440398 Catalog
121283-Attachment 121283-Attachment 121283-Attachment 000334 Batch8 unilog cesco-content
2014-09-27
: Pdf 440398-Catalog 440398-Catalog 000334 Batch8 unilog
Open the PDF directly: View PDF
.
Page Count: 41

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
611
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
TW Series — 22mm NEMA Style Pushbuttons
Key features:
• TWNEMAStyleSwitcheswithsnap-oncontacts
• Corrosionresistantoctagonalchromeplatedlockingbezel
• Snap-on10Acontactblocks
• IncandescentorLEDillumination
• Slowmake,doublebreak,selfcleaningcontacts
• Modularconstructionformaximumexibility
• NEMA4XandIP65watertight/oiltightpanel
• Availableassembledorassub-components
• LargeM3.5screwterminalswithcaptivesemsplate
IDEChasyour22mmswitchingneedscovered.
Buttonstylesincludeush,extended,mushroom,orsquareandallbodiesare
craftedfromfracture-resistantnylon.
Allilluminatedunitsfeaturetwolensestyles,onethatmaximizeslightdisper-
sion,theotheraccommodatesdirectlensengraving.
Selfcleaningcontactmechanismsallowforawidecurrentrating,5mAto10A,
whichreducestheneedforvariouscontactmaterials.
Whenlookingfora22mmswitchthatisdurable,easytouse,andversatile,then
IDEC’sTWseriesisyoursolution.
ULListed
FileNo.E68961
CSAApproved
FileNo.LR21451 FileNo.DK95-01696

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
612 www.IDEC.com
Specifications
Conforming to Standards EN60947-1,EN60947-5-1,VDE0660-200,UL508,CSAC22-2No.14
Approvals
FileNo.E68961
®
FileNo.LR21451 CerticateNo.
2030010305027380
RegistrationNo:J9551802(E-Stops)
RegistrationNo:J9551803(Allotherswitches)
RegistrationNo:J9551804(PilotLights)
CSA:pushbuttonsandselectorswitches:A600pilotlightsandilluminatedpushbuttons,directsupplypilot
lightsandilluminatedpushbuttonswithintegraltransformer(100/110,115,120,200/220,230,240,380,
400/440,480V)
UL: pushbuttonsandselectorswitches:A600pilotlightsandilluminatedpushbuttons,directsupplypilotlights
andilluminatedpushbuttonswithintegraltransformer(100/110,115,120,200/220,230,240,380,400/440,
480V)
TÜV:pushbuttonsandselectorswitches:A600=P600(NO,NC)/Q600(NO-EM,NC-LB)pilotlightsandillumi-
natedpushbuttons,directsupplypilotlightsandilluminatedpushbuttonswithintegraltransformer(100/110,
115,120,200/220,230,240,380,400/440,480V)
Operating Temperature Operation:–25to+50°C(withoutfreezing),Storage:–40to+80°C(withoutfreezing)
Vibration Resistance 5to55Hz,100m/sec2(10g)conformingtoIEC6068-2-6
Shock Resistance 1000m/sec2(100g)conformingtoIEC6068-2-7
Electric Shock Protection Class0conformingtoIEC60536
Degree of Protection
(conforming to IEC60529)
(conforming to NEMA ICS6-110)
IP65fromfrontofthepanel;(IP54forkeyswitches)
IP20(TypeHW-Fcontactblock)
Type1,2,3,3R,3S,4,4X,5,12,13(Type1,2,3R,5,12,13forkeyswitches)
Mechanical Life Momentarypushbuttons:5,000,000(900operationsperhour)
Allotherswitches:500,000
Pollution Degree (conforming to IEC60947-1) 3forswitchesnotusingatransformer,2forswitchesusingatransformer
Rated Operational Characteristics
AC-15:A600orUe=250V,le=3A(NO,NC,NO-EM,NC-LB)
DC-13:P600orUe=125V,le=1.1A(NO,NC)
DC-13:Q600orUe=125V,le=0.9A(NO-EM,NC-LB)
Rated Insulation Voltage 600V
Rated Switching Over-Voltage Lessthan4kV,conformingtoIEC60947-1
Rated Impulse Withstanding Voltage 4kVforcontactcircuit,2.5kVforlampcircuit
Rated Thermal Current 10Amp
Minimum Switching Capacity 5mAat3VAC/DC
Contact Operation SlowbreakNCorslowmakeNO,self-cleaning
Recommended Terminal Torque 0.8Nm(7.1inlb.)
External Short-Circuit Protection 10A250VfuseconformingtoIEC60269-1
Applicable Wire Size Minimum1x22AWG,max.2x14AWGor1x12AWG
Contact Resistance Initialcontactresistanceof50mΩorless
Contact Gap 4mm(NOandNC),2mm(NO-EMandNC-LB)
Electrical Reliability MTBF<1faultfor10millionoperationcycles(3VDC,5mA)
Lamp Ratings Incandescent:1W
LEDs:6V:17mAmax,12/24V:11mAmax,120/240V:10mAmax
Horsepower Rating 1/4HP@120V(single-phase,non-reversingmotor);1HP@240V(3phase,non-reversingmotor)
Maximum Inrush Current 40A(40ms)
Contact Material Silver
Contact Ratings
Pushbuttons
Illuminated Pushbuttons
Selector Switches
Illuminated Selector Switches
Pushbutton Selectors
ContactBlock TypeHW-C/HW-F
RatedInsulationVoltage 600V
RatedContinuousCurrent 10A
ContactRatingsbyUtilizationCategory
IEC60947-5-1
AC-15(A600)
DC-13(P600)
Characteristics
Contact Ratings by Utilization Category
OperationalVoltage 24V 48V 50V 110V 220V 440V
OperationalCurrent
AC50/60Hz AC-12Controlofresistiveloadsandsolidstateloads 10A —10A 10A 6A 2A
AC-15Controlofelectromagneticloads(>72VA) 10A —7A 5A 3A 1A
DC DC-12Controlofresistiveloadsandsolidstateloads 8A 5A —2.2A 1.1A —
DC-13Controlofelectromagnets 5A 2A —1.1A 0.6A —

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
613
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Pushbuttons (Assembled)
Assembled Pushbuttons
A B ( ) W 1 10 ( ) – B
Function
B: Momentary
O: Maintained
K: KeyOn/OffLock
Bezel Shape
Blank:Octagonal
F: FullShroud
G: MushroomShroud
Q: Square
Button Color
B: Black G: Green W:White
R: Red S: Blue Y: Yellow
Terminal Style
Blank:Standard
N:Fingersafe(IP20)
Contact Arrangement
10:1NO 01:1NC
20:2NO 02:2NC
11:1NO-1NC 22:2NO-2NC
Button Shape
1: Flush
2: Extended
3: MushroomHeadØ29mm
4: MushroomHeadØ40mm
Series Designation
W:TWSeries
Tobeusedforinterpretingpartnumbersonly,notforpartnumberdevelopment.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
614 www.IDEC.com
Non-Illuminated Pushbuttons (Assembled) continued
Non-Illuminated Pushbuttons
Style Contacts Momentary Action Maintained Action
Flush
1NO
1NC
1NO-1NC
2NO
2NC
ABW110-j
ABW101-j
ABW111-j
ABW120-j
ABW102-j
AOW110-j
AOW101-j
AOW111-j
AOW120-j
AOW102-j
Extended
1NO
1NC
1NO-1NC
2NO
2NC
ABW210-j
ABW201-j
ABW211-j
ABW220-j
ABW202-j
AOW210-j
AOW201-j
AOW211-j
AOW220-j
AOW202-j
Recessed
1NO
1NC
1NO-1NC
2NO
2NC
ABFW110-j
ABFW101-j
ABFW111-j
ABFW120-j
ABFW102-j
AOFW110-j
AOFW101-j
AOFW111-j
AOFW120-j
AOFW102-j
ExtendedwithFull
Shroud
1NO
1NC
1NO-1NC
2NO
2NC
ABFW210-j
ABFW201-j
ABFW211-j
ABFW220-j
ABFW202-j
AOFW210-j
AOFW201-j
AOFW211-j
AOFW220-j
AOFW202-j
Ø29mm
MushroomHead
1NO
1NC
1NO-1NC
2NO
2NC
ABW310-j
ABW301-j
ABW311-j
ABW320-j
ABW302-j
AOW310-j
AOW301-j
AOW311-j
AOW320-j
AOW302-j
Ø40mm
MushroomHead
1NO
1NC
1NO-1NC
2NO
2NC
ABW410-j
ABW401-j
ABW411-j
ABW420-j
ABW402-j
AOW410-j
AOW401-j
AOW411-j
AOW420-j
AOW402-j
Ø40mm
MushroomHead
withFullShroud
1NO
1NC
1NO-1NC
2NO
2NC
ABGW410-j
ABGW401-j
ABGW411-j
ABGW420-j
ABGW402-j
AOGW410-j
AOGW401-j
AOGW411-j
AOGW420-j
AOGW402-j
SquareFlush
1NO
1NC
1NO-1NC
2NO
2NC
ABQW110-j
ABQW101-j
ABQW111-j
ABQW120-j
ABQW102-j
AOQW110-j
AOQW101-j
AOQW111-j
AOQW120-j
AOQW102-j
SquareExtended
1NO
1NC
1NO-1NC
2NO
2NC
ABQW210-j
ABQW201-j
ABQW211-j
ABQW220-j
ABQW202-j
AOQW210-j
AOQW201-j
AOQW211-j
AOQW220-j
AOQW202-j
KeylockPushOn/
Off
1NO
1NC
1NO-1NC
2NO
2NC
AKW210
AKW201
AKW211
AKW220
AKW202
–
1. Inplaceofj,specifytheButtonColorCodefromtable.
2. Forsub-assembledpartnumbers,seenextpage.
3. Foraccessories,seepage643.
4. Fordimensions,seepage645.
5. Keyedswitchesaresuppliedwithtwokeys.Allunitsarekeyedalike.
j Button Color Codes
Color Code
Black B
Green G
Red R
Blue S
Yellow Y
White W

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
615
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Pushbuttons (Sub-Assembled)
Contact Blocks + Operator + Button = Complete Part
Operators
Style Part Number
Momentary Maintained
RoundFlush/Extended
ABW-100 AOW-100
RoundwithFullShroud/
Recessed
ABFW-200 AOFW-200
Ø40mm,Ø29mm
MushroomHead
ABW-300 AOW-300
Ø40mmMushroom
HeadwithFullShroud
ABGW-400 AOGW-400
SquareFlush/Extended
ABQW-100 AOQW-100
KeylockPushOn/Off
—AKW-200
Buttons
Style Part Number
RoundFlush
ABW1B-j
RoundExtended
ABW2B-j
Ø29mmMushroom
ABW3B-j
Ø40mmMushroom
ABW4B-j
SquareFlush
ABQW1B-j
SquareExtended
ABQW2B-j
Inplaceofjspecifythebuttoncolorcodefromtable
Contact Blocks
Style Part Number
1NO 1NC
StandardEx-
posedScrew HW-C10
HW-C10R
(earlymake)
HW-C01
HW-C01R
(latebreak)
Fingersafe
(IP20),CE
marked HW-F10
HW-F10R
(earlymake)
HW-F01
HW-F01R
(latebreak)
DummyBlock
TW-DB
1. Dummyblocks(nocontacts)areusedwithanodd
numberofcontactblocks.
2. Useofearlyandlatebreakcontactscreatesamake
beforebreakfunction
j Button Color Codes
Color Code
Black B
Green G
Red R
Blue S
Yellow Y
White W

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
616 www.IDEC.com
Stop Switches (Assembled)
Assembled Stop Switches
A V (L) W 4 (B) (99) 11 (D) (N) – R – (24V)
Function
V: Pushlock Turn Reset
Y: Push-Pull
X: Pushlock Key Reset
Illumination
Blank: None
L: Illuminated
Series Designation
W: TW Series
Button/Lens Size
3: 29mm Mushroom
4: 40mm Mushroom
Lens Type
(illuminated units only)
Blank: Standard (ribbed)
B: Engravable (smooth with insert)
Illuminated Circuit
(illuminated unit only)
99: Full Voltage (lamp determines voltage)
126: 120V AC Step Down Transformer
246: 240V AC Step Down Transformer
486: 480V AC Step Down Transformer
Lamp Voltage
(full voltage illuminated units only)
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120V AC (LED only)
240V: 240V AC (LED only)
Button/Lens Color
A: Amber R: Red W: White
G: Green S: Blue Y: Yellow
B: Black
Contact Terminal Style
Blank: Standard
N: Fingersafe (IP20)
Lamp Type
(illuminated units only)
Blank: Incandescent
D: LED
Contact Arrangement
10: 1NO 01: 1NC
20: 2NO 02: 2NC
11: 1NO/1NC 22: 2NO/2NC
To be used for interpreting part numbers only, not for part number development.

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
617
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Stop Switches (Assembled), continued
Non-Illuminated Stop Switches
Style Contacts Part Number
Ø 40mm Pushlock
Turn Reset*
1NO
1NC
1NO-1NC
2NO
2NC
AVW410-R*
AVW401-R*
AVW411-R*
AVW420-R*
AVW402-R*
Ø 29mm Pushlock
Turn Reset*
1NO
1NC
1NO-1NC
2NO
2NC
AVW310-R*
AVW301-R*
AVW311-R*
AVW320-R*
AVW302-R*
Ø 40mm Push-Pull
1NO
1NC
1NO-1NC
2NO
2NC
AYW410-j
AYW401-j
AYW411-j
AYW420-j
AYW402-j
Ø 40mm Pushlock
Key Reset *
1NO
1NC
1NO-1NC
2NO
2NC
AXW410- R*
AXW401- R*
AXW411- R*
AXW420- R*
AXW402- R*
1. *Available in Red only.
2. In place of j, specify the Button Color Code from table.
3. For sub-assembled part numbers, see next page.
4. For accessories, see page 643.
5. For dimensions, see page 645.
Illuminated Stop Switches
Style Type Contacts Part Number
Ø 40mm Pushlock
Turn Reset Type
Transformer
1NO-1NC
2NO
2NC
AVLW4 m 11n-R*
AVLW4 m 20n-R*
AVLW4 m 02n-R*
Full Voltage
1NO-1NC
2NO
2NC
AVLW49911n-R*-l
AVLW49920n-R*-l
AVLW49902n-R*-l
Ø 29mm Pushlock
Turn Reset
Transformer
1NO-1NC
2NO
2NC
AVLW3m11n-R*
AVLW3m20n-R*
AVLW3m02n-R*
Full Voltage
1NO-1NC
2NO
2NC
AVLW39911n-R*-l
AVLW39920n-R*-l
AVLW39902n-R*-l
Ø 40mm Push-Pull
Transformer
1NO-1NC
2NO
2NC
AYLW4 m 11n-k
AYLW4 m 20n-k
AYLW4 m 02n-k
Full Voltage
1NO-1NC
2NO
2NC
AYLW49911n-k-l
AYLW49920n-k-l
AYLW49902n-k-l
1. *Available in red only.
2. In place of k, specify the Lens Color Code (see table above).
3. In place of l, specify the Full Voltage Code (lamp voltage) (see table above).
4. In place of m, specify the Transformer Voltage Code (see table above).
5. In place of n, specify the Lamp Type Code from table above.
6. For sub-assembly part numbers, see next page.
7. For accessories, see page 643.
8. For dimensions, see page 645.
j Button Color Codes
Color Code
Black B
Green G
Red R
Blue S
White W
Yellow Y
k LED/Lens Color Codes
Color Code
Amber A
Green G
Red R
Blue S
White W
l Full Voltage Codes
Voltage Code
6V AC/DC 6V
12V AC/DC 12V
24V AC/DC 24V
120V AC 120V (LED only)
240V AC 240V (LED only)
m Transformer Voltage Codes
Voltage Code
120VAC
240VAC
480VAC
126
246
486
Transformers step down to 6V.
n Lamp Type Codes
Lamp Code
Incandescent Blank
LED D

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
618 www.IDEC.com
Stop Switches (Sub-Assembled)
Transformer/
Adaptor* + Contacts + Lamp Holder + Operator + Lamp + Button or Lens = Complete Part
*Not applicable for full voltage units
Operators
Style Part Number
Non-Illuminated Illuminated
Ø 29/Ø 40mm Push-
lock Turn Reset
AVW-300 AVLW3-0600
Ø 40mm Push-Pull
AYW-400 AYLW4-0600
Ø 40mm Pushlock
Key Reset
AXW-300 —
Buttons
Style Part Number
Ø 40mm Pushlock Turn Reset
AVW4B-R*
Ø 29mm Pushlock Turn Reset
AVW3B-R*
Ø 40mm Push-Pull
AYW4B-j
Ø 40mm Pushlock Key Reset
AXW4B-R*
1. *Available in Red only
2. In place of j, specify the button color code from table.
Contact Blocks
Style Voltage Part Number
LED
6V AC/DC LSTD-6k
12V AC/DC LSTD-1k
24V AC/DC LSTD-2k
120V AC LSTD-H2k
240V AC LSTD-M4k
Incandescent 6V AC/DC IS-6
12V AC/DC IS-12
24V AC/DC IS-24
1. In place of k, specify the LED color code.
2. The LED contains a current-limiting resistor and a
protection diode.
j Button Color Codes
Color Code
Black B
Green G
Red R
Blue S
White W
Yellow Y
k LED/Lens Color Codes
Color Code
Amber A
Green G
Red R
Blue S
White W

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
619
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Stop Switches (Sub-Assembled) continued
Lenses
Style Part Number
Standard Engravable
Ø 29mm Head Pushlock Turn Reset
AVLW3LU-R* AVLW3BLU-R*
Ø 40mm Head Pushlock Turn Reset
AVLW4LU-R* AVLW4BLU-R*
Ø 40mm Head Push Pull
AYLW4LU-kAYLW4BLU-k
1. In place of k, specify the lens color code from table on previous page.
2. *Available only in red
3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engrav-
able insert.
Lamp Circuit Components
Style Application Part Number
Short Lamp Holder
Used with a Half-size
Transformer and one
contact block
TW-LH1
Long Lamp Holder
Used with Full-size
Transformer and two
contact blocks
Used with Half-size
Transformer and three
contact blocks
Used with Full Voltage
Adaptor and two contact
blocks
TW-LH2
Lead Holder
Used with TW-LH2
holder when using four
contact blocks
HW-LH3
Transformers/Full Voltage Modules
Style Description Part Number
Full Size Transformer
Standard
120V AC TW-T126B
240V AC TW-T246B
480V AC TW-T486B
Fingersafe
120V AC TW-F126B
240V AC TW-F246B
480V AC TW-F486B
Half Size Transformer 120V AC TW-T126SB
240V AC TW-T246SB
Full voltage model (use with even
number of contacts) Standard TW-DA1B
Fingersafe TW-DA1FB
Full voltage model (use with odd
number of contacts) Standard HW-DA1B
Fingersafe HW-DA1FB
All Transformers step down to 6V (use 6V lamp).
Contact Blocks
Style Part Number
1NO 1NC
Standard Exposed Screw HW-C10
HW-C10R
(early make)
HW-C01
HW-C01R
(late break)
Fingersafe (IP20), CE marked HW-F10
HW-F10R
(early make)
HW-F01
HW-F01R
(late break)
Dummy Block
TW-DB
1. Dummy blocks (no contacts) are used with an odd number of contact blocks.
2. Use of early and late break contacts creates a make before break function

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
620 www.IDEC.com
Pilot Lights (Assembled)
Assembled Pilot Lights
A P (Q) W 1 (B) (99) (D) – R – (24V)
Function
P:PilotLight
Bezel Shape
Blank:Octagonal(roundlenses)
Q:Square
Series Designation
W:TWSeries
Lens Shape
1:Flat
2:Dome
Lens Type
Blank:Standard(ribbed)
B:Engravable(smoothwithinsertincluded)
Illumination Circuit
99: FullVoltage(lampdeterminesvoltage)
126: 120VACStepDownTransformer
246: 240VACStepDownTransformer
486: 480VACStepDownTransformer
Lamp Voltage
(FullVoltageUnitsOnly)
6V: 6VAC/DC
12V: 12VAC/DC
24V: 24VAC/DC
120V: 120VAC(LEDonly)
240V: 240VAC(LEDonly)
Lens Color Code
A: Amber
G: Green
R: Red
S: Blue
W:White
Y: Yellow
Lamp Type
Blank:Incandescent
D:LED
1. Useonlywheninterpretingpartnumbers.Donotusefordevelopingpartnumbers.
2. Alltransformersstepdownto6V.

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
621
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Pilot Lights (Assembled) continued
Assembled Pilot Lights
Style Type Voltage Part Number
RoundFlat
Transformer
120VAC
240VAC
480VAC
APW1126m-k
APW1246m-k
APW1486m-k
FullVoltage —APW199m-k-l
Dome
Transformer
120VAC
240VAC
480VAC
APW2126m-k
APW2246m-k
APW2486m-k
FullVoltage —APW299m-k-l
SquareFlat
Transformer
120VAC
240VAC
480VAC
APQW1B126m-k
APQW1B246m-k
APQW1B486m-k
FullVoltage —APQW1B99m-k-l
1. Inplaceofk,specifytheLensColorCodefromtablebelow.
2. Inplaceofl,specifytheFullVoltageCodefromtablebelow.
3.Inplaceofm,specifytheLampTypeCodefromtablebelow.
4. Foraccessories,seepage643.
5. Fordimensions,seepage645.
6. Forsub-assemblypartnumbers,seenextpage.
7.YellowpilotlightcomeswithwhiteLED.
k Lens Color Codes
Color Code
Amber A
Green G
Red R
Blue S
White W
Yellow Y
l Full Voltage Codes
Voltage Code
6VAC/DC 6V
12VAC/DC 12V
24VAC/DC 24V
120VAC 120V(LEDonly)
240VAC 240V(LEDonly)
m Lamp Type Codes
Lamp Code
Incandescent Blank
LED D

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
622 www.IDEC.com
Pilot Lights (Sub-Assembled)
Transformer + Operator + Lamp + Lens = Complete Part
*Transformernotrequiredforfullvoltageunits.
Operators
Style Part Number
RoundDome/Flat
APW-199
Square
UPQW-199
Sameoperatorisusedforfullvoltageasfor
transformercompletedunits.
Lenses
Style Part Number
Standard Engravable
Dome
APW2LU-k—
RoundFlat
APW1LU-k APW1BLU-k
SquareFlat
—APQW1BLU-k
1. Inplaceofk,specifytheLensColorCodefromtable.
2. Standardlenseshavearibbedlenstoenhancelight
dispersion.Markinglensesaresmoothandincludean
engravableinsert.
Lamps
Style Voltage Part Number
LED
6VAC/DC LSTD-6k
12VAC/DC LSTD-1k
24VAC/DC LSTD-2k
120VAC LSTD-H2k
240VAC LSTD-M4k
Incandescent 6VAC/DC IS-6
12VAC/DC IS-12
24VAC/DC IS-24
1. Inplaceofk,specifytheLEDcolorcode.
2. TheLEDcontainsacurrent-limitingresistoranda
protectiondiode.
3.YellowLEDnotavailable.UsewhiteLED.
Transformers
Style Description Part Number
Standard
120VAC TW-T126B
240VAC TW-T246B
480VAC TW-T486B
Fingersafe
120VAC TW-F126B
240VAC TW-F246B
480VAC TW-F486B
AllTransformersstepdownto6V(use6Vlamp).
k LED/Lens Color Codes
Color Code
Amber A
Green G
Red R
Blue S
White W
Yellow Y
Ifclearlensisdesired,use
whitemarkinglensand
removeengravinginsert

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
623
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Pushbuttons (Assembled)
Assembled Illuminated Pushbuttons
A L (F) W 2 (B) 99 11 (D) (N) – R – (24V)
Function
L:MomentaryAction
OL:MaintainedAction
Bezel Shape
Blank:Octagonal(roundlenses)
F:FullShroud(roundlenses)
Q:Square
Series Designation
W:TWseries
Lens Shape/Size
2:StandardExtended(roundorsquare)
3:29mmMushroom
4:40mmMushroom
Lens Type
Blank:Standard(ribbed)
B:Engravable(smoothwithinsert)
Illumination Circuit
99: FullVoltage(lampdeterminesvoltage)
126: 120VACStepDownTransformer
246: 240VACStepDownTransformer
486: 480VACStepDownTransformer
Lamp Voltage
(FullVoltageUnitsOnly)
6V: 6VAC/DC
12V: 12VAC/DC
24V: 24VAC/DC
120V: 120VAC(LEDonly)
240V: 240VAC(LEDonly)
Lens Code
A: Amber
G: Green
R: Red
S: Blue
W:White
Y: Yellow
Contact Terminal Style
Blank:Standard
N: Fingersafe
Lamp Type
Blank: IncandescentLamp
D: LEDLamp
Contact Arrangement
10:1NO 01:1NC
20:2NO 02:2NC
11:1NO-1NC 22:2NO-2NC
1. Useonlywheninterpretingpartnumbers.Donotusefordevelopingpartnumbers.
2. Transformersstepdownto6V.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
624 www.IDEC.com
Illuminated Pushbuttons (Assembled)
Illuminated Pushbuttons
Style Contacts Part Number
Momentary Maintained
ExtendedLens Transformer
1NO-1NC
2NO
2NC
ALW2m11n-k
ALW2m20n-k
ALW2m02n-k
AOLW2m11n-k
AOLW2m20n-k
AOLW2m02n-k
FullVoltage
1NO-1NC
2NO
2NC
ALW29911n-k-l
ALW29920n-k-l
ALW29902n-k-l
AOLW29911n-k-l
AOLW29920n-k-l
AOLW29902n-k-l
ExtendedLenswithFullShroud Transformer
1NO-1NC
2NO
2NC
ALFW2m11n-k
ALFW2m20n-k
ALFW2m02n-k
AOLFW2m11n-k
AOLFW2m20n-k
AOLFW2m02n-k
FullVoltage
1NO-1NC
2NO
2NC
ALFW29911n-k-l
ALFW29920n-k-l
ALFW29902n-k-l
AOLFW29911n-k-l
AOLFW29920n-k-l
AOLFW29902n-k-l
ø29mmMushroomLens Transformer
1NO-1NC
2NO
2NC
ALW3m11n-k
ALW3m20n-k
ALW3m02n-k
AOLW3m11n-k
AOLW3m20n-k
AOLW3m02n-k
FullVoltage
1NO-1NC
2NO
2NC
ALW39911n-k-l
ALW39920n-k-l
ALW39902n-k-l
AOLW39911n-k-l
AOLW39920n-k-l
AOLW39902n-k-l
ø40mmMushroomLens Transformer
1NO-1NC
2NO
2NC
ALW4m11n-k
ALW4m20n-k
ALW4m02n-k
AOLW4m11n-k
AOLW4m20n-k
AOLW4m02n-k
FullVoltage
1NO-1NC
2NO
2NC
ALW49911n-k-l
ALW49920n-k-l
ALW49902n-k-l
AOLW49911n-k-l
AOLW49920n-k-l
AOLW49902n-k-l
SquareExtended Transformer
1NO-1NC
2NO
2NC
ALQW2Bm11n-k
ALQW2Bm20n-k
ALQW2Bm02n-k
AOLQW2Bm11n-k
AOLQW2Bm20n-k
AOLQW2Bm02n-k
FullVoltage
1NO-1NC
2NO
2NC
ALQW2B9911n-k-l
ALQW2B9920n-k-l
ALQW2B9902n-k-l
AOLQW2B9911n-k-l
AOLQW2B9920n-k-l
AOLQW2B9902n-k-l
1. Inplaceofk,specifytheLensColorCode(seetable).Mushroomlensesnotavailableinyellow.
2. Inplaceofl,specifytheFullVoltageCode(lampvoltage)(seetable).
3. Inplaceofm,specifytheTransformerVoltageCode(seetable).
4.Inplaceofn,specifytheLampTypeCodefromtable.
5. Forsub-assemblypartnumbers,seenextpage.
6. Foraccessories,seepage643.
7. Fordimensions,seepage645.
8. Lightisindependentofswitchposition.
9.YellowpushbuttoncomeswithwhiteLED.
k LED/Lens Color Codes
Color Code
Amber A
Green G
Red R
Blue S
White W
Yellow Y
1. Mushroomlensesnot
availableinyellow.
2.Yellowpushbuttoncomes
withwhiteLED.
l Full Voltage Codes
Voltage Code
6VAC/DC 6V
12VAC/DC 12V
24VAC/DC 24V
120VAC 120V(LEDonly)
240VAC 240V(LEDonly)
m Transformer Voltage Codes
Voltage Code
120VAC 126
240VAC 246
480VAC 486
Transformersstepdownto6V
(use6Vlamp).
n Lamp Type Codes
Lamp Code
Incandescent Blank
LED D

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
625
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Pushbuttons (Sub-Assembled)
Transformer/
Adaptor* + Contacts + Lamp Holder + Operator + Lamp + Lens = Complete Part
*Notapplicableforfullvoltageunits
Operators
Style Part Number
Momentary Maintained
Extended ALW-0600 AOLW-0600
Extendedwith
FullShroud ALFW-0600 AOLFW-0600
ø29mm/ø40mm
Mushroom ALW3-0600 AOLW3-0600
Square/Extended ALQW-2B0600 AOLQW-2B0600
Lenses
Style Part Number
Standard Engravable
RoundExtended ALW2LU-kALW2BLU-k
ø29mm
MushroomHead* ALW3LU-kALW3BLU-k
ø40mm
MushroomHead* ALW4LU-kALW4BLU-k
SquareExtended —ALQW2BLU-k
1. Inplaceofk,specifythelenscolorcodefromtableonthebottomright.
2. *Mushroomlensnotavailableinyellow.
3. Standardlenseshaveribbedpattern,Engravablelensesaresmoothandincludean
engravableinsert.
Lamps
Style Voltage Part Number
LED
6VAC/DC LSTD-6k
12VAC/DC LSTD-1k
24VAC/DC LSTD-2k
120VAC LSTD-H2k
240VAC LSTD-M4k
Incandescent 6VAC/DC IS-6
12VAC/DC IS-12
24VAC/DC IS-24
1. Inplaceofk,specifytheLEDcolorcode.
2. TheLEDcontainsacurrent-limitingresistoranda
protectiondiode.
Lamp Circuit Components
Style Application Part Number
ShortLampHolder
Used withaHalf-size
Transformerandone
contactblock
TW-LH1
LongLampHolder
Used withFull-size
Transformerandtwo
contactblocks
Used with Half-size
Transformerandthree
contactblocks
Used with FullVoltage
Adaptorandtwocontact
blocks
TW-LH2
LeadHolder
Used withTW-LH2
holderwhenusingfour
contactblocks
HW-LH3
k LED/Lens Color Codes
Color Code Color Code
Amber A Blue S
Green GWhite W
Red RYellow Y
YellowLEDnotavailable.UsewhiteLED.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
626 www.IDEC.com
Illuminated Pushbuttons (Sub-Assembled) continued
Contact Blocks
Style Part Number
1NO 1NC
StandardExposedScrew HW-C10
HW-C10R
(earlymake)
HW-C01
HW-C01R
(latebreak)
Fingersafe(IP20),CEmarked HW-F10
HW-F10R
(earlymake)
HW-F01
HW-F01R
(latebreak)
DummyBlock
TW-DB
1. Dummyblocks(nocontacts)areusedwithanoddnumberofcontactblocks.
2. Useofearlyandlatebreakcontactscreatesamakebeforebreakfunction
Transformers/Full Voltage Modules
Style Description Part Number
FullSizeTransformer
Standard
120VAC TW-T126B
240VAC TW-T246B
480VAC TW-T486B
Fingersafe
120VAC TW-F126B
240VAC TW-F246B
480VAC TW-F486B
HalfSizeTransformer
120VAC TW-T126SB
240VAC TW-T246SB
Fullvoltagemodel(usewith
evennumberofcontacts) Standard TW-DA1B
Fingersafe TW-DA1FB
Fullvoltagemodel(usewith
oddnumberofcontacts) Standard HW-DA1B
Fingersafe HW-DA1FB
AllTransformersstepdownto6V(use6Vlamp).

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
627
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Selector Switches (Assembled)
Assembled Selector Switches
A S W 3 (1) (L) 20 (N) – 304
Function
S: SelectorSwitch
Series Designation
W:TWSeries
Number of Positions
2: 2-Position
3: 3-Position
4:4-Position
5:5-Position
Spring Return Action
Blank:Maintained
1: SpringreturnfromRight(2or3position)
2: SpringreturnfromLeft(2or3position)
3: 2-WayspringreturnfromLeftandRight
(3positiononly)
Circuit Number
(Standardcircuitsshownonfollowing
pagesand635.)
Contacts Terminal Style
Blank:standard
N:Fingersafe(IP20)
Contact Arrangement Code
10:1NO 01:1NC
20:2NO 02:2NC
40:4NO 04:4NC
11:1NO-1NC22:2NO-2NC
Operator Style Code
Blank: KnobOperator
L: LeverOperator
K: KeyOperator
1. Useonlywheninterpretingpartnumbers.Donotusefordevelopingpartnumbers.
2. Customcontactcongurationsavailable.
3. Customkeyremovablecodesavailable.
4. Portionsofpartnumberinside()areoptional.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
628 www.IDEC.com
Non-Illuminated Selector Switches (Assembled) continued
2-Position Selector Switches
Style Part Number
Contact
Mounting
Operator
Position Maintained Spring Return
from Right
Spring Return
from Left
LRLRLRLR
1NO 1
2
O
O
X
O
Knob
Lever
Key
ASW210
ASW2L10
ASW2K10
ASW2110
ASW21L10
ASW21K10
ASW2210
ASW22L10
ASW22K10
1NC 1
2
X
O
O
O
Knob
Lever
Key
ASW201-116
ASW2L01-116
ASW2K01-116
ASW2101-116
ASW21L01-116
ASW21K01-116
ASW2201-116
ASW22L01-116
ASW22K01-116
1NO
1NC
1
2
X
O
O
X
Knob
Lever
Key
ASW211
ASW2L11
ASW2K11
ASW2111
ASW21L11
ASW21K11
ASW2211
ASW22L11
ASW22K11
2NO 1
2
O
O
X
X
Knob
Lever
Key
ASW220
ASW2L20
ASW2K20
ASW2120
ASW21L20
ASW21K20
ASW2220
ASW22L20
ASW22K20
2NC 1
2
X
X
O
O
Knob
Lever
Key
ASW202-104
ASW2L02-104
ASW2K02-104
ASW2102-104
ASW21L02-104
ASW21K02-104
ASW2202-104
ASW22L02-104
ASW22K02-104
2NO
2NC
1
2
3
4
O
X
O
X
X
O
X
O
Knob
Lever
Key
ASW222
ASW2L22
ASW2K22
ASW2122
ASW21L22
ASW21K22
ASW2222
ASW22L22
ASW22K22
2NO
2NC
1
2
3
4
O
O
X
X
X
X
O
O
Knob
Lever
Key
ASW222-111
ASW2L22-111
ASW2K22-111
ASW2122-111
ASW21L22-111
ASW21K22-111
ASW2222-111
ASW22L22-111
ASW22K22-111

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
629
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Selector Switches (Assembled) continued
3-Position Selector Switches
Style Part Number
Contact
Mounting
Operator Position Maintained Spring Return from Right Spring Return from Left Spring Return Two-Way
LCRL
C
RL
C
RL
C
RL
C
R
2NO 1
2
X
O
O
O
O
X
Knob
Lever
Key
ASW320
ASW3L20
ASW3K20
ASW3120
ASW31L20
ASW31K20
ASW3220
ASW32L20
ASW32K20
ASW3320
ASW33L20
ASW33K20
2NC 1
2
O
X
X
X
X
O
Knob
Lever
Key
ASW302
ASW3L02
ASW3K02
ASW3102
ASW31L02
ASW31K02
ASW3202
ASW32L02
ASW32K02
ASW3302
ASW33L02
ASW33K02
2NO
2NC
1
2
3
4
X
O
O
X
O
O
X
X
O
X
X
O
Knob
Lever
Key
ASW322
ASW3L22
ASW3K22
ASW3122
ASW31L22
ASW31K22
ASW3222
ASW32L22
ASW32K22
ASW3322
ASW33L22
ASW33K22
2NO
2NC
1
2
3
4
X
X
O
O
O
X
X
O
X
O
O
X
Knob
Lever
Key
ASW322-309
ASW3L22-309
ASW3K22-309
ASW3122-309
ASW31L22-309
ASW31K22-309
ASW3222-309
ASW32L22-309
ASW32K22-309
ASW3322-309
ASW33L22-309
ASW33K22-309
2NO
2NC
1
2
3
4
O
O
O
O
X
O
X
O
O
X
O
X
Knob
Lever
Key
ASW322-310
ASW3L22-310
ASW3K22-310
ASW3122-310
ASW31L22-310
ASW31K22-310
ASW3222-310
ASW32L22-310
ASW32K22-310
ASW3322-310
ASW33L22-310
ASW33K22-310
4NO
1
2
3
4
X
O
X
O
O
O
O
O
O
X
O
X
Knob
Lever
Key
ASW340
ASW3L40
ASW3K40
ASW3140
ASW31L40
ASW31K40
ASW3240
ASW32L40
ASW32K40
ASW3340
ASW33L40
ASW33K40
4NC
1
2
3
4
O
X
O
X
X
X
X
X
X
O
X
O
Knob
Lever
Key
ASW304
ASW3L04
ASW3K04
ASW3104
ASW31L04
ASW31K04
ASW3204
ASW32L04
ASW32K04
ASW3304
ASW33L04
ASW33K04
1. Thetruthtableindicatestheoperatingpositionofcontactblockwhentheoperatorisswitchedtothatposition.
X=On(closedcontacts)
O=Off(opencontacts)
XX=OverlappingContacts:Remainon(closedcontacts)whenswitchismovedbetweenthesetwopositions.
2. Allknobandleverselectorswitchescomeinblack.Othercolorsareavailablebyorderingtheknoborleverseparately.
3. Everykeyselectorswitchusesanidenticalkey.Thekeyisremovableinanymaintainedposition.
4. Customcontactcongurationsareavailable,seepage635.
4-Position Selector Switch
Style Maintained
Contact
Mounting
Operator Position Part Number
123 4 1
2
3
4
2NO
2NC
1
2
3
4
X
O
O
O
O
X
O
O
O
O
X
O
O
O
O
X
Knob
Lever
ASW422-411
ASW4L22-411
5-Position Selector Switch
Style Maintained
Contact
Mounting
Operator Position Part Number
1234 5
1
2
3
4
5
2NO
2NC
1
2
3
4
X
O
O
O
O
X
O
O
O
O
O
O
O
O
X
O
O
O
O
X
Knob
Lever
ASW522-501
ASW5L22-501

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
630 www.IDEC.com
Non-Illuminated Selector Switches (Sub-Assembled)
Contact Blocks + Operator + Knob or Lever* + Color Insert* = Complete Part†
1. *Notneededwithkeytypeswitches.
2. †Knobtypeshown.
Operators
Style Positions Description Part Number
Knob/Lever
2
Maintained ASW200
Springreturnfromright ASW2100
Springreturnfromleft ASW2200
3
Maintained,Cam1
Maintained,Cam2
Maintained,Cam3
ASW300-1
ASW300-2
ASW300-3
Springreturnfromright,Cam1
Springreturnfromright,Cam2
ASW3100-1
ASW3100-2
Springreturnfromleft,Cam1
Springreturnfromleft,Cam2
ASW3200-1
ASW3200-2
Springreturnfromleft/right,Cam1
Springreturnfromleft/right,Cam2
ASW3300-1
ASW3300-2
4Maintained,StandardCam
Maintained,Cam1
ASW400
ASW400-1
5Maintained,Standardcam
Maintained,Cam1
ASW500
ASW500-1
Key 2
Maintained ASW2K00
Springreturnfromright ASW21K00
Springreturnfromleft ASW22K00
3
Maintained,Cam1
Maintained,Cam2
Maintained,Cam3
ASW3K00-1
ASW3K00-2
ASW3K00-3
Springreturnfromright,Cam1
Springreturnfromright,Cam2
ASW31K00-1
ASW31K00-2
Springreturnfromleft,Cam1
Springreturnfromleft,Cam2
ASW32K00-1
ASW32K00-2
Springreturnfromleft/right,Cam1
Springreturnfromleft/right,Cam2
ASW33K00-1
ASW33K00-2
1. Twokeysaresuppliedwitheverykeyswitch,allarekeyedalike,andremovablefromanymaintainedposition.
2. Lockingringsareincludedwithalloperators.Orderknobs,levers,andcolorinsertsseparately.
3. Differentcamsproducedifferentcontactactions.Fordetails,seepage635.
4. Keyswitchoperatorsuppliedwithblacksleeve.
Handles and Inserts
Style Part Number
Knob ASWHHY-j
Lever ASWHHL-j
Color
Insert TW-HC1-j
Contact Blocks
Style Part Number
1NO 1NC
StandardExposed
Screw HW-C10
HW-C10R
(earlymake)
HW-C01
HW-C01R
(latebreak)
Fingersafe(IP20),CE
marked HW-F10
HW-F10R
(earlymake)
HW-F01
HW-F01R
(latebreak)
DummyBlock
TW-DB
1. Pushrodcolorcode:
Green=NOcontactblock
Red=NCcontactblock.
2. Dummyblocks(nocontacts)areusedwithanodd
numberofcontactblocks.
j Handle/Insert Color Codes
Color Code
Black* B
Blue S
Green G
Red R
Yellow Y
White†W
*Colorinsertsnotavailableinblack.
†Knobandlevernotavailableinwhite.
Replacement Parts
Key Switch Black Sleeve AKW2B-B

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
631
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Selector Switches (Assembled)
Assembled Illuminated Selector Switches
A SL W 2 (2) 99 11 (D) (N) – (103) – R – (24V)
Function
SL:IlluminatedSelectorSwitch
Series Designation
W:TWseries
Number of Positions
2:2-Position
3:3-Position
Spring Return Action
Blank:Maintained
1:SpringreturnfromRight
2:SpringreturnfromLeft
3:Two-WayspringreturnfromLeftandRight
Illumination Circuit
99: FullVoltage(lampdeterminesvoltage)
126: 120VACStepDownTransformer
246: 240VACStepDownTransformer
486: 480VACStepDownTransformer
Lamp Voltage
(FullVoltageUnitsOnly)
6V: 6VAC/DC
12V: 12VAC/DC
24V: 24VAC/DC
120V: 120VAC(LEDonly)
240V: 240VAC(LEDonly)
Lens Color Code
A: Amber
G: Green
R: Red
S: Blue
W:White
Y: Yellow
Contact Circuit Number
Standardcircuitsarelistedonthe
followingpagesand635.
Contact Terminal Style
Blank:Standard
N: Fingersafe
Lamp Type
Blank:IncandescentLamp
D:LEDLamp
Contact Arrangement
10:1NO 01:1NC
20:2NO 02:2NC
40:4NO 04:4NC
11:1NO-1NC 22:2NO-2NC
1. Useonlywheninterpretingpartnumbers.Donotusefordevelopingpartnumbers.
2. Alltransformersstepdownto6V(use6Vlamp).

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
632 www.IDEC.com
Illuminated Selector Switches(Assembled) continued
Illuminated 2-Position Selector Switches
Style Part Number
Contact
Mounting
Operator
Position Lamp
Circuit Type
Maintained Spring Return from Right Spring Return from Left
LRLRLR
L R
1NO
1NC
1
2
O
X
X
O
Transformer
FullVoltage
ASLW2j11m-k
ASLW29911m-k-l
ASLW21j11m-k
ASLW219911m-k-l
ASLW22j11m-k
ASLW229911m-k-l
2NO 1
2
O
O
X
X
Transformer
FullVoltage
ASLW2j20m-k
ASLW29920m-k-l
ASLW21j20m-k
ASLW219920m-k-l
ASLW22j20m-k
ASLW229920m-k-l
2NC 1
2
X
X
O
O
Transformer
FullVoltage
ASLW2j02m-104-k
ASLW29902m-104-k-l
ASLW21j02m-104-k
ASLW219902m-104-k-l
ASLW22j02m-104-k
ASLW229902m-104-k-l
2NO
2NC
1
2
3
4
O
X
O
X
X
O
X
O
Transformer
FullVoltage
ASLW2j22m-k
ASLW29922m-k-l
ASLW21j22m-k
ASLW219922m-k-l
ASLW22j22m-k
ASLW229922m-k-l
Illuminated 3-Position Selector Switches, Maintained and Spring Return from Right
Style Part Number
Contact
Mounting
Operator Position
Lamp
Circuit Type
Maintained Spring Return From Right Spring Return from Left Spring Return Two-Way
LCRL
C
RL
C
RL
C
RL
C
R
2NO 1
2
X
O
O
O
O
X
Transformer
FullVoltage
ASLW3j20m-k
ASLW39920m-k-l
ASLW31j20m-k
ASLW319920m-k-l
ASLW32j20m-k
ASLW329920m-k-l
ASLW33j20m-k
ASLW339920m-k-l
2NC 1
2
O
X
X
X
X
O
Transformer
FullVoltage
ASLW3j02m-k
ASLW39902m-k-l
ASLW31j02m-k
ASLW319902m-k-l
ASLW32j02m-k
ASLW329902m-k-l
ASLW33j02m-k
ASLW339902m-k-l
2NO
2NC
1
2
3
4
X
O
O
X
O
O
X
X
O
X
X
O
Transformer
FullVoltage
ASLW3j22m-k
ASLW39922m-k-l
ASLW31j22m-k
ASLW319922m-k-l
ASLW32j22m-k
ASLW329922m-k-l
ASLW33j22m-k
ASLW339922m-k-l
2NO
2NC
1
2
3
4
X
X
O
O
O
X
X
O
X
O
O
X
Transformer
FullVoltage
ASLW3j22m-309-k
ASLW39922m-309-k-l
ASLW31j22m-309-k
ASLW319922m-309-k-l
ASLW32j22m-309-k
ASLW329922m-309-k-l
ASLW33j22m-309-k
ASLW339922m-309-k-l
2NO
2NC
1
2
3
4
O
O
O
O
X
O
X
O
O
X
O
X
Transformer
FullVoltage
ASLW3j22m-310-k
ASLW39922m-310-k-l
ASLW31j22m-310-k
ASLW319922m-310-k-l
ASLW32j22m-310-k
ASLW329922m-310-k-l
ASLW33j22m-310-k
ASLW339922m-310-k-l
4NO
1
2
3
4
X
O
X
O
O
O
O
O
O
X
O
X
Transformer
FullVoltage
ASLW3j40m-k
ASLW39940m-k-l
ASLW31j40m-k
ASLW319940m-k-l
ASLW32j40m-k
ASLW329940m-k-l
ASLW33j40m-k
ASLW339940m-k-l
4NC
1
2
3
4
O
X
O
X
X
X
X
X
X
O
X
O
Transformer
FullVoltage
ASLW3j04m-k
ASLW39904m-k-l
ASLW31j04m-k
ASLW319904m-k-l
ASLW32j04m-k
ASLW329904m-k-l
ASLW33j04m-k
ASLW339904m-k-l
1. Inplaceofj,specifytheTransformerVoltageCode.
2. Inplaceofk,specifytheLens/LEDColorCode.
3. Inplaceofl,specifytheFullVoltageCode.
4. InplaceofmspecifyLampTypeCode
5. Forcustomcontactcongurations,seepage635.
6. Lightisindependentofswitchposition.
7.YellowselectorswitchcomeswithwhiteLED.
l Full Voltage Codes
Voltage Code
6VAC/DC 6V
12VAC/DC 12V
24VAC/DC 24V
120VAC 120V(LEDonly)
240VAC 240V(LEDonly)
m Lamp Type Codes
Lamp Code
Incandescent Blank
LED D
j Transformer Voltage Codes
Voltage Code
120VAC 126
240VAC 246
480VAC 486
Transformersstepdownto6V
(use6Vlamp).
k LED/Lens Color Codes
Color Code
Amber A
Green G
Red R
Blue S
White W
Yellow Y

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
633
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Selector Switches (Sub-Assembled)
Transformer* + Contact Block + Operator + Lamp/Lead Holder†+ Lamp + Lens = Complete Part
*Fullvoltageunitsuseafullvoltageadaptor(TW-DA1B)insteadofatransformer.
†Lampholderisnotincludedwithoperators,orderseparately.
Leadholderisusedwhenusing3ormorecontactblocks.Orderseparately.
Operators
Style Positions Description Part Number
2
Maintained ASLW200
Springreturnfromright ASLW2100
Springreturnfromleft ASLW2200
3
Maintained,cam1
Maintained,cam2
Maintained,cam3
ASLW300-1
ASLW300-2
ASLW300-3
Springreturnfromright,cam1
Springreturnfromright,cam2
ASLW3100-1
ASLW3100-2
Springreturnfromleft,cam1
Springreturnfromleft,cam2
ASLW3200-1
ASLW3200-2
Springreturnfromleft/right,cam1
Springreturnfromleft/right,cam2
ASLW3300-1
ASLW3300-2
Differentcamsproducedifferentcontactaction.Fordetails,seeContactArrangements
onpage635.
Lenses (Knobs)
Style Part Number
Knob ASLWLU-k
Inplaceofk,specifythelenscolorcodefromtable.
Lamps
Style Voltage Part Number
LED
6VAC/DC LSTD-6k
12VAC/DC LSTD-1k
24VAC/DC LSTD-2k
120VAC LSTD-H2k
240VAC LSTD-M4k
Incandescent 6VAC/DC IS-6
12VAC/DC IS-12
24VAC/DC IS-24
1. Inplaceofk,specifytheLEDcolorcode.
2. TheLEDcontainsacurrent-limitingresistoranda
protectiondiode.
k LED/Lens Color Codes
Color Code
Amber A
Green G
Red R
Blue S
White W
Yellow Y
YellowLEDnotavailable.Use
whiteLED

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
634 www.IDEC.com
Illuminated Selector Switches (Sub-Assembled) continued
Contact Blocks
Style Part Number
1NO 1NC
StandardExposedScrew HW-C10
HW-C10R
(earlymake)
HW-C01
HW-C01R
(latebreak)
Fingersafe(IP20),CEmarked HW-F10
HW-F10R
(earlymake)
HW-F01
HW-F01R
(latebreak)
DummyBlock
TW-DB
1. Dummyblocks(nocontacts)areusedwithanoddnumberofcontactblocks.
2. Useofearlyandlatebreakcontactscreatesamakebeforebreakfunction
Lamp Circuit Components
Style Application Part Number
ShortLampHolder
Used withaHalf-size
Transformerandone
contactblock
TW-LH1
LongLampHolder
Used withFull-size
Transformerandtwo
contactblocks
Used with Half-size
Transformerandthree
contactblocks
Used with FullVoltage
Adaptorandtwocontact
blocks
TW-LH2
LeadHolder
Used withTW-LH2
holderwhenusingfour
contactblocks
HW-LH3
Transformers/Full Voltage Modules
Style Description Part Number
FullSizeTransformer
Standard
120VAC TW-T126B
240VAC TW-T246B
480VAC TW-T486B
Fingersafe
120VAC TW-F126B
240VAC TW-F246B
480VAC TW-F486B
HalfSizeTransformer
120VAC TW-T126SB
240VAC TW-T246SB
Fullvoltagemodel(usewith
evennumberofcontacts) Standard TW-DA1B
Fingersafe TW-DA1FB
Fullvoltagemodel(usewith
oddnumberofcontacts) Standard HW-DA1B
Fingersafe HW-DA1FB
AllTransformersstepdownto6V(use6Vlamp).

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
635
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Contact Arrangement Charts
How to Read Contact Arrangement Charts
Todeterminecontactblockmountingposition,rstmakesuretheselectorswitchisorientedasshownontheright
Contact Arrangement
Typeandquantityofswitch
contacts
Circuit Number
*N/D=Nodesignation
required
Contact Block
Mounting Position
Positionormounting
contactblocksonoperator
Operator Position
Truthtableindicatestheoper-
atingpositionofcontactblock
whenoperatorisswitchedto
thatposition.
Contact Block
Part Number
Partnumbertousewhen
orderingsub-assemblycontact
blocks,asrequiredforuse
withcorrespondingmounting
position
Contact Arrangement Chart: 2-Position Selector Switches
Style
Mounting
Position
Operator
Position Contact Block
Part Number Description
Operator Part Number
Contact Circuit
Number
Maintained Spring Ret.
from Rt.
Spring Ret.
from Lt.
LRLRLRLR
1NO N/D 1 O X HW-C10 Knob/Lever
Key
IlluminatedKnob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2 O O TW-DB
1NC 116 1 X O HW-C01 Knob/Lever
Key
IlluminatedKnob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2 O O TW-DB
1NO
1NC
N/D 1 O X HW-C10 Knob/Lever
Key
IlluminatedKnob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2 X O HW-C01
103 1 X O HW-C01 Knob/Lever
Key
IlluminatedKnob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2 O X HW-C10
1NO-EM
1NC-LB
600 1 O X HW-C10R Knob/Lever
Key
IlluminatedKnob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2 X O HW-C01R
601 1 X O HW-C01R Knob/Lever
Key
IlluminatedKnob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2 O X HW-C10R
2NO N/D 1 O X HW-C10 Knob/Lever
Key
IlluminatedKnob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2 O X HW-C10
2NC 104 1 X O HW-C01 Knob/Lever
Key
IlluminatedKnob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2 X O HW-C01
2NO
2NC
N/D
1 O X HW-C10
Knob/Lever
Key
IlluminatedKnob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2 X O HW-C01
3 O X HW-C10
4 X O HW-C01
111
1 O X HW-C10
Knob/Lever
Key
IlluminatedKnob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2 O X HW-C10
3 X O HW-C01
4 X O HW-C01
1. NO-EM,NC-LB=EarlyMake,LateBreak.
N/D=Nocircuitnumberdesignationrequiredinassembledselectorswitchpartnumber.
2. X=On(closedcontacts)O=Off(Opencontacts)
2
3
4
L
R
1

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
636 www.IDEC.com
Contact Arrangement Chart: 3-Position Selector Switches
Style
Mounting
Position
Operator Position
Contact Block
Part Number Description
Operator Part Number
Contact Circuit
Number
Maintained Spring Return
from Right
Spring Return
from Left Two-Way
LCRL
C
RL
C
RL
C
RL
C
R
1NO
1NC
202
1 X 0 0 HW-C10 Knob/Lever
Key
IlluminatedKnob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
2XX O HW-C01
203
1 0 XX HW-C01 Knob/Lever
Key
IlluminatedKnob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
2 O 0 X HW-C10
302
1 X 0 X HW-C10 Knob/Lever
Key
IlluminatedKnob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
2XX O HW-C01
303
1 0 X O HW-C01 Knob/Lever
Key
IlluminatedKnob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
2 O 0 X HW-C10
2NO
N/D
1 X 0 0 HW-C10 Knob/Lever
Key
IlluminatedKnob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
2 O 0 X HW-C10
301
1 X 0 X HW-C10 Knob/Lever
Key
IlluminatedKnob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
2 O 0 X HW-C10
2NC
304
1 0 X O HW-C01 Knob/Lever
Key
IlluminatedKnob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
2XX O HW-C01
N/D
1 0 XX HW-C01 Knob/Lever
Key
IlluminatedKnob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
2XX O HW-C01
2NO
2NC
N/D
1 X 0 0 HW-C10
Knob/Lever
Key
IlluminatedKnob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
2 0 0 X HW-C10
3 0 XX HW-C01
4XX 0 HW-C01
210
1 0 X X HW-C01
Knob/Lever
Key
IlluminatedKnob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
2 0 0X HW-C10
3 0 XX HW-C01
4 0 0 X HW-C10
308
1 X 0 X HW-C10
Knob/Lever
Key
IlluminatedKnob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
2XX 0 HW-C01
3 X 0 X HW-C10
4XX O HW-C01
309
1 X 0 X HW-C10
Knob/Lever
Key
IlluminatedKnob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
2XX 0 HW-C01
3 0 X O HW-C01
4 O 0 X HW-C10
310
1 0 X O HW-C01
Knob/Lever
Key
IlluminatedKnob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
2 O 0 X HW-C10
3 0 X O HW-C01
4 0 0 X HW-C10
1. Eachoperatorsub-assemblyisavailableasa“-1”anda“-2”for3-positionselectorswitches.Theinternalcamofa“-1”isdifferentfromthatofa“-2”.Thisresultsindesignatedcombinationsofopen
andclosedcontactsinthevariousoperatorpositions.
2. N/D=Nocircuitnumberdesignationrequiredinassembledpartnumber.
3. X=On(closedcontacts)O=Off(opencontacts).XXOverlappingcontactsremainon(closed)whenswitchismovedbetweenthesetwopositions.

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
637
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Contact Arrangement Chart: 3-Position Selector Switches
Style
Mounting
Position
Operator Position
Contact Block
Part Number Description
Operator Part Number
Contact Circuit
Number
Maintained Spring Return
from Right
Spring Return
from Left Two-Way
LCRL
C
RL
C
RL
C
RL
C
R
4NO
N/D
1 X 0 0 HW-C10
Knob/Lever
Key
IlluminatedKnob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
2 0 0 X HW-C10
3 X 0 0 HW-C10
4 0 0 X HW-C10
305
1 X 0 X HW-C10
Knob/Lever
Key
IlluminatedKnob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
2 0 0 X HW-C10
3 X 0 X HW-C10
4 0 0 X HW-C10
4NC
N/D
1 0 XX HW-C01
Knob/Lever
Key
IlluminatedKnob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
2XX 0 HW-C01
3 0 XX HW-C01
4XX O HW-C01
314
1 0 X O HW-C01
Knob/Lever
Key
IlluminatedKnob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
2XX 0 HW-C01
3 0 X O HW-C01
4XX 0 HW-C01
1. Eachoperatorsub-assemblyisavailableasa“-1”anda“-2”for3-positionselectorswitches.Theinternalcamofa“-1”isdifferentfromthatofa“-2”.Thisresultsindesignatedcombinationsofopen
andclosedcontactsinthevariousoperatorpositions.
2. N/D=Nocircuitnumberdesignationrequiredinassembledpartnumber.
3. X=On(closedcontacts)O=Off(opencontacts).XXOverlappingcontactsremainon(closed)whenswitchismovedbetweenthesetwopositions.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
638 www.IDEC.com
Custom Selector Switch Building Guide
Tobuildacustomselectorswitch,followthesesteps.
Step 1
Howmanypositionsoftheswitchareneeded?
# of positions
(2, 3, 4, 5)
Step 2
Howmanycontactsshouldtherebe?
# of isolated contacts
(maximum 6)
Step 3
FillintheTruthTable
(X=closed,0=open)
Knob Position
12345
Contacts
1
2
3
4
5
6
Step 4
Ifbuildinga2positionselector,skipthisstep.(2positionselectorshaveonlyonecam)
Ifbuildinga3,4,or5positionselector,determineappropriatecamasfollows:
• LookatRow1fromabovetableandlocateanidenticalrowintheoperatortruthtables(Seenextpage).
• Repeatforallrows.Theusermustndoneoperatorthatcontainsallrowsfromabovetable.
• Recordtheoperatorcamversion.
Step 5
Buildbyplacingappropriatecontactinappropriatemountingpositionforeachdesiredrowonoperatorcamtruthtable.“L”and“R”refertomountingonleftorright
sideofoperatorasviewedfromthefrontofthepanel.
Step 6
Developanassemblypartnumber(ifnecessary)asfollows:followstandardnumberingnomenclatureforselectorswitches(seepages627or631.Inplaceofthe
“CircuitNumber”indicatethecamnumberandcontactarrangementassuchASW322-3-OELCSS,where“3”isthecamnumber,andcontactarrangement“OELCXX”
callsoutindividualcontactmountinglocationsinorder(seediagramabove).O=NO,C=NC,E=NO-EM,L=NC-LB,X=nocontact.Partnumbermustdesignateall6pos-
siblemountinglocations.
Caution:Beforeputtinganycustomselectorswitchintouse,theusershoulduseanohmmetertotestfordesiredperformance.
1. ForOperatorTruthTables,seenextpage.
2
3
4
LR
1
Mounting Positions

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
639
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Operator Truth Tables
Usethefollowingtablestobuildcustomselectorswitches.
2 Position Selector Switches
Contact Mounting
Position
Operator
Position
Left Right
ASW200
ASLW200
ASW2K00
HW-C10
(NO)
L O X
RO X
HW-C01
(NC)
L X O
RX O
HW-C10R
(NO-EM)
LOX
ROX
HW-C01R
(NC-LB)
LXO
RXO
3 Position Selector Switches
Contact Mounting
Position
Operator Position
Left Center Right
ASW300-1
ASW3K00-1
ASLW300-1
HW-C10
(NO)
L X O O
RO O X
HW-C01
(NC)
L O XX
RXX O
HW-C10R
(NO-EM)
LXO O
ROOX
HW-C01R
(NC-LB)
LOX X
RXX O
Contact Mounting
Position
Operator Position
Left Center Right
ASW300-2
ASW3K00-2
ASLW300-2
HW-C10
(NO)
L X O X
RO O X
HW-C01
(NC)
L O X O
RXX O
HW-C10R
(NO-EM)
LXOX
ROOX
HW-C01R
(NC-LB)
LOX O
RXX O
Contact Mounting
Position
Operator Position
Left Center Right
ASW300-3
ASW3K00-3
ASLW300-3
HW-C10
(NO)
L X O O
RO O X
HW-C01
(NC)
L O X O
ROXO
HW-C10R
(NO-EM)
L X O X
RXOX
HW-C01R
(NC-LB)
L O XX
RXX O
4 Position Selector Switches
Contact Mounting
Position
Operator Position
1234
ASW400
HW-C10
(NO)
L X O O O
RO X O O
HW-C01
(NC)
L O XX X
RX O XX
HW-C10R
(NO-EM)
LXOOO
ROX O O
HW-C01R
(NC-LB)
LOXXX
RXOX X
Contact Mounting
Position
Operator Position
1234
ASW400-1
HW-C10
(NO)
L X O O O
RO O O X
HW-C01
(NC)
L O O X O
RO X O O
HW-C10R
(NO-EM)
L X X O X
RX O X X
HW-C01R
(NC-LB)
L O XX X
RXX X O
5 Position Selector Switches
Contact Mounting
Position
Operator Position
12345
ASW500
HW-C10
(NO)
L X O O O O
RO X O O O
HW-C01
(NC)
L O O X X X
RO O O X X
HW-C10R
(NO-EM)
LXOOOO
ROX O O O
HW-C01R
(NC-LB)
LOXXXX
RXOXXX
Contact Mounting
Position
Operator Position
12345
ASW500-1
HW-C10
(NO)
L X O O O O
ROOOOX
HW-C01
(NC)
L O O O X O
RO X O O O
HW-C10R
(NO-EM)
LXX X O X
RX O XX X
HW-C01R
(NC-LB)
L O XXXX
RXX X X O

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
640 www.IDEC.com
Nameplates — TW Series
Faceplates
NWAL NWAQL NWAS EMERGENCY STOP
1.13" (29mm)
1.0"
(25.4mm)
1.13" (29mm)
0.975"
(25mm)
0.566"
(14.5mm)
1.76" (45mm)
1.76" (45mm)
ø70mm
Part Number
Nameplate
(blank)
NWAL-OB(black)
NWAL-OR(red)
NWAQL-OB(black)
NWAQL-OR(red) NWAS-OB NWAR-O
Nameplate
(engraved) NWAL-jNWAQL-jNWAS-jNWAR-27†
1. Inplaceofj,inserteithertheStandardLegendCodefromtablebeloworcustomengravingdelimitedby““.
2. Standardengravingsareavailableatnocharge.
3 NWAR-27comesmarked“EmergencyStop”asshownindrawing.
Standard Legend Codes
Pushbuttons Pushbuttons/Selector Switches Selector Switches
Legend Code Legend Code Legend Code Legend Code Legend Code
AUTO
CLOSE
DOWN
EMERG.STOP
FAST
FORWARD
HAND
HIGH
IN
INCH
JOG
LOW
LOWER
OFF
ON
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
OPEN
OUT
RAISE
RESET
REVERSE
RUN
SLOW
START
STOP
STOP
TEST
UP
I(Int’lOn)
O(Int’lOff)
EMO
116
117
118
119
120
121
122
123
124
125
126
127
150
151
152
AUTO-MAN
CLOSE-OPEN
DOWN-UP
FAST-SLOW
FOR-REV
HAND-AUTO
HIGH-LOW
JOG-RUN
LEFT-RIGHT
LOWER-RAISE
MAN-AUTO
OFF-ON
ON-OFF
OPEN-CLOSE
RAISE-LOWER
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
REV-FOR
RUN-JOG
RUN-SAFE
SAFE-RUN
SLOW-FAST
START-STOP
STOP-START
UP-DOWN
216
217
218
219
220
221
222
223
AUTO-MAN-OFF
AUTO-OFF-MAN
CLOSE-OFF-OPEN
DOWN-OFF-SLOW
FAST-OFF-SLOW
FOR-OFF-REV
LEFT-OFF-RIGHT
LOWER-OFF-RAISE
OFF-MAN-AUTO
OFF-SLOW-FAST
OFF-1-2
OPEN-OFF-CLOSE
SLOW-OFF-FAST
SUMMER-OFF-WINTER
UP-OFF-DOWN
1-OFF-2
HAND-OFF-AUTO
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
1. Toorderengravednameplates,addlegendcodetonameplatepartnumber.
Characterheightbasedonthenumberofcharactersandsizeofnameplate.Standardcharactersizeis3/16”.
2. Nameplateswithstandardlegendsarethesamelistpriceasblanknameplates.
Nameplate Order Form on next page.

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
641
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Custom Engraved Nameplates Order Form — TW Series
CopythisorderformanduseittospecifyLetterHeight,CustomEngravings,LocationofEngravingonNameplate,andQuantityDesired.
Toensureengravingaccuracy,faxittoyourIDECrepresentative.orDistributor.
YourCompanyName: _________________________________________
YourName: _________________________________________
Telephone: _________________________________________
Fax&Email: _________________________________________
IDECRep/DistributorContact:_________________________________
POnumber(ifknown):_________________________________
IDECRep/DistributorPhone:_________________________________
IDECRep/DistributorFax&Email:_________________________________
NWAL
Engraving
Location
Step 1.
ChooseLetterSize-7/64”or1/8”.
Checktheboxforthelettersizeyou
want.Thenwriteyourletteringinbox
belowcheckboxes.Note:1/8”size
letterscannotexceed9characters.
Step 2.
SpecifyQuantity.
Qty
Enterthenumberof
nameplatesdesired
intheboxontheright.
7/64”
LetterSize
11charactersmax
(for7/64”sizeletters)
Sample Letter Sizes
7/64”Letters:
1/8”Letters:
1/8”
LetterSize
9charactersmax
(for1/8”sizeletters)
1 2 3 4 5 6 7 8 9 10 11
NWAQL
Engraving
Location
Step 1.
ChooseLetterSize-7/64”or1/8”.
Checktheboxforthelettersizeyou
want.Thenwriteyourletteringinbox
belowcheckboxes.Note:1/8”size
letterscannotexceed9characters.
Step 2.
SpecifyQuantity.
Qty
Enterthenumberof
nameplatesdesired
intheboxontheright.
7/64”
LetterSize
11charactersmax
(for7/64”sizeletters)
Sample Letter Sizes
7/64”Letters:
1/8”Letters:
1/8”
LetterSize
9charactersmax
(for1/8”sizeletters)
1 2 3 4 5 6 7 8 9 10 11
NWAS
Engraving Location A
Engraving Location B
Step 1.
ChooseLetterSize-1/8”or
3/32”.
Checktheboxfortheletter
sizeyouwant.Thenwrite
yourletteringinboxbelow
checkboxes.Note:1/8”size
letterscannotexceed14
characters.
3/32”
LetterSize
20charactersmax
(for3/32”sizeletters)
1/8”
LetterSize
14charactersmax
(for1/8”sizeletters)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Step 2.
SpecifyQuantity.
Qty
Enterthenumberof
nameplatesdesired
intheboxontheright.
Step 3.
SpecifyLocation.
Location
Enterthelocationof
engraving(AorB),in
theboxontheright.
Sample Letter Sizes
3/32”Letters:
1/8”Letters:

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
642 www.IDEC.com
Switch Engraving Order Form – TW Series
CopythisorderformanduseittospecifyLetterHeight,MaximumNumberofLinesandTexttobeengraved.
Toensureengravingaccuracy,faxittoyourIDECrepresentativeorDistributor.
YourCompany: Telephone:
Name: Fax:
Address: Email:
PO: PartNumbertobeEngraved:
Pleasecheckoneoftheboxesbelowtoindicateyourchoiceofengravingoptions:
Square
Switch Round
Switch
ø29mm, ø40mm Mushroom Head
Engraving
Area 1
Engraving
Area 2†
# of Lines Letter
Height
Max. Characters
Per Line
# of
Lines
Letter
Height
Max. Characters
Per Line
# of
Lines
Letter
Height
Max. Characters
Per Line
1
5/32 6
1
5/32 5 Engraving
Area 1 1
5/32 5
1/8 6 1/8 6 1/8 5
2
5/32 6
2
5/32 5 Engraving
Area 2 1
5/32 7
1/8 5 1/8 6 1/8 7
3 1/8 6 3 1/8 5
4 3/32 5 4 3/32 5
1. Abovementionedspecicationsholdtrueforstandardsizepushbuttons(roundandsquare).
2. †EngravingArea2canbeengravedfor40mmmushroomHeadnon-Illuminatedpushbuttononly.
3. Engravingisdoneonthebuttonitselffornon-Illuminatedpushbuttonsandonmarkingplateforilluminatedpushbuttonsandpilotlights.
4. Pleaseentertextexactlyhowyouwantitengraved,takecaretoemphasizecapitalorsmallletters.
Entertexttobeengraved:
Line1:
Line2:
Line3:
Line4:
Sample Letter Sizes
1/8Letters:
5/32Letters:
ForIDECInternalUseOnly:
WorkOrder#:

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
643
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Accessories
TW Series Accessories
Item Appearance Description/Usage Part Number
LampRemovalTool RubbertoolusedtoinstallorremoveLED’sandincandescentlamps OR-55
ContactBlockRemover Usedtoremovecontactblocks,transformers,lenses,andadaptors.Canalsobeusedto
determinepanelthicknessadjustment. TW-KC1
NutLockingWrench UsedinOR-14lockingwrenchtotightenlockingnutsinsidesquarebezel TW-KQ2
MetalBezel
Chromeplatedbezels
tightenontooperator
(replacementfor
damagedbezels)
Standardoctagonalunits(chrome-pl.) AW-R8
Fullshroudoctagonalunits(chrome-pl.) AW-RF8
FullshroudmushroomheadunitsØ40mm AW-G4
PlasticBezel
Blackplasticbezelsfor
squarebuttons
(replacementfor
damagedbezels)
Roundushunits(blackplastic) AW-RP1B
Roundextendedunits(blackplastic) AW-FP1B
Squareunits(blackplastic) AW-Q1B
Squareunitswithfullshroud(blackplastic) AW-QF1B
Boot/Cover Usedtocoverandprotect
pushbuttons
Waterprooflenscoverforsquarepilotlights APW00LN
Waterprooflenscoverforsquareilluminatedbuttons APW00L
Clearbootforroundushunits OC-31
Clearbootforroundextendedunits OC-32
*Inplaceofasterisk,specifyRubber Boot color:
B(black),G(green),R (red),Y (yellow)-(nitrilrubber) OCW-11*
Anti-RotationRing Ringtopreventoperatorbasefromrotatinginthemountinghole.
Usedwhennameplateisnotused OGL-31
MountingHolePlug Blackrubberplugllsunusedmountingholesinpanel. OB-31
MetallicMountingHole
Plug
Forpluggingunusedmountingholesinthepanel.Tightentheattachedlockingringtoatorqueof
12kfg-cmmaximum
Degreeofprotection:IP66
LW9Z-BM
ReplacementKeys Pairofkeys(#0) TW-SK
ReplacementBlack
SleeveforKeyswitch AKW2B-B
MetalButtonGuard Usedonushbuttonstopreventinadvertentactuation OLW-C

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
644 www.IDEC.com
Item Appearance Description/Usage Part Number
TerminalTabAdaptor Quick-connectterminals #250(17/64”x3/64”)singletab TW-FA1
Lock-outAdaptor
Usedtoprovidelock-outprotectionforpushbuttonsandknobselectorswitches:
•UptoØ40mmmushroomheadsize
(Padlocknotincluded.)
Notapplicablefore-stops.
HW9Z-KL1
TWtoTWTDAdaptor UsedtomountTWseriescontrolunit(exceptsquareunits)Ø7/8”(22mm)intoaØ1-13/64”
(30mm)panelcut-out. TWN-A1R8
ReplacementMarking
Plates
Whiteplasticengravingplate
foruseonallilluminatedunits
(includedineachlens).
Maybeusedtocapture
printedmylarinsert(notsup-
pliedbyIDEC)underlensface.
RoundPushbutton(Ø14mm) ALW2B
RoundPilotLight(Ø14mm) APW2B
MushroomPushbutton(Ø14mm) ALW3B
SquarePilotLight(q21mm) APQW1B
SquarePushbutton(q21mm) ALQW2B
Fingersafe Covers for TW Series
Appearance Description Used with Part Number
Fingersafeterminalcover,adds6mmtooveralldepth APWandUPQWfullvoltagepilotlights APS-PVL
Fingersafeterminalcover,adds3.5mmtooverall
depth.Onerequiredforeachcontact,onlyforrear-
mostterminals
Non-illuminatedpushbuttonsandselectors HW-VL2
Fingersafeterminalcover,adds3mmtooveralldepth APWandUPQWtransformerpilotlights,andillumi-
natedpushbuttonsandilluminatedselectors HW-VL3
Fingersafeterminalcoverforcontacts. Fullvoltageilluminatedpushbuttonsandselectors HW-VL4
Fingersafeterminalcoverforfullvoltageadaptor,adds
3mmtodepth Fullvoltageilluminatedpushbuttonsandselectors HW-VL5
Fingersafeterminalcoverforhalfsizetransformer
adaptor,adds3mmtodepth Illuminatedpushbuttonsandselectors HW-VL6

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
645
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Dimensions
Pushbuttons
Flush Extended Extended with Full Shroud
30
37
ø29
ø24
13
M3.5 Terminal
Screws
68.5 (3-4 blocks)
48.5 (1-2 blocks)
Panel Thickness 1 to 6
13
19 30
37
ø29
ø24
M3.5 Terminal
Screws
68.5 (3-4 blocks)
48.5 (1-2 blocks)
Panel Thickness 1 to 6
ø29
30
37
ø24
19.5
M3.5 Terminal
Screws
68.5 (3-4 blocks)
48.5 (1-2 blocks)
Panel Thickness 1 to 6
29mm Mushroom 40mm Mushroom Mushroom with Full Shroud
M3.5 Terminal
Screws
13
22.5
68.5 (3-4 blocks)
48.5 (1-2 block)
Panel Thickness 1 to 6
30
37
ø29
M3.5 Terminal
Screws
13
22.5
ø40
68.5 (3-4 blocks)
48.5 (1-2 blocks)
Panel Thickness 1 to 6
30
37
M3.5 Terminal
Screw
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness 1 to 6
30
37
ø46
23
29mm Push-Lock-Turn-Reset 40mm Push-Lock-Turn-Reset Keylock Push On/Off
30
37
13
22.5
ø29
M3.5 Terminal
Screws
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness
1 to 6 Reset Angle 75°
M3.5 Terminal
Screws
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness
1 to 6 Reset Angle 75°
30
37
13
22.5
ø40
Reset
(unlock)
37
25
47
13
ø29
45°
30
M3.5 Terminal
Screws
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness
1 to 6
40mm Pushlock Key reset 40mm Push-Pull Square Flush
(unlock)
Reset
37
25
47
13
45°
30
ø40
M3.5 Terminal
Screws
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness
1 to 6
37
25
13
30
ø40
30.5
M3.5 Terminal
Screws
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness
1 to 6
37
13
30
30
25
M3.5 Terminal
Screws
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness
1 to 6
Square Extended
37
13
30
30
20
25
M3.5 Terminal
Screws
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness
1 to 6
Selector Switches
37
25
13
30
ø24
ø29
M3.5 Terminal
Screws
48.5 (2 blocks)
68.5 (4 blocks)
Panel Thickness 1 to 6
M3.5 Terminal
Screws
48.5 (2 blocks)
68.5
(
4 blocks
)
Panel Thickness 1 to 6
37
13
30
ø29
ø25
25
M3.5 Teminal
Screws
48.5 (2 blocks)
68.5 (4 blocks)
Panel Thickness 1 to 6
37
13
30
ø29
19
41
ø24

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
646 www.IDEC.com
Dimensions continued
Illuminated Pushbuttons
Extended Extended with Full Shroud Square Extended
Marking plate: ø15.5mm
Panel Thickness
1 to 6
13
19 30
ø24
ø29
37
Marking plate: ø15.5mm
Panel Thickness
1 to 6
30
ø24
ø29
37
20 30
37
20
13
25
30
Marking plate: 21mm
Panel Thickness
1 to 6
29mm Push-Turn-Reset 40mm Push-Turn-Reset Mushroom
Marking plate: ø13.9mm
Reset Angle: 75°
Panel Thickness
1 to 6
30
37
13
22.5
ø29
Marking plate: ø13.9mm
Reset Angle 75°
30
37
13
22.5
ø40
Panel Thickness
1 to 6
Marking plate: ø13.9mm
30
37
13
ø29
22.5
Panel Thickness
1 to 6
Push-Pull
Marking plate: ø13.9mm
Panel Thickness
1 to 6
30
37
25
13
ø40
30.5
Illuminated Selector Switches
1 Contact Block with Full Voltage Adaptor Transformer (2 blocks) 1 Contact Block with Half Size Transformer
X2 X1
X2
X1
M3.5 Terminal Screws Panel Thickness
1 to 6
86.5
X2
X1
64.5
Panel Thickness
1 to 6
2 Contact Blocks with Full Voltage Adaptor Transformer (4 blocks) 2 Contact Blocks with Half Size Transformer
X1
X2
63.5
M3.5
Terminal Screw Panel Thickness
1 to 6mm
X2
X1
106.5
M3.5 Terminal Screws Panel Thickness
1 to 6
X2
X1
68.5
Panel Thickness
1 to 6
3 Contact Blocks with Full Voltage Adaptor 4 Contact Blocks with Full Voltage Adaptor 3 Contact Blocks with Half Size Transformer
X2 X1
68.5
M3.5
Terminal Screws Panel Thickness
1 to 6
X1
X2
X2
X1
84.5
M3.5 Terminal Screws
Panel Thickness
1 to 6

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
647
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Dimensions continued
Pilot Lights
Round Flush APW1 Full Voltage Round Flush APW1 Transformer
28.5 13 30
ø29
37
ø24
17
Panel Thickness
1 to 6
28.5 13
66.5
30
ø29
37
ø24
17
M3.5 Terminal Screw
Panel Thickness
1 to 6
Round Flush Marking Type APW1B Full Voltage Round Flush Marking Type APW1B Transformer
Marking plate: ø15.5 mm
28.5 13 30
ø29
37
ø24
17
Panel Thickness
1 to 6
Marking plate: ø15.5 mm
28.5 13
66.5
30
ø29
37
ø24
17
M3.5 Terminal
Screw
Panel Thickness
1 to 6
Dome APW2 Full Voltage Dome APW2 Transformer
Panel Thickness
1 to 6
28.5 13
25
30
ø23.6
ø29
37
M3.5 Terminal
Screw
Panel Thickness
1 to 6
28.5 13
66.5 25
30
ø23.6
ø29
37
Square Flush Marking Type APQW1B Full Voltage Square Flush Marking Type APQW1B Transformer
Marking plate: 22 mm
Panel Thickness
1 to 6
28.5 13 30
37
16
25
30
Marking plate: 22 mm
M3.5 Terminal
Screw Panel Thickness 1 to 6
28.5 13
66.5
30
37
16
25
30
Illuminated Selector Switches
M3.5 Terminal Screws
83.5 (4 blocks)
B: 86.5 (2 blocks), 106.5 (4 blocks)
A: 63.5 (2 blocks)
Panel Thickness 1 to 6
13
25
ø24
ø29
30
37

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
648 www.IDEC.com
Dimensions continued
Panel Cut-Out
Diagram Part Dimension
A B C D
A
B
D
C
Pushbuttons
Ø0.137”
(3.5mm)
1.95”(50mm);
1.76”(45mm)
minimum
Ø0.878”
(22.3mm)
1.17”(30mm)
Std.Octagonal
>1.56”(40mm)
LargeMushroom
Pilot Light
Illuminated Pushbuttons
Selector Switches 1.17”(30mm)
*Seenote.
Illuminated Selector Switches
1.TheØ0.137”(Ø3.5mm)recessisnecessarywheneitherthenameplateoranti-rotationringisused.
2.*>1.404”(36mm)for2-or3-position.
>1.95”(50mm)for4-or5-position.
Accessory Dimensions
OGL-31
Anti-Rotation Ring
OLW-C
Metal Button Guard
OCW-11
Pushbutton Rubber Boot
OB-31
Mounting Hole Rubber Plug
ø22 ø27.4
10.2
0.8
ø22.5
18.6
1.6t
R42.5
Mounting Centers
50 min.
15
Flush
M22 P1.0
ø31
18.5
ø32
9
Extended
M22
Button
installed
Button
installed
P1.0
ø32
9
ø26
ø31
21
ø29
ø25
3.5
3.5
HW9Z-KL1
Lock-out Adaptor
AW-RP1B
Round Plastic Bezel
AW-FP1B
Round Plastic w/Full Shroud
Key hole ø8
Waterproof Rubber
Gasket 0.5t
30
70
ø50
(ID: ø44.4)
93
29.5
30
R66.5
Panel Thickness
0.8 to 3.2
82.5
ø22.2
24 (inside)
ø29
13
ø29
19.8
AW-QF1B
Square Full Shroud
30
13
Finger-Safe Cover Dimensions
HW-VL6 HW-VL5 HW-VL4
HW-VL3 HW-VL2 APS-PVL

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
649
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Component Construction and General Instructions — TW Series
Instructions for Switches and Pilot Devices
TWSeries:AdjustmentforPanelThickness
Thepanelthicknessringprovidesadjustmentfrom0.04”to0.24”(1to6mm)
in0.004”(0.1mm)increments.Rotatetheringuntilthemarkingsaroundthe
peripheryarealignedforthedesiredthickness,asshownbelow.
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0
Scale on Adjustment (in 0.1 mm)
0.1 mm
12
4
6
3
5
1 mm Panel Thickness Scale
(in 1 mm on the operator)
A
3
543
54
6 6
2
Ex. Panel thickness 2 mm Ex. Panel thickness 2.6 mm
Note: Whenanameplate
orananti-rotationring
isused,add0.03”
(0.8mm)tothepanel
thicknessdimension.
Anadjustmentforpanelthicknessesshownbelowcanbemadequicklybyusing
thecontactblockremovertool.
1.6 mm
2.3 mm
3.5 mm
1 mm 2 mm
3.2 mm
Tool TW-KC1

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - TW Series Switches & Pilot Devices
650 www.IDEC.com
Instructions continued
Pilot Lights and Pushbuttons
IMPORTANT:InstallthebodyoftheTWcontrolunitwiththepanelthicknessscalefacingup.
Octagonal and Round Bezels
Octagonalandroundbezelsscrewintotheoperator.Usealockingringwrench(optional)forsecuretighteningandeasyremoval.Roundushandextendedbuttons
snapontotheoperatorbase.Mushroombuttonsscrewontotheoperatorbase.
Everyroundlenscanbeusedwithorwithoutlegendmarkings.Engravingcanbedoneonawhitetranslucentplatewhichisplacedinthelens,orclearmylarcanbe
printedandplacedinthelens.
Round
Marking
Unit
Insertmarking
plateunderlens
Lens
Marking
Plate
Press in
Pressinroundushand
extendedlens.
Screwinmushroomlens
Square Bezels
Squarebezelsareinstalledina3-stepprocedure.Firstinstallthebaseplatefromthefront.Theninstallthelocknutusingthenutlockingwrench(optional).Finally,
installthesquarebezel,whichsnap-tsontothebaseplate.Squarebuttonsalsosnapontotheoperatorbase.
Everysquarelenscanbeusedwithorwithoutlegendmarkings.Engravingcanbedoneonawhitetranslucentplatewhichisplacedinthelens,orclearmylarcanbe
printedandplacedinthelens.Squareunitsincludearoundwaterprooflenswhichscrewsintotheoperator.Thesquareouterlenssnapson.
Square
Marking
Units
Insertmarking
plateunderlens
PilotLight
Marking Plate
Insert
Square Lens
Insertmarking
plateunderlens
IlluminatedPushbutton
Marking Plate
Lens Retainer
Waterproof Lens
Press in
Square Lens
Toremovesquarelensfromoperator,placeascrewdriverundertheindentationonthesideofthelens.Toremovethemarkingplate,placeascrewdriverunderthe
indentationandliftouttheplate.Thelensretainercanberemovedbypressinga3/16”screwdriverintooneoftherecesses.
Marking Plate Engraving Area
Shape Engraving Area Used With Part Number
Round Ø0.55”(14mm) Illuminatedpushbuttons ALW2B
Ø0.55”(14mm) Pilotlights APW2B
Mushroom Ø0.55”(14mm) Illuminatedmushroom ALW3B
Square q0.83”(21mm) Squarepilotlights APQW1B
Square q0.83”(21mm) Squareilluminatedpushbuttons ALQW2B

Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
651
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
Instructions, continued
Selector Switches
Theoperatorshaftofeachunithasarecesstoidentifyinwhichdirectiontoinstallthehandle.Alignthehandlewiththerecess.Presscolorinsert(TW-HC1)intothe
handleandthenpresshandleintotheoperator,asshownbelow.
Selector Switch
(non-illuminated)
Illuminated
Selector Switch
Recess
Pressin
colorinsert
Pressin
handle
Removecolorinsertbeforepullingoutthehandle.
Standard Operating Positions
2-Postion, 90º 3-Postion, 45º 4-Postion, 45º 5-Postion, 30º
1 2
1 2
0
1
2
3
4
1
2
3
4
5
Positions: Non-Illuminated 3-Position Operators
12
0
1
2
0
1
2
0
Installation
TerminalX1=Positive
TerminalX2=Negative
Makesureslot
isfacingup
Lampholderisinstalledasshown,
duetopolarity.
Leadholder(usedwithtwostacksof
contactblocks)doesnothavepolarity.
TWIlluminatedPushbuttons,
TWSelectorSwitches
(ACTransformerorFullVoltage)
TW Pilot Lights
Installation of LED Illuminated Units
ACtransformersarerecommendedforuseinareassubjectedtoinductivenoise.Whenusingfullvoltagetypes,installaprotectiondiodeasshownbelow.(Diode
withDCpowersupplytoprotectagainstsurgesandnoise.)
Te rminal
X1
Terminal
X2
Diode
LED
MakesurethatLEDilluminatedunitsareinstalledwithcorrectpolarity,asindicatedattheterminals.