440398 Catalog

121283-Attachment 121283-Attachment 121283-Attachment 000334 Batch8 unilog cesco-content

2014-09-27

: Pdf 440398-Catalog 440398-Catalog 000334 Batch8 unilog

Open the PDF directly: View PDF PDF.
Page Count: 41

Download440398-Catalog
Open PDF In BrowserView PDF
Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

TW Series — 22mm NEMA Style Pushbuttons

Signaling Lights
Relays & Sockets

Key features:

UL Listed
File No. E68961

CSA Approved
File No. LR21451

IDEC has your 22mm switching needs covered.
Button styles include flush, extended, mushroom, or square and all bodies are
crafted from fracture-resistant nylon.
All illuminated units feature two lense styles, one that maximizes light dispersion, the other accommodates direct lens engraving.

Timers

•	 TW NEMA Style Switches with snap-on contacts
•	 Corrosion resistant octagonal chrome plated locking bezel
•	 Snap-on 10A contact blocks
•	 Incandescent or LED illumination
•	 Slow make, double break, self cleaning contacts
•	 Modular construction for maximum flexibility
•	 NEMA 4X and IP65 watertight/oiltight panel
•	 Available assembled or as sub-components
•	 Large M3.5 screw terminals with captive sems plate

Self cleaning contact mechanisms allow for a wide current rating, 5mA to 10A,
which reduces the need for various contact materials.
When looking for a 22mm switch that is durable, easy to use, and versatile, then
IDEC’s TW series is your solution.

File No. DK95-01696

Contactors
Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) • USA & Canada

611

Switches & Pilot Devices

Switches & Pilot Devices

ø22mm - TW Series
Conforming to Standards

®

CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot
lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380,
400/440, 480V)
UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights
and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440,
480V)
TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110,
115, 120, 200/220, 230, 240, 380, 400/440, 480V)

Certificate No.
2030010305027380

File No. LR21451

Specifications

Registration No: J9551802 (E-Stops)
Registration No: J9551803 (All other switches)
Registration No: J9551804 (Pilot Lights)

Timers

Relays & Sockets

Signaling Lights

File No. E68961

Operating Temperature

Operation: –25 to +50°C (without freezing), Storage: –40 to +80°C (without freezing)

Vibration Resistance

5 to 55Hz, 100m/sec2 (10g) conforming to IEC6068-2-6

Shock Resistance

1000m/sec2 (100g) conforming to IEC6068-2-7

Electric Shock Protection

Class 0 conforming to IEC60536

Degree of Protection
(conforming to IEC60529)
(conforming to NEMA ICS6-110)

IP65 from front of the panel; (IP54 for key switches)
IP20 (Type HW-F contact block)
Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (Type 1, 2, 3R, 5, 12, 13 for key switches)

Mechanical Life

Momentary pushbuttons: 5,000,000 (900 operations per hour)
All other switches: 500,000

Pollution Degree (conforming to IEC60947-1)

3 for switches not using a transformer, 2 for switches using a transformer

Rated Operational Characteristics

AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB)
DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC)
DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB)

Rated Insulation Voltage

600V

Rated Switching Over-Voltage

Less than 4kV, conforming to IEC60947-1

Rated Impulse Withstanding Voltage

4kV for contact circuit, 2.5kV for lamp circuit

Rated Thermal Current

10 Amp

Minimum Switching Capacity

5 mA at 3V AC/DC

Contact Operation

Slow break NC or slow make NO, self-cleaning

Recommended Terminal Torque

0.8 N m (7.1 in lb.)

External Short-Circuit Protection

10A 250V fuse conforming to IEC60269-1

Applicable Wire Size

Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG

Contact Resistance

Initial contact resistance of 50mΩ or less

Contact Gap

4mm (NO and NC), 2mm (NO-EM and NC-LB)

Electrical Reliability

MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA)

Lamp Ratings

Incandescent: 1 W
LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max
1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor)
40 A (40 ms)

Contact Material

Silver

Contact Ratings

Horsepower Rating
Maximum Inrush Current

Pushbuttons
Illuminated Pushbuttons
Selector Switches
Illuminated Selector Switches
Pushbutton Selectors

Characteristics

Contactors
Terminal Blocks

EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14

Approvals

Operational Voltage

Contact Block

Type HW-C/HW-F

Rated Insulation Voltage

600V

Rated Continuous Current

10A

Contact Ratings by Utilization Category
IEC 60947-5-1

AC-15 (A600)
DC-13 (P600)

Circuit Breakers

Contact Ratings by Utilization Category

612 	

AC50/60Hz
Operational Current
DC

	

24V

48V

50V

110V

220V

440V

AC-12 Control of resistive loads and solid state loads

10A

—

10A

10A

6A

2A

AC-15 Control of electromagnetic loads (> 72VA)

10A

—

7A

5A

3A

1A

DC-12 Control of resistive loads and solid state loads

8A

5A

—

2.2A

1.1A

—

DC-13 Control of electromagnets

5A

2A

—

1.1A

0.6A

—

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Non-Illuminated Pushbuttons (Assembled)

Signaling Lights

A

B

( )

W

1

10

( )

–

Relays & Sockets

Assembled Pushbuttons
B

Function

Button Color

B:	 Momentary	
O:	 Maintained	
K:	 Key On/Off Lock

B:	 Black	
R:	 Red	

G:	 Green	
S:	 Blue	

W:	White	
Y:	 Yellow

Terminal Style

Bezel Shape

Timers

Blank:  Standard	
N:  Fingersafe (IP20)

Blank: Octagonal	
F:	 Full Shroud	
G:	 Mushroom Shroud	
Q:	 Square

Contact Arrangement
10:  1NO	
	 01:  1NC	
20:  2NO	
	 02:  2NC	
11:  1NO-1NC		 22:  2NO-2NC

1:	
2:	
3:	
4:	

Contactors

Button Shape
Flush	
Extended	
Mushroom Head Ø 29mm	
Mushroom Head Ø 40mm

Series Designation
Terminal Blocks

W:	TW Series

To be used for interpreting part numbers only, not for part number development.

Circuit Breakers

800-262-IDEC (4332) • USA & Canada

613

Switches & Pilot Devices
Non-Illuminated Pushbuttons (Assembled) continued

Non-Illuminated Pushbuttons
Style

Flush

Contactors

Contacts

Momentary Action
ABW110-j
ABW101-j
ABW111-j
ABW120-j
ABW102-j

Maintained Action

Color

Code

AOW110-j
AOW101-j
AOW111-j
AOW120-j
AOW102-j

Black

B

Green

G

Red

R

Extended

1NO
1NC
1NO-1NC
2NO
2NC

ABW210-j
ABW201-j
ABW211-j
ABW220-j
ABW202-j

AOW210-j
AOW201-j
AOW211-j
AOW220-j
AOW202-j

Recessed

1NO
1NC
1NO-1NC
2NO
2NC

ABFW110-j
ABFW101-j
ABFW111-j
ABFW120-j
ABFW102-j

AOFW110-j
AOFW101-j
AOFW111-j
AOFW120-j
AOFW102-j

Extended with Full
Shroud

1NO
1NC
1NO-1NC
2NO
2NC

ABFW210-j
ABFW201-j
ABFW211-j
ABFW220-j
ABFW202-j

AOFW210-j
AOFW201-j
AOFW211-j
AOFW220-j
AOFW202-j

Ø 29mm 	
Mushroom Head

1NO
1NC
1NO-1NC
2NO
2NC

ABW310-j
ABW301-j
ABW311-j
ABW320-j
ABW302-j

AOW310-j
AOW301-j
AOW311-j
AOW320-j
AOW302-j

Ø 40mm 	
Mushroom Head

1NO
1NC
1NO-1NC
2NO
2NC

ABW410-j
ABW401-j
ABW411-j
ABW420-j
ABW402-j

AOW410-j
AOW401-j
AOW411-j
AOW420-j
AOW402-j

Ø 40mm 	
Mushroom Head
with Full Shroud

1NO
1NC
1NO-1NC
2NO
2NC

ABGW410-j
ABGW401-j
ABGW411-j
ABGW420-j
ABGW402-j

AOGW410-j
AOGW401-j
AOGW411-j
AOGW420-j
AOGW402-j

Square Flush

1NO
1NC
1NO-1NC
2NO
2NC

ABQW110-j
ABQW101-j
ABQW111-j
ABQW120-j
ABQW102-j

AOQW110-j
AOQW101-j
AOQW111-j
AOQW120-j
AOQW102-j

Square Extended

1NO
1NC
1NO-1NC
2NO
2NC

ABQW210-j
ABQW201-j
ABQW211-j
ABQW220-j
ABQW202-j

AOQW210-j
AOQW201-j
AOQW211-j
AOQW220-j
AOQW202-j

Keylock Push On/
Off

1NO
1NC
1NO-1NC
2NO
2NC

AKW210
AKW201
AKW211
AKW220
AKW202

–

Circuit Breakers

Terminal Blocks

j Button Color Codes
1NO
1NC
1NO-1NC
2NO
2NC

Timers

Relays & Sockets

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series

1. 	 In place of  j, specify the Button Color Code from table.
2.	 For sub-assembled part numbers, see next page.
3.	 For accessories, see page 643.
4.	 For dimensions, see page 645.
5.	 Keyed switches are supplied with two keys. All units are keyed alike.

614 	

	

www.IDEC.com

Blue

S

Yellow

Y

White

W

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Non-Illuminated Pushbuttons (Sub-Assembled)
Contact Blocks

+

Style

+

Button

Buttons
Part Number
Momentary

Part Number

Round Flush

AOW-100

HW-C10

HW-C01

HW-C10R
(early make)

HW-C01R
(late break)

HW-F10

HW-F01

HW-F10R
(early make)

HW-F01R
(late break)

Fingersafe
(IP20), CE
marked

ABW2B-j
AOFW-200

Ø 29mm Mushroom
Ø 40mm, Ø 29mm
Mushroom Head

1NC

Dummy Block
ABW3B-j

TW-DB

AOW-300
Ø 40mm Mushroom

Ø 40mm Mushroom
Head with Full Shroud

1.	 Dummy blocks (no contacts) are used with an odd
number of contact blocks.
2.	 Use of early and late break contacts creates a make
before break function

ABW4B-j
AOGW-400

j Button Color Codes
Square Flush
ABQW1B-j

Square Flush/Extended
ABQW-100

AOQW-100

Keylock Push On/Off

ABQW2B-j

Color

Code

Black

B

Green

G

Red

R

Blue

S

Yellow

Y

White

W

Terminal Blocks

Square Extended

—

Contactors

ABGW-400

Timers

ABW-300

Relays & Sockets

Round Extended

ABFW-200

1NO

Standard Exposed Screw

ABW1B-j

Round with Full Shroud/
Recessed

Part Number

Style

Round Flush/Extended
ABW-100

Complete Part

Contact Blocks
Style

Maintained

=

Signaling Lights

Operators

Operator

	

AKW-200
In place of j specify the button color code from table

Circuit Breakers

800-262-IDEC (4332) • USA & Canada

615

Switches & Pilot Devices

Switches & Pilot Devices

ø22mm - TW Series

Signaling Lights

Stop Switches (Assembled)

Relays & Sockets

Assembled Stop Switches
A

V

(L)

W

4

(B)

(99)

11

(D)

Function

Lamp Voltage

(full voltage illuminated units only)

V:	 Pushlock Turn Reset
Y:	Push-Pull
X:	 Pushlock Key Reset

	 6V:	
	 12V:	
	 24V:	
	120V:	
	240V:	

Timers

Illumination
Blank: None
L:	Illuminated

W: TW Series

A:	 Amber	 R:	Red	 W:	 White
G:	 Green	 S:	Blue	 Y:	 Yellow
B:	Black

Button/Lens Size

Contact Terminal Style

3:	 29mm Mushroom
4:	 40mm Mushroom

Blank:	 Standard
N:	 Fingersafe (IP20)

Lens Type

Lamp Type

Contactors

(illuminated units only)

Terminal Blocks

6V AC/DC
12V AC/DC
24V AC/DC
120V AC (LED only)
240V AC (LED only)

Button/Lens Color

Series Designation

Circuit Breakers

(N) – R – (24V)

(illuminated units only)

Blank: Standard (ribbed)
B:	 Engravable (smooth with insert)

Blank: Incandescent
D: LED

Illuminated Circuit

Contact Arrangement

(illuminated unit only)
	
	
	
	

99:	
126:	
246:	
486:	

10:	1NO	
01:	1NC
20:	2NO	
02:	2NC
11:	1NO/1NC	 22:	2NO/2NC

Full Voltage (lamp determines voltage)
120V AC Step Down Transformer
240V AC Step Down Transformer
480V AC Step Down Transformer

To be used for interpreting part numbers only, not for part number development.

616 		

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Stop Switches (Assembled), continued
Non-Illuminated Stop Switches

j Button Color Codes

Style

Contacts
1NO
1NC
1NO-1NC
2NO
2NC

Ø 40mm Pushlock
Turn Reset*

Ø 40mm Push-Pull

Code

AVW410-R*
AVW401-R*
AVW411-R*
AVW420-R*
AVW402-R*

Black

B

Green

G

Red

R

AVW310-R*
AVW301-R*
AVW311-R*
AVW320-R*
AVW302-R*

1NO
1NC
1NO-1NC
2NO
2NC

AYW410-j
AYW401-j
AYW411-j
AYW420-j
AYW402-j
AXW410AXW401AXW411AXW420AXW402-

R*
R*
R*
R*
R*

Part Number

Full Voltage

1NO-1NC
2NO
2NC

AVLW49911n-R*-l
AVLW49920n-R*-l
AVLW49902n-R*-l

Transformer

1NO-1NC
2NO
2NC

AVLW3m11n-R*
AVLW3m20n-R*
AVLW3m02n-R*

Full Voltage

1NO-1NC
2NO
2NC

AVLW39911n-R*-l
AVLW39920n-R*-l
AVLW39902n-R*-l

Transformer

1NO-1NC
2NO
2NC

AYLW4 m 11n-k
AYLW4 m 20n-k
AYLW4 m 02n-k

Full Voltage

1NO-1NC
2NO
2NC

AYLW49911n-k-l
AYLW49920n-k-l
AYLW49902n-k-l

Ø 40mm Push-Pull

Code

Amber

A

Green

G

Red

R

Blue

S

White

W

Voltage

Code

6V AC/DC

6V

12V AC/DC

12V

24V AC/DC

24V

120V AC

120V (LED only)

240V AC

240V (LED only)

m Transformer Voltage Codes
Voltage

Code

120VAC
240VAC
480VAC

126
246
486

Transformers step down to 6V.

n Lamp Type Codes
Lamp

Code

Incandescent

Blank

LED

D
Terminal Blocks

AVLW4 m 11n-R*
AVLW4 m 20n-R*
AVLW4 m 02n-R*

Ø 29mm Pushlock
Turn Reset

Color

Contactors

Transformer

1NO-1NC
2NO
2NC

Ø 40mm Pushlock
Turn Reset Type

Y

Timers

Contacts

Yellow

l Full Voltage Codes

Illuminated Stop Switches
Type

S
W

k LED/Lens Color Codes

1. 	 *Available in Red only.
2. 	 In place of j, specify the Button Color Code from table.
3.	 For sub-assembled part numbers, see next page.
4.	 For accessories, see page 643.
5.	 For dimensions, see page 645.

Style

Blue
White

Relays & Sockets

1NO
1NC
1NO-1NC
2NO
2NC

1NO
1NC
1NO-1NC
2NO
2NC

Ø 40mm Pushlock
Key Reset *

Color

Signaling Lights

Ø 29mm Pushlock
Turn Reset*

Part Number

800-262-IDEC (4332) • USA & Canada

Circuit Breakers

1. *Available in red only.
2. 	 In place of k, specify the Lens Color Code (see table above).
3.	 In place of l, specify the Full Voltage Code (lamp voltage) (see table above). 	
4. 	 In place of m, specify the Transformer Voltage Code (see table above).
5. In place of n, specify the Lamp Type Code from table above.
6.	 For sub-assembly part numbers, see next page.
7.	 For accessories, see page 643.
8.	 For dimensions, see page 645.

617

Switches & Pilot Devices

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series

Stop Switches (Sub-Assembled)
Transformer/
Adaptor*

+

Contacts

+

Lamp Holder

+

Operator

Lamp

+ Button or Lens =

Operators
Style

Buttons

Contact Blocks

Part Number

Style

Non-Illuminated Illuminated

Ø 40mm Pushlock Turn Reset

Part Number

Style
LED

AVW4B-R*
AVW-300

AVLW3-0600
Incandescent

Ø 29mm Pushlock Turn Reset
Ø 40mm Push-Pull

AVW3B-R*
AYW-400

Voltage

Part Number

6V AC/DC

LSTD-6k

12V AC/DC

LSTD-1k

24V AC/DC

LSTD-2k

120V AC

LSTD-H2k

240V AC

LSTD-M4k

6V AC/DC

IS-6

12V AC/DC

IS-12

24V AC/DC

IS-24

1.	 In place of k, specify the LED color code.
2.	 The LED contains a current-limiting resistor and a
protection diode.

AYLW4-0600

Ø 40mm Push-Pull
Timers

Complete Part

*Not applicable for full voltage units

Ø 29/Ø 40mm Pushlock Turn Reset
Relays & Sockets

+

Ø 40mm Pushlock
Key Reset

j Button Color Codes
AYW4B-j
AXW-300

—
Ø 40mm Pushlock Key Reset

Contactors

AXW4B-R*

Circuit Breakers

Terminal Blocks

1.	 *Available in Red only
2.	 In place of j, specify the button color code from table.

618 		

www.IDEC.com

Color

Code

Black

B

Green

G

Red

R

Blue

S

White

W

Yellow

Y

k LED/Lens Color Codes
Color

Code

Amber

A

Green

G

Red

R

Blue

S

White

W

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Illuminated Stop Switches (Sub-Assembled) continued
Lenses

Transformers/Full Voltage Modules
Style

Style

Part Number
Standard

Engravable

Description

Full Size Transformer
Standard

Ø 29mm Head Pushlock Turn Reset
AVLW3LU-R*

AVLW3BLU-R*
Fingersafe
Half Size Transformer

AVLW4LU-R*

AVLW4BLU-R*

Ø 40mm Head Push Pull
AYLW4BLU-k

Full voltage model (use with even
number of contacts)

1.	 In place of k, specify the lens color code from table on previous page.
2.	 *Available only in red
3.	 Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert.

Full voltage model (use with odd
number of contacts)

Lamp Circuit Components
Style

Application

TW-T246B

480V AC

TW-T486B

120V AC

TW-F126B

240V AC

TW-F246B

480V AC

TW-F486B

120V AC

TW-T126SB

240V AC

TW-T246SB

Standard

TW-DA1B

Fingersafe

TW-DA1FB

Standard

HW-DA1B

Fingersafe

HW-DA1FB

Part Number
Timers

Short Lamp Holder
Used with a Half-size
Transformer and one
contact block

TW-T126B

240V AC

Relays & Sockets

AYLW4LU-k

120V AC

Signaling Lights

Ø 40mm Head Pushlock Turn Reset

Part Number

TW-LH1
All Transformers step down to 6V (use 6V lamp).

TW-LH2

Used with TW-LH2
holder when using four
contact blocks

HW-LH3

Contact Blocks
Style
Standard Exposed Screw

Lead Holder

Part Number
1NO

1NC

HW-C10

HW-C01

HW-C10R
(early make)

HW-C01R
(late break)

HW-F10

HW-F01

HW-F10R
(early make)

HW-F01R
(late break)

Terminal Blocks

Fingersafe (IP20), CE marked

Contactors

Long Lamp Holder

Used with Full-size
Transformer and two
contact blocks
Used with Half-size
Transformer and three
contact blocks
Used with Full Voltage
Adaptor and two contact
blocks

Dummy Block

TW-DB
Circuit Breakers

1.	 Dummy blocks (no contacts) are used with an odd number of contact blocks.
2.	 Use of early and late break contacts creates a make before break function

800-262-IDEC (4332) • USA & Canada

619

Switches & Pilot Devices

Switches & Pilot Devices

ø22mm - TW Series

Relays & Sockets

Signaling Lights

Pilot Lights (Assembled)

Assembled Pilot Lights
A

P

(Q)

W

1

(B)

(99)

(D) – R – (24V)

Function

Lamp Voltage

(Full Voltage Units Only)

Blank: Octagonal (round lenses)	
Q:	Square

	 6V:	
	 12V:	
	 24V:	
	120V:	
	240V:	

Series Designation

Lens Color Code

W:	TW Series

1: Flat	
2: Dome

A:	 Amber	
G:	 Green	
R:	 Red	
S:	 Blue	
W:	White	
Y:	 Yellow

Lens Type

Lamp Type

Blank: Standard (ribbed)	
B: Engravable (smooth with insert included)

Blank: Incandescent 	
D: LED

Bezel Shape

Lens Shape

Illumination Circuit
	
	
	
	

99:	
126:	
246:	
486:	

Circuit Breakers

Terminal Blocks

Contactors

Timers

P:	Pilot Light

Full Voltage (lamp determines voltage)	
120V AC Step Down Transformer	 	
240V AC Step Down Transformer	
480V AC Step Down Transformer

1.	 Use only when interpreting part numbers. Do not use for developing part numbers.
2.	 All transformers step down to 6V.

620 	

	

www.IDEC.com

6V AC/DC	
12V AC/DC	
24V AC/DC	
120V AC (LED only)	
240V AC (LED only)

	

	

	

	

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Pilot Lights (Assembled) continued
Assembled Pilot Lights

k Lens Color Codes

Style

Type

Voltage

Part Number

Color

Code

Transformer

120VAC
240VAC
480VAC

APW1126m-k
APW1246m-k
APW1486m-k

Amber

A

Green

G

Red

R

—

APW199m-k-l

Round Flat
Full Voltage

120VAC
240VAC
480VAC

APW2126m-k
APW2246m-k
APW2486m-k

Full Voltage

—

APW299m-k-l

Transformer

120VAC
240VAC
480VAC

APQW1B126m-k
APQW1B246m-k
APQW1B486m-k

Dome

Full Voltage

—

APQW1B99m-k-l

1. 	 In place of k, specify the Lens Color Code from table below.
2. 	 In place of l, specify the Full Voltage Code from table below.
3. In place of m, specify the Lamp Type Code from table below.
4.	 For accessories, see page 643.
5.	 For dimensions, see page 645.
6.	 For sub-assembly part numbers, see next page.
7.   Yellow pilot light comes with white LED.

Yellow

Y

l Full Voltage Codes
Voltage

Code

6V AC/DC

6V

12V AC/DC

12V

24V AC/DC

24V

120V AC

120V (LED only)

240V AC

240V (LED only)

Relays & Sockets

Square Flat

S
W
Signaling Lights

Transformer

Blue
White

m Lamp Type Codes
Lamp

Code

Incandescent

Blank

LED

D

Timers
Contactors
Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) • USA & Canada

621

Switches & Pilot Devices

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series

Pilot Lights (Sub-Assembled)
Transformer

+

Operator

+

Lamp

Lens

Operators
Style

Lamps
Part Number

Complete Part

k LED/Lens Color Codes

Style
LED

APW-199

Incandescent

Square

UPQW-199

Timers

	

Voltage

Part Number

Color

Code

6V AC/DC

LSTD-6k

Amber

A

12V AC/DC

LSTD-1k

Green

G

24V AC/DC

LSTD-2k

Red

R

120V AC

LSTD-H2k

Blue

S

240V AC

LSTD-M4k

White

W

6V AC/DC

IS-6

Yellow

Y

12V AC/DC

IS-12

24V AC/DC

IS-24

Same operator is used for full voltage as for 	
transformer completed units.

Part Number
Standard

Description

Standard

Engravable

Dome
Contactors

APW2LU-k

Fingersafe

—

All Transformers step down to 6V (use 6V lamp).

Round Flat
APW1LU-k

APW1BLU-k

—

APQW1BLU-k

Square Flat

Circuit Breakers

1.	 In place of k, specify the Lens Color Code from table.
2.	 Standard lenses have a ribbed lens to enhance light
dispersion. Marking lenses are smooth and include an
engravable insert.

622 	

	

If clear lens is desired, use
white marking lens and
remove engraving insert

Transformers
Style

Style

	

1.	 In place of k, specify the LED color code.
2.	 The LED contains a current-limiting resistor and a
protection diode.
3.  Yellow LED not available. Use white LED.

Lenses

Terminal Blocks

=

* Transformer not required for full voltage units.

Round Dome/Flat

Relays & Sockets

+

www.IDEC.com

Part Number

120V AC

TW-T126B

240V AC

TW-T246B

480V AC

TW-T486B

120V AC

TW-F126B

240V AC

TW-F246B

480V AC

TW-F486B

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Illuminated Pushbuttons (Assembled)

Signaling Lights

A

L

(F)

W

2

(B)

99

11

Function

(N) – R – (24V)
Lamp Voltage

(Full Voltage Units Only)

L:	Momentary Action	
OL:	Maintained Action

Blank: Octagonal (round lenses)	
F: Full Shroud (round lenses)	
Q: Square

Timers

	 6V:	 6V AC/DC	
	 12V:	 12V AC/DC	
	 24V:	 24V AC/DC	
	120V:	 120V AC (LED only)	
	240V:	 240V AC (LED only)

Bezel Shape

Lens Code

W: TW series

Lens Shape/Size
2: Standard Extended (round or square)	
3: 29mm Mushroom	
4: 40mm Mushroom

	
	

	

Contactors

A:	 Amber	
G:	 Green	
R:	 Red	
S:	 Blue	
W:	White	
Y:	 Yellow

Series Designation

Contact Terminal Style
Blank:	 Standard	
N:	 Fingersafe	

Lens Type
Blank: Standard (ribbed)	
B: Engravable (smooth with insert)

Lamp Type
Terminal Blocks

Blank:		
Incandescent Lamp	
D:	 LED Lamp

Illumination Circuit
	 99:	
	126:	
	246:	
	486:	

(D)

Relays & Sockets

Assembled Illuminated Pushbuttons

Full Voltage (lamp determines voltage) 	
120V AC Step Down Transformer	
240V AC Step Down Transformer	
480V AC Step Down Transformer

Contact Arrangement
10: 1NO	
	
20: 2NO	
	
11: 1NO-1NC	 	

01: 1NC	
02: 2NC	
22: 2NO-2NC

Circuit Breakers

1.	 Use only when interpreting part numbers. Do not use for developing part numbers.
2.	 Transformers step down to 6V.

800-262-IDEC (4332) • USA & Canada

623

Switches & Pilot Devices

Switches & Pilot Devices

ø22mm - TW Series

Illuminated Pushbuttons (Assembled)
Illuminated Pushbuttons

k LED/Lens Color Codes

Style

Signaling Lights

Extended Lens

Relays & Sockets

Extended Lens with Full Shroud

Contacts

Transformer

Timers
Contactors
Terminal Blocks

Square Extended

ALW2 m 11n-k
ALW2 m 20n-k
ALW2 m 02n-k

Maintained
AOLW2 m 11n-k
AOLW2 m 20n-k
AOLW2 m 02n-k

Full Voltage

ALW29911n-k-l
ALW29920n-k-l
ALW29902n-k-l

AOLW29911n-k-l
AOLW29920n-k-l
AOLW29902n-k-l

Transformer

1NO-1NC
2NO
2NC

ALFW2 m 11n-k
ALFW2 m 20n-k
ALFW2 m 02n-k

AOLFW2 m 11n-k
AOLFW2 m 20n-k
AOLFW2 m 02n-k

Transformer

Full Voltage

ø40mm Mushroom Lens

Momentary

1NO-1NC
2NO
2NC

Full Voltage

ø29mm Mushroom Lens

1NO-1NC
2NO
2NC

Part Number

Transformer

1NO-1NC
2NO
2NC

1NO-1NC
2NO
2NC

ALFW29911n-k-l
ALFW29920n-k-l
ALFW29902n-k-l

ALW3 m 11n-k
ALW3 m 20n-k
ALW3 m 02n-k

AOLFW29911n-k-l
AOLFW29920n-k-l
AOLFW29902n-k-l

AOLW3 m11n-k
AOLW3 m20n-k
AOLW3 m 02n-k

1NO-1NC
2NO
2NC

ALW39911n-k-l
ALW39920n-k-l
ALW39902n-k-l

AOLW39911n-k-l
AOLW39920n-k-l
AOLW39902n-k-l

1NO-1NC
2NO
2NC

ALW4 m 11n-k
ALW4 m 20n-k
ALW4 m 02n-k

AOLW4 m11n-k
AOLW4 m20n-k
AOLW4 m 02n-k

Full Voltage

1NO-1NC
2NO
2NC

ALW49911n-k-l
ALW49920n-k-l
ALW49902n-k-l

AOLW49911n-k-l
AOLW49920n-k-l
AOLW49902n-k-l

Transformer

1NO-1NC
2NO
2NC

ALQW2B m11n-k
ALQW2B m20n-k
ALQW2B m02n-k

AOLQW2B m11n-k
AOLQW2B m20n-k
AOLQW2B m02n-k

Full Voltage

1NO-1NC
2NO
2NC

ALQW2B9911n-k-l
ALQW2B9920n-k-l
ALQW2B9902n-k-l

AOLQW2B9911n-k-l
AOLQW2B9920n-k-l
AOLQW2B9902n-k-l

Circuit Breakers

1. 	 In place of k, specify the Lens Color Code (see table). Mushroom lenses not available in yellow.
2.	 In place of l, specify the Full Voltage Code (lamp voltage) (see table). 	
3. 	 In place of m, specify the Transformer Voltage Code (see table).
4. In place of n, specify the Lamp Type Code from table.
5.	 For sub-assembly part numbers, see next page.
6.	 For accessories, see page 643.
7.	 For dimensions, see page 645.
8.	 Light is independent of switch position.
9.  Yellow pushbutton comes with white LED.

624 	

	

www.IDEC.com

Color

Code

Amber

A

Green

G

Red

R

Blue

S

White

W

Yellow

Y

1.	 Mushroom lenses not 	
available in yellow.
2.  Yellow pushbutton comes
with white LED.

l Full Voltage Codes
Voltage

Code

6V AC/DC

6V

12V AC/DC

12V

24V AC/DC

24V

120V AC

120V (LED only)

240V AC

240V (LED only)

m Transformer Voltage Codes
Voltage

Code

120VAC

126

240VAC

246

480VAC

486

   	 Transformers step down to 6V
(use 6V lamp).

n Lamp Type Codes
Lamp

Code

Incandescent

Blank

LED

D

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Illuminated Pushbuttons (Sub-Assembled)
Transformer/
Adaptor*

+

Contacts

+

Lamp Holder

+

Operator

+

Lamp

+

Lens

=

Complete Part

Operators

Signaling Lights

*Not applicable for full voltage units

Lamps
Style

Style

Part Number
Momentary

Maintained
LED

ALW-0600

Extended

ALFW-0600

ø29mm/ø40mm
Mushroom

AOLFW-0600

ALW3-0600

AOLW3-0600

Incandescent

Part Number
LSTD-6k

12V AC/DC

LSTD-1k

24V AC/DC

LSTD-2k

120V AC

LSTD-H2k

240V AC

LSTD-M4k

6V AC/DC

IS-6

12V AC/DC

IS-12

24V AC/DC

IS-24

Relays & Sockets

Extended with
Full Shroud

AOLW-0600

Voltage
6V AC/DC

1.	 In place of k, specify the LED color code.
2.	 The LED contains a current-limiting resistor and a
protection diode.

Lamp Circuit Components
Style
AOLQW-2B0600

Application

Short Lamp Holder

Lenses
Style

Used with a Half-size
Transformer and one
contact block

TW-LH1

Used with Full-size
Transformer and two
contact blocks
Used with Half-size
Transformer and three
contact blocks
Used with Full Voltage
Adaptor and two contact
blocks

TW-LH2

Used with TW-LH2
holder when using four
contact blocks

HW-LH3

Part Number
Standard

Engravable

Round Extended

ALW2LU-k

ALW2BLU-k

ø 29mm 	
Mushroom Head*

ALW3LU-k

ALW3BLU-k

Contactors

Long Lamp Holder

Lead Holder

ALW4LU-k

ALW4BLU-k

Terminal Blocks

ø 40mm 	
Mushroom Head*

Part Number
Timers

ALQW-2B0600

Square/Extended

k LED/Lens Color Codes
Square Extended

—

ALQW2BLU-k

Code

Color

Code

Amber

A

Blue

S

Green

G

White

W

Red

R

Yellow

Y

Circuit Breakers

1.	 In place of k, specify the lens color code from table on the bottom right.
2.	 *Mushroom lens not available in yellow.
3.	 Standard lenses have ribbed pattern, Engravable lenses are smooth and include an 	
engravable insert.

Color

Yellow LED not available. Use white LED.

800-262-IDEC (4332) • USA & Canada

625

Switches & Pilot Devices

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series

Illuminated Pushbuttons (Sub-Assembled) continued
Transformers/Full Voltage Modules

Contact Blocks
Style
Standard Exposed Screw

Fingersafe (IP20), CE marked

Style

Part Number
1NO

1NC

HW-C10

HW-C01

HW-C10R
(early make)

HW-C01R
(late break)

HW-F10

HW-F01

HW-F10R
(early make)

HW-F01R
(late break)

Description

Full Size Transformer
Standard

Fingersafe

Part Number

120V AC

TW-T126B

240V AC

TW-T246B

480V AC

TW-T486B

120V AC

TW-F126B

240V AC

TW-F246B

480V AC

TW-F486B

Half Size Transformer
120V AC

TW-T126SB

240V AC

TW-T246SB

Standard

TW-DA1B

Fingersafe

TW-DA1FB

Standard

HW-DA1B

Fingersafe

HW-DA1FB

Dummy Block

Relays & Sockets

TW-DB

Full voltage model (use with
even number of contacts)

1.	 Dummy blocks (no contacts) are used with an odd number of contact blocks.
2.	 Use of early and late break contacts creates a make before break function

Timers

Full voltage model (use with
odd number of contacts)

Circuit Breakers

Terminal Blocks

Contactors

All Transformers step down to 6V (use 6V lamp).

626 	

	

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Non-Illuminated Selector Switches (Assembled)

Signaling Lights
Relays & Sockets

Assembled Selector Switches
A

S

W

3

(1)

(L)

20

(N) – 304

Function

Circuit Number

S:	 Selector Switch

(Standard circuits shown on following
pages and 635.)

Series Designation

Blank: standard	
N: Fingersafe (IP20)

Number of Positions
2:	 2-Position	
3:	 3-Position	
4:  4-Position	
5:  5-Position

Contact Arrangement Code

Blank:  Maintained	
1:	 Spring return from Right (2 or 3 position)	
2:	 Spring return from Left (2 or 3 position)	
3:	 2-Way spring return from Left and Right 	
     (3 position only)

Contactors

10:	 1NO	
01:	 1NC	
20:	 2NO	
02:	 2NC	
40:	 4NO	
04:	 4NC	
11:	 1NO-1NC	22:	 2NO-2NC	

Spring Return Action

Operator Style Code
Blank:	
Knob Operator	
L:	 Lever Operator	
K:	 Key Operator	

Terminal Blocks

1.	
2.	
3.	
4.	

Timers

Contacts Terminal Style

W:	TW Series

Use only when interpreting part numbers. Do not use for developing part numbers.
Custom contact configurations available.
Custom key removable codes available.
Portions of part number inside ( ) are optional.

Circuit Breakers

800-262-IDEC (4332) • USA & Canada

627

Switches & Pilot Devices
Non-Illuminated Selector Switches (Assembled) continued

2-Position Selector Switches
Style

Part Number
Operator
Position

Spring Return
from Left

Mounting

Spring Return
from Right

Contact

Maintained

1NO

1
2

O
O

X
O

Knob
Lever
Key

ASW210
ASW2L10
ASW2K10

ASW2110
ASW21L10
ASW21K10

ASW2210
ASW22L10
ASW22K10

1NC

1
2

X
O

O
O

Knob
Lever
Key

ASW201-116
ASW2L01-116
ASW2K01-116

ASW2101-116
ASW21L01-116
ASW21K01-116

ASW2201-116
ASW22L01-116
ASW22K01-116

1NO
1NC

1
2

X
O

O
X

Knob
Lever
Key

ASW211
ASW2L11
ASW2K11

ASW2111
ASW21L11
ASW21K11

ASW2211
ASW22L11
ASW22K11

2NO

1
2

O
O

X
X

Knob
Lever
Key

ASW220
ASW2L20
ASW2K20

ASW2120
ASW21L20
ASW21K20

ASW2220
ASW22L20
ASW22K20

2NC

1
2

X
X

O
O

Knob
Lever
Key

ASW202-104
ASW2L02-104
ASW2K02-104

ASW2102-104
ASW21L02-104
ASW21K02-104

ASW2202-104
ASW22L02-104
ASW22K02-104

2NO
2NC

1
2
3
4

O
X
O
X

X
O
X
O

Knob
Lever
Key

ASW222
ASW2L22
ASW2K22

ASW2122
ASW21L22
ASW21K22

ASW2222
ASW22L22
ASW22K22

2NO
2NC

1
2
3
4

O
O
X
X

X
X
O
O

Knob
Lever
Key

ASW222-111
ASW2L22-111
ASW2K22-111

ASW2122-111
ASW21L22-111
ASW21K22-111

ASW2222-111
ASW22L22-111
ASW22K22-111

L

R

L

R

L

R

L

Circuit Breakers

Terminal Blocks

Contactors

Timers

Relays & Sockets

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series

628 	

	

www.IDEC.com

R

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Non-Illuminated Selector Switches (Assembled) continued
3-Position Selector Switches
Style

Part Number
Spring Return from Right

Spring Return from Left

Spring Return Two-Way

Mounting

Maintained

Contact

Operator Position

2NO

1
2

X
O

O
O

O
X

Knob
Lever
Key

ASW320
ASW3L20
ASW3K20

ASW3120
ASW31L20
ASW31K20

ASW3220
ASW32L20
ASW32K20

ASW3320
ASW33L20
ASW33K20

2NC

1
2

O
X

X
X

X
O

Knob
Lever
Key

ASW302
ASW3L02
ASW3K02

ASW3102
ASW31L02
ASW31K02

ASW3202
ASW32L02
ASW32K02

ASW3302
ASW33L02
ASW33K02

2NO
2NC

1
2
3
4

X
O
O
X

O
O
X
X

O
X
X
O

Knob
Lever
Key

ASW322
ASW3L22
ASW3K22

ASW3122
ASW31L22
ASW31K22

ASW3222
ASW32L22
ASW32K22

ASW3322
ASW33L22
ASW33K22

2NO
2NC

1
2
3
4

X
X
O
O

O
X
X
O

X
O
O
X

Knob
Lever
Key

ASW322-309
ASW3L22-309
ASW3K22-309

ASW3122-309
ASW31L22-309
ASW31K22-309

ASW3222-309
ASW32L22-309
ASW32K22-309

ASW3322-309
ASW33L22-309
ASW33K22-309

2NO
2NC

1
2
3
4

O
O
O
O

X
O
X
O

O
X
O
X

Knob
Lever
Key

ASW322-310
ASW3L22-310
ASW3K22-310

ASW3122-310
ASW31L22-310
ASW31K22-310

ASW3222-310
ASW32L22-310
ASW32K22-310

ASW3322-310
ASW33L22-310
ASW33K22-310

4NO

1
2
3
4

X
O
X
O

O
O
O
O

O
X
O
X

Knob
Lever
Key

ASW340
ASW3L40
ASW3K40

ASW3140
ASW31L40
ASW31K40

ASW3240
ASW32L40
ASW32K40

ASW3340
ASW33L40
ASW33K40

4NC

1
2
3
4

O
X
O
X

X
X
X
X

X
O
X
O

Knob
Lever
Key

ASW304
ASW3L04
ASW3K04

ASW3104
ASW31L04
ASW31K04

ASW3204
ASW32L04
ASW32K04

ASW3304
ASW33L04
ASW33K04

L

C

R

L

C

L

R

C

C

L

R

L

R

C

R

Signaling Lights
Relays & Sockets
Timers

4-Position Selector Switch

5-Position Selector Switch

X
O
O
O

3

Part Number
4

1

2

3

1

2NO
2NC

1
2
3
4

X
O
O
O

4

O
X
O
O

O
O
X
O

O
O
O
X

Knob
Lever

ASW422-411
ASW4L22-411

Maintained

Operator Position

Mounting

1
2
3
4

2

Style
Contact

Operator Position

Mounting

2NO
2NC

Maintained

2

3

O
X
O
O

O
O
O
O

Part Number

4

5

O
O
X
O

O
O
O
X

2
1

Knob
Lever

3

4

5

ASW522-501
ASW5L22-501

Terminal Blocks

Contact

Style

1

Contactors

1.	 The truth table indicates the operating position of contact block when the operator is switched to that position.
	 X = On (closed contacts) 	
O = Off (open contacts)	
X
X   = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions.
2.	 All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately.
3.	 Every key selector switch uses an identical key. The key is removable in any maintained position.
4.	 Custom contact configurations are available, see page 635.

Circuit Breakers

800-262-IDEC (4332) • USA & Canada

629

Switches & Pilot Devices

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series

Non-Illuminated Selector Switches (Sub-Assembled)
Contact Blocks

+

Operator

Knob or Lever*

+

Color Insert*

=

Complete Part†

1. 	 *Not needed with key type switches.
2. 	 †Knob type shown.

Operators

Handles and Inserts
Style

Positions

ASW200
ASW2100

Spring return from left

ASW2200

Maintained, Cam 1
Maintained, Cam 2
Maintained, Cam 3

ASW300-1
ASW300-2
ASW300-3

Spring return from right, Cam 1
Spring return from right, Cam 2

ASW3100-1
ASW3100-2

Spring return from left, Cam 1
Spring return from left, Cam 2

ASW3200-1
ASW3200-2

Spring return from left/right, Cam 1
Spring return from left/right, Cam 2

ASW3300-1
ASW3300-2

4

Maintained, Standard Cam
Maintained, Cam 1

ASW400
ASW400-1

5

Maintained, Standard cam
Maintained, Cam 1

ASW500
ASW500-1

Maintained

ASW2K00

Relays & Sockets
Timers

3

2

Contactors

3

1.	
2.	
3.	
4.	

Spring return from right

ASW21K00

Spring return from left

ASW22K00

Maintained, Cam 1
Maintained, Cam 2
Maintained, Cam 3

ASW3K00-1
ASW3K00-2
ASW3K00-3

Spring return from right, Cam 1
Spring return from right, Cam 2

ASW31K00-1
ASW31K00-2

Spring return from left, Cam 1
Spring return from left, Cam 2

ASW32K00-1
ASW32K00-2

Spring return from left/right, Cam 1
Spring return from left/right, Cam 2

ASW33K00-1
ASW33K00-2

Color

Code

Black*

B

Blue

S

Green

G

Red

R

Yellow

Y

White†

W

Key Switch Black Sleeve

	

Part Number

Knob

ASWHHY-j

Lever

ASWHHL-j

Color
Insert

TW-HC1-j

Contact Blocks
Style
Standard Exposed
Screw

Fingersafe (IP20), CE
marked

Part Number
1NO

1NC

HW-C10

HW-C01

HW-C10R
(early make)

HW-C01R
(late break)

HW-F10

HW-F01

HW-F10R
(early make)

HW-F01R
(late break)

Dummy Block

Replacement Parts
AKW2B-B

TW-DB

1. 	 Push rod color code: 	
Green = NO contact block	
Red = NC contact block.
2. 	 Dummy blocks (no contacts) are used with an odd
number of contact blocks.

*Color inserts not available in black.
†
Knob and lever not available in white.

630 	

Style

Two keys are supplied with every key switch, all are keyed alike, and removable from any maintained position.
Locking rings are included with all operators. Order knobs, levers, and color inserts separately.
Different cams produce different contact actions. For details, see page 635.
Key switch operator supplied with black sleeve.

j Handle/Insert Color Codes

Circuit Breakers

Part Number

Spring return from right

Knob/Lever

Key

Description
Maintained

2

Terminal Blocks

+

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Illuminated Selector Switches (Assembled)

Signaling Lights

Assembled Illuminated Selector Switches
A

SL

W

2

(2)

99

11

(D) (N) – (103) – R – (24V)
Lamp Voltage

(Full Voltage Units Only)

SL:	Illuminated Selector Switch

	 6V:	 6V AC/DC	
	 12V:	 12V AC/DC	
	 24V:	 24V AC/DC	
	120V:	 120V AC (LED only)	
	240V:	 240V AC (LED only)

Series Designation
W: TW series

Number of Positions

Lens Color Code
A:	 Amber	
G:	 Green	
R:	 Red	
S:	 Blue	
W:	White	
Y:	 Yellow

Spring Return Action
Blank: Maintained	
1: Spring return from Right	
2: Spring return from Left	
3: Two-Way spring return from Left and Right

	
	

Timers

2: 2-Position	
3: 3-Position

	

Contact Circuit Number

Full Voltage (lamp determines voltage) 	
120V AC Step Down Transformer	
240V AC Step Down Transformer	
480V AC Step Down Transformer

Standard circuits are listed on the
following pages and 635.

Contactors

Illumination Circuit
	 99:	
	126:	
	246:	
	486:	

Relays & Sockets

Function

Contact Terminal Style
Blank:	 Standard	
N:	 Fingersafe	

Terminal Blocks

Lamp Type
Blank: Incandescent Lamp	
D: LED Lamp

Contact Arrangement
01: 1NC	
02: 2NC 	
04: 4NC	
22: 2NO-2NC

Circuit Breakers

10: 1NO	
	
20: 2NO	
	
40: 4NO	
	
11: 1NO-1NC	 	

1.	 Use only when interpreting part numbers. Do not use for developing part numbers.
2.	 All transformers step down to 6V (use 6V lamp).

800-262-IDEC (4332) • USA & Canada

631

Switches & Pilot Devices
Illuminated Selector Switches(Assembled) continued

Illuminated 2-Position Selector Switches

j Transformer Voltage Codes

Style

Part Number
Spring Return from Right

Spring Return from Left

Mounting

Maintained

Contact

Operator
Position

1NO
1NC

1
2

O
X

X
O

Transformer
Full Voltage

ASLW2 j 11m-k
ASLW29911m-k-l

ASLW21 j 11m-k
ASLW219911m-k-l

ASLW22 j 11m-k
ASLW229911m-k-l

2NO

1
2

O
O

X
X

Transformer
Full Voltage

ASLW2 j 20m-k
ASLW29920m-k-l

ASLW21 j 20m-k
ASLW219920m-k-l

ASLW22 j 20m-k
ASLW229920m-k-l

2NC

1
2

X
X

O
O

Transformer
Full Voltage

ASLW2 j 02m-104-k
ASLW29902m-104-k-l

ASLW21 j 02m-104-k
ASLW219902m-104-k-l

ASLW22 j 02m-104-k
ASLW229902m-104-k-l

2NO
2NC

1
2
3
4

O
X
O
X

X
O
X
O

Transformer
Full Voltage

ASLW2 j 22m-k
ASLW29922m-k-l

ASLW21 j 22m-k
ASLW219922m-k-l

ASLW22 j 22m-k
ASLW229922m-k-l

L

R

Lamp
Circuit Type

L

L

R

L

R

R

Style

Voltage

Code

120VAC

126

240VAC

246

480VAC

486

   	 Transformers step down to 6V
(use 6V lamp).

k LED/Lens Color Codes

Illuminated 3-Position Selector Switches, Maintained and Spring Return from Right

Color

Code

Amber

A

Green

G

Red

R

Blue

S

White

W

Yellow

Y

Part Number
Spring Return From Right

Spring Return from Left

Spring Return Two-Way

Mounting

Maintained

Contact

Operator Position

2NO

1
2

X
O

O
O

O
X

Transformer
Full Voltage

ASLW3 j 20m-k
ASLW39920m-k-l

ASLW31 j 20m-k
ASLW319920m-k-l

ASLW32 j 20m-k
ASLW329920m-k-l

ASLW33 j 20m-k
ASLW339920m-k-l

2NC

1
2

O
X

X
X

X
O

Transformer
Full Voltage

ASLW3 j 02m-k
ASLW39902m-k-l

ASLW31 j 02m-k
ASLW319902m-k-l

ASLW32 j 02m-k
ASLW329902m-k-l

ASLW33 j 02m-k
ASLW339902m-k-l

2NO
2NC

1
2
3
4

X
O
O
X

O
O
X
X

O
X
X
O

Transformer
Full Voltage

ASLW3 j 22m-k
ASLW39922m-k-l

ASLW31 j 22m-k
ASLW319922m-k-l

ASLW32 j 22m-k
ASLW329922m-k-l

ASLW33 j 22m-k
ASLW339922m-k-l

2NO
2NC

1
2
3
4

X
X
O
O

O
X
X
O

X
O
O
X

Transformer
Full Voltage

ASLW3 j 22m-309-k
ASLW39922m-309-k-l

ASLW31 j 22m-309-k
ASLW319922m-309-k-l

ASLW32 j 22m-309-k
ASLW329922m-309-k-l

ASLW33 j 22m-309-k
ASLW339922m-309-k-l

2NO
2NC

1
2
3
4

O
O
O
O

X
O
X
O

O
X
O
X

Transformer
Full Voltage

ASLW3 j 22m-310-k
ASLW39922m-310-k-l

ASLW31 j 22m-310-k
ASLW319922m-310-k-l

ASLW32 j 22m-310- k
ASLW329922m-310- k -l

ASLW33 j 22m-310-k
ASLW339922m-310-k-l

4NO

1
2
3
4

X
O
X
O

O
O
O
O

O
X
O
X

Transformer
Full Voltage

ASLW3 j 40m-k
ASLW39940m-k-l

ASLW31 j 40m-k
ASLW319940m-k-l

ASLW32 j 40m-k
ASLW329940m-k-l

ASLW33 j 40m-k
ASLW339940m-k-l

4NC

1
2
3
4

O
X
O
X

X
X
X
X

X
O
X
O

Transformer
Full Voltage

ASLW3 j 04m-k
ASLW39904m-k-l

ASLW31 j 04m-k
ASLW319904m-k-l

ASLW32 j 04m-k
ASLW329904m-k-l

ASLW33 j 04m-k
ASLW339904m-k-l

L

C

R

Lamp
Circuit Type

1.	 In place of j, specify the Transformer Voltage Code.
2.	 In place of  k, specify the Lens/LED Color Code.
3.	 In place of l, specify the Full Voltage Code.
4.	 In place of m specify Lamp Type Code
5.	 For custom contact configurations, see page 635.
6.	 Light is independent of switch position.
7.   Yellow selector switch comes with white LED.

Circuit Breakers

Terminal Blocks

Contactors

Timers

Relays & Sockets

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series

632 	

	

L

C

L

R

C

L

R

l Full Voltage Codes
Voltage

C

L

R

C

m Lamp Type Codes

Code

Lamp

Code

6V AC/DC

6V

Incandescent

Blank

12V AC/DC

12V

LED

D

24V AC/DC

24V

120V AC

120V (LED only)

240V AC

240V (LED only)

www.IDEC.com

R

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Illuminated Selector Switches (Sub-Assembled)
Transformer*

+

Contact Block

+

Operator

+ Lamp/Lead Holder† +

Lamp

+

Lens

=

Complete Part

Operators
Style

Lamps
Positions

Description

Part Number

Maintained

ASLW200

Spring return from right

ASLW2100

Spring return from left

ASLW2200

ASLW300-2

Spring return from left, cam 1
Spring return from left, cam 2

ASLW3200-1

Spring return from left/right, cam 1
Spring return from left/right, cam 2

ASLW3300-1

ASLW3100-2
ASLW3200-2
ASLW3300-2

Different cams produce different contact action. For details, see Contact Arrangements 	
on page 635.

Lenses (Knobs)

ASLWLU-k

Part Number

6V AC/DC

LSTD-6k

12V AC/DC

LSTD-1k

24V AC/DC

LSTD-2k

120V AC

LSTD-H2k

240V AC

LSTD-M4k

6V AC/DC

IS-6

12V AC/DC

IS-12

24V AC/DC

IS-24

1.	 In place of k, specify the LED color code.
2.	 The LED contains a current-limiting resistor and a
protection diode.

k LED/Lens Color Codes
Color

Code

Amber

A

Green

G

Red

R

Blue

S

White

W

Yellow

Y

	

Contactors

Part Number

Voltage

Timers

ASLW3100-1

Knob

Incandescent

ASLW300-3

Spring return from right, cam 1
Spring return from right, cam 2

Style

LED

ASLW300-1

Maintained, cam 1
Maintained, cam 2
Maintained, cam 3

3

Style

Relays & Sockets

2

	

Signaling Lights

*Full voltage units use a full voltage adaptor (TW-DA1B) instead of a transformer.
†
Lamp holder is not included with operators, order separately.
Lead holder is used when using 3 or more contact blocks. Order separately.

Yellow LED not available. Use
white LED

In place of k, specify the lens color code from table.

Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) • USA & Canada

633

Switches & Pilot Devices

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series

Illuminated Selector Switches (Sub-Assembled) continued
Contact Blocks
Style
Standard Exposed Screw

Fingersafe (IP20), CE marked

Transformers/Full Voltage Modules
Style

Part Number
1NO

1NC

HW-C10

HW-C01

HW-C10R
(early make)

HW-C01R
(late break)

HW-F10

HW-F01

HW-F10R
(early make)

HW-F01R
(late break)

Description

Full Size Transformer
Standard

Fingersafe

Part Number

120V AC

TW-T126B

240V AC

TW-T246B

480V AC

TW-T486B

120V AC

TW-F126B

240V AC

TW-F246B

480V AC

TW-F486B

Half Size Transformer
120V AC

TW-T126SB

240V AC

TW-T246SB

Standard

TW-DA1B

Fingersafe

TW-DA1FB

Standard

HW-DA1B

Fingersafe

HW-DA1FB

Dummy Block

Relays & Sockets

TW-DB

Full voltage model (use with
even number of contacts)

1.	 Dummy blocks (no contacts) are used with an odd number of contact blocks.
2.	 Use of early and late break contacts creates a make before break function

Lamp Circuit Components
Style

Application

Part Number

Short Lamp Holder
Timers

Used with a Half-size
Transformer and one
contact block

Contactors

Long Lamp Holder

Full voltage model (use with
odd number of contacts)

TW-LH1

Used with Full-size
Transformer and two
contact blocks
Used with Half-size
Transformer and three
contact blocks
Used with Full Voltage
Adaptor and two contact
blocks

TW-LH2

Used with TW-LH2
holder when using four
contact blocks

HW-LH3

All Transformers step down to 6V (use 6V lamp).

Circuit Breakers

Terminal Blocks

Lead Holder

634 	

	

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series

L

How to Read Contact Arrangement Charts
To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right

Contact Arrangement

Circuit Number

Type and quantity of switch
contacts

* N/D = No designation
required

1

Contact Block
Mounting Position

Operator Position
Truth table indicates the operating position of contact block
when operator is switched to
that position.

Position or mounting 	
contact blocks on operator

N/D

1NC

116

1NO
1NC
103

600
1NO-EM
1NC-LB

2NO

N/D

2NC

104

2NO
2NC

R

1

O

X

HW-C10

2

O

O

TW-DB

1

X

O

HW-C01

2

O

O

TW-DB

1

O

X

HW-C10

2

X

O

HW-C01

1

X

O

HW-C01

2

O

X

HW-C10

1

O

X

HW-C10R

2

X

O

HW-C01R

1

X

O

HW-C01R

2

O

X

HW-C10R

1

O

X

HW-C10

2

O

X

HW-C10

1

X

O

HW-C01

2

X

O

HW-C01

1

O

X

HW-C10

2

X

O

HW-C01

3

O

X

HW-C10

4

X

O

HW-C01

1

O

X

HW-C10

2

O

X

HW-C10

3

X

O

HW-C01

4

X

O

HW-C01

L

R

Spring Ret.
from Rt.
L

R

Spring Ret.
from Lt.
L

Knob/Lever
Key
Illuminated Knob

ASW200
ASW2K00
ASLW200

ASW2100
ASW21K00
ASLW2100

ASW2200
ASW22K00
ASLW2200

Knob/Lever
Key
Illuminated Knob

ASW200
ASW2K00
ASLW200

ASW2100
ASW21K00
ASLW2100

ASW2200
ASW22K00
ASLW2200

Knob/Lever
Key
Illuminated Knob

ASW200
ASW2K00
ASLW200

ASW2100
ASW21K00
ASLW2100

ASW2200
ASW22K00
ASLW2200

Knob/Lever
Key
Illuminated Knob

ASW200
ASW2K00
ASLW200

ASW2100
ASW21K00
ASLW2100

ASW2200
ASW22K00
ASLW2200

Knob/Lever
Key
Illuminated Knob

ASW200
ASW2K00
ASLW200

ASW2100
ASW21K00
ASLW2100

ASW2200
ASW22K00
ASLW2200

Knob/Lever
Key
Illuminated Knob

ASW200
ASW2K00
ASLW200

ASW2100
ASW21K00
ASLW2100

ASW2200
ASW22K00
ASLW2200

Knob/Lever
Key
Illuminated Knob

ASW200
ASW2K00
ASLW200

ASW2100
ASW21K00
ASLW2100

ASW2200
ASW22K00
ASLW2200

Knob/Lever
Key
Illuminated Knob

ASW200
ASW2K00
ASLW200

ASW2100
ASW21K00
ASLW2100

ASW2200
ASW22K00
ASLW2200

Knob/Lever
Key
Illuminated Knob

ASW200
ASW2K00
ASLW200

ASW2100
ASW21K00
ASLW2100

ASW2200
ASW22K00
ASLW2200

Knob/Lever
Key
Illuminated Knob

ASW200
ASW2K00
ASLW200

ASW2100
ASW21K00
ASLW2100

ASW2200
ASW22K00
ASLW2200

R

Circuit Breakers

111

L

Maintained

Description

Terminal Blocks

N/D

Contact Block
Part Number

Contactors

601

Operator Part Number

Timers

N/D

Part number to use when
ordering sub-assembly contact
blocks, as required for use
with corresponding mounting
position

Relays & Sockets

1NO

Mounting
Position

Contact Block
Part Number

Signaling Lights

Contact

Circuit
Number

Operator
Position

2

3

Contact Arrangement Chart: 2-Position Selector Switches
Style

4

R

Switches & Pilot Devices

Contact Arrangement Charts

1.	 NO-EM, NC-LB = Early Make, Late Break.	
N/D = No circuit number designation required in assembled selector switch part number.
2.	 X = On (closed contacts) O = Off (Open contacts)

800-262-IDEC (4332) • USA & Canada

635

Switches & Pilot Devices

Switches & Pilot Devices

ø22mm - TW Series
Contact Arrangement Chart: 3-Position Selector Switches
Style

Operator Part Number
Operator Position

Contact

Circuit
Number

Signaling Lights

202

203
1NO
1NC
302

Relays & Sockets

303

N/D
2NO
301

Timers

304
2NC
N/D

Contactors

N/D

210

2NO
2NC
Terminal Blocks

308

309

Circuit Breakers

310

Mounting
Position

Contact Block
Part Number

L

C

1

X

0

0

HW-C10

2

X

X

O

HW-C01

1

0

X

X

HW-C01

2

O

0

X

HW-C10

1

X

0

X

HW-C10

2

X

X

O

HW-C01

1

0

X

O

HW-C01

2

O

0

X

HW-C10

1

X

0

0

HW-C10

2

O

0

X

HW-C10

1

X

0

X

HW-C10

2

O

0

X

HW-C10

1

0

X

O

HW-C01

2

X

X

O

HW-C01

1

0

X

X

HW-C01

2

X

X

O

HW-C01

1

X

0

0

HW-C10

2

0

0

X

HW-C10

3

0

X

X

HW-C01

4

X

X

0

HW-C01

1

0

X

X

HW-C01

2

0

0

X

HW-C10

3

0

X

X

HW-C01

4

0

0

X

HW-C10

R

Description

Maintained
L

1

X

0

X

HW-C10

2

X

X

0

HW-C01

3

X

0

X

HW-C10

4

X

X

O

HW-C01

1

X

0

X

HW-C10

2

X

X

0

HW-C01

3

0

X

O

HW-C01

4

O

0

X

HW-C10

1

0

X

O

HW-C01

2

O

0

X

HW-C10

3

0

X

O

HW-C01

4

0

0

X

HW-C10

C

R

Spring Return
from Right
L

C

R

Spring Return
from Left
L

C

R

Two-Way
L

C

R

Knob/Lever
Key
Illuminated Knob

ASW300-1
ASW3K00-1
ASLW300-1

ASW3100-1
ASW31K00-1
ASLW3100-1

ASW3200-1
ASW32K00-1
ASLW3200-1

ASW3300-1
ASW33K00-1
ASLW3300-1

Knob/Lever
Key
Illuminated Knob

ASW300-1
ASW3K00-1
ASLW300-1

ASW3100-1
ASW31K00-1
ASLW3100-1

ASW3200-1
ASW32K00-1
ASLW3200-1

ASW3300-1
ASW33K00-1
ASLW3300-1

Knob/Lever
Key
Illuminated Knob

ASW300-2
ASW3K00-2
ASLW300-2

ASW3100-2
ASW31K00-2
ASLW3100-2

ASW3200-2
ASW32K00-2
ASLW3200-2

ASW3300-2
ASW33K00-2
ASLW3300-2

Knob/Lever
Key
Illuminated Knob

ASW300-2
ASW3K00-2
ASLW300-2

ASW3100-2
ASW31K00-2
ASLW3100-2

ASW3200-2
ASW32K00-2
ASLW3200-2

ASW3300-2
ASW33K00-2
ASLW3300-2

Knob/Lever
Key
Illuminated Knob

ASW300-1
ASW3K00-1
ASLW300-1

ASW3100-1
ASW31K00-1
ASLW3100-1

ASW3200-1
ASW32K00-1
ASLW3200-1

ASW3300-1
ASW33K00-1
ASLW3300-1

Knob/Lever
Key
Illuminated Knob

ASW300-2
ASW3K00-2
ASLW300-2

ASW3100-2
ASW31K00-2
ASLW3100-2

ASW3200-2
ASW32K00-2
ASLW3200-2

ASW3300-2
ASW33K00-2
ASLW3300-2

Knob/Lever
Key
Illuminated Knob

ASW300-2
ASW3K00-2
ASLW300-2

ASW3100-2
ASW31K00-2
ASLW3100-2

ASW3200-2
ASW32K00-2
ASLW3200-2

ASW3300-2
ASW33K00-2
ASLW3300-2

Knob/Lever
Key
Illuminated Knob

ASW300-1
ASW3K00-1
ASLW300-1

ASW3100-1
ASW31K00-1
ASLW3100-1

ASW3200-1
ASW32K00-1
ASLW3200-1

ASW3300-1
ASW33K00-1
ASLW3300-1

Knob/Lever
Key
Illuminated Knob

ASW300-1
ASW3K00-1
ASLW300-1

ASW3100-1
ASW31K00-1
ASLW3100-1

ASW3200-1
ASW32K00-1
ASLW3200-1

ASW3300-1
ASW33K00-1
ASLW3300-1

Knob/Lever
Key
Illuminated Knob

ASW300-1
ASW3K00-1
ASLW300-1

ASW3100-1
ASW31K00-1
ASLW3100-1

ASW3200-1
ASW32K00-1
ASLW3200-1

ASW3300-1
ASW33K00-1
ASLW3300-1

Knob/Lever
Key
Illuminated Knob

ASW300-2
ASW3K00-2
ASLW300-2

ASW3100-2
ASW31K00-2
ASLW3100-2

ASW3200-2
ASW32K00-2
ASLW3200-2

ASW3300-2
ASW33K00-2
ASLW3300-2

Knob/Lever
Key
Illuminated Knob

ASW300-2
ASW3K00-2
ASLW300-2

ASW3100-2
ASW31K00-2
ASLW3100-2

ASW3200-2
ASW32K00-2
ASLW3200-2

ASW3300-2
ASW33K00-2
ASLW3300-2

Knob/Lever
Key
Illuminated Knob

ASW300-2
ASW3K00-2
ASLW300-2

ASW3100-2
ASW31K00-2
ASLW3100-2

ASW3200-2
ASW32K00-2
ASLW3200-2

ASW3300-2
ASW33K00-2
ASLW3300-2

1.	 Each operator sub-assembly is available as a “-1” and a “-2” for 3-position selector switches. The internal cam of a “-1” is different from that of a “-2”. This results in designated combinations of open
and closed contacts in the various operator positions.
2.	 N/D = No circuit number designation required in assembled part number.
3.	 X = On (closed contacts) O = Off (open contacts). X   X   Overlapping contacts remain on (closed) when switch is moved between these two positions.

636 	

	

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Contact Arrangement Chart: 3-Position Selector Switches
Style

Operator Part Number
Operator Position

Contact

Circuit
Number

4NO
305

4NC
314

C

R

Description

Maintained
L

1

X

0

0

HW-C10

2

0

0

X

HW-C10

3

X

0

0

HW-C10

4

0

0

X

HW-C10

1

X

0

X

HW-C10

2

0

0

X

HW-C10

3

X

0

X

HW-C10

4

0

0

X

HW-C10

1

0

X

X

HW-C01

2

X

X

0

HW-C01

3

0

X

X

HW-C01

4

X

X

O

HW-C01

1

0

X

O

HW-C01

2

X

X

0

HW-C01

3

0

X

O

HW-C01

4

X

X

0

HW-C01

C

R

L

C

R

Spring Return
from Left
L

C

R

Two-Way
L

C

R

Knob/Lever
Key
Illuminated Knob

ASW300-1
ASW3K00-1
ASLW300-1

ASW3100-1
ASW31K00-1
ASLW3100-1

ASW3200-1
ASW32K00-1
ASLW3200-1

ASW3300-1
ASW33K00-1
ASLW3300-1

Knob/Lever
Key
Illuminated Knob

ASW300-2
ASW3K00-2
ASLW300-2

ASW3100-2
ASW31K00-2
ASLW3100-2

ASW3200-2
ASW32K00-2
ASLW3200-2

ASW3300-2
ASW33K00-2
ASLW3300-2

Knob/Lever
Key
Illuminated Knob

ASW300-1
ASW3K00-1
ASLW300-1

ASW3100-1
ASW31K00-1
ASLW3100-1

ASW3200-1
ASW32K00-1
ASLW3200-1

ASW3300-1
ASW33K00-1
ASLW3300-1

Knob/Lever
Key
Illuminated Knob

ASW300-2
ASW3K00-2
ASLW300-2

ASW3100-2
ASW31K00-2
ASLW3100-2

ASW3200-2
ASW32K00-2
ASLW3200-2

ASW3300-2
ASW33K00-2
ASLW3300-2

Relays & Sockets

N/D

L

Contact Block
Part Number

Signaling Lights

N/D

Mounting
Position

Spring Return
from Right

Timers

1.	 Each operator sub-assembly is available as a “-1” and a “-2” for 3-position selector switches. The internal cam of a “-1” is different from that of a “-2”. This results in designated combinations of open
and closed contacts in the various operator positions.
2.	 N/D = No circuit number designation required in assembled part number.
3.	 X = On (closed contacts) O = Off (open contacts). X   X   Overlapping contacts remain on (closed) when switch is moved between these two positions.

Contactors
Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) • USA & Canada

637

Switches & Pilot Devices

Switches & Pilot Devices

ø22mm - TW Series

Custom Selector Switch Building Guide
To build a custom selector switch, follow these steps.

Mounting Positions

Step 1

L

4

2

How many positions of the switch are needed?
# of positions
(2, 3, 4, 5)

Signaling Lights

R

3
1

Step 2
How many contacts should there be?

Relays & Sockets

# of isolated contacts
(maximum 6)

Step 3
Fill in the Truth Table
(X = closed, 0 = open)
Knob Position
1

2

3

4

5

1
Contacts

Timers

2
3
4
5
6

Contactors

Step 4
If building a 2 position selector, skip this step. (2 position selectors have only one cam)
If building a 3, 4, or 5 position selector, determine appropriate cam as follows:
•	 Look at Row 1 from above table and locate an identical row in the operator truth tables (See next page).
•	 Repeat for all rows. The user must find one operator that contains all rows from above table.
•	 Record the operator cam version.

Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. “L” and “R” refer to mounting on left or right
side of operator as viewed from the front of the panel.

Step 6
Develop an assembly part number (if necessary) as follows: follow standard numbering nomenclature for selector switches (see pages 627 or 631. In place of the
“Circuit Number” indicate the cam number and contact arrangement as such ASW322-3-OELCSS, where “3” is the cam number, and contact arrangement “OELCXX”
calls out individual contact mounting locations in order (see diagram above). O=NO, C=NC, E=NO-EM, L=NC-LB, X= no contact. Part number must designate all 6 possible mounting locations.

Circuit Breakers

Terminal Blocks

Step 5

Caution: Before putting any custom selector switch into use, the user should use an ohmmeter to test for desired performance.
1.	 For Operator Truth Tables, see next page.

638 	

	

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Operator Truth Tables
Use the following tables to build custom selector switches.

4 Position Selector Switches

2 Position Selector Switches
Contact

ASW200
ASLW200
ASW2K00

HW-C01
(NC)
HW-C10R
(NO-EM)
HW-C01R
(NC-LB)

Operator
Position
Left

Right

L

O

X

R

O

X

L

X

O

R

X

O

L

O

X

R

O

X

L

X

O

R

X

O

Contact

Contact
HW-C10
(NO)
ASW300-1
ASW3K00-1
ASLW300-1

HW-C01
(NC)

HW-C01R
(NC-LB)

Contact

ASW300-2
ASW3K00-2
ASLW300-2

HW-C01
(NC)
HW-C10R
(NO-EM)
HW-C01R
(NC-LB)

HW-C10
(NO)

HW-C10R
(NO-EM)
HW-C01R
(NC-LB)

O

O

X

O

O

HW-C01
(NC)

L

O

X

X

X

R

X

O

X

X

HW-C10R
(NO-EM)

L

X

O

O

O

R

O

X

O

O

HW-C01R
(NC-LB)

L

O

X

X

X

R

X

O

X

X

Mounting
Position

1

Center

Right

L

X

O

O

R

O

O

X

L

O

X

X

R

X

X

O

L

X

O

O

R

O

O

X

L

O

X

X

R

X

X

O

ASW400-1

Left

Center

Right

L

X

O

X

R

O

O

X

L

O

X

O

R

X

X

O

L

X

O

X

R

O

O

X

L

O

X

O

R

X

X

O

Left

Center

Right

L

X

O

O

R

O

O

X

L

O

X

O

R

O

X

O

L

X

O

X

R

X

O

X

L

O

X

X

R

X

X

O

3

4

L

X

O

O

O

R

O

O

O

X

HW-C01
(NC)

L

O

O

X

O

R

O

X

O

O

L

X

X

O

X

R

X

O

X

X

L

O

X

X

X

R

X

X

X

O

HW-C10R
(NO-EM)

5 Position Selector Switches
Contact
HW-C10
(NO)

ASW500

HW-C01
(NC)
HW-C10R
(NO-EM)
HW-C01R
(NC-LB)

Contact

Operator Position

Mounting
Position

2

HW-C10
(NO)

HW-C01R
(NC-LB)

Operator Position

Mounting
Position

Operator Position

HW-C10
(NO)

ASW500-1

800-262-IDEC (4332) • USA & Canada

HW-C01
(NC)
HW-C10R
(NO-EM)
HW-C01R
(NC-LB)

Operator Position

Mounting
Position

1

2

3

4

5

L

X

O

O

O

O

R

O

X

O

O

O

L

O

O

X

X

X

R

O

O

O

X

X

L

X

O

O

O

O

R

O

X

O

O

O

L

O

X

X

X

X

R

X

O

X

X

X

Operator Position

Mounting
Position

1

2

3

4

5

L

X

O

O

O

O

R

O

O

O

O

X

L

O

O

O

X

O

R

O

X

O

O

O

L

X

X

X

O

X

R

X

O

X

X

X

L

O

X

X

X

X

R

X

X

X

X

O

Circuit Breakers

ASW300-3
ASW3K00-3
ASLW300-3

HW-C01
(NC)

O

Terminal Blocks

Contact

X
O

Contactors

HW-C10
(NO)

Left

4

Timers

HW-C10R
(NO-EM)

Operator Position

3

L

Contact

Mounting
Position

2

Relays & Sockets

3 Position Selector Switches

Operator Position
1

R

HW-C10
(NO)

ASW400

Mounting
Position

Signaling Lights

HW-C10
(NO)

Mounting
Position

639

Switches & Pilot Devices
Nameplates — TW Series

Faceplates
NWAL

NWAQL
1.13" (29mm)

ø70mm

0.566"

(14.5mm)

1.76" (45mm)

0.975"

(25mm)

1.0"

Signaling Lights
Relays & Sockets
Timers

1.76" (45mm)

Part Number
NWAL-OB (black)
NWAL-OR (red)

NWAQL-OB (black)
NWAQL-OR (red)

NWAS-OB

NWAR-O

Nameplate
(engraved)

NWAL-j

NWAQL-j

NWAS-j

NWAR-27†

1.	 In place of  j, insert either the Standard Legend Code from table below or custom engraving delimited by “ “.
2.	 Standard engravings are available at no charge.
3	 NWAR-27 comes marked “Emergency Stop” as shown in drawing.

Standard Legend Codes
Legend
AUTO
CLOSE
DOWN
EMERG.STOP
FAST
FORWARD
HAND
HIGH
IN
INCH
JOG
LOW
LOWER
OFF
ON

Code
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115

Legend
OPEN
OUT
RAISE
RESET
REVERSE
RUN
SLOW
START
STOP
STOP
TEST
UP
I (Int’l On)
O (Int’l Off)
EMO

Pushbuttons/Selector Switches
Code
116
117
118
119
120
121
122
123
124
125
126
127
150
151
152

Legend
AUTO-MAN
CLOSE-OPEN
DOWN-UP
FAST-SLOW
FOR-REV
HAND-AUTO
HIGH-LOW
JOG-RUN
LEFT-RIGHT
LOWER-RAISE
MAN-AUTO
OFF-ON
ON-OFF
OPEN-CLOSE
RAISE-LOWER

Code
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215

Legend

REV-FOR
RUN-JOG
RUN-SAFE
SAFE-RUN
SLOW-FAST
START-STOP
STOP-START
UP-DOWN

Selector Switches
Code

Legend

Code

216
217
218
219
220
221
222
223

AUTO-MAN-OFF
AUTO-OFF-MAN
CLOSE-OFF-OPEN
DOWN-OFF-SLOW
FAST-OFF-SLOW
FOR-OFF-REV
LEFT-OFF-RIGHT
LOWER-OFF-RAISE
OFF-MAN-AUTO
OFF-SLOW-FAST
OFF-1-2
OPEN-OFF-CLOSE
SLOW-OFF-FAST
SUMMER-OFF-WINTER
UP-OFF-DOWN
1-OFF-2
HAND-OFF-AUTO

301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317

1. 	 To order engraved nameplates, add legend code to nameplate part number.
	 Character height based on the number of characters and size of nameplate. Standard character size is 3/16”.
2. 	 Nameplates with standard legends are the same list price as blank nameplates.

Nameplate Order Form on next page.

Circuit Breakers

Terminal Blocks

EMERGENCY STOP

Nameplate
(blank)

Pushbuttons

Contactors

NWAS

1.13" (29mm)
(25.4mm)

Switches & Pilot Devices

ø22mm - TW Series

640 	

	

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series

Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. 	
To ensure engraving accuracy, fax it to your IDEC representative. or Distributor.	
	

IDEC Rep/Distributor Contact:__________________________________

	

Your Name:_ _________________________________________

	

PO number (if known):__________________________________

	

Telephone:_ _________________________________________

	

IDEC Rep/Distributor Phone:__________________________________

	

Fax & Email:_ _________________________________________

NWAL

Step 1.

Choose Letter Size - 7/64” or 1/8”.

7/64” Letters:
1/8” Letters:

Qty

1

8 9 10 11

7/64”

11 characters max 	
(for 7/64” size letters)

1/8”

9 characters max 	
(for 1/8” size letters)

Letter Size

Qty

1

Choose Letter Size - 1/8” or
3/32”.

3

4 5

8 9 10 11

20 characters max 	
(for 3/32” size letters)

1/8”

14 characters max 	
(for 1/8” size letters)

Letter Size

1

2

3

4

5

6

7

8 9 10 11 12 13 14 15 16 17 18 19 20
Circuit Breakers

Enter the location of 	
engraving (A or B), in 	
the box on the right.

7

3/32”

Letter Size

Specify Location.	

6

Terminal Blocks

Check the box for the letter
size you want. Then write
your lettering in box below
checkboxes. Note: 1/8” size
letters cannot exceed 14
characters.

2

Contactors

1/8” Letters:

Step 3.

Qty

7

7/64” Letters:

Engraving Location B

Enter the number of 	
nameplates desired 	
in the box on the right.

6

   

Step 1.

   

4 5

Sample Letter Sizes

Enter the number of 	
nameplates desired 	
in the box on the right.

Specify Quantity.	

3

Letter Size

Check the box for the letter size you
want. Then write your lettering in box
below checkboxes. Note: 1/8” size
letters cannot exceed 9 characters.

Engraving Location A

2

Timers

Choose Letter Size - 7/64” or 1/8”.

Specify Quantity.	

Step 2.

Letter Size

Step 1.

NWAS

9 characters max 	
(for 1/8” size letters)

   

Enter the number of 	
nameplates desired 	
in the box on the right.

Step 2.

1/8”

Relays & Sockets

Specify Quantity.	

Engraving
Location

11 characters max 	
(for 7/64” size letters)

Sample Letter Sizes

Step 2.

NWAQL

7/64”

Letter Size

Check the box for the letter size you
want. Then write your lettering in box
below checkboxes. Note: 1/8” size
letters cannot exceed 9 characters.

Engraving
Location

	IDEC Rep/Distributor Fax & Email:__________________________________

Signaling Lights

	 Your Company Name:_ _________________________________________

Switches & Pilot Devices

Custom Engraved Nameplates Order Form — TW Series

Sample Letter Sizes

   

3/32” Letters:

Location

800-262-IDEC (4332) • USA & Canada

1/8” Letters:

641

Switches & Pilot Devices

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series

Switch Engraving Order Form – TW Series
Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved.
To ensure engraving accuracy, fax it to your IDEC representative or Distributor.

Your Company:

Telephone:

Name:

Fax:

Address:

Email:

PO:

Part Number to be Engraved:

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

Please check one of the boxes below to indicate your choice of engraving options:
Relays & Sockets

ø29mm, ø40mm Mushroom Head
Engraving
Area 1
Area 2†

# of Lines

Letter
Height

Max. Characters
Per Line

5/32

# of
Lines

6        

Timers

Letter
Height

Max. Characters
Per Line

5/32

1

5        

1
   1/8  

6        

5/32

6        

2

   1/8  

6        

5/32

5        

2
5        

3

1/8

6        

4

3/32

5        

Contactors

1/8

1/8

6        

3

1/8

5        

4

3/32

5        

	

	

	

	

	

	

Engraving
Area 1

1

Engraving
Area 2

1

5/32 Letters:

Line 2:
Line 3:

For IDEC Internal Use Only:
Work Order #:

642 	

	

Sample Letter Sizes
1/8 Letters:

Line 1:

Line 4:

Circuit Breakers

# of
Lines

1.	 Above mentioned specifications hold true for standard size pushbuttons (round and square).
2. 	 †Engraving Area 2 can be engraved for 40mm mushroom Head non-Illuminated push button only.
3.	 Engraving is done on the button itself for non-Illuminated push buttons and on marking plate for illuminated push buttons and pilot lights.
4.	 Please enter text exactly how you want it engraved, take care to emphasize capital or small letters.

Enter text to be engraved:	
	
Terminal Blocks

Engraving

Round
Switch

Square
Switch

www.IDEC.com

Letter
Height

Max. Characters
Per Line

5/32

5

1/8

5

5/32

7

1/8

7

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Accessories
TW Series Accessories
Item

Appearance

Description/Usage

Part Number

Contact Block Remover

Used to remove contact blocks, transformers, lenses, and adaptors. Can also be used to 	
determine panel thickness adjustment.

TW-KC1

Nut Locking Wrench

Used in OR-14 locking wrench to tighten locking nuts inside square bezel

TW-KQ2

Metal Bezel

Chrome plated bezels 	
tighten onto operator
(replacement for 	
damaged bezels)

Plastic Bezel

Black plastic bezels for
square buttons
(replacement for 	
damaged bezels)

Standard octagonal units (chrome-pl.)

AW-R8

Full shroud octagonal units (chrome-pl.)

AW-RF8

Full shroud mushroom head units Ø 40mm

AW-G4

Round flush units (black plastic)

AW-RP1B

Round extended units (black plastic)

AW-FP1B

Square units (black plastic)

AW-Q1B

Square units with full shroud (black plastic)

AW-QF1B

Waterproof lens cover for square pilot lights

APW00LN

Waterproof lens cover for square illuminated buttons
Boot/Cover

APW00L

Clear boot for round flush units

OC-31

Clear boot for round extended units

OC-32

*In place of asterisk, specify Rubber Boot color:
B (black), G (green), R (red), Y (yellow) - (nitril rubber)

OCW-11*

Ring to prevent operator base from rotating in the mounting hole.
Used when nameplate is not used

OGL-31

Mounting Hole Plug

Black rubber plug fills unused mounting holes in panel.

OB-31

Metallic Mounting Hole
Plug

For plugging unused mounting holes in the panel. Tighten the attached locking ring to a torque of
12 kfg-cm maximum
Degree of protection: IP66

Replacement Keys

Pair of keys (#0)

LW9Z-BM

Terminal Blocks

TW-SK

AKW2B-B

Used on flush buttons to prevent inadvertent actuation

800-262-IDEC (4332) • USA & Canada

Circuit Breakers

Metal Button Guard

Contactors

Anti-Rotation Ring

Replacement Black
Sleeve for Keyswitch

Timers

Used to cover and protect
pushbuttons

OR-55

Relays & Sockets

Rubber tool used to install or remove LED’s and incandescent lamps

Signaling Lights

Lamp Removal Tool

OLW-C

643

Switches & Pilot Devices

Relays & Sockets

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series
Item

Appearance

Description/Usage

Part Number

Terminal Tab Adaptor

Quick- connect terminals

#250 (17/64” x 3/64”) single tab

TW-FA1

Lock-out Adaptor

Used to provide lock-out protection for pushbuttons and knob selector switches:
• Up to Ø 40mm mushroom head size
(Padlock not included.)
Not applicable for e-stops.

HW9Z-KL1

TW to TWTD Adaptor

Used to mount TW series control unit (except square units) Ø 7/8” (22mm) into a Ø 1-13/64”
(30mm) panel cut-out.

TWN-A1R8

Replacement Marking
Plates

White plastic engraving plate
for use on all illuminated units
(included in each lens).
May be used to capture
printed mylar insert (not supplied by IDEC) under lens face.

Round Pushbutton (Ø14mm)

ALW2B

Round Pilot Light (Ø 14mm)

APW2B

Mushroom Pushbutton (Ø 14mm)

ALW3B

Square Pilot Light (q 21mm)

APQW1B

Square Pushbutton (q 21mm)

ALQW2B

Fingersafe Covers for TW Series
Description

Used with

644 	

	

Part Number

Fingersafe terminal cover, adds 6mm to overall depth

APW and UPQW full voltage pilot lights

APS-PVL

Fingersafe terminal cover, adds 3.5mm to overall
depth. One required for each contact, only for rearmost terminals

Non-illuminated pushbuttons and selectors

HW-VL2

Fingersafe terminal cover, adds 3mm to overall depth

APW and UPQW transformer pilot lights, and illuminated pushbuttons and illuminated selectors

HW-VL3

Fingersafe terminal cover for contacts.

Full voltage illuminated pushbuttons and selectors

HW-VL4

Fingersafe terminal cover for full voltage adaptor, adds
3 mm to depth

Full voltage illuminated pushbuttons and selectors

HW-VL5

Fingersafe terminal cover for half size transformer
adaptor, adds 3 mm to depth

Illuminated pushbuttons and selectors

HW-VL6

Circuit Breakers

Terminal Blocks

Contactors

Timers

Appearance

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Dimensions
Pushbuttons

37
30

30

47

M3.5 Terminal
Screws

68.5 (3-4 blocks)

37

37
30

47

Panel Thickness
1 to 6

37

ø40

48.5 (1-2 blocks)

25

25

Square Flush

Panel Thickness
1 to 6

37

ø40

M3.5 Terminal
Screws

45°

13

68.5 (3-4 blocks)

40mm Push-Pull
Reset
(unlock)

13

68.5 (3-4 blocks)

48.5 (1-2 blocks)

22.5

45°

37

68.5 (3-4 blocks)

Panel Thickness Reset
1 to 6
(unlock)

Timers

48.5 (1-2 blocks)

M3.5 Terminal
Screws

Reset Angle 75°

ø40

37

ø29

Panel Thickness
1 to 6

Keylock Push On/Off

48.5 (1-2 blocks) 13

30

22.5

40mm Pushlock Key reset
M3.5 Terminal
Screws

Panel Thickness
1 to 6

ø29

M3.5 Terminal
Screws

30

23

37

40mm Push-Lock-Turn-Reset

Reset Angle 75°

48.5 (1-2 blocks) 13
68.5 (3-4 blocks)

68.5 (3-4 blocks)

Relays & Sockets

Panel Thickness
1 to 6

48.5 (1-2 blocks)

30

22.5

25

68.5 (3-4 blocks)

30

Panel Thickness 1 to 6

37

37

22.5

M3.5 Terminal
Screw

Panel Thickness 1 to 6

48.5 (1-2 blocks) 13

13

29mm Push-Lock-Turn-Reset
M3.5 Terminal
Screws

Mushroom with Full Shroud

ø40

Panel Thickness 1 to 6

ø29
48.5 (1-2 block)

ø24

40mm Mushroom
M3.5 Terminal
Screws

30

ø46

29mm Mushroom

48.5 (1-2 blocks) 19.5
68.5 (3-4 blocks)

30

19

30

68.5 (3-4 blocks)

Signaling Lights

30

Panel Thickness 1 to 6

37

ø24

48.5 (1-2 blocks) 13

48.5 (1-2 blocks) 13

68.5 (3-4 blocks)

M3.5 Terminal
Screws

Panel Thickness 1 to 6

37

ø29

ø24

Panel Thickness 1 to 6

68.5 (3-4 blocks)

M3.5 Terminal
Screws

Extended with Full Shroud

M3.5 Terminal
Screws

ø29

Extended

M3.5 Terminal
Screws

ø29

Flush

13
25

48.5 (1-2 blocks) 13
30

30.5

30

68.5 (3-4 blocks)

Square Extended

37

Contactors

30

Panel Thickness
1 to 6

25

M3.5 Terminal
Screws

48.5 (1-2 blocks) 13
68.5 (3-4 blocks)

30

20

Selector Switches

48.5 (2 blocks)

13
25

30

68.5 (4 blocks)

13
25

30

48.5 (2 blocks)
68.5 (4 blocks)

37

ø29

ø24

37

37

ø25
48.5 (2 blocks)
68.5 (4 blocks)

Panel Thickness 1 to 6

Terminal Blocks

ø29

M3.5 Teminal
Screws

Panel Thickness 1 to 6

ø29

M3.5 Terminal
Screws

Panel Thickness 1 to 6

ø24

M3.5 Terminal
Screws

13
19
41

30

Circuit Breakers

800-262-IDEC (4332) • USA & Canada

645

Switches & Pilot Devices
Dimensions continued

Illuminated Pushbuttons
Extended with Full Shroud

25

37

ø29

ø24

37

ø29

30

Panel Thickness
1 to 6

Reset Angle: 75°

13

30

22.5

13
30

22.5

Marking plate: ø13.9mm

21mm

Panel Thickness
1 to 6

Reset Angle 75°

ø40

37

13

Marking plate:

Mushroom

37

Panel Thickness
1 to 6

40mm Push-Turn-Reset

ø29

Marking plate: ø15.5mm

29mm Push-Turn-Reset

30

20

Marking plate: ø15.5mm

37

20

30

19

ø29

Signaling Lights

Panel Thickness
1 to 6

13

13

30

22.5
Marking plate: ø13.9mm

Marking plate: ø13.9mm

Push-Pull
Panel Thickness
1 to 6

37

ø40

Relays & Sockets

Square Extended

Panel Thickness
1 to 6

37

Panel Thickness
1 to 6

30

Extended

ø24

Switches & Pilot Devices

ø22mm - TW Series

13
25

30

30.5

Illuminated Selector Switches
1 Contact Block with Full Voltage Adaptor

Transformer (2 blocks)
X1

X1

Timers

Marking plate: ø13.9mm

M3.5 Terminal Screws

1 Contact Block with Half Size Transformer
Panel Thickness
1 to 6

X2

Panel Thickness
1 to 6

X1

X2

X2

Contactors

86.5

64.5

2 Contact Blocks with Full Voltage Adaptor Transformer (4 blocks)
M3.5
Terminal Screw

X1

Panel Thickness
1 to 6mm

M3.5 Terminal Screws

2 Contact Blocks with Half Size Transformer
Panel Thickness
1 to 6

X2

Panel Thickness
1 to 6

X1
X2

106.5

63.5

68.5

3 Contact Blocks with Full Voltage Adaptor 4 Contact Blocks with Full Voltage Adaptor 3 Contact Blocks with Half Size Transformer
M3.5
Terminal Screws

Panel Thickness
1 to 6

Panel Thickness
1 to 6

X1
X2

X2

X1

Terminal Blocks

X2

X1

X1

Circuit Breakers

X2

68.5

M3.5 Terminal Screws

84.5

646 	

	

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Dimensions continued
Pilot Lights
Round Flush APW1 Transformer

28.5

30

Marking plate: ø15.5 mm

28.5
66.5

25

37

30

37
37

Panel Thickness 1 to 6

28.5
66.5

22 mm

Timers

25

Square Flush Marking Type APQW1B Transformer

30
Marking plate:

30

25

M3.5 Terminal
Screw

Panel Thickness
1 to 6

13

13
16

37

Square Flush Marking Type APQW1B Full Voltage

ø29

ø23.6

37
30

25

13

Marking plate: ø15.5 mm

Panel Thickness
1 to 6

M3.5 Terminal
Screw

ø29

ø23.6
13

30

17

Dome APW2 Transformer

Panel Thickness
1 to 6

16

13

Relays & Sockets

66.5

ø29

ø24
28.5

30

Dome APW2 Full Voltage

28.5

Panel Thickness
1 to 6

37

13
17

28.5

Round Flush Marking Type APW1B Transformer
M3.5 Terminal
Screw

ø29

ø24

Panel Thickness
1 to 6

30

17

Signaling Lights

Round Flush Marking Type APW1B Full Voltage

28.5

13

66.5

17

37

ø24

37

13

30

28.5

Panel Thickness
1 to 6

M3.5 Terminal Screw

ø29

ø24

Panel Thickness
1 to 6

ø29

Round Flush APW1 Full Voltage

30
Marking plate:

22 mm

A: 63.5 (2 blocks)
83.5 (4 blocks)

37

ø29

Panel Thickness 1 to 6

ø24

M3.5 Terminal Screws

Contactors

Illuminated Selector Switches

13
25

30

B: 86.5 (2 blocks), 106.5 (4 blocks)

Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) • USA & Canada

647

Switches & Pilot Devices

Switches & Pilot Devices

ø22mm - TW Series

Dimensions continued

Panel Cut-Out
Diagram

Dimension

Part

A

A

B

C

D

Pushbuttons

1.17” (30mm)
Std. Octagonal

Pilot Light
C

Signaling Lights

B

1.95” (50mm);
1.76” (45mm)
minimum

Ø 0.137”	
(3.5mm)

Illuminated Pushbuttons

> 1.56” (40mm)
Large Mushroom

Ø 0.878”
(22.3mm)

Selector Switches
D

1.17” (30mm)
*See note.

Illuminated Selector Switches

1.The Ø 0.137” (Ø 3.5mm) recess is necessary when either the nameplate or anti-rotation ring is used.
2. *>1.404” (36mm) for 2- or 3-position.
	 >1.95” (50mm) for 4- or 5-position.

ø22.5

0.8

15

1.6t

18.5

Button
installed

21

AW-RP1B
Round Plastic Bezel
Panel Thickness
0.8 to 3.2

ø29

ø29

2.2
Key hole ø8

29.5
30

Waterproof Rubber
Gasket 0.5t

Finger-Safe Cover Dimensions
HW-VL6

HW-VL5

HW-VL4

HW-VL3

HW-VL2

APS-PVL

Circuit Breakers

Terminal Blocks

30

ø2

Contactors

70

30

13

93

6.5

R6

AW-QF1B
Square Full Shroud

24 (inside)
0
ø5 4.4)
4
:ø
(ID

648 	

	

3.5

3.5

AW-FP1B
Round Plastic w/Full Shroud
19.8

82.5

ø25

Button
installed

13

Timers

ø29

Extended

Flush

HW9Z-KL1
Lock-out Adaptor

9

ø31

.5

M22 P1.0

OB-31
Mounting Hole Rubber Plug

ø26

R42

ø32

Mounting Centers
50 min.

ø27.4

9

M22 P1.0

18.6

ø22

OCW-11
Pushbutton Rubber Boot

ø32

OLW-C
Metal Button Guard

ø31

OGL-31
Anti-Rotation Ring

10.2

Relays & Sockets

Accessory Dimensions

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series
Switches & Pilot Devices

Component Construction and General Instructions — TW Series
Instructions for Switches and Pilot Devices
TW Series: Adjustment for Panel Thickness
The panel thickness ring provides adjustment from 0.04” to 0.24” (1 to 6mm)
in 0.004” (0.1mm) increments. Rotate the ring until the markings around the
periphery are aligned for the desired thickness, as shown below.

Signaling Lights

Scale on Adjustment (in 0.1 mm)
0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0

0.1 mm
1

2

3

4

5

1 mm

Panel Thickness Scale
(in 1 mm on the operator)

6

A
3
5

4
6

Ex. Panel thickness 2.6 mm

Ex. Panel thickness 2 mm

Note: When a nameplate
or an anti-rotation ring
is used, add 0.03” 	
(0.8mm) to the panel
thickness dimension.

An adjustment for panel thicknesses shown below can be made quickly by using
the contact block remover tool.

Tool TW-KC1

1.6 mm

Relays & Sockets

2
4
6

3
5

2.3 mm
3.5 mm

Timers

1 mm

2 mm
3.2 mm



Contactors
Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) • USA & Canada

649

Switches & Pilot Devices

Signaling Lights

Switches & Pilot Devices

ø22mm - TW Series

Instructions continued
Pilot Lights and Pushbuttons
IMPORTANT: Install the body of the TW control unit with the panel thickness scale facing up.

Octagonal and Round Bezels
Octagonal and round bezels screw into the operator. Use a locking ring wrench (optional) for secure tightening and easy removal. Round flush and extended buttons
snap onto the operator base. Mushroom buttons screw onto the operator base.
Every round lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be
printed and placed in the lens.

Round
Marking
Unit

Lens

Relays & Sockets

Insert marking
plate under lens

Press in round flush and
extended lens. 	
Screw in mushroom lens

Marking
Plate
Press in

Square Bezels
Square bezels are installed in a 3-step procedure. First install the base plate from the front. Then install the lock nut using the nut locking wrench (optional). Finally,
install the square bezel, which snap-fits onto the base plate. Square buttons also snap onto the operator base.
Every square lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be
printed and placed in the lens. Square units include a round waterproof lens which screws into the operator. The square outer lens snaps on.

Insert

Insert marking
plate under lens

Marking Plate

Insert marking
plate under lens

Square Lens
Press in

Illuminated Pushbutton

Pilot Light

Square Lens

Timers

Square
Marking
Units

Marking Plate
Lens Retainer

To remove square lens from operator, place a screwdriver under the indentation on the side of the lens. To remove the marking plate, place a screwdriver under the
indentation and lift out the plate. The lens retainer can be removed by pressing a 3/16” screwdriver into one of the recesses.

Terminal Blocks

Contactors

Waterproof Lens

Marking Plate Engraving Area

Circuit Breakers

Shape
Round

Engraving Area

Used With

Part Number

Ø 0.55” (14mm)

Illuminated pushbuttons

ALW2B

Ø 0.55” (14mm)

Pilot lights

APW2B

Mushroom

Ø 0.55” (14mm)

Illuminated mushroom

Square

q 0.83” (21mm)

Square pilot lights

APQW1B

Square

q 0.83” (21mm)

Square illuminated pushbuttons

ALQW2B

650 	

	

ALW3B

www.IDEC.com

Switches & Pilot Devices

ø22mm - TW Series

Selector Switches
The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the
handle and then press handle into the operator, as shown below.
Recess

Press in 	
color insert

Selector Switch
(non-illuminated)

Signaling Lights

Press in
handle

Illuminated
Selector Switch
Remove color insert before pulling out the handle.

                   

3-Postion, 45º

4-Postion, 45º

0
1

2

1

1

2

2

5-Postion, 30º
2

3

Relays & Sockets

Standard Operating Positions
2-Postion, 90º

Switches & Pilot Devices

Instructions, continued

3

1

4

5

4

Positions: Non-Illuminated 3-Position Operators
1

0

1

1

2

0

0

2

Timers

2

Installation
TW Pilot Lights

Terminal X1 = Positive	
Terminal X2 = Negative
Contactors

Make sure slot 	
is facing up

TW Illuminated Pushbuttons,	
TW Selector Switches	
(AC Transformer or Full Voltage)

Terminal Blocks

Lamp holder is installed as shown, 	
due to polarity. 	
Lead holder (used with two stacks of
contact blocks ) does not have polarity.

Installation of LED Illuminated Units
AC transformers are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. (Diode
with DC power supply to protect against surges and noise.)
LED

Terminal
X2

Circuit Breakers

Ter minal
X1

Diode
Make sure that LED illuminated units are installed with correct polarity, as indicated at the terminals.

800-262-IDEC (4332) • USA & Canada

651



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Create Date                     : 2012:05:07 11:31:21-07:00
Creator                         : Adobe InDesign CS5.5 (7.5.1)
Modify Date                     : 2012:10:31 16:54:34-07:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2012:10:31 16:54:34-07:00
Creator Tool                    : Adobe InDesign CS5.5 (7.5.1)
Format                          : application/pdf
Document ID                     : uuid:f7a67be8-62c9-8546-84bf-bee38a096dd9
Instance ID                     : uuid:f50d12ec-cf60-e745-b483-1a277eff5c3f
Producer                        : Adobe PDF Library 9.9
Page Layout                     : TwoPageRight
Page Count                      : 41
EXIF Metadata provided by EXIF.tools

Navigation menu