29636 Catalog

231324-Catalog 1 231324-Catalog_1 231324-Catalog_1 782113 Batch5 unilog cesco-content

2014-07-04

: Pdf 29636-Catalog 29636-Catalog 010781 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 71

Download29636-Catalog
Open PDF In BrowserView PDF
Product Guide

Loadcentres
Circuit Breakers
Generator Panels

Spa Panels
Surge Suppressors
Street Lighting Panels

Mini-Power Centres
Fuse Panel Inserts
Pressure Switches

Residential &
Light Commercial
Distribution
Products

Residential & Light Commercial Distribution Products

	

	 	

Type CPM/CPL Plug-In Loadcentres
Type CPM/CPL Plug-In Loadcentres............................................................................................. 1

	 	

Type CPM Plug-In Loadcentres
Combination (Main Circuit Breaker) Single Phase Type 1............................................................ 2
Combination (Main Circuit Breaker) Single Phase Type 3R.......................................................... 3
Combination (Main Circuit Breaker) Three Phase Type 1............................................................. 4
Combination (Main Circuit Breaker) Three Phase Type 3R........................................................... 5

	 	

Type CPL Plug-In Loadcentres
Non-Combination (Main Lug Only) Single Phase Type 1.............................................................. 6
Non-Combination (Main Lug Only) Single Phase Type 3R............................................................ 7
Non-Combination (Main Lug Only) Three Phase Type 1............................................................... 8
Non-Combination (Main Lug Only) Three Phase Type 3R............................................................ 9
Non-Combination (Main Lug Only) 70A Single Phase................................................................ 10

	 	

Type CPM/CPL Plug-In Loadcentre Accessories
Type CPM/CPL Plug-In Loadcentre Accessories........................................................................ 11

	 	

Plug-In Circuit Breakers for CPM/CPL
Type BR Single & Multi-Pole...................................................................................................... 13
Type DNPL Duplex™, Independent Quadplex™, & Circuit Breaker Packs................................ 14
Type BR Arc Fault Circuit Interrupter.......................................................................................... 15
Type GFCB and GFEP Ground Fault........................................................................................... 16
Type BR Internationally Rated.................................................................................................... 17
Type GFXB Internationally Rated Ground Fault & Type BR Moulded Case Switches................ 18

	 	

Plug-In Loadcentre Main Circuit Breakers for CPM/CPL
Type CSR, BWH, & CC............................................................................................................... 19

	 	

Plug-In Circuit Breaker Accessories for CPM/CPL Loadcentres
Accessories for Types BR, DNPL, GFCB, GFEP, GFXB, CSR, BWH, & CC................................ 20

	 	

Plug-In OEM Loadcentre Interior Assemblies
Plug-In OEM Loadcentre Interior Assemblies............................................................................ 21

	 	

Type CH Plug-In Loadcentres
Combination & Non-Combination Single Phase......................................................................... 26

	 	

Plug-In Circuit Breakers for CH
Type CH Single, Multi-Pole, & Twin........................................................................................... 27
Type CHP Commercial .............................................................................................................. 28
Type CH Arc Fault Circuit Interrupter......................................................................................... 29
Type CH Ground Fault................................................................................................................ 30

	 	

Plug-In Loadcentre Main Circuit Breakers for CH
Type CSH.................................................................................................................................... 31

	 	

Plug-In Loadcentre & Circuit Breaker Accessories for CH
Type CH Accessories.................................................................................................................. 32

	 	

Type CBM Bolt-On Loadcentres
Combination (Main Circuit Breaker) Single & Three Phase Aluminum Bus................................ 33
Combination (Main Circuit Breaker) Single & Three Phase Copper Bus..................................... 34

	 	

Type CBL Bolt-On Loadcentres
Non-Combination (Main Lug Only) Single & Three Phase Aluminum Bus................................. 35
Non-Combination (Main Lug Only) Single & Three Phase Copper Bus...................................... 36

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	



Residential & Light Commercial Distribution Products

	 	

Bolt-On Circuit Breakers for CBM/CBL
Type BAB & QBHW Single and Multi-Pole................................................................................. 37
Type QBA Arc Fault Circuit Interrupter & DNBA Duplex............................................................ 38
Type GFCBB and QBGFEP Ground Fault .................................................................................. 39

	 	

Bolt-On Loadcentre and Circuit Breaker Accessories
Bolt-On Loadcentre and Circuit Breaker Accessories................................................................. 40

	 	

Manual Transfer Switches / Generator Panels
Manual Transfer Switches / Generator Panels........................................................................... 41

	 	

Spa Panels
Spa Panels.................................................................................................................................. 43

	 	

Surge Suppression Products
Stage 1 & Stage 1 Type 2........................................................................................................... 44
Stage 2 & Accessories............................................................................................................... 45
Type 1......................................................................................................................................... 46

	 	

Street Lighting Panels
In-Pole......................................................................................................................................... 47
On-Pole....................................................................................................................................... 48
Pedestal...................................................................................................................................... 49

	 	

Combined Loadcentre and Meter Socket
Combined Loadcentre and Meter Socket................................................................................... 50

	 	

Metered Temporary Ground Fault Power Panel
Metered Temporary Ground Fault Power Panel......................................................................... 51

	 	

Mini-Power Centres
Plug-In......................................................................................................................................... 53
Bolt-On....................................................................................................................................... 54

	 	

Residential Fuse Panel Inserts
Insert Interiors............................................................................................................................ 56
Trims........................................................................................................................................... 57
Data Information Form............................................................................................................... 58

	 	

Replacement Classic Circuit Breakers
Bolt-On Type BQL Single, Multi-Pole, Duplex™, & Quadplex™................................................. 59
Bolt-On Type BQL Ground Fault & Moulded Case Switches..................................................... 60
Bolt-On Type QBH Single, Multi-Pole, & Accessories................................................................ 61
Plug-In Type BJ Two & Three Pole............................................................................................. 62

	 	

Pressure Switches
Pressure Switches...................................................................................................................... 63

	 	

Catalogue Number Index
Catalogue Number Index............................................................................................................ 64

II	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Type CPM/CPL Plug-In Loadcentres

Product Description
Loadcentres feature factory
installed main lugs or main
breakers. The BR interiors are
manufactured of formed, plated
aluminum. Eaton also supplies
a full line of Eaton brand
BR, DNPL, GFCB and GFEP
type branch circuit breakers
and accessories for these
loadcentres.

Product Application
Designed for the protection and
distribution of single and multidwelling residential and light
commercial loads to 120/240
volts AC, such as lighting,
heating, appliance and small
motor branch circuits.
All Main Breaker Combination
Loadcentres are CSA listed
for use as service entrance
equipment.

Ratings

Single phase, 3 wire, 120/240
volts AC and 3 phase, 4 wire,
120/208 volts AC. Mains
through 400 amperes. Available
with up to 84 branch circuits.
Main breakers on 150 & 200
Amp panels are rated at 25,000
AIC.

Metal Enclosure
Specifications

All plug-in loadcentres are UL
listed to file E52977.

Enclosures are made of 16
gauge galvanized sheet steel.
The galvanized coating provides
corrosion protection and as such
does not require paint. All trims
used on BR Loadcentres are
chromate sealed and finished
with an electro-disposition
epoxy paint (ANSI-61) which
exceeds requirements for
outdoor and indoor applications.
A combination surface/flush
cover with integral door
is supplied with indoor
loadcentres rated from 100
through 400 amperes.
All plug-in loadcentres are CSA
listed to file LL98266.
CSA Certified to C22.2 No.29.

All loadcentres carry GOS
approvals of conformity.

Warranty
5 year limited.

Type CPM / CPL Loadcentre Features and Benefits
Six Mounting Holes
Three top, three bottom for ease of installation
in either vertical, horizontal or inverted
positions.

Adjustable Trim
For convenient flush leveling.

Dry Wall Markings on Enclosure
Notches on outside of box enclosure indicates
depth for dry wall.

200A Commercial Grade Main Breaker
Designed for straight-in wiring – horizontally
operated for top feed without modification.
100A models utilize a reverse fed branch circuit
breaker.

Single Keyhole Mounting
Just one keyhole at top and bottom for easier
mounting and leveling.
Single Piece, Formed, Plated Aluminum Bus Bar
Provides superior conductivity.

Neutral Bonding Strap
Pre-attached at factory to eliminate loose parts.

Maximum Wiring Space
For ease of wiring in compliance with CSA
requirements.

Contractor Friendly Knockouts
Improved knockout configurations include
tangential knockouts in top and bottom box
ends.

	

Twin Neutral Design
Reduces wireway congestion, provides for
easier wiring and load balancing. I-beam
design for improved durability.

Standard 14-3/8” Wide Enclosure

Steel Backpan
Provides positive, reliable breaker mounting.

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	



Type CPM Plug-In Loadcentres

Combination (Main Circuit Breaker) Single Phase Type 1

3 Wire 120/240VAC Combination Service Entrance Type 1 (Indoor)
Product Selection
Table 1. Main Circuit  Breaker Indoor Type 1 Loadcentres
Maximum
Ampere
Rating

Main
Breaker
Rating

Catalogue Number

Max. No. 1”
Spaces

Max.
No. 1/2”
Spaces

Dimensions (in)

Cover Style

Type of
Main
Breaker

H

W

D

Wire Size Range for
Main CU/AL

125 Amp

100 Amp

CPM112

12

24

Flush/Surface

BR ac

125 Amp

–

CPM112LMB

18-3/4

14-3/8

3-7/8

#4 - 1/0

12

24

Flush/Surface

BR h

18-3/4

14-3/8

3-7/8

#4 - 1/0

125 Amp

100 Amp

125 Amp

–

CPM116

16

32

Flush/Surface

BR

21

14-3/8

3-7/8

#4 - 1/0

CPM116LMB

16

32

Flush/Surface

BR h

21

14-3/8

3-7/8

#4 - 1/0

125 Amp
125 Amp

125 Amp

CPM116Z

20

40

Flush/Surface

BR

21

14-3/8

3-7/8

#4-2/0

100 Amp

CPM120

20

40

Flush/Surface

BR ac

27

14-3/8

3-7/8

#4 - 1/0

125 Amp

–

CPM120LMB

20

40

Flush/Surface

BR

h

27

14-3/8

3-7/8

#4 - 1/0

125 Amp

125 Amp

CPM120Z

20

40

Flush/Surface

BR

f

27

14-3/8

3-7/8

#4-2/0

125 Amp

100 Amp

CPM120H

20

40

Flush/Surface

BRH g

27

14-3/8

3-7/8

#4 - 1/0

125 Amp

100 Amp

CPM130

30

60

Flush/Surface

BR

29

14-3/8

3-7/8

#4 - 1/0

125 Amp

125 Amp

CPM130Z

30

60

Flush/Surface

BR f

29

14-3/8

3-7/8

#4-2/0

125 Amp

100 Amp

CPM130H

30

60

Flush/Surface

BRH

150 Amp

150 Amp

CPM1520

20

40

150 Amp

150 Amp

CPM1530

30

60

150 Amp

150 Amp

CPM1540

40

200 Amp

200 Amp

CPM216

16

200 Amp

200 Amp

CPM220

200 Amp

200 Amp

CPM230

200 Amp

200 Amp

400 Amp

400 Amp

CPM112
	
	
c
	
d
	
a
b

	

e

	

ac

f

ac

29

14-3/8

3-7/8

#4 - 1/0

Flush/Surface

BWH

b

29-1/8

14-3/8

3-7/8

#2-300MCM

Flush/Surface

BWH b

34-1/8

14-3/8

3-7/8

#2-300MCM

80

Flush/Surface

BWH

39

14-3/8

3-7/8

#2-300MCM

32

Flush/Surface

BWH b

29-1/8

14-3/8

3-7/8

#2-300MCM

20

40

Flush/Surface

BWH

b

29-1/8

14-3/8

3-7/8

#2-300MCM

30

60

Flush/Surface

BWH b

34-1/8

14-3/8

3-7/8

#2-300MCM

CPM240

40

80

Flush/Surface

BWH

39

14-3/8

3-7/8

#2-300MCM

CPM442

42

42

Flush/Surface

DK

66-1/2

16-1/8

6-5/16

(2)#2/0- 250MCM or
(1)#2/0-500MCM i

d

e

b

b

BR2040B200P	LOADCENTER
CPM1520
200	AMP	MAIN	BREAKER

BR2020B100P	LOADCENTER
CPM120
100	AMP	MAIN	BREAKER

Type BR-100 Amp 10kAIC Main Circuit Breaker is factory installed (BR2100).
Factory installed 25 kAIC Main Breaker.
High Interrupting BRH Breakers are available on page 13.
Restricted due to available neutrals, extra neutrals are available on page 11, which will expand
available circuitry to a maximum of 84 circuits.
DK Breaker is a 65 kAIC, factory-sealed Breaker.

g

	
	
h
	
i
	
f
g

BR4040B200P	LOADCENTER
CPM240
200	AMP	MAIN	BREAKER

BR2125 main breaker is factory installed.
BRH2100 – 22kA high interrupting main breaker is factory installed.
Main Breaker is not supplied.
3TA401K must be ordered separately for #2/0-500 MCM.

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Type CPM Plug-In Loadcentres

Combination (Main Circuit Breaker) Single Phase Type 3R

3 Wire 120/240VAC Combination Service Entrance Type 3Rc (Outdoor/Raintight)
Product Selection
Table 2. Main Circuit Breaker Outdoor/Raintight Type 3Rc Loadcentres
Maximum
Ampere
Rating

Main Breaker
Rating

Catalogue
Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Dimensions (in)

125 Amp

100 Amp

RCPM112 e

12

125 Amp

100 Amp

RCPM120 e

125 Amp

100 Amp

RCPM130

150 Amp

150 Amp

RCPM1530 e

200 Amp

200 Amp

200 Amp
200 Amp

Cover Style

Type of Main
Breaker

H

W

D

Wire Size Range
for Main CU/AL

24

Outdoor

BRad

18-1/2

14-3/8

5

#4 - 1/0

20

40

Outdoor

BRad

25

14-3/8

5

#4 - 1/0

30

60

Outdoor

BR

28-7/8

14-3/8

5

#4 - 1/0

30

60

Outdoor

BWHb

33-7/8

14-3/8

5

#2-300MCM

RCPM220

e

20

40

Outdoor

BWH

28-7/8

14-3/8

5

#2-300MCM

200 Amp

RCPM230

e

30

60

Outdoor

b

BWH

33-7/8

14-3/8

5

#2-300MCM

200 Amp

RCPM240 e

40

80

Outdoor

BWHb

38-3/4

14-3/8

5

#2-300MCM

e

ad

b

RCPM220

	
	
c
	
d
	
e
	
a
b

Type BR-100 Amp 10kAIC Main Circuit Breaker is factory installed (BR2100).
Factory installed 25 kAIC Main Breaker.
Outdoor Loadcentres accommodate Type DS Conduit Hubs. Hubs not included. See Page 11 for selection.
High interrupting BRH breakers are available on page 13.
All enclosures include a locking hasp as an integral part of the door latching mechanism.
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	



Type CPM Plug-In Loadcentres

Combination (Main Circuit Breaker) Three Phase Type 1

4 Wire 120/208VAC Combination Service Entrance Type 1 (Indoor)
Product Selection
Table 3. Main Circuit Breaker Indoor Type 1 Loadcentres
Maximum
Ampere
Rating

Main Breaker
Rating

Catalogue
Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Dimensions (in)

125 Amp

100 Amp

3CPM112

12

125 Amp

100 Amp

3CPM130

200 Amp

200 Amp

400 Amp

400 Amp

Cover Style

Type of Main
Breaker

H

W

D

Wire Size Range for
Main CU/AL

24

Flush/Surface

BR ab

21

14-3/8

3-3/4

#4 - 1/0

30

60

Flush/Surface

CC c

39

14-3/8

3-3/4

#4 - 4/0

3CPM230

30

60

Flush/Surface

CC

39

14-3/8

3-3/4

#1 - 250 MCM

3CPM442

42

42 d

Flush/Surface

DK e

66-1/2

16-1/8

6-5/16

(2) 2/0-250MCM
(1) 2/0-500MCM 

3CPM112

	
	
c
	
d
	
e
	

	
a
b

	

c

BR2020B100P	LOADCENTER
3CPM130
100	AMP	MAIN	BREAKER

3CPM230

Type BR-100 Amp 10kAIC Main Circuit Breaker is factory installed (BR3100).
High interrupting BRH breakers are available on page 13.
Factory installed 10 kAIC Main Breaker.
Extra Neutrals which will expand available circuitry to a maximum of 84 circuits are available on page 11.
DK Breaker is a 65 kAIC factory-sealed Main Breaker.
Circuit breaker lug kit 3TA401 must be ordered separately to accept #2/0 - 500MCM cabling.
Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Type CPM Plug-In Loadcentres

Combination (Main Circuit Breaker) Three Phase Type 3R

4 Wire 120/208VAC Combination Service Entrance Type 3R

de

(Outdoor/Raintight)

Product Selection
Table 4. Main Circuit Breaker Outdoor/Raintight Type 3R

de

Loadcentres

Maximum
Ampere Rating

Main Breaker
Rating

Catalogue
Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Cover Style

Type of Main
Breaker

100 Amp

100 Amp

R3CPM112 e

12

24

Outdoor

125 Amp

100 Amp

R3CPM130

e

30

60

200 Amp

200 Amp

R3CPM230 e

30

60

Dimensions (in)
H

W

D

Wire Size Range
for Main CU/AL

BRab

20-3/4

14-3/8

5

#4 - 1/0

Outdoor

CC

c

38-3/4

14-3/8

3-3/4

#4 - 4/0

Outdoor

CC c

38-3/4

14-3/8

3-3/4

#1-250MCM

R3CPM230

	
	
c
	
d
	
e
	
a
b

Type BR-100 Amp 10kAIC Main Circuit Breaker is factory installed (BR3100).
High interrupting BRH breakers are available on page 13.
Factory installed 10 kAIC Main Breaker.
Outdoor Loadcentres accommodate Type DS conduit hubs. Hubs not included. See Page 11 for selection.
All enclosures include a locking hasp as an integral part of the door latching mechanism.
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	



Type CPL Plug-In Loadcentres

Non-Combination (Main Lug Only) Single Phase Type 1

3 Wire 120/240VAC Non-Combination Type 1 (Indoor)
Product Selection
Table 5. Main Lug Only Indoor Type 1 Loadcentres
Dimensions (in)

Maximum
Ampere Rating

Catalogue Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for Main CU/AL

100 Amp

CCPL102

2

4

Surface

11-1/2

6-3/4

3-1/4

#14 - 1/0

125 Amp

CCPL104

4

8

Flush/Surface

13

11

3-1/2

#14 - 1/0

125 Amp

CCPL108

8

16

Flush/Surface

13

11

3-1/2

#14 - 1/0

125 Amp

CPL112

12

24

Flush/Surface

16-3/4

14-3/8

3-7/8

#14 - 1/0

125 Amp

CPL116

16

32

Flush/Surface

18-3/4

14-3/8

3-7/8

#14 - 1/0

125 Amp

CPL116W

16

32

Flush/Surface

18-3/4

14-3/8

3-7/8

#14 - 1/0

125 Amp

CPL120

20

40

Flush/Surface

21

14-3/8

3-7/8

#14 - 1/0

125 Amp

CPL120W

20

40

Flush/Surface

21

14-3/8

3-7/8

#14 - 1/0

125 Amp

CPL130

30

60

Flush/Surface

29-1/8

14-3/8

3-7/8

#14 - 1/0

125 Amp

CPL130W

30

60

Flush/Surface

29-1/8

14-3/8

3-7/8

#14 - 1/0

200 Amp

CPL220

20

40

Flush/Surface

27

14-3/8

3-7/8

#2-300MCM

200 Amp

CPL220W

20

40

Flush/Surface

27

14-3/8

3-7/8

#2-300MCM

200 Amp

CPL240

40

80

Flush/Surface

34-1/8

14-3/8

3-7/8

#2-300MCM

200 Amp

CPL240W

40

80

Flush/Surface

34-1/8

14-3/8

3-7/8

#2-300MCM

400 Amp

CPL442

42

42

Flush/Surface

54

16-1/8

6-5/16

(1) 250-750MCM
(2) 3/0-250MCM

b

b

b

b

CPL112

a

BR1224L125P	LOADCENTER
100	AMP	MAIN	LUG

	
	
c
	
a
b

	

c

CPL220

CPL120

Service equipment approved when used with 2 pole BR type breaker.
Loadcentre comes with a painted white trim & door
Extra Neutrals which will expand available circuitry to a maximum of 84 circuits are available on page 11.
Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Type CPL Plug-In Loadcentres

Non-Combination (Main Lug Only) Single Phase Type 3R

3 Wire 120/240VAC Non-Combination Service Entrance Type 3R

a

(Outdoor/Raintight)

Product Selection
Table 6. Main Lug Only Outdoor/Raintight Type 3R
Maximum
Ampere Rating

Catalogue Number

100 Amp

a

Loadcentres
Dimensions (in)

Max. No. 1” Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for
Main CU/AL

RCCPL102 c

2b

4

Outdoor

11-1/2

6-1/2

4

#14-2/0

125 Amp

RCCPL104

c

4

8

Outdoor

13

11

3-1/2

#14-2/0

125 Amp

RCCPL108 c

8

16

Outdoor

13

11

3-1/2

#14-2/0

125 Amp

RCPL112

c

12

24

Outdoor

16-1/2

14-3/8

5

#14-2/0

125 Amp

RCPL120

c

20

40

Outdoor

20-3/4

14-3/8

5

#14-2/0

125 Amp

RCPL130 c

30

60

Outdoor

28-7/8

14-3/8

5

#14-2/0

200 Amp

RCPL220

c

20

40

Outdoor

25

14-3/8

5

#2-300MCM

200 Amp

RCPL240 c

40

80

Outdoor

33-7/8

14-3/8

5

#1-250MCM

BR1224L200RFP	LOADCENTER
RCPL112
200	AMP	MAIN	LUG

RCPL220
CH24L125RP

125	amp
Main	Lug	Loadcenter
Outdoor

	
	

	
a
b

Outdoor Loadcentres accommodate Type DS conduit hubs. Hubs not included. See page 11 for selection.
Service equipment approved when used with 2 pole BR type breaker.
All enclosures include a locking hasp as an integral part of the door latching mechanism.
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	



Type CPL Plug-In Loadcentres

Non-Combination (Main Lug Only) Three Phase Type 1

4 Wire 120/208VAC Non-Combination Type 1 (Indoor)
Product Selection
Table 7. Main Lug Only Indoor Type 1 Loadcentres
Dimensions (in)

Maximum Ampere
Rating

Catalogue Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for
Main CU/AL

100Amp

3CCPL103

3a

6

Surface

14-1/4

6-1/2

3-1/4

#14-2/0

125 Amp

3CPL112

12

24

Flush/Surface

21

14-3/8

3-7/8

#14-2/0

125Amp

3CPL124

24

48

Flush/Surface

29

14-3/8

3-3/4

#14-2/0

125 Amp

3CPL130

30

60

Flush/Surface

34.12

14-3/8

3-3/4

#14-2/0

125 Amp

3CPL136

36

72

Flush/Surface

39

14-3/8

3-3/4

#14-2/0

200 Amp

3CPL218

18

36

Flush/Surface

27

14-3/8

3-7/8

#2-300MCM

200 Amp

3CPL224

24

48

Flush/Surface

34.12

14-3/8

3-7/8

#2-300MCM

200 Amp

3CPL230

30

60

Flush/Surface

34.12

14-3/8

3-3/4

#2-300MCM

200 Amp

3CPL242

42

84

Flush/Surface

39

14-3/8

3-7/8

#2-300MCM

400 Amp

3CPL442

42

42

Flush/Surface

54

16-3/8

6-5/16

(1) 250-750MCM
(2) 3/0-250MCM

BR1224L125P	LOADCENTER
3CPL112
100	AMP	MAIN	LUG

	
	

a
b

	

b

3CPL224

3CPL124

Suitable for use as service equipment when used with 3 pole BR type breaker.
Extra Neutrals which will expand available circuitry to a maximum of 84 circuits are available on page 11.
Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Type CPL Plug-In Loadcentres

Non-Combination (Main Lug Only) Three Phase Type 3R

4 Wire 120/208VAC Non-Combination Service Entrance Type 3R

a

(Outdoor/Raintight)

Product Selection
Table 8. Main Lug Only Outdoor/Raintight Type 3R
Maximum
Ampere Rating

Catalogue Number

100 Amp

a

Loadcentres
Dimensions (in)

Max. No. 1” Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for
Main CU/AL

R3CCPL103 d

3b

-

Outdoor

14-1/4

7

3-1/2

#14-2/0

125 Amp

R3CPL112

d

12

24

Outdoor

20-3/4

14-3/8

5

#14-2/0

125 Amp

R3CPL130 d

30

60

Outdoor

38-3/4

14-3/8

5

#14-2/0

125 Amp

R3CPL136

d

36

72

Outdoor

38-3/4

14-3/8

5

#14-2/0

200 Amp

R3CPL230

d

30

60

Outdoor

33-7/8

14-3/8

5

#2-300MCM

200 Amp

R3CPL242 d

42

42 c

Outdoor

38-3/4

14-3/8

5

#2-300MCM

BR1224L200RFP	LOADCENTER
R3CPL112
200	AMP	MAIN	LUG

	
	
c
	

	
a
b

R3CPL230

Outdoor Loadcentres accommodate Type DS conduit hubs. Hubs not included. See page 11 for selection.
Suitable for use as service equipment when used with 3 pole BR type breaker.
Extra Neutrals to expand available circuitry to a maximum of 84 circuits are available on page 11.
All enclosures include a locking hasp as an integral part of the door latching mechanism.
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	



Type CPL Plug-In Loadcentres
Non-Combination (Main Lug Only) 70A Single Phase

3 Wire 250VAC Maximum Non-Combination
♦ Service entrance approved when used with 2 pole BR or BRH breakers. b

Product Selection
Table 9. 70A Main Lug Only Polymeric and Metallic Loadcentres
Maximum
Ampere Rating (A)

Dimensions (in)
Enclosure Style

Material

70

Indoor Type 1a

Polymeric

70

Indoor/Outdoor Type 3R

70

Indoor Type 1 Flush Mount

70

Indoor Type 1 Surface Mount a

70

Indoor/Outdoor Type 3R

CPL072 Indoor

	
	

	

	
a
b

10	

a

a

a

Catalogue Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

H

W

D

Wire Size Range
for Main CU/AL
(AWG)

CPL072

2

4

8-5/8

5

3-1/4

#14 - 2

Polymeric

CPL072R



2

4

8-11/16

6-1/4

4-5/16

#14 - 2

Metallic

CPL072FGP

2

4

9-7/16

4-1/2

3

#14 - 2

Metallic

CPL072SGP

2

4

9-7/16

4-1/2

3

#14 - 2

Metallic

CPL072RGP

2

4

9-7/16

4-1/2

3

#14 - 2

CPL072R Outdoor



CPL072FGP Flush

CPL072SGP Surface CPL072RGP Outdoor

Service Entrance approved when used with 2 pole BR/BRH breakers.
BR and BRH 2 pole breakers can be found on page 13.
Uses DS*H1 style hubs found on page 11.
The circuit breaker protective cover incorporates a locking hasp.
Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Type CPM/CPL Plug-In Loadcentre Accessories

Accessories
Product Selection
Table 10. Plug-In Loadcentre Accessories
Description

Catalogue Number

Description

Catalogue Number

NSP42

Door lock for 4-8 circuit 125A (CPM/CPL)

CH9FL 

Circuit Identification Labels (e.g. Hot Water Heater) b

BP3110C

Door lock for 12-42 circuit 100-225A & 400A (CPM/CPL)

TDL 
ISGRD

Number Strips for CPL/CPM 42 Circuits

a

Replacement door

c

for CPM112

CPM112COV

Isolated ground kit

Replacement door

c

for CPM116

CPM116COV

Trim screw kit (CPM/CPL)

Replacement door c for CPM120

CPM120COV

3/4” Hub for 100-125A Type 3R Loadcentres e

CVRSCRW
DS075H1

3”x2-3/4”

Replacement door

d

for CPM130

CPM130COV

1” Hub for 100-125A Type 3R Loadcentres

DS100H1

3”x2-3/4”

Replacement door c for CPM216

CPM216COV

1-1/4” Hub for 100-125A Type 3R Loadcentres e

DS125H1

3”x2-3/4”

c

e

Replacement door

c

for CPM220

CPM220COV

1-1/2” Hub for 100-125A Type 3R Loadcentres

Replacement door

c

DS150H1

3”x2-3/4”

e

e

for CPM230

CPM230COV

2” Hub for 100-125A Type 3R Loadcentres

DS200H1

3”x2-3/4”

Replacement door c for CPM240

CPM240COV

2” Hub for 150 & 200A Type 3R Loadcentres

DS200H2

4-3/4”x4-5/8”

Replacement door

for CPL112

CPL112COV

2-1/2” Hub for 150 & 200A Type 3R Loadcentres

DS250H2

4-3/4”x4-5/8”

Replacement door c for CPL116

CPL116COV

3” Hub for 150 & 200A Type 3R Loadcentres

DS300H2

4-3/4”x4-5/8”

Replacement door

c

for CPL120

CPL120COV

3/4” Hub for R3CCPL103 Loadcentres

RH75P

2-1/8”x3-1/4”

Replacement door c for CPL130

CPL130COV

1” Hub for R3CCPL103 Loadcentres

RH100P

2-1/8”x3-1/4”
2-1/8”x3-1/4”

c

Replacement door

c

for CPL220

CPL220COV

1-1/4” Hub for R3CCPL103 Loadcentres

RH125P

Replacement door

c

for CPL240

BRFP

CPL240COV

1” Filler plate kit

Replacement door c for 3CPM112

3CPM112COV

Sub-feed kit for 125A Loadcentres #8-2/0 g

Replacement door

f

BRSF125

for 3CPM130

3CPM130COV

Sub-feed kit for 150A 3 phase Loadcentres #8-2/0

Replacement door c for 3CPM230

3CPM230COV

Sub-feed kit for 225A Loadcentres #2-300MCM g

c

3BRSF150

g

Replacement door

c

for 3CPL112

3CPL112COV

Sub-feed kit for 225A 3 phase Loadcentres #2-300MCM

Replacement door

c

BRS225
g

3BRS225

for 3CPL124

3CPL124COV

Sub-feed kit for 400A Loadcentres #8-300MCM

Replacement door c for 3CPL130

3CPL130COV

Sub-feed kit for 400A 3 phase Loadcentres g

3BRS400

Replacement door

NL20

for 3CPL136

3CPL136COV

Neutral/Ground lug kit for 2/0

Replacement door c for 3CPL218

3CPL218COV

Neutral/Ground lug kit for 3/0 h

c

g

h

BRS400

NL30

Replacement door

c

for 3CPL224

3CPL224COV

Neutral/Ground lug kit for 300MCM (Maximum)

Replacement door

c

for 3CPL230

3CPL230COV

Neutral kit for 400A Combination Loadcentres

Replacement door c for 3CPL242

3CPL242COV

Neutral kit for 400A Non-combination Loadcentres j

CPL400KIT

Grey plastic replacement door latch

52-3125-5

	

a

b	
c	

	
	
f
	
g
	
h
	
d
e

i	

	
	

j


h

i

NL300
CPM400KIT

25 Per package. Catalogue number represents one package.
50 Per package. Catalogue number represents one package.
Includes trim, door, and deadfront..
100 Per package. Catalogue number represents one package.
Except R3CCPL103.
Kit includes 25 pieces.
Line/Load terminals supplied only. Neutral conductor must be purchased separately. See above listed kits.
Neutral bolts to main neutral bar i.e. remove screw & install lug kit.
Kit includes 2 Neutral bars.
Kit includes 1 Neutral bar.
Comes with a set of keys.
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

11

Plug-In Circuit Breakers for CPM/CPL
Type BR, DNPL, GFCB, GFEP, & GFXB

BR Circuit Breakers

Eaton Type BR plug-in breakers in the
standard 1-inch per pole moulded case
and can be used as main and/or branch
disconnect devices. All are CSA and UL
listed. Typical ampacity range for BR
breakers is 15 through 125 amperes a.

FIRE-GUARD™ Arc
Fault Circuit Interrupter
(AFCI)
The FIRE-GUARD Arc Fault Circuit
Interrupter (AFCI) is a residential circuit
breaker with an integrated processor
which recognizes the unique current
and/or voltage signatures associated
with arcing faults, and acts to interrupt
the circuit to reduce the likelihood of
an electrical fire. With the Eaton FireGuard AFCI, protection from arcing
faults is combined with conventional
thermal and magnetic overloads as
found in standard residential circuit
breakers protecting wiring from
excessive heat or damage due to

overloading or short circuits. Fire-Guard
AFCI can also be equipped with 5 mA
ground fault protection to protect from
personal shock hazards. Now, there is a
residential circuit breaker that provides
protection from arcing faults, conductor
damage due to thermal overloads and
short circuits, as well as 5 mA ground
fault protection in one integrated
design.

branch circuits. Type GFCB breakers
are also available in 10mA and 30mA
equipment protectors. 10mA GFCB are
required for submersible pump, sump
pump and well applications b. 30mA
breakers are for equipment requiring a
higher interrupting value such as heat
tracing.

All plug-in breakers are approved for
HACR applications a.
All ratings are CSA & UL listed.
CSA certified to C22.2 No. 5, file
LR3300.
All loadcentre breakers are GOS listed
for conformity.

DNPL Twin Circuit
Breakers

GFCB® People
Protection Breakers

DNPL plug-in breakers have the same
construction as Eaton Type BR 1-inch
per pole devices except that two one
pole circuits are provided in a
1-inch space a. CSA listed interrupting
rating is 10,000 AIC. All ratings are CSA
and UL listed.

Eaton Type GFCB (ground fault circuit
breaker) combines state-of-the-art
electronic technology with a circuit
breaker mechanism in a compact 1inch per pole moulded case. The GFCB
automatically senses hot wire-to-ground
faults in a 4 to 6 milliampere range
and shuts off the power thus providing
an extra margin of safety beyond
that of conventional circuit breakers.
GFCB applications include bathrooms,
basement outlets, swimming pools,
outdoor branch circuits and kitchen

DNPL Quad Circuit
Breakers

QuadplexTM construction of Eaton Type
DNPL plug-in breakers provides various
combinations of two pole and single
pole devices in a 2-inch moulded case.

Handle position On, Off, and Tripped
Indication

Exclusive steel frame calibration provides
greater calibration integrity than with screw
adjustment.
Four rivet construction enhances strength and
structural integrity of breaker case.

One-piece moulded case construction.
Hardened cradle for positive action under
fault conditions.

Heavy duty multi-strand flexible copper shunt
provides load terminal torque isolation.

Heavy duty mechanism spring for reliable
operation.

CSA approved terminal assembly for use with
copper or aluminum wire, screw is “backed
out” for faster insertion of wires.

Non-abrasive integrally moulded pivot for
quick mechanism response.

Magnetic assembly for reliable short circuit
protection.

One-piece moving contact arm for quick
on/off response.

Large gas port for venting short circuit gases
safely into loadcentre gutter.

Heavy duty line terminal and spring clip
for quick loadcentre installation and cool
operation.

Calibrated one-piece bimetal for reliable
thermal trip function.

Silver tungsten alloy contacts.
Unique one-piece heavy duty DE-ION® arc
extinguisher for quick arc interruption.

Robertson/slot load side screw.

Type BR

1”

a
b

Type DNPL
Duplex

1”

One pole 15 and 20 ampere units are switching duty (SWD) rated.
Submersible pump installations require ground fault protection to the maximum sensitivity level of 10 milliampere. These breakers meet Canadian electrical code CEC 26-956.

12	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Plug-In Circuit Breakers for CPM/CPL
Type BR Single and Multi-Pole

Type BR

cd

♦ 10,000 / 22,000 Amperes Interrupting Capacity at 120VAC, 120/240VAC, and 240VAC
♦ 2 and 3 pole versions feature a common trip

Product Selection
Table 11. Single and Multi-Pole Plug-In Circuit Breakers
1-Pole 120/240VAC

1-Pole 120/240VAC

2-Pole 120/240VAC

2-Pole 120/240VAC

3-Pole 120/240VAC

3-Pole 120/240VAC

10 per Shelf Carton

10 per Shelf Carton

5 per Shelf Carton

5 per Shelf Carton

5 per Shelf Carton

5 per Shelf Carton

10kAIC

22kAIC

10kAIC

22kAIC

10kAIC

22kAIC

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

ab

Ampere Rating

Wire Size Range
(Cu/AL 60ºC or 75ºC)

15

#14 - 4

BR115

BRH115

BR215

BRH215

BR315

BRH315

20

#14 - 4

BR120 a b

BRH120

BR220

BRH220

BR320

BRH320

25

#14 - 4

BR125

a

BRH125

BR225

BRH225

BR325

BRH325

30

#14 - 4

BR130

a

BRH130

BR230

BRH230

BR330

BRH330

35

#14 - 4

BR135 a

BRH135

BR235

BRH235

BR335

BRH335

40

#14 - 4

BR140

BRH140

BR240

BRH240

BR340

BRH340

45

#14 - 4

—

BRH145

BR245

BRH245

BR345

BRH345

50

#14 - 4

BR150

BRH150

BR250

BRH250

BR350

BRH350

60

#4 - 1/0

—

BRH160

BR260

BRH260

BR360

BRH360

70

#4 - 1/0

—

BRH170

BR270

BRH270

BR370

BRH370

80

#4 - 1/0

—

—

BR280

BRH280

BR380

BRH380

90

#4 - 1/0

—

—

BR290

BRH290

BR390

BRH390

100

#4 - 1/0

—

—

BR2100

BRH2100

BR3100

BRH3100

110

#4 - 1/0

—

—

—

—

—

—

125

#4 - 2/0

—

—

BR2125

—



—

150



—

—

175



—

—

200



—

— Circuit Breaker Product Selection—



a

a



Loadcenters & Circuit—Breakers
— Circuit Breakers
Type BR Loadcenters &

Requires One 1-Inch (25.4mm) Space

Plug-on Circuit Breakers, Types BR
3,000/ ,000 Interrupting Capacity
120/240-220/3 0-240/415 Volts AC

BR120
BR120





—





—





—

Requires Two 1-Inch (25.4mm) Spaces

Requires Three 1-Inch (25.4mm) Spaces

BR215
BR215

BR320
BR320

Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240, 10,000, 22,000
Ampere
Rating

Wire Size
1-Pole 120/240 Vac
2-Pole 120/240 Vac
Range
Requires One 1-Inch (25.4 mm) Space
Common Trip
Cu/Al
Requires Two 1-Inch (25.4 mm) Spaces
Available with high magnetic
for10switching
large
tungsten
lamp
loads.
Add
suffix
H
to
catalogue
number (e.g. BR115H).
60°C setting
or
per Shelf Carton
5 per Shelf Carton
75°C
Switching duty rated.
10 kAIC
10 kAIC
22 kAIC
22 kAIC

	
	
c
	 All Type BR 1, 2, and 3-pole circuit breakers carry listing for HACR application..
Catalog
Catalog
Catalog
Catalog
d
	 Breaker shunt trips are available but only
in 120VAC format. AdditionNumber
of a shunt trip adds a 1” space
width. For circuit breakers requiring
Number
Number
Numbera shunt trip add an ST suffix to the end of the catalogue number
(e.g. BR115ST).
—
—
BR210
10
#14 – 4
BR110

	 For subfeed
loadcentres
150, 175, or 200A subfeed circuit
breaker a Type BJ circuit breaker
can be used. Refer to page 62 for product space requirements and
�� requiring a 125,BRH115
BRH215
15 applications in 200 or 400ABR115
BR215
selection.
BR120 ��
BR220
BRH120
BRH220
20
a
b

	

25
30

35
40
45

BR125
BR225
BRH125
BRH225
BR130 & light commercial
BRH130 distributionBR230
BRH230
residential
products  PG.31.02.P.K
– September 2011 www.eatoncanada.ca	

#14 – 4

BR135
BR140
—

BRH135
BRH140
BRH145

BR235
BR240
BR245

BRH235
BRH240
BRH245

13

Plug-In Circuit Breakers for CPM/CPL

Type DNPL Duplex™, Independent Quadplex™, & Circuit Breaker Packs

Type DNPL

ab

♦ 10,000 Amperes Interrupting Capacity at 120VAC, 120/240VAC, and 240VAC

Product Selection
Table 12. Duplex™ and Independent Trip Quadplex™ Plug-In Circuit Breakers
Duplex™

Quadplex™ Independent Trip

Quadplex™ Independent Trip

Two Single Pole Circuits

Two Single Pole Circuits and One Double Pole Circuit

Two Double Pole Circuits

10 per Shelf Carton

5 per Shelf Carton

5 per Shelf Carton

120VAC

120VAC

120/240VAC

120VAC

120/240VAC

Ampere Rating

Ampere Rating

Ampere Rating

Catalogue Number

Outer Left
(1 Pole)

Centre
(2 Poles)

Outer Right
(1 Pole)

Catalogue Number

Outer Left & Right
(2 Poles)

Centre
(2 Poles)

Catalogue Number

Wire Size Range
(Cu/AL 60ºC or 75ºC)

15-15

DNPL1515

15

15

15

DNPL151515

15

15

DNPL215215

#14 - 4 AWG

15-20

DNPL1520

15

20

15

DNPL152015

15

20

DNPL215220

#14 - 4 AWG

15-30

DNPL1530

15

25

15

DNPL152515

15

30

DNPL215230

#14 - 4 AWG

20-20

DNPL2020

15

30

15

DNPL153015

15

40

DNPL215240

#14 - 4 AWG

—

—

15

40

15

DNPL154015

20

20

DNPL220220

#14 - 4 AWG

—

—

15

50

15

DNPL155015

20

30

DNPL220230

#14 - 4 AWG

Requires One 1-Inch (25.4mm) Space

Independant Trip
Requires Two 1-Inch (25.4mm) Spaces

Independent Trip
Requires Two 1-Inch (25.4mm) Spaces

Type BP (Circuit Breaker Packs)
♦ Single carton packaged
♦ Represents common household combinations

Product Selection

DNPL2020

DNPL155015

DNPL230230

Table 13. Plug-in Circuit Breaker House Paks

a
b

Contents

Catalogue
Number

Contents

Catalogue
Number

(3) DNPL151515, (1) DNPL153015, (1) DNPL154015

BP2

(16) BR115, (3) BR215, (1) BR230, (1) BR240

BP24

(10) BR115, (3) BR215, (1) BR230, (1) BR240

BP4

(14) BR115, (2) BR120, (1) BR230, (1) BR240

BP27

(2) DNPL1515, (1) DNPL215215, (1) DNPL152015, (1) DNPL153015, (1)
DNPL154015

BP16

5 of DNPL1515, 1 of DNPL2020, 1 of DNPL153015, 1 of DNPL154015

BP31

(6) DNPL1515, (2) DNPL151515, (1) DNPL153015, (1) DNPL154015

BP18

(1) BR120, (4) DNPL1515, (1) DNPL151515, (1) DNPL153015, (1) DNPL154015

BP32

(1) DNPL1515, (3) DNPL151515, (2) DNPL153015, (1) DNPL154015

BP21

(10) BR115, (2) BR120, (1) BR215, (1) BR220, (1) BR230, (1) BR240

BP41

(3) DNPL1515, (3) DNPL151515, (1) DNPL153015, (1) DNPL154015

BP23

(3) DNPL1515, (1) DNPL153015, (1) DNPL154015, (1) DNPL2020, (1) DNPL1520 BP54

All Type DNPL Duplex™ and Quadplex™ circuit breakers carry listing for HACR applications.
All 15 and 20 ampere single poles are switch-duty rated.

14	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Plug-In Circuit Breakers for CPM/CPL
Type BR Arc Fault Circuit Interrupter

Type BR Arc Fault Circuit Interrupter Circuit Breakers
♦ 10,000 Amperes Interrupting Capacity at 120VAC, 120/240VAC, and 240VAC

Product Description

An arc fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and
by functioning to de-energize the circuit when the arc fault is detected. As of January 1, 2002, the Canadian Electrical Code now requires that all branch
circuits that supply 125 Volt, single phase, 15 and 20 Ampere receptacle outlets installed in dwelling unit bedrooms shall be protected by an Arc Fault
Circuit Interrupter(s).
Figure 1. 1-Pole Single 120V Load
Application Sourced by 120/240VAC

Product Selection
Table 14. Single and Two Pole Plug-In FIRE-GUARD™ AFCI Circuit Breakers
1-Pole 120/240VAC

2-Pole a b 120/240VAC

10 per Shelf Carton

5 per Shelf Carton

10kAIC

10kAIC

Ampere
Rating

Configuration

Catalogue Number

Catalogue Number

Wire Size Range
(Cu/AL 60ºC or 75ºC

15

Standard

BR115AF c

—

#14 - 4 AWG

15

Compact

BRC115AF

—

15

Common Trip

—

BRL215AF

15

Independent Trip

—

BRL215AFIT

20

Standard

BR120AF c

—

#14 - 4 AWG

20

Compact

BRC120AF

—

#14 - 4 AWG

20

Common Trip

—

BRL220AF 

20

Independent Trip

—

BRL220AFIT

Requires One 1-Inch (25.4mm)
Space

Requires Two 1-Inch (25.4mm)
Spaces

#14 - 4 AWG
#14 - 4 AWG




#14 - 4 AWG

Figure 2. 2-Pole Shared Neutral with
Multi-Duplex Receptacle Application

#14 - 4 AWG


#14 - 4 AWG

Figure 3.  2-Pole 240V Load
Application Sourced by 120/240VAC

Type BR 1- and 2-Pole
Type BR
1 and
2 Pole Breakers
AFCI Circuit Breakers
AFCI
Circuit

Figure 4. 2-Pole Shared Neutral with
Duplex Receptacle Application

Common trip refers to 2-pole 240 volt load application sourced by 120/240 Vac (see Figure 3).
Independent trip refers to 2-pole multi-wire, home run or shared neutral circuits (see Figure 2 and Figure 4).
c
Will not fit into CPM112, CPL112, CPL116, CPL120, CPL220, CPL240, 3CPM112, 3CPL218, 3CPL224 or 3CPL230 prior to November 2004.

Long style circuit breakers. Please speak to your local Eaton sales rep for proper application.

a

b

	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

15

10,000/22,000 Amperes Interrupting Capacity

120 Circuit
Vac and 120/240
Vac
Plug-In
Breakers
for CPM/CPL
Type GFCB Ground Fault Circuit Breakers — 5 Milliampere —

Loadcenters
&
Circuit
Breakers
Types GFCB
&
GFEP
Ground
1-Inch
(25.4 mm)
per PoleFault
120 Vac or 120/240 Vac, 10,000 AIC
Type BR Loadcenters
&Size
Circuit
Breakers
Ampere
Wire
Range
1-Pole
Rating

Cu/Al 60°C or 75°C

120 Vac
Requires One
1-Inch
(25.4 mm)
Space

2-Pole
120/240 Vac
Common Trip
Requires Two
1-Inch
(25.4 mm)
Spaces

1 per Shelf Carton

1 per Shelf Carton

Type GFCB and GFEP Ground Fault Circuit Breakers
10,000/22,000 Amperes Interrupting Capacity

♦ 10,000 / 22,000
Amperes
Capacity at 120VAC and 120/240VAC
10,000 AIC
120 Vac
and Interrupting
120/240 Vac
♦ 5mA “People
Protection”
or 30mA
Equipment
Protectors
Type
GFCB Ground
Fault Circuit
Breakers
— 5 MilliampereCatalog
—
Number �
1-Inch (25.4
mm) common
per Pole 120
♦ Two pole version
features
trip.Vac or 120/240 Vac, 10,000 AIC

�
�

20
25
30
40
50
60

GFCB115
GFCB215
2-Pole
GFCB120
GFCB220
120/240 Vac
GFCB125
GFCB225
Common Trip
GFCB130
GFCB230
Type
GFCB
2-Pole
Requires Two
Type
GFCB
1-Pole
GFCB
2-Pole
GFCB
1-Pole
GroundGFCB140
Fault
Circuit Breakers GFCB240
1-Inch
�
—
GFCB250
(25.4 mm)
1-Pole 120VAC
1-Pole 120VAC
2-Pole 120/240VAC
2-Pole 120/240VAC
Available with bell alarm or auxiliarySpaces
switch. See circuit breaker accessories on Page 3-62.

per Shelf
Carton
For1 use
with copper
1 perwire
Shelfonly.
Carton

15
20
25
30
40
50
�
�

#14 – 4

#14 - 4
#14 - 4
#14 - 4

Ampere
Wire Size Range
GFCB115
Rating
Cu/Al 60°C
or 75°Ca
GFCB115
GFCB120
GFCB125
GFCB120 a
GFCB130
GFCB140
GFCB125 a
—

#14 - 4

GFCB140

Type GFCBH Ground Fault Breakers — 5 Milliampere — Catalog
4 120 Vac or 120/240 Vac,
— 22,000 AICNumber
1-Inch (25.4 mm)#14
per-Pole
Ampere
Rating

Ampere Rating 15

25
30
40
50

2-Pole
120/240 Vac
Common Trip
Requires Two
1-Inch
(25.4 mm)
Spaces

1 per Shelf Carton

10kAIC

22kAIC

Catalogue Number

Catalogue Number

GFCB215

GFCBH215

GFCB220 Type GFCB 2-Pole GFCBH220
GFCB225
GFCBH225

1-Pole 120VAC

1 per Shelf Carton
1-Pole
22,000 AIC 1 per Shelf Carton
120 Vac
Requires
One
Catalog
10kAIC
1-InchNumber
Space

GFCB250

Catalogue Number
GFCBH215
1 per Shelf
Carton
1 per Shelf Carton

#14 - 4

Catalog
GFCBH230
Number

GFCBH120
#14
-4
GFCBH125
—

GFCBH220
10,000GFCBH225
AIC

—
—

b

�

#14
-4
1-Pole

10,000 AIC
Catalog

Number
Ground Fault Application Note

1 per Shelf Carton
10kAIC
Catalogue Number

10,000 AIC

GFEP215

GFEP120

Catalog
Number

GFEP220

GFEP125

GFEP215
GFEP220
GFEP225
GFEP230
GFEP240
GFEP250 �

GFEP225

GFEP130

120 Vac
#14
- 4 One
Requires
1-Inch Space

1 per Shelf Carton

2-Pole 120/240VAC

GFEP115

GFEP125
2-Pole
GFEP130
120/240 Vac
—
—
Common Trip
—
Requires Two
#14 - 4
—
1-Inch Spaces
For use with copper wire only.

Wire Size Range 25
30
Cu/Al 60°C or 75°C
40
50

2-Pole
120/240 Vac
Common Trip
Requires Two
1-Inch Spaces

(AWG)
GFCBH115

Type GFEP Ground Fault Equipment
Protectors (30 Milliampere),
15 #14 - 4 #14 – 4
GFEP115
1-Inch (25.4 mm) per Pole 120
20Vac or 120/240 Vac, 10,000 AICGFEP120
Ampere
Rating

—

Catalog
Number

GFCBH230

GFCB240

GFCBH115
GFCBH215
1-Pole #14 – 4 —
2-Pole
—
GFCB260
—
GFCBH120
GFCBH220
120 Vac
120/240 Vac
GFCBH125
GFCBH225
Requires One Requires One 1-Inch (25.4mm)
CommonSpace
Trip
Requires Two 1-Inch (25.4mm) Spaces
—
GFCBH230
1-Inch
Requires Two
(25.4 mm)
1-Inch
Two
Plug-In
Circuit
Breaker Equipment Protectors
Space
(25.4 mm)
TypePole
GFEP Ground
FaultGround
EquipmentFault
Protectors
(30 Milliampere),
Spaces Vac, 10,000 AIC
1-Inch (25.4 mm) per Pole 120 Vac or 120/240

#14 – 4

20
25
30

—

15
Wire #14
Size-Range
6
20
Cu/Al 60°C or 75°C
25
30

1 per Shelf Carton
Ampere
Wire Size Range
22,000 AIC
Rating
Cu/Al 60°C or 75°C
Catalog
Wire
Size Range
Number
Cu/Al
60°C or 75°C

20

1-Pole
GFCB215
120 Vac
GFCBH115
GFCB220
Requires
One
1-Inch GFCB225 GFCBH120
GFCB230
(25.4 mm)
Space GFCB240 GFCBH125
GFCB250 �

1 per Shelf Carton

a breaker accessories on Page 3-62.
Available with#14
bell- alarm
or auxiliary switch. GFCB130
See circuit
4
GFCB230
1 per Shelf Carton GFCBH130
1 per Shelf Carton
For use with copper wire only.
22,000 AIC
22,000 AIC
a

Table 16. 30mA Single and

15

1 per Shelf Carton
1 per Shelf Carton

10,000 AIC
Wire Size Range 10,000 AIC
22kAIC—
Type GFCBH Ground10kAIC
Fault Breakers —Catalog
5 Milliampere
Cu/Al 60°C or 75°CCatalog
1-Inch
(25.4
mm)
per
Pole
120
Vac
or
120/240
Vac, 22,000 AIC
�
Number
Catalogue Number Number Catalogue Number
(AWG)

Ampere Rating

15

10,000 AIC
Catalog
Number

Wire Size Range 15 1-Pole #14 – 4
20 120 Vac
Cu/Al 60°C or 75°C
25 Requires One
30 1-Inch
Single and Two40Pole
Plug-In
(25.4 mm)
50 Space

Ampere
Rating

Product Selection
Table 15. 5mA

Type GFCB 1-Pole

1 per Shelf Carton
Requires One 1-Inch (25.4mm) Space
10,000 AIC

GFEP230
GFEP240
GFEP250 b
Requires Two 1-Inch (25.4mm) Spaces

Catalog
Number

15
GFEP115
– 4 breakers (GFCBs)
GFEP215
Single-pole ground
fault #14
circuit
are designed for use in 2-wire,
20
GFEP120
GFEP220
120VAC circuits.
configuration.
25 Figure 5 shows a typical wiring
GFEP125
GFEP225
30
GFEP130
GFEP230
Two-pole GFCBs
are designed for use in 3-wire,
120/240VAC circuits, 120VAC
multi40
—
GFEP240
� a
50
— 2-wire, 240VAC circuits obtained
GFEP250
wire circuits employing
common, neutral and
from
� For use with copper wire only.
120/240VAC source.
Figures 6 and 7 illustrate typical wiring configurations for 120/240VAC multi-wire
circuits.
Figure 8 depicts a 240VAC, 2-wire circuit. Note the “panel neutral” conductor connects
to the neutral bar, even though the neutral is not included in the load circuit. This
connection is necessary to supply a 120VAC power source to the ground fault sensing
circuit.
The figures are shown with a 120/240VAC, single-phase, 3-wire power source, but
are also applicable to a 120/208VAC, 3-phase, 4-wire power supply. For all figures the
electrical operation of the GFCB is not affected by the equipment ground.

Auxiliary switches and bell alarms are available under special order. Add suffix W1 for alarm switch
and W2 for auxiliary switch.
b
For use with copper wire only.

Figure 5. 1-Pole

Figure 6. 2-Pole

Figure 7. 2-Pole

Figure 8. 2-Pole

a

16	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Plug-In Circuit Breakers for CPM/CPL

Type BR Internationally Rated
Plug-on Circuit Breakers, Types BR
3,000/ ,000 Interrupting Capacity
120/240-220/3 0-240/415 Volts AC

Type BR Internationally Rated Circuit Breakers

Loadcenters & Circuit B
Type BR Loadcenters &

♦ 3,000 / 6,000 Amperes Interrupting Capacity at 240/415VAC
♦ Two and three pole versions feature common trip

Circuit Breaker Product Selection

Product Selection
Table 17. Single and Two Pole Plug-In Internationally Rated Circuit Breakers a b
1-Pole 240/415VAC
10 per Shelf Carton

Plug-on Circuit Breakers, Types BR
240/415VAC
2-Pole 240/415VAC
3,000/ ,0002-Pole
Interrupting
Capacity
BR120
BR120E
10 per Shelf 120/240-220/3
Carton
5 per Shelf
Carton
per Shelf Carton
0-240/415 Volts 5AC
Type BR Breakers, 1-Inch (25.4 mm) per Pol
1-Pole 240/415VAC

3kAIC

6kAIC

3kAIC

Ampere Rating

Wire Size Range
Cu/Al 60°C or 75°C
(AWG)

Catalogue Number

Catalogue Number

Catalogue Number

Ampere
Rating
Catalogue Number

15

#14 - 4

BR115E

BRH115E

BR215E

BRH215E

20

#14 - 4

BR120E

BRH120E

BR220E

BRH220E

25

#14 - 4

BR125E

BRH125E

BR225E

BRH225E

30

#14 - 4

BR130E

BRH130E

BR230E

BRH230E

35

#14 - 4

BR135E

BRH135E

BR235E

BRH235E

40

#14 - 4

BR140E

BRH140E

45

#14 - 4

—

BR240E
BRH240E
Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240, 10,000, 22,000
35
#14 – 4
BRH145E Ampere
BR245E
BRH245E
Wire Size
1-Pole 120/240
Vac

50

#14 - 4

BR150E

BRH150E

60

#4 - 1/0

—

BRH160E

70

#4 - 1/0

—

BRH170E

80

#4 - 1/0

—

—

90

#4 - 1/0

—

—

100

#4 - 1/0

—

—

BR120

Rating

60
70
80
3kAIC
90
Catalogue Number 100
110

#14 - 4
#14 - 4

BR320E

25

#14 - 4

BR325E

30
35
40

Rating

#14 - 4
#14 - 4

50

#14 - 4

60

#4 - 1/0

70

10
#4 - 1/0
15
20
#4 - 1/0
25
30
#4 - 1/0

90
100

10 per Shelf Carton
10 kAIC

10 per Shelf BRH260E
Carton

BRH250E

BR110
BR115 ��
BR120 ��
BR215
BR215E
BR125
BR130

#14 – 4

50

5 per
Shelf Carton
BR150
kAIC
#4 – 1/0 10 BR160
70
BR170
Catalog
Catalog
80
—
Number
Number
90
—
— 100
BR210
—
BRH115
BR215
110
—
BR220
BRH120
125
#4 – 2/0
—
BR225
BRH125
—
BR230
BRH130
� One pole, 1-inch (25.4 mm) per pole circui
BRH135
BR235
lamp loads. Add suffix H to catalog numb
BR240
BRH140
� Switching duty rated.
BR245
BRH145
55
22 kAIC
60

10 kAIC

BR135
2-Pole
120/240 Vac
BR140
Common
Trip
—
Requires
BR150 Two 1-Inch (

#14 – 3

125
�
�

BR135
BR140
—
BR150

#14
– 3 240-415VAC
BR150
3-Pole
#4 – 1/0
BR160
5 per Shelf Carton
BR170
—
6kAIC
—
—
Catalogue Number
—

BRH315E
#4
– 2/0
—
—
BRH320E

BR250
BRH150
Notes: All Type BR 1-, 2-,
and 3-pole circu
BRH155
BR255
For circuit breakers with
a shunt trip, add

BRH160
BRH170
—
—
—
—

BR260
BR270
BR280
BR290
BR2100
BR2110

—
—

BR2125

One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting fo
lamp loads. Add
suffix H to catalog number.
BRH325E
BR215
BR320
BR320E
Switching duty rated.

#14 - 4
BR330E
BRH330E
Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240,Notes:
10,000,All
22,000
Type BR 1-, 2-, and 3-pole circuit breakers carry listing for HACR application.
For circuit breakers
with
a shunt
trip,
#14 - 4
BR335E
BRH335E
Ampere
Wire Size
1-Pole 120/240
Vac
2-Pole
120/240
Vacadd ST suffix.

45

80

BR315E

BR120

60°C or
BR260E
75°C

ab

5 per Shelf Carton

20

Range

#14 – 4

55

3-Pole 240-415VAC

15

10
15
20
25
30

10
#14 – 4
BR110
BR290E
BRH290E
��
15Circuit Breaker Product
BR115
Selection
BR120 �� BRH2100E
20
BR2100E
BR125
25
Requires Two 1-Inch
BR130(25.4mm) Spaces
30

Requires One 1-Inch (25.4mm) Space

Ampere Rating

1-Pole 120/240 Vac
Requires One 1-Inc

Catalog
Number

40
Requires One 1-Inch (25.4 mm)
45Space

BR250E
Cu/Al

Wire Size
Range
Cu/Al
60°C or
75°C

BR270E
BRH270E
Catalog
Loadcenters
&
Circuit
Breakers
Number
BR280E
BRH280E
Type BR Loadcenters & Circuit Breakers

Plug-on Circuit Breakers, Types BR
35
40
3,000/ ,000 Interrupting Capacity
45
120/240-220/3
0-240/415
Volts
AC
Table 18. Three Pole Plug-In Internationally Rated Circuit Breakers
50

Wire Size Range
Cu/Al 60°C or 75°C
(AWG)

6kAIC

Range
Cu/Al
60°C or
75°C

Requires One 1-Inch (25.4 mm) Space

BR340E

10 per Shelf
Carton
BR345E
10 kAIC

Catalog
Number
#14 – 4

35
#4 - 1/0
40
45
50

#14 – 4

55

#14 – 3

BR350E
BR360E

BR110
BR370E
BR115 ��
BR120 �� BR380E
BR125
BR130
BR390E
BR135
BR140
—
BR150

BR150

22 kAIC
Catalog
Number
—
BRH115
BRH120
BRH125
BRH130

Common Trip

BRH340E
Requires Two 1-Inch (25.4 mm) Spaces
5 per Shelf Carton
BRH345E
10 kAIC

BRH350E
Catalog

Number
BRH360E
BR210
BRH370E
BR215
BR220
BRH380E

BR225

BR230
BRH390E

BRH135
BR235
BRH3100E
BR240
BRH140
BR245
BRH145
Requires Three 1-Inch
(25.4mm) Spaces
BR250
BRH150

BR3100E

BRH155

BR255

22 kAIC
Catalog
Number
—
BRH215
BRH220
BRH225
BRH230
BRH235
BRH240
BRH245
BRH250
BRH255

60
#4 – 1/0
BR160
BRH160
BR260
BRH260
a
70
BR170
BRH170
BR270
BRH270
Built to British Standard BS3871.
80
—
—
BR280
BRH280
b
Non-stocked item requiring special order.
Speak
to
your
local
Eaton
sales
rep
for
lead
times.
90
—
—
BR290
BRH290
100
—
—
BR2100
BRH2100
	
residential
&
light
commercial
distribution
products 
PG.31.02.P.K
–
September
2011
www.eatoncanada.ca	
110
—
—
BR2110
BRH2110
125

#4 – 2/0

—
—

—
—

BR2125

BRH2125

17

Plug-In Circuit Breakers for CPM/CPL

Loadcenters
Circuit Breakers
Type GFXB &
Internationally
Rated Ground Fault & Type BR Moulded Case Switches
Type BR Loadcenters & Circuit Breakers
Type GFXB Internationally Rated Ground Fault Circuit Breakers
10,000/22,000 Amperes Interrupting Capacity
120 Vac and 120/240 Vac

♦ 3,000 Amperes Interrupting Capacity at 120/240VAC, 220/380VAC, and 240/415VAC.

GFCB Ground Fault Circuit Breakers — 5 Milliampere —
ProductType
Selection
1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 10,000 AIC

abc
Table 19.
30mA Single
Pole
Plug-In1-Pole
Ground Fault Circuit Breakers
Ampere
Wire Size
Range
2-Pole

Rating

Cu/Al 60°C or 75°C

120 Vac
Requires One
1-Inch
(25.4 mm)
Wire Space
Size Range
Cu/Al 60°C or 75°C
(AWG)
1 per Shelf Carton

120/240 Vac
1-Pole 120VAC
Common Trip
Two
1 Requires
per Shelf Carton
1-Inch
(25.4
mm)
3kAIC
Spaces
Catalogue Number a
1 per Shelf Carton

15

#14 -10,000
4
AIC

GFXB115B2
10,000 AIC

20

#14 -Catalog
4
Number �

Catalog
GFXB120B2
Number

#14 -GFCB115
4

GFXB125B2
GFCB215

Ampere Rating

25
30

15
20
25
30
40
50

#14 – 4

#14 -GFCB120
4
GFCB125
GFCB130
GFCB140
—

Type GFCB 1-Pole
Type GFXB

GFCB220
GFXB130B2

GFCB225
GFCB230
Requires
One 1-Inch (25.4mm) Space
GFCB240
GFCB250 �

Type GFCB 2-Pole

� Available with bell alarm or auxiliary switch. See circuit breaker accessories on Page 3-62.
Type BR
Non-Automatic Moulded Case Switches
�

For use with copper wire only.

ProductType
Selection
GFCBH Ground Fault Breakers — 5 Milliampere —

1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 22,000 AIC

Table 20. Two Pole Plug-In Non-Automatic Moulded Case Switches
Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

1-Pole
120 Vac
Requires One
Wire Size Range
1-Inch
Cu/Al 60°C or 75°C
(25.4 mm)
(AWG)
Space

Ampere Rating

c

2-Pole
120/240
Vac
2-Pole
120/240VAC
Common Trip
5Requires
per Shelf Carton
Two
1-Inch
Catalogue Number c
(25.4 mm)
Spaces

50

#4 - 1/0

60

#4 - 1/0
22,000 AIC

BR260NA
22,000 AIC

100

Catalog
#4 - 1/0

Catalog
BR2100NA

1 per Shelf Carton

Number

15
20
25
30

#14 – 4

GFCBH115
GFCBH120
GFCBH125
—

BR250NA

1 per Shelf Carton

Number
Requires Two 1-Inch (25.4mm) Spaces
GFCBH215
GFCBH220
GFCBH225
GFCBH230

Type GFEP Ground Fault Equipment Protectors (30 Milliampere),
1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 10,000 AIC
Ampere
Rating

15
20
25
30
40
50
�

Wire Size Range
Cu/Al 60°C or 75°C

#14 – 4

1-Pole
120 Vac
Requires One
1-Inch Space

2-Pole
120/240 Vac
Common Trip
Requires Two
1-Inch Spaces

1 per Shelf Carton

1 per Shelf Carton

10,000 AIC

10,000 AIC

Catalog
Number

Catalog
Number

GFEP115
GFEP120
GFEP125
GFEP130
—
—

GFEP215
GFEP220
GFEP225
GFEP230
GFEP240
GFEP250 �

For use with copper wire only.

Auxiliary switches and bell alarms are available under special order. Add suffix W1 for alarm switch and W2 for auxiliary switch.
Meets requirements of BS3871 section 31C and BS4293.
c
Non-stocked part requiring special ordering. Speak to your local Eaton sales rep for lead times.
a
b

18	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

BR250NA

Plug-In Loadcentre Main Circuit Breakers for CPM/CPL
Type CSR, BWH, & CC

Type CSR Loadcentre Main Circuit Breaker Kit
♦ 25,000 Amperes Interrupting Capacity at 120/240VAC.

Product Selection
Table 21. Two Pole Main Circuit Breakers for Single Phase Plug-In Combination Loadcentres
2-Pole 120/240VAC
1 per Shelf Carton
25kAIC

Ampere Rating

Wire Size Range
Cu/Al 60°C or 75°C

125

#2AWG - 300kcmil

CSR2125N

150

#2AWG - 300kcmil

CSR2150N

200

#2AWG - 300kcmil

CSR2200N

Catalogue Number

CSR2150N

Type BWH Loadcentre Main Circuit Breaker Kit
♦ 25,000 Amperes Interrupting Capacity at 120/240VAC.

Product Selection
Table 22. Two Pole Main Circuit Breakers for Single Phase Plug-In Combination Loadcentres
2-Pole 120/240VAC
1 per Shelf Carton
25kAIC

Ampere Rating

Wire Size Range
Cu/Al 60°C or 75°C

125

#2AWG - 300kcmil

BWH2125

150

#2AWG - 300kcmil

BWH2150

175

#2AWG - 300kcmil

BWH2175

200

#2AWG - 300kcmil

BWH2200

Catalogue Number

BWH2150

Type CC Loadcentre Main Circuit Breaker Kit
Product Selection
Table 23. Three Pole Main Circuit Breakers for Three Phase Plug-In Combination Loadcentres
3-Pole 120/240VAC
1 per Shelf Carton
10kAIC

Ampere Rating

Wire Size Range
Cu/Al 60°C or 75°C

100

#4AWG - 4/0AWG

CC3100

125

#2AWG - 300kcmil

CC3125

150

#2AWG - 300kcmil

CC3150

200

#2AWG - 300kcmil

CC3200

	

Catalogue Number

CC3150

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

19

Plug-In Circuit Breaker Accessories for CPM/CPL Loadcentres

Accessories for Types BR, DNPL, GFCB, GFEP, GFXB, CSR, BWH, & CC

Plug-In Circuit Breaker Accessories
Product Selection
Table 24. Field Installation Kits and Parts for Plug-In Loadcentre Circuit Breakers
Description

Ordering Qty. a

Catalogue
Number

Handle Tie for single pole Type BR circuit breakers. Joins handles on breakers mounted adjacent to each other via a clip-on mechanism.

1

BQHT-10

Handle Tie for Type DNPL circuit breakers. Joins the two outside independent poles on two adjacent Duplex or one Quadplex circuit breakers.

1

THOW-10

Handle Tie for Type DNPL circuit breakers. Joins the outside independent poles on adjacent Duplex or Quadplex circuit breakers.

1

THS1

Handle Lockoff (Escutcheon mounted). 1, 2, or 3-Pole Type BR; 1-pole of a Type DNPL Duplex or; one independent outside pole of a Type DNPL
Quadplex circuit breakers.

1

BRLW-10

Handle Lockoff b (Handle mounted). 1-Pole Type BR circuit breakers.

1

BRLW1-10

Handle Lockoff b (Handle mounted). 2 and 3-Pole Type BR circuit breakers.

1

BRLW2-10

Handle Lockoff

1

BRDL1-10

Handle Lockoff b (Escutcheon mounted). 2 pole Type DNPL Quadplex circuit breakers.

1

BRQLW-10

b

(Handle mounted). 1-Pole Type DNPL Quadplex circuit breakers.

Handle Lockoff

b

(Screw mounted). Locks the handle of main circuit breaker types CC and CHH in the OFF or ON position.

1

CCPL

Handle Lockoff

b

(Escutcheon mounted). Locks the handle of main circuit breaker type CSR and BWH in the OFF of ON position.

1

MCBPL

Handle Lockdog b (Escutcheon mounted). 1, 2, and 3-pole Type BR; 1-pole of a Type DNPL Duplex or; one independent pole of a Type DNPL
Quadplex circuit breaker. Secures handle in the ON or OFF position.

1

BHLW-10

Handle Lockdog b (Handle mounted). 1-pole Type BR circuit breakers. Secures handle in the ON or OFF position.

1

BHLW1-10

Handle Lockdog

1

BHLW2-10

Handle Lockdog b (Handle mounted). 1-pole Type GFCB ground fault circuit breakers. Secures handle in the ON or OFF position.

1

BHGW-10

Handle Lockdog
position.

1

HLW1-10

Main Breaker Lug Kit. Types CC and CHH circuit breakers (2) 300kcmil

1

CCL300

Main Breaker Lug Kit. Types CSR, BW, and BWH circuit breakers (2) 300kcmil

1

MCBL300

b

b

(Handle mounted). 2, and 3-pole Type BR circuit breakers. Secures handle in the ON or OFF position.
(Handle mounted). 1-pole Type DNPL Duplex or 1 outside independent pole of a Quadplex. Secures handle in the ON or OFF

Definitions
Handle Ties - devices used to join two similar independent single-pole circuit breakers to form a 2-pole non-common trip breaker.
Handle Lockoffs - devices that use a padlock to lock a circuit breaker’s handle in either the ON or OFF position.
Handle Lockdogs - devices used to secure a circuit breaker’s handle in the ON or OFF position. They are not padlockable devices.
Escutcheon Mounted - a semipermanent mounting to the face of the circuit breaker and secured by the loadcentre’s deadfront cover.
Handle Mounted - a mounting made directly to the handle of the circuit breaker by means of a set screw.
Screw Mounted - a permanent mounting to the face of the circuit breaker by means of a non-removable screw.

Circuit Breaker
Accessories
Circuit Breaker
Accessories
Circuit Breaker Accessories
Circuit Breaker Accessories
Circuit
Breaker
Accessories
Circuit
Breaker
Accessories

3

3

3

THS1

THS1

BHLW2

THS1
THS1

ssories

BHLW2
BRLW2
BREQS125 BREQS125
BRLW2
BREQS125
BHLW2
THS1
BRLW2
BHLW2-10
MCBPL
(Installed)
THOW (Installed)MCBPL (Installed)
BREQS125
BHLW2
BRLW2
MCBPL
THOW
(Installed)
THOW-10
MCBPL (Installed)
THOW (Installed)
(Installed)
(Installed)BRLW2
BREQS125
BREQS125
BHLW2BHLW2
THS1 THS1
BRLW2 THOW (Installed)
MCBPL (Installed)

3

3

(Installed)
THOW THOW
(Installed)
BRQLW

BRQLW

BHLW
BRQLW

BHLW

BRQLW

BHLW2

BRLW2
BRLW2-10

BHLW

BREQS125

BRHDK125 BRHDK125
BHLW
BRHDK125

BHLW
BHLWBHLW-10

BRQLWBRQLW
BRQLW-10

b

BRML

BRHDK125
BRHDK125

Must be purchased in multiples of ordering quantities indicated.
Refer to your local Eaton sales representative for handle position changeability chart.

20	

BHLW

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

BRHDK125

BRML

BRML

BRML

MCBPL (Installed)

THOW (Installed)
a

BRML
BRHDK125

MC

BRML BRM

Plug-In OEM Loadcentre Interior Assemblies

Product Description

As a leader in the electrical
distribution equipment business,
Eaton has a unique product offering
for equipment manufacturers, panel
builders and virtually any OEM that
has a need for power distribution
within their equipment. The OEM
interior offering consists of a wide
variety of power distribution options
utilizing components from Eaton’s
Eaton BR Loadcentre product lines.
With high-volume, standardized
products, OEMs can expect to receive
high-quality products covering
configurations meeting virtually any
power distribution need.
Coupled with Eaton’s expertise
in circuit breaker design and
manufacturing, our OEM interiors
provide solid power distribution and
circuit protection in a compact, easyto-install package.

Product Offering

The BR interiors are manufactured of
formed, plated aluminum, and use the
Eaton Type BR 1-inch (25.4 mm) wide
circuit breaker by Eaton Corporation.
This design affords customers the
most circuit flexibility as many of
these interiors allow the installation
of standard 1-and 2-pole breakers as
well duplex (2 poles in a 1-inch (25.4
mm) space) or quadplex (4 poles in
a 2-inch (50.8 mm) space) breakers.
The stab rating of the BR interiors is
140 amperes maximum, meaning that
the handle rating of the breakers that
are mounted across from one another
may not exceed 140 amperes.
The interiors are designed for either
horizontal (single-row breaker
mounting), or vertical (double-row
breaker mounting). To comply with
National Electrical Code (NEC)
requirements if mounted horizontally,
when the breaker is ”ON,” the handle
should be in the UP position. When
mounted vertically, the handle toggles
from left to right, so this is not a
concern.

Standards and
Certifications

Canadian Standards Association
Listing
All 1-pole and 2-pole, 120/240 volt
breakers, both 1-inch (25.4 mm), 1/2inch (12.7 mm) and 3/4-inch (19.1 mm)
per pole, 225 ampere maximum, are
listed as Certified by the Canadian
Standards Association, Guide No. 6911.19, Class 1432, File 18328.

All Eaton breakers where marked,
are suitable for use with 60/75˚ rated
wire, unless otherwise specified.
All devices comply with the
22kAIC-10kAIC UL series connected
components File DKSY2 of the
Recognized Components Index.

Underwriters Laboratories Listing
All grounding bars manufactured
comply with Underwriters
Laboratories standards and are listed
under Guide No. DHJR, File E31424,
Volume W, Section 17.
All circuit breakers 10 amperes and
larger comply with the Underwriters
Laboratories ”Standard for Branch
Circuit and Service Circuit-Breakers”
UL 489; Guide No. 60 10.2 File
E31424, and ”Requirements for Wire
Connectors and Soldering Lugs,”
UL486B, Guide No. 461 10-C File
E7830.

Product Selection
Table 25. Plug-In OEM Loadcentre Interior Assemblies
Ampere Rating

1” Spaces

½” Spaces

Main Terminal Size
(Per Phase)

Package Quantity

Catalogue Number

125

4

8

(1) 2/0 - #14 AWG Cu/Al

20

48INT125B

125

8

16

(1) 2/0 - #14 AWG Cu/Al

20

816INT125B

125

12

24

(1) 2/0 - #14 AWG Cu/Al

20

1224INT125B

125

16

24

(1) 2/0 - #14 AWG Cu/Al

20

1624INT125B

125

20

24

(1) 2/0 - #14 AWG Cu/Al

10

2024INT125B

125

24

24

(1) 2/0 - #14 AWG Cu/Al

10

2424INT125B

	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

21

Plug-In OEM Loadcentre Interior Assemblies

Dimensions

Figure 9. 48INT125B

Figure 10. 816INT125B
22	

Figure 11. 1224INT125B

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Plug-In OEM Loadcentre Interior Assemblies

Dimensions Continued

Figure 12. 1624INT125B

	

Figure 13. 2024INT125B

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

23

Plug-In OEM Loadcentre Interior Assemblies

Dimensions Continued

Figure 14. 2424INT125B

24	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Type CH Plug-In Loadcentres

Product Description

Loadcentres feature factory
installed main lugs or main
circuit breakers. The CH
interiors are manufactured
of formed, silver flash plated
copper. Eaton also supplies
a full line of Type CH branch
circuit breakers and accessories
for these loadcentres.

Product Application
Designed for the protection and
distribution of single and multidwelling residential and light
commercial loads to 120/240
volts AC, such as lighting,
heating, appliance and small
motor branch circuits. All Main
Circuit Breaker Combination
Loadcentres are CSA listed
for use as service entrance
equipment.

Ratings

Single phase, 3 wire, 120/240
volts AC. Mains through 200
amperes. Available with up
to 120 branch circuits. Main
breakers on 100 & 200 Amp
panels are rated at 35,000 AIC.

Metal Enclosure
Specifications

Enclosures are made of 16
gauge galvanized sheet steel
powder coated sandalwood
beige. The galvanized coating
provides corrosion protection.
Trims are similarly scratchresistant powder coated a
sandalwood beige colour to
match the tub. A combination
surface/flush cover with integral
door is supplied.
All plug-in loadcentres are CSA
listed to file LL98266.

Warranty

Limited lifetime.

Type CH Plug-On Neutral Loadcentre Features and Benefits
Ample Cable Entry Knockouts
• Sidewall, endwall, and backplane locations.
• Standard sizing for service entrance and branch circuit
cabling.
Commercial Grade Main Circuit Breaker
• 35kAIC series rated main circuit breaker.
• Highest in the industry.

Attractive Sandalwood Finish
• Esthetically appealing, scratch-resistant powder coating.
• Both tub and trim are painted.

Silver Flash Plated Copper Bus
• Provides superior connectivity.

Patented Stab Design
• Unique design provides a tight connection to the bus.
• Prevents the misapplication of non-approved branch circuit
breakers.

	

Large Service Entrance Section
• Straight-in wiring saves labour and material.
• Large cable bending space.

Inboard Neutral Connections
• Provides direct neutral connection for plug-on style ground
fault and arc fault circuit breakers.
• Ample additional 2/0 lugs provided - no kits necessary.

Steel Backpan
• Reliable breaker mounting.
• One-piece design provides superior stability.

Drywall Marking on Enclosure
• Indicates proper mounting depth for flush mounting
applications.

Single Keyhole Mounting
• One keyhole at the top and bottom provides easier
mounting and leveling.

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

25

Type CH Plug-In Loadcentres
Combination and Non-Combination Single Phase

3 Wire 120/240VAC Plug-On Neutral Style Combination Service Entrance Type 1 (Indoor)
Product Selection
Table 26. Type CH Main Circuit Breaker Plug-On Neutral Indoor Type 1 Loadcentres
Maximum
Ampere
Rating

Main
Breaker
Rating

Catalogue Number

Max.
No. 3/4”
Spaces

100 Amp
100 Amp

Dimensions [in (mm)]

Cover Style

Type of
Main Circuit
Breaker

H

W

D

Wire Size Range for
Main CU/AL

100 Amp

CHM24PN100

100 Amp

CHM32PN100

24

Flush/Surface

CSH

29-1/8 (739.8)

14-3/16 (360.4)

3-11/16 (93.7)

#2 - 300 kcmil

32

Flush/Surface

CSH

34-1/8 (866.8)

14-3/16 (360.4)

3-11/16 (93.7)

#2 - 300 kcmil

200 Amp

200 Amp

200 Amp

200 Amp

CHM32PN200

32

Flush/Surface

CSH

34-1/8 (866.8)

14-3/16 (360.4)

3-11/16 (93.7)

#2 - 300 kcmil

CHM42PN200

42

Flush/Surface

CSH

37 (939.8)

14-3/16 (360.4)

3-11/16 (93.7)

#2 - 300 kcmil

200 Amp

200 Amp

CHM60PN200L

60

Flush/Surface

CSH

39 (990.6)

14-3/16 (360.4)

3-11/16 (93.7)

#2 - 300 kcmil

3 Wire 120/240VAC Plug-On Neutral Style Non-Combination Service Entrance Type 1 (Indoor)
Product Selection
Table 27. Type CH Main Lug Only Plug-On Neutral Indoor Type 1 Loadcentres
Maximum
Ampere
Rating

Dimensions [in (mm)]
Catalogue Number

Max. No. 3/4”
Spaces

Cover Style

H

W

D

Wire Size Range for
Main CU/AL

125 Amp

CHNL24PN125

24

Flush/Surface

29-1/8 (739.8)

14-3/16 (360.4)

3-11/16 (93.7)

#2 - 300 kcmil

125 Amp

CHNL32PN125

32

Flush/Surface

34-1/8 (866.8)

14-3/16 (360.4)

3-11/16 (93.7)

#2 - 300 kcmil

225 Amp

CHNL32PN225

32

Flush/Surface

34-1/8 (866.8)

14-3/16 (360.4)

3-11/16 (93.7)

#2 - 300 kcmil

225 Amp

CHNL42PN225

42

Flush/Surface

37 (939.8)

14-3/16 (360.4)

3-11/16 (93.7)

#2 - 300 kcmil

3 Wire 120/240VAC Standard Neutral Non-Combination Type 3R

a

(Outdoor/Raintight)

Product Selection
Table 28. Type CH Main Lug Only Standard Neutral Outdoor/Raintight Type 3R
Maximum
Ampere
Rating

100 Amp

Maximum No.

Maximum No.

Catalogue Number

¾” Spaces

³/8” Spaces

Enclosure Style

RCCHL102

2

4

Indoor/Outdoor Type 3R

a

Loadcentres

H

W

D

Wire Size Range
for Main CU/AL
(AWG)

12 (304.8)

6-7/8 (174.62)

4-3/8

#14-1/0

Dimensions [in (mm)]

a

RCCHL102

Outdoor Loadcentres accommodate Type DS conduit hubs. Hubs not included. See page 11 for selection.
Does not accept plug-on neutral style of arc fault and ground fault circuit breakers. Uses standard type arc fault and ground fault circuit breakers.

Enclosure assembly incoporates a swing out locking hasp for the cover.
a


26	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Plug-In Circuit Breakers for CH
Type CH Single, Multi-Pole, & Twin

Type CH Plug-In Circuit Breakers



♦ 10,000 Amperes Interrupting Capacity at 120/240VAC
♦ Flag trip models provide visual indication of trip

Product Selection
Table 29. Single and Multi-Pole Plug-In Breakers
1-Pole 120/240VAC

1-Pole 120/240VAC

2-Pole 120/240VAC

2-Pole 120/240VAC

3-Pole 240VAC

Standard

Flag Trip Indication

Standard

Flag Trip Indication

Standard

10 per Shelf Carton

10 per Shelf Carton

5 per Shelf Carton

5 per Shelf Carton

5 per Shelf Carton

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

—

CH210

—

CH310



CHF115

CH215



CHF215

CH315 

Amperes

Wire Size Range
(Cu/AL 60ºC or 75ºC) (AWG)

10

(1) #14-8 , (2) #14-10  b, (1) #14-6 

CH110

15

(1) #14-8 , (2) #14-10

CH115

20

(1) #14-8 , (2) #14-10  b, (1) #14-6 

CH120  

CHF120

CH220 

CHF220

CH320 

25

(1) #14-8 , (2) #14-10

CH125



CHF125

CH225



CHF225

CH325 

30

(1) #14-8 , (2) #14-10  b, (1) #14-6 

CH130 

CHF130

CH230 

CHF230

CH330 

35

#14-2 , #14-6 

CH135 

—

CH235 

—

CH335 

40

#10-1/0 , #14-2 , #3-0

CH140



—

CH240



—

CH340 

45

#10-1/0 , #14-2 , #3-0 

CH145 

—

CH245 

—

CH345 

50

#10-1/0 , #14-2 , #3-0

CH150



—

CH250



—

CH350 

60

#10-1/0 , #14-2 , #3-0 

CH160 

—

CH260 

—

CH360 

70

#10-1/0 , #14-2 , #3-0 

CH170

—

CH270 

—

CH370 

80

#10-1/0 , #14-2 , #3-0



—

—

CH280

—

CH380

90

#10-1/0 , #14-2 , #3-0 

—

—

CH290

—

CH390

100

#10-1/0 , #14-2 , #3-0



—

—

CH2100

—

CH3100

110

#10-1/0 , #14-2 , #3-0



—

—

CH2110

—

—

125

#10-1/0 , #14-2 , #3-0 

—

—

CH2125

—

—














b

b










, (1) #14-6
, (1) #14-6









Requires One ¾-Inch (19.1mm) Space

Type CH Twin Circuit Breakers

Requires Two ¾-Inch (19.1mm) Spaces

Requires Three ¾-Inch (19.1mm) Spaces

 

♦ 10,000 Amperes Interrupting Capacity at 120/240VAC
♦ Provides 2 single-pole circuits in one ¾” space

Product Selection
Table 30. Twin Plug-In Circuit Breakers
1-Pole 120/240VAC
10 per Shelf Carton

Ampere Rating

Wire Size Range
(Cu/AL 60ºC or 75ºC) (AWG)

15-15

#14 - 8

CHNT1515

15-20

#14 - 8

CHNT1520

20-20

#14 - 8

CHNT2020

Catalogue Number

Requires One ¾-Inch (19.1mm) Space

For 1- and 2-pole breakers.
Solid and stranded wire can be used together.

For 3-pole breakers.

1-Pole 60-70 amperes, 2-pole 80-125 amperes, 3-pole 40-100 amperes.

1-Pole 40-50 amperes, 2-pole 40-70 amperes.

b

	

2-Pole 150 amperes.
Switching duty rated.

HACR rated.

Not for use in Type BR Loadcentres i.e. CPM or CPL prefixed catalogue numbers.



residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

27

Plug-In Circuit Breakers for CH
Type CHP Commercial

Type CHP Commercial Circuit Breakers



♦ 10,000 Amperes Interrupting Capacity at 120VAC, 120/240VAC, and 240VAC
♦ 3 Position trip breakers for commercial applications when On-Off and Trip position is required.

Product Selection
Table 31. Commercial Plug-In Circuit Breakers
1-Pole 120/240VAC

2-Pole 120/240VAC

3-Pole 240VAC

10 per Shelf Carton

5 per Shelf Carton

5 per Shelf Carton

Catalogue Number

Catalogue Number

Catalogue Number

CHP310

Amperes

Wire Size Range
(Cu/AL 60ºC or 75ºC) (AWG)

10

(1) #14-8 , (2) #14-10

CHP110

CHP210

15

(1) #14-8 a, (2) #14-10 a b, (1) #14-6 

CHP115  

CHP215 

CHP315 

20

(1) #14-8 , (2) #14-10

CHP120

CHP220



CHP320 

25

(1) #14-8 a, (2) #14-10 a b, (1) #14-6 

CHP125 

CHP225 

CHP325 

30

(1) #14-8 , (2) #14-10

CHP130

CHP230



CHP330 

35

#14-2 a, #14-6 

40

a

a

a

ab

ab

ab

, (1) #14-6

, (1) #14-6

, (1) #14-6











CHP135 

CHP235 

CHP335 

#10-1/0 , #14-2



CHP140 

CHP240 

CHP340 

45

#10-1/0 , #14-2



CHP145

CHP245



CHP345 

50

#10-1/0 , #14-2 

CHP150 

CHP250 

CHP350 

60

#10-1/0 , #14-2



CHP160

CHP260

CHP360 

70

#10-1/0 , #14-2 

CHP170

CHP270

CHP370

80

#10-1/0 , #14-2 

—

CHP280

—

90

#10-1/0 , #14-2



—

CHP290

—

100

#10-1/0 , #14-2 

—

CHP2100

CHP3100

110

#10-1/0 , #14-2



—

CHP2110

—

125

#10-1/0 , #14-2 

—

CHP2125

—

Requires One ¾-Inch (19.1mm) Space

Requires Two ¾-Inch (19.1mm) Spaces

Requires Three ¾-Inch (19.1mm) Spaces
















.

For 1- and 2-pole breakers.
Solid and stranded wire can be used together.

For 3-pole breakers.

1-Pole 60-70 amperes, 2-pole 80-125 amperes, 3-pole 40-100 amperes.

1-Pole 40-50 amperes, 2-pole 40-70 amperes.

Switching duty rated.

HACR rated.

Not for use in Type BR Loadcentres i.e. CPM or CPL prefixed catalogue numbers.
a
b

28	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Plug-In Circuit Breakers for CH
Type CH Arc Fault Circuit Interrupter

Type CH Arc Fault Circuit Interrupter Circuit Breakers



♦ 10,000 Amperes Interrupting Capacity at 120VAC, and 120/240VAC
♦ Plug-On Neutral style for Plug-On Neutral type CH loadcentres

Product Description

A Branch Feeder Type Arc Fault Circuit Interrupter is a device intended to mitigate parallel arcing faults in the complete circuit, including connected cords.
Parallel arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all
arcing faults..
Figure 15 1-Pole Single 120V Load
Application Sourced by 120/240VAC

Product Selection
Table 32. Single and Two Pole Plug-In FIRE-GUARD™ AFCI Circuit Breakers
1-Pole 120/240VAC

2-Pole 120/240VAC

10 per Shelf Carton

5 per Shelf Carton

10kAIC

10kAIC a b

Ampere
Rating

Wire Size Range
(Cu/AL 60ºC or 75ºC)
(AWG)

Configuration

Catalogue Number

Catalogue Number

15

#14 - 4

Standard

CH115AF

—

15

#14 - 4

Common Trip

—

CH215AF

15

#14 - 4

Independent Trip

—

CH215AFIT

15

#14 - 4

Plug-On Neutral 

CH115AFPN

—

20

#14 - 4

Standard

CH120AF

20

#14 - 4

Common Trip

—

CH220AF

20

#14 - 4

Independent Trip

—

CH220AFIT

20

#14 - 4

Plug-On Neutral

CH120AFPN

—

Requires One ¾-Inch (19.1mm) Space

Requires Two ¾-Inch (19.1mm) Spaces



Figure 16 2-Pole Shared Neutral with
Multi-Duplex Receptacle Application

Figure 17  2-Pole 240V Load
Application Sourced by 120/240VAC

Figure 18 2-Pole Shared Neutral with
Duplex Receptacle Application

Type CH 1-Pole AFCI Circuit Breaker

Common trip refers to 2-pole 240 volt load application sourced by 120/240 Vac (see Figure 17).
Independent trip refers to 2-pole multi-wire, home run or shared neutral circuits (see Figure 16 and Figure 18).

Not for use in Type BR Loadcentres i.e. CPM or CPL prefixed catalogue numbers.

Only for use in the Type CH Plug-On Neutral style of combination and non-combination loadcentres.
a
b

	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

29

Plug-In Circuit Breakers for CH
Type CH Ground Fault

Type CH Ground Fault Circuit Breakers

b

♦ 10,000 Amperes Interrupting Capacity at 120VAC and 120/240VAC
♦ 5mA “People Protection” or 30mA Equipment Protectors
♦ Two pole version features common trip.

Product Selection
Table 33. 5mA Single and Two Pole Plug-In Ground Fault Circuit Breakers
1-Pole 120VAC

1-Pole 120VAC

2-Pole 120/240VAC

Standard

Plug-On Neutral 

Standard

1 per Shelf Carton

1 per Shelf Carton

1 per Shelf Carton

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C
(AWG)

10kAIC

10kAIC

10kAIC

Catalogue Number

Catalogue Number

Catalogue Number

15

#14 - 6 a

CH115GF

CH115GFPN 

CH215GF

20

#14 - 6 a

CH120GF

CH120GFPN 

CH220GF

25

#14 - 6 a

CH125GF

—

CH225GF

30

#14 - 6

CH130GF

—

CH230GF

35

#14 - 6 a

—

—

CH235GF

40

#14 - 6 a

—

—

CH240GF

45

#14 - 6

a

—

—

CH245GF

50

#14 - 6 a

—

—

CH250GF

60

#14 - 6

—

—

CH260GF

a

a

Requires One ¾-Inch (19.1mm) Space

Figure 19 1-Pole Single 120V
Duplex Receptacle Application

Type CH 2-Pole
GFCI Circuit Breaker

Figure 20 2-Pole 120V MultiDuplex Receptacle Application

Requires Two ¾-Inch (19.1mm) Spaces

Table 34. 30mA Single and Two Pole Plug-In Ground Fault Circuit Breaker Equipment Protectors
1-Pole 120VAC

2-Pole 120/240VAC

1 per Shelf Carton

1 per Shelf Carton

10kAIC

10kAIC

Ampere Rating

Wire Size Range
Cu/Al 60°C or 75°C
(AWG)

Catalogue Number

Catalogue Number

15

#14 - 6 a

CH115EPD

CH215EPD

20

#14 - 6

a

CH120EPD

CH220EPD

25

#14 - 6 a

CH125EPD

—

30

#14 - 6

CH130EPD

CH230EPD

40

#14 - 6 a

—

CH240EPD

50

#14 - 6 a

—

CH250EPD

60

#14 - 6

—

CH260EPD

Requires One ¾-Inch (19.1mm) Space

Requires Two ¾-Inch (19.1mm) Spaces

a

a

Figure 21 2-Pole 120V Duplex
Receptacle Application

Figure 22  2-Pole 240V Duplex
Receptacle Application

Ground Fault Application Note
Single-pole ground fault circuit breakers (Type CHGFIs) are designed for use in 2-wire, 120VAC circuits. Figure 19 shows a typical wiring configuration.
Two-pole ground fault circuit breakers (Type CHGFIs) are designed for use in 3-wire, 120/240VAC circuits, 120VAC multi-wire circuits employing common, neutral and 2-wire, 240VAC
circuits obtained from a 120/240VAC source.
Figures 20 and 21 illustrate typical wiring configurations for 120/240VAC multi-wire circuits.
Figure 22 depicts a 240VAC, 2-wire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection
is necessary to supply a 120VAC power source to the ground fault sensing circuit.
The figures are shown with a 120/240VAC, single-phase, 3-wire power source, but are also applicable to a 120/208VAC, 3-phase, 4-wire power supply. For all figures the electrical
operation of the Type CHGFI is not affected by the equipment ground.
60 Ampere breaker listed for 75°C Cu wire only
Not for use in Type BR Loadcentres i.e. CPM or CPL prefixed catalogue numbers.

Only for use in the Type CH Plug-On Neutral style of combination and non-combination loadcentres.
a
b

30	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Plug-In Loadcentre Main Circuit Breakers for CH
Type CSH

Type CSH Loadcentre Main Circuit Breaker Kit
♦ 35,000 Amperes Interrupting Capacity at 120/240VAC.

Product Selection
Table 35. Two Pole Main Circuit Breakers for Single Phase Plug-In Combination Loadcentres
2-Pole 120/240VAC
1 per Shelf Carton
35kAIC

Ampere Rating

Wire Size Range
Cu/Al 60°C or 75°C

100

#2AWG - 300kcmil

CSH2100N

150

#2AWG - 300kcmil

CSH2150N

200

#2AWG - 300kcmil

CSH2200N

	

Catalogue Number

CSH2150N

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

31

Plug-In Loadcentres & Circuit Breaker Accessories for CH
Type CH Accessories

Plug-In Loadcentre and Circuit Breaker Accessories for CH
Product Selection
Table 36. Field Installation Kits and Parts for Plug-In Loadcentres and Circuit Breakers
Description

Ordering Qty. a

Catalogue
Number

Handle Tie for single pole Type CH circuit breakers. Joins handles on breakers mounted adjacent to each other via a moulded plastic handle
cover.

1

CHHT

Handle Lockoff (Escutcheon mounted). 1, or 2-Pole Type CH circuit breakers.

1

CHPL

Handle Lockoff (Escutcheon mounted). 1, or 2-Pole Type CHGFI circuit breakers.

1

CHPLGF

Handle Lockoff (Escutcheon mounted). Locks the handle of main circuit breaker type CSH in the OFF of ON position.

1

MCBPL

Handle Lockdog (Handle mounted). 1-pole Type CH circuit breakers. Secures handle in the ON or OFF position.

1

CHLO

Sub-feed kit for 125A Loadcentres. Requires Two 3/4” (19.1mm) spaces.

1

CHSF2125

3/4” (19.1mm) Filler plate kit

1

CHFP a

Door lock for 24-60 circuit 100 and 200A (CH).

1

TDL b

Trim screw kit (CH)

1

LCCS c

Sandalwood plastic replacement door latch

1

CHRLS

Branch Circuit Numbering Strip Kit for CH

1

CHNS d

a

Definitions
Handle Ties - devices used to join two similar independent single-pole circuit breakers to form a 2-pole non-common trip breaker.
Handle Lockoffs - devices that use a padlock to lock a circuit breaker’s handle in either the ON or OFF position.
Handle Lockdogs - devices used to secure a circuit breaker’s handle in the ON or OFF position. They are not padlockable devices.
Escutcheon Mounted - a semipermanent mounting to the face of the circuit breaker and secured by the loadcentre’s deadfront cover.
Handle Mounted - a mounting made directly to the handle of the circuit breaker by means of a set screw.
Screw Mounted - a permanent mounting to the face of the circuit breaker by means of a non-removable screw.

	

a

b	
c	

	

d

32	

Kit includes 25 pieces.
Comes with a set of keys.
Kit includes 25 pieces.
Kit includes 20 pieces.
Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Type CBM Bolt-On Loadcentres

Combination (Main Circuit Breaker) Single & Three Phase Aluminum Bus

Single Phase 120/240VAC Type 1 (Indoor) Loadcentres
♦ CSA Certified only (Not UL Approved)
♦ Utilize Type BAB, QBHW, QBA, DNBA, or QBGF circuit breakers as branch circuit breakers.

Product Selection
Table 37. Single Phase 3 Wire 120/240VAC Aluminum Bus Loadcentres
Maximum
Ampere
Rating

Main
Breaker
Rating

Catalogue
Number

Dimensions (Inches / mm)

125
125

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for Main CU/AL

100

CBM118

a

18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

100

CBM130 a

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

125

100

CBM142

a

42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

225

200

CBM218 b

18

36

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#4 - 4/0

225

200

CBM230

b

30

60

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#4 - 4/0

225

200

CBM242 b

42

84

Flush/Surface

45 / 1143

14-1/4 / 361.9

3-3/4 / 95.3

#4 - 4/0

Three Phase 240VAC Type 1 (Indoor) Loadcentres
♦ CSA Certified only (Not UL Approved)
♦ Utilize Type BAB, QBHW, QBA, DNBA, or QBGF circuit breakers as branch circuit breakers.

Product Selection
Table 38. Three Phase 4 Wire 240VAC Maximum Aluminum Bus Loadcentres
Maximum
Ampere
Rating

Main
Breaker
Rating

Catalogue
Number

Dimensions (Inches / mm)

125
125

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for Main CU/AL

100

3CBM118



18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

100

3CBM130 

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

125

100

3CBM142



42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

225

200

3CBM218



18

36

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#4 - 4/0

225

200

3CBM230 

30

60

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#4 - 4/0

225

200

3CBM242

42

84

Flush/Surface

45 / 1143

14-1/4 / 361.9

3-3/4 / 95.3

#4 - 4/0



3CBM242

a
b



BAB2100 Main circuit breaker factory installed.
ED2200 Main circuit breaker factory installed.
BAB3100H Main circuit breaker factory installed.
ED3200 Main circuit breaker factory installed.
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

33

Type CBM Bolt-On Loadcentres

Combination (Main Circuit Breaker) Single & Three Phase Copper Bus

Single Phase 120/240VAC Type 1 (Indoor) Loadcentres
♦ CSA Certified only (Not UL Approved)
♦ Utilize Type BAB, QBHW, QBA, DNBA, or QBGF circuit breakers as branch circuit breakers.

Product Selection
Table 39. Single Phase 3 Wire 120/240VAC Copper Bus Loadcentres
Maximum
Ampere
Rating

Main
Breaker
Rating

Catalogue
Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Dimensions (Inches / mm)
Cover Style

H

W

D

Wire Size Range for Main CU/AL

125

100

CBM118CU a

18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

125

100

CBM130CU

a

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

125

100

CBM142CU a

42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

225

200

CBM218CU

b

18

36

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#4 - 4/0

225

200

CBM230CU

b

30

60

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#4 - 4/0

Three Phase 240VAC Type 1 (Indoor) Loadcentres
♦ CSA Certified only (Not UL Approved)
♦ Utilize Type BAB, QBHW, QBA, DNBA, or QBGF circuit breakers as branch circuit breakers.

Product Selection
Table 40. Three Phase 4 Wire 240VAC Maximum Copper Bus Loadcentres
Maximum
Ampere
Rating

Main
Breaker
Rating

Catalogue
Number

125
125

Dimensions (Inches / mm)

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for Main CU/AL

100

3CBM118CU



18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

100

3CBM130CU 

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

125

100

3CBM142CU



42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#8 - #1 Cu / #8 - 1/0 Al

225

200

3CBM230CU



30

60

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#4 - 4/0

a
b



BAB2100 Main circuit breaker factory installed.
ED2200 Main circuit breaker factory installed.
BAB3100H Main circuit breaker factory installed.
ED3200 Main circuit breaker factory installed.

34	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Type CBL Bolt-On Loadcentres

Non-Combination (Main Lug Only) Single & Three Phase Aluminum Bus

Single Phase 120/240VAC Type 1 (Indoor) Loadcentres
♦ CSA Certified only (Not UL Approved)
♦ Utilize Type BAB, QBHW, QBA, DNBA, or QBGF circuit breakers as branch circuit breakers.

Product Selection
Table 41. Single Phase 3 Wire 120/240VAC Aluminum Bus Loadcentres
Dimensions (Inches / mm)

Maximum Ampere
Rating

Catalogue Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for Main
Cu/Al

125

CBL118

18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

125

CBL130

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

125

CBL142

42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

CBL218

18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

CBL230

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

CBL242

42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

Three Phase 240VAC Type 1 (Indoor) Loadcentres
♦ CSA Certified only (Not UL Approved)
♦ Utilize Type BAB, QBHW, QBA, DNBA, or QBGF circuit breakers as branch circuit breakers.

Product Selection
Table 42. Three Phase 4 Wire 240VAC Aluminum Bus Loadcentres
Dimensions (Inches / mm)

Maximum Ampere
Rating

Catalogue Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for Main
Cu/Al

125

3CBL118

18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

125

3CBL130

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

125

3CBL142

42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

3CBL218

18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

3CBL230

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

3CBL242

42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

CBL130

	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

35

Type CBL Bolt-On Loadcentres

Non-Combination (Main Lug Only) Single & Three Phase Copper Bus

Single Phase 120/240VAC Type 1 (Indoor) Loadcentres
♦ CSA Certified only (Not UL Approved)
♦ Utilize Type BAB, QBHW, QBA, DNBA, or QBGF circuit breakers as branch circuit breakers.

Product Selection
Table 43. Single Phase 3 Wire 120/240VAC Copper Bus Loadcentres
Maximum Ampere
Rating

Dimensions (Inches / mm)

Catalogue Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for
Main Cu/Al

125

CBL118CU

18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

125

CBL130CU

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

125

CBL142CU

42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

CBL218CU

18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

CBL230CU

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

CBL242CU

42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

Three Phase 240VAC Type 1 (Indoor) Loadcentres
♦ CSA Certified only (Not UL Approved)
♦ Utilize Type BAB, QBHW, QBA, DNBA, or QBGF circuit breakers as branch circuit breakers.

Product Selection
Table 44. Three Phase 4 Wire 240VAC Copper Bus Loadcentres
Dimensions (Inches / mm)

Maximum Ampere
Rating

Catalogue Number

Max. No. 1”
Spaces

Max. No. 1/2”
Spaces

Cover Style

H

W

D

Wire Size Range for
Main Cu/Al

125

3CBL118CU

18

36

Flush/Surface

27 / 685.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

125

3CBL130CU

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

125

3CBL142CU

42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

3CBL230CU

30

60

Flush/Surface

34-1/8 / 866.8

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

225

3CBL242CU

42

84

Flush/Surface

39 / 990.6

14-1/4 / 361.9

3-3/4 / 95.3

#6-300MCM

36	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Bolt-On Circuit Breakers for CBM/CBL
Type BAB & QBHW Single & Multi-Pole

Type BAB and QBHW
♦ 10,000 / 22,000 Amperes Interrupting Capacity at 120VAC, 120/240VAC, and 240VAC

Product Selection
Table 45. Single and Multi-Pole Bolt-On Circuit Breakers
1-Pole 120/240VAC

1-Pole 120/240VAC

2-Pole 120/240VAC

2-Pole 120/240VAC

3-Pole 120/240VAC

3-Pole 120/240VAC

10kAIC

22kAIC

10kAIC

22kAIC

10kAIC

22kAIC

Ampere Rating

Wire Size Range
(Cu/AL 60ºC or 75ºC) (AWG)

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

10

#14 - 4

BAB1010

—

—

—

—

—

15

#14 - 4

BAB1015

QBHW1015

BAB2015

QBHW2015

BAB3015H

QBHW3015

20

#14 - 4

BAB1020

QBHW1020

BAB2020

QBHW2020

BAB3020H

QBHW3020

25

#14 - 4

BAB1025

—

—

—

—

—

30

#14 - 4

BAB1030

QBHW1030

BAB2030

QBHW2030

BAB3030H

QBHW3030

40

#14 - 4

BAB1040

QBHW1040

BAB2040

QBHW2040

BAB3040H

QBHW3040

50

#14 - 4

BAB1050

QBHW1050

BAB2050

QBHW2050

BAB3050H

QBHW3050

60

#8 - 1 CU, #8 - 1/0 AL

BAB1060

QBHW1060

BAB2060

QBHW2060

BAB3060H

QBHW3060

70

#8 - 1 CU, #8 - 1/0 AL

BAB1070

QBHW1070

BAB2070

QBHW2070

BAB3070H

QBHW3070

90

#8 - 1 CU, #8 - 1/0 AL

—

—

BAB2090

QBHW2090

BAB3090H

QBHW3090

100

#8 - 1 CU, #8 - 1/0 AL

—

—

BAB2100

QBHW2100

BAB3100H

QBHW3100

125

#8 - 1 CU, #8 - 1/0 AL

—

—

BAB2125

QBHW2125

—

—

Requires One 1-Inch (25.4mm) Space

Requires Two 1-Inch (25.4mm) Spaces

Requires Three 1-Inch (25.4mm) Spaces

Type BAB High Intensity Discharge (HID) Rated
♦ 10,000 Amperes Interrupting Capacity at 120VAC, 120/240VAC, and 240VAC

Product Selection
Table 46. Single-Pole HID Rated Bolt-On Circuit Breakers
1-Pole 120/240VAC
10kAIC

Ampere Rating

Wire Size Range	
(Cu/AL 60ºC or 75ºC) (AWG)

15

#14 - 4

BAB1015D

20

#14 - 4

BAB1020D

Catalogue Number

Requires One 1-Inch (25.4mm)
Space

	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

37

Bolt-On Circuit Breakers for CBM/CBL
Type QBA Arc Fault Circuit Interrupter & DNBA Duplex

Type QBA Arc Fault Circuit Interrupter Circuit Breakers
♦ 10,000 / 22,000 Amperes Interrupting Capacity at 120VAC, 120/240VAC, and 240VAC

Product Selection
Table 47. Single and Two Pole Bolt-On FIRE-GUARD™ AFCI Circuit Breakers
1-Pole 120/240VAC

1-Pole 120/240VAC

2-Pole a b 120/240VAC

2-Pole a b 120/240VAC

10kAIC

22kAIC

10kAIC

22kAIC

Ampere Rating

Configuration

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

Wire Size Range
(Cu/AL 60ºC or 75ºC)
(AWG)

15

Standard

QBAF1015

QBHAF1015

—

—

#14 - 4

15

with GFCI

QBAG1015

QBHAG1015

—

—

#14 - 4

15

Common Trip

—

—

QBAF2015

QBHAF2015

#14 - 4

15

Independent Trip

—

—

QBAF2015IT

QBHAF2015IT

#14 - 4

15

Common Trip with GFCI

—

—

QBAG2015

QBHAG2015

#14 - 4

20

Standard

QBAF1020

QBHAF1020

—

—

#14 - 4

20

with GFCI

QBAG1020

QBHAG1020

—

—

#14 - 4

20

Common Trip

—

—

QBAF2020

QBHAF2020

#14 - 4

20

Independent Trip

—

—

QBAF2020IT

QBHAF2020IT

#14 - 4

20

Common Trip with GFCI

—

QBAG2020

QBHAG2020

#14 - 4

—
Requires One 1-Inch
(25.4mm) Space

Requires One 1-Inch
(25.4mm) Space

Requires Two 1-Inch
(25.4mm) Spaces

Requires Two 1-Inch
(25.4mm) Spaces

Type DNBA Duplex Circuit Breakers
♦ 10,000 Amperes Interrupting Capacity at 120/240VAC
♦ Provides 2 single-pole circuits in one 1” space

Product Selection
Table 48. Twin Plug-In Circuit Breakers
1-Pole 120/240VAC
10 per Shelf Carton

Ampere Rating

Wire Size Range
(Cu/AL 60ºC or 75ºC) (AWG)

15-15

#14 - 4

DNBA1515

20-20

#14 - 4

DNBA2020

30-30

#14 - 4

DNBA3030

Catalogue Number

Figure 23. 1-Pole Single 120V Load
Application Sourced by 120/240VAC

Figure 25.  2-Pole 240V Load
Application Sourced by 120/240VAC

Figure 24. 2-Pole Shared Neutral with
Multi-Duplex Receptacle Application

Figure 26. 2-Pole Shared Neutral with
Duplex Receptacle Application

Requires One 1-Inch (25.4mm) Space

a
b

Common trip refers to 2-pole 240 volt load application sourced by 120/240 Vac (see Figure 25).
Independent trip refers to 2-pole multi-wire, home run or shared neutral circuits (see Figure 24 and Figure 26).

38	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Bolt-On Circuit Breakers for CBM/CBL
Type QBGF & QBGFEP Ground Fault

Type QBGF and QBGFEP Ground Fault Circuit Breakers
♦ 10,000 / 22,000 Amperes Interrupting Capacity at 120VAC and 120/240VAC
♦ 5mA “People Protection” or 30mA Equipment Protectors
♦ Two pole version features common trip.

Product Selection
Table 49. 5mA Single and Two Pole Bolt-On Ground Fault Circuit Breakers
1-Pole 120VAC

2-Pole 120/240VAC

1 per Shelf Carton

1 per Shelf Carton

10kAIC

10kAIC

Catalogue Number

Catalogue Number

Ampere Rating

Wire Size Range
Cu/Al 60°C or 75°C (AWG)

15

#14 - 10 CU, #12 - 10 AL

QBGF1015

QBGF2015

20

#14 - 10 CU, #12 - 10 AL

QBGF1020

QBGF2020

30

#10 CU #8 AL

QBGF1030

QBGF2030

40

#8 CU #8 - 6 AL

QBGF1040

QBGF2040

50

#8 - 6 CU #6 - 4 AL

—

QBGF2050
Requires One 1-Inch (25.4mm) Space

Requires Two 1-Inch (25.4mm) Spaces

Table 50. 30mA Single and Two Pole Bolt-On Ground Fault Circuit Breaker Equipment Protectors
1-Pole 120VAC

1-Pole 120VAC

2-Pole 120/240VAC

2-Pole 120/240VAC

1 per Shelf Carton

1 per Shelf Carton

1 per Shelf Carton

1 per Shelf Carton

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C
(AWG)

10kAIC

22kAIC

10kAIC

22kAIC

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

15

#14 - 4

QBGFEP1015

QBHGFEP1015

QBGFEP2015

QBHGFEP2015

20

#14 - 4

QBGFEP1020

QBHGFEP1020

QBGFEP2020

QBHGFEP2020

25

#14 - 4

QBGFEP1025

QBHGFEP1025

QBGFEP2025

QBHGFEP2025

30

#14 - 4

QBGFEP1030

QBHGFEP1030

QBGFEP2030

QBHGFEP2030

Requires One 1-Inch (25.4mm) Space

Requires Two 1-Inch (25.4mm) Spaces

Requires One 1-Inch (25.4mm) Space

	

Requires Two 1-Inch (25.4mm) Spaces

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

39

Bolt-On Loadcentre & Circuit Breaker Accessories

Bolt-On Accessories
Product Selection
Table 51. Field Installation Kits and Parts for Bolt-On Loadcentres and Circuit Breaker
Description

Ordering Qty.

Catalogue Number

Handle Lockoff 1 Pole of Type DNBA Duplex Circuit Breakers (Package of 10).

1

BRDL1-10

Handle Lockoff Type BQL circuit breakers

1

BQL-10

Handle Lockoff Type BAB and QBHW circuit breakers

1

QL123PL

Handle Lockdog 1-pole Type BAB and QBHW circuit breakers

1

QL1NPL

Handle Lockdog 2 and 3-pole Type BAB and QBHW circuit breakers.

1

QL23NPL

Filler Plates 1” Space (Package of 24)

1

BRFP

Sub Feed Lug 100A (For Main Lug panel style)

1

CBSF100

Sub Feed Lug 225A (For Main Lug panel style)

1

CBSF225

Sub Feed Lug Kit 100A 3 Phase (For Main Lug panel style)

1

3CBSF100

Sub Feed Lug Kit 225A 3 Phase (For Main Lug panel style)

1

3CBSF225

Circuit Breaker Directory Card 1-42 (Package of 50)

1

DIRCARD42

Circuit Breaker Directory Sleeve (Package of 25)

1

DIRSLEEVE

Loadcentre Door Lock

1

TDL

Isolated Ground Kit

1

ISGRD

Definitions
Handle Lockoffs - devices that use a padlock to lock a circuit breaker’s handle in either the ON or OFF position.
Handle Lockdogs - devices used to secure a circuit breaker’s handle in the ON or OFF position. They are not padlockable devices.

40	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Manual Transfer Switches / Generator Panels

Product Description
A Transfer Switch Panel is a
device that is mounted next to or
incorporated within the loadcentre
(distribution panel) in the home or
small business. The Transfer Switch
Panel is used in conjunction with
an emergency generator (usually
supplied by others) and serves the
purpose of turning selected circuits
on and off during a power outage.
The Transfer Switch Panel allows the
owner to start up a generator and
then restore power to critical circuits
when utility power is not available.
The owner designates which circuits
are critical such as their refrigerator,
furnace, and certain lighting loads.
Sometimes called Emergency Power
Panels, Emergency Generator Panels,
Gen. Panels, Transfer Switches or
Emergency Panels; Transfer Switch
Panels provide the homeowner or
small business owner with a safe and
easy way to continue using essential
electrical loads when utility power is
not available.

Application Description
Transfer Switch Panels are most
often used in residential, agricultural
and light commercial applications.
Comfort and safety are key concerns
of many homeowners who are
dependent on an uninterrupted supply
of electricity.
The increase in our dependence on
power is due in part to the popularity
of home business and in-home care.
In addition, various rural and urban
regions in North America experience
periodic power outages due to
extreme weather conditions such as
ice and snowstorms, heat waves,
tornadoes or hurricanes. Regions
such as Pacific, Atlantic, and Central
are the strongest markets for portable
generators and Transfer Switch
Panels.

Features, Functions,
and Benefits
Eaton offers two unique manual
transfer switch emergency power
solutions.
♦	Manual Transfer Switches or a
Generator sub-panel.
♦	Combination Service Entrance
Loadcentre with Generator Subpanel.

	

Important:
Before installation, consult
appropriate electrical codes.
Installation information is included in
the carton.

Manual Transfer
Switches/ Generator
Panels

Product Specifications
♦	10,000 AIC rating.
♦	Switching devices must be circuit
breakers.
♦	Transfer switch panel must be
supplied with neutral and ground.

Combination Service
Entrance Loadcentre
Generator Panel

Standards and
Certifications
♦	CSA approved.

Product Specifications
♦	10,000 AIC rating for CPM126GEN
♦	25,000 AIC rating for CPM236GEN
♦	Switching devices must be circuit
breakers.
♦	Transfer switch panel must be
supplied with neutral and ground.

CPL112GI3 (30A only)
♦	Main utility and emergency
(generator) breaker factory
installed.
♦	Available in 30 and 60 ampere
design.
♦	Utility breaker and generator
breakers are mechanically
interlocked to protect equipment
and personnel by preventing
dangerous dual-source feeding.
♦	Critical loads permanently
connected to allow for quick and
convenient switching from utility
power to stand-by generator
power.
♦	Designed for switched neutral
applications. Can be reconfigured
in field for non-switched neutral
applications.
♦	Sturdy and reliable 125A rated
aluminum bus design.
♦	Type BR/DNPL branch breakers sold
separately.
♦	Ideal for new and retrofit
installations.
♦	EEMAC 1 indoor enclosure design.
♦	CPL112GI3 special features
	 - NEMA L14-30 Inlet for generator
connection.
	 - Two Watt meters measure power
consumption on L1 and L2 to aid in
balancing

Standards and
Certifications

CPM126GEN
♦	Single enclosure (EEMAC 1)
to house both loadcentre and
generator breakers
♦	Factory installed main breakers.
♦	Available in 100 and 200 ampere
designs.
♦	Utility and emergency transfer
switch breaker factory installed.
♦	Utility breaker and generator
breakers are mechanically
interlocked to protect equipment
and personnel by preventing
dangerous dual-source feeding.
♦	Critical loads permanently
connected to allow for quick and
convenient switching from utility
power to stand-by generator
power.
♦	Designed for switched neutral
applications. Can be reconfigured
in field for non-switched neutral
applications.
♦	Type BR/DNPL branch breakers sold
separately.
♦	Ideal for new and retrofit
installations.
♦	EEMAC 1 indoor enclosure design.

♦	CSA approved.

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

41

Manual Transfer Switches / Generator Panels

Product Selection
Table 52. Manual Transfer Switches/ Generator Panels
Catalogue
Number

Bus Rating
(A)

Generator
Breaker (A)

Switched
Neutral

Enclosure
Rating

Max. Total Branch
Circuits (1”/½”)

Inlet
Receptacle
Type

Height Branch Circuits
(Inches / mm)

Width
(Inches / mm)

Depth
(Inches / mm)

CPL112G3

125

30

Yes

EEMAC 1

6 / 12

-

16.750 / 425.45

14.375 / 365.13

3.875 / 98.43

CPL112G6

125

60

Yes

EEMAC 1

6 / 12

-

16.750 / 425.45

14.375 / 365.13

3.875 / 98.43

CPL120G6

125

60

Yes

EEMAC 1

14 / 28

-

21.000 / 533.40

14.375 / 365.13

3.875 / 98.43

CPL130G6

125

60

Yes

EEMAC 1

24 / 48

-

29.125 / 739.78

14.375 / 365.13

3.875 / 98.43

CPL112GI3

125

30

Yes

EEMAC 1

6 / 12

L14-30

16.750 / 425.45

14.375 / 365.13

3.875 / 98.43

RCPL112GI3

125

30

Yes

EEMAC 3

6 / 12

L14-30

16.50 / 419.10

14.375 / 365.13

5 / 127.00

Table 53. Combination Service Entrance Loadcentre Generator Panel
Catalogue Number

Bus Rating
(A)

Loadcentre Main
Breaker (A)

Max. Total Branch
Circuits (1”/½”)

Generator
Breaker (A)

Switched
Neutral

Max. Generator
Branch Circuits

Height
(Inches / mm)

Width
(Inches / mm)

Depth
(Inches / mm)

CPM126GEN

125

100

26/52

30

Yes

6/12

39.000 / 990.60

14.375 / 365.13

3.875 / 98.43

CPM236GEN

200

200

36/72

60

Yes

6/12

45.000 / 1143

14.375 / 365.13

3.875 / 98.43

Table 54. Portable Generator Power Inlet Box
Catalogue Number

Ampere Rating (A)

Inlet Receptacle Type

Enclosure Rating

Height
(Inches / mm)

Width
(Inches / mm)

Depth
(Inches / mm)

CH10EGENPIB a

30

L14-30

NEMA 3R

6-1/16 / 153.99

5-9/16 / 141.29

5-3/8 / 136.52

Figure 27. Typical Installation Diagram

	

Notes:

♦	Combination Service Entrance Loadcentre Generator Panels come complete with an integrated emergency generator
panel.
♦	Combination Service Entrance Loadcentre Generator Panels come complete with factory installed utility feeder
breaker for emergency generator panel section.
* Not Included
a

Not CSA approved.

42	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Spa Panels

Single Phase 3-Wire 120/240VAC Ground Fault Circuit Interrupter Spa Panels
♦ Factory assembled, prewired, tested, and ready to install.
♦ Two-Pole 5mA “People Protection” type CH Ground fault circuit interrupter circuit breaker.
♦ Two additional one-pole circuits available.
♦ Test button provides a means of confirming proper GFCI circuit breaker operation.
♦ 10,000 amps interrupting capacity.
♦ 120/240VAC Single Phase 3-wire
♦ Pre installed neutral and ground bars.
♦ Type 3R enclosure good for indoor or outdoor mounting.
♦ Interior deadfront provides protection from energized parts.
♦ Padlockable cover provides added security and safety.
♦ Audible alarm option factory or field installable.
♦ Can be used as a disconnect to turn the spa pump on and off.
♦ Main lug connections will accomodate a single #14 - 1/0 AWG conductor. 

Product Description
CEC Rule 68-086 (1) and (6) requires that a Ground Fault Circuit Interrupter, of a Class A Type, be installed not closer than 3m (10 feet) to a pool or spa water. In cases where a spa is
installed some distance from your main loadcentre it is often more convenient to locate this protection device in a small panel closer to the spa. Excessive cable lengths required to
connect directly back to a protection device in your main loadcentre may be more susceptible to insulation breakage and result in nuisance tripping of the breaker. The reduced distance
the owner must travel to reset a tripped circuit breaker in a localized spa panel may also be an excellent selling point for the owner.

Product Selection
Table 55. Two Pole Plug-In Type 3R Spa Panels
Catalogue Number

Breaker
Amperage (A)

Breaker Type

Enclosure Style

Audible Alarm

Height
(Inches / mm)

Width
(Inches / mm)

Depth
(Inches / mm)

CH30SPA

30

CH

Indoor/Outdoor Type 3R a

N

12 / 304.8

6.875 / 174.62

4.5 / 114.3

CH

Indoor/Outdoor Type 3R

a

CH30SPALARM

30

CH40SPA

40

Y

12 / 304.8

6.875 / 174.62

4.5 / 114.3

CH

Indoor/Outdoor Type 3R

a

N

12 / 304.8

6.875 / 174.62

4.5 / 114.3

40

CH

Indoor/Outdoor Type 3R

a

CH40SPALARM

Y

12 / 304.8

6.875 / 174.62

4.5 / 114.3

CH50SPA

50

CH

Indoor/Outdoor Type 3R

a

N

12 / 304.8

6.875 / 174.62

4.5 / 114.3

CH50SPALARM

50

CH

Indoor/Outdoor Type 3R a

Y

12 / 304.8

6.875 / 174.62

4.5 / 114.3

CH60SPA

60

CH

Indoor/Outdoor Type 3R

a

N

12 / 304.8

6.875 / 174.62

4.5 / 114.3

CH60SPALARM

60

CH

Indoor/Outdoor Type 3R a

Y

12 / 304.8

6.875 / 174.62

4.5 / 114.3

Table 56. Spa Panel Accessories
Catalogue Number

Description

CHSPALARM

Field installable Audible Alarm Kit (breaker & panel not included)

Enclosure

Hot Tub

10 Feet
(3048 mm)

Check national and local codes for compliance.

CEC Code Note

CEC Rule 68-086 (1) and (6) requires that a Ground Fault Circuit Interrupter, of a Class A Type, be installed not closer than 3m (10 feet) to a pool or spa water
a


Outdoor Loadcentres accommodate Type DS conduit hubs. Hubs not included. See page 11 for selection.
Refer to page 30 for Type CH ground fault circuit breaker accepted load conductor sizes.
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

43

Surge Suppression Products
Stage 1 & Stage 1 Type 2

Residential Surge Suppression Products
♦ Stage 1 and Stage 2 surge protection as well as Type 1 and Type 2 offering.
♦ Convenient in-panel mount unit for Type BR loadcentres.
♦ Knockout mount or surface mount CHSP design. DIN mount adapter for Type 1.
♦ Limited lifetime warranty on CHSP family.
♦ Dovetail clip together telephone and cable surge accessories for CHSPT2 design.
♦ Flush mount kit for CHSPT2 design knockout mounting.
♦ Type 1 & 2 surge supression product designed to meet UL 1449 3rd edition standard.

Product Description
Today’s homes are filled with increasing quantities of devices containing sensitive electronic components. These devices can easily be damaged by common power surges also some
times called line transients, spikes, or voltage impulses. Lighting strikes, utility grid switching, other users on the powerline, and internal surges from air conditioners and powers
tools are the most common sources these damaging line transients. To protect your investment it is recommended that a surge suppression device be installed. Surge protection can
be broken into two stages. Stage 1 protection is primary protection for your service entrance. This protection is typically installed inside or adjacent to a home’s service entrance
distribution panel. Stage 2 protection is secondary protection or protection at the point of use. For proper surge protection both a stage 1 and stage 2 device must be installed. Eaton
offers surge products to provide both levels of protection to your sensitive equipment as well as both Type 1 and Type 2 surge devices that meet the latest UL 1449 3rd standard. We
also offer surge protection devices for telephone, cable/satellite and ethernet protection since surges are not isolated to the utility lines only.

Product Selection
Table 57. Stage 1 (Point of service entrance) Residential Surge Suppression Products for Type BR Plug-In Loadcentres
Catalogue
Number

BRSURGE

Connection

Plug-On to loadcentre bus in
Type BR loadcentres.

Voltage
(Vac)

120/240

Phase

Frequency
(Hz)

Maximum Continuous
Operating Voltage a (V)

Voltage
Protection
Rating b

Nominal
Discharge
Current  (A)

Short Circuit
Current Rating

(A)

Surge Current
Capacity per
Phase  (A)

Single

60

200 Line to Neutral (L-N)
400 Line to Line (L-L)

600V L-N
1000V L-L

3,000

10,000

18,000

Table 58. Stage 1 Type 2 (Point of service entrance) Residential Surge Suppression Products for Any Loadcentre

Catalogue Number

Connection

CHSPT2MICRO

Can be attached to the outside
of any manufacturer’s loadcentre
(breaker box). This product
should be connected on the
load side of the loadcentre main
service disconnect through a
dedicated circuit breaker (follow
CEC Guidelines).

CHSPT2MAX
CHSPT2ULTRA
CHSPT23PACK 

Voltage
(Vac)

Voltage
Protection
Rating b

Nominal
Discharge
Current  (A)

Short Circuit
Current Rating

(A)

Surge Current
Capacity per
Phase  (A)

600V L-N
1000V L-L
800V N-G
600V L-G

5,000

22,000

36,000

10,000

22,000

72,000

60

20,000 

22,000

108,000

60

20,000 

22,000

108,000

Phase

Frequency
(Hz)

Maximum Continuous
Operating Voltage a (V)

120/240

Single

60

150 Line to Neutral (L-N)

120/240

Single

60

120/240

Single

120/240

Single

300 Line to Line (L-L)

	
	

Breaker Panel (CHSP)

Stage 2 Protection
  

Point-of-Use (SurgeTrap)
BRANCH
CIRCUITS

Maximum Continuous Operating Voltage that may be applied to the device per mode.
b
Voltage Protection Rating is the measured limiting voltage after a surge event.

Nominal Discharge Current is the current that the device can withstand for 15 impulses.

The amount of current the product can withstand under short circuit conditions.

The maximum one time surge current rating per phase.

When used with a 50A two-pole breaker, 10kA when used with a 15A two-pole breaker.

CHSPT23PACK contains one each of CHSPT2ULTRA, CHSPCABLE, and CHSPTELE.
a

44	

Stage 1 Protection
  

3

DEDICATED
BRANCH CIRCUIT

	

Accessories
  

Incoming Telephone/Cable Lines

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Surge Suppression Products
Stage 2 & Accessories

Residential Surge Suppression Products Continued
Table 59. Stage 2 (Point-of-use) Residential Surge Suppression Products

Application

AC
Outlets

Telephone
Outlets

Cable
Outlets

Cord
Length

Product
Warranty

Connected
Equipment
Warranty

Maximum Surge
Current (A) a

Total Joules
(Joules)

Entry Level

AC Power, Telephone/Modem

1

1

—

—

Lifetime

$50,000

36,000

540

SMICRO1C

Entry Level

AC Power, Cable TV

1

—

1

—

Lifetime

$50,000

36,000

540

SMICRO6T

Entry Level

AC Power, Telephone/Modem

6

1

—

—

Lifetime

$50,000

36,000

540

SMICRO6TC

Entry Level

AC Power, Telephone/Modem, Cable TV

6

1

1

—

Lifetime

$50,000

36,000

540

SMICRO7

Entry Level

AC Power

7

—

—

6ft

Lifetime

$50,000

36,000

540

SMAX7

Mid Level

AC Power

7

—

—

6ft

Lifetime

$75,000

72,000 - 144,000

1,080 - 2,160

SMAX7T

Mid Level

AC Power, Telephone/Modem

7

1

—

6ft

Lifetime

$75,000

72,000 - 144,000

1,080 - 2,160

SMAX7C

Mid Level

AC Power, Cable TV

7

—

1

6ft

Lifetime

$75,000

72,000 - 144,000

1,080 - 2,160

SMAX8TC

Mid Level

AC Power, Telephone/Modem, Cable TV

8

1

1

6ft

Lifetime

$75,000

72,000 - 144,000

1,080 - 2,160

SULT10TC

Advanced

1

1

6ft

Lifetime

$150,000

144,000 - 288,000

2,160 - 4,320

SULT12TC

Advanced

AC Power, Telephone/Modem, Cable TV, 10
DBS Satellite
12

1

1

6ft

Lifetime

$150,000

144,000 - 288,000

2,160 - 4,320

SULT8T

Advanced

AC Power, Telephone/Modem

8

1

—

6ft

Lifetime

$150,000

144,000 - 288,000

2,160 - 4,320

SCONST7

Heavy Duty

AC Power

7

—

—

6ft

Lifetime

N/A

72,000

1,080

POWER3

None

Power Strips

36

—

—

3ft

—

—

—

—

POWER5

None

Power Strips

6

—

—

5ft

Catalogue
Number

Protection
Level

SMICRO1T

Table 60. Residential Surge Suppression Accessories

Micro

Max

Ultra

Construction

Connected
Equipment
Warranty

Maximum Surge Current
(A) a

Catalogue Number

Description

Application

Product
Warranty

CHSPTELE

SurgeTel™

Telephone, modem, and DSL (4 lines)

Lifetime

$10,000

80,000

CHSPCABLE

SurgeCable™

Cable TV, satellite, cable modems (2 lines)

Lifetime

$10,000

20,000

CHSPFMKIT

Flushmount Kit™

Flush mount kit for finished wall installations

—

N/A

N/A

Installation
CHSP*

CHSP and accessories can be mounted on the side,
top, or bottom of a circuit breaker panel.
* CHSP MICRO, MAX, ULTRA or the 3 pack can
be used interchangeably depending on protection
SurgeCable™ required.

SurgeTel™

SurgeTel™

a

SurgeCable™

Maximum surge rating is the sum of all modes of protection.
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

45

Surge Suppression Products
Type 1

Type 1 Surge Protective Devices
♦ Commercial grade AC power protection.
♦ Type 1 surge device for installation before or after the main service disconnect.
♦ Universal fit to any manufacturer’s equipment.
♦ Clear visible LED indication displaying status of surge protector.
♦ Optional accessory kit enables wall or DIN-rail mounting (SP1DINRAILKIT).
♦ Suitable for indoor or outdoor applications.
♦ Can be used as a replacment for what was previously known as secondary surge arrestors or lightning arrestors.

Table 61. Type 1 Surge Protective Devices for Service Entrance Surge Protection of Any Loadcentre - UL 1449 3rd Edition
Compliant

Phase

Frequency
(Hz)

Maximum Continuous
Operating Voltage a (V)

Voltage
Protection
Rating b

Nominal
Discharge
Current  (A)

Short Circuit
Current Rating

(A)

Surge Current
Capacity per
Phase  (A)

100/200
110/220
120/240

Single

50/60

150 Line to Neutral (L-N)
300 Line to Line (L-L)

600V L-N
1000V L-L

20,000

200,000

36,000

100/200
110/220
120/240

Single

50/60

150 Line to Neutral (L-N)
300 Line to Line (L-L)

600V L-N
1000V L-L

20,000

200,000

45,000

CHSPT1ULTRA

100/200
110/220
120/240

Single

50/60

150 Line to Neutral (L-N)
300 Line to Line (L-L)

600V L-N
1000V L-L

20,000

200,000

50,000

CHSPT1-208Y

100/200
110/220
120/240

ThreePhase
WYE

50/60

150 Line to Neutral (L-N)
300 Line to Line (L-L)

600V L-N
1000V L-L

20,000

200,000

50,000

Catalogue Number

Connection

CHSPT1MICRO

Permanently connected device
installed before or after the
service disconnect overcurrent
device. (follow CEC Guidelines
for connection).

CHSPT1MAX

Voltage
(Vac)

Maximum Continuous Operating Voltage that may be applied to the device per mode.
Voltage Protection Rating is the measured limiting voltage after a surge event.

Nominal Discharge Current is the current that the device can withstand for 15 impulses.

The amount of current the product can withstand under short circuit conditions.

The maximum one time surge current rating per phase.
a
b

46	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Street Lighting Panels
In-Pole

Service Entrance Approved Street and Roadway Lighting Panels
♦ Compact in-pole panel fits into lighting pole hand well.
♦ Pole mount 3R (rain-tight) street lighting panels can be mounted right onto the pole.
♦ Pedestal mount 3R (rain-tight) street lighting panels feature a Eaton loadcentre housed in a Pencell enclosure.

Product Description
Since January 1, 2003 the Ontario Electric Safety Code requires that all roadway lighting shall meet the service entrance requirements of Rule 30-1002. Eaton has developed several
designs of approved products to suit the various installation points (pole mounted, within an enclosure etc). All products are CSA approved.

In-Pole Street Lighting Panels
♦ Fits into most pole manufacturers’ hand well.
♦ Service entrance approved.
♦ 3R Rain-tight.
♦ Pre-wired.
♦ Single pole or 2-pole 22kA 50A versions.
♦ Removable mounting plates accommodate multiple hand wells.
♦ CSA Approved.
♦ Approximate dimensions 9” x 2-1/4” x 4”.
♦ Line power connections via #6 AWG conductor pigtail.
♦ Load power connections via #14 AWG conductor pigtail.
♦ #6 AWG Conductor pigtail provided for daisy chaining of additional light poles.

Product Selection
Table 62. In-Pole Street Lighting Panels
Catalogue Number

Voltage (V)

Main Circuit Breaker

Interrupting
(kAIC)

1SL150PCO

120Vac In-Pole Compact Street Lighting Panel

120Vac

Single Pole 15A

22

1SL300PCO

120V In-Pole Compact Street Lightning Panel

120Vac

Single Pole 30A

22

1SL500PCO

120Vac In-Pole Compact Street Lighting Panel

120Vac

Single Pole 50A

22

2SL150PCO

240Vac In-Pole Compact Street Lighting Panel

120/240Vac

Two Pole 15A

22

2SL300PCO

240Vac In-Pole Compact Street Lighting Panel

120/240Vac

Two Pole 30A

22

2SL500PCO

240Vac In-Pole Compact Street Lighting Panel

120/240Vac

Two Pole 50A

22

	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

47

Street Lighting Panels
On-Pole

Service Entrance Approved Street and Roadway Lighting Panels Continued
On-Pole Street Lighting Panels
♦ Mounts directly onto the pole.
♦ Strap mount version includes slots in the enclosure back to allow for strap mounting.
♦ Two extra 1” breaker locations that accept type BR and DNPL plug-in circuit breakers for additional lighting loads.
♦ Service entrance approved.
♦ 3R Rain-tight.
♦ Single pole or 2-pole 22kA 50, 60, or 70A versions.
♦ CSA Approved.
♦ Approximate dimensions 13” x 11” x 4-1/2”.
♦ Bottom entry service entrance cabling only.

Product Selection
Table 63. On-Pole Street Lighting Panels Standard Mount

Catalogue Number

Voltage (V)

Main Circuit Breaker

Interrupting (kAIC)

Branch Circuits (1”/½”)

Main Circuit Breaker
Wire Size Range
(Cu/AL 60ºC or 75ºC) (AWG)

1SL502

120

Single Pole 50A

22

2/4

#14 - 4

1SL602

120

Single Pole 60A

22

2/4

#4 - 1/0

1SL702

120

Single Pole 70A

22

2/4

#4 - 1/0

2SL502

120/240

Two Pole 50A

22

2/4

#14 - 4

2SL602

120/240

Two Pole 60A

22

2/4

#4 - 1/0

2SL702

120/240

Two Pole 70A

22

2/4

#4 - 1/0

Product Selection
Table 64. On-Pole Street Lighting Panels Strap Mount

Catalogue Number

Voltage (V)

Main Circuit Breaker

Interrupting (kAIC)

Branch Circuits (1”/½”)

Main Circuit Breaker
Wire Size Range
(Cu/AL 60ºC or 75ºC) (AWG)

1SL502S

120

Single Pole 50A

22

2/4

#14 - 4

1SL602S

120

Single Pole 60A

22

2/4

#4 - 1/0

1SL702S

120

Single Pole 70A

22

2/4

#4 - 1/0

2SL502S

120/240

Two Pole 50A

22

2/4

#14 - 4

2SL602S

120/240

Two Pole 60A

22

2/4

#4 - 1/0

2SL702S

120/240

Two Pole 70A

22

2/4

#4 - 1/0

2SL706S

120/240

Two Pole 70A

22

6 / 12

#4 - 1/0

48	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Street Lighting Panels
Pedestal

Service Entrance Approved Street and Roadway Lighting Panels Continued
Pedestal Mounted Street Lighting Panels
♦ Lightweight, stand-alone units mount on the ground.
♦ Polyethylene Pencell enclosure provides rugged, Low profile, rain-tight assembly.
♦ Penta head and key lock provision for security.
♦ Vented or non-vented enclosure styles..
♦ Two extra 1” breaker locations accept type BR and DNPL plug-in circuit breakers for additional lighting loads.
♦ Service entrance approved.
♦ 3R Rain-tight.
♦ Single pole or 2-pole 22kA 50, 60, or 70A versions.
♦ CSA Approved.
♦ Underground duct or direct burial cable accessible.

Non-Vented

Product Selection
Table 65. Pedestal Mount Non-Vented Street Lighting Panels
Catalogue Number

Voltage (V)

Main Circuit Breaker

Interrupting (kAIC)

Branch Circuits (1”/½”)

Extension

Main Circuit Breaker Wire Size Range
(Cu/AL 60ºC or 75ºC) (AWG)

1SL502NV

120

Single Pole 50A

22

2/4

No

#14 - 4

1SL602NV

120

Single Pole 60A

22

2/4

No

#4 - 1/0

1SL702NV

120

Single Pole 70A

22

2/4

No

#4 - 1/0

2SL502NV

120/240

Two Pole 50A

22

2/4

No

#14 - 4

2SL602NV

120/240

Two Pole 60A

22

2/4

No

#4 - 1/0

2SL702NV

120/240

Tow Pole 70A

22

2/4

No

#4 - 1/0

1SL502NVE

120

Single Pole 50A

22

2/4

Yes

#14 - 4

1SL602NVE

120

Single Pole 60A

22

2/4

Yes

#4 - 1/0

1SL702NVE

120

Single Pole 70A

22

2/4

Yes

#4 - 1/0

2SL502NVE

120/240

Two Pole 50A

22

2/4

Yes

#14 - 4

2SL602NVE

120/240

Two Pole 60A

22

2/4

Yes

#4 - 1/0

2SL702NVE

120/240

Tow Pole 70A

22

2/4

Yes

#4 - 1/0

Product Selection
Table 66. Pedestal Mount Vented Street Lighting Panels

Catalogue Number

Voltage (V)

Main Circuit Breaker

Interrupting (kAIC)

Branch
Circuits
(1”/½”)

1SL502VE

120

Single Pole 50A

22

2/4

Yes

#14 - 4

1SL602VE

120

Single Pole 60A

22

2/4

Yes

#4 - 1/0

1SL702VE

120

Single Pole 70A

22

2/4

Yes

#4 - 1/0

2SL502VE

120/240

Two Pole 50A

22

2/4

Yes

#14 - 4

2SL602VE

120/240

Two Pole 60A

22

2/4

Yes

#4 - 1/0

2SL702VE

120/240

Tow Pole 70A

22

2/4

Yes

#4 - 1/0

Extension

Main Circuit Breaker Wire Size Range
(Cu/AL 60ºC or 75ºC) (AWG)

Vented

	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

49

Combined Loadcentre and Meter Socket

Combined Loadcentre and Meter Socket
♦ 4 Jaw, 100 and 200A, 120/240V 22kAIC.
♦ Service entrance rated with 100 or 200A main circuit breaker included.
♦ Suitable for underground or overhead service entrance.
♦ Meter socket mechanical lugs accommodate #6-250MCM Cu/Al line conductors and (2) #6-300MCM Cu/Al neutral conductors.
♦ Loadcentre mechanical lugs load and neutral (2) #6-300MCM Cu/Al.
♦ CSR circuit breaker mechanical load lugs #2-300MCM.
♦ Suitable for over head or under ground service entrance.
♦ Suitable applications include farming, temporary service, construction sites, trailers, and mobile homes.
♦ Hub opening and plate included. Hubs ordered separately (use DS type hubs)
♦ 3R Enclosure
♦ CSA Approved

Product Selection
Table 67. Combined Loadcentre and Meter Socket
Catalogue Number

Enclosure

Voltage
(V)

Amperage
(A)

Interrupting
(kAIC)

Entrance Type

Branch
Circuits
(1”/½”)

Weight (lbs
/ kg)

Dimensions (In / mm)

RCPM108M

Indoor/Outdoor Type 3R

120/240

100

22

Underground/Overhead

8/16

36.5 / 16.6

28-3/8 x 14-7/16 x 5-3/8
974.7 x 366.7 x 136.5

RCPM208M

Indoor/Outdoor Type 3R

120/240

200

22

Underground/Overhead

8/16

36.5 / 16.6

28-3/8 x 14-7/16 x 5-3/8
974.7 x 366.7 x 136.5

Table 68. Knockout Legend
Location

Knockout Size (Inches (mm))

Quantity

Bottom End Wall

.50 (12.7)

7

Bottom End Wall

.50, .75 (12.7, 19.1)

4

Bottom End Wall

.50, .75, 1.00 (12.7, 19.1, 25.4)

1

Bottom End Wall

1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8)

1

Bottom End Wall

1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2)

1

Top End Wall

Provision for Huba (e.g. DS200H2, DS250H2, DS300H2)

2

Backplane

1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5)

1

Backplane

1.25, 1.50, 2.00 (31.8, 38.1, 50.8)

1

Right Sidewall

1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5)

1

a

Accommodate Type DS conduit hubs. Hubs not included. See Page 11 for selection.

50	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Metered Temporary Ground Fault Power Panel

Metered Temporary Power Panel with Ground Fault Protection
♦ Combination loadcentre, meter socket, and electrical outlets for temporary work site installations.
♦ Single phase 3 wire
♦ 4 Jaw, 100 or 200A, 120/240V 22kAIC meter socket.
♦ Suitable for over head or under ground service entrance.
♦ CSA approved for service entrance.
♦ 3R Enclosure suitable for outdoor installations.
♦ Two different receptacle combinations 6X20A and 2X30A or 10X20A.
♦ Hub opening and plate included. Hubs ordered separately (uses DS type hubs).
♦ Meter socket mechanical lugs accommodate #6-250MCM Cu/Al line conductors and #6-300MCM Cu/Al neutral conductors.

Product Selection
Table 69. Metered Temporary Ground Fault Protected Power Panel
Catalogue Number

Enclosure

Voltage
(V)

Amperage
(A)

Interrupting
(kAIC)

Entrance Type

20A
Receptacles

30A
Receptacles

RCPM1GF6H

Indoor/Outdoor Type 3R

120/240

100

22

Underground/Overhead

6

2

34-3/8 x 22 x 5-3/8
873.1 x 558.8 x 136.5

RCPM1GF10

Indoor/Outdoor Type 3R

120/240

100

22

Underground/Overhead

10

0

34-3/8 x 22 x 5-3/8
873.1 x 558.8 x 136.5

RCPM2GF6H

Indoor/Outdoor Type 3R

120/240

200

22

Underground/Overhead

6

2

34-3/8 x 22 x 5-3/8
873.1 x 558.8 x 136.5

RCPM2GF10

Indoor/Outdoor Type 3R

120/240

200

22

Underground/Overhead

10

0

34-3/8 x 22 x 5-3/8
873.1 x 558.8 x 136.5

Dimensions (In / mm)

Table 70. Knockout Legend
Catalogue Number

Knockout Size (in)

Quantity

Bottom Endwall

1/2, 3/4

6

Bottom Endwall

1/2, 3/4, 1, 1-1/4

2

Bottom Endwall

1, 1-1/4, 1-1/2, 2, 2-1/2

1

Bottom Endwall

1, 1-1/4, 1-1/2, 2, 2-1/2, 3

1

Top Endwall

Provision for Hub (e.g. DS200H2, DS250H2, DS300H2)

1

a

a

Accommodate Type DS conduit hubs. Hubs not included. See Page 11 for selection.
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

51

Mini-Power Centres

Mini-Power Centres
♦ Distribution transformer, breaker protection, and loadcentre all in one compact package.
♦ Primary and secondary breaker protection via factory installed EHD or FDB type MCCBs.
♦ 18, 25, or 35kAIC Interrupting capacity versions available on select models through special order.
♦ Two styles of interior; one for plug-in or bolt-on (breakers not included).
♦ Loadcentre accommodates up to 24 feeder circuit breakers. (Breakers purchased separately)
♦ Aluminum chassis on plug-in type, copper chassis on bolt-on type, standard ground bar, and enclosure grounded

neutral bar.
♦ All live parts are enclosed.
♦ Hinged, padlockable cover prevents removal.
♦ Enclosure includes grounding terminal.
♦ Type 3R enclosure with baked polymer polyester powder coating is good for indoor or outdoor mounting.
♦ Optional type 3R, 316 grade stainless steel enclosure.
♦ Main circuit breaker barrier provides CSA approval for service entrance applications.
♦ Electrical grade aluminum windings standard on the distribution transformer (copper optional).
♦ Copper windings standard on bolt-on style units.
♦ 185°C Insulation system.
♦ 115°C Winding temperature rise.
♦ Full capacity taps (FCBN) 2-5%.
♦ Resin encapsulated, core-coil assembly (cores grounded with copper lead).

Product Description
Contemporary electrical distribution systems are required to do more in less space while at the same time being cost-effective. Eaton provides a solution to these
requirements with the proven Mini-Power Centre. It occupies considerably less space and can save up to 31 percent of the installation costs normally required when
individual components are used. The solution is possible because a Mini-Power Centre combines three individual components into one NEMA Type 3R enclosure: a main
breaker, an encapsulated Type EP or EPT Dry-Type Transformer, and a secondary distribution loadcentre with main breaker. Interconnecting wiring is completed at the
factory. A Mini-Power Centre is delivered ready for installation. It’s suitable for use as service entrance equipment, too. Mini-Power Centres are used wherever there is a
480V or 600V distribution system and loads requiring 208Y/120V three-phase or 120/240V single-phase.
Typical installations include:
♦Industrial plant assembly lines

♦ Plant expansions

♦ Commercial buildings

♦Test equipment

♦ Temporary power at construction sites

♦ Sewage disposal plants

♦Warehouses

♦ Car washes

♦ Parking lots
Mini-Power Centre	
Normal Layout	
15kVA, Three-Phase 15kVA, Three-Phase

The Mini-Power Centre saves you space, time, and money.
A Mini-Power Centre installation takes up only 42% of the space taken
up by a typical installation. A typical installation being comprised of
a separately mounted distribution transformer, disconnect switch,
loadcentre and all associated wiring and connectors.

Fused
Switch

Loadcentre
15 kVA
3-Phase
Transformer

72" Wide

The installation costs of a Mini-Power Centre are 31% less when compared
with the same typical installation.
Time To Perform Task(s) a (Hours)
15kVA

15kVA

25kVA

25kVA

Installation

Typical Installation

Mini-Power Centre Installation

Typical Installation

Mini-Power Centre Installation

Switch & Fuse Mounting

5

0

5

0

Transformer Layout (remove knockout, etc.)

16

16

24

24

Fasten Transformer to wall

4

0

4

0

Layout Loadcentre, mount and connect source

4

4

6

4

Total Hours:

29

20

39

28

% Time Saved by using a Eaton Mini-Power Centre:

a

31%

28%

Time estimates are typical and will vary according to geographical area.

52	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Plug-In Mini-Power Centres
Plug-In

Product Selection
Table 71. Single Phase Plug-In Mini-Power Centres
Main Circuit Breaker 

Maximum Number of Feeder
Circuit Breakers

Primary

Secondary

1-Pole

2-Pole

3-Pole

Maximum
Amperage

P48G11S03P

EHD2015

BR215

8

4

-

480 to 120/240

P48G11S05P

EHD2020

BR225

12

6

480 to 120/240

P48G11S07P

EHD2030

BR230

12

6

10

480 to 120/240

P48G11S10P

EHD2040

BR250

12

15

480 to 120/240

P48G11S15P

EHD2060

BR270

25

480 to 120/240

P48G11S25P

EHD2100

BR2125

5

600 to 120/240

P60G11S05P

FDB2015

7.5

600 to 120/240

P60G11S07P

FDB2030

10

600 to 120/240

P60G11S10P

15

600 to 120/240

25

600 to 120/240

kVA

Primary &
Secondary Voltage
(V)

Catalogue Number

3

480 to 120/240

5
7.5

Dimensions b (Inches / mm)
Height

Width

Depth

Weight (lbs
/ kg)

12

27.5 / 699

12.6 / 320

105 / 47

105 / 47

-

20

29.5 / 749

12.6 / 320

105 / 47

105 / 47

-

30

29.5 / 749

12.6 / 320

125 / 56

125 / 56

6

-

40

38.2 / 970

13.5 / 343

177 / 80

177 / 80

20

10

-

60

38.2 / 970

13.5 / 343

212 / 96

212 / 96

26

13

-

100

43.9 / 1115

16.4 / 417

373 / 169

373 / 169

BR225

12

6

-

20

29.5 / 749

12.6 / 320

105 / 47

105 / 47

BR230

12

6

-

30

29.5 / 749

12.6 / 320

125 / 56

125 / 56

FDB2040

BR250

12

6

-

40

38.2 / 970

13.5 / 343

177 / 80

177 / 80

P60G11S15P

FDB2060

BR270

20

10

-

60

38.2 / 970

13.5 / 343

212 / 96

212 / 96

P60G11S25P

FDB2100

BR2125

26

13

-

100

43.9 / 1115

16.4 / 417

373 / 169

373 / 169

a

Table 72. Three Phase Plug-In Mini-Power Centres
Main Circuit Breaker 

Maximum Number of Feeder
Circuit Breakers

Primary

Secondary

1-Pole

2-Pole

P48G28T15P

EHD3040

BR350

18

P48G28T21P

EHD3070

BR370

18

480 to 120/208

P48G28T30P

EHD3090

BR3100

600 to 120/208

P60G28T15P

FDB3030

BR350

22.5

600 to 120/208

P60G28T21P

FDB3050

30

600 to 120/208

P60G28T30P

FDB3070

kVA

Primary &
Secondary Voltage
(V)

Catalogue Number

15

480 to 120/208

22.5

480 to 120/208

30
15

a

Dimensions b (Inches / mm)

3-Pole

Maximum
Amperage

Height

Width

Depth

Weight (lbs
/ kg)

9

6

40

36.1 / 917

28.8 / 732

320 / 145

320 / 145

9

6

60

40.9 / 1039

29.9 / 759

565 / 256

565 / 256

24

12

8

80

41.9 / 1064

29.9 / 759

635 / 288

635 / 288

18

9

6

40

36.1 / 917

28.8 / 732

320 / 145

320 / 145

BR370

18

9

6

60

40.9 / 1039

29.9 / 759

565 / 256

565 / 256

BR3100

24

12

8

80

41.9 / 1064

29.9 / 759

635 / 288

635 / 288

For a primary main circuit breaker interrupting capacity greater than 10kAIC add the following suffixes to the catalogue number; for 18kAIC add “F”, for 25kAIC add “H”, and for 35kAIC add “C”.
Not for construction purposes.

Main circuit breakers fixed only. No substitutes.

Feeder circuit breakers not included. Uses Eaton Type BR circuit breakers.
Note: For price and delivery on a unit with copper transformer windings or 316 grade stainless steel enclosure contact your local Eaton sales representative or our Customer Service centre at 1-800-268-3578.
a
b

	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

53

Bolt-On Mini-Power Centres
Bolt-On

Product Selection
Table 73. Single Phase Bolt-On Mini-Power Centres
Main Circuit Breaker b

Maximum Number of Feeder
Circuit Breakers  

Catalogue Number

Primary

Secondary

1-Pole

2-Pole

3-Pole

Maximum
Amperage

480 to 120/240

P48G11S03CUB

EHD2015L

BAB2015

12

6

-

480 to 120/240

P48G11S05CUB

EHD2020L

BAB2025

18

9

-

7.5

480 to 120/240

P48G11S07CUB

EHD2030L

BAB2030

18

9

10

480 to 120/240

P48G11S10CUB

EHD2040L

BAB2050

18

9

15

480 to 120/240

P48G11S15CUB

EHD2060L

BAB2070

24

25

480 to 120/240

P48G11S25CUB

EHD2100L

BAB2125

3

600 to 120/240

P60G11S03CUB

FDB2015L

BAB2015

5

600 to 120/240

P60G11S05CUB

FDB2020L

7.5

600 to 120/240

P60G11S07CUB

FDB2030L

10

600 to 120/240

P60G11S10CUB

15

600 to 120/240

25

600 to 120/240

kVA

Primary &
Secondary Voltage
(V)

3
5

Dimensions  (Inches / mm)
Height

Width

Depth

Weight (lbs
/ kg)

12

33.2 / 845

12.6 / 320

9.7 / 245

105 / 47

20

36.1 / 918

12.6 / 320

9.7 / 245

110 / 50

-

30

36.1 / 918

12.6 / 320

9.7 / 245

110 / 50

-

40

40.9 / 1038

13.5 / 343

11.8 / 300

180 / 82

12

-

60

43.9 / 1115

15 / 380

11.8 / 300

215 / 98

30

15

-

100

43.4 / 1102

20.4 / 518

14.6 / 370

385 / 175

12

6

12

33.2 / 845

12.6 / 320

9.7 / 245

105 / 47

BAB2025

18

9

-

20

36.1 / 918

12.6 / 320

9.7 / 245

110 / 50

BAB2030

18

9

-

30

36.1 / 918

12.6 / 320

9.7 / 245

110 / 50

FDB2040L

BAB2050

18

9

-

40

40.9 / 1038

13.5 / 343

11.8 / 300

180 / 82

P60G11S15CUB

FDB2060L

BAB2070

24

12

-

60

43.9 / 1115

15 / 380

11.8 / 300

215 / 98

P60G11S25CUB

FDB2100L

BAB2125

30

15

-

100

43.4 / 1102

20.4 / 518

14.6 / 370

385 / 175

Table 74. Three Phase Bolt-On Mini-Power Centres
Main Circuit Breaker b

Maximum Number of Feeder
Circuit Breakers  

Catalogue Number

Primary

Secondary

1-Pole

2-Pole

3-Pole

Maximum
Amperage

480 to 120/208

P48G28T15CUB

EHD3040L

BAB3050H

18

9

6

22.5

480 to 120/208

P48G28T21CUB

EHD3070L

BAB3070H

18

9

30

480 to 120/208

P48G28T30CUB

EHD3090L

BAB3100H

24

12

15

600 to 120/208

P60G28T15CUB

FDB3030

BAB3050H

18

22.5

600 to 120/208

P60G28T21CUB

FDB3050

BAB3070H

18

30

600 to 120/208

P60G28T30CUB

FDB3070

BAB3100H

24

kVA

Primary &
Secondary Voltage
(V)

15

Dimensions  (Inches / mm)
Height

Width

Depth

Weight (lbs
/ kg)

40

36.1 / 917

28.7 / 730

9.4 / 238

320 / 148

6

60

40.9 / 1038

29.9 / 759

13.6 / 346

565 / 257

8

80

41.9 / 1063

29.9 / 759

13.6 / 346

635 / 288

9

6

40

36.1 / 917

28.7 / 730

9.4 / 238

320 / 148

9

6

60

40.9 / 1038

29.9 / 759

13.6 / 346

565 / 257

12

8

80

41.9 / 1063

29.9 / 759

13.6 / 346

635 / 288

Not for construction purposes.
Main circuit breakers fixed only. No substitutes.

Feeder circuit breakers not included. Uses Eaton Type BAB circuit breakers.

Combinations can be selected.
a
b

54	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Residential Fuse Panel Inserts

Residential Fuse Panel Inserts

a

♦ Convenient and economical option to completely replacing an entire fuse panel assembly.
♦ Original fuse panel tub and wiring remains in place and only the fuse panel trim and interior is removed and replaced.
♦ 16 and 24 circuit breaker interiors designed to fit any manufacturers’ fuse panel or discontinued design circuit breaker panel.
♦ Custom trim and door oversized to ensure fit with existing tub.
♦ Circuit breaker interior replacement eliminates the possibility of improperly sized amperage protection.
♦ No more loose fuses causing arcing and damage to the panel or wiring.
♦ CSA certified to mount into any existing box under file LL264-222.
♦ Can be mounted in any orientation as defined by the existing fuse panel tub orientation.
♦ Accepts plug-in type BR, DNPL, or GFCB circuit breakers. (Circuit breakers sold separately. Refer to pages 13 - 16 for selection)
♦ Trim comes complete with hinged door, non-locking spring latch, clear plastic card holder, and circuit directory card.
♦ Tin plated aluminum bus bars.

Product Description
Fuses and Fuse Panels were designed decades ago, to prevent the overload of circuit wiring that could lead to fires caused by overloaded electrical circuit
connections and / or short circuits. Records show however, that problems of fire and smoke inhalation are the more serious causes of death or injury.
Since early 1960’s, technology has allowed a tremendous increase in the number and use of appliances, tools, and control systems, many of which are
automatically controlled and cycle on and off. We now know that a cycling load will actually cause a plug (screw-on-type) fuse to loosen in its holder (that explains
why you can always find one or two fuses that can be tightened a quarter turn). Loose connections such as these develop heat, and in turn increase the risk of fire.
Small overloads can be absorbed by the margin of safety built into CSA certified devices. However, prolonged overloads or loose fuses will cause arcing and
ultimately, melting of the connections in either the panel or wiring, wherever the weakest link may be.
Eaton has designed a low cost method of replacing Fuse Panels with modern Circuit Breaker Panels. This method eliminates the need for cutting, re-plastering and
repainting the walls around the old panel.
Another risk with the old fuse panel design was the ease with which incorrect fuses could be used or changed without realization of the risks involved.
To eliminate these potential hazards Eaton has a new circuit breaker interior and trim kit that will quickly upgrade the existing installation to today’s electrical
standards and needs. An average upgrade takes one hour and thus creates the minimum of inconvenience to the homeowner/occupant.

Sample Specification
•	 Supply and install a new circuit breaker interior to replace existing plug fuse panel interior or out of date circuit breaker interior in each apartment or
condominium.
•	 Interior to be 16 or 24 circuit, rated 100A and 120/240V, designed in a single row breaker arrangement for fitting into existing recessed electrical panels.
•	 Supply and install new Trim & Door Assembly slightly larger then discarded fuse trim to minimize any requirements for patching or repainting.
•	 Bus bars shall be tin plated aluminum suitable for plug-in circuit breakers.
•	 Supply and install a Trim and Door Assembly with latch, to protect the circuit breaker toggle handles.
•	 Inserts must be CSA certified for mounting in any position, for ease in connecting to existing wiring.
•	 Install circuit breakers with ratings as indicated in specifications or drawings.
•	 Interiors to be mounted with directions template and hardware supplied by Eaton.
•	 Inserts, Trim & Door Assembly and circuit breakers, shall be manufactured by Eaton.
•	 Provide a Circuit Identification Card, mounted under clear plastic on the inside of the door.

a

Not for use as service entrance equipment..
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

55

Residential Fuse Panel Inserts
Insert Interiors

Residential Fuse Panel Insert Interiors
♦ 100A Single phase 3 wire 120/240VAC.
♦ 16 and 24 circuit breaker capacity. 
♦ CSA certified to mount into any existing box under file LL264-222.
♦ Accepts plug-in type BR and DNPL circuit breakers. a 
♦ Tin plated aluminum bus bars.
♦ Neutral available with 16 or 24 Cu/Al terminals.
♦ Main and neutral lugs located at the same end.
♦ All terminals accept #14-3AWG cabling.

Product Selection
Table 75. 3 Wire 120/240VAC Fuse Panel Insert Interiors
Number of Installable Circuit Breakers

Catalogue Number

Drilling Template
Catalogue Number 

Amperage Rating
(A)

Voltage (V)

1” Spaces

1/2” Spaces

Bus Material

Neutral
Material

Wire Size Range Cu/Al

CQLP8100

CSABP4683B

100

120/240

8

16

Aluminum

Aluminum

#14-3 AWG

CQLP12100

CSABP4734B

100

120/240

12

24

Aluminum

Aluminum

#14-3 AWG

Refer to pages 13-16 for plug-in circuit breaker selection.
We suggest the use of templates to ensure proper sizing for installation.

Filler plates for unused fuse panel insert circuit breaker installation locations can be ordered as BRFP (package of 24).
a


56	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Residential Fuse Panel Inserts
Trims

Residential Fuse Panel Insert Trims
♦ Doors are die formed with sloping sides and rounded corners and permanently mounted to the trim.
♦ Semi concealed hinges. a
♦ Includes circuit directory card and self adhesive clear plastic directory holder.
♦ Painted ASA61 light grey baked on enamel.
♦ Mounting hardware included. 
♦ Trims are custom sized larger than the existing trim and door.
♦ Mounting holes located to line up with existing box holes. b

Product Selection
Table 76. Fuse Panel Insert Trims
Original Manufacturer

Fuse Panel
Catalogue Number

Amalgamated
Amalgamated

Box Dimensions
Height

Width

Depth

Replacement Trim
Catalogue Number

4112

16-1/8

8-1/2

2-15/16

4116

19-1/2

8-1/2

2-15/16

Amalgamated

4120

22-7/8

8-1/2

Amalgamated

4208

16-1/8

8-1/2

Amalgamated

4212

19-1/2

Amalgamated

4216

22-7/8

Amalgamated

4220

Amalgamated
CEB

Trim Size (Inches)
Height

Width

Replacement Interior
Catalogue Number

QLPT16D

18-1/4

9-3/4

QLPT19D

20-7/8

9-3/4

2-15/16

QLPT22AD

25

10-1/2

CQLP12100

2-15/16

QLPT16AD

18-1/4

10-5/16

CQLP8100

8-1/2

2-15/16

QLPT20AD

20-7/8

9-3/4

8-1/2

2-15/16

QLPT22AD

25

10-1/2

24-1/8

8-1/2

2-15/16

QLPT24D

26

4312

22-7/8

8-1/2

2-15/16

QLPT22AD

NHP10-636-3 

24

10

3

QLPT24LD

CEB

NHP12-60

20

7-3/4

3

CEB

NHP12-633

23

7-3/4

3

CEB

NHP4-632

16-1/4

7-3/4

CEB

NHP6-633

20

CEB

NHP6-636-4

24

CEB

NHP8-60

CEB

NHP8-635-3

Taylor (CrouseHinds)
Taylor (CrouseHinds)

Trim Mounting Holes (Inches)
Height

Width

CQLP8100

16-1/6

4

CQLP8100

18-11/16

4

22-1/4

6

15-1/2

6

CQLP8100

18-11/16

6

CQLP12100 

22-1/4

6

9-3/4

CQLP12100



23-13/16

4

25

10-1/2

CQLP12100



22-1/4

6

26

12

CQLP12100 

23-13/16

4

QLPT20D

21-3/4

9-3/4

CQLP12100

19-9/16

4

QLPT24D

26

9-3/4

CQLP12100 

23-13/16

4

3

QLPT16D

18-1/4

9-3/4

CQLP8100

16-1/6

4

7-3/4

3

QLPT19D

20-7/8

9-3/4

CQLP8100

18-11/16

4

7-3/4

3

QLPT24D

26

9-3/4

CQLP12100 

23-13/16

4

16-1/8

7-3/4

3

QLPT16D

18-1/4

9-3/4

CQLP8100

16-1/6

4

23

7-3/4

3

QLPT24D

26

9-3/4

CQLP12100 

23-13/16

4

NHP6-30-60

21

7-3/8

3

QLPT20D

21-3/4

9-3/4

CQLP12100

19-9/16

4

NHP20-1231

24-1/2

9-1/2

3

QLPT24D

26

9-3/4

CQLP12100 

23-13/16

4

Taylor (CrouseHinds)

NHP20-0821-6

24-1/2

9-1/2

3

QLPT24D

26

9-3/4

CQLP12100

23-13/16

4

Taylor (CrouseHinds)

NHP12B-1000-2

17-1/8

9-1/2

3

QLPT16AD

18-1/8

10-5/16

CQLP8100

15-1/2

6

Taylor (CrouseHinds)

NHP10-0401-4

17-1/8

9-1/2

3

QLPT16AD

18-1/8

10-5/16

CQLP8100

15-1/2

6

Taylor (CrouseHinds)

NHP10-0601-2

17-1/8

9-1/2

3

QLPT16AD

18-1/8

10-5/16

CQLP8100

15-1/2

6

Taylor (CrouseHinds)

NHP10-0611

17-1/8

9-1/2

3

QLPT16AD

18-1/8

10-5/16

CQLP8100

15-1/2

6

Taylor (CrouseHinds)

NHP10-0801

17-1/8

9-1/2

3

QLPT16AD

18-1/8

10-5/16

CQLP8100

Taylor (CrouseHinds)

NHP12-0811

19-1/4

9-1/2

3

QLPT22AD

25

Taylor (CrouseHinds)

NHP14-0801-4

19-1/4

9-1/2

3

QLPT22AD

25

Taylor (CrouseHinds)

NHP14-0621-2

19-1/4

9-1/2

3

QLPT22AD

25









15-1/2

6

10-1/2

CQLP12100



22-1/4

6

10-1/2

CQLP12100 

22-1/4

6

10-1/2

CQLP12100

22-1/4

6



If the main service entrance is bottom entry the door hinges left. If it is top entry then the door hinges right.
Measure the existing box holes locations as they may be part of the end walls, side walls, or tapped into a box flange.

The hardware supplied will accommodate boxes that are mounted up to 1/2” too deep or equal to 3-1/2” net depth.

Panel insert CQLP8100 can also be used with this size trim.

For box sizes either 26” or 27-1/2” high no insert or trim is available..
a
b

	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

57

Residential Fuse Panel Inserts
Data Information Form

Residential Fuse Panel Insert Data Information Form
(Required to replace a Plug Fuse Panel, with a Circuit Breaker Interior, and retain the existing Fuse Box).

Project______________________________________________________________ Location___________________________________________________
Engineer_ ___________________________________________________________________Existing Catalogue Number______________________________

Manufacturer
Canadian Electric Box and Stamping
CEB Ltd.
Sylvania
Amalgamated
Taylor
Crouse-Hinds

Inside Box

p	
p	
p	
p	
p	
p	
p	

________________

Mains Capacity
Mains Cable Type

p 100A or ____________
p Copper p Aluminum

Main Cable Gauge #8
Branch Cable Type

#6

#4

#3

p Copper p

#2

(if identifiable)

Aluminum

Up Stream Protection
Circuit Breakers
Fused Switches
Every Floor	

	
	

p 50A p 60A p 70A p 100A
p 60A p 100A
p Every third floor

Flanged
Edge of Box?

Box Depth

Inside Box

Existing Fuse Panel Circuits
	

15A	

20A	

30A	

40A

1 Pole
2 Pole

1 Pole 120 V	

Qty.__________

2 Pole Pullouts (30A max.)*	

Qty.__________

2 Pole Pullouts (60A max.) 	

Qty.__________

GFCB
Required Circuits in replacement breaker Interior.

* CEB has cartridge fuses, Amalgamated & Taylor have Plug fuses.

Installation Problems Foreseen:______________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
  Information Supplied By:_ __________________________________________________________________________ Date:___________________________

58	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Replacement Classic Circuit Breakers

Bolt-On Type BQL Single, Multi-Pole, Duplex™, & Quadplex™

Type BQL



♦ 10,000 / 22,000 Amperes Interrupting Capacity at 120/240VAC.
♦ Captive line screw included (#2 Robertson/Slot).

Product Selection
Table 77. Single and Multi-Pole Bolt-On Classic Replacement Circuit Breakers
1-Pole 120/240VAC

1-Pole 120/240VAC

2-Pole 120/240VAC

3-Pole 120/240VAC

3-Pole 120/240VAC

10kAIC

22kAIC

10kAIC

10kAIC

22kAIC

Ampere Rating

Wire Size Range
(Cu/AL 60ºC or 75ºC)
(AWG)

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

Catalogue Number

15

#14 - 8

BQL15 a

HBQL15

BQL215

BQL315

HBQL315

20

#14 - 8

BQL20

HBQL20

BQL220

BQL320

—

25

#14 - 8

BQL25

HBQL25

BQL225

—

—

30

#14 - 8

BQL30

HBQL30

BQL230

BQL330

HBQL330

40

#14 - 4

BQL40

HBQL40

BQL240

BQL340

—

50

#14 - 4

BQL50

HBQL50

BQL250

BQL350

HBQL350

60

#8 - 2/0

BQL60

HBQL60

BQL260

BQL360

HBQL360

70

#8 - 2/0

—

—

BQL270

BQL370

HBQL370

90

#8 - 2/0

—

—

BQL290

BQL390

HBQL390

100

#8 - 2/0

—

—

BQL2100

BQL3100

HBQL3100

125

#8 - 2/0

—

—

BQL2125

—

—

135

#8 - 2/0

—

—

BQL2135

—

—

Requires Two 1-Inch (25.4mm) Spaces

Requires Three 1-Inch (25.4mm) Spaces

a

Requires One 1-Inch (25.4mm) Space

Type BQL Duplex™ and Quadplex™



♦ 10,000 Amperes Interrupting Capacity at 120/240VAC.
♦ Captive line screw included (#2 Robertson/Slot).

Product Selection
Table 78. Type BQL Duplex™ and Quadplex™ Bolt-On Classic Replacement Circuit Breakers
Duplex™

Quadplex™ Independent Trip

Quadplex™ Independent Trip

Two Single Pole Circuits

Two Single Pole Circuits and One Double Pole Circuit

Two Double Pole Circuits

120VAC

120VAC

120/240VAC

120VAC

120/240VAC

120/240VAC

Ampere Rating

Ampere Rating

Ampere Rating

Ampere Rating

Ampere Rating
Centre (2 Poles)

Wire Size Range
(Cu/AL 60ºC or 75ºC)
(AWG)

Ampere Rating

Catalogue Number

Outer Left (1 Pole)

Centre (2 Poles)

Outer Right (1 Pole)

15-15

BQLT-15

a

15

15

15

BQLT-15-215

15

15

BQLT-215-215

#14 - 4

20-20

BQLT-20 a

15

20

15

BQLT-15-220

20

20

BQLT-220-220

#14 - 4

30-30

BQLT-30

15

25

15

BQLT-15-225

15

30

BQLT-215-230

#14 - 4

—

—

15

30

15

BQLT-15-230

15

40

BQLT-215-240

#14 - 4

—

—

15

40

15

BQLT-15-240

—

—

—

#14 - 4

a

Requires One 1-Inch (25.4mm) Space

Requires Two 1-Inch (25.4mm) Spaces

Outer Left & Right
(2 Poles)

Catalogue
Number

Catalogue
Number

Requires Two 1-Inch (25.4mm) Spaces

Switching duty rated (SWD).
HACR rated.

Internal common trip.
a


	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

59

Replacement Classic Circuit Breakers
Bolt-On Type BQL Ground Fault & Moulded Case Switches

Type BQL Ground Fault Circuit Breakers
♦ 10,000 Amperes Interrupting Capacity at 120/240VAC
♦ 5mA “People Protection”.

Product Selection
Table 79. 5mA Single and Two Pole Bolt-On Ground Fault Circuit Breakers
1-Pole 120VAC

2-Pole 120/240VAC

10kAIC

10kAIC

Ampere Rating

Wire Size Range
Cu/Al 60°C or 75°C
(AWG)

Catalogue Number

Catalogue Number

15

#14 - 8

BQGF15

BQGF215

20

#14 - 8

BQGF20

BQGF220

30

#14 - 8

BQGF30

BQGF230

40

#14 - 8

—

BQGF240

50

#14 - 8

—

BQGF250

Requires One 1-Inch (25.4mm) Space

Requires Two 1-Inch (25.4mm) Spaces

Type BQL Non-Automatic Circuit Breakers (Moulded Case Switches)
♦ 240VAC.
♦ Two pole and three pole versions.

Product Selection
Table 80. Two and Three Pole Bolt-On Non-Automatic Circuit Breakers (Moulded Case Switches)
2-Pole 240VAC

3-Pole 240VAC

Ampere Rating

Wire Size Range
Cu/Al 60°C or 75°C
(AWG)

Catalogue Number

Catalogue Number

60

#8 - 1 Cu #8 - 1/0 Al

BQL260NA

BQL360NA

Requires Two 1-Inch (25.4mm) Spaces

Requires Three 1-Inch (25.4mm) Spaces

Ground Fault Circuit Interrupter

Non-Automatic Circuit Breaker (Moulded Case Switch)

When the Canadian Electrical Code requires the use of an unfused disconnect device as a local isolation switch then a circuit breaker enclosure may be used in conjunction with a moulded case switch (a.k.a.
a non-automatic circuit breaker). For example with an airconditioning unit. The protective device for these applications is located upstream.
a

60	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Replacement Classic Circuit Breakers
Bolt-On Type QBH Single, Multi-Pole, & Accessories

Type QBH
♦ 120/240VAC
♦ 3/4” Form factor.
♦ Designed to fit the classic CEB, Sylvania or Commander Electric design bolt-on loadcentres.
♦ Suitable for loadcentres, lighting & distribution panelboards, and meter centres.
♦ Silver Tungsten contacts with wiping action to prevent carbon buildup on the contact surface.
♦ Handle provides clear indication of ON/OFF/TRIPPED position.
♦ Quick-make / quick-break mechanism provides tease-proof operation.
♦ Internal common trip mechanism on two pole circuit breakers.
♦ Each breaker is electronically calibrated for 40°C.
♦ Compression moulded housing and handle for durability and service.

Product Selection
Table 81. Single and Two Pole Bolt-On Classic Replacement Circuit Breakers
1-Pole 120VAC

2-Pole 120/240VAC

10kAIC

10kAIC

Catalogue Number

Catalogue Number

Ampere Rating

Wire Size Range
60°C or 75°C (AWG)

15

#14 - 10 CU, #12 - 10 AL

QBH15

QBH215

20

#14 - 10 CU, #12 - 10 AL

QBH20

QBH220

25

#14 - 10 CU, #12 - 10 AL

QBH25

QBH225

30

#10 - 2 CU, #10 - 1 AL

QBH30

QBH230

40

#10 - 2 CU, #10 - 1 AL

QBH40

QBH240

50

#10 - 2 CU, #10 - 1 AL

QBH50

QBH250

60

#10 - 2 CU, #10 - 1 AL

QBH60

QBH260

70

#10 - 2 CU, #10 - 1 AL

—

QBH270

90

#10 - 2 CU, #10 - 1 AL

—

QBH290

100

#10 - 2 CU, #10 - 1 AL

—

QBH2100

125

#10 - 1 CU

—

QBH2125

Requires One 3/4-Inch (19.1mm) Space

Requires Two 3/4-Inch (19.1mm) Spaces

Type QBH Accessories
Product Selection
Table 82. Type QBH Classic Bolt-On Circuit Breaker Accessories
Description

Catalogue Number

Filler Plate (Package of 50)

QBF

Handle Tie

QBHT

	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

61

Replacement Classic Circuit Breakers
Plug-In Type BJ Two & Three Pole

Type BJ 
♦ Main circuit breakers for classic Westinghouse NovaLine loadcentres
♦ 10,000 Amperes Interrupting Capacity at 120/240VAC

Product Selection
Table 83. Type BJ Two and Three Pole Plug-In Classic Replacement Circuit Breakers
2-Pole 120/240VAC

3-Pole 120/240VAC

1 per Shelf Carton

1 per Shelf Carton

10kAIC

10kAIC

Ampere Rating

Wire Size Range
Cu/Al 60°C or 75°C
(AWG)

Catalogue Number

Catalogue Number

125

#2 - 300MCM

BJ2125

BJ3125

150

#2 - 300MCM

BJ2150

BJ3150

175

#2 - 300MCM

BJ2175

BJ3175

200

#2 - 300MCM

BJ2200

BJ3200

Requires Four a 1-Inch (25.4mm) Spaces

Requires Six  1-Inch (25.4mm) Spaces

When mounted the type BJ circuit breakers span both sides of the bus bar occupying an equivalent number of pole spaces on both the left and right side of the loadcentre. For example a two pole type BJ
circuit breaker occupies 2 pole spaces on the left and the same number of spaces on the right thus requiring four 1-inch spaces.

BJ breakers are also approved as branch circuit breakers on CPM/CPL panels 200A and greater.

When mounted the type BJ circuit breakers span both sides of the bus bar occupying an equivalent number of pole spaces on both the left and right side of the loadcentre. For example a three pole type BJ
circuit breaker occupies 3 pole spaces on the left and the same number of spaces on the right thus requiring six 1-inch spaces.
a

62	

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

Pressure Switches

Pressure Switches
♦ Ensures smooth delivery of water into your home.
♦ Commercial, residential, or agricultural applications.
♦ Can be used on all types of pumps.
♦ Pressure ratings 20 - 40PSI, 30 - 50PSI, and 40 - 60PSI.
♦ Adjustable cut-in and cut-out pressure.
♦ Easy installation.
♦ CSA® certified and UL® listed.
♦ Pulsation plug models prevent pump cycling due to water surges.
♦ Low pressure cut-off models prevent pump burn out due to lack of well water (10PSI below turn on pressure).
♦ 3 Year product warranty.

Product Selection

Pressure Switch

Table 84. Pressure Switches
Description

Enclosure Style

Catalogue Number

20-40 PSI Pressure Switch

NEMA 1

CHWPS2040D

20-40 PSI Pressure Switch with Pulsation Plug

NEMA 1

CHWPS2040DP

20-40 PSI Pressure Switch with Low Pressure Cut-Off

NEMA® 1

CHWPS2040DL

30-50 PSI Pressure Switch

NEMA 1

CHWPS3050D

30-50 PSI Pressure Switch with Low Pressure Cut-Off

NEMA® 1

CHWPS3050DL

40-60 PSI Pressure Switch

NEMA 1

CHWPS4060D

®
®

®

®

Table 85. Pressure Switch Ratings
Phase

Voltage (AC)

Amperage

Horsepower

Single

115

20

1.5

Handle Tie

230

12

2.0

Table 86. Pressure Switch Cross-Reference
Description

Eaton Catalogue
Number

Square D® Catalogue
Number

Flotec® Catalogue
Number

Water Ace® Catalogue
Number

Furnas® Catalogue
Number

20-40 PSI Pressure Switch

CHWPS2040D

9013FSG2J20

—

15767A510

69WA4Z2040

20-40 PSI Pressure Switch with Pulsation Plug

CHWPS2040DP

9013FSG2J20P

—

—

69WA4Z2040B

20-40 PSI Pressure Switch with Low Pressure Cut-Off

CHWPS2040DL

9013FSG2J20M4

—

—

69WEC

30-50 PSI Pressure Switch

CHWPS3050D

9013FSG2J21

TC2151

15760A501

69WA4

30-50 PSI Pressure Switch with Low Pressure Cut-Off

CHWPS3050DL

9013FSG2J21M4

FP217-1140

19180A501

—

40-60 PSI Pressure Switch

CHWPS4060D

9013FSG2J24

TC2153

—

69WA4Z4060

CSA is a registered trademark of the Canadian Standards Association.
UL is a federally registered trademark of Underwriters Laboratories Inc.
NEMA Is the registered trademark and service mark of the National Electrical Manufacturers Association.
Square D is a federally registered trademark of Schneider Electric.
Flotec is a registered trademark of Flotec.
Furnas is a registered trademark of Siemens Energy and Automation, Inc.
Water Ace is a registered trademark of the Pentair Pump Group.
	

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

63

Catalogue Number Index

Index
Symbols
1224INT125B ...............................
1624INT125B ...............................
1SL150PCO . .................................
1SL300PCO . .................................
1SL500PCO . .................................
1SL502 	........................................
1SL502NV ....................................
1SL502NVE ..................................
1SL502S .......................................
1SL502VE .....................................
1SL602 	........................................
1SL602NV ....................................
1SL602NVE ..................................
1SL602S .......................................
1SL602VE .....................................
1SL702 	........................................
1SL702NV ....................................
1SL702NVE ..................................
1SL702S .......................................
1SL702VE .....................................
2024INT125B ...............................
2424INT125B ...............................
2SL150PCO . .................................
2SL300PCO . .................................
2SL500PCO . .................................
2SL502 	........................................
2SL502NV ....................................
2SL502NVE ..................................
2SL502S .......................................
2SL502VE .....................................
2SL602 	........................................
2SL602NV ....................................
2SL602NVE ..................................
2SL602S .......................................
2SL602VE .....................................
2SL702 	........................................
2SL702NV ....................................
2SL702NVE ..................................
2SL702S .......................................
2SL702VE .....................................
2SL706S .......................................
3BRS225 . .....................................
3BRS400 . .....................................
3BRSF150 .....................................
3CBL118 .......................................
3CBL118CU ..................................
3CBL130 .......................................
3CBL130CU ..................................
3CBL142 .......................................
3CBL142CU ..................................
3CBL218 .......................................
3CBL230 .......................................
3CBL230CU ..................................
3CBL242 .......................................
3CBL242CU ..................................
3CBM118 .....................................
3CBM118CU . ...............................
3CBM130 .....................................
3CBM130CU . ...............................
3CBM142 .....................................
64	

21
21
47
47
47
48
49
49
48
49
48
49
49
48
49
48
49
49
48
49
21
21
47
47
47
48
49
49
48
49
48
49
49
48
49
48
49
49
48
49
48
11
11
11
35
36
35
36
35
36
35
35
36
35
36
33
34
33
34
33

3CBM142CU . ............................... 34
3CBM218 ..................................... 33
3CBM230 ..................................... 33
3CBM230CU . ............................... 34
3CBM242 ..................................... 33
3CBSF100 ..................................... 40
3CBSF225 ..................................... 40
3CCPL103 ....................................... 8
3CPL112 ......................................... 8
3CPL112COV ................................ 11
3CPL124 ......................................... 8
3CPL124COV ................................ 11
3CPL130 ......................................... 8
3CPL130COV ................................ 11
3CPL136 ......................................... 8
3CPL136COV ................................ 11
3CPL218 ......................................... 8
3CPL218COV ................................ 11
3CPL224 ......................................... 8
3CPL224COV ................................ 11
3CPL230 ......................................... 8
3CPL230COV ................................ 11
3CPL242 ......................................... 8
3CPL242COV ................................ 11
3CPL442 ......................................... 8
3CPM112 . ...................................... 4
3CPM112COV . ............................. 11
3CPM130 . ...................................... 4
3CPM130COV . ............................. 11
3CPM230 . ...................................... 4
3CPM230COV . ............................. 11
3CPM442 . ...................................... 4
48INT125B ................................... 21
52-3125-5 ..................................... 11
816INT125B ................................. 21
B
BAB1010 ......................................
BAB1015 ......................................
BAB1015D ....................................
BAB1020 ......................................
BAB1020D ....................................
BAB1025 ......................................
BAB1030 ......................................
BAB1040 37
BAB1050 ......................................
BAB1060 ......................................
BAB1070 ......................................
BAB2015 ......................................
BAB2020 ......................................
BAB2030 ......................................
BAB2040 ......................................
BAB2050 ......................................
BAB2060 ......................................
BAB2070 ......................................
BAB2090 ......................................
BAB2100 ......................................
BAB2125 ......................................
BAB3015H ....................................
BAB3020H ....................................
BAB3030H ....................................
BAB3040H ....................................
BAB3050H ....................................
BAB3060H ....................................
BAB3070H ....................................

37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37

BAB3090H ....................................
BAB3100H ....................................
BHGW-10 .....................................
BHLW-10 ......................................
BHLW1-10 ....................................
BHLW2-10 ....................................
BJ2125 	........................................
BJ2150 	........................................
BJ2175 	........................................
BJ2200 	........................................
BJ3125 	........................................
BJ3150 	........................................
BJ3175 	........................................
BJ3200 	........................................
BP16 	 ........................................
BP18 	 ........................................
BP2 	 ........................................
BP21 	 ........................................
BP23 	 ........................................
BP24 	 ........................................
BP27 	 ........................................
BP31 	 ........................................
BP3110C .......................................
BP32 	 ........................................
BP4 	 ........................................
BP41 	 ........................................
BP54 	 ........................................
BQGF15 .	.......................................
BQGF20 .	.......................................
BQGF215 ......................................
BQGF220 ......................................
BQGF230 ......................................
BQGF240 ......................................
BQGF250 ......................................
BQGF30 .	.......................................
BQHT-10 .......................................
BQL-10 	........................................
BQL15 	 ........................................
BQL20 	 ........................................
BQL2100 .......................................
BQL2125 .......................................
BQL2135 .......................................
BQL215 	........................................
BQL220 	........................................
BQL225 	........................................
BQL230 	........................................
BQL240 	........................................
BQL25 	 ........................................
BQL250 	........................................
BQL260 	........................................
BQL260NA . ..................................
BQL270 	........................................
BQL290 	........................................
BQL30 	 ........................................
BQL3100 .......................................
BQL315 	........................................
BQL320 	........................................
BQL330 	........................................
BQL340 	........................................
BQL350 	........................................
BQL360 	........................................
BQL360NA . ..................................
BQL370 	........................................
BQL390 	........................................
BQL40 	 ........................................

37
37
20
20
20
20
62
62
62
62
62
62
62
62
14
14
14
14
14
14
14
14
11
14
14
14
14
60
60
60
60
60
60
60
60
20
40
59
59
59
59
59
59
59
59
59
59
59
59
59
60
59
59
59
59
59
59
59
59
59
59
60
59
59
59

BQL50 	 ........................................
BQL60 	 ........................................
BQLT-15 ........................................
BQLT-15-215 .................................
BQLT-15-220 .................................
BQLT-15-225 .................................
BQLT-15-230 .................................
BQLT-15-240 .................................
BQLT-20 ........................................
BQLT-215-215 ...............................
BQLT-215-230 ...............................
BQLT-215-240 ...............................
BQLT-220-220 ...............................
BQLT-30 ........................................
BR115 	 ........................................
BR115AF . .....................................
BR115E 	........................................
BR120 	 ........................................
BR120AF . .....................................
BR120E 	........................................
BR125 	 ........................................
BR125E 	........................................
BR130 	 ........................................
BR130E 	........................................
BR135 	 ........................................
BR135E 	........................................
BR140 	 ........................................
BR140E 	........................................
BR150 	 ........................................
BR150E 	........................................
BR2100 	........................................
BR2100E .......................................
BR2100NA . ..................................
BR2125 	........................................
BR215 	 ........................................
BR215E 	........................................
BR220 	 ........................................
BR220E 	........................................
BR225 	 ........................................
BR225E 	........................................
BR230 	 ........................................
BR230E 	........................................
BR235 	 ........................................
BR235E 	........................................
BR240 	 ........................................
BR240E 	........................................
BR245 	 ........................................
BR245E 	........................................
BR250 	 ........................................
BR250E 	........................................
BR250NA . ....................................
BR260 	 ........................................
BR260E 	........................................
BR260NA . ....................................
BR270 	 ........................................
BR270E 	........................................
BR280 	 ........................................
BR280E 	........................................
BR290 	 ........................................
BR290E 	........................................
BR3100 	........................................
BR3100E .......................................
BR315 	 ........................................
BR315E 	........................................
BR320 	 ........................................

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

59
59
59
59
59
59
59
59
59
59
59
59
59
59
13
15
17
13
15
17
13
17
13
17
13
17
13
17
13
17
13
17
18
13
13
17
13
17
13
17
13
17
13
17
13
17
13
17
13
17
18
13
17
18
13
17
13
17
13
17
13
17
13
17
13

Catalogue Number Index

BR320E ......................................... 17
BR325 ........................................... 13
BR325E ......................................... 17
BR330 ........................................... 13
BR330E ......................................... 17
BR335 ........................................... 13
BR335E ......................................... 17
BR340 ........................................... 13
BR340E ......................................... 17
BR345 ........................................... 13
BR345E ......................................... 17
BR350 ........................................... 13
BR350E ......................................... 17
BR360 ........................................... 13
BR360E ......................................... 17
BR370 ........................................... 13
BR370E ......................................... 17
BR380 ........................................... 13
BR380E ......................................... 17
BR390 ........................................... 13
BR390E ......................................... 17
BRC115AF .................................... 15
BRC120AF .................................... 15
BRDL1-10 ............................... 20, 40
BRFP 	...................................... 11, 40
BRH115 ........................................ 13
BRH115E ...................................... 17
BRH120 ........................................ 13
BRH120E ...................................... 17
BRH125 ........................................ 13
BRH125E ...................................... 17
BRH130 ........................................ 13
BRH130E ...................................... 17
BRH135 ........................................ 13
BRH135E ...................................... 17
BRH140 ........................................ 13
BRH140E ...................................... 17
BRH145 ........................................ 13
BRH145E ...................................... 17
BRH150 ........................................ 13
BRH150E ...................................... 17
BRH160 ........................................ 13
BRH160E ...................................... 17
BRH170 ........................................ 13
BRH170E ...................................... 17
BRH2100 ...................................... 13
BRH2100E .................................... 17
BRH215 ........................................ 13
BRH215E ...................................... 17
BRH220 ........................................ 13
BRH220E ...................................... 17
BRH225 ........................................ 13
BRH225E ...................................... 17
BRH230 ........................................ 13
BRH230E ...................................... 17
BRH235 ........................................ 13
BRH235E ...................................... 17
BRH240 ........................................ 13
BRH240E ...................................... 17
BRH245 ........................................ 13
BRH245E ...................................... 17
BRH250 ........................................ 13
BRH250E ...................................... 17
BRH260 ........................................ 13
BRH260E ...................................... 17
	

BRH270 ........................................
BRH270E ......................................
BRH280 ........................................
BRH280E ......................................
BRH290 ........................................
BRH290E ......................................
BRH3100 ......................................
BRH3100E ....................................
BRH315 ........................................
BRH315E ......................................
BRH320 ........................................
BRH320E ......................................
BRH325 ........................................
BRH325E ......................................
BRH330 ........................................
BRH330E ......................................
BRH335 ........................................
BRH335E ......................................
BRH340 ........................................
BRH340E ......................................
BRH345 ........................................
BRH345E ......................................
BRH350 ........................................
BRH350E ......................................
BRH360 ........................................
BRH360E ......................................
BRH370 ........................................
BRH370E ......................................
BRH380 ........................................
BRH380E ......................................
BRH390 ........................................
BRH390E ......................................
BRL215AF .....................................
BRL215AFIT ..................................
BRL220AF .....................................
BRL220AFIT ..................................
BRLW-10 ......................................
BRLW1-10 ....................................
BRLW2-10 ....................................
BRQLW-10 ....................................
BRS225 . .......................................
BRS400 . .......................................
BRSF125 .......................................
BRSURGE .....................................
BWH2125 .....................................
BWH2150 .....................................
BWH2175 .....................................
BWH2200 .....................................

13
17
13
17
13
17
13
17
13
17
13
17
13
17
13
17
13
17
13
17
13
17
13
17
13
17
13
17
13
17
13
17
15
15
15
15
20
20
20
20
11
11
11
44
19
19
19
19

C
CBL118 .........................................
CBL118CU ....................................
CBL130 .........................................
CBL130CU ....................................
CBL142 .........................................
CBL142CU ....................................
CBL218 .........................................
CBL218CU ....................................
CBL230 .........................................
CBL230CU ....................................
CBL242 .........................................
CBL242CU ....................................
CBM118 .......................................
CBM118CU . .................................
CBM130 .......................................

35
36
35
36
35
36
35
36
35
36
35
36
33
34
33

CBM130CU . ................................. 34
CBM142 ....................................... 33
CBM142CU . ................................. 34
CBM218 ....................................... 33
CBM218CU . ................................. 34
CBM230 ....................................... 33
CBM230CU . ................................. 34
CBM242 ....................................... 33
CBSF100 ....................................... 40
CBSF225 ....................................... 40
CC3100 ......................................... 19
CC3125 ......................................... 19
CC3150 ......................................... 19
CC3200 ......................................... 19
CCL300 ......................................... 20
CCPL	 ........................................... 20
CCPL102 ......................................... 6
CCPL104 ......................................... 6
CCPL108 ......................................... 6
CH110 . ......................................... 27
CH115 . ......................................... 27
CH115AF ...................................... 29
CH115AFPN . ................................ 29
CH115EPD .................................... 30
CH115GF ...................................... 30
CH115GFPN . ................................ 30
CH120 . ......................................... 27
CH120AF ...................................... 29
CH120AFPN . ................................ 29
CH120EPD .................................... 30
CH120GF ...................................... 30
CH120GFPN . ................................ 30
CH125 . ......................................... 27
CH125EPD .................................... 30
CH125GF ...................................... 30
CH130 . ......................................... 27
CH130EPD .................................... 30
CH130GF ...................................... 30
CH135 . ......................................... 27
CH140 . ......................................... 27
CH145 . ......................................... 27
CH150 . ......................................... 27
CH160 . ......................................... 27
CH170 . ......................................... 27
CH210 . ......................................... 27
CH2100 . ....................................... 27
CH2110 . ....................................... 27
CH2125 . ....................................... 27
CH215 . ......................................... 27
CH215AF ...................................... 29
CH215AFIT ................................... 29
CH215EPD .................................... 30
CH215GF ...................................... 30
CH220 . ......................................... 27
CH220AF ...................................... 29
CH220AFIT ................................... 29
CH220EPD .................................... 30
CH220GF ...................................... 30
CH225 . ......................................... 27
CH225GF ...................................... 30
CH230 . ......................................... 27
CH230EPD .................................... 30
CH230GF ...................................... 30
CH235 . ......................................... 27
CH235GF ...................................... 30

CH240 . .........................................
CH240EPD ....................................
CH240GF ......................................
CH245 . .........................................
CH245GF ......................................
CH250 . .........................................
CH250EPD ....................................
CH250GF ......................................
CH260 . .........................................
CH260EPD ....................................
CH260GF ......................................
CH270 . .........................................
CH280 . .........................................
CH290 . .........................................
CH30SPA ......................................
CH30SPALARM ............................
CH310 . .........................................
CH3100 . .......................................
CH315 . .........................................
CH320 . .........................................
CH325 . .........................................
CH330 . .........................................
CH335 . .........................................
CH340 . .........................................
CH345 . .........................................
CH350 . .........................................
CH360 . .........................................
CH370 . .........................................
CH380 . .........................................
CH390 . .........................................
CH40SPA ......................................
CH40SPALARM ............................
CH50SPA ......................................
CH50SPALARM ............................
CH60SPA ......................................
CH60SPALARM ............................
CH9FL ...........................................
CHF115 .........................................
CHF120 .........................................
CHF125 .........................................
CHF130 .........................................
CHF215 .........................................
CHF220 .........................................
CHF225 .........................................
CHF230 .........................................
CHFP 	............................................
CHHT 	............................................
CHLO 	............................................
CHM24PN100 ..............................
CHM32PN100 ..............................
CHM32PN200 ..............................
CHM42PN200 ..............................
CHM60PN200L . ...........................
CHNL24PN125 .............................
CHNL32PN125 .............................
CHNL32PN225 .............................
CHNL42PN225 .............................
CHNS . ..........................................
CHNT1515 ....................................
CHNT1520 ....................................
CHNT2020 ....................................
CHP110 . .......................................
CHP115 . .......................................
CHP120 . .......................................
CHP125 . .......................................

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

27
30
30
27
30
27
30
30
27
30
30
27
27
27
43
43
27
27
27
27
27
27
27
27
27
27
27
27
27
27
43
43
43
43
43
43
11
27
27
27
27
27
27
27
27
32
32
32
26
26
26
26
26
26
26
26
26
32
27
27
27
28
28
28
28
65

Catalogue Number Index

CHP130 . ....................................... 28
CHP135 . ....................................... 28
CHP140 . ....................................... 28
CHP145 . ....................................... 28
CHP150 . ....................................... 28
CHP160 . ....................................... 28
CHP170 . ....................................... 28
CHP210 . ....................................... 28
CHP2100 . ..................................... 28
CHP2110 . ..................................... 28
CHP2125 . ..................................... 28
CHP215 . ....................................... 28
CHP220 . ....................................... 28
CHP225 . ....................................... 28
CHP230 . ....................................... 28
CHP235 . ....................................... 28
CHP240 . ....................................... 28
CHP245 . ....................................... 28
CHP250 . ....................................... 28
CHP260 . ....................................... 28
CHP270 . ....................................... 28
CHP280 . ....................................... 28
CHP290 . ....................................... 28
CHP310 . ....................................... 28
CHP3100 . ..................................... 28
CHP315 . ....................................... 28
CHP320 . ....................................... 28
CHP325 . ....................................... 28
CHP330 . ....................................... 28
CHP335 . ....................................... 28
CHP340 . ....................................... 28
CHP345 . ....................................... 28
CHP350 . ....................................... 28
CHP360 . ....................................... 28
CHP370 . ....................................... 28
CHPL 	............................................ 32
CHPLGF . ....................................... 32
CHRLS .......................................... 32
CHSF2125 . ................................... 32
CHSPALARM ................................ 43
CHSPCABLE . ................................ 45
CHSPFMKIT .................................. 45
CHSPT1-208Y ............................... 46
CHSPT1MAX ................................ 46
CHSPT1MICRO ............................. 46
CHSPT1ULTRA . ............................ 46
CHSPT23PACK . ............................ 44
CHSPT2MAX ................................ 44
CHSPT2MICRO ............................. 44
CHSPT2ULTRA . ............................ 44
CHSPTELE . ................................... 45
CHWPS2040D .............................. 63
CHWPS2040DL ............................ 63
CHWPS2040DP ............................ 63
CHWPS3050D .............................. 63
CHWPS3050DL ............................ 63
CHWPS4060D .............................. 63
CPL072 ......................................... 10
CPL072FGP ................................... 10
CPL072R ....................................... 10
CPL072RGP . ................................. 10
CPL072SGP . ................................. 10
CPL112 ........................................... 6
CPL112COV .................................. 11
CPL112G3 ..................................... 42
66	

CPL112G6 ..................................... 42
CPL112GI3 .................................... 42
CPL116 ........................................... 6
CPL116COV .................................. 11
CPL116W . ...................................... 6
CPL120 ........................................... 6
CPL120COV .................................. 11
CPL120G6 ..................................... 42
CPL120W . ...................................... 6
CPL130 ........................................... 6
CPL130COV .................................. 11
CPL130G6 ..................................... 42
CPL130W . ...................................... 6
CPL220 ........................................... 6
CPL220COV .................................. 11
CPL220W . ...................................... 6
CPL240 ........................................... 6
CPL240COV .................................. 11
CPL240W . ...................................... 6
CPL400KIT .................................... 11
CPL442 ........................................... 6
CPM112 . ........................................ 2
CPM112COV . ............................... 11
CPM112LMB .................................. 2
CPM116 . ........................................ 2
CPM116COV . ............................... 11
CPM116LMB .................................. 2
CPM116Z . ...................................... 2
CPM120 . ........................................ 2
CPM120COV . ............................... 11
CPM120H ....................................... 2
CPM120LMB .................................. 2
CPM120Z . ...................................... 2
CPM126GEN ................................ 42
CPM130 . ........................................ 2
CPM130COV . ............................... 11
CPM130H ....................................... 2
CPM130Z . ...................................... 2
CPM1520 . ...................................... 2
CPM1530 . ...................................... 2
CPM1540 . ...................................... 2
CPM216 . ........................................ 2
CPM216COV . ............................... 11
CPM220 . ........................................ 2
CPM220COV . ............................... 11
CPM230 . ........................................ 2
CPM230COV . ............................... 11
CPM236GEN ................................ 42
CPM240 . ........................................ 2
CPM240COV . ............................... 11
CPM400KIT .................................. 11
CPM442 . ........................................ 2
CQLP12100 ................................... 56
CQLP8100 ..................................... 56
CSABP4683B ................................ 56
CSABP4734B ................................ 56
CSH2100N . .................................. 31
CSH2150N . .................................. 31
CSH2200N . .................................. 31
CSR2125N .................................... 19
CSR2150N .................................... 19
CSR2200N .................................... 19
CVRSCRW .................................... 11
D

DIRCARD42 ..................................
DIRSLEEVE ...................................
DNBA1515 ...................................
DNBA2020 ...................................
DNBA3030 ...................................
DNPL1515 ....................................
DNPL151515 ................................
DNPL1520 ....................................
DNPL152015 ................................
DNPL152515 ................................
DNPL1530 ....................................
DNPL153015 ................................
DNPL154015 ................................
DNPL155015 ................................
DNPL2020 ....................................
DNPL215215 ................................
DNPL215220 ................................
DNPL215230 ................................
DNPL215240 ................................
DNPL220220 ................................
DNPL220230 ................................
DS075H1 ......................................
DS100H1 ......................................
DS125H1 ......................................
DS150H1 ......................................
DS200H1 ......................................
DS200H2 ......................................
DS250H2 ......................................
DS300H2 ......................................

40
40
38
38
38
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
11
11
11
11
11
11
11
11

G
GFCB115 . .....................................
GFCB120 . .....................................
GFCB125 . .....................................
GFCB130 . .....................................
GFCB140 . .....................................
GFCB215 . .....................................
GFCB220 . .....................................
GFCB225 . .....................................
GFCB230 . .....................................
GFCB240 . .....................................
GFCB250 . .....................................
GFCB260 . .....................................
GFCBH115 ....................................
GFCBH120 ....................................
GFCBH125 ....................................
GFCBH130 ....................................
GFCBH215 ....................................
GFCBH220 ....................................
GFCBH225 ....................................
GFCBH230 ....................................
GFEP115 .......................................
GFEP120 .......................................
GFEP125 .......................................
GFEP130 .......................................
GFEP215 .......................................
GFEP220 .......................................
GFEP225 .......................................
GFEP230 .......................................
GFEP240 .......................................
GFEP250 .......................................
GFXB115B2 ..................................
GFXB120B2 ..................................
GFXB125B2 ..................................
GFXB130B2 ..................................

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
18
18
18
18

H
HBQL15 ........................................
HBQL20 ........................................
HBQL25 ........................................
HBQL30 ........................................
HBQL3100 ....................................
HBQL315 ......................................
HBQL330 ......................................
HBQL350 ......................................
HBQL360 ......................................
HBQL370 ......................................
HBQL390 ......................................
HBQL40 ........................................
HBQL50 ........................................
HBQL60 ........................................
HLW1-10 ......................................

59
59
59
59
59
59
59
59
59
59
59
59
59
59
20

I
ISGRD ..................................... 11, 40
L
LCCS 	............................................ 32
M
MCBL300 . .................................... 20
MCBPL . .................................. 20, 32
N
NL20 	............................................
NL30 	............................................
NL300 ...........................................
NSP42 ..........................................

11
11
11
11

P
P48G11S03CUB . ..........................
P48G11S03P . ...............................
P48G11S05CUB . ..........................
P48G11S05P . ...............................
P48G11S07CUB . ..........................
P48G11S07P . ...............................
P48G11S10CUB . ..........................
P48G11S10P . ...............................
P48G11S15CUB . ..........................
P48G11S15P . ...............................
P48G11S25CUB . ..........................
P48G11S25P . ...............................
P48G28T15CUB ............................
P48G28T15P .................................
P48G28T21CUB ............................
P48G28T21P .................................
P48G28T30CUB ............................
P48G28T30P .................................
P60G11S03CUB . ..........................
P60G11S05CUB . ..........................
P60G11S05P . ...............................
P60G11S07CUB . ..........................
P60G11S07P . ...............................
P60G11S10CUB . ..........................
P60G11S10P . ...............................
P60G11S15CUB . ..........................
P60G11S15P . ...............................
P60G11S25CUB . ..........................

Residential & light commerical distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca

54
53
54
53
54
53
54
53
54
53
54
53
54
53
54
53
54
53
54
54
53
54
53
54
53
54
53
54

Catalogue Number Index

P60G11S25P . ...............................
P60G28T15CUB ............................
P60G28T15P .................................
P60G28T21CUB ............................
P60G28T21P .................................
P60G28T30CUB ............................
P60G28T30P .................................
POWER3 .......................................
POWER5 .......................................

53
54
53
54
53
54
53
45
45

Q
QBAF1015 .................................... 38
QBAF1020 .................................... 38
QBAF2015 .................................... 38
QBAF2015IT ................................. 38
QBAF2020 .................................... 38
QBAF2020IT ................................. 38
QBAG1015 . .................................. 38
QBAG1020 . .................................. 38
QBAG2015 . .................................. 38
QBAG2020 . .................................. 38
QBF 	 ............................................ 61
QBGF1015 .................................... 39
QBGF1020 .................................... 39
QBGF1030 .................................... 39
QBGF1040 .................................... 39
QBGF2015 .................................... 39
QBGF2020 .................................... 39
QBGF2030 .................................... 39
QBGF2040 .................................... 39
QBGF2050 .................................... 39
QBGFEP1015 ................................ 39
QBGFEP1020 ................................ 39
QBGFEP1025 ................................ 39
QBGFEP1030 ................................ 39
QBGFEP2015 ................................ 39
QBGFEP2020 ................................ 39
QBGFEP2025 ................................ 39
QBGFEP2030 ................................ 39
QBH15 .......................................... 61
QBH20 .......................................... 61
QBH2100 ...................................... 61
QBH2125 ...................................... 61
QBH215 ........................................ 61
QBH220 ........................................ 61
QBH225 ........................................ 61
QBH230 ........................................ 61
QBH240 ........................................ 61
QBH25 .......................................... 61
QBH250 ........................................ 61
QBH260 ........................................ 61
QBH270 ........................................ 61
QBH290 ........................................ 61
QBH30 .......................................... 61
QBH40 .......................................... 61
QBH50 .......................................... 61
QBH60 .......................................... 61
QBHAF1015 .................................. 38
QBHAF1020 .................................. 38
QBHAF2015 .................................. 38
QBHAF2015IT ............................... 38
QBHAF2020 .................................. 38
QBHAF2020IT ............................... 38
QBHAG1015 ................................. 38
QBHAG1020 ................................. 38
	

QBHAG2015 ................................. 38
QBHAG2020 ................................. 38
QBHGFEP1015 .............................. 39
QBHGFEP1020 .............................. 39
QBHGFEP1025 .............................. 39
QBHGFEP1030 .............................. 39
QBHGFEP2015 .............................. 39
QBHGFEP2020 .............................. 39
QBHGFEP2025 .............................. 39
QBHGFEP2030 .............................. 39
QBHT 	............................................ 61
QBHW1015 .................................. 37
QBHW1020 .................................. 37
QBHW1030 .................................. 37
QBHW1040 .................................. 37
QBHW1050 .................................. 37
QBHW1060 .................................. 37
QBHW1070 .................................. 37
QBHW2015 .................................. 37
QBHW2020 .................................. 37
QBHW2030 .................................. 37
QBHW2040 .................................. 37
QBHW2050 .................................. 37
QBHW2060 .................................. 37
QBHW2070 .................................. 37
QBHW2090 .................................. 37
QBHW2100 .................................. 37
QBHW2125 .................................. 37
QBHW3015 .................................. 37
QBHW3020 .................................. 37
QBHW3030 .................................. 37
QBHW3040 .................................. 37
QBHW3050 .................................. 37
QBHW3060 .................................. 37
QBHW3070 .................................. 37
QBHW3090 .................................. 37
QBHW3100 .................................. 37
QL123PL ....................................... 40
QL1NPL . ....................................... 40
QL23NPL . ..................................... 40
QLPT16AD .................................... 57
QLPT16D . ..................................... 57
QLPT19D . ..................................... 57
QLPT20AD .................................... 57
QLPT22AD .................................... 57
QLPT24D . ..................................... 57

RCPL220 ......................................... 7
RCPL240 ......................................... 7
RCPM108M .................................. 50
RCPM112 ....................................... 3
RCPM120 ....................................... 3
RCPM130 ....................................... 3
RCPM1530 ..................................... 3
RCPM1GF10 ................................. 51
RCPM1GF6H . ............................... 51
RCPM208M .................................. 50
RCPM220 ....................................... 3
RCPM230 ....................................... 3
RCPM240 ....................................... 3
RCPM2GF10 ................................. 51
RCPM2GF6H . ............................... 51
RH100P . ....................................... 11
RH125P . ....................................... 11
RH75P . ......................................... 11
S
SCONST7 .....................................
SMAX7 .........................................
SMAX7C . .....................................
SMAX7T .......................................
SMAX8TC . ...................................
SMICRO1C ...................................
SMICRO1T . ..................................
SMICRO6T . ..................................
SMICRO6TC .................................
SMICRO7 . ....................................
SP1DINRAILKIT ............................
SULT10TC .....................................
SULT12TC .....................................
SULT8T .........................................

45
45
45
45
45
45
45
45
45
45
46
45
45
45

T
TDL 	 ................................ 11, 32, 40
THOW-10 ..................................... 20
THS1 	............................................ 20

R
R3CCPL103 ..................................... 9
R3CPL112 ....................................... 9
R3CPL130 ....................................... 9
R3CPL136 ....................................... 9
R3CPL230 ....................................... 9
R3CPL242 ....................................... 9
R3CPM112 ..................................... 5
R3CPM130 ..................................... 5
R3CPM230 ..................................... 5
RCCHL102 .................................... 26
RCCPL102 ....................................... 7
RCCPL104 ....................................... 7
RCCPL108 ....................................... 7
RCPL112 ......................................... 7
RCPL112GI3 . ................................ 42
RCPL120 ......................................... 7
RCPL130 ......................................... 7

residential & light commercial distribution products  PG.31.02.P.K – September 2011 www.eatoncanada.ca	

67

Eaton is dedicated to ensuring that reliable, efficient and safe
power is available when it’s needed most. With unparalleled
knowledge of electrical power management across industries,
experts at Eaton deliver customized, integrated solutions to
solve our customers’ most critical challenges.
Our focus is on delivering the right solution for the application.
But, decision makers demand more than just innovative products.
They turn to Eaton for an unwavering commitment to personal
support that makes customer success a top priority. For more
information, visit www.eaton.com/electrical.

Eaton Corporation
Electrical Sector
1111 Superior
Ave.
Eaton
Corporation
Cleveland,
OH 44114
5050
Mainway
United States
Burlington,
ON L7L 5Z1
877-ETN-CARE
(877-386-2273)
tel:
1-800-268-3578
Eaton.com
www.eatoncanada.ca
© 2009
2011 Eaton Corporation
©
All Rights
Rights Reserved
Reserved
All
Printed in
in Canada
USA
Printed
Publication
No. BRXXXXXXXXE / XXX
Form
No. PG.31.02.P.K
Month 20112011
September

Eaton is a registered trademark
of Eaton Corporation.
All trademarks are property of their
respective owners.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2011:09:09 11:01:18-04:00
Creator                         : Adobe InDesign CS2 (4.0)
Modify Date                     : 2011:09:26 07:53:15-04:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Instance ID                     : uuid:9763484c-7e9d-4143-9064-9cd4c284f6c7
Document ID                     : adobe:docid:indd:a9a1608c-ba93-11e0-9b17-82a7c1dc093c
Rendition Class                 : proof:pdf
Derived From Instance ID        : 25e47512-ba8d-11e0-9336-836ee047538a
Derived From Document ID        : adobe:docid:indd:7d494d20-9348-11e0-8f9a-97a1316a283a
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 200.00, 96.00, 300.00, 200.00, 800.00, 300.00, 200.00, 72.00, 300.00, 72.00
Manifest Placed Y Resolution    : 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 200.00, 96.00, 300.00, 200.00, 800.00, 300.00, 200.00, 72.00, 300.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:6FBDE058BC3311DC8E50B2F907B49664, uuid:E93F2EB9D0AC11E0858EF1F4BA54EE25, uuid:E93F2EB9D0AC11E0858EF1F4BA54EE25, uuid:1FD3256CD09711E0858EF1F4BA54EE25, uuid:E93F2EB9D0AC11E0858EF1F4BA54EE25, uuid:36617530E4E4DE11B8C491C172E7EF12, uuid:13AB0963E3E4DE11B8C491C172E7EF12, uuid:BCF0AABBEDB511DC8066B832C59C5895, uuid:6BDBA096D17A11E086EF9BF99B73BE95, uuid:8B422310639F11DCAA68E4189C11ACA9, uuid:0F0DCC2769F5DA118718A238FC0FDA4D, uuid:EEC8F387D3AF11E0865CD5A3D4F0D622, uuid:3AC736E49D7E11E089009A499D74A604, xmp.iid:FD7F1174072068118F62ECC5B32F49CE, uuid:EEC8F387D3AF11E0865CD5A3D4F0D622, uuid:E910527F6E9F11DDA3B2ADC304BF948A, uuid:201E958E74E411DDA713DB46EF7A4B03
Manifest Reference Document ID  : uuid:4AE2BB68BC3311DC8E50B2F907B49664, uuid:E93F2EB8D0AC11E0858EF1F4BA54EE25, uuid:E93F2EB8D0AC11E0858EF1F4BA54EE25, uuid:A76C7463D09511E0858EF1F4BA54EE25, uuid:E93F2EB8D0AC11E0858EF1F4BA54EE25, uuid:C30265AAE3E4DE11B8C491C172E7EF12, uuid:12AB0963E3E4DE11B8C491C172E7EF12, uuid:BCF0AAB7EDB511DC8066B832C59C5895, uuid:6BDBA095D17A11E086EF9BF99B73BE95, uuid:8B42230A639F11DCAA68E4189C11ACA9, uuid:6689963F62F5DA118718A238FC0FDA4D, uuid:EEC8F386D3AF11E0865CD5A3D4F0D622, uuid:3AC736E39D7E11E089009A499D74A604, xmp.did:F77F1174072068118DBBEBFE67E765E2, uuid:EEC8F386D3AF11E0865CD5A3D4F0D622, uuid:E910527E6E9F11DDA3B2ADC304BF948A, adobe:docid:photoshop:a72b544e-4fd3-11d9-b6e8-831c8a170e5e, uuid:201E958D74E411DDA713DB46EF7A4B03
Metadata Date                   : 2011:09:26 07:53:15-04:00
Creator Tool                    : Adobe InDesign CS2 (4.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 8375 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Page Layout                     : SinglePage
Page Mode                       : UseOutlines
Page Count                      : 71
EXIF Metadata provided by EXIF.tools

Navigation menu