6 1110XI_Copy Of 455221 Product Data Sheet

2018-06-08

: Pdf 455221 Product Data Sheet 455221 Product Data Sheet Forms

Open the PDF directly: View PDF PDF.
Page Count: 2

Architectural Coatings SPEEDHIDE Interior Wall and Trim Semi-Gloss Oil
GENERAL DESCRIPTION
PRODUCT DATA
SPEEDHIDE®6-1110XI Series
RECOMMENDED SUBSTRATES
FEATURES / BENEFITS
Our best professional interior semi-gloss alkyd formulated to
meet the performance requirements of professional applicators.
SPEEDHIDE Interior Semi-Gloss Oil provides excellent hiding,
touchup, stain removal and scrubbability properties. SPEEDHIDE
Interior Semi-Gloss Oil is an alkyd with excellent flow and level-
ing to yield a smooth, even appearance on interior walls and trim
surfaces. Recommended for interior use on properly prepared
and primed or previously painted drywall, plaster, masonry, wood,
and metal surfaces.
PRODUCT TYPE: Alkyd
SHEEN: Semi-Gloss: 50 to 70 (60º Gloss Meter)
VOLUME SOLIDS*: 52% +/- 2%
WEIGHT SOLIDS*: 70% +/- 2%
VOC*: 374 g/L (3.1 lbs./gal.)
WEIGHT/GALLON*: 10.4 lbs. (4.7 kg) +/- 0.2 lbs. (91 g)
*Product data calculated on product 6-1110XI.
COVERAGE: Approximately 400 sq. ft./gal. (37.2 sq. m/3.78L) per
U.S. Gallon (3.78L) on smooth, nonporous surfaces.
Wet Film Thickness: 4 mils
Wet Microns: 102
Dry Film Thickness: 2.1 mils
Dry Microns: 53
Coverage figures do not include loss due to surface irregularities and
porosity or material loss due to application method or mixing.
DRYING TIME: Dry time @ 77ºF (25ºC); 50% relative humidity.
To Touch: 5 hours
To Recoat: 24 hours
To Full Cure: 7 to 14 days
Drying times listed may vary depending on temperature, humidity, film
build, color, and air movement.
CLEANUP: High quality paint thinner
DANGER: Rags, steel wool or waste soaked with this product may
spontaneously catch fire if improperly discarded. Immediately after
use, place rags, steel wool or waste in a sealed water-filled metal
container. Refer to www.ppgpittsburghpaints.com, Spontaneous
Combustion Advisory for additional information.
DISPOSAL: Contact your local environmental regulatory agency for
guidance on disposal of unused product. Do not pour down a drain or
storm sewer.
FLASH POINT: 116ºF (46.7ºC)
TINTING AND BASE INFORMATION
Refer to the appropriate color formula book, automatic tinting
equipment, and or computer color matching system for color formulas
and tinting instructions.
6-1110XI White and Pastel Base
6-1160XI Midtone Base*
6-1300XI Neutral Base*
*Must be tinted before use.
Some colors, drastic color changes, or porous substrates may require
more than one coat to achieve a uniform finish.
A3.66
APPLICATION INFORMATION
Stir thoroughly before and occasionally during use. When using
more than one can of the same color, intermix to ensure color
uniformity. USE WITH ADEQUATE VENTILATION. KEEP OUT
OF REACH OF CHILDREN. Read all label and Material Safety
Data Sheet (MSDS) information prior to use. MSDS are available
through our website or by calling 1-800-441-9695.
Application Equipment: Apply with a high quality brush, roller,
paint pad, or by spray equipment. Where necessary, apply a sec-
ond coat.
Airless Spray: Pressure 2000 psi, tip 0.017” - 0.021”
Spray equipment must be handled with due care and in
accordance with manufacturer’s recommendation. High-pressure
injection of coatings into the skin by airless equipment may cause
serious injury.
Explosion-proof equipment must be used when coating with these
materials in confined areas. Keep containers closed and away
from heat, sparks, and flames when not in use.
Brush: High quality natural bristle brush
Roller: 3/16” - 3/8” nap roller cover
Thinning: Do not thin.
Permissible temperatures during application:
Material: 50 to 90ºF 10 to 32ºC
Ambient: 50 to 90ºF 10 to 32ºC
Substrate: 50 to 90ºF 10 to 32ºC
Features Benefits
Excellent adhesion Sticks to difficult substrates
Excellent block resistance Tack free film/ideal for doors, doorframes, and windowsills
Excellent flow and leveling Less brush marks on the paint film/better coverage on trim
Alkyd hardness and durability Resists chipping providing long lasting beauty
Good color and gloss retention Looks like new longer
Excellent scrubbability Withstands repeated cleaning requirements
Good hiding power and coverage Hides surface imperfections
Meets MPI Category #47, Interior Alkyd Meets strict performance and aesthetic requirements
Semi-Gloss, Gloss Level 5
CONFORMANCE STANDARDS
VOC compliant - lower than Federal AIM
Meets MPI®Category #47, Interior Alkyd Semi-Gloss, Gloss
Level 5
Aluminum Gypsum Wallboard-Drywall
Concrete Masonry
Ferrous Metal Plaster
Galvanized Steel Wood
SPEEDHIDE® 6-1110XI Series
Architectural Coatings SPEEDHIDE Interior Wall and Trim Semi-Gloss Oil
GENERAL SURFACE PREPARATION
Surfaces to be coated must be dry, clean, sound, and free from all contamination including loose and peeling paint, dirt, grease, oil, wax,
concrete curing agents and bond breakers, chalk, efflorescence, mildew, rust, product fines, and dust. Remove loose paint, chalk, and
efflorescence by wire brushing, scraping, sanding, and/or pressure washing. Putty all nail holes and caulk all cracks and open seams. Sand
all glossy, rough, and patched surfaces. Feather back all rough edges to sound surface by sanding. Prime all bare and porous substrates
with an appropriate primer.
WARNING! If you scrape, sand, or remove old paint, you may release lead dust or fumes. LEAD IS TOXIC. EXPOSURE TO LEAD DUST
OR FUMES CAN CAUSE SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT WOMEN SHOULD
ALSO AVOID EXPOSURE. Wear a properly fitted NIOSH-approved respirator and prevent skin contact to control lead exposure. Clean up
carefully with a HEPA vacuum and a wet mop. Before you start, find out how to protect yourself and your family by contacting the USEPA
National Lead Information Hotline at 1-800-424-LEAD or log on to www.epa.gov/lead. In Canada contact a regional Health Canada office.
Follow these instructions to control exposure to other hazardous substances that may be released during surface preparation.
ALUMINUM: This substrate may present potential adhesion problems. Any coating applied directly to aluminum should be spot applied,
allowed to cure overnight, and then evaluated for adhesion. If adhesion is good, the application may proceed.
CONCRETE and MASONRY: New concrete should cure for at least 30 days and preferably 90 days prior to priming and painting. The pH
of the substrate must be less than 10 before priming with an alkali resistant primer.
FERROUS METAL: The surface must be cleaned thoroughly to remove any dust, rust, and surface contaminants, and then primed.
GALVANIZED STEEL: Caution must be used when selecting coatings for use on all galvanized metal surfaces. These substrates may have
a factory-applied stabilizer, which is used to prevent white rusting during storage and shipping. Such stabilizers must be removed by either
brush blasting, sanding or chemical treatment prior to priming with a primer approved for galvanized steel.
GYPSUM WALLBOARD-DRYWALL: Nails or screws should be countersunk, and they along with any indentations should be mudded flush
with the surface, sanded smooth and cleaned to remove any dust, then prime prior to painting the substrate.
PLASTER: Plaster, hardcoat, skim coat, or other alkaline surfaces should be allowed to cure for at least 30 days prior to priming with an
alkali resistant primer.
WOOD: Unpainted wood or wood in poor condition should be sanded smooth, wiped clean, then primed. Any knots or resinous areas must
be primed before painting. Countersink all nails, putty flush with surface, then prime.
A3.66 4/2013
(Supersedes 9/2012)
PACKAGING
RECOMMENDED PRIMERS
PPG Architectural Finishes, Inc. believes the technical data presented is currently accurate: however, no guarantee of accuracy, comprehensiveness, or performance is given or
implied. Improvements in coatings technology may cause future technical data to vary from what is in this bulletin. For complete, up-to-date technical information, visit our web
site or call 1-800-441-9695.
PPG Industries, Inc.
Architectural Coatings
One PPG Place
Pittsburgh, PA 15272
www.ppgpro.com
Technical Services
1-800-441-9695
1-888-807-5123 fax
PPG Canada, Inc.
Architectural Coatings
4 Kenview Blvd
Brampton, ON L6T 5E4
Architect/Specifier
1-888-PPG-IDEA
Aluminum 6-204, 17-921
Concrete 4-603, 17-921
Ferrous Metal 6-208, 90-712, 90-912
Galvanized Steel 6-209, 17-921
Gypsum Wallboard-Drywall 6-2, 6-4, 9-900, 12-900
Masonry 4-603, 17-921
Plaster 4-603, 17-921
Wood 6-9, 17-921, 12-900
1-Gallon (3.78L)
5-Gallon (18.9 L)
Not all products available in all sizes.
LIMITATIONS OF USE
Apply only when air, surface and product temperatures are between
50ºF (10ºC) and 90ºF (32ºC).
Not recommended for use on floors.
For exterior use on doors, trim, and other small areas of wood or
metal surfaces. Not for exterior use on large expanses of wood.
Important: All oil based alkyd products change color with age. The
yellow discoloration is most visible in whites and light colors. PPG
latex products are recommended when yellowing is a concern.
The PPG logo is a registered trademark of PPG Industries Ohio, Inc. SPEEDHIDE is a registered trademark of PPG Architectural Finishes, Inc. The Master Painters Institute
and MPI are registered trademarks of Master Painters Institute, Inc.

Navigation menu