TS450 UserGuide 31715003 TRACE 1300 Series GC User Guide
2016-05-17
: Pdf 31715003 Trace 1300 Series Gc User Guide 31715003 TRACE 1300 Series GC User Guide TRACE 1300 TRACE 1310 GC AS Manuals User ation
Open the PDF directly: View PDF
Page Count: 384 [warning: Documents this large are best viewed by clicking the View PDF Link!]
- Contents
- Preface
- Getting Familiar with Your TRACE 1300/TRACE 1310
- TRACE 1310 User Interface
- TRACE 1310 User Interface Overview
- Configuring the Instrument
- Oven Menu
- Back and Front Inlet Menu
- Back, Front, Aux L, and Aux R Detector Menu
- Analog Output Interface Menu
- Back and Front Column Menu
- Performing Column Evaluation
- Handshaking Menu
- Time/Units Menu
- Touch Screen Menu
- Network Menu
- Valve Oven Menu
- Aux Left and Right Detectors Menu
- Auxiliary Carrier Menu
- Auxiliary Temperature Menu
- Auxiliary Column Menu
- Creating a Method
- Monitoring the Instrument Status
- Monitoring the Signal Level
- Performing a Diagnostic
- Performing a Maintenance
- TRACE 1300 User Interface
- Configuration and Method Parameters Setup from CDS
- Introduction
- Configuration General Tab
- Configuration Handshaking Signals
- Configuration Inlets Tab
- Configuration Detectors Tab
- Configuration Aux Oven (Valve Oven)Tab
- Configuration Auxiliary Temperature Tab
- Configuration Auxiliary Carrier Tab
- Edit Method Parameters
- Oven Page
- S/SL Page
- S/SL Backflush Page
- PTV Page
- PTV Backflush Page
- GSV Page
- Helium Saver (HeS-S/SL) Page
- FID Page
- ECD Page
- NPD Page
- TCD Page
- FPD Page
- PDD Page
- GDI Page
- Auxiliary Temperature Page
- Auxiliary Carrier Page
- Run Table Page
- Run-Time Event
- Oven
- Split/Splitless Injector (SSL) Module
- Split/Splitless Backflush Injector (SSLBKF) Module
- Gas Sampling Valve (GSV) Module
- Instant Connect Helium Saver Injector Module (HeS-S/SL)
- Programmable Temperature Vaporizing Injector (PTV) Module
- Module Overview
- Injection Techniques
- Consumables
- Using PTV Parameters
- Carrier Gas Parameters
- Injection Mode
- Inlet Parameters
- Purge Parameters
- Surge Parameters
- Injection Phases Parameters
- Setting Gas Parameters
- Setting Parameters for PTV Split Mode
- Setting Parameters for PTV Splitless Mode
- Setting Parameters for PTV Large Volume Mode
- Programming Injection Parameters
- Setting Parameters for CT Split Mode
- Setting Parameters for CT Splitless Mode
- Setting Parameters for CT Surged Splitless Mode
- Programmable Temperature Vaporizing Backflush Injector (PTVBKF) Module
- Flame Ionization Detector (FID) Module
- Nitrogen Phosphorus Detector (NPD) Module
- Thermal Conductivity Detector (TCD) Module
- Electron Capture Detector (ECD) Module
- Flame Photometric Detector (FPD) Module
- Instant Connect Pulsed Discharge Detector (PDD)
- Generic Detector Interface (GDI)
- Analog Output Interface (AOI) Module
- Optional Modules
- Starting Analysis
- Analytical Troubleshooting
- Investigating Baseline Issues
- Investigating Peak Issues
- Investigating Results Issues
- SSL, SSLBKF, and HeS-S/SL Analytical Troubleshooting
- PTV and PTVBKF Analytical Troubleshooting
- Discrimination of heavy compounds in splitless mode.
- Discrimination of volatile compounds.
- Discrimination of volatile compounds in splitless mode.
- Discrimination of volatile compounds in large volume mode.
- Discrimination split mode.
- Excessive broadening of the solvent peak.
- Volatile compound obscured.
- Lack of sensitivity.
- Sample degradation.
- Poor reproducibility of results.
- Backflush analytical troubleshooting
- FID Analytical Troubleshooting
- NPD Analytical Troubleshooting
- TCD Analytical Troubleshooting
- ECD Analytical Troubleshooting
- FPD Analytical Troubleshooting
- PDD Analytical Troubleshooting
- GDI Analytical Troubleshooting
- Glossary