Power Pack SPECIFICATIONS Voltages ............................................ 120/230/277VAC,50/60Hz Load Requirments Ballast ............................................... 20amp @120/277VAC Incandescent ............................................ 20amp @120VAC Motor ...................................................... 1HP @120/240VAC Output .......................225mA @24VDC (with relay connected) Low Voltage Input, Control ON ................................. 12-24VDC Operating Temperature ........................32°-104°F (0-40°C) WARRANTY INFORMATION Watt Stopper/Legrand warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of Watt Stopper/Legrand for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. Santa Clara, CA 95050 Installation Instructions BZ-50 DESCRIPTION The BZ-50 power pack is the foundation for any low voltage lighting control system. The BZ-50 supplies low voltage power to occupancy sensors and other control devices, switching line voltage in response to signals from control devices. The BZ-50 power pack is attached to existing junction boxes or mounted into fixture wiring trays. Low voltage wiring should use at least 22-gauge wire, high voltage connections should use at least 14-gauge. Always check local building codes. After initial wiring is complete, check wiring diagram to verify power pack is wired correctly. Improper wiring can cause damage to power pack, lighting system, and occupancy sensor. INSTALLATION WARNING TURN POWER OFF AT CIRCUIT BREAKER BEFORE INSTALLING POWER PACKS. WIRING High Voltage 1. Make sure power has been turned off at the circuit breaker. 2. Connect wires as shown in Fig.1 or Fig. 2. Low Voltage Class 2 Neut. BZ-50 White Red Switch Red Red Black Black Blue Line (optional) +24VDC Common Fig. 1: Single load control Lighting Load Control Output Any 3-Wire 24VDC Sensor Call 800.879.8585 for Technical Support Installation Notes 1. Power packs should be installed in accordance with state, local and national electrical codes and requirements. 2. Power packs are designed to attach to existing or new electrical enclosures with 1/2 inch knockouts. 3. Most applications require UL listed, 18-22 AWG, 3-conductor, Class 2 cable for low voltage wiring. For plenum return ceilings, use UL listed plenum-approved cables. 4. The BZ-50 is a Class 2 Ouput Power Supply, suitable for parallel interconnection of up to 10 units maximum. This powerpack is UL Listed for Interconnection of Power Sources in accordance with the National Electric Code. BZ-50 (A) Switch (optional) Blue Class 2 Low Voltage Wires Control Common +24VDC BZ-50 (B) Red Any 3-Wire 24VDC Sensor Lighting Load (B) Red Fig. 2: Parallel interconnect for multiple load control from a single sensor Blue Black Black Line White Red Neut. Lighting Load (A) Red Black Red Line Red White Black Neut. Class 2 Low Voltage Wires www.wattstopper.com OPERATION Low Voltage Input (Blue Wire): The blue wire carries the +12-24VDC maintained input Control ON signal to the BZ-50. Applying 12-24VDC to this input closes the BZ-50 load relay. Removing the voltage returns the relay to its normal state. This input is intended for sensor or control device input. Over Current Protection: The BZ-50 contains built-in short circuit and thermal protection circuitry that shuts down the +24VDC output (red wire to sensors) to prevent permanent damage to the power pack. Removing the excess load from the output restores the BZ-50 to proper operation. The excess load can be connected to another power pack. LED Indicator: The LED indicates the following conditions on the BZ-50: • LED OFF: no power to the BZ-50, or the +24VDC output is shorted. • LED ON, blinks once every 5 seconds: the relay is closed (load ON). • LED ON continuously: the relay is open (load OFF). • LED blinking continuously: current output limit is exceeded (too many sensors are connected to the power pack); +24VDC output shut down. Load Range ORDERING INFORMATION Catalog No. BZ-50 BZ-150 Description Power Pack Power Pack, Hold ON/OFF, Manual ON Input Voltage Ballast (A) Incan. (A) Motor (hp) 120/230/ 277VAC, 50/60Hz 20 20 1 120/230/ 277VAC, 50/60Hz 20 Output 24VDC, 225mA w/relay connected 20 1 24VDC, 225mA w/relay connected Please Recycle 2800 De La Cruz Boulevard, Santa Clara, CA 95050 Technical Support: 800.879.8585 • www.wattstopper.com 08406r3 08/2008
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : scsowinski Create Date : 2009:01:06 15:34:00-08:00 Modify Date : 2009:01:06 15:34:00-08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 9.0.0 (Windows) Format : application/pdf Title : ii BZ-50 08406r3 WEB.indd Creator : scsowinski Document ID : uuid:e87dab15-b083-4fc3-a403-49fbddfc989a Instance ID : uuid:befb45d8-5ca7-4b26-b3db-b94c7a5b02dc Page Count : 4EXIF Metadata provided by EXIF.tools