3119 Lx Belden 8471 Cable Cutsheet
2016-02-18
: Pdf 3119 Lx Belden 8471 Cable Cutsheet 3119_lx_belden_8471_cable_cutsheet spec products hba
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
Riser Rated Belden 8471 Cable LX SERIES NETWORKED LIGHTING CONTROLS PROJECT INFORMATION Project Name Catalog No. Date PVC Jacket (Unsheilded) Hubbell Controls' LX network cable is used to interconnect LX Panels, LX Devices and LX Accessories for a complete communications network. All devices that communicate on the LX Network are connected with the same type of twisted pair cable. Both power and data are carried over the same two wires. The LX System is wired as a topology-free, polarity-insensitive network. Hubbell Controls supplied LX Network Cables assure proper network communications and should be specified and installed on all LX System projects. BELDEN 8471 Twisted Pair #16 Tinned Copper Conductors, PVC Insulation PRODUCT FEATURES • • • • • • • • • • Interconnects LX Lighting Control Panels and LX network devices Cable carries both power and data in a single twisted pair Belden #8471 - twisted pair #16 tinned copper Single cable type connects to all types of LX network devices Echelon Guideline Compliant for LON networks Available in 100 ft and 500 ft reels Riser Rated Connects to terminal blocks or with twist on connectors UL and cUL Listed One-year limited warranty LX SYSTEM NETWORK CABLE REQUIREMENTS Hubbell Controls' LX Lighting Control System requires the use of Belden #8471 cable for Riser Rated applications OR Windy City Wire #104500 for Plenum Rated applications. These are the ONLY cables that can be used for network wiring with the LX System. The use of substitute cables based on similar physical characteristics is not allowed and will VOID any warranty for the LX system or any LX component connected to the substitute cable. General Specifications Description 1 pair - 16 AWG stranded tinned copper conductors, PVC Insulation, unshielded twisted pair (UTP), PVC jacket Shielding Unshielded Overall Nominal Diameter 0.274 inches Plenum Rating Not Plenum Rated Operating Temperature Range -20°C to +80°C (Indoor use only) Maximum Pulling Tension 61 lbs Minimum Bend Radius 5.1 inches Color Pair Color - Black/White, Outer Jacket - Gray Certifications NEC (UL) CMG, CEC/C (UL) CMG, Flame Test UL Flame Test – UL1685 FT4 Loading, C (UL) Flame Test FT4 Warranty One-year limited Ordering Information LX8471CBL100* LX8471CBL500* MODEL LX Cable Belden 8471 Riser Rated 100 ft Reel LX Cable Belden 8471 Riser Rated 500 ft Reel *All sales are final, no returns are allowed. INSTALLATION NOTES 1. DO NOT exceed 1500 feet of cable OR connect more than 56 devices per network segment. 2. Each network segment using LP style devices requires an LXLPM2 Link Power Module for device power. Each additional segment requires an additional LXLPM2 Link Power Module and an LXRRM Repeater for data transmission between segments. 3. Each network segment existing of panels only or that use FT style devices only require termination with LXTERMINATOR instead of LXLPM2 Link Power Module. 4. Run cable and connect network with the shortest distances possible. The most efficient network is wired similar to branch circuit outlets. 5. When using twist-on wire connectors with network cable use no more than three wires per connector. 6. The use of T-taps to minimize cable length is encouraged. Daisy chain topology is allowed, but most often increases overall cable length. 7. DO NOT homerun all devices individually, or leave spare cable at ceiling mounted devices. If devices need to be relocated, cables can be extended with twist-on wire connectors. 8. DO NOT mix plenum and NON-plenum cables on the same segment. 9. Keep 12” minimum from line voltage, do nut run in the same raceway with line voltage. 9601 Dessau Road | Building One | Austin, Texas 78754 | 512-450-1100 | 512-450-1215 fax | www.hubbell-automation.com 3119A 2.4.2016
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c111 79.158366, 2015/09/25-01:12:00 Create Date : 2016:02:04 11:21:32-06:00 Metadata Date : 2016:02:04 11:21:36-06:00 Modify Date : 2016:02:04 11:21:36-06:00 Creator Tool : Adobe InDesign CC 2015 (Windows) Instance ID : uuid:52285229-989d-44f9-8f91-dc6786f17a26 Original Document ID : adobe:docid:indd:cfbfb411-e39d-11e0-8667-d1d86aa20b67 Document ID : xmp.id:4d10be41-bff6-0241-830b-21738dc4fb80 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:4b812f25-7584-7d4a-9651-e96557fd80d9 Derived From Document ID : xmp.did:4050B8E20982E3119529CDFDE2FCEF68 Derived From Original Document ID: adobe:docid:indd:cfbfb411-e39d-11e0-8667-d1d86aa20b67 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Windows) History Changed : / History When : 2016:02:04 11:21:32-06:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CC 2015 (Windows)EXIF Metadata provided by EXIF.tools