SureLites_wpc:Surelites
2014-06-02
: Pdf 376390-Attachment 376390-Attachment 662400 Batch4 unilog
Open the PDF directly: View PDF .
Page Count: 116
Download | |
Open PDF In Browser | View PDF |
SURE-LITES ® Exit and Emergency Lighting EMERGENCY LIGHTS EXIT SIGNS ALL PRO EMERGENCY INDUSTRIAL & HAZARDOUS RETROFIT ACCESSORIES CHICAGO CODE LIGHTING INVERTERS EXIT SIGNS SURE-LITES ® EMERGENCY LIGHTING EMERGENCY LIGHTS EXIT SIGNS ALL PRO EMERGENCY INDUSTRIAL & HAZARDOUS RETROFIT ACCESSORIES CHICAGO CODE LIGHTING INVERTERS SURE-LITES The TRUSTED name for emergency lighting Offering a COMPREHENSIVE LINE of emergency lights, exit signs, lighting inverters, and retrofit products. A full range of INNOVATIVE SOLUTIONS are available from routine COMMERCIAL to upscale ARCHITECTURAL to hazardous INDUSTRIAL locations. ALL products are UL 924 LISTED and comply with THE LIFE SAFETY CODE (NFPA 101). In addition, a complete line of ENERGY EFFICIENT products are available to significantly reduce energy consumption and exceed conservation standards. Thinking ahead, a DEDICATED engineering group focuses on advanced technology to continue developing more effective ways to provide emergency lighting. ® SURE-LITES - RELIABILITY GUARANTEED. INTRODUCTION ® INTRODUCTION EMERGENCY LIGHTS INTRODUCTION EXIT SIGNS < TABLE OF CONTENTS > EMERGENCY LIGHTS ARCHITECTURAL AEL Series p. 8 CHEL Series p. 9 MML Series p. 10 ML Series p. 11 RD Series p. 12 RLM Series p. 12 GC Series p. 13 SLC Series p. 14 P4C Series p. 15 RG Series p. 16 C7213EEMSL p. 17 H274EM p. 18 StairLite p. 19 StairLite 2 p. 20 CC2 Series p. 21 CC3, 4, 5, 6 Series p. 22 CC7 Series p. 23 CC8 Series p. 24 CC9, 10, 11, 12 Series p. 25 CU1 Series p. 26 CU2 Series p. 27 XR Series p. 28 HR Series p. 29 HS1R Series p .30 LM1 Series p. 31 AA1 Series p. 32 6V, 12V Plastic Weatherproof 6V, 12V Metal Head 6V, 12V Metal Head6V, 12V MR16 Weatherproof p. 35 MR (Metrolite) CFR Series p. 34 p. 35 p. 36 Ultimate Remote Head Series HZB/HZP Series COMMERCIAL REMOTE 6V, 12V Plastic p. 33 p. 33 p. 34 DR Series CU Series GFR Series R4C Series RFR Series p. 36 p. 36 p. 36 p. 37 p. 37 p. 37 p. 37 < TABLE OF CONTENTS > EXIT SIGNS ARCHITECTURAL ELX-AC Series ELX-SP Series ES Series CX Series CAX Series TPX Series CAR Series p. 38 p. 39 p. 40 p. 41 p. 42 p. 46 p. 48 CCX Series p. 52 EEX Series p. 55 EU Series p. 56 INCX Series p. 58 SLX Series p. 59 R/G/OF/PLX Series p. 60 COMMERCIAL LPX Series p. 50 UN/UNH/PLX Series p. 61 ALL PRO APSSQ Series p. 63 AP60/70 Series p. 64 AP70..DH Series p. 65 < TABLE OF CONTENTS > INDUSTRIAL & HAZARDOUS LOCATIONS UEL Series p. 66 NCB Series p. 67 UMB Series p. 68 TRX Series p. 73 PHL Series Photoluminescent p. 74 HZX Series p. 75 HZU1254 Series p. 69 UX Series p. 70 UMX Series p. 71 VRX Series p. 72 RETROFIT FBP LTC LTC2 RKRC, RKRI REM, RBP 277 CONVERSION FTBR CONVERSION p. 76 p. 77 p. 78 p. 79 p. 80 CANOPY p. 81 CANOPY p. 81 EMERGENCY POWER PACK p. 82 CAX EMERGENCY POWER PACK p. 82 Polycarbonate Shield Wire Guards Pendant Kits Canopy Kits p. 83 p. 83, 84 p. 84 p. 83 Cord Sets p. 85 Mounting Brackets, Mounting Shelves Recessing Kits p. 86 p. 86 CAX Series Splice Box Switching Accessories Remote Test Swith & Pilot Light p. 84 p. 85 p. 85 Tamper Proof Screws & Screwdriver Bits p. 86 CHICAGO CODE UEL Series CHEL Series XR Series HR Series GC Series ST1 Series FBP Series p. 87 p. 88 p. 89 p. 90 p. 91 p. 92 p. 93 CHX Series EAC Series p. 94 p. 96 LIGHTING INVERTERS Micro Inverter SeriesLifeway II Single p. 98 Phase IPS Series p. 99 Lifeway II Single Phase C Series p. 100 Lifeway II Three Phase Series p. 101 < TABLE OF CONTENTS > ACCESSORIES Architectural EMERGENCY LIGHTS > SURE-LITES® DESCRIPTION ARCHITECTURAL EMERGENCY LIGHT SERIES DIE CAST ALUMINUM EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz DIMENSIONS > Die cast aluminum housing with powder coat finish > Watchguard EMS Self-Diagnostic System [276.23mm] 3 7/8” [98.43mm] 7” [177.8mm] Self-Diagnostics The self-diagnostic unit will automatically perform the tests required by the NFPA 101 Life Safety Code. The system indicates the status of the unit at all times using an LED indicator that is located near the test switch. Verify proper operation of the transfer circuit and emergency lamps with a convenient laser pointer (sold as an accessory). > Three 6V, 6W High output Xenon lamps > Sealed Nickel Cadmium Battery Maintenance Free, Long Life, Full Recharge time, 24 Hours 10 7/8” The Architectural Emergency Light is designed to provide superior illumination while blending into the surrounding space. The housing is constructed of die cast aluminum with an integral refractive polycarbonate lens. The emergency light’s advanced optical design in conjunction with high output Xenon lamps provide maximum path of egress lighting performance. The Sure-Lites Architectural Emergency Light is listed for temperatures between 20°C and 40°C (-4°F and 104°F) and has silicone gaskets that provide protection from moisture and rain. [Remote unit temperature range: -40°C and 65°C (-40°F and 149°F)] Standard features include Watchguard EMS selfdiagnostic system which meets NFPA 101 testing requirements and a FasTest photocell which enables remote testing of the emergency light. E L E C T R I C A L R AT I N G S Lamp Information Rated Wattage to 87 1/2% of Rated D.C. Voltage Model DC Voltage 1 1/2 Hours Type Wattage Number Spacing1 AEL1SD 6 18 Xenon 6 each 11549423 30.0' > Photocell Test Switch (requires accessory LASER for activation) > Universal Pattern Knockouts on rear of housing for direct mounting to junction box > UV Stable Polycarbonate Lens > Line-Latching, Solid-state Voltage Limited Charger, Low-Voltage Disconnect, Brownout Circuit, Overload/Short Circuit Protection, Test Switch/Power Indicator Light > UL Outdoor Wet/Damp Location Listed > UL 924 Listed SelfDiagnostics, Life Safety NFPA 101, NEC/OSHA, Most State and Local Codes O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: AEL1SD Family AEL1=Architectural Emergency Light COOPER LIGHTING Housing Finishes Blank=Silver BK=Black BZ=Bronze WH=White SD=Self Diagnostics (Standard) Options TDM=Time Delay Monitor Remote=Remote Unit Accessories (order separately) LASER=Key Chain, Red Laser Pointer (activation tested at 15 feet) E N E R G Y D ATA AEL1SD Input Current (Max.) 120V = .10A 277V = .07A 1The 8 SD AEL1 AEL1WHSD AEL1BKSD AEL1BZSD "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 8.5 feet. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance. DESCRIPTION DIMENSIONS 11.5” 4.0” [292mm] [102mm] 6.5” [165mm] CHEL SERIES DIE CAST ALUMINUM Architectural The CHEL Emergency Light provides a distinct solution to any emergency lighting application. Constructed of die cast aluminum, the CHEL presents not only a unique shape and design but also provides dependable strength and durability. The two, fully adjustable, high efficiency 12W, MR16 lamps provide maximum path of egress performance. The standard Watchguard EMS self-diagnostic system meets NFPA 101 testing requirements providing assurance that the unit is working properly at all times. The Sure-Lites FASTEST LASER test feature allows remote, 30 second testing of the emergency light. EMERGENCY LIGHTS > SURE-LITES® EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz > Die cast aluminum housing with powder coat finish Self-Diagnostics The self-diagnostic unit will automatically perform the tests required by the NFPA 101 Life Safety Code. The system indicates the status of the unit at all times using an LED indicator that is located near the test switch. > Two Fully adjustable heads with 6V, 12W MR16 lamps Verify proper operation of the transfer circuit and emergency lamps with a convenient laser pointer (sold as an accessory). > Sealed Lead Calcium Battery Maintenance Free, Long Life, Full Recharge time, 24 Hours E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage > Watchguard EMS SelfDiagnostic System Lamp Information Model DC Voltage 1 1/2 Hours Type Wattage Number Spacing1 CHEL1SD 6 24 MR16 12 29-140 50.0' > Remote Photocell Test Switch (requires accessory LASER for activation) > Universal Pattern Knockouts on rear of housing for direct mounting to junction box O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: CHEL1SD > Snap Fit Design SD CHEL1 > Reversible Mounting Family CHEL1=Architectural Emergency Light Housing Finishes Blank=Silver BK=Black WH=White SD=Self Diagnostics (Standard) Options TDM=Time Delay Monitor Accessories (order separately) LASER=Key Chain, Red Laser Pointer (activation tested at 30 feet) > Line-Latching, Solid-state Voltage Limited Charger, Low-Voltage Disconnect, Brownout Circuit, Overload/Short Circuit Protection, Test Switch/Power Indicator Light > UL Damp Location Listed > UL 924 Listed SelfDiagnostics, Life Safety NFPA 101, NEC/OSHA, Most State and Local Codes E N E R G Y D ATA CHEL1SD Input Current (Max.) 120V = .05A 277V = .02A CHEL1BKSD CHEL1WHSD CHEL1SD (Reverse Mounted) 1The "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.5 feet. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance. COOPER LIGHTING 9 DESCRIPTION The Metrolite MML Series has a sculptured and compact appearance that makes it perfect for quality interior applications. The self-contained, feature rich design packs a powerful punch with its superbright halogen lamp and precision optics. The integral mounting plate makes installation fast and easy. EMERGENCY LIGHTS > Architectural SURE-LITES® DIMENSIONS MML SERIES METROLITE EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz > Injection-Molded, HighImpact, Thermoplastic Housing, Rated UL 94-5VA, Designer-White Textured Finish, Integral Mounting Plate > Glare Free Lens, Fully Adjustable, Halogen Lamps > Sealed Lead Calcium Battery Maintenance Free, Long Life, Full Recharge time, 24 Hours (max.) > Line-Latching, Low-Voltage Disconnect, Test Switch, AC Power Indicator, Brownout Circuit E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2 % of Rated D.C. Voltage Model DC Voltage 1 1/2 Hours Type Wattage Number MML1 MML2 4 4 4.8 9.6 Tungsten Halogen Tungsten Halogen 4.8W 4.8W ea L010777 L010777 O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: MML1 > UL 924, Life Safety NFPA 101, NEC/OSHA, Most State and Local Codes Model Number MML1 MML2 E N E R G Y D ATA Input Current (Max.) MML1 120V = .037A 277V = .019A MML2 120V = .074A 277V = .038A 10 COOPER LIGHTING Lamp Information Accessories (Order separately) VS1 = Polycarbonate Vandal Shield WG8 = Wire Guard MML1 WG9 = Wire Guard MML2 DESCRIPTION The Metrolite ML Series is the right choice for installations where aesthetics are a priority. With its white finish and sculptured compact design the product blends in with the surroundings. Matching remotes are available to insure a consistent appearance. The pleasing look is accompanied by a feature rich design that provides fully adjustable heads with high efficiency halogen lamps making it easy to direct ample light to the required areas. Each unit employs a quick mount universal back with hinged access for hassle free installation. DIMENSIONS Architectural ML SERIES METROLITE EMERGENCY LIGHTS > SURE-LITES® METROLITE EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2 % of Rated D.C. Voltage Model DC Voltage ML1 ML2 ML3 ML4NC ML5NC 6 6 12 6 12 1 1/2 Hours 25 50 50 14 28 Lamp Information Remote Wattage Available 0 26 26 0 0 Type Bi-Pin Halogen Bi-Pin Halogen Bi-Pin Halogen Bi-Pin Halogen Bi-Pin Halogen Wattage 12W ea 12W ea 12W ea 6W ea 12W ea Number 029-66 029-66 029-45 029-12 029-45 > Injection-Molded, HighImpact, Thermoplastic Housing, Rated UL 94-5VA, Designer-White Textured Finish, Integral Mounting Plate > Glare Free Lens, Fully Adjustable, Halogen Lamps > Sealed Lead Calcium or Nickel Cadmium Battery Maintenance Free, Long Life, Full Recharge time, 24 Hours (max.) O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: Model Number ML1 ML2 ML3 ML4NC1 ML5NC1 ML1 Options (add as suffix) V = Voltmeter TDM= Time Delay Monitor Alternate Lamps2 Accessories (Order separately) VS1 = Polycarbonate Vandal Shield WG12 = Wire Guard > Line-Latching, Low-Voltage Disconnect, Test Switch, AC Power Indicator, Brownout Circuit > Red LED High Charge Indicator, Amber LED AC Power Indicator > UL 924, Life Safety NFPA 101, NEC/OSHA, Most State and Local Codes E N E R G Y D ATA Input Current (Max.) ML1, ML2, ML3 120V = .3A 277V = .1A ML4NC, ML5NC 120V = .085A 277V = .035A 1NC = Nickel Cadmium Battery. 2Consult your Cooper Lighting Representative. COOPER LIGHTING 11 Architectural EMERGENCY LIGHTS > SURE-LITES® DIMENSIONS DESCRIPTION RD SERIES Tw o I n j e c t i o n M o l d e d T h e rm o p l a s t i c H e a d s The RD Series is a recessed emergency lighting system designed for locations where aesthetics are of utmost importance. The housing is fully recessed in dry wall or grid ceiling installations. Designer pinchback heads rotate 358° and swivel 90° to 0°. Ideal for commercial and institutional environments where easy recessed installation and minimal maintenance are desired. The RLM Series is a recessed system packaged in an attractive flame-resistant metal housing. It is the unit of choice for installations where a recessed product is desired and the size and cost of emergency lighting must be kept to a minimum without sacrificing dependability or light output. RLM SERIES E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of rated D.C. Voltage Tw o H i g h - I m p a c t T h e rm o p l a s t i c H e a d s EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz > 20 gauge die-formed steel housing with white powder coat finish > Heads match housing finish Model Battery DC Voltage 1 1/2 hours 2 hours 3 hours RD1 RD3 RD4 RD6 RD7 RLM1 RLM2 RLM3 RLM4 RLM8 RLM9 SLC SLC SLC SNC SNC SLC SLC SLC SLC SNC SNC 6 6 12 6 6 6 6 6 12 6 6 18 27 54 15 24 10.8 18 27 54 15 24 15 24 12 18 7.2 15 24 12 18 10 18 8 12 10 18 8 12 Lamp Information 4 hours Type 8 14 6 10 8 14 10 SLC=Sealed Lead Calcium Battery SNC=Sealed Nickel Cadmium Battery O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: RD1V > Ceiling or wall mounting > Supplied with hanger bars, T-Bar clips > Single modular electrical connector > Remote capability > Line-latching, Solid-State voltage limited charger, Solid-State switching, low- voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes 12 COOPER LIGHTING Model Number RD1 RD3 RD4 RD6 RD7 RLM1 RLM2 RLM3 RLM4 RLM8 RLM9 Options (Add as suffix) A=Ammeter 1 SD=Self-Diagnostics TDM=Time Delay Monitor V=Voltmeter 1 Alternate Lamps2 Other Options 2 Accessories (Order separately) WG2 =Wire Guard WG7 =Wire Guard VS=Choose polycarbonate vandal shield desired from accessories sheet Energy Data Model No. RD1, RD3 RD4, RLM4 RD6 RD7 RLM1, RLM2, RLM3 RLM8 RLM9 1Provision Input Current (Max.): 120V 277V .12A .05A .30A .13A .06A .03A .07A .04A .12A .05A .06A .03A .07A .04A for one meter only. 2Consult your Cooper Lighting Representative. Tungsten Halogen Tungsten Halogen Incandescent Tungsten Halogen Tungsten Halogen Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Wattage 6 12 9 6 12 5.4 9 9 9 7.2 7.2 Number 29-12 29-66 029-86 29-12 29-66 29-121 29-84 29-84 029-86 29-88 29-88 DESCRIPTION DIMENSIONS GC SERIES Recessed Housing Suspended Ceiling Architectural The GC Series combines a clean, sleek, contemporary appearance with state-of-the-art electronics. Specifically designed for initial and retrofit installations where a recessed unit is desired to maximize aesthetics. The unit is ideal for locations with limited wall space and where panoramic positioning is necessary for the ceiling mounted lampholders to provide proper light distribution. Ideal for stores, offices, hospitals and school corridors. EMERGENCY LIGHTS > SURE-LITES® EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of rated D.C. Voltage Model GC15012 GC15022 GC15032 GC15042 GC15052 GC15122 GC15132 GC15142 GC15172 GC15182 Battery SLC SLC SLC SLC SLC SNC SNC SNC SNC SNC DC Voltage 6 6 6 12 12 6 6 6 12 12 1 1/2 hours 2 hours 3 hours 27 54 85 36 54 15 24 48 30 48 24 48 66 30 48 12 18 36 24 36 18 36 50 20 36 8 12 24 16 24 Lamp Information 4 hours Type 14 28 40 16 28 6 10 20 12 20 Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent SLC=Sealed Lead Calcium Battery SNC=Sealed Nickel Cadmium Battery S A M P L E N U M B E R : G C 1 5 01 2 C L Options (Add as suffix) A=Ammeter CL=Cylinder Heads DR=Halogen Pinchback Designer Heads SD=Self-Diagnostics (GC15012, GC15042, GC15052, GC15122, GC15132, GC15172, GC15182, Only) TDM=Time Delay Monitor V=Voltmeter Alternate Lamps 1 Other Options 1 Number 9 9 9 9 9 7.2 7.2 7.2 9 9 29-84 29-84 29-84 29-86 29-86 29-88 29-88 29-88 29-86 29-86 > 20 gauge die-formed steel housing with white powder coat finish > Two high-impact, fully adjustable thermoplastic heads > Flanged for mounting in grid-type suspended ceilings > Above ceiling access required for maintenance O R D E R I N G I N F O R M AT I O N Model Number GC15012 GC15022 GC15032 GC15042 GC15052 GC15122 GC15132 GC15142 GC15172 GC15182 Wattage > Single modular electrical connector Accessories (Order separately) VK1 =Voltmeter WG12 =Wire Guard WG17 =Wire Guard for use with CL heads > Remote Capability > Line-latching, Solid-State voltage limited charger, Solid-State switching, low- voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes Energy Data Model No. GC15012, GC15022, GC15032 GC15042, GC15052 GC15122 GC15132 GC15142 GC15172 GC15182 1Consult Input Current (Max.): 120V 277V .12A .05A .30A .13A .06A .03A .07A .04A .08A .05A .13A .06A .15A .07A your Cooper Lighting Representative. COOPER LIGHTING 13 DIMENSIONS DESCRIPTION The SLC Series is a solid-state, self-contained emergency lighting system. The architecturally designed heads blend perfectly with the most sophisticated decor. EMERGENCY LIGHTS > Architectural SURE-LITES® SLC SERIES Large Cylinder Head(s) EMERGENCY LIGHT E L E C T R I C A L R AT I N G S - S E A L E D L E A D C A L C I U M B AT T E R Y Rated Wattage to 87 1/2% of rated D.C. Voltage Model > Dual-voltage input 120/277VAC, 60Hz > 18 gauge die formed steel housing with white powder coat finish > Single or double front mounted white thermoplastic fully adjustable heads with glare free lens SLC1 SLC1H SLC2 SLC2H SLC120 SLC120H SLC220 SLC220H Battery No. of Heads DC Voltage 1 1/2 hours SLC SLC SLC SLC SNC SNC SNC SNC 1 1 2 2 1 1 2 2 6 6 6 6 6 6 6 6 10.8 27 18 54 8 24 15 48 2 hours Lamp Information 3 hours 4 hours 7.2 24 15 48 18 12 36 SLC=Sealed Lead Calcium Battery SNC=Sealed Nickel Cadmium Battery O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: SLC1V > Remote capability > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light Model Number SLC1 SLC1H SLC2 SLC2H SLC120 SLC120H SLC220 SLC220H Options (Add as suffix) A=Ammeter 2 TDM=Time Delay Monitor V=Voltmeter2 Alternate Lamps1 Other Options1 Accessories (Order separately) WG5=Wire Guard (1 Head) WG6=Wire Guard (2 Heads) > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes Energy Data Model No. SLC1 SLC1H, SLC2, SLC2H SLC120 SLC120H SLC220 SLC220H 1Consult 14 COOPER LIGHTING Input Current (Max.): 120V 277V .08A .04A .12A .05A .05A .03A .07A .04A .06A .03A .08A .05A your Cooper Lighting Representative. 2Provision for one meter only. 18 10 36 14 8 28 14 8 28 10 6 20 Type Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Wattage Number 9 9 9 9 7.2 7.2 7.2 7.2 29-84 29-84 29-84 29-84 29-88 29-88 29-88 29-88 DIMENSIONS DESCRIPTION P4C SERIES Decorative Square Architectural The P4C Series is a decorative, mini-system that features solid-state electronics and a long-life maintenance free battery. It is designed for surface mounting but may be semi-recessed or fully recessed by using a field-installed recessed kit. The diffused tungsten halogen light source and reliable electronics make the P4C Series ideal for illuminating corridors, stairways, doorways, and offices. EMERGENCY LIGHTS > SURE-LITES® EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz > Black thermoplastic body with white plastic collar and reflector E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of rated D.C. Voltage Model Battery DC Voltage 1 1/2 hours P4C1 P4C2 P4C223 P4C3 P4C6 P4C7 P4C723 SLC SLC SLC SLC SNC SNC SNC 6 6 6 6 6 6 6 10.8 27 27 54 15 24 24 2 hours 7.2 24 24 48 12 18 18 3 hours 18 18 36 8 12 12 Lamp Information 4 hours Type 14 14 28 6 10 10 Bi-Pin Halogen Bi-Pin Halogen Bi-Pin Halogen Bi-Pin Halogen Bi-Pin Halogen Bi-Pin Halogen Bi-Pin Halogen SLC=Sealed Lead Calcium Battery SNC=Sealed Nickel Cadmium Battery Wattage Number 10 10 10 10 10 10 10 29-40 29-40 29-40 29-40 29-40 29-40 29-40 > High-impact acrylic lens with test switch behind flexible lens > Universal J-Box mounting pattern with 1/2” conduit knockouts > Surface mounting, recessed or semi-recessed O R D E R I N G I N F O R M AT I O N > Wall or Ceiling mounting SAMPLE NUMBER: P4C1PCL > Remote capability Model Number P4C1 P4C2 P4C22 P4C3 P4C6 P4C7 P4C72 Options (Add as suffix) PCL=Polycarbonate Lens TDM=Time Delay Monitor V=Voltmeter 2 A=Ammeter2 Other Options 1 Accessories (Order separately) WG7 =Wire Guard USF1=Rough-in Kit for semi-recessed installation 8 1/4"L x 8 1/4"W x 2 7/8"D (210mm x 210mm x 73mm) FRK1=Rough-in Kit for fully recessed installation 9 1/8"L x 9 1/8"W x 5 1/8"D (232mm x 232mm x 130mm) VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weatherproof > Line-latching, Solid-State voltage limited charger, Solid-State switching, lowvoltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes Energy Data Input Current (Max.): Model No. 120V 277V P4C1, P4C2, P4C22, P4C3 .12A .05A P4C6 .06A .03A P4C7, P4C72 .07A .04A 1Consult your Cooper Lighting Representative. 2Only one meter - not compatible with FRK-1. 3 Twin Lamps. COOPER LIGHTING 15 Architectural EMERGENCY LIGHTS > SURE-LITES® DIMENSIONS DESCRIPTION RG SERIES Recessed Gimbal Perfect for commercial or architectural applications where the aesthetics of a fully recessed unit are essential. The slim profile of the RG Series is ideal for low ceilings and blends inconspicuously with existing recessed installations. The gimbal mounted lamp provides directional aiming (optional white gimbal ring offers the perfect blend for suspended ceilings). The RG Series combines a high output sealed beam type lamp, sealed lead calcium battery and full feature Sure-Lites electronics. EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz > Fixture illuminates upon loss of AC power (normally off) > 20 gauge die-stamped steel housing > Polycarbonate lens included > Adjustable aiming angle 30° > Hanger bars accommodate 24" spans and can be rotated 90° on plaster frame E L E C T R I C A L R AT I N G S - S E A L E D L E A D C A L C I U M B AT T E R Y Rated Wattage to 87 1/2% of rated D.C. Voltage DC Voltage 1 1/2 hours 2 hours 3 hours 4 hours Type Wattage Number RG1 6 10.8 7.2 - - Incandescent 9 29-84 RG2 6 27 24 - - Incandescent 25 29-09 O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: RG1WH > Conduit knockouts, four 1/2" and two 3/4" > Trim ring, with integral test switch, held in place with torsion springs Model Number RG1 RG2 > Standard white trim ring/ black gimbal ring > Line-latching, Solid-State voltage limited charger, Solid-State switching, low- voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, CSA Certified, most state and local codes Options (Add as suffix) BK=Black Trim Ring/Black Gimbal Ring WH=White Trim Ring/White Gimbal Ring Alternate Lamps 1 Other Options 1 Energy Data Model No. RG1 Input Current (Max.): 120V 277V .12A .05A RG2 .12A .05A > IC Rated 16 COOPER LIGHTING Lamp Information Model 1Consult your Cooper Lighting Representative. Accessories (Order separately) WG1=Wire Guard DESCRIPTION The C7213EEMSL wide beam downlight features a completely self-contained battery-operated emergency lighting system utilizing energy saving compact fluorescent lamps. This unit provides inconspicuous emergency lighting by blending with Portfolio downlights. It’s designed to provide normal illumination with AC power and 90 minutes of emergency lighting. The fixture may be installed in switched circuits. The battery charge indicator light and test switch are prewired to a quick connect modular plug which also makes the final battery connection for energizing the circuit. DIMENSIONS DESCRIPTION Lamp: 7 3/8 C7213EEMSL 13W 4 Pin Quad Lamp and Lamp Image Cutoff: 55° Architectural Aperture Size: EMERGENCY LIGHTS > SURE-LITES® Recessed/Fluorescent Aperture: 7 3/8" (187mm) Cutout: 8 1/8" (206mm) OD: 8 3/4" (222mm) EMERGENCY LIGHT > Dual voltage input 120V through 277VAC, 50/60 Hz > Die cast aluminum 1 1/2" deep collar O R D E R H O U S I N G , T R I M A N D A C C E S S O R I E S S E PA R AT E LY, L A M P S U P P L I E D B Y O T H E R S > One piece Alzak reflector with spun parabolic contour provides 55° cutoff to lamp and lamp image C7213EEMSL > All finishes are low iridescent to eliminate rainbowing Housing C7213EEMSL=7 3/8" 13W (2) Lamp 120V through 277V Trims 7250=Reflector with Polymer Trim 7251=Self Flanged Reflector Finish1 LI=Low Iridescent H=Haze S=Straw WH=Wheat BB=Black Baffle (on 7250 only) WB=White Baffle (on 7250 only) Accessories2 (Order separately) Trim Rings TRM7P=White Metal TRM7MB=Black Metal TRR7=Rimless Slope Ceiling Adapter HSA7XX=Specify Slope 1 1/2" C-Channel Bar Hangers HB26=26" Long HB50=50" Long > Sealed nickel cadmium battery > Exclusive universal mounting bracket adjusts 5" vertically > Junction box with 1/2" and 3/4" pryouts, listed for eight #12g 90°C conductors > Electronic ballasts have integral fuse, >99% power factor and <10%THD. Electronic ballasts have current controlled preheat starting and End of Life protection standard. > Solid state voltage limited charger, overload short circuit protection, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes 1For White Painted Flange (on self flanged reflectors) add WF to Reflector Finish. 2Accessories should be ordered separately. For additional options please consult your Cooper Lighting Representative. COOPER LIGHTING 17 Architectural EMERGENCY LIGHTS > SURE-LITES® DIMENSIONS DESCRIPTION H274EM Recessed/Fluorescent EMERGENCY LIGHT The H274EM uses one 13W compact fluorescent lamp (DTT, 2-Pin) in a H274 fixture. It matches the Halo H274 downlight in appearance and will automatically provide 120 minutes of emergency power. Typically, the H274EM would be installed on a 24 hour circuit but can also be installed on switched circuits (277V unswitched circuits require the EMS277 accessory). The battery charge indicator light and test switch are prewired to a quick connect modular plug which also makes the final battery connection for energizing the circuit. > Dual-voltage input 120/277VAC, 60Hz > 20 gauge die-stamped steel housing with white baked enamel finish > Accommodates all recommended trims > Adjustable socket plate > Initial 900 lumens in emergency mode O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : H 2 74 E M H274EM Model Number H274EM > Hanger bars span 24" and can be rotated 90° on plaster frame > Junction Box has five 1/2" trade size knockouts with true pry-out slots > Line-latching, Solid-State voltage limited charger, Solid-State switching, low- voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light Trims (Order separately) 400RG=Residential Gold Satin Reflector 400SC=Specular Clear Finish Reflector 405CG=Champagne Gold Specular Reflector 405RG=Residential Gold Specular Reflector 405SC=Clear Specular Reflector 409P=Reflector with Black Coilex Baffle Energy Data Model No. H274EM (Starting) H274EM (Operating) Input Power 120V 277V 30W 34W 19W 21W > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes 18 COOPER LIGHTING Accessories (Order separately) EMS277=Accessory for 277V Switching Applications TRM7P=White Metal Trim Ring TRM7MB=Black Metal Trim Ring TRR7=Rimless Trim Ring HB24=24" Bar Hangers Note: Lamp not included. Input Current (Max.) 120V 277V .41A .19A .32A .15A Power Factor 120V 277V >.62 >.66 >.49 >.50 120V <11% <12% T.H.D.: 277V <11% <12% DIMENSIONS DESCRIPTION Dimension “A” FO17T8 27" (686mm) FO25T8 39" (991mm) FO32T8 51" (1295mm) STL STAIRLITE Stairwell Lighting System Architectural Lamp The StairLite System is designed to satisfy all stairwell lighting requirements in one easy to install package. StairLite consists of a surface mounted, two lamp fluorescent lighting fixture that incorporates an integrally mounted ultrasonic motion detector, a system display panel, and an optional full battery backup. The StairLite System will deliver vastly reduced operating and maintenance costs due to virtually no power consumption. It will enhance the usefulness, safety, and reliability of any emergency lighting system. The StairLite System is designed for use in stairwells or any other area of a building where the occupancy level or usage factor would be considered minimal. EMERGENCY LIGHTS > SURE-LITES® EMERGENCY LIGHT > Choice of Input Voltage, 120 or 277 VAC, 60Hz > Formed 20 gauge steel housing and cover plate construction > Durable white powder coat finish > T8 Fluorescent lamps in 17, 25 and 32 watts (Lamps not included) > Single-lamp electronic ballast that is “0” Degree rated O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: STL42F17 STL Family STL=StairLite Operation 4=AC Only 54=Emergency 450 Lumens 57=Emergency 700 Lumens 59=Emergency 950 Lumens Lamp 2F17=(2) FO17T8 (2' lamps) 2F25=(2) FO25T8 (3' lamps) 2F32=(2) FO32T8 (4' lamps) Voltage Blank=120 VAC 7=277 VAC Accessories (Order Separately) VRSPD=#6 Spanner Screw Driver > Sealed, maintenance-free nickel cadmium battery > Fully automatic, self-test ultrasonic motion detector > Solid-state Status Indicator Display System with an AC power indicator > Fully automatic emergency charger is solid-state–no mechanical relay > Variety of electrical and mounting knockouts for a easy installation > UL 924, Life Safety NFPA 101, NEC/OSHA, most state and local codes Energy Data (2) 17W T8 (2) 25W T8 (2) 32W T8 Lamps Off Input Power; 120V 277V 31W 31W 42W 42W 52W 52W 4.3W 4.3W Input Current (Max.): Power Factor: 120V 277V 120V 277V .29A .13A .8 .8 .36A .16A .8 .8 .44A .19A .9 .9 .04A .02A .7 .7 COOPER LIGHTING 19 Architectural EMERGENCY LIGHTS > SURE-LITES® DIMENSIONS DESCRIPTION The StairLite System is designed to satisfy all stairwell lighting requirements in one easy to install package. The StairLite 2 is a surface mounted, two lamp fluorescent lighting fixture that incorporates an integrally mounted ultrasonic motion detector, a system display panel, and an optional full battery backup. STAIRLITE 2 Stairwell Lighting System EMERGENCY LIGHT > Choice of Input Voltage, 120 or 277 VAC, 60Hz > Formed 20 gauge steel housing and cover plate construction The StairLite 2 includes bi-level lamp operation so that one lamp remains on constantly while the motion detector activates the second lamp when needed to significantly reduce the operate costs. The StairLite System is designed for use in stairwells or any other area of a building where the occupancy level or usage factor would be considered minimal. > Durable white powder coat finish > T8 32W Fluorescent lamps (Lamps not included) > Single-lamp electronic ballast that is “0” Degree rated > Sealed, maintenance-free nickel cadmium battery > Fully automatic, self-test ultrasonic motion detector > Solid-state Status Indicator Display System with an AC power indicator > Fully automatic emergency charger is solid-state–no mechanical relay > Variety of electrical and mounting knockouts for a easy installation > UL 924, Life Safety NFPA 101, NEC/OSHA, most state and local codes 20 COOPER LIGHTING O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: STL24F032T87 STL2 Family STL2=StairLite 2 Operation 4=AC Only 5=Self Powered Lamp Type & Size Blank=(2) 4’ Lamps F032T8 Voltage Blank=120 VAC 7=277 VAC DESCRIPTION DIMENSIONS CC2 Commercial The CC2 Contractor’s Choice Emergency Lighting Unit is an economic, yet attractive, alternative to standard two headed emergency lighting units. All components snap together to facilitate installation in 2 minutes or less. Field adjustability is not sacrificed for price, both lighting heads have full horizontal and vertical adjustability. The Model CC2 Contractor’s Choice is ideal for applications which demand the minimum product cost without sacrificing adjustability, dependability, or aesthetics. EMERGENCY LIGHTS > SURE-LITES® C o n t r a c t o r ’s C h o i c e EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz, isolation transformer > Injection-molded, color- stable, high-impact UL-94-5V rated polycarbonate housing and mounting plate (Housing is tethered to mounting plate) E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of rated D.C. Voltage Lamp Information Model DC Voltage 1 1/2 hours Type Wattage Number CC2 CC22146 CC2MRT CC2SQ 6 6 6 6 Incandescent Krypton MR16 Incandescent 5.4 5.4 5.0 5.4 029121 029146 029139 029121 12 12 12 12 > Designer-white textured finish > Two PAR36 type lamps in fully adjustable highimpact polycarbonate lampholders O R D E R I N G I N F O R M AT I O N > Maintenance Free Sealed Lead Calcium Battery SAMPLE NUMBER: CC2 Model Number CC2 CC2347 (120/347VAC) Options (Add as suffix) MRT=MR16 Head (5W Standard) SQ=Square Head (5.4W Standard) V=Voltmeter CSK120=Cord Set (120VAC) BK=Black Alternate Lamps 1 Other Options 1 Energy Data Model No. CC2 CC2347 1Consult Accessories (Order separately) 1BRWH=Mounting Brackets (2) White WG1=Wire Guard VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weather Resistant > Cutouts provided for surface conduit on top > Universal J-box mounting pattern, keyhole slots > Line-Latching, Solid-State Voltage Limited Charger, Solid-State Switching, Low- Voltage Disconnect, Brownout Circuit, Overload/Short Circuit Protection, Test switch/power Indicator light > UL Damp Location Listed Input Current (Max.): 120V 277V 347V .12A .05A .12A — .01A your Cooper Lighting Representative. > UL 924 Listed, NOM Certified, Life Safety NFPA 101, CSA Certified, NEC/OSHA, most state and local codes COOPER LIGHTING 21 Commercial EMERGENCY LIGHTS > SURE-LITES® DIMENSIONS DESCRIPTION CC3 CC4 CC5 CC6 The CC Series Contractor’s Choice Emergency Lighting Unit is the ideal choice when a simple installation and a reasonable cost are required. Its contemporary round corner styling, designer white finish, and consistent family appearance enables it to blend with any decor. The components are injection molded from tough polycarbonate materials which resist discoloration due to age and ultraviolet radiation. C o n t r a c t o r ’s C h o i c e EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz, isolation transformer E L E C T R I C A L R AT I N G S > Injection-molded, color-stable, high-impact UL-94-5V rated polycarbonate housing and mounting plate (Housing is tethered to mounting plate) Model CC3 CC3 NC CC4 CC4 NC CC5 CC5 NC CC6 Rated Wattage to 87 1/2% of rated D.C. Voltage DC Voltage 1 1/2 hours 6 10.8 6 16 6 18 6 18 6 27 6 24 6 32 2 hours 7.2 15 3 hours 10 4 hours 8 24 18 14 - - - Lamp Information Type Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Wattage 5.4 5.4 9 9 9 9 9 Number 29-121 29-121 29-84 29-84 29-84 29-84 29-84 > Designer-white textured finish > Two PAR36 type lamps in fully adjustable high-impact polycarbonate lampholders > Sealed lead calcium maintenance free battery > Cutouts provided for surface conduit on top > Universal J-box mounting pattern, keyhole slots > Remote Capability CC5, CC6 O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: Model Number CC3 CC3NC(4) CC4 CC4NC4, 6 CC5 CC5NC4, 6 CC6 CC5WHSD Housing Finish (Must be specified) WH=White BK=Black Voltage Blank=120/277 347=120/347 VAC > Line-Latching, Solid-State Voltage Limited Charger, Solid-State Switching, Low- Voltage Disconnect, Brownout Circuit, Overload/Short Circuit Protection, Test switch/power Indicator light > UL Damp Location Listed (CC5SD Only) > UL 924 Listed, Life Safety NFPA 101, CSA Certified, NEC/OSHA, most state and local codes COOPER LIGHTING Accessories (Order separately) WG1 =Wire Guard WG2 =Wire Guard (use for heads adjusted at 45° or greater) VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weather Resistant CSK120=Cord Set 120V Energy Data Model No. CC3 CC4 CC5 CC6 1Provision 22 Options (add as suffix) MRT=MR16 Heads (5W Standard CC3, CC3NC; 9W Standard CC4, CC5, and CC6) SQ=Square Head (5.4W Standard) A =Ammeter 1 SD=Self-Diagnostics3, 5, 6 V=Voltmeter1 TDM=Time Delay Monitor Alternate Lamps2 Other Options 2 5CC5SD Input Current (Max.): 120V 277V 347V .12A .05A .01A .12A .05A .01A .13A .06A .06A .13A .06A .06A for one meter only. 2Consult your Cooper Lighting Representative. 3Not available w/CC6. 4NC=Nickel Cadmium Battery. is damp location standard. 6CC4NC, CC5NC not available in SD. DIMENSIONS DESCRIPTION 13” [330mm] 4 7/8” [124mm] 7 15/16” MAX [202mm] CC7 5 3/4” [146mm] Commercial The CC7 Contractor’s Choice FasTest™ High Capacity Emergency Lighting Units are an affordable, yet attractive, alternative to standard white twoheaded emergency lighting units. All components snap together to facilitate installation in 5 minutes or less. Field versatility is not sacrificed for cost, both lighting heads offer full horizontal and vertical adjustability. Moreover, proper operation of the transfer circuit and emergency lamps can be quickly and safely verified by using a convenient laser pointer (sold as an accessory). In addition, Watchguard EMS self diagnostic system is standard (CC7NCSD only). EMERGENCY LIGHTS > SURE-LITES® C o n t r a c t o r ’s C h o i c e EMERGENCY LIGHT 19 1/4” MAX [489mm] The CC7 FasTest™ is ideal for applications that demand the minimum cost but also require maximum flexibility, reliability and convenience in an attractive unit. > Dual-Voltage Input 120/277 VAC, 60 Hz > Injection-Molded, ColorStable, High-Impact UL 94-5V Rated Polycarbonate Housing and Mounting Plate Verify proper operation of the transfer circuit and emergency lamps with a convenient laser pointer (sold as an accessory). > Designer white textured finish > Maintenance Free Sealed Lead Calcium Battery or Premium Nickel Cadmium battery (CC7NCSD version only) E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Model DC Voltage 1 1/2 Hours Remote Wattage* CC7 12 60 36 CC7NCSD 12 50 26 Lamp Information Type Wattage Number Incandescent Incandescent 12W ea. 12W ea. 029-132 029-132 > Housing Has (8) Locations for Mounting of Heads; Consult Factory (3 optional bottom-mount and 3 optional top- mount locations) > Knockouts/Cutouts Provided in Housing for Surface Conduit Attachment O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: CC7208BMTDM > Watchguard EMS self diagnostic system (CC7NCSD only) Model Number CC7 CC7NCSD Options (Add as suffix) SQ=Square Head (12W Standard) MRT=MR16 Heads (12W Standard) A=Ammeter V=Voltmeter SD=Self-Diagnostics (CC7NC Only) TDM=Time Delay Monitor Cord Set=CSK-120, CSK-277 SM=Side Mount Heads TM=Top Mount Heads BM=Bottom Mount Heads Alternate Lamps, Head Types, No Head, Multiple Heads1 Other Options1 Accessories (Order separately) LASER=Key Chain, Red Laser Pointer (activation tested at 50 feet) VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weather Resistant WG3=Wire Guard 2MS=Mounting Shelf (Specify Color) Energy Data Model No. CC7 CC7 CC7NCSD 1Consult Input Power Input Current (Max.) Power Factor 120V 277V 120V 277V 120V 277V Charge Mode (Fully Discharged Battery) Sealed Lead Calcium Battery 28W 28W .26A .11A >.91 >.91 Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery 3.8W 3.7W .07A .03A >.50 >.50 Standby Mode 7.8W 7.1W .08A .04A >.77 >.77 your Cooper Lighting Representative. T.H.D. 120V 277V <35% <39% <94% <99% <53% <58% > Remote Photocell Test Switch with Automatic 30-Sec. Test Upon Switch Activation > Line-Latching, Solid-State Voltage Limited Charger, Solid-State Switching, Low-Voltage Disconnect, Brownout Circuit, Overload/Short Circuit Protection, Push-Button Test Switch/Power Indicator Light > UL 924, Life Safety NFPA 101, NEC/OSHA, Most State and Local Codes COOPER LIGHTING 23 Commercial EMERGENCY LIGHTS > SURE-LITES® DESCRIPTION CC8 C o n t r a c t o r ’s C h o i c e High Capacity EMERGENCY LIGHT DIMENSIONS The CC8 Contractor’s Choice FasTest™ High Capacity Emergency Lighting Units are an affordable, yet attractive, alternative to standard white two-headed emergency lighting units. All components snap together to facilitate installation in 5 minutes or less. Field versatility is not sacrificed for cost, both lighting heads offer horizontal and vertical adjustability. Moreover, proper operation of the transfer circuit and emergency lamps can be quickly and safely verified by using a convenient laser pointer (sold as an accessory). 15” [381mm] 3 15/16” [100mm] 7 3/8” MAX [187mm] 7 3/4” [197mm] The CC8 FasTest™ is ideal for applications that demand the minimum cost but also require maximum flexibility, reliability and convenience in an attractive unit. 22” MAX [559mm] > Dual-Voltage Input 120/277 VAC, 60 Hz > Injection-Molded, Color-Stable, High-Impact UL 94-5V Rated Polycarbonate Housing and Mounting Plate Verify proper operation of the transfer circuit and emergency lamps with a convenient laser pointer (sold as an accessory). > Designer white textured finish > Maintenance Free Sealed Lead Calcium Battery E L E C T R I C A L R AT I N G S > Housing Has (8) Locations for Mounting of Heads; Consult Factory (3 optional bottommount and 3 optional top- mount locations) > Knockouts/Cutouts Provided in Housing for Surface Conduit Attachment > Remote Photocell Test Switch with Automatic 30-Sec. Test Upon Switch Activation > Line-Latching, Solid-State Voltage Limited Charger, Solid-State Switching, Low-Voltage Disconnect, Brownout Circuit, Overload/Short Circuit Protection, Push-Button Test Switch/Power Indicator Light Rated Wattage to 87 1/2% of Rated D.C. Voltage Model CC8 DC Voltage 1 1/2 Hours 12 100 Remote Wattage* 76 Lamp Information Type Wattage Number Incandescent 12W ea. 029-132 O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: CC8 CC8 Model Number CC8 > UL 924, Life Safety NFPA 101, CSA Certified, NEC/OSHA, Most State and Local Codes Options (Add as suffix) SQ=Square Head (12W Standard) MRT=MR16 Heads (12W Standard) A=Ammeter V=Voltmeter TDM=Time Delay Monitor Cord Set=CSK-120, CSK-277 SM=Side Mount Heads TM=Top Mount Heads BM=Bottom Mount Heads Alternate Lamps, Head Types, No Head, Multiple Heads1 Other Options1 Accessories (Order separately) LASER=Key Chain, Red Laser Pointer (activation tested at 50 feet) VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weather Resistant WG3=Wire Guard 2MS=Mounting Shelf (Specify Color) Energy Data Model No. CC8 CC8 24 COOPER LIGHTING 1Consult Input Power Input Current (Max.) Power Factor 120V 277V 120V 277V 120V 277V Charge Mode (Fully Discharged Battery) Sealed Lead Calcium Battery 28W 28W .26A .11A >.91 >.91 Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery 4.1W 4.0W .07A .03A >.50 >.50 your Cooper Lighting Representative. T.H.D. 120V 277V <35% <39% <94% <99% DIMENSIONS DESCRIPTION 12” [305mm] 21 11/16” [551mm] 8 7/16” [214mm] 9 7/8” [250mm] The CC Series Ultra High-Capacity Emergency Lighting Units are ideal for applications that demand the minimum cost but also require maximum flexibility, reliability and convenience in an attractive unit. CC9 CC10 CC11 CC12 Commercial 19” [483mm] The Contractor’s Choice FasTest™ Ultra High-Capacity Emergency Lighting Units are an affordable, yet attractive, alternative to standard two-headed emergency lighting units. All components snap together to facilitate installation in 5 minutes or less. Field versatility is not sacrificed for cost, both lighting heads offer horizontal and vertical adjustability. Moreover, proper operation of the transfer circuit and emergency lamps can be quickly and safely verified by using a convenient laser pointer (sold as an accessory). In addition, Watchguard EMS self diagnostic system is standard. EMERGENCY LIGHTS > SURE-LITES® C o n t r a c t o r ’s C h o i c e Ultra High Capacity EMERGENCY LIGHT Self-Diagnostics The self-diagnostic unit will automatically perform the tests required by the NFPA 101 Life Safety Code. The system indicates the status of the unit at all times using an LED indicator that is located near the test switch. Verify proper operation of the transfer circuit and emergency lamps with a convenient laser pointer (sold as an accessory). > Dual-Voltage Input 120/277 VAC, 60 Hz > Injection-Molded, Color-Stable, High-Impact UL 94-5V Rated Polycarbonate Housing and Mounting Plate > Designer white textured finish > Maintenance Free Sealed Lead Calcium Battery E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Model DC Voltage 1 1/2 Hours CC9SD CC10SD CC11SD CC12SD CC9SDMRT CC10SDMRT CC11SDMRT CC12SDMRT 12 12 12 12 12 12 12 12 160 200 240 300 160 200 240 300 Lamp Information Remote Capability 136W 176W 216W 276W 136W 176W 216W 276W Type Wattage Number Spacing1 Incandescent Incandescent Incandescent Incandescent MR16 MR16 MR16 MR16 12 12 12 12 12 12 12 12 029-132 029-132 029-132 029-132 029-141 029-141 029-141 029-141 24' 24' 24' 24' 50’ 50’ 50’ 50’ ea. ea. ea. ea. ea. ea. ea. ea. > Housing Has (8) Locations for Mounting of Heads; Consult Factory (3 optional bottom-mount and 3 optional top- mount locations) > Knockouts/Cutouts Provided in Housing for Surface Conduit Attachment > Watchguard EMS self diagnostic system O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: CC9SDMRT2142SM > Remote Photocell Test Switch with Automatic 30-Sec. Test Upon Switch Activation Model Number CC9SD CC10SD CC11SD CC12SD Options (Add as suffix) SQ=Square Head (12W Standard) MRT=MR16 Heads (12W Standard) Alternate Lamps - Specify quantity, lamp number (from Technical Information section) and mounting location (below), e.g. CC9SD2134SM319TM219BM SM=Side Mount Heads (2 lamp max.) TM=Top Mount Heads (3 lamp max.) BM=Bottom Mount Heads (3 lamp max.) Electrical Options A=Ammeter V=Voltmeter TDM- Time Daily Monitor CSK120=120V Cord Set CSK277= 277V Cord Set Other Options: Consult Cooper Lighting Representative Accessories (Order separately) LASER=Key Chain, Red Laser Pointer (activation tested at 30 feet) VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weather Resistant WG3=Wire Guard 2MSWH=Mounting Shelf > Line-Latching, Solid-State Voltage Limited Charger, Solid-State Switching, Low-Voltage Disconnect, Brownout Circuit, Overload/Short Circuit Protection, Push-Button Test Switch/Power Indicator Light > UL 924, Life Safety NFPA 101, NEC/OSHA, Most State and Local Codes 1 The "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 feet ceiling with a 6 feet wide walkway and 3 feet path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance. COOPER LIGHTING 25 Commercial EMERGENCY LIGHTS > SURE-LITES® DIMENSIONS DESCRIPTION The Sure-Lites CU1 unit represents the next generation of emergency lighting. Sure-Lites has combined dependable performance with a visually pleasing design. The PRESTO™ unit is designed to harmonize with today’s decor in commercial and public spaces. Injection molded from high impact thermoplastic. CU1 P R E STO ™ C o n te m p o ra r y Unit PRESTO™ is “contractor friendly.” The unique wiring module makes installation a snap. All AC wiring connections are made with the polarized wiring module and there is no need to juggle the unit in place. PRESTO™ may be ceiling or wall mounted, horizontally or vertically, and may be installed to a standard junction box or to surface mounted conduit. Long life battery and solid-state engineering provide trouble free operation. Two 5.4W wedge base incandescent lamps in locking specular reflectors appear to float in clear acrylic domes for distortion free lighting. Fully adjustable, locking lampheads with diffusing lens cover. EMERGENCY LIGHT > Dual-Voltage Input 120/277 VAC, 60 Hz Isolation Transformer > Designer white textured finish > Maintenance Sealed Lead Calcium Battery E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of rated D.C. Voltage Model CU1 CU1HD CU1NC CU1347 CU1HD347 Battery SLC2 SLC2 SNC3 SLC2 SLC2 DC Voltage 6 6 6 6 6 1 1/2 hours 10.8 22 11 10.8 22 2 hours 7.2 16 7.2 7.2 16 3 hours 11 11 Lamp Information Type Incandescent Incandescent Incandescent Incandescent Incandescent > Suitable for Wall or Ceiling Mount Applications. O R D E R I N G I N F O R M AT I O N > Universal J-Box Mounting Pattern. > Line-Latching, Solid-State Voltage Limited Charger, Solid-State Switching, Low-Voltage Disconnect, Brownout Circuit, Overload/Short Circuit Protection, Test Switch/ Power Indicator Light. SAMPLE NUMBER: CU1PCL Model Number CU1 CU1HD CU1NC CU1347 CU1HD347 > UL 924, Life Safety NFPA 101, CSA Certified, NEC/OSHA ,Most State and Local Codes. Options (Add as suffix) A=Ammeter B=Black Finish PCL=Polycarbonate Domes SD=Self-Diagnostics TDM=Time Delay Monitor V=Voltmeter Alternate Lamps1 (Wedge base & Krypton only) Other Options1 Accessories (Order separately) WG19 =Wire Guard VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weatherproof Energy Data Model No. CU1, CU1HD CU1NC CU13474 CU1HD3474 26 COOPER LIGHTING Input Current (Max.): 120V 277V 347V .12A .05A .06A .03A .14A .06A .18A .07A 1Consult your Cooper Lighting Representative. 2SLC=Sealed Lead Calcium 3SNC=Sealed Nickel Cadmium. 4347=347V for Canada. Wattage 5.4 5.4 5.4 5.4 5.4 Number 29-121 29-121 29-121 29-121 29-121 DIMENSIONS DESCRIPTION The CU2 emergency light is an economic, yet attractive, alternative to standard two headed emergency lighting units. All components snap together to facilitate installation in 2 minutes or less. 11 1/8" 11 1/8” [283mm] [283mm] 3 3/16 [81mm] The CU2 is ideal for applications which demand the minimum product cost without sacrificing dependability or aesthetics. Commercial CU2 5 3/8” [137mm] EMERGENCY LIGHTS > SURE-LITES® Contemporary Unit EMERGENCY LIGHT > Dual-Voltage Input 120/277 VAC, 60 Hz Isolation Transformer > High Impact polycarbonate Housing and Mounting Plate with Designer-White Textured finish E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Model CU2 CU22146 DC Voltage 6 6 1 1/2 Hours 10.8 10.8 Type Incandescent Krypton Wattage 5.4 5.4 SAMPLE NUMBER: CU2 CU2 Options (Add as suffix) V=Voltmeter CSK120=Cord Set (120 VAC) Alternate Lamps1 Other Options1 Energy Data Input Current (Max.): 120V=.12A 277V=.05A Number 029-121 029-146 > Suitable for Wall or Ceiling Mount Applications (including floor proximity installations) > Universal J-Box Mounting Pattern. O R D E R I N G I N F O R M AT I O N Model Number CU2 > Maintenance Sealed Lead Calcium Battery Lamp Information Accessories (Order separately) CAX18PKWH=18" Pendant Kit, White CAX18PKHTWH=18" Hang True Pendant Kit, White 1MSWH=Mounting Shelf, White VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weather Resistant WG1=Wire Guard > Line-Latching, Solid-State Voltage Limited Charger, Solid-State Switching, Low-Voltage Disconnect, Brownout Circuit, Overload/Short Circuit Protection, Test Switch/ Power Indicator Light. > Damp Location Listed Standard (CU-2 Only) > UL 924, Life Safety NFPA 101, CSA Certified, NEC/OSHA ,Most State and Local Codes. > ADA compliant 1Consult your Cooper Lighting Representative. COOPER LIGHTING 27 Commercial EMERGENCY LIGHTS > SURE-LITES® DESCRIPTION DIMENSIONS The XR Series is an efficient, rugged, commercial grade emergency light. The XR Series, in 6V and 12V models, has the extra capacity to power remote heads for added application flexibility. XR SERIES Steel EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz > 22 gauge die formed steel housing > White powder coat finish > White, high impact, thermoplastic > (2) fully adjustable thermoplastic heads - top mounted (side mounting optional) > Knockout, conduit or cord set > Universal J-box mounting pattern, keyhole slots > Remote capability > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed, CSA Certified, Life Safety NFPA 101, NEC/OSHA, most state and local codes E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of rated D.C. Voltage Model Number Lamp Information Battery DC Voltage 1 1/2 hours 2 hours 3 hours 4 hours SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SNC SNC SNC SNC SNC 6 6 6 6 6 6 6 12 12 12 12 6 6 6 12 12 27 27 27 36 54 54 54 36 54 36 54 15 24 50 30 50 24 24 24 30 48 48 48 30 48 30 48 12 18 36 24 36 18 16 18 20 36 36 36 20 36 20 36 8 14 28 18 28 14 14 14 16 28 28 28 16 28 16 28 6 10 20 14 20 XR3 XR33471 XR5 XR7 XR9 XR11 XR113471 XR122063471 XR122083471 XR12206 XR12208 XR15 XR16 XR17 XR20 XR21 Type Incandescent Incandescent Halogen Sealed Beam Incandescent Tungsten Halogen Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent SLC=Sealed Lead Calcium Battery SNC=Sealed Nickel Cadmium Battery O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: XR3TDM Model Number XR3 XR3347 XR5 XR7 XR9 XR11 XR11347 XR12206 XR12206347 XR12208 XR12208347 XR15 XR16 XR17 XR20 XR21 Options (Add as suffix) A=Ammeter MH=Metal Heads SD=Self-Diagnostics (XR3, XR5, XR12206, XR12208, XR15, XR16, XR20, XR21 Only) TDM=Time Delay Monitor V=Voltmeter Alternate Lamps 2 Other Finishes 2 Other Options 2 Accessories (Order separately) 1BRWH =Mounting Brackets (2-White Finish) 1MSWH=Mounting Shelf (White Finish) VK1 =Voltmeter CSK120=Cord Set 120VAC CSK277=Cord Set 277VAC WG1=Wire Guard VS2=Polycarbonate Vandal Shield VS2WP=Polycarbonate Vandal Shield Weatherproof Energy Data Model No. XR3, XR5, XR7, XR9, XR11 XR12206, XR12208 XR15 XR16 XR17 XR20 XR21 28 COOPER LIGHTING Input Current (Max.): 120V 277V .12A .05A .30A .13A .06A .03A .07A .04A .08A .05A .13A .06A .15A .07A Note: 0, 1, 3 & 4 Heads also available. Specify after catalog number [i.e., XR11484 = (XR11) with (4) 029-84 Lamps]. 1347=120/347V 2Consult your Cooper Lighting Representative. Wattage 9 9 6 9 6 9 9 9 9 9 9 7.2 7.2 7.2 9 9 29-84 29-84 29-37 29-84 29-12 29-84 29-84 29-86 29-86 29-86 29-86 29-88 29-88 29-88 29-86 29-86 DIMENSIONS DESCRIPTION A real workhorse in emergency lighting systems. These durable, reliable units are unparalleled in both performance and freedom from maintenance. A B C D E F G H High Capacity Ultra High Capacity 12 1/4” (311mm) 13 1/4” (337mm) 7 7/8” (200mm) 4 1/4” (108mm) 4 3/4” (121mm) 1 3/8” (35mm) --------------------------------------------- 17” (432mm) 16 7/8” (429mm) 11 1/2” (292mm) 8” (203mm) 6” (152mm) 2” (51mm) 5 3/4” (146mm) 2 1/2” (64mm) HR SERIES Commercial The HR Series provide a low cost, solid-state lighting system ideal for industrial, commercial or multi-housing environments. High capacity makes the HR Series ideal for installations where a large number of heads/exits will be remotely operated. EMERGENCY LIGHTS > SURE-LITES® H i g h C a p a c i t y, 8 7 - 11 7 W a t t s Ultra-High Capacity 17 0 - 3 6 0 Wa tt s EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz > 18 gauge die formed steel housing and cover > White powder coat finish E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of rated D.C. Voltage Model DC Voltage 1 1/2 hours High Capacity HR87* 6 87 HR117* 6 117 HR12117* 12 117 HR12117347*1 12 117 Ultra High Capacity HR180* 6 HR12170* 12 HR12210* 12 180 170 210 2 hours 3 hours 65 87 87 87 43 58 58 58 135 128 157 90 85 105 4 hours 32 43 43 43 67 64 78 Lamp Information Type Wattage Number Incandescent Incandescent Incandescent Incandescent 9 9 9 9 29-84 29-84 29-86 29-86 Incandescent 9 Incandescent 9 Incandescent 9 29-84 29-86 29-86 *Batteries may be shipped separately. O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: HR87TDM Model Number HR87 HR117 HR12117 HR180 HR12170 HR12210 HR12360 Options (Add as suffix) A=Ammeter TDM=Time Delay Monitor V=Voltmeter Alternate Lamps 2 Other Options 2 Other finishes2 MH=Metal heads Accessories (Order separately) VK1 =Voltmeter 3BRWH =Mounting Brackets 2MSWH =Mounting Shelf (High Capacity) 3MSWH =Mounting Shelf (Ultra High Capacity) WG3=Wire Guard (Ultra High Capacity) WG7=Wire Guard (High Capacity) CSK120=Cord Set (120VAC) CSK277=Cord Set (277VAC) VS2=Polycarbonate Vandal Shield VS2WP=Polycarbonate Vandal Shield - Weatherproof > Two top mounted, fully adjustable, white, highImpact thermoplastic heads > Sealed lead-calcium battery > Knockout, conduit or cord set > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light > UL 924 Listed, CSA Certified, Life Safety NFPA 101, NEC/OSHA, most state and local codes Energy Data Model No. HR87 HR117 HR12117 HR12117347 HR180 HR12170 HR12210 HR12360 Input Current (Max.): 120V 277V .50A .21A .53A .22A .26A .13A .25A — .98A .43A 1.08A .45A 1.02A .47A 1.17A .54A 347V .60A Note: 0, 1, 3 & 4 Heads also available. Specify after catalog number [i.e., HR12117379 = (HR12117) with (3) 29-79 Lamps]. 1347=120/347V 2Consult your Cooper Lighting Representative. COOPER LIGHTING 29 DESCRIPTION DIMENSIONS The HS1R emergency lighting unit provides emergency lighting when you need it most. The fixture’s unique design makes it adaptable to many applications. HS1R SERIES Po rt a b l e EMERGENCY LIGHT with 6’ Cord & Plug > Quick installation (2 minutes) > 120VAC 60Hz 6.0” [151mm] 5.0” [128mm] The HS1R can be used as a free standing unit or it can be wall mounted using the keyhole slots provided. A 6-foot cord and plug are provided for ease of AC power hook-up. The integral handle allows the HS1R to become portable during power loss when mobility is necessary. 6.5” [168mm] 7.0” [177mm] Commercial EMERGENCY LIGHTS > SURE-LITES® 3.0” [75mm] Two PAR20 style heads allow total horizontal and vertical aiming adjustability. The lamp head selection switch allows the choice for 1 lamp illumination for 4 hours or 2-lamp illumination for 2 hours. > Injection molded, color stable, high impact polycarbonate housing > Designer white textured finish E L E C T R I C A L R AT I N G S > Lamp Selection Switch for 1 or 2 lamp operation Model DC Voltage HS1R 6 Rated Wattage to 87 1/2% of Rated D.C. Voltage 1 1/2 Hours 10.8 > Suitable for wall mount applications > Keyhole mounting slots > Solid State Voltage Limited Charger, Brownout Circuit, Test Switch/Power Indicator Light > UL 924 Listed, Auxiliary Equipment, CSA Certified, NEC/OSHA, Meets most State and Local Codes 30 COOPER LIGHTING O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: HS1R HS1R Model Number HS1R Accessories (order separately) 1BRWH=Mounting Brackets (2-White Finish) 1MSWH=Mounting Shelf (White Finish) Lamp Information Type Incandescent Wattage 5.4 Number 029-121 DIMENSIONS DESCRIPTION The LM Series is an emergency light packaged in an attractive, flame-resistant metal housing. High-impact thermoplastic PAR36 heads permit unrestricted unit placement and easy beam positioning. LM1 SERIES Commercial The unit of choice for installations where the size and cost of emergency lighting must be kept to a minimum without sacrificing dependability or light output. EMERGENCY LIGHTS > SURE-LITES® Steel EMERGENCY LIGHT E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of rated D.C. Voltage Lamp Information Model DC Voltage 1 1/2 hours 2 hours Type LM1 6 7.2 Incandescent 5.4 10.8 Wattage Number > Dual-voltage input 120/277VAC, 60Hz 029-121 > 18 gauge die formed steel housing > White powder coat finish O R D E R I N G I N F O R M AT I O N > Two PAR36 type lamps in fully adjustable, white, high-impact thermoplastic lampholders SAMPLE NUMBER: LM1V LM1 Model Number LM1 Options (Add as suffix) V=Voltmeter Alternate Lamps1 Other Finishes1 Other Options1 Energy Data Input Current (Max.): Model No. LM1 1Consult 120V .12A 277V .05A Accessories (Order separately) 1BRWH =Mounting Brackets (2) White VK1=Voltmeter CSK120=Cord Set 120VAC CSK277=Cord Set 277VAC WG2 =Wire Guard VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weatherproof > Sealed lead calcium battery > Knockout, conduit or cord set > Universal J-box mounting pattern, keyhole slots > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes your Cooper Lighting Representative. COOPER LIGHTING 31 Commercial EMERGENCY LIGHTS > SURE-LITES® DIMENSIONS DESCRIPTION A versatile “mini-system” featuring reliability, quality metal construction, optimum illumination and an attractive compact appearance. The popular choice for commercial, institutional and public facilities where moderate loads, economy, ease of installation, safety and reliability are important. AA1 SERIES Steel EMERGENCY LIGHT > Dual-voltage input 120/277VAC, 60Hz E L E C T R I C A L R AT I N G S > 22 gauge die formed steel housing Model Battery DC Voltage 1 1/2 hours 2 hours 3 hours 4 hours Type Wattage Number AA1 AA8 SLC3 SNC4 6 6 18 15 15 12 10 8 8 6 Incandescent Incandescent 9 7.2 29-84 29-88 Rated Wattage to 87 1/2% of rated D.C. Voltage Lamp Information > White powder coat finish > Two PAR36 type lamps in fully adjustable, white, high-impact thermoplastic lampholders O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: AA1SD > Sealed nickel cadmium battery > Knockout, conduit or cord set Model Number AA1 AA8 > Universal J-box mounting pattern, keyhole slots > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes Input Current 1Consult COOPER LIGHTING Accessories (Order separately) 1BRWH =Mounting Brackets (2) White 1MSWH=Mounting Shelf, White VK1=Voltmeter WG1 =Wire Guard CSK120=Cord Set (120VAC) CSK277=Cord Set (277VAC) VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weatherproof Energy Data (Max.): Model No. AA1 AA8 32 Options (Add as suffix) A=Ammeter 2 SD=Self-Diagnostics TDM=Time Delay Monitor V=Voltmeter 2 Alternate Lamps 1 Other Finishes 1 Other Options 1 120V .12A .06A 277V .05A .03A your Cooper Lighting Representative. 2Provision for one meter only. 3SLC=Sealed Lead Calcium 4SNC=Sealed Nickel Cadmium DESCRIPTION O R D E R I N G I N F O R M AT I O N 6 Volt Universal Remote Heads Catalog No. Lamp Type Volts Watts Lamp No. 6T6XXU* 6T8XXU* 6T12XXU* 6X54XXU* 6X7XXU* 6X9XXU* 6X12XXU* 6X25XXU* 6 6 6 6 6 6 6 6 6 8 12 5.4 7 9 12 25 029-37 029-14 029-15 029-121 029-88 029-84 029-39 029-09 Halogen Sealed Beam Halogen Sealed Beam Halogen Sealed Beam Incandescent Wedge Base Incandescent Wedge Base Incandescent Wedge Base Incandescent Sealed Beam Incandescent Sealed Beam Catalog No. Lamp Type Volts Watts Lamp No. 12T8XXU* 12T12XXU* 12X9WHU* 12X12XXU* 12X25XXU* Halogen Sealed Beam Halogen Sealed Beam Incandescent Wedge Base Incandescent Sealed Beam Incandescent Sealed Beam 12 12 12 12 12 8 12 9 12 25 029-16 029-79 029-86 029-26 029-08 Finish Codes: WH-White, BK-Black, GY-Grey. Replace “XX” with desired Finish Code when ordering. (Example: 6T12WHU, for double head: 6T12DWH). Alternate Lamps 1 *Remove “U”, Add “RD” suffix for Roundback Heads; Add “SQ” suffix for Square Heads - RD & SQ Heads available in white only; SQ Head only available in wedge base and bi-pin lamps. (Example: GX7WHSQ) Remote 12 Volt Universal Heads Flame and impact resistant injection molded thermoplastic PAR36 type lampholders. Available in White, Grey and Black finishes (specify color when ordering.) Heads adjust 80° from vertical with 358° rotation. Supplied complete with thermoplastic lampholder housings, swivel, lamp and 5" diameter mounting plate. Universal mounting plate has three knockouts for mounting lampholders on either side or in center position. For double head remotes, specify two Universal Remote Head Assemblies. UL 924 Listed, CSA certified. EMERGENCY LIGHTS > SURE-LITES® 6V, 12V PLASTIC REMOTES Universal Remote Heads SQ Heads Option RD Heads Option DESCRIPTION O R D E R I N G I N F O R M AT I O N 6 Volt Single Head Weatherproof Remotes Catalog No. Lamp Type 6T6WXX Halogen Sealed Beam 6T8WXX Halogen Sealed Beam 6X7WXX Incandescent Sealed Beam 6X9WXX Incandescent Sealed Beam 6XW54WXX Incandescent Wedge Base 6XW7WXX Incandescent Wedge Base 6XW9WXX Incandescent Wedge Base Volts 6 6 6 6 6 6 6 Watts 6 8 7.2 8 5.4 7.2 9 Lamp No. 029-37 029-14 029-75 029-03 XW029-121 XW029-88 XW029-84 6 Volt Double Head Weatherproof Remotes Catalog No. Lamp Type 6T6DWXX Halogen Sealed Beam 6T8DWXX Halogen Sealed Beam 6X7DWXX Incandescent Sealed Beam 6X9DWXX Incandescent Sealed Beam 6XW54DWXX Incandescent Wedge Base 6XW7DWXX Incandescent Wedge Base 6XW9DWXX Incandescent Wedge Base Volts 6 6 6 6 6 6 6 Watts 6 8 7.2 8 5.4 7.2 9 Lamp No. 029-37 029-14 029-75 029-03 XW029-121 XW029-88 XW029-84 12 Volt Single Head Weatherproof Remotes Catalog No. Lamp Type 12T8WXX Halogen Sealed Beam 12T12WXX Halogen Sealed Beam 12X25WXX Incandescent Sealed Beam 12XW9WXX Incandescent Wedge Base 12XW12WXX Incandescent Wedge Base Volts 12 12 12 12 12 Watts 8 12 25 9 12 Lamp No. 029-16 029-79 029-08 XW029-86 XW029-132 12 Volt Double Head Weatherproof Remotes Catalog No. Lamp Type 12T8DWXX Halogen Sealed Beam 12T12DWXX Halogen Sealed Beam 12X25DWXX Incandescent Sealed Beam 12XW9DWXX Incandescent Wedge Base 12XW12DWXX Incandescent Wedge Base Volts 12 12 12 12 12 Watts 8 12 25 9 12 Lamp No. 029-16 029-79 029-08 XW029-86 XW029-132 Finish Codes: WH-White, GY-Grey , BK-Black. Replace “XX” with desired Finish Code when ordering. (Example: 6T6DWWH). Designed to perform in wet locations. Flame and impact resistant injection molded thermoplastic PAR36 lampholders. Die cast, aluminum gasketed mounting plate. Sealed swivel and coated lamp terminals resist oil, water and dust. Available in standard industrial white, grey and black finishes (specify color when ordering). Heads adjust 80° from vertical with 358° rotation. Supplied complete with thermoplastic lampholder housings, swivel, lamp and 5" diameter die cast, grey mounting plate. UL 924 Listed, CSA Certified. UL Wet Location Listed. 6V, 12V PLASTIC WEATHERPROOF REMOTES Single and Double Remote Heads Alternate Lamps 1 1Consult your Cooper Lighting Representative. COOPER LIGHTING 33 DESCRIPTION EMERGENCY LIGHTS > Remote SURE-LITES® Lamp housing is made of corrosion resistant 22 gauge die formed spun aluminum with a powder coat finish. Die cast aluminum swivel assembly allows 80° adjustment from vertical with 358° rotation. Stainless steel mounting plate mounts flush on wall or ceiling and is designed for installation on standard electrical box. (Single head remotes are supplied with single gang plate, double head remotes are supplied with three gang plate). UL 924 Listed, CSA Certified. 6V, 12V METAL HEAD REMOTES Catalog No. Lamp Housing + Mounting Plate Finish Lamp Type Volts Watts Lamp No. Halogen Sealed Beam Halogen Sealed Beam Incandescent Sealed Beam 6 6 6 6 12 7.2 029-37 029-15 029-75 6 Volt Double Metal Head Remotes 6T6DMHWH White 6T12DMHWH White Halogen Sealed Beam Halogen Sealed Beam 6 6 6 12 029-37 029-15 12 Volt Single Metal Head Remotes 12T12MHWH White 12T50MHWH White Halogen Sealed Beam Halogen Sealed Beam 12 12 12 50 029-79 029-135 12 Volt Double Metal Head Remotes 12T12DMHWH White 12T50DMHWH White Halogen Sealed Beam Halogen Sealed Beam 12 12 12 50 029-79 029-135 6 Volt Single Metal Head Remotes 6T6MHWH White 6T12MHWH White 6X7MHWH White Alternate Lamps 1 Other Finishes 1 Single and Double Remote Heads DESCRIPTION 6V, 12V WEATHERPROOF METAL HEAD REMOTES O R D E R I N G I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N 6 Volt Single Metal Weatherproof Designed to perform in wet Catalog Heads Lamp Type locations. Lamp housing is One Incandescent - Sealed Beam made of corrosion resistant 22 6X7WMHWH 6X8WMHWH One Incandescent - Sealed Beam gauge die formed spun alu6X12WMHWH One Incandescent - Sealed Beam minum with a powder coat fin- 6X18WMHWH One Incandescent - Sealed Beam ish and a die cast aluminum, 6X25WMHWH* One Incandescent - Sealed Beam 6T6WMHWH One Halogen - Sealed Beam gasketed mounting plate. 6T8WMHWH One Halogen - Sealed Beam Sealed swivel and coated 6T10WMHWH One Halogen - Sealed Beam lamp terminals resist oil, water 6T12WMHWH* One Halogen - Sealed Beam and dust. Available in standard 6T20WMHWH* One Halogen - Sealed Beam industrial white finish-specify 6XW54WMHWH One Wedge Base - Incandescent One Wedge Base - Incandescent color when ordering; other fin- 6XW7WMHWH 6XW9WMHWH One Wedge Base - Incandescent ishes available. Heads adjust 80° from vertical with 358° 12 Volt Single Metal Weatherproof Catalog Heads Lamp Type rotation. Supplied complete 12X12WMHWH One Incandescent - Sealed Beam with a 5" diameter die cast, One Incandescent - Sealed Beam grey finished, gasketed mount- 12X18WMHWH 12X25WMHWH* One Incandescent - Sealed Beam ing plate. UL 924 Listed, CSA 12X30WMHWH* One Incandescent - Sealed Beam Certified. City of Chicago Code 12T8WMHWH One Halogen - Sealed Beam (see catalog numbers with*), 12T12WMHWH* One Halogen - Sealed Beam 12T37WMHWH* One Halogen - Sealed Beam UL Wet Location Listed. 12T50WMHWH* 12XW9WMHWH 12XW12WMHWH One One One Halogen - Sealed Beam Wedge Base - Incandescent Wedge Base - Incandescent Volts 6 6 6 6 6 6 6 6 6 6 6 6 6 Watts 7 8 12 18 25 6 8 10 12 20 5.4 7.2 9 Lamp Number 029-75 029-03 029-39 029-13 029-09 029-37 029-14 029-36 029-15 029-18 029121 02988 02984 Volts 12 12 12 12 12 12 12 12 12 12 Watts 12 18 25 30 8 12 37.5 50 9 12 Lamp Number 029-26 029-19 029-08 029-126 029-16 029-79 029-134 029-135 02986 029132 Volts 6 6 6 6 6 6 6 6 6 6 6 6 6 Watts 7 8 12 18 25 6 8 10 12 20 5.4 7.2 9 Lamp Number 029-75 029-03 029-39 029-19 029-09 029-37 029-14 029-36 029-15 029-18 029121 02988 02984 Volts 12 12 12 12 12 12 12 12 12 12 Watts 12 18 25 30 8 12 37.5 50 9 12 Lamp Number 029-26 029-19 029-08 029-126 029-16 029-79 029-134 029-135 02986 029132 6 Volt Double Metal Weatherproof Catalog 6X7DWMHWH 6X8DWMHWH 6X12DWMHWH 6X18DWMHWH 6X25DWMHWH* 6T6DWMHWH 6T8DWMHWH 6T10DWMHWH 6T12DWMHWH* 6T20DWMHWH* 6XW54DWMHWH 6XW7DWMHWH 6XW9DWMHWH Single and Double Remote Heads Heads Two Two Two Two Two Two Two Two Two Two Two Two Two Lamp Type Incandescent - Sealed Beam Incandescent - Sealed Beam Incandescent - Sealed Beam Incandescent - Sealed Beam Incandescent - Sealed Beam Halogen - Sealed Beam Halogen - Sealed Beam Halogen - Sealed Beam Halogen - Sealed Beam Halogen - Sealed Beam Wedge Base - Incandescent Wedge Base - Incandescent Wedge Base - Incandescent 12 Volt Double Metal Weatherproof Catalog Notes: WH – White (standard finish), GY – Grey, BK – Black * Meets City of Chicago Code 1Consult 34 COOPER LIGHTING your Cooper Lighting Representative. Catalog 12X12DWMHWH 12X18DWMHWH 12X25DWMHWH* 12X30DWMHWH* 12T8DWMHWH 12T12DWMHWH* 12T37DWMHWH* 12T50DWMHWH* 12XW9DWMHWH 12XW12DWMHWH Heads Two Two Two Two Two Two Two Two Two Two Lamp Type Incandescent - Sealed Beam Incandescent - Sealed Beam Incandescent - Sealed Beam Incandescent - Sealed Beam Halogen - Sealed Beam Halogen - Sealed Beam Halogen - Sealed Beam Halogen - Sealed Beam Wedge Base - Incandescent Wedge Base - Incandescent DESCRIPTION O R D E R I N G I N F O R M AT I O N 6 Vo l t S i n g l e H e a d M R 1 6 R e m o t e H e a d s Catalog No. Lamp Type Volts Watts Lamp No. MRT6T5 MR16 6 5 029-139 MRT6T9 MR16 6 9 029-143 MRT6T12 MR16 6 12 029-140 6 Vo l t D o u b l e H e a d M R 1 6 R e m o t e H e a d s Lamp Type Volts Watts Lamp No. MRT6T5D MR16 6 5 029-139 MRT6T9D MR16 6 9 029-143 MRT6T12D MR16 6 12 029-140 1 2 Vo l t S i n g l e H e a d M R 1 6 R e m o t e H e a d s Catalog No. Lamp Type Volts Watts Lamp No. MRT12T12 MR16 12 12 029-141 MRT12T20 MR16 12 20 029-142 MRT12T50 MR16 12 50 029-144 Remote Catalog No. The MR16 Remote includes a steel gimbal ring and arm with a glass lens and an injection molded thermoplastic canopy. Available in White only. Heads adjust 80° from vertical with 358° rotation. Supplied complete with gimbal ring assembly, MR16 lamping, glass lens, and 5” diameter mounting plate. MR16 gimbal ring assemblies come pre-mounted to canopy in single and double head configurations. Use WG8 Wire Guard for single head remotes; and WG9 Wire Guard for double head remotes. UL Listed, Life Safety NFPA 101. EMERGENCY LIGHTS > SURE-LITES® MR16 SERIES Single and Double Remote Heads 1 2 Vo l t D o u b l e H e a d M R 1 6 R e m o t e H e a d s Catalog No. Lamp Type Volts Watts Lamp No. MRT12T12D MR16 12 12 029-141 MRT12T20D MR16 12 20 029-142 MRT12T50D MR16 12 50 029-144 DESCRIPTION The Metrolite MR Series are 6V or 12V DC remotes that provide continuity in style when used with the ML Series. The MR Series sculptured and compact appearance makes it perfect for high quality interior applications. The self-contained, feature rich design packs a powerful punch with its super-bright halogen lamp and precision optics. The integral mounting plate makes installation fast and easy. UL listed. O R D E R I N G I N F O R M AT I O N Single Head Remotes Catalog No. Lamp Type MR6T12 Bi-Pin Halogen MR12T12 Bi-Pin Halogen DC Voltage 6 12 Watts 12 12 Lamp No. 029-66 029-45 Double Head Remotes Catalog No. Lamp Type MR6T12D Bi-Pin Halogen MR12T12D Bi-Pin Halogen DC Voltage 6 12 Watts 12 12 Lamp No. 029-66 029-45 Alternate Lamps 1 MR SERIES Single and Double Remote Heads 1Consult your Cooper Lighting Representative. COOPER LIGHTING 35 Remote EMERGENCY LIGHTS > SURE-LITES® O R D E R I N G I N F O R M AT I O N DESCRIPTION Single Head Remotes Catalog No. CFR103 CFR116 CFR Matches SLC Series emergency lighting units. Lamp heads adjust 80° from vertical with 358° rotation. Die-formed steel faceplate has a white, corrosion-resistant finish. Cabinet has side knockout for conduit connection as well as universal pattern mounting knockouts. UL listed. Lamp Type Incandescent Sealed Beam Halogen Sealed Beam Volts 6 12 Watts 8 8 Lamp No. 029-03 029-16 Lamp Type Incandescent Sealed Beam Halogen Sealed Beam Volts 6 12 Watts 8 8 Lamp No. 029-03 029-16 Double Head Remotes Catalog No. CFR203 CFR216 Alternate Lamps 1 CFR SERIES CYLINDER REMOTES Single and Double Head Remotes DESCRIPTION DR SERIES DR Matches RD Series emergency lighting units. Heads are injection molded high gloss thermoplastic. Lamp heads adjust 80° from vertical with 358° rotation. Single head remotes supplied with single gang mounting plate, double head remotes supplied with three gang mounting plate. UL listed. O R D E R I N G I N F O R M AT I O N Single Head Remotes Catalog No. Finish DR112 White DR166 White DR145 White Lamp Type Halogen Bi-Pin T2 1/4 Halogen Bi-Pin T2 1/4 Halogen Bi-Pin T2 1/4 Volts 6 6 12 Watts 6 12 12 Lamp No. 029-12 029-66 029-45 Lamp Type Halogen Bi-Pin T2 1/4 Halogen Bi-Pin T2 1/4 Halogen Bi-Pin T2 1/4 Volts 6 6 12 Watts 6 12 12 Lamp 029-12 029-66 029-45 Volts 6 6 Watts 5.4 5.4 Lamp No. 029-121 029-121 Volts 6 12 Watts 8 8 Lamp No. 029-03 029-16 Double Head Remotes Catalog No. DR212 DR266 DR245 Finish White White White Alternate Lamps 1 DESIGNER REMOTES Single and Double Head Remotes CU1 SERIES SPECIALTY REMOTES DESCRIPTION O R D E R I N G I N F O R M AT I O N CU1R Matches CU1 Series Emergency lighting units. For use with CU1HD emergency lighting unit or 6V DC Class 2 circuit. Clear acrylic dome (for polycarbonate dome, add PCL suffix to catalog number). UL listed CU1R Series Catalog No. CU1R CU1RB DESCRIPTION O R D E R I N G I N F O R M AT I O N GFR Matches RG1 Series emergency lighting units. 20 gauge die-stamped steel housing with white baked-enamel finish. Available with 6 volt or 12 volt incandescent sealed beam lamps. UL 924 damp location listed. GFR Series Catalog No. GFR2703 GFR2716 Finish White Black Lamp Type Incandescent Wedge Base Incandescent Wedge Base Alternate Lamps 1 Other Finishes 1 Single Head Remotes GFR SERIES SPECIALTY REMOTES Alternate Lamps 1 Other Finishes 1 Single Head Remotes 36 1Consult COOPER LIGHTING your Cooper Lighting Representative. Finish White Trim White Trim Lamp Type Incandescent Sealed Beam Halogen Sealed Beam DESCRIPTION R4C Matches P4C Series emergency lighting units. Impact resistant thermoplastic housing is UL924 rated. Black thermoplastic body with white plastic collar and reflector. For semi-recessed installation, order USF1 accessory. For fully recessed installation, order FRK1 accessory. O R D E R I N G I N F O R M AT I O N R4C Series Catalog No. R4C140 R4C145 Lamp Type Halogen Bi-Pin T2 1/4 Halogen Bi-Pin T2 1/4 Volts 6 12 Watts 10 12 Lamp No. 029-40 029-45 R4C SERIES Emergency Remotes Remote Alternate Lamps 1 Other Finishes 1 EMERGENCY LIGHTS > SURE-LITES® DESCRIPTION RFR 20 gauge die-stamped steel housing with white baked enamel finish. 5 1/2" housing accommodates 2x6 joist construction. Available with 6 volt or 12 volt incandescent double contact bayonet base lamps. UL Damp Location Listed. O R D E R I N G I N F O R M AT I O N RFR Series Catalog No. RFR130 RFR153 Finish White Trim White Trim Lamp Type Incandescent DC Bayonet Base Incandescent DC Bayonet Base Volts 6 12 Watts 6.6 7.5 Lamp No. 029-30 029-53 RFR SERIES Alternate Lamps 1 Other Finishes 1 Emergency Remotes DESCRIPTION ULTIMATE REMOTE HEAD The Sure-Lites Ultimate Series explosion-proof, emergency lighting fixtures are designed for remote mounting in Class I, Division II Group A, B, C, and D locations such as oil refineries, oil and gasoline loading docks, chemical and petrochemical plants, paint manufacturing sites, pumping stations and other process industry facilities where similar hazards threaten. UL 844 listed. UL 924 wet location listed. O R D E R I N G I N F O R M AT I O N - C L A S S I , D I V I S I O N I I , G R O U P S A , B , C , D ( U L 8 4 4 H A Z A R D O U S L I ST E D ) Catalog Number Lamp Type Volts Watts Lamp No. T-Code Lamp Data MRT6T5HAZ MRT6T9HAZ MRT6T12HAZ MRT12T12HAZ MRT12T20HAZ MR16 MR16 MR16 MR16 MR16 6 6 6 12 12 5 9 12 12 20 029-139 029-143 029-140 029-141 029-142 T3A T2C T2A T2A T1 ADX031520 ADX031520 ADX031520 ADX031520 ADX031520 O R D E R I N G I N F O R M AT I O N - W E T L O C AT I O N ( U L 9 2 4 W E T LO C AT I O N L I ST E D ) ULTIMATE REMOTE SERIES Emergency Remotes Catalog Number Lamp Type Volts Watts Lamp No. Lamp Data MRT6T5W MRT6T9W MRT6T12W MRT12T12W MRT12T20W MRT12T50W MR16 MR16 MR16 MR16 MR16 MR16 6 6 6 12 12 12 5 9 12 12 20 50 029-139 029-143 029-140 029-141 029-142 029-144 ADX031520 ADX031520 ADX031520 ADX031520 ADX031520 ADX031520 DESCRIPTION HZB/HZP The Sure-Lites HZP Series and HZB Series explosion-proof, emergency lighting fixtures are designed for remote mounting in Class I, Division 1, Group C, D and Class II, Division 1, Group E, F, G locations such as oil refineries, oil and gasoline loading docks, chemical and petrochemical plants, paint manufacturing sites, pumping stations and other process industry facilities where similar hazards exist. Body and globe guard are copper-free, corrosion resistant light weight aluminum, with a heat and impact resistant glass globe. UL 924 Listed, Life Safety NFPA 101, NEC Class I, division 1, Groups C, D and Class II, Division 1, Groups E, F, G, NEC/OSHA, most state and local codes. UL Damp Location Listed. HZB/HZP SERIES O R D E R I N G I N F O R M AT I O N HZ Series Catalog No. 12X25HZP 12X25HZB 1Consult Mounting Pendant Bracket Lamp Type Incandescent Incandescent Volts 12 12 Watts 25 25 Lamp No. ZZ-13 ZZ-13 Emergency Remotes your Cooper Lighting Representative. COOPER LIGHTING 37 DESCRIPTION EXIT SIGNS > Architectural SURE-LITES® ELX SERIES DIMENSIONS The Sure-Lites ELX Series Recessed Exits are designed for architectural excellence and minimal presence. The crystal clear wedge shaped panel allows architectural details to shine through while providing excellent light distribution and exit visibility. Long life, energy-efficient LED lamps reduce energy costs and eliminate routine lamp maintenance. Edge-Lit AC Only Recessed EXIT LIGHTING > Dual Voltage Input 120/277 VAC or 120/347 VAC 60 Hz > 20 gauge recessed steel housing with nine conduit knockouts > Recessed housing may be ordered separately2 > Injection molded highimpact acrylic panel > LED or Fluorescent Lamping > Fluorescent: Two F8T5 lamps wired for separate circuits *Fluorescent Only (LED=3 3/4”) O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : E L X 4 10 0 R M A R E ELX Factory Options Blank=None 95=AC Only Fire Alarm Interface (LED ONLY) Family ELX=Edgelit Exit Series Series 4=AC Only, Fluorescent 6=LED Lamps, AC Only Face Options 1=Single Face 2=Double Face Battery 00=No Battery > Mirror and white inserts provided standard with all exits Letter Color1 R=Red G=Green Mounting Options C=Ceiling W=Wall E=End Options 2C=Two Circuit Option-FTBR (LED Only) Accessories (Order Separately) 277V Conversion Kit CAN277ELX=277V Transformers, Mounting Hardware (fluorescent only) C H E V R O N C O N F I G U R AT I O N > Damp Location Listed > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes UL FTBR Listed - Standard Fluorescent, LED with 2C Option Voltage Blank=120V (fluorescent only) 7=277V (fluorescent only) Blank=Dual-voltage 120/277V (LED Only) 47=120/347V (LED Only) Chevron Direction Blank=No Chevron AR=Right Chevron AL=Left Chevron DA=Double Chevron ARL=Chevrons Right/Left (Double Face Only) > Universal Background (Field selectable: clear, mirror or white) > Molded letters and chevrons improve aesthetic appearance and increase visibility Trim Finish Blank=Brushed Aluminum WH=White BL=Black BZ=Bronze BS=Brass CR=Chrome FRONT BACK FACE AR . . . . . . . . . . . . . . . . . . . EXIT> AL . . . . . . . . . . . . . . . . . . .DA . . . . . . . . . . . . . . . . . . ARL . . . . . . . . . . . . . . . . . EXIT> Blank Blank Blank .56 >.30 — >10% >11% — >.34 >.73 >.19 >.15 >.34 >.28 <35% <19% <17% <50% <30% <26% your Cooper Lighting Representative. DIMENSIONS DESCRIPTION Architectural The Sure-Lites ELX Series Recessed Exits are designed for architectural excellence and minimal presence. The crystal clear wedge shaped panel allows architectural details to shine through while providing excellent light distribution and exit visibility.Long life, energy-efficient LED lamps reduce energy costs and eliminate routine lamp maintenance. EXIT SIGNS > SURE-LITES® ELX SERIES Edge-Lit S e l f - Powe re d *Fluorescent Only (LED=3 3/4”) Recessed EXIT LIGHTING O R D E R I N G I N F O R M AT I O N > Dual-voltage input 120/277 VAC or 120/347 VAC 60Hz SAMPLE NUMBER: ELX5170RARE ELX Factory Options (LED EXITS ONLY) Blank=None 90=DC Only Fire Alarm Interface Family ELX=Edgelit Exit Series Series 5=Self-Powered, Fluorescent 7=Self-Powered, LED Lamps Trim Finish Blank=Brushed Aluminum WH=White BL=Black BZ=Bronze BS=Brass CR=Chrome Face Options 1=Single Face 2=Double Face Battery 70=Nickel Cadmium Letter Color1 R=Red G=Green Chevron Direction Blank=No Chevron AR=Right Chevron AL=Left Chevron DA=Double Chevron ARL=Chevrons Right/ Left (Double Face Only) > 20 gauge steel recessed housing with nine conduit knockouts Voltage Blank=120/277V Dual-voltage 47=120/347V (LED Exits Only) > Recessed housing may be ordered separately2 > Injection molded highimpact acrylic panel Mounting Options C=Ceiling W=Wall E=End > LED or Fluorescent lamping SD=Self-Diagnostics (LED EXITS ONLY) > Fluorescent: two F8T5 lamps wired for separate circuits Accessories (Order Separately) (LED EXITS ONLY) Laser=Key Chain, Red Laser Pointer (activation tested at 30 feet. > Premium Nickel Cadmium battery > Watchguard EMS Self-Diagnostic System (Standard) > Universal Background (Field selectable: clear, mirror or white) > Mirror and white inserts provided standard with all exits C H E V R O N C O N F I G U R AT I O N FRONT BACK FACE AR . . . . . . . . . . . . . . . . . . . EXIT> AL . . . . . . . . . . . . . . . . . . . DA . . . . . . . . . . . . . . . . . . ARL . . . . . . . . . . . . . . . . . EXIT> Blank Blank Blank Molded letters and chevrons improve aesthetic appearance and increase visibility Energy Data Input Power: 120V 277V 347V Input Current (Max.): Power Factor: 120V 277V 347V 120V 277V 347V Fluorescent Exits Fluorescent Exits -8W Lamps 14W 14W .21A .09A >.56 >.58 LED Exits with Self-Diagnostics Option LED Exits -Red Letters 4.9W 4.8W .05A .02A >.90 >.87 LED Exits - Green Letters 4.9W 4.7W .05A .02A >.85 >.82 - 1Mirror insert installed standard. White insert shipped in carton. 2Consult your Cooper Lighting Representative. T.H.D.: 120V 277V 347V <12% <12% - <25% <24% <25% <24% - > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light. > Damp Location Listed > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes COOPER LIGHTING 39 DESCRIPTION DIMENSIONS The Sure-Lites ES Series Exits are designed for architectural excellence and minimal presence. The crystal clear wedge shaped panel allows architectural details to shine through while providing excellent light distribution and exit visibility. Long life, energyefficient LED lamps reduce energy costs and eliminate routine lamp maintenance. EXIT SIGNS > Architectural SURE-LITES® CEILING MOUNT RECESSED C E I L I N G M O U N T S U R FA C E WA L L M O U N T R E C E S S E D WA L L M O U N T S U R FA C E ES SERIES O R D E R I N G I N F O R M AT I O N - C O M P L E T E U N I T S R E C E S S E D / S U R FA C E S A M P L E N U M B E R : E S 7 17 0 W H R DAC Edge-Lit AC Only S e l f - Powe re d R e c e s s e d a n d S u r fa c e EXIT LIGHTING > Dual-voltage Input, 120/277 VAC 60Hz > 18 gauge steel housing with conduit knockouts > Extruded trim plate in Brushed or Polished Aluminum, Polished Brass, White, Black and Bronze > Injection molded highimpact acrylic panel > Clear, mirror, or white background > LED Lamping: Super-bright, long life LEDs provide uniform illumination > Sealed nickel cadmium, maintenance free, long life battery (Self Powered only) > Full Recharge Time, 24 hrs. (max.) > Recessed housing available for ceiling or wall mounting > Convenient 1/2" knockouts provided in top and end of surface mounted housing > Self-powered Exits feature solid-state voltage charger, solid-state switching, brownout circuit, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes ES Mounting Blank=Recessed S=Surface Unit Family ES=Edgelit Exit Series Series 6=LED Lamps, AC Only 7=LED Lamps, Self-Powered Face Options 1=Single Face 2=Double Face COOPER LIGHTING Letter/ Background Color R=Red/Clear (Single Face Only) RM=Red/Mirror RW=Red/White G=Green/Clear (Single Face Only) GM=Green/Mirror Battery Blank=AC Unit 70=Nickel Cadmium (Self-powered Only) Chevron Direction Blank=No Chevrons AL=Chevron Left AR=Chevron Right DA=Double Chevrons ARL=Chevron Right/Left (Double Face Only) Mounting Options C=Ceiling E=End (Surface Only) W=Wall P=Pendant (Surface Only) Voltage Blank=Dual-voltage, 120/277V O R D E R I N G I N F O R M AT I O N - R E C E S S E D H O U S I N G SAMPLE NUMBER: ESH71 Family ESH=Housing (Recessed Only) Series 6= AC Only 7=Self-Powered Face Options 1=Single Face (Self-powered Only) 2=Double Face (Self-powered Only) O R D E R I N G I N F O R M AT I O N - R E C E S S E D T R I M S A M P L E N U M B E R : E ST 7 1 W H R DAC Family EST=Trim and Panel (Recessed Only) Series 6=LED Lamps, AC Only 7=LED Lamps, Self-Powered Face Options 1=Single Face 2=Double Face Trim Finish Blank=Brushed Aluminum BL=Black PS=Polished Brass BZ=Bronze PA=Polished Aluminum WH=White Letter/ Background Color R=Red/Clear (Single Face Only) RM=Red/Mirror RW=Red/White G=Green GM=Green/Mirror GW=Green/White Voltage Chevron Blank=Dual Direction Voltage, Blank=No 120/277V Chevrons AL=Chevron Left AR=Chevron Right DA=Double Chevrons ARL=Chevron Right/Left (Double Face Only) Mounting Options C=Ceiling W=Wall Energy Data Input Power: LED Exits, Red Letters, AC Only LED Exits, Red Letters, Self-Powered LED Exits, Green Letters, AC Only LED Exits, Green Letters, Self-Powered 40 Trim Finish Blank=Brushed Aluminum BL=Black PS=Polished Brass BZ=Bronze PA=Polished Aluminum WH=White Input Current (Max.): Power Factor: 120V 277V 120V LED Exits 277V 120V 277V 120V T.H.D.: 277V 6.7W 7.0W 1.6W 2.0W 6.7W 7.0W 1.6W 2.1W .06 .06 .02 .02 .03 .03 .01 .01 .8 .8 .6 .7 .8 .8 .6 .7 20% 20% 55% 45% 20% 20% 82% 68% DESCRIPTION DIMENSIONS Architectural The CX Surface Mounted Die Cast Aluminum Exit combines the strength and durability of die casting with the bright even illumination of LED lamp sources. Unlike competitive units that have a pronounced dot effect from protruding diodes, the CX LED offers unequalled uniform illumination and brightness. The CX Self-Powered LED comes standard with the Watchguard EMS self-diagnostic system insuring fixture reliability and reducing maintenance costs. EXIT SIGNS > SURE-LITES® CX SERIES Die Cast AC Only S e l f - Powe re d EXIT LIGHTING Self-Diagnostics > Dual-voltage Input 120/277 VAC, 60 Hz, isolation transformer The self-diagnostic unit will automatically perform the tests required by the NFPA 101 Life Safety Code. The system indicates the status of the unit at all times using an LED indicator that is located near the test switch. > Die cast aluminum housing > Die cast canopy included > LED Lamping > Watchguard EMS Self-Diagnostic System (CX7 Only) O R D E R I N G I N F O R M AT I O N > Exit can be universally mounted: ceiling, wall or end SAMPLE NUMBER: CX7170RSD CX Family CX=Die Cast Aluminum Exit Series 6=AC Only, LED 7=Self-Powered, LED Battery Letter Colors Blank=No R=Red Battery (CX6) G=Green 70=Nickel Cadmium Battery (CX7) Face Options 1=Single 2=Double SD=SelfHousing Diagnostic Finishes *(CX7 only) Blank= Brushed Aluminum Face with Black Housing W=White B=Black Options 2C=Two Circuit Operation, FTBR (CX6 Only) Accessories (Order Separately) CAX18PKBK=18" Pendant Kit, Black CAX18PKWH=18" Pendant Kit, White CAX18PKHTBK=18” Hang-True Pendant Kit, Black CAX18PKHTWH=18” Hang-True Pendant Kit, White VS1=Polycarbonate Vandal Shield (Wall Mount Only) VS1WP=Weather Resistant Polycarbonate Vandal Shield (Wall Mount Only) WG10=Wire Guard (Wall Mount Only) WGS11=Wire Guard (Ceiling or End Mount Only) > Universal pattern knockouts on rear of single face housing for direct mounting to junction box > NFPA 101 compliant knockout chevrons allow quick conversion to directional signs > Self-powered Exits feature line-latching, solid-state voltage limited charger, low-voltage disconnect, brownout circuit, over-load/short-circuit protection, test switch/ power indicator light E n e rgy Da t a — S e l f - Powe re d E x i t s Sealed Nickel Cadmium Battery Input Power: Input Current (Max.): LED Exits -Red Letters LED Exits -Green Letters 120V 277V 2.8W 3.9W 2.9W 3.6W 120V 277V LED Exits .03A .08A .02A .04A Power Factor: T.H.D.: 120V 277V 120V 277V > .81 > .41 > .77 > .43 < 32% < 46% < 48% < 49% Energy Data — AC Only Exits Input Power: LED Exits -Red Letters LED Exits -Green Letters 120V 277V 2.4W 3.2W 2.5W 3.0W Input Current (Max.): 120V 277V LED Exits .03A .08A .02A .03A Power Factor: T.H.D.: 120V 277V 120V > .78 > .33 > .73 > .35 < 33% < 48% < 50% < 52% 277V > Damp Location Listed (AC Only) > UL 924 Listed, CSA Certified, Life Safety NFPA 101, NEC/OSHA, Energy Star Listed, AC Only-UL FTBR when specified with the “2C” option, most state and local codes, suitable for floor proximity installation. COOPER LIGHTING 41 DESCRIPTION DIMENSIONS The Sure-Lites Pinnacle Family of Surface Mounted Die Cast Aluminum Exits combine strength, durability and aesthetics. The architecturally compatible finishes will add a new dimension to any design. EXIT SIGNS > Architectural SURE-LITES® CAX SERIES Die Cast AC Only LED Lamping EXIT LIGHTING O R D E R I N G I N F O R M AT I O N - L E D L A M P E X I T S S A M P L E N U M B E R : C A X 6 10 0 6 5 R B > 120 VAC or 277 VAC Input wattage > Die cast aluminum housing with hinged face plate and die cast canopy for ceiling or end mounting > Universal: ceiling, wall, or end mounting > Screw-In LED Lamps: two 1W long life T6 1/2 intermediate base lamps > Universal pattern knockouts on rear of single face housing for direct mounting to junction box > NFPA 101 compliant knockout chevrons allow quick conversion to directional signs > Damp Location Listed (except exits with “2C” Option) > UL 924 Listed, Life Safety NFPA 101, CSA certified, NEC/OSHA, UL FTBR Listed (consult your Cooper Lighting Representative for applicable fixture types), most state and local codes CAX Family CAX=Die Cast Aluminum Exit Surface Mount Factory Options 00=No Options 65=Tamperproof Screws 85=Vandal Shield Series 6=AC Only,LED Letter Colors R=Red G=Green Face Options 1=Single 2=Double Housing Finishes Blank=Brushed Aluminum Face with Black Housing W=White B=Black BZ=Bronze Voltage Blank=120/277V 47=120/347V Battery 00=No Battery Factory Options 2C= Two Circuit Operation Accessories (Order Separately) Screwdrivers 059012SP=Tamperproof Screwdriver Bit VRSD=Vandal Resistant Screwdriver WG10=Surface, Mount Wire Guard WGS11=Ceiling, End Mount Wire Guard VS1=polycarbonate vandal shield Pendant Kits CAX18PK=Pendant Kit, white CAX18PKHT=”Hang-true” Pendant Kit, white O R D E R I N G I N F O R M AT I O N - S C R E W - I N L E D E X I T S S A M P L E N U M B E R : C A X 1 L E DAC R CAX Family CAX=Die Cast Aluminum Exit Surface Mount Face Options 1=Single 2=Double Factory Options 65=Tamperproof Screws 85=Vandal Shield 95=AC Only Fire Alarm Interface Lamp Type LED=LED Lite Stix™ Screw-in LED Lamps Emergency Operation AC=AC Only Letter Color R=Red Housing Finishes Blank=Brushed Aluminum Face with Black Housing W=White B=Black BZ=Bronze Voltage Blank=120V 77=277V Accessories (Order Separately) DC Socket Kit PDC6=Two 6V, 3.6W DC lamps PDC12=Two 12V, 3.6W DC lamps Emergency Power Pack CAX3PP=Black CAX3PPW=White CAX3PPBZ=Bronze 277V Conversion Kit AD277CAX=Black AD277CAXW=White AD277CAXBZ=Bronze Vandal Resistant Screwdrivers 059012SP=Tamperproof Screwdriver Bit VRSD=Vandal Resistant Screwdriver WG10=Surface, Mount Wire Guard WGS11=Ceiling, End Mount Wire Guard VS1=Polycarbonate Vandal Shield Energy Data Red Letters Single Face Red Letters Double Face Green Letters Single Face Green Letters Double Face Red Letters 42 COOPER LIGHTING Input Power: Input Current(Max.): 120V 277V 347V 120V 277V 347V Standard Power - LED Exits 5.6W 5.7W 6.0W .07A .03A .02A 7.3W 7.5W 8.3W .07A .03A .03A 6.7W 6.8W 6.8W .07A .03A .02A 9.5W 9.7W 9.9W .09A .04A .03A LED Lite-Stix™ Screw-In Lamps 2.0W 4.3W .09A .03A Power Factor: 120V 277V T.H.D.: 120V 277V >.71 >.83 >.79 >.90 >.71 >.83 >.79 >.90 <36% <33% <30% <26% <36% <34% <31% <27% >.19 >.58 <19% <22% DIMENSIONS DESCRIPTION Architectural The Sure-Lites Pinnacle Family of Surface Mounted Die cast Aluminum Exits combine a strength, durability and aesthetics. The architecturally compatible finishes will add a new dimension to any design. EXIT SIGNS > SURE-LITES® CAX SERIES Die Cast AC Only Incandescent, Compact Fluorescent Lamping EXIT LIGHTING O R D E R I N G I N F O R M AT I O N - I N C A N D E S C E N T, F L U O R E S C E N T L A M P E X I T S S A M P L E N U M B E R : C A X 4 10 0 6 5 R B CAX Family CAX=Die Cast Aluminum Exit Series 2=AC Only, Incandescent 4=AC Only, Fluorescent Face Options 1=Single 2=Double Battery 00=No Battery Factory Options 00=No Options 65=Tamperproof Screws 85=Vandal Shield 95=AC Only Fire Alarm2 Interface Letter Colors R=Red G=Green RWO=Red on White1 GWO=Green on White1 WRO=White on Red1 WGO=White on Green1 O=Open Face1 Housing Finishes Blank=Brushed Aluminum Face with Black Housing W=White B=Black BZ=Bronze > 120 VAC or 277 VAC input voltage Factory Options 2C= Two Circuit Operation Accessories (Order Separately) DC Socket Kit (Incandescent only) PDC6=Two 6V, 3.6W DC lamps PDC12=Two 12V, 3.6W DC lamps > Universal: ceiling, wall, or end mounting Emergency Power Pack (Incandescent Only) CAX3PP=Black CAX3PPW=White CAX3PPBZ=Bronze Voltage Blank=120V 77=277V > Die cast aluminum housing with hinged face plate and die-cast canopy for ceiling or end mounting > AC incandescent: two 20W T6 1/2 intermediate base lamps 277V Conversion Kit AD277CAX=Black AD277CAXW=White AD277CAXBZ=Bronze > AC fluorescent: two 5W F5TT compact fluorescent lamps Screwdrivers 0590-12SP=Tamperproof Screwdriver Bit VRSD=Vandal Resistant Screwdriver Wire Guard WG1=Surface, Wire Guard WGS11=Ceiling, End Wire Guard VS1=Polycarbonate Vandal Shield Pendant Kits CAX18PK=Pendant Kit, white CAX18PKHT=”Hang-true” Pendant Kit, white > Universal pattern knockouts on rear of single face housing for direct mounting to junction box > NFPA 101 compliant knockout chevrons allow quick conversion to directional signs > Stencil and open face signs available > Downlight diffuser Energy Data Input Power: 120V 277V Incandescent Exits 4.0W 4.2W Fluorescent Exits - 5W Lamps Fluorescent Exits - 7W Lamps 14W 15W 21W 23W Input Current (Max.): 120V 277V Incandescent Exits .33A .16A Fluorescent Exits .29A .32A .25A .30A > Damp Location Listed Power Factor: 120V 277V T.H.D.: 120V 277V - - - - >.40 >.50 >.24 >.27 <14% <16% <11% <12% > UL 924 Listed, Life Safety NFPA 101, CSA certified, NEC/OSHA, UL FTBR Listed (consult your Cooper Lighting Representative for applicable fixture types), most state and local codes Notes: AC compact fluorescent CAX Series Exits cannot be converted to self-powered emergency. 1RWO, GWO, WRO, and WGO are open face styles with “EXIT” legend. Use “O” option for ordering special wording-lenses ordered separately (consult Cooper Lighting Representative). 2AC Only Fire Alarm Interface Option available on incandescent lamp exits only. COOPER LIGHTING 43 DESCRIPTION DIMENSIONS The Sure-Lites Pinnacle Family of Surface Mounted Die cast Aluminum Exits combine strength, durability and aesthetics. The architecturally compatible finishes will add a new dimension to any design. EXIT SIGNS > Architectural SURE-LITES® CAX SERIES O R D E R I N G I N F O R M AT I O N - L E D L A M P E X I T S Die Cast S e l f - Powe re d LED Lamping EXIT LIGHTING > Dual-voltage input 120/277VAC, 60Hz > Die cast Aluminum housing with hinged faceplate and die cast canopy for ceiling or end mounting > Universal: ceiling, wall, or end mounting > Screw-in LED lamps: two 1W long life T 6 1/2 intermediate base lamps > Lead Calcium or Premium Nickel Cadmium battery > Universal pattern knockouts on rear of single face housing for direct mounting to junction box SAMPLE NUMBER: CAX717020R CAX Family CAX=Die Cast Aluminum Exit Surface Mount Factory Options 00=No Options 20=DC Flasher 30=DC Flasher/ Buzzer 65=Tamperproof Screws 85=Vandal Shield 90=DC Only Fire Alarm Interface Series 7=Self-Powered LED Face Options 1=Single 2=Double > UL 924 Listed, Life Safety NFPA 101, CSA certified, NEC/OSHA, most state and local codes 44 COOPER LIGHTING Factory Options SD=Self Diagnostics Letter Colors R=Red G=Green Battery 70=Nickel Cadmium Accessories (Order Separately) Screwdrivers 0590-12SP=Tamperproof Screwdriver Bit VRSD=Vandal Resistant Screwdriver VS1=polycarbonate vandal shield Pendant Kits CAX18PK=Pendant Kit, white CAX18PKHT=”Hang-true” Pendant Kit, white WG10=Surface WGS11=Ceiling, end O R D E R I N G I N F O R M AT I O N - S C R E W - I N L E D L A M P S SAMPLE NUMBER: CAX1LEDSPR Family CAX=Die Cast Aluminum Exit Surface Mount Face Options 1=Single 2=Double Battery Blank=Lead Calcium 70=Nickel Cadmium Factory Options Blank=None 20=DC Flasher 30=DC Flasher/ Buzzer 65=Tamperproof Screws 85=Vandal Shield 90=DC Fire Alarm Interface Lamp Type LED=LED Lite Stix™ Screw-in LED Lamps > NFPA 101 compliant knockout chevrons allow quick conversion to directional signs > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light Housing Finishes Blank=Brushed Aluminum Face with Black Housing W=White B=Black BZ=Bronze Emergency Operation SP=Self-Powered Factory Options SD= Self-Diagnostics Letter Color R=Red Housing Finishes Blank=Brushed Aluminum Face with Black Housing W=White B=Black BZ=Bronze Voltage Blank=120V/277V 47=120/347V Accessories (Order Separately) 059012SP=Tamperproof Screwdriver Bit VRSD=Vandal Resistant Screwdriver VS1=polycarbonate vandal shield Pendant Kits CAX18PK=Pendant Kit, white CAX18PKHT=”Hang-true” Pendant Kit, white WG10=Surface WGS11=Ceiling, end Wa tt a g e R a t i n g s Lead Calcium Battery=10.8W for 1 1/2 hrs., 7.2W for 2 hrs. Nickel Cadmium Battery=15.0W for 1 1/2 hrs. Energy Data Standard Power - Sealed Nickel Cadmium Battery - LED Exits Input Power: Input Current (Max.): Power Factor: T.H.D.: 120V 277V 347V 120V 277V 347V 120V 277V 120V 277V Red Letters Single Face 7.4W 7.5W 7.6W .08A .04A .03A >.72 >.72 <34% <34% Red Letters Double Face 9.3W 9.5W 9.6W .09A .04A .03A >.84 >.84 <31% <32% Green Letters Single Face 8.5W 8.7W 8.4W .09A .04A .03A >.79 >.79 <30% <31% Green Letters Double Face 11.4W 11.7W 11.2W .11A .05A .04A >.90 >.90 <26% <26% Standard Power with Self Diagnostics Option (Fully Discharged Battery) - LED Exits Red Letters Single Face 8.4W 8.5W 8.6W .08A .04A .03A >.82 >.82 <31% <31% Red Letters Double Face 9.8W 9.5W 9.7W .09A .04A .03A >.86 >.84 <30% <30% Green Letters Single Face 9.1W 9.0W 9.2W .09A .04A .03A >.86 >.85 <27% <27% Green Letters Double Face 11.2W 10.5W 10.5W .10A .05A .03A >.90 >.88 <25% <26% Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by approximately 1.5 Watts Self Diagnostic Option with Low Power Option (Operating in Low Power Mode) (Fully Discharged Battery) - LED Exits Red Letters Single Face 6.5W 6.7W .07A .03A >.75 >.72 <37% <37% Red Letters Double Face 7.8W 8.1W .08A .04A >.80 >.80 <33% <33% Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by approximately 4 Watts Charge Mode, Fully Discharged Battery): Sealed Lead Calcium Battery Screw-in LED Lamps Red Letters 16.6W 17.5W .15A .07A >.90 >.91 <28% <28% Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by approximately 10 Watts in the standby operating mode Sealed Nickel Cadmium Battery: Screw-in LED Lamps Red Letters 8.4W 8.3W .08A .03A >.92 >.92 <35% <34% DESCRIPTION DIMENSIONS Architectural The Sure-Lites Pinnacle Family of Surface Mounted Die Cast Aluminum Exits combine strength, durability and aesthetics. The architecturally compatible finishes will add a new dimension to any design. EXIT SIGNS > SURE-LITES® CAX SERIES Die Cast S e l f - Powe re d O R D E R I N G I N F O R M AT I O N - I N C A N D E S C E N T, F L U O R E S C E N T E X I T S S A M P L E N U M B E R : C A X 3 10 0 8 5 R Incandescent, Compact Fluorescent Lamping CAX Family CAX=Die Cast Aluminum Exit Surface Mount Factory Options 00=No Options 20=DC Flasher1 30=DC Flasher/ Buzzer1 65=Tamperproof Screws 85=Vandal Shield 90=DC Only Fire Alarm Interface1 Series 3=Self-Powered, Incandescent 5=Self-Powered, Fluorescent Face Options 1=Single 2=Double Housing Finishes Blank=Brushed Aluminum Face with Black Housing W=White B=Black BZ=Bronze Voltage Blank=120V/277V Accessories (Order Separately) Screwdrivers 059012SP=Tamperproof Screwdriver Bit VRSD=Vandal Resistant Screwdriver Wire Guard WG1=Surface, Wire Guard WGS11=Ceiling, End Wire Guard Letter Colors R=Red G=Green RWO=Red on White2 GWO=Green on White2 WRO=White on Red2 WGO=White on Green2 O=Open Face2 Battery 00=Lead Calcium 70=Nickel Cadmium Factory Options SD=Self-Diagnostic (Incandescent Only) VS1=Polycarbonate Vandal Shield Pendant Kits CAX18PK=Pendant Kit, white CAX18PKHT=”Hang-true” Pendant Kit, white EXIT LIGHTING > Dual-voltage input 120/277VAC, 60Hz > Die cast aluminum housing with hinged faceplate and die-cast canopy for ceiling or end mounting > Universal: ceiling, wall, or end mounting > AC incandescent: two 20W T6 1/2 intermediate base lamps > AC fluorescent: two 5W F5TT compact fluorescent lamps > Lead Calcium or Premium Nickel Cadmium battery Wa tt a g e R a t i n g s Lead Calcium Battery=10.8W for 1 1/2 hrs., 7.2W for 2 hrs. Nickel Cadmium Battery=15.0W for 1 1/2 hrs. > Universal pattern knockouts on rear of single face housing for direct mounting to junction box Energy Data Charge Mode (Fully Discharged Battery): Sealed Lead Calcium Battery Input Power: Input Current (Max.): Power Factor: 120V 277V 120V 277V 120V 277V Incandescent Exits-20W Lamps 53W Fluorescent Exits-5W Lamps 29W 51W 30W .45A .40A .19A .16A >.99 >.61 >.98 >.66 T.H.D.: 120V 277V <9% <12% <10% <11% Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 12 Watts in the standby operating mode Sealed Nickel Cadmium Battery Incandescent Exits-20W Lamps 45W 43W .38A .16A >.99 >.99 <7% <7% Fluorescent Exits - 5W Lamps 20W 21W .36A .15A >.48 >.52 <15% <14% > NFPA 101 compliant knockout chevrons allow quick conversion to directional signs > Stencil and open face signs available > Downlight diffuser > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, CSA Certified, NEC/OSHA, UL FTBR Listed, most state and local codes 1DC Flasher, DC Flasher/Buzzer and DC Fire Alarm Interface options available with Incandescent exits only. 2RWO, GWO, WRO, and WGO are open face styles with “Exit” legend. Use “O” option for ordering special wording-lenses ordered separately (consult Cooper Lighting Representative). COOPER LIGHTING 45 DIMENSIONS DESCRIPTION EXIT SIGNS > Architectural SURE-LITES® TPX SERIES Die Cast AC Only R E M OT E POWERED A C O N LY The TPX Thin Profile Exit Series combines the strength of die cast aluminum, the profile of recessed design and the superior aesthetics of LED technology. The TPX Series faceplate assembly is only 3/4" thick, yielding a sign with minimal off-wall protrusion without requiring the large wall opening of a fully recessed exit. The TPX Series also includes a Remote Powered Exit which can be powered from a TPX Series AC Only or SelfPowered Exit. Thin Profile EXIT LIGHTING O R D E R I N G I N F O R M AT I O N - A C O N LY E X I T S > Dual-voltage input 120/277VAC, 60Hz > Die cast aluminum faceplate > Overall exposed exit thickness is only 3/4" > LED lamping S A M P L E N U M B E R : T P X 6 10 0 0 0 R B TPX Family TPX=Thin Profile Exit Series 6=AC Only, LED > 20 gauge steel recessed housing fits in 2x4 construction Face Options 1=Single > 18 gauge steel mounting plate with universal mounting pattern Battery 00=AC Only, 120/277 VAC > Adjustable hanger bars > Centerpin Torx tamper resistant screws on sides of faceplate – no visible mounting hardware on front face > NFPA compliant knockout chevrons > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, UL FTBR Listed (with “2C” option), UL Listed as suitable for floor proximity installation, most state and local codes Factory Options 00=No Options 95=AC Only Fire Alarm Interface Letter Colors R=Red G=Green Faceplate Finishes Blank=Brushed Aluminum Face with Black Trim W=White B=Black BZ=Bronze Accessories (Order Separately) TPX61VS=Polycarbonate Vandal Shield 0590A639SP=Tamper Resistant Screwdriver Bit Factory Options 2C= Two Circuit Operation O R D E R I N G I N F O R M AT I O N - R E M O T E P O W E R E D E X I T S (Satellite, must be powered from another unit.) S A M P L E N U M B E R : T P X 8 10 0 0 0 R Family TPX=Thin Profile Exit Factory Options 00=No Options Series 8=Remote, LED Letter Colors R=Red G=Green Face Options 1=Single Battery 00=Remote Powered Faceplate Finishes Blank=Brushed Aluminum Face with Black Trim W=White B=Black BZ=Bronze Accessories (Order Separately) TPX61VS= Polycarbonate Vandal Shield 0590A639SP= Tamper Resistant Screwdriver Bit Energy Data Red Letters Single Face 5.6W Red Letters Single Face with Remote Green Letters Single Face 6.7W Green Letters Single Face with Remote Red Letters Single Face Green Letters Single Face 46 COOPER LIGHTING Standard Power - LED Exits Input Power: Input Current (Max.): 120V 277V 120V 277V 5.7W .07A .03A >.71 7.3W 7.3W .07A .03A 6.8W .07A .03A >.79 9.5W 9.7W .09A .04A Remote Powered - LED Exits Approximately 2.0 watts additional Approximately 2.5 watts additional Power Factor: 120V 277V >.71 <36% >.83 >.83 >.79 <30% >.90 >.90 T.H.D.: 120V 277V <36% <33% <34% <31% <26% <27% DIMENSIONS DESCRIPTION The TPX Series also includes a Remote Powered Exit which can be powered from a TPX Series AC Only or Self-Powered Exit. Architectural The TPX Thin Profile Exit Series combines the strength of die cast aluminum, the profile of recessed design and the superior aesthetics of LED technology. The TPX Series faceplate assembly is only 3/4" thick, yielding a sign with minimal off-wall protrusion without requiring the large wall opening of a fully recessed exit. EXIT SIGNS > SURE-LITES® TPX SERIES Die Cast S e l f - Powe re d Thin Profile EXIT LIGHTING > Dual-voltage input 120/277VAC, 60Hz O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: TPX717020RB > Die cast aluminum faceplate TPX Family TPX=Thin Profile Exit Factory Options 00=No Options 20=Flasher 30=Flasher/Buzzer 90=DC Fire Alarm Interface Series 7=Self-Powered Face Options 1=Single Letter Colors R=Red G=Green Faceplate Finishes Blank=Brushed Aluminum Face with Black Trim W=White B=Black BZ=Bronze Accessories (Order Separately) TPX71VS=Polycarbonate Vandal Shield 0590A639SP=Tamper Resistant Screwdriver Bit > LED Lamping > Premium Nickel Cadmium battery > 20 gauge steel recessed housing fits in 2x4 construction Factory Options SD= Self-Diagnostics Battery 70=Nickel Cadmium Battery > Overall exposed exit thickness is only 3/4" > 18 gauge steel mounting plate with universal mounting pattern > Adjustable hanger bars Energy Data Standard Power - Sealed Nickel Cadmium Battery - LED Exits Red Letters Single Face Red Letters Single Face with Remote Green Letters Single Face Green Letters Single Face with Remote Input Power; 120V 277V 7.4W 7.5W 9.3W 9.5W 8.5W 8.7W 11.4W 11.7W Input Current (Max.): 120V 277V .08A .04A .09A .04A .09A .04A .11A .05A Power 120V >.72 >.84 >.79 >.90 Factor: 277V >.72 >.84 >.79 >.90 T.H.D.: 120V 277V <34% <34% <31% <32% <30% <31% <26% <26% Standard Power with Self-Diagnostics Option ( Fully Discharged Battery) - LED Exits Red Letters Single Face Red Letters Single Face with Remote Green Letters Single Face Green Letters Single Face with Remote 8.4W 9.8W 9.1W 11.2W 8.5W 9.5W 9.0W 10.5W .08A .09A .09A .10A .04A >.82 >.82 <31% .04A >.86 >.84 <30% .04A >.86 >.85 <27% .05A >.90 >.88 <25% Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced mately 1.5 Watts in the standby operating mode <31% <30% <27% <26% by approxi- > Centerpin Torx tamper resistant screws on sides of faceplate > NFPA compliant knockout chevrons > Line-latching, Solid-State voltage limited charger, Solid-State switching, lowvoltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, UL FTBR Listed (with “2C” option), UL Listed as suitable for floor proximity installation, most state and local codes COOPER LIGHTING 47 DESCRIPTION DIMENSIONS The Sure-Lites Pinnacle Family of Die Cast Aluminum Exits combine strength, durability and aesthetics. The fully recessed CAR Series offers a very clean unobtrusive look. The die cast faceplate is offered in four finishes. EXIT SIGNS > Architectural SURE-LITES® CAR SERIES Die Cast AC Only Recessed EXIT LIGHTING O R D E R I N G I N F O R M AT I O N > Dual Voltage Input 120/277 VAC, 60 Hz > Die cast aluminum face plate > LED, Compact Fluorescent, or Incandescent lamping > AC incandescent: two 20W T6 1/2 intermediate base lamps > AC fluorescent: two 5W F5TT compact fluorescent lamps > NFPA 101 compliant knockout chevrons allow quick conversion to directional signs S A M P L E N U M B E R : C A R 2 10 0 0 0 G B CAR Family CAR=Die Cast Aluminum Exit Recessed Mount Series 2=AC Only, Incandescent 4=AC Only, Fluorescent 6=AC Only, LED (120/277) Face Options 1=Single Battery 00=No Battery > Rough-in back box for recessed mounting Factory Options 00=No Options 65=Tamperproof Screws 85=Vandal Shield 95=AC Only Fire Alarm Interface2 Letter Colors R=Red G=Green RWO=Red on White1 (except LED) GWO=Green on White1 (except LED) WRO=White on Red1 (except LED) WGO =White on Green1 (except LED) O=Open Face1 (except LED) Faceplate Finishes Blank=Brushed Aluminum W=White B=Black BZ=Bronze Factory Options 2C= Two Circuit Operation Voltage Blank=120V 77=277V (Incandescent and Fluorescent only) Accessories (Order Separately) 059012SP=Tamperproof Screwdriver Bit VRSD=Vandal Resistant Screwdriver > Hanger bars supplied standard for mounting > Faceplate secures to rough-in box with torsion springs > Stencil and open face signs available Energy Data Incandescent Exits - 20W Lamps Fluorescent Exits - 5W Lamps > Damp Location Listed LED Exits - Single Face Input Power: Input Current (Max.): 120V 277V 120V 277V Incandescent Exits 40W 42W .33A .16A Fluorescent Exits 14W 21W .29A .32A LED Exits 6.7W 6.8W .07A .03A Power Factor: 120V 277V T.H.D.: 120V 277V - - - - >.40 >.24 <14% <11% >.79 >.79 <30% <31% > UL 924 Listed, UL FTBR Listed (consult Cooper Lighting Representative for applicable fixture types), Life Safety NFPA 101, NEC/OSHA, most state and local codes > Suitable for floor proximity installation Notes: AC compact fluorescent CAR Series Exits cannot be converted to self-powered emergency. 1Available 48 COOPER LIGHTING only for incandescent and fluorescent versions. RWO, GWO, WRO, and WGO are open face styles with “EXIT” legend. Use “O” option for ordering special wording-lenses ordered separately (consult Cooper Lighting Representative). 2AC Only Fire Alarm Interface Option available on incandescent exits only. DIMENSIONS DESCRIPTION Architectural The Sure-Lites Pinnacle Family of Die Cast Aluminum Exits combine strength, durability and aesthetics. The fully recessed CAR Series offers a very clean unobtrusive look. The die cast faceplate is offered in four finishes. EXIT SIGNS > SURE-LITES® CAR SERIES Die Cast Self-powered Recessed EXIT LIGHTING O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : C A R 3 10 0 2 0 R W > Dual-voltage input 120/277VAC, 60Hz CAR Family CAR=Die Cast Aluminum Exit Recessed Mount Series 3=Self-Powered, Incandescent 5=Self-Powered, Fluorescent 7=Self-Powered, LED Face Options 1=Single Battery 00=Lead Calcium Battery (CAR3 & CAR5 Only) 70=Nickel Cadmium Battery Factory Options 00=No Options 20=DC Flasher2 30=DC Flasher/ Buzzer2 65=Tamperproof Screws 85=Vandal Shield 90=DC Only Fire Alarm Interface2 Faceplate Finishes Blank=Brushed Aluminum W=White B=Black BZ=Bronze Voltage Blank=120/277V Factory Options SD=Self Diagnostics (Incandescent & LED Only) Accessories (Order Separately) 059012SP=Tamperproof Screwdriver Bit VRSD=Vandal Resistant Screwdriver Letter Colors R=Red G=Green RWO=Red on White1 (except LED) GWO=Green on White1 (except LED) WRO=White on Red1 (except LED) WGO=White on Green1 (except LED) O=Open Face1 (except LED) > Die cast aluminum face plate > LED, Compact Fluorescent, or Incandescent lamping > AC Incandescent: two 20W T6 1/2 intermediate base lamps; DC Incandescent: two 6V, 3.6W lamps > AC and DC Fluorescent: Two 5W F5TT compact fluorescent lamps > Lead Calcium or Premium Nickel Cadmium battery > NFPA 101 compliant knockout chevrons allow quick conversion to directional signs > Rough-in back box for recessed mounting Wa tt a g e R a t i n g s Lead Calcium Battery=10.8W for 1 1/2 hrs. Nickel Cadmium Battery=15.0W for 1 1/2 hrs. Energy Data (Charge Mode, Fully Discharged Battery): Sealed Lead Calcium Battery Input Power: Input Current (Max.): Power Factor: T.H.D.: 120V 277V 120V 277V 120V 277V 120V 277V Incandescent Exits - 20W lamps 53W 51W .45A .19A >.99 >.98 <9% <10% Fluorescent Exits-5W Lamps 29W 30W .40A .16A >.61 >.66 <12% <11% LED Exits 8.0W 8.0W .09A .04A >.75 >.75 <34% <34% Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 12 Watts in the standby operating mode Sealed Nickel Cadmium Battery Incandescent Exits - 20W Lamps 45W 43W .38A .16A >.99 >.99 <7% <7% Fluorescent Exits - 5W Lamps 20W 21W .36A .15A >.48 >.52 <15% <14% > Faceplate secure to rough in box with torsion springs > Stencil and open face signs available > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, UL FTBR Listed, most state and local codes > Suitable for floor proximity installation 1Available only for incandescent and fluorescent versions. RWO, GWO, WRO, and WGO are open face styles with “EXIT” legend. Use “O” option for ordering special wording-lenses ordered separately (consult Cooper Lighting Representative). Flasher, DC Flasher/Buzzer, DC Only Fire Alarm Interface Options available on incandescent exits only. 2DC COOPER LIGHTING 49 DESCRIPTION EXIT SIGNS > Commercial SURE-LITES® LPX SERIES Po l yc a r b o n a te AC Only DIMENSIONS The LPX Series LED Exit is an economical, yet attractive, alternative to metal exits. Its contemporary round corner styling, designer white finish, and consistent family appearance enables it to blend with any decor. The tough injection molded polycarbonate materials resist discoloration. The canopy and chevron directional indicators, are of snap-fit construction to facilitate installation. The under 5-minute installation time makes it the fastest installed exit on the market today. 4 1/2" [114mm] 6" [152mm] 3/4" [19mm] 7 1/2" [190mm] 2 1/8" [54mm] 13" [330mm] S e l f - Powe re d EXIT LIGHTING > Dual-voltage Input 120/277 VAC, 60Hz, isolation transformer > Injection molded polycarbonate housing > LED lamping > Premium Nickel Cadmium battery (Self Powered) > Fully charged in 24 hours (Self-Powered Exits) > Snap-fit canopy included > Snap-out or snap-in chevron directional indicators > Knockout provided on housing for surface attachment > Universal exits can be field configured as single face or double face (ceiling, wall, or end mounting) > Self-powered Exit features line-latching, solid-state voltage limited charger, solid-state switching, brownout circuit, low-voltage disconnect, overload/short-circuit protection, test switch/power indicator light > UL Damp Location Listed (AC Only & Self-Diagnostic versions) > Optional 2C (Two circuit, FTBR) available in 120/277 VAC in standard and emergency operation (AC Only Exits) > UL 924 Listed, Life Safety NFPA 101, CSA Certified, NEC/OSHA, most state and local codes, suitable for floor proximity installation > Patent No. 5,735,498 and 5,678,336 50 COOPER LIGHTING O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: LPX70RWH LPX Family LPX=Polycarbonate Exit Letter Colors R=Red G=Green (White Only) DG=Premium Deep Green Series 6=AC only with LED 7=Self-Powered with LED Housing Finishes WH=White BK=Black Face Options 0=Universal Options 2C=Two Circuit Option (FTBR) (LPX6 Only) SD=Self Diagnostics (Red and Deep Green, White Housing Only. LPX7 Only) Battery Blank=No Battery (LPX6) Blank=Nickel Cadmium Battery (LPX7) Accessories (Order Separately) CCX18PKWH=18” Pendant Kit, White CCX18PKHTWH=18” Hang True Pendant Kit, White CCX18PKBK=18” Pendant Kit, Black CCX18PKHTBK=18” Hang True Pendant Kit, Black WG10=Surface, Wire Guard WGS11=Ceiling, End Wire Guard VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weather Proof E n e rgy Da t a – S e l f - Powe re d E x i t s Charge Mode (Fully Discharged Battery): Sealed Nickel Cadmium Battery Input Power: Input Current (Max.): Power Factor: T.H.D.: 120V 277V 120V 277V LED Exits 120V 277V 120V LED Exits -Red Letters LED Exits Green LED Exits-Red Letters SD 2.8W 2.9W 6.0W 6.4W 1.7W 1.7W .03A .02A .09A .04A .03A .01A Premium > .81 > .58 >.63 > .77 > .56 >.64 < 32% < 46% < 42% < 45% <43% <48% Premium Deep Green Premium Deep Green SD 4.0W 3.1W > .41 >.34 > .41 >.36 < 48% < 49% <63% <67% 4.0W 3.0W .08A .08A .04A .04A 277V Energy Data – AC Only Exits Input Power: Input Current (Max.): 120V 277V 120V 277V LED Exits LED Exits -Red Letters LED Exits -Green Letters 2.4W 5.6W 2.5W 5.9W .03A .08A Premium Premium Deep Green 2.6W 2.6W .08A Power Factor: T.H.D.: 120V 277V 120V 277V .02A .04A > .78 > .55 > .73 > .53 < 33% < 48% < 43% < 45% .04A > .28 > .28 < 51% < 53% DESCRIPTION DIMENSIONS The tough injection molded polycarbonate materials resist discoloration due to age and ultraviolet radiation. The canopy and chevron directional indicators are of snap-fit construction to facilitate installation. Reliable and labor-saving push-in AC connectors are standard to further improve the installation time. The under 5-minute installation time makes it the fastest installed exit on the market today. Commercial The LPX Series LED Exit is an economical, yet attractive, alternative to metal exits. Its contemporary round corner styling, designer white finish, and consistent family appearance enables it to blend with any decor. EXIT SIGNS > SURE-LITES® LPX(H) SERIES EXITS Po l yc a r b o n a te S e l f - Powe re d H i g h Powe r (Remote Capacity) Double Heads EXIT LIGHTING > Dual Voltage Input 120/277 VAC, 60Hz, isolation transformer O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: LPX70RWHDH > Injection molded, high impact, polycarbonate housing > LED lamping Family LPX=Polycarbonate Exit LPXH=High Power* (Remote Capacity) Letter Colors R=Red DG=Premium Deep Green Housing Finishes WH=White BK=Black (Red Only) Voltage Blank=120/277 VAC Heads Blank=No Heads (LPXH Only) DH=Double Heads Series 7=Self-Powered with LED Face Options 0=Universal Options SD=Self-Diagnostics (Red Only) Battery Blank=Lead Calcium Accessories (Order Separately) CCX18PKWH=18” Pendant Kit, White CCX18PKHTWH=18” Hang True Pendant Kit, White WG10=Wall Mount (without heads) WGS11=Ceiling or End Mount (without heads) WG12=Wall Mount (with heads) WG17=Ceiling or Wall Mount (with heads) VS1=Polycarbonate Vandal Shield (without heads) VS2=Polycarbonate vandal shield (with heads) LPX1HWH=Head assembly, White (LPXH only) Energy Data Standby Mode (Fully charged Battery): Sealed Lead Calcium Battery Input Power: Input Current (Max.): Power Factor: LED Exits -Red Letters LED Exits-Red Letters SD 120V 277V 120V 277V LED Exits 4.9W 4.0W 4.7W 3.9W .07A .06A Premium .03A .02A T.H.D.: 120V 277V 120V > .59 >.57 > .64 >.58 < 45% < 44% <40% <46% Premium Deep Green 277V 3.1W 2.9W .06A .02A > .41 > .44 < 49% < 53% Charge Mode (Discharged Battery): Sealed Lead Calcium Battery Input Power consumption is increased by approximately 2.7 watts in the charge operating mode for red units and 3.4 watts for green units > Heads DC: 6V, 5.4W incandescent wedge base lamps. PAR 36 Style > Sealed Lead Calcium Battery, Maintenance Free, Long Life, Full Recharge Time, 24 hours (max.); 48 hours (max.) for LPXH units > Universal exits can be field configured as single face or double face (ceiling, wall or end mounting) > Knockout provided on housing for surface conduit attachment > Snap-fit canopy with captive mounting screws included with all exits > Line-Latching, Solid-State Voltage Limited Charger, Solid-State Switching, Brownout Circuit, Low- Voltage Disconnect, Overload/Short Circuit Protection, Test Switch/ Power Indicator Light, Push-in AC power connectors facilitate installation > Damp Location Listed Standard > UL 924, UL 924, 4 hour rated (LPXH Units), Life Safety NFPA 101, CSA Certified, NEC/OSHA, suitable for floor proximity installation Wa tt a g e R a t i n g s LPXH* with double-heads (DH) has remote capacity of 11 watts for 1 1/2 hrs. No remote capacity for 4 hrs. LPXH has Remote Capacity of 22 watts for 1 1/2 hrs. and 11 watts for 4 hrs. COOPER LIGHTING 51 DESCRIPTION EXIT SIGNS > Commercial SURE-LITES® CCX SERIES DIMENSIONS The CCX Series Contractor’s Choice Exit is an economical, attractive, alternative to metal exits. Contemporary round corner styling, designer finish, and consistent family appearance enables it to blend with any decor. The tough injection molded polycarbonate materials resist discoloration. The canopy and chevron directional indicators are of snap-fit construction to facilitate installation. Po l yc a r b o n a te AC Only EXIT LIGHTING O R D E R I N G I N F O R M AT I O N > Dual voltage input 120/277 VAC, 60 Hz > Injection molded, high impact, polycarbonate housing > Designer white textured finish standard (Black Available-Fluorescent Only) > LED, Fluorescent or Incandescent lamping > LED: long life LED lamp modules > Fluorescent: two 5W F5TT lamps > Incandescent: two 145V, 15W T6 lamps (candelabra base) SAMPLE NUMBER: CCX20RWH CCX Family CCX=Contractor’s Choice Exit Series 2=AC Only with 145V, 15W T-6 AC Incandescent Lamps 4=AC Only with 5W F5TT Compact Fluorescent Lamps 6=AC only with LED Lite Stix™ Face Options 0=Universal 1=Single Face 2=Double Face Factory Options Blank=No Options 65=Tamperproof Screws 95=AC Fire Alarm Interface (for Incandescent & LED) Letter Colors 1 R=Red G=Green RWO=Red on White1 GWO=Green on White1 WRO=White on Red1 WGO=White on Green1 O=Open Face1 Housing Finishes BK=Black (Fluorescent Only) WH=White Voltage Blank=120 VAC 7=120/277 VAC (for Incandescent & Fluorescent) 7=277 VAC (LED only) 47= 120/347 VAC (Incandescent only) Battery Blank=No Battery > Ceiling, wall or end mounting > Universal J-box mounting pattern > Push-in power connectors facilitate installation > Snap-fit canopy included > Components are snap-fit construction, reinforcing ribs add strength > Snap-out chevron directional indicators > UL FTBR Listed with 2C option (7W Lamps Only. Fluorescent Exits Only.) > Damp Location Listed Factory Options 2C=Two Circuit Operation includes 7W lamps (Fluorescent Only) C7=130V, 7W C-7 AC Incandescent Lamps (Incandescent Only) 7W=7W Compact Fluorescent Lamps (Fluorescent Only) Accessories (Order Separately) CCX18PKBK=18” Pendant Kit, Black CCX18PKWH=18” Pendant Kit, White CCX18PKHTBK=18” Hang-True Pendant Kit, Black CCX18PKHTWH=18” Hang-True Pendant Kit, White CCX277=277V Conversion Kit VRSD=Tamper Resistant Screwdriver WG10=Surface, Wire Guard WGS11=Ceiling, End Wire Guard VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weatherproof Energy Data Incandescent Exits Input Power: Input Current(Max.): 120V 277V 120V 277V Incandescent Exits -15W Lamps 23.1W 30.0W .19A .19A Incandescent Exits -7W Lamps 12.5W 19.6W .10A .17A Fluorescent Exits Fluorescent Exits -5W Lamps 16.3W 24.4W .14A .33A Fluorescent Exits - 7W Lamps 18.0W 26.2W .15A .31A Fluorescent Exits -7W Lamps (2C Option) 8.7W 13.3W .16A .14A All ratings are per circuit LED Exits LED Exits- Red Letters 1.8W 2.6W .09A .11A LED Exits - Green Letters 3.2W 4.5W .08A .10A Power Factor: 120V 277V T.H.D.: 120V 277V >.97 >.97 >.45 >.27 >.33 >.34 <20% <25% <23% <29% <11% <28% >.17 >.33 >.09 >.15 <18% <10% <28% <16% > UL 924 Listed, Life Safety NFPA 101, CSA Certified, NEC/OSHA, most state and local codes, suitable for floor proximity installation 1Available only for incandescent and fluorescent versions. GWO, RWO, WGO, and WRO are open face style lenses with “EXIT” legend. Use “O” option for ordering special wording-lenses ordered separately (consult your Cooper Lighting Representative). 52 COOPER LIGHTING DIMENSIONS DESCRIPTION Commercial The CCX Series Contractor’s Choice Exit is an economical, attractive, alternative to metal exits. Contemporary round corner styling, designer finish, and consistent family appearance enables it to blend with any decor. The tough injection molded polycarbonate materials resist discoloration. The canopy and chevron directional indicators are of snap-fit construction to facilitate installation. EXIT SIGNS > SURE-LITES® CCX SERIES Po l yc a r b o n a te S e l f - Powe re d EXIT LIGHTING O R D E R I N G I N F O R M AT I O N > Dual-voltage input 120/277VAC, 60Hz SAMPLE NUMBER: CCX30RWHSD CCX Family CCX=Contractor’s Choice Exit Series 3=Self-Powered with 145V, 15W T-6 AC Incandescent Lamps 5=Self-Powered with 5W F5TT Compact Fluorescent Lamps 7=Self-Powered with LED Lite Stix™ Face Options 0=Universal 1=Single Face 2=Double Face Battery Blank=Lead Calcium 70=Nickel Cadmium Factory Options Blank=No Options 20=Flasher 30=Flasher / Buzzer 65=Tamperproof Screws 90=Self-Powered Fire Alarm Interface (except fluorescent) Letter Colors 1 R=Red G=Green RWO=Red on White1 GWO=Green on White1 WRO=White on Red1 WGO=White on Green1 O=Open Face1 Housing Finishes BK=Black (Fluorescent Only) WH=White Voltage Blank=120/277 VAC 47=120/347 VAC (Series 3 and 7 only) Factory Options C7=130V, 7W C-7 AC Incandescent Lamps (Incandescent Only) 7W=7W Compact Fluorescent Lamps (Compact fluorescent Only) SD=Self-Diagnostics Accessories (Order Separately) CCX18PKBK=18” Pendant Kit, Black CCX18PKWH=18” Pendant Kit, White CCX18PKHTBK=18” Hang-True Pendant Kit, Black CCX18PKHTWH=18” Hang-True Pendant Kit, White VRSD=Tamper Resistant Screwdriver WG10=Surface, Wire Guard WGS11=Ceiling, End Wire Guard VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weatherproof > Injection molded, high impact, polycarbonate housing > Designer white textured finish standard (black availablefluorescent only) > LED, Fluorescent, or Incandescent lamping > AC LED: long life LED lamp modules > AC fluorescent: two 5W F5TT lamps > AC incandescent: two 145V, 15W T6 lamps (candelabra base) > DC: two 6V, 3.6W lamps (white housing); three 6V, 3.6W lamps (black housing) > Lead Calcium or Premium Nickel Cadmium battery > Ceiling, wall or end mounting Energy Data Charge Mode (Discharged Battery): Sealed Lead Calcium Battery Input Power: Input Current(Max.): Power Factor: 120V 277V 120V 277V 120V 277V Incandescent Exits -15W Lamps 32W 32W .28A .12A >.95 >.95 Incandescent Exits -7W Lamps 22W 22W .20A .09A >.91 >.90 Fluorescent Exits -5W Lamps 25W 25W .23A .10A >.90 >.90 Fluorescent Exits - 7W Lamps 28W 28W .25A .11A >.93 >.92 LED Exits- Red Letters 10.4W 10.8W .10A .04A >.89 >.88 LED Exits - Green Letters 11.9W 12.3W .10A .05A >.96 >.94 T.H.D.: 120V 277V <17% <19% <24% <26% <21% <23% <23% <23% <45% <48% <29% <33% Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 7.5 Watts in the standby operating mode Sealed Nickel Cadmium Battery Incandescent Exits -15W Lamps 26W 26W .24A .10A >.94 >.93 <17% <19% Incandescent Exits -7W Lamps 15.8W 15.9W .15A .06A >.84 >.83 <29% <27% Fluorescent Exits -5W Lamps 19.9W 19.6W .20A .08A >.85 >.84 <29% <31% Fluorescent Exits - 7W Lamps 22W 21W .21A .09A >.89 >.89 <31% <31% LED Exits- Red Letters 4.8W 4.7W .05A .02A >.76 >.73 <63% <68% LED Exits - Green Letters 6.1W 6.0W .06A .03A >.88 >.85 <47% <52% > Universal J-box mounting pattern > Components are snap-fit construction, reinforcing ribs add strength > Snap-fit canopy included > Suitable for floor proximity installation > Line-latching, Solid-State voltage limited charger , Solid-State switching, low-voltage disconnect, brownout circuit, overload/ short-circuit protection, test switch/power indicator light > UL 924 Listed, life safety NFPA 101, CSA Certified, NEC/OSHA, most state and local codes 1Available only for incandescent and fluorescent versions. GWO, RWO, WGO, and WRO are open face style lenses with “EXIT” legend. Use “O” option for ordering special wording-lenses ordered separately (consult your Cooper Lighting Representative). COOPER LIGHTING 53 DESCRIPTION DIMENSIONS The CCX Series Contractor’s Choice Exit is an economical, attractive, alternative to metal exits. Contemporary round corner styling, designer finish, and consistent family appearance enables it to blend with any decor. The tough injection molded polycarbonate materials resist discoloration. The canopy and chevron directional indicators, are of snap-fit construction to facilitate installation. EXIT SIGNS > Commercial SURE-LITES® CCX SERIES CCXH SERIES O R D E R I N G I N F O R M AT I O N Po l yc a r b o n a te S e l f - Powe re d H i g h Powe r (Remote Capacity) Double Heads EXIT LIGHTING > Dual-voltage input 120/277VAC, 60Hz > Injection molded, high impact, polycarbonate housing > Designer white textured finish standard (black availablefluorescent only) > LED, Fluorescent, or Incandescent lamping > AC LED: long life LED lamp modules > AC fluorescent: two 5W F5TT lamps > AC Incandescent: two 145V, 15W T6 lamps (candelabra base) > DC: two 6V, 3.6W lamps (three for black housing) > Heads: two 6V, 9W PAR36 style lamps (7.2W for black) housing) (specify DH in catalog number) > Lead Calcium batteries > Ceiling, wall or end mounting > Universal J-box mounting pattern > Components are Snap-fit construction, reinforcing ribs add strength > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/ short-circuit protection, test switch/ power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes SAMPLE NUMBER: CCX31RWHDH Family CCX=Contractor’s Choice Exit CCXH=High Output Remote capacity Series 3=Self-Powered with 145V, 15W T-6 AC Incandescent Lamps 5=Self-Powered with 5W F5TT Compact Fluorescent Lamps 7=Self-Powered with LED Lite Stix™ Face Options 1 0=Universal 1=Single Face 2=Double Face Factory Options Blank=No Options 20=Flasher 30=Flasher / Buzzer 65=Tamperproof Screws 90=Self-Powered Fire Alarm Interface (for Incandescent & LED) Letter Colors 2 R=Red G=Green RWO=Red on White2 GWO=Green on White2 WRO=White on Red2 WGO=White on Green2 O=Open Face2 Battery Blank=Lead Calcium Housing Finishes BK=Black (Fluorescent Only) WH=White Factory Options C7=130V, 7W C-7 AC Incandescent Lamps (Incandescent only) 7W=7W Compact Fluorescent Lamps (Fluorescent only) SD=Self-Diagnostics Voltage Blank=120/277 VAC 47= 120/347 VAC (for Incandescent & LED) Heads DH=Double Heads DH0=Remote Capacity No Heads DH1L=Single Head Left (near “E” in “EXIT”) DH1R=Single Head Right (near “T” in “EXIT”) DHMRT=MR16 Heads (5W Standard) DHSQ=Square Heads (5.4W Standard) Accessories (Order Separately) CCXDHMBBK=CCX-DH Ceiling Mounting Bracket, Black CCXDHMBWH=CCX-DH Ceiling Mounting Bracket, White VRSD=Tamper Resistant Screwdriver WG2=Wire Guard VS2=Polycarbonate Vandal Shield VS2WP=Polycarbonate Vandal Shield Weatherproof Energy Data Charge Mode (Discharged Battery): Sealed Lead Calcium Battery Input Power: Input Current(Max.): Power Factor: T.H.D.: 120V 277V 347V 120V 277V 347V 120V 277V 120V 277V Incandescent Exits -15W Lamps 35W 34W 22W .30A .13A .13A >.96 >.95 <16% <18% Incandescent Exits -7W Lamps 24W 25W 29.1W .22A .10A .14A >.93 >.92 <21% <23% Charge Mode (Discharged Battery): Sealed Lead Calcium Battery Fluorescent Exits -5W Lamps 28W 28W .25A .11A >.93 >.93 <19% <21% Fluorescent Exits - 7W Lamps 30W 30W .26A .12A >.94 >.93 <21% <23% Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 5 Watts in the standby operating mode Charge Mode (Discharged Battery): Sealed Lead Calcium Battery LED Exits- Red Letters 12.6W 13.2W 7.0W .11A .05A .09A >.91 >.91 <39% <42% LED Exits - Green Letters 15.8W 15.4W 8.4W .14A .06A .09A >.97 >.96 <25% <29% Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 5 Watts in the standby operating mode WAT TA G E R AT I N G S CCX-DH 1Exits Lead Calcium Battery=27W for 1 1/2 hrs.; 24W for 2 hrs. CCXH-DH Lead Calcium Battery=32W for 1 1/2 hrs. using two faces must also use CCXDHMB Mounting Bracket for ceiling mounting (included in Universal and Double Face configurations). 2Available only for incandescent and fluorescent versions. GWO, RWO, WGO, and WRO are open face style lenses with “EXIT” legend. Use “O” option for ordering special wording-lenses ordered separately (consult your Cooper Representative). 54 COOPER LIGHTING DIMENSIONS DESCRIPTION Wa l l M o u n t End Mount Commercial The EEX Series Surface Mounted Edge-lit Exit, with the Tri-Mount™ System, provides an attractive yet easy to install universal edge-lit exit sign. The crystal clear wedge shape lens panel provides excellent light distribution, exit visibility and quick snapin installation. Long life, energy-efficient LED lamps reduce energy costs and eliminate routine lamp maintenance. EXIT SIGNS > SURE-LITES® EEX SERIES The under-five-minute installation time makes it the fastest installed edge-lit exit on the market today. Edge-Lit S u r fa c e AC Only S e l f - Powe re d Note: Special wording available; consult your Cooper Lighting Representative. EXIT LIGHTING > Dual-voltage Input 120/277 VAC, 60Hz, optional 2C (FTBR) available (EEX6 only) > Injection molded polycarbonate housing > Injection molded, highimpact, clear acrylic panel O R D E R I N G I N F O R M AT I O N – C O M P L E T E U N I T SAMPLE NUMBER: EEX71R > LED lamping EEX Family EEX=Edgelit Exit Series Series 6=LED Lamps, AC Only 7=LED Lamps, SelfPowered Face Options 1=Single Face 2=Double Face Chevron Direction Letter/ Background Blank=Universal Stick-On Color 1 Chevrons R=Red G=Green Battery Blank=No Battery (EEX6) Blank=Nickel Cadmium (EEX7) Housing Trim Finish Blank=White Only Options 2C2=Two Circuit Option FTBR (EEX6 only) Accessories (Order Separately) WG=Choose size of wire guard desired from accessories sheet > Sealed nickel cadmium, maintenance free, long life battery (EEX7 only) > Full Recharge Time, 24 hrs. (max.) > Components are snap-fit construction to facilitate under 5-minute installation > Tri-mount system for ceiling, wall or end mounting > Universal, field installable chevrons E n e rgy Da t a — S e l f - Powe re d E x i t s Charge Mode (Discharged Battery): Sealed Nickel Cadmium Battery Input Power: Input Current (Max.): Power Factor: 120V 277V 120V 277V 120V 277V LED Exits LED Exits Red Lights LED Exits Green Lights 6.5W 4.0W 6.6W 4.1W .08A .07A .04A .03A >.67 >.47 >.66 >.47 T.H.D.: 120V 277V <41% <43% <48% <50% Energy Data — AC Only Input Power: LED Exits -Red Letters LED Exits -Green Letters 120V 277V 5.9W 3.2W 6.0W 3.3W Input Current (Max.): 120V 277V LED Exits .08A .07A .04A .03A Power Factor: T.H.D.: 120V 277V 120V 277V >.62 >.39 >.62 >.39 <43% <51% <45% <53% > Universal background mirror and white inserts included > Universal J-box mounting pattern > Self-powered Exits feature line-latching, solid-state voltage limited charger, solid-state switching, brownout circuit, low-voltage disconnect, overload/ short-circuit protection, test switch / power indicator light > Damp Location Listed (AC only) > UL 924 Listed, UL Listed for floor proximity, UL Listed for Two Circuit (FTBR) (EEX6 only), Life Safety NFPA 101, CSA Certified, NEC/OSHA, most state and local codes 1Universal background clear, white insert and mirror insert included. 2Universal 120/277V normal and 120/277V emergency. COOPER LIGHTING 55 DIMENSIONS DESCRIPTION The EUS Series surface mounted Edge-lit Exit provides an attractive yet easy to install universal edgelit exit sign. The crystal clear lens panel provides excellent light distribution and exit visibility. Long life, energy efficient LED lamps reduce energy costs and eliminate routine lamp maintenance. EXIT SIGNS > Commercial SURE-LITES® EUS SERIES Edge-Lit S u r fa c e All EUS Series Edge-lit Exits are provided with universal mounting capability (ceiling, wall or end), universal exit lens (single and double face), and universal, field installable chevrons. The EUS is the most versatile edge-lit exit in the market today. AC Only S e l f Powe re d EXIT LIGHTING O R D E R I N G I N F O R M AT I O N - C O M P L E T E U N I T SAMPLE NUMBER: EUR70R > Dual Voltage Input 120/277 VAC, 60 Hz > Anodized Aluminum housing, clear acrylic panel or faceplate > LED lamping > Nickel Cadmium battery EU S Family EU=Universal Edgelit Exit Series (Self-Powered) S=Surface Mount > Universal Surface Mount: Series 60=LED Lamps, AC Only 70=LED Lamps, SelfPowered Face Options Blank=Universal Face (Single & Double face) Battery Blank=Lead Acid (Self-Powered Only) Chevron Direction Blank=Universal Stick-On Chevrons Housing Trim Finish Blank=Anodized Aluminum Ceiling, Wall or End > Single and double face panels standard Letter/ Background Color1 R=Red G=Green > Universal, Field Installable Chevrons > Mirror background included with double face exits > Test Switch/Power Indicator Light (Self powered) > UL 924 Listed, ETL Listed, Life Safety NFPA 101, most state and local codes E N E R G Y D ATA Charge Mode (Fully Charged Battery): LED Exits - Red LED Exits - Green LED Exits - Red LED Exits - Green 56 COOPER LIGHTING Sealed Lead Acid Battery Input Power: Input Current(Max.): 120V 277V 120V 277V 3.6W 3.1W .03A .02A 2.9W 2.7W .02A .02A AC Only 3.9W 3.5W .03A .02A 3.1W 2.8W .02A .02A Voltage Blank=Dual Voltage, 120/277V DESCRIPTION DIMENSIONS Commercial The EUR Series Recessed Edgelit Exit provides an attractive yet easy to install universal edgelit exit sign. The crystal clear lens panel provides excellent light distribution and exit visibility. Long life, energy efficient LED lamps reduce energy costs and eliminate routine lamp maintenance. EXIT SIGNS > SURE-LITES® EUR SERIES E d ge - L i t Recessed AC O n l y S e l f - Powe re d EXIT LIGHTING O R D E R I N G I N F O R M AT I O N - C O M P L E T E U N I T SAMPLE NUMBER: EUR70R EU > Dual Voltage Input 120/277 VAC, 60 Hz R Family EU=Universal Edgelit Exit Series R=Recessed Mount (Ceiling access mount only) Series 60=LED Lamps, AC Only 70=LED Lamps, SelfPowered Face Options Blank=Universal Face (Single & Double face) Battery Blank=Lead Acid (Self-Powered Only) Chevron Direction Blank=Universal Stick-On Chevrons Housing Trim Finish Blank=Anodized Aluminum Letter/Background Color1 R=Red G=Green Voltage Blank= Dual Voltage, 120/277V > Anodized Aluminum faceplate, clear acrylic panel > LED lamping > Nickel Cadmium battery (Self-Powered) > Recessed ceiling mount (accessible ceiling only) > Single and double face panels standard > Universal, Field Installable Chevrons > Mirror background included with double face exits > Test Switch/Power Indicator Light (Self powered) E N E R G Y D ATA Charge Mode (Fully Charged Battery): LED Exits - Red LED Exits - Green Input 120V 3.6W 2.9W LED Exits - Red LED Exits - Green 3.9W 3.1W Sealed Lead Acid Battery Power: Input Current(Max.): 277V 120V 277V 3.1W .03A .02A 2.7W .02A .02A AC Only 3.5W .03A .02A 2.8W .02A .02A > UL 924 Listed, ETL Listed, Life Safety NFPA 101, most state and local codes COOPER LIGHTING 57 DESCRIPTION The INCX Series Incandescent Exit is an economical, yet attractive, alternative to metal exits. The tough injection molded white thermoplastic material resists discoloration due to age and ultraviolet radiation. The structural components are made even stronger with reinforcing ribs throughout. All components, including canopy and chevron directional indicators, are of snap-fit construction to facilitate installation. EXIT SIGNS > Commercial SURE-LITES® DIMENSIONS INCX20RGWH 4 13/16" [122mm] 5 1/2" [140mm] 7/8" [22mm] 7 3/4" [196mm] INCX SERIES T h e rm o p l a s t i c AC Only S e l f - Powe re d 11 3/4" [298mm] INCX30RGWH 2 1/2" [64mm] 4 13/16" [122mm] 5 1/2" [140mm] EXIT LIGHTING 1" [25mm] > 120 VAC, 60Hz Input Voltage (INCX20RGWH); 120/277 VAC, 60Hz (INCX30RGWH) > Thermoplastic housing 10" [254mm] > Designer white textured finish > Incandescent: Two 130V, 7W C-7 AC incandescent lamps > Lead Calcium battery (Self-Powered) > Ceiling, wall, or end mounting 13" [330mm] 2 3/4" [70mm] > Universal J-box mounting pattern > Universal exits can be field configured as single face or double face includes both red and green lenses > Components are of snap-fit construction to facilitate rapid installation > Reinforcing ribs throughout to provide maximum strength > Snap-out chevron directional indicators > Snap-fit canopy with mounting screws included with all exits > UL damp location listed > UL 924, Life Safety NFPA 101, NEC/OSHA, Most State and Local Codes O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: INCX20RGWH INCX Family INCX= Incandescent Exit Series 2=AC Only with 130V, 7W C-7 AC Incandescent Lamps 3=Self-Powered with 130V, 7W, C-7 AC Incandescent Lamps Housing Finishes WH=White Accessories (Order Separately) VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield, Weather Resistant WG10=Wire Guard for Surface Mount Applications WGS11=Wire Guard for Ceiling or End Mount Applications Energy Data INCX30RGWH COOPER LIGHTING Letter Colors RG=Red/Green Face Options 0=Universal INCX20RGWH 58 Battery Blank=Lead Calcium (INCX30) Input Power: 120V 12W Input Power: 120V 277V 16.3W 14.2W Input Current(Max.): 120V .10A Input Current(Max.): 120V 277V .14A .05A Power Factor: 120V 277V >.97 >.97 T.H.D.: 120V 277V <10% <14% DIMENSIONS DESCRIPTION Commercial The SLX Series Steel LED Exit is the ideal exit for general purpose applications. With an extensive range of field installed accessories, choice of faces, and the variety of possible mounting configurations, this exit can be tailored to fit almost any application. The Sure-Lites Steel LED Exit offers low energy consumption and requires little maintenance due to highly efficient, long life LED lamps. Durable steel construction, attractive styling and high efficiency illumination make this series compatible in commercial, institutional and multi-housing applications. EXIT SIGNS > SURE-LITES® SLX SERIES Steel AC Only S e l f - Powe re d EXIT LIGHTING O R D E R I N G I N F O R M AT I O N > Dual-voltage Input 120/277 or 120/347 VAC, 60Hz SAMPLE NUMBER: SLX70RWH > 20 gauge steel housing > Long life LED lamps provide uniform diffused illumination SLX Letter Colors R=Red G=Green Family SLX=Steel LED Series 6=AC Only with LED Lamps 7=Self-Powered with LED Lamps Face Options 0=Universal Battery Blank=No Battery (SLX6) Blank=Nickel Cadmium Battery (SLX7) Housing Finishes WH=White BK=Black Accessories (Order Separately) Pendant Kit PK18BK=Black, 18" Long PK18WH=White, 18" Long Option SD=Self-Diagnostic (Red LED, White Housing Only) (SLX7 Only) Hang-True Pendant Kit PK18HTWH=White PK18HTBK=Black Factory Options 90=Fire Alarm Interface (available with SD option only.) (SLX7 Only.) > Universal: Both single or double face; ceiling, wall or end mounting Other Accessories WG10=Surface, Wire Guard WGS11=Ceiling, End Wire Guard VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield Weather Resistant PLC2CU=FTBR (2C) Conversion Canopy (SLX6 Only) Voltage Blank=120/277V 47=120/347V Exit Face 1 Blank=Exit Face, NOM Certified SAL=Salida Face, NOM Certified (Not UL Listed) E n e rgy Da t a — S e l f - Powe re d E x i t s Sealed Nickel Cadmium Battery Input Power: Input Current (Max.): Power Factor: T.H.D.: 120V 277V 347V 120V 277V 347V LED Exits 120V 277V 347V 120V 277V 347V LED Exits -Red Letters 3.8W 3.9W 4.2W 035A .016A .014A >.90 > .90 > .88 <21% <21% <22% LED Exits -Green Letters 6.3W 6.5W 6.1W .08A .04A >.71 >.71 <36% <39% <39% .03A > .77 Energy Data — AC Only Exits Input Power: LED Exits -Red Letters LED Exits - Green Letters 1For Input Current (Max.): Power Factor: > Knockouts for chevron directional indicators > Universal styles offer complete installation flexibility with canopy, backplate, and two stencil faces > Self-powered Exit features line-latching, solid-state voltage limited charger, solid-state switching, brownout circuit, lowvoltage disconnect, test switch, LED indicator light > Energy Star Qualified (SLX60RWH, SLX70RWH, SLX70RWHSD) > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes, CSA Certified, NOM Certified T.H.D.: 120V 277V 347V 120V 277V 347V LED Exits 120V 277V 347V 120V 277V 347V 3.3W 3.4W 3.8W 5.0W 5.1W 5.1W .03A .01A .07A .03A > .90 > .90 > .80 > .62 > .62 > .72 < 22% < 22% < 41% < 39% < 42% < 40% .01A .02A > Premium Nickel Cadmium battery (Self-Powered) use in Mexico, add the prefix MEX to the catalog number in addition to the face description (e.g.: MEX-SLX70RWHSAL). COOPER LIGHTING 59 DIMENSIONS DESCRIPTION The Sure-Lites Standard Steel Exit Series is the ideal exit for general purpose applications. With an extensive range of field installed accessories, choice of faces, and the variety of possible mounting configurations, this basic exit can be tailored to fit almost any application. EXIT SIGNS > Commercial SURE-LITES® R/G/OF/PLX SERIES Steel AC Only EXIT LIGHTING > 120 VAC input voltage S T E E L E X I T S – A C O N LY I N C A N D E S C E N T Type Mounting Stencil Face, White Finish Red Green Letters Letters Stencil Face, Black Finish Red Green Letters Letters Stencil Face, Black/Silver Finish Red Green Letters Letters Universal1 Universal Open Face 2 Wall/Ceiling/End Wall/Ceiling/End R2CX3 G2CX4 OF2CX (specify lens) R2CXB3 G2CXB3 OF2CXB (specify lens) R2CXBS3 G2CXBS4 OF2CXBS (specify lens) > 20 gauge steel housing > LED, Fluorescent, or Incandescent lamping > LED: long life LED lamp modules > Fluorescent: two 5W F5TT lamps > Incandescent: two 20W T6 1/2 intermediate base lamps > Universal: both single and double face; ceiling, wall or end mounting S T E E L E X I T S – A C O N LY F L U O R E S C E N T Type Mounting Stencil Face, White Finish Red Green Letters Letters Stencil Face, Black Finish Red Green Letters Letters Stencil Face, Black/Silver Finish Red Green Letters Letters Universal1 Universal Open Face2 Wall/Ceiling/End Wall/Ceiling/End PLX5200RP3 PLX5200GP PLX5200OP (specify lens) PLX5200RB3 PLX5200GB PLX5200OB (specify lens) PLX5200RBS3 PLX5200GBS PLX5200OBS (specify lens) S T E E L E X I T S – A C O N LY L E D (6) Type Universal1 Mounting Wall/Ceiling/End Stencil Face White Finish, Red Letters 120 VAC 277 VAC Stencil FaceStencil Face White Finish, Green Letters 120 VAC 277 VAC Stencil Face Black Finish, Red Letters 120 VAC 277 VAC Black Finish, Green Letters 120 VAC 277 VAC R2CXLED G2CXLED R2CXBLED G2CXBLED R2277CXLED G2277CXLED R2277CXBLED G2277CXBLED O R D E R I N G I N F O R M AT I O N > Knockouts for chevron directional indicators > Universal styles offer installation flexibility with canopy, backplate, and two stencil faces SAMPLE NUMBER: CX395C Model Number See chart > Louvered downlight > Suitable for floor proximity installation > UL FTBR Listed Factory Options 95=AC Only Fire Alarm Interface (Incandescent. Add option number after series: e.g. OF295CX) 2C=Two Circuit Operation (Incandescent & Fluorescent. Add to end of catalog number: e.g. PLX5200OP2C) > Damp Location Listed > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes Accessories (Order Separately) Canopy Kit CAN571=White CAN578=Black Tamperproof Accessories TPK1CP=Tamperproof Screws 0590A638SP=Screwdriver bit for TPK-1-CP Screws Power Pack EPX5000B=Black EPX5000P=White Wire Guard WG10=Surface Wire Guard WGS11=Ceiling, End Wire Guard 277V Conversion Canopy PLC277B=Black PLC277P=White Pendant Kit PK18BK=Black, 18” Long PK18WH=White, 18" Long VS1=Polycarbonate Vandal Shield Energy Data Incandescent Exits Fluorescent Exits 5W Lamps Fluorescent Exits 7W Lamps 60 AC-Only-Incandescent Exits Input Power: Input Current (Max.): Power Factor: 120V 277V 120V 277V 120V 277V 40W 42W .33A .16A AC-Only-Compact Fluorescent Exits 17W 22W .32A .18A >.43 >.44 17W 22W .28A .16A >.53 >.50 T.H.D.: 120V 277V <8% <9% <9% <10% 1Universal Face Exits include two stencil faces, canopy and backplate. 2For Open Face Exits, specify lens desired: 004346SP-red letters, white background; 004347SP - green letters, white background; 004340SP -white letters, red background; 004341SP-white letters, green background; Special wording, consult your Cooper Lighting Representative. Order Separately. 3Standard UL FTBR Listed. 4Standard FWBO; UL FTBR Listed with “2C” Option. COOPER LIGHTING DESCRIPTION DIMENSIONS UN/UNH/PLX SERIES STEEL EXITS – SELF-POWERED INCANDESCENT Type Mounting Universal 1 Universal Open Face 2 Wall/Ceiling/End UN1SRW UN1SGW Wall/Ceiling/End UN1OFW (specify lens) Commercial The Sure-Lites Self-powered Standard Steel Exit Series is the ideal exit for general purpose applications. With an extensive range of field installed accessories, choice of faces and a variety of mounting configurations, this basic exit can be tailored to fit almost any application. EXIT SIGNS > SURE-LITES® Stencil Face, White Finish Stencil Face, Black Finish Stencil Face, Black/Silver Finish Red Letters Green Letters Red Letters Green Letters Red Letters Green Letters UN1SRB UN1SGB UN1OFB (specify lens) UN1SRBS UN1SGBS UN1OFBS (specify lens) Steel S e l f - Powe re d ST E E L E X I T S – S E L F- P OW E R E D I N C A N D E S C E N T W I T H A D D I T I O N A L O U T P U T TO P OW E R R E M OT E S Universal 1 Universal Open Face 2 Wall/Ceiling/End UNH1SRW UNH1SGW Wall/Ceiling/End UNH1OFW (specify lens) UNH1SRB UNH1SGB UNH1OFB (specify lens) UNH1SRBS UNH1SGBS UNH1OFBS (specify lens) PLX6200RB PLX6200GB PLX6200OB (specify lens) PLX6200RBS PLX6200GBS PLX6200OBS (specify lens) STEEL EXITS – SELF-POWERED FLUORESCENT Universal 1 Universal Open Face 2 Wall/Ceiling/End PLX6200RP PLX6200GP Wall/Ceiling/End PLX6200OP (specify lens) ST E E L E X I T S – S E L F P OW E R E D F L U O R E S C E N T W I T H A D D I T I O N A L O U T P U T TO P OW E R R E M OT E S Universal 1 Universal Open Face 2 Wall/Ceiling/End Wall/Ceiling/End PLX7200RP PLX7200GP PLX7200OP (specify lens) PLX7200RB PLX7200GB PLX7200OB (specify lens) PLX7200RBS PLX7200GBS PLX7200OBS (specify lens) STEEL EXITS – SELF-POWERED LED Type Mounting Stencil Face, White Finish, Red Letters Stencil Face, White Finish, Green Letters Stencil Face, Black Finish, Red Letters Stencil Face, Black Finish, Green Letters Universal 1 Wall/Ceiling/End UN1SRWLED UN1SGWLED UN1SRBLED UN1SGBLED EXIT LIGHTING > Dual-voltage input 120/277VAC, 60Hz > 20 gauge steel housing > LED, Fluorescent, or Incandescent lamping > AC LED: long life LED lamp modules-DC: two 6V, 3.6W DC lamps > AC fluorescent: two 5W F5TT lamps-DC: three 6V, 3.6W DC lamps ST E E L E X I T S – S E L F P OW E R E D L E D W I T H A D D I T I O N A L O U T P U T TO P OW E R R E M OT E S Universal 1 Wall/Ceiling/End UNH1SRWLED UNH1SGWBLED UNH1SRBLED UNH1SGBLEDL WAT TA G E R AT I N G S UN UNH PLX-6200 PLX-7200 Lead Lead Lead Lead Calcium=10.8W for 1 1/2 hrs., 7.2W for 2 hrs. Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs. Calcium = 10.8W for 1 1/2 hrs. Calcium = 27W for 1 1/2 hrs.; 24W for 2 hrs. Nickel Nickel Nickel Nickel Cadmium=15W for 1 1/2 hrs; 12W for 2 hrs. Cadmium=24W for 1 1/2 hrs.; 18W for 2 hrs. Cadmium = 15W for 1 1/2 hrs.; 12W for 2 hrs. Cadmium = 24W for 1 1/2 hrs.; 18W for 2 hrs. O R D E R I N G I N F O R M AT I O N Factory Options (For ordering with incandescent, add option numbers in order listed after series; e.g. UNH170200FW. For ordering with fluorescent, replace “00” with option numbers in order listed; e.g. PLX6230RP. For ordering with LED, add option numbers in order listed after series; e.g.UN1702090SRWLED) 70=Nickel Cadmium Batteries 20=DC Flasher 30=DC Flasher/Buzzer 90=DC Fire Alarm Interface (Incandescent and LED Only) SD=Self-Diagnostics (Add to end of catalog number: e.g. UN130SRWSD) > Lead Calcium or Premium Nickel Cadmium battery > Universal: both single and double face; ceiling, wall and end mounting SAMPLE NUMBER: UNH170SRWSD Model Number See chart > AC incandescent: two 20W T6 1/2 intermediate base lamps-DC: two 6V, 3.6W DC Lamps Accessories (Order Separately) FL1=Flasher Kit BZ1=Buzzer Kit Pendant Kit: PK18BK=Black, 18” long PK18WH=White, 18” long Canopy Kit: CAN571=White CAN578=Black Tamperproof Accessories: TPK1CP=Tamperproof Screws 0590A638SP=Screwdriver bit for TPK1CP Screws Wire Guard WG10=Surface Wire Guard WGS11=Ceiling, End Wire Guard VS2=Polycarbonate Vandal Shield VS2WP=Polycarbonate Vandal Shield Weatherproof Energy Data Charged Mode (Fully Discharged Battery) Sealed Lead Calcium Battery Input Power: Input Current (Max.): Power Factor: T.H.D.: 120V 277V 120V 277V 120V 277V 120V 277V Incandescent Exits 20W Lamps 53W 51W .45A .19A >.99 >.98 <9% <10% Fluorescent Exits 5W lamps 33W 33W .44A .18A >.62 >.65 <10% <8% Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by approximately 7.5 Watts in the standby operating mode Sealed Lead Calcium Battery Incandescent Exits 20W Lamps 47W 44W .40A .16A >.98 >.98 <8% <8% Fluorescent Exits 5W lamps 26W 26W .41A .16A >.52 >.57 <11% <10% Charged Mode (Fully Discharged Battery) Sealed Lead Calcium Battery LED Exits Red Letters (UN) 10.4W 10.8W .10A .04A >.89 >.88 <45% <48% LED Exits Red Letters (UNH) 12.6W 13.2W .10A .05A >.91 >.91 <39% <42% LED Exits Green Letters (UN) 11.9W 12.3W .10A .05A >.96 >.94 <29% <33% LED Exits Green Letters (UNH) 15.8W 15.4W .14A .06A >.97 >.96 <25% <29% Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 7.5 Watts in the standby operating mode Sealed Nickel Cadmium Battery LED Exits Red Letters (UN) 4.8W 4.7W .05A .02A >.76 >.73 <63% <68% LED Exits Red Letters (UNH) 9.1W 9.1W .08A .04A >.90 >.89 <36% <40% LED Exits Green Letters (UN) 6.1W 6.0W .06A .03A >.88 >.85 <47% <52% LED Exits Green Letters (UNH) 10.3W 10.3W .09A .04A >.96 >.95 <24% <29% > Knockouts for chevron directional indicators > Universal styles offer complete installation flexibility with canopy, backplate, and 2 stencil faces > Louvered downlight > Suitable for floor proximity installation > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes 1Universal Face Exits include two stencil faces, canopy and backplate. 2For Open Face Exits, specify lens desired: 004346SP-red letters, white background; 004347SP - green letters, white background; 004340SP - white letters, red background; 004341SP-white letters, green background; Special wording, consult your Cooper Lighting Representative. Order Separately. COOPER LIGHTING 61 DIMENSIONS DESCRIPTION The Sure-Lites UNH/PLX Series Steel Exits combine a self powered exit sign with an emergency light. With an extensive range of field installed accessories, choice of faces and the variety of mounting configurations, this exit can be tailored to fit almost any application. EXIT SIGNS > Commercial SURE-LITES® UNH/PLX SERIES Steel S e l f - Powe re d w i t h Emergency Heads INCANDESCENT EXITS Type Mounting Stencil Face, White Finish Red Letters Green Letters Stencil Face, Black Finish Red Letters Green Letters Stencil Face, Blk/Silver Finish Red Letters Green Letters EXIT LIGHTING Universal 1 Wall/Ceiling/End Wall/Ceiling/End UNH1SRWDH UNH1SGWDH UNH1OFWDH (specify lens) UNH1SRBDH UNH1SGBDH UNH1OFBDH (specify lens) UNH1SRBSDH UNH1SGBSDH UNH1OFBSDH (specify lens) PLX7202RB PLX7202GB PLX7202OB (specify lens) PLX7202RBS PLX7202GBS PLX7202OBS (specify lens) Universal Open Face 2 > Dual-voltage input 120/277VAC, 60Hz FLUORESCENT EXITS > 20 gauge steel housing Universal1 Universal Open Face 2 > LED, Fluorescent, or Incandescent Lamping LED EXITS > AC LED: long-life LED lamp modules; DC: two 6V, 3.6W DC lamps Wall/Ceiling/End Wall/Ceiling/End PLX7202RP PLX7202GP PLX7202OP (specify lens) Type Mounting Stencil Face, White Finish, Red Letters Stencil Face, White Finish, Green Letters Stencil Face, Black Finish, Red Letters Stencil Face, Black Finish, Green Letters Universal Wall/Ceiling/End UNH1SRWDHL UNH1SGWDHL UNH1SRWBDHL UNH1SGWBDHL WAT TA G E R AT I N G S > AC fluorescent: (2) 5W F5TT lamps - DC: three 6V, 3.6W DC lamps > AC incandescent: (2) 20W T6 1/2 intermediate base lamps - DC: two 6V, 3.6W DC lamps > Two thermoplastic heads with matching finish > Heads: 6V, 9W wedge base style lamps (7.2W nickel cadmium exits) PLX-7202 UNH O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: UNH1SRWDHSD Model Number See chart > Lead Calcium or Premium Nickel Cadmium batteries > Universal: both single and double face; ceiling, wall and end mounting > Knockouts for chevron directional indicators > Universal styles include canopy, backplate, and two stencil faces > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/ short-circuit protection, test switch/power indicator light > UL 924 Listed, life safety NFPA 101, NEC/OSHA, most state and local codes COOPER LIGHTING Factory Options (For ordering with incandescent and LED, add option numbers in order listed after series; e.g. UNH17090SRBDHL. For ordering with fluorescent add option numbers in order listed after “PLX7202”; e.g. PLX720270GP.) 70=Nickel Cadmium Batteries 20=DC Flasher 30=DC Flasher/Buzzer 90=DC Fire Alarm Interface (Incandescent & LED) SD=Self-Diagnostics (Add to end of catalog number; e.g. PLX7202RPSD) Accessories (Order Separately) FL1=Flasher Kit BZ1=Buzzer Kit Pendant Kit PK18-BK=Black, 18" long PK18-WH=White, 18" long Canopy Kit CAN571=White CAN578=Black Tamperproof Accessories TPK1CP=Tamperproof Screws 0590A638SP=Screwdriver bit for TPK1CP Screws WG2=Wire Guard VS2=Polycarbonate Vandal Shield VS2WP=Polycarbonate Vandal Shield Weatherproof Energy Data Charge Mode (Fully Discharged Battery) Lead Calcium Battery Input Power: Input Current (Max.): Power Factor: T.H.D.: 120V 277V 120V 277V 120V 277V 120V 277V Charged Mode (Fully Discharged Battery) Lead Calcium Battery Incandescent Exits 20W Lamps 53W 51W .45A .19A >.99 >.98 <9% 10% Fluorescent Exits 5W lamps 33W 33W .44A .18A >.62 >.65 <10% <10% LED Exits Red 12.6W 13.2W .11A .05A >.91 >.91 <39% <42% LED Exits Green 15.8W 15.4W .14A .06A >.97 >.96 <25% <29% Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by approximately 7.5 Watts in the standby operating mode Sealed Lead Calcium Battery Incandescent Exits 20W Lamps 47W 44W .40A .16A >.98 >.98 <8% <8% Fluorescent Exits 5W lamps 26W 26W .41A .16A >.52 >.57 <11% <10% LED Exits Red 9.1W 9.1W .08A .04A >.90 >.89 <36% <40% LED Exits Green 10.3W 10.3W .09A .04A >.96 >.95 <24% <29% 1Universal 62 Lead Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs. Nickel Cadmium=24W for 1 1/2 hrs.; 18W for 2 hrs. Lead Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs. Nickel Cadmium=24W for 1 1/2 hrs.; 18W for 2 hrs. Face Exits include two stencil faces, canopy and backplate. 2For Open Face Exits, specify lens desired: 004346SP-red letters, white background; 004347SP - green letters, white background; 004340SP - white letters, red background; 004341SP-white letters, green background; Special wording , consult your Cooper Lighting Representative. Order Separately. DIMENSIONS DESCRIPTION The All Pro Series emergency light (AP2SQ) is the ideal choice when an affordable thermoplastic unit is required for general purpose applications. Its styling and designer finish enables it to blend with any decor. The housing and mounting plate employ snap-fit construction to further improve the installation time. Both lighting heads are fully adjustable, insuring that light can be put where it is needed. ALL PRO EMERGENCY SURE-LITES® AP2SQ SERIES All Pro EMERGENCY LIGHTING > Dual-voltage input 120/277VAC, 60Hz > High impact white thermoplastic housing > Square, two head design > Fully adjustable lamping > Sealed Lead Calcium battery > Test Switch/Power Indicator Light E L E C T R I C A L R AT I N G S Model AP2SQ > Quick connect AC power Rated Wattage to 87 1/2% of Rated D.C. Voltage DC Voltage 1 1/2 Hours 2 Hours 6 10.8 7.2 Lamp Information Type Wattage Incandescent 5.4 Number 29-121 connector facilitates installation > Suitable for wall or ceiling mount applications > ETL Indoor Damp Location O R D E R I N G I N F O R M AT I O N Listed SAMPLE NUMBER: AP2SQ > UL 924 Listed, Life Safety AP2SQ Model Number AP2SQ Housing Finish Blank=White Accessories (Order Separately) WG-1= Wire Guard VS1= Polycarbonate Vandal Shield VS1WP= Polycarbonate Vandal Shield Weather Resistant NFPA 101, CSA Certified, NEC/OSHA, most state and local codes COOPER LIGHTING 63 ALL PRO EMERGENCY SURE-LITES® DIMENSIONS DESCRIPTION AP SERIES The All Pro Series exit (AP60/70) is the most economical LED exit for general purpose applications. The durable, injection molded, thermoplastic material resists discoloration due to UV radiation and the energy efficient, low maintenance LED's provide bright illumination. All AP series exits offer universal configurations (single and double face) and have universal mounting capability (ceiling, wall, end). All Pro AC Only S e l f - Powe re d EXIT LIGHTING > Dual-voltage input 120/277VAC, 60Hz > High impact white thermoplastic housing > AC LED: Long life LED lamps provide uniform diffused illumination O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : A P- 7 0 R AP - > DC: LED DC lamps (Brighter in emergency mode, AP70) Family AP=All Pro Exit > Nickel Cadmium battery (AP70) Series 6=AC Only LED 7=Self-powered with LED > Ceiling, wall, or end mounting > Field selectable chevrons > Universal exits can be field configured as single face or double face 0 Letter Colors R=Red G=Green Housing Finish Blank=White BK=Black Voltage Blank= 120/277 VAC Face Options 0=Universal Battery Blank=Nickel Cadmium (AP70) > Test Switch/Power Indicator Light (AP70) > ETL Damp Location Listed > UL 924 Listed, UL FTBR Listed (2C Only), Life Safety NFPA 101, NEC/OSHA, most state and local codes 64 COOPER LIGHTING E N E R G Y D ATA E N E R G Y D ATA AC Only LED Exits - Red Input Power: 120V = 2.0W 277V = 2.1W LED Exits - Green Input Power: 120V = 2.2W 277V = 2.1W Sealed Nickel Cadmium Battery LED Exits - Red LED Exits - Green Input Power: Input Power: 120V = 3.0W 120V = 3.0W 277V = 3.0W 277V = 3.0W Input Current (Max.): 120V = .02A 277V = .01A Input Current (Max.): 120V = .02A 277V = .01A Input Current (Max.): 120V = .03A 277V = .02A Input Current (Max.): 120V = .03A 277V = .02A Power Factor: 120V = > .89 277V = > .88 Power Factor: 120V = > .88 277V = > .87 Power Factor: 120V = >.91 277V = >.90 Power Factor: 120V = > .92 277V = > .90 T.H.D.: 120V = < 25% 277V = < 31% T.H.D.: 120V = < 26% 277V = < 32% T.H.D.: 120V = <29% 277V = <32% T.H.D.: 120V = < 30% 277V = < 35% 2C=Two Circuit (AP60G Only) Accessories VS=Choose polycarbonate vandal shield desired from accessories sheet WG=Choose size of wire guard desired from accessories sheet DIMENSIONS DESCRIPTION The All Pro Series exit with heads (combo) is the most economical LED exit available in the market for general purpose applications. The durable, injection molded, thermoplastic material resists discoloration due to UV radiation and the energy efficient, low maintenance LEDs provide bright illumination. The AP Series combos are available in universal configurations (single and double face) and have universal mounting capability (ceiling, wall, end). ALL PRO EMERGENCY SURE-LITES® AP SERIES EXIT WITH HEADS All Pro S e l f - Powe re d with Double Heads (Remote Capacity) EXIT LIGHTING > Dual Voltage 120/277 VAC, 60 Hz O R D E R I N G I N F O R M AT I O N > High impact, white, SAMPLE NUMBER: AP70RWHDH AP 7 0 WH Family AP=All Pro Emergency Exit/ Emergency Letter Colors R=Red DG=Premium Deep Green H=High Power (Remote Capability, Red Only) Blank = No Remote Capacity Housing Finishes WH=White Series 7=Self-powered with LED Voltage Blank=120/277 VAC Face Options 0=Universal Battery Blank=Lead Calcium thermoplastic housing DH Heads DH=Double Heads Options SQ=Square Heads (5.4W Lamp) > AC LED: Long life LED Accessories WG=Wire Guard (Choose size of wire guard from accessories sheet) VS=Choose polycarbonate vandal shield desired from accessories sheet lamps provide uniform diffused illumination > DC: LED DC lamps (Brighter in emergency mode) > Heads DC: 6V, 5.4W incandescent wedge base lamps > Lead Calcium battery (11W remote capacity: APH only) > Universal exits can be field configured as single face or double face > Exit can be ceiling, wall or end mounting WAT TA G E R AT I N G S > Field selectable chevrons APH > UL Damp Location Listed with Double heads (DH) has remote capacity of 11 watts for 1 1/2 hrs. > UL 924 Listed, Life Safety E N E R G Y D ATA Standby Mode (Fully charged Battery): Sealed Lead Calcium Battery LED Exits LED Exits - Red Input Power: Premium Deep Green 120V = 4.9W Input Power: 277V = 4.7W 120V = 3.1W 277V = 2.9W Input Current (Max.): Input Current (Max.): 120V = .07A 277V = .03A 120V = .06A Power Factor: 277V = .02A Power Factor: 120V = >.59 277V = >.64 120V = >.41 277V = >.44 T.H.D.: 120V = <45% T.H.D.: 277V = <44% 120V = <49% 277V = <53% NFPA 101, CSA Certified, NEC/OSHA, most state and local codes Charge Mode (Discharged Battery): Sealed Lead Calcium Battery Input Power consumption is increased by approximately 2.7 watts in the charge operating mode for red units and 3.4 watts for green units COOPER LIGHTING 65 Emergency Lights INDUSTRIAL & HAZARDOUS LOCATION > SURE-LITES® DESCRIPTION DIMENSIONS The Sure-Lites UEL NEMA 4X Emergency Light is designed for those emergency lighting applications where ruggedness and dependability are a must. Designed for the most severe environments, the UEL Emergency Light will provide maximum performance against rain, moisture, cold, corrosives and dust. UEL SERIES U LT I M AT E E M E R G E N C Y LIGHT EMERGENCY LIGHTING > NEMA 4X, UL50 Listed > Dual-voltage input 120/277VAC, 60Hz, Isolation Transformer 15 1/4” [389mm] 6 3/16” [157mm] The UEL’s standard features include die cast housing, nickel cadmium battery, self-diagnostics, photocell LASER test and MR16 lamps. In addition, the injection molded, polycarbonate shield provides protection against moisture, rain, and vandalism. (4) Torx head tamperproof screws with center-pin reject provide additional vandalproof security. The unique design and features make the UEL Emergency Light compatible in food processing facilities, outdoor parking garages, walk-in freezers and other indoor/ outdoor severe environments. 6 11/16” [169mm] Laser Test Self-Diagnostics The self-diagnostic unit will automatically perform the tests required by the NFPA 101 Life Safety Code. The system indicates the status of the unit at all times using an LED indicator that is located near the test switch. > Die cast aluminum housing with powder coat finish > UV stable, glass-clear polycarbonate, vandal resistant shield (.150” thick) with Torx head tamperproof screws, stainless steel Verify proper operation of the transfer circuit and emergency lamps with a convenient laser pointer (sold as an accessory). > (2) Adjustable 12W, MR16 lamps SPLASH ZONE > Nickel Cadmium Battery > Fully recharged in 24 hours > Vandal Proof > Watchguard EMS Self-Diagnostic System E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Lamp Information Model DC Voltage 1 1/2 Hours Type Wattage Number Spacing1 UEL1SD 12 24 MR16 12 29-141 50.0' > Photocell Test Switch (requires accessory LASER for activation) > UL 924 Outdoor Wet Location Listed (suitable for wet and damp locations) > T1 Haz Lamp Rating > NSF, National Sanitation Foundation/Splash Zone (for Food Processing) O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: UEL1SD Family UEL1=Nema 4X Emergency Light Housing Finishes Blank=Silver BK=Black WH=White SD=Self Diagnostics (Standard) > Patent Pending COOPER LIGHTING LASER=Key Chain, Red Laser Pointer (activation tested at 30 feet) V=Voltmeter TDM=Time Delay Monitor UXPKA=Pendant Kit Adapter (fitting adapts to 1/2" NPT threaded pendant) VRSD=#8 Centerpin Torx Screwdriver Energy Data Model No. UEL1SD 1The 66 Accessories (order separately) A=Ammeter HAZ=Hazardous Locations (Class I, Division 2, Groups A, B, C, D) > IP66, Ingress Protection from IEC (International Electrical Commission) > Cleanroom Class 10,000 Options Input Current (Max.): 120V 277V .09A .03A "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 feet ceiling with a 6 feet wide walkway and 3 feet path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance. DESCRIPTION DIMENSIONS The NCB Series is a premium grade emergency lighting system with all metal construction that combines functional styling and power performance capability. These units contain serviceable nickel cadmium batteries and feature advanced solid-state circuitry. NCB SERIES S e r v i c e a b l e We t C e l l Nickel Cadmium Battery High-Capacity E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Lamp Information Model DC Voltage 1 1/2 Hours 2 Hours 3 Hours 4 Hours Type Wattage Number NCB45 1 NCB90 1 NCB110 1 NCB1290 1 NCB12180 1 NCB12225 1 6 6 6 12 12 12 45 90 110 90 180 225 33 67 82 67 135 168 22 45 55 45 90 112 16 33 41 33 67 84 Incandescent Incandescent Incandescent Incandescent Incandescent Incandescent 9 9 9 9 9 9 29-84 29-84 29-84 29-86 29-86 29-86 > Dual-voltage input 120/277VAC, 60Hz > 18 gauge die-formed steel housing and cover (white) Emergency Lights EMERGENCY LIGHTING INDUSTRIAL & HAZARDOUS LOCATION > SURE-LITES® > Two fully adjustable, high-impact thermoplastic heads standard (white) O R D E R I N G I N F O R M AT I O N > Serviceable wet cell nickel cadmium battery SAMPLE NUMBER: NCB45VTDM > Line-latching, Solid-State Model Number NCB45 NCB90 NCB110 NCB1290 NCB12180 NCB12225 Options (Add as Suffix) MH=Metal Heads A=Ammeter TDM=Time Delay Monitor V=Voltmeter Alternate Lamps 2 Other Options 2 Accessories (Order separately) 3MSWH=Mounting Shelf (not applicable for NCB12225) (White Finish) 3BRWH=Mounting Brackets (3-White Finish) WG3=Wire Guard (not applicable for NCB12225) CSK120=Cord Set (120 VAC) CSK277=Cord Set (277 VAC) VS2=Polycarbonate Vandal Shield VS2WP=Polycarbonate Vandal Shield - Weatherproof switching, low-voltage disconnect, brownout circuit, overload/shortcircuit protection, test switch/power indicator light > Knockout, conduit or cord set > Keyhole mounting slots > UL 924 Listed, Life Safety NFPA 101, Listed NEC/OSHA, most state and local codes Energy Data Model No. NCB45 NCB90 NCB110 NCB1290 NCB12180 NCB12225 Input Current (Max.): 120V 277V .45A .17A .50A .20A .81A .34A .84A .37A .72A .30A 1.28A .55A Note: 0, 1, 2, 3 and 4 Heads also available. Specify after catalog number (i.e., NCB12180408) 1Battery shipped separate but automatically included with unit NCB45 - Qty. 1 02625 battery NCB1290 NCB90 - Qty. 1 02626 battery NCB12180 NCB110 - Qty. 2 026129 battery NCB12225 2Consult your Cooper Lighting Representative. - Qty. 2 - Qty. 2 - Qty. 2 02625 battery 02626 battery 026129 battery COOPER LIGHTING 67 Emergency Lights INDUSTRIAL & HAZARDOUS LOCATION > SURE-LITES® DIMENSIONS DESCRIPTION The ideal unit for wet environments where an emergency lighting unit will be exposed to water spray, penetrating steam, or dampness. The UMB Series is best suited for use in areas like waste water treatment plants, food processing facilities and most industrial applications. UMB SERIES We t L o c a t i o n EMERGENCY LIGHTING > NEMA 4X > Dual-voltage input 120/277VAC, 60Hz > Grey fiberglass housing > Two top mounted, fully adjustable, grey, high-impact thermoplastic heads standard E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Model UMB1 UMB6 UMB7 UMB8 UMB9 UMB14 UMB15 UMB16 UMB17 DC Voltage 6 6 6 12 12 6 6 12 12 Battery LC LC LC LC LC NC NC NC NC 1 1/2 Hours 18 27 54 36 54 15 24 30 48 2 Hours 15 24 48 30 48 12 18 24 36 Lamp Information 3 Hours 10 18 36 20 36 8 12 16 24 4 Hours 8 14 28 16 28 6 10 12 20 > Glare-free lens with PAR36 sealed beam lamps > Watertight and corrosion resistant O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: UMB6TH > UL Wet location listed (32˚F or 0˚C and above) > Gasketed, internally hinged front cover > Remote capability > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes 68 COOPER LIGHTING Model Number UMB1 UMB6 UMB7 UMB8 UMB9 UMB14 UMB15 UMB16 UMB17 Options (add as Suffix) TDM=Time Delay Monitor TH=Thermal Heater Alternate Lamps 1 Other Options 1 Energy Data Model No. UMB1, UMB6, UMB7 UMB8, UMB9 UMB14 UMB15 UMB16 UMB17 1Consult Input Current (Max.): 120V 277V .12A .05A .30A .13A .06A .03A .07A .04A .13A .06A .15A .07A your Cooper Lighting Representative. Accessories (Order separately) WG7=Wire Guard VS2WP=Polycarbonate Vandal/Weather Shield Type Incandescent Incandescent Incandescent Halogen Halogen Incandescent Incandescent Halogen Halogen Wattage 8 8 8 8 8 7.2 7.2 8 8 Number 29-03 29-03 29-03 29-16 29-16 29-75 29-75 29-16 29-16 DESCRIPTION DIMENSIONS Sure-Lites’ HZU1254 Series self-contained, explosionproof, emergency lighting unit is intended for operation in NEC Class I, Division 1, Groups C, D, and Class II, Division 1, Groups E, F, G environments. The unit includes (2) 12V, 25W lamps and provides a solidstate, emergency lighting system for application in industrial and heavy-duty commercial facilities like petrochemical plants, drilling rigs, offshore platforms, coal mines and preparation facilities, textile mills, lumber yards, painting booths and gasoline stations. HZU1254 SERIES Hazardous Location EMERGENCY LIGHTING Rated Wattage to 87 1/2% of Rated D.C. Voltage Model HZU125425 DC Voltage 1 1/2 Hours 2 Hours 12 54 – 3 Hours O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: HZU125425 Model Number HZU125425 Accessories (Order separately) 12X25HZP=12V, 25W Pendant Mount Remote Head 12X25HZB=12V, 25W Bracket Mount Remote Head Lamp Information 4 Hours – Type Incandescent Wattage Number 25 ZZ13 > NEMA 4, copper-free aluminum housing and natural, textured die cast aluminum finish enclosure Emergency Lights > Dual-voltage input 120/277VAC, 60Hz E L E C T R I C A L R AT I N G S INDUSTRIAL & HAZARDOUS LOCATION > SURE-LITES® > Lamp heads (two heads standard) contains one 12V, 25W DC medium base A-lamp > Copper-free aluminum lamp housing and guard > Sealed Lead Calcium Battery > Watertight neoprene gasketing > One-way breather and drain > Explosion-proof Energy Data Model No. HZU125425 Input Current (Max.): 120V 277V .32A .15A > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/pilot light > UL 924 Listed, Life Safety NFPA 101, NEC Class I, division 1, Groups C, D and Class II, Division 1, Groups E, F, G, OSHA, most state and local codes COOPER LIGHTING 69 Exit Lights INDUSTRIAL & HAZARDOUS LOCATION > SURE-LITES® -49°F to +140°F UX SERIES Ultimate Exit AC Only S e l f - Po w e r e d DESCRIPTION DIMENSIONS The Sure-Lites UX NEMA 4X LED Exit combines the strength and durability of die cast aluminum with architecturally pleasing aesthetics. Designed for the most severe environments, the UX exit will provide maximum performance against rain, moisture, cold, corrosives and dust. Universal configurations (single and double face) and universal mounting provide the ease of one product specifying for any job. The injection molded, clear, polycarbonate shield not only provides protection against moisture and rain, but vandalism as well. (4) Torx® head tamperproof screws with center-pin reject provide additional vandalproof security. The unique design and features make the UX Exit compatible in food processing facilities, outdoor parking garages, walk-in freezers and other indoor/outdoor severe environments. The UX Exit is approved for ambient environments rated from -45°C (-49°F) up to +60°C (+140°F). EXIT LIGHTING > NEMA 4X Listed > Operating temperature -45°C (-49°F) to 60°C (+140°F) > Dual voltage input 120/277 VAC, 60Hz Isolation Transformer > Die Cast aluminum housing with powder coat finish Self-Diagnostics The self-diagnostic unit will automatically perform the tests required by the NFPA 101 Life Safety Code. The system indicates the status of the unit at all times using an LED indicator that is located near the test switch. > LED Lamping > Premium Nickel Cadmium batteries > Exit can be universally mounted ceiling, wall or end SPLASH ZONE > Field selectable chevrons > Universal pattern knockouts on rear of single face housing for direct mounting to junction box Verify proper operation of the transfer circuit and emergency lamps with a convenient laser pointer (sold as an accessory). O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: UX61R > Pendant mounting > Watchguard EMS Self-diagnostic system > Laser Testing > T6 HAZ lamp rating > IP66, Ingress Protection from IEC (International Electrical Commission) > UL844, Hazardous Locations (Class 1, Division 2, Groups A, B, C, D) with “HAZ” option > UL FTBR Listed when specified with the “2C” option Family UX=Nema 4X Exit Series 6=AC Only, LED 7=Self-powered Face Options 0=Universal 1 (single and double face) 1=Single Housing Finishes Blank=Silver BK=Black WH=White Factory Options 95=AC Only Fire Alarm Interface 90=DC Only Fire Alarm Interface SD=SelfDiagnostics (Standard for UX7 only) Letter Colors R=Red G=Green Options 2C=Two Circuit Operation, FTBR HAZ=Hazardous Locations (Class 1, Division 2, Groups A, B, C, D) (Both can be ordered) Contains one single face exit and one UXUK. VRSD=Vandal Resistant Screwdriver LASER=Key Chain, Laser pointer (UX7 only), (activated at 30 ft.) Energy Data — AC Only Exits Input Power: LED Exits -Red Letters LED Exits -Green Letters 120V 277V 2.7W 2.3W 3.2W 3.0W COOPER LIGHTING Input Current (Max.): 120V 277V LED Exits .07A .08A Power Factor: T.H.D.: 120V 277V 120V 277V .04A .03A > .30 > .26 > .39 > .36 < 56% < 69% < 54% < 67% .04A .04A > .37 > .34 > .39 > .36 < 64% < 69% < 63% < 67% E n e rgy Da t a — S e l f - Powe re d E x i t s LED Exits > Patents Pending 70 UXUKWH=Converts single face exit to double face exit. Contains (1) red lens, (1) green lens, (1) White Exit Stencil, (1) Vandal Shield & Tamperproof Screws UXPKA=Pendant Kit Adapter (fitting adapts exit to 1/2" NPT threaded pendant "supplied by others") 1 > Cleanrooms Class 10,000 > UL 924 Wet Location (Suitable for wet and damp locations), Life Safety NFPA 101, Meets most state and local codes UXUK=Converts single face exit to double face exit. Contains (1) red lens, (1) green lens, (1) Standard Silver Exit Stencil, (1) Vandal Shield & Tamperproof Screws UXUKBK=Converts single face exit to double face exit. Contains (1) red lens, (1) green lens, (1) Black Exit Stencil, (1) Vandal Shield & Tamperproof Screws > Suitable for Floor Proximity Installation, UL Listed, ADA (American Disabilities Act) > NSF National Sanitation Foundation / Splash Zone (for Food Processing) Accessories (Order Separately) LED Exits -Red Letters LED Exits -Green Letters 3.4W 3.1W 3.2W 3.0W .07A .08A DESCRIPTION DIMENSIONS The UMX Series watertight and corrosion-resistant exit with tough polycarbonate lens is designed for use where rain, moisture, dust or corrosives are present. Economical long life fluorescent lamps provide highly visible signage and downlighting. The vibration resistant lamps make the UMX perfect for heavy industrial applications (NEMA 4X Listed). We t L o c a t i o n AC Only S e l f - Powe re d O R D E R I N G I N F O R M AT I O N — A C O N LY E X I T S Voltage Double Arrow UMX5 UMX51 Green Letters/White Background No Left Right Arrow Arrow Arrow UMX3 UMX2 UMX4 UMX31 UMX21 UMX41 Double Arrow UMX1 UMX11 EXIT LIGHTING > NEMA 4X Listed O R D E R I N G I N F O R M AT I O N > Dual-voltage input 120/277VAC, 60Hz SAMPLE NUMBER: UMX7 Exit Lights 120 VAC 277 VAC Red Letters/White Background No Left Right Arrow Arrow Arrow UMX7 UMX6 UMX8 UMX71 UMX61 UMX81 UMX SERIES INDUSTRIAL & HAZARDOUS LOCATION > SURE-LITES® > Gray fiberglass housing Model Number See chart > Tough, high contrast polycarbonate lens Accessories (Order Separately) WG7=Wire Guard Vandal Shield VS2=Polycarbonate Vandal Shield VS2WP=Polycarbonate Vandal Shield/Weather Resistant DC Socket Kit UDC6=Two 6V, 6.6W DC Lamps UDC12=Two 12V, 7.5W DC Lamps > AC: two F6T5 fluorescent lamps > DC: two 6V, 6W DC lamps O R D E R I N G I N F O R M AT I O N — S E L F - P O W E R E D E X I T S Battery Red Letters/White Background No Left Right Arrow Arrow Arrow UMX207 UMX206 UMX208 UMX106 UMX226 Lead Calcium Lead Calcium Battery w/Remote Capability UMX107 Nickel Cadmium UMX227 UMX108 UMX228 Double Arrow UMX205 Green Letters/White Background No Left Right Arrow Arrow Arrow UMX203 UMX202 UMX204 Double Arrow UMX201 UMX105 UMX225 UMX103 UMX223 UMX101 UMX221 UMX102 UMX222 UMX104 UMX224 WAT TA G E R AT I N G S UMX201 – UMX208 UMX101 – UMX108 UMX221 – UMX228 Lead Calcium=18W for 1 1/2 hrs.; 15W for 2 hrs. Lead Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs. Nickel Cadmium=15W for 1 1/2 hrs.; 12W for 2 hrs. O R D E R I N G I N F O R M AT I O N > For operation in ambient temperatures above 32°F > Self-powered Exits feature line-latching, solid-state voltage limited charger, solid-state switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Wet Location Listed SAMPLE NUMBER: UMX207 Model Number See chart > Available with emergency lighting heads mounted on enclosure Factory Options DH=Two 6V, 7.2W Weatherproof Heads (UMX101 thru UMX108 only) TDM=Time Delay Monitor (Exits with Heads only) TH=Thermal Heater for Battery Compartment (For Use w/Lead Calcium Exits) Accessories (Order Separately) WG7=Wire Guard Vandal Shield VS2=Polycarbonate Vandal Shield VS2WP=Polycarbonate Vandal Shield/Weather Resistant > Life Safety NFPA 101, NEC/OSHA, most state and local codes. Energy Data — AC Only Exits Fluorescent Exits-6W Lamps Input Power; 120V 277V 19W 23W UMX Exits Input Current (Max.): 120V 277V .33A .32A Power Factor: 120V 277V >.47 >.26 T.H.D.: 120V 277V <6% <9% E n e rgy Da t a — S e l f - Powe re d E x i t s Charge Mode (Fully Discharged Battery) Sealed Lead Calcium Battery Input Power; Input Current (Max.): Power Factor: T.H.D.: 120V 277V 120V 277V 120V 277V 120V 277V Fluorescent Exits - 6W Lamps 41W 43W .51A .22A >.66 >.69 <14% <14% Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 18 Watts in the standby operating mode. Fluorescent Exits - 6W Lamps 29W Sealed Nickel Cadmium Battery 29W .42A .17A >.57 >.62 <9% <38% COOPER LIGHTING 71 Exit Lights INDUSTRIAL & HAZARDOUS LOCATION > SURE-LITES® DIMENSIONS DESCRIPTION VRX SERIES Thin Profile High-Abuse The VRX Thin Profile HighAbuse Exit Series combines the strength of die cast aluminum, the profile of a recessed design and the superior aesthetics of Sure- Lites LED technology to create an exit with optimum versatility and aesthetics. The VRX Series faceplate/mounting plate/lens is only 1" thick, yielding a sign with minimal off-wall protrusion without requiring the large wall opening of a fully recessed exit. The VRX Series also includes a Remote Powered Exit which can be powered from a VRX Series AC Only or Self Powered Exit. A C O N LY / S E L F - P O W E R E D R E M OT E P OW E R E D AC Only S e l f - Powe re d EXIT LIGHTING O R D E R I N G I N F O R M AT I O N - A C O N LY E X I T S / S E L F - P O W E R E D E X I T S S A M P L E N U M B E R : V R X 6 10 0 0 0 R B > Dual-voltage input 120/277 VAC, 60 Hz > Die cast aluminum faceplate exposed unit thickness is 1” > 20 gauge recessed housing fits in 2x4 construction Product Family VRX=Thin Profile, High Abuse Series Face Options 6=AC Only, 1=Single LED 7=SelfPowered, LED > 18 gauge mounting plate with clearance holes for 1/4" fasteners Battery 00=AC Only, 120/277 (VRX6 only) 70=Nickel Cadmium Battery (VRX7 only) Factory Options Letter Colors 00=No Options R=Red 20=Flasher G=Green (VRX7 only) 30=Flasher/ Buzzer (VRX7 only) 90=DC Fire Alarm Interface (VRX7 only) 95=AC Only, Fire Alarm Interface (VRX6 only) Faceplate Finishes Blank=Brushed Aluminum Face with Black Trim W=White B=Black > LED lamp panel provides uniform light output > Convex .125" polycarbonate Vandal Shield standard O R D E R I N G I N F O R M AT I O N - R E M O T E P O W E R E D L E D E X I T S S A M P L E N U M B E R : V R X 8 10 0 0 0 R B > Centerpin Torx tamper resistant screws > NFPA compliant knockout chevrons allow quick conversion to directional signs Product Family VRX=Thin Profile, High-Abuse Series 8=Remote, LED Face Options 1=Single Battery 00=Remote Powered Factory Options 00=No Options Letter Colors R=Red G=Green > Adjustable hanger bars > EPDM shock-absorbing gasket between mounting plate and wall > Self-powered Exits feature line-latching, solid-state voltage limited charger, solid-state switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, UL Listed as suitable for floor proximity installation, most state and local codes 72 COOPER LIGHTING Faceplate Finishes Blank=Brushed Aluminum Face with Black Trim W=White B=Black Energy Data LED EXITS-AC ONLY Input Power; Input Current (Max.): 120V 277V 120V 277V Red Letters Single Face 5.6W 5.7W .07A .03A Red Letters Single Face with Remote 7.3W 7.3W .07A .03A Green Letters Single Face 6.7W 6.8W .07A .03A Green Letters Single Face with Remote 9.5W 9.7W .09A .04A Remote Powered Red Letters Single Face 2.0 watts additional Green Letters Single Face 2.5 watts additional Power Factor: 120V 277V >.71 >.71 >.83 >.83 >.79 >.79 >.90 >.90 T.H.D.: 120V 277V <36% <36% <33% <34% <30% <31% <26% <27% Power Factor: 120V 277V >.72 >.72 >.84 >.84 >.79 >.79 >.90 >.90 T.H.D.: 120V 277V <34% <34% <31% <32% <30% <31% <26% <26% Energy Data Sealed Nickel Cadmium Battery-LED Exit Input Power; 120V 277V Red Letters Single Face 7.4W 7.5W Red Letters Single Face with Remote 9.3W 9.5W Green Letters Single Face 8.5W 8.7W Green Letters Single Face with Remote 11.4W 11.7W Input Current (Max.): 120V 277V .08A .04A .08A .04A .09A .04A .11A .05A DIMENSIONS DESCRIPTION Tritium self-luminous exits are illuminated by unique phosphor-coated sealed tubes filled with Tritium gas which excites the phosphor causing it to emit visible light. No electrical supply is necessary, thereby eliminating costly electrical wiring, energy and maintenance costs. TRX1 SERIES TRITIUM EXIT Note: Special wording available; consult your Cooper Lighting Representative. TRITIUM SELF-LUMINOUS EXIT LIGHTING O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : T R X 11 R W H 2 0 Family TRX1=Tritium Exit Face Options 1=Single 2=Double Background Colors R =Red G =Green BK=Black Special wording available; consult your Cooper Lighting Representative. Housing and Frame Finishes WH=White BK =Black AL =Aluminum anodized frame and gray housing Rated Life 10=10 years 20=20 years Accessories (Order Separately) CAX18PKWH=18” Pendant Kit, White CAX18PKHTWH=18” Hang True Pendant Kit, White CAX18PKBK=18” Pendant Kit, Black CAX18PKHTBK=18” Hang True Pendant Kit, Black WG1=Surface, Wire Guard VS1=Polycarbonate Vandal Shield IFSP=Institutional impact resistant housing, wall mount only. Exit Lights > Institutional Impact resistant, Flaw resistant housing is comprised of a 13 gauge steel frame with a 3/8" (10mm) thick polycarbonate face INDUSTRIAL & HAZARDOUS LOCATION > SURE-LITES® > The plastic housing is ultrasonically welded to the prismatic diffuser, encapsulating the sealed tubes and reflector without the use of glue > The sealed tubes are made from borosilicate glass which makes the tubes shock resistant > Exit can be ceiling, wall, pendant or end mounted > Field selectable chevrons > Cased in a high-impact flame retardant plastic housing > Tamperproof and vandal resistant > UL 924 (approved to1998 and 2001 requirements). Life Safety NFPA 101. Suitable for Wet Locations. Suitable for use in Hazardous, Explosive, Humid and other Harsh environments. OSHA, NRC. Council of American Building Official (BOCA, ICBO, SBCC1) > Exits are guaranteed for their rated life (10 or 20 years) to exceed minimum illumination requirements, 0.15 foot lamberts I M P O R TA N T Each order placed must include the installation location name and full address for NRC registration purposes. Tritium exits must not be abandoned or disposed of. Call your Cooper Lighting representative for recycling information. COOPER LIGHTING 73 Exit Lights INDUSTRIAL & HAZARDOUS LOCATION > SURE-LITES® DIMENSIONS DESCRIPTION PHL SERIES PHOTOLUMINESCENT EXIT Photoluminescent Self-Luminous Photoluminescent “glow-in-thedark” exits are designed to absorb and store energy from existing light sources. The signs do not require electricity and are non-radioactive, non-toxic, and fire-resistant. This energy efficient exit is ideal for areas where electrical wiring is either difficult or unavailable. It is an excellent choice when adding low level exits. Possible applications include: schools, offices, retail stores and manufacturing plants. The PHL Series exits do not require regular maintenance and have a life expectancy of at least 25 years. EXIT LIGHTING > Energizes from Fluorescent Lighting (Minimum 5 Ft-Candle of Fluorescent Illumination required during building occupancy) > 90 minutes of illumination with a legible viewing distance of at least 50 feet O R D E R I N G I N F O R M AT I O N - A C O N LY E X I T S / S E L F - P O W E R E D E X I T S SAMPLE NUMBER: PHL1RBA Product Family PHL= Photoluminescent Exit Face Options 1=Single 2=Double Letter Colors (Outline) R=Red G=Green Housing Color Blank=Same as Letter Color BA=Brushed Aluminum Accessories PHLS=Clear Acrylic Shield PHLJ=Large Canopy (J-Box) > Heavy duty aluminum housing is impact resistant, corrosion proof and flame retardant > High-brightness strontium oxide aluminate photoluminescent pigment is applied directly onto housing > Non-Radioactive and Non-Toxic > Ceiling, wall or end mounting > Field selectable chevrons > UL 924 Listed, meets Life Safety NFPA 101, ULC Listed, most state and local codes B ru s h e d A l u m i n u m , R e d B ru s h e d A l u m i n u m , G re e n Red Green > Rated Life: 25+ years 74 COOPER LIGHTING DIMENSIONS END MOUNT DESCRIPTION WA L L MOUNT P E N DA N T MOUNT The Sure-Lites HZX Series Explosion-Proof Edgelit Exit signs are designed for use in locations classified as hazardous due to the presence of flammable vapors, gasses or combustible dust. They are suitable for use in Class I, Division 1, Groups C and D, and Class II, Division 1, Groups E, F and G hazardous locations as defined by the National Electrical Code. HZX SERIES Hazardous Location Exit EXIT LIGHTING Model Number HZX21 HZX22 HZX23 Mounting Style Wall End Pendant Sign Panel Single Face Double Face Double Face > Factory-sealed, explosionproof housing of copperfree aluminum Exit Lights > 120 VAC input voltage O R D E R I N G I N F O R M AT I O N INDUSTRIAL & HAZARDOUS LOCATION > SURE-LITES® > Impact-resistant white acrylic edgelit face panel with 6" high red letters N AT I O N A L E L E C T R I C A L C O D E ( N E C ) The National Electrical Code (NEC) defines a hazardous location as “a location where fire hazards or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible dust or ignitable fibers or filings. The Code further separates these hazardous locations into three classes: Class I – locations containing gases and vapors Class II – locations containing dust Class III – locations containing fibers and filings. Each of these classes is broken into divisions. These divisions are separated into groups according to characteristics. Division 1 Hazard Exists – Always present 1 in atmosphere 2 Potential Exists – May be present 1 in atmosphere II Dust 1 Hazard Exists 2 Potential Exists III Fibers 1 Production Areas 2 Handling/Storage Areas > Two 60W, 60T10 clear lamps wired in parallel > No provisions for battery operation > Provides safe operation in the presence of volatile gases, vapor or dust The following chart summarizes these classifications: Class I Gas > Available in pendantmount, wall-mount, or end-mount styles Group A Acetylene B Hydrogen and Manufactured Gases containing Hydrogen C Petrochemicals D Petrochemicals A Acetylene B Hydrogen and Manufactured Gases containing Hydrogen C Petrochemicals D Petrochemicals E Conductive and Combustible Metal Dust F Combustible Carbon Dust G Non-Conductive Combustible Dust Combustible Combustible > Internal rectifier extends lamp life > Relamping tool provided > Listed per UL 844 for hazardous locations up to and including NEC Class I, Division 1, Groups C, D and Class II, Division 1, Groups E, F and G, Life Safety NFPA 101, NEC/OSHA, most state and local codes Energy Data Input Current (Max.): Model No. 120V 277V HZX21, HZX22, HZX23 120W 1.0A ZZ14=60T10 Halogen lamp 120V 60Watt COOPER LIGHTING 75 RETROFIT SURE-LITES® DIMENSIONS DESCRIPTION FBP SERIES When AC power fails, the Sure-Lites FBP Emergency Battery Pack automatically switches to emergency mode. It maintains illumination of one or two lamps for a minimum of 90 minutes. UL924 Listed for field retrofit installation. Fluorescent B a tte r y Pa ck Model Dimensions A 9.4” 9.4” 9.4” 13.3” 13.3” 13.3” 9.4” 9.4” 16.3” 14.1” FBP140X FBP240U FBP240M FBP240H FBP240HU FBP240HSD FBP240C FBP240D FBP3500 FBP450LP B 2.4” 2.4” 2.4” 2.4” 2.4” 2.4” 2.4” 2.4” 5.5” 1.5” C 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” (Flex=28”L) 1.5” (Flex=28”L) 1.7” (Flex=28”L) 1.0” E L E C T R I C A L R AT I N G S A N D O R D E R I N G I N F O R M AT I O N EMERGENCY LIGHTING Model FBP140X > Dual-voltage input 120/277VAC, 60Hz > Universal voltage 120 to 277 VAC, 50/60 Hz (FBP240HU) > Sealed nickel cadmium batteries > Solid-State charger, overload/short-circuit protection, test switch/ power indicator light > Can be installed inside or on top of fixture > May be used with switched or unswitched fixtures FBP240U FBP240M FBP240H FBP240HSD 17W-215W, 2’-8’, T8-T12 HO, VHO, U-shaped, circleline, energy saving, rapid start (4-pin, 2G11, G24q, or GX24q) twin, quad and triple twin-tube compacts COOPER LIGHTING One 600-700 One–20W to 215W (2'-8') One–20W to 39W long compact fluorescent One or Two–20W to 40W (2'-4') One or Two - 17W to 24W One or Two - 32W to 40W (2'-4') One - 40W to 215W (5'-8') One or Two -18W to 39W long compact fluorescent One or Two - 18W to 32W 4-Pin compact fluorescent One or Two-17W to 40W (2"-4") One-40W to 215W (5'-8') One or Two-18W to 39W long compact fluorescent One-40W to 55W long compact fluorescent One or Two-18W to 42W 4-pin compact fluorescent One or Two-17W to 40W (2"-4") One-40W to 215W (5'-8') One or Two-18W to 39W long compact fluorescent One-40W to 55W long compact fluorescent One or Two-18W to 42W 4-pin compact fluorescent One or Two–6W to 28W tubular One or Two–13W to 39W or One–42W 4-pin compact fluorescent 600-700 1100-1400 (700-1000 for long compact fluorescent) 1100-1400 (700-1000 for long compact fluorescent) FBP240C 6W-28W tubular without integral starter, 13W-42W 4-pin twin, quad, or triple twin-tube compact fluorescent without integral starters FBP240D 18W-26W quad tube with integral starter in two pin base One-18W to 26W compact fluorescent 300-650 FBP450LP 32W, 4’, T8 One 450 FBP3500 17W-215W, 2'-8', T-8-T12 HO, VHO, U-shaped circleline, energy saving and (4-pin, 2G11, G24Q, or GX240) twin, quad and triple twin-tube compacts One or Two-17W to 40W (2"-4") One-40W to 215W (5'-8') One or Two-18W to 39W long compact fluorescent One-40W to 55W long compact fluorescent One or Two-18W to 42W 4-pin compact fluorescent 1450-3500 > Low Profile (FBP450LP) 76 Initial Lumens 350-450 17W-215W, 2’-8’, T8-T12 HO, VHO, U-shaped, circleline, energy saving, rapid start (4-pin, 2G11, G24q, or GX24q) twin, quad and triple twin-tube compacts > Self Diagnostic (FBP240HSD) > UL 924 Listed, UL Listed for Retrofit/ Field Installation, Chicago Approved, Life Safety NFPA 101, NEC/OSHA, most state and local codes Number of Lamps Operated in Emergency Mode One FBP240HU > Compatible with many different lamp types > Compatible with many ballast types including standard, rapid-start, slimline, instant-start, energy saving, dimming and electronic AC ballasts consult your Cooper Lighting Representative regarding specific applications Lamp Type 20W-40W, 2'-4', T8-T12 U-shaped, circleline, 2D, energy saving, rapid start (4-pin, 2G11) long compact fluorescent 17W-215W, 2'-8', T8-T12 HO, VHO, U-shaped, circleline, 2D, energy saving, rapid start (4-pin, 2G11) long compact fluorescent 17W-215W, 2’-8’, T8-T12 HO, VHO, U-shaped, circleline, 2D, energy saving, rapid start (4 pin, 2G11) long compact fluorescent 17W-215W, 2'-8', T8-T12 HO, VHO, U-shaped, circleline, energy saving, rapid start (4-pin, 2G11 or G24q) long compact fluorescent O R D E R I N G I N F O R M AT I O N Energy Data SAMPLE NUMBER: FBP140X FBP140X FBP240U FBP240M FBP240H FBP240HSD FBP240HU FBP240C FBP240D FBP3500 FBP450LP Accessories (Order separately) FBP1WBC=Wire Bundle Cover for external mount applications (2 required) Model No. FBP140X FBP240U FBP240M FBP240H FBP240HSD FBP240HU FBP240C FBP240D FBP3500 FBP450LP Input Power 120V 4.5W 5.3W 5.3W 5.8W 4.0W 6.0W 5.3W 3.5W 8.0W 1.5W 1100-1400 (700-1000 for long compact fluorescent) 300-750 DESCRIPTION DIMENSIONS In the event of AC power loss, the Sure-Lites LTC1, Load Transfer Circuit, automatically switches normal light fixtures to approved emergency lights. The LTC1 in conjunction with an auxiliary emergency power generator, will provide emergency power to lighting fixtures regardless of the room switch position. The LTC1 will operate up to a maximum10A load. The LTC1 is UL924 listed for field retrofit installation. RETROFIT SURE-LITES® LTC1 SERIES L o a d Tr a n s f e r C i r c u i t EMERGENCY LIGHTING > 120VAC and 277VAC, 60Hz available > Test Switch/3 LED Indicator Lights for: Utility Power, Emergency Power, Test Modes > Operates incandescent, fluorescent, HID and other loads; 10 Amps Max O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : LT C 11 2 0 V > Sized to fit inside ballast channel LTC1 Family LTC1=Load Transfer Circuit > Matte black painted steel housing with conduit BX connector standard Voltage 120V=120VAC 277V=277VAC > Can be installed inside, on top of fixture or remote from fixture > May be used with switched fixtures > Compatible with many different lamp types > Compatible with many ballast types including standard, rapid-start, slimline, instant-start, energy-saving, dimming and electronic AC ballasts consult Cooper Lighting Representative regarding specific applications > UL 924 Listed (dry locations), UL Listed for Retrofit/ Field Installation, Life Safety NFPA 101, NEC/OSHA COOPER LIGHTING 77 RETROFIT SURE-LITES® DIMENSIONS DESCRIPTION LTC2 SERIES L o a d Tr a n s f e r C i r c u i t EMERGENCY LIGHTING In the event of AC power loss, the SureLites LTC2, Load Transfer Circuit, automatically switches normal light fixtures to approved emergency lights. The LTC2, in conjunction with an auxiliary emergency power generator or inverter, will provide emergency power to lighting fixtures regardless of the room switch position. The LTC2 will operate up to a maximum10A load. The LTC2 is UL924 listed for field retrofit installation. > 120/277VAC, 60Hz available > Operates incandescent, fluorescent, HID and other loads; 10 Amps Max > Matte black painted steel housing > Sized to fit inside ballast channel > Can be installed inside or on top of fixture > May be used with switched fixtures > Compatible with many different lamp types > Compatible with many ballast types including standard, rapid-start, slimline, instant-start, energy-saving, dimming and electronic AC ballastsconsult Cooper Lighting Representative regarding specific applications > UL 924 Listed (dry locations), UL Listed for Retrofit/ Field Installation, Life Safety NFPA 101, NEC/OSHA 78 COOPER LIGHTING O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : LT C 2 LTC2 Family LTC2=Load Transfer Circuit Voltage Blank=120/277VAC DIMENSIONS DESCRIPTION • 120 VAC, 60 Hz input voltage • Long-life, high-output LEDs • Consumes less than 1 watt per lamp (2W per kit) • MOV (Metal Oxide Varistor) surge protected • Patent pending • LEDs (Light Emitting Diodes) are encapsulated in a standard T-6 1/2 glass lamp envelope • Super-clear glass and super-bright LEDs combine for optimum light output • Available in two base styles: candelabra and intermediate • Simple screw-in installation - no special adapters or messy rewiring • Direct replacement for up to 20W incandescent lamps • Two lamps provided per kit The Sure-Lites LED LITE STIX™ LED Retrofit Kit for Exits offers the latest technology in exit lighting available today. The Patent Pending design of the LED LITE STIX™ provides superior illumination of exit lettering at a fraction of the costs associated with typical incandescent lamps. Each kit is provided with two lamps which come in two different base styles to suit nearly every application. Installation is easy since the lamps simply screw into the existing incandescent lamp sockets. The long life characteristic of the LEDs is protected by an integral MOV (Metal Oxide Varistor) surge protection device which is designed to protect the lamp in the event of an electrical surge. Practically any stencil face incandescent exit fixture can be retrofitted with the Sure-Lites LED LITE STIX™ LED Retrofit Kit for Exits, yielding significant energy savings and eliminating the lamp maintenance associated with incandescent lamps. The kit is suitable for use with either single or double face exit fixtures. • No special provisions required for installation: 1. Disconnect AC power and open exit fixture 2. Remove existing AC incandescent lamps 3. Screw-in LED LITE STIX™ 4. Close exit fixture and reconnect AC power • Damp Location Listed • UL 924 Classified for Sure-Lites Exits, Life Safety NFPA 101, CSA Certified, NEC/OSHA, Most state and local codes • Suitable for use with single- or double-face exit fixtures • Eliminates lamp replacement costs and maintenance labor • Trilingual instructions included (English, Spanish, and French) • Diffuser can also be used to convert green exits to red O R D E R I N G I N F O R M AT I O N Energy Data SAMPLE NUMBER: RKRC RKRC, RKRI (per 2-lamp kit) Input Power: 120V = 2.0W Input Current (Max.): 120V = .09A Power Factor: 120V = >.19 T.H.D.: 120V = <19% RK Family RK=LED LITE STIX™ LED Retrofit Kit Lamp Color R=Red Base Style C=Candelabra I=Intermediate Accessories (order separately) RKLR=Diffuser - Red - 13" x 9" RETROFIT SURE-LITES® RKRC SERIES LED Lite Stix™ Exit Retrofit Kit EXIT LIGHTING RKRI SERIES LED Lite Stix™ Exit Retrofit Kit EXIT LIGHTING COOPER LIGHTING 79 RETROFIT SURE-LITES® DIMENSIONS DESCRIPTION REM SERIES Remote Emergency Module EMERGENCY LIGHTING The REM Series is used to convert a non-emergency fixture to an emergency fixture when combined with a 12V DC emergency power source. Provides transfer capability only - module does not contain batteries. REM240 will operate with 12V DC incandescent lamps up to 85W maximum. Each module operates one lamp. E L E C T R I C A L R AT I N G S A N D O R D E R I N G I N F O R M AT I O N Model Battery Used With Rated Wattage Wattage Consumed in Emergency Mode* REM240 None 12V DC Incandescent lamp 85W (Max.) Lamp Wattage plus 0.9W * Lamp wattage included except where noted DIMENSIONS DESCRIPTION RBP SERIES Remote Fluorescent B a tte r y Pa ck The Sure-Lites RBP Series Remote Battery Pack enables the conversion of nearly any standard compact fluorescent fixture into an emergency lighting fixture. The RBP Series is a complete conversion system in that it contains everything required for the conversion including batteries, electronics and test switch. On two lamp fixtures it illuminates one lamp in emergency mode. It may be wired to a switched or unswitched fixture (277VAC applications which use 120V ballasted fixtures require the EMS277 Switching Accessory). EMERGENCY LIGHTING E L E C T R I C A L R AT I N G S Model Battery Used With Initial Lumen Output Emergency Mode Illumination Time RBP9 RBP9347 RBP13 RBP13347 RBP1826 RBP1826347 12V Sealed Lead Calcium 12V Sealed Lead Calcium 12V Sealed Lead Calcium 12V Sealed Lead Calcium 12V Sealed Lead Calcium 12V Sealed Lead Calcium 7W or 9W 2-Pin Compact Fluorescent Lamp (One lamp only) 7W or 9W 2-Pin Compact Fluorescent Lamp (One lamp only) 13W 2-Pin Compact Fluorescent Lamp (One lamp only) 13W 2-Pin Compact Fluorescent Lamp (One lamp only) 18W or 26W 2-Pin Compact Fluorescent Lamp (One lamp only) 18W or 26W 2-Pin Compact Fluorescent Lamp (One lamp only) 98% of lamp rating 98% of lamp rating 98% of lamp rating 98% of lamp rating 98% of lamp rating 98% of lamp rating 120 minutes 120 minutes 120 minutes 120 minutes 120 minutes 120 minutes O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: RBP9 Model Number RBP9 RBP13 RBP1826 80 COOPER LIGHTING Accessories (Order separately) EMS277=Accessory for 277V Switching Applications O R D E R I N G I N F O R M AT I O N 277V Canopy Conversion Kit Catalog Number PLC277P PLC277B AD277CAX AD277CAXW AD277CAXBZ CAN277ELX CCX277 DESCRIPTION Color White Black Black White Bronze N/A N/A For use with R/G/CX/OF/PLX Series Steel Exits R/G/CX/OF/PLX Series Steel Exits CAX Series Exits CAX Series Exits CAX Series Exits ELX Series Exits CCX Series Exits FTBR Conversion Canopy - CAX Series Incandescent Exits (For use with CAX Series AC only, incandescent and screw-in LED exits with brushed aluminum, white or black housing finish) Description Universal Input 120V or 277V 120V Input Only One 120V Input and one 277V Input For use with CAX2100XXG, GB, GW, R, RB, RW and CAX2200XXG, GB, GW, R, RB, RW Finish Codes: B-Black, BZ-Bronze, W-White. Add suffix to Catalog Number when ordering. FTBR Conversion Canopy - Steel Series LED Exits (For use with R/G Series LED fixtures, SLX Series) Catalog Number PLC2CU 277V CONVERSION CANOPIES DESCRIPTION O R D E R I N G I N F O R M AT I O N Catalog Number AD2CUCAX AD2C120CAX AD2C1277CAX PLC/AD/CAN Series Canopy Conversion Kit • Kit for converting 120 VAC Only Exits to 277V operation. • 277 VAC Input, 120 VAC Output • Two transformers included • Allows wiring of AC lamps on separate circuits • PLC Series – 20 gauge steel canopy • AD Series – Die cast canopy • CAN277ELX installs inside standard ELX housing RETROFIT SURE-LITES® Description For use with G1LED, G1CLED, G2CLED, G2CXLED, G1277LED, G2277LED, G2277CLED, G2277CXLED, R1LED, R1CLED, R2CLED, R2CXLED, R1277LED, R2277LED, R2277CLED, R2277CXLED PLC2C120 PLC2C1277 Finish Codes: B-Black, P-White. Add suffix to Catalog Number when ordering. Canopy housing made of 20 gauge steel (PLC Series) or die cast aluminum (AD Series). UL 924,Life Safety NFPA 101, UL FTBR Listed when used with correlated Exit Lights. PLC/AD Series FTBR Conversion Canopies Canopy used to field convert an AC Only Exit which is UL Listed in Category FWBO - Exit Fixtures to an exit which is UL Listed in category FTBR - Emergency Lighting and Power Equipment. Exits employing these canopies are intended to be connected simultaneously to normal and emergency power circuits. Three input voltage types are available: 1) Universal: 120/277V Normal Power and 120/277V Emergency Power 2) 120V Normal Power and 120V Emergency Power 3) 120V Normal Power and 277V Emergency Power or 277V Normal Power and 120V Emergency Power FTBR CONVERSION CANOPIES DESCRIPTION O R D E R I N G I N F O R M AT I O N Catalog Number Suffix FL1 Description DC Flasher BZ1 DC Buzzer For use with CCX, UN, UNH, EAX, PLX, CAX (Incandescent only) and CAR (Incandescent only) UN, UNH, PLX, CAX (Incandescent only) and CAR (Incandescent only) Flasher Kit Kit for flashing the DC lamps of exits during the emergency operation mode. Buzzer Kit Kit provides an audible signal during the emergency operation mode of exits. FLASHER/ BUZZER KIT COOPER LIGHTING 81 RETROFIT SURE-LITES® DESCRIPTION EMERGENCY POWER PACK Standard Emergency Power Pack for converting AC Only incandescent or fluorescent steel exits to self-powered emergency exits (DC lamp kit included). Dual-voltage input 120/277 VAC, 60Hz, line-latching, Solid-state voltage limited charger, SolidState switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light, may be specified with self-diagnostics option (use “SD” suffix). DESCRIPTION CAX EMERGENCY POWER PACK 82 COOPER LIGHTING Emergency Power Pack for converting AC Only Incandescent CAX Series Exits to Self-Powered Emergency Exits (DC Lamp Kit included). Dual-voltage input 120/277 VAC, 60Hz, line-latching, Solid-state voltage limited charger, SolidState switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light. O R D E R I N G I N F O R M AT I O N Emergency Power Pack (Rated Wattage to 87 1/2% of Rated D.C. Voltage) Catalog No. Color 1 1/2 Hours 2 Hours Comments EPX5000P White 10.8 7.2 When used with PLX Series Steel Exits, one additional DC lamp is required (Total: 3 lamps) – Order DCE6 or DCE63 EPX5000B Black 10.8 7.2 (Total: 3 lamps) – Order DCE6 or DCE63 • • • • • • • 22 gauge steel housing Choice of two finishes Sealed lead calcium battery Maintenance free, long life Full recharge time, 24 hrs. (max.) Polarized battery terminals Two 6V, 3.6W DC wedge base lamps included O R D E R I N G I N F O R M AT I O N Emergency Power Pack (Rated Wattage to 87 1/2% of Rated D.C. Voltage) Catalog No. Color 1 1/2 Hours 2 Hours Comments CAX3PP Black 10.8 7.2 CAX Series Incandescent Exits and CAX/LED ACR CAX3PPW White 10.8 7.2 CAX Series Incandescent Exits Only CAX3PPBZ Bronze 10.8 7.2 CAX Series Incandescent Exits and CAX/LED ACR • • • • Die cast canopy with electronics package Choice of three finishes Sealed Lead Calcium Battery, Two 6V, 3.6W DC wedge base lamps included O R D E R I N G I N F O R M AT I O N Cat. No. Length VS1 VS1WP VS2 VS2WP Height DESCRIPTION Depth For use with 21" (533mm) 11" (279mm) 10" (254mm) AA, CAX, CC, CCX (AC only or Self-Powered), CHX (AC only), CU, LM, P4C, PLX (AC only), R/G/CX/OF, CX, LPX (without heads), ST Series; Remote Heads 21" (533mm) 11" (279mm) 10" (254mm) AA, CAX, CC, CCX (AC only or Self-Powered), CHX (AC only), CU, LM, P4C, PLX (AC only), R/G/CX/OF, CX, LPX (without heads), ST Series; Remote Heads 21" (533mm) 19" (483mm) 11" (279mm) CCX (with Heads), CHX (Self-Powered), UN/UNH (Self-Powered or with Heads), HR, NCB (except NCB12225), PLX (Self-Powered or with Heads), LPX (with heads), UMB, XR Series, CC7, CC8 21" (533mm) 19" (483mm) 11" (279mm) CCX (with Heads), CHX (Self-Powered), UN/UNH (Self-Powered or with Heads), HR, NCB (except NCB12225), PLX (Self-Powered or with Heads), LPX (with heads), UMB, XR Series CC7, CC8 Length 18" (457mm) WG2 18" (457mm) WG3 23" (584mm) WG4 WG5 WG6 WG7 32" 16" 26" 16" WG8 WG9 8" (203mm) 16" (406mm) WG10 13 3⁄4" (349mm) WGS11 13 5⁄8" (346mm) WG12 27 1⁄2" (698mm) WG17 27 1⁄2" (698mm) WG19 21" (533mm) (812mm) (406mm) (660mm) (406mm) • Self-adhesive closed-cell neoprene gaskets provided with “WP” weather resistant versions • “WP” weather resistant versions are provided with gasketed breather vent UL 924 Rain Test (SD4.6), UL 924 Water Shield Impact Test (SD4.10) POLYCARBONATE VANDAL SHIELD/ WEATHER SHIELD DESCRIPTION O R D E R I N G I N F O R M AT I O N Catalog No. WG1 • Made of durable, highimpact, UV-resistant clear polycarbonate material ACCESSORIES SURE-LITES® Height 15" (381mm) Depth 6" (152mm) For use with CC, LM1, AA, XR, CU2, CAX (Incandescent/ Fluorescent, Self- Powered, Surface Mount) Series 15" (381mm) 10" (254mm) PLX (with heads), UNH (with heads), CCX (with heads) & CHX (with heads) 20" (508mm) 12" (305mm) HR180, HR12170, HR12210, HR12360, NCB45, NCB90, NCB110, NCB1290, NCB12180 Series, CC7, CC8 21" (533mm) 12" (305mm) NCB12225 Series 16" (406mm) 14" (356mm) SLC1, CFR1 Series 16" (406mm) 14" (356mm) SLC2, CFR2 Series 16" (406mm) 9" (229mm) P4C, RLM, RD, R4C, HR87, HR117, HR12117, UMB, UMX Series 8" (203mm) 8" (203mm) Single Head Remotes 8" (203mm) 8" (203mm) Double Head Remotes, ST1 13 3⁄8" (340mm) 4 3⁄8" (111mm) R, G, CX, UN, UNH, PLX, CCX, SLX, LPX/LPXH, INCX, TRX, CAX (Incandescent/ Fluorescent, AC), CAX-LED Series (Surface Mount Only—CU2), CHX 16 3⁄4" (425mm) 4" (102mm) R, G, CX, UN, UNH, PLX, CCX, SLX, LPX/LPXH, CAX, INCX, TRX Series (End or Ceiling Mount Only), CHX 14" (356mm) 8" (203mm) GC Series, LPX (with heads-wall) 12" (305mm) 14 1⁄2" (368mm) GC Series LPX (with heads-ceiling or wall) 15" (381mm) 6" (152mm) CU1 Series O R D E R I N G I N F O R M AT I O N Wire Guards • All metal wire guard for exits or emergency units • .177" (5mm) diameter 7 gauge steel round wire • Non reflective zinc plated finish • Hinged sides hook in place (except WGS11 which is not hinged) • Screw eyes provided for mounting WIRE GUARDS DESCRIPTION Pendant Kits Catalog No. PK18WH Finish White Length 18" PK18BK Black 18" CCX18PKWH CCX18PKBK CAX18PKWH White Black White 18" 18" 18" CAX18PKBK Black 18" CAX18PKBZ Bronze 18" For use with R/G/CX/OF/SLX/UN/UNH/ PLX Series Steel Exits R/G/CX/OF/SLX/UN/UNH/ PLX Series Steel Exits CCX/LPX Series Exits CCX/LPX Series Exits CAX Series Exits with incandescent or compact fluorescent lamps which are 120/277VAC Only or are self-powered emergency; all CAX Series Exits with LED lamps, CX6 & CX7 Series, HR Series and CU2 Series Pendant Kit • Pendant Kit for pendant mounting of exits • No electrical components • Includes canopy, mounting hardware, threaded stem and attachment bracket • CAX Series Pendant Kit may require CAX Series Splice Box PENDANT KITS Note: Contact Cooper Lighting Representative for Custom Lengths COOPER LIGHTING 83 ACCESSORIES SURE-LITES® DESCRIPTION HANG-TRUE PENDANT KIT Hang-True Pendant Kit • Pendant Kit for mounting of exit signs on sloped ceilings up to 45° • No electrical components • Includes canopy, mounting hardware, threaded stem and attachment bracket • CAX Series Hang-True Pendant kit may require CAX Series splice box O R D E R I N G I N F O R M AT I O N Hang-True Pendant Kits PK18HTWH White 18" PK18HTBK Black 18" CCX18PKHTWH CCX18PKHTBK CAX18PKHTWH White Black White 18" 18" 18" CAX18PKHTBK Black 18" CAX18PKHTBZ Bronze 18" R/G/CX3/OF/UNH/PLX/SLX Series Steel Exits R/G/CX3/OFUNH/PLX/SLX Series Steel Exits CCX/LPX Series Exits CCX/LPX Series Exits CAX Series Exits with incandescent or compact fluorescent lamps which are 120/277VAC Only or are self-powered emergency; all CAX Series Exits with LED lamps, CX6 & CX7 Series and CU2 Series Note: Contact Cooper Lighting Representative for Custom Lengths DESCRIPTION CANOPY KITS Canopy Kit • Canopy for end or top mounting of exits. No electrical components • CAN Series – Impact-resistant, injection molded thermoplastic • QE Series – Die cast 380 aluminum alloy • Includes mounting plate and mounting hardware DESCRIPTION CAX SERIES SPLICE BOX 84 COOPER LIGHTING CAX Series Splice Box • Splice Box provides wire splicing compartment for CAX Series Exits with incandescent or compact fluorescent lamps which are 277V AC Only or are self-powered and employ a CAX Series Pendant Kit. Note: This accessory is not required for CAX-LED Series Exits O R D E R I N G I N F O R M AT I O N Canopy Kits Catalog No. CAN571 CAN578 Finish White Black For use with R/G/CX3/OF/UN/UNH/PLX/SLX Series Steel Exits R/G/CX3/OF/UN/UNH/PLX/SLX Series Steel Exits O R D E R I N G I N F O R M AT I O N CAX Series Splice Box Catalog No. CAXSBOXWHSP Finish White CAXSBOXBKSP Black CAXSBOXBZSP Bronze For use with Required for CAX Series Exits with incandescent or compact fluorescent lamps which are 277V AC Only or are self-powered and utilize any CAX Series Pendant Kit 277V AC Only or are self-powered and utilize any CAX Series Pendant Kit DESCRIPTION O R D E R I N G I N F O R M AT I O N Catalog No. EMS277 • • • • Description 277V Switching Accessory For use with H-274-EM, RBP Series No electrical components 18 gauge die formed steel Specify white, black, or bronze finish Installs directly to Pendant Kit stem and above 277V canopy or self-powered power pack For use with Almost any emergency unit or self-powered exit O R D E R I N G I N F O R M AT I O N Cordsets Catalog Number CSK120 CSK277 Voltmeter Catalog Number VK1 SWITCHING ACCESSORIES DESCRIPTION O R D E R I N G I N F O R M AT I O N Remote Test Switch & Pilot Light Catalog No. Description 1RTPL Remote Test Switch & Pilot Light 277V Switching Accessory Switching Kit required for 277V installations with RBP Series, H274EM. Enables fixture to be turned off without activating the emergency mode while maintaining a charge to the batteries. If a power failure occurs, the fixture switches to emergency mode and illuminates. 277 VAC operation. Requires switched and unswitched 277 VAC connections.One EMS-277 Switching Accessory required per fixture to be switched. Mounts to fixture junction box. ACCESSORIES SURE-LITES® Description 120V Cordset 277V Cordset with standard NEMA L7-20P plug Description Voltmeter (Range: 0-15 Volts) Remote Test Switch & Pilot Light • Supplied with wiring pigtails • Power indicator lamp • Test switch allows battery and lamp check from remote location • Wires to 120 VAC • Check local codes for maximum fixture to test switch distance REMOTE TEST SWITCH & PILOT LIGHT DESCRIPTION Cordsets • Accessory Cordsets for use with units and unswitched 24- hour supply outlets.120V or 277V three prong 3' cordsets • Field Installed Voltmeter allows check of battery output. Voltage range is 0-15 Volts. Provides convenient indication of battery voltage CORDSETS COOPER LIGHTING 85 ACCESSORIES SURE-LITES® DESCRIPTION Mounting Brackets & Shelves • Mounting Brackets and Shelves simplify installation of Emergency Lighting Units • 18 gauge steel brackets, 20 Gauge steel Shelves • Available in Grey, Black and White finishes – specify color when ordering O R D E R I N G I N F O R M AT I O N Mounting Brackets Catalog No. Description 1BR_ _* Mounting Brackets (set of 2) 3BR_ _* Mounting Brackets (set of 3) Mounting Shelves Catalog No. Description 1MS_ _* Mounting Shelf 2MS_ _* Mounting Shelf 3MS_ _* Mounting Shelf Length 14" (356mm) 15 3/4" (400mm) 17 3/4" (451mm) For use with CC, LM1, AA Series, ST1, and XR Series HR Series and NCB Series Height 10" (254mm) 12" (305mm) 13 1/2" (343mm) Depth 4" (102mm) 7 1/4" (184mm) 8 3/4" (222mm) *Finish Codes: GY–Grey, BK–Black, WH–White – Add suffix to catalog number when ordering (eg. 1MSGY) MOUNTING BRACKETS, MOUNTING SHELVES DESCRIPTION Recessing Kits • Recessing Kits allow fully recessed or semi-recessed installation of P4C Series Emergency Unit and R4C Series Remote. No electrical components • 20 gauge steel mounting box • Two piece adjustable bar hangers span up to 24" O R D E R I N G I N F O R M AT I O N Recessing Kits for P4C Series Catalog Number Description FRK1 Fully Recessing Kit USF1 Semi-Recessing Kit For use with P4C Series Emergency Unit, R4C Series Remote P4C Series Emergency Unit, R4C Series Remote RECESSING KITS TAMPERPROOF SCREWS & SCREWDRIVER BITS 86 COOPER LIGHTING DESCRIPTION O R D E R I N G I N F O R M AT I O N Tamperproof Screws & Screwdriver Bits • Tamperproof Screws and Screwdriver Bit for use in Steel Exits • Restricts access to internal exit or emergency lighting unit compartments • Ideally suited for use in schools, hotels, public places of assembly, etc • Increases the likelihood that the product will be functional in an emergency situation Tamperproof Screws & Screwdriver Bits Catalog No. Description TPK1CP Four #6 Centerpin Torx Zinc Plated Pan Head Sheet Metal Screws 0590A638SP One #6 Centerpin Torx Screwdriver Bit 059012SP 0590A639SP One #8 Centerpin Torx Screwdriver Bit One #8 Heavy Duty Centerpin Torx VRSD VRSPD One #8 Centerpin Torx Screwdriver One #6 Spanner Screwdriver For use with R/G/CX/OF/EP/EPH/UN/UNH/PLX Series Steel Exits, XR, AA, HR and NCB Series R/G/CX/OF/EP/EPH/UN/UNH/PLX Series Steel Exits, XR, AA, HR and NCB Series VP Series Exits TPX Series Exits Screwdriver Bit CAR, CAX, CCX, UX, UEL Series “STL” StairLite DIMENSIONS DESCRIPTION 15 1/4” [389mm] 6 3/16” [157mm] 6 11/16” [169mm] Laser Test Self-Diagnostics The self-diagnostic unit will automatically perform the tests required by the NFPA 101 Life Safety Code. The system indicates the status of the unit at all times using an LED indicator that is located near the test switch. The Sure-Lites UEL NEMA 4X Emergency Light is designed for those emergency lighting applications where ruggedness and dependability are a must. Designed for the most severe environments, the UEL Emergency Light will provide maximum performance against rain, moisture, cold, corrosives and dust. The UEL’s standard features include a die cast housing, nickel cadmium battery, self-diagnostics, photocell LASER test and MR16 lamps. In addition, an injection molded, polycarbonate shield provides protection against moisture, rain, and vandalism. (4) Torx head tamperproof screws with center-pin reject provide additional vandal-proof security. The unique design and features make the UEL Emergency Light compatible in food processing facilities, outdoor parking garages, walk-in freezers and other indoor/ outdoor severe environments. CHICAGO CODE SURE-LITES® UEL SERIES Ultimate Emergency Light CHICAGO CODE EMERGENCY LIGHTING > NEMA 4X, UL50 Listed > Dual-voltage input 120/277VAC, 60Hz, Isolation Transformer > Die cast aluminum housing with powder coat finish > (2) Adjustable MR16 lamps Verify proper operation of the transfer circuit and emergency lamps with a convenient laser pointer (sold as an accessory). SPLASH ZONE > Nickel Cadmium Battery > Fully recharged in 24 hours > Vandal Proof E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Lamp Information Model DC Voltage 1 1/2 Hours Type Wattage Number Spacing1 UEL1SD 12 24 MR16 12 29-141 50.0' > UV stable, glass-clear polycarbonate, vandal resistant shield (.150” thick) with Torx head tamperproof screws, stainless steel O R D E R I N G I N F O R M AT I O N > T1 Haz Lamp Rating SAMPLE NUMBER: UEL1SDC > Watchguard EMS Self-Diagnostic System UEL1 Family UEL1=Nema 4X Emergency Light SD Housing Finishes Blank=Silver BK=Black WH=White C C=City of Chicago Approved SD=Self Diagnostics (Standard) Options Accessories (order separately) A=Ammeter V=Voltmeter LASER=Key Chain, Red Laser Pointer (activation tested at 30 feet) TDM=Time Delay Monitor 0590-12SP=#8 Centerpin Torx Screwdriver Bit UXPKA=Pendant Kit Adapter (fitting adapts to 1/2" NPT threaded pendant) Energy Data Model No. UEL1SD Input Current (Max.): 120V 277V .09A .03A > Photocell Test Switch (requires accessory LASER for activation) > UL 924 Outdoor Wet Location Listed (suitable for wet and damp locations) > NSF, National Sanitation Foundation/Splash Zone (for Food Processing) > IP66, Ingress Protection from IEC (International Electrical Commission) > Cleanroom Class 10,000 > Patent Pending 1The "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 feet ceiling with a 6 feet wide walkway and 3 feet path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance. > City of Chicago approved COOPER LIGHTING 87 CHICAGO CODE SURE-LITES® DESCRIPTION CHEL SERIES Die Cast Aluminum DIMENSIONS The Sure-Lites CHEL Emergency Light provides a distinct solution to any emergency lighting application. Constructed of die cast aluminum, the CHEL presents not only a unique shape and design but also provides dependable strength and durability. The two, fully adjustable, high efficiency 12W MR16 lamps provide maximum path of egress performance. The standard Watchguard EMS self-diagnostic system meets NFPA 101 testing requirements providing assurance that the unit is working properly at all times. The SureLites LASER test feature allows remote, 30 second confidence testing of the emergency light upon demand. CHICAGO CODE EMERGENCY LIGHTING Self-Diagnostics The self-diagnostic unit will automatically perform the tests required by the NFPA 101 Life Safety Code. The system indicates the status of the unit at all times using an LED indicator that is located near the test switch. > Dual Voltage input, 120/277 VAC, 60 Hz > Die cast aluminum housing with powder coat finish Verify proper operation of the transfer circuit and emergency lamps with a convenient laser pointer (sold as an accessory). > Two 6V 12W MR16 lamps > Sealed Lead Calcium Battery > Watchguard EMS Self-Diagnostic System > Photocell Test Switch (requires accessory LASER for activation) > UL924 Listed, Damp location listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes > City of Chicago Approved E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Model CHEL1SD DC Voltage 6 Lamp Information 1 1/2 Hours Type Wattage Number Spacing1 24 MR16 12 29-140 50' O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: 6CHEL1SD CHEL1 Family CHEL1=Architectural Emergency Light 1The SD Housing Finishes Blank=Silver BK=Black WH=White SD=Self Diagnostics (Standard) Options Accessories (order separately) TDM=Time Delay Monitor LASER=Key Chain, Red Laser Pointer (activation tested at 30 feet) "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.5. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance. 88 COOPER LIGHTING DIMENSIONS DESCRIPTION The XR Series is an efficient, rugged, commercial grade emergency light. Most units have the extra capacity to power remote heads for added application flexibility. 11 1/4” [286mm] 2 1/4” [57mm] 4 1/2” [114mm] 2 1/4” [57mm] 12 1/4” [311mm] CHICAGO CODE SURE-LITES® XR6C XR1624C XR16C 6 1/8” [156mm] Figure 1 14 1/2” [368mm] 1 7/8” [48mm] XR7C XR9C XR20C XR21C XR12206C XR12208C 7 3/4” [197mm] 6 1/8” [156mm] 12 1/4” [311mm] 2 1/2” [64mm] Figure 2 XR SERIES E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Model Type DC Voltage XR6C XR7C XR9C* XR1624C XR16C XR20C XR21C XR12206C XR12208C SLC SLC SLC SNC SNC SNC SNC SLC SLC 6 6 6 6 6 12 12 12 12 Lamp Information 1 1/2 Hours Lamp Watts Remote Watts 27 36 54 24 50 30 50 36 54 24 24 24 24 24 24 24 24 24 Figure 3 12 30 0 26 6 26 12 30 1 2 2 1 1 2 2 2 2 Type Wattage Number 12 12 12 12 12 12 12 12 12 29-66 29-66 29-66 29-66 29-66 29-45 29-45 29-45 29-45 Halogen Halogen Halogen Halogen Halogen Halogen Halogen Halogen Halogen Steel CHICAGO CODE EMERGENCY LIGHTING > Dual-voltage input 120/277VAC, 60Hz > 22 gauge die formed steel *XR9C is UL Listed for 4 hours with 24 watt lamp load only – No remote load SLC=Sealed Lead Calcium SNC=Sealed Nickel Cadmium > White finish > Two fully adjustable metal heads with die cast swivel top mounted O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: XR6C > Sealed Lead Calcium or Premium Nickel Cadmium batteries Model Number XR6C XR1624C XR16C XR7C XR9C XR20C XR21C XR12206C XR12208C Options (add as suffix) Alternate Lamps1 A=Ammeter2 SD=Self Diagnostics3 TDM=Time Delay Monitor V=Voltmeter2 Other Options1 > Knockout, conduit or cord set A c c e s s o ri e s (order separately) 1BRWH=Mounting Brackets (2) - White 1MSWH=Mounting Shelf - White > Universal J-box mounting pattern, keyhole slots VK1=Voltmeter WG1=Wire Guard > Remote capability E N E R G Y D ATA Model No. Input Current (Max.): XR6C 120V= .21A 277V= .10A XR20C 120V= .08A XR7C 120V= .20A 277V= .09A XR21C 120V= .11A 277V= .05A XR9C 120V= .21A 277V= .10A XR12206C 120V= .29A 277V= .13A XR1624C 120V= .08A 277V= .03A XR12208C 120V= .28A 277V= .12A XR16C 120V= .08A 277V= .04A 1Consult Cooper Lighting Representative. 2XR6C, 3XR7C, XR9C, XR16C not available with SD. Model No. Input Current (Max.): 277V= .03A > Line-latching, solid-state voltage limited charger, solid-state switching, lowvoltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed , Life Safety NFPA 101, NEC/OSHA, most state and local codes. > City of Chicago approval Number 3238 XR1624 and XR16C housings have provision for one meter only. COOPER LIGHTING 89 CHICAGO CODE SURE-LITES® DESCRIPTION The real workhorse in emergency lighting systems...these durable, reliable units are unparalleled in performance and provide freedom from maintenance. The HR Series units provide a low cost, solid-state lighting system for applications in industrial, commercial, or multi-housing environments. High and Ultra High capacity makes them ideal for installations where a large number of heads/exits will be remotely operated. DIMENSIONS HR87C HR117C HR12117C Steel High Capacity Figure 2. High Capacity Figure 1. Ultra High Capacity HR180C HR12170C HR12210C HR12360C Steel Ultra-High Capacity CHICAGO CODE EMERGENCY LIGHTING > Dual-voltage input 120/277VAC, 60Hz E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Model Type DC Voltage HR87C HR117C HR12117C HR180C HR12170C HR12210C HR12360C SLC SLC SLC SLC SLC SLC SLC 6 6 12 6 12 12 12 Lamp Information 1 1/2 Hours Lamp Watts Remote Watts 87 117 117 180 170 210 360 24 24 24 24 24 24 24 63 93 93 156 146 186 336 Figure 1 1 1 2 2 2 2 Type Halogen Halogen Halogen Halogen Halogen Halogen Halogen Wattage Number 12 12 12 12 12 12 12 29-66 29-66 29-45 29-66 29-45 29-45 29-45 *Batteries may be shipped separately. SLC=Sealed Lead Calcium O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: HR87CTDM > 18 gauge die formed steel housing and cover > White finish > Two top mounted, fully adjustable, white, metal heads with die-cast swivel standard Model Number HR87C HR117C HR12117C HR180C HR12170C HR12210C HR12360C Options (add as suffix) Alternate Lamps1 A=Ammeter V=Voltmeter TDM=Time Delay Monitor Other Option1 > Sealed lead-calcium battery > Knockout, conduit or cord set > Remote capability > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes > City of Chicago approval Number 3238 90 Energy Data Model No. HR87C HR117C HR12117C HR180C HR12170C HR12210C HR12360C 1Consult COOPER LIGHTING Input Current (Max.): 120V 277V .50A .21A .53A .22A .26A .13A .98A .43A 1.08A .45A 1.02A .47A 1.17A .54A your Cooper Lighting Representative. Accessories (order separately) VK-1 =Voltmeter 3BRWH =Mounting Brackets, White Finish 2MSWH =Mounting Shelf, White Finish (For High Capacity Fixtures) 3MSWH=Mounting Shelf, White Finish (For Ultra High Capacity Fixtures) CSK120=Cord Set 120VAC CSK277=Cord Set 277VAC VS2=Polycarbonate Vandal Shield WG7=Wire Guard, For High Capacity Fixtures WG3=Wire Guard, For Ultra High Capacity Fixtures DESCRIPTION DIMENSIONS The GC Series combines a clean, sleek, contemporary appearance with state-of-theart electronics. Specifically designed for initial and retrofit installations where a recessed unit is required to maximize aesthetics. The unit is ideal for locations with limited wall space and where panoramic positioning is necessary for the ceiling mounted lampholders to provide proper light distribution. Ideal for stores, offices, hospitals and school corridors. 6 3/4” (171mm) CHICAGO CODE SURE-LITES® GC SERIES Steel Recessed CHICAGO CODE EMERGENCY LIGHTING > Dual-voltage input 120/277VAC, 60Hz E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Model DC Voltage GC15072 1 GC15072CL GC15082 1 GC15082CL 6 6 6 6 2 Hours 24 24 48 48 Lamp Information 3 Hours 4 Hours 18 18 36 36 14 14 28 28 Type Halogen Halogen Halogen Halogen Wattage Number 12 12 12 12 29-15 29-15 29-15 29-15 > 20 gauge die-formed steel housing > White finish > Metal heads available in round or cylinder styles > Heads match housing finish O R D E R I N G I N F O R M AT I O N > Knockout, conduit or cord set SAMPLE NUMBER: GC15072V Model Number GC15072 GC15072CL1 GC15082 GC15082CL1 Options ( add as suffix) Alternate Lamps 2 A=Ammeter SD=Self Diagnostics (GC15072, GC15072CL Only) TDM=Time Delay Monitor V=Voltmeter Other Options 2 E N E R G Y D ATA Model No. GC15072, GC15072CL GC15082, GC15082CL Input Current (Max.): 120V 277V .12A .05A .12A .05A Accessories (Order Separately) VK1=Voltmeter WG12=Wire Guard > Flanged for mounting in grid type suspended ceilings > Single modular electrical connector > Line-latching, solid-state voltage limited charger, solid-state switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light > UL 924 Listed , Life Safety NFPA 101, NEC/OSHA, most state and local codes. > City of Chicago approval Number 3238 > Chicago Plenum mark (CCEA - City of Chicago Environmental Air) 1CL=Cylinder Type Heads. 2Consult your Cooper Lighting Representative. COOPER LIGHTING 91 CHICAGO CODE SURE-LITES® DESCRIPTION DIMENSIONS An attractive, compact emergency lighting unit, the ST1 is a packaged in a flame-resistant metal housing. It is ideal for providing emergency lighting in commercial and institutional environments where appearance and ease of installation are critical. ST1 SERIES Steel CHICAGO CODE EMERGENCY LIGHTING > Dual-voltage input 120/277VAC, 60Hz > 18 gauge die formed steel housing E L E C T R I C A L R AT I N G S Rated Wattage to 87 1/2% of Rated D.C. Voltage Model ST1 DC Voltage 1 1/2 Hours 6 27 2 Hours 24 > Two side mounted fully adjustable heads, glare free lens > White finish > Knockout, conduit or cord Set O R D E R I N G I N F O R M AT I O N > Universal J-box mounting pattern, keyhole slots > Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light > UL 924 Listed , Life Safety NFPA 101, NEC/OSHA, most state and local codes. > City of Chicago approval Number 0590E 92 COOPER LIGHTING SAMPLE NUMBER: ST1 Model Number ST1 Accessories (Order Separately) 1BRWH=Mounting Brackets (2) - White 1MSWH=Mounting Shelf - White VK1=Voltmeter WG9=Wire Guard E N E R G Y D ATA Model No. ST1 Input Current (Max.): 120V 277V .12A 05A Lamp Information Type Wattage Tungsten Halogen 12 Number 29-66 DIMENSIONS DESCRIPTION Model Dimensions A 9.4” 9.4” 9.4” 13.3” 9.4” 9.4” 16.3” FBP140X FBP240U FBP240M FBP240H FBP240C FBP240D FBP3500 B 2.4” 2.4” 2.4” 2.4” 2.4” 2.4” 5.5” C 1.5” 1.5” 1.5” 1.5” 1.5” (Flex=28”L) 1.5” (Flex=28”L) 1.7” (Flex=28”L) When AC power fails, the Sure-Lites FBP Emergency Battery Pack automatically switches on. It maintains illumination of one or two lamps for a minimum of 90 minutes. UL Listed for field retrofit installation. CHICAGO CODE SURE-LITES® FBP SERIES Fluorescent B a tte r y Pa ck E L E C T R I C A L R AT I N G S A N D O R D E R I N G I N F O R M AT I O N Model FBP140X FBP240U FBP240M FBP240H Lamp Type 20W-40W, 2'-4', T8-T12 U-shaped, circleline, 2D, energy saving, rapid start (4-pin, 2G11) long compact fluorescent 17W-215W, 2'-8', T8-T12 HO, VHO, U-shaped, circleline, 2D, energy saving, rapid start (4-pin, 2G11) long compact fluorescent 17W-215W, 2’-8’, T8-T12 HO, VHO, U-shaped, circleline, 2D, energy saving, rapid start (4 pin, 2G11) long compact fluorescent 17W-215W, 2'-8', T8-T12 HO, VHO, U-shaped, circleline, energy saving, rapid start (4-pin, 2G11 or G24q) long compact fluorescent CHICAGO CODE Number of Lamps Operated in Emergency Mode One Initial Lumens 350-450 One 600-700 > Dual-voltage input 120/277VAC, 60Hz One–20W to 215W (2'-8') One–20W to 39W long compact fluorescent One or Two–20W to 40W (2'-4') One or Two - 17W to 24W One or Two - 32W to 40W (2'-4') One - 40W to 215W (5'-8') One or Two -18W to 39W long compact fluorescent One or Two - 18W to 28W quad compact fluorescent One or Two–6W to 28W tubular One or Two–13W to 32W or One–42W 4-pin compact fluorescent 600-700 > Compatible with many different lamp types 1100-1400 (700-1000 for long compact fluorescent) > Sealed nickel cadmium batteries 300-750 > Solid-State charger, overload/short-circuit protection, test switch/ power indicator light FBP240C 6W-28W tubular without integral starter, 13W-42W 4-pin twin, quad, or triple twin-tube compact fluorescent without integral starters FBP240D 18W-26W quad tube with integral starter in two pin base One–18W to 26W compact fluorescent 300-650 FBP3500 17W-215W, 2'-8', T-8-T12 HO, VHO, U-shaped circleline, energy saving and (4-pin, 2G11, G24Q, or GX240) twin, quad and triple twin-tube compacts One or Two-17W to 40W (2"-4") One-40W to 215W (5'-8') One or Two-18W to 49W long compact fluorescent One-40W to 55W long compact fluorescent One or Two-18W to 42W 4-pin compact fluorescent 1450-3500 O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: FBP140X FBP140X FBP240U FBP240M FBP240H FBP240C FBP240D FBP3500 Accessories (Order separately) FBP1WBC=Wire Bundle Cover for external mount applications (2 required) EMERGENCY LIGHTING > Can be installed inside or on top of a fixture > May be used with switched or unswitched fixtures > Compatible with many ballast types including standard, rapid-start, slimline, instant-start, energy-saving, dimming and electronic AC ballasts consult your Cooper Lighting Representative regarding specific applications > UL 924 Listed, UL Listed for Retrofit/ Field Installation, Life Safety NFPA 101, NEC/OSHA, most state and local codes > Chicago approved Energy Data Model No. FBP140X FBP240U FBP240M FBP240H FBP240C FBP240D FBP3500 Input Power 120V 4.5W 5.3W 5.3W 5.8W 5.3W 3.5W 8.0W COOPER LIGHTING 93 CHICAGO CODE SURE-LITES® DESCRIPTION A C L E D S E R I E S O N LY DIMENSIONS The Sure-Lites CHX Series Exits are the ideal exits for general purpose applications. An extensive range of field installed accessories, choice of faces, and the variety of possible mounting configurations permit the tailoring of this exit to almost any application. Durable steel construction, attractive styling, and high efficiency illumination make this series compatible in commercial, institutional, and multihousing applications. 6 3/4” [171mm] 4 1/2” [114mm] 2 5/16” [59mm] 7/8” [22mm] 9” [229mm] 12 1/4” [311mm] Incandescent, Fluorescent, CHX4 and CHX2 Series CHX SERIES 6 3/4” [171mm] 4 1/2” [114mm] Steel 2 5/16” [59mm] AC Only 7/8” [22mm] 4 1/2” [114mm] CHICAGO CODE EXIT LIGHTING 14 3/8” [365mm] 9” [229mm] > Dual 120/277 VAC input voltage, LED only > 120 VAC input voltage, 12 1/4” [311mm] Incandescent and Fluorescent only LED, CHX6 Series > 20 gauge steel housing, white finish > LED, Incandescent, or Fluorescent lamping > Universal pattern knockouts on rear for direct mounting to junction box > Steel canopy (where supplied) allows ceiling or end mounting > Full length 3/4" stroke arrow on directional exits > Red silkscreened lettering on white translucent, heat tempered, Impact-resistant glass lens > Other open face lenses available – consult Cooper Lighting Representative S T E E L E X I T S - A C O N LY Type Mounting No Arrow Arrow Right Arrow Left Double Arrow Wall Wall/Ceiling/End Ceiling/End CHX203 CHX203C CHX218C CHX206 CHX206C CHX221C CHX209 CHX209C CHX221C CHX212 CHX212C CHX224C Wall Wall/Ceiling/End Ceiling/End CHX403 CHX403C CHX418C CHX406 CHX406C CHX421C CHX409 CHX409C CHX421C CHX412 CHX412C CHX424C CHX Series Exits AC Only Incandescent Single Face Single Face w/Canopy Double Face w/Canopy AC Only Fluorescent Single Face Single Face w/Canopy Double Face w/Canopy AC Only LED Single Face Wall CHX603 CHX606 CHX609 CHX612 Single Face w/Canopy Double Face w/Canopy Wall/Ceiling/End Ceiling/End CHX603C CHX618C CHX606C CHX621C CHX609C CHX621C CHX612C CHX624C O R D E R I N G I N F O R M AT I O N Energy Data SAMPLE NUMBER: CHX203 > Lens installs from side of fixture for more convenient, safe maintenance > Louvered downlight standard > UL Damp Location Listed > UL 924 Listed , Life Safety NFPA 101, NEC/OSHA, > City of Chicago Approved Model Number See chart above Accessories (Order Separately) DC Socket Kit1 DCE6=Two 6V, 3.6W DC Lamps DCE12=Two 12V, 3.6W DC Lamps Canopy Kit CHX1C=White Power Pack1 CHX3500P=White 277V Conversion Canopy1 PLC277P=White Pendant Kit PK18WH=White, 18" Long 94 COOPER LIGHTING Wire Guard Choose size of wire guard desired from Accessories sheet “STAIR” Lens 004260SP=No Arrow 004261SP=Arrow Left 004262SP=Arrow Right 004263SP=Double Arrow “EXIT” Lens 004213SP=No Arrow 004214SP=Arrow Left 004215SP=Arrow Right 004216SP=Double Arrow Model No. CHX - Incandescent Input Power 120V 277V 40W 44W Model No. CHX - Fluorescent Input Power 120V 277V 14W 23W Model No. CHX - LED 120V 7W 1Incandescent Input Power 277V 7W and Fluorescent Fixtures Only. DIMENSIONS DESCRIPTION 6 3/4” [171mm] 4 1/2” [114mm] The Sure-Lites CHX Series Exits are ideal exits for general purpose applications. An extensive range of field installed accessories, choice of faces and the variety of possible mounting configurations permit the tailoring of this exit to almost any application. Durable steel construction, attractive styling and high efficiency illumination make this series compatible in commercial, institutional, and multihousing applications. 2 5/16” [59mm] 7/8” [22mm] 4 1/2” [114mm] 14 3/8” [365mm] 9” [229mm] 6 1/2” [165mm] 12 1/4” [311mm] 7 5/8” [194mm] CHICAGO CODE SURE-LITES® STEEL EXITS - SELF-POWERED Type Mounting Self Powered Incandescent Single Face Wall Single Face w/Canopy Wall/Ceiling/End Double Face w/Canopy Ceiling/End Self Powered Incandescent – High Output Single Face Wall Single Face w/Canopy Wall/Ceiling/End Double Face w/Canopy Ceiling/End Self Powered Incandescent With Double Heads Single Face Wall Single Face w/Canopy Wall/Ceiling/End Double Face w/Canopy Ceiling/End Self Powered Fluorescent Single Face Wall Single Face w/Canopy Wall/Ceiling/End Double Face w/Canopy Ceiling/End Self Powered Fluorescent – High Output Single Face Wall Single Face w/Canopy Wall/Ceiling/End Double Face w/Canopy Ceiling/End Self Powered Fluorescent With Double Heads Single Face Wall Single Face w/Canopy Wall/Ceiling/End Double Face w/Canopy Ceiling/End Self Powered LED2 Single Face Single Face w/Canopy Double Face w/Canopy Wall Wall/Ceiling/End Ceiling/End No Arrow Arrow Right Arrow Left Double Arrow CHX303 CHX303C CHX318C CHX306 CHX306C CHX321C CHX309 CHX309C CHX321C CHX312 CHX312C CHX324C CHXH303 CHXH303C CHXH318C CHXH306 CHXH306C CHXH321C CHXH309 CHXH309C CHXH321C CHXH312 CHXH312C CHXH324C CHX303DH CHX303DHC CHX318DHC CHX306DH CHX306DHC CHX321DHC CHX309DH CHX309DHC CHX321DHC CHX312DH CHX312DHC CHX324DHC CHX503 CHX503C CHX518C CHX506 CHX506C CHX521C CHX509 CHX509C CHX521C CHX512 CHX512C CHX524C CHXH503 CHXH503C CHXH518C CHXH506 CHXH506C CHXH521C CHXH509 CHXH509C CHXH521C CHXH512 CHXH512C CHXH524C CHX503DH CHX503DHC CHX518DHC CHX506DH CHX506DHC CHX521DHC CHX509DH CHX509DHC CHX521DHC CHX512DH CHX512DHC CHX524DHC CHX703 CHX703C CHX718C CHX706 CHX706C CHX721C CHX709 CHX709C CHX721C CHX712 CHX712C CHX724C WAT TA G E R AT I N G CHX Series=7.2W for 2 hrs.;CHXH Series=7.2W for 4 hrs., 32W for 1 1/2 hrs.(7.2W plus 24W Remote);CHX Double Head Series=32W for 1 1/2 hrs. SAMPLE NUMBERS: CHX Series CHX303, High Output Series CHXH303, CHX Double Head Series CHX303DH Wire Guard Choose size of wire guard desired from Accessories sheet “STAIR” Lens 004260SP=No Arrow 004261SP=Arrow Left 004262SP=Arrow Right 004263SP=Double Arrow 1Incandescent Model No. CHX - Incandescent Input Power 120V 277V 52W 52W Model No. CHX - Fluorescent Input Power 120V 277V 23W 23W Accessories (order separately) Canopy Kit CHX1C=White CHICAGO CODE EMERGENCY LIGHTING > Dual-voltage input 120/277VAC, 60Hz > 20 gauge steel housing, white finish > LED, Incandescent or Fluorescent lamping > Universal pattern knockouts on rear for direct mounting to junction box Energy Data SAMPLE NUMBER: CHX303 Pendant Kit PK18WH=White, 18" long Steel S e l f - Po w e r e d > Full length, 3/4" stroke arrow on directional exits O R D E R I N G I N F O R M AT I O N Model Number See chart above CHX/CHXH SERIES “EXIT” Lens 004213SP=No Arrow 004214SP=Arrow Left 004215SP=Arrow Right 004216SP=Double Arrow Remote Head—6V, 12W Single Head1 6T12MHWH—Two Maximum Remote Head—6V, 12W Each Double Head1 6T12DMHWH—One Maximum Input Power Model No. CHX - LED2 120V 11W 277V 12W Standby Mode (Fully Charged) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 7 Watts in the standby operating mode for incandescent and fluorescent exits. > Red silkscreened lettering on white phosphorescent, heat tempered, Impactresistant glass lens > Lens installs from side of fixture > Louvered downlight > Line-latching, solid-state voltage limited charger, solid-state switching, lowvoltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light > UL 924 Listed , Life Safety NFPA 101, NEC/OSHA > City of Chicago Approved and Fluorescent Fixtures Only. 2Chicago Approved LED Fixtures Uses Long Life NI-CD Batteries, Standard. COOPER LIGHTING 95 CHICAGO CODE SURE-LITES® DESCRIPTION DIMENSIONS The Sure-Lites EAC Exit Series combines clean, functional styling with the design benefits and durability of aluminum construction. The EAC Exit is compatible with any decor for use in ceiling, wall or end-mount applications. EAC SERIES 120V AC 277V AC E x t ru d e d A l u m i n u m AC Only CHICAGO CODE E X T R U D E D A L U M I N U M - A C O N LY EXIT LIGHTING Type Mounting No Arrow Arrow Right Arrow Left Double Arrow Wall Wall Wall/Ceiling/End Wall/Ceiling/End Ceiling/End Ceiling/End EAC10003 EAC10013 EAC20003 EAC20013 EAC300018 EAC300118 EAC10006 EAC10016 EAC20006 EAC20016 EAC300021 EAC300121 EAC10009 EAC10019 EAC20009 EAC20019 EAC300021 EAC300121 EAC100012 EAC100112 EAC200012 EAC200112 EAC300024 EAC300124 Wall Wall Wall/Ceiling/End Wall/Ceiling/End Ceiling/End Ceiling/End EAC12003 EAC12013 EAC22003 EAC22013 EAC320018 EAC320118 EAC12006 EAC12016 EAC22006 EAC22016 EAC320021 EAC320121 EAC12009 EAC12019 EAC22009 EAC22019 EAC320021 EAC320121 EAC120012 EAC120112 EAC220012 EAC220112 EAC320024 EAC320124 AC Only Incandescent > 120 VAC input voltage > Extruded aluminum housing with mitered corners and a satin anodized aluminum finish > AC incandescent: two 20W T6 1/2 intermediate base lamps Single Face (120V) Single Face (277V) Single Face w/Canopy (120V) Single Face w/Canopy (277V) Double Face w/Canopy (120V) Double Face w/Canopy (277V) AC Only Fluorescent Single Face (120V) Single Face (277V) Single Face w/Canopy (120V) Single Face w/Canopy (277V) Double Face w/Canopy (120V) Double Face w/Canopy (277V) > AC fluorescent: two 7W compact fluorescent lamps > AC lamps on separate circuits > Universal pattern knockouts on rear for direct mounting to junction box > Canopy (where supplied) allows ceiling or end mounting > Full length 3/4" stroke arrow on directional exits O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : E A C 10 0 0 3 Model Number See chart above > Red silkscreened lettering on white translucent, heat tempered, impact resistant glass lens Accessories (Order Separately) DC Socket Kit DCE6=Two 6V, 3.6W DC Lamps DCE12=Two 12V, 3.6W DC Lamps Canopy Kit QE1030SP=Aluminum Finish > Other open face lenses available – consult factory Pendant Kit H2639=Aluminum Finish, 15" Long > Lens installs from side of fixture WG10=Wire Guard WGS11=Wire Guard (for canopy mount without heads) > Louvered downlight “STAIR” Lens 004380SP = Arrow Left 004381SP = Arrow Right 004382SP = Double Arrow 004383SP = No Arrow > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA > City of Chicago Approved Energy Data Model No. Incandescent Fluorescent 96 COOPER LIGHTING Input 120V 40W 15W Power 277V 44W 23W DIMENSIONS DESCRIPTION The Sure-Lites EAC Exit Series combines clean, functional styling with the design benefits and durability of aluminum construction. The EAC Exit is compatible with any decor for use in ceiling, wall or end-mount applications. CHICAGO CODE SURE-LITES® EAC SERIES E x t ru d e d A l u m i n u m S e l f - Powe re d EXTRUDED ALUMINUM - SELF-POWERED Type CHICAGO CODE Mounting No Arrow Arrow Right Arrow Left Double Arrow Wall Wall/Ceiling/End Ceiling/End EAC40003 EAC50003 EAC600018 EAC40006 EAC50006 EAC600021 EAC40009 EAC50009 EAC600021 EAC400012 EAC500012 EAC600024 Wall Wall/Ceiling/End Ceiling/End EAC42003 EAC52003 EAC620018 EAC42006 EAC52006 EAC620021 EAC42009 EAC52009 EAC620021 EAC420012 EAC520012 EAC620024 EXIT LIGHTING Self-Powered Incandescent Single Face Single Face w/Canopy Double Face w/Canopy > Dual voltage input 120/277VAC, 60Hz Self-Powered Fluorescent Single Face Single Face w/Canopy Double Face w/Canopy WAT TA G E R AT I N G Lead Calcium Batteries: 7.2W for 2 Hrs. > Extruded aluminum housing with mitered corners and a satin anodized aluminum finish > AC incandescent: two 20W T6 1/2 intermediate base lamps > AC fluorescent: two 7W compact fluorescent lamps > DC: two 6V, 3.6W DC lamps O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: EAC40003 > Universal pattern knockouts on rear for direct mounting to junction box Model Number See chart above Accessories (order separately) Pendant Kit H2639=Aluminum Finish, 15" Long Canopy Kit QE1030SP=Aluminum Finish > Full length 3/4” stroke arrow on directional exits > Red silkscreened lettering on white phosphorescent, heat tempered, impact resistant glass lens WG10=Wire Guard WGS11=Wire Guard (for canopy mount without heads) > Lens installs from side of fixture “STAIR” Lens 004380PSSP = 004381PSSP = 004382PSSP = 004383PSSP = > Louvered downlight Arrow Left Arrow Right Double Arrow No Arrow E N E R G Y D ATA Charge Mode (Fully Discharged Battery) Sealed Lead Calcium Battery Input Power; Input Current (Max.): Power Factor: T.H.D.: 120V 277V 120V 277V 120V 277V 120V 277V Incandescent Exits - 20W Lamps 52W 52W .44A .20A — — — — Fluorescent Exits - 7W Lamps 30W 30W .44A .20A — — — — Standby Mode (Fully Charged Battery) Sealed Lead Calcium Battery Input Power consumption is reduced by approximately 7.5 Watts in the standby operating mode. > Line latching, solid-state voltage limited charger , solid-state switching, low voltage disconnect, brownout circuit, overload/ short circuit protection, test switch/power indicator light > UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, > City of Chicago Approved COOPER LIGHTING 97 LIGHTING INVERTERS SURE-LITES® DIMENSIONS DESCRIPTION MICRO INVERTER SERIES 5 0 0 VA - 2 , 0 0 0 VA HID, Fluorescent and Incandescent ON-LINE POWER I N V E R T E R SYS T E M S > Choice of 120V or 277VAC, 60Hz; other voltages available, Consult Cooper Lighting Representative. > Available from 500 to 2000 Watts (Field upgradeable) > Single Phase > Formed 16 gauge steel housing is finished in a durable powder coat finish The Sure-Lites Micro Series fast transfer inverter is a lightweight, compact unit that takes the place of larger cabinets when space is at a premium. The new modular design allows the Micro Series inverter to be configured to meet varying KW requirements from 500W to 2000W. The Micro can be configured at the factory to meet the specified job load requirements or it can be field configured at the job site when an upgrade or downgrade in load capacity is needed. In addition, the versatility of the modular design allows the individual inverter and battery cabinets to be mounted on the floor or wall, side by side, or stacked when mounting space is at a premium. The Micro Series individual inverter and individual battery cabinets are only 26"W x 10"H x 10"D providing the smallest inverter footprint in the industry. The Micro Series inverter is UL924 listed and meets NFPA 101 requirements providing the full 90 minutes of illumination for emergency egress lighting. > Small footprint, lightweight size allows for wall and floor mounting 26” [660mm] 10” [254mm] INVERTER MODULE 26” [660mm] B AT T E R Y M O D U L E 10” [254mm] 10” [254mm] S P E C I F I C AT I O N D ATA Input Voltage Input Frequency Synchronizing Slew Rate Input Protection Output Voltage Current Crest Factor Voltage THD Output Frequency Inverter Overload Output Voltage Regulation Output Protection Battery Environmental Altitude Operating Temp. Storage Temp. Relative Humidity 120 or 277 VAC, Two wire plus ground, +10/-15% 60Hz, ±3Hz 1Hz per second Input Circuit Breaker 120 or 277 VAC, Three Wire 2.8 = peak/rms <3% THD for Linear Load 60 Hz. ±0.05Hz Crystal Controlled 115% for 5 minutes ±3% for ±25% load step change (1) Output Circuit Breaker Sealed Lead Calcium VRLA 48 VDC for all models <10,000 feet without derating 20˚ to +30˚C -20° to 70°C (Electronics Only) <95% (non-condensing) > Modular design for ease of installation when space is at a premium L I F E WAY I I M I C R O S E R I E S S Y S T E M PA R T N U M B E R / R AT I N G / M E C H A N I C A L S P E C I F I C AT I O N S > Self Testing and Diagnostic with Event, Test and Alarm logs > User programmable with password protection for alarms and diagnostics > 98% efficient in standby mode - no fan needed for cooling > Battery, Input and Output Protection Circuit Breakers > Front circuit breaker and fuse access panel for easy routine maintenance > Maintenance Free Sealed Lead Calcium Batteries > UL 924 Listed, Meets NFPA 101 Requirements > City of Chicago approved 98 COOPER LIGHTING Part Number CMFT005 CMFT010 CMFT015 CMFT020 Wattage Rating 500 1000 1500 2000 VA Rating 500 1000 1500 2000 Input Voltage 120 or 277 120 or 277 120 or 277 120 or 277 Output Voltage 120 or 277 120 or 277 120 or 277 120 or 277 Battery Weight (lbs.) 107 214 321 427 System Weight (lbs.) 206 335 464 592 Cabinet H" x W" x D" 10x26x10 10x26x10 10x26x10 10x26x10 O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: CMFT CMFT Series CMFT=Micro Inverter VA Rating 005=500 010=1000 015=1500 020=2000 Voltage Input 120 277 Voltage Output 120 277 Options See page 102 for options Cabinet Qty 2 3 4 5 DESCRIPTION DIMENSIONS The Sure-Lites Lifeway II Single Phase inverter is an interruptible, PWM inverter type utilizing IGBT technology with 50ms transfer time. Should utility power fail, the Lifeway II Single Phase inverter takes over and provides output power to the critical load. Its sealed lead calcium batteries will power emergency lighting circuits for 90 minutes (UL 924). Other run times and voltages available. Consult Cooper Lighting Representative. A Height Width A B C 47" 30" 25" LIGHTING INVERTERS SURE-LITES® LIFEWAY II SINGLE PHASE IPS SERIES Depth 1 . 5 - 1 6 . 7 K VA Fluorescent and Incandescent C B ON-LINE POWER I N V E R T E R SYS T E M S S P E C I F I C AT I O N D ATA Input Voltage Input Frequency Input Protection Input Harmonic Distortion Input Power Factor Output Voltage Static Voltage Dynamic Voltage Output Harmonic Distortion Output Frequency Load Power Factor Inverter Overload Output Protection Battery Environmental Altitude Operating Temp. Storage Temp. Humidity 120 or 277VAC 1-phase 2 wire +10%-15%. Contact factory for all other voltages. 60Hz, ±3%, 50Hz available upon request Input Circuit Breaker <10% 0.5 lag/lead 120 or 277VAC 1-phase 2 wire. Contact factory for all other voltages. Load current change ±2%, battery discharge ±12.5% ±2% for ±25% load step change, ±3% for a 50% load step change, recovery within 3 cycles <3% THD for linear load 60 Hz. ±0.05Hz during emergency mode 0.5 lag to 0.5 lead 125% for 5 minutes Optional Distribution Circuit Breakers 10 Year Valve-regulated Sealed Lead Calcium (standard) > Input 120 or 277VAC 1 phase 2 wire <10,000 feet without derating System operates safely from 0° to 40°C (32° to 104°F) up to 95% humidity. UL rating, 20° to 30°C (68° to 86°F), includes battery performance wich can be affected by temperature. Contact factory for details. -20° to 70°C (Electronics Only) <95% (non-condensing) > User programmable with password protection > Custom voltages available > Electronic and magnetic ballast compatible > Generator compatibility > Forced air cooling only during emergency operation, no filters required > 90 minute runtime standard; other runtimes available upon request > 98% efficient PWM/IGBT technology with microprocessor control > Self-Testing and SelfDiagnostic with Event, Test and Alarm Logs > RS232 communications port > UL 924 listed L I F E WAY I I S I N G L E P H A S E I P S S Y S T E M PA R T N U M B E R / R AT I N G / M E C H A N I C A L S P E C I F I C AT I O N S Part Number IC1 IC2 IC3 IC4 IC5 IC6 IC7 IC8 IC9 IC10 Pwr Rtg Pwr Rtg Effic. Audible kVA kW @ full load Noise % db@1m 1.5 1.5 98 45 2.25 2.25 98 45 3.0 3.0 98 45 3.75 3.75 98 45 5.0 5.0 98 45 6.0 6.0 98 45 8.0 8.0 98 45 10.0 10.0 98 45 12.5 12.5 98 45 16.7 16.7 98 45 Heat Loss BTU 75 100 160 200 245 300 400 500 660 840 UPS Cabinet Dimensions Width Height Depth in/cm in/cm in/cm 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 UPS Weight lb/kg 250/114 265/121 295/134 305/139 315/143 350/159 375/171 435/198 465/211 530/241 Battery Voltage VDC 48 72 96 120 144 180 240 144 180 240 Battery Battery Current Run Amperes Minutes 39 90 38 90 38 90 37 90 40 90 40 90 39 90 82 90 82 90 80 90 Battery Cabinet Dimensions Width Height Depth in/cm in/cm in/cm na2 na2 na2 na2 na2 na2 na2 na2 na2 na2 na2 na2 na2 na2 na2 30/77 30/77 30/77 30/77 30/77 47/120 47/120 47/120 47/120 47/120 25/64 25/64 25/64 25/64 25/64 No. of Total Total Battery No. of System Cabinets Cabinets Weight (lb/ na2 1 546/249 na2 1 709/323 na2 1 887/403 na2 1 1045/475 na2 1 1203/546 1 2 1670/759 1 2 2087/949 2 3 2631/1195 2 3 3105/1409 2 3 3954/1795 O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : I C 3 1 2 01 2 0 IC Series IC=Single Phase IPS KVA Rating 1=1.5 2=2.25 3=3.0 4=3.75 5=5.0 6=6.0 7=8.0 8=10.0 9=12.5 10=16.7 Voltage Input 120 277 Voltage Output 120 277 Options See page 102 for options COOPER LIGHTING 99 LIGHTING INVERTERS SURE-LITES® DESCRIPTION DIMENSIONS The Sure-Lites Lifeway II C Series is a single phase inverter that provides uninterrupted power. This pulse width modulated inverter utilizes IGBT technology and has a 2 millisecond transfer time. The unit’s operating efficiency is 98%, well above a typical fast transfer inverter. The C Series inverter is UL 924 Listed and meets NFPA 101 requirements by providing 90 minutes of illumination for emergency egress lighting. Other run times and voltages are available. Please consult your Cooper Lighting Representative. LIFEWAY II SINGLE PHASE C SERIES 1 . 5 - 1 6 . 7 K VA HID, Fluorescent and Incandescent A Height Width A B Depth C 47" 30" 25" B ON-LINE POWER I N V E R T E R SYS T E M S C S P E C I F I C AT I O N D ATA > Input 120 or 277VAC 1 phase 2 wire > Custom voltages available > Electronic and magnetic ballast compatible > Generator compatibility > Forced air cooling only during emergency operation, no filters required > 90 minute runtime standard; other runtimes available upon request > 98% efficient PWM/IGBT technology with microprocessor control > User programmable with password protection > Self-Testing and SelfDiagnostic with Event, Test and Alarm Logs > RS232 communications port Input Voltage Input Frequency Input Protection Input Harmonic Distortion Input Power Factor Output Voltage Static Voltage Dynamic Voltage Output Harmonic Distortion Output Frequency Load Power Factor Inverter Overload Output Protection Battery Environmental Altitude Operating Temp. Storage Temp. Humidity 120 or 277VAC 1-phase 2 wire +10%-15%. Contact factory for all other voltages. 60Hz, ±3% Input Circuit Breaker <10% 0.5 lag/lead 120 or 277VAC 1-phase 2 wire. Contact factory for all other voltages. Load current change ±2%, battery discharge ±12.5% ±2% for ±25% load step change, ±3% for a 50% load step change, recovery within 3 cycles <3% THD for linear load 60 Hz. ±0.05Hz during emergency mode 0.5 lag to 0.5 lead 125% for 5 minutes Optional Distribution Circuit Breakers 10 Year Valve-regulated Sealed Lead Calcium (standard) <10,000 feet without derating System operates safely from 0° to 40°C (32° to 104°F) up to 95% humidity. UL rating, 20° to 30°C (68° to 86°F), includes battery performance wich can be affected by temperature. Contact factory for details. -20° to 70°C (Electronics Only) <95% (non-condensing) > UL 924 listed L I F E WAY I I S I N G L E P H A S E C S Y S T E M PA R T N U M B E R / R AT I N G / M E C H A N I C A L S P E C I F I C AT I O N S Part Number ISC015 ISC022 ISC030 ISC037 ISC048 ISC060 ISC080 ISC100 ISC125 ISC167 Pwr Rtg Pwr Rtg Effic. Audible kVA kW @ full load Noise % db@1m 1.5 1.5 98 45 2.25 2.25 98 45 3.0 3.0 98 45 3.75 3.75 98 45 4.8 4.8 98 45 6.0 6.0 98 45 8.0 8.0 98 45 10.0 10.0 98 45 12.5 12.5 98 45 16.7 16.7 98 45 Heat Loss BTU 75 100 160 200 245 300 400 500 660 840 UPS Cabinet Dimensions Width Height Depth in/cm in/cm in/cm 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 UPS Weight lb/kg 250/114 265/121 295/134 305/139 315/143 350/159 375/171 435/198 465/211 530/241 Battery Voltage VDC 48 72 96 120 144 180 240 144 180 240 Battery Battery Current Run Amperes Minutes 39 90 38 90 38 90 37 90 40 90 40 90 39 90 82 90 82 90 80 90 Battery Cabinet Dimensions Width Height Depth in/cm in/cm in/cm 2 2 na na na2 2 2 na na na2 na2 na2 na2 na2 na2 na2 na2 na2 na2 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : I S C 0 3 7 1 2 01 2 0 ISC Series ISC=Single Phase C 100 COOPER LIGHTING KVA Rating 015=1.5 022=2.25 030=3.0 037=3.75 048=4.8 060=6.0 080=8.0 100=10.0 125=12.5 167=16.7 Voltage Input 120 277 Voltage Output 120 277 Options See page 102 for options No. of Total Total Battery No. of System Cabinets Cabinets Weight (lb/kg) na2 1 546/249 na2 1 709/323 2 na 1 887/403 2 na 1 1045/475 na2 1 1203/546 1 2 1670/759 1 2 2087/949 2 3 2631/1195 2 3 3105/1409 2 3 3954/1795 DESCRIPTION DIMENSIONS The Sure-Lites Lifeway II Three Phase represents the highest performance in uninterruptible technology while the transistorized inverter is providing power protection. Ready for virtually any emergency with this stand by power system. This pulse width modulated inverter has 2 millisecond transfer time. The AC in to AC out operating efficiency is typically 98%, well above a typical fast transfer inverter. The internal construction of each cabinet consists of an AC to DC battery charger, DC to AC inverter. A C B Height Models Width Depth A B C C3FT-004 thru 016 47" 30" 25" C3FT-024 thru 050 72" 44" 31" C3FT024 thru 050* 72” 48” 31” Output Harmonic Distortion Output Frequency Load Power Factor Inverter Overload Output Protection Battery Environmental Altitude Operating Temp. Storage Temp. Humidity LIFEWAY II THREE PHASE SERIES 4 . 8 - 5 0 k VA HID, Fluorescent and Incandescent ON-LINE POWER I N V E R T E R SYS T E M S S P E C I F I C AT I O N D ATA Input Voltage Input Frequency Input Protection Input Harmonic Distortion Input Power Factor Output Voltage Static Voltage Dynamic Voltage LIGHTING INVERTERS SURE-LITES® 120/208 or 277/480VAC 3-phase 4 wire +1%-15% (Wye configuration) 60Hz, ±3%, 50Hz available upon request Input Circuit Breaker <10% .5 lag/lead 120/208 or 277/480VAC 3-phase 4 wire (Wye or Delta configuration) Load current change ±4%, battery discharge ±4% ±3% for ±25% load step change, ±6% for a 50% load step change, recovery within 3 cycles <3% THD for linear load 60 Hz. ±0.05Hz during emergency mode .5 lag to .5 lead 115% for 5 minutes Output Circuit Breaker (Optional) 10 Year Valve Regulated Sealed Lead Calcium > Choice of 120/208 VAC or 277/480 VAC, 60 Hz; other voltages available, consult Cooper Lighting Representative > Three Phase, WYE or DELTA configurations > 98% efficiency > Formed steel cabinet and doors are finished in a durable powder coat > Acoustically Quiet > PWM/GBT Technology > Sine wave output > 80db transverse mode noise attenuation > 120db common mode noise attenuation <10,000 feet without derating 20˚ to +30˚C -20° to 70°C (Electronics Only) <95% (non-condensing) > Battery circuit breaker on 24 kVA and up > RS-232 Communication > UL 924 Listed L I F E WAY I I T H R E E P H A S E S Y S T E M PA R T N U M B E R / R AT I N G / M E C H A N I C A L S P E C I F I C AT I O N S Part Number C3FT004 C3FT006 C3FT008 C3FT010 C3FT012 C3FT016 C3FT024 C3FT033 C3FT040 C3FT050 Pwr Rtg Pwr Rtg Effic. Audible kVA kW @ full load Noise % db @/m 4.8 4.8 97 45 6.0 6.0 97 45 8.0 8.0 97 45 10.0 10.0 97 45 12.5 12.5 97 45 16.7 16.7 97 45 24.0 24.0 97 45 33.0 33.0 97 45 40.0 40.0 97 45 50.0 50.0 97 45 Heat Loss BTU 326 408 544 680 850 1136 1632 2244 2720 3400 UPS Cabinet Dimensions Width Height Depth in/cm in/cm in/cm 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 44/112 72/183 31/79 44/112 72/183 31/79 44/112 72/183 31/79 44/112 72/183 31/79 UPS Weight lb/kg 535/243 535/243 535/243 639/290 639/290 639/290 1250/567 1250/567 1450/658 1450/658 Battery Voltage VDC 144 180 240 144 180 240 240 240 240 240 Battery Battery Current Run Amperes Minutes 39 90 39 90 39 90 81 90 81 90 81 90 117 90 160 90 194 90 243 90 Battery Cabinet Dimensions Width Height Depth in/cm in/cm in/cm 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 30/77 47/120 25/64 48/122 72/183 31/79 48/122 72/183 31/79 48/122 72/183 31/79 48/122 72/183 31/79 No. of Total Total Battery No. of System Cabinets Cabinets Weight (lb/kg) 1 2 1633/741 1 2 1855/842 1 2 2247/1020 2 3 2835/1286 2 3 3279/1488 2 3 4063/1843 1 2 6390/2899 2 3 8630/3915 2 3 10150/4604 2 3 11980/5434 O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : C 3 F T 0 0 4 1 2 01 2 0 C3FT Series C3FT=Three Phase KVA Rating 004=4.8 006=6.0 008=8.0 010=10.0 012=12.5 016=16.7 024=24.0 033=33.0 040=40.0 050=50.0 Voltage Input 120=120/208 277=277/480 Voltage Output 120=120/208 277=277/480 Options See page 102 for options * Battery Cabinets COOPER LIGHTING 101 LIGHTING INVERTERS SURE-LITES® INVERTERS - FACTORY OPTIONS Output Circuit Breakers W X YY ZZ W = Output - B = Normally On YY = Amp Rating (10, 20) N = Normally Off A = 120 Volt X = Pole - B = 208 Volt ZZ = Qty 01-12 C = 240 Volt Micro Inverter = 3 max. without trip alarm 1 with trip alarm D = 277 Volt Micro Inverter Series-CMFT IPS Series - IC C Series - ISC Three Phase Series - C3FT 102 COOPER LIGHTING T Circuit Breaker Trip Alarm R RS-232 Diagnostic Interface (DB9) S Summary Dry Contacts (Form “C”) N Normally Off Output A Remote Summary Alarm M Remote Meter Panel A Auto Dialer/Pager C Normally Off Dry Contact (Inverter On) D Dimmer Bypass Relay FAX Fax/Modem (utility, inverter & output failure notification) F Battery Charger Upgrade (12 Hour Recharge) G 20 Year Premium Sealed Lead Calcium Battery M Maintenance Bypass Switch (MB4B) (External or Internal) R Remote Meter Panel RSAP Remote Summary Alarm Panel S Summary Dry Contacts (Form “C”) T Output Circuit Breaker Trip Alarm V Variable Time Delay Circuit Z Zone Monitoring (16 amps Maximum) A Auto Dialer/Pager F Battery Charger Upgrade (12 Hour Recharge) FAX Fax/Modem (utility, inverter & output failure notification) G 20 Year Premium Sealed Lead Calcium Battery M Maintenance Bypass Switch (MB4B) (External or Internal) N Normally-Off Output Circuit RMP Remote Meter Panel RSAP Remote Summary Alarm Panel S Summary Dry Contacts (Form “C”) T Output Circuit Breaker Trip Alarm A Auto Dialer/Pager F Battery Charger Upgrade (12 Hour Recharge) FAX Fax/Modem (utility, inverter & output failure notification) G 20 Year Premium Sealed Lead Calcium Battery N1 Normally-Off Output Circuit, single phase N3 Normally-Off Output Circuit, three phase RMP Remote Meter Panel RSAP Remote Summary Alarm Panel S Summary Dry Contacts (Form “C”) T Output Circuit Breaker Trip Alarm - output trip alarm is not available on 24k-50k systems NI-CAD Nickel-Cadmium Battery * Consult factory for additional options and available accessories. REFERENCE-FACTORY OPTIONS EXIT LIGHTING OPTIONS S P E C I F I C AT I O N F E AT U R E S – P O LY C A R B O N A T E L E N S S P E C I F I C AT I O N F E AT U R E S – F L A S H E R Impact-resistant lens provides high degree of protection from breakage. Flashes the DC lamps of exits in the emergency mode. S P E C I F I C AT I O N F E AT U R E S – F L A S H E R / B U Z Z E R S P E C I F I C AT I O N F E AT U R E S – M E T A L H E A D S The metal housing is made of corrosion resistant, 22 gauge spun aluminum with a baked acrylic enamel finish to match fixture color. Die cast aluminum swivel assembly has 80° aiming adjustment from vertical. Flashes the DC lamps of exits in emergency mode in combination with an audible signal. Factory Options EMERGENCY LIGHTING OPTIONS REFERENCE > SURE-LITES® S P E C I F I C AT I O N F E AT U R E S – T A M P E R P R O O F S C R E W S #8-32 Button Head Stainless Steel Screws Centerpin Torx tamper resistant type S P E C I F I C AT I O N F E AT U R E S – A M M E T E R Qty. 4 per fixture Ammeter provides an easily interpreted display of the charger current level. Requires Sure-Lites No. VRSD Screwdriver S P E C I F I C AT I O N F E AT U R E S – T I M E D E L AY M O N I T O R Time delay monitor keeps the emergency lamps on after AC power has been restored for a predetermined period of time (15 minutes is standard); allows sufficient time for HID fixtures to resume normal illumination. S P E C I F I C AT I O N F E AT U R E S – V A N D A L S H I E L D A N D T A M P E R P R O O F SCREWS 1/8" thick clear polycarbonate Vandal Shield is L-shaped on single face CAX Series Exits, U-shaped on double face CAR Series Exits (4) #6-32 Flat Head Stainless Steel Screws Centerpin Torx® tamper resistant type S P E C I F I C AT I O N F E AT U R E S – T H E R M A L H E A T E R The 10 Watt Thermal Heater raises the temperature in the battery compartment of the unit when used in extreme cold conditions. The thermal heater operates at 110 VAC and is UL Listed. S P E C I F I C AT I O N F E AT U R E S – V O L T M E T E R Factory installed voltmeter provides an easily interpreted display of the battery voltage. S P E C I F I C AT I O N F E AT U R E S – D C F I R E A L A R M I N T E R F A C E F O R EXITS Fire Alarm Interface Option allows AC incandescent or LED lamps to flash in non-emergency mode and the DC lamps to flash in an emergency mode when a fire alarm signal is received by the exit fixture from a fire alarm panel. S P E C I F I C AT I O N F E AT U R E S – A C O N LY F I R E A L A R M I N T E R F A C E FOR EXITS Fire Alarm Interface Option allows AC incandescent or LED lamps to flash when a fire alarm signal is received by the exit fixture from a fire alarm panel. O R D E R I N G I N F O R M AT I O N – E M E R G E N C Y L I G H T I N G 1 UNIT OPTIONS Catalog Number Suffix Description PCL MH A TDM TH V Polycarbonate Lens Metal Heads Ammeter Time Delay Monitor Thermal Heater Voltmeter 1See O R D E R I N G I N F O R M AT I O N – E X I T L I G H T I N G O P T I O N S 1 Catalog Number Suffix Description 70 20 30 65 85 90 95 Nickel Cadmium Battery Flasher Flasher/Buzzer Tamperproof Screws Vandal Shield with Tamperproof Screws DC Fire Alarm Interface AC Only Fire Alarm Interface individual product ordering information for availability. COOPER LIGHTING 103 Self Diagnostic TECHNICAL INFORMATION > SURE-LITES® TECHNICAL INFORMATION - SELF DIAGNOSTIC DESCRIPTION ELECTRONIC TEST PERFORMANCE I N S TA L L AT I O N / O P E R AT I O N Microprocessor Based System Checks battery charger, battery voltage, lamps No special provisions required for installation A 30-second full functional test is performed every 30 days Lamp loads are automatically calibrated after battery initially reaches a full charge. A 90-minute full function/battery capacity test is performed every 6 months Version 1 System diagnoses failure to the defective component level (battery, charger PC board, lamp) and provides a visual diagnostic display through the LED indicator light CODE COMPLIANCE UL 924 Listed Life Safety NFPA 101 NEC/OSHA Most State and Local Codes Battery charge indicator differentiates high charge and standby charge mode Version 2 WatchGuard EMS SD (Electronic Monitoring System) Self Diagnostic Fa c to r y I n s t a l l e d Emergency Lighting Exit Lighting • The WatchGuard EMS self-diagnostics option from Sure-Lites sets the standard for automatic stand-alone testing of emergency lighting units and battery powered exits • The Solid-State microprocessor-based system has the ability to accurately diagnose failures to the component level plus it incorporates all of the standard electronic features that sets Sure-Lites apart from its competition • All testing required by the NFPA 101 Life Safety Code is performed automatically. WatchGuard EMS even automatically calibrates itself in the field, reducing installation labor and eliminating manual calibration errors • Ultrasensitive detection circuitry can sense lamp failure in a circuit, as well as slight variations in battery and battery charger performance • UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes 104 COOPER LIGHTING D I A G N O S T I C I N D I C AT O R S - V E R S I O N 1 INDICATOR COLOR MEANING (STEADY) GREEN FLOAT CHARGE ACTION BATTERY FULLY CHARGED (PULSE) GREEN HIGH CHARGE BATTERY BEING CHARGED AT HIGH RATE (PULSE) RED BATTERY CAPACITY FAILURE TURN OFF AC, REPLACE BATTERY - RED BATTERY OPEN TURN OFF AC, CHECK BATTERY CONNECTIONS -- RED TRANSFORMER FAILURE TURN OFF AC, REPLACE TRANSFORMER --- RED BATTERY CHARGER FAILURE TURN OFF AC, REPLACE PC BOARD (PULSE) YELLOW EMERGENCY LAMP FAILURE REPLACE EMERGENCY LAMP - YELLOW EMER. LAMP SHORT/OVERLOAD CHECK LAMP LOAD, POSSIBLE SHORT ( O N E X I T S W I T H L I G H T I N G H E A D S O N LY ) -- YELLOW EXIT LAMP FAILURE REPLACE EXIT LAMP --- YELLOW EXIT LAMP SHORT/OVERLOAD CHECK LAMP LOAD, POSSIBLE SHORT D I A G N O S T I C I N D I C AT O R S - V E R S I O N 2 INDICATOR COLOR MEANING (STEADY) RED FLOAT CHARGE ACTION BATTERY FULLY CHARGED (PULSE) RED HIGH CHARGE BATTERY BEING CHARGED AT HIGH RATE - RED BATTERY FAILURE TURN OFF AC, REPLACE BATTERY -- RED CIRCUIT FAILURE TURN OFF AC, REPLACE PC BOARD --- RED LAMP FAILURE TURN OFF AC, REPLACE PC LAMP O R D E R I N G I N F O R M AT I O N N O N - S TA N D A R D L A M P S DESCRIPTION S A M P L E N U M B E R : X R 11 3 1 3 This information is provided to help you select non-standard lamps for specific applications. In ordering Sure-Lites emergency lighting units, a standard lamp will be provided unless a particular lamp is specified by Lamp No. XR11 Model Number 3 13 No. of Lamps/ Heads TECHNICAL INFORMATION LAMP SPECIFICATIONS Make sure that the unit’s battery wattage is sufficient for powering non-standard lamps. Lamp No. 29-13 Lamp Specifications A standard XR11 is supplied with two 6 volt, 9 watt incandescent heads. To order a modified XR11 unit with three heads using 6 volt, 18 watt incandescent sealed beam lamps, the appropriate number of heads and Lamp No. must be included as an Order Suffix. Lamp N o. L010777 29-139 29-146 29-121 29-12 29-37 29-30 29-75 29-88 29-14 29-03 29-114 29-143 29-84 29-40 29-36 29-140 29-15 29-66 29-39 29-17 29-13 29-137 29-18 29-09 29-53 29-16 29-86 29-141 29-132 29-45 29-26 29-79 29-24 29-54 29-19 29-142 29-08 29-55 29-126 29-134 29-144 29-135 29-124 29-80 Z-67 29-125 29-130 29-129 Z-7 Vo l t s 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 120 120 120 120 130 145 120 Wa tt s 4.8 5 5.4 5.4 6 6 6.6 7.2 7.2 8 8 8 9 9 10 10 12 12 12 12 13 18 20 20 25 7.5 8 9 12 12 12 12 12 13 18 18 20 25 28 30 37.5 50 50 5 6 7 8 7 15 20 Ty p e Halogen Bi-Pin T21/4 MR16 Bi-Pin Base Krypton Wedge Base Incandescent Wedge Base Halogen Bi-Pin T21/4 Halogen Sealed Beam Incandescent DC Bayonet Base Incandescent Sealed Beam Incandescent Wedge Base Halogen Sealed Beam Incandescent Sealed Beam Halogen Bi-Pin T21/4 MR16 Bi-Pin Base Incandescent Wedge Base Halogen Bi-Pin T21/4 Halogen Sealed Beam MR16 Bi-Pin Base Halogen Sealed Beam Halogen Bi-Pin T21/4 Incandescent Sealed Beam Incandescent DC Bayonet Base Incandescent Sealed Beam Halogen Bi-Pin T21/4 Halogen Sealed Beam Incandescent Sealed Beam Incandescent DC Bayonet Base Halogen Sealed Beam Incandescent Wedge Base MR16 Bi-Pin Base Incandescent Wedge Base Halogen Bi-Pin T21/4 Incandescent Sealed Beam Halogen Sealed Beam Incandescent DC Bayonet Base Incandescent DC Bayonet Base Incandescent Sealed Beam MR16 Bi-Pin Base Incandescent Sealed Beam Incandescent DC Bayonet Base Incandescent Sealed Beam Halogen Sealed Beam MR16 Bi-Pin Base Halogen Sealed Beam Compact Fluorescent Twin Tube, G23 Base F6T5 Fluorescent Miniature Bi-Pin Cool White Compact Fluorescent Twin Tube, G23 Base F8T5 Fluorescent Miniature Bi-Pin Cool White Incandescent Candelabra Base, 7C7 Incandescent Candelabra Base, 15T6 Incandescent Intermediate Base T6 1/2 TECHNICAL INFORMATION > SURE-LITES® Initial Lumens 69 45 90 68 113 107 75 95 101 109 108 163 90 151 201 191 145 302 234 137 189 158 402 382 318 75 155 138 145 151 277 177 266 189 264 213 300 327 402 390 825 850 1100 250 295 390 400 46 102 92 COOPER LIGHTING 105 Wire Selection Char t TECHNICAL INFORMATION > SURE-LITES® TECHNICAL INFORMATION - WIRE SELECTION CHART W I R E S E L E C T I O N C H A R T / V O LT A G E D R O P T A B L E 6 Vo l t s M a x i m u m Vo l t a g e D r o p 5 % a s p r e s c ri b e d b y N a t i o n a l E l e c t ri c a l C o d e Wiring Length Wire Size #12 #10 #8 #6 Watts 6 89 141 225 358 8 67 106 169 268 10 53 85 135 215 12 45 71 113 179 16 33 53 84 134 18 30 47 75 120 20 27 42 68 107 24 22 35 56 89 25 21 32 54 86 28 19 30 48 77 35 15 24 39 62 44 12 19 31 49 Constant Value 534 849 1350 2148 50 11 17 27 43 75 8 11 18 29 100 6 9 14 22 150 4 6 9 15 200 250 7 11 9 150 14 23 36 57 200 10 17 27 43 250 8 14 21 34 300 Constant Value 2137 3397 5403 8590 1 2 Vo l t s M a x i m u m Vo l t a g e D r o p 5 % a s p r e s c ri b e d b y N a t i o n a l E l e c t ri c a l C o d e Wiring Run Length Wire Size #12 #10 #8 #6 Watts 8 267 425 675 1073 12 178 283 450 716 13 165 260 415 660 16 134 212 338 537 18 110 190 300 475 24 89 142 225 358 25 85 136 215 340 28 76 121 193 307 35 61 97 154 245 FORMULAS CM=22xWxL .05xE2 44 49 77 123 195 50 42 68 108 170 75 29 45 72 114 100 21 34 54 86 11 18 28 CIRCULAR MILL CHART L= CMx.05xE2 22xW The above tables show maximum wire lengths based on system voltage, wire size, and total wattage on a given wire run. To determine the maximum wire run length or total wattage on a given wire run, divide the known value into the constant value shown on the above charts for the appropriate wire size and system voltage specified. 106 13 41 65 110 165 COOPER LIGHTING CM=Wire size in circular mils W=Emergency loads in watts L=Length of circuit in feet E=Line voltage .22=Formula Constant .05=Factor for maximum allowable voltage drop Example: Four 9W remote heads (36W total) are to be operated on a 12V system using a single #10 wire run. The maximum wire run length is: Constant Value = 3397= 94 ft. known value 36 AWG 12 10 8 6 AMP CAPACITY 20 25 30 50 Example: In the system described in the example (left), the four 9W remote heads will be uniformly spaced along the wire run. The wire run can be increased to: 94ft. x 1.6 (multiplier) = 150 ft. If loads are uniformly spaced along a given wire run (equal wattages, equal distances), the determined wire length can be increased by the following multipliers: Number of Fixtures (n) Multiplier 2 3 4 1.33 1.5 1.6 CM 6,530 10,380 16,510 26,250 5+ 2n n +1 SURE-LITES® NFPA 101 (2006) 7.8.2 Sources of Illumination. 7.8.2.1* Illumination of means of egress shall be from a source considered reliable by the authority having jurisdiction. 7.8.2.2 Battery-operated electric lights and other types of portable lamps or lanterns shall not be used for primary illumination of means of egress. Batteryoperated electric lights shall be permitted to be used as an emergency source to the extent permitted under Section 7.9. 7.9 Emergency Lighting. 7.9.1 General. 7.9.1.1* Emergency lighting facilities for means of egress shall be provided in accordance with Section 7.9 for the following: (1) Buildings or structures where required in Chapter 11 through Chapter 42 (2) Underground and limited access structures as addressed in Section 11.7 (3) High-rise buildings as required by other sections of this Code (4) Doors equipped with delayed-egress locks (5) Stair shaft and vestibule of smokeproof enclosures, for which the following also apply: (a) The stair shaft and vestibule shall be permitted to include a standby generator that is installed for the smokeproof enclosure mechanical ventilation equipment. (b) The standby generator shall be permitted to be used for the stair shaft and vestibule emergency lighting power supply. (6) New access-controlled egress doors in accordance with 7.2.1.6.2. 7.9.1.2 For the purposes of 7.9.1.1, exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of 7.9.1.1, exit discharge shall include only designated stairs, ramps, aisles, walkways, and escalators leading to a public way. 7.9.1.3 Where maintenance of illumination depends on changing from one energy source to another, a delay of not more than 10 seconds shall be permitted. 7.9.2 Performance of System. 7.9.2.1* Emergency illumination shall be provided for not less than 1 1/2 hours in the event of failure of normal lighting. Emergency lighting facilities shall be arranged to provide initial illumination that is not less than an average of 1 ft-candle (10.8 lux) and, at any point, not less than 0.1 ft-candle (1.1 lux), measured along the path of egress at floor level. Illumination levels shall be permitted to decline to not less than an average of 0.6 ft-candle (6.5 lux) and, at any point, not less than 0.06 ft-candle (.65 lux) at the end of the 1 1/2 hours. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. 7.9.2.2 New emergency power systems for emergency lighting shall be at least Type 10, Class 1.5, Level 1, in accordance with NFPA 110, Standard for Emergency and Standby Power Systems. 7.9.2.3* The emergency lighting system shall be arranged to provide the required illumination automatically in the event of any interruption of normal lighting due to any of the following: (1) Failure of a public utility or other outside electrical power supply (2) Opening of a circuit breaker or fuse (3) Manual act(s), including accidental opening of a switch controlling normal lighting facilities 7.9.2.4 Emergency generators providing power to emergency lighting systems shall be installed, tested, and maintained in accordance with NFPA 110, Standard for Emergency and Standby Power Systems. Stored electrical energy systems, where required in this Code, shall be installed and tested in accordance with NFPA 111, Standard on Stored Electrical Energy Emergency and Standby Power Systems. 7.9.2.5 Unit equipment and battery systems for emergency luminaires shall be listed to UL 924, Standard for Emergency Lighting and Power Equipment. 7.9.2.6* Existing battery-operated emergency lights shall use only reliable types of rechargeable batteries provided with suitable facilities for maintaining them in properly charged condition. Batteries used in such lights or units shall be approved for their intended use and shall comply with NFPA 70, National Electrical Code. 7.9.2.7 The emergency lighting system shall be either continuously in operation or shall be capable of repeated automatic operation without manual intervention. Life Safety Code: National Fire Protection Association 7.8 Illumination of Means of Egress. 7.8.1 General 7.8.1.1* Illumination of means of egress shall be provided in accordance with Section 7.8 for every building and structure where required in Chapter 11 through Chapter 42. For the purposes of this requirement, exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of this requirement, exit discharge shall include only designated stairs, aisles, corridors, ramps, escalators, walkways, and exit passage ways leading to a public way. 7.8.1.2 Illumination of means of egress shall be continuous during the time that the conditions of occupancy require that the means of egress be available for use, unless otherwise provided in 7.8.1.2.2. 7.8.1.2.1 Artificial lighting shall be employed at such locations and for such periods of time as are necessary to maintain the illumination to the minimum criteria values herein specified. 7.8.1.2.2 Automatic, motion sensor-type lighting switches shall be permitted within the means of egress, provided that the switch controllers are equipped for fail-safe operation, the illumination timers are set for a minimum 15-minute duration, and the motion sensor is activated by any occupant movement in the area served by the lighting units. 7.8.1.3* The floors and other walking surfaces within an exit and within the portions of the exit access and exit discharge designated in 7.8.1.1 shall be illuminated as follows: (1) During conditions of stair use, the minimum illumination for new stairs shall be at least 10 ft-candle (108 lux), measured at the walking surfaces. (2) The minimum illumination for floors and walking surfaces, other than new stairs during conditions of stair use, shall be to values of at least 1 ft-candle (10.8 lux), measured at the floor. (3) In assembly occupancies, the illumination of the floors of exit access shall be at least 0.2 ft-candle (2.2 lux) during periods of performances or projections involving directed light. (4) * The minimum illumination requirements shall not apply where operations or processes require low lighting levels. 7.8.1.4* Required illumination shall be arranged so that the failure of any single lighting unit does not result in an illumination level of less than 0.2 ft-candle (2.2 lux) in any designated area. 7.8.1.5 The equipment or units installed to meet the requirements of Section 7.10 also shall be permitted to serve the function of illumination of means of egress, provided that all requirements of Section 7.8 for such illumination are met. TECHNICAL INFORMATION > TECHNICAL INFORMATION LIFE SAFETY CODE®: NATIONAL FIRE PROTECTION ASSOC. 7.9.3 Periodic Testing of Emergency Lighting Equipment. 7.9.3.1 Required emergency lighting systems shall be tested in accordance with one of the three options offered by 7.9.3.1.1, 7.9.3.1.2, or 7.9.3.1.3. 7.9.3.1.1 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Functional testing shall be conducted at 30-day intervals for not less than 30 seconds. (2) Functional testing shall be conducted annually for not less than 1 1/2 hours if the emergency lighting system is battery powered. (3) The emergency lighting equipment shall be fully operational for the duration of the tests required by 7.9.3.1.1 (1) and 7.9.3.1.1 (2). (4) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction. 7.9.3.1.2 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall be provided. Reprinted with permission from NFPA 101®, Life Safety Code®, Copyright© 2006, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the reference subject which is represented only by the standard in its entirety. COOPER LIGHTING 107 Life Safety Code: National Fire Protection Association TECHNICAL INFORMATION > 108 SURE-LITES® TECHNICAL INFORMATION LIFE SAFETY CODE®: NATIONAL FIRE PROTECTION ASSOC. (2) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall automatically perform not less than once every 30 days a test for not less than 30 seconds and a diagnostic routine. (3) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall indicate failures by a status indicator. (4) A visual inspection shall be performed at intervals not exceeding 30 days. (5) Functional testing shall be conducted annually for not less than 1 1/2 hours. (6) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall be fully operational for the duration of the 1 1/2 hour test. (7) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction. 7.9.3.1.3 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Computer-based, self-testing/self-diagnostic battery-operated emergency lighting equipment shall be provided. (2) The emergency lighting equipment shall automatically per form not less than once every 30 days a test for not less than 30 seconds and a diagnostic routine. (3) The emergency lighting equipment shall automatically per form annually a test for not less than 11/2 hours. (4) The emergency lighting equipment shall be fully operational for the duration of the tests required by 7.9.3.1.3(2) and 7.9.3.1.3(3). (5) The computer-based system shall be capable of providing a report of the history of tests and failures at all times. 7.10 Marking of Means of Egress. 7.10.1 General. 7.10.1.1 Where Required. Means of egress shall be marked in accordance with Section 7.10 where required in Chapter 11 through Chapter 42. 7.10.1.2* Exits. Exits, other than main exterior exit doors that obviously and clearly are identifiable as exits, shall be marked by an approved sign that is readily visible from any direction of exit access. 7.10.1.3 Exit Stair Door Tactile Signage. Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT (3) Tactile signage shall comply with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities. 7.10.1.4 Existing Exemption. The requirements of 7.10.1.3 shall not apply to existing buildings, provided that the occupancy classification does not change. 7.10.1.5 Exit Access. 7.10.1.5.1 Access to exits shall be marked by approved, readily visible signs in all cases where the exit or way to reach the exit is not readily apparent to the occupants. 7.10.1.5.2* New sign placement shall be such that no point in an exit access corridor is in excess of the rated viewing distance or 100 ft (30 m), whichever is less, from the nearest sign. 7.10.1.6* Floor Proximity Exit Signs. Where floor proximity exit signs are required in Chapter 11 through Chapter 42, such signs shall be located near the floor level in addition to those signs required for doors or corridors. The signs shall be illuminated in accordance with 7.10.5. Externally illuminated signs shall be sized in accordance with 7.10.6.1. The bottom of the sign shall be not less than 6 in. (150 mm), but not more than 18 in. (455 mm), above the floor. For exit doors, the sign shall be mounted on the door or adjacent to the door, with the nearest edge of the sign within 4 in. (100 mm) of the door frame. 7.10.1.7* Floor Proximity Egress Path Marking. Where floor proximity egress path marking is required in Chapter 11 through Chapter 42, a listed and approved floor proximity egress path marking system that COOPER LIGHTING is internally illuminated shall be installed within 18 in. (455 mm) of the floor. The system shall provide a visible delineation of the path of travel along the designated exit access and shall be essentially continuous, except as interrupted by doorways, hallways, corridors, or other such architectural features. The system shall operate continuously or at any time the building fire alarm system is activated. The activation, duration, and continuity of operation of the system shall be accordance with 7.9.2. The system shall be maintained in accordance with the product manufacturing listing. 7.10.1.8* Visibility. Every sign required in Section 7.10 shall be located and of such size, distinctive color, and design that it is readily visible and shall provide contrast with decorations, interior finish, or other signs. No decorations, furnishings, or equipment that impairs visibility of a sign shall be permitted. No brightly illuminated sign (for other than exit purposes), display, or object in or near the line of vision of the required exit sign that could detract attention from the exit sign shall be permitted. 7.10.1.9 Mounting Location. The bottom of new egress markings shall be located at a vertical distance of not more than 6 ft 8 in. (2030 mm) above the top edge of the egress opening intended for designation by that marking. Egress markings shall be located at a horizontal distance of not more than the required width of the egress opening, as measured from the edge of the egress opening intended for designation by that marking to the nearest edge of the marking. 7.10.2* Directional Signs. A sign complying with 7.10.3 with a directional indicator showing the direction of travel shall be placed in every location where the direction of travel to reach the nearest exit is not apparent. 7.10.3* Sign Legend. 7.10.3.1 Signs required by 7.10.1 and 7.10.2 shall read as follows in plainly legible letters, or other appropriate wording shall be used: EXIT 7.10.3.2* Where approved by the authority having jurisdiction, pictograms shall be permitted. 7.10.4* Power Source. Where emergency lighting facilities are required by the applicable provisions of Chapter 11 through Chapter 42 for individual occupancies, the signs, other than approved selfluminous signs and listed photoluminescent signs in accordance with 7.10.7.2, shall be illuminated by the emergency lighting facilities. The level of illumination of the signs shall be in accordance with 7.10.6.3 or 7.10.7 for the required emergency lighting duration as specified in 7.9.2.1. However, the level of illumination shall be permitted to decline to 60 percent at the end of the emergency lighting duration. 7.10.5 Illumination of Signs. 7.10.5.1* General. Every sign required by 7.10.1.2, 7.10.1.5, or 7.10.8.1, other than where operations or processes require low lighting levels, shall be suitably illuminated by a reliable light source. Externally and internally illuminated signs shall be legible in both the normal and emergency lighting mode. 7.10.5.2* Continuous Illumination. 7.10.5.2.1 Every sign required to be illuminated by 7.10.6.3, 7.10.7, and 7.10.8.1 shall be continuously illuminated as required under the provisions of Section 7.8, unless otherwise provided in 7.10.5.2.2. 7.10.5.2.2* Illumination for signs shall be permitted to flash on and off upon activation of the fire alarm system. 7.10.6 Externally Illuminated Signs. 7.10.6.1* Size of Signs. 7.10.6.1.1 Externally illuminated signs required by 7.10.1 and 7.10.2, other than approved existing signs, unless otherwise provided in 7.10.6.1.2, shall read EXIT, or shall use other appropriate wording in plainly legible letters sized as follows: (1) For new signs, the letters shall be not less than 6 in. (150 mm) high, with the principal strokes of letters not less than 3/4 in. (19 mm) wide. (2) For existing signs, the required wording shall be permitted to be in plainly legible letters not less than 4 in. (100 mm) high. Reprinted with permission from NFPA 101®, Life Safety Code®, Copyright© 2006, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the reference subject which is represented only by the standard in its entirety. SURE-LITES® LIFE SAFETY CODE®: NATIONAL FIRE PROTECTION ASSOC. way of exit access and that is located or arranged so that it is likely to be mistaken for an exit shall be identified by a sign that reads as follows: NO EXIT 7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 2 in. (51 mm) high, with a stroke width of 3/8 in. (9.5 mm), and the word EXIT in letters 1 in. (25 mm) high, with the word EXIT below the word NO, unless such sign is an approved existing sign. 7.10.8.4 Elevator Signs. Elevators that are a part of a means of egress (see 7.2.13.1) shall have the following signs with a minimum letter height of 5/8 in. (16 mm) posted in every elevator lobby: (1) *Signs that indicate that the elevator can be used for egress, including any restrictions on use (2) *Signs that indicate the operational status of elevators 7.10.9 Testing and Maintenance. 7.10.9.1 Inspection. Exit signs shall be visually inspected for operation of the illumination sources at intervals not to exceed 30 days or shall be periodically monitored in accordance with 7.9.3.1.3. 7.10.9.2 Testing. Exit signs connected to or provided with a battery-operated emergency illumination source, where required in 7.10.4, shall be tested and maintained in accordance with 7.9.3. FIGURE 7.10.6.2.1 Chevron-Type Indicator. 7.10.6.2.2 The requirements of 7.10.6.2.1 shall not apply to approved existing signs. 7.10.6.3* Level of Illumination. Externally illuminated signs shall be illuminated by not less than 5 ft-candles (54 lux) at the illuminated surface and shall have a contrast ratio of not less than 0.5. Life Safety Code: National Fire Protection Association (3) The word EXIT shall be in letters of a width not less than 2 in. (51 mm), except the letter I, and the minimum spacing between letters shall be not less than 3/8 in. (9.5 mm). (4) Sign legend elements larger than the minimum established in 7.10.6.1.1(1) through 7.10.6.1.1(3) shall use letter widths, strokes, and spacing in proportion to their height. 7.10.6.1.2 The requirements of 7.10.6.1.1 shall not apply to marking required by 7.10.1.3 and 7.10.1.6. 7.10.6.2* Size and Location of Directional Indicator. 7.10.6.2.1 Directional indicators, unless otherwise provided in 7.10.6.2.2, shall comply with the following: (1) The directional indicator shall be located outside of the EXIT legend, not less than 3/8 in. (9.5 mm) from any letter. (2) The directional indicator shall be of a chevron type, as shown in Figure 7.10.6.2.1. (3) The directional indicator shall be identifiable as a directional indicator at a distance of 40 ft (12m). (4) A directional indicator larger than the minimum established for compliance with 7.10.6.2.1(3) shall be proportionately increased in height, width and stroke. (5) The directional indicator shall be located at the end of the sign for the direction indicated. TECHNICAL INFORMATION > TECHNICAL INFORMATION - 7.10.7 Internally Illuminated Signs. 7.10.7.1 Listing. Internally illuminated signs shall be listed in accordance with UL 924, Standard for Emergency Lighting and Power Equipment, unless they meet one of the following criteria: (1) They are approved existing signs. (2) They are existing signs having the required wording in legible letters not less than 4 in. (100mm) high. (3) They are signs that are in accordance with 7.10.1.3 and 7.10.1.6. 7.10.7.2* Photoluminescent Signs. The face of a photoluminescent sign shall be continually illuminated while the building is occupied. The illumination levels on the face of the photoluminescent sign shall be in accordance with its listing. The charging illumination shall be a reliable light source as determined by the authority having jurisdiction. The charging light source shall be of a type specified in the product markings. 7.10.8 Special Signs. 7.10.8.1 Sign Illumination. 7.10.8.1.1 Where required by other provisions of this Code, special signs shall be illuminated in accordance with 7.10.5, 7.10.6.3, and 7.10.7. 7.10.8.1.2 Where emergency lighting facilities are required by the applicable provisions of Chapter 12 through Chapter 42, the required illumination of special signs shall additionally be provided under emergency lighting conditions. 7.10.8.2 Characters. Special signs, where required by other provisions of this Code, shall comply with the visual character requirements of ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities. 7.10.8.3* No Exit. 7.10.8.3.1 Any door, passage, or stairway that is neither an exit nor a Reprinted with permission from NFPA 101®, Life Safety Code®, Copyright© 2006, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the reference subject which is represented only by the standard in its entirety. COOPER LIGHTING 109 INDEX SURE-LITES® NUMERICAL INDEX PRODUCT NO. PAGE NO. 059012SP 0590A638SP 0590A639SP 12T12DMHWH 12T12DWMHWH 12T12DWXX 12T12MHWH 12T12WMHWH 12T12WXX 12T12XXU 12T37DWMHWH 12T37WMHWH 12T50DMHWH 12T50DWMHWH 12T50MHWH 12T50WMHWH 12T8DWMHWH 12T8DWXX 12T8WMHWH 12T8WXX 12T8XXU 12X12DWMHWH 12X12WMHWH 12X12XXU 12X18DWMHWH 12X18WMHWH 12X25DWMHWH 12X25DWXX 12X25HZB 12X25HZP 12X25WMHWH 12X25WXX 12X25XXU 12X30DWMHWH 12X30WMHWH 12X9WHU 12XW12DWMHWH 12XW12DWXX 12XW12WMHWH 12XW12WXX 12XW9DWMHWH 12XW9DWXX 12XW9WMHWH 12XW9WXX 1BR 1MS 1RTPL 20 29-03 29-08 29-09 29-114 29-12 29-121 29-124 29-125 29-126 29-129 29-13 29-130 29-132 29-134 29-135 29-137 29-139 29-14 29-140 110 COOPER LIGHTING 86 86 86 34 34 33 34 34 33 33 34 34 34 34 34 34 34 33 34 33 33 34 34 33 34 34 34 33 37 37 34 33 33 34 34 33 34 33 34 33 34 33 34 33 86 86 85 103 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 PRODUCT NO. 29-141 29-142 29-143 29-144 29-146 29-15 29-16 29-17 29-18 29-19 29-24 29-26 29-30 29-36 29-37 29-39 29-40 29-45 29-53 29-54 29-55 29-66 29-75 29-79 29-80 29-84 29-86 29-88 2M 30 3BR 3M 65 6T10DWMHWH 6T10WMHWH 6T12DMHWH 6T12DWMHWH 6T12MHWH 6T12WMHWH 6T12XXU 6T20DWMHWH 6T20WMHWH 6T6DMHWH 6T6DWMHWH 6T6DWXX 6T6MHWH 6T6WMHWH 6T6WXX 6T6XXU 6T8DWMHWH 6T8DWXX 6T8WMHWH 6T8WXX 6T8XXU 6X12DWMHWH 6X12WMHWH 6X12XXU 6X18DWMHWH 6X18WMHWH 6X25DWMHWH 6X25WMHWH 6X25XXU 6X54XXU 6X7DWMHWH 6X7DWXX 6X7MHWH 6X7WMHWH PAGE NO. 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 86 103 86 86 103 34 34 34 34 34 34 33 34 34 34 34 33 34 34 33 33 34 33 34 33 33 34 34 33 34 34 34 34 33 33 34 33 34 34 PRODUCT NO. PAGE NO. 6X7WXX 33 6X7XXU 33 6X8DWMHWH 34 6X8WMHWH 34 6X9DWXX 33 6X9WXX 33 6X9XXU 33 6XW54DWMHWH 34 6XW54DWXX 33 6XW54WMHWH 34 6XW54WXX 33 6XW7DWMHWH 34 6XW7DWXX 33 6XW7WMHWH 34 6XW7WXX 33 6XW9DWMHWH 34 6XW9DWXX 33 6XW9WMHWH 34 6XW9WXX 33 70 103 85 103 90 103 95 103 A 103 AA1 32 AA8 32 AD277CAX 81 AD277CAXBZ 81 AD277CAXW 81 AD2C120CAX 81 AD2C1277CAX 81 AD2CUCAX 81 AEL1BKSD 8 AEL1BZSD 8 AEL1WHSD 8 AP series 64, 65 AP2SQ 63 BZ1 81 C3FT004 101 C3FT006 101 C3FT008 101 C3FT010 101 C3FT012 101 C3FT016 101 C3FT024 101 C3FT033 101 C3FT040 101 C3FT050 101 C7213EEMSL 17 CAN277ELX 81 CAN571 84 CAN578 84 CAR Series 48, 49 CAX Series 42, 43, 44, 45 CAX18PKBK 83 CAX18PKBZ 83 CAX18PKHTBK 84 CAX18PKHTBZ 84 CAX18PKHTWH 84 CAX18PKWH 83 CAX3PP 82 CAX3PPBZ 82 CAX3PPW 82 CAXSBOXBKSP 84 CAXSBOXBZSP 84 CAXSBOXWHSP 84 CC10SD 25 PRODUCT NO. CC11SD CC12SD CC2 CC2347 CC3 CC3NC CC4 CC4NC CC5 CC5NC CC6 CC7 CC7NCSD CC8 CC9SD CCX Series CCX18PKBK CCX18PKHTBK CCX18PKHTWH CCX18PKWH CCX277 CCXH SERIES CFR103 CFR116 CFR203 CFR216 CHEL Series CHEL1BKSD CHEL1SD CHEL1WHSD CHX203 CHX203C CHX206 CHX206C CHX209 CHX209C CHX212 CHX212C CHX218C CHX221C CHX224C CHX303 CHX303C CHX303DH CHX303DHC CHX306 CHX306C CHX306DH CHX306DHC CHX309 CHX309C CHX309DH CHX309DHC CHX312 CHX312C CHX312DH CHX312DHC CHX318C CHX318DHC 110 CHX321C CHX321DHC CHX324C CHX324DHC CHX403 CHX403C CHX406 CHX406C PAGE NO. 25 25 21 21 22 22 22 22 22 22 22 23 23 24 25 52, 53, 54 83 84 84 83 81 54 36 36 36 36 9, 88 9 9 9 94 94 94 94 94 94 94 94 94 94 94 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 94 94 94 94 NUMERICAL INDEX PRODUCT NO. CHX409 CHX409C CHX412 CHX412C CHX418C CHX421C CHX424C CHX503 CHX503C CHX503DH CHX503DHC CHX506 CHX506C CHX506DH CHX506DHC CHX509 CHX509C CHX509DH CHX509DHC CHX512 CHX512C CHX512DH CHX512DHC CHX518C CHX518DHC CHX521C CHX521DHC CHX524C CHX524DHC CHX603 CHX603C CHX606 CHX606C CHX609 CHX609C CHX612 CHX612C CHX618C CHX621C CHX624C CHX703 CHX703C CHX706 CHX706C CHX709 CHX709C CHX712 CHX712C CHX718C CHX721C CHX724C CHXH303 CHXH303C CHXH306 CHXH306C CHXH309 CHXH309C CHXH312 CHXH312C CHXH318C CHXH321C CHXH324C CHXH503 CHXH503C CHXH506 CHXH506C CHXH509 PAGE NO. 94 94 94 94 94 94 94 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 94 94 94 94 94 94 94 94 94 94 94 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 PRODUCT NO. CHXH509C CHXH512 CHXH512C CHXH518C CHXH521C CHXH524C CMFT005 CMFT010 CMFT015 CMFT020 CSK120 CSK277 CU1 CU1347 CU1HD CU1HD347 CU1NC CU1R CU1RB CU2 CX Series DR112 DR145 DR166 DR212 DR245 DR266 EAC100012 EAC10003 EAC10006 EAC10009 EAC100112 EAC10013 EAC10016 EAC10019 EAC120012 EAC12003 EAC12006 EAC12009 EAC120112 EAC12013 EAC12016 EAC12019 EAC200012 EAC20003 EAC20006 EAC20009 EAC200112 EAC20013 EAC20016 EAC20019 EAC220012 EAC22003 EAC22006 EAC22009 EAC220112 EAC22013 EAC22016 EAC22019 EAC300018 EAC300021 EAC300024 EAC300118 EAC300121 EAC300124 EAC320018 EAC320021 PAGE NO. 95 95 95 95 95 95 98 98 98 98 85 85 26 26 26 26 26 36 36 27 41 36 36 36 36 36 36 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 PRODUCT NO. EAC320024 EAC320118 EAC320121 EAC320124 EAC400012 EAC40003 EAC40006 EAC40009 EAC420012 EAC42003 EAC42006 EAC42009 EAC500012 EAC50003 EAC50006 EAC50009 EAC520012 EAC52003 EAC52006 EAC52009 EAC600018 EAC600021 EAC600024 EAC620018 EAC620021 EAC620024 EEX Series ELX Series EMS277 EPX5000B EPX5000P ES Series EUR Series EUS Series FBP140X FBP240C FBP240D FBP240H FBP240HSD FBP240HU FBP240M FBP240U FBP3500 FBP450LP FL1 FRK1 G2277CXBLED G2277CXLED G2CX G2CXB G2CXBLED G2CXBS G2CXLED GC15012 GC15022 GC15032 GC15042 GC15052 GC15072 GC15072CL GC15082 GC15082CL GC15122 GC15132 GC15142 GC15172 GC15182 PAGE NO. 96 96 96 96 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 55 38 85 82 82 40 57 56 76, 93 76, 93 76, 93 76, 93 76 76 76, 93 6, 93 76, 93 76 81 86 60 60 60 60 60 60 60 13 13 13 13 13 91 91 91 91 13 13 13 13 13 PRODUCT NO. GFR2703 GFR2716 H274EM HR117 HR117C HR12117 HR12117C HR12170 HR12170C HR12210 HR12210C HR12360 HR12360C HR180 HR180C HR87 HR87C HS1R HZU125425 HZX21 HZX22 HZX23 IC1 IC10 IC2 IC3 IC4 IC5 IC6 IC7 IC8 IC9 INCX Series ISC015 ISC022 ISC030 ISC037 ISC048 ISC060 ISC080 ISC100 ISC125 ISC167 L010777 LM1 LPX Series LPX(H) Series LTC1 LTC2 MH ML1 ML2 ML3 ML4NC ML5NC MML1 MML2 MR12T12 MR12T12D MR6T12 MR6T12D MRT12T12 MRT12T12D MRT12T12HAZ MRT12T12W MRT12T20 MRT12T20D INDEX SURE-LITES® PAGE NO. 36 36 18 29 90 29 90 29 90 29 90 29 90 29 90 29 90 30 69 75 75 75 99 99 99 99 99 99 99 99 99 99 58 100 100 100 100 100 100 100 100 100 100 105 31 50 51 77 78 103 11 11 11 11 11 10 10 35 35 35 35 35 35 37 37 35 35 COOPER LIGHTING 111 INDEX SURE-LITES® NUMERICAL INDEX PRODUCT NO. PAGE NO. MRT12T20HAZ MRT12T20W MRT12T50 MRT12T50D MRT12T50W MRT6T12 MRT6T12D MRT6T12HAZ MRT6T12W MRT6T5 MRT6T5D MRT6T5HAZ MRT6T5W MRT6T9 MRT6T9D MRT6T9HAZ MRT6T9W NCB110 NCB12180 NCB12225 NCB1290 NCB45 NCB9 OF2CX OF2CXB OF2CXBS P4C1 P4C2 P4C22 P4C3 P4C6 P4C7 P4C72 PCL PHL Series PK18BK PK18HTBK PK18HTWH PK18WH PLC277B PLC277P PLC2C120 PLC2C1277 PLC2CU PLX5200GB PLX5200GBS PLX5200GP PLX5200OB PLX5200OBS PLX5200OP PLX5200RB PLX5200RBS PLX5200RP PLX6200GB PLX6200GBS PLX6200GP PLX6200OB PLX6200OBS PLX6200OP PLX6200RB PLX6200RBS PLX6200RP PLX7200GB PLX7200GBS PLX7200GP PLX7200OB PLX7200OBS 112 COOPER LIGHTING 37 37 35 35 37 35 35 37 37 35 35 37 37 35 35 37 37 67 67 67 67 67 67 60 60 60 15 15 15 15 15 15 15 103 74 83 84 84 83 81 81 81 81 81 60 60 60 60 60 60 60 60 60 61 61 61 61 61 61 61 61 61 61 61 61 61 61 PRODUCT NO. PLX7200OP PLX7200RB PLX7200RBS PLX7200RP PLX7202GB PLX7202GBS PLX7202GP PLX7202OB PLX7202OBS PLX7202OP PLX7202RB PLX7202RBS PLX7202RP R2277CXBLED R2277CXLED R2CX R2CXB R2CXBLED R2CXBS R2CXLED R4C14 R4C145 RBP13 RBP13347 RBP1826 RBP1826347 RBP RBP9347 RD1 RD3 RD4 RD6 RD7 REM240 RFR130 RFR153 RG1 RG2 RKRC Series RKRI Series RLM1 RLM2 RLM3 RLM4 RLM8 RLM9 SLC1 SLC120 SLC120H SLC1H SLC2 SLC220 SLC220H SLC2H SLX Series ST1 STL STL2 TDM TH TPK1CP TPX Series TRX1 Series UEL Series UMB1 UMB14 UMB15 PAGE NO. 61 61 61 61 62 62 62 62 62 62 62 62 62 60 60 60 60 60 60 60 37 37 80 80 80 80 80 80 12 12 12 12 12 80 37 37 16 16 79 79 12 12 12 12 12 12 14 14 14 14 14 14 14 14 59 92 19 20 103 103 86 46, 47 73 66, 87 68 68 68 PRODUCT NO. UMB16 UMB17 UMB6 UMB7 UMB8 UMB9 UMX Series UN1OFB UN1OFBS UN1OFW UN1SGB UN1SGBLED UN1SGBS UN1SGW UN1SGWLED UN1SRB UN1SRBLED UN1SRBS UN1SRW UN1SRWLED UNH1OFB UNH1OFBDH UNH1OFBS UNH1OFBSDH UNH1OFW UNH1OFWDH UNH1SGB UNH1SGBDH UNH1SGBLEDL UNH1SGBS UNH1SGBSDH UNH1SGW UNH1SGWBDHL UNH1SGWBLED UNH1SGWDH UNH1SGWDHL UNH1SRB UNH1SRBDH UNH1SRBLED UNH1SRBS UNH1SRBSDH UNH1SRW UNH1SRWBDHL UNH1SRWDH UNH1SRWDHL UNH1SRWLED USF1 UX Series V VK1 VRSD VRSPD VRX Series VS1 VS1WP VS2 VS2WP WatchGuard EMS SD WG1 WG10 WG12 WG17 WG19 WG2 WG3 WG4 WG5 PAGE NO. 68 68 68 68 68 68 71 61 61 61 61 61 61 61 61 61 61 61 61 61 61 62 61 62 61 62 61 62 61 61 62 61 62 61 62 62 61 62 61 61 62 61 62 62 62 61 86 70 103 85 86 86 72 83 83 83 83 104 83 83 83 83 83 83 83 83 83 PRODUCT NO. WG6 WG7 WG8 WG9 WGS11 XR11 XR11347 XR12206 XR12206347 XR12206C XR12208 XR12208347 XR12208C XR15 XR16 XR1624C XR16 XR17 XR20 XR20C XR21 XR21C XR3 XR3347 XR5 XR6C XR7 XR7C XR9 XR9C Z-67 Z-7 112 PAGE NO. 83 83 83 83 83 28 28 28 28 89 28 28 89 28 28 89 89 28 28 89 28 89 28 28 28 89 28 89 28 89 105 105 C O O P E R L I G H T I N G B R A N D FA M I LY MCGRAW-EDISON Durable, efficient HID fixtures illuminate a complete range of outdoor industrial utility and commercial applications. AMETRIX A complete vocabulary of point source indirect luminaires including ceiling, suspended, semi-recessed and cove versions available with compact fluorescent, tungsten-halogen, and metal halide light sources. PORTFOLIO Developing the visual design concept with lighting employs an intelligent ballance of art and science. Portfolio applies a similar approach to the design of luminaires with the controlled balance of visual comfort and efficiency. HALO Quality recessed, track and surface products serve a wide range of commercial, residential, institutional and industrial applications. INVUE Establishing a new benchmark in specification grade architectural site lighting, INVUE Lighting Systems bring together leading edge form and unmatched performance. NEO-RAY If yours is a never-ending quest to transform architectural spaces into dynamic environments, look to Neo-Ray for lighting products that offer a distinctive combination of high quality and aesthetics. FAIL-SAFE Security fixtures, control systems and specialty hardware built to withstand the rigors of correctional facilities, clean rooms, public access areas, hospitals and other high abuse environments. METALUX Single source fluorescent lighting for commercial, industrial, institutional, retail and residential markets. IRIS Aesthetics and performance combine for highly flexible architectural, residential and commercial lighting designs. LUMARK A full-line of quality commercial and industrial products to satisfy virtually every indoor or outdoor HID lighting need. LUMIERE Innovative solutions for complex landscape, area/accent and special application illumination. CORELITE Corelite offers a unique line of affordable architectural fluorescent luminaires perfectly suited to the creation of taskfriendly environments. RSA RSA is recognized as the leader in the development of cutting-edge, architectural lighting systems. As innovators in the design and manufacture of multi-lamp recessed, track and linear lighting, RSA products emphasize unique and functional design. The Power Behind The Brands. SHAPER Shaper's standard product line includes interior ceiling mounted and pendant luminaires, interior and exterior, wet listed wall mounted fixtures, a selection of exterior bollard designs and the “Starter Collection," geared to budget oriented projects. Customer First Center 1121 Highway 74 South Peachtree City, Georgia 30269 770 486 4800 Fax 770 486 4801 Domestic Facilities, USA Cranbury, New Jersey Elk Grove Village, Illinois Irving, Texas Ontario, California Peachtree City, Georgia International Sales, USA Cooper Lighting 1121 Highway 74 South Peachtree City, Georgia 30269 770 486 4800 Fax 770 486 4801 The Cooper Lighting Family Halo Metalux Lumark Sure-Lites Neo-Ray Corelite Portfolio Iris Shaper Lumière Invue McGraw-Edison Streetworks Fail-Safe MWS DLS RSA Ametrix Canada Cooper Lighting 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 905 507 4000 FAX 905 568 7049 Domestic Facilities, Canada Calgary, Alberta T2E 7V9 Chomedey, Laval P.Q. Cooper Lighting, Inc. All rights reserved Printed in USA Dimensions and specifications are subject to change without notice. www.cooperlighting.com ADX070284