TTC 2010_Cover Backcover ENG 401267 Catalog
2014-07-05
: Pdf 401267-Catalog 401267-Catalog 095969 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 125
Download | |
Open PDF In Browser | View PDF |
Digital Multimeters Clamp Meters Electrical Testers Insulation Testers Earth Ground Testers Installation Testers Portable Appliance Testers Digital Thermometers Thermal Imagers Distance Meters Indoor Air Quality Tools Test Tools Catalog 2010/2011 Fluke. Keeping your world up and running.® ScopeMeter® Test Tools Power Quality Tools Vibration Tester Field Calibrators EX Test Tools Accessories Fluke Corporation P.O. Box 9090 Everett, WA USA 98206 Web: www.fluke.com Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands Web: www.fluke.eu For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/AFrica +31 (0)40 2 675 200) or Fax +31 (0)40 2 675 222 In Canada (905) 890-7600 or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Fluke (UK) Ltd. 52 Hurricane Way Norwich Norfolk NR6 6 JB United Kingdom Tel.: (020) 7942 0700 Fax.: (020) 7942 0701 E-mail: industrial@uk.fluke.nl Web: www.fluke.co.uk © Copyright 2010, Fluke Corporation. All rights reserved. Printed in the Netherlands, 04/10 Data subject to alteration without notice. Pub_ID: 11605-eng Test Tools Catalog 2010/2011 Contents Fluke web and electronic newsletter .................................................... 1 New from Fluke........................................................................................ 2-3 Fluke Combo Kits..................................................................................... 4-5 Application/background articles ...................................................... 6 Fluke After Sales Service ................................................................. 7 Fluke where safety is built in .......................................................... 8-9 Fluke Industrial Portal ..................................................................... 10 Fluke Electrical Portal....................................................................... 11 Fluke Process Portal.......................................................................... 12 Digital Multimeters ............................................................................ 13 DMM Selection Guide ....................................................................... 14 280 Series Digital Multimeters ....................................................... 15 233 Remote Display Multimeter ...................................................... 16 80 Series V Digital Multimeters ....................................................... 17 170 Series Digital Multimeters ........................................................ 18 110 Series II Digital Multimeters ..................................................... 19 77 IV Digital Multimeter ................................................................... 20 27 II/28 II Rugged Industrial Multimeters ..................................... 21 88V Automotive Meter...................................................................... 22 8845A/8846A 6.5 Digit Precision Multimeters ............................... 23 8808A 5.5 Digit Multimeter .............................................................. 24 Clamp Meters and Electrical Testers ................................................ 25 330 Series/902 Clamp Meters........................................................... 26 320 Series Clamp Meters .................................................................. 27 353/355 AC/DC Clamp Meters .......................................................... 28 360 Current Leakage Clamp Meter ................................................. 29 T100 Series Voltage/Continuity Testers .......................................... 30 T5/T5-H5-1AC Kit Electrical Testers................................................ 31 1AC-I/1AC-II/LVD1/LVD2 Voltage Detectors ................................... 32 9040/9062 Phase Rotation Indicators.............................................. 33 2042 Cable Locator ............................................................................ 34 Insulation Testers/Earth Ground Testers ......................................... 35 Insulation Tester Selection Guide ................................................... 36 1577/1587 Insulation Multimeters .................................................. 37 1503/1507 Insulation Testers ........................................................... 38 1550B MegOhmMeter........................................................................ 39 1620 Series Earth Ground Testers ................................................... 40 1621 Earth Ground Tester ................................................................. 41 1630 Ground Loop Tester .................................................................. 42 Laser Distance Meters ....................................................................... 64 421D/416D/411D Laser Distance Meters ........................................ 65 Indoor Air Quality Tools .................................................................... 66 975 Air Meter...................................................................................... 67 922 Airflow Meter .............................................................................. 68 971 Temperature Humidity Meter................................................... 69 983 Particle Counter .......................................................................... 70 ScopeMeter® Test Tools...................................................................... 71 ScopeMeter Test Tools ...................................................................... 72 120 Series ScopeMeters .................................................................... 73 190C Series, 215C/225C ScopeMeters ............................................ 74-75 ScopeMeter Accessories ................................................................... 76 Power Quality Tools ........................................................................... 77 Power Quality Selection Guide ........................................................ 78 1710 Plug-in Voltage Quality Recorder ......................................... 79 345 Power Quality Clamp Meter ...................................................... 80 43B Single-phase Power Quality Analyzer ..................................... 81 430 Series Three-phase Power Quality Analyzers......................... 82-83 1735 Power Logger ............................................................................. 84 1740 Series Power Quality Loggers.................................................. 85 1750 Power Recorder ......................................................................... 86 1760 Power Quality Recorder ........................................................... 87 Power Quality Current Clamp Accessories .................................... 88 Norma 4000/5000 Series ................................................................... 89-90 Field Calibrators ................................................................................. 91 Field Calibrator Selection Guide...................................................... 92 740 Series Documenting Process Calibrators ................................ 93 726/725/725Ex Multifunction Process Calibrators ....................... 94 724 Temperature Calibrator ............................................................. 95 712/714 Temperature Calibrators .................................................... 96 9140X/418X Drywells/IR Calibrators ............................................... 97 717/718/718Ex Pressure Calibrators ................................................ 98 706/707/707Ex/715 Loop Calibrators ............................................... 99 771/772/773 mA Clamp Meters....................................................... 100 787/789 ProcessMeters...................................................................... 101 Process Tools Accessories................................................................. 102 Vibration Tester.................................................................................. 103 810 Vibration Tester .......................................................................... 104 Installation Testers/Portable Appliance Testers .............................. 43 1650B Series Multifunction Installation Testers ........................... 44-45 6000 Series Portable Appliance Testers .......................................... 46-47 1650B/6000 Series Accessories ........................................................ 48 Digital Thermometers ....................................................................... 49 Infrared Thermometer Selection Guide ......................................... 50 570 Series Precision Infrared Thermometers ................................ 51 60 Series Infrared Thermometers ................................................... 52 566/568 Multipurpose Thermometers ............................................ 53 561 Multipurpose Thermometer ..................................................... 54 50 Series Thermometers .................................................................. 55 1523/1524 Reference Thermometers .............................................. 56 Thermal Imagers ............................................................................... 57 Ti Series Thermal Imagers ............................................................... 58 Hawk IR CRange IRWIndows ........................................................... 59 Ti19/Ti10 Electrical Thermal Imagers ............................................. 60 Ti25/Ti32 Industrial Thermal Imagers ............................................ 61 TiRx/TiR Thermal Imagers for Building Inspection ...................... 62 TiR1TiR32 Thermal Imagers for Building Diagnostics.................. 63 ATEX Certified Test Tools .................................................................. 105 A brief look at ATEX .......................................................................... 106 Fluke intrinsically safe tools............................................................ 107 General Accessories........................................................................... 108 Electronic Test Leads, Probes & Clips ............................................. 109 Industrial Test Leads, Probes & Clips.............................................. 110-111-112 Automotive Accessories ................................................................... 113 Current Clamps ................................................................................. 114-115 Temperature Accessories ................................................................. 116-117 Cases and Holsters............................................................................ 118-119 Software and Other Accessories ..................................................... 120 Other Accessories.............................................................................. 121 Product Quick Find List .................................................................... 122 Fuse and Warranty Information...................................................... 123 Fluke. Keeping your world up and running See page 122 for a Product Quick Find List per model number New from Fluke Fluke 233 Remote Display Multimeter The Fluke 233 allows you to be in two places at once. The removable display solves the problem of holding both the meter and the test leads to make a measurement. See page 16. Fluke 27 II/28 II Rugged Industrial Multimeters The Fluke 27 II and 28 II define a new standard for operating in harsh conditions with the features are accuracy to troubleshoot most electrical problems. Both multimeters have IP67 rating. See page 21. Fluke RLD2 Leak Detector Flashlight The Fluke RLD2 UV Flashlight uncovers refrigerant leaks instantly. Use the UV light to find the leakage area, then, use the laser pointer to pinpoint the exact leak location. See page 70. Fluke Ti32/Ti9 Industrial Thermal Imagers The Ti32 with its 320x240 sensor is the tool built for top professionals who need to see the smallest details. The affordable Fluke Ti9 puts the power of thermal imaging into the hands of electricians and technicians who are most familiar with the installations. See page 60 and 61. Fluke TiR32/TiRx Thermal Imagers for Buildings The Fluke TiR32 with its 320x 240 sensor features the highest level of thermal sensitivity to identify even small temperature differences. This makes it the ideal tool for building diagnostics. The Fluke TiRx is the perfect affordable thermal imager for building inspection. See page 62 and 63. Hawk-IR CRange IRWindows These arc-resistant, outdoor certified, infrared windows allow thermal, ultraviolet, visual and fusion technologies to be used without exposing personnel to live equipment. See page 59. 2 New from Fluke Fluke 1750 Power Recorder With its exclusive threshold-free measurement system, the Fluke 1750 Power Recorder captures every measurement, every event, on every cycle, all the time. Outstanding accuracy and resolution provide complete visibility into your installation or distribution system. See page 86. Fluke 421D Laser Distance Meter The Fluke 421D brings greater distance and advanced features to the Fluke laser distance meter family. It can measure a distance up to 100 m with 1/16 in accuracy and has a 45º tilt sensor for taking indirect measurements in hard to reach areas. See page 65. Fluke 772/773 Milliamp Process Clamp Meters The Fluke 772 and 773 measure 4 to 20 mA signals without “breaking the loop”, just like the popular Fluke 771. Now technicians in process plants, industrial plants, commercial buildings and automotive repair shops can choose exactly the range of capabilities they need, at a price that makes sense. See page 100. Fluke 810 Vibration Tester The Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now. The unique diagnostic technology helps you quickly identify and prioritize mechanical problems, putting the expertise of a vibration analyst in your hands. See page 104. FTPL Fused Test Probe Set The FTPL are test probes with built-in fuses for additional measurement protection. And, if the probe fuse does blow, these probes will still allow the meter to indicate live voltage helping to prevent a possible misreading of no voltage present. See page 111. 80PK-18 Pipe Clamp Temperature Probe Kit The 80PK-18 combines the standard 80PK-8 pipe clamp with the new larger sized 80PK-10 pipe clamp, to give you a full range of measurement sizes. The 80PK-10 can measure on pipe diameters van 32 mm to 64 mm. See page 116 and 117. 3 Fluke Combo Kits Buy a Combo Kit and save Fluke 117/322 Kit Electrician’s Combo Kit • Fluke 117 True RMS Multimeter • Fluke 322 Clamp Meter • TL75 Hard Point Test Lead Set • TPAK Magnetic Hanger • C115 Deluxe carrying case with shoulder strap Fluke 179/TPAK 179/ToolPak Combo Kit Fluke 117/322 Kit Fluke 179/TPAK Fluke 179/61 Kit Fluke 179/MAG2 Kit Fluke 179/EDA2 Kit Fluke 87V/E2 Fluke 87V/i410 4 • Fluke 179 True RMS Multimeter • TL224 SureGrip™ Silicone Test Lead Set • AC220 SureGrip™ Alligator Clip Set • TP4 Slim Reach Test Probe Set (4 mm) • TPAK Magnetic Hanger • 80BK-A Integrated DMM Temperature Probe • C35 Soft Meter Case • + Maglite flashlight Fluke 179/EDA2 Kit Electronics Combo Kit • Fluke 179 True RMS Multimeter • TPAK ToolPak Meter Hanging Kit • Fluke 179 True RMS Multimeter • TL224 SureGrip™ Silicone Test Lead Set • TL910 Electronic Test Probe Set • AC280 SureGrip™ Hook Clip Set • TPAK Magnetic Hanger • 80BK-A Integrated DMM Temperature Probe • C35 Soft Meter Case Fluke 179/61 Kit Multimeter and Infrared Thermometer Combo Kit Fluke 87V/E2 Industrial Electrician Combo Kit • Fluke 179 True RMS Multimeter • Fluke 61 Infrared Thermometer • C550 Hard Meter and Accessory Case Ordering Information Fluke 179/MAG2 Kit Industrial Combo Kit • Fluke 87V True RMS Multimeter • TL224 SureGrip™ Silicone Test Lead Set • TP38 Slim Reach Test Probe Set (insulated) • AC220 SureGrip™ Alligator Clip Set • TPAK Magnetic Hanger • 80BK-A Integrated DMM Temperature Probe • C35 Soft Meter Case Fluke 87V/i410 Combo Kit for Industrial Applications • 87V Industrial Multimeter • TL75 Test Leads • AC72 Alligator Clips • i410 400A AC/DC Current Clamp • 80BK-A Temperature Probe • C115 Soft Carrying Case (Not available in all countries) Fluke Combo Kits Buy a Combo Kit and save Fluke 287/FVF FlukeView Forms Combo Kit • Fluke 287 True RMS Electronic Logging Multimeter with TrendCapture • FVF-SC2 FlukeView Forms Software and cable • 80BK-A Thermocouple Probe • CAT III 1000 V 10 A Modular Test Leads (red, black) • CAT II 300 V 5 A Alligator Clips (red, black) • C280 Soft Case for meter protection and accessory storage Fluke 1587/MDT Advanced Motor & Drive Troubleshooting Kit • Fluke 1587 Insulation Multimeter • Fluke 9040 Phase Rotation Indicator • I400 Current Clamp Fluke 1587/MDT Fluke T5-H5-1AC Kit Fluke 289/FVF Industrial Logging Multimeter and Software Combo Kit • Fluke 289 True-RMS Multimeter • FVF-SC2 FlukeView Forms Software and cable • TL71 Silicon Test Lead Set • AC72 Alligator Clips • 80BK-A Integrated DMM Temperature Probe • TPAK Magnetic Meter Hanger for hands-free operation • C280 Soft Case for meter protection and accessory storage • Fluke T5-1000 Electrical Tester • H5 Holster • 1AC-II Volt Alert Fluke T5-600/62/IAC Kit • Fluke T5-600 Electrical Tester • Fluke 62 Mini IR Thermometer • Fluke 1AC-II Volt Alert • C115 Soft Meter Case Fluke 1587/ET Advanced Electrical Troubleshooting Kit • Fluke 1587 Insulation Multimeter • Fluke 62 Mini Infrared Thermometer • I400 Current Clamp Fluke 62/322/1AC Kit • Fluke 62 Mini IR Thermometer • Fluke 322 Clamp Meter • Fluke 1AC-II Volt Alert Ordering Information Fluke 287/FVF Fluke 289/FVF Fluke 1587/ET Fluke 1587/MDT Fluke T5-H5-1AC Kit Fluke T5-600/62/IAC Kit Fluke 62/322/1AC Kit Fluke 411D/62 Kit Fluke 411D/62 Kit • Fluke 411D Laser Distance Meter • Fluke 62 Mini IR Thermometer • Soft case for each model 5 Application/ background articles As part of our commitment to supporting you in your work we do more than just design and manufacture rugged and versatile test tools: we also provide application notes which all can be downloaded from our web site. Furthermore check our three new dedicated web portals: Industrial Portal, Electrical Portal and Process Portal. In addition to inspection tips and helpful application information, the portals also offer advice on picking the right tool for the job. 6 Let Fluke After Sales Service help you further Did you know that the Fluke after sales service team can offer you much more than just repairing and calibrating your instrument when it is needed? Across our whole Fluke European service organization we have a vast range of capabilities, which can be utilized via your local service centre. Behind the scenes Fluke draws on the expertise of over 150 service staff that are focused on offering only the best and most comprehensive after sales service. What other value added services do we offer? So why should you use Fluke service? • Original manufacturers’ parts used • All instruments reviewed for latest updates • Repair warranty that covers whole unit • In depth product knowledge • Accredited calibrations available • Traceable calibrations available on all products • Full check of unit during verification cycle • Full safety test on mains powered units What other instruments can we help you with? • Gold Support for Fluke Networks • Gold CarePlans for calibration products • A full range of maintenance contracts • Extended warranty programs • Instrument upgrades • Option retrofits • Asset management • Calibration reminders What services do we offer you? • 5 day repairs on all current products • 5 days or less on all calibrations (excl. repairs) • 3 days for all Gold CarePlan calibrations • 1-2 days on all Networks Gold calibration • Pick up services where available We also offer a range of calibrations and repairs on other manufacturer’s equipment upon request. Manufacturers such as: • Tektronix • Agilent • Bruel & Kjaer • Philips • Megger • Seaward • Kewtech • Lecroy • Hioki • Yokogawa • Druck • Iwatzu • plus many more ... Fluke service centres handle a wide range of equipment. As part of Fluke’s continuing focus on improving our service to our customer we now offer a comprehensive range of repairs and calibrations on a vast range of equipment. Fluke manufactures equipments such as: Fluke Brands Fluke Hart Scientific Fluke Networks Fluke Biomedical Raytek Reliable Power Meters Robin LEM Instruments BEHA Norma Wavetek/Datron Metron DHI Comark On-Line booking in system Why not use our On-Line booking in system where you can book your unit in, get pricing and receive a RMA number for a smooth return. www.fluke.com/servicerma Instrument Types Digital Multimeters Electrical Standards Biomedical Equipment Data Loggers Thermal Imagers Thermometers Pressure Function Generators Oscilloscopes Installation Testers PAT Testers Clamp Meters Power Analyzers EX meters Plus many more Contact Information Telephone Telefax Email Address Eindhoven +31 (0)40 267 5300 +31 (0)40 267 5321 servicedesk@fluke.nl Science Park 5108 Eindhoven 5692 EC Son Netherlands Norwich +44 (0)1603 256620 +44 (0)1603 256688 ukservicedesk@fluke.com 52 Hurricane Way Norwich Norfolk NR6 6JB United Kingdom Cologne +49 (0)69 2222 20210 +49 (0)69 2222 20211 servicedeskgermany@fluke.com Heinrich-Pesch-Str. 9-11 50739 Köln Germany 7 Fluke: Where safety is built in As distribution systems and loads become more complex, the possibilities of transient overvoltages increase. Motors, capacitors and power conversion equipment such as variable speed drives can be prime generators of spikes. Lightning strikes on outdoor transmission lines also cause extremely hazardous high-energy transients. If you’re taking measurements on electrical systems, these transients are “invisible” and largely unavoidable hazards. They occur regularly on low-voltage power circuits, and can reach peak values in the many thousands of volts. To protect you against transients, safety must be built into the test equipment. Who Develops Safety Standards? The IEC (International Electrotechnical Commission) develops international general standards for safety of electrical equipment for measurement, control and laboratory use. IEC61010-1 is used as the basis for the following national standards: • US ANSI/ISA-S82.01-94 • Canada CAN C22.2 No.1010.1-92 • Europe EN61010-1:2001 Overvoltage Installation Categories IEC61010-1 specifies categories of overvoltage based on the distance the piece of equipment is from the power source (see Fig. 1 and Table 1) and the natural damping of transient energy that occurs in an electrical distribution system. Higher categories are closer to the power source and require more protection. Within each installation category there are voltage classifications. It is the combination of installation category and voltage classification which determines the maximum transient withstand capability of the instrument. IEC 61010 test procedures take into account three main criteria: steady-state voltage, peak impulse transient voltage and source impedance. These three criteria together will tell you a multimeter’s true voltage withstand value. Figure 1. Understanding categories: location of the 12 Ω test source for CAT II. The CAT III 600 V meter clearly offers superior transient protection compared to the CAT II 1000 V meter, even though its so-called “voltage rating” could be perceived as being lower. See Table 2. Independent testing is the key to safety compliance How can you tell if you’re getting a genuine CAT III or CAT II meter? Unfortunately it’s not always that easy. It is possible for a manufacturer to self-certify that its meter is CAT II or CAT III without any independent verification. The IEC (International Electrotechnical Commission) develops and proposes standards, but it is not responsible for enforcing the standards. Look for the symbol and listing number of an independent testing lab such as UL, CSA, VDE, TÜV or other recognized approval agency. These symbols can only be used if the product successfully completed testing to the agency’s standard, which is based on national and international standards. UL 3111, for example, is based on EN61010-1. In an imperfect world, this is the closest you can come to ensuring that the meter you choose was actually tested for safety. Within a category, a higher working voltage” (steadystate voltage) is associated with a higher transient, as would be expected. For example, a CAT III 600 V meter is tested with 6000 V transients while a CAT III 1000 V meter is tested with 8000 V transients. So far, so good. What is not as obvious is the difference between the 6000 V transient for CAT III 600 V and the 6000 V transient for CAT II 1000 V. They are not the same. This is where the source impedance comes in. Ohm’s Law (Amps = Volts/Ohms) tells us that the 2 Ω test source for CAT III has six times the current Table 1 8 Overvoltage category CAT IV In brief Three-phase at utility connection, any outdoor conductors CAT III Three-phase distribution, including single-phase commercial lighting CAT II Single-phase receptable connected loads CAT I Electronic Examples • Refers to the “origin of installation”; i.e., where low-voltage connection is made to utility power. • Electricity meters, primary overcurrent protection equipment. • Outside and service entrance, service drop from pole to building, run between meter and panel. • Overhead line to d etached building, underground line to well pump. • Equipment in fixed installations, such as switchgear and polyphase motors. • Bus and feeder in industrial plants. • Feeders and short branch circuits, distribution panel devices. • Lighting systems in larger buildings. • Appliance outlets with short connections to service entrance. • Appliance, portable tools, and other household and similar loads. • Outlet and long branch circuits. • Outlets at more than 10 meters (30 feet) from CAT III source. • Outlets at more than 20 meters (60 feet) from CAT IV source. • Protected electronic equipment. • Equipment connected to (source) circuits in which measures are taken to limit transient overvoltages to an appropriately low level. • Any high-voltage, low-energy source derived from a high-winding resistance transformer, such as the high-voltage section of a copier. Overvoltage installation categories. IEC 61010-1 applies to low-voltage (< 1000V) test equipment Fluke: Where safety is built in Safety is everyone’s responsibility but ultimately it is in your hands. No tool by itself can guarantee your safety when working with electricity. It’s the combination of the right tools and safe work practices that gives you maximum protection. Here are a few tips to help you in your work: Make sure you always comply with (local) regulations. Work on de-energized circuits whenever possible. Use proper lock-out/tag-out procedures. If these procedures are not in place or enforced, assume that the circuit is live. Use protective gear when working on live circuits: • Use insulated tools • Wear safety glasses or a face shield • Wear insulated gloves, remove watches or jewelry • Stand on an insulated mat • Wear flame resistant clothing, not ordinary work clothes Select the right test tool: Inspect and test your test tool: • Choose a test tool rated to the highest category and voltage for which it could possibly be used (most often 600 or 1000 volt CAT III and/or 600 volt CAT IV). • Look for the category and voltage marking near the recessed input connectors of your test tool and a “double insulated” symbol on the back. • Verify your test tool has been tested and certified by two or more independent testing laboratories, such as UL in the United States and VDE or TüV in Europe by looking for the symbols of these agencies on (the back of) your test tool. • Make sure that the test tool is made of a high-quality, durable non-conductive material. • Check the manual to verify that the ohms, continuity and capacitance circuits are protected to the same level as the voltage test circuit, to reduce hazards when the test tool is used incorrectly in ohms, continuity or capacitance mode (if applicable). • Verify that the test tool has internal protection to prevent instrument damage when voltage is incorrectly applied to an amperage measurement function (if applicable). • Make sure that the amperage and voltage of your test tool’s fuses meets specifications. Fuse voltage must be as high or higher than the test tool’s voltage rating. • Be sure to use test leads that have: - Shrouded connectors - Finger guards and a non-slip surface - Category ratings that equal or exceed those of the test tool - Double insulation (look for the symbol) - A minimum of exposed metal on the probe tips • Check for a broken case, worn test leads or a faded display. • Make sure the batteries still deliver sufficient power to get reliable readings. Many test tools have a low battery indicator on the display. • Check the test leads resistance for internal breaks while moving the leads around (good leads measure 0.1-0.3 Ohm). • Use the meter’s own test capability to ensure that the fuses are in place and working right (see manual for details). Apply the appropriate working practices when measuring on live circuits: • Hook on the ground clip first, then make contact with the hot lead. Remove the hot lead first, the ground lead last. • Use the three-point test method, especially when checking to see if a circuit is dead. First test a known live circuit. Second, test the target circuit. Third, test the live circuit again. This verifies that your test tool worked properly before and after the measurement. • Hang or rest the test tool if possible. Try to avoid holding it in your hands, to minimize personal exposure to the effects of transients. • Use the old electrician’s trick of keeping one hand in your pocket. This lessens the change of a closed circuit across your chest and through your heart. For more information or to see the Electrical Safety video go to: United Kingdom: www.fluke.co.uk/safety Ireland: www.fluke.ie/safety E-Europe/Middle-East/Africa: www.fluke.nl/safety_ex Use protective equipment such as safety glasses and insulated gloves Table 2 Overvoltage Installation Category CAT I CAT I CAT II CAT II CAT III CAT III CAT IV Use meters with these markings: 1000 V CAT III or 600 V CAT IV Working Voltage (DC or AC RMS to ground) 600 V 1000 V 600 V 1000 V 600 V 1000 V 600 V Peak Impulse Transient (20 repetitions) 2500 V 4000 V 4000 V 6000 V 6000 V 8000 V 8000 V Test Source (Ω = V/A) 30 Ohm source 30 Ohm source 12 Ohm source 12 Ohm source 2 Ohm source 2 Ohm source 2 Ohm source Transient test values for overvoltage installation categories. (50 V/150 V/300 V values not included) 9 Fluke Industrial Web Portal Reduce downtime and unnecessary repairs Motors & drives Automation systems Power distribution Plant infrastructure Heavy loads Worn bearings Incorrect motor Wrong motor/drive connections Unbalanced harmonics Cable/ connection damage Equipment end-of-life Lack of maintenance Incorrect motor Overloading and mechanical strain could be signs that the motor is underperforming or inadequate for the job. Use an infrared thermometer to quickly locate hot spots, and see areas of excessive heat with a thermal imager to determine severity. A digital multimeter will determine if the current draw is too high, which is also a sign that the motor is inadequate for the demands placed on it. With a clamp meter measure the inrush current and high load currents. Fluke 568 Thermometer Fluke Ti32 Thermal Imager • High accuracy • Easy interface • Infrared and contact bead probe • Trending and reporting via PC • 320 x 240 sensor for clear, crisp images • IR-Fusion® blended thermal images • Rugged, withstands 2 m drop • High resolution and thermal sensitivity • Full analysis and reporting software included Fluke 87V True RMS Multimeter Fluke 337 True RMS Clamp Meter • Accurate frequency and voltage measurements on motor drives and electrically noisy environments. • Built-in thermometer • In-rush current function for motor starting, inductive lighting, etc. • AC/DC voltage and frequency measurements • Jaw opening 42 mm www.fluke.eu/industrial Visit the full portal with practical information about troubleshooting potential problems throughout the plant. See how to find the right test tool for the job. 10 Fluke Electrical Web Portal A solution for every application Electrical installation testing Power consumption Service/repair Electrical Installation Testing Setting up new installations, extending an existing installation or trouble shooting around safety is always crucial. To avoid any safety issues, with a multifunctional installation tester all safety measurement are combined in one single tester, testing a RCD or measuring the loop etc. A voltage tester is the every day tester when working in an electrical installation, quickly check voltage or continuity. The T5 with its OpenJawTM technology allows current measurement on tight spaces such as for example on a distribution board. Fluke 1650B Series Installation Testers • Insulation test, continuity test, high current loop test, RCD test, earth ground test • Slim probe with test button Fluke T5-1000 Electrical Tester • Voltage and continuity measurement • OpenJaw™ technology for current checks up to 100 A Fluke T120 Voltage and Continuity Tester • Voltage, continuity and resistance measurements • Three-phase rotation detection system www.fluke.eu/electrical Visit the full portal with practical information for the electrical installer. See how to find the right test tool for the job. 11 Fluke Process Web Portal Identifying potential problems Testing in Ex. Classified areas Automation Systems Maintenance and calibration of process instruments Instrument commissioning and service Measuring, troubleshooting 4-20mA loop signals Temperature calibrations Pressure calibrations Switch testing Custody transfer Troubleshooting process signals Measuring troubleshooting 4-20 mA loop signals Keeping manufacturing and processing plants running at maximum efficiency 24-hours a day requires regular inspection and troubleshooting of vital systems and equipment. 4-20mA control loops are the most common control signals used in process industries today. Troubleshooting the mA loop instruments, connections, and cables are an essential part of locating and reparing process control. Fluke 707Ex Loop Calibrator • Simultaneous mA and % • mA accuracy of 0.02% • Measure, source and simulate mA Fluke 725Ex Multifunction Process Calibator • Measure, source and view process signals simultaneously • Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters. Fluke 87VEx True RMS Multimeter • Accurate frequency and voltage measurements on motor drives and electrically noisy environments. • Built-in thermometer www.fluke.eu/process Visit the full portal with practical information about troubleshooting potential problems in the process control environment. See how to find the right test tool for the job. 12 Digital Multimeters Safety, quality and performance: three words that sum up the benefits of our extensive range of digital multimeters. Designed to help you do your job faster, more efficiently and with greater accuracy, there is a model for every budget and application. Choose from handheld troubleshooters to ultra smart instruments packed with features, including the ability to log and graph data, as well as high-precision bench units. 13 14 Basic features Counts True RMS readings Basic DC accuracy Wide bandwidth Auto/manual ranging Measurements Voltage AC/DC Current AC/DC Resistance Frequency Capacitance Temperature dB Conductance Duty cycle/pulse width Continuity with beeper/Diode test 4-20mA loop current as % readout Motor drive measurement RPM/Dwell VoltAlertTM, Non-contact voltage detection LoZ: low input impedance VCHEKTM LoZ Microamps Insulation test Number of insulation test ranges Display Dual display Analog bargraph Backlight Remote display Data storage and exchange Min-Max recording/with time stamp Fast Min-Max Display Hold/Auto (Touch) Hold Relative Stand alone logging/TrendCapture USB interface/RS232 interface Readings memories Other features Source 4-20mA loop current/24V loop supply Automatic selection, AC/DC volts Real time clock Smoothing Integrated holster Removable holster Closed case calibration Seperate battry/fuse access Completely sealed/watertight Automatic power off Low battery indication Warranty and safety Lifetime warranty/warranty (years) Input alert Dangerous voltage indication EN61010-1 CAT III EN61010-1 CAT IV See catalog page 287 O/O 6000 AC 0.25% 233 Remote display 20000 AC 0.05% 20 kHz O/O 87V 0.1% 5 kHz O/O 6000 83V High-end Industrial O/O 6000 AC 0.09% 179 O/O 6000 AC 0.09% 177 O/O 6000 AC 0.15% 175 Industrial maintenance and field service O/O 6000 AC 0.5% 117 Electrical O O O O O/O 250 μs O/O O O/O O/O 10000 O O O O/O O O O O O 1000 V 600 V 15 O O O O/O 250 μs O/O O O/O O/O 10000 O O O O/O O O O O O 1000 V 600 V 15 O 1000 V 600 V 16 3 O O/O O O O O O O O O 1000 V 600 V 17 O O O O O/- O/250 μs O/O O O O O O O O O 1000 V 600 V 17 O O O O O/- O/O O O/- O O O O 1000 V 600 V 18 O O O O O/O O O O/O O/- O O O 1000 V 600 V 18 O O O O O/O O O O/O O/- O O O 1000 V 600 V 18 O O O O O/O O O O/O O/- O O 600 V 19 19 3 O O O 600 V 3 O O O O O/- O O O O O/- O/- O/- O O O 19 O 600 V 3 O O O O O/- O/- O/- O O O/O O/O O 600 V 10 A 40 MΩ 50 kHz 10 mF O/O 6000 AC 0.5% 115 Field Service 600 V 200 μA 40 MΩ 50 kHz 10 mF +400ºC O/O 6000 AC 0.5% 116 HVAC/R O/- O/- O O O O 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 600 V 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 500 MΩ 40 MΩ 50 MΩ 50 MΩ 50 MΩ 50 MΩ 50 MΩ 40 MΩ 1 MHz 50 kHz 200 kHz 200 kHz 100 kHz 100 kHz 100 kHz 50 kHz 100 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF +1350ºC +400ºC +1090ºC +400ºC 60 dB 50 nS 60 nS 60 nS O/O O/O/O/O O/O O/O O/O O/O O/O O/O O/O O O O 1000 V 10 A 500 MΩ 1 MHz 100 mF +1350ºC 60 dB 50 nS O/O O/O 50000 50000 AC+DC AC+DC 0.025% 0.025% 100 kHz 100 kHz O/O O/O 289 Highest accuracy 113 19 O 600 V 3 O O O O O/- O O/- O/- O O O O/- 60 kΩ 40 MΩ 19 O 600 V 3 O O O O O/- O/- O/- O O O O/O 10 mF 600 V O/O 6000 AC 2.0% 600 V O/O 6000 AC 0.5% 114 Basic Electrical 28II 20000 AC 0.05% 50 kHz O/O O/O 0.3% 6000 77IV General Purpose O/O 0.1% 20000 88V Automotive O/O 4000 AC 0.1% 789 O O O 1000 V 600 V 21 O O O/O O O O O/O O O/- O O 60 nS O/O O/O O O O 1000 V 600 V 21 O O O/O O O O O/250 μs O/O O O O O 60 nS O/O O/O O 1000 V 600 V 20 O O O O O -/O O/- O O O/O O O O 1000 V 600 V 22 O O O O O/- O/250 μs O/O O O O O/- 60 nS O/O O/O 101 1000 V 3 O O O O/O O O/O O/O -/O O O/- O O O O/O O O/O 6000 AC 0.09% 1587 O/O 6000 AC 0.2% 1577 Insulation test 101 1000 V 3 O O O/- O O/- -/O O O/- O O O/O O O 1000 V 600 V 37 3 O O O O O/O O O/O O/- O O 5 O O/O O 1000 V 600 V 37 3 O O O O O/O O O 2 O/- 1000 V 1000 V 1000 V 1A 400 mA 400 mA 40 MΩ 50 MΩ 50 MΩ 20 kHz 100 kHz 10 mF +500ºC O/O 4000 AC 0.1% 787 Loop calibration 1000 V 1000 V 1000 V 1000 V 1000 V 10 A 10 A 10 A 10 A 1A 50 MΩ 50 MΩ 50 MΩ 50 MΩ 40 MΩ 200 kHz 200 kHz 100 kHz 200 kHz 20 kHz 10 mF 10 mF 10 mF 10 mF +1090ºC +1090ºC 0.1% 20 kHz O/O 6000 27II Heavy duty (IP67) DMM Selection guide 280 Series Digital Multimeters Advanced diagnostic and logging functionality for maximizing productivity Replacing the popular 180 Series, the Fluke 289 and Fluke 287 represent the next generation of high-performance industrial logging multimeters, including higher accuracy and greater troubleshooting convenience than ever before. With the ability to log data and review it graphically on the large display, you can solve problems faster and help minimize downtime, while working at several locations. • Large 50,000 count 320 x 240 (1/4 VGA) dot matrix display • Logging function with TrendCapture for easy review of logged data • Multiple readings per display provide more information at a glance • “I”-info button for convenient on-board help • PC interface for easy data transfer In addition, the Fluke 289 provides: • Lo Pass filter for motor drive measurements • LoZ – Low impedance function prevents false “ghost voltage” readings • 50 Ω range for motor winding and low ohm measurements Features Fluke 289 287 289 AC, AC+DC AC, AC+DC 100 kHz / 100 kHz 100 kHz / 100 kHz 50.000 / 50.000 50.000 / 50.000 O O O O Up to 180 h Up to 180 h O O O O O True-RMS measurements Bandwidth (voltage/current) Fluke 287 Digital display counts (default/selectable) Logging function with TrendCapture Records events and trends Internal memory Saves measurements Optical USB PC communications interface Low input impedance function (LoZ) Motor winding and low ohm measurement range 50 Ω O O O O O O O O O O O O Low pass filter O O O O O O O O O O O Field upgradeable/expandable meter Navigation keys F1-F4 soft keys/user function menus I-info button/on board help screens Precise performance View logged data graphically on screen Multilingual interface Saves preferred measurement setups Current measurement: 20 A (30 seconds momentary; 10 A continuous) Peak capture (records transients as fast as 250 μs) Continuity measurement Min/Max/Average with Time Stamp (records signal fluctuations) IP Rating 54 Specifications (Check the Fluke web for detailed specifications) True RMS Included Accessories TL71 silicone test leads, probe holder, 6 AA batteries (installed), user manual, Calibration Certificate Sheet. Ordering Information Fluke 287 True-RMS Electronic logging multimeter with TrendCapture Fluke 289 True-RMS Industrial logging multimeter with TrendCapture Fluke 289/FVF Industrial logging multimeter and Software Combo Kit (see page 5) Fluke 287/FVF FlukeView Forms Combo Kit (see page 5) FVF-SC2 FlukeView Forms software including IR/USB cable Functions Maximum Max. resolution 287 and 289** Voltage DC 1000 V 1 μV ±(0.025% + 5) Voltage AC 1000 V 1 μV ±(0.4% + 40) Current DC 10 A 0.01 μA ±(0.15% +2) Current AC 10 A 0.01 μA ±(0.7% + 5) Temperature -200 ºC to 1350 ºC 0.1 ºC ±(1.0% + 1 ºC) Resistance 500 MΩ 0.01 Ω ±(0.05% + 2) Conductance 50 nS 0.01 nS ±(1.0% + 10) Capacitance 100 mF 0.001 nF ±(1.0% + 5) Frequency 1 MHz 0.01 Hz ±(0.005% + 1) Accuracies are best accuracies for each function. ** 287 and 289 accuracy and resolution are stated for 50.000 counts Battery life: 50 hours minimum, 180 hours in logging mode Size (HxWxD): 222 mm x 102 mm x 60 mm Weight: 0,871 kg Lifetime warranty Recommended Accessories TLK289 See page 111 TL910 See page 109 TLK287 See page 109 TPAK See page 109 C280 See page 118 15 233 Remote Display Multimeter New Ultimate flexibility with removable display The NEW Fluke 233 remote display digital multimeter allows you to be in two places at once. The removable display solves the problems of holding both the meter and the test leads to make a measurement, making measurements in hard-to-reach places, and making measurements in machines or panels that are physically separated from a limit switch or an isolator switch. Wireless technology allows the display to be carried up to 10 meters away from the point of measurement. The Fluke 233 is also designed to work in areas where the operator can’t be close to the active measurement point, like clean rooms or hazardous areas. Features 233 Removable magnetic display O True-RMS measurement O Digital display counts 6000 Display backlight O Built in thermometer O Resistance, continuity and diode test O Min/Max and average recording O Auto power off maximizes battery life O Radio transmitter automatically turns off when the display is connected to the meter O Use as conventional multimeter when the display is connected O Safety rating CAT IV 600 V / CAT III 1000 V Auto and manual ranging Fluke 233 O Display Hold and AutoHOLD O Unsafe voltage alert warns for voltages above 30V O 2 Low batteries indication O Ergonomic case with integrated holster O Selectable sleep mode preserves battery life O ® Specifications On all inputs Functions True RMS Included Accessories Test leads with 4mm lantern tips and protective cap, AC 72 alligator clips, 80BK-A temperature probe, CD-ROM, AA batteries and user manual. Voltage DC Voltage AC Current DC Current AC Resistance Capacitance Frequency Temperature Wireless frequency: 2.4 GHz ISM Band 10 meter range Maximum 1000 V 1000 V 10 A 10 A 40 MΩ 9999 μF 50.00 kHz -40 ºC to +400 ºC Fluke 233 Max. Resolution 0.1 mV 0.1 mV 1 mA 1 mA 0.1 Ω 1 nF 0.01 Hz Accuracy ±(0.25% + 2) ±(1.0% + 3) ±(1.0% + 3) ±(1.5% + 3) Accuracies are best accuracies for each function Ordering Information Fluke 233 Remote Display Multimeter Battery Life: AA alkaline (3 for main body, 2 for display), 400 hrs typical Size (HxWxD): 193 x 93 x 53 mm Weight: 0.6 kg Three year warranty Recommended Accessories 80AK-A See page 116 16 80PK-9 See page 116 i410 See page 115 Tpak See page 120 C35 See page 118 80 Series V Digital Multimeters Performance and accuracy for maximum industrial productivity The Fluke 80 Series V have improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution, and electro-mechanical equipment. The Fluke 87V has a unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment. A built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument. For 87V Ex see also page 106 and 107. Features 83V Fluke 83V 5 kHz 20 kHz Digital display counts (default/selectable) 6000 20000 / 6000 Selectable filter for accurate voltage and frequency measurements on motor drives Large display with analog bargraph and 2 level bright white backlight Auto and manual ranging for maximum flexibility Fluke 87V 83V/87V 87V / 87V Ex O True-RMS voltage and current for accurate measurements on non linear signals Bandwidth (voltage/current) O O O O O Built-in thermometer lets you carry one less tool O Peak capture to record transients as fast as 250 μs O Relative mode to remove test lead resistance from low ohms measurements Min-Max-Average recording with Min/Max Alert to capture variations automatically AutoHOLD® to capture stable readings avoiding noisy signals Audible continuity, diode test and duty cycle O O O O O O O O Input Alert O O “Classic” design with new removable holster with built in test lead and probe storage Improved selectable sleep mode for long battery life O O O O Easy battery exchange without opening the complete case O O ATEX safety rating 87V Ex II 2 G Eex ia IIC T4 Specifications On all inputs (Check the Fluke web for detailed specifications) Fluke 87V Ex Functions True RMS not 87V Ex Included Accessories TL75 test leads, AC72 alligator clips, yellow holster (H80M excl. TPAK), 80BK temperature probe (87V only), 9 V battery (installed), CD-ROM (user’s manual and technical notes) and operator’s guide. Ordering Information Fluke 83V Multimeter Fluke 87V True RMS Multimeter Fluke 87V Ex Intrinsically safe True RMS multimeter Fluke 87V/E2 Industrial Electrician Combo Kit See page 4 Voltage DC Voltage AC Current DC Current AC Resistance Conductance Capacitance Frequency Temperature 80BK temperature probe Maximum Range 83V 87V/87V Ex* Max. resolution Accuracy Max. resolution Accuracy 0.1 mV 0.1 mV 0.1 μA 0.1 μA 0.1 Ω 0.01 nS 0.01 nF 0.01 Hz ±(0.1%+1) ±(0.5%+2) ±(0.4%+2) ±(1.2%+2) ±(0.4%+1) ±(1.0%+10) ±(1.0%+2) ±(0.005%+1) - 10 μV 10 μV 0.01 μA 0.01 μA 0.01 Ω 0.001 nS 0.01 nF 0.01 Hz 0.1 ºC - ±(0.05%+1) ±(0.7%+2) ±(0.2%+2) ±(1.0%+2) ±(0.2%+1) ±(1.0%+10) ±(1.0%+2) ±(0.005%+1) 1.0% 2.2 ºC or 2% 1000 V 1000 V 10 A ** 10 A ** 50 MΩ 60 nS 9999 μF > 200 kHz -200 to 1090 ºC -40 to 260 ºC Accuracies are best accuracies for each function. * 87V accuracy is stated for 6000 counts and resolution for 20000 counts ** 20 A up to 30 seconds Battery Life: Over 400 hours typical (alkaline). Size (HxWxD): 200 mm x 95 mm x 48 mm Weight: 0.6 kg 83V/87V: Lifetime Warranty 87V Ex: One Year Warranty Recommended Accessories (Not for hazardous zones) C25 See page 118 TL238 See page 110 i410/i1010 See page 115 TPAK See page 120 L215 See page 111 17 170 Series Digital Multimeters Versatile meters for field service or bench repair These meters have the features needed to find most electrical, electromechanical and heating and ventilation problems. They are simple to use and have significant improvements over Fluke’s original 70 Series like True-RMS, more measurement functions, conformance to the latest safety standards, and a much larger display that’s easier to view. Features True-RMS measurements 175 AC 177 AC 179 AC Digital display counts, updates 4 times per second 6000 6000 6000 O O Display backlight Fluke 177 Fluke 179 Fluke 175 Analog bargraph / 33 segments, updates 40 times per second Auto and Manual ranging O O O O O O Display Hold and AutoHOLD® O O O Min-Max-Average recording mode with Min/Max Alert O O O Temperature readings (bead thermocouple probe included) Smoothing mode allows filtering of rapidly changing inputs Audible continuity and diode test O O O O O O Test lead alert O O O Unsafe voltage alert warns for voltages above 30V O O O Low battery indication O O O Ergonomic case with integrated holster O O O Easy battery and fuse exchange without opening the complete case Selectable sleep mode preserves battery life O O O O O O O Specifications On all inputs (Check the Fluke web for detailed specifications) True RMS Included Accessories Test leads with 4 mm lantern tips and protective cap, installed 9V battery and users manual. The 179 also includes the 80BK temperature probe. Ordering Information Fluke 175 Fluke 177 Fluke 179 Fluke 179/EDA2 Kit Fluke 179/MAG2 Kit True RMS Multimeter True RMS Multimeter True RMS Multimeter Electronics Combo Kit Industrial Combo Kit See page 4 Functions Voltage DC Voltage AC Current DC Current AC Resistance Capacitance Frequency Temperature Max. resolution 0.1 mV 0.1 mV 0.01 mA 0.01 mA 0.1 Ω 1 nF 0.01 Hz 0.1 ºC 175 ±(0.15%+2) ±(1.0%+3) ±(1.0%+3) ±(1.5%+3) ±(0.9%+1) ±(1.2%+2) ±(0.1%+1) 177 ±(0.09%+2) ±(1.0%+3) ±(1.0%+3) ±(1.5%+3) ±(0.9%+1) ±(1.2%+2) ±(0.1%+1) 179 ±(0.09%+2) ±(1.0%+3) ±(1.0%+3) ±(1.5%+3) ±(0.9%+1) ±(1.2%+2) ±(0.1%+1) ±(1.0%+10) Accuracies are best accuracies for each function Battery Life: Alkaline, 200 hrs typical Size (HxWxD): 190 mm x 85 mm x 45 mm Weight: 0.42 kg Lifetime Warranty Recommended Accessories i400 See page 114 18 Maximum 1000 V 1000 V 10 A 10 A 50 MΩ 10000 μF 100 kHz -40 ºC/+400 ºC C90 See page 118 TLK-220 See page 110 SV225 See page 121 i410-i1010 See page 115 110 Series Digital Multimeters Compact design for ergonomic one-handed operation Fluke 115 Field Service Testing Multimeter The Fluke 110 Series has five true-rms DMMs, each for specific users. The compact instruments offer convenient one-handed operation and a backlit display with large, easyto-read digits. An everyday multimeter for technicians, the 115 is for electrical and electronic testing in field service, industrial, and applications where more than the basic functions simplify work. Fluke 117 Electrician’s Multimeter with Non-Contact Voltage Fluke 115 Fluke 114 Electrical Multimeter The 117 is for electricians working in commercial and non-commercial premises (like hospitals and schools). It includes extras like non-contact voltage detection for faster and safer operation. The 114 is for electrical troubleshooting and straightforward ‘go/no-go’ in residential/ commercial testing. It has all the basic functions plus a special feature to prevent false readings caused by ghost voltage. Fluke 116 Multimeter with Temperature and Microamps Fluke 113 Multimeter The 113 is for basic electrical tests and repairing most electrical problems. Features include Fluke’s VCHEK™, added measurement functions, backlight and conformance to the latest safety standards. The 116 is for heating, ventilation and air conditioning (HVAC) engineers. It includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems. Fluke 117 Features 113 114 115 116 AC AC AC AC AC 6000 6000 6000 6000 6000 Backlight O O O O O Analog bargraph O O O O O True RMS readings Counts Fluke 114 O AutoVolt: Automatic AC/DC voltage selection 117 O O O VoltAlert™, Non-contact voltage detection O Built-in thermometer for HVAC applications O LoZ: low input impedance to prevent ghost voltage VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity O Min/Max/Average to record signal fluctuations O O Resistance, continuity O O -/ O/O Frequency, Capacitance, Diode test O O O O O O O O O O O O Microamps to test flame sensors Fluke 116 Display hold O O O O O Auto/manual ranging O O O O O Low battery indication O O O O O Compact case with removable holster O O O O O Specifications (Check the Fluke web for detailed specifications) Functions Fluke 113 On all inputs True RMS Included Accessories Voltage DC Maximum 600V Max. resolution 1mV 113 114 115 116 117 ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(1.0%+3) ±(1.0%+3) ±(1.0%+3) ±(1.0%+3) Voltage AC 600V 1mV Current DC 10.00A 1mA ±(1.0%+3) Current AC 10.00A 0.01A ±(1.5%+3) Resistance 40MΩ (113: 60KΩ) 0.1Ω ±(0.9%+2) Capacitance 10000μF 1nF ±(1.9%+2) Frequency 50kHz 0.01Hz Temperature -40°C/+400°C 0.1°C VCHEK™ 600.0V AC/DC 0.1V ±(0.9%+1) ±(0.9%+1) ±(1.0%+3) ±(1.5%+3) ±(0.9%+1) ±(1.9%+2) ±(1.9%+2) ±(1.9%+2) ±(0.1%+2) ±(0.1%+2) ±(0.1%+2) ±(1.0%+2) Test leads with 4 mm lantern tips and protective cap, holster, installed 9V battery and users manual Accuracies are best accuracies for each function Ordering Information Battery type: 9 volt Alkaline, 400 hours typical Weight: 0.55 kg (including batteries) Size (HxWxD): 167 mm x 84mm x 46 mm Three Year Warranty Fluke 113 Fluke 114 Fluke 115 Fluke 116 Fluke 117 Fluke 117/322 Kit True RMS Multimeter True RMS Multimeter True RMS Multimeter True RMS Multimeter True RMS Multimeter Electricians Combo Kit (see page 4) ±(0.9%+1) ±(2.0%+3) Recommended Accessories C50 See page 118 TL223 See page 110 MC6 See page 121 TPAK See page 120 19 77IV Digital Multimeter Versatile multimeter for field service or bench repair The 77-IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke’s original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that’s easier to view. Features 77 IV 6000 O O O 31 O O O O O CAT IV 600 V / CAT III 1000 V Digital display counts Large display with backlight Min-Max-Average recording mode with Min/Max Alert High contrast digital display with large digits Analog bargraph/segments Auto and Manual ranging Automatic Touch Hold® Audible continuity / diode test Ergonomic case with integrated holster Sleep Mode preserves battery life EN 61010-1 safety rating Fluke 77 IV Specifications Function Voltage DC Voltage AC Current DC Current AC Resistance Capacitance Frequency Maximum 1000 V 1000 V 10 A 10 A 50 MΩ 9999 μF 99.99 kHz Max. resolution 1 mV 1 mV 0.01 mA 0.01 mA 0.1 Ω 1 nF 0.01 Hz Accurancy ±(0.3%+1) ±(2.0%+2) ±(1.5%+2) ±(2.5%+2) ±(0.5%+1) ±(1.2%+2) ±(0.1%+1) Accuracies are best accuracies for each function. Battery Life: 400 hours typical Weight: 0.42 kg Size (HxWxD): 185 mm x 90 mm x 43 mm Lifetime Warranty On all inputs Recommended Accessories Included Accessories TL75 test leads, operator’s manual, 9V battery (installed) Ordering Information Fluke 77IV 20 Multimeter i400 See page 114 C35 See page 118 Tpak See page 120 TL225 See page 121 TLK-225 See page 111 27II / 28II Rugged IP67 Industrial Multimeters Designed to survive water, dust and rough handling and yet troubleshoot most electrical problems New The NEW Fluke 27 II and 28 II digital multimeters define a new standard for operating in harsh conditions with the features and accuracy to troubleshoot most electrical problems. Both meters have IP 67 (waterproof and dustproof) rating, MSHA approvals (pending), extended operating temperature range of -15° C to + 55°C and 95% humidity, and a 3-meter drop. They withstand hazardous 8.000 volt spikes caused by load switching and faults on industrial circuits and complies with second edition IEC and ANSI electrical safety standards. Furthermore, the 28 II has a unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment. The new Fluke 20 series multimeters are built to work in the toughest environments. Features 27 II 28 II IP 67 waterproof & dustproof protection O O Withstands 3 meter drop (with holster) O O True-RMS measurements Fluke 27 II O Digital display counts 6000 20000/6000 Bright, two-level backlight O O Backlit keypad buttons O O Reversible, rubber holster O O Resistance, continuity and diode test O O Min/Max and average recording O O Improved sleep mode for long battery life O O Relative mode to remove test lead resistance from low ohms measurements O O Auto and manual ranging O O CAT III 1000 V CAT IV 600 V CAT III 1000 V CAT IV 600 V Built-in thermometer O Safety rating Specifications True RMS Fluke 28 II Functions Maximum Voltage DC Voltage AC Current DC Current AC Temperature On all inputs 1000 V 1000 V 10 A 10A Max. Resolution 0.1 mV 0.1 mV 0.1 μA 0.1 μA 27 II 28 II ±(0.1% + 1) ±(0.5% + 3) ±(0.2% + 4) ±(1.5% + 2) Resistance Low pass filter (Measurement on VSD’s) Capacitance Frequency Peak transient capture ±(0.05% + 1) ±(0.7% + 4) ±(0.2% + 4) ±(1.0% + 2) -200 ºC to +1090 ºC 0.1 Ω to 50 MΩ yes 1 nF to 9999 μF 0.5 Hz to 199.99 kHz 250 μS Accuracies are best accuracies for each function Battery Life: 3x AA alkaline, 800 hrs typical Size (HxWxD): 198 x 100 x 63.5 mm Weight: 0.75 kg Lifetime Warranty Included Accessories TL 75 Test leads, AC 72 alligator clips, 80BK-A temperature probe (28 II), holster, manual, CD-ROM, three AA batteries (installed) Recommended Accessories Ordering Information Fluke 27 II IP 67 Industrial Multimeter Fluke 28 II IP 67 True-RMS Industrial Multimeter PV 350 See page 113 i200 See page 114 i410 See page 115 80K-6 See page 121 21 88V Automotive Meter The right meter for auto-electric diagnosis Perhaps the most important tool you’ll use in troubleshooting auto electrical systems is the multimeter. Basic multimeters measure voltage, current and resistance, while automotive multimeters like the Fluke 88V have features that can check frequency, duty cycle, make diode tests, and measure temperature, pressure and vacuum. Features Continuity for detecting open and shorts 88V/A O Frequency for “pulsed-DC” and AC tests O Duty cycle to verify operation of feedback carburetors O Diode test for alternator testing O Built-in thermometer; thermocouple probe included O Min/Max/Average recording with Min/Max Alert O Peak capture to record transients as fast as 250 μs O Relative mode to remove test lead resistance from low ohms measurements O Millisecond pulse width measurements for fuel injectors O AutoHOLD® to capture stable readings O Large display with bright, two-level backlight O Magnet hanger to attach meter to the vehicle O RPM80 Inductive Pickup for both conventional and distributorless (DIS) ignitions O Fluke 88V/A Hard Meter Case O Safety rating CAT III 1000 V, CAT IV 600 V Specifications On al inputs Included Accessories H80M Holster with TPAK Meter Hanging Solution, TL224 SureGrip Silicone Test Lead Set, TP220 SureGrip Test Probe Set, AC285 SureGrip Large Jaw Alligator Clip Set, 80BK Integrated Temperature Probe, RPM80 Inductive Pick-up Probe, C800 Hard Case, User’s Manual + Quick Reference Guide Range 1000V 1000V (5 kHz) 10A 10A 50MΩ 10mF 200kHz 1090ºC Voltage DC Voltage AC Current DC Current AC Resistance Capacitance Frequency Temperature Fluke 88V Resolution 0.1mV 0.1mV 0.1μA 0.1μA 0.1Ω 0.01nF 0.01Hz 0.1ºC Accuracy 0.1% 0.5% 0.4% 1.2% 0.4% 1% 0.005% 1% Battery Life: 88V – Over 400 hours typical Weight: 88V – 0.36 kg (alkaline) Lifetime Warranty Size (HxWxD): 88V – 186 mm x 86 mm x 32 mm Ordering Information Fluke 88V/A Automotive Meter Combo Kit Recommended Accessories TL82 See page 113 22 TLK-282 See page 113 90i-610s See page 113 80PK-27 (requires 80AK) See page 116 PV350 See page 113 8845A/8846A 6.5 Digit Precision Multimeters Precision and versatility for bench or systems applications The Fluke 8845A and 8846A, 6.5 digit precision multimeters have the precision and versatility to handle your most demanding measurements on the bench or in a system. Fluke 8845A Perform 4-wire measurements easily with two leads: Patented split terminal jacks for 2x4 Ohms function allows you to perform precise 4-wire measurements with only two leads instead of four. Optional Kelvin leads accessories are available to enable you to establish a 4wire connection even in tight spaces. Systems Capabilities: Both instruments include an RS-232, IEEE-488 and Ethernet interface as standard, with popular DMM emulation modes makes systems integration a simple task. Software: Transfer data points from your meter to your PC with the free copy of FlukeView Forms Basic. To customize your forms upgrade with FVF-UG. Dual Display offers versatile graphical capabilities: The 8845A and 8846A features a unique graphical display that can reveal signal quality issues like drift, intermittent and stability by viewing the measurement data as a real time TrendPlot™, Histogram or Statistics using the unique analyze mode. Wide Measurement Ranges: Resistance or current has been extended to cover the widest range possible. Fluke 8846A Features 8845A Use the built-in TrendPlot paperless chart recorder to graphically identify the extent of drift and intermittent events in analog circuits Display Resolution Measurement Rate (Rdgs/s) Continuity / Diode Test Analytical Functions Math Functions USB Device Port Real Time Clock Interfaces Programming Languages/ Emulation Modes Safety View results in Histogram mode to reveal stability or noise problems in analog circuits 8846A Dual VFD Dot Matrix 6.5 Digits 1000 Yes Statistics, Histogram, TrendPlot™, Limit Compare NULL, Min/Max, dB/dBm – USB Memory Drive port – Yes RS232, IEEE-488.2, Ethernet SCPI (IEEE-488.2), Agilent 34401A, Fluke 45 Designed to comply with IEC 61010-12000-1, ANSI / ISA-S82.01-1994, CAN / CSA-C22.2 No.1010.1-92 1000V CATI / 600V CATII Specifications (Check the Fluke web for detailed specifications) 8845A Handle even the most demanding measurements with high accuracy and 6.5 digit resolution True RMS Included Accessories LCI Line Power Cord, TL71 Test Lead Set, Spare Line Power fuse, Programmers Manual/ User Manual on CD-ROM, 884X-USB USB to RS232 Cable Adapter, FVF-BASIC FlukeView Forms Software Basic Version. Function* Voltage DC Voltage AC (Freq 300 Hz) Resistance (2x4 Wire) Current DC Current AC (Freq. 3Hz-10kHz) Freq/Period Capacitance Temperature RTD Resolution Accuracy* (%) Range Resolution Accuracy* (%) 1000 V 750 V 100 MΩ 10 A 10 A 300 kHz - 100 nV 100 nV 100 μΩ 100 pA 10 μA 1 μHz - 0.0035 0.06 0.01 0.05 0.10 0.01 - 1000 V 1000 V 1 GΩ 10 A 10 A 1 MHz 1 nF to 0.1 F -200 to +600º 100 nV 100 nV 10 μΩ 100 pA 100 pA 1 μHz 1 pF 0.001º 0.0024 0.06 0.01 0.05 0.10 0.01 1 0.06 * Accuracy =+/- (% of reading) Size (HxWxD): 88 mm x 215 mm x 293 mm Weight: 3.6 kg Three Year Warranty Recommended Accessories Ordering Information Fluke 8845A 6.5 Digit Precision Multimeter Fluke 8845A/SU 6.5 Digit Precision Multimeter (software + cable) Fluke 8846A 6.5 Digit Precision Multimeter Fluke 8846A/SU 6.5 Digit Precision Multimeter (software + cable) Calibration & Service agreements 8846A Range 884X-case Hard case TL2X4W-TWZ 2x4 Wire Ohms Tweezer Test Leads TL2X4W-PT II 2x4 Wire Ohms Test lead 2mm Probe Tip 884X-512M USB Memory 512M FVF-UG FlukeView Forms Software Upgrade 23 8808A 5.5 Digit Multimeter Versatile multimeter for manufacturing, development and service applications Fluke 8808A Manufacturing test, R&D, development and service applications demand performance and flexibility from a bench meter. The Fluke 8808A delivers a wide variety of measurement functions, including volts, ohms, and amps, plus frequency - all at superior accuracy and resolution with a basic V dc accuracy of 0.015 %. Measure sensitive leakage current: The Fluke 8808A includes two low impedance low current ranges for measuring sensitive leakage currents (i-Leakage). The Fluke 8808A includes two low impedance low current ranges for measuring sensitive leakage currents Use setup keys (S1-S6) for fast access to repetitive measurements. Setups can include limit compare mode with pass/fail indicators Eliminate production mistakes: The 8808A has a limit compare mode with built in display enunciators that clearly show whether a test is within or out of limits. Perform 4-wire measurements with only two leads: Patented split terminal jacks for 2x4 Ohms function allow you to perform precise 4-wire low ohms measurements with only two leads instead of four. Optional test lead accessories are available to enable you to establish a 4-wire connection even in tight spaces or on surface mount devices. Perform routine manufacturing functional tests with consistency: Use setup keys (S1 – S6) for fast access to repetitive measurements. Operators no longer need to press multiple buttons to make routine measurements. Features 8808A VFD multi segment 5.5 digits V ac, V dc, I dc, I ac, Ω, Cont, Diode 2X4 Wire Ohms, Freq, i-Leakage Yes Limit Compare dBm, dB, Min, Max RS-232, USB via optional adapter Simplified ASCI, Fluke 45 CAT I 1000 V, CAT II 600 V Display Resolution Measurements Advanced Measurements Continuity / Diode Test Analytical Functions Math Functions Interfaces Programming Languages/Modes Safety Rating Specifications (Check the Fluke web for detailed specifications) Functions Voltage DC Voltage AC (Freq. 10 Hz to 100 kHz) Resistance (2x4 Wire) Dual Display True RMS Range 200 mV to 1000 V 200 mV to 750 V 1 μV 1 μV Accuracy* 0.015 0.2 200 Ω to 100 MΩ 1 mΩ 0.02 Current DC 200 μA to 10 A 1 nA 0.02 Current AC (Freq. 20 Hz to 2 kHz) Freq. Period 20 mA to 10A 100 μA 0.3 20 Hz to 1 MHz (Freq. only) 0.1 mHz 0.01 Included Accessories * Accuracy = +/- (% of reading) LCI Line Power Cord, TL71 Test Lead Set, Spare Line Power fuse, 884X-USB USB to RS232 Cable Adapter, FlukeView Forms Software Basic Version, Programmers Manual/User Manual on CD-ROM. Size (HxWxD): 88 mm x 217 mm x 297 mm Weight: 2.1 kg Three year Warranty Recommended Accessories Ordering Information Fluke 8808A Fluke 8808A/SU Fluke 8808A/TL 24 Resolution 5.5 digit multimeter 5.5 digit multimeter, (software & cable) 5.5 digit multimeter, 2X4W Test Lead Kit TL2X4W-TWZ 2x4 Wire Ohms Tweezer Test Leads 884X-case Hard case TL2X4W-PT II 2x4 Wire Ohms Test lead 2mm Probe Tip 884X-short 4-Wire Short FVF-UG/SC4/SC5 FlukeView Forms Software Clamp Meters and Electrical Testers The ergonomic clamp meters feature wide opening jaws for safe, fast non-contact current measurement. The Fluke leakage clamp meter is ideal for non-invasive checks of insulation resistance. The range of electrical testers includes two-pole testers for taking quick measurements in tight spaces, phase rotation indicators to take the guess work out of checking phase/motor rotation, a multipurpose cable locator and handy voltage alerts. 25 330 Series/902 Clamp Meters Expanded capabilities for current measurement Fluke 336 Fluke 335 The Fluke 330 Series Clamp Meters offer all the features you need to fit the way you work. The small body and jaws fit perfectly in your hand and into tight places. Meter controls are positioned so that current measurements can be down with one hand. A large backlit display (on most models) is easy to see and a handy Display Hold keeps measurements on the display. Measuring starting current for motors, lighting, etc. is easy with the inrush current function (on most models). The Fluke 902 adds temperature and capacitance measurement capabilities to the line, ideal for heating, ventilation and air conditioning system inspections. Features Functions True-RMS Display backlight Auto shut-off Display Hold Motor start-up current Low battery indication Large jaw Min/Max Current AC/DC Temperature Fluke 334 Fluke 333 333 334 335 O O O O O O O O O O O O O O 336 O O O O O O O O 337 O O O O O O O O O 902 O O O O O O O* O * DC A: 0-200 μA direct measurement Fluke 337 Specifications Functions Range 333 Current AC 0-400.0A 2% ± 5 counts 0-600.0A 334 335 336 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts 0-999.9A Crest Factor 337 902 1% ± 5 counts 2% ± 5 counts 0-600.0A 2.4 @ 500A 3 @ 500A 2.0 @ 600A 2.5 @ 600A 0-999.9A 2.4 @ 500A 2.0 @ 600A 3 @ 500A 2.5 @ 600A 1.42@ 1000A Current DC True RMS Ordering Information Fluke 333 Fluke 334 Fluke 335 Fluke 336 Fluke 337 Fluke 902 Clamp Meter Clamp Meter True-RMS Clamp Meter True-RMS Clamp Meter True-RMS Clamp Meter True-RMS Clamp Meter (HVAC) 1% ± 5 counts 2% ± 5 counts 0-999.9A In-rush Current 2% ± 5 counts Integration time 100mS 100mS 100mS 100mS Voltage AC 0-600.0V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts Voltage DC 0-600.0V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts Resistance 0-600.0Ω 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 0-6000Ω 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts Included Accessories C33 Soft case, TL75 test leads, 80BK Integrated DMM temperature probe (902), 2 AA alkaline batteries, instruction card and safety information sheet. 0-200 μA 0-600.0A Fluke 902 0-9999Ω Continuity Frequency 1.5% ± 5 counts ≤ 30Ω ≤ 30Ω ≤ 30Ω 5-400Hz ≤ 30Ω ≤ 30Ω 0.5% ± 5 counts Temperature -10° to 400°C 1% ± 0.8°C Capacitance 1μF to 1000μF 1.9% ± 2 counts Battery Life: Alkaline, 150 hours Size (HxWxD): 238 mm x 79 mm x 41mm (333, 334, 335 and 902) 251 mm x 79 mm x 41 mm (336 and 337) Jaw Opening: 30 mm (333, 334, 335 and 902) 42 mm (336, 337) Weight: 0.312 kg Three Year Warranty Recommended Accessories H3 See page 119 26 ≤ 30Ω TL223 See page 110 L215 See page 111 320 Series Clamp Meters Big features, small package The Fluke 321 and 322 are designed to verify the presence of load current, ac voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meters are ideally suited for current measurements up to 400 A in tight cable compartments. Model 322 also offers DC voltage measurements and has a higher resolution for loads below 40 A. Features Functions Compact design Auto shut-off Display Hold Low battery indication Current AC Volts DC 321 O O O O O 322 O O O O O O Fluke 322 Specifications 321 Fluke 321 322 Functions Current AC Range 400.0A Resolution 0.1A Range 40.00A 400.0A Resolution 0.01A 0.1A Voltage AC 0-400.0V 400-600V 0.1V 1V 0-400.0Ω ≤ 30Ω 0.1Ω 0-400.0V 400-600V 0-400.0V 400-600V 0-400.0Ω ≤ 30Ω 0.1V 1V 0.1V 1V 0.1Ω Voltage DC Resistance Continuity Included Accessories C23 Soft carrying case, TL75 test leads, (2) AA alkaline batteries, coated instruction card, safety information sheet. Battery Life: 100 hours typical (2 AAA carbon zinc) Size (HxWxD): 190 mm x 63 mm x 35 mm Jaw Opening: 25 mm 321 322 Best Accuracy 1.8% ± 5 counts 1.8% ± 5 counts (50 - 60Hz) (50 -60Hz) 3.0% ± 5 counts 3.0% ± 5 counts (60Hz - 400Hz) (60Hz - 400Hz) 1.2% ± 5 counts 1.2% ± 5 counts (50-400Hz) (50-400Hz) 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts Weight: 0.23 kg Two Year Warranty Combo Kit Ordering Information Fluke 321 Fluke 322 Fluke 117/322 Kit Fluke 62/322/1AC Clamp Meter Clamp Meter Electricians Combo Kit IR Thermometer, Clamp Meter and Voltage Detector Kit Fluke 62/322/1AC Kit Fluke 117/322 Kit • Fluke 62 Infrared Thermometer • Fluke 322 Clamp Meter • Fluke 1AC II Volt Alert See page 4 Recommended Accessories H3 See page 119 TL223 See page 110 L215 See page 111 27 350 Series AC/DC Clamp Meters True-RMS, 2000 A Clamp Meters for industrial and utility applications Confidently take reliable readings with the true-rms, Fluke 353/355 Clamp Meters; the tools of choice for high current measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high current applications. The rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of protection when taking high-powered measurements. Accurate peak measurements can be taken using the in-rush current mode ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this the most versatile tool for utilities, electrical contractors and industrial service technicians. Features True-RMS measurements Display backlight Motor start-up current Min/Max/Average Voltage AC/DC Resistance measurement Continuity measurement with beeper Fluke 353 353 355 O O O O O O O O O O O Specifications (Check the Fluke web for detailed specifications) Fluke 355 Functions Current AC/DC Crest Factor Voltage AC/DC Resistance Continuity beeper Frequency True RMS Range 0-40.00 A 0-400.0 A 0-2000 A; 1400 AC rms 353 1.5% ± 15 counts 355 1.5% ± 15 counts 1.5% ± 5 counts 1.5% ± 5 counts 2.4 2.4 1% ± 10 counts 0-4.000 V 0-40.00 V 0-400.0 V 0-600 V AC rms 0-1000 V DC 0-400.0 Ω 0-4.000 kΩ 0-40.00 kΩ 0-400.0 kΩ Appr. ≤ 30 Ω 5.0Hz to 100.0Hz 100.1Hz to 999Hz 1% ± 5 counts 1.5% ± 5 counts 0.2% ± 2 counts 0.5% ± 5 counts Included Accessories Fluke 353: C43 Soft Meter Case, 6 AA batteries, users manual Fluke 355: C43 Soft Meter Case, 6 AA batteries, TL224 SureGrip® Silicone Test Lead Set, TP2 Slim Reach Test Probe Set (2 mm), AC285 SureGrip® Alligator Clip Set, users manual Power Supply: Battery Life: 6 x 1.5V AA NEDA 15A or IEC LR6 100 hours (with typical usage, backlight off) Size (HxWxD): 300 mm x 98 mm x 52 mm Jaw opening: 58 mm Weight: 0.814 kg Two year warranty Ordering information Fluke 353 Fluke 355 AC/DC Clamp Meter AC/DC Clamp Meter Recommended Accessories TL223 (Fluke 355) See page 110 28 L215 (Fluke 355) See page 111 360 Leakage Clamp Meter Leakage current measurements with a tough, pocket sized clamp meter The Fluke 360 is ideal for non-invasive checks of insulation resistance. The unique jaw design eliminates the influence of adjacent current conductors. The ergonomic design of the Fluke 360 ensures easy measuring. The measuring clamp fits into tight spaces and the wide display angle clearly shows the measurement result. The data hold button keeps the measured value on the display after removing the clamp for the measured conductor. The light Fluke 360 offers the widest range of current measurement for maintenance professionals and contractors. Features • Measurement of leakage protectives conductor and touch current with a resolution of 1μA • Advanced shielding to ensure accurate results when measuring near other conductors • Automatic ranging within the manually selected mA or A range • Easily viewed measurements on digital and bargraph display and HOLD when measuring in hard to see locations • Broad range of measurements currents up to 60 A for all installation needs • Easy carrying, pocket sized clamp with wide 40 mm jaw size • Display-Hold for convenience in use • Auto power off with audible warning buzzer • Conformance to IEC61010 and EMC standard • Meets all the applications and performance classes in safety standard VDE0404-4 and the new VDE0702 Fluke 360 Specifications (Check the Fluke web for detailed specifications) Functions Range 3mA 30mA 30A 60A 50 and 60Hz Current AC Frequency Resolution 0.001A 0.01mA 0.01A 0.1A Accuracy 1% ± 5 counts 1% ± 5 counts (0~50A) 5% ± 5 counts (50~60A) Battery type: 3 Volt Lithium, 90 hours typical Size (HxWxD): 176 mm x 70mm x 25 mm Weight: 0.2kg One Year warranty Included accessories Soft carrying pouch and users manual display: 1.7mA Ordering information Fluke 360 leakage current 0.5mA Leakage Clamp Meter ground leakage current 1.2mA (e.g. via motor shaft) 29 T100 Series Voltage and Continuity Testers The fast and easy solution to voltage, continuity and phase rotation testing The fast and easy solution to voltage, continuity and resistance measurements. Ideal for site conditions, the 3 models of the T100 Series 2-pole testers have a rugged construction and ergonomically formed housing for perfect handling. All models offer a patented three-phase rotation detection system providing quick phase rotation indication. Moreover they have a special electrical torch function for working in low light level environments and have an ingress protection rating of IP65. The T100 Series are compliant with EN 61010-1 and EN61243-3 requirements. Fluke T120 Features T100 Fluke T140 Fluke T100 Display Led Bargraph Backlight Resistance measurement Switchable load Voltage test Optical and acoustical continuity test Rotary field indication Single pole test for phase detection Indication of polarity Electrical torch function Probe tip protection The voltage display also functions when using discharged - or o batteries 12 LED’s T120 LCD 12 LED’s O O O O O O O O O O O O O O O O T140 LCD 12 LED’s O O O O O O O O O O O Specifications Included Accessories Two 1.5V batteries and instruction sheet Voltage AC/DC Continuity Frequency Phase rotation Resistance measurement Response time T100 12 - 690 V 0 - 400 kΩ 0 - 400 Hz 100 to 690 V < 0.1 s T120 12 - 690 V 0 - 400 kΩ 0 - 400 Hz 100 to 690 V < 0.1 s T140 12 - 690 V 0 - 400 kΩ 0 - 400 Hz 100 to 690 V Up to 1999 Ω < 0.1 s Ordering Information Fluke T100 Fluke T120 Fluke T140 Voltage/Continuity Tester Voltage/Continuity Tester Voltage/Continuity Tester Size (HxWxD): 240 mm x 56 mm x 24 mm Case: IP65 (water-jet and dust tight protection) Weight: 180 g Two year warranty UK versions are compliant with GS38 Recommended Accessories C33 (T100 Series) See page 118 30 T5 Electrical Testers The fast and easy solution to basic electrical testing The Fluke T5 testers let you check voltage, continuity and current with one compact tool. Select volts, ohms or current and the instrument does the rest. Model T5-600 measures 600 volts AC/DC, model T5-1000 is designed for 1000 volts. OpenJaw™ current technology lets you check current up to 100 A, without breaking the circuit. The optional H5 holster keeps the test probes and leads ready to test and lets you clip the T5 onto your belt. Features and Specifications Fluke T5-1000 Fluke T5-600 T5-600 1000 O O O 600 V 600 V 100 A 1000 Ω 600V CAT III Display Count Automatic Selection Continuity and Bleeper Sleep Mode AC Voltage DC Voltage AC Current Resistance Safety range Battery life: 400 hours Size (HxWxD): 203 mm x 51 mm x 30.5 mm Fluke T5-H5-1AC Kit Fluke T5-600/62/1ACII Kit T5-1000 1000 O O O 1000 V 1000 V 100 A 1000 Ω 1000 V CAT III / 600 V CAT IV Weight: 0.38 kg Two year warranty Fluke T5-H5-1AC Kit Fluke T5-600/62/1AC Kit The ideal kit for busy electrical contractors and electricians. The benefits of a voltage and current meter and noncontact voltage detector all in one kit. A holster for the T5 is also included. This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use elecrtrical test tools to find out more about the problem. Kit includes: - Fluke T5-1000 - H5 holster - Free Fluke 1AC-II Kit includes: • Fluke T5-600 • Fluke 62 • Fluke 1AC II • C115 Included Accessories TP4 4 mm detachable probes (detachable GS38 probes for the UK) and instruction sheet Ordering Information Fluke T5-600 Fluke T5-1000 Fluke T5-H5-1AC Kit Fluke T5-600/62/1AC Electrical Tester Electrical Tester Electrical Tester with holster and IAC Electrical Tester, IR Thermometer, Voltage Detector Kit Recommended Accessories H5 See page 119 ACC-T5-Kit See page 111 AC285 See page 112 31 1AC II Volt Alert LVD1/LVD2 Volt Lights SM100/200/300 SocketMaster-testers Fluke 1AC II VoltAlert™ Fluke 1AC II The Fluke VoltAlert AC voltage detector is very easy to use – just touch the tip to a terminal strip, outlet or cord. When the tip glows red and the unit beeps, you know there is voltage on the line. • It continually tests its battery and its circuit integrity with a periodic double flash visual indication. • Highest safety rating: CAT IV 1000 V • Detects voltage without metallic contact Operating range: 200 – 1000 V AC Batteries: Two AAA Alkaline Size (H): 148 mm Two Year Warranty Fluke 1AC II VoltAlert™ 5-pack • Buy 4 get 1 FREE LVD1 Volt Light Dual sensitivity voltage detector • Detects voltage from 40 V to 300 V AC • Blue light means you’re close • Red light means you’re at the source • Comes with a versatile clip to secure light to pocket, hat or even panel door LVD1 LVD2 Volt Light LVD2 Combines bright light and voltage detection in one pen style design • Dual sensitivity • Detects voltage from 90 V to 600 V AC • Blue light means you’re close • Red light means you’re at the source • Rated to CAT IV 600 V SM100/200/300 SocketMaster Testers The fast way to check if your sockets are safe. Ordering Information Fluke 1AC II Fluke 1AC II 5PK LVD1 LVD2 SM100 SM200 SM300 VoltAlert VoltAlert (5-pack) Volt Light Volt Light SocketMaster Tester SocketMaster Tester SocketMaster Tester SM100 SM200 SM300 Only available with UK plug Features Clear indication of wiring status Audible notification of wiring status Unique soft-touch RCD test checks 30 mA RCD´s for trip within 300 ms Earth Volts Touchpad detects raised earth voltages >50 V, indicating potentially dangerous situations 32 SM100 O SM200 O O SM300 O O O O 9040/9062 Phase Rotation Indicators Take the guess work out of phase/motor rotation measurements Fluke 9040 Fluke 9062 The Fluke 9040 is effective for measuring phase rotation in all areas where three-phase supplies are used to feed motors, drives and electrical systems. The Fluke 9040 is a rotary field indicator and can provide clear indication of the 3 phase via an LCD display and the phase rotation direction to determine correct connections. It allows rapid determination of phase sequence and has a voltage (up to 700 V) and frequency range suitable for commercial and industrial applications. Test probes supplied with the instrument have a variable clamping range for safe contact, especially in industrial sockets. The unique Fluke 9062 provides rotary field and motor rotation indication with the benefits of contact-less detection. Purpose made for commercial and industrial environments, the Fluke 9062 provides rapid indication of 3 phase rotation using test leads supplied or can be used to determine motor rotation on synchronous and asynchronous 3 phase motors. The contact-less detection is ideal for use on motors where the shaft is not visible. Test probes supplied with the instrument have a variable clamping range for safe contact, especially in industrial sockets. Fluke 9040 Features 9040 Via LCD O 3 phase indication Indication of phase rotation Indication of motor rotation direction Contact free determination of the rotation direction of running motors Clear LCD display No battery required 9062 Via LED O O O O O Fluke 9062 9040: Specifications 9062: Voltage range Phase display Frequency range Operating time Size (HxWxD) Fluke 9040: 124 mm x 61 mm x 27 mm Size (HxWxD) Fluke 9062: 124 mm x 61 mm x 27 mm 9040 40 - 700 V 15 - 400 Hz Continuous 9062 Up to 400 V 120 - 400 V AC 2-400 Hz Continuous Power supply 9040: from unit under test Power supply 9062: 1 x 9V Weight 9040: 0.20 kg Weight 9062: 0.15 kg Two Year Warranty Fluke 9062 Applications Included Accessories Fluke 9040: Alligator clips - black (3) Flexible test probes - black (3) Fluke 9062: Alligator clips - black (3) Flexible test probes - black (3) Test leads - black (3) Ordering Information Fluke 9040 Fluke 9062 Phase Rotation Indicator Motor and Phase Rotation Indicator Determine the presence of phase sequence of multiphase electrical supplies. Determine the rotation of running motors simply by placing the instrument on the motor casing. Check the correct rotation of motors prior to connection. Recommended Accessories TLK290 See page 111 TLK291 See page 111 C25 See page 118 33 2042 Cable Locator The multipurpose solution to cable location The Fluke 2042 is a professional general purpose cable locator. It is ideal for tracing cables in walls and underground, locating fuses/breakers on final circuits and locating interruptions and shortcircuits in cables and electrical floor heating systems. It can also be used for tracing metallic water and heating pipes. The unit is supplied as a complete kit comprising of a transmitter and receiver in a purposemade carry case. The receiver also incorporates a torch function for working in dimly lit locations. Transmitter Receiver Fluke 2042 • Receiver with a backlight LCD-display for level of receiving signal, code of receiving signal and live voltage indication • Automatic or manual adjustment of receiving signal sensitivity • Switchable acoustic receiving signal • Auto-Power-Off • Additional torch lamp function for working in dark environments • Additional transmitters are available for extension or to distinguish between several signals. • For all applications (live or dead cables) without additional instruments • Set includes a transmitter and a receiver • Proven digitally coded sender signal guarantees clear signal identification • Transmitter with LCD-display for transmitting level, transmitting code and external voltage Specifications Transmitter 12V, 50V,120V, 230V, 400V 0..60 Hz 125 kHz Up to 400V AC/DC Voltage Measurement Range Frequency Range Output signal Voltage Tracing depth cable location Receiver 0...2.5m wall/underground cables 0...0.4m Main voltage detection Batteries Transmitter: 6 pc Batteries 1.5V Batteries Receiver: 1 pc Battery 9V Size (HxWxD) Transmitter: 190 mm x 85 mm x 50 mm Size (HxWxD) Receiver: 250 mm x 65 mm x 45mm Weight Locator: 0.45 kg Weight Receiver: 0.36 kg Two Year Warranty Fluke 2042 applications Included Accessories TL27 Heavy Duty Test Lead Set (2) TP74 Lantern Tip Test Probe Set AC285 Alligator Clip Set Soft carrying case Hard case Ordering Information Fluke 2042 Fluke 2042T Cable Locator (transmitter + receiver) Cable Locator Transmitter Location of fuses/breakers and assignment to circuits Tracing of underground cables (max. depth 2.5 m) Precise location of cable interruptions with additional transmitter Recommended Accessories Fluke 2042T 34 Insulation Testers and Earth Ground Testers With a 5000 V MegOhmMeter for industrial-strength insulation testing and a range of compact hand-held instruments, we offer a solution for every troubleshooting and preventive maintenance application. Two of the digital hand-held insulation testers also include full-featured multimeters. The Fluke Earth Ground Testers can perform all four types of earth ground measurement, including stakeless testing with earth ground loop resistances using only clamps. 35 Insulation Tester Selection Guide InstallationTest Functionality Test voltages Insulation Resistance Test Range Polarization Index/Dielectric Absorption Ratio Auto Discharge Time Ramp test (Breakdown) Pass/Fail Comparison Estimated Number of Insulation resistance Tests Voltage > 30V Warning Memory Remote Test Probe Lo Ohms Display Continuity Multimeter Functionality AC/DC Volts Current Resistance Temperature (contact) Lo-Pass Filter Capacitance Diode Test Frequency MIN/MAX Other Hold/Lock Backlight 1577 1587 1587T 1503 1507 1550B 500V, 1000V 0.1MΩ - 600MΩ 50V, 100V, 250V, 500V, 1000V 0.01 MΩ - 2GΩ 50V, 100V 500V, 1000V 0.01MΩ - 100MΩ 0.1MΩ - 2GΩ O 50V, 100V, 250V, 500V, 1000V 0.01MΩ - 10GΩ O O 250V, 500V, 1000V, 2500V, 5000V 200KΩ - 1TΩ O O O O O O 1000 1000 1000 1000 O 1000 O O O O O O O O Digital LCD Digital LCD Digital LCD O O Digital LCD O O Digital LCD O O O (200mA) (200mA) O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O Battery 3 4 AA (NEDA 15A or IEC LR6) 3 4 AA (NEDA 15A or IEC LR6) 3 4 AA (NEDA 15A or IEC LR6) Digital LCD / Analog Bar Graph O O O O O Software Warranty (in years) O (99 locations) 1 4 AA (NEDA 15A or IEC LR6) 1 4 AA (NEDA 15A or IEC LR6) O (Fluke View® Forms Basic) 2 Rechargeable Buy a Fluke 1587 Combo Kit and save Fluke 1587/ET Advanced Electrical Troubleshooting Kit Fluke 1587/MDT Advanced Motor & Drive Troubleshooting Kit This kit contains: • Fluke 1587 Insulation Multimeter • Fluke 62 Mini Infrared Thermometer • i400 Current Clamp This kit contains: • Fluke 1587 Insulation Multimeter • Fluke 9040 Phase Rotation Indicator • i400 Current Clamp Perform insulation tests with the Fluke 1587 plus a wide-range of DMM tasks with confidence and ease. Use the i400 with your Fluke 1587 to accurately measure AC current without breaking the circuit. Check for hot spots and measure temperature with the Fluke 62 Mini non-contact thermometer. Perform insulation tests with the Fluke 1587 plus a wide-range of DMM tasks with confidence and ease. Use the i400 with your Fluke 1587 to accurately measure AC current without breaking the circuit. Check the phaserotation of three-phase motors easily and safely with the Fluke 9040. Fluke 1587/ET 36 Fluke 1587/MDT 1503/1507 Insulation Testers Truly portable insulation resistance testers When you need a low cost solution to general purpose insulation testing look no further than the new Fluke insulation tester range. The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable and easy to use. The multiple test voltages on both models make them ideal for many troubleshooting, commissioning and preventive maintenance applications. Additional features like the remote probe save both time and money when performing tests. Features 1503 O User selectable test voltages for many applications Additional test voltages 50V, 100V, 250V Special remote control probe for easy and safe measurements Auto-discharge of capacitive voltage for added user protection Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio Auto Power off to save batteries Large display with backlight Continuity function (200 mA) Compare function (pass/fail) for fast repetitive tests Fluke 1503 O O O 1507 O O O O O O O O O O O O O Fluke 1507 Specifications Insulation specifications Insulation test range Test voltages Test voltage accuracy Insulation test current AC/DC Voltage measurement Resistance measurement range Auto discharge 1503 0.1 MΩ to 2 GΩ 500 V, 1000 V + 20 %, - 0 % 1mA nominal 600 V (0.1 V resolution) 0.01 Ω to 20 kΩ Discharge time < 0.5 second for C = 1 μF or less Up to 1 μF > 4V ,< 8V > 200 mA Maximum capacitive load Open circuit test voltage Short circuit current Battery life: Insulation Test: > 1000 tests Size (HxWxD): 203 mm x 100 mm x 50 mm Weight: 0.55 kg One Year Warranty Fluke 1503/1507 Applications Included Accessories TP165x TL224 TP74 1507 0.01 MΩ to 10 GΩ 50 V, 100 V, 250 V, 500 V, 1000 V + 20 %, - 0 % 1mA nominal 600 V (0.1 V resolution) 0.01 Ω to 20 kΩ Discharge time < 0.5 second for C = 1 μF or less Up to 1 μF > 4V ,< 8V > 200 mA Remote Test Probe SureGrip Silicone Test Lead Set Lantern Tip Test Probe Set Alligator clips Ordering Information Fluke 1503 Fluke 1507 Insulation Tester Insulation Tester Insulation test at a distribution panel Wiring test in a small distribution box – all in one spot Recommended Accessories C101 See page 119 38 PAK See page 120 TLK 225 See page 111 AC285 See page 110 L210 See page 121 1577/1587 Insulation Multimeters Two powerful tools in one The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured True RMS digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventive maintenance. Whether you work on motors, generators, cables, or switch-gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks. The Fluke 1587T is specially designed for the telecom environment. Features Multimeter Features True RMS Voltage and Current for accurate measurements Digital display counts Autorange and manual range for easy testing. Selectable filter for accurate voltage and frequency measurements on motor drives Min Max Recording, Diode test, temperature, capacitance & frequency measurement for maximum flexibility. Fluke 1577 1577 O 6000 O Insulation features User selectable test voltages for many applications Additional test voltages 50V, 100V, 250V Special remote control probe for easy and safe measurements Auto-discharge of capacitive voltage for added user protection Live circuit detection prevents insulation test if voltage > 30V is detected for added user protection Fluke 1587 Fluke 1587T General features Auto Power off to save batteries Large display with backlight Input Alert to warn for incorrect connections Continuity 1587 O 6000 O O 1587T O 6000 O O O O O O O O O O O O O O O O O O O O O O O O O O O O Insulation Specifications Functions Measurement range Test voltages 1577 0.1MΩ to 600MΩ 500V, 1000V Test voltage accuracy Insulation test current Auto discharge + 20%, -0% 1mA nominal Discharge time < 0.5s for C = 1 μF or less Up to 1 μF load Maximum capacitive load 1587 0.01MΩ to 2GΩ 50V, 100V, 250V, 500V, 1000V + 20%, -0% 1 mA nominal Discharge time <0.5s for C = 1 μF or less Up to 1 μF load 1587T 0.01MΩ to 100MΩ 50V, 100V + 20%, -0 % 1 mA nominal Discharge time <0.5s for C = 1 μF or less Up to 1 μF load Multimeter Specifications Included Accessories C101 Rugged, utility hard case TL224 SureGrip Silicone Test Lead Set AC285 SureGrip Alligator Clip Set 80BK Integrated DMM Temperature Probe (Type K) TP165X Remote Test Probe Functions Voltage DC Voltage AC Current DC Current AC Resistance Capacitance Frequency Temperature Battery life: Maximum 1000V 1000V 400mA 400mA 50.0MΩ 9999μF 99.99kHz -40°C to +537°C Max. resolution 1 mV 0.1mV 0.01mA 0.01mA 0.1Ω 1 nF 0.01 Hz 0.1°C Meter: 1000 hrs, Insulation Test: >1000 tests 1577 ± (0.2% + 2) ± (2% + 3) ± (1.0% + 2) ± (2% + 2) ± (1.2% + 2) - 1587/1587T ± (0.09% + 2) ± (2% + 3) ± (0.2% + 2) ± (1.5% + 2) ± (0.9% + 2) ± (1.2% + 2) ± (0.1% + 1) ± (1% + 10) Weight: 0.55 kg Three Year Warranty Size (HxWxD): 203 mm x 100 mm x 50 mm Recommended Accessories Ordering Information Fluke 1577 Fluke 1587 Fluke 1587T Insulation Multimeter Insulation Multimeter Insulation Multimeter (for Telecom) C25 See page 118 i400 See page 114 TPAK See page 120 L215 See page 111 TL238 See page 110 37 1550B MegOhmMeter Digital insulation testing up to 5000 Volts The Fluke 1550B is a digital insulation tester capable of testing switchgear, motors, generators and cables at up to 5000 V DC. It can be used for a wide range of tests: from simple spot checks to timed tests and breakdown tests. Measurement storage and PC interface software make it ideal for preventive maintenance. • Test voltages of 250 V, 500 V, 1000 V, 2500 V, 5000 V • Capable of testing in 50 V increments between 250 V and 1000 V, and 100 V increments between 1000 V and 5000 V • Measures 0 to 1 Tera-Ohm • Warning voltage function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC • Guard system eliminates the effect of surface leakage current on highresistance measurements • Large digital/analog LCD shows detailed measurement data • Cable or insulation capacitance • Leakage current • Ramp function (0-5000 V DC) for breakdown testing • Timer 1 to 99 minutes • Polarization index and dielectric absorption calculated automatically • 99 memory locations store all measurements parameters • Includes Quicklink 1550B Software and Optical Interface cable Fluke 1550B Specifications Test Voltage (DC) 250V 500V 1000V 2500V 5000V Short circuit current Bar graph range Insulation test voltage accuracy Induced AC mains current rejection Charging rate for capacitive load Leakage current Capacitance measurements Live circuit indicator Timer increments; indicated to within 1 second Ramp Range 200kΩ to 5GΩ 5GΩ to 50GΩ 200kΩ to 10GΩ 10GΩ to 100GΩ 200kΩ to 20GΩ 20GΩ to 200GΩ 200kΩ to 50GΩ 50GΩ to 500GΩ 200kΩ to 100GΩ 100GΩ to 1TΩ greater than 1 mA and less than 2mA 0 to 1TΩ 0% to + 10% at 1mA load current 2 mA maximum 5 seconds per μF 1nA to 2mA 0.01μF to 15.00μF 30V to 600V AC/DC, 50/60Hz 1 to 99 minutes; settable in 1 minute 0% to 100% of selected test voltage, or until breakdown. Accuracy (+/- reading) 5% 20% 5% 20% 5% 20% 5% 20% 5% 20% ± (5% + 2nA) ± (15% rdg + 0.03μF) ± (5% + 2V) Included Accessories Test leads, 5000 V-rated probes, Alligator clips, Interface cable Flukeview Forms Basic, soft carrying case with water-proof bottom, instruction manual Ordering Information Fluke 1550B MegOhmMeter Operating Temperature: -20°C to 50°C Storage Temperature: -20°C to 65°C Relative humidity: 80% at 31°C, 50% at 50°C Dust/water resistance: IP40 Operating Altitude: 0 to 2,000 mtrs. Batteries: 12 volt, lead-acid, rechargeable Size (HxWxD): 170 mm x 242 mm x 330 mm Weight: 4 kg (with battery) Two Year Warranty FVF-SC2 See page 120 39 1620 Series Earth Ground Testers GEO Advanced technology for all your earth ground testing applications Fluke 1623 The new Fluke 1620 Series Earth Ground Testers not only measure ground resistance using the classic ‘fall of potential test’ but also enable time saving testing using the ‘selective’ and ‘stakeless’ methods. ‘Selective’ testing does not require the electrode under test to be disconnected during the measurement, thus increasing safety. The simple ‘stakeless’ method quickly checks ground connections using two current transformers (probes) clamped around the ground conductor under test. Offering ‘one-button’ simplicity, the 1623 is an all-in-one earth ground tester, while the 1625 has extra versatility for more demanding applications. Earth ground resistance and soil resistivity should be measured when: • Designing earth ground systems • Installing new ground system and electrical equipment • Periodically testing ground and lightning protection systems • Installing large electrical equipment such as transformers, switchgears, machines, etc. Features Fluke 1625 1623 O O O O One-button measurement concept 3- and 4-pole earth ground measurement 4-Pole soil resistivity testing 2-Pole resistance measurement AC 2-and 4-pole resistance measurement DC Selective testing, no disconnection of ground conductor (1 clamp) Stakeless testing, quick ground loop testing (2 clamps) Measuring frequency 128 Hz Earth impedance measurement at 55 Hz Automatic frequency control (AFC) (94 – 128 Hz) Measuring voltage switchable 20/48V Programmable limits, settings Continuity with buzzer Dust/water resistance Safety rating 1625 O O O O O O O O O IP56 CAT II 300 V O O O O O IP56 CAT II 300 V Specifications (Check the Fluke web for detailed specifications) Fluke 1625 kit Included accessories Fluke 1623: Protective holster, 2 test leads, 2 alligator clips, users manual Fluke 1623 Kit: same as above plus stake/reel Set 4 pole and selective/stakeless clamp set Fluke 1625: Protective holster, 2 test leads, 2 alligator clips, users manual Fluke 1625 Kit: same as above plus stake/reel set 4 pole and selective/stakeless clamp set Fluke 1623 Kit Fluke 1625 Fluke 1625 Kit 40 Basic GEO Earth Ground Tester Basic GEO Earth Ground Tester Kit Advanced GEO Earth Ground Tester Advanced GEO Earth Ground Tester Kit 1625 0 to 300 kΩ ± 5% 20 / 48 V 250 mA Battery type: 6 x AA alkaline cells Size (HxWxD): 110 mm x 180 mm x 240 mm Weight – 1623 Geo: 1.1 kg (including batteries) 1625 Geo: 1.1 kg (including batteries) Two Year Warranty Recommended Accessories Ordering information Fluke 1623 1623 0 to 20 kΩ ± 5% 48 V > 50mA Resistance ranges Operating error Test voltage Short circuit current EI-1623 EI-1625 Selective/stakeless clamp Selective/stakeless clamp set for 1623 set for 1625 ES-162P3 Stake/reel set for 3 pole measurements ES-162P4 Stake/reel set for 4 pole measurements EI-162BN 320mm Split core transformer for selective measurements on high voltage pylons 1621 Earth Ground Tester Handheld earth ground testing for mobile use The Fluke 1621 is an easy-to-use earth ground tester. The first line of defense in detecting reliable ground connections, the unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth tester, for most work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy tool for electrical contractors, utility test engineers, and earth ground specialists. Features • 3-pole Fall-of-Potential earth testing for basic measurements • 2-pole resistance measurements for added versatility • Easily capture values with single-button operation • Ensure accurate measurements with automatic ‘noise’ voltage detection • Hazardous voltage warning offers increased user protection • Clearly read and record data with a large, backlit display • Rugged holster and design for tough work environments • Portable size allows for easy transportation • Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting • Safety rating CAT II 600 V Fluke 1621 Specifications (Check the Fluke web for detailed specifications) 1621 0.15 Ω to 2 kΩ ± 6% of measured value + 5D ± 18% of measured value +5D 23 to 24 V AC > 50 mA AC Resistance range Basic accuracy Operating error according EN61557 Test voltage Short circuit current Battery type: 1 x 9 V alkaline (LR61) Size (HxWxD): 216 mm x 113 mm x 54 mm Weight: 0.850 kg Two Year Warranty Recommended Accessories Included accessories Two measuring leads with alligator clips 2 m, protective holster, users manual, CD-ROM Ordering information Fluke 1621 Earth Ground Tester GEO CABLE-REEL 25M Ground Earth Cable Reel 25 M Wire GEO CABLE-REEL 50M Ground Earth Cable Reel 50 M Wire GEO EARTH STAKE Ground Earth Stake ES-162P3 Stake/reel set for 3 pole measurements 41 1630 Earth Ground Clamp Meter Fast and easy earth ground loop testing The Fluke 1630 earth ground clamp meter simplifies ground loop testing and enables non-intrusive leakage current measurement. The ground loop testing is also known as “stakeless” earth ground testing. To carry out the measurement there is no need for placing earth stakes and disconnecting the earth system from the electrical installation. The Fluke 1630 combines the two current clamps needed to perform the stakeless ground loop test in one compact and easy to use instrument. • Ground loop resistance testing without any disconnection or additional earth stakes • Earth ground leakage current measurement for system troubleshooting • True RMS AC current measurement range up to 30 A • Rapid evaluation of continuity without disconnection and audible HI/LO alarm • Display-HOLD function to freeze measurements • Recording function for automatic storage of measured values, which can be recalled later on the LCD display • Automatic self calibration ensures correct measurement every time The Fluke 1630 is ideally suited for the following applications: • Ground loop checks on any earthing system • Continuity tests on earth bonding circuits and connections • Inspection of lightning protection systems • Leakage current measurement for troubleshooting on earth ground systems Specifications (Check the Fluke web for detailed specifications) Fluke 1630 Range 0.025 to 1500 Ω < app. 40 Ω 0.2 to 1000 mA 0.2 to 30 A Resistance Cntinuity buzzer Leakage current Current Max. resolution 0.002 Ω 0.001 mA 0.01 A Weight: 0.64 kg Conductor Size: 35 mm approx. Size (HxWxD): 257 mm x 100 mm x 47 mm Battery type: 9 V IEC 6 LR 61 Two Year Warranty Ground resistance measurements principle Ground resistance measurements principle Rg R1 R2 R3 .....Rn Equivalent circuit diagram Included Accessories Rugged carrying case with belt, Resistance test loop, 9 V battery, Operating instructions. R1 R2 Ordering Information Fluke 1630 Earth Ground Clamp Meter Rg Rg 42 .....Rn Installation Testers/ Portable Appliance Testers Our multifunction testers have redefined the standards for ease-of-use. Designed for ensuring fixed wiring is installed according to IEC 60364, they perform all tests required to verify safety. Our Portable Appliance Testers verify the safety and operation of portable appliances, and are designed for ‘one-touch’ operation and a fast throughput. 43 1650B Series Multifunction Installation Testers Extra functionality, faster testing, and as rugged as ever Fluke 1653B Fluke 1652B Safer, easier installation testing. The new 1650B Series builds on the rugged reputation of the earlier 1650 Series, only it’s re-designed to meet your need for more productive test tools. With new features like the fast, high current loop test (including a non-trip test) and a variable RCD trip current setting, accuracy is even better and the test cycle even faster. And with the addition of a unique zero adapter accessory for accurate mains test lead compensation, the 1650B Series continues to set the standard in installation testers. The 1650B Series testers verify the safety of electrical installations in domestic, commercial and industrial applications. They can ensure that fixed wiring is safe and correctly installed to meet the requirements of IEC 60364, HD 384 and BS 7671 17th Edition wiring regulations. 1653B - The complete tester for advanced users Fluke 1651B especially contractors, everyone who would want to have the best tool available and always understands (or know) how to use. 1652B - The ideal tester for professional trouble-shooters This is the instrument that is indeed ideal for professional users due to its additional functionality. It is also ideal since even though it has high-end features, it is still easy to use – even after longer periods of non-use; because operating it is intuitive and not forgotten easily. 1651B - The everyday tester, for every electrical installer This is the instrument that can be used every single day (day in, day out), and covers all the basic needs. It is the preferred tester for every front-line electrician/installer. This is the instrument that has it all, in a word: it’s complete. From all the test functions you need to in-built memory for documenting results. This makes it the complete solution for professionals, Features BS7671 17th Edition IEE Wiring Regulations IEC 60364.6.61, HD 384 Included Accessories 6 AA Cell batteries C1600 Hard carrying case Zero Adapter Mains test cord TL165X STD Standard Test Lead Set TL165/UK Fused Test Lead Set (UK only) Padded carrying strap Quick reference guide TP165X Remote control probe and lead 1 Users manual on CD-ROM 1653B O O O O O O O O O O O O O O O O O O O Zero adapter Volts (V) Frequency (Hz) Insulation (RISO) Continuity (RLO) Fast high current loop test (ZI) Loop test non trip mode (ZI) Short Circuit Current (PSC,PEFC, IK) RCD FI Trip TimeTest (FI, DDR) Variable RCD current setting Tests time-delayed RCD´s (S-type) RCD Ramp Test (FI, DDR) RCD Auto Test (FI, DDR) Test of pulse sensitive RCD´s Earth Resistance (RE) Phase Sequence Internal Memory IR Interface for downloading data Remote probe 1652B O O O O O O O O O O O O O O 1651B O O O O O O O O O O O O O* * Not in the UK 1 In the United Kingdom and Ireland: 1652B & 1653B only Ordering Information Fluke 1651B Multifunction Installation Tester Fluke 1652B Multifunction Installation Tester Fluke 1653B Multifunction Installation Tester Recommended Accessories See also page 48 for more details Check the Fluke website for the various software modules TLK290 Test Probe Kit 44 MTC1363 (UK) Mains Test Cord MTC77 (Europe) Mains Test Cord ES165X (1653) Earth Spike Test Kit FVF-SC2 (1653) See page 120 1650B Series Multifunction Installation Testers Extra functionality, faster testing, and as rugged as ever Specifications (Check the Fluke web for detailed specifications) AC Voltage Measurement Range Resolution Accuracy 50 Hz – 60 Hz ± (0.8% + 3 digits) Input Impedance Overload Protection 0.1 V 3.3 MΩ 660 Vrms Resolution Test Current Open Circuit Voltage Accuracy 0.01 Ω 0.1 Ω 1Ω > 200 mA > 4V ± (1.5%+3 digits) 500 V Continuity Testing Range (autoranging) 20 Ω 200 Ω 2000 Ω Slim probe design Thanks to its slim probe with integral test button, you can safely make one-handed measurements on hard to reach points, while keeping your eyes on the panel. This remote probe is powered by the tester so always operable (does not require additional batteries!). Zero Adapter For easy, always reliable and accurate compensation for test leads and mains cords. This adapter can be used for all different kind of mains plugs as well as test accessories like probes, alligator clips etc. Insulation Resistance Measurement Model Test Voltage Insulation Resistance Range 1653B 50 V 10 kΩ to 50 MΩ 1653B 100 V 20 MΩ to 100 MΩ 1653B 250 V 1652B 1651B 1653B 500 V 1652B 1651B 1653B 1000 V 1652B 1651B Loop Impedance Measurement Range 20 Ω 200 Ω 2000 Ω PFC. PSC Test Range Resolution and Units Accuracy 20 MΩ to 200 MΩ 20 MΩ 200 MΩ 500 MΩ 20 MΩ 200 MΩ 1000 MΩ Resolution Test Current Accuracy 0.01 MΩ 0.01 MΩ 0.1 MΩ 0.01 MΩ 0.1 MΩ 1 mA @ 50 kΩ 1 mA @ 100 kΩ ± (3%+ 3 digits) ± (3%+ 3 digits) 1 mA @ 250 kΩ ± (1.5%+ 3 digits) 0.01 MΩ 0.1 MΩ 1 MΩ 0.1 MΩ 1 MΩ 1 mA @ 500 kΩ ± (1.5%+ 3 digits) + 10% 1 mA @ 1 MΩ ± (1.5%+ 3 digits) + 10% Resolution 0.01 Ω 0.1 Ω 1Ω Accuracy No trip mode: ± (3% + 6 digits) Hi current mode: ± (2% + 4 digits) 1000A / 10kA(50kA) 1A / 0.1kA Determined by accuracy of loop resistance and mains voltage measurements Computation Prospective Earth Fault Current (PEFC) or Prospective Short Circuit Current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. RCD Testing RCD Type 1651B 1652B 1653B 1 O O O AC 2G O O O AC 3S 4 O O A G O O A S 1 4 AC – responds to AC 2G – General, no delay 3S – Time delay A - Responds to pulsed signal Tripping Time Test (ΔT) Current Settings Multiplier Test Current Accuracy Trip Time Accuracy 10, 30, 100, 300, 500, 1000 mA, VAR x 1/2 + 0% - 10% ± (1% Reading + 1 digit) 10, 30, 100 mA X5 + 10% - 0% ± (1% Reading + 1 digit) Tripping Current (Ramp) Test – Fluke 1653B and 1652B only Current Range Step size Dwell time 50% to 110% of 10% of I Δ N Type G Type S RCD’s rated current 300 ms/step 500 ms/step Earth Resistance Test (RE) – Fluke 1653B only Range 200 Ω 2000 Ω Complete kit All 1650B models are equipped with detachable leads that can be replaced in case of damage or loss. A durable hard case will protect your instrument in tough field conditions. Battery type: Alkaline supplied. usable with 1.2 V NiCD or NiMH rechargeable batteries Size (HxWxD): 100 mm x 250 mm x 125 mm Resolution 0.1 Ω 1Ω Trip Current Measurement Accuracy ± 5% Accuracy ± (2% + 5 digits) ± (3.5% + 10 digits) Weight: 1.17 kg Three Years Warranty 45 6000 Series PAT Testers Versatile PAT testing at your fingertips The Fluke 6200 and 6500 PAT testers verify the electrical safety and operation of portable appliances in accordance with relevant guidelines and regulations. With powerful auto test capabilities and simplified controls they increase the number of tests you can perform per day without compromizing results. Fluke 6200 Fluke 6500 A choice of automatic and manual PAT testers Both models perform all the tests required for class I and class II appliances. For manual testing and low volume applications, choose the costeffective 6200 PAT model. If you need a more powerful instrument to test large numbers of appliances, the 6500 is the right choice. Fluke simplifies portable appliance testing • Compact and lightweight… Efficient to work with and easy to carry around– and has extra space in the hard case for accessories. • One touch simplicity… Pre-set and user-definable test routines are initiated from a single button – to speed up test procedures and save you time on site. • A better way of working… Rapid data entry via a QWERTY keyboard (or optional Fluke barcode scanner) and fast data transfer from the main memory or the Compact Flash memory card (6500). 6200 6500 • Dedicated key for each test for ‘onetouch’ testing • Pre-set pass/fail levels to save time • Large backlit display for easy reading As 6200 but also with: • Integral QWERTY keyboard for rapid data entry • Slot for Compact Flash memory card for back-up data storage and transfer to PC • Pre-set, auto-test sequences for user convenience Also available with European mains socket. Features Included Accessories Test lead, Test probe, Crocodile clip, Mains cord Ordering Information Fluke 6200 Fluke 6500 PAT Tester PAT Tester Not available in all countries Measurement functions L N Mains Volts Outside Limits Indicators Null out facility for earth bond lead Protective Earth Resistance PE (200mA) Protective Earth Resistance PE (25A) Insulation 500V dc Protective Earth Conductor Current Touch Current Substitute Leakage Current Appliance Power kVA Appliance Load Current Seven Segment Custom LCD Graphical LCD Back Light Compact Flash Card receptacle Serial Port - Printing / Downloading O O 6500 O O O O O O O O O O O O O O O External printer output Front Panel QWERTY Key pad O O O IEC Lead Test Auto-testing Pass / Fail Level Programmable Indicators Data Storage Limited Data Storage Polarity Checks Graphical Help Menu On Line Programme Mode Real time clock O O O O O Front panel results management 230V BS1363 Test socket / 230V Mains BS1363 input power plug 46 6200 O O O O O O O O O O O O O O O O O O O O O 6000 Series PAT Testers Specifications The accuracy specification for the display range is defined as ± (%reading + digit counts) at 23 °C ± 5 °C, ≤ 75 % RH. Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C. The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997 , EN61557-4: 1997. Separate hard case The compact Fluke PAT testers are supplied with a hard carrying case that not only offers protection during transit but also includes extra storage space for accessories and other tools. They’re extremely light, weighing approximately 3 kg (without case) and have integral carrying handles for extra convenience. Power-on Test Touch Current Test The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency. Display Range 90 V to 264 V Display Range 0 to 1.99 mA ac Accuracy ± (4% + 2 counts) Resolution 0.01 mA Accuracy at 50 Hz ± (2% + 3 counts) Resolution 0.1V (1V - model 6200) Input Impedance > 1 MΩ // 2.2 μF Maximum Input Mains Voltage 300 V Internal Resistance (via probe) 2 kΩ Measuring method Probe The appliance under test is energized at mains potential. Substitute Leakage Current Test Display Range 0 to 19.99 mA ac Display Range 0 to 19.99 Ω Accuracy ± (5% + 5 counts) Accuracy (after Bond Test zeroing) Resolution ± (5% +4 counts) Resolution 0.01 mA Test Current Open Circuit Voltage 200 mA AC - 0% + 40% into 1.99Ω 25 A AC ± 20% into 25 mΩ at 230 V > 4 V AC, < 24 Vac Bond Test zeroing can subtract up to 1.99Ω Earth Bond Test 0.01Ω Test Voltage 35 V AC ± 20% Operational Error 10% Load/Leakage Test: Load Current Display Range 0 to 13 A Accuracy ± (4% + 2 counts) Resolution 0.1 A The appliance under test is energized at mains potential Insulation Test (Riso) Special PAT Kit If you need a complete PAT tester solution, a purpose made kit is available. Fluke 6500/UK Kit Contains: • 6500, Mainframe • EXTL 100, Extension lead test adaptor • SP Scan 15, Barcode scanner • Fluke PowerPat Plus • Pass 560R, Appliance pass labels • Fail 100S, Appliance fail labels APP 1000, Barcode appliance number labels Load/Leakage Test: Load Power Display Range 0 to 299 MΩ Accuracy Auto discharge time ± (5% + 2 counts) from 0.1 to 50 MΩ ± (10% + 2 counts) from 50 to 299 MΩ 0.01 MΩ (0 to 19.99 MΩ) 0.1 MΩ (20 to 199,9 MΩ) 1 MΩ (200 to 299 MΩ) 500 V DC - 0% + 25% at 500 kΩ load > 1 mA at 500 kΩ load, < 15 mA at 0 Ω < 0.5 s for 1 μF Max. Capacitive Load Operational up to 1 μF Resolution Test Voltage Test Current Display Range 0 to 999 VA 1.0 kVA to 3.2 kVA ± (5% + 3 counts) Accuracy Resolution 1 VA (0 to 999 VA) 0.1 kVA (1.0 kVA to 3.2 kVA) The appliance under test is energized at mains potential Load/Leakage Test: Leakage Current Display Range 0.25 to 19.99 mA Accuracy ± (4% + 4 counts) Resolution 0.01 mA The appliance under test is energized at mains potential (Kit contents may vary per country) PELV Test Accuracy at 50 Hz ± (2% + 3 counts) Overload protection 300 Vrms Warning threshold 25 Vrms Display Screens Size (HxWxD): 200 mm x 275 mm x 100 mm Weight: 3 kg Two Years Warranty Substitute Leakage Current Test Earth Bond Test (RPE) Recommended Accessories See also page 48 for more details Insulation Test (RISO) Touch Current Test Fluke PowerPat Plus software SP1000-02 Mini printer SP-SCAN-15 Barcode scanner (6500 Fluke only) BDST3 Snap Tags Cable Tie PASS Appliance 560R Pass Labels 47 1650B Series/6000 Series Accessories Accessories for Fluke 1650B Series Installation Testers Accessories for Fluke 6500 Series Portable Appliance Testers PASS560R Appliance Pass Labels ES165X Earth Spike Test Kit (Fluke 1653B) Quantity 500 SP1000 Mini Printer Without using any additional software the SP1000 can be used to directly printout stored test records on to thermal paper. The printer is compact and easily transported and is ideal for test professionals who need to issue an immediate written account of work carried out. The printer is powered by a rechargeable battery and comes complete with mains charger and RS232 Printer Lead. Earth Spike Test kit contents: • Auxiliary earth probes • Test connection leads and crocodile clips • Purpose-made carry case APP1000/APP2000 Bar Code Appliance Number Labels APP1000: Labels numbered 0001-1000 APP2000: Labels numbers 1001-2000 Label number >2000 on request FVF-SC2 Fluke ViewForms Software (Fluke 1653B) To address the increasing demands for reporting and documentation, Fluke presents FlukeView Forms documenting software. Download the data from the Fluke 1653B and create an easy report. The Fluke ViewForms Software also supports other Fluke tools. See page 120. Replacement thermal paper for the SP1000 Mini Printer Fluke DMS software for 1650B/6000 Series BDST3/BDST4 Snap Tags BDST3: Cable Tie BDST4: Clip On Quantity 20. Without labels. TLK 290 Test Probe Kit • Kit includes three flexible socket probes and a large alligator clip • To be used on three phase sockets • Probes have flexible width test points that fit securely in 4 to 8 mm sockets • CAT III 1000 V, 8 A SP1000 Paper EXTL100-02 (UK plug) EXTL100-02 (Schuko plug) EXTL100 Extension Lead Test Adaptor Adaptor for testing extension leads. Allows the earth test lead to be connected to the extension leads to perform insulation and earth bond tests. The Fluke DMS (Data Management Software) is an efficient program for administration and reporting of installation tests in compliance with EN 60364, DIN VDE 0100/0105, BS7671 17th edition wiring resulation and appliance tests in compliance with DIN VDE 0701/0702, ÖVE E 8701. DMS 0100/INST Software for Installation Tester Fluke 1653B Supporting reports for Austria, Germany, UK, Switzerland, Netherlands DMS 0702/PAT Software for Portable Appliance Tester Fluke 6500 Supporting reports for Austria, Germany, UK, Netherlands DMS COMPL PROF Software for the Fluke 1653B and Fluke 6500 Supporting reports for Austria, Germany, UK, Switzerland, Netherlands MTC1363 MTC77 Mains Test Cord for 1650B series MTC1363 MTC77 48 UK plug Schuko plug SPScan15 Barcode Scanner Easy to use, low current, intelligent barcode reader. SPScan15 can be used to scan barcodes attached to curved surfaces or where actual contact with the barcode surface is difficult. Check the Fluke web for more information. Digital Thermometers For troubleshooting systems where temperature is a critical symptom, our digital thermometers provide you with laboratory accuracy wherever you need it. We offer a choice of non-contact, laser-guided infrared thermometers for safely getting at hard-to-reach, electrically live or particularly hot targets, and contact thermometers with a full range of thermocouple probes. 49 See catalog page Data logging (number of measurements) PC interface Compatible with FlukeView Forms software Adjustable emissivity MIN/MAX readings AVG readings DIF readings Backlit LCD Bar graph display Audible Hi/Lo alarm Visible Hi/Lo alarm Includes contact probe Probe input (types) Laser sighting Close focus model available Recommended distance to spot Contact thermometers For our complete range of contact thermometers, see page 55. 50 Temperature range Accuracy Response time Optical resolution Infrared Thermometer Selection Guide 52 O -/O single-point laser Up to 2 m Fluke 62 -30 to 500 ºC 1.5% < 500 mSec 10:1 52 O -/O single-poimt laser Up to 2.5 m RTD RTD 52 52 12 points O O O O 12 points single-point laser O O O O O Up to 7.5 m Fluke 68 - 32 to 760 ºC 1% < 500 mSec 50:1 single-point laser O O O O O Up to 4.5 m Fluke 66 - 32 to 600 ºC 1% < 500 mSec 30:1 Heating/ventilation/air conditioning/ refrigeration Leaky ductwork Thermostats Temperature balancing Steam distribution systems Compressor lines Fluke 60 Series Fluke 63 - 32 to 535 ºC 1% < 500 mSec 12:1 Plant/facilities maintenance Preventive and predictive maintenance Energy audits Vehicle and fleet maintenance programs Faulty electrical/circuit connections Petrochemical/hazardous locations Motors, pumps and bearings 52 O single-point laser Up to 2 m Fluke 61 -18 to 275 ºC 2% < 500 mSec 8:1 53 20 points O O O Type K Thermocouple single-point laser O O O O O Up to 4.5 m Fluke 560 Series Fluke 566 - 40 to 650 ºC 1% < 500 mSec 30:1 O Safety and protection Fire localization Hazardous materials Faulty ballasts Search and rescue Smoldering embers Equipment maintenance Recommended Applications 51 RS232 O 53 100 points 300 mm (with close focus) up to 10.5 m 3-point laser O O O O O O O O O Type K Thermocouple USB 51 O O O/O/- 300 mm (with close focus) up to 10.5 m 3-point laser O O Fluke 570 Series Fluke 572 Fluke 574 - 30 to 900 ºC - 30 to 900 ºC 0.75% 0.75% < 250 mSec < 250 mSec 60:1 (50:1 60:1 (50:1 with close with close focus) focus) O O 99 points O O O Type K Thermocouple single-point laser O O O O O Up to 7.5 m Fluke 568 - 40 to 800 ºC 1% < 500 mSec 50:1 Manufacturing processes Molding temperature measurement Printing, paper and converting Thermoforming plastics Electronics Paint curing/drying Food Chemical and pharmaceutical 54 O Type K Thermocouple O O single-point laser O O Up to 2.5 m Fluke 561 - 40 to 550 ºC 1% < 500 mSec 12:1 Infrared Thermometer Selection Guide 570 Series Precision Infrared Thermometers Measure temperature with ease and precision The Fluke 570 series are the most advanced IR non-contact thermometers, and are ideal for predictive and preventative maintenance applications. Offering a broad temperature range and a true dimension laser sighting system for precise targeting resulting in more accurate measurements. When requiring analysis and documentation use the 100-point data logging and software for graphing and analysis. From close-up electrical connections, to far-distance room balancing checks, the Fluke 570 series can take IR temperature measurements with ease and precision. • Enhanced optics allows measurements of smaller objects from farther away • True Dimension™ three-dot laser sighting system highlights the true diameter of measurement spots at all distances • Adjustable emissivity setting and 30 pre-set common material values for more accurate measurements • 100 data point memory for storage of measurements (Fluke 574). Fluke 574 Features 572 Temperature range Optical resolution 574 -30 to 900ºC Standard: 60:1 Close focus: 50:1 3 dot laser beam for accurate targeting Adjustable emissivity Bar graph display Backlit LCD display Use selectable ºC or ºF Audible and visible Hi/Lo Alarm MIN/MAX AVG/DIF readings Datalogging (number of measurements) PC interface O O O O O O/O O O O O O O/O O O 100 RS232 Specifications 572 Fluke 572 Included Accessories Fluke 572: Hard case, 2 batteries Fluke 574: Hard case, 2 batteries, Thermocouple K probe, 220V power supply, IRGraph software, RS232 cable Ordering Information Fluke 572 Precision Infrared Thermometer Fluke 574 Precision Infrared Thermometer Fluke 572CF Precision Infrared Thermometer with close focus option Fluke 574CF Precision Infrared Thermometer with close focus option Temperature range Response time Resolution Repeatability Accuracy: (assumes ambient operating temperature of 23 ºC to 25 ºC ) Typical distance to target Emissivity 574 -30 to 900°C 250ms (95 % of reading) 0.1°C of reading up to 900°C ±0.5% of reading or ±1°C* ±0.75% of reading, ±0.75°C * 10,5 m Digitally adjustable from 0.10 to 1.0 by 0.01 *whichever is greater. Battery Life: 10 hours typical Weight: 0.480 kg Size (HxWxD): 200 mm x 170 mm x 55 mm Two years warranty Recommended Accessories AN5 Analog data cable C570 See page 118 51 60 Series Infrared Thermometers Point, press and read temperature The 60 Series IR thermometers feature: The Fluke 60 Series non-contact thermometers are the ideal professional diagnostic tools for quick and accurate temperature measurements. These handheld tools are ideal for measuring surface temperatures of rotating, hard-to-reach, electricity live or dangerously hot targets like electrical motors and – panels, and heating and ventilation systems. The laser sighting system guides measurements to the right target and in less than a second, the large temperature display provides a readout of the surface temperature. Fluke 68 Fluke 66 • Laser guided sighting system for easy targeting with 1% accuracy • Up to 12 points datalogging with Min/ Max/Average functions • Up to 50:1 optical resolution • Choice between models with fixed or adjustable emissivity • Backlit display for easy reading in the dark • Temperatures up to 760°C Features 61 62 63 66 68 Flat grip Pistol grip Pistol grip Pistol grip Pistol grip Temperature range -18 to 275°C -30 to 500 °C -32 to 535°C -32 to 600°C -32 to 760°C Optical resolution 8:1 10:1 12:1 30:1 50:1 Laser beam for accurate targeting O O O O O O O O O Max Max O O O O O O O O O O O O O O Form factor Fluke 63 Fluke 62 Backlit LCD display Use selectable °C or °F Min/max/avg/dif readings Datalogging Hi/Lo Alarm Adjustable emissivity Specifications Range Response time Resolution Repeatability (% of reading) Accuracy: Fluke 61 The Fluke FoodPro™ thermometer series provide advanced temperature measurement solutions for the foodservice industry. Check the Fluke web for more information. 61 62 63 66 68 - 18 to 275ºC - 30 to 275 ºC - 32 to 535 ºC - 32 to 600 ºC - 32 to 760 ºC < 500ms < 500ms (95 % of reading) 0.2 ºC ≤ 0.5 second ≤ 0.5 second ≤ 0.5 second 0.2 ºC 0.2 ºC 0.1 ºC 0.1 ºC ± 2% or ± 2 ºC* For targets at: ± 0.5% or < ± 1 ºC* For targets at: ± 0.5% or ≤ ± 1 ºC* For targets at: ± 0.5% or ≤ ± 1 ºC* For targets at: ± 0.5% or ≤ ± 1 ºC* For targets at: (assumes ambient operating temperature of 23ºC) -18 to -1ºC: ± 3ºC -1 to 275ºC: ± 2% of reading or ± 2ºC 10 °C to 30 °C: ±1 °C ± 1.5% of reading or ± 1.5°C whichever is greater over the balance of the range -32 to -26°C: ± 3°C -26 to -18°C: ± 2.5°C -18 to 23°C: ± 2°C 23°C -510°C: ± 1% of reading or ± 1°C* For targets above 510°C: ± 1.5% of reading -32 to -26°C: ± 3°C -26 to -18°C: ± 2.5°C -18 to 23°C: ± 2°C For targets above 23 ºC: ± 1% of reading or ± 1 ºC* -32 to -26°C: ± 3°C -26 to -18°C: ± 2.5°C -18 to 23°C: ± 2°C For targets above 23 ºC: ± 1% of reading or ± 1 ºC* Typical distance to target Emissivity Up to 1m Up to 1.5 m Up to 2 m 5m 8m Fixed at 0.95 Pre-set to 0.95 Fixed at 0.95 Digitally adjustable from 0.1 to 1.0 by 0.01 Digitally adjustable from 0.1 to 1.0 by 0.01 * whichever is greater Included Accessories Fluke 61: 9V Battery Fluke 62: 9V Battery, storage holster Fluke 63, 66 and 68: Hard carrying case, 9V batteries Battery Life: Fluke 66 and 68: Fluke 63: Fluke 62: Fluke 61: 20 hours with laser and backlight on 50% 10 hours with laser and backlight on 12 hours with laser and backlight on 12 hours with laser and backlight on Size (HxWxD): Fluke 63, 66 and 68: Fluke 62: Fluke 61: 200 mm x 160 mm x 55 mm 152 mm x 101 mm x 38 mm 184 mm x 45 mm x 38 mm Weight: Fluke 63, 66 and 68: Fluke 62: 0.200 kg Fluke 61: 0.227 kg 0.320 kg Fluke 62: 2 years warranty Other models: one year warranty Ordering information Fluke 61 Infrared Thermometer Fluke 62 Mini Infrared Thermometer Fluke 63 Infrared Thermometer Fluke 66 Infrared Thermometer Fluke 68 Infrared Thermometer Fluke 62/322/1AC (see page 5) Fluke T5-600/62/1AC (see page 5) Kits Recommended Accessories C23 See page 118 52 Fluke 62/322 kit T5-600/62/1AC 80PR-60 See page 117 H6 See page 119 566 and 568 Multipurpose Thermometers The two-in-one infrared and contact thermometer with an innovative graphical display With a straight-forward, menu-driven user interface and graphical display, the Fluke 566 and 568 multipurpose thermometers make even complex temperature measurements easy. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button. For added convenience, both rugged handheld thermometers combine contact and non-contact temperature measurement capability, providing a total temperature measurement solution for any service and maintenance program. Fluke 566 • Easily access advanced features with the soft-key buttons and graphical display • Measure smaller targets from farther away using the IR thermometer • Adjustable emissivity and built-in table of common materials for higher IR accuracy • Quickly identify problems with the MIN, MAX, AVG, and DIF functions • 2-color flashing alarm alerts you visually when measurements exceed limits • Includes Type K thermocouple bead probe • Compatible with all standard miniconnector K-type thermocouples • Data logging with a date/time stamp • Soft rubber boot for increased ruggedness • User interface available in 6 languages Fluke 568 Choose your language Select the measurement surface See complete measurement details in seconds Specifications (Check the Fluke web for detailed specifications) Infrared temperature range Infrared accuracy The Fluke 566 and included accessories Display resolution Infrared spectral response Infrared response time Input temperature range Input accuracy D:S (Distance to measurement spot size) Laser sighting Minimum spot size Emissivity adjustment Data logging with Date/Time stamp PC interface and cable Hi/Low alarms Min/Max/Avg/Dif Display Backlight Trigger Lock Switchable between Celsius and Fahrenheit The Fluke 568 and included accessories Included accessories 566 568 -40 °C to 650 °C -40 °C to 800 °C < 0 °C : ± (1.0 °C + 0.1°/1 °C); > 0 °C : ± 1 % or ± 1.0 °C, whichever is greater 0.1 °C 8 μm to 14 μm < 500 msec -270 °C to 1372 °C -270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C) -40 °C to 1372 °C: ± 1 % or 1 °C, whichever is greater 30:1 50:1 Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm 19 mm By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 20 points 99 points None USB 2.0 with FlukeView® Forms software Audible and two-color visual Yes Dot matrix 98 x 96 pixels with function menus Two levels, normal and extra bright for darker environments Yes Yes Power: 2 AA/LR6 Batteries (566); 2 AA/LR6 Batteries and USB for use with a PC (568) Battery life: Used continuously; laser and backlight on: 12 hours; laser and backlight off: 100 hours FlukeView® Forms software (568 only), USB cable (568 only), K-type thermocouple bead probe, 2 AA batteries, hard carrying case, quick start guide, and users manual. Weight: 0.965 kg (566); 1.026 kg (568) Size (HxLxW): 25.4 cm x 19.1 cm x 6.9 cm Operating temperature: 0 °C to 50 °C Storage temperature: -20 °C to 60 °C Two years warranty Recommended Accessories Ordering information Fluke 566 Fluke 568 Infrared thermometer Infrared thermometer H6 See page 119 80PK-8 See page 116 80PK-9 See page 116 80PK-11 See page 116 80PK-25 See page 116 80PK-26 See page 116 53 561 Multipurpose Thermometer Combined Infrared and Contact Thermometer Fluke 561 The Fluke 561 combines the temperature measurement functions that industrial, electrical, and HVAC/R professionals need, all in one tool. It measures both IR and contact temperature, replacing several other test tools. It’s fast, efficient, and easy to use, saving you valuable time and effort. With the Fluke 561, you can take contact and ambient temperatures in the way that’s best for you. Use the IR thermometer to measure hot, moving, electrically energized, and hard-toreach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor—leave your ladder in the truck. You can use the Fluke 561’s handy Velcro® pipe probe or, plug in any industry standard, K-type mini-connector thermocouple probe you already own. • IR thermometer for quick measurements up close or at a distance • Single-point laser sighting • Easy emissivity adjustment for measuring pipes and ducts more accurately • Includes a Velcro pipe probe for superheat and sub-cooling as well as other surface contact measurements • Also compatible with all standard miniconnector K-type thermocouples • MIN, MAX and DIF temperature readings • Lightweight (only 340 grams) and portable • Includes measurement guide Specifications The Fluke 561 includes everything you need for immediate inspections. Temperature range Display resolution D:S (Distance to spot size) Easy emissivity selector Display accuracy (Assumes ambient operating temperature of 23° to 25°C) Response time Repeatability Spectral focus Laser sighting Laser shutoff Laser power Relative humidity Power Display hold Backlit display Operating temperature Storage temperature MAX, MIN, DIF temperatures Thermocouple type K mini-adapter input Thermocouple type K Velcro pipe probe Measurement guide -40° to 550°C 0.1° of reading 12:1 Adjustable with three settings: low (0.3), medium (0.7), high (0.95) ± 1.0% of reading or ± 1°C, whichever is greater; below 0°C, ± 1°C, ± 1°/1° 500 mSec (95% or reading) ± 0.5% of reading or ± 1°C, whichever is greater 8 μm to 14 μm Single-point laser Laser turns off above ambient temperature of 40°C Class 2 (II) operation; output ‹ 1 mW, wavelength 630 nm to 670 nm 10% to 90% RH non-condensing, at < 30°C 2 AA batteries (alkaline or NiCD) 7 seconds Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options 0° to 50°C -20 to 65°C Yes Yes, compatible with industry standard type K probes with mini-connector Yes, with a temperature range of 0° to 100°C and accuracy of ± 2.2°C Yes Battery Life (alkaline): 12 hours Weight: 340 grams Size (HxLxW): 176,9 mm x 163,6 mm x 51,8 mm Two years warranty Included accessories Thermocouple K-type Velcro pipe probe, hand carrying case, 2 AA batteries and user manual with measurement guide. Recommended Accessories Ordering information Fluke 561 HVACPro Thermometer H6 Se page 119 54 80-PK-1 See page 116 80PK-8 See page 116 80PK-25 See page 116 50 Series II Thermometers Laboratory accuracy. Wherever you go. Additional features for the 53 and 54 Series II: The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged handheld test tool. • Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only) plus MIN, MAX, or AVG • Relative time clock on MIN, MAX, and AVG provides a time reference for major events • Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy • Readout in °C, °F, or Kelvin (K) • Sleep mode increases battery life • Battery door allows easy battery replacement without breaking the calibration seal • Data Logging up to 500 points of data with user adjustable recording interval • Real time clock captures the exact time of day when events occur • Recall function allows logged data to be easily reviewed on the meter display • IR communication port allows data to be exported to optional FlukeView® Temperature PC software Features Thermocouple types Number of inputs Time stamp Splash/Dust resistant Dual display with backlight Min/Max/Avg recording (T1-T2) True differential Data logging up to 500 points IR data port for interface to PC Compatible with optional FlukeView Software Fluke 54 II 51 II J,K,T,E Single Relative Time O O O 52 II J,K,T,E Dual Relative Time O O O O 53 II J,K,T,E,N,R,S Single Time of Day O O O O O 54 II J,K,T,E,N,R,S Dual Time of Day O O O O O O O O Specifications Fluke 51 II Fluke 52 II Fluke 53 II Included Accessories Impact absorbing holster Two bead probe thermocouples 80PK-1 (54+52) One bead probe thermocouple 80PK-1 (51+53) Ordering Information Fluke 51 II Fluke 52 II Fluke 53 II Fluke 54 II FVF-SC1 Thermometer Thermometer Thermometer Thermometer FlukeView Forms Software including interface cable Temperature range: J-type Thermocouples K-type Thermocouples T-type Thermocouples E-type Thermocouples N-type** Thermocouples R** and S-type** Thermocouples Temperature accuracy Above –100°C (-148°F): J, K, T, E, and N-type** R** and S-type** Below –100°C (-148°F): J, K, E, and N-types T-type -210°C to 1200°C -200°C to 1372°C -250°C to 400°C -150°C to 1000°C -200°C to 1300°C 0°C to 1767°C ± [ 0.05% + 0.3°C ] ± [ 0.05% + 0.4°C ] ± [ 0.20% + 0.3°C ] ± [ 0.50% + 0.3°C ] **Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type Battery life: 1000 hours typical, AA Size (HxWxD): 173 x 86 x 38 mm Weight: 0.4 kg Three Year Warranty Recommended Accessories C25 See page 118 80PK-26 See page 116 80PK-25 See page 116 FVF-SC1 See page 120 TPAK See page 120 55 1523 and 1524 Reference Thermometers A new standard in accuracy and versatility. Measure, graph and record three sensor types with one tool. The Fluke 1523/24 Reference Thermometer deliver high accuracy, wide measurement range, logging, and trending, all in a handheld tool you can take anywhere. For top accuracy, a memory chip inside the probe connector feeds probe calibration information to the readout. In addition, any thermocouple with a mini-thermocouple connector can be read using the optional universal thermocouple adapter. Choose the 1523 for single channel or the 1524 for dual channel measurement. Three sensor types Fluke 1524 Fluke 1523 • PRTs: –200 °C to 1000 °C • Thermocouples –200 °C to 2315 °C • Precision thermistors: –50 °C to 150 °C High accuracy • PRTs: ±0.011 °C • Thermocouples: ±0.24 °C for J,K,L,M • Precision thermistors: ±0.002 °C Fast measurement • PRTs: up to 0.45 seconds/sample • Thermocouples: up to 0.3 seconds/ sample • Precision thermistors: up to 0.3 seconds/sample Two models • 1523: Single channel standard model; memory for 25 readings & statistics • 1524: Two channels; memory for 25 readings and statistics plus logging 15,000 measurements; real-time clock for time and date stamps Features Note: The 1523/24 are pictured with probes connected which may be purchased seperately. Included Accessories NIST traceable certificate of calibration, users guide, CD-ROM (contains technical manual), 12 V dc universal power supply, RS-232 cable, 9940 I/O ToolKit software Sensor Types Thermocouple Types Number of inputs Data trending (graphing) Graphical display with backlight Min/Max/Avg/Standard deviation recording High speed measurement RS-232 PC communications T1-T2 True differential Data logging up to 15,000 points Time and date stamp 1523 1524 PRT & RTD, Thermistor, and Thermocouple B,C,E,J,K,L,M,N,R,S,T,U Single Dual O O O O O O O O O O O O O Ordering Information Fluke 1523* Reference Thermometer Fluke 1524* Reference Thermometer Fluke 1523-P1 Reference Thermometer, PRT(–200 °C to 420 °C, 6.35 mm x 298 mm), Universal Thermocouple Adapter, TPAK, and Case Fluke 1524-P1 Reference Thermometer, PRT(–200 °C to 420 °C, 6.35 mm x 298 mm), Universal Thermocouple Adapter, TPAK, and Case * Requires an optional probe Specifications (Check the Fluke web for detailed specifications) Temperature range Thermocouple PRT & RTD Thermistor Resolution and best accuracy Thermocouple PRT & RTD Thermistor Operating temperature Storage temperature –200 °C to 2315 °C –200 °C to 1000 °C –50 °C to 150 °C 0.01 °, ±0.24 °C 0.001 °, ±0.011 °C 0.001 °, ±0.002 °C –10 °C to 60 °C –20 °C to 70 °C Optional Accessories 2384-P 2384-T 2373-LPRT INFO-CON Connector, PRT (Gray Cap), Spare INFO-CON Connector, Thermocouple (Blue Cap), Spare RTD Adapter, Lemo to Mini Grabbers (4-wire) Battery life (alkaline): 20 hours Power supply: Universal 12 Vdc Size (HxWxD): 200 x 96 x 47 mm Weight: 0.65 kg Warranty: 1 year Recommended Accessories Optional probes: 5616-12-P 5615-9-P 5610-9-P 56 PRT, 6.35 mm x 298 mm, –200 °C to 420 °C PRT, 4.76 mm x 229 mm, –200 °C to 420 °C Thermistor, 3.2 mm x 229 mm, 0 °C to 100 °C TPAK FLK80P1 (80PK1 with universal thermocouple adapter) FLK80P3 (80PK-3A with universal thermocouple adapter) 2384P and 2384T Spare INFO-CON Adapters 2373-LTC Universal TC adapter Thermal Imagers Temperature changes can indicate problems in many everyday applications and a thermal imager makes it quick and easy to visually check surface temperatures. Often problems can be discovered before contact measurements even need to be made. Fluke offers a complete range of handheld thermal imagers for both industrial and building diagnostic applications. Models are available for any budget. 57 Ti Series Thermal Imagers Find it, fix it, fast! Temperature changes can indicate problems in many areas you see everyday, some include: • Inside electrical distribution and service (Switch gear, panels, controls, fuses,transformers, receptacles, lighting, conductors, bus bars, motor control centers) • Motors, pumps and mechanical (Electric motors and generators, pumps, compressors, evaporators, bearings, couplings, gearboxes, gaskets/seals, belts, rollers, disconnects) • Process (Tanks and vessels, pipes, valves and traps, reactors, process insulation) • HVAC/R (air conditioning, heating, air handlers, refrigeration) • Outside electrical distribution - utilities (Transformers, bushings, insulators, transmission lines, other exterior conductors, service connections, disconnects, capacitor banks) IR-Fusion® Technology: Infrared and visual images fused together in one image See things both ways - Infrared and visual (visible light) images fused together communicating critical information faster and easier – traditional infrared images are no longer enough. Patented IR-Fusion® Technology, only available from Fluke, simultaneously captures a digital photo and the infrared image and fuses them together taking the mystery out of IR image analysis. Full IR Picture-in-Picture IR/Visible Alarm Full Visible Light Alpha Blending www.fluke.eu/ti Overheating bearing cap Three-phase switch-gear load imbalance SmartView® Software Overheated motor Cool corner in a building Fluke SmartView® software is included with each Fluke Thermal Imager. This powerful software is a modular suite of tools that annotates, views, edits and analyzes IR images. It also generates fully customizable and professionallooking reports in a few easy steps. The IR-Fusion technology is fully supported. Thermal imaging application video This video covers the principles of thermal imaging and looks at using this powerful troubleshooting technology in electrical, electro-mechanical and process control applications. Go to www.fluke.co.uk/ti or www.fluke.eu/ti to see the video. FREE webinars/webcasts on Thermal Imaging Keep up-to-date on the latest troubleshooting techniques. Attend a FREE Fluke webinar (web-based seminar) about thermal imaging applications. Go to www.fluke.eu/ti for more information. 58 CRange IRWindows Increase the safety and speed of electrical thermography Infrared windows mount into panel doors and covers for switchgear, transformers, bus bars and other live electrical equipment, allowing Infrared, Ultraviolet, Visual and IRfusion technologies to be used without exposing personnel to live equipment. All infrared windows from Fluke use the unique Quadraband™ multispectral optic, allowing inspection with any camera for total flexibility both now and in the future. • Reduce the arc flash risk associated with electrical thermography • Increase efficiency as thermographer can work alone without being accompanied by an electrician to isolate and open panels • Stay safety compliant with NFPA70E and other safety protocols and leave the panels closed • Extend the life of your equipment with more frequent IR scans • Easy to install • Durable enough to withstand extreme outdoor conditions yet practical for indoor applications as well. Specifications (Check the Fluke web for detailed specifications) Included Accessories Installation CD, self-adhesive drilling template, security access key, warranty statement. Ordering Information FLK-075-CLKT FLK-100-CLKT IP-200-UK 75mm C-Range IR Window, Kwik Twist 100mm C-Range IR Window, Kwik Twist Window Installation Kit 220/240V Optic Data Crystal Insert Diameter Viewing Aperture Diameter Viewing Aperture Area Thickness CLIRVU Coating Shortwave IR Capable Midwave IR Capable Longwave IR Capable Ultraviolet (UV) Capable Visual Capable Fusion Capable General Maximum Temperature Gaskets Body Optic Gaskets IP rating NEMA rating Vibration rating Humidity rating Pull out strength FLK-075-CLKT FLK-100-CLKT 75 mm 68 mm 3632 mm2 2 mm 100 mm 89 mm 6322 mm2 4 mm O O O O O O O O O O O O O O 250º C 659 º C 1400º C Low Smoke & Fume (LSF) compliant silicone IP65 Typo 3/12 (UL & CSA Third Party Certified) IEC60068-2-6 IEC60068-2-3 Up to 630 kg Warranty: Lifetime replacement against manufacturing defects 59 Ti9/Ti10 Electrical Thermal Imagers The rugged and affordable tools for electricians and technicians Get the full picture instantly with the Fluke Ti9/Ti10 thermal imagers. Built for tough work environments, these fully radiometric imagers are ideal for detecting problems in a wide range of equipment including switchgear, motor control centers and lighting systems. Fluke Ti10 • Enhanced problem detection and analysis capabilities with patent pending IR-Fusion® Technology (Ti10) • Intuitive, three-button menu is easy to use ... simply navigate with the push of a thumb • Store more than 3.000 screen images (.bmp format) or 1.200 fully radiometric images (.IS2 format) on included 2 GB SD memory card • The Fluke Ti9 can be upgraded to a full Fluke Ti10 with IR-Fusion at a later time. • Delivers the clear images to find problems fast with its 160x120 sensor • Even the smallest details become visible with the large, widescreen full color LCD display • Optimized for field use in harsh work environments - Engineered and tested to withstand a 2 meter drop - Withstands dust and water – tested to an IP54 rating - Innovative protective lens cover protects the lens when not in use Specifications (Check the Fluke web for detailed specifications) Fluke Ti9 New Fluke Ti9 Thermal imaging performance Detector type Field of view (FOV) Spatial resolution (IFOV) Min focus distance Thermal sensitivity (NETD) Minimum span (Auto/Manual) Focus Visual imaging performance Min focus distance On camera operating modes Visible light camera Temperature measurement Temperature range Accuracy Measurement modes Image presentation Digital display LCD backlight Palettes Image and data storage Storage medium File formats supported Controls and adjustments Set-up controls Language selection Image controls Power Battery type Battery operating time Fluke Ti10 160 x 120 Focal Plane Array, uncooled microbolometer 23 º horizontal x 17 º vertical 2.5 mrad 15 cm ≤0.2 °C at 30 °C (200 mK) 10 ˚C / 5 ˚C Manual 46 cm Picture-in-Picture and full screen IR 1.3 MegaPixel -20 ˚C to 250 ˚C ± 5 °C or 5% Center point 9.1 cm (3.6") landscape color VGA (640x480) LCD Selectable bright or auto Ironbow, blue-red, high contrast, grey 2GB SD Card (3000 .bmp IR images/1200 .IS2 images) JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF Date/time,˚C/˚F, language Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur Smooth auto scaling and manual scaling Internal rechargeable battery NiMh (included) 3 to 4 hours continuous operation Complete package Included Accessories SmartView® software 2 GB SD card SD card reader Rugged hard carrying case Soft carrying case Hand strap Rechargeable battery AC charger/power supply User manual Training DVD Battery life: 3 to 4 hours continuous operation Water and dust resistant: IP54 Size (HxWxD): 267 x 127 x 152 mm Weight: 1.2 kg Two Years Warranty Recommended Accessories Ordering Information 60 Fluke Ti9 Fluke Ti10 Electrical Thermal Imager Thermal Imager Ti-Visor Sun Visor (for complete Ti Series) Ti-Car Charger Car charger Ti-TRIPOD Tripod Mounting Base Accessories (for complete Ti Series) Ti25/Ti32 Industrial Thermal Imagers New The ultimate tools for troubleshooting and maintenance NETD of 0.1ºC for the Ti25 and 0.05ºC for the Ti32 to view the smallest details. For added versatility and special applications, the Ti32 includes two fieldswappable, rechargeable batteries. Use the optional telephoto and wide-angle lens to bring distant and wide views into sharp focus. The Fluke Ti32 combines a powerful 320x240 sensor into the award winning, rugged design of the Fluke Ti25, delivering the first industrial grade, high performance thermal imager. The result is strikingly crisp, detailed images that, blended with patented IR-Fusion®, are sure to make a lasting impression. The Fluke Ti32 and Ti25 have all the features of the Fluke Ti10, but with an Specifications Fluke Ti32 (Check the Fluke web for detailed specifications) Fluke Ti25 Thermal imaging performance Detector type Fluke Ti25 Field of view (FOV) Spatial resolution (IFOV) Min focus distance Thermal sensitivity (NETD) Minimum span (Auto/Manual) Focus Optional lenses Telephoto infrared lens type Wide-angle infrared lens type Visual imaging performance Min focus distance On camera operating modes Color Alarm Visible light camera Temperature measurement Temperature range Accuracy Measurement modes Image presentation Digital display LCD backlight Palettes O O 46 cm Picture-in-Picture and full screen IR plus Blending High temperature alarm 1.3 MegaPixel 2.0 MegaPixel -20 ˚C to 350 ˚C -20 ˚C to 600 ˚C ± 2 °C or 2% Center point and hot and cold markers 9.1 cm (3.6") landscape color VGA (640x480) LCD Selectable bright or auto Ironbow, Blue-Red, High Contrast, Amber, Hot Ironbow, Blue-Red, High Contrast, Amber, Metal, Grey Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Palettes Ultra Contrast Voice Annotation Voice annotation Image and data storage Storage medium File formats supported Controls and adjustments O O Complete package Battery operating time O 2GB SD Card (3000 .bmp IR images/1200 .IS2 images) JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF Date/time, Cº/ºF, language On screen emissivity correction On-screen reflected background temperature compensation On-screen transmission correction Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur Smooth auto scaling and manual scaling Set-up controls Language selection Image controls Power Battery type Fluke Ti32 160 x 120 Focal Plane Array, uncooled 320 x 240 Focal Plane Array, uncooled microbolometer microbolometer 23 º horizontal x 17 º vertical 2.5 mrad 1.25 mrad 15 cm ≤0.1 °C at 30 °C (100 mK) ≤0.05 °C at 30 °C (50 mK) 2.5 ˚C / 5 ˚C Manual Internal rechargeable battery NiMh (included) 3 to 4 hours continuous operation Two replaceable rechargeable battery packs (Lithium ion) 4+ hours per battery pack Included Accessories SmartView® software 2 GB SD card SD card reader Rugged hard carrying case Soft carrying case Hand strap Rechargeable battery AC charger/power supply User manual Training DVD Water and dust resistant: IP54 Size (HxWxD): Ti25: 267 x 127 x 152 mm Ti32: 277 x 122 x 170 mm Weight: Ti25: 1.2 kg Ti32: 1.05 kg Two Years Warranty Recommended Accessories Ordering Information Fluke Ti25 Fluke Ti32 Industrial Thermal Imager Industrial Thermal Imager FLK-LENS/TELE1 Telephoto Infrared Lens (Ti32) FLK/LENS/WIDE Wide-angle Infrared Lens (Ti32) Ti-Car Charger Car charger FLK-TI-SPB3 Extra battery (Ti32) FLK-TI-SBC3 Charging base (Ti32) 61 TiRx/TiR Thermal Imagers for Building Inspection Optimized for energy audits, restoration and remediation Fluke TiR The affordable rugged Fluke TiRx and TiR - Innovative protective lens cover Thermal Imagers are workhorse tools protects the lens when not in use for the demands of building envelope, • Enhanced problem detection and restoration and remediation, inspection analysis capabilities with patent pending and roofing applications. Whether IR-Fusion® Technology (TiR) • Intuitive, three-button menu is easy to to perform energy audits, locate the use ... simply navigate with the push of a origins of construction problem or to thumb find roof leaks, the TiRx and TiR offer • Store more than 3.000 screen images an economical solution for complete (.bmp format) or 1.200 fully radiometric detection, analysis and documentation. images (.IS2 format) on included 2 GB SD memory card • Delivers the clear images to find problems fast with its 160x120 sensor • The Fluke TiRx can be upgraded to a full Fluke TiR with IR-Fusion at a later time. • Even the smallest details become visible with the large, widescreen full color LCD display • Optimized for field use in harsh work environments - Engineered and tested to withstand a 2 meter drop - Withstands dust and water – tested to an IP54 rating Specifications (Check the Fluke web for detailed specifications) New Fluke TiRx Complete package Fluke TiRx Thermal imaging performance Detector type Field of view (FOV) Spatial resolution (IFOV) Min focus distance Thermal sensitivity (NETD) Minimum span (Auto/Manual) Focus Visual imaging performance Min focus distance On camera operating modes Visible light camera Temperature measurement Temperature range Accuracy Measurement modes Image presentation Digital display LCD backlight Palettes Image and data storage Storage medium File formats supported Controls and adjustments Set-up controls Language selection Image controls Power Battery type Battery operating time Fluke TiR 160 x 120 Focal Plane Array, uncooled microbolometer 23 º horizontal x 17 º vertical 2.5 mrad 15 cm ≤0.1 °C at 30 °C (100 mK) 2.5 ˚C / 5 ˚C Manual 46 cm Picture-in-Picture and full screen IR 1.3 MegaPixel -20 ˚C to 100 ˚C ± 5 °C or 5% Center point 9.1 cm (3.6”) landscape color VGA (640x480) LCD Selectable bright or auto Ironbow, blue-red, high contrast, grey 2GB SD Card (3000 .bmp IR images/1200 .IS2 images) JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF Date/time, ˚C/˚F, language Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur Smooth auto scaling and manual scaling Internal rechargeable battery NiMh (included) 3 to 4 hours continuous operation Included Accessories SmartView® software 2 GB SD card SD card reader Rugged hard carrying case Soft carrying case Hand strap Rechargeable battery AC charger/power supply User manual Training DVD Water and dust resistant: IP54 Size (HxWxD): 267 x 127 x 152 mm Weight: 1.2 kg Two Years Warranty Recommended Accessories Ordering Information 62 Fluke TiRx Fluke TiR Inspector Thermal Imager Thermal Imager Ti-Visor Sun Visor (for complete Ti Series) Ti-Car Charger Car charger Ti-TRIPOD Tripod Mounting Base Accessories (for complete Ti Series) TiR1/TiR32 Thermal Imagers for Building Diagnostics New The top professional’s choice The TiR1 and TiR32 Thermal Imagers are the top professional’s choice for building diagnostics. With its 320 x 240 sensor, the TiR32 delivers the clear, crisp images needed to find problems fast. The Fluke TiR1 and TiR32 have all the features of the Fluke TiR, but with an NETD of 0.07ºC for the TiR1 and 0.05ºC for the TiR32 to identify even small temperature differences that could indicate problems. For added versatility and special applications, the TiR32 includes dewpoint measurements and two field-swappable, rechargeable batteries. Use the optional telephoto and wide-angle lens to bring distant and wide views into sharp focus. Fluke TiR32 Specifications (Check the Fluke web for detailed specifications) Fluke TiR1 Thermal imaging performance Detector type Fluke TiR1 Field of view (FOV) Spatial resolution (IFOV) Min focus distance Thermal sensitivity (NETD) Minimum span (Auto/Manual) Focus Optional lenses Telephoto infrared lens type Wide-angle infrared lens type Visual imaging performance Min focus distance On camera operating modes Color Alarm Visible light camera Temperature measurement Temperature range Accuracy Measurement modes Image presentation Digital display LCD backlight Palettes O O 46 cm Picture-in-Picture and full screen IR plus Blending Dewpoint alarm 1.3 MegaPixel 2.0 MegaPixel -20 ˚C to 100 ˚C -20 ˚C to 150 ˚C ± 2 °C or 2% Center point and hot and cold markers 9.1 cm (3.6") landscape color VGA (640x480) LCD Selectable bright or auto Ironbow, Blue-Red, High Contrast, Amber, Hot Ironbow, Blue-Red, High Contrast, Amber, Metal, Grey Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Palettes Ultra Contrast Voice Annotation Voice annotation Image and data storage Storage medium File formats supported Controls and adjustments O O Complete package Battery operating time O 2GB SD Card (3000 .bmp IR images/1200 .IS2 IR-Fusion images) JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF Date/time, Cº/ºF, language On screen emissivity correction On-screen reflected background temperature compensation On-screen transmission correction Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur Smooth auto scaling and manual scaling Set-up controls Language selection Image controls Power Battery type Fluke TiR32 160 x 120 Focal Plane Array, uncooled 320 x 240 Focal Plane Array, uncooled microbolometer microbolometer 23 º horizontal x 17 º vertical 2.5 mrad 1.25 mrad 15 cm ≤0.07 °C at 30 °C (70 mK) ≤0.05 °C at 30 °C (50 mK) 2.5 ˚C / 3 ˚C Manual Internal rechargeable battery NiMh (included) 3 to 4 hours continuous operation Two replaceable rechargeable battery packs (Lithium ion) 4+ hours per battery pack Included Accessories SmartView® software 2 GB SD card SD card reader Rugged hard carrying case Soft carrying case Hand strap Rechargeable battery AC charger/power supply User manual Training DVD Water and dust resistant: IP54 Size (HxWxD): TiR1: 267 x 127 x 152 mm TiR32: 277 x 122 x 170 mm Weight: TiR1: 1.2 kg TiR32: 1.05 kg Two Years Warranty Recommended Accessories Ordering Information Fluke TiR1 Thermal Imager for Building Diagnostics Fluke TiR32 Thermal Imager for Building Diagnostics FLK-LENS/TELE1 Telephoto Infrared Lens (Ti32) FLK/LENS/WIDE Wide-angle Infrared Lens (Ti32) Ti-Car Charger Car charger FLK-TI-SPB3 Extra battery (Ti32) FLK-TI-SBC3 Charging base (Ti32) 63 Laser Distance Meters The Fluke Laser Distance Meters bring you the most advanced measuring technology. Unlike ultrasonic distance meters with laser pointers, these meters use a precision narrow laser beam that can avoid the common errors caused by extraneous objects near measurement targets. 64 421D, 416D, 411D Laser Distance Meters New Professional-grade laser distance measuring tools that are fast, easy to use, and fit in your pocket. The Fluke laser distance meters bring you the most advanced measuring technology. These meters are fast, accurate, durable, and easy to use — just point and shoot. Their straightforward design and easy, one-button operation mean you spend less time measuring. Unlike ultrasonic distance meters with laser pointers, the Fluke 421D, 416D and 411D use a precision narrow laser beam that can avoid the common errors caused by extraneous objects near measurement targets. These compact and handy Fluke distance meters are designed for indoor, and limited outdoor applications. Addition, subtraction, area, and volume calculations could not be simpler. The extra bright laser is clearly visible so you can see your targeting point even if an object is hard-to-reach or distant. The Fluke 421D, 416D and 411D have a large LCD screen and buttons positioned for onehanded measurements. Features Fluke 421D 411D 416D 421D Reduction of estimation errors, saving both time and money O O O Instant measurement with one-button operation O O O Easy targeting with bright laser O O O Quick calculation of area (square footage) and volume O O O Easy addition and subtraction of measurements O O O Improved battery life from automatic shut-off feature O O O Pythagoras calculation for determining distance indirectly from two other measurements O O O Pouch O O O O O 30 m 60 m 100 m - Ability to view more with large, 3-line display with backlight Ability to measure up to Storage capacity of measurements for quick recall of distance Fluke 411D Fluke 416D 10 20 MIN/MAX function O O Enhanced Pythagoras calculation for determining distance indirectly from three other measurements O O Audible feedback of on and off modes O O Strong environment protection with IP54 (water spray & dust proof) sealing O O Audible feedback for taking room angle and incremental measurements O ± 45° Tilt sensor for taking indirect measurements in hard to reach areas O Tripod mode allows you to mount to a tripod for measuring long distances O Built in light sensor for activating the backlight saving battery life O Corner angle feature, allows you to determine the angle of a corner O Specifications (Check the Fluke web for detailed specifications) Range (for extended distances, use a target plate) Accuracy 411D/62 Kit Combo kit includes: - Fluke 62 Mini IR Thermometer - Fluke 411D Laser Distance Meter - Soft pouch for each model Included Accessories Two AAA batteries, Users manual on CD, Quick start guide, Nylon carrying case, Wrist wrap (421D) Measurement units Fluke 411D Fluke 416D 30 m 60 m 100 m ± 3 mm ± 1.5 mm ± 1.5 mm 00.000 m Measurement storage Backlight Automatic power off Operating temperature: 0°C to 40°C Storage temperature: -25°C to 70°C Operating altitude: up to 3500 m Battery Life: 411D: up to 3000 readings 416D, 421D: up to 5000 readings After 180 seconds Fluke 421D 00.000 m 00.000 m 10 locations 20 locations O O After 180 seconds After 360 seconds Size (HxWxD): 411D: 123 mm x 50 mm x 26 mm 416D: 135 mm x 46 mm x 31 mm 421D: 127 mm x 52 mm x 25 mm Weight: 411D: 0.150 kg 416D: 0.110 kg 421D: 0.125 kg Warranty: 2 years Ordering Information Fluke 411D Fluke 416D Fluke 421D Laser Distance Meter Laser Distance Meter Laser Distance Meter 65 Indoor Air Quality Tools In response to the growing importance of air quality in buildings, workplaces and homes, Fluke offers you a range of tools that monitor temperature, humidity, air velocity, particulate, and carbon monoxide levels. These tools help you to quickly and easily troubleshoot and maintain indoor air quality, as well as to verify the efficient operation of heating, ventilation and air conditioning systems. 66 975 AirMeter Combined inspection tool for complete air quality inspections The Fluke 975 AirMeter combines five air monitoring tools into one, rugged and easy-to-use handheld tool. Use the Fluke 975 to verify the efficient operation of heating, ventilation and air conditioning systems, and test for dangerous carbon monoxide leaks in all types of buildings. • Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display • One-touch air flow and velocity measurements with available probe • Min/Max/Average on all measured and calculated readings • Audible and visual threshold alarms • Multi-language user interface • Extensive discrete or continuous data logging capacity, down-loadable to PC via USB interface Specifications (Check the Fluke web for detailed specifications) Feature Measured specifications Temperature Range Display resolution Accuracy -20 °C to 60 °C 0.1 °C 10 % to 90 % RH noncondensing 50 fpm to 3000 fpm 0.25 m/sec to 15 m/sec 1 fpm 0.005m/sec CO2 0 to 5000 ppm 1 ppm CO 0 to 500 ppm 1 ppm ± 0.9 °C from 40 °C to 60 °C ± 0.5 °C from 5 °C to 40 °C ± 1.1 °C from -20 °C to 5 °C ± 2 % RH (10 % RH to 90 % RH) 4 % or 4 fpm* 3 % or 0.015 m/sec* whichever is greater *Accuracy specification only valid for velocity readings above 50 fpm. Warm up time 1 min (5 minutes for full specification) 2.75 % + 75 ppm ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH Calculated specifications Dew point temperature -44 °C to 57 °C 0.1 °C Wet bulb temperature -16 °C to 57 °C 0.1 °C 0 to 3,965 M3/m 0 to 140,000 cfm) 0.001 M3/min (1 cfm) 0 to 100 % 0 to 100 % 0.1 % 0.1 % Relative humidity Air velocity 1% Fluke 975 Volume flow rate (in a duct) % outside air (based on temperature) % outside air (based on CO2) Operating temperature (CO and CO2 sensors): -20 °C to 50 °C Operating temperature (all other functions): -20 °C to 60 °C Storage temperature: -20 °C to 60 °C Humidity: 10% to 90% Altitude: Up to 2000 m Included Accessories ± 1 °C when temp: -20 °C to 60 °C RH: 40 % to 90 % ± 2 °C when temp: -20 °C to 60 °C RH: 20 % to 40 % ± 4 °C when RH: 10 % to 20 % ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C ± 2.1 °C when RH: 10 % to 20 % N/A: The volume flow calculation will be a simple average of the data points times the duct area N/A N/A Shock and vibration: MIL-PRF-28800F, Class 2 Battery: Rechargeable Li-Ion (primary), threeAA (backup) Weight: 0.544 kg Size (HxWxD): 28.7 cm x 11.43 cm x 5.08 cm Data logging: 25,000 records (continuous), 99 records (discrete) Multilanguage interface: English, French, Spanish, Portuguese and German Two-year warranty A4 alkaline batteries (3), Users Manual, Calibration Cap, FlukeView Forms Software, Power Adapter, International Power Plugs, Air Velocity Probe (Fluke 975V only) Ordering Information Fluke 975 Fluke 975V 975CK 975R 975VP Recommended Accessories AirMeter AirMeter with Velocity Airmeter Calibration Kit Regulator Air Velocity Probe 975VP AirMeter Velocity Probe 67 922 Airflow Meter Measures pressure, air flow and velocity for maintaining balanced and comfortable ventilation The Fluke 922 makes airflow measurements easy by combining pressure, air flow, and velocity into a single, rugged meter. Compatible with most Pitot tubes, the Fluke 922 allows technicians to conveniently enter their duct shape and dimensions for maximum measurement accuracy. • Provides differential and static pressure, air velocity and flow readings • Convenient colored hoses help you properly diagnose pressure readings • Bright, backlit display for clear viewing in all environments • Min/Max/Average/Hold functions for easy data analysis • Auto power off saves battery life Use the Fluke 922 to: Ensure proper air flow balance and maintain a comfortable environment; measure pressure drops across filters and coils; match ventilation to occupant loads; monitor indoor vs. outdoor pressure relationships and manage the building envelope; and perform duct traversals for accurate airflow readings. Specifications (Check the Fluke web for detailed specifications) Feature Range Resolution Accuracy Operating Specifications Air Pressure Air Velocity Fluke 922 Air Flow (Volume) Temperature ± 4000 Pascals ± 16 in H2O ± 400 mm H2O ± 40 mbar ± 0.6 PSI 250 to 16,000 fpm 1 to 80 m/s 0 to 99,999 cfm 0 to 99,999 m3/hr 0 to 99,999 l/s 0 °C to 50 °C 1 Pascal 0.001 in H2O 0.1 mm H2O 0.01 mbar 0.0001 PSI 1 fpm 0.001 m/s 1 cfm 1 m3/hr 1 l/s 0.1°C ± 1% +1 Pascal ± 1% + 0.01 in H2O ± 1% + 0.1 mm H2O ± 1% +0.01 mbar ± 1% + 0.0001 PSI ± 2.5 % of reading at 10 m/s (2000 p/min) Accuracy is a function of velocity and duct size ± 1 % + 2 °C General Specifications General specifications Operating Temperature Storage Temperature Operating Relative Humidity IP Rating Operating Altitude Storage Altitude EMI, RFI, EMC Vibration Max Pressure at Each Port Included Accessories Fluke 922: Two Rubber Hoses, Wrist Strap, Four AA Batteries 1.5 V Alkaline, Users Manual and Soft Carrying Case Fluke 922 Kit Includes: Fluke 922 Airflow Meter, 30.48 cm Pitot tube, ToolPak, Two Rubber Hoses, Wrist Strap, Four AA Batteries 1.5 V Alkaline, Users Manual and Hard Carrying Case Ordering Information Fluke 922 Fluke 922/Kit 0 ºC to +50 ºC -40 ºC to +60 ºC Non condensing (<10 ºC) 90% RH (10 ºC to 30 ºC) 75% RH (30 ºC to 40 ºC) 45% RH (40 ºC to 50 ºC) Without Condensation IP40 2000 m 12000 m Meets requirements for EN61326-1 MIL-PREF-28800F, Class 3 10 PSI Data Storage: 99 readings Size (HxWxD): 175 x 775 x 419 mm Weight: 0.64 kg Battery: Four AA batteries Battery Life: 375 hours without backlight, 80 hours with backlight Two Year Warranty Fluke 922/Kit Recommended Accessories Air Flow Meter Airflow Meter with 30.48 cm Pitot Tube PT12 Pitot Tube, 30.48 cm 68 TPAK Toolpak See page 120 971 Temperature Humidity Meter Carbon Monoxide Meters Fluke 971 Temperature Humidity Meter Quickly take accurate humidity and temperature readings in the air. Temperature and humidity are two important factors in maintaining optimal comfort levels and good indoor air quality. The Fluke 971 is invaluable for facility maintenance and utility technicians, HVAC-service contractors, and specialists who assess indoor air quality (IAQ). Lightweight, rugged, and easy to hold, the Fluke 971 is the perfect tool for monitoring problem areas. • Simultaneously measures humidity and temperature • Measures dew point and wet bulb • 99 record storage capacity • Min/Max/Avg Data Hold • Ergonomic design with built-in belt clip and protective holster • Backlit, dual readings display • Twist-open protective cap • Low battery indicator Specifications Fluke 971 Other useful tools Fluke 561 Fluke 416D Combined Contact and Non-contact Thermometer See page 54. Laser Distance Meter See page 65. Temperature range Temperature accuracy 0 ºC to 45 ºC -20 ºC to 0 ºC and 45 ºC to 60 ºC Resolution Response time (temperature) Temperature sensor type Relative humidity range Relative humidity accuracy 10% to 90% R.H. @ 23 ºC <10%, >90% R.H. @ 23 ºC Humidity sensor Data storage Response time (humidity) -20 ºC to 60 ºC ± 0.5 0C ± 1.0 ºC 0.1 ºC 500 ms NTC 5% to 95% R.H. ± 2.5 % R.H. ± 5.0 % R.H. Electronic capacitance polymer film sensor 99 points For 90% of total range - 60 sec with 1 m/s air movement Operating temperature: Temperature: -20 °C to 60 °C Humidity: 0 °C to 60 °C Storage temperature: : -20 °C to 55 °C Battery life: 4 AAA alkaline, 200 hours Safety: Complies with EN61326-1 Weight: 0.188 kg Size (HxWxD): 194 mm x 60 mm x 34 mm One Year Warranty Carbon Monoxide Meters CO-220 Carbon Monoxide Meter Included Accessories Fluke CO-220: C50 soft carrying case and battery The CO-220 Carbon Monoxide Meter makes it easy to take quick and accurate measurements of CO levels. A large, backlit LCD display shows CO levels from 0 to 1000 PPM. The MAX Hold function stores and displays the maximum CO level. 1 year warranty. Fluke CO-220 Ordering Information Fluke 971 Fluke CO-220 CO-205 Temperature Humidity Meter Carbon Monoxide Meter Aspirator Kit CO-205 Aspirator Kit Allows flue gas samples up to 371°C to be drawn with the CO-220 for carbon monoxide measurement. 1 year warranty. Fluke CO-205 69 983 Particle Counter / RLD2 Leak Detector Flashlight Easy to use tool for troubleshooting and maintaining indoor air quality The Fluke 983 Particle Counter simultaneously measures and displays six channels of particle size distribution, temperature and humidity. This compact, lightweight, self-contained tool allows for one-handed operation. As the Fluke 983 doesn’t require level holding, it can make accurate measurements in any position. The 8 hour rechargeable battery together with a large 5000 sample record allows for complete air quality surveys in one go. The Fluke 983 is the ideal tool for determining size distribution of airborne particles or tracking down a particle source. • Simultaneously measure and display 6 channels of particle sizes, temperature and humidity • Measure particle size down to 0.3 μm • Selectable sample time, count data, programmable delay • Store 5000 records of date, time, counts, relative humidity, temperature, sample volumes, alarms and location label • Upload stored data to a PC with included software • Compact, self-contained package allows for one-handed operation • Intuitive, easy-to-use user interface • Always ready to run, with no fluids to refill • Backlit LCD for use in any lighting condition Specifications Fluke 983 6 size channels Flow rate Count modes Counting efficiency Zero count Coincidence loss Relative humidity Temperature Data storage Alarms Delay time Sample inlet Interface Calibration 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 μm 0.1 cfm (2.83 L/min) controlled by internal pump Concentration, totalize, audio 50 % @ 0.3 μm; 100 % for particles > 0.45 μm (per JIS B9921:1997) 1 count/5 minute (per JIS B9921:1997) 5 % at 56,000 particles per m3 ± 7 %, 20 % to 90 %, non-condensing ± 3 °C, 10 °C to 40 °C 5000 sample records (rotating buffer) of date, time, counts, relative humidity, temperature, sample volumes, alarms, label Counts, low battery, sensor fail 0 to 24 hours Isokinetic probe RS-232 and RS-485 via RJ-45 PSL particles in air (NIST traceable) Operating temperature: 10 °C to 40 °C, 20 % to 90 % relative humidity, non-condensing Storage temperature: -10 °C to 50 °C, up to 90 % relative humidity, non-condensing Power: AC adapter, 90 to 250 V AC, 50 to 60 Hz Battery life/recharge time: 8 hours/2 hours RLD2 Leak Detector Flashlight Included Accessories Fluke 983: Certificate of Calibration (NIST) Isokinetic probe Zero count filter Windows-compatible software download utility DB9 to RS-232 adapter and cable High purity tubing 1/8 in. hose barb adapter Power supply Operation manual Hard molded carrying case Fluke RLD2: Key chain carabiner and batteries. Ordering Information Fluke 983 Particle Counter Fluke RLD2 Leak Detector Flashlight 70 Rechargeable battery: NiMH, 4.8V at 4.5 Ah; replaceable Size (HxWxD): 209 mm x 114 mm x 57 mm Weight: 1 kg Warranty: 1 year New RLD2 Leak Detector Flashlight. Leak detection made easy. The compact RLD2 uncovers refrigerant leaks instantly. Use the UV light to find the leakage area, then, use the laser pointer to pinpoint the exact leak location. • Six UV LEDs detect leak detection dyes • Laser pointer clearly locates center of the UV field for accuracy • Three LED flashlight with 100,000 hour LED life • Operating temperature 0ºC to 50ºC • Four operating modes: flashlight, UV light, laser light, UV/laser light combination • One year warranty ScopeMeter® Test Tools With the original ScopeMeter, we transformed the oscilloscope category beyond recognition, and we still lead the way today. From rugged solutions for industrial applications to full-colour models that pack topend bench oscilloscope specifications into hand-held, battery powered instruments. In short, ScopeMeter provides you with unmatched speed, performance and analysis power while working on site. 71 ScopeMeter® Test Tools Oscilloscopes for field applications Features 225C 215C LDC Display Persistence O O O O O O O O Waveform reference Automatic pass fail testing Cursors and zoom Connect and View triggering Video triggering with line selector Selectable pulse width triggering Capture and replay of last 100 screens O O O O O O O O Dual input TrendPlot The ScopeMeter 190C Series of high performance oscilloscopes have bandwidth of 60, 100 and 200 MHz and sample rates up to 2.5 GS/s. These instruments offer a highresolution color display that has a fast update rate, waveform pass/fail testing and a digital persistence mode – making the analysis of complex and dynamic signals much easier. For industrial electronic or electro mechanical applications, the 120 Series Industrial ScopeMeter, with a 20 or 40 MHz bandwidth and Connect-andView™ triggering for an instant, stable display will get the job done. 199C 196C 192C 125 124 Color 123 B/W O O O O O O O O O O O O O O O O O O O O O O O O Cursors O O O O O O With cursors and Zoom O O O Memory for screens and set-ups 10 screens and setup 20 20 10 Recorder memories, each can store 100 scope screens, a ScopeRecord or a TrendPlot 2 recorder memories O O O O/O O/O 1000V Independently floating isolated outputs Meter measurements: VAC RMS, VAC+DC, Ohms, Continuity, Diode, Amps, Temp. (ºC, ºF) Waveform mathematics: A+B, A-B, AxB, A versus B (X-Y mode) Frequency Spectrum Analysis using FFT Power measurements and VPWM Capacitance and frequency measurements Bus Health Test function Rugged, dust and drip proof case (IP51) PC and printer interface via optically isolated RS232/USB cable FlukeView® for Windows® Software (SW90W) OStandard equipped 1) Optional O O O O O O O O O O O O O O O O O -/O O O O O -/O O O O O -/O O O -/O O O -/O O O O O O/O O O O O 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 2) 2) Harmonics mode Specifications (Check the Fluke web for detailed specifications) 225C 215C 199C 196C 192C Bandwidth 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz Max. real time sample rate 2.5 GS/s 1 GS/s 2.5 GS/s 1 GS/s 500 MS/s 125 124 123 Oscilloscope specifications Input sensitivity 2 mV/div. ...1000 V/div Timebase range 5 ns/div. ...2 min/div. Inputs and digitizers 40 MHz 20 MHz 25 MS/s 5 mV/div. ...500 V/div. 10 ns/div. ...2 min/ div. 10 ns/div. ...1min/div. 2 plus external trigger/DMM input Independently floating isolated outputs Max. record length... ... in Scope mode: ... in ScopeRecorde mode: Glitch capture 20 ns/div. ...1 min/div. 2 Up to 1000 V between inputs, references and ground 3000 points per input 27.500 points per input or more (5 ms/div. to 2 min/div.) Up to 3 ns using Pulse Width triggering; 50 ns peak detect at 5 μs/div. to 1 min/div. Scope measurements 512 min/max points per input 40 ns cursors + 26 automatic 7 cursor measurements, 30 automatic measurements Automatic Vrms and watts measurement on cursor limited part of waveform True RMS multimeter 5000 counts, single input 26 automatic ...plus power measurements and Vpwm 5000 counts, dual input General specifications Line power Adapter/battery charger included (BC190) Battery (installed) Size Weight Safety certified (EN61010-1) Warranty 72 >3,5 hr Ni-MH (BP190) Adapter/battery charger included (PM8907) 7 hr Ni-MH (BP120 MH) 256 x 169 x 64 mm 232 x 115 x 50 mm 2 kg 1.2 kg 1000 V CAT II / 600 V CAT III 600 V CAT III 3 years on main products and 1 year on accessories Check the Fluke web site for Technical Specifications and Application Notes for the Fluke ScopeMeters ScopeMeter® 120 Series Three-in-one simplicity The compact ScopeMeter 120 Series is the rugged solution for industrial troubleshooting and installation applications. It’s a truly integrated test tool, with oscilloscope, multimeter and “paperless” recorder in one affordable, easy-to-use instrument. Find answers to problems in machinery, instrumentation, control and power systems quickly and easily. Fluke 125 Fluke 124 • Dual-input 40 MHz or 20 MHz digital oscilloscope • Two 5,000 counts true-RMS digital multimeters • A dual-input TrendPlot™ recorder • Bus Health Test for industrial bus systems (Fluke 125) • Connect-and-View™ trigger simplicity for hands-off operation • Power Measurements and Harmonics measurement (Fluke 125) • Shielded test leads for oscilloscope, resistance and continuity measurements • Up to 7 hours battery operation • 600 V CAT III safety certified • Optically isolated interface for PC and Printer connection (optional) • Rugged, compact case Connect-and-View™ triggering for an instant, stable display Fluke 123 True RMS stable, reliable and repeatable display of virtually any signal - including motordrive and control signals - without touching a button. Signal changes are instantly recognized and settings adjusted for - once again - a stable display. Use TrendPlot™ to help find intermittents fast The toughest faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it – your Fluke ScopeMeter will. In this “paperless recorder” mode, you can plot the minimum and maximum peak values and average over time – up to 22 days (Fluke 190 Series) or 16 days (Fluke 120 Series). Bus Health mode (Fluke 125) Bus Health mode gives a clear “Good/ Bad” indication for the electrical signals on industrial buses and networks, such as CAN-bus, Profi-bus, RS-232 and many more. The Fluke 125 validates the quality of the electrical signals as soon as any electrical signals are passed along the network. Scope users know how difficult triggering can be. Wrong settings show unstable and sometimes wrong results. Fluke’s unique Connect-and-View recognizes signal patterns, and automatically sets up correct triggering. It provides a Included Accessories PM 8907 line adapter/charger, STL120 shielded test leads set (1 red, 1 grey), AC120 Alligator Clips, BB120 shielded BNC adapter, BP120MH NiMH battery pack, VPS40 wide bandwidth Voltage Probe (Fluke 124/125), TL75 hard point test lead, i400s current clamp (Fluke 125), Getting Started booklet, user’s manual (cd-rom) Ordering Information Fluke 123 Industrial ScopeMeter® (20MHz) Fluke 123/S Industrial ScopeMeter® (20MHz) + SCC120 kit Fluke 124 Industrial ScopeMeter® (40MHz) Fluke 124/S Industrial ScopeMeter® (40MHz) + SCC120 kit Fluke 125 Industrial ScopeMeter (40 MHz) Fluke 125/S Industrial ScopeMeter (40 MHz) + SCC120 kit SCC120 FlukeView® Software + OC4USB Cable + Carrying Case OC4USB USB Interface Cable PM9080 RS-232 Interface Cable DP120 Differential Voltage Probe ITP120 Isolated Trigger Probe SW90W FlukeView Software BHT190 Set of 3 break-out adapters (Fluke 125) Connect-and-View captures even the most complex motor drive signals. Bus Health mode allows for an analysis of the signal quality on an industrial network. See page 72 for specifications. Recommended Accessories SCC120 C125 See page 118 DP120 See page 76 OC4USB See page 76 SCC128 See page 113 73 ScopeMeter® 190C Series (incl. 225C and 215C) Speed, performance and analysis power For more demanding applications, the ScopeMeter 190C Series high performance oscilloscopes offer specifications usually found on top-end bench instruments. With up to 200 MHz bandwidth, 2.5 GS/s real-time sampling and a deep memory of 27500 points per input they’re ideal for engineers who need the full capabilities of a high performance oscilloscope in a handheld, battery powered instrument. Fluke 199C Fluke 196C Fluke 192C • Dual input – 60, 100 or 200 MHz models • Up to 2.5 GS/s real time sampling per input • Bus Health Test capability for industrial buses, including Profi, Foundation, ModBus and many more (225C and 215C) • High resolution color display • High waveform resolution of max. 3000 datapoints per channel • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope • Fast display update rate (> 100/sec) for seeing dynamic behavior instantaneously • Connect&View™ automatic triggering, a full range of manual triggering modes plus external triggering. • Automatic capture and replay of 100 screens • 27500 points per input record length using ScopeRecord mode • Up to 1000 V independently floating isolated inputs • Waveform reference for visual comparisons and automatic pass/fail testing of waveforms • Vpwm function for motor drive and frequency inverter applications. • Waveform mathematics: Add, Subtract and Multiply • Frequency Spectrum Analysis using FFT • X-vs-Y mode (Lissajous display) for study of signal relationships • Cursors, zoom and real-time clock • 30 automatic waveform measurements • Over 3.5 hours rechargeable Ni-MH battery pack • Includes a 5000 count true-RMS multimeter and a TrendPlot™ paperless recorder ScopeMeter for medical imaging and video test applications Fluke 225C Fluke 215C True RMS On all inputs 74 For tests on such systems, an optional configuration is available. Please check the Fluke website for further details. Bus Health Test (225C and 215C) Bus Health Test analyses the electrical signals on an industrial bus or network and gives a clear “Good”, “Weak” or “Bad” validation mark for each of the relevant parameters, presented next to the actual measurement value. The Fluke 225C and 215C can make the signal quality validation as soon as electrical signals are passed along the network, without looking at the data content. They find errors like improper cable connections, bad contacts, incorrect grounding and missing or superfluous terminators. Automatic capture and replay of 100 screens Scope users know how frustrating it is to see a one time anomaly flash by, never to be seen again. Not with the ScopeMeter 190C Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can “freeze” the last 100 screens and scroll through pictureby-picture or replay as a ‘live’ animation. Cursors can be used for further analysis. You can even use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC. ScopeMeter® 190C Series (incl. 225C and 215C) See dynamic signal behavior instantaneously Frequency Spectrum Analysis 190C The Digital Persistence mode helps to find anomalies and to analyze complex dynamic signals by showing the waveforms amplitude distribution over time using multiple intensity levels and user selectable decay time - it’s as if you’re looking at the display of an analog, real time oscilloscope! A fast display update rate reveals signal changes instantaneously, useful for instance when making adjustments to a system under test. All 190C Color ScopeMeters include Frequency Spectrum Analysis on Fast Fourier Transformation (FFT) analysis as a standard feature. This makes it possible to identify the individual frequency components contained in a signal. The spectrum analysis function is also handy to reveal the effects of vibration, signal interference or crosstalk. An automatic window function assures optimal windowing, although you may manually select your preferred time window. Pulse width fluctuations are clearly visible using Digital Persistence Frequency Spectrum shows an overview of frequencies contained in a signal. FlukeView® Software for documenting, archiving and analysis FlukeView® for Windows® helps you get more out of your ScopeMeter by: • Documenting - transfer waveforms, screens and measurement data from the ScopeMeter to a PC. Print or import the data into your report • Archiving - create a library of waveforms with your comments for easy reference and comparison • Analysis - use cursors, perform spectrum analysis or export data to other analysis programs FlukeView Screen Included Accessories BC190 Battery Charger BHT190 Set of 3 break-out adapters (225C/215C) BP190 NiMH Battery Pack VPS210-G + VPS210-R Voltage Probe TL75 Hard Point Test Lead Set user’s manual (CD-Rom), Getting Started Booklet Ordering Information Fluke 192C Fluke 196C Fluke 199C Fluke 215C Fluke 225C Fluke 192C/S Fluke 196C/S Fluke 199C/S Fluke 215C/S Fluke 225C/S SCC190 SCC191 C190 SW90W Color ScopeMeter (60 MHz, 500 MS/s) Color ScopeMeter (100 MHz, 1 GS/s) Color ScopeMeter (200 MHz, 2.5 GS/s) Color ScopeMeter with Bus Health Test (100 MHz, 1 GS/s) Color ScopeMeter with Bus Health Test (200 MHz, 2.5 GS/s) 192C + SCC191 kit option 196C + SCC191 kit option 199C + SCC191 kit option 215C + SCC191 kit option 225C + SCC191 kit option SW90W FlukeView Software, OC4USB cable, C190 briefcase style carrying case SW901W FlukeView Software, OC4USB cable, industrial style carrying case Briefcase style carrying case FlukeView Software Thanks to the deep memory, very small parts of the waveform can be studied in full detail using “zoom”. See page 72 for specifications. Recommended Accessories ScopeMeter SCC191 Scopemeter SCC190 C195 See page 118 OC4USB See page 76 SCC198 See page 113 75 ScopeMeter® Accessories ScopeMeter probes VPS40 Description Number and color Attenuation Bandwidth DC-MHz Length (m) EN 61010-2 CAT II EN 61010-2 CAT III ScopeMeter 190 Series ScopeMeter 120 Series VPS210-R series VPS40 Voltage Probe Set One Black 10:1 40 1.2 1000 V 600 V VPS210-G series VPS210-R VPS210-G Voltage Probe Set 1 Red VPS212-R VP212-G Voltage Probe Set 1 Grey 1 Red 10:1 200 MHz 1.2 m 1000 V 600 V O 1 Grey VPS220-R VPS220-G Voltage Probe Set 1 Red 10:1 200 MHz 2.5 m 1000 V 600 V O O O O PM8918/301 DP120 1 Grey 100:1 200 MHz 1.2 m 1000 V 600 V O O O O VPS101 Voltage Probe Set 1 Black 1:1 30 MHz 1.2 m 300 V O DP120 Differential Probe Set Red & Grey 200:1, 20:1 20 1.5 1000 V 600 V O O1) PM8918/301 Low Pass Filter Probe One Blue 10:1 4 kHz 2.5 600 V O O1) 1) Using BB 120 PM9091/9092 Description Length EN 61010-2 CAT III ScopeMeter 190 Series ScopeMeter 120 Series PM9081 PM9091 50 Ω BNC cable set (1Red, 1Grey, 1Black) 1.5 m 300 V O O1) PM9082 PM9092 50 Ω BNC cable set (1Red, 1Grey, 1Black) 0.5 m 300 V O O1) PM9093 PM9081 Dual Banana plug male to female BNC PM9082 Dual Banana jack female to male BNC PM9093 Male BNC to dual female BNC 600 V O O 600 V O O1) 600 V O O1) 1) Using BB 120 RS200 RS200 AS200-R AS200-G PM9080 OC4USB PM9090 PM9094 PAC91 76 AS200-R Probe Accessory Replacement Set for VPS Series Probes Probe Accessory Set, Red for VPS Series Probes Probe Accessory Set, Grey for VPS Series Probes Optical Interface Adapter Cable for serial port Optical Interface Adapter Cable for USB Port Probe Pin Grabber Flexible Clip for VPS Series Probes Mini Testhook Set for PM8918 Probes Printer Adapter Cable OC4USB PM9080 Battery Packs BP120MH BP190 PM9090 NiMH Battery Pack for 120 Series + 43B NiMH Battery Pack for 190 + 430 Series All accessories have a one year warranty Power Quality Tools and Power Analyzers We offer an extensive range of power quality test tools for troubleshooting, predictive maintenance and long-term recording in industrial and utility applications. For the development and test of electrical equipment, our high-precision power analyzers enable easy and reliable use in the field or as a bench unit in test laboratories. 77 78 Detailed RMS trending shows how connected loads behave. RMS voltage RMS Current Energy studies Measure V, I, kW, Cos/DPF, kWhr Measure MIN/MAX and AVG values 10 day logging Energy aggregation Utility meter pulse input Energy Loss (Eff. kW, Reactive kVAR, Unbalance kVAR, Distortion kVAR, Neutral kVAR) Basic harmonics study THD measurement (V & I) Harmonics 1 to 25 for V & I Tabular values Neutral current measurement Crest factor Advanced harmonics study Full harmonic spectrum Power harmonics Harmonics 1 to 50 and dc k-factor %Fundamental and %RMS Basic Industrial PQ Troubleshooting Oscilloscope function Voltage dips and swells Phasor diagram Trend recording Inrush current Advanced industrial PQ troubleshooting Comprehensive logging capability Transient capture Flicker EN50160 analysis Complex System interaction event capture (manual threshold setting) Random/variable system event capture (Adaptive threshold setting) Utility PQ benchmarking Phase sequence components Interharmonics Mains signaling IEC61000-4-30 Class A Software PowerLog PQLog Power Analyze PQ Analyze FlukeView Forms Go to www.fluke.co.uk/pq or www.fluke.eu/pq to see the video Power Quality in Industrial Applications Covers the basics of power quality and looks at the tools and inspection techniques used to troubleshoot common problems. VIDEO O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O 430 O O To make use of the power data you collect, you need software that can help analyze your findings and share them with equipment providers and plant management. O O O O O O O O O O O O O O O O O O O O O O O O O O 43B O O O O O O Single phase 345 O O O O O O O O O O O O VR1710 O Before you install sensitive loads, make sure you understand the existing quality of power delivered by your utility. Comparing benchmarks over time can help pinpoint potential areas of concern. Complex installations often require a deeper dive into measurement data. Multiple loads may be interacting randomly to cause a single problem. When troubleshooting in the field, graphical data enables you to trace the source of the problem at hand. If distorting loads are causing problems in your installation, you need comprehensive data to intentify the source and create a solution. Discover the source of distortion in your installation, so that you can filter those loads or move them to separate circuits. Get detailed power and energy consumption profiles during energy audits and pinpoint savings opportunities. Application use Basic measurements Power quality tools help pinpoint problems fast O O O O O O O O O O O O O O 1735 O O O O O O O O O O(no DC) O O O O O O O O O O O Three phase 1740 O O(not 1743) O O O O O O O O O O O O O O O O O O O O O O O O O O O O O 1750 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O 1760 O O Power Quality Selection Guide VR1710 Single-Phase Voltage Quality Recorder Easy-to-use solution for detecting and recording voltage quality problems Fluke VR1710 The Fluke VR1710 is a single-phase, plugin voltage quality recorder that provides fast and easy recording of voltage trends, dropouts, harmonics and general power quality including dips and surges to help maintenance and facilities management personnel easily pinpoint the root cause of voltage problems. Voltage quality parameters including RMS average, transients, flicker, and harmonics up to the 32nd are recorded using a userselected average period from 1 second to 20 minutes. • Clear graphical summary of data and quick overview of key power quality parameters • Get the complete picture with Min, Max, Average RMS values (1/4 cycle) with time stamps • See the detailed with actual transient display (> 100 μs) with time stamp • Comprehensive analysis of Individual harmonic and THD values with trends Applications • Voltage recording – Monitors and records supply voltage; measures RMS average, minimum and maximum values, and checks whether the socket outlet is providing voltage within tolerance. • Distortion measurement – Measure frequency and harmonics; check whether the distorting loads (UPS systems, drives, etc.) are affecting your other equipment. • Flicker measurement – Quantify the affects of switching loads on lighting systems. • Voltage transients – Capture those intermittent, momentary events that may be affecting your equipment; the full waveform is captured with date, timestamp, and duration. Fluke VR1710 and included accessories PowerLog Setup – Simple set up of internal clock, logging periods, and intervals with default values for quick results. PowerLog View – Data presentation showing RMS voltage and harmonic trends, actual transients, summary information and statistics in accordance with EN50160. Actual transient display (> 100 μs) with time stamp– Quickly identify issues with included graphical software. Statistical analysis of voltage event – reduces analysis time by tracking event quantities and magnitudes. Specifications (Check the Fluke web for detailed specifications) Includes PowerLog software Included Accessories Plug-in Fluke VR1710, USB cable, PowerLog software CD, universal power cord adapters. Operating voltage Min/Max/Avg RMS value Number of events Dips/Interruptions Time resolution Voltage resolution) Over-voltages Frequency Harmonics measurement Flicker measurement Number of recording channels Recording time Transients Frequency range Safety category rating 70 V to 300 V Resolution 0.125 V 175,000 Yes 5 ms 0.125 V Yes Yes EN 61000-4-7 (up to 32nd) EN 61000-4-15 1 Phase to Neutral 2 Phase/Neutral to Ground 1 day to 339 days depending on average time from 1 second to 20 minutes Yes (> 100μs) 50 Hz ± 1 Hz and 60 Hz ± 1 Hz CAT II 300 V Ordering Information Fluke VR1710 Voltage Quality Recorder Display: LED Size (HxWxD): 23 x 19.75 x 22.2 cm Weight: 0.8 kg Two years warranty 79 345 Power Quality Clamp Meter The ideal troubleshooting tool for modern electrical loads The Fluke 345 measures a wide range of electrical parameters for troubleshooting power disturbances in single- and three-phase electrical loads. With a bright color display to see waveforms and trends, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 is ideal for measurements on switching loads such as variable speed drives, electronic lighting and UPS systems. • High safety rating: 600V CAT IV / 1000V CAT III rated for use at the service entrance • ac/dc current measurements: Clampon measurement of ac peak and dc current up to 2000 A without breaking the circuit • Harmonic analysis: Analyze, display and log harmonics up to the 30th harmonic (40th harmonic for 15 Hz to 22 Hz) • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems Specifications (Check the Fluke web for detailed specifications) Fluke 345 Current measurement DC, DC rms, AC rms All measurements DC and 15 Hz to 1 kHz. Maximum overload 10,000 A or RMS x frequency < 400,000. Amps rms is a true rms measurement (AC + DC). 0 – 2000 A dc or 1400 AC rms All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A Measuring range Harmonics Voltage measurement DC, DC rms, AC rms All measurements DC and 15 Hz to 1 kHz. Maximum overload 1,000 V rms. Volts rms is a true-rms measurement (AC + DC). 0 – 825 V DC or AC rms All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Vacrms > 1V Measuring range Harmonics Watts measurement (single- and three-phase) Measuring range View waveforms for equipment checking and setup VA measurement (single- and three-phase) Measuring range DC, DC rms, AC rms 0 – 1650 kW DC or 1200 kW ac DC, DC rms, AC rms 0 -1650 kVA DC or 1200 kVA ac VAR measurement (single- and three-phase) Measuring range 0 – 1250 kVAR Power factor (single- and three-phase) Measuring range 0.3 cap…1.0… 0.3 ind (72.5° cap…0°… 72.5° ind) Displacement power factor Measuring range 0.3 cap … 1.0 … 0.3 ind (72.5° cap ... 0° ... 72.5° ind) Kilowatt Hour (kWHr) Measuring range 40,000 kWHr Scope function Time base Current management: Ranges Voltage measurement: Ranges 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div 10 A/20 A/40 A/100 A; 200 A/400 A/1000 A/2000 A 4 V/10 V/20 V/40 V/100 V; 200 V/400 V/1000 V All measurements dc and 15 Hz to 1 kHz 40, 400 and 2000 A Up to 50 screen shots and over 150,000 individual measurement values Inrush current function Ranges Log parameters over time to track down intermittent faults Memory Power supply: 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 Battery Battery life (typical): >10 hours (backlight on full); >12 hours (backlight reduced) Safety: IEC 61010-1 600 V CAT IV, 1000V CAT III (maximum input phase-phase 825V rms) double or reinforced insulation, pollution degree 2 Protection: IP40; EN60529 Operating temperature: 0 °C to 50 °C Display: Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight Digital output: USB interface to a PC Size (HxWxD): 300 mm x 98 mm x 52 mm Jaw opening: 60 mm Jaw capacity: 58 mm diameter Weight (including batteries): 0.82 kg Two Year Warranty Included Accessories Soft carrying case, Power Log software, Test probes, Test leads, Alligator clips, International ac adapter / battery eliminator, Printed English User manual, Multi-language manual on CD Recommended Accessories Ordering Information Fluke 345 Power Quality Clamp Meter TLK291 See page 111 80 TP220 See page 111 AC220 See page 112 TP1 See page 111 C550 See page 118 43B Single-phase Power Quality Analyzer The perfect tool for tracking down single-phase power-related problems The Fluke 43B is the choice for diagnosing and troubleshooting power quality and general equipment failures. Ease to use thanks to menu selection of the power modes, it combines the capabilities of a power quality analyzer, a 20 MHz oscilloscope, a multimeter and a data recorder in a single instrument. • Voltage, current, and power harmonics • Up to 51st harmonic • Total harmonic distortion (THD) • Phase angle of individual harmonics • Continuously measure volts and amps on a cycle-by-cycle basis for up to 16 days • Use cursors to read time and date of sags and swells • Watts, power factor, COS ij, VA and VAR • Voltage and current waveforms • Connect-and-View™ scope for quick waveform display • View voltage and current channels simultaneously Fluke 43B Specifications (Check the Fluke web for detailed specifications) Menu items Volts/Amps/Hz On all inputs Power Harmonics True RMS Sags & Swells Transient Capture Inrush Current Ohms/Continuity/ Capacitance Temperature (with accessory) Scope Included Accessories TL224 test lead set, AC220 alligator clip set, TP4 test probe set, BP120MH rechargeable battery pack, BB120 shielded BNC adapter, PM8907 line adapter/charger, i400s AC current clamp, AB200 alligator clip set, TP1 test probe set, C120 hand carrying case, OC4USB interface cable, SW43W FlukeView software, VPS 40 voltage probe, Fluke 61 IR thermometer, user and application manual. Screen saves Recording Measurements Volts Amps Mains frequency CF Crest Factor Watts, VAR, VA PF, DPF, COS ij Volts Amps Watts K-factor Voltage and Current 40 ns pulse width Up to 40 transients 1 sec. to 5 min selectable Ohms Capacitance ºC ºF DC, AC, AC+DC, peak, peak-peak, Hz, duty cycle, phase, pulse width, crest factor All functions V/A/Hz, Power, Harmonics, Ω/Cap, Temperature, Scope Accuracy ±(1%+10) ±(1%+10) ±(0.5%+2) ±(5%+1) ±(4%+4) ±0.04 ±0.03 ±(3%+2) to ±(15%+5) ±(3%+8) to ±(15%+5) ±(5%+2) to ±(30%+5) ±10% ±(2%+10) ± 5% of full scale ± 5% of full scale ± (0.6%+5) ± (2%+10) ± (0.5%+5) 25 MS/sec 20 MHz 15 kHz Select any two parameters display mode in each Battery life: Rechargeable Ni-MH pack (charger included), 6 hrs typical (continuous) Shock & Vibration: Mil 28800E, Type 3, Class III, Style B. Operating temperature: 0°C to 50°C; Case: IP51 (dust, drip, waterproof) Size (HxWxD): 232 mm x 115 mm x 50 mm; Weight: 1.1 kg Three Years Warranty Ordening information Fluke 43B Ranges 5.000 V - 1250 V 50.00A - 50.00 kA 40.0 - 70.0 Hz 1,0 à 10,0 250 W - 1.56 GW 0.25 W-0.9 0.90-1.00 1 st to 51 st harmonic 1 st to 51 st 1 st to 51 st 1.0 to 30.0 4 min-16 days selectable Select 20/50/100/200% above or below line voltage 1 A to 1000 A 500.0 Ω to 30.00 MΩ 50.00 nF to 500.0 μF -100.0ºC to 400.0ºC -200.0ºF to 800.0ºF Sampling rate: Bandwidth: Voltage BW (Channel 1) Current BW (Channel 2) 20 screens 4 min - 16 days selectable Recommended Accessories Power Quality Analyzer (single-phase) i2000flex See page 114 i1000s See page 114 80TK See page 116 PAC91 See page 76 81 430 Series Three-phase Power Quality Analyzers Pinpoint power quality problems faster, safer and in greater detail The Fluke 435 and 434 three-phase power quality analyzers help you locate, predict, prevent and troubleshoot problems in power distribution systems. These easy-touse handheld tools have many innovative features to give you the details to pinpoint problems faster and safer. Fluke 435 Fluke 434 True RMS On all inputs • Complete three-phase troubleshooting tool: measures virtually every power system parameter: voltage, current, frequency, power, power consumption (energy), unbalance and flicker, harmonics and inter-harmonics. Captures events like dips and swells, transients, interruptions and rapid voltage changes. • The Fluke 435 features 0.1 percent voltage accuracy making it fully compliant with the IEC 61000-4-30 Class A standard • Logger: record the detail you need. Detailed, user-configurable long-time recording gives you the MIN, MAX and AVG readings of up to 100 parameters on all 4 phases with selectable averaging time down to 0.5 seconds. Enough memory is available to record 400 parameters with 1 minute resolution for up to a month. • Four channels: simultaneously measures voltage and current on all three phases and neutral. • AutoScaling: easier trend analysis with automatic scaling of the vertical axis you will always use the full display to view the waveforms. • Automatic transient display: captures up to 40 dips, swells, interruptions or transients automatically. • Meets the stringent 600 V CAT IV, 1000 V CAT III safety standard required for measurements at the service entrance. • Rugged, handheld instrument operates for more than 7 hours on included rechargeable NiMH battery pack. Menudriven interface simplifies operation. • Extensive data analysis possibilities. Cursors and zoom can be used ‘live’ while taking the measurements, or ‘offline’ on stored measurement data. The stored measurements can also be transferred to a PC with FlukeView software (included with Fluke 435 and 434). • The Fluke 435 comes with Power Log software to analyse recorded data and to create reports. • Complete package includes everything to get started: 4 current clamps, 4 flex clamps with Fluke 435, 5 voltage test leads and clips, line adapter/battery charger and hard case. • Complies with IEC 61000-4-30 measurement standards. AutoTrend - Quickly see the trend Unique AutoTrend gives you fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or interval times, or having to manually start the process. You can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral. And you can analyze the trends using the cursors and zoom function – even while background recording continues. SystemMonitor - Check performance against EN50160 with ease With a single push of a button, the unique System-Monitor gives you an overview of power system performance, and checks the compliance of incoming power to EN50160 limits or to your own custom specifications. The overview is shown on a single screen, with color-coded bars clearly indicating which parameters fall outside the limits. The System-Monitor overview screen gives instant insight into whether the voltage, harmonics, flicker, frequency and the number of dips and swells fall outside the set limits. A detailed list is given of all events falling outside the set limits. 82 AutoTrend automatically records all displayed parameters in the background. 430 Series Three-phase Power Quality Analyzers Logging function allows you to customize measurement selections and provides instantaneous analysis of userselectable parameters. Measure and record power (W), VA and VARs. The 434 and 435 add the ability to record energy consumption. Track harmonics up to the 50th, and measure and record THD in accordance with IEC61000-4-7 requirements Specifications (Check the Fluke web for detailed specifications) Fluke 435 with flex clamps Inputs Number of inputs Maximum input voltage Maximum sampling speed 4 voltage and current (3 phases + neutral) 1000 Vrms (6kV Peak) 200 kS/s on each channel simultaneously Volt/Amps/Hertz Vrms (AC+DC) Vpk Crest factor, voltage Arms (AC+DC) Apeak Crest factor, A Hz 50Hz nominal Vrms (AC+DC) 2 Arms (AC+DC) 2 Harmonic (interharmonic) (n) Vrms Arms Watts 1…1000 V ± 0.1% of nominal voltage 1…1400 V 5% of Vnom 1.0 ... > 2.8 ± 5% 0…20,000 A ± 0.5% ± 5 counts 0 - 5500 A 5% 1 … 10 ± 5% 42.50 ... 57.50 Hz ± 0.01Hz 0.0% ….100% of Vnom ± 0.2% of nominal voltage 0 … 20,000 A1 ± 1% ± 5 counts DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7 0.0 … 1000 V ± 0.05% of nominal voltage 0.0 … 4000 mV x clamp scaling ± 5% ± 5 counts depends clamp scaling and ± 5% ± n x 2% or reading, voltage ± 10 counts 0.0 … 1000 V ± 0.2% of nominal voltage 0.0 … 100.0 % ± 2.5% V and A (± 5% Watt) 0 … 3500 Hz ± 1 Hz -360º ... +360º ± n x 1.5º 1.0 … 20.00 MVA1 ± 1% ± counts 00.00 …200.0 GVAh1 ± 1.5% ± 10 counts 0…1 ± 0.03 0.00 … 20.00 ±5% 0.0 … 5.0% ± 0.5% 0.0 … 20% ± 1% ± 6000 V ± 2.5% of Vrms 5 μs (200 kS/s sampling) 1 0.000 … 20.00 kA ± 1% of meas ± 5 counts 7.5 s … 30 min ± 20 ms (Fnom = 50 Hz) 5 readings/sec continous sampling per channel 1800 min, max and avg points for each reading Up to 450 days Up to 12x horizontal zoom 50, shared memory divided between logging, screens and data sets IEC61000-4-30 class A; EN50160; IEC 61000-4-15; IEC 61000-4-7 Dips and swells Harmonics Included Accessories Fluke 435/434: Hard carrying case C430 (434)/ Water-tight hard case with rollers C435 (435) 4 current clamps, i400s, CAT IV 600 V (Fluke 434) 4 current clamps, i430-Flex-4pk, CAT IV 600 V (Fluke 435) 5 Test leads, 4 black, 1 green Battery Charger Eliminator, BC430 FlukeView Software, SW43W Power Log Software (435) Optical Cable for USB, OC4USB Color localization set, WC100 Getting Started printed User Manual (CD-ROM) Basic versions: Excl. current clamps Power and Energy Flicker Unbalance Transient capture Inrush mode AutoTrend recording Memory Standards DC voltage THD Hz Phase angle Watt, VA, VAR kWh, kVAh, kVARh Power Factor/ Cos ij / DPF Pst (1min), Pst, Plt, PF5 Volts Current Volts Minimum detect duration Arms (AC+DC) Inrush duration (selectable) Sampling Memory Recording time Zoom Screens & data Measurement methods used Ordering information Fluke 435/Basic Fluke 435 Fluke 434/Basic Fluke 434 Fluke 434/LOG OC4USB PM9080 GPS430 Power Quality Analyzer (three phase) Power Quality Analyzer (three phase) Power Quality Analyzer (three phase) Power Quality Analyzer (three phase) Logger Upgrade Kit: Adds the Logger Function of the 435 to the 434 Serial Interface Adapter/ Cable (USB) Serial Interface Adapter/ Cable (RS232) GPS sync module for 430 Series 1 2 depending clamp scaling Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle Battery life: > 7 hours with rechargeable NiMH (installed); Battery charging time: 4 hours typical Safety: EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV Case: Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof) Shock: 30 g; Vibration: 3g according to MIL-PRF-28800F Class 2 Operating temperature: 0°C to +50°C Size (HxWxD): 256 mm x 169 mm x 64 mm; Weight: 1.1 kg Three Years Warranty Recommended Accessories GPS430 i430-flex-4pk See page 88 i5sPQ3 See page 88 i1000s See page 144 OC4USB See page 76 See page 88 for power quality current clamps 83 1735 Power Logger Performs electrical load studies, energy consumption testing, and general power quality logging Fluke 1735 The Fluke 1735 Power Logger is the ideal tool for electricians and maintenance technicians for conducting energy studies and basic power quality logging. The 1735 is easy to set up with its color display and four included flexible current probes. The 1735 logs most electrical power parameters, harmonics and captures voltage events. View graphs and generate reports with the included Fluke Power Log software. View recorded data in simple graphs and tables with Fluke Power Log software. • Record power and associated parameters for up to 45 days • Monitor maximum power demand over user-defined averaging periods • Prove the benefit of efficiency improvements with energy consumption tests • Measure harmonic distortion caused by electronic loads • Improve reliability by capturing voltage dips and swells from load switching • Confirm instrument setup easily with color display of waveforms and trends Conduct load studies for up to 45 days and view saved data on-screen or on a computer. Access voltage and current harmonics up to the 50th. Quantify energy consumption quickly on-screen or log to memory for extended periods. Capture voltage events using user-defined thresholds. Customize the report generator to easily generate professional looking reports. Specifications (Check the Fluke web for detailed specifications) Volts rms Amps rms Frequency Harmonics and THD Power measurement (P - Active, S - Apparent, Q - Reactive, D - Distorting) Energy Measurement (kWh, KVAh, kVARh) PF (Power factor) Events General Memory Sample rate Line frequency Included Accessories FS17XX 4-phase flexible current clamp set, VL1735/1745 voltage lead set, Power Log software, color localization set, PC interface cable, international ac adapter, BC1735 battery charger, soft carrying case, printed English manual and multi-language manual on CD. Ordering Information Fluke 1735 Power Logger V-rms wye measurement ranges: 57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/ 400 V/417 V/480 V AC V-rms delta measurement ranges: 100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/ 690 V/720 V/830 V AC Flexi set measurement range: 15 A/150 A/3000 A rms (at sine) Current clamp measurement range: 1 A/10 A Measurement range: 46 Hz to 54 Hz and 56 Hz to 64 Hz To 50th harmonic (< 50 % of nom) Measuring range: see V-rms and A-rms measurement ranges Measuring range: see V-rms and A-rms measurement rangeso 0.000 to 1.000 Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms. 4 MB Flash memory, 3.5 MB for measuring data 10.24 kHz 50 Hz or 60 Hz, user-selectable, with automatic synchronization Display: VGA Graphic Color transmissive displays 320 x 240 pixels with additional background lighting and adjustable contrast, text and graphics in color Interface: RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS-232 interface (9-pole extension cable) Housing: IP65; EN60529 (refers only to the main housing without the battery compartment) Power supply: NiMH battery-pack, with AC adapter (15 V to 20 V/0.8 A) Battery Life: Typical > 16 hours without backlight and > 6 hours with backlight high Operating temperature: 0°C to +40°C Size (HxWxD): 240 mm x 180 mm x 110 mm Weight: 1.7 kg, including battery Two Year Warranty Recommended Accessories See page 88 for power quality current clamps 84 1740 Series Three-Phase Power Quality Loggers Memobox Assess power quality and conduct long-term studies with ease Compact, rugged and reliable, the Fluke 1740 Series three-phase power quality loggers are everyday instruments for technicians who troubleshoot and analyze power distribution systems. Capable of simultaneously logging up to 500 parameters for up to 85 days and capturing events, the Fluke 1740 Series helps uncover intermittent and hard-tofind power quality issues. There are three models to choose from to meet your basic or advanced power logging needs. Fluke 1743 Fluke 1744 Fluke 1745 Fluke 1743: IP65 waterproof monitor for logging the most common power parameters including V, A, W, VA, VAR, PF, energy, flicker, voltage events and THD. • Plug and play: Set up in minutes with automatic current probe detection and powering • Installs inside the cabinet: Compact, fully-insulated housing and accessories fit easily in tight spaces next to live power • Monitors power for the long-term: Data can be downloaded during recording without interruption • Measure voltage with premium accuracy: IEC61000-4-30 Class-A compliant voltage accuracy (0.1%) • Quickly validate quality of power: Assess power quality according to EN50160 power quality standard with statistical overview Fluke 1744: Includes the same features as the Fluke 1743. In addition to common power parameters, the Fluke 1744 also measures voltage and current harmonics, interharmonics, mains signaling, unbalance, and frequency. Fluke 1745: Advanced IP50 power quality logger with the same measurement capability as the 1744, plus real-time LCD, five hour UPS. Specifications The included PQ Log software helps you to quickly identify the root cause of a disturbance. Included Accessories Fluke 1743/1744/1745: FS17XX flexible current clamp set , VL1735/1745 voltage lead set (1745 only), Power Log software, RS232 interface cable and RS232-USB adapter, 4 black dolphin clips, WC17XX color localization set, carrying bag, test certificate with measurement values, printed English manual and multi-language manual on CD. Basic models: Excl. current clamps FS17XX Ordering Information Fluke 1743 Basic Fluke 1743 Fluke 1744 Basic Fluke 1744 Fluke 1745 Power Quality Logger Memobox Power Quality Logger Memobox Power Quality Logger Memobox Power Quality Logger Memobox Power Quality Logger Memobox (Check the Fluke web for detailed specifications) Measurement of common power parameters: V, A, W, VA, VAR, PF, energy, flicker, voltage events (dips, swells, interruptions), and THD Measurement of voltage and current harmonics to the 50th, unbalance, frequency and mains signaling Dust/water resistance Display Memory UPS ride-through EN 50160 1745 O 1744 O O O IP 50 LED + LCD 8 MB > 5 hrs O LED 8 MB 3s O Power supply: 88 V … 660 V AC Safety: IEC/EN 61010-1 600 V CAT III, 300 V CAT IV, pollution degree 2, double insulation Housing: Fully insulated housing and accessories Operating temperature: 0 °C to 35°C Interface: RS 232, 9600 ... 115 000 Baud, automatic Baud rate selection, 3-wire communication 1743 O IP 65 waterproof LED 8 MB 3s O Fluke 1745: 282 mm x 216 mm x 74 mm; Fluke 1743/44: 170 mm x 125 mm x 55 mm Weight: Fluke 1745 – approx. 3 kg; Fluke 1743/44: approx. 2 kg Two Year Warranty Size: See page 88 for power quality current clamps 85 1750 Three-Phase Power Recorder New Never miss capturing a disturbance With its exclusive threshold-free measurement system, the Fluke 1750 Power Recorder captures every measurement, every event, on every cycle, all the time. Outstanding accuracy and resolution provide complete visibility into your installation or distribution system. On all inputs • Power quality that meets the standard: All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc. • Quick and reliable configuration: PDA wireless “front panel interface” provides the ability to verify setup without a laptop along with a window into what the instrument is recording, even in awkward test locations. • Threshold-free setup: Apply thresholds after data is collected with Fluke Power Analyzer Software so there is no need to worry about missed information due to incorrect set-up. • Captures everything: Cross-channel and current triggering capture every measurement, on every channel, every time. • Intuitive PC software: Easily analyze data and generate reports. Automated EN50160 reporting and compliance. • Plug and play: Set up in minutes with selfidentifying current probes and single-lead voltage connections. • No need to reconnect wires: Swap channels internally with the wireless PDA or PC when connections are not correct. • Measure every parameter: Voltage and current on three phases, neutral, and ground. • 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events. • Quickly retrieve data: With included SD memory card or via the 100BaseT highspeed Ethernetv connection View measurements real time with wireless PDA interface Specifications (Check the Fluke web for detailed specifications) Power quality measurement standards Conformance Clock/calendar Real-time clock accuracy Internal memory capacity for data Maximum recording period Measurement time control Maximum number of events Power requirements Operating time during interruptions (internal UPS operation) Included Accessories PDA and charger power plug adapters, 4 - 400 A current probes (3140R), 5 test leads and clips, SD memory card., Fluke Power View and Fluke Power Analyze software, power cord with international plug set, Ethernet cable, color localization set, soft carrying case, Printed Getting Started manual, CD with software and users manual PDF Basic model: excl. 4 current probes (3140R) Ordering Information Fluke 1750/B Fluke 1750 86 Three-Phase Basic Power Recorder Three-Phase Power Recorder IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160 Leap years, 24-hour clock Not more than ± 1 s/day At least 1 GB At least 31 days Automatic Limited only by the size of the internal memory 100 to 240 V rms ± 10 %, 47-63 Hz, 40 W 5 minutes per interruption, 60 minutes total operating time without recharging Safety: EN 61010-1 2nd Edition; 2000 Weight: 6.3 kg Size (H x W x D): 215 x 310 x 35 mm One Year Warranty Recommended Accessories Model 3110-PR 3210-PR 3310-PR 3312-PR 3005-PR 3014-PR 3140R FLUKE-1750/SEAT-L FLUKE-1750/SITE-L FLUKE-1750/CASE CS1750 HP IPAQ 2490 FLUKE-1750/MC Description Flexible Current Transformer (2 A - 100 A) Flexible Current Transformer (20 A – 1000 A) Flexible Current Transformer (100 A - 5000 A) Flexible Current Transformer (100 A – 5000 A) Clamp-on Current Transformer (0.01 A – 5 A) Clamp-on Current Transformer (0.1 A – 40 A) Clamp-on Current Transformer (2 A – 400 A) Fluke Power Analyze – Additional SEAT LICENSE Fluke Power Analyze – Additional SITE LICENSE Hard Case Soft Case Additional Wireless Interface PDA Additional 512 MB SD Memory Card 1760 Three-Phase Power Quality Recorder Topas Class-A compliance for the most demanding power quality tests Fluke 1760 The Fluke 1760 Three-Phase Power Quality Recorder is fully compliant to IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium and low-voltage networks, the Fluke 1760 provides the flexibility to customize thresholds, algorithms, and measurement selections. It has 8 input channels (4 currents/4 voltages or 8 voltages), and captures the most comprehensive details on user selectable parameters. • GPS time synchronization: Correlate data with events or datasets from other instruments with precision • Uninterrupted power supply (40 minutes): Never miss important events - even record the beginning and end of interruptions and outages • 10 MHz, 6000 Vpk waveform capture: Get a detailed picture of even the shortest event • 2 GB data memory: Enables detailed, simultaneous recording of numerous power parameters for long periods of time • Includes Comprehensive software: Provides trend diagrams for root cause analysis, statistical summaries, report writing and real-time data monitoring in the online mode Features (Check the Fluke web for detailed specifications) The included PQ Analyze software provides a detailed overview of several power quality parameters on one dashboard according to the EN50160 power quality standard. Included Accessories 4 x TPS Flex 24 flexible current probe, 4 x TPS VoltProbe 6000V, 2 GB internal flash memory, ST1760 standard Ethernet cable, RS232 interface cable and RS232-USB adapter, CS1760 crossover Ethernet cable, 1 mains cable, PC software on CD-ROM, WC17xx color localization set, GPS-time sync (1760TR only) CS 1750/1760 carrying bag, hardware and software manual Basic models: Excl. current clamps TPS flex 24 Ordering Information Fluke 1760 Basic Power Quality Recorder Topas Fluke 1760TR Basic Power Quality Recorder Topas Fluke 1760 Power Quality Recorder Topas Fluke 1760TR Power Quality Recorder Topas Power quality statistics according to EN50160 Voltage event list (dips, swells and interruptions) Continuous recording of: Voltage Current Power P, Q, S Power factor kWh Flicker Unbalance Frequency Voltage and current harmonics to the 50th/ Interharmonics THD Mains signaling Triggered recordings Online mode (Oscilloscope, transients and events) Fast transient analysis up to 10 MHz 4 voltage probes 4 dual-range flexible current probes (1000 A / 200 A ac) GPS time sync receiver Memory 1760 Basic 1760TR Basic 1760 1760TR O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O 2 GB Flash memory Power supply: 83 V to 264 V, 45 to 65 Hz Battery pack: NIMH, 7.2 V, 2.7 Ah (up to 40 minutes back-up power supply) Safety: 600V CAT IV/1000V CAT III (Rated for use at the service entrance) Housing: Fully insulated robust plastic housing Operating temperature: 0 °C to 35°C Interfaces: Ethernet (100 MB/s), RS-232, external modem via RS-232 Size (HxWxD): 325 mm x 300 mm x 65 mm Weight: Approxiamtely 4.9 kg Two Year Warranty Recommended Accessories (Check the Fluke web for complete accessory list) Model • TPS VOLTPROBE 10 V • TPS VOLTPROBE 100 V • TPS VOLTPROBE 400 V • TPS VOLTPROBE 600 V • TPS VOLTPROBE 1 KV • TPS FLEX 18 • TPS FLEX 24 • TPS FLEX 36 • TPS CLAMP 10 A / 1 A • TPS CLAMP 50 A / 5A • TPS CLAMP 200 A / 20 A • TPS SHUNT 20 MA • TPS SHUNT 5 A Description 10 V Voltage Probes (Range: 0.1 V to 17 V) 100 V Voltage Probes (Range: 1 V to 170 V) 400 V Voltage Probes (Range: 4 V to 680 V) 600 V Voltage Probes (Range: 10 V to 1000 V) 1000 V Voltage Probes (Range: 10 V to 1700 V) Flexible Current Probe (Range: 1 A to 100 A / 5 A to 500 A) Flexible Current Probe (Range: 2 A to 200 A / 10 A to 1000 A) Flexible Current Probe (Range: 30 A to 3000 A / 60 A to 6000 A) Clip-on Current Transformer (Range: 0.01 A to 1 A / 0.1 A to 10 A) Clip-on Current Transformer (Range: 0.05 A to 5 A / 0.5 A to 50 A) Clip-on Current Transformer (Range: 0.2 A to 20 A / 2 A to 200 A) 20 mA ac/dc Shunt (Range: 0 to 55 mA) 5 A ac/dc Shunt (Range: 0 to 10 A) 87 88 Basic accuracy: % reading plus floorspec. n/a = not applicable 1 BNC to banana adapters included n/a i3000 flex-4PK (4x i3000s flex24) n/a One connector n/a One connector i400s n/a One connector 2 CAT III 600 V n/a n/a One connector 2 CAT III 600 V i430-flex-4PK One connector 2 CAT III 600 V n/a One connector 2 CAT III 1000 V CAT IV 600V One connector 2 CAT III 600 V 3.75 mV/A Connection 2 CAT III 600 V 3.75 mV/A 3300 A 450 mA 2%+2% position influence 40Hz …5kHz 450mA … 15A 600mA… 150A 6A… 1500A 12A… 3000A 15A 150A 1500A 3000A AC O O MBX Lem Flex (15/150/3000) (EP0404A) 2 CAT III 600 V 15 mV/A 40 Hz ... 10 kHz 300 A 200 mA 0.5% FS17xx IP65 i5sPQ3 n/a One connector 2 CAT III 1000 V CAT IV 600V 0.1 mV/A 61 cm 3300 A 450 mA 2%+2% position influence 40Hz …5kHz 450mA … 15A 600mA… 150A 6A… 1500A 12A… 3000A 15A 150A 1500A 3000A AC O O MBX Lem Flex (15/150/3000) (EP0404A) 4 Phase flexiset, 4 Phase flexiset, IP41 IP65 FS17xx Output cable (m) Safety rating 15 mV/A 40 Hz ... 10 kHz 300 A 200 mA 0.5% 200 mA ... 20 A 2 A ... 200 A 20 A 200 A AC O O MBX CLAMP 20/2000A+N (EPO456A) 4 ... phase 20A/2000A Mini current clamp set i20A/200A CLAMP PQ4 0.1 mV/A 75 mV/A 40 Hz ... 10 kHz 100 A 50 mA 0.5% 200 mA ... 20 A 2 A ... 200 A 20 A 200 A AC O O MBX CLAMP 20A/200A (EPO455A) 3 ... phase 20A/200A Mini current clamp set i20A/200A CLAMP PQ3 75 mV/A 40 Hz ... 10 kHz 100 A 50 mA 0.5% 50 mA ... 5A 500 mA ... 50 A 5A 50 A AC O O MBX CLAMP 5A/50A+N (EPO453A) 4 ... phase 5A/50A Mini current clamp set i5A/50A CLAMP PQ4 Output level(s) 40 Hz ... 10 kHz 20 A 10 mA 0.5% 50 mA ... 5 A 500 mA ... 50 A 5A 50 A AC O O MBX CLAMP 5A/50A (EPO452A) 3 ... phase 5A/50A Mini current clamp set i5A/50A CLAMP PQ3 61 cm 40 Hz ... 10 kHz 20 A 10 mA 0.5% 10 mA ... 1 A 100 mA ... 10 A 1A 10 A AC 1A 10 A AC 10 mA ... 1 A 100 mA ... 10 A O O MBX CLAMP 1A/10A+N (EPO451A) 4 ... phase 1A/10A Mini current clamp set i1A/10A CLAMP PQ4 O O CURRENT CLMAPS 1A (EPO450A) 3 ... phase 1A/10A Mini current clamp set i1A/10A CLAMP PQ3 Requires battery Flex head length Usable frequency Highest current Lowest measurable current Basic accuracy (48 ... 65 Hz) 1) Cont. AC current range Fluke 1735 Fluke 174X Fluke 43X Nominal current range(s) Old Fluke model # Descript ion Fluke model number O 4 x BNC 10 mV/A 1 mV/A 0.1 mV/A 2.1 CAT III 600 V 10 Hz ... 100 kHz O 4000 A 1A 2% + 2 A O 30 A 300 A 3000 A 1 A ... 30 A 1 A ... 300 A 1 A ... 2400 A 4 ... phase 3000A Flexible current clamp set i3000 flex ... 4PK 4 x BNC 2.5 CAT III 1000 V CAT IV 600 V Clamp opening: 32 mm 10 mV/A 1 mV/A 45 Hz ... 3 kHz 1000 A 0.5 A 2% + 0.15 A 0.5 A ... 40 A 5 A ... 400 A O 40 A 400 A Single phase 400A current clamp (4 required) i400s 4 x BNC 2.5 CAT III 1000 V CAT IV 600 V 0.085 mV/A @50 Hz 61 cm 10 Hz ... 7 kHz 100 kA 30 A 1% 30 A ... 3000 A O 3000 A 4 ... phase 3000A Flexible current clamp set i430 ... flex ... 4PK 3 x BNC 2.5 CAT III 600 V Clamp opening: 15 mm 400 mV/A 40 Hz ... 5 kHz 70 A 10 mA 1% 0.01 A ... 6 A O 5A 3 ... phase 5A Current clamp set i5sPQ3 Power Quality Current Clamps Norma 4000/5000 Power Analyzers Reliable, highly accurate measurements for the test & development of power electronics Fluke Norma Series Power Analyzers The compact Fluke Norma Series Power Analyzers provide the latest measurement technology to assist engineers with the development and testing of motors, inverters, lighting, power supplies, transformers and automotive components. The Series consists of the Fluke Norma 4000 Three-Phase Power Analyzer and the Fluke Norma 5000 Six-Phase Power Analyzer. These rugged analyzers provide unmatched price performance for easy and reliable use in the field, or as a bench unit in laboratories and on test benches. Based on a patented, high-bandwidth architecture, the instruments deliver high-precision measurements of single or three-phase current and voltage, harmonics analysis, Fast Fourier Transformation (FFT) analysis, as well as calculations of power and other derived values. • Simple user interface ensures easy, intuitive operation • Unique user-configurable modular design • Simultaneous parallel acquisition of all phases • Voltage, current and power harmonics up to the 40th • Includes FFT analysis, vector diagram display, recorder function, and Digital Oscilloscope (DSO) mode • User selectable average time – from 15ms to 3600s • Expandable on-board memory for storage of measured values A unique user-configurable system design with plug-in power phases and other optional modules provides the flexibility to meet a variety of application measurement requirements. Recorded data and waveforms can be viewed clearly in the large color display and easily downloaded to a PC for analysis and report writing. Fluke Norma 4000 Fast Fourier Transformation (FFT) analysis Digital Oscilloscop (DSO) mode Vector Display Recorder function Specifications (Check the Fluke web for detailed specifications) Fluke Norma 5000 Included Accessories Number of Phases Weight Size (HxWxD) On-board Printer Display Bandwidth Basic Accuracy Sampling Rate Voltage Input Range Current Input Range (direct, not via shunt) Memory for Configurations Memory for Settings Fast Fourier Transformation (FFT) RS232 Interface PI1 Process Interface (8 analog/impulse inputs and 4 analog outputs) IEEE 488.2 /GPIB Interface (1 MBit/s Ethernet / 10 MBit/s or 100 Mbit/s) Fluke NormaView PC Software (for data download, analysis & report writing) Fluke Norma 4000 Fluke Norma 5000 1 or 3 3, 4 or 6 Approx. 5 kg Approx. 7 kg 15 cm x 23.7 cm x 31.5 cm 15 cm x 44.7 cm x 31.5 cm No Yes (optional) Color, 5.7“ / 144 mm - 320 x 240 pixel dc to 3 MHz or dc to 10MHz depending on input module 0.2%, 0.1% or 0.03% depending on input modules 0.33 MHz or 1 MHz depending on input modules 0.3 V to 1000 V 0.03 mA – 20 A depending on input module 4 MB, expandable to 128 MB 0.5 MB To the 40th harmonic Standard Optional Optional Standard Power Supply Cable, RS232 Interface and USB adaptor for Data Download, Fluke NormaView PC Software, User’s Manual, Test Certificate, and Calibration Values. Ordering Information Fluke Norma 4000 Fluke Norma 5000 Three-Phase High Precision Power Analyzer Six-Phase High Precision Power Analyzer Operating temperature: + 5 °C to 35 °C Storage temperature: - 20 °C to 50 °C Climatic class: KYG DIN 40040, maximum 85% relative humidity, non-condensing. Housing: Solid metal case Safety: EN 61010-1 / 2nd Edition, 1000 V CAT II (600 V CAT III) Two Year Warranty 89 Norma 4000/5000 Power Analyzer Accessories Power Phases Fluke Norma 4000 (rear view) The Fluke Norma 4000 Power Analyzer can be equipped with up to three power phases and the Fluke Norma 5000 Power Analyzer can be equipped with up to six power phases. Users can select the power phase best suited for their application. Specifications vary depending on the model of the power phase. Each plug-in power phase consists of a voltage and a current measurement channel. Each measuring channel is available for each basic unit. Power Phase Overview Channel Accuracy Current range Sampling rate Bandwidth 3024770 PP42 0.2% (0.1% rd + 0.1% rg) 20 A 341 kHz 3 MHz 3024812 PP50 10 A 1 MHz 10 MHz 3024820 PP54 0.1% 0.05% rd + 0.05% rg 10 A 341 kHz 3 MHz 3024835 PP64 0.03% (0.02% rg + 0.01% rg) 10 A 341 kHz 3 MHz Fluke Norma 5000 (rear view) Shunts The input modules can take up to 10 A or 20 A directly or measure current via wideband precision shunts. The available range of shunts enables measurements up to 1500 A and can be used in conjunction with all of the available input modules. 3024677 3024689 3024886 3024899 3024847 3024858 3024864 3024873 3024692 32 A Planar Shunt Cables for 32 A Planar Shunt 10 A Triaxial Shunt with Cables (0.333 ., 0 to 0.5 MHz) 30 A Triaxial Shunt with Cables (0.010 ., 0 to 0.5 MHz) 100 A Shunt with Cables (0.001 Ω, 0 to 0.5 MHz) 150 A Shunt with Cables (0.5 mΩ, 0 to 0.5 MHz) 300 A Shunt with Cables (0.1 mΩ, 0 to 1 MHz) 500 A Shunt with Cables (0.1 mΩ, 0 to 0.2 MHz) LG Shunt Cables for High Current Shunts Cables & Adaptors 3024661 3024704 Measurement Cable Set (for one power phase) Fluke Norma WYE Adaptor (external accessory box) Printer Accessories 3024650 Printer Cable for Fluke Norma 5000 (RS232-Centronics) All accessories have a two-year warranty. 90 Optional shunts for Fluke Norma Series Power Analyzers 32 A Planar Shunt Field Calibrators Fluke process calibration tools include a full range of calibrators and troubleshooting tools for instrument technicians working in the process industries. The range of process calibrators include: Documenting Process Calibrators, Multifunction Process Calibrators, single function and multifunction temperature calibrators, a variety of mA loop calibrators and a range of intrinsically safe products. 91 O 3 93 O 3 93 2 1 O 3 93 24 V O O O O 24 V O 15 V 11 kΩ 22 mA O 50 kHz 8 11 8 11 50 kHz O1 300 V 300 V 11 kΩ 110 mA 741B O 15 V 11 kΩ 22 mA O 50 kHz 8 11 8 11 24 V O O O O O O 15 V 11 kΩ 22 mA O 50 kHz 8 11 Fluke 700 pressure modules required Ranges for the internal sensor. Ranges for use of Fluke 700 pressure modules, see page 102. Record Min/Max Hold As Found/As Left results Log data Upload data to PC Remote operation Features Loop supply Hart communication Integrated hand pressure pump Electric Pump Intrinsically safe (ATEX) NIST traceable certification Warranty in years See catalog page Source/Simulate Voltage DC Resistance mA DC/% scale mA source; auto step, auto ramp Frequency Temperature: RTD types Temperature: TC types 8 11 50 kHz O1 Current AC Frequency Pressure Temperature: RTD types Temperature: TC types 300 V 300 V 11 kΩ 110 mA 300 V 300 V 11 kΩ 110 mA 50 kHz O1 743B 744 92 Model Measure Voltage DC Voltage AC (true RMS) Resistance Current DC Documenting Process Calibators 24 V O 3 94 725Ex O 3 94 O 20 V 4000 Ω 24 mA O 15 kHz 8 10 8 12 24 V/12 V O/- 10 V 3200 Ω 24 mA O 10 kHz 7 10 7 12 15 kHz O1 4000 Ω 24 mA 3200 Ω 24 mA 10 kHz O1 30V 726 30 V 725/725Ex Multifunction Process Calibrator O 3 95 24 V 7 10 10 V 3200 Ω 7 12 3200 Ω 24 mA 30 V 724 O 3 96 9 75 mV 9 75 mV 714 O 3 96 7 3200 Ω 7 3200 Ω 712 Temperature Calibrators 718Ex O 3 98 O 24 V/- O O 68,9 mbar to 20 bar / 2 to 7 bar2 24 mA 718/718Ex O 3 98 24 V O O 68,9 mbar to 345 bar2 24 mA 717 719 O 3 98 O 24 V O O O 2 bar to 7 bar2 24 mA Pressure Calibrators O 3 99 24 V 24 mA O 10 V 24 mA 10 V 715 707Ex O 3 99 24 V 24 mA O 24 mA 28 V 707/707Ex 3 100 O 100 mA 771 3 100 24 V O 24 mA O 100 mA 772 Loop Calibrators 3 100 24 V O 24 mA O 10 V 100 mA 30 V 773 O 3 99 24 V 24 mA O 24 mA 28 V 705 3 101 24 V O O O 24 mA O 1000 V 1000 V 40 MΩ 30 mA, 1A O 20 kHz 789 3 101 O O 24 mA O O 20 kHz 1000 V 1000 V 40 MΩ 30 mA, 1A 787 ProcessMeters Field Calibrator Selection Guide 740 Series Documenting Process Calibrators Calibrators as versatile as you are Fluke 743B Fluke 744 The 740 series Documenting Process Calibrators are rugged, handheld tools for the calibration and troubleshooting of process control instrumentation. These calibrators: • Calibrate temperature, pressure, voltage, current, resistance, and frequency • Simultaneously measure and source • Automatically capture calibration results • Document procedures and results to meet ISO 9000, EPA, FDA, OSHA, and other government requirements • Measure/simulate eleven types of thermocouples and eight RTDs • Store up to 8,000 readings in data logging mode (743B +744 only) • Protected against dirt, dust, and moisture; unaffected by vibration • PC interface (743B +744 only) • Operates in English, French, German, Italian, and Spanish • One and two-year calibration cycles • Four types of built-in automated calibration procedures; linear transmitter, square root devices, one and two-point limit switches 741B: A complete documenting calibrator Fluke 741B The 741B is the economical choice for plants that don’t use PCs or that require traditional paper forms. It has storage capacity for a day’s calibration and measurement data. When you’re back at the shop, recall the data on-screen to fill out calibration forms. 743B: More memory, plus a PC interface and data logging The 743B has all the capabilities of the 741B plus a PC interface that lets you download procedures, lists, and instructions created with software–or upload data for printing, archiving, and analysis. With its expanded memory, the 743B can hold a full week of calibrations and procedures. 744: Get HART-ability The Fluke 744 offers all of the capabilities of the 743B, plus the ability to calibrate, maintain, and troubleshoot HART instrumentation with just one tool. This rugged, reliable tool offers: • Integrated HART communication functions, permitting you to monitor, control, and calibrate HART instrumentation. • NiMH battery with 3500 mA hour life and battery indicator. Instrumentation Management Software The Fluke 743B and 744 are compatible with Fluke 700SW DPC/TRACK software and with software from Cornerstone, Fisher-Rosemont, Honeywell, Yokogawa, Prime Technologies and On Time Support. Included Accessories Fluke 741B/743B: TL224 Industrial Test Leads (2 sets), AC220 Test Clips (2 sets), TP220 Test Probes (1 set), BP7217 Battery Pack, BC7217 Battery Charger, Instruction Manual, NIST Traceable calibration certificate and data, three-year warranty, serial port cable (743B only), DPC/TRACK Sample Version with free PC communication utility software (743B only). Fluke 744: TL224 Industrial Test Leads (2 sets), AC220 Test Clips (2 sets), TP220 Test Probes (1 set), BP7235 NiMH Battery Pack, BC7217 Battery Charger, serial port cable, HART communications cable, DPC/TRACK Sample Version with free PC communication utility software, Instruction Manual, HART Users Manual, NIST Traceable calibration certificate and data. Specifications (Check the Fluke web for detailed specifications) Function Voltage DC Current DC Resistance Frequency Thermocouples RTDs Pressure Measure Sourcing 0.025% reading + 0.005% full scale 0.01% output + 0.005% full scale 0.01% reading + 0.015% full scale 0.01% output + 0.015% full scale 0.05% reading + 50mΩ 0.01% output + 40mΩ 0.05% 0.01 % 0.3ºC 0.2ºC 0.3ºC 0.1ºC To 0.05% of full scale. See Pressure Module specifications. Operating temperature: -10º C to 50º C Safety: CAT II 300V Battery Life: Typically over eight hours Internal Battery Pack: NiCd, 7.2V, 1700 mAh Ordering Information Fluke 741B Fluke 743B Fluke 744 700SW Battery Replacement: Via snap-shut door without opening calibrator; no tools required Weight: 1.4 kg Size (HxWxD): 236 mm x 130 mm x 61 mm Three Year Warranty Recommended Accessories Documenting Process Calibrator Documenting Process Calibrator Documenting Process Calibrator DPC/Track Software C789 See page 118 TL220 See page 110 80PK-8 See page 116 80PK-25 See page 116 700P27 See page 102 93 725/725Ex/726 Multifunction Process Calibrators More calibration power! Fluke 725 Fluke 726 Fluke 725Ex Features Simultaneous Function Capability 24.000 mA DC 24.000 mA DC with 24 V loop supply 100.00 mV DC 30.000V DC measure 20.000V DC Measure 10.000V DC Source 20.000V DC Source 15 to 3200 Ohms 5 to 4000 Ohms Thermocouple J, K, T, E, R, S, B, M, L, U, N, XK, BP RTD Cu 10, Ni120; Pt100 (392); Pt100 (JIS); Pt100, 200, 500, 1000 (385) Pressure (requires Fluke 700 PXX Modules) Frequency; 10 kHz; (15 kHz) Channel A Channel B M M M or S M or S M M or S M or S M or S M or S M or S M or S M 725/725Ex/726 Multifunction Process Calibrators 726 Precision Multifunction Process Calibrator • Two separate channels; measure, source and view process signals simultaneously • Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters • Source/simulate volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters • Measure or *source pressure using any of 29 Fluke 700Pxx Pressure Modules • Source mA with simultaneous pressure measurement to conduct valve and I/P tests • Perform fast linearity tests with auto step and auto ramp features • Power transmitters during test using 24 V loop supply and simultaneous mA measurement • Store frequently-used test setups for later use • For 725Ex version see also page 106 and 107 *Pressure pump required Additional features: • More precise measurement and calibration source performance, accuracies of 0.01% • Transmitter error% calculation • Memory storage for up to 8 calibration results • Frequency totalizer and frequency pulse train source mode for enhanced flowmeter testing • HART mode inserts 250 ohm resistor in mA measure and source for compatibility with HART instrumentation • Integrated pressure switch test allows you to capture the set, reset and deadband of a switch • Custom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement Function Measure or Source Voltage Range or Type Resolution Accuracy Notes 0 to 100 mV 725: 0 to 10V (source) 0 to 20V (source) 725/726: 0 to 30V (measure) 0 to 24 0.01 mV 0.001 V 0.001 V 0.001 V 0.001 mA 0.01% 0.02% Rdg + 2 LSD Max load, 1 mA 0.01%; 0.02% Rdg +2 LSD Max load, 725/726: 1000Ω 725Ex: 250Ω mV (TC terminals) -10.00 mV to +75.00 mV 0.01 mV Ohms 15Ω to 3200Ω 5Ω to 4000Ω 2.0 to 1000 CPM 1 to 1100 Hz 1.0 to 10.0 kHz 10.0 to 15.0 kHz 0.01Ω to 0.1Ω 0.1 CPM 1 Hz 0.1 kHz 0.1 kHz 0.01% 0.02% of range + 1 LSD 0.10Ω to 1.0Ω 0.015% ±0.05% ±0.05% ±0.25% ±0.05% mA Hz - CPM M used as S M or S M = Measure S = Source/Simulate Unique 726 features are in bold 725Ex: ATEX cerfified (Ex ATEX II IG EEX 1a IIB 171°C) Included Accessories TL75 Test Leads, AC72 Test Clips, one pair of stackable test leads, user’s Manuals on CD-ROM (725Ex also includes CCD control drawing, Statement of Quality Assurance Practices, NIST Traceable calibration certificate) Specifications Unique 726 features are in bold Loop Supply N/A 10% T/C 725/726: 24 V DC 725Ex: 12 V DC J, K, T, E, L, N, U, XK 0.1 ºC, 0.1 ºF T/C B, R, S, BP 1 ºC, 1 ºF RTDs Cu (10), Ni 120 (672) Pt 100, 200, 500, 1000 (385) Pt 100 (3916), Pt 100 (3926) 0.01 ºC 0.01 ºF to 0.7 ºC to 0.2 ºC to 1.7 ºC to 1.2 ºC to 0.15 ºC Maximum voltage: 30V Operating temperature: 10°C to 55°C Safety: CSA C22.2 No. 1010.1:1992 EMC: EN50082-1:1992 and EN55022: 1994 Class B 0.1 ºC, 0.1 ºF Source; 5V p-p 1V - 20 V p-p squarewave, -0.1 V offset to 0.2 ºC Size (HxWxD): 200 mm x 96 mm x 47 mm Weight: 0.65 kg Battery: Four AA alkaline batteries. Battery life: 25 hours typical; battery door Warranty: Three years Recommended Accessories (Not for hazardous zones) Ordering Information 94 Fluke 725 Multifunction Process Calibrator Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator Fluke 726 Precision Multifunction Process Calibrator C125 See page 118 TL220 See page 110 80PK-27 See page 116 TPAK See page 120 700P27 See page 102 724 Temperature Calibrator The temperature solution The Fluke 724 Temperature Calibrator is a powerful yet easy-to-use calibrator. Use the measure and source functions to test and calibrate almost any temperature instrument. • Easy to read dual display lets you view input and output simultaneously • Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters • Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters • Perform fast linearity tests with 25% and 100% steps • Execute remote tests with auto step and auto ramp • Power transmitters during test using loop power supply with simultaneous mA measurement • Store frequently-used test setups for later use Features Simultaneous Function Capability 24.000 mA DC 24.000 mA DC with 24V loop supply 100.00 mV DC 30.000V DC Measure 20.000V DC Measure 10.000V DC Source 0 to 3200 Ohms Thermocouple J, K, T, E, R, S, B, L, U, N RTD Ni120; Pt100 (3926); Pt100 (JIS); Pt100, 200, 500, 1000 (385) Fluke 724 M = Measure Channel A Channel B M M M or S M M or S M or S M or S M or S S = Source/Simulate Specifications Function Measure or Source Voltage Range Resolution Accuracy Notes 0 to 100 mV 0.01 mV 0.02% Rdg + 2 LSD Max load, 1 mA mA (measure) 0 to 10V (source) 0 to 30V (measure) 0 to 24 mA 0.001 V 0.001 V 0.001 mA 0.02% Rdg +2 LSD Max load, 1000Ω mV -10.00 mV to +75.00 mV 0.01 mV Resistance 0Ω to 3200Ω (measure) 15Ω to 3200Ω (source) 24V DC J, K, T, E, L, N, U B, R, S Ni120 (672) Pt 100, 200, 500, 1000 (385) Pt 100 (3916) Pt 100 (3926) Loop Supply Thermocouples Thermocouples RTDs Included Accessories TL75 Test Leads, AC72 Test Clips, one pair of stackable test leads. Maximum voltage: 30V Operating temperature: -10°C to 55°C Safety: CSA C22.2 No. 1010.1:1992 EMC: EN50082-1:1992 and EN55022: 1994 Class B 0.01Ω to 0.1Ω 0.025% of range + 1 LSD 0.10Ω to 1.0Ω N/A 0.1 ºC 1 ºC 0.1 ºC 10% to 0.7 ºC to 1.4 ºC to 0.2 ºC Size (HxWxD): 200 mm x 96 mm x 47 mm Weight: 0.65 kg Battery: Four AA alkaline batteries Battery life: 25 hours typical; battery door Three Year Warranty Ordering Information Fluke 724 Temperature Calibrator Recommended Accessories C25 See page 118 TL220 See page 110 TL81A See page 109 80PK-25 See page 116 80PK-3A See page 116 95 712/714 Temperature Calibrators The clear choice The Fluke 710 Series Process Calibrators offer clear new choices in single-function calibrators. Whatever you want to measure - temperature, pressure or basic electrical parameters - you’ll find one of these easy-to-carry handheld tools gives you exactly the functions you need. They combine the rugged, ready-for-action package of the proven Fluke 80 Series DMMs with the easy-to-use pushbutton operation of the multifunction Fluke 740 Series Documenting Process Calibrators. These calibrators are EMI tolerant, dust and splash resistant, and have a removable battery door for quick battery changes. Fluke 714 712 RTD Calibrator • Measure temperature from RTD output • Simulate RTD output • Rosemount pulsed RTD transmitter compatible • Operates with seven types of RTDs • Measure additional RTDs using Ohms measurement function • Simulate additional RTDs using Ohms source function • °F or °C selectable • Four shrouded banana jacks 714 Thermocouple Calibrator • Measure temperature from TC output • Simulate TC output • Operable with nine types of thermocouples • Calibrate linear TC transmitter with mV source function • Selectable °F or °C • Thermocouple mini-jack termination • Available as accessories; Fluke 700 TC1 and TC2 Thermocouple Mini-plug Kits Fluke 712 Specifications Model Fluke 712 Fluke 714 Function Measure/ simulate RTD Range -200 to 800ºC (Pt 100) Resolution 0.1ºC, 0.1ºF Accuracy 0.33ºC, 0.6ºF (Pt 100) Measure/ simulate Resistance Measure/ simulate Thermocouple 15 Ω to 3200 Ω 0.1 Ω 0.1 Ω to 1 Ω -200 to 1800ºC, depending on type (K, -200 to 1370ºC) -10 to 75 mv 0.1–C or ºF (1ºC or ºF; BRS) 0.3ºC to 10 μV 0.01 mV 0.025% + 1 count Measure/ simulate mV Included Accessories Yellow Holster (H80M excl. TPAK), TL75 Test Leads and AC72 Alligator Clips (excluding model 714), single 9V alkaline battery and Instruction Sheet (14 languages) Maximum voltage: 30 V Operating temperature: -10°C to 55°C Safety: CSA C22.2 No. 1010.1:1992 EMC: EN50082-1:1992 and EN55022: 1994 Class B Notes Pt; 100, 200, 500, 1000 (385); Pt 100 (3926); Pt 100 (3916) JIS; Ni 120 (672) 9 TC types: J K T E R S B per NIST 175 and ITS-90, L U per DIN 43710 and IPTS-68 Size (HxWxD): 201mm x 98 mm x 52 mm Weight: 0.6kg Battery: 9V alkaline Battery Life: 4 to 20 hours, typical, depending on functions used Three Year Warranty Ordering Information Fluke 712 Fluke 714 RTD Calibrator Thermocouple Calibrator Recommended Accessories C25 See page 118 96 C550 See page 118 TL970 See page 109 TL220 (714) See page 110 80PK-24 (714) See page 116 9140 Series Field Metrology Wells 4180 Series Infrared Calibrators Field Metrology Wells and infrared calibration targets Fluke 9142/9143/9144 9142, 9143, 9144 Field temperature calibration with precision and speed 4180/4181 IR Calibrators True metrology solution for infrared Calibration The Fluke 9140 series Field Metrology Wells extend high performance portable temperature calibration to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance. Now it’s easy to increase your IR temperature measurement accuracy in the lab or the field with the new 4180/81 Precision Infrared Calibrators from Fluke’s Hart Scientific division. Offering a broad temperature covered by three models you can easily cover varied contact temperature probe workloads between -25 ºC to 660 ºC. They are quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. Adding the process option means there is no need to carry additional tools into the field. The optional built-in two-channel readout measures resistance, voltage, and 4–20 mA current with 24V loop power. Fluke 4180/4181 • Lightweight, portable, and fast • Cool to –25 °C in 15 minutes and heat to 660 °C in 15 minutes • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current • On-board automation and documentation • Metrology performance in accuracy, stability, uniformity, and loading Included Accessories 914x: 9930 Interface-it Software, Report of Calibration, Test leads (P Version Only), 6-pin DIN Connector for Reference Probe (P Version Only) Their accredited calibrations from Hart’s IR laboratory help to ensure traceable, consistent measurements accurate to +0.25 ºC. Select from eight preconfigured Fluke thermometer settings or set up your own. The large 152 mm (6 inch) target helps eliminate errors. So whether you’re measuring from -15 ºC to 120 ºC (4180) or from 35 ºC to 500 ºC (4181) you’ll get a 4:1 TUR. • High performance, designed for industrial use • Guaranteed accuracy specifications • Excellent stability and uniformity • Large 152 mm targets capture peripheral vision of IR thermometer • Portability and speed for field use including convenient bail handle • Simulates individual IR thermometer emissivity settings • No difficult infrared calculations • Fluke and Raytek thermometer calibration points can be loaded directly into the calibrator for convenience • Calibrated in accredited infrared laboratory by Hart Scientific, the experts in temperature calibration • At least 4 times more accurate than most IR thermometers • Calibration includes uncertainties from surface heat loss and emissivity Ordering Information Fluke 4180 Precision Infrared Calibrator, –15 °C to 120 °C Fluke 4181 Precision Infrared Calibrator, 35 °C to 500 °C Fluke 4180-CASE Carrying Case, 4180, 4181 Fluke 4180-DCAS Carrying Case with wheels, 4180, 4181 Fluke 9142-X Fluke 9143-X Fluke 9144-X Field Metrology Well, Low Temp Field Metrology Well, Mid Temp Field Metrology Well, High Temp Add -P to order optional Process option (914X-X-P). X represents insert type, A, B, C, D, E or F Specifications 9142 9143 9144 4180 Temp Range –25 °C to 150 °C 33 °C to 350 °C 50 °C to 660 °C –15 °C to 120 °C 35 °C to 500 °C Stability ±0.01 °C Full Range ±0.2 °C at 250 °C ±0.01 °C Full Range ±0.1 °C at 0 °C ±0.1 °C at 35 °C Target Size diameter Emissivity Range NIST Accredited Calibration N/A ±0.03 °C at 50 °C ±0.04 °C at 420 °C ±0.05 °C at 660 °C ±0.02 °C at 50 °C ±0.05 °C at 420 °C ±0.15 °C at 660 °C N/A ±0.05 °C at 0 °C Uniformity ±0.02 °C at 33 °C ±0.02 °C at 200 °C ±0.03 °C at 350 °C ±0.01 °C at 33 °C ±0.015 °C at 200 °C ±0.02 °C at 350 °C N/A 152.4 mm N/A N/A N/A 152.4 mm diameter Preset to 0.95 YES YES YES YES YES 9142/9143/9144: Size (HxWxD): 290 x 185 x 295 mm Weight: 9142: 8.2 kg, 9143: 7.3 kg, 9144: 7.7 kg One Year Warranty 4181 Preset to 0.95 4180/4181 Size (HxWxD): 241 x 356 x 241 mm Weight: 4180: 9.1 kg, 4181: 9.5 kg One Year Warranty For the complete line of Fluke heat sources check the Fluke web at www.fluke.eu 97 717/718/718Ex/719 Pressure Calibrators Pump up the pressure Fluke 719 Fluke 717 717 Pressure Calibrators 718 Pressure Calibrators • Measure pressure, 0.05% of full scale with internal sensor - 1/8 NPT pressure fitting - Compatible with non-corrosive gasses and liquids • Pressure measurement to 700 bar using any of the Fluke-700Pxx Pressure Modules • Wide range of selectable measurement units for pressure • Current measurement with 0.015% accuracy and 0.001mA resolution • Simultaneous pressure and current measurement for easy P/I testing • 24 volt loop power supply • Zero, Min-Max, Hold and Damping functions • Pressure switch test captures set, reset and deadband values Same features as Fluke 717 plus: • Newly designed built-in pressure/ vacuum hand pump with vernier and bleed valve helps protect the pump from damage and is easier to clean For 718Ex Intrinsically Safe Pressure Calibrator see chapter on Ex products in this catalog. 719 Electric Pressure Calibrator Same features as Fluke 717 plus: • Electric pump for one handed operation • mA source for calibrating I/P devices and 4-20 mA I/O • Best in class pressure measurement accuracy of 0.025% Specifications Fluke 718Ex Fluke 718 Included Accessories Fluke 717, 718, 718Ex and 719: Yellow Holster (718Ex red holster), TL75 Test leads, AC72 Alligator Clips, Single 9V alkaline battery (two 9V batteries in 718 and 719), User manual on CD ROM. 719 also includes: Push fit connectors, Translucent test hose. Ordering Information Fluke 719 30G Fluke 719 100G Fluke 718 1G Fluke 718 30G Fluke 718 100G Fluke 718 300G Fluke 718Ex 30G 98 Electric Pressure Calibrator Electric Pressure Calibrator Pressure Calibrator Pressure Calibrator Pressure Calibrator Pressure Calibrator Intrinsically Safe Pressure Calibrator Fluke 718Ex 100G Intrinsically Safe Pressure Calibrator Fluke 717 1G Pressure Calibrator Fluke 717 30G Pressure Calibrator Fluke 717 100G Pressure Calibrator Fluke 717 300G Pressure Calibrator Fluke 717 500G Pressure Calibrator Fluke 717 1000G Pressure Calibrator Fluke 717 1500G Pressure Calibrator Fluke 717 3000G Pressure Calibrator Fluke 717 5000G Pressure Calibrator Model 719 30G 719 100G 718 1G 718 30G 718 100G 718 300G 717 1G 717 30G 717 100G 717 300G 717 500G 717 1000G 717 1500G 717 3000G 717 5000G Range -850 mbar to 2.4 bar -850 mbar to 8 bar -68.9 mbar to 68.9 mbar -850 mbar to 2 bar -850 mbar to 7 bar -850 mbar to 20 bar -68.9 mbar to 68.9 mbar -850 mbar to 2 bar -850 mbar to 7 bar -850 mbar to 20 bar 0 mbar to 34.5 bar 0 mbar to 69 bar 0 bar to 103.4 bar 0 bar to 207 bar 0 bar to 345 bar Resolution 0.1 mbar 1 mbar 0.001 mbar 0.1 mbar 0.1 mbar 1 mbar 0.001 mbar 0.1 mbar 0.1 mbar 1 mbar 1 mbar 1 mbar 0.01 bar 0.01 bar 0.01 bar Over Pressure Over pressure 2xFS Over Pressure 2xFS Over Pressure 5xFS Over Pressure 2xFS Over Pressure 2xFS Over Pressure 375 PSI, 25 bar Over Pressure 5xFS Over Pressure 2xFS Over Pressure 2xFS Over Pressure 375 PSI, 25 bar Over Pressure 2xFS Over Pressure 2xFS Over Pressure 2xFS Over Pressure 2xFS Over Pressure 2xFS For Fluke 717/718/719 models: Supported Pressure Units; psi, in. H 2O(4°C), in. H2O(20°C), cm H2O(4°C), cm H2O(20°C), bar mBar, kPa, inHg, mmHg, kg/cm2 Functions: Zero, Min, Max, Hold, Damp functions Max. Voltage: 30 V Operating temperature: -10°C to 55°C Safety: CSA C22.2 No. 1010.1:1992 EMC: EN50082-1:1992 and EN55022:1994 Class B Fluke 717: For use with non corrosive gasses and liquids Fluke 718/719: For use with non corrosive gasses 717 Size (HxWxD): 201 mm x 98 mm x 52 mm Weight: 0.6 kg Three Year Warranty 719 Size (HxWxD): 210 mm x 87 mm x 60 mm Weight: 0.912 kg Three Year Warranty (Pump one year) 718/718Ex Size (HxWxD): 216 mm x 94 mm x 66 mm Weight: 0.992 kg Warranty: Three years Recommended Accessories (Not for hazardous zones) C43 (718) See page 118 C125 (717) See page 118 TL220 See page 110 700P27 See page 102 700 LTP-1 See page 102 705/707/707Ex/715 Loop Calibrators 4-20 mA, source, measure, simulate 705 Loop Calibrator 715 Volt/mA Calibrator • Simultaneous mA and % • mA accuracy of 0.02% • Measure, source and simulate mA • Push button 25% steps for fast, easy linearity checks • “Span Check” for fast confirmation of zero and span • Selectable slow ramp, fast ramp, and step function • 24 volt internal loop supply • 0 - 20 mA or 4 - 20 mA default start up modes • Measure loop current (0-20 mA, 4-20 mA) signals with 0.015% accuracy and 0.001 mA resolution • Measure voltage output process signals from PLCs, transmitters • Source or simulate 24 mA loop current • Source voltage to 100 mV or 10 V • 24 V loop supply with simultaneous current measurement 707 Loop Calibrator Fluke 705 Fluke 715 • Features of the Fluke 705 • “Quick Click” detented rotary knob for one handed operation • Higher accuracy: 0.015% • Mains Voltage Input protection • 250 Ohm loop resistance for with Hart instrumentation 707Ex Intrinsically Safe Loop Calibrator • Same features as Fluke 707 • For use in explosion endangered areas • ATEX certified ( II 2 G Eex ia IIC T4) Specifications Functions Voltage measurement Range Resolution Accuracy Current measurement Range Resolution Accuracy Fluke 707 Current sourcing Range Accuracy Drive capability Fluke 707Ex Loop power while measuring mA Voltage sourcing Display current and % of span Auto step, auto ramp Span Check 1 705/707/707 Ex 715 0-28 V DC 1 mV 705: 0.025% Rdg + 2 LSD 707/707Ex: 0.015% Rdg + 2 LSD 0-200 mV, 0-20 V 10 μV 1 mV 0.01% Rdg + 2 LSD 0-24 mA 0.001 mA 705: 0.025% Rdg + 2 LSD 707/707Ex: 0.015% Rdg + 2 LSD 0-24 mA 0.001 mA 0.015% 0-20 mA or 4-20 mA1 705: 0.025% Rdg + 2 LSD 707/707Ex: 0.015% Rdg + 2 LSD 705: 1000 Ω @ 24 mA 707: 1200 Ω @ 24 mA 707Ex: 700 Ω 20 mA 24 V N/A Yes Yes Yes 0-20 mA or 4-20 mA1 0.015% + 2 LSD 1000 Ω @ 24 mA 24 V 0-100 mV or 0-10 V mA or % Yes Yes will over-range to 24 mA Included Accessories Fluke 705/707: C10 Yellow Holster, TL75 Test Leads, AC72 Alligator Clips, Single 9V alkaline battery, Instruction Sheet Fluke 707Ex: Red Ex-holster, Fluke TL75 Test Leads, AC72 Alligator Clips, Single 9V alkaline battery, Instruction Sheet Fluke 715: Yellow Holster (H80M excl. TPAK), TL75 Test Leads and AC72 Alligator Clips, Single 9V alkaline battery, Instruction Sheet Fluke 705, 707, 707Ex Maximum voltage: 30 V (28 V - 707Ex) Operating temperature: -10 to 55°C Safety: CSA C22.2 No. 1010.1: 1992 EMC: EN50082-1:1992 and EN55022: 1994 Class B Size (HxWxD): 164 mm x 75 mm x 47 mm; Weight: 0.35 kg Battery: One 9 V alkaline Battery life: 18 hours typical, at 12 mA Three Year Warranty 715 Size (HxWxD): 201 mm x 98 mm x 52 mm Weight: 0.6 kg Battery: One 9V alkaline Battery life: 4 to 20 hours Three Year Warranty Ordering Information Fluke 705 Fluke 707 Fluke 707Ex Fluke 715 Loop Calibrator Loop Calibrator Intrinsically Safe Loop Calibrator Volt/mA Calibrator C12A (705/707) See page 118 C25 (715) See page 118 TL220 See page 110 TP920 See page 109 T PAK (715) See page 120 99 771, 772 and 773 mA Process Clamp Meters mA measurements without breaking the loop. Save time. Save money. Fluke 771, 772 and 773 Fluke 773 • Measure 4 to 20 mA signals without ”breaking the Loop,” save time and money troubleshooting 4 to 20 mA signals • DC voltage measurement to verify 24 V power supplies or voltage I/O signals • Source dc voltage to test voltage input devices • Scaled mA output signal enables a logging DMM (289) to record 4 to 20 mA signal without breaking the loop • mA in/out: simultaneously source a mA signal while measuring a mA signal with the clamp Fluke 772 and 773 • Source 4 to 20 mA signals for testing control system I/O or I/Ps • Simulate 4 to 20 mA signals for testing control system I/O • Measure 4 to 20 mA signals with incircuit measurement • Power a transmitter with the 24 V loop power supply • Automatically ramp and step change the 4 to 20 mA output for remote testing Fluke 771 Features Fluke 772 New 771 O mA measure w/jaw mA measure In circuit mA source mA sim Loop power 24 V DCV source 0-10 V DCV measure 0-30 V Scaled mA output to mA input mA in/out 771, 772, 773 772 and 773 Fluke 771: soft carrying case and user’s manual Fluke 771 + 772: plus TL75 test leads, AC72 alligator clip set and TL940 mini-hook test lead set Ordering Information Fluke 771 Fluke 772 Fluke 773 100 Milliamp Process Clamp Meter Milliamp Process Clamp Meter Milliamp Process Clamp Meter 773 O O O O O O O O O Specifications Fluke 773 Included Accessories 772 O O O O O Function mA measurement Resolution and range 0 to 20.99 mA 21.0 mA to 100.0 mA Accuracy 0.2 % + 5 counts 1 % + 5 counts mA measurement 0 to 24.00 mA 0.2 % + 2 counts 772 and 773 mA source 0 to 24.00 mA 0.2 % + 2 counts 772 and 773 mA simulate 0 to 24.00 mA 0.2 % + 2 counts 773 Voltage source 0 to 10.00 V dc 0.2 % + 2 counts 773 Voltage measure 0 to 30.00 V dc 0.2 % + 2 counts Size (HxWxD): 771: 212 mm x 59 mm x 38 mm 772 + 773: 248 mm x 76 mm x 41 mm Weight: 771: 0.26 kg 772 + 773: 0.42 kg Battery: 771: 2x 1.5V Alkaline, IEC LR6 772 + 773: 4x 1.5V Alkaline, IEC LR6 Notes Measured by clamp Measured in series with test jacks Maximum mA drive: 24 mA into 1,000 ohms Maximum voltage 50 V dc 2 mA maximum drive current Battery Life: 771: 20 hours typical 772 + 773: 12 hours @ 12 mA source into 500 ohms IP Rating: IP 40 Warranty: 3 years, 1 year on mA clamp accessory and cable 787/789 ProcessMeters Double your power The Fluke 787 and 789 ProcessMeters combine a Digital Multimeter and a Loop Calibrator in one rugged handheld tool, giving process technicians double the power. The Fluke 789 has a built-in 24 V loop supply which reduces the need for taking a separate power supply when doing offline transmitter testing. The IR communication port of the Fluke 789 allows data to be logged to optional FlukeView Software for graphical analysis and reporting. Features Fluke 787 Fluke 789 787 O O O DMM and Loop Calibrator in one tool Precision 1000 V, 440 mA True RMS Digital Multimeter DC current source and Loop Calibrator 24 V Loop power supply Min/Max / Average / Hold / Relative Modes Diode Test and Continuity Beeper Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp Simultaneous mA and % of scale read-out Externally accessible battery / fuses HART mode setting with loop power and a built-in 250 Ω resistor 0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span check Infrared I/O serial port O O O O O/- 789 O O O O O O O O O/O O O O Specifications 787 True RMS Included Accessories 787: Yellow Holster (H80M excl. TPAK), TL75 Hard Point Test Lead Set plus AC72 Alligator Clips, one 9V battery, user manual 789: TL71 Test Lead Set plus AC72 Alligator Clips, four 9V AA alkaline batteries, user manual and quick reference guide. Ordering Information Fluke 787 Fluke 789 FVF-SC2 ProcessMeter ProcessMeter FlukeView Forms Software including interface cable Voltage measurements Range Resolution Accuracy Current measurement Range Resolution Accuracy Current Sourcing Range Accuracy Other specifications Max drive capability Loop power Resistance measurement Frequency Continuity Span Check 789 0-1000 V AC or DC 0.1 mV to 1.0 V 0.1% Rdg+1 LSD (V DC) 0-1000 V AC or DC 0.1 mV to 1.0 V 0.1% Rdg+1 LSD (V DC) 0-1 A 1 mA 0.2%+2 LSD 0-1 A 1 mA 0.2%+2 LSD 0-30 mA 0.001 mA 0.05%+2 LSD 0-30 mA 0.001 mA 0.05%+2 LSD 0-20 mA or 4-24 mA 0.05% of span 0-20 mA or 4-24 mA 0.05% of span 500 Ω N/A To 40 MΩ, 0.2%+1 LSD To 19.999 kHz, 0.005%+1 LSD Beeps for resistance < 100 Ω No 1200 Ω 24 V To 40 MΩ, 0.2%+1 LSD To 19.999 kHz, 0.005%+ LSD Beeps for resistance < 100 Ω Yes Maximum voltage: 1000 V Operating temperature: -20 to 55ºC 787 Size (HxWxD): 201 mm x 98 mm x 52 mm Weight: 0.642 kg Battery: One 9 V alkaline Battery life: 12 to 50 hours typical Three Year Warranty 789 Size (HxWxD): 203 mm x 100 mm x 50 mm Weight: 0.6 kg Battery: Four AA alkaline batteries Battery life: 14 to 140 hours typical Three Year Warranty Recommended Accessories C125 See page 118 TL220 See page 110 80T-150U See page 116 i400 See page 114 i410 See page 115 101 Field Calibrator Accessories Fluke 700 Series Pressure Modules • Ranges from 2.5 mbar to 700 bar. • Gage, differential, dual (compound), absolute and vacuum modules • Very high accuracy: up to 0.025% FS • Full-accuracy performance for 0°C to 50°C • Pressure readings update twice per second, and may be displayed in up to 11 different units Model Differential 700P00 700P01/700P01Ex 700P02 700P22 700P03 700P23 700P04 700P24/700P24Ex Gage 700P05/700P05Ex 700P06/700P06Ex 700P27/700P27Ex 700P07 700P08 700P09/700P09Ex Absolute 700PA3 700PA4/700PA4Ex 700PA5 700PA6 Vacuum 700PV3 700PV4 Dual 700PD2 700PD3 700PD4 700PD5 700PD6 700PD7 High 700P29/700P29Ex 700P30 700P31 • Compatible with Fluke 717, 718, 725 and 74x series. • Rugged cases protect the modules from harsh environments • All modules include NIST traceable certificate and test data • ATEX certified Ex versions available ( II 1 Eex ia IIB T4) Range (approx.) Resolution uncertainty (23 ± 3°C) (FS) Reference High side media Low side media Fitting material Max overpressure2) 2.5 mbar 25 mbar 70 mbar 70 mbar 340 mbar 340 mbar 1000 mbar 1001 mbar 0.001 mbar 0.01 mbar 0.007 mbar 0.007 mbar 0.01 mbar 0.01 mbar 0.1 mbar 0.1 mbar 0.3 % 0.2 % 0.15 % 0.1 % 0.05 % 0.025 % 0.025 % 0.025 % Dry 1) Dry Dry 316 SS Dry 316 SS Dry 316 SS Dry Dry Dry Dry Dry Dry Dry Dry 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS 30x 3x 3x 3x 3x 3x 3x 3x 2 bar 7 bar 20 bar 34 bar 70 bar 100 bar 0.1 mbar 0.7 mbar 1 mbar 1 mbar 7 mbar 10 mbar 0.025 % 0.025 % 0.025 % 0.025 % 0.025 % 0.025 % 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS N/A N/A N/A N/A N/A N/A 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS 3x 3x 3x 3x 3x 2x 340 mbar 1000 mbar 2 bar 7 bar 0.01 mbar 0.1 mbar 0.1 mbar 0.7 mbar 0.05 % 0.05 % 0.05 % 0.05 % 316 SS 316 SS 316 SS 316 SS N/A N/A N/A N/A 316 SS 316 SS 316 SS 316 SS 3x 3x 3x 3x -340 mbar -1000 mbar 0.01 mbar 0.1 mbar 0.04 % 0.04 % 316 SS 316 SS Dry Dry 316 SS 316 SS 3x 3x ± 70 mbar ± 340 mbar ±1000 mbar -1000/+2000 mbar -1000 mbar/+6.9 bar -1000 mbar/+13.8 bar 0.007 mbar 0.01 mbar 0.1 mbar 0.1 mbar 1 mbar 1 mbar 0.15 % 0.04 % 0.025 % 0.025 % 0.025 % 0.04 % 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS Dry Dry Dry N/A N/A N/A 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS 3x 3x 3x 3x 3x 3x 200 bar 340 bar 700 bar 0.01 bar 0.01 bar 0.07 bar 0.05 % 0.05 % 0.05 % C276 C276 C276 N/A N/A N/A C276 C276 C276 2x 2x 1.5x 1)“Dry” indicates dry air or non-corrosive gas as compatible media. “316 S S” indicates media compatible with Type 316 Stainless Steel. “C276” indicates media compatible with Hastelloy C276. 2)Maximum overpressure specification includes common mode pressure. Other accessories 700LTP-1 Low-pressure Test Pump 700HTH-1 Hydraulic Test Hose • For low pressure applications • Vacuum to -13 psi / -.90 bar • Pressure to 100 psi / 6.9 bar • With fine-control, adjustable relief valve and slow bleed capability • Hydraulic test hose is a 10,000 psi, 690 bar 700PTP-1 Pneumatic Test Pump-1 • Handheld pressure pump • Pressures up to 600 psi, 40 bar 700HTP-1 Hydraulic Test Pump • Pressures up to 10,000 psi/690 bar. Fluke 700LTP-1 102 Fluke 700PTP-1 700PRV-1 Pressure Relief Valve • Pressure relief valve for 700HTP-1 • Adjustable from 725 to 5800 PSI (50 to 200 bar) 700ILF In-Line Filter for the Fluke 718 700PCK Pressure Module Calibration Kit BP7235 NiMH Battery Pack BE9005 Battery Eliminator Vibration Tester With the Fluke 810 Vibration Tester you will be able to control unplanned downtime, prevent recurring problems, set repair priorities and manage your resources with an entirely new approach to vibration testing. In three quick, easy steps, the new Fluke 810 helps you locate and diagnose common mechanical problems and prioritize their repair actions. The combination of powerful algorithms and a database of real-world measurement experience make the Fluke 810 the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now. 103 810 Vibration Tester New Motor diagnosis and repair in three simple steps The Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now. The unique diagnostic technology helps you quickly identify and prioritize mechanical problems, putting the expertise of a vibration analyst in your hands. Use the vibration tester to: Fluke 810 Set-up • Troubleshoot problem equipment and understand the root cause of failure • Survey equipment before and after planned maintenance and confirm the repair • Commission new equipment and ensure proper installation • Provide quantifiable proof of equipment condition and drive investment in repair or replacement • Prioritize and plan repair activities and operate more efficiently • Anticipate equipment failures before they happen and take control of spare parts inventories • Train new or less-experienced technicians and build confidence and skill across the team Measure Features and benefits • On-board identification and location of the most common mechanical faults (bearings, misalignment, unbalance, looseness) focus maintenance efforts on root cause, reducing unplanned downtime • Fault severity scale with four severity levels help you prioritize maintenance work • Repair recommendations advise technicians on corrective action • On-board context sensitive help provide real-time tips and guidance to new users • 2 GB expandable on-board memory provide enough space for your machinery’s data • Self-test functions ensure optimal performance and more time on the job • Laser tachometer for accurate machine running speed promotes confident diagnoses • Tri-axial accelerometer reduces measurement time by 2/3 over single axis accelerometers • Viewer PC Software expands data storage and tracking capacity • Color LCD display and intuitive multilingual, icon-based user interface promote use right out of the box Specifications (Check the Fluke web for detailed specifications) Diagnose Language support: eng, ger, fre, ita, spa, por Included Accessories Tri-axial TEDS accelerometer, accelerometer magnet mount, accelerometer mounting pad kit with adhesive, accelerometer quick disconnect cable, laser tachometer and storage pouch, smart battery pack with cable and adapters, shoulder strap, adjustable hand strap, Viewer PC application software, mini-USB to USB cable, getting started guide, illustrated quick reference guide, users manual CD-ROM, instructional training CDROM, hard carrying case. Ordering Information 104 Fluke 810 Vibration Tester Diagnostic specifications Standard faults Unbalance, looseness, misalignment and bearing failures Analysis for Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/ lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles Machine rotational 200 rpm to 12000 rpm speed range Diagnosis details Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra Electrical specifications Ranging Automatic A/D converter 4 channel, 24 bit Usable bandwith 2 Hz to 20 kHz Sampling 51.2 kHz Digital signal Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, processing functions windowing, FFT, and averaging Sampling rate 2.5 kHz to 50 kHz Dynamic range 128 dB Amplitude accuracy ±0.1 dBV FFT resolution 800 lines Spectral windows Hanning Frequency units Hz, orders, cpm Amplitude units in/sec, mm/sec, VdB (US), VdB (Europe) Non-volatile nemory SD micro memory card, 2 GB internal + user accessible slot for additional storage Battery type: Lithium-ion, 14.8 V 2.55 Ah Size (HxWxD): 186 x 267 x 70 Weight: 1.9 kg Warranty: Three years on tester One year on sensor and tachometer ATEX Certified Test Tools The Fluke line of intrinsically safe tools is designed to meet the needs of technicians working in and around hazardous areas. The tools are ideal for environments in chemical plants, petro-chemical plants, oil platforms, refineries and other locations where risk of explosion exists. The products are easily recognizable from standard Fluke products by their lighter grey colour and red holster. 105 A brief look at ATEX Intrinsic safety is a protection standard employed in potentially explosive atmospheres. Devices that are certified as “intrinsically safe” are designed to be unable to release sufficient energy, by either thermal or electrical means, to cause ignition of flammable material (gas, dust/ particulates). What is “Intrinsically Safe”? Intrinsically safe standards apply to all equipment that can create one or more of a range of defined potential explosion sources: • Electrical sparks • Electrical arcs • Flames • Hot surfaces • Static electricity • Electromagnetic radiation • Chemical reactions • Mechanical impact • Mechanical friction • Compression ignition • Acoustic energy • Ionizing radiation What industries are intrinsically safe products designed for? • Petro-chemical • Oil platforms and refineries • Pharmaceutical • Bulk materials (e.g. grain) • Mining • Pipelines • Any environment where explosive gases are present What is ATEX? The primary intrinsically safe standard has been set in the European Union with the 9/94/EC Directive, commonly called ATEX (“Atmosphères Explosibles,” French for explosive atmospheres). The stated goal of the guidelines is to “help ensure the free movement of products in the European Union” by “minimizing the number of safeguard clause applications, at least those originating from divergent interpretations The ATEX rules have been in place as a voluntary standard since 1 March 1996. The rules are mandatory on electrical and electronic equipment for use in environments subject to explosion hazard sold in the EU starting 1 July 2003. From this date onwards, all products sold for use in explosive atmospheres must have ATEX certification and carry the distinctive symbol: The Fluke Ex (IS) product line Fluke is among the first manufacturers to produce handheld test tools according to the latest ATEX standards. The Fluke line of intrinsically safe tools is designed to meet the needs of technicians working in and around hazardous areas: • Install, maintain and troubleshoot equipment by using the new Fluke 87V Ex Digital Multimeter • Maintain and calibrate sensors, transmitters and control loops with the line of Ex field calibrators The tools are ideal for environments in petro-chemical plants, oil platforms, refineries and other locations subject to risk of explosion. Apart from having the ATEX markings, the visual difference between a standard Fluke tool and the corresponding Ex version is the different grey body colour and a red, conductive holster designed specifically to eliminate the potential for electrical discharge. Inside, the Fluke Ex tools have been reengineered to reduce energy avoiding generation of heat and electrical sparks. They are premium products designed for ultimate safety. Making sense of ATEX certification Fluke 707Ex is ATEX-compliant and is certified II 2 G EEx ia IIC T4— but what exactly does that mean? Here a brief explanation of the ATEX certification designations. ATEX certification 707Ex II 2 G EEx ia IIC T4 106 The ATEX examination mark. This sign is required on all devices used in European hazardous areas. The classification of zones. “II” designates the tool is approved for all non-mining areas. “2” represents the category of the device, in this case the device is rated for the second most hazardous areas. “G” designates atmosphere, in this case gas, vapors and mist. Explosion protection based on European Ex-regulations. The type of protection from explosion, in this case the energy in a device or connector has been reduced to a safe value. Gas Group. “IIC” indicates compatibility with the most dangerous gas group. Temperature class gives the user the maximum temperature of a surface that may be in contact to the Ex atmosphere under fault conditions. T4 is rated at 135°C. ATEX-certified Test Tools Fluke intrinsically safe tools for tough measurement and calibration tasks Fluke 87V Ex Intrinsically safe version of the world’s most popular multimeter Fluke 87V Ex With its high performance, accuracy and motor drive compatibility, the Fluke 87V is the most popular industrial multimeter around. Now Fluke has introduced a new intrinsically safe version – the 87V Ex – for measurements in and around hazardous areas. The Fluke 87V Ex has all the measurement and troubleshooting functions of the proven Fluke 87V. Unlike other ATEX-certified tools, it can be used both inside and outside the hazardous zone (ATEX Zones 1 & 2) without compromising performance or compliance. So there’s no need to carry different tools for use in specific zones. It also has a builtin thermometer with TC probe, further reducing technicians’ tool counts. • ATEX safety rating II 2G EEx ia IIC T4 • EN61010-1 CAT III 1000V/CAT IV 600V electrical safety rating Fluke 707Ex Fast, one-handed tool for loop checks The Fluke 707Ex is the ideal, stand alone tool for calibration and maintenance of 4 to 20 mA control loops. It provides 24V loop power while measuring mA, and lets you measure and source/simulate mA with 1 μA resolution. • ATEX safety rating II 2G EEx ia IIC T4 See also page 99 Fluke 707Ex Fluke 718Ex Self-contained Pressure Calibrator The Fluke 718Ex offers a convenient, self contained solution for pressure measurements and calibration. With its internal pressure sensor and pump, it’s ready for immediate, stand alone use. The pressure range can easily be extended to up to 200 bar with any of the 8 Fluke 700PEx Pressure Modules. • ATEX safety rating II IG EEx ia IIC T4 See also page 17 See also page 98 Fluke 725Ex Intrinsically safe Multifunction Process Calibrator The Fluke 725Ex intrinsically safe Multifunction Process Calibrator is powerful yet easy-to-use. Combined with the Fluke 700PEx Pressure Modules, the 725Ex is able to calibrate almost any process instrument likely to need service in any area where explosive gases may be present. • ATEX safety rating II IG EEx ia IIB 171°C Fluke 718Ex Fluke 700Ex Pressure Modules See also page 94 Fluke 725Ex Fluke 700Ex These intrinsically safe pressure modules for use with the Fluke 725Ex Multifunctional Process Calibrator and Fluke 718Ex Pressure Calibrator cover the most commonly used pressure calibration ranges from 0-25 mbar and 0-200 bar. There’s a choice of 8 gage, differential and absolute modules. • ATEX safety rating II 1G EEx ia IIC T4 See also page 102 107 General Accessories The best test tools deserve accessories designed and manufactured to the same high quality and safety standards. So we also provide a comprehensive range of test leads, probes and clips, current clamps, temperature accessories and dedicated electronic and automotive accessories. And to protect your valuable instrument, choose a rugged Fluke tailor-made holster or case. 108 Electronic Test Leads, Probes & Clips Test Leads Test Leads / Patch Cords TL910 Electronic Test Lead Set TL960 Micro-Hook Test Lead Set TP920 Test Probe Adapter Kit • Very small 1 mm tips to access hard to reach test points • Probe tip length up to 100 mm, test lead length: 1m • Included: 3 sets of spring loaded gold tips and 2 sets of stainless steel tips • CAT IV 600 V, CAT III 1000 V, 3 A rating • 1 pair (red, black) of test leads with multi-stacking 4 mm banana plugs and micro-hooks • Micro-hooks attach to component leads up to 1 mm diameter • 90 cm long PVC insulated leads • 30 V rms or 60 V DC, 15 A • Set of push-on adapters for TL71 and TL75 test probes • IC test adapters, extended probe tips, medium alligator clips (max.opening 7.6 mm) • CAT II 300 V, 5 A rating TL930 Patch Cord Set (60 cm) TL970 Hook and Pincer Kit • 1 pair (red, black) multi-stacking 4 mm banana plug patch cords • Nickel-plated banana plugs • 61 cm long PVC insulated leads • 30 V rms or 60 V DC, 15 A • TL940 Mini-Hook Test Lead Set • TL950 Mini-Pincer Test Lead Set • TL960 Micro-Hook Test Lead Set TP912 Replacement Tips for TL910 • Replacement tips for TL910 • Five sets of gold plated and stainless steel tips TL40 Retractable Tip Test Lead Set • One pair (red, black) of test leads with sharp needle point tips adjustable to desired length from 0 to 76 mm • Extra hard probe tips to provide long service life • Flexible silicone insulated test leads • CAT II 150 V, 3 A rating, UL listed TL932 Patch Cord Set (90 cm) • 1 pair (red, black) multi-stacking 4 mm banana plug patch cords • Nickel-plated banana plugs • 90 cm long PVC insulated leads • 30 V rms or 60 V DC, 15 A TL935 Patch Cord Kit (60, 90, 120 cm) TL940 Mini-Hook Test Lead Set • 1 pair (red, black) of test leads with multistacking 4 mm banana plugs and mini-hooks • Mini-hooks attach to component leads up to 1.5 mm diameter • 90 cm long PVC insulated leads • 30 V rms or 60 V DC, 15 A TL950 Mini-Pincer Test Lead Set • 1 pair (red, black) of test leads with multi-stacking 4 mm banana plugs and mini-pincers • Mini-pincers open to 2.3 mm • 90 cm long PVC insulated leads • 30 V rms or 60 V DC, 15 A • 3 sets (red and black pairs) of multi-stacking 4 mm banana plug patch cords • Nickel-plated banana plugs • 60 cm, 90 cm, 120 cm long PVC insulated leads • 30 V rms or 60 V DC, 15 A Kits TL80A Basic Electronic Test Lead Kit • One pair (red, black) each 1 meter long silicone test lead set, alligator clip and probe tip extender. • C75 soft carrying case • CAT II 300 V. UL listed TL81A Deluxe Electronic Test Lead Kit • Includes components of TL80, plus one pair (red, black) each modular 1 meter long silicone test lead, test probe, hook-style and pinch style clip, alligator clip, IC probe tip adapter and spade lugs • Quadfold soft carrying case • CAT II 300 V. UL listed TLK287 Electronic Master Test Lead Kit • Includes modular leads, probes (black and red), minigrabber/jack set, medium alligator clips (black and red), spade lug/banana jack plated (set), couplers IEC1010 (black and red), micrograbbers and -leads (black and red) • TL910 Electronic Test Lead Set • Quadfold Pouch • CAT III 1000 V (probes only) BP980 Double Banana Plug Kit • 5 pair (red, black) of double 4 mm banana plugs • Each plug has 3.1 mm holes for mounting wires and components • Brass plugs/jack, beryllium copper springs • 30 V rms or 60 V DC, 15 A 109 Industrial Test Leads, Probes & Clips Test Leads Modular Test Leads Kits TL71 Premium Test Lead Set TL221 SureGrip™ Extension Lead Set TL220 SureGrip™ Industrial Test Lead Kit • One pair (red, black) of silicone insulated leads with straight connectors on both ends • Reinforced strain relief • Includes one pair (red, black) of female couplers • Extends test leads by 1.5 m • 600 V CAT IV, 1000 V CAT III, 10 A rating. UL listed • AC220 SureGrip™ Alligator Clip Set • TP220 SureGrip™ Test Probe Set • TL222 SureGrip™ Silicone Test Lead Set (right to right) TL222 SureGrip™ Silicone Test Lead Set TL223 SureGrip™ Electrical Test Lead Kit • DMM test leads (red, black) with safety shrouded, standard diameter banana plugs • Right angle connector on both ends • Reinforced strain relief • 1.5 meter silicone-insulated wire resists heat & cold • CAT IV 600 V, CAT III 1000 V, 10 A rating. UL listed • AC220 SureGrip™ Alligator Clip Set • TP1 Slim-Reach™ Test Probes (flat bladed) • TL224 SureGrip™ Silicone Test Lead Set (straight to right) • One pair (red, black) comfort grip probes with silicone insulated, right-angle test leads • Recommended for μV measurements • CAT IV 600 V, CAT III 1000 V, 10 A rating. UL listed TL75 Hard Point™ Test Lead Set • One pair (red, black) comfort grip probes with PVC insulated, test leads with right-angle shrouded banana plugs • Recommended for general purpose measurements • CAT IV 600 V, CAT III 1000 V, 10 A rating. UL listed TL76 All-in-one Test Lead Set • One pair (red, black) 1.5 meter long silicone test leads with right angle shrouded banana plug • Lantern tip (removable) for use with European wall sockets (4 mm Ø ) • Lantern tip can be removed for easy access to terminal blocks (2 mm Ø) • Removable, insulated IC caps allow probing on closely spaced leads and compliance with GS38. • Cat IV 600 V, CAT III 1000 V, 10 A rating, UL listed TL224 SureGrip™ Silicone Test Lead Set • DMM test leads (red, black) with safety shrouded, standard diameter banana plugs • Right angle connector on one end and straight connector on the other • Reinforced strain relief • 1.5 meter silicone-insulated wire resists heat & cold • CAT IV 600 V, CAT III 1000 V, 10 A rating. UL listed TL27 Heavy Duty Test Lead Set • DMM test leads (red, black) with safety shrouded, standard diameter banana plugs • Heavy duty EPDM insulation • Length 1.5 m • CAT III 1000V, 10A rating. UL listed H900 Test Lead Holder SureGrip™ accessories are designed to improve steadiness in slippery hands. Rubber overmolded surfaces and fingerhugging curves give the user a comfortable, reliable grip on the accessory so they can focus on making an accurate measurement. 110 • Heavy duty construction with mounting holes • Holder has 10 slots for wires up to 8 mm in diameter • Over-all dimensions: 27.9 cm L x 8.9 cm W x 3.2 cm H TL238 SureGrip™ High Energy Test Lead Kit • TP238 SureGrip™ Insulated Tip Test Probes with less than 4 mm of exposed metal (GS38) with flexible removable finger banner • TP280 20 cm Test Probe Extenders • TL224 SureGrip™ Silicone Test Lead Set TLK-220 EUR SureGrip™ Accessory Kit • AC220 SureGrip™ Alligator Clip Set • AC285 SureGrip™ Large Jaw Alligator Clip Set • TP74 Slim Reach Test Probe Set (4 mm) • TL224 SureGrip™ Silicone Test Lead Set • Large zippered soft case with moveable divider Industrial Test Leads, Probes & Clips Kits TLK-225 SureGrip™ Master Accessory Kit • AC220 SureGrip™ Alligator Clip Set • AC280 SureGrip™ Hook Clip Set • AC283 SureGrip™ Pincer Clip Set • AC285 SureGrip™ Large Jaw Alligator Clip Set • TP220 SureGrip™ Test Probe Set • TL224 SureGrip™ Silicone Test Lead Set • 6-Pocket Storage Pouch TLK289 EUR Industrial Master Test Lead Kit • C116, Soft Case • AC220 Alligator Clip Set • AC280 Hook Clip Set • AC285 Large Jaw Alligator Clip Set • TP74 Lantern Tip Test Probe Set • TL224 Test Lead Set • TPAK Hanging Kit • 80BK-A Temperature Thermocouple ACC-T5-KIT Accessory Kit for use with T5 This kit completes the offering of a T5 with add-on probes and carrying case. • TP220 SureGrip™ Test Probe Set • AC285 SureGrip™ Large Jaw Alligator Clip Set • C33 Soft Meter Case L215 SureGrip™ Kit with Probe Light and Extender • L200 Probe Light • TP280 20 cm Test Probe Extenders • TP220 SureGrip Test Probes • TL224 SureGrip Silicon Test Lead Set • Foldable soft pouch with six pockets and hook-and-loop Modular Test Probes Modular Test Probes (for use with Modular Test Leads) (for use with Modular Test Leads) TP220 SureGrip™ Test Probe Set TP80 Electronic Test Probe Set • One pair (red, black) of Industrial test probes • Sharp, 12 mm stainless steel tip provides reliable contact • Flexible finger barrier improves grip • Recommended for use with TL222 and TL224 test leads • CAT IV 600 V; CAT III 1000 V, 10 A rating. UL listed Recommended for use with TL222 and TL224 • One pair (red, black) • IC insulated cap prevents shortening of IC legs for probing high density components or boards • CAT III 1000 V, 10 A rating. UL listed TLK291 Fused Test Probe Set • One pair (red, black) fused test probes • Designed to meet GS38 specs for United Kingdom • CAT III 1000V, 0.5A • Fuse rating: 500 mA/1000 V/FF/50 kA TP74 Lantern Tip Test Probe Set • One pair (red, black) • Tips include banana-style spring contacts with nickel-plated brass ends • CAT III 1000 V, 10 A rating. UL listed New TLK290 Test Probe Kit • Kit includes three flexible socket probes and a large alligator clip • To be used on three phase sockets. • Probes have flexible width test points that fit securely in 4 to 8 mm sockets. • CAT III 1000 V, 8 A FTP SureGrip™ Fused Test Probes • Built-in fuses for added protection • 2 mm threaded probe tips include removable 4 mm lantern-style spring contacts • Removable GS38 insulted IC caps for probing closely spaced leads • CAT III 1000 V, CAT IV 600 V, 10A New TP1, TP2, TP4, TP38 SlimReach Test Probe Sets • One pair (red, black) of slender probes for closely spaced or recessed terminals • TP1: Flat blade design to hold securely in blade type wall sockets • TP2: 2 mm diameter tip for electronics work. Also compatible with AC72. • TP4: 4 mm diameter tip designed to fit into IEC wall outlets • TP38: Insulated probe tip (designed to meet GS38 specs for United Kingdom). • CAT IV 600 V, CAT III 1000 V, 10 A rating, UL listed FTPL SureGrip™ Fused Test Probes with Leads • FTP Fused Test Probes with built-in fuses for added protection • Includes TL224 Silicone Insulated Test Leads • CAT III 600 V, CAT IV 600 V, 10 A All accessories have a one year warranty 111 Industrial Test Leads, Probes & Clips Modular Clips Modular Clips Push-on Clip (for use with Modular Test Leads) (for use with Modular Test Leads) (for use with TL71 and TL75 Test Lead Sets) AC220 SureGrip™ Alligator Clip Set AC285 SureGrip™ Large Jaw Alligator Clip Set AC72 Alligator Clip Set • One pair (red, black) of small, insulated, nickel plated jaws • Blunt tip grabs round screw heads up to 9.5 mm • Recommended for use with TL222 and TL224 test leads • CAT IV 600 V, CAT III 1000 V, 10 A rating. UL listed AC280 SureGrip™ Hook Clip Set • One pair (red, black) of nickel plated clips • Profile narrows to 5.6 mm at tip, hook opening 6.4 mm at front, 2 mm at base • Recommended for use with TL222 and TL224 test leads • CAT IV 600 V, CAT III 1000 V, 3 A rating. UL listed AC283 SureGrip™ Pincer Clip Set • One pair (red, black) of nickel plated pincers open to 5 mm • 11.4 cm flexible insulated shaft • Recommended for use with TL222 and TL224 test leads • CAT IV 600 V, CAT III 1000 V, 1 A rating. UL listed • One pair (red, black) of large alligator clips with nickel-plated steel jaws • Multi-purpose tooth pattern grips anything from fine gauge wire to a 20 mm bolt • Recommended for use with TL222 and TL224 test leads • CAT IV 600 V; CAT III 1000 V, 10 A rating. UL listed AC87 Heavy Duty Bus Bar Clip Set • One pair (red, black) of flat, right angle design for connecting to bus bars • Adjustable collar provides 2 ranges of jaw openings up to 30 mm • CAT III 600 V, 5 A rating. UL listed AC89 Heavy Duty Insulation Piercing Test Clip • Single probe pierces 0.25 to 1.5 mm insulated wire • Small pin allows self-healing of the insulation • CAT IV 600V, CAT III 1000 V, 5 A rating. UL listed • Slide-on alligator clips (red, black) for TL71/TL75 • Jaws provide 8 mm opening • CAT IV 600 V, CAT III 1000 V, • 10 A rating. UL listed Test Leads and Probes in one The new standard for safer electrical measurements TL175 and TP175 TwistGuard™ test leads are the latest in the SureGrip™ technology from Fluke that provides two safety features in one set of test leads. These new patented test leads provide two category rated tips (CAT III/IV) with a simple twist of the shroud. The lead wires on the TL175 are equipped with wear indication, that show when the leads have excessive wear and that it is time to replace them. The TL175 and TP175 meet the new NFPA 70E (IEC 61010-031) safety standard which is the standard for electrical safety in the workplace. New TL175 TwistGuard™ Test Leads • Probes meet new IEC 61010 requirements for safety • Patented extendable tip sheath meets new CAT III 1000 V, CAT IV 600 V requirements while providing the flexibility you need for CAT II measurements • Double insulated silicone leads with Wear indication for increased safety • Probes always show correct Category rating for tip being used • Advanced strain relief exceeds 5,000 bend life • One-year warranty 112 SureGrip™ accessories are designed to improve steadiness in slippery hands. Rubber overmolded surfaces and fingerhugging curves give the user a comfortable, reliable grip on the accessory so they can focus on making an accurate measurement. All accessories have a one year warranty Automotive Accessories Piercing Clips Pressure Module TP81 and TP82 Insulation Piercing Clip Set PV350 Pressure Vacuum Module • Banana jack accepts all DMM and banana jack leads • Available for 4 mm input, modular connection with TP81 or available as a 2 mm input to slip onto probe tips with the TP82 • Tested to 60 V DC TP84 Oxygen Sensor Insulation Piercing Clip • Banana jack accepts all DMM and banana jack leads (4 mm) • Tested to 60 V DC • Compatible with all Fluke and most popular DMMs • Digital pressure and vacuum measurements in a single module • Transducer sealed in 316 stainless steel compatible with variety of liquids and gases • Measures vacuum to 76 cm Hg • Display results in English (psig or Hg) or metric (kPa or cm Hg) units • Measures pressure to 500 psig (3447 kPa) 90i-610s AC/DC Current Probe (600 A) Test Leads • Flexible silicone insulated leads are heat and cold resistant • CAT I 30 V, 10 A TP88 Rigid Back Probe Pin Set • Slides onto test probes measuring 2 mm • Tested to 60 V DC TP40 Automotive Back Probe Pins (five) • Banana jack accepts all DMM and banana jack leads (4 mm) • Tested to 60 V DC TLK281 SureGrip™ Automotive Test Lead Kit Kit contains: • TP81 Insulation Piercing Clip Set • TL224 SuregripTM Silicone Test Lead Set • TP220 SuregripTM Test Probe Set • AC220 SuregripTM Alligator Clip Set • AC285 SuregripTM Large Jaw Alligator Clip Set • Soft Case BP880 • Allows for hands-free testing in controlled voltage environments 500 VRMS maximum • Banana plug is nickelBP881 plated, beryllium copper for low contact resistance • The BNC shell is plated for tarnish resistance • Operating temperature +50°C maximum • Current Range: 2 to 600A DC or AC Peak • Basic Accuracy (DC to 400Hz): ± (2% of reading + 1A) • Output Signal: 100A range: 10mV/A 600A range: 1mV/A • Frequency Range: 40Hz to 400Hz • Working Voltage: 600V AC rms • Maximum Conductor Diameter: 34 mm Inductive Pick-up RPM80 Inductive Pick-up • Provides RPM readings ScopeMeter Accessory Kits SCC128 Automotive Accessory Kit (120 Series) Banana Plugs BP880 BNC to Female Double Stacking Banana Plug BP881 BNC to Male Double Stacking Banana Plug This set of male and female adapters allows you to make firm connection to pin and socket connectors. Kit contains: • Retractable shrouded test lead set • Complete set of 8 pin-and-socket adapters with flexible tips • One red and black in different sizes • Rated to 60 V DC Current Probe TL28A Automotive Test Lead Set Probe Pins TL 82 Automotive Pin & Socket Adapter Kit TLK282 SureGrip™ Deluxe Automotive Test Lead Kit Kit contains: • TP81 Insulation Piercing Clip Set • TP40 Automotive Back Probe Pins (five) • TL224 SuregripTM Silicone Test Lead Set • TP220 SuregripTM Test Probe Set • AC220 SuregripTM Alligator Clip Set • AC285 SuregripTM Large Jaw Alligator Clip Set • AC280 SuregripTM Hook Clip Set • Soft Case SCC198 Automotive Accessory Kit (190 Series) These kits provide a host of accessories that allow you to easily and quickly make measurements on automotive electronic systems using a 120 or 190 Series ScopeMeter. 113 Current Clamps i5s i50s i200 i200s i400 i400s Specifications AC models i5s i50s i200 i200s i400 i400s Nominal current range(s 5A 3/30 AC RMS or DC 200 A 20 A 200 A 400 A 40 A 400 A Continuous AC current range 0.01 A - 6 A 30 A cont. 50 A<10 sec 0.5 A - 200 A 0.1 - 24 A 0.5 A - 200 A 5 A - 400 A 0.5 - 40 A 5 A - 400 A Highest current Lowest measurable current Basic accuracy (48-65 Hz) 1) 70 A 10 mA 1% 240 A 0.5 A 1% + 0.5 A 240 A 0.5 A 1.5% + 0.5 A 1000 A 1A 2% + 0.15 1000 A 0.5 A 2% + 0.15 Useable frequency Max. working voltage Maximum conductor diameter 40 Hz - 5kHz 600 V AC 15 mm 30 A cont. 50 A<10 sec 10 mA ± 5% typical DC to 100 kHz DC to 50 MHz 300 V AC RMS or DC 5 mm 40 Hz - 10 kHz 600 V AC 20 mm 40 Hz - 10 kHz 600 V AC 20 mm 45 Hz - 3 kHz 1000 V 32 mm 45 Hz - 3 kHz 1000 V 32 mm Output level(s) 400 mV/A 1/100 mV/A 1 mA/A 100 mV/A 10 mV/A 1 mA /A 10 mV/A 1 mV/A 2.5 External Power 2 1.5 O 2.0 1.5 O 2.5 • O CAT III, 600 V CAT I 300 V Batttery, battery life Output cable (m) Shrouded banana plugs BNC connector BNC to banana adapter included Safety 1) i1000s i2000 flex i3000s flex i800 i10000s i2000 flex Nominal current range(s) 800 A RMS Continuous AC current range 0.1 A - 800 A RMS Highest current Lowest measurable current Basic accuracy (48-65 Hz) 1) Useable frequency Max. working voltage Maximum conductor diameter 1500 A 0.1 A 0.10% 30 Hz - 10 kHz 600 V AC RMS or DC 54 mm 10 A 100 A 1000 A 0.1 A - 10 A 0.1 A - 100 A 1 A - 1000 A 2000 A 0.1 A 1% + 1 A 5 Hz - 100 kHz 600 V AC 54 mm 20 A 200 A 2000 A 1 A - 20 A 2 A - 200 A AC RMS 30 A - 2000 A 2500 A AC RMS 1A 1% 10 Hz - 20 kHz (-3dB) 600 V AC RMS 178 mm Output level(s) 1 mA/A 100 mV/A 10 mV/A 1 mV/A 100 mV/A 10 mV/A 1 mV/A 200 hours 0.5 O n/a n/a CAT III, 600 V Batttery, battery life Output cable (m) Shrouded banana plugs BNC connector BNC to banana adapter included Safety 114 O O CAT III, 600 V O CAT III 1000 V / CAT IV 600 V CAT III 1000 V / CAT IV 600 V Basic Accuracy: % reading + floorspec i800 1) CAT III. 600 V Basic Accuracy: % reading + floorspec 1.6 O 1.6 O CAT III, 600 V CAT III, 600 V i3000s flex-24 i3000s flex-36 30 A 300 A 3000 A 1 A - 30 A 2 A - 300 A AC RMS 30 A - 3000 A 3500 A AC RMS 1A 1% 10 Hz - 50 kHz (-3dB) 600 V AC RMS Flex-24 178 mm Flex-36 275 mm 100 mV/A 10 mV/A 1 mV/A 400 hours 0.5 n/a O O CAT III, 600 V i3000s i6000s flex i3000s i60000 flex-24 i6000s flex-36 60 A 600 A 6000 A AC 1 A - 6000 A AC RMS 30 A 300 A 3000 A 1 A - 30 A 1 A - 300 A 1 A - 2400 A 4000 A 1A 2% + 2 A 10 Hz - 100 kHz 600 V AC 64 mm 2.1 6000 A 1A ± 1% of range 10 Hz to 50 kHz 600 V AC RMS or DC Flex-24 170 mm Flex-36 275 mm 50 mV/A 5 mV/A 0.5 mV/A 400 hours 0.5 O O CAT III, 600 V O O CAT III, 600 V 10 mV/A 1 mV/A 0.1 mV/A Current Clamps 80i-110s i30 i30s i310s i410 i1010 Specifications AC/DC Models Highest current 80i-110s Hall sensor 10 A, AC/DC 100 A, AC/DC 0.1 A - 10 A AC/DC 1 A - 100 A AC/DC 140 A - 2 kHz Lowest measurable current Basic accuracy 1) Useable frequency Zero error adjustment 0.1 A 3% + 50 mA (@ 10 A) DC - 100 kHz O Max. working voltage Maximum conductor diameter 600 V 11.8 mm Output level(s) 100 mV/A 10 mV/A 9 V, 55 h 1.6 Measurement type Nominal current range(s), Continuous current range Battery, battery life Output cable length (m) Shrouded banana Plugs BNC connector BNC to banana adapter included Safety 1) O CAT II, 600 V CAT III, 300 V i30 Hall sensor 20 A AC RMS or DC i30s Hall sensor 20 A AC RMS or DC i310s AC/DC 30/300 A AC RMS or 45/450 A DC 100 mA - 300 A AC RMS or 450 A DC 300 A AC RMS or 450 A DC 100 mA ±1% of reading DC to 20 kHz Manual 30 A AC Peak 30 A AC Peak 30 A AC Peak 30 A AC Peak 50 mA ± 1% of reading ±2 mA DC to 20 kHz (-0.5dB) manual adjust via thumbwheel 300 V AC RMS 19 mm 50 mA ± 1% of reading ±2 mA DC to 100 kHz (-0.5dB) manual adjust via thumbwheel 300 V AC RMS 19 mm 100 mV/A 100 mV/A 10/1 mV/A 30 hours typical 1.5 O n/a n/a CAT III, 300 V 30 hours typical 2 n/a O O CAT III, 300 V 30 hours 2 i410 Hall sensor 400 A, AC/DC 400 A i1010 Hall sensor 600 A, AC 1000 A, DC 1 A - 600 A, AC 1 A - 1000 A, DC 1000 A 0.5 A 3.5% + 0.5 A DC - 3 kHz O 0.5 A 2% +0.5 A DC - 10 kHz O 600 V 30 mm 2 x 25 mm 1 mV/A 600 V 30 mm 2 x 25 mm 1 mV/A 9 V, 60 h 1.6 O 9 V, 60 h 1.6 O CAT III, 600 V CAT III, 600 V 1 A - 400 A AC/DC 300 V AC RMS or DC 19 mm O O CAT III 300 V Basic Accuracy: % reading + floorspec O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O O O 2 O O O 2 2 2 2 2 2 2 2 2 2 2 O O O O O 2 O O O O O O O O O O O O 3 O O O 3 O O O 3 O O O O O 3 3 O O O 3 3 O O O 3 3 O O O O O O O 2 O 3 O O 3 O O O 789 4 2 O O O O O 787 O O O 2 741B/743B/744 O O O 2 725 O O O 2 724 88V O O O 2 715 83V/87V O O O 2 1577/1587 77 IV O O O 2 190 Series/215C/225C 8808A O O O 2 4 O 125 8845A/8846 O O O 2 123/124 27II / 28II O O O 2 430 Series 287/289 2 O O O 2 43B 233 • Combination of current clamp with carrying case • Zipped soft case with moveable divider • Soft case is large enough to hold a meter 187/189 i410 Kit AC/DC Current Clamp (400A) with soft case i1010 Kit AC/DC Current Clamp (1000A) with soft case AC Models i5s i200 i200s i400 i400s i430 flex i800 i1000s i2000 flex (new version) i3000s i3000s flex i6000s flex AC/DC Models i30 i30s 80i-110s i310s i410 / i410 kit i1010 / i1010 kit Other 90i-610s* 175/177/179 113/114/115/116/117 Current Clamp Compatibility Chart O O O 2 O O O 2 O 2 O O O O O 2 O O O O O O 2 O O O 2 O O O 2 O O O 2 2 2 O 2 O 2 O O O O 2 O O O O O O O O O O 1 1 1 1 1 1 * For specifications of 90i-610s see page 113 1 For DC only 2 Requires PM 9081 (see page 76) 3 Requires PM 9082 (see page 76) 4 115, 117 only All accessories have a one year warranty 115 Temperature Accessories DMM Probes Contact Probes 80PK-22 SureGrip™ Immersion Probe 80PK-1 and 80PJ-1 Bead Probe 80AK-A Thermocouple Adapter • Type-K thermocouple for use in liquids and gels • Measurement range: -40 to 1090°C • Probe length: 21.3 cm • 80PK-1: Type-K thermocouple for general purpose applications • 80PJ-1 operates with J-type thermometers • Measurement range: -40 to 260°C • Probe length: 1 m lead wire • Adapts Type-K thermocouple mini-connector to dual banana plug inputs • Measurement range and accuracy: probe dependent • Suitable for low voltage applications (below 30 V AC, 60 V DC) 80BK-A Integrated DMM Probe 80PK-24 SureGrip™ Air Probe • Type-K thermocouple for use in air and non-caustic gas measurements • Bead protected by perforated baffle • Measurement range: -40 to 816ºC • Probe length: 21.6 cm 80PK-3A Surface Probe • Type-K thermocouple for flat or curved surfaces such as plates and rollers • Measurement range: 0 to 260°C • Probe length: 9.5 cm 80PK-25 and 80PT-25 SureGrip™ Piercing Probe • 80PK-25: Type-K thermocouple suitable for food industry, liquids and gels • 80PT-25 operates with T-type thermometers • Measurement range: 80PK-25: -40 to 350°C 80PT-25: -196 to 350°C • Probe length: 10.2 cm 116 80PK-8 / 80PK-10 Pipe Clamp Temperature Probe New • Type-K thermocouple for fast temperature and superheat measurements of pipe surfaces • Durable ribbon sensor • Measurement range: -29 to 149°C for pipe diameters from 6.4 to 34.9mm (80PK-8) and 32 mm to 64 mm (80PK-10) 80PK-26 SureGrip™ General Purpose Probe 80PK-9 and 80PJ-9 General Purpose Probe • Type-K thermocouple with tapered tip for use in air, non-caustic gas and surface applications • Measurement range: -40 to 816ºC • Probe length: 21.2 cm • 80PK-9: Type-K thermocouple surface, air and non-caustic gases • 80PJ-9 operates with J-type thermometers • Measurement range: -40°C to 260°C • Probe length: 15.3 cm 80PK-27 SureGrip™ Industrial Surface Probe 80PK-11 Velcro Temperature Probe • Type-K thermocouple for surfaces in rugged environment • Durable ribbon sensor • Measurement range: -127 to 600°C • Probe length: 20.3 cm • Type-K thermocouple for hands free measurement of HVAC temperature measuring applications • Total length of cable: 1m (0.5m in cable, 0.5m in Velcro cuff insulation material; Hytrel) • Measurement range: -30ºC to 105ºC • Type-K thermocouple with standard banana jack • Convenient one piece construction • Compatible with DMMs with temperature measurement functions • Measurement range: -40 to 260ºC 80TK Thermocouple Module • Converts a DMM to a thermometer • For use with type-K thermocouples in low voltage applications (below 24 V AC, 60 V DC) • Measurement range: -50 to 1000°C (probe dependent) 80T-150UA Universal Temperature Probe • Compatible with Fluke DMM • High accuracy, fast reading for low voltage (below 24 V AC, 60 V DC) applications • Measurement range: -50 to 150°C • Output: 1 mV/°C or 1 mV/°F (switchable) SureGrip™ accessories are designed to improve steadiness in s lippery hands. Rubber overmolded surfaces and fingerhugging curves give the user a comfortable, reliable grip on the accessory so they can focus on making an accurate measurement. Temperature Accessories Other Temperature Accessories 80PR-60 RTD Temperature Probe • For simulaneously taking contact and non-contact temperature measurements with Fluke 66 or 68 • Measurement range: -40 to 260°C New 80CK-M & 80CJ-M type K & J Male Mini-Connectors Thermocouple Plug Kits 700TC1 • Isothermal screw terminal for K or J wire • Suitable for up to 20 guage thermocouple wire • Color coded to industry standards (K-yellow, J-black) • Two per package A kit of 10 mini-plug connectors Type J (black), one Type K (yellow), one Type T (blue), one Type E (purple), one Type R/S (green), one Type B or CU (white), one Type L (J-DIN) (blue), one Type U (T-DIN) (brown), one Type C (red), one Type N (orange), one 80PK-EXT, 80PJ-EXT and 80PT-EXT Extension Wire Kits 700TC2 • Extending and repairing J, K ot T-type thermocouple wires • Kit includes 3 meters of thermocouple wire and 1 pair of male/female mini-connectors • Maximum continuous exposure temperature: 260ºC • 80PK-EXT is compatible with K-type thermometers, 80PJ-EXT is designed for J-type thermometers and PT-EXT for T-type thermometers 80PK-18 Pipe Clamp Temperature Probe Kit • 80PK-8 Pipe Clamp Temperature Probe • 80PK-10 Pipe Clamp Temperature Probe • Soft Case A kit of 7 mini-plug connectors Type J (black), two Type K (yellow), two Type E (purple), one Type T (blue), one Type R/S (green), one 190 Series/225C/215C 1577 1587 1 1 1 1 2 1 O O O O O O O O O O O O O O O O O O O O 1 1 2 2 2 2 1 1 1 2 1 1 2 2 2 2 1 1 1 2 O3) O3) O O O O O O O O O 1 O O O 1 O O O O O O O O O 789 120 Series 2 787 43B 2 741B/743B/744 88V 1 725 87V 1 724 83V 1 715 77IV 2 714 8845A/8846A/8808A 2 705/707 27II / 28II 2 66/68 287/289 2 566/568 233 1 561 179 1 51/52/53/54 II 175/177 Contact Probes 80PK-1 … 80PK-27 80PJ-1, 80PJ-9 80PT-25 DMM probes 80AK-A 80BK-A 80TK 80T-150UA Miscellaneous 80CK-M 80CJ-M 80PK-EXT4) 80PJ-EXT 80PT-EXT 700TC1, 700TC2 80PR-60 113/114/115/116/117 Temperature Probe Compatibility Chart 1 1 O O O O O O O O O O O O 1 1 1 1 O O O O O O O O O O O O 2 1 1 1 1 2 2 1 1 1 1 2 O O O O O O O O 1 O O 1 O O O O O O O O 1 1 O O O O O O O O O O O O O 1) Requires 80TK 2) Requires 80AK 3) Fluke 116 only 4) Also requires 80CK-M All accessories have a one year warranty 117 Cases and Holsters Soft Cases Zipped carrying cases protect your meter; most cases come with belt loops so your meter is stored conveniently on your tool belt. C195 • Zipped carrying case with storage compartments • Allows hand or shoulder use C789 C12A C23 C25 • Large fabric carrying case with 3 compartments, removable handle and shoulder strap C35 C33 C550 Tool Bag C570 C43 C50 C75 C90 C115 C116 C125/C781 C280 C345 • Steel reinforced frame • Rugged ballistic cloth with heavy duty hardware • Large zippered storage compartment with 25 pockets • Weather resistant • Carry all your tools to the job 118 787 789 741B/743B/744 724/725/726 718 712/714/715/717 705/707 63/66/68 61 O 570 Series 51/52/53/54 II O O 566/568 971 O O 561 922 190 Series/225C/215C 43B/120 Series O 430 Series 9040/9062 O 1735/1740 Series 1503/1507/1577/1587 353/355 333/334/335/336/337/902 321/322 T100 Series T50 T5 O O O O O 83V/87V/88V 77 IV O 27II / 28II O 287/289 O O O 233 175/177/179 Soft Cases Size (HxWxD) mm C12A 172 x 128 x 38 C23 225 x 95 x 58 C25 218 x 128 x 64 C33 280 x 115 x 55 C35 220 x 140 x 65 C43 318 x 230 x 90 C50 192 x 90 x 38 C75 179 x 103 x 26 C90 205 x 90 x 72 C115 240 x 205 x 75 C116 240 x 230 x 65 C125 192 x 141 x 58 C195 231 x 513 x 231 C280 230 x 185 x 65 C345 240 x 360 x 200 C550 333 x 513 x 231 C570 240 x 160 x 61 C781 269 x 141 x 90 C789 308 x 256 x 77 Hard cases C20 256 x 154 x 106 C100 397 x 346 x 122 C101 305 x 360 x 105 C120 346 x 397 x 128 C190 410 x 474 x 135 C435 565 x 476 x 305 C800 230 x 385 x 115 C1600 260 x 390 x 200 CXT80 28 x 32 x 13 CXT170 28 x 32 x 13 CXT280 28 x 32 x 13 Leather Cases C510 287 x 179 x 106 C520A 256 x 154 x 106 Holsters C10 154 x 77 x 45 H80M 190 x 95 x 43 Other H3 231 x 90 x 64 H5 192 x 90 x 38 H6 302 x 178 x 57 Hanging Kit (see page 120) ToolPak 113/114/115/116/117 Cases & Holsters Compatibility Chart O O O O O O O O O O O O O O O O O O O For multiple test leads and accessories O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O For multiple test leads and accessories For multiple test leads and accessories O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O For multiple test leads and accessories O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O Cases and Holsters Hard Cases Holsters C20 Meter Case C10 Meter Holster H3 Clamp Meter Holster • Heavy duty case with carrying handle and accessories storage compartment • Top cover snaps onto back to serve as tilt stand • Snap-on yellow holster absorbs shocks and protects meter from rough handling • Includes built-in stand and hanger loop • Fabric holster absorbs shocks and protects meter from rough handling. • Built-in pocket for lead storage • Convenient belt-loop with snap H80M Holster + Magnetic Hanger C100 Meter and Accessory Case • Tough polyprophylene case C101 Hard Case The hard case that fits all Fluke industrial test tools. Configure the diced foam interior to store and protect what you need to carry with you. • Tough polyprophylene exterior shell • Interior cavity measures • Snap-on yellow holster absorbs shocks and protects meter from rough handling • Magnet, hook and loop straps • General purpose hanger H5 Electrical Tester Holster • Rugged fabric holster includes flap for lead storage and built-in belt loop • Fits Fluke T3 and T5 testers H6 Infrared Thermometer Holster • Durable nylon holster • For Fluke 63, 66 and 68 Infrared Thermometers C120 and C190 Cases • Heavy duty cases with accessory storage compartments C435 Hard Rolling Case • Watertight hard case with rollers for 430 Series, 1735 and 1740 Series Power Quality products and accessories. The configurable foam securely holds any of these instruments during transit. C800 Meter and Accessory Case Leather Cases C510 Leather Meter Case C520A Leather Tester Case • Oiled genuine top grain cowhide • Rugged construction with heavy duty stitching and reinforced rivets • Large tool belt loop and top flap to secure meter • Holds most Fluke DMMs, Thermometers, and Process Calibrators • Oiled genuine top grain cowhide • Oil tanned for long life • Rugged construction with heavy duty stitching and reinforced rivets • Large tool belt loop and top flap to secure tester • Holds Fluke Electrical Testers • Tough polyprophylene case • Accessories and manual compartments • Detachable lid C1600 Meter and Accessories Case • Rugged molded plastic case • Deep interior large enough to hold and protect your tools • Lift out tray keeps everything organized • Snap open compartment on top of lid CXT80, CXT170, CXT280 Rugged Pelican Hard Case • Unbreakable, watertight, airtight, dustproof, chemical resistant and corrosion proof case All accessories have a one year warranty 119 Software and other Accessories Software FlukeView® Forms Hanging Kit FlukeView Forms increases the power of your Fluke tool by enabling you to document, store and analyze individual readings or series of measurements, then convert them into professional-looking documents. FlukeView Forms supports the following multimeters: ToolPak (TPAK) The meter hanging solution • Kit includes, universal hanger clips (2), hook & loop straps (2 lengths) and strong magnet • Combine components to meet most hanging needs See page 118 for compatibility chart FlukeView Forms Compatibility Chart FVF Option FVF-UG FVF-SC1 FVF-SC2 FVF-SC4 FVF-BASIC FVF-SC5 Instrument Software only upgrade, Any instrument that supports Flukeview Forms Software Fluke 53-II, 54-II, 87-IV*, 89-IV* Fluke 280 Series, 789, 1550B, 1653B, 568,180 Series* Fluke 8808A, 8845A, 8846A, 45*, 975 Fluke 280 Series, 789, 1550B, 1653B, 180 Series* 8808A, 8845A, 8846A, 45* Cable** Application Level No Cable included Serial / IRDA USB / IR USB / Serial USB / IR USB / Serial FVF Full (includes Designer) FVF BASIC * Obsolete ** USB cables are not supported for Microsoft Windows NT 4.0 IR189USB IR to USB interface cable (included with FVF-SC2 and FVF-Basic) • For customers who want to upgrade from their existing RS232 cable • Small adapter to connect the cable to the 189, 287, 289, 1653B or the 1550B is included. • CD-Rom with drivers for use with older versions of FVF-SC1 included. Fiber Optics FOM Fiber Optic Meter Make extended logging easier BP189 High Capacity Battery Enclosure (for Fluke 180 Series DMM) • Expand the battery life of your Fluke 187/189 up to 450 hours (over two weeks of continuous use). • Houses 4 ‘C’ cell batteries. • CAT III 1000 V, CAT IV 600 V Batteries and meter sold separately 120 The Fluke Fiber Optic Meter (FOM) helps you test and maintain fiber optic cables without having to buy a whole new meter. Plug the FOM directly into any DMM with a mV dc function and a 10 MΩ input impedance and quickly and accurately verify fiber optic cable system loss. Light sources and patch cords sold separately. FOS 850 & FOS 850/1300 Fiber Optic Light Sources A variety of light sources allow you to test different cable lengths. All accessories have a one year warranty Other Accessories Lights Stray Voltage Adapter High Voltage Probes L200 Probe Light SV225 Stray Voltage Adapter 80K-6 and 80K-40 • Attaches to any Fluke test probe • Bright white LED • 120 hours of battery life Stray voltage can appear in electrical installations, due to the capacity between wires. This may result in erroneous readings on high impedance meters. A high voltage probe that allows a multimeter to measure up to 6,000V or 40,000V respectively. Intended for low energy applications only L205 Mini Hat Light Rugged high-intensity Xenon worklight • Attaches to a baseball cap • Includes a hat clip • Includes two AAA batteries • Waterproof L206 Deluxe LED Hat Light (hard hat not included) Attach it to a hard hat, a baseball cap, or even a panel door for all the light you need. • 3 super bright white LEDs – never burn out • Special hard-hat attachment included • 40-hour battery life • Includes three AAA batteries The SV225 solves this without compromising safety. • On energized wires, the meter will indicate the real voltage. • On non-energized circuits the meter will read close to zero (even if there are stray voltages). • It can be used with all modern meters with standard input spacing. • Rated CAT III 1000 V, CAT IV 600 V TL225 SureGrip™ Stray Voltage Adapter Test Lead Kit Kit includes: • SV225 Stray Voltage Eliminator • TL224 SureGrip™ Silicone Test Lead Set (right to straight) • TP220 SureGrip™ Test Probe Set • C75 Accessory Case L210 Probe Light + Probe Extender • Includes L200 Probe Light and TP280 Test Probe Extenders • 20 cm probe extenders keep hands away from live circuits • Extender fits between modular test probe and test lead (total reach 30 cm) Meter Cleaners MC6 MeterCleaner™ Wipes (6-pack) MC50 MeterCleaner™ Wipes (50-pack) • Pre-moistened wipe removes dirt, oil and grease • One wipe easily cleans one meter • Safe on rubber, plastic and for environment (non-toxic) All accessories have a one year warranty 121 Product Quick Find List Model 122 Page Fluke 1AC I 32 Fluke 1AC II 32 Fluke 1AC II 5PK 32 Fluke 27II 21 Fluke 28II 21 Fluke 43B 81 Fluke 51 II 55 Fluke 52 II 55 Fluke 53 II 55 Fluke 54 II 55 Fluke 61 52 Fluke 62/322/1AC Kit 5, 52 Fluke 62 52 Fluke 63 52 Fluke 66 52 Fluke 68 52 Fluke 771V 20 Fluke 83V 17 Fluke 87V 17 Fluke 87V Ex 107 Fluke 87V/E2 Kit 4 Fluke 87V/i410 4 Fluke 88V/A 22 Fluke 113 19 Fluke 114 19 Fluke 115 19 Fluke 116 19 Fluke 117 19 Fluke 117/322 Kit 4 Fluke 123 73 Fluke 123/S 73 Fluke 124 73 Fluke 124/S 73 Fluke 125 73 Fluke 125/S 73 Fluke 175 18 Fluke 177 18 Fluke 179 18 Fluke 179/TPAK kit 4 Fluke 179/EDA2 Kit 4 Fluke 179/MAG2 Kit 4 Fluke 179/61 Kit 4 Fluke 192C 75 Fluke 192C/S 75 Fluke 196C 75 Fluke 196C/S 75 Fluke 199C 75 Fluke 199C/S 75 Fluke 215C 75 Fluke 215C/S 75 Fluke 225C 75 Fluke 225C/S 75 Fluke 233 16 Fluke 287 15 Fluke 289 15 Fluke 287/FVF 5 Fluke 289/FVF 5 Fluke 321 27 Fluke 322 27 Fluke 333 26 Fluke 334 26 Fluke 335 26 Fluke 336 26 Fluke 337 26 Fluke 345 80 Fluke 353 28 Fluke 355 28 Fluke 360 29 Fluke 411D/62 Kit 5, 65 Fluke 411D 65 Fluke 416D 65 Fluke 421D 65 Fluke 434 83 Fluke 434 Basic 83 Fluke 434 LOG 83 Fluke 435 83 Fluke 435 Basic 83 Fluke 561 54 Fluke 566 53 Fluke 568 53 Fluke 572 51 Fluke 572CF 51 Fluke 574 51 Fluke 574CF 51 Fluke 700 Ex 107 Fluke 705 99 Fluke 707 99 Model Page Fluke 707 Ex 99,107 Fluke 712 96 Fluke 714 96 Fluke 715 99 Fluke 717 1G 98 Fluke 717 100G 98 Fluke 717 1000G 98 Fluke 717 1500G 98 Fluke 717 30G 98 Fluke 717 300G 98 Fluke 717 500G 98 Fluke 717 3000G 98 Fluke 717 5000G 98 Fluke 718 Ex 98,107 Fluke 718 1G 98 Fluke 718 30G 98 Fluke 718 100G 98 Fluke 718 300G 98 Fluke 719 30G 98 Fluke 719 100G 98 Fluke 724 95 Fluke 725 94 Fluke 725 Ex 94,107 Fluke 726 94 Fluke 741B 93 Fluke 743B 93 Fluke 744 93 Fluke 771 100 Fluke 772 100 Fluke 773 100 Fluke 787 101 Fluke 789 101 Fluke 810 104 Fluke 902 26 Fluke 922 68 Fluke 922/Kit 68 Fluke 971 69 Fluke 975 67 Fluke 975V 65 Fluke 983 70 Fluke 1503 38 Fluke 1507 38 Fluke 1523 56 Fluke 1523-P1 56 Fluke 1524 56 Fluke 1524-P1 56 Fluke 1550B 39 Fluke 1577 37 Fluke 1587 37 Fluke 1587/ET 5, 36 Fluke 1587/MDT 5, 36 Fluke 1587T 37 Fluke 1621 41 Fluke 1623 40 Fluke 1623 Kit 40 Fluke 1625 40 Fluke 1625 Kit 40 Fluke 1630 42 Fluke 1651B 44 Fluke 1652B 44 Fluke 1653B 44 Fluke 1735 84 Fluke 1743 85 Fluke 1743 Basic 85 Fluke 1744 85 Fluke 1744 Basic 85 Fluke 1745 85 Fluke 1750 86 Fluke 1750/B 86 Fluke 1760 87 Fluke 1760 Basic 87 Fluke 1760TR 87 Fluke 1760TR Basic 87 Fluke 2042 34 Fluke 2042T 34 Fluke 4180 97 Fluke 4181 97 Fluke 4180-CASE 97 Fluke 4180-DCAS 97 Fluke 6200 46 Fluke 6500 46 Fluke 8808A 24 Fluke 8808A/SU 24 Fluke 8808A/TL 24 Fluke 8845A 23 Fluke 8845A/SU 23 Fluke 8846A 23 Model Page Fluke 8846A/SU 23 Fluke 9040 33 Fluke 9062 33 Fluke 9142-X 97 Fluke 9143-X 97 Fluke 9144-X 97 Fluke CO-205 69 Fluke CO-220 69 Fluke Norma 4000 89 Fluke Norma 5000 89 Fluke RLD2 70 Fluke T5-600 31 Fluke T5-600/62/1AC Kit 5, 31 Fluke T5-H5-1AC Kit 5, 31 Fluke T5-1000 31 Fluke T50 30 Fluke T100 30 Fluke T120 30 Fluke T140 30 Fluke Ti9 60 Fluke Ti10 60 Fluke Ti25 61 Fluke Ti32 61 Fluke TiRx 62 Fluke TiR 62 Fluke TiR1 63 Fluke TiR32 63 Fluke VR1710 79 80AK-A 116 80BK-A 116 80CJ-M 117 80CK-M 117 80i-110s 115 80K-40 121 80K-6 121 80PJ-1 116 80PJ-9 116 80PJ-EXT 117 80PK-1 116 80PK-3A 116 80PK-8 116 80PK-9 116 80PK-10 116 80PK-11 116 80PK-18 117 80PK-22 116 80PK-24 116 80PK-25 116 80PK-26 116 80PK-27 116 80PK-EXT 117 80PR-60 117 80PT-EXT 117 80T-150UA 116 80TK 116 90i -610s 113 700HTH 102 700HTP 102 700ILF 102 700LTP 102 700P00 102 700P01 102 700P01 Ex 102,107 700P02 102 700P03 102 700P04 102 700P05 102 700P05 Ex 102,107 700P06 102 700P06 Ex 102 700P07 102 700P08 102 700P09 102 700P09 Ex 102,107 700P22 102 700P23 102 700P24 102 700P24 Ex 102,107 700P27 102 700P27 Ex 102,107 700P29 102 700P29 Ex 102,107 700P30 102 700P31 102 700PA3 102 700PA4 102 Model Page 700PA4 Ex 102,107 700PA5 102 700PA6 102 700PCK 102 700PD2 102 700PD3 102 700PD4 102 700PD5 102 700PD6 102 700PD7 102 700PRV 102 700PTP 102 700PV3 102 700PV4 102 700SW 93 700TC1 117 700TC2 117 884X-case 18 884X-512M 18 975CK 67 975R 67 975VP 67 2373-LPRT 56 2384P 56 2384T 56 5616-12-P 56 5615-9-P 56 5610-9-P 56 AC72 112 AC87 112 AC89 112 AC220 112 AC280 112 AC283 112 AC285 112 ACC-T5-Kit 111 AN5 51 APP1000/APP2000 48 AS200-G 76 AS200-R 76 BDST3 48 BDST4 48 BE9005 94 BP120MH 76 BP189 120 BP190 76 BP880 113 BP881 113 BP980 109 BP7235 102 C10 118 C12A 118 C20 119 C23 118 C25 118 C280 118 C33 118 C345 118 C35 118 C43 118 C50 118 C75 118 C90 118 C100 119 C101 119 C115 118 C116 118 C120 119 C125 118 C190 119 C195 118 C435 119 C510 119 C520A 119 C550 118 C570 118 C781 118 C789 118 C800 119 C1600 119 CXT80 119 CXT170 119 CXT280 119 DMS 0100/INST 48 DMS 0702/PAT 48 DMS COMPL PROF 48 DP120 76 Model Page EI-1623 40 EI-1625 40 EI-162BN 40 ES-162P3 40 ES-162P4 40 ES165X (1653) 48 EXTL100 48 FLK-075-CLKT 59 FLK-100-CLKT 59 FLK80P1 56 FLK80P3 56 FLK-LENS-TELE1 61-63 FLK-LENS-WIDE 61-63 FLK-Ti-SPB3 61-63 FOM 120 FOS 850 120 FOS 1300 120 FS17XX 88 FTP SureGrip fused test probes 111 FTPL SureGrip fused test probes with leads 111 FVF- Basic 120 FVF-SC1 120 FVF-SC2 120 FVF-SC4 120 FVF-SC5 120 FVF-UG 120 GPS430 83 H3 119 H5 119 H6 119 H80M 119 H900 110 i1A/10A Clamp PQ3 88 i1A/10A Clamp PQ4 88 i5A/50A Clamp PQ3 88 i5A/50A Clamp PQ4 88 i5s 114 i20/200A Clamp PQ3 88 i20/200A Clamp PQ4 88 i30 115 i30s 115 i50s 114 i200 114 i200s 114 i310s 115 i400 114 i400s 114 i410 115 i410 Kit 115 i430-flex-4pk 88 i5sPQ3 88 i800 114 i1000s 114 i1010 115 i1010 Kit 115 i2000flex 114 i3000flex 114 i3000s 114 i6000s flex 114 IP-200-UK 59 IR 189USB 120 L200 121 L205 121 L206 121 L210 121 L215 111 LVD1 32 LVD2 32 MC6 121 MC50 121 MTC1363 (UK) 48 MTC77 (Europa) 48 OC4USB 76 PAC91 76 PASS560R 48 PM8918/301 76 PM9080 76 PM9081 76 PM9082 76 PM9090 76 PM9091 76 PM9092 76 PM9093 76 PM9094 76 PT12 68 Model Page PV350 113 RPM80 113 RS200 76 SCC120 73 SCC128 113 SCC190 75 SCC191 75 SCC198 113 SM100 32 SM200 32 SM300 32 SP1000 48 SP-Scan-15 48 SV225 121 SW90W 75 Ti-Car Charger 60-63 Ti-SBC3 61-63 Ti-TRIPOD 60-63 Ti-Visor 60-63 TL175 112 TL27 110 TL28A 113 TL2X4W-PT-II 23-24 TL2X4W-TWZ 23-24 TL40 109 TL71 110 TL75 110 TL76 110 TL80A 109 TL81A 109 TL82 113 TL220 110 TL221 110 TL222 110 TL223 110 TL224 110 TL225 121 TL238 110 TL910 109 TL930 109 TL932 109 TL935 109 TL940 109 TL950 109 TL960 109 TL970 109 TLK-220 110 TLK-225 111 TLK281 113 TLK282 113 TLK287 109 TLK289 111 TLK290 111 TLK291 111 TP1 111 TP2 111 TP4 111 TP38 111 TP40 113 TP74 111 TP80 111 TP81 113 TP82 113 TP84 113 TP88 113 TP220 111 TP912 109 TP920 109 TPAK 120 TPS Clamp 50A / 5A 87 TPS Clamp 200A / 20A 87 TPS FLEX 18 87 TPS FLEX 24 87 TPS FLEX 36 87 TPS Shunt 5 A 87 TPS Shunt 20 MA 87 TPS Voltprobe 1 KV 87 TPS Voltprobe 10 V 87 TPS Voltprobe 100 V 87 TPS Voltprobe 400 V 87 TPS Voltprobe 600 V 87 VPS40 76 VPS210-R/G series 76 Fuse and Warranty Information Product Warranty Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service, for the warranty period listed unless local law requires a longer period. The warranty period is listed in the ordering information section of the product specification and begins on the date of shipment. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke’s opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Lifetime Warranty Fuse Replacement Information A 63mA (slow) 125mA (slow) 250mA (slow) 315 mA 440mA 500mA 630mA 1A 1A 1.25A 3.15A 11A 11A 15A 20A V 250V 250V 250V 1000V 1000V 250V 250V 600V 500V 600V 500V 1000V 1000V 600V 600V Size Part nr in mm qty 1 6.35x32 163030 6.35x32 166488 6.35x32 166306 10KA 6.35x32 2279339 10kA 10.3x34.9 943121 1500A 5x20 838151 1500A 5x20 740670 10kA 10.3x34.9 830828 50kA 6.35x 32 2530449 6.35x32 2040349 6.35x32 2030852 17kA Replaced by 11A, 1000V, 20kA fuse; 803293 20kA 10.3x38.1 803293 100kA 10.3x38.1 892583 Replaced by 15A, 600V, 100kA fuse; part nr. 892583 IR See the back of your Fluke test tool or user manual for the fuses installed. For manuals check the Fluke website in the product section. For Fuse Replacement Guide check the Fluke website in the service section. Each Fluke 20, 70, 80, 170, 180 and 280 Series DMM purchased after October 1, 1996 will be free from defects in material and workmanship for its lifetime. This warranty does not cover fuses, disposable batteries and damage from accident, neglect, contamination, misuse or abnormal conditions of operation or handling, including overvoltage failures caused by use outside the DMM’s specified rating, or normal wear and tear of mechanical components. This warranty covers the original purchaser only and is not transferable. For ten years from the date of purchase, this warranty also covers the LCD. Thereafter, for the lifetime of the DMM, Fluke will replace the LCD for a fee based on then current component acquisition costs. To establish original ownership and prove date of purchase, please complete and return the registration card accompanying the product. Service Fluke will, at its discretion, repair at no charge, replace or refund the purchase price of a defective product purchased through a Fluke authorized sales outlet and at the applicable international price. Fluke reserves the right to charge for importation costs of repair/replacement parts if product purchased in one country is sent for repair elsewhere. Send defective product with a description of the problem to the nearest Fluke Authorized Service Center, postage and insurance prepaid. Fluke will pay return transportation for product repaired or replaced inwarranty. Before making any non-warranty repair, Fluke will estimate cost and obtain authorization, then invoice you for repair and return transportation. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO EXTEND ANY DIFFERENT WARRANTY ON FLUKE’S BEHALF. Since some states do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. 123 Fluke Precision Measurement products Total Solutions in Precision Measurement Catalog A variety of products covering DC/LF Electrical Calibration, Power Calibration, Calibration Software, Pressure Calibration, Time and Frequency, Temperature and Humidity Calibration including Hart Scientific, as well as Data Acquisition and Gener al Purpose Test products like arbitrary waveform generators and VXI products. To get a copy, please click “Request a catalog” on your local Fluke web site. About Fluke Networks Fluke Networks provides innovative solutions for the installation and certification, testing, monitoring and analysis of copper, fiber and wireless networks used by enterprises and telecommunications carriers. The company’s comprehensive line of Network SuperVision™ Solutions provide network installers, owners, and maintainers with superior vision, combining speed, accuracy and ease of use to optimize network performance. Headquartered in Everett, Washington, the company distributes its products in more than 50 countries. More information can be found by visiting Fluke Networks’ Web site at www.flukenetworks.com Fluke. Keeping your world up and running. ® 124
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : dtp1 Create Date : 2010:04:26 15:58:45+02:00 Modify Date : 2010:04:26 15:58:45+02:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Producer : Acrobat Distiller 9.3.2 (Macintosh) Format : application/pdf Creator : dtp1 Title : TTC-2010_Cover-Backcover-ENG.indd Creator Tool : Adobe InDesign CS4 (6.0.4) Metadata Date : 2010:04:19 10:57:51+02:00 Document ID : uuid:ce3aaa0b-4a0c-9c4e-81f2-24bbaa66c672 Instance ID : uuid:62c7c05a-5da6-614b-933c-4a2be9ce8252 Page Count : 125EXIF Metadata provided by EXIF.tools