09_Nov03_ Brochure
92810-Brochure 92810-Brochure 92810-Brochure 786680 Batch2_1 unilog cesco-content
51422-Brochure- 1 51422-Brochure-_1 51422-Brochure-_1 786680 Batch2_1 unilog cesco-content
2014-05-16
: Pdf 51422-Brochure 1 51422-Brochure_1 786680 Batch2_1 unilog
Open the PDF directly: View PDF .
Page Count: 146
Download | |
Open PDF In Browser | View PDF |
Transformers 9-1 November 2003 Transformers Vol. 1, Ref. No. [0301] Contents Description Page General Purpose Transformers Single-Phase, Types EP, DS-3, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Three-Phase, Types EPT, DT-3, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Three-Phase, Types EPT, DT-3, 50/60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrostatically Shielded Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Energy Efficient Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NEMA TP-1-1996 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Low Temperature Rise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Energy Efficient Harmonic MitigatingTransformers . . . . . . . . . . . . . . . . . . . K Factor Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drive Isolation Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mini-Power Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Totally Enclosed Non-Ventilated Transformers . . . . . . . . . . . . . . . . . . . . . . . Class I, Division 2, Groups C and D Transformers . . . . . . . . . . . . . . . . . . . . . Open Type Core and Coil Assembly Transformers. . . . . . . . . . . . . . . . . . . . . Filtered Noise Isolation Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Low Sound Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Marine Duty Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Buck-Boost Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Autotransformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Industrial Control Transformers Type MTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type MTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type MTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type MTK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CE Marked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type AP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Purpose and Industrial Control Transformers Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Price Modifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary of Transformer Terms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2 9-8 9-19 9-26 9-31 9-33 9-36 9-38 9-41 9-50 9-57 9-59 9-61 9-63 9-65 9-67 9-70 9-72 9-88 9-89 9-94 9-96 9-105 9-110 9-118 9-120 9-122 9-136 9-138 9-141 9-142 9-144 Dry-Type Transformer Family CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers General Purpose Transformers 9-2 November 2003 Single-Phase, Types EP, DS-3, 60 Hz Single-Phase, Types EP, DS-3, 60 Hz Vol. 1, Ref. No. [0302] Features, Benefits and Functions UL listed. 60 Hz operation. ■ Short-term overload capability as required by ANSI. ■ Meet NEMA ST-20 sound levels. ■ ■ Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-1. Insulation System Classification Standards and Certifications Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C Industry Standards Type EP 3-25 kVA 9 Product Description All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Type EP ■ ■ ■ ■ ■ ■ ■ Sand and Resin Encapsulated design. Suitable for indoor or outdoor applications. Totally enclosed, non-ventilated enclosures. Enclosures are NEMA 3R rated. Mountable in any position indoors and upright only outdoors. 185ºC Insulation System, 115ºC rise standard. Available in ratings through 37.5 kVA and 4160 volts primary. Type DS-3 ■ ■ ■ ■ ■ Ventilated, NEMA 2 enclosure standard. Suitable for indoor applications, outdoors when weathershields are also installed. Upright mounting only. 220ºC Insulation System, 150ºC rise standard. Available in single-phase ratings 15 – 167 kVA and up to 4160 volts primary. Application Description Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. Options and Accessories Please refer to Page 9-120. Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hertz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one hour; and 125% load for four hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. The basic purpose of a transformer is voltage transformation as near as practically possible to the load for economy and distribution of power. Typical loads for dry-type distribution transformers include lighting, heating, air conditioners, fans, and machine tools. Such loads are found in commercial, institutional, industrial, and residential structures. For more information visit: www.cutler-hammer.eaton.com The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Cutler-Hammer ventilated transformers, Type DS-3, utilize a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Cutler-Hammer encapsulated transformers, Type EP, utilize a NEMA 3R rated enclosure as standard. Sound Levels All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Table 9-2. Average Sound Levels NEMA ST-20 Average Sound Level in dB kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 CA08101001E Transformers General Purpose Transformers 9-3 November 2003 Vol. 1, Ref. No. [0303] Single-Phase, Types EP, DS-3, 60 Hz Winding Terminations Series-Multiple Windings Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Ventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. Eaton’s Cutler-Hammer business recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications Please refer to Page 9-122. 9 The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Transformers General Purpose Transformers 9-4 November 2003 Single-Phase, Types EP, DS-3, 60 Hz Vol. 1, Ref. No. [0304] Product Selection Additional Product Selection information begins on Page 9-136. Type EP 3-37.5 kVA Type DS-3 15-167 kVA Table 9-3. Single-Phase Selection Information — Types EP, DS-3, 60 Hz 9 kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Frame Wiring Weathershield Style Lbs. H kg Diagram Catalog Price Number W D Number Number U.S. $ Price U.S. $ 120 x 240 Volts to 120/240 Volts .5 — 1 — 1.5 — — — — EP EP EP 115 115 115 6-1/2 8-3/8 10-3/4 2 3 5 — — — — — — EP EP EP 115 115 115 10-3/4 6-3/16 14-1/8 7-3/4 10-3/8 16 7.5 10 15 25 — — — — — — — — EP EP EP EP 115 115 115 115 16 19 19 22-3/8 37.5 50 DS-3 150 DS-3 150 37-5/8 22-5/8 37-5/8 22-5/8 4-7/8 6 6-3/16 10-3/8 13-3/8 13-3/8 16-3/8 4-5/8 5-3/4 6-1/8 13 31 40 165 213 273 124 152 157 117 146 156 6 FR57 14 FR59A 18 FR67 3E 3E 3E IndoorOutdoor — S10N11S51N — S10N11S01N — S10N11S16N 400. 720. 890. 6-1/8 40 65 8 9-7/8 113 273 359 406 157 197 263 156 203 251 18 FR68 29 FR176 51 FR177 3E 3E 3E IndoorOutdoor — S10N11S02N — S10N11S03N — S10N11S05N 965. 1,050. 1,425. 123 191 216 375 406 482 482 568 263 339 339 416 251 266 266 368 55 87 98 170 FR178 FR179 FR180 FR182 3E 3E 3E 3E IndoorOutdoor — — — — 1,830. 2,225. 2,780. 4,370. 19-1/2 306 19-1/2 340 956 956 574 574 495 495 139 FR817 154 FR818 3XD 3XD WS11 WS11 13 31 40 165 213 273 124 152 157 117 146 156 6 FR57 14 FR59A 18 FR67 26A 26A 26A IndoorOutdoor — S29N11S51N — S29N11S01N — S29N11S16N 410. 625. 770. 6-1/8 40 8 65 9-7/8 113 273 359 406 157 197 263 156 203 251 18 FR68 29 FR176 51 FR177 26A 26A 26A IndoorOutdoor — S29N11S02N — S29N11S03N — S29N11S05N 985. 1,200. 1,775. 26A 26A 26A 26A IndoorOutdoor — — — — 2,350. 2,830. 3,350. 4,780. 9-7/8 10-1/2 10-1/2 14-1/2 S10N11S07N S10N11S10N S10N11S15N S10N11S25N 350. T10P11S37 350. T10P11S50 5,490. 6,670. 208 Volts to 120/240 Volts .5 — 1 — 1.5 — — — — EP EP EP 115 115 115 6-1/2 8-3/8 10-3/4 4-7/8 6 6-3/16 2 3 5 — — — — — — EP EP EP 115 115 115 10-3/4 14-1/8 16 6-3/16 7-3/4 10-3/8 7.5 10 15 25 — — — — — — — — EP EP EP EP 115 115 115 115 16 19 19 22-3/8 10-3/8 13-3/8 13-3/8 16-3/8 9-7/8 10-1/2 10-1/2 14-1/8 123 193 216 375 406 482 482 568 263 339 339 416 251 266 266 359 55 87 98 170 25 2@+2.5% 4@-2.5% DS-3 150 37.5 2@+2.5% 4@-2.5% DS-3 150 50 2@+2.5% 4@-2.5% DS-3 150 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 212 19-1/2 306 19-1/2 340 793 956 956 574 574 574 445 495 495 96 FR816 260A 139 FR817 260A 154 FR818 260A WS11 WS11 WS11 350. T29M11S25 350. T29M11S37 350. T29M11S50 3,740. 4,580. 5,560. 42-1/8 42-1/8 24 24 23-3/8 510 1070 23-3/8 600 1070 610 610 594 594 232 FR819 260A 272 FR820 260A WS16 WS16 800. T29M11S75 800. T29R11S99 7,860. 9,760. 75 100 2@+2.5% 4@-2.5% DS-3 150 1@+5% 2@-5% DS-3 150 4-5/8 5-3/4 6-1/8 FR178 FR179 FR180 FR182 S29N11S07N S29N11S10N S29N11S15N S29N11S25N 277 Volts to 120/240 Volts .5 — 1 — 1.5 — — — EP EP EP 115 115 115 6-1/2 8-3/8 10-3/4 4-7/8 6 6-3/16 2 3 5 — — — — — — EP EP EP 115 115 115 10-3/4 14-1/8 16 6-3/16 7-3/4 10-3/8 7.5 10 15 25 — — — — — — — — EP EP EP EP 115 115 115 115 16 19 19 22-3/8 10-3/8 13-3/8 13-3/8 16-3/8 9-7/8 10-1/2 10-1/2 14-1/8 25 2@+2.5% 4@-2.5% DS-3 150 37.5 2@+2.5% 4@-2.5% DS-3 150 50 2@+2.5% 4@-2.5% DS-3 150 31-1/4 37-5/8 37-5/8 42-1/8 42-1/8 75 100 2@+2.5% 4@-2.5% DS-3 150 2@+2.5% 4@-2.5% DS-3 150 4-5/8 5-3/4 6-1/8 13 31 40 165 213 273 124 152 157 117 146 156 6 FR57 514B 14 FR59A 514B 18 FR67 514B IndoorOutdoor — S27N11S51A — S27N11S01A — S27N11S16A 410. 625. 770. 6-1/8 40 8 65 9-7/8 113 273 359 405 157 197 263 156 203 251 18 FR68 514B 29 FR176 514B 51 FR177 514B IndoorOutdoor — S27N11S02A — S27N11S03N — S27N11S05N 985. 1,200. 1,775. 123 193 216 375 406 482 482 568 263 339 339 416 251 266 266 359 55 87 98 170 IndoorOutdoor — — — — 2,350. 2,830. 3,350. 4,780. 22-5/8 22-5/8 22-5/8 17-1/2 212 19-1/2 306 19-1/2 340 793 956 956 574 574 574 445 495 495 96 FR816 262C 139 FR817 262C 154 FR818 262C WS11 WS11 WS11 350. T27M11S25 350. T27M11S37 350. T27M11S50 3,740. 4,580. 5,560. 24 24 23-3/8 510 1070 23-3/8 600 1070 610 610 594 594 232 FR819 262C 272 FR820 262C WS16 WS16 800. T27M11S75 800. T27M11S99 7,860. 9,760. FR178 FR179 FR180 FR182 514B 514B 514B 514B S27N11S07N S27N11S10N S27N11S15N S27N11S25N Contact Eaton’s Cutler-Hammer business for availability of 0.05 – 0.25 kVA designs. 1@+5%, 2@-5% at 240 volts primary; 2@+2.5%, 4@-2.5% at 480 volts primary. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers General Purpose Transformers 9-5 November 2003 Single-Phase, Types EP, DS-3, 60 Hz Vol. 1, Ref. No. [0305] Table 9-4. Single-Phase Selection Information — Types EP, DS-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Lbs. Dimensions (mm) Wt. Frame kg W D H Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 240 x 480 Volts to 120/240 Volts .050 — .075 — .100 — — — — EP EP EP 115 115 115 6-1/2 6-1/2 6-1/2 3-7/8 3-7/8 3-7/8 3-1/2 3-1/2 3-1/2 7 7 7 165 165 165 98 98 98 89 89 89 3 FR52 3 FR53 3 FR54 3A 3A 3A IndoorOutdoor — S20N11S81N — S20N11S85N — S20N11S82N 75. 85. 95. .150 — .25 — .5 — — — — EP EP EP 115 115 115 6-1/2 6-1/2 6-1/2 3-7/8 4-7/8 4-7/8 3-1/2 3-7/8 4-5/8 8 12 13 165 165 165 98 124 124 89 98 117 4 FR55 5 FR56 6 FR57 3A 3A 3A IndoorOutdoor — S20N11S83N — S20N11S26N — S20N11S51N 110. 135. 170. .75 1 1.5 — — — — — — EP EP EP 115 115 115 8-3/8 8-3/8 10-3/4 6 6 6-3/16 5-3/4 5-3/4 6-1/8 21 31 40 213 213 273 152 152 157 146 146 156 10 FR58A 14 FR59A 18 FR67 3A 3A 3A IndoorOutdoor — S20N11S76N — S20N11S01N — S20N11S16N 220. 260. 320. 2 3 3 — — — — EP EP EP 115 115 115 10-3/4 14-1/8 14-1/8 6-3/16 7-3/4 7-3/4 6-1/8 8 8 40 65 65 273 359 359 157 197 197 156 203 203 18 FR68 29 FR176 29 FR176 3A 3A 9A IndoorOutdoor — S20N11S02N — S20N11S03N — S20K11S03N 410. 500. 525. 5 5 7.5 — — EP EP EP 115 115 115 16 16 16 10-3/8 10-3/8 10-3/8 9-7/8 9-7/8 9-7/8 113 113 123 406 406 406 263 263 263 251 251 251 51 FR177 51 FR177 55 FR178 3A 9A 3A IndoorOutdoor — S20N11S05N — S20K11S05N — S20N11S07N 740. 775. 980. 7.5 10 10 EP EP EP 115 115 115 16 19 19 10-3/8 13-3/8 13-3/8 9-7/8 10-1/2 10-1/2 123 193 193 406 482 482 263 339 339 251 266 266 55 FR178 87 FR179 87 FR179 9A 3A 9A IndoorOutdoor — S20K11S07N — S20N11S10N — S20K11S10N 1,030. 1,180. 1,240. 15 15 25 — 115 115 115 19 13-3/8 19 13-3/8 22-3/8 16-3/8 10-1/2 10-1/2 14-1/2 216 216 375 482 482 568 339 339 416 266 266 368 98 FR180 98 FR180 170 FR182 3A 23A 3A IndoorOutdoor — S20N11S15N — S20L11S15N — S20N11S25N 1,540. 1,600. 1,900. 25 37.5 — S20L11S25N — S20L11S37 2,250. 9,400. 15 25 37.5 50 75 100 167 — — — — — — — EP EP EP EP EP 115 115 22-3/8 16-3/8 28-1/4 22-5/8 14-1/2 14-5/8 375 950 568 717 416 575 368 371 170 FR182 23A 432 FR300A 23A IndoorOutdoor DS-3 150 DS-3 150 DS-3 150 30-1/4 16-7/8 31-1/4 22-5/8 37-5/8 22-5/8 15-7/8 17-1/2 19-1/2 147 212 306 768 793 956 428 574 574 402 445 495 67 FR815 96 FR816 139 FR817 3XA 3XA 3XA WS15 WS11 WS11 350. T20P11S15 350. T20P11S25 350. T20P11S37 1,440. 1,870. 2,290. 150 150 150 150 37-5/8 42-1/8 42-1/8 62-1/2 19-1/2 340 956 23-3/8 510 1070 23-3/8 600 1070 34 1200 1597 574 610 610 762 495 594 594 863 154 232 272 545 3XA 3XA 3XA 288A WS11 WS16 WS16 WS13 350. 800. 800. 800. 3,220. 3,930. 4,880. 9,500. DS-3 DS-3 DS-3 2@+2.5% 4@-2.5% DS-3 22-5/8 24 24 30 FR818 FR819 FR820 FR814 T20P11S50 T20P11S75 T20P11S99 T48M11S67D 1@+10% FCBN at 240 volts; 2@+5% FCBN at 480 volts. 2@+5% FCBN at 240 volts; 4@+2.5% FCBN at 480 volts. 1@+5%, 2@-5% at 240 volts primary; 2@+2.5%, 4@-2.5% at 480 volts primary. 480V primary to 120/240 volts secondary. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers General Purpose Transformers 9-6 November 2003 Single-Phase, Types EP, DS-3, 60 Hz Vol. 1, Ref. No. [0306] Table 9-5. Single-Phase Selection Information — Types EP, DS-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 190/200/208/220 x 380/400/416/440 Volts to 110/220 Volts 50/60 Hz — Export Model IP 22 Rated .5 1 1.5 2 — — — — — — — — EP EP EP EP 115 115 115 115 10-3/4 10-3/4 10-3/4 11-1/8 6-1/8 6-1/8 6-1/8 7-3/4 6-5/8 6-5/8 6-5/8 8 42 42 46 70 273 273 273 281 155 155 155 197 166 166 166 203 19 19 21 33 FR67 FR67 FR67 FR176 538A 538A 538A 538A IndoorOutdoor — — — — S40N14S51CE S40N14S01CE S40N14S16CE S40N14S02CE 760. 830. 1,030. 1,225. 3 5 7.5 — — — — — — EP EP EP 115 115 115 12-7/8 12-7/8 15-7/8 10-3/8 10-3/8 13-3/8 9-7/8 9-7/8 10-5/8 113 140 193 326 326 402 264 264 340 251 251 267 51 63 87 FR177 FR178 FR179 538A 538A 538A IndoorOutdoor — S40N14S03CE — S40N14S05CE — S40N14S07CE 1,570. 2,000. 2,625. — — — — EP EP 115 115 15-7/8 17-1/8 13-3/8 16-3/8 10-5/8 14-1/8 216 375 402 433 340 415 267 359 98 170 FR180 FR182 538A 538A IndoorOutdoor — S40N14S10CE — S40N14S15CE 3,160. 4,060. 8 9-7/8 9-7/8 65 113 123 359 406 406 195 263 263 203 251 251 29 51 55 FR176 FR177 FR178 3A 3A 3A IndoorOutdoor — S20N11S03SS — S20N11S05SS — S20N11S07SS 750. 1,110. 1,470. 10-1/2 10-1/2 14-1/8 179 216 375 482 482 566 339 339 416 266 266 359 87 98 170 FR179 FR180 FR182 3A 3A 3A IndoorOutdoor — S20N11S10SS — S20N11S15SS — S20N11S25SS 1,770. 2,200. 2,850. 5-3/4 6-1/8 6-1/8 31 40 40 213 273 273 152 157 157 146 156 156 14 18 18 FR59A FR67 FR68 2D 2D 2D IndoorOutdoor — S48G11S01N — S48G11S16N — S48G11S02N 312. 385. 495. 10 15 240 x 480 Volts to 120/240 Volts Stainless Steel 3 5 7.5 10 15 25 9 — — — — — — EP EP EP 115 115 115 14-1/8 16 16 — — — — — — EP EP EP 115 115 115 19 13-3/8 19 13-3/8 21-5/16 16-3/8 7-11/16 10-3/8 10-3/8 480 Volts to 120/240 Volts 1 1.5 2 — — — EP EP EP 115 115 115 8-3/8 10-3/4 10-3/4 3 3 5 — 2@-5% EP 2@+2.5% 2@+2.5% EP — 2@-5% EP 115 115 115 14-1/8 14-1/8 16 7-3/4 7-3/4 10-3/8 8 8 9-7/8 65 65 113 359 359 406 197 197 263 203 203 251 29 29 51 FR176 FR176 FR177 2D 16A 2D IndoorOutdoor — S48G11S03N — S48D11S03N — S48G11S05N 600. 600. 890. 5 7.5 7.5 2@+2.5% 2@+2.5% EP — 2@-5% EP 2@+2.5% 2@+2.5% EP 115 115 115 16 16 16 10-3/8 10-3/8 10-3/8 9-7/8 9-7/8 9-7/8 113 123 123 406 406 406 263 263 263 251 251 251 51 55 55 FR177 FR178 FR178 16A 2D 16A IndoorOutdoor — S48D11S05N — S48G11S07N — S48D11S07N 890. 1,180. 1,180. 10 10 15 — 2@-5% EP 2@+2.5% 2@+2.5% EP — 2@-5% EP 115 115 115 19 19 19 13-3/8 13-3/8 13-3/8 10-1/2 10-1/2 10-1/2 193 193 216 482 482 482 339 339 339 266 266 266 87 87 98 FR179 FR179 FR180 2D 16A 2D IndoorOutdoor — S48G11S10N — S48D11S10N — S48G11S15N 1,415. 1,415. 1,850. 15 25 25 2@+2.5% 2@+2.5% EP — 2@-5% EP 2@+2.5% 4@-2.5% EP 115 115 115 19 22-3/8 20-3/4 13-3/8 16-3/8 19-1/8 10-1/2 14-1/8 13-5/8 216 375 175 482 568 525 339 416 483 266 359 349 98 170 80 FR180 FR182 FR132 16A 2D 83A IndoorOutdoor — S48D11S15N — S48G11S25N — S48M11S25N 1,850. 2,395. 2,395. 2,620. 3,500. 4,430. 2@-5% 2@-5% 2@-5% 6 6-3/16 6-3/16 480 Volts to 120/240 Volts Stainless Steel, Copper Windings 10 15 25 2@+2.5% 2@+2.5% EP 2@+2.5% 2@+2.5% EP 2@+2.5% 4@-2.5% EP 115 115 115 19 19 20-3/4 13-3/8 13-3/8 19-1/8 10-1/2 10-1/2 13-5/8 208 235 175 482 482 525 339 339 483 266 266 349 94 106 80 FR179 FR180 FR132 16A 16A 83A IndoorOutdoor — S48D11S10SSCU — S48D11S15SSCU — S48M11S25SSCU 600 Volts to 120/240 Volts .5 .75 1 — — — 2@-5% 2@-5% 2@-5% EP EP EP 115 115 115 6-1/2 8-3/8 8-3/8 4-7/8 6 6 4-5/8 5-3/4 5-3/4 13 21 31 165 213 213 124 152 152 117 146 146 6 10 14 FR57 FR58A FR59A 2I 2I 2I IndoorOutdoor — S60G11S51N — S60G11S76N — S60G11S01N 255. 330. 390. 1.5 2 3 — — — 2@-5% 2@-5% 2@-5% EP EP EP 115 115 115 10-3/4 10-3/4 14-1/8 6-3/16 6-3/16 7-3/4 6-1/8 6-1/8 8 40 40 65 273 273 359 157 157 197 156 156 203 18 18 29 FR67 FR68 FR176 2I 2I 2I IndoorOutdoor — S60G11S16N — S60G11S02N — S60G11S03N 475. 610. 740. 5 7.5 10 — — — 2@-5% 2@-5% 2@-5% EP EP EP 115 115 115 16 16 19 10-3/8 10-3/8 13-3/8 9-7/8 9-7/8 10-1/2 113 123 193 406 406 482 263 263 339 251 251 266 51 55 87 FR177 FR178 FR179 2I 2I 2I IndoorOutdoor — S60G11S05N — S60G11S07N — S60G11S10N 1,110. 1,460. 1,760. 15 25 25 — — 2 @ 2.5% 4@-2.5% 4@-2.5% 4@-2.5% EP EP EP 115 115 115 19 22-3/8 20-3/4 13-3/8 16-3/8 19-1/8 10-1/2 14-1/8 13-5/8 216 375 175 482 568 525 339 416 483 266 359 349 98 170 80 FR180 FR182 FR132 527A 527A 83B IndoorOutdoor — S60J11S15N — S60J11S25N — S60M11S25N 2,400. 2,825. 2,825. 25 37.5 50 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DS-3 DS-3 DS-3 150 150 150 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 212 306 340 793 956 956 574 574 574 445 495 495 96 139 154 FR816 FR817 FR818 276B 276B 276B WS11 WS11 WS11 350. T60M11S25B 350. T60M11S37 350. T60M11S50D 2,240. 2,750. 3,340. 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DS-3 DS-3 DS-3 150 150 150 42-1/8 42-1/8 62-7/8 24 24 30 23-3/8 23-3/8 34 510 600 1200 1070 1070 1597 610 610 762 594 594 863 232 272 545 FR819 FR820 FR814 276B 276B 288B WS16 WS16 WS13 800. T60M11S75 800. T60M11S99 800. T60M11S67A 4,720. 5,860. 11,400. 75 100 167 NEMA 3R, 316 stainless steel enclosure. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers General Purpose Transformers 9-7 November 2003 Single-Phase, Types EP, DS-3, 60 Hz Vol. 1, Ref. No. [0307] Table 9-6. Single-Phase Selection Information — Types EP, DS-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Frame Wiring Weathershield Style Lbs. H kg Diagram Catalog Price Number W D Number Number U.S. $ Price U.S. $ 2400 Volts to 120/240 Volts 1.5 3 5 10 15 25 37.5 50 75 100 6-1/8 40 273 157 156 181 FR68 18A Recommended Indoor Only — S42N11S16N 3,100. 10-3/8 10-3/8 13-3/8 16-3/8 16-3/8 9-7/8 9-7/8 10-1/2 14-1/8 14-1/8 113 123 216 375 405 406 406 482 566 668 263 263 339 416 416 251 251 266 359 359 51 55 87 170 183 FR177 FR178 FR179 FR182 FR190 12A 12A 12A 12A 12A Recommended Indoor Only — — — — — S42J11S03N S42J11S05N S42J11S10N S42J11S15N S42J11S25N 3,290. 3,460. 4,930. 5,830. 8,270. 28 30 30 36 22 24 24 27 20 26 26 26 300 420 500 570 684 732 732 879 537 586 586 659 488 635 635 635 137 191 228 260 Recommended Indoor Only — — — — T42D11S37 T42D11S50 T42D11S75 T42D11S99 5,500. 6,350. 7,860. 8,600. 150 150 28 30 22 24 20 26 300 420 684 732 537 586 488 635 137 191 Recommended Indoor Only — T42D21S37 — T42D21S50 5,500. 6,350. 6-1/8 40 273 157 156 181 FR68 524G Recommended Indoor Only — S46N11S16N 2,580. 12B 12B 12B 12B Recommended Indoor Only — — — — S46J11S03N S46J11S05N S46J11S10A S46J11S15A 3,295. 3,460. 4,930. 5,830. — — EP 115 10-3/4 — — — — — 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% EP EP EP EP EP 115 115 115 115 115 16 16 19 22-3/8 26-3/8 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 2@-2.5% 2@-2.5% 2@-2.5% 2@-2.5% DS-3 DS-3 DS-3 DS-3 150 150 150 150 DS-3 DS-3 6-3/16 2400 Volts to 240/480 Volts 37.5 50 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 4160 Volts to 120/240 Volts 1.5 — — EP 115 10-3/4 3 5 10 15 — — — — 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% EP EP EP EP 115 115 115 115 16 16 19 22-5/16 10-3/8 10-3/8 13-3/8 16-3/8 9-7/8 9-7/8 10-1/2 14-1/8 113 123 193 375 406 406 482 566 263 263 339 416 251 251 266 359 51 55 87 170 FR177 FR178 FR179 FR182 25 37.5 50 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DS-3 DS-3 DS-3 150 150 150 28 28 30 22 22 24 20 20 26 280 300 420 984 684 732 537 537 586 488 488 635 128 137 191 Recommended Indoor Only — T46D11S25 — T46D11S37 — T46D11S50 4,800. 5,500. 6,350. 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DS-3 DS-3 DS-3 150 150 150 30 36 50 24 27 33 26 26 35 500 570 1000 732 879 1220 586 659 806 635 635 854 228 260 455 Recommended Indoor Only — T46D11S75 — T46D11S99 — T46D11S67 7,860. 8,600. 16,800. DS-3 DS-3 DS-3 DS-3 150 150 150 150 28 30 30 36 22 24 24 27 20 26 26 26 300 420 500 570 684 732 732 879 537 586 586 659 488 635 635 635 137 191 228 260 Recommended Indoor Only — — — — T46D21S37 T46D21S50 T46D21S75 T46D21S99 5,500. 6,350. 7,860. 8,600. 75 100 167 6-3/16 4160 Volts to 240/480 Volts 37.5 50 75 100 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 2@-2.5% 2@-2.5% 2@-2.5% 2@-2.5% No UL label. Refer to your Cutler-Hammer sales office. NEMA 3R enclosure and/or UL label available at additional cost. Specify at time of order entry if required. Not seismic qualified. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers General Purpose Transformers 9-8 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0308] Application Description Options and Accessories The basic purpose of a transformer is voltage transformation as near as practically possible to the load for economy and distribution of power. Typical loads for dry-type distribution transformers include lighting, heating, air conditioners, fans and machine tools. Such loads are found in commercial, institutional, industrial and residential structures. Please refer to Page 9-120. Features, Benefits and Functions Type EPT Encapsulated 9 Product Description Type EPT ■ ■ ■ ■ ■ ■ ■ Sand and Resin Encapsulated design. Suitable for indoor or outdoor applications. Totally enclosed, non-ventilated enclosures. Enclosures are NEMA 3R rated. Mountable in any position indoors and upright only outdoors. 185ºC Insulation System, 115ºC rise standard. Available in ratings through 75 kVA and 4160 volts primary. Type DT-3 ■ ■ ■ ■ ■ Ventilated, NEMA 2 enclosure standard. Suitable for indoor applications, outdoors when weathershields are also installed. Upright mounting only. 220ºC Insulation System, 150ºC rise standard. Available in three-phase ratings 15 – 1500 kVA and up to 4160 volts primary. ■ UL listed. ■ 60 Hz operation standard, 50/60 Hz operation available. ■ Short-term overload capability as required by ANSI. ■ Meet NEMA ST-20 sound levels. Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hertz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one half hour; 150% load for one hour; and 125% load for four hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Seismically Qualified Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose Transformers 9-9 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0309] Insulation System and Temperature Rise Sound Levels Series-Multiple Windings Industry standards classify insulation systems and rise as shown below: All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Table 9-7. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Eaton’s Cutler-Hammer ventilated transformers, Type DT-3, utilize a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Cutler-Hammer encapsulated transformers, Type EPT, utilize a NEMA 3R rated enclosure as standard. Table 9-8. Average Sound Levels NEMA ST-20 Average Sound level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Technical Data and Specifications Please refer to Page 9-122. Applies to general purpose ventilated transformers only. Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Ventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers General Purpose Transformers 9-10 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0310] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-9. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 208 ∆ Volts to 480Y/277 Volts 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 140 FR909 FR910A FR912A 280E 280E 280E WS31 WS31 WS31 350. V29M47T15N 350. V29M47T30N 350. V29M47T45N 2,030. 2,590. 3,150. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 660 486 486 585 217 272 344 FR914B FR915B FR916A 280E 280E 280E WS33 WS33 WS19 350. V29M47T75N 350. V29M47T12N 350. V29M47T49N 4,460. 6,450. 8,100. 225 300 500 1@+5% 1@+5% — DT-3 DT-3 DT-3 150 150 150 62-1/4 62-1/4 75 31-1/4 31-1/4 44-1/2 30-1/4 30-1/4 36 1600 1600 2400 1581 1581 1905 794 794 1130 768 768 914 728 FR918A 728 FR918A 1088 FR919 333B 333B 290B WS34 WS34 WS35 800. V29R47T22N 800. V29R47T33N 1,360. V29G47T55N 11,850. 15,000. 22,400. EPT EPT EPT 115 115 115 13-3/8 15-7/8 15-7/8 15-15/16 16-1/2 16-1/2 8-5/16 9-7/8 9-7/8 116 143 166 340 403 403 405 419 419 211 251 251 53 65 75 FR201 FR200 FR103 IndoorOutdoor — Y25G19T03A — Y25G19T06A — Y25G19T09A 1,380. 1,680. 2,170. — Y25G19T15A — Y25M19T30A — Y25M19T45A 2,730. 5,200. 6,500. 2@-5% 2@-5% 2@-5% 220 ∆ Volts to 190Y/110 Volts 3 6 9 9 — — — 2@-5% 2@-5% 2@-5% 70I 70I 70I 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 17-3/8 26-5/8 26-1/2 19-11/16 10-7/16 25-1/4 12-3/4 28-1/2 14-5/8 275 422 660 442 676 673 500 638 724 265 324 372 125 191 299 FR95 FR243 FR244 IndoorOutdoor 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 FR910A FR912A 280Q 280Q 280Q WS31 WS31 WS31 350. V25M19T15A 350. V25M19T30A 350. V25M19T45A 1,825. 2,330. 2,840. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B FR915B FR916A 280Q 280Q 280Q WS33 WS33 WS19 350. V25M19T75A 350. V25M19T12A 350. V25M19T49A 4,010. 5,800. 7,290. 225 300 500 1@+5% 1@+5% — DT-3 DT-3 DT-3 150 150 150 62-1/4 62-1/4 75 31-1/4 31-1/4 44-1/2 30-1/4 30-1/4 36 1600 1600 2400 1581 1581 1905 794 794 1130 768 768 914 728 FR918A 728 FR918A 1088 FR919 289F 289F 289F WS34 WS34 WS35 800. V25R19T22A 800. V25R19T33A 1,360. V25G19T55A 10,660. 13,500. 21,600. EPT EPT EPT 115 115 115 13-3/8 15-7/8 15-7/8 15-15/16 16-1/2 16-1/2 8-5/16 9-7/8 9-7/8 116 143 166 340 403 403 405 419 419 211 251 251 53 65 75 FR201 FR200 FR103 70Q 70Q 70Q IndoorOutdoor — Y25G28T03A — Y25G28T06A — Y25G28T09A 1,590. 1,935. 1,700. — Y25G28T15A — Y25M28T30A — Y25M28T45A 2,510. 6,000. 7,500. 2@-5% 2@-5% 2@-5% 220 ∆ Volts to 208Y/120 Volts 3 6 9 — — — 2@-5% 2@-5% 2@-5% 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 17-3/8 26-3/8 26-1/2 19-11/16 10-7/16 25-1/4 12-3/4 28-1/2 14-5/8 275 422 660 442 676 673 500 638 724 265 324 372 125 191 299 FR95 FR243 FR244 70Q 84AF 84AF IndoorOutdoor 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 FR910A FR912A 280Q 280Q 280Q WS31 WS31 WS31 350. V25M28T15A 350. V25M28T30A 350. V25M28T45A 1,825. 2,330. 2,840. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B FR915B FR916A 280Q 280Q 280Q WS33 WS33 WS19 350. V25M28T75A 350. V25M28T12A 350. V25M28T49A 4,010. 5,800. 7,290. 225 300 500 1@+5% 1@+5% — DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 289F 289F 289F WS34 WS34 WS35 800. V25R28T22A 800. V25R28T33A 1,360. V25G28T55A 10,660. 13,500. 21,600. EPT EPT EPT 115 115 115 13-3/8 15-7/8 15-7/8 15-15/16 16-1/2 16-1/2 8-5/16 9-7/8 9-7/8 116 143 166 340 403 403 405 419 419 211 251 251 53 65 75 FR201 FR200 FR103 70X 70X 70X IndoorOutdoor — Y25G37T03A — Y25G37T06A — Y25G37T09A 1,590. 1,935. 2,505. — Y25G37T15A — Y25M37T30A — Y25M37T45A 3,150. 6,000. 7,500. 2@-5% 2@-5% 2@-5% 220 ∆ Volts to 380Y/220 Volts 3 6 9 — — — 2@-5% 2@-5% 2@-5% 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 17-3/8 26-5/8 26-1/2 19-11/16 10-7/16 25-1/4 12-3/4 28-1/2 14-5/8 275 422 660 442 676 673 500 638 724 265 324 372 125 191 299 FR95 FR243 FR244 70X 84AF 84AF IndoorOutdoor 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 FR910A FR912A 280Q 280Q 280Q WS31 WS31 WS31 350. V25M37T15A 350. V25M37T30A 350. V25M37T45A 1,890. 2,415. 2,940. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B FR915B FR916A 280Q 280Q 280Q WS33 WS33 WS19 350. V25M37T75A 350. V25M37T12A 350. V25M37T49A 4,155. 6,020. 7,560. 225 300 500 1@+5% 1@+5% — DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 289F 289F 289F WS34 WS34 WS35 800. V25R37T22A 800. V25R37T33A 1,360. V25G37T55A 11,060. 14,000. 21,600. 2@-5% 2@-5% 2@-5% Refer to your Cutler-Hammer sales office. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers General Purpose Transformers 9-11 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0311] Table 9-10. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Dimensions (Inches) Type °C Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Diagram Weathershield Style Wiring Catalog Price Number Number Number U.S. $ Price U.S. $ 240 ∆ Volts to 208Y/120 Volts 9 15 30 45 — — 2@+2.5% 2@+2.5% 2@-5% 2@-5% 4@-2.5% 4@-2.5% EPT EPT EPT EPT 115 115 115 115 15-7/8 17-3/8 26-5/8 26-1/2 16-1/2 19-3/4 25-1/4 28-1/2 9-7/8 10-1/2 12-3/4 14-5/8 166 275 422 660 403 441 676 673 419 499 638 723 251 265 323 371 75 124 191 299 FR103 FR95 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 140 FR909 280C FR910A 280C FR912A 280C 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 712 486 486 585 217 272 344 225 300 500 1@+5% 1@+5% — DT-3 DT-3 DT-3 150 150 150 62-1/4 64-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 793 794 1130 616 768 914 EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 70F 70F 70F 70F IndoorOutdoor — — — — Y38G19T03A Y38G19T06A Y38G19T09A Y38G19T15A 1,220. 1,480. 1,920. 2,415. 84AC 84AC 84AC IndoorOutdoor — Y38M19T30A — Y38M19T45A — Y38M19T75A 4,600. 5,750. 7,150. 2@-5% 2@-5% 2@-5% Y24G28T09N Y24G28T15N Y24M28T30N Y24M28T45N 2,510. 3,150. 6,000. 7,500. WS31 WS31 WS31 350. V24M28T15B 350. V24M28T30N 350. V24M28T45N 1,825. 2,330. 2,840. FR914B 280C FR915B 280C FR916A 280C WS33 WS33 WS19 350. V24M28T75N 350. V24M28T12N 350. V24M28T49N 4,010. 5,800. 7,290. 499 FR918A 289A 728 FR918A 289A 1088 FR919 290A WS34 WS34 WS35 800. V24R28T22N 800. V24R28T33N 1,360. V24G28T55N 10,660. 15,600. 22,600. 70C 70C 84C 84C IndoorOutdoor — — — — 380 ∆ Volts to 190Y/110 Volts 3 6 9 15 — — — — 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 781 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 280L FR910A 280L FR912A 280L WS31 WS31 WS31 350. V38M19T15A 350. V38M19T30A 350. V38M19T45A 1,800. 2,000. 2,500. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B 280L FR915B 280L FR916A 280L WS33 WS33 WS19 350. V38M19T75A 350. V38M19T12A 350. V38M19T49A 3,400. 4,900. 6,850. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 499 FR917 280L 728 FR918A 1088 FR919 WS34 WS34 WS35 800. V38M19T22A 800. V38M19T33A 1,360. V38M19T55A 9,100. 11,500. 18,500. EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 70D 70D 70D 70D IndoorOutdoor — — — — Y38G28T03A Y38G28T06A Y38G28T09A Y38G28T15A 1,275. 1,550. 2,005. 2,520. 84R 84R 84R IndoorOutdoor — Y38M28T30A — Y38M28T45A — Y38M28T75A 4,600. 5,750. 7,130. 2@-5% 2@-5% 2@-5% 2@-5% 380 ∆ Volts to 208Y/120 Volts 3 6 9 15 — — — — 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 781 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 280L FR910A 280L FR912A 280L WS31 WS31 WS31 350. V38M28T15A 350. V38M28T30A 350. V38M28T45A 1,800. 2,000. 2,500. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B 280L FR915B 280L FR916A 280L WS33 WS33 WS19 350. V38M28T75A 350. V38M28T12A 350. V38M28T49A 3,400. 4,900. 6,850. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 499 FR917 280L 728 FR918A 280L 1088 FR919 WS34 WS34 WS35 800. V38M28T22A 800. V38M28T33A 1,360. V38M28T55A 9,100. 11,500. 18,500. EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 70F 70F 70F 70F IndoorOutdoor — — — — Y38G31T03A Y38G31T06A Y38G31T09A Y38G31T15A 1,220. 1,480. 1,920. 2,415. 84R 84R 84R IndoorOutdoor — Y38M31T30A — Y38M31T45A — Y38M31T75A 4,600. 5,750. 7,130. 2@-5% 2@-5% 2@-5% 2@-5% 380 ∆ Volts to 220Y/127 Volts 3 6 9 15 — — — — 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 781 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 280L FR910A 280L FR912A 280L WS31 WS31 WS31 350. V38M31T15A 350. V38M31T30A 350. V38M31T45A 1,800. 2,000. 2,500. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B 280L FR915B 280L FR916A 280L WS33 WS33 WS19 350. V38M31T75A 350. V38M31T12A 350. V38M31T49A 3,400. 4,900. 6,850. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 499 FR917 280L 728 FR918A 280L 1088 FR919 275H WS34 WS34 WS35 800. V38M31T22A 800. V38M31T33A 1,360. V38M31T55A 9,100. 11,500. 18,500. 2@-5% 2@-5% 2@-5% 2@-5% Floor mount only. Refer to your Cutler-Hammer sales office. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers General Purpose Transformers 9-12 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0312] Table 9-11. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 380 ∆ Volts to 220 ∆ Volts 9 3 6 9 15 — — — — 2@-5% 2@-5% 2@-5% 2@-5% EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 75 2@+2.5% 112.5 2@+2.5% 150 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 225 300 500 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 2@+2.5% 2@+2.5% 2@+2.5% 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 281D FR910A 281D FR912A 281D WS31 WS31 WS31 350. V38M25T15A 350. V38M25T30A 350. V38M25T45A 1,800. 2,000. 2,500. 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B 281D FR915B 281D FR916A 281D WS33 WS33 WS19 350. V38M25T75A 350. V38M25T12A 350. V38M25T49A 3,400. 4,900. 6,850. 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 499 FR917 281D 728 FR918A 281D 1088 FR919 WS34 WS34 WS35 800. V38M25T22A 800. V38M25T33A 1,360. V38M25T55A 9,100. 11,500. 18,500. 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 70D 70D 70D 70D IndoorOutdoor — — — — Y38G37T03A Y38G37T06A Y38G37T09A Y38G37T15A 1,380. 1,670. 2,170. 2,730. 84H 84H 84H IndoorOutdoor — Y38M37T30A — Y38M37T45A — Y38M37T75A 5,200. 6,500. 8,060. 74K 74K 74K 74K IndoorOutdoor — — — — Y38G25T03A Y38G25T06A Y38G25T09A Y38G25T15A 1,220. 1,480. 1,920. 2,415. IndoorOutdoor — Y38M25T30A — Y38M25T45A — Y38M25T75A 4,600. 5,750. 7,150. 380 ∆ Volts to 380Y/220 Volts 3 6 9 15 — — — — 2@-5% 2@-5% 2@-5% 2@-5% EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 280L FR910A 280L FR912A 280L WS31 WS31 WS31 350. V38M37T15A 350. V38M37T30A 350. V38M37T45A 1,890. 2,415. 2,940. 75 2@+2.5% 112.5 2@+2.5% 150 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B 280L FR915B 280L FR916A 280L WS33 WS33 WS19 350. V38M37T75A 350. V38M37T12A 350. V38M37T49A 4,160. 6,020. 7,560. 225 300 500 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 499 FR917 280L 728 FR918A 280L 1088 FR919 WS34 WS34 WS35 800. V38M37T22A 800. V38M37T33A 1,360. V38M37T55A 11,060. 14,000. 22,400. 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 70F 70F 70F 70F IndoorOutdoor — — — — Y38G47T03A Y38G47T06A Y38G47T09A Y38G47T15A 1,590. 1,935. 2,505. 3,150. 84AB 84AB 84AB IndoorOutdoor — Y38M47T30A — Y38M47T45A — Y38M47T75A 6,000. 7,500. 9,300. 2@+2.5% 2@+2.5% 2@+2.5% 380 ∆ Volts to 480Y/277 Volts 3 6 9 15 — — — — 2@-5% 2@-5% 2@-5% 2@-5% EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 280L FR910A 280L FR912A 280L WS31 WS31 WS31 350. V38M47T15A 350. V38M47T30A 350. V38M47T45A 2,090. 2,675. 3,260. 75 2@+2.5% 112.5 2@+2.5% 150 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B 280L FR915B 280L FR916A 280L WS33 WS33 WS19 350. V38M47T75A 350. V38M47T12A 350. V38M47T49A 4,600. 6,665. 8,370. 225 300 500 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 499 FR917 280L 728 FR918A 280L 1088 FR919 WS34 WS34 WS35 800. V38M47T22A 800. V38M47T33A 1,360. V38M47T55A 12,245. 15,500. 24,800. 2@+2.5% 2@+2.5% 2@+2.5% Refer to your Cutler-Hammer sales office. Floor mount only. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers General Purpose Transformers 9-13 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0313] Table 9-12. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 416 ∆ Volts to 208Y/120 Volts 3 6 9 15 — — — — 30 45 75 2@-5% 2@-5% 2@-5% 2@-5% 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 70V 70V 70V 70V IndoorOutdoor — — — — Y43G28T03A Y43G28T06A Y43G28T09A Y43G28T15A 1,275. 1,550. 2,005. 2,520. 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 84I 84I 84I IndoorOutdoor — Y43M28T30A — Y43M28T45A — Y43M28T75A 4,600. 5,750. 7,150. 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 FR910A FR912A 280P 280P 280P WS31 WS31 WS31 350. V43M28T15A 350. V43M28T30A 350. V43M28T45A 1,800. 2,000. 2,530. 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B FR915B FR916A 280P 280P 280P WS33 WS33 WS19 350. V43M28T75A 350. V43M28T12A 350. V43M28T49A 3,450. 4,950. 6,850. 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 280P 280P WS34 WS34 WS35 800. V43M28T22A 800. V43M28T33A 1,360. V43M28T55A 9,080. 11,500. 18,500. EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 70G 70G 70G 70G IndoorOutdoor — — — — Y44G31T03A Y44G31T06A Y44G31T09A Y44G31T15A 1,590. 1,935. 2,505. 3,150. 84O 84O 84O IndoorOutdoor — Y44M31T30A — Y44M31T45A — Y44M31T75A 4,600. 5,750. 7,150. EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 499 FR917 728 FR918A 1088 FR919 440 ∆ Volts to 220Y/127 Volts 3 6 9 15 — — — — 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 FR910A FR912A 280J 280J 280J WS31 WS31 WS31 350. V44M31T15A 350. V44M31T30A 350. V44M31T45A 1,800. 2,000. 2,500. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B FR915B FR916A 280J 280J 280J WS33 WS33 WS19 350. V44M31T75A 350. V44M31T12A 350. V44M31T49A 3,420. 4,945. 6,220. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 280J 280J 275F WS34 WS34 WS35 800. V44M31T22A 800. V44M31T33A 1,360. V44M31T55A 9,100. 11,500. 18,500. 2@-5% 2@-5% 2@-5% 2@-5% 480 ∆ Volts to 208Y/120 Volts 3 6 6 — 2@-5% — 2@-5% 2@+2.5% 2@-2.5% EPT EPT EPT 115 115 115 13-3/8 15-7/8 15-7/8 16 16-1/2 16-1/2 8-3/8 9-7/8 9-7/8 116 143 143 339 403 403 404 419 419 211 251 251 52 64 64 FR201 FR200 FR200 70A 70A 72B IndoorOutdoor — Y48G28T03N — Y48G28T06N — Y48D28T06N 1,060. 1,290. 1,290. 9 9 9 — 2@-5% — 4@-2.5% 2@+2.5% 2@-2.5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 15-7/8 16-1/2 16-1/2 16-1/2 9-7/8 9-7/8 9-7/8 166 166 166 403 403 403 419 419 419 251 251 251 75 75 75 FR103 FR103 FR103 70A 503A 72B IndoorOutdoor — Y48G28T09N — Y48J28T09N — Y48D28T09N 1,670. 1,670. 1,670. 15 15 15 — 2@-5% — 4@-2.5% 2@+2.5% 2@-2.5% EPT EPT EPT 115 115 115 17-3/8 17-3/8 17-3/8 19-11/16 10-7/16 19-11/16 10-7/16 19-11/16 10-7/16 275 275 275 441 441 441 499 499 499 265 265 265 124 124 124 FR95 FR95 FR95 70A 72A 72B IndoorOutdoor — Y48G28T15N — Y48J28T15N — Y48D28T15N 2,100. 2,100. 2,100. 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 723 765 323 371 397 191 299 580 FR243 FR244 FR245 84A 84A 84A IndoorOutdoor — Y48M28T30N — Y48M28T45N — Y48M28T75N 4,000. 5,000. 6,800. 15 30 37.5 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 239 310 635 765 765 511 511 511 359 359 359 69 108 140 FR909 FR910A FR911A 280B 280B 280B WS31 WS31 WS31 350. V48M28T15B 350. V48M28T30K 350. V48M28T37K 1,350. 1,725. 2,040. 45 50 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 310 480 480 765 1000 1000 511 663 663 359 485 486 140 217 217 FR912A FR913B FR914B 280B 280B 280B WS31 WS33 WS33 350. V48M28T45K 350. V48M28T50J 350. V48M28T75J 2,100. 2,920. 2,970. 112.5 150 225 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 663 712 793 486 585 616 272 344 499 FR915B FR916A FR917 280B 280B 280B WS33 WS19 WS34 350. V48M28T12H 350. V48M28T49K 800. V48M28T22L 4,300. 5,400. 7,900. 2@+2.5% 2@+2.5% 2@+2.5% 1@+3.5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 62-1/4 75 75 68 31-1/4 44-1/2 44-1/2 64 30-1/4 36 36 45 1600 2400 2900 4350 1581 1905 1905 1727 794 1130 1130 1625 768 914 914 1143 728 FR918A 1088 FR919 1315 FR920 1972 280B 275A 275A WS34 WS35 WS35 300 500 750 1000 4@-2.5% 4@-2.5% 4@-2.5% 1@-3.5% 800. 1,360. 1,360. — V48M28T33K V48M28T55G V48M28T77F V48W28T11G 10,000. 16,000. 26,000. 46,500. Refer to your Cutler-Hammer sales office. Floor mount only. Not seismic qualified. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers General Purpose Transformers 9-14 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0314] Table 9-13. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 208Y/120 Volts — Copper Windings 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 2@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% EPT EPT EPT EPT 115 115 115 115 17-3/8 26-5/8 26-1/2 32-1/4 19-11/16 25-1/4 28-1/2 30-1/8 10-7/16 12-3/4 14-5/8 15-5/8 300 505 745 1450 441 676 673 819 499 638 723 765 265 323 371 397 136 230 339 659 FR95 FR243 FR244 FR245 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 25 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 14-1/8 19-1/8 172 300 370 550 635 765 765 1000 511 511 511 663 359 359 359 486 78 136 168 250 FR909 FR910A FR912A FR914B 280B 280B 280B 280B WS31 WS31 WS31 WS33 112.5 150 225 300 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 39-3/8 46-1/8 56 62-1/4 26-1/8 28 31-1/4 31-1/4 19-1/8 23 24-1/4 30-1/4 675 850 1200 2150 1000 1171 1422 1581 663 712 793 794 486 585 616 768 307 386 545 977 FR915B FR916A FR917 FR918A 280B 280B 280B 280B WS33 WS19 WS34 WS34 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 1@+3.5% 1@-3.5% DT-3 DT-3 DT-3 150 150 150 75 75 68 44-1/2 44-1/2 64 36 36 45 3100 1905 3600 1905 5500 1727 1130 1130 1625 914 914 1143 275A 275A WS35 WS35 500 750 1000 9 1409 FR919 1636 FR920 2500 72B 84A 84A 84A IndoorOutdoor — — — — Y48D28T15CU Y48M28T30CU Y48M28T45CU Y48M28T75CU 2,860. 5,440. 6,800. 9,100. 350. 350. 350. 350. V48M28T15CU V48M28T30CU V48M28T45CU V48M28T75CU 2,000. 2,380. 2,890. 4,390. 350. 350. 800. 800. V48M28T12CU V48M28T49CU V48M28T22CU V48M28T33CU 6,000. 8,200. 11,030. 14,000. 1,360. V48M28T55CU 1,360. V48M28T77CU — V48W28T11CU 22,350. 38,000. 65,100. 480 ∆ Volts to 208Y/120 Volts Stainless Steel 3 6 9 15 — 2@+2.5% 2@+2.5% 2@+2.5% 2@-5% 2@-2.5% 2@-2.5% 2@-2.5% EPT EPT EPT EPT 115 115 115 115 13-7/8 15-7/8 15-7/8 17-3/8 16 8-3/8 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 12-3/4 14-5/8 15-5/8 116 143 143 275 340 403 403 441 405 419 419 499 211 251 251 265 53 65 75 124 FR201 FR200 FR103 FR95 70A 72B 72B 72B IndoorOutdoor — — — — Y48G28T03SS Y48D28T06SS Y48D28T09SS Y48D28T15SS 1,590. 1,935. 2,500. 3,150. 422 660 1275 676 673 819 638 723 765 323 371 397 191 299 453 FR243 FR244 FR245 84A 84A 84A IndoorOutdoor — Y48M28T30SS — Y48M28T45SS — Y48M28T75SS 6,000. 7,500. 9,300. 480 ∆ Volts to 208Y/120 Volts Stainless Steel, Copper Windings 15 30 45 2@+2.5% 2@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 17-3/8 26-5/8 26-1/2 19-11/16 10-7/16 25-1/4 12-3/4 28-1/2 14-5/8 300 504 745 441 676 673 499 638 723 265 323 371 136 229 338 FR95 FR243 FR244 72B 84A 84A IndoorOutdoor — Y48D28T15SSCU — Y48M28T30SSCU — Y48M28T45SSCU 3,880. 7,400. 9,250. EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8 5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 70A 70A 70A 70A IndoorOutdoor — — — — Y48G31T03A Y48G31T06A Y48G31T09A Y48G31T15A 1,590. 1,935. 2,505. 3,150. 84K 84K 84K IndoorOutdoor — Y48M31T30A — Y48M31T45A — Y48M31T75A 4,600. 5,750. 7,150. 480 ∆ Volts to 220Y/127 Volts 3 6 9 15 — — — — 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20 1/8 20-1/8 20-1/8 14 1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 FR910A FR912A 280B 280B 280B WS31 WS31 WS31 350. V48M31T15A 350. V48M31T30A 350. V48M31T45A 1,550. 2,000. 2,415. 75 2@+2.5% 4@-2.5% 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B FR915B FR916A 280B 280B 280B WS33 WS33 WS19 350. V48M31T75A 350. V48M31T12A 350. V48M31T49A 3,415. 4,945. 6,210. 225 300 500 DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1422 1600 1581 2400 1905 794 794 1130 616 768 914 499 FR917 280B 728 FR918A 280B 1088 FR919 275A WS34 WS34 WS35 800. V48M31T22A 800. V48M31T33A 1,360. V48M31T55A 9,100. 11,500. 18,500. 2@-5% 2@-5% 2@-5% 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% Floor mount only. Refer to your Cutler-Hammer sales office. Not seismic qualified. NEMA 3R, 316 stainless steel enclosure. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers General Purpose Transformers 9-15 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0315] Table 9-14. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 240 ∆ Volts With 120 Volt Lighting Tap on B Phase 2@-5% 2@-5% 4@-2.5% EPT EPT EPT 115 115 115 13-3/8 15-7/8 15-7/8 16 16-1/2 16-1/2 8-3/8 9-7/8 9-7/8 116 143 166 339 403 403 404 419 419 211 251 251 52 64 75 FR201 FR200 FR103 74A 74A 73A IndoorOutdoor — Y48G24T03N — Y48G24T06N — Y48J24T09N 1,190. 1,450. 1,870. 15 30 45 — 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 17-3/8 26-5/8 26-1/2 19-3/4 25-1/4 28-1/2 10-1/2 12-3/4 14-5/8 275 422 660 441 676 673 499 638 723 265 323 371 124 191 299 FR95 FR243 FR244 73A 85A 85A IndoorOutdoor — Y48J24T15N — Y48M24T30N — Y48M24T45N 2,350. 4,480. 5,600. 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 25 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 14-1/8 19-1/8 152 230 310 480 635 765 765 1000 511 511 511 663 359 359 359 486 69 104 140 217 FR909 FR910A FR912A FR914B 282B 282B 282B 282B WS31 WS31 WS31 WS33 350. 350. 350. 350. V48M22T15B V48M22T30N V48M22T45N V48M22T75N 1,550. 2,000. 2,500. 3,420. 112.5 150 225 300 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 39-3/8 46-1/8 56 62-1/4 26-1/8 28-1/8 31-1/4 31-1/4 19-1/8 23 24-1/4 30-1/4 600 760 1100 1600 1000 1171 1422 1581 663 712 793 794 486 585 616 768 272 344 499 728 FR915B FR916A FR917 FR918A 282B 282B 282B 282B WS33 WS19 WS34 WS34 350. 350. 800. 800. V48M22T12N V48M22T49N V48M22T22N V48M22T33N 4,900. 6,210. 9,100. 11,500. 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 1@+3.5% 1@-3.5% DT-3 DT-3 DT-3 150 150 150 75 75 68 44-1/2 44-1/2 64 36 36 45 2400 1905 2900 1905 4350 1727 1130 1130 1625 914 914 1143 291A 291A WS35 WS35 EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 3 6 9 500 750 1000 — — — 1088 FR919 1315 FR920 1972 1,360. V48M22T55N 1,360. V48M22T77N — V48W22T11N 18,500. 32,600. 53,500. 480 ∆ Volts to 380Y/220 Volts 3 6 9 15 — — — — 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 75 2@+2.5% 4@-2.5% 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 225 300 500 DT-3 DT-3 DT-3 150 150 150 2@-5% 2@-5% 2@-5% 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 70R 70R 70R 70R IndoorOutdoor — — — — Y48G37T03A Y48G37T06A Y48G37T09A Y48G37T15A 1,590. 1,935. 2,505. 3,150. 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 84A 84A 84A IndoorOutdoor — Y48M37T30A — Y48M37T45A — Y48M37T75A 4,600. 5,750. 7,150. 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 FR910A FR912A 280B 280B 280B WS31 WS31 WS31 350. V48M37T15A 350. V48M37T30A 350. V48M37T45A 1,800. 2,000. 2,500. 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B FR915B FR916A 280B 280B 280B WS33 WS33 WS19 350. V48M37T75A 350. V48M37T12A 350. V48M37T49A 3,400. 4,900. 6,850. 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1422 1600 1581 2400 1905 794 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 280B 280B 275A WS34 WS34 WS35 800. V48M37T22A 800. V48M37T33A 1,360. V48M37T55A 9,100. 11,500. 18,500. Center Tap capacity limited to 5% of rated kVA. Do not include 120 volt lighting tap. Refer to your Cutler-Hammer sales office. Not seismic qualified. Floor mount only. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers General Purpose Transformers 9-16 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0316] Table 9-15. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 380 ∆ Volts 9 3 6 9 15 — — — — 30 45 75 2@-5% 2@-5% 2@-5% 2@-5% 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 74B 74B 74B 74B IndoorOutdoor — — — — Y48G38T03A Y48G38T06A Y48G38T09A Y48G38T15A 1,590. 1,935. 2,505. 3,150. 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 85A 85A 85A IndoorOutdoor — Y48M38T30A — Y48M38T45A — Y48M38T75A 4,600. 5,750. 7,150. 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 FR910A FR912A 281B 281B 281B WS31 WS31 WS31 350. V48M38T15A 350. V48M38T30A 350. V48M38T45A 1,500. 2,000. 2,500. 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B FR915B FR916A 281B 281B 281B WS33 WS33 WS19 350. V48M38T75A 350. V48M38T12A 350. V48M38T49A 3,400. 4,900. 6,850. 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1422 1600 1581 2400 1905 794 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 281B 281B 274B WS34 WS34 WS35 800. V48M38T22A 800. V48M38T33A 1,360. V48M38T55A 9,100. 11,500. 18,500. EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 480 ∆ Volts to 416Y/240 Volts 3 6 9 15 — — — — 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 2@-5% 2@-5% 2@-5% 2@-5% 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 70A 70A 70A 70A IndoorOutdoor — — — — Y48G51T03A Y48G51T06A Y48G51T09A Y48G51T15A 1,590. 1,935. 2,505. 3,150. 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 84E 84E 84E IndoorOutdoor — Y48M51T30A — Y48M51T45A — Y48M51T75A 4,600. 5,750. 7,150. 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 FR910A FR912A 280B 280B 280B WS31 WS31 WS31 350. V48M51T15A 350. V48M51T30A 350. V48M51T45A 2,110. 2,350. 2,940. 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B FR915B FR916A 280B 280B 280B WS33 WS33 WS19 350. V48M51T75A 350. V48M51T12A 350. V48M51T49A 4,000. 5,750. 8,040. 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1422 1600 1581 2400 1905 794 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 280B 280B 275A WS34 WS34 WS35 800. V48M51T22A 800. V48M51T33A 1,360. V48M51T55A 10,680. 13,500. 21,700. EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-15/16 8-5/16 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 IndoorOutdoor — — — — Y48G35T03A Y48G35T06A Y48G35T09A Y48G35T15A 1,590. 1,935. 2,505. 3,150. IndoorOutdoor — Y48M35T30A — Y48M35T45A — Y48M35T75A 4,600. 5,750. 7,150. 480 ∆ Volts to 440Y/254 Volts 3 6 9 15 — — — — 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 26-5/8 26-1/2 32-1/4 25-1/4 28-1/2 30-1/8 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 2@-5% 2@-5% 2@-5% 2@-5% 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201 FR200 FR103 FR95 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 819 638 724 765 324 372 397 191 299 580 FR243 FR244 FR245 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 141 FR909 FR910A FR912A 280B 280B 280B WS31 WS31 WS31 350. V48M35T15A 350. V48M35T30A 350. V48M35T45A 1,800. 2,000. 2,500. 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 664 664 712 486 486 585 218 273 345 FR914B FR915B FR916A 280B 280B 280B WS33 WS33 WS19 350. V48M35T75A 350. V48M35T12A 350. V48M35T49A 3,400. 4,900. 6,850. 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1422 1600 1581 2400 1905 794 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 280B 280B WS34 WS34 WS35 800. V48M35T22A 800. V48M35T33A 1,360. V48M35T55A 9,100. 11,500. 18,500. 84A 84A 84A Floor mount only. Refer to your Cutler-Hammer sales office. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers General Purpose Transformers 9-17 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0317] Table 9-16. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 480Y/277 Volts 9 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 2@-2.5% 2@-2.5% 4@-2.5% 4@-2.5% EPT EPT EPT EPT 115 115 115 115 15-7/8 17-3/8 26-5/8 26-1/2 16-1/2 19-3/4 25-1/4 28-1/2 9-7/8 10-1/2 12-3/4 14-5/8 166 275 422 660 403 441 676 673 419 499 638 723 251 265 323 371 75 124 191 299 FR103 FR95 FR243 FR244 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 25 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 14-1/8 19-1/8 152 230 310 480 635 765 765 1000 511 511 511 663 359 359 359 486 69 104 140 217 FR909 FR910A FR912A FR914B 280B 280B 280B 280B 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% 225 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 1000 760 1171 1100 1422 663 712 793 486 585 616 272 344 499 FR915B FR916A FR917 300 500 750 DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 1581 2400 1905 2900 1905 794 1130 1130 768 914 914 728 FR918A 1088 FR919 1315 FR920 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% — — — — Y48D47T09N Y48D47T15N Y48M47T30N Y48M47T45N 2,170. 2,730. 5,200. 6,500. WS31 WS31 WS31 WS33 350. 350. 350. 350. V48M47T15B V48M47T30N V48M47T45G V48M47T75F 1,830. 2,330. 2,840. 4,010. 280B 280B 280B WS33 WS19 WS34 350. V48M47T12E 350. V48M47T49F 800. V48M47T22F 5,810. 7,290. 10,670. 280B 275A 275A WS34 WS35 WS35 800. V48M47T33E 1,360. V48M47T55F 1,360. V48M47T77A 13,500. 21,600. 35,100. 72C 72C 84D 84D IndoorOutdoor 600 ∆ Volts to 208Y/120 Volts 9 15 30 45 — — 2@+2.5% 2@+2.5% 2@-5% 2@-5% 4@-2.5% 4@-2.5% EPT EPT EPT EPT 115 115 115 115 15-7/8 17-3/8 26-5/8 26-1/2 16-1/2 19-3/4 25-1/4 28-1/2 9-7/8 10-1/2 12-3/4 14-5/8 166 275 422 660 403 441 676 673 419 499 638 723 251 265 323 371 75 124 191 299 FR103 FR95 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 140 FR909 FR910A FR912A 280A 280A 280A 75 2@+2.5% 4@-2.5% 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 712 486 486 585 217 272 344 FR914B FR915B FR916A 225 300 500 DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1422 1600 1581 2400 1905 793 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% Y60G28T09N Y60G28T15N Y60M28T30N Y60M28T45N 2,000. 2,520. 4,800. 6,000. WS31 WS31 WS31 350. V60M28T15A 350. V60M28T30N 350. V60M28T45H 2,390. 2,390. 2,990. 280A 280A 280A WS33 WS33 WS19 350. V60M28T75G 350. V60M28T12F 350. V60M28T49F 4,061. 5,860. 8,190. 280A 280A 275C WS34 WS34 WS35 800. V60M28T22G 800. V60M28T33F 1,360. V60M28T55A 10,870. 13,740. 22,100. — Y60M24T30N — Y60M24T45N 5,000. 6,250. 70B 70B 84B 84B IndoorOutdoor — — — — 600 ∆ Volts to 240 ∆ Volts 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT 115 115 26-5/8 26-1/2 25-1/4 28-1/2 12-3/4 14-5/8 422 660 676 673 638 723 323 371 191 299 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 104 140 FR909 FR910A FR912A 281A 281A 281A WS31 WS31 WS31 350. V60M24T15A 350. V60M24T30A 350. V60M24T45H 2,390. 2,390. 2,990. 75 2@+2.5% 4@-2.5% 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 712 486 486 585 217 272 344 FR914B FR915B FR916A 281A 281A 281A WS33 WS33 WS19 350. V60M24T75G 350. V60M24T12E 350. V60M24T49F 4,061. 5,860. 8,190. 225 300 500 DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1422 1600 1581 2400 1905 793 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 281A 281A 274A WS34 WS34 WS35 800. V60M24T22G 800. V60M24T33F 1,360. V60M24T55A 10,870. 13,740. 22,100. 18-7/8 25 29 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 85B 85B IndoorOutdoor 2400 ∆ Volts to 208Y/120 Volts 3 6 9 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% EPT EPT EPT 115 115 115 10 11 12 6-1/2 7-1/2 8-1/2 115 160 210 254 279 305 479 635 737 165 191 216 52 73 95 FR102 FR97 FR96 65B 65B 65B Recomended Indoor Only — Y42D28T03N Y42D28T06N Y42D28T09N 5,630. 6,450. 8,070. 15 30 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% EPT EPT 115 115 18-1/2 21 10-1/2 27-11/16 20-11/16 12 340 475 470 703 533 525 267 305 154 216 FR195 FR196 65B 65B Recomended Indoor Only — Y42D28T15N — Y42D28T30N 10,200. 13,400. 45 2@+2.5% 2@-2.5% 75 2@+2.5% 2@-2.5% 112.5 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 32-1/2 32-1/2 36 30 30 33 24 24 26 460 620 800 826 902 914 762 762 838 610 610 660 209 282 364 Recomended Indoor Only — V42D28T45G — V42D28T75H — V42D28T12H 7,500. 8,950. 9,450. 150 225 300 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 36 50 51 33 39-3/4 39-3/4 26 37 37 980 914 1450 1270 1620 1010 838 1010 1010 660 940 940 445 659 736 Recomended Indoor Only — V42D28T49K — V42D28T22J — V42D28T33J 11,400. 15,600. 21,000. 500 750 1000 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 59 75 90 48-3/4 44-1/2 69 41 36 42 2400 1238 3300 1905 4500 2286 1238 1130 1753 1041 914 1067 Recomended Indoor Only — V42D28T55G — V42D28T77 — V42D28T11 32,000. 42,000. 52,000. 1091 1498 FR920 2043 FR922 266A 266A No UL label. Contact your local Cutler-Hammer sales office if UL label is required. Refer to your Cutler-Hammer sales office. NEMA 3R enclosure and/or UL label available at an additional cost. Specify at time of order entry if required. Not seismic qualified. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers General Purpose Transformers 9-18 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0318] Table 9-17. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 2400 ∆ Volts to 480Y/277 Volts 45 2@+2.5% 2@-2.5% 75 2@+2.5% 2@-2.5% 112.5 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 32-1/2 32-1/2 36 30 30 33 24 24 26 460 620 800 826 902 914 762 762 838 610 610 660 209 282 364 Recommended Indoor Only — V42D47T45G — V42D47T75F — V42D47T12F 7,500. 8,950. 9,450. 150 225 300 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 36 50 51 33 39-3/4 39-3/4 26 37 37 980 1450 1620 914 1270 1010 838 1010 1010 660 940 940 445 659 736 Recommended Indoor Only — V42D47T49G — V42D47T22H — V42D47T33G 11,400. 15,600. 21,000. 500 750 1000 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 59 48-3/4 41 2400 1238 1238 1041 1091 Recommended Indoor Only — V42D47T55H — V42D47T77 — V42D47T11A 32,000. 42,000. 52,000. 18-7/8 25 29 4160 ∆ Volts to 208Y/120 Volts 3 6 9 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% EPT EPT EPT 115 115 115 10 11 12 6-1/2 7-1/2 8-1/2 115 160 210 254 279 305 479 635 737 165 191 216 52 73 95 FR102 FR97 FR96 65C 65C 65C Recommended Indoor Only — Y46D28T03N — Y46D28T06N — Y46D28T09N 5,800. 6,450. 8,070. 15 30 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% EPT EPT 115 115 18-1/2 21 10-1/2 27-11/16 20-11/16 12 340 475 470 703 533 525 267 305 154 216 FR195 FR196 65C 65C Recommended Indoor Only — Y46D28T15N — Y46D28T30N 10,200. 13,400. 45 75 112.5 150 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 2@-2.5% 2@-2.5% 2@-2.5% 2@-2.5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 32-1/2 32-1/2 36 36 30 30 33 33 24 24 26 26 460 620 800 980 826 902 914 914 762 762 838 838 610 610 660 660 209 282 364 445 Recommended Indoor Only — — — — V46D28T45H V46D28T75H V46D28T12H V46D28T49K 7,500. 8,950. 9,450. 11,400. 225 300 500 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 50 51 59 39-3/4 39-3/4 48-3/4 37 37 41 1450 1620 2400 1270 1010 1238 1010 1010 1238 940 940 1041 659 736 1091 Recommended Indoor Only — V46D28T22J — V46D28T33J — V46D28T55H 15,600. 21,000. 32,000. 750 1000 1500 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 Recommended Indoor Only — V46D28T77 — V46D28T11 — V46D28T14 42,000. 52,000. 65,000. 9 4160 ∆ Volts to 240 ∆ Volts 45 2@+2.5% 2@-2.5% 75 2@+2.5% 2@-2.5% 112.5 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 32-1/2 32-1/2 36 30 30 33 24 24 26 460 620 800 826 902 914 762 762 838 610 610 660 209 282 364 Recommended Indoor Only — V46D24T45F — V46D24T75F — V46D24T12F 7,500. 8,950. 9,450. 150 225 300 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 36 50 51 33 39-3/4 39-3/4 26 37 37 980 1450 1620 914 1270 1010 838 1010 1010 660 940 940 445 659 736 Recommended Indoor Only — V46D24T49H — V46D24T22G — V46D24T33G 11,400. 15,600. 21,000. 500 750 1000 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 59 48-3/4 41 2400 1238 1238 1041 1091 — — Recommended Indoor Only — V46D24T55B — V46D24T77 — V46D24T11A 32,000. 42,000. 52,000. 4160 ∆ Volts to 480Y/277 Volts 45 2@+2.5% 2@-2.5% 75 2@+2.5% 2@-2.5% 112.5 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 32-1/2 32-1/2 36 30 30 33 24 24 26 460 620 800 826 902 914 762 762 838 610 610 660 209 282 364 Recommended Indoor Only — V46D47T45G — V46D47T75G — V46D47T12G 7,500. 8,950. 9,450. 150 225 300 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 36 50 51 33 39-3/4 39-3/4 26 37 37 980 1450 1620 914 1270 1010 838 1010 1010 660 940 940 445 659 736 Recommended Indoor Only — V46D47T49J — V46D47T22H — V46D47T33H 11,400. 15,600. 21,000. 500 750 1000 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 DT-3 150 150 150 59 48-3/4 41 2400 1238 1238 1041 1091 Recommended Indoor Only — V46D47T55H — V46D47T77 — V46D47T11 32,000. 42,000. 52,000. 1500 2@+2.5% 2@-2.5% DT-3 150 — V46D47T14F 65,000. NEMA 3R enclosure and/or UL label available at additional cost. Specify at time of order entry if required. Not seismic qualified. Refer to your Cutler-Hammer sales office. No UL label. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers General Purpose Transformers 9-19 November 2003 Three-Phase, Types EPT, DT-3, 50/60 Hz Vol. 1, Ref. No. [0319] Three-Phase, Types EPT, DT-3, 50/60 Hz Application Description Options and Accessories The basic purpose of a transformer is voltage transformation as near as practically possible to the load for economy and distribution of power. Typical loads for dry-type distribution transformers include lighting, heating, air conditioners, fans and machine tools. Such loads are found in commercial, institutional, industrial and residential structures. Please refer to Page 9-120. Features, Benefits and Functions Type EPT Encapsulated Product Description Type EPT ■ ■ ■ ■ ■ ■ ■ Sand and Resin Encapsulated design. Suitable for indoor or outdoor applications. Totally enclosed, non-ventilated enclosures. Enclosures are NEMA 3R rated. Mountable in any position indoors and upright only outdoors. 185ºC Insulation System, 115ºC rise standard. Available in ratings through 75 kVA and 4160 volts primary. Type DT-3 ■ ■ ■ ■ ■ Ventilated, NEMA 2 enclosure standard. Suitable for indoor applications, outdoors when weathershields are also installed. Upright mounting only. 220ºC Insulation System, 150ºC rise standard. Available in three-phase ratings 15 – 1500 kVA and up to 4160 volts primary. ■ UL listed. ■ 60 Hz operation standard, 50/60 Hz operation available. ■ Short-term overload capability as required by ANSI. ■ Meet NEMA ST-20 sound levels. Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hertz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one hour; and 125% load for four hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Seismically Qualified Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers General Purpose Transformers 9-20 November 2003 Three-Phase, Types EPT, DT-3, 50/60 Hz Insulation System and Temperature Rise Sound Levels Series-Multiple Windings Industry standards classify insulation systems and rise as shown below: All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Table 9-18. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. 9 Vol. 1, Ref. No. [0320] Enclosures Eaton’s Cutler-Hammer ventilated transformers, Type DT-3, utilize a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Cutler-Hammer encapsulated transformers, Type EPT, utilize a NEMA 3R rated enclosure as standard. Table 9-19. Average Sound Levels NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Technical Data and Specifications Please refer to Page 9-122. Applies to general purpose ventilated transformers only. Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Ventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose Transformers 9-21 November 2003 Three-Phase, Types EPT, DT-3, 50/60 Hz Vol. 1, Ref. No. [0321] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-20. Three-Phase Selection Information — Types EPT, DT-3, 50/60 Hz Note: For 50/60 Hz single-phase transformers contact your local Cutler-Hammer sales office. kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Frame Wiring Weathershield Style Lbs. H kg Diagram Catalog Price Number W D Number Number U.S. $ Price U.S. $ 380 ∆ Volts to 208Y/120 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 165 190 275 403 403 442 419 419 500 251 251 265 75 FR200 86 FR103 125 FR95 70D 70D 70D IndoorOutdoor — Y38G28T03X — Y38G28T06X — Y38G28T09X 1,600. 1,950. 2,525. 70D 84W 84W IndoorOutdoor — Y38G28T15X — Y38M28T30X — Y38M28T45X 3,175. 5,800. 7,250. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 FR96 223 FR243 359 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 765 310 765 480 1000 511 511 664 359 359 486 104 FR910A 141 FR912A 218 FR914B 280L 280L 280L WS31 WS31 WS33 350. V38M28T15X 350. V38M28T30X 350. V38M28T45X 2,260. 2,520. 3,150. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 30-1/4 600 1000 760 1171 1100 1422 664 712 794 486 585 616 273 FR915B 345 FR916A 499 FR917 280L 280L 280L WS33 WS19 WS34 350. V38M28T75X 350. V38M28T12X 800. V38M28T49X 4,280. 6,170. 9,100. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 1581 2400 1905 2900 1905 794 1130 1130 768 914 914 728 FR918A 1088 FR919 1315 FR920 280L 280L WS34 WS35 WS35 800. V38M28T22X 1,360. V38M28T33X 1,360. V38M28T55X 11,500. 18,300. 23,100. 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 380 ∆ Volts to 220Y/127 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 165 190 275 403 403 442 419 419 500 251 251 265 75 FR200 86 FR103 125 FR95 70F 70F 70F IndoorOutdoor — Y38G31T03X — Y38G31T06X — Y38G31T09X 1,540. 1,860. 2,420. 70F 84H 84H IndoorOutdoor — Y38G31T15X — Y38M31T30X — Y38M31T45X 3,040. 5,800. 7,250. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 FR96 223 FR243 359 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 765 310 765 480 1000 511 511 664 359 359 486 104 FR910A 141 FR912A 218 FR914B 280L 280L 280L WS31 WS31 WS33 350. V38M31T15X 350. V38M31T30X 350. V38M31T45X 2,270. 2,520. 3,150. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 1000 760 1171 1100 1422 664 712 794 486 585 616 273 FR915B 345 FR916A 499 FR917 280L 280L 280L WS33 WS19 WS34 350. V38M31T75X 350. V38M31T12X 800. V38M31T49X 4,300. 6,170. 8,570. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 1581 2400 1905 2900 1905 794 1130 1130 768 914 914 728 FR918A 1088 FR919 1315 FR920 280L 275H 275H WS34 WS35 WS35 800. V38M31T22X 1,360. V38M31T33X 1,360. V38M31T55X 11,375. 18,300. 23,100. 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 380 ∆ Volts to 380Y/220 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 165 190 275 403 403 442 419 419 500 251 251 265 75 FR200 86 FR103 125 FR95 70D 70D 70D IndoorOutdoor — Y38G37T03X — Y38G37T06X — Y38G37T09X 1,740. 2,100. 2,740. 70D 84H 84H IndoorOutdoor — Y38G37T15X — Y38M37T30X — Y38M37T45X 3,440. 6,550. 8,190. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 FR96 223 FR243 359 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 765 310 765 480 1000 511 511 664 359 359 486 104 FR910A 141 FR912A 218 FR914B 280L 280L 280L WS31 WS31 WS33 350. V38M37T15X 350. V38M37T30X 350. V38M37T45X 2,380. 3,040. 3,700. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 1000 760 1171 1100 1422 664 712 794 486 585 616 273 FR915B 345 FR916A 499 FR917 280L 280L 280L WS33 WS19 WS34 350. V38M37T75X 350. V38M37T12X 800. V38M37T49X 5,240. 7,580. 9,525. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 1581 2400 1905 2900 1905 794 1130 1130 768 914 914 728 FR918A 1088 FR919 1315 FR920 280L 280L WS34 WS35 WS35 800. V38M37T22X 1,360. V38M37T33X 1,360. V38M37T55X 13,930. 17,640. 28,220. Refer to your Cutler-Hammer sales office. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers General Purpose Transformers 9-22 November 2003 Three-Phase, Types EPT, DT-3, 50/60 Hz Vol. 1, Ref. No. [0322] Table 9-21. Three-Phase Selection Information — Types EPT, DT-3, 50/60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 380 ∆ Volts to 416Y/240 Volts, 50/60 Hz 3 6 9 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 165 190 275 403 403 442 419 419 500 251 251 265 75 86 125 FR200 FR103 FR95 IndoorOutdoor — Y38G51T03X — Y38G51T06X — Y38G51T09X 1,685. 2,440. 3,160. — Y38G51T15X — Y38M51T30X — Y38M51T45X 3,970. 7,560. 9,450. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 223 359 FR96 FR243 FR244 IndoorOutdoor 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 765 310 765 480 1000 511 511 664 359 359 486 104 141 218 FR910A FR912A FR914B 280L 280L 280L WS31 WS31 WS33 350. V38M51T15X 350. V38M51T30X 350. V38M51T45X 2,360. 3,020. 3,675. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 1000 760 1171 1100 1422 664 712 794 486 585 616 273 345 499 FR915B FR916A FR917 280L 280L 280L WS33 WS19 WS34 350. V38M51T75X 350. V38M51T12X 800. V38M51T49X 5,200. 7,525. 9,450. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 1581 2400 1905 2900 1905 794 1130 1130 768 914 914 728 1088 1315 FR918A FR919 FR920 280L WS34 WS35 WS35 800. V38M51T22X 1,360. V38M51T33X 1,360. V38M51T55X 13,820. 17,500. 28,000. 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 400 ∆ Volts to 208Y/120 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 165 190 275 403 403 442 419 419 500 251 251 265 75 86 125 FR200 FR103 FR95 66E 66E 66E IndoorOutdoor — Y39G28T03X — Y39G28T06X — Y39G28T09X 1,540. 1,860. 2,525. 66E 84Z 84Z IndoorOutdoor — Y39G28T15X — Y39M28T30X — Y39M28T45X 3,175. 5,200. 7,250. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 223 359 FR96 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 765 310 765 480 1000 511 511 664 359 359 486 104 141 218 FR910A FR912A FR914B 280K 280K 280K WS31 WS31 WS33 350. V39M28T15X 350. V39M28T30X 350. V39M28T45X 2,380. 3,040. 3,700. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 1000 760 1171 1100 1422 664 712 794 486 585 616 273 345 499 FR915B FR916A FR917 280K 280K 280K WS33 WS19 WS34 350. V39M28T75X 350. V39M28T12X 800. V39M28T49X 5,230. 7,570. 9,500. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 1581 2400 1905 2900 1905 794 1130 1130 768 914 914 728 1088 1315 FR918A FR919 FR920 280K WS34 WS35 WS35 800. V39M28T22X 1,360. V39M28T33X 1,360. V39M28T55X 13,900. 17,600. 28,160. 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 400 ∆ Volts to 400Y/231 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 165 190 275 403 403 442 419 419 500 251 251 265 75 86 125 FR200 FR103 FR95 70U 70U 70U IndoorOutdoor — Y39G34T03X — Y39G34T06X — Y39G34T09X 1,740. 2,100. 2,740. 70U 84V 84V IndoorOutdoor — Y39G34T15X — Y39M34T30X — Y39M34T45X 3,440. 5,200. 7,250. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 223 359 FR96 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 765 310 765 480 1000 511 511 664 359 359 486 104 141 218 FR910A FR912A FR914B 280K 280K 280K WS31 WS31 WS33 350. V39M34T15X 350. V39M34T30X 350. V39M34T45X 2,380. 3,040. 3,700. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 1000 760 1171 1100 1422 664 712 794 486 585 616 273 345 499 FR915B FR916A FR917 280K 280K 280K WS33 WS19 WS34 350. V39M34T75X 350. V39M34T12X 800. V39M34T49X 5,230. 7,570. 9,500. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 1581 2400 1905 2900 1905 794 1130 1130 768 914 914 728 1088 1315 FR918A FR919 FR920 280K WS34 WS35 WS35 800. V39M34T22X 1,360. V39M34T33X 1,360. V39M34T55X 13,900. 17,600. 28,160. Refer to your Cutler-Hammer sales office. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers General Purpose Transformers 9-23 November 2003 Three-Phase, Types EPT, DT-3, 50/60 Hz Vol. 1, Ref. No. [0323] Table 9-22. Three-Phase Selection Information — Types EPT, DT-3, 50/60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Frame Lbs. H kg W D Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 416 ∆ Volts to 208Y/120 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 165 190 275 403 403 442 419 419 500 251 251 265 75 FR200 86 FR103 125 FR95 70V 70V 70V IndoorOutdoor — Y43G28T03X — Y43G28T06X — Y43G28T09X 1,600. 1,950. 2,525. 70V 84I 84I IndoorOutdoor — Y43G28T15X — Y43M28T30X — Y43M28T45X 3,175. 5,800. 7,250. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 FR96 223 FR243 359 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 664 359 359 486 104 FR910A 141 FR912A 218 FR914B 280P 280P 280P WS31 WS31 WS33 350. V43M28T15X 350. V43M28T30X 350. V43M28T45X 2,260. 2,520. 3,150. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 664 712 794 486 585 616 273 FR915B 345 FR916A 499 FR917 280P 280P 280P WS33 WS19 WS34 350. V43M28T75X 350. V43M28T12X 800. V43M28T49X 4,570. 6,230. 8,570. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2400 2900 1581 1905 1905 794 1130 1130 768 914 914 728 FR918A 1088 FR919 1315 FR920 280P WS34 WS35 WS35 800. V43M28T22X 1,360. V43M28T33X 1,360. V43M28T55X 11,450. 18,300. 23,400. 416 ∆ Volts to 220 ∆ Volts With 110 Volt Lighting Tap on B Phase, 50/60 Hz 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 664 359 359 486 104 FR910A 141 FR912A 218 FR914B 282J 282J 282J WS31 WS31 WS33 350. V43M26T15X 350. V43M26T30X 350. V43M26T45X 1,960. 2,520. 3,045. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 664 712 794 486 585 616 273 FR915B 345 FR916A 499 FR917 282J 282J 282J WS33 WS19 WS34 350. V43M26T75X 350. V43M26T12X 800. V43M26T49X 4,310. 6,235. 7,830. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2400 2900 1581 1905 1905 794 1130 1130 768 914 914 728 FR918A 1088 FR919 1315 FR920 282J WS34 WS35 WS35 800. V43M26T22X 1,360. V43M26T33X 1,360. V43M26T55X 11,450. 14,500. 23,200. 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 165 190 275 403 403 442 419 419 500 251 251 265 75 FR200 86 FR103 125 FR95 416 ∆ Volts to 220Y/127 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 70V 70V 70V IndoorOutdoor — Y43G31T03X — Y43G31T06X — Y43G31T09X 1,550. 1,890. 2,340. 70V IndoorOutdoor — Y43G31T15X — Y43M31T30X — Y43M31T45X 3,050. 5,800. 7,250. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 FR96 223 FR243 359 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 664 359 359 486 104 FR910A 141 FR912A 218 FR914B 280S 280S 280S WS31 WS31 WS33 350. V43M31T15X 350. V43M31T30X 350. V43M31T45X 2,260. 2,520. 3,150. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 664 712 794 486 585 616 273 FR915B 345 FR916A 499 FR917 280S 280S 280S WS33 WS19 WS34 350. V43M31T75X 350. V43M31T12X 800. V43M31T49X 4,570. 6,230. 8,570. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2400 2900 1581 1905 1905 794 1130 1130 768 914 914 728 FR918A 1088 FR919 1315 FR920 280S WS34 WS35 WS35 800. V43M31T22X 1,360. V43M31T33X 1,360. V43M31T55X 11,450. 18,300. 23,400. EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 165 190 275 403 403 442 419 419 500 251 251 265 75 FR200 86 FR103 125 FR95 416 ∆ Volts to 240 ∆ Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% 74I 74I 74I IndoorOutdoor — Y43G24T03X — Y43G24T06X — Y43G24T09X 1,550. 1,890. 2,430. 74I IndoorOutdoor — Y43G24T15X — Y43M24T30X — Y43M24T45X 3,060. 5,820. 7,280. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 FR96 223 FR243 359 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 664 359 359 486 104 FR910A 141 FR912A 218 FR914B 281AD 281AD 281AD WS31 WS31 WS33 350. V43M24T15X 350. V43M24T30X 350. V43M24T45X 1,960. 2,520. 3,045. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 664 712 794 486 585 616 273 FR915B 345 FR916A 499 FR917 281AD 281AD 281AD WS33 WS19 WS34 350. V43M24T75X 350. V43M24T12X 800. V43M24T49X 4,310. 6,235. 7,830. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2400 2900 1581 1905 1905 794 1130 1130 768 914 914 728 FR918A 1088 FR919 1315 FR920 281AD WS34 WS35 WS35 800. V43M24T22X 1,360. V43M24T33X 1,360. V43M24T55X 11,450. 14,500. 23,200. Refer to your Cutler-Hammer sales office. Center Tap capacity limited to 5% of rated kVA. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers General Purpose Transformers 9-24 November 2003 Three-Phase, Types EPT, DT-3, 50/60 Hz Vol. 1, Ref. No. [0324] Table 9-23. Three-Phase Selection Information — Types EPT, DT-3, 50/60 Hz kVA Full Cap. Taps FCAN FCBN Dimensions (Inches) Type °C Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Weathershield Style Wiring Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 416 ∆ Volts to 416Y/240 Volts, 50/60 Hz 3 6 9 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 165 190 275 403 403 442 419 419 500 251 251 265 75 86 125 FR200 FR103 FR95 66F 66F 66F IndoorOutdoor — Y43G51T03X — Y43G51T06X — Y43G51T09X 1,550. 1,890. 2,340. 66F 84J 84J IndoorOutdoor — Y43G51T15X — Y43M51T30X — Y43M51T45X 3,050. 5,800. 7,250. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 223 359 FR195 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 664 359 359 486 104 141 218 FR910A FR912A FR914B 280S 280S 280S WS31 WS31 WS33 350. V43M51T15X 350. V43M51T30X 350. V43M51T45X 2,110. 2,350. 2,940. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 664 712 794 486 585 616 273 345 499 FR915B FR916A FR917 280S 280S 280S WS33 WS19 WS34 350. V43M51T75X 350. V43M51T12X 800. V43M51T49X 4,260. 5,800. 7,980. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2400 2900 1581 1905 1905 794 1130 1130 768 914 914 728 1088 1315 FR918A FR919 FR920 280S 275N 275N WS34 WS35 WS35 800. V43M51T22X 1,360. V43M51T33X 1,360. V43M51T55X 10,660. 17,040. 21,790. 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 165 190 275 403 403 442 419 419 500 251 251 265 75 86 125 FR200 FR103 FR95 70A 70A 70A IndoorOutdoor — Y48G28T03X — Y48G28T06X — Y48G28T09X 1,340. 1,630. 2,110. 70A 84A 84A IndoorOutdoor — Y48G28T15X — Y48M28T30X — Y48M28T45X 2,650. 5,200. 6,500. 480 ∆ Volts to 208Y/120 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 223 359 FR96 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 664 359 359 486 104 141 218 FR910A FR912A FR914B 280B 280B 280B WS31 WS31 WS33 350. V48M28T15X 350. V48M28T30X 350. V48M28T45X 1,720. 2,175. 2,650. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 664 712 794 486 585 616 273 345 499 FR915B FR916A FR917 280B 280B 280B WS33 WS19 WS34 350. V48M28T75X 350. V48M28T12X 800. V48M28T49X 3,750. 6,170. 6,810. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2400 2900 1581 1905 1905 794 1130 1130 768 914 914 728 1088 1315 FR918A FR919 FR920 280B 275A 275A WS34 WS35 WS35 800. V48M28T22X 1,360. V48M28T33X 1,360. V48M28T55X 9,900. 12,800. 20,160. 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 165 190 275 403 403 442 419 419 500 251 251 265 75 86 125 FR200 FR103 FR95 70A 70A 70A IndoorOutdoor — Y48G31T03X — Y48G31T06X — Y48G31T09X 2,000. 2,440. 3,160. 70A 84K 84K IndoorOutdoor — Y48G31T15X — Y48M31T30X — Y48M31T45X 3,970. 5,800. 7,250. 480 ∆ Volts to 220Y/127 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 223 359 FR96 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 664 359 359 486 104 141 218 FR910A FR912A FR914B 280B 280B 280B WS31 WS31 WS33 350. V48M31T15X 350. V48M31T30X 350. V48M31T45X 1,960. 2,520. 3,060. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 664 712 794 486 585 616 273 345 499 FR915B FR916A FR917 280B 280B 280B WS33 WS19 WS34 350. V48M31T75X 350. V48M31T12X 800. V48M31T49X 4,310. 6,230. 7,850. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2400 2900 1581 1905 1905 794 1130 1130 768 914 914 728 1088 1315 FR918A FR919 FR920 280B 275A 275A WS34 WS35 WS35 800. V48M31T22X 1,360. V48M31T33X 1,360. V48M31T55X 11,375. 14,500. 23,100. 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 165 190 275 403 403 442 419 419 500 251 251 265 75 86 125 FR200 FR103 FR95 480 ∆ Volts to 380Y/220 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 70R 70R 70R IndoorOutdoor — Y48G37T03X — Y48G37T06X — Y48G37T09X 2,000. 2,440. 3,160. 70R 70R IndoorOutdoor — Y48G37T15X — Y48M37T30X — Y48M37T45X 3,970. 5,800. 7,250. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 223 359 FR96 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 664 359 359 486 104 141 218 FR910A FR912A FR914B 280B 280B 280B WS31 WS31 WS33 350. V48M37T15X 350. V48M37T30X 350. V48M37T45X 2,270. 2,520. 3,150. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 664 712 794 486 585 616 273 345 499 FR915B FR916A FR917 280B 280B 280B WS33 WS19 WS34 350. V48M37T75X 350. V48M37T12X 800. V48M37T49X 4,300. 6,175. 8,570. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2400 2900 1581 1905 1905 794 1130 1130 768 914 914 728 1088 1315 FR918A FR919 FR920 280B 275A 275A WS34 WS35 WS35 800. V48M37T22X 1,360. V48M37T33X 1,360. V48M37T55X 11,375. 18,300. 23,100. Refer to your Cutler-Hammer sales office. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers General Purpose Transformers 9-25 November 2003 Three-Phase, Types EPT, DT-3, 50/60 Hz Vol. 1, Ref. No. [0325] Table 9-24. Three-Phase Selection Information — Types EPT, DT-3, 50/60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Lbs. H W D Wt. kg Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 400Y/231 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 165 190 275 403 403 442 419 419 500 251 251 265 75 86 125 FR200 FR103 FR95 70A 70A 70A IndoorOutdoor — Y48G34T03X — Y48G34T06X — Y48G34T09X 2,000. 2,440. 3,160. 70A IndoorOutdoor — Y48G34T15X — Y48M34T30X — Y48M34T45X 3,970. 5,800. 7,250. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 223 359 FR96 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 765 310 765 480 1000 511 511 664 359 359 486 104 141 218 FR910A FR912A FR914B 280B 280B 280B WS31 WS31 WS33 350. V48M34T15X 350. V48M34T30X 350. V48M34T45X 2,270. 2,520. 3,150. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 1000 760 1171 1100 1422 664 712 794 486 585 616 273 345 499 FR915B FR916A FR917 280B 280B 280B WS33 WS19 WS34 350. V48M34T75X 350. V48M34T12X 800. V48M34T49X 4,300. 6,170. 8,570. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 1581 2400 1905 2900 1905 794 1130 1130 768 914 914 280B WS34 WS35 WS35 800. V48M34T22X 1,360. V48M34T33X 1,360. V48M34T55X 11,375. 14,375. 23,050. 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 728 FR918A 1089 FR919 1315 FR920 480 ∆ Volts to 480Y/277 Volts, 50/60 Hz 3 6 9 — — — 2@-5% 2@-5% 2@-5% EPT EPT EPT 115 115 115 15-7/8 15-7/8 17-3/8 165 190 275 403 403 442 419 419 500 251 251 265 75 86 125 FR200 FR103 FR95 70L 70L 70L IndoorOutdoor — Y48G47T03X — Y48G47T06X — Y48G47T09X 2,000. 2,440. 3,160. 70L 84D 84D IndoorOutdoor — Y48G47T15X — Y48M47T30X — Y48M47T45X 3,970. 6,550. 8,190. 15 30 45 — 2@-5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% EPT EPT EPT 115 115 115 15-15/16 25-3/4 26-5/8 25-1/4 26-1/2 28-1/2 8-3/8 12-3/4 14-5/8 350 490 790 405 676 673 654 638 724 213 324 372 159 223 359 FR96 FR243 FR244 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 765 310 765 480 1000 511 511 664 359 359 486 104 141 218 FR910A FR912A FR914B 280B 280B 280B WS31 WS31 WS33 350. V48M47T15X 350. V48M47T30X 350. V48M47T45X 2,305. 2,935. 3,575. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 1000 760 1171 1100 1422 664 712 794 486 585 616 273 345 499 FR915B FR916A FR917 280B 280B 280B WS33 WS19 WS34 350. V48M47T75X 350. V48M47T12X 800. V48M47T49X 5,050. 7,320. 9,180. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 1581 2400 1905 2900 1905 794 1130 1130 768 914 914 728 FR918A 1089 FR919 1315 FR920 280B 275A 275A WS34 WS35 WS35 800. V48M47T22X 1,360. V48M47T33X 1,360. V48M47T55X 13,440. 17,000. 27,200. Refer to your Cutler-Hammer sales office. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Electrostatically Shielded Transformers 9-26 November 2003 Single- and Three-Phase Types EP, DS-3, EPT, DT-3, 60 Hz Single- and Three-Phase, Types EP, DS-3, EPT, DT-3, 60 Hz Type DT-3 9 Product Description Types EP, EPT ■ ■ ■ ■ ■ ■ ■ ■ Sand and Resin Encapsulated design. Suitable for indoor or outdoor applications. Totally enclosed, non-ventilated enclosures. Enclosures are NEMA 3R rated. Mountable in any position indoors and upright only outdoors. 185ºC Insulation System, 115ºC rise standard. Available in single-phase ratings through 37.5 kVA and 4160 volts primary (EP). Available in three-phase ratings through 75 kVA and 4160 volts primary (EPT). Types DS-3, DT-3 ■ ■ ■ ■ ■ ■ Ventilated, NEMA 2 enclosure standard. Suitable for indoor applications, outdoors when weathershields are also installed. Upright mounting only. 220ºC Insulation System, 150ºC rise standard. Available in single-phase ratings 15 – 167 kVA and up to 4160 volts primary (DS-3). Available in three-phase ratings 15 – 1500 kVA and up to 4160 volts primary (DT-3). Vol. 1, Ref. No. [0326] Application Description Options and Accessories Electrostatically shielded transformers are used to protect sensitive electrical equipment from undesirable high frequency signals commonly generated by lighting, switching surges, motors, and SCRs feeding noise back into the line. An electrostatic shield, consisting of a single turn of aluminum foil placed between the primary and secondary winding, is used to provide from 30 to 70 dB attenuation of wide band line-to-ground (common mode) noise. Please refer to Page 9-120. Typical uses of shielded isolation transformers include: Overload Capability ■ Suppression of transients and noise which travels from its source to the sensitive load equipment. ■ Suppression of noise and transients at the point where the noise or transients are originating, thus preventing them from backfeeding from the source to the feeders. ■ Transform one voltage level to another. ■ Isolate one circuit from another. Features, Benefits and Functions ■ UL listed. ■ 60 Hz operation standard, 50/60 Hz operation available. ■ Short-term overload capability as required by ANSI. ■ Meet NEMA ST-20 sound levels. Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. For more information visit: www.cutler-hammer.eaton.com Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hertz operation. Transformers required for other frequencies are available and must be specifically designed. Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one hour; and 125% load for four hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-25. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Cutler-Hammer ventilated transformers, Types DS-3 and DT-3 utilize a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Cutler-Hammer encapsulated transformers, Types EP and EPT, utilize a NEMA 3R rated enclosure as standard. CA08101001E Transformers Electrostatically Shielded Transformers 9-27 November 2003 Single- and Three-Phase, Types EP, 60 Hz Vol. 1, Ref. No. [0327] Sound Levels Series-Multiple Windings Table 9-26. Average Sound Levels All Eaton’s Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. NEMA ST-20 Average Sound Level in dB kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Ventilated transformers have leads brought out to aluminum pads that are predrilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Technical Data and Specifications Please refer to Page 9-122. Product Selection Additional Product Selection information begins on Page 9-136. Table 9-27. Single-Phase Selection Information — Types EP, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Lbs. H W D Wt. kg Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 120 x 240 Volts to 120/240 Volts 3 5 7.5 10 15 25 — — — — — — EP EP EP 115 115 115 14-1/8 7-3/4 16 10-3/8 16 10-3/8 8 9-7/8 9-7/8 65 113 123 359 406 406 197 263 263 203 251 251 29 51 55 FR176 FR177 FR178 90B 90B 90B IndoorOutdoor — S10N11E03N — S10N11E05N — S10N11E07N 1,155. 1,560. 2,010. — — — — — — EP EP EP 115 115 115 19 13-3/8 10-1/2 193 19 13-3/8 10-1/2 216 22-3/8 16-3/8 14-1/8 375 482 482 568 339 339 416 266 266 359 87 98 170 FR179 FR180 FR182 90B 90B 90B IndoorOutdoor — S10N11E10N — S10N11E15N — S10N11E25N 2,450. 3,350. 4,800. 120 Volts to 120 Volts 3 5 7.5 10 15 25 — — — — — — EP EP EP 115 115 115 14-1/8 7-3/4 16 10-3/8 16 10-3/8 8 9-7/8 9-7/8 65 113 123 359 406 406 197 263 263 203 251 251 29 51 55 FR176 FR177 FR178 77A 77A 77A IndoorOutdoor — S12N12E03N — S12N12E05N — S12N12E07N 1,155. 1,560. 2,010. — — — — — — EP EP EP 115 115 115 19 13-3/8 10-1/2 193 19 13-3/8 10-1/2 216 22-3/8 16-3/8 14-1/8 375 482 482 568 339 339 416 266 266 359 87 98 170 FR179 FR180 FR182 77A 77A 77A IndoorOutdoor — S12N12E10N — S12N12E15N — S12N12E25N 2,450. 3,350. 4,800. 208 Volts to 120/240 Volts 3 5 7.5 10 15 25 — — — — — — EP EP EP 115 115 115 14-1/8 7-3/4 16 10-3/8 16 10-3/8 8 9-7/8 9-7/8 65 113 123 359 406 406 197 263 263 203 251 251 29 51 55 FR176 FR177 FR178 578A 578A 578A IndoorOutdoor — S29N11E03N — S29N11E05N — S29N11E07N 1,320. 1,950. 2,585. — — — — — — EP EP EP 115 115 115 19 13-3/8 10-1/2 193 19 13-3/8 10-1/2 216 22-3/8 16-3/8 14-1/8 375 482 482 568 339 339 416 266 266 359 87 98 170 FR179 FR180 FR182 578A 578A 578A IndoorOutdoor — S29N11E10N — S29N11E15N — S29N11E25N 3,100. 3,650. 5,200. 208 Volts to 208 Volts 3 5 7.5 10 15 25 — — — — — — EP EP EP 115 115 115 14-1/8 7-3/4 16 10-3/8 16 10-3/8 8 9-7/8 9-7/8 65 113 123 359 406 406 197 263 263 203 251 251 29 51 55 FR176 FR177 FR178 77B 77B 77B IndoorOutdoor — S29N29E03N — S29N29E05N — S29N29E07N 1,320. 1,950. 2,585. — — — — — — EP EP EP 115 115 115 19 13-3/8 10-1/2 193 19 13-3/8 10-1/2 216 22-3/8 16-3/8 14-1/8 375 482 482 568 339 339 416 266 266 359 87 98 170 FR179 FR180 FR182 77B 77B 77B IndoorOutdoor — S29N29E10N — S29N29E15N — S29N29E25N 3,100. 3,350. 5,200. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Electrostatically Shielded Transformers 9-28 November 2003 Single-Phase, Types EP, DS-3, 60 Hz Vol. 1, Ref. No. [0328] Table 9-28. Single-Phase Selection Information — Types EP, DS-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Lbs. H W D Wt. kg Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 240 Volts to 240 Volts 3 5 7.5 10 15 25 — — — — — — EP EP EP 115 115 115 14-1/8 7-3/4 16 10-3/8 16 10-3/8 8 65 9-7/8 113 9-7/8 123 359 406 406 197 263 263 203 251 251 29 51 55 FR176 FR177 FR178 77C 77C 77C IndoorOutdoor — S24N24E03N 1,155. — S24N24E05N 1,560. — S24N24E07N 2,010. — — — — — — EP EP EP 115 115 115 19 13-3/8 19 13-3/8 22-3/8 16-3/8 10-1/2 193 10-1/2 216 14-1/8 375 482 482 568 339 339 416 266 266 359 87 98 170 FR179 FR180 FR182 77C 77C 77C IndoorOutdoor — S24N24E10N 2,450. — S24N24E15N 3,350. — S24N24E25N 4,800. 277 Volts to 120/240 Volts 3 5 7.5 10 15 25 9 — — — — — — EP EP EP 115 115 115 14-1/8 7-3/4 16 10-3/8 16 10-3/8 8 65 9-7/8 113 9-7/8 123 359 406 406 197 263 263 203 251 251 29 51 55 FR176 513B FR177 513B FR178 513B IndoorOutdoor — S27N11E03N 1,320. — S27N11E05N 1,950. — S27N11E07N 2,585. — — — — — — EP EP EP 115 115 115 19 13-3/8 19 13-3/8 22-3/8 16-3/8 10-1/2 193 10-1/2 216 14-1/8 375 482 482 568 339 339 416 266 266 359 87 98 170 FR179 513B FR180 513B FR182 513B IndoorOutdoor — S27N11E10N 3,100. — S27N11E15N 3,650. — S27N11E25N 5,200. 240 x 480 Volts to 120/240 Volts .25 — .50 — .75 — EP EP EP 115 115 115 6-1/2 6-1/2 8-3/8 4-7/8 4-7/8 6 3-7/8 4-5/8 5-3/4 12 13 21 165 165 213 124 124 152 98 117 146 5 6 10 FR56 FR57 FR58A 90A 90A 90A IndoorOutdoor — S20N11E26A — S20N11E51A — S20N11E76A 150. 190. 245. 6 6-3/16 6-3/16 5-3/4 6-1/8 6-1/8 31 40 40 213 273 273 152 157 157 146 156 156 14 18 18 FR59A FR67 FR68 90A 90A 90A IndoorOutdoor — S20N11E01A — S20N11E16A — S20N11E02A 290. 355. 450. 8 65 9-7/8 113 9-7/8 123 359 406 406 195 263 263 203 251 251 29 51 55 FR176 FR177 FR178 90A 90A 90A IndoorOutdoor — S20N11E03A — S20N11E05A — S20N11E07A 550. 815. 1,080. — S20N11E10A — S20N11E15A — S20L11E25A 1,300. 1,750. 2,475. 1 1.5 2 — — — — — — EP EP EP 115 115 115 8-3/8 10-3/4 10-3/4 3 5 7.5 — — — — — — EP EP EP 115 115 115 14-1/8 7-11/16 16 10-3/8 16 10-3/8 10 15 25 — — — — EP EP EP 115 115 115 19 13-3/8 19 13-3/8 22-3/8 16-3/8 10-1/2 193 10-1/2 216 14-1/8 375 482 482 568 339 339 416 266 266 359 87 98 170 FR179 90A FR180 90A FR182 526A IndoorOutdoor 15 25 37.5 DS-3 150 DS-3 150 DS-3 150 30-1/4 16-7/8 31-1/4 22-5/8 37-5/8 22-5/8 15-7/8 147 17-1/2 212 19-1/2 306 768 793 953 428 574 574 402 445 495 67 96 139 FR815 261A FR816 261A FR817 261A WS15 WS11 WS11 350. T20P11E15 350. T20P11E25 350. T20P11E37 1,600. 2,075. 2,540. DS-3 150 DS-3 150 DS-3 150 37-5/8 22-5/8 42-1/8 24 42-1/8 24 19-1/2 340 23-3/8 510 23-3/8 600 953 1070 1070 574 610 610 495 594 594 154 233 274 FR818 261A FR819 261A FR820 261A WS11 WS16 WS16 350. T20P11E50 800. T20P11E75 800. T20P11E99 3,080. 4,350. 5,400. 50 75 100 — — — 2@+5% FCBN at 240 volts; 4@-2.5% FCBN at 480 volts. 1@+5%, 2@-5% at 240 volts primary; 2@+2.5%, 4@-2.5% at 480 volts primary. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Electrostatically Shielded Transformers 9-29 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0329] Table 9-29. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Frame Lbs. H kg W D Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 208 ∆ Volts to 208Y/120 Volts 15 2@+2.5% 2@-2.5% EPT 115 17-3/8 19-3/4 10-1/2 275 441 502 266 124 FR95 15 30 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 150 150 25 30-1/8 20-1/8 20-1/8 14-1/8 14-1/8 152 230 635 765 511 511 359 359 69 FR909 104 FR910A 45 2@+2.5% 4@-2.5% 75 2@+2.5% 4@-2.5% 112.5 1@+5% 2@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 310 480 600 765 1000 1000 511 663 663 359 485 485 150 225 300 DT-3 DT-3 DT-3 150 150 150 46-1/8 62-1/4 62-1/4 28 31-1/4 31-1/4 23 30-1/4 30-1/4 760 1600 1600 1171 1581 1581 712 794 794 585 768 768 1@+5% 1@+5% 1@+5% 2@-5% 2@-5% 2@-5% 86A 283A 283A IndoorOutdoor WS31 WS31 — — 350. 350. Y29D28E15B — V29M28E15A V29M28E30B 2,950. — 2,080. 2,660. 140 FR912A 217 FR914B 272 FR915B 283A 283A 287A WS31 WS33 WS33 350. V29M28E45B 350. V29M28E75B 350. V29R28E12B 3,235. 4,575. 6,620. 344 FR916A 728 FR918A 728 FR918A 287A 287A 287A WS19 WS34 WS34 350. V29R28E49B 800. V29R28E22B 800. V29R28E33B 8,300. 12,100. 15,400. 480 ∆ Volts to 208Y/120 Volts 3 6 9 15 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 2@-2.5% 2@-2.5% 2@-2.5% 2@-2.5% EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 15-5/16 16-1/2 16-1/2 19-3/4 8-5/16 9-7/8 9-7/8 10-1/2 116 143 166 275 339 403 403 441 404 419 419 419 211 251 251 251 Y48D28E03A Y48D28E06A Y48D28E09N Y48D28E15B 1,165. 1,420. 1,840. 2,310. 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 239 310 635 765 765 511 511 511 359 359 359 69 FR909 108 FR910A 140 FR912A 283B 283B 283B WS31 WS31 WS31 350. V48M28E15B 350. V48M28E30B 350. V48M28E45B 1,485. 1,900. 2,310. 75 2@+2.5% 4@-2.5% 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 712 485 485 585 217 FR914B 272 FR915B 344 FR916A 283B 283B 283B WS33 WS33 WS19 350. V48M28E75B 350. V48M28E12B 350. V48M28E49B 3,270. 4,945. 6,200. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 793 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 283B 283B 292A WS34 WS34 WS35 800. V48M28E22B 800. V48M28E33B 1,360. V48M28E55G 9,000. 11,500. 18,400. 750 1000 2@+2.5% 4@-2.5% 1@+3.5% 1@-3.5% DT-3 DT-3 150 150 75 68 44-1/2 64 36 45 2900 4350 1905 1727 1130 1625 914 1143 1315 FR920 1912 292A WS35 1,360. V48M28E77B — V48W28E11A 28,600. 51,200. 52 64 75 75 FR201 FR200 FR103 FR95 86B 86B 86B 86B IndoorOutdoor — — — — 480 ∆ Volts to 208Y/120 Volts — Copper Windings 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 172 300 370 635 765 765 511 511 511 359 359 359 78 FR909 136 FR910A 168 FR912A 283B 283B 283B WS31 WS31 WS31 350. V48M28E15CU 350. V48M28E30CU 350. V48M28E45CU 2,300. 2,520. 3,180. 75 2@+2.5% 4@-2.5% 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 550 675 850 1000 1000 1171 663 663 712 485 485 585 250 FR914B 307 FR915B 386 FR916A 283B 283B 283B WS33 WS33 WS19 350. V48M28E75CU 350. V48M28E12CU 350. V48M28E49CU 4,830. 6,600. 9,020. 225 300 500 DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1200 2150 2400 1422 1581 1905 793 794 1130 616 768 914 545 FR917 977 FR918A 1088 FR919 283B 283B 292A WS34 WS34 WS35 800. V48M28E22CU 800. V48M28E33CU 1,360. V48M28E55CU 12,150. 15,200. 24,590. 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 480 ∆ Volts to 480Y/277 Volts 9 15 2@+2.5% 2@-2.5% 2@+2.5% 2@-2.5% EPT EPT 115 115 15-7/8 17-3/8 16-1/2 19-3/4 9-7/8 10-1/2 166 275 403 441 419 419 251 266 75 FR103 75 FR95 86C 86C 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 663 359 359 485 104 FR910A 140 FR912A 217 FR914B 283B 283B 283B 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% 225 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 663 712 793 485 585 616 272 FR915B 344 FR916A 499 FR917 300 500 750 DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2400 2900 1581 1905 1905 794 1130 1130 768 914 914 728 FR918A 1088 FR919 1315 FR920 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% IndoorOutdoor — Y48D47E09N — Y48D47E15B 2,380. 3,000. WS31 WS31 WS33 350. V48M47E30B 350. V48M47E45B 350. V48M47E75B 2,560. 3,120. 4,410. 283B 283B 283B WS33 WS19 WS34 350. V48M47E12B 350. V48M47E49B 800. V48M47E22B 6,390. 8,000. 11,730. 283B 292A 292A WS34 WS35 WS35 800. V48M47E33B 1,360. V48M47E55G 1,360. V48M47E77A 14,850. 23,750. 38,600. Refer to your Cutler-Hammer sales office. Not seismic qualified. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Electrostatically Shielded Transformers 9-30 November 2003 Three-Phase, Types EPT, DT-3, 60 Hz Vol. 1, Ref. No. [0330] Table 9-30. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ FR201 FR200 FR103 FR95 88A 88A 505B 505B IndoorOutdoor Price U.S. $ 480 ∆ Volts to 240 ∆ Volts 3 6 9 15 — — — — 2@-5% 2@-5% 4@-2.5% 4@-2.5% EPT EPT EPT EPT 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 16 16-1/2 16-1/2 19-3/4 8-3/8 9-7/8 9-7/8 10-1/2 116 143 166 275 339 403 403 441 404 419 419 502 211 251 251 266 52 64 75 75 — — — — Y48G24E03A Y48G24E06A Y48J24E09A Y48J24E15A 1,310. 1,590. 2,060. 2,585. 480 ∆ Volts to 240 ∆ Volts With 120 Volt Lighting Tap on B Phase 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 230 310 635 765 765 511 511 511 359 359 359 69 FR909 104 FR910A 140 FR912A 284B 284B 284B WS31 WS31 WS31 350. V48M22E15B 350. V48M22E30A 350. V48M22E45A 1,700. 2,200. 2,750. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 712 485 485 585 217 FR914B 272 FR915B 344 FR916A 284B 284B 284B WS33 WS33 WS19 350. V48M22E75A 350. V48M22E12A 350. V48M22E49A 3,760. 5,390. 6,830. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 793 794 1130 616 768 914 499 FR917 728 FR918A 1088 FR919 284B 284B 293A WS34 WS34 WS35 800. V48M22E22A 800. V48M22E33A 1,360. V48M22E55A 10,000. 12,650. 20,150. 9 Center Tap capacity limited to 5% of rated kVA. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Energy Efficient Transformers 9-31 November 2003 Vol. 1, Ref. No. [0331] Single- and Three-Phase, Types EP, DS-3, EPT, DT-3, 60 Hz Type DT-3 Product Description Types EP, EPT ■ ■ ■ ■ ■ ■ ■ ■ Sand and Resin Encapsulated design. Suitable for indoor or outdoor applications. Totally enclosed, non-ventilated enclosures. Enclosures are NEMA 3R rated. Mountable in any position indoors and upright only outdoors. 185ºC Insulation System, 115ºC rise standard. Available in single-phase ratings through 37.5 kVA and 4160 volts primary (EP). Available in three-phase ratings through 75 kVA and 4160 volts primary (EPT). Types DS-3, DT-3 ■ ■ ■ ■ ■ ■ Ventilated, NEMA 2 enclosure standard. Suitable for indoor applications, outdoors when weathershields are also installed. Upright mounting only. 220ºC Insulation System, 150ºC rise standard. Available in single-phase ratings 15 – 167 kVA and up to 4160 volts primary (DS-3). Available in three-phase ratings 15 – 1500 kVA and up to 4160 volts primary (DT-3). Single- and Three-Phase, Types EP, DS-3, EPT, DT-3, 60 Hz Application Description Low Temperature Rise Energy Efficient transformers are designed with lower than normal conductor and total losses. Temperature rise is therefore lower resulting in greatly improved life expectancies and substantial increases in overload capabilities. 80°C and 115°C rise transformers can help cut operating expenses for systems requiring unit loading at 80 to 100% of the nameplate rating, 24 hours a day, or where load growth is expected. A 115°C rise transformer can carry a continuous 15% overload, and the 80°C rise a 30% overload, without exceeding the insulation rating or seriously reducing the life expectancy of the transformer. However, when operating in an overload condition, the internal temperature increases as a result of the higher conductor losses. Efficiency decreases under this condition. Since transformers operate beyond nameplate capacities usually during peak load periods, the benefits remain. NEMA TP-1-1996, compliant Energy Efficient Transformers are specifically designed to meet the energy efficiency standards set forth in NEMA Standards publication, TP-1-1996, “Guide for Determining Energy Efficiency for Distribution Transformers.” Surveys have shown that the average loading of low voltage dry-type distribution transformers, over a 24 hour period, is approximately 35%. NEMA TP-1 compliant transformers are optimized to offer maximum efficiency at 35% of nameplate rating. In applications where the Eaton’s Cutler-Hammer low temperature rise (115ºC or 80ºC) product offers significant energy savings. The range of products covered by NEMA TP-1-1996 are: Transformers that are currently specifically excluded from the scope of NEMA Standard TP-1-1996 include: ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Liquid-filled transformers below 10 kVA. Dry-type transformers below 15 kVA. ac and dc drives transformers. Rectifier transformers and transformers designed for high harmonics. Autotransformers. Non-distribution transformers, such as UPS transformers. Special impedance, regulation, or harmonic transformers. Regulating transformers. Sealed and non-ventilated transformers. Retrofit transformers. Machine tool transformers. Welding transformers. Transformers with tap ranges greater than 15%. Transformers with a frequency other than 60 Hz. Grounding transformers. Testing transformers. Efficiency levels set forth in NEMA TP-1-1996. Table 9-32. NEMA TP-1-1996 Efficiency Levels Tables of Energy Efficiency NEMA Class 1 Efficiency Levels dry-type Distribution Transformers — Low Voltage Single-Phase kVA Three-Phase Efficiency kVA Efficiency 97.7 98.0 98.2 15 30 45 97.0 97.5 97.7 50 75 100 98.3 98.5 98.6 75 112.5 150 98.0 98.2 98.3 167 250 333 — — 98.7 98.8 98.9 — — 15 25 37.5 225 300 500 750 1000 98.5 98.6 98.7 98.8 98.9 Table 9-31. NEMA TP-1-1996 Product Range Voltage Class Primary Voltage 34.5 kV and below Secondary Voltage 600 V and below Dry-Type Rating Single-Phase 10 – 833 kVA Three-Phase 15 – 2500 kVA Liquid Rating Single-Phase 10 – 833 kVA Three-Phase 15 – 2500 kVA Features, Benefits and Functions ■ UL listed. 60 Hz operation (except as noted). ■ Short-term overload capability as required by ANSI. ■ Meet NEMA ST-20 sound levels. ■ The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 9-32 Transformers Energy Efficient Transformers November 2003 Single- and Three-Phase, Types EP, DS-3, EPT, DT-3, 60 Hz Standards and Certifications Insulation System and Temperature Rise Winding Terminations Industry Standards Industry standards classify insulation systems and rise as shown below: Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Ventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. 9 Vol. 1, Ref. No. [0332] Options and Accessories Please refer to Page 9-120. Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hertz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one half hour; 150% load for one hour; and 125% load for four hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Table 9-33. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Cutler-Hammer ventilated transformers, Types DS-3 and DT-3, utilize a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Cutler-Hammer encapsulated transformers, Types EP and EPT, utilize a NEMA 3R rated enclosure. Sound Levels All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Series-Multiple Windings Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications Please refer Page 9-122. Table 9-34. Average Sound Levels NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers NEMA TP-1 Energy Efficient Transformers 9-33 November 2003 Single-Phase, Type DS-3 Vol. 1, Ref. No. [0333] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-35. Single-Phase Selection Information — Type DS-3 60 Hz NEMA TP-1 Compliant, kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Labeled Wt. Dimensions (mm) Wt. Frame Wiring Weathershield Style Lbs. H kg Diagram Catalog Price Number W D Number Number U.S. $ Price U.S. $ 240 x 480 Volts to 120/240 Volts, Aluminum Windings 15 25 37.5 50 75 100 167 15 25 37.5 50 75 100 15 25 37.5 50 75 100 DS-3 DS-3 DS-3 DS-3 150 150 150 150 31-1/4 31-1/4 37-5/8 42-1/8 22-5/8 22-5/8 22-5/8 24 17-1/2 17-1/2 19-1/2 23-3/8 212 768 212 768 306 956 510 1070 428 428 574 610 402 402 495 594 67 67 139 232 816 816 817 819 3XA 3XA 3XA 3XA WS11 WS11 WS11 WS16 350. 350. 350. 800. 2@+2.5% 4@-2.5% DS-3 DS-3 DS-3 150 150 150 42-1/8 62-1/2 62-1/2 24 30 30 23-3/8 34 34 510 1070 1200 1597 1200 1597 610 762 762 594 863 863 232 545 545 819 814 814 3XA 3XA 288A WS16 WS13 WS13 800. T20P11S75EE 800. T20P11S99EE 800. T48M11S67EE DS-3 DS-3 DS-3 115 115 115 31-1/4 31-1/4 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 17-1/2 19-1/2 768 768 956 428 428 574 402 402 495 67 67 154 816 816 818 3XA 3XA 3XA WS11 WS11 WS11 350. T20P11F15EE 350. T20P11F25EE 350. T20P11F37EE 2,120. 2,820. 3,380. DS-3 DS-3 DS-3 115 115 115 42-1/8 42-1/8 62-1/2 24 24 30 23-3/8 23-3/8 34 510 1070 510 1070 1200 1597 610 610 762 594 594 863 232 232 545 819 819 814 3XA 3XA 288A WS16 WS16 WS13 800. T20P11F50EE 800. T20P11F75EE 800. T20P11F99EE 4,100. 5,790. 7,080. DS-3 DS-3 DS-3 80 80 80 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 768 956 956 428 574 574 402 495 495 67 139 154 816 817 818 3XA 3XA 3XA WS11 WS11 WS11 350. T20P11B15EE 350. T20P11B25EE 350. T20P11B37EE 2,540. 3,400. 4,010. DS-3 DS-3 DS-3 80 80 80 42-1/8 42-1/8 62-1/2 24 24 30 23-3/8 23-3/8 34 510 1070 600 1070 1200 1597 610 610 762 594 594 863 232 272 545 819 820 814 3XA 3XA 288A WS16 WS16 WS13 800. T20P11B50EE 800. T20P11B75EE 800. T20P11B99EE 4,900. 6,900. 9,220. 768 956 956 956 428 574 574 574 402 495 495 495 108 158 158 173 816 817 817 818 3XA 3XA 3XA 3XA WS11 WS11 WS11 WS11 350. 350. 350. 350. 2,450. 3,280. 3,890. 4,750. 614 1070 1440 1597 1440 1597 610 762 762 594 863 863 279 655 655 819 814 814 3XA 288A 288A WS16 WS13 WS13 6,660. 800. T20P11S75CUEE 8,220. 800. T20P11S99CUEE 800. T48M11S67CUEE 16,625. 768 956 956 428 574 574 402 495 495 108 158 173 816 817 818 3XA 3XA 3XA WS11 WS11 WS11 350. T20P11F15CUEE 350. T20P11F25CUEE 350. T20P11F37CUEE 2,810. 3,760. 4,440. 614 1070 614 1070 1440 1597 610 610 762 594 594 863 279 279 655 819 819 814 3XA 3XA 288A WS16 WS16 WS13 800. T20P11F50CUEE 800. T20P11F75CUEE 800. T20P11F99CUEE 5,430. 7,620. 9,350. 768 956 956 428 574 574 402 495 495 108 158 173 816 817 818 3XA 3XA 3XA WS11 WS11 WS11 350. T20P11B15CUEE 350. T20P11B25CUEE 350. T20P11B37CUEE 3,260. 4,360. 5,150. 212 212 340 212 306 340 T20P11S15EE T20P11S25EE T20P11S37EE T20P11S50EE 1,810. 2,420. 2,860. 3,500. 4,910. 6,020. 13,300. 240 x 480 Volts to 120/240 Volts, Copper Windings 15 25 37.5 50 75 100 167 15 25 37.5 50 75 100 15 25 37.5 50 75 100 DS-3 DS-3 DS-3 DS-3 150 150 150 150 31-1/4 37-5/8 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 19-1/2 2@+2.5% 4@-2.5% DS-3 DS-3 DS-3 150 150 150 42-1/8 62-1/2 62-1/2 24 30 30 23-3/8 34 34 DS-3 DS-3 DS-3 115 115 115 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 DS-3 DS-3 DS-3 115 115 115 42-1/8 42-1/8 62-1/2 24 24 30 23-3/8 23-3/8 34 DS-3 DS-3 DS-3 80 80 80 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 DS-3 DS-3 DS-3 80 80 80 42-1/8 42-1/8 62-1/2 24 24 30 23-3/8 23-3/8 34 614 1070 700 1070 1440 1597 610 610 762 594 594 863 279 318 655 819 820 814 3XA 3XA 288A WS16 WS16 WS13 6,300. 800. T20P11B50CUEE 8,850. 800. T20P11B75CUEE 800. T48M11B99CUEE 11,610. 2@+2.5% 4@-2.5% 237 345 345 381 237 345 381 237 345 381 T20P11S15CUEE T20P11S25CUEE T20P11S37CUEE T20P11S50CUEE 208 Volts to 120/240 Volts, Aluminum Windings 15 25 37.5 50 75 100 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DS-3 DS-3 DS-3 DS-3 150 150 150 150 31-1/4 31-1/4 37-5/8 42-1/8 22-5/8 22-5/8 22-5/8 24 17-1/2 17-1/2 19-1/2 23-3/8 212 768 212 768 306 956 510 1070 428 428 574 610 402 402 495 594 67 67 139 232 816 816 817 819 260A 260A 260A 260A WS11 WS11 WS11 WS16 350. 350. 350. 800. T29M11S15EE T29M11S25EE T29M11S37EE T29M11S50EE 3,015. 5,275. 6,460. 7,840. 1@+5% 2@-5% 2@+2.5% 4@-2.5% DS-3 DS-3 150 150 42-1/8 62-1/2 24 30 23-3/8 34 510 1070 1200 1597 610 762 594 863 232 545 819 814 551A 260A WS16 WS13 800. T29R11S75EE 800. T29M11S99EE 11,085. 13,770. 277 Volts to 120/240 Volts, Aluminum Windings 15 25 37.5 50 75 100 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DS-3 DS-3 DS-3 DS-3 150 150 150 150 31-1/4 31-1/4 37-5/8 42-1/8 22-5/8 22-5/8 22-5/8 24 17-1/2 17-1/2 19-1/2 23-3/8 212 768 212 768 306 956 510 1070 428 428 574 610 402 402 495 594 67 67 139 232 816 816 817 819 262C 262C 262C 262C WS11 WS11 WS11 WS16 350. 350. 350. 800. T27M11S15EE T27M11S25EE T27M11S37EE T27M11S50EE 3,015. 5,275. 6,460. 7,840. 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DS-3 DS-3 150 150 42-1/8 62-1/2 24 30 23-3/8 34 510 1070 1200 1597 610 762 594 863 232 545 819 814 262C 262C WS16 WS13 800. T27M11S75EE 800. T27M11S99EE 11,085. 13,770. +1 – 5%, -2 – 5% at 240 volts primary; +2 – 2.5%, -4 – 2.5% at 480 volts primary. 480 volt primary only. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers NEMA TP-1 Energy Efficient Transformers 9-34 November 2003 Three-Phase, Type DT-3 Vol. 1, Ref. No. [0334] Table 9-36. Three-Phase Selection Information — Type DT-3 60 Hz NEMA TP-1 Compliant, kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Labeled Wt. Dimensions (mm) Wt. Frame Wiring Weathershield Style Lbs. H kg Diagram Catalog Price Number W D Number Number U.S. $ Price U.S. $ 480 Volts to 208Y/120 Volts, Aluminum Windings 9 15 30 45 1@+2.5% 3@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30 30 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 310 310 635 762 762 511 511 511 359 359 359 69 909 140 912A 140 912A 375A 280B 280B WS31 WS31 WS31 350. V48U28T15EE 350. V48M28T30EE 350. V48M28T45EE 1,830. 2,330. 2,840. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-1/4 39-1/4 46-5/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 995 600 995 785 1183 663 663 710 486 486 584 217 914B 272 915B 357 916A 280B 280B 280B WS33 WS33 WS19 350. V48M28T75EE 350. V48M28T12EE 350. V48M28T49EE 4,025. 5,850. 7,300. 225 300 500 750 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 56-1/4 62-1/4 75 75 31-1/4 31-1/4 44-1/2 44-1/2 24-1/4 30-1/4 35-3/4 35-3/4 1100 1444 2400 2900 1427 1579 1905 1905 793 793 1129 1129 616 768 908 908 917 918A 919 920 280B 280B 275A 275A WS34 WS34 WS35 WS35 15 30 45 1@+2.5% 3@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 25 30 39-1/4 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 152 310 480 635 762 995 511 511 663 359 359 486 69 909 140 912A 217 914B 375A 280B 280B 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 39-1/4 39-1/4 46-5/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 600 995 600 995 785 1183 663 663 710 486 486 584 272 915B 272 915B 357 916A 225 300 500 750 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 115 115 115 115 56-1/4 75 75 75 31-1/4 44-1/2 44-1/2 44-1/2 24-1/4 35-3/4 35-3/4 35-3/4 1100 2400 2900 2900 1427 1905 1905 1905 793 1129 1129 1129 616 908 908 908 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 30 30 39-1/4 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 762 762 995 511 511 663 359 359 486 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 39-1/4 46-5/8 56-1/4 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 995 785 1183 1100 1427 663 710 793 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 35-3/4 35-3/4 1444 1579 2400 1905 2900 1905 793 1129 1129 499 656 1088 1315 800. 800. 1,360. 1,360. V48M28T22EE V48M28T33EE V48M28T55EE V48M28T77EE 10,680. 13,500. 21,800. 36,800. WS31 WS31 WS33 350. V48U28F15EE 350. V48M28F30EE 350. V48M28F45EE 2,380. 2,840. 3,475. 280B 280B 280B WS33 WS33 WS19 350. V48M28F75EE 350. V48M28F12EE 350. V48M28F49EE 5,290. 7,215. 9,850. 280B 275A 275A 275A WS34 WS34 WS35 WS35 104 910A 140 912A 217 914B 280B 280B 280B 486 584 616 272 915B 357 916A 499 917 768 908 908 656 918A 1088 919 1315 920 499 1088 1315 1315 917 919 920 920 800. 800. 1,360. 1,360. V48M28F22EE V48M28F33EE V48M28F55EE V48M28F77EE 13,150. 16,490. 25,070. 40,365. WS31 WS31 WS33 350. V48M28B15EE 350. V48M28B30EE 350. V48M28B45EE 2,800. 3,250. 4,085. 280B 280B 280B WS33 WS19 WS34 350. V48M28B75EE 350. V48M28B12EE 800. V48M28B49EE 6,190. 8,450. 11,550. 280B 275A 275A WS34 WS35 WS35 800. V48M28B22EE 1,360. V48M28B33EE 1,360. V48M28B55EE 15,450. 19,350. 29,430. 480 Volts to 240 Volts with 120 Volt Lighting Tap Phase B, Aluminum Windings 15 30 45 1@+2.5% 3@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30 39-1/4 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 152 310 480 635 762 995 511 511 663 359 359 486 69 909 140 912A 217 914B 282B 282B WS31 WS31 WS33 350. V48U22T15EE 350. V48M22T30EE 350. V48M22T45EE 2,095. 2,800. 3,500. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-1/4 39-1/4 46-5/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 600 995 600 995 785 1183 663 663 710 486 486 584 272 915B 272 915B 357 916A 282B 282B 282B WS33 WS33 WS19 350. V48M22T75EE 350. V48M22T12EE 350. V48M22T49EE 4,830. 7,020. 8,760. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56-1/4 75 75 31-1/4 44-1/2 44-1/2 24-1/4 35-3/4 35-3/4 1100 1427 2400 1905 2900 1905 793 1129 1129 616 908 908 282B 282B 291A WS34 WS35 WS35 800. V48M22T22EE 1,360. V48M22T33EE 1,360. V48M22T55EE 12,850. 16,300. 26,500. 499 917 1088 919 1315 920 Refer to your local Cutler-Hammer sales office. Note: Additional voltage combinations are available. Contact your local Cutler-Hammer sales office for assistance if the voltage you require is not included in this catalog. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers NEMA TP-1 Energy Efficient Transformers 9-35 November 2003 Three-Phase, Type DT-3 Vol. 1, Ref. No. [0335] Table 9-36. (Continued) Three-Phase Selection Information — Type DT-3 60 Hz NEMA TP-1 Compliant, kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Labeled Wt. Dimensions (mm) Wt. Frame Wiring Weathershield Style Lbs. H kg Diagram Catalog Price Number W D Number Number U.S. $ Price U.S. $ 480 Volts to 208Y/120 Volts, Copper Windings 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30 30 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 172 370 370 635 762 762 511 511 511 359 359 359 78 909 168 912A 168 912A 280B 280B 280B WS31 WS31 WS31 350. V48M28T15CUEE 350. V48M28T30CUEE 350. V48M28T45CUEE 2,800. 3,170. 3,870. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-1/4 39-1/4 46-5/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 675 995 675 995 870 1183 663 663 710 486 486 584 307 915B 307 915B 391 916A 280B 280B 280B WS33 WS33 WS19 350. V48M28T75CUEE 350. V48M28T12CUEE 350. V48M28T49CUEE 5,470. 7,960. 9,940. 225 300 500 750 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 56-1/4 62-1/4 75 75 31-1/4 31-1/4 44-1/2 44-1/2 24-1/4 30-1/4 35-3/4 35-3/4 1200 1894 3100 3600 1427 1579 1905 1905 793 793 1129 1129 616 768 908 908 917 918A 919 920 280B 280B 275A 275A WS34 WS34 WS35 WS35 15 30 45 2@+2.5% 2@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 25 30 39-1/4 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 172 370 550 635 762 995 511 511 663 359 359 486 78 909 168 912A 250 914B 266W 280B 280B 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 39-1/4 39-1/4 46-5/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 675 995 675 995 870 1183 663 663 710 486 486 584 307 915B 307 915B 391 916A 225 300 500 750 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 115 115 115 115 56-1/4 75 75 75 31-1/4 44-1/2 44-1/2 44-1/2 24-1/4 35-3/4 35-3/4 35-3/4 1200 3100 3100 3600 1427 1905 1905 1905 793 1129 1129 1129 616 908 908 908 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 30 30 39-1/4 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 300 370 675 762 762 995 511 511 663 359 359 486 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 39-1/4 46-5/8 56-1/4 26-1/8 28 31-1/4 19-1/8 23 24-1/4 675 995 870 1183 1200 1427 663 710 793 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 35-3/4 35-3/4 1894 1579 3100 1905 3600 1905 545 861 1409 1636 800. 800. 1,360. 1,360. V48M28T22CUEE V48M28T33CUEE V48M28T55CUEE V48M28T77CUEE 15,500. 18,500. 29,800. 47,390. WS31 WS31 WS33 350. V48D28F15CUEE 350. V48M28F30CUEE 350. V48M28F45CUEE 3,210. 3,825. 4,690. 280B 280B 280B WS33 WS33 WS19 350. V48M28F75CUEE 350. V48M28F12CUEE 350. V48M28F49CUEE 7,140. 9,740. 13,300. 280B 275A 275A 275A WS34 WS35 WS35 WS35 136 910A 168 912A 307 915B 280B 280B 280B 486 584 616 307 915B 391 916A 545 917 793 1129 1129 768 908 908 861 918A 1409 919 1636 920 545 1409 1409 1636 917 919 919 920 800. 1,360. 1,360. 1,360. V48M28F22CUEE V48M28F33CUEE V48M28F55CUEE V48M28F77CUEE 17,750. 22,250. 33,790. 52,000. WS31 WS31 WS33 350. V48M28B15CUEE 350. V48M28B30CUEE 350. V48M28B45CUEE 3,780. 4,130. 5,510. 280B 280B 280B WS33 WS19 WS34 350. V48M28B75CUEE 350. V48M28B12CUEE 800. V48M28B49CUEE 8,350. 11,400. 15,600. 280B 275A 275A WS34 WS35 WS35 800. V48M28B22CUEE 1,360. V48M28B33CUEE 1,360. V48M28B55CUEE 20,860. 26,120. 37,060. 480 Volts to 240 Volts with 120 Volt Lighting Tap Phase B, Copper Windings 15 30 45 1@+2.5% 3@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30 39-1/4 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 172 370 550 635 762 995 511 511 663 359 359 486 78 909 168 912A 250 914B 282B 282B WS31 WS31 WS33 350. V48U22T15CUEE 350. V48M22T30CUEE 350. V48M22T45CUEE 2,830. 3,790. 4,730. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-1/4 39-1/4 46-5/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 675 995 675 995 870 1183 663 663 710 486 486 584 307 915B 307 915B 391 916A 282B 282B 282B WS33 WS33 WS19 350. V48M22T75CUEE 350. V48M22T12CUEE 350. V48M22T49CUEE 6,470. 9,480. 11,850. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56-1/4 75 75 31-1/4 44-1/2 44-1/2 24-1/4 35-3/4 35-3/4 1200 1427 3100 1905 3600 1905 793 1129 1129 616 908 908 282B 282B 291A WS34 WS35 WS35 800. V48M22T22CUEE 1,360. V48M22T33CUEE 1,360. V48M22T55CUEE 17,380. 21,900. 35,800. 545 917 1409 919 1636 920 Refer to your local Cutler-Hammer sales office. Note: Additional voltage combinations are available. Contact your local Cutler-Hammer sales office for assistance if the voltage you require is not included in this catalog. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Low Temperature Rise Energy Efficient Transformers 9-36 November 2003 Single-Phase, Type DS-3 Vol. 1, Ref. No. [0336] Table 9-37. Single-Phase Selection Information — Type DS-3, 60 Hz Low Temperature Rise kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 240 x 480 Volts to 120/240 Volts 15 25 37.5 50 75 100 15 25 37.5 50 75 100 DS-3 DS-3 DS-3 80 80 80 30-1/4 31-1/4 37-5/8 16-7/8 22-5/8 22-5/8 15-7/8 17-1/2 19-1/2 2@+2.5% 4@-2.5% DS-3 DS-3 DS-3 80 80 80 37-5/8 42-1/8 62-1/8 22-5/8 24 30 19-1/2 23-3/8 34 DS-3 DS-3 DS-3 115 115 115 30-1/4 31-1/4 37-5/8 16-7/8 22-5/8 22-5/8 15-7/8 17-1/2 19-1/2 147 212 306 DS-3 DS-3 DS-3 115 115 115 37-5/8 42-1/8 42-1/8 22-5/8 24 24 19-1/2 23-3/8 23-3/8 147 212 306 768 793 953 428 574 574 402 445 495 67 96 139 FR816 FR817 FR818 3XA 3XA 3XA WS11 WS11 WS11 350. T20P11B15 350. T20P11B25 350. T20P11B37 1,980. 2,560. 3,125. 340 953 510 1070 1150 1597 574 610 762 495 594 863 154 233 612 FR819 FR820 FR814 3XA 3XA 288A WS16 WS16 WS13 800. T20P11B50 800. T20P11B75 800. T48M11B99A 3,790. 5,350. 8,900. 768 793 953 428 574 574 402 445 495 67 96 139 FR815 FR816 FR817 3XA 3XA 3XA WS15 WS11 WS11 350. T20P11F15 350. T20P11F25 350. T20P11F37 1,680. 2,200. 2,660. 340 953 510 1070 600 1070 574 610 610 495 594 594 154 233 274 FR818 FR819 FR820 3XA 3XA 3XA WS11 WS16 WS16 350. T20P11F50 800. T20P11F75 800. T20P11F99 3,170. 4,520. 5,630. +1 – 5%, -2 – 5% at 240 volts primary; +2 – 2.5%, -4 – 2.5% at 480 volts primary. 480 volt primary only. 9 For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Low Temperature Rise Energy Efficient Transformers 9-37 November 2003 Three-Phase, Types EPT and DT-3 Vol. 1, Ref. No. [0337] Table 9-38. Three-Phase Selection Information — Types EPT, DT-3, 60 Hz Low Temperature Rise kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 208Y/120 Volts 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 80 80 80 80 30-1/8 30-1/8 39-3/8 39-3/8 20-1/8 20-1/8 26-1/8 26-1/8 14-1/8 14-1/8 19-1/8 19-1/8 230 310 480 600 765 765 1000 1000 511 511 663 663 359 359 486 486 104 140 217 272 FR910A FR912A FR914B FR915B 280B 280B 280B 280B WS31 WS31 WS33 WS33 350. 350. 350. 350. V48M28B15A V48M28B30R V48M28B45R V48M28B75R 1,830. 2,350. 2,860. 4,040. 112.5 150 225 300 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 80 80 80 80 46-1/8 56 62-1/4 75 28 31-1/4 31-1/4 44-1/2 23 24-1/4 30-1/4 36 820 1100 1600 2400 1171 1422 1581 1905 712 793 794 1130 585 616 768 914 371 499 728 1088 FR916A FR917 FR918A FR919 280B 280B 280B 280B WS19 WS34 WS34 WS35 350. 800. 800. 1,360. V48M28B12R V48M28B49P V48M28B22P V48M28B33R 5,850. 7,350. 10,670. 13,700. 2@+2.5% 4@-2.5% — — 1@+4.2% 1@-4.2% DT-3 — DT-3 80 — 80 75 — 44-1/2 — 35-3/4 — 3000 — 1905 — 1131 — 908 — 1365 — FR920 — 275A — WS35 — 1,360. V48M28B55R — V48D28B77 — V48T28B11R 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 115 115 115 115 25 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 14-1/8 19-1/8 152 230 310 480 635 765 765 1000 511 511 511 663 359 359 359 486 69 104 140 217 FR909 FR910A FR912A FR914B 280B 280B 280B 280B WS31 WS31 WS31 WS33 350. 350. 350. 350. V48M28F15B V48M28F30R V48M28F45R V48M28F75R 1,570. 2,000. 2,440. 3,450. 112.5 150 225 300 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 115 115 115 115 39-3/8 46-1/8 56 62-1/4 26-1/8 28 31-1/4 31-1/4 19-1/8 23 24-1/4 30-1/4 600 760 1100 1600 1000 1171 1422 1581 663 712 793 794 486 585 616 768 272 344 499 728 FR915B FR916A FR917 FR918A 280B 280B 280B 280B WS19 WS33 WS34 WS34 350. 350. 800. 800. V48M28F12R V48M28F49P V48M28F22P V48M28F33P 4,950. 6,250. 9,100. 11,750. 2@+2.5% 4@-2.5% 1@+3.5% 1@-3.5% 1@+4.2% 1@-4.2% DT-3 DT-3 DT-3 115 115 115 75 44-1/2 36 2400 1905 1130 914 1088 FR919 275A WS35 72B 500 750 1000 500 750 1000 1,360. V48M28F55P — V48W28F77T — V48T28F11R 22,000. 35,100. 65,100. 18,750. 31,200. 55,550. 480 ∆ Volts to 208Y/120 Volts, Copper Windings 9 2@+2.5% 2@-2.5% EPT 80 17-3/8 19-11/16 10-7/16 300 441 499 265 136 FR95 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 300 370 550 765 765 1000 511 511 663 359 359 486 136 168 250 FR910A FR912A FR914B 75 112.5 150 225 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 80 80 80 80 39-3/8 46-1/8 56 62-1/4 26-1/8 28 31-1/4 31-1/4 19-1/8 675 20-3/16 850 24-1/4 1200 30-1/4 2150 1000 1171 1422 1581 663 712 793 794 486 585 616 768 307 386 545 977 300 500 750 2@+2.5% 4@-2.5% 2@+3.1% 2@-3.1% 1@+3.5% 1@-3.5% DT-3 DT-3 DT-3 80 80 80 75 44-1/2 36 3100 1905 1130 914 1409 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 DT-3 115 115 115 115 25 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 14-1/8 19-1/8 172 300 370 550 635 765 765 1000 511 511 511 663 359 359 359 486 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% 225 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 675 850 1200 1000 1171 1422 663 712 793 300 500 750 DT-3 DT-3 DT-3 115 115 115 62-1/4 75 31-1/4 44-1/2 30-1/4 36 2150 3100 1581 1905 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 310 480 600 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% 225 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 46-1/8 56 62-1/4 28 31-1/4 31-1/4 23 24-1/4 30-1/4 300 500 2@+2.5% 4@-2.5% 2@+3.1% 2@-3.1% DT-3 DT-3 80 80 75 44-1/2 36 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% 225 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 39-3/8 46-1/8 56 300 500 750 DT-3 DT-3 DT-3 115 115 115 62-1/4 75 15 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 1@+3.5% 1@-3.5% 280B 280B 280B IndoorOutdoor WS31 WS31 WS33 — — 350. 350. 350. Y48D28B09CU — V48M28B15CU V48M28B30CU V48M28B45CU 3,000. — 2,700. 3,100. 3,940. FR915B FR916A FR917 FR918A 280B 280B 280B 280B WS33 WS19 WS34 WS34 350. 350. 800. 800. V48M28B75CU V48M28B12CU V48M28B49CU V48M28B22CU 5,970. 8,160. 11,150. 14,900. FR919 280B WS35 1,360. V48M28B33CU — V48M28B55CU — V48W28B77CU 18,660. 33,700. 44,500. 78 136 168 250 FR909 FR910A FR912A FR914B 280B 280B 280B 280B WS31 WS31 WS31 WS33 350. 350. 350. 350. V48M28F15CU V48M28F30CU V48M28F45CU V48M28F75CU 2,300. 2,740. 3,350. 5,100. 486 585 616 307 386 545 FR915B FR916A FR917 280B 280B 280B WS19 WS33 WS34 350. V48M28F12CU 350. V48M28F49CU 800. V48M28F22CU 6,960. 9,510. 12,690. 794 1130 768 914 977 1409 FR918A FR919 280B 275A WS34 WS35 800. V48M28F33CU 1,360. V48M28F55CU — V48W28F77CU 16,000. 25,950. 39,500. 765 1000 1000 511 663 663 359 486 486 140 217 272 FR912A FR914B FR915B 281B 281B 281B WS31 WS33 WS33 350. V48M24B30R 350. V48M24B45P 350. V48M24B75P 2,700. 3,400. 4,630. 760 1100 1600 1171 1422 1581 712 793 794 585 616 768 344 499 728 FR916A FR917 FR918A 281B 281B 281B WS19 WS34 WS34 350. V48M24B12P 800. V48M24B49P 800. V48M24B22P 6,660. 9,250. 12,300. 2400 1905 1130 914 1088 FR919 281B WS35 1,360. V48M24B33P — V48X24B55N 15,525. 26,400. 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 663 359 359 486 104 140 217 FR910A FR912A FR914B 281B 281B 281B WS31 WS31 WS33 350. V48M24F30P 350. V48M24F45P 350. V48M24F75P 2,300. 2,900. 3,950. 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 663 712 793 486 585 616 272 344 499 FR915B FR916A FR917 281B 281B 281B WS19 WS33 WS34 350. V48M24F12P 350. V48M24F49P 800. V48M24F22P 5,640. 7,140. 10,470. 31-1/4 44-1/2 30-1/4 36 1600 2400 1581 1905 794 1130 768 914 728 1088 FR918A FR919 281B 274B WS34 WS35 800. V48M24F33P 1,360. V48M24F55N — V48W24F77N 13,225. 21,050. 37,450. 480 ∆ Volts to 240 ∆ Volts 30 45 75 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 1@+3.5% 1@-3.5% Refer to your Cutler-Hammer sales office. No UL label. Contact your local Cutler-Hammer sales office if UL label is required. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Energy Efficient Harmonic Mitigating Transformers 9-38 November 2003 Three-Phase, Type DT-3 HMT, 60 Hz Energy Efficient Harmonic Mitigating Transformers Product Description Three-Phase, Type DT-3 HMT, 60 Hz ■ ■ 9 ■ ■ ■ ■ Harmonic mitigating (cancellation) transformers are a cost-effective means of treating harmful harmonics in an electrical distribution system. Reducing harmonic content in electrical systems can result in a more reliable electrical system, lower maintenance costs, less downtime, fewer equipment malfunctions, and lower cooling system capacity. Available in a variety of phase-shift configurations that allow flexibility to target specific harmonics. Harmonic treatment via electromagnetic flux cancellation. May be installed as a stand-alone transformer, or included in IFS Available in three-phase ratings 15 – 300 kVA, up to 600 volts primary. Application Description Eaton’s Cutler-Hammer harmonic mitigating transformers are available in three phase-shift configurations. Type NON is 0° phase-shift; Type NEG is 15°; and Type POS is +15° phase-shift. The harmonic profile of a specific load will determine which of these transformers, or combination of transformers, is best suited for a particular application. As with any method of treating harmonics, the load profile needs to be known. Type NON harmonic mitigating transformers are ideally suited for applications where the nonlinear loads are single-phase. Such devices as computers, lighting ballasts, office equipment, diagnostic equipment, cash registers, and other electronic equipment are all common single-phase loads that generate harmonic currents. Single-phase loads, such as those previously mentioned, generate harmonic profiles that are rich in 3rd and other triplen (9th, 15th, 21st, …) harmonic currents. Type NON harmonic mitigating transformers treat triplen harmonics in the secondary windings such that these harmonics are not coupled into the primary delta. Vol. 1, Ref. No. [0338] In addition to treating triplen harmonics, Types POS and NEG harmonic mitigating transformers may be used in pairs to treat 5th, 7th, and higher order harmonics commonly generated by three-phase loads. As with Type NON transformers, POS and NEG treat triplen harmonics in the secondary of each transformer. 5th, 7th and other higher order harmonics pass through the transformers and are canceled in the common bus that feeds the pair of transformers. It is not necessary for the POS and NEG transformers to be located in the same room to achieve harmonic treatment. In order to attain maximum harmonic treatment, every effort should be made to balance the nonlinear loads phase-to-phase as well as between multiple transformers. Features and Benefits ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 480 volt delta to 208Y/120 volt standard. Additional voltage combinations available. 150°C, 115°C, or 80°C temperature rise available. Copper windings and terminals standard. NEMA TP-1 energy efficient and labeled. 200% rated neutral. Single electrostatic shield for attenuation of common mode and transverse mode noise. Approximately 98% efficient when operated in systems with 100% nonlinear load profiles. Low zero sequence impedance and zero sequence reactance. 220°C insulation system. Third party tested for harmonic performance and energy efficiency. Meets NEMA ST-20 sound standards. For more information visit: www.cutler-hammer.eaton.com Standards and Certifications Industry Standards All Cutler-Hammer dry-type transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. Harmonic Mitigating Transformers are UL listed. Seismic Qualified Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed the requirements of the Uniform Building Code (UBC) and California Code Title 24. Options and Accessories Harmonic mitigating transformers are available with the same options and accessories as general purpose ventilated transformers. Please refer to Page 9-120. CA08101001E Transformers Energy Efficient Harmonic Mitigating Transformers 9-39 November 2003 Three-Phase, Type DT-3 HMT, 60 Hz Vol. 1, Ref. No. [0339] Product Specifications Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Industry standards classify insulation systems and rise as shown below: Cutler-Hammer ventilated transformers, Types DS-3 and DT-3 utilize a NEMA 2 rated (drip-proof) enclosure as a standard, and are rated NEMA 3R with the addition of weathershields. Cutler-Hammer encapsulated transformers, Types EP and EPT, utilize a NEMA 3R rated enclosure as standard. Table 9-39. Insulation System Classification Sound Levels Insulation System and Temperature Rise Overload Capacity Short-term overload is designed into transformers as required by ANSI. Drytype distribution transformers will deliver 200% nameplate load for onehalf hour; 150% load for one hour; and 125% load for four hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Enclosures Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 levels listed here. Lower sound levels are available and must be designed specially. The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Table 9-40. Average Sound Levels 9 NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Table 9-41. Type NON Harmonic Mitigating Transformer Selection Information kVA Full Cap. Taps FCAN Type FCBN °C Temp. Rise Dimensions (Inches) H W D Wt. Lbs. Dimensions (mm) H W D Wt. kg Frame Wiring Diagram Number Weathershield Catalog Number Price U.S. $ Style Number Price U.S. $ 480 ∆ Volts to 208Y/120 Volts, Shielded, Copper Windings, NEMA TP-1 Energy Efficient, 0-Degree Phase-shift 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30 30 39-1/4 20-1/4 20-1/4 26-1/4 14-1/4 14-1/4 19-1/4 75 2@+2.5% 4@-2.5% 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 46-5/8 56-1/4 62-1/4 28 31-1/4 31-1/4 225 300 2@+2.5% 4@-2.5% 2@+2.5% 2@-2.5% DT-3 DT-3 150 150 75 75 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 75 2@+2.5% 4@-2.5% 112.5 2@+2.5% 4@-2.5% 150 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 225 300 DT-3 DT-3 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 320 420 650 762 762 997 514 514 667 362 362 489 145 191 295 910A 912A 914B 200X 200X 200X WS31 WS31 WS33 350. X48M28T15CUEENON 350. X48M28T30CUEENON 350. X48M28T45CUEENON 6,070. 7,430. 9,100. 23 24-1/4 30-1/4 850 1184 2000 1429 2170 1581 711 794 794 584 616 768 386 909 986 916A 917 918A 200X 200X 200X WS19 WS34 WS34 350. X48M28T75CUEENON 800. X48M28T12CUEENON 800. X48M28T49CUEENON 11,710. 15,450. 21,400. 44-1/2 44-1/2 35-3/4 35-3/4 3100 1905 3300 1905 1130 1130 908 908 1409 1500 919 919 201X 201X WS35 WS35 1,360. X48M28T22CUEENON 1,360. X48M28T33CUEENON 26,250. 36,300. 30 30 39-1/4 20-1/4 20-1/4 26-1/4 14-1/4 14-1/4 19-1/4 762 762 997 514 514 667 362 362 489 145 191 295 910A 912A 914B 200X 200X 200X WS31 WS31 WS33 350. X48M28F15CUEENON 350. X48M28F30CUEENON 350. X48M28F45CUEENON 6,620. 8,110. 9,930. 115 115 115 46-5/8 56-1/4 62-1/4 28 31-1/4 31-1/4 23 24-1/4 30-1/4 850 1184 2000 1429 2170 1581 711 794 794 584 616 768 386 909 986 916A 917 918A 200X 200X 200X WS19 WS34 WS34 350. X48M28F75CUEENON 800. X48M28F12CUEENON 800. X48M28F49CUEENON 12,770. 16,850. 23,330. 115 115 75 75 44-1/2 44-1/2 35-3/4 35-3/4 3100 1905 3300 1905 1130 1130 908 908 1409 1500 919 919 201X 201X WS35 WS35 1,360. X48M28F22CUEENON 1,360. X48M28F33CUEENON 28,700. 39,500. 320 420 650 For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 Transformers Energy Efficient Harmonic Mitigating Transformers 9-40 November 2003 Three-Phase, Type DT-3 HMT, 60 Hz Vol. 1, Ref. No. [0340] Table 9-42. Type POS Harmonic Mitigating Transformer Selection Information kVA Full Cap. Taps FCAN Type FCBN °C Temp. Rise Dimensions (Inches) H W D Wt. Lbs. Dimensions (mm) H W D Wt. kg Frame Wiring Diagram Number Weathershield Catalog Number Price U.S. $ Style Number Price U.S. $ 480 ∆ Volts to 208Y/120 Volts. No Thermal Sensor, Shielded, Copper Windings, NEMA TP-1 Energy Efficient, +15-Degree Phase-shift 9 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30 30 39-1/4 20-1/4 20-1/4 26-1/4 14-1/4 14-1/4 19-1/4 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 46-5/8 56-1/4 62-1/4 28 31-1/4 31-1/4 225 300 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 150 150 75 75 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 225 300 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 320 420 650 762 762 997 514 514 667 362 362 489 145 191 295 910A 912A 914B 200X 200X 200X WS31 WS31 WS33 350. X48M28T15CUEEPOS 350. X48M28T30CUEEPOS 350. X48M28T45CUEEPOS 8,060. 9,085. 12,030. 23 24-1/4 30-1/4 850 1184 2000 1429 2170 1581 711 794 794 584 616 768 386 909 986 916A 917 918A 200X 200X 200X WS19 WS34 WS34 350. X48M28T75CUEEPOS 800. X48M28T12CUEEPOS 800. X48M28T49CUEEPOS 14,890. 20,160. 28,500. 44-1/2 44-1/2 35-3/4 35-3/4 3100 1905 3300 1905 1130 1130 908 908 1409 1500 919 919 201X 201X WS35 WS35 1,360. X48M28T22CUEEPOS 1,360. X48M28T33CUEEPOS 33,300. 37,900. 30 30 39-1/4 20-1/4 20-1/4 26-1/4 14-1/4 14-1/4 19-1/4 762 762 997 514 514 667 362 362 489 145 191 295 910A 912A 914B 200X 200X 200X WS31 WS31 WS33 350. X48M28F15CUEEPOS 350. X48M28F30CUEEPOS 350. X48M28F45CUEEPOS 8,770. 9,900. 13,100. 115 115 115 46-5/8 56-1/4 62-1/4 28 31-1/4 31-1/4 23 24-1/4 30-1/4 850 1184 2000 1429 2170 1581 711 794 794 584 616 768 386 909 986 916A 917 918A 200X 200X 200X WS19 WS34 WS34 350. X48M28F75CUEEPOS 800. X48M28F12CUEEPOS 800. X48M28F49CUEEPOS 16,200. 21,900. 31,000. 115 115 75 75 44-1/2 44-1/2 35-3/4 35-3/4 3100 1905 3300 1905 1130 1130 908 908 1409 1500 919 919 201X 201X WS35 WS35 1,360. X48M28F22CUEEPOS 1,360. X48M28F33CUEEPOS 34,900. 39,900. 320 420 650 480 ∆ Volts to 208Y/120 Volts. Single Thermal Sensor Included, Shielded, Copper Windings, NEMA TP-1 Energy Efficient, +15-Degree Phase-shift 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 30 30 39-1/4 20-1/4 20-1/4 26-1/4 14-1/4 14-1/4 19-1/4 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 46-5/8 56-1/4 62-1/4 28 31-1/4 31-1/4 225 300 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 115 115 75 75 44-1/2 44-1/2 320 420 650 762 762 997 514 514 667 362 362 489 145 191 295 910A 912A 914B 200X 200X 200X WS31 WS31 WS33 350. X48M28F15TCUEEPOS 350. X48M28F30TCUEEPOS 350. X48M28F45TCUEEPOS 8,790. 9,920. 13,120. 23 24-1/4 30-1/4 850 1184 2000 1429 2170 1581 711 794 794 584 616 768 386 909 986 916A 917 918A 200X 200X 200X WS19 WS34 WS34 350. X48M28F75TCUEEPOS 800. X48M28F12TCUEEPOS 800. X48M28F49TCUEEPOS 16,250. 22,000. 31,100. 35-3/4 35-3/4 3100 1905 3300 1905 1130 1130 908 908 1409 1500 919 919 201X 201X WS35 WS35 1,360. X48M28F22TCUEEPOS 1,360. X48M28F33TCUEEPOS 35,000. 43,000. Wt. kg Frame Wiring Diagram Number Weathershield Table 9-43. Type NEG Harmonic Mitigating Transformer Selection Information kVA Full Cap. Taps FCAN Type FCBN °C Temp. Rise Dimensions (Inches) H W D Wt. Lbs. Dimensions (mm) H W D Catalog Number Price U.S. $ Style Number Price U.S. $ 480 ∆ Volts to 208Y/120 Volts. No Thermal Sensor, Shielded, Copper Windings, NEMA TP-1 Energy Efficient, -15-Degree Phase-shift 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30 30 39-1/4 20-1/4 20-1/4 26-1/4 14-1/4 14-1/4 19-1/4 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 46-5/8 56-1/4 62-1/4 28 31-1/4 31-1/4 225 300 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 150 150 75 75 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 225 300 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 320 420 650 762 762 997 514 514 667 362 362 489 145 191 295 910A 912A 914B 200X 200X 200X WS31 WS31 WS33 350. X48M28T15CUEENEG 350. X48M28T30CUEENEG 350. X48M28T45CUEENEG 8,060. 9,085. 12,030. 23 24-1/4 30-1/4 850 1184 2000 1429 2170 1581 711 794 794 584 616 768 386 909 986 916A 917 918A 200X 200X 200X WS19 WS34 WS34 350. X48M28T75CUEENEG 800. X48M28T12CUEENEG 800. X48M28T49CUEENEG 14,890. 20,160. 28,500. 44-1/2 44-1/2 35-3/4 35-3/4 3100 1905 3300 1905 1130 1130 908 908 1409 1500 919 919 201X 201X WS35 WS35 1,360. X48M28T22CUEENEG 1,360. X48M28T33CUEENEG 33,300. 37,900. 30 30 39-1/4 20-1/4 20-1/4 26-1/4 14-1/4 14-1/4 19-1/4 762 762 997 514 514 667 362 362 489 145 191 295 910A 912A 914B 200X 200X 200X WS31 WS31 WS33 350. X48M28F15CUEENEG 350. X48M28F30CUEENEG 350. X48M28F45CUEENEG 8,770. 9,900. 13,100. 115 115 115 46-5/8 56-1/4 62-1/4 28 31-1/4 31-1/4 23 24-1/4 30-1/4 850 1184 2000 1429 2170 1581 711 794 794 584 616 768 386 909 986 916A 917 918A 200X 200X 200X WS19 WS34 WS34 350. X48M28F75CUEENEG 800. X48M28F12CUEENEG 800. X48M28F49CUEENEG 16,200. 21,900. 31,000. 115 115 75 75 44-1/2 44-1/2 35-3/4 35-3/4 3100 1905 3300 1905 1130 1130 908 908 1409 1500 919 919 201X 201X WS35 WS35 1,360. X48M28F22CUEENEG 1,360. X48M28F33CUEENEG 34,900. 39,900. 320 420 650 480 ∆ Volts to 208Y/120 Volts. Single Thermal Sensor Included, Shielded, Copper windings, NEMA TP-1 Energy Efficient, -15-Degree Phase-shift 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 30 30 39-1/4 20-1/4 20-1/4 26-1/4 14-1/4 14-1/4 19-1/4 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 46-5/8 56-1/4 62-1/4 28 31-1/4 31-1/4 225 300 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% DT-3 DT-3 115 115 75 75 44-1/2 44-1/2 320 420 650 762 762 997 514 514 667 362 362 489 145 191 295 910A 912A 914B 200X 200X 200X WS31 WS31 WS33 350. X48M28F15TCUEENEG 350. X48M28F30TCUEENEG 350. X48M28F45TCUEENEG 8,790. 9,920. 13,120. 23 24-1/4 30-1/4 850 1184 2000 1429 2170 1581 711 794 794 584 616 768 386 909 986 916A 917 918A 200X 200X 200X WS19 WS34 WS34 350. X48M28F75TCUEENEG 800. X48M28F12TCUEENEG 800. X48M28F49TCUEENEG 16,250. 22,000. 31,100. 35-3/4 35-3/4 3100 1905 3300 1905 1130 1130 908 908 1409 1500 919 919 201X 201X WS35 WS35 1,360. X48M28F22TCUEENEG 1,360. X48M28F33TCUEENEG 35,000. 43,000. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers K Factor Transformers 9-41 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0341] K Factor Transformers Single- and Three-Phase, Type KT, 60 Hz, for Nonlinear Loads Coils Windings are continuous wound aluminum or optional copper construction sized and configured to reduce overheating caused by harmonic currents. These coils reduce skin and proximity effect losses which occur when current carrying conductors next to each other and coiled around steel generate magnetic fields. These magnetic fields push the currents in the conductors away from each other causing increased losses and additional heating. Neutral Bus Type KT Product Description ■ Suitable for indoor or outdoor applications (with weathershield). ■ Ventilated enclosures. ■ 220°C Insulation system, 150°C Rise standard (self extinguishing). Application Description Cutler-Hammer KT Transformers by Eaton Corporation include several major design improvements that address the problems caused by nonlinear loads and harmonics. They are designed to withstand the effects of harmonic currents without exceeding the temperature rating of the insulation system. The KT design compensates for the stresses on a transformer’s winding insulation which prevents insulation breakdown and premature failure. The net result is longer transformer life. The neutral bus is sized and configured to accommodate at least 200% of the rated current. This compensates for the increased neutral currents found in non-linear loads thus reducing heat. The K Factor A common industry term for the amount of harmonics produced by a given load is the K Factor. The larger the K Factor, the more harmonics are present. Linear loads, for example have a K Factor of 1. Transformers may carry a K Factor rating to define the transformer’s ability to withstand the additional heating generated by harmonic currents. Calculating the K Factor All nonlinear waveforms can be broken down mathematically into a fundamental frequency and its harmonics. IEEE C57.110 establishes a direct relationship between these harmonics and transformer heating. Underwriters Laboratories has established a similar relation-ship, the K Factor, which is derived by summing the square of the percentage current at a given harmonic level multiplied by the square of the harmonic order. K = ∑(Ih)2(h)2 Ih = Percent Current at Harmonic h h = Harmonic Order, i.e., 3rd, 5th, 7th For example, a load that is 90% of the fundamental, 30% of the third harmonic, and 20% of the fifth harmonic would yield (.9)2(1)2 + (.3)2(3)2 + (.2)2(5)2 or a K Factor of 2.62. This load would require a Cutler-Hammer KT-4 Transformer with a K Factor rating of 4. Transformers that carry a K Factor rating define the transformer’s ability to withstand a given harmonic load while operating within the transformer’s insulation class. An analysis of harmonic loads and a calculation of the K Factor must be made to properly apply transformers in any building or facility. Note that the calculated K Factor is not constant since non-linear loads change throughout the day as equipment and lighting is turned off and on. These harmonic loads also change over the life of the building or facility as equipment is added or removed. Harmonic Currents Harmonic currents are found in nonlinear loads. These currents are generated by various types of equipment including switching mode power supplies that abruptly switch current on and off during each line cycle. Switching mode power supplies or diodecapacitor Design Features Core A high grade, nonaging, silicon steel with high magnetic permeability provides reduced core induction levels, preventing saturation as a result of the higher frequency harmonics and resultant peak voltages. In a core approaching saturation, the current in the coil will increase as voltage drops because the core cannot absorb the additional magnetic flux. This core also provides reduced eddy currents or induced currents in the steel caused by the high ratios of peak-to-rms currents and voltages found in harmonic loads. CA08101001E Figure 9-1. Harmonic currents found in non-linear loads cause wave shape distortion and create added stresses on transformers. For more information visit: www.cutler-hammer.eaton.com 9 Transformers K Factor Transformers 9-42 November 2003 Single- and Three-Phase power supplies convert ac line voltage to low voltage dc. This process accomplished by charging capacitors during each line cycle with narrow pulses of current that are time-coincident with line voltage peaks. Examples of this equipment include electronic ballasts for fluorescent lighting, personal computers, printers, fax machines, electronic and medical test equipment, uninterruptible power supplies, and solid-state motor drives. Standards and Certifications Note: Nonlinear is synonymous with the term non-sinusoidal. Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. Features, Benefits and Functions 9 Vol. 1, Ref. No. [0342] ■ ■ ■ ■ ■ ■ 600 volt class standard. Three-phase, 480∆ – 208Y/120 volt standard. Single-phase, 240 x 480 volt – 120/240 volt standard. 150°C rise standard, 80ºC and 115ºC available. Three-phase neutrals sized for 200% of rated current. Electrostatic shield. Note: Electrostatic shields do not reduce harmonic levels. However, because of the nature of switching mode loads, these shields do reduce transient noise in the system which may affect sensitive computer loads. ■ Aluminum windings (copper optional). ■ Class 220°C insulation. ■ Reduced core flux density. Note: Reduced core flux prevents the core from saturation and overheating due to voltage distortions caused by harmonic currents. ■ ■ ■ ■ ■ Indoor enclosures (weathershields optional, for outdoor applications). Coils designed to minimize stray losses. K4, K13 standard. K9, K20, K30, K40, K50 optional. Low sound level (-3 dB, -5 dB) available as options. Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Options and Accessories Please refer to Page 9-120. Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hertz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one hour; and 125% load for four hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-44. Insulation System Classification Ambient 40°C 40°C 40°C 40°C + Winding Rise + Hot Spot = Temp. Class 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Cutler-Hammer ventilated transformers, Type KT, utilize a NEMA 2 rated (dripproof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Sound Levels All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Table 9-45. Average Sound Levels NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Ventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 75°C for ventilated designs. Technical Data and Specifications Please refer to Page 9-122. Product Selection Additional Product Selection information begins on Page 9-136. The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers K Factor Transformers 9-43 November 2003 Single-Phase Vol. 1, Ref. No. [0343] Table 9-46. Single Phase Selection Information — Type KS-4 — Transformers for Non-Sinusoidal Current Loads with K Factor Up to 4 kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 240 x 480 Volts to 120/240 Volts, Aluminum Windings KS-4 KS-4 KS-4 150 150 150 31-1/4 31-1/4 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 17-1/2 19-1/2 147 212 306 768 768 956 428 428 574 402 402 495 67 96 139 815 816 817 261A 261A 261A WS15 WS11 WS11 350. HT20P11S15 350. HT20P11S25 350. HT20P11S37 1,970. 2,655. 3,240. KS-4 KS-4 KS-4 150 150 150 37-5/8 42-1/8 42-1/8 22-5/8 24 24 19-1/2 23-3/8 23-3/8 340 510 600 956 1070 1070 574 610 610 495 594 594 154 232 272 818 819 820 261A 261A 261A WS11 WS16 WS16 350. HT20P11S50 800. HT20P11S75 800. HT20P11S99 3,830. 5,560. 6,910. 15 25 37.5 KS-4 KS-4 KS-4 115 115 115 30-1/4 31-1/4 37-5/8 16-7/8 22-5/8 22-5/8 15-7/8 17-1/2 19-1/2 147 212 306 768 768 956 428 428 574 402 402 495 67 67 139 815 816 817 261A 261A 261A WS15 WS11 WS11 350. HT20P11F15 350. HT20P11F25 350. HT20P11F37 2,305. 3,040. 3,740. 50 75 KS-4 KS-4 115 115 37-5/8 42-1/8 22-5/8 24 19-1/2 23-3/8 340 600 956 1070 574 610 495 594 154 272 818 820 261A 261A WS11 WS16 350. HT20P11F50 800. HT20P11F75 4,450. 6,495. 15 25 37.5 KS-4 KS-4 KS-4 80 80 80 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 212 306 340 768 956 956 428 574 574 402 495 495 67 139 154 816 817 818 261A 261A 261A WS11 WS11 WS11 350. HT20P11B15 350. HT20P11B25 350. HT20P11B37 2,680. 3,600. 4,435. 50 75 KS-4 KS-4 80 80 42-1/8 42-1/8 24 24 23-3/8 23-3/8 510 600 1070 1070 610 610 594 594 232 272 819 820 261A 261A WS16 WS16 800. HT20P11B50 800. HT20P11B75 5,210. 7,580. 15 25 37.5 50 75 100 240 x 480 Volts to 120/240 Volts, Copper Windings KS-4 KS-4 KS-4 150 150 150 30-1/4 31-1/4 37-5/8 16-7/8 22-5/8 22-5/8 15-7/8 17-1/2 19-1/2 165 237 345 768 768 956 428 428 574 402 402 495 75 108 158 815 816 817 261A 261A 261A WS15 WS11 WS11 350. HT20P11S15CU 350. HT20P11S25CU 350. HT20P11S37CU 2,760. 3,720. 4,540. KS-4 KS-4 KS-4 150 150 150 37-5/8 42-1/8 42-1/8 22-5/8 24 24 19-1/2 23-3/8 23-3/8 381 614 700 956 1070 1070 574 610 610 495 594 594 173 279 318 818 819 820 261A 261A 261A WS11 WS16 WS16 350. HT20P11S50CU 800. HT20P11S75CU 800. HT20P11S99CU 5,365. 7,785. 9,680. 15 25 37.5 KS-4 KS-4 KS-4 115 115 115 30-1/4 31-1/4 37-5/8 16-7/8 22-5/8 22-5/8 15-7/8 17-1/2 19-1/2 165 237 345 768 768 956 428 428 574 402 402 495 75 108 158 815 816 817 261A 261A 261A WS15 WS11 WS11 350. HT20P11F15CU 350. HT20P11F25CU 350. HT20P11F37CU 3,230. 4,260. 5,240. 50 75 KS-4 KS-4 115 115 37-5/8 42-1/8 22-5/8 24 19-1/2 23-3/8 381 700 956 1070 574 610 495 594 173 318 818 820 261A 261A WS11 WS16 350. HT20P11F50CU 800. HT20P11F75CU 6,230. 9,095. 15 25 37.5 KS-4 KS-4 KS-4 80 80 80 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 237 345 381 768 956 956 428 574 574 402 495 495 108 158 173 816 817 818 261A 261A 261A WS11 WS11 WS11 350. HT20P11B15CU 350. HT20P11B25CU 350. HT20P11B37CU 3,750. 5,045. 6,210. 50 75 KS-4 KS-4 80 80 42-1/8 42-1/8 24 24 23-3/8 23-3/8 614 700 1070 1070 610 610 594 594 279 318 819 820 261A 261A WS16 WS16 800. HT20P11B50CU 800. HT20P11B75CU 7,300. 10,615. 15 25 37.5 50 75 100 1@ +5%, 2@ -5% at 240 volt primary; 2@ +2.5%, 4@ -2.5% at 480 volt primary. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers K Factor Transformers 9-44 November 2003 Single-Phase Vol. 1, Ref. No. [0344] Table 9-47. Single Phase Selection Information — Type KS-13 — Transformers for Non-Sinusoidal Current Loads with K Factor Up to 13 kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 240 x 480 Volts to 120/240 Volts, Aluminum Windings 9 15 25 37.5 KS-13 150 KS-13 150 KS-13 150 30-1/4 37-5/8 37-5/8 16-7/8 22-5/8 22-5/8 15-7/8 19-1/2 19-1/2 147 306 340 768 956 956 428 574 574 402 495 495 67 139 154 815 817 818 261A 261A 261A WS15 WS11 WS11 350. NT20P11S15 350. NT20P11S25 350. NT20P11S37 2,620. 3,520. 4,320. 50 75 KS-13 150 KS-13 150 42-1/8 42-1/8 24 24 23-3/8 23-3/8 510 600 1070 1070 610 610 594 594 232 272 819 820 261A 261A WS16 WS16 800. NT20P11S50 800. NT20P11S75 5,100. 7,400. 15 25 37.5 KS-13 115 KS-13 115 KS-13 115 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 212 306 340 768 956 956 428 574 574 402 495 495 67 139 154 816 817 818 261A 261A 261A WS11 WS11 WS11 350. NT20P11F15 350. NT20P11F25 350. NT20P11F37 3,060. 4,050. 4,980. 50 75 KS-13 115 KS-13 115 42-1/8 42-1/8 24 24 23-3/8 23-3/8 510 600 1070 1070 610 610 594 594 232 272 819 820 261A 261A WS16 WS16 800. NT20P11F50 800. NT20P11F75 5,920. 8,660. 15 25 37.5 KS-13 KS-13 KS-13 80 80 80 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 212 306 340 768 956 956 428 574 574 402 495 495 67 139 154 816 817 818 261A 261A 261A WS11 WS11 WS11 350. NT20P11B15 350. NT20P11B25 350. NT20P11B37 3,560. 4,800. 5,900. 50 75 KS-13 KS-13 80 80 42-1/8 42-1/8 24 24 23-3/8 23-3/8 510 600 1070 1070 610 610 594 594 232 272 819 820 261A 261A WS16 WS16 800. NT20P11B50 800. NT20P11B75 6,940. 10,100. 240 x 480 Volts to 120/240 Volts, Copper Windings 15 25 37.5 KS-13 150 KS-13 150 KS-13 150 30-1/4 37-5/8 37-5/8 16-7/8 22-5/8 22-5/8 15-7/8 19-1/2 19-1/2 165 345 381 768 956 956 428 574 574 402 495 495 75 158 173 815 817 818 261A 261A 261A WS15 WS11 WS11 350. NT20P11S15CU 350. NT20P11S25CU 350. NT20P11S37CU 3,670. 4,930. 6,050. 50 75 KS-13 150 KS-13 150 42-1/8 42-1/8 24 24 23-3/8 23-3/8 614 700 1070 1070 610 610 594 594 279 318 819 820 261A 261A WS16 WS16 800. NT20P11S50CU 800. NT20P11S75CU 7,140. 10,360. 15 25 37.5 KS-13 115 KS-13 115 KS-13 115 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 237 345 381 768 956 956 428 574 574 402 495 495 108 158 173 816 817 818 261A 261A 261A WS11 WS11 WS11 350. NT20P11F15CU 350. NT20P11F25CU 350. NT20P11F37CU 4,285. 5,670. 6,975. 50 75 KS-13 115 KS-13 115 42-1/8 42-1/8 24 24 23-3/8 23-3/8 614 700 1070 1070 610 610 594 594 279 318 819 820 261A 261A WS16 WS16 800. NT20P11F50CU 800. NT20P11F75CU 8,290. 12,125. 15 25 37.5 KS-13 KS-13 KS-13 80 80 80 31-1/4 37-5/8 37-5/8 22-5/8 22-5/8 22-5/8 17-1/2 19-1/2 19-1/2 237 345 381 768 956 956 428 574 574 402 495 495 108 158 173 816 817 818 261A 261A 261A WS11 WS11 WS11 350. NT20P11B15CU 350. NT20P11B25CU 350. NT20P11B37CU 4,985. 6,720. 8,260. 50 75 KS-13 KS-13 80 80 42-1/8 42-1/8 24 24 23-3/8 23-3/8 614 700 1070 1070 610 610 594 594 279 318 819 820 261A 261A WS16 WS16 800. NT20P11B50CU 800. NT20P11B75CU 9,720. 14,140. 1@ +5%, 2@ -5% at 240 volt primary; 2@ +2.5%, 4@ -2.5% at 480 volt primary. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers K Factor Transformers 9-45 November 2003 Three-Phase Vol. 1, Ref. No. [0345] Table 9-48. Type KT-4 — Transformers for Non-Sinusoidal Current Loads with K Factor Up to 4 kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 208Y/120 Volts 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 230 310 765 765 765 511 511 511 359 359 359 104 104 140 FR910A FR910A FR912A 283B 283B 283B WS31 WS31 WS31 350. H48M28T15A 350. H48M28T30A 350. H48M28T45A 1,850. 2,570. 3,090. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 39-3/8 39-3/8 56 26-1/8 26-1/8 31-1/4 19-1/8 19-1/8 24-1/4 480 600 1100 1000 1000 1422 663 663 793 485 485 616 217 272 499 FR914B FR915B FR917 283B 283B 283B WS33 WS33 WS34 350. H48M28T75A 350. H48M28T12A 800. H48M28T49A 4,360. 5,975. 8,015. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 56 75 75 31-1/4 44-1/2 44-1/2 24-1/4 36 36 1100 2400 2800 1422 1905 1905 793 1130 1130 616 914 914 499 1088 1270 FR917 FR919 FR919 283B 292A 292A WS34 WS35 WS35 800. H48M28T22A 1,360. H48M28T33B 1,360. H48M28T55A 11,910. 16,330. 25,060. 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 230 480 765 765 1000 511 511 663 359 359 485 104 104 217 FR910A FR910A FR914B 283B 283B 283B WS31 WS31 WS33 350. H48M28F15A 350. H48M28F30A 350. H48M28F45A 2,040. 2,820. 3,400. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 663 712 793 485 585 616 272 344 499 FR915B FR916A FR917 283B 283B 283B WS33 WS19 WS34 350. H48M28F75A 350. H48M28F12A 800. H48M28F49A 4,690. 6,540. 8,530. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 62-1/4 75 90 31-1/4 44-1/2 69 30-1/4 36 42 1600 2400 4500 1581 1905 2286 794 1130 1752 768 914 1066 728 1088 2041 FR918A FR919 FR922 283B 292A 292A WS34 WS35 WS36 800. H48M28F22A 1,360. H48M28F33A 1,360. H48M28F55A 13,040. 19,060. 27,560. 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 80 80 80 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 663 359 359 485 104 140 217 FR910A FR912A FR914B 283B 283B 283B WS31 WS31 WS33 350. H48M28B15A 350. H48M28B30A 350. H48M28B45A 2,350. 2,970. 4,475. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 80 80 80 39-3/8 56 56 26-1/8 31-1/4 31-1/4 19-1/8 24-1/4 24-1/4 600 1100 1100 1000 1422 1422 663 793 793 485 616 616 272 499 499 FR915B FR917 FR917 283B 283B 283B WS33 WS34 WS34 350. H48M28B75A 800. H48M28B12A 800. H48M28B49A 5,680. 8,000. 11,660. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 80 80 80 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 35-3/4 1600 2400 3600 1581 1905 1905 794 1130 1129 768 914 908 728 1088 1636 FR918A FR919 FR920 283B 292A 292A WS34 WS35 WS35 800. H48M28B22A 1,360. H48M28B33A 1,360. H48M28B55A 16,430. 21,200. 32,480. 300 300 370 765 765 765 511 511 511 359 359 359 136 136 168 FR910A 283B FR910A 283B FR912A 283B WS31 WS31 WS31 350. H48M28T15CU 350. H48M28T30CU 350. H48M28T45CU 2,260. 2,750. 3,545. 306 306 545 FR914B FR915B FR917 283B 283B 283B WS33 WS33 WS34 350. H48M28T75CU 350. H48M28T12CU 800. H48M28T49CU 5,215. 6,315. 9,020. 545 FR917 283B 977 FR918A 292A 1636 FR919 292A WS34 WS34 WS35 800. H48M28T22CU 800. H48M28T33CU 1,360. H48M28T55CU 12,510. 18,530. 26,300. 480 ∆ Volts to 208Y/120 Volts (Copper Windings) 15 30 45 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 75 112.5 150 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 150 150 150 39-3/8 39-3/8 56 26-1/8 26-1/8 31-1/4 19-1/8 19-1/8 24-1/4 675 1000 675 1000 1200 1422 663 663 793 485 485 616 225 300 500 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1200 1422 2150 1581 3600 1905 793 794 1130 616 768 914 15 30 45 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 115 115 115 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 765 765 1000 511 511 663 359 359 485 136 136 261 FR910A 283B FR910A 283B FR914B 283B WS31 WS31 WS33 350. H48M28F15CU 350. H48M28F30CU 350. H48M28F45CU 2,770. 3,850. 4,635. 75 112.5 150 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 115 115 115 39-3/8 46-1/2 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 675 1000 850 1171 1200 1422 663 712 793 485 585 616 306 386 545 FR915B 283B FR916A 283B FR917 283B WS33 WS19 WS34 350. H48M28F75CU 350. H48M28F12CU 800. H48M28F49CU 5,420. 7,075. 9,690. 225 300 500 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 115 115 115 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 35-3/4 2150 1581 3100 1905 3600 1905 794 1130 1129 768 914 908 977 FR918A 283B 1409 FR919 292A 1636 FR920 292A WS34 WS35 WS35 800. H48M28F22CU 1,360. H48M28F33CU — H48M28F55CU 15,675. 22,860. 28,940. 15 30 45 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 80 80 80 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 765 765 1000 511 511 663 359 359 485 136 168 261 FR910A 283B FR912A 283B FR914B 283B WS31 WS31 WS33 350. H48M28B15CU 350. H48M28B30CU 350. H48M28B45CU 3,145. 4,360. 5,370. 75 112.5 150 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 80 80 80 39-3/8 56 56 26-1/8 31-1/4 31-1/4 19-1/8 24-1/4 24-1/4 675 1000 1200 1422 1200 1422 663 793 793 485 616 616 306 545 545 FR915B FR917 FR917 283B 283B 283B WS33 WS34 WS34 350. H48M28B75CU 800. H48M28B12CU 800. H48M28B49CU 6,760. 9,240. 12,060. 225 300 500 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 80 80 80 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 35-3/4 2150 1581 3100 1905 3600 1905 794 1130 1129 768 914 908 977 FR918A 283B 1409 FR919 292A 1636 FR920 292A WS34 WS35 WS35 800. H48M28B22CU 1,360. H48M28B33CU 1,360. H48M28B55CU 18,050. 26,100. 34,200. 300 300 575 300 370 575 Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. Note: For Energy Star labeled K factor transformers, contact your local Cutler-Hammer sales office. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers K Factor Transformers 9-46 November 2003 Three-Phase Vol. 1, Ref. No. [0346] Table 9-49. Type KT-13 — Transformers for Non-Sinusoidal Current Loads with K Factor Up to 13 kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 208Y/120 Volts 9 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 663 359 359 485 104 140 217 FR910A FR912A FR914B 283B 283B 283B WS31 WS31 WS33 350. N48M28T15A 350. N48M28T30A 350. N48M28T45A 1,970. 2,845. 3,370. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 663 712 793 485 585 616 272 344 499 FR915B FR916A FR917 283B 283B 283B WS33 WS19 WS34 350. N48M28T75A 350. N48M28T12A 800. N48M28T49A 4,660. 6,535. 8,780. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 62-1/4 75 90 31-1/4 44-1/2 69 30-1/4 36 42 1600 2400 4500 1581 1905 2286 794 1130 1752 768 914 1066 728 1088 2041 FR918A FR919 FR922 283B 292A 292A WS34 WS35 WS36 800. N48M28T22A 1,360. N48M28T33A 1,360. N48M28T55A 12,140. 17,870. 27,570. 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 663 359 359 485 104 140 217 FR910A FR912A FR914B 283B 283B 283B WS31 WS31 WS33 350. N48M28F15A 350. N48M28F30A 350. N48M28F45A 2,410. 2,985. 3,890. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 663 712 793 485 585 616 272 344 499 FR915B FR916A FR917 283B 283B 283B WS33 WS19 WS34 350. N48M28F75A 350. N48M28F12A 800. N48M28F49A 5,315. 8,120. 9,560. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 62-1/4 75 90 31-1/4 44-1/2 69 30-1/4 36 42 1600 2400 4500 1581 1905 2286 794 1130 1752 768 914 1066 728 1088 2041 FR918A FR919 FR922 283B 292A 292A WS34 WS35 WS36 800. N48M28F22A 1,360. N48M28F33A 1,360. N48M28F55A 13,390. 20,100. 30,400. 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 80 80 80 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 663 359 359 485 104 140 217 FR910A FR912A FR914B 283B 283B 283B WS31 WS31 WS33 350. N48M28B15A 350. N48M28B30A 350. N48M28B45A 2,840. 3,730. 4,755. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 80 80 80 46-1/8 56 62-1/4 28 31-1/4 31-1/4 23 24-1/4 30-1/4 760 1100 1600 1171 1422 1581 712 793 794 585 616 768 344 499 728 FR916A FR917 FR918A 283B 283B 283B WS33 WS34 WS34 350. N48M28B75A 350. N48M28B12A 800. N48M28B49A 6,160. 8,840. 12,565. 225 300 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT 80 80 75 75 44-1/2 44-1/2 36 36 2400 3600 1905 1905 1130 1130 914 914 1088 1636 FR919 FR919 292A 292A WS35 WS35 1,360. N48M28B22A 1,360. N48M28B33CU 17,140. 26,780. 480 ∆ Volts to 208Y/120 Volts (Copper Windings) 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 300 370 575 65 765 1000 511 511 663 359 359 485 136 168 261 FR910A FR912A FR914B 283B 283B 283B WS31 WS31 WS33 350. N48M28T15CU 350. N48M28T30CU 350. N48M28T45CU 2,540. 2,890. 4,270. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 675 850 1200 1000 1171 1422 663 712 793 485 585 616 306 386 545 FR915B FR916A FR917 283B 283B 283B WS33 WS19 WS34 350. N48M28T75CU 350. N48M28T12CU 800. N48M28T49CU 5,690. 7,460. 9,770. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 62-1/4 75 31-1/4 44-1/2 30-1/4 36 2150 3100 1581 1905 794 1130 768 914 977 1409 FR918A FR919 283B 292A WS34 WS35 800. N48M28T22CU 1,360. N48M28T33CU — N48M28T55CU 13,440. 22,330. 28,930. 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 300 370 575 65 765 1000 511 511 663 359 359 485 136 168 261 FR910A FR912A FR914B 283B 283B 283B WS31 WS31 WS33 350. N48M28F15CU 350. N48M28F30CU 350. N48M28F45CU 2,785. 3,295. 4,430. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 675 850 1200 1000 1171 1422 663 712 793 485 585 616 360 386 545 FR915B FR916A FR917 283B 283B 283B WS33 WS19 WS34 350. N48M28F75CU 350. N48M28F12CU 800. N48M28F49CU 6,290. 9,025. 11,950. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 62-1/4 75 31-1/4 44-1/2 30-1/4 36 2150 3100 1581 1905 794 1130 768 914 977 1409 FR918A FR919 283B 292A WS34 WS35 800. N48M28F22CU 1,360. N48M28F33CU — N48M28F55CU 16,300. 24,560. 31,850. 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 80 80 80 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 300 370 575 65 765 1000 511 511 663 359 359 485 136 168 261 FR910A FR912A FR914B 283B 283B 283B WS31 WS31 WS33 350. N48M28B15CU 350. N48M28B30CU 350. N48M28B45CU 3,125. 4,140. 5,570. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 80 80 80 46-1/8 56 62-1/4 28 31-1/4 31-1/4 23 24-1/4 30-1/4 950 1200 2150 1171 1422 1581 712 793 794 585 616 768 431 545 977 FR916A FR917 FR917 283B 283B 283B WS33 WS34 WS34 350. N48M28B75CU 350. N48M28B12CU 800. N48M28B49CU 7,100. 10,270. 13,480. 225 300 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT 80 80 75 75 44-1/2 44-1/2 36 36 3100 3600 1905 1905 1130 1130 914 914 1409 1636 FR919 FR919 292A 292A WS35 WS35 1,360. N48M28B22CU 1,360. N48M28B33CU 20,520. 26,780. Refer to your Cutler-Hammer sales office. Not Seismic Qualified. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. Note: For Energy Star labeled K factor transformers, contact your local Cutler-Hammer sales office. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers K Factor Transformers 9-47 November 2003 Three-Phase Vol. 1, Ref. No. [0347] Table 9-50. Type KT-20 — Transformers for Non-Sinusoidal Current Loads with K Factor Up to 20 kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 208Y/120 Volts 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 663 358 358 485 104 FR910A 140 FR912A 217 FR914B 283B 283B 283B WS31 WS31 WS33 350. G48M28T15A 350. G48M28T30A 350. G48M28T45A 2,050. 3,010. 3,960. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 663 712 793 485 585 616 272 FR915B 344 FR916A 499 FR917 283B 283B 283B WS33 WS19 WS34 350. G48M28T75A 350. G48M28T12A 800. G48M28T49A 5,600. 8,780. 9,860. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 150 150 150 62-1/4 75 31-1/4 44-1/2 30-1/4 36 1600 2400 1581 1905 794 1130 768 914 728 FR918A 1088 FR919 283B 292A WS34 WS35 800. G48M28T22A 1,360. G48M28T33A — G48M28T55A 13,420. 18,530. 30,700. 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 663 358 358 485 104 FR910A 140 FR912A 217 FR914B 283B 283B 283B WS31 WS31 WS33 350. G48M28F15A 350. G48M28F30A 350. G48M28F45A 2,655. 3,460. 4,560. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 46-1/8 56 62-1/4 28 31-1/4 31-1/4 23 24-1/4 30-1/4 780 1100 1600 1171 1422 1581 712 793 794 585 616 768 354 FR916A 499 FR917 728 FR918A 283B 283B 283B WS33 WS34 WS34 350. G48M28F75A 350. G48M28F12A 800. G48M28F49A 6,440. 9,220. 10,850. 225 300 500 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 115 115 115 75 75 44-1/2 44-1/2 36 36 2400 3100 1905 1905 1130 1130 914 914 283B 292A WS35 WS35 800. G48M28F22A 1,360. G48M28F33A — G48M28F55A 15,600. 20,650. 35,300. 15 30 45 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 80 80 80 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 230 480 600 765 1000 1000 511 663 663 358 485 485 140 FR912A 217 FR914B 272 FR915B 283B 283B 283B WS31 WS31 WS31 350. G48M28B15A 350. G48M28B30A 350. G48M28B45A 2,990. 4,060. 5,350. 75 112.5 150 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT KT 80 80 80 46-1/8 56 62-1/4 28 31-1/4 31-1/4 23 24-1/4 30-1/4 860 1100 1600 1171 1422 1581 712 793 794 585 616 768 389 FR916A 499 FR917 728 FR918A 283B 283B 283B WS33 WS34 WS34 350. G48M28B75A 350. G48M28B12A 800. G48M28B49A 7,560. 9,860. 13,400. 225 300 2@+2.5% 4@-2.5% 2@+2.5% 4@-2.5% KT KT 80 80 75 44-1/2 36 2400 1905 1130 914 283B WS35 800. G48M28B22A — G48M28B33A 19,800. 25,700. 1088 FR919 1315 FR920 1088 FR919 480 ∆ Volts to 208Y/120 Volts (Copper Windings) 15 30 45 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 150 150 150 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 300 370 575 765 765 1000 511 511 663 358 358 485 136 FR910A 168 FR912A 261 FR914B 283B 283B 283B WS31 WS31 WS33 350. G48M28T15CU 350. G48M28T30CU 350. G48M28T45CU 2,770. 4,120. 5,430. 75 112.5 150 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 150 150 150 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 675 850 1200 1000 1171 1422 663 712 793 485 585 616 306 FR915B 386 FR916A 545 FR917 283B 283B 283B WS33 WS19 WS34 350. G48M28T75CU 350. G48M28T12CU 800. G48M28T49CU 7,660. 11,400. 12,820. 225 300 500 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 150 150 150 62-1/4 75 31-1/4 44-1/2 30-1/4 36 2150 3100 1581 1905 794 1130 768 914 977 FR918A 1409 FR919 283B 292A WS34 WS35 800. G48M28T22CU 1,360. G48M28T33CU — G48M28T55CU 17,400. 24,560. 39,900. 15 30 45 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 115 115 115 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 300 370 575 765 765 1000 511 511 663 358 358 485 136 FR910A 168 FR912A 261 FR914B 283B 283B 283B WS31 WS31 WS33 350. G48M28F15CU 350. G48M28F30CU 350. G48M28F45CU 3,180. 4,665. 6,140. 75 112.5 150 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 115 115 115 46-1/8 56 62-1/4 28 31-1/4 31-1/4 23 24-1/4 30-1/4 780 1200 2150 1171 1422 1581 712 793 794 585 616 768 354 FR916A 545 FR917 977 FR918A 283B 283B 283B WS33 WS34 WS34 350. G48M28F75CU 350. G48M28F12CU 800. G48M28F49CU 8,680. 12,300. 13,800. 225 300 500 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 115 115 115 75 75 44-1/2 44-1/2 36 36 3100 3600 1905 1905 1130 1130 914 914 283B 292A WS35 WS35 800. G48M28F22CU 1,360. G48M28F33CU — G48M28F55CU 18,800. 27,000. 46,000. 15 30 45 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 80 80 80 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 370 575 675 765 1000 1000 511 663 663 358 485 485 168 FR912A 261 FR914B 306 FR915B 283B 283B 283B WS31 WS31 WS33 350. G48M28B15CU 350. G48M28B30CU 350. G48M28B45CU 3,480. 5,270. 6,740. 75 112.5 150 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 80 80 80 46-1/8 56 62-1/4 28 31-1/4 31-1/4 23 24-1/4 30-1/4 860 1200 2150 1171 1422 1581 712 793 794 585 616 768 389 FR916A 545 FR917 977 FR918A 283B 283B 283B WS33 WS34 WS34 350. G48M28B75CU 350. G48M28B12CU 800. G48M28B49CU 9,520. 14,050. 15,780. 225 300 2@+2.5% 4@-2.5% KT 2@+2.5% 4@-2.5% KT 80 80 75 44-1/2 36 3100 1905 1130 914 292A WS35 1,360. G48M28B22CU — G48M28B33CU 21,470. 29,650. 1409 FR919 1636 FR920 1409 FR919 Refer to your Cutler-Hammer sales office. Not Seismic Qualified. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. Note: For Energy Star labeled K factor transformers, contact your local Cutler-Hammer sales office. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers K Factor Transformers 9-48 November 2003 Three-Phase Vol. 1, Ref. No. [0348] Table 9-51. Type KT-4 — Transformers for Non-Sinusoidal Current Loads with K Factor Up to 4 kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 208 ∆ Volts to 208Y/120 Volts 15 30 45 75 112.5 150 225 300 15 30 45 75 112.5 150 225 300 9 15 30 45 75 112.5 150 225 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 150 150 150 150 30-1/8 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 14-1/8 19-1/8 1@+5% 1@+5% 1@+5% — 2@-5% 2@-5% 2@-5% 2@-5% KT KT KT KT 150 150 150 150 39-3/8 56 62-1/4 75 26-1/8 31-1/4 31-1/4 44-1/2 19-1/8 24-1/4 30-1/4 36 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 115 115 115 115 30-1/8 30-1/8 39-3/8 39-3/8 20-1/8 20-1/8 26-1/8 26-1/8 14-1/8 14-1/8 19-1/8 19-1/8 1@+5% 1@+5% 1@+5% — 2@-5% 2@-5% 2@-5% 2@-5% KT KT KT KT 115 115 115 115 46-1/8 56 62-1/4 75 28 31-1/4 31-1/4 44-1/2 23 24-1/4 30-1/4 36 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 80 80 80 80 30-1/8 30-1/8 39-3/8 39-3/8 20-1/8 20-1/8 26-1/8 26-1/8 1@+5% 1@+5% 1@+5% 2@-5% 2@-5% 2@-5% KT KT KT 80 80 80 56 56 75 31-1/4 31-1/4 44-1/2 230 765 230 765 310 765 480 1000 511 511 511 664 359 359 359 486 104 104 141 218 FR910A FR910A FR912A FR914B 283A 283A 283A 283A WS31 WS31 WS31 WS33 350. 350. 350. 350. H29M28T15A H29M28T30A H29M28T45A H29M28T75A 2,590. 3,590. 4,320. 6,100. 1000 1422 1581 1905 664 794 794 1130 486 616 768 914 273 499 728 1089 FR915B FR917 FR918A FR919 325A 287A 287A 297B WS33 WS34 WS34 WS35 350. 800. 800. 1,360. H29R28T12A H29R28T49A H29R28T22A H29G28T33A 7,940. 11,200. 16,670. 22,800. 230 765 230 765 480 1000 600 1000 511 511 664 664 359 359 486 486 104 104 218 273 FR910A FR910A FR914B FR915B 283A 283A 283A 283A WS31 WS31 WS33 WS33 350. 350. 350. 350. H29M28F15A H29M28F30A H29M28F45A H29M28F75A 2,850. 3,940. 4,750. 6,550. 1171 1422 1581 1905 712 794 794 1130 585 616 768 914 345 499 728 1089 FR916A FR917 FR918A FR919 325A 287A 287A 297B WS19 WS34 WS34 WS35 350. 800. 800. 1,360. H29R28F12A H29R28F49A H29R28F22A H29G28F33A 9,150. 11,900. 18,200. 26,600. 14-1/8 14-1/8 19-1/8 19-1/8 230 765 310 765 480 1000 600 1000 511 511 664 664 359 359 486 486 104 141 218 273 FR910A FR912A FR914B FR915B 283A 283A 283A 283A WS31 WS31 WS33 WS33 350. 350. 350. 350. H29M28B15A H29M28B30A H29M28B45A H29M28B75A 3,290. 4,150. 6,260. 7,950. 24-1/4 24-1/4 36 1100 1422 1100 1422 2400 1905 794 794 1130 616 616 914 287A 287A 297B WS34 WS34 WS35 800. H29R28B12A 800. H29R28B49A — H29R28B22A 11,100. 16,300. 23,000. 600 1100 1600 2400 760 1100 1600 2400 499 FR917 499 FR917 1089 FR919 Table 9-52. Type KT-13 — Transformers for Non-Sinusoidal Current Loads with K Factor Up to 13 kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 208 ∆ Volts to 208Y/120 Volts 15 30 45 75 112.5 150 225 300 15 30 45 75 112.5 150 225 300 15 30 45 75 112.5 150 225 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 150 150 150 150 30-1/8 30-1/8 39-3/8 39-3/8 20-1/8 20-1/8 26-1/8 26-1/8 14-1/8 14-1/8 19-1/8 19-1/8 1@+5% 1@+5% 1@+5% — 2@-5% 2@-5% 2@-5% 2@-5% KT KT KT KT 150 150 150 150 46-1/8 56 62-1/4 75 28 31-1/4 31-1/4 44-1/2 23 24-1/4 30-1/4 36 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 115 115 115 115 30-1/8 30-1/8 39-3/8 39-3/8 20-1/8 20-1/8 26-1/8 26-1/8 14-1/8 14-1/8 19-1/8 19-1/8 1@+5% 1@+5% 1@+5% — 2@-5% 2@-5% 2@-5% 2@-5% KT KT KT KT 115 115 115 115 46-1/8 56 62-1/4 75 28 31-1/4 31-1/4 44-1/2 23 24-1/4 30-1/4 36 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 80 80 80 80 30-1/8 30-1/8 39-3/8 46-1/8 20-1/8 20-1/8 26-1/8 28 1@+5% 1@+5% — 2@-5% 2@-5% 2@-5% KT KT KT 80 80 80 56 62-1/4 75 31-1/4 31-1/4 44-1/2 230 765 310 765 480 1000 600 1000 511 511 664 664 359 359 486 486 104 141 218 273 FR910A FR912A FR914B FR915B 283A 283A 283A 283A WS31 WS31 WS33 WS33 350. 350. 350. 350. N29M28T15A N29M28T30A N29M28T45A N29M28T75A 2,760. 3,980. 4,720. 6,520. 1171 1422 1581 1905 712 794 794 1130 585 616 768 914 372 499 728 1089 FR916A FR917 FR918A FR919 287A 287A 287A 297B WS19 WS34 WS34 WS35 350. 800. 800. 1,360. N29R28T12A N29R28T49A N29R28T22A N29G28T33A 9,150. 12,300. 17,000. 25,000. 230 765 310 765 480 1000 600 1000 511 511 664 664 359 359 486 486 104 141 218 273 FR910A FR912A FR914B FR915B 283A 283A 283A 283A WS31 WS31 WS33 WS33 350. 350. 350. 350. N29M28F15A N29M28F30A N29M28F45A N29M28F75A 3,175. 4,580. 5,430. 7,500. 1171 1422 1581 1905 712 794 794 1130 585 616 768 914 389 499 728 1089 FR916A FR917 FR918A FR919 287A 287A 287A 297B WS19 WS34 WS34 WS35 350. 800. 800. 1,360. N29R28F12A N29R28F49A N29R28F22A N29G28F33A 10,520. 14,150. 19,550. 28,700. 14-1/8 14-1/8 19-1/8 23 230 765 310 765 480 1000 820 1171 511 511 664 712 359 359 486 585 104 141 218 389 FR910A FR912A FR914B FR916A 283A 283A 283A 283A WS31 WS31 WS33 WS33 350. 350. 350. 350. N29M28B15A N29M28B30A N29M28B45A N29M28B75A 3,720. 5,370. 6,370. 8,800. 24-1/4 30-1/4 36 1200 1422 1600 1581 2400 1905 794 794 1130 616 768 914 544 FR917 728 FR918A 1089 FR919 287A 287A 297B WS34 WS34 WS35 350. N29R28B12A 800. N29R28B49A 1,360. N29G28B22A 12,350. 16,600. 22,900. 820 1100 1600 2400 860 1100 1600 2400 Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. Note: For Energy Star labeled K factor transformers, contact your local Cutler-Hammer sales office. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers K Factor Transformers 9-49 November 2003 Three-Phase Vol. 1, Ref. No. [0349] Table 9-53. Type KT-4 — Transformers for Non-Sinusoidal Current Loads with K Factor Up to 4 kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 480Y/277 Volts 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 150 150 150 150 30-1/8 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 14-1/8 19-1/8 230 230 310 480 765 765 765 1000 511 511 511 664 359 359 359 486 104 104 141 218 FR910A FR910A FR912A FR914B 283B 283B 283B 283B WS31 WS31 WS31 WS33 350. 350. 350. 350. H48M47T15A H48M47T30A H48M47T45A H48M47T75A 2,220. 3,100. 3,700. 5,230. 112.5 150 225 300 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 150 150 150 150 39-3/8 56 62-1/4 75 26-1/8 31-1/4 31-1/4 44-1/2 19-1/8 24-1/4 30-1/4 36 600 1100 1600 2400 1000 1422 1581 1905 664 794 794 1130 486 616 768 914 273 499 728 1089 FR915B FR917 FR918A FR919 283B 283B 283B 292A WS33 WS34 WS34 WS35 350. 800. 800. 1,360. H48M47T12A H48M47T49A H48M47T22A H48M47T33A 7,170. 9,610. 14,290. 19,590. 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 115 115 115 115 30-1/8 30-1/8 39-3/8 39-3/8 20-1/8 20-1/8 26-1/8 26-1/8 14-1/8 14-1/8 19-1/8 19-1/8 230 230 480 600 765 765 1000 1000 511 511 664 664 359 359 486 486 104 104 218 273 FR910A FR910A FR914B FR915B 283B 283B 283B 283B WS31 WS31 WS33 WS33 350. 350. 350. 350. H48M47F15A H48M47F30A H48M47F45A H48M47F75A 2,550. 3,560. 4,250. 6,010. 112.5 150 225 300 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 115 115 115 115 46-1/8 56 62-1/4 75 28 31-1/4 31-1/4 44-1/2 23 24-1/4 30-1/4 36 960 1100 1600 2400 1171 1422 1581 1905 712 794 794 1130 585 616 768 914 434 499 728 1089 FR916A FR917 FR918A FR919 283B 283B 283B 292A WS19 WS34 WS34 WS35 350. 800. 800. 1,360. H48M47F12A H48M47F49A H48M47F22A H48M47F33A 8,250. 11,060. 16,440. 22,540. 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 80 80 80 80 30-1/8 30-1/8 39-3/8 39-3/8 20-1/8 20-1/8 26-1/8 26-1/8 14-1/8 14-1/8 19-1/8 19-1/8 230 310 480 600 765 765 1000 1000 511 511 664 664 359 359 486 486 104 141 218 273 FR910A FR912A FR914B FR915B 283B 283B 283B 283B WS31 WS31 WS33 WS33 350. 350. 350. 350. H48M47B15A H48M47B30A H48M47B45A H48M47B75A 2,995. 4,185. 4,990. 7,050. 112.5 150 225 300 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 80 80 80 80 56 56 62-1/4 75 31-1/4 31-1/4 31-1/4 44-1/2 24-1/4 24-1/4 30-1/4 36 1100 1100 1600 2400 1422 1422 1581 1905 794 794 794 1130 616 616 768 914 499 499 728 1089 FR917 FR917 FR918A FR919 283B 283B 283B 292A WS34 WS34 WS34 WS35 800. 800. 800. 1,360. H48M47B12A H48M47B49A H48M47B22A H48M47B33A 9,680. 12,970. 19,290. 26,440. Table 9-54. Type KT-13 — Transformers for Non-Sinusoidal Current Loads with K Factor Up to 13 kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Dimensions (mm) Wt. Lbs. H kg W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 480Y/277 Volts 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 150 150 150 150 30-1/8 30-1/8 39-3/8 39-3/8 20-1/8 20-1/8 26-1/8 26-1/8 14-1/8 14-1/8 19-1/8 19-1/8 112.5 150 225 300 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 150 150 150 150 46-1/8 56 62-1/4 75 28 31-1/4 31-1/4 44-1/2 23 24-1/4 30-1/4 36 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 115 115 115 115 30-1/8 30-1/8 39-3/8 39-3/8 20-1/8 20-1/8 26-1/8 26-1/8 14-1/8 14-1/8 19-1/8 19-1/8 112.5 150 225 300 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 115 115 115 115 46-1/8 56 62-1/4 75 28 31-1/4 31-1/4 44-1/2 23 24-1/4 30-1/4 36 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 80 80 80 80 30-1/8 30-1/8 39-3/8 46-1/8 20-1/8 20-1/8 26-1/8 28 14-1/8 14-1/8 19-1/8 23 112.5 150 225 300 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% KT KT KT KT 80 80 80 80 56 62-1/4 75 75 31-1/4 31-1/4 44-1/2 44-1/2 24-1/4 30-1/4 36 36 230 765 310 765 480 1000 600 1000 511 511 664 664 359 359 486 486 104 141 218 273 FR910A FR912A FR914B FR915B 283B 283B 283B 283B WS31 WS31 WS33 WS33 350. 350. 350. 350. N48M47T15A N48M47T30A N48M47T45A N48M47T75A 2,360. 3,415. 4,040. 5,590. 1171 1422 1581 1905 712 794 794 1130 585 616 768 914 345 499 728 1089 FR916A FR917 FR918A FR919 283B 283B 283B 292A WS19 WS34 WS34 WS35 350. 800. 800. 1,360. N48M47T12A N48M47T49A N48M47T22A N48M47T33A 7,840. 10,530. 14,560. 21,440. 230 765 310 765 480 1000 600 1000 511 511 664 664 359 359 486 486 104 141 218 273 FR910A FR912A FR914B FR915B 283B 283B 283B 283B WS31 WS31 WS33 WS33 350. 350. 350. 350. N48M47F15A N48M47F30A N48M47F45A N48M47F75A 2,715. 3,930. 4,650. 6,430. 1171 1422 1581 1905 712 794 794 1130 585 616 768 914 345 499 728 1089 FR916A FR917 FR918A FR919 283B 283B 283B 292A WS19 WS34 WS34 WS35 350. 800. 800. 1,360. N48M47F12A N48M47F49A N48M47F22A N48M47F33A 9,020. 12,120. 16,750. 24,670. 230 765 310 765 480 1000 760 1171 511 511 664 712 359 359 486 585 104 141 218 345 FR910A FR912A FR914B FR916A 283B 283B 283B 283B WS31 WS31 WS33 WS33 350. 350. 350. 350. N48M47B15A N48M47B30A N48M47B45A N48M47B75A 3,180. 4,600. 5,450. 7,540. 794 794 1130 1130 616 768 914 914 499 728 1089 1636 FR917 FR918A FR919 FR919 283B 283B 292A 292A WS34 WS34 WS35 WS35 350. 800. 1,360. 1,360. 760 1100 1600 2400 760 1100 1600 2400 1100 1600 2400 3600 1422 1581 1905 1905 N48M47B12A N48M47B49A N48M47B22A N48M47B33CU 10,580. 14,200. 19,650. 36,440. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. Note: For Energy Star labeled K factor transformers, contact your local Cutler-Hammer sales office. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Drive Isolation Transformers 9-50 November 2003 Three-Phase Three-Phase, Type MD, 60 Hz Vol. 1, Ref. No. [0350] Features, Benefits and Functions Options and Accessories ■ ■ ■ ■ ■ ■ Type MD 9 ■ Product Description ■ Suitable for indoor or outdoor applications (with weathershield). ■ Ventilated enclosures. ■ 220°C Insulation system, 150°C Rise standard (self extinguishing). ■ Available in ratings from 7.5 through 1500 kVA. ■ ■ ■ Application Description Drive isolation transformers are specifically designed for use with ac and dc adjustable speed drives. Two winding drive isolation transformers provide: ■ ■ ■ ■ Electrical isolation between the incoming line and the drive circuitry. ■ Voltage conversion of input line to standard drive input voltages. ■ Minimized line disturbances caused by SCR (silicon controlled rectifiers) firing. ■ Reduced short circuit currents and voltage line transients. Drive isolation transformers are specifically sized to the drive kVA requirements and are braced to withstand the mechanical stresses of current reversals and short circuits associated with SCR drives. ■ UL listed. 60 Hz operation (50/60 Hz operation available). Short-term overload capability as required by ANSI. Primary and secondary terminals are front accessible for fast and easy connection. Slotted screw mounting holes in enclosure and cover reduce installation time. Sound dampening pads, which isolate the core and coil from the case, reduce noise levels to meet NEMA ST-20. Core laminations of precision sheared grain oriented silicon steel are hand stacked to insure quiet operation. Terminations are clearly marked for easy identification. Three-phase transformers have one 5% full capacity tap above and below nominal voltage for incoming source adjustment. Units are suitable for continuous operation in a 40°C ambient maximum. Full current neutral. Thermoguard protection embedded in coils to indicate that high temperatures (approximately 190°C) are present. Three coil delta-wye configurations are used throughout the product line. Standards and Certifications ■ ANSI C89.2 ■ NEMA ST-20 ■ UL 506 ■ UL 1561 Seismic Qualified All Cutler-Hammer manufactured drytype distribution transformers by Eaton Corporation are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. For more information visit: www.cutler-hammer.eaton.com ■ ■ ■ ■ ■ ■ Copper windings. Non-standard voltages. 50/60 Hz designs. Delta-delta configuration. 80°C or 115°C rise designs. Totally enclosed non-ventilated. Electrostatic shields. Please refer to Page 9-120. Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-55. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. CA08101001E Transformers Drive Isolation Transformers 9-51 November 2003 Three-Phase Vol. 1, Ref. No. [0351] Enclosures Sound Levels Winding Terminations Eaton’s Cutler-Hammer ventilated transformers, Type MD, utilize a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Primary and secondary windings are terminated in the wiring compartment. Ventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 75°C for ventilated designs. Table 9-56. Average Sound Levels Technical Data and Specifications Please refer to Page 9-122. NEMA ST-20 Average Sound Level (dB) kVA CA08101001E Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 For more information visit: www.cutler-hammer.eaton.com 9 Transformers Drive Isolation Transformers 9-52 November 2003 Three-Phase Vol. 1, Ref. No. [0352] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-57. Drive Isolation Transformers Hp kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Lbs. Dimensions (mm) Wt. kg H W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ FR909 FR909 FR909 286L 286L 286L WS31 WS31 WS31 350. MD075E85 350. MD11E85 350. MD14E85 1,400. 1,450. 1,550. Price U.S. $ 208 ∆ Volts to 230Y/133 Volts 9 5 7.5 10 7.5 11 14 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 25 25 25 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 152 152 635 635 635 511 511 511 358 358 358 69 69 69 15 20 25 20 27 34 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 230 310 765 765 765 511 511 511 358 358 358 104 104 140 FR910A FR910A FR912A 286L 286L 286L WS31 WS31 WS31 350. MD20E85 350. MD27E85 350. MD34E85 1,920. 2,195. 2,430. 30 40 50 40 51 63 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 310 480 480 765 1000 1000 511 663 663 358 485 485 140 217 217 FR912A FR914B FR914B 286L 286L 286L WS31 WS33 WS33 350. MD40E85 350. MD51E85 350. MD63E85 2,800. 3,165. 3,580. 60 75 100 75 93 118 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 712 485 485 585 217 272 344 FR914B FR915B FR916A 286L 286L 286L WS33 WS33 WS19 350. MD75E85 350. MD93E85 350. MD118E85 3,875. 4,650. 5,440. 125 150 200 145 175 220 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 46-1/8 56 56 28 31-1/4 31-1/4 23 24-1/4 24-1/4 760 1100 1200 1171 1422 1422 712 793 793 585 616 616 344 499 499 FR916A FR917 FR917 286L 286L 286L WS19 WS34 WS34 350. MD145E85 800. MD175E85 800. MD220E85 6,350. 8,030. 9,300. 250 300 275 330 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 150 150 62-1/4 75 31-1/4 44-1/2 30-1/4 36 1600 2200 1581 1905 794 1130 768 914 728 1000 FR918A FR919 286L WS34 WS35 800. MD275E85 1,360. MD330E85 10,880. 12,925. FR909 FR909 FR909 286L 286L 286L WS31 WS31 WS31 350. MD075E86 350. MD11E86 350. MD14E86 1,400. 1,450. 1,550. 208 ∆ Volts to 460Y/266 Volts 5 7.5 10 7.5 11 14 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 25 25 25 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 152 152 635 635 635 511 511 511 358 358 358 69 69 69 15 20 25 20 27 34 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 230 310 765 765 765 511 511 511 358 358 358 104 104 140 FR910A FR910A FR912A 286L 286L 286L WS31 WS31 WS31 350. MD20E86 350. MD27E86 350. MD34E86 1,920. 2,195. 2,430. 30 40 50 40 51 63 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 310 480 480 765 1000 1000 511 663 663 358 485 485 140 217 217 FR912A FR914B FR914B 286L 286L 286L WS31 WS33 WS33 350. MD40E86 350. MD51E86 350. MD63E86 2,800. 3,165. 3,580. 60 75 100 75 93 118 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 712 485 485 585 217 272 344 FR914B FR915B FR916A 286L 286L 286L WS33 WS33 WS19 350. MD75E86 350. MD93E86 350. MD118E86 3,875. 4,650. 5,440. 125 150 200 145 175 220 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 46-1/8 56 56 28 31-1/4 31-1/4 23 24-1/4 24-1/4 760 1100 1200 1171 1422 1422 712 793 793 585 616 616 344 499 499 FR916A FR917 FR917 286L 286L 286L WS19 WS34 WS34 350. MD145E86 800. MD175E86 800. MD220E86 6,350. 8,030. 9,300. 250 300 275 330 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 150 150 62-1/4 75 31-1/4 44-1/2 30-1/4 36 1600 2200 1581 1905 794 1130 768 914 728 1000 FR918A FR919 286L WS34 WS35 800. MD275E86 1,360. MD330E86 10,880. 12,925. FR909 FR909 FR909 286A 286A 286A WS31 WS31 WS31 350. MD075E88 350. MD11E88 350. MD14E88 1,400. 1,450. 1,550. 230 ∆ Volts to 230Y/133 Volts 5 7.5 10 7.5 11 14 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 25 25 25 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 152 152 635 635 635 511 511 511 358 358 358 69 69 69 15 20 25 20 27 34 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 230 310 765 765 765 511 511 511 358 358 358 104 104 140 FR910A FR910A FR912A 286A 286A 286A WS31 WS31 WS31 350. MD20E88 350. MD27E88 350. MD34E88 1,920. 2,195. 2,430. 30 40 50 40 51 63 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 310 480 480 765 1000 1000 511 663 663 358 485 485 140 217 217 FR912A FR914B FR914B 286A 286A 286A WS31 WS33 WS33 350. MD40E88 350. MD51E88 350. MD63E88 2,800. 3,165. 3,580. 60 75 100 75 93 118 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 712 485 485 585 217 272 344 FR914B FR915B FR916A 286A 286A 286A WS33 WS33 WS19 350. MD75E88 350. MD93E88 350. MD118E88 3,875. 4,650. 5,440. 125 150 200 145 175 220 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 46-1/8 56 56 28 31-1/4 31-1/4 23 24-1/4 24-1/4 760 1100 1200 1171 1422 1422 712 793 793 585 616 616 344 499 499 FR916A FR917 FR917 286A 286A 286A WS19 WS34 WS34 350. MD145E88 800. MD175E88 800. MD220E88 6,350. 8,030. 9,300. 250 300 400 275 330 440 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 31-1/4 44-1/2 30-1/4 36 1600 2200 1581 1905 794 1130 768 914 728 1000 FR918A FR919 286A WS34 WS35 800. MD275E88 1,360. MD330E88 — MD440E88 10,880. 12,925. 18,900. 500 600 700 800 550 660 770 880 1@+5% 1@+5% 1@+5% 1@+5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 MD550E88 MD660E88 MD770E88 MD880E88 22,800. 27,600. 34,400. 39,300. 1@-5% 1@-5% 1@-5% 1@-5% — — — — Refer to your Cutler-Hammer sales office. Not Seismic Qualified. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Drive Isolation Transformers 9-53 November 2003 Three-Phase Vol. 1, Ref. No. [0353] Table 9-58. Drive Isolation Transformers Hp kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Lbs. Dimensions (mm) Wt. kg H W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 230 ∆ Volts to 460Y/266 Volts 5 7.5 10 15 7.5 11 14 20 1@+5% 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 25 25 25 30-1/8 20-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 14-1/8 152 152 152 230 635 635 635 765 511 511 511 511 358 358 358 358 69 69 69 104 FR909 FR909 FR909 FR910A 286A 286A 286A 286A WS31 WS31 WS31 WS31 350. 350. 350. 350. 20 25 30 27 34 40 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 310 310 765 765 765 511 511 511 358 358 358 104 140 140 FR910A FR912A FR912A 286A 286A 286A WS31 WS31 WS31 350. MD27E89 350. MD34E89 350. MD40E89 2,195. 2,430. 2,800. 40 50 60 51 63 75 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 39-3/8 26-1/8 26-1/8 26-1/8 19-1/8 19-1/8 19-1/8 480 480 480 1000 1000 1000 663 663 663 485 485 485 217 217 217 FR914B FR914B FR914B 286A 286A 286A WS33 WS33 WS33 350. MD51E89 350. MD63E89 350. MD75E89 3,165. 3,580. 3,875. 75 100 125 93 118 145 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 46-1/8 26-1/8 28 28 19-1/8 23 23 600 760 760 1000 1171 1171 663 712 712 485 585 585 272 344 344 FR915B FR916A FR916A 286A 286A 286A WS33 WS33 WS19 350. MD93E89 350. MD118E89 350. MD145E89 4,650. 5,440. 6,350. 150 200 250 175 220 275 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 56 56 62-1/4 31-1/4 31-1/4 31-1/4 24-1/4 24-1/4 30-1/4 1100 1200 1600 1422 1422 1581 793 793 794 616 616 768 499 499 728 FR917 FR917 FR918A 286A 286A 286A WS34 WS34 WS34 800. MD175E89 800. MD220E89 800. MD275E89 8,030. 9,300. 10,880. 300 400 500 330 440 550 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 75 44-1/2 36 2200 1905 1130 914 1000 FR919 321A WS35 1,360. MD330E89 — MD440E89 — MD550E89 12,925. 18,900. 22,800. 600 700 800 660 770 880 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 — MD660E89 — MD770E89 — MD880E89 27,600. 34,400. 39,300. FR909 FR909 FR909 286A 286A 286A WS31 WS31 WS31 350. MD075E90 350. MD11E90 350. MD14E90 1,400. 1,450. 1,550. MD075E89 MD11E89 MD14E89 MD20E89 1,400. 1,450. 1,550. 1,920. 230 ∆ Volts to 575Y/332 Volts 5 7.5 10 7.5 1@+5% 11 1@+5% 14 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 25 25 25 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 152 152 635 635 635 511 511 511 358 358 358 69 69 69 15 20 25 20 27 34 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 230 310 765 765 765 511 511 511 358 358 358 104 104 140 FR910A FR910A FR912A 286A 286A 286A WS31 WS31 WS31 350. MD20E90 350. MD27E90 350. MD34E90 1,920. 2,195. 2,430. 30 40 50 40 51 63 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 310 480 480 765 1000 1000 511 663 663 358 485 485 140 217 217 FR912A FR914B FR914B 286A 286A 286A WS31 WS33 WS33 350. MD40E90 350. MD51E90 350. MD63E90 2,800. 3,165. 3,580. 60 75 100 75 93 118 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 712 485 485 585 217 272 344 FR914B FR915B FR916A 286A 286A 286A WS33 WS33 WS19 350. MD75E90 350. MD93E90 350. MD118E90 3,875. 4,650. 5,440. 125 150 200 145 175 220 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 46-1/8 56 56 28 31-1/4 31-1/4 23 24-1/4 24-1/4 760 1100 1200 1171 1422 1422 712 793 793 585 616 616 344 499 499 FR916A FR917 FR917 286A 286A 286A WS19 WS34 WS34 350. MD145E90 800. MD175E90 800. MD220E90 6,350. 8,030. 9,300. 250 300 400 275 330 440 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 31-1/4 44-1/2 30-1/4 36 1600 2200 1581 1905 794 1130 768 914 728 1000 FR918A FR919 286A WS34 WS35 800. MD275E90 1,360. MD330E90 — MD440E90 10,880. 12,925. 18,900. 500 600 700 550 660 770 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 — MD550E90 — MD660E90 — MD770E90 22,800. 27,600. 34,400. Refer to your Cutler-Hammer sales office. Not Seismic Qualified. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Drive Isolation Transformers 9-54 November 2003 Three-Phase Vol. 1, Ref. No. [0354] Table 9-59. Drive Isolation Transformers Hp kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Wt. Temp. H Lbs. W D Rise Dimensions (mm) H W D Wt. kg Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 460 ∆ Volts to 230Y/133 Volts 9 5 7.5 10 15 7.5 11 14 20 1@+5% 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 25 25 25 30-1/8 20-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 14-1/8 152 152 152 230 635 635 635 765 511 511 511 511 358 358 358 358 69 69 69 104 FR909 FR909 FR909 FR910A 286D 286D 286D 286D WS31 WS31 WS31 WS31 350. 350. 350. 350. 20 25 30 27 34 40 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 310 310 765 765 765 511 511 511 358 358 358 104 140 140 FR910A FR912A FR912A 286D 286D 286D WS31 WS31 WS31 350. MD27E91 350. MD34E91 350. MD40E91 2,195. 2,430. 2,800. 40 50 60 51 63 75 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 39-3/8 26-1/8 26-1/8 26-1/8 19-1/8 19-1/8 19-1/8 480 480 480 1000 1000 1000 663 663 663 485 485 485 217 217 217 FR914B FR914B FR914B 286D 286D 286D WS33 WS33 WS33 350. MD51E91 350. MD63E91 350. MD75E91 3,165. 3,580. 3,875. 75 100 125 93 118 145 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 46-1/8 26-1/8 28 28 19-1/8 23 23 600 760 760 1000 1171 1171 663 712 712 485 585 585 272 344 344 FR915B FR916A FR916A 286D 286D 286D WS33 WS19 WS19 350. MD93E91 350. MD118E91 350. MD145E91 4,650. 5,440. 6,350. 150 200 250 175 220 275 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 56 56 62-1/4 31-1/4 31-1/4 31-1/4 24-1/4 24-1/4 30-1/4 1100 1200 1600 1422 1422 1581 793 793 794 616 616 768 499 499 728 FR917 FR917 FR918A 286D 286D 286D WS34 WS34 WS34 800. MD175E91 800. MD220E91 800. MD275E91 8,030. 9,300. 10,880. 300 400 500 330 440 550 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 75 75 75 44-1/2 44-1/2 44-1/2 36 36 36 2200 2200 2900 1905 1905 1905 1130 1130 1130 914 914 914 1000 1000 1315 FR919 FR919 FR920 318E 318E 318E WS35 WS35 WS35 1,360. MD330E91 1,360. MD440E91 1,360. MD550E91 12,925. 18,900. 22,800. 600 700 800 660 770 880 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 75 75 44-1/2 44-1/2 36 36 2900 2900 1905 1905 1130 1130 914 914 1315 1315 FR920 FR920 318E 318E WS35 WS35 1,360. MD660E91 1,360. MD770E91 — MD880E91 27,600. 34,400. 39,300. 1000 1250 1500 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 — — — MD075E91 MD11E91 MD14E91 MD20E91 — MD1000E91 — MD1250E91 — MD1500E91 1,400. 1,450. 1,550. 1,920. 42,570. 49,500. 78,600. 460 ∆ Volts to 460Y/266 Volts 5 7.5 10 15 7.5 11 14 20 1@+5% 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 25 25 25 30-1/8 20-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 14-1/8 152 152 152 230 635 635 635 765 511 511 511 511 358 358 358 358 69 69 69 104 FR909 FR909 FR909 FR910A 286D 286D 286D 286D WS31 WS31 WS31 WS31 350. 350. 350. 350. 20 25 30 27 34 40 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 310 310 765 765 765 511 511 511 358 358 358 104 140 140 FR910A FR912A FR912A 286D 286D 286D WS31 WS31 WS31 350. MD27E92 350. MD34E92 350. MD40E92 2,195. 2,430. 2,800. 40 50 60 51 63 75 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 39-3/8 26-1/8 26-1/8 26-1/8 19-1/8 19-1/8 19-1/8 480 480 480 1000 1000 1000 663 663 663 485 485 485 217 217 217 FR914B FR914B FR914B 286D 286D 286D WS33 WS33 WS33 350. MD51E92 350. MD63E92 350. MD75E92 3,165. 3,580. 3,875. 75 100 125 93 118 145 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 46-1/8 26-1/8 28 28 19-1/8 23 23 600 760 760 1000 1171 1171 663 712 712 485 585 585 272 344 344 FR915B FR916A FR916A 286D 286D 286D WS33 WS19 WS19 350. MD93E92 350. MD118E92 350. MD145E92 4,650. 5,440. 6,350. 150 200 250 175 220 275 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 56 56 62-1/4 31-1/4 31-1/4 31-1/4 24-1/4 24-1/4 30-1/4 1100 1200 1600 1422 1422 1581 793 793 794 616 616 768 499 499 728 FR917 FR917 FR918A 286D 286D 286D WS34 WS34 WS34 800. MD175E92 800. MD220E92 800. MD275E92 8,030. 9,300. 10,880. 300 400 500 330 440 550 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 75 75 75 44-1/2 44-1/2 44-1/2 36 36 36 2200 2200 2900 1905 1905 1905 1130 1130 1130 914 914 914 1000 1000 1315 FR919 FR919 FR919 318E 318E 318E WS35 WS35 WS35 1,360. MD330E92 1,360. MD440E92 1,360. MD550E92 12,925. 18,900. 22,800. 600 700 800 660 770 880 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 75 75 44-1/2 44-1/2 36 36 2900 2900 1905 1905 1130 1130 914 914 1315 1315 FR920 FR920 318E 318E WS35 WS35 1,360. MD660E92 1,360. MD770E92 — MD880E92 27,600. 34,400. 39,300. 1000 1250 1500 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 150 150 150 — — — MD075E92 MD11E92 MD14E92 MD20E92 — MD1000E92 — MD1250E92 — MD1500E92 1,400. 1,450. 1,550. 1,920. 42,570. 49,500. 78,600. Refer to your Cutler-Hammer sales office. Not Seismic Qualified. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Drive Isolation Transformers 9-55 November 2003 Three-Phase Vol. 1, Ref. No. [0355] Table 9-60. Drive Isolation Transformers Hp kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Wt. Temp. H Lbs. W D Rise Dimensions (mm) H W D Wt. kg Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ FR909 FR909 FR909 286D 286D 286D WS31 WS31 WS31 350. MD075E93 350. MD11E93 350. MD14E93 1,400. 1,450. 1,550. Price U.S. $ 460 ∆ Volts to 575Y/332 Volts 5 7.5 10 7.5 1@+5% 1@-5% 11 1@+5% 1@-5% 14 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 25 25 25 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 152 152 635 635 635 511 511 511 358 358 358 69 69 69 15 20 25 20 27 34 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 230 310 765 765 765 511 511 511 358 358 358 104 104 140 FR910A FR910A FR912A 286D 286D 286D WS31 WS31 WS31 350. MD20E93 350. MD27E93 350. MD34E93 1,920. 2,195. 2,430. 30 40 50 40 51 63 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 310 480 480 765 1000 1000 511 663 663 358 485 485 140 217 217 FR912A FR914B FR914B 286D 286D 286D WS31 WS33 WS33 350. MD40E93 350. MD51E93 350. MD63E93 2,800. 3,165. 3,580. 60 75 100 75 93 118 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 20-1/8 480 600 760 1000 1000 1171 663 663 712 485 485 585 217 272 344 FR914B FR915B FR916A 286D 286D 286D WS33 WS33 WS19 350. MD75E93 350. MD93E93 350. MD118E93 3,875. 4,650. 5,440. 125 150 200 145 175 220 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 46-1/8 56 56 28 31-1/4 31-1/4 23 24-1/4 24-1/4 760 1100 1200 1171 1422 1422 712 793 793 585 616 616 344 499 499 FR916A FR917 FR917 286D 286D 286D WS19 WS34 WS34 350. MD145E93 800. MD175E93 800. MD220E93 6,350. 8,030. 9,300. 250 300 400 275 330 440 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2200 2200 1581 1905 1905 794 1130 1130 768 914 914 728 1000 1000 FR918A FR919 FR919 286D 318E 318E WS34 WS35 WS35 800. MD275E93 1,360. MD330E93 1,360. MD440E93 10,880. 12,925. 18,900. 500 600 700 550 660 770 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 75 75 75 44-1/2 44-1/2 44-1/2 36 36 36 2900 2900 2900 1905 1905 1905 1130 1130 1130 914 914 914 1315 1315 1315 FR920 FR920 FR920 318E 318E 318E WS35 WS35 WS35 1,360. MD550E93 1,360. MD660E93 1,360. MD770E93 22,800. 27,600. 34,400. 575 ∆ Volts to 230Y/133 Volts 5 7.5 10 15 7.5 11 14 20 1@+5% 1@+5% 1@+5% 1@+5% 1@-5% 1@-5% 1@-5% 1@-5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 25 25 25 30-1/8 20-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 14-1/8 152 152 152 230 635 635 635 765 511 511 511 511 358 358 358 358 69 69 69 104 FR909 FR909 FR909 FR910A 286H 286H 286H 286H WS31 WS31 WS31 WS31 350. 350. 350. 350. 20 25 30 27 34 40 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 310 310 765 765 765 511 511 511 358 358 358 104 140 140 FR910A FR912A FR912A 286H 286H 286H WS31 WS31 WS31 350. MD27E94 350. MD34E94 350. MD40E94 2,195. 2,430. 2,800. 40 50 60 51 63 75 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 39-3/8 26-1/8 26-1/8 26-1/8 19-1/8 19-1/8 19-1/8 480 480 480 1000 1000 1000 663 663 663 485 485 485 217 217 217 FR914B FR914B FR914B 286H 286H 286H WS33 WS33 WS33 350. MD51E94 350. MD63E94 350. MD75E94 3,165. 3,580. 3,875. 75 100 125 93 118 145 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 39-3/8 46-1/8 46-1/8 26-1/8 28 28 19-1/8 23 23 600 760 760 1000 1171 1171 663 712 712 485 585 585 272 344 344 FR915B FR916A FR916A 286H 286H 286H WS33 WS19 WS19 350. MD93E94 350. MD118E94 350. MD145E94 4,650. 5,440. 6,350. 150 200 250 175 220 275 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 56 56 62-1/4 31-1/4 31-1/4 31-1/4 24-1/4 24-1/4 30-1/4 1100 1200 1600 1422 1422 1581 793 793 794 616 616 768 499 499 728 FR917 FR917 FR918A 286H 286H 286H WS19 WS34 WS34 350. MD175E94 800. MD220E94 800. MD275E94 8,030. 9,300. 10,880. 300 400 500 330 440 550 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 75 75 75 44-1/2 44-1/2 44-1/2 36 36 36 2200 2200 2900 1905 1905 1905 1130 1130 1130 914 914 914 1000 1000 1315 FR919 FR919 FR920 WS35 WS35 WS35 1,360. MD330E94 1,360. MD440E94 1,360. MD550E94 12,925. 18,900. 22,800. 600 700 800 660 770 880 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 75 75 44-1/2 44-1/2 36 36 2900 2900 1905 1905 1130 1130 914 914 1315 1315 FR920 FR920 WS35 WS35 1,360. MD660E94 1,360. MD770E94 — MD880E94 27,600. 34,400. 39,300. 1000 1250 1500 1@+5% 1@-5% 1@+5% 1@-5% 1@+5% 1@-5% DT-3 DT-3 DT-3 150 150 150 — — — MD075E94 MD11E94 MD14E94 MD20E94 — MD1000E94 — MD1250E94 — MD1500E94 1,400. 1,450. 1,550. 1,920. 42,570. 49,500. 78,600. Refer to your Cutler-Hammer sales office. Not Seismic Qualified. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Drive Isolation Transformers 9-56 November 2003 Three-Phase Vol. 1, Ref. No. [0356] Table 9-61. Drive Isolation Transformers Hp kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Temp. H W D Rise Wt. Lbs. Dimensions (mm) Wt. kg H W D Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 575 ∆ Volts to 460Y/266 Volts 9 5 7.5 10 15 7.5 11 14 20 1@+5% 1@+5% 1@+5% 1@+5% DT-3 DT-3 DT-3 DT-3 150 150 150 150 25 25 25 30-1/8 20-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 14-1/8 152 152 152 230 635 635 635 765 511 511 511 511 358 358 358 358 69 69 69 104 FR909 FR909 FR909 FR910A 286H 286H 286H 286H WS31 WS31 WS31 WS31 350. 350. 350. 350. 20 25 30 27 34 40 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 310 310 765 765 765 511 511 511 358 358 358 104 140 140 FR910A FR912A FR912A 286H 286H 286H WS31 WS31 WS31 350. MD27E95 350. MD34E95 350. MD40E95 2,195. 2,430. 2,800. 40 50 60 51 63 75 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 39-3/8 39-3/8 39-3/8 26-1/8 26-1/8 26-1/8 19-1/8 19-1/8 19-1/8 480 480 480 1000 1000 1000 663 663 663 485 485 485 217 217 217 FR914B FR914B FR914B 286H 286H 286H WS33 WS33 WS33 350. MD51E95 350. MD63E95 350. MD75E95 3,165. 3,580. 3,875. 75 100 125 93 118 145 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 39-3/8 46-1/8 46-1/8 26-1/8 28 28 19-1/8 23 23 600 760 760 1000 1171 1171 663 712 712 485 585 585 272 344 344 FR915B FR916A FR916A 286H 286H 286H WS33 WS19 WS19 350. MD93E95 350. MD118E95 350. MD145E95 4,650. 5,440. 6,350. 150 200 250 175 220 275 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 56 56 62-1/4 31-1/4 31-1/4 31-1/4 24-1/4 24-1/4 30-1/4 1100 1200 1600 1422 1422 1581 793 793 794 616 616 768 499 499 728 FR917 FR917 FR918A 286H 286H 286H WS34 WS34 WS34 800. MD175E95 800. MD220E95 800. MD275E95 8,030. 9,300. 10,880. 300 400 500 330 440 550 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 75 75 75 44 44 44 36 36 36 2200 2200 2900 1905 1905 1905 1130 1130 1130 914 914 914 1000 1000 1315 FR919 FR919 FR920 318F 318F 318F WS35 WS35 WS35 1,360. MD330E95 1,360. MD440E95 1,360. MD550E95 12,925. 18,900. 22,800. 600 700 800 660 770 880 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 75 75 44-1/2 44-1/2 36 36 2900 2900 1905 1905 1130 1130 914 914 1315 1315 FR920 FR920 318F 318F WS35 WS35 1,360. MD660E95 1,360. MD770E95 — MD880E95 27,600. 34,400. 39,300. 1000 1250 1500 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 FR909 FR909 FR909 286H 286H 286H WS31 WS31 WS31 350. MD075E96 350. MD11E96 350. MD14E96 1,400. 1,450. 1,550. — — — 1@-5% 1@-5% 1@-5% 1@-5% MD075E95 MD11E95 MD14E95 MD20E95 — MD1000E95 — MD1250E95 — MD1500E95 1,400. 1,450. 1,550. 1,920. 42,570. 49,500. 78,600. 575 ∆ Volts to 575Y/332 Volts 5 7.5 10 7.5 1@+5% 1@-5% DT-3 11 1@+5% 1@-5% DT-3 14 1@+5% 1@-5% DT-3 150 150 150 25 25 25 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 152 152 152 635 635 635 511 511 511 358 358 358 69 69 69 15 20 25 20 27 34 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 230 310 765 765 765 511 511 511 358 358 358 104 104 140 FR910A FR910A FR912A 286H 286H 286H WS31 WS31 WS31 350. MD20E96 350. MD27E96 350. MD34E96 1,920. 2,195. 2,430. 30 40 50 40 51 63 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 30-1/8 39-3/8 39-3/8 20-1/8 26-1/8 26-1/8 14-1/8 19-1/8 19-1/8 310 480 480 765 1000 1000 511 663 663 358 485 485 140 217 217 FR912A FR914B FR914B 286H 286H 286H WS31 WS33 WS33 350. MD40E96 350. MD51E96 350. MD63E96 2,800. 3,165. 3,580. 60 75 100 75 93 118 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 1000 1000 1171 663 663 712 485 485 585 217 272 344 FR914B FR915B FR916A 286H 286H 286H WS33 WS33 WS19 350. MD75E96 350. MD93E96 350. MD118E96 3,875. 4,650. 5,440. 125 150 200 145 175 220 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 46-1/8 56 56 28 31-1/4 31-1/4 23 24-1/4 24-1/4 760 1100 1200 1171 1422 1422 712 793 793 585 616 616 344 499 499 FR916A FR917 FR917 286H 286H 286H WS19 WS34 WS34 350. MD145E96 800. MD175E96 800. MD220E96 6,350. 8,030. 9,300. 250 300 400 275 330 440 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 62-1/4 75 75 31-1/4 44-1/2 44-1/2 30-1/4 36 36 1600 2200 2200 1581 1905 1905 794 1130 1130 768 914 914 728 1000 1000 FR918A FR919 FR919 286H WS34 WS35 WS35 800. MD275E96 1,360. MD330E96 1,360. MD440E96 10,880. 12,925. 18,900. 500 600 700 550 660 770 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 1@+5% 1@-5% DT-3 150 150 150 75 75 44-1/4 44-1/4 36 36 2900 2900 1905 1905 1130 1130 914 914 1315 1315 FR920 FR920 WS35 WS35 1,360. MD550E96 1,360. MD660E96 — MD770E96 22,800. 27,600. 34,400. Refer to your Cutler-Hammer sales office. Not Seismic Qualified. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Mini-Power Centers 9-57 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0357] Mini-Power Centers ■ ■ ■ ■ ■ ■ ■ ■ Three-Phase Mini-Power Center Product Description ■ Sand and Resin Encapsulated design. ■ Suitable for indoor or outdoor applications. ■ 185°C Insulation system, 115°C Rise standard. Application Description A Mini-Power Center combines three individual components into one NEMA Type 3R enclosure: a main breaker, an encapsulated single-phase (Type EP) or three-phase (EPT) Dry-Type Transformer, and a secondary distribution loadcenter with main breaker. Interconnecting wiring is completed at the factory. Mini-Power Centers are used wherever there is a 480 volt or 600 volt distribution system and loads requiring 208Y/120 volt, 3-phase or 120/240 volt single-phase. Typical installations include: ■ ■ ■ ■ ■ ■ ■ ■ ■ Industrial plant assembly lines. Plant expansions. Test equipment. Temporary construction site power. Sewage disposal plants. Warehouses. Car washes. Parking lots. Commercial buildings. Features, Benefits and Functions ■ UL listed, CSA certified. 60 Hz operation. ■ Indoor-Outdoor, NEMA 3R. ■ Primary main breaker. ■ Secondary main breaker (Type BR feeder breakers not included). ■ ■ ■ All live parts enclosed for personnel safety. Cover is hinged to prevent removal and can be padlocked. Cores are grounded with a copper lead. Ground bar is supplied to permit grounding of individual secondary circuits. Neutral bar is grounded to case. Feeder circuits can be easily added or changed using Type BR plug-in breakers. Suitable for service entrance. Aluminum windings and loadcenter chassis standard. Short-term overload capability as required by ANSI. Meet NEMA ST-20 sound levels. Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. Options and Accessories Please refer to Page 9-120. being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-62. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Sound Levels All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Winding Terminations Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without The Cutler-Hammer business recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Technical Data and Specifications Please refer to Page 9-122. The following pages provide listings for most standard transformer ratings and styles. For all-copper and bolt-on-breaker designs, contact Eaton’s Cutler-Hammer business. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to the Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Mini-Power Centers 9-58 November 2003 Single-Phase and Three-Phase Vol. 1, Ref. No. [0358] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-63. Single-Phase — Mini-Power Centers kVA Full Cap. Taps FCBN Dimensions (Inches) H W Wt. Dimensions Lbs. (mm) D H W Wt. Frame kg D Wiring Diagram Number Main Circuit Breaker 97A3K 110A5K 109A7K EHD2015 BR215 EHD2020 BR225 EHD2030 BR230 Primary Feeder Max. Style Breakers Amp Number Secondary Max. Number 1-Pole 2-Pole Price U.S. $ 480 Volts to 120/240 Volts 3 2@-5% 27-1/2 12-9/16 5 2@-5% 29-1/2 12-9/16 7.5 2@-5% 29-1/2 12-9/16 10 15 25 2@-5% 38-1/8 13-1/2 2@-5% 38-1/8 13-1/2 2@-5% 43-7/8 16-3/8 9-3/4 105 9-3/4 110 9-3/4 125 11-7/8 180 11-7/8 215 14-5/8 373 698 319 248 749 319 248 749 319 248 47 FR283 50 FR284 56 FR284 968 342 301 82 FR285 968 342 301 98 FR286 1115 417 372 169 FR287 8 12 12 4 6 6 12 20 30 P48G11S03P P48G11S05P P48G11S07P 2,100. 2,940. 3,540. 108A10K EHD2040 BR250 107A15K EHD2060 BR270 106A25K EHD2100 BR2125 12 20 26 6 10 13 40 60 100 P48G11S10P P48G11S15P P48G11S25P 3,720. 5,000. 7,240. 110B5K FDB2015 BR225 109B7K FDB2030 BR230 108B10K FDB2040 BR250 12 12 12 6 6 6 20 30 40 P60G11S05P P60G11S07P P60G11S10P 3,785. 4,040. 4,240. 107B15K FDB2060 BR270 106B25K FDB2100 BR2125 20 26 10 13 60 100 P60G11S15P P60G11S25P 5,640. 8,310. 600 Volts to 120/240 Volts 9 5 2@-5% 29-1/2 12-9/16 9-3/4 110 7.5 2@-5% 29-1/2 12-9/16 9-3/4 125 10 2@-5% 38-1/8 13-1/2 11-7/8 180 15 25 2@-5% 38-1/8 13-1/2 2@-5% 43-7/8 16-3/8 11-7/8 215 14-5/8 373 749 319 248 749 319 248 968 342 301 50 FR284 56 FR284 82 FR285 968 342 301 98 FR286 1115 417 372 169 FR287 Table 9-64. Three-Phase — Mini-Power Centers kVA Full Cap. Taps FCBN Dimensions (Inches) H W Wt. Dimensions Lbs. (mm) W D Wt. Frame kg Max. Style Wiring Main Circuit Breaker Feeder Breakers Amp Number Diagram Number Primary Secondary Max. Number 1-Pole 2-Pole Price U.S. $ D H 9-3/8 320 13-5/8 565 13-5/8 635 917 730 238 145 FR289A 105A15K EHD3040 BR350 1038 759 346 256 FR290A 103A21K EHD3070 BR370 1063 759 346 288 FR291A 104A30K EHD3090 BR3100 18 18 24 6 6 8 40 60 80 P48G28T15P 7,420. P48G28T21P 9,225. P48G28T30P 11,750. 9-3/8 320 13-5/8 565 13-5/8 635 917 730 238 145 FR289A 105D15K FDB3030 BR350 1038 759 346 256 FR290A 103B21K FDB3050 BR370 1063 759 346 288 FR291A 104B30K FDB3070 BR3100 18 18 24 6 6 8 40 60 80 P60G28T15P 8,685. P60G28T21P 10,860. P60G28T30P 15,150. 480 ∆ Volts to 208Y/120 Volts 15 2@-5% 36-1/8 28-3/4 22.5 2@-5% 40-7/8 29-7/8 30 2@-5% 41-7/8 29-7/8 600 ∆ Volts to 208Y/120 Volts 15 2@-5% 36-1/8 28-3/4 22.5 2@-5% 40-7/8 29-7/8 30 2@-5% 41-7/8 29-7/8 Primary breakers with higher interrupting capacity available. For HFD breaker, add suffix “H.” For FD breaker, add suffix “F.” For FDC breaker, add suffix “C.” Main breakers are fixed only. Combinations can be selected. Feeder breakers not included, use Eaton’s Cutler-Hammer Type BR. Note: For 316 grade stainless steel enclosure replace 10th character of catalog number with an “SS” suffix, i.e., P48G11S03SS. Note: For all-copper, bolt-on breaker designs, contact the Cutler-Hammer business. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Totally Enclosed Non-Ventilated Transformers 9-59 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0359] Single- and Three-Phase, Types DS-3E, DT-3E, 60 Hz Features, Benefits and Functions ■ 60 Hz operation (50/60 Hz operation available). ■ Short-term overload capability as required by ANSI. ■ Meet NEMA ST-20 sound levels. Standards and Certifications Industry Standards Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Product Description ■ Suitable for indoor or outdoor applications. ■ Totally enclosed, non-ventilated enclosures. ■ 220°C insulation system, 150°C rise standard. Application Description Totally enclosed non-ventilated drytype transformers are for special applications, where because of adverse atmospheric conditions it is desirable to use a dry-type non-ventilated transformer vs. the ventilated standard unit, which has openings in its enclosure to allow air to flow directly over the core and coil. In applications where the atmosphere contains conductive, corrosive, or combustible materials, which might damage a transformer, or lint and dust flyings which might block the ventilation passages, the non-ventilated transformer is highly suited. It has no openings in the enclosure. Heat is dissipated by radiating from the surface area of the enclosure. Consequently, the enclosures are larger than those of the standard ventilated type. Non-ventilated transformers are suited for application in the textile, chemical, automotive, petrochemical, foundry, cement, food, paper, and other industries where the transformer is subject to spray or washdown conditions. All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. Seismically Qualified Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. Options and Accessories Please refer to Page 9-120. Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-65. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Cutler-Hammer totally enclosed, nonventilated transformers, Types DS-3E and DT-3E, utilize a NEMA 3R rated enclosure as standard. Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Totally enclosed non-ventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 75°C for ventilated designs. Series-Multiple Windings Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications Please refer to Page 9-122. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Totally Enclosed Non-Ventilated Transformers 9-60 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0360] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-66. Single-Phase Selection Information — Type DS-3E, 60 Hz kVA Type °C Temp. Rise Dimensions (Inches) H W Weight Lbs. D Dimensions (mm) H W D Weight kg Frame Wiring Diagram Number Style Number FR820N FR820N 3XA 3XA T20P11S37NV T20P11S50NV Frame Wiring Diagram Number Style Number Price U.S. $ 240 x 480 Volts to 120/240 Volts +1 – 5%, -2 – 5% at 240 Volts Primary; +2 – 2.5%, -4 – 2.5% at 480 Volts primary. 37.5 50 DS-3E DS-3E 150 150 42-1/8 42-1/8 24 24 23-3/8 23-3/8 600 720 1070 1070 610 610 594 594 274 329 4,330. 5,400. Table 9-67. Three-Phase Selection Information — Type DT-3E, 60 Hz kVA Type °C Temp. Rise Dimensions (Inches) H W Weight Lbs. D Dimensions (mm) H W D Weight kg Price U.S. $ 480 ∆ Volts to 208Y/120 Volts +2 – 2.5% FCAN, 4 – 2.5% FCBN Taps 30 45 75 DT-3E DT-3E DT-3E 150 150 150 39-1/4 39-1/4 46-1/2 26-1/8 26-1/8 28 19-1/8 19-1/8 23 480 600 760 995 995 1171 663 663 712 486 486 585 217 272 344 112.5 150 225 300 DT-3E DT-3E DT-3E DT-3E 150 150 150 150 56 56 75 75 31-1/4 31-1/4 44-1/2 44-1/2 24-1/2 24-1/2 36 36 1100 1300 2400 2900 1422 1422 1905 1905 793 793 1130 1130 622 622 914 914 499 589 1088 1315 9 FR914AN 280B FR915AN 280B FR916AN 280B V48M28T30NV V48M28T45NV V48M28T75NV 3,080. 4,400. 5,500. FR917N FR918AN FR919N FR920N V48M28T12NV V48M28T49NV V48M28T22NV V48M28T33NV 8,000. 10,100. 16,000. 26,000. 280B 280B 275A 275A Types DS-3 and DT-3 non-ventilated transformers are not UL listed. Transformers Type EPT 75 kVA and smaller three-phase, and Type EP 25 kVA and smaller single-phase, are furnished non-ventilated normally, as standard (and are UL listed). See General Purpose Transformers. Note: Contact your local Cutler-Hammer sales office for availability of additional Totally Enclosed Non-Ventilated Transformers. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Class I, Division 2, Groups C and D Transformers 9-61 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0361] Single- and Three-Phase, Types EPZ, EPTZ, 60 Hz 8. Or, a location that is adjacent to a Class I, Division 1 location and ignitable concentrations of gases or vapors might occasionally enter. Atmospheres classified by NEC Section 500 as Group C may contain gases or vapors such as ethyl ether, ethylene, or the equivalent. Atmospheres classified as Group D may contain gases or vapors such as acetone, ammonia, benzene, butane, cyclopropane, ethanol, gasoline, hexane, methanol, methane, natural gas, naphtha, propane, or the equivalent. Single-Phase Type EPZ Encapsulated Product Description ■ ■ ■ ■ ■ ■ Sand and Resin Encapsulated design. Suitable for indoor or outdoor applications. Totally enclosed, non-ventilated enclosures. 185°C Insulation system, 115°C Rise standard. Mountable in any position indoors. Upright only outdoors. Available in ratings up to 600 volts primary, 37.5 kVA single-phase, 75 kVA three-phase. Application Description Type EPZ and EPTZ transformers are labeled as “Suitable for use in Class I, Division 2, Groups C and D locations, as defined by NEC Article 501, with NEC-recommended installation procedures for dry-type transformers rated under 600 volts nominal operation.” A Class I, Division 2 location per Section 500 of the NEC is defined as: 6. A location in which volatile flammable liquids or gases are handled, processed or used, but which normally will be confined within closed containers or systems from which they can escape only in case of accidental rupture or breakdown of the container or system. 7. Or, a location where ignitable concentrations of gases or vapors are normally prevented by positive mechanical ventilation and which might become hazardous through failure of the ventilation equipment. CA08101001E Features, Benefits and Functions ■ ■ ■ ■ ■ ■ NEMA 3R enclosure. 60 Hz operation. Aluminum windings (copper optional). Short-term overload capability as required by ANSI. Meet NEMA ST-20 sound levels. Long leads to ease wiring to junction box. Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. Seismically Qualified Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. Options and Accessories Please refer to Page 9-120. Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. For more information visit: www.cutler-hammer.eaton.com Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-68. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Cutler-Hammer encapsulated transformers, Types EPZ and EPTZ, utilize a NEMA 3R rated enclosure. Sound Levels All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. 9 Transformers Class I, Division 2, Groups C and D Transformers 9-62 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0362] Winding Terminations Series-Multiple Windings Lugs are not supplied with these transformers. Eaton’s Cutler-Hammer business recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an Nominal and tap leads come out of the transformer through pipe elbows. Connections should be made to an adjacent explosion-proof junction box. Unused tap leads must be properly insulated prior to energization. EPZ and EPTZ transformers are not UL listed. example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications Please refer to Page 9-122. Product Selection 9 Additional Product Selection information begins on Page 9-136. Table 9-69. Single-Phase Selection Information — Type EPZ, 60 Hz kVA Full Cap. Taps FCAN Type °C Dimensions (Inches) Temp. H W D Rise FCBN Wt. Lbs. Dimensions (mm) Wt. kg H W D Frame Wiring Style Diagram Number Number Price U.S. $ 480 Volts to 120/240 Volts .05 .75 1 — — — — — — EPZ EPZ EPZ 115 115 115 6-1/2 8-3/8 8-3/8 4-7/8 6 6 4-5/8 5-3/4 5-3/4 13 21 31 165 213 213 124 152 152 118 146 146 6 10 14 FR57H 524H FR58AH 524H FR59AH 524H Z48N11S51A Z48N11S76A Z48N11S01A 510. 675. 805. 1.5 2 3 — — — — — — EPZ EPZ EPZ 115 115 115 10-3/4 10-3/4 14-1/8 6-3/16 6-3/16 7-3/4 6-1/8 6-1/8 8 40 40 65 273 273 359 157 157 197 156 156 203 18 18 30 FR67H FR68H FR176H 524H 524H 524H Z48N11S16A Z48N11S02A Z48N11S03A 975. 1,185. 1,370. 5 7.5 10 — — — — — — EPZ EPZ EPZ 115 115 115 16 16 19 10-3/8 10-3/8 13-3/8 9-7/8 9-7/8 10-1/2 113 123 193 406 406 483 264 264 340 232 232 267 51 56 88 FR177H FR178H FR179H 524H 524H 524H Z48N11S05A Z48N11S07A Z48N11S10A 1,985. 2,375. 2,870. 15 25 — — — — EPZ EPZ 115 115 19 22-3/8 13-3/8 16-3/8 10-1/2 14-1/2 216 375 483 567 340 416 267 359 98 170 FR180H FR182H 524H 524H Z48N11S15A Z48N11S25A 3,530. 5,190. Dimensions do not include the conduit for cable entry and exit. Note: For 316 grade stainless steel enclosure replace 10th character of catalog number with an “SS” suffix. Table 9-70. Three-Phase Selection Information — Type EPTZ, 60 Hz kVA Full Cap. Taps FCAN Type FCBN °C Dimensions (Inches) Temp. H W D Rise Dimensions (mm) Wt. kg H W D Frame 116 143 166 275 340 403 403 442 405 419 419 500 211 251 251 265 53 65 75 125 FR201H FR200H FR103H FR95H 70A 70A 70A 70A Z48G28T03A Z48G28T06A Z48G28T09A Z48G28T15A 2,645. 3,085. 3,825. 5,470. 12-3/4 14-5/8 15-5/8 422 660 1275 676 673 781 638 724 765 324 372 397 191 299 580 FR243H FR244H FR245H 66A 66A 66A Z48G28T30A Z48G28T45A Z48G28T75A 9,720. 11,130. 14,490. Wt. Lbs. Wiring Style Diagram Number Number Price U.S. $ 480 ∆ Volts to 208Y/120 Volts Three-Phase 3 6 9 15 — — — — 2@-5% 2@-5% 2@-5% 2@-5% EPTZ EPTZ EPTZ EPTZ 115 115 115 115 13-3/8 15-7/8 15-7/8 17-3/8 16 8-3/8 16-1/2 9-7/8 16-1/2 9-7/8 19-11/16 10-7/16 30 45 75 — — — 2@-5% 2@-5% 2@-5% EPTZ EPTZ EPTZ 115 115 115 26-5/8 26-1/2 30-3/4 25-1/4 28-1/2 30-1/8 480 ∆ Volts to 240 ∆ Volts with 120 Volt Lighting Tap on B Phase 6 9 15 — — — 2@-5% 2@-5% 2@-5% EPTZ EPTZ EPTZ 115 115 115 13-1/8 19-9/16 14-15/16 21-7/8 21-3/4 22-5/16 6-1/4 7-3/8 11-3/8 115 160 340 333 379 552 497 556 567 158 187 289 52 73 155 FR102H FR97H FR195H 95A 95A 95A Z48G22T06A Z48G22T09A Z48G22T15A 3,395. 4,205. 6,010. 30 45 — — 2@-5% 2@-5% EPTZ EPTZ 115 115 26-5/8 26-1/2 12-3/4 14-5/8 422 660 676 673 638 724 324 372 191 299 FR243H FR244H 95A 95A Z48G22T30A Z48G22T45A 10,690. 12,230. 25-1/4 28-1/2 Dimensions do not include the conduit for cable entry and exit. Center Tap capacity limited to 5% of rated kVA. Note: For 316 grade stainless steel enclosure replace 10th character of catalog number with an “SS” suffix. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Open Type Core and Coil Assembly Transformers 9-63 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0363] Single- and Three-Phase, Types DS-3C, DT-3C, 60 Hz Product Description ■ 220°C insulation system, 150°C Rise standard. ■ Aluminum windings (copper optional). Application Description The basic purpose of a transformer is voltage transformation as near as practically possible to the load for economy and distribution of power. Typical loads for dry-type distribution transformers include lighting, heating, air conditioners, fans, and machine tools. Such loads are found in commercial, institutional, industrial, and residential structures. Open core and coil assemblies are typically used by panel builders and equipment OEM customers who incorporate the entire transformer into their structures. A versatile option to purchasing a standard, enclosed transformer and discarding the unneeded enclosure parts. Features, Benefits and Functions ■ (UL recognized). ■ 60 Hz operation standard, 50/60 Hz operation available. ■ Short-term overload capability as required by ANSI. ■ Meet NEMA ST-20 sound levels. Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. Seismically Qualified All Cutler-Hammer manufactured drytype distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. Options and Accessories Please refer to Page 9-120. The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Sound Levels All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Table 9-72. Average Sound Levels Product Specifications NEMA ST-20 Average Sound Level (dB) kVA Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-71. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The following pages provide listings for most standard transformer ratings and styles. Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Winding Terminations Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Series-Multiple Windings Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications Please refer to Page 9-122. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Open Type Core and Coil Assembly Transformers 9-64 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0364] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-73. Single-Phase Selection Information — Type DS-3C, 60 Hz kVA Full Cap. Taps FCAN Type FCBN °C Dimensions (Inches) Temp. H W D Rise Wt. Lbs. 150 150 150 150 147 212 306 340 Dimensions (mm) D Wt. kg Frame W 428 574 574 574 402 445 495 495 67 96 139 154 FR815C FR816C FR817C FR818C Wt. Dimensions (mm) Lbs. H W D Wt. kg Frame Wiring Style Diagram Number Number 14 14 14 128 195 250 516 605 629 511 511 511 356 356 356 58 89 114 FR909C FR910C FR912C 280B 280B 280B V48M28T15ZZ V48M28T30ZZ V48M28T45ZZ 1,350. 1,725. 2,100. 25-5/16 19 25-5/16 19 25-5/16 20 395 530 656 746 797 1052 643 643 643 483 483 508 180 241 298 FR914C FR915C FR916C 280B 280B 280B V48M28T75ZZ V48M28T12ZZ V48M28T49ZZ 2,970. 4,300. 5,400. H Wiring Style Diagram Number Number Price U.S. $ 240 x 480 Volts to 120/240 Volts 15 25 37.5 50 DS-3C DS-3C DS-3C DS-3C 30-1/4 31-1/4 37-5/8 37-5/8 16-7/8 22-5/8 22-5/8 22-5/8 15-7/8 17-1/2 19-1/2 19-1/2 768 793 953 953 3XA 3XA 3XA 3XA T20P11S15ZZ T20P11S25ZZ T20P11S37ZZ T20P11S50ZZ 1,440. 1,870. 2,290. 2,780. 1@+5%, 2@–5% at 240 volts primary; 2@+2.5%, 4@–2.5% at 480 volts primary. Table 9-74. Three-Phase Selection Information — Type DT-3C, 60 Hz kVA Full Cap. Taps FCAN 9 FCBN Type °C Dimensions (Inches) Temp. H W D Rise Price U.S. $ 480 ∆ Volts to 208Y/120 Volts 15 30 45 2@+2.5% 4@-2.5% DT-3C 150 2@+2.5% 4@-2.5% DT-3C 150 2@+2.5% 4@-2.5% DT-3C 150 20-5/16 20-1/8 23-13/16 20-1/8 24-3/4 20-1/8 75 112.5 150 2@+2.5% 4@-2.5% DT-3C 150 2@+2.5% 4@-2.5% DT-3C 150 2@+2.5% 4@-2.5% DT-3C 150 29-3/8 31-3/8 41-7/16 Note: Contact your local Cutler-Hammer sale offices for availability of additional Open Type Core and Coil Assemblies. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Filtered Noise Isolation Transformers 9-65 November 2003 Three-Phase Vol. 1, Ref. No. [0365] Three-Phase, 60 Hz Product Description ■ ■ ■ ■ ■ ■ ■ ■ Ventilated enclosures. Indoor applications standard. 220°C insulation system, 150°C rise standard. Aluminum windings (copper available as option). Electrostatic shield. Surge suppression providing protection from voltage surges and spikes. 120 dB common mode noise attenuation. 60 dB transverse mode noise attenuation. Application Description The basic purpose of a transformer is voltage transformation as near as practically possible to the load for economy and distribution of power. Typical loads for dry-type distribution transformers include lighting, heating, air conditioners, fans, and machine tools. Such loads are found in commercial, institutional, industrial, and residential structures. Features, Benefits and Functions Options and Accessories Please refer to Page 9-120. Product Specifications Frequency Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-75. Insulation System Classification ■ UL listed. 60 Hz operation standard, 50/60 Hz operation available. ■ Short-term overload capability as required by ANSI. ■ Meet NEMA ST-20 sound levels. ■ Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. 40°C 40°C 40°C 40°C All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Table 9-76. Average Sound Levels Overload Capability Ambient Sound Levels + Winding Rise + Hot Spot = Temp. Class 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Cutler-Hammer ventilated transformers, Types DS-3, DT-3, MD, and KT, utilize a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. kVA NEMA Average Sound Level in dB 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 9 Applies to general purpose ventilated transformers only. Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Ventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 75°C for ventilated designs. Series-Multiple Windings Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications The following pages provide listings for most standard transformer ratings and styles. Please refer to Page 9-122. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Transformers Filtered Noise Isolation Transformers 9-66 November 2003 Three-Phase Vol. 1, Ref. No. [0366] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-77. Filtered Noise Isolation Transformers kVA Full Cap. Taps FCAN FCBN °C Temp. Rise Dimensions (Inches) H W D Weight Lbs. Dimensions (mm) H W D Weight kg Style Number Price U.S. $ 480 ∆ Volts to 208Y/120 Volts 15 30 45 75 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 4@-2.5% 150 150 150 150 27-3/8 32-1/4 32-1/4 35-3/4 19 24 24 32 16-9/16 18-1/16 18-1/16 23-11/16 210 320 385 555 695 819 819 908 483 610 610 813 421 459 459 602 95 145 175 252 F48M28T15A F48M28T30A F48M28T45A F48M28T75A 5,670. 6,950. 8,175. 10,400. 112.5 150 225 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% 150 150 150 40 46 48 32 35 38-1/2 23-11/16 23-11/16 28-15/16 720 880 1120 1016 1168 1219 813 889 978 602 602 735 327 400 509 F48M28T12A F48M28T49A F48M28T22A 11,700. 16,060. 20,650. 208 ∆ Volts to 208Y/120 Volts 15 30 45 75 1@+5% 1@+5% 1@+5% 1@+5% 2@-5% 2@-5% 2@-5% 2@-5% 150 150 150 150 27-3/8 32-1/4 32-1/4 35-3/4 19 24 24 32 16-9/16 18-1/16 18-1/16 23-11/16 210 320 385 555 695 819 819 908 483 610 610 813 421 459 459 602 95 145 175 252 F29R28T15A F29R28T30A F29R28T45A F29R28T75A 6,520. 8,800. 10,200. 13,400. 112.5 150 225 1@+5% 1@+5% 1@+5% 2@-5% 2@-5% 2@-5% 150 150 150 40 46 48 32 35 38-1/2 23-11/16 23-11/16 28-15/16 720 880 1120 1016 1168 1219 813 889 978 602 602 735 327 400 509 F29R28T12A F29R28T49A F29R28T22A 15,850. 23,500. 26,790. 9 Not Seismic Qualified. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Low Sound Transformers 9-67 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0367] Single- and Three-Phase, 60 Hz Application Description Product Specifications Low sound transformers are designed to have average sound levels 3 dB below NEMA ST-20 standards. Frequency Note: Sound levels are measured in a sound room, not at the installation. These quieter transformers are ideal for noise sensitive installations such as schools, hospitals, libraries, and offices. Proper installation procedures should be used to achieve maximum benefit. Type DT-3 Low Sound Transformer Product Description Types EP, EPT ■ ■ ■ ■ ■ ■ ■ ■ Sand and Resin Encapsulated design. Suitable for indoor or outdoor applications. Totally enclosed, non-ventilated enclosures. Enclosures are NEMA 3R rated. Mountable in any position indoors and upright only outdoors. 185ºC Insulation System, 115ºC rise standard. Available in single-phase ratings through 37.5 kVA and 4160 volts primary (EP). Available in three-phase ratings through 75 kVA and 4160 volts primary (EPT). Types DS-3, DT-3 ■ ■ ■ ■ ■ ■ Ventilated, NEMA 2 enclosure standard. Suitable for indoor applications, outdoors when weathershields are also installed. Upright mounting only. 220ºC Insulation System, 150ºC rise standard. Available in single-phase ratings 15 – 167 kVA and up to 4160 volts primary (DS-3). Available in three-phase ratings 15 – 1500 kVA and up to 4160 volts primary (DT-3). Features, Benefits and Functions ■ UL listed. 60 Hz operation. ■ Short-term overload capability as required by ANSI. ■ Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-78. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C Seismically Qualified Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. Options and Accessories Please refer to Page 9-120. The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Cutler-Hammer ventilated transformers, Types DS-3, DT-3, MD, and KT, utilize a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Low Sound Transformers 9-68 November 2003 Single- and Three-Phase Sound Levels Winding Terminations All Eaton’s Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Primary and secondary windings are terminated in the wiring compartment. Ventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 75°C for ventilated designs. Table 9-79. Average Sound Levels NEMA ST-20 Average Sound Level (dB) 9 Vol. 1, Ref. No. [0368] kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Technical Data and Specifications Please refer to Page 9-122. Series-Multiple Windings Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Low Sound Transformers 9-69 November 2003 Three-Phase Vol. 1, Ref. No. [0369] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-80. Low Sound Transformers Type DT-3, 60 Hz kVA Full Cap. Taps FCAN FCBN Type °C Dimensions (Inches) Wt. Dimensions (mm) Wt. Temp. H Lbs. H kg W D W D Rise Frame Wiring Weathershield Style Diagram Catalog Price Number Number Number U.S. $ Price U.S. $ 480 ∆ Volts to 208Y/120 Volts — Aluminum Windings 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 30-1/8 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 230 310 310 765 765 765 511 511 511 359 359 359 69 FR910A 141 FR912A 141 FR912A 280B 280B 280B WS31 WS31 WS31 350. V48M28T15LS42 350. V48M28T30LS42 350. V48M28T45LS42 1,590. 2,050. 2,520. 75 2@+2.5% 112.5 2@+2.5% 150 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-1/4 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 664 712 794 486 585 616 273 FR915B 345 FR916A 499 FR917 280B 280B 280B WS33 WS19 WS34 350. V48M28T75LS47 350. V48M28T12LS47 800. V48M28T49LS47 3,530. 5,075. 6,370. 225 300 500 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1100 1600 2400 1422 1581 1905 794 794 1130 616 768 914 499 FR917 728 FR918A 1089 FR919 280B 280B 275A WS34 WS34 WS35 800. V48M28T22LS52 800. V48M28T33LS52 1,360. V48M28T55LS57 9,325. 11,800. 18,900. 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 664 359 359 486 69 FR910A 141 FR912A 218 FR914B 280B 280B 280B WS31 WS31 WS33 350. V48M28F15LS42 350. V48M28F30LS42 350. V48M28F45LS42 1,890. 2,330. 2,840. 75 2@+2.5% 112.5 2@+2.5% 150 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 39-3/8 46-1/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 760 1100 1000 1171 1422 664 712 794 486 585 616 273 FR915B 345 FR916A 499 FR917 280B 280B 280B WS33 WS19 WS34 350. V48M28F75LS47 350. V48M28F12LS47 800. V48M28F49LS47 4,010. 5,805. 7,290. 225 300 500 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 62-1/4 62-1/4 75 31-1/4 31-1/4 44-1/2 30-1/4 30-1/4 36 1600 1600 2400 1581 1581 1905 794 794 1130 768 768 914 728 FR918A 728 FR918A 1089 FR919 280B 280B 275A WS34 WS34 WS35 800. V48M28F22LS52 800. V48M28F33LS52 1,360. V48M28F55LS57 10,660. 13,700. 21,700. 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 765 765 1000 511 511 664 359 359 486 104 FR910A 141 FR912A 218 FR914B 280B 280B 280B WS31 WS31 WS33 350. V48M28B15LS42 350. V48M28B30LS42 350. V48M28B45LS42 2,160. 2,680. 3,360. 75 2@+2.5% 112.5 2@+2.5% 150 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 46-1/8 46-1/8 56 28 28 31-1/4 23 23 24-1/4 760 760 1100 1171 1171 1422 712 712 794 585 585 616 345 FR916A 345 FR916A 499 FR917 280B 280B 280B WS19 WS19 WS34 350. V48M28B75LS47 350. V48M28B12LS47 800. V48M28B49LS47 4,610. 6,660. 8,370. 225 300 4@-2.5% 4@-2.5% DT-3 DT-3 80 80 62-1/4 75 31-1/4 44-1/2 30-1/4 36 1600 2400 1581 1905 794 1130 768 914 728 FR918A 1089 FR919 280B 275A WS34 WS35 800. V48M28B22LS52 1,360. V48M28B33LS52 12,245. 16,000. 2@+2.5% 2@+2.5% 480 ∆ Volts to 208Y/120 Volts — Copper Windings 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 172 300 370 635 765 765 511 511 511 359 359 359 78 FR909 136 FR910A 168 FR912A 280B 280B 280B WS31 WS31 WS31 350. V48M28T15CULS42 350. V48M28T30CULS42 350. V48M28T45CULS42 3,000. 2,770. 3,360. 75 2@+2.5% 112.5 2@+2.5% 150 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 550 675 850 1000 1000 1171 664 664 712 486 486 585 250 FR914B 361 FR915B 386 FR916A 280B 280B 280B WS33 WS33 WS19 350. V48M28T75CULS47 350. V48M28T12CULS47 350. V48M28T49CULS47 5,050. 6,900. 9,510. 225 300 500 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 150 150 150 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1200 2150 3100 1422 1581 1905 794 794 1130 616 768 914 545 FR917 977 FR918A 1409 FR919 280B 280B 275A WS34 WS34 WS35 800. V48M28T22CULS52 800. V48M28T33CULS52 1,360. V48M28T55CULS57 12,690. 16,000. 25,800. 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 25 30-1/8 30-1/8 20-1/8 20-1/8 20-1/8 14-1/8 14-1/8 14-1/8 172 300 370 635 765 765 511 511 511 359 359 359 78 FR909 136 FR910A 168 FR912A 280B 280B 280B WS31 WS31 WS31 350. V48M28F15CULS42 350. V48M28F30CULS42 350. V48M28F45CULS42 2,600. 3,150. 3,800. 75 2@+2.5% 112.5 2@+2.5% 150 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 39-3/8 39-3/8 46-1/8 26-1/8 26-1/8 28 19-1/8 19-1/8 23 550 675 850 1000 1000 1171 664 664 712 486 486 585 250 FR914B 361 FR915B 386 FR916A 280B 280B 280B WS33 WS33 WS19 350. V48M28F75CULS47 350. V48M28F12CULS47 350. V48M28F49CULS47 5,750. 7,860. 10,700. 225 300 500 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 115 115 115 56 62-1/4 75 31-1/4 31-1/4 44-1/2 24-1/4 30-1/4 36 1200 2150 3100 1422 1581 1905 794 794 1130 616 768 914 545 FR917 977 FR918A 1409 FR919 280B 280B 275A WS34 WS34 WS35 800. V48M28F22CULS52 800. V48M28F33CULS52 1,360. V48M28F55CULS57 14,340. 18,000. 29,300. 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 300 370 550 765 765 1000 511 511 664 359 359 486 136 FR910A 168 FR912A 250 FR914B 280B 280B 280B WS31 WS31 WS33 350. V48M28B15CULS42 350. V48M28B30CULS42 350. V48M28B45CULS42 3,000. 3,280. 4,370. 75 2@+2.5% 112.5 2@+2.5% 150 2@+2.5% 4@-2.5% 4@-2.5% 4@-2.5% DT-3 DT-3 DT-3 80 80 80 46-1/8 46-1/8 56 28 28 31-1/4 23 23 24-1/4 850 850 1200 1171 1171 1422 712 712 794 585 585 616 386 FR916A 386 FR916A 545 FR917 280B 280B 280B WS19 WS19 WS34 350. V48M28B75CULS47 350. V48M28B12CULS47 800. V48M28B49CULS47 6,630. 9,090. 12,400. 225 300 4@-2.5% 4@-2.5% DT-3 DT-3 80 80 62-1/4 75 31-1/4 44-1/2 30-1/4 36 2150 3100 1581 1905 794 1130 768 914 728 FR918A 1409 FR919 280B 275A WS34 WS35 800. V48M28B22CULS52 1,360. V48M28B33CULS52 16,650. 20,950. 2@+2.5% 2@+2.5% Note: Contact Cutler-Hammer for availability of lower sound level designs. Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Marine Duty Transformers 9-70 November 2003 Single- and Three-Phase Single- and Three-Phase, Types EPM, DS-3M, EPTM, DT-3M, 60 Hz Product Description Types EP, EPT ■ ■ ■ ■ ■ 9 ■ ■ ■ ■ Sand and Resin Encapsulated design. Suitable for indoor or outdoor applications. Totally enclosed, non-ventilated enclosures. Enclosures are NEMA 3R rated. Mountable in any position indoors and upright only outdoors. 185ºC Insulation System, 115ºC rise standard. Copper windings standard. Available in single-phase ratings through 37.5 kVA and 4160 volts primary (EP). Available in three-phase ratings through 75 kVA and 4160 volts primary (EPT). Types DS-3, DT-3 ■ ■ ■ ■ ■ ■ ■ Ventilated, NEMA 2 enclosure standard. Suitable for indoor applications, outdoors when weathershields are also installed. Upright mounting only. 220ºC Insulation System, 115ºC rise standard. Copper windings standard Available in single-phase ratings 15 – 167 kVA and up to 4160 volts primary (DS-3). Available in three-phase ratings 15 – 1500 kVA and up to 4160 volts primary (DT-3). Application Description The basic purpose of a transformer is voltage transformation as near as practically possible to the load for economy and distribution of power. Typical loads for dry-type distribution transformers include lighting, heating, air conditioners, fans, and machine tools. Such loads are found in commercial, institutional, industrial, and residential structures. Vol. 1, Ref. No. [0370] Features, Benefits and Functions ■ ■ ■ ■ ■ ■ ■ ■ ■ UL listed. Meets IEEE-45 specifications. Meets Public Health Service Publication 393 (Rodent Protection). Meets ABS (American Bureau of Shipping) specification. 60 Hz operation. 115°C temperature rise standard. Copper windings standard. Short-term overload capability as required by ANSI. Meet NEMA ST-20 sound levels. Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-81. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Cutler-Hammer ventilated transformers, Types DS-3M, DT-3M, utilize a NEMA 2 rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. CutlerHammer encapsulated transformers, Types EPM, EPTM, utilize a NEMA 3R rated enclosure. Sound Levels Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Overload Capability Table 9-82. Average Sound Levels Options and Accessories Please refer to Page 9-120. Product Specifications Frequency Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. For more information visit: www.cutler-hammer.eaton.com kVA NEMA Average Sound Level in dB 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 Applies to general purpose ventilated transformers only. CA08101001E Transformers Marine Duty Transformers 9-71 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0371] Winding Terminations Series-Multiple Windings Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Ventilated transformers have leads brought out to aluminum pads that are pre-drilled to accept Cu/Al lugs. Lugs are not supplied with these transformers. Eaton’s Cutler-Hammer business recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications Please refer to Page 9-122. Product Selection Additional Product Selection information begins on Page 9-136. Table 9-83. Marine Duty Transformers Single-Phase Selection Information — Types EPM, DS-3M, 60 Hz Per ABS Requirements, all Marine Duty Transformers are 115ºC and Copper Windings kVA Full Cap. Taps FCAN Type FCBN °C Temp. Rise Dimensions (Inches) Height Width Depth 7 7-1/2 8 Weight Lbs. Dimensions (mm) Height Width Depth 9 Weight kg Style Number Price U.S. $ 240 x 480 Volts to 120/240 Volts 3 5 7.5 — — — — — — EPM EPM EPM 115 115 115 14-3/4 15 23 7 8 12-1/2 10 15 25 — — — — EPM EPM DS-3M 115 115 115 23 23 31 12-1/2 13 16 37.5 50 75 DS-3M DS-3M DS-3M 115 115 115 35 35 39 DS-3M DS-3M 115 115 50 50 100 167 70 100 170 375 381 584 178 203 318 178 191 203 32 45 77 Q20N11S03CU Q20N11S05CU Q20N11S07CU 1,320. 1,450. 1,880. 8 14 19 180 170 270 584 584 787 318 330 406 203 356 483 82 77 122 Q20N11S10CU Q20N11S15CU R20P11F25CU 2,280. 2,780. 3,580. 19-1/2 19-1/2 24 21 21 25 420 490 650 889 889 991 495 495 610 533 533 635 191 222 295 R20P11F37CU R20P11F50CU R20P11F75CU 4,570. 5,360. 6,860. 32 32 28-1/2 28-1/2 920 1160 1270 1270 813 813 724 724 417 526 R20P11F99CU R20P11F67CU 9,130. 14,900. Weight kg Style Number Not seismic qualified. Taps 1 @ +5%, 2 @ –5% at 240 volts; 2 @ +2.5%, 4 @ 2.5% at 480 volts. Table 9-84. Marine Duty Transformers Three-Phase Selection Information — Types EPTM, DT-3M, 60 Hz Per ABS Requirements, all Marine Duty Transformers are 115ºC and Copper Windings kVA Full Cap. Taps FCAN Type FCBN °C Temp. Rise Dimensions (Inches) H W D Weight Lbs. Dimensions (mm) H W D Price U.S. $ 480 ∆ Volts to 208Y/120 Volts 3 6 9 2@+2.5% 2@+2.5% 2@+2.5% 2@-2.5% EPTM 2@-2.5% EPTM 2@-2.5% EPTM 115 115 115 16-1/2 19 21-1/2 12-1/2 16-1/2 17-7/16 15 30 45 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% DT-3M 4@-2.5% DT-3M 4@-2.5% DT-3M 115 115 115 22 29 29 16-3/4 21-1/2 21-1/2 75 112.5 150 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% DT-3M 4@-2.5% DT-3M 4@-2.5% DT-3M 115 115 115 38 41 41 225 300 500 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% DT-3M 2@-2.5% DT-3M 2@-2.5% DT-3M 115 115 115 6 6 7 100 190 275 419 483 546 318 419 443 152 152 178 45 86 125 L48D28T03CU L48D28T06CU L48D28T09CU 2,230. 2,510. 2,720. 15 19-1/2 19-1/2 190 305 405 559 737 737 425 546 546 381 495 495 86 138 184 M48M28F15CU M48M28F30CU M48M28F45CU 3,085. 3,950. 5,350. 26 32 32 21 25-1/2 25-1/2 650 850 1020 965 1041 1041 660 813 813 533 648 648 295 386 463 M48M28F75CU M48M28F12CU M48M28F49CU 7,010. 8,500. 10,850. 51-1/2 51-1/2 59 39-1/2 39-1/2 48-1/2 34 34 38 1450 1680 2550 1308 1308 1499 1003 1003 1232 864 864 965 658 762 1157 M48M28F22CU M48D28F33CU M48D28F55CU 14,830. 19,200. 31,020. 480 ∆ Volts to 240 ∆ Volts 6 9 15 30 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 2@-2.5% 2@-2.5% 4@-2.5% 4@-2.5% EPTM EPTM DT-3M DT-3M 115 115 115 115 19 21-1/2 22 29 16-1/2 17-7/16 16-3/4 21-1/2 6 7 15 19-1/2 190 275 190 305 483 546 559 737 419 443 425 546 152 178 318 495 86 125 86 138 L48D24T06CU L48D24T09CU M48M24F15CU M48M24F30CU 2,510. 2,880. 3,085. 3,950. 45 75 112.5 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% DT-3M 4@-2.5% DT-3M 4@-2.5% DT-3M 115 115 115 29 38 41 21-1/2 26 32 19-1/2 21 25-1/2 405 650 850 737 965 1041 546 660 813 495 533 648 184 295 386 M48M24F45CU M48M24F75CU M48M24F12CU 5,350. 7,010. 8,500. 150 225 300 500 2@+2.5% 2@+2.5% 2@+2.5% 2@+2.5% 4@-2.5% 4@-2.5% 2@-2.5% 2@-2.5% 115 115 115 115 41 51-1/2 51-1/2 59 32 39-1/2 39-1/2 48-1/2 25-1/2 34 34 38 1020 1450 1680 2550 1041 1308 1308 1499 813 1003 1003 1232 648 864 864 965 463 658 762 1157 M48M24F49CU M48M24F22CU M48D24F33CU M48D24F55CU 10,850. 14,890. 19,200. 32,775. DT-3M DT-3M DT-3M DT-3M Not seismic qualified. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com Transformers Buck-Boost Transformers 9-72 November 2003 Single- and Three-Phase Single- and Three-Phase Applications, 60 Hz Vol. 1, Ref. No. [0372] Features, Benefits and Functions ■ UL listed. 60 Hz operation. ■ 600 volt class insulation. ■ Short-term overload capability as required by ANSI. ■ Meet NEMA ST-20 sound levels. ■ Standards and Certifications Industry Standards Type EP 9 Product Description Types EP, EPT ■ ■ ■ ■ ■ ■ ■ ■ Sand and Resin Encapsulated design. Suitable for indoor or outdoor applications. Totally enclosed, non-ventilated enclosures. Enclosures are NEMA 3R rated. Mountable in any position indoors and upright only outdoors. 185ºC Insulation System, 115ºC rise standard. Available in single-phase ratings through 37.5 kVA and 4160 volts primary (EP). Available in three-phase ratings through 75 kVA and 4160 volts primary (EPT). Application Description A buck-boost transformer is used to provide an economical method of correcting a lower or higher voltage rating more suitable for efficient operation of electrical equipment. Type EP Buck-Boost transformers are small kVA, single-phase transformers with dual primary and dual secondary windings and are usually connected as autotransformers by utilizing one unit for single-phase applications and either two or three units banked for three-phase operation. They are primarily used for motor operation and should not be used for motor control circuits, to correct fluctuating line voltage or to obtain a neutral on a delta system. All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. Options and Accessories Please refer to Page 9-120. Product Specifications Frequency Cutler-Hammer buck-boost transformers are designed for 60 Hz operation. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-85. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Enclosures Cutler-Hammer encapsulated buckboost transformers utilize a NEMA 3R rated enclosure. Sound Levels All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Table 9-86. Average Sound Levels Overload Capability NEMA ST-20 Average Sound Level (dB) Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. kVA Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. For more information visit: www.cutler-hammer.eaton.com Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Lugs are not supplied with these transformers. The Cutler-Hammer business recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs. CA08101001E Transformers Buck-Boost Transformers 9-73 November 2003 Vol. 1, Ref. No. [0373] Series-Multiple Windings Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications Please refer to Page 9-122. Note: When installation is to be made on a grounded system, consideration must be given to the resulting voltage. Thus, on a 208 grounded wye/120 system the voltage can be boosted to 240 volts but the voltage to ground will be 139 volts. If 240/120 volts with a mid-point ground is needed, a standard two-winding transformer must be used. The following formulas can be used to calculate specific requirements. For Single-Phase: Load Voltage x Full Line Amperes LOAD kVA = --------------------------------------------1000 For Three-Phase: Line Load Voltage x 1.73 x Full Load Amperes LOAD kVA = -----------------------------------------------------------------1000 CA08101001E Single- and Three-Phase Product Selection 5-Step Selector For quick selection data, refer to the tables on the following pages. The tables which follow will simplify the selection of the buck-boost transformers. There are no calculations needed; simply follow these 5 steps. Selection Requirements You should have the following information before selecting a buck-boost transformer. Line Voltage The voltage that you want to buck (decrease) or boost (increase). This can be found by measuring the supply line voltage with a voltmeter. Load Voltage The voltage at which your equipment is designed to operate. This is listed on the nameplate of the load equipment. Load Amperes or Load kVA You do not need to know both — one or the other is sufficient for selection purposes. This information usually can be found on the nameplate of the equipment that you want to operate. Frequency The supply line frequency must be the same as the frequency of the equipment to be operated — Eaton’s CutlerHammer Buck-Boost Transformers operate at 60 Hz only. Phase The supply line should be the same as the equipment to be operated — either single or three-phase. Transformer Interconnection For three-phase applications, interconnections of transformers should be made in a junction box. Two or three transformers may be used depending on an open delta (2) or wye (3) connection. For more information visit: www.cutler-hammer.eaton.com 1. Refer to the table having the same output voltage as the equipment you want to operate. For example, if you are installing a 240 volt 6 kVA single-phase load use Selection Table 9-91. 2. Select the available line voltage across the top of the chart which is closest to the actual supply voltage. Therefore, for example, if the available line voltage is 213 volts, use the 212 volt column. 3. Read down the column until you reach an output kVA or amps rating equal to or greater than the load requirements. Since 6 kVA, in the example, is not listed, use the next higher rating or 7.5 kVA. 4. Read across to the far left columns for the catalog number and quantity of transformers for your application. In this case, you will need one (1) catalog number S10N06A01N. 5. Connect the buck-boost transformer(s) you have selected in accordance with the connection diagram specified at the bottom of the available line voltage column. In this example, Diagram “F” would be used. Note: For 1-phase connections and 3-phase open delta connections, inputs and outputs may be reversed. kVA capacity remains constant. Additional Product Selection information begins on Page 9-136. 9 Transformers Buck-Boost Transformers 9-74 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0374] Wiring Diagrams Diagram A Diagram B Diagram C High Voltage X3 X4 X1 X2 X1 X2 X3 X3 X4 X1 X2 H3 H3 H4 H3 H4 H2 H1 H2 H1 H2 Diagram E Diagram F Low Voltage X1 High Voltage High Voltage X2 X3 X4 H4 H3 H2 H1 X3 X4 X1 X2 H4 H3 X1 H2 H1 H4 X2 H4 X4 H2 X3 X4 X1 X2 X3 X2 X1 X3 X4 X4 X3 X2 X2 X1 H1 H1 H2 Low Voltage X1 X2 X3 X4 X4 X3 X2 X1 H4 H3 H2 H1 H1 H2 H3 H4 X1 X2 X3 X4 X4 X3 X2 X1 H4 H3 H2 H1 H1 H2 H3 H4 High Voltage Low Voltage Low Voltage Diagram M Diagram N High Voltage Diagram O Low Voltage High Voltage X4 X3 X4 X1 X3 X2 H1 H2 H3 H4 Diagram L High Voltage X1 X3 X4 X2 Low Voltage Diagram K X4 X4 X1 H4 H3 H2 H1 H1 High Voltage H2 X3 Low Voltage High Voltage Diagram J H1 High Voltage H2 H1 H2 Diagram I High Voltage X3 H3 H3 X4 Low Voltage Diagram H Low Voltage X1 X2 X3 Low Voltage High Voltage Diagram G H1 High Voltage Low Voltage Diagram D X3 X4 H4 Low Voltage 9 Low Voltage High Voltage X1 X4 X3 X2 X1 X4 X3 X4 X3 X4 X3 X4 X3 X2 X4 X1 H4 X2 H3 X1 H4 X2 H3 X1 H4 X2 H3 H4 H3 H4 H3 H4 H3 X1 H4 X2 H3 X1 H4 X2 H3 X1 H4 X2 H3 H2 H1 H2 H1 H2 H1 H2 H1 H2 H1 H2 H1 H2 H1 H2 H1 H2 H1 Low Voltage Neutral Diagram Q X3 X4 X2 X4 X2 X4 X3 X1 X3 H4 H3 H4 H3 H4 H3 H2 H1 H2 H1 H2 H1 X1 X3 X1 X2 H3 H4 X4 X3 H3 H4 X2 X1 H1 H2 High Voltage X3 X4 X2 H3 H4 X1 H1 H2 H3 H1 H4 H2 Low Voltage H3 H4 X3 X2 X1 H1 H2 High Voltage X4 X3 H3 H4 X1 X2 X4 H4 H3 H1 H2 H4 X3 X1 X2 X4 H3 H1 X3 X2 X4 H3 H1 H2 H4 H2 Low Voltage Neutral Neutral Diagram U High Voltage High Voltage X4 X3 X1 X2 Diagram T Low Voltage X2 X4 X1 H1 H2 Neutral High Voltage Diagram S X1 X3 X4 X1 Neutral Diagram R High Voltage Low Voltage X2 High Voltage Neutral Low Voltage Diagram P X3 X4 X4 X3 X1 X2 X2 X1 X3 X4 X1 X2 H1 H4 H2 H1 H1 H4 Low Voltage Neutral H1 H4 Low Voltage Figure 9-2. Buck-Boost Transformers Wiring Diagrams WARNING! If input is 3-wire, “neutral” connection must be isolated and insulated! When used to supply a 3-phase, 4-wire load, the source must be 3-phase, 4-wire wye. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Buck-Boost Transformers 9-75 November 2003 Single- and Three-Phase Vol. 1, Ref. No. [0375] Table 9-87. Selection Information kVA °C Temp. Rise Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Frame Style Number Price U.S. $ FR52 FR54 FR55 S10N04A81N S10N04A82N S10N04A83N 100. 105. 115. 120 x 240 Volts to 12/24 Volts .05 .10 .15 115 115 115 6-1/2 6-1/2 6-1/2 3-7/8 3-7/8 3-7/8 3-1/2 3-1/2 3-1/2 7 7 8 165 165 165 98 98 98 89 89 89 3 3 4 .25 .50 .75 115 115 115 6-1/2 6-1/2 8-3/8 4-7/8 4-7/8 6 3-7/8 4-5/8 5-3/4 12 13 21 165 165 213 124 124 152 98 117 146 5 5 10 FR56 FR57 FR58A S10N04A26N S10N04A51N S10N04A76N 150. 175. 230. 1 1.5 2 115 115 115 8-3/8 10-3/4 10-3/4 6 6-3/16 6-3/16 5-3/4 6-1/8 6-1/8 31 40 40 213 273 273 152 157 157 146 156 156 14 18 18 FR59A FR67 FR68 S10N04A01N S10N04A16N S10N04A02N 270. 360. 470. 3 5 7.5 115 115 115 14-1/8 16 16 7-11/16 10-3/8 10-3/8 8 9-7/8 9-7/8 65 113 123 359 406 406 195 263 263 203 251 251 29 51 55 FR176 FR177 FR178 S10N04A03N S10N04A05N S10N04A07N 635. 1,180. 1,650. FR52 FR54 FR55 S10N06A81N S10N06A82N S10N06A83N 100. 105. 115. 120 x 240 Volts to 16/32 Volts .05 .10 .15 115 115 115 6-1/2 6-1/2 6-1/2 3-7/8 3-7/8 3-7/8 3-1/2 3-1/2 3-1/2 7 7 8 165 165 165 98 98 98 89 89 89 3 3 4 .25 .50 .75 115 115 115 6-1/2 6-1/2 8-3/8 4-7/8 4-7/8 6 3-7/8 4-5/8 5-3/4 12 13 21 165 165 213 124 124 152 98 117 146 5 5 10 FR56 FR57 FR58A S10N06A26N S10N06A51N S10N06A76N 150. 175. 230. 1 1.5 2 115 115 115 8-3/8 10-3/4 10-3/4 6 6-3/16 6-3/16 5-3/4 6-1/8 6-1/8 31 40 40 213 273 273 152 157 157 146 156 156 14 18 18 FR59A FR67 FR68 S10N06A01N S10N06A16N S10N06A02N 270. 360. 470. 3 5 7.5 115 115 115 14-1/8 16 16 7-11/16 10-3/8 10-3/8 8 9-7/8 9-7/8 65 113 123 359 406 406 195 263 263 203 251 251 29 51 55 FR176 FR177 FR178 S10N06A03N S10N06A05N S10N06A07N 635. 1,180. 1,650. FR52 FR54 FR55 S20N08A81N S20N08A82N S20N08A83N 110. 125. 135. 240 x 480 Volts to 24/48 Volts .05 .10 .15 115 115 115 6-1/2 6-1/2 6-1/2 3-7/8 3-7/8 3-7/8 3-1/2 3-1/2 3-1/2 7 7 8 165 165 165 98 98 98 89 89 89 3 3 4 .25 .50 .75 115 115 115 6-1/2 6-1/2 8-3/8 4-7/8 4-7/8 6 3-7/8 4-5/8 5-3/4 12 13 21 165 165 213 124 124 152 98 117 146 5 5 10 FR56 FR57 FR58A S20N08A26N S20N08A51N S20N08A76N 165. 210. 270. 1 1.5 2 115 115 115 8-3/8 10-3/4 10-3/4 6 6-3/16 6-3/16 5-3/4 6-1/8 6-1/8 31 40 40 213 273 273 152 157 157 146 156 156 14 18 18 FR59A FR67 FR68 S20N08A01N S20N08A16N S20N08A02N 310. 420. 570. 3 5 7.5 115 115 115 14-1/8 16 16 7-11/16 10-3/8 10-3/8 8 9-7/8 9-7/8 65 113 123 359 406 406 195 263 263 203 251 251 29 51 55 FR176 FR177 FR178 S20N08A03N S20N08A05N S20N08A07N 740. 1,290. 2,000. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Buck-Boost Transformers 9-76 November 2003 Single-Phase Vol. 1, Ref. No. [0376] Table 9-88. Single-Phase 115 Volt Output Required, 60 Hz Units Unit Required kVA Input Available Voltage 84 91 Output 9 96 Output 100 Output Style Number 102 Output Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 1 1 1 .05 .05 .10 — .13 — — 1.14 — — .18 — — 1.56 — .24 — .48 2.09 — 4.17 — .31 — — 2.70 — — .36 — — 3.13 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 1 1 1 .10 .15 .15 .26 — .39 2.29 — 3.44 .36 — .54 3.12 — 4.69 — .72 — — 6.25 — .62 — .93 5.41 — 8.12 .72 — 1.08 6.25 — 9.37 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 1 1 1 .25 .25 .50 — .659 — — 5.73 — — .899 — — 7.81 — 1.2 — 2.4 10.4 — 20.8 — 1.56 — — 13.5 — — 1.8 — — 15.6 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 1 1 1 .50 .75 .75 1.32 — 1.98 11.5 — 17.2 1.8 — 2.7 15.6 — 23.4 — 3.6 — — 31.2 — 3.11 — 4.67 27.1 — 40.6 3.59 — 5.39 31.2 — 46.8 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 1 1 1 1 1 1.5 — 2.64 — — 22.9 — — 3.59 — — 31.2 — 4.79 — 7.2 41.7 — 62.5 — 6.23 — — 54.1 — — 7.19 — — 62.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 1 1 1 1.5 2 2 3.95 — 5.27 34.4 — 45.8 5.39 — 7.19 46.9 — 62.5 — 9.58 — — 83.3 — 9.34 — 12.5 81.2 — 108 10.8 — 14.4 93.7 — 125 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 1 1 1 3 3 5 — 7.92 — — 68.7 — — 10.77 — — 93.6 — 14.37 — 23.95 125.1 — 208.5 — 18.69 — — 162.3 — — 21.57 — — 187.5 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 1 1 1 5 7.5 7.5 13.2 — 19.8 115 — 172 18 — 27 156 — 234 — 36 — — 312 — 31.15 — 46.7 270.5 — 406 35.95 — 53.9 312.5 — 468 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram D Unit Units Required kVA Input Available Voltage B 105 127 Output Output B C A 130 138 146 Output Output Style Number Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 1 1 1 .05 .05 .10 .48 — .96 4.17 — 8.33 .54 — 1.1 4.58 — 9.17 — .41 — — 3.54 — .29 — .58 2.5 — 5.0 — .23 — — 1.98 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 1 1 1 .10 .15 .15 — 1.44 — — 12.5 — — 1.6 — — 13.7 — .82 — 1.3 7.08 — 10.6 — .87 — — 7.5 — .46 — .69 3.95 — 5.93 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 1 1 1 .25 .25 .50 2.39 — 4.79 20.8 — 41.6 2.63 — 5.27 22.9 — 45.8 — 2.03 — — 17.7 — 1.44 — 2.87 12.5 — 25 — 1.14 — — 9.88 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 1 1 1 .50 .75 .75 — 7.19 — — 62.4 — — 7.9 — — 68.7 — 4.07 — 6.1 35.4 — 53.1 — 4.31 — — 37.5 — 2.27 — 3.41 19.8 — 29.6 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 1 1 1 1 1 1.5 9.58 — 14.4 83.3 — 125 10.5 — 15.8 91.7 — 137 — 8.14 — — 70.8 — 5.75 — 8.62 50 — 75 — 4.55 — — 39.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 1 1 1 1.5 2 2 — 19.2 — — 16.7 — — 21.1 — — 183 — 12.2 — 16.3 106 — 142 — 11.5 — — 100 — 6.82 — 9.10 59.3 — 79.2 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 1 1 1 3 3 5 28.7 — 47.9 249.9 — 416.5 31.5 — 52.5 275.1 — 458.5 — 24.4 — — 212.4 — 17.3 — 28.7 150 — 250 — 13.6 — — 118.5 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 1 1 1 5 7.5 7.5 — 71.9 — — 624 — — 79 — — 687 — 40.7 — 61 354 — 531 — 43.1 — — 357 — 22.7 — 34.1 197.5 — 296 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram A A A B B Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Buck-Boost Transformers 9-77 November 2003 Single-Phase Vol. 1, Ref. No. [0377] Table 9-89. Single-Phase 120 Volt Output Required, 60 Hz Units Unit Required kVA Input Available Voltage 88 95 Output 100 Output 104 Output Style Number 106 Output Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 1 1 1 .05 .05 .10 — .14 — — 1.15 — — .19 — — 1.56 — .25 — .50 2.09 — 4.17 — .33 — — 2.70 — — .38 — — 3.13 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 1 1 1 .10 .15 .15 .28 — .41 2.29 — 3.44 .38 — .56 3.12 — 4.69 — .75 — — 6.25 — .65 — .98 5.41 — 8.12 .75 — 1.12 6.25 — 9.37 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 1 1 1 .25 .25 .50 — .687 — — 5.73 — — .937 — — 7.81 — 1.25 — 2.5 10.4 — 20.8 — 1.62 — — 13.5 — — 1.87 — — 15.6 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 1 1 1 .50 .75 .75 1.37 — 2.06 11.5 — 17.2 1.87 — 2.82 15.6 — 23.4 — 3.75 — — 31.2 — 3.25 — 4.87 27.1 — 40.6 3.75 — 5.62 31.2 — 46.8 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 1 1 1 1 1 1.5 — 2.75 — — 22.9 — — 3.75 — — 31.2 — 5 — 7.5 41.7 — 62.5 — 6.5 — — 54.1 — — 7.5 — — 62.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 1 1 1 1.5 2 2 4.12 — 5.5 34.4 — 45.8 5.62 — 7.5 46.9 — 62.5 — 10 — — 83.3 — 9.75 — 13 81.2 — 108 11.2 — 15 93.7 — 125 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 1 1 1 3 3 5 — 8.25 — — 68.7 — — 11.25 — — 93.6 — 15 — 25 125.1 — 208.5 — 19.5 — — 162.3 — — 22.5 — — 187.5 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 1 1 1 5 7.5 7.5 13.75 — 20.6 114.5 — 172 18.75 — 28.2 156 — 234 — 37.5 — — 312 — 32.5 — 48.7 270.5 — 406 37.5 — 56.2 312.5 — 468 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram D Unit Units Required kVA Input Available Voltage B 109 132 Output Output B C A 136 144 152 Output Output Style Number Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 1 1 1 .05 .05 .10 .5 — 1.0 4.17 — 8.33 .55 — 1.1 4.58 — 9.17 — .43 — — 3.54 — .3 — .6 2.5 — 5.0 — .24 — — 1.98 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 1 1 1 .10 .15 .15 — 1.5 — — 12.5 — — 1.6 — — 13.7 — .85 — 1.27 7.08 — 10.6 — .9 — — 7.5 — .48 — .71 3.95 — 5.93 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 1 1 1 .25 .25 .50 2.5 — 5 20.8 — 41.6 2.75 — 5.5 22.9 — 45.8 — 2.12 — — 17.7 — 1.5 — 3 12.5 — 25 — 1.19 — — 9.88 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 1 1 1 .50 .75 .75 — 7.5 — — 62.4 — — 8.25 — — 68.7 — 4.25 — 6.37 35.4 — 53.1 — 4.5 — — 37.5 — 2.37 — 3.56 19.8 — 29.6 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 1 1 1 1 1 1.5 10 — 15 83.3 — 125 11 — 16.5 91.7 — 137 — 8.5 — — 70.8 — 6 — 9 50 — 75 — 4.75 — — 39.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 1 1 1 1.5 2 2 — 20 — — 167 — — 22 — — 183 — 12.7 — 17 106 — 142 — 12 — — 100 — 7.12 — 9.5 59.3 — 79.2 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 1 1 1 3 3 5 30 — 50 249.9 — 416.5 33 — 55 275.1 — 458.5 — 25.5 — — 212.4 — 18 — 30 150 — 250 — 14.25 — — 118.5 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 1 1 1 5 7.5 7.5 — 75 — — 624 — — 82.5 — — 687 — 42.5 — 63.7 354 — 531 — 45 — — 375 — 23.7 — 35.6 197.5 — 296 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram A A A B B Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol. . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Buck-Boost Transformers 9-78 November 2003 Single-Phase Vol. 1, Ref. No. [0378] Table 9-90. Single-Phase 230 Volt Output Required, 60 Hz Units Unit Required kVA Input Available Voltage 199 203 Output 9 207 Output 209 Output kVA Amps kVA Amps kVA — — 1.36 — — .36 — — 1.56 — — .72 — 1.08 3.12 — 4.69 Style Number 216 Output Price U.S. $ Output Amps kVA Amps kVA Amps .48 — .96 2.08 — 4.17 — .72 .86 1.88 — 3.75 — — 3.12 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. — 1.29 — — 5.62 — — 1.44 — — 6.25 — 1.44 — 2.16 6.25 — 9.37 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 1 1 1 .05 .05 .10 1 1 1 .10 .15 .15 — .93 2.71 — 4.06 1 1 1 .25 .25 .50 — 1.55 — — 6.77 — — 1.8 — — 7.81 — 2.15 — 4.31 9.37 — 18.7 2.39 — 4.79 10.4 — 20.8 — 3.59 — — 15.6 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 1 1 1 .50 .75 .75 3.11 — 4.66 13.5 — 20.3 3.6 — 5.4 15.6 — 23.4 — 6.46 — — 28.2 — — 7.19 — — 31.2 — 7.19 — 10.8 31.2 — 46.8 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. .31 — .62 .43 1 1 1 1 1 1.5 — 6.23 — — 27.1 — — 7.2 — — 31.2 — 8.62 — 12.9 37.5 — 56.2 9.58 — 14.4 41.7 — 62.5 — 14.4 — — 62.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 1 1 1 1.5 2 2 9.34 — 12.5 40.6 — 54.2 10.8 — 14.4 46.9 — 62.5 — 17.2 — — 75 — — 19.2 — — 83.3 — 21.6 — 28.7 93.7 — 125 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 1 1 1 3 3 5 — 18.6 — — 81.3 — — 21.6 — — 93.6 — 25.8 — 43.1 112.5 — 187.5 28.7 — 47.9 125.1 — 208.5 — 43.2 — — 187.5 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 1 1 1 5 7.5 7.5 31.1 — 46.6 135.5 — 203 36 — 54 156 — 234 — 64.6 — — 282 — — 71.9 — — 312 — 72 — 108 312.5 — 468 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram G Unit Units Required kVA 219 F G F E 246 253 260 Input Available Voltage 242 Output Output Output Output Style Number Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 1 1 1 .05 .05 .10 .96 — 1.92 4.16 — 8.33 1.0 — 2.01 4.38 — 8.75 — .77 — — 3.34 — .53 — 1.05 2.29 — 4.58 — .41 — — 1.77 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 1 1 1 .10 .15 .15 — 2.87 — — 12.5 — — 3.02 — — 13.1 — 1.53 — 2.3 6.67 — 10.0 — 1.58 — — 6.87 — .82 — 1.22 3.54 — 5.31 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 1 1 1 .25 .25 .50 4.79 — 9.58 20.8 — 41.6 5.03 — 10.1 21.9 — 43.7 — 3.83 — — 16.7 — 2.63 — 5.27 11.5 — 22.9 — 2.04 — — 8.85 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 1 1 1 .50 .75 .75 — 14.4 — — 62.4 — — 15.1 — — 65.6 — 7.67 — 11.5 33.3 — 50 — 7.9 — — 34.4 — 4.07 — 6.11 17.7 — 26.6 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 1 1 1 1 1 1.5 19.2 — 28.7 83.3 — 125 20.1 — 30.2 87.5 — 131 — 15.3 — — 66.7 — 10.5 — 15.8 45.8 — 68.7 — 8.15 — — 35.4 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 1 1 1 1.5 2 2 — 38.3 — — 167 — — 40.2 — — 175 — 23 — 30.7 100 — 133 — 21.1 — — 91.7 — 12.2 — 16.3 53.1 — 70.8 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 1 1 1 3 3 5 57.6 — 96 249.9 — 416.5 60.3 — 100.5 262.5 — 437.5 — 45.9 — — 200.1 — 31.5 — 52.5 137.4 — 229 — 24.4 — — 106.2 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 1 1 1 5 7.5 7.5 — 144 — — 624 — — 151 — — 656 — 76.5 — 115 333.5 — 500 — 79 — — 344 — 40.7 — 61.1 177 — 266 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram E E E F F Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol. . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Buck-Boost Transformers 9-79 November 2003 Single-Phase Vol. 1, Ref. No. [0379] Table 9-91. Single-Phase 240 Volt Output Required, 60 Hz Units Unit Required kVA Input Available Voltage 208 212 Output 216 Output Output kVA Amps kVA Amps kVA — — 1.35 — — — 1.56 — — 1 1 1 .05 .05 .10 1 1 1 .10 .15 .15 — 1 1 1 .25 .25 .50 1 1 1 .50 .75 .75 .32 — .65 .38 — .75 218 Style Number 225 Output Price U.S. $ Output Amps kVA Amps kVA Amps 1.88 — 3.75 .5 — 1.0 2.08 — 4.17 — .75 — — 3.12 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. — 1.35 — — 5.62 — — 1.5 — — 6.25 — 1.5 — 2.25 6.25 — 9.37 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. .45 .9 .98 2.71 — 4.06 — 1.12 3.12 — 4.69 — 1.62 — — 6.77 — — 1.87 — — 7.81 — 2.25 — 4.5 9.37 — 18.7 2.5 — 5 10.4 — 20.8 — 3.75 — — 15.6 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 3.25 — 4.87 13.5 — 20.3 3.75 — 5.62 15.6 — 23.4 — 6.75 — — 28.2 — — 7.5 — — 31.2 — 7.5 — 11.2 31.2 — 46.8 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 1 1 1 1 1 1.5 — 6.5 — — 27.1 — — 7.5 — — 31.2 — 9 — 13.5 37.5 — 56.2 10 — 15 41.7 — 62.5 — 15 — — 62.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 1 1 1 1.5 2 2 9.75 — 13 40.6 — 54.2 11.2 — 15 46.9 — 62.5 — 18 — — 75 — — 20 — — 83.3 — 22.5 — 30 93.7 — 125 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 1 1 1 3 3 5 — 19.5 — — 81.3 — — 22.5 — — 93.6 — 27 — 45 112.5 — 187 30 — 50 125.1 — 208 — 45 — — 187.5 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 1 1 1 5 7.5 7.5 32.5 — 48.7 135 — 203 37.5 — 56.2 156 — 234 — 67.5 — — 282 — — 75 — — 312 — 75 — 112 312 — 468 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram G Unit Units Required kVA Input Available Voltage F 229 252 Output Output G F E 256 264 272 Output Output Style Number Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 1 1 1 .05 .05 .10 1.0 — 2.0 4.16 — 8.33 1.05 — 2.1 4.38 — 8.75 — .55 — 1.1 2.29 — 4.58 .42 — — 3.33 — — .8 — — 1.77 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 1 1 1 .10 .15 .15 — 3.0 — — 12.5 — — 3.15 — — 13.1 — 1.6 — 2.4 6.67 — 10.0 — 1.65 — — 6.87 — .85 — 1.27 3.54 — 5.31 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 1 1 1 .25 .25 .50 5 — 10 20.8 — 41.6 5.25 — 10.5 21.9 — 43.7 — 4 — — 16.7 — 2.75 — 5.5 11.5 — 22.9 — 2.12 — — 8.85 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 1 1 1 .50 .75 .75 — 15 — — 62.4 — — 15.7 — — 65.6 — 8 — 12 33.3 — 50 — 8.25 — — 34.4 — 4.25 — 6.37 17.7 — 26.6 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 1 1 1 1 1 1.5 20 — 30 83.3 — 125 21 — 31.5 87.5 — 131 — 16 — — 66.7 — 11 — 16.5 45.8 — 68.7 — 8.5 — — 35.4 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 1 1 1 1.5 2 2 — 40 — — 167 — — 42 — — 175 — 24 — 32 100 — 133 — 22 — — 91.7 — 12.7 — 17 53.1 — 70.8 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 1 1 1 3 3 5 60 — 100 249.9 — 416.5 63 — 105 262.5 — 437.5 — 48 — — 200.1 — 33 — 55 137.4 — 229 — 25.5 — — 106.2 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 1 1 1 5 7.5 7.5 — 150 — — 624 — — 157 — — 656 — 80 — 120 333 — 500 — 82.5 — — 344 — 42.5 — 63.7 177 — 266 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram E E E F F Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Buck-Boost Transformers 9-80 November 2003 Three-Phase Vol. 1, Ref. No. [0380] Table 9-92. Three-Phase Open Delta Connection 230 Volt Output Required, 60 Hz Units Unit Required kVA Input Available Voltage 199 203 Output 9 207 Output 209 Output Style Number 216 Output Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 2 2 2 .05 .05 .10 — .62 — — 1.35 — — .54 — — 1.56 — .75 — 1.49 1.87 — 3.75 .83 — 1.66 2.08 — 4.17 — 1.24 — — 3.12 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 2 2 2 .10 .15 .15 1.08 — 1.62 2.71 — 4.06 1.24 — 1.87 3.12 — 4.69 — 2.24 — — 5.62 — — 2.49 — — 6.25 — 2.49 — 3.73 6.25 — 9.37 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 2 2 2 .25 .25 .50 — 2.7 — — 6.77 — — 3.11 — — 7.81 — 3.3 — 7.47 9.37 — 18.7 4.15 — 8.3 10.4 — 20.8 — 6.22 — — 15.6 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 2 2 2 .50 .75 .75 5.39 — 8.09 13.5 — 20.3 6.22 — 9.33 15.6 — 23.4 — 11.2 — — 28.2 — — 12.4 — — 31.2 — 12.4 — 18.7 31.2 — 46.8 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 2 2 2 1 1 1.5 — 10.8 — — 27.1 — — 12.4 — — 31.2 — 14.9 — 22.4 37.5 — 56.2 16.6 — 24.9 41.7 — 62.5 — 24.9 — — 62.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 2 2 2 1.5 2 2 16.2 — 21.6 40.6 — 54.2 18.7 — 24.9 46.9 — 62.5 — 29.9 — — 75 — — 33.2 — — 83.3 — 37.3 — 49.8 93.7 — 125 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 2 2 2 3 3 5 — 32.4 — — 81.3 — — 32.7 — — 93.6 — 44.7 — 74.7 112.5 — 187 49.8 — 83 125.1 — 208 — 74.7 — — 187.5 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 2 2 2 5 7.5 7.5 53.9 — 80.9 135 — 203 62.2 — 93.3 156 — 234 — 112 — — 282 — — 124 — — 312 — 124 — 187 312.5 — 468 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram L Unit Units Required kVA Input Available Voltage K 219 242 Output Output L K I 246 253 260 Output Output Style Number Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 2 2 2 .05 .05 .10 1.66 — 3.32 4.17 — 8.33 1.74 — 3.48 4.37 — 8.75 — 1.33 — — 3.33 — .91 — 1.83 2.29 — 4.58 — .70 — — 1.77 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 2 2 2 .10 .15 .15 — 4.98 — — 12.5 — — 5.23 — — 13.1 — 2.65 — 3.98 6.67 — 10.0 — 2.74 — — 6.87 — 1.41 — 2.12 3.54 — 5.13 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 2 2 2 .25 .25 .50 8.3 — 16.6 20.8 — 41.7 8.71 — 17.4 21.9 — 43.7 — 6.64 — — 16.7 — 4.56 — 9.73 11.5 — 22.9 — 3.52 — — 8.85 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 2 2 2 .50 .75 .75 — 24.9 — — 62.4 — — 26.1 — — 65.6 — 13.3 — 19.9 33.3 — 50 — 13.7 — — 34.4 — 7.05 — 10.6 17.7 — 26.6 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 2 2 2 1 1 1.5 33.2 — 49.8 83.3 — 125 34.8 — 52.3 87.5 — 131 — 26.5 — — 66.7 — 18.3 — 27.4 45.8 — 68.7 — 14.1 — — 35.4 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 2 2 2 1.5 2 2 — 66.4 — — 167 — — 69.7 — — 175 — 39.8 — 53.1 100 — 133 — 36.5 — — 91.7 — 21.2 — 28.2 53.1 — 70.8 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 2 2 2 3 3 5 99.6 — 166 249.9 — 417 104.4 — 174 262.5 — 437 — 79.5 — — 200 — 54.9 — 91.3 137.4 — 229 — 42.3 — — 106.2 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 2 2 2 5 7.5 7.5 — 249 — — 624 — — 261 — — 656 — 133 — 199 333 — 500 — 137 — — 344 — 70.5 — 106 177 — 266 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram I I I K K Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Buck-Boost Transformers 9-81 November 2003 Three-Phase Vol. 1, Ref. No. [0381] Table 9-93. Three-Phase Open Delta Connection 240 Volt Output Required, 60 Hz Units Unit Required kVA Input Available Voltage 208 212 Output 216 Output 218 Output Style Number 225 Output Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 2 2 2 .05 .05 .10 — .65 — — 1.35 — — .56 — — 1.56 — .73 — 1.56 1.87 — 3.75 .87 — 1.73 2.08 — 4.17 — 1.3 — — 3.12 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 2 2 2 .10 .15 .15 1.13 — 1.69 2.71 — 4.06 1.3 — 1.95 3.12 — 4.69 — 2.34 — — 5.62 — — 2.6 — — 6.25 — 2.6 — 3.9 6.25 — 9.37 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 2 2 2 .25 .25 .50 — 2.81 — — 6.77 — — 3.25 — — 7.81 — 3.9 — 7.79 9.37 — 18.7 4.33 — 8.66 10.4 — 20.8 — 6.49 — — 15.6 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 2 2 2 .50 .75 .75 5.63 — 8.44 13.5 — 20.3 6.5 — 9.75 15.6 — 23.4 — 11.7 — — 28.2 — — 13 — — 31.2 — 13 — 19.5 31.2 — 46.8 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 2 2 2 1 1 1.5 — 11.3 — — 27.1 — — 13 — — 31.2 — 15.6 — 23.4 37.5 — 56.2 17.3 — 26 41.7 — 62.5 — 26 — — 62.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 2 2 2 1.5 2 2 16.9 — 22.5 40.6 — 54.2 19.5 — 26 46.9 — 62.5 — 31.2 — — 75 — — 34.6 — — 83.3 — 39 — 52 93.7 — 125 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 2 2 2 3 3 5 — 33.9 — — 81.3 — — 39 — — 93.6 — 46.8 — 77.9 112.5 — 187 51.9 — 86.6 125.1 — 208 — 78 — — 187.5 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 2 2 2 5 7.5 7.5 56.3 — 84.4 135 — 203 65 — 97.5 156 — 234 — 117 — — 282 — — 130 — — 312 — 130 — 195 312 — 468 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram L Unit Units Required kVA 229 K L K I 256 264 272 Input Available Voltage 252 Output Output Output Output Style Number Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 2 2 2 .05 .05 .10 1.73 — 3.46 4.16 — 8.33 1.82 — 3.64 4.37 — 8.75 — 1.38 — — 3.33 — .95 — 1.91 2.29 — 4.58 — .74 — — 1.77 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 2 2 2 .10 .15 .15 — 5.19 — — 12.5 — — 5.45 — — 13.1 — 2.77 — 4.15 6.67 — 10.0 — 2.86 — — 6.87 — 1.47 — 2.21 3.54 — 5.31 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 2 2 2 .25 .25 .50 8.66 — 17.3 20.8 — 41.6 9.09 — 18.2 21.9 — 43.7 — 6.92 — — 16.7 — 4.76 — 9.53 11.5 — 22.9 — 3.68 — — 8.85 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 2 2 2 .50 .75 .75 — 26 — — 62.4 — — 27.3 — — 65.6 — 13.8 — 20.8 33.3 — 50 — 14.3 — — 34.4 — 7.36 — 11 17.7 — 26.6 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 2 2 2 1 1 1.5 34.6 — 51.9 83.3 — 125 36.4 — 54.5 87.5 — 131 — 27.7 — — 66.7 — 19.1 — 28.6 45.8 — 68.7 — 14.7 — — 35.4 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 2 2 2 1.5 2 2 — 69.3 — — 167 — — 72.7 — — 175 — 41.5 — 55.4 100 — 133 — 38.1 — — 91.7 — 22.1 — 29.4 53.1 — 70.8 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 2 2 2 3 3 5 103.8 — 173 249.9 — 416 109.2 — 182 262.5 — 437 — 83.1 — — 200 — 57.3 — 95.3 137.4 — 229 — 44.1 — — 106.2 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 2 2 2 5 7.5 7.5 — 260 — — 624 — — 273 — — 656 — 138 — 208 333 — 500 — 143 — — 344 — 73.6 — 110 177 — 266 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram I I I K K Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Buck-Boost Transformers 9-82 November 2003 Three-Phase Vol. 1, Ref. No. [0382] Table 9-94. Three-Phase Wye Connection 208 Volt Output Required, 60 Hz Note: WARNING! Three-phase autotransformers should never be used to obtain 4-wire output with 3-wire input. 4-wire output requires 4-wire wye input. Units Unit Required kVA Input Available Voltage 152 164 Output 9 173 Output 180 Output Style Number 184 Output Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 3 3 3 .05 .05 .10 — — 1.15 — — .75 — 1.50 2.08 — 4.17 .98 — — 1.56 — — — — — 2.71 — — 1.12 — — 3.12 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 3 3 3 .10 .15 .15 .82 — 1.24 2.29 — 3.44 1.12 — 1.69 3.12 — 4.69 — 2.25 — — 6.25 — 1.95 — 2.92 5.41 — 8.12 2.25 — 3.73 6.25 — 9.37 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 3 3 3 .25 .25 .50 — 2.06 — — 5.73 — — 2.81 — — 7.81 — 3.75 — 7.5 10.4 — 20.8 — 4.87 — — 13.5 — — 5.62 — — 15.6 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 3 3 3 .50 .75 .75 4.12 — 6.19 11.5 — 17.2 5.62 — 8.44 15.6 — 23.4 — 11.2 — — 31.2 — 9.75 — 14.6 27.1 — 40.6 11.2 — 16.8 31.2 — 46.8 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. .41 .56 3 3 3 1 1 1.5 — 8.25 — — 22.9 — — 11.2 — — 31.2 — 15 — 22.5 41.7 — 62.5 — 19.5 — — 54.1 — — 22.5 — — 62.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 3 3 3 1.5 2 2 12.4 — 16.5 34.4 — 45.8 16.9 — 22.5 46.9 — 62.5 — 30 — — 83.3 — 29.2 — 39 81.2 — 108 33.7 — 45 93.7 — 125 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 3 3 3 3 3 5 — 24.7 — — 68.7 — — 33.6 — — 93.6 — 45 — 75 125 — 208 — 58.5 — — 162.3 — — 67.5 — — 187.5 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 3 3 3 5 7.5 7.5 41.2 — 61.9 115 — 172 56.2 — 84.4 156 — 234 — 112 — — 312 — 97.5 — 146 271 — 406 112 — 168 312 — 468 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram P Unit Units Required kVA 189 N N O M 236 250 264 Input Available Voltage 229 Output Output Output Output Style Number Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 3 3 3 .05 .05 .10 1.5 — 3.0 4.16 — 8.33 1.65 — 3.3 4.58 — 9.17 — 1.27 — — 3.54 — .9 — 1.8 2.5 — 5.0 — .71 — — 1.98 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 3 3 3 .10 .15 .15 — 4.5 — — 12.5 — — 4.95 — — 13.7 — 2.55 — 3.82 7.08 — 10.6 — 2.7 — — 7.5 — 1.42 — 2.14 3.95 — 5.93 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 3 3 3 .25 .25 .50 7.5 — 15 20.8 — 41.6 8.25 — 16.5 22.9 — 45.8 — 6.35 — — 17.7 — 4.5 — 9 12.5 — 25 — 3.56 — — 9.88 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 3 3 3 .50 .75 .75 — 22.5 — — 62.4 — — 24.7 — — 68.7 — 12.7 — 19 35.4 — 53.1 — 13.5 — — 37.5 — 7.12 — 10.7 19.3 — 29.3 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 3 3 3 1 1 1.5 30 — 45 83.3 — 125 33 — 49.5 91.7 — 137 — 25.5 — — 70.8 — 18 — 27 50 — 75 — 14.2 — — 39.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 3 3 3 1.5 2 2 — 60 — — 167 — — 66 — — 183 — 38.2 — 51 106 — 142 — 361 — — 100 — 21.4 — 28.5 59.3 — 79.2 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 3 3 3 3 3 5 90 — 150 249.9 — 416 99 — 165 275.1 — 458 — 76.5 — — 212.4 — 54 — 90 150 — 250 — 46.2 — — 118.5 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 3 3 3 5 7.5 7.5 — 225 — — 624 — — 274 — — 687 — 127 — 190 354 — 531 — 135 — — 375 — 71.2 — 107 198 — 293 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram M M M N N Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Buck-Boost Transformers 9-83 November 2003 Three-Phase Vol. 1, Ref. No. [0383] Table 9-95. Three-Phase Wye Connection 230 Volt Output Required, 60 Hz Note: WARNING! Three-phase autotransformers should never be used to obtain 4-wire output with 3-wire input. 4-wire output requires 4-wire wye input. Units Unit Required kVA Input Available Voltage 183 192 Output 199 Output 208 Output Style Number 218 Output Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 3 3 3 .05 .05 .10 — — 1.56 — .83 — 1.66 2.08 — 4.17 — .54 — — — 1.35 — 1.65 — 3.3 4.58 — 9.17 1.66 — 3.32 4.17 — 8.35 S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 3 3 3 .10 .15 .15 1.25 — 1.87 3.12 — 4.69 — 2.49 — — 6.25 — 1.08 — 1.62 2.71 — 4.06 — 4.95 — — 13.7 — — 4.98 — — 12.5 — S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 3 3 3 .25 .25 .50 — 3.11 — — 7.81 — 4.15 — 8.3 10.4 — 20.8 — 2.70 — — 6.77 — 8.2 — 16.5 22.9 — 45.8 8.3 — 16.6 20.9 — 41.7 S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 3 3 3 .50 .75 .75 6.22 — 9.33 15.6 — 23.4 — 12.4 — — 31.2 — 5.39 — 8.09 13.5 — 20.3 — 24.7 — — 68.8 — — 24.9 — — 62.6 — S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. .62 3 3 3 1 1 1.5 — 12.5 — — 31.2 — 16.6 — 24.9 41.7 — 62.5 — 10.8 — — 27.1 — 33 — 49.5 91.7 — 137 33.2 — 49.8 83.5 — 125 S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 3 3 3 1.5 2 2 18.7 — 24.9 46.9 — 62.5 — 33.2 — — 83.3 — 16.2 — 21.6 40.6 — 54.2 — 66 — — 183 — — 66.4 — — 167 — S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 3 3 3 3 3 5 — 37.5 — — 93.6 — 49.8 — 83 125.1 — 208 — 32.4 — — 81.3 — 99 — 165 275 — 458 99.6 — 166 250.5 — 417 S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 3 3 3 5 7.5 7.5 62.2 — 93.3 156 — 234 — 124 — — 312 — 53.9 — 80.9 135 — 203 — 247 — — 688 — — 249 — — 626 — S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram N Unit Units Required kVA Input Available Voltage N 242 245 Output Output S M Q 253 260 265 Output Output Style Number Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 3 3 3 .05 .05 .10 1.74 — 3.48 4.37 — 8.75 — 1.33 — — 3.33 — .91 — 1.83 2.29 — 4.58 — .62 — — 1.77 — — .70 — — 1.56 — S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 3 3 3 .10 .15 .15 — 5.23 — — 13.1 — 2.65 — 3.98 6.67 — 10.0 — 2.74 — — 6.87 — 1.41 — 2.12 3.54 — 5.31 1.25 — 1.87 3.12 — 4.69 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 3 3 3 .25 .25 .50 8.71 — 17.4 21.9 — 43.7 — 6.63 — — 16.7 — 4.56 — 9.31 11.5 — 22.9 — 3.52 — — 8.85 — — 3.11 — — 7.81 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 3 3 3 .50 .75 .75 — 26.1 — — 65.6 — 13.3 — 19.9 33.3 — 50 — 13.7 — — 34.4 — 7.05 — 10.6 17.7 — 26.6 6.22 — 9.33 15.6 — 23.4 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 3 3 3 1 1 1.5 34.8 — 52.3 87.5 — 131 — 26.5 — — 66.7 — 18.3 — 27.4 45.8 — 68.7 — 14.1 — — 35.4 — — 12.5 — — 31.2 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 3 3 3 1.5 2 2 — 69.7 — — 175 — 39.8 — 53.1 100 — 133 — 36.6 — — 91.6 — 21.2 — 28.2 53.1 — 70.8 18.7 — 24.9 46.9 — 62.5 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 3 3 3 3 3 5 104.4 — 174 262.5 — 437 — 79.5 — — 200 — 54.9 — 91.3 137.4 — 229 — 42.3 — — 106.2 — — 37.5 — — 93.6 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 3 3 3 5 7.5 7.5 — 261 — — 656 — 133 — 199 333 — 500 — 137 — — 344 — 70.5 — 106 177 — 266 62.2 — 93.3 156 — 234 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram Q Q R R S Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Buck-Boost Transformers 9-84 November 2003 Three-Phase Vol. 1, Ref. No. [0384] Table 9-96. Three-Phase Wye Connection 240 Volt Output Required, 60 Hz Note: WARNING! Three-phase autotransformers should never be used to obtain 4-wire output with 3-wire input. 4-wire output requires 4-wire wye input. Units Unit Required kVA Input Available Voltage 190 200 Output 9 208 Output 218 Output Style Number 228 Output Price U.S. $ Output kVA Amps kVA Amps kVA Amps kVA Amps kVA Amps 3 3 3 .05 .05 .10 — .65 — — 1.65 — .86 — 1.73 2.08 — 4.17 — 1.27 — — 3.05 — .86 — 1.73 2.08 — 4.17 1.73 — 3.46 4.17 — 8.34 S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 3 3 3 .10 .15 .15 1.3 — 1.95 3.12 — 4.69 — 2.59 — — 6.25 — 2.55 — 3.82 6.12 — 9.16 — 2.59 — — 6.25 — — 5.20 — — 12.5 — S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 3 3 3 .25 .25 .50 — 3.25 — — 7.81 — 4.32 — 8.65 10.4 — 20.8 — 6.3 — — 15.1 — 4.32 — 8.65 10.4 — 20.8 8.66 — 17.3 20.9 — 41.7 S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 3 3 3 .50 .75 .75 6.5 — 9.75 15.6 — 23.4 — 13 — — 31.2 — 12.7 — 19.2 30.4 — 46 — 13 — — 31.2 — — 26 — — 62.6 — S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 3 3 3 1 1 1.5 — 13 — — 31.2 — 17.3 — 25.9 41.7 — 62.5 — 25.5 — — 61.2 — 17.3 — 25.9 41.7 — 62.5 34.6 — 52 83.4 — 125 S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 3 3 3 1.5 2 2 19.5 — 26 46.9 — 62.5 — 34.6 — — 83.3 — 38.2 — 51 91.6 — 122.4 — 34.6 — — 83.3 — — 69.3 — — 167 — S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 3 3 3 3 3 5 — 39 — — 93.6 — 51.9 — 86.5 125.1 — 208 — 76.5 — — 183.6 — 51.9 — 86.5 125.1 — 208 103.8 — 173 250.2 — 417 S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 3 3 3 5 7.5 7.5 65 — 97.5 156 — 234 — 130 — — 312 — 127.2 — 192 305.2 — 460 — 130 — — 312 — — 260 — — 626 — S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram N Unit Units Required kVA 252 N M R Q 264 272 277 Input Available Voltage 256 Output Output Output kVA Amps kVA Amps kVA Output Style Number Price U.S. $ Output Amps kVA Amps kVA Amps — — .74 .65 S10N04A81N S10N06A81N S10N04A82N 100. 100. 105. 3 3 3 .05 .05 .10 1.85 — 3.64 4.37 — 8.75 — 1.39 — — 3.33 — — 1.91 2.29 — 4.58 — — 1.77 — — — 1.56 — 3 3 3 .10 .15 .15 — 5.46 — — 13.1 — 2.77 — 4.16 6.67 — 10.0 — 2.86 — — 6.87 — 1.47 — 2.21 3.54 — 5.31 1.3 — 1.95 3.12 — 4.69 S10N06A82N S10N04A83N S10N06A83N 105. 115. 115. 3 3 3 .25 .25 .50 9.09 — 18.2 21.9 — 43.7 — 6.93 — — 16.7 — 4.76 — 9.53 11.5 — 22.9 — 3.68 — — 8.85 — — 3.25 — — 7.81 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 3 3 3 .50 .75 .75 — 27.3 — — 65.6 — 13.9 — 20.8 33.3 — 50 — 14.3 — — 34.4 — 7.36 — 11 17.7 — 26.6 6.5 — 9.75 15.6 — 23.4 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. .95 3 3 3 1 1 1.5 36.4 — 54.6 87.5 — 131 — 27.7 — — 66.7 — 19.1 — 28.6 45.8 — 68.7 — 14.7 — — 35.4 — — 13 — — 31.2 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 3 3 3 1.5 2 2 — 72.8 — — 175 — 41.6 — 55.4 100 — 133 — 38.1 — — 91.7 — 22.1 — 29.5 53.1 — 70.8 19.5 — 26 46.9 — 62.5 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 3 3 3 3 3 5 109.2 — 182 262.5 — 437 — 83.1 — — 200 — 57.3 — 95.3 137.4 — 229 — 44.1 — — 106.2 — — 39 — — 93.6 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 3 3 3 5 7.5 7.5 — 273 — — 656 — 139 — 208 333 — 500 — 143 — — 344 — 73.6 — 110 177 — 266 65 — 97.5 156 — 234 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram Q Q R R S Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Buck-Boost Transformers 9-85 November 2003 Three-Phase Vol. 1, Ref. No. [0385] Table 9-97. Three-Phase Wye Connection 460 Volt Output Required, 60 Hz Note: WARNING! Three-phase autotransformers should never be used to obtain 4-wire output with 3-wire input. 4-wire output requires 4-wire wye input. Units Unit Input Available Voltage Required kVA 406 418 Output kVA Output Amps kVA 432 Output Amps kVA 438 424 Output Amps kVA 436 Output Amps kVA Style Number 450 Output Price U.S. $ Output Amps kVA Amps kVA Amps 3 3 3 .05 .05 .10 — — 1.66 2.08 — — 3.22 4.04 — 1.25 1.57 — — 2.49 3.12 — — 1.3 — — 3.31 4.15 — — 6.62 8.31 — 1.7 2.1 1.56 — — 3.5 — — 4.2 — 2.6 — — S10N04A81N 3.13 S10N06A81N — S10N04A82N 100. 100. 105. 3 3 3 .10 .15 .15 2.49 3.12 — — 4.97 6.24 — — 2.6 — — 4.97 6.24 — — 9.94 12.48 — 3.73 4.68 — — 7.46 9.36 — — 3.9 3.12 — — 5.2 4.68 — — 5.2 6.25 — — 7.8 6.25 S10N06A82N — S10N04A83N 9.38 S10N06A83N 105. 115. 115. 3 3 3 .25 .25 .50 — — 8.28 10.39 — 6.22 7.81 — — 12.4 — — 16.6 20.84 — 3 3 3 .50 .75 .75 12.5 — 18.7 — 16.6 15.56 — — 33.2 20.84 — — 6.5 41.67 — — 8.7 7.82 — — 17.4 10.4 — 20.9 — 13 — — 15.6 — S10N04A26N S10N06A26N S10N04A51N 150. 150. 175. 15.69 — — 24.8 23.47 — — 24.69 31.25 — 31.12 — — 49.6 — 37.3 46.82 — — 13 62.25 — — 19.5 15.6 — 23.4 — 26 — — 31.2 — 26 — 39 31.2 — 46.9 S10N06A51N S10N04A76N S10N06A76N 175. 230. 230. 3 3 3 1 1 1.5 — 24.9 — — 33.1 31.25 — — 49.7 41.54 — — 49.7 62.38 — — 66.2 62.38 — — 99.4 83.09 — — 26 124.75 — — 31.2 — 35 — 52 42 — 62.5 — 52 — — 62.5 — S10N04A01N S10N06A01N S10N04A16N 270. 270. 360. 3 3 3 1.5 2 2 37.3 — 49.7 46.94 — — 66.3 62.38 — — 74.6 83.22 — — 99.5 93.63 — — 133 124.88 — — 39 166.93 — — 52 46.8 — 62.5 — 69 — — 82.9 — 78 — 104 93.8 — 125 S10N06A16N S10N04A02N S10N06A02N 360. 470. 470. 3 3 3 3 3 5 — 74.6 — — 99.3 93.63 — — 166 124.64 — — 149 208.35 — — 198.6 187.01 — — 322 249.27 — — 78 404.16 — — 93.8 — 104 — 174 125 — 209.2 — 156 — — 187.6 — S10N04A03N S10N06A03N S10N04A05N 635. 635. 1,180. 3 3 3 5 7.5 7.5 125 — 187 156.89 — — 248 235 — — 311 — 312.53 — — 496 468 — — 622 — 156.3 — 234 — 260 — — 312 — 260 — 390 312.7 — 469 S10N06A05N S10N04A07N S10N06A07N 1,180. 1,650. 1,650. Connection Diagram R R 249 — 373 Q Q 130 — 195 R R Q Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Buck-Boost Transformers 9-86 November 2003 Single-Phase Vol. 1, Ref. No. [0386] Table 9-98. Single-Phase Required, 60 Hz Units Unit Required kVA Input Available Voltage/Output Voltage 200/240 230/277 Output kVA 1 1 1 9 .25 .50 .75 346/380 Output Amps kVA 362/380 Output Amps kVA 378/416 Output Amps kVA Output Amps kVA Style Number 416/457 Price U.S. $ Output Amps kVA Amps 1.25 2.50 3.75 5.2 10.4 15.6 1.44 2.88 4.32 5.2 10.4 15.6 1.98 3.95 5.93 5.2 10.4 15.6 3.95 7.90 11.9 10.4 20.8 31.2 2.16 4.33 6.49 5.2 10.4 15.6 2.38 4.76 7.14 5.2 10.4 15.6 S20N08A26N S20N08A51N S20N08A76N 165. 210. 270. 1 1 1 1 1.5 2 5.00 7.50 10.00 20.8 31.2 41.6 5.76 8.64 11.5 20.8 31.2 41.6 7.90 11.9 15.8 20.8 31.2 41.6 15.8 23.8 31.6 41.6 62.5 83.3 8.65 13.0 17.3 20.8 31.2 41.6 9.52 14.3 19.0 20.8 31.2 41.6 S20N08A01N S20N08A16N S20N08A02N 310. 420. 570. 1 1 1 3 5 7.5 15.0 25.0 37.5 62.5 104.0 156.0 17.3 28.8 43.2 62.5 104.0 156.0 23.8 39.5 59.3 62.5 104.0 156.0 47.5 79.0 118.6 125.0 208.0 312.0 26.0 43.3 64.9 62.5 104.0 156.0 28.6 47.6 71.4 62.5 104.0 156.0 S20N08A03N S20N08A05N S20N08A07N 740. 1,290. 2,000. Connection Diagram B B Units Unit Required kVA Input Available Voltage/Output Voltage 436/480 458/480 Output kVA 1 1 1 .25 .50 .75 F 277/230 Output Amps kVA Output Amps kVA E F F 480/456 504/480 528/480 Output Amps kVA Output Amps kVA Style Number Price U.S. $ Output Amps 2.50 4.99 7.49 5.2 10.4 15.6 4.99 9.98 15.0 10.4 20.8 31.2 1.44 2.88 4.33 6.26 12.5 18.8 5.23 10.4 15.7 11.4 22.8 34.2 5.47 10.9 16.4 11.4 22.8 34.2 kVA 2.75 5.49 8.24 Amps 5.72 11.4 17.2 S20N08A26N S20N08A51N S20N08A76N 165. 210. 270. 1 1 1 1 1.5 2 9.98 15.0 20.0 20.8 31.2 41.6 20.0 30.0 40.0 41.6 62.5 83.3 5.76 8.64 11.5 25.0 37.6 50.1 20.9 31.3 41.8 45.6 68.4 91.2 21.8 32.8 43.7 45.6 68.4 91.2 11.0 16.5 22.0 22.9 34.3 45.8 S20N08A01N S20N08A16N S20N08A02N 310. 420. 570. 1 1 1 3 5 7.5 30.0 49.9 74.9 62.5 104.0 156.0 60.0 99.8 149.8 125.0 208.0 312.0 17.3 28.8 43.2 75.3 125.3 187.9 62.7 104.5 156.8 136.0 227.0 341.0 65.2 108.0 163.0 136.0 227.0 341.0 33.0 54.9 82.4 68.8 114.4 171.6 S20N08A03N S20N08A05N S20N08A07N 740. 1,290. 2,000. Connection Diagram F E B E E F Additional wiring trough may be required. Refer to Page 9-74 for Buck-Boost wiring diagrams. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Buck-Boost Transformers 9-87 November 2003 Three-Phase Vol. 1, Ref. No. [0387] Table 9-99. Three-Phase Required, 60 Hz Unit kVA Input Available Voltage/Output Voltage 362/380 346/416 Output kVA .25 .50 .75 430/473 Output Amps kVA 400/480 Output Amps kVA Output Amps kVA Style Number 436/480 Price U.S. $ Output Amps kVA Amps 6.52 13.0 19.6 10.4 20.8 31.2 3.75 7.50 11.2 5.2 10.4 15.6 4.26 8.52 12.8 5.2 10.4 15.6 4.33 8.65 13.0 5.2 10.4 15.6 4.33 8.65 13.0 5.2 10.4 15.6 S20N08A26N S20N08A51N S20N08A76N 165. 210. 270. 1 1.5 2 26.1 39.1 52.2 41.6 62.4 83.2 15.0 22.5 30.0 20.8 31.2 41.6 17.0 25.5 34.1 20.8 31.2 41.6 17.3 26.0 34.6 20.8 31.2 41.6 17.3 26.0 34.6 20.8 31.2 41.6 S20N08A01N S20N08A16N S20N08A02N 310. 420. 570. 3 5 7.5 78.4 130.4 195.6 125.0 208.0 312.0 45.0 75.1 112.6 62.5 104.0 156.0 51.2 85.2 127.8 62.5 104.0 156.0 52.0 86.6 129.9 62.5 104.0 156.0 52.0 86.6 129.9 62.5 104.0 156.0 S20N08A03N S20N08A05N S20N08A07N 740. 1,290. 2,000. Connection Diagram I N K N K Units Required 2 3 2 3 2 Unit kVA 460/483 Input Available Voltage/Output Voltage 457/380 Output kVA .25 .50 .75 504/480 Output Amps kVA Output Amps kVA Style Number 528/480 Price U.S. $ Output Amps kVA Amps 8.7 17.4 26.1 10.4 20.8 31.2 4.12 8.23 12.3 6.25 12.5 18.8 9.08 18.2 27.2 10.9 21.8 32.8 4.76 9.51 14.3 5.72 11.4 17.2 S20N08A26N S20N08A51N S20N08A76N 165. 210. 270. 1 1.5 2 34.8 52.2 69.6 41.6 62.4 83.2 16.5 24.7 32.9 25.0 37.5 50.0 36.3 54.5 72.6 43.7 65.5 87.4 19.0 28.5 38.0 22.9 34.3 45.8 S20N08A01N S20N08A16N S20N08A02N 310. 420. 570. 3 5 7.5 104.6 174.0 261.0 125.0 208.0 312.0 49.5 82.3 123.5 75.2 125.1 187.6 109.7 181.6 272.4 131.3 218.4 327.6 57.2 95.1 142.7 68.8 114.4 171.6 S20N08A03N S20N08A05N S20N08A07N 740. 1,290. 2,000. Connection Diagram I N I K Units Required 2 3 2 2 Refer to Page 9-74 for Buck-Boost wiring diagrams. Additional wiring trough may be required. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Buck-Boost Transformers 9-88 November 2003 Autotransformer Applications Vol. 1, Ref. No. [0388] Table 9-100. Three-Phase Open Delta Connection 480 Volt Output Required, 60 Hz Units Input Available Voltage Required 600 575 Output kVA 9 Output Style Number 575 Table 9-101. Single-Phase 480 Volt Output Required, 60 Hz Price U.S. kVA Amps kVA Amps kVA Amps 4.3 5.1 — — 6.5 7.8 — — — — — — — — 4.1 4.9 — — S20N11S51N S60G11S51N S20N11S76N 170. 255. 220. 2 2 2 — — 8.6 10.3 — — — — — — — — 6.2 7.4 — — 8.3 9.9 S60G11S76N S20N11S01N S60G11S01N 330. 260. 390. 2 2 2 13.0 15.6 — — 17.2 20.6 — — — — — — — — 12.4 14.9 — — S20N11S16N S60G11S16N S20N11S02N 320. 475. 410. 2 2 2 — — 25.8 31 — — — — — — — — 16.5 19.8 — — 24.8 29.8 S60G11S02N S20N11S03N S60G11S03N 610. 500. 740. 2 2 2 43.2 51.9 — — 65 78.1 — — — — — — — 41 — — 49.3 — S20N11S05N S60G11S05N S20N11S07N 740. 1,110. 980. 2 2 2 — 86 — — 103.4 — — — 83 — — 99.8 62 — — 74.5 — — S60G11S07N S20N11S10N S60G11S10N 1,460. 1,180. 1,760. 2 2 2 130 — 216 156.3 — 259.8 — 124 — — 149.1 — — — — — — — S20N11S15N S60N11S15N T20P11S25 1,540. 2,400. 1,870. 2 2 2 — 324 432 — 389.7 519.6 207 — — 248.9 — — — — — — — — S60J11S25N T20P11S37 T20P11S50 2,825. 2,290. 3,220. Connection Diagram I T Output Style Number 575 Price U.S. Output Amps kVA Amps kVA Amps 1 1 1 2.5 5.2 — — 3.7 7.7 — — — — — — — — 2.4 5 — — S20N11S51N S60G11S51N S20N11S76N 170. 255. 220. 1 1 1 — — 5.0 10.4 — — — — — — — — 3.6 7.5 — — 4.8 10 S60G11S76N S20N11S01N S60G11S01N 330. 260. 390. 1 1 1 7.5 15.6 — — 10 20.8 — — — — — — — — 7.2 15 — — S20N11S16N S60G11S16N S20N11S02N 320. 475. 410. 1 1 1 — 15 — — 31.2 — — — — — — — 9.6 20 — — 14.3 29.7 S60G11S02N S20N11S03N S60G11S03N 610. 500. 740. 1 1 1 25 52 — — 37.5 78.1 — — — — — — — 24 — — 50 — S20N11S05N S60G11S05N S20N11S07N 740. 1,110. 980. 1 1 1 — 50 — — 104.1 — — — 43 — — 100 36 — — 75 — — S60G11S07N S20N11S10N S60G11S10N 1,460. 1,180. 1,760. 1 1 1 75 — 125 156.2 — 260.4 — 72 — — 150 — — — — — — — S20N11S15N S60N11S15N T20P11S25 1,540. 2,400. 1,870. 1 1 1 — 187 250 — 389.6 520.8 120 — — 250 — — — — — — — — S60J11S25N T20P11S37 T20P11S50 2,825. 2,290. 3,220. Connection Diagram E H U Output Output 2 2 2 J Units Input Available Voltage Required 600 575 Additional wiring trough may be required. On transformers supplied with standard taps, taps must be placed at nominal settings. Refer to Page 9-74 for Buck-Boost wiring diagrams. Additional wiring trough may be required. On transformers supplied with standard taps, taps must be placed at nominal settings. Refer to Page 9-74 for Buck-Boost wiring diagrams. Note: Autotransformers can be used only where local electric codes permit and isolation of the two circuits is not required. Rated Output Voltage Note: Output voltage for lower input voltage can be found by: -------------------------------------------------- x Input Actual Voltage = Output New Voltage. Rated Input Voltage Actual Input Voltage Note: Output kVA available at reduced input voltage can be found by: ------------------------------------------------ x Output kVA = New kVA Rating. Rated Input Voltage Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Industrial Control Transformers 9-89 November 2003 Type MTA Vol. 1, Ref. No. [0389] Type MTA Features, Benefits and Functions Product Specifications ■ Cutler-Hammer Type MTA control transformers are designed for 60 Hertz operation. Transformers required for other frequencies are available and must be specifically designed. ■ ■ ■ ■ ■ ■ Type MTA Transformer ■ Product Description ■ Varnish impregnated core and coil design. ■ Suitable for indoor applications. ■ Open core and coil design. Application Description Machine Tool and Industrial Control Transformers provide stepped-down voltages to machine tool control devices enabling control circuits to be isolated from all power and lighting circuits. This allows the use of grounded or ungrounded circuits that are independent of the power or lighting grounds; greater safety is afforded the operator. The control transformer line is particularly adaptable on applications where compact construction is demanded. ■ UL recognized component for units rated 1000 VA and below. CSA certified for units rated 1000 VA and below. 55ºC rise, 105ºC insulation system. 60 Hz operation standard. 100% tested to verify product quality. Performance equals or exceeds requirements of ANSI/NEMA ST-1. Regulation exceeds ANSI/NEMA requirements for all ratings. Each unit must pass rigid tests for turns ratio, insulation, continuity, and over potential. 50 – 5000 VA ratings. Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. Frequency Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-102. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Series-Multiple Windings Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications Please refer to Page 9-122. The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Industrial Control Transformers 9-90 November 2003 Type MTA Vol. 1, Ref. No. [0390] Overcurrent Protection Tables Overcurrent protection on both the primary and secondary sides of transformers are specified in UL 508 and the National Electrical Code. The maximum acceptable ratings are shown below. Due to high inrush currents present when a transformer is initially energized, it is recommended that the primary fuse be time delay to prevent nuisance trips during startup. Table 9-103. Maximum Acceptable Rating of Primary Overcurrent Protection Primary VA Rating Voltage 25 50 9 75 100 150 200 250 300 350 500 750 1000 1500 2000 3000 5000 7000 115 6/10 (1) 1-1/4 (2) 1-8/10 2-1/2 (3-2/10) (4) 3-1/2 (6-1/4) 5 (8) 4 5 5 8 10 15 20 25 — — — 120 6/10 (1) 1-1/4 (2) 1-8/10 (3) 3-1/2 (6-1/4) 5 (8) 4 5 5 8 10 15 15 20 — — — 200 3/10 (6/10) 3/4 (1-1/4) 1-1/8 1-1/2 (1-8/10) (2-1/2) 2-1/4 (3-1/2) 3 (5) 3-1/2 (6-1/4) 4-1/2 (7-1/2) 5 (8) 4-1/2 7 9 15 15 20 — — 208 3/10 (6/10) 6/10 (1-1/8) 1 1-4/10 (1-8/10) (2-1/4) 2 (3-1/2) 2-8/10 (4-1/2) 3-1/2 (6) 4 (7) 5 (8) 4 6 8 12 15 20 30 — 220 3/10 (1/2) 6/10 (1-1/8) 1 1-1/4 (1-6/10) (2-1/4) 2 2-1/2 (3-2/10) (4-1/2) 3-2/10 4 (5-6/10) (6-1/4) 4-1/2 (7-1/2) 4 6 8 12 15 20 30 — 230 3/10 (1/2) 6/10 (1) 8/10 1-1/4 (1-6/10) (2) 1-8/10 2-1/2 (3-2/10) (4) 3-2/10 (5) 3-1/2 (6-1/4) 4-1/2 (7-1/2) 4 6 8 10 15 20 30 — 240 3/10 (1/2) 6/10 (1) 8/10 (1-1/2) 1-1/4 (2) 1-8/10 (3) 2-1/4 (4) 3 (5) 3-1/2 (6-1/4) 4 (7) 3-1/2 5 7 10 15 20 30 — 277 1/4 (4/10) 1/2 (8/10) 8/10 (1-1/4) 1 1-6/10 (1-8/10) (2-1/2) 2 (3-1/2) 2-1/2 (4-1/2) 3-2/10 (5) 3-1/2 (6-1/4) 5 (9) 5 6 9 12 15 25 — 380 3/16 (3/10) 3/10 (6/10) 1/2 (8/10) 3/4 (1-1/4) 1-1/8 1-1/2 (1-8/10) (2-1/2) 1-8/10 2-1/4 (3-2/10) (3-1/2) 2-1/2 (4-1/2) 3-1/2 (6-1/4) 5-6/10 (9) 4-1/2 6-1/4 9 15 20 25 400 3/16 (3/10) 3/10 (6/10) 1/2 (8/10) 3/4 (1-1/4) 1-1/8 1-1/2 (1-8/10) (2-1/2) 1-8/10 (3) 2-1/4 (3-1/2) 2-1/2 (4) 3-1/2 (6-1/4) 5-6/10 (9) 4-1/2 6-1/4 9 12 15 20 416 15/100 3/10 (3/10) (6/10) 1/2 (8/10) 6/10 (1-1/8) 1 1-4/10 (1-8/10) (2-1/4) 1-8/10 (3) 2 (3-1/2) 2-1/2 (4) 3-1/2 (6) 5 (9) 4 6 8 12 15 20 440 15/100 3/10 (1/4) (1/2) 1/2 (8/10) 6/10 (1-1/8) 1 1-1/4 (1-6/10) (2-1/4) 1-6/10 2 2-1/4 (2-8/10) (3-2/10) (3-1/2) 3-2/10 (5) 5 (8) 4 6 8 12 15 20 460 15/100 3/10 (1/4) (1/2) 4/10 (8/10) 6/10 (1) 8/10 (1-1/2) 1-1/4 (2) 1-6/10 (2-1/2) 1-8/10 2-1/4 3-2/10 (3-2/10) (3-2/10) (5) 4-1/2 (8) 3-1/2 6 8 12 15 20 480 15/100 3/10 (1/4) (1/2) 4/10 (3/4) 6/10 (1) 8/10 (1-1/2) 1-1/4 (2) 1-1/2 (2-1/2) 1-8/10 (3) 2 (3-1/2) 3 (5) 4-1/2 (7-1/2) 3-1/2 5 7 10 15 20 550 1/8 (2/10) 1/4 (4/10) 4/10 (6/10) 1/2 (8/10) 8/10 (1-1/4) 1 1-1/4 (1-8/10) (2-1/4) 1-6/10 (2-1/2) 1-8/10 (3) 2-1/2 (4-1/2) 4 (6-1/4) 5 4-1/2 6 9 15 15 575 1/8 (2/10) 1/4 (4/10) 3/10 (6/10) 1/2 (8/10) 3/4 (1-1/4) 1 1-1/4 (1-6/10) (2) 1-1/2 (2-1/2) 1-8/10 (3) 2-1/2 (4) 3 (6-1/4) 5 4-1/2 6 9 15 15 600 1/8 (2/10) 2/10 (4/10) 3/10 (6/10) 1/2 (8/10) 3/4 (1-1/4) 8/10 1-1/4 (1-6/10) (2) 1-1/2 (2-1/2) 1-6/10 2-1/4 (2-8/10) (4) 3-1/2 (6-1/4) 5 4 6 9 15 15 2-1/4 (4) Note: If the rated primary current is less than 2 amperes, the maximum rating of the overcurrent device is 300% for power circuits, shown above, or 500% for control circuits, shown above (in brackets). If the rated primary current is 2 amperes or more, the maximum rating of the overcurrent device is 250%. All figures assume secondary overcurrent protection per NEC/UL. References: NEC 430-72 (c) exception 2, 450-3 (b) 1 & 2, UL 508 32.7, UL 845 11.16 and 11.17. Table 9-104. Maximum Acceptable Rating of Secondary Overcurrent Protection Secondary VA Rating Voltage 25 50 12 24 75 100 150 200 250 300 350 500 750 1000 1500 2000 3000 5000 3-1/2 1-6/10 7 3-2/10 10 5 15 6-1/4 20 10 30 12 — 15 — 20 — 20 — 30 — — — — — — — — — — — — 90 95 100 4/10 4/10 4/10 8/10 8/10 8/10 1-1/4 1-1/4 1-1/4 1-8/10 1-6/10 1-6/10 2-1/2 2-1/2 2-1/2 3-1/2 3-1/2 3-2/10 4-1/2 4 4 5 5 5 6-1/4 6 5-6/10 9 8 8 12 12 12 15 15 15 30 20 20 30 30 30 — — — — — — 110 115 120 3/10 3/10 3/10 3/4 6/10 6/10 1-1/8 1 1 1-1/2 1-4/10 1-1/4 2-1/4 2 2 3 2-8/10 2-1/2 3-1/2 3-1/2 3-2/10 4-1/2 4 4 5 5 4-1/2 7-1/2 7 6-1/4 10 10 10 15 15 15 20 20 20 30 30 20 — — — — — — 220 230 240 15/100 15/100 15/100 3/10 3/10 3/10 1/2 1/2 1/2 3/4 6/10 6/10 1-1/8 1 1 1-1/2 1-4/10 1-1/4 1-8/10 1-8/10 1-6/10 2-1/4 2 2 2-1/2 2-1/2 2-1/2 3-1/2 3-1/2 3-2/10 5-6/10 5 5 7 7 7 9 8 8 15 15 12 20 20 20 30 30 30 Note: If the rated secondary current is less than 9 amperes, the maximum rating of the overcurrent device is 167%; 9 amperes or more, the maximum rating of the overcurrent device is 125%. If 125% does not correspond to a standard fuse rating, the next highest standard rating may be used. References: NEC 430-72 (c) exception 2, 450-3 (b) 1 & 2, UL 508 32.7, UL 845 11.16 and 11.17. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Industrial Control Transformers 9-91 November 2003 Types MTA, MTC and AP Vol. 1, Ref. No. [0391] Wiring Diagrams Type MTA and MTC Control Transformers Table 9-107. Wiring for Diagram 3 Table 9-105. Wiring for Diagram 1 Volts Connect Lines A B 460 230 — — H2 to H3 H1 to H3 and H2 to H4 115 — — H1 H3 H2 Type AP Control Transformers Volts Connect Table 9-109. Wiring for Diagram 5 Lines A B H1-H4 H1-H4 460 230 — — H2 to H3 H1 to H3 and H2 to H4 X1-X2 230 115 — — X2 to X3 X1 to X3 and X2 to X4 Volts Connect Lines — — H2 to H3 H1 to H3 and H2 to H4 H1-H4 H1-H4 — — X2 to X3 X1 to X3 and X2 to X4 X1-X4 X1-X4 A B H1-H4 H1-H4 480 240 X1-X4 X1-X4 240 115 H4 X2 H1 H3 H2 H4 H1 H3 H2 H4 X4 X2 X3 X1 X4 X2 X3 X1 X1 Figure 9-3. Diagram 1 Figure 9-7. Diagram 5 Figure 9-5. Diagram 3 Table 9-106. Wiring for Diagram 2 Volts A Connect Lines Volts B 575 460 230 — 416 380 — 208 H2 to H3 H2 to H3 H1 to H3 and H2 to H4 H1 to H3 and H2 to H5 H1-H5 H1-H4 H1-H4 H1-H5 115 95 115 95 — — X1-X3 X1-X2 H1 X3 Table 9-108. Wiring for Diagram 4 H3 H2 X2 H4 Connect Lines 115 — H1-H2 24 — X1-X2 A B 115 12 H1 H2 X2 X1 H5 X1 Figure 9-6. Diagram 4 Figure 9-4. Diagram 2 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Industrial Control Transformers 9-92 November 2003 Type MTA Vol. 1, Ref. No. [0392] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-110. Type MTA VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Frame Wiring Style Diagram Number Price U.S. 230/460 Volts to 115 Volts, 60 Hz 50 9 (Use Type MTC – C0050C2A) 75 100 3-3/16 3-3/16 3-3/4 3-3/4 3-3/4 4 3 4 80 80 95 95 95 102 1.4 1.8 FR1510 FR1512 1 1 C0075A2F C0100A2F 74.00 76.50 150 200 250 3-3/16 3-13/16 3-13/16 3-3/4 4-1/2 4-1/2 4-3/4 4-1/2 5 6 7 8 80 96 96 95 114 114 95 114 127 2.7 3.2 3.6 FR1520 FR1714 FR1717 1 1 1 C0150A2F C0200A2F C0250A2F 88.00 110.00 131.00 300 350 500 3-13/16 3-13/16 4-3/8 4-1/2 4-1/2 5-1/4 5-1/2 6 5-5/8 10 12 15 96 96 111 114 114 133 139 152 143 4.5 5.4 6.8 FR1723 FR1727 FR1923 1 1 1 C0300A2F C0350A2F C0500A2F 143.00 154.00 189.00 750 1000 1500 4-3/8 5-1/4 6 5-1/4 6-1/8 6-7/8 6-1/8 6-3/4 7-1/2 19 19 27 111 133 152 133 155 174 155 171 190 8.6 8.6 12.3 FR1931 FRC613 FRC614 1 1 1 C0750A2F C1000A2F C1500A2F 249.00 396.00 521.00 2000 3000 5000 5-7/8 6-1/2 7-5/8 6-7/8 8-3/16 8-15/16 8-1/2 8-3/4 10-1/4 36 52 79 149 165 193 174 207 227 215 222 260 16.3 23.6 35.8 FRC827 FRC828 FRC829 1 1 1 C2000A2F C3000A2F C5000A2F 624.00 835.00 1,320.00 230/460 Volts to 115/230 Volts, 60 Hz 50 75 100 2-19/32 3-3/16 3-3/16 3 3-3/4 3-3/4 3-1/4 3-3/4 4 2 3 4 65 80 80 76 95 95 82 95 102 .9 1.4 1.8 FR1310 FR1510 FR1512 3 3 3 C0050A2G C0075A2G C0100A2G 94.00 102.00 110.00 150 200 250 3-3/16 3-13/16 3-13/16 3-3/4 4-1/2 4-1/2 4-3/4 4-1/2 5 6 7 8 80 96 96 95 114 114 95 114 127 2.7 3.2 3.6 FR1520 FR1714 FR1717 3 3 3 C0150A2G C0200A2G C0250A2G 121.00 137.00 154.00 300 350 500 3-13/16 3-13/16 4-3/8 4-1/2 4-1/2 5-1/4 6 6 6-1/4 10 12 15 96 96 111 114 114 133 152 152 158 4.5 5.4 6.8 FR1727 FR1727 FR1930 3 3 3 C0300A2G C0350A2G C0500A2G 165.00 177.00 210.00 750 1000 1500 5-1/4 5-1/4 6 6-1/8 6-1/8 6-7/8 6-3/4 6-3/4 7-1/2 19 19 27 133 133 152 155 155 174 171 171 190 8.6 8.6 12.3 FRC613 FRC613 FRC614 3 3 3 C0750A2G C1000A2G C1500A2G 269.00 409.00 542.00 2000 3000 5000 5-7/8 6-1/2 5-5/8 6-7/8 8-3/16 8-15/16 8-1/2 8-3/4 10-1/4 36 52 79 149 165 193 174 207 227 215 222 260 16.3 23.6 35.8 FRC827 FRC828 FRC829 3 3 3 C2000A2G C3000A2G C5000A2G 650.00 865.00 1,390.00 See Page 9-91 for Wiring Diagrams. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Industrial Control Transformers 9-93 November 2003 Type MTA Vol. 1, Ref. No. [0393] Table 9-111. Type MTA VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Frame Wiring Style Diagram Number Price U.S. 230/460/575 Volts to 115/95 Volts, 50/60 Hz 50 75 100 2-19/32 3-3/16 3-3/16 3 3-3/4 3-3/4 3-3/4 4 4 3/4 2 4 5 98 80 80 76 95 95 95 102 120 1.5 1.8 2.7 FR1314 FR1512 FR1517 2A 2A 2A C0050A3C C0075A3C C0100A3C 94. 102. 110. 150 200 250 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4-1/2 5 5-1/2 7 8 10 96 96 96 114 114 114 114 127 139 3.2 3.6 4.5 FR1714 FR1717 FR1723 2A 2A 2A C0150A3C C0200A3C C0250A3C 121. 137. 169. 300 350 500 3-13/16 4-3/8 4-3/8 4-1/2 5-1/4 5-1/4 6 5-5/8 6-1/8 12 14 17 96 111 111 114 133 133 152 143 155 5.4 6.8 8.6 FR1730 FR1923 FR1931 2A 2A 2A C0300A3C C0350A3C C0500A3C 176. 194. 246. 4-3/8 6 5-7/8 5-1/4 6-7/8 6-7/8 7-3/4 7-1/2 8-1/2 27 24 34 111 152 149 133 174 174 196 190 215 12.3 10.9 15.4 FR1943 FRC614 FRC827 2A 2A 2A C0750A3C C1000A3C C1500A3C 280. 568. 753. 3-3/4 4-1/8 4-1/2 2 5 7 65 80 96 76 95 114 82 104 114 .9 2.3 3.2 FR1310 FR1513 FR1714 4B 4B 4B C0050A3B C0100A3B C0200A3B 97. 116. 137. 750 1000 1500 115 Volts to 24 Volts, 50/60 Hz 50 100 200 2-19/32 3-3/16 3-13/16 3 3-3/4 4-1/2 208/380/416 Volts to 115/95 Volts, 50/60 Hz 50 100 150 200 2-19/32 3-3/16 3-13/16 3-13/16 3 3-3/4 4-1/2 4-1/2 3-3/4 4-3/4 4-1/2 5 3 5 7 8 98 80 96 96 76 95 114 114 95 120 114 127 1.5 2.3 3.2 3.6 FR1314 FR1516 FR1714 FR1717 2B 2B 2B 2B C0050A3D C0100A3D C0150A3D C0200A3D 94. 110. 121. 137. 250 300 500 3-13/16 3-13/16 4-3/8 4-1/2 4-1/2 5-1/4 5-1/2 6 6-1/8 10 13 18 96 96 111 114 114 133 139 152 155 4.5 5.4 8.6 FR1723 FR1730 FR1931 2B 2B 2B C0250A3D C0300A3D C0500A3D 169. 176. 246. 4-3/8 6 5-7/8 5-1/4 6-7/8 6-7/8 7-3/4 7-1/2 8-1/2 27 25 33 111 152 149 133 174 174 196 190 215 12.3 10.9 15.4 FR1943 FRC614 FRC827 2B 2B 2B C0750A3D C1000A3D C1500A3D 280. 555. 753. 750 1000 1500 See Page 9-91 for Wiring Diagrams. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Industrial Control Transformers 9-94 November 2003 Type MTC Type MTC Vol. 1, Ref. No. [0394] Features, Benefits and Functions Product Specifications ■ Cutler-Hammer standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. ■ ■ ■ ■ Type MTC Transformers 9 Product Description ■ Varnish impregnated core and coil design. ■ Suitable for indoor applications. Application Description Transformers provide stepped down voltages to machine tool control devices enabling control circuits to be isolated from all power and lighting circuits. This allows the use of grounded or ungrounded circuits that are independent of the power or lighting grounds; greater safety is afforded the operator. The control transformer line is particularly adaptable on applications where compact construction is demanded. The MTC line is similar to the MTA line except it provides increased regulation. ■ ■ ■ ■ ■ Designed specifically for loads requiring extremely good regulation — 10% – 200% better regulation than Type MTA. UL recognized component for units rated 1000 VA and below. CSA certified for units rated 1000 VA and below. 50/60 Hz operation standard. 100% tested to verify product quality. Each unit must pass rigid tests for turns ratio, insulation, continuity, and over potential. Performance equals or exceeds requirements of ANSI/NEMA ST-1. Regulation exceeds ANSI/NEMA requirements for all ratings. 50 – 5000 VA ratings. 55ºC rise, 105ºC insulation system. Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. Frequency Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-112. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Series-Multiple Windings Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications Please refer to Page 9-122. The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Industrial Control Transformers 9-95 November 2003 Type MTC Vol. 1, Ref. No. [0395] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-113. Type MTC VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Frame Wiring Style Diagram Number Price U.S. 240/480 Volts to 120 Volts, 60 Hz 230/460 Volts to 115 Volts, 50/60 Hz 220/440 Volts to 110 Volts, 50/60 Hz 50 75 100 2-19/32 2-19/32 2-7/8 3 3 3-3/8 3-3/4 3-3/4 4 2 3 3 66 66 73 76 76 86 95 95 102 .9 1.4 1.4 FR1310 FR1314 FR1413 1 1 1 C0050C2A C0075C2A C0100C2A 67.00 78.50 84.00 150 200 250 3-3/16 3-13/16 3-13/16 3-3/4 4-1/2 4-1/2 4-3/4 4-1/2 5 6 7 8 81 97 97 95 114 114 121 114 127 2.7 3.2 3.6 FR1517 FR1714 FR1717 1 1 1 C0150C2A C0200C2A C0250C2A 100.00 116.00 144.00 300 350 500 3-13/16 3-13/16 4-3/8 4-1/2 4-1/2 5-1/4 5-3/8 6 6-1/8 10 11 20 97 97 111 114 114 133 137 152 156 4.5 5.0 9.1 FR1722 FR1726 FR1931 1 1 1 C0300C2A C0350C2A C0500C2A 154.00 169.00 206.00 750 1000 1500 4-3/8 5-7/16 6-1/8 5-1/4 6-3/8 6-7/8 7-3/4 7-1/2 8-3/8 28 34 35 111 138 156 133 162 175 197 191 213 12.7 15.4 15.9 FR1934 FR2236 FRC822 1 1 1 C0750C2A C1000C2A C1500C2A 272.00 402.00 564.00 2000 3000 5000 6 7-3/8 7-7/8 6-3/4 8-7/16 8-11/16 8-1/2 8-3/4 11 38 53 82 152 187 200 171 214 221 216 222 279 17.3 24.1 37.2 FRC823 FRC824 FRC825 1 1 1 C2000C2A C3000C2A C5000C2A 676.00 934.00 1,445.00 See Page 9-91 for Wiring Diagrams. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. Table 9-114. Type MTC with Integrally Mounted 30 Amperes, 600 volt Class with 2-Pole Primary Fuse Block for Rejection Type Fuses (Fuses Not Included) VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Frame Style Wiring Diagram Number Price U.S. 240/480 Volts to 120 Volts, 60 Hz 230/460 Volts to 115 Volts, 50/60 Hz 220/440 Volts to 110 Volts, 50/60 Hz 50 75 100 150 3-7/8 3-7/8 4-5/32 4-15/32 3 3 3-3/8 3-3/4 3-3/4 3-3/4 4 4-3/4 2.2 3.2 3.2 6.2 98 98 106 114 76 76 86 95 83 95 102 121 1.0 1.5 1.5 2.8 FR1310 FR1314 FR1413 FR1517 1 1 1 1 C0050C2AFB C0075C2AFB C0100C2AFB C0150C2AFB 88.00 101.00 106.00 123.00 200 250 300 5-3/32 5-3/32 5-3/32 4-1/2 4-1/2 4-1/2 4-1/2 5 5-3/8 7.2 8.2 10.2 129 129 129 114 114 114 114 127 137 3.3 3.7 4.7 FR1714 FR1717 FR1722 1 1 1 C0200C2AFB C0250C2AFB C0300C2AFB 138.00 166.00 176.00 350 500 750 5-3/32 5-21/32 5-21/32 4-1/2 5-1/4 5-1/4 6 6-1/8 7-3/4 11.2 20.2 28.2 129 144 144 114 133 133 152 156 197 5.1 9.2 12.8 FR1726 FR1931 FR1934 1 1 1 C0350C2AFB C0500C2AFB C0750C2AFB 191.00 227.00 294.00 1000 1500 2000 6-23/32 7-13/32 7-9/32 6-3/8 6-7/8 6-3/4 7-1/2 8-3/8 8-1/2 34.2 35.2 38.2 171 188 185 162 175 171 191 213 216 15.5 16.0 17.4 FR2236 FRC822 FRC823 1 1 1 C1000C2AFB C1500C2AFB C2000C2AFB 424.00 585.00 697.00 See Page 9-91 for Wiring Diagrams. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Industrial Control Transformers 9-96 November 2003 Type MTE Type MTE Vol. 1, Ref. No. [0396] Features, Benefits and Functions ■ ■ ■ ■ ■ ■ Type MTE Transformers 9 ■ ■ Product Description ■ ■ Epoxy-encapsulated coils. ■ Application Description ■ Transformers provide stepped down voltages to machine tool control devices enabling control circuits to be isolated from all power and lighting circuits. This allows the use of grounded or ungrounded circuits that are independent of the power or lighting grounds; greater safety is afforded the operator. The control transformer line is particularly adaptable on applications where compact construction is demanded. ■ Note: The MTG, “open core-coil design” has been superseded by the epoxyencapsulated core-coil design MTE with no change to dimensions or functionality. ■ ■ Finger-Safe Terminal Covers (Optional) ■ ■ UL listed. CSA certified. Epoxy encapsulated. Laminations of high quality silicon steel to minimize core losses and optimize performance. Copper magnet wire for high quality, efficient operation. Secondary fuse clips where applicable. Optional primary fusing. Molded in terminals. 50/60 Hz operation. 55°C rise, 105ºC insulation system. Performance meets/exceeds requirements of ANSI/NEMA ST-1. Regulation exceeds ANSI/NEMA requirements for all ratings. 25 – 1500 VA ratings. Molded-in terminals for maximum durability. Fits CE marked designs 50 – 750 VA. Fits MTE designs. 25 – 750 VA. Table 9-116. Finger-Safe Terminal Covers Description Catalog Price Number U.S. $ 4 Terminal Transformers 6 Terminal Transformers FSK4 FSK6 24. 25. Finger-Safe Terminal Covers — FSK4 Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Options and Accessories Finger-Safe Terminal Covers — FSK6 Primary Fuse Kit Finger-Safe Primary Fuse Block Covers The primary fuse kit includes a 2-pole class CC fuse block, instructions, and all associated mounting and wiring hardware. Fuses are not included. When installed, the primary fuse kit will add a maximum of 11/16 inch to the transformer depth and 1-15/16 inches to the transformer height. ■ Fits 2-pole primary fuse blocks on MTE designs. Table 9-117. Finger-Safe Primary Fuse Block Covers Description Catalog Price Number U.S. $ Primary Fuse Block Covers FSKFB 38. Table 9-115. Primary Fuse Kit Description Catalog Price Number U.S. $ Primary Fuse Kit PFK1 26. Finger-Safe Primary Fuse Block Covers Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Industrial Control Transformers 9-97 November 2003 Type MTE Vol. 1, Ref. No. [0397] Product Specifications Wiring Diagrams Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-118. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Figure 9-8. Diagram 1 Figure 9-11. Diagram 4 9 Series-Multiple Windings Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Technical Data and Specifications Figure 9-9. Diagram 2 Figure 9-12. Diagram 5 Figure 9-10. Diagram 3 Please refer to Page 9-122. Figure 9-13. Diagram 6 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9-98 Transformers Industrial Control Transformers November 2003 Type MTE Vol. 1, Ref. No. [0398] Wiring Diagrams H3 H2 H4 X4 X2 X3 X1 0V 220,230,240 V 380,400,416 V 440,460,480 V H5 110,115,120 V H1 H4 23/24/25 H1 H3 H2 H4 H3 0V H1 H3 H2 H4 H2 550,575,600 V 480 V X4 X2 X3 X1 Figure 9-14. Diagram 7 H1 240 V X3 X2 X1 X4 X2 X3 X1 Figure 9-21. Diagram 14 120 V 240 V H6 0V 208 V H5 230 V H4 230 V 24 V 115 V H2 0V 600 V 575 V 550 V H3 400 V Figure 9-18. Diagram 11 H1 H2 575 V H1 460 V 9 Figure 9-15. Diagram 8 X4 H6 0V 208 V H5 X3 X2 115 V 115 V 0V 0V X4 X2 H4 H2 Figure 9-16. Diagram 9 24 V 23 V 22 V H3 230 V 575 V H2 400 V H1 420 V 400 V 380 V X1 X1 Figure 9-19. Diagram 12 H1 X2 Figure 9-22. Diagram 15 460 V X2 24 V 23 V 22 V X3 X1 Figure 9-23. Diagram 16 X1 Figure 9-20. Diagram 13 Figure 9-17. Diagram 10 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Industrial Control Transformers 9-99 November 2003 Type MTE Vol. 1, Ref. No. [0399] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-119. Type MTE — Product Selection VA Dimensions (Inches) Height Width Weight Lbs. Depth Dimensions (mm) Height Width Depth Weight kg Wiring Diagram Style Number Price U.S. $ Primary: 240 x 480, 230 x 460, 220 x 440 with Jumpers Secondary: 120/115/110 with Fuse Clips for 13/32 x 1-1/2 Fuses 25 50 75 100 2-9/16 2-9/16 2-9/16 2-7/8 3 3 3 3-3/8 2-1/2 3 3-1/2 3-3/8 1.7 2.6 3.5 4.2 65 65 65 73 76 76 76 86 64 76 89 86 .8 1.2 1.6 1.9 1 1 1 1 C0025E2A C0050E2A C0075E2A C0100E2A 72.00 53.50 64.00 69.00 150 200 250 3-3/16 3-13/16 3-13/16 3-3/4 4-1/2 4-1/2 4 4 4-3/8 6.7 8.5 10.0 81 97 97 95 114 114 102 102 111 3.0 3.9 4.5 1 1 1 C0150E2A C0200E2A C0250E2A 82.00 101.00 117.00 300 350 500 3-13/16 3-13/16 4-3/4 4-1/2 4-1/2 5-1/4 4-3/4 5-1/4 5-1/2 11.3 13.6 19.2 97 97 121 114 114 133 121 133 140 5.1 6.2 8.7 1 1 1 C0300E2A C0350E2A C0500E2A 126.00 138.00 173.00 750 1000 1500 4-3/4 5-11/16 6-3/8 5-1/4 6-3/4 7-1/2 7 6-7/16 7-3/8 28.1 29.5 40.0 121 144 162 133 171 191 178 164 187 12.8 13.4 18.1 1 1 1 C0750E2A C1000E2A C1500E2A 238.00 634.00 851.00 Primary: 240 x 480 with Jumpers Secondary: 24 with Fuse Clips for 13/32 x 1-1/2 Fuses (through 500 VA) 50 75 100 150 2-9/16 2-9/16 2-7/8 3-3/16 3 3 3-3/8 3-3/4 3 3-1/2 3-3/8 4 2.7 3.5 4.2 6.7 65 65 73 81 76 76 86 95 76 89 86 102 1.2 1.6 1.9 3.0 2 2 2 2 C0050E2B C0075E2B C0100E2B C0150E2B 62.00 73.00 82.00 107.00 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4 4-3/8 4-3/4 8.5 10.1 11.4 97 97 97 114 114 114 102 111 121 3.9 4.6 5.2 2 2 2 C0200E2B C0250E2B C0300E2B 129.00 147.00 161.00 350 500 750 3-13/16 4-3/4 4-3/4 4-1/2 5-1/4 5-1/4 5-1/4 5-5/8 7 13.4 17.5 28.1 97 121 121 114 133 133 133 143 178 6.1 7.9 12.8 2 2 2 C0350E2B C0500E2B C0750E2B 174.00 203.00 263.00 Primary: 120 x 240 with Jumpers Secondary: 24 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 2-9/16 2-9/16 2-7/8 3 3 3-3/8 3 3-1/2 3-3/8 2.6 3.6 4.4 65 65 73 76 76 86 76 89 56 1.2 1.6 2.0 3 3 3 C0050E1B C0075E1B C0100E1B 62.00 72.50 82.00 150 200 250 3-3/16 3-13/16 3-13/16 3-3/4 4-1/2 4-1/2 4 4 4-3/8 6.7 8.3 10.1 81 97 97 95 114 114 102 102 111 3.0 3.8 4.6 3 3 3 C0150E1B C0200E1B C0250E1B 107.00 129.00 147.00 300 350 500 3-13/16 3-13/16 4-3/4 4-1/2 4-1/2 5-1/4 4-3/4 5-1/4 5-5/8 11.2 13.2 17.5 97 97 121 114 114 133 121 133 143 5.1 6.0 7.9 3 3 3 C0300E1B C0350E1B C0500E1B 161.00 174.00 203.00 Primary: 208/277 Secondary: 120 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 150 2-9/16 2-9/16 2-7/8 3-3/16 3 3 3-3/8 3-3/4 3 3-1/2 3-3/8 4 2.9 3.8 4.5 6.9 65 65 73 81 76 76 86 95 76 89 86 102 1.3 1.7 2.0 3.1 4 4 4 4 C0050E3A C0075E3A C0100E3A C0150E3A 60.50 71.50 81.50 104.00 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4 4-3/8 4-3/4 8.7 10.2 11.4 97 97 97 114 114 114 102 111 121 3.9 4.6 5.2 4 4 4 C0200E3A C0250E3A C0300E3A 127.00 144.00 158.00 350 500 750 3-13/16 4-3/4 4-3/4 4-1/2 5-1/4 5-1/4 5-1/4 5-3/8 7 13.7 17.2 25.7 97 121 121 114 133 133 133 136 178 6.2 7.8 11.7 4 4 4 C0350E3A C0500E3A C0750E3A 171.00 196.00 263.00 See Page 9-97 for Wiring Diagrams. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Industrial Control Transformers 9-100 November 2003 Type MTE Vol. 1, Ref. No. [0400] Table 9-120. Type MTE — Product Selection VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Wiring Diagram Style Number Price U.S. $ Primary: 240 x 480 with Jumpers Secondary: 120 x 240 with Jumpers, Secondary Fuse Clips not Applicable 50 75 100 150 2-9/16 2-9/16 2-7/8 3-3/16 3 3 3-3/8 3-3/4 3 3-1/2 3-3/8 4 2.6 3.5 4.2 6.7 65 65 73 81 76 76 86 95 76 89 86 102 1.2 1.6 1.9 3.1 11 11 11 11 C0050E2CXX C0075E2CXX C0100E2CXX C0150E2CXX 68. 75. 82. 107. 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4 4-3/8 4-7/8 8.5 10.0 11.8 97 97 97 114 114 114 102 111 124 3.9 4.6 5.4 11 11 11 C0200E2CXX C0250E2CXX C0300E2CXX 129. 144. 158. 350 500 750 3-13/16 4-3/4 4-3/4 4-1/2 5-1/4 5-1/4 5-1/4 5-1/4 7 13.6 17.5 26.4 97 121 121 114 133 133 133 133 178 6.2 8.0 12.0 11 11 11 C0350E2CXX C0500E2CXX C0750E2CXX 171. 196. 263. Primary: 550/575/600 Secondary: 110/115/120 with for 13/32 x 1-1/2 Fuses 9 50 75 100 150 2-9/16 2-9/16 2-7/8 3-3/16 3 3 3-3/8 3-3/4 3 3-1/2 3-3/8 4 2.7 3.6 4.2 6.8 65 65 73 81 76 76 86 95 76 89 86 102 1.2 1.6 1.9 3.1 10 10 10 10 C0050E4C C0075E4C C0100E4C C0150E4C 85. 92. 101. 117. 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4 4-3/8 4-3/4 8.4 10.0 11.3 97 97 97 114 114 114 102 111 121 3.8 4.6 5.1 10 10 10 C0200E4C C0250E4C C0300E4C 129. 158. 171. 350 500 750 3-13/16 4-3/4 4-3/4 4-1/2 5-1/4 5-1/4 5-1/4 5-3/8 7 13.6 16.8 25.7 97 121 121 114 133 133 133 137 178 6.2 7.6 11.7 10 10 10 C0350E4C C0500E4C C0750E4C 186. 200. 267. Primary: 380/400/415 Secondary: 22/23/24 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 2-9/16 2-9/16 2-7/8 3 3 3-3/8 3 3-1/2 3-3/8 2.5 3.5 4.0 65 65 73 76 76 86 76 89 86 1.1 1.6 1.8 13 13 13 C0050E4H C0075E4H C0100E4H 92. 98. 107. 150 200 250 3-3/16 3-13/16 3-13/16 3-3/4 4-1/2 4-1/2 4 4 4-3/8 6.5 8.2 10.0 81 97 97 95 114 114 102 102 111 3.0 3.7 4.5 13 13 13 C0150E4H C0200E4H C0250E4H 124. 134. 163. 300 350 500 3-13/16 3-13/16 4-3/4 4-1/2 4-1/2 5-1/4 4-3/4 5-1/4 5-1/2 11.0 13.6 17.7 97 97 121 114 114 133 121 133 140 5.0 6.2 8.0 13 13 13 C0300E4H C0350E4H C0500E4H 178. 192. 208. Primary: 550/575/600 Secondary: 22/23/24 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 150 2-9/16 2-9/16 2-7/8 3-3/16 3 3 3-3/8 3-3/4 3 3-1/2 3 3/8 4 2.5 3.5 4.0 6.5 65 65 73 81 76 76 86 95 76 89 86 102 1.1 1.6 1.8 3.0 12 12 12 12 C0050E4W C0075E4W C0100E4W C0150E4W 92. 98. 107. 117. 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4 4-3/8 4-3/4 8.2 10.0 11.0 97 97 97 114 114 114 102 111 121 3.7 4.5 5.0 12 12 12 C0200E4W C0250E4W C0300E4W 131. 159. 173. 350 500 750 3-13/16 4-3/4 4-1/2 4-1/2 5-1/4 5-1/4 5-1/4 5-1/2 7-3//8 13.6 17.7 28.0 97 121 114 114 133 133 133 140 187 6.2 8.0 12.7 12 12 12 C0350E4W C0500E4W C0750E4WXX 188. 203. 270. See Page 9-98 for Wiring Diagrams. Secondary fuse clips are not available on this catalog number. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Industrial Control Transformers 9-101 November 2003 Type MTE Vol. 1, Ref. No. [0401] Table 9-121. Types MTE — Product Selection VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Wiring Diagram Style Number Price U.S. $ Primary: 230/460/575 Secondary: 115/95 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 150 2-9/16 2-7/8 2-7/8 3-3/16 3 3-3/8 3-3/8 3-3/4 3 3-3/8 3-7/8 4-1/4 3.5 4.5 6.0 7.7 65 73 73 81 76 86 86 95 76 86 98 108 1.6 2.0 2.7 3.5 5 5 5 5 C0050E3C C0075E3C C0100E3C C0150E3C 85.50 92.50 102.00 118.00 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4-1/4 4-3/4 5-1/8 9.0 9.7 11.7 97 97 97 114 114 114 108 121 130 4.1 4.4 5.3 5 5 5 C0200E3C C0250E3C C0300E3C 131.00 161.00 174.00 350 500 750 4-3/4 4-3/4 4-3/4 5-1/4 5-1/4 5-1/4 5 5-5/8 7 16.5 21.5 28.0 121 121 121 133 133 133 127 143 178 7.5 9.8 12.7 5 5 5 C0350E3C C0500E3C C0750E3C 189.00 203.00 271.00 Primary: 380/400/415 Secondary: 110 x 220 with Jumpers; Fuse Clips not Applicable 50 75 100 150 2-9/16 2-9/16 2-7/8 3-3/16 3 3 3-3/8 3-3/4 3 3-1/2 3-9/16 4 3.0 4.0 5.2 7.0 65 65 73 81 76 76 86 95 76 89 90 102 1.4 1.8 2.4 3.2 6 6 6 6 C0050E4D C0075E4D C0100E4D C0150E4D 85.00 92.00 101.00 117.00 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4 4-3/8 4-3/4 8.7 10.2 11.0 97 97 97 114 114 114 102 111 121 3.9 4.6 5.0 6 6 6 C0200E4D C0250E4D C0300E4D 129.00 158.00 171.00 350 500 750 3-13/16 4-3/4 4-3/4 4-1/2 5-1/4 5-1/4 5-1/4 5-3/8 7 13.0 20.0 28.0 97 121 121 114 133 133 133 136 178 5.9 9.1 12.7 6 6 6 C0350E4D C0500E4D C0750E4D 186.00 200.00 267.00 Primary: 200/220/440, 208/230/460, 240/480 Secondary: 23/110, 24/115, 25/120 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 2-9/16 2-7/8 3-3/16 3 3-3/8 3-3/4 3-1/4 3-1/2 5-5/8 3.4 4.8 5.9 65 73 81 76 86 95 83 89 143 1.5 2.2 2.7 7 7 7 C0050E5E C0075E5E C0100E5E 76.50 83.00 92.50 150 200 250 3-3/16 3-13/16 3-13/16 3-3/4 4-1/2 4-1/2 4-3/8 4-1/2 5-1/4 7.9 10.6 13.9 81 97 97 95 114 114 111 114 133 3.6 4.8 6.3 7 7 7 C0150E5E C0200E5E C0250E5E 117.00 139.00 161.00 300 350 500 4-3/4 4-3/4 4-3/4 5-1/4 5-1/4 5-1/4 5-1/8 5-3/8 6-7/8 15.5 16.8 23.4 121 121 121 133 133 133 130 136 175 7.0 7.6 10.6 7 7 7 C0300E5E C0350E5E C0500E5E 177.00 184.00 222.00 Universal Design (MTE Epoxy Encapsulated) Primary: 240/416/480/600, 230/400/460/575, 220/380/440/550, 208/500 Secondary: 99/120/130, 95/115/125, 91/110/120, 85/100/110 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 100 150 250 2-7/8 3-3/16 3-13/16 3-13/16 3-3/8 3-3/4 4-1/2 4-1/2 4 4-5/8 4-7/16 5-7/8 4.0 6.6 8.8 14.7 73 81 97 97 86 95 114 114 102 117 113 149 1.8 3.0 4.0 6.7 8 8 8 8 C0050E6U C0100E6U C0150E6U C0250E6U 150.00 159.00 165.00 197.00 350 500 750 4-7/16 4-7/16 5-3/4 5-1/4 5-1/4 6-3/4 5-5/8 7 5-11/16 18.6 25.6 30.5 113 113 146 133 133 171 143 178 144 8.4 11.6 13.8 8 8 8 C0350E6U C0500E6U C0750E6U 228.00 287.00 332.00 See Pages 9-97 and 9-98 for Wiring Diagrams. Type MTG Open Core-Coil Universal Design has been superseded by Type MTE Epoxy Encapsulated Universal Design with no changes to form, fit or function. Type MTE Epoxy Encapsulated Universal Design. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Industrial Control Transformers 9-102 November 2003 Type MTE Vol. 1, Ref. No. [0402] Table 9-122. Transformers with Primary Fuse Blocks — Product Selection VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Wiring Diagram Style Number Price U.S. $ Primary: 240 x 480, 230 x 460, 220 x 440 with Jumpers and Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 120/115/110 with Fuse Clips for 13/32 x 1-1/2 Fuses 9 50 75 100 3-15/16 3-15/16 4-1/4 3 3 3-3/8 3 3-1/2 3-3/8 2.8 3.7 4.4 100 100 108 76 76 86 76 89 86 1.3 1.7 2.0 1 1 1 C0050E2AFB C0075E2AFB C0100E2AFB 71.00 82.00 87.00 150 200 250 4-9/16 5-3/16 5-3/16 3-3/4 4-1/2 4-1/2 4 4 4-3/8 6.9 8.7 10.2 116 132 132 95 114 114 102 102 111 3.1 3.9 4.6 1 1 1 C0150E2AFB C0200E2AFB C0250E2AFB 101.00 119.00 136.00 300 350 500 5-3/16 5-3/16 6-1/8 4-1/2 4-1/2 5-1/4 4-3/4 5-1/4 5-1/2 11.5 13.8 19.4 132 132 156 114 114 133 121 133 140 5.2 6.3 8.8 1 1 1 C0300E2AFB C0350E2AFB C0500E2AFB 143.00 156.00 191.00 750 1000 1500 6-1/8 7-1/16 7-3/4 5-1/4 6-3/4 7-1/2 7 6-7/16 7-3/8 28.3 29.7 40.2 156 179 197 133 171 191 178 164 187 12.8 13.4 18.1 1 1 1 C0750E2AFB C1000E2AFB C1500E2AFB 256.00 651.00 868.00 Primary: 240 x 480 with Jumpers and Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 24 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 3-15/16 3-15/16 4-1/4 3 3 3-3/8 3 3-1/2 3-3/8 2.8 3.8 4.4 100 100 108 76 76 86 76 89 86 1.3 1.7 2.1 2 2 2 C0050E2BFB C0075E2BFB C0100E2BFB 80.00 90.50 101.00 150 200 250 4-9/16 5-3/16 5-3/16 3-3/4 4-1/2 4-1/2 4 4 4-3/8 6.9 8.7 10.3 116 132 132 95 114 114 102 102 111 3.1 3.9 4.7 2 2 2 C0150E2BFB C0200E2BFB C0250E2BFB 125.00 147.00 164.00 300 350 500 5-3/16 5-3/16 6-1/8 4-1/2 4-1/2 5-1/4 4-3/4 5-1/4 5-5/8 11.6 13.6 17.7 132 132 156 114 114 133 121 133 143 5.3 6.2 8.0 2 2 2 C0300E2BFB C0350E2BFB C0500E2BFB 179.00 192.00 222.00 Primary: 120 x 240 with Jumpers and Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 24 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 3-15/16 3-15/16 4-1/4 3 3 3-3/8 3 3 1/2 3 3/8 2.8 3.8 4.6 100 100 108 76 76 86 76 89 86 1.3 1.7 2.1 3 3 3 C0050E1BFB C0075E1BFB C0100E1BFB 80.00 90.50 101.00 150 200 250 4-9/16 5-3/16 5-3/16 3-3/4 4-1/2 4-1/2 4 4 4 3/8 6.9 8.5 10.3 116 132 132 95 114 114 102 102 111 3.1 3.9 4.7 3 3 3 C0150E1BFB C0200E1BFB C0250E1BFB 125.00 147.00 164.00 300 350 500 5-3/16 5-3/16 6-1/8 4-1/2 4-1/2 5-1/4 4 3/4 5 1/4 5 5/8 11.4 13.4 17.7 132 132 156 114 114 133 121 133 143 5.2 6.1 8.0 3 3 3 C0300E1BFB C0350E1BFB C0500E1BFB 180.00 192.00 222.00 Primary: 208/277 with Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 120 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 3-15/16 3-15/16 4-1/4 3 3 3-3/8 3 3-1/2 3-3/8 3.1 4.0 4.7 100 100 108 76 76 86 76 89 86 1.4 1.8 2.1 4 4 4 C0050E3AFB C0075E3AFB C0100E3AFB 78.50 90.00 100.00 150 200 250 4-9/16 5-3/16 5-3/16 3-3/4 4-1/2 4-1/2 4 4 4-3/8 7.1 8.9 10.4 116 132 132 95 114 114 102 102 111 3.2 4.0 4.7 4 4 4 C0150E3AFB C0200E3AFB C0250E3AFB 122.00 145.00 162.00 300 350 500 5-3/16 5-3/16 6-1/8 4-1/2 4-1/2 5-1/4 4-3/4 5-1/4 5-3/8 11.6 13.9 17.4 132 132 156 114 114 133 121 133 143 5.3 6.3 7.9 4 4 4 C0300E3AFB C0350E3AFB C0500E3AFB 176.00 188.00 213.00 See Page 9-97 for Wiring Diagrams. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Industrial Control Transformers 9-103 November 2003 Type MTE Vol. 1, Ref. No. [0403] Table 9-123. Transformers with Primary Fuse Blocks — Product Selection VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Wiring Diagram Style Number Price U.S. $ Primary: 550/575/600 with Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 110/115/120 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 150 3-15/16 3-15/16 4-1/4 4-9/16 3 3 3 -3/8 3-3/4 3 3-1/2 3 3/8 4 2.9 3.8 4.4 7.0 100 100 108 116 76 76 86 95 76 89 86 102 1.3 1.7 2.0 3.2 10 10 10 10 C0050E4CFB C0075E4CFB C0100E4CFB C0150E4CFB 103. 110. 119. 135. 200 250 300 5-3/16 5-3/16 5-3/16 4-1/2 4-1/2 4-1/2 4 4 3/8 4 3/4 8.6 10.2 11.5 132 132 132 114 114 114 102 111 121 3.9 4.6 5.2 10 10 10 C0200E4CFB C0250E4CFB C0300E4CFB 147. 176. 188. 350 500 750 5-3/16 6-1/8 6-1/8 4-1/2 5-1/4 5-1/4 5 1/4 5 3/8 7 13.8 17.0 25.9 132 156 156 114 133 133 133 137 178 6.3 7.7 11.8 10 10 10 C0350E4CFB C0500E4CFB C0750E4CFB 204. 218. 285. Primary: 380/400/415 with Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 22/23/24 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 2-9/16 2-9/16 2-7/8 3 3 3-3/8 3 3-1/2 3-3/8 2.6 3.7 4.2 65 65 73 76 76 86 76 89 86 1.2 1.7 1.9 13 13 13 C0050E4HFB C0075E4HFB C0100E4HFB 110. 115. 125. 150 200 250 3-3/16 3-13/16 3-13/16 3-3/4 4-1/2 4-1/2 4 4 4-3/8 6.7 8.4 10.2 81 97 97 95 114 114 102 102 111 3.0 3.8 4.6 13 13 13 C0150E4HFB C0200E4HFB C0250E4HFB 142. 152. 181. Primary: 550/575/600 with Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 22/23/24 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 2-9/16 2-9/16 2-7/8 3 3 3-3/8 3 3-1/2 3-3/8 2.7 3.7 4.2 65 65 73 76 76 86 76 89 86 1.2 1.7 1.9 12 12 12 C0050E4WFB C0075E4WFB C0100E4WFB 110. 115. 125. 150 200 250 3-3/16 3-13/16 3-13/16 3-3/4 4-1/2 4-1/2 4 4 4-3/8 6.7 8.4 10.2 81 97 97 95 114 114 102 102 111 3.0 3.8 4.6 12 12 12 C0150E4WFB C0200E4WFB C0250E4WFB 135. 150. 178. See Page 9-98 for Wiring Diagrams. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 Transformers Industrial Control Transformers 9-104 November 2003 Type MTE Vol. 1, Ref. No. [0404] Table 9-124. Transformers with Primary Fuse Blocks — Product Selection VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Wiring Diagram Style Number Price U.S. $ Primary: 230/460/575 with Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 115/95 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 3-13/16 4-1/4 4-1/4 3 3-3/8 3-3/8 3 3-3/8 3-7/8 3.7 4.7 6.2 97 108 108 76 86 86 76 86 98 1.7 2.1 2.8 5 5 5 C0050E3CFB C0075E3CFB C0100E3CFB 104. 111. 119. 150 200 250 4-9/16 5-3/16 5-3/16 3-3/4 4-1/2 4-1/2 4-1/4 4-1/4 4-3/4 7.9 9.2 9.9 116 132 132 95 114 114 108 108 121 3.6 4.2 4.5 5 5 5 C0150E3CFB C0200E3CFB C0250E3CFB 136. 150. 179. 300 350 500 5-3/16 6-1/8 6-1/8 4-1/2 5-1/4 5-1/4 5-1/8 5 5-7/8 11.9 16.7 21.7 132 156 156 114 133 133 130 127 149 5.4 7.6 9.9 5 5 5 C0300E3CFB C0350E3CFB C0500E3CFB 192. 206. 221. Primary: 380/400/415 with Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 110 x 220 with Jumpers; Fuse Clips Not Available 9 50 75 100 3-15/16 3-15/16 4-1/4 3 3 3-3/8 3 3-1/2 3-9/16 3.2 4.2 5.4 100 100 108 76 76 86 76 89 90 1.5 1.9 2.5 6 6 6 C0050E4DFB C0075E4DFB C0100E4DFB 103. 110. 119. 150 200 250 4-9/16 5-3/16 5-3/16 3-3/4 4-1/2 4-1/2 4 4 4-3/8 7.2 8.9 10.4 116 132 132 95 114 114 102 102 111 3.3 4.0 4.7 6 6 6 C0150E4DFB C0200E4DFB C0250E4DFB 135. 147. 176. 300 350 500 5-3/16 5-3/16 6-1/8 4-1/2 4-1/2 5-1/4 4-3/4 5-1/4 5-5/8 11.2 13.2 20.2 132 132 156 114 114 133 121 133 143 5.1 6.0 9.2 6 6 6 C0300E4DFB C0350E4DFB C0500E4DFB 188. 204. 218. Primary: 200/220/440, 208/230/460, 240/480 with Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 23/110, 24/115, 25/120 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 75 100 3-15/16 4-1/4 4-9/16 3 3-3/8 3-3/4 3-1/4 3-1/2 3-5/8 3.6 5.0 6.1 100 108 116 76 86 95 83 89 92 1.6 2.3 2.8 7 7 7 C0050E5EFB C0075E5EFB C0100E5EFB 94. 101. 111. 150 200 250 4-9/16 5-3/16 5-3/16 3-3/4 4-1/2 4-1/2 4-3/8 4-1/2 5-1/4 8.1 10.8 14.1 116 132 132 95 114 114 111 114 133 3.7 4.9 6.4 7 7 7 C0150E5EFB C0200E5EFB C0250E5EFB 135. 157. 180. 300 350 500 6-1/8 6-1/8 6-1/8 5-1/4 5-1/4 5-1/4 5-1/8 5-3/8 6-7/8 15.7 17.0 23.6 156 156 156 133 133 133 130 136 175 7.1 7.7 10.7 7 7 7 C0300E5EFB C0350E5EFB C0500E5EFB 195. 202. 239. Universal Design (MTE Epoxy Encapsulated) Primary: 240/416/480/600, 230/400/460/575, 220/380/440/550, 208/500 with Two-Pole Primary Fuse Block for Rejection Type Fuses Secondary: 99/120/130, 95/115/125, 91/110/120, 85/100/110 with Fuse Clips for 13/32 x 1-1/2 Fuses 50 100 150 4-1/4 4-9/16 5-3/16 3-3/8 3-3/4 4-1/2 4 4-5/8 4-7/16 4.2 6.8 9.0 108 116 132 86 95 114 102 117 113 1.9 3.1 4.1 8 8 8 C0050E6UFB C0100E6UFB C0150E6UFB 167. 178. 183. 250 350 500 5-3/16 5-13/16 5-13/16 4-1/2 5-1/4 5-1/4 5-7/8 5-5/8 7 14.9 18.8 25.8 132 148 148 114 133 133 149 143 178 6.8 8.5 11.7 8 8 8 C0250E6UFB C0350E6UFB C0500E6UFB 215. 246. 306. See Pages 9-97 and 9-98 for Wiring Diagrams. Type MTG Open Core-Coil Universal Design has been superseded by Type MTE Epoxy Encapsulated Universal Design with no changes to form, fit or function. Type MTE Epoxy Encapsulated Universal Design. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Industrial Control Transformers 9-105 November 2003 Type MTK Vol. 1, Ref. No. [0405] Type MTK Features, Benefits and Functions Product Specifications ■ Industry standards classify insulation systems and rise as shown below: ■ ■ ■ ■ ■ ■ ■ Epoxy resin-impregnated coil. ■ Economical solution for high inrush applications. Application Description Transformers provide stepped down voltages to machine tool control devices enabling control circuits to be isolated from all power and lighting circuits. This allows the use of grounded or ungrounded circuits that are independent of the power or lighting grounds; greater safety is afforded the operator. The control transformer line is particularly adaptable on applications where compact construction is demanded. Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C Standards and Certifications Industry Standards Series-Multiple Windings All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. ■ ■ Table 9-125. Insulation System Classification The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Type MTK Transformers Product Description UL listed. CSA certified. Epoxy resin impregnated coil design. Copper magnet wire for high quality, efficient operation. 50/60 Hz operation. 115°C rise, 180ºC insulation system. Performance meets/exceeds requirements of ANSI/NEMA ST-1. Regulation exceeds ANSI/NEMA requirements for all ratings. 500 – 5000 VA ratings. Insulation System and Temperature Rise Technical Data and Specifications Please refer to Page 9-122. The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 9-106 Transformers Industrial Control Transformers November 2003 Type MTK Vol. 1, Ref. No. [0406] Wiring Diagrams Figure 9-24. Diagram 1 Figure 9-28. Diagram 5 Figure 9-32. Diagram 9 9 Figure 9-25. Diagram 2 Figure 9-33. Diagram 10 Figure 9-29. Diagram 6 Figure 9-26. Diagram 3 Figure 9-30. Diagram 7 240 V 480 V H1 H3 H2 H4 H1 H3 H2 H4 H1 H3 X4 X2 H2 H4 X3 X1 X4 X2 X3 X1 X4 X2 X3 X1 120 V 240 V Figure 9-34. Diagram 11 Figure 9-27. Diagram 4 Figure 9-31. Diagram 8 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Industrial Control Transformers 9-107 November 2003 Type MTK Vol. 1, Ref. No. [0407] Wiring Diagrams Figure 9-36. Diagram 13 Figure 9-37. Diagram 14 X4 X3 X4 X3 X2 H6 115 V 0V 208 V H5 230 V 115 V 400 V H4 0V 0V 460 V H3 X1 Figure 9-39. Diagram 16 X2 9 H6 0V 208 V H5 230 V H4 230 V X1 H3 400 V H2 460 V H1 575 V H2 H2 575 V X1 115 V 24 V 23 V 22 V X2 0V X2 420 V 400 V 380 V 110,115,120 V 440,460,480 V X3 H1 H1 H4 23/24/25 X1 Figure 9-35. Diagram 12 H3 220,230,240 V H2 380,400,416 V H1 24 V 24 V 23 V 22 V H2 0V X2 600 V 575 V 550 V 550,575,600 V H1 X1 Figure 9-38. Diagram 15 CA08101001E For more information visit: www.cutler-hammer.eaton.com Transformers Industrial Control Transformers 9-108 November 2003 Type MTK Vol. 1, Ref. No. [0408] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-126. Type MTK — Product Selection VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Wiring Diagram Style Number Price U.S. $ Primary: 240 x 480, 230 x 460, 220 x 440 Secondary: 120/115/110 500 750 1000 1500 3-13/16 4-7/16 4-7/16 5-11/16 4-1/2 5-1/2 5-1/4 6-3/4 6 6-1/2 7-7/8 6-3/4 13.0 19.5 29.8 30.0 97 113 113 144 114 133 133 171 152 165 200 171 5.9 8.9 13.6 13.6 1 1 1 1 C0500K2A C0750K2A C1000K2A C1500K2A 154. 215. 298. 413. 2000 3000 5000 5-11/16 7-9/16 7-9/16 6-3/4 9 9 7 7-1/2 7-3/4 38.0 53.0 89.0 144 192 192 171 229 229 178 191 197 17.3 24.1 40.5 1 1 1 C2000K2A C3000K2A C5000K2A 452. 700. 1,160. 6-3/8 6-3/4 6-3/4 7-1/8 7-1/2 8-1/4 29.0 33.0 43.0 137 144 144 162 171 171 181 191 210 13.1 15.0 19.5 4 4 4 C1000K3A C1500K3A C2000K3A 329. 452. 497. 8-1/4 10-1/2 64.0 102.0 194 259 229 229 210 267 29.0 46.3 4 4 C3000K3A C5000K3A 770. 1,270. 29.2 33.5 42.5 137 144 192 162 171 229 184 210 192 13.3 15.2 19.3 5 5 5 C1000K3C C1500K3C C2000K3C 339. 462. 511. 8-5/8 13-1/2 63.7 102.0 192 259 229 229 219 343 29.0 46.4 5 5 C3000K3C C5000K3C 798. 1,310. 7-1/8 8-1/4 9-1/4 29.0 43.0 55.0 137 144 144 162 171 171 181 210 235 13.1 19.5 25.0 9 9 9 C1000K3D C1500K3D C2000K3D 339. 462. 511. 8-5/8 11 74.0 108.0 194 259 229 229 219 279 33.5 49.0 9 9 C3000K3D C5000K3D 798. 1,310. 7-1/8 7-1/2 8-1/4 29.0 33.0 43.0 137 144 144 162 171 171 181 191 210 13.1 15.0 19.5 10 10 10 C1000K4C C1500K4C C2000K4C 339. 462. 511. 8-1/4 10-1/2 64.0 102.0 194 259 229 229 210 267 29.0 46.3 10 10 C3000K4C C5000K4C 798. 1,310. 6-1/2 7-1/2 8-1/4 28.0 33.0 43.0 144 144 144 171 171 171 165 191 210 12.7 15.0 19.5 6 6 6 C1000K4D C1500K4D C2000K4D 332. 455. 504. 8-1/4 10-1/2 64.0 102.0 194 259 229 229 210 267 29.0 46.3 6 6 C3000K4D C5000K4D 784. 1,280. Primary: 208/277 Secondary: 120 9 1000 1500 2000 3000 5000 5-3/8 5-11/16 5-11/16 7-5/8 10-3/16 9 9 Primary: 230/460/575 Secondary: 115/95 1000 1500 2000 5-3/8 5-11/16 7-9/16 6-3/8 6-3/4 9 3000 5000 7-9/16 7-3/16 9 9 7-1/8 8-1/4 7-9/16 Primary: 208/380/416 Secondary: 115/95 1000 1500 2000 3000 5000 5-3/8 5-11/16 5-11/16 7-5/8 10-3/16 6-3/8 6-3/4 6-3/4 9 9 Primary: 550/575/600 Secondary: 110/115/120 1000 1500 2000 3000 5000 5-3/8 5-11/16 5-11/16 7-5/8 10-3/16 6-3/8 6-3/4 6-3/4 9 9 Primary: 380/400/415 Secondary: 110 x 220 1000 1500 2000 3000 5000 5-11/16 5-11/16 5-11/16 7-5/8 10-3/16 6-3/4 6-3/4 6-3/4 9 9 See Page 9-106 and for Wiring Diagrams. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Industrial Control Transformers 9-109 November 2003 Type MTK Vol. 1, Ref. No. [0409] Table 9-127. Type MTK — Product Selection VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Wiring Diagram Style Number Price U.S. $ Primary: 240 x 480 with Jumpers Secondary: 120 x 240 with Jumpers, Secondary Fuse Clips Not Applicable 1000 1500 2000 4-7/16 5-11/16 5-3/4 5-1/4 6-3/4 6-3/4 7-7/8 7-1/4 8 26.4 31.0 40.0 113 144 146 133 171 171 200 184 203 12.0 14.1 18.2 11 11 11 C1000K2CXX C1500K2CXX C2000K2CXX 329. 462. 599. 3000 5000 7-5/8 7-5/8 9 9 7-1/2 9-1/4 56.0 85.5 194 194 229 229 191 235 25.5 28.9 11 11 C3000K2CXX C5000K2CXX 770. 1,270. 6-3/4 8-3/4 19.0 26.4 114 114 133 133 171 222 8.6 12.0 3 3 C0750K1B C1000K1B 276. 413. 26.5 38.5 52.0 146 146 146 171 171 171 165 200 233 12.0 17.5 23.6 8 8 8 C1000K6U C1500K6U C2000K6U 511. 746. 928. 68.0 105.0 197 248 229 229 191 267 30.9 47.7 8 8 C3000K6U C5000K6U 1,305. 1,700. Primary: 120 x 240 with Jumpers Secondary: 24 750 1000 4-1/2 4-1/2 5-1/4 5-1/4 Primary: 240/416/480/600, 230/400/460/575, 220/380/440/550, 208/500 Secondary: 99/120/130, 95/115/125, 91/110/120, 85/100/110 1000 1500 2000 5-3/4 5-3/4 5-3/4 6-3/4 6-3/4 6-3/4 3000 5000 7-3/4 9-7/8 9 9 6-1/2 7-7/8 9-3/16 7-1/2 10-1/2 See Page 9-106 for Wiring Diagrams. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 9 9-110 Transformers Industrial Control Transformers November 2003 CE Marked CE Marked Vol. 1, Ref. No. [0410] Features, Benefits and Functions Type MTE ■ ■ ■ ■ ■ Terminal Type A ■ 9 Application Description ■ Transformers provide stepped down voltages to machine tool control devices enabling control circuits to be isolated from all power and lighting circuits. This allows the use of grounded or ungrounded circuits that are independent of the power or lighting grounds; greater safety is afforded the operator. The control transformer line is particularly adaptable on applications where compact construction is demanded. ■ ■ ■ ■ UL listed. CSA certified. Epoxy encapsulated coil design. Copper magnet wire for high quality, efficient operation. Laminations of high quality silicon steel to minimize core losses and optimize performance. Molded-in terminals. 50/60 Hz operation. 55°C rise, class 105 insulation. Performance meets/exceeds requirements of ANSI/NEMA ST-1. Regulation exceeds ANSI/NEMA requirements for all ratings. Non-short circuit proof transformer, isolation type. Finger-Safe Terminal Covers (Optional) ■ ■ Table 9-128. Finger-Safe Terminal Covers Description Catalog Price Number U.S. $ 4 Terminal Transformers 6 Terminal Transformers FSK4 FSK6 Type MTK ■ ■ ■ ■ ■ ■ ■ ■ ■ Fits CE marked designs 50 – 750 VA. Fits MTE designs 25 – 750 VA. 24. 25. Finger-Safe Terminal Covers — FSK4 UL listed. CSA certified. Epoxy resin-impregnated coil design. Copper magnet wire for high quality, efficient operation. 50/60 Hz operation. 115°C rise, 180°C insulation system. Performance meets/exceeds requirements of ANSI/NEMA ST-1. Regulation exceeds ANSI/NEMA requirements for all ratings. 500 – 5000 VA ratings. Finger-Safe Terminal Covers — FSK6 Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Finger-Safe Primary Fuse Block Covers ■ Fits 2-pole primary fuse blocks on MTE designs. Table 9-129. Finger-Safe Primary Fuse Block Covers Description Catalog Number Primary Fuse Block Covers FSKFB Price U.S. $ 38. Options and Accessories Protection Index IP00 When terminal covers are installed on primary and secondary, and fuse block covers are used, the Protection Index is IP20. Finger-Safe Primary Fuse Block Covers Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Industrial Control Transformers 9-111 November 2003 CE Marked Vol. 1, Ref. No. [0411] Product Specifications Wiring Diagrams Overload Capability Short-term overload is designed into transformers as required by ANSI. Basically, dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Figure 9-40. Diagram 1 Figure 9-43. Diagram 4 9 Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-130. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C Figure 9-41. Diagram 2 The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. Figure 9-44. Diagram 5 Series-Multiple Windings Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Figure 9-42. Diagram 3 Figure 9-45. Diagram 6 Technical Data and Specifications Please refer to Page 9-122. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9-112 Transformers Industrial Control Transformers November 2003 CE Marked Vol. 1, Ref. No. [0412] Wiring Diagrams H3 H2 H4 X4 X2 X3 X1 X4 X2 X3 X1 Figure 9-46. Diagram 7 0V 380,400,416 V 220,230,240 V H4 110,115,120 V H1 440,460,480 V H1 H3 H2 H4 H3 23/24/25 H1 H3 H2 H4 H2 0V 480 V 550,575,600 V H1 240 V X3 X2 X1 X4 X2 X3 X1 Figure 9-53. Diagram 14 120 V 240 V H6 0V 208 V H5 230 V H4 230 V 24 V 115 V H2 0V 600 V 575 V 550 V H3 400 V Figure 9-50. Diagram 11 H1 H2 575 V H1 460 V 9 Figure 9-47. Diagram 8 X4 X4 X2 X1 H5 H6 0V 208 V H4 X3 X2 115 V 0V 115 V H2 Figure 9-48. Diagram 9 24 V 23 V 22 V H3 230 V 575 V H2 0V 420 V 400 V 380 V H1 400 V X1 Figure 9-51. Diagram 12 H1 X2 Figure 9-54. Diagram 15 460 V X2 24 V 23 V 22 V X3 X1 Figure 9-55. Diagram 16 X1 Figure 9-52. Diagram 13 Figure 9-49. Diagram 10 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Industrial Control Transformers 9-113 November 2003 CE Marked Vol. 1, Ref. No. [0413] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-131. Type MTE CE Marked IP00 VA Dimensions (Inches) Height Width Weight Lbs. Depth Dimensions (mm) Height Width Depth Weight kg Wiring Diagram Style Number Price U.S. $ Primary: 240 x 480, 230 x 460, 220 x 440 with Jumpers Secondary: 120/115/110 50 75 100 150 2-9/16 2-7/8 3-3/16 3-13/16 3 3-3/8 3-3/4 4-1/2 3-3/8 3-1/2 3-5/8 4 3.5 4.8 5.9 8.5 65 73 81 97 76 86 95 114 86 89 92 102 1.6 2.2 2.7 3.9 1 1 1 1 CE0050E2A CE0075E2A CE0100E2A CE0150E2A 98. 110. 122. 149. 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4-1/2 4-3/4 5-1/4 10.6 11.3 13.2 97 97 97 114 114 114 114 121 133 4.8 5.1 6.0 1 1 1 CE0200E2A CE0250E2A CE0300E2A 159. 206. 217. 350 500 750 4-3/4 4-3/4 4-3/4 5-1/4 5-1/4 5-1/4 5 6 7-3/8 14.9 21.0 29.8 121 121 121 133 133 133 127 152 187 6.8 9.5 13.5 1 1 1 CE0350E2A CE0500E2A CE0750E2A 252. 274. 406. 9 Primary: 240 x 480 with Jumpers Secondary: 24 50 75 100 150 2-9/16 2-7/8 3-3/16 3-13/16 3 3-3/8 3-3/4 4-1/2 3-1/4 3-1/4 3-5/8 4 3.4 4.2 5.9 8.5 65 73 81 97 76 86 95 114 83 83 92 102 1.5 1.9 2.7 3.9 2 2 2 2 CE0050E2B CE0075E2B CE0100E2B CE0150E2B 109. 119. 135. 168. 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4-1/4 4-3/4 5-1/4 10.6 11.3 13.2 97 97 97 114 114 114 108 121 133 4.5 5.1 6.0 2 2 2 CE0200E2B CE0250E2B CE0300E2B 179. 227. 246. 350 500 750 4-3/4 4-3/4 4-3/4 5-1/4 5-1/4 5-1/4 5 5-1/2 7 14.9 19.2 28.1 121 121 121 133 133 133 127 140 178 6.8 8.7 12.8 2 2 2 CE0350E2B CE0500E2B CE0750E2B 276. 301. 441. Primary: 120 x 240 with Jumpers Secondary: 24 50 75 100 150 2-9/16 2-7/8 3-3/16 3-13/16 3 3-3/8 3-3/4 4-1/2 3-1/4 3-1/4 3-5/8 4 3.4 4.2 5.9 8.5 65 73 81 97 76 86 95 114 83 83 92 102 1.5 1.9 2.7 3.9 3 3 3 3 CE0050E1B CE0075E1B CE0100E1B CE0150E1B 109. 119. 135. 168. 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4-1/4 4-3/4 5-1/4 10.6 11.3 13.2 97 97 97 114 114 114 108 121 133 4.5 5.1 6.0 3 3 3 CE0200E1B CE0250E1B CE0300E1B 179. 227. 246. 350 500 750 4-3/4 4-3/4 4-3/4 5-1/4 5-1/4 5-1/4 5 5-1/2 7-3/8 14.9 19.2 29.8 121 121 121 133 133 133 127 140 187 6.8 8.7 13.5 3 3 3 CE0350E1B CE0500E1B CE0750E1B 276. 301. 441. Primary: 550/575/600 Secondary: 110/115/120 50 75 100 150 2-9/16 2-7/8 3-3/16 3-13/16 3 3-3/8 3-3/4 4-1/2 3-3/8 3-1/2 3-5/8 4 3.5 4.8 5.9 8.5 65 73 81 97 76 86 95 114 86 89 92 102 1.6 2.2 2.7 3.9 10 10 10 10 CE0050E4C CE0075E4C CE0100E4C CE0150E4C 107. 118. 133. 166. 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4-1/2 4-3/4 5-1/4 10.6 11.3 13.2 97 97 97 114 114 114 114 121 133 4.8 5.1 6.0 10 10 10 CE0200E4C CE0250E4C CE0300E4C 177. 224. 243. 350 500 750 4-3/4 4-3/4 4-3/4 5-1/4 5-1/4 5-1/4 5 6 7-3/8 14.9 21.0 29.8 121 121 121 133 133 133 127 152 187 6.8 9.5 13.5 10 10 10 CE0350E4C CE0500E4C CE0750E4C 273. 298. 438. See Pages 9-111 and 9-112 for Wiring Diagrams. Note: Transformers are designed to operate in a maximum ambient of 40°C. Contact your local Cutler-Hammer sales office for availability on additional CE Marked control transformers. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 Transformers Industrial Control Transformers 9-114 November 2003 CE Marked Vol. 1, Ref. No. [0414] Table 9-132. Type MTE CE Marked IP00 VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Wiring Diagram Style Number Price U.S. $ Primary: 380/400/415 Secondary: 110 x 220 with Jumpers 50 75 100 150 2-9/16 2-7/8 3-3/16 3-13/16 3 3-3/8 3-3/4 4-1/2 3-1/2 3-1/2 3-5/8 4 3.5 4.8 5.9 8.5 65 73 81 97 76 86 95 114 89 89 92 102 1.6 2.2 2.7 3.9 6 6 6 6 CE0050E4D CE0075E4D CE0100E4D CE0150E4D 143. 154. 166. 194. 200 250 300 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4-1/2 4-3/4 5-1/4 10.6 11.3 13.2 97 97 97 114 114 114 114 121 133 4.8 5.1 6.0 6 6 6 CE0200E4D CE0250E4D CE0300E4D 206. 268. 281. 350 500 750 3-13/16 4-3/4 4-3/4 4-1/2 5-1/4 5-1/4 5-1/2 6 7-3/8 15.2 21.0 29.8 97 121 121 114 133 133 140 152 187 6.9 9.5 13.5 6 6 6 CE0350E4D CE0500E4D CE0750E4D 327. 357. 630. Primary: 200/220/440, 208/230/460, 240/480 Secondary: 23/110, 24/115, 25/120 9 50 75 100 2-7/8 3-3/16 3-3/16 3-3/8 3-3/4 3-3/4 3-1/4 3-5/8 4-3/8 4.2 5.9 7.9 65 81 81 86 95 95 83 92 111 1.9 2.7 3.6 7 7 7 CE0050E5E CE0075E5E CE0100E5E 133. 147. 165. 150 200 250 3-13/16 3-13/16 3-13/16 4-1/2 4-1/2 4-1/2 4-1/4 5 5-1/2 10.0 12.8 15.2 97 97 97 114 114 114 108 127 140 4.5 5.8 6.9 7 7 7 CE0150E5E CE0200E5E CE0250E5E 201. 214. 278. 300 350 500 4-3/4 4-3/4 4-3/4 5-1/4 5-1/4 5-1/4 5-3/8 5-1/2 7-1/4 16.8 19.2 27.0 121 121 121 133 133 133 137 140 184 7.6 8.7 12.3 7 7 7 CE0300E5E CE0350E5E CE0500E5E 300. 339. 375. See Pages 9-111 and 9-112 for Wiring Diagrams. Note: Transformers are designed to operate in a maximum ambient of 40°C. Contact your local Cutler-Hammer sales office for availability on additional CE Marked control transformers. For other ratings or styles not shown, refer to Eaton’s Cutler-Hammer business. For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E Transformers Industrial Control Transformers 9-115 November 2003 CE Marked Vol. 1, Ref. No. [0415] Factory Mounted Finger-Safe Terminal Covers Terminal Type A Terminal Type B Terminal Type C Table 9-133. Type MTK CE Marked with Factory Mounted Finger-Safe Terminal Covers IP20 VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Terminal Type Wiring Style Diagram Number Price U.S. $ Primary: 240 x 480, 230 x 460, 220 x 440 with Jumpers Secondary: 120/115/110 250 300 350 500 4 4 4 4 4-1/2 4-1/2 4-1/2 4-1/2 4-5/16 4-7/8 5-3/16 5-5/8 8.8 11.0 11.2 14.8 102 102 102 102 114 114 114 114 110 124 132 143 4.0 5.0 5.1 6.7 A A A A 1 1 1 1 CE0250K2AFS CE0300K2AFS CE0350K2AFS CE0500K2AFS 206. 218. 227. 234. 750 1000 1500 4-1/2 5-5/16 7-1/2 5-1/4 6-3/8 6-3/4 5-15/16 5-5/16 6-1/8 18.0 26.3 40.0 114 135 191 133 162 172 151 135 156 8.2 11.9 18.1 A A C 1 1 1 CE0750K2AFS CE1000K2AFS CE1500K2AFS 320. 497. 686. 2000 3000 5000 7-1/2 9-3/8 9-3/8 6-3/4 9 9 6-7/16 6-1/4 8-3/4 45.1 65.2 104.8 191 238 238 172 229 229 164 159 222 20.5 29.6 47.5 C C C 1 1 1 CE2000K2AFS CE3000K2AFS CE5000K2AFS 753. 1,115. 1,595. Primary: 240 x 480 with Jumpers Secondary: 24 250 300 350 5-5/8 5-5/8 5-5/8 4-1/2 4-1/2 4-1/2 3-1/4 3-5/8 4-3/16 8.2 9.5 12.2 143 143 143 114 114 114 83 92 106 3.7 4.3 5.5 C C C 2 2 2 CE0250K2BFS CE0300K2BFS CE0350K2BFS 260. 276. 293. 500 750 1000 5-5/8 6-1/2 7-3/16 4-1/2 5-1/4 6-3/8 4-11/16 5-15/16 5-9/16 14.4 19.5 26.2 143 165 183 114 133 162 119 151 141 6.5 8.9 11.9 C C C 2 2 2 CE0500K2BFS CE0750K2BFS CE1000K2BFS 313. 368. 543. Primary: 120 x 240 with Jumpers Secondary: 24 250 300 350 5-5/8 5-5/8 5-5/8 4-1/2 4-1/2 4-1/2 3-1/4 3-5/8 4-3/16 8.3 9.3 12.0 143 143 143 114 114 114 83 92 106 3.8 4.2 5.4 C C C 3 3 3 CE0250K1BFS CE0300K1BFS CE0350K1BFS 260. 276. 293. 500 750 1000 5-5/8 6-1/2 7-3/16 4-1/2 5-1/4 6-3/8 4-13/16 5-15/16 5-9/16 14.4 19.5 25.2 143 165 183 114 133 162 122 151 141 6.5 8.9 11.4 C C C 3 3 3 CE0500K1BFS CE0750K1BFS CE1000K1BFS 313. 368. 543. Primary: 200/220/440, 208/230/460, 240/480 Secondary: 23/110, 24/115, 25/120 250 300 350 3-7/8 3-7/8 3-7/8 4-1/2 4-1/2 4-1/2 4-7/16 4-3/4 5-3/16 12.5 14.0 15.3 98 98 98 114 114 114 113 121 140 5.7 6.3 6.9 B B B 7 7 7 CE0250K5EFS CE0300K5EFS CE0350K5EFS 267. 287. 328. 500 750 1000 5-1/16 7-3/16 7-3/16 5-1/4 6-3/8 6-3/8 6-1/4 5-13/16 6-3/16 20.8 29.8 30.2 129 183 183 133 162 162 159 148 157 9.4 13.5 13.7 B C C 7 7 7 CE0500K5EFS CE0750K5EFS CE1000K5EFS 345. 595. 665. Primary: 220/380/440/550, 230/400/460/575, 240/416/480/600 Secondary: 23/110, 24/115, 25/120 250 300 350 3 7/8 3-7/8 4-7/16 4 1/2 4-1/2 5-1/4 5 3/8 5-11/16 5-1/2 14.3 15.8 16.5 98 98 113 114 114 133 137 144 140 6.5 7.2 7.5 B B B 14 14 14 CE0250K2UFS CE0300K2UFS CE0350K2UFS 400. 413. 452. 500 750 1000 5-1/16 7-3/16 7-3/16 5-1/4 6-3/8 6-3/8 6-3/16 5-11/16 6-7/8 20.5 28.8 39.4 129 183 183 133 162 162 157 144 175 9.3 13.1 17.9 B C C 14 14 14 CE0500K2UFS CE0750K2UFS CE1000K2UFS 539. 606. 693. See Pages 9-111 and 9-112 for Wiring Diagrams. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. Contact your local Cutler-Hammer sales office for availability on additional CE Marked control transformers. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Industrial Control Transformers 9-116 November 2003 CE Marked Vol. 1, Ref. No. [0416] Table 9-134. Type MTK CE Marked with Factory Mounted Finger-Safe Terminal Covers IP20 VA Dimensions (Inches) Height Width Depth Weight Lbs. Dimensions (mm) Height Width Depth Weight kg Terminal Type Wiring Style Diagram Number Pricing U.S. $ Primary: 208/230/400/460/575 Secondary: 24 /115/230 250 300 350 500 3-7/8 3-7/8 4-7/16 4-7/16 4-1/2 4-1/2 5-1/4 5-1/4 5-1/2 6-1/16 5-3/4 7-5/16 14.9 17.4 17.8 26.6 98 98 113 113 114 114 133 133 140 154 146 186 6.8 7.9 8.1 12.1 B B B B 15 15 15 15 CE0250K2VFS CE0300K2VFS CE0350K2VFS CE0500K2VFS 424. 452. 487. 546. 750 1000 1500 5-15/16 7-1/2 7-1/2 6-3/8 6-3/4 6-3/4 6-3/16 6-7/8 6-3/4 32.5 44.0 45.4 151 191 191 162 172 172 157 175 172 14.7 20.0 20.6 B C C 15 15 16 CE0750K2VFS CE1000K2VFS CE1500K2WFS 753. 840. 865. 2000 3000 5000 9-3/8 9-3/8 9-3/8 9 9 9 6-1/4 8-1/8 9-15/16 58.6 92.9 127.4 238 238 238 229 229 229 159 206 252 26.6 42.1 57.8 C C C 16 16 16 CE2000K2WFS CE3000K2WFS CE5000K2WFS 1,020. 1,295. 1,585. Primary: 240/416/480/600, 230/400/460/575, 220/380/440/550, 208/500 Secondary: 99/120/130, 95/115/125, 91/110/120, 85/100/110 250 300 350 4 4 4 4-1/2 4-1/2 4-1/2 5-1/16 5-1/2 5-1/2 11.4 13.6 14.2 102 102 102 114 114 114 135 140 140 5.2 6.2 6.4 A A A 8 8 8 CE0250K6UFS CE0300K6UFS CE0350K6UFS 410. 424. 455. 500 750 1000 4-1/2 4-1/2 5-1/4 5-1/4 5-1/4 6-3/8 5-5/8 5-5/8 6-1/16 17.4 27.5 27.9 114 114 133 133 133 162 143 187 154 7.9 12.5 12.6 A A A 8 8 8 CE0500K6UFS CE0750K6UFS CE1000K6UFS 539. 634. 711. 1500 2000 3000 5-13/16 7-5/8 8-1/4 6-3/4 9 9 6-5/16 5-3/4 6-9/16 43.1 56.0 76.2 148 194 210 172 229 229 160 146 167 19.5 25.4 34.6 A B B 8 8 8 CE1500K6UFS CE2000K6UFS CE3000K6UFS 847. 991. 1,265. 9 See Pages 9-111 and 9-112 for Wiring Diagrams. 24 volt secondary only available through 1000 VA. Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. Contact your local Cutler-Hammer sales office for availability on additional CE Marked control transformers. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Industrial Control Transformers 9-117 November 2003 CE Marked Vol. 1, Ref. No. [0417] Table 9-135. Acceptable Rating of Primary Overcurrent Protection for CE Marked Control Transformers Fuses 10 x 38 mm (13/32” x 1-1/2”) Time-lag (IEC 269) Sec. Voltage 50 75 100 150 200 250 300 350 500 750 115 120 200 2.0 2.0 1.0 2.0 2.0 2.0 4.0 4.0 2.0 4.0 4.0 4.0 6.0 6.0 4.0 6.0 6.0 4.0 8.0 8.0 4.0 10.0 10.0 6.0 12.0 12.0 8.0 20.0 20.0 12.0 208 220 230 1.0 1.0 1.0 2.0 1.0 1.0 2.0 2.0 2.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 6.0 6.0 6.0 8.0 6.0 6.0 12.0 10.0 10.0 240 277 380 1.0 .5 .5 1.0 1.0 1.0 2.0 1.0 1.0 4.0 2.0 2.0 4.0 4.0 2.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 6.0 6.0 6.0 10.0 8.0 6.0 400 415 440 .5 .5 .5 .5 .5 .5 1.0 1.0 1.0 2.0 1.0 1.0 2.0 2.0 2.0 4.0 4.0 2.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 6.0 6.0 6.0 460 480 550 .5 .5 .5 .5 .5 .5 1.0 .5 .5 1.0 1.0 1.0 2.0 2.0 1.0 2.0 2.0 2.0 4.0 4.0 2.0 4.0 4.0 4.0 4.0 4.0 4.0 6.0 6.0 4.0 575 600 .5 .5 .5 .5 .5 .5 1.0 1.0 1.0 2.0 2.0 2.0 2.0 2.0 4.0 4.0 4.0 4.0 4.0 4.0 Table 9-136. Acceptable Maximum Rating of Secondary Overcurrent Protection Miniature Fuses 5 x 20 mm Time-lag (IEC 127-2/III) Sec. Voltage 50 75 100 150 200 250 300 350 500 750 23 24 25 2.50 2.50 2.50 4.00 4.00 4.00 5.00 5.00 5.00 8.00 8.00 8.00 10.0 10.0 10.0 12.00 12.00 12.00 16.00 16.00 16.00 16.00 16.00 16.00 25.00 25.00 25.00 — 32.00 32.00 90 95 100 .63 .63 .50 1.00 .80 .80 1.25 1.25 1.00 2.00 1.60 1.60 2.50 2.50 2.00 3.15 3.15 2.50 4.00 4.00 3.15 4.00 4.00 4.00 6.30 6.30 5.00 10.00 8.00 8.00 110 115 120 .50 .50 .50 .80 .80 .63 1.00 1.00 1.00 1.60 1.60 1.25 2.00 2.00 2.00 2.50 2.50 2.50 3.15 3.15 2.50 4.00 3.15 3.15 5.00 5.00 5.00 8.00 8.00 6.30 220 230 240 .25 .25 .25 .40 .40 .315 .50 .50 .50 .80 .80 .63 1.00 1.00 1.00 1.25 1.25 1.25 1.60 1.60 1.25 1.60 1.60 1.60 2.50 2.50 2.50 4.00 4.00 3.15 Note: For values over 6.3A use 10 x 38 mm time-lag (IEC - 269-3-1). Ta = 40°C Control Type CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers Industrial Control Transformers 9-118 November 2003 Type AP Type AP Vol. 1, Ref. No. [0418] Standards and Certifications Industry Standards All Cutler-Hammer dry-type distribution and control transformers by Eaton Corporation are built and tested in accordance with applicable NEMA, ANSI, and IEEE Standards. Type AP Transformer 9 Product Description ■ Sand and resin encapsulated designs. Application Description Transformers provide stepped down voltages to machine tool control devices enabling control circuits to be isolated from all power and lighting circuits. This allows the use of grounded or ungrounded circuits that are independent of the power or lighting grounds; greater safety is afforded the operator. The control transformer line is particularly adaptable on applications where compact construction is demanded. Features, Benefits and Functions ■ ■ ■ ■ ■ ■ ■ ■ UL recognized. Resin encapsulated. 60 Hz operation. 115°C winding rise. Convenient screw-type terminal board. Bottom or side/wall mounting designs. Performance meets/exceeds requirements of ANSI/NEMA ST-1. Regulation exceeds ANSI/NEMA requirements for all ratings. Sound Levels All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 levels. Winding Terminations Product Specifications Cutler-Hammer business recommends external cables be rated 90ºC (sized at 75°C ampacity) for encapsulated designs. Overload Capability Series-Multiple Windings Short-term overload is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one-hour; and 125% load for four-hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with an “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 X 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 120 X 240 winding can be connected for either 120 (parallel) or 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 mid-point. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify insulation systems and rise as shown below: Table 9-137. Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40°C 40°C 40°C 40°C 55°C 80°C 115°C 150°C 10°C 30°C 30°C 30°C 105°C 150°C 185°C 220°C Technical Data and Specifications Please refer to Page 9-122. The design life of transformers having different insulation systems is the same — the lower temperature systems are designed for the same life as the higher temperature systems. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers Industrial Control Transformers 9-119 November 2003 Type AP Vol. 1, Ref. No. [0419] Product Selection Additional Product Selection information begins on Page 9-136. Table 9-138. Type AP kVA Mounting Dimensions (Inches) Height Width Depth Weight Dimensions (mm) Lbs. Height Width Depth Weight kg Frame Wiring Style Diagram Number Price U.S. $ 240/480 Volts to 120/240 Volts, 60 Hz 3 5 7.5 10 15 Bottom Bottom Bottom Bottom Bottom 8-5/16 10-3/4 10-3/4 10-3/4 12 9-9/16 10-3/4 10-3/4 10-3/4 13-3/16 8-13/16 8 -11/16 10-3/16 11-3/8 10-7/16 65 104 129 148 197 227 273 273 273 305 243 273 273 273 335 224 221 259 289 265 29.5 47.2 58.6 67.2 89.4 FR133 FR99 FR100 FR101 FR134 5 5 5 5 5 C0003P7GB C0005P7GB C0007P7GB C0010P7GB C0015P7GB 1,375. 1,710. 2,350. 2,930. 3,970. 3 5 7.5 10 15 Side/Wall Side/Wall Side/Wall Side/Wall Side/Wall 9-3/4 11-5/8 11-5/8 11-5/8 12-7/8 8-13/16 8-11/16 10-13/16 11-3/8 10-7/16 9-9/16 10-3/4 10-3/4 10-3/4 13-3/16 65 104 129 148 197 248 295 295 295 327 224 221 275 289 265 243 273 273 273 335 29.5 47.2 58.6 67.2 89.4 FR292 FR256 FR257 FR258 FR259 5 5 5 5 5 C0003P7GS C0005P7GS C0007P7GS C0010P7GS C0015P7GS 1,375. 1,710. 2,350. 2,930. 3,970. See Page 9-91 for Wiring Diagrams. 9 Note: For additional information refer to the Cutler-Hammer Industrial Control Transformer Binder B1228A. For other ratings or styles not shown, or for special enclosure types (including stainless steel) refer to Eaton’s Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 Transformers General Purpose & Industrial Control Transformers 9-120 November 2003 Options, Accessories and Parts Vol. 1, Ref. No. [0420] Options and Accessories Terminal Extension Kit (Order Separately) Weathershield Kit Note: For 316 grade stainless steel add the suffix ‘S’ to the catalog number. Wall Mounting Bracket A terminal extension kit is used to allow front access to the rear terminals on most 500 and 750 kVA transformers (transformers on frames 919 and 920) when insufficient space is available at the rear of the transformer. Eaton’s Cutler-Hammer business recommends a minimum of 6-inch clearance from the wall to maintain proper ventilation. Table 9-140. Terminal Extension Kit Fits Frame Bus Size(s) Material 9 Catalog Number Price U.S. $ 919 Aluminum EXT55AL 500. 919 Copper EXT55CU 750. 920 Aluminum EXT77AL 500. 920 Copper 750. EXT77CU Effective June 1, 2001 frame numbers will have a prefix of FR, i.e., FR819. Dimensions, accessories, etc. are still applicable as if the FR did not exist. Weathershield Kit Wall mounting brackets fit the following frames. A weathershield kit consisting of a front and rear cover shield must be installed on all ventilated dry-type distribution transformers when the unit is located outdoors. The shields protect the transformer top ventilation openings against rain but allow for proper ventilation. Field installation hardware is not required. Refer to specific transformer listing for selection of weathershield kit. Proper installation provides a NEMA 3R rating. Table 9-141. Availability Guide — Wall Mounting Bracket WMB01 Frame Sizes Catalog Price Number U.S. $ 809, 810, 811, 816, 817, 818 WS11 350. 814 WS13 800. 819, 820 WS16 800. 808, 909, 910, 911, 912, 910A, 911A, 912A WS31 350. 812, 813, 913A, 913B, 914A, WS33 915A, 916, 914B, 915B 350. 916A WS19 350. 917, 918, 918A WS34 800. 919, 920 WS35 1,360. 922 WS36 1,360. 815 WS15 350.00 Catalog Number Price U.S. $ Type DS-3 (Single-Phase Compatible) 809, 810, 811, 812, 813, 815, WMB01 816, 817, 818, 819, 820, 835, 836, 837, 814A 275. Type DT-3, K-Factor, Drive Isolation (Three-Phase Compatible) 909, 910, 911, 912, 910A, 911A, 912A, 913A, 913B, 914A, 914B, 915A, 915B Table 9-139. Weathershield Kit Fits Frame Size(s) Wall Mounting Bracket Wall mounting brackets are used to wall mount most 15 through 75 kVA and some 100 and 112.5 kVA Type DS-3 and DT-3 transformers. See availability guide. This bracket allows for 6-inch clearance from the wall as recommended by the Cutler-Hammer business. WMB01 275. Effective June 1, 2001 frame numbers will have a prefix of FR, i.e., FR819. Dimensions, accessories, etc. are still applicable as if the FR did not exist. Effective June 1, 2001 frame numbers will have a prefix of FR, i.e., FR819. Dimensions, accessories, etc. are still applicable as if the FR did not exist. For stainless steel weathershields, add the suffix “S” to a catalog number, i.e., WS31S. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose & Industrial Control Transformers 9-121 November 2003 Options, Accessories and Parts Vol. 1, Ref. No. [0421] Table 9-142. Terminal Lug Kits for Type DT-3 Transformers Typical Sizing Terminal Lugs Cable Range Hardware Quantity 15 – 37.5 kVA Single-Phase 15 – 45 kVA Three-Phase #14 – #2 #6 – 250 kcmil 8 4 50 – 75 kVA Single-Phase 75 – 112.5 kVA Three-Phase #6 – 250 kcmil 100 – 167 kVA Single-Phase 150 – 300 kVA Three-Phase 500 kVA Three-Phase Bolt Size Price U.S. $ 1/4-20 x 3/4 8 LKS1 95. 12 1/4-20 x 3/4 1/4-20 x 1-3/4 8 8 LKS2 190. #6 – 250 kcmil #2 – 600 kcmil 3 22 1/4-20 x 3/4 3/8-16 x 2 3 16 LKS3 740. #2 – 600 kcmil 29 3/8-16 x 2 18 LKS4 900. Table 9-144. Replacement Parts for Mini-Power Centers Table 9-143. Rodent Screens Description Frame Size(s) Catalog Number Rodent screens are used to discourage entry by birds or rodents 909 910A, 911, 912 913B, 914B, 915B RS01 RS02 RS03 350. 350. 350. 916 917, 918, 918A 919, 920 916A 922 RS04 RS05 RS06 RS07 RS08 Catalog Number Quantity Price U.S. $ Frame Deadfront Cover (Breaker Cover) Front Cover 800. 800. 1,360. 800. 1,360. 283 284 285 286 287 47-37503 47-37503-2 47-37503-3 47-37503-4 47-37503-5 7074C98H04 7074C98H01 7074C98H02 7074C98H02 7074C98H03 289 290 291 47-37459 47-37459-2 47-37459-3 7074C44H01 7074C44H02 7074C44H03 Effective June 1, 2001 frame numbers will have a prefix of FR, i.e. FR819. Dimensions, accessories, etc. are still applicable as if the FR did not exist. 289A 290A 291A 47-42072-1 47-42072-2 47-42072-3 7074C44H01 7074C44H02 7074C44H03 Table 9-145. Case Parts for Ventilated Units Frame(s) Panels Top Cover Front or Back Side (2 required per transformer) Bottom Part Number Part Number Three-Phase, 600 Volt Class 909 910, 911, 912 913A, 914A, 915A 916 917, 918 7073C37P01 1714C46P01 1714C47P03 1714C60P01 1714C65P01 1714C44P03 1714C44P01 1714C44P07 1714C56P01 1714C64P01 7073C20P05 7073C20P01 7073C20P02 7073C20P03 7073C20P04 1714C45P01 1714C45P01 1714C45P02 1714C58P01 1714C67P01 919, 920 2D46331P03 (Upper Panel) 2D46331P04 (Lower Panel) 2D46332P01 2D46331P01 (Cutout Cover Plate) — — 2D46331P02 922 2D46391H03 (Back Upper Panel) 2D46391H06 (Front Upper Panel) 2D46391H08 (Lower Panel) 2D46392H01 — — — 2D46391H02 918A 47-41801 47-41800 47-41799 47-41802 910A, 911A, 912A 913B, 914B, 915B 916A 47-40592 47-40580 47-41790 47-40591 47-40578 47-41789 47-40589 47-41792 47-41788 1714C45P01 1714C45P02 47-41791 809 810, 811, 835 812, 813, 836, 837, 838 814 7073C16P03 7073C16P01 7073C16P02 7073C54P01 7073C18P04 7073C18P01 7073C18P02 7073C18P05 7073C14P03 7073C14P01 7073C14P02 7073C14P04 7073C17P01 7073C17P01 7073C17P02 7073C17P03 815 816 817, 818 819, 820 47-39433 47-40452 47-40457 47-40574 47-39430 47-40451 47-40456 47-40573 47-39429 47-40449 47-40454 47-40459 47-39431 47-40453 47-40458 47-40575 Single-Phase, 600 Volt Class Effective June 1, 2001 frame numbers will have a prefix of FR, i.e., FR819. Dimensions, accessories, etc. are still applicable as if the FR did not exist. Note: Parts listed are for standard catalog listed transformers. Units with modifications may require different parts. (Frame No. from transformer nameplate required). Note: Transformer nameplate and UL label are not field replaceable. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . DT-1 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 9-122 Transformers General Purpose & Industrial Control Transformers November 2003 Technical Data and Specifications Technical Data and Specifications Vol. 1, Ref. No. [0422] General Purpose — DS-3 Ventilated Non-Linear (K-factor) General Purpose — EP Sand and Resin Encapsulated 9 EP Sand and Resin Encapsulated Cutler-Hammer EP general purpose transformers by Eaton Corporation are single-phase, sand and resin encapsulated designs suitable for indoor or outdoor applications. The totallyenclosed non-ventilated NEMA 3R enclosure makes it ideally suited for use in areas that contain dust, moisture, or corrosive fumes. Available in ratings through 37.5 kVA and 4160 volts, type EP transformers can be mounted in any position for indoor installations and in upright positions only for outdoor installations. Type EP transformers utilize a 185°C insulation system with 115°C rise standard. DS-3 Ventilated Non-Linear Transformer DS-3 general purpose transformers are single-phase ventilated units designed primarily for indoor locations (also for outdoor with the addition of weathershields). The DS-3 utilizes a 220°C insulation system with 150°C rise and is available in ratings of 15 – 167 kVA and up to 4160 volts primary. Non-linear transformers are designed to withstand the overheating effects caused by harmonics resulting from non-linear (non-sinusoidal) loads. Office equipment using solid-state switching power supplies such as computers, laser printers, and copiers are sources of harmonic distortion in power systems. Non-linear transformers are specifically designed for these applications. Their coils are designed to reduce stray losses, their cores have reduced induction levels, and their neutrals can carry at least 200% of normal phase current. General Purpose — DT-3 Ventilated Energy Efficient General Purpose — EPT Sand and Resin Encapsulated Three-Phase DT-3 Ventilated The three-phase DT-3 ventilated dry-type is available in ratings of 15 – 1500 kVA and up to 4160 volts. Its 220°C insulation system (150°C rise) is self-extinguishing. DT-3 enclosures are designed for indoor locations (or outdoors on 600 volts and below with addition of weathershields). EPT Sand and Resin Encapsulated Type EPT sand and resin encapsulated, 3-phase transformers are available in ratings of 3 – 75 kVA, up to 4160 volts primary. The totally-enclosed non-ventilated NEMA 3R enclosure makes the EPT ideally suited for outdoor as well as indoor locations. Type EPT transformers utilize a 185°C insulation system with 115°C standard. NEMA TP-1-1996 — Energy Efficient Cutler-Hammer low temperature rise units are a solution for improved energy efficiency. Their lower conductor losses result in energy conservation and their lower rise give longer insulation life. Available in ratings through 1000 kVA, 115°C or 80°C rise, all CutlerHammer energy efficient units through 750 kVA are UL listed and utilize the 220°C insulation system. NEMA TP-1-1996 Energy Efficient transformers are specifically designed to meet the strict efficiency standards set forth in NEMA Standard TP-1-1996. Cores and coils are optimized to provide maximum efficiency at 35% of nameplate rating. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose & Industrial Control Transformers 9-123 November 2003 Vol. 1, Ref. No. [0423] Shielded Isolation Technical Data and Specifications Mini-Power Center Customer-Furnished Connecting Cables Eaton’s Cutler-Hammer recommends external cables be rated 90°C (sized at 75°C ampacity) for encapsulated designs and 75°C for ventilated designs. Primary and secondary terminal lugs are not included. Lug kits are available separately. Overload Capability Shielded Isolation Transformer “Sensitive” loads such as input circuits of computers, hospital operating rooms, microprocessors, require additional protection from electrical disturbances. The Cutler-Hammer Shielded Isolation transformer by Eaton Corporation uses an electrostatic shield grounded to the transformer case to attenuate electrical disturbances on the line from being transmitted to the load. Shielded Isolation units are similar in design and ratings to the EP, EPT, DS-3, and DT-3. ac Adjustable Frequency Drive and dc Motor Drive Isolation Mini-Power Center The Mini-Power Center replaces 3 individual components — a main breaker, transformer, and panelboard — by combining all 3 into one unit. All interconnecting wiring is performed at the factory. Eaton’s Cutler-Hammer Mini-Power Centers are available with primary main breakers rated up to 600 volts, 100 amperes; encapsulated EP or EPT transformers through 30 kVA; and secondary panelboards with main breakers and provisions for up to 24 one-pole feeder breakers. NEMA 3R enclosure is standard. Buck-Boost Transformer Short-term overload capacity is designed into transformers as required by ANSI. dry-type distribution transformers will deliver 200% nameplate load for one-half hour; 150% load for one hour; and 125% load for four hours without being damaged provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.250 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Seismically Qualified Eaton’s Cutler-Hammer manufactured dry-type distribution transformers are seismically qualified, and exceed requirements of the Uniform Building Code (UBC) and California Code Title 24. Taps Primary taps are available in most ratings to allow compensation for source voltage variations. Series-Multiple Windings Drive Isolation Transformer Drive Isolation transformers are designed especially for 3-phase SCR controlled, variable speed motor drives. Sized by hp and common motor voltages, the Drive Isolation transformer is braced to withstand the mechanical stresses associated with a motor drive. Drive Isolation units are available in ventilated designs (150°C rise) 5 – 800+ hp (through 1500 kVA). Epoxy encapsulated designs (115°C rise) are available in 5 – 20 hp designs by custom order. CA08101001E Buck-Boost Transformer Buck-Boost transformers have 120 x 240 or 240 x 480 volt primaries with 12/24, 16/32, or 24/48 volt secondaries. Their primary use is as auto-transformers for slight upward (“boost”) or downward (“buck”) adjustments in voltages. Eaton’s Cutler-Hammer Buck-Boost transformers are encapsulated designs with totally-enclosed non-ventilated enclosures. Units are 1-phase, but can be installed as a 3-phase bank. For more information visit: www.cutler-hammer.eaton.com Series-multiple windings consist of 2 similar coils in each winding which can be connected in series or parallel (multiple). Transformers with seriesmultiple windings are designated with a “X” or “/” between the voltage ratings, such as voltages of “120/240” or “240 x 480.” If the series-multiple winding is designated by an “X,” the winding can be connected only for a series or parallel. With the “/” designation, a midpoint also becomes available in addition to the series or parallel connection. As an example, a 120 x 240 winding can be connected for either 120 (parallel) OR 240 (series), but a 120/240 winding can be connected for 120 (parallel), or 240 (series), or 240 with a 120 midpoint. 9 9-124 Transformers General Purpose & Industrial Control Transformers November 2003 Technical Data and Specifications Enclosures Non-Linear Ratings Eaton’s Cutler-Hammer ventilated transformers, Types DS-3, DT-3, MD, and KT, utilize a NEMA 2 rated (dripproof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Cutler-Hammer encapsulated (Types EP, EPT, EPZ, and EPTZ) and totally enclosed, non-ventilated (Types DS-3E and DT-3E) transformers utilize a NEMA 3R rated enclosure. The transformers shall be specifically designed to supply circuits with a harmonic profile equal to or less than a K-factor of 4 or 13 as described below without exceeding specified temperature rise. Buck-Boost Transformers 9 Vol. 1, Ref. No. [0424] An autotransformer has only one winding, and is therefore smaller and more economical than the conventional two-winding transformer. In an autotransformer, the primary and secondary are electrically and mechanically connected together. The required secondary voltage is obtained by “tapping-off” from the single winding. Buck-Boost autotransformers are insulated units with 120 x 240 or 240 x 480 volt primaries and 12/24, 16/32, or 24/48 volt secondaries and provide a very economical method for minor voltage adjustments where circuit isolation is not needed. Autotransformers can be used only where local electrical codes permit and isolation of the two circuits is not required. Table 9-146. Non-Linear Ratings Harmonic K-4 K-13 Fundamental 3rd 5th 7th 9th 100.0% 34.0% 22.0% 3.0% 1.0% 100.0% 70.0% 42.0% 5.0% 3.0% .7% .5% .3% .3% 3.0% 1.0% .7% .6% 11th 13th 15th 17th Sound Levels All Cutler-Hammer 600 volt class general purpose dry-type distribution transformers are designed to meet NEMA ST-20 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation will likely be higher due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Table 9-147. Average Sound Levels All Cutler-Hammer general purpose dry-type distribution transformers are designed with sound levels lower than NEMA ST-20 maximum levels. However, consideration should be given to the specific location of the transformers and their installation to minimize the potential for sound transmission to surrounding structures and sound reflection. It is suggested that the following installation methods be included: 1. If possible, mount the transformer away from corners of wall or ceilings. For installation which must be near a corner, use soundabsorbing materials on the walls and ceilings if necessary to eliminate reflection. 2. Provide a solid foundation for mounting the transformer and then use vibration dampening mounts if not already provided in the transformer (Cutler-Hammer encapsulated EP/EPT designs utilize a special encapsulation system and ventilated DS/DT-3 designs contain a built-in vibration dampening system to minimize and isolate sound transmission). 3. Provide flexible conduit to make the connections to the transformer. 4. Locate the transformer as far as possible from areas where high sound levels are undesirable. NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose & Industrial Control Transformers 9-125 November 2003 Technical Data and Specifications Vol. 1, Ref. No. [0425] Table 9-148. Rated Line Amperes for kVA and Voltages of Single-Phase Transformers Amperes for kVA .25 .50 .75 Voltage 120 208 220 240 277 480 600 2400 4160 2.0 4.2 6.3 1.2 2.4 3.6 1.1 2.3 3.4 1.0 2.1 3.1 .9 1.8 2.7 .5 1.0 1.6 .4 .8 1.3 .10 .21 .31 .06 .12 .18 1 1.5 2 8.3 12.5 16.7 4.8 7.2 9.6 4.5 6.8 9.1 4.2 6.2 8.3 3.6 5.4 7.2 2.1 3.1 4.2 1.7 2.5 3.3 .42 .63 .83 .24 .36 .48 3 5 7.5 25 41 62 14.4 24.0 36 13.6 22.7 34 12.5 20.8 31 10.8 18.0 27 6.2 10.4 15.6 5.0 8.3 12.5 1.2 2.1 3.1 .72 1.2 1.8 20.8 31 52 16.7 25 41 4.2 6.2 10.4 2.4 3.6 6.0 10 15 25 83 125 208 48 72 120 45 68 114 41 62 104 36 54 90 37.5 50 75 312 416 625 180 240 360 170 227 341 156 208 312 135 180 270 78 104 156 62 83 125 15.6 20.8 31.3 9.0 12.0 18.0 833 1391 480 802 455 759 416 695 361 602 208 347 166 278 41.7 69.6 24.0 40.1 100 167 Note: Line Current = (kVA x 1000)/Line Voltage Table 9-149. Rated Line Amperes for kVA and Voltages of Three-Phase Transformers Amperes for kVA Voltage 208 240 380 480 600 2400 4160 3 6 9 8.3 16.6 25 7.2 14.4 21.6 4.6 9.1 13.7 3.6 7.2 10.8 2.9 5.8 8.6 .72 1.4 2.2 .42 .83 1.2 15 22.5 30 41.7 62.4 83.4 36.1 54.1 72.3 22.8 34.2 45.6 18.0 27.1 36.1 14.4 21.6 28.9 3.6 5.4 7.2 2.1 3.1 4.2 57.0 68.4 76 45.2 54.2 60.1 36.1 43.4 48.1 9.0 10.8 12.0 5.2 6.3 6.9 37.5 45 50 104 124 139 90.3 108 120 75 112.5 150 208 312 416 180 270 360 114 171 228 90 135 180 72 108 144 18.0 27.1 36.1 10.4 15.6 20.8 225 300 500 624 832 1387 541 721 1202 342 456 760 270 360 601 216 288 481 54.2 72.2 120 31.3 41.6 69.4 750 1000 2084 2779 1806 2408 1140 1519 903 1204 723 963 180 241 104 139 Note: Three-Phase Line Current = (kVA x 1000)/(Line Voltage x 1.732) CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers General Purpose & Industrial Control Transformers 9-126 November 2003 Technical Data and Specifications Vol. 1, Ref. No. [0426] Typical Dimensions and Technical Data Table 9-150. Typical Data for 600-Volt Class General Purpose dry-type Transformers Type EP 115°C Rise 9 EPT 115°C Rise DS-3 150°C Rise DT-3 150°C Rise kVA Dimensions (Inches) Losses in Watts Efficiency N.L. Total 1/4 Load 1/2 Load 3/4 Load Full Load 100% P.F. 80% P.F. % Imp. Sound Level dB 7 7 7 8 6 7 5 7 9 14 15 20 65.3 66.0 82.4 83.4 79.6 79.0 86.9 88.2 84.3 82.5 87.7 88.9 85.6 82.8 86.5 87.8 5.9 9.4 10.3 9.0 6.4 9.2 10.6 9.6 6.5 9.8 11.0 9.8 45 45 45 45 12 13 20 30 14 20 29 24 29 47 57 60 79.0 85.1 86.0 90.8 87.2 90.3 91.3 93.9 89.5 91.4 92.7 94.5 89.6 91.4 92.9 94.4 5.9 5.5 3.9 3.8 7.5 7.0 5.0 4.9 7.5 6.9 5.0 4.9 45 45 45 45 65 113 — — 40 40 69 120 30 30 61 104 90 100 135 215 92.5 94.2 92.0 91.8 94.7 95.7 95.0 95.0 95.0 95.8 95.7 95.8 94.6 95.4 95.7 95.9 4.1 3.6 2.5 2.3 5.2 4.7 3.5 3.3 5.2 4.7 3.5 3.4 45 45 45 45 9-7/8 10-1/2 10-1/2 14-1/8 123 193 216 385 133 208 235 414 129 153 209 191 250 295 435 440 93.2 93.9 94.4 96.8 96.0 96.3 96.6 98.0 96.7 97.0 97.1 98.3 95.9 97.2 97.2 98.4 1.5 1.5 1.6 1.1 2.4 2.5 2.8 2.5 2.5 2.8 3.0 3.1 45 50 50 50 15-15/16 16-1/2 16-1/2 19-11/16 8-5/16 9-7/8 9-7/8 10-7/16 116 143 166 275 123 153 178 300 110 145 195 265 165 275 375 545 87.3 90.9 91.6 93.0 92.6 94.5 95.0 95.7 94.3 95.5 95.9 96.5 94.9 95.7 96.1 96.6 2.1 2.2 2.0 1.9 6.1 3.1 2.8 3.1 7.9 3.7 3.0 3.3 45 45 45 50 26-5/8 26-1/2 30-3/4 25-1/8 28-1/2 30-1/8 12-3/4 14-5/8 15-5/8 422 660 1275 504 745 1450 250 300 400 665 740 945 96.5 97.2 97.7 97.7 98.2 98.6 98.0 98.4 98.8 97.9 98.5 98.8 1.5 1.0 .8 2.5 2.1 1.6 2.7 2.4 1.9 50 50 55 30-1/4 31-1/4 37-5/8 37-5/8 16-7/8 22-5/8 22-5/8 22-5/8 15-7/8 17-1/2 19-1/2 19-1/2 147 212 306 340 165 237 343 381 200 200 250 250 465 790 1160 1595 94.7 97.1 97.4 97.3 96.6 97.7 97.8 97.7 97.1 97.5 97.5 97.4 97.1 97.2 97.2 96.9 1.9 2.5 2.6 2.9 3.4 4.2 4.3 5.7 3.7 4.5 4.6 6.5 45 45 45 45 75 100 167 42-1/8 42-1/8 62-7/8 24 24 30 23-3/8 23-3/8 34 510 560 1200 570 620 1350 350 400 650 2175 2825 3270 97.4 97.8 98.0 97.8 98.0 98.4 97.6 97.7 98.3 97.2 97.3 98.3 2.6 2.7 1.8 5.5 6.0 5.2 6.4 7.3 6.8 50 50 55 15 30 45 75 25 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 14-1/8 19-1/8 152 230 310 480 172 300 370 550 155 250 300 400 665 1795 1685 2535 95.2 95.5 97.2 97.2 96.4 95.9 98.2 97.6 96.3 95.3 98.4 97.2 95.8 94.4 98.5 96.7 3.5 5.3 1.1 3.0 5.2 7.8 3.7 4.8 5.3 7.9 5.0 5.1 45 45 45 50 112.5 150 225 300 39-3/8 46-5/8 56 62-1/4 26-1/8 28 31-1/4 31-1/4 19-1/8 23 24-1/4 30-1/4 600 785 1100 1600 675 870 1200 2150 600 700 900 1100 3830 4430 5795 7065 96.9 97.5 97.9 98.0 97.3 97.8 98.1 98.3 97.0 97.6 97.9 98.1 96.5 97.2 97.5 97.7 3.4 2.7 2.4 2.2 5.8 5.2 5.4 5.3 6.2 5.8 6.4 6.5 50 50 55 55 75 75 76 44-1/2 44-1/2 60 36 36 50 2400 2900 4530 3100 3600 5400 1500 2100 6875 10090 98.6 98.5 98.9 98.9 98.8 98.8 98.7 98.7 1.2 1.3 3.7 4.6 4.9 6.3 60 64 64 15 30 45 75 25 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 14-1/8 19-1/8 152 230 310 480 172 300 370 550 155 250 300 400 655 1460 1475 2060 95.3 95.7 96.7 97.1 96.4 96.3 97.4 97.7 96.3 95.8 97.2 97.6 95.9 95.0 96.9 97.3 3.4 4.6 2.7 2.3 4.8 6.3 4.1 3.9 4.8 6.4 4.2 4.2 45 45 45 50 112.5 150 225 300 39-3/8 46-5/8 56 62-1/4 26-1/8 28 31-1/4 31-1/4 19-1/8 23 24-1/4 30-1/4 600 785 1100 1600 675 870 1200 2150 600 700 900 1100 3220 4340 5640 5950 97.4 97.5 97.8 98.0 97.8 97.8 98.1 98.2 97.6 97.6 97.9 98.0 97.3 97.2 97.6 97.7 2.5 2.6 2.4 2.2 4.6 5.1 5.8 5.5 5.1 5.8 7.2 6.8 50 50 55 55 500 750 75 76 44-1/2 60 36 50 2400 4530 3100 5400 5955 98.5 98.9 99.0 98.8 5.5 60 64 15 30 45 30-1/8 30-1/8 39-3/8 20-1/8 20-1/8 26-1/8 14-1/8 14-1/8 19-1/8 230 310 480 300 370 550 250 300 400 505 810 1135 93.3 95.8 96.1 95.9 97.2 97.4 96.6 97.5 97.6 96.7 97.4 97.5 1.7 1.8 1.7 2.5 2.7 2.8 2.5 2.7 2.9 45 45 45 75 112.5 150 39-3/8 46-5/8 56 26-1/8 28 31-1/4 19-1/8 23 24-1/4 600 785 1100 675 870 1200 600 700 900 1855 2930 2170 96.5 97.2 97.4 97.6 97.8 98.4 97.7 97.8 98.6 97.6 97.5 98.6 1.8 2.1 .9 3.4 3.9 2.5 3.8 4.3 3.0 50 50 50 225 300 500 62-1/4 75 76 31-1/4 44-1/2 60 30-1/4 36 50 1600 2400 4190 2150 3100 4650 1100 1500 4425 3940 97.7 97.8 98.3 98.6 98.3 98.7 98.1 98.7 1.6 .9 3.9 2.6 4.7 3.3 55 55 60 Width 6-1/2 6-1/2 6-1/2 6-1/2 3-7/8 3-7/8 3-7/8 3-7/8 3-1/2 3-1/2 3-1/2 3-1/2 — — — — .25 .5 .75 1 6-1/2 6-1/2 8-3/8 8-3/8 4-7/8 4-7/8 6 6 3-7/8 4-5/8 5-1/2 5-1/2 — — — — 1.5 2 3 5 10-1/2 10-1/2 14-1/4 16 6-3/8 6-3/8 71-1/16 10-3/8 6-1/8 6-1/8 8 9-7/8 7.5 10 15 25 16 19 19 22-5/16 10-3/8 13-3/8 13-3/8 16-3/8 3 6 9 15 13-3/8 15-7/8 15-7/8 17-3/8 30 45 75 15 25 37.5 50 .05 .075 .10 .15 500 750 1000 DT-3 115°C Rise DT-3 80°C Rise Weight Lbs. Depth Al Height Cu 1500 % Regulation 1.0 4.0 Typical values for aluminum windings. Contact Eaton’s Cutler-Hammer business for values of copper windings. For Types DS-3 and DT-3 transformers and all K-factor transformers, allow 6-inch (152.4 mm) clearance between rear of transformer and wall. Actual impedance may be ± 7.5%. Type EPT transformers 3-15 kVA are T-T connected. Refer to the Cutler-Hammer business. Note: Performance data is based upon 480 volt Delta primary and a 208Y/120 volt secondary for three-phase transformers; 240 x 480 volt primary and a 120/240 volt secondary for single-phase transformers. All data is subject to future revision. Note: Refer to the Cutler-Hammer business for 5 kV class information. All data is subject to future revision. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose & Industrial Control Transformers 9-127 November 2003 Technical Data and Specifications Vol. 1, Ref. No. [0427] Typical Dimensions and Technical Data Table 9-151. Typical Data for 600-Volt Class NEMA TP-1 and Non-linear Transformers Type DT-3 150ºC Rise NEMA TP-1 K-4 150°C Rise K-4 115°C Rise K-4 80°C Rise K-13 150°C Rise K-13 115°C Rise K-13 80°C Rise kVA 15 30 45 75 112.5 150 225 300 500 15 30 45 75 112.5 150 225 300 500 15 30 45 75 112.5 150 225 300 500 15 30 45 75 112.5 150 225 300 500 15 30 45 75 112.5 150 225 300 500 15 30 45 75 112.5 150 225 300 500 15 30 45 75 112.5 150 225 300 Dimensions (Inches) Height Width Depth Weight Lbs. Al Cu 25 30-1/8 30-1/8 39-3/8 39-3/8 46-1/2 56 62-1/4 75 30-1/8 30-1/8 30-1/8 39-3/8 39-3/8 56 56 75 75 30-1/8 30-1/8 39-3/8 39-3/8 46-5/8 56 62-1/4 75 90 30-1/8 30-1/8 39-3/8 39-3/8 56 56 62-1/4 75 20-1/8 20-1/8 20-1/8 26-1/8 26-1/8 28 31-1/4 31-1/4 44-1/2 20-1/8 20-1/8 20-1/8 26-1/8 26-1/8 31-1/4 31-1/4 44-1/2 44-1/2 20-1/8 20-1/8 26-1/8 26-1/8 28 31-1/4 31-1/4 44-1/2 69 20-1/8 20-1/8 26-1/8 26-1/8 31-1/4 31-1/4 31-1/4 44-1/2 14-1/8 14-1/8 14-1/8 19-1/8 19-1/8 23 24-1/4 30-1/4 36 14-1/8 14-1/8 14-1/8 19-1/8 19-1/8 24-1/4 24-1/4 36 36 14-1/8 14-1/8 19-1/8 19-1/8 23 24-1/4 30-1/4 36 42 14-1/8 14-1/8 19-1/8 19-1/8 24-1/4 24-1/4 30-1/4 36 152 230 310 480 600 800 1250 1600 2400 230 230 310 480 600 1100 1100 2400 2800 230 230 480 600 785 1100 1600 2400 4500 230 310 480 600 1100 1100 1600 2400 172 300 370 550 675 1000 1800 2150 3100 300 300 370 675 675 1200 1200 3100 3600 300 300 575 675 870 1200 2150 3100 30-1/8 30-1/8 39-3/8 39-3/8 46-5/8 56 62-1/4 75 90 30-1/8 30-1/8 39-3/8 39-3/8 46-5/8 56 62-1/4 75 90 30-1/8 30-1/8 39-3/8 46-5/8 56 62-1/4 75 75 20-1/8 20-1/8 26-1/8 26-1/8 28 31-1/4 31-1/4 44-1/2 69 20-1/8 20-1/8 26-1/8 26-1/8 28 31-1/4 31-1/4 44-1/2 69 20-1/8 20-1/8 26-1/8 28 31-1/4 31-1/4 44-1/2 44-1/2 14-1/8 14-1/8 19-1/8 19-1/8 23 24-1/4 30-1/4 36 42 14-1/8 14-1/8 19-1/8 19-1/8 23 24-1/4 30-1/4 36 42 14-1/8 14-1/8 19-1/8 23 24-1/4 30-1/4 36 36 230 310 480 600 785 1100 1600 2400 4500 230 310 480 600 785 1100 1600 2400 4500 230 310 480 785 1100 1600 2400 — 300 370 575 675 870 1200 2150 3100 300 370 575 675 1200 1200 2150 3100 300 370 575 675 870 1200 2150 3100 300 370 575 870 1200 2150 3100 3600 Losses in Watts N.L. Total Efficiency 1/4 1/2 Load Load 3/4 Load Full Load % Regulation 100% 80% % Imp. P.F. P.F. 80 100 170 230 360 480 565 730 1350 250 250 300 400 600 900 900 1100 1500 250 250 400 600 700 900 1100 1500 2600 250 300 400 600 900 900 1100 1500 822 1674 1885 2534 3290 3552 6783 7477 8031 1090 1990 2110 2840 3870 5250 7270 8420 9620 950 1840 2090 2360 3760 4260 4620 4980 5360 670 990 1170 2290 2610 3090 4320 5060 98.6 97.3 97.5 98 98 98.2 98.3 98.4 98.5 92.2 95.2 96.3 97.0 97.1 96.8 97.6 97.9 98.5 92.4 95.4 95.8 96.2 96.8 97.0 97.6 97.8 97.7 92.8 95.4 96.0 96.2 96.4 97.2 97.6 97.8 96.3 96.7 97.2 97.7 97.9 98.2 98 98.3 98.7 93.5 95.3 96.5 97.1 97.3 97.1 97.6 97.9 98.8 93.9 95.5 96.7 96.9 97.2 97.4 98.1 98.5 98.4 94.7 96.5 97.0 97.0 97.3 97.8 98.1 98.5 95.4 95.6 96.5 97.1 97.4 97.8 97.5 97.9 98.5 92.9 94.3 95.8 96.6 96.8 96.7 97.1 97.5 98.7 93.5 94.6 96.4 96.7 96.8 97.2 98.0 98.5 98.5 94.7 96.3 97.0 96.8 97.3 97.7 98.0 98.6 94.3 94.4 95.6 96.4 96.9 97.4 96.8 97.3 98.2 91.8 93.0 94.9 95.9 96.2 96.1 96.5 96.9 98.5 92.6 93.5 95.9 96.2 96.2 96.7 97.7 98.4 98.4 94.2 95.9 96.6 96.3 97.0 97.4 97.6 98.6 3.3 3.6 2.7 2.1 2.3 1.6 2.3 1.9 1.4 3.5 3.7 2.6 2.3 2.8 2.2 1.1 1.6 .7 3.3 3.6 1.9 2.1 2.8 1.9 1.4 .8 .7 2.0 1.8 3.1 1.8 1.4 1.4 1.7 .7 4.8 5.1 4.4 4.3 4.6 3.8 6.4 5.7 4.9 5.1 6.0 4.3 4.3 5.5 4.2 4.1 5.6 3.7 4.4 5.7 3.1 3.8 4.9 3.9 4.1 2.4 4.1 3.1 2.7 3.2 3.5 2.9 3.7 4.6 2.4 6.4 7 5.9 5.7 5.9 5.3 8.4 7.6 6.4 5.2 6.3 4.5 4.8 6.2 4.7 5.3 7.7 5.5 4.4 5.9 3.2 4.2 5.4 4.5 5.3 3.0 6.1 3.1 2.8 3.3 3.9 3.3 4.6 5.9 3.2 250 300 400 600 700 900 1100 1500 2600 250 300 400 600 700 900 1100 1500 2600 250 300 400 700 900 1100 1500 2100 900 1370 1730 2270 3370 4270 5080 5310 5625 790 1070 1300 1960 3140 3480 4200 4780 5360 690 990 1120 1800 2210 2350 2470 2860 92.5 95.1 95.7 96.2 96.9 97.0 97.5 97.7 97.7 92.6 95.3 95.9 96.3 96.9 97.1 97.6 97.8 97.7 92.7 95.4 96.0 95.8 96.4 96.8 97.1 97.1 94.1 95.9 96.4 97.0 97.3 97.4 97.9 98.4 98.4 94.4 96.4 96.9 97.2 97.4 97.7 98.1 98.5 98.4 94.7 96.5 97.1 97.0 97.5 97.8 98.2 98.2 93.7 95.5 96.1 96.8 97.0 97.1 97.7 98.4 98.5 94.2 96.1 96.8 97.1 97.2 97.5 98.0 98.5 98.5 94.6 96.3 97.0 97.0 97.5 97.9 98.3 98.4 92.9 94.7 95.5 96.3 96.5 96.7 97.3 98.3 98.4 93.5 95.6 96.4 96.7 96.7 97.2 97.7 98.4 98.4 94.1 95.9 96.7 96.8 97.3 97.8 98.3 98.4 2.5 2.3 2.0 3.5 2.5 1.8 1.7 .9 .6 2.4 1.8 1.6 1.8 1.7 1.5 1.6 .8 .7 2.3 1.8 1.4 1.6 1.1 .9 .6 .7 3.9 3.6 3.1 4.0 4.6 3.8 4.2 2.5 3.3 3.5 2.4 3.0 3.3 3.5 3.8 4.2 2.4 3.3 3.3 2.7 2.7 3.0 2.7 2.6 2.0 2.8 4.1 3.7 3.2 4.0 5.1 4.4 5.2 3.2 4.7 3.6 2.4 3.3 3.6 4.8 4.6 5.3 3.1 4.7 3.4 2.8 3.0 3.3 3.4 3.4 2.5 3.8 Sound Level dB 45 45 45 50 50 50 55 55 60 45 45 45 50 50 55 55 55 60 45 45 45 50 50 50 55 55 60 45 45 45 50 50 50 55 55 60 45 45 45 50 50 50 55 55 60 45 45 45 50 50 50 55 55 60 45 45 45 50 50 50 55 55 Typical values for aluminum windings. Contact Eaton’s Cutler-Hammer business for values of copper windings. For Type DT-3 transformers and all K Factor transformers, allow 6-inch (152.4 mm) clearance between rear of transformer and wall. Actual impedance may be ± 7.5%. Refer to the Cutler-Hammer business. Note: Performance data is based upon 480 volt Delta primary and a 208Y/120 volt secondary for three-phase transformers; 240 x 480 volt primary and a 120/240 volt secondary for single-phase transformers. All data is subject to future revision. Note: Performance Data is based on a 480 delta primary and a 208Y/120 secondary. All data is subject to future revision. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 Transformers General Purpose & Industrial Control Transformers 9-128 November 2003 Technical Data and Specifications Vol. 1, Ref. No. [0428] Typical Specifications — General Purpose (1000 kVA and Below) General Furnish and install, single-phase and three-phase general purpose individually mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. Transformers shall be manufactured by Eaton’s CutlerHammer business. 9 Transformers shall be designed, manufactured, and tested in accordance with all the latest applicable ANSI, NEMA and IEEE standards. All 600-volt class transformers through 1000 kVA shall be UL listed and bear the UL label. Transformers shall be designed for continuous operation at rated kVA, for 24 hours a day, 365 days a year operation, with normal life expectancy as defined in ANSI C57.96. Insulation Systems Transformers shall be insulated as follows: ■ Type EP or EPT: 0.050 through 75 kVA: 185°C insulation system. ■ Type DS-3 or DT-3: 15 kVA and above: 220°C (Class R) insulation system. Required performance shall be obtained without exceeding the above indicated temperature rise in a 40°C maximum ambient, with a 30°C average over 24 hours. All insulation materials shall be flameretardant and shall not support combustion as defined in ASTM Standard Test Method D635. Core and Coil Assemblies Transformer core shall be constructed with high grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Coils shall be wound of electrical grade [aluminum] [copper] and continuous wound construction. BIL (Basic Impulse Level) for all 600volt class windings shall be 10 kV. Cutler-Hammer Family of Dry-Type Distribution Transformers On encapsulated units rated [75 kVA and below] [15 kVA and below] [9 kVA and below] the core and coil assembly shall be completely encapsulated in a proportioned mixture of resin and aggregate to provide a moistureproof, shock resistant seal. The core and coil encapsulation system shall minimize the sound level. On ventilated units rated [15 kVA and above] [30 kVA and above] [112.5 kVA and above] the core and coil assembly shall be impregnated with nonhygroscopic, thermosetting varnish and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads. Enclosures The enclosure shall be made of heavy gauge steel and shall be finished utilizing a continuous process of degreasing, cleaning, and phosphatizing, followed by electrostatic deposition of a thermosetting polyester powder coating and subsequent baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. The maximum temperature on top of the enclosure shall not exceed 90°C. provide suitable weathershields over ventilation openings. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall or structure. Sound Levels Transformer average sound levels shall not exceed the following ANSI and NEMA levels for self-cooled ratings measured in accordance with NEMA ST-20. Table 9-152. Average Sound Levels NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Tests The following tests shall be performed as standard on all transformers: 1. Ratio tests at the rated voltage connection and at all tap connections. On units rated [75 kVA and below] [15 kVA and below] [9 kVA and below] encapsulated the enclosure construction shall be totally enclosed, nonventilated, NEMA 3R, with lifting provisions. 2. Polarity and phase relation tests on the rated voltage connection. On units rated [15 kVA and above] [30 kVA and above] [112.5 kVA and above] the enclosure construction shall be ventilated, NEMA 2, dripproof, with lifting provisions. All ventilation openings shall be protected against falling dirt. On outdoor units, 5. No-load and excitation current at rated voltage on the rated voltage connection. For more information visit: www.cutler-hammer.eaton.com 3. Applied potential tests. 4. Induced potential test. CA08101001E Transformers General Purpose & Industrial Control Transformers 9-129 November 2003 Technical Data and Specifications Vol. 1, Ref. No. [0429] Typical Specifications — Dry-Type Transformers for Non-Linear Loads General Furnish and install, individually mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. Transformers shall be manufactured by Eaton’s Cutler-Hammer business. Transformers shall be designed, manufactured, and tested in accordance with all the latest applicable ANSI, NEMA and IEEE standards. All 600-volt class transformers through 500 kVA shall be UL listed as suitable for non-sinusoidal current loads with K factor not to exceed [4] [13] [20]. Insulation Systems Transformers shall be insulated with a UL recognized 220°C (Class R) insulation system. Winding temperature rise shall be (80°C) (115°C) (150°C). Required performance shall be obtained without exceeding the above indicated temperature rise in a 40°C maximum ambient, with a 30°C average. All insulation materials shall be flameretardant and shall not support combustion as defined in ASTM Standard Test Method D635. Core and Coil Assemblies Transformer core shall be constructed with high grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Transformer coils shall be wound of electrical grade [aluminum] [copper] conductor with continuous wound construction. An electrostatic shield consisting of a single turn of aluminum shall be placed between the primary and secondary winding and grounded to the transformer core. BIL (Basic Impulse Level) for all 600-volt class windings shall be 10 kV. The core and coil assembly shall be impregnated with non-hygroscopic, thermosetting varnish and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads. The neutral conductor shall be rated to carry 200% of normal phase current. Sound Levels Transformer average sound levels shall not exceed the following ANSI and NEMA levels for self-cooled ratings measured in accordance with NEMA ST-20. Table 9-153. Average Sound Levels NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 The enclosure construction shall be ventilated, NEMA 2, drip-proof, with lifting provisions. All ventilation openings shall be protected against falling dirt. On outdoor units, provide suitable weathershields over ventilation openings. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall or structure. Non-Linear Ratings The transformers shall be specifically designed to supply circuits with a harmonic profile equal to or less than a K Factor of 4 or 13 as described below without exceeding [80°C] [115°C] [150°C] temperature rise. 9 Table 9-154. Non-Linear Ratings Harmonic K-4 K-13 Fundamental 3rd 5th 100.0% 34.0% 22.0% 100.0% 70.0% 42.0% 7th 9th 11th 3.0% 1.0% .7% 5.0% 3.0% 3.0% 13th 15th 17th .5% .3% .3% 1.0% .7% .6% Tests The following tests shall be performed as standard on all transformers: 1. Ratio tests at the rated voltage connection and at all tap connections. 2. Polarity and phase relation tests on the rated voltage connection. 3. Applied potential tests. 4. Induced potential test. 5. No-load and excitation current at rated voltage on the rated voltage connection. Enclosures The enclosure shall be made of heavy gauge steel and shall be finished utilizing a continuous process of degreasing, cleaning, and phosphatizing, followed by electrostatic deposition of a polymer polyester powder coating and baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. The maximum temperature on top of the enclosure shall not exceed 90°C. CA08101001E For more information visit: www.cutler-hammer.eaton.com Further Information . . . . . . . . . . . . . B.36B.01.S.E For a complete product specification in CSI format, see the Cutler-Hammer Product Specification Guide . . . . . Section 16462 9-130 Transformers General Purpose & Industrial Control Transformers November 2003 Technical Data and Specifications Typical Specifications — Low Temperature Rise Energy Efficient General Furnish and install, three-phase low temperature rise energy efficient drytype transformers of the two-winding type, self-cooled, with ratings (kVA) as indicated on the drawings. Transformers shall be manufactured by Eaton’s Cutler-Hammer business. 9 Transformers shall be designed, manufactured, and tested in accordance with all applicable ANSI/NEMA and IEEE standards, and shall be listed by Underwriters Laboratories, Inc. and bear the UL label. Transformers shall be designed for continuous operation at rated kVA, 24 hours a day, 365 days a year, with normal life expectancy as defined in ANSI C57.96. Insulation System and Temperature Rise Transformers shall be insulated with a 220°C (Class R) insulation system. Transformers shall be 115°C rise (80°C rise) and shall be capable of carrying a 15% continuous overload, (80°C rise transformers a continuous 30% overload) without exceeding a 150°C rise. Required performance shall be obtained without exceeding the above rise in a 40°C maximum, 30°C average ambient temperature. All insulation materials shall be flameretardant and shall not support combustion as defined in ASTM Standard Test Method D635. Vol. 1, Ref. No. [0430] Core and Coil Assemblies Sound Levels Transformer core shall be constructed with high grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Coils shall be wound of electrical grade [aluminum] [copper] with continuous wound construction. BIL (Basic Impulse Level) for all 600-volt class windings shall be 10 kV. Transformer average sound levels shall not exceed the following ANSI/NEMA levels for self-cooled ratings measured in accordance with NEMA ST-20. The core and coil assembly shall be impregnated with non-hygroscopic, thermosetting varnish and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads. Enclosures The enclosure shall be made of heavy gauge steel and shall be finished utilizing a continuous process of degreasing, cleaning, and phosphatizing, followed by electrostatic deposition of a polymer polyester powder coating and subsequent baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. Table 9-155. Average Sound Levels NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Tests The following tests shall be performed as standard on all transformers: 1. Ratio tests at the rated voltage connection and at all tap connections. 2. Polarity and phase relation tests on the rated voltage connection. 3. Applied potential tests. 4. Induced potential test. 5. No-load and excitation current at rated voltage on the rated voltage connection. The enclosure construction shall be ventilated, NEMA 2, drip-proof, with lifting provisions. All ventilation openings shall be protected against falling dirt. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall or structure. All transformers shall be equipped with a wiring compartment suitable for conduit entry and large enough to allow convenient wiring. The maximum temperature on top of the enclosure shall not exceed 90°C. For a complete product specification in CSI format, see the Cutler-Hammer Product Specification Guide . . . . . Section 16461 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose & Industrial Control Transformers 9-131 November 2003 Vol. 1, Ref. No. [0431] Typical Specifications — Isolation Transformers with Electrostatic Shielding General Furnish and install, single-phase and three-phase general purpose individually mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. Transformers shall be manufactured by Eaton’s CutlerHammer business. Transformers shall be designed, manufactured, and tested in accordance with all the latest applicable ANSI, NEMA and IEEE standards. All 600-volt class transformers through 1000 kVA shall be UL listed and bear the UL label. Transformers shall be designed for continuous operation at rated kVA, for 24 hours a day, 365 days a year operation, with normal life expectancy as defined in ANSI C57.96. Insulation Systems Transformers shall be insulated as follows: ■ Type EP or EPT: 0.050 through 75 kVA: 185°C insulation system which superseded Class F, based on 115°C rise. ■ Type DS-3 or DT-3: 15 kVA and above: 220°C (Class R) insulation system which superseded Class H, based on 150°C rise. Required performance shall be obtained without exceeding the above indicated temperature rise in a 40°C maximum ambient. All insulation materials shall be flameretardant and shall not support combustion as defined in ASTM Standard Test Method D635. CA08101001E Technical Data and Specifications Core and Coil Assemblies Transformer core shall be constructed with high grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Transformer coils shall be wound of electrical grade aluminum and continuous wound construction. An electrostatic shield consisting of a single turn of [aluminum] [copper] shall be placed between the primary and secondary winding and grounded to the transformer core. BIL (Basic Impulse Level) for all 600-volt class windings shall be 10 kV. On units rated [75 kVA and below] [15 kVA and below] [9 kVA and below] the core and coil assembly shall be completely encapsulated in a proportioned mixture of resin and aggregate to provide a moistureproof, shock resistant seal. The core and coil encapsulation system shall minimize the sound level. On units rated [15 kVA and above] [30 kVA and above] [112.5 kVA and above] the core and coil assembly shall be impregnated with nonhygroscopic, thermosetting varnish and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads. Enclosures The enclosure shall be made of heavy gauge steel and shall be finished utilizing a continuous process of degreasing, cleaning, and phosphatizing, followed by electrostatic deposition of a thermosetting polyester powder coating and baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. The maximum temperature on top of the enclosure shall not exceed 90°C. For more information visit: www.cutler-hammer.eaton.com On units rated [75 kVA and below] [15 kVA and below] [9 kVA and below] encapsulated, the enclosure construction shall be totally enclosed, nonventilated, NEMA 3R, with lifting provisions. On units rated [15 kVA and above] [30 kVA and above] [112.5 kVA and above] the enclosure construction shall be ventilated, NEMA 2, drip-proof, with lifting provisions. All ventilation openings shall be protected against falling dirt. On outdoor units, provide suitable weathershields over ventilation openings. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall or structure. 9 Sound Levels Transformer average sound levels shall not exceed the following ANSI and NEMA levels for self-cooled ratings measured in accordance with NEMA ST-20. Table 9-156. Average Sound Levels NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Tests The following tests shall be performed as standard on all transformers: 1. Ratio tests at the rated voltage connection and at all tap connections. 2. Polarity and phase relation tests on the rated voltage connection. 3. Applied potential tests. 4. Induced potential test. 5. No-load and excitation current at rated voltage on the rated voltage connection. 9-132 Transformers General Purpose & Industrial Control Transformers November 2003 Technical Data and Specifications Typical Specification — ac Adjustable Frequency Drive Isolation Transformers General Furnish and install, single-phase and three-phase general purpose individually mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages for input application as indicated on the drawings. Transformers shall be manufactured by Eaton’s Cutler-Hammer business. 9 Transformers shall be designed, manufactured, and tested in accordance with all the latest applicable ANSI, NEMA and IEEE standards. All 600-volt class transformers through 550 kVA shall be UL listed and bear the UL label. Transformers shall be designed for continuous operation at rated kVA, for 24 hours a day, 365 days a year operation, with normal life expectancy as defined in ANSI C57.96. Insulation Systems Transformers shall be insulated with a UL recognized 220°C (Class R) insulation system. Required performance shall be obtained without exceeding the above indicated temperature rise in a 40°C maximum ambient, with a 30°C average over 24 hours. All insulation materials shall be flameretardant and shall not support combustion as defined in ASTM Standard Test Method D635. Vol. 1, Ref. No. [0432] Core and Coil Assemblies Sound Levels Transformer core shall be constructed with high grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Coils shall be wound of electrical grade [aluminum] [copper] and continuous wound construction. BIL (Basic Impulse Level) for all 600volt class windings shall be 10 kV. Transformer average sound levels shall not exceed the following ANSI and NEMA levels for self-cooled ratings measured in accordance with NEMA ST-20. A temperature sensing device shall be imbedded in the center coil. The core and coil assembly shall be impregnated with non-hygroscopic, thermosetting varnish and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads. Enclosures The enclosure shall be made of heavy gauge steel and shall be finished utilizing a continuous process of degreasing, cleaning, and phosphatizing, followed by electrostatic deposition of a thermosetting polyester powder coating and subsequent baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. The maximum temperature on top of the enclosure shall not exceed 90°C. The enclosure construction shall be ventilated, NEMA 2, drip-proof, with lifting provisions. All ventilation openings shall be protected against falling dirt. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall or structure. On outdoor units, provide suitable weathershields over ventilation openings. Table 9-157. Average Sound Levels NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 The following table lists the recommended kVA size of the drive isolation transformer for a specific horsepower requirement. Table 9-158. Three-Phase Horsepower ac Motor kVA Minimum 5 7.5 10 7.5 11 14 15 20 25 20 27 34 30 40 50 40 51 63 60 75 100 75 93 118 125 150 200 145 175 220 250 300 400 275 330 440 500 600 700 550 660 770 For a complete product specification in CSI format, see the Cutler-Hammer Product Specification Guide . . . . . Section 16461 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose & Industrial Control Transformers 9-133 November 2003 Vol. 1, Ref. No. [0433] Technical Data and Specifications Typical Specifications — Mini-Power Centers (3 – 30 kVA) General Furnish and install, single-phase and three-phase general purpose individually mounted mini-power centers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. Mini-power centers shall be manufactured by Eaton’s CutlerHammer business. Units shall be designed, manufactured, and tested in accordance with all the latest applicable ANSI, NEMA, IEEE, CSA and UL standards, and shall be UL listed and CSA certified and bear the UL and CSA labels. Units shall be designed for continuous operation at rated kVA, 24 hours a day, 365 days a year operation, with normal life expectancy as defined in ANSI C57.96. Each mini-power center shall include a main primary breaker with an interrupting rating of 14 kA at 277/480 volts; an encapsulated dry-type transformer and a secondary panelboard with main breaker rated 10 kA interrupting rating at 120/240 volts. a. All interconnecting wiring between the primary breaker and transformer, secondary main breaker and transformer, and distribution section shall be factory installed. Main primary, secondary and feeder breakers shall be enclosed with a padlockable hinged door. b. The secondary distribution section shall accommodate one inch, plug-in breakers with 10 kA interrupting capacity. Insulation System Transformers shall be insulated with a 185°C insulation system. Required performance shall be obtained without exceeding the above indicated temperature rise in a 40°C maximum ambient, with a 30°C average over 24 hours. All insulation materials shall be flameretardant and shall not support combustion as defined in ASTM Standard Test Method D635. Core and Coil Assemblies Transformer core shall be constructed with high grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. CA08101001E 9 Mini-Power Center The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Coils shall be wound of electrical grade aluminum with continuous wound construction. BIL (Basic Impulse Level) for all 600-volt class windings shall be 10 kV. The core and coil assembly shall be completely encapsulated in a proportioned mixture of resin and aggregate to provide a moistureproof, shock resistant seal. The core and coil encapsulation system shall minimize the sound level. Enclosures The enclosure shall be made of heavy gauge steel and shall be finished utilizing a continuous process of degreasing, cleaning, and phosphatizing, followed by electrostatic deposition of a thermosetting polymer polyester powder coating and subsequent baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. Mini-power centers shall be equipped with a wiring compartment suitable for conduit entry and large enough to allow convenient wiring. The maximum temperature on top of the enclosure shall not exceed 90°C. The core of the transformer shall be grounded to the enclosure. The enclosure shall be totally enclosed, nonventilated, NEMA 3R, with lifting eyes. For more information visit: www.cutler-hammer.eaton.com Sound Levels Transformer average sound levels shall not exceed the following ANSI/NEMA levels for self-cooled ratings measured in accordance with NEMA ST-20. Table 9-159. Average Sound Levels kVA NEMA Average Sound Level in dB 0–9 10 – 30 45 50 Tests The following tests shall be performed as standard on all transformers: 1. Ratio tests at the rated voltage connection and at all tap connections. 2. Polarity and phase relation tests on the rated voltage connection. 3. Applied potential tests. 4. Induced potential test. 5. No-load and excitation current at rated voltage on the rated voltage connection. 9-134 Transformers General Purpose & Industrial Control Transformers November 2003 Technical Data and Specifications Typical Specification –— NEMA TP-1-1996 Compliant Energy Efficient Transformers Core and Coil Assemblies Enclosures Furnish and install, three-phase energy efficient dry-type transformers that comply with NEMA Standard TP-1-1996. Transformers shall be of the two-winding type, self-cooled, with ratings (kVA) as indicated on the drawings. Transformer’s losses shall conform to NEMA TP-1 requirements. Transformers shall bear the Energy Star® label and be manufactured by Eaton’s Cutler-Hammer business. Transformer core shall be constructed with high grade, non-aging, silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Maximum magnetic flux densities shall be substantially below the saturation point. The transformer core volume shall allow efficient transformer operation at 10% above the nominal tap voltage. The core laminations shall be tightly clamped and compressed. Coils shall be wound of electrical grade [aluminum] [copper] and continuous wound construction. BIL (Basic Impulse Level) for all 600volt class windings shall be 10 kV. The enclosure shall be made of heavy gauge steel and shall be finished utilizing a continuous process of degreasing, cleaning, and phosphatizing, followed by electrostatic deposition of a thermosetting polyester powder coating and subsequent baking. The coating color shall be ANSI 61 and shall be UL recognized for outdoor use. Transformers shall be designed, manufactured, and tested in accordance with all the latest applicable ANSI, NEMA and IEEE standards, and shall be listed by Underwriters Laboratories and bear the UL label. The core and coil assembly shall be impregnated with non-hygroscopic, thermosetting varnish and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads. Transformers shall be designed for continuous operation at rated kVA, for 24 hours a day, 365 days a year, with normal life expectancy as defined in ANSI C57.96. Efficiency Insulation System and Temperature Rise Table 9-160. NEMA TP-1-1996 Efficiency Levels General 9 Vol. 1, Ref. No. [0434] Transformers shall be insulated with a 220°C (Class R) insulation system. Transformers shall be 150°C rise and shall be capable of carrying a 15% continuous overload without exceeding a 150°C rise. Required performance shall be obtained without exceeding the above rise in a 40°C maximum, 30°C average ambient temperature. All insulation materials shall be retardant and shall not support combustion as defined in ASTM Standard Test Method D635. Transformers shall be energy efficient with minimum efficiencies as set forth per NEMA TP-1-1996 when operated at 35% of full load capacity. Tables of Energy Efficiency NEMA Class 1 Efficiency Levels dry-type Distribution Transformers — Low Voltage Single-Phase kVA All transformers shall be equipped with a wiring compartment suitable for conduit entry and large enough to allow convenient wiring. The maximum temperature on top of the enclosure shall not exceed 90°C. Sound Levels Transformer average sound levels shall not exceed the following ANSI and NEMA levels for self-cooled ratings. Table 9-161. Average Sound Levels NEMA ST-20 Average Sound Level (dB) kVA Ventilated Encapsulated 0–9 10 – 50 51 – 150 151 – 300 40 45 50 55 45 50 55 57 301 – 500 501 – 700 701 – 1000 1001 – 1500 60 62 64 65 59 61 63 64 Three-Phase Efficiency kVA Efficiency 97.7 98.0 98.2 15 30 45 97.0 97.5 97.7 50 75 100 98.3 98.5 98.6 75 112.5 150 98.0 98.2 98.3 167 250 333 — — 98.7 98.8 98.9 — — 15 25 37.5 The enclosure construction shall be ventilated, NEMA 2, drip-proof, with lifting provisions. All ventilation openings shall be protected against falling dirt. To ensure proper ventilation, locate the unit at least 6 inches (152.4 mm) from the adjacent wall or structure. 225 300 500 750 1000 98.5 98.6 98.7 98.8 98.9 Tests The following tests shall be performed as standard on all transformers: 1. Ratio tests at the rated voltage connection and at all tap connections. 2. Polarity and phase relation tests on the rated voltage connection. 3. Applied potential tests. 4. Induced potential test. 5. No-load and excitation current at rated voltage on the rated voltage connection. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose & Industrial Control Transformers 9-135 November 2003 Technical Data and Specifications Vol. 1, Ref. No. [0435] Standards and Certification Cutler-Hammer Dry-Type Distribution Transformers by Eaton Corporation are approved, listed, recognized or may comply with the following standards. Table 9-162. Engineering Standards Catalog Product Name UL Standard UL/cUL File Number UL Listed Control Number cUL Energy Efficiency File Number CSA File Number Insulation System Temp/ºC kVA SinglePhase kVA ThreePhase Applicable IEC Standard Industrial Control Transformer MTA 506 E10156 591H — LR60545 105 .05 – 5 N/A 61558 MTC 506 E10156 591H — LR60545 105 .05 – 5 N/A 61558 MTE 506 E46323 702X — LR27533 105 .025 – 1.5 N/A 61558 MTG 506 E46323 702X — LR27533 105 .05 – 1.0 N/A 61558 MTK 506 E46323 702X — LR27533 180 .05 – 5 N/A 61558 Encapsulated Transformer AP 506 E10156 591H — — 180 3 – 10 N/A 61558 AP 1561 E78389 591H — — 180 15 N/A 61558 EP 506 E10156 591H — LR60545 180 .05 – 10 N/A 61558 LR60545 N/A 61558 /726 EP 1561 E78389 591H EV157 180 15 – 50 EPT 506 E10156 591H — LR60545 180 N/A 3–9 61558 /726 EPT 1561 E78389 591H EV157 LR60545 180 N/A 15 – 75 726 506 /1561 E53449 591H — LR60546 180 3 – 25 15 – 30 — MPC Ventilated Transformer DS-3 1561 E78389 591H EV157 LR60545 220 15 – 167 N/A 60726 DT-3 1561 E78389 591H EV157 LR60545 220 N/A 15 – 750 60726 KT 1561 E78389 591H EV157 — 220 N/A 9 – 500 N/A Applies to .05 – 1 kVA. Applies to 25 – 50 kVA. Applies to 25 kVA. Applies to 15 – 25 kVA. Applies to 37.5 kVA. Applies to 3 kVA. Applies to 5 – 9 kVA. Applies to 30 – 75 kVA. Applies to 30 kVA. Applies to 3 – 10 kVA. Applies to 15 – 30 kVA. Applies to 25 – 167 kVA. Applies to 30 – 750 kVA. Applies to 30 – 500 kVA. In addition to the above standards, Cutler-Hammer Dry-Type Distribution transformers are also manufactured in compliance with the applicable standards listed below. Note: Not all of the following standards apply to every transformer. ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ NEC: National Electrical Code. NEMA ST-1: Specialty Transformers (C89.1) (control transformers). NEMA ST-20: General Purpose Transformers. NEMA TP-1: Guide for Determining Energy Efficiency for Distribution Transformers. NEMA 250: Enclosures for Electrical Equipment (1000 volts maximum). IEEE C57.12.01: General Requirements for Dry-Type Distribution and Power Transformers (including those with solid-cast and/or resin-encapsulated windings). ANSI C57.12.70: Terminal Markings and Connections for Distribution and Power Transformers. ANSI C57.12.91: Standard Test Code for Dry-Type Distribution and Power Transformers. CSA C22 No. 47-M90: Air-Cooled Transformers (Dry-Type). CSA C9-M1981: Dry-Type Transformers. CSA C22.2 No. 66: Specialty Transformers. CSA 802-94: Maximum Losses for Distribution, Power, and Dry-Type Transformers. NEMA TP-2: Standard Test Method for Measuring the Energy Consumption of Distribution Transformers. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 9-136 Transformers General Purpose & Industrial Control Transformers November 2003 Technical Data and Specifications Product Selection Vol. 1, Ref. No. [0436] Table 9-163. Single-Phase ac Motors Horsepower Full Load Amperes Single-Phase Transformers 115 Volts kVA = Volts x Amperes 1000 — If the load is an ac motor, determine the minimum transformer kVA from the chart at the right. — Select a transformer rating equal to or greater than the load kVA. 4. Define tap arrangements needed. 5. Define temperature rise. Using the above procedure, select the transformer from the listings in this catalog. Minimum Transformer kVA 2.4 3.2 4.0 2.3 3.0 3.8 2.2 2.9 3.6 .53 .70 .87 1/2 3/4 1 9.8 13.8 16 5.4 7.6 8.8 5.1 7.2 8.4 4.9 6.9 8 1.18 1.66 1.92 1-1/2 2 3 20 24 34 11.0 13.2 18.7 10.4 12.5 17.8 10 12 17 2.40 2.88 4.10 5 7-1/2 10 56 80 100 30.8 44 55 29.3 42 52 28 40 50 6.72 9.6 12.0 2. Determine the secondary (load) voltage — the voltage needed at the load. — If the load rating is given in amperes, determine the load kVA from the below chart. To determine kVA when volts and amperes are known, use the formula: 230 Volts 4.4 5.8 7.2 1. Determine the primary (source) voltage — the voltage presently available. 9 220 Volts 1/6 1/4 1/3 How to Select Single-Phase Units 3. Determine the kVA load: — If the load is defined in kVA, a transformer can be selected from the tabulated data. 208 Volts If motors are started more than once per hour, increase minimum transformer kVA by 20%. Note: When motor service factor is greater than 1, increase full load amperes proportionally. Example: If service factor is 1.15, increase above ampere values by 15%. Table 9-164. Full Load Current in Amperes — Single-Phase Circuits kVA Voltage 120 2400 4160 2.0 4.2 6.3 1.2 2.4 3.6 1.1 2.3 3.4 1.0 2.1 3.1 .9 1.8 2.7 .5 1.0 1.6 .4 .8 1.3 .10 .21 .31 .06 .12 .18 1 1.5 2 8.3 12.5 16.7 4.8 7.2 9.6 4.5 6.8 9.1 4.2 6.2 8.3 3.6 5.4 7.2 2.1 3.1 4.2 1.7 2.5 3.3 .42 .63 .83 .24 .36 .48 3 5 7.5 25 41 62 14.4 24.0 36 13.6 22.7 34 12.5 20.8 31 10.8 18.0 27 6.2 10.4 15.6 5.0 8.3 12.5 1.2 2.1 3.1 .72 1.2 1.8 20.8 31 52 16.7 25 41 4.2 6.2 10.4 2.4 3.6 6.0 .25 .50 .75 208 220 240 277 480 600 10 15 25 83 125 208 48 72 120 45 68 114 41 62 104 36 54 90 37.5 50 75 312 416 625 180 240 360 170 227 341 156 208 312 135 180 270 78 104 156 62 83 125 15.6 20.8 31.3 9.0 12.0 18.0 833 1391 480 802 455 759 416 695 361 602 208 347 166 278 41.7 69.6 24.0 40.1 100 167 For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose & Industrial Control Transformers 9-137 November 2003 Technical Data and Specifications Vol. 1, Ref. No. [0437] Three-Phase Transformers How to Select Three-Phase Units Table 9-165. Three-Phase ac Motors Horsepower 1. Determine the primary (source) voltage — the voltage presently available. — If the load is an ac motor, determine the minimum transformer kVA from the chart at the right. — Select a transformer rating equal to or greater than the load kVA. 4. Define tap arrangements needed. 5. Define temperature rise. Using the above procedure, select the transformer from the listings in this catalog. CA08101001E 380 Volts 460 Volts 575 Volts Minimum Transformer kVA 2.2 3.1 4.0 2.0 2.8 3.6 1.2 1.7 2.2 1.0 1.4 1.8 .8 1.1 1.4 .9 1.2 1.5 1-1/2 2 3 5.7 7.5 10.7 5.2 6.8 9.6 3.1 4.1 5.8 2.6 3.4 4.8 2.1 2.7 3.9 2.1 2.7 3.8 5 7-1/2 10 16.7 24 31 15.2 22 28 9.2 14 17 7.6 11 14 6.1 9 11 6.3 9.2 11.2 15 20 25 46 59 75 42 54 68 26 33 41 21 27 34 17 22 27 16.6 21.6 26.6 30 40 50 88 114 143 80 104 130 48 63 79 40 52 65 32 41 52 32.4 43.2 52 60 75 100 170 211 273 154 192 248 93 116 150 77 96 124 62 77 99 64 80 103 125 150 200 342 396 528 312 360 480 189 218 291 156 180 240 125 144 192 130 150 200 1 3. Determine the kVA load: — If the load is defined in kVA, a transformer can be selected from the tabulated data. kVA = Volts x Amperes x 1.732 1000 230 Volts 1/2 3/4 2. Determine the secondary (load) voltage — the voltage needed at the load. — If the load rating is given in amperes, determine the load kVA from the below chart. To determine kVA when volts and amperes are known, use the formula: Full Load Amperes 208 Volts 9 If motors are started more than once per hour, increase minimum transformer kVA by 20%. Note: When motor service factor is greater than 1, increase full load amperes proportionally. Example: If service factor is 1.15, increase above ampere values by 15%. Table 9-166. Full Load Current in Amperes — Three-Phase Circuits kVA Voltage 208 240 380 480 600 2400 4160 3 6 9 8.3 16.6 25 7.2 14.4 21.6 4.6 9.1 13.7 3.6 7.2 10.8 2.9 5.8 8.6 .72 1.4 2.2 .42 .83 1.2 15 22.5 30 41.7 62.4 83.4 36.1 54.1 72.3 22.8 34.2 45.6 18.0 27.1 36.1 14.4 21.6 28.9 3.6 5.4 7.2 2.1 3.1 4.2 57.0 68.4 76 45.2 54.2 60.1 36.1 43.4 48.1 9.0 10.8 12.0 5.2 6.3 6.9 37.5 45 50 104 124 139 90.3 108 120 75 112.5 150 208 312 416 180 270 360 114 171 228 90 135 180 72 108 144 18.0 27.1 36.1 10.4 15.6 20.8 225 300 500 624 832 1387 541 721 1202 342 456 760 270 360 601 216 288 481 54.2 72.2 120 31.3 41.6 69.4 750 1000 2084 2779 1806 2408 1140 1519 903 1204 723 963 180 241 For more information visit: www.cutler-hammer.eaton.com 104 139 Transformers General Purpose & Industrial Control Transformers 9-138 November 2003 Catalog Numbering System Vol. 1, Ref. No. [0438] Catalog Numbering System Note: Contact your local Cutler-Hammer sales office for voltage combinations not shown. Use table for catalog number breakdown only. Do not use to create catalog numbers since all combinations may not be valid. Table 9-167. General Purpose, Energy Efficient, Mini-Power Center, Shielded Isolation, Non-Linear, Buck-Boost, Marine Duty Transformers — Example: S20N11S05A S 20 N 11 S 05 A Type S Y T V P Z = EP (1-Ph encapsulated) = EPT (3-Ph encapsulated) = DS-3 (1-Ph ventilated) = DT-3 (3-Ph ventilated) = Mini-Power Center = Class 1 Division 2 Groups C and D X = Harmonic Mitigating (3-ph ventilated) 9 Non-Linear H = KT-4 (3-Ph ventilated) B = KT-9 (3-Ph ventilated) N = KT-13 (3-Ph ventilated) G = KT-20 (3-Ph ventilated) J = KT-30 (3-Ph ventilated) A = KT-40 (3-Ph ventilated) K = KT-50 (3-Ph ventilated) HT = KT-4 (1-Ph ventilated) NT= KT-13 (1-Ph ventilated) GT= KT-20 (1-Ph ventilated) Marine Duty Q = EPM Marine (1-Ph encapsulated) L = EPTM Marine (3-Ph encapsulated) R = DS-3M Marine (1-Ph ventilated) M = DT-3M Marine (3-Ph ventilated) Primary Voltage 13 12 10 29 72 25 23 24 20 27 38 39 43 44 45 48 57 60 42 46 49 40 = 110 x 220 = 120 = 120 x 240 = 208 = 200 = 220 = 230 = 240 = 240 x 480 = 277 = 380 = 400 = 416 = 440 = 450 = 480 = 575 = 600 = 2400 = 4160 = 4800 = Export Model D E F G J K L M N R P = 2@+2.5%, 2@-2.5% = 1@+5%, 1@-5% = 1@-10% = 2@-5% = 4@-2.5% = 1@-10% x 2@-5% = 2@-5% x 4@-2.5% = 2@+2.5%, 4@-2.5% = None = 1@+5%, 2@-5% = 1@+5%, 2@-5% x 2@+2.5%, 4@-2.5% = 1@+4.2%, 1@-4.2% = 1@+2.5%, 3@-2.5% = 1@+3.5%, 1@-3.5% = 2@+3.1%, 2 @-3.1% Taps T U W X Phase A B F E S T = Buck and Boost = 80°C Rise = 115°C Rise = Electrostatic Shield = Single = Three Secondary Voltage 04 06 08 14 12 10 11 54 19 28 29 25 31 26 22 64 24 20 21 27 38 37 34 51 35 62 47 48 60 61 42 41 46 49 = 12/24 = 16/32 = 24/48 = 110/220 = 120 = 120 x 240 = 120/240 = 127/254 = 190Y/110 = 208Y/120 = 208 = 220 Delta = 220Y/127 = 220∆/110 Midtap = 240∆/120 Midtap = 240Y139 = 240 Delta = 240 x 480 = 240/480 = 277 = 380 Delta = 380Y/220 = 400Y/231 = 416Y/240 = 440Y/254 = 460Y/266 = 480Y/277 = 480 Delta = 600 Delta = 600Y/346 = 2400 = 4160Y/2400 = 4160 = 4800 kVA 81 85 82 83 26 51 76 01 16 02 03 05 06 07 09 10 15 21 25 30 37 45 50 75 99 12 49 67 22 52 33 54 55 60 77 11 14 = .05 = .075 = .10 s= .15 = .25 = .50 = .75 =1 = 1.5 =2 =3 =5 =6 = 7.5 =9 = 10 = 15 = 22.5 = 25 = 30 = 37.5 = 45 = 50 = 75 = 100 = 112.5 = 150 = 167 = 225 = 250 = 300 = 333 = 500 = 600 = 750 = 1000 = 1500 Suffix Options A...Z = CU = SS = ZZ = NV = X = LS_ _ = AF = TR = SR = CE = T = EE = NON = POS = NEG = Model number is not used on newly designed/redesigned transformers. Copper windings. Stainless steel (utilizes 316 stainless steel, does not imply a NEMA 4X rating). Open type core and coil assembly. Totally enclosed non-ventilated DS-3 or DT-3. 50/60 Hz. Low sound design. LS47 indicates low sound equal to 47 dB; LS42 indicates 42 dB. Fungus proof. Certified test report of standard production tests. Certified sound level report. CE marked. Thermal indicator embedded in center coil. Suffix “TT” indicates two thermal indicators of different temperature ratings, are installed. NEMA TP-1 Energy Star Energy Efficient. 0º phase-shift +15º phase-shift -15º phase-shift Note: For the Cutler-Hammer Industrial Control Transformers Catalog Numbering System see Page 9-140. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose & Industrial Control Transformers 9-139 November 2003 Catalog Numbering System Vol. 1, Ref. No. [0439] Catalog Numbering System Note: Contact your local Cutler-Hammer sales office for voltage combinations not shown. Use table for catalog number breakdown only. Do not use to create catalog numbers since all combinations may not be valid. Table 9-168. Motor Drive Isolation Transformers — Example: MD145E89B MD 145 E 89 B Type MD = DT-3 HD = KT-4 ND = KT-13 kVA 075 = 7.5 11 = 11 14 = 14 20 = 20 27 = 27 34 = 34 40 = 40 51 = 51 63 = 63 75 = 75 93 = 93 118 = 118 145 = 145 175 = 175 220 = 220 275 = 275 330 = 330 440 = 440 550 = 550 660 = 660 770 = 770 880 = 880 1000 = 1000 1250 = 1250 1500 = 1500 Taps D = 2@+2.5%, 2@-2.5% E = 1@+5%, 1@-5% Voltage Primary Secondary 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 = = = = = = = = = = = = = = = = = 230∆ 208∆ 240∆ 208∆ 208∆ 208∆ 230∆ 230∆ 230∆ 460∆ 460∆ 460∆ 575∆ 575∆ 575∆ 575∆ 600∆ 208Y/120 208Y/120 480∆ 230Y/133 460Y/266 480∆ 230Y/133 460Y/266 575Y/332 230Y/133 460Y/266 575Y/332 230Y/133 460Y/266 575Y/332 480∆ 480∆ Suffix Options Y = Encapsulated (Type EPT) design ES = Electrostatic Shield CU = Copper Windings F = 115°C Rise B = 80°C Rise X = 50/60 Hz 9 For other tap combinations, contact your local Cutler-Hammer sales office. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9-140 Transformers General Purpose & Industrial Control Transformers November 2003 Catalog Numbering System Vol. 1, Ref. No. [0440] Catalog Numbering System Note: Contact your local Cutler-Hammer sales office for voltage combinations not shown. Use table for catalog number breakdown only. Do not use to create catalog numbers since all combinations may not be valid. Table 9-169. Industrial Control Transformers, CE Marked Control Transformers — Example: CE0250G2FES CE 0250 G 2F ES Type C = Industrial Control Transformer CE= CE Marked Control Transformer 9 VA Rating 0025 = 25 0050 = 50 0075 = 75 0100 = 100 0150 = 150 0200 = 200 0250 = 250 0300 = 300 0350 = 350 0500 = 500 0750 = 750 1000 = 1000 1500 = 1500 2000 = 2000 3000 = 3000 5000 = 5000 Type AP Only: 0003 = 3000 0005 = 5000 0007 = 7500 0010 = 10000 0015 = 15000 Modifications Transformer Design A= MTA C = MTC E = MTE G= MTG K = MTK P = AP Voltage Primary AC = AG = 1B = 2A = 2B = 2C = 2F = 2G = 2U = 2V = 2W = 3A = 3B = 3C = 3D = 4B = 4C = 4D = 4E = 4H = 4W = 5E = 6U = 7G = (Type AP Only) 380 x 415 208/240/277/380/480 120 x 240 240 x 480, 230 x 460, 220 x 440 240 x 480 240 x 480 230/460 230/460 220/380/440/550, 230/400/460/575, 240/416/480/600 208/230/400/460/575 208/230/400/460/575 208/277 115 230/460/575 208/380/416 208/230/460/575 550/575/600 380/400/415 208/230/460/575 380/400/415 550/575/600 200/220/440, 208/230/460, 240/480 240/416/480/600, 230/400/460/575, 220/380/440/550, 208/500 240 x 480 Secondary 24 24 24 120/115/110 24 120 x 240 115 115/230 23/110, 24/115, 25/120 24/115/230 115/230 120 24 115/95 115/95 24 110/115/120 110 x 220 115 22/23/24 22/23/24 23/110, 24/115, 25/120 Type MTE/MTG/MTK FB = Factory mounted 2-pole primary fuse block for rejection type fuses FBN = Factory mounted 2-pole primary fuse block for non-rejection type fuses Q = Secondary fuse clips for 1/4 x 1-1/4 inch fuses XX = No Secondary fuse clips RT = Ring type terminals for connection to fuse block ES = Electrostatic shield FS = Factory mounted finger safe terminal shields Type AP B = Bottom mounted S = Side/wall mounted ES = Electrostatic shield CU = Copper windings Type MTA/MTC FB = Factory mounted 3-pole fuse block (2-pole primary rejection type with 1-pole secondary non-rejection type) ES = Electrostatic shield L = Lead terminations 99/120/130, 95/115/125, 91/110/120, 85/100/110 120/240 Note: For the Cutler-Hammer dry-type Transformers Catalog Numbering System see Page 9-138 and 9-139. For more information visit: www.cutler-hammer.eaton.com CA08101001E Transformers General Purpose & Industrial Control Transformers 9-141 November 2003 Vol. 1, Ref. No. [0441] Modifications to General Purpose Units NOT Registered in VISTA Note: These rules apply only to list prices and not to net priced standard transformers. Prior to applying these pricing rules, verify that the style number you require is not already registered in VISTA with a valid list price. List prices in VISTA take precedence over all manually calculated list prices. List price additions for special transformers are intended to be applied to the “base design” nearest to your application. “Base design” is typically a standard 150°C rise, aluminum wound transformer with the same electrical configuration as the special unit you require, i.e., delta-delta connected, or delta-wye connected. List Price Additions Rule 1. Special Primary/Secondary Voltages If either one or both are non-standard (not listed in the catalog section for that particular transformer type), add 10%. Rule 2. Copper Windings The standard winding material is aluminum. For copper windings, add 35%. Note: For units rated 1000 kVA and above, refer to the Eaton’s Cutler-Hammer business. Rule 3. Temperature Rise For 115°C rise, when 150°C rise is standard, on units rated 750 kVA and below, add 15%. For 80°C rise, when 150°C rise is standard, on units rated 500 kVA and below, add 35%. For 80°C rise, when 115°C rise encapsulated is standard, on units rated 45 kVA and below, add 25%. Price Modifications Rule 7. Special Sound Levels Rule 14. CSA Labeled When sound levels below NEMA standard ST-20 are required, add 5% per decibel below NEMA standard levels. This rule cannot be applied to K Factor nonlinear transformers. Contact your Cutler-Hammer representative for special sound requirements, such as low sound K-factor nonlinear products and requirements for sound levels exceeding 5 dB below NEMA standards. For transformers that are CSA labeled, add 10%. Rule 8. Fungus Proofing Fungus proofing consists of spraying all equipment within the wiring compartment with a fungicidal varnish. Add suffix AF to style number if this treatment is required. List price additions are: For electrostatic shields, which form a ground plane between the high and low voltage windings, add 10%. Rule 5. Stainless Steel For transformers with stainless steel enclosures, add 30%. Rule 6. 50 Hertz The standard frequency is 60 Hertz. For 50 Hertz, add 25%. Thermal indicators are included as standard in Cutler-Hammer Type MD Motor Drive Isolation transformers. Thermal indicators are set to activate at a temperature of 190°C. The Cutler-Hammer standard is to install one indicator in the center coil. To have thermal indicators installed in transformers other than Motor Drive Isolation, add $500.00 List Price/Set. Rule 16. Certified Test Reports Ventilated design $500.00/unit Factory certified test reports are available only when they are requested at the time of order entry. The following Certified Test Reports are available: Rule 9. Non-Standard Taps A. Certified Report of Standard Production Tests: Encapsulated design $250.00/unit Standard high voltage taps are listed in this catalog. When more than the listed taps are required, refer to Division. Additional taps are available in 2.5% steps only, up to a maximum of 6 taps. Rule 10. Double Neutral For three-phase applications where a 200% neutral is required, add 5%. Rule 11. Lighting Tap A lighting tap is available on the secondary (delta only) winding of a threephase unit rated 30 through 300 kVA. Tap is limited to 5% rated kVA. Rule 4. Electrostatic Shields Rule 15. Thermal Indicators For a 120 V single-phase tap, add 15%. Suffix TR $500.00/unit List Price addition B. Certified Report of NEMA Sound Level Tests: Suffix SR $1,500.00/unit List Price addition Add the appropriate Suffix from above to the style number when requesting these Certified Test Reports. Net Price Additions Note: Apply after all list price modifications and discounts are calculated. Rule 1. Special Drawings Rule 12. NEMA TP-1 Energy Efficient When paper print factory drawings are required, add $25.00 net per item. For ventilated transformers that meet the NEMA TP-1 and Energy Star energy efficiency standards, add 40%. When sepia paper reproducible factory drawings are required, add $100.00 net per item. Rule 13. CE Marked When aperture cards are required, add $50.00 net per item. For single-phase encapsulated, or ventilated transformers that comply with European standards and have a CE Mark, add 10%. Note: For units rated 1000 kVA and above, refer to the Cutler-Hammer business. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 9-142 Transformers General Purpose & Industrial Control Transformers November 2003 Glossary Vol. 1, Ref. No. [0442] Glossary of Transformer Terms Air Cooled: A transformer which is cooled by the natural circulation of air around, or through, the core and coils Ambient Noise Level: The existing noise level of the area surrounding the transformer, prior to energizing the transformer. Ambient Temperature: The temperature of the air surrounding the transformer into which the heat of the transformer is dissipated. Attenuation: A decrease in signal power or voltage. Unit of measure is dB. 9 Autotransformer: A transformer in which part of the winding is common to both the primary and secondary circuits. Banked: Two or more single-phase transformers wired together to supply a three-phase load. Three single-phase transformers can be “banked” together to support a three-phase load. For example, three 10 kVA single-phase transformers “banked” together will have a 30 kVA three-phase capacity. BIL: Basic Impulse Level. The ability of a transformer’s insulation system to withstand high voltage surges. All Eaton’s Cutler-Hammer 600V-class transformers have a 10 kV BIL rating. Buck-Boost: The name of a standard, single-phase, two-winding transformer application with the low voltage secondary windings connected as an autotransformer for boosting (increasing) or bucking (decreasing) voltages in small amounts. Applications can either be single phase or three phase. Center Tap: A tap at the mid-point of a winding. The center tap on threephase delta-delta transformers is called a lighting tap. It provides 5% of the transformer’s kVA for singlephase loads. Certified Tests: Actual values taken during production tests and certified as applying to a given unit shipped on a specific order. Certified tests are serial number specific. Common Mode: Electrical noise or voltage fluctuation that occurs between all of the line leads and the common ground, or between ground and line or neutral. Compensated Transformer: A transformer with a turns ratio that provides a higher than nameplate output (secondary) voltage at no load, and nameplate output (secondary) voltage at rated load. It is common for small transformers (2 kVA and less) to be compensated. Conductor Losses: Losses (expressed in watts) in a transformer which are incidental to carrying a load: coil resistance, stray loss due to stray fluxes in the windings, core clamps, etc., as well as circulating currents (if any) in parallel windings. Also called load losses. Core Losses: Losses (expressed in watts) caused by magnetization of the core and its resistance to magnetic flux. Also called no-load losses or excitation losses. Core losses are always present when the transformer is energized. Delta Connection: A standard threephase connection with the ends of each phase winding connected in series to form a closed loop with each phase 120 degrees from the other. Sometimes referred to as 3-wire. Dielectric Tests: Tests which consist of the application of a voltage higher than the rated voltage for a specified time for the purpose of determining the adequacy against breakdowns of insulating materials and spacings under normal conditions. Dry-Type Transformer: A transformer in which the core and coils are not immersed in a liquid. Efficiency: The ratio of the power output from a transformer to the total power input. Typically expressed as a %. Electrostatic Shield: Copper or other conducting sheet placed between primary and secondary windings, and grounded to reduce electrical interference and to provide additional protection from line-to-line or lineto-ground noise. Encapsulated Transformer: A transformer with its coils either dipped or cast in an epoxy resin or other encapsulating substance. Excitation Current: No Load Current. The current that flows in any winding used to excite the transformer when all other windings are open-circuited. It is usually expressed in percent of the rated current of a winding in which it is measured. Also called magnetizing current. FCAN: “Full Capacity Above Normal” taps. Designates the transformer will deliver its rated kVA when connected to a voltage source which is higher than the rated primary voltage. FCBN: “Full Capacity Below Normal” taps. Designates the transformer will deliver its rated kVA when connected to a voltage source which is lower than the rated primary voltage. For more information visit: www.cutler-hammer.eaton.com Frequency: On ac circuits, designates the number of times that polarity alternates from positive to negative and back again per second such as 60 cycles per second. Typically measured in Hertz (Hz). Ground: Connecting one side of a circuit to the earth through low resistance or low impedance paths to help prevent transmitting electrical shock to personnel. Hp: Horsepower. The energy required to raise 33,000 pounds a distance of one foot in one minute. 1 hp is equal to 746 watts. Harmonic: A sinusoidal waveform with a frequency that is an integral multiple of the fundamental frequency (60 Hz). Hi Pot: A standard test on dry-type transformers consisting of extra-high potentials (voltages) connected to the windings. Used to check the integrity of insulation materials and clearances. Impedance: The retarding forces of current in an ac circuit; the current-limiting characteristics of a transformer. Symbol = Z Inductance: In electrical circuits, the opposition to a change in the flow of electrical current. Symbol = L Inducted Potential Test: A standard dielectric test of transformer insulation. Verifies the integrity of insulating materials and electrical clearances. Insulation: Material with a high electrical resistance. Insulation Materials: Those materials used to insulate the transformer’s electrical windings from each other and ground. Isolating Transformer: A transformer where the input (primary) windings are not connected to the output (secondary) windings (i.e., electrically isolated). K Factor: A common industry term for the amount of harmonics produced by a given load. The larger the K Factor, the more harmonics that are present. Also used to define a transformer’s ability to withstand the additional heating generated by harmonic currents. kVA: Kilovolt-ampere. Designates the output that a transformer can deliver for a specified time at a rated secondary voltage and rated frequency without exceeding the specified temperature rise. 1000 VA = 1 kVA CA08101001E Transformers General Purpose & Industrial Control Transformers 9-143 November 2003 Vol. 1, Ref. No. [0443] Load Losses: I2R losses in windings. Also see Conductor Losses Mid-Tap: See Center Tap Noise Level: The relative intensity of sound, measured in decibels (dB). NEMA Standard ST-20 outlines the maximum allowable noise level for dry-type transformers. Non-Ventilated Transformer: A transformer where the core and coil assembly is mounted inside an enclosure with no openings for ventilation. Also referred to as Totally Enclosed NonVentilated (TENV). Glossary Ratio Test: A standard test of transformers to determine the ratio of the input (primary) voltage to the output (secondary) voltage. Reactance: The effect of inductive and capacitive components of a circuit producing other than unity power factor. Regulation: Usually expressed as the percent change in output voltage when the load goes from full load to no load. Scott T Connection: Connection for three-phase transformers. Instead of using three sets of coils for a threephase load, the transformer utilizes only two sets of coils. Total Losses: The sum of the no-load losses and load losses. Transformer Tests: Per NEMA ST-20, routine transformer production tests are performed on each transformer prior to shipment. These tests are: Ratio tests on the rated voltage connection; Polarity and Phase Relation tests on the rated connection; No-load and Excitation current tests at rated voltage on the rated voltage connection and Applied Potential and Induced Potential tests. Special tests include sound level testing. Star Connection: Same as a wye connection. Transverse Mode: Electrical noise or voltage disturbance that occurs between phase and neutral, or from spurious signals across metallic hot line and the neutral conductor. Step-down Transformer: A transformer where the input voltage is higher than the output voltage. Turns Ratio: The ratio of the number of turns in the high voltage winding to that in the low voltage winding. Percent IR (% resistance): Voltage drop due to resistance at rated current in percent of rated voltage. Step-up Transformer: A transformer where the input voltage is less than the output voltage. Typical Test Data: Tests that were performed on similar units that were previously manufactured and tested. Percent IX (% reactance): Voltage drop due to reactance at rated current in percent of rated voltage. Tap: A connection brought out of a winding at some point between its extremities, usually to permit changing the voltage or current ratio. Taps are typically used to compensate for above or below rated input voltage, in order to provide the rated output voltage. See FCAN and FCBN. UL (Underwriter’s Laboratories): An independent safety testing organization. No Load Losses: Losses in a transformer that is excited at rated voltage and frequency but which is not supplying a load. No load losses include core losses, dielectric losses, and conductor losses in the winding due to the exciting current. Also referred to as Excitation Losses. Percent IZ (% impedance): Voltage drop due to impedance at rated current in percent of rated voltage. Phase: Type of ac electrical circuit; usually single-phase 2- or 3-wire, or threephase 3- or 4-wire. Polarity Test: A standard test on transformers to determine instantaneous direction of the voltages in the primary compared to the secondary. Primary Taps: Taps added to the primary (input) winding. See Tap. Primary Voltage: The input circuit voltage. Temperature Class: The maximum temperature that the insulation system of a transformer can continuously withstand. The common insulation classes are 105, 150, 180 (also 185) and 220. Temperature Rise: The increase over ambient temperature of the windings due to energizing and loading the transformer. Universal Taps: A combination of six primary voltage taps consisting of 2@+2-1/2% FCAN and 4@-2-1/2% FCBN. Wye Connection: A standard 3-wire transformer connection with similar ends of single-phase coils connected together. The common point forms the electrical neutral point and may be grounded. Also referred to as 3-phase 4-wire. To obtain the line-to-neutral voltage, divide the line voltage by 3 (1.732). Power Factor: the cosine of the phase angle between a voltage and a current. CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 9-144 Transformers General Purpose & Industrial Control Transformers November 2003 Frequently Asked Questions Vol. 1, Ref. No. [0444] Frequently Asked Questions About Transformers Can 60 Hz transformers be used at other frequencies? Transformers rated for 60 Hz can be applied to circuits with a higher frequency, as long as the nameplate voltages are not exceeded. The higher the frequency that you apply to a 60 Hz transformer, the less voltage regulation you will have. 60 Hz transformers may be used at lower frequencies but only at reduced voltages corresponding to the reduction in frequency.For example, a 480 to 120 volt 60 Hz transformer can carry rated kVA at 50 Hz but ONLY when applied as a 400 to 100 volt transformer (50/60 x 480 = 400). 9 Can single-phase transformers be used on a three-phase source? Yes. Any single-phase transformer can be used on a three-phase source by connecting the primary terminals of the single-phase transformer to any two wires of a three-phase system. It does not matter whether the threephase source is three-phase 3-wire or three-phase 4-wire. The output of the transformer will be single-phase. Can transformers be used to create threephase power from a single-phase system? No. Single-phase transformers alone cannot be used to create the phaseshifts required for a three-phase system. Phase shifting devices (reactors or capacitors) or phase converters in conjunction with transformers are required to change single-phase power to three-phase. What considerations need to be taken into account when operating transformers at high altitudes? At altitudes greater than 3,300 feet (1,000 meters), the density of the air is lesser than at lower elevations. This reduces the ability of the air surrounding a transformer to cool it, so the temperature rise of the transformer is increased. Therefore, when a transformer is being installed at altitudes greater than 3,300 feet above sea level, it is necessary to derate the nameplate kVA by 0.3% for each 330 feet (100 meters) in excess of 3,300 feet. What considerations need to be taken into account when operating transformers where the ambient temperature is high? Eaton’s Cutler-Hammer dry-type transformers are designed in accordance with ANSI standards to operate in areas where the average maximum ambient temperature is 40°C. For operation in ambient temperatures above 40°C, there are two options: 1. Order a custom designed transformer made for the specific application. 2. Derate the nameplate kVA of a standard transformer by 8% for each 10°C of ambient above 40°C. What is the normal life expectancy of a transformer? When a transformer is operated under ANSI/IEEE basic loading conditions (ANSI C57.96), the normal life expectancy of a transformer is 20 years. The ANSI/IEEE basic loading conditions are: A. The transformer is continuously loaded at rated kVA and rated voltages. B. The average temperature of the ambient air during any 24-hour period is equal to 30°C and at no time exceeds 40°C C. The altitude where the transformer is installed does not exceed 3,300 feet (1,000 meters). What are Insulation Classes? Insulation classes were originally used to distinguish insulating materials operating at different temperatures. In the past, letters were used for the different designations. Recently, insulation system temperatures (°C) have replaced the letters’ designations. Table 9-170. Insulation Classes Previous Designation Insulation System Rating (°C) Class A Class B Class F 105 150 180 Class H Class R 220 220 For more information visit: www.cutler-hammer.eaton.com How do you know if the enclosure temperature is too hot? UL and CSA standards strictly regulate the highest temperature that an enclosure can reach. For ventilated transformers, the temperature of the enclosure should not increase by more than 50°C in a 40°C ambient at full rated current. For encapsulated transformers, the temperature of the enclosure should not increase by more than 65°C in a 25°C ambient at full rated current. This means that it is permissible for the temperature of the enclosure to reach 90°C (194°F). Although this temperature is very warm to the touch, it is within the allowed standards. A thermometer should be used to measure enclosure temperatures, not your hand. Can transformers be reverse-connected (reverse-fed)? Yes, with limitations. Cutler-Hammer single-phase transformers rated 3 kVA and larger can be reverse-connected without any loss of kVA capacity or any adverse effects. Transformers rated 2 kVA and below, because there is a turns ratio compensation on the low voltage winding that adjusts voltage between no load and full load conditions, should not be reverse-fed. Three-phase transformers with either delta-delta or delta-wye configurations can also be reverse-connected for step-up operation. When reversefeeding a delta-wye connected transformer, there are two important considerations to take into account: (1) The neutral is not connected, only the three-phase wires of the wye system are connected, (2) the ground strap between X0 and the enclosure must be removed. Due to high inrush currents that may be created in these applications, it is recommended that you do not reverse-feed transformers rated more than 75 kVA. The preferred solution is to purchase a Cutler-Hammer step up transformer designed specifically for your application. CA08101001E Transformers General Purpose & Industrial Control Transformers 9-145 November 2003 Frequently Asked Questions Vol. 1, Ref. No. [0445] Can transformers be connected in parallel? Yes, with certain restrictions. For single-phase transformers being connected in parallel, the voltages and impedances of the transformers must be equal (impedances must be within 7.5% of each other). For three-phase transformers, the same restrictions apply as for single-phase transformers, plus the phase shift of the transformers must be the same. For example, a delta-wye-connected transformer (30° phase shift) must be connected in parallel with another delta-wye-connected transformer, not a delta-delta connected transformer (0° phase shift). Why is the impedance of a transformer important? The impedance of a transformer is important because it is used to determine the interrupting rating and trip rating of the circuit protection devices on the load or line side of the transformer. To calculate the maximum short circuit current on the load side of a transformer, use the following formula: Load Current (Amps) Maximum Short Circuit = Full ------------------------------------------------------------------Transformer Impedence Load Current (Amps) Full load current for single-phase circuits is: Nameplate Volt-Amps ----------------------------------------------------------Load (output) Voltage and for three-phase circuits the full load current is: Nameplate Volt-Amps -------------------------------------------------------------------Load (output) Volts × 3 Example: For a standard three-phase, 75 kVA transformer, rated 480 volt delta primary and 208Y/120 volt secondary (catalog number V48M28T75J) and impedance equal to 5.1%, the full load current is: 75,000 VA --------------------------------= 208.2 A The circuit breaker or fuse on the secondary side of this transformer would have to have a minimum interrupting capacity of 4,083 amperes at 208 volts. NEMA ST-20 (1992). A similar transformer with lower impedance would require a primary circuit breaker or fuse with a higher interrupting capacity. What clearances are required around transformers when they are installed? All dry-type transformers depend upon the circulation of air for cooling, therefore it is important that the flow of air around a transformer not be impeded. UL 1561 requires that there be no less than 6 inches (152.4 mm) clearance between any side of a transformer with ventilation openings and any wall or obstruction. In compliance with NEC 450-9, Eaton’s Cutler-Hammer ventilated transformers have a note on their nameplates requiring a minimum of 6 inches (152.4 mm) clearance from the ventilation openings and walls or other obstructions. This clearance only addresses the ventilation needs of the transformer. There may be additional local codes and standards that affect installation clearances. Transformers should not be mounted in such a manner that one unit will contribute to the additional heating of another unit, beyond allowable temperature limits…for example where two units are mounted on a wall one above the other. NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. UL is a federally registered trademark of Underwriters Laboratories Inc. Uniform Building Code (UBC) is a trademark of the International Conference of Building Officials (ICBO). CSA is a registered trademark of the Canadian Standards Association. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, Mass. 208V x 1.732 The maximum short circuit load current is: 208.2 A ------------------- = 4,082.4 A .051 CA08101001E For more information visit: www.cutler-hammer.eaton.com 9 9-146 Transformers November 2003 Vol. 1, Ref. No. [0446] This page intentionally left blank. 9 For more information visit: www.cutler-hammer.eaton.com CA08101001E
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2003:11:26 17:05:31-04:00 Modify Date : 2003:11:26 17:05:31-04:00 Page Count : 146 Creation Date : 2003:11:26 21:05:31Z Mod Date : 2003:11:26 21:05:31Z Producer : Acrobat Distiller 5.0.5 for Macintosh Author : Renee Zmuda Metadata Date : 2003:11:26 21:05:31Z Creator : Renee Zmuda Title : 09_Nov03_final.fmEXIF Metadata provided by EXIF.tools