SureLites_wpc:Surelites

2014-06-02

: Pdf 376390-Attachment 376390-Attachment 662400 Batch4 unilog

Open the PDF directly: View PDF PDF.
Page Count: 116

DownloadSureLites_wpc:Surelites
Open PDF In BrowserView PDF
SURE-LITES

®

Exit and Emergency Lighting

EMERGENCY LIGHTS
EXIT SIGNS
ALL PRO EMERGENCY
INDUSTRIAL & HAZARDOUS
RETROFIT
ACCESSORIES
CHICAGO CODE
LIGHTING INVERTERS

EXIT SIGNS

SURE-LITES

®

EMERGENCY
LIGHTING

EMERGENCY LIGHTS
EXIT SIGNS
ALL PRO EMERGENCY
INDUSTRIAL & HAZARDOUS
RETROFIT
ACCESSORIES
CHICAGO CODE
LIGHTING INVERTERS

SURE-LITES

The TRUSTED name for emergency lighting

Offering a COMPREHENSIVE LINE of emergency lights, exit signs,
lighting inverters, and retrofit products. A full range of INNOVATIVE
SOLUTIONS are available from routine COMMERCIAL to upscale
ARCHITECTURAL to hazardous INDUSTRIAL locations.

ALL products are UL 924 LISTED and comply with
THE LIFE SAFETY CODE (NFPA 101).

In addition, a complete line of ENERGY EFFICIENT products are
available to significantly reduce energy consumption and exceed
conservation standards.

Thinking ahead, a DEDICATED engineering group
focuses on advanced technology to continue
developing more effective ways to provide
emergency lighting.

®

SURE-LITES

- RELIABILITY GUARANTEED.

INTRODUCTION

®

INTRODUCTION

EMERGENCY
LIGHTS

INTRODUCTION

EXIT SIGNS

< TABLE OF CONTENTS >

EMERGENCY LIGHTS
ARCHITECTURAL

AEL Series
p. 8

CHEL Series
p. 9

MML Series
p. 10

ML Series
p. 11

RD Series
p. 12

RLM Series
p. 12

GC Series
p. 13

SLC Series
p. 14

P4C Series
p. 15

RG Series
p. 16

C7213EEMSL
p. 17

H274EM
p. 18

StairLite
p. 19

StairLite 2
p. 20

CC2 Series
p. 21

CC3, 4, 5, 6 Series
p. 22

CC7 Series
p. 23

CC8 Series
p. 24

CC9, 10, 11, 12 Series
p. 25

CU1 Series
p. 26

CU2 Series
p. 27

XR Series
p. 28

HR Series
p. 29

HS1R Series
p .30

LM1 Series
p. 31

AA1 Series
p. 32

6V, 12V Plastic
Weatherproof

6V, 12V Metal Head

6V, 12V Metal Head6V, 12V MR16
Weatherproof
p. 35

MR (Metrolite)

CFR Series

p. 34

p. 35

p. 36

Ultimate Remote
Head Series

HZB/HZP Series

COMMERCIAL

REMOTE

6V, 12V Plastic
p. 33

p. 33

p. 34

DR Series

CU Series

GFR Series

R4C Series

RFR Series

p. 36

p. 36

p. 36

p. 37

p. 37

p. 37

p. 37

< TABLE OF CONTENTS >

EXIT SIGNS
ARCHITECTURAL

ELX-AC Series

ELX-SP Series

ES Series

CX Series

CAX Series

TPX Series

CAR Series

p. 38

p. 39

p. 40

p. 41

p. 42

p. 46

p. 48

CCX Series
p. 52

EEX Series
p. 55

EU Series
p. 56

INCX Series
p. 58

SLX Series
p. 59

R/G/OF/PLX Series
p. 60

COMMERCIAL

LPX Series
p. 50

UN/UNH/PLX Series
p. 61

ALL PRO

APSSQ Series
p. 63

AP60/70 Series
p. 64

AP70..DH Series
p. 65

< TABLE OF CONTENTS >

INDUSTRIAL &
HAZARDOUS LOCATIONS

UEL Series
p. 66

NCB Series
p. 67

UMB Series
p. 68

TRX Series
p. 73

PHL Series
Photoluminescent
p. 74

HZX Series
p. 75

HZU1254 Series
p. 69

UX Series
p. 70

UMX Series
p. 71

VRX Series
p. 72

RETROFIT

FBP

LTC

LTC2

RKRC, RKRI

REM, RBP

277 CONVERSION

FTBR CONVERSION

p. 76

p. 77

p. 78

p. 79

p. 80

CANOPY
p. 81

CANOPY
p. 81

EMERGENCY POWER
PACK
p. 82

CAX EMERGENCY
POWER PACK
p. 82

Polycarbonate
Shield

Wire Guards

Pendant Kits

Canopy Kits

p. 83

p. 83, 84

p. 84

p. 83

Cord Sets
p. 85

Mounting Brackets,
Mounting Shelves

Recessing Kits
p. 86

p. 86

CAX Series Splice
Box

Switching
Accessories

Remote Test Swith
& Pilot Light

p. 84

p. 85

p. 85

Tamper Proof Screws
& Screwdriver Bits
p. 86

CHICAGO CODE

UEL Series

CHEL Series

XR Series

HR Series

GC Series

ST1 Series

FBP Series

p. 87

p. 88

p. 89

p. 90

p. 91

p. 92

p. 93

CHX Series

EAC Series

p. 94

p. 96

LIGHTING INVERTERS

Micro Inverter SeriesLifeway II Single
p. 98
Phase IPS Series
p. 99

Lifeway II Single
Phase C Series
p. 100

Lifeway II Three
Phase Series
p. 101

< TABLE OF CONTENTS >

ACCESSORIES

Architectural

EMERGENCY LIGHTS >

SURE-LITES®
DESCRIPTION

ARCHITECTURAL
EMERGENCY
LIGHT SERIES
DIE CAST ALUMINUM
EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz

DIMENSIONS

> Die cast aluminum housing
with powder coat finish

> Watchguard EMS
Self-Diagnostic System

[276.23mm]
3 7/8”
[98.43mm]

7”
[177.8mm]

Self-Diagnostics

The self-diagnostic unit will automatically perform the
tests required by the NFPA 101 Life Safety Code. The
system indicates the status of the unit at all times using
an LED indicator that is located near the test switch.

Verify proper operation of the
transfer circuit and emergency
lamps with a convenient laser
pointer (sold as an accessory).

> Three 6V, 6W High output
Xenon lamps
> Sealed Nickel Cadmium
Battery Maintenance Free,
Long Life, Full Recharge
time, 24 Hours

10 7/8”

The Architectural Emergency
Light is designed to provide superior illumination while blending
into the surrounding space. The
housing is constructed of die cast
aluminum with an integral refractive polycarbonate lens. The
emergency light’s advanced optical design in conjunction with
high output Xenon lamps provide
maximum path of egress lighting
performance. The Sure-Lites
Architectural Emergency Light is
listed for temperatures between 20°C and 40°C (-4°F and 104°F)
and has silicone gaskets that provide protection from moisture
and rain. [Remote unit temperature range: -40°C and 65°C (-40°F
and 149°F)] Standard features
include Watchguard EMS selfdiagnostic system which meets
NFPA 101 testing requirements
and a FasTest photocell which
enables remote testing of the
emergency light.

E L E C T R I C A L R AT I N G S

Lamp Information

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model

DC Voltage

1 1/2 Hours

Type

Wattage

Number

Spacing1

AEL1SD

6

18

Xenon

6 each

11549423

30.0'

> Photocell Test Switch
(requires accessory LASER
for activation)
> Universal Pattern
Knockouts on rear of
housing for direct
mounting to junction box
> UV Stable Polycarbonate
Lens
> Line-Latching, Solid-state
Voltage Limited Charger,
Low-Voltage Disconnect,
Brownout Circuit,
Overload/Short Circuit
Protection, Test
Switch/Power Indicator
Light
> UL Outdoor Wet/Damp
Location Listed
> UL 924 Listed SelfDiagnostics, Life Safety
NFPA 101, NEC/OSHA, Most
State and Local Codes

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: AEL1SD

Family
AEL1=Architectural
Emergency
Light

COOPER LIGHTING

Housing
Finishes
Blank=Silver
BK=Black
BZ=Bronze
WH=White

SD=Self Diagnostics
(Standard)

Options
TDM=Time Delay
Monitor
Remote=Remote
Unit

Accessories
(order separately)
LASER=Key Chain, Red Laser
Pointer (activation tested at 15 feet)

E N E R G Y D ATA

AEL1SD
Input Current (Max.)
120V = .10A
277V = .07A

1The

8

SD

AEL1

AEL1WHSD

AEL1BKSD

AEL1BZSD

"Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress.
The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 8.5 feet. Cooper Lighting assumes no responsibility
for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.

DESCRIPTION

DIMENSIONS
11.5”

4.0”

[292mm]

[102mm]

6.5”
[165mm]

CHEL SERIES
DIE CAST ALUMINUM

Architectural

The CHEL Emergency Light
provides a distinct solution
to any emergency lighting
application. Constructed of die
cast aluminum, the CHEL
presents not only a unique
shape and design but also
provides dependable strength
and durability. The two, fully
adjustable, high efficiency
12W, MR16 lamps provide
maximum path of egress
performance. The standard
Watchguard EMS self-diagnostic system meets NFPA 101
testing requirements providing assurance that the unit is
working properly at all times.
The Sure-Lites FASTEST
LASER test feature allows
remote, 30 second testing of
the emergency light.

EMERGENCY LIGHTS >

SURE-LITES®

EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz
> Die cast aluminum
housing with powder
coat finish

Self-Diagnostics

The self-diagnostic unit will automatically perform the
tests required by the NFPA 101 Life Safety Code. The
system indicates the status of the unit at all times using
an LED indicator that is located near the test switch.

> Two Fully adjustable heads
with 6V, 12W MR16 lamps

Verify proper operation of the
transfer circuit and emergency
lamps with a convenient laser
pointer (sold as an accessory).

> Sealed Lead Calcium
Battery Maintenance Free,
Long Life, Full Recharge
time, 24 Hours

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage

> Watchguard EMS SelfDiagnostic System

Lamp Information

Model

DC Voltage

1 1/2 Hours

Type

Wattage

Number

Spacing1

CHEL1SD

6

24

MR16

12

29-140

50.0'

> Remote Photocell Test
Switch (requires accessory
LASER for activation)
> Universal Pattern
Knockouts on rear of
housing for direct
mounting to junction box

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: CHEL1SD

> Snap Fit Design

SD

CHEL1

> Reversible Mounting
Family
CHEL1=Architectural
Emergency
Light

Housing
Finishes
Blank=Silver
BK=Black
WH=White

SD=Self Diagnostics
(Standard)

Options
TDM=Time Delay
Monitor

Accessories
(order separately)
LASER=Key Chain, Red Laser
Pointer (activation tested at 30 feet)

> Line-Latching, Solid-state
Voltage Limited Charger,
Low-Voltage Disconnect,
Brownout Circuit,
Overload/Short Circuit
Protection, Test
Switch/Power Indicator
Light
> UL Damp Location Listed
> UL 924 Listed SelfDiagnostics, Life Safety
NFPA 101, NEC/OSHA,
Most State and Local
Codes

E N E R G Y D ATA

CHEL1SD
Input Current (Max.)
120V = .05A
277V = .02A

CHEL1BKSD

CHEL1WHSD

CHEL1SD
(Reverse Mounted)

1The

"Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress.
The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.5 feet. Cooper Lighting assumes no responsibility
for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.

COOPER LIGHTING

9

DESCRIPTION

The Metrolite MML Series has a sculptured and compact appearance that makes it perfect for quality
interior applications. The self-contained, feature rich design packs a powerful punch with its superbright halogen lamp and precision optics. The integral mounting plate makes installation fast and
easy.

EMERGENCY LIGHTS >

Architectural

SURE-LITES®

DIMENSIONS

MML SERIES

METROLITE
EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz
> Injection-Molded, HighImpact, Thermoplastic
Housing, Rated UL 94-5VA,
Designer-White Textured
Finish, Integral Mounting
Plate
> Glare Free Lens, Fully
Adjustable, Halogen
Lamps
> Sealed Lead Calcium
Battery Maintenance Free,
Long Life, Full Recharge
time, 24 Hours (max.)
> Line-Latching,
Low-Voltage Disconnect,
Test Switch, AC Power
Indicator, Brownout Circuit

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2 % of Rated D.C. Voltage
Model

DC Voltage

1 1/2 Hours

Type

Wattage

Number

MML1
MML2

4
4

4.8
9.6

Tungsten Halogen
Tungsten Halogen

4.8W
4.8W ea

L010777
L010777

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER:

MML1

> UL 924, Life Safety NFPA
101, NEC/OSHA, Most
State and Local Codes
Model Number
MML1
MML2

E N E R G Y D ATA

Input Current (Max.)
MML1
120V = .037A
277V = .019A
MML2
120V = .074A
277V = .038A

10

COOPER LIGHTING

Lamp Information

Accessories
(Order separately)
VS1 = Polycarbonate Vandal Shield
WG8 = Wire Guard MML1
WG9 = Wire Guard MML2

DESCRIPTION

The Metrolite ML Series is the right choice for installations where aesthetics are a priority. With its
white finish and sculptured compact design the product blends in with the surroundings. Matching
remotes are available to insure a consistent appearance. The pleasing look is accompanied by a feature rich design that provides fully adjustable heads with high efficiency halogen lamps making it
easy to direct ample light to the required areas. Each unit employs a quick mount universal back with
hinged access for hassle free installation.

DIMENSIONS

Architectural

ML SERIES
METROLITE

EMERGENCY LIGHTS >

SURE-LITES®

METROLITE
EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2 % of Rated D.C. Voltage
Model

DC Voltage

ML1
ML2
ML3
ML4NC
ML5NC

6
6
12
6
12

1 1/2 Hours
25
50
50
14
28

Lamp Information
Remote Wattage Available
0
26
26
0
0

Type
Bi-Pin Halogen
Bi-Pin Halogen
Bi-Pin Halogen
Bi-Pin Halogen
Bi-Pin Halogen

Wattage
12W ea
12W ea
12W ea
6W ea
12W ea

Number
029-66
029-66
029-45
029-12
029-45

> Injection-Molded, HighImpact, Thermoplastic
Housing, Rated UL 94-5VA,
Designer-White Textured
Finish, Integral Mounting
Plate
> Glare Free Lens, Fully
Adjustable, Halogen
Lamps
> Sealed Lead Calcium or
Nickel Cadmium Battery
Maintenance Free, Long
Life, Full Recharge time,
24 Hours (max.)

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER:

Model Number
ML1
ML2
ML3
ML4NC1
ML5NC1

ML1

Options (add as suffix)
V = Voltmeter
TDM= Time Delay Monitor
Alternate Lamps2

Accessories
(Order separately)
VS1 = Polycarbonate Vandal Shield
WG12 = Wire Guard

> Line-Latching,
Low-Voltage Disconnect,
Test Switch, AC Power
Indicator, Brownout Circuit
> Red LED High Charge
Indicator, Amber LED AC
Power Indicator
> UL 924, Life Safety NFPA
101, NEC/OSHA, Most
State and Local Codes

E N E R G Y D ATA

Input Current (Max.)
ML1, ML2, ML3
120V = .3A
277V = .1A
ML4NC, ML5NC
120V = .085A
277V = .035A

1NC

= Nickel Cadmium Battery. 2Consult your Cooper Lighting Representative.

COOPER LIGHTING

11

Architectural

EMERGENCY LIGHTS >

SURE-LITES®
DIMENSIONS

DESCRIPTION

RD SERIES
Tw o I n j e c t i o n M o l d e d
T h e rm o p l a s t i c H e a d s

The RD Series is a recessed
emergency lighting system
designed for locations
where aesthetics are of
utmost importance. The
housing is fully recessed in
dry wall or grid ceiling
installations. Designer
pinchback heads rotate 358°
and swivel 90° to 0°. Ideal
for commercial and institutional environments where
easy recessed installation
and minimal maintenance
are desired.
The RLM Series is a
recessed system packaged
in an attractive flame-resistant metal housing. It is the
unit of choice for installations where a recessed
product is desired and the
size and cost of emergency
lighting must be kept to a
minimum without sacrificing
dependability or light output.

RLM SERIES
E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of rated D.C. Voltage
Tw o H i g h - I m p a c t
T h e rm o p l a s t i c H e a d s
EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz
> 20 gauge die-formed
steel housing with white
powder coat finish
> Heads match housing
finish

Model

Battery

DC Voltage

1 1/2 hours

2 hours

3 hours

RD1
RD3
RD4
RD6
RD7
RLM1
RLM2
RLM3
RLM4
RLM8
RLM9

SLC
SLC
SLC
SNC
SNC
SLC
SLC
SLC
SLC
SNC
SNC

6
6
12
6
6
6
6
6
12
6
6

18
27
54
15
24
10.8
18
27
54
15
24

15
24
12
18
7.2
15
24
12
18

10
18
8
12
10
18
8
12

Lamp Information
4 hours Type
8
14
6
10
8
14
10

SLC=Sealed Lead Calcium Battery
SNC=Sealed Nickel Cadmium Battery

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: RD1V

> Ceiling or wall mounting
> Supplied with hanger bars,
T-Bar clips
> Single modular electrical
connector
> Remote capability
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low- voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test switch/
power indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

12

COOPER LIGHTING

Model Number
RD1
RD3
RD4
RD6
RD7
RLM1
RLM2
RLM3
RLM4
RLM8
RLM9

Options
(Add as suffix)
A=Ammeter 1
SD=Self-Diagnostics
TDM=Time Delay Monitor
V=Voltmeter 1
Alternate Lamps2
Other Options 2

Accessories
(Order separately)
WG2 =Wire Guard
WG7 =Wire Guard
VS=Choose polycarbonate
vandal shield desired
from accessories
sheet

Energy Data

Model No.
RD1, RD3
RD4, RLM4
RD6
RD7
RLM1, RLM2, RLM3
RLM8
RLM9
1Provision

Input Current (Max.):
120V
277V
.12A
.05A
.30A
.13A
.06A
.03A
.07A
.04A
.12A
.05A
.06A
.03A
.07A
.04A

for one meter only. 2Consult your Cooper Lighting Representative.

Tungsten Halogen
Tungsten Halogen
Incandescent
Tungsten Halogen
Tungsten Halogen
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent

Wattage
6
12
9
6
12
5.4
9
9
9
7.2
7.2

Number
29-12
29-66
029-86
29-12
29-66
29-121
29-84
29-84
029-86
29-88
29-88

DESCRIPTION

DIMENSIONS

GC SERIES
Recessed Housing
Suspended Ceiling

Architectural

The GC Series combines a
clean, sleek, contemporary
appearance with state-of-the-art
electronics. Specifically
designed for initial and retrofit
installations where a recessed
unit is desired to maximize aesthetics. The unit is ideal for
locations with limited wall
space and where panoramic
positioning is necessary for the
ceiling mounted lampholders to
provide proper light distribution. Ideal for stores, offices,
hospitals and school corridors.

EMERGENCY LIGHTS >

SURE-LITES®

EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of rated D.C. Voltage
Model
GC15012
GC15022
GC15032
GC15042
GC15052
GC15122
GC15132
GC15142
GC15172
GC15182

Battery
SLC
SLC
SLC
SLC
SLC
SNC
SNC
SNC
SNC
SNC

DC Voltage
6
6
6
12
12
6
6
6
12
12

1 1/2 hours

2 hours

3 hours

27
54
85
36
54
15
24
48
30
48

24
48
66
30
48
12
18
36
24
36

18
36
50
20
36
8
12
24
16
24

Lamp Information
4 hours Type
14
28
40
16
28
6
10
20
12
20

Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent

SLC=Sealed Lead Calcium Battery
SNC=Sealed Nickel Cadmium Battery

S A M P L E N U M B E R : G C 1 5 01 2 C L

Options
(Add as suffix)
A=Ammeter
CL=Cylinder Heads
DR=Halogen Pinchback Designer
Heads
SD=Self-Diagnostics (GC15012,
GC15042, GC15052,
GC15122, GC15132,
GC15172, GC15182, Only)
TDM=Time Delay Monitor
V=Voltmeter
Alternate Lamps 1
Other Options 1

Number

9
9
9
9
9
7.2
7.2
7.2
9
9

29-84
29-84
29-84
29-86
29-86
29-88
29-88
29-88
29-86
29-86

> 20 gauge die-formed
steel housing with white
powder coat finish
> Two high-impact, fully
adjustable thermoplastic
heads
> Flanged for mounting in
grid-type suspended
ceilings
> Above ceiling access
required for maintenance

O R D E R I N G I N F O R M AT I O N

Model Number
GC15012
GC15022
GC15032
GC15042
GC15052
GC15122
GC15132
GC15142
GC15172
GC15182

Wattage

> Single modular electrical
connector
Accessories
(Order separately)
VK1 =Voltmeter
WG12 =Wire Guard
WG17 =Wire Guard for use
with CL heads

> Remote Capability
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low- voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

Energy Data

Model No.
GC15012, GC15022, GC15032
GC15042, GC15052
GC15122
GC15132
GC15142
GC15172
GC15182

1Consult

Input Current (Max.):
120V
277V
.12A
.05A
.30A
.13A
.06A
.03A
.07A
.04A
.08A
.05A
.13A
.06A
.15A
.07A

your Cooper Lighting Representative.

COOPER LIGHTING

13

DIMENSIONS

DESCRIPTION

The SLC Series is a solid-state,
self-contained emergency lighting
system. The architecturally
designed heads blend perfectly
with the most sophisticated decor.

EMERGENCY LIGHTS >

Architectural

SURE-LITES®

SLC SERIES
Large Cylinder Head(s)
EMERGENCY LIGHT

E L E C T R I C A L R AT I N G S - S E A L E D L E A D C A L C I U M B AT T E R Y

Rated Wattage to 87 1/2% of rated D.C. Voltage
Model

> Dual-voltage input
120/277VAC, 60Hz
> 18 gauge die formed
steel housing with white
powder coat finish
> Single or double front
mounted white
thermoplastic fully
adjustable heads with
glare free lens

SLC1
SLC1H
SLC2
SLC2H
SLC120
SLC120H
SLC220
SLC220H

Battery

No. of Heads

DC Voltage

1 1/2 hours

SLC
SLC
SLC
SLC
SNC
SNC
SNC
SNC

1
1
2
2
1
1
2
2

6
6
6
6
6
6
6
6

10.8
27
18
54
8
24
15
48

2 hours

Lamp Information
3 hours 4 hours

7.2
24
15
48
18
12
36

SLC=Sealed Lead Calcium Battery
SNC=Sealed Nickel Cadmium Battery

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: SLC1V

> Remote capability
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test
switch/power indicator
light

Model Number
SLC1
SLC1H
SLC2
SLC2H
SLC120
SLC120H
SLC220
SLC220H

Options
(Add as suffix)
A=Ammeter 2
TDM=Time Delay Monitor
V=Voltmeter2
Alternate Lamps1
Other Options1

Accessories
(Order separately)
WG5=Wire Guard
(1 Head)
WG6=Wire Guard
(2 Heads)

> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes
Energy Data

Model No.
SLC1
SLC1H, SLC2, SLC2H
SLC120
SLC120H
SLC220
SLC220H

1Consult

14

COOPER LIGHTING

Input Current (Max.):
120V
277V
.08A
.04A
.12A
.05A
.05A
.03A
.07A
.04A
.06A
.03A
.08A
.05A

your Cooper Lighting Representative. 2Provision for one meter only.

18
10
36
14
8
28

14
8
28
10
6
20

Type
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent

Wattage

Number

9
9
9
9
7.2
7.2
7.2
7.2

29-84
29-84
29-84
29-84
29-88
29-88
29-88
29-88

DIMENSIONS

DESCRIPTION

P4C SERIES
Decorative Square

Architectural

The P4C Series is a decorative,
mini-system that features
solid-state electronics and a
long-life maintenance free
battery. It is designed for
surface mounting but may be
semi-recessed or fully recessed
by using a field-installed
recessed kit. The diffused
tungsten halogen light source
and reliable electronics make
the P4C Series ideal for
illuminating corridors, stairways, doorways, and offices.

EMERGENCY LIGHTS >

SURE-LITES®

EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz
> Black thermoplastic body
with white plastic collar
and reflector

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of rated D.C. Voltage
Model

Battery

DC Voltage

1 1/2 hours

P4C1
P4C2
P4C223
P4C3
P4C6
P4C7
P4C723

SLC
SLC
SLC
SLC
SNC
SNC
SNC

6
6
6
6
6
6
6

10.8
27
27
54
15
24
24

2 hours
7.2
24
24
48
12
18
18

3 hours
18
18
36
8
12
12

Lamp Information
4 hours Type
14
14
28
6
10
10

Bi-Pin Halogen
Bi-Pin Halogen
Bi-Pin Halogen
Bi-Pin Halogen
Bi-Pin Halogen
Bi-Pin Halogen
Bi-Pin Halogen

SLC=Sealed Lead Calcium Battery
SNC=Sealed Nickel Cadmium Battery

Wattage

Number

10
10
10
10
10
10
10

29-40
29-40
29-40
29-40
29-40
29-40
29-40

> High-impact acrylic lens
with test switch behind
flexible lens
> Universal J-Box mounting
pattern with 1/2” conduit
knockouts
> Surface mounting,
recessed or semi-recessed

O R D E R I N G I N F O R M AT I O N

> Wall or Ceiling mounting

SAMPLE NUMBER: P4C1PCL

> Remote capability
Model Number
P4C1
P4C2
P4C22
P4C3
P4C6
P4C7
P4C72

Options
(Add as suffix)
PCL=Polycarbonate Lens
TDM=Time Delay Monitor
V=Voltmeter 2
A=Ammeter2
Other Options 1

Accessories
(Order separately)
WG7 =Wire Guard
USF1=Rough-in Kit for semi-recessed
installation 8 1/4"L x 8 1/4"W x 2 7/8"D
(210mm x 210mm x 73mm)
FRK1=Rough-in Kit for fully recessed
installation 9 1/8"L x 9 1/8"W x 5 1/8"D
(232mm x 232mm x 130mm)
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield Weatherproof

> Line-latching, Solid-State
voltage limited charger,
Solid-State switching, lowvoltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

Energy Data

Input Current (Max.):
Model No.
120V
277V
P4C1, P4C2, P4C22, P4C3 .12A
.05A
P4C6
.06A
.03A
P4C7, P4C72
.07A
.04A

1Consult

your Cooper Lighting Representative. 2Only one meter - not compatible with FRK-1. 3 Twin Lamps.

COOPER LIGHTING

15

Architectural

EMERGENCY LIGHTS >

SURE-LITES®
DIMENSIONS

DESCRIPTION

RG SERIES
Recessed Gimbal

Perfect for commercial or
architectural applications
where the aesthetics of a fully
recessed unit are essential.
The slim profile of the RG
Series is ideal for low ceilings
and blends inconspicuously
with existing recessed installations. The gimbal mounted
lamp provides directional aiming (optional white gimbal ring
offers the perfect blend for
suspended ceilings). The RG
Series combines a high output
sealed beam type lamp, sealed
lead calcium battery and full
feature Sure-Lites electronics.

EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz
> Fixture illuminates upon
loss of AC power
(normally off)
> 20 gauge die-stamped
steel housing
> Polycarbonate lens
included
> Adjustable aiming angle
30°
> Hanger bars accommodate
24" spans and can be
rotated 90° on plaster
frame

E L E C T R I C A L R AT I N G S - S E A L E D L E A D C A L C I U M B AT T E R Y

Rated Wattage to 87 1/2% of rated D.C. Voltage
DC Voltage 1 1/2 hours

2 hours

3 hours

4 hours

Type

Wattage

Number

RG1

6

10.8

7.2

-

-

Incandescent

9

29-84

RG2

6

27

24

-

-

Incandescent

25

29-09

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: RG1WH

> Conduit knockouts, four
1/2" and two 3/4"
> Trim ring, with integral test
switch, held in place with
torsion springs

Model Number
RG1
RG2

> Standard white trim ring/
black gimbal ring
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low- voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test switch/
power indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
CSA Certified, most state
and local codes

Options
(Add as suffix)
BK=Black Trim Ring/Black
Gimbal Ring
WH=White Trim Ring/White
Gimbal Ring
Alternate Lamps 1
Other Options 1

Energy Data

Model No.
RG1

Input Current (Max.):
120V
277V
.12A
.05A

RG2

.12A

.05A

> IC Rated

16

COOPER LIGHTING

Lamp Information

Model

1Consult

your Cooper Lighting Representative.

Accessories
(Order separately)
WG1=Wire Guard

DESCRIPTION

The C7213EEMSL wide beam downlight features a completely self-contained battery-operated emergency lighting system utilizing energy saving compact fluorescent lamps. This unit provides inconspicuous emergency lighting by blending with Portfolio downlights. It’s designed to provide normal illumination with AC power and 90 minutes of emergency lighting. The fixture may be installed in switched circuits. The battery charge indicator light and test switch are prewired to a quick connect modular plug
which also makes the final battery connection for energizing the circuit.

DIMENSIONS

DESCRIPTION

Lamp:

7 3/8

C7213EEMSL

13W 4 Pin Quad

Lamp and Lamp Image Cutoff: 55°

Architectural

Aperture Size:

EMERGENCY LIGHTS >

SURE-LITES®

Recessed/Fluorescent
Aperture: 7 3/8" (187mm)
Cutout: 8 1/8" (206mm)
OD: 8 3/4" (222mm)

EMERGENCY LIGHT

> Dual voltage input 120V
through 277VAC, 50/60 Hz
> Die cast aluminum 1 1/2"
deep collar

O R D E R H O U S I N G , T R I M A N D A C C E S S O R I E S S E PA R AT E LY, L A M P S U P P L I E D B Y O T H E R S

> One piece Alzak reflector
with spun parabolic
contour provides 55° cutoff
to lamp and lamp image

C7213EEMSL

> All finishes are low
iridescent to eliminate
rainbowing

Housing
C7213EEMSL=7 3/8" 13W
(2) Lamp
120V through 277V

Trims
7250=Reflector
with Polymer
Trim
7251=Self Flanged
Reflector

Finish1
LI=Low Iridescent
H=Haze
S=Straw
WH=Wheat
BB=Black Baffle
(on 7250 only)
WB=White Baffle
(on 7250 only)

Accessories2
(Order separately)
Trim Rings
TRM7P=White Metal
TRM7MB=Black Metal
TRR7=Rimless
Slope Ceiling Adapter
HSA7XX=Specify Slope
1 1/2" C-Channel Bar
Hangers
HB26=26" Long
HB50=50" Long

> Sealed nickel cadmium
battery
> Exclusive universal
mounting bracket
adjusts 5" vertically
> Junction box with 1/2"
and 3/4" pryouts, listed
for eight #12g 90°C
conductors
> Electronic ballasts have
integral fuse, >99% power
factor and <10%THD.
Electronic ballasts have
current controlled preheat
starting and End of Life
protection standard.
> Solid state voltage limited
charger, overload short
circuit protection, test
switch/power indicator
light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

1For White Painted Flange (on self flanged reflectors) add WF to Reflector Finish.
2Accessories should be ordered separately. For additional options please consult your Cooper Lighting Representative.

COOPER LIGHTING

17

Architectural

EMERGENCY LIGHTS >

SURE-LITES®
DIMENSIONS

DESCRIPTION

H274EM
Recessed/Fluorescent
EMERGENCY LIGHT

The H274EM uses one 13W
compact fluorescent lamp
(DTT, 2-Pin) in a H274 fixture.
It matches the Halo H274
downlight in appearance and
will automatically provide 120
minutes of emergency power.
Typically, the H274EM would
be installed on a 24 hour circuit but can also be installed
on switched circuits (277V
unswitched circuits require the
EMS277 accessory). The battery charge indicator light and
test switch are prewired to a
quick connect modular plug
which also makes the final battery connection for energizing
the circuit.

> Dual-voltage input
120/277VAC, 60Hz
> 20 gauge die-stamped
steel housing with white
baked enamel finish
> Accommodates all
recommended trims
> Adjustable socket plate
> Initial 900 lumens in
emergency mode

O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : H 2 74 E M

H274EM
Model Number
H274EM

> Hanger bars span 24"
and can be rotated 90°
on plaster frame
> Junction Box has five 1/2"
trade size knockouts with
true pry-out slots
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low- voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light

Trims
(Order separately)
400RG=Residential Gold Satin
Reflector
400SC=Specular Clear Finish
Reflector
405CG=Champagne Gold
Specular Reflector
405RG=Residential Gold
Specular Reflector
405SC=Clear Specular Reflector
409P=Reflector with Black
Coilex Baffle

Energy Data

Model No.
H274EM (Starting)
H274EM (Operating)

Input Power
120V
277V
30W
34W
19W
21W

> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

18

COOPER LIGHTING

Accessories
(Order separately)
EMS277=Accessory for 277V
Switching Applications
TRM7P=White Metal Trim Ring
TRM7MB=Black Metal Trim Ring
TRR7=Rimless Trim Ring
HB24=24" Bar Hangers

Note: Lamp not included.

Input Current (Max.)
120V
277V
.41A
.19A
.32A
.15A

Power Factor
120V
277V
>.62
>.66
>.49
>.50

120V
<11%
<12%

T.H.D.:
277V
<11%
<12%

DIMENSIONS

DESCRIPTION

Dimension “A”

FO17T8

27" (686mm)

FO25T8

39" (991mm)

FO32T8

51" (1295mm)

STL STAIRLITE
Stairwell Lighting
System

Architectural

Lamp

The StairLite System is
designed to satisfy all stairwell lighting requirements in
one easy to install package.
StairLite consists of a surface
mounted, two lamp fluorescent lighting fixture that
incorporates an integrally
mounted ultrasonic motion
detector, a system display
panel, and an optional full
battery backup. The StairLite
System will deliver vastly
reduced operating and maintenance costs due to virtually
no power consumption. It will
enhance the usefulness, safety, and reliability of any emergency lighting system. The
StairLite System is designed
for use in stairwells or any
other area of a building
where the occupancy level or
usage factor would be considered minimal.

EMERGENCY LIGHTS >

SURE-LITES®

EMERGENCY LIGHT

> Choice of Input Voltage,
120 or 277 VAC, 60Hz
> Formed 20 gauge steel
housing and cover plate
construction
> Durable white powder
coat finish
> T8 Fluorescent lamps in
17, 25 and 32 watts
(Lamps not included)
> Single-lamp electronic
ballast that is “0” Degree
rated

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: STL42F17

STL
Family
STL=StairLite

Operation
4=AC Only
54=Emergency
450 Lumens
57=Emergency
700 Lumens
59=Emergency
950 Lumens

Lamp
2F17=(2) FO17T8
(2' lamps)
2F25=(2) FO25T8
(3' lamps)
2F32=(2) FO32T8
(4' lamps)

Voltage
Blank=120 VAC
7=277 VAC

Accessories
(Order Separately)
VRSPD=#6 Spanner
Screw Driver

> Sealed, maintenance-free
nickel cadmium battery
> Fully automatic, self-test
ultrasonic motion detector
> Solid-state Status Indicator
Display System with an AC
power indicator
> Fully automatic emergency
charger is solid-state–no
mechanical relay
> Variety of electrical and
mounting knockouts for
a easy installation
> UL 924, Life Safety NFPA
101, NEC/OSHA, most
state and local codes

Energy Data

(2) 17W T8
(2) 25W T8
(2) 32W T8
Lamps Off

Input Power;
120V
277V
31W
31W
42W
42W
52W
52W
4.3W
4.3W

Input Current (Max.): Power Factor:
120V
277V
120V
277V
.29A
.13A
.8
.8
.36A
.16A
.8
.8
.44A
.19A
.9
.9
.04A
.02A
.7
.7

COOPER LIGHTING

19

Architectural

EMERGENCY LIGHTS >

SURE-LITES®
DIMENSIONS

DESCRIPTION

The StairLite System is
designed to satisfy all stairwell
lighting requirements in one
easy to install package. The
StairLite 2 is a surface mounted, two lamp fluorescent lighting fixture that incorporates an
integrally mounted ultrasonic
motion detector, a system display panel, and an optional full
battery backup.

STAIRLITE 2
Stairwell Lighting
System

EMERGENCY LIGHT

> Choice of Input Voltage,
120 or 277 VAC, 60Hz
> Formed 20 gauge steel
housing and cover plate
construction

The StairLite 2 includes bi-level
lamp operation so that one
lamp remains on constantly
while the motion detector
activates the second lamp
when needed to significantly
reduce the operate costs.
The StairLite System is
designed for use in stairwells
or any other area of a building
where the occupancy level or
usage factor would be considered minimal.

> Durable white powder
coat finish
> T8 32W Fluorescent lamps
(Lamps not included)
> Single-lamp electronic
ballast that is “0” Degree
rated
> Sealed, maintenance-free
nickel cadmium battery
> Fully automatic, self-test
ultrasonic motion detector
> Solid-state Status Indicator
Display System with an AC
power indicator
> Fully automatic emergency
charger is solid-state–no
mechanical relay
> Variety of electrical and
mounting knockouts for
a easy installation
> UL 924, Life Safety NFPA
101, NEC/OSHA, most
state and local codes

20

COOPER LIGHTING

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: STL24F032T87

STL2
Family
STL2=StairLite 2

Operation
4=AC Only
5=Self Powered

Lamp Type & Size
Blank=(2) 4’ Lamps
F032T8

Voltage
Blank=120 VAC
7=277 VAC

DESCRIPTION

DIMENSIONS

CC2

Commercial

The CC2 Contractor’s Choice
Emergency Lighting Unit is an
economic, yet attractive, alternative to standard two headed
emergency lighting units. All
components snap together to
facilitate installation in 2 minutes or less. Field adjustability
is not sacrificed for price, both
lighting heads have full horizontal and vertical adjustability. The Model CC2 Contractor’s
Choice is ideal for applications
which demand the minimum
product cost without sacrificing adjustability, dependability, or aesthetics.

EMERGENCY LIGHTS >

SURE-LITES®

C o n t r a c t o r ’s C h o i c e
EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz,
isolation transformer
> Injection-molded,
color- stable, high-impact
UL-94-5V rated polycarbonate housing
and mounting plate
(Housing is tethered to
mounting plate)

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of rated D.C. Voltage

Lamp Information

Model

DC Voltage 1 1/2 hours

Type

Wattage

Number

CC2
CC22146
CC2MRT
CC2SQ

6
6
6
6

Incandescent
Krypton
MR16
Incandescent

5.4
5.4
5.0
5.4

029121
029146
029139
029121

12
12
12
12

> Designer-white textured
finish
> Two PAR36 type lamps
in fully adjustable highimpact polycarbonate
lampholders

O R D E R I N G I N F O R M AT I O N

> Maintenance Free Sealed
Lead Calcium Battery

SAMPLE NUMBER: CC2

Model
Number
CC2
CC2347
(120/347VAC)

Options (Add as suffix)
MRT=MR16 Head (5W Standard)
SQ=Square Head (5.4W Standard)
V=Voltmeter
CSK120=Cord Set (120VAC)
BK=Black
Alternate Lamps 1
Other Options 1

Energy Data

Model No.
CC2
CC2347

1Consult

Accessories (Order separately)
1BRWH=Mounting Brackets (2) White
WG1=Wire Guard
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield
Weather Resistant

> Cutouts provided for
surface conduit on top
> Universal J-box mounting
pattern, keyhole slots
> Line-Latching, Solid-State
Voltage Limited Charger,
Solid-State Switching,
Low- Voltage Disconnect,
Brownout Circuit,
Overload/Short Circuit
Protection, Test
switch/power Indicator
light
> UL Damp Location Listed

Input Current (Max.):
120V
277V
347V
.12A
.05A
.12A
—
.01A

your Cooper Lighting Representative.

> UL 924 Listed, NOM
Certified, Life Safety NFPA
101, CSA Certified,
NEC/OSHA, most state
and local codes

COOPER LIGHTING

21

Commercial

EMERGENCY LIGHTS >

SURE-LITES®
DIMENSIONS

DESCRIPTION

CC3
CC4
CC5
CC6

The CC Series Contractor’s Choice
Emergency Lighting Unit is the ideal
choice when a simple installation and
a reasonable cost are required. Its
contemporary round corner styling,
designer white finish, and consistent
family appearance enables it to blend
with any decor. The components are
injection molded from tough polycarbonate materials which resist discoloration due to age and ultraviolet
radiation.

C o n t r a c t o r ’s C h o i c e
EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz,
isolation transformer

E L E C T R I C A L R AT I N G S

> Injection-molded,
color-stable, high-impact
UL-94-5V rated
polycarbonate housing
and mounting plate
(Housing is tethered to
mounting plate)

Model
CC3
CC3 NC
CC4
CC4 NC
CC5
CC5 NC
CC6

Rated Wattage to 87 1/2% of rated D.C. Voltage
DC Voltage 1 1/2 hours
6
10.8
6
16
6
18
6
18
6
27
6
24
6
32

2 hours
7.2
15

3 hours
10

4 hours
8

24

18

14

-

-

-

Lamp Information
Type
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent

Wattage
5.4
5.4
9
9
9
9
9

Number
29-121
29-121
29-84
29-84
29-84
29-84
29-84

> Designer-white textured
finish
> Two PAR36 type lamps in
fully adjustable high-impact
polycarbonate lampholders
> Sealed lead calcium
maintenance free battery
> Cutouts provided for
surface conduit on top
> Universal J-box mounting
pattern, keyhole slots
> Remote Capability
CC5, CC6

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER:

Model
Number
CC3
CC3NC(4)
CC4
CC4NC4, 6
CC5
CC5NC4, 6
CC6

CC5WHSD

Housing
Finish
(Must be
specified)
WH=White
BK=Black

Voltage
Blank=120/277
347=120/347 VAC

> Line-Latching, Solid-State
Voltage Limited Charger,
Solid-State Switching,
Low- Voltage Disconnect,
Brownout Circuit,
Overload/Short Circuit
Protection, Test
switch/power Indicator light
> UL Damp Location Listed
(CC5SD Only)
> UL 924 Listed, Life Safety
NFPA 101, CSA Certified,
NEC/OSHA, most state
and local codes

COOPER LIGHTING

Accessories (Order separately)
WG1 =Wire Guard
WG2 =Wire Guard (use for heads adjusted
at 45° or greater)
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield
Weather Resistant
CSK120=Cord Set 120V

Energy Data

Model No.
CC3
CC4
CC5
CC6

1Provision

22

Options
(add as suffix)
MRT=MR16 Heads (5W Standard
CC3, CC3NC; 9W Standard
CC4, CC5, and CC6)
SQ=Square Head (5.4W Standard)
A =Ammeter 1
SD=Self-Diagnostics3, 5, 6
V=Voltmeter1
TDM=Time Delay Monitor
Alternate Lamps2
Other Options 2

5CC5SD

Input Current (Max.):
120V
277V
347V
.12A
.05A
.01A
.12A
.05A
.01A
.13A
.06A
.06A
.13A
.06A
.06A

for one meter only. 2Consult your Cooper Lighting Representative. 3Not available w/CC6. 4NC=Nickel Cadmium Battery.
is damp location standard. 6CC4NC, CC5NC not available in SD.

DIMENSIONS

DESCRIPTION

13” [330mm]

4 7/8”
[124mm]
7 15/16” MAX
[202mm]

CC7
5 3/4”
[146mm]

Commercial

The CC7 Contractor’s Choice FasTest™
High Capacity Emergency Lighting
Units are an affordable, yet attractive,
alternative to standard white twoheaded emergency lighting units. All
components snap together to facilitate
installation in 5 minutes or less. Field
versatility is not sacrificed for cost,
both lighting heads offer full horizontal
and vertical adjustability. Moreover,
proper operation of the transfer circuit
and emergency lamps can be quickly
and safely verified by using a
convenient laser pointer (sold as an
accessory). In addition, Watchguard
EMS self diagnostic system is standard
(CC7NCSD only).

EMERGENCY LIGHTS >

SURE-LITES®

C o n t r a c t o r ’s C h o i c e
EMERGENCY LIGHT

19 1/4” MAX
[489mm]

The CC7 FasTest™ is ideal for
applications that demand the minimum
cost but also require maximum
flexibility, reliability and convenience in
an attractive unit.

> Dual-Voltage Input
120/277 VAC, 60 Hz
> Injection-Molded, ColorStable, High-Impact
UL 94-5V Rated
Polycarbonate Housing
and Mounting Plate
Verify proper operation of the
transfer circuit and emergency
lamps with a convenient laser
pointer (sold as an accessory).

> Designer white textured
finish
> Maintenance Free Sealed
Lead Calcium Battery or
Premium Nickel Cadmium
battery (CC7NCSD version
only)

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model

DC Voltage

1 1/2 Hours

Remote Wattage*

CC7

12

60

36

CC7NCSD

12

50

26

Lamp Information
Type

Wattage

Number

Incandescent
Incandescent

12W ea.
12W ea.

029-132
029-132

> Housing Has (8) Locations
for Mounting of Heads;
Consult Factory (3 optional
bottom-mount and 3
optional top- mount
locations)
> Knockouts/Cutouts
Provided in Housing
for Surface Conduit
Attachment

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: CC7208BMTDM

> Watchguard EMS self
diagnostic system
(CC7NCSD only)
Model Number
CC7
CC7NCSD

Options (Add as suffix)
SQ=Square Head (12W Standard)
MRT=MR16 Heads (12W Standard)
A=Ammeter
V=Voltmeter
SD=Self-Diagnostics (CC7NC Only)
TDM=Time Delay Monitor
Cord Set=CSK-120, CSK-277

SM=Side Mount Heads
TM=Top Mount Heads
BM=Bottom Mount Heads
Alternate Lamps, Head Types,
No Head, Multiple Heads1
Other Options1

Accessories (Order separately)
LASER=Key Chain, Red Laser Pointer
(activation tested at 50 feet)
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield
Weather Resistant
WG3=Wire Guard
2MS=Mounting Shelf (Specify Color)

Energy Data

Model No.
CC7
CC7
CC7NCSD

1Consult

Input Power
Input Current (Max.) Power Factor
120V
277V
120V
277V
120V
277V
Charge Mode (Fully Discharged Battery) Sealed Lead Calcium Battery
28W
28W
.26A
.11A
>.91
>.91
Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery
3.8W
3.7W
.07A
.03A
>.50
>.50
Standby Mode
7.8W
7.1W
.08A
.04A
>.77
>.77

your Cooper Lighting Representative.

T.H.D.
120V

277V

<35%

<39%

<94%

<99%

<53%

<58%

> Remote Photocell Test
Switch with Automatic
30-Sec. Test Upon Switch
Activation
> Line-Latching, Solid-State
Voltage Limited Charger,
Solid-State Switching,
Low-Voltage Disconnect,
Brownout Circuit,
Overload/Short Circuit
Protection, Push-Button
Test Switch/Power
Indicator Light
> UL 924, Life Safety NFPA
101, NEC/OSHA, Most
State and Local Codes

COOPER LIGHTING

23

Commercial

EMERGENCY LIGHTS >

SURE-LITES®
DESCRIPTION

CC8
C o n t r a c t o r ’s C h o i c e
High Capacity
EMERGENCY LIGHT

DIMENSIONS

The CC8 Contractor’s Choice
FasTest™ High Capacity Emergency
Lighting Units are an affordable, yet
attractive, alternative to standard
white two-headed emergency lighting
units. All components snap together
to facilitate installation in 5 minutes or
less. Field versatility is not sacrificed
for cost, both lighting heads offer
horizontal and vertical adjustability.
Moreover, proper operation of the
transfer circuit and emergency lamps
can be quickly and safely verified by
using a convenient laser pointer (sold
as an accessory).

15” [381mm]

3 15/16”
[100mm]
7 3/8” MAX
[187mm]

7 3/4”
[197mm]

The CC8 FasTest™ is ideal for
applications that demand the
minimum cost but also require
maximum flexibility, reliability and
convenience in an attractive unit.

22” MAX
[559mm]

> Dual-Voltage Input
120/277 VAC, 60 Hz
> Injection-Molded,
Color-Stable, High-Impact
UL 94-5V Rated
Polycarbonate Housing
and Mounting Plate

Verify proper operation of the
transfer circuit and emergency
lamps with a convenient laser
pointer (sold as an accessory).

> Designer white textured
finish
> Maintenance Free Sealed
Lead Calcium Battery

E L E C T R I C A L R AT I N G S

> Housing Has (8)
Locations for Mounting
of Heads; Consult Factory
(3 optional bottommount and 3 optional
top- mount locations)
> Knockouts/Cutouts
Provided in Housing
for Surface Conduit
Attachment
> Remote Photocell Test
Switch with Automatic
30-Sec. Test Upon
Switch Activation
> Line-Latching, Solid-State
Voltage Limited Charger,
Solid-State Switching,
Low-Voltage Disconnect,
Brownout Circuit,
Overload/Short Circuit
Protection, Push-Button
Test Switch/Power
Indicator Light

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model
CC8

DC Voltage

1 1/2 Hours

12

100

Remote Wattage*
76

Lamp Information
Type

Wattage

Number

Incandescent

12W ea.

029-132

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: CC8

CC8
Model Number
CC8

> UL 924, Life Safety NFPA
101, CSA Certified,
NEC/OSHA, Most State
and Local Codes

Options (Add as suffix)
SQ=Square Head (12W Standard)
MRT=MR16 Heads (12W Standard)
A=Ammeter
V=Voltmeter
TDM=Time Delay Monitor
Cord Set=CSK-120, CSK-277
SM=Side Mount Heads
TM=Top Mount Heads
BM=Bottom Mount Heads
Alternate Lamps, Head Types,
No Head, Multiple Heads1
Other Options1

Accessories (Order separately)
LASER=Key Chain, Red Laser Pointer
(activation tested at 50 feet)
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield
Weather Resistant
WG3=Wire Guard
2MS=Mounting Shelf (Specify Color)

Energy Data

Model No.
CC8
CC8

24

COOPER LIGHTING

1Consult

Input Power
Input Current (Max.) Power Factor
120V
277V
120V
277V
120V
277V
Charge Mode (Fully Discharged Battery) Sealed Lead Calcium Battery
28W
28W
.26A
.11A
>.91
>.91
Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery
4.1W
4.0W
.07A
.03A
>.50
>.50

your Cooper Lighting Representative.

T.H.D.
120V

277V

<35%

<39%

<94%

<99%

DIMENSIONS

DESCRIPTION

12”
[305mm]

21 11/16”
[551mm]

8 7/16”
[214mm]

9 7/8”
[250mm]

The CC Series Ultra High-Capacity
Emergency Lighting Units are ideal for
applications that demand the minimum
cost but also require maximum
flexibility, reliability and convenience in
an attractive unit.

CC9
CC10
CC11
CC12

Commercial

19”
[483mm]

The Contractor’s Choice FasTest™ Ultra
High-Capacity Emergency Lighting Units
are an affordable, yet attractive,
alternative to standard two-headed
emergency lighting units. All
components snap together to facilitate
installation in 5 minutes or less. Field
versatility is not sacrificed for cost, both
lighting heads offer horizontal and
vertical adjustability. Moreover, proper
operation of the transfer circuit and
emergency lamps can be quickly and
safely verified by using a convenient
laser pointer (sold as an accessory). In
addition, Watchguard EMS self
diagnostic system is standard.

EMERGENCY LIGHTS >

SURE-LITES®

C o n t r a c t o r ’s C h o i c e
Ultra High Capacity
EMERGENCY LIGHT

Self-Diagnostics

The self-diagnostic unit will
automatically perform the tests
required by the NFPA 101 Life
Safety Code. The system
indicates the status of the unit at
all times using an LED indicator
that is located near the test
switch.

Verify proper operation of the
transfer circuit and emergency
lamps with a convenient laser
pointer (sold as an accessory).

> Dual-Voltage Input
120/277 VAC, 60 Hz
> Injection-Molded,
Color-Stable, High-Impact
UL 94-5V Rated
Polycarbonate Housing
and Mounting Plate
> Designer white textured
finish
> Maintenance Free Sealed
Lead Calcium Battery

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model

DC Voltage

1 1/2 Hours

CC9SD
CC10SD
CC11SD
CC12SD
CC9SDMRT
CC10SDMRT
CC11SDMRT
CC12SDMRT

12
12
12
12
12
12
12
12

160
200
240
300
160
200
240
300

Lamp Information

Remote Capability
136W
176W
216W
276W
136W
176W
216W
276W

Type

Wattage

Number

Spacing1

Incandescent
Incandescent
Incandescent
Incandescent
MR16
MR16
MR16
MR16

12
12
12
12
12
12
12
12

029-132
029-132
029-132
029-132
029-141
029-141
029-141
029-141

24'
24'
24'
24'
50’
50’
50’
50’

ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.

> Housing Has (8) Locations
for Mounting of Heads;
Consult Factory (3 optional
bottom-mount and 3
optional top- mount locations)
> Knockouts/Cutouts
Provided in Housing for
Surface Conduit
Attachment
> Watchguard EMS self
diagnostic system

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: CC9SDMRT2142SM

> Remote Photocell Test
Switch with Automatic
30-Sec. Test Upon Switch
Activation
Model
Number
CC9SD
CC10SD
CC11SD
CC12SD

Options (Add as suffix)
SQ=Square Head (12W Standard)
MRT=MR16 Heads (12W Standard)
Alternate Lamps - Specify quantity,
lamp number (from Technical
Information section) and mounting
location (below), e.g.
CC9SD2134SM319TM219BM
SM=Side Mount Heads
(2 lamp max.)
TM=Top Mount Heads (3 lamp max.)
BM=Bottom Mount Heads
(3 lamp max.)

Electrical Options
A=Ammeter
V=Voltmeter
TDM- Time Daily Monitor
CSK120=120V Cord Set
CSK277= 277V Cord Set
Other Options: Consult Cooper
Lighting
Representative

Accessories (Order separately)
LASER=Key Chain, Red Laser Pointer
(activation tested at 30 feet)
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield
Weather Resistant
WG3=Wire Guard
2MSWH=Mounting Shelf

> Line-Latching, Solid-State
Voltage Limited Charger,
Solid-State Switching,
Low-Voltage Disconnect,
Brownout Circuit,
Overload/Short Circuit
Protection, Push-Button
Test Switch/Power
Indicator Light
> UL 924, Life Safety NFPA
101, NEC/OSHA, Most
State and Local Codes

1 The "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum

ratio. The corridor used is 100 feet long, 9 feet ceiling with a 6 feet wide walkway and 3 feet path of egress. The reflectances are 80% ceiling, 50% walls
and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees. Cooper Lighting assumes no responsibility for local
requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.

COOPER LIGHTING

25

Commercial

EMERGENCY LIGHTS >

SURE-LITES®
DIMENSIONS

DESCRIPTION

The Sure-Lites CU1 unit represents the next generation of emergency lighting. Sure-Lites has combined
dependable performance with a visually pleasing
design. The PRESTO™ unit is designed to harmonize
with today’s decor in commercial and public spaces.
Injection molded from high impact thermoplastic.

CU1
P R E STO ™ C o n te m p o ra r y
Unit

PRESTO™ is “contractor friendly.” The unique wiring
module makes installation a snap. All AC wiring connections are made with the polarized wiring module
and there is no need to juggle the unit in place.
PRESTO™ may be ceiling or wall mounted, horizontally or vertically, and may be installed to a standard
junction box or to surface mounted conduit.
Long life battery and solid-state engineering provide
trouble free operation. Two 5.4W wedge base incandescent lamps in locking specular reflectors appear to
float in clear acrylic domes for distortion free lighting.
Fully adjustable, locking lampheads with diffusing
lens cover.

EMERGENCY LIGHT

> Dual-Voltage Input
120/277 VAC, 60 Hz
Isolation Transformer
> Designer white textured
finish
> Maintenance Sealed
Lead Calcium Battery

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of rated D.C. Voltage
Model
CU1
CU1HD
CU1NC
CU1347
CU1HD347

Battery
SLC2
SLC2
SNC3
SLC2
SLC2

DC Voltage
6
6
6
6
6

1 1/2 hours
10.8
22
11
10.8
22

2 hours
7.2
16
7.2
7.2
16

3 hours
11
11

Lamp Information

Type
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent

> Suitable for Wall or Ceiling
Mount Applications.
O R D E R I N G I N F O R M AT I O N

> Universal J-Box Mounting
Pattern.
> Line-Latching, Solid-State
Voltage Limited Charger,
Solid-State Switching,
Low-Voltage Disconnect,
Brownout Circuit,
Overload/Short Circuit
Protection, Test Switch/
Power Indicator Light.

SAMPLE NUMBER: CU1PCL

Model
Number
CU1
CU1HD
CU1NC
CU1347
CU1HD347

> UL 924, Life Safety NFPA
101, CSA Certified,
NEC/OSHA ,Most State
and Local Codes.

Options (Add as suffix)
A=Ammeter
B=Black Finish
PCL=Polycarbonate Domes
SD=Self-Diagnostics
TDM=Time Delay Monitor
V=Voltmeter
Alternate Lamps1 (Wedge base & Krypton only)
Other Options1

Accessories (Order separately)
WG19 =Wire Guard
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield Weatherproof

Energy Data

Model No.
CU1, CU1HD
CU1NC
CU13474
CU1HD3474

26

COOPER LIGHTING

Input Current (Max.):
120V
277V
347V
.12A
.05A
.06A
.03A
.14A
.06A
.18A
.07A

1Consult your Cooper Lighting Representative. 2SLC=Sealed Lead Calcium 3SNC=Sealed Nickel Cadmium. 4347=347V for Canada.

Wattage
5.4
5.4
5.4
5.4
5.4

Number
29-121
29-121
29-121
29-121
29-121

DIMENSIONS

DESCRIPTION

The CU2 emergency light is an economic,
yet attractive, alternative to standard two
headed emergency lighting units. All
components snap together to facilitate
installation in 2 minutes or less.

11 1/8"
11 1/8”
[283mm]
[283mm]

3 3/16
[81mm]

The CU2 is ideal for applications which
demand the minimum product cost
without sacrificing dependability or
aesthetics.

Commercial

CU2

5 3/8”
[137mm]

EMERGENCY LIGHTS >

SURE-LITES®

Contemporary Unit
EMERGENCY LIGHT

> Dual-Voltage Input
120/277 VAC, 60 Hz
Isolation Transformer
> High Impact polycarbonate
Housing and Mounting
Plate with Designer-White
Textured finish
E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model
CU2
CU22146

DC Voltage
6
6

1 1/2 Hours
10.8
10.8

Type
Incandescent
Krypton

Wattage
5.4
5.4

SAMPLE NUMBER: CU2

CU2
Options (Add as suffix)
V=Voltmeter
CSK120=Cord Set (120 VAC)
Alternate Lamps1
Other Options1

Energy Data

Input Current (Max.):
120V=.12A
277V=.05A

Number
029-121
029-146

> Suitable for Wall or Ceiling
Mount Applications
(including floor proximity
installations)
> Universal J-Box Mounting
Pattern.

O R D E R I N G I N F O R M AT I O N

Model Number
CU2

> Maintenance Sealed
Lead Calcium Battery

Lamp Information

Accessories (Order separately)
CAX18PKWH=18" Pendant Kit, White
CAX18PKHTWH=18" Hang True Pendant Kit, White
1MSWH=Mounting Shelf, White
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield Weather Resistant
WG1=Wire Guard

> Line-Latching, Solid-State
Voltage Limited Charger,
Solid-State Switching,
Low-Voltage Disconnect,
Brownout Circuit,
Overload/Short Circuit
Protection, Test Switch/
Power Indicator Light.
> Damp Location Listed
Standard (CU-2 Only)
> UL 924, Life Safety NFPA
101, CSA Certified,
NEC/OSHA ,Most State
and Local Codes.
> ADA compliant

1Consult your Cooper Lighting Representative.

COOPER LIGHTING

27

Commercial

EMERGENCY LIGHTS >

SURE-LITES®
DESCRIPTION

DIMENSIONS

The XR Series is an efficient, rugged,
commercial grade emergency light.
The XR Series, in 6V and 12V models,
has the extra capacity to power remote
heads for added application flexibility.

XR SERIES
Steel
EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz
> 22 gauge die formed steel
housing
> White powder coat finish
> White, high impact,
thermoplastic
> (2) fully adjustable
thermoplastic heads - top
mounted (side mounting
optional)
> Knockout, conduit or cord
set
> Universal J-box mounting
pattern, keyhole slots
> Remote capability
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light
> UL 924 Listed, CSA
Certified, Life Safety NFPA
101, NEC/OSHA, most
state and local codes

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of rated D.C. Voltage
Model
Number

Lamp Information

Battery

DC Voltage

1 1/2 hours

2 hours

3 hours

4 hours

SLC
SLC
SLC
SLC
SLC
SLC
SLC
SLC
SLC
SLC
SLC
SNC
SNC
SNC
SNC
SNC

6
6
6
6
6
6
6
12
12
12
12
6
6
6
12
12

27
27
27
36
54
54
54
36
54
36
54
15
24
50
30
50

24
24
24
30
48
48
48
30
48
30
48
12
18
36
24
36

18
16
18
20
36
36
36
20
36
20
36
8
14
28
18
28

14
14
14
16
28
28
28
16
28
16
28
6
10
20
14
20

XR3
XR33471
XR5
XR7
XR9
XR11
XR113471
XR122063471
XR122083471
XR12206
XR12208
XR15
XR16
XR17
XR20
XR21

Type
Incandescent
Incandescent
Halogen Sealed Beam
Incandescent
Tungsten Halogen
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent

SLC=Sealed Lead Calcium Battery
SNC=Sealed Nickel Cadmium Battery

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: XR3TDM

Model
Number
XR3
XR3347
XR5
XR7
XR9
XR11
XR11347
XR12206
XR12206347
XR12208
XR12208347
XR15
XR16
XR17
XR20
XR21

Options (Add as suffix)
A=Ammeter
MH=Metal Heads
SD=Self-Diagnostics (XR3, XR5,
XR12206, XR12208, XR15,
XR16, XR20, XR21 Only)
TDM=Time Delay Monitor
V=Voltmeter
Alternate Lamps 2
Other Finishes 2
Other Options 2

Accessories (Order separately)
1BRWH =Mounting Brackets (2-White Finish)
1MSWH=Mounting Shelf (White Finish)
VK1 =Voltmeter
CSK120=Cord Set 120VAC
CSK277=Cord Set 277VAC
WG1=Wire Guard
VS2=Polycarbonate Vandal Shield
VS2WP=Polycarbonate Vandal Shield Weatherproof

Energy Data

Model No.
XR3, XR5, XR7, XR9, XR11
XR12206, XR12208
XR15
XR16
XR17
XR20
XR21

28

COOPER LIGHTING

Input Current (Max.):
120V
277V
.12A
.05A
.30A
.13A
.06A
.03A
.07A
.04A
.08A
.05A
.13A
.06A
.15A
.07A

Note: 0, 1, 3 & 4 Heads also available. Specify after catalog number [i.e., XR11484 = (XR11) with (4) 029-84 Lamps].
1347=120/347V 2Consult your Cooper Lighting Representative.

Wattage
9
9
6
9
6
9
9
9
9
9
9
7.2
7.2
7.2
9
9

29-84
29-84
29-37
29-84
29-12
29-84
29-84
29-86
29-86
29-86
29-86
29-88
29-88
29-88
29-86
29-86

DIMENSIONS

DESCRIPTION

A real workhorse in emergency lighting systems. These
durable, reliable units are
unparalleled in both performance and freedom from maintenance.

A
B
C
D
E
F
G
H

High Capacity

Ultra High Capacity

12 1/4” (311mm)
13 1/4” (337mm)
7 7/8” (200mm)
4 1/4” (108mm)
4 3/4” (121mm)
1 3/8” (35mm)
---------------------------------------------

17” (432mm)
16 7/8” (429mm)
11 1/2” (292mm)
8” (203mm)
6” (152mm)
2” (51mm)
5 3/4” (146mm)
2 1/2” (64mm)

HR SERIES

Commercial

The HR Series provide a low
cost, solid-state lighting system ideal for industrial, commercial or multi-housing environments. High capacity
makes the HR Series ideal for
installations where a large
number of heads/exits will be
remotely operated.

EMERGENCY LIGHTS >

SURE-LITES®

H i g h C a p a c i t y,
8 7 - 11 7 W a t t s
Ultra-High Capacity
17 0 - 3 6 0 Wa tt s
EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz
> 18 gauge die formed steel
housing and cover
> White powder coat finish

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of rated D.C. Voltage
Model

DC Voltage 1 1/2 hours
High Capacity
HR87*
6
87
HR117*
6
117
HR12117*
12
117
HR12117347*1
12
117
Ultra High Capacity
HR180*
6
HR12170*
12
HR12210*
12

180
170
210

2 hours

3 hours

65
87
87
87

43
58
58
58

135
128
157

90
85
105

4 hours
32
43
43
43

67
64
78

Lamp Information
Type

Wattage

Number

Incandescent
Incandescent
Incandescent
Incandescent

9
9
9
9

29-84
29-84
29-86
29-86

Incandescent 9
Incandescent 9
Incandescent 9

29-84
29-86
29-86

*Batteries may be shipped separately.

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: HR87TDM

Model
Number
HR87
HR117
HR12117
HR180
HR12170
HR12210
HR12360

Options (Add as suffix)
A=Ammeter
TDM=Time Delay Monitor
V=Voltmeter
Alternate Lamps 2
Other Options 2
Other finishes2
MH=Metal heads

Accessories (Order separately)
VK1 =Voltmeter
3BRWH =Mounting Brackets
2MSWH =Mounting Shelf (High Capacity)
3MSWH =Mounting Shelf (Ultra High Capacity)
WG3=Wire Guard (Ultra High Capacity)
WG7=Wire Guard (High Capacity)
CSK120=Cord Set (120VAC)
CSK277=Cord Set (277VAC)
VS2=Polycarbonate Vandal Shield
VS2WP=Polycarbonate Vandal Shield - Weatherproof

> Two top mounted, fully
adjustable, white, highImpact thermoplastic
heads
> Sealed lead-calcium
battery
> Knockout, conduit or cord
set
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test switch/
power indicator light
> UL 924 Listed, CSA
Certified, Life Safety NFPA
101, NEC/OSHA, most
state and local codes

Energy Data
Model No.
HR87
HR117
HR12117
HR12117347
HR180
HR12170
HR12210
HR12360

Input Current (Max.):
120V
277V
.50A
.21A
.53A
.22A
.26A
.13A
.25A
—
.98A
.43A
1.08A
.45A
1.02A
.47A
1.17A
.54A

347V

.60A

Note: 0, 1, 3 & 4 Heads also available. Specify after catalog number [i.e., HR12117379 = (HR12117) with (3) 29-79 Lamps].
1347=120/347V
2Consult your Cooper Lighting Representative.

COOPER LIGHTING

29

DESCRIPTION

DIMENSIONS

The HS1R emergency lighting
unit provides emergency
lighting when you need it
most. The fixture’s unique
design makes it adaptable to
many applications.

HS1R SERIES
Po rt a b l e
EMERGENCY LIGHT
with 6’ Cord & Plug

> Quick installation
(2 minutes)
> 120VAC 60Hz

6.0” [151mm]

5.0” [128mm]

The HS1R can be used as a
free standing unit or it can be
wall mounted using the
keyhole slots provided.
A 6-foot cord and plug are
provided for ease of AC power
hook-up. The integral handle
allows the HS1R to become
portable during power loss
when mobility is necessary.

6.5” [168mm]

7.0” [177mm]

Commercial

EMERGENCY LIGHTS >

SURE-LITES®

3.0” [75mm]

Two PAR20 style heads allow
total horizontal and vertical
aiming adjustability. The lamp
head selection switch allows
the choice for 1 lamp
illumination for 4 hours or
2-lamp illumination for 2
hours.

> Injection molded, color
stable, high impact
polycarbonate housing
> Designer white textured
finish

E L E C T R I C A L R AT I N G S

> Lamp Selection Switch for
1 or 2 lamp operation

Model

DC Voltage

HS1R

6

Rated Wattage to 87 1/2% of Rated D.C. Voltage
1 1/2 Hours
10.8

> Suitable for wall mount
applications
> Keyhole mounting slots
> Solid State Voltage Limited
Charger, Brownout Circuit,
Test Switch/Power
Indicator Light
> UL 924 Listed, Auxiliary
Equipment, CSA Certified,
NEC/OSHA, Meets most
State and Local Codes

30

COOPER LIGHTING

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: HS1R

HS1R
Model Number
HS1R

Accessories (order separately)
1BRWH=Mounting Brackets (2-White Finish)
1MSWH=Mounting Shelf (White Finish)

Lamp Information
Type
Incandescent

Wattage
5.4

Number
029-121

DIMENSIONS

DESCRIPTION

The LM Series is an emergency
light packaged in an attractive,
flame-resistant metal housing.
High-impact thermoplastic PAR36
heads permit unrestricted unit
placement and easy beam positioning.

LM1 SERIES

Commercial

The unit of choice for installations
where the size and cost of emergency lighting must be kept to a
minimum without sacrificing
dependability or light output.

EMERGENCY LIGHTS >

SURE-LITES®

Steel
EMERGENCY LIGHT
E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of rated D.C. Voltage

Lamp Information

Model

DC Voltage 1 1/2 hours

2 hours

Type

LM1

6

7.2

Incandescent 5.4

10.8

Wattage

Number

> Dual-voltage input
120/277VAC, 60Hz

029-121

> 18 gauge die formed
steel housing
> White powder coat finish

O R D E R I N G I N F O R M AT I O N

> Two PAR36 type lamps
in fully adjustable, white,
high-impact thermoplastic
lampholders

SAMPLE NUMBER: LM1V

LM1
Model
Number
LM1

Options (Add as suffix)
V=Voltmeter
Alternate Lamps1
Other Finishes1
Other Options1

Energy Data

Input Current
(Max.):
Model No.
LM1

1Consult

120V
.12A

277V
.05A

Accessories (Order separately)
1BRWH =Mounting Brackets (2) White
VK1=Voltmeter
CSK120=Cord Set 120VAC
CSK277=Cord Set 277VAC
WG2 =Wire Guard
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield Weatherproof

> Sealed lead calcium
battery
> Knockout, conduit or cord
set
> Universal J-box mounting
pattern, keyhole slots
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

your Cooper Lighting Representative.

COOPER LIGHTING

31

Commercial

EMERGENCY LIGHTS >

SURE-LITES®
DIMENSIONS

DESCRIPTION

A versatile “mini-system” featuring
reliability, quality metal construction,
optimum illumination and an attractive
compact appearance.
The popular choice for commercial,
institutional and public facilities where
moderate loads, economy, ease of
installation, safety and reliability are
important.

AA1 SERIES
Steel
EMERGENCY LIGHT

> Dual-voltage input
120/277VAC, 60Hz

E L E C T R I C A L R AT I N G S

> 22 gauge die formed
steel housing

Model

Battery

DC Voltage

1 1/2 hours

2 hours

3 hours

4 hours

Type

Wattage

Number

AA1
AA8

SLC3
SNC4

6
6

18
15

15
12

10
8

8
6

Incandescent
Incandescent

9
7.2

29-84
29-88

Rated Wattage to 87 1/2% of rated D.C. Voltage

Lamp Information

> White powder coat finish
> Two PAR36 type lamps in
fully adjustable, white,
high-impact thermoplastic
lampholders

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: AA1SD

> Sealed nickel cadmium
battery
> Knockout, conduit or cord
set

Model Number
AA1
AA8

> Universal J-box mounting
pattern, keyhole slots
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

Input Current

1Consult

COOPER LIGHTING

Accessories (Order separately)
1BRWH =Mounting Brackets (2) White
1MSWH=Mounting Shelf, White
VK1=Voltmeter
WG1 =Wire Guard
CSK120=Cord Set (120VAC)
CSK277=Cord Set (277VAC)
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield Weatherproof

Energy Data

(Max.):
Model No.
AA1
AA8

32

Options (Add as suffix)
A=Ammeter 2
SD=Self-Diagnostics
TDM=Time Delay Monitor
V=Voltmeter 2
Alternate Lamps 1
Other Finishes 1
Other Options 1

120V
.12A
.06A

277V
.05A
.03A

your Cooper Lighting Representative. 2Provision for one meter only. 3SLC=Sealed Lead Calcium 4SNC=Sealed Nickel Cadmium

DESCRIPTION

O R D E R I N G I N F O R M AT I O N
6 Volt Universal Remote Heads
Catalog No.
Lamp Type

Volts

Watts

Lamp No.

6T6XXU*
6T8XXU*
6T12XXU*
6X54XXU*
6X7XXU*
6X9XXU*
6X12XXU*
6X25XXU*

6
6
6
6
6
6
6
6

6
8
12
5.4
7
9
12
25

029-37
029-14
029-15
029-121
029-88
029-84
029-39
029-09

Halogen Sealed Beam
Halogen Sealed Beam
Halogen Sealed Beam
Incandescent Wedge Base
Incandescent Wedge Base
Incandescent Wedge Base
Incandescent Sealed Beam
Incandescent Sealed Beam

Catalog No.

Lamp Type

Volts

Watts

Lamp No.

12T8XXU*
12T12XXU*
12X9WHU*
12X12XXU*
12X25XXU*

Halogen Sealed Beam
Halogen Sealed Beam
Incandescent Wedge Base
Incandescent Sealed Beam
Incandescent Sealed Beam

12
12
12
12
12

8
12
9
12
25

029-16
029-79
029-86
029-26
029-08

Finish Codes: WH-White, BK-Black, GY-Grey.
Replace “XX” with desired Finish Code when ordering. (Example: 6T12WHU, for double head: 6T12DWH).
Alternate Lamps 1
*Remove “U”, Add “RD” suffix for Roundback Heads; Add “SQ” suffix for Square Heads - RD & SQ Heads
available in white only; SQ Head only available in wedge base and bi-pin lamps. (Example: GX7WHSQ)

Remote

12 Volt Universal Heads

Flame and impact resistant
injection molded thermoplastic PAR36 type lampholders.
Available in White, Grey and
Black finishes (specify color
when ordering.) Heads adjust
80° from vertical with 358°
rotation. Supplied complete
with thermoplastic lampholder
housings, swivel, lamp and 5"
diameter mounting plate.
Universal mounting plate has
three knockouts for mounting
lampholders on either side or
in center position. For double
head remotes, specify two
Universal Remote Head
Assemblies. UL 924 Listed,
CSA certified.

EMERGENCY LIGHTS >

SURE-LITES®

6V, 12V PLASTIC
REMOTES
Universal Remote Heads

SQ Heads Option

RD Heads Option

DESCRIPTION

O R D E R I N G I N F O R M AT I O N
6 Volt Single Head Weatherproof Remotes
Catalog No.
Lamp Type
6T6WXX
Halogen Sealed Beam
6T8WXX
Halogen Sealed Beam
6X7WXX
Incandescent Sealed Beam
6X9WXX
Incandescent Sealed Beam
6XW54WXX
Incandescent Wedge Base
6XW7WXX
Incandescent Wedge Base
6XW9WXX
Incandescent Wedge Base

Volts
6
6
6
6
6
6
6

Watts
6
8
7.2
8
5.4
7.2
9

Lamp No.
029-37
029-14
029-75
029-03
XW029-121
XW029-88
XW029-84

6 Volt Double Head Weatherproof Remotes
Catalog No.
Lamp Type
6T6DWXX
Halogen Sealed Beam
6T8DWXX
Halogen Sealed Beam
6X7DWXX
Incandescent Sealed Beam
6X9DWXX
Incandescent Sealed Beam
6XW54DWXX
Incandescent Wedge Base
6XW7DWXX
Incandescent Wedge Base
6XW9DWXX
Incandescent Wedge Base

Volts
6
6
6
6
6
6
6

Watts
6
8
7.2
8
5.4
7.2
9

Lamp No.
029-37
029-14
029-75
029-03
XW029-121
XW029-88
XW029-84

12 Volt Single Head Weatherproof Remotes
Catalog No.
Lamp Type
12T8WXX
Halogen Sealed Beam
12T12WXX
Halogen Sealed Beam
12X25WXX
Incandescent Sealed Beam
12XW9WXX
Incandescent Wedge Base
12XW12WXX
Incandescent Wedge Base

Volts
12
12
12
12
12

Watts
8
12
25
9
12

Lamp No.
029-16
029-79
029-08
XW029-86
XW029-132

12 Volt Double Head Weatherproof Remotes
Catalog No.
Lamp Type
12T8DWXX
Halogen Sealed Beam
12T12DWXX
Halogen Sealed Beam
12X25DWXX
Incandescent Sealed Beam
12XW9DWXX
Incandescent Wedge Base
12XW12DWXX
Incandescent Wedge Base

Volts
12
12
12
12
12

Watts
8
12
25
9
12

Lamp No.
029-16
029-79
029-08
XW029-86
XW029-132

Finish Codes: WH-White, GY-Grey , BK-Black.
Replace “XX” with desired Finish Code when ordering. (Example: 6T6DWWH).

Designed to perform in wet
locations. Flame and impact
resistant injection molded
thermoplastic PAR36 lampholders. Die cast, aluminum
gasketed mounting plate.
Sealed swivel and coated
lamp terminals resist oil, water
and dust. Available in standard
industrial white, grey and
black finishes (specify color
when ordering). Heads adjust
80° from vertical with 358°
rotation. Supplied complete
with thermoplastic lampholder
housings, swivel, lamp and 5"
diameter die cast, grey mounting plate. UL 924 Listed, CSA
Certified. UL Wet Location
Listed.

6V, 12V PLASTIC
WEATHERPROOF
REMOTES
Single and Double
Remote Heads

Alternate Lamps 1
1Consult

your Cooper Lighting Representative.

COOPER LIGHTING

33

DESCRIPTION

EMERGENCY LIGHTS >

Remote

SURE-LITES®
Lamp housing is made of corrosion resistant 22 gauge die formed
spun aluminum with a powder
coat finish. Die cast aluminum
swivel assembly allows 80° adjustment from vertical with 358° rotation. Stainless steel mounting
plate mounts flush on wall or ceiling and is designed for installation
on standard electrical box. (Single
head remotes are supplied with
single gang plate, double head
remotes are supplied with three
gang plate). UL 924 Listed, CSA
Certified.

6V, 12V METAL
HEAD REMOTES

Catalog No.

Lamp Housing +
Mounting Plate
Finish

Lamp Type

Volts

Watts Lamp No.

Halogen Sealed Beam
Halogen Sealed Beam
Incandescent Sealed
Beam

6
6
6

6
12
7.2

029-37
029-15
029-75

6 Volt Double Metal Head Remotes
6T6DMHWH
White
6T12DMHWH
White

Halogen Sealed Beam
Halogen Sealed Beam

6
6

6
12

029-37
029-15

12 Volt Single Metal Head Remotes
12T12MHWH
White
12T50MHWH
White

Halogen Sealed Beam
Halogen Sealed Beam

12
12

12
50

029-79
029-135

12 Volt Double Metal Head Remotes
12T12DMHWH
White
12T50DMHWH
White

Halogen Sealed Beam
Halogen Sealed Beam

12
12

12
50

029-79
029-135

6 Volt Single Metal Head Remotes
6T6MHWH
White
6T12MHWH
White
6X7MHWH
White

Alternate Lamps 1
Other Finishes 1

Single and Double
Remote Heads
DESCRIPTION

6V, 12V
WEATHERPROOF
METAL HEAD
REMOTES

O R D E R I N G I N F O R M AT I O N

O R D E R I N G I N F O R M AT I O N

6 Volt Single Metal Weatherproof
Designed to perform in wet
Catalog
Heads
Lamp Type
locations. Lamp housing is
One
Incandescent - Sealed Beam
made of corrosion resistant 22 6X7WMHWH
6X8WMHWH
One
Incandescent - Sealed Beam
gauge die formed spun alu6X12WMHWH
One
Incandescent - Sealed Beam
minum with a powder coat fin- 6X18WMHWH
One
Incandescent - Sealed Beam
ish and a die cast aluminum,
6X25WMHWH*
One
Incandescent - Sealed Beam
6T6WMHWH
One
Halogen - Sealed Beam
gasketed mounting plate.
6T8WMHWH
One
Halogen - Sealed Beam
Sealed swivel and coated
6T10WMHWH
One
Halogen - Sealed Beam
lamp terminals resist oil, water 6T12WMHWH*
One
Halogen - Sealed Beam
and dust. Available in standard 6T20WMHWH*
One
Halogen - Sealed Beam
industrial white finish-specify
6XW54WMHWH
One
Wedge Base - Incandescent
One
Wedge Base - Incandescent
color when ordering; other fin- 6XW7WMHWH
6XW9WMHWH
One
Wedge Base - Incandescent
ishes available. Heads adjust
80° from vertical with 358°
12 Volt Single Metal Weatherproof
Catalog
Heads
Lamp Type
rotation. Supplied complete
12X12WMHWH
One
Incandescent - Sealed Beam
with a 5" diameter die cast,
One
Incandescent - Sealed Beam
grey finished, gasketed mount- 12X18WMHWH
12X25WMHWH*
One
Incandescent - Sealed Beam
ing plate. UL 924 Listed, CSA
12X30WMHWH*
One
Incandescent - Sealed Beam
Certified. City of Chicago Code 12T8WMHWH
One
Halogen - Sealed Beam
(see catalog numbers with*),
12T12WMHWH*
One
Halogen - Sealed Beam
12T37WMHWH*
One
Halogen - Sealed Beam
UL Wet Location Listed.
12T50WMHWH*
12XW9WMHWH
12XW12WMHWH

One
One
One

Halogen - Sealed Beam
Wedge Base - Incandescent
Wedge Base - Incandescent

Volts
6
6
6
6
6
6
6
6
6
6
6
6
6

Watts
7
8
12
18
25
6
8
10
12
20
5.4
7.2
9

Lamp Number
029-75
029-03
029-39
029-13
029-09
029-37
029-14
029-36
029-15
029-18
029121
02988
02984

Volts
12
12
12
12
12
12
12
12
12
12

Watts
12
18
25
30
8
12
37.5
50
9
12

Lamp Number
029-26
029-19
029-08
029-126
029-16
029-79
029-134
029-135
02986
029132

Volts
6
6
6
6
6
6
6
6
6
6
6
6
6

Watts
7
8
12
18
25
6
8
10
12
20
5.4
7.2
9

Lamp Number
029-75
029-03
029-39
029-19
029-09
029-37
029-14
029-36
029-15
029-18
029121
02988
02984

Volts
12
12
12
12
12
12
12
12
12
12

Watts
12
18
25
30
8
12
37.5
50
9
12

Lamp Number
029-26
029-19
029-08
029-126
029-16
029-79
029-134
029-135
02986
029132

6 Volt Double Metal Weatherproof
Catalog
6X7DWMHWH
6X8DWMHWH
6X12DWMHWH
6X18DWMHWH
6X25DWMHWH*
6T6DWMHWH
6T8DWMHWH
6T10DWMHWH
6T12DWMHWH*
6T20DWMHWH*
6XW54DWMHWH
6XW7DWMHWH
6XW9DWMHWH

Single and Double
Remote Heads

Heads
Two
Two
Two
Two
Two
Two
Two
Two
Two
Two
Two
Two
Two

Lamp Type
Incandescent - Sealed Beam
Incandescent - Sealed Beam
Incandescent - Sealed Beam
Incandescent - Sealed Beam
Incandescent - Sealed Beam
Halogen - Sealed Beam
Halogen - Sealed Beam
Halogen - Sealed Beam
Halogen - Sealed Beam
Halogen - Sealed Beam
Wedge Base - Incandescent
Wedge Base - Incandescent
Wedge Base - Incandescent

12 Volt Double Metal Weatherproof
Catalog Notes:
WH – White (standard finish),
GY – Grey,
BK – Black
* Meets City of Chicago Code

1Consult

34

COOPER LIGHTING

your Cooper Lighting
Representative.

Catalog
12X12DWMHWH
12X18DWMHWH
12X25DWMHWH*
12X30DWMHWH*
12T8DWMHWH
12T12DWMHWH*
12T37DWMHWH*
12T50DWMHWH*
12XW9DWMHWH
12XW12DWMHWH

Heads
Two
Two
Two
Two
Two
Two
Two
Two
Two
Two

Lamp Type
Incandescent - Sealed Beam
Incandescent - Sealed Beam
Incandescent - Sealed Beam
Incandescent - Sealed Beam
Halogen - Sealed Beam
Halogen - Sealed Beam
Halogen - Sealed Beam
Halogen - Sealed Beam
Wedge Base - Incandescent
Wedge Base - Incandescent

DESCRIPTION

O R D E R I N G I N F O R M AT I O N

6 Vo l t S i n g l e H e a d M R 1 6 R e m o t e H e a d s
Catalog No.

Lamp Type

Volts

Watts

Lamp No.

MRT6T5

MR16

6

5

029-139

MRT6T9

MR16

6

9

029-143

MRT6T12

MR16

6

12

029-140

6 Vo l t D o u b l e H e a d M R 1 6 R e m o t e H e a d s
Lamp Type

Volts

Watts

Lamp No.

MRT6T5D

MR16

6

5

029-139

MRT6T9D

MR16

6

9

029-143

MRT6T12D

MR16

6

12

029-140

1 2 Vo l t S i n g l e H e a d M R 1 6 R e m o t e H e a d s
Catalog No.

Lamp Type

Volts

Watts

Lamp No.

MRT12T12

MR16

12

12

029-141

MRT12T20

MR16

12

20

029-142

MRT12T50

MR16

12

50

029-144

Remote

Catalog No.

The MR16 Remote includes a
steel gimbal ring and arm with
a glass lens and an injection
molded thermoplastic canopy.
Available in White only. Heads
adjust 80° from vertical with
358° rotation. Supplied complete with gimbal ring assembly, MR16 lamping, glass lens,
and 5” diameter mounting
plate. MR16 gimbal ring assemblies come pre-mounted to
canopy in single and double
head configurations. Use WG8
Wire Guard for single head
remotes; and WG9 Wire Guard
for double head remotes. UL
Listed, Life Safety NFPA 101.

EMERGENCY LIGHTS >

SURE-LITES®

MR16 SERIES
Single and Double
Remote Heads

1 2 Vo l t D o u b l e H e a d M R 1 6 R e m o t e H e a d s
Catalog No.

Lamp Type

Volts

Watts

Lamp No.

MRT12T12D

MR16

12

12

029-141

MRT12T20D

MR16

12

20

029-142

MRT12T50D

MR16

12

50

029-144

DESCRIPTION

The Metrolite MR Series are 6V or 12V DC remotes that provide continuity in style when used with the
ML Series. The MR Series sculptured and compact appearance makes it perfect for high quality interior
applications. The self-contained, feature rich design packs a powerful punch with its super-bright halogen lamp and precision optics. The integral mounting plate makes installation fast and easy. UL listed.
O R D E R I N G I N F O R M AT I O N
Single Head Remotes
Catalog No.
Lamp Type
MR6T12
Bi-Pin Halogen
MR12T12
Bi-Pin Halogen

DC Voltage
6
12

Watts
12
12

Lamp No.
029-66
029-45

Double Head Remotes
Catalog No.
Lamp Type
MR6T12D
Bi-Pin Halogen
MR12T12D
Bi-Pin Halogen

DC Voltage
6
12

Watts
12
12

Lamp No.
029-66
029-45

Alternate Lamps 1

MR SERIES
Single and Double
Remote Heads

1Consult

your Cooper Lighting Representative.

COOPER LIGHTING

35

Remote

EMERGENCY LIGHTS >

SURE-LITES®
O R D E R I N G I N F O R M AT I O N

DESCRIPTION

Single Head Remotes
Catalog No.
CFR103
CFR116

CFR
Matches SLC Series emergency
lighting units. Lamp heads
adjust 80° from vertical with
358° rotation. Die-formed steel
faceplate has a white, corrosion-resistant finish. Cabinet
has side knockout for conduit
connection as well as universal
pattern mounting knockouts.
UL listed.

Lamp Type
Incandescent Sealed Beam
Halogen Sealed Beam

Volts
6
12

Watts
8
8

Lamp No.
029-03
029-16

Lamp Type
Incandescent Sealed Beam
Halogen Sealed Beam

Volts
6
12

Watts
8
8

Lamp No.
029-03
029-16

Double Head Remotes
Catalog No.
CFR203
CFR216
Alternate Lamps 1

CFR SERIES
CYLINDER REMOTES
Single and Double
Head Remotes

DESCRIPTION

DR SERIES

DR
Matches RD Series emergency
lighting units. Heads are injection molded high gloss thermoplastic. Lamp heads adjust
80° from vertical with 358°
rotation. Single head remotes
supplied with single gang
mounting plate, double head
remotes supplied with three
gang mounting plate.
UL listed.

O R D E R I N G I N F O R M AT I O N
Single Head Remotes
Catalog No.
Finish
DR112
White
DR166
White
DR145
White

Lamp Type
Halogen Bi-Pin T2 1/4
Halogen Bi-Pin T2 1/4
Halogen Bi-Pin T2 1/4

Volts
6
6
12

Watts
6
12
12

Lamp No.
029-12
029-66
029-45

Lamp Type
Halogen Bi-Pin T2 1/4
Halogen Bi-Pin T2 1/4
Halogen Bi-Pin T2 1/4

Volts
6
6
12

Watts
6
12
12

Lamp
029-12
029-66
029-45

Volts
6
6

Watts
5.4
5.4

Lamp No.
029-121
029-121

Volts
6
12

Watts
8
8

Lamp No.
029-03
029-16

Double Head Remotes
Catalog No.
DR212
DR266
DR245

Finish
White
White
White

Alternate Lamps 1

DESIGNER REMOTES
Single and Double
Head Remotes

CU1 SERIES
SPECIALTY REMOTES

DESCRIPTION

O R D E R I N G I N F O R M AT I O N

CU1R
Matches CU1 Series
Emergency lighting units. For
use with CU1HD emergency
lighting unit or 6V DC Class 2
circuit. Clear acrylic dome (for
polycarbonate dome, add PCL
suffix to catalog number).
UL listed

CU1R Series
Catalog No.
CU1R
CU1RB

DESCRIPTION

O R D E R I N G I N F O R M AT I O N

GFR
Matches RG1 Series emergency lighting units. 20 gauge
die-stamped steel housing
with white baked-enamel finish. Available with 6 volt or 12
volt incandescent sealed beam
lamps. UL 924 damp location
listed.

GFR Series
Catalog No.
GFR2703
GFR2716

Finish
White
Black

Lamp Type
Incandescent Wedge Base
Incandescent Wedge Base

Alternate Lamps 1
Other Finishes 1

Single Head Remotes

GFR SERIES
SPECIALTY REMOTES

Alternate Lamps 1
Other Finishes 1

Single Head Remotes

36

1Consult

COOPER LIGHTING

your Cooper Lighting Representative.

Finish
White Trim
White Trim

Lamp Type
Incandescent Sealed Beam
Halogen Sealed Beam

DESCRIPTION

R4C
Matches P4C Series emergency lighting units. Impact resistant thermoplastic housing is UL924 rated.
Black thermoplastic body with white plastic collar and reflector. For semi-recessed installation, order
USF1 accessory. For fully recessed installation, order FRK1 accessory.
O R D E R I N G I N F O R M AT I O N
R4C Series
Catalog No.
R4C140
R4C145

Lamp Type
Halogen Bi-Pin T2 1/4
Halogen Bi-Pin T2 1/4

Volts
6
12

Watts
10
12

Lamp No.
029-40
029-45

R4C SERIES
Emergency Remotes

Remote

Alternate Lamps 1
Other Finishes 1

EMERGENCY LIGHTS >

SURE-LITES®

DESCRIPTION

RFR
20 gauge die-stamped steel housing with white baked enamel finish. 5 1/2" housing accommodates
2x6 joist construction. Available with 6 volt or 12 volt incandescent double contact bayonet base
lamps. UL Damp Location Listed.
O R D E R I N G I N F O R M AT I O N
RFR Series
Catalog No.
RFR130
RFR153

Finish
White Trim
White Trim

Lamp Type
Incandescent DC Bayonet Base
Incandescent DC Bayonet Base

Volts
6
12

Watts
6.6
7.5

Lamp No.
029-30
029-53

RFR SERIES

Alternate Lamps 1
Other Finishes 1

Emergency Remotes

DESCRIPTION

ULTIMATE REMOTE HEAD
The Sure-Lites Ultimate Series explosion-proof, emergency lighting fixtures are designed for remote mounting in
Class I, Division II Group A, B, C, and D locations such as oil refineries, oil and gasoline loading docks, chemical and
petrochemical plants, paint manufacturing sites, pumping stations and other process industry facilities where similar
hazards threaten. UL 844 listed. UL 924 wet location listed.
O R D E R I N G I N F O R M AT I O N - C L A S S I , D I V I S I O N I I , G R O U P S A , B , C , D ( U L 8 4 4 H A Z A R D O U S L I ST E D )
Catalog Number

Lamp Type

Volts

Watts

Lamp No.

T-Code

Lamp Data

MRT6T5HAZ
MRT6T9HAZ
MRT6T12HAZ
MRT12T12HAZ
MRT12T20HAZ

MR16
MR16
MR16
MR16
MR16

6
6
6
12
12

5
9
12
12
20

029-139
029-143
029-140
029-141
029-142

T3A
T2C
T2A
T2A
T1

ADX031520
ADX031520
ADX031520
ADX031520
ADX031520

O R D E R I N G I N F O R M AT I O N - W E T L O C AT I O N ( U L 9 2 4 W E T LO C AT I O N L I ST E D )

ULTIMATE
REMOTE SERIES

Emergency Remotes

Catalog Number

Lamp Type

Volts

Watts

Lamp No.

Lamp Data

MRT6T5W
MRT6T9W
MRT6T12W
MRT12T12W
MRT12T20W
MRT12T50W

MR16
MR16
MR16
MR16
MR16
MR16

6
6
6
12
12
12

5
9
12
12
20
50

029-139
029-143
029-140
029-141
029-142
029-144

ADX031520
ADX031520
ADX031520
ADX031520
ADX031520
ADX031520

DESCRIPTION

HZB/HZP
The Sure-Lites HZP Series and HZB Series explosion-proof, emergency lighting fixtures are designed for remote
mounting in Class I, Division 1, Group C, D and Class II, Division 1, Group E, F, G locations such as oil refineries, oil
and gasoline loading docks, chemical and petrochemical plants, paint manufacturing sites, pumping stations and
other process industry facilities where similar hazards exist. Body and globe guard are copper-free, corrosion resistant light weight aluminum, with a heat and impact resistant glass globe. UL 924 Listed, Life Safety NFPA 101, NEC
Class I, division 1, Groups C, D and Class II, Division 1, Groups E, F, G, NEC/OSHA, most state and local codes. UL
Damp Location Listed.

HZB/HZP SERIES

O R D E R I N G I N F O R M AT I O N
HZ Series
Catalog No.
12X25HZP
12X25HZB

1Consult

Mounting
Pendant
Bracket

Lamp Type
Incandescent
Incandescent

Volts
12
12

Watts
25
25

Lamp No.
ZZ-13
ZZ-13

Emergency Remotes

your Cooper Lighting Representative.

COOPER LIGHTING

37

DESCRIPTION

EXIT SIGNS >

Architectural

SURE-LITES®

ELX SERIES

DIMENSIONS

The Sure-Lites ELX Series
Recessed Exits are designed
for architectural excellence
and minimal presence. The
crystal clear wedge shaped
panel allows architectural
details to shine through while
providing excellent light
distribution and exit visibility.
Long life, energy-efficient LED
lamps reduce energy costs
and eliminate routine lamp
maintenance.

Edge-Lit
AC Only
Recessed
EXIT LIGHTING

> Dual Voltage Input
120/277 VAC or 120/347
VAC 60 Hz
> 20 gauge recessed steel
housing with nine conduit
knockouts
> Recessed housing may be
ordered separately2
> Injection molded highimpact acrylic panel
> LED or Fluorescent
Lamping
> Fluorescent: Two F8T5
lamps wired for separate
circuits

*Fluorescent Only (LED=3 3/4”)

O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : E L X 4 10 0 R M A R E

ELX
Factory Options
Blank=None
95=AC Only Fire
Alarm Interface
(LED ONLY)

Family
ELX=Edgelit
Exit Series
Series
4=AC Only,
Fluorescent
6=LED Lamps, AC Only
Face Options
1=Single Face
2=Double Face
Battery
00=No Battery

> Mirror and white inserts
provided standard with all
exits

Letter Color1
R=Red
G=Green

Mounting Options
C=Ceiling
W=Wall
E=End
Options
2C=Two Circuit Option-FTBR (LED
Only)

Accessories (Order Separately)
277V Conversion Kit
CAN277ELX=277V Transformers,
Mounting Hardware
(fluorescent only)

C H E V R O N C O N F I G U R AT I O N

> Damp Location Listed
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes
UL FTBR Listed - Standard
Fluorescent, LED with 2C
Option

Voltage
Blank=120V (fluorescent
only)
7=277V (fluorescent only)
Blank=Dual-voltage
120/277V (LED Only)
47=120/347V (LED Only)

Chevron Direction
Blank=No Chevron
AR=Right Chevron
AL=Left Chevron
DA=Double Chevron
ARL=Chevrons Right/Left
(Double Face Only)

> Universal Background
(Field selectable: clear,
mirror or white)

> Molded letters and
chevrons improve
aesthetic appearance
and increase visibility

Trim Finish
Blank=Brushed
Aluminum
WH=White
BL=Black
BZ=Bronze
BS=Brass
CR=Chrome

FRONT

BACK

FACE

AR . . . . . . . . . . . . . . . . . . . EXIT>
AL . . . . . . . . . . . . . . . . . . . 
DA . . . . . . . . . . . . . . . . . . 
ARL . . . . . . . . . . . . . . . . . EXIT>

Blank
Blank
Blank

.56

>.30 —

>10% >11% —

>.34
>.73

>.19 >.15
>.34 >.28

<35% <19% <17%
<50% <30% <26%

your Cooper Lighting Representative.

DIMENSIONS

DESCRIPTION

Architectural

The Sure-Lites ELX Series
Recessed Exits are designed
for architectural excellence and
minimal presence. The crystal
clear wedge shaped panel
allows architectural details to
shine through while providing
excellent light distribution
and exit visibility.Long life,
energy-efficient LED lamps
reduce energy costs and eliminate routine lamp maintenance.

EXIT SIGNS >

SURE-LITES®

ELX SERIES
Edge-Lit
S e l f - Powe re d

*Fluorescent Only (LED=3 3/4”)

Recessed
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N

> Dual-voltage input 120/277
VAC or 120/347 VAC 60Hz

SAMPLE NUMBER: ELX5170RARE

ELX
Factory Options
(LED EXITS ONLY)
Blank=None
90=DC Only Fire
Alarm Interface

Family
ELX=Edgelit
Exit Series
Series
5=Self-Powered,
Fluorescent
7=Self-Powered,
LED Lamps

Trim Finish
Blank=Brushed
Aluminum
WH=White
BL=Black
BZ=Bronze
BS=Brass
CR=Chrome

Face Options
1=Single Face
2=Double Face
Battery
70=Nickel Cadmium

Letter Color1
R=Red
G=Green
Chevron Direction
Blank=No Chevron
AR=Right Chevron
AL=Left Chevron
DA=Double Chevron
ARL=Chevrons Right/
Left (Double Face
Only)

> 20 gauge steel recessed
housing with nine conduit
knockouts

Voltage
Blank=120/277V
Dual-voltage
47=120/347V
(LED Exits Only)

> Recessed housing may be
ordered separately2
> Injection molded highimpact acrylic panel

Mounting Options
C=Ceiling
W=Wall
E=End

> LED or Fluorescent
lamping

SD=Self-Diagnostics
(LED EXITS ONLY)

> Fluorescent: two F8T5
lamps wired for separate
circuits

Accessories (Order Separately)
(LED EXITS ONLY)
Laser=Key Chain, Red Laser
Pointer (activation tested at 30 feet.

> Premium Nickel Cadmium
battery
> Watchguard EMS
Self-Diagnostic System
(Standard)
> Universal Background
(Field selectable: clear,
mirror or white)
> Mirror and white inserts
provided standard with all
exits

C H E V R O N C O N F I G U R AT I O N
FRONT

BACK

FACE

AR . . . . . . . . . . . . . . . . . . . EXIT>
AL . . . . . . . . . . . . . . . . . . . 
DA . . . . . . . . . . . . . . . . . . 
ARL . . . . . . . . . . . . . . . . . EXIT>

Blank
Blank
Blank

 Molded letters and
chevrons improve
aesthetic appearance
and increase visibility

Energy Data

Input Power:
120V 277V 347V

Input Current (Max.):
Power Factor:
120V 277V 347V
120V 277V 347V
Fluorescent Exits
Fluorescent Exits -8W Lamps 14W 14W
.21A .09A
>.56 >.58
LED Exits with Self-Diagnostics Option
LED Exits -Red Letters
4.9W 4.8W .05A .02A
>.90 >.87
LED Exits - Green Letters
4.9W 4.7W .05A .02A
>.85 >.82
-

1Mirror

insert installed standard. White insert shipped in carton.

2Consult

your Cooper Lighting Representative.

T.H.D.:
120V 277V 347V
<12% <12%

-

<25% <24%
<25% <24%

-

> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test switch/
power indicator light.
> Damp Location Listed
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

COOPER LIGHTING

39

DESCRIPTION

DIMENSIONS

The Sure-Lites ES Series
Exits are designed for
architectural excellence and
minimal presence. The
crystal clear wedge shaped
panel allows architectural
details to shine through
while providing excellent
light distribution and exit
visibility. Long life, energyefficient LED lamps reduce
energy costs and eliminate
routine lamp maintenance.

EXIT SIGNS >

Architectural

SURE-LITES®
CEILING MOUNT RECESSED

C E I L I N G M O U N T S U R FA C E

WA L L M O U N T R E C E S S E D

WA L L M O U N T S U R FA C E

ES SERIES
O R D E R I N G I N F O R M AT I O N - C O M P L E T E U N I T S R E C E S S E D / S U R FA C E
S A M P L E N U M B E R : E S 7 17 0 W H R DAC

Edge-Lit
AC Only
S e l f - Powe re d
R e c e s s e d a n d S u r fa c e

EXIT LIGHTING

> Dual-voltage Input,
120/277 VAC 60Hz
> 18 gauge steel housing
with conduit knockouts
> Extruded trim plate in
Brushed or Polished
Aluminum, Polished Brass,
White, Black and Bronze
> Injection molded highimpact acrylic panel
> Clear, mirror, or white
background
> LED Lamping: Super-bright,
long life LEDs provide
uniform illumination
> Sealed nickel cadmium,
maintenance free, long life
battery (Self Powered only)
> Full Recharge Time,
24 hrs. (max.)
> Recessed housing available
for ceiling or wall mounting
> Convenient 1/2" knockouts
provided in top and end of
surface mounted housing
> Self-powered Exits feature
solid-state voltage charger,
solid-state switching,
brownout circuit, test
switch/power indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

ES
Mounting
Blank=Recessed
S=Surface Unit

Family
ES=Edgelit
Exit Series
Series
6=LED Lamps,
AC Only
7=LED Lamps,
Self-Powered
Face Options
1=Single Face
2=Double Face

COOPER LIGHTING

Letter/
Background Color
R=Red/Clear
(Single Face Only)
RM=Red/Mirror
RW=Red/White
G=Green/Clear
(Single Face Only)
GM=Green/Mirror

Battery
Blank=AC Unit
70=Nickel Cadmium
(Self-powered Only)

Chevron
Direction
Blank=No
Chevrons
AL=Chevron
Left
AR=Chevron
Right
DA=Double
Chevrons
ARL=Chevron
Right/Left
(Double
Face Only)

Mounting
Options
C=Ceiling
E=End (Surface Only)
W=Wall
P=Pendant (Surface Only)

Voltage
Blank=Dual-voltage,
120/277V

O R D E R I N G I N F O R M AT I O N - R E C E S S E D H O U S I N G
SAMPLE NUMBER: ESH71

Family
ESH=Housing
(Recessed Only)

Series
6= AC Only
7=Self-Powered

Face Options
1=Single Face (Self-powered Only)
2=Double Face (Self-powered Only)

O R D E R I N G I N F O R M AT I O N - R E C E S S E D T R I M
S A M P L E N U M B E R : E ST 7 1 W H R DAC

Family
EST=Trim and Panel
(Recessed Only)

Series
6=LED Lamps, AC Only
7=LED Lamps, Self-Powered
Face Options
1=Single Face
2=Double Face

Trim Finish
Blank=Brushed
Aluminum
BL=Black
PS=Polished
Brass
BZ=Bronze
PA=Polished
Aluminum
WH=White

Letter/
Background Color
R=Red/Clear
(Single Face Only)
RM=Red/Mirror
RW=Red/White
G=Green
GM=Green/Mirror
GW=Green/White

Voltage
Chevron
Blank=Dual
Direction
Voltage,
Blank=No
120/277V
Chevrons
AL=Chevron
Left
AR=Chevron
Right
DA=Double
Chevrons
ARL=Chevron Right/Left
(Double Face Only)

Mounting
Options
C=Ceiling
W=Wall

Energy Data
Input Power:

LED Exits, Red Letters, AC Only
LED Exits, Red Letters, Self-Powered
LED Exits, Green Letters, AC Only
LED Exits, Green Letters, Self-Powered

40

Trim Finish
Blank=Brushed
Aluminum
BL=Black
PS=Polished
Brass
BZ=Bronze
PA=Polished
Aluminum
WH=White

Input Current (Max.):

Power Factor:

120V

277V

120V
LED Exits

277V

120V

277V

120V

T.H.D.:
277V

6.7W
7.0W
1.6W
2.0W

6.7W
7.0W
1.6W
2.1W

.06
.06
.02
.02

.03
.03
.01
.01

.8
.8
.6
.7

.8
.8
.6
.7

20%
20%
55%
45%

20%
20%
82%
68%

DESCRIPTION

DIMENSIONS

Architectural

The CX Surface Mounted Die
Cast Aluminum Exit combines
the strength and durability of
die casting with the bright
even illumination of LED lamp
sources. Unlike competitive
units that have a pronounced
dot effect from protruding
diodes, the CX LED offers
unequalled uniform
illumination and brightness.
The CX Self-Powered LED
comes standard with the
Watchguard EMS
self-diagnostic system insuring
fixture reliability and reducing
maintenance costs.

EXIT SIGNS >

SURE-LITES®

CX SERIES
Die Cast
AC Only
S e l f - Powe re d
EXIT LIGHTING

Self-Diagnostics

> Dual-voltage Input
120/277 VAC, 60 Hz,
isolation transformer

The self-diagnostic unit will automatically perform
the tests required by the NFPA 101 Life Safety Code.
The system indicates the status of the unit at all
times using an LED indicator that is located near the
test switch.

> Die cast aluminum
housing
> Die cast canopy included
> LED Lamping
> Watchguard EMS
Self-Diagnostic System
(CX7 Only)

O R D E R I N G I N F O R M AT I O N

> Exit can be universally
mounted: ceiling, wall
or end

SAMPLE NUMBER: CX7170RSD

CX
Family
CX=Die Cast
Aluminum
Exit
Series
6=AC Only, LED
7=Self-Powered,
LED

Battery
Letter Colors
Blank=No
R=Red
Battery (CX6) G=Green
70=Nickel
Cadmium
Battery (CX7)

Face Options
1=Single
2=Double

SD=SelfHousing
Diagnostic
Finishes
*(CX7 only)
Blank=
Brushed
Aluminum
Face with
Black
Housing
W=White
B=Black

Options
2C=Two Circuit
Operation,
FTBR
(CX6 Only)

Accessories (Order Separately)
CAX18PKBK=18" Pendant Kit,
Black
CAX18PKWH=18" Pendant Kit,
White
CAX18PKHTBK=18” Hang-True
Pendant Kit, Black
CAX18PKHTWH=18” Hang-True
Pendant Kit, White
VS1=Polycarbonate Vandal Shield
(Wall Mount Only)
VS1WP=Weather Resistant
Polycarbonate Vandal
Shield (Wall Mount Only)
WG10=Wire Guard (Wall Mount
Only)
WGS11=Wire Guard (Ceiling or
End Mount Only)

> Universal pattern knockouts on rear of single
face housing for direct
mounting to junction box
> NFPA 101 compliant
knockout chevrons allow
quick conversion to
directional signs
> Self-powered Exits feature
line-latching, solid-state
voltage limited charger,
low-voltage disconnect,
brownout circuit,
over-load/short-circuit
protection, test switch/
power indicator light

E n e rgy Da t a — S e l f - Powe re d E x i t s

Sealed Nickel Cadmium Battery
Input Power:
Input Current (Max.):

LED Exits -Red Letters
LED Exits -Green Letters

120V

277V

2.8W
3.9W

2.9W
3.6W

120V 277V
LED Exits
.03A
.08A

.02A
.04A

Power Factor:

T.H.D.:

120V

277V

120V

277V

> .81
> .41

> .77
> .43

< 32% < 46%
< 48% < 49%

Energy Data — AC Only Exits

Input Power:

LED Exits -Red Letters
LED Exits -Green Letters

120V

277V

2.4W
3.2W

2.5W
3.0W

Input Current (Max.):
120V 277V
LED Exits
.03A
.08A

.02A
.03A

Power Factor:

T.H.D.:

120V

277V

120V

> .78
> .33

> .73
> .35

< 33% < 48%
< 50% < 52%

277V

> Damp Location Listed
(AC Only)
> UL 924 Listed, CSA
Certified, Life Safety NFPA
101, NEC/OSHA, Energy
Star Listed, AC Only-UL
FTBR when specified with
the “2C” option, most
state and local codes, suitable for floor proximity
installation.

COOPER LIGHTING

41

DESCRIPTION

DIMENSIONS

The Sure-Lites Pinnacle Family
of Surface Mounted Die Cast
Aluminum Exits combine
strength, durability and
aesthetics. The architecturally
compatible finishes will add a
new dimension to any design.

EXIT SIGNS >

Architectural

SURE-LITES®

CAX SERIES
Die Cast
AC Only
LED Lamping
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N - L E D L A M P E X I T S
S A M P L E N U M B E R : C A X 6 10 0 6 5 R B

> 120 VAC or 277 VAC Input
wattage
> Die cast aluminum
housing with hinged
face plate and die cast
canopy for ceiling or end
mounting
> Universal: ceiling, wall, or
end mounting
> Screw-In LED Lamps:
two 1W long life T6 1/2
intermediate base lamps
> Universal pattern knockouts
on rear of single face
housing for direct
mounting to junction box
> NFPA 101 compliant
knockout chevrons allow
quick conversion to
directional signs
> Damp Location Listed
(except exits with “2C”
Option)
> UL 924 Listed, Life Safety
NFPA 101, CSA certified,
NEC/OSHA, UL FTBR Listed
(consult your Cooper
Lighting Representative for
applicable fixture types),
most state and local codes

CAX
Family
CAX=Die Cast
Aluminum Exit
Surface Mount

Factory
Options
00=No Options
65=Tamperproof Screws
85=Vandal Shield

Series
6=AC Only,LED

Letter Colors
R=Red
G=Green

Face Options
1=Single
2=Double

Housing
Finishes
Blank=Brushed
Aluminum
Face with
Black
Housing
W=White
B=Black
BZ=Bronze
Voltage
Blank=120/277V
47=120/347V

Battery
00=No Battery

Factory Options
2C= Two Circuit Operation

Accessories (Order Separately)
Screwdrivers
059012SP=Tamperproof Screwdriver Bit
VRSD=Vandal Resistant Screwdriver
WG10=Surface, Mount Wire Guard
WGS11=Ceiling, End Mount Wire Guard
VS1=polycarbonate vandal shield
Pendant Kits
CAX18PK=Pendant Kit, white
CAX18PKHT=”Hang-true” Pendant Kit,
white

O R D E R I N G I N F O R M AT I O N - S C R E W - I N L E D E X I T S
S A M P L E N U M B E R : C A X 1 L E DAC R

CAX
Family
CAX=Die Cast
Aluminum Exit
Surface Mount
Face Options
1=Single
2=Double

Factory
Options
65=Tamperproof
Screws
85=Vandal Shield
95=AC Only Fire
Alarm Interface
Lamp Type
LED=LED Lite Stix™
Screw-in LED
Lamps

Emergency Operation
AC=AC Only
Letter Color
R=Red
Housing Finishes
Blank=Brushed Aluminum
Face with Black Housing
W=White
B=Black
BZ=Bronze
Voltage
Blank=120V
77=277V

Accessories (Order Separately)
DC Socket Kit
PDC6=Two 6V, 3.6W DC lamps
PDC12=Two 12V, 3.6W DC lamps
Emergency Power Pack
CAX3PP=Black
CAX3PPW=White
CAX3PPBZ=Bronze
277V Conversion Kit
AD277CAX=Black
AD277CAXW=White
AD277CAXBZ=Bronze
Vandal Resistant Screwdrivers
059012SP=Tamperproof
Screwdriver Bit
VRSD=Vandal Resistant Screwdriver
WG10=Surface, Mount Wire Guard
WGS11=Ceiling, End Mount Wire Guard
VS1=Polycarbonate Vandal Shield

Energy Data

Red Letters Single Face
Red Letters Double Face
Green Letters Single Face
Green Letters Double Face
Red Letters

42

COOPER LIGHTING

Input Power:
Input Current(Max.):
120V 277V 347V
120V 277V 347V
Standard Power - LED Exits
5.6W 5.7W 6.0W
.07A .03A .02A
7.3W 7.5W 8.3W
.07A .03A .03A
6.7W 6.8W 6.8W
.07A .03A .02A
9.5W 9.7W 9.9W
.09A .04A .03A
LED Lite-Stix™ Screw-In Lamps
2.0W 4.3W
.09A .03A

Power Factor:
120V 277V

T.H.D.:
120V 277V

>.71
>.83
>.79
>.90

>.71
>.83
>.79
>.90

<36%
<33%
<30%
<26%

<36%
<34%
<31%
<27%

>.19

>.58

<19%

<22%

DIMENSIONS

DESCRIPTION

Architectural

The Sure-Lites Pinnacle
Family of Surface Mounted
Die cast Aluminum Exits
combine a strength, durability
and aesthetics. The
architecturally compatible
finishes will add a new
dimension to any design.

EXIT SIGNS >

SURE-LITES®

CAX SERIES
Die Cast
AC Only
Incandescent, Compact
Fluorescent Lamping
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N - I N C A N D E S C E N T, F L U O R E S C E N T L A M P E X I T S
S A M P L E N U M B E R : C A X 4 10 0 6 5 R B

CAX
Family
CAX=Die Cast
Aluminum Exit

Series
2=AC Only, Incandescent
4=AC Only, Fluorescent

Face Options
1=Single
2=Double
Battery
00=No Battery

Factory
Options
00=No Options
65=Tamperproof Screws
85=Vandal Shield
95=AC Only Fire Alarm2
Interface
Letter Colors
R=Red
G=Green
RWO=Red on White1
GWO=Green on White1
WRO=White on Red1
WGO=White on Green1
O=Open Face1

Housing
Finishes
Blank=Brushed
Aluminum
Face with
Black
Housing
W=White
B=Black
BZ=Bronze

> 120 VAC or 277 VAC
input voltage

Factory Options
2C= Two Circuit Operation

Accessories (Order Separately)
DC Socket Kit (Incandescent only)
PDC6=Two 6V, 3.6W DC lamps
PDC12=Two 12V, 3.6W DC lamps

> Universal: ceiling, wall, or
end mounting

Emergency Power Pack
(Incandescent Only)
CAX3PP=Black
CAX3PPW=White
CAX3PPBZ=Bronze

Voltage
Blank=120V
77=277V

> Die cast aluminum
housing with hinged face
plate and die-cast canopy
for ceiling or end
mounting

> AC incandescent: two 20W
T6 1/2 intermediate base
lamps

277V Conversion Kit
AD277CAX=Black
AD277CAXW=White
AD277CAXBZ=Bronze

> AC fluorescent: two 5W
F5TT compact fluorescent
lamps

Screwdrivers
0590-12SP=Tamperproof Screwdriver Bit
VRSD=Vandal Resistant Screwdriver
Wire Guard
WG1=Surface, Wire Guard
WGS11=Ceiling, End Wire Guard
VS1=Polycarbonate Vandal Shield
Pendant Kits
CAX18PK=Pendant Kit, white
CAX18PKHT=”Hang-true” Pendant Kit, white

> Universal pattern
knockouts on rear of
single face housing for
direct mounting to
junction box
> NFPA 101 compliant
knockout chevrons allow
quick conversion to
directional signs
> Stencil and open face
signs available
> Downlight diffuser

Energy Data

Input Power:
120V
277V
Incandescent Exits

4.0W

4.2W

Fluorescent Exits - 5W Lamps
Fluorescent Exits - 7W Lamps

14W
15W

21W
23W

Input Current (Max.):
120V
277V
Incandescent Exits
.33A
.16A
Fluorescent Exits
.29A
.32A
.25A
.30A

> Damp Location Listed

Power Factor:
120V
277V

T.H.D.:
120V

277V

-

-

-

-

>.40
>.50

>.24
>.27

<14%
<16%

<11%
<12%

> UL 924 Listed, Life Safety
NFPA 101, CSA certified,
NEC/OSHA, UL FTBR
Listed (consult your
Cooper Lighting
Representative for
applicable fixture types),
most state and local codes

Notes: AC compact fluorescent CAX Series Exits cannot be converted to self-powered emergency.
1RWO, GWO, WRO, and WGO are open face styles with “EXIT” legend. Use “O” option for ordering special wording-lenses ordered
separately (consult Cooper Lighting Representative). 2AC Only Fire Alarm Interface Option available on incandescent lamp exits only.

COOPER LIGHTING

43

DESCRIPTION

DIMENSIONS

The Sure-Lites Pinnacle Family
of Surface Mounted Die cast
Aluminum Exits combine
strength, durability and
aesthetics. The architecturally
compatible finishes will add a
new dimension to any design.

EXIT SIGNS >

Architectural

SURE-LITES®

CAX SERIES
O R D E R I N G I N F O R M AT I O N - L E D L A M P E X I T S

Die Cast
S e l f - Powe re d
LED Lamping
EXIT LIGHTING

> Dual-voltage input
120/277VAC, 60Hz
> Die cast Aluminum
housing with hinged
faceplate and die cast
canopy for ceiling or
end mounting
> Universal: ceiling, wall, or
end mounting
> Screw-in LED lamps: two
1W long life T 6 1/2
intermediate base lamps
> Lead Calcium or Premium
Nickel Cadmium battery
> Universal pattern
knockouts on rear of
single face housing for
direct mounting to
junction box

SAMPLE NUMBER: CAX717020R

CAX
Family
CAX=Die Cast Aluminum
Exit Surface Mount

Factory Options
00=No Options
20=DC Flasher
30=DC Flasher/ Buzzer
65=Tamperproof Screws
85=Vandal Shield
90=DC Only Fire Alarm
Interface

Series
7=Self-Powered LED

Face Options
1=Single
2=Double

> UL 924 Listed, Life Safety
NFPA 101, CSA certified,
NEC/OSHA, most state
and local codes

44

COOPER LIGHTING

Factory Options
SD=Self Diagnostics

Letter Colors
R=Red
G=Green

Battery
70=Nickel Cadmium

Accessories (Order Separately)
Screwdrivers
0590-12SP=Tamperproof
Screwdriver Bit
VRSD=Vandal Resistant
Screwdriver
VS1=polycarbonate vandal shield
Pendant Kits
CAX18PK=Pendant Kit, white
CAX18PKHT=”Hang-true”
Pendant Kit, white
WG10=Surface
WGS11=Ceiling, end

O R D E R I N G I N F O R M AT I O N - S C R E W - I N L E D L A M P S
SAMPLE NUMBER: CAX1LEDSPR

Family
CAX=Die Cast Aluminum
Exit Surface Mount
Face Options
1=Single
2=Double
Battery
Blank=Lead Calcium
70=Nickel Cadmium

Factory Options
Blank=None
20=DC Flasher
30=DC Flasher/ Buzzer
65=Tamperproof Screws
85=Vandal Shield
90=DC Fire Alarm Interface

Lamp Type
LED=LED Lite Stix™
Screw-in LED Lamps

> NFPA 101 compliant
knockout chevrons allow
quick conversion to
directional signs
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test switch/
power indicator light

Housing Finishes
Blank=Brushed Aluminum
Face with Black Housing
W=White
B=Black
BZ=Bronze

Emergency Operation
SP=Self-Powered

Factory Options
SD= Self-Diagnostics

Letter Color
R=Red
Housing Finishes
Blank=Brushed Aluminum
Face with Black Housing
W=White
B=Black
BZ=Bronze
Voltage
Blank=120V/277V
47=120/347V

Accessories (Order Separately)
059012SP=Tamperproof
Screwdriver Bit
VRSD=Vandal Resistant
Screwdriver
VS1=polycarbonate vandal
shield
Pendant Kits
CAX18PK=Pendant Kit, white
CAX18PKHT=”Hang-true”
Pendant Kit, white
WG10=Surface
WGS11=Ceiling, end

Wa tt a g e R a t i n g s
Lead Calcium Battery=10.8W for 1 1/2 hrs., 7.2W for 2 hrs.

Nickel Cadmium Battery=15.0W for 1 1/2 hrs.

Energy Data
Standard Power - Sealed Nickel Cadmium Battery - LED Exits
Input Power:
Input Current (Max.):
Power Factor:
T.H.D.:
120V
277V
347V
120V
277V
347V
120V
277V
120V
277V
Red Letters Single Face
7.4W
7.5W
7.6W
.08A
.04A
.03A
>.72
>.72
<34%
<34%
Red Letters Double Face
9.3W
9.5W
9.6W
.09A
.04A
.03A
>.84
>.84
<31%
<32%
Green Letters Single Face
8.5W
8.7W
8.4W
.09A
.04A
.03A
>.79
>.79
<30%
<31%
Green Letters Double Face
11.4W 11.7W
11.2W
.11A
.05A
.04A
>.90
>.90
<26%
<26%
Standard Power with Self Diagnostics Option (Fully Discharged Battery) - LED Exits
Red Letters Single Face
8.4W
8.5W
8.6W
.08A
.04A
.03A
>.82
>.82
<31%
<31%
Red Letters Double Face
9.8W
9.5W
9.7W
.09A
.04A
.03A
>.86
>.84
<30%
<30%
Green Letters Single Face
9.1W
9.0W
9.2W
.09A
.04A
.03A
>.86
>.85
<27%
<27%
Green Letters Double Face
11.2W 10.5W
10.5W
.10A
.05A
.03A
>.90
>.88
<25%
<26%
Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by approximately 1.5 Watts
Self Diagnostic Option with Low Power Option (Operating in Low Power Mode) (Fully Discharged Battery) - LED Exits
Red Letters Single Face
6.5W
6.7W
.07A
.03A
>.75
>.72
<37%
<37%
Red Letters Double Face
7.8W
8.1W
.08A
.04A
>.80
>.80
<33%
<33%
Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by approximately 4 Watts
Charge Mode, Fully Discharged Battery): Sealed Lead Calcium Battery Screw-in LED Lamps
Red Letters 16.6W
17.5W
.15A
.07A
>.90
>.91
<28%
<28%
Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by approximately 10 Watts in
the standby operating mode
Sealed Nickel Cadmium Battery: Screw-in LED Lamps
Red Letters 8.4W
8.3W
.08A
.03A
>.92
>.92
<35%
<34%

DESCRIPTION

DIMENSIONS

Architectural

The Sure-Lites Pinnacle Family
of Surface Mounted Die Cast
Aluminum Exits combine
strength, durability and aesthetics. The architecturally
compatible finishes will add a
new dimension to any design.

EXIT SIGNS >

SURE-LITES®

CAX SERIES
Die Cast
S e l f - Powe re d

O R D E R I N G I N F O R M AT I O N - I N C A N D E S C E N T, F L U O R E S C E N T E X I T S
S A M P L E N U M B E R : C A X 3 10 0 8 5 R

Incandescent, Compact
Fluorescent Lamping

CAX
Family
CAX=Die Cast Aluminum
Exit Surface Mount

Factory Options
00=No Options
20=DC Flasher1
30=DC Flasher/ Buzzer1
65=Tamperproof Screws
85=Vandal Shield
90=DC Only Fire Alarm
Interface1

Series
3=Self-Powered, Incandescent
5=Self-Powered, Fluorescent
Face Options
1=Single
2=Double

Housing Finishes
Blank=Brushed Aluminum
Face with Black Housing
W=White
B=Black
BZ=Bronze
Voltage
Blank=120V/277V

Accessories (Order Separately)
Screwdrivers
059012SP=Tamperproof
Screwdriver Bit
VRSD=Vandal Resistant
Screwdriver
Wire Guard
WG1=Surface, Wire Guard
WGS11=Ceiling, End Wire
Guard

Letter Colors
R=Red
G=Green
RWO=Red on White2
GWO=Green on White2
WRO=White on Red2
WGO=White on Green2
O=Open Face2

Battery
00=Lead Calcium
70=Nickel Cadmium

Factory Options
SD=Self-Diagnostic
(Incandescent Only)

VS1=Polycarbonate Vandal
Shield
Pendant Kits
CAX18PK=Pendant Kit, white
CAX18PKHT=”Hang-true”
Pendant Kit, white

EXIT LIGHTING

> Dual-voltage input
120/277VAC, 60Hz
> Die cast aluminum
housing with hinged
faceplate and die-cast
canopy for ceiling or end
mounting
> Universal: ceiling, wall, or
end mounting
> AC incandescent: two 20W
T6 1/2 intermediate base
lamps
> AC fluorescent: two 5W
F5TT compact fluorescent
lamps
> Lead Calcium or Premium
Nickel Cadmium battery

Wa tt a g e R a t i n g s
Lead Calcium Battery=10.8W for 1 1/2 hrs., 7.2W for 2 hrs.

Nickel Cadmium Battery=15.0W for 1 1/2 hrs.

> Universal pattern
knockouts on rear of
single face housing for
direct mounting to
junction box

Energy Data

Charge Mode (Fully Discharged Battery): Sealed Lead Calcium Battery
Input Power:
Input Current (Max.):
Power Factor:
120V
277V
120V
277V
120V 277V
Incandescent Exits-20W Lamps 53W
Fluorescent Exits-5W Lamps
29W

51W
30W

.45A
.40A

.19A
.16A

>.99
>.61

>.98
>.66

T.H.D.:
120V
277V
<9%
<12%

<10%
<11%

Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 12 Watts in the
standby operating mode
Sealed Nickel Cadmium Battery
Incandescent Exits-20W Lamps 45W
43W
.38A
.16A
>.99 >.99
<7%
<7%
Fluorescent Exits - 5W Lamps 20W
21W
.36A
.15A
>.48 >.52
<15%
<14%

> NFPA 101 compliant
knockout chevrons allow
quick conversion to
directional signs
> Stencil and open face
signs available
> Downlight diffuser
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light
> UL 924 Listed, Life Safety
NFPA 101, CSA Certified,
NEC/OSHA, UL FTBR
Listed, most state and
local codes

1DC

Flasher, DC Flasher/Buzzer and DC Fire Alarm Interface options available with Incandescent exits only. 2RWO, GWO, WRO, and WGO
are open face styles with “Exit” legend. Use “O” option for ordering special wording-lenses ordered separately (consult Cooper Lighting
Representative).

COOPER LIGHTING

45

DIMENSIONS

DESCRIPTION

EXIT SIGNS >

Architectural

SURE-LITES®

TPX SERIES
Die Cast
AC Only

R E M OT E
POWERED

A C O N LY

The TPX Thin Profile Exit
Series combines the strength
of die cast aluminum, the profile of recessed design
and the superior aesthetics of
LED technology. The TPX
Series faceplate assembly is
only 3/4" thick, yielding a sign
with minimal off-wall protrusion without requiring the
large wall opening of a fully
recessed exit.
The TPX Series also includes
a Remote Powered Exit which
can be powered from a TPX
Series AC Only or SelfPowered Exit.

Thin Profile
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N - A C O N LY E X I T S

> Dual-voltage input
120/277VAC, 60Hz
> Die cast aluminum faceplate
> Overall exposed exit thickness is only 3/4"
> LED lamping

S A M P L E N U M B E R : T P X 6 10 0 0 0 R B

TPX
Family
TPX=Thin Profile
Exit
Series
6=AC Only, LED

> 20 gauge steel recessed
housing fits in 2x4 construction

Face Options
1=Single

> 18 gauge steel mounting
plate with universal
mounting pattern

Battery
00=AC Only, 120/277 VAC

> Adjustable hanger bars
> Centerpin Torx tamper
resistant screws on sides
of faceplate – no visible
mounting hardware on
front face
> NFPA compliant knockout
chevrons
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA, UL
FTBR Listed (with “2C”
option), UL Listed as suitable for floor proximity
installation, most state and
local codes

Factory
Options
00=No Options
95=AC Only Fire
Alarm Interface
Letter Colors
R=Red
G=Green

Faceplate Finishes
Blank=Brushed
Aluminum Face
with Black Trim
W=White
B=Black
BZ=Bronze

Accessories (Order Separately)
TPX61VS=Polycarbonate Vandal
Shield
0590A639SP=Tamper Resistant
Screwdriver Bit

Factory
Options
2C= Two Circuit
Operation

O R D E R I N G I N F O R M AT I O N - R E M O T E P O W E R E D E X I T S (Satellite, must be powered from another unit.)
S A M P L E N U M B E R : T P X 8 10 0 0 0 R

Family
TPX=Thin Profile
Exit

Factory
Options
00=No Options

Series
8=Remote, LED

Letter Colors
R=Red
G=Green

Face Options
1=Single

Battery
00=Remote Powered

Faceplate
Finishes
Blank=Brushed
Aluminum Face
with Black Trim
W=White
B=Black
BZ=Bronze
Accessories (Order Separately)
TPX61VS= Polycarbonate
Vandal Shield
0590A639SP= Tamper Resistant
Screwdriver Bit

Energy Data

Red Letters Single Face
5.6W
Red Letters Single Face with Remote
Green Letters Single Face 6.7W
Green Letters Single Face with Remote

Red Letters Single Face
Green Letters Single Face

46

COOPER LIGHTING

Standard Power - LED Exits
Input Power:
Input Current (Max.):
120V
277V
120V
277V
5.7W
.07A
.03A
>.71
7.3W
7.3W
.07A
.03A
6.8W
.07A
.03A
>.79
9.5W
9.7W
.09A
.04A
Remote Powered - LED Exits
Approximately 2.0 watts additional
Approximately 2.5 watts additional

Power Factor:
120V 277V
>.71
<36%
>.83
>.83
>.79
<30%
>.90
>.90

T.H.D.:
120V 277V
<36%
<33% <34%
<31%
<26% <27%

DIMENSIONS

DESCRIPTION

The TPX Series also includes
a Remote Powered Exit which can
be powered from a TPX Series AC
Only or Self-Powered Exit.

Architectural

The TPX Thin Profile Exit Series
combines the strength of die cast
aluminum, the profile of recessed
design and the superior aesthetics
of LED technology. The TPX Series
faceplate assembly is only 3/4"
thick, yielding a sign with minimal
off-wall protrusion without requiring the large wall opening of a fully
recessed exit.

EXIT SIGNS >

SURE-LITES®

TPX SERIES
Die Cast
S e l f - Powe re d
Thin Profile
EXIT LIGHTING

> Dual-voltage input
120/277VAC, 60Hz

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: TPX717020RB

> Die cast aluminum
faceplate

TPX
Family
TPX=Thin Profile
Exit

Factory
Options
00=No Options
20=Flasher
30=Flasher/Buzzer
90=DC Fire Alarm
Interface

Series
7=Self-Powered

Face Options
1=Single

Letter Colors
R=Red
G=Green

Faceplate
Finishes
Blank=Brushed
Aluminum Face
with Black Trim
W=White
B=Black
BZ=Bronze

Accessories (Order Separately)
TPX71VS=Polycarbonate Vandal
Shield
0590A639SP=Tamper Resistant
Screwdriver Bit

> LED Lamping
> Premium Nickel Cadmium
battery
> 20 gauge steel recessed
housing fits in 2x4
construction

Factory
Options
SD= Self-Diagnostics

Battery
70=Nickel Cadmium Battery

> Overall exposed exit
thickness is only 3/4"

> 18 gauge steel mounting
plate with universal
mounting pattern
> Adjustable hanger bars

Energy Data

Standard Power - Sealed Nickel Cadmium Battery - LED Exits

Red Letters Single Face
Red Letters Single Face with Remote
Green Letters Single Face
Green Letters Single Face with Remote

Input Power;
120V
277V
7.4W
7.5W
9.3W
9.5W
8.5W
8.7W
11.4W
11.7W

Input Current (Max.):
120V
277V
.08A
.04A
.09A
.04A
.09A
.04A
.11A
.05A

Power
120V
>.72
>.84
>.79
>.90

Factor:
277V
>.72
>.84
>.79
>.90

T.H.D.:
120V 277V
<34% <34%
<31% <32%
<30% <31%
<26% <26%

Standard Power with Self-Diagnostics Option ( Fully Discharged Battery) - LED Exits
Red Letters Single Face
Red Letters Single Face with Remote
Green Letters Single Face
Green Letters Single Face with Remote

8.4W
9.8W
9.1W
11.2W

8.5W
9.5W
9.0W
10.5W

.08A
.09A
.09A
.10A

.04A
>.82
>.82
<31%
.04A
>.86
>.84
<30%
.04A
>.86
>.85
<27%
.05A
>.90
>.88
<25%
Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced
mately 1.5 Watts in the standby operating mode

<31%
<30%
<27%
<26%
by approxi-

> Centerpin Torx tamper
resistant screws on sides
of faceplate
> NFPA compliant knockout
chevrons
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching, lowvoltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/ power
indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA, UL
FTBR Listed (with “2C”
option), UL Listed as suitable for floor proximity
installation, most state and
local codes

COOPER LIGHTING

47

DESCRIPTION

DIMENSIONS

The Sure-Lites Pinnacle Family
of Die Cast Aluminum Exits
combine strength, durability
and aesthetics. The fully
recessed CAR Series offers a
very clean unobtrusive look.
The die cast faceplate is
offered in four finishes.

EXIT SIGNS >

Architectural

SURE-LITES®

CAR SERIES
Die Cast
AC Only
Recessed
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N

> Dual Voltage Input
120/277 VAC, 60 Hz
> Die cast aluminum face
plate
> LED, Compact Fluorescent,
or Incandescent lamping
> AC incandescent: two 20W
T6 1/2 intermediate base
lamps
> AC fluorescent: two 5W
F5TT compact fluorescent
lamps
> NFPA 101 compliant
knockout chevrons allow
quick conversion to
directional signs

S A M P L E N U M B E R : C A R 2 10 0 0 0 G B

CAR
Family
CAR=Die Cast
Aluminum Exit
Recessed Mount
Series
2=AC Only, Incandescent
4=AC Only, Fluorescent
6=AC Only, LED (120/277)

Face Options
1=Single

Battery
00=No Battery

> Rough-in back box for
recessed mounting

Factory
Options
00=No Options
65=Tamperproof
Screws
85=Vandal Shield
95=AC Only Fire Alarm
Interface2
Letter Colors
R=Red
G=Green
RWO=Red on White1
(except LED)
GWO=Green on White1
(except LED)
WRO=White on Red1
(except LED)
WGO =White on Green1
(except LED)
O=Open Face1
(except LED)

Faceplate
Finishes
Blank=Brushed
Aluminum
W=White
B=Black
BZ=Bronze

Factory Options
2C= Two Circuit Operation

Voltage
Blank=120V
77=277V (Incandescent
and Fluorescent only)

Accessories (Order Separately)
059012SP=Tamperproof Screwdriver Bit
VRSD=Vandal Resistant Screwdriver

> Hanger bars supplied
standard for mounting
> Faceplate secures to
rough-in box with torsion
springs
> Stencil and open face
signs available

Energy Data

Incandescent Exits - 20W Lamps
Fluorescent Exits - 5W Lamps

> Damp Location Listed
LED Exits - Single Face

Input Power:
Input Current (Max.):
120V 277V
120V 277V
Incandescent Exits
40W
42W
.33A
.16A
Fluorescent Exits
14W
21W
.29A
.32A
LED Exits
6.7W 6.8W
.07A
.03A

Power Factor:
120V 277V

T.H.D.:
120V 277V

-

-

-

-

>.40

>.24

<14%

<11%

>.79

>.79

<30%

<31%

> UL 924 Listed, UL FTBR
Listed (consult Cooper
Lighting Representative
for applicable fixture
types), Life Safety NFPA
101, NEC/OSHA, most
state and local codes
> Suitable for floor proximity
installation

Notes: AC compact fluorescent CAR Series Exits cannot be converted to self-powered emergency.
1Available

48

COOPER LIGHTING

only for incandescent and fluorescent versions. RWO, GWO, WRO, and WGO are open face styles with “EXIT” legend.
Use “O” option for ordering special wording-lenses ordered separately (consult Cooper Lighting Representative).
2AC Only Fire Alarm Interface Option available on incandescent exits only.

DIMENSIONS

DESCRIPTION

Architectural

The Sure-Lites Pinnacle Family
of Die Cast Aluminum Exits
combine strength, durability
and aesthetics. The fully
recessed CAR Series offers a
very clean unobtrusive look.
The die cast faceplate is
offered in four finishes.

EXIT SIGNS >

SURE-LITES®

CAR SERIES
Die Cast
Self-powered
Recessed
EXIT LIGHTING
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : C A R 3 10 0 2 0 R W

> Dual-voltage input
120/277VAC, 60Hz

CAR
Family
CAR=Die Cast
Aluminum Exit
Recessed Mount
Series
3=Self-Powered,
Incandescent
5=Self-Powered,
Fluorescent
7=Self-Powered, LED

Face Options
1=Single

Battery
00=Lead Calcium Battery
(CAR3 & CAR5 Only)
70=Nickel Cadmium Battery

Factory
Options
00=No Options
20=DC Flasher2
30=DC Flasher/
Buzzer2
65=Tamperproof
Screws
85=Vandal Shield
90=DC Only Fire
Alarm Interface2

Faceplate
Finishes
Blank=Brushed
Aluminum
W=White
B=Black
BZ=Bronze
Voltage
Blank=120/277V

Factory Options
SD=Self Diagnostics
(Incandescent & LED Only)

Accessories (Order Separately)
059012SP=Tamperproof
Screwdriver Bit
VRSD=Vandal Resistant Screwdriver

Letter Colors
R=Red
G=Green
RWO=Red on White1
(except LED)
GWO=Green on White1
(except LED)
WRO=White on Red1
(except LED)
WGO=White on Green1
(except LED)
O=Open Face1
(except LED)

> Die cast aluminum face
plate
> LED, Compact Fluorescent,
or Incandescent lamping
> AC Incandescent: two 20W
T6 1/2 intermediate base
lamps; DC Incandescent:
two 6V, 3.6W lamps
> AC and DC Fluorescent:
Two 5W F5TT compact
fluorescent lamps
> Lead Calcium or Premium
Nickel Cadmium battery
> NFPA 101 compliant
knockout chevrons allow
quick conversion to
directional signs
> Rough-in back box for
recessed mounting

Wa tt a g e R a t i n g s
Lead Calcium Battery=10.8W for 1 1/2 hrs.

Nickel Cadmium Battery=15.0W for 1 1/2 hrs.

Energy Data

(Charge Mode, Fully Discharged Battery): Sealed Lead Calcium Battery
Input Power:
Input Current (Max.): Power Factor:
T.H.D.:
120V
277V
120V
277V
120V
277V
120V
277V
Incandescent Exits - 20W lamps
53W
51W
.45A
.19A
>.99
>.98
<9%
<10%
Fluorescent Exits-5W Lamps
29W
30W
.40A
.16A
>.61
>.66
<12% <11%
LED Exits
8.0W
8.0W
.09A
.04A
>.75
>.75
<34% <34%
Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by
approximately 12 Watts in the standby operating mode
Sealed Nickel Cadmium Battery
Incandescent Exits - 20W Lamps
45W
43W
.38A
.16A
>.99
>.99
<7%
<7%
Fluorescent Exits - 5W Lamps
20W
21W
.36A
.15A
>.48
>.52
<15%
<14%

> Faceplate secure to rough
in box with torsion springs
> Stencil and open face
signs available
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA, UL
FTBR Listed, most state
and local codes
> Suitable for floor proximity
installation

1Available

only for incandescent and fluorescent versions. RWO, GWO, WRO, and WGO are open face styles with “EXIT” legend. Use
“O” option for ordering special wording-lenses ordered separately (consult Cooper Lighting Representative).
Flasher, DC Flasher/Buzzer, DC Only Fire Alarm Interface Options available on incandescent exits only.

2DC

COOPER LIGHTING

49

DESCRIPTION

EXIT SIGNS >

Commercial

SURE-LITES®

LPX SERIES
Po l yc a r b o n a te
AC Only

DIMENSIONS

The LPX Series LED Exit is an
economical, yet attractive, alternative to metal exits. Its contemporary round corner styling,
designer white finish, and consistent family appearance
enables it to blend with any
decor. The tough injection molded polycarbonate materials
resist discoloration.
The canopy and chevron directional indicators, are of snap-fit
construction to facilitate installation. The under 5-minute installation time makes it the fastest
installed exit on the market
today.

4 1/2"
[114mm]

6" [152mm]
3/4"
[19mm]

7 1/2"
[190mm]

2 1/8"
[54mm]

13" [330mm]

S e l f - Powe re d
EXIT LIGHTING

> Dual-voltage Input 120/277 VAC,
60Hz, isolation transformer
> Injection molded polycarbonate
housing
> LED lamping
> Premium Nickel Cadmium
battery (Self Powered)
> Fully charged in 24 hours
(Self-Powered Exits)
> Snap-fit canopy included
> Snap-out or snap-in chevron
directional indicators
> Knockout provided on housing
for surface attachment
> Universal exits can be field
configured as single face or
double face (ceiling, wall, or end
mounting)
> Self-powered Exit features
line-latching, solid-state voltage
limited charger, solid-state
switching, brownout circuit,
low-voltage disconnect, overload/short-circuit protection,
test switch/power indicator light
> UL Damp Location Listed (AC
Only & Self-Diagnostic versions)
> Optional 2C (Two circuit, FTBR)
available in 120/277 VAC in
standard and emergency
operation (AC Only Exits)
> UL 924 Listed, Life Safety NFPA
101, CSA Certified, NEC/OSHA,
most state and local codes,
suitable for floor proximity
installation
> Patent No. 5,735,498 and
5,678,336

50

COOPER LIGHTING

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: LPX70RWH

LPX
Family
LPX=Polycarbonate
Exit

Letter
Colors
R=Red
G=Green
(White
Only)
DG=Premium
Deep
Green

Series
6=AC only with LED
7=Self-Powered with
LED

Housing
Finishes
WH=White
BK=Black

Face Options
0=Universal

Options
2C=Two Circuit
Option
(FTBR)
(LPX6 Only)
SD=Self
Diagnostics
(Red and
Deep Green,
White
Housing
Only. LPX7
Only)

Battery
Blank=No Battery (LPX6)
Blank=Nickel Cadmium Battery (LPX7)

Accessories
(Order Separately)
CCX18PKWH=18”
Pendant Kit, White
CCX18PKHTWH=18”
Hang True Pendant Kit,
White
CCX18PKBK=18”
Pendant Kit, Black
CCX18PKHTBK=18”
Hang True Pendant Kit,
Black
WG10=Surface, Wire
Guard
WGS11=Ceiling, End
Wire Guard
VS1=Polycarbonate
Vandal Shield
VS1WP=Polycarbonate
Vandal Shield
Weather Proof

E n e rgy Da t a – S e l f - Powe re d E x i t s

Charge Mode (Fully Discharged Battery): Sealed Nickel Cadmium Battery
Input Power:
Input Current (Max.):
Power Factor:
T.H.D.:
120V

277V

120V 277V
LED Exits

120V

277V

120V

LED Exits -Red Letters
LED Exits Green
LED Exits-Red Letters SD

2.8W 2.9W
6.0W 6.4W
1.7W 1.7W

.03A
.02A
.09A
.04A
.03A
.01A
Premium

> .81
> .58
>.63

> .77
> .56
>.64

< 32% < 46%
< 42% < 45%
<43% <48%

Premium Deep Green
Premium Deep Green SD

4.0W
3.1W

> .41
>.34

> .41
>.36

< 48% < 49%
<63% <67%

4.0W
3.0W

.08A
.08A

.04A
.04A

277V

Energy Data – AC Only Exits

Input Power:

Input Current (Max.):

120V

277V

120V 277V
LED Exits

LED Exits -Red Letters
LED Exits -Green Letters

2.4W
5.6W

2.5W
5.9W

.03A
.08A
Premium

Premium Deep Green

2.6W

2.6W

.08A

Power Factor:

T.H.D.:

120V

277V

120V

277V

.02A
.04A

> .78
> .55

> .73
> .53

< 33% < 48%
< 43% < 45%

.04A

> .28

> .28

< 51% < 53%

DESCRIPTION

DIMENSIONS

The tough injection molded
polycarbonate materials resist
discoloration due to age and
ultraviolet radiation. The
canopy and chevron directional indicators are of snap-fit
construction to facilitate installation. Reliable and labor-saving push-in AC connectors are
standard to further improve
the installation time. The under
5-minute installation time
makes it the fastest installed
exit on the market today.

Commercial

The LPX Series LED Exit is an
economical, yet attractive,
alternative to metal exits. Its
contemporary round corner
styling, designer white finish,
and consistent family appearance enables it to blend with
any decor.

EXIT SIGNS >

SURE-LITES®

LPX(H) SERIES
EXITS
Po l yc a r b o n a te
S e l f - Powe re d
H i g h Powe r
(Remote Capacity)
Double Heads
EXIT LIGHTING

> Dual Voltage Input 120/277
VAC, 60Hz, isolation
transformer

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: LPX70RWHDH

> Injection molded, high impact,
polycarbonate housing
> LED lamping

Family
LPX=Polycarbonate
Exit
LPXH=High Power*
(Remote
Capacity)

Letter
Colors
R=Red
DG=Premium
Deep
Green

Housing
Finishes
WH=White
BK=Black
(Red Only)

Voltage
Blank=120/277
VAC

Heads
Blank=No
Heads
(LPXH
Only)
DH=Double
Heads

Series
7=Self-Powered with
LED
Face Options
0=Universal

Options
SD=Self-Diagnostics
(Red Only)

Battery
Blank=Lead Calcium

Accessories
(Order Separately)
CCX18PKWH=18” Pendant
Kit, White
CCX18PKHTWH=18”
Hang True Pendant Kit,
White
WG10=Wall Mount (without
heads)
WGS11=Ceiling or End
Mount (without
heads)
WG12=Wall Mount (with
heads)
WG17=Ceiling or Wall
Mount (with heads)
VS1=Polycarbonate Vandal
Shield (without heads)
VS2=Polycarbonate vandal
shield (with heads)
LPX1HWH=Head assembly,
White (LPXH
only)

Energy Data

Standby Mode (Fully charged Battery): Sealed Lead Calcium Battery
Input Power:
Input Current (Max.):
Power Factor:

LED Exits -Red Letters
LED Exits-Red Letters SD

120V

277V

120V 277V
LED Exits

4.9W
4.0W

4.7W
3.9W

.07A
.06A
Premium

.03A
.02A

T.H.D.:

120V

277V

120V

> .59
>.57

> .64
>.58

< 45% < 44%
<40% <46%

Premium Deep Green

277V

3.1W 2.9W
.06A
.02A
> .41 > .44
< 49% < 53%
Charge Mode (Discharged Battery): Sealed Lead Calcium Battery
Input Power consumption is increased by approximately 2.7 watts in the charge operating mode for red units and 3.4
watts for green units

> Heads DC: 6V, 5.4W
incandescent wedge base
lamps. PAR 36 Style
> Sealed Lead Calcium Battery,
Maintenance Free, Long Life,
Full Recharge Time, 24 hours
(max.); 48 hours (max.) for
LPXH units
> Universal exits can be field
configured as single face or
double face (ceiling, wall or
end mounting)
> Knockout provided on housing
for surface conduit attachment
> Snap-fit canopy with captive
mounting screws included
with all exits
> Line-Latching, Solid-State
Voltage Limited Charger,
Solid-State Switching,
Brownout Circuit, Low- Voltage
Disconnect, Overload/Short
Circuit Protection, Test Switch/
Power Indicator Light, Push-in
AC power connectors facilitate
installation
> Damp Location Listed
Standard
> UL 924, UL 924, 4 hour rated
(LPXH Units), Life Safety NFPA
101, CSA Certified, NEC/OSHA,
suitable for floor proximity
installation

Wa tt a g e R a t i n g s
LPXH* with double-heads (DH) has remote capacity of 11 watts for 1 1/2 hrs. No remote capacity for 4 hrs.
LPXH has Remote Capacity of 22 watts for 1 1/2 hrs. and 11 watts for 4 hrs.

COOPER LIGHTING

51

DESCRIPTION

EXIT SIGNS >

Commercial

SURE-LITES®

CCX SERIES

DIMENSIONS

The CCX Series Contractor’s
Choice Exit is an economical,
attractive, alternative to metal
exits. Contemporary round corner styling, designer
finish, and consistent family
appearance enables it to blend
with any decor. The tough
injection molded polycarbonate materials resist discoloration. The canopy and
chevron directional indicators
are of snap-fit construction to
facilitate installation.

Po l yc a r b o n a te
AC Only
EXIT LIGHTING
O R D E R I N G I N F O R M AT I O N

> Dual voltage input 120/277
VAC, 60 Hz
> Injection molded, high
impact, polycarbonate
housing
> Designer white textured
finish standard (Black
Available-Fluorescent Only)
> LED, Fluorescent or
Incandescent lamping
> LED: long life LED lamp
modules
> Fluorescent: two 5W F5TT
lamps
> Incandescent: two 145V,
15W T6 lamps
(candelabra base)

SAMPLE NUMBER: CCX20RWH

CCX
Family
CCX=Contractor’s
Choice Exit
Series
2=AC Only with 145V,
15W T-6 AC
Incandescent Lamps
4=AC Only with 5W F5TT
Compact Fluorescent
Lamps
6=AC only with
LED Lite Stix™
Face Options
0=Universal
1=Single Face
2=Double Face

Factory
Options
Blank=No Options
65=Tamperproof
Screws
95=AC Fire Alarm
Interface (for
Incandescent &
LED)
Letter Colors 1
R=Red
G=Green
RWO=Red on White1
GWO=Green on White1
WRO=White on Red1
WGO=White on Green1
O=Open Face1

Housing Finishes
BK=Black
(Fluorescent Only)
WH=White
Voltage
Blank=120 VAC
7=120/277 VAC
(for Incandescent
& Fluorescent)
7=277 VAC
(LED only)
47= 120/347 VAC
(Incandescent only)

Battery
Blank=No Battery

> Ceiling, wall or end
mounting
> Universal J-box mounting
pattern
> Push-in power connectors
facilitate installation
> Snap-fit canopy included
> Components are snap-fit
construction, reinforcing ribs
add strength
> Snap-out chevron directional
indicators
> UL FTBR Listed with 2C
option (7W Lamps Only.
Fluorescent Exits Only.)
> Damp Location Listed

Factory Options
2C=Two Circuit Operation includes 7W lamps
(Fluorescent Only)
C7=130V, 7W C-7 AC
Incandescent Lamps
(Incandescent Only)
7W=7W Compact Fluorescent
Lamps (Fluorescent Only)

Accessories (Order Separately)
CCX18PKBK=18” Pendant Kit, Black
CCX18PKWH=18” Pendant Kit, White
CCX18PKHTBK=18” Hang-True
Pendant Kit, Black
CCX18PKHTWH=18” Hang-True
Pendant Kit, White
CCX277=277V Conversion Kit
VRSD=Tamper Resistant Screwdriver
WG10=Surface, Wire Guard
WGS11=Ceiling, End Wire Guard
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield Weatherproof

Energy Data

Incandescent Exits
Input Power:
Input Current(Max.):
120V 277V
120V 277V
Incandescent Exits -15W Lamps
23.1W 30.0W
.19A .19A
Incandescent Exits -7W Lamps
12.5W 19.6W
.10A .17A
Fluorescent Exits
Fluorescent Exits -5W Lamps
16.3W 24.4W
.14A .33A
Fluorescent Exits - 7W Lamps
18.0W 26.2W
.15A .31A
Fluorescent Exits -7W Lamps (2C Option) 8.7W 13.3W
.16A .14A
All ratings are per circuit
LED Exits
LED Exits- Red Letters
1.8W 2.6W
.09A .11A
LED Exits - Green Letters
3.2W 4.5W
.08A .10A

Power Factor:
120V 277V

T.H.D.:
120V 277V

>.97
>.97
>.45

>.27
>.33
>.34

<20% <25%
<23% <29%
<11% <28%

>.17
>.33

>.09
>.15

<18% <10%
<28% <16%

> UL 924 Listed, Life Safety
NFPA 101, CSA Certified,
NEC/OSHA, most state and
local codes, suitable for floor
proximity installation

1Available

only for incandescent and fluorescent versions. GWO, RWO, WGO, and WRO are open face style lenses with “EXIT” legend. Use “O”
option for ordering special wording-lenses ordered separately (consult your Cooper Lighting Representative).

52

COOPER LIGHTING

DIMENSIONS

DESCRIPTION

Commercial

The CCX Series Contractor’s
Choice Exit is an economical,
attractive, alternative to metal
exits. Contemporary round
corner styling, designer
finish, and consistent family
appearance enables it to blend
with any decor. The tough
injection molded polycarbonate materials resist discoloration. The canopy and
chevron directional indicators
are of snap-fit construction to
facilitate installation.

EXIT SIGNS >

SURE-LITES®

CCX SERIES
Po l yc a r b o n a te
S e l f - Powe re d
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N

> Dual-voltage input
120/277VAC, 60Hz

SAMPLE NUMBER: CCX30RWHSD

CCX
Family
CCX=Contractor’s
Choice Exit
Series
3=Self-Powered with
145V, 15W T-6 AC
Incandescent Lamps
5=Self-Powered with
5W F5TT Compact
Fluorescent Lamps
7=Self-Powered with
LED Lite Stix™
Face Options
0=Universal
1=Single Face
2=Double Face
Battery
Blank=Lead Calcium
70=Nickel Cadmium

Factory
Options
Blank=No Options
20=Flasher
30=Flasher / Buzzer
65=Tamperproof
Screws
90=Self-Powered
Fire Alarm
Interface (except
fluorescent)
Letter Colors 1
R=Red
G=Green
RWO=Red on White1
GWO=Green on White1
WRO=White on Red1
WGO=White on Green1
O=Open Face1

Housing Finishes
BK=Black
(Fluorescent Only)
WH=White
Voltage
Blank=120/277 VAC
47=120/347 VAC
(Series 3 and 7 only)

Factory Options
C7=130V, 7W C-7 AC
Incandescent Lamps
(Incandescent Only)
7W=7W Compact Fluorescent
Lamps (Compact fluorescent
Only)
SD=Self-Diagnostics

Accessories (Order Separately)
CCX18PKBK=18” Pendant Kit, Black
CCX18PKWH=18” Pendant Kit, White
CCX18PKHTBK=18” Hang-True
Pendant Kit, Black
CCX18PKHTWH=18” Hang-True
Pendant Kit, White
VRSD=Tamper Resistant Screwdriver
WG10=Surface, Wire Guard
WGS11=Ceiling, End Wire Guard
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield Weatherproof

> Injection molded, high
impact, polycarbonate
housing
> Designer white textured finish
standard (black availablefluorescent only)
> LED, Fluorescent, or
Incandescent lamping
> AC LED: long life LED lamp
modules
> AC fluorescent: two 5W
F5TT lamps
> AC incandescent: two
145V, 15W T6 lamps
(candelabra base)
> DC: two 6V, 3.6W lamps
(white housing); three 6V,
3.6W lamps (black housing)
> Lead Calcium or Premium
Nickel Cadmium battery
> Ceiling, wall or end
mounting

Energy Data

Charge Mode (Discharged Battery): Sealed Lead Calcium Battery
Input Power:
Input Current(Max.): Power Factor:
120V
277V
120V 277V
120V 277V
Incandescent Exits -15W Lamps
32W
32W
.28A
.12A
>.95 >.95
Incandescent Exits -7W Lamps
22W
22W
.20A
.09A
>.91 >.90
Fluorescent Exits -5W Lamps
25W
25W
.23A
.10A
>.90 >.90
Fluorescent Exits - 7W Lamps
28W
28W
.25A
.11A
>.93 >.92
LED Exits- Red Letters
10.4W 10.8W
.10A
.04A
>.89 >.88
LED Exits - Green Letters
11.9W 12.3W
.10A
.05A
>.96 >.94

T.H.D.:
120V 277V
<17% <19%
<24% <26%
<21% <23%
<23% <23%
<45% <48%
<29% <33%

Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by
approximately 7.5 Watts
in the standby operating mode
Sealed Nickel Cadmium Battery
Incandescent Exits -15W Lamps
26W
26W
.24A
.10A
>.94 >.93
<17% <19%
Incandescent Exits -7W Lamps
15.8W 15.9W
.15A
.06A
>.84 >.83
<29% <27%
Fluorescent Exits -5W Lamps
19.9W 19.6W
.20A
.08A
>.85 >.84
<29% <31%
Fluorescent Exits - 7W Lamps
22W
21W
.21A
.09A
>.89 >.89
<31% <31%
LED Exits- Red Letters
4.8W
4.7W
.05A
.02A
>.76 >.73
<63% <68%
LED Exits - Green Letters
6.1W
6.0W
.06A
.03A
>.88 >.85
<47% <52%

> Universal J-box mounting
pattern
> Components are snap-fit
construction, reinforcing
ribs add strength
> Snap-fit canopy included
> Suitable for floor proximity
installation
> Line-latching, Solid-State
voltage limited charger ,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/
short-circuit protection, test
switch/power indicator light
> UL 924 Listed, life safety
NFPA 101, CSA Certified,
NEC/OSHA, most state and
local codes

1Available

only for incandescent and fluorescent versions. GWO, RWO, WGO, and WRO are open face style lenses with “EXIT” legend.
Use “O” option for ordering special wording-lenses ordered separately (consult your Cooper Lighting Representative).

COOPER LIGHTING

53

DESCRIPTION

DIMENSIONS

The CCX Series Contractor’s
Choice Exit is an economical,
attractive, alternative to metal
exits. Contemporary round
corner styling, designer
finish, and consistent family
appearance enables it to blend
with any decor. The tough
injection molded polycarbonate materials resist discoloration.
The canopy and chevron
directional indicators, are of
snap-fit construction to facilitate installation.

EXIT SIGNS >

Commercial

SURE-LITES®

CCX SERIES
CCXH SERIES
O R D E R I N G I N F O R M AT I O N

Po l yc a r b o n a te
S e l f - Powe re d
H i g h Powe r
(Remote Capacity)
Double Heads
EXIT LIGHTING

> Dual-voltage input
120/277VAC, 60Hz
> Injection molded, high impact,
polycarbonate housing
> Designer white textured finish
standard (black availablefluorescent only)
> LED, Fluorescent, or
Incandescent lamping
> AC LED: long life LED lamp
modules
> AC fluorescent:
two 5W F5TT lamps
> AC Incandescent:
two 145V, 15W T6 lamps
(candelabra base)
> DC: two 6V, 3.6W lamps
(three for black housing)
> Heads: two 6V, 9W PAR36
style lamps (7.2W for black)
housing) (specify DH in
catalog number)
> Lead Calcium batteries
> Ceiling, wall or end
mounting
> Universal J-box mounting
pattern
> Components are Snap-fit
construction, reinforcing ribs
add strength
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/
short-circuit protection, test
switch/ power indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA, most
state and local codes

SAMPLE NUMBER: CCX31RWHDH

Family
CCX=Contractor’s
Choice Exit
CCXH=High Output
Remote capacity
Series
3=Self-Powered with
145V, 15W T-6 AC
Incandescent Lamps
5=Self-Powered with
5W F5TT Compact
Fluorescent Lamps
7=Self-Powered with
LED Lite Stix™
Face Options 1
0=Universal
1=Single Face
2=Double Face

Factory
Options
Blank=No Options
20=Flasher
30=Flasher / Buzzer
65=Tamperproof
Screws
90=Self-Powered Fire
Alarm Interface
(for Incandescent
& LED)
Letter Colors 2
R=Red
G=Green
RWO=Red on White2
GWO=Green on White2
WRO=White on Red2
WGO=White on Green2
O=Open Face2

Battery
Blank=Lead Calcium

Housing
Finishes
BK=Black
(Fluorescent
Only)
WH=White

Factory Options
C7=130V, 7W C-7 AC
Incandescent Lamps
(Incandescent only)
7W=7W Compact Fluorescent
Lamps (Fluorescent only)
SD=Self-Diagnostics

Voltage
Blank=120/277 VAC
47= 120/347 VAC (for
Incandescent
& LED)

Heads
DH=Double Heads
DH0=Remote Capacity
No Heads
DH1L=Single Head Left
(near “E” in “EXIT”)
DH1R=Single Head Right
(near “T” in “EXIT”)
DHMRT=MR16 Heads
(5W Standard)
DHSQ=Square Heads
(5.4W Standard)

Accessories (Order Separately)
CCXDHMBBK=CCX-DH Ceiling Mounting
Bracket, Black
CCXDHMBWH=CCX-DH Ceiling
Mounting Bracket, White
VRSD=Tamper Resistant Screwdriver
WG2=Wire Guard
VS2=Polycarbonate Vandal Shield
VS2WP=Polycarbonate Vandal Shield Weatherproof

Energy Data

Charge Mode (Discharged Battery): Sealed Lead Calcium Battery
Input Power:
Input Current(Max.): Power Factor:
T.H.D.:
120V 277V 347V
120V 277V 347V
120V 277V
120V 277V
Incandescent Exits -15W Lamps
35W 34W
22W
.30A .13A .13A
>.96 >.95
<16% <18%
Incandescent Exits -7W Lamps
24W 25W 29.1W
.22A .10A .14A
>.93 >.92
<21% <23%
Charge Mode (Discharged Battery): Sealed Lead Calcium Battery
Fluorescent Exits -5W Lamps
28W 28W
.25A .11A
>.93 >.93
<19% <21%
Fluorescent Exits - 7W Lamps
30W 30W
.26A .12A
>.94 >.93
<21% <23%
Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 5 Watts
in the standby operating mode
Charge Mode (Discharged Battery): Sealed Lead Calcium Battery
LED Exits- Red Letters
12.6W 13.2W 7.0W
.11A .05A .09A
>.91 >.91
<39% <42%
LED Exits - Green Letters
15.8W 15.4W 8.4W
.14A .06A .09A
>.97 >.96
<25% <29%
Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 5 Watts in the standby operating mode

WAT TA G E R AT I N G S
CCX-DH

1Exits

Lead Calcium Battery=27W for 1 1/2 hrs.; 24W for 2 hrs.

CCXH-DH

Lead Calcium Battery=32W for 1 1/2 hrs.

using two faces must also use CCXDHMB Mounting Bracket for ceiling mounting (included in Universal and Double Face configurations). 2Available only for incandescent and fluorescent versions. GWO, RWO, WGO, and WRO are open face style lenses with “EXIT”
legend. Use “O” option for ordering special wording-lenses ordered separately (consult your Cooper Representative).

54

COOPER LIGHTING

DIMENSIONS

DESCRIPTION
Wa l l M o u n t

End Mount

Commercial

The EEX Series Surface
Mounted Edge-lit Exit, with
the Tri-Mount™ System, provides an attractive yet easy to
install universal edge-lit exit
sign. The crystal clear wedge
shape lens panel provides
excellent light distribution,
exit visibility and quick snapin installation. Long life, energy-efficient LED lamps reduce
energy costs and eliminate
routine lamp maintenance.

EXIT SIGNS >

SURE-LITES®

EEX SERIES

The under-five-minute installation time makes it the
fastest installed edge-lit exit
on the market today.

Edge-Lit
S u r fa c e
AC Only
S e l f - Powe re d

Note: Special wording
available; consult
your Cooper Lighting
Representative.

EXIT LIGHTING

> Dual-voltage Input 120/277
VAC, 60Hz, optional 2C
(FTBR) available
(EEX6 only)
> Injection molded
polycarbonate housing
> Injection molded, highimpact, clear acrylic panel

O R D E R I N G I N F O R M AT I O N – C O M P L E T E U N I T
SAMPLE NUMBER: EEX71R

> LED lamping

EEX
Family
EEX=Edgelit
Exit
Series

Series
6=LED
Lamps,
AC Only
7=LED
Lamps,
SelfPowered

Face Options
1=Single Face
2=Double
Face

Chevron Direction
Letter/
Background Blank=Universal
Stick-On
Color 1
Chevrons
R=Red
G=Green

Battery
Blank=No Battery
(EEX6)
Blank=Nickel
Cadmium
(EEX7)
Housing Trim
Finish
Blank=White Only

Options
2C2=Two Circuit Option FTBR (EEX6 only)
Accessories (Order Separately)
WG=Choose size of wire guard
desired from accessories
sheet

> Sealed nickel cadmium,
maintenance free, long life
battery (EEX7 only)
> Full Recharge Time,
24 hrs. (max.)
> Components are snap-fit
construction to facilitate
under 5-minute installation
> Tri-mount system for ceiling,
wall or end mounting
> Universal, field installable
chevrons

E n e rgy Da t a — S e l f - Powe re d E x i t s

Charge Mode (Discharged Battery): Sealed Nickel Cadmium Battery
Input Power:
Input Current (Max.): Power Factor:
120V
277V
120V 277V
120V 277V
LED Exits
LED Exits Red Lights
LED Exits Green Lights

6.5W
4.0W

6.6W
4.1W

.08A
.07A

.04A
.03A

>.67
>.47

>.66
>.47

T.H.D.:
120V 277V
<41% <43%
<48% <50%

Energy Data — AC Only

Input Power:

LED Exits -Red Letters
LED Exits -Green Letters

120V

277V

5.9W
3.2W

6.0W
3.3W

Input Current (Max.):
120V 277V
LED Exits
.08A
.07A

.04A
.03A

Power Factor:

T.H.D.:

120V

277V

120V

277V

>.62
>.39

>.62
>.39

<43%
<51%

<45%
<53%

> Universal background mirror and white inserts
included
> Universal J-box
mounting pattern
> Self-powered Exits feature
line-latching, solid-state
voltage limited charger,
solid-state switching,
brownout circuit, low-voltage disconnect, overload/
short-circuit protection, test
switch / power indicator light
> Damp Location Listed
(AC only)
> UL 924 Listed, UL Listed for
floor proximity, UL Listed for
Two Circuit (FTBR) (EEX6
only), Life Safety NFPA 101,
CSA Certified, NEC/OSHA,
most state and local codes

1Universal

background clear, white insert and mirror insert included. 2Universal 120/277V normal and 120/277V emergency.

COOPER LIGHTING

55

DIMENSIONS

DESCRIPTION

The EUS Series surface mounted
Edge-lit Exit provides an attractive
yet easy to install universal edgelit
exit sign. The crystal clear lens
panel provides excellent light distribution and exit visibility. Long
life, energy efficient LED lamps
reduce energy costs and eliminate
routine lamp maintenance.

EXIT SIGNS >

Commercial

SURE-LITES®

EUS SERIES
Edge-Lit
S u r fa c e

All EUS Series Edge-lit Exits are provided with universal mounting capability (ceiling, wall or end), universal
exit lens (single and double face), and
universal, field installable chevrons.
The EUS is the most versatile edge-lit
exit in the market today.

AC Only
S e l f Powe re d
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N - C O M P L E T E U N I T
SAMPLE NUMBER: EUR70R

> Dual Voltage Input

120/277 VAC, 60 Hz
> Anodized Aluminum

housing, clear acrylic
panel or faceplate
> LED lamping
> Nickel Cadmium battery

EU

S

Family
EU=Universal
Edgelit
Exit
Series

(Self-Powered)
S=Surface Mount

> Universal Surface Mount:

Series
60=LED
Lamps,
AC Only
70=LED
Lamps,
SelfPowered

Face Options
Blank=Universal
Face (Single &
Double face)

Battery
Blank=Lead Acid
(Self-Powered
Only)

Chevron Direction
Blank=Universal
Stick-On
Chevrons

Housing Trim
Finish
Blank=Anodized
Aluminum

Ceiling, Wall or End
> Single and double face

panels standard

Letter/
Background
Color1
R=Red
G=Green

> Universal, Field Installable

Chevrons
> Mirror background

included with double
face exits
> Test Switch/Power

Indicator Light
(Self powered)
> UL 924 Listed, ETL Listed,

Life Safety NFPA 101,
most state and local codes

E N E R G Y D ATA
Charge Mode (Fully Charged Battery):

LED Exits - Red
LED Exits - Green
LED Exits - Red
LED Exits - Green

56

COOPER LIGHTING

Sealed Lead Acid Battery
Input Power:
Input Current(Max.):
120V
277V
120V
277V
3.6W
3.1W
.03A
.02A
2.9W
2.7W
.02A
.02A
AC Only
3.9W
3.5W
.03A
.02A
3.1W
2.8W
.02A
.02A

Voltage Blank=Dual
Voltage,
120/277V

DESCRIPTION

DIMENSIONS

Commercial

The EUR Series Recessed
Edgelit Exit provides an attractive yet easy to install universal
edgelit exit sign. The crystal
clear lens panel provides excellent light distribution and exit
visibility. Long life, energy efficient LED lamps reduce energy
costs and eliminate routine
lamp maintenance.

EXIT SIGNS >

SURE-LITES®

EUR SERIES
E d ge - L i t
Recessed
AC O n l y
S e l f - Powe re d
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N - C O M P L E T E U N I T
SAMPLE NUMBER: EUR70R

EU

> Dual Voltage Input
120/277 VAC, 60 Hz

R

Family
EU=Universal
Edgelit
Exit
Series
R=Recessed Mount
(Ceiling access
mount only)

Series
60=LED
Lamps,
AC Only
70=LED
Lamps,
SelfPowered

Face Options
Blank=Universal
Face (Single &
Double face)

Battery
Blank=Lead Acid
(Self-Powered
Only)

Chevron Direction
Blank=Universal
Stick-On
Chevrons

Housing Trim Finish
Blank=Anodized
Aluminum

Letter/Background Color1
R=Red
G=Green

Voltage Blank=
Dual Voltage, 120/277V

> Anodized Aluminum
faceplate, clear acrylic
panel
> LED lamping
> Nickel Cadmium battery
(Self-Powered)
> Recessed ceiling mount
(accessible ceiling only)
> Single and double face
panels standard
> Universal, Field Installable
Chevrons
> Mirror background
included with double
face exits
> Test Switch/Power
Indicator Light
(Self powered)

E N E R G Y D ATA
Charge Mode (Fully Charged Battery):

LED Exits - Red
LED Exits - Green

Input
120V
3.6W
2.9W

LED Exits - Red
LED Exits - Green

3.9W
3.1W

Sealed Lead Acid Battery
Power:
Input Current(Max.):
277V
120V
277V
3.1W
.03A
.02A
2.7W
.02A
.02A
AC Only
3.5W
.03A
.02A
2.8W
.02A
.02A

> UL 924 Listed, ETL Listed,
Life Safety NFPA 101,
most state and local codes

COOPER LIGHTING

57

DESCRIPTION

The INCX Series Incandescent Exit is an economical, yet attractive, alternative to metal exits. The tough
injection molded white thermoplastic material resists discoloration due to age and ultraviolet radiation.
The structural components are made even stronger with reinforcing ribs throughout. All components,
including canopy and chevron directional indicators, are of snap-fit construction to facilitate installation.

EXIT SIGNS >

Commercial

SURE-LITES®

DIMENSIONS

INCX20RGWH

4 13/16"
[122mm]

5 1/2" [140mm]
7/8"
[22mm]

7 3/4"
[196mm]

INCX SERIES
T h e rm o p l a s t i c
AC Only
S e l f - Powe re d

11 3/4" [298mm]

INCX30RGWH

2 1/2"
[64mm]
4 13/16"
[122mm]

5 1/2" [140mm]

EXIT LIGHTING

1"
[25mm]

> 120 VAC, 60Hz Input Voltage
(INCX20RGWH); 120/277 VAC,
60Hz (INCX30RGWH)
> Thermoplastic housing

10"
[254mm]

> Designer white textured
finish
> Incandescent: Two 130V,
7W C-7 AC incandescent
lamps
> Lead Calcium battery
(Self-Powered)
> Ceiling, wall, or end
mounting
13" [330mm]

2 3/4" [70mm]

> Universal J-box mounting
pattern
> Universal exits can be field
configured as single face or
double face includes both
red and green lenses
> Components are of snap-fit
construction to facilitate
rapid installation
> Reinforcing ribs throughout
to provide maximum strength
> Snap-out chevron directional
indicators
> Snap-fit canopy with
mounting screws included
with all exits
> UL damp location listed
> UL 924, Life Safety NFPA 101,
NEC/OSHA, Most State and
Local Codes

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: INCX20RGWH

INCX
Family
INCX=
Incandescent Exit
Series
2=AC Only with 130V,
7W C-7 AC
Incandescent Lamps
3=Self-Powered with
130V, 7W, C-7 AC
Incandescent Lamps

Housing Finishes
WH=White

Accessories (Order Separately)
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield,
Weather Resistant
WG10=Wire Guard for Surface Mount
Applications
WGS11=Wire Guard for Ceiling or End
Mount Applications

Energy Data

INCX30RGWH

COOPER LIGHTING

Letter Colors
RG=Red/Green

Face Options
0=Universal

INCX20RGWH

58

Battery
Blank=Lead
Calcium
(INCX30)

Input Power:
120V
12W
Input Power:
120V
277V
16.3W
14.2W

Input Current(Max.):
120V
.10A
Input Current(Max.):
120V
277V
.14A
.05A

Power Factor:
120V 277V
>.97
>.97

T.H.D.:
120V 277V
<10% <14%

DIMENSIONS

DESCRIPTION

Commercial

The SLX Series Steel LED Exit
is the ideal exit for general
purpose applications. With an
extensive range of field
installed accessories, choice of
faces, and the variety of
possible mounting
configurations, this exit can be
tailored to fit almost any
application. The Sure-Lites
Steel LED Exit offers low
energy consumption and
requires little maintenance due
to highly efficient, long life LED
lamps. Durable steel construction, attractive styling and high
efficiency illumination make
this series compatible in
commercial, institutional and
multi-housing applications.

EXIT SIGNS >

SURE-LITES®

SLX SERIES
Steel
AC Only
S e l f - Powe re d
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N

> Dual-voltage Input 120/277
or 120/347 VAC, 60Hz

SAMPLE NUMBER: SLX70RWH

> 20 gauge steel housing
> Long life LED lamps
provide uniform diffused
illumination

SLX
Letter
Colors
R=Red
G=Green

Family
SLX=Steel LED
Series
6=AC Only with LED Lamps
7=Self-Powered with LED
Lamps
Face Options
0=Universal
Battery
Blank=No Battery (SLX6)
Blank=Nickel Cadmium
Battery (SLX7)

Housing
Finishes
WH=White
BK=Black

Accessories (Order Separately)
Pendant Kit
PK18BK=Black, 18" Long
PK18WH=White, 18" Long

Option
SD=Self-Diagnostic
(Red LED,
White Housing
Only) (SLX7
Only)

Hang-True Pendant Kit
PK18HTWH=White
PK18HTBK=Black

Factory Options
90=Fire Alarm Interface
(available with SD option
only.) (SLX7 Only.)

> Universal: Both single or
double face; ceiling, wall
or end mounting

Other Accessories
WG10=Surface, Wire Guard
WGS11=Ceiling, End Wire Guard
VS1=Polycarbonate Vandal Shield
VS1WP=Polycarbonate Vandal Shield
Weather Resistant
PLC2CU=FTBR (2C) Conversion Canopy
(SLX6 Only)

Voltage
Blank=120/277V
47=120/347V
Exit Face 1
Blank=Exit Face, NOM
Certified
SAL=Salida Face, NOM
Certified (Not UL Listed)

E n e rgy Da t a — S e l f - Powe re d E x i t s

Sealed Nickel Cadmium Battery
Input Power:
Input Current (Max.):

Power Factor:

T.H.D.:

120V 277V 347V

120V 277V 347V
LED Exits

120V 277V 347V

120V 277V 347V

LED Exits -Red Letters

3.8W 3.9W 4.2W

035A .016A .014A

>.90

> .90 > .88

<21% <21% <22%

LED Exits -Green Letters

6.3W 6.5W 6.1W

.08A .04A

>.71

>.71

<36% <39% <39%

.03A

> .77

Energy Data — AC Only Exits

Input Power:

LED Exits -Red Letters
LED Exits - Green Letters

1For

Input Current (Max.):

Power Factor:

> Knockouts for chevron
directional indicators
> Universal styles offer
complete installation
flexibility with canopy,
backplate, and two
stencil faces
> Self-powered Exit features
line-latching, solid-state
voltage limited charger,
solid-state switching,
brownout circuit, lowvoltage disconnect, test
switch, LED indicator light
> Energy Star Qualified
(SLX60RWH, SLX70RWH,
SLX70RWHSD)
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes,
CSA Certified, NOM
Certified

T.H.D.:

120V 277V 347V

120V 277V 347V
LED Exits

120V 277V 347V

120V 277V 347V

3.3W 3.4W 3.8W
5.0W 5.1W 5.1W

.03A .01A
.07A .03A

> .90 > .90 > .80
> .62 > .62 > .72

< 22% < 22% < 41%
< 39% < 42% < 40%

.01A
.02A

> Premium Nickel Cadmium
battery (Self-Powered)

use in Mexico, add the prefix MEX to the catalog number in addition to the face description (e.g.: MEX-SLX70RWHSAL).

COOPER LIGHTING

59

DIMENSIONS

DESCRIPTION

The Sure-Lites Standard Steel Exit Series is
the ideal exit for general purpose applications. With an extensive range of field
installed accessories, choice of faces, and
the variety of possible mounting configurations, this basic exit can be tailored to fit
almost any application.

EXIT SIGNS >

Commercial

SURE-LITES®

R/G/OF/PLX
SERIES
Steel
AC Only
EXIT LIGHTING

> 120 VAC input voltage

S T E E L E X I T S – A C O N LY I N C A N D E S C E N T
Type

Mounting

Stencil Face, White Finish
Red
Green
Letters
Letters

Stencil Face, Black Finish
Red
Green
Letters
Letters

Stencil Face, Black/Silver Finish
Red
Green
Letters
Letters

Universal1
Universal Open Face 2

Wall/Ceiling/End
Wall/Ceiling/End

R2CX3
G2CX4
OF2CX (specify lens)

R2CXB3
G2CXB3
OF2CXB (specify lens)

R2CXBS3
G2CXBS4
OF2CXBS (specify lens)

> 20 gauge steel housing
> LED, Fluorescent, or
Incandescent lamping
> LED: long life LED lamp
modules
> Fluorescent: two 5W
F5TT lamps
> Incandescent: two 20W
T6 1/2 intermediate base
lamps
> Universal: both single and
double face; ceiling, wall
or end mounting

S T E E L E X I T S – A C O N LY F L U O R E S C E N T
Type

Mounting

Stencil Face, White Finish
Red
Green
Letters
Letters

Stencil Face, Black Finish
Red
Green
Letters
Letters

Stencil Face, Black/Silver Finish
Red
Green
Letters
Letters

Universal1
Universal Open Face2

Wall/Ceiling/End
Wall/Ceiling/End

PLX5200RP3
PLX5200GP
PLX5200OP (specify lens)

PLX5200RB3
PLX5200GB
PLX5200OB (specify lens)

PLX5200RBS3 PLX5200GBS
PLX5200OBS (specify lens)

S T E E L E X I T S – A C O N LY L E D (6)
Type

Universal1

Mounting

Wall/Ceiling/End

Stencil Face
White Finish,
Red Letters
120 VAC 277 VAC

Stencil FaceStencil Face
White Finish,
Green Letters
120 VAC
277 VAC

Stencil Face
Black Finish,
Red Letters
120 VAC
277 VAC

Black Finish,
Green Letters
120 VAC
277 VAC

R2CXLED

G2CXLED

R2CXBLED

G2CXBLED

R2277CXLED

G2277CXLED

R2277CXBLED

G2277CXBLED

O R D E R I N G I N F O R M AT I O N

> Knockouts for chevron
directional indicators
> Universal styles offer
installation flexibility with
canopy, backplate, and two
stencil faces

SAMPLE NUMBER: CX395C

Model Number
See chart

> Louvered downlight
> Suitable for floor proximity
installation
> UL FTBR Listed

Factory Options
95=AC Only Fire Alarm
Interface
(Incandescent. Add
option number after
series: e.g. OF295CX)
2C=Two Circuit Operation
(Incandescent &
Fluorescent. Add to
end of catalog number: e.g.
PLX5200OP2C)

> Damp Location Listed
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

Accessories (Order Separately)
Canopy Kit
CAN571=White
CAN578=Black

Tamperproof Accessories
TPK1CP=Tamperproof Screws
0590A638SP=Screwdriver bit for
TPK-1-CP Screws

Power Pack
EPX5000B=Black
EPX5000P=White

Wire Guard
WG10=Surface Wire Guard
WGS11=Ceiling, End Wire Guard

277V Conversion Canopy
PLC277B=Black
PLC277P=White
Pendant Kit
PK18BK=Black, 18” Long
PK18WH=White, 18" Long

VS1=Polycarbonate Vandal Shield

Energy Data

Incandescent Exits
Fluorescent Exits 5W Lamps
Fluorescent Exits 7W Lamps

60

AC-Only-Incandescent Exits
Input Power:
Input Current (Max.): Power Factor:
120V
277V
120V
277V
120V 277V
40W
42W
.33A
.16A
AC-Only-Compact Fluorescent Exits
17W
22W
.32A
.18A
>.43 >.44
17W
22W
.28A
.16A
>.53 >.50

T.H.D.:
120V 277V

<8% <9%
<9% <10%

1Universal Face Exits include two stencil faces, canopy and backplate. 2For Open Face Exits, specify lens desired: 004346SP-red letters, white
background; 004347SP - green letters, white background; 004340SP -white letters, red background; 004341SP-white letters, green background;
Special wording, consult your Cooper Lighting Representative. Order Separately. 3Standard UL FTBR Listed. 4Standard FWBO; UL FTBR
Listed with “2C” Option.

COOPER LIGHTING

DESCRIPTION

DIMENSIONS

UN/UNH/PLX
SERIES

STEEL EXITS – SELF-POWERED INCANDESCENT
Type

Mounting

Universal 1
Universal Open Face 2

Wall/Ceiling/End UN1SRW
UN1SGW
Wall/Ceiling/End UN1OFW (specify lens)

Commercial

The Sure-Lites Self-powered Standard
Steel Exit Series is the ideal exit for
general purpose applications. With an
extensive range of field installed
accessories, choice of faces and a
variety of mounting configurations, this
basic exit can be tailored to fit almost
any application.

EXIT SIGNS >

SURE-LITES®

Stencil Face, White Finish
Stencil Face, Black Finish
Stencil Face, Black/Silver Finish
Red Letters
Green Letters Red Letters
Green Letters Red Letters
Green Letters
UN1SRB
UN1SGB
UN1OFB (specify lens)

UN1SRBS
UN1SGBS
UN1OFBS (specify lens)

Steel
S e l f - Powe re d

ST E E L E X I T S – S E L F- P OW E R E D I N C A N D E S C E N T W I T H A D D I T I O N A L O U T P U T TO P OW E R R E M OT E S
Universal 1
Universal Open Face 2

Wall/Ceiling/End UNH1SRW
UNH1SGW
Wall/Ceiling/End UNH1OFW (specify lens)

UNH1SRB
UNH1SGB
UNH1OFB (specify lens)

UNH1SRBS
UNH1SGBS
UNH1OFBS (specify lens)

PLX6200RB
PLX6200GB
PLX6200OB (specify lens)

PLX6200RBS
PLX6200GBS
PLX6200OBS (specify lens)

STEEL EXITS – SELF-POWERED FLUORESCENT
Universal 1
Universal Open Face 2

Wall/Ceiling/End PLX6200RP
PLX6200GP
Wall/Ceiling/End PLX6200OP (specify lens)

ST E E L E X I T S – S E L F P OW E R E D F L U O R E S C E N T W I T H A D D I T I O N A L O U T P U T TO P OW E R R E M OT E S
Universal 1
Universal Open Face 2

Wall/Ceiling/End
Wall/Ceiling/End

PLX7200RP
PLX7200GP
PLX7200OP (specify lens)

PLX7200RB
PLX7200GB
PLX7200OB (specify lens)

PLX7200RBS
PLX7200GBS
PLX7200OBS (specify lens)

STEEL EXITS – SELF-POWERED LED
Type

Mounting

Stencil Face, White
Finish, Red Letters

Stencil Face, White
Finish, Green Letters

Stencil Face, Black
Finish, Red Letters

Stencil Face, Black
Finish, Green Letters

Universal 1

Wall/Ceiling/End

UN1SRWLED

UN1SGWLED

UN1SRBLED

UN1SGBLED

EXIT LIGHTING

> Dual-voltage input
120/277VAC, 60Hz
> 20 gauge steel housing
> LED, Fluorescent, or
Incandescent lamping
> AC LED: long life LED lamp
modules-DC: two 6V, 3.6W
DC lamps
> AC fluorescent: two 5W
F5TT lamps-DC: three 6V,
3.6W DC lamps

ST E E L E X I T S – S E L F P OW E R E D L E D W I T H A D D I T I O N A L O U T P U T TO P OW E R R E M OT E S
Universal 1

Wall/Ceiling/End

UNH1SRWLED

UNH1SGWBLED

UNH1SRBLED

UNH1SGBLEDL

WAT TA G E R AT I N G S
UN
UNH
PLX-6200
PLX-7200

Lead
Lead
Lead
Lead

Calcium=10.8W for 1 1/2 hrs., 7.2W for 2 hrs.
Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs.
Calcium = 10.8W for 1 1/2 hrs.
Calcium = 27W for 1 1/2 hrs.; 24W for 2 hrs.

Nickel
Nickel
Nickel
Nickel

Cadmium=15W for 1 1/2 hrs; 12W for 2 hrs.
Cadmium=24W for 1 1/2 hrs.; 18W for 2 hrs.
Cadmium = 15W for 1 1/2 hrs.; 12W for 2 hrs.
Cadmium = 24W for 1 1/2 hrs.; 18W for 2 hrs.

O R D E R I N G I N F O R M AT I O N

Factory Options
(For ordering with incandescent, add option numbers in
order listed after series; e.g. UNH170200FW. For ordering
with fluorescent, replace “00” with option numbers in
order listed; e.g. PLX6230RP. For ordering with LED, add
option numbers in order listed after series;
e.g.UN1702090SRWLED)
70=Nickel Cadmium Batteries
20=DC Flasher
30=DC Flasher/Buzzer
90=DC Fire Alarm Interface (Incandescent and LED Only)
SD=Self-Diagnostics (Add to end of catalog number:
e.g. UN130SRWSD)

> Lead Calcium or Premium
Nickel Cadmium battery
> Universal: both single and
double face; ceiling, wall
and end mounting

SAMPLE NUMBER: UNH170SRWSD

Model
Number
See chart

> AC incandescent: two 20W
T6 1/2 intermediate base
lamps-DC: two 6V, 3.6W DC
Lamps

Accessories
(Order Separately)
FL1=Flasher Kit
BZ1=Buzzer Kit
Pendant Kit:
PK18BK=Black, 18” long
PK18WH=White, 18” long
Canopy Kit:
CAN571=White
CAN578=Black

Tamperproof Accessories:
TPK1CP=Tamperproof
Screws
0590A638SP=Screwdriver
bit for TPK1CP Screws
Wire Guard
WG10=Surface Wire Guard
WGS11=Ceiling, End Wire
Guard
VS2=Polycarbonate Vandal
Shield
VS2WP=Polycarbonate
Vandal Shield Weatherproof

Energy Data
Charged Mode (Fully Discharged Battery) Sealed Lead Calcium Battery
Input Power:
Input Current (Max.): Power Factor:
T.H.D.:
120V
277V
120V
277V
120V
277V
120V
277V
Incandescent Exits 20W Lamps
53W
51W
.45A
.19A
>.99
>.98
<9%
<10%
Fluorescent Exits 5W lamps
33W
33W
.44A
.18A
>.62
>.65
<10% <8%
Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by approximately 7.5 Watts
in the standby operating mode
Sealed Lead Calcium Battery
Incandescent Exits 20W Lamps
47W
44W
.40A
.16A
>.98
>.98
<8%
<8%
Fluorescent Exits 5W lamps
26W
26W
.41A
.16A
>.52
>.57
<11% <10%
Charged Mode (Fully Discharged Battery) Sealed Lead Calcium Battery
LED Exits Red Letters (UN)
10.4W
10.8W
.10A
.04A
>.89
>.88
<45% <48%
LED Exits Red Letters (UNH)
12.6W
13.2W
.10A
.05A
>.91
>.91
<39% <42%
LED Exits Green Letters (UN)
11.9W
12.3W
.10A
.05A
>.96
>.94
<29% <33%
LED Exits Green Letters (UNH)
15.8W
15.4W
.14A
.06A
>.97
>.96
<25% <29%
Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 7.5 Watts
in the standby operating mode
Sealed Nickel Cadmium Battery
LED Exits Red Letters (UN)
4.8W
4.7W
.05A
.02A
>.76
>.73
<63% <68%
LED Exits Red Letters (UNH)
9.1W
9.1W
.08A
.04A
>.90
>.89
<36% <40%
LED Exits Green Letters (UN)
6.1W
6.0W
.06A
.03A
>.88
>.85
<47% <52%
LED Exits Green Letters (UNH)
10.3W
10.3W
.09A
.04A
>.96
>.95
<24% <29%

> Knockouts for chevron
directional indicators
> Universal styles offer
complete installation
flexibility with canopy,
backplate, and 2 stencil
faces
> Louvered downlight
> Suitable for floor proximity
installation
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/ power
indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

1Universal Face Exits include two stencil faces, canopy and backplate. 2For Open Face Exits, specify lens desired: 004346SP-red letters, white background;

004347SP - green letters, white background; 004340SP - white letters, red background; 004341SP-white letters, green background; Special wording, consult your
Cooper Lighting Representative. Order Separately.

COOPER LIGHTING

61

DIMENSIONS

DESCRIPTION

The Sure-Lites UNH/PLX Series Steel
Exits combine a self powered exit
sign with an emergency light. With
an extensive range of field installed
accessories, choice of faces and the
variety of mounting configurations,
this exit can be tailored to fit almost
any application.

EXIT SIGNS >

Commercial

SURE-LITES®

UNH/PLX SERIES
Steel
S e l f - Powe re d w i t h
Emergency Heads

INCANDESCENT EXITS
Type

Mounting

Stencil Face, White Finish
Red Letters
Green Letters

Stencil Face, Black Finish
Red Letters
Green Letters

Stencil Face, Blk/Silver Finish
Red Letters
Green Letters

EXIT LIGHTING

Universal 1

Wall/Ceiling/End
Wall/Ceiling/End

UNH1SRWDH UNH1SGWDH
UNH1OFWDH (specify lens)

UNH1SRBDH
UNH1SGBDH
UNH1OFBDH (specify lens)

UNH1SRBSDH
UNH1SGBSDH
UNH1OFBSDH (specify lens)

PLX7202RB
PLX7202GB
PLX7202OB (specify lens)

PLX7202RBS
PLX7202GBS
PLX7202OBS (specify lens)

Universal Open Face 2

> Dual-voltage input
120/277VAC, 60Hz

FLUORESCENT EXITS

> 20 gauge steel housing

Universal1
Universal Open Face 2

> LED, Fluorescent, or
Incandescent Lamping

LED EXITS

> AC LED: long-life LED
lamp modules;
DC: two 6V, 3.6W DC lamps

Wall/Ceiling/End
Wall/Ceiling/End

PLX7202RP
PLX7202GP
PLX7202OP (specify lens)

Type

Mounting

Stencil Face, White
Finish, Red Letters

Stencil Face, White
Finish, Green Letters

Stencil Face, Black
Finish, Red Letters

Stencil Face, Black
Finish, Green Letters

Universal

Wall/Ceiling/End

UNH1SRWDHL

UNH1SGWDHL

UNH1SRWBDHL

UNH1SGWBDHL

WAT TA G E R AT I N G S

> AC fluorescent: (2) 5W F5TT
lamps - DC: three 6V, 3.6W
DC lamps
> AC incandescent: (2) 20W
T6 1/2 intermediate base
lamps - DC: two 6V, 3.6W
DC lamps
> Two thermoplastic heads
with matching finish
> Heads: 6V, 9W wedge base
style lamps (7.2W nickel
cadmium exits)

PLX-7202
UNH

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: UNH1SRWDHSD

Model Number
See chart

> Lead Calcium or Premium
Nickel Cadmium batteries
> Universal: both single and
double face; ceiling, wall
and end mounting
> Knockouts for chevron
directional indicators
> Universal styles include
canopy, backplate, and two
stencil faces
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/
short-circuit protection, test
switch/power indicator light
> UL 924 Listed, life safety
NFPA 101, NEC/OSHA,
most state and local codes

COOPER LIGHTING

Factory Options
(For ordering with incandescent and LED, add
option numbers in order listed after series;
e.g. UNH17090SRBDHL. For ordering with fluorescent
add option numbers in order listed after “PLX7202”;
e.g. PLX720270GP.)
70=Nickel Cadmium Batteries
20=DC Flasher
30=DC Flasher/Buzzer
90=DC Fire Alarm Interface (Incandescent & LED)
SD=Self-Diagnostics (Add to end of catalog number;
e.g. PLX7202RPSD)

Accessories
(Order Separately)
FL1=Flasher Kit
BZ1=Buzzer Kit
Pendant Kit
PK18-BK=Black, 18" long
PK18-WH=White, 18" long
Canopy Kit
CAN571=White
CAN578=Black

Tamperproof Accessories
TPK1CP=Tamperproof
Screws
0590A638SP=Screwdriver
bit for TPK1CP Screws
WG2=Wire Guard
VS2=Polycarbonate Vandal
Shield
VS2WP=Polycarbonate
Vandal Shield Weatherproof

Energy Data

Charge Mode (Fully Discharged Battery) Lead Calcium Battery
Input Power:
Input Current (Max.):
Power Factor:
T.H.D.:
120V
277V
120V
277V
120V 277V
120V 277V
Charged Mode (Fully Discharged Battery) Lead Calcium Battery
Incandescent Exits 20W Lamps
53W
51W
.45A
.19A
>.99 >.98
<9% 10%
Fluorescent Exits 5W lamps
33W
33W
.44A
.18A
>.62 >.65
<10% <10%
LED Exits Red
12.6W
13.2W
.11A
.05A
>.91 >.91
<39% <42%
LED Exits Green
15.8W
15.4W
.14A
.06A
>.97 >.96
<25% <29%
Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by approximately 7.5 Watts in the standby operating mode
Sealed Lead Calcium Battery
Incandescent Exits 20W Lamps
47W
44W
.40A
.16A
>.98 >.98
<8% <8%
Fluorescent Exits 5W lamps
26W
26W
.41A
.16A
>.52 >.57
<11% <10%
LED Exits Red
9.1W
9.1W
.08A
.04A
>.90 >.89
<36% <40%
LED Exits Green
10.3W
10.3W
.09A
.04A
>.96 >.95
<24% <29%

1Universal

62

Lead Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs. Nickel Cadmium=24W for 1 1/2 hrs.; 18W for 2 hrs.
Lead Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs. Nickel Cadmium=24W for 1 1/2 hrs.; 18W for 2 hrs.

Face Exits include two stencil faces, canopy and backplate. 2For Open Face Exits, specify lens desired: 004346SP-red letters, white
background; 004347SP - green letters, white background; 004340SP - white letters, red background; 004341SP-white letters, green background;
Special wording , consult your Cooper Lighting Representative. Order Separately.

DIMENSIONS

DESCRIPTION

The All Pro Series emergency
light (AP2SQ) is the ideal choice
when an affordable thermoplastic unit is required for general
purpose applications. Its styling
and designer finish enables it to
blend with any decor. The
housing and mounting plate
employ snap-fit construction to
further improve the installation
time. Both lighting heads are
fully adjustable, insuring that
light can be put where it is
needed.

ALL PRO EMERGENCY

SURE-LITES®

AP2SQ SERIES
All Pro
EMERGENCY LIGHTING

> Dual-voltage input

120/277VAC, 60Hz
> High impact white

thermoplastic housing
> Square, two head design
> Fully adjustable lamping
> Sealed Lead Calcium

battery
> Test Switch/Power

Indicator Light
E L E C T R I C A L R AT I N G S
Model
AP2SQ

> Quick connect AC power

Rated Wattage to 87 1/2% of Rated D.C. Voltage
DC Voltage
1 1/2 Hours
2 Hours
6
10.8
7.2

Lamp Information
Type
Wattage
Incandescent
5.4

Number
29-121

connector facilitates
installation
> Suitable for wall or ceiling

mount applications
> ETL Indoor Damp Location

O R D E R I N G I N F O R M AT I O N

Listed

SAMPLE NUMBER: AP2SQ

> UL 924 Listed, Life Safety

AP2SQ
Model Number
AP2SQ

Housing Finish
Blank=White

Accessories
(Order Separately)
WG-1= Wire Guard
VS1= Polycarbonate Vandal Shield
VS1WP= Polycarbonate Vandal Shield
Weather Resistant

NFPA 101, CSA Certified,
NEC/OSHA, most state
and local codes

COOPER LIGHTING

63

ALL PRO EMERGENCY

SURE-LITES®
DIMENSIONS

DESCRIPTION

AP SERIES

The All Pro Series exit (AP60/70) is
the most economical LED exit for
general purpose applications. The
durable, injection molded, thermoplastic material resists discoloration
due to UV radiation and the energy
efficient, low maintenance LED's
provide bright illumination.
All AP series exits offer universal
configurations (single and double
face) and have universal mounting
capability (ceiling, wall, end).

All Pro
AC Only
S e l f - Powe re d
EXIT LIGHTING

> Dual-voltage input
120/277VAC, 60Hz
> High impact white
thermoplastic housing
> AC LED: Long life LED
lamps provide uniform
diffused illumination

O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : A P- 7 0 R

AP

-

> DC: LED DC lamps
(Brighter in emergency
mode, AP70)

Family
AP=All Pro Exit

> Nickel Cadmium battery
(AP70)

Series
6=AC Only LED
7=Self-powered
with LED

> Ceiling, wall, or end
mounting
> Field selectable chevrons
> Universal exits can be
field configured as single
face or double face

0

Letter
Colors
R=Red
G=Green

Housing
Finish
Blank=White
BK=Black

Voltage
Blank=
120/277 VAC

Face Options
0=Universal
Battery
Blank=Nickel Cadmium (AP70)

> Test Switch/Power
Indicator Light (AP70)
> ETL Damp Location Listed
> UL 924 Listed, UL FTBR
Listed (2C Only), Life
Safety NFPA 101,
NEC/OSHA, most state and
local codes

64

COOPER LIGHTING

E N E R G Y D ATA

E N E R G Y D ATA

AC Only
LED Exits - Red
Input Power:
120V = 2.0W
277V = 2.1W

LED Exits - Green
Input Power:
120V = 2.2W
277V = 2.1W

Sealed Nickel Cadmium Battery
LED Exits - Red
LED Exits - Green
Input Power:
Input Power:
120V = 3.0W
120V = 3.0W
277V = 3.0W
277V = 3.0W

Input Current
(Max.):
120V = .02A
277V = .01A

Input Current
(Max.):
120V = .02A
277V = .01A

Input Current
(Max.):
120V = .03A
277V = .02A

Input Current
(Max.):
120V = .03A
277V = .02A

Power Factor:
120V = > .89
277V = > .88

Power Factor:
120V = > .88
277V = > .87

Power Factor:
120V = >.91
277V = >.90

Power Factor:
120V = > .92
277V = > .90

T.H.D.:
120V = < 25%
277V = < 31%

T.H.D.:
120V = < 26%
277V = < 32%

T.H.D.:
120V = <29%
277V = <32%

T.H.D.:
120V = < 30%
277V = < 35%

2C=Two
Circuit
(AP60G Only)

Accessories
VS=Choose polycarbonate vandal
shield desired
from accessories
sheet
WG=Choose size of
wire guard
desired from
accessories sheet

DIMENSIONS

DESCRIPTION

The All Pro Series exit with heads
(combo) is the most economical LED
exit available in the market for general purpose applications. The
durable, injection molded, thermoplastic material resists discoloration
due to UV radiation and the energy
efficient, low maintenance LEDs provide bright illumination. The AP
Series combos are available in universal configurations (single and
double face) and have universal
mounting capability (ceiling, wall,
end).

ALL PRO EMERGENCY

SURE-LITES®

AP SERIES EXIT
WITH HEADS
All Pro
S e l f - Powe re d
with Double Heads
(Remote Capacity)
EXIT LIGHTING

> Dual Voltage 120/277 VAC,

60 Hz

O R D E R I N G I N F O R M AT I O N

> High impact, white,

SAMPLE NUMBER: AP70RWHDH

AP

7

0

WH

Family
AP=All Pro
Emergency
Exit/
Emergency

Letter Colors
R=Red
DG=Premium
Deep Green

H=High Power (Remote
Capability, Red Only)
Blank = No Remote Capacity

Housing Finishes
WH=White

Series
7=Self-powered with LED

Voltage
Blank=120/277 VAC

Face Options
0=Universal
Battery
Blank=Lead Calcium

thermoplastic housing

DH
Heads
DH=Double
Heads

Options
SQ=Square Heads
(5.4W Lamp)

> AC LED: Long life LED
Accessories
WG=Wire Guard
(Choose size of
wire guard from
accessories sheet)
VS=Choose polycarbonate vandal
shield desired
from accessories
sheet

lamps provide uniform
diffused illumination
> DC: LED DC lamps

(Brighter in emergency
mode)
> Heads DC: 6V, 5.4W

incandescent wedge
base lamps
> Lead Calcium battery

(11W remote capacity:
APH only)
> Universal exits can be

field configured as single
face or double face
> Exit can be ceiling, wall or

end mounting
WAT TA G E R AT I N G S

> Field selectable chevrons

APH

> UL Damp Location Listed

with Double heads (DH) has remote capacity of 11 watts for 1 1/2 hrs.

> UL 924 Listed, Life Safety
E N E R G Y D ATA
Standby Mode (Fully charged Battery):
Sealed Lead Calcium Battery
LED Exits LED Exits - Red
Input Power:
Premium Deep Green
120V = 4.9W
Input Power:
277V = 4.7W
120V = 3.1W
277V = 2.9W
Input Current (Max.):
Input Current (Max.):
120V = .07A
277V = .03A
120V = .06A
Power Factor:
277V = .02A
Power Factor:
120V = >.59
277V = >.64
120V = >.41
277V = >.44
T.H.D.:
120V = <45%
T.H.D.:
277V = <44%
120V = <49%
277V = <53%

NFPA 101, CSA Certified,
NEC/OSHA, most state and
local codes

Charge Mode (Discharged Battery):
Sealed Lead Calcium Battery
Input Power consumption is increased by approximately
2.7 watts in the charge operating mode for red units and
3.4 watts for green units

COOPER LIGHTING

65

Emergency Lights

INDUSTRIAL & HAZARDOUS LOCATION >

SURE-LITES®
DESCRIPTION

DIMENSIONS

The Sure-Lites UEL NEMA 4X
Emergency Light is designed for
those emergency lighting applications where ruggedness and
dependability are a must.
Designed for the most severe environments, the UEL Emergency Light
will provide maximum performance
against rain, moisture, cold, corrosives and dust.

UEL SERIES
U LT I M AT E E M E R G E N C Y
LIGHT
EMERGENCY LIGHTING

> NEMA 4X, UL50 Listed
> Dual-voltage input
120/277VAC, 60Hz,
Isolation Transformer

15 1/4”
[389mm]

6 3/16”
[157mm]

The UEL’s standard features include
die cast housing, nickel cadmium
battery, self-diagnostics, photocell
LASER test and MR16 lamps. In
addition, the injection molded,
polycarbonate shield provides
protection against moisture, rain,
and vandalism. (4) Torx head tamperproof screws with center-pin
reject provide additional vandalproof security.
The unique design and features
make the UEL Emergency Light
compatible in food processing
facilities, outdoor parking garages,
walk-in freezers and other indoor/
outdoor severe environments.

6 11/16”
[169mm]

Laser Test

Self-Diagnostics

The self-diagnostic unit will automatically
perform the tests required by the NFPA 101 Life
Safety Code. The system indicates the status of
the unit at all times using an LED indicator that
is located near the test switch.

> Die cast aluminum housing
with powder coat finish
> UV stable, glass-clear
polycarbonate, vandal
resistant shield (.150” thick)
with Torx head tamperproof
screws, stainless steel

Verify proper operation of the
transfer circuit and emergency
lamps with a convenient laser
pointer (sold as an accessory).

> (2) Adjustable 12W, MR16
lamps

SPLASH ZONE

> Nickel Cadmium Battery
> Fully recharged in 24 hours
> Vandal Proof
> Watchguard EMS
Self-Diagnostic System

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage

Lamp Information

Model

DC Voltage

1 1/2 Hours

Type

Wattage

Number

Spacing1

UEL1SD

12

24

MR16

12

29-141

50.0'

> Photocell Test Switch
(requires accessory LASER
for activation)
> UL 924 Outdoor Wet
Location Listed (suitable for
wet and damp locations)
> T1 Haz Lamp Rating
> NSF, National Sanitation
Foundation/Splash Zone
(for Food Processing)

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: UEL1SD

Family
UEL1=Nema 4X
Emergency
Light

Housing
Finishes
Blank=Silver
BK=Black
WH=White

SD=Self Diagnostics
(Standard)

> Patent Pending

COOPER LIGHTING

LASER=Key Chain, Red Laser Pointer
(activation tested at 30 feet)

V=Voltmeter
TDM=Time Delay Monitor

UXPKA=Pendant Kit Adapter (fitting adapts
to 1/2" NPT threaded pendant)
VRSD=#8 Centerpin Torx Screwdriver

Energy Data

Model No.
UEL1SD

1The

66

Accessories (order separately)

A=Ammeter

HAZ=Hazardous Locations
(Class I, Division 2,
Groups A, B, C, D)

> IP66, Ingress Protection
from IEC (International
Electrical Commission)
> Cleanroom Class 10,000

Options

Input Current (Max.):
120V
277V
.09A
.03A

"Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 feet ceiling with a 6 feet wide walkway and 3 feet path of egress.
The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees.
Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not
as guarantee of any code compliance.

DESCRIPTION

DIMENSIONS

The NCB Series is a premium
grade emergency lighting system with all metal construction
that combines functional
styling and power performance
capability. These units contain
serviceable nickel cadmium
batteries and feature advanced
solid-state circuitry.

NCB SERIES
S e r v i c e a b l e We t C e l l
Nickel Cadmium Battery
High-Capacity
E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage

Lamp Information

Model

DC Voltage

1 1/2 Hours

2 Hours

3 Hours

4 Hours

Type

Wattage

Number

NCB45 1
NCB90 1
NCB110 1
NCB1290 1
NCB12180 1
NCB12225 1

6
6
6
12
12
12

45
90
110
90
180
225

33
67
82
67
135
168

22
45
55
45
90
112

16
33
41
33
67
84

Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent

9
9
9
9
9
9

29-84
29-84
29-84
29-86
29-86
29-86

> Dual-voltage input

120/277VAC, 60Hz
> 18 gauge die-formed steel

housing and cover (white)

Emergency Lights

EMERGENCY LIGHTING

INDUSTRIAL & HAZARDOUS LOCATION >

SURE-LITES®

> Two fully adjustable,

high-impact thermoplastic
heads standard (white)
O R D E R I N G I N F O R M AT I O N

> Serviceable wet cell nickel

cadmium battery

SAMPLE NUMBER: NCB45VTDM

> Line-latching, Solid-State
Model Number
NCB45
NCB90
NCB110
NCB1290
NCB12180
NCB12225

Options (Add as Suffix)
MH=Metal Heads
A=Ammeter
TDM=Time Delay Monitor
V=Voltmeter
Alternate Lamps 2
Other Options 2

Accessories (Order separately)
3MSWH=Mounting Shelf (not applicable for NCB12225)
(White Finish)
3BRWH=Mounting Brackets (3-White Finish)
WG3=Wire Guard (not applicable for NCB12225)
CSK120=Cord Set (120 VAC)
CSK277=Cord Set (277 VAC)
VS2=Polycarbonate Vandal Shield
VS2WP=Polycarbonate Vandal Shield - Weatherproof

switching, low-voltage
disconnect, brownout
circuit, overload/shortcircuit protection, test
switch/power indicator
light
> Knockout, conduit or cord

set
> Keyhole mounting slots
> UL 924 Listed, Life Safety

NFPA 101, Listed
NEC/OSHA, most state
and local codes

Energy Data

Model No.
NCB45
NCB90
NCB110
NCB1290
NCB12180
NCB12225

Input Current (Max.):
120V
277V
.45A
.17A
.50A
.20A
.81A
.34A
.84A
.37A
.72A
.30A
1.28A
.55A

Note: 0, 1, 2, 3 and 4 Heads also available. Specify after catalog number (i.e., NCB12180408)
1Battery

shipped separate but automatically included with unit
NCB45 - Qty. 1
02625 battery
NCB1290
NCB90 - Qty. 1
02626 battery
NCB12180
NCB110 - Qty. 2
026129 battery
NCB12225
2Consult your Cooper Lighting Representative.

- Qty. 2
- Qty. 2
- Qty. 2

02625 battery
02626 battery
026129 battery

COOPER LIGHTING

67

Emergency Lights

INDUSTRIAL & HAZARDOUS LOCATION >

SURE-LITES®
DIMENSIONS

DESCRIPTION

The ideal unit for wet environments where an emergency
lighting unit will be exposed to
water spray, penetrating steam,
or dampness. The UMB Series is
best suited for use in areas like
waste water treatment plants,
food processing facilities and
most industrial applications.

UMB SERIES
We t L o c a t i o n
EMERGENCY LIGHTING

> NEMA 4X
> Dual-voltage input
120/277VAC, 60Hz
> Grey fiberglass housing
> Two top mounted,
fully adjustable, grey,
high-impact thermoplastic
heads standard

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model
UMB1
UMB6
UMB7
UMB8
UMB9
UMB14
UMB15
UMB16
UMB17

DC Voltage
6
6
6
12
12
6
6
12
12

Battery
LC
LC
LC
LC
LC
NC
NC
NC
NC

1 1/2 Hours
18
27
54
36
54
15
24
30
48

2 Hours
15
24
48
30
48
12
18
24
36

Lamp Information
3 Hours
10
18
36
20
36
8
12
16
24

4 Hours
8
14
28
16
28
6
10
12
20

> Glare-free lens with PAR36
sealed beam lamps
> Watertight and corrosion
resistant

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: UMB6TH

> UL Wet location listed
(32˚F or 0˚C and above)
> Gasketed, internally
hinged front cover
> Remote capability
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes

68

COOPER LIGHTING

Model Number
UMB1
UMB6
UMB7
UMB8
UMB9
UMB14
UMB15
UMB16
UMB17

Options (add as Suffix)
TDM=Time Delay Monitor
TH=Thermal Heater
Alternate Lamps 1
Other Options 1

Energy Data

Model No.
UMB1, UMB6, UMB7
UMB8, UMB9
UMB14
UMB15
UMB16
UMB17

1Consult

Input Current (Max.):
120V
277V
.12A
.05A
.30A
.13A
.06A
.03A
.07A
.04A
.13A
.06A
.15A
.07A

your Cooper Lighting Representative.

Accessories
(Order separately)
WG7=Wire Guard
VS2WP=Polycarbonate
Vandal/Weather Shield

Type
Incandescent
Incandescent
Incandescent
Halogen
Halogen
Incandescent
Incandescent
Halogen
Halogen

Wattage
8
8
8
8
8
7.2
7.2
8
8

Number
29-03
29-03
29-03
29-16
29-16
29-75
29-75
29-16
29-16

DESCRIPTION

DIMENSIONS

Sure-Lites’ HZU1254 Series
self-contained, explosionproof, emergency lighting unit
is intended for operation in
NEC Class I, Division 1, Groups
C, D, and Class II, Division 1,
Groups E, F, G environments.
The unit includes (2) 12V, 25W
lamps and provides a solidstate, emergency lighting system for application in industrial
and heavy-duty commercial
facilities like petrochemical
plants, drilling rigs, offshore
platforms, coal mines and
preparation facilities, textile
mills, lumber yards, painting
booths and gasoline stations.

HZU1254
SERIES
Hazardous Location
EMERGENCY LIGHTING

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model
HZU125425

DC Voltage

1 1/2 Hours

2 Hours

12

54

–

3 Hours

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: HZU125425

Model
Number
HZU125425

Accessories (Order separately)
12X25HZP=12V, 25W Pendant Mount Remote Head
12X25HZB=12V, 25W Bracket Mount Remote Head

Lamp Information
4 Hours
–

Type
Incandescent

Wattage

Number

25

ZZ13

> NEMA 4, copper-free
aluminum housing and
natural, textured die cast
aluminum finish enclosure

Emergency Lights

> Dual-voltage input
120/277VAC, 60Hz

E L E C T R I C A L R AT I N G S

INDUSTRIAL & HAZARDOUS LOCATION >

SURE-LITES®

> Lamp heads (two heads
standard) contains one
12V, 25W DC medium
base A-lamp
> Copper-free aluminum
lamp housing and guard
> Sealed Lead Calcium
Battery
> Watertight neoprene
gasketing
> One-way breather and
drain
> Explosion-proof

Energy Data

Model No.
HZU125425

Input Current (Max.):
120V
277V
.32A
.15A

> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/pilot light
> UL 924 Listed, Life Safety
NFPA 101, NEC Class I,
division 1, Groups C, D
and Class II, Division 1,
Groups E, F, G, OSHA,
most state and local codes

COOPER LIGHTING

69

Exit Lights

INDUSTRIAL & HAZARDOUS LOCATION >

SURE-LITES®
-49°F to +140°F

UX SERIES
Ultimate Exit
AC Only
S e l f - Po w e r e d

DESCRIPTION

DIMENSIONS

The Sure-Lites UX NEMA 4X LED Exit combines the
strength and durability of die cast aluminum with architecturally pleasing aesthetics. Designed for the most severe
environments, the UX exit will provide maximum performance against rain, moisture, cold, corrosives and dust.
Universal configurations (single and double face) and universal mounting provide the ease of one product specifying for any job. The injection molded, clear, polycarbonate
shield not only provides protection against moisture and
rain, but vandalism as well. (4) Torx® head tamperproof
screws with center-pin reject provide additional vandalproof security.
The unique design and features make the UX Exit compatible in food processing facilities, outdoor parking garages,
walk-in freezers and other indoor/outdoor severe environments. The UX Exit is approved for ambient environments
rated from -45°C (-49°F) up to +60°C (+140°F).

EXIT LIGHTING

> NEMA 4X Listed
> Operating temperature
-45°C (-49°F) to 60°C (+140°F)
> Dual voltage input 120/277
VAC, 60Hz Isolation
Transformer
> Die Cast aluminum housing
with powder coat finish

Self-Diagnostics

The self-diagnostic unit will automatically
perform the tests required by the NFPA 101
Life Safety Code. The system indicates the
status of the unit at all times using an LED
indicator that is located near the test
switch.

> LED Lamping
> Premium Nickel Cadmium
batteries
> Exit can be universally
mounted ceiling, wall or end

SPLASH ZONE

> Field selectable chevrons
> Universal pattern knockouts
on rear of single face
housing for direct mounting
to junction box

Verify proper operation of the
transfer circuit and emergency
lamps with a convenient laser
pointer (sold as an accessory).

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: UX61R

> Pendant mounting
> Watchguard EMS
Self-diagnostic system
> Laser Testing
> T6 HAZ lamp rating
> IP66, Ingress Protection
from IEC (International
Electrical Commission)
> UL844, Hazardous Locations
(Class 1, Division 2, Groups
A, B, C, D) with “HAZ”
option
> UL FTBR Listed when
specified with the “2C”
option

Family
UX=Nema
4X Exit
Series
6=AC Only, LED
7=Self-powered
Face Options
0=Universal
1
(single and double face)
1=Single

Housing
Finishes
Blank=Silver
BK=Black
WH=White

Factory
Options
95=AC Only
Fire
Alarm
Interface
90=DC Only
Fire
Alarm
Interface

SD=SelfDiagnostics
(Standard
for UX7
only)

Letter Colors
R=Red
G=Green

Options
2C=Two Circuit
Operation,
FTBR
HAZ=Hazardous
Locations
(Class 1,
Division 2,
Groups A,
B, C, D)
(Both can
be ordered)

Contains one single face exit and one UXUK.

VRSD=Vandal Resistant Screwdriver
LASER=Key Chain, Laser pointer (UX7
only), (activated at 30 ft.)

Energy Data — AC Only Exits

Input Power:

LED Exits -Red Letters
LED Exits -Green Letters

120V

277V

2.7W
2.3W

3.2W
3.0W

COOPER LIGHTING

Input Current (Max.):
120V 277V
LED Exits
.07A
.08A

Power Factor:

T.H.D.:

120V

277V

120V

277V

.04A
.03A

> .30
> .26

> .39
> .36

< 56% < 69%
< 54% < 67%

.04A
.04A

> .37
> .34

> .39
> .36

< 64% < 69%
< 63% < 67%

E n e rgy Da t a — S e l f - Powe re d E x i t s

LED Exits

> Patents Pending

70

UXUKWH=Converts single face exit to
double face exit. Contains (1) red lens,
(1) green lens, (1) White Exit Stencil,
(1) Vandal Shield & Tamperproof
Screws

UXPKA=Pendant Kit Adapter (fitting
adapts exit to 1/2" NPT threaded pendant "supplied by others")

1

> Cleanrooms Class 10,000
> UL 924 Wet Location
(Suitable for wet and damp
locations), Life Safety NFPA
101, Meets most state and
local codes

UXUK=Converts single face exit to
double face exit. Contains (1) red lens,
(1) green lens, (1) Standard Silver Exit
Stencil, (1) Vandal Shield &
Tamperproof Screws

UXUKBK=Converts single face exit to
double face exit. Contains (1) red lens,
(1) green lens, (1) Black Exit Stencil,
(1) Vandal Shield & Tamperproof
Screws

> Suitable for Floor Proximity
Installation, UL Listed, ADA
(American Disabilities Act)
> NSF National Sanitation
Foundation / Splash Zone
(for Food Processing)

Accessories (Order Separately)

LED Exits -Red Letters
LED Exits -Green Letters

3.4W
3.1W

3.2W
3.0W

.07A
.08A

DESCRIPTION

DIMENSIONS

The UMX Series watertight
and corrosion-resistant exit
with tough polycarbonate lens
is designed for use where rain,
moisture, dust or corrosives
are present. Economical long
life fluorescent lamps provide
highly visible signage and
downlighting. The vibration
resistant lamps make the UMX
perfect for heavy industrial
applications (NEMA 4X Listed).

We t L o c a t i o n
AC Only
S e l f - Powe re d

O R D E R I N G I N F O R M AT I O N — A C O N LY E X I T S
Voltage

Double
Arrow
UMX5
UMX51

Green Letters/White Background
No
Left
Right
Arrow
Arrow
Arrow
UMX3
UMX2
UMX4
UMX31
UMX21
UMX41

Double
Arrow
UMX1
UMX11

EXIT LIGHTING

> NEMA 4X Listed
O R D E R I N G I N F O R M AT I O N

> Dual-voltage input
120/277VAC, 60Hz

SAMPLE NUMBER: UMX7

Exit Lights

120 VAC
277 VAC

Red Letters/White Background
No
Left
Right
Arrow
Arrow
Arrow
UMX7
UMX6
UMX8
UMX71
UMX61
UMX81

UMX SERIES

INDUSTRIAL & HAZARDOUS LOCATION >

SURE-LITES®

> Gray fiberglass housing
Model Number
See chart

> Tough, high contrast
polycarbonate lens

Accessories (Order Separately)
WG7=Wire Guard
Vandal Shield VS2=Polycarbonate Vandal Shield
VS2WP=Polycarbonate Vandal
Shield/Weather Resistant

DC Socket Kit
UDC6=Two 6V, 6.6W DC Lamps
UDC12=Two 12V, 7.5W DC Lamps

> AC: two F6T5 fluorescent
lamps
> DC: two 6V, 6W DC lamps

O R D E R I N G I N F O R M AT I O N — S E L F - P O W E R E D E X I T S
Battery

Red Letters/White Background
No
Left
Right
Arrow
Arrow
Arrow
UMX207
UMX206
UMX208
UMX106
UMX226

Lead Calcium
Lead Calcium Battery
w/Remote Capability UMX107
Nickel Cadmium
UMX227

UMX108
UMX228

Double
Arrow
UMX205

Green Letters/White Background
No
Left
Right
Arrow
Arrow
Arrow
UMX203
UMX202
UMX204

Double
Arrow
UMX201

UMX105
UMX225

UMX103
UMX223

UMX101
UMX221

UMX102
UMX222

UMX104
UMX224

WAT TA G E R AT I N G S
UMX201 – UMX208
UMX101 – UMX108
UMX221 – UMX228

Lead Calcium=18W for 1 1/2 hrs.; 15W for 2 hrs.
Lead Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs.
Nickel Cadmium=15W for 1 1/2 hrs.; 12W for 2 hrs.

O R D E R I N G I N F O R M AT I O N

> For operation in ambient
temperatures above 32°F
> Self-powered Exits feature
line-latching, solid-state
voltage limited charger,
solid-state switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light
> UL 924 Wet Location
Listed

SAMPLE NUMBER: UMX207

Model Number
See chart

> Available with emergency
lighting heads mounted on
enclosure

Factory Options
DH=Two 6V, 7.2W Weatherproof Heads
(UMX101 thru UMX108 only)
TDM=Time Delay Monitor (Exits with Heads only)
TH=Thermal Heater for Battery Compartment (For Use
w/Lead Calcium Exits)

Accessories (Order Separately)
WG7=Wire Guard
Vandal Shield VS2=Polycarbonate Vandal Shield
VS2WP=Polycarbonate Vandal Shield/Weather Resistant

> Life Safety NFPA 101,
NEC/OSHA, most state
and local codes.

Energy Data — AC Only Exits

Fluorescent Exits-6W Lamps

Input Power;
120V
277V
19W
23W

UMX Exits
Input Current (Max.):
120V
277V
.33A
.32A

Power Factor:
120V
277V
>.47
>.26

T.H.D.:
120V
277V
<6%
<9%

E n e rgy Da t a — S e l f - Powe re d E x i t s
Charge Mode (Fully Discharged Battery) Sealed Lead Calcium Battery
Input Power;
Input Current (Max.):
Power Factor:
T.H.D.:
120V
277V
120V
277V
120V 277V
120V
277V
Fluorescent Exits - 6W Lamps
41W
43W
.51A
.22A
>.66
>.69
<14% <14%
Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 18 Watts in
the standby operating mode.

Fluorescent Exits - 6W Lamps

29W

Sealed Nickel Cadmium Battery
29W
.42A
.17A

>.57

>.62

<9%

<38%

COOPER LIGHTING

71

Exit Lights

INDUSTRIAL & HAZARDOUS LOCATION >

SURE-LITES®
DIMENSIONS

DESCRIPTION

VRX SERIES
Thin Profile
High-Abuse

The VRX Thin Profile HighAbuse Exit Series combines the
strength of die cast aluminum,
the profile of a recessed design
and the superior aesthetics of
Sure- Lites LED technology to
create an exit with optimum versatility and aesthetics. The VRX
Series faceplate/mounting
plate/lens is only 1" thick, yielding a sign with minimal
off-wall protrusion without
requiring the large wall opening
of a fully recessed exit. The VRX
Series also includes a Remote
Powered Exit which can be powered from a VRX Series AC Only
or Self Powered Exit.

A C O N LY / S E L F - P O W E R E D

R E M OT E P OW E R E D

AC Only
S e l f - Powe re d
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N - A C O N LY E X I T S / S E L F - P O W E R E D E X I T S
S A M P L E N U M B E R : V R X 6 10 0 0 0 R B

> Dual-voltage input 120/277
VAC, 60 Hz
> Die cast aluminum
faceplate exposed unit
thickness is 1”
> 20 gauge recessed
housing fits in 2x4
construction

Product Family
VRX=Thin
Profile,
High
Abuse

Series
Face Options
6=AC Only, 1=Single
LED
7=SelfPowered,
LED

> 18 gauge mounting plate
with clearance holes for
1/4" fasteners

Battery
00=AC Only,
120/277
(VRX6
only)
70=Nickel
Cadmium
Battery
(VRX7
only)

Factory Options
Letter Colors
00=No Options
R=Red
20=Flasher
G=Green
(VRX7 only)
30=Flasher/
Buzzer
(VRX7 only)
90=DC Fire
Alarm
Interface
(VRX7 only)
95=AC Only, Fire
Alarm Interface
(VRX6 only)

Faceplate Finishes
Blank=Brushed
Aluminum Face
with Black Trim
W=White
B=Black

> LED lamp panel provides
uniform light output
> Convex .125" polycarbonate Vandal Shield standard

O R D E R I N G I N F O R M AT I O N - R E M O T E P O W E R E D L E D E X I T S
S A M P L E N U M B E R : V R X 8 10 0 0 0 R B

> Centerpin Torx tamper
resistant screws
> NFPA compliant knockout
chevrons allow quick
conversion to directional
signs

Product Family
VRX=Thin
Profile,
High-Abuse

Series
8=Remote,
LED

Face Options
1=Single

Battery
00=Remote
Powered

Factory
Options
00=No Options

Letter Colors
R=Red
G=Green

> Adjustable hanger bars
> EPDM shock-absorbing
gasket between mounting
plate and wall
> Self-powered Exits feature
line-latching, solid-state
voltage limited charger,
solid-state switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/ power
indicator light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA, UL
Listed as suitable for floor
proximity installation,
most state and local codes

72

COOPER LIGHTING

Faceplate Finishes
Blank=Brushed
Aluminum Face
with Black Trim
W=White
B=Black

Energy Data

LED EXITS-AC ONLY
Input Power;
Input Current (Max.):
120V
277V
120V
277V
Red Letters Single Face
5.6W
5.7W
.07A
.03A
Red Letters Single Face with Remote
7.3W
7.3W
.07A
.03A
Green Letters Single Face
6.7W
6.8W
.07A
.03A
Green Letters Single Face with Remote 9.5W
9.7W
.09A
.04A
Remote Powered
Red Letters Single Face
2.0 watts additional
Green Letters Single Face
2.5 watts additional

Power Factor:
120V 277V
>.71
>.71
>.83
>.83
>.79
>.79
>.90
>.90

T.H.D.:
120V 277V
<36% <36%
<33% <34%
<30% <31%
<26% <27%

Power Factor:
120V 277V
>.72
>.72
>.84
>.84
>.79
>.79
>.90
>.90

T.H.D.:
120V 277V
<34% <34%
<31% <32%
<30% <31%
<26% <26%

Energy Data

Sealed Nickel Cadmium Battery-LED Exit
Input Power;
120V
277V
Red Letters Single Face
7.4W
7.5W
Red Letters Single Face with Remote
9.3W
9.5W
Green Letters Single Face
8.5W
8.7W
Green Letters Single Face with Remote 11.4W 11.7W

Input Current (Max.):
120V
277V
.08A
.04A
.08A
.04A
.09A
.04A
.11A
.05A

DIMENSIONS

DESCRIPTION

Tritium self-luminous exits are
illuminated by unique phosphor-coated sealed tubes filled
with Tritium gas which excites
the phosphor causing it to emit
visible light. No electrical supply is necessary, thereby eliminating costly electrical wiring,
energy and maintenance costs.

TRX1 SERIES
TRITIUM EXIT
Note: Special wording
available; consult
your Cooper Lighting
Representative.

TRITIUM
SELF-LUMINOUS
EXIT LIGHTING

O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : T R X 11 R W H 2 0

Family
TRX1=Tritium
Exit

Face Options
1=Single
2=Double

Background
Colors
R =Red
G =Green
BK=Black
Special wording
available; consult
your Cooper
Lighting
Representative.

Housing and
Frame Finishes
WH=White
BK =Black
AL =Aluminum
anodized
frame and
gray housing

Rated Life
10=10 years
20=20 years

Accessories (Order Separately)
CAX18PKWH=18” Pendant Kit, White
CAX18PKHTWH=18” Hang True Pendant
Kit, White
CAX18PKBK=18” Pendant Kit, Black
CAX18PKHTBK=18” Hang True Pendant
Kit, Black
WG1=Surface, Wire Guard
VS1=Polycarbonate Vandal Shield
IFSP=Institutional impact resistant housing, wall mount only.

Exit Lights

> Institutional Impact
resistant, Flaw resistant
housing is comprised of
a 13 gauge steel frame
with a 3/8" (10mm) thick
polycarbonate face

INDUSTRIAL & HAZARDOUS LOCATION >

SURE-LITES®

> The plastic housing is
ultrasonically welded to
the prismatic diffuser,
encapsulating the sealed
tubes and reflector without
the use of glue
> The sealed tubes are
made from borosilicate
glass which makes the
tubes shock resistant
> Exit can be ceiling, wall,
pendant or end mounted
> Field selectable chevrons
> Cased in a high-impact
flame retardant plastic
housing
> Tamperproof and vandal
resistant
> UL 924 (approved to1998
and 2001 requirements).
Life Safety NFPA 101.
Suitable for Wet Locations.
Suitable for use in
Hazardous, Explosive,
Humid and other Harsh
environments. OSHA,
NRC. Council of American
Building Official (BOCA,
ICBO, SBCC1)
> Exits are guaranteed for
their rated life (10 or 20
years) to exceed minimum
illumination requirements,
0.15 foot lamberts

I M P O R TA N T
Each order placed must include the installation location name and full address for NRC registration purposes.
Tritium exits must not be abandoned or disposed of. Call your Cooper Lighting representative for recycling information.

COOPER LIGHTING

73

Exit Lights

INDUSTRIAL & HAZARDOUS LOCATION >

SURE-LITES®
DIMENSIONS

DESCRIPTION

PHL SERIES
PHOTOLUMINESCENT
EXIT

Photoluminescent
Self-Luminous

Photoluminescent “glow-in-thedark” exits are designed to
absorb and store energy from
existing light sources. The signs
do not require electricity and are
non-radioactive, non-toxic, and
fire-resistant. This energy efficient exit is ideal for areas where
electrical wiring is either difficult
or unavailable. It is an excellent
choice when adding low level
exits. Possible applications
include: schools, offices, retail
stores and manufacturing plants.
The PHL Series exits do not
require regular maintenance and
have a life expectancy of at least
25 years.

EXIT LIGHTING

> Energizes from
Fluorescent Lighting
(Minimum 5 Ft-Candle of
Fluorescent Illumination
required during building
occupancy)
> 90 minutes of illumination
with a legible viewing distance of at least 50 feet

O R D E R I N G I N F O R M AT I O N - A C O N LY E X I T S / S E L F - P O W E R E D E X I T S
SAMPLE NUMBER: PHL1RBA

Product Family
PHL=
Photoluminescent
Exit

Face Options
1=Single
2=Double

Letter Colors
(Outline)
R=Red
G=Green

Housing Color
Blank=Same as
Letter Color
BA=Brushed
Aluminum

Accessories
PHLS=Clear Acrylic
Shield
PHLJ=Large Canopy
(J-Box)

> Heavy duty aluminum
housing is impact resistant, corrosion proof and
flame retardant
> High-brightness strontium
oxide aluminate photoluminescent pigment is
applied directly onto
housing
> Non-Radioactive and
Non-Toxic
> Ceiling, wall or end
mounting
> Field selectable chevrons
> UL 924 Listed, meets Life
Safety NFPA 101, ULC
Listed, most state and
local codes

B ru s h e d A l u m i n u m , R e d

B ru s h e d A l u m i n u m , G re e n

Red

Green

> Rated Life: 25+ years

74

COOPER LIGHTING

DIMENSIONS
END
MOUNT

DESCRIPTION
WA L L
MOUNT

P E N DA N T
MOUNT

The Sure-Lites HZX Series
Explosion-Proof Edgelit Exit
signs are designed for use
in locations classified as hazardous due to the presence of
flammable vapors, gasses
or combustible dust. They
are suitable for use in Class I,
Division 1, Groups C and D,
and Class II, Division 1,
Groups E, F and G hazardous
locations as defined by the
National Electrical Code.

HZX SERIES
Hazardous Location Exit
EXIT LIGHTING

Model Number
HZX21
HZX22
HZX23

Mounting Style
Wall
End
Pendant

Sign Panel
Single Face
Double Face
Double Face

> Factory-sealed, explosionproof housing of copperfree aluminum

Exit Lights

> 120 VAC input voltage
O R D E R I N G I N F O R M AT I O N

INDUSTRIAL & HAZARDOUS LOCATION >

SURE-LITES®

> Impact-resistant white
acrylic edgelit face panel
with 6" high red letters

N AT I O N A L E L E C T R I C A L C O D E ( N E C )

The National Electrical Code (NEC) defines a hazardous location as “a location where fire hazards or explosion
hazards may exist due to flammable gases or vapors, flammable liquids, combustible dust or ignitable fibers or
filings.
The Code further separates these hazardous locations into three classes:
Class I – locations containing gases and vapors
Class II – locations containing dust
Class III – locations containing fibers and filings.
Each of these classes is broken into divisions. These divisions are separated into groups according to characteristics.

Division
1 Hazard Exists – Always present
1 in atmosphere

2 Potential Exists – May be present
1 in atmosphere

II Dust

1 Hazard Exists
2 Potential Exists

III Fibers

1 Production Areas
2 Handling/Storage Areas

> Two 60W, 60T10 clear
lamps wired in parallel
> No provisions for
battery operation
> Provides safe operation
in the presence of volatile
gases, vapor or dust

The following chart summarizes these classifications:
Class
I Gas

> Available in pendantmount, wall-mount, or
end-mount styles

Group
A Acetylene
B Hydrogen and Manufactured Gases containing Hydrogen
C Petrochemicals
D Petrochemicals
A Acetylene
B Hydrogen and Manufactured Gases containing Hydrogen
C Petrochemicals
D Petrochemicals
E Conductive and Combustible Metal Dust
F Combustible Carbon Dust
G Non-Conductive Combustible Dust
Combustible
Combustible

> Internal rectifier extends
lamp life
> Relamping tool provided
> Listed per UL 844 for
hazardous locations up to
and including NEC Class I,
Division 1, Groups C, D
and Class II, Division 1,
Groups E, F and G, Life
Safety NFPA 101,
NEC/OSHA, most state
and local codes

Energy Data

Input Current (Max.):
Model No.
120V
277V
HZX21, HZX22, HZX23
120W
1.0A
ZZ14=60T10 Halogen lamp 120V 60Watt

COOPER LIGHTING

75

RETROFIT

SURE-LITES®
DIMENSIONS

DESCRIPTION

FBP SERIES

When AC power fails,
the Sure-Lites FBP
Emergency Battery
Pack automatically
switches to emergency mode. It maintains illumination of
one or two lamps for
a minimum of 90 minutes. UL924 Listed for
field retrofit installation.

Fluorescent
B a tte r y Pa ck

Model

Dimensions
A
9.4”
9.4”
9.4”
13.3”
13.3”
13.3”
9.4”
9.4”
16.3”
14.1”

FBP140X
FBP240U
FBP240M
FBP240H
FBP240HU
FBP240HSD
FBP240C
FBP240D
FBP3500
FBP450LP

B
2.4”
2.4”
2.4”
2.4”
2.4”
2.4”
2.4”
2.4”
5.5”
1.5”

C
1.5”
1.5”
1.5”
1.5”
1.5”
1.5”
1.5” (Flex=28”L)
1.5” (Flex=28”L)
1.7” (Flex=28”L)
1.0”

E L E C T R I C A L R AT I N G S A N D O R D E R I N G I N F O R M AT I O N
EMERGENCY LIGHTING
Model
FBP140X

> Dual-voltage input
120/277VAC, 60Hz
> Universal voltage 120 to
277 VAC, 50/60 Hz
(FBP240HU)
> Sealed nickel cadmium
batteries
> Solid-State charger,
overload/short-circuit
protection, test switch/
power indicator light
> Can be installed inside or
on top of fixture
> May be used with
switched or unswitched
fixtures

FBP240U

FBP240M

FBP240H

FBP240HSD 17W-215W, 2’-8’, T8-T12 HO, VHO, U-shaped,
circleline, energy saving, rapid start (4-pin,
2G11, G24q, or GX24q) twin, quad and triple
twin-tube compacts

COOPER LIGHTING

One

600-700

One–20W to 215W (2'-8')
One–20W to 39W long compact fluorescent
One or Two–20W to 40W (2'-4')
One or Two - 17W to 24W
One or Two - 32W to 40W (2'-4')
One - 40W to 215W (5'-8')
One or Two -18W to 39W
long compact fluorescent
One or Two - 18W to 32W
4-Pin compact fluorescent
One or Two-17W to 40W (2"-4")
One-40W to 215W (5'-8')
One or Two-18W to 39W long
compact fluorescent
One-40W to 55W long
compact fluorescent
One or Two-18W to 42W 4-pin
compact fluorescent
One or Two-17W to 40W (2"-4")
One-40W to 215W (5'-8')
One or Two-18W to 39W long
compact fluorescent
One-40W to 55W long
compact fluorescent
One or Two-18W to 42W 4-pin
compact fluorescent
One or Two–6W to 28W tubular
One or Two–13W to 39W or
One–42W 4-pin compact fluorescent

600-700

1100-1400
(700-1000 for long
compact fluorescent)

1100-1400
(700-1000 for long
compact fluorescent)

FBP240C

6W-28W tubular without integral starter,
13W-42W 4-pin twin, quad, or triple twin-tube
compact fluorescent without integral starters

FBP240D

18W-26W quad tube with integral starter in
two pin base

One-18W to 26W compact fluorescent

300-650

FBP450LP

32W, 4’, T8

One

450

FBP3500

17W-215W, 2'-8', T-8-T12 HO, VHO,
U-shaped circleline, energy saving and
(4-pin, 2G11, G24Q, or GX240) twin,
quad and triple twin-tube compacts

One or Two-17W to 40W (2"-4")
One-40W to 215W (5'-8')
One or Two-18W to 39W long
compact fluorescent
One-40W to 55W long
compact fluorescent
One or Two-18W to 42W 4-pin
compact fluorescent

1450-3500

> Low Profile (FBP450LP)

76

Initial Lumens
350-450

17W-215W, 2’-8’, T8-T12 HO, VHO, U-shaped,
circleline, energy saving, rapid start (4-pin,
2G11, G24q, or GX24q) twin, quad and triple
twin-tube compacts

> Self Diagnostic
(FBP240HSD)

> UL 924 Listed, UL Listed
for Retrofit/ Field
Installation, Chicago
Approved, Life Safety
NFPA 101, NEC/OSHA,
most state and local
codes

Number of Lamps
Operated in Emergency Mode
One

FBP240HU

> Compatible with many
different lamp types
> Compatible with many
ballast types including
standard, rapid-start,
slimline, instant-start,
energy saving, dimming
and electronic AC ballasts consult your Cooper
Lighting Representative
regarding specific
applications

Lamp Type
20W-40W, 2'-4', T8-T12 U-shaped, circleline,
2D, energy saving, rapid start (4-pin, 2G11)
long compact fluorescent
17W-215W, 2'-8', T8-T12 HO, VHO, U-shaped,
circleline, 2D, energy saving, rapid start
(4-pin, 2G11) long compact fluorescent
17W-215W, 2’-8’, T8-T12 HO, VHO, U-shaped,
circleline, 2D, energy saving, rapid start
(4 pin, 2G11) long compact fluorescent
17W-215W, 2'-8', T8-T12 HO, VHO, U-shaped,
circleline, energy saving, rapid start (4-pin,
2G11 or G24q) long compact fluorescent

O R D E R I N G I N F O R M AT I O N

Energy Data

SAMPLE NUMBER: FBP140X

FBP140X
FBP240U
FBP240M
FBP240H
FBP240HSD
FBP240HU
FBP240C
FBP240D
FBP3500
FBP450LP

Accessories
(Order separately)
FBP1WBC=Wire Bundle Cover for
external mount applications
(2 required)

Model No.
FBP140X
FBP240U
FBP240M
FBP240H
FBP240HSD
FBP240HU
FBP240C
FBP240D
FBP3500
FBP450LP

Input Power
120V
4.5W
5.3W
5.3W
5.8W
4.0W
6.0W
5.3W
3.5W
8.0W
1.5W

1100-1400
(700-1000 for long
compact fluorescent)

300-750

DESCRIPTION

DIMENSIONS

In the event of AC power
loss, the Sure-Lites LTC1,
Load Transfer Circuit,
automatically switches
normal light fixtures to
approved emergency
lights. The LTC1 in conjunction with an auxiliary
emergency power generator, will provide emergency power to lighting
fixtures regardless of the
room switch position. The
LTC1 will operate up to a
maximum10A load. The
LTC1 is UL924 listed for
field retrofit installation.

RETROFIT

SURE-LITES®

LTC1 SERIES
L o a d Tr a n s f e r C i r c u i t
EMERGENCY LIGHTING

> 120VAC and 277VAC, 60Hz
available
> Test Switch/3 LED Indicator
Lights for: Utility Power,
Emergency Power, Test
Modes
> Operates incandescent,
fluorescent, HID and other
loads; 10 Amps Max
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : LT C 11 2 0 V

> Sized to fit inside ballast
channel

LTC1
Family
LTC1=Load Transfer
Circuit

> Matte black painted steel
housing with conduit BX
connector standard

Voltage
120V=120VAC
277V=277VAC

> Can be installed inside,
on top of fixture or remote
from fixture
> May be used with
switched fixtures
> Compatible with many
different lamp types
> Compatible with many
ballast types including
standard, rapid-start,
slimline, instant-start,
energy-saving, dimming
and electronic AC ballasts consult Cooper Lighting
Representative regarding
specific applications
> UL 924 Listed (dry locations), UL Listed for
Retrofit/ Field Installation,
Life Safety NFPA 101,
NEC/OSHA

COOPER LIGHTING

77

RETROFIT

SURE-LITES®
DIMENSIONS

DESCRIPTION

LTC2 SERIES
L o a d Tr a n s f e r C i r c u i t
EMERGENCY LIGHTING

In the event of AC
power loss, the SureLites LTC2, Load
Transfer Circuit, automatically switches normal light fixtures to
approved emergency
lights. The LTC2, in conjunction with an auxiliary emergency power
generator or inverter,
will provide emergency
power to lighting fixtures regardless of the
room switch position.
The LTC2 will operate
up to a maximum10A
load. The LTC2 is UL924
listed for field retrofit
installation.

> 120/277VAC, 60Hz available
> Operates incandescent,
fluorescent, HID and other
loads; 10 Amps Max
> Matte black painted steel
housing
> Sized to fit inside ballast
channel
> Can be installed inside or
on top of fixture
> May be used with
switched fixtures
> Compatible with many
different lamp types
> Compatible with many
ballast types including
standard, rapid-start,
slimline, instant-start,
energy-saving, dimming
and electronic AC ballastsconsult Cooper Lighting
Representative regarding
specific applications
> UL 924 Listed (dry
locations), UL Listed for
Retrofit/ Field Installation,
Life Safety NFPA 101,
NEC/OSHA

78

COOPER LIGHTING

O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : LT C 2

LTC2
Family
LTC2=Load Transfer
Circuit

Voltage
Blank=120/277VAC

DIMENSIONS

DESCRIPTION

• 120 VAC, 60 Hz input voltage
• Long-life, high-output LEDs
• Consumes less than 1 watt per lamp (2W per
kit)
• MOV (Metal Oxide Varistor) surge protected
• Patent pending
• LEDs (Light Emitting Diodes) are encapsulated
in a standard T-6 1/2 glass lamp envelope
• Super-clear glass and super-bright LEDs combine for optimum light output
• Available in two base styles: candelabra and
intermediate
• Simple screw-in installation - no special
adapters or messy rewiring
• Direct replacement for up to 20W incandescent lamps
• Two lamps provided per kit

The Sure-Lites LED LITE STIX™ LED
Retrofit Kit for Exits offers the latest
technology in exit lighting available
today. The Patent Pending design of
the LED LITE STIX™ provides superior illumination of exit lettering at a
fraction of the costs associated with
typical incandescent lamps. Each kit
is provided with two lamps which
come in two different base styles to
suit nearly every application.
Installation is easy since the lamps
simply screw into the existing incandescent lamp sockets. The long life
characteristic of the LEDs is protected
by an integral MOV (Metal Oxide
Varistor) surge protection device
which is designed to protect the lamp
in the event of an electrical surge.
Practically any stencil face incandescent exit fixture can be retrofitted
with the Sure-Lites LED LITE STIX™
LED Retrofit Kit for Exits, yielding significant energy savings and eliminating the lamp maintenance associated
with incandescent lamps. The kit is
suitable for use with either single or
double face exit fixtures.
• No special provisions required for
installation:
1. Disconnect AC power and open
exit fixture
2. Remove existing AC
incandescent lamps
3. Screw-in LED LITE STIX™
4. Close exit fixture and reconnect
AC power
• Damp Location Listed
• UL 924 Classified for Sure-Lites
Exits, Life Safety NFPA 101, CSA
Certified, NEC/OSHA, Most state
and local codes
• Suitable for use with single- or double-face exit fixtures
• Eliminates lamp replacement costs
and maintenance labor
• Trilingual instructions included
(English, Spanish, and French)
• Diffuser can also be used to convert
green exits to red

O R D E R I N G I N F O R M AT I O N

Energy Data

SAMPLE NUMBER: RKRC

RKRC, RKRI (per 2-lamp kit)
Input Power:
120V = 2.0W
Input Current (Max.):
120V = .09A
Power Factor:
120V = >.19
T.H.D.:
120V = <19%

RK
Family
RK=LED LITE
STIX™
LED
Retrofit Kit

Lamp Color
R=Red

Base Style
C=Candelabra
I=Intermediate

Accessories (order separately)
RKLR=Diffuser - Red - 13" x 9"

RETROFIT

SURE-LITES®

RKRC SERIES
LED Lite Stix™
Exit Retrofit Kit
EXIT LIGHTING

RKRI SERIES
LED Lite Stix™
Exit Retrofit Kit
EXIT LIGHTING

COOPER LIGHTING

79

RETROFIT

SURE-LITES®
DIMENSIONS

DESCRIPTION

REM SERIES
Remote Emergency
Module
EMERGENCY LIGHTING

The REM Series is used to convert a non-emergency fixture
to an emergency fixture when
combined with a 12V DC emergency power source.
Provides transfer capability
only - module does not contain
batteries. REM240 will operate
with 12V DC incandescent
lamps up to 85W maximum.
Each module operates one
lamp.

E L E C T R I C A L R AT I N G S A N D O R D E R I N G I N F O R M AT I O N

Model

Battery

Used With

Rated Wattage

Wattage Consumed
in Emergency Mode*

REM240

None

12V DC Incandescent lamp

85W (Max.)

Lamp Wattage plus 0.9W

* Lamp wattage included except where noted

DIMENSIONS

DESCRIPTION

RBP SERIES
Remote Fluorescent
B a tte r y Pa ck

The Sure-Lites RBP Series
Remote Battery Pack enables
the conversion of nearly any
standard compact fluorescent
fixture into an emergency
lighting fixture. The RBP Series
is a complete conversion system in that it contains everything required for the conversion including batteries, electronics and test switch. On two
lamp fixtures it illuminates one
lamp in emergency mode. It
may be wired to a switched or
unswitched fixture (277VAC
applications which use 120V
ballasted fixtures require the
EMS277 Switching Accessory).

EMERGENCY LIGHTING
E L E C T R I C A L R AT I N G S

Model

Battery

Used With

Initial Lumen Output

Emergency Mode
Illumination Time

RBP9
RBP9347
RBP13
RBP13347
RBP1826
RBP1826347

12V Sealed Lead Calcium
12V Sealed Lead Calcium
12V Sealed Lead Calcium
12V Sealed Lead Calcium
12V Sealed Lead Calcium
12V Sealed Lead Calcium

7W or 9W 2-Pin Compact Fluorescent Lamp (One lamp only)
7W or 9W 2-Pin Compact Fluorescent Lamp (One lamp only)
13W 2-Pin Compact Fluorescent Lamp (One lamp only)
13W 2-Pin Compact Fluorescent Lamp (One lamp only)
18W or 26W 2-Pin Compact Fluorescent Lamp (One lamp only)
18W or 26W 2-Pin Compact Fluorescent Lamp (One lamp only)

98% of lamp rating
98% of lamp rating
98% of lamp rating
98% of lamp rating
98% of lamp rating
98% of lamp rating

120 minutes
120 minutes
120 minutes
120 minutes
120 minutes
120 minutes

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: RBP9

Model Number
RBP9
RBP13
RBP1826

80

COOPER LIGHTING

Accessories
(Order separately)
EMS277=Accessory for 277V
Switching Applications

O R D E R I N G I N F O R M AT I O N
277V Canopy Conversion Kit
Catalog Number
PLC277P
PLC277B
AD277CAX
AD277CAXW
AD277CAXBZ
CAN277ELX
CCX277

DESCRIPTION

Color
White
Black
Black
White
Bronze
N/A
N/A

For use with
R/G/CX/OF/PLX Series Steel Exits
R/G/CX/OF/PLX Series Steel Exits
CAX Series Exits
CAX Series Exits
CAX Series Exits
ELX Series Exits
CCX Series Exits

FTBR Conversion Canopy - CAX Series Incandescent Exits
(For use with CAX Series AC only, incandescent and screw-in LED exits with brushed aluminum, white or black housing finish)
Description
Universal Input 120V or 277V
120V Input Only
One 120V Input and one
277V Input

For use with
CAX2100XXG, GB, GW, R, RB, RW and
CAX2200XXG, GB, GW, R, RB, RW

Finish Codes: B-Black, BZ-Bronze, W-White. Add suffix to Catalog Number when ordering.
FTBR Conversion Canopy - Steel Series LED Exits
(For use with R/G Series LED fixtures, SLX Series)
Catalog Number
PLC2CU

277V
CONVERSION
CANOPIES

DESCRIPTION

O R D E R I N G I N F O R M AT I O N

Catalog Number
AD2CUCAX
AD2C120CAX
AD2C1277CAX

PLC/AD/CAN Series Canopy
Conversion Kit
• Kit for converting 120 VAC
Only Exits to 277V operation.
• 277 VAC Input, 120 VAC
Output
• Two transformers included
• Allows wiring of AC lamps
on separate circuits
• PLC Series – 20 gauge steel
canopy
• AD Series – Die cast canopy
• CAN277ELX installs inside
standard ELX housing

RETROFIT

SURE-LITES®

Description

For use with
G1LED, G1CLED, G2CLED,
G2CXLED, G1277LED, G2277LED,
G2277CLED, G2277CXLED, R1LED,
R1CLED, R2CLED, R2CXLED,
R1277LED, R2277LED, R2277CLED,
R2277CXLED

PLC2C120
PLC2C1277

Finish Codes: B-Black, P-White. Add suffix to Catalog Number when ordering.

Canopy housing made of 20 gauge steel (PLC Series) or die cast aluminum (AD Series). UL 924,Life Safety NFPA 101, UL FTBR Listed when
used with correlated Exit Lights.

PLC/AD Series FTBR Conversion
Canopies
Canopy used to field convert an
AC Only Exit which is UL Listed
in Category FWBO - Exit Fixtures
to an exit which is UL Listed in
category FTBR - Emergency
Lighting and Power Equipment.
Exits employing these canopies
are intended to be connected
simultaneously to normal and
emergency power circuits.
Three input voltage types are
available:
1) Universal:
120/277V Normal Power and
120/277V Emergency Power
2) 120V Normal Power and
120V Emergency Power
3) 120V Normal Power and
277V Emergency Power
or
277V Normal Power and
120V Emergency Power

FTBR
CONVERSION
CANOPIES

DESCRIPTION

O R D E R I N G I N F O R M AT I O N
Catalog Number Suffix
FL1

Description
DC Flasher

BZ1

DC Buzzer

For use with
CCX, UN, UNH, EAX,
PLX, CAX (Incandescent only)
and CAR (Incandescent only)
UN, UNH, PLX,
CAX (Incandescent only) and
CAR (Incandescent only)

Flasher Kit
Kit for flashing the DC lamps
of exits during the emergency
operation mode.
Buzzer Kit
Kit provides an audible signal
during the emergency
operation mode of exits.

FLASHER/
BUZZER KIT

COOPER LIGHTING

81

RETROFIT

SURE-LITES®
DESCRIPTION

EMERGENCY
POWER PACK

Standard Emergency Power
Pack for converting AC Only
incandescent or fluorescent
steel exits to self-powered
emergency exits (DC lamp kit
included).
Dual-voltage input 120/277 VAC,
60Hz, line-latching, Solid-state
voltage limited charger, SolidState switching, low-voltage
disconnect, brownout circuit,
overload/short-circuit protection, test switch/power indicator light, may be specified with
self-diagnostics option (use
“SD” suffix).

DESCRIPTION

CAX
EMERGENCY
POWER PACK

82

COOPER LIGHTING

Emergency Power Pack
for converting AC Only
Incandescent CAX Series Exits
to Self-Powered Emergency
Exits (DC Lamp Kit included).
Dual-voltage input 120/277 VAC,
60Hz, line-latching, Solid-state
voltage limited charger, SolidState switching, low-voltage
disconnect, brownout circuit,
overload/short-circuit protection, test switch/power indicator
light.

O R D E R I N G I N F O R M AT I O N
Emergency Power Pack (Rated Wattage to 87 1/2% of Rated D.C. Voltage)
Catalog No.
Color
1 1/2 Hours
2 Hours
Comments
EPX5000P
White
10.8
7.2
When used with PLX Series
Steel Exits, one additional DC
lamp is required (Total: 3 lamps)
– Order DCE6 or DCE63
EPX5000B
Black
10.8
7.2
(Total: 3 lamps) – Order DCE6
or DCE63

•
•
•
•
•
•
•

22 gauge steel housing
Choice of two finishes
Sealed lead calcium battery
Maintenance free, long life
Full recharge time, 24 hrs. (max.)
Polarized battery terminals
Two 6V, 3.6W DC wedge base lamps included

O R D E R I N G I N F O R M AT I O N
Emergency Power Pack (Rated Wattage to 87 1/2% of Rated D.C. Voltage)
Catalog No.
Color
1 1/2 Hours
2 Hours
Comments
CAX3PP
Black
10.8
7.2
CAX Series Incandescent
Exits and CAX/LED ACR
CAX3PPW
White
10.8
7.2
CAX Series Incandescent
Exits Only
CAX3PPBZ
Bronze
10.8
7.2
CAX Series Incandescent
Exits and CAX/LED ACR

•
•
•
•

Die cast canopy with electronics package
Choice of three finishes
Sealed Lead Calcium Battery,
Two 6V, 3.6W DC wedge base lamps included

O R D E R I N G I N F O R M AT I O N
Cat. No. Length
VS1

VS1WP

VS2

VS2WP

Height

DESCRIPTION
Depth

For use with

21" (533mm) 11" (279mm) 10" (254mm) AA, CAX, CC, CCX (AC only or Self-Powered),
CHX (AC only), CU, LM, P4C, PLX (AC only),
R/G/CX/OF, CX, LPX (without heads), ST Series;
Remote Heads
21" (533mm) 11" (279mm) 10" (254mm) AA, CAX, CC, CCX (AC only or Self-Powered),
CHX (AC only), CU, LM, P4C, PLX (AC only),
R/G/CX/OF, CX, LPX (without heads), ST Series;
Remote Heads
21" (533mm) 19" (483mm) 11" (279mm) CCX (with Heads), CHX (Self-Powered),
UN/UNH (Self-Powered or with Heads), HR,
NCB (except NCB12225), PLX (Self-Powered or
with Heads), LPX (with heads), UMB, XR
Series, CC7, CC8
21" (533mm) 19" (483mm) 11" (279mm) CCX (with Heads), CHX (Self-Powered),
UN/UNH (Self-Powered or with Heads), HR,
NCB (except NCB12225), PLX (Self-Powered or
with Heads), LPX (with heads), UMB, XR Series
CC7, CC8

Length
18" (457mm)

WG2

18" (457mm)

WG3

23" (584mm)

WG4
WG5
WG6
WG7

32"
16"
26"
16"

WG8
WG9

8" (203mm)
16" (406mm)

WG10

13 3⁄4" (349mm)

WGS11

13 5⁄8" (346mm)

WG12

27 1⁄2" (698mm)

WG17

27 1⁄2" (698mm)

WG19

21" (533mm)

(812mm)
(406mm)
(660mm)
(406mm)

• Self-adhesive closed-cell
neoprene gaskets provided
with “WP” weather resistant
versions
• “WP” weather resistant
versions are provided with
gasketed breather vent
UL 924 Rain Test (SD4.6), UL
924 Water Shield Impact
Test (SD4.10)

POLYCARBONATE
VANDAL SHIELD/
WEATHER SHIELD

DESCRIPTION

O R D E R I N G I N F O R M AT I O N
Catalog No.
WG1

• Made of durable, highimpact, UV-resistant clear
polycarbonate material

ACCESSORIES

SURE-LITES®

Height
15" (381mm)

Depth
6" (152mm)

For use with
CC, LM1, AA, XR, CU2, CAX
(Incandescent/
Fluorescent, Self- Powered,
Surface Mount) Series
15" (381mm)
10" (254mm)
PLX (with heads),
UNH (with heads),
CCX (with heads) &
CHX (with heads)
20" (508mm)
12" (305mm)
HR180, HR12170, HR12210,
HR12360, NCB45, NCB90,
NCB110, NCB1290,
NCB12180 Series, CC7, CC8
21" (533mm)
12" (305mm)
NCB12225 Series
16" (406mm)
14" (356mm)
SLC1, CFR1 Series
16" (406mm)
14" (356mm)
SLC2, CFR2 Series
16" (406mm)
9" (229mm)
P4C, RLM, RD, R4C, HR87,
HR117, HR12117, UMB,
UMX Series
8" (203mm)
8" (203mm)
Single Head Remotes
8" (203mm)
8" (203mm)
Double Head Remotes,
ST1
13 3⁄8" (340mm) 4 3⁄8" (111mm) R, G, CX, UN, UNH, PLX,
CCX, SLX, LPX/LPXH, INCX,
TRX, CAX (Incandescent/
Fluorescent, AC), CAX-LED
Series (Surface Mount
Only—CU2), CHX
16 3⁄4" (425mm) 4" (102mm)
R, G, CX, UN, UNH, PLX,
CCX, SLX, LPX/LPXH, CAX,
INCX, TRX Series (End or
Ceiling Mount Only), CHX
14" (356mm)
8" (203mm)
GC Series,
LPX (with heads-wall)
12" (305mm)
14 1⁄2" (368mm) GC Series
LPX (with heads-ceiling or
wall)
15" (381mm)
6" (152mm)
CU1 Series

O R D E R I N G I N F O R M AT I O N

Wire Guards
• All metal wire guard for exits
or emergency units
• .177" (5mm) diameter 7
gauge steel round wire
• Non reflective zinc plated finish
• Hinged sides hook in place
(except WGS11 which is not
hinged)
• Screw eyes provided
for mounting

WIRE GUARDS

DESCRIPTION

Pendant Kits
Catalog No.
PK18WH

Finish
White

Length
18"

PK18BK

Black

18"

CCX18PKWH
CCX18PKBK
CAX18PKWH

White
Black
White

18"
18"
18"

CAX18PKBK

Black

18"

CAX18PKBZ

Bronze

18"

For use with
R/G/CX/OF/SLX/UN/UNH/
PLX Series Steel Exits
R/G/CX/OF/SLX/UN/UNH/
PLX Series Steel Exits
CCX/LPX Series Exits
CCX/LPX Series Exits
CAX Series Exits with
incandescent or compact
fluorescent lamps which are
120/277VAC Only or are
self-powered emergency; all CAX
Series Exits with LED lamps,
CX6 & CX7 Series, HR Series and
CU2 Series

Pendant Kit
• Pendant Kit for pendant
mounting of exits
• No electrical components
• Includes canopy, mounting
hardware, threaded stem
and attachment bracket
• CAX Series Pendant Kit may
require CAX Series Splice
Box

PENDANT KITS

Note: Contact Cooper Lighting Representative for Custom Lengths

COOPER LIGHTING

83

ACCESSORIES

SURE-LITES®
DESCRIPTION

HANG-TRUE
PENDANT KIT

Hang-True Pendant Kit
• Pendant Kit for mounting of
exit signs on sloped ceilings
up to 45°
• No electrical components
• Includes canopy, mounting
hardware, threaded stem
and attachment bracket
• CAX Series Hang-True
Pendant kit may require
CAX Series splice box

O R D E R I N G I N F O R M AT I O N
Hang-True Pendant Kits
PK18HTWH

White

18"

PK18HTBK

Black

18"

CCX18PKHTWH
CCX18PKHTBK
CAX18PKHTWH

White
Black
White

18"
18"
18"

CAX18PKHTBK

Black

18"

CAX18PKHTBZ

Bronze

18"

R/G/CX3/OF/UNH/PLX/SLX
Series Steel Exits
R/G/CX3/OFUNH/PLX/SLX
Series Steel Exits
CCX/LPX Series Exits
CCX/LPX Series Exits
CAX Series Exits with
incandescent or compact
fluorescent lamps which are
120/277VAC Only or are
self-powered emergency; all CAX
Series Exits with LED lamps,
CX6 & CX7 Series and CU2 Series

Note: Contact Cooper Lighting Representative for Custom Lengths

DESCRIPTION

CANOPY KITS

Canopy Kit
• Canopy for end or top
mounting of exits. No electrical components
• CAN Series – Impact-resistant, injection molded thermoplastic
• QE Series – Die cast 380
aluminum alloy
• Includes mounting plate and
mounting hardware

DESCRIPTION

CAX SERIES
SPLICE BOX

84

COOPER LIGHTING

CAX Series Splice Box
• Splice Box provides wire
splicing compartment for
CAX Series Exits with incandescent or compact fluorescent lamps which are 277V
AC Only or are self-powered
and employ a CAX Series
Pendant Kit.
Note: This accessory is not
required for CAX-LED Series
Exits

O R D E R I N G I N F O R M AT I O N
Canopy Kits
Catalog No.
CAN571
CAN578

Finish
White
Black

For use with
R/G/CX3/OF/UN/UNH/PLX/SLX Series Steel Exits
R/G/CX3/OF/UN/UNH/PLX/SLX Series Steel Exits

O R D E R I N G I N F O R M AT I O N
CAX Series Splice Box
Catalog No.
CAXSBOXWHSP

Finish
White

CAXSBOXBKSP

Black

CAXSBOXBZSP

Bronze

For use with
Required for CAX Series Exits with incandescent
or compact fluorescent lamps which are
277V AC Only or are self-powered and utilize any
CAX Series Pendant Kit
277V AC Only or are self-powered and utilize any
CAX Series Pendant Kit

DESCRIPTION

O R D E R I N G I N F O R M AT I O N
Catalog No.
EMS277

•
•
•
•

Description
277V Switching Accessory

For use with
H-274-EM, RBP Series

No electrical components
18 gauge die formed steel
Specify white, black, or bronze finish
Installs directly to Pendant Kit stem and above 277V canopy or
self-powered power pack

For use with
Almost any emergency unit or
self-powered exit

O R D E R I N G I N F O R M AT I O N
Cordsets
Catalog Number
CSK120
CSK277
Voltmeter
Catalog Number
VK1

SWITCHING
ACCESSORIES

DESCRIPTION

O R D E R I N G I N F O R M AT I O N
Remote Test Switch & Pilot Light
Catalog No. Description
1RTPL
Remote Test Switch & Pilot Light

277V Switching Accessory
Switching Kit required for
277V installations with RBP
Series,
H274EM. Enables fixture to be
turned off without activating
the emergency mode while
maintaining a charge to the
batteries. If a power failure
occurs, the fixture switches to
emergency mode and illuminates. 277 VAC operation.
Requires switched and
unswitched 277 VAC connections.One EMS-277 Switching
Accessory required per fixture
to be switched. Mounts to fixture junction box.

ACCESSORIES

SURE-LITES®

Description
120V Cordset
277V Cordset with standard NEMA L7-20P plug
Description
Voltmeter (Range: 0-15 Volts)

Remote Test Switch
& Pilot Light
• Supplied with wiring pigtails
• Power indicator lamp
• Test switch allows battery
and lamp check from
remote location
• Wires to 120 VAC
• Check local codes for maximum fixture to test switch
distance

REMOTE TEST
SWITCH &
PILOT LIGHT

DESCRIPTION

Cordsets
• Accessory Cordsets for use
with units and unswitched
24- hour supply outlets.120V
or 277V three prong
3' cordsets
• Field Installed Voltmeter
allows check of battery output. Voltage range is 0-15
Volts. Provides convenient
indication of battery voltage

CORDSETS

COOPER LIGHTING

85

ACCESSORIES

SURE-LITES®
DESCRIPTION

Mounting Brackets & Shelves
• Mounting Brackets and
Shelves simplify installation
of Emergency Lighting Units
• 18 gauge steel brackets, 20
Gauge steel Shelves
• Available in Grey, Black and
White finishes – specify color
when ordering

O R D E R I N G I N F O R M AT I O N
Mounting Brackets
Catalog No.
Description
1BR_ _*
Mounting Brackets (set of 2)
3BR_ _*
Mounting Brackets (set of 3)
Mounting Shelves
Catalog No. Description
1MS_ _*
Mounting
Shelf
2MS_ _*
Mounting
Shelf
3MS_ _*
Mounting
Shelf

Length
14"
(356mm)
15 3/4"
(400mm)
17 3/4"
(451mm)

For use with
CC, LM1, AA Series, ST1, and XR Series
HR Series and NCB Series

Height
10"
(254mm)
12"
(305mm)
13 1/2"
(343mm)

Depth
4"
(102mm)
7 1/4"
(184mm)
8 3/4"
(222mm)

*Finish Codes: GY–Grey, BK–Black, WH–White – Add suffix to catalog number when ordering
(eg. 1MSGY)

MOUNTING
BRACKETS,
MOUNTING
SHELVES

DESCRIPTION

Recessing Kits
• Recessing Kits allow fully
recessed or semi-recessed
installation of P4C Series
Emergency Unit and R4C
Series Remote. No electrical
components
• 20 gauge steel mounting box
• Two piece adjustable bar
hangers span up to 24"

O R D E R I N G I N F O R M AT I O N
Recessing Kits for P4C Series
Catalog Number
Description
FRK1
Fully Recessing Kit
USF1

Semi-Recessing Kit

For use with
P4C Series Emergency Unit, R4C
Series Remote
P4C Series Emergency Unit, R4C
Series Remote

RECESSING
KITS

TAMPERPROOF
SCREWS &
SCREWDRIVER
BITS

86

COOPER LIGHTING

DESCRIPTION

O R D E R I N G I N F O R M AT I O N

Tamperproof Screws &
Screwdriver Bits
• Tamperproof Screws and
Screwdriver Bit for use in
Steel Exits
• Restricts access to internal
exit or emergency lighting
unit compartments
• Ideally suited for use in
schools, hotels, public places
of assembly, etc
• Increases the likelihood that
the product will be functional in an emergency situation

Tamperproof Screws & Screwdriver Bits
Catalog No.
Description
TPK1CP
Four #6 Centerpin Torx Zinc Plated
Pan Head Sheet Metal Screws
0590A638SP

One #6 Centerpin Torx Screwdriver Bit

059012SP
0590A639SP

One #8 Centerpin Torx Screwdriver Bit
One #8 Heavy Duty Centerpin Torx

VRSD
VRSPD

One #8 Centerpin Torx Screwdriver
One #6 Spanner Screwdriver

For use with
R/G/CX/OF/EP/EPH/UN/UNH/PLX
Series Steel Exits, XR, AA, HR
and NCB Series
R/G/CX/OF/EP/EPH/UN/UNH/PLX
Series Steel Exits, XR, AA, HR
and NCB Series
VP Series Exits
TPX Series Exits
Screwdriver Bit
CAR, CAX, CCX, UX, UEL Series
“STL” StairLite

DIMENSIONS

DESCRIPTION

15 1/4”
[389mm]

6 3/16”
[157mm]

6 11/16”
[169mm]

Laser Test

Self-Diagnostics

The self-diagnostic unit will automatically
perform the tests required by the NFPA 101 Life
Safety Code. The system indicates the status of
the unit at all times using an LED indicator that
is located near the test switch.

The Sure-Lites UEL NEMA 4X
Emergency Light is designed for
those emergency lighting applications where ruggedness and
dependability are a must. Designed
for the most severe environments,
the UEL Emergency Light will provide maximum performance
against rain, moisture, cold, corrosives and dust.
The UEL’s standard features
include a die cast housing, nickel
cadmium battery, self-diagnostics,
photocell LASER test and MR16
lamps. In addition, an injection
molded, polycarbonate shield
provides protection against moisture, rain, and vandalism. (4) Torx
head tamperproof screws with
center-pin reject provide additional
vandal-proof security.
The unique design and features
make the UEL Emergency Light
compatible in food processing
facilities, outdoor parking garages,
walk-in freezers and other indoor/
outdoor severe environments.

CHICAGO CODE

SURE-LITES®

UEL SERIES
Ultimate Emergency
Light

CHICAGO CODE
EMERGENCY LIGHTING

> NEMA 4X, UL50 Listed
> Dual-voltage input
120/277VAC, 60Hz,
Isolation Transformer
> Die cast aluminum
housing with powder
coat finish
> (2) Adjustable MR16 lamps

Verify proper operation of the
transfer circuit and emergency
lamps with a convenient laser
pointer (sold as an accessory).

SPLASH ZONE

> Nickel Cadmium Battery
> Fully recharged in 24
hours
> Vandal Proof

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage

Lamp Information

Model

DC Voltage

1 1/2 Hours

Type

Wattage

Number

Spacing1

UEL1SD

12

24

MR16

12

29-141

50.0'

> UV stable, glass-clear
polycarbonate, vandal
resistant shield (.150”
thick) with Torx head
tamperproof screws,
stainless steel

O R D E R I N G I N F O R M AT I O N

> T1 Haz Lamp Rating

SAMPLE NUMBER: UEL1SDC

> Watchguard EMS
Self-Diagnostic System

UEL1
Family
UEL1=Nema 4X
Emergency
Light

SD
Housing
Finishes
Blank=Silver
BK=Black
WH=White

C
C=City of Chicago
Approved

SD=Self Diagnostics
(Standard)

Options

Accessories (order separately)

A=Ammeter
V=Voltmeter

LASER=Key Chain, Red Laser Pointer
(activation tested at 30 feet)

TDM=Time Delay
Monitor

0590-12SP=#8 Centerpin Torx
Screwdriver Bit
UXPKA=Pendant Kit Adapter (fitting
adapts to 1/2" NPT threaded
pendant)

Energy Data

Model No.
UEL1SD

Input Current (Max.):
120V
277V
.09A
.03A

> Photocell Test Switch
(requires accessory LASER
for activation)
> UL 924 Outdoor Wet
Location Listed (suitable
for wet and damp locations)
> NSF, National Sanitation
Foundation/Splash Zone
(for Food Processing)
> IP66, Ingress Protection
from IEC (International
Electrical Commission)
> Cleanroom Class 10,000
> Patent Pending

1The

"Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 feet ceiling with a 6 feet wide walkway and 3 feet path of egress.
The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees.
Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid,
not as guarantee of any code compliance.

> City of Chicago approved

COOPER LIGHTING

87

CHICAGO CODE

SURE-LITES®
DESCRIPTION

CHEL SERIES
Die Cast Aluminum

DIMENSIONS

The Sure-Lites CHEL Emergency Light
provides a distinct solution to any
emergency lighting application.
Constructed of die cast aluminum, the
CHEL presents not only a unique shape
and design but also provides dependable strength and durability. The two,
fully adjustable, high efficiency 12W
MR16 lamps provide maximum path of
egress performance. The standard
Watchguard EMS self-diagnostic system
meets NFPA 101 testing requirements
providing assurance that the unit is
working properly at all times. The SureLites LASER test feature allows remote,
30 second confidence testing of the
emergency light upon demand.

CHICAGO CODE
EMERGENCY LIGHTING

Self-Diagnostics

The self-diagnostic unit will
automatically perform the tests
required by the NFPA 101 Life
Safety Code. The system
indicates the status of the unit at
all times using an LED indicator
that is located near the test
switch.

> Dual Voltage input,
120/277 VAC, 60 Hz
> Die cast aluminum
housing with powder coat
finish

Verify proper operation of the
transfer circuit and emergency
lamps with a convenient laser
pointer (sold as an accessory).

> Two 6V 12W MR16 lamps
> Sealed Lead Calcium
Battery
> Watchguard EMS
Self-Diagnostic System
> Photocell Test Switch
(requires accessory LASER
for activation)
> UL924 Listed, Damp
location listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes
> City of Chicago Approved

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model
CHEL1SD

DC Voltage
6

Lamp Information

1 1/2 Hours

Type

Wattage

Number

Spacing1

24

MR16

12

29-140

50'

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: 6CHEL1SD

CHEL1
Family
CHEL1=Architectural
Emergency
Light

1The

SD
Housing
Finishes
Blank=Silver
BK=Black
WH=White

SD=Self Diagnostics
(Standard)

Options

Accessories (order separately)

TDM=Time Delay Monitor

LASER=Key Chain, Red Laser Pointer
(activation tested at 30 feet)

"Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress.
The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.5. Cooper Lighting assumes no responsibility for
local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.

88

COOPER LIGHTING

DIMENSIONS

DESCRIPTION

The XR Series is an efficient,
rugged, commercial grade
emergency light.
Most units have the extra
capacity to power remote
heads for added application
flexibility.

11 1/4”
[286mm]
2 1/4”
[57mm]

4 1/2”
[114mm]

2 1/4”
[57mm]

12 1/4”
[311mm]

CHICAGO CODE

SURE-LITES®

XR6C
XR1624C
XR16C

6 1/8”
[156mm]

Figure 1

14 1/2”
[368mm]

1 7/8”
[48mm]

XR7C
XR9C
XR20C
XR21C
XR12206C
XR12208C

7 3/4”
[197mm]

6 1/8”
[156mm]
12 1/4”
[311mm]

2 1/2”
[64mm]

Figure 2

XR SERIES
E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model

Type

DC Voltage

XR6C
XR7C
XR9C*
XR1624C
XR16C
XR20C
XR21C
XR12206C
XR12208C

SLC
SLC
SLC
SNC
SNC
SNC
SNC
SLC
SLC

6
6
6
6
6
12
12
12
12

Lamp Information

1 1/2 Hours Lamp Watts Remote Watts
27
36
54
24
50
30
50
36
54

24
24
24
24
24
24
24
24
24

Figure

3
12
30
0
26
6
26
12
30

1
2
2
1
1
2
2
2
2

Type

Wattage

Number

12
12
12
12
12
12
12
12
12

29-66
29-66
29-66
29-66
29-66
29-45
29-45
29-45
29-45

Halogen
Halogen
Halogen
Halogen
Halogen
Halogen
Halogen
Halogen
Halogen

Steel

CHICAGO CODE
EMERGENCY LIGHTING

> Dual-voltage input
120/277VAC, 60Hz
> 22 gauge die formed steel

*XR9C is UL Listed for 4 hours with 24 watt lamp load only – No remote load
SLC=Sealed Lead Calcium
SNC=Sealed Nickel Cadmium

> White finish
> Two fully adjustable metal
heads with die cast swivel top mounted

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: XR6C

> Sealed Lead Calcium or
Premium Nickel Cadmium
batteries
Model Number
XR6C
XR1624C
XR16C
XR7C
XR9C
XR20C
XR21C
XR12206C
XR12208C

Options (add as suffix)
Alternate Lamps1
A=Ammeter2
SD=Self Diagnostics3
TDM=Time Delay Monitor
V=Voltmeter2
Other Options1

> Knockout, conduit or
cord set

A c c e s s o ri e s (order separately)
1BRWH=Mounting Brackets (2) - White
1MSWH=Mounting Shelf - White

> Universal J-box mounting
pattern, keyhole slots

VK1=Voltmeter
WG1=Wire Guard

> Remote capability

E N E R G Y D ATA

Model No.

Input Current (Max.):

XR6C

120V= .21A

277V= .10A

XR20C

120V= .08A

XR7C

120V= .20A

277V= .09A

XR21C

120V= .11A

277V= .05A

XR9C

120V= .21A

277V= .10A

XR12206C

120V= .29A

277V= .13A

XR1624C

120V= .08A

277V= .03A

XR12208C

120V= .28A

277V= .12A

XR16C

120V= .08A

277V= .04A

1Consult Cooper Lighting Representative. 2XR6C,
3XR7C, XR9C, XR16C not available with SD.

Model No.

Input Current (Max.):
277V= .03A

> Line-latching, solid-state
voltage limited charger,
solid-state switching, lowvoltage disconnect,
brownout circuit, overload/short-circuit protection,
test switch/power indicator
light
> UL 924 Listed , Life Safety
NFPA 101, NEC/OSHA,
most state and local codes.
> City of Chicago approval
Number 3238

XR1624 and XR16C housings have provision for one meter only.

COOPER LIGHTING

89

CHICAGO CODE

SURE-LITES®
DESCRIPTION

The real workhorse in emergency lighting systems...these durable, reliable units are unparalleled in performance and provide freedom from maintenance.
The HR Series units provide a low cost, solid-state lighting system for applications in industrial, commercial, or multi-housing environments. High and Ultra High capacity makes them ideal for installations
where a large number of heads/exits will be remotely operated.
DIMENSIONS

HR87C
HR117C
HR12117C
Steel
High Capacity

Figure 2. High Capacity

Figure 1. Ultra High Capacity

HR180C
HR12170C
HR12210C
HR12360C
Steel
Ultra-High Capacity
CHICAGO CODE
EMERGENCY LIGHTING

> Dual-voltage input
120/277VAC, 60Hz

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model

Type

DC Voltage

HR87C
HR117C
HR12117C
HR180C
HR12170C
HR12210C
HR12360C

SLC
SLC
SLC
SLC
SLC
SLC
SLC

6
6
12
6
12
12
12

Lamp Information

1 1/2 Hours Lamp Watts Remote Watts
87
117
117
180
170
210
360

24
24
24
24
24
24
24

63
93
93
156
146
186
336

Figure
1
1
1
2
2
2
2

Type
Halogen
Halogen
Halogen
Halogen
Halogen
Halogen
Halogen

Wattage

Number

12
12
12
12
12
12
12

29-66
29-66
29-45
29-66
29-45
29-45
29-45

*Batteries may be shipped separately.
SLC=Sealed Lead Calcium

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: HR87CTDM

> 18 gauge die formed steel
housing and cover
> White finish
> Two top mounted, fully
adjustable, white, metal
heads with die-cast swivel
standard

Model Number
HR87C
HR117C
HR12117C
HR180C
HR12170C
HR12210C
HR12360C

Options (add as suffix)
Alternate Lamps1
A=Ammeter
V=Voltmeter
TDM=Time Delay Monitor
Other Option1

> Sealed lead-calcium battery
> Knockout, conduit or cord set
> Remote capability
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit, overload/short-circuit protection,
test switch/power indicator
light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA, most
state and local codes
> City of Chicago approval
Number 3238

90

Energy Data

Model No.
HR87C
HR117C
HR12117C
HR180C
HR12170C
HR12210C
HR12360C

1Consult

COOPER LIGHTING

Input Current (Max.):
120V
277V
.50A
.21A
.53A
.22A
.26A
.13A
.98A
.43A
1.08A
.45A
1.02A
.47A
1.17A
.54A

your Cooper Lighting Representative.

Accessories (order separately)
VK-1 =Voltmeter
3BRWH =Mounting Brackets, White Finish
2MSWH =Mounting Shelf, White Finish (For High Capacity Fixtures)
3MSWH=Mounting Shelf, White Finish (For Ultra High Capacity
Fixtures)
CSK120=Cord Set 120VAC
CSK277=Cord Set 277VAC
VS2=Polycarbonate Vandal Shield
WG7=Wire Guard, For High Capacity Fixtures
WG3=Wire Guard, For Ultra High Capacity Fixtures

DESCRIPTION

DIMENSIONS

The GC Series combines a
clean, sleek, contemporary
appearance with state-of-theart electronics. Specifically
designed for initial and retrofit
installations where a recessed
unit is required to maximize
aesthetics. The unit is ideal for
locations with limited wall
space and where panoramic
positioning is necessary for the
ceiling mounted lampholders
to provide proper light distribution. Ideal for stores, offices,
hospitals and school corridors.

6 3/4”
(171mm)

CHICAGO CODE

SURE-LITES®

GC SERIES
Steel
Recessed
CHICAGO CODE
EMERGENCY LIGHTING

> Dual-voltage input
120/277VAC, 60Hz

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model

DC Voltage

GC15072
1
GC15072CL
GC15082
1
GC15082CL

6
6
6
6

2 Hours
24
24
48
48

Lamp Information

3 Hours

4 Hours

18
18
36
36

14
14
28
28

Type
Halogen
Halogen
Halogen
Halogen

Wattage

Number

12
12
12
12

29-15
29-15
29-15
29-15

> 20 gauge die-formed steel
housing
> White finish
> Metal heads available in
round or cylinder styles
> Heads match housing
finish

O R D E R I N G I N F O R M AT I O N

> Knockout, conduit or cord
set

SAMPLE NUMBER: GC15072V

Model Number
GC15072
GC15072CL1
GC15082
GC15082CL1

Options ( add as suffix)
Alternate Lamps 2
A=Ammeter
SD=Self Diagnostics (GC15072, GC15072CL Only)
TDM=Time Delay Monitor
V=Voltmeter
Other Options 2

E N E R G Y D ATA

Model No.
GC15072, GC15072CL
GC15082, GC15082CL

Input Current (Max.):
120V
277V
.12A
.05A
.12A
.05A

Accessories (Order Separately)
VK1=Voltmeter
WG12=Wire Guard

> Flanged for mounting
in grid type suspended
ceilings
> Single modular electrical
connector
> Line-latching, solid-state
voltage limited charger,
solid-state switching,
low-voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test switch/
power indicator light
> UL 924 Listed , Life Safety
NFPA 101, NEC/OSHA,
most state and local codes.
> City of Chicago approval
Number 3238
> Chicago Plenum mark
(CCEA - City of Chicago
Environmental Air)

1CL=Cylinder

Type Heads. 2Consult your Cooper Lighting Representative.

COOPER LIGHTING

91

CHICAGO CODE

SURE-LITES®
DESCRIPTION

DIMENSIONS

An attractive, compact emergency lighting unit, the ST1 is
a packaged in a flame-resistant metal housing. It is ideal
for providing emergency lighting in commercial and institutional environments where
appearance and ease of installation are critical.

ST1 SERIES
Steel
CHICAGO CODE
EMERGENCY LIGHTING

> Dual-voltage input
120/277VAC, 60Hz
> 18 gauge die formed steel
housing

E L E C T R I C A L R AT I N G S

Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model
ST1

DC Voltage

1 1/2 Hours

6

27

2 Hours
24

> Two side mounted fully
adjustable heads, glare
free lens
> White finish
> Knockout, conduit or cord
Set
O R D E R I N G I N F O R M AT I O N

> Universal J-box mounting
pattern, keyhole slots
> Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low-voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test switch/
power indicator light
> UL 924 Listed , Life Safety
NFPA 101, NEC/OSHA,
most state and local codes.
> City of Chicago approval
Number 0590E

92

COOPER LIGHTING

SAMPLE NUMBER: ST1

Model Number
ST1

Accessories (Order Separately)
1BRWH=Mounting Brackets (2) - White
1MSWH=Mounting Shelf - White
VK1=Voltmeter
WG9=Wire Guard

E N E R G Y D ATA

Model No.
ST1

Input Current (Max.):
120V
277V
.12A
05A

Lamp Information
Type

Wattage

Tungsten Halogen 12

Number
29-66

DIMENSIONS

DESCRIPTION

Model

Dimensions
A
9.4”
9.4”
9.4”
13.3”
9.4”
9.4”
16.3”

FBP140X
FBP240U
FBP240M
FBP240H
FBP240C
FBP240D
FBP3500

B
2.4”
2.4”
2.4”
2.4”
2.4”
2.4”
5.5”

C
1.5”
1.5”
1.5”
1.5”
1.5” (Flex=28”L)
1.5” (Flex=28”L)
1.7” (Flex=28”L)

When AC power fails,
the Sure-Lites FBP
Emergency Battery
Pack automatically
switches on. It maintains illumination of
one or two lamps for
a minimum of 90 minutes. UL Listed for
field retrofit installation.

CHICAGO CODE

SURE-LITES®

FBP SERIES
Fluorescent
B a tte r y Pa ck

E L E C T R I C A L R AT I N G S A N D O R D E R I N G I N F O R M AT I O N
Model
FBP140X

FBP240U

FBP240M

FBP240H

Lamp Type
20W-40W, 2'-4', T8-T12 U-shaped, circleline,
2D, energy saving, rapid start (4-pin, 2G11)
long compact fluorescent
17W-215W, 2'-8', T8-T12 HO, VHO, U-shaped,
circleline, 2D, energy saving, rapid start
(4-pin, 2G11) long compact fluorescent
17W-215W, 2’-8’, T8-T12 HO, VHO, U-shaped,
circleline, 2D, energy saving, rapid start
(4 pin, 2G11) long compact fluorescent
17W-215W, 2'-8', T8-T12 HO, VHO, U-shaped,
circleline, energy saving, rapid start (4-pin,
2G11 or G24q) long compact fluorescent

CHICAGO CODE

Number of Lamps
Operated in Emergency Mode
One

Initial Lumens
350-450

One

600-700

> Dual-voltage input
120/277VAC, 60Hz

One–20W to 215W (2'-8')
One–20W to 39W long compact fluorescent
One or Two–20W to 40W (2'-4')
One or Two - 17W to 24W
One or Two - 32W to 40W (2'-4')
One - 40W to 215W (5'-8')
One or Two -18W to 39W
long compact fluorescent
One or Two - 18W to 28W
quad compact fluorescent
One or Two–6W to 28W tubular
One or Two–13W to 32W or
One–42W 4-pin compact fluorescent

600-700

> Compatible with many
different lamp types

1100-1400
(700-1000 for long
compact fluorescent)

> Sealed nickel cadmium
batteries

300-750

> Solid-State charger,
overload/short-circuit
protection, test switch/
power indicator light

FBP240C

6W-28W tubular without integral starter,
13W-42W 4-pin twin, quad, or triple twin-tube
compact fluorescent without integral starters

FBP240D

18W-26W quad tube with integral starter in
two pin base

One–18W to 26W compact fluorescent

300-650

FBP3500

17W-215W, 2'-8', T-8-T12 HO, VHO,
U-shaped circleline, energy saving and
(4-pin, 2G11, G24Q, or GX240) twin,
quad and triple twin-tube compacts

One or Two-17W to 40W (2"-4")
One-40W to 215W (5'-8')
One or Two-18W to 49W long
compact fluorescent
One-40W to 55W long
compact fluorescent
One or Two-18W to 42W 4-pin
compact fluorescent

1450-3500

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: FBP140X

FBP140X
FBP240U
FBP240M
FBP240H
FBP240C
FBP240D
FBP3500

Accessories
(Order separately)
FBP1WBC=Wire Bundle Cover for
external mount applications
(2 required)

EMERGENCY LIGHTING

> Can be installed inside or
on top of a fixture
> May be used with
switched or unswitched
fixtures
> Compatible with many
ballast types including
standard, rapid-start,
slimline, instant-start,
energy-saving, dimming
and electronic AC ballasts consult your Cooper
Lighting Representative
regarding specific applications
> UL 924 Listed, UL Listed
for Retrofit/ Field
Installation, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes
> Chicago approved

Energy Data

Model No.
FBP140X
FBP240U
FBP240M
FBP240H
FBP240C
FBP240D
FBP3500

Input Power
120V
4.5W
5.3W
5.3W
5.8W
5.3W
3.5W
8.0W

COOPER LIGHTING

93

CHICAGO CODE

SURE-LITES®
DESCRIPTION

A C L E D S E R I E S O N LY

DIMENSIONS

The Sure-Lites CHX Series
Exits are the ideal exits for
general purpose applications.
An extensive range of field
installed accessories, choice
of faces, and the variety
of possible mounting
configurations permit the
tailoring of this exit to almost
any application. Durable steel
construction, attractive styling,
and high efficiency
illumination make this series
compatible in commercial,
institutional, and multihousing applications.

6 3/4”
[171mm]
4 1/2”
[114mm]

2 5/16”
[59mm]

7/8”
[22mm]

9”
[229mm]

12 1/4”
[311mm]

Incandescent, Fluorescent, CHX4 and CHX2 Series

CHX SERIES
6 3/4”
[171mm]
4 1/2”
[114mm]

Steel

2 5/16”
[59mm]

AC Only
7/8”
[22mm]
4 1/2”
[114mm]

CHICAGO CODE
EXIT LIGHTING

14 3/8”
[365mm]
9”
[229mm]

> Dual 120/277 VAC input
voltage, LED only

> 120 VAC input voltage,

12 1/4”
[311mm]

Incandescent and
Fluorescent only

LED, CHX6 Series

> 20 gauge steel housing,
white finish

> LED, Incandescent, or
Fluorescent lamping

> Universal pattern knockouts
on rear for direct mounting
to junction box

> Steel canopy (where
supplied) allows ceiling or
end mounting

> Full length 3/4" stroke arrow
on directional exits

> Red silkscreened lettering
on white translucent, heat
tempered, Impact-resistant
glass lens

> Other open face lenses
available – consult Cooper
Lighting Representative

S T E E L E X I T S - A C O N LY
Type

Mounting

No Arrow

Arrow Right

Arrow Left

Double Arrow

Wall
Wall/Ceiling/End
Ceiling/End

CHX203
CHX203C
CHX218C

CHX206
CHX206C
CHX221C

CHX209
CHX209C
CHX221C

CHX212
CHX212C
CHX224C

Wall
Wall/Ceiling/End
Ceiling/End

CHX403
CHX403C
CHX418C

CHX406
CHX406C
CHX421C

CHX409
CHX409C
CHX421C

CHX412
CHX412C
CHX424C

CHX Series Exits
AC Only Incandescent
Single Face
Single Face w/Canopy
Double Face w/Canopy
AC Only Fluorescent
Single Face
Single Face w/Canopy
Double Face w/Canopy
AC Only LED
Single Face

Wall

CHX603

CHX606

CHX609

CHX612

Single Face w/Canopy
Double Face w/Canopy

Wall/Ceiling/End
Ceiling/End

CHX603C
CHX618C

CHX606C
CHX621C

CHX609C
CHX621C

CHX612C
CHX624C

O R D E R I N G I N F O R M AT I O N

Energy Data

SAMPLE NUMBER: CHX203

> Lens installs from side of
fixture for more convenient,
safe maintenance

> Louvered downlight
standard

> UL Damp Location Listed
> UL 924 Listed , Life Safety
NFPA 101, NEC/OSHA,

> City of Chicago Approved

Model Number
See chart
above

Accessories (Order
Separately)
DC Socket Kit1
DCE6=Two 6V, 3.6W DC
Lamps
DCE12=Two 12V, 3.6W DC
Lamps
Canopy Kit
CHX1C=White
Power Pack1
CHX3500P=White
277V Conversion Canopy1
PLC277P=White
Pendant Kit
PK18WH=White, 18" Long

94

COOPER LIGHTING

Wire Guard
Choose size of wire guard
desired from Accessories
sheet
“STAIR” Lens
004260SP=No Arrow
004261SP=Arrow Left
004262SP=Arrow Right
004263SP=Double Arrow
“EXIT” Lens
004213SP=No Arrow
004214SP=Arrow Left
004215SP=Arrow Right
004216SP=Double Arrow

Model No.
CHX - Incandescent

Input Power
120V
277V
40W
44W

Model No.
CHX - Fluorescent

Input Power
120V
277V
14W
23W

Model No.
CHX - LED

120V
7W

1Incandescent

Input Power
277V
7W

and Fluorescent Fixtures Only.

DIMENSIONS

DESCRIPTION

6 3/4”
[171mm]
4 1/2”
[114mm]

The Sure-Lites CHX Series
Exits are ideal exits for
general purpose applications.
An extensive range of field
installed accessories, choice
of faces and the variety of
possible mounting
configurations permit the
tailoring of this exit to almost
any application. Durable steel
construction, attractive styling
and high efficiency
illumination make this series
compatible in commercial,
institutional, and multihousing applications.

2 5/16”
[59mm]
7/8”
[22mm]
4 1/2”
[114mm]
14 3/8”
[365mm]
9”
[229mm]

6 1/2”
[165mm]

12 1/4”
[311mm]

7 5/8”
[194mm]

CHICAGO CODE

SURE-LITES®

STEEL EXITS - SELF-POWERED
Type

Mounting

Self Powered Incandescent
Single Face
Wall
Single Face w/Canopy
Wall/Ceiling/End
Double Face w/Canopy
Ceiling/End
Self Powered Incandescent – High Output
Single Face
Wall
Single Face w/Canopy
Wall/Ceiling/End
Double Face w/Canopy
Ceiling/End
Self Powered Incandescent With Double Heads
Single Face
Wall
Single Face w/Canopy
Wall/Ceiling/End
Double Face w/Canopy
Ceiling/End
Self Powered Fluorescent
Single Face
Wall
Single Face w/Canopy
Wall/Ceiling/End
Double Face w/Canopy
Ceiling/End
Self Powered Fluorescent – High Output
Single Face
Wall
Single Face w/Canopy
Wall/Ceiling/End
Double Face w/Canopy
Ceiling/End
Self Powered Fluorescent With Double Heads
Single Face
Wall
Single Face w/Canopy
Wall/Ceiling/End
Double Face w/Canopy
Ceiling/End
Self Powered LED2
Single Face
Single Face w/Canopy
Double Face w/Canopy

Wall
Wall/Ceiling/End
Ceiling/End

No Arrow

Arrow Right

Arrow Left

Double Arrow

CHX303
CHX303C
CHX318C

CHX306
CHX306C
CHX321C

CHX309
CHX309C
CHX321C

CHX312
CHX312C
CHX324C

CHXH303
CHXH303C
CHXH318C

CHXH306
CHXH306C
CHXH321C

CHXH309
CHXH309C
CHXH321C

CHXH312
CHXH312C
CHXH324C

CHX303DH
CHX303DHC
CHX318DHC

CHX306DH
CHX306DHC
CHX321DHC

CHX309DH
CHX309DHC
CHX321DHC

CHX312DH
CHX312DHC
CHX324DHC

CHX503
CHX503C
CHX518C

CHX506
CHX506C
CHX521C

CHX509
CHX509C
CHX521C

CHX512
CHX512C
CHX524C

CHXH503
CHXH503C
CHXH518C

CHXH506
CHXH506C
CHXH521C

CHXH509
CHXH509C
CHXH521C

CHXH512
CHXH512C
CHXH524C

CHX503DH
CHX503DHC
CHX518DHC

CHX506DH
CHX506DHC
CHX521DHC

CHX509DH
CHX509DHC
CHX521DHC

CHX512DH
CHX512DHC
CHX524DHC

CHX703
CHX703C
CHX718C

CHX706
CHX706C
CHX721C

CHX709
CHX709C
CHX721C

CHX712
CHX712C
CHX724C

WAT TA G E R AT I N G
CHX Series=7.2W for 2 hrs.;CHXH Series=7.2W for 4 hrs., 32W for 1 1/2 hrs.(7.2W plus 24W Remote);CHX Double Head Series=32W for 1 1/2 hrs.
SAMPLE NUMBERS: CHX Series CHX303, High Output Series CHXH303, CHX Double Head Series CHX303DH

Wire Guard
Choose size of wire guard
desired from Accessories
sheet
“STAIR” Lens
004260SP=No Arrow
004261SP=Arrow Left
004262SP=Arrow Right
004263SP=Double Arrow

1Incandescent

Model No.
CHX - Incandescent

Input Power
120V
277V
52W
52W

Model No.
CHX - Fluorescent

Input Power
120V
277V
23W
23W

Accessories (order separately)

Canopy Kit
CHX1C=White

CHICAGO CODE
EMERGENCY LIGHTING

> Dual-voltage input
120/277VAC, 60Hz
> 20 gauge steel housing,
white finish
> LED, Incandescent or
Fluorescent lamping
> Universal pattern knockouts on rear for direct
mounting to junction box

Energy Data

SAMPLE NUMBER: CHX303

Pendant Kit
PK18WH=White, 18" long

Steel
S e l f - Po w e r e d

> Full length, 3/4" stroke
arrow on directional exits

O R D E R I N G I N F O R M AT I O N

Model Number
See chart above

CHX/CHXH
SERIES

“EXIT” Lens
004213SP=No Arrow
004214SP=Arrow Left
004215SP=Arrow Right
004216SP=Double Arrow
Remote Head—6V, 12W Single
Head1
6T12MHWH—Two Maximum
Remote Head—6V, 12W Each
Double Head1
6T12DMHWH—One Maximum

Input
Power
Model No.
CHX - LED2

120V
11W

277V
12W

Standby Mode (Fully Charged)
Sealed Lead Calcium Battery
Input Power consumption is reduced by
approximately 7 Watts in the standby
operating mode for incandescent and
fluorescent exits.

> Red silkscreened lettering
on white phosphorescent,
heat tempered, Impactresistant glass lens
> Lens installs from side of
fixture
> Louvered downlight
> Line-latching, solid-state
voltage limited charger,
solid-state switching, lowvoltage disconnect,
brownout circuit, overload/short-circuit protection, test switch/power
indicator light
> UL 924 Listed , Life Safety
NFPA 101, NEC/OSHA
> City of Chicago Approved

and Fluorescent Fixtures Only. 2Chicago Approved LED Fixtures Uses Long Life NI-CD Batteries, Standard.

COOPER LIGHTING

95

CHICAGO CODE

SURE-LITES®
DESCRIPTION

DIMENSIONS

The Sure-Lites EAC Exit Series
combines clean, functional
styling with the design benefits
and durability of aluminum construction. The EAC Exit is compatible with any decor for use in
ceiling, wall or end-mount applications.

EAC SERIES
120V AC

277V AC

E x t ru d e d A l u m i n u m
AC Only

CHICAGO CODE

E X T R U D E D A L U M I N U M - A C O N LY

EXIT LIGHTING

Type

Mounting

No Arrow

Arrow Right

Arrow Left

Double Arrow

Wall
Wall
Wall/Ceiling/End
Wall/Ceiling/End
Ceiling/End
Ceiling/End

EAC10003
EAC10013
EAC20003
EAC20013
EAC300018
EAC300118

EAC10006
EAC10016
EAC20006
EAC20016
EAC300021
EAC300121

EAC10009
EAC10019
EAC20009
EAC20019
EAC300021
EAC300121

EAC100012
EAC100112
EAC200012
EAC200112
EAC300024
EAC300124

Wall
Wall
Wall/Ceiling/End
Wall/Ceiling/End
Ceiling/End
Ceiling/End

EAC12003
EAC12013
EAC22003
EAC22013
EAC320018
EAC320118

EAC12006
EAC12016
EAC22006
EAC22016
EAC320021
EAC320121

EAC12009
EAC12019
EAC22009
EAC22019
EAC320021
EAC320121

EAC120012
EAC120112
EAC220012
EAC220112
EAC320024
EAC320124

AC Only Incandescent

> 120 VAC input voltage
> Extruded aluminum
housing with mitered
corners and a satin
anodized aluminum
finish
> AC incandescent: two 20W
T6 1/2 intermediate base
lamps

Single Face (120V)
Single Face (277V)
Single Face w/Canopy (120V)
Single Face w/Canopy (277V)
Double Face w/Canopy (120V)
Double Face w/Canopy (277V)
AC Only Fluorescent
Single Face (120V)
Single Face (277V)
Single Face w/Canopy (120V)
Single Face w/Canopy (277V)
Double Face w/Canopy (120V)
Double Face w/Canopy (277V)

> AC fluorescent: two 7W
compact fluorescent lamps
> AC lamps on separate
circuits
> Universal pattern knockouts on rear for direct
mounting to junction box
> Canopy (where supplied)
allows ceiling or end
mounting
> Full length 3/4" stroke
arrow on directional exits

O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : E A C 10 0 0 3

Model
Number
See chart above

> Red silkscreened lettering
on white translucent, heat
tempered, impact resistant
glass lens

Accessories (Order Separately)
DC Socket Kit
DCE6=Two 6V, 3.6W DC Lamps
DCE12=Two 12V, 3.6W DC Lamps
Canopy Kit
QE1030SP=Aluminum Finish

> Other open face lenses
available – consult factory

Pendant Kit
H2639=Aluminum Finish, 15" Long

> Lens installs from side of
fixture

WG10=Wire Guard
WGS11=Wire Guard (for canopy mount without heads)

> Louvered downlight

“STAIR” Lens
004380SP = Arrow Left
004381SP = Arrow Right
004382SP = Double Arrow
004383SP = No Arrow

> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA
> City of Chicago Approved

Energy Data

Model No.
Incandescent
Fluorescent

96

COOPER LIGHTING

Input
120V
40W
15W

Power
277V
44W
23W

DIMENSIONS

DESCRIPTION

The Sure-Lites EAC Exit Series
combines clean, functional
styling with the design benefits
and durability of aluminum construction. The EAC Exit is compatible with any decor for use in
ceiling, wall or end-mount applications.

CHICAGO CODE

SURE-LITES®

EAC SERIES
E x t ru d e d A l u m i n u m
S e l f - Powe re d

EXTRUDED ALUMINUM - SELF-POWERED
Type

CHICAGO CODE

Mounting

No Arrow

Arrow Right

Arrow Left

Double Arrow

Wall
Wall/Ceiling/End
Ceiling/End

EAC40003
EAC50003
EAC600018

EAC40006
EAC50006
EAC600021

EAC40009
EAC50009
EAC600021

EAC400012
EAC500012
EAC600024

Wall
Wall/Ceiling/End
Ceiling/End

EAC42003
EAC52003
EAC620018

EAC42006
EAC52006
EAC620021

EAC42009
EAC52009
EAC620021

EAC420012
EAC520012
EAC620024

EXIT LIGHTING

Self-Powered Incandescent
Single Face
Single Face w/Canopy
Double Face w/Canopy

> Dual voltage input
120/277VAC, 60Hz

Self-Powered Fluorescent
Single Face
Single Face w/Canopy
Double Face w/Canopy

WAT TA G E R AT I N G
Lead Calcium Batteries: 7.2W for 2 Hrs.

> Extruded aluminum
housing with mitered
corners and a satin
anodized aluminum
finish
> AC incandescent: two 20W
T6 1/2 intermediate base
lamps
> AC fluorescent: two 7W
compact fluorescent lamps
> DC: two 6V, 3.6W DC
lamps

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: EAC40003

> Universal pattern knockouts on rear for direct
mounting to junction box
Model
Number
See chart above

Accessories (order separately)
Pendant Kit
H2639=Aluminum Finish, 15" Long
Canopy Kit
QE1030SP=Aluminum Finish

> Full length 3/4” stroke
arrow on directional exits
> Red silkscreened lettering
on white phosphorescent,
heat tempered, impact
resistant glass lens

WG10=Wire Guard
WGS11=Wire Guard (for canopy mount without heads)

> Lens installs from side of
fixture

“STAIR” Lens
004380PSSP =
004381PSSP =
004382PSSP =
004383PSSP =

> Louvered downlight

Arrow Left
Arrow Right
Double Arrow
No Arrow

E N E R G Y D ATA

Charge Mode (Fully Discharged Battery) Sealed Lead Calcium Battery
Input Power;
Input Current (Max.): Power Factor:
T.H.D.:
120V
277V
120V
277V
120V 277V
120V 277V
Incandescent Exits - 20W Lamps
52W
52W
.44A
.20A
—
—
—
—
Fluorescent Exits - 7W Lamps
30W
30W
.44A
.20A
—
—
—
—
Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 7.5 Watts in the standby operating mode.

> Line latching, solid-state
voltage limited charger ,
solid-state switching, low
voltage disconnect,
brownout circuit, overload/
short circuit protection,
test switch/power indicator
light
> UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
> City of Chicago Approved

COOPER LIGHTING

97

LIGHTING INVERTERS

SURE-LITES®
DIMENSIONS

DESCRIPTION

MICRO
INVERTER
SERIES
5 0 0 VA - 2 , 0 0 0 VA
HID, Fluorescent and
Incandescent

ON-LINE POWER
I N V E R T E R SYS T E M S

> Choice of 120V or 277VAC,
60Hz; other voltages
available, Consult Cooper
Lighting Representative.
> Available from 500 to 2000
Watts (Field upgradeable)
> Single Phase
> Formed 16 gauge steel
housing is finished in a
durable powder coat finish

The Sure-Lites Micro Series
fast transfer inverter is a
lightweight, compact unit
that takes the place of larger
cabinets when space is at a
premium. The new modular
design allows the Micro
Series inverter to be configured to meet varying KW
requirements from 500W to
2000W. The Micro can be
configured at the factory to
meet the specified job load
requirements or it can be
field configured at the job
site when an upgrade or
downgrade in load capacity
is needed. In addition, the
versatility of the modular
design allows the individual
inverter and battery cabinets
to be mounted on the floor
or wall, side by side, or
stacked when mounting
space is at a premium. The
Micro Series individual
inverter and individual battery cabinets are only 26"W
x 10"H x 10"D providing the
smallest inverter footprint in
the industry. The Micro
Series inverter is UL924 listed and meets NFPA 101
requirements providing the
full 90 minutes of illumination for emergency egress
lighting.

> Small footprint, lightweight size allows for
wall and floor mounting

26”
[660mm]

10”
[254mm]

INVERTER MODULE
26”
[660mm]

B AT T E R Y M O D U L E
10”
[254mm]

10”
[254mm]

S P E C I F I C AT I O N D ATA

Input Voltage
Input Frequency
Synchronizing Slew Rate
Input Protection
Output Voltage
Current Crest Factor
Voltage THD
Output Frequency
Inverter Overload
Output Voltage Regulation
Output Protection
Battery
Environmental
Altitude
Operating Temp.
Storage Temp.
Relative Humidity

120 or 277 VAC, Two wire plus ground, +10/-15%
60Hz, ±3Hz
1Hz per second
Input Circuit Breaker
120 or 277 VAC, Three Wire
2.8 = peak/rms
<3% THD for Linear Load
60 Hz. ±0.05Hz Crystal Controlled
115% for 5 minutes
±3% for ±25% load step change
(1) Output Circuit Breaker
Sealed Lead Calcium VRLA
48 VDC for all models
<10,000 feet without derating
20˚ to +30˚C
-20° to 70°C (Electronics Only)
<95% (non-condensing)

> Modular design for ease of
installation when space is
at a premium
L I F E WAY I I M I C R O S E R I E S S Y S T E M PA R T N U M B E R / R AT I N G / M E C H A N I C A L S P E C I F I C AT I O N S

> Self Testing and Diagnostic
with Event, Test and Alarm
logs
> User programmable with
password protection for
alarms and diagnostics
> 98% efficient in standby
mode - no fan needed for
cooling
> Battery, Input and Output
Protection Circuit Breakers
> Front circuit breaker and
fuse access panel for easy
routine maintenance
> Maintenance Free Sealed
Lead Calcium Batteries
> UL 924 Listed, Meets NFPA
101 Requirements
> City of Chicago approved

98

COOPER LIGHTING

Part
Number
CMFT005
CMFT010
CMFT015
CMFT020

Wattage
Rating
500
1000
1500
2000

VA
Rating
500
1000
1500
2000

Input
Voltage
120 or 277
120 or 277
120 or 277
120 or 277

Output
Voltage
120 or 277
120 or 277
120 or 277
120 or 277

Battery Weight
(lbs.)
107
214
321
427

System Weight
(lbs.)
206
335
464
592

Cabinet
H" x W" x D"
10x26x10
10x26x10
10x26x10
10x26x10

O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: CMFT

CMFT
Series
CMFT=Micro
Inverter

VA Rating
005=500
010=1000
015=1500
020=2000

Voltage Input
120
277

Voltage Output
120
277

Options
See page 102 for options

Cabinet
Qty
2
3
4
5

DESCRIPTION

DIMENSIONS

The Sure-Lites Lifeway II
Single Phase inverter is an
interruptible, PWM inverter
type utilizing IGBT technology
with 50ms transfer time.
Should utility power fail, the
Lifeway II Single Phase inverter takes over and provides output power to the critical load.
Its sealed lead calcium batteries will power emergency
lighting circuits for 90 minutes
(UL 924). Other run times and
voltages available.
Consult Cooper Lighting
Representative.

A

Height

Width

A

B

C

47"

30"

25"

LIGHTING INVERTERS

SURE-LITES®

LIFEWAY II
SINGLE PHASE
IPS SERIES

Depth

1 . 5 - 1 6 . 7 K VA
Fluorescent and
Incandescent

C

B

ON-LINE POWER
I N V E R T E R SYS T E M S

S P E C I F I C AT I O N D ATA

Input Voltage
Input Frequency
Input Protection
Input Harmonic Distortion
Input Power Factor
Output Voltage
Static Voltage
Dynamic Voltage
Output Harmonic Distortion
Output Frequency
Load Power Factor
Inverter Overload
Output Protection
Battery
Environmental
Altitude
Operating Temp.

Storage Temp.
Humidity

120 or 277VAC 1-phase 2 wire +10%-15%. Contact factory for all other voltages.
60Hz, ±3%, 50Hz available upon request
Input Circuit Breaker
<10%
0.5 lag/lead
120 or 277VAC 1-phase 2 wire. Contact factory for all other voltages.
Load current change ±2%, battery discharge ±12.5%
±2% for ±25% load step change, ±3% for a 50% load step change, recovery within 3
cycles
<3% THD for linear load
60 Hz. ±0.05Hz during emergency mode
0.5 lag to 0.5 lead
125% for 5 minutes
Optional Distribution Circuit Breakers
10 Year Valve-regulated Sealed Lead Calcium (standard)

> Input 120 or 277VAC
1 phase 2 wire

<10,000 feet without derating
System operates safely from 0° to 40°C (32° to 104°F) up to 95% humidity. UL rating,
20° to 30°C (68° to 86°F), includes battery performance wich can be affected by
temperature. Contact factory for details.
-20° to 70°C (Electronics Only)
<95% (non-condensing)

> User programmable with
password protection

> Custom voltages available
> Electronic and magnetic
ballast compatible
> Generator compatibility
> Forced air cooling only
during emergency
operation, no filters required
> 90 minute runtime standard;
other runtimes available
upon request
> 98% efficient PWM/IGBT
technology with microprocessor control

> Self-Testing and SelfDiagnostic with Event, Test
and Alarm Logs
> RS232 communications port
> UL 924 listed

L I F E WAY I I S I N G L E P H A S E I P S S Y S T E M PA R T N U M B E R / R AT I N G / M E C H A N I C A L S P E C I F I C AT I O N S
Part
Number
IC1
IC2
IC3
IC4
IC5
IC6
IC7
IC8
IC9
IC10

Pwr Rtg Pwr Rtg Effic. Audible
kVA
kW @ full load Noise
%
db@1m
1.5
1.5
98
45
2.25
2.25
98
45
3.0
3.0
98
45
3.75
3.75
98
45
5.0
5.0
98
45
6.0
6.0
98
45
8.0
8.0
98
45
10.0
10.0
98
45
12.5
12.5
98
45
16.7
16.7
98
45

Heat Loss
BTU
75
100
160
200
245
300
400
500
660
840

UPS Cabinet Dimensions
Width
Height
Depth
in/cm
in/cm
in/cm
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64

UPS
Weight
lb/kg
250/114
265/121
295/134
305/139
315/143
350/159
375/171
435/198
465/211
530/241

Battery
Voltage
VDC
48
72
96
120
144
180
240
144
180
240

Battery Battery
Current
Run
Amperes Minutes
39
90
38
90
38
90
37
90
40
90
40
90
39
90
82
90
82
90
80
90

Battery Cabinet Dimensions
Width
Height
Depth
in/cm
in/cm
in/cm
na2
na2
na2
na2
na2
na2
na2
na2
na2
na2
na2
na2
na2
na2
na2
30/77
30/77
30/77
30/77
30/77

47/120
47/120
47/120
47/120
47/120

25/64
25/64
25/64
25/64
25/64

No. of
Total
Total
Battery No. of
System
Cabinets Cabinets Weight (lb/
na2
1
546/249
na2
1
709/323
na2
1
887/403
na2
1
1045/475
na2
1
1203/546
1
2
1670/759
1
2
2087/949
2
3
2631/1195
2
3
3105/1409
2
3
3954/1795

O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : I C 3 1 2 01 2 0

IC
Series
IC=Single
Phase IPS

KVA Rating
1=1.5
2=2.25
3=3.0
4=3.75
5=5.0

6=6.0
7=8.0
8=10.0
9=12.5
10=16.7

Voltage Input
120
277

Voltage Output
120
277

Options
See page 102 for options

COOPER LIGHTING

99

LIGHTING INVERTERS

SURE-LITES®
DESCRIPTION

DIMENSIONS

The Sure-Lites Lifeway II C
Series is a single phase
inverter that provides uninterrupted power. This pulse
width modulated inverter utilizes IGBT technology and has
a 2 millisecond transfer time.
The unit’s operating efficiency
is 98%, well above a typical
fast transfer inverter. The C
Series inverter is UL 924
Listed and meets NFPA 101
requirements by providing 90
minutes of illumination for
emergency egress lighting.
Other run times and voltages
are available. Please consult
your Cooper Lighting
Representative.

LIFEWAY II
SINGLE PHASE
C SERIES
1 . 5 - 1 6 . 7 K VA
HID, Fluorescent and
Incandescent

A

Height

Width

A

B

Depth

C

47"

30"

25"
B

ON-LINE POWER
I N V E R T E R SYS T E M S

C

S P E C I F I C AT I O N D ATA

> Input 120 or 277VAC
1 phase 2 wire
> Custom voltages available
> Electronic and magnetic ballast compatible
> Generator compatibility
> Forced air cooling only during emergency
operation, no filters
required
> 90 minute runtime standard;
other runtimes available
upon request
> 98% efficient PWM/IGBT
technology with microprocessor control
> User programmable with
password protection
> Self-Testing and SelfDiagnostic with Event, Test
and Alarm Logs
> RS232 communications port

Input Voltage
Input Frequency
Input Protection
Input Harmonic Distortion
Input Power Factor
Output Voltage
Static Voltage
Dynamic Voltage
Output Harmonic Distortion
Output Frequency
Load Power Factor
Inverter Overload
Output Protection
Battery
Environmental
Altitude
Operating Temp.

Storage Temp.
Humidity

120 or 277VAC 1-phase 2 wire +10%-15%. Contact factory for all other voltages.
60Hz, ±3%
Input Circuit Breaker
<10%
0.5 lag/lead
120 or 277VAC 1-phase 2 wire. Contact factory for all other voltages.
Load current change ±2%, battery discharge ±12.5%
±2% for ±25% load step change, ±3% for a 50% load step change, recovery within 3
cycles
<3% THD for linear load
60 Hz. ±0.05Hz during emergency mode
0.5 lag to 0.5 lead
125% for 5 minutes
Optional Distribution Circuit Breakers
10 Year Valve-regulated Sealed Lead Calcium (standard)
<10,000 feet without derating
System operates safely from 0° to 40°C (32° to 104°F) up to 95% humidity. UL rating,
20° to 30°C (68° to 86°F), includes battery performance wich can be affected by
temperature. Contact factory for details.
-20° to 70°C (Electronics Only)
<95% (non-condensing)

> UL 924 listed
L I F E WAY I I S I N G L E P H A S E C S Y S T E M PA R T N U M B E R / R AT I N G / M E C H A N I C A L S P E C I F I C AT I O N S
Part
Number
ISC015
ISC022
ISC030
ISC037
ISC048
ISC060
ISC080
ISC100
ISC125
ISC167

Pwr Rtg Pwr Rtg Effic. Audible
kVA
kW @ full load Noise
%
db@1m
1.5
1.5
98
45
2.25
2.25
98
45
3.0
3.0
98
45
3.75
3.75
98
45
4.8
4.8
98
45
6.0
6.0
98
45
8.0
8.0
98
45
10.0
10.0
98
45
12.5
12.5
98
45
16.7
16.7
98
45

Heat Loss
BTU
75
100
160
200
245
300
400
500
660
840

UPS Cabinet Dimensions
Width
Height
Depth
in/cm
in/cm
in/cm
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64

UPS
Weight
lb/kg
250/114
265/121
295/134
305/139
315/143
350/159
375/171
435/198
465/211
530/241

Battery
Voltage
VDC
48
72
96
120
144
180
240
144
180
240

Battery Battery
Current
Run
Amperes Minutes
39
90
38
90
38
90
37
90
40
90
40
90
39
90
82
90
82
90
80
90

Battery Cabinet Dimensions
Width
Height
Depth
in/cm
in/cm
in/cm
2
2
na
na
na2
2
2
na
na
na2
na2
na2
na2
na2
na2
na2
na2
na2
na2
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64

O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : I S C 0 3 7 1 2 01 2 0

ISC
Series
ISC=Single
Phase C

100

COOPER LIGHTING

KVA Rating
015=1.5
022=2.25
030=3.0
037=3.75
048=4.8

060=6.0
080=8.0
100=10.0
125=12.5
167=16.7

Voltage Input
120
277

Voltage Output
120
277

Options
See page 102 for options

No. of
Total
Total
Battery No. of
System
Cabinets Cabinets Weight (lb/kg)
na2
1
546/249
na2
1
709/323
2
na
1
887/403
2
na
1
1045/475
na2
1
1203/546
1
2
1670/759
1
2
2087/949
2
3
2631/1195
2
3
3105/1409
2
3
3954/1795

DESCRIPTION

DIMENSIONS

The Sure-Lites Lifeway II Three
Phase represents the highest
performance in uninterruptible
technology while the transistorized inverter is providing
power protection. Ready for
virtually any emergency with
this stand by power system.
This pulse width modulated
inverter has 2 millisecond
transfer time. The AC in to AC
out operating efficiency is typically 98%, well above a typical
fast transfer inverter. The internal construction of each cabinet consists of an AC to DC
battery charger, DC to AC
inverter.

A

C

B

Height

Models

Width

Depth

A

B

C

C3FT-004 thru 016

47"

30"

25"

C3FT-024 thru 050

72"

44"

31"

C3FT024 thru 050*

72”

48”

31”

Output Harmonic Distortion
Output Frequency
Load Power Factor
Inverter Overload
Output Protection
Battery
Environmental
Altitude
Operating Temp.
Storage Temp.
Humidity

LIFEWAY II
THREE PHASE
SERIES
4 . 8 - 5 0 k VA
HID, Fluorescent and
Incandescent
ON-LINE POWER
I N V E R T E R SYS T E M S

S P E C I F I C AT I O N D ATA

Input Voltage
Input Frequency
Input Protection
Input Harmonic Distortion
Input Power Factor
Output Voltage
Static Voltage
Dynamic Voltage

LIGHTING INVERTERS

SURE-LITES®

120/208 or 277/480VAC 3-phase 4 wire +1%-15% (Wye configuration)
60Hz, ±3%, 50Hz available upon request
Input Circuit Breaker
<10%
.5 lag/lead
120/208 or 277/480VAC 3-phase 4 wire (Wye or Delta configuration)
Load current change ±4%, battery discharge ±4%
±3% for ±25% load step change, ±6% for a 50% load step change, recovery within
3 cycles
<3% THD for linear load
60 Hz. ±0.05Hz during emergency mode
.5 lag to .5 lead
115% for 5 minutes
Output Circuit Breaker (Optional)
10 Year Valve Regulated Sealed Lead Calcium

> Choice of 120/208 VAC or
277/480 VAC, 60 Hz; other
voltages available, consult
Cooper Lighting
Representative
> Three Phase, WYE or
DELTA configurations
> 98% efficiency
> Formed steel cabinet and
doors are finished in a
durable powder coat
> Acoustically Quiet
> PWM/GBT Technology
> Sine wave output
> 80db transverse mode
noise attenuation
> 120db common mode
noise attenuation

<10,000 feet without derating
20˚ to +30˚C
-20° to 70°C (Electronics Only)
<95% (non-condensing)

> Battery circuit breaker on
24 kVA and up
> RS-232 Communication
> UL 924 Listed

L I F E WAY I I T H R E E P H A S E S Y S T E M PA R T N U M B E R / R AT I N G / M E C H A N I C A L S P E C I F I C AT I O N S
Part
Number
C3FT004
C3FT006
C3FT008
C3FT010
C3FT012
C3FT016
C3FT024
C3FT033
C3FT040
C3FT050

Pwr Rtg Pwr Rtg Effic. Audible
kVA
kW @ full load Noise
%
db @/m
4.8
4.8
97
45
6.0
6.0
97
45
8.0
8.0
97
45
10.0
10.0
97
45
12.5
12.5
97
45
16.7
16.7
97
45
24.0
24.0
97
45
33.0
33.0
97
45
40.0
40.0
97
45
50.0
50.0
97
45

Heat Loss
BTU
326
408
544
680
850
1136
1632
2244
2720
3400

UPS Cabinet Dimensions
Width
Height
Depth
in/cm
in/cm
in/cm
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
44/112
72/183
31/79
44/112
72/183
31/79
44/112
72/183
31/79
44/112
72/183
31/79

UPS
Weight
lb/kg
535/243
535/243
535/243
639/290
639/290
639/290
1250/567
1250/567
1450/658
1450/658

Battery
Voltage
VDC
144
180
240
144
180
240
240
240
240
240

Battery Battery
Current
Run
Amperes Minutes
39
90
39
90
39
90
81
90
81
90
81
90
117
90
160
90
194
90
243
90

Battery Cabinet Dimensions
Width
Height
Depth
in/cm
in/cm
in/cm
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
30/77
47/120
25/64
48/122 72/183
31/79
48/122 72/183
31/79
48/122 72/183
31/79
48/122 72/183
31/79

No. of
Total
Total
Battery No. of
System
Cabinets Cabinets Weight (lb/kg)
1
2
1633/741
1
2
1855/842
1
2
2247/1020
2
3
2835/1286
2
3
3279/1488
2
3
4063/1843
1
2
6390/2899
2
3
8630/3915
2
3
10150/4604
2
3
11980/5434

O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : C 3 F T 0 0 4 1 2 01 2 0

C3FT
Series
C3FT=Three
Phase

KVA Rating
004=4.8
006=6.0
008=8.0
010=10.0
012=12.5

016=16.7
024=24.0
033=33.0
040=40.0
050=50.0

Voltage Input
120=120/208
277=277/480

Voltage Output
120=120/208
277=277/480

Options
See page 102 for options

* Battery Cabinets

COOPER LIGHTING

101

LIGHTING INVERTERS

SURE-LITES®
INVERTERS - FACTORY OPTIONS
Output Circuit Breakers

W X YY ZZ
W = Output -

B = Normally On

YY = Amp Rating (10, 20)

N = Normally Off
A = 120 Volt
X = Pole -

B = 208 Volt

ZZ = Qty 01-12

C = 240 Volt

Micro Inverter = 3 max. without trip alarm
1 with trip alarm

D = 277 Volt

Micro Inverter Series-CMFT

IPS Series - IC

C Series - ISC

Three Phase Series - C3FT

102

COOPER LIGHTING

T

Circuit Breaker Trip Alarm

R

RS-232 Diagnostic Interface (DB9)

S

Summary Dry Contacts (Form “C”)

N

Normally Off Output

A

Remote Summary Alarm

M

Remote Meter Panel

A

Auto Dialer/Pager

C

Normally Off Dry Contact (Inverter On)

D

Dimmer Bypass Relay

FAX

Fax/Modem (utility, inverter & output failure notification)

F

Battery Charger Upgrade (12 Hour Recharge)

G

20 Year Premium Sealed Lead Calcium Battery

M

Maintenance Bypass Switch (MB4B) (External or Internal)

R

Remote Meter Panel

RSAP

Remote Summary Alarm Panel

S

Summary Dry Contacts (Form “C”)

T

Output Circuit Breaker Trip Alarm

V

Variable Time Delay Circuit

Z

Zone Monitoring (16 amps Maximum)

A

Auto Dialer/Pager

F

Battery Charger Upgrade (12 Hour Recharge)

FAX

Fax/Modem (utility, inverter & output failure notification)

G

20 Year Premium Sealed Lead Calcium Battery

M

Maintenance Bypass Switch (MB4B) (External or Internal)

N

Normally-Off Output Circuit

RMP

Remote Meter Panel

RSAP

Remote Summary Alarm Panel

S

Summary Dry Contacts (Form “C”)

T

Output Circuit Breaker Trip Alarm

A

Auto Dialer/Pager

F

Battery Charger Upgrade (12 Hour Recharge)

FAX

Fax/Modem (utility, inverter & output failure notification)

G

20 Year Premium Sealed Lead Calcium Battery

N1

Normally-Off Output Circuit, single phase

N3

Normally-Off Output Circuit, three phase

RMP

Remote Meter Panel

RSAP

Remote Summary Alarm Panel

S

Summary Dry Contacts (Form “C”)

T

Output Circuit Breaker Trip Alarm
- output trip alarm is not available on 24k-50k systems

NI-CAD

Nickel-Cadmium Battery

* Consult factory for additional options and available accessories.

REFERENCE-FACTORY OPTIONS
EXIT LIGHTING OPTIONS

S P E C I F I C AT I O N F E AT U R E S – P O LY C A R B O N A T E L E N S

S P E C I F I C AT I O N F E AT U R E S – F L A S H E R

Impact-resistant lens provides high degree of protection
from breakage.

Flashes the DC lamps of exits in the emergency mode.
S P E C I F I C AT I O N F E AT U R E S – F L A S H E R / B U Z Z E R

S P E C I F I C AT I O N F E AT U R E S – M E T A L H E A D S

The metal housing is made of corrosion resistant, 22
gauge spun aluminum with a baked acrylic enamel finish
to match fixture color.
Die cast aluminum swivel assembly has 80° aiming
adjustment from vertical.

Flashes the DC lamps of exits in emergency mode in combination with an
audible signal.

Factory Options

EMERGENCY LIGHTING OPTIONS

REFERENCE >

SURE-LITES®

S P E C I F I C AT I O N F E AT U R E S – T A M P E R P R O O F S C R E W S

#8-32 Button Head Stainless Steel Screws
Centerpin Torx tamper resistant type

S P E C I F I C AT I O N F E AT U R E S – A M M E T E R

Qty. 4 per fixture

Ammeter provides an easily interpreted display of the
charger current level.

Requires Sure-Lites No. VRSD Screwdriver

S P E C I F I C AT I O N F E AT U R E S – T I M E D E L AY M O N I T O R

Time delay monitor keeps the emergency lamps on after
AC power has been restored for a predetermined period
of time (15 minutes is standard); allows sufficient time for
HID fixtures to resume normal illumination.

S P E C I F I C AT I O N F E AT U R E S – V A N D A L S H I E L D A N D T A M P E R P R O O F
SCREWS

1/8" thick clear polycarbonate
Vandal Shield is L-shaped on single face CAX Series Exits, U-shaped on
double face CAR Series Exits
(4) #6-32 Flat Head Stainless Steel Screws Centerpin Torx® tamper resistant
type

S P E C I F I C AT I O N F E AT U R E S – T H E R M A L H E A T E R

The 10 Watt Thermal Heater raises the temperature in the
battery compartment of the unit when used in extreme
cold conditions. The thermal heater operates at 110 VAC
and is UL Listed.
S P E C I F I C AT I O N F E AT U R E S – V O L T M E T E R

Factory installed voltmeter provides an easily interpreted
display of the battery voltage.

S P E C I F I C AT I O N F E AT U R E S – D C F I R E A L A R M I N T E R F A C E F O R
EXITS

Fire Alarm Interface Option allows AC incandescent or LED lamps to flash
in non-emergency mode and the DC lamps to flash in an emergency mode
when a fire alarm signal is received by the exit fixture from a fire alarm
panel.
S P E C I F I C AT I O N F E AT U R E S – A C O N LY F I R E A L A R M I N T E R F A C E
FOR EXITS

Fire Alarm Interface Option allows AC incandescent or LED lamps to flash
when a fire alarm signal is received by the exit fixture from a fire alarm
panel.

O R D E R I N G I N F O R M AT I O N – E M E R G E N C Y L I G H T I N G
1
UNIT OPTIONS
Catalog
Number
Suffix

Description

PCL
MH
A
TDM
TH
V

Polycarbonate Lens
Metal Heads
Ammeter
Time Delay Monitor
Thermal Heater
Voltmeter

1See

O R D E R I N G I N F O R M AT I O N – E X I T L I G H T I N G O P T I O N S 1
Catalog
Number
Suffix

Description

70
20
30
65
85
90
95

Nickel Cadmium Battery
Flasher
Flasher/Buzzer
Tamperproof Screws
Vandal Shield with Tamperproof Screws
DC Fire Alarm Interface
AC Only Fire Alarm Interface

individual product ordering information for availability.

COOPER LIGHTING

103

Self Diagnostic

TECHNICAL INFORMATION >

SURE-LITES®
TECHNICAL INFORMATION - SELF DIAGNOSTIC
DESCRIPTION
ELECTRONIC

TEST PERFORMANCE

I N S TA L L AT I O N / O P E R AT I O N

Microprocessor Based System

Checks battery charger, battery
voltage, lamps

No special provisions required
for installation

A 30-second full functional test is
performed every 30 days

Lamp loads are automatically
calibrated after battery initially
reaches a full charge.

A 90-minute full function/battery
capacity test is performed every
6 months

Version 1

System diagnoses failure to the
defective component level (battery, charger PC board, lamp) and
provides a visual diagnostic display through the LED indicator
light

CODE COMPLIANCE

UL 924 Listed
Life Safety NFPA 101
NEC/OSHA
Most State and Local Codes

Battery charge indicator differentiates high charge and standby
charge mode

Version 2
WatchGuard EMS SD
(Electronic Monitoring System)

Self Diagnostic
Fa c to r y I n s t a l l e d
Emergency Lighting
Exit Lighting

• The WatchGuard EMS
self-diagnostics option from
Sure-Lites sets the standard
for automatic stand-alone
testing of emergency
lighting units and battery
powered exits
• The Solid-State microprocessor-based system
has the ability to accurately
diagnose failures to the
component level plus it
incorporates all of the
standard electronic features
that sets Sure-Lites apart
from its competition
• All testing required by the
NFPA 101 Life Safety Code
is performed automatically.
WatchGuard EMS even
automatically calibrates
itself in the field, reducing
installation labor and
eliminating manual
calibration errors
• Ultrasensitive detection
circuitry can sense lamp
failure in a circuit, as well
as slight variations in battery
and battery charger
performance
• UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA, most
state and local codes

104

COOPER LIGHTING

D I A G N O S T I C I N D I C AT O R S - V E R S I O N 1
INDICATOR

COLOR

MEANING

 (STEADY)

GREEN

FLOAT CHARGE

ACTION
BATTERY FULLY CHARGED

 (PULSE)

GREEN

HIGH CHARGE

BATTERY BEING CHARGED AT HIGH RATE

 (PULSE)

RED

BATTERY CAPACITY FAILURE

TURN OFF AC, REPLACE BATTERY

-

RED

BATTERY OPEN

TURN OFF AC, CHECK BATTERY CONNECTIONS

--

RED

TRANSFORMER FAILURE

TURN OFF AC, REPLACE TRANSFORMER

---

RED

BATTERY CHARGER FAILURE

TURN OFF AC, REPLACE PC BOARD

 (PULSE)

YELLOW

EMERGENCY LAMP FAILURE

REPLACE EMERGENCY LAMP

-

YELLOW

EMER. LAMP SHORT/OVERLOAD

CHECK LAMP LOAD, POSSIBLE SHORT

( O N E X I T S W I T H L I G H T I N G H E A D S O N LY )
--

YELLOW

EXIT LAMP FAILURE

REPLACE EXIT LAMP

---

YELLOW

EXIT LAMP SHORT/OVERLOAD

CHECK LAMP LOAD, POSSIBLE SHORT

D I A G N O S T I C I N D I C AT O R S - V E R S I O N 2
INDICATOR

COLOR

MEANING

 (STEADY)

RED

FLOAT CHARGE

ACTION
BATTERY FULLY CHARGED

 (PULSE)

RED

HIGH CHARGE

BATTERY BEING CHARGED AT HIGH RATE

-

RED

BATTERY FAILURE

TURN OFF AC, REPLACE BATTERY

--

RED

CIRCUIT FAILURE

TURN OFF AC, REPLACE PC BOARD

---

RED

LAMP FAILURE

TURN OFF AC, REPLACE PC LAMP

O R D E R I N G I N F O R M AT I O N N O N - S TA N D A R D L A M P S

DESCRIPTION

S A M P L E N U M B E R : X R 11 3 1 3

This information is provided
to help you select non-standard
lamps for specific applications. In
ordering Sure-Lites emergency
lighting units, a standard lamp will
be provided unless a particular
lamp is specified by Lamp No.

XR11
Model Number

3

13

No. of
Lamps/
Heads

TECHNICAL
INFORMATION
LAMP
SPECIFICATIONS

Make sure that the unit’s battery
wattage is sufficient for powering
non-standard lamps.

Lamp No.
29-13

Lamp Specifications

A standard XR11 is supplied with
two 6 volt, 9 watt incandescent
heads.
To order a modified XR11 unit with
three heads using 6 volt, 18 watt
incandescent sealed beam lamps,
the appropriate number of heads
and Lamp No. must be included as
an Order Suffix.

Lamp
N o.
L010777
29-139
29-146
29-121
29-12
29-37
29-30
29-75
29-88
29-14
29-03
29-114
29-143
29-84
29-40
29-36
29-140
29-15
29-66
29-39
29-17
29-13
29-137
29-18
29-09
29-53
29-16
29-86
29-141
29-132
29-45
29-26
29-79
29-24
29-54
29-19
29-142
29-08
29-55
29-126
29-134
29-144
29-135
29-124
29-80
Z-67
29-125
29-130
29-129
Z-7

Vo l t s
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
120
120
120
120
130
145
120

Wa tt s
4.8
5
5.4
5.4
6
6
6.6
7.2
7.2
8
8
8
9
9
10
10
12
12
12
12
13
18
20
20
25
7.5
8
9
12
12
12
12
12
13
18
18
20
25
28
30
37.5
50
50
5
6
7
8
7
15
20

Ty p e
Halogen Bi-Pin T21/4
MR16 Bi-Pin Base
Krypton Wedge Base
Incandescent Wedge Base
Halogen Bi-Pin T21/4
Halogen Sealed Beam
Incandescent DC Bayonet Base
Incandescent Sealed Beam
Incandescent Wedge Base
Halogen Sealed Beam
Incandescent Sealed Beam
Halogen Bi-Pin T21/4
MR16 Bi-Pin Base
Incandescent Wedge Base
Halogen Bi-Pin T21/4
Halogen Sealed Beam
MR16 Bi-Pin Base
Halogen Sealed Beam
Halogen Bi-Pin T21/4
Incandescent Sealed Beam
Incandescent DC Bayonet Base
Incandescent Sealed Beam
Halogen Bi-Pin T21/4
Halogen Sealed Beam
Incandescent Sealed Beam
Incandescent DC Bayonet Base
Halogen Sealed Beam
Incandescent Wedge Base
MR16 Bi-Pin Base
Incandescent Wedge Base
Halogen Bi-Pin T21/4
Incandescent Sealed Beam
Halogen Sealed Beam
Incandescent DC Bayonet Base
Incandescent DC Bayonet Base
Incandescent Sealed Beam
MR16 Bi-Pin Base
Incandescent Sealed Beam
Incandescent DC Bayonet Base
Incandescent Sealed Beam
Halogen Sealed Beam
MR16 Bi-Pin Base
Halogen Sealed Beam
Compact Fluorescent Twin Tube, G23 Base
F6T5 Fluorescent Miniature Bi-Pin Cool White
Compact Fluorescent Twin Tube, G23 Base
F8T5 Fluorescent Miniature Bi-Pin Cool White
Incandescent Candelabra Base, 7C7
Incandescent Candelabra Base, 15T6
Incandescent Intermediate Base T6 1/2

TECHNICAL INFORMATION >

SURE-LITES®

Initial
Lumens
69
45
90
68
113
107
75
95
101
109
108
163
90
151
201
191
145
302
234
137
189
158
402
382
318
75
155
138
145
151
277
177
266
189
264
213
300
327
402
390
825
850
1100
250
295
390
400
46
102
92

COOPER LIGHTING

105

Wire Selection Char t

TECHNICAL INFORMATION >

SURE-LITES®
TECHNICAL INFORMATION - WIRE SELECTION CHART
W I R E S E L E C T I O N C H A R T / V O LT A G E D R O P T A B L E
6 Vo l t s M a x i m u m Vo l t a g e D r o p 5 % a s p r e s c ri b e d b y N a t i o n a l E l e c t ri c a l C o d e
Wiring Length
Wire
Size
#12
#10
#8
#6

Watts
6
89
141
225
358

8
67
106
169
268

10
53
85
135
215

12
45
71
113
179

16
33
53
84
134

18
30
47
75
120

20
27
42
68
107

24
22
35
56
89

25
21
32
54
86

28
19
30
48
77

35
15
24
39
62

44
12
19
31
49

Constant Value
534
849
1350
2148

50
11
17
27
43

75
8
11
18
29

100
6
9
14
22

150
4
6
9
15

200

250

7
11

9

150
14
23
36
57

200
10
17
27
43

250
8
14
21
34

300

Constant Value
2137
3397
5403
8590

1 2 Vo l t s M a x i m u m Vo l t a g e D r o p 5 % a s p r e s c ri b e d b y N a t i o n a l E l e c t ri c a l C o d e
Wiring Run Length
Wire
Size
#12
#10
#8
#6

Watts
8
267
425
675
1073

12
178
283
450
716

13
165
260
415
660

16
134
212
338
537

18
110
190
300
475

24
89
142
225
358

25
85
136
215
340

28
76
121
193
307

35
61
97
154
245

FORMULAS

CM=22xWxL
.05xE2

44
49
77
123
195

50
42
68
108
170

75
29
45
72
114

100
21
34
54
86

11
18
28

CIRCULAR MILL CHART

L= CMx.05xE2
22xW

The above tables show maximum wire lengths based on
system voltage, wire size, and
total wattage on a given wire
run. To determine the maximum wire run length or total
wattage on a given wire run,
divide the known value into
the constant value shown on
the above charts for the
appropriate wire size and system voltage specified.

106

13
41
65
110
165

COOPER LIGHTING

CM=Wire size in circular mils
W=Emergency loads in watts
L=Length of circuit in feet
E=Line voltage
.22=Formula Constant
.05=Factor for maximum
allowable voltage drop

Example: Four 9W remote
heads (36W total) are to be
operated on a 12V system
using a single #10 wire run.
The maximum wire run
length is:
Constant Value = 3397= 94 ft.
known value
36

AWG
12
10
8
6

AMP CAPACITY
20
25
30
50

Example: In the system
described in the example (left),
the four 9W remote heads will
be uniformly spaced along the
wire run. The wire run can be
increased to:
94ft. x 1.6 (multiplier) = 150 ft.

If loads are uniformly spaced
along a given wire run (equal
wattages, equal distances),
the determined wire length
can be increased by the following multipliers:
Number of
Fixtures (n)
Multiplier

2

3

4

1.33 1.5 1.6

CM
6,530
10,380
16,510
26,250

5+
2n
n +1

SURE-LITES®

NFPA 101 (2006)

7.8.2 Sources of Illumination.
7.8.2.1* Illumination of means of egress shall be from a source
considered reliable by the authority having jurisdiction.
7.8.2.2 Battery-operated electric lights and other types of portable
lamps or lanterns shall not be used for primary illumination of means
of egress. Batteryoperated electric lights shall be permitted to be
used as an emergency source to the extent permitted under Section
7.9.
7.9 Emergency Lighting.
7.9.1 General.
7.9.1.1* Emergency lighting facilities for means of egress shall be
provided in accordance with Section 7.9 for the following:
(1) Buildings or structures where required in Chapter 11 through
Chapter 42
(2) Underground and limited access structures as addressed in
Section 11.7
(3) High-rise buildings as required by other sections of this Code
(4) Doors equipped with delayed-egress locks
(5) Stair shaft and vestibule of smokeproof enclosures, for which the
following also apply:
(a) The stair shaft and vestibule shall be permitted to include a
standby generator that is installed for the smokeproof
enclosure mechanical ventilation equipment.
(b) The standby generator shall be permitted to be used for the
stair shaft and vestibule emergency lighting power supply.

(6) New access-controlled egress doors in accordance with 7.2.1.6.2.
7.9.1.2 For the purposes of 7.9.1.1, exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways
leading to an exit. For the purposes of 7.9.1.1, exit discharge shall
include only designated stairs, ramps, aisles, walkways, and escalators leading to a public way.
7.9.1.3 Where maintenance of illumination depends on changing
from one energy source to another, a delay of not more than 10 seconds shall be permitted.
7.9.2 Performance of System.
7.9.2.1* Emergency illumination shall be provided for not less than 1
1/2 hours in the event of failure of normal lighting. Emergency lighting facilities shall be arranged to provide initial illumination that is
not less than an average of 1 ft-candle (10.8 lux) and, at any point, not
less than 0.1 ft-candle (1.1 lux), measured along the path of egress at
floor level. Illumination levels shall be permitted to decline to not less
than an average of 0.6 ft-candle (6.5 lux) and, at any point, not less
than 0.06 ft-candle (.65 lux) at the end of the 1 1/2 hours. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be
exceeded.
7.9.2.2 New emergency power systems for emergency lighting shall
be at least Type 10, Class 1.5, Level 1, in accordance with NFPA 110,
Standard for Emergency and Standby Power Systems.
7.9.2.3* The emergency lighting system shall be arranged to provide
the required illumination automatically in the event of any interruption of normal lighting due to any of the following:
(1) Failure of a public utility or other outside electrical power
supply
(2) Opening of a circuit breaker or fuse
(3) Manual act(s), including accidental opening of a switch
controlling normal lighting facilities
7.9.2.4 Emergency generators providing power to emergency lighting
systems shall be installed, tested, and maintained in accordance with
NFPA 110, Standard for Emergency and Standby Power Systems.
Stored electrical energy systems, where required in this Code, shall
be installed and tested in accordance with NFPA 111, Standard on
Stored Electrical Energy Emergency and Standby Power Systems.
7.9.2.5 Unit equipment and battery systems for emergency luminaires shall be listed to UL 924, Standard for Emergency Lighting and
Power Equipment.
7.9.2.6* Existing battery-operated emergency lights shall use only
reliable types of rechargeable batteries provided with suitable facilities for maintaining them in properly charged condition. Batteries
used in such lights or units shall be approved for their intended use
and shall comply with NFPA 70, National Electrical Code.
7.9.2.7 The emergency lighting system shall be either continuously in
operation or shall be capable of repeated automatic operation without manual intervention.

Life Safety Code: National Fire Protection Association

7.8 Illumination of Means of Egress.
7.8.1 General
7.8.1.1* Illumination of means of egress shall be provided in accordance with Section 7.8 for every building and structure where
required in Chapter 11 through Chapter 42. For the purposes of this
requirement, exit access shall include only designated stairs, aisles,
corridors, ramps, escalators, and passageways leading to an exit. For
the purposes of this requirement, exit discharge shall include only
designated stairs, aisles, corridors, ramps, escalators, walkways, and
exit passage ways leading to a public way.
7.8.1.2 Illumination of means of egress shall be continuous during the
time that the conditions of occupancy require that the means of
egress be available for use, unless otherwise provided in 7.8.1.2.2.
7.8.1.2.1 Artificial lighting shall be employed at such locations and for
such periods of time as are necessary to maintain the illumination to
the minimum criteria values herein specified.
7.8.1.2.2 Automatic, motion sensor-type lighting switches shall be
permitted within the means of egress, provided that the switch controllers are equipped for fail-safe operation, the illumination timers
are set for a minimum 15-minute duration, and the motion sensor is
activated by any occupant movement in the area served by the
lighting units.
7.8.1.3* The floors and other walking surfaces within an exit and
within the portions of the exit access and exit discharge designated
in 7.8.1.1 shall be illuminated as follows:
(1) During conditions of stair use, the minimum illumination for new
stairs shall be at least 10 ft-candle (108 lux), measured at the
walking surfaces.
(2) The minimum illumination for floors and walking surfaces, other
than new stairs during conditions of stair use, shall be to values
of at least 1 ft-candle (10.8 lux), measured at the floor.
(3) In assembly occupancies, the illumination of the floors of exit
access shall be at least 0.2 ft-candle (2.2 lux) during periods of
performances or projections involving directed light.
(4) * The minimum illumination requirements shall not apply where
operations or processes require low lighting levels.
7.8.1.4* Required illumination shall be arranged so that the failure of
any single lighting unit does not result in an illumination level of less
than 0.2 ft-candle (2.2 lux) in any designated area.
7.8.1.5 The equipment or units installed to meet the requirements of
Section 7.10 also shall be permitted to serve the function of illumination of means of egress, provided that all requirements of Section 7.8
for such illumination are met.

TECHNICAL INFORMATION >

TECHNICAL INFORMATION LIFE SAFETY CODE®: NATIONAL FIRE PROTECTION ASSOC.

7.9.3 Periodic Testing of Emergency Lighting Equipment.
7.9.3.1 Required emergency lighting systems shall be tested in accordance with one of the three options offered by 7.9.3.1.1, 7.9.3.1.2, or
7.9.3.1.3.
7.9.3.1.1 Testing of required emergency lighting systems shall be
permitted to be conducted as follows:
(1) Functional testing shall be conducted at 30-day intervals for
not less than 30 seconds.
(2) Functional testing shall be conducted annually for not less
than 1 1/2 hours if the emergency lighting system is battery
powered.
(3) The emergency lighting equipment shall be fully operational
for the duration of the tests required by 7.9.3.1.1 (1) and
7.9.3.1.1 (2).
(4) Written records of visual inspections and tests shall be kept by
the owner for inspection by the authority having jurisdiction.
7.9.3.1.2 Testing of required emergency lighting systems shall be
permitted to be conducted as follows:
(1) Self-testing/self-diagnostic battery-operated emergency
lighting equipment shall be provided.

Reprinted with permission from NFPA 101®, Life Safety Code®, Copyright© 2006, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not
the complete and official position of the National Fire Protection Association on the reference subject which is represented only by the standard in its entirety.

COOPER LIGHTING

107

Life Safety Code: National Fire Protection Association

TECHNICAL INFORMATION >
108

SURE-LITES®

TECHNICAL INFORMATION LIFE SAFETY CODE®: NATIONAL FIRE PROTECTION ASSOC.

(2) Self-testing/self-diagnostic battery-operated emergency
lighting equipment shall automatically perform not less than
once every 30 days a test for not less than 30 seconds and a
diagnostic routine.
(3) Self-testing/self-diagnostic battery-operated emergency
lighting equipment shall indicate failures by a status indicator.
(4) A visual inspection shall be performed at intervals not
exceeding 30 days.
(5) Functional testing shall be conducted annually for not less
than 1 1/2 hours.
(6) Self-testing/self-diagnostic battery-operated emergency
lighting equipment shall be fully operational for the duration
of the 1 1/2 hour test.
(7) Written records of visual inspections and tests shall be kept by
the owner for inspection by the authority having jurisdiction.
7.9.3.1.3 Testing of required emergency lighting systems shall be
permitted to be conducted as follows:
(1) Computer-based, self-testing/self-diagnostic battery-operated
emergency lighting equipment shall be provided.
(2) The emergency lighting equipment shall automatically per
form not less than once every 30 days a test for not less than
30 seconds and a diagnostic routine.
(3) The emergency lighting equipment shall automatically per
form annually a test for not less than 11/2 hours.
(4) The emergency lighting equipment shall be fully operational
for the duration of the tests required by 7.9.3.1.3(2) and
7.9.3.1.3(3).
(5) The computer-based system shall be capable of providing a
report of the history of tests and failures at all times.
7.10 Marking of Means of Egress.
7.10.1 General.
7.10.1.1 Where Required. Means of egress shall be marked in
accordance with Section 7.10 where required in Chapter 11 through
Chapter 42.
7.10.1.2* Exits. Exits, other than main exterior exit doors that obviously and clearly are identifiable as exits, shall be marked by an
approved sign that is readily visible from any direction of exit access.
7.10.1.3 Exit Stair Door Tactile Signage. Tactile signage shall be provided to meet the following criteria, unless otherwise provided in
7.10.1.4:
(1) Tactile signage shall be located at each exit door requiring an
exit sign.
(2) Tactile signage shall read as follows: EXIT
(3) Tactile signage shall comply with ICC/ANSI A117.1, American
National Standard for Accessible and Usable Buildings and
Facilities.
7.10.1.4 Existing Exemption. The requirements of 7.10.1.3 shall not
apply to existing buildings, provided that the occupancy classification does not change.
7.10.1.5 Exit Access.
7.10.1.5.1 Access to exits shall be marked by approved, readily visible
signs in all cases where the exit or way to reach the exit is not readily
apparent to the occupants.
7.10.1.5.2* New sign placement shall be such that no point in an exit
access corridor is in excess of the rated viewing distance or 100 ft
(30 m), whichever is less, from the nearest sign.
7.10.1.6* Floor Proximity Exit Signs. Where floor proximity exit signs
are required in Chapter 11 through Chapter 42, such signs shall be
located near the floor level in addition to those signs required for
doors or corridors. The signs shall be illuminated in accordance with
7.10.5. Externally illuminated signs shall be sized in accordance with
7.10.6.1. The bottom of the sign shall be not less than 6 in. (150 mm),
but not more than 18 in. (455 mm), above the floor. For exit doors,
the sign shall be mounted on the door or adjacent to the door, with
the nearest edge of the sign within 4 in. (100 mm) of the door frame.
7.10.1.7* Floor Proximity Egress Path Marking. Where floor proximity
egress path marking is required in Chapter 11 through Chapter 42, a
listed and approved floor proximity egress path marking system that

COOPER LIGHTING

is internally illuminated shall be installed within 18 in. (455 mm) of
the floor. The system shall provide a visible delineation of the path of
travel along the designated exit access and shall be essentially continuous, except as interrupted by doorways, hallways, corridors, or
other such architectural features. The system shall operate continuously or at any time the building fire alarm system is activated. The
activation, duration, and continuity of operation of the system shall
be accordance with 7.9.2. The system shall be maintained in accordance with the product manufacturing listing.
7.10.1.8* Visibility. Every sign required in Section 7.10 shall be located
and of such size, distinctive color, and design that it is readily visible
and shall provide contrast with decorations, interior finish, or other
signs. No decorations, furnishings, or equipment that impairs visibility of a sign shall be permitted. No brightly illuminated sign (for other
than exit purposes), display, or object in or near the line of vision of
the required exit sign that could detract attention from the exit sign
shall be permitted.
7.10.1.9 Mounting Location. The bottom of new egress markings shall
be located at a vertical distance of not more than 6 ft 8 in. (2030 mm)
above the top edge of the egress opening intended for designation
by that marking. Egress markings shall be located at a horizontal distance of not more than the required width of the egress opening, as
measured from the edge of the egress opening intended for designation by that marking to the nearest edge of the marking.
7.10.2* Directional Signs. A sign complying with 7.10.3 with a
directional indicator showing the direction of travel shall be placed in
every location where the direction of travel to reach the nearest exit
is not apparent.
7.10.3* Sign Legend.
7.10.3.1 Signs required by 7.10.1 and 7.10.2 shall read as follows in
plainly legible letters, or other appropriate wording shall be used:
EXIT
7.10.3.2* Where approved by the authority having jurisdiction, pictograms shall be permitted.
7.10.4* Power Source. Where emergency lighting facilities are
required by the applicable provisions of Chapter 11 through Chapter
42 for individual occupancies, the signs, other than approved selfluminous signs and listed photoluminescent signs in accordance
with 7.10.7.2, shall be illuminated by the emergency lighting facilities. The level of illumination of the signs shall be in accordance with
7.10.6.3 or 7.10.7 for the required emergency lighting duration as
specified in 7.9.2.1. However, the level of illumination shall be permitted to decline to 60 percent at the end of the emergency lighting
duration.
7.10.5 Illumination of Signs.
7.10.5.1* General. Every sign required by 7.10.1.2, 7.10.1.5, or
7.10.8.1, other than where operations or processes require low lighting levels, shall be suitably illuminated by a reliable light source.
Externally and internally illuminated signs shall be legible in both the
normal and emergency lighting mode.
7.10.5.2* Continuous Illumination.
7.10.5.2.1 Every sign required to be illuminated by 7.10.6.3, 7.10.7,
and 7.10.8.1 shall be continuously illuminated as required under the
provisions of Section 7.8, unless otherwise provided in 7.10.5.2.2.
7.10.5.2.2* Illumination for signs shall be permitted to flash on and off
upon activation of the fire alarm system.
7.10.6 Externally Illuminated Signs.
7.10.6.1* Size of Signs.
7.10.6.1.1 Externally illuminated signs required by 7.10.1 and 7.10.2,
other than approved existing signs, unless otherwise provided in
7.10.6.1.2, shall read EXIT, or shall use other appropriate wording in
plainly legible letters sized as follows:
(1) For new signs, the letters shall be not less than 6 in. (150 mm)
high, with the principal strokes of letters not less than 3/4 in.
(19 mm) wide.
(2) For existing signs, the required wording shall be permitted to
be in plainly legible letters not less than 4 in. (100 mm) high.

Reprinted with permission from NFPA 101®, Life Safety Code®, Copyright© 2006, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not
the complete and official position of the National Fire Protection Association on the reference subject which is represented only by the standard in its entirety.

SURE-LITES®

LIFE SAFETY CODE®: NATIONAL FIRE PROTECTION ASSOC.

way of exit access and that is located or arranged so that it is likely to
be mistaken for an exit shall be identified by a sign that reads as
follows:
NO
EXIT
7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 2 in. (51
mm) high, with a stroke width of 3/8 in. (9.5 mm), and the word EXIT
in letters 1 in. (25 mm) high, with the word EXIT below the word NO,
unless such sign is an approved existing sign.
7.10.8.4 Elevator Signs. Elevators that are a part of a means of egress
(see 7.2.13.1) shall have the following signs with a minimum letter
height of 5/8 in. (16 mm) posted in every elevator lobby:
(1) *Signs that indicate that the elevator can be used for egress,
including any restrictions on use
(2) *Signs that indicate the operational status of elevators
7.10.9 Testing and Maintenance.
7.10.9.1 Inspection. Exit signs shall be visually inspected for operation
of the illumination sources at intervals not to exceed 30 days or shall
be periodically monitored in accordance with 7.9.3.1.3.
7.10.9.2 Testing.
Exit signs connected to or provided with a battery-operated emergency illumination source, where required in 7.10.4, shall be tested
and maintained in accordance with 7.9.3.

FIGURE 7.10.6.2.1 Chevron-Type Indicator.
7.10.6.2.2 The requirements of 7.10.6.2.1 shall not apply to approved
existing signs.
7.10.6.3* Level of Illumination. Externally illuminated signs shall be
illuminated by not less than 5 ft-candles (54 lux) at the illuminated
surface and shall have a contrast ratio of not less than 0.5.

Life Safety Code: National Fire Protection Association

(3) The word EXIT shall be in letters of a width not less than 2 in.
(51 mm), except the letter I, and the minimum spacing
between letters shall be not less than 3/8 in. (9.5 mm).
(4) Sign legend elements larger than the minimum established in
7.10.6.1.1(1) through 7.10.6.1.1(3) shall use letter widths,
strokes, and spacing in proportion to their height.
7.10.6.1.2 The requirements of 7.10.6.1.1 shall not apply to marking
required by 7.10.1.3 and 7.10.1.6.
7.10.6.2* Size and Location of Directional Indicator.
7.10.6.2.1 Directional indicators, unless otherwise provided in
7.10.6.2.2, shall comply with the following:
(1) The directional indicator shall be located outside of the EXIT
legend, not less than 3/8 in. (9.5 mm) from any letter.
(2) The directional indicator shall be of a chevron type, as shown
in Figure 7.10.6.2.1.
(3) The directional indicator shall be identifiable as a directional
indicator at a distance of 40 ft (12m).
(4) A directional indicator larger than the minimum established
for compliance with 7.10.6.2.1(3) shall be proportionately
increased in height, width and stroke.
(5) The directional indicator shall be located at the end of the sign
for the direction indicated.

TECHNICAL INFORMATION >

TECHNICAL INFORMATION -

7.10.7 Internally Illuminated Signs.
7.10.7.1 Listing. Internally illuminated signs shall be listed in accordance with UL 924, Standard for Emergency Lighting and Power
Equipment, unless they meet one of the following criteria:
(1) They are approved existing signs.
(2) They are existing signs having the required wording in legible
letters not less than 4 in. (100mm) high.
(3) They are signs that are in accordance with 7.10.1.3 and
7.10.1.6.
7.10.7.2* Photoluminescent Signs.
The face of a photoluminescent sign shall be continually illuminated
while the building is occupied. The illumination levels on the face of
the photoluminescent sign shall be in accordance with its listing. The
charging illumination shall be a reliable light source as determined
by the authority having jurisdiction. The charging
light source shall be of a type specified in the product markings.
7.10.8 Special Signs.
7.10.8.1 Sign Illumination.
7.10.8.1.1 Where required by other provisions of this Code, special
signs shall be illuminated in accordance with 7.10.5, 7.10.6.3, and
7.10.7.
7.10.8.1.2 Where emergency lighting facilities are required by the
applicable provisions of Chapter 12 through Chapter 42, the required
illumination of special signs shall additionally be provided under
emergency lighting conditions.
7.10.8.2 Characters. Special signs, where required by other provisions
of this Code, shall comply with the visual character requirements of
ICC/ANSI A117.1, American National Standard for Accessible and
Usable Buildings and Facilities.
7.10.8.3* No Exit.
7.10.8.3.1 Any door, passage, or stairway that is neither an exit nor a
Reprinted with permission from NFPA 101®, Life Safety Code®, Copyright© 2006, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not
the complete and official position of the National Fire Protection Association on the reference subject which is represented only by the standard in its entirety.

COOPER LIGHTING

109

INDEX

SURE-LITES®
NUMERICAL INDEX
PRODUCT NO.

PAGE NO.

059012SP
0590A638SP
0590A639SP
12T12DMHWH
12T12DWMHWH
12T12DWXX
12T12MHWH
12T12WMHWH
12T12WXX
12T12XXU
12T37DWMHWH
12T37WMHWH
12T50DMHWH
12T50DWMHWH
12T50MHWH
12T50WMHWH
12T8DWMHWH
12T8DWXX
12T8WMHWH
12T8WXX
12T8XXU
12X12DWMHWH
12X12WMHWH
12X12XXU
12X18DWMHWH
12X18WMHWH
12X25DWMHWH
12X25DWXX
12X25HZB
12X25HZP
12X25WMHWH
12X25WXX
12X25XXU
12X30DWMHWH
12X30WMHWH
12X9WHU
12XW12DWMHWH
12XW12DWXX
12XW12WMHWH
12XW12WXX
12XW9DWMHWH
12XW9DWXX
12XW9WMHWH
12XW9WXX
1BR
1MS
1RTPL
20
29-03
29-08
29-09
29-114
29-12
29-121
29-124
29-125
29-126
29-129
29-13
29-130
29-132
29-134
29-135
29-137
29-139
29-14
29-140

110

COOPER LIGHTING

86
86
86
34
34
33
34
34
33
33
34
34
34
34
34
34
34
33
34
33
33
34
34
33
34
34
34
33
37
37
34
33
33
34
34
33
34
33
34
33
34
33
34
33
86
86
85
103
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105

PRODUCT NO.

29-141
29-142
29-143
29-144
29-146
29-15
29-16
29-17
29-18
29-19
29-24
29-26
29-30
29-36
29-37
29-39
29-40
29-45
29-53
29-54
29-55
29-66
29-75
29-79
29-80
29-84
29-86
29-88
2M
30
3BR
3M
65
6T10DWMHWH
6T10WMHWH
6T12DMHWH
6T12DWMHWH
6T12MHWH
6T12WMHWH
6T12XXU
6T20DWMHWH
6T20WMHWH
6T6DMHWH
6T6DWMHWH
6T6DWXX
6T6MHWH
6T6WMHWH
6T6WXX
6T6XXU
6T8DWMHWH
6T8DWXX
6T8WMHWH
6T8WXX
6T8XXU
6X12DWMHWH
6X12WMHWH
6X12XXU
6X18DWMHWH
6X18WMHWH
6X25DWMHWH
6X25WMHWH
6X25XXU
6X54XXU
6X7DWMHWH
6X7DWXX
6X7MHWH
6X7WMHWH

PAGE NO.

105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
86
103
86
86
103
34
34
34
34
34
34
33
34
34
34
34
33
34
34
33
33
34
33
34
33
33
34
34
33
34
34
34
34
33
33
34
33
34
34

PRODUCT NO.

PAGE NO.

6X7WXX
33
6X7XXU
33
6X8DWMHWH
34
6X8WMHWH
34
6X9DWXX
33
6X9WXX
33
6X9XXU
33
6XW54DWMHWH
34
6XW54DWXX
33
6XW54WMHWH
34
6XW54WXX
33
6XW7DWMHWH
34
6XW7DWXX
33
6XW7WMHWH
34
6XW7WXX
33
6XW9DWMHWH
34
6XW9DWXX
33
6XW9WMHWH
34
6XW9WXX
33
70
103
85
103
90
103
95
103
A
103
AA1
32
AA8
32
AD277CAX
81
AD277CAXBZ
81
AD277CAXW
81
AD2C120CAX
81
AD2C1277CAX
81
AD2CUCAX
81
AEL1BKSD
8
AEL1BZSD
8
AEL1WHSD
8
AP series
64, 65
AP2SQ
63
BZ1
81
C3FT004
101
C3FT006
101
C3FT008
101
C3FT010
101
C3FT012
101
C3FT016
101
C3FT024
101
C3FT033
101
C3FT040
101
C3FT050
101
C7213EEMSL
17
CAN277ELX
81
CAN571
84
CAN578
84
CAR Series
48, 49
CAX Series
42, 43, 44, 45
CAX18PKBK
83
CAX18PKBZ
83
CAX18PKHTBK
84
CAX18PKHTBZ
84
CAX18PKHTWH
84
CAX18PKWH
83
CAX3PP
82
CAX3PPBZ
82
CAX3PPW
82
CAXSBOXBKSP
84
CAXSBOXBZSP
84
CAXSBOXWHSP
84
CC10SD
25

PRODUCT NO.

CC11SD
CC12SD
CC2
CC2347
CC3
CC3NC
CC4
CC4NC
CC5
CC5NC
CC6
CC7
CC7NCSD
CC8
CC9SD
CCX Series
CCX18PKBK
CCX18PKHTBK
CCX18PKHTWH
CCX18PKWH
CCX277
CCXH SERIES
CFR103
CFR116
CFR203
CFR216
CHEL Series
CHEL1BKSD
CHEL1SD
CHEL1WHSD
CHX203
CHX203C
CHX206
CHX206C
CHX209
CHX209C
CHX212
CHX212C
CHX218C
CHX221C
CHX224C
CHX303
CHX303C
CHX303DH
CHX303DHC
CHX306
CHX306C
CHX306DH
CHX306DHC
CHX309
CHX309C
CHX309DH
CHX309DHC
CHX312
CHX312C
CHX312DH
CHX312DHC
CHX318C
CHX318DHC 110
CHX321C
CHX321DHC
CHX324C
CHX324DHC
CHX403
CHX403C
CHX406
CHX406C

PAGE NO.

25
25
21
21
22
22
22
22
22
22
22
23
23
24
25
52, 53, 54
83
84
84
83
81
54
36
36
36
36
9, 88
9
9
9
94
94
94
94
94
94
94
94
94
94
94
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
94
94
94
94

NUMERICAL INDEX
PRODUCT NO.

CHX409
CHX409C
CHX412
CHX412C
CHX418C
CHX421C
CHX424C
CHX503
CHX503C
CHX503DH
CHX503DHC
CHX506
CHX506C
CHX506DH
CHX506DHC
CHX509
CHX509C
CHX509DH
CHX509DHC
CHX512
CHX512C
CHX512DH
CHX512DHC
CHX518C
CHX518DHC
CHX521C
CHX521DHC
CHX524C
CHX524DHC
CHX603
CHX603C
CHX606
CHX606C
CHX609
CHX609C
CHX612
CHX612C
CHX618C
CHX621C
CHX624C
CHX703
CHX703C
CHX706
CHX706C
CHX709
CHX709C
CHX712
CHX712C
CHX718C
CHX721C
CHX724C
CHXH303
CHXH303C
CHXH306
CHXH306C
CHXH309
CHXH309C
CHXH312
CHXH312C
CHXH318C
CHXH321C
CHXH324C
CHXH503
CHXH503C
CHXH506
CHXH506C
CHXH509

PAGE NO.

94
94
94
94
94
94
94
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
94
94
94
94
94
94
94
94
94
94
94
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95

PRODUCT NO.

CHXH509C
CHXH512
CHXH512C
CHXH518C
CHXH521C
CHXH524C
CMFT005
CMFT010
CMFT015
CMFT020
CSK120
CSK277
CU1
CU1347
CU1HD
CU1HD347
CU1NC
CU1R
CU1RB
CU2
CX Series
DR112
DR145
DR166
DR212
DR245
DR266
EAC100012
EAC10003
EAC10006
EAC10009
EAC100112
EAC10013
EAC10016
EAC10019
EAC120012
EAC12003
EAC12006
EAC12009
EAC120112
EAC12013
EAC12016
EAC12019
EAC200012
EAC20003
EAC20006
EAC20009
EAC200112
EAC20013
EAC20016
EAC20019
EAC220012
EAC22003
EAC22006
EAC22009
EAC220112
EAC22013
EAC22016
EAC22019
EAC300018
EAC300021
EAC300024
EAC300118
EAC300121
EAC300124
EAC320018
EAC320021

PAGE NO.

95
95
95
95
95
95
98
98
98
98
85
85
26
26
26
26
26
36
36
27
41
36
36
36
36
36
36
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96

PRODUCT NO.

EAC320024
EAC320118
EAC320121
EAC320124
EAC400012
EAC40003
EAC40006
EAC40009
EAC420012
EAC42003
EAC42006
EAC42009
EAC500012
EAC50003
EAC50006
EAC50009
EAC520012
EAC52003
EAC52006
EAC52009
EAC600018
EAC600021
EAC600024
EAC620018
EAC620021
EAC620024
EEX Series
ELX Series
EMS277
EPX5000B
EPX5000P
ES Series
EUR Series
EUS Series
FBP140X
FBP240C
FBP240D
FBP240H
FBP240HSD
FBP240HU
FBP240M
FBP240U
FBP3500
FBP450LP
FL1
FRK1
G2277CXBLED
G2277CXLED
G2CX
G2CXB
G2CXBLED
G2CXBS
G2CXLED
GC15012
GC15022
GC15032
GC15042
GC15052
GC15072
GC15072CL
GC15082
GC15082CL
GC15122
GC15132
GC15142
GC15172
GC15182

PAGE NO.

96
96
96
96
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
55
38
85
82
82
40
57
56
76, 93
76, 93
76, 93
76, 93
76
76
76, 93
6, 93
76, 93
76
81
86
60
60
60
60
60
60
60
13
13
13
13
13
91
91
91
91
13
13
13
13
13

PRODUCT NO.

GFR2703
GFR2716
H274EM
HR117
HR117C
HR12117
HR12117C
HR12170
HR12170C
HR12210
HR12210C
HR12360
HR12360C
HR180
HR180C
HR87
HR87C
HS1R
HZU125425
HZX21
HZX22
HZX23
IC1
IC10
IC2
IC3
IC4
IC5
IC6
IC7
IC8
IC9
INCX Series
ISC015
ISC022
ISC030
ISC037
ISC048
ISC060
ISC080
ISC100
ISC125
ISC167
L010777
LM1
LPX Series
LPX(H) Series
LTC1
LTC2
MH
ML1
ML2
ML3
ML4NC
ML5NC
MML1
MML2
MR12T12
MR12T12D
MR6T12
MR6T12D
MRT12T12
MRT12T12D
MRT12T12HAZ
MRT12T12W
MRT12T20
MRT12T20D

INDEX

SURE-LITES®

PAGE NO.

36
36
18
29
90
29
90
29
90
29
90
29
90
29
90
29
90
30
69
75
75
75
99
99
99
99
99
99
99
99
99
99
58
100
100
100
100
100
100
100
100
100
100
105
31
50
51
77
78
103
11
11
11
11
11
10
10
35
35
35
35
35
35
37
37
35
35

COOPER LIGHTING

111

INDEX

SURE-LITES®
NUMERICAL INDEX
PRODUCT NO.

PAGE NO.

MRT12T20HAZ
MRT12T20W
MRT12T50
MRT12T50D
MRT12T50W
MRT6T12
MRT6T12D
MRT6T12HAZ
MRT6T12W
MRT6T5
MRT6T5D
MRT6T5HAZ
MRT6T5W
MRT6T9
MRT6T9D
MRT6T9HAZ
MRT6T9W
NCB110
NCB12180
NCB12225
NCB1290
NCB45
NCB9
OF2CX
OF2CXB
OF2CXBS
P4C1
P4C2
P4C22
P4C3
P4C6
P4C7
P4C72
PCL
PHL Series
PK18BK
PK18HTBK
PK18HTWH
PK18WH
PLC277B
PLC277P
PLC2C120
PLC2C1277
PLC2CU
PLX5200GB
PLX5200GBS
PLX5200GP
PLX5200OB
PLX5200OBS
PLX5200OP
PLX5200RB
PLX5200RBS
PLX5200RP
PLX6200GB
PLX6200GBS
PLX6200GP
PLX6200OB
PLX6200OBS
PLX6200OP
PLX6200RB
PLX6200RBS
PLX6200RP
PLX7200GB
PLX7200GBS
PLX7200GP
PLX7200OB
PLX7200OBS

112

COOPER LIGHTING

37
37
35
35
37
35
35
37
37
35
35
37
37
35
35
37
37
67
67
67
67
67
67
60
60
60
15
15
15
15
15
15
15
103
74
83
84
84
83
81
81
81
81
81
60
60
60
60
60
60
60
60
60
61
61
61
61
61
61
61
61
61
61
61
61
61
61

PRODUCT NO.

PLX7200OP
PLX7200RB
PLX7200RBS
PLX7200RP
PLX7202GB
PLX7202GBS
PLX7202GP
PLX7202OB
PLX7202OBS
PLX7202OP
PLX7202RB
PLX7202RBS
PLX7202RP
R2277CXBLED
R2277CXLED
R2CX
R2CXB
R2CXBLED
R2CXBS
R2CXLED
R4C14
R4C145
RBP13
RBP13347
RBP1826
RBP1826347
RBP
RBP9347
RD1
RD3
RD4
RD6
RD7
REM240
RFR130
RFR153
RG1
RG2
RKRC Series
RKRI Series
RLM1
RLM2
RLM3
RLM4
RLM8
RLM9
SLC1
SLC120
SLC120H
SLC1H
SLC2
SLC220
SLC220H
SLC2H
SLX Series
ST1
STL
STL2
TDM
TH
TPK1CP
TPX Series
TRX1 Series
UEL Series
UMB1
UMB14
UMB15

PAGE NO.

61
61
61
61
62
62
62
62
62
62
62
62
62
60
60
60
60
60
60
60
37
37
80
80
80
80
80
80
12
12
12
12
12
80
37
37
16
16
79
79
12
12
12
12
12
12
14
14
14
14
14
14
14
14
59
92
19
20
103
103
86
46, 47
73
66, 87
68
68
68

PRODUCT NO.

UMB16
UMB17
UMB6
UMB7
UMB8
UMB9
UMX Series
UN1OFB
UN1OFBS
UN1OFW
UN1SGB
UN1SGBLED
UN1SGBS
UN1SGW
UN1SGWLED
UN1SRB
UN1SRBLED
UN1SRBS
UN1SRW
UN1SRWLED
UNH1OFB
UNH1OFBDH
UNH1OFBS
UNH1OFBSDH
UNH1OFW
UNH1OFWDH
UNH1SGB
UNH1SGBDH
UNH1SGBLEDL
UNH1SGBS
UNH1SGBSDH
UNH1SGW
UNH1SGWBDHL
UNH1SGWBLED
UNH1SGWDH
UNH1SGWDHL
UNH1SRB
UNH1SRBDH
UNH1SRBLED
UNH1SRBS
UNH1SRBSDH
UNH1SRW
UNH1SRWBDHL
UNH1SRWDH
UNH1SRWDHL
UNH1SRWLED
USF1
UX Series
V
VK1
VRSD
VRSPD
VRX Series
VS1
VS1WP
VS2
VS2WP
WatchGuard EMS SD
WG1
WG10
WG12
WG17
WG19
WG2
WG3
WG4
WG5

PAGE NO.

68
68
68
68
68
68
71
61
61
61
61
61
61
61
61
61
61
61
61
61
61
62
61
62
61
62
61
62
61
61
62
61
62
61
62
62
61
62
61
61
62
61
62
62
62
61
86
70
103
85
86
86
72
83
83
83
83
104
83
83
83
83
83
83
83
83
83

PRODUCT NO.

WG6
WG7
WG8
WG9
WGS11
XR11
XR11347
XR12206
XR12206347
XR12206C
XR12208
XR12208347
XR12208C
XR15
XR16
XR1624C
XR16
XR17
XR20
XR20C
XR21
XR21C
XR3
XR3347
XR5
XR6C
XR7
XR7C
XR9
XR9C
Z-67
Z-7

112

PAGE NO.

83
83
83
83
83
28
28
28
28
89
28
28
89
28
28
89
89
28
28
89
28
89
28
28
28
89
28
89
28
89
105
105

C O O P E R L I G H T I N G B R A N D FA M I LY
MCGRAW-EDISON
Durable, efficient HID fixtures
illuminate a complete range of
outdoor industrial utility and
commercial applications.

AMETRIX
A complete vocabulary of point source
indirect luminaires including ceiling,
suspended, semi-recessed and cove
versions available with compact
fluorescent, tungsten-halogen, and
metal halide light sources.

PORTFOLIO
Developing the visual design concept
with lighting employs an intelligent
ballance of art and science. Portfolio
applies a similar approach to the
design of luminaires with the controlled balance of visual comfort and
efficiency.

HALO
Quality recessed, track and surface
products serve a wide range of
commercial, residential, institutional
and industrial applications.

INVUE
Establishing a new benchmark in
specification grade architectural site
lighting, INVUE Lighting Systems
bring together leading edge form and
unmatched performance.

NEO-RAY
If yours is a never-ending quest to
transform architectural spaces into
dynamic environments, look to Neo-Ray
for lighting products that offer a
distinctive combination of high quality
and aesthetics.

FAIL-SAFE
Security fixtures, control systems and
specialty hardware built to withstand
the rigors of correctional facilities,
clean rooms, public access areas,
hospitals and other high abuse
environments.

METALUX
Single source fluorescent lighting for
commercial, industrial, institutional, retail
and residential markets.

IRIS
Aesthetics and performance combine
for highly flexible architectural,
residential and commercial lighting
designs.

LUMARK
A full-line of quality commercial and
industrial products to satisfy virtually
every indoor or outdoor HID lighting
need.

LUMIERE
Innovative solutions for complex
landscape, area/accent and special
application illumination.

CORELITE
Corelite offers a unique line of affordable
architectural fluorescent luminaires
perfectly suited to the creation of taskfriendly environments.

RSA
RSA is recognized as the leader in the
development of cutting-edge, architectural lighting systems. As innovators in the
design and manufacture of multi-lamp
recessed, track and linear lighting, RSA
products emphasize unique and functional design.

The Power Behind The Brands.

SHAPER
Shaper's standard product line
includes interior ceiling mounted and
pendant luminaires, interior and exterior, wet listed wall mounted fixtures,
a selection of exterior bollard designs
and the “Starter Collection," geared to
budget oriented projects.

Customer First Center
1121 Highway 74 South
Peachtree City, Georgia 30269
770 486 4800
Fax 770 486 4801

Domestic Facilities, USA
Cranbury, New Jersey
Elk Grove Village, Illinois
Irving, Texas
Ontario, California
Peachtree City, Georgia
International Sales, USA
Cooper Lighting
1121 Highway 74 South
Peachtree City, Georgia 30269
770 486 4800
Fax 770 486 4801

The Cooper Lighting Family
Halo
Metalux
Lumark
Sure-Lites
Neo-Ray
Corelite
Portfolio
Iris
Shaper
Lumière
Invue
McGraw-Edison
Streetworks
Fail-Safe
MWS
DLS
RSA
Ametrix

Canada
Cooper Lighting
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
905 507 4000
FAX 905 568 7049
Domestic Facilities, Canada
Calgary, Alberta T2E 7V9
Chomedey, Laval P.Q.

Cooper Lighting, Inc.
All rights reserved
Printed in USA

Dimensions and specifications are subject
to change without notice.

www.cooperlighting.com

ADX070284



Navigation menu