Digital Multimeters
Clamp Meters
Electrical Testers
Insulation Testers
Earth Ground Testers
Installation Testers
Portable Appliance Testers
Digital Thermometers
Thermal Imagers
Distance Meters
Indoor Air Quality Tools
Test Tools Catalog 2010/2011

Fluke. Keeping your world
up and running.®

ScopeMeter® Test Tools
Power Quality Tools
Vibration Tester
Field Calibrators
EX Test Tools
Accessories

Fluke Corporation
P.O. Box 9090
Everett, WA USA 98206

Web: www.fluke.com
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands

Web: www.fluke.eu
For more information call:
In the U.S.A. (800) 443-5853
or Fax (425) 446-5116
In Europe/M-East/AFrica +31 (0)40 2 675 200)
or Fax +31 (0)40 2 675 222
In Canada (905) 890-7600
or Fax (905) 890-6866
From other countries +1 (425) 446-5500
or Fax +1 (425) 446-5116

Fluke (UK) Ltd.
52 Hurricane Way
Norwich
Norfolk
NR6 6 JB
United Kingdom
Tel.: (020) 7942 0700
Fax.: (020) 7942 0701
E-mail: industrial@uk.fluke.nl

Web: www.fluke.co.uk
© Copyright 2010, Fluke Corporation.
All rights reserved.
Printed in the Netherlands, 04/10
Data subject to alteration without notice.
Pub_ID: 11605-eng

Test Tools Catalog

2010/2011

Contents
Fluke web and electronic newsletter .................................................... 1
New from Fluke........................................................................................ 2-3
Fluke Combo Kits..................................................................................... 4-5

Application/background articles ...................................................... 6
Fluke After Sales Service ................................................................. 7
Fluke where safety is built in .......................................................... 8-9
Fluke Industrial Portal ..................................................................... 10
Fluke Electrical Portal....................................................................... 11
Fluke Process Portal.......................................................................... 12

Digital Multimeters ............................................................................ 13
DMM Selection Guide ....................................................................... 14
280 Series Digital Multimeters ....................................................... 15
233 Remote Display Multimeter ...................................................... 16
80 Series V Digital Multimeters ....................................................... 17
170 Series Digital Multimeters ........................................................ 18
110 Series II Digital Multimeters ..................................................... 19
77 IV Digital Multimeter ................................................................... 20
27 II/28 II Rugged Industrial Multimeters ..................................... 21
88V Automotive Meter...................................................................... 22
8845A/8846A 6.5 Digit Precision Multimeters ............................... 23
8808A 5.5 Digit Multimeter .............................................................. 24

Clamp Meters and Electrical Testers ................................................ 25
330 Series/902 Clamp Meters........................................................... 26
320 Series Clamp Meters .................................................................. 27
353/355 AC/DC Clamp Meters .......................................................... 28
360 Current Leakage Clamp Meter ................................................. 29
T100 Series Voltage/Continuity Testers .......................................... 30
T5/T5-H5-1AC Kit Electrical Testers................................................ 31
1AC-I/1AC-II/LVD1/LVD2 Voltage Detectors ................................... 32
9040/9062 Phase Rotation Indicators.............................................. 33
2042 Cable Locator ............................................................................ 34

Insulation Testers/Earth Ground Testers ......................................... 35
Insulation Tester Selection Guide ................................................... 36
1577/1587 Insulation Multimeters .................................................. 37
1503/1507 Insulation Testers ........................................................... 38
1550B MegOhmMeter........................................................................ 39
1620 Series Earth Ground Testers ................................................... 40
1621 Earth Ground Tester ................................................................. 41
1630 Ground Loop Tester .................................................................. 42

Laser Distance Meters ....................................................................... 64
421D/416D/411D Laser Distance Meters ........................................ 65

Indoor Air Quality Tools .................................................................... 66
975 Air Meter...................................................................................... 67
922 Airflow Meter .............................................................................. 68
971 Temperature Humidity Meter................................................... 69
983 Particle Counter .......................................................................... 70

ScopeMeter® Test Tools...................................................................... 71
ScopeMeter Test Tools ...................................................................... 72
120 Series ScopeMeters .................................................................... 73
190C Series, 215C/225C ScopeMeters ............................................ 74-75
ScopeMeter Accessories ................................................................... 76

Power Quality Tools ........................................................................... 77
Power Quality Selection Guide ........................................................ 78
1710 Plug-in Voltage Quality Recorder ......................................... 79
345 Power Quality Clamp Meter ...................................................... 80
43B Single-phase Power Quality Analyzer ..................................... 81
430 Series Three-phase Power Quality Analyzers......................... 82-83
1735 Power Logger ............................................................................. 84
1740 Series Power Quality Loggers.................................................. 85
1750 Power Recorder ......................................................................... 86
1760 Power Quality Recorder ........................................................... 87
Power Quality Current Clamp Accessories .................................... 88
Norma 4000/5000 Series ................................................................... 89-90

Field Calibrators ................................................................................. 91
Field Calibrator Selection Guide...................................................... 92
740 Series Documenting Process Calibrators ................................ 93
726/725/725Ex Multifunction Process Calibrators ....................... 94
724 Temperature Calibrator ............................................................. 95
712/714 Temperature Calibrators .................................................... 96
9140X/418X Drywells/IR Calibrators ............................................... 97
717/718/718Ex Pressure Calibrators ................................................ 98
706/707/707Ex/715 Loop Calibrators ............................................... 99
771/772/773 mA Clamp Meters....................................................... 100
787/789 ProcessMeters...................................................................... 101
Process Tools Accessories................................................................. 102

Vibration Tester.................................................................................. 103
810 Vibration Tester .......................................................................... 104
Installation Testers/Portable Appliance Testers .............................. 43
1650B Series Multifunction Installation Testers ........................... 44-45
6000 Series Portable Appliance Testers .......................................... 46-47
1650B/6000 Series Accessories ........................................................ 48

Digital Thermometers ....................................................................... 49
Infrared Thermometer Selection Guide ......................................... 50
570 Series Precision Infrared Thermometers ................................ 51
60 Series Infrared Thermometers ................................................... 52
566/568 Multipurpose Thermometers ............................................ 53
561 Multipurpose Thermometer ..................................................... 54
50 Series Thermometers .................................................................. 55
1523/1524 Reference Thermometers .............................................. 56

Thermal Imagers ............................................................................... 57
Ti Series Thermal Imagers ............................................................... 58
Hawk IR CRange IRWIndows ........................................................... 59
Ti19/Ti10 Electrical Thermal Imagers ............................................. 60
Ti25/Ti32 Industrial Thermal Imagers ............................................ 61
TiRx/TiR Thermal Imagers for Building Inspection ...................... 62
TiR1TiR32 Thermal Imagers for Building Diagnostics.................. 63

ATEX Certified Test Tools .................................................................. 105
A brief look at ATEX .......................................................................... 106
Fluke intrinsically safe tools............................................................ 107

General Accessories........................................................................... 108
Electronic Test Leads, Probes & Clips ............................................. 109
Industrial Test Leads, Probes & Clips.............................................. 110-111-112
Automotive Accessories ................................................................... 113
Current Clamps ................................................................................. 114-115
Temperature Accessories ................................................................. 116-117
Cases and Holsters............................................................................ 118-119
Software and Other Accessories ..................................................... 120
Other Accessories.............................................................................. 121
Product Quick Find List .................................................................... 122
Fuse and Warranty Information...................................................... 123

Fluke. Keeping your world
up and running

See page 122 for a Product Quick Find List per model number

New from Fluke

Fluke 233 Remote Display Multimeter
The Fluke 233 allows you to be in two places at once. The removable
display solves the problem of holding both the meter and the test leads
to make a measurement.
See page 16.

Fluke 27 II/28 II Rugged Industrial Multimeters
The Fluke 27 II and 28 II define a new standard for operating in harsh
conditions with the features are accuracy to troubleshoot most electrical
problems. Both multimeters have IP67 rating.
See page 21.

Fluke RLD2 Leak Detector Flashlight
The Fluke RLD2 UV Flashlight uncovers refrigerant leaks instantly.
Use the UV light to find the leakage area, then, use the laser pointer to
pinpoint the exact leak location.
See page 70.

Fluke Ti32/Ti9 Industrial Thermal Imagers
The Ti32 with its 320x240 sensor is the tool built for top professionals
who need to see the smallest details. The affordable Fluke Ti9 puts the
power of thermal imaging into the hands of electricians and technicians
who are most familiar with the installations.
See page 60 and 61.

Fluke TiR32/TiRx Thermal Imagers for Buildings
The Fluke TiR32 with its 320x 240 sensor features the highest level of
thermal sensitivity to identify even small temperature differences. This
makes it the ideal tool for building diagnostics. The Fluke TiRx is the
perfect affordable thermal imager for building inspection.
See page 62 and 63.

Hawk-IR CRange IRWindows
These arc-resistant, outdoor certified, infrared windows allow thermal,
ultraviolet, visual and fusion technologies to be used without exposing
personnel to live equipment.
See page 59.

2

New from Fluke

Fluke 1750 Power Recorder
With its exclusive threshold-free measurement system, the Fluke 1750
Power Recorder captures every measurement, every event, on every cycle,
all the time. Outstanding accuracy and resolution provide complete
visibility into your installation or distribution system.
See page 86.

Fluke 421D Laser Distance Meter
The Fluke 421D brings greater distance and advanced features to the
Fluke laser distance meter family. It can measure a distance up to 100
m with 1/16 in accuracy and has a 45º tilt sensor for taking indirect
measurements in hard to reach areas.
See page 65.

Fluke 772/773 Milliamp Process Clamp Meters
The Fluke 772 and 773 measure 4 to 20 mA signals without “breaking the
loop”, just like the popular Fluke 771. Now technicians in process plants,
industrial plants, commercial buildings and automotive repair shops can
choose exactly the range of capabilities they need, at a price that makes
sense.
See page 100.

Fluke 810 Vibration Tester
The Fluke 810 Vibration Tester is the most advanced troubleshooting
tool for mechanical maintenance teams who need an answer now. The
unique diagnostic technology helps you quickly identify and prioritize
mechanical problems, putting the expertise of a vibration analyst in your
hands.
See page 104.

FTPL Fused Test Probe Set
The FTPL are test probes with built-in fuses for additional measurement
protection. And, if the probe fuse does blow, these probes will still
allow the meter to indicate live voltage helping to prevent a possible
misreading of no voltage present.
See page 111.

80PK-18 Pipe Clamp Temperature Probe Kit
The 80PK-18 combines the standard 80PK-8 pipe clamp with the new
larger sized 80PK-10 pipe clamp, to give you a full range of measurement
sizes. The 80PK-10 can measure on pipe diameters van 32 mm to 64 mm.
See page 116 and 117.

3

Fluke Combo Kits

Buy a Combo Kit and save
Fluke 117/322 Kit
Electrician’s Combo Kit
• Fluke 117 True RMS
Multimeter
• Fluke 322 Clamp Meter
• TL75 Hard Point Test Lead Set
• TPAK Magnetic Hanger
• C115 Deluxe carrying case
with shoulder strap

Fluke 179/TPAK
179/ToolPak Combo Kit

Fluke 117/322 Kit
Fluke 179/TPAK
Fluke 179/61 Kit
Fluke 179/MAG2 Kit
Fluke 179/EDA2 Kit
Fluke 87V/E2
Fluke 87V/i410

4

• Fluke 179 True RMS
Multimeter
• TL224 SureGrip™ Silicone Test
Lead Set
• AC220 SureGrip™ Alligator
Clip Set
• TP4 Slim Reach Test Probe Set
(4 mm)
• TPAK Magnetic Hanger
• 80BK-A Integrated DMM
Temperature Probe
• C35 Soft Meter Case
• + Maglite flashlight

Fluke 179/EDA2 Kit
Electronics Combo Kit

• Fluke 179 True RMS
Multimeter
• TPAK ToolPak Meter Hanging
Kit

• Fluke 179 True RMS
Multimeter
• TL224 SureGrip™ Silicone Test
Lead Set
• TL910 Electronic Test Probe
Set
• AC280 SureGrip™ Hook Clip
Set
• TPAK Magnetic Hanger
• 80BK-A Integrated DMM
Temperature Probe
• C35 Soft Meter Case

Fluke 179/61 Kit
Multimeter and Infrared
Thermometer Combo Kit

Fluke 87V/E2
Industrial Electrician
Combo Kit

• Fluke 179 True RMS
Multimeter
• Fluke 61 Infrared
Thermometer
• C550 Hard Meter and
Accessory Case

Ordering Information

Fluke 179/MAG2 Kit
Industrial Combo Kit

• Fluke 87V True RMS
Multimeter
• TL224 SureGrip™ Silicone Test
Lead Set
• TP38 Slim Reach Test Probe
Set (insulated)
• AC220 SureGrip™ Alligator
Clip Set
• TPAK Magnetic Hanger
• 80BK-A Integrated DMM
Temperature Probe
• C35 Soft Meter Case

Fluke 87V/i410
Combo Kit for Industrial
Applications
• 87V Industrial Multimeter
• TL75 Test Leads
• AC72 Alligator Clips
• i410 400A AC/DC Current
Clamp
• 80BK-A Temperature Probe
• C115 Soft Carrying Case
(Not available in all countries)

Fluke Combo Kits

Buy a Combo Kit and save
Fluke 287/FVF FlukeView
Forms Combo Kit
• Fluke 287 True RMS Electronic
Logging Multimeter with
TrendCapture
• FVF-SC2 FlukeView Forms
Software and cable
• 80BK-A Thermocouple Probe
• CAT III 1000 V 10 A Modular
Test Leads (red, black)
• CAT II 300 V 5 A Alligator Clips
(red, black)
• C280 Soft Case for meter
protection and accessory
storage

Fluke 1587/MDT
Advanced Motor & Drive
Troubleshooting Kit
• Fluke 1587 Insulation
Multimeter
• Fluke 9040 Phase Rotation
Indicator
• I400 Current Clamp
Fluke 1587/MDT

Fluke T5-H5-1AC Kit
Fluke 289/FVF Industrial
Logging Multimeter and
Software Combo Kit
• Fluke 289 True-RMS
Multimeter
• FVF-SC2 FlukeView Forms
Software and cable
• TL71 Silicon Test Lead Set
• AC72 Alligator Clips
• 80BK-A Integrated DMM
Temperature Probe
• TPAK Magnetic Meter Hanger
for hands-free operation
• C280 Soft Case for meter
protection and accessory
storage

• Fluke T5-1000 Electrical Tester
• H5 Holster
• 1AC-II Volt Alert

Fluke T5-600/62/IAC Kit
• Fluke T5-600 Electrical Tester
• Fluke 62 Mini IR Thermometer
• Fluke 1AC-II Volt Alert
• C115 Soft Meter Case

Fluke 1587/ET Advanced
Electrical Troubleshooting Kit
• Fluke 1587 Insulation Multimeter
• Fluke 62 Mini Infrared
Thermometer
• I400 Current Clamp

Fluke 62/322/1AC Kit
• Fluke 62 Mini IR Thermometer
• Fluke 322 Clamp Meter
• Fluke 1AC-II Volt Alert

Ordering Information
Fluke 287/FVF
Fluke 289/FVF
Fluke 1587/ET
Fluke 1587/MDT
Fluke T5-H5-1AC Kit
Fluke T5-600/62/IAC Kit
Fluke 62/322/1AC Kit
Fluke 411D/62 Kit

Fluke 411D/62 Kit
• Fluke 411D Laser Distance
Meter
• Fluke 62 Mini IR Thermometer
• Soft case for each model

5

Application/
background articles
As part of our commitment to supporting you in your work we do
more than just design and manufacture rugged and versatile test tools:
we also provide application notes which all can be downloaded from
our web site. Furthermore check our three new dedicated web portals:
Industrial Portal, Electrical Portal and Process Portal. In addition to
inspection tips and helpful application information, the portals also
offer advice on picking the right tool for the job.

6

Let Fluke After Sales Service
help you further

Did you know that the Fluke after sales
service team can offer you much more
than just repairing and calibrating your
instrument when it is needed? Across
our whole Fluke European service
organization we have a vast range of
capabilities, which can be utilized via
your local service centre. Behind the
scenes Fluke draws on the expertise of
over 150 service staff that are focused
on offering only the best and most
comprehensive after sales service.

What other value added services do
we offer?

So why should you use Fluke service?
• Original manufacturers’ parts used
• All instruments reviewed for latest updates
• Repair warranty that covers whole unit
• In depth product knowledge
• Accredited calibrations available
• Traceable calibrations available on all
products
• Full check of unit during verification cycle
• Full safety test on mains powered units

What other instruments can we help
you with?

• Gold Support for Fluke Networks
• Gold CarePlans for calibration products
• A full range of maintenance contracts
• Extended warranty programs
• Instrument upgrades
• Option retrofits
• Asset management
• Calibration reminders

What services do we offer you?
• 5 day repairs on all current products
• 5 days or less on all calibrations (excl.
repairs)
• 3 days for all Gold CarePlan calibrations
• 1-2 days on all Networks Gold calibration
• Pick up services where available

We also offer a range of calibrations and
repairs on other manufacturer’s equipment
upon request. Manufacturers such as:
• Tektronix
• Agilent
• Bruel & Kjaer
• Philips
• Megger
• Seaward
• Kewtech
• Lecroy
• Hioki
• Yokogawa
• Druck
• Iwatzu
• plus many more ...

Fluke service centres handle a wide range
of equipment.
As part of Fluke’s continuing focus on improving
our service to our customer we now offer a
comprehensive range of repairs and calibrations
on a vast range of equipment.
Fluke manufactures equipments such as:
Fluke Brands
Fluke
Hart Scientific
Fluke Networks
Fluke Biomedical
Raytek
Reliable Power Meters
Robin
LEM Instruments
BEHA
Norma
Wavetek/Datron
Metron
DHI
Comark

On-Line booking in system
Why not use our On-Line booking in system
where you can book your unit in, get pricing
and receive a RMA number for a smooth
return.
www.fluke.com/servicerma

Instrument Types
Digital Multimeters
Electrical Standards
Biomedical Equipment
Data Loggers
Thermal Imagers
Thermometers
Pressure
Function Generators
Oscilloscopes
Installation Testers
PAT Testers
Clamp Meters
Power Analyzers
EX meters
Plus many more

Contact Information
Telephone
Telefax
Email
Address

Eindhoven
+31 (0)40 267 5300
+31 (0)40 267 5321
servicedesk@fluke.nl
Science Park 5108
Eindhoven
5692 EC Son
Netherlands

Norwich
+44 (0)1603 256620
+44 (0)1603 256688
ukservicedesk@fluke.com
52 Hurricane Way
Norwich
Norfolk
NR6 6JB
United Kingdom

Cologne
+49 (0)69 2222 20210
+49 (0)69 2222 20211
servicedeskgermany@fluke.com
Heinrich-Pesch-Str. 9-11
50739 Köln
Germany

7

Fluke: Where safety is built in

As distribution systems and loads
become more complex, the possibilities
of transient overvoltages increase.
Motors, capacitors and power conversion
equipment such as variable speed drives
can be prime generators of spikes.
Lightning strikes on outdoor transmission
lines also cause extremely hazardous
high-energy transients. If you’re taking
measurements on electrical systems,
these transients are “invisible” and
largely unavoidable hazards. They occur
regularly on low-voltage power circuits,
and can reach peak values in the many
thousands of volts. To protect you against
transients, safety must be built into the
test equipment.

Who Develops Safety Standards?
The IEC (International Electrotechnical
Commission) develops international general
standards for safety of electrical equipment
for measurement, control and laboratory
use. IEC61010-1 is used as the basis for the
following national standards:
• US ANSI/ISA-S82.01-94
• Canada CAN C22.2 No.1010.1-92
• Europe EN61010-1:2001

Overvoltage Installation Categories
IEC61010-1 specifies categories of
overvoltage based on the distance the piece
of equipment is from the power source
(see Fig. 1 and Table 1) and the natural
damping of transient energy that occurs
in an electrical distribution system. Higher
categories are closer to the power source and
require more protection.
Within each installation category there are
voltage classifications. It is the combination of
installation category and voltage classification
which determines the maximum transient
withstand capability of the instrument.
IEC 61010 test procedures take into account
three main criteria: steady-state voltage,
peak impulse transient voltage and source
impedance. These three criteria together will
tell you a multimeter’s true voltage withstand
value.

Figure 1. Understanding categories: location

of the 12 Ω test source for CAT II. The CAT III
600 V meter clearly offers superior transient
protection compared to the CAT II 1000 V
meter, even though its so-called “voltage
rating” could be perceived as being lower. See
Table 2.

Independent testing is the key to safety
compliance
How can you tell if you’re getting a genuine
CAT III or CAT II meter? Unfortunately it’s
not always that easy. It is possible for a
manufacturer to self-certify that its meter
is CAT II or CAT III without any independent
verification. The IEC (International
Electrotechnical Commission) develops and
proposes standards, but it is not responsible
for enforcing the standards. Look for the
symbol and listing number of an independent
testing lab such as UL, CSA, VDE, TÜV or other
recognized approval agency.
These symbols can only be used if the product
successfully completed testing to the agency’s
standard, which is based on national and

international standards. UL 3111, for example,
is based on EN61010-1. In an imperfect world,
this is the closest you can come to ensuring
that the meter you choose was actually tested
for safety.

Within a category, a higher working voltage”
(steadystate voltage) is associated with a
higher transient, as would be expected. For
example, a CAT III 600 V meter is tested
with 6000 V transients while a CAT III 1000 V
meter is tested with 8000 V transients.
So far, so good. What is not as obvious is the
difference between the 6000 V transient for
CAT III 600 V and the 6000 V transient for
CAT II 1000 V. They are not the same. This is
where the source impedance comes in. Ohm’s
Law (Amps = Volts/Ohms) tells us that the 2 Ω
test source for CAT III has six times the current

Table 1

8

Overvoltage category
CAT IV

In brief
Three-phase at utility connection,
any outdoor conductors

CAT III

Three-phase distribution, including
single-phase commercial lighting

CAT II

Single-phase receptable
connected loads

CAT I

Electronic

Examples
• Refers to the “origin of installation”; i.e., where low-voltage connection is made to utility power.
• Electricity meters, primary overcurrent protection equipment.
• Outside and service entrance, service drop from pole to building, run between meter and panel.
• Overhead line to d etached building, underground line to well pump.
• Equipment in fixed installations, such as switchgear and polyphase motors.
• Bus and feeder in industrial plants.
• Feeders and short branch circuits, distribution panel devices.
• Lighting systems in larger buildings.
• Appliance outlets with short connections to service entrance.
• Appliance, portable tools, and other household and similar loads.
• Outlet and long branch circuits.
• Outlets at more than 10 meters (30 feet) from CAT III source.
• Outlets at more than 20 meters (60 feet) from CAT IV source.
• Protected electronic equipment.
• Equipment connected to (source) circuits in which measures are taken to limit transient overvoltages
to an appropriately low level.
• Any high-voltage, low-energy source derived from a high-winding resistance transformer, such as the
high-voltage section of a copier.

Overvoltage installation categories. IEC 61010-1 applies to low-voltage (< 1000V) test equipment

Fluke: Where safety is built in

Safety is everyone’s responsibility but
ultimately it is in your hands.
No tool by itself can guarantee your safety
when working with electricity. It’s the
combination of the right tools and safe
work practices that gives you maximum
protection. Here are a few tips to help you
in your work:
Make sure you always comply with (local)
regulations.
Work on de-energized circuits whenever
possible.
Use proper lock-out/tag-out procedures. If these
procedures are not in place or enforced, assume
that the circuit is live.

Use protective gear when working on live
circuits:
• Use insulated tools
• Wear safety glasses or a face shield
• Wear insulated gloves, remove watches or
jewelry
• Stand on an insulated mat
• Wear flame resistant clothing, not ordinary
work clothes

Select the right test tool:

Inspect and test your test tool:

• Choose a test tool rated to the highest
category and voltage for which it could
possibly be used (most often 600 or 1000
volt CAT III and/or 600 volt CAT IV).
• Look for the category and voltage marking
near the recessed input connectors of your
test tool and a “double insulated” symbol
on the back.
• Verify your test tool has been tested and
certified by two or more independent
testing laboratories, such as UL in the
United States and VDE or TüV in Europe by
looking for the symbols of these agencies
on (the back of) your test tool.
• Make sure that the test tool is made of
a high-quality, durable non-conductive
material.
• Check the manual to verify that the
ohms, continuity and capacitance circuits
are protected to the same level as the
voltage test circuit, to reduce hazards
when the test tool is used incorrectly in
ohms, continuity or capacitance mode (if
applicable).
• Verify that the test tool has internal
protection to prevent instrument damage
when voltage is incorrectly applied to
an amperage measurement function (if
applicable).
• Make sure that the amperage and
voltage of your test tool’s fuses meets
specifications. Fuse voltage must be as high
or higher than the test tool’s voltage rating.
• Be sure to use test leads that have:
- Shrouded connectors
- Finger guards and a non-slip surface
- Category ratings that equal or exceed
those of the test tool
- Double insulation (look for the symbol)
- A minimum of exposed metal on the
probe tips

• Check for a broken case, worn test leads or
a faded display.
• Make sure the batteries still deliver
sufficient power to get reliable readings.
Many test tools have a low battery indicator
on the display.
• Check the test leads resistance for internal
breaks while moving the leads around
(good leads measure 0.1-0.3 Ohm).
• Use the meter’s own test capability to
ensure that the fuses are in place and
working right (see manual for details).

Apply the appropriate working
practices when measuring on live
circuits:
• Hook on the ground clip first, then make
contact with the hot lead. Remove the hot
lead first, the ground lead last.
• Use the three-point test method, especially
when checking to see if a circuit is dead.
First test a known live circuit. Second,
test the target circuit. Third, test the live
circuit again. This verifies that your test
tool worked properly before and after the
measurement.
• Hang or rest the test tool if possible.
Try to avoid holding it in your hands, to
minimize personal exposure to the effects
of transients.
• Use the old electrician’s trick of keeping
one hand in your pocket. This lessens the
change of a closed circuit across your chest
and through your heart.

For more information or to see the Electrical Safety video go to:
United Kingdom: www.fluke.co.uk/safety
Ireland: www.fluke.ie/safety
E-Europe/Middle-East/Africa: www.fluke.nl/safety_ex

Use protective equipment such as safety glasses and
insulated gloves

Table 2
Overvoltage
Installation
Category
CAT I
CAT I
CAT II
CAT II
CAT III
CAT III
CAT IV

Use meters with these markings:
1000 V CAT III or 600 V CAT IV

Working Voltage
(DC or AC RMS
to ground)
600 V
1000 V
600 V
1000 V
600 V
1000 V
600 V

Peak Impulse
Transient
(20 repetitions)
2500 V
4000 V
4000 V
6000 V
6000 V
8000 V
8000 V

Test Source
(Ω = V/A)
30 Ohm source
30 Ohm source
12 Ohm source
12 Ohm source
2 Ohm source
2 Ohm source
2 Ohm source

Transient test values for overvoltage installation categories.
(50 V/150 V/300 V values not included)

9

Fluke Industrial Web Portal
Reduce downtime and unnecessary repairs

Motors & drives

Automation systems

Power distribution

Plant infrastructure

Heavy loads

Worn
bearings

Incorrect
motor

Wrong
motor/drive
connections

Unbalanced
harmonics

Cable/
connection
damage

Equipment
end-of-life

Lack of
maintenance

Incorrect motor
Overloading and mechanical strain could be signs that the motor is underperforming or inadequate for the job.
Use an infrared thermometer to quickly locate hot spots, and see areas of excessive heat with a thermal imager to determine severity. A digital
multimeter will determine if the current draw is too high, which is also a sign that the motor is inadequate for the demands placed on it. With
a clamp meter measure the inrush current and high load currents.

Fluke 568 Thermometer

Fluke Ti32 Thermal Imager

• High accuracy
• Easy interface
• Infrared and contact bead probe
• Trending and reporting via PC

• 320 x 240 sensor for clear, crisp images
• IR-Fusion® blended thermal images
• Rugged, withstands 2 m drop
• High resolution and thermal sensitivity
• Full analysis and reporting software
included

Fluke 87V True RMS Multimeter

Fluke 337 True RMS Clamp Meter

• Accurate frequency and voltage
measurements on motor drives and
electrically noisy environments.
• Built-in thermometer

• In-rush current function for motor
starting, inductive lighting, etc.
• AC/DC voltage and frequency
measurements
• Jaw opening 42 mm

www.fluke.eu/industrial
Visit the full portal with practical information about troubleshooting potential problems throughout the plant.
See how to find the right test tool for the job.

10

Fluke Electrical Web Portal
A solution for every application

Electrical installation testing

Power consumption

Service/repair

Electrical Installation Testing
Setting up new installations, extending an existing installation or trouble shooting around safety is always crucial. To avoid any safety issues,
with a multifunctional installation tester all safety measurement are combined in one single tester, testing a RCD or measuring the loop etc.
A voltage tester is the every day tester when working in an electrical installation, quickly check voltage or continuity. The T5 with its
OpenJawTM technology allows current measurement on tight spaces such as for example on a distribution board.

Fluke 1650B Series
Installation Testers
• Insulation test, continuity test, high
current loop test, RCD test, earth ground
test
• Slim probe with test button

Fluke T5-1000 Electrical Tester
• Voltage and continuity measurement
• OpenJaw™ technology for current
checks up to 100 A

Fluke T120 Voltage and
Continuity Tester
• Voltage, continuity and resistance
measurements
• Three-phase rotation detection system

www.fluke.eu/electrical
Visit the full portal with practical information for the electrical installer.
See how to find the right test tool for the job.

11

Fluke Process Web Portal
Identifying potential problems
Testing in Ex. Classified areas

Automation Systems

Maintenance and calibration
of process instruments

Instrument commissioning
and service

Measuring,
troubleshooting
4-20mA loop
signals

Temperature
calibrations

Pressure
calibrations

Switch testing

Custody transfer

Troubleshooting
process signals

Measuring troubleshooting 4-20 mA loop signals
Keeping manufacturing and processing plants running at maximum efficiency 24-hours a day requires regular inspection and troubleshooting
of vital systems and equipment. 4-20mA control loops are the most common control signals used in process industries today. Troubleshooting
the mA loop instruments, connections, and cables are an essential part of locating and reparing process control.

Fluke 707Ex Loop Calibrator
• Simultaneous mA and %
• mA accuracy of 0.02%
• Measure, source and simulate mA

Fluke 725Ex Multifunction
Process Calibator
• Measure, source and view process
signals simultaneously
• Measure volts, mA, RTDs,
thermocouples, frequency, and
resistance to test sensors and
transmitters.

Fluke 87VEx True RMS Multimeter
• Accurate frequency and voltage
measurements on motor drives and
electrically noisy environments.
• Built-in thermometer

www.fluke.eu/process
Visit the full portal with practical information about troubleshooting potential problems in the process control
environment. See how to find the right test tool for the job.

12

Digital Multimeters
Safety, quality and performance: three words that sum up the benefits of
our extensive range of digital multimeters. Designed to help you do your
job faster, more efficiently and with greater accuracy, there is a model for
every budget and application. Choose from handheld troubleshooters to
ultra smart instruments packed with features, including the ability to log
and graph data, as well as high-precision bench units.

13

14

Basic features
Counts
True RMS readings
Basic DC accuracy
Wide bandwidth
Auto/manual ranging
Measurements
Voltage AC/DC
Current AC/DC
Resistance
Frequency
Capacitance
Temperature
dB
Conductance
Duty cycle/pulse width
Continuity with beeper/Diode test
4-20mA loop current as % readout
Motor drive measurement
RPM/Dwell
VoltAlertTM, Non-contact voltage detection
LoZ: low input impedance
VCHEKTM LoZ
Microamps
Insulation test
Number of insulation test ranges
Display
Dual display
Analog bargraph
Backlight
Remote display
Data storage and exchange
Min-Max recording/with time stamp
Fast Min-Max
Display Hold/Auto (Touch) Hold
Relative
Stand alone logging/TrendCapture
USB interface/RS232 interface
Readings memories
Other features
Source 4-20mA loop current/24V loop supply
Automatic selection, AC/DC volts
Real time clock
Smoothing
Integrated holster
Removable holster
Closed case calibration
Seperate battry/fuse access
Completely sealed/watertight
Automatic power off
Low battery indication
Warranty and safety
Lifetime warranty/warranty (years)
Input alert
Dangerous voltage indication
EN61010-1 CAT III
EN61010-1 CAT IV
See catalog page
287

O/O

6000
AC
0.25%

233

Remote
display

20000
AC
0.05%
20 kHz
O/O

87V

0.1%
5 kHz
O/O

6000

83V

High-end Industrial

O/O

6000
AC
0.09%

179

O/O

6000
AC
0.09%

177

O/O

6000
AC
0.15%

175

Industrial maintenance
and field service

O/O

6000
AC
0.5%

117

Electrical

O

O
O
O

O/O
250 μs
O/O
O
O/O
O/O
10000

O
O
O
O/O
O
O
O
O
O
1000 V
600 V
15

O
O
O

O/O
250 μs
O/O
O
O/O
O/O
10000

O

O

O
O/O

O
O

O
O
O
1000 V
600 V
15
O
1000 V
600 V
16

3

O
O/O

O

O

O

O
O

O
O
O
1000 V
600 V
17

O
O

O
O
O/-

O/250 μs
O/O
O

O
O

O

O

O
O
O
1000 V
600 V
17

O
O

O
O
O/-

O/O
O

O/-

O
O

O

O
1000 V
600 V
18

O

O
O

O
O/O

O
O

O/O

O/-

O
O

O
1000 V
600 V
18

O

O
O

O
O/O

O
O

O/O

O/-

O
O

O
1000 V
600 V
18

O

O
O

O
O/O

O
O

O/O

O/-

O

O
600 V
19

19

3

O
O

O
600 V

3

O
O

O
O
O/-

O

O

O
O
O/-

O/-

O/-

O
O

O

19

O
600 V

3

O
O

O
O
O/-

O/-

O/-

O
O

O/O

O/O

O

600 V
10 A
40 MΩ
50 kHz
10 mF

O/O

6000
AC
0.5%

115

Field
Service

600 V
200 μA
40 MΩ
50 kHz
10 mF
+400ºC

O/O

6000
AC
0.5%

116

HVAC/R

O/-

O/-

O
O

O
O

1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
600 V
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
500 MΩ 40 MΩ 50 MΩ 50 MΩ 50 MΩ 50 MΩ 50 MΩ 40 MΩ
1 MHz 50 kHz 200 kHz 200 kHz 100 kHz 100 kHz 100 kHz 50 kHz
100 mF 10 mF
10 mF
10 mF
10 mF
10 mF
10 mF
10 mF
+1350ºC +400ºC +1090ºC
+400ºC
60 dB
50 nS
60 nS
60 nS
O/O
O/O/O/O
O/O
O/O
O/O
O/O
O/O
O/O
O/O

O

O

O

1000 V
10 A
500 MΩ
1 MHz
100 mF
+1350ºC
60 dB
50 nS
O/O
O/O

50000
50000
AC+DC AC+DC
0.025% 0.025%
100 kHz 100 kHz
O/O
O/O

289

Highest accuracy

113

19

O
600 V

3

O
O

O
O
O/-

O

O/-

O/-

O
O

O

O/-

60 kΩ

40 MΩ

19

O
600 V

3

O
O

O
O
O/-

O/-

O/-

O
O

O

O/O

10 mF

600 V

O/O

6000
AC
2.0%

600 V

O/O

6000
AC
0.5%

114

Basic Electrical

28II

20000
AC
0.05%
50 kHz
O/O
O/O

0.3%

6000

77IV

General
Purpose

O/O

0.1%

20000

88V

Automotive

O/O

4000
AC
0.1%

789

O
O
O
1000 V
600 V
21

O
O
O/O
O
O
O

O/O
O

O/-

O
O

60 nS
O/O
O/O

O
O
O
1000 V
600 V
21

O
O
O/O
O
O
O

O/250 μs
O/O
O

O
O

O

60 nS
O/O
O/O

O
1000 V
600 V
20

O

O
O

O

O

-/O

O/-

O
O

O/O

O
O
O
1000 V
600 V
22

O
O

O
O
O/-

O/250 μs
O/O
O

O
O

O/-

60 nS
O/O
O/O

101

1000 V

3

O
O

O
O/O

O

O/O

O/O

-/O
O

O/-

O
O
O

O/O
O

O/O

6000
AC
0.09%

1587

O/O

6000
AC
0.2%

1577

Insulation test

101

1000 V

3

O
O

O/-

O

O/-

-/O
O

O/-

O

O

O/O
O

O
1000 V
600 V
37

3

O
O

O
O
O/O

O

O/O

O/-

O

O
5

O

O/O

O
1000 V
600 V
37

3

O
O

O
O
O/O

O

O
2

O/-

1000 V 1000 V 1000 V
1A
400 mA 400 mA
40 MΩ 50 MΩ 50 MΩ
20 kHz 100 kHz
10 mF
+500ºC

O/O

4000
AC
0.1%

787

Loop calibration

1000 V 1000 V 1000 V 1000 V 1000 V
10 A
10 A
10 A
10 A
1A
50 MΩ 50 MΩ 50 MΩ 50 MΩ 40 MΩ
200 kHz 200 kHz 100 kHz 200 kHz 20 kHz
10 mF
10 mF
10 mF
10 mF
+1090ºC
+1090ºC

0.1%
20 kHz
O/O

6000

27II

Heavy duty
(IP67)

DMM Selection guide

280 Series Digital Multimeters
Advanced diagnostic and logging
functionality for maximizing productivity
Replacing the popular 180 Series, the
Fluke 289 and Fluke 287 represent the
next generation of high-performance
industrial logging multimeters,
including higher accuracy and greater
troubleshooting convenience than ever
before. With the ability to log data and
review it graphically on the large display,
you can solve problems faster and help
minimize downtime, while working at
several locations.
• Large 50,000 count 320 x 240 (1/4 VGA)
dot matrix display

• Logging function with TrendCapture for
easy review of logged data
• Multiple readings per display provide
more information at a glance
• “I”-info button for convenient on-board
help
• PC interface for easy data transfer
In addition, the Fluke 289 provides:
• Lo Pass filter for motor drive
measurements
• LoZ – Low impedance function prevents
false “ghost voltage” readings
• 50 Ω range for motor winding and low
ohm measurements

Features

Fluke 289
287

289

AC, AC+DC

AC, AC+DC

100 kHz / 100 kHz

100 kHz / 100 kHz

50.000 / 50.000

50.000 / 50.000

O
O

O
O

Up to 180 h

Up to 180 h

O
O

O
O
O

True-RMS measurements
Bandwidth (voltage/current)

Fluke 287

Digital display counts (default/selectable)
Logging function with TrendCapture
Records events and trends
Internal memory
Saves measurements
Optical USB PC communications interface
Low input impedance function (LoZ)
Motor winding and low ohm measurement range

50 Ω

O
O
O
O
O
O
O
O
O
O
O
O

Low pass filter

O
O
O
O
O
O
O
O
O
O
O

Field upgradeable/expandable meter
Navigation keys
F1-F4 soft keys/user function menus
I-info button/on board help screens

Precise performance

View logged data graphically
on screen

Multilingual interface
Saves preferred measurement setups
Current measurement: 20 A (30 seconds momentary; 10 A continuous)
Peak capture (records transients as fast as 250 μs)
Continuity measurement
Min/Max/Average with Time Stamp (records signal fluctuations)
IP Rating 54

Specifications
(Check the Fluke web for detailed specifications)
True RMS

Included Accessories
TL71 silicone test leads, probe holder, 6 AA
batteries (installed), user manual, Calibration
Certificate Sheet.

Ordering Information
Fluke 287

True-RMS Electronic logging
multimeter with TrendCapture
Fluke 289
True-RMS Industrial logging
multimeter with TrendCapture
Fluke 289/FVF Industrial logging multimeter
and Software Combo Kit
(see page 5)
Fluke 287/FVF FlukeView Forms Combo Kit
(see page 5)
FVF-SC2
FlukeView Forms software
including IR/USB cable

Functions

Maximum

Max. resolution

287 and 289**

Voltage DC

1000 V

1 μV

±(0.025% + 5)

Voltage AC

1000 V

1 μV

±(0.4% + 40)

Current DC

10 A

0.01 μA

±(0.15% +2)

Current AC

10 A

0.01 μA

±(0.7% + 5)

Temperature

-200 ºC to 1350 ºC

0.1 ºC

±(1.0% + 1 ºC)

Resistance

500 MΩ

0.01 Ω

±(0.05% + 2)

Conductance

50 nS

0.01 nS

±(1.0% + 10)

Capacitance

100 mF

0.001 nF

±(1.0% + 5)

Frequency

1 MHz

0.01 Hz

±(0.005% + 1)

Accuracies are best accuracies for each function.
** 287 and 289 accuracy and resolution are stated for 50.000 counts

Battery life: 50 hours minimum,
180 hours in logging mode
Size (HxWxD): 222 mm x 102 mm x 60 mm

Weight: 0,871 kg
Lifetime warranty

Recommended Accessories

TLK289
See page 111

TL910
See page 109

TLK287
See page 109

TPAK
See page 109

C280
See page 118

15

233 Remote Display Multimeter
New

Ultimate flexibility with removable display
The NEW Fluke 233 remote display digital
multimeter allows you to be in two
places at once. The removable display
solves the problems of holding both
the meter and the test leads to make a
measurement, making measurements
in hard-to-reach places, and making
measurements in machines or panels
that are physically separated from a limit

switch or an isolator switch. Wireless
technology allows the display to be
carried up to 10 meters away from the
point of measurement. The Fluke 233
is also designed to work in areas where
the operator can’t be close to the active
measurement point, like clean rooms or
hazardous areas.

Features
233
Removable magnetic display

O

True-RMS measurement

O

Digital display counts

6000

Display backlight

O

Built in thermometer

O

Resistance, continuity and diode test

O

Min/Max and average recording

O

Auto power off maximizes battery life

O

Radio transmitter automatically turns off when
the display is connected to the meter

O

Use as conventional multimeter when the display is connected

O

Safety rating

CAT IV 600 V / CAT III 1000 V

Auto and manual ranging
Fluke 233

O

Display Hold and AutoHOLD

O

Unsafe voltage alert warns for voltages above 30V

O

2 Low batteries indication

O

Ergonomic case with integrated holster

O

Selectable sleep mode preserves battery life

O

®

Specifications
On all inputs
Functions

True RMS

Included Accessories
Test leads with 4mm lantern tips and
protective cap, AC 72 alligator clips, 80BK-A
temperature probe, CD-ROM, AA batteries and
user manual.

Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency
Temperature
Wireless frequency: 2.4 GHz ISM Band 10 meter range

Maximum
1000 V
1000 V
10 A
10 A
40 MΩ
9999 μF
50.00 kHz
-40 ºC to +400 ºC

Fluke 233
Max. Resolution
0.1 mV
0.1 mV
1 mA
1 mA
0.1 Ω
1 nF
0.01 Hz

Accuracy
±(0.25% + 2)
±(1.0% + 3)
±(1.0% + 3)
±(1.5% + 3)

Accuracies are best accuracies for each function

Ordering Information
Fluke 233

Remote Display Multimeter

Battery Life: AA alkaline (3 for main body,
2 for display), 400 hrs typical
Size (HxWxD): 193 x 93 x 53 mm

Weight: 0.6 kg
Three year warranty

Recommended Accessories

80AK-A
See page 116

16

80PK-9
See page 116

i410
See page 115

Tpak
See page 120

C35
See page 118

80 Series V
Digital Multimeters
Performance and accuracy for
maximum industrial productivity
The Fluke 80 Series V have improved
measurement functions, troubleshooting
features, resolution and accuracy to solve
more problems on motor drives, in plant
automation, power distribution, and
electro-mechanical equipment.

The Fluke 87V has a unique function
for accurate voltage and frequency
measurements on adjustable speed
motor drives and other electrically noisy
equipment. A built-in thermometer
conveniently allows you to take
temperature readings without having to
carry a separate instrument. For 87V Ex
see also page 106 and 107.

Features
83V

Fluke 83V

5 kHz

20 kHz

Digital display counts (default/selectable)

6000

20000 / 6000

Selectable filter for accurate voltage and frequency
measurements on motor drives
Large display with analog bargraph and 2 level bright
white backlight
Auto and manual ranging for maximum flexibility

Fluke 87V

83V/87V

87V / 87V Ex
O

True-RMS voltage and current for accurate
measurements on non linear signals
Bandwidth (voltage/current)

O
O

O

O

O

Built-in thermometer lets you carry one less tool

O

Peak capture to record transients as fast as 250 μs

O

Relative mode to remove test lead resistance from low
ohms measurements
Min-Max-Average recording with Min/Max Alert to
capture variations automatically
AutoHOLD® to capture stable readings avoiding noisy
signals
Audible continuity, diode test and duty cycle

O

O

O

O

O

O

O

O

Input Alert

O

O

“Classic” design with new removable holster with built
in test lead and probe storage
Improved selectable sleep mode for long battery life

O

O

O

O

Easy battery exchange without opening the complete
case

O

O

ATEX safety rating

87V Ex

II 2 G Eex ia IIC T4

Specifications
On all inputs

(Check the Fluke web for detailed specifications)

Fluke 87V Ex
Functions

True RMS
not 87V Ex

Included Accessories
TL75 test leads, AC72 alligator clips, yellow
holster (H80M excl. TPAK), 80BK temperature
probe (87V only), 9 V battery (installed),
CD-ROM (user’s manual and technical notes)
and operator’s guide.

Ordering Information
Fluke 83V
Multimeter
Fluke 87V
True RMS Multimeter
Fluke 87V Ex Intrinsically safe
True RMS multimeter
Fluke 87V/E2 Industrial Electrician Combo
Kit
See page 4

Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Conductance
Capacitance
Frequency
Temperature
80BK temperature probe

Maximum Range

83V

87V/87V Ex*

Max. resolution

Accuracy

Max.
resolution

Accuracy

0.1 mV
0.1 mV
0.1 μA
0.1 μA
0.1 Ω
0.01 nS
0.01 nF
0.01 Hz

±(0.1%+1)
±(0.5%+2)
±(0.4%+2)
±(1.2%+2)
±(0.4%+1)
±(1.0%+10)
±(1.0%+2)
±(0.005%+1)
-

10 μV
10 μV
0.01 μA
0.01 μA
0.01 Ω
0.001 nS
0.01 nF
0.01 Hz
0.1 ºC
-

±(0.05%+1)
±(0.7%+2)
±(0.2%+2)
±(1.0%+2)
±(0.2%+1)
±(1.0%+10)
±(1.0%+2)
±(0.005%+1)
1.0%
2.2 ºC or 2%

1000 V
1000 V
10 A **
10 A **
50 MΩ
60 nS
9999 μF
> 200 kHz
-200 to 1090 ºC
-40 to 260 ºC

Accuracies are best accuracies for each function.
* 87V accuracy is stated for 6000 counts and resolution for 20000 counts
** 20 A up to 30 seconds

Battery Life: Over 400 hours typical (alkaline).
Size (HxWxD):
200 mm x 95 mm x 48 mm

Weight: 0.6 kg
83V/87V: Lifetime Warranty
87V Ex: One Year Warranty

Recommended Accessories
(Not for hazardous zones)

C25
See page 118

TL238
See page 110

i410/i1010
See page 115

TPAK
See page 120

L215
See page 111

17

170 Series Digital Multimeters
Versatile meters for field service or
bench repair
These meters have the features needed
to find most electrical, electromechanical and heating and ventilation
problems.
They are simple to use and have
significant improvements over Fluke’s
original 70 Series like True-RMS, more
measurement functions, conformance to
the latest safety standards, and a much
larger display that’s easier to view.

Features
True-RMS measurements

175
AC

177
AC

179
AC

Digital display counts, updates 4 times per second

6000

6000

6000

O

O

Display backlight
Fluke 177

Fluke 179

Fluke 175

Analog bargraph / 33 segments, updates 40 times per
second
Auto and Manual ranging

O

O

O

O

O

O

Display Hold and AutoHOLD®

O

O

O

Min-Max-Average recording mode with Min/Max Alert

O

O

O

Temperature readings (bead thermocouple probe
included)
Smoothing mode allows filtering of rapidly changing
inputs
Audible continuity and diode test

O

O

O

O

O

O

Test lead alert

O

O

O

Unsafe voltage alert warns for voltages above 30V

O

O

O

Low battery indication

O

O

O

Ergonomic case with integrated holster

O

O

O

Easy battery and fuse exchange without opening the
complete case
Selectable sleep mode preserves battery life

O

O

O

O

O

O

O

Specifications

On all inputs

(Check the Fluke web for detailed specifications)
True RMS

Included Accessories
Test leads with 4 mm lantern tips and
protective cap, installed 9V battery and users
manual. The 179 also includes the 80BK
temperature probe.

Ordering Information
Fluke 175
Fluke 177
Fluke 179
Fluke 179/EDA2 Kit
Fluke 179/MAG2 Kit

True RMS Multimeter
True RMS Multimeter
True RMS Multimeter
Electronics Combo Kit
Industrial Combo Kit
See page 4

Functions
Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency
Temperature

Max. resolution
0.1 mV
0.1 mV
0.01 mA
0.01 mA
0.1 Ω
1 nF
0.01 Hz
0.1 ºC

175
±(0.15%+2)
±(1.0%+3)
±(1.0%+3)
±(1.5%+3)
±(0.9%+1)
±(1.2%+2)
±(0.1%+1)

177
±(0.09%+2)
±(1.0%+3)
±(1.0%+3)
±(1.5%+3)
±(0.9%+1)
±(1.2%+2)
±(0.1%+1)

179
±(0.09%+2)
±(1.0%+3)
±(1.0%+3)
±(1.5%+3)
±(0.9%+1)
±(1.2%+2)
±(0.1%+1)
±(1.0%+10)

Accuracies are best accuracies for each function

Battery Life: Alkaline, 200 hrs typical
Size (HxWxD): 190 mm x 85 mm x 45 mm

Weight: 0.42 kg
Lifetime Warranty

Recommended Accessories

i400
See page 114

18

Maximum
1000 V
1000 V
10 A
10 A
50 MΩ
10000 μF
100 kHz
-40 ºC/+400 ºC

C90
See page 118

TLK-220
See page 110

SV225
See page 121

i410-i1010
See page 115

110 Series Digital Multimeters
Compact design for ergonomic
one-handed operation
Fluke 115 Field Service Testing
Multimeter

The Fluke 110 Series has five true-rms
DMMs, each for specific users. The compact
instruments offer convenient one-handed
operation and a backlit display with large, easyto-read digits.

An everyday multimeter for technicians, the
115 is for electrical and electronic testing in
field service, industrial, and applications where
more than the basic functions simplify work.

Fluke 117 Electrician’s Multimeter with
Non-Contact Voltage

Fluke 115

Fluke 114 Electrical Multimeter

The 117 is for electricians working in
commercial and non-commercial premises
(like hospitals and schools). It includes extras
like non-contact voltage detection for faster
and safer operation.

The 114 is for electrical troubleshooting and
straightforward ‘go/no-go’ in residential/
commercial testing. It has all the basic
functions plus a special feature to prevent false
readings caused by ghost voltage.

Fluke 116 Multimeter with Temperature
and Microamps

Fluke 113 Multimeter
The 113 is for basic electrical tests and
repairing most electrical problems. Features
include Fluke’s VCHEK™, added measurement
functions, backlight and conformance to the
latest safety standards.

The 116 is for heating, ventilation and air
conditioning (HVAC) engineers. It includes
temperature measurement and microamp
current ranges to quickly troubleshoot HVAC
problems.

Fluke 117

Features
113

114

115

116

AC

AC

AC

AC

AC

6000

6000

6000

6000

6000

Backlight

O

O

O

O

O

Analog bargraph

O

O

O

O

O

True RMS readings
Counts

Fluke 114

O

AutoVolt: Automatic AC/DC voltage selection

117

O

O
O

VoltAlert™, Non-contact voltage detection

O

Built-in thermometer for HVAC applications

O

LoZ: low input impedance to prevent ghost voltage
VCHEK™ LoZ low impedance measurement function to
simultaneously test for voltage or continuity

O

Min/Max/Average to record signal fluctuations

O

O

Resistance, continuity

O

O

-/ O/O

Frequency, Capacitance, Diode test

O

O

O

O

O

O

O

O

O

O

O

O

Microamps to test flame sensors

Fluke 116

Display hold

O

O

O

O

O

Auto/manual ranging

O

O

O

O

O

Low battery indication

O

O

O

O

O

Compact case with removable holster

O

O

O

O

O

Specifications
(Check the Fluke web for detailed specifications)
Functions
Fluke 113
On all inputs

True RMS

Included Accessories

Voltage DC

Maximum
600V

Max. resolution
1mV

113

114

115

116

117

±(0.5%+2)

±(0.5%+2)

±(0.5%+2)

±(0.5%+2)

±(0.5%+2)

±(1.0%+3)

±(1.0%+3)

±(1.0%+3)

±(1.0%+3)

Voltage AC

600V

1mV

Current DC

10.00A

1mA

±(1.0%+3)

Current AC

10.00A

0.01A

±(1.5%+3)

Resistance

40MΩ (113: 60KΩ) 0.1Ω

±(0.9%+2)

Capacitance

10000μF

1nF

±(1.9%+2)

Frequency

50kHz

0.01Hz

Temperature

-40°C/+400°C

0.1°C

VCHEK™

600.0V AC/DC

0.1V

±(0.9%+1)

±(0.9%+1)

±(1.0%+3)
±(1.5%+3)
±(0.9%+1)

±(1.9%+2)

±(1.9%+2)

±(1.9%+2)

±(0.1%+2)

±(0.1%+2)

±(0.1%+2)

±(1.0%+2)

Test leads with 4 mm lantern tips and
protective cap, holster, installed 9V battery
and users manual

Accuracies are best accuracies for each function

Ordering Information

Battery type: 9 volt Alkaline, 400 hours typical Weight: 0.55 kg (including batteries)
Size (HxWxD): 167 mm x 84mm x 46 mm
Three Year Warranty

Fluke 113
Fluke 114
Fluke 115
Fluke 116
Fluke 117
Fluke 117/322 Kit

True RMS Multimeter
True RMS Multimeter
True RMS Multimeter
True RMS Multimeter
True RMS Multimeter
Electricians Combo Kit
(see page 4)

±(0.9%+1)

±(2.0%+3)

Recommended Accessories

C50
See page 118

TL223
See page 110

MC6
See page 121

TPAK
See page 120

19

77IV Digital Multimeter
Versatile multimeter for field service
or bench repair
The 77-IV digital multimeter has the
features needed to repair most electrical
and electronic problems. This meter
is simple to use and has significant
improvements over Fluke’s original
70 Series with more measurement
functions, conformance to the latest
safety standards, and a much larger
display that’s easier to view.

Features
77 IV
6000
O
O
O
31
O
O
O
O
O
CAT IV 600 V / CAT III 1000 V

Digital display counts
Large display with backlight
Min-Max-Average recording mode with Min/Max Alert
High contrast digital display with large digits
Analog bargraph/segments
Auto and Manual ranging
Automatic Touch Hold®
Audible continuity / diode test
Ergonomic case with integrated holster
Sleep Mode preserves battery life
EN 61010-1 safety rating

Fluke 77 IV

Specifications
Function
Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency

Maximum
1000 V
1000 V
10 A
10 A
50 MΩ
9999 μF
99.99 kHz

Max. resolution
1 mV
1 mV
0.01 mA
0.01 mA
0.1 Ω
1 nF
0.01 Hz

Accurancy
±(0.3%+1)
±(2.0%+2)
±(1.5%+2)
±(2.5%+2)
±(0.5%+1)
±(1.2%+2)
±(0.1%+1)

Accuracies are best accuracies for each function.

Battery Life: 400 hours typical
Weight: 0.42 kg
Size (HxWxD): 185 mm x 90 mm x 43 mm Lifetime Warranty
On all inputs

Recommended Accessories

Included Accessories
TL75 test leads, operator’s manual, 9V battery
(installed)

Ordering Information
Fluke 77IV
20

Multimeter

i400
See page 114

C35
See page 118

Tpak
See page 120

TL225
See page 121

TLK-225
See page 111

27II / 28II Rugged IP67 Industrial
Multimeters
Designed to survive water, dust and rough
handling and yet troubleshoot most electrical
problems

New

The NEW Fluke 27 II and 28 II digital
multimeters define a new standard for
operating in harsh conditions with the
features and accuracy to troubleshoot
most electrical problems. Both meters
have IP 67 (waterproof and dustproof)
rating, MSHA approvals (pending),
extended operating temperature range
of -15° C to + 55°C and 95% humidity,
and a 3-meter drop. They withstand
hazardous 8.000 volt spikes caused by

load switching and faults on industrial
circuits and complies with second edition
IEC and ANSI electrical safety standards.
Furthermore, the 28 II has a unique
function for accurate voltage and
frequency measurements on adjustable
speed motor drives and other electrically
noisy equipment.
The new Fluke 20 series multimeters
are built to work in the toughest
environments.

Features
27 II

28 II

IP 67 waterproof & dustproof protection

O

O

Withstands 3 meter drop (with holster)

O

O

True-RMS measurements
Fluke 27 II

O

Digital display counts

6000

20000/6000

Bright, two-level backlight

O

O

Backlit keypad buttons

O

O

Reversible, rubber holster

O

O

Resistance, continuity and diode test

O

O

Min/Max and average recording

O

O

Improved sleep mode for long battery life

O

O

Relative mode to remove test lead resistance
from low ohms measurements

O

O

Auto and manual ranging

O

O

CAT III 1000 V
CAT IV 600 V

CAT III 1000 V
CAT IV 600 V

Built-in thermometer

O

Safety rating

Specifications

True RMS
Fluke 28 II

Functions

Maximum

Voltage DC
Voltage AC
Current DC
Current AC
Temperature

On all inputs

1000 V
1000 V
10 A
10A

Max.
Resolution
0.1 mV
0.1 mV
0.1 μA
0.1 μA

27 II

28 II

±(0.1% + 1)
±(0.5% + 3)
±(0.2% + 4)
±(1.5% + 2)

Resistance
Low pass filter (Measurement on VSD’s)
Capacitance
Frequency
Peak transient capture

±(0.05% + 1)
±(0.7% + 4)
±(0.2% + 4)
±(1.0% + 2)
-200 ºC to
+1090 ºC
0.1 Ω to 50 MΩ
yes
1 nF to 9999 μF
0.5 Hz to 199.99 kHz
250 μS

Accuracies are best accuracies for each function

Battery Life: 3x AA alkaline, 800 hrs typical
Size (HxWxD): 198 x 100 x 63.5 mm

Weight: 0.75 kg
Lifetime Warranty

Included Accessories
TL 75 Test leads, AC 72 alligator clips, 80BK-A
temperature probe (28 II), holster, manual,
CD-ROM, three AA batteries (installed)

Recommended Accessories

Ordering Information
Fluke 27 II IP 67 Industrial Multimeter
Fluke 28 II IP 67 True-RMS Industrial Multimeter

PV 350
See page 113

i200
See page 114

i410
See page 115

80K-6
See page 121

21

88V Automotive Meter

The right meter for auto-electric diagnosis
Perhaps the most important tool you’ll
use in troubleshooting auto electrical
systems is the multimeter. Basic
multimeters measure voltage, current
and resistance, while automotive
multimeters like the Fluke 88V have
features that can check frequency, duty
cycle, make diode tests, and measure
temperature, pressure and vacuum.

Features
Continuity for detecting open and shorts

88V/A
O

Frequency for “pulsed-DC” and AC tests

O

Duty cycle to verify operation of feedback carburetors

O

Diode test for alternator testing

O

Built-in thermometer; thermocouple probe included

O

Min/Max/Average recording with Min/Max Alert

O

Peak capture to record transients as fast as 250 μs

O

Relative mode to remove test lead resistance from low ohms measurements

O

Millisecond pulse width measurements for fuel injectors

O

AutoHOLD® to capture stable readings

O

Large display with bright, two-level backlight

O

Magnet hanger to attach meter to the vehicle

O

RPM80 Inductive Pickup for both conventional and distributorless (DIS) ignitions

O

Fluke 88V/A

Hard Meter Case

O

Safety rating

CAT III 1000 V,
CAT IV 600 V

Specifications
On al inputs

Included Accessories
H80M Holster with TPAK Meter Hanging
Solution, TL224 SureGrip Silicone Test Lead
Set, TP220 SureGrip Test Probe Set, AC285
SureGrip Large Jaw Alligator Clip Set, 80BK
Integrated Temperature Probe, RPM80
Inductive Pick-up Probe, C800 Hard Case,
User’s Manual + Quick Reference Guide

Range
1000V
1000V (5 kHz)
10A
10A
50MΩ
10mF
200kHz
1090ºC

Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency
Temperature

Fluke 88V
Resolution
0.1mV
0.1mV
0.1μA
0.1μA
0.1Ω
0.01nF
0.01Hz
0.1ºC

Accuracy
0.1%
0.5%
0.4%
1.2%
0.4%
1%
0.005%
1%

Battery Life: 88V – Over 400 hours typical
Weight: 88V – 0.36 kg
(alkaline)
Lifetime Warranty
Size (HxWxD): 88V – 186 mm x 86 mm x 32 mm

Ordering Information
Fluke 88V/A Automotive Meter Combo Kit

Recommended Accessories

TL82
See page 113

22

TLK-282
See page 113

90i-610s
See page 113

80PK-27 (requires 80AK)
See page 116

PV350
See page 113

8845A/8846A
6.5 Digit Precision Multimeters
Precision and versatility for bench or
systems applications
The Fluke 8845A and 8846A, 6.5 digit
precision multimeters have the precision
and versatility to handle your most
demanding measurements on the bench
or in a system.

Fluke 8845A

Perform 4-wire measurements easily
with two leads: Patented split terminal
jacks for 2x4 Ohms function allows you
to perform precise 4-wire measurements
with only two leads instead of four.
Optional Kelvin leads accessories are
available to enable you to establish a 4wire connection even in tight spaces.
Systems Capabilities: Both instruments
include an RS-232, IEEE-488 and Ethernet
interface as standard, with popular
DMM emulation modes makes systems
integration a simple task.
Software: Transfer data points from your
meter to your PC with the free copy of
FlukeView Forms Basic. To customize
your forms upgrade with FVF-UG.

Dual Display offers versatile graphical
capabilities: The 8845A and 8846A
features a unique graphical display that
can reveal signal quality issues like drift,
intermittent and stability by viewing
the measurement data as a real time
TrendPlot™, Histogram or Statistics
using the unique analyze mode.
Wide Measurement Ranges: Resistance
or current has been extended to cover
the widest range possible.

Fluke 8846A

Features
8845A

Use the built-in TrendPlot paperless chart recorder to
graphically identify the extent of drift and intermittent
events in analog circuits

Display
Resolution
Measurement Rate (Rdgs/s)
Continuity / Diode Test
Analytical Functions
Math Functions
USB Device Port
Real Time Clock
Interfaces
Programming Languages/
Emulation Modes
Safety

View results in Histogram mode to reveal stability or
noise problems in analog circuits

8846A
Dual VFD Dot Matrix
6.5 Digits
1000
Yes
Statistics, Histogram, TrendPlot™, Limit Compare
NULL, Min/Max, dB/dBm
–
USB Memory Drive port
–
Yes
RS232, IEEE-488.2, Ethernet
SCPI (IEEE-488.2), Agilent 34401A, Fluke 45
Designed to comply with IEC 61010-12000-1, ANSI / ISA-S82.01-1994, CAN /
CSA-C22.2 No.1010.1-92 1000V CATI / 600V CATII

Specifications
(Check the Fluke web for detailed specifications)
8845A

Handle even the most demanding measurements with
high accuracy and 6.5 digit resolution

True RMS

Included Accessories
LCI Line Power Cord, TL71 Test Lead Set,
Spare Line Power fuse, Programmers Manual/
User Manual on CD-ROM, 884X-USB USB to
RS232 Cable Adapter, FVF-BASIC FlukeView
Forms Software Basic Version.

Function*
Voltage DC
Voltage AC (Freq 300 Hz)
Resistance (2x4 Wire)
Current DC
Current AC (Freq. 3Hz-10kHz)
Freq/Period
Capacitance
Temperature RTD

Resolution

Accuracy* (%)

Range

Resolution

Accuracy* (%)

1000 V
750 V
100 MΩ
10 A
10 A
300 kHz
-

100 nV
100 nV
100 μΩ
100 pA
10 μA
1 μHz
-

0.0035
0.06
0.01
0.05
0.10
0.01
-

1000 V
1000 V
1 GΩ
10 A
10 A
1 MHz
1 nF to 0.1 F
-200 to +600º

100 nV
100 nV
10 μΩ
100 pA
100 pA
1 μHz
1 pF
0.001º

0.0024
0.06
0.01
0.05
0.10
0.01
1
0.06

* Accuracy =+/- (% of reading)

Size (HxWxD): 88 mm x 215 mm x 293 mm
Weight: 3.6 kg
Three Year Warranty

Recommended Accessories

Ordering Information
Fluke 8845A
6.5 Digit Precision Multimeter
Fluke 8845A/SU 6.5 Digit Precision
Multimeter (software + cable)
Fluke 8846A
6.5 Digit Precision Multimeter
Fluke 8846A/SU 6.5 Digit Precision
Multimeter (software + cable)
Calibration & Service agreements

8846A

Range

884X-case
Hard case

TL2X4W-TWZ
2x4 Wire Ohms Tweezer
Test Leads

TL2X4W-PT II
2x4 Wire Ohms Test
lead 2mm Probe Tip

884X-512M
USB Memory 512M

FVF-UG
FlukeView Forms
Software Upgrade

23

8808A 5.5 Digit Multimeter
Versatile multimeter for manufacturing,
development and service applications

Fluke 8808A

Manufacturing test, R&D, development
and service applications demand
performance and flexibility from a
bench meter. The Fluke 8808A delivers a
wide variety of measurement functions,
including volts, ohms, and amps, plus
frequency - all at superior accuracy and
resolution with a basic V dc accuracy of
0.015 %.
Measure sensitive leakage current: The
Fluke 8808A includes two low impedance
low current ranges for measuring
sensitive leakage currents (i-Leakage).

The Fluke 8808A includes two low impedance low
current ranges for measuring sensitive leakage
currents

Use setup keys (S1-S6) for fast access to repetitive
measurements. Setups can include limit compare mode
with pass/fail indicators

Eliminate production mistakes: The
8808A has a limit compare mode with
built in display enunciators that clearly
show whether a test is within or out of
limits.
Perform 4-wire measurements with
only two leads: Patented split terminal
jacks for 2x4 Ohms function allow you
to perform precise 4-wire low ohms
measurements with only two leads
instead of four. Optional test lead
accessories are available to enable you
to establish a 4-wire connection even in
tight spaces or on surface mount devices.

Perform routine manufacturing
functional tests with consistency:
Use setup keys (S1 – S6) for fast access to
repetitive measurements. Operators no
longer need to press multiple buttons to
make routine measurements.

Features
8808A
VFD multi segment
5.5 digits
V ac, V dc, I dc, I ac, Ω, Cont, Diode
2X4 Wire Ohms, Freq, i-Leakage
Yes
Limit Compare
dBm, dB, Min, Max
RS-232, USB via optional adapter
Simplified ASCI, Fluke 45
CAT I 1000 V, CAT II 600 V

Display
Resolution
Measurements
Advanced Measurements
Continuity / Diode Test
Analytical Functions
Math Functions
Interfaces
Programming Languages/Modes
Safety Rating

Specifications
(Check the Fluke web for detailed specifications)
Functions
Voltage DC
Voltage AC
(Freq. 10 Hz to 100 kHz)
Resistance (2x4 Wire)

Dual Display

True RMS

Range
200 mV to 1000 V
200 mV to 750 V

1 μV
1 μV

Accuracy*
0.015
0.2

200 Ω to 100 MΩ

1 mΩ

0.02

Current DC

200 μA to 10 A

1 nA

0.02

Current AC
(Freq. 20 Hz to 2 kHz)
Freq. Period

20 mA to 10A

100 μA

0.3

20 Hz to 1 MHz
(Freq. only)

0.1 mHz

0.01

Included Accessories

* Accuracy = +/- (% of reading)

LCI Line Power Cord, TL71 Test Lead Set, Spare
Line Power fuse, 884X-USB USB to RS232 Cable
Adapter, FlukeView Forms Software Basic
Version, Programmers Manual/User Manual
on CD-ROM.

Size (HxWxD): 88 mm x 217 mm x 297 mm
Weight: 2.1 kg
Three year Warranty

Recommended Accessories

Ordering Information
Fluke 8808A
Fluke 8808A/SU
Fluke 8808A/TL

24

Resolution

5.5 digit multimeter
5.5 digit multimeter,
(software & cable)
5.5 digit multimeter,
2X4W Test Lead Kit
TL2X4W-TWZ
2x4 Wire Ohms Tweezer
Test Leads

884X-case
Hard case

TL2X4W-PT II
2x4 Wire Ohms Test
lead 2mm Probe Tip

884X-short
4-Wire Short

FVF-UG/SC4/SC5
FlukeView Forms
Software

Clamp Meters and
Electrical Testers
The ergonomic clamp meters feature wide opening jaws for safe, fast
non-contact current measurement. The Fluke leakage clamp meter is
ideal for non-invasive checks of insulation resistance.
The range of electrical testers includes two-pole testers for taking
quick measurements in tight spaces, phase rotation indicators to
take the guess work out of checking phase/motor rotation, a
multipurpose cable locator and handy voltage alerts.

25

330 Series/902 Clamp Meters
Expanded capabilities for current
measurement

Fluke 336

Fluke 335

The Fluke 330 Series Clamp Meters offer
all the features you need to fit the way
you work. The small body and jaws fit
perfectly in your hand and into tight
places. Meter controls are positioned so
that current measurements can be down
with one hand. A large backlit display (on
most models) is easy to see and a handy
Display Hold keeps measurements on the
display. Measuring starting current for
motors, lighting, etc. is easy with the inrush current function (on most models).

The Fluke 902 adds temperature and
capacitance measurement capabilities to
the line, ideal for heating, ventilation and
air conditioning system inspections.

Features
Functions
True-RMS
Display backlight
Auto shut-off
Display Hold
Motor start-up current
Low battery indication
Large jaw
Min/Max
Current AC/DC
Temperature

Fluke 334

Fluke 333

333

334

335
O
O
O
O
O
O

O
O
O
O
O

O
O
O

336
O
O
O
O
O
O
O
O

337
O
O
O
O
O
O
O
O
O

902
O
O
O
O
O
O
O*
O

* DC A: 0-200 μA direct measurement

Fluke 337

Specifications
Functions

Range

333

Current AC

0-400.0A

2% ± 5 counts

0-600.0A

334

335

336

2% ± 5 counts

2% ± 5 counts

2% ± 5 counts

0-999.9A
Crest Factor

337

902
1% ± 5 counts

2% ± 5 counts

0-600.0A

2.4 @ 500A

3 @ 500A

2.0 @ 600A

2.5 @ 600A

0-999.9A

2.4 @ 500A
2.0 @ 600A
3 @ 500A
2.5 @ 600A
1.42@ 1000A

Current DC

True RMS

Ordering Information
Fluke 333
Fluke 334
Fluke 335
Fluke 336
Fluke 337
Fluke 902

Clamp Meter
Clamp Meter
True-RMS Clamp Meter
True-RMS Clamp Meter
True-RMS Clamp Meter
True-RMS Clamp Meter
(HVAC)

1% ± 5 counts
2% ± 5 counts

0-999.9A
In-rush
Current

2% ± 5 counts

Integration
time

100mS

100mS

100mS

100mS

Voltage AC

0-600.0V

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

Voltage DC

0-600.0V

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

Resistance

0-600.0Ω

1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts

0-6000Ω

1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts

Included Accessories
C33 Soft case, TL75 test leads, 80BK Integrated
DMM temperature probe (902),
2 AA alkaline batteries, instruction card and
safety information sheet.

0-200 μA
0-600.0A

Fluke 902

0-9999Ω
Continuity
Frequency

1.5% ± 5 counts
≤ 30Ω

≤ 30Ω

≤ 30Ω

5-400Hz

≤ 30Ω

≤ 30Ω

0.5% ± 5 counts

Temperature

-10° to 400°C

1% ± 0.8°C

Capacitance

1μF to 1000μF

1.9% ± 2 counts

Battery Life: Alkaline, 150 hours
Size (HxWxD):
238 mm x 79 mm x 41mm (333, 334,
335 and 902)
251 mm x 79 mm x 41 mm (336 and 337)

Jaw Opening: 30 mm (333, 334, 335 and 902)
42 mm (336, 337)
Weight: 0.312 kg
Three Year Warranty

Recommended Accessories

H3
See page 119

26

≤ 30Ω

TL223
See page 110

L215
See page 111

320 Series Clamp Meters
Big features, small package
The Fluke 321 and 322 are designed
to verify the presence of load current,
ac voltage and continuity of circuits,
switches, fuses and contacts. These small
and rugged clamp meters are ideally
suited for current measurements up to
400 A in tight cable compartments.

Model 322 also offers DC voltage
measurements and has a higher
resolution for loads below 40 A.

Features
Functions
Compact design
Auto shut-off
Display Hold
Low battery indication
Current AC
Volts DC

321
O
O
O
O
O

322
O
O
O
O
O
O

Fluke 322

Specifications
321
Fluke 321

322

Functions
Current AC

Range
400.0A

Resolution
0.1A

Range
40.00A
400.0A

Resolution
0.01A
0.1A

Voltage AC

0-400.0V
400-600V

0.1V
1V

0-400.0Ω
≤ 30Ω

0.1Ω

0-400.0V
400-600V
0-400.0V
400-600V
0-400.0Ω
≤ 30Ω

0.1V
1V
0.1V
1V
0.1Ω

Voltage DC
Resistance
Continuity

Included Accessories
C23 Soft carrying case, TL75 test leads,
(2) AA alkaline batteries, coated instruction
card, safety information sheet.

Battery Life: 100 hours typical
(2 AAA carbon zinc)
Size (HxWxD): 190 mm x 63 mm x 35 mm
Jaw Opening: 25 mm

321
322
Best Accuracy
1.8% ± 5 counts 1.8% ± 5 counts
(50 - 60Hz)
(50 -60Hz)
3.0% ± 5 counts 3.0% ± 5 counts
(60Hz - 400Hz) (60Hz - 400Hz)
1.2% ± 5 counts 1.2% ± 5 counts
(50-400Hz)
(50-400Hz)
1% ± 5 counts
1% ± 5 counts

1% ± 5 counts

Weight: 0.23 kg
Two Year Warranty

Combo Kit
Ordering Information
Fluke 321
Fluke 322
Fluke 117/322 Kit
Fluke 62/322/1AC

Clamp Meter
Clamp Meter
Electricians Combo Kit
IR Thermometer, Clamp
Meter and Voltage
Detector Kit

Fluke 62/322/1AC Kit

Fluke 117/322 Kit

• Fluke 62 Infrared
Thermometer
• Fluke 322 Clamp Meter
• Fluke 1AC II Volt Alert

See page 4

Recommended Accessories

H3
See page 119

TL223
See page 110

L215
See page 111

27

350 Series AC/DC Clamp Meters
True-RMS, 2000 A Clamp Meters
for industrial and utility applications
Confidently take reliable readings with
the true-rms, Fluke 353/355 Clamp
Meters; the tools of choice for high
current measurement up to 2000 A. The
extra-wide jaw easily clamps around
large conductors, typically found in high
current applications. The rugged design
and CAT IV 600 V,
CAT III 1000 V ratings add an extra
element of protection when taking
high-powered measurements.

Accurate peak measurements can be
taken using the in-rush current mode ideal for motors and inductive loads. The
355 also measures voltage and resistance,
making this the most versatile tool
for utilities, electrical contractors and
industrial service technicians.

Features
True-RMS measurements
Display backlight
Motor start-up current
Min/Max/Average
Voltage AC/DC
Resistance measurement
Continuity measurement with beeper

Fluke 353

353

355

O
O
O
O

O
O
O
O
O
O
O

Specifications
(Check the Fluke web for detailed specifications)
Fluke 355

Functions
Current AC/DC

Crest Factor
Voltage AC/DC

Resistance

Continuity beeper
Frequency
True RMS

Range
0-40.00 A
0-400.0 A
0-2000 A; 1400 AC rms

353
1.5% ± 15 counts

355
1.5% ± 15 counts

1.5% ± 5 counts

1.5% ± 5 counts

2.4

2.4
1% ± 10 counts

0-4.000 V
0-40.00 V
0-400.0 V
0-600 V AC rms
0-1000 V DC
0-400.0 Ω
0-4.000 kΩ
0-40.00 kΩ
0-400.0 kΩ
Appr. ≤ 30 Ω
5.0Hz to 100.0Hz
100.1Hz to 999Hz

1% ± 5 counts

1.5% ± 5 counts

0.2% ± 2 counts
0.5% ± 5 counts

Included Accessories
Fluke 353: C43 Soft Meter Case, 6 AA batteries,
users manual
Fluke 355: C43 Soft Meter Case, 6 AA batteries,
TL224 SureGrip® Silicone Test Lead Set, TP2
Slim Reach Test Probe Set (2 mm), AC285
SureGrip® Alligator Clip Set, users manual

Power Supply:
Battery Life:

6 x 1.5V AA NEDA 15A
or IEC LR6
100 hours (with typical
usage, backlight off)

Size (HxWxD): 300 mm x 98 mm x 52 mm
Jaw opening: 58 mm
Weight: 0.814 kg
Two year warranty

Ordering information
Fluke 353
Fluke 355

AC/DC Clamp Meter
AC/DC Clamp Meter

Recommended Accessories

TL223 (Fluke 355)
See page 110

28

L215 (Fluke 355)
See page 111

360 Leakage Clamp Meter
Leakage current measurements with a tough,
pocket sized clamp meter
The Fluke 360 is ideal for non-invasive
checks of insulation resistance.
The unique jaw design eliminates the
influence of adjacent current conductors.
The ergonomic design of the Fluke 360
ensures easy measuring. The measuring
clamp fits into tight spaces and the
wide display angle clearly shows the
measurement result. The data hold
button keeps the measured value on the
display after removing the clamp for the
measured conductor.
The light Fluke 360 offers the widest
range of current measurement for
maintenance professionals and
contractors.

Features
• Measurement of leakage protectives
conductor and touch current with a
resolution of 1μA
• Advanced shielding to ensure accurate
results when measuring near other
conductors
• Automatic ranging within the manually
selected mA or A range
• Easily viewed measurements on digital
and bargraph display and HOLD when
measuring in hard to see locations
• Broad range of measurements currents
up to 60 A for all installation needs
• Easy carrying, pocket sized clamp with
wide 40 mm jaw size
• Display-Hold for convenience in use
• Auto power off with audible warning
buzzer
• Conformance to IEC61010 and EMC
standard
• Meets all the applications and
performance classes in safety standard
VDE0404-4 and the new VDE0702

Fluke 360

Specifications
(Check the Fluke web for detailed specifications)
Functions

Range
3mA
30mA
30A
60A
50 and 60Hz

Current AC

Frequency

Resolution
0.001A
0.01mA
0.01A
0.1A

Accuracy
1% ± 5 counts
1% ± 5 counts (0~50A)
5% ± 5 counts (50~60A)

Battery type: 3 Volt Lithium, 90 hours typical
Size (HxWxD): 176 mm x 70mm x 25 mm
Weight: 0.2kg
One Year warranty

Included accessories
Soft carrying pouch and users manual

display: 1.7mA

Ordering information
Fluke 360

leakage
current 0.5mA

Leakage Clamp Meter

ground

leakage current
1.2mA (e.g. via
motor shaft)

29

T100 Series
Voltage and Continuity Testers
The fast and easy solution to voltage,
continuity and phase rotation testing
The fast and easy solution to voltage,
continuity and resistance measurements.
Ideal for site conditions, the 3 models
of the T100 Series 2-pole testers have a
rugged construction and ergonomically
formed housing for perfect handling.
All models offer a patented three-phase
rotation detection system providing
quick phase rotation indication.

Moreover they have a special electrical
torch function for working in low light
level environments and have an ingress
protection rating of IP65. The T100 Series
are compliant with EN 61010-1 and
EN61243-3 requirements.

Fluke T120

Features
T100

Fluke T140

Fluke T100

Display
Led Bargraph
Backlight
Resistance measurement
Switchable load
Voltage test
Optical and acoustical continuity test
Rotary field indication
Single pole test for phase detection
Indication of polarity
Electrical torch function
Probe tip protection
The voltage display also functions when using
discharged - or o batteries

12 LED’s

T120
LCD
12 LED’s

O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O

T140
LCD
12 LED’s
O
O
O
O
O
O
O
O
O
O
O

Specifications

Included Accessories
Two 1.5V batteries and instruction sheet

Voltage AC/DC
Continuity
Frequency
Phase rotation
Resistance measurement
Response time

T100
12 - 690 V
0 - 400 kΩ
0 - 400 Hz
100 to 690 V
< 0.1 s

T120
12 - 690 V
0 - 400 kΩ
0 - 400 Hz
100 to 690 V
< 0.1 s

T140
12 - 690 V
0 - 400 kΩ
0 - 400 Hz
100 to 690 V
Up to 1999 Ω
< 0.1 s

Ordering Information
Fluke T100
Fluke T120
Fluke T140

Voltage/Continuity Tester
Voltage/Continuity Tester
Voltage/Continuity Tester

Size (HxWxD): 240 mm x 56 mm x 24 mm
Case: IP65 (water-jet and dust tight protection)
Weight: 180 g
Two year warranty

UK versions are compliant with GS38

Recommended Accessories

C33 (T100 Series)
See page 118

30

T5 Electrical Testers
The fast and easy solution to basic
electrical testing
The Fluke T5 testers let you check
voltage, continuity and current with
one compact tool. Select volts, ohms or
current and the instrument does the rest.
Model T5-600 measures 600 volts
AC/DC, model T5-1000 is designed for
1000 volts. OpenJaw™ current technology
lets you check current up to 100 A,
without breaking the circuit. The optional
H5 holster keeps the test probes and
leads ready to test and lets you clip the
T5 onto your belt.

Features and Specifications

Fluke T5-1000

Fluke T5-600

T5-600
1000
O
O
O
600 V
600 V
100 A
1000 Ω
600V CAT III

Display Count
Automatic Selection
Continuity and Bleeper
Sleep Mode
AC Voltage
DC Voltage
AC Current
Resistance
Safety range

Battery life: 400 hours
Size (HxWxD):
203 mm x 51 mm x 30.5 mm

Fluke T5-H5-1AC Kit

Fluke T5-600/62/1ACII Kit

T5-1000
1000
O
O
O
1000 V
1000 V
100 A
1000 Ω
1000 V CAT III / 600 V CAT IV

Weight: 0.38 kg
Two year warranty

Fluke T5-H5-1AC Kit

Fluke T5-600/62/1AC Kit

The ideal kit for busy electrical
contractors and electricians. The benefits
of a voltage and current meter and noncontact voltage detector all in one kit. A
holster for the T5 is also included.

This kit is designed to help electricians
and HVAC technicians solve problems
quicker. Test first for overheated electrical
devices using an IR thermometer; then
use elecrtrical test tools to find out more
about the problem.

Kit includes:
- Fluke T5-1000
- H5 holster
- Free Fluke 1AC-II

Kit includes:
• Fluke T5-600
• Fluke 62
• Fluke 1AC II
• C115

Included Accessories
TP4 4 mm detachable probes (detachable GS38
probes for the UK) and instruction sheet

Ordering Information
Fluke T5-600
Fluke T5-1000
Fluke T5-H5-1AC Kit
Fluke T5-600/62/1AC

Electrical Tester
Electrical Tester
Electrical Tester with
holster and IAC
Electrical Tester,
IR Thermometer,
Voltage Detector Kit

Recommended Accessories

H5
See page 119

ACC-T5-Kit
See page 111

AC285
See page 112

31

1AC II Volt Alert
LVD1/LVD2 Volt Lights
SM100/200/300 SocketMaster-testers

Fluke 1AC II VoltAlert™

Fluke 1AC II

The Fluke VoltAlert AC voltage detector is
very easy to use – just touch the tip to a
terminal strip, outlet or cord. When the tip
glows red and the unit beeps, you know
there is voltage on the line.
• It continually tests its battery and its
circuit integrity with a periodic double
flash visual indication.
• Highest safety rating: CAT IV 1000 V
• Detects voltage without metallic contact

Operating range: 200 – 1000 V AC
Batteries: Two AAA Alkaline
Size (H): 148 mm
Two Year Warranty

Fluke 1AC II VoltAlert™ 5-pack
• Buy 4 get 1 FREE

LVD1 Volt Light
Dual sensitivity voltage detector
• Detects voltage from 40 V to 300 V AC
• Blue light means you’re close
• Red light means you’re at the source
• Comes with a versatile clip to secure light to
pocket, hat or even panel door
LVD1

LVD2 Volt Light

LVD2

Combines bright light and voltage detection in one pen style design
• Dual sensitivity
• Detects voltage from 90 V to 600 V AC
• Blue light means you’re close
• Red light means you’re at the source
• Rated to CAT IV 600 V

SM100/200/300 SocketMaster Testers
The fast way to check if your sockets are safe.

Ordering Information
Fluke 1AC II
Fluke 1AC II 5PK
LVD1
LVD2
SM100
SM200
SM300

VoltAlert
VoltAlert (5-pack)
Volt Light
Volt Light
SocketMaster Tester
SocketMaster Tester
SocketMaster Tester

SM100

SM200

SM300

Only available with UK plug
Features
Clear indication of wiring status
Audible notification of wiring status
Unique soft-touch RCD test checks 30 mA RCD´s for trip
within 300 ms
Earth Volts Touchpad detects raised earth voltages >50 V,
indicating potentially dangerous situations

32

SM100
O

SM200
O
O

SM300
O
O
O
O

9040/9062
Phase Rotation Indicators
Take the guess work out of phase/motor
rotation measurements
Fluke 9040

Fluke 9062

The Fluke 9040 is effective for measuring
phase rotation in all areas where
three-phase supplies are used to feed
motors, drives and electrical systems.
The Fluke 9040 is a rotary field indicator
and can provide clear indication of the
3 phase via an LCD display and the
phase rotation direction to determine
correct connections. It allows rapid
determination of phase sequence
and has a voltage (up to 700 V) and
frequency range suitable for commercial
and industrial applications. Test probes
supplied with the instrument have a
variable clamping range for safe contact,
especially in industrial sockets.

The unique Fluke 9062 provides rotary
field and motor rotation indication with
the benefits of contact-less detection.
Purpose made for commercial and
industrial environments, the Fluke 9062
provides rapid indication of 3 phase
rotation using test leads supplied or can
be used to determine motor rotation on
synchronous and asynchronous 3 phase
motors. The contact-less detection is
ideal for use on motors where the shaft is
not visible.
Test probes supplied with the instrument
have a variable clamping range for safe
contact, especially in industrial sockets.

Fluke 9040

Features
9040
Via LCD
O

3 phase indication
Indication of phase rotation
Indication of motor rotation direction
Contact free determination of the rotation direction of running motors
Clear LCD display
No battery required

9062
Via LED
O
O
O

O
O

Fluke 9062

9040:

Specifications

9062:

Voltage range
Phase display
Frequency range
Operating time

Size (HxWxD) Fluke 9040:
124 mm x 61 mm x 27 mm
Size (HxWxD) Fluke 9062:
124 mm x 61 mm x 27 mm

9040
40 - 700 V
15 - 400 Hz
Continuous

9062
Up to 400 V
120 - 400 V AC
2-400 Hz
Continuous

Power supply 9040: from unit under test
Power supply 9062: 1 x 9V
Weight 9040: 0.20 kg
Weight 9062: 0.15 kg
Two Year Warranty

Fluke 9062 Applications

Included Accessories
Fluke 9040: Alligator clips - black (3)
Flexible test probes - black (3)
Fluke 9062: Alligator clips - black (3)
Flexible test probes - black (3)
Test leads - black (3)

Ordering Information
Fluke 9040
Fluke 9062

Phase Rotation Indicator
Motor and Phase Rotation
Indicator

Determine the presence of
phase sequence of multiphase
electrical supplies.

Determine the rotation of
running motors simply by
placing the instrument on
the motor casing.

Check the correct rotation of
motors prior to connection.

Recommended Accessories

TLK290
See page 111

TLK291
See page 111

C25
See page 118

33

2042 Cable Locator
The multipurpose solution to cable location
The Fluke 2042 is a professional general
purpose cable locator. It is ideal for
tracing cables in walls and underground,
locating fuses/breakers on final circuits
and locating interruptions and shortcircuits in cables and electrical floor
heating systems.
It can also be used for tracing metallic
water and heating pipes. The unit is
supplied as a complete kit comprising of
a transmitter and receiver in a purposemade carry case. The receiver also
incorporates a torch function for working
in dimly lit locations.

Transmitter

Receiver

Fluke 2042

• Receiver with a backlight LCD-display
for level of receiving signal, code
of receiving signal and live voltage
indication
• Automatic or manual adjustment of
receiving signal sensitivity
• Switchable acoustic receiving signal
• Auto-Power-Off
• Additional torch lamp function for
working in dark environments
• Additional transmitters are available
for extension or to distinguish between
several signals.

• For all applications (live or dead cables)
without additional instruments
• Set includes a transmitter and a
receiver
• Proven digitally coded sender signal
guarantees clear signal identification
• Transmitter with LCD-display for
transmitting level, transmitting code
and external voltage

Specifications

Transmitter
12V, 50V,120V, 230V, 400V
0..60 Hz
125 kHz
Up to 400V AC/DC

Voltage Measurement Range
Frequency Range
Output signal
Voltage
Tracing depth cable location

Receiver

0...2.5m wall/underground
cables
0...0.4m

Main voltage detection

Batteries Transmitter: 6 pc Batteries 1.5V
Batteries Receiver: 1 pc Battery 9V
Size (HxWxD) Transmitter:
190 mm x 85 mm x 50 mm
Size (HxWxD) Receiver:
250 mm x 65 mm x 45mm
Weight Locator: 0.45 kg
Weight Receiver: 0.36 kg
Two Year Warranty

Fluke 2042 applications

Included Accessories
TL27 Heavy Duty Test Lead Set (2)
TP74 Lantern Tip Test Probe Set
AC285 Alligator Clip Set
Soft carrying case
Hard case

Ordering Information
Fluke 2042
Fluke 2042T

Cable Locator
(transmitter + receiver)
Cable Locator Transmitter

Location of fuses/breakers
and assignment to circuits

Tracing of underground
cables (max. depth 2.5 m)

Precise location of cable
interruptions with additional
transmitter

Recommended Accessories

Fluke 2042T

34

Insulation Testers and
Earth Ground Testers
With a 5000 V MegOhmMeter for industrial-strength insulation testing
and a range of compact hand-held instruments, we offer a solution
for every troubleshooting and preventive maintenance application.
Two of the digital hand-held insulation testers also include full-featured
multimeters.
The Fluke Earth Ground Testers can perform all four types of earth
ground measurement, including stakeless testing with earth ground
loop resistances using only clamps.

35

Insulation Tester
Selection Guide

InstallationTest Functionality
Test voltages
Insulation Resistance Test Range
Polarization Index/Dielectric Absorption Ratio
Auto Discharge
Time Ramp test (Breakdown)
Pass/Fail Comparison
Estimated Number of
Insulation resistance Tests
Voltage > 30V Warning
Memory
Remote Test Probe
Lo Ohms
Display
Continuity

Multimeter Functionality
AC/DC Volts
Current
Resistance
Temperature (contact)
Lo-Pass Filter
Capacitance
Diode Test
Frequency
MIN/MAX
Other
Hold/Lock
Backlight

1577

1587

1587T

1503

1507

1550B

500V, 1000V
0.1MΩ - 600MΩ

50V, 100V, 250V, 500V,
1000V
0.01 MΩ - 2GΩ

50V, 100V

500V, 1000V

0.01MΩ - 100MΩ

0.1MΩ - 2GΩ
O

50V, 100V, 250V, 500V,
1000V
0.01MΩ - 10GΩ
O
O

250V, 500V, 1000V,
2500V, 5000V
200KΩ - 1TΩ
O
O
O

O

O

O

1000

1000

1000

1000

O
1000

O

O

O

O

O

O

O

O

Digital LCD

Digital LCD

Digital LCD

O
O
Digital LCD

O
O
Digital LCD

O

O

O

(200mA)

(200mA)

O
O
O

O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O

O

O

O

O

O

O

O
O

O
O

O
O

Battery

3
4 AA (NEDA 15A or
IEC LR6)

3
4 AA (NEDA 15A or
IEC LR6)

3
4 AA (NEDA 15A or
IEC LR6)

Digital LCD / Analog
Bar Graph

O

O
O

O
O

Software
Warranty (in years)

O
(99 locations)

1
4 AA (NEDA 15A or
IEC LR6)

1
4 AA (NEDA 15A or
IEC LR6)

O
(Fluke View® Forms
Basic)
2
Rechargeable

Buy a Fluke 1587 Combo Kit and save
Fluke 1587/ET Advanced Electrical
Troubleshooting Kit

Fluke 1587/MDT Advanced Motor
& Drive Troubleshooting Kit

This kit contains:
• Fluke 1587 Insulation Multimeter
• Fluke 62 Mini Infrared Thermometer
• i400 Current Clamp

This kit contains:
• Fluke 1587 Insulation Multimeter
• Fluke 9040 Phase Rotation Indicator
• i400 Current Clamp

Perform insulation tests with the Fluke
1587 plus a wide-range of DMM tasks with
confidence and ease. Use the i400 with your
Fluke 1587 to accurately measure AC current
without breaking the circuit. Check for hot
spots and measure temperature with the
Fluke 62 Mini non-contact thermometer.

Perform insulation tests with the Fluke
1587 plus a wide-range of DMM tasks with
confidence and ease. Use the i400 with your
Fluke 1587 to accurately measure AC current
without breaking the circuit. Check the phaserotation of three-phase motors easily and
safely with the Fluke 9040.

Fluke 1587/ET

36

Fluke 1587/MDT

1503/1507 Insulation Testers
Truly portable insulation resistance testers
When you need a low cost solution to
general purpose insulation testing look
no further than the new Fluke insulation
tester range. The Fluke 1507 and 1503
Insulation Testers are compact, rugged,
reliable and easy to use.

The multiple test voltages on both
models make them ideal for many
troubleshooting, commissioning and
preventive maintenance applications.
Additional features like the remote
probe save both time and money when
performing tests.

Features
1503
O

User selectable test voltages for many applications
Additional test voltages 50V, 100V, 250V
Special remote control probe for easy and safe measurements
Auto-discharge of capacitive voltage for added user protection
Live circuit detection prevents insulation test if voltage > 30 V
is detected for added user protection
Save both time and money with Automatic calculation of
Polarization Index and Dielectric Absorption Ratio
Auto Power off to save batteries
Large display with backlight
Continuity function (200 mA)
Compare function (pass/fail) for fast repetitive tests

Fluke 1503

O
O
O

1507
O
O
O
O
O
O

O
O
O

O
O
O
O

Fluke 1507

Specifications
Insulation specifications
Insulation test range
Test voltages
Test voltage accuracy
Insulation test current
AC/DC Voltage measurement
Resistance measurement range
Auto discharge

1503
0.1 MΩ to 2 GΩ
500 V, 1000 V
+ 20 %, - 0 %
1mA nominal
600 V (0.1 V resolution)
0.01 Ω to 20 kΩ
Discharge time < 0.5 second
for C = 1 μF or less
Up to 1 μF
> 4V ,< 8V
> 200 mA

Maximum capacitive load
Open circuit test voltage
Short circuit current

Battery life: Insulation Test: > 1000 tests
Size (HxWxD):
203 mm x 100 mm x 50 mm

Weight: 0.55 kg
One Year Warranty

Fluke 1503/1507 Applications

Included Accessories
TP165x
TL224
TP74

1507
0.01 MΩ to 10 GΩ
50 V, 100 V, 250 V, 500 V, 1000 V
+ 20 %, - 0 %
1mA nominal
600 V (0.1 V resolution)
0.01 Ω to 20 kΩ
Discharge time < 0.5 second
for C = 1 μF or less
Up to 1 μF
> 4V ,< 8V
> 200 mA

Remote Test Probe
SureGrip Silicone Test Lead Set
Lantern Tip Test Probe Set
Alligator clips

Ordering Information
Fluke 1503
Fluke 1507

Insulation Tester
Insulation Tester

Insulation test at a
distribution panel

Wiring test in a small
distribution box –
all in one spot

Recommended Accessories

C101
See page 119

38

PAK
See page 120

TLK 225
See page 111

AC285
See page 110

L210
See page 121

1577/1587
Insulation Multimeters
Two powerful tools in one
The Fluke 1587 and 1577 Insulation
Multimeters combine a digital insulation
tester with a full-featured True RMS
digital multimeter in a single compact,
handheld unit, which provides maximum
versatility for both troubleshooting and
preventive maintenance.

Whether you work on motors, generators,
cables, or switch-gear, the
Fluke 1587/1577 Insulation Multimeters
are ideally suited to help you with your
tasks.
The Fluke 1587T is specially designed for
the telecom environment.

Features
Multimeter Features
True RMS Voltage and Current for accurate measurements
Digital display counts
Autorange and manual range for easy testing.
Selectable filter for accurate voltage and frequency measurements on motor
drives
Min Max Recording, Diode test, temperature, capacitance & frequency
measurement for maximum flexibility.

Fluke 1577

1577
O
6000
O

Insulation features
User selectable test voltages for many applications
Additional test voltages 50V, 100V, 250V
Special remote control probe for easy and safe measurements
Auto-discharge of capacitive voltage for added user protection
Live circuit detection prevents insulation test if voltage > 30V is detected for
added user protection

Fluke 1587
Fluke 1587T

General features
Auto Power off to save batteries
Large display with backlight
Input Alert to warn for incorrect connections
Continuity

1587
O
6000
O
O

1587T
O
6000
O
O

O

O

O
O
O

O
O
O
O
O

O
O
O

O
O
O
O

O
O
O
O

O
O
O
O

O

Insulation Specifications
Functions
Measurement range
Test voltages

1577
0.1MΩ to 600MΩ
500V, 1000V

Test voltage accuracy
Insulation test current
Auto discharge

+ 20%, -0%
1mA nominal
Discharge time < 0.5s
for C = 1 μF or less
Up to 1 μF load

Maximum capacitive load

1587
0.01MΩ to 2GΩ
50V, 100V, 250V, 500V,
1000V
+ 20%, -0%
1 mA nominal
Discharge time <0.5s
for C = 1 μF or less
Up to 1 μF load

1587T
0.01MΩ to 100MΩ
50V, 100V
+ 20%, -0 %
1 mA nominal
Discharge time <0.5s
for C = 1 μF or less
Up to 1 μF load

Multimeter Specifications

Included Accessories
C101 Rugged, utility hard case
TL224 SureGrip Silicone Test Lead Set
AC285 SureGrip Alligator Clip Set
80BK Integrated DMM Temperature Probe
(Type K)
TP165X Remote Test Probe

Functions
Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency
Temperature

Battery life:

Maximum
1000V
1000V
400mA
400mA
50.0MΩ
9999μF
99.99kHz
-40°C to +537°C

Max. resolution
1 mV
0.1mV
0.01mA
0.01mA
0.1Ω
1 nF
0.01 Hz
0.1°C

Meter: 1000 hrs,
Insulation Test: >1000 tests

1577
± (0.2% + 2)
± (2% + 3)
± (1.0% + 2)
± (2% + 2)
± (1.2% + 2)
-

1587/1587T
± (0.09% + 2)
± (2% + 3)
± (0.2% + 2)
± (1.5% + 2)
± (0.9% + 2)
± (1.2% + 2)
± (0.1% + 1)
± (1% + 10)

Weight: 0.55 kg
Three Year Warranty

Size (HxWxD):
203 mm x 100 mm x 50 mm

Recommended Accessories

Ordering Information
Fluke 1577
Fluke 1587
Fluke 1587T

Insulation Multimeter
Insulation Multimeter
Insulation Multimeter
(for Telecom)

C25
See page 118

i400
See page 114

TPAK
See page 120

L215
See page 111

TL238
See page 110

37

1550B MegOhmMeter
Digital insulation testing up to 5000 Volts
The Fluke 1550B is a digital insulation
tester capable of testing switchgear,
motors, generators and cables at up to
5000 V DC. It can be used for a wide range
of tests: from simple spot checks to timed
tests and breakdown tests. Measurement
storage and PC interface software make it
ideal for preventive maintenance.
• Test voltages of 250 V, 500 V, 1000 V,
2500 V, 5000 V
• Capable of testing in 50 V increments
between 250 V and 1000 V, and 100 V
increments between 1000 V and 5000 V
• Measures 0 to 1 Tera-Ohm
• Warning voltage function alerts the
user that line voltage is present and
gives the voltage reading up to 600 V
AC or DC

• Guard system eliminates the effect
of surface leakage current on highresistance measurements
• Large digital/analog LCD shows detailed
measurement data
• Cable or insulation capacitance
• Leakage current
• Ramp function (0-5000 V DC) for
breakdown testing
• Timer 1 to 99 minutes
• Polarization index and dielectric
absorption calculated automatically
• 99 memory locations store all
measurements parameters
• Includes Quicklink 1550B Software and
Optical Interface cable

Fluke 1550B

Specifications
Test Voltage (DC)
250V
500V
1000V
2500V
5000V
Short circuit current
Bar graph range
Insulation test voltage accuracy
Induced AC mains current rejection
Charging rate for capacitive load

Leakage current
Capacitance measurements
Live circuit indicator
Timer increments; indicated to within 1 second
Ramp

Range
200kΩ to 5GΩ
5GΩ to 50GΩ
200kΩ to 10GΩ
10GΩ to 100GΩ
200kΩ to 20GΩ
20GΩ to 200GΩ
200kΩ to 50GΩ
50GΩ to 500GΩ
200kΩ to 100GΩ
100GΩ to 1TΩ
greater than 1 mA and less than
2mA
0 to 1TΩ
0% to + 10% at 1mA load current
2 mA maximum
5 seconds per μF

1nA to 2mA
0.01μF to 15.00μF
30V to 600V AC/DC, 50/60Hz
1 to 99 minutes; settable in
1 minute
0% to 100% of selected test
voltage, or until breakdown.

Accuracy (+/- reading)
5%
20%
5%
20%
5%
20%
5%
20%
5%
20%

± (5% + 2nA)
± (15% rdg + 0.03μF)
± (5% + 2V)

Included Accessories
Test leads, 5000 V-rated probes, Alligator clips,
Interface cable
Flukeview Forms Basic, soft carrying case with
water-proof bottom, instruction manual

Ordering Information
Fluke 1550B

MegOhmMeter

Operating Temperature: -20°C to 50°C
Storage Temperature: -20°C to 65°C
Relative humidity: 80% at 31°C,
50% at 50°C
Dust/water resistance: IP40
Operating Altitude: 0 to 2,000 mtrs.

Batteries: 12 volt, lead-acid, rechargeable
Size (HxWxD): 170 mm x 242 mm x 330 mm
Weight: 4 kg (with battery)
Two Year Warranty

FVF-SC2
See page 120

39

1620 Series
Earth Ground Testers GEO
Advanced technology for all your earth
ground testing applications

Fluke 1623

The new Fluke 1620 Series Earth Ground
Testers not only measure ground
resistance using the classic ‘fall of
potential test’ but also enable time
saving testing using the ‘selective’ and
‘stakeless’ methods. ‘Selective’ testing
does not require the electrode under
test to be disconnected during the
measurement, thus increasing safety.
The simple ‘stakeless’ method quickly
checks ground connections using two
current transformers (probes) clamped
around the ground conductor under test.
Offering ‘one-button’ simplicity, the 1623
is an all-in-one earth ground tester, while
the 1625 has extra versatility for more
demanding applications.

Earth ground resistance and soil
resistivity should be measured
when:
• Designing earth ground systems
• Installing new ground system and
electrical equipment
• Periodically testing ground and
lightning protection systems
• Installing large electrical equipment
such as transformers, switchgears,
machines, etc.

Features

Fluke 1625

1623
O
O
O
O

One-button measurement concept
3- and 4-pole earth ground measurement
4-Pole soil resistivity testing
2-Pole resistance measurement AC
2-and 4-pole resistance measurement DC
Selective testing, no disconnection of ground conductor (1 clamp)
Stakeless testing, quick ground loop testing (2 clamps)
Measuring frequency 128 Hz
Earth impedance measurement at 55 Hz
Automatic frequency control (AFC) (94 – 128 Hz)
Measuring voltage switchable 20/48V
Programmable limits, settings
Continuity with buzzer
Dust/water resistance
Safety rating

1625
O
O
O
O
O
O

O
O
O

IP56
CAT II 300 V

O
O
O
O
O
IP56
CAT II 300 V

Specifications
(Check the Fluke web for detailed specifications)
Fluke 1625 kit

Included accessories
Fluke 1623: Protective holster, 2 test leads,
2 alligator clips, users manual
Fluke 1623 Kit: same as above plus stake/reel
Set 4 pole and selective/stakeless clamp set
Fluke 1625: Protective holster, 2 test leads,
2 alligator clips, users manual
Fluke 1625 Kit: same as above plus stake/reel
set 4 pole and selective/stakeless clamp set

Fluke 1623 Kit
Fluke 1625
Fluke 1625 Kit
40

Basic GEO Earth Ground
Tester
Basic GEO Earth Ground
Tester Kit
Advanced GEO Earth
Ground Tester
Advanced GEO Earth
Ground Tester Kit

1625
0 to 300 kΩ
± 5%
20 / 48 V
250 mA

Battery type: 6 x AA alkaline cells
Size (HxWxD): 110 mm x 180 mm x 240 mm
Weight – 1623 Geo: 1.1 kg (including batteries)
1625 Geo: 1.1 kg (including batteries)
Two Year Warranty

Recommended Accessories

Ordering information
Fluke 1623

1623
0 to 20 kΩ
± 5%
48 V
> 50mA

Resistance ranges
Operating error
Test voltage
Short circuit current

EI-1623
EI-1625
Selective/stakeless clamp Selective/stakeless clamp
set for 1623
set for 1625

ES-162P3
Stake/reel set for 3 pole
measurements

ES-162P4
Stake/reel set for 4 pole
measurements

EI-162BN
320mm Split core
transformer for selective
measurements on high
voltage pylons

1621 Earth Ground Tester
Handheld earth ground testing
for mobile use
The Fluke 1621 is an easy-to-use
earth ground tester. The first line of
defense in detecting reliable ground
connections, the unit features basic
ground testing methods including 3-pole
Fall-of-Potential as well as 2-pole ground
resistance. Its convenient size, rugged
holster, and large, clear LCD display make
it an ideal field earth tester, for most
work environments. With a simple user
interface and intuitive functionality, the
Fluke 1621 is a handy tool for electrical
contractors, utility test engineers, and
earth ground specialists.

Features
• 3-pole Fall-of-Potential earth testing for
basic measurements
• 2-pole resistance measurements for
added versatility
• Easily capture values with single-button
operation
• Ensure accurate measurements with
automatic ‘noise’ voltage detection
• Hazardous voltage warning offers
increased user protection
• Clearly read and record data with a
large, backlit display
• Rugged holster and design for tough
work environments
• Portable size allows for easy
transportation
• Instantly be alerted to measurements
outside of your set limit, when you use
the adjustable limit setting
• Safety rating CAT II 600 V

Fluke 1621

Specifications
(Check the Fluke web for detailed specifications)
1621
0.15 Ω to 2 kΩ
± 6% of measured value + 5D
± 18% of measured value +5D
23 to 24 V AC
> 50 mA AC

Resistance range
Basic accuracy
Operating error according EN61557
Test voltage
Short circuit current

Battery type: 1 x 9 V alkaline (LR61)
Size (HxWxD): 216 mm x 113 mm x 54 mm
Weight: 0.850 kg
Two Year Warranty

Recommended Accessories
Included accessories
Two measuring leads with alligator clips 2 m, protective holster, users manual, CD-ROM

Ordering information
Fluke 1621

Earth Ground Tester
GEO CABLE-REEL 25M
Ground Earth Cable Reel
25 M Wire

GEO CABLE-REEL 50M
Ground Earth Cable Reel
50 M Wire

GEO EARTH STAKE
Ground Earth Stake

ES-162P3
Stake/reel set for 3 pole
measurements

41

1630 Earth Ground
Clamp Meter
Fast and easy earth ground loop testing
The Fluke 1630 earth ground clamp
meter simplifies ground loop testing and
enables non-intrusive leakage current
measurement. The ground loop testing is
also known as “stakeless” earth ground
testing. To carry out the measurement
there is no need for placing earth stakes
and disconnecting the earth system
from the electrical installation. The Fluke
1630 combines the two current clamps
needed to perform the stakeless ground
loop test in one compact and easy to use
instrument.
• Ground loop resistance testing without
any disconnection or additional earth
stakes
• Earth ground leakage current
measurement for system
troubleshooting
• True RMS AC current measurement
range up to 30 A

• Rapid evaluation of continuity without
disconnection and audible HI/LO alarm
• Display-HOLD function to freeze
measurements
• Recording function for automatic
storage of measured values, which can
be recalled later on the LCD display
• Automatic self calibration ensures
correct measurement every time
The Fluke 1630 is ideally suited for the
following applications:
• Ground loop checks on any earthing
system
• Continuity tests on earth bonding
circuits and connections
• Inspection of lightning protection
systems
• Leakage current measurement for
troubleshooting on earth ground
systems

Specifications
(Check the Fluke web for detailed specifications)

Fluke 1630

Range
0.025 to 1500 Ω
< app. 40 Ω
0.2 to 1000 mA
0.2 to 30 A

Resistance
Cntinuity buzzer
Leakage current
Current

Max. resolution
0.002 Ω
0.001 mA
0.01 A

Weight: 0.64 kg
Conductor Size: 35 mm approx.
Size (HxWxD): 257 mm x 100 mm x 47 mm
Battery type: 9 V IEC 6 LR 61
Two Year Warranty

Ground resistance measurements principle
Ground resistance measurements principle

Rg

R1

R2

R3

.....Rn

Equivalent circuit diagram

Included Accessories
Rugged carrying case with belt, Resistance test
loop, 9 V battery, Operating instructions.

R1

R2

Ordering Information
Fluke 1630

Earth Ground Clamp Meter

Rg

Rg

42

.....Rn

Installation Testers/
Portable Appliance Testers
Our multifunction testers have redefined the standards for ease-of-use.
Designed for ensuring fixed wiring is installed according to IEC 60364,
they perform all tests required to verify safety. Our Portable Appliance
Testers verify the safety and operation of portable appliances, and are
designed for ‘one-touch’ operation and a fast throughput.

43

1650B Series Multifunction
Installation Testers
Extra functionality, faster testing,
and as rugged as ever

Fluke 1653B

Fluke 1652B

Safer, easier installation testing. The
new 1650B Series builds on the rugged
reputation of the earlier 1650 Series,
only it’s re-designed to meet your need
for more productive test tools. With
new features like the fast, high current
loop test (including a non-trip test)
and a variable RCD trip current setting,
accuracy is even better and the test
cycle even faster. And with the addition
of a unique zero adapter accessory for
accurate mains test lead compensation,
the 1650B Series continues to set the
standard in installation testers. The
1650B Series testers verify the safety
of electrical installations in domestic,
commercial and industrial applications.
They can ensure that fixed wiring is
safe and correctly installed to meet the
requirements of IEC 60364, HD 384 and
BS 7671 17th Edition wiring regulations.

1653B - The complete tester for
advanced users

Fluke 1651B

especially contractors, everyone who
would want to have the best tool
available and always understands (or
know) how to use.

1652B - The ideal tester for
professional trouble-shooters
This is the instrument that is indeed
ideal for professional users due to its
additional functionality. It is also ideal
since even though it has high-end
features, it is still easy to use – even
after longer periods of non-use; because
operating it is intuitive and not forgotten
easily.

1651B - The everyday tester, for
every electrical installer
This is the instrument that can be
used every single day (day in, day out),
and covers all the basic needs. It is the
preferred tester for every front-line
electrician/installer.

This is the instrument that has it all, in
a word: it’s complete. From all the test
functions you need to in-built memory
for documenting results. This makes it
the complete solution for professionals,

Features

BS7671 17th Edition IEE Wiring
Regulations IEC 60364.6.61, HD 384

Included Accessories
6 AA Cell batteries
C1600 Hard carrying case
Zero Adapter
Mains test cord
TL165X STD Standard Test Lead Set
TL165/UK Fused Test Lead Set (UK only)
Padded carrying strap
Quick reference guide
TP165X Remote control probe and lead 1
Users manual on CD-ROM

1653B
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O

Zero adapter
Volts (V)
Frequency (Hz)
Insulation (RISO)
Continuity (RLO)
Fast high current loop test (ZI)
Loop test non trip mode (ZI)
Short Circuit Current (PSC,PEFC, IK)
RCD FI Trip TimeTest (FI, DDR)
Variable RCD current setting
Tests time-delayed RCD´s (S-type)
RCD Ramp Test (FI, DDR)
RCD Auto Test (FI, DDR)
Test of pulse sensitive RCD´s
Earth Resistance (RE)
Phase Sequence
Internal Memory
IR Interface for downloading data
Remote probe

1652B
O
O
O
O
O
O
O
O
O
O
O
O
O
O

1651B
O
O
O
O
O
O
O
O
O
O
O

O

O*

* Not in the UK

1 In the United Kingdom and Ireland: 1652B & 1653B only

Ordering Information
Fluke 1651B Multifunction Installation Tester
Fluke 1652B Multifunction Installation Tester
Fluke 1653B Multifunction Installation Tester

Recommended Accessories
See also page 48 for more details

Check the Fluke website for the various
software modules

TLK290
Test Probe Kit

44

MTC1363 (UK)
Mains Test Cord

MTC77 (Europe)
Mains Test Cord

ES165X (1653)
Earth Spike Test Kit

FVF-SC2 (1653)
See page 120

1650B Series Multifunction
Installation Testers
Extra functionality, faster testing,
and as rugged as ever
Specifications
(Check the Fluke web for detailed specifications)
AC Voltage Measurement
Range

Resolution

Accuracy
50 Hz – 60 Hz
± (0.8% + 3 digits)

Input Impedance

Overload Protection

0.1 V

3.3 MΩ

660 Vrms

Resolution

Test Current

Open Circuit Voltage

Accuracy

0.01 Ω
0.1 Ω
1Ω

> 200 mA

> 4V

± (1.5%+3 digits)

500 V
Continuity Testing
Range
(autoranging)
20 Ω
200 Ω
2000 Ω

Slim probe design
Thanks to its slim probe with integral test button,
you can safely make one-handed measurements
on hard to reach points, while keeping your eyes
on the panel. This remote probe is powered by
the tester so always operable (does not require
additional batteries!).

Zero Adapter
For easy, always reliable and accurate
compensation for test leads and mains cords.
This adapter can be used for all different kind
of mains plugs as well as test accessories like
probes, alligator clips etc.

Insulation Resistance Measurement
Model
Test Voltage
Insulation
Resistance Range
1653B
50 V
10 kΩ to 50 MΩ
1653B
100 V
20 MΩ to 100 MΩ
1653B
250 V
1652B
1651B
1653B
500 V
1652B
1651B
1653B
1000 V
1652B
1651B
Loop Impedance Measurement
Range
20 Ω
200 Ω
2000 Ω
PFC. PSC Test
Range
Resolution and Units
Accuracy

20 MΩ to 200 MΩ
20 MΩ
200 MΩ
500 MΩ
20 MΩ
200 MΩ
1000 MΩ

Resolution

Test Current

Accuracy

0.01 MΩ
0.01 MΩ
0.1 MΩ
0.01 MΩ
0.1 MΩ

1 mA @ 50 kΩ
1 mA @ 100 kΩ

± (3%+ 3 digits)
± (3%+ 3 digits)

1 mA @ 250 kΩ

± (1.5%+ 3 digits)

0.01 MΩ
0.1 MΩ
1 MΩ
0.1 MΩ
1 MΩ

1 mA @ 500 kΩ

± (1.5%+ 3 digits)
+ 10%

1 mA @ 1 MΩ

± (1.5%+ 3 digits)
+ 10%

Resolution
0.01 Ω
0.1 Ω
1Ω

Accuracy
No trip mode: ± (3% + 6 digits)
Hi current mode: ± (2% + 4 digits)

1000A / 10kA(50kA)
1A / 0.1kA
Determined by accuracy of loop resistance and mains
voltage measurements

Computation
Prospective Earth Fault Current (PEFC) or Prospective Short Circuit Current (PSC) determined by dividing
measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
RCD Testing
RCD Type
1651B
1652B
1653B
1
O
O
O
AC
2G
O
O
O
AC
3S
4
O
O
A
G
O
O
A
S
1
4
AC – responds to AC 2G – General, no delay 3S – Time delay
A - Responds to pulsed signal
Tripping Time Test (ΔT)
Current Settings
Multiplier
Test Current Accuracy
Trip Time Accuracy
10, 30, 100, 300, 500, 1000 mA, VAR
x 1/2
+ 0% - 10%
± (1% Reading + 1 digit)
10, 30, 100 mA
X5
+ 10% - 0%
± (1% Reading + 1 digit)
Tripping Current (Ramp) Test – Fluke 1653B and 1652B only
Current Range
Step size
Dwell time
50% to 110% of
10% of I Δ N
Type G
Type S
RCD’s rated current
300 ms/step
500 ms/step
Earth Resistance Test (RE) – Fluke 1653B only
Range
200 Ω
2000 Ω

Complete kit
All 1650B models are equipped with detachable
leads that can be replaced in case of damage
or loss. A durable hard case will protect your
instrument in tough field conditions.

Battery type: Alkaline supplied. usable
with 1.2 V NiCD or NiMH rechargeable
batteries
Size (HxWxD):
100 mm x 250 mm x 125 mm

Resolution
0.1 Ω
1Ω

Trip Current
Measurement Accuracy
± 5%
Accuracy
± (2% + 5 digits)
± (3.5% + 10 digits)

Weight: 1.17 kg
Three Years Warranty

45

6000 Series PAT Testers
Versatile PAT testing at your fingertips
The Fluke 6200 and 6500 PAT testers
verify the electrical safety and operation
of portable appliances in accordance
with relevant guidelines and regulations.
With powerful auto test capabilities and
simplified controls they increase the
number of tests you can perform per day
without compromizing results.

Fluke 6200

Fluke 6500

A choice of automatic and manual
PAT testers
Both models perform all the tests
required for class I and class II
appliances. For manual testing and low
volume applications, choose the costeffective 6200 PAT model. If you need a
more powerful instrument to test large
numbers of appliances, the 6500 is the
right choice.

Fluke simplifies portable
appliance testing
• Compact and lightweight…
Efficient to work with and easy to carry
around– and has extra space in the
hard case for accessories.
• One touch simplicity…
Pre-set and user-definable test routines
are initiated from a single button – to
speed up test procedures and save you
time on site.
• A better way of working…
Rapid data entry via a QWERTY
keyboard (or optional Fluke barcode
scanner) and fast data transfer from
the main memory or the Compact Flash
memory card (6500).

6200

6500

• Dedicated key for each test for ‘onetouch’ testing
• Pre-set pass/fail levels to save time
• Large backlit display for easy reading

As 6200 but also with:
• Integral QWERTY keyboard for rapid
data entry
• Slot for Compact Flash memory card for
back-up data storage and transfer to PC
• Pre-set, auto-test sequences for user
convenience

Also available with European mains socket.

Features

Included Accessories
Test lead, Test probe, Crocodile clip,
Mains cord

Ordering Information
Fluke 6200
Fluke 6500

PAT Tester
PAT Tester

Not available in all countries

Measurement functions
L N Mains Volts
Outside Limits Indicators
Null out facility for earth bond lead
Protective Earth Resistance PE (200mA)
Protective Earth Resistance PE (25A)
Insulation 500V dc
Protective Earth Conductor Current
Touch Current
Substitute Leakage Current
Appliance Power kVA
Appliance Load Current
Seven Segment Custom LCD
Graphical LCD
Back Light
Compact Flash Card receptacle
Serial Port - Printing / Downloading

O
O

6500
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O

External printer output
Front Panel QWERTY Key pad

O

O
O

IEC Lead Test
Auto-testing
Pass / Fail Level Programmable Indicators
Data Storage
Limited Data Storage
Polarity Checks
Graphical Help Menu On Line
Programme Mode
Real time clock

O

O
O
O
O

Front panel results management
230V BS1363 Test socket / 230V Mains BS1363 input power plug

46

6200
O
O
O
O
O
O
O
O
O
O
O
O

O
O

O

O
O
O
O
O
O

6000 Series PAT Testers

Specifications
The accuracy specification for the display range is defined as ± (%reading + digit counts) at 23 °C ± 5 °C, ≤ 75 %
RH. Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy
specification) per °C. The measurement range meets the service operating errors specified in EN61557-1: 1997,
EN61557-2: 1997 , EN61557-4: 1997.

Separate hard case
The compact Fluke PAT testers are supplied with a
hard carrying case that not only offers protection
during transit but also includes extra storage space for
accessories and other tools. They’re extremely light,
weighing approximately 3 kg (without case) and have
integral carrying handles for extra convenience.

Power-on Test

Touch Current Test

The test indicates reversed L-N, missing PE, and
measures the mains voltage and frequency.
Display Range
90 V to 264 V

Display Range

0 to 1.99 mA ac

Accuracy

± (4% + 2 counts)

Resolution

0.01 mA

Accuracy at 50 Hz

± (2% + 3 counts)

Resolution

0.1V (1V - model 6200)

Input Impedance

> 1 MΩ // 2.2 μF

Maximum Input Mains Voltage

300 V

Internal Resistance (via probe)

2 kΩ

Measuring method

Probe

The appliance under test is energized at mains potential.
Substitute Leakage Current Test
Display Range

0 to 19.99 mA ac

Display Range

0 to 19.99 Ω

Accuracy

± (5% + 5 counts)

Accuracy
(after Bond Test zeroing)
Resolution

± (5% +4 counts)

Resolution

0.01 mA

Test Current

Open Circuit Voltage

200 mA AC - 0% + 40% into
1.99Ω
25 A AC ± 20% into 25 mΩ
at 230 V
> 4 V AC, < 24 Vac

Bond Test zeroing

can subtract up to 1.99Ω

Earth Bond Test

0.01Ω

Test Voltage

35 V AC ± 20%

Operational Error

10%

Load/Leakage Test: Load Current
Display Range

0 to 13 A

Accuracy

± (4% + 2 counts)

Resolution

0.1 A

The appliance under test is energized at mains potential
Insulation Test (Riso)

Special PAT Kit
If you need a complete PAT tester solution,
a purpose made kit is available.
Fluke 6500/UK Kit Contains:
• 6500, Mainframe
• EXTL 100, Extension lead test adaptor
• SP Scan 15, Barcode scanner
• Fluke PowerPat Plus
• Pass 560R, Appliance pass labels
• Fail 100S, Appliance fail labels APP 1000,
Barcode appliance number labels

Load/Leakage Test: Load Power

Display Range

0 to 299 MΩ

Accuracy

Auto discharge time

± (5% + 2 counts) from 0.1
to 50 MΩ
± (10% + 2 counts) from 50
to 299 MΩ
0.01 MΩ (0 to 19.99 MΩ)
0.1 MΩ (20 to 199,9 MΩ)
1 MΩ (200 to 299 MΩ)
500 V DC - 0% + 25% at
500 kΩ load
> 1 mA at 500 kΩ load,
< 15 mA at 0 Ω
< 0.5 s for 1 μF

Max. Capacitive Load

Operational up to 1 μF

Resolution

Test Voltage
Test Current

Display Range

0 to 999 VA
1.0 kVA to 3.2 kVA
± (5% + 3 counts)

Accuracy
Resolution

1 VA (0 to 999 VA)
0.1 kVA (1.0 kVA to 3.2 kVA)
The appliance under test is energized at mains potential

Load/Leakage Test: Leakage Current
Display Range

0.25 to 19.99 mA

Accuracy

± (4% + 4 counts)

Resolution

0.01 mA

The appliance under test is energized at mains potential

(Kit contents may vary per country)

PELV Test
Accuracy at 50 Hz

± (2% + 3 counts)

Overload protection

300 Vrms

Warning threshold

25 Vrms

Display Screens
Size (HxWxD): 200 mm x 275 mm x 100 mm
Weight: 3 kg
Two Years Warranty

Substitute Leakage
Current Test

Earth Bond Test (RPE)

Recommended Accessories
See also page 48 for more details

Insulation Test (RISO)

Touch Current Test

Fluke PowerPat Plus
software

SP1000-02
Mini printer

SP-SCAN-15
Barcode scanner
(6500 Fluke only)

BDST3 Snap Tags
Cable Tie

PASS
Appliance 560R
Pass Labels

47

1650B Series/6000 Series
Accessories
Accessories for Fluke 1650B
Series Installation Testers

Accessories for Fluke 6500 Series Portable
Appliance Testers

PASS560R Appliance Pass Labels
ES165X Earth Spike Test Kit
(Fluke 1653B)

Quantity 500

SP1000 Mini Printer
Without using any additional software the
SP1000 can be used to directly printout stored
test records on to thermal paper. The printer
is compact and easily transported and is ideal
for test professionals who need to issue an
immediate written account of work carried
out. The printer is powered by a rechargeable
battery and comes complete with mains
charger and RS232 Printer Lead.

Earth Spike Test kit contents:
• Auxiliary earth probes
• Test connection leads and crocodile clips
• Purpose-made carry case

APP1000/APP2000 Bar Code Appliance
Number Labels
APP1000: Labels numbered 0001-1000
APP2000: Labels numbers 1001-2000
Label number >2000 on request

FVF-SC2 Fluke ViewForms Software
(Fluke 1653B)
To address the increasing demands for
reporting and documentation, Fluke presents
FlukeView Forms documenting software.
Download the data from the Fluke 1653B and
create an easy report. The Fluke ViewForms
Software also supports other Fluke tools. See
page 120.

Replacement thermal paper for the SP1000
Mini Printer

Fluke DMS software for
1650B/6000 Series

BDST3/BDST4 Snap Tags
BDST3: Cable Tie
BDST4: Clip On
Quantity 20. Without labels.

TLK 290 Test Probe Kit
• Kit includes three flexible socket probes and
a large alligator clip
• To be used on three phase sockets
• Probes have flexible width test points that fit
securely in 4 to 8 mm sockets
• CAT III 1000 V, 8 A

SP1000 Paper

EXTL100-02 (UK plug)

EXTL100-02 (Schuko plug)

EXTL100 Extension Lead Test Adaptor
Adaptor for testing extension leads. Allows
the earth test lead to be connected to the
extension leads to perform insulation and
earth bond tests.

The Fluke DMS (Data Management Software)
is an efficient program for administration and
reporting of installation tests in compliance
with EN 60364, DIN VDE 0100/0105, BS7671
17th edition wiring resulation and appliance
tests in compliance with DIN VDE 0701/0702,
ÖVE E 8701.

DMS 0100/INST Software for
Installation Tester Fluke 1653B
Supporting reports for Austria, Germany, UK,
Switzerland, Netherlands

DMS 0702/PAT Software for Portable
Appliance Tester Fluke 6500
Supporting reports for Austria, Germany, UK,
Netherlands

DMS COMPL PROF Software for the
Fluke 1653B and Fluke 6500
Supporting reports for Austria, Germany, UK,
Switzerland, Netherlands
MTC1363

MTC77

Mains Test Cord for 1650B series
MTC1363
MTC77

48

UK plug
Schuko plug

SPScan15 Barcode Scanner
Easy to use, low current, intelligent barcode
reader. SPScan15 can be used to scan barcodes
attached to curved surfaces or where actual
contact with the barcode surface is difficult.

Check the Fluke web for more information.

Digital Thermometers
For troubleshooting systems where temperature is a critical symptom,
our digital thermometers provide you with laboratory accuracy wherever
you need it. We offer a choice of non-contact, laser-guided infrared
thermometers for safely getting at hard-to-reach, electrically live or
particularly hot targets, and contact thermometers with a full range of
thermocouple probes.

49

See catalog page

Data logging (number of
measurements)
PC interface
Compatible with
FlukeView Forms
software

Adjustable emissivity
MIN/MAX readings
AVG readings
DIF readings
Backlit LCD
Bar graph display
Audible Hi/Lo alarm
Visible Hi/Lo alarm
Includes contact probe
Probe input (types)

Laser sighting

Close focus model
available
Recommended distance
to spot

Contact thermometers
For our complete range of contact
thermometers, see page 55.

50

Temperature range
Accuracy
Response time
Optical resolution

Infrared Thermometer
Selection Guide

52

O

-/O

single-point
laser

Up to 2 m

Fluke 62
-30 to 500 ºC
1.5%
< 500 mSec
10:1

52

O

-/O

single-poimt
laser

Up to 2.5 m

RTD

RTD

52

52

12 points

O
O

O
O

12 points

single-point
laser
O
O
O
O
O

Up to 7.5 m

Fluke 68
- 32 to 760 ºC
1%
< 500 mSec
50:1

single-point
laser
O
O
O
O
O

Up to 4.5 m

Fluke 66
- 32 to 600 ºC
1%
< 500 mSec
30:1

Heating/ventilation/air conditioning/
refrigeration
Leaky ductwork
Thermostats
Temperature balancing
Steam distribution systems
Compressor lines

Fluke 60 Series
Fluke 63
- 32 to 535 ºC
1%
< 500 mSec
12:1

Plant/facilities maintenance
Preventive and predictive maintenance
Energy audits
Vehicle and fleet maintenance
programs
Faulty electrical/circuit connections
Petrochemical/hazardous locations
Motors, pumps and bearings

52

O

single-point
laser

Up to 2 m

Fluke 61
-18 to 275 ºC
2%
< 500 mSec
8:1

53

20 points

O
O
O
Type K
Thermocouple

single-point
laser
O
O
O
O
O

Up to 4.5 m

Fluke 560 Series
Fluke 566
- 40 to 650 ºC
1%
< 500 mSec
30:1

O

Safety and protection
Fire localization
Hazardous materials
Faulty ballasts
Search and rescue
Smoldering embers
Equipment maintenance

Recommended Applications

51

RS232
O
53

100 points

300 mm
(with close
focus) up to
10.5 m
3-point
laser
O
O
O
O
O
O
O
O
O
Type K
Thermocouple

USB

51

O
O
O/O/-

300 mm
(with close
focus) up to
10.5 m
3-point
laser
O
O

Fluke 570 Series
Fluke 572
Fluke 574
- 30 to 900 ºC
- 30 to 900 ºC
0.75%
0.75%
< 250 mSec
< 250 mSec
60:1 (50:1
60:1 (50:1
with close
with close
focus)
focus)
O
O

99 points

O
O
O
Type K
Thermocouple

single-point
laser
O
O
O
O
O

Up to 7.5 m

Fluke 568
- 40 to 800 ºC
1%
< 500 mSec
50:1

Manufacturing processes
Molding temperature measurement
Printing, paper and converting
Thermoforming plastics
Electronics
Paint curing/drying
Food
Chemical and pharmaceutical

54

O
Type K
Thermocouple

O
O

single-point
laser
O
O

Up to 2.5 m

Fluke 561
- 40 to 550 ºC
1%
< 500 mSec
12:1

Infrared Thermometer
Selection Guide

570 Series
Precision Infrared Thermometers
Measure temperature with ease and
precision
The Fluke 570 series are the most
advanced IR non-contact thermometers,
and are ideal for predictive and
preventative maintenance applications.
Offering a broad temperature range
and a true dimension laser sighting
system for precise targeting resulting
in more accurate measurements. When
requiring analysis and documentation
use the 100-point data logging and
software for graphing and analysis.
From close-up electrical connections, to
far-distance room balancing checks, the
Fluke 570 series can take IR temperature
measurements with ease and precision.

• Enhanced optics allows measurements
of smaller objects from farther away
• True Dimension™ three-dot laser
sighting system highlights the true
diameter of measurement spots at all
distances
• Adjustable emissivity setting and 30
pre-set common material values for
more accurate measurements
• 100 data point memory for storage of
measurements (Fluke 574).

Fluke 574

Features
572
Temperature range
Optical resolution

574
-30 to 900ºC
Standard: 60:1
Close focus: 50:1

3 dot laser beam for accurate targeting
Adjustable emissivity
Bar graph display
Backlit LCD display
Use selectable ºC or ºF
Audible and visible Hi/Lo Alarm
MIN/MAX
AVG/DIF readings
Datalogging (number of measurements)
PC interface

O
O
O
O
O
O/O

O
O
O
O
O
O/O
O
O
100
RS232

Specifications
572

Fluke 572

Included Accessories
Fluke 572: Hard case, 2 batteries
Fluke 574: Hard case, 2 batteries, Thermocouple
K probe, 220V power supply, IRGraph software,
RS232 cable

Ordering Information
Fluke 572
Precision Infrared Thermometer
Fluke 574
Precision Infrared Thermometer
Fluke 572CF Precision Infrared Thermometer
with close focus option
Fluke 574CF Precision Infrared Thermometer
with close focus option

Temperature range
Response time
Resolution
Repeatability
Accuracy: (assumes ambient operating temperature of 23 ºC to 25 ºC )
Typical distance to target
Emissivity

574
-30 to 900°C
250ms (95 % of reading)
0.1°C of reading up to 900°C
±0.5% of reading or ±1°C*
±0.75% of reading, ±0.75°C *
10,5 m
Digitally adjustable from 0.10 to 1.0
by 0.01

*whichever is greater.

Battery Life: 10 hours typical
Weight: 0.480 kg
Size (HxWxD): 200 mm x 170 mm x 55 mm
Two years warranty

Recommended Accessories

AN5
Analog data cable

C570
See page 118

51

60 Series
Infrared Thermometers
Point, press and read temperature
The 60 Series IR thermometers
feature:

The Fluke 60 Series non-contact
thermometers are the ideal professional
diagnostic tools for quick and accurate
temperature measurements.
These handheld tools are ideal for
measuring surface temperatures of
rotating, hard-to-reach, electricity live
or dangerously hot targets like electrical
motors and – panels, and heating and
ventilation systems.
The laser sighting system guides
measurements to the right target and in
less than a second, the large temperature
display provides a readout of the surface
temperature.

Fluke 68

Fluke 66

• Laser guided sighting system for easy
targeting with 1% accuracy
• Up to 12 points datalogging with Min/
Max/Average functions
• Up to 50:1 optical resolution
• Choice between models with fixed or
adjustable emissivity
• Backlit display for easy reading in the
dark
• Temperatures up to 760°C

Features
61

62

63

66

68

Flat grip

Pistol grip

Pistol grip

Pistol grip

Pistol grip

Temperature range

-18 to 275°C

-30 to 500 °C

-32 to 535°C

-32 to 600°C

-32 to 760°C

Optical resolution

8:1

10:1

12:1

30:1

50:1

Laser beam for accurate targeting

O
O
O

O
O
O

O
O
O

Max

Max

O
O
O
O
O
O
O

O
O
O
O
O
O
O

Form factor

Fluke 63
Fluke 62

Backlit LCD display
Use selectable °C or °F
Min/max/avg/dif readings
Datalogging
Hi/Lo Alarm
Adjustable emissivity

Specifications
Range
Response time
Resolution
Repeatability
(% of reading)
Accuracy:

Fluke 61

The Fluke FoodPro™ thermometer
series provide advanced
temperature measurement solutions
for the foodservice industry. Check
the Fluke web for more information.

61

62

63

66

68

- 18 to 275ºC

- 30 to 275 ºC

- 32 to 535 ºC

- 32 to 600 ºC

- 32 to 760 ºC

< 500ms

< 500ms
(95 % of reading)
0.2 ºC

≤ 0.5 second

≤ 0.5 second

≤ 0.5 second

0.2 ºC

0.2 ºC

0.1 ºC

0.1 ºC

± 2%
or ± 2 ºC*
For targets at:

± 0.5%
or < ± 1 ºC*
For targets at:

± 0.5%
or ≤ ± 1 ºC*
For targets at:

± 0.5%
or ≤ ± 1 ºC*
For targets at:

± 0.5%
or ≤ ± 1 ºC*
For targets at:

(assumes ambient
operating temperature
of 23ºC)

-18 to -1ºC: ± 3ºC
-1 to 275ºC: ± 2% of
reading or ± 2ºC

10 °C to 30 °C: ±1 °C
± 1.5% of reading
or ± 1.5°C whichever
is greater over
the balance of the range

-32 to -26°C: ± 3°C
-26 to -18°C: ± 2.5°C
-18 to 23°C: ± 2°C
23°C -510°C: ± 1%
of reading or ± 1°C*
For targets
above 510°C:
± 1.5% of reading

-32 to -26°C: ± 3°C
-26 to -18°C: ± 2.5°C
-18 to 23°C: ± 2°C
For targets above
23 ºC:
± 1% of reading
or ± 1 ºC*

-32 to -26°C: ± 3°C
-26 to -18°C: ± 2.5°C
-18 to 23°C: ± 2°C
For targets above
23 ºC:
± 1% of reading
or ± 1 ºC*

Typical distance to
target
Emissivity

Up to 1m

Up to 1.5 m

Up to 2 m

5m

8m

Fixed at 0.95

Pre-set to 0.95

Fixed at 0.95

Digitally adjustable
from 0.1 to 1.0
by 0.01

Digitally adjustable
from 0.1 to 1.0
by 0.01

* whichever is greater

Included Accessories
Fluke 61: 9V Battery
Fluke 62: 9V Battery, storage holster
Fluke 63, 66 and 68: Hard carrying case,
9V batteries

Battery Life:
Fluke 66 and 68:
Fluke 63:
Fluke 62:
Fluke 61:

20 hours with laser and backlight on 50%
10 hours with laser and backlight on
12 hours with laser and backlight on
12 hours with laser and backlight on

Size (HxWxD):
Fluke 63, 66 and 68:
Fluke 62:
Fluke 61:

200 mm x 160 mm x 55 mm
152 mm x 101 mm x 38 mm
184 mm x 45 mm x 38 mm

Weight:
Fluke 63, 66 and 68:
Fluke 62:
0.200 kg
Fluke 61:
0.227 kg

0.320 kg

Fluke 62: 2 years warranty
Other models: one year warranty

Ordering information
Fluke 61
Infrared Thermometer
Fluke 62
Mini Infrared Thermometer
Fluke 63
Infrared Thermometer
Fluke 66
Infrared Thermometer
Fluke 68
Infrared Thermometer
Fluke 62/322/1AC (see page 5)
Fluke T5-600/62/1AC (see page 5)

Kits

Recommended Accessories

C23
See page 118

52

Fluke 62/322 kit

T5-600/62/1AC

80PR-60
See page 117

H6
See page 119

566 and 568
Multipurpose Thermometers
The two-in-one infrared and contact thermometer with an innovative graphical display
With a straight-forward, menu-driven
user interface and graphical display,
the Fluke 566 and 568 multipurpose
thermometers make even complex
temperature measurements easy. Quickly
navigate and adjust emissivity, start data
logging, or turn on and off alarms, with
just a few pushes of a button. For added
convenience, both rugged handheld
thermometers combine contact and
non-contact temperature measurement
capability, providing a total temperature
measurement solution for any service
and maintenance program.

Fluke 566

• Easily access advanced features with
the soft-key buttons and graphical
display
• Measure smaller targets from farther
away using the IR thermometer
• Adjustable emissivity and built-in table
of common materials for higher IR
accuracy
• Quickly identify problems with the MIN,
MAX, AVG, and DIF functions
• 2-color flashing alarm alerts you
visually when measurements exceed
limits
• Includes Type K thermocouple bead
probe
• Compatible with all standard miniconnector K-type thermocouples
• Data logging with a date/time stamp
• Soft rubber boot for increased
ruggedness
• User interface available in 6 languages

Fluke 568

Choose your language

Select the measurement surface

See complete measurement details
in seconds

Specifications
(Check the Fluke web for detailed specifications)
Infrared temperature range
Infrared accuracy

The Fluke 566 and included accessories

Display resolution
Infrared spectral response
Infrared response time
Input temperature range
Input accuracy
D:S (Distance to measurement spot size)
Laser sighting
Minimum spot size
Emissivity adjustment
Data logging with Date/Time stamp
PC interface and cable
Hi/Low alarms
Min/Max/Avg/Dif
Display
Backlight
Trigger Lock
Switchable between Celsius and Fahrenheit

The Fluke 568 and included accessories

Included accessories

566
568
-40 °C to 650 °C
-40 °C to 800 °C
< 0 °C : ± (1.0 °C + 0.1°/1 °C);
> 0 °C : ± 1 % or ± 1.0 °C, whichever is greater
0.1 °C
8 μm to 14 μm
< 500 msec
-270 °C to 1372 °C
-270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C)
-40 °C to 1372 °C: ± 1 % or 1 °C, whichever is greater
30:1
50:1
Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
19 mm
By built-in table of common materials or digitally adjustable
from 0.10 to 1.00 by 0.01
20 points
99 points
None
USB 2.0 with FlukeView®
Forms software
Audible and two-color visual
Yes
Dot matrix 98 x 96 pixels with function menus
Two levels, normal and extra bright for darker environments
Yes
Yes

Power: 2 AA/LR6 Batteries (566); 2 AA/LR6
Batteries and USB for use with a PC (568)
Battery life: Used continuously; laser and
backlight on: 12 hours; laser and backlight off:
100 hours

FlukeView® Forms software (568 only), USB
cable (568 only), K-type thermocouple bead
probe, 2 AA batteries, hard carrying case,
quick start guide, and users manual.

Weight: 0.965 kg (566); 1.026 kg (568)
Size (HxLxW): 25.4 cm x 19.1 cm x 6.9 cm
Operating temperature: 0 °C to 50 °C
Storage temperature: -20 °C to 60 °C
Two years warranty

Recommended Accessories

Ordering information
Fluke 566
Fluke 568

Infrared thermometer
Infrared thermometer
H6
See page 119

80PK-8
See page 116

80PK-9
See page 116

80PK-11
See page 116

80PK-25
See page 116

80PK-26
See page 116

53

561
Multipurpose Thermometer
Combined Infrared and Contact Thermometer

Fluke 561

The Fluke 561 combines the temperature
measurement functions that industrial,
electrical, and HVAC/R professionals
need, all in one tool. It measures both
IR and contact temperature, replacing
several other test tools. It’s fast, efficient,
and easy to use, saving you valuable time
and effort. With the Fluke 561, you can
take contact and ambient temperatures
in the way that’s best for you. Use the IR
thermometer to measure hot, moving,
electrically energized, and hard-toreach objects instantly. Check motors,
insulation, breakers, radiant heating,
pipes, corroded connections, and wires.
Plus, scan ducts, and other hard-to-reach
objects from the floor—leave your ladder
in the truck. You can use the Fluke 561’s
handy Velcro® pipe probe or, plug in any
industry standard, K-type mini-connector
thermocouple probe you already own.

• IR thermometer for quick
measurements up close or at a distance
• Single-point laser sighting
• Easy emissivity adjustment for
measuring pipes and ducts more
accurately
• Includes a Velcro pipe probe for superheat and sub-cooling as well as other
surface contact measurements
• Also compatible with all standard miniconnector K-type thermocouples
• MIN, MAX and DIF temperature
readings
• Lightweight (only 340 grams) and
portable
• Includes measurement guide

Specifications

The Fluke 561 includes everything you need for
immediate inspections.

Temperature range
Display resolution
D:S (Distance to spot size)
Easy emissivity selector
Display accuracy (Assumes ambient operating
temperature of 23° to 25°C)
Response time
Repeatability
Spectral focus
Laser sighting
Laser shutoff
Laser power
Relative humidity
Power
Display hold
Backlit display
Operating temperature
Storage temperature
MAX, MIN, DIF temperatures
Thermocouple type K mini-adapter input
Thermocouple type K Velcro pipe probe
Measurement guide

-40° to 550°C
0.1° of reading
12:1
Adjustable with three settings: low (0.3), medium (0.7), high (0.95)
± 1.0% of reading or ± 1°C, whichever is greater; below 0°C, ± 1°C, ± 1°/1°
500 mSec (95% or reading)
± 0.5% of reading or ± 1°C, whichever is greater
8 μm to 14 μm
Single-point laser
Laser turns off above ambient temperature of 40°C
Class 2 (II) operation; output ‹ 1 mW, wavelength 630 nm to 670 nm
10% to 90% RH non-condensing, at < 30°C
2 AA batteries (alkaline or NiCD)
7 seconds
Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery,
F/C indicator, and Scan/Hold options
0° to 50°C
-20 to 65°C
Yes
Yes, compatible with industry standard type K probes with mini-connector
Yes, with a temperature range of 0° to 100°C and accuracy of ± 2.2°C
Yes

Battery Life (alkaline): 12 hours
Weight: 340 grams
Size (HxLxW): 176,9 mm x 163,6 mm x 51,8 mm Two years warranty

Included accessories
Thermocouple K-type Velcro pipe probe,
hand carrying case, 2 AA batteries and user
manual with measurement guide.

Recommended Accessories

Ordering information
Fluke 561

HVACPro Thermometer

H6
Se page 119

54

80-PK-1
See page 116

80PK-8
See page 116

80PK-25
See page 116

50 Series II Thermometers
Laboratory accuracy. Wherever you go.
Additional features for the 53 and
54 Series II:

The Fluke 50 Series II contact
thermometers offer fast response and
laboratory accuracy (0.05% + 0.3°C) in
a rugged handheld test tool.
• Large backlit dual display shows any
combination of T1, T2 (52 and 54 only),
T1-T2 (52 and 54 only) plus MIN, MAX,
or AVG
• Relative time clock on MIN, MAX, and
AVG provides a time reference for major
events
• Electronic Offset function allows
compensation of thermocouple errors
to maximize overall accuracy
• Readout in °C, °F, or Kelvin (K)
• Sleep mode increases battery life
• Battery door allows easy battery
replacement without breaking the
calibration seal

• Data Logging up to 500 points of data
with user adjustable recording interval
• Real time clock captures the exact time
of day when events occur
• Recall function allows logged data to be
easily reviewed on the meter display
• IR communication port allows data to
be exported to optional FlukeView®
Temperature PC software

Features
Thermocouple types
Number of inputs
Time stamp
Splash/Dust resistant
Dual display with backlight
Min/Max/Avg recording
(T1-T2) True differential
Data logging up to 500 points
IR data port for interface
to PC
Compatible with optional
FlukeView Software

Fluke 54 II

51 II
J,K,T,E
Single
Relative Time
O
O
O

52 II
J,K,T,E
Dual
Relative Time
O
O
O
O

53 II
J,K,T,E,N,R,S
Single
Time of Day
O
O
O
O
O

54 II
J,K,T,E,N,R,S
Dual
Time of Day
O
O
O
O
O
O

O

O

Specifications
Fluke 51 II

Fluke 52 II

Fluke 53 II

Included Accessories
Impact absorbing holster
Two bead probe thermocouples 80PK-1 (54+52)
One bead probe thermocouple 80PK-1 (51+53)

Ordering Information
Fluke 51 II
Fluke 52 II
Fluke 53 II
Fluke 54 II
FVF-SC1

Thermometer
Thermometer
Thermometer
Thermometer
FlukeView Forms Software
including interface cable

Temperature range:
J-type Thermocouples
K-type Thermocouples
T-type Thermocouples
E-type Thermocouples
N-type** Thermocouples
R** and S-type** Thermocouples
Temperature accuracy
Above –100°C (-148°F):
J, K, T, E, and N-type**
R** and S-type**
Below –100°C (-148°F):
J, K, E, and N-types
T-type

-210°C to 1200°C
-200°C to 1372°C
-250°C to 400°C
-150°C to 1000°C
-200°C to 1300°C
0°C to 1767°C

± [ 0.05% + 0.3°C ]
± [ 0.05% + 0.4°C ]
± [ 0.20% + 0.3°C ]
± [ 0.50% + 0.3°C ]

**Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type

Battery life: 1000 hours typical, AA
Size (HxWxD): 173 x 86 x 38 mm

Weight: 0.4 kg
Three Year Warranty

Recommended Accessories

C25
See page 118

80PK-26
See page 116

80PK-25
See page 116

FVF-SC1
See page 120

TPAK
See page 120

55

1523 and 1524
Reference Thermometers
A new standard in
accuracy and versatility.
Measure, graph and record three
sensor types with one tool. The Fluke
1523/24 Reference Thermometer deliver
high accuracy, wide measurement
range, logging, and trending, all in a
handheld tool you can take anywhere.
For top accuracy, a memory chip inside
the probe connector feeds probe
calibration information to the readout.
In addition, any thermocouple with
a mini-thermocouple connector can
be read using the optional universal
thermocouple adapter. Choose the 1523
for single channel or the 1524 for dual
channel measurement.

Three sensor types

Fluke 1524

Fluke 1523

• PRTs: –200 °C to 1000 °C
• Thermocouples –200 °C to 2315 °C
• Precision thermistors: –50 °C to 150 °C

High accuracy
• PRTs: ±0.011 °C
• Thermocouples: ±0.24 °C for J,K,L,M
• Precision thermistors: ±0.002 °C

Fast measurement
• PRTs: up to 0.45 seconds/sample
• Thermocouples: up to 0.3 seconds/
sample
• Precision thermistors: up to 0.3
seconds/sample

Two models
• 1523: Single channel standard model;
memory for 25 readings & statistics
• 1524: Two channels; memory for 25
readings and statistics plus logging
15,000 measurements; real-time clock
for time and date stamps

Features
Note: The 1523/24 are pictured with probes connected which may
be purchased seperately.

Included Accessories
NIST traceable certificate of calibration, users
guide, CD-ROM (contains technical manual),
12 V dc universal power supply, RS-232 cable,
9940 I/O ToolKit software

Sensor Types
Thermocouple Types
Number of inputs
Data trending (graphing)
Graphical display with backlight
Min/Max/Avg/Standard deviation recording
High speed measurement
RS-232 PC communications
T1-T2 True differential
Data logging up to 15,000 points
Time and date stamp

1523
1524
PRT & RTD, Thermistor, and Thermocouple
B,C,E,J,K,L,M,N,R,S,T,U
Single
Dual
O
O
O
O
O
O
O
O
O
O
O
O
O

Ordering Information
Fluke 1523*
Reference Thermometer
Fluke 1524*
Reference Thermometer
Fluke 1523-P1 Reference Thermometer,
PRT(–200 °C to 420 °C, 6.35
mm x 298 mm), Universal
Thermocouple Adapter, TPAK,
and Case
Fluke 1524-P1 Reference Thermometer,
PRT(–200 °C to 420 °C, 6.35
mm x 298 mm), Universal
Thermocouple Adapter, TPAK,
and Case
* Requires an optional probe

Specifications
(Check the Fluke web for detailed specifications)
Temperature range
Thermocouple
PRT & RTD
Thermistor
Resolution and best accuracy
Thermocouple
PRT & RTD
Thermistor
Operating temperature
Storage temperature

–200 °C to 2315 °C
–200 °C to 1000 °C
–50 °C to 150 °C
0.01 °, ±0.24 °C
0.001 °, ±0.011 °C
0.001 °, ±0.002 °C
–10 °C to 60 °C
–20 °C to 70 °C

Optional Accessories
2384-P
2384-T
2373-LPRT

INFO-CON Connector, PRT
(Gray Cap), Spare
INFO-CON Connector,
Thermocouple (Blue Cap),
Spare
RTD Adapter, Lemo to
Mini Grabbers (4-wire)

Battery life (alkaline): 20 hours
Power supply: Universal 12 Vdc
Size (HxWxD): 200 x 96 x 47 mm
Weight: 0.65 kg
Warranty: 1 year

Recommended Accessories

Optional probes:
5616-12-P
5615-9-P
5610-9-P
56

PRT, 6.35 mm x 298 mm,
–200 °C to 420 °C
PRT, 4.76 mm x 229 mm,
–200 °C to 420 °C
Thermistor, 3.2 mm x 229 mm,
0 °C to 100 °C

TPAK

FLK80P1
(80PK1 with universal
thermocouple adapter)

FLK80P3
(80PK-3A with universal
thermocouple adapter)

2384P and 2384T
Spare INFO-CON Adapters

2373-LTC
Universal TC adapter

Thermal Imagers
Temperature changes can indicate problems in many everyday applications and a thermal imager makes it quick and easy to visually check
surface temperatures. Often problems can be discovered before contact
measurements even need to be made. Fluke offers a complete range of
handheld thermal imagers for both industrial and building diagnostic
applications. Models are available for any budget.

57

Ti Series Thermal Imagers
Find it, fix it, fast!
Temperature changes can indicate problems
in many areas you see everyday, some
include:
• Inside electrical distribution and service
(Switch gear, panels, controls,
fuses,transformers, receptacles, lighting,
conductors, bus bars, motor control
centers)
• Motors, pumps and mechanical (Electric
motors and generators, pumps,
compressors, evaporators, bearings,
couplings, gearboxes, gaskets/seals, belts,
rollers, disconnects)
• Process (Tanks and vessels, pipes, valves
and traps, reactors, process insulation)
• HVAC/R (air conditioning, heating, air
handlers, refrigeration)
• Outside electrical distribution - utilities
(Transformers, bushings, insulators,
transmission lines, other exterior
conductors, service connections,
disconnects, capacitor banks)

IR-Fusion® Technology: Infrared and
visual images fused together in one image
See things both ways - Infrared and
visual (visible light) images fused
together communicating critical
information faster and easier –
traditional infrared images are no longer
enough. Patented IR-Fusion® Technology,
only available from Fluke, simultaneously
captures a digital photo and the infrared
image and fuses them together taking
the mystery out of IR image analysis.

Full IR

Picture-in-Picture

IR/Visible Alarm

Full Visible Light

Alpha Blending

www.fluke.eu/ti

Overheating bearing cap

Three-phase switch-gear
load imbalance

SmartView® Software

Overheated motor

Cool corner in a building

Fluke SmartView® software is included with each Fluke
Thermal Imager. This powerful software is a modular
suite of tools that annotates, views, edits and analyzes
IR images.
It also generates fully customizable and professionallooking reports in a few easy steps. The IR-Fusion
technology is fully supported.

Thermal imaging
application video
This video covers the principles of thermal
imaging and looks at using this powerful
troubleshooting technology in electrical,
electro-mechanical and process control
applications. Go to www.fluke.co.uk/ti or
www.fluke.eu/ti to see the video.

FREE webinars/webcasts on
Thermal Imaging
Keep up-to-date on the latest troubleshooting
techniques. Attend a FREE Fluke webinar (web-based
seminar) about thermal imaging applications.
Go to www.fluke.eu/ti for more information.

58

CRange IRWindows
Increase the safety and speed of electrical
thermography
Infrared windows mount into panel doors
and covers for switchgear, transformers,
bus bars and other live electrical
equipment, allowing Infrared, Ultraviolet,
Visual and IRfusion technologies to be
used without exposing personnel to live
equipment.
All infrared windows from Fluke use
the unique Quadraband™ multispectral
optic, allowing inspection with any
camera for total flexibility both now and
in the future.

• Reduce the arc flash risk associated
with electrical thermography
• Increase efficiency as thermographer
can work alone without being
accompanied by an electrician to isolate
and open panels
• Stay safety compliant with NFPA70E
and other safety protocols and leave the
panels closed
• Extend the life of your equipment with
more frequent IR scans
• Easy to install
• Durable enough to withstand extreme
outdoor conditions yet practical for
indoor applications as well.

Specifications
(Check the Fluke web for detailed specifications)

Included Accessories
Installation CD, self-adhesive drilling
template, security access key, warranty
statement.

Ordering Information
FLK-075-CLKT
FLK-100-CLKT
IP-200-UK

75mm C-Range IR Window,
Kwik Twist
100mm C-Range IR Window,
Kwik Twist
Window Installation Kit
220/240V

Optic Data
Crystal Insert Diameter
Viewing Aperture Diameter
Viewing Aperture Area
Thickness
CLIRVU Coating
Shortwave IR Capable
Midwave IR Capable
Longwave IR Capable
Ultraviolet (UV) Capable
Visual Capable
Fusion Capable
General
Maximum Temperature
Gaskets
Body
Optic
Gaskets
IP rating
NEMA rating
Vibration rating
Humidity rating
Pull out strength

FLK-075-CLKT

FLK-100-CLKT

75 mm
68 mm
3632 mm2
2 mm

100 mm
89 mm
6322 mm2
4 mm

O
O
O
O
O
O
O

O
O
O
O
O
O
O

250º C
659 º C
1400º C
Low Smoke & Fume (LSF) compliant silicone
IP65
Typo 3/12 (UL & CSA Third Party Certified)
IEC60068-2-6
IEC60068-2-3
Up to 630 kg

Warranty: Lifetime replacement against manufacturing defects

59

Ti9/Ti10
Electrical Thermal Imagers
The rugged and affordable tools for
electricians and technicians
Get the full picture instantly with the
Fluke Ti9/Ti10 thermal imagers. Built
for tough work environments, these
fully radiometric imagers are ideal for
detecting problems in a wide range of
equipment including switchgear, motor
control centers and lighting systems.

Fluke Ti10

• Enhanced problem detection and
analysis capabilities with patent
pending
IR-Fusion® Technology (Ti10)
• Intuitive, three-button menu is easy to
use ... simply navigate with the push of
a thumb
• Store more than 3.000 screen images
(.bmp format) or 1.200 fully radiometric
images (.IS2 format) on included 2 GB
SD memory card
• The Fluke Ti9 can be upgraded to a full
Fluke Ti10 with IR-Fusion at a later time.

• Delivers the clear images to find
problems fast with its 160x120 sensor
• Even the smallest details become
visible with the large, widescreen full
color LCD display
• Optimized for field use in harsh work
environments
- Engineered and tested to withstand a
2 meter drop
- Withstands dust and water – tested to
an IP54 rating
- Innovative protective lens cover
protects the lens when not in use

Specifications
(Check the Fluke web for detailed specifications)
Fluke Ti9

New
Fluke Ti9

Thermal imaging performance
Detector type
Field of view (FOV)
Spatial resolution (IFOV)
Min focus distance
Thermal sensitivity (NETD)
Minimum span (Auto/Manual)
Focus
Visual imaging performance
Min focus distance
On camera operating modes
Visible light camera
Temperature measurement
Temperature range
Accuracy
Measurement modes
Image presentation
Digital display
LCD backlight
Palettes
Image and data storage
Storage medium
File formats supported
Controls and adjustments
Set-up controls
Language selection
Image controls
Power
Battery type
Battery operating time

Fluke Ti10

160 x 120 Focal Plane Array, uncooled microbolometer
23 º horizontal x 17 º vertical
2.5 mrad
15 cm
≤0.2 °C at 30 °C (200 mK)
10 ˚C / 5 ˚C
Manual
46 cm
Picture-in-Picture and full screen IR
1.3 MegaPixel
-20 ˚C to 250 ˚C
± 5 °C or 5%
Center point
9.1 cm (3.6") landscape color VGA (640x480) LCD
Selectable bright or auto
Ironbow, blue-red, high contrast, grey
2GB SD Card (3000 .bmp IR images/1200 .IS2 images)
JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Date/time,˚C/˚F, language
Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Smooth auto scaling and manual scaling
Internal rechargeable battery NiMh (included)
3 to 4 hours continuous operation

Complete package

Included Accessories
SmartView® software
2 GB SD card
SD card reader
Rugged hard carrying case
Soft carrying case
Hand strap
Rechargeable battery
AC charger/power supply
User manual
Training DVD

Battery life: 3 to 4 hours continuous operation
Water and dust resistant: IP54
Size (HxWxD): 267 x 127 x 152 mm
Weight: 1.2 kg
Two Years Warranty

Recommended Accessories

Ordering Information
60

Fluke Ti9
Fluke Ti10

Electrical Thermal Imager
Thermal Imager

Ti-Visor
Sun Visor
(for complete Ti Series)

Ti-Car Charger
Car charger

Ti-TRIPOD
Tripod Mounting Base
Accessories
(for complete Ti Series)

Ti25/Ti32
Industrial Thermal Imagers
New

The ultimate tools for troubleshooting and
maintenance
NETD of 0.1ºC for the Ti25 and 0.05ºC for
the Ti32 to view the smallest details.
For added versatility and special
applications, the Ti32 includes two fieldswappable, rechargeable batteries. Use
the optional telephoto and wide-angle
lens to bring distant and wide views into
sharp focus.

The Fluke Ti32 combines a powerful
320x240 sensor into the award winning,
rugged design of the Fluke Ti25,
delivering the first industrial grade, high
performance thermal imager. The result
is strikingly crisp, detailed images that,
blended with patented IR-Fusion®, are
sure to make a lasting impression.
The Fluke Ti32 and Ti25 have all the
features of the Fluke Ti10, but with an

Specifications
Fluke Ti32

(Check the Fluke web for detailed specifications)
Fluke Ti25
Thermal imaging performance
Detector type

Fluke Ti25

Field of view (FOV)
Spatial resolution (IFOV)
Min focus distance
Thermal sensitivity (NETD)
Minimum span (Auto/Manual)
Focus
Optional lenses
Telephoto infrared lens type
Wide-angle infrared lens type
Visual imaging performance
Min focus distance
On camera operating modes
Color Alarm
Visible light camera
Temperature measurement
Temperature range
Accuracy
Measurement modes
Image presentation
Digital display
LCD backlight
Palettes

O
O
46 cm
Picture-in-Picture and full screen IR plus Blending
High temperature alarm
1.3 MegaPixel
2.0 MegaPixel
-20 ˚C to 350 ˚C

-20 ˚C to 600 ˚C
± 2 °C or 2%
Center point and hot and cold markers

9.1 cm (3.6") landscape color VGA (640x480) LCD
Selectable bright or auto
Ironbow, Blue-Red, High Contrast, Amber, Hot
Ironbow, Blue-Red, High Contrast, Amber,
Metal, Grey
Amber Inverted, Hot Metal, Grayscale,
Grayscale Inverted

Palettes Ultra Contrast
Voice Annotation
Voice annotation
Image and data storage
Storage medium
File formats supported
Controls and adjustments

O
O

Complete package

Battery operating time

O

2GB SD Card (3000 .bmp IR images/1200 .IS2 images)
JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Date/time, Cº/ºF, language
On screen emissivity correction
On-screen reflected background temperature compensation
On-screen transmission correction
Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Smooth auto scaling and manual scaling

Set-up controls
Language selection
Image controls
Power
Battery type

Fluke Ti32

160 x 120 Focal Plane Array, uncooled
320 x 240 Focal Plane Array, uncooled
microbolometer
microbolometer
23 º horizontal x 17 º vertical
2.5 mrad
1.25 mrad
15 cm
≤0.1 °C at 30 °C (100 mK)
≤0.05 °C at 30 °C (50 mK)
2.5 ˚C / 5 ˚C
Manual

Internal rechargeable battery NiMh (included)
3 to 4 hours continuous operation

Two replaceable rechargeable battery packs
(Lithium ion)
4+ hours per battery pack

Included Accessories
SmartView® software
2 GB SD card
SD card reader
Rugged hard carrying case
Soft carrying case
Hand strap
Rechargeable battery
AC charger/power supply
User manual
Training DVD

Water and dust resistant: IP54
Size (HxWxD): Ti25: 267 x 127 x 152 mm
Ti32: 277 x 122 x 170 mm
Weight: Ti25: 1.2 kg
Ti32: 1.05 kg
Two Years Warranty

Recommended Accessories

Ordering Information
Fluke Ti25
Fluke Ti32

Industrial Thermal Imager
Industrial Thermal Imager

FLK-LENS/TELE1
Telephoto Infrared Lens
(Ti32)

FLK/LENS/WIDE
Wide-angle Infrared Lens
(Ti32)

Ti-Car Charger
Car charger

FLK-TI-SPB3
Extra battery (Ti32)

FLK-TI-SBC3
Charging base (Ti32)

61

TiRx/TiR
Thermal Imagers
for Building Inspection
Optimized for energy audits, restoration and
remediation

Fluke TiR

The affordable rugged Fluke TiRx and TiR - Innovative protective lens cover
Thermal Imagers are workhorse tools
protects the lens when not in use
for the demands of building envelope,
• Enhanced problem detection and
restoration and remediation, inspection
analysis capabilities with patent pending
and roofing applications. Whether
IR-Fusion® Technology (TiR)
• Intuitive, three-button menu is easy to
to perform energy audits, locate the
use ... simply navigate with the push of a
origins of construction problem or to
thumb
find roof leaks, the TiRx and TiR offer
• Store more than 3.000 screen images
an economical solution for complete
(.bmp format) or 1.200 fully radiometric
detection, analysis and documentation.
images (.IS2 format) on included 2 GB SD
memory card
• Delivers the clear images to find
problems fast with its 160x120 sensor • The Fluke TiRx can be upgraded to a full
Fluke TiR with IR-Fusion at a later time.
• Even the smallest details become
visible with the large, widescreen full
color LCD display
• Optimized for field use in harsh work
environments
- Engineered and tested to withstand
a 2 meter drop
- Withstands dust and water – tested
to an IP54 rating

Specifications
(Check the Fluke web for detailed specifications)

New
Fluke TiRx

Complete package

Fluke TiRx
Thermal imaging performance
Detector type
Field of view (FOV)
Spatial resolution (IFOV)
Min focus distance
Thermal sensitivity (NETD)
Minimum span (Auto/Manual)
Focus
Visual imaging performance
Min focus distance
On camera operating modes
Visible light camera
Temperature measurement
Temperature range
Accuracy
Measurement modes
Image presentation
Digital display
LCD backlight
Palettes
Image and data storage
Storage medium
File formats supported
Controls and adjustments
Set-up controls
Language selection
Image controls
Power
Battery type
Battery operating time

Fluke TiR

160 x 120 Focal Plane Array, uncooled microbolometer
23 º horizontal x 17 º vertical
2.5 mrad
15 cm
≤0.1 °C at 30 °C (100 mK)
2.5 ˚C / 5 ˚C
Manual
46 cm
Picture-in-Picture and full screen IR
1.3 MegaPixel
-20 ˚C to 100 ˚C
± 5 °C or 5%
Center point
9.1 cm (3.6”) landscape color VGA (640x480) LCD
Selectable bright or auto
Ironbow, blue-red, high contrast, grey
2GB SD Card (3000 .bmp IR images/1200 .IS2 images)
JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Date/time, ˚C/˚F, language
Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Smooth auto scaling and manual scaling
Internal rechargeable battery NiMh (included)
3 to 4 hours continuous operation

Included Accessories
SmartView® software
2 GB SD card
SD card reader
Rugged hard carrying case
Soft carrying case
Hand strap
Rechargeable battery
AC charger/power supply
User manual
Training DVD

Water and dust resistant: IP54
Size (HxWxD): 267 x 127 x 152 mm
Weight: 1.2 kg
Two Years Warranty

Recommended Accessories

Ordering Information
62

Fluke TiRx
Fluke TiR

Inspector Thermal Imager
Thermal Imager

Ti-Visor
Sun Visor
(for complete Ti Series)

Ti-Car Charger
Car charger

Ti-TRIPOD
Tripod Mounting Base
Accessories
(for complete Ti Series)

TiR1/TiR32
Thermal Imagers
for Building Diagnostics
New

The top professional’s choice
The TiR1 and TiR32 Thermal Imagers are
the top professional’s choice for building
diagnostics. With its 320 x 240 sensor,
the TiR32 delivers the clear, crisp images
needed to find problems fast. The Fluke
TiR1 and TiR32 have all the features
of the Fluke TiR, but with an NETD of
0.07ºC for the TiR1 and 0.05ºC for the

TiR32 to identify even small temperature
differences that could indicate problems.
For added versatility and special
applications, the TiR32 includes dewpoint
measurements and two field-swappable,
rechargeable batteries. Use the optional
telephoto and wide-angle lens to bring
distant and wide views into sharp focus.

Fluke TiR32

Specifications
(Check the Fluke web for detailed specifications)
Fluke TiR1
Thermal imaging performance
Detector type

Fluke TiR1

Field of view (FOV)
Spatial resolution (IFOV)
Min focus distance
Thermal sensitivity (NETD)
Minimum span (Auto/Manual)
Focus
Optional lenses
Telephoto infrared lens type
Wide-angle infrared lens type
Visual imaging performance
Min focus distance
On camera operating modes
Color Alarm
Visible light camera
Temperature measurement
Temperature range
Accuracy
Measurement modes
Image presentation
Digital display
LCD backlight
Palettes

O
O
46 cm
Picture-in-Picture and full screen IR plus Blending
Dewpoint alarm
1.3 MegaPixel
2.0 MegaPixel
-20 ˚C to 100 ˚C

-20 ˚C to 150 ˚C
± 2 °C or 2%
Center point and hot and cold markers

9.1 cm (3.6") landscape color VGA (640x480) LCD
Selectable bright or auto
Ironbow, Blue-Red, High Contrast, Amber, Hot
Ironbow, Blue-Red, High Contrast, Amber,
Metal, Grey
Amber Inverted, Hot Metal, Grayscale,
Grayscale Inverted

Palettes Ultra Contrast
Voice Annotation
Voice annotation
Image and data storage
Storage medium
File formats supported
Controls and adjustments

O
O

Complete package

Battery operating time

O

2GB SD Card (3000 .bmp IR images/1200 .IS2 IR-Fusion images)
JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Date/time, Cº/ºF, language
On screen emissivity correction
On-screen reflected background temperature compensation
On-screen transmission correction
Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Smooth auto scaling and manual scaling

Set-up controls
Language selection
Image controls
Power
Battery type

Fluke TiR32

160 x 120 Focal Plane Array, uncooled
320 x 240 Focal Plane Array, uncooled
microbolometer
microbolometer
23 º horizontal x 17 º vertical
2.5 mrad
1.25 mrad
15 cm
≤0.07 °C at 30 °C (70 mK)
≤0.05 °C at 30 °C (50 mK)
2.5 ˚C / 3 ˚C
Manual

Internal rechargeable battery NiMh (included)
3 to 4 hours continuous operation

Two replaceable rechargeable battery packs
(Lithium ion)
4+ hours per battery pack

Included Accessories
SmartView® software
2 GB SD card
SD card reader
Rugged hard carrying case
Soft carrying case
Hand strap
Rechargeable battery
AC charger/power supply
User manual
Training DVD

Water and dust resistant: IP54
Size (HxWxD): TiR1: 267 x 127 x 152 mm
TiR32: 277 x 122 x 170 mm
Weight: TiR1: 1.2 kg
TiR32: 1.05 kg
Two Years Warranty

Recommended Accessories

Ordering Information
Fluke TiR1

Thermal Imager for Building
Diagnostics
Fluke TiR32 Thermal Imager for Building
Diagnostics

FLK-LENS/TELE1
Telephoto Infrared Lens
(Ti32)

FLK/LENS/WIDE
Wide-angle Infrared Lens
(Ti32)

Ti-Car Charger
Car charger

FLK-TI-SPB3
Extra battery (Ti32)

FLK-TI-SBC3
Charging base (Ti32)

63

Laser Distance Meters
The Fluke Laser Distance Meters bring you the most advanced
measuring technology. Unlike ultrasonic distance meters with laser
pointers, these meters use a precision narrow laser beam that can
avoid the common errors caused by extraneous objects near
measurement targets.

64

421D, 416D, 411D
Laser Distance Meters
New

Professional-grade laser distance
measuring tools that are fast, easy to use,
and fit in your pocket.
The Fluke laser distance meters bring you
the most advanced measuring technology.
These meters are fast, accurate, durable, and
easy to use — just point and shoot. Their
straightforward design and easy, one-button
operation mean you spend less time
measuring. Unlike ultrasonic distance meters
with laser pointers, the Fluke 421D, 416D
and 411D use a precision narrow laser beam
that can avoid the common errors caused by
extraneous objects near measurement
targets.

These compact and handy Fluke distance
meters are designed for indoor, and limited
outdoor applications. Addition, subtraction,
area, and volume calculations could not be
simpler. The extra bright laser is clearly
visible so you can see your targeting point
even if an object is hard-to-reach or distant.
The Fluke 421D, 416D and 411D have a large
LCD screen and buttons positioned for onehanded measurements.

Features

Fluke 421D
411D

416D

421D

Reduction of estimation errors, saving both time and money

O

O

O

Instant measurement with one-button operation

O

O

O

Easy targeting with bright laser

O

O

O

Quick calculation of area (square footage) and volume

O

O

O

Easy addition and subtraction of measurements

O

O

O

Improved battery life from automatic shut-off feature

O

O

O

Pythagoras calculation for determining distance indirectly from two other
measurements

O

O

O

Pouch

O

O

O

O

O

30 m

60 m

100 m

-

Ability to view more with large, 3-line display with backlight
Ability to measure up to
Storage capacity of measurements for quick recall of distance

Fluke 411D

Fluke 416D

10

20

MIN/MAX function

O

O

Enhanced Pythagoras calculation for determining distance indirectly from
three other measurements

O

O

Audible feedback of on and off modes

O

O

Strong environment protection with IP54 (water spray & dust proof) sealing

O

O

Audible feedback for taking room angle and incremental measurements

O

± 45° Tilt sensor for taking indirect measurements in hard to reach areas

O

Tripod mode allows you to mount to a tripod for measuring long distances

O

Built in light sensor for activating the backlight saving battery life

O

Corner angle feature, allows you to determine the angle of a corner

O

Specifications
(Check the Fluke web for detailed specifications)

Range (for extended distances, use a target plate)
Accuracy

411D/62 Kit
Combo kit includes:
- Fluke 62 Mini IR Thermometer
- Fluke 411D Laser Distance Meter
- Soft pouch for each model

Included Accessories
Two AAA batteries, Users manual on CD,
Quick start guide, Nylon carrying case,
Wrist wrap (421D)

Measurement units

Fluke 411D

Fluke 416D

30 m

60 m

100 m

± 3 mm

± 1.5 mm

± 1.5 mm

00.000 m

Measurement storage
Backlight
Automatic power off

Operating temperature: 0°C to 40°C
Storage temperature: -25°C to 70°C
Operating altitude: up to 3500 m
Battery Life: 411D: up to 3000 readings
416D, 421D: up to 5000 readings

After 180 seconds

Fluke 421D

00.000 m

00.000 m

10 locations

20 locations

O

O

After 180 seconds

After 360 seconds

Size (HxWxD): 411D: 123 mm x 50 mm x 26 mm
416D: 135 mm x 46 mm x 31 mm
421D: 127 mm x 52 mm x 25 mm
Weight:
411D: 0.150 kg
416D: 0.110 kg
421D: 0.125 kg
Warranty: 2 years

Ordering Information
Fluke 411D
Fluke 416D
Fluke 421D

Laser Distance Meter
Laser Distance Meter
Laser Distance Meter

65

Indoor Air Quality Tools
In response to the growing importance of air quality in buildings,
workplaces and homes, Fluke offers you a range of tools that monitor
temperature, humidity, air velocity, particulate, and carbon monoxide
levels. These tools help you to quickly and easily troubleshoot and
maintain indoor air quality, as well as to verify the efficient operation of
heating, ventilation and air conditioning systems.

66

975 AirMeter
Combined inspection tool for complete air
quality inspections
The Fluke 975 AirMeter combines five air
monitoring tools into one, rugged and
easy-to-use handheld tool. Use the Fluke
975 to verify the efficient operation of
heating, ventilation and air conditioning
systems, and test for dangerous carbon
monoxide leaks in all types of buildings.

• Simultaneously measures, logs, and
displays temperature, humidity, CO2,
and CO on a bright, backlit LCD display
• One-touch air flow and velocity
measurements with available probe
• Min/Max/Average on all measured and
calculated readings
• Audible and visual threshold alarms
• Multi-language user interface
• Extensive discrete or continuous data
logging capacity, down-loadable to PC
via USB interface

Specifications
(Check the Fluke web for detailed specifications)
Feature
Measured specifications
Temperature

Range

Display resolution

Accuracy

-20 °C to 60 °C

0.1 °C

10 % to 90 % RH noncondensing
50 fpm to 3000 fpm
0.25 m/sec to 15 m/sec

1 fpm
0.005m/sec

CO2

0 to 5000 ppm

1 ppm

CO

0 to 500 ppm

1 ppm

± 0.9 °C from 40 °C to 60 °C
± 0.5 °C from 5 °C to 40 °C
± 1.1 °C from -20 °C to 5 °C
± 2 % RH (10 % RH
to 90 % RH)
4 % or 4 fpm*
3 % or 0.015 m/sec*
whichever is greater
*Accuracy specification only valid
for velocity readings above 50 fpm.
Warm up time 1 min
(5 minutes for full specification)
2.75 % + 75 ppm
± 5 % or ± 3 ppm,
whichever is greater,
@ 20 °C and 50 % RH

Calculated specifications
Dew point temperature

-44 °C to 57 °C

0.1 °C

Wet bulb temperature

-16 °C to 57 °C

0.1 °C

0 to 3,965 M3/m 0 to
140,000 cfm)

0.001 M3/min (1 cfm)

0 to 100 %
0 to 100 %

0.1 %
0.1 %

Relative humidity
Air velocity

1%

Fluke 975

Volume flow rate (in a duct)

% outside air (based on temperature)
% outside air (based on CO2)

Operating temperature
(CO and CO2 sensors): -20 °C to 50 °C
Operating temperature
(all other functions): -20 °C to 60 °C
Storage temperature: -20 °C to 60 °C
Humidity: 10% to 90%
Altitude: Up to 2000 m

Included Accessories

± 1 °C when temp: -20 °C to 60 °C
RH: 40 % to 90 %
± 2 °C when temp: -20 °C to 60 °C
RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
± 1.2 °C when RH: 20 % to 90 %
temp: -20 °C to 60 °C
± 2.1 °C when RH: 10 % to 20 %
N/A: The volume flow
calculation will be a simple average
of the data points times the
duct area
N/A
N/A

Shock and vibration: MIL-PRF-28800F, Class 2
Battery: Rechargeable Li-Ion (primary), threeAA (backup)
Weight: 0.544 kg
Size (HxWxD): 28.7 cm x 11.43 cm x 5.08 cm
Data logging: 25,000 records (continuous),
99 records (discrete)
Multilanguage interface: English, French,
Spanish, Portuguese and German
Two-year warranty

A4 alkaline batteries (3), Users Manual,
Calibration Cap, FlukeView Forms Software,
Power Adapter, International Power Plugs,
Air Velocity Probe (Fluke 975V only)

Ordering Information
Fluke 975
Fluke 975V
975CK
975R
975VP

Recommended Accessories

AirMeter
AirMeter with Velocity
Airmeter Calibration Kit
Regulator
Air Velocity Probe
975VP
AirMeter Velocity Probe

67

922 Airflow Meter
Measures pressure, air flow and velocity for
maintaining balanced and comfortable
ventilation
The Fluke 922 makes airflow
measurements easy by combining
pressure, air flow, and velocity into a
single, rugged meter. Compatible with
most Pitot tubes, the Fluke 922 allows
technicians to conveniently enter
their duct shape and dimensions for
maximum measurement accuracy.

• Provides differential and static pressure,
air velocity and flow readings
• Convenient colored hoses help you
properly diagnose pressure readings
• Bright, backlit display for clear viewing
in all environments
• Min/Max/Average/Hold functions for
easy data analysis
• Auto power off saves battery life

Use the Fluke 922 to: Ensure proper air
flow balance and maintain a comfortable
environment; measure pressure drops
across filters and coils; match ventilation
to occupant loads; monitor indoor vs.
outdoor pressure relationships and
manage the building envelope; and
perform duct traversals for accurate
airflow readings.

Specifications
(Check the Fluke web for detailed specifications)
Feature

Range

Resolution

Accuracy

Operating Specifications

Air Pressure

Air Velocity
Fluke 922

Air Flow (Volume)

Temperature

± 4000 Pascals
± 16 in H2O
± 400 mm H2O
± 40 mbar
± 0.6 PSI
250 to 16,000 fpm
1 to 80 m/s
0 to 99,999 cfm
0 to 99,999 m3/hr
0 to 99,999 l/s
0 °C to 50 °C

1 Pascal
0.001 in H2O
0.1 mm H2O
0.01 mbar
0.0001 PSI
1 fpm
0.001 m/s
1 cfm
1 m3/hr
1 l/s
0.1°C

± 1% +1 Pascal
± 1% + 0.01 in H2O
± 1% + 0.1 mm H2O
± 1% +0.01 mbar
± 1% + 0.0001 PSI
± 2.5 % of reading at 10 m/s
(2000 p/min)
Accuracy is a function of
velocity and duct size
± 1 % + 2 °C

General Specifications
General specifications
Operating Temperature
Storage Temperature
Operating Relative Humidity

IP Rating
Operating Altitude
Storage Altitude
EMI, RFI, EMC
Vibration
Max Pressure at Each Port

Included Accessories
Fluke 922: Two Rubber Hoses, Wrist Strap, Four
AA Batteries 1.5 V Alkaline, Users Manual and
Soft Carrying Case
Fluke 922 Kit Includes: Fluke 922 Airflow Meter,
30.48 cm Pitot tube, ToolPak, Two Rubber
Hoses, Wrist Strap, Four AA Batteries 1.5 V
Alkaline, Users Manual and Hard Carrying
Case

Ordering Information
Fluke 922
Fluke 922/Kit

0 ºC to +50 ºC
-40 ºC to +60 ºC
Non condensing (<10 ºC)
90% RH (10 ºC to 30 ºC)
75% RH (30 ºC to 40 ºC)
45% RH (40 ºC to 50 ºC) Without Condensation
IP40
2000 m
12000 m
Meets requirements for EN61326-1
MIL-PREF-28800F, Class 3
10 PSI

Data Storage: 99 readings
Size (HxWxD): 175 x 775 x 419 mm
Weight: 0.64 kg
Battery: Four AA batteries
Battery Life: 375 hours without backlight,
80 hours with backlight
Two Year Warranty

Fluke 922/Kit

Recommended Accessories

Air Flow Meter
Airflow Meter with
30.48 cm Pitot Tube
PT12
Pitot Tube, 30.48 cm

68

TPAK
Toolpak
See page 120

971 Temperature Humidity Meter
Carbon Monoxide Meters
Fluke 971
Temperature Humidity Meter
Quickly take accurate humidity and
temperature readings in the air.
Temperature and humidity are two
important factors in maintaining
optimal comfort levels and good indoor
air quality. The Fluke 971 is invaluable
for facility maintenance and utility
technicians, HVAC-service contractors,
and specialists who assess indoor air
quality (IAQ). Lightweight, rugged, and
easy to hold, the Fluke 971 is the perfect
tool for monitoring problem areas.

• Simultaneously measures humidity and
temperature
• Measures dew point and wet bulb
• 99 record storage capacity
• Min/Max/Avg Data Hold
• Ergonomic design with built-in belt clip
and protective holster
• Backlit, dual readings display
• Twist-open protective cap
• Low battery indicator

Specifications

Fluke 971

Other useful tools

Fluke 561

Fluke 416D

Combined Contact
and Non-contact
Thermometer
See page 54.

Laser Distance Meter
See page 65.

Temperature range
Temperature accuracy
0 ºC to 45 ºC
-20 ºC to 0 ºC and 45 ºC to 60 ºC
Resolution
Response time (temperature)
Temperature sensor type
Relative humidity range
Relative humidity accuracy
10% to 90% R.H. @ 23 ºC
<10%, >90% R.H. @ 23 ºC
Humidity sensor
Data storage
Response time (humidity)

-20 ºC to 60 ºC
± 0.5 0C
± 1.0 ºC
0.1 ºC
500 ms
NTC
5% to 95% R.H.
± 2.5 % R.H.
± 5.0 % R.H.
Electronic capacitance polymer film sensor
99 points
For 90% of total range - 60 sec with 1 m/s air movement

Operating temperature:
Temperature: -20 °C to 60 °C
Humidity: 0 °C to 60 °C
Storage temperature: : -20 °C to 55 °C
Battery life: 4 AAA alkaline, 200 hours

Safety: Complies with EN61326-1
Weight: 0.188 kg
Size (HxWxD): 194 mm x 60 mm x 34 mm
One Year Warranty

Carbon Monoxide Meters
CO-220 Carbon Monoxide Meter

Included Accessories
Fluke CO-220:

C50 soft carrying case and
battery

The CO-220 Carbon Monoxide Meter makes it easy to take quick
and accurate measurements of CO levels. A large, backlit LCD
display shows CO levels from 0 to 1000 PPM. The MAX Hold
function stores and displays the maximum CO level.
1 year warranty.

Fluke CO-220

Ordering Information
Fluke 971
Fluke CO-220
CO-205

Temperature Humidity
Meter
Carbon Monoxide Meter
Aspirator Kit

CO-205 Aspirator Kit
Allows flue gas samples up to 371°C to be drawn with the
CO-220 for carbon monoxide measurement.
1 year warranty.

Fluke CO-205

69

983 Particle Counter /
RLD2 Leak Detector Flashlight
Easy to use tool for troubleshooting and
maintaining indoor air quality
The Fluke 983 Particle Counter
simultaneously measures and displays
six channels of particle size distribution,
temperature and humidity. This compact,
lightweight, self-contained tool allows
for one-handed operation. As the Fluke
983 doesn’t require level holding, it can
make accurate measurements in any
position. The 8 hour rechargeable battery
together with a large 5000 sample record
allows for complete air quality surveys in
one go. The Fluke 983 is the ideal tool for
determining size distribution of airborne
particles or tracking down a particle
source.

• Simultaneously measure and display 6
channels of particle sizes, temperature
and humidity
• Measure particle size down to 0.3 μm
• Selectable sample time, count data,
programmable delay
• Store 5000 records of date, time, counts,
relative humidity, temperature, sample
volumes, alarms and location label
• Upload stored data to a PC with
included software
• Compact, self-contained package allows
for one-handed operation
• Intuitive, easy-to-use user interface
• Always ready to run, with no fluids to
refill
• Backlit LCD for use in any lighting
condition

Specifications

Fluke 983

6 size channels
Flow rate
Count modes
Counting efficiency
Zero count
Coincidence loss
Relative humidity
Temperature
Data storage
Alarms
Delay time
Sample inlet
Interface
Calibration

0.3, 0.5, 1.0, 2.0, 5.0, 10.0 μm
0.1 cfm (2.83 L/min) controlled by internal pump
Concentration, totalize, audio
50 % @ 0.3 μm; 100 % for particles > 0.45 μm (per JIS B9921:1997)
1 count/5 minute (per JIS B9921:1997)
5 % at 56,000 particles per m3
± 7 %, 20 % to 90 %, non-condensing
± 3 °C, 10 °C to 40 °C
5000 sample records (rotating buffer) of date, time, counts, relative humidity,
temperature, sample volumes, alarms, label
Counts, low battery, sensor fail
0 to 24 hours
Isokinetic probe
RS-232 and RS-485 via RJ-45
PSL particles in air (NIST traceable)

Operating temperature: 10 °C to 40 °C, 20 % to
90 % relative humidity, non-condensing
Storage temperature: -10 °C to 50 °C, up to
90 % relative humidity, non-condensing
Power: AC adapter, 90 to 250 V AC, 50 to 60 Hz
Battery life/recharge time: 8 hours/2 hours

RLD2 Leak Detector Flashlight

Included Accessories
Fluke 983:
Certificate of Calibration (NIST)
Isokinetic probe
Zero count filter
Windows-compatible software download
utility
DB9 to RS-232 adapter and cable
High purity tubing
1/8 in. hose barb adapter
Power supply
Operation manual
Hard molded carrying case
Fluke RLD2: Key chain carabiner and batteries.

Ordering Information
Fluke 983
Particle Counter
Fluke RLD2 Leak Detector Flashlight

70

Rechargeable battery: NiMH, 4.8V at 4.5 Ah;
replaceable
Size (HxWxD): 209 mm x 114 mm x 57 mm
Weight: 1 kg
Warranty: 1 year

New

RLD2 Leak Detector Flashlight.
Leak detection made easy. The compact RLD2
uncovers refrigerant leaks instantly. Use the UV
light to find the leakage area, then, use the laser
pointer to pinpoint the exact leak location.
• Six UV LEDs detect leak detection dyes
• Laser pointer clearly locates center of the UV
field for accuracy
• Three LED flashlight with 100,000 hour LED life
• Operating temperature 0ºC to 50ºC
• Four operating modes: flashlight, UV light, laser
light, UV/laser light combination
• One year warranty

ScopeMeter® Test Tools
With the original ScopeMeter, we transformed the oscilloscope category
beyond recognition, and we still lead the way today. From rugged
solutions for industrial applications to full-colour models that pack topend bench oscilloscope specifications into hand-held, battery powered
instruments. In short, ScopeMeter provides you with unmatched speed,
performance and analysis power while working on site.

71

ScopeMeter® Test Tools
Oscilloscopes for field applications
Features
225C

215C

LDC Display
Persistence

O
O
O
O
O
O
O
O

Waveform reference
Automatic pass fail testing
Cursors and zoom
Connect and View triggering
Video triggering with line selector
Selectable pulse width triggering
Capture and replay of last 100 screens

O
O
O
O
O
O
O
O

Dual input TrendPlot

The ScopeMeter 190C Series of high
performance oscilloscopes have
bandwidth of 60, 100 and 200 MHz and
sample rates up to 2.5 GS/s.
These instruments offer a highresolution color display that has a
fast update rate, waveform pass/fail
testing and a digital persistence mode
– making the analysis of complex and
dynamic signals much easier.
For industrial electronic or electro
mechanical applications, the 120 Series
Industrial ScopeMeter, with a 20 or
40 MHz bandwidth and Connect-andView™ triggering for an instant, stable
display will get the job done.

199C

196C

192C

125

124

Color

123

B/W

O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O

Cursors

O
O

O
O

O
O

With cursors and Zoom

O

O

O

Memory for screens and set-ups

10 screens and setup

20

20

10

Recorder memories, each can store 100 scope screens,
a ScopeRecord or a TrendPlot

2 recorder memories

O

O

O

O/O

O/O

1000V Independently floating isolated outputs
Meter measurements: VAC RMS, VAC+DC, Ohms,
Continuity, Diode, Amps, Temp. (ºC, ºF)
Waveform mathematics: A+B, A-B, AxB, A versus B
(X-Y mode)
Frequency Spectrum Analysis using FFT
Power measurements and VPWM
Capacitance and frequency measurements
Bus Health Test function
Rugged, dust and drip proof case (IP51)
PC and printer interface via optically isolated RS232/USB cable
FlukeView® for Windows® Software (SW90W)

OStandard equipped

1) Optional

O
O

O
O

O
O

O
O

O
O

O

O

O

O

O

O
O
-/O
O
O

O
O
-/O
O
O

O
O
-/O

O
O
-/O

O
O
-/O

O

O

O

O
O/O
O
O

O

O

1)

1)

1)

1)

1)

1)

1)

1)

1)

1)

1)

1)

1)

1)

1)

1)

2)

2) Harmonics mode

Specifications
(Check the Fluke web for detailed specifications)
225C

215C

199C

196C

192C

Bandwidth

200 MHz

100 MHz

200 MHz

100 MHz

60 MHz

Max. real time sample rate

2.5 GS/s

1 GS/s

2.5 GS/s

1 GS/s

500
MS/s

125

124

123

Oscilloscope specifications

Input sensitivity

2 mV/div. ...1000 V/div

Timebase range

5 ns/div. ...2 min/div.

Inputs and digitizers

40 MHz

20 MHz

25 MS/s
5 mV/div. ...500 V/div.

10 ns/div.
...2 min/
div.

10 ns/div. ...1min/div.

2 plus external trigger/DMM input

Independently floating isolated outputs
Max. record length...
... in Scope mode:
... in ScopeRecorde mode:
Glitch capture

20
ns/div. ...1
min/div.

2

Up to 1000 V between inputs, references and ground
3000 points per input
27.500 points per input or more (5 ms/div. to
2 min/div.)
Up to 3 ns using Pulse Width triggering;
50 ns peak detect at 5 μs/div. to 1 min/div.

Scope measurements

512 min/max points per input

40 ns
cursors + 26 automatic

7 cursor measurements, 30 automatic measurements
Automatic Vrms and watts measurement on cursor
limited part of waveform

True RMS multimeter

5000 counts, single input

26
automatic
...plus
power
measurements and
Vpwm
5000 counts, dual input

General specifications
Line power

Adapter/battery charger included (BC190)

Battery (installed)
Size
Weight
Safety certified (EN61010-1)
Warranty

72

>3,5 hr Ni-MH (BP190)

Adapter/battery charger included
(PM8907)
7 hr Ni-MH (BP120 MH)

256 x 169 x 64 mm

232 x 115 x 50 mm

2 kg

1.2 kg

1000 V CAT II / 600 V CAT III

600 V CAT III

3 years on main products and 1 year on accessories

Check the Fluke web site for Technical Specifications and
Application Notes for the Fluke ScopeMeters

ScopeMeter® 120 Series
Three-in-one simplicity
The compact ScopeMeter 120 Series
is the rugged solution for industrial
troubleshooting and installation
applications. It’s a truly integrated test
tool, with oscilloscope, multimeter and
“paperless” recorder in one affordable,
easy-to-use instrument. Find answers to
problems in machinery, instrumentation,
control and power systems quickly and
easily.

Fluke 125

Fluke 124

• Dual-input 40 MHz or 20 MHz digital
oscilloscope
• Two 5,000 counts true-RMS digital
multimeters
• A dual-input TrendPlot™ recorder
• Bus Health Test for industrial bus
systems (Fluke 125)
• Connect-and-View™ trigger simplicity
for hands-off operation
• Power Measurements and Harmonics
measurement (Fluke 125)
• Shielded test leads for oscilloscope,
resistance and continuity
measurements
• Up to 7 hours battery operation
• 600 V CAT III safety certified
• Optically isolated interface for PC and
Printer connection (optional)
• Rugged, compact case

Connect-and-View™ triggering for
an instant, stable display

Fluke 123

True RMS

stable, reliable and repeatable display
of virtually any signal - including
motordrive and control signals - without
touching a button. Signal changes
are instantly recognized and settings
adjusted for - once again - a stable
display.

Use TrendPlot™ to help find
intermittents fast
The toughest faults to find are those
that happen only once in a while:
intermittents. They can be caused by
bad connections, dust, dirt, corrosion
or simply broken wiring or connectors.
You may not be around to see it – your
Fluke ScopeMeter will. In this “paperless
recorder” mode,
you can plot the minimum and
maximum peak values and average over
time – up to 22 days (Fluke 190 Series) or
16 days (Fluke 120 Series).

Bus Health mode (Fluke 125)
Bus Health mode gives a clear “Good/
Bad” indication for the electrical signals
on industrial buses and networks, such
as CAN-bus, Profi-bus, RS-232 and many
more. The Fluke 125 validates the quality
of the electrical signals as soon as any
electrical signals are passed along the
network.

Scope users know how difficult triggering
can be. Wrong settings show unstable
and sometimes wrong results. Fluke’s
unique Connect-and-View recognizes
signal patterns, and automatically
sets up correct triggering. It provides a

Included Accessories
PM 8907 line adapter/charger, STL120 shielded
test leads set (1 red, 1 grey), AC120 Alligator
Clips, BB120 shielded BNC adapter, BP120MH
NiMH battery pack, VPS40 wide bandwidth
Voltage Probe (Fluke 124/125), TL75 hard
point test lead, i400s current clamp (Fluke
125), Getting Started booklet, user’s manual
(cd-rom)

Ordering Information
Fluke 123
Industrial ScopeMeter® (20MHz)
Fluke 123/S Industrial ScopeMeter® (20MHz)
+ SCC120 kit
Fluke 124
Industrial ScopeMeter® (40MHz)
Fluke 124/S Industrial ScopeMeter® (40MHz)
+ SCC120 kit
Fluke 125
Industrial ScopeMeter (40 MHz)
Fluke 125/S Industrial ScopeMeter (40 MHz) +
SCC120 kit
SCC120
FlukeView® Software + OC4USB
Cable + Carrying Case
OC4USB
USB Interface Cable
PM9080
RS-232 Interface Cable
DP120
Differential Voltage Probe
ITP120
Isolated Trigger Probe
SW90W
FlukeView Software
BHT190
Set of 3 break-out adapters
(Fluke 125)

Connect-and-View captures even the most
complex motor drive signals.

Bus Health mode allows for an analysis of the
signal quality on an industrial network.

See page 72 for specifications.

Recommended Accessories

SCC120

C125
See page 118

DP120
See page 76

OC4USB
See page 76

SCC128
See page 113

73

ScopeMeter® 190C Series
(incl. 225C and 215C)
Speed, performance and analysis power
For more demanding applications, the
ScopeMeter 190C Series high performance
oscilloscopes offer specifications usually
found on top-end bench instruments.
With up to 200 MHz bandwidth, 2.5 GS/s
real-time sampling and a deep memory of
27500 points per input they’re ideal for
engineers who need the full capabilities
of a high performance oscilloscope in a
handheld, battery powered instrument.

Fluke 199C

Fluke 196C

Fluke 192C

• Dual input – 60, 100 or 200 MHz models
• Up to 2.5 GS/s real time sampling per input
• Bus Health Test capability for industrial
buses, including Profi, Foundation, ModBus
and many more (225C and 215C)
• High resolution color display
• High waveform resolution of max. 3000
datapoints per channel
• Digital Persistence for analyzing complex
dynamic waveforms like on an analog
scope
• Fast display update rate (> 100/sec) for
seeing dynamic behavior instantaneously
• Connect&View™ automatic triggering,
a full range of manual triggering modes
plus external triggering.
• Automatic capture and replay of
100 screens
• 27500 points per input record length using
ScopeRecord mode
• Up to 1000 V independently floating
isolated inputs
• Waveform reference for visual
comparisons and automatic pass/fail
testing of waveforms
• Vpwm function for motor drive and
frequency inverter applications.
• Waveform mathematics: Add, Subtract and
Multiply
• Frequency Spectrum Analysis using FFT
• X-vs-Y mode (Lissajous display) for study
of signal relationships
• Cursors, zoom and real-time clock
• 30 automatic waveform measurements
• Over 3.5 hours rechargeable Ni-MH battery
pack
• Includes a 5000 count true-RMS
multimeter and a TrendPlot™ paperless
recorder

ScopeMeter for medical imaging and
video test applications
Fluke 225C

Fluke 215C

True RMS
On all inputs

74

For tests on such systems, an optional
configuration is available. Please check the
Fluke website for further details.

Bus Health Test (225C and 215C)
Bus Health Test analyses the electrical
signals on an industrial bus or network
and gives a clear “Good”, “Weak” or “Bad”
validation mark for each of the relevant
parameters, presented next to the actual
measurement value.
The Fluke 225C and 215C can make the
signal quality validation as soon as electrical
signals are passed along the network,
without looking at the data content. They
find errors like improper cable connections,
bad contacts, incorrect grounding and
missing or superfluous terminators.

Automatic capture and replay
of 100 screens
Scope users know how frustrating it is to
see a one time anomaly flash by, never to be
seen again. Not with the ScopeMeter 190C
Series! Now you can look back in time with
a touch of the replay button. In normal use,
the instrument continuously memorizes
the last 100 screens. Each time a new
screen is acquired, the oldest is discarded.
At any moment you can “freeze” the last
100 screens and scroll through pictureby-picture or replay as a ‘live’ animation.
Cursors can be used for further analysis.
You can even use the advanced trigger
capabilities to capture up to 100 specific
events. Two sets of 100 captured screens
with individual time stamps can be stored
for later recall or download to a PC.

ScopeMeter® 190C Series
(incl. 225C and 215C)
See dynamic signal
behavior instantaneously

Frequency Spectrum Analysis 190C

The Digital Persistence mode helps to find
anomalies and to analyze complex dynamic
signals by showing the waveforms amplitude
distribution over time using multiple
intensity levels and user selectable decay
time - it’s as if you’re looking at the display
of an analog, real time oscilloscope! A fast
display update rate reveals signal changes
instantaneously, useful for instance when
making adjustments to a system under test.

All 190C Color ScopeMeters include
Frequency Spectrum Analysis on Fast Fourier
Transformation (FFT) analysis as a standard
feature.
This makes it possible to identify the
individual frequency components contained
in a signal. The spectrum analysis function is
also handy to reveal the effects of vibration,
signal interference or crosstalk. An automatic
window function assures optimal windowing,
although you may manually select your
preferred time window.

Pulse width fluctuations are clearly visible using Digital
Persistence

Frequency Spectrum shows an overview of frequencies
contained in a signal.

FlukeView® Software for documenting,
archiving and analysis
FlukeView® for Windows® helps you get more
out of your ScopeMeter by:
• Documenting - transfer waveforms,
screens and measurement data from the
ScopeMeter to a PC. Print or import the data
into your report
• Archiving - create a library of waveforms
with your comments for easy reference and
comparison
• Analysis - use cursors, perform spectrum
analysis or export data to other analysis
programs

FlukeView Screen

Included Accessories
BC190 Battery Charger
BHT190 Set of 3 break-out adapters
(225C/215C)
BP190 NiMH Battery Pack
VPS210-G + VPS210-R Voltage Probe
TL75 Hard Point Test Lead Set
user’s manual (CD-Rom), Getting Started
Booklet

Ordering Information
Fluke 192C
Fluke 196C
Fluke 199C
Fluke 215C
Fluke 225C
Fluke 192C/S
Fluke 196C/S
Fluke 199C/S
Fluke 215C/S
Fluke 225C/S
SCC190
SCC191
C190
SW90W

Color ScopeMeter
(60 MHz, 500 MS/s)
Color ScopeMeter
(100 MHz, 1 GS/s)
Color ScopeMeter
(200 MHz, 2.5 GS/s)
Color ScopeMeter with Bus
Health Test (100 MHz, 1 GS/s)
Color ScopeMeter with Bus
Health Test
(200 MHz, 2.5 GS/s)
192C + SCC191 kit option
196C + SCC191 kit option
199C + SCC191 kit option
215C + SCC191 kit option
225C + SCC191 kit option
SW90W FlukeView Software,
OC4USB cable, C190 briefcase
style carrying case
SW901W FlukeView Software,
OC4USB cable, industrial style
carrying case
Briefcase style carrying case
FlukeView Software

Thanks to the deep memory, very small parts of the waveform can be studied in full detail
using “zoom”.

See page 72 for specifications.

Recommended Accessories

ScopeMeter SCC191

Scopemeter SCC190

C195
See page 118

OC4USB
See page 76

SCC198
See page 113

75

ScopeMeter® Accessories
ScopeMeter probes

VPS40

Description
Number and color
Attenuation
Bandwidth DC-MHz
Length (m)
EN 61010-2 CAT II
EN 61010-2 CAT III
ScopeMeter 190 Series
ScopeMeter 120 Series

VPS210-R series

VPS40
Voltage
Probe Set
One Black
10:1
40
1.2
1000 V
600 V

VPS210-G series

VPS210-R
VPS210-G
Voltage Probe Set
1 Red

VPS212-R
VP212-G
Voltage Probe Set

1 Grey

1 Red

10:1
200 MHz
1.2 m
1000 V
600 V
O

1 Grey

VPS220-R
VPS220-G
Voltage Probe Set
1 Red

10:1
200 MHz
2.5 m
1000 V
600 V
O

O
O

O

PM8918/301

DP120

1 Grey
100:1
200 MHz
1.2 m
1000 V
600 V

O
O

O

O

VPS101
Voltage Probe
Set
1 Black
1:1
30 MHz
1.2 m
300 V
O

DP120
Differential
Probe Set
Red & Grey
200:1, 20:1
20
1.5
1000 V
600 V
O
O1)

PM8918/301
Low Pass
Filter Probe
One Blue
10:1
4 kHz
2.5
600 V
O
O1)

1) Using BB 120

PM9091/9092

Description
Length
EN 61010-2 CAT III
ScopeMeter 190 Series
ScopeMeter 120 Series

PM9081

PM9091
50 Ω BNC cable set
(1Red, 1Grey, 1Black)
1.5 m
300 V
O
O1)

PM9082

PM9092
50 Ω BNC cable set
(1Red, 1Grey, 1Black)
0.5 m
300 V
O
O1)

PM9093

PM9081
Dual Banana plug male to
female BNC

PM9082
Dual Banana jack female to
male BNC

PM9093
Male BNC to dual
female BNC

600 V
O
O

600 V
O
O1)

600 V
O
O1)

1) Using BB 120

RS200

RS200
AS200-R
AS200-G
PM9080
OC4USB
PM9090
PM9094
PAC91

76

AS200-R

Probe Accessory Replacement Set for VPS Series Probes
Probe Accessory Set, Red for VPS Series Probes
Probe Accessory Set, Grey for VPS Series Probes
Optical Interface Adapter Cable for serial port
Optical Interface Adapter Cable for USB Port
Probe Pin Grabber Flexible Clip for VPS Series Probes
Mini Testhook Set for PM8918 Probes
Printer Adapter Cable

OC4USB

PM9080

Battery Packs
BP120MH
BP190

PM9090

NiMH Battery Pack for 120 Series + 43B
NiMH Battery Pack for 190 + 430 Series

All accessories have a one year warranty

Power Quality Tools and Power
Analyzers
We offer an extensive range of power quality test tools for
troubleshooting, predictive maintenance and long-term recording in
industrial and utility applications. For the development and test of
electrical equipment, our high-precision power analyzers enable easy
and reliable use in the field or as a bench unit in test laboratories.

77

78

Detailed RMS trending shows how connected loads
behave.

RMS voltage
RMS Current
Energy studies
Measure V, I, kW, Cos/DPF, kWhr
Measure MIN/MAX and AVG values
10 day logging
Energy aggregation
Utility meter pulse input
Energy Loss (Eff. kW, Reactive kVAR, Unbalance
kVAR, Distortion kVAR, Neutral kVAR)
Basic harmonics study
THD measurement (V & I)
Harmonics 1 to 25 for V & I
Tabular values
Neutral current measurement
Crest factor
Advanced harmonics study
Full harmonic spectrum
Power harmonics
Harmonics 1 to 50 and dc
k-factor
%Fundamental and %RMS
Basic Industrial PQ Troubleshooting
Oscilloscope function
Voltage dips and swells
Phasor diagram
Trend recording
Inrush current
Advanced industrial PQ troubleshooting
Comprehensive logging capability
Transient capture
Flicker
EN50160 analysis
Complex System interaction event capture
(manual threshold setting)
Random/variable system event capture (Adaptive
threshold setting)
Utility PQ benchmarking
Phase sequence components
Interharmonics
Mains signaling
IEC61000-4-30 Class A
Software
PowerLog
PQLog
Power Analyze
PQ Analyze
FlukeView Forms

Go to www.fluke.co.uk/pq or www.fluke.eu/pq to see the video

Power Quality in Industrial Applications
Covers the basics of power quality and looks at the tools and inspection techniques
used to troubleshoot common problems.

VIDEO

O

O
O
O
O

O
O
O
O
O

O

O

O
O

O
O

O
O

O
O
O
O
O

O
O
O
O
O

O

O
O
O
O
O

430
O
O

To make use of the power data you collect, you need
software that can help analyze your findings and share
them with equipment providers and plant management.

O

O

O
O

O

O

O
O
O
O
O

O

O
O
O
O

O
O

O

O
O
O

O
O
O
O

43B
O
O

O
O
O
O

Single phase
345
O
O

O
O
O
O

O
O

O

O

O
O

VR1710
O

Before you install sensitive loads, make sure you
understand the existing quality of power delivered by
your utility. Comparing benchmarks over time can help
pinpoint potential areas of concern.

Complex installations often require a deeper dive into
measurement data. Multiple loads may be interacting
randomly to cause a single problem.

When troubleshooting in the field, graphical data
enables you to trace the source of the problem at hand.

If distorting loads are causing problems in your
installation, you need comprehensive data to intentify
the source and create a solution.

Discover the source of distortion in your installation, so
that you can filter those loads or move them to separate
circuits.

Get detailed power and energy consumption
profiles during energy audits and pinpoint savings
opportunities.

Application use

Basic measurements

Power quality tools help pinpoint problems fast

O

O
O

O

O

O
O
O
O

O

O
O
O
O

1735
O
O

O

O
O

O
O

O

O

O(no DC)

O

O
O
O
O
O

O

O
O
O
O

Three phase
1740
O
O(not 1743)

O

O
O
O

O

O
O
O
O

O
O
O
O
O

O
O
O
O
O

O
O
O
O
O

O

O
O
O
O

1750
O
O

O

O
O
O
O

O

O
O
O
O

O
O
O
O
O

O
O
O
O
O

O
O
O
O
O

O

O
O
O
O

1760
O
O

Power Quality Selection Guide

VR1710 Single-Phase Voltage
Quality Recorder
Easy-to-use solution for detecting and
recording voltage quality problems

Fluke VR1710

The Fluke VR1710 is a single-phase, plugin voltage quality recorder that provides
fast and easy recording of voltage trends,
dropouts, harmonics and general power
quality including dips and surges to help
maintenance and facilities management
personnel easily pinpoint the root cause
of voltage problems. Voltage quality
parameters including RMS average,
transients, flicker, and harmonics up to
the 32nd are recorded using a userselected average period from
1 second to 20 minutes.

• Clear graphical summary of data and
quick overview of key power quality
parameters
• Get the complete picture with Min, Max,
Average RMS values (1/4 cycle) with
time stamps
• See the detailed with actual transient
display (> 100 μs) with time stamp
• Comprehensive analysis of Individual
harmonic and THD values with trends

Applications
• Voltage recording – Monitors and
records supply voltage; measures RMS
average, minimum and maximum
values, and checks whether the socket
outlet is providing voltage within
tolerance.
• Distortion measurement – Measure
frequency and harmonics; check
whether the distorting loads (UPS
systems, drives, etc.) are affecting your
other equipment.

• Flicker measurement – Quantify the
affects of switching loads on lighting
systems.
• Voltage transients – Capture those
intermittent, momentary events that
may be affecting your equipment; the
full waveform is captured with date,
timestamp, and duration.

Fluke VR1710 and included accessories

PowerLog Setup – Simple set up of
internal clock, logging periods, and
intervals with default values for
quick results.
PowerLog View – Data presentation
showing RMS voltage and harmonic
trends, actual transients, summary
information and statistics in
accordance with EN50160.

Actual transient display
(> 100 μs) with time stamp–
Quickly identify issues with included
graphical software.

Statistical analysis of voltage event
– reduces analysis time by tracking
event quantities and magnitudes.

Specifications
(Check the Fluke web for detailed specifications)

Includes PowerLog software

Included Accessories
Plug-in Fluke VR1710, USB cable, PowerLog
software CD, universal power cord adapters.

Operating voltage
Min/Max/Avg RMS value
Number of events
Dips/Interruptions
Time resolution
Voltage resolution)
Over-voltages
Frequency
Harmonics measurement
Flicker measurement
Number of recording channels
Recording time
Transients
Frequency range
Safety category rating

70 V to 300 V
Resolution 0.125 V
175,000
Yes
5 ms
0.125 V
Yes
Yes
EN 61000-4-7 (up to 32nd)
EN 61000-4-15
1 Phase to Neutral
2 Phase/Neutral to Ground
1 day to 339 days depending on average time from 1 second to 20 minutes
Yes (> 100μs)
50 Hz ± 1 Hz and 60 Hz ± 1 Hz
CAT II 300 V

Ordering Information
Fluke VR1710

Voltage Quality Recorder

Display: LED
Size (HxWxD): 23 x 19.75 x 22.2 cm

Weight: 0.8 kg
Two years warranty

79

345
Power Quality Clamp Meter
The ideal troubleshooting tool for modern
electrical loads
The Fluke 345 measures a wide range of
electrical parameters for troubleshooting
power disturbances in single- and
three-phase electrical loads. With a
bright color display to see waveforms
and trends, a low-pass filter to remove
high frequency noise, and a high EMC
immunity design, the Fluke 345 is ideal
for measurements on switching loads
such as variable speed drives, electronic
lighting and UPS systems.

• High safety rating: 600V CAT IV / 1000V
CAT III rated for use at the service
entrance
• ac/dc current measurements: Clampon measurement of ac peak and dc
current up to 2000 A without breaking
the circuit
• Harmonic analysis: Analyze, display
and log harmonics up to the 30th
harmonic (40th harmonic for 15 Hz to
22 Hz)
• Verify batteries: Direct measurement
of dc ripple (%) for battery and dc
systems

Specifications
(Check the Fluke web for detailed specifications)

Fluke 345
Current measurement
DC, DC rms, AC rms

All measurements DC and 15 Hz to 1 kHz.
Maximum overload 10,000 A or RMS x frequency < 400,000. Amps rms is a true rms
measurement (AC + DC).
0 – 2000 A dc or 1400 AC rms
All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency
range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A

Measuring range
Harmonics

Voltage measurement
DC, DC rms, AC rms

All measurements DC and 15 Hz to 1 kHz. Maximum overload 1,000 V rms. Volts rms is a
true-rms measurement (AC + DC).
0 – 825 V DC or AC rms
All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz
to 65 Hz; Vacrms > 1V

Measuring range
Harmonics
Watts measurement (single- and three-phase)

Measuring range

View waveforms for equipment
checking and setup

VA measurement (single- and three-phase)

Measuring range

DC, DC rms, AC rms
0 – 1650 kW DC or 1200 kW ac
DC, DC rms, AC rms
0 -1650 kVA DC or 1200 kVA ac

VAR measurement (single- and three-phase)

Measuring range

0 – 1250 kVAR

Power factor (single- and three-phase)

Measuring range

0.3 cap…1.0… 0.3 ind (72.5° cap…0°… 72.5° ind)

Displacement power factor

Measuring range

0.3 cap … 1.0 … 0.3 ind (72.5° cap ... 0° ... 72.5° ind)

Kilowatt Hour (kWHr)

Measuring range

40,000 kWHr

Scope function

Time base
Current management:
Ranges
Voltage measurement:
Ranges

2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div
10 A/20 A/40 A/100 A; 200 A/400 A/1000 A/2000 A
4 V/10 V/20 V/40 V/100 V; 200 V/400 V/1000 V
All measurements dc and 15 Hz to 1 kHz
40, 400 and 2000 A
Up to 50 screen shots and over 150,000 individual measurement values

Inrush current function

Ranges

Log parameters over time
to track down intermittent faults

Memory

Power supply: 1.5 V Alkaline AA MN 1500 or IEC LR6
x 6 Battery
Battery life (typical): >10 hours (backlight on full);
>12 hours (backlight reduced)
Safety: IEC 61010-1 600 V CAT IV, 1000V CAT III
(maximum input phase-phase 825V rms) double or
reinforced insulation, pollution degree 2
Protection: IP40; EN60529
Operating temperature: 0 °C to 50 °C

Display: Color transmissive LCD 320 x 240 pixels
(70 mm diagonal) with 2 level backlight
Digital output: USB interface to a PC
Size (HxWxD): 300 mm x 98 mm x 52 mm
Jaw opening: 60 mm
Jaw capacity: 58 mm diameter
Weight (including batteries): 0.82 kg
Two Year Warranty

Included Accessories
Soft carrying case, Power Log software,
Test probes, Test leads, Alligator clips,
International ac adapter / battery eliminator,
Printed English User manual, Multi-language
manual on CD

Recommended Accessories

Ordering Information
Fluke 345

Power Quality Clamp Meter
TLK291
See page 111

80

TP220
See page 111

AC220
See page 112

TP1
See page 111

C550
See page 118

43B Single-phase Power
Quality Analyzer
The perfect tool for tracking down
single-phase power-related problems
The Fluke 43B is the choice for
diagnosing and troubleshooting power
quality and general equipment failures.
Ease to use thanks to menu selection of
the power modes, it combines the

capabilities of a power quality analyzer, a
20 MHz oscilloscope, a multimeter and a
data recorder in a single instrument.

• Voltage, current, and
power harmonics
• Up to 51st harmonic
• Total harmonic distortion
(THD)
• Phase angle of individual
harmonics

• Continuously measure
volts and amps on a
cycle-by-cycle basis for up
to 16 days
• Use cursors to read time
and date of sags and
swells

• Watts, power factor,
COS ij, VA and VAR
• Voltage and current
waveforms

• Connect-and-View™
scope for quick waveform
display
• View voltage and current
channels simultaneously

Fluke 43B

Specifications
(Check the Fluke web for detailed specifications)
Menu items
Volts/Amps/Hz

On all inputs
Power
Harmonics

True RMS
Sags & Swells
Transient Capture
Inrush Current
Ohms/Continuity/
Capacitance
Temperature
(with accessory)
Scope

Included Accessories
TL224 test lead set, AC220 alligator clip set,
TP4 test probe set, BP120MH rechargeable
battery pack, BB120 shielded BNC adapter,
PM8907 line adapter/charger, i400s AC current
clamp, AB200 alligator clip set,
TP1 test probe set, C120 hand carrying case,
OC4USB interface cable, SW43W FlukeView
software, VPS 40 voltage probe, Fluke 61 IR
thermometer, user and application manual.

Screen saves
Recording

Measurements
Volts
Amps
Mains frequency
CF Crest Factor
Watts, VAR, VA
PF, DPF, COS ij
Volts
Amps
Watts
K-factor
Voltage and Current
40 ns pulse width
Up to 40 transients
1 sec. to 5 min selectable
Ohms
Capacitance
ºC
ºF
DC, AC, AC+DC, peak,
peak-peak, Hz, duty cycle,
phase, pulse width,
crest factor
All functions
V/A/Hz, Power, Harmonics,
Ω/Cap, Temperature, Scope

Accuracy
±(1%+10)
±(1%+10)
±(0.5%+2)
±(5%+1)
±(4%+4)
±0.04
±0.03
±(3%+2) to ±(15%+5)
±(3%+8) to ±(15%+5)
±(5%+2) to ±(30%+5)
±10%
±(2%+10)
± 5% of full scale
± 5% of full scale
± (0.6%+5)
± (2%+10)
± (0.5%+5)
25 MS/sec
20 MHz
15 kHz
Select any two parameters
display mode in each

Battery life: Rechargeable Ni-MH pack (charger included), 6 hrs typical (continuous)
Shock & Vibration: Mil 28800E, Type 3, Class III, Style B.
Operating temperature: 0°C to 50°C; Case: IP51 (dust, drip, waterproof)
Size (HxWxD): 232 mm x 115 mm x 50 mm; Weight: 1.1 kg
Three Years Warranty

Ordening information
Fluke 43B

Ranges
5.000 V - 1250 V
50.00A - 50.00 kA
40.0 - 70.0 Hz
1,0 à 10,0
250 W - 1.56 GW
0.25 W-0.9
0.90-1.00
1 st to 51 st harmonic
1 st to 51 st
1 st to 51 st
1.0 to 30.0
4 min-16 days selectable
Select 20/50/100/200%
above or below line voltage
1 A to 1000 A
500.0 Ω to 30.00 MΩ
50.00 nF to 500.0 μF
-100.0ºC to 400.0ºC
-200.0ºF to 800.0ºF
Sampling rate:
Bandwidth:
Voltage BW (Channel 1)
Current BW (Channel 2)
20 screens
4 min - 16 days selectable

Recommended Accessories

Power Quality Analyzer
(single-phase)

i2000flex
See page 114

i1000s
See page 114

80TK
See page 116

PAC91
See page 76

81

430 Series Three-phase
Power Quality Analyzers
Pinpoint power quality problems faster, safer and
in greater detail
The Fluke 435 and 434 three-phase power
quality analyzers help you locate, predict,
prevent and troubleshoot problems in
power distribution systems. These easy-touse handheld tools have many innovative
features to give you the details to pinpoint
problems faster and safer.

Fluke 435

Fluke 434

True RMS
On all inputs

• Complete three-phase troubleshooting
tool: measures virtually every power
system parameter: voltage, current,
frequency, power, power consumption
(energy), unbalance and flicker, harmonics
and inter-harmonics. Captures events like
dips and swells, transients, interruptions
and rapid voltage changes.
• The Fluke 435 features 0.1 percent voltage
accuracy making it fully compliant with
the IEC 61000-4-30 Class A standard
• Logger: record the detail you need.
Detailed, user-configurable long-time
recording gives you the MIN, MAX and AVG
readings of up to 100 parameters on all
4 phases with selectable averaging time
down to 0.5 seconds. Enough memory is
available to record 400 parameters with 1
minute resolution for up to a month.
• Four channels: simultaneously measures
voltage and current on all three phases
and neutral.
• AutoScaling: easier trend analysis with
automatic scaling of the vertical axis you
will always use the full display to view the
waveforms.
• Automatic transient display: captures up to
40 dips, swells, interruptions or transients
automatically.
• Meets the stringent 600 V CAT IV,
1000 V CAT III safety standard required for
measurements at the service entrance.
• Rugged, handheld instrument operates
for more than 7 hours on included
rechargeable NiMH battery pack. Menudriven interface simplifies operation.
• Extensive data analysis possibilities.
Cursors and zoom can be used ‘live’ while
taking the measurements, or ‘offline’ on
stored measurement data. The stored
measurements can also be transferred to a
PC with FlukeView software (included with
Fluke 435 and 434).
• The Fluke 435 comes with Power Log
software to analyse recorded data and to
create reports.
• Complete package includes everything to
get started: 4 current clamps, 4 flex clamps
with Fluke 435, 5 voltage test leads and
clips, line adapter/battery charger and hard
case.
• Complies with IEC 61000-4-30
measurement standards.

AutoTrend - Quickly see the trend
Unique AutoTrend gives you fast insight into
changes over time. Every displayed reading
is automatically and continuously recorded
without having to set up threshold levels
or interval times, or having to manually
start the process. You can quickly view
trends in voltage, current, frequency, power,
harmonics or flicker on all three phases plus
neutral. And you can analyze the trends
using the cursors and zoom function – even
while background recording continues.

SystemMonitor - Check performance
against EN50160 with ease
With a single push of a button, the unique
System-Monitor gives you an overview of
power system performance, and checks the
compliance of incoming power to EN50160
limits or to your own custom specifications.
The overview is shown on a single screen,
with color-coded bars clearly indicating
which parameters fall outside the limits.

The System-Monitor overview screen gives instant insight
into whether the voltage, harmonics, flicker, frequency and
the number of dips and swells fall outside the set limits.
A detailed list is given of all events falling outside the set
limits.

82

AutoTrend automatically records all displayed parameters
in the background.

430 Series Three-phase
Power Quality Analyzers

Logging function allows you to customize measurement
selections and provides instantaneous analysis of userselectable parameters.

Measure and record power (W), VA and VARs.
The 434 and 435 add the ability to record energy
consumption.

Track harmonics up to the 50th, and measure and record
THD in accordance with IEC61000-4-7 requirements

Specifications
(Check the Fluke web for detailed specifications)

Fluke 435 with flex clamps

Inputs

Number of inputs
Maximum input voltage
Maximum sampling speed

4 voltage and current (3 phases + neutral)
1000 Vrms (6kV Peak)
200 kS/s on each channel simultaneously

Volt/Amps/Hertz

Vrms (AC+DC)
Vpk
Crest factor, voltage
Arms (AC+DC)
Apeak
Crest factor, A
Hz
50Hz nominal
Vrms (AC+DC) 2
Arms (AC+DC) 2
Harmonic (interharmonic) (n)
Vrms
Arms
Watts

1…1000 V
± 0.1% of nominal voltage
1…1400 V
5% of Vnom
1.0 ... > 2.8
± 5%
0…20,000 A
± 0.5% ± 5 counts
0 - 5500 A
5%
1 … 10
± 5%
42.50 ... 57.50 Hz
± 0.01Hz
0.0% ….100% of Vnom
± 0.2% of nominal voltage
0 … 20,000 A1
± 1% ± 5 counts
DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
0.0 … 1000 V
± 0.05% of nominal voltage
0.0 … 4000 mV x clamp scaling
± 5% ± 5 counts
depends clamp scaling and
± 5% ± n x 2% or reading,
voltage
± 10 counts
0.0 … 1000 V
± 0.2% of nominal voltage
0.0 … 100.0 %
± 2.5% V and A (± 5% Watt)
0 … 3500 Hz
± 1 Hz
-360º ... +360º
± n x 1.5º
1.0 … 20.00 MVA1
± 1% ± counts
00.00 …200.0 GVAh1
± 1.5% ± 10 counts
0…1
± 0.03
0.00 … 20.00
±5%
0.0 … 5.0%
± 0.5%
0.0 … 20%
± 1%
± 6000 V
± 2.5% of Vrms
5 μs (200 kS/s sampling)
1
0.000 … 20.00 kA
± 1% of meas ± 5 counts
7.5 s … 30 min
± 20 ms (Fnom = 50 Hz)
5 readings/sec continous sampling per channel
1800 min, max and avg points for each reading
Up to 450 days
Up to 12x horizontal zoom
50, shared memory divided between logging, screens and data sets
IEC61000-4-30 class A; EN50160; IEC 61000-4-15; IEC 61000-4-7

Dips and swells
Harmonics

Included Accessories
Fluke 435/434: Hard carrying case C430 (434)/
Water-tight hard case with rollers C435 (435)
4 current clamps, i400s, CAT IV 600 V
(Fluke 434)
4 current clamps, i430-Flex-4pk, CAT IV
600 V (Fluke 435)
5 Test leads, 4 black, 1 green
Battery Charger Eliminator, BC430
FlukeView Software, SW43W
Power Log Software (435)
Optical Cable for USB, OC4USB
Color localization set, WC100
Getting Started printed
User Manual (CD-ROM)
Basic versions: Excl. current clamps

Power and Energy

Flicker
Unbalance
Transient capture
Inrush mode
AutoTrend recording

Memory
Standards

DC voltage
THD
Hz
Phase angle
Watt, VA, VAR
kWh, kVAh, kVARh
Power Factor/ Cos ij / DPF
Pst (1min), Pst, Plt, PF5
Volts
Current
Volts
Minimum detect duration
Arms (AC+DC)
Inrush duration (selectable)
Sampling
Memory
Recording time
Zoom
Screens & data
Measurement methods used

Ordering information
Fluke 435/Basic
Fluke 435
Fluke 434/Basic
Fluke 434
Fluke 434/LOG
OC4USB
PM9080
GPS430

Power Quality Analyzer
(three phase)
Power Quality Analyzer
(three phase)
Power Quality Analyzer
(three phase)
Power Quality Analyzer
(three phase)
Logger Upgrade Kit: Adds
the Logger Function of
the 435 to the 434
Serial Interface Adapter/
Cable (USB)
Serial Interface Adapter/
Cable (RS232)
GPS sync module
for 430 Series

1
2

depending clamp scaling
Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle

Battery life: > 7 hours with rechargeable NiMH (installed); Battery charging time: 4 hours typical
Safety: EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV
Case: Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof)
Shock: 30 g; Vibration: 3g according to MIL-PRF-28800F Class 2
Operating temperature: 0°C to +50°C
Size (HxWxD): 256 mm x 169 mm x 64 mm; Weight: 1.1 kg
Three Years Warranty

Recommended Accessories

GPS430

i430-flex-4pk
See page 88

i5sPQ3
See page 88

i1000s
See page 144

OC4USB
See page 76

See page 88 for power quality current clamps

83

1735 Power Logger
Performs electrical load studies, energy
consumption testing, and general power
quality logging

Fluke 1735

The Fluke 1735 Power Logger is the ideal
tool for electricians and maintenance
technicians for conducting energy
studies and basic power quality logging.
The 1735 is easy to set up with its color
display and four included flexible current
probes.
The 1735 logs most electrical power
parameters, harmonics and captures
voltage events. View graphs and generate
reports with the included Fluke Power
Log software.

View recorded data in simple graphs and
tables with Fluke Power Log software.

• Record power and associated
parameters for up to 45 days
• Monitor maximum power demand over
user-defined averaging periods
• Prove the benefit of efficiency
improvements with energy
consumption tests
• Measure harmonic distortion caused by
electronic loads
• Improve reliability by capturing voltage
dips and swells from load switching
• Confirm instrument setup easily with
color display of waveforms and trends

Conduct load studies
for up to 45 days and
view saved data
on-screen or on a
computer.

Access voltage and
current harmonics
up to the 50th.

Quantify energy
consumption quickly
on-screen or log to
memory for extended
periods.

Capture voltage events
using user-defined
thresholds.

Customize the report generator to easily
generate professional looking reports.

Specifications
(Check the Fluke web for detailed specifications)
Volts rms

Amps rms
Frequency
Harmonics and THD
Power measurement
(P - Active, S - Apparent, Q - Reactive, D - Distorting)
Energy Measurement (kWh, KVAh, kVARh)
PF (Power factor)
Events

General
Memory
Sample rate
Line frequency

Included Accessories
FS17XX 4-phase flexible current clamp set,
VL1735/1745 voltage lead set, Power Log
software, color localization set, PC interface
cable, international ac adapter, BC1735 battery
charger, soft carrying case, printed English
manual and multi-language manual on CD.

Ordering Information
Fluke 1735

Power Logger

V-rms wye measurement ranges:
57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/
400 V/417 V/480 V AC
V-rms delta measurement ranges:
100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/
690 V/720 V/830 V AC
Flexi set measurement range: 15 A/150 A/3000 A rms (at sine)
Current clamp measurement range: 1 A/10 A
Measurement range: 46 Hz to 54 Hz and 56 Hz to 64 Hz
To 50th harmonic (< 50 % of nom)
Measuring range: see V-rms and A-rms measurement ranges
Measuring range: see V-rms and A-rms measurement rangeso
0.000 to 1.000
Detection of voltage dips, voltage swells and voltage interruptions with a
10 ms resolution and measuring error of the half period sine wave of rms.

4 MB Flash memory, 3.5 MB for measuring data
10.24 kHz
50 Hz or 60 Hz, user-selectable, with automatic synchronization

Display: VGA Graphic Color transmissive displays
320 x 240 pixels with additional background lighting
and adjustable contrast, text and graphics in color
Interface: RS-232 SUB-D socket; 115.2 k Baud,
8 data bits, no parity, 1 stop bit, firmware updates are
possible with the RS-232 interface (9-pole extension
cable)
Housing: IP65; EN60529 (refers only to the main
housing without the battery compartment)

Power supply: NiMH battery-pack, with AC adapter
(15 V to 20 V/0.8 A)
Battery Life: Typical > 16 hours without backlight and
> 6 hours with backlight high
Operating temperature: 0°C to +40°C
Size (HxWxD): 240 mm x 180 mm x 110 mm
Weight: 1.7 kg, including battery
Two Year Warranty

Recommended Accessories
See page 88 for power quality current clamps

84

1740 Series Three-Phase
Power Quality Loggers Memobox
Assess power quality and conduct long-term
studies with ease
Compact, rugged and reliable, the Fluke
1740 Series three-phase power quality
loggers are everyday instruments for
technicians who troubleshoot and
analyze power distribution systems.
Capable of simultaneously logging up
to 500 parameters for up to 85 days and
capturing events, the Fluke 1740 Series
helps uncover intermittent and hard-tofind power quality issues. There are three
models to choose from to meet your
basic or advanced power logging needs.
Fluke 1743

Fluke 1744

Fluke 1745

Fluke 1743: IP65 waterproof monitor
for logging the most common power
parameters including V, A, W, VA, VAR, PF,
energy, flicker, voltage events and THD.

• Plug and play: Set up in minutes with
automatic current probe detection and
powering
• Installs inside the cabinet: Compact,
fully-insulated housing and accessories
fit easily in tight spaces next to live
power
• Monitors power for the long-term:
Data can be downloaded during
recording without interruption
• Measure voltage with premium
accuracy: IEC61000-4-30 Class-A
compliant voltage accuracy (0.1%)
• Quickly validate quality of power:
Assess power quality according to
EN50160 power quality standard with
statistical overview

Fluke 1744: Includes the same features
as the Fluke 1743. In addition to common
power parameters, the Fluke 1744 also
measures voltage and current harmonics,
interharmonics, mains signaling,
unbalance, and frequency.
Fluke 1745: Advanced IP50 power quality
logger with the same measurement
capability as the 1744, plus real-time LCD,
five hour UPS.

Specifications

The included PQ Log software helps you
to quickly identify the root cause of a
disturbance.

Included Accessories
Fluke 1743/1744/1745: FS17XX flexible current
clamp set , VL1735/1745 voltage lead set (1745
only), Power Log software, RS232 interface
cable and RS232-USB adapter, 4 black dolphin
clips, WC17XX color localization set, carrying
bag, test certificate with measurement values,
printed English manual and multi-language
manual on CD.
Basic models: Excl. current clamps FS17XX

Ordering Information
Fluke 1743 Basic
Fluke 1743
Fluke 1744 Basic
Fluke 1744
Fluke 1745

Power Quality Logger
Memobox
Power Quality Logger
Memobox
Power Quality Logger
Memobox
Power Quality Logger
Memobox
Power Quality Logger
Memobox

(Check the Fluke web for detailed specifications)

Measurement of common power parameters: V, A, W,
VA, VAR, PF, energy, flicker, voltage events (dips, swells,
interruptions), and THD
Measurement of voltage and current harmonics to the
50th, unbalance, frequency and mains signaling
Dust/water resistance
Display
Memory
UPS ride-through
EN 50160

1745
O

1744
O

O

O

IP 50
LED + LCD
8 MB
> 5 hrs
O

LED
8 MB
3s
O

Power supply: 88 V … 660 V AC
Safety: IEC/EN 61010-1 600 V CAT III, 300 V
CAT IV, pollution degree 2, double insulation
Housing: Fully insulated housing and accessories
Operating temperature: 0 °C to 35°C
Interface: RS 232, 9600 ... 115 000 Baud, automatic
Baud rate selection, 3-wire communication

1743
O

IP 65 waterproof
LED
8 MB
3s
O

Fluke 1745: 282 mm x 216 mm x 74 mm;
Fluke 1743/44: 170 mm x 125 mm x 55 mm
Weight: Fluke 1745 – approx. 3 kg;
Fluke 1743/44: approx. 2 kg
Two Year Warranty
Size:

See page 88 for power quality current clamps
85

1750 Three-Phase Power
Recorder
New

Never miss capturing a disturbance
With its exclusive threshold-free
measurement system, the Fluke 1750
Power Recorder
captures every measurement, every event,
on every cycle, all the time. Outstanding
accuracy and resolution provide complete
visibility into your installation or
distribution system.

On all inputs

• Power quality that meets the standard:
All measurements comply with
IEC61000-4-30 standards for correct
evaluation of all measured values
including voltage, current, power,
harmonics, flicker etc.
• Quick and reliable configuration: PDA
wireless “front panel interface” provides
the ability to verify setup without a
laptop along with a window into what
the instrument is recording, even in
awkward test locations.
• Threshold-free setup: Apply thresholds
after data is collected with Fluke Power
Analyzer Software so there is no need to
worry about missed information due to
incorrect set-up.

• Captures everything: Cross-channel
and current triggering capture every
measurement, on every channel, every
time.
• Intuitive PC software: Easily analyze
data and generate reports. Automated
EN50160 reporting and compliance.
• Plug and play: Set up in minutes with
selfidentifying current probes and
single-lead voltage connections.
• No need to reconnect wires: Swap
channels internally with the wireless
PDA or PC when connections are not
correct.
• Measure every parameter: Voltage and
current on three phases, neutral, and
ground.
• 5 MHz, 8000 Vpk waveform capture:
Get a detailed picture of even the
shortest events.
• Quickly retrieve data: With included SD
memory card or via the 100BaseT highspeed Ethernetv connection

View measurements real time with wireless PDA interface

Specifications
(Check the Fluke web for detailed specifications)
Power quality measurement standards
Conformance
Clock/calendar
Real-time clock accuracy
Internal memory capacity for data
Maximum recording period
Measurement time control
Maximum number of events
Power requirements
Operating time during interruptions (internal UPS operation)

Included Accessories
PDA and charger power plug adapters, 4 - 400
A current probes (3140R), 5 test leads and
clips, SD memory card., Fluke Power View and
Fluke Power Analyze software,
power cord with international plug set,
Ethernet cable, color localization set, soft
carrying case, Printed Getting Started manual,
CD with software and users manual PDF
Basic model: excl. 4 current probes (3140R)

Ordering Information
Fluke 1750/B
Fluke 1750

86

Three-Phase Basic Power
Recorder
Three-Phase Power
Recorder

IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160

Leap years, 24-hour clock
Not more than ± 1 s/day
At least 1 GB
At least 31 days
Automatic
Limited only by the size of the internal memory
100 to 240 V rms ± 10 %, 47-63 Hz, 40 W
5 minutes per interruption, 60 minutes total operating time without recharging

Safety: EN 61010-1 2nd Edition; 2000
Weight: 6.3 kg
Size (H x W x D): 215 x 310 x 35 mm
One Year Warranty

Recommended Accessories
Model
3110-PR
3210-PR
3310-PR
3312-PR
3005-PR
3014-PR
3140R
FLUKE-1750/SEAT-L
FLUKE-1750/SITE-L
FLUKE-1750/CASE
CS1750
HP IPAQ 2490
FLUKE-1750/MC

Description
Flexible Current Transformer (2 A - 100 A)
Flexible Current Transformer (20 A – 1000 A)
Flexible Current Transformer (100 A - 5000 A)
Flexible Current Transformer (100 A – 5000 A)
Clamp-on Current Transformer (0.01 A – 5 A)
Clamp-on Current Transformer (0.1 A – 40 A)
Clamp-on Current Transformer (2 A – 400 A)
Fluke Power Analyze – Additional SEAT LICENSE
Fluke Power Analyze – Additional SITE LICENSE
Hard Case
Soft Case
Additional Wireless Interface PDA
Additional 512 MB SD Memory Card

1760 Three-Phase Power
Quality Recorder Topas
Class-A compliance for the most demanding
power quality tests

Fluke 1760

The Fluke 1760 Three-Phase Power
Quality Recorder is fully compliant to
IEC 61000-4-30 Class-A, for advanced
power quality analysis and consistent
compliance testing. Designed for analysis
of utility and industrial power distribution
systems, in medium and low-voltage
networks, the Fluke 1760 provides the
flexibility to customize thresholds,
algorithms, and measurement selections.
It has 8 input channels (4 currents/4
voltages or 8 voltages), and captures the
most comprehensive details on user
selectable parameters.

• GPS time synchronization: Correlate
data with events or datasets from other
instruments with precision
• Uninterrupted power supply
(40 minutes): Never miss important
events - even record the beginning and
end of interruptions and outages
• 10 MHz, 6000 Vpk waveform capture:
Get a detailed picture of even the
shortest event
• 2 GB data memory: Enables detailed,
simultaneous recording of numerous
power parameters for long periods of
time
• Includes Comprehensive software:
Provides trend diagrams for root cause
analysis, statistical summaries, report
writing and real-time data monitoring
in the online mode

Features
(Check the Fluke web for detailed specifications)

The included PQ Analyze software
provides a detailed overview of several
power quality parameters on one
dashboard according to the EN50160
power quality standard.

Included Accessories
4 x TPS Flex 24 flexible current probe, 4 x
TPS VoltProbe 6000V, 2 GB internal flash
memory, ST1760 standard Ethernet cable,
RS232 interface cable and RS232-USB adapter,
CS1760 crossover Ethernet cable, 1 mains
cable, PC software on CD-ROM, WC17xx color
localization set, GPS-time sync (1760TR only)
CS 1750/1760 carrying bag, hardware and
software manual
Basic models: Excl. current clamps TPS flex 24

Ordering Information
Fluke 1760 Basic

Power Quality Recorder
Topas
Fluke 1760TR Basic Power Quality Recorder
Topas
Fluke 1760
Power Quality Recorder
Topas
Fluke 1760TR
Power Quality Recorder
Topas

Power quality statistics according to EN50160
Voltage event list (dips, swells and interruptions)
Continuous recording of:
Voltage
Current
Power P, Q, S
Power factor
kWh
Flicker
Unbalance
Frequency
Voltage and current harmonics to the 50th/
Interharmonics
THD
Mains signaling
Triggered recordings
Online mode (Oscilloscope, transients and events)
Fast transient analysis up to 10 MHz
4 voltage probes
4 dual-range flexible current probes (1000 A / 200 A ac)
GPS time sync receiver
Memory

1760 Basic

1760TR Basic

1760

1760TR

O
O

O
O

O
O

O
O

O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O
O

O
O
O
O

O
O
O
O
O

O
O
O
O

O
O
O
O
O
O
O
O

O
O
O
2 GB Flash memory

Power supply: 83 V to 264 V, 45 to 65 Hz
Battery pack: NIMH, 7.2 V, 2.7 Ah (up to 40 minutes
back-up power supply)
Safety: 600V CAT IV/1000V CAT III
(Rated for use at the service entrance)
Housing: Fully insulated robust plastic housing

Operating temperature: 0 °C to 35°C
Interfaces:
Ethernet (100 MB/s), RS-232, external
modem via RS-232
Size (HxWxD): 325 mm x 300 mm x 65 mm
Weight: Approxiamtely 4.9 kg
Two Year Warranty

Recommended Accessories
(Check the Fluke web for complete accessory list)
Model
• TPS VOLTPROBE 10 V
• TPS VOLTPROBE 100 V
• TPS VOLTPROBE 400 V
• TPS VOLTPROBE 600 V
• TPS VOLTPROBE 1 KV
• TPS FLEX 18
• TPS FLEX 24
• TPS FLEX 36
• TPS CLAMP 10 A / 1 A
• TPS CLAMP 50 A / 5A
• TPS CLAMP 200 A / 20 A
• TPS SHUNT 20 MA
• TPS SHUNT 5 A

Description
10 V Voltage Probes (Range: 0.1 V to 17 V)
100 V Voltage Probes (Range: 1 V to 170 V)
400 V Voltage Probes (Range: 4 V to 680 V)
600 V Voltage Probes (Range: 10 V to 1000 V)
1000 V Voltage Probes (Range: 10 V to 1700 V)
Flexible Current Probe (Range: 1 A to 100 A / 5 A to 500 A)
Flexible Current Probe (Range: 2 A to 200 A / 10 A to 1000 A)
Flexible Current Probe (Range: 30 A to 3000 A / 60 A to 6000 A)
Clip-on Current Transformer (Range: 0.01 A to 1 A / 0.1 A to 10 A)
Clip-on Current Transformer (Range: 0.05 A to 5 A / 0.5 A to 50 A)
Clip-on Current Transformer (Range: 0.2 A to 20 A / 2 A to 200 A)
20 mA ac/dc Shunt (Range: 0 to 55 mA)
5 A ac/dc Shunt (Range: 0 to 10 A)

87

88

Basic accuracy: % reading plus floorspec.
n/a = not applicable

1

BNC to banana adapters included

n/a

i3000 flex-4PK
(4x i3000s flex24)

n/a

One connector
n/a

One connector

i400s

n/a

One connector

2
CAT III 600 V

n/a

n/a

One connector

2
CAT III 600 V

i430-flex-4PK

One connector

2
CAT III 600 V

n/a

One connector

2
CAT III 1000 V
CAT IV 600V

One connector

2
CAT III 600 V

3.75 mV/A

Connection

2
CAT III 600 V

3.75 mV/A

3300 A
450 mA
2%+2% position
influence
40Hz …5kHz

450mA … 15A
600mA… 150A
6A… 1500A
12A… 3000A

15A 150A 1500A
3000A AC

O
O

MBX Lem Flex
(15/150/3000)
(EP0404A)

2
CAT III 600 V

15 mV/A

40 Hz ... 10
kHz

300 A
200 mA
0.5%

FS17xx IP65

i5sPQ3

n/a

One connector

2
CAT III 1000 V
CAT IV 600V

0.1 mV/A

61 cm

3300 A
450 mA
2%+2% position
influence
40Hz …5kHz

450mA … 15A
600mA… 150A
6A… 1500A
12A… 3000A

15A 150A 1500A
3000A AC

O
O

MBX Lem Flex
(15/150/3000)
(EP0404A)

4 Phase flexiset, 4 Phase flexiset,
IP41
IP65

FS17xx

Output cable (m)
Safety rating

15 mV/A

40 Hz ... 10
kHz

300 A
200 mA
0.5%

200 mA ...
20 A
2 A ... 200 A

20 A
200 A AC

O
O

MBX CLAMP
20/2000A+N
(EPO456A)

4 ... phase
20A/2000A
Mini current
clamp set

i20A/200A
CLAMP PQ4

0.1 mV/A

75 mV/A

40 Hz ... 10
kHz

100 A
50 mA
0.5%

200 mA ...
20 A
2 A ... 200 A

20 A
200 A AC

O
O

MBX CLAMP
20A/200A
(EPO455A)

3 ... phase
20A/200A
Mini current
clamp set

i20A/200A
CLAMP PQ3

75 mV/A

40 Hz ... 10
kHz

100 A
50 mA
0.5%

50 mA ... 5A
500 mA ...
50 A

5A
50 A AC

O
O

MBX CLAMP
5A/50A+N
(EPO453A)

4 ... phase
5A/50A Mini
current clamp
set

i5A/50A
CLAMP PQ4

Output level(s)

40 Hz ... 10
kHz

20 A
10 mA
0.5%

50 mA ... 5 A
500 mA ...
50 A

5A
50 A AC

O
O

MBX CLAMP
5A/50A
(EPO452A)

3 ... phase
5A/50A Mini
current clamp
set

i5A/50A
CLAMP PQ3

61 cm

40 Hz ... 10 kHz

20 A
10 mA
0.5%

10 mA ... 1 A
100 mA ...
10 A

1A
10 A AC

1A
10 A AC

10 mA ... 1 A
100 mA ... 10 A

O
O

MBX CLAMP
1A/10A+N
(EPO451A)

4 ... phase
1A/10A Mini
current clamp
set

i1A/10A
CLAMP PQ4

O
O

CURRENT
CLMAPS 1A
(EPO450A)

3 ... phase
1A/10A Mini
current clamp
set

i1A/10A
CLAMP PQ3

Requires battery
Flex head length

Usable frequency

Highest current
Lowest measurable current
Basic accuracy (48 ... 65 Hz) 1)

Cont. AC current range

Fluke 1735
Fluke 174X
Fluke 43X
Nominal current range(s)

Old Fluke model #

Descript ion

Fluke model number

O

4 x BNC

10 mV/A
1 mV/A
0.1 mV/A
2.1
CAT III 600 V

10 Hz ... 100
kHz
O

4000 A
1A
2% + 2 A

O
30 A
300 A
3000 A
1 A ... 30 A
1 A ... 300 A
1 A ... 2400 A

4 ... phase
3000A Flexible
current clamp
set

i3000 flex ... 4PK

4 x BNC

2.5
CAT III 1000 V
CAT IV 600 V

Clamp
opening:
32 mm
10 mV/A
1 mV/A

45 Hz ... 3 kHz

1000 A
0.5 A
2% + 0.15 A

0.5 A ... 40 A
5 A ... 400 A

O
40 A
400 A

Single phase
400A current
clamp
(4 required)

i400s

4 x BNC

2.5
CAT III 1000 V
CAT IV 600 V

0.085 mV/A
@50 Hz

61 cm

10 Hz ... 7 kHz

100 kA
30 A
1%

30 A ... 3000 A

O
3000 A

4 ... phase
3000A
Flexible
current clamp
set

i430 ... flex ... 4PK

3 x BNC

2.5
CAT III 600 V

Clamp
opening:
15 mm
400 mV/A

40 Hz ... 5 kHz

70 A
10 mA
1%

0.01 A ... 6 A

O
5A

3 ... phase 5A
Current clamp
set

i5sPQ3

Power Quality Current Clamps

Norma 4000/5000
Power Analyzers
Reliable, highly accurate measurements for
the test & development of power electronics

Fluke Norma Series Power Analyzers

The compact Fluke Norma Series
Power Analyzers provide the latest
measurement technology to assist
engineers with the development and
testing of motors, inverters, lighting,
power supplies, transformers and
automotive components.

The Series consists of the Fluke Norma
4000 Three-Phase Power Analyzer and
the Fluke Norma 5000 Six-Phase Power
Analyzer. These rugged analyzers provide
unmatched price performance for easy
and reliable use in the field, or as a bench
unit in laboratories and on test benches.

Based on a patented, high-bandwidth
architecture, the instruments deliver
high-precision measurements of single
or three-phase current and voltage,
harmonics analysis, Fast Fourier
Transformation (FFT) analysis, as well as
calculations of power and other derived
values.

• Simple user interface ensures easy,
intuitive operation
• Unique user-configurable modular
design
• Simultaneous parallel acquisition of all
phases
• Voltage, current and power harmonics
up to the 40th
• Includes FFT analysis, vector diagram
display, recorder function, and Digital
Oscilloscope (DSO) mode
• User selectable average time – from
15ms to 3600s
• Expandable on-board memory for
storage of measured values

A unique user-configurable system
design with plug-in power phases and
other optional modules provides the
flexibility to meet a variety of application
measurement requirements. Recorded
data and waveforms can be viewed
clearly in the large color display and
easily downloaded to a PC for analysis
and report writing.
Fluke Norma 4000

Fast Fourier
Transformation (FFT)
analysis

Digital Oscilloscop
(DSO) mode

Vector Display

Recorder function

Specifications
(Check the Fluke web for detailed specifications)

Fluke Norma 5000

Included Accessories

Number of Phases
Weight
Size (HxWxD)
On-board Printer
Display
Bandwidth
Basic Accuracy
Sampling Rate
Voltage Input Range
Current Input Range (direct, not via shunt)
Memory for Configurations
Memory for Settings
Fast Fourier Transformation (FFT)
RS232 Interface
PI1 Process Interface (8 analog/impulse inputs and
4 analog outputs)
IEEE 488.2 /GPIB Interface (1 MBit/s Ethernet /
10 MBit/s or 100 Mbit/s)
Fluke NormaView PC Software (for data download,
analysis & report writing)

Fluke Norma 4000
Fluke Norma 5000
1 or 3
3, 4 or 6
Approx. 5 kg
Approx. 7 kg
15 cm x 23.7 cm x 31.5 cm
15 cm x 44.7 cm x 31.5 cm
No
Yes (optional)
Color, 5.7“ / 144 mm - 320 x 240 pixel
dc to 3 MHz or dc to 10MHz depending on input module
0.2%, 0.1% or 0.03% depending on input modules
0.33 MHz or 1 MHz depending on input modules
0.3 V to 1000 V
0.03 mA – 20 A depending on input module
4 MB, expandable to 128 MB
0.5 MB
To the 40th harmonic
Standard
Optional
Optional
Standard

Power Supply Cable, RS232 Interface and USB
adaptor for Data Download, Fluke NormaView
PC Software, User’s Manual, Test Certificate,
and Calibration Values.

Ordering Information
Fluke Norma 4000
Fluke Norma 5000

Three-Phase High
Precision Power Analyzer
Six-Phase High Precision
Power Analyzer

Operating temperature:
+ 5 °C to 35 °C
Storage temperature:
- 20 °C to 50 °C
Climatic class: KYG DIN 40040, maximum
85% relative humidity, non-condensing.

Housing: Solid metal case
Safety: EN 61010-1 / 2nd Edition, 1000 V CAT II
(600 V CAT III)
Two Year Warranty

89

Norma 4000/5000
Power Analyzer Accessories
Power Phases

Fluke Norma 4000 (rear view)

The Fluke Norma 4000 Power Analyzer
can be equipped with up to three power
phases and the Fluke Norma 5000 Power
Analyzer can be equipped with up to six
power phases. Users can select the power
phase best suited for their application.
Specifications vary depending on the model
of the power phase.

Each plug-in power phase consists of
a voltage and a current measurement
channel. Each measuring channel is
available for each basic unit.

Power Phase Overview
Channel
Accuracy
Current range
Sampling rate
Bandwidth

3024770
PP42
0.2%
(0.1% rd + 0.1% rg)
20 A
341 kHz
3 MHz

3024812
PP50

10 A
1 MHz
10 MHz

3024820
PP54
0.1%
0.05% rd + 0.05% rg
10 A
341 kHz
3 MHz

3024835
PP64
0.03%
(0.02% rg + 0.01% rg)
10 A
341 kHz
3 MHz

Fluke Norma 5000 (rear view)

Shunts
The input modules can take up to 10 A
or 20 A directly or measure current via
wideband precision shunts. The available
range of shunts enables measurements up
to 1500 A and can be used in conjunction
with all of the available input modules.

3024677
3024689
3024886
3024899
3024847
3024858
3024864
3024873
3024692

32 A Planar Shunt
Cables for 32 A Planar Shunt
10 A Triaxial Shunt with Cables
(0.333 ., 0 to 0.5 MHz)
30 A Triaxial Shunt with Cables
(0.010 ., 0 to 0.5 MHz)
100 A Shunt with Cables (0.001 Ω, 0 to 0.5 MHz)
150 A Shunt with Cables (0.5 mΩ, 0 to 0.5 MHz)
300 A Shunt with Cables (0.1 mΩ, 0 to 1 MHz)
500 A Shunt with Cables (0.1 mΩ, 0 to 0.2 MHz)
LG Shunt Cables for High Current Shunts

Cables & Adaptors
3024661
3024704

Measurement Cable Set (for one power phase)
Fluke Norma WYE Adaptor (external accessory
box)

Printer Accessories
3024650

Printer Cable for Fluke Norma 5000
(RS232-Centronics)

All accessories have a
two-year warranty.
90

Optional shunts for Fluke Norma Series Power
Analyzers

32 A Planar Shunt

Field Calibrators
Fluke process calibration tools include a full range of calibrators and
troubleshooting tools for instrument technicians working in the process
industries. The range of process calibrators include: Documenting
Process Calibrators, Multifunction Process Calibrators, single function
and multifunction temperature calibrators, a variety of mA loop
calibrators and a range of intrinsically safe products.

91

O
3
93

O
3
93

2

1

O
3
93

24 V

O

O
O
O

24 V

O

15 V
11 kΩ
22 mA
O
50 kHz
8
11

8
11

50 kHz
O1

300 V
300 V
11 kΩ
110 mA

741B

O

15 V
11 kΩ
22 mA
O
50 kHz
8
11

8
11

24 V
O

O
O
O
O
O

15 V
11 kΩ
22 mA
O
50 kHz
8
11

Fluke 700 pressure modules required
Ranges for the internal sensor.
Ranges for use of Fluke 700 pressure modules, see page 102.

Record
Min/Max
Hold
As Found/As Left results
Log data
Upload data to PC
Remote operation
Features
Loop supply
Hart communication
Integrated hand pressure pump
Electric Pump
Intrinsically safe (ATEX)
NIST traceable certification
Warranty in years
See catalog page

Source/Simulate
Voltage DC
Resistance
mA DC/% scale
mA source; auto step, auto ramp
Frequency
Temperature: RTD types
Temperature: TC types

8
11

50 kHz
O1

Current AC
Frequency
Pressure

Temperature: RTD types
Temperature: TC types

300 V
300 V
11 kΩ
110 mA

300 V
300 V
11 kΩ
110 mA

50 kHz
O1

743B

744

92

Model
Measure
Voltage DC
Voltage AC (true RMS)
Resistance
Current DC

Documenting Process Calibators

24 V

O
3
94

725Ex
O
3
94

O

20 V
4000 Ω
24 mA
O
15 kHz
8
10

8
12

24 V/12 V

O/-

10 V
3200 Ω
24 mA
O
10 kHz
7
10

7
12

15 kHz
O1

4000 Ω
24 mA

3200 Ω
24 mA

10 kHz
O1

30V

726

30 V

725/725Ex

Multifunction Process
Calibrator

O
3
95

24 V

7
10

10 V
3200 Ω

7
12

3200 Ω
24 mA

30 V

724

O
3
96

9

75 mV

9

75 mV

714

O
3
96

7

3200 Ω

7

3200 Ω

712

Temperature Calibrators

718Ex
O
3
98

O

24 V/-

O
O

68,9 mbar
to 20 bar /
2 to 7 bar2

24 mA

718/718Ex

O
3
98

24 V

O
O

68,9 mbar
to 345 bar2

24 mA

717

719

O
3
98

O

24 V

O
O

O

2 bar to
7 bar2

24 mA

Pressure Calibrators

O
3
99

24 V

24 mA
O

10 V

24 mA

10 V

715

707Ex
O
3
99

24 V

24 mA
O

24 mA

28 V

707/707Ex

3
100

O

100 mA

771

3
100

24 V

O

24 mA
O

100 mA

772

Loop Calibrators

3
100

24 V

O

24 mA
O

10 V

100 mA

30 V

773

O
3
99

24 V

24 mA
O

24 mA

28 V

705

3
101

24 V

O

O
O

24 mA
O

1000 V
1000 V
40 MΩ
30 mA,
1A
O
20 kHz

789

3
101

O
O

24 mA
O

O
20 kHz

1000 V
1000 V
40 MΩ
30 mA, 1A

787

ProcessMeters

Field Calibrator
Selection Guide

740 Series Documenting
Process Calibrators
Calibrators as versatile as you are

Fluke 743B
Fluke 744

The 740 series Documenting Process
Calibrators are rugged, handheld tools
for the calibration and troubleshooting of
process control instrumentation. These
calibrators:
• Calibrate temperature, pressure,
voltage, current, resistance, and
frequency
• Simultaneously measure and source
• Automatically capture calibration
results
• Document procedures and results to
meet ISO 9000, EPA, FDA, OSHA, and
other government requirements
• Measure/simulate eleven types of
thermocouples and eight RTDs
• Store up to 8,000 readings in data
logging mode (743B +744 only)
• Protected against dirt, dust, and
moisture; unaffected by vibration
• PC interface (743B +744 only)
• Operates in English, French, German,
Italian, and Spanish
• One and two-year calibration cycles
• Four types of built-in automated
calibration procedures; linear
transmitter, square root devices, one
and two-point limit switches

741B: A complete documenting
calibrator
Fluke 741B

The 741B is the economical choice for
plants that don’t use PCs or that require
traditional paper forms. It has storage
capacity for a day’s calibration and
measurement data. When you’re back at
the shop, recall the data on-screen to fill
out calibration forms.

743B: More memory, plus a PC
interface and data logging
The 743B has all the capabilities of
the 741B plus a PC interface that lets
you download procedures, lists, and
instructions created with software–or
upload data for printing, archiving, and
analysis. With its expanded memory, the
743B can hold a full week of calibrations
and procedures.

744: Get HART-ability
The Fluke 744 offers all of the capabilities
of the 743B, plus the ability to calibrate,
maintain, and troubleshoot HART
instrumentation with just one tool. This
rugged, reliable tool offers:
• Integrated HART communication
functions, permitting you to
monitor, control, and calibrate HART
instrumentation.
• NiMH battery with 3500 mA hour life
and battery indicator.

Instrumentation Management
Software
The Fluke 743B and 744 are compatible
with Fluke 700SW DPC/TRACK software
and with software from Cornerstone,
Fisher-Rosemont, Honeywell, Yokogawa,
Prime Technologies and On Time Support.

Included Accessories
Fluke 741B/743B: TL224 Industrial Test Leads
(2 sets), AC220 Test Clips (2 sets), TP220 Test
Probes (1 set), BP7217 Battery Pack, BC7217
Battery Charger, Instruction Manual, NIST
Traceable calibration certificate and data,
three-year warranty, serial port cable (743B
only), DPC/TRACK Sample Version with free PC
communication utility software (743B only).
Fluke 744: TL224 Industrial Test Leads
(2 sets), AC220 Test Clips (2 sets), TP220 Test
Probes (1 set), BP7235 NiMH Battery Pack,
BC7217 Battery Charger, serial port cable,
HART communications cable, DPC/TRACK
Sample Version with free PC communication
utility software, Instruction Manual, HART
Users Manual, NIST Traceable calibration
certificate and data.

Specifications
(Check the Fluke web for detailed specifications)
Function
Voltage DC
Current DC
Resistance
Frequency
Thermocouples
RTDs
Pressure

Measure
Sourcing
0.025% reading + 0.005% full scale
0.01% output + 0.005% full scale
0.01% reading + 0.015% full scale
0.01% output + 0.015% full scale
0.05% reading + 50mΩ
0.01% output + 40mΩ
0.05%
0.01 %
0.3ºC
0.2ºC
0.3ºC
0.1ºC
To 0.05% of full scale. See Pressure Module specifications.

Operating temperature: -10º C to 50º C
Safety: CAT II 300V
Battery Life: Typically over eight hours
Internal Battery Pack: NiCd, 7.2V, 1700 mAh

Ordering Information
Fluke 741B
Fluke 743B
Fluke 744
700SW

Battery Replacement: Via snap-shut door
without opening calibrator; no tools required
Weight: 1.4 kg
Size (HxWxD): 236 mm x 130 mm x 61 mm
Three Year Warranty

Recommended Accessories

Documenting Process Calibrator
Documenting Process Calibrator
Documenting Process Calibrator
DPC/Track Software
C789
See page 118

TL220
See page 110

80PK-8
See page 116

80PK-25
See page 116

700P27
See page 102

93

725/725Ex/726 Multifunction
Process Calibrators
More calibration power!

Fluke 725

Fluke 726

Fluke 725Ex

Features
Simultaneous Function
Capability
24.000 mA DC
24.000 mA DC with
24 V loop supply
100.00 mV DC
30.000V DC measure
20.000V DC Measure
10.000V DC Source
20.000V DC Source
15 to 3200 Ohms
5 to 4000 Ohms
Thermocouple J, K, T, E, R, S, B, M,
L, U, N, XK, BP
RTD Cu 10, Ni120; Pt100 (392);
Pt100 (JIS); Pt100, 200, 500, 1000
(385)
Pressure (requires Fluke 700 PXX
Modules)
Frequency; 10 kHz; (15 kHz)

Channel A

Channel B

M
M

M or S
M or S

M

M or S
M or S
M or S
M or S
M or S
M or S

M

725/725Ex/726 Multifunction
Process Calibrators

726 Precision Multifunction
Process Calibrator

• Two separate channels; measure, source
and view process signals simultaneously
• Measure volts, mA, RTDs,
thermocouples, frequency, and
resistance to test sensors and
transmitters
• Source/simulate volts, mA,
thermocouples, RTDs, frequency, and
pressure to calibrate transmitters
• Measure or *source pressure using any
of 29 Fluke 700Pxx Pressure Modules
• Source mA with simultaneous pressure
measurement to conduct valve and I/P
tests
• Perform fast linearity tests with auto
step and auto ramp features
• Power transmitters during test using
24 V loop supply and simultaneous mA
measurement
• Store frequently-used test setups for
later use
• For 725Ex version see also page 106 and
107
*Pressure pump required

Additional features:
• More precise measurement and
calibration source performance,
accuracies of 0.01%
• Transmitter error% calculation
• Memory storage for up to 8 calibration
results
• Frequency totalizer and frequency
pulse train source mode for enhanced
flowmeter testing
• HART mode inserts 250 ohm
resistor in mA measure and source
for compatibility with HART
instrumentation
• Integrated pressure switch test allows
you to capture the set, reset and
deadband of a switch
• Custom RTD curves, add calibration
constants for certified RTD probes for
enhanced temperature measurement

Function
Measure or Source
Voltage

Range or Type

Resolution

Accuracy

Notes

0 to 100 mV
725: 0 to 10V (source)
0 to 20V (source)
725/726: 0 to 30V (measure)
0 to 24

0.01 mV
0.001 V
0.001 V
0.001 V
0.001 mA

0.01%
0.02% Rdg + 2 LSD

Max load, 1 mA

0.01%; 0.02% Rdg
+2 LSD

Max load,
725/726: 1000Ω
725Ex: 250Ω

mV
(TC terminals)

-10.00 mV to +75.00 mV

0.01 mV

Ohms

15Ω to 3200Ω
5Ω to 4000Ω
2.0 to 1000 CPM
1 to 1100 Hz
1.0 to 10.0 kHz
10.0 to 15.0 kHz

0.01Ω to 0.1Ω
0.1 CPM
1 Hz
0.1 kHz
0.1 kHz

0.01%
0.02% of range +
1 LSD
0.10Ω to 1.0Ω
0.015%
±0.05%
±0.05%
±0.25%
±0.05%

mA

Hz - CPM

M used as S
M or S

M = Measure S = Source/Simulate
Unique 726 features are in bold
725Ex: ATEX cerfified
(Ex ATEX II IG EEX 1a IIB 171°C)

Included Accessories
TL75 Test Leads, AC72 Test Clips, one pair
of stackable test leads, user’s Manuals on
CD-ROM (725Ex also includes CCD control
drawing, Statement of Quality Assurance
Practices, NIST Traceable calibration
certificate)

Specifications

Unique 726 features are in bold

Loop Supply

N/A

10%

T/C

725/726: 24 V DC
725Ex: 12 V DC
J, K, T, E, L, N, U, XK

0.1 ºC, 0.1 ºF

T/C

B, R, S, BP

1 ºC, 1 ºF

RTDs

Cu (10), Ni 120 (672)
Pt 100, 200, 500, 1000 (385)
Pt 100 (3916),
Pt 100 (3926)

0.01 ºC
0.01 ºF

to 0.7 ºC
to 0.2 ºC
to 1.7 ºC
to 1.2 ºC
to 0.15 ºC

Maximum voltage: 30V
Operating temperature: 10°C to 55°C
Safety: CSA C22.2 No. 1010.1:1992
EMC: EN50082-1:1992 and EN55022:
1994 Class B

0.1 ºC, 0.1 ºF

Source;
5V p-p
1V - 20 V p-p
squarewave,
-0.1 V offset

to 0.2 ºC

Size (HxWxD): 200 mm x 96 mm x 47 mm
Weight: 0.65 kg
Battery: Four AA alkaline batteries.
Battery life: 25 hours typical; battery door
Warranty: Three years

Recommended Accessories
(Not for hazardous zones)

Ordering Information

94

Fluke 725
Multifunction Process Calibrator
Fluke 725Ex Intrinsically Safe Multifunction
Process Calibrator
Fluke 726
Precision Multifunction Process
Calibrator

C125
See page 118

TL220
See page 110

80PK-27
See page 116

TPAK
See page 120

700P27
See page 102

724 Temperature Calibrator
The temperature solution
The Fluke 724 Temperature Calibrator is
a powerful yet easy-to-use calibrator. Use
the measure and source functions to test
and calibrate almost any temperature
instrument.
• Easy to read dual display lets you view
input and output simultaneously
• Measure RTDs, thermocouples,
ohms, and volts to test sensors and
transmitters
• Source/simulate thermocouples, RTDs,
volts, and ohms to calibrate transmitters
• Perform fast linearity tests with 25% and
100% steps

• Execute remote tests with auto step and
auto ramp
• Power transmitters during test using
loop power supply with simultaneous
mA measurement
• Store frequently-used test setups for
later use

Features
Simultaneous Function
Capability
24.000 mA DC
24.000 mA DC with 24V loop
supply
100.00 mV DC
30.000V DC Measure
20.000V DC Measure 10.000V
DC Source
0 to 3200 Ohms
Thermocouple J, K, T, E, R, S, B,
L, U, N
RTD Ni120; Pt100 (3926); Pt100
(JIS); Pt100, 200, 500, 1000 (385)

Fluke 724

M = Measure

Channel A

Channel B

M
M
M or S
M
M or S
M or S
M or S
M or S

S = Source/Simulate

Specifications
Function
Measure or Source
Voltage

Range

Resolution

Accuracy

Notes

0 to 100 mV

0.01 mV

0.02% Rdg + 2 LSD

Max load, 1 mA

mA (measure)

0 to 10V (source)
0 to 30V (measure)
0 to 24 mA

0.001 V
0.001 V
0.001 mA

0.02% Rdg +2 LSD

Max load,
1000Ω

mV

-10.00 mV to +75.00 mV

0.01 mV

Resistance

0Ω to 3200Ω (measure)
15Ω to 3200Ω (source)
24V DC
J, K, T, E, L, N, U
B, R, S
Ni120 (672)
Pt 100, 200, 500, 1000 (385)
Pt 100 (3916)
Pt 100 (3926)

Loop Supply
Thermocouples
Thermocouples
RTDs

Included Accessories
TL75 Test Leads, AC72 Test Clips, one pair of
stackable test leads.

Maximum voltage: 30V
Operating temperature: -10°C to 55°C
Safety: CSA C22.2 No. 1010.1:1992
EMC: EN50082-1:1992 and EN55022:
1994 Class B

0.01Ω to 0.1Ω

0.025% of range +
1 LSD
0.10Ω to 1.0Ω

N/A
0.1 ºC
1 ºC
0.1 ºC

10%
to 0.7 ºC
to 1.4 ºC
to 0.2 ºC

Size (HxWxD): 200 mm x 96 mm x 47 mm
Weight: 0.65 kg
Battery: Four AA alkaline batteries
Battery life: 25 hours typical; battery door
Three Year Warranty

Ordering Information
Fluke 724

Temperature Calibrator

Recommended Accessories

C25
See page 118

TL220
See page 110

TL81A
See page 109

80PK-25
See page 116

80PK-3A
See page 116

95

712/714 Temperature Calibrators
The clear choice
The Fluke 710 Series Process Calibrators
offer clear new choices in single-function
calibrators. Whatever you want to
measure - temperature, pressure or basic
electrical parameters - you’ll find one of
these easy-to-carry handheld tools gives
you exactly the functions you need. They
combine the rugged, ready-for-action
package of the proven Fluke 80 Series
DMMs with the easy-to-use pushbutton
operation of the multifunction Fluke 740
Series Documenting Process Calibrators.
These calibrators are EMI tolerant,
dust and splash resistant, and have a
removable battery door for quick battery
changes.

Fluke 714

712 RTD Calibrator
• Measure temperature from RTD output
• Simulate RTD output
• Rosemount pulsed RTD transmitter
compatible
• Operates with seven types of RTDs
• Measure additional RTDs using Ohms
measurement function
• Simulate additional RTDs using Ohms
source function
• °F or °C selectable
• Four shrouded banana jacks

714 Thermocouple Calibrator
• Measure temperature from TC output
• Simulate TC output
• Operable with nine types of
thermocouples
• Calibrate linear TC transmitter with
mV source function
• Selectable °F or °C
• Thermocouple mini-jack termination
• Available as accessories; Fluke 700 TC1
and TC2 Thermocouple Mini-plug Kits

Fluke 712

Specifications
Model
Fluke 712

Fluke 714

Function
Measure/
simulate RTD

Range
-200 to 800ºC
(Pt 100)

Resolution
0.1ºC, 0.1ºF

Accuracy
0.33ºC, 0.6ºF
(Pt 100)

Measure/
simulate
Resistance
Measure/
simulate
Thermocouple

15 Ω to 3200 Ω

0.1 Ω

0.1 Ω to 1 Ω

-200 to 1800ºC,
depending on
type (K, -200 to
1370ºC)
-10 to 75 mv

0.1–C or ºF
(1ºC or ºF; BRS)

0.3ºC to 10 μV

0.01 mV

0.025% +
1 count

Measure/
simulate mV

Included Accessories
Yellow Holster (H80M excl. TPAK), TL75 Test
Leads and AC72 Alligator Clips (excluding
model 714), single 9V alkaline battery and
Instruction Sheet (14 languages)

Maximum voltage: 30 V
Operating temperature: -10°C to 55°C
Safety: CSA C22.2 No. 1010.1:1992
EMC: EN50082-1:1992 and EN55022:
1994 Class B

Notes
Pt; 100, 200, 500,
1000 (385);
Pt 100 (3926);
Pt 100 (3916) JIS;
Ni 120 (672)

9 TC types:
J K T E R S B per NIST
175 and ITS-90, L U per
DIN 43710 and IPTS-68

Size (HxWxD): 201mm x 98 mm x 52 mm
Weight: 0.6kg
Battery: 9V alkaline
Battery Life: 4 to 20 hours, typical, depending
on functions used
Three Year Warranty

Ordering Information
Fluke 712
Fluke 714

RTD Calibrator
Thermocouple Calibrator

Recommended Accessories

C25
See page 118

96

C550
See page 118

TL970
See page 109

TL220 (714)
See page 110

80PK-24 (714)
See page 116

9140 Series Field Metrology Wells
4180 Series Infrared Calibrators
Field Metrology Wells and infrared
calibration targets

Fluke 9142/9143/9144

9142, 9143, 9144
Field temperature calibration with
precision and speed

4180/4181 IR Calibrators
True metrology solution for infrared
Calibration

The Fluke 9140 series Field Metrology
Wells extend high performance portable
temperature calibration to the industrial
process environment by maximizing
portability, speed, and functionality
with little compromise to metrology
performance.

Now it’s easy to increase your IR
temperature measurement accuracy in
the lab or the field with the new 4180/81
Precision Infrared Calibrators from Fluke’s
Hart Scientific division.

Offering a broad temperature covered by
three models you can easily cover varied
contact temperature probe workloads
between -25 ºC to 660 ºC.
They are quick to reach temperature set
points, yet they are stable, uniform, and
accurate. These industrial temperature
calibrators are perfect for performing
transmitter loop calibrations, comparison
calibrations, or simple checks of
thermocouple sensors.
Adding the process option means there is
no need to carry additional tools into the
field. The optional built-in two-channel
readout measures resistance, voltage, and
4–20 mA current with 24V loop power.
Fluke 4180/4181

• Lightweight, portable, and fast
• Cool to –25 °C in 15 minutes and heat to
660 °C in 15 minutes
• Built-in two-channel readout for PRT,
RTD, thermocouple, 4-20 mA current
• On-board automation and
documentation
• Metrology performance in accuracy,
stability, uniformity, and loading

Included Accessories

914x: 9930 Interface-it Software, Report of
Calibration, Test leads (P Version Only),
6-pin DIN Connector for Reference Probe
(P Version Only)

Their accredited calibrations from Hart’s
IR laboratory help to ensure traceable,
consistent measurements accurate to
+0.25 ºC. Select from eight preconfigured
Fluke thermometer settings or set up your
own.
The large 152 mm (6 inch) target helps
eliminate errors. So whether you’re
measuring from -15 ºC to 120 ºC (4180)
or from 35 ºC to 500 ºC (4181) you’ll get
a 4:1 TUR.
• High performance, designed for
industrial use
• Guaranteed accuracy specifications
• Excellent stability and uniformity
• Large 152 mm targets capture peripheral
vision of IR thermometer
• Portability and speed for field use including convenient bail handle
• Simulates individual IR thermometer
emissivity settings
• No difficult infrared calculations
• Fluke and Raytek thermometer
calibration points can be loaded directly
into the calibrator for convenience
• Calibrated in accredited infrared
laboratory by Hart Scientific, the experts
in temperature calibration
• At least 4 times more accurate than
most IR thermometers
• Calibration includes uncertainties from
surface heat loss and emissivity

Ordering Information
Fluke 4180

Precision Infrared
Calibrator, –15 °C to 120 °C
Fluke 4181
Precision Infrared
Calibrator, 35 °C to 500 °C
Fluke 4180-CASE Carrying Case, 4180, 4181
Fluke 4180-DCAS Carrying Case with wheels,
4180, 4181
Fluke 9142-X
Fluke 9143-X
Fluke 9144-X

Field Metrology Well,
Low Temp
Field Metrology Well,
Mid Temp
Field Metrology Well,
High Temp

Add -P to order optional Process option
(914X-X-P). X represents insert type,
A, B, C, D, E or F

Specifications
9142

9143

9144

4180

Temp Range

–25 °C to 150 °C

33 °C to 350 °C

50 °C to 660 °C

–15 °C to 120 °C

35 °C to 500 °C

Stability

±0.01 °C Full Range

±0.2 °C at 250 °C

±0.01 °C Full Range

±0.1 °C at 0 °C

±0.1 °C at 35 °C

Target Size
diameter
Emissivity
Range
NIST
Accredited
Calibration

N/A

±0.03 °C at 50 °C
±0.04 °C at 420 °C
±0.05 °C at 660 °C
±0.02 °C at 50 °C
±0.05 °C at 420 °C
±0.15 °C at 660 °C
N/A

±0.05 °C at 0 °C

Uniformity

±0.02 °C at 33 °C
±0.02 °C at 200 °C
±0.03 °C at 350 °C
±0.01 °C at 33 °C
±0.015 °C at 200 °C
±0.02 °C at 350 °C
N/A

152.4 mm

N/A

N/A

N/A

152.4 mm
diameter
Preset to 0.95

YES

YES

YES

YES

YES

9142/9143/9144:
Size (HxWxD): 290 x 185 x 295 mm
Weight: 9142: 8.2 kg, 9143: 7.3 kg, 9144: 7.7 kg
One Year Warranty

4181

Preset to 0.95

4180/4181
Size (HxWxD): 241 x 356 x 241 mm
Weight: 4180: 9.1 kg, 4181: 9.5 kg
One Year Warranty

For the complete line of Fluke heat sources
check the Fluke web at www.fluke.eu

97

717/718/718Ex/719
Pressure Calibrators
Pump up the pressure

Fluke 719

Fluke 717

717 Pressure Calibrators

718 Pressure Calibrators

• Measure pressure, 0.05% of full scale
with internal sensor
- 1/8 NPT pressure fitting
- Compatible with non-corrosive gasses
and liquids
• Pressure measurement to 700 bar
using any of the Fluke-700Pxx Pressure
Modules
• Wide range of selectable measurement
units for pressure
• Current measurement with 0.015%
accuracy and 0.001mA resolution
• Simultaneous pressure and current
measurement for easy P/I testing
• 24 volt loop power supply
• Zero, Min-Max, Hold and Damping
functions
• Pressure switch test captures set, reset
and deadband values

Same features as Fluke 717 plus:
• Newly designed built-in pressure/
vacuum hand pump with vernier and
bleed valve helps protect the pump from
damage and is easier to clean
For 718Ex Intrinsically Safe Pressure
Calibrator see chapter on Ex products in
this catalog.

719 Electric Pressure Calibrator
Same features as Fluke 717 plus:
• Electric pump for one handed operation
• mA source for calibrating I/P devices
and 4-20 mA I/O
• Best in class pressure measurement
accuracy of 0.025%

Specifications

Fluke 718Ex

Fluke 718

Included Accessories
Fluke 717, 718, 718Ex and 719:
Yellow Holster (718Ex red holster), TL75 Test
leads, AC72 Alligator Clips, Single 9V alkaline
battery (two 9V batteries in 718 and 719), User
manual on CD ROM.
719 also includes: Push fit connectors,
Translucent test hose.

Ordering Information
Fluke 719 30G
Fluke 719 100G
Fluke 718 1G
Fluke 718 30G
Fluke 718 100G
Fluke 718 300G
Fluke 718Ex 30G

98

Electric Pressure Calibrator
Electric Pressure Calibrator
Pressure Calibrator
Pressure Calibrator
Pressure Calibrator
Pressure Calibrator
Intrinsically Safe Pressure
Calibrator
Fluke 718Ex 100G Intrinsically Safe Pressure
Calibrator
Fluke 717 1G
Pressure Calibrator
Fluke 717 30G
Pressure Calibrator
Fluke 717 100G
Pressure Calibrator
Fluke 717 300G
Pressure Calibrator
Fluke 717 500G
Pressure Calibrator
Fluke 717 1000G Pressure Calibrator
Fluke 717 1500G Pressure Calibrator
Fluke 717 3000G Pressure Calibrator
Fluke 717 5000G Pressure Calibrator

Model
719 30G
719 100G
718 1G
718 30G
718 100G
718 300G
717 1G
717 30G
717 100G
717 300G
717 500G
717 1000G
717 1500G
717 3000G
717 5000G

Range
-850 mbar to 2.4 bar
-850 mbar to 8 bar
-68.9 mbar to 68.9 mbar
-850 mbar to 2 bar
-850 mbar to 7 bar
-850 mbar to 20 bar
-68.9 mbar to 68.9 mbar
-850 mbar to 2 bar
-850 mbar to 7 bar
-850 mbar to 20 bar
0 mbar to 34.5 bar
0 mbar to 69 bar
0 bar to 103.4 bar
0 bar to 207 bar
0 bar to 345 bar

Resolution
0.1 mbar
1 mbar
0.001 mbar
0.1 mbar
0.1 mbar
1 mbar
0.001 mbar
0.1 mbar
0.1 mbar
1 mbar
1 mbar
1 mbar
0.01 bar
0.01 bar
0.01 bar

Over Pressure
Over pressure 2xFS
Over Pressure 2xFS
Over Pressure 5xFS
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 375 PSI, 25 bar
Over Pressure 5xFS
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 375 PSI, 25 bar
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 2xFS

For Fluke 717/718/719 models: Supported Pressure Units; psi, in. H 2O(4°C), in. H2O(20°C), cm
H2O(4°C), cm H2O(20°C), bar mBar, kPa, inHg, mmHg, kg/cm2
Functions: Zero, Min, Max, Hold, Damp functions
Max. Voltage: 30 V
Operating temperature: -10°C to 55°C
Safety: CSA C22.2 No. 1010.1:1992
EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke 717: For use with non corrosive gasses and liquids
Fluke 718/719: For use with non corrosive gasses
717
Size (HxWxD): 201 mm x 98 mm x 52 mm
Weight: 0.6 kg
Three Year Warranty

719
Size (HxWxD): 210 mm x 87 mm x 60 mm
Weight: 0.912 kg
Three Year Warranty (Pump one year)

718/718Ex
Size (HxWxD): 216 mm x 94 mm x 66 mm
Weight: 0.992 kg
Warranty: Three years

Recommended Accessories
(Not for hazardous zones)

C43 (718)
See page 118

C125 (717)
See page 118

TL220
See page 110

700P27
See page 102

700 LTP-1
See page 102

705/707/707Ex/715
Loop Calibrators
4-20 mA, source, measure, simulate
705 Loop Calibrator

715 Volt/mA Calibrator

• Simultaneous mA and %
• mA accuracy of 0.02%
• Measure, source and simulate mA
• Push button 25% steps for fast, easy
linearity checks
• “Span Check” for fast confirmation of
zero and span
• Selectable slow ramp, fast ramp, and
step function
• 24 volt internal loop supply
• 0 - 20 mA or 4 - 20 mA default start up
modes

• Measure loop current (0-20 mA,
4-20 mA) signals with 0.015% accuracy
and 0.001 mA resolution
• Measure voltage output process signals
from PLCs, transmitters
• Source or simulate 24 mA loop current
• Source voltage to 100 mV or 10 V
• 24 V loop supply with simultaneous
current measurement

707 Loop Calibrator

Fluke 705

Fluke 715

• Features of the Fluke 705
• “Quick Click” detented rotary knob for
one handed operation
• Higher accuracy: 0.015%
• Mains Voltage Input protection
• 250 Ohm loop resistance for with Hart
instrumentation

707Ex Intrinsically Safe Loop
Calibrator
• Same features as Fluke 707
• For use in explosion endangered areas
• ATEX certified ( II 2 G Eex ia IIC T4)

Specifications
Functions
Voltage measurement
Range
Resolution
Accuracy

Current measurement
Range
Resolution
Accuracy
Fluke 707

Current sourcing
Range
Accuracy
Drive capability
Fluke 707Ex
Loop power while measuring mA
Voltage sourcing
Display current and % of span
Auto step, auto ramp
Span Check
1

705/707/707 Ex

715

0-28 V DC
1 mV
705: 0.025% Rdg + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD

0-200 mV, 0-20 V
10 μV 1 mV
0.01% Rdg + 2 LSD

0-24 mA
0.001 mA
705: 0.025% Rdg + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD

0-24 mA
0.001 mA
0.015%

0-20 mA or 4-20 mA1
705: 0.025% Rdg + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD
705: 1000 Ω @ 24 mA
707: 1200 Ω @ 24 mA
707Ex: 700 Ω 20 mA
24 V
N/A
Yes
Yes
Yes

0-20 mA or 4-20 mA1
0.015% + 2 LSD
1000 Ω @ 24 mA
24 V
0-100 mV or 0-10 V
mA or %
Yes
Yes

will over-range to 24 mA

Included Accessories
Fluke 705/707: C10 Yellow Holster, TL75 Test
Leads, AC72 Alligator Clips, Single 9V alkaline
battery, Instruction Sheet
Fluke 707Ex: Red Ex-holster, Fluke TL75 Test
Leads, AC72 Alligator Clips, Single 9V alkaline
battery, Instruction Sheet
Fluke 715: Yellow Holster (H80M excl. TPAK),
TL75 Test Leads and AC72 Alligator Clips,
Single 9V alkaline battery, Instruction Sheet

Fluke 705, 707, 707Ex

Maximum voltage: 30 V (28 V - 707Ex)
Operating temperature: -10 to 55°C
Safety: CSA C22.2 No. 1010.1: 1992
EMC: EN50082-1:1992 and EN55022: 1994 Class B
Size (HxWxD): 164 mm x 75 mm x 47 mm;
Weight: 0.35 kg
Battery: One 9 V alkaline
Battery life: 18 hours typical, at 12 mA
Three Year Warranty

715

Size (HxWxD): 201 mm x 98 mm x 52 mm
Weight: 0.6 kg
Battery: One 9V alkaline
Battery life: 4 to 20 hours
Three Year Warranty

Ordering Information
Fluke 705
Fluke 707
Fluke 707Ex
Fluke 715

Loop Calibrator
Loop Calibrator
Intrinsically Safe Loop Calibrator
Volt/mA Calibrator

C12A (705/707)
See page 118

C25 (715)
See page 118

TL220
See page 110

TP920
See page 109

T PAK (715)
See page 120

99

771, 772 and 773
mA Process Clamp Meters
mA measurements without breaking the loop.
Save time. Save money.
Fluke 771, 772 and 773

Fluke 773

• Measure 4 to 20 mA signals without
”breaking the Loop,” save time and
money troubleshooting 4 to 20 mA
signals

• DC voltage measurement to verify 24 V
power supplies or voltage I/O signals
• Source dc voltage to test voltage input
devices
• Scaled mA output signal enables a
logging DMM (289) to record 4 to 20 mA
signal without breaking the loop
• mA in/out: simultaneously source a mA
signal while measuring a mA signal
with the clamp

Fluke 772 and 773
• Source 4 to 20 mA signals for testing
control system I/O or I/Ps
• Simulate 4 to 20 mA signals for testing
control system I/O
• Measure 4 to 20 mA signals with incircuit measurement
• Power a transmitter with the 24 V loop
power supply
• Automatically ramp and step change
the 4 to 20 mA output for remote
testing

Fluke 771

Features

Fluke 772

New

771
O

mA measure w/jaw
mA measure In circuit
mA source
mA sim
Loop power 24 V
DCV source 0-10 V
DCV measure 0-30 V
Scaled mA output to mA input
mA in/out

771, 772, 773
772 and 773

Fluke 771: soft carrying case and user’s manual
Fluke 771 + 772: plus TL75 test leads, AC72
alligator clip set and TL940 mini-hook test
lead set

Ordering Information
Fluke 771
Fluke 772
Fluke 773

100

Milliamp Process Clamp Meter
Milliamp Process Clamp Meter
Milliamp Process Clamp Meter

773
O
O
O
O
O
O
O
O
O

Specifications

Fluke 773

Included Accessories

772
O
O
O
O
O

Function
mA measurement

Resolution and range
0 to 20.99 mA
21.0 mA to 100.0 mA

Accuracy
0.2 % + 5 counts
1 % + 5 counts

mA measurement

0 to 24.00 mA

0.2 % + 2 counts

772 and 773

mA source

0 to 24.00 mA

0.2 % + 2 counts

772 and 773

mA simulate

0 to 24.00 mA

0.2 % + 2 counts

773

Voltage source

0 to 10.00 V dc

0.2 % + 2 counts

773

Voltage measure

0 to 30.00 V dc

0.2 % + 2 counts

Size (HxWxD):
771: 212 mm x 59 mm x 38 mm
772 + 773: 248 mm x 76 mm x 41 mm
Weight: 771: 0.26 kg
772 + 773: 0.42 kg
Battery: 771: 2x 1.5V Alkaline, IEC LR6
772 + 773: 4x 1.5V Alkaline, IEC LR6

Notes
Measured by clamp
Measured in series
with test jacks
Maximum mA drive:
24 mA into 1,000 ohms
Maximum voltage
50 V dc
2 mA maximum
drive current

Battery Life: 771: 20 hours typical
772 + 773: 12 hours @ 12 mA source into
500 ohms
IP Rating: IP 40
Warranty: 3 years, 1 year on mA clamp
accessory and cable

787/789 ProcessMeters
Double your power
The Fluke 787 and 789 ProcessMeters
combine a Digital Multimeter and a Loop
Calibrator in one rugged handheld tool,
giving process technicians double the
power.
The Fluke 789 has a built-in 24 V loop
supply which reduces the need for
taking a separate power supply when
doing offline transmitter testing. The
IR communication port of the Fluke
789 allows data to be logged to optional

FlukeView Software for graphical analysis
and reporting.

Features

Fluke 787

Fluke 789

787
O
O
O

DMM and Loop Calibrator in one tool
Precision 1000 V, 440 mA True RMS Digital Multimeter
DC current source and Loop Calibrator
24 V Loop power supply
Min/Max / Average / Hold / Relative Modes
Diode Test and Continuity Beeper
Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
Simultaneous mA and % of scale read-out
Externally accessible battery / fuses
HART mode setting with loop power and a built-in 250 Ω resistor
0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span check
Infrared I/O serial port

O
O
O
O
O/-

789
O
O
O
O
O
O
O
O
O/O
O
O
O

Specifications
787

True RMS

Included Accessories
787: Yellow Holster (H80M excl. TPAK), TL75
Hard Point Test Lead Set plus AC72 Alligator
Clips, one 9V battery, user manual
789: TL71 Test Lead Set plus AC72 Alligator
Clips, four 9V AA alkaline batteries, user
manual and quick reference guide.

Ordering Information
Fluke 787
Fluke 789
FVF-SC2

ProcessMeter
ProcessMeter
FlukeView Forms Software
including interface cable

Voltage measurements
Range
Resolution
Accuracy
Current measurement
Range
Resolution
Accuracy
Current Sourcing
Range
Accuracy
Other specifications
Max drive capability
Loop power
Resistance measurement
Frequency
Continuity
Span Check

789

0-1000 V AC or DC
0.1 mV to 1.0 V
0.1% Rdg+1 LSD (V DC)

0-1000 V AC or DC
0.1 mV to 1.0 V
0.1% Rdg+1 LSD (V DC)

0-1 A
1 mA
0.2%+2 LSD

0-1 A
1 mA
0.2%+2 LSD

0-30 mA
0.001 mA
0.05%+2 LSD

0-30 mA
0.001 mA
0.05%+2 LSD

0-20 mA or 4-24 mA
0.05% of span

0-20 mA or 4-24 mA
0.05% of span

500 Ω
N/A
To 40 MΩ, 0.2%+1 LSD
To 19.999 kHz, 0.005%+1 LSD
Beeps for resistance < 100 Ω
No

1200 Ω
24 V
To 40 MΩ, 0.2%+1 LSD
To 19.999 kHz, 0.005%+ LSD
Beeps for resistance < 100 Ω
Yes

Maximum voltage: 1000 V
Operating temperature: -20 to 55ºC

787

Size (HxWxD): 201 mm x 98 mm x 52 mm
Weight: 0.642 kg
Battery: One 9 V alkaline
Battery life: 12 to 50 hours typical
Three Year Warranty

789

Size (HxWxD): 203 mm x 100 mm x 50 mm
Weight: 0.6 kg
Battery: Four AA alkaline batteries
Battery life: 14 to 140 hours typical
Three Year Warranty

Recommended Accessories

C125
See page 118

TL220
See page 110

80T-150U
See page 116

i400
See page 114

i410
See page 115

101

Field Calibrator Accessories
Fluke 700 Series Pressure Modules
• Ranges from 2.5 mbar to 700 bar.
• Gage, differential, dual (compound),
absolute and vacuum modules
• Very high accuracy: up to 0.025% FS
• Full-accuracy performance for 0°C to 50°C
• Pressure readings update twice per
second, and may be displayed in up to 11
different units

Model
Differential
700P00
700P01/700P01Ex
700P02
700P22
700P03
700P23
700P04
700P24/700P24Ex
Gage
700P05/700P05Ex
700P06/700P06Ex
700P27/700P27Ex
700P07
700P08
700P09/700P09Ex
Absolute
700PA3
700PA4/700PA4Ex
700PA5
700PA6
Vacuum
700PV3
700PV4
Dual
700PD2
700PD3
700PD4
700PD5
700PD6
700PD7
High
700P29/700P29Ex
700P30
700P31

• Compatible with Fluke 717, 718, 725 and
74x series.
• Rugged cases protect the modules from
harsh environments
• All modules include NIST traceable
certificate and test data
• ATEX certified Ex versions available
( II 1 Eex ia IIB T4)

Range (approx.)

Resolution
uncertainty
(23 ± 3°C) (FS)

Reference

High side media

Low side media

Fitting material

Max
overpressure2)

2.5 mbar
25 mbar
70 mbar
70 mbar
340 mbar
340 mbar
1000 mbar
1001 mbar

0.001 mbar
0.01 mbar
0.007 mbar
0.007 mbar
0.01 mbar
0.01 mbar
0.1 mbar
0.1 mbar

0.3 %
0.2 %
0.15 %
0.1 %
0.05 %
0.025 %
0.025 %
0.025 %

Dry 1)
Dry
Dry
316 SS
Dry
316 SS
Dry
316 SS

Dry
Dry
Dry
Dry
Dry
Dry
Dry
Dry

316 SS
316 SS
316 SS
316 SS
316 SS
316 SS
316 SS
316 SS

30x
3x
3x
3x
3x
3x
3x
3x

2 bar
7 bar
20 bar
34 bar
70 bar
100 bar

0.1 mbar
0.7 mbar
1 mbar
1 mbar
7 mbar
10 mbar

0.025 %
0.025 %
0.025 %
0.025 %
0.025 %
0.025 %

316 SS
316 SS
316 SS
316 SS
316 SS
316 SS

N/A
N/A
N/A
N/A
N/A
N/A

316 SS
316 SS
316 SS
316 SS
316 SS
316 SS

3x
3x
3x
3x
3x
2x

340 mbar
1000 mbar
2 bar
7 bar

0.01 mbar
0.1 mbar
0.1 mbar
0.7 mbar

0.05 %
0.05 %
0.05 %
0.05 %

316 SS
316 SS
316 SS
316 SS

N/A
N/A
N/A
N/A

316 SS
316 SS
316 SS
316 SS

3x
3x
3x
3x

-340 mbar
-1000 mbar

0.01 mbar
0.1 mbar

0.04 %
0.04 %

316 SS
316 SS

Dry
Dry

316 SS
316 SS

3x
3x

± 70 mbar
± 340 mbar
±1000 mbar
-1000/+2000 mbar
-1000 mbar/+6.9 bar
-1000 mbar/+13.8 bar

0.007 mbar
0.01 mbar
0.1 mbar
0.1 mbar
1 mbar
1 mbar

0.15 %
0.04 %
0.025 %
0.025 %
0.025 %
0.04 %

316 SS
316 SS
316 SS
316 SS
316 SS
316 SS

Dry
Dry
Dry
N/A
N/A
N/A

316 SS
316 SS
316 SS
316 SS
316 SS
316 SS

3x
3x
3x
3x
3x
3x

200 bar
340 bar
700 bar

0.01 bar
0.01 bar
0.07 bar

0.05 %
0.05 %
0.05 %

C276
C276
C276

N/A
N/A
N/A

C276
C276
C276

2x
2x
1.5x

1)“Dry” indicates dry air or non-corrosive gas as compatible media. “316 S S” indicates media compatible with Type 316 Stainless Steel. “C276” indicates media compatible with Hastelloy C276.
2)Maximum overpressure specification includes common mode pressure.

Other accessories
700LTP-1 Low-pressure Test Pump

700HTH-1 Hydraulic Test Hose

• For low pressure applications
• Vacuum to -13 psi / -.90 bar
• Pressure to 100 psi / 6.9 bar
• With fine-control, adjustable relief valve
and slow bleed capability

• Hydraulic test hose is a 10,000 psi, 690 bar

700PTP-1 Pneumatic Test Pump-1
• Handheld pressure pump
• Pressures up to 600 psi, 40 bar

700HTP-1 Hydraulic Test Pump
• Pressures up to 10,000 psi/690 bar.
Fluke 700LTP-1

102

Fluke 700PTP-1

700PRV-1 Pressure Relief Valve
• Pressure relief valve for 700HTP-1
• Adjustable from 725 to 5800 PSI (50 to 200
bar)

700ILF In-Line Filter for the
Fluke 718
700PCK Pressure Module
Calibration Kit
BP7235 NiMH Battery Pack
BE9005 Battery Eliminator

Vibration Tester
With the Fluke 810 Vibration Tester you will be able to control unplanned
downtime, prevent recurring problems, set repair priorities and manage
your resources with an entirely new approach to vibration testing. In three
quick, easy steps, the new Fluke 810 helps you locate and diagnose common mechanical problems and prioritize their repair actions. The combination of powerful algorithms and a database of real-world measurement
experience make the Fluke 810 the most advanced troubleshooting tool
for mechanical maintenance teams who need an answer now.

103

810 Vibration Tester
New
Motor diagnosis and repair in three simple steps
The Fluke 810 Vibration Tester is the
most advanced troubleshooting tool
for mechanical maintenance teams
who need an answer now. The unique
diagnostic technology helps you quickly
identify and prioritize mechanical
problems, putting the expertise of a
vibration analyst in your hands.

Use the vibration tester to:

Fluke 810

Set-up

• Troubleshoot problem equipment and
understand the root cause of failure
• Survey equipment before and after
planned maintenance and confirm the
repair
• Commission new equipment and
ensure proper installation
• Provide quantifiable proof of equipment
condition and drive investment in
repair or replacement
• Prioritize and plan repair activities and
operate more efficiently
• Anticipate equipment failures before
they happen and take control of spare
parts inventories
• Train new or less-experienced
technicians and build confidence and
skill across the team

Measure

Features and benefits
• On-board identification and location of
the most common mechanical faults
(bearings, misalignment, unbalance,
looseness) focus maintenance efforts
on root cause, reducing unplanned
downtime
• Fault severity scale with four severity
levels help you prioritize maintenance
work
• Repair recommendations advise
technicians on corrective action
• On-board context sensitive help provide
real-time tips and guidance to new
users
• 2 GB expandable on-board memory
provide enough space for your
machinery’s data
• Self-test functions ensure optimal
performance and more time on the job
• Laser tachometer for accurate machine
running speed promotes confident
diagnoses
• Tri-axial accelerometer reduces
measurement time by 2/3 over single
axis accelerometers
• Viewer PC Software expands data
storage and tracking capacity
• Color LCD display and intuitive
multilingual, icon-based user interface
promote use right out of the box

Specifications
(Check the Fluke web for detailed specifications)

Diagnose

Language support:
eng, ger, fre, ita, spa, por

Included Accessories
Tri-axial TEDS accelerometer, accelerometer
magnet mount, accelerometer mounting
pad kit with adhesive, accelerometer quick
disconnect cable, laser tachometer and
storage pouch, smart battery pack with cable
and adapters, shoulder strap, adjustable
hand strap, Viewer PC application software,
mini-USB to USB cable, getting started guide,
illustrated quick reference guide, users
manual CD-ROM, instructional training CDROM, hard carrying case.

Ordering Information
104

Fluke 810

Vibration Tester

Diagnostic specifications
Standard faults
Unbalance, looseness, misalignment and bearing failures
Analysis for
Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps,
piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/
lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed
coupled machines, spindles
Machine rotational
200 rpm to 12000 rpm
speed range
Diagnosis details
Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details,
cited peaks, spectra
Electrical specifications
Ranging
Automatic
A/D converter
4 channel, 24 bit
Usable bandwith
2 Hz to 20 kHz
Sampling
51.2 kHz
Digital signal
Automatically configured anti-alias filter, high-pass filter, decimation, overlapping,
processing functions windowing, FFT, and averaging
Sampling rate
2.5 kHz to 50 kHz
Dynamic range
128 dB
Amplitude accuracy
±0.1 dBV
FFT resolution
800 lines
Spectral windows
Hanning
Frequency units
Hz, orders, cpm
Amplitude units
in/sec, mm/sec, VdB (US), VdB (Europe)
Non-volatile nemory SD micro memory card, 2 GB internal + user accessible slot for additional storage

Battery type: Lithium-ion, 14.8 V 2.55 Ah
Size (HxWxD): 186 x 267 x 70
Weight: 1.9 kg

Warranty: Three years on tester
One year on sensor and tachometer

ATEX Certified Test Tools
The Fluke line of intrinsically safe tools is designed to meet the needs of
technicians working in and around hazardous areas. The tools are ideal
for environments in chemical plants, petro-chemical plants, oil platforms, refineries and other locations where risk of explosion exists. The
products are easily recognizable from standard Fluke products by their
lighter grey colour and red holster.

105

A brief look at ATEX
Intrinsic safety is a protection standard
employed in potentially explosive
atmospheres. Devices that are certified
as “intrinsically safe” are designed to be
unable to release sufficient energy, by
either thermal or electrical means, to cause
ignition of flammable material (gas, dust/
particulates).

What is “Intrinsically Safe”?
Intrinsically safe standards apply to all
equipment that can create one or more
of a range of defined potential explosion
sources:
• Electrical sparks
• Electrical arcs
• Flames
• Hot surfaces
• Static electricity
• Electromagnetic radiation
• Chemical reactions
• Mechanical impact
• Mechanical friction
• Compression ignition
• Acoustic energy
• Ionizing radiation

What industries are intrinsically
safe products designed for?
• Petro-chemical
• Oil platforms and refineries
• Pharmaceutical
• Bulk materials (e.g. grain)
• Mining
• Pipelines
• Any environment where explosive gases
are present

What is ATEX?
The primary intrinsically safe standard has
been set in the European Union with the
9/94/EC Directive, commonly called ATEX
(“Atmosphères Explosibles,” French for
explosive atmospheres). The stated goal of
the guidelines is to “help ensure the free
movement of products in the European
Union” by “minimizing the number of
safeguard clause applications, at least those
originating from divergent interpretations
The ATEX rules have been in place as a
voluntary standard since 1 March 1996.
The rules are mandatory on electrical
and electronic equipment for use in
environments subject to explosion hazard
sold in the EU starting 1 July 2003. From

this date onwards, all products sold for
use in explosive atmospheres must have
ATEX certification and carry the distinctive
symbol:

The Fluke Ex (IS) product line
Fluke is among the first manufacturers to
produce handheld test tools according to
the latest ATEX standards. The Fluke line of
intrinsically safe tools is designed to meet
the needs of technicians working in and
around hazardous areas:
• Install, maintain and troubleshoot
equipment by using the new Fluke 87V Ex
Digital Multimeter
• Maintain and calibrate sensors,
transmitters and control loops with the
line of Ex field calibrators
The tools are ideal for environments
in petro-chemical plants, oil platforms,
refineries and other locations subject to risk
of explosion.
Apart from having the ATEX markings, the
visual difference between a standard Fluke
tool and the corresponding Ex version is
the different grey body colour and a red,
conductive holster designed specifically
to eliminate the potential for electrical
discharge.
Inside, the Fluke Ex tools have been
reengineered to reduce energy avoiding
generation of heat and electrical sparks.
They are premium products designed for
ultimate safety.
Making sense of ATEX certification
Fluke 707Ex is ATEX-compliant and is
certified
II 2 G EEx ia IIC T4— but what
exactly does that mean?

Here a brief explanation of the ATEX
certification designations.

ATEX certification 707Ex

II 2 G

EEx
ia
IIC
T4

106

The ATEX examination mark. This sign is required on all devices used in European hazardous
areas.
The classification of zones.
“II” designates the tool is approved for all non-mining areas.
“2” represents the category of the device, in this case the device is rated for the second most
hazardous areas.
“G” designates atmosphere, in this case gas, vapors and mist.
Explosion protection based on European Ex-regulations.
The type of protection from explosion, in this case the energy in a device or connector has
been reduced to a safe value.
Gas Group. “IIC” indicates compatibility with the most dangerous gas group.
Temperature class gives the user the maximum temperature of a surface that may be in
contact to the Ex atmosphere under fault conditions. T4 is rated at 135°C.

ATEX-certified Test Tools
Fluke intrinsically safe tools for tough measurement and
calibration tasks

Fluke 87V Ex Intrinsically safe
version of the world’s most popular
multimeter

Fluke 87V Ex

With its high performance, accuracy and
motor drive compatibility, the Fluke 87V
is the most popular industrial multimeter
around. Now Fluke has introduced a new
intrinsically safe version – the 87V Ex – for
measurements in and around hazardous
areas.
The Fluke 87V Ex has all the measurement
and troubleshooting functions of the proven
Fluke 87V. Unlike other ATEX-certified tools,
it can be used both inside and outside the
hazardous zone (ATEX Zones 1 & 2) without
compromising performance or compliance.
So there’s no need to carry different tools
for use in specific zones. It also has a builtin thermometer with TC probe, further
reducing technicians’ tool counts.
• ATEX safety rating II 2G EEx ia IIC T4
• EN61010-1 CAT III 1000V/CAT IV 600V
electrical safety rating

Fluke 707Ex Fast, one-handed tool for
loop checks
The Fluke 707Ex is the ideal, stand alone
tool for calibration and maintenance of 4
to 20 mA control loops. It provides 24V loop
power while measuring mA, and lets you
measure and source/simulate mA with 1 μA
resolution.
• ATEX safety rating
II 2G EEx ia IIC T4
See also page 99

Fluke 707Ex

Fluke 718Ex Self-contained Pressure
Calibrator
The Fluke 718Ex offers a convenient,
self contained solution for pressure
measurements and calibration. With its
internal pressure sensor and pump, it’s
ready for immediate, stand alone use. The
pressure range can easily be extended to up
to 200 bar with any of the 8 Fluke 700PEx
Pressure Modules.
• ATEX safety rating
II IG EEx ia IIC T4

See also page 17

See also page 98

Fluke 725Ex Intrinsically safe
Multifunction Process Calibrator
The Fluke 725Ex intrinsically safe
Multifunction Process Calibrator is powerful
yet easy-to-use. Combined with the
Fluke 700PEx Pressure Modules, the 725Ex
is able to calibrate almost any process
instrument likely to need service in any
area where explosive gases may be present.
• ATEX safety rating
II IG EEx ia IIB 171°C

Fluke 718Ex

Fluke 700Ex Pressure Modules

See also page 94

Fluke 725Ex
Fluke 700Ex

These intrinsically safe pressure
modules for use with the Fluke 725Ex
Multifunctional Process Calibrator and
Fluke 718Ex Pressure Calibrator cover the
most commonly used pressure calibration
ranges from 0-25 mbar and 0-200 bar.
There’s a choice of 8 gage, differential and
absolute modules.
• ATEX safety rating
II 1G EEx ia IIC T4
See also page 102

107

General Accessories
The best test tools deserve accessories designed and manufactured
to the same high quality and safety standards. So we also provide a
comprehensive range of test leads, probes and clips, current clamps,
temperature accessories and dedicated electronic and automotive
accessories. And to protect your valuable instrument, choose a rugged
Fluke tailor-made holster or case.

108

Electronic Test Leads,
Probes & Clips

Test Leads

Test Leads / Patch Cords

TL910 Electronic Test Lead Set

TL960 Micro-Hook Test Lead Set

TP920 Test Probe Adapter Kit

• Very small 1 mm tips to access hard
to reach test points
• Probe tip length up to
100 mm, test lead length:
1m
• Included: 3 sets of
spring loaded gold tips
and 2 sets of stainless steel tips
• CAT IV 600 V, CAT III 1000 V,
3 A rating

• 1 pair (red, black) of test leads with
multi-stacking 4 mm banana
plugs and micro-hooks
• Micro-hooks attach to
component leads up to 1 mm
diameter
• 90 cm long PVC insulated leads
• 30 V rms or 60 V DC, 15 A

• Set of push-on adapters for TL71 and TL75
test probes
• IC test adapters,
extended probe tips,
medium alligator clips
(max.opening
7.6 mm)
• CAT II 300 V, 5 A rating

TL930 Patch Cord Set (60 cm)

TL970 Hook and Pincer Kit

• 1 pair (red, black)
multi-stacking 4 mm banana plug
patch cords
• Nickel-plated banana
plugs
• 61 cm long
PVC insulated leads
• 30 V rms or 60 V DC, 15 A

• TL940 Mini-Hook Test Lead Set
• TL950 Mini-Pincer Test Lead
Set
• TL960 Micro-Hook Test Lead
Set

TP912 Replacement Tips for TL910
• Replacement tips for TL910
• Five sets of gold plated and stainless
steel tips

TL40 Retractable Tip Test Lead Set
• One pair (red, black) of test leads with
sharp needle point tips adjustable
to desired length from 0 to
76 mm
• Extra hard probe tips
to provide long service life
• Flexible silicone insulated test
leads
• CAT II 150 V, 3 A rating, UL listed

TL932 Patch Cord Set (90 cm)
• 1 pair (red, black) multi-stacking 4 mm
banana plug patch cords
• Nickel-plated banana
plugs
• 90 cm long
PVC insulated leads
• 30 V rms or 60 V DC, 15 A

TL935 Patch Cord Kit
(60, 90, 120 cm)
TL940 Mini-Hook Test Lead Set
• 1 pair (red, black) of test leads with multistacking 4 mm banana plugs and
mini-hooks
• Mini-hooks attach to
component leads up to
1.5 mm diameter
• 90 cm long PVC
insulated leads
• 30 V rms or 60 V DC, 15 A

TL950 Mini-Pincer Test Lead Set
• 1 pair (red, black) of test leads with
multi-stacking 4 mm banana plugs
and mini-pincers
• Mini-pincers open to
2.3 mm
• 90 cm long PVC insulated
leads
• 30 V rms or 60 V DC, 15 A

• 3 sets (red and black pairs) of
multi-stacking 4 mm banana
plug patch cords
• Nickel-plated banana plugs
• 60 cm, 90 cm, 120 cm long PVC
insulated leads
• 30 V rms or 60 V DC, 15 A

Kits
TL80A Basic Electronic Test Lead Kit
• One pair (red, black) each 1 meter long
silicone test lead set,
alligator clip and probe tip
extender.
• C75 soft carrying case
• CAT II 300 V. UL listed

TL81A Deluxe Electronic Test Lead Kit
• Includes components of TL80, plus one pair
(red, black) each
modular 1 meter
long silicone test
lead, test probe,
hook-style and
pinch style clip,
alligator clip, IC
probe tip adapter
and spade lugs
• Quadfold soft
carrying case
• CAT II 300 V. UL listed

TLK287 Electronic Master Test Lead Kit
• Includes modular leads, probes (black and
red), minigrabber/jack
set, medium alligator
clips (black and red),
spade lug/banana jack
plated (set), couplers
IEC1010 (black and red),
micrograbbers and
-leads (black and red)
• TL910 Electronic Test
Lead Set
• Quadfold Pouch
• CAT III 1000 V (probes only)

BP980 Double Banana
Plug Kit
• 5 pair (red, black) of
double
4 mm banana plugs
• Each plug has
3.1 mm holes for
mounting wires and
components
• Brass plugs/jack, beryllium copper springs
• 30 V rms or 60 V DC, 15 A

109

Industrial Test Leads,
Probes & Clips

Test Leads

Modular Test Leads

Kits

TL71 Premium Test Lead Set

TL221 SureGrip™
Extension Lead Set

TL220 SureGrip™
Industrial Test Lead Kit

• One pair (red, black) of silicone
insulated leads with straight
connectors on both ends
• Reinforced strain relief
• Includes one pair (red, black)
of female couplers
• Extends test leads by 1.5 m
• 600 V CAT IV, 1000 V CAT III,
10 A rating. UL listed

• AC220 SureGrip™ Alligator
Clip Set
• TP220 SureGrip™ Test
Probe Set
• TL222 SureGrip™
Silicone Test Lead Set
(right to right)

TL222 SureGrip™
Silicone Test Lead Set

TL223 SureGrip™
Electrical Test Lead Kit

• DMM test leads (red, black)
with safety shrouded, standard
diameter banana plugs
• Right angle connector on
both ends
• Reinforced strain relief
• 1.5 meter silicone-insulated
wire resists heat & cold
• CAT IV 600 V, CAT III 1000 V,
10 A rating. UL listed

• AC220 SureGrip™ Alligator Clip
Set
• TP1 Slim-Reach™ Test
Probes (flat bladed)
• TL224 SureGrip™ Silicone
Test Lead Set
(straight to right)

• One pair (red, black) comfort grip probes
with silicone insulated, right-angle
test leads
• Recommended for μV
measurements
• CAT IV 600 V, CAT III
1000 V, 10 A rating.
UL listed

TL75 Hard Point™ Test Lead Set
• One pair (red, black) comfort grip probes
with PVC insulated, test leads with
right-angle shrouded banana
plugs
• Recommended for
general purpose
measurements
• CAT IV 600 V, CAT III 1000 V,
10 A rating. UL listed

TL76 All-in-one Test Lead Set
• One pair (red, black) 1.5 meter long
silicone test leads with right
angle shrouded banana plug
• Lantern tip (removable)
for use with European
wall sockets (4 mm Ø )
• Lantern tip can be removed
for easy access to terminal
blocks (2 mm Ø)
• Removable, insulated IC caps allow probing
on closely spaced leads and compliance with
GS38.
• Cat IV 600 V, CAT III 1000 V, 10 A rating,
UL listed

TL224 SureGrip™
Silicone Test Lead Set
• DMM test leads (red, black)
with safety shrouded,
standard diameter banana
plugs
• Right angle connector on one end and
straight connector on the other
• Reinforced strain relief
• 1.5 meter silicone-insulated wire resists
heat & cold
• CAT IV 600 V, CAT III 1000 V, 10 A rating.
UL listed

TL27 Heavy Duty
Test Lead Set
• DMM test leads (red, black)
with safety shrouded,
standard diameter banana
plugs
• Heavy duty EPDM insulation
• Length 1.5 m
• CAT III 1000V, 10A rating.
UL listed

H900 Test Lead
Holder

SureGrip™ accessories are designed to
improve steadiness in slippery hands.
Rubber overmolded surfaces and fingerhugging curves give the user a comfortable,
reliable grip on the accessory so they can
focus on making an accurate measurement.
110

• Heavy duty
construction with
mounting holes
• Holder has 10 slots for wires up to
8 mm in diameter
• Over-all dimensions: 27.9 cm
L x 8.9 cm W x 3.2 cm H

TL238 SureGrip™ High Energy
Test Lead Kit
• TP238 SureGrip™ Insulated Tip Test
Probes with less than 4 mm of
exposed metal (GS38) with
flexible removable finger
banner
• TP280 20 cm Test Probe
Extenders
• TL224 SureGrip™ Silicone
Test Lead Set

TLK-220 EUR SureGrip™
Accessory Kit
• AC220 SureGrip™ Alligator
Clip Set
• AC285 SureGrip™ Large Jaw
Alligator Clip Set
• TP74 Slim Reach Test Probe Set
(4 mm)
• TL224 SureGrip™ Silicone Test Lead Set
• Large zippered soft case with moveable
divider

Industrial Test Leads,
Probes & Clips

Kits
TLK-225 SureGrip™
Master Accessory Kit
• AC220 SureGrip™ Alligator
Clip Set
• AC280 SureGrip™ Hook Clip Set
• AC283 SureGrip™ Pincer Clip Set
• AC285 SureGrip™ Large Jaw
Alligator Clip Set
• TP220 SureGrip™ Test Probe Set
• TL224 SureGrip™ Silicone Test
Lead Set
• 6-Pocket Storage Pouch

TLK289 EUR Industrial Master
Test Lead Kit
• C116, Soft Case
• AC220 Alligator Clip Set
• AC280 Hook Clip Set
• AC285 Large Jaw
Alligator Clip Set
• TP74 Lantern Tip
Test Probe Set
• TL224 Test Lead Set
• TPAK Hanging Kit
• 80BK-A Temperature Thermocouple

ACC-T5-KIT Accessory Kit for
use with T5
This kit completes the offering of a T5
with add-on probes and
carrying case.
• TP220 SureGrip™ Test Probe Set
• AC285 SureGrip™ Large Jaw Alligator
Clip Set
• C33 Soft Meter Case

L215 SureGrip™ Kit
with Probe Light and
Extender
• L200 Probe Light
• TP280 20 cm Test Probe
Extenders
• TP220 SureGrip Test Probes
• TL224 SureGrip Silicon Test Lead Set
• Foldable soft pouch with six pockets and
hook-and-loop

Modular Test Probes

Modular Test Probes

(for use with Modular Test Leads)

(for use with Modular Test Leads)

TP220 SureGrip™ Test Probe Set

TP80 Electronic Test Probe Set

• One pair (red, black) of Industrial test probes
• Sharp, 12 mm stainless steel tip
provides reliable contact
• Flexible finger barrier improves
grip
• Recommended for use
with TL222 and TL224
test leads
• CAT IV 600 V; CAT III 1000 V, 10 A rating.
UL listed

Recommended for use with TL222
and TL224
• One pair (red, black)
• IC insulated cap prevents
shortening of IC legs for
probing high density components or boards
• CAT III 1000 V, 10 A rating. UL listed

TLK291 Fused Test Probe Set
• One pair (red, black) fused test probes
• Designed to meet GS38 specs for
United Kingdom
• CAT III 1000V, 0.5A
• Fuse rating:
500 mA/1000 V/FF/50 kA

TP74 Lantern Tip Test Probe Set
• One pair (red, black)
• Tips include banana-style spring
contacts with nickel-plated brass
ends
• CAT III 1000 V, 10 A rating.
UL listed

New

TLK290 Test Probe Kit
• Kit includes three flexible socket probes
and a large alligator clip
• To be used on
three phase sockets.
• Probes have flexible width
test points that fit securely in
4 to 8 mm sockets.
• CAT III 1000 V, 8 A

FTP SureGrip™ Fused Test
Probes
• Built-in fuses for added
protection
• 2 mm threaded probe tips include removable
4 mm lantern-style spring contacts
• Removable GS38 insulted IC caps for probing
closely spaced leads
• CAT III 1000 V, CAT IV 600 V, 10A

New

TP1, TP2, TP4, TP38
SlimReach Test Probe Sets
• One pair (red, black) of slender probes for
closely spaced or recessed terminals
• TP1: Flat blade design to hold
securely in blade type wall
sockets
• TP2: 2 mm diameter
tip for electronics work.
Also compatible with AC72.
• TP4: 4 mm diameter tip
designed to fit into IEC wall
outlets
• TP38: Insulated probe tip
(designed to meet GS38 specs for
United Kingdom).
• CAT IV 600 V, CAT III
1000 V, 10 A rating,
UL listed

FTPL SureGrip™
Fused Test Probes
with Leads
• FTP Fused Test Probes with built-in fuses for
added protection
• Includes TL224 Silicone Insulated Test Leads
• CAT III 600 V, CAT IV 600 V, 10 A

All accessories have a one year warranty

111

Industrial Test Leads,
Probes & Clips
Modular Clips

Modular Clips

Push-on Clip

(for use with Modular Test Leads)

(for use with Modular Test Leads)

(for use with TL71 and TL75 Test Lead Sets)

AC220 SureGrip™ Alligator Clip Set

AC285 SureGrip™
Large Jaw Alligator Clip Set

AC72 Alligator Clip Set

• One pair (red, black) of small, insulated,
nickel plated jaws
• Blunt tip grabs round screw heads up
to 9.5 mm
• Recommended for use with
TL222 and TL224 test leads
• CAT IV 600 V, CAT III
1000 V, 10 A rating.
UL listed

AC280 SureGrip™ Hook Clip Set
• One pair (red, black) of nickel plated clips
• Profile narrows to 5.6 mm at
tip, hook opening 6.4 mm at front,
2 mm at base
• Recommended for use with
TL222 and TL224 test leads
• CAT IV 600 V, CAT III 1000 V,
3 A rating. UL listed

AC283 SureGrip™ Pincer Clip Set
• One pair (red, black) of nickel plated
pincers open to 5 mm
• 11.4 cm flexible insulated shaft
• Recommended for use with
TL222 and TL224 test
leads
• CAT IV 600 V, CAT III
1000 V, 1 A rating.
UL listed

• One pair (red, black) of large alligator
clips with nickel-plated steel jaws
• Multi-purpose tooth pattern grips
anything from fine gauge wire to
a 20 mm bolt
• Recommended for use with
TL222 and TL224 test leads
• CAT IV 600 V; CAT III 1000 V, 10 A rating.
UL listed

AC87 Heavy Duty Bus Bar Clip Set
• One pair (red, black) of
flat, right angle design
for connecting to bus
bars
• Adjustable collar
provides 2 ranges of jaw
openings up to 30 mm
• CAT III 600 V, 5 A rating. UL listed

AC89 Heavy Duty Insulation
Piercing Test Clip
• Single probe pierces
0.25 to 1.5 mm insulated wire
• Small pin allows self-healing of the
insulation
• CAT IV 600V, CAT III 1000 V, 5 A rating.
UL listed

• Slide-on alligator clips (red,
black) for TL71/TL75
• Jaws provide 8 mm opening
• CAT IV 600 V, CAT III 1000 V,
• 10 A rating. UL listed

Test Leads and Probes in one
The new standard for safer electrical
measurements
TL175 and TP175 TwistGuard™ test leads are
the latest in the SureGrip™ technology from
Fluke that provides two safety features in
one set of test leads. These new patented test
leads provide two category rated tips
(CAT III/IV) with a simple twist of the shroud.
The lead wires on the TL175 are equipped with
wear indication, that show when the leads
have excessive wear and that it is time to
replace them. The TL175 and TP175 meet the
new NFPA 70E (IEC 61010-031) safety standard
which is the standard for electrical safety in
the workplace.

New

TL175 TwistGuard™ Test Leads
• Probes meet new IEC 61010 requirements for
safety
• Patented extendable tip sheath meets new
CAT III 1000 V, CAT IV 600 V requirements
while providing the flexibility you need for
CAT II measurements
• Double insulated silicone leads with Wear
indication for increased safety
• Probes always show correct Category rating
for tip being used
• Advanced strain relief exceeds 5,000 bend life
• One-year warranty

112

SureGrip™ accessories are designed to
improve steadiness in slippery hands.
Rubber overmolded surfaces and fingerhugging curves give the user a comfortable,
reliable grip on the accessory so they can
focus on making an accurate measurement.

All accessories have a one year warranty

Automotive Accessories

Piercing Clips

Pressure Module

TP81 and TP82 Insulation Piercing
Clip Set

PV350 Pressure Vacuum Module

• Banana jack accepts all DMM
and banana jack leads
• Available for 4 mm input,
modular connection with
TP81 or available as a 2 mm input to
slip onto probe tips with the TP82
• Tested to 60 V DC

TP84 Oxygen Sensor Insulation
Piercing Clip
• Banana jack accepts
all DMM and banana
jack leads (4 mm)
• Tested to 60 V DC

• Compatible with all Fluke and most popular
DMMs
• Digital pressure and
vacuum measurements in
a single module
• Transducer sealed in 316
stainless steel compatible with
variety of liquids and gases
• Measures vacuum to 76 cm Hg
• Display results in English (psig or Hg) or
metric (kPa or cm Hg) units
• Measures pressure to 500 psig (3447 kPa)

90i-610s AC/DC Current Probe (600 A)

Test Leads

• Flexible silicone insulated
leads are heat and cold
resistant
• CAT I 30 V, 10 A

TP88 Rigid Back Probe Pin Set
• Slides onto test probes measuring
2 mm
• Tested to 60 V DC

TP40 Automotive Back
Probe Pins (five)
• Banana jack accepts all
DMM and banana jack
leads (4 mm)
• Tested to 60 V DC

TLK281 SureGrip™
Automotive
Test Lead Kit
Kit contains:
• TP81 Insulation
Piercing Clip Set
• TL224 SuregripTM
Silicone Test Lead Set
• TP220 SuregripTM Test Probe Set
• AC220 SuregripTM Alligator Clip Set
• AC285 SuregripTM Large Jaw Alligator Clip Set
• Soft Case

BP880
• Allows for hands-free
testing in controlled voltage
environments
500 VRMS maximum
• Banana plug is nickelBP881
plated, beryllium copper for
low contact resistance
• The BNC shell is plated for tarnish resistance
• Operating temperature +50°C maximum

• Current Range: 2 to 600A DC or AC Peak
• Basic Accuracy (DC to 400Hz):
± (2% of reading + 1A)
• Output Signal: 100A range:
10mV/A 600A range: 1mV/A
• Frequency Range: 40Hz to
400Hz
• Working Voltage: 600V
AC rms
• Maximum Conductor
Diameter: 34 mm

Inductive Pick-up
RPM80 Inductive
Pick-up
• Provides RPM readings

ScopeMeter
Accessory Kits
SCC128 Automotive
Accessory Kit
(120 Series)

Banana Plugs
BP880 BNC to Female Double
Stacking Banana Plug
BP881 BNC to Male
Double Stacking
Banana Plug

This set of male and female
adapters allows you to make firm
connection to pin and socket
connectors.
Kit contains:
• Retractable shrouded test lead set
• Complete set of 8 pin-and-socket adapters
with flexible tips
• One red and black in different sizes
• Rated to 60 V DC

Current Probe

TL28A Automotive
Test Lead Set

Probe Pins

TL 82 Automotive
Pin & Socket Adapter
Kit

TLK282 SureGrip™
Deluxe Automotive Test
Lead Kit
Kit contains:
• TP81 Insulation
Piercing Clip Set
• TP40 Automotive
Back Probe Pins
(five)
• TL224 SuregripTM Silicone Test
Lead Set
• TP220 SuregripTM Test Probe Set
• AC220 SuregripTM Alligator Clip Set
• AC285 SuregripTM Large Jaw Alligator
Clip Set
• AC280 SuregripTM Hook Clip Set
• Soft Case

SCC198 Automotive
Accessory Kit
(190 Series)

These kits provide a host of accessories
that allow you to easily and quickly make
measurements on automotive electronic
systems using a 120 or 190 Series ScopeMeter.

113

Current Clamps

i5s

i50s

i200

i200s

i400

i400s

Specifications AC models
i5s

i50s

i200

i200s

i400

i400s

Nominal current range(s

5A

3/30 AC RMS or DC

200 A

20 A
200 A

400 A

40 A
400 A

Continuous AC current range

0.01 A - 6 A

30 A cont. 50 A<10 sec

0.5 A - 200 A

0.1 - 24 A
0.5 A - 200 A

5 A - 400 A

0.5 - 40 A
5 A - 400 A

Highest current
Lowest measurable current
Basic accuracy (48-65 Hz) 1)

70 A
10 mA
1%

240 A
0.5 A
1% + 0.5 A

240 A
0.5 A
1.5% + 0.5 A

1000 A
1A
2% + 0.15

1000 A
0.5 A
2% + 0.15

Useable frequency
Max. working voltage
Maximum conductor diameter

40 Hz - 5kHz
600 V AC
15 mm

30 A cont. 50 A<10 sec
10 mA
± 5% typical DC
to 100 kHz
DC to 50 MHz
300 V AC RMS or DC
5 mm

40 Hz - 10 kHz
600 V AC
20 mm

40 Hz - 10 kHz
600 V AC
20 mm

45 Hz - 3 kHz
1000 V
32 mm

45 Hz - 3 kHz
1000 V
32 mm

Output level(s)

400 mV/A

1/100 mV/A

1 mA/A

100 mV/A
10 mV/A

1 mA /A

10 mV/A
1 mV/A

2.5

External Power
2

1.5
O

2.0

1.5
O

2.5

•

O

CAT III, 600 V

CAT I 300 V

Batttery, battery life
Output cable (m)
Shrouded banana plugs
BNC connector
BNC to banana adapter included
Safety
1)

i1000s

i2000 flex

i3000s flex

i800

i10000s

i2000 flex

Nominal current range(s)

800 A RMS

Continuous AC current range

0.1 A - 800 A RMS

Highest current
Lowest measurable current
Basic accuracy (48-65 Hz) 1)
Useable frequency
Max. working voltage
Maximum conductor diameter

1500 A
0.1 A
0.10%
30 Hz - 10 kHz
600 V AC RMS or DC
54 mm

10 A
100 A
1000 A
0.1 A - 10 A
0.1 A - 100 A
1 A - 1000 A
2000 A
0.1 A
1% + 1 A
5 Hz - 100 kHz
600 V AC
54 mm

20 A
200 A
2000 A
1 A - 20 A
2 A - 200 A AC RMS
30 A - 2000 A
2500 A AC RMS
1A
1%
10 Hz - 20 kHz (-3dB)
600 V AC RMS
178 mm

Output level(s)

1 mA/A

100 mV/A
10 mV/A
1 mV/A

100 mV/A
10 mV/A
1 mV/A
200 hours
0.5
O
n/a
n/a
CAT III, 600 V

Batttery, battery life
Output cable (m)
Shrouded banana plugs
BNC connector
BNC to banana adapter included
Safety

114

O
O
CAT III, 600 V

O
CAT III 1000 V /
CAT IV 600 V

CAT III 1000 V /
CAT IV 600 V

Basic Accuracy: % reading + floorspec

i800

1)

CAT III. 600 V

Basic Accuracy: % reading + floorspec

1.6
O

1.6
O

CAT III, 600 V

CAT III, 600 V

i3000s flex-24
i3000s flex-36
30 A
300 A
3000 A
1 A - 30 A
2 A - 300 A AC RMS
30 A - 3000 A
3500 A AC RMS
1A
1%
10 Hz - 50 kHz (-3dB)
600 V AC RMS
Flex-24 178 mm
Flex-36 275 mm
100 mV/A
10 mV/A
1 mV/A
400 hours
0.5
n/a
O
O
CAT III, 600 V

i3000s

i6000s flex

i3000s

i60000 flex-24
i6000s flex-36
60 A
600 A
6000 A AC
1 A - 6000 A AC RMS

30 A
300 A
3000 A
1 A - 30 A
1 A - 300 A
1 A - 2400 A
4000 A
1A
2% + 2 A
10 Hz - 100 kHz
600 V AC
64 mm

2.1

6000 A
1A
± 1% of range
10 Hz to 50 kHz
600 V AC RMS or DC
Flex-24 170 mm
Flex-36 275 mm
50 mV/A
5 mV/A
0.5 mV/A
400 hours
0.5

O
O
CAT III, 600 V

O
O
CAT III, 600 V

10 mV/A
1 mV/A
0.1 mV/A

Current Clamps

80i-110s

i30

i30s

i310s

i410

i1010

Specifications AC/DC Models

Highest current

80i-110s
Hall sensor
10 A, AC/DC
100 A, AC/DC
0.1 A - 10 A AC/DC
1 A - 100 A AC/DC
140 A - 2 kHz

Lowest measurable current
Basic accuracy 1)
Useable frequency
Zero error adjustment

0.1 A
3% + 50 mA (@ 10 A)
DC - 100 kHz
O

Max. working voltage
Maximum conductor diameter

600 V
11.8 mm

Output level(s)

100 mV/A
10 mV/A
9 V, 55 h
1.6

Measurement type
Nominal current range(s),
Continuous current range

Battery, battery life
Output cable length (m)
Shrouded banana Plugs
BNC connector
BNC to banana adapter included
Safety

1)

O
CAT II, 600 V
CAT III, 300 V

i30
Hall sensor
20 A AC RMS or DC

i30s
Hall sensor
20 A AC RMS or DC

i310s
AC/DC
30/300 A AC RMS
or 45/450 A DC
100 mA - 300 A AC
RMS or 450 A DC
300 A AC RMS or
450 A DC
100 mA
±1% of reading
DC to 20 kHz
Manual

30 A AC Peak

30 A AC Peak

30 A AC Peak

30 A AC Peak

50 mA
± 1% of reading ±2 mA
DC to 20 kHz (-0.5dB)
manual adjust via
thumbwheel
300 V AC RMS
19 mm

50 mA
± 1% of reading ±2 mA
DC to 100 kHz (-0.5dB)
manual adjust via
thumbwheel
300 V AC RMS
19 mm

100 mV/A

100 mV/A

10/1 mV/A

30 hours typical
1.5
O
n/a
n/a
CAT III, 300 V

30 hours typical
2
n/a
O
O
CAT III, 300 V

30 hours
2

i410
Hall sensor
400 A, AC/DC

400 A

i1010
Hall sensor
600 A, AC
1000 A, DC
1 A - 600 A, AC
1 A - 1000 A, DC
1000 A

0.5 A
3.5% + 0.5 A
DC - 3 kHz
O

0.5 A
2% +0.5 A
DC - 10 kHz
O

600 V
30 mm
2 x 25 mm
1 mV/A

600 V
30 mm
2 x 25 mm
1 mV/A

9 V, 60 h
1.6
O

9 V, 60 h
1.6
O

CAT III, 600 V

CAT III, 600 V

1 A - 400 A AC/DC

300 V AC RMS or DC
19 mm

O
O
CAT III 300 V

Basic Accuracy: % reading + floorspec

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

2

2

2

2

2

2

2

2

2

2

2

O

O
O
O
O
2

O

O

O

O

O

O

O
O

O

O

O

O
3
O
O

O
3
O
O

O
3
O
O

O
O
O
3
3

O
O
O
3
3

O
O
O
3
3

O
O
O
O

O

O

O

2

O
3
O
O

3
O
O
O

789

4
2
O
O
O
O

O

787

O
O
O
2

741B/743B/744

O
O
O
2

725

O
O
O
2

724

88V

O
O
O
2

715

83V/87V

O
O
O
2

1577/1587

77 IV

O
O
O
2

190 Series/215C/225C

8808A

O
O
O
2

4
O

125

8845A/8846

O
O
O
2

123/124

27II / 28II

O
O
O
2

430 Series

287/289

2

O
O
O
2

43B

233

• Combination of current clamp with
carrying case
• Zipped soft case with moveable
divider
• Soft case is large enough to hold a
meter

187/189

i410 Kit AC/DC Current Clamp
(400A) with soft case
i1010 Kit AC/DC Current Clamp
(1000A) with soft case

AC Models
i5s
i200
i200s
i400
i400s
i430 flex
i800
i1000s
i2000 flex (new version)
i3000s
i3000s flex
i6000s flex
AC/DC Models
i30
i30s
80i-110s
i310s
i410 / i410 kit
i1010 / i1010 kit
Other
90i-610s*

175/177/179

113/114/115/116/117

Current Clamp Compatibility Chart

O
O
O
2

O
O
O
2

O
2
O
O
O
O

O
2
O
O
O
O

O

O

2
O
O
O

2
O
O
O

2
O
O
O

2

2

2

O
2

O
2
O
O
O
O

2
O
O
O

O
O
O
O

O
O
O

1
1

1
1

1
1

* For specifications of 90i-610s see page 113
1 For DC only
2 Requires PM 9081 (see page 76)
3 Requires PM 9082 (see page 76)
4 115, 117 only

All accessories have a one year warranty

115

Temperature Accessories

DMM Probes

Contact Probes
80PK-22 SureGrip™ Immersion Probe

80PK-1 and 80PJ-1 Bead Probe

80AK-A Thermocouple Adapter

• Type-K thermocouple for use in liquids
and gels
• Measurement range:
-40 to 1090°C
• Probe length: 21.3 cm

• 80PK-1: Type-K thermocouple for
general purpose applications
• 80PJ-1 operates with J-type
thermometers
• Measurement range:
-40 to 260°C
• Probe length:
1 m lead wire

• Adapts Type-K thermocouple
mini-connector to dual banana
plug inputs
• Measurement range and
accuracy: probe dependent
• Suitable for low voltage applications
(below 30 V AC, 60 V DC)

80BK-A Integrated DMM
Probe

80PK-24 SureGrip™ Air Probe
• Type-K thermocouple for use in
air and non-caustic gas measurements
• Bead protected by
perforated baffle
• Measurement range:
-40 to 816ºC
• Probe length: 21.6 cm

80PK-3A Surface Probe
• Type-K thermocouple for flat or
curved surfaces such as
plates and rollers
• Measurement range:
0 to 260°C
• Probe length:
9.5 cm

80PK-25 and 80PT-25 SureGrip™
Piercing Probe
• 80PK-25: Type-K thermocouple suitable for
food industry, liquids and gels
• 80PT-25 operates with T-type
thermometers
• Measurement range:
80PK-25: -40 to 350°C
80PT-25: -196 to 350°C
• Probe length: 10.2 cm

116

80PK-8 / 80PK-10 Pipe Clamp
Temperature Probe

New
• Type-K thermocouple for
fast temperature and
superheat measurements
of pipe surfaces
• Durable ribbon sensor
• Measurement range:
-29 to 149°C for pipe diameters
from 6.4 to 34.9mm (80PK-8) and
32 mm to 64 mm (80PK-10)

80PK-26 SureGrip™ General Purpose
Probe

80PK-9 and 80PJ-9 General
Purpose Probe

• Type-K thermocouple with tapered tip
for use in air, non-caustic gas and
surface applications
• Measurement range:
-40 to 816ºC
• Probe length: 21.2 cm

• 80PK-9: Type-K thermocouple surface,
air and non-caustic gases
• 80PJ-9 operates with
J-type thermometers
• Measurement range:
-40°C to 260°C
• Probe length:
15.3 cm

80PK-27 SureGrip™ Industrial Surface
Probe

80PK-11 Velcro
Temperature Probe

• Type-K thermocouple for surfaces
in rugged environment
• Durable ribbon sensor
• Measurement range: -127
to 600°C
• Probe length: 20.3 cm

• Type-K thermocouple
for hands free
measurement of
HVAC temperature
measuring
applications
• Total length of cable:
1m (0.5m in cable, 0.5m in
Velcro cuff insulation material; Hytrel)
• Measurement range: -30ºC to 105ºC

• Type-K thermocouple with
standard banana jack
• Convenient one piece construction
• Compatible with DMMs
with temperature
measurement functions
• Measurement range:
-40 to 260ºC

80TK Thermocouple Module
• Converts a DMM to
a thermometer
• For use with type-K
thermocouples in low voltage
applications (below
24 V AC, 60 V DC)
• Measurement range:
-50 to 1000°C (probe dependent)

80T-150UA Universal Temperature Probe
• Compatible with
Fluke DMM
• High accuracy, fast
reading for low voltage
(below 24 V AC, 60 V DC)
applications
• Measurement range:
-50 to 150°C
• Output: 1 mV/°C or 1 mV/°F (switchable)

SureGrip™ accessories are designed to
improve steadiness in s lippery hands.
Rubber overmolded surfaces and fingerhugging curves give the user a comfortable,
reliable grip on the accessory so they can
focus on making an accurate measurement.

Temperature Accessories

Other Temperature Accessories
80PR-60 RTD Temperature Probe
• For simulaneously taking contact and
non-contact temperature
measurements with
Fluke 66 or 68
• Measurement range:
-40 to 260°C

New

80CK-M & 80CJ-M type K & J Male
Mini-Connectors

Thermocouple Plug Kits
700TC1

• Isothermal screw
terminal for K or J
wire
• Suitable for up to
20 guage
thermocouple wire
• Color coded to
industry standards
(K-yellow, J-black)
• Two per package

A kit of 10 mini-plug
connectors
Type J (black), one
Type K (yellow), one
Type T (blue), one
Type E (purple), one
Type R/S (green), one
Type B or CU (white), one
Type L (J-DIN) (blue), one
Type U (T-DIN) (brown), one
Type C (red), one
Type N (orange), one

80PK-EXT, 80PJ-EXT and
80PT-EXT Extension Wire Kits

700TC2

• Extending and repairing J, K ot T-type
thermocouple wires
• Kit includes 3 meters of thermocouple wire
and 1 pair of male/female mini-connectors
• Maximum continuous exposure temperature:
260ºC
• 80PK-EXT is compatible
with K-type thermometers,
80PJ-EXT is designed for
J-type thermometers and
PT-EXT for T-type
thermometers

80PK-18 Pipe
Clamp Temperature Probe Kit
• 80PK-8 Pipe Clamp Temperature Probe
• 80PK-10 Pipe Clamp Temperature Probe
• Soft Case

A kit of 7 mini-plug connectors
Type J (black), two
Type K (yellow), two
Type E (purple), one
Type T (blue), one
Type R/S (green), one

190 Series/225C/215C

1577

1587

1

1

1

1

2

1
O
O

O
O

O
O

O
O

O
O

O

O

O

O

O
O

O
O

O
O

1

1

2

2

2

2

1

1

1

2

1

1

2

2

2

2

1

1

1

2

O3)
O3)

O
O

O
O

O
O
O

O

O

1

O
O
O

1

O
O
O

O
O
O

O
O
O

789

120 Series

2

787

43B

2

741B/743B/744

88V

1

725

87V

1

724

83V

1

715

77IV

2

714

8845A/8846A/8808A

2

705/707

27II / 28II

2

66/68

287/289

2

566/568

233

1

561

179

1

51/52/53/54 II

175/177

Contact Probes
80PK-1 … 80PK-27
80PJ-1, 80PJ-9
80PT-25
DMM probes
80AK-A
80BK-A
80TK
80T-150UA
Miscellaneous
80CK-M
80CJ-M
80PK-EXT4)
80PJ-EXT
80PT-EXT
700TC1, 700TC2
80PR-60

113/114/115/116/117

Temperature Probe Compatibility Chart

1

1

O
O

O
O

O
O

O
O
O
O
O
O

1

1

1

1

O
O
O
O

O
O

O
O

O
O

O
O

2

1

1

1

1

2

2

1

1

1

1

2

O
O
O
O
O
O

O

O

1

O

O

1

O
O
O
O
O
O
O
O

1
1

O
O
O
O
O
O

O
O
O
O
O
O

O

1) Requires 80TK
2) Requires 80AK
3) Fluke 116 only
4) Also requires 80CK-M

All accessories have a one year warranty

117

Cases and Holsters
Soft Cases
Zipped carrying cases protect your meter; most cases come with belt loops so your meter is
stored conveniently on your tool belt.

C195
• Zipped carrying
case with storage
compartments
• Allows hand or
shoulder use

C789

C12A

C23

C25

• Large fabric carrying case
with 3 compartments,
removable handle and
shoulder strap

C35

C33

C550 Tool Bag

C570

C43

C50

C75

C90

C115

C116

C125/C781

C280

C345

• Steel reinforced frame
• Rugged ballistic
cloth with heavy duty
hardware
• Large zippered storage
compartment with
25 pockets
• Weather resistant
• Carry all your tools to
the job

118

787

789

741B/743B/744

724/725/726

718

712/714/715/717

705/707

63/66/68

61

O

570 Series

51/52/53/54 II

O
O

566/568

971

O
O

561

922

190 Series/225C/215C

43B/120 Series

O

430 Series

9040/9062

O

1735/1740 Series

1503/1507/1577/1587

353/355

333/334/335/336/337/902

321/322

T100 Series

T50

T5

O

O
O
O
O

83V/87V/88V

77 IV

O

27II / 28II

O

287/289

O
O
O

233

175/177/179

Soft Cases
Size (HxWxD) mm
C12A
172 x 128 x 38
C23
225 x 95 x 58
C25
218 x 128 x 64
C33
280 x 115 x 55
C35
220 x 140 x 65
C43
318 x 230 x 90
C50
192 x 90 x 38
C75
179 x 103 x 26
C90
205 x 90 x 72
C115
240 x 205 x 75
C116
240 x 230 x 65
C125
192 x 141 x 58
C195
231 x 513 x 231
C280
230 x 185 x 65
C345
240 x 360 x 200
C550
333 x 513 x 231
C570
240 x 160 x 61
C781
269 x 141 x 90
C789
308 x 256 x 77
Hard cases
C20
256 x 154 x 106
C100
397 x 346 x 122
C101
305 x 360 x 105
C120
346 x 397 x 128
C190
410 x 474 x 135
C435
565 x 476 x 305
C800
230 x 385 x 115
C1600
260 x 390 x 200
CXT80
28 x 32 x 13
CXT170
28 x 32 x 13
CXT280
28 x 32 x 13
Leather Cases
C510
287 x 179 x 106
C520A
256 x 154 x 106
Holsters
C10
154 x 77 x 45
H80M
190 x 95 x 43
Other
H3
231 x 90 x 64
H5
192 x 90 x 38
H6
302 x 178 x 57
Hanging Kit (see page 120)
ToolPak

113/114/115/116/117

Cases & Holsters Compatibility Chart

O
O

O

O

O

O

O

O

O
O

O
O

O

O

O

O

O

O
O
For multiple test leads and accessories
O
O
O O
O O
O O O O O O O
O

O

O

O

O

O
O

O

O
O
O
O
O
O

O O O O O O O
For multiple test leads and accessories
For multiple test leads and accessories

O

O
O
O
O
O

O
O

O
O

O
O

O

O
O

O

O

O
O
O

O

O

O

O

O
O

O

O

O
O

O

O

O
O

O

O
O

O

O

O
O

O
O

O

O
O

O

O

O
O

O
O

O

O

O

O

O

O
O

O

O

O

O

O

O
O

O
O

O
O
O
O O
O O O
For multiple test leads and accessories
O
O
O
O

O

O
O

O
O

O

O

O

O

O

O

O

O

O

O
O

O

O

O

O
O
O

O
O

O

O

O

O
O
O

O

O

O

O

O

O

O

O

O

O
O

O

O

Cases and Holsters
Hard Cases

Holsters

C20 Meter Case

C10 Meter Holster

H3 Clamp Meter Holster

• Heavy duty case with
carrying handle and
accessories storage
compartment
• Top cover snaps onto back to
serve as tilt stand

• Snap-on yellow holster
absorbs shocks and protects
meter from rough handling
• Includes built-in stand and
hanger loop

• Fabric holster absorbs
shocks and protects
meter from rough
handling.
• Built-in pocket for lead
storage
• Convenient belt-loop with snap

H80M Holster + Magnetic Hanger
C100 Meter and
Accessory Case
• Tough polyprophylene case

C101 Hard Case
The hard case that fits all Fluke
industrial test tools. Configure
the diced foam interior to store
and protect what you need to
carry with you.
• Tough polyprophylene exterior shell
• Interior cavity measures

• Snap-on yellow
holster absorbs shocks
and protects meter from
rough handling
• Magnet, hook and loop
straps
• General purpose hanger

H5 Electrical Tester Holster
• Rugged fabric holster includes flap for lead
storage and built-in belt
loop
• Fits Fluke T3 and T5
testers

H6 Infrared Thermometer Holster
• Durable nylon holster
• For Fluke 63, 66 and 68 Infrared
Thermometers

C120 and C190 Cases
• Heavy duty cases with accessory
storage compartments

C435 Hard Rolling Case
• Watertight hard case
with rollers for 430 Series,
1735 and 1740 Series
Power Quality products and
accessories. The
configurable foam securely
holds any of these
instruments during transit.

C800 Meter and Accessory Case

Leather Cases
C510 Leather Meter Case

C520A Leather Tester Case

• Oiled genuine top grain cowhide
• Rugged construction with heavy duty
stitching and reinforced rivets
• Large tool belt loop and
top flap to secure meter
• Holds most Fluke DMMs,
Thermometers, and
Process Calibrators

• Oiled genuine top grain cowhide
• Oil tanned for long life
• Rugged construction with heavy duty
stitching and reinforced rivets
• Large tool belt loop and
top flap to secure tester
• Holds Fluke Electrical
Testers

• Tough polyprophylene case
• Accessories and manual
compartments
• Detachable lid

C1600 Meter and Accessories Case
• Rugged molded plastic case
• Deep interior large enough to hold
and protect your tools
• Lift out tray keeps
everything organized
• Snap open compartment
on top of lid

CXT80, CXT170, CXT280 Rugged Pelican
Hard Case
• Unbreakable, watertight,
airtight, dustproof, chemical
resistant and corrosion proof
case

All accessories have a one year warranty

119

Software and other Accessories

Software FlukeView® Forms

Hanging Kit

FlukeView Forms increases the power of your
Fluke tool by enabling you to document, store
and analyze individual readings or series
of measurements, then convert them into
professional-looking documents. FlukeView
Forms supports the following multimeters:

ToolPak (TPAK)
The meter hanging solution
• Kit includes, universal hanger clips (2), hook
& loop straps (2 lengths) and strong magnet
• Combine components to meet most hanging
needs
See page 118 for compatibility chart

FlukeView Forms Compatibility Chart
FVF Option
FVF-UG
FVF-SC1
FVF-SC2
FVF-SC4
FVF-BASIC
FVF-SC5

Instrument
Software only upgrade, Any instrument that
supports Flukeview Forms Software
Fluke 53-II, 54-II, 87-IV*, 89-IV*
Fluke 280 Series, 789, 1550B, 1653B, 568,180 Series*
Fluke 8808A, 8845A, 8846A, 45*, 975
Fluke 280 Series, 789, 1550B, 1653B, 180 Series*
8808A, 8845A, 8846A, 45*

Cable**

Application Level

No Cable included
Serial / IRDA
USB / IR
USB / Serial
USB / IR
USB / Serial

FVF Full (includes Designer)

FVF BASIC

* Obsolete
** USB cables are not supported for Microsoft Windows NT 4.0

IR189USB
IR to USB interface cable
(included with FVF-SC2 and FVF-Basic)
• For customers who want to upgrade from
their existing RS232 cable
• Small adapter to connect the cable to the 189,
287, 289, 1653B or the 1550B is included.
• CD-Rom with drivers for use with older
versions of FVF-SC1 included.

Fiber Optics
FOM Fiber Optic Meter

Make extended logging easier
BP189 High Capacity Battery Enclosure
(for Fluke 180 Series DMM)
• Expand the battery life of your Fluke
187/189 up to 450 hours (over two weeks of
continuous use).
• Houses 4 ‘C’ cell batteries.
• CAT III 1000 V, CAT IV 600 V
Batteries and meter sold separately

120

The Fluke Fiber Optic Meter (FOM) helps you
test and maintain fiber optic cables without
having to buy a whole new
meter. Plug the FOM
directly into any DMM with
a mV dc function and a
10 MΩ input impedance and
quickly and accurately
verify fiber optic cable system loss. Light
sources and patch cords sold separately.

FOS 850 & FOS 850/1300
Fiber Optic Light Sources
A variety of light sources allow you to test
different cable lengths.

All accessories have a one year warranty

Other Accessories

Lights

Stray Voltage Adapter

High Voltage Probes

L200 Probe Light

SV225 Stray Voltage Adapter

80K-6 and 80K-40

• Attaches to any Fluke test probe
• Bright white LED
• 120 hours of battery life

Stray voltage can appear in
electrical installations, due to
the capacity between wires.
This may result in erroneous
readings on high impedance
meters.

A high voltage probe that
allows a multimeter to
measure up to 6,000V or
40,000V respectively.
Intended for low energy applications only

L205 Mini Hat Light
Rugged high-intensity
Xenon worklight
• Attaches to a baseball cap
• Includes a hat clip
• Includes two AAA
batteries
• Waterproof

L206 Deluxe LED Hat Light
(hard hat not included)
Attach it to a hard hat,
a baseball cap, or even a
panel door for all the light
you need.
• 3 super bright white LEDs
– never burn out
• Special hard-hat attachment included
• 40-hour battery life
• Includes three AAA batteries

The SV225 solves this without
compromising safety.
• On energized wires, the meter will indicate
the real voltage.
• On non-energized circuits the meter
will read close to zero (even if there
are stray voltages).
• It can be used with all modern
meters with standard input spacing.
• Rated CAT III 1000 V, CAT IV 600 V

TL225 SureGrip™ Stray Voltage Adapter
Test Lead Kit
Kit includes:
• SV225 Stray Voltage
Eliminator
• TL224 SureGrip™
Silicone Test Lead Set
(right to straight)
• TP220 SureGrip™ Test
Probe Set
• C75 Accessory Case

L210 Probe Light +
Probe Extender
• Includes L200 Probe Light
and TP280 Test Probe
Extenders
• 20 cm probe extenders
keep hands away from
live circuits
• Extender fits between modular test probe
and test lead (total reach 30 cm)

Meter Cleaners
MC6 MeterCleaner™ Wipes (6-pack)
MC50 MeterCleaner™ Wipes
(50-pack)
• Pre-moistened wipe removes dirt, oil and
grease
• One wipe easily cleans one meter
• Safe on rubber, plastic and for environment
(non-toxic)

All accessories have a one year warranty

121

Product Quick Find List
Model

122

Page

Fluke 1AC I
32
Fluke 1AC II
32
Fluke 1AC II 5PK
32
Fluke 27II
21
Fluke 28II
21
Fluke 43B
81
Fluke 51 II
55
Fluke 52 II
55
Fluke 53 II
55
Fluke 54 II
55
Fluke 61
52
Fluke 62/322/1AC Kit 5, 52
Fluke 62
52
Fluke 63
52
Fluke 66
52
Fluke 68
52
Fluke 771V
20
Fluke 83V
17
Fluke 87V
17
Fluke 87V Ex
107
Fluke 87V/E2 Kit
4
Fluke 87V/i410
4
Fluke 88V/A
22
Fluke 113
19
Fluke 114
19
Fluke 115
19
Fluke 116
19
Fluke 117
19
Fluke 117/322 Kit
4
Fluke 123
73
Fluke 123/S
73
Fluke 124
73
Fluke 124/S
73
Fluke 125
73
Fluke 125/S
73
Fluke 175
18
Fluke 177
18
Fluke 179
18
Fluke 179/TPAK kit
4
Fluke 179/EDA2 Kit
4
Fluke 179/MAG2 Kit
4
Fluke 179/61 Kit
4
Fluke 192C
75
Fluke 192C/S
75
Fluke 196C
75
Fluke 196C/S
75
Fluke 199C
75
Fluke 199C/S
75
Fluke 215C
75
Fluke 215C/S
75
Fluke 225C
75
Fluke 225C/S
75
Fluke 233
16
Fluke 287
15
Fluke 289
15
Fluke 287/FVF
5
Fluke 289/FVF
5
Fluke 321
27
Fluke 322
27
Fluke 333
26
Fluke 334
26
Fluke 335
26
Fluke 336
26
Fluke 337
26
Fluke 345
80
Fluke 353
28
Fluke 355
28
Fluke 360
29
Fluke 411D/62 Kit
5, 65
Fluke 411D
65
Fluke 416D
65
Fluke 421D
65
Fluke 434
83
Fluke 434 Basic
83
Fluke 434 LOG
83
Fluke 435
83
Fluke 435 Basic
83
Fluke 561
54
Fluke 566
53
Fluke 568
53
Fluke 572
51
Fluke 572CF
51
Fluke 574
51
Fluke 574CF
51
Fluke 700 Ex
107
Fluke 705
99
Fluke 707
99

Model

Page

Fluke 707 Ex
99,107
Fluke 712
96
Fluke 714
96
Fluke 715
99
Fluke 717 1G
98
Fluke 717 100G
98
Fluke 717 1000G
98
Fluke 717 1500G
98
Fluke 717 30G
98
Fluke 717 300G
98
Fluke 717 500G
98
Fluke 717 3000G
98
Fluke 717 5000G
98
Fluke 718 Ex
98,107
Fluke 718 1G
98
Fluke 718 30G
98
Fluke 718 100G
98
Fluke 718 300G
98
Fluke 719 30G
98
Fluke 719 100G
98
Fluke 724
95
Fluke 725
94
Fluke 725 Ex
94,107
Fluke 726
94
Fluke 741B
93
Fluke 743B
93
Fluke 744
93
Fluke 771
100
Fluke 772
100
Fluke 773
100
Fluke 787
101
Fluke 789
101
Fluke 810
104
Fluke 902
26
Fluke 922
68
Fluke 922/Kit
68
Fluke 971
69
Fluke 975
67
Fluke 975V
65
Fluke 983
70
Fluke 1503
38
Fluke 1507
38
Fluke 1523
56
Fluke 1523-P1
56
Fluke 1524
56
Fluke 1524-P1
56
Fluke 1550B
39
Fluke 1577
37
Fluke 1587
37
Fluke 1587/ET
5, 36
Fluke 1587/MDT
5, 36
Fluke 1587T
37
Fluke 1621
41
Fluke 1623
40
Fluke 1623 Kit
40
Fluke 1625
40
Fluke 1625 Kit
40
Fluke 1630
42
Fluke 1651B
44
Fluke 1652B
44
Fluke 1653B
44
Fluke 1735
84
Fluke 1743
85
Fluke 1743 Basic
85
Fluke 1744
85
Fluke 1744 Basic
85
Fluke 1745
85
Fluke 1750
86
Fluke 1750/B
86
Fluke 1760
87
Fluke 1760 Basic
87
Fluke 1760TR
87
Fluke 1760TR Basic
87
Fluke 2042
34
Fluke 2042T
34
Fluke 4180
97
Fluke 4181
97
Fluke 4180-CASE
97
Fluke 4180-DCAS
97
Fluke 6200
46
Fluke 6500
46
Fluke 8808A
24
Fluke 8808A/SU
24
Fluke 8808A/TL
24
Fluke 8845A
23
Fluke 8845A/SU
23
Fluke 8846A
23

Model

Page

Fluke 8846A/SU
23
Fluke 9040
33
Fluke 9062
33
Fluke 9142-X
97
Fluke 9143-X
97
Fluke 9144-X
97
Fluke CO-205
69
Fluke CO-220
69
Fluke Norma 4000
89
Fluke Norma 5000
89
Fluke RLD2
70
Fluke T5-600
31
Fluke T5-600/62/1AC Kit
5, 31
Fluke T5-H5-1AC Kit 5, 31
Fluke T5-1000
31
Fluke T50
30
Fluke T100
30
Fluke T120
30
Fluke T140
30
Fluke Ti9
60
Fluke Ti10
60
Fluke Ti25
61
Fluke Ti32
61
Fluke TiRx
62
Fluke TiR
62
Fluke TiR1
63
Fluke TiR32
63
Fluke VR1710
79
80AK-A
116
80BK-A
116
80CJ-M
117
80CK-M
117
80i-110s
115
80K-40
121
80K-6
121
80PJ-1
116
80PJ-9
116
80PJ-EXT
117
80PK-1
116
80PK-3A
116
80PK-8
116
80PK-9
116
80PK-10
116
80PK-11
116
80PK-18
117
80PK-22
116
80PK-24
116
80PK-25
116
80PK-26
116
80PK-27
116
80PK-EXT
117
80PR-60
117
80PT-EXT
117
80T-150UA
116
80TK
116
90i -610s
113
700HTH
102
700HTP
102
700ILF
102
700LTP
102
700P00
102
700P01
102
700P01 Ex
102,107
700P02
102
700P03
102
700P04
102
700P05
102
700P05 Ex
102,107
700P06
102
700P06 Ex
102
700P07
102
700P08
102
700P09
102
700P09 Ex
102,107
700P22
102
700P23
102
700P24
102
700P24 Ex
102,107
700P27
102
700P27 Ex
102,107
700P29
102
700P29 Ex
102,107
700P30
102
700P31
102
700PA3
102
700PA4
102

Model

Page

700PA4 Ex
102,107
700PA5
102
700PA6
102
700PCK
102
700PD2
102
700PD3
102
700PD4
102
700PD5
102
700PD6
102
700PD7
102
700PRV
102
700PTP
102
700PV3
102
700PV4
102
700SW
93
700TC1
117
700TC2
117
884X-case
18
884X-512M
18
975CK
67
975R
67
975VP
67
2373-LPRT
56
2384P
56
2384T
56
5616-12-P
56
5615-9-P
56
5610-9-P
56
AC72
112
AC87
112
AC89
112
AC220
112
AC280
112
AC283
112
AC285
112
ACC-T5-Kit
111
AN5
51
APP1000/APP2000
48
AS200-G
76
AS200-R
76
BDST3
48
BDST4
48
BE9005
94
BP120MH
76
BP189
120
BP190
76
BP880
113
BP881
113
BP980
109
BP7235
102
C10
118
C12A
118
C20
119
C23
118
C25
118
C280
118
C33
118
C345
118
C35
118
C43
118
C50
118
C75
118
C90
118
C100
119
C101
119
C115
118
C116
118
C120
119
C125
118
C190
119
C195
118
C435
119
C510
119
C520A
119
C550
118
C570
118
C781
118
C789
118
C800
119
C1600
119
CXT80
119
CXT170
119
CXT280
119
DMS 0100/INST
48
DMS 0702/PAT
48
DMS COMPL PROF
48
DP120
76

Model

Page

EI-1623
40
EI-1625
40
EI-162BN
40
ES-162P3
40
ES-162P4
40
ES165X (1653)
48
EXTL100
48
FLK-075-CLKT
59
FLK-100-CLKT
59
FLK80P1
56
FLK80P3
56
FLK-LENS-TELE1
61-63
FLK-LENS-WIDE
61-63
FLK-Ti-SPB3
61-63
FOM
120
FOS 850
120
FOS 1300
120
FS17XX
88
FTP SureGrip fused test
probes
111
FTPL SureGrip fused test
probes with leads
111
FVF- Basic
120
FVF-SC1
120
FVF-SC2
120
FVF-SC4
120
FVF-SC5
120
FVF-UG
120
GPS430
83
H3
119
H5
119
H6
119
H80M
119
H900
110
i1A/10A Clamp PQ3
88
i1A/10A Clamp PQ4
88
i5A/50A Clamp PQ3
88
i5A/50A Clamp PQ4
88
i5s
114
i20/200A Clamp PQ3
88
i20/200A Clamp PQ4
88
i30
115
i30s
115
i50s
114
i200
114
i200s
114
i310s
115
i400
114
i400s
114
i410
115
i410 Kit
115
i430-flex-4pk
88
i5sPQ3
88
i800
114
i1000s
114
i1010
115
i1010 Kit
115
i2000flex
114
i3000flex
114
i3000s
114
i6000s flex
114
IP-200-UK
59
IR 189USB
120
L200
121
L205
121
L206
121
L210
121
L215
111
LVD1
32
LVD2
32
MC6
121
MC50
121
MTC1363 (UK)
48
MTC77 (Europa)
48
OC4USB
76
PAC91
76
PASS560R
48
PM8918/301
76
PM9080
76
PM9081
76
PM9082
76
PM9090
76
PM9091
76
PM9092
76
PM9093
76
PM9094
76
PT12
68

Model

Page

PV350
113
RPM80
113
RS200
76
SCC120
73
SCC128
113
SCC190
75
SCC191
75
SCC198
113
SM100
32
SM200
32
SM300
32
SP1000
48
SP-Scan-15
48
SV225
121
SW90W
75
Ti-Car Charger
60-63
Ti-SBC3
61-63
Ti-TRIPOD
60-63
Ti-Visor
60-63
TL175
112
TL27
110
TL28A
113
TL2X4W-PT-II
23-24
TL2X4W-TWZ
23-24
TL40
109
TL71
110
TL75
110
TL76
110
TL80A
109
TL81A
109
TL82
113
TL220
110
TL221
110
TL222
110
TL223
110
TL224
110
TL225
121
TL238
110
TL910
109
TL930
109
TL932
109
TL935
109
TL940
109
TL950
109
TL960
109
TL970
109
TLK-220
110
TLK-225
111
TLK281
113
TLK282
113
TLK287
109
TLK289
111
TLK290
111
TLK291
111
TP1
111
TP2
111
TP4
111
TP38
111
TP40
113
TP74
111
TP80
111
TP81
113
TP82
113
TP84
113
TP88
113
TP220
111
TP912
109
TP920
109
TPAK
120
TPS Clamp 50A / 5A
87
TPS Clamp 200A / 20A 87
TPS FLEX 18
87
TPS FLEX 24
87
TPS FLEX 36
87
TPS Shunt 5 A
87
TPS Shunt 20 MA
87
TPS Voltprobe 1 KV
87
TPS Voltprobe 10 V
87
TPS Voltprobe 100 V
87
TPS Voltprobe 400 V
87
TPS Voltprobe 600 V
87
VPS40
76
VPS210-R/G series
76

Fuse and Warranty Information
Product Warranty
Each Fluke product is warranted to be free from defects
in material and workmanship under normal use and
service, for the warranty period listed unless local law
requires a longer period. The warranty period is listed
in the ordering information section of the product
specification and begins on the date of shipment.
This warranty extends only to the original buyer or
end-user customer of a Fluke authorized reseller, and
does not apply to fuses, disposable batteries or to any
product which, in Fluke’s opinion, has been misused,
altered, neglected or damaged by accident or abnormal
conditions of operation or handling. Fluke warrants that
software will operate substantially in accordance with its
functional specifications for 90 days and that it has been
properly recorded on non-defective media. Fluke does
not warrant that software will be error free or operate
without interruption.

Lifetime Warranty

Fuse Replacement Information
A
63mA (slow)
125mA (slow)
250mA (slow)
315 mA
440mA
500mA
630mA
1A
1A
1.25A
3.15A
11A
11A
15A
20A

V
250V
250V
250V
1000V
1000V
250V
250V
600V
500V
600V
500V
1000V
1000V
600V
600V

Size
Part nr
in mm
qty 1
6.35x32
163030
6.35x32
166488
6.35x32
166306
10KA
6.35x32
2279339
10kA
10.3x34.9
943121
1500A
5x20
838151
1500A
5x20
740670
10kA
10.3x34.9
830828
50kA
6.35x 32
2530449
6.35x32
2040349
6.35x32
2030852
17kA
Replaced by 11A, 1000V, 20kA fuse; 803293
20kA
10.3x38.1
803293
100kA
10.3x38.1
892583
Replaced by 15A, 600V, 100kA fuse; part nr. 892583
IR

See the back of your Fluke test tool or user manual for the fuses installed.
For manuals check the Fluke website in the product section.
For Fuse Replacement Guide check the Fluke website in the service section.

Each Fluke 20, 70, 80, 170, 180 and 280 Series DMM
purchased after October 1, 1996 will be free from defects
in material and workmanship for its lifetime. This
warranty does not cover fuses, disposable batteries and
damage from accident, neglect, contamination, misuse or
abnormal conditions of operation or handling, including
overvoltage failures caused by use outside the DMM’s
specified rating, or normal wear and tear of mechanical
components. This warranty covers the original purchaser
only and is not transferable. For ten years from the
date of purchase, this warranty also covers the LCD.
Thereafter, for the lifetime of the DMM, Fluke will replace
the LCD for a fee based on then current component
acquisition costs.
To establish original ownership and prove date of
purchase, please complete and return the registration
card accompanying the product.

Service
Fluke will, at its discretion, repair at no charge, replace
or refund the purchase price of a defective product
purchased through a Fluke authorized sales outlet and at
the applicable international price. Fluke reserves the right
to charge for importation costs of repair/replacement
parts if product purchased in one country is sent for
repair elsewhere.
Send defective product with a description of the
problem to the nearest Fluke Authorized Service Center,
postage and insurance prepaid. Fluke will pay return
transportation for product repaired or replaced inwarranty. Before making any non-warranty repair, Fluke
will estimate cost and obtain authorization, then invoice
you for repair and return transportation.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING
LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.
AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO
EXTEND ANY DIFFERENT WARRANTY ON FLUKE’S
BEHALF.
Since some states do not allow the exclusion or
limitation of an implied warranty or of incidental or
consequential damages, this limitation of liability may
not apply to you.

123

Fluke Precision
Measurement products

Total Solutions in Precision
Measurement Catalog
A variety of products covering DC/LF
Electrical Calibration, Power Calibration,
Calibration Software, Pressure Calibration,
Time and Frequency, Temperature and
Humidity Calibration including Hart Scientific, as well as
Data Acquisition and Gener al Purpose Test products like
arbitrary waveform generators and VXI products.
To get a copy, please click “Request a catalog” on your local
Fluke web site.

About Fluke
Networks
Fluke Networks provides innovative
solutions for the installation and
certification, testing, monitoring and
analysis of copper, fiber and wireless
networks used by enterprises and
telecommunications carriers.
The company’s comprehensive line of
Network SuperVision™ Solutions provide
network installers, owners, and maintainers
with superior vision, combining speed,
accuracy and ease of use to optimize
network performance. Headquartered
in Everett, Washington, the company
distributes its products in more than 50
countries. More information can be found
by visiting Fluke Networks’ Web site at
www.flukenetworks.com

Fluke. Keeping your world
up and running. ®
124



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : dtp1
Create Date                     : 2010:04:26 15:58:45+02:00
Modify Date                     : 2010:04:26 15:58:45+02:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Producer                        : Acrobat Distiller 9.3.2 (Macintosh)
Format                          : application/pdf
Creator                         : dtp1
Title                           : TTC-2010_Cover-Backcover-ENG.indd
Creator Tool                    : Adobe InDesign CS4 (6.0.4)
Metadata Date                   : 2010:04:19 10:57:51+02:00
Document ID                     : uuid:ce3aaa0b-4a0c-9c4e-81f2-24bbaa66c672
Instance ID                     : uuid:62c7c05a-5da6-614b-933c-4a2be9ce8252
Page Count                      : 125
EXIF Metadata provided by EXIF.tools

Navigation menu