d63c2b0 Instance ID : uuid:041abfc5-5b5c-441e-99d1-05805a6ac7af Producer : Adobe PDF Library 10.0.1 Page Count : 149EXIF Metadata provided by EXIF.tools