Table of Contents

IEC Style Disconnect Switches
GS1 Fusible and LK3 Nonfusible, UL98 Tested
GS1 Fusible and LK3 Nonfusible, Dimensions

17-2
17-5

UL508 Motor Disconnect Switches
Mini-Vario and Vario™ Switches

17-8

NEMA Style Disconnect Switches
NEMA Style Door-Mounted Disconnect Switches

17-9

Door-Mounted Operating Mechanisms
Electromechanical
Reduced Voltage Starter (p. 17-18)

For Square D™ Circuit Breakers
Approximate Dimensions

17-10
17-12

Bracket-Mounted Disconnect Devices
Type T Disconnect Switches

17-13

Flexible Cable Mechanisms
For Circuit Breakers

17-14

Disconnect Switch Accessories
Flange Mounted, Variable Depth

17-15

Reversing Drum Switches
Type A and B

17-17

Electromechanical Reduced Voltage Starters
Description of All Types
How to Order
Autotransformer Starters
Wye-Delta Starters (Open Transition)
Wye-Delta Starters (Closed Transition)
Part Winding Starters
Approximate Dimensions

17-18
17-18
17-19
17-20
17-21
17-22
17-23

Multispeed Magnetic Starters
Application Data
Two-Speed Combination Starters
Reversing Two-Speed Magnetic Starters
Two-Speed Magnetic Starters
Approximate Dimensions

17-24
17-26
17-27
17-28
17-29

Lighting Contactors
Panelboard Lighting Contactors, Type PB

17-30

Well-Guard™ Pump Panel
Reduced Voltage Type

17-31

Factory Modifications (Forms)
Reduced Voltage Starters

17-32

Definite Purpose Contactors
Reversing/Hoist, Type R

17-35

Thermal Overload Relays—NEMA Style
Solid-State Overload Relay, Motor Logic™ Plus

© 2012 Schneider Electric
All Rights Reserved

17-36

17-1

17

NEMA Contactors and Starters

NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Section 17

IEC Style Disconnect
Switches

GS1 Fusible and LK3 Nonfusible, UL98 Tested
Class 9421 / Refer to Catalog 9421CT0301

17

The GS1 part numbers can be identified as follows.
See Catalog 9421CT0301 for specific applications.

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Table 17.1:

www.schneider-electric.us

Identification System
GS1

D

U

3

Model GS1 Fusible (Class J fuse unless noted), LK3 Nonfusible
Current Range, Operator Type (front operator unless noted), Accessory Type
D
30 A front and side operation
T
800 A (Class L if fused)
DD
30 A Class CC front and side operation
U
1000 A
E
30 A
W
1200 A
EE
30 A Class CC
AH
handle
G
60 A
AHT
handle with test
J
100 A
AE
extension shaft
M
200 A
AD
auxiliary contact holder
Q
400 A
AM
auxiliary contact
S
600 A
UL Certification
Poles—Number of Poles, 2 or 3
Note: All fusible switches through 400 A and nonfused switches through 200 A are equipped with a feature to test optional auxiliary contacts without energizing
the load when the appropriate GS1AHT•••• handle is used.

Table 17.2:
Catalog No.

200 A Switch
GS1MU3

Table 17.4:
$ Price

Compact GS1 Fusible IEC Style Disconnect Switches
GS1DDU3
30 A, 3-pole, Class CC, use 5x5 shaft
GS1DU3
30 A, 3-pole, Class J, use 5x5 shaft
GS1 Fusible IEC Style Disconnect Switches
GS1EEU3
30 A, 3-pole, Class CC , use 10x10 shaft
GS1EU3
30 A, 3-pole, Class J, use 10x10 shaft
GS1GU3
60 A, 3-pole, Class J, use 10x10 shaft
GS1JU3ab
100 A, 3-pole, Class J, use 10x10 shaft
GS1MU3ab
200 A, 3-pole, Class J, use 10x10 shaft
GS1QU3ab
400 A, 3-pole, Class J, use 10x10 shaft
GS1SU3ab
600 A, 3-pole, Class J, use 15x15 shaft
GS1TU3ab
800 A, 3-pole, Class L, use 15x15 shaft

Table 17.3:
Catalog No.

30 A Side Handle
GS1EERU30

Fusible Switches
Description

237.00
260.00
237.00
260.00
336.00
536.00
1181.00
2252.00
3377.00
5061.00

Description

$ Price

30 A, 2-pole, Class CC

204.00

GS1EERU30

30 A, 3-pole, Class CC

242.00

GS1AH01

Right side handle for GS1EERU20 & GS1EERU30

b

Nonfusible Switches
Description

$ Price

Compact LK3 Nonfusible IEC Style Disconnect Switches
LK3DU3
30 A, 3-pole, 5x5 shaft
LK3 Nonfusible IEC Style Disconnect Switches
LK3GU3
60 A, 3-pole, use 10x10 shaft
LK3JU3
100 A, 3-pole, use 10x10 shaft
LK3MU3ab
200 A, 3-pole, use 10x10 shaft
LK3QU3ab
400 A, 3-pole, use 15x15 shaft
LK3SU3ab
600 A, 3-pole, use 15x15 shaft
LK3TU3ab
800 A, 3-pole, use 15x15 shaft
LK3UU3ab
1000 A, 3-pole, use 15x15 shaft
LK3WU3ab
1200 A, 3-pole, use 15x15 shaft

218.00
263.00
458.00
1010.00
1910.00
2873.00
4301.00
5372.00
6450.00

Fusible Switches with
Direct Mount Side Handle

GS1EERU20

a

Catalog No.

46.40

Shipped with line side terminal shrouds; for additional shrouds,
see page 17-4.
Terminal lug must be ordered separately—see page 17-4.

Compact 30 A Switch
LK3DU3

Example of the parts to order to build a complete GS or LK switch:
Choose a Switch

600 A, LK3SU3

+

Shaft

+

Shaft 200 mm, GS1AE6

Handle Assembly

Black Handle, LK3AH150

+

Lugs, if needed

Lugs Kit, GS1AW503

For example:
LK3SU3 (600 A nonfusible switch, use 15x15 shaft) + GS1AE6 (15x15 200 mm Type H shaft) + LK3AH150 (black/black, lockable)
To add auxiliary contacts:
For front-mounted contacts order GS1AD30 (front-mounted auxiliary contact holder) + GS1AM110 (NO contact for GS1AD10, 20, and 30)

17-2

CP1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

IEC Style Disconnect
Switches

GS1 Fusible and LK3 Nonfusible, UL98 Tested
Class 9421 / Refer to Catalog 9421CT0301

www.schneider-electric.us

Pistol Handles for Compact GS1 and LK3 for Use with Shaft Type D

Type
NEMA/UL

IEC

1, 12

GS1AH101

GS1AH102

Type D—alternate handles
for compact switches only

IP54

Table 17.6:

Yes

Padlockable

Color

Yes

Black
Red/Yellow

IEC

Defeatable

Padlockable

1, 3R, 12

IP54

Yes

Yes

1, 3R, 4, 4X, 12

IP65

Yes

Yes

Compact Shaft Kits

GS1AE7/AE71 Shafts
5 mm x 5 mm

Table 17.7:

Catalog
Number

$ Price

Off/On (O/I)

GS1AH101
GS1AH102

51.00

Color

Operation

Catalog
Number

$ Price

Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow

Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)
Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)

GS1AH110
GS1AH120
GS1AHT110
GS1AHT120
GS1AH410
GS1AH420
GS1AHT410
GS1AHT420

62.00
62.00
117.00
117.00
46.60
46.60
78.00
78.00

Pistol Handles for Standard GS1 and LK3

Type
NEMA/UL

Operation

Pistol Handles for Compact GS1 and LK3 for Use with Shaft Type G

Type
NEMA/UL

Defeatable

IEC

Defeatable

Padlockable

Color

Operation

Catalog
Number

$ Price

Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow

Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)
Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)

GS1AH110
GS1AH120
GS1AHT110
GS1AHT120
GS1AH410
GS1AH420
GS1AHT410
GS1AHT420

62.00
62.00
117.00
117.00
70.00
70.00
117.00
117.00

Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow

Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)
Off/On (O/I)
Off/On (O/I)

GS1AH130
GS1AH140
GS1AHT130
GS1AHT140
GS1AH430
GS1AH440

70.00
70.00
125.00
125.00
78.00
78.00

$ Price

GS1 30–100 A and LK3 60–100 A (3 in. handles)

1, 3R, 12

IP54

Yes

Yes

1, 3R, 4, 4X, 12

IP65

Yes

Yes

GS1 200–400 A and LK3 200 A (5 in. handles)

GS1AH110

GS1AH120

Type G—Standard Handle Design

1, 3R, 12

IP54

Yes

Yes

1, 3R, 4, 4X, 12

IP65

Yes

Yes

Use these shaft kits when
using compact switches:

Table 17.8:

Pistol Handles for Use with Shaft Type H

Type
NEMA/UL

IEC

Defeatable

Padlockable

Color

Operation

Catalog
Number

No
No
Yes
Yes

Yes

Black
Red/Yellow
Black
Red/Yellow

Off/On (O/I)

LK3AH150
LK3AH160
LK3AH170
LK3AH180

233.00
233.00
386.00
386.00

Off/On (O/I)

LK3AH150
LK3AH160
GS1AH170
GS1AH180

233.00
233.00
386.00
386.00

For LK3 400–1200 A

GS1AE8/AE81 Shafts
5 mm x 5 mm

1, 3R, 4, 4X, 12

IP65

For GS1 600–800 A
No
Black
No
Red/Yellow
Yes
Yes
Black
Yes
Red/Yellow
Note: Now UL approved for indoor or outdoor applications.
1, 3R, 4, 4X, 12

Table 17.9:

IP65

Shafts

Length
in.

LK3AH160

GS1AE2/AE21 Shafts

© 2012 Schneider Electric
All Rights Reserved

GS1AE6

mm

Catalog No.

Shaft 5 mm x 5 mm—For use with Pistol Handles, Type D
12.6
320
GS1AE7
15.7
400
GS1AE71
Shaft 5 mm x 5 mm—For use with Pistol Handles, Type G
12.6
320
GS1AE8
15.7
400
GS1AE81
Shaft 10 mm x 10 mm—For Standard GS1 and LK3
12.6
320
GS1AE2
15.7
400
GS1AE21

$ Price

18.60
23.30
18.60
23.30
20.30
24.90

Shaft 15 mm x 15 mm—For use with Pistol Handles, Type H
7.9
200
GS1AE6
32.60
15.7
400
GS1AE61
40.40

CP1

Discount
Schedule

17-3

17

Table 17.5:

NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Handles

IEC Style Disconnect
Switches

GS1 Fusible and LK3 Nonfusible, UL98 Tested
Class 9421 / Refer to Catalog 9421CT0301

www.schneider-electric.us

17

Accessories
Table 17.10:

Auxiliary Contacts

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Type

GS1AD20 +
GS1AM110

GS1AD10 +
GS1AM110

Description

For Compact LK3 / GS1
U = Upper or
Standard products allow up to 4 auxiliary contacts without any extra
Top mounted
contact holders. Contact holder (for 5 to 8 auxiliary contacts)
10 A
1 N.O. Contact Block
600 Vac
1 N.C. Contact Block
For LK3 60–200 A, GS1 30–400 A
U = Upper or
Contact holder required (for 1 to 8 upper auxiliary contacts)
Top mounted
10 A
1 N.O. Contact Block
600 Vac
1 N.C. Contact Block
1 N.O. & N.C. Contact Block (max of two blocks—any mix)
S = Side mounted a
2 N.O. & N.C. Contact Block (max of two blocks—any mix)
1 N.O. & N.C. Contact Block w/ Test (max of two blocks—any mix)
S = Side mounted a
2 N.O. & N.C. Contact Block w/ Test (max of two blocks—any mix)
For LK3 400–1200 A
U = Upper or
Contact holder (for 1 to 4 auxiliary contacts)
Top mounted
10 A
1 N.O. Contact Block
600 Vac
1 N.C. Contact Block

Catalog No.

$ Price

GS1AD10

46.70

GS1AM110
GS1AM101

14.70
14.70

GS1AD20

46.70

GS1AM110
GS1AM101
GS1AN11
GS1AN22
GS1ANT11
GS1ANT22

14.70
14.70
78.00
140.00
93.00
156.00

LK3AD30

46.70

GS1AM110
GS1AM101

14.70
14.70

For GS1 600–800 A
1 N.O./N.C. Contact
GS1AMU3
57.00
Micro-switch
(top mounted)
2 N.O./N.C. Contact
GS1AMU4
83.00
a
Cannot be mixed. A single switch must use all GS1AN11/GS1AN22 contact blocks or all GS1ANT11/GS1ANT22
contact blocks. A GS1AN• • contact block may not be used on the same switch as a GS1ANT• •.

GS1AD30 +
GS1AM110

Table 17.11:

Terminal Lugs

For Use On

Wire Size

Compact GS1/LK3
GS1 30 A CC
GS1 30 A J
GS1/LK3 60 A J
LK3 100 A
GS1 100 A
GS1/LK3 200 A
GS1/LK3 400–600 A b
GS1/LK3 800 A / LK3 1000 A b
LK3 1250 A b
b

Cu
Cu
Cu
Cu
Cu
Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al

Lugs
per Kit
—
—
—
—
—
6
6
6
6
12

Catalog No.

$ Price

Standard
Standard
Standard
Standard
Standard
GS1AW303
GS1AW403
GS1AW503
GS1AW803
GS1AW903

—
—
—
—
—
59.00
98.00
197.00
246.00
395.00

Terminal Shrouds

For Use On

Terminal Shrouds

Wire Type

GS1 600–800 A and LK3 800–1250 A can receive 1 lug for 3 cables per terminal or 2 lugs for 2 cables per terminal.

Table 17.12:

Terminal Lugs

#14–#10
#14–#10
#14–#10
#10–#3
#14–#2/0
#14–2/0
#6–3/0
2 x 2–2 x 600
3 x 2–3 x 600
4 x 2–4 x 600

# of Wires
per Lug
1
1
1
1
1
1
1
2
3
2

Catalog No.

$ Price

For Line or Load Side c
Compact GS1/LK3
Standard
—
All GS1/LK3 30 A
Standard
—
All GS1/LK3 60 A
Standard
—
LK3 100 A
Standard
—
GS1 100 A d
GS1AP33
101.00
GS1/LK3 200 A d
GS1AP43
132.00
GS1 400 A
GS1AP63
213.00
LK3 400–600 A
LK3AP63
86.00
GS1 600–800 A
GS1AP83
140.00
LK3 800–1250 A
LK3AP83
101.00
c
All GS1 and LK3 switches supplied with line side shrouding.
d
Three-piece kit for either line or load side.

Table 17.13:
For Use On

Shorting Links
Shorting Links
per Kit

Catalog No.

$ Price

3

GS1AU203
GS1AU303
GS1AU403
GS1AU503
GS1AU803

29.60
41.90
62.10
93.00
156.00

GS1 60 A
GS1 100 A
GS1 200 A
GS1 400 A
GS1 600–800 A

Table 17.14:

Shaft Padlocking Kit

For Use On
Compact GS1/LK3
LK3 60–200 A
GS1 30–400 A
LK3 400–1250 A

Catalog No.

Standard

$ Price

—

Shorting Links

17-4

CP1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

IEC Style Disconnect
Switches

GS1 Fusible and LK3 Nonfusible, Dimensions
Class 9421 / Refer to Catalog 9421CT0301

www.schneider-electric.us

1.83

Door Drilling

3.75

0.125

96.5

2 ø 4.5
0.59

1.47

2.5
65

1

63

25.6

2.48

ø 31

-OFF

90°

-ON
45

1.78

79.5

FIX 3.125

116

4.56

1.25
2

15

37.3

50

GS1DDU3
Compact CC
30 A

2.75

2.0
0.13

70

Test Position

50

4 ø 4.5

3.0

ø M165

FIX

76.2

3

18.3

0.72

50

17

2.0

65°

o -OFF

3.25

1.25

83.8

ø 31

90°
-ON

GS1AH/AHT110, 120, 410, or 420

1.83

4.13

Door Drilling

46.5

105.5

1.47

2.5
65

0.059

37.3

15

0.13

2 ø 4.5

1.25

3.38
84

4.56
116

28

1.0

2.0

OFF

63

2.48

ø 31

50

GS1DU3
Compact J
30 A

90°

GS1AH110 or 120
-ON

2.75

2.0

0.13

70

2 ø 4.5

FIX

Test Position

50

o -OFF

50

3.88

2.0

0.63
15.8

65°

FIX ø 0.19

3.0

7.62

99

90°

1.25
ø 31

-ON

GS1AH/AHT110, 120, 410, or 420

GS1EEU3,
GS1
CC
30 A

5.69

2.75

144

1.13

70

Fix

29

Door Drilling

0.13
4 Ø 4.5

2.00
50

5.88

133

2.00

149

© 2012 Schneider Electric
All Rights Reserved

0-OFF

50

2.63

3.00

67

76.2

Ø 31

3.88

62

99

CP1

Discount
Schedule

90°

1.25

2.44

Test Position

65°

Fix 5.25

-ON

Dimensions:

NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Dimensions

in.
mm

17-5

IEC Style Disconnect
Switches

GS1 Fusible and LK3 Nonfusible, Dimensions
Class 9421 / Refer to Catalog 9421CT0301

17
NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

GS1EU3/GS1GU3,
GS1
30 A/60 A J

5.63

2.75

143

70

1.50

3.50

38

Door Drilling

89

.13

2.00

4 Ø 4.5
Fix 5.25
133

5.88

50

Test Position
65°

2.00

149

3.00

67

90°

1.25

76.2

Mounting Hole
Dimension:
0.19 in. (4.8 mm)

0-OFF

50

2.63

www.schneider-electric.us

Ø 31

-ON

2.75
70

6.75
171

GS1JU3,
GS1
100 A J

2.75

5.63

70

2.06

143

87

0.13

Fix 6.56
167

183

.25

2.00

4 Ø 4.5

7.19

Terminal Lugs 2/0 Max.

Door Drilling

3.44

52

50

2.00

3.00

84

Ø 31

16

.88

90°

1.25

76.2

Mounting Hole
Dimension:
0.19 in. (4.8 mm)

.63

0-OFF

50

3.31

Ø6.9

Test Position
65°

22

.75
19

-ON

3.31
8.25

84

210

GS1MU3,
GS1
200 A J

6.00

2.75

Fix 2.44
62

152

70

3.44

Door Drilling

87

.13

Fix 7.50
191

8.13

Terminal Lugs 3/0 Max.

.44

2.00
50

4 Ø 4.5

2.00

207

3.75

127

95

1.00
25

0-OFF

50

5.00

11 Ø1 1.6

Test Position
65°

1.50

90°

1.25
Ø 31

Mounting Hole
Dimension:
0.19 in. (4.8 mm)

38

-ON

1.13
29

3.69
94

9.44
240

GS1QU3,
GS1
400 A J

2.81

Fix 2.81
72

5.56

2.75

72

141

3.44

70

50

4 Ø 4.5

Fix 8.81
224

0-OFF

50

4.44

5.00

112

Ø 31

303

GS1SU3/GS1TU3,
GS1
600 A J
and 800 A L

1.50

3.13

90°

1.25

127

10
Ø 10.2

Test Position
65°

2.00

363

11.94

.38

2.00

0.13
14.31

Terminal Lugs
2 x 600 MCM Max.

Door Drilling

87

38

80

Mounting Hole
Dimension:
0.25 in. (6.3 mm)

-ON

Ø .25
6
2.06

2.88
73

52

Door Drilling

Ø 9.38
2.50
64

Fix 13.63
346
Fix 9.88
251

2.00
3.13

1.50
38

80

7.13
181

19.38
492

4.13
.25 106
7

Locking
55˚

9.88
250 6.00

14.25

2.00
51

51

152

7.50

362

Ø 1.25
31

0.13

Ø 4.5
Terminal Lugs
2X600 MCM Max. 3X600 MCM Max.
Ø 44
Ø .38
2.75
11
10
69

190

2.50
64

3.88
2.38
59

4.75 4.75
120 120

98

4.00

7.50
.50
13

100

20.38
517

190

3.13
80

1.50 3.56
38

1.56

2.88

3.00

91

73

Mounting Hole
Dimension:
0.38 in. (9.6 mm)

40

76

Dimensions:

17-6

CP1

Discount
Schedule

in.
mm

© 2012 Schneider Electric
All Rights Reserved

IEC Style Disconnect
Switches

GS1 Fusible and LK3 Nonfusible, Dimensions
Class 9421 / Refer to Catalog 9421CT0301

www.schneider-electric.us

2.59

3.78
96

66

0.59
15

1.94
37

1.00
25

0.75
19

1.00
25

Door Drilling

0.13

2.00

2 Ø 4.5

1.83

116
1.78
Fix 3.13 45
80

1.25

3.84

0-OFF

Ø 31

98

0.56
14

90°
-ON

2.48
63

Fix Ø .19
M5

18

2.75
ø 0.19

3.88

70

FIX 1.50

5

99

Door Drilling

3.50

38

89

2.00

.13

50

Test Position

4 Ø 4.5

FIX 5.25

5.88

2.63

90°

1.25

76.2

Mounting Hole
Dimension:
0.19 in. (4.8 mm)

0-OFF

50

3.00

67

65°

2.00

133

149

17

0.72

LK3GU3/LK3JU3,
LK3
60 A/100 A

Mounting Hole
Dimension:
0.19 in. (4.8 mm)

51

46

4.56

Ø 31

-ON

2.75
70

6.69
170

LK3MU3,
LK3
200 A

3.44

2.75

2.44

Ø .19
5

87

70

62

Door Drilling

0.13

Terminal Lugs 3/0 Max.

.44

2.00

4 Ø 4.5

50

Fix 7.50
191

8.13

3.75

127

95

0-OFF

50

5.00

11
Ø11.6

Test Position
65°

2.00

206

1.00

1.50

90°

1.25
Ø 31

25

38

Mounting Hole
Dimension:
0.19 in. (4.8 mm)

1.13

-ON

29

3.69
94

9.50
241

LK3QU3/LK3SU3,
LK3
400 A/600 A

Terminal Lugs
2 x 600 MCM Max.

6.56
166

3.13

1.56

.38

1.63

5.00

Fix 12.63
320

127

Fix 6.88
175

2.31

2.00

20

51

1.50
38

Mounting Hole
Dimension:
0.25 in. (6.3 mm)

.13

4 Ø 4.5

98

0.56
11.00

80

Ø 31

191

14

3.13

1.25
3.88

0.81

2.00

51

7.50

59

10
Ø 10.2

Door Drilling

41

80

40

2.88
73

Fix 10.06
255

279

LK3TU3/LK3UU3/
LK3WU3,
LK3
800 A/1000 A/1250 A

Door Drilling

6.56
6.81
2.50

173

166

4.75

51

Ø 1.25
31

Ø 4.5
Terminal Lugs
2X600 MCM Max. 3X600 MCM Max.
Ø 44
Ø .38
11
10

330

59

Fix 6.88
175

0.81

7.50

20

20

2.00

51

1.56

0.13

13.00

2.31

0.81

2.00
40

121

64

14.63

2.50

3.88

1.56
40

191

64

98

Fix 13.69
347

3.13
80

1.50 3.56
38

1.56

2.88

3.00

91

Mounting Hole
Dimension:
0.38 in. (9.6 mm)

40

372

73

76

Dimensions:

© 2012 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

LK3DU3,
Compact LK3
30 A

in.
mm

17-7

UL508 Motor Disconnect
Switches

Mini-Vario and Vario™ Switches
Refer to Catalog 9421CT0301

www.schneider-electric.us

17

Vario

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

The Vario Motor Disconnect Switch is also offered as an enclosed switch made of corrosion
resistant material. The 3-pole version makes the Vario switch ideal for manual motor control
applications. The switches are compact, easy to wire and connect, and come undrilled to
allow variable cable entry positions.
NOTE: VCGUN enclosures are UL approved.
Table 17.15:

Non-Metallic Enclosed Switches a
Ampere Size
IEC

Catalog No.

$ Price

20

32

VC1GUN

239.00

25

40

VC2GUN

287.00

45

63

VC3GUN

345.00

63

80

VC4GUN

381.00

100

125

VC5GUN

548.00

115
175
VC6GUN
Assembled, includes switches mounted in enclosure with handle.

845.00

Non-Metallic Enclosure

a

Table 17.16:

.25
Ø 6.2

IP55-PVC 3-Pole, NEMA Type 1 & 12

UL

Non-Metallic Enclosed Switch Dimensions a
Dimensions
No.
of
Poles

Catalog No. a

Legend
Plate
Holder

d a

VC1GU–VC6GU

17-8

c

d

e

f

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

6.7

170

4.1

105

3.2

82

4.8

122

2.1

53

5.0

128

6.7

170

5.3

135

3.3

85

5.1

130

3.7

95

5.2

131

VC5GU–VC6GU
11.0
a
UL Rated, NEMA Type 1, 12, IP55.

280

8.6

220

5.0

126

7.9

201

7.5

190

8.6

203

VC1GU–VC2GU

c

b

in.

VC3GU–VC4GU

e
b

a

3

f

Table 17.17:

Vario Manual Motor Control Switches, IEC
kW Rating

3-Pole Switch Body

Rating (A)
IEC

230 V

240 V

400 V

415 V

500 V

20

4

4

5.5

5.5

7.5

11

25

5.5

5.5

7.5

7.5

11

15

690 V

32

5.5

5.5

11

11

11

15

40

7.5

7.5

15

15

18.5

15
22

63

15

15

22

22

30

80

18.5

18.5

30

30

37

30

125

22

22

37

37

45

37

175

30

30

45

45

55

45

CP1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

NEMA Style Disconnect
Switches

NEMA Style Door-Mounted Disconnect Switches
Refer to Catalog 9420CT9701

www.schneider-electric.us

Table 17.18:

Disconnect Switches
(without fuse clips or shorting straps)

Table 17.22:

Max. Horsepower Ratinga

Rating
(A)

120 V

0–1
2
3
4

30
60
100
200

5
10
15
25

200–
240 V
10
20
30
50

480 V

600 V

Catalog
Number

20
40
60
100

25
50
75
100

D10S1
D10S2
D10S3
D10S4

$ Price
270.00
292.00
452.00
860.00

a

Rating
(A)

Max. Horsepower Rating a
200–
240 V
10
20
30
50

120 V

0–1
30
5
2
60
10
3
100
15
4
200
25
a
Nonfused ratings.

Line Shield

Table 17.19:

Rating
(A)

480 V

600 V

Catalog
Number

20
40
60
100

25
50
75
100

D10S1H
D10S2H
D10S3H
D10S4H

B F

Complete Kit with
Handle, Shaft, and
Actuator

A E
Centerline
of Switch
Operating
Shaft
I
J
D
C

Enclosure Interior
Depth—Inches
5–6
6–10
10–16
6
12

30,
60,
100,
200

Shaft only

Table 17.20:

$ Price
320.00
352.00
544.00
1154.00

Catalog
Number
D11SF4
D11SF10
D11SF16
D11SH10
D11SH16

$ Price
106.00
118.00
130.00
26.20
32.80

Auxiliary Electrical Interlock

(for mounting on 30–200 A disconnect switch a)
Block Description
(with switch contacts open)

Catalog
Number
D11N0
D11NC
D11N0C
D11N00
D11N0C2

1 N.O.
1 N.C.
1 N.O. and 1 N.C.
2 N.O.
2 N.O. and 2 N.C.
a
One block per switch.

Table 17.21:

Wire Type

#14–#8
#14–#4
#14–#1/0
#6–250 kcmil

Cu
Cu
Al–Cu
Al–Cu

Fuse Clip Kits

Fuse Clip Rating a
Catalog
Number
Amperes
AC Volts
Type
No Fuse
D12C01
0–30
250
H, K
D12C21
0–30
250
R
D12CR21
0–30
600
H, K
D12C61
0–30
600
R
D12CR61
30 A
0–30
600
J
D12CJ1
31–60
250
H, K
D12C22
31–60
600
H, K
D12C62
31–60
600
R
D12CR62
31–60
600
J
D12CJ2
61–100
250
H, K
D12C23
No Fuse
D12D02
0–30
250
R
D12DR21
0–30
600
H, K
D12D61
0–30
600
R
D12DR61
31–60
250
H, K
D12D22
31–60
250
R
D12DR22
60 A
31–60
600
H, K
D12D62
31–60
600
R
D12DR62
31–60
600
J
D12DJ2
61–100
250
H, K
D12D23
61–100
600
H, K
D12D63
61–100
600
J
D12DJ3
61–100
600
R
D12DR63
No Fuse
D12E03
31–60
250
H, K
D12E22
31–60
600
H, K
D12E62
61–100
250
H, K
D12E23
61–100
250
R
D12ER23
100 A
61–100
600
H, K
D12F63
61–100
600
R
D12FR63
61–100
600
J
D12EJ3
101–200
250
H, K
D12F24
600
H, K
D12F64
101–200
101–200
600
J
D12FJ4
No Fuse
D12F04
61–100
600
H, K
D12F63
101–200
250
H, K
D12F24
200 A
101–200
250
R
D12FR24
101–200
600
H, K
D12F64
101–200
600
R
D12FR64
101–200
600
J
D12FJ4
a
Continuous current should not exceed switch rating (size).
Fuse clip kits should be sized to accommodate inrush.

Rotary Handle Operator Kits and Shafts

Description

Wire Range a

D10
Switch Size

Kits include: Handle, Shaft, and Actuator
NEMA Type 1, 3, 3R, 4, and 12
G
H

30
60
1
100
200
One conductor per lug.

Table 17.23:

600 V—With Service Entrance Rating
Starter
NEMA
Size

Number
Per Pole

Rating (A)

600 V—Without Service Entrance Rating
Starter
NEMA
Size

Lug Data

$ Price
79.00
79.00
116.00
116.00
130.00

Interrupting and Withstandability
Ratings

Rating
(A)

Interrupting Rating
Amperes Symmetrical
600 Vac, 3Ø

Withstandability I2T
(Amperes2 seconds)

30

1,200

0.38 x 106

60

1,800

1.28 x 106

100

2.000

2.62 x 106

200

3,600

5.25 x 106

$ Price
8.30
16.30
65.00
24.50
65.00
49.30
24.50
49.30
82.50
57.50
65.00
24.50
65.00
24.50
65.00
23.80
82.50
41.00
82.50
57.50
65.00
115.00
106.30
113.80
49.30
41.00
41.00
32.50
115.00
90.00
115.00
115.00
106.30
122.50
140.00
82.50
90.00
106.30
140.00
122.50
135.00
140.00

Note: These switches are for motor circuit applications.

Table 17.24:

Width

Mounting Hole Dimensions

Depth

A

B

C

D

E

F

G

H

I

J

Ka

lb

30

7-5/16

4-15/32

5-7/8

3-15/32

6

3-15/32

1-7/8

13/32

5-7/16

3-1/4

4-3/32

4-11/32

60

7-5/16

4-15/32

5-7/8

3-15/32

6

3-15/32

1-7/8

13/32

5-7/16

3-1/4

4-11/32

4-11/32

100

9-27/32

5-11/32

8-3/16

4-5/8

5-13/16

3-13/16

2-11/16

51/64

7-5/16

4-3/16

5-23/32

4-27/32

12-3/16

7-7/32

8-3/16

4-5/8

5-13/16

3-13/16

2-11/16

51/64

7-5/16

4-3/16

5-23/32

4-27/32

200
a
b

© 2012 Schneider Electric
All Rights Reserved

Switch Dimensions (in inches)
Length

Rating
(A)

Maximum depth with largest fuse.
Depth including insulating barrier on service entrance switches.

CP1

Discount
Schedule

17-9

17

The D10 disconnect switch features high I2T rating, longer contact life, visible contact indication, fuse-mounting flexibility, dead-front construction,
and auxiliary interlocks.
A complete installation includes a D10 disconnect switch, D11 handle operator, and D12 fuse clip kit. The D10 accepts Class H, K, J, or R fuses, or
can be used for nonfusible applications. The D10 disconnect switch is operated by a cast metal handle operator that is lockable in the “Off” position
and defeatable in the “On” position.

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

File D10

Door-Mounted Operating
Mechanisms

For Square D™ Circuit Breakers
Class 9421 / Refer to Catalog 9420CT9701

www.schneider-electric.us

17

Type L Circuit Breaker Mechanisms

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Type L door-mounted, variable-depth operating mechanisms feature heavy duty, all metal construction with trip
indication. All can be padlocked in the “Off” position when the enclosure door is open. Further, the handle assemblies
can be locked “Off” with up to three padlocks, which also locks the enclosure when the door is closed. (The 3” handle
accepts one padlock.) Complete kits are rated for NEMA Type 1, 3R, and 12 enclosures. They include a handle
assembly, operating mechanism, and shaft assembly.

Table 17.25:

Complete Kits

Complete Kit
Does Not Include Circuit Breaker

No.
of
Poles

Frame
Size
(A)

Includes:
Operating Mechanism
Standard 6 in. Handle
Standard Shaft Kit
Mounting
Type
$ Price
Depth a
Min. – Max.

Use With

Operating
Mechanism

Circuit Breaker or
Interrupter Type
GJL

Includes:
Operating Mechanism
Short 3 in. Handle
Long Shaft Kit
Mounting
Type
$ Price Depth a
Min. – Max.

3

75, 100

LG1

140.00

5-1/2–10-1/4

LG4

158.00

5-1/2–20-7/8

LG3

FAL, FCL, FHL

2–3

100

LN1

140.00

5-1/2–10-7/16

LN4

158.00

5-1/2–21

LN3

198.00

KAL, KCL, KHL

2–3

250

LP1

171.00

6-1/4–11-3/16

LP4

189.00

6-1/4–21-3/4

LP3

230.00 6-1/4–21-3/4

LJ3

230.00 5-1/2–21-3/8

LALc, LHLc, Q4L

2–3

400

LR1

242.00

6-5/16–10-7/8

LR4

255.00

6-5/16–21-1/2

MEL, MXL

2–3

800

LT1b

242.00

7-3/16–11-5/8

LT4b

255.00

7-3/16–22-1/4

MAL, MHL

2–3

1200

LT1b

242.00

7-3/16–11-5/8

LT4b

255.00

7-3/16–22-1/4

NAL, NCL, NEL, NXL

2–3

1200

LX1b

242.00

8-1/4–12-3/4

LX4b

255.00

8-1/4–23-3/8

Table 17.26:

198.00 5-1/2–20-7/8
5-1/2–21

3 in. handles are not recommended
for use with these circuit breakers.

Component Parts

Circuit Breaker or
Interrupter Type
GJL

Standard
Handle
Assemblies
Type 1, 3R, 12

3 in. Handle
Assemblies
Type 1, 3R, 12

Use With
No.
of
Poles

Frame
Size
(A)

Type

$ Price Type

Operating
Mechanism
(Lockout
Included)

$ Price Type

$ Price

Standard Shaft
(Support Bracket
Not Required)
Mounting
Depth a
Min. – Max.

Long Shaft
(Support Bracket
Included)

Type

$ Price

Mounting
Depth a
Min. – Max.

Type

$ Price

3

75, 100

LH3

90.00

LH6

50.00

LG7

68.00 5-1/2–10-7/16

LS8

21.50

5-1/2–21

LS13

35.60

FAL, FCL, FHL

2–3

100

LH3

90.00

LH6

50.00

LF1

71.00 5-1/2–10-7/16

LS8

21.50

5-1/2–21

LS12

35.60

KAL, KCL, KHL

2–3

250

LH3

90.00

LH6

50.00

LK1

105.00 6-1/4–11-3/16

LS8

21.50

6-1/4–21-3/4

LS12

35.60

3 in. handles
LH6
50.00 LL1
170.00 6-5/16–10-7/8 LS8
21.50 6-5/16–21-1/2
are not
MEL, MXL
2–3
800
50.00 LM1
170.00 7-3/16–11-5/8 LS8
21.50 7-3/16–22-1/4
recommended LH8
MAL, MHL
2–3
1200 for use with
LH8
50.00 LM1
170.00 7-3/16–11-5/8 LS8
21.50 7-3/16–22-1/4
these circuit
NAL, NCL, NEL, NXL
2–3
1200 breakers.
LH8
50.00 LX7
170.00 8-1/4–12-3/4 LS8
21.50 8-1/4–23-3/8
a
Mounting depth in inches, measured from circuit breaker mounting surface (control panel) to outside of enclosure door.
b
Types LT1, LT4, LX1, and LX4 include an 8 in. handle rather than a 6 in. handle.
c
These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix.

LS10

35.60

LS10

35.60

LS10

35.60

LS10

35.60

LALc, LHLc, Q4L

Table 17.27:

2–3

400

NEMA Type 4 and 4X Handle Assemblies a
Use With

3 in. Handle
Assembly

Circuit Breaker or
Interrupter Type
GJL

Standard
Handle
Assembly

Includes:
Operating Mechanism
Standard 6 in. Handle
Long Shaft Kit
Mounting
Type
$ Price
Depth a
Min. – Max.

Standard Handle Assemblies
NEMA Type 1, 3R,
4, 12
(Painted)

3 in. Handle Version

NEMA Type 1, 3R,
4, 4X, 12
(Chrome Plated)

NEMA Type 1, 3R,
4, 12
(Painted)

NEMA Type 1, 3R,
4, 4X, 12
(Chrome Plated)

No.
of
Poles

Frame
Size
(A)

Type

$ Price

Type

$ Price

Type

$ Price

Type

$ Price

3

75

LH46

90.00

LC46

149.00

LH43

165.00

LC43

233.00

FAL, FCL, FHL

2–3

100

LH46

90.00

LC46

149.00

LH43

165.00

LC43

233.00

KAL, KCL, KHL

2–3

250

LH46

90.00

LC46

149.00

LH43

165.00

LC43

233.00

LAL, LHL, Q4L

2–3

400

LH46

90.00

LC46

149.00

MEL, MXL

2–3

800

LH48

90.00

LC48

149.00

MAL, MHL

2–3

1000

LH48

90.00

LC48

149.00

NAL, NCL, NEL, NXL
2–3
1200
LH48
90.00
LC48
a
Due to gasketing, NEMA Type 3 and 4 handle assemblies are not trip indicating.

149.00

Table 17.28:

IEC Style Operating Mechanisms

a

Color
Red/Yellow
Black
Contains support bracket.

Table 17.29:

Operating Mechanism
(Lockout Included)

Type 1, 4, 4X, 12

Circuit Breaker or
Interrupter Type
GJL

3 in. handles are not recommended
for use with these circuit breakers.

Type
NW3

$ Price
90.00

NW3B

90.00

Type
LG8

$ Price
71.00

Extension Shafts
Mounting Depth

Type

$ Price

Min.
6-1/8

Max.
10-3/4

NS16

28.70

6-1/8

17-7/8

NS336a

35.60

Electrical Interlock Kits—Class 9999 a

Description
Class
Type
$ Price
Single-Pole, Double-Throw
9999
R47
131.00
Double-Pole, Double-Throw
9999
R48
221.00
a
Optional accessory for use with 9421L operating mechanisms. Not used with GJL, NAL,
NCL, NEL, NXL, NSF, NSJ, PowerPact™ C, D, H, and J circuit breakers; use field-installed
circuit breaker interlocks instead.

17-10

CP1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Approximate
Dimensions

Door-Mounted Operating Mechanisms

3.50 Min.

1.38

Refer to NEC
Article 430-10
for minimum
dimension from
top mounting hole
to wall or barrier
X to ensure adequate
wire bending space.

45

1.18
30
.50
13

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Class 9421 / Refer to Catalog 9420CT9701

www.schneider-electric.us

35

L

4.72 1.77
45
120

CLHandle
Mechanism

3.94
100

Screw Driver
Interlock Pin
Location

.45

7 Door Thickness

CLHandle Mechanism

(2) #8-32 Tap

17

.28 Maximum

12

2.38
60

H
Mounting Depth a

Panel drilling for GJL circuit breaker
and operating mechanism

Table 17.30:

Shaft Cutting Dimensions

Class

a

L = Overall shaft length
H = Distance from inside of enclosure door to circuit
breaker mounting surface

Type

Shaft Length
Formula

H = Standard Shaft

H = Long Shaft

Min.
Max.
L = H–2.50
5.50
10.25
9421
LG7, LG1, LG4, LG3
64
140
260
L = H–2.88
5.50
10.44
9421
LF1, LN1, LN3, LN4
73
140
265
L = H–3.63
6.25
11.19
9421
LK1, LP1, LP3, LP4
92
159
284
L= H–3.13
6.31
10.88
9421
LL1, LR1, LR4
79
160
276
L= H–4.00
7.18
11.63
9421
LM1, LT1, LT4
102
182
295
L= H–5.17
8.25
12.75
9421
LX7, LX1, LX4
131
210
324
Mounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door.

3.25 Minimum
83

(Both Sides)

7.00

4.50

2.25

114

Hinge
Point of
Door

1.50
38

57

.75
19

1.63 R
41

1.56
40

178
Minimum to wall or
barrier to ensure
adequate wire bending
space to lug surface
when maximum wire
size is used with
standard lugs.
Refer to NEC Article
430-10.
CL Handle
Mechanism

Min.
5.50
140
5.50
140
6.25
159
6.31
160
7.18
182
8.25
210

Max.
20.85
530
21.00
533
21.75
552
21.50
546
22.25
565
23.38
594

3.25 Minimum
83

13.50

(Both Sides)

4.50

2.25

114

Hinge
Point of
Door

1.50
38

57

.75
19

1.81
46

343
Minimum to wall or
barrier to ensure
adequate wire bending
space to lug surface
when maximum wire
size is used with
standard lugs.
Refer to NEC Article
430-10.

5.13
7.13

6.00
152

181

CL Handle & Ckt. Bkr. T oggle

(4) #8-32 Tap

CL Handle & Ckt. Bkr. T oggle

130

1.63 R
41

6.00
152

(4) #10-24 Tap

C30080-120

Panel drilling for FAL, FCL, and FHL
circuit breakers and operating mechanisms

Panel drilling for KAL, KCL, and KHL
circuit breakers and operating mechanisms

Dimensions:
© 2012 Schneider Electric
All Rights Reserved

in.
mm

17-11

Approximate
Dimensions

Door-Mounted Operating Mechanisms
Class 9421 / Refer to Catalog 9420CT9701

17
NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

6.00 Minimum
152 (Both Sides)
Hinge
6.00
Point
3.00 152
of Door
76

487

2.00
2.00 51

.88
22

Minimum to wall or barrier
to ensure adequate wire
bending space to lug surface
when maximum wire size is
used with standard lugs.
Refer to NEC Article 430-10.

51

1.00

8.00 Minimum
203 (Both Sides)
Hinge
4.50
Point
114
of
Door

19.19

25

CL
Circuit Breaker

1.63R

119

CL Handle

(4) #12-24 Tap

76

1.50

3.09
79

(4) 1/4-20 Tap

1.03
26

9.25

4.68

3.00

CL
Circuit Breaker

(4) 1/4-20 Tap

A

14

CL Handle

51

(4) 5/16-18 Tap

.56

41

235

X
Minimum to wall or
barrier to ensure
adequate wire bending
space to lug surface
when maximum wire
size is used. Refer to
NEC Article 430-10.

2.00
38

125

40

229

42

4.937

116

9.00

1.66

1.59

4.57

www.schneider-electric.us

CL
Handle

3.50
89

2.68
68

.38

CL
Handle

B

10

.44

11

203

11

.38
.44

8.00

10

1.63R

6.00

41

152

5.09
.88

10.19

7.19

22

129

259

183

Panel drilling for LAL, LHL, and Q4L
circuit breakers and operating mechanisms

Panel drilling for MAL, MEL, MHL, and MXL
circuit breakers and operating mechanisms

Dimensions = in. (mm)

Circuit Breaker Type

A

B

MAL, MHL

10.69 (272)

14.00 (356)

MEL, MXL

11.47 (291)

14.75 (375)

C

L
9.00 Minimum (Both Sides)
Handle Mechanism
229
15.00
381
Hinge
3.16
7.50
Point
80
191
of Door
5.00
1.66
127
42
(4) 1/4-20 Tap
2.50
64

12.13
308

9.50
241

CL Handle
Mechanism

8.75
222

1.63R
41

8.00
203

CL
Circuit Breaker

8.50
216

Panel drilling for NAL, NCL, NEL, and NXL
circuit breakers and operating mechanisms

Dimensions:

17-12

in.
mm

© 2012 Schneider Electric
All Rights Reserved

Bracket-Mounted
Disconnect Devices

Type T Disconnect Switches

www.schneider-electric.us

Table 17.31: Bracket-Mounted Operating Mechanisms for Use With Square D™ Circuit Breakers
The circuit breaker operating mechanisms listed below are shipped with the external operating handle assembled to a
bracket. Circuit breakers are not included and must be ordered separately. A trim plate is provided with each kit to
prevent any mounting screws from being accessible from the front and also to provide an attractive installation.The
operating handle is Type A1. These switches can be used with Class 9423 door closing mechanisms.
Operating Mechanism
Use With
Circuit Breaker or
Interrupter Type

No. of
Poles

Right Hand
Flange Mounting
Frame Size
(A)

Cat. No.

$ Price

FAL, FHL
2–3
100
BN1
257.00
KAL, KHL
2–3
250
BP1
270.00
LALa, LHLa, Q4L
2–3
400
BR1
543.00
a
These operating mechanisms cannot be used with any LA/LH circuit
breaker with an MB or MT suffix.

Table 17.32: Electrical Interlock Kits—Class 9999
Optional accessory for use with circuit breaker operating
mechanisms listed to the left and the flexible cable
mechanisms listed below, except GJL.
Description
Single Pole, Double Throw
Double Pole, Double Throw

Class

Type

$ Price

9999
9999

R26
R27

131.00
243.00

Note: Not used with GJL; use field installed circuit breaker interlocks.

0.38

17

Note: Some enclosures may not accept the listed bracket-mounted
operating mechanisms; contact the enclosure manufacturer.
F

10

Table 17.33:

Dimensions

C

A
C
D
Min. Enclosure Deptha
F
in. (mm)
in. (mm)
in. (mm)
in. (mm)
in. (mm)
BG1, BN1
8.75 (222)
7.13 (181)
1.13 (29)
6.50 (165)
8.00 (203)
BP1
9.13 (232)
7.38 (187)
a
The minimum enclosure depth is greater than Dimension D since additional space is needed when mounting
the mechanism.
Note: Back panel support is recommended for Types TFB1, 2, and 3. Other devices may also require support if the
flange is not sufficiently rigid.
Type

D
Disconnect
Device

0.38
10

Disconnect
Device

ON

A E
OFF

0.38
10

Non Fused
and Circuit
Breaker

Fused

(2) 0.38

Dia. Mounting Holes
10
(For back panel support if necessary.)

For use with Square D circuit breakers and Class 9422 A handle operators. Especially designed for tall, deep
enclosures where placement flexibility is required. See Digest 176 page 8-24 for dimensions.
Table 17.34:

Class 9422—Flexible Cable Mechanisms for Use With Square D Circuit Breakers

Cable Mechanism
Cable Length
Catalog No.
36 in.
CGJ30
48 in.
CGJ40
GJL
3
100
60 in.
CGJ50
120 in.
CGJ10
36 in.
CFA30
FAL, FHL
2, 3
100
60 in.
CFA50
120 in.
CFA10
36 in.
CKA30
KAL, KHL
2, 3
250
60 in.
CKA50
120 in.
CKA10
36 in.
CLA30
LALa, LHLa, Q4L
2, 3
400
60 in.
CLA50
120 in.
CLA10
a
These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix.
Circuit Breaker
Type

Table 17.35:

No. of
Poles

Frame Size
(A)

$ Price
273.00
291.00
291.00
333.00
273.00
291.00
333.00
288.00
305.00
347.00
486.00
504.00
548.00

Cable Mechanisms with A1 Handle
Catalog No.
$ Price
CGJ31
417.00
CGJ41
432.00
CGJ51
432.00
CGJ11
476.00
CFA31
417.00
CFA51
432.00
CFA11
476.00
CKA31
431.00
CKA51
446.00
CKA11
489.00
CLA31
630.00
CLA51
647.00
CLA11
689.00

Class 9999 Auxiliary Contact Kits for Disconnect Switches and
Circuit Breakers
SPDT

Class

DPDT

Type
Type

$ Price

Type

$ Price

R8

87.00

R9

243.00

Disconnect Switches
9422

TF

Circuit Breaker Operating Mechanisms
9421

LF, LK, LL, LM, LN, LP, LR, LT

R47

131.00

R48

221.00

9422

RM, RN, RP, RR, RT

R26

131.00

R27

243.00

9422

CFA, CKA, CLA, CSF

R26

131.00

R27

243.00

Note: No external auxiliary contacts are available for the following circuit breakers:
GJL circuit breakers must use internal auxiliary contacts, catalog number AAC.
PowerPact D circuit breakers must use internal auxiliary contacts, catalog number AAC.
Note: For additional variations, contact the Customer Care Center (CCC) at 1-888-778-2733.

© 2012 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Class 9422 / Refer to Catalog 9420CT9701

17-13

Flexible Cable
Mechanisms

For Circuit Breakers
Class 9422 / Refer to Catalog 9420CT9701

www.schneider-electric.us

17

Dual Cable Operating Mechanisms for Square D™ Circuit Breakers

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Dual cable operator mechanisms are designed for use with Square D GJL circuit breakers.
The cable mechanisms allow for a single handle operator, Class 9422A1, to operate both
circuit breakers. The cable mechanism is designed especially for tall, deep enclosures
where placement flexibility is required. There are numerous cable arrangements to choose
from to accommodate many applications.

Features

•
•
•
•
•

Separate cables for each circuit breaker
Rugged metal flange handle operator
Maximized flexibility of circuit breaker placement for existing and new applications
Control panel can be fed from two separate supply voltages (if required)
Dual mechanism allows both separate supply voltages to be controlled by a single
handle to improve security features

Table 17.36:

Dual Cable Operating Mechanisms Selection

Circuit Breaker Type

GJL

Table 17.37:

FAL

CP1

Catalog
Number

Frame Size
(max.)

$ Price

36 in. / 914 mm (2)

9422CGJD3

48 in. / 1219 mm (2)

9422CGJD4

585.00
608.00

60 in. / 1524 mm (2)

9422CGJD5

675.00

120 in. / 3048 mm (2)

9422CGJD1

36 in. / 914 mm (1)
60 in. / 1524 mm (1)

9422CGJD8

642.00

60 in. / 1524 mm (1)
120 in. / 3048 mm (1)

9422CGJD9

720.00

100 A

788.00

Special Left-hand Mounted Single Cable Operating Mechanisms

Circuit Breaker Type

17-14

Cable Length
in. / mm (quantity)

Discount
Schedule

Cable Length
in. / mm
(quantity)

Catalog
Number

120 in. / 3048 mm (1)

9422CFAL10

36 in. / 914 mm (1)

9422CFAL30

60 in. / 1524 mm (1)

9422CFAL50

Frame Size
(max.)

$ Price
350.00

100 A

287.00
318.00

© 2012 Schneider Electric
All Rights Reserved

Disconnect Switch
Accessories

Flange Mounted, Variable Depth
Class 9422 / Refer to Catalog 9420CT9701

www.schneider-electric.us

Variable-Depth Mechanisms for Use with Square D™ Circuit Breakers and Schneider Electric™
(formerly Merlin Gerin™) Circuit Breakers
Use With

Circuit Breaker
Frame Size

No. of
Poles

Operating Mechanism

Variable-Depth Mtg.
Range Min.-Max.a
(Inches)

Frame Size
A

Operating Mechanism
Only—Does Not Include
Handle Mechanism
Type

$ Price

Operating Mechanism and Handle Mechanism
Includes Type A1
Handle Mechanism
Type

Includes Type A2
Handle Mechanism

$ Price

Type

$ Price

Square D Circuit Breakers
GJL

3

100

6.00–17.75

RG1

116.00

ARG11

257.00

ARG21

FAL, FHL

2–3

100

5.38–17.75

RN1

116.00

ARN11

257.00

ARN21

372.00

KAL, KHL

2–3

250

6.38–17.88

RP1

129.00

ARP11

270.00

ARP21

386.00

LALc, LHLc, Q4L

2–3

400

7.44–18.25

RR1

329.00

ARR11

471.00

ARR21

585.00

MEL, MXL

2–3

800

9.00–18.38

RT1

449.00

ART11

593.00

ART21

705.00

MAL, MHL

2–3

1200

9.00–18.38

RT1

449.00

ART11

593.00

ART21

705.00

NAL, NCL, NEL, NXL
2–3
1200
11.00–18.37
a
Class 9422 Type R2 will extend mounting depth 7 in.

RX1

513.00

—

Table 17.39:

Class

Type

—

131.00
243.00

Dimensions
Width
(A)

Height
(B)

Distance to Enclosure Flangea
(C)

Bracket Depth
(D)

Circuit Breaker
Frame Size

Type
in.

mm

in.

mm

in.

mm

in.

mm

in.

GJL

RG1

5.00

127

4.75

121

6.00

152

17.75

451

4.00

102

FAL, FHL

RN1

6.75

171

8.50

216

5.51

140

17.75

451

4.26

108
125

Minimum

Maximum
mm

KAL, KHL

RP1

7.13

181

10.13

257

6.51

165

17.88

454

4.94

LALc, LHLc, Q4L

RR1

10.19

259

11.00

279

7.44

189

18.25

464

6.00

152

MEL, MXL

RT1

13.38

340

14.00

356

9.00

229

18.38

467

9.69

246

MAL, MHLb

RT1

13.38

340

14.00

356

9.00

229

18.38

467

9.69

246

NAL, NCL, NEL, NXL

RX1

19.63

499

13.50

343

11.00

279

18.37

467

9.00

229

a
b

—

$ Price

Single Pole, Double Throw
9999
R26a
Double Pole, Double Throw
9999
R27a
a
Not for use with the GJL operating mechanism.

Table 17.40:

—

Electrical Interlocks—Class 9999

Description

9422R2 will extend the dimension by 7 in. Two required.
Minimum mounting depth when using MAL or MHL circuit breakers can be decreased to 7.63 inches by using the
Class 9422 Type RT1B conversion kit. $23.00
Warning: These operating mechanisms cannot be used with any LA / LH circuit breaker with an MB or MT suffix.

c

C = Distance from Outside of
Flange to Circuit Breaker
Mounting Surface

Enclosure Door

Enclosure Flange
D

CL
R.H. Handle

CL L.H. Handle

A

© 2012 Schneider Electric
All Rights Reserved

372.00

CP1

Minimum to wall or barrier.
Right- or left-hand mounting
to ensure adequate wire
bending space to lug
surface when maximum
wire size is used.
Refer to NEC Article 430-10.

Discount
Schedule

B

17-15

17

Table 17.38:

NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Designed for installation in custom built control enclosures where main or branch circuit protective devices are required. All
circuit breaker operating mechanisms are suitable for either right- or left-hand flange mounting, convertible on the job.

Disconnect Switch
Accessories

Flange Mounted, Variable Depth
Class 9422 / Refer to Catalog 9420CT9701

www.schneider-electric.us

17

Remote or Dual Adapter Kit
Switch

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

or
Breaker

For the remote or dual operation of GJL, FAL, FHL, KAL, KHL, LAL, LHL, Q4L, MAL, MHL,
MEL, and MXL circuit breakers.
Remote Operation—permits mounting the Class 9422 Type A9 or A10 handle mechanism
at a lower level than the disconnect device it controls. This arrangement is often required
where the disconnect device is mounted too high for personnel to easily reach a
conventional operator.
Dual Operation—permits controlling two disconnect devices, one in line with, and one
remote from, a single Class 9422 Type A9 or A10 handle mechanism.
NOTE: A Class 9422 Type A9 or A10 handle (see Digest 176 page 8-15) and the
preferred mounting method must be used.
Table 17.41:

Disconnect Device
Enclosure Mounting Depth

Remote operation shown
(handle mechanism not
included in kit)

Disconnect Device

Type
Min.

$ Price

Max.

Circuit Breaker
GJL

10.50

19.50

FAL, FHL

10.66

19.50

KAL, KHL

11.13

19.50

LAL, LHL, Q4L

12.13

19.88

MAL, MHL,MEL, MXL

13.75

20.25

Table 17.42:

D2

251.00

Air Valve Interlock

Note: Air valve interlocks only accept the specific three-way air valves, manufactured by Parker,
listed in the table below.
Parker Valve Model Numbera

Air valve interlock
mounted on enclosure

a

Air Valve Size

Knob Operated

0.50 NPT
13

M04841885

0.75 NPT
19

M04861885

M08541848
M08561848

Class 9422
Air Valve Interlock
Type

$ Price

G1

513.00

G2

513.00

1.00 NPT
M00080004
G1
513.00
25
Prices do not include air valves or handle mechanism. For more information on the
air valves listed above, contact Parker at c-parker@parker.com, or call 1-800-272-7537.

Table 17.43:
Accessory

Other Accessories
Description

Auxiliary kit recommended for use with 30 A and 60 A disconnect switches
Channel/Flange and FAL, FCL, FHL, KAL KHL, NSF, and NSJ circuit breaker mechanisms
when these devices are to be mounted on the center channel of a multi-door
Support Kit
enclosure or when extra rigidity for the flange is required. Supplied as

Class

Type

$ Price

9422

C1

42.80

Channel/Flange
Support Kit

Alternate Mounting Kit

Auxiliary Lock Plate

17-16

CP1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Reversing Drum Switches

Type A and B
Class 2601 / Refer to Catalog 2510CT9701

www.schneider-electric.us

Class 2601 reversing drum switches may be used for across-the-line starting and reversing of AC polyphase, AC single
phase or DC motors, where overload protection is not required or is provided separately. They are compact and
inexpensive but ruggedly constructed. Drum switches are field convertible from maintained-only to momentary-only
operation. This conversion consists of removing the handle screw and handle, turning the shaft 180 degrees, then
replacing the handle and handle screw.
Reversing Drum Switches

600 Vac Maximum

Class 2601

Ratings

NEMA Type 1
General Purpose
Enclosure

Maximum Horsepower
Voltage

Type AG2

360 Vdc Maximum

NEMA Type 4
Watertight and
Dusttight Enclosure

NEMA Type 1
Maintained &
Momentary a

NEMA Type 13
Oiltight
Flush Mounting

$ Price

Type

$ Price

158.00

AF2

131.00

AC
Single
Phase

AC
PolyPhase

DC

Type

$ Price

Type

$ Price

Type

115200/230
230
460/575

1-1/2
—
2
—

—
2
—
2

1/4
—
1/4
—

AG2

158.00

AW2

428.00

AG2S2

115200/230
230
460/575

1-1/2
—
3
5

—
5
—
7-1/2

2
—
2
—

BG1

428.00

BW1

590.00

—

a

—

—

17

Table 17.44:

—

Maintained – “Forward”; Momentary – “Reverse”; (not field convertible)

File E42243
CCN NLRV

File LR25490
Class 3211-05

Approximate Dimensions—Class 2601 Reversing Drum Switches
6.89

5.58

3.38

175

142

86

3.81
97

5.50

5.20
132 3.19

2.77

3.70

81

70

94

(2) 1/2" NPT
Pipe Thread

140

1.82
46

2.38

.20

2.87

(4) .17 Mounting Holes

60

Type AW2

3.20

5

73

.60

81

15

Types AW and BW

Type AF2

5.38
4.00 6.62
5.18

2.68

2.91

3.26

3.53

4.61
4.86

(2) K.O. For 1/ 2" Conduits
dimensions (inches) = AG/AH
BG

Types AG, BG

Dimensions:

Table 17.45:
•
•

© 2012 Schneider Electric
All Rights Reserved

in.
mm

How to Order

To Order Specify:

Catalog Number

Class Number
Type Number

Class

Type

2601

AG2

CP1

Discount
Schedule

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

NEMA Types 1, 3R, 4, and 13 Without Overload

17-17

Electromechanical
Reduced Voltage Starters

17
NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Reduced Voltage
Starting of Squirrel
Cage Motors

Electromechanical
Reduced Voltage
Starters

Table 17.46:

Description of All Types
Class 8600 / Refer to Catalog 8600CT9601

www.schneider-electric.us

A squirrel cage motor draws high starting current (inrush) and produces high starting torque when started at full voltage.
While these values differ for different motor designs, for a typical NEMA design B motor, the inrush will be approximately
600% of the motor full load amperage (FLA) rating, and the starting torque will be approximately 150% of full load torque at
full voltage. High current inrush and starting torque can cause problems in the electrical and mechanical systems, or may
even damage the materials being processed.
When a motor is started at reduced voltage, the current at the motor terminals is reduced in direct proportion to the voltage
reduction, while the torque is reduced by the square of the voltage reduction. If the “typical” NEMA B motor is started at 70%
of line voltage, the starting current would be 70% of the full voltage value (that is, 0.70 x 600% = 420% FLA). The torque
would then be (0.70)2 or 49% of the normal starting torque (that is, 0.49 x 150% = 74% full load torque). Therefore, reduced
voltage starting provides an effective means of reducing both inrush current and starting torque.
If the motor has a high inertia or if the motor rating is marginal for the applied load, reducing the starting torque may prevent
the motor from reaching full speed before the thermal overload relays trip. Applications that require high starting torque
should be reviewed to determine if reduced voltage starting is suitable.
Square D™ offers several types of electromechanical as well as solid-state reduced voltage starters that provide different
starting characteristics. The following describes the 8600 series of reduced voltage starters.
Class 8606—Autotransformer Starter: Autotransformer starters provide reduced voltage to the motor terminals
during starting through the use of a tapped, three phase autotransformer. Taps on the autotransformer allow for
selection of the motor with 50%, 65%, or 80% of line voltage values supplying 50%, 65%, or 80% of the current inrush
seen during a full voltage start. The resulting starting torque will be 25%, 42%, or 64% of full voltage values, as will be
the current draw on the line. Thus, the autotransformer provides the maximum torque with minimum line current.
Class 8630—Wye-Delta Starter: Wye-delta starters can only be used on wye-delta motors which have six leads that
allow for motor winding to be connected in either a wye or delta configuration. During start up, the windings are
connected in the wye, resulting in 58% of line voltage applied across two windings. This reduces both inrush and
starting torque to 33% of the delta connected values. After a set time delay, the motor leads are switched to the delta
connection. The wye-delta starter is available in both open and closed transition configurations. Closed transition
starters are supplied with an additional contactor and resistor bank used to keep the motor windings energized for a
few cycles until the transition from wye to delta is complete.
Class 8640—Part Winding Starter: Part winding starters can be used only with part winding motors. During a part winding
start, only one winding is energized, reducing the inrush current to 60–70% (depending on the motor design) and starting
torque to 50% of normal starting values with both windings energized. Most (but not all) dual voltage 230/460 volt motors are
suitable for part winding starts at 230 volts.

Starter Characteristics

Characteristic

Full Voltage

Autotransformer, Class 8606

Wye-Delta Class, 8630

Part Winding, Class 8640

Voltage at Motor

100%

50% / 65% / 80% (tap setting)

100%

100%

Ramped Up

Line Current (% Full Load Current)

600%

150% / 250% / 380%

200%

390%

150% to 700% (adjustable)

Starting Torque (% Rated Torque)

150%

40% / 60% / 100%

50%

70%

0% to 100% (adjustable)

Start Time (Factory Setting)

—

6–7 seconds

10 seconds / 15 seconds
(open/closed transition)

1–1.5 seconds

10 seconds
(adjustable 1–60 seconds)

Advantages

•
•
•

Simple
Economical
High Starting Torque

•
•
•

High torque/amperage
High inertial loads
Flexibility

•
•
•

High inertial loads
Long acceleration loads
Good torque/amperage

Disadvantages

•
•

Abrupt starts
Large current inrush

•

Large size

•
•

Low torque
No flexibility

Motor

Standard

How to Order
Note: Tables 17.47 and 17.48 are
for 60 Hz; see Table 17.51
for 50 Hz codes.

Table 17.47:

1.
2.
3.

Standard

Special

Table 17.48:

Coil Voltage Codes

Greatest flexibility
Smooth ramp
Solid-state overload relay
Diagnostics
SCR heat dissipation
Ambient limitations

Standard

Table 17.49:

Control

Code

Line

Control

Code

208
240
380
480
600

208
240
380
480
600

V08
V03
V05
V06
V07

208
240
240
480
480
480
600
380
other

120
24
120
24
120
240
120
110/50
specify

V84
V82
V80
V83
V81
V87
V86
V95
V99

17-18

•
•
•
•
•
•

Specify the Class Number and the Type Number.
If all coils are at the line voltage, and not Sizes 6 or 7, select the voltage code from Table 17.47 (Sizes 6 and 7 are supplied with a
fused transformer with 120 Vac as standard).
If the coils are at a different voltage than line supply, or Size 6 or 7, select a voltage code from Table 17.48 and also select a Form
code from Table 17.49 (note that a Form code may be used with any voltage code, except as noted).

Line Voltage Codes

50 Hz Control
Voltage

Simple
Small size

Not suitable for:
• High inertial loads
• Frequent starting

Special

Line

380 Vac, 50 Hz
Starters

•
•

Solid-State ATS46

Table 17.50:

Form Codes

Form Description
Fused CPT for timing relay only
Fused CPT for all coils
Separate control of timing relay only
Separate control for all coils
b
c

Form Code
F4T
F4T40
S
Y195

See Table 17.50 for sizing of 380 V starters.
24 V coils are not available on Sizes 4–7.

380 Vac, 50 Hz Starters, Maxiumum Horsepower Rating

Autotransformer, Class 8606

Wye-Delta, Class 8630

Part Winding, Class 8640

Max. hp

NEMA Size

Max. hp

NEMA Size

Max. hp

NEMA Size

—
25
50
75
150
300

—
2
3
4
5
6

15
40
75
150
250
500

1YD
2YD
3YD
4YD
5YD
6YD

15
40
75
125
250
500

1PW
2PW
3PW
4PW
5PW
6PW

Table 17.51:
Hz

Voltage

60
50

120
110

The Class 8600 starters are available for 380 Vac,
50 Hz applications. Table 17.50 provides maximum
horsepower ratings. To determine the Type Number,
select the second digit based on NEMA size. Select the
fifth digit based on the horsepower requirement. Specify
V05 voltage code. List prices for the same NEMA size
starter apply.

Coil Voltages
Code

Voltage

V02

240
220

Code

Voltage

V03

480
440

Code

Voltage

Code

V06

600
550

V07

The starters in this section can also be operated at
50 Hz at the coil voltages listed in Table 17.51.
For additional coil voltage availability, contact the
Customer Care Center (CCC) at 1-888-778-2733.

© 2012 Schneider Electric
All Rights Reserved

Electromechanical
Reduced Voltage Starters

Autotransformer Starters

NOTE: Prices shown do not include thermal units. Devices require 3 thermal units
(Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176
page 16-116 for selection information.
Table 17.52:
Motor
Voltage
(Starter
Voltage)

3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz
NEMA Type 4a
Watertight and
Dusttight Enclosure

NEMA Type 12/3Rd
Dusttight & Driptight
Industrial Use Enclosure

O.E.M. Kit c

Open Type

NEMA
Size

10

2

SDG1C

8076.00

SDW1C

12491.00

SDA1C

10641.00

SDO1C

7734.00

SDK1C

6786.00

15
20
25

3

SEG1D
SEG1E
SEG1F

9500.00

SEW1D
SEW1E
SEW1F

13914.00

SEA1D
SEA1E
SEA1F

13707.00

SEO1D
SEO1E
SEO1F

8418.00

SEK1D
SEK1E
SEK1F

7493.00

30
40

4

SFG1G
SFG1H

18417.00

SFW1G
SFW1H

26535.00

SFA1G
SFA1H

21834.00

SFO1G
SFO1H

16848.00

SFK1G
SFK1H

13181.00
23223.00

Typeb

200
(208)

50
75

230
(240)

$ Price

Typeb

$ Price

Typeb

$ Price

Typeb

$ Price

Typeb

$ Price

5

SGG1J
SGG1L

30330.00

SGW1J
SGW1L

38448.00

SGA1J
SGA1L

34176.00

SGO1J
SGO1L

27167.00

SGK1J
SGK1L

100
125
150

6

SHG1M
SHG1N
SHG1P

56507.00

SHW1M
SHW1N
SHW1P

67190.00

SHA1M
SHA1N
SHA1P

61848.00

SHO1M
SHO1N
SHO1P

51438.00

SHK1M
SHK1N
SHK1P

41481.00

10
15

2

SDG1C
SDG1D

8076.00

SDW1C
SDW1D

12491.00

SDA1C
SDA1D

10641.00

SDO1C
SDO1D

7734.00

SDK1C
SDK1D

6786.00

20
25
30

3

SEG1E
SEG1F
SEG1G

9500.00

SEW1E
SEW1F
SEW1G

13914.00

SEA1E
SEA1F
SEA1G

12207.00

SEO1E
SEO1F
SEO1G

8418.00

SEK1E
SEK1F
SEK1G

7493.00

40
50

4

SFG1H
SFG1J

18417.00

SFW1H
SFW1J

26535.00

SFA1H
SFA1J

21834.00

SFO1H
SFO1J

16848.00

SFK1H
SFK1J

13181.00

27167.00

SGK1L
SGK1M

23223.00

51438.00

SHK1N
SHK1P
SHK1Q

41481.00

75
100

460
(480)
/
575
(600)

a
b
c
d

NEMA Type 1
General Purpose
Enclosure

Max.
HP

5

SGG1L
SGG1M

30330.00

SGW1L
SGW1M

38448.00

SGA1L
SGA1M

34176.00

SGO1L
SGO1M

125
150
200

6

SHG1N
SHG1P
SHG1Q

56507.00

SHW1N
SHW1P
SHW1Q

67190.00

SHA1N
SHA1P
SHA1Q

61848.00

SHO1N
SHO1P
SHO1Q

250
300

7

SJG1R
SJG1S

96786.00

SJW1R
SJW1S

107468.00

SJA1R
SJA1S

102126.00

—

10
15
20
25

2

SDG1C
SDG1D
SDG1E
SDG1F

8076.00

SDW1C
SDW1D
SDW1E
SDW1F

12491.00

SDA1C
SDA1D
SDA1E
SDA1F

10641.00

SDO1C
SDO1D
SDO1E
SDO1F

30
40
50

3

SEG1G
SEG1H
SEG1J

9500.00

SEW1G
SEW1H
SEW1J

13914.00

SEA1G
SEA1H
SEA1J

12207.00

60
75
100

4

SFG1K
SFG1L
SFG1M

18417.00

SFW1K
SFW1L
SFW1M

26535.00

SFA1K
SFA1L
SFA1M

125
150
200

5

SGG1N
SGG1P
SGG1Q

30330.00

SGW1N
SGW1P
SGW1Q

38448.00

250
300
400

6

SHG1R
SHG1S
SHG1T

56507.00

SHW1R
SHW1S
SHW1T

500
600

7

SJG1U
SJG1W

96786.00

SJW1U
SJW1W

—

—

—

7734.00

SDK1C
SDK1D
SDK1E
SDK1F

6786.00

SEO1G
SEO1H
SEO1J

8418.00

SEK1G
SEK1H
SEK1J

7493.00

21834.00

SFO1K
SFO1L
SFO1M

16848.00

SFK1K
SFK1L
SFK1M

13181.00

SGA1N
SGA1P
SGA1Q

34176.00

SGO1N
SGO1P
SGO1Q

27167.00

SGK1N
SGK1P
SGK1Q

23223.00

67190.00

SHA1R
SHA1S
SHA1T

61848.00

SHO1R
SHO1S
SHO1T

51438.00

SHK1R
SHK1S
SHK1T

41481.00

107468.00

SJA1U
SJA1W

102126.00

SJO1W

88250.00

—

—

NEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost.Specify as Form G17. See “Modifications & Forms” for price adder.
Both line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering.
No factory modifications (Forms) are available with O.E.M. Kit.
NEMA Type 12 enclosures can be field modified for outdoor non-corrosive and non-service entrance rated applications.

Note: Class 8606 starters are supplied with a NEMA style medium duty autotransformer.
Medium duty service includes applications to motors which drive loads such as fans, pumps, compressors, and line shafts.
NEMA Sizes 2–5: Autotransformer is rated for fifteen 15-second starts per hour.
NEMA Sizes 6–7: Autotransformer is rated for three 30-second starts per hour.
Contact the Customer Care Center (CCC) at 1-888-778-2733 for applications which require frequent starting or jogging, or have extremely high inertia.

OL
2S

L1

OL

T2

OL

T3

2S
100
80
65
50
0

2S

L3

R

1S

Motor

•
•
•
•

TR

1S
R

Catalog Number

Class Number
Type Number
Voltage Code
Form(s)e

Class

Type

Voltage Code

Form(s)

8606

SFG1M

V81

S

Description: 100 hp, 480 V line, 120 V separate control, 60 Hz
e

TR

How to Order

To Order Specify:

1S

R

L2

Table 17.53:

T1

100
80
65
50
0

R

Forms need to be specified only if any of the coils are at a different voltage than line supply (V8•).
See page 17-18 for a fuller explanation of how to order; this page also provides the necessary
coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications.

R
1S
1S

2S

2S
To
2 Wire Control Separate
Device (If used) Control
Stop 2 Start
3
1
TR
TR

OL

Typical Autotransformer Starter
Sizes 2–5
Separate Control (Form S)
© 2012 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

17-19

17

www.schneider-electric.us

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Class 8606 / Refer to Catalog 8600CT9601

Electromechanical
Reduced Voltage Starters

Wye-Delta Starters (Open Transition)
Class 8630 / Refer to Catalog 8600CT9601

www.schneider-electric.us

17

NOTE: Prices shown do not include thermal units. Devices require 3 thermal units
(Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176 page
16-116 for selection information.

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Table 17.54: 3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz
Motor
Voltage
(Starter
Voltage)

Max.
HP

NEMA Type 1
General Purpose
Enclosure

NEMA
Size

NEMA Type 4a
Watertight and
Dusttight Enclosure
(Stainless Steel 1YD-4YD)

NEMA Type 12/3Rd
Dusttight & Driptight
Industrial Use Enclosure

Open Type

O.E.M. Kit c

Typeb
$ Price
Typeb
$ Price
Typeb
$ Price
Typeb
$ Price
Typeb
10
1YD
SCG1C
4892.00
SCW1C
6602.00
SCA1C
6317.00
SCO1C
4806.00
—
15
SDG1D
SDW1D
SDA1D
SDO1D
2YD
5790.00
7713.00
7569.00
5562.00
—
20
SDG1E
SDW1E
SDA1E
SDO1E
25
SEG1F
SEW1F
SEA1F
SEO1F
SEK1F
30
3YD
SEG1G
8424.00
SEW1G
11204.00
SEA1G
10562.00
SEO1G
7542.00
SEK1G
40
SEG1H
SEW1H
SEA1H
SEO1H
SEK1H
50
SFG1J
SFW1J
SFA1J
SFO1J
SFK1J
200
4YD
17568.00
21941.00
20417.00
15987.00
60
SFG1K
SFW1K
SFA1K
SFO1K
SFK1K
(208)
75
SGG1L
SGW1L
SGA1L
SGO1L
SGK1L
100
SGG1M
SGW1M
SGA1M
SGO1M
SGK1M
5YD
31584.00
39702.00
35429.00
28422.00
125
SGG1N
SGW1N
SGA1N
SGO1N
SGK1N
150
SGG1P
SGW1P
SGA1P
SGO1P
SGK1P
200
SHG1Q
SHW1Q
SHA1Q
SHO1Q
SHK1Q
250
6YD
SHG1R
67589.00
SHW1R
78272.00
SHA1R
72930.00
SHO1R
62519.00
SHK1R
300
SHG1S
SHW1S
SHA1S
SHO1S
SHK1S
10
1YD
SCG1C
4892.00
SCW1C
6602.00
SCA1C
6317.00
SCO1C
4806.00
—
15
SDG1D
SDW1D
SDA1D
SDO1D
20
2YD
SDG1E
5790.00
SDW1E
7713.00
SDA1E
7569.00
SDO1E
5562.00
—
25
SDG1F
SDW1F
SDA1F
SDO1F
30
SEG1G
SEW1G
SEA1G
SEO1G
SEK1G
40
3YD
SEG1H
8424.00
SEW1H
11204.00
SEA1H
10562.00
SEO1H
7542.00
SEK1H
50
SEG1J
SEW1J
SEA1J
SEO1J
SEK1J
60
SFG1K
SFW1K
SFA1K
SFO1K
SFK1K
230
4YD
17568.00
21941.00
20417.00
15987.00
75
SFG1L
SFW1L
SFA1L
SFO1L
SFK1L
(240)
100
SGG1M
SGW1M
SGA1M
SGO1M
SGK1M
125
5YD
SGG1N
31584.00
SGW1N
39702.00
SGA1N
35429.00
SGO1N
28422.00
SGK1N
150
SGG1P
SGW1P
SGA1P
SGO1P
SGK1P
200
SHG1Q
SHW1Q
SHA1Q
SHO1Q
SHK1Q
250
6YD
SHG1R
67589.00
SHW1R
78272.00
SHA1R
72930.00
SHO1R
62519.00
SHK1R
300
SHG1S
SHW1S
SHA1S
SHO1S
SHK1S
400
SJG1T
SJW1T
SJA1T
SJO1T
7YD
91160.00
101843.00
96501.00
86090.00
—
500
SJG1U
SJW1U
SJA1U
SJO1U
10
SCG1C
SCW1C
SCA1C
SCO1C
1YD
4892.00
6602.00
6317.00
4806.00
—
15
SCG1D
SCW1D
SCA1D
SCO1D
20
SDG1E
SDW1E
SDA1E
SDO1E
25
SDG1F
SDW1F
SDA1F
SDO1F
2YD
5790.00
7713.00
7569.00
5562.00
—
30
SDG1G
SDW1G
SDA1G
SDO1G
40
SDG1H
SDW1H
SDA1H
SDO1H
SEW1J
SEA1J
SEO1J
SEK1J
50
SEG1J
SEW1K
11204.00
SEA1K
10562.00
SEO1K
7542.00
SEK1K
60
3YD
SEG1K
8424.00
460
SEW1L
SEA1L
SEO1L
SEK1L
75
SEG1L
(480)
100
SFG1M
SFW1M
SFA1M
SFO1M
SFK1M
/
125
4YD
SFG1N
17568.00
SFW1N
21941.00
SFA1N
20417.00
SFO1N
15987.00
SFK1N
575
150
SFG1P
SFW1P
SFA1P
SFO1P
SFK1P
(600)
200
SGG1Q
SGW1Q
SGA1Q
SGO1Q
SGK1Q
250
5YD
SGG1R
31584.00
SGW1R
39702.00
SGA1R
35429.00
SGO1R
28422.00
SGK1R
300
SGG1S
SGW1S
SGA1S
SGO1S
SGK1S
400
SHG1T
SHW1T
SHA1T
SHO1T
SHK1T
500
6YD
SHG1U
67589.00
SHW1U
78272.00
SHA1U
72930.00
SHO1U
62519.00
SHK1U
600
SHG1W
SHW1W
SHA1W
SHO1W
SHK1W
800
SJG1Y
SJW1Y
SJA1Y
SJO1Y
7YD
91160.00
101843.00
96501.00
86090.00
—
1000
SJG1Z
SJW1Z
SJA1Z
SJO1Z
a
NEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost. Specify as Form G17. See page 17-32 for price adder.
b
Both line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering.
c
No Factory Modifications (Forms) available with O.E.M. Kit.
d
NEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information.

L1
L2
L3

1M

OL

T1

1M

OL

T2

1M

OL

T3

Table 17.55:
T2

Motor
T1 T5

2M

T5

2M

S

T4

2M

S

T6

TR

TR

2M

S
1M

T6

T3

•
•
•
•

6596.00
9300.00
18530.00

39347.00
—
—
6596.00
9300.00
18530.00
39347.00
—
—
—

6596.00
9300.00
18530.00
39347.00
—

Catalog Number

Class Number
Type Number
Voltage Code
Form(s)e
e

—

How to Order

To Order Specify:
T4

$ Price
—

Class

Type

Voltage Code

8630

SFG1M

V06

Form(s)

Description: 100 hp, 480 V line, 480 V common control, 60 Hz
Forms need to be specified only if any of the coils are at a different voltage than line supply (V8•).
See page 17-18 for a fuller explanation of how to order; this page also provides the necessary
coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications.
Refer to page 17-32 for other factory modifications (Forms).

S

1M

S

2 Wire Control Device (If used)
Start
1 Stop 2
3

2M

TR

OL

TR

Typical Wye-Delta Starter Sizes 1–4 (Open Transition)
Common Control (Standard)

17-20

CP1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Electromechanical
Reduced Voltage Starters

Wye-Delta Starters (Closed Transition)

NOTE: Prices shown do not include thermal units. Devices require 3 thermal units
(Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176 page
16-116 for selection information.

Motor
Voltage
(Starter
Voltage)

3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz
Max.
HP

NEMA Type 4d
Watertight and
Dusttight Enclosure
(Stainless Steel 1YD-4YD)

NEMA Type 1
General Purpose
Enclosure

NEMA
Size

NEMA Type 12/3Rc
Dusttight & Driptight
Industrial Use Enclosure

Open Type

O.E.M. Kit b

Typea
$ Price
Typea
$ Price
Typea
$ Price
Typea
$ Price
Typea
10
1YD
SCG2C
7470.00
SCW2C
9180.00
SCA2C
8895.00
SCO2C
7385.00
—
15
SDG2D
SDW2D
SDA2D
SDO2D
2YD
8454.00
10376.00
10233.00
8226.00
—
20
SDG2E
SDW2E
SDA2E
SDO2E
25
SEG2F
SEW2F
SEA2F
SEO2F
SEK2F
30
3YD
SEG2G
11672.00
SEW2G
14450.00
SEA2G
13809.00
SEO2G
10790.00
SEK2G
40
SEG2H
SEW2H
SEA2H
SEO2H
SEK2H
50
SFG2J
SFW2J
SFA2J
SFO2J
SFK2J
200
4YD
22995.00
27368.00
25844.00
21414.00
60
SFG2K
SFW2K
SFA2K
SFO2K
SFK2K
(208)
75
SGG2L
SGW2L
SGA2L
SGO2L
SGK2L
100
SGG2M
SGW2M
SGA2M
SGO2M
SGK2M
5YD
38363.00
46481.00
42209.00
35202.00
125
SGG2N
SGW2N
SGA2N
SGO2N
SGK2N
150
SGG2P
SGW2P
SGA2P
SGO2P
SGK2P
200
SHG2Q
SHW2Q
SHA2Q
SHO2Q
SHK2Q
250
6YD
SHG2R
85022.00
SHW2R
95702.00
SHA2R
90363.00
SHO2R
79950.00
SHK2R
300
SHG2S
SHW2S
SHA2S
SHO2S
SHK2S
10
1YD
SCG2C
7470.00
SCW2C
9180.00
SCA2C
8895.00
SCO2C
7385.00
—
15
SDG2D
SDW2D
SDA2D
SDO2D
—
20
2YD
SDG2E
8454.00
SDW2E
10376.00
SDA2E
10233.00
SDO2E
8226.00
—
25
SDG2F
SDW2F
SDA2F
SDO2F
—
30
SEG2G
SEW2G
SEA2G
SEO2G
SEK2G
40
3YD
SEG2H
11672.00
SEW2H
14450.00
SEA2H
13809.00
SEO2H
10790.00
SEK2H
50
SEG2J
SEW2J
SEA2J
SEO2J
SEK2J
60
SFG2K
SFW2K
SFA2K
SFO2K
SFK2K
230
4YD
22995.00
27368.00
25844.00
21414.00
75
SFG2L
SFW2L
SFA2L
SFO2L
SFK2L
(240)
100
SGG2M
SGW2M
SGA2M
SGO2M
SGK2M
125
5YD
SGG2N
38363.00
SGW2N
46481.00
SGA2N
42209.00
SGO2N
35202.00
SGK2N
150
SGG2P
SGW2P
SGA2P
SGO2P
SGK2P
200
SHG2Q
SHW2Q
SHA2Q
SHO2Q
SHK2Q
250
6YD
SHG2R
85022.00
SHW2R
95702.00
SHA2R
90363.00
SHO2R
79950.00
SHK2R
300
SHG2S
SHW2S
SHA2S
SHO2S
SHK2S
400
SJG2T
SJW2T
SJA2T
SJO2T
—
7YD
118206.00
128888.00
123548.00
113135.00
500
SJG2U
SJW2U
SJA2U
SJO2U
—
10
SCG2C
SCW2C
SCA2C
SCO2C
—
1YD
7470.00
9180.00
8895.00
7385.00
15
SCG2D
SCW2D
SCA2D
SCO2D
—
20
SDG2E
SDW2E
SDA2E
SDO2E
—
25
SDG2F
SDW2F
SDA2F
SDO2F
—
2YD
8454.00
10376.00
10233.00
8226.00
30
SDG2G
SDW2G
SDA2G
SDO2G
—
40
SDG2H
SDW2H
SDA2H
SDO2H
—
50
SEG2J
SEW2J
SEA2J
SEO2J
SEK2J
60
3YD
SEG2K
11672.00
SEW2K
14450.00
SEA2K
13809.00
SEO2K
10790.00
SEK2K
460
75
SEG2L
SEW2L
SEA2L
SEO2L
SEK2L
(480)
100
SFG2M
SFW2M
SFA2M
SFO2M
SFK2M
/
125
4YD
SFG2N
22995.00
SFW2N
27368.00
SFA2N
25844.00
SFO2N
21414.00
SFK2N
575
150
SFG2P
SFW2P
SFA2P
SFO2P
SFK2P
(600)
200
SGG2Q
SGW2Q
SGA2Q
SGO2Q
SGK2Q
250
5YD
SGG2R
38363.00
SGW2R
46481.00
SGA2R
42209.00
SGO2R
35202.00
SGK2R
300
SGG2S
SGW2S
SGA2S
SGO2S
SGK2S
400
SHG2T
SHW2T
SHA2T
SHO2T
SHK2T
500
6YD
SHG2U
85022.00
SHW2U
95702.00
SHA2U
90363.00
SHO2U
79950.00
SHK2U
700
SHG2W
SHW2W
SHA2W
SHO2W
SHK2W
800
SJG2Y
SJW2Y
SJA2Y
SJO2Y
—
7YD
118206.00
128888.00
123548.00
113135.00
1000
SJG2Z
SJW2Z
SJA2Z
SJO2Z
—
a
Both line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering.
b
No Factory Modifications (Forms) available with O.E.M. Kit.
c
NEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information.
d
NEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost. Specify as Form G17. See page 17-32 for price adder.

1M

L1

OL
OL

1M

L2

1M

L3

2 Wire Control
Device (If used)

T2
T4 T2

T3

Motor

R
E
S

R
E
S

T1 T5

R
E
S

T6

2M

1S

T4

2M

1S

T5

T6

•
•
•
•
e

(HI) PRI
PT
(X1) SEC (X2)
GND (If used)
Start
OL
3
1 Stop 2

10142.00
13931.00
25181.00

50319.00
—
—
10142.00
13931.00
25181.00
50319.00
—
—
—

10142.00
13931.00
25181.00
50319.00
—

Catalog Number

Class Number
Type Number
Voltage Code
Form(s)e

T3

—

How to Order

To Order Specify:

2S

2S
2M

OL

2S

Table 17.57:

T1

$ Price
—

17

Table 17.56:

Class

Type

Voltage Code

Form(s)

8630

SFG1M

V81

F4T40

Description: 100 hp, 480 V line, 120 V separate control, 60 Hz
Forms need to be specified only if any of the coils are at a different voltage than line supply (V8 •).
See page 17-18 for a fuller explanation of how to order; this page also provides the necessary
coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications.
Refer to page 17-32 for other factory modifications (Forms).

TR

2S

TR
TR

2M

1S
1M

TR

1S
2S
1M

1S

2M

Typical Wye-Delta Starter
Sizes 1–4 (Closed Transition)
Fused Control Transformer (Form F4T40)

© 2012 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Class 8630 / Refer to Catalog 8600CT9601

www.schneider-electric.us

17-21

Electromechanical
Reduced Voltage Starters

Part Winding Starters
Class 8640 / Refer to Catalog 8600CT9601

www.schneider-electric.us

17

NOTE: Prices shown do not include thermal units. Devices require 6 thermal units
(Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176
page 16-116 for selection information.

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Table 17.58:
Motor
Voltage
(Starter
Voltage)

3-Pole Polyphase—600 Vac Maximum—50–60 Hz
Max.
HP

Typeb

a
b
c
d

Typeb

$ Price

Typeb

O.E.M. Kit c

Open Type

$ Price

Typeb

$ Price

Typeb

$ Price

1PW

SCG1C

3119.00

SCW1C

4829.00

SCA1C

4544.00

SCO1C

3033.00

—

15
20

2PW

SDG1D
SDG1E

4445.00

SDW1D
SDW1E

6368.00

SDA1D
SDA1E

6224.00

SDO1D
SDO1E

4217.00

SDK1D
SDK1E

2685.00

25
30
40

3PW

SEG1F
SEG1G
SEG1H

6267.00

SEW1F
SEW1G
SEW1H

9045.00

SEA1F
SEA1G
SEA1H

8405.00

SEO1F
SEO1G
SEO1H

5868.00

SEK1F
SEK1G
SEK1H

4359.00

50
60
75

4PW

SFG1J
SFG1K
SFG1L

13404.00

SFW1J
SFW1K
SFW1L

17775.00

SFA1J
SFA1K
SFA1L

16253.00

SFO1J
SFO1K
SFO1L

12662.00

SFK1J
SFK1K
SFK1L

8217.00

100
125
150

5PW

SGG1M
SGG1N
SGG1P

28071.00

SGW1M
SGW1N
SGW1P

36192.00

SGA1M
SGA1N
SGA1P

31919.00

SGO1M
SGO1N
SGO1P

26505.00

SGK1M
SGK1N
SGK1P

18621.00

10

—

1PW

SCG1C

3119.00

SCW1C

4829.00

SCA1C

4544.00

SCO1C

3033.00

—

15
20
25

2PW

SDG1D
SDG1E
SDG1F

4445.00

SDW1D
SDW1E
SDW1F

6368.00

SDA1D
SDA1E
SDA1F

6224.00

SDO1D
SDO1E
SDO1F

4217.00

SDK1D
SDK1E
SDK1F

2685.00

30
40
50

3PW

SEG1G
SEG1H
SEG1J

6267.00

SEW1G
SEW1H
SEW1J

9045.00

SEA1G
SEA1H
SEA1J

8405.00

SEO1G
SEO1H
SEO1J

5868.00

SEK1G
SEK1H
SEK1J

4359.00

60
75

4PW

SFG1K
SFG1L

13404.00

SFW1K
SFW1L

17775.00

SFA1K
SFA1L

16253.00

SFO1K
SFO1L

12662.00

SFK1K
SFK1L

8217.00

100
125
150

5PW

SGG1M
SGG1N
SGG1P

28071.00

SGW1M
SGW1N
SGW1P

36192.00

SGA1M
SGA1N
SGA1P

31919.00

SGO1M
SGO1N
SGO1P

26505.00

SGK1M
SGK1N
SGK1P

18621.00

200
250
300

6PW

SHG1Q
SHG1R
SHG1S

58694.00

SHW1Q
SHW1R
SHW1S

67338.00

SHA1Q
SHA1R
SHA1S

65816.00

SHO1Q
SHO1R
SHO1S

53622.00

—

—

400

7PW

SJG1T

89672.00

SJW1T

98865.00

SJA1T

98217.00

SJO1T

80699.00

—

—

10
15

1PW

SCG1C
SCG1D

3119.00

SCW1C
SCW1D

4829.00

SCA1C
SCA1D

4544.00

SCO1C
SCO1D

3033.00

—
—

—

20
25
30
40

2PW

SDG1E
SDG1F
SDG1G
SDG1H

4445.00

SDW1E
SDW1F
SDW1G
SDW1H

6368.00

SDA1E
SDA1F
SDA1G
SDA1H

6224.00

SDO1E
SDO1F
SDO1G
SDO1H

4217.00

SDK1E
SDK1F
SDK1G
SDK1H

2685.00

50
60
75

3PW

SEG1J
SEG1K
SEG1L

6267.00

SEW1J
SEW1K
SEW1L

9045.00

SEA1J
SEA1K
SEA1L

8405.00

SEO1J
SEO1K
SEO1L

5868.00

SEK1J
SEK1K
SEK1L

4359.00

100
125
150

4PW

SFG1M
SFG1N
SFG1P

13404.00

SFW1M
SFW1N
SFW1P

17775.00

SFA1M
SFA1N
SFA1P

16253.00

SFO1M
SFO1N
SFO1P

12662.00

SFK1M
SFK1N
SFK1P

8217.00

200
250
350

5PW

SGG1Q
SGG1R
SGG1S

28071.00

SGW1Q
SGW1R
SGW1S

36192.00

SGA1Q
SGA1R
SGA1S

31919.00

SGO1Q
SGO1R
SGO1S

26505.00

SGK1Q
SGK1R
SGK1S

18621.00

400
500
600

6PW

SHG1T
SHG1U
SHG1W

58694.00

SHW1T
SHW1U
SHW1W

67338.00

SHA1T
SHA1U
SHA1W

65816.00

SHO1T
SHO1U
SHO1W

53622.00

—

—

700
800

7PW

SJG1X
SJG1Y

89672.00

SJW1X
SJW1Y

98865.00

SJA1X
SJA1Y

98217.00

SJO1X
SJO1Y

80699.00

—
—

—

230
(240)

460
(480)
/
575
(600)

$ Price

NEMA Type 12/3Rd
Dusttight & Driptight
Industrial Use Enclosure

10

200
(208)

460
(480)
/
575
(600)

NEMA Type 4a
Watertight and
Dusttight Enclosure
(Stainless Steel 1PW–4PW)

NEMA Type 1
General Purpose
Enclosure

NEMA
Size

—

NEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost. Specifiy as Form G17. See page 17-32 for price adder.
Both line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering.
No Factory Modifications (Forms) available with O.E.M. Kit.
NEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information.

Table 17.59:
L1
L2
L3

S

OL2

S

OL2

S

OL2

S

OL1

R

OL1

R

OL1

TR

Stop

2

Start

B
C
To Motor

•
•
•
•

E
F

Catalog Number

Class Number
Type Number
Voltage Code
Form(s)e
e

Class

Type

Voltage Code

Form(s)

8640

SFG1M

V06

C

Description: 100 hp, 480 V line, 480 V common control, 60 Hz
Forms need to be specified only if any of the coils are at a different voltage than line supply (V8•).
See page 17-18 for a fuller explanation of how to order; this page also provides the necessary
coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications.
Refer to page 17-32 for other factory modifications (Forms).

S

2 Wire Control
Device (If used)
1

To Order Specify:

A

D

How to Order

TR
3

S

R
TR

OL1 OL2

TR

Typical Part Winding
Sizes 1–4
Common Control (Standard)

17-22

CP1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Electromechanical
Reduced Voltage Starters

Approximate Dimensions
Class 8606, 8630, 8640 / Refer to Catalog 8600CT9601

www.schneider-electric.us

Approximate Dimensions—Not for Construction
Class 8606—Autotransformer
NEMA Type 1 / 12 Enclosure
NEMA
Size

2

3 or 4

5

Class 8606
Autotransformer
6

Table 17.61:
NEMA
Size

1YD
or
2YD
3YD
or
4YD
5YD
or
6YD

Class 8630
Wye-Delta

Table 17.62:
NEMA
Size

1YD
or
2YD
3YD
or
4YD
5YD
or
6YD

Table 17.63:

Open

Dim.

H
W
D
H
W
D
H
W
D
H
W
D

in.

mm

43
22
8
63
28
9
63
28
9
56
30
14

1092
559
203
1600
711
229
1600
711
229
1422
762
354

Non-Combo or Combo
with Circuit Breaker
in.
mm
52
25
10
70b
32
16
70b
32
16
90b
34
20

1320
635
254
1778
813
406
1778
813
406
2286
864
508

NEMA Type 4 Enclosure

Combo
with Disconnect Switch
in.
mm
52
25
10
70b
32
16
90b
36
16
90b
64
24

1320
635
254
1778
813
406
2286
914
406
2286
1626
610

Non-Combo or Combo
with Circuit Breaker
in.
mm
52
25
10
75b
32
16
75b
32
16
98b
34
20

1320
635
254
1778
813
406
1778
813
406
2489
864
508

Combo
with Disconnect Switch
in.
mm
52
25
10
75b
32
16
95b
36
16
98b
64
24

1320
635
254
1778
813
406
2413
914
406
2489
1626
610

Class 8630—Wye-Delta, Open Transition
NEMA Type 1 / 12 Enclosure

Open

Dim.

Non-Combo

NEMA Type 4 Enclosure

Combo

Non-Combo

Combo

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

H
W
D
H
W
D
H

21
21
7
42
25
7
62

553
553
178
1067
635
178
1576

25
23
8
48
28
8
90b

635
584
203
1219
712
203
2286

25
23
8
49
30
11
90b

635
584
203
1245
762
279
2286

25
23
8
48
28
8
98b

635
584
203
1219
712
203
2489

—
—
—
49
30
11
98b

—
—
—
1245
762
279
2489

W
D

29
10

737
254

36
16

914
406

36
16

914
406

36
16

914
406

36
16

914
406

Class 8630—Wye-Delta, Closed Transition
NEMA Type 1 / 12 Enclosure

Open

Dim.

H
W
D
H
W
D
H
W
D

Non-Combo

NEMA Type 4 Enclosure

Combo

Non-Combo

Combo

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

21
21
14
42
25
14
80
30
12

553
553
354
1067
635
354
2032
762
305

25
23
16
48
28
16
90b
36
16

635
584
406
1219
712
406
2286
914
406

25
23
16
49
30
18
90b
36
16

635
584
406
1245
762
457
2286
914
406

25
23
16
48
28
16
98b
36
16

635
584
406
1219
712
406
2489
914
406

—
—
—
49
30
18
98b
36
16

—
—
—
1245
762
457
2489
914
406

Class 8640—Part Winding
Enclosed—NEMA Type 1 / 4 / 12

NEMA
Size

1PW
or
2PW

3PW

4PW

Class 8640
Part Winding
5PW

6PW
a
b

Open

Dim.

H
W
D
H
W
D
H
W
D
H
W
D
H
W
D

Non-Combo

Combo with Circuit Breaker

in.

mm

in.

mm

in.

mm

21
21
6
42
26
7
42
26
7
35
22
10
49
24
11

553
553
152
1067
660
178
1067
660
178
889
559
254
1245
610
279

25
23
8
48
28
8
48
28
8
44
24
12
64
28
16

635
584
203
1219
712
203
1219
712
203
1118
610
305
1626
712
406

34
19
11
44
30
12
44
30
12
78ba
36
16
—
—
—

853
483
279
1118
762
305
1118
762
305
1981
914
406
—
—
—

Subtract 8 in. from height for Type 1 or 12 enclosure.
Free standing enclosure.

Combo with Disconnect
Switch
in.
mm
25
23
8
52
25
11
78b
32
16
78ba
36
16
90b
64
24

635
584
203
1321
635
279
1981
813
406
1981
914
406
2286
1626
406

Combination Starter Form Reference
Circuit Breaker: Y791, Y7911
Nonfusible Disconnect Switch: Y792, Y7910
Fusible Disconnect Switch: Y793-Y799
Refer to page 17-32 for a complete listing of Forms for combination devices.

© 2012 Schneider Electric
All Rights Reserved

17-23

17

Table 17.60:

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Note: H = Height, W = Width, D = Depth

Multispeed Magnetic
Starters

Application Data
Class 8810 / Refer to Catalog 8502CT9701

17

Multispeed motors are available in two basic versions:
1) separate winding, and 2) consequent pole. A separate
winding motor has a winding for each speed while a
consequent pole motor has a winding for every two speeds
(three-speed motors have two windings). The motor
connections (and thus the types of controllers) for two
speed starters are exemplified by the schematic diagrams
shown below. Note that consequent pole two-speed
controllers involve a 5-pole and a 3-pole starter, while
separate winding controllers have two 3-pole starters.
Verify the type of motor before ordering. Field
modification of starters to match the motor may not
be possible.
Separate winding motors are usually chosen when
flexibility is important, since the speeds of a consequent
pole motor are usually limited to a 2/1 ratio; a broad range
of speeds can be obtained on a separate winding motor.

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Table 17.65:

Table 17.64:

Typical Applications

Constant HP

Constant Torque

Variable Torque

A. Spindles
B. Cutting Tools
1. Lathes
2. Saws

A. Conveyors
B. Mills
C. Dough Mixers
D. Reciprocating Pumps

A. Fans
B. Centrifugal Pumps

Typical Schematic Diagrams
HIGH 4

1 STOP

LOW

L

5 H

OL OL

HIGH 4

1 STOP

LOW

L
H

L1

L2
L3

L2
L3

L

OL OL OL

HIGH 4

1 STOP

H

H

OL OL
L

H

H

T2 T3

T6

L

OL

L

OL OL

H

H

H

H

L2
L3

H

L

OL OL OL

T2

T3

T6

T4

L
L

OL OL

1 STOP

HIGH 4

L
HIGH
3 L
H

LOW

5 H

L

OL OL

1 STOP

HIGH 4

L
H

2

HIGH
3 L

H

H

ON
L

H

17-24

L

T2 T3

H

H

H

OL OL OL

T11 T12 T13

2-Speed
Separate Winding
Constant HP, Constant Torque
and Variable Torque
NEMA Size 0–4
Sizes 5, 6, & 7 Use Special Circuitry

The stop button must be pressed before it is possible to
change from a higher to a lower speed.
(Not available with Form R1.)
Form R3 Decelerating Relay/Timer. This is similar in
action to Form R2 accelerating relays, except that they
function to prevent immediate transfer from a higher to a
lower speed. A definite time interval, preset on the timer,
must elapse between each speed change.
Form R10 Antiplugging Relays/Timers. This Form
imposes a time delay when transferring from the forward
to the reverse direction or reverse to forward, for
reversing multispeed starters. This provides up to a
60 second delay in the transfer of the direction of the
motor, and can help prevent damage which could result
from plugging.
Form Y81 (Low Speed) Overload Relay Modification.
For NEMA size 3 and 4, when the low speed full load
current does not appear on the appropriate thermal unit
selection tables, include Form Y81 (low speed) (no charge
for this Form). This Form modifies the overload relay block
to accept Type B thermal units. For assistance on thermal
unit selection, contact the Customer Care Center (CCC) at
1-888-778-2733.

Special Pilot Lighting

HIGH 4 LOW 5 H

2

L

OL OL OL

2-Speed
Consequent Pole
Constant or Variable Torque
NEMA Size 0–4
Sizes 5, 6, & 7 Use Special Circuitry

General. Some applications require special relays to
control the speed change and/or starting of the motor.
The descriptions that follow cover the four common relay
schemes for these applications.
Form R1 Compelling Relay. This relay requires the
motor to be started at low speed before any higher speed
can be selected. This arrangement ensures that the motor
will always start the load at low speed. The stop button
must be pressed before it is possible to change from a
higher to a lower speed. (Not available with Form R2.)
Form R2 Accelerating Relay/Timer. With Form R2
accelerating relays, the ultimate speed is determined by
the button which is pressed, but the starter will start the
motor at low speed and automatically accelerate it through
successive steps until the selected speed is reached.
Definite time intervals must elapse between each speed
change. Individual adjustable timing relays are provided
for each interval.

L

H

T5

Additional Features—Special Relays for
Non-Reversing and Reversing Multispeed
Starters

Table 17.66:

HIGH L
3

OLOL

H

L

OL

T1

T5

2-Speed
Consequent Pole
Constant Horsepower
NEMA Size 0–4
Sizes 5, 6, & 7 Use Special Circuitry

L

L1

L

T4

H

5

2

T1
T1

LOW

H

L1

L

OL OL

L

HIGH
3 L

2

H

L

L

5 H

L

HIGH
3 L

2

1 STOP

www.schneider-electric.us

Both separate winding and consequent pole motors are
available in three types: 1) constant horsepower,
2) constant torque, and 3) variable torque. Table 17.64
shows typical applications for these different types of
motors.
NOTE: For detailed information involving the technical
aspects of flexibility of the starters used in the
multispeed controllers, see Classes 8702,
8736, and 8810 application data.

H

2

LOW

5 H

L

L

H

HIGH
3 L

H

H
OFF

1 STOP HIGH 4
OL OL

LOW

L
5 H

L

1 STOP

L
2
L
H

L

HIGH
3 L
H

H

OL OL
HIGH 4

LOW

5 H

L
H
2
ON
OFF

HIGH
3 L

L

OL OL

H
H

H
L

H

OFF

To Power Circuit

To Power Circuit

To Power Circuit

To Power Circuit

To Power Circuit

One pilot light “On”

One pilot light “Off”

Two pilot lights
“L” and “H'”

Two pilot lights
“On” and “Off”

Three pilot lights
“L”, “H”, and “Off”
“L”, “H” and “Off”

© 2012 Schneider Electric
All Rights Reserved

Multispeed Magnetic
Starters

Application Data

Multispeed motors are available in two basic versions: 1) consequent pole, and 2) separate winding. A separate
winding motor has a winding for each speed while a consequent pole motor has a winding for every two speeds
(three-speed motors have two windings).

3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz
Note that the prices shown do not include thermal units. Devices require 6 thermal units (Sizes 0–6). Standard trip
thermal units are $21.50 each. See Digest 176 page 16-116 for selection information.
Table 17.67:

Class 8810—Non-Combination Type
Maximum Polyphase Horsepower Ratings

Type of
Motor

Constant
Horsepower
Motors

NEMA
Size

200 V

Constant
HP

Constant
Torque
or
Variable
Torque

Constant
HP
b

Constant
Torque
or
Variable
Torque
b

Constant
Torque
or
Variable
Torque

Constant
HP
b

Constant
Torque
or
Variable
Torque
b

460–
575 V

200 V

0
1
2
3
4
5
6
0
1
2
3
4
5
6

2
5
7-1/2
20
30
60
100
—
—
—
—
—
—
—

2
5
10
25
40
75
150
—
—
—
—
—
—
—

3
7-1/2
20
40
75
150
300
—
—
—
—
—
—
—

—
—
—
—
—
—
—
3
7-1/2
10
25
40
75
150

0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7

2
5
7-1/2
20
30
60
100
—
—
—
—
—
—
—
—
—

2
5
10
25
40
75
150
225
—
—
—
—
—
—
—
—

3
7-1/2
20
40
75
150
300
450
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
3
7-1/2
10
25
40
75
150
—

Table 17.68:

Constant
HP

230 V

NEMA Type 1
General
Purpose
Enclosure

Constant Torque
or Variable
Torque Motors

230 V

460–
575 V

Type

$ Price

NEMA Type 4 & 4X
Watertight and
Dusttight
Enclosure
(Stainless Steel)
(304)
(Sizes 0—5)
Sheet Steel
(Size 6)
Type

$ Price

Single Winding (Consequent Pole) 5-Pole–3-Pole
—
—
SBG1c
2199. SBW1c
3567.
—
—
SCG1c
2370. SCW1c
3708.
—
—
SDG1c
4307. SDW1c
5958.
—
—
SEG1c
6501. SEW1c
8837.
—
—
SFG1c
17352. SFW1c
22365.
—
—
SGG1c
34286. SGW1c
46008.
—
—
SHG1c
77286. SHW1c
93308.
3
5
SBG2c
2199. SBW2c
3567.
7-1/2
10
SCG2c
2370. SCW2c
3708.
15
25
SDG2c
4307. SDW2c
5958.
30
50
SEG2c
6501. SEW2c
8837.
50
100
SFG2c
17352. SFW2c
22365.
100
200
SGG2c
34286. SGW2c
46008.
200
400
SHG2c
77286. SHW2c
93308.
Two Winding (Separate Winding) 3-Pole–3-Poleb
—
—
SBG3c
1571. SBW3c
2939.
—
—
SCG3c
1772. SCW3c
3110.
—
—
SDG3c
3167. SDW3c
3231.
—
—
SEG3c
4962. SEW3c
7412.
—
—
SFG3c
12168. SFW3c
17181.
—
—
SGG3c
28718. SGW3c
40440.
—
—
SHG3c
58755. SHW3c
66090.
—
—
SJG3c
76032.
—
—
3
5
SBG4c
1571. SBW4c
2939.
7-1/2
10
SCG4c
1772. SCW4c
3110.
15
25
SDG4c
3167. SDW4c
3231.
30
50
SEG4c
4962. SEW4c
7412.
50
100
SFG4c
12168. SFW4c
17181.
100
200
SGG4c
28718. SGW4c
40440.
200
400
SHG4c
58755. SHW4c
66090.
300
600
SJG4c
76032.
—
—

NEMA Type 4Xd
Watertight,
Dusttight
and Corrosion
Resistant
Enclosure

NEMA Type 12/3Rf
Dusttight and
Driptight
Industrial Use
Enclosure

Open Type

Type

$ Price

Type

$ Price

Type

$ Price

SBW51c
SCW51c
SDW51c
—
—
—
—
SBW52c
SCW52c
SDW52c
—
—
—
—

4100.
4278.
6557.
—
—
—
—
4100.
4278.
6557.
—
—
—
—

SBA1c
SCA1c
SDA1c
SEA1c
SFA1c
SGA1c
SHA1c
SBA2c
SCA2c
SDA2c
SEA2c
SFA2c
SGA2c
SHA2c

2640.
2811.
4932.
7925.
20172.
46008.
83753.
2640.
2811.
4932.
7925.
20172.
46008.
83753.

SBO1c
SCO1c
SDO1c
SEO1c
SFO1c
SGO1c
SHO1c
SBO2c
SCO2c
SDO2c
SEO2c
SFO2c
SGO2c
SHO2c

2142.
2285.
4050.
6101.
15786.
31197.
70799.
2142.
2285.
4050.
6101.
15786.
31197.
70799.

SBW53c
SCW53c
SDW53c
—
—
—
—
—
SBW54c
SCW54c
SDW54c
—
—
—
—
—

3384.
3567.
3564.
—
—
—
—
—
3384.
3567.
3564.
—
—
—
—
—

SBA3c
SCA3c
SDA3c
SEA3c
SFA3c
SGA3c
SHA3c
SJA3c
SBA4c
SCA4c
SDA4c
SEA4c
SFA4c
SGA4c
SHA4c
SJA4c

2015.
2213.
2529.
6386.
14988.
40440.
65195.
82826.
2015.
2213.
2529.
6386.
14988.
40440.
65195.
82826.

SBO3c
SCO3c
SDO3c
SEO3c
SFO3c
SGO3c
SHO3c
SJO3c
SBO4c
SCO4c
SDO4c
SEO4c
SFO4c
SGO4c
SHO4c
SJO4c

1515.
1686.
1956.
4590.
11429.
26994.
51848.
69195.
1515.
1686.
1956.
4590.
11429.
26994.
51848.
69195.

Class 8810—Combination Circuit Breaker Type (Thermal Magnetic Circuit Breakers)ae
0
1
2
3
4
5
6
0
1
2
3
4
5
6

2
5
7-1/2
20
30
60
100
—
—
—
—
—
—
—

2
5
10
25
40
75
150
—
—
—
—
—
—
—

0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7

2
5
7-1/2
20
30
60
100
—
—
—
—
—
—
—
—
—

2
5
10
25
40
75
150
225
—
—
—
—
—
—
—
—
a
b
c
d
e
f

© 2012 Schneider Electric
All Rights Reserved

Single Winding (Consequent Pole) 5-Pole–3-Pole
—
—
CBG1c
4206. CBW1c
6429. CBW51c
6962. CBA1c
4676.
—
—
—
CCG1c
4377. CCW1c
6566. CCW51c
7140. CCA1c
4867.
—
—
—
CDG1c
6758. CDW1c
10089. CDW51c
10089. CDA1c
7497.
—
—
—
CEG1c
9162. CEW1c
13836.
—
— CEA1c
10787.
—
—
—
CFG1c
22224. CFW1c
29460.
—
— CFA1c
26753.
—
—
—
CGG1c
43758. CGW1c
57816.
—
— CGA1c
56847.
—
—
—
CHG1c
91229. CHW1c
68843.
—
— CHA1c
65841.
—
5
CBG2c
4206. CBW2c
6429. CBW52c
6962. CBA2c
4676.
—
3
10
CCG2c
4377. CCW2c
6566. CCW52c
7140. CCA2c
4867.
—
7-1/2
15
25
CDG2c
6758. CDW2c
10089. CDW52c
10089. CDA2c
7497.
—
30
50
CEG2c
9162. CEW2c
13836.
—
—
CEA2c
10787.
—
50
100
CFG2c
22224. CFW2c
29460.
—
—
CFA2c
26753.
—
100
200
CGG2c
43758. CGW2c
57816.
—
—
CGA2c
56847.
—
200
400
CHG2c
91229. CHW2c
68843.
—
—
CHA2c
65841.
—
Two Winding (Separate Winding) 3-Pole–3-Poleb
3
—
—
—
CBG3c
3581. CBW3c
5801. CBW53c
6251. CBA3c
4050.
—
7-1/2
—
—
—
CCG3c
3780. CCW3c
5972. CCW53c
6429. CCA3c
4248.
—
20
—
—
—
CDG3c
5616. CDW3c
8379. CDW53c
8879. CDA3c
6357.
—
40
—
—
—
CEG3c
7626. CEW3c
12297.
—
— CEA3c
9248.
—
75
—
—
—
CFG3c
17040. CFW3c
16182.
—
— CFA3c
14379.
—
150
—
—
—
CGG3c
38190. CGW3c
52248.
—
— CGA3c
51278.
—
300
—
—
—
CHG3c
72629. CHW3c
84306.
—
— CHA3c
80199.
—
450
—
—
—
CJG3c
95358.
—
—
—
— CJA3c
103217.
—
3
3
5
CBG4c
3581. CBW4c
5801. CBW54c
6251. CBA4c
4050.
—
—
7-1/2
7-1/2
10
CCG4c
3780. CCW4c
5972. CCW54c
6429. CCA4c
4248.
—
—
10
15
25
CDG4c
5616. CDW4c
8379. CDW54c
8879. CDA4c
6357.
—
—
25
30
50
CEG4c
7626. CEW4c
12297.
—
— CEA4c
9248.
—
—
40
50
100
CFG4c
17040. CFW4c
16182.
—
— CFA4c
14379.
—
—
75
100
200
CGG4c
38190. CGW4c
52248.
—
— CGA4c
51278.
—
—
150
200
400
CHG4c
72629. CHW4c
84306.
—
— CHA4c
80199.
—
—
—
300
600
CJG4c
95358.
—
—
—
— CJA4c
103217.
The NEC 1300% maximum setting for instantaneous trip circuit breakers may be inadequate for multispeed motors.
Prices and type numbers shown for three phase, separate-winding motor starters apply only when motor windings are wye connected.
When motor windings are connected open delta, use the prices shown for three phase consequent pole motor starters.
Voltage code must be specified to order this product. Refer to standard voltage codes shown on page 17-18.
NEMA Type 4X hubs are included with each starter at no additional cost.
Not available in Mag-Gard versions.
NEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications.
See Digest 176 page 16-95 for more information.
3
7-1/2
20
40
75
150
300
—
—
—
—
—
—
—

—
—
—
—
—
—
—
3
7-1/2
10
25
40
75
150

CP1

Discount
Schedule

—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—

17-25

17

www.schneider-electric.us

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Class 8810 / Refer to Catalog 8502CT9701

Multispeed Magnetic
Starters

Two-Speed Combination Starters
Class 8810 / Refer to Catalog 8502CT9701

17

3-Pole Polyphase, 600 Vac Max., 50–60 Hz
Note that the prices shown do not include thermal units.
Devices require 6 thermal units (Sizes 0–6).

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Table 17.69:

Class 8810—Combination Disconnect Switch Type (Class H Fuse Clips)
Maximum Polyphase Horsepower Ratings

Type of
Motor

Constant
Horsepower
Motors

NEMA
Size
200 V

0
1
2
Constant
Horsepower

3
4
5
6
0
1

Constant
Torque
or
Variable
Torque

2
3
4
5
6

0
1
2
Constant
Horsepower
a

3
4
5
6
0
1

Constant
Torque
or
Variable
Torque
a

2
3
4
5
6

230 V

Constant Torque
or Variable
Torque Motors
460–
575 V

200 V

230 V

Fuse
Clip
Size
A

460–
575 V

NEMA Type 4 & 4X
Watertight
and Dusttight Enclosure
Stainless Steel (304)
(Sizes 0–5)
Sheet Steel (Size 6 not 4X)

NEMA Type 1
General
Purpose
Enclosure
Type

$ Price

Type

$ Price

NEMA Type 12/3Rc
Dusttight and
Driptight
Industrial Use
Enclosure
Type

Single Winding (Consequent Pole) 5-Pole–3-Pole
None
UBG1b
3537.00
UBW1b
5759.00
UBA1b
2
2
3
—
—
—
30d
DBG1b
3765.00
DBW1b
5988.00
DBA1b
None
UCG1b
3708.00
UCW1b
5903.00
UCA1b
5
5
7-1/2
—
—
—
30d
DCG1b
3936.00
DCW1b
6129.00
DCA1b
None
UDG1b
6015.00
UDW1b
8751.00
UDA1b
7-1/2
10
20
—
—
—
60
DDG1b
6129.00
DDW1b
8864.00
DDA1b
None
UEG1b
8666.00
UEW1b
13337.00
UEA1b
20
25
40
—
—
—
100
DEG1b
8837.00
DEW1b
13508.00
DEA1b
None
UFG1b
19517.00
UFW1b
27693.00
UFA1b
30
40
75
—
—
—
200
DFG1b
20970.00
DFW1b
25964.00
DFA1b
None
UGG1b
39644.00
UGW1b
35799.00
UGA1b
60
75
150
—
—
—
400
DGG1b
40154.00
DGW1b
54212.00
DGA1b
None
UHG1b
87789.00
UHW1b
99824.00
UHA1b
100
150
300
—
—
—
600
DHG1b
91085.00
DHW1b
103121.00
DHA1b
None
UBG2b
3537.00
UBW2b
5759.00
UBA2b
—
—
—
3
3
5
30d
DBG2b
3765.00
DBW2b
5988.00
DBA2b
None
UCG2b
3708.00
UCW2b
5903.00
UCA2b
—
—
—
7-1/2
7-1/2
10
30d
DCG2b
3936.00
DCW2b
6129.00
DCA2b
UDW2b
8751.00
UDA2b
None
UDG2b
6015.00
—
—
—
10
15
25
DDW2b
8864.00
DDA2b
60
DDG2b
6129.00
None
UEG2b
8666.00
UEW2b
13337.00
UEA2b
—
—
—
25
30
50
100
DEG2b
8837.00
DEW2b
13508.00
DEA2b
None
UFG2b
19517.00
UFW2b
27693.00
UFA2b
—
—
—
40
50
100
200
DFG2b
20970.00
DFW2b
25964.00
DFA2b
None
UGG2b
39644.00
UGW2b
35799.00
UGA2b
—
—
—
75
100
200
400
DGG2b
40154.00
DGW2b
54212.00
DGA2b
None
UHG2b
87789.00
UHW2b
99824.00
UHA2b
—
—
—
150
200
400
600
DHG2b
91085.00
DHW2b
103121.00
DHA2b
Two Winding (Separate Winding) 3-Pole–3-Pole
None
UBG3b
2910.00
UBW3b
5133.00
UBA3b
2
2
3
—
—
—
30d
DBG3b
3140.00
DBW3b
5360.00
DBA3b
None
UCG3b
3110.00
UCW3b
5304.00
UCA3b
5
5
7-1/2
—
—
—
30d
DCG3b
3338.00
DCW3b
5531.00
DCA3b
None
UDG3b
4877.00
UDW3b
7640.00
UDA3b
7-1/2
10
20
—
—
—
60
DDG3b
4991.00
DDW3b
7754.00
DDA3b
None
UEG3b
7127.00
UEW3b
11798.00
UEA3b
20
25
40
—
—
—
100
DEG3b
7866.00
DEW3b
11969.00
DEA3b
None
UFG3b
15159.00
UFW3b
22509.00
UFA3b
30
40
75
—
—
—
200
DFG3b
17324.00
DFW3b
23021.00
DFA3b
None
UGG3b
34073.00
UGW3b
48131.00
UGA3b
60
75
150
—
—
—
400
DGG3b
34586.00
DGW3b
48644.00
DGA3b
None
UHG3b
69188.00
UHW3b
80868.00
UHA3b
100
150
300
—
—
—
600
DHG3b
72485.00
DHW3b
84164.00
DHA3b
None
UBG4b
2910.00
UBW4b
5133.00
UBA4b
—
—
—
3
3
5
30d
DBG4b
3140.00
DBW4b
5360.00
DBA4b
None
UCG4b
3110.00
UCW4b
5304.00
UCA4b
—
—
—
7-1/2
7-1/2
10
30d
DCG4b
3338.00
DCW4b
5531.00
DCA4b
None
UDG4b
4877.00
UDW4b
7640.00
UDA4b
—
—
10
15
25
—
60
DDG4b
4991.00
DDW4b
7754.00
DDA4b
None
UEG4b
7127.00
UEW4b
11798.00
UEA4b
—
—
—
25
30
50
100
DEG4b
7866.00
DEW4b
11969.00
DEA4b
None
UFG4b
15159.00
UFW4b
22509.00
UFA4b
—
—
—
40
50
100
200
DFG4b
17324.00
DFW4b
23021.00
DFA4b
None
UGG4b
34073.00
UGW4b
48131.00
UGA4b
—
—
—
75
100
200
400
DGG4b
34586.00
DGW4b
48644.00
DGA4b
None
UHG4b
69188.00
UHW4b
80868.00
UHA4b
—
—
—
150
200
400
600
DHG4b
72485.00
DHW4b
84164.00
DHA4b
a
Prices and type numbers shown for three phase, separate-winding
Table 17.70: Coil Voltage Codes
motor starters apply only when motor windings are wye connected.
When motor windings are connected open delta, use the prices shown
Voltage
for three phase consequent pole motor starters.
Code
b
Voltage code must be specified to order this product. Refer to standard
60 Hz
50 Hz
voltage codes shown below.
24fe
—
V01
c
NEMA Type 12 enclosures may be field modified for outdoor
120f
110
V02
non-corrosive and non-service entrance rated applications. See
208
—
V08
Digest 176 page 16-95 for more information.
240
220
V03
d
When separate control is specified, use V8x (see page 32) voltage
—
380
V05
codes to specify motor and control voltages.
480
440
V06
600
550
V07
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17-28
Specify
Specify
V99
Refer to the following Digest 176 pages for:
Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-100
Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-105
Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-109

17-26

www.schneider-electric.us

Standard trip thermal units are $21.50 each.
See Digest 176 page 16-116 for selection information.

CP1

Discount
Schedule

$ Price

4008.00
4235.00
4179.00
4406.00
6758.00
6870.00
10287.00
10458.00
24987.00
22500.00
34622.00
52446.00
95324.00
98621.00
4008.00
4235.00
4179.00
4406.00
6758.00
6870.00
10287.00
10458.00
24987.00
22500.00
34622.00
52446.00
95324.00
98621.00
3380.00
3609.00
3581.00
3807.00
5616.00
5732.00
8751.00
9491.00
19803.00
21852.00
50439.00
50952.00
76766.00
80063.00
3380.00
3609.00
3581.00
3807.00
5616.00
5732.00
8751.00
9491.00
19803.00
21852.00
50439.00
50952.00
76766.00
80063.00

$ Price Adder
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
35.60

e

24 V coils are not available on Sizes 4–7. On Sizes 00–3, where 24 V
coils are available, Form S (separate control) must be specified (for
example, order as 8810UBG1V01S).
f
These voltage codes must include Form S (supplied at no charge)
(for example, order as 8810UCG1V02S).
Note: For voltage codes used with control transformers, see page 17-32.
Form S (separate control) is used when a separate source of power is
available for the control (coil) voltage. Form S is supplied at no charge.

© 2012 Schneider Electric
All Rights Reserved

Multispeed Magnetic
Starters

Reversing Two-Speed Magnetic Starters
Class 8810 / Refer to Catalog 8502CT9701

www.schneider-electric.us

Table 17.71:

Class 8810—Reversing
Maximum Polyphase Ratings

Type of
Motor

Constant
Horsepower
Motors

NEMA
Size

Single
Winding
Constant
Horsepower
Single
Winding
Constant
Torque or
Variable
Torque
Two Winding
Constanta
Horsepower
Two Winding
Constanta
Torque
or
Variable
Torque

0
1
2
3
4
5
0
1
2
3
4
5
0
1
2
3
4
5
0
1
2
3
4
5

200 V

230 V

2
5
7-1/2
20
30
60
—
—
—
—
—
—
2
5
7-1/2
20
30
60
—
—
—
—
—
—

2
5
10
25
40
75
—
—
—
—
—
—
2
5
10
25
40
75
—
—
—
—
—
—

Reversing In One Speed Only (Specify High or Low)b
NEMA Type 1
General
Purpose
Enclosure

Constant Torque
or Variable
Torque Motors
460–
575 V
3
7-1/2
20
40
75
150
—
—
—
—
—
—
3
7-1/2
20
40
75
150
—
—
—
—
—
—

200 V

230 V

—
—
—
—
—
—
3
7-1/2
10
25
40
75
—
—
—
—
—
—
3
7-1/2
10
25
40
75

—
—
—
—
—
—
3
7-1/2
15
30
50
100
—
—
—
—
—
—
3
7-1/2
15
30
50
100

460–
575 V
—
—
—
—
—
—
5
10
25
50
100
200
—
—
—
—
—
—
5
10
25
50
100
200

Type
SBG21c
SCG21c
SDG21c
SEG21c
SFG21c
SGG21c
SBG22c
SCG22c
SDG22c
SEG22c
SFG22c
SGG22c
SBG23c
SCG23c
SDG23c
SEG23c
SFG23c
SGG23c
SBG24c
SCG24c
SDG24c
SEG24c
SFG24c
SGG24c

$ Price
3936.
4248.
6984.
10260.
20457.
46449.
3936.
4248.
6984.
10260.
20457.
46449.
3252.
3452.
5817.
9005.
15929.
37335.
3252.
3452.
5817.
9005.
15929.
37335.

NEMA Type 12
Dusttight
and Driptight
Industrial Use
Enclosure

Open
Type

Type

$ Price

Type

SBA21c
SCA21c
SDA21c
SEA21c
SFA21c
SGA21c
SBA22c
SCA22c
SDA22c
SEA22c
SFA22c
SGA22c
SBA23c
SCA23c
SDA23c
SEA23c
SFA23c
SGA23c
SBA24c
SCA24c
SDA24c
SEA24c
SFA24c
SGA24c

5261.
5574.
8522.
13892.
28290.
58172.
5261.
5574.
8522.
13892.
28290.
58172.
4577.
4778.
7353.
12639.
22338.
49058.
4577.
4778.
7353.
12639.
22338.
49058.

SBO21c
SCO21c
SDO21c
SEO21c
SFO21c
SGO21c
SBO22c
SCO22c
SDO22c
SEO22c
SFO22c
SGO22c
SBO23c
SCO23c
SDO23c
SEO23c
SFO23c
SGO23c
SBO24c
SCO24c
SDO24c
SEO24c
SFO24c
SGO24c

Reversing In Both Speeds
NEMA Type 1
General
Purpose
Enclosure

NEMA Type
12/3Rf
Dusttight
and Driptight
Industrial Use
Enclosure

Open
Type

$ Price Type

$ Price Type

$ Price

Type

3851.
4121.
6501.
9662.
19718.
42164.
3851.
4121.
6501.
9662.
19718.
42164.
3167.
3324.
5432.
8267.
15188.
33048.
3167.
3324.
5432.
8267.
15188.
33048.

4563.
4926.
8522.
13508.
26810.
56946.
4563.
4926.
8522.
13508.
26810.
56946.
4193.
4620.
8067.
12027.
21284.
49455.
4193.
4620.
8067.
12027.
21284.
49455.

6330.
6728.
10517.
17139.
33390.
68679.
6330.
6728.
10517.
17139.
33390.
68679.
5958.
6386.
10061.
15885.
27693.
59396.
5958.
6386.
10061.
15885.
27693.
59396.

SBO31c
SCO31c
SDO31c
SEO31c
SFO31c
SGO31c
SBO32c
SCO32c
SDO32c
SEO32c
SFO32c
SGO32c
SBO33c
SCO33c
SDO33c
SEO33c
SFO33c
SGO33c
SBO34c
SCO34c
SDO34c
SEO34c
SFO34c
SGO34c

SBG31c
SCG31c
SDG31c
SEG31c
SFG31c
SGG31c
SBG32c
SCG32c
SDG32c
SEG32c
SFG32c
SGG32c
SBG33c
SCG33c
SDG33c
SEG33c
SFG33c
SGG33c
SBG34c
SCG34c
SDG34c
SEG34c
SFG34c
SGG34c

SBA31c
SCA31c
SDA31c
SEA31c
SFA31c
SGA31c
SBA32c
SCA32c
SDA32c
SEA32c
SFA32c
SGA32c
SBA33c
SCA33c
SDA33c
SEA33c
SFA33c
SGA33c
SBA34c
SCA34c
SDA34c
SEA34c
SFA34c
SGA34c

$ Price
4449.
4791.
8010.
11997.
24930.
52659.
4449.
4791.
8010.
11997.
24930.
52659.
4077.
4449.
7554.
11228.
20487.
43388.
4077.
4449.
7554.
11228.
20487.
43388.

3-Pole Polyphase, 600 Vac Max., 50–60 Hz
Note that the prices shown do not include thermal units. Devices require 6 thermal units (Sizes 0–6). Standard trip
thermal units are $21.50 each. See Digest 176 page 16-116 for selection information.
Table 17.72:
Type
of
Motor

Class 8810—Non-Reversing, Vertically Arranged, Open Type, Two-Speed Starters
Maximum HP Ratings

NEMA
Size

Constant
Horsepower
Constant
Torque
or
Variable
Torque

200 V

0
1
2
3
4
0
1
2
3
4
a
b
c

230 V

380 V

For Consequent Pole Motors
460-575 V

Type

$ Price

For Separate Winding Motors
Type

$ Price

2
2
3
3
SBO11c
2142.00
SBO13c
1515.00
5
5
7-1/2
7-1/2
SCO11c
2282.00
SCO13c
1686.00
7-1/2
10
20
20
SDO11c
4050.00
SDO13c
2939.00
20
25
40
40
SEO11c
6101.00
SEO13c
4563.00
30
40
60
75
SFO11c
15786.00
SFO13c
11429.00
3
3
5
5
SBO12c
2142.00
SBO14c
1515.00
7-1/2
7-1/2
10
10
SCO12c
2282.00
SCO14c
1686.00
10
15
25
25
SDO12c
4050.00
SDO14c
2939.00
25
30
50
50
SEO12c
6101.00
SEO14c
4563.00
40
50
75
100
SFO12c
15786.00
SFO14c
11429.00
Prices and type numbers shown for three phase, separate winding motor starters apply only when motor windings are wye connected. When motor
windings are connected open delta, use the prices shown for consequent pole motor starters.
Specify the speed which requires reversing by adding an L (low) or an H (high) after the type number, e.g., a Class 8810 Type SBG21 with reversing in
low only would be ordered as a Class 8810 Type SBG21L.
Voltage codes must be specified to order this product. Refer to standard voltage codes listed below.

Table 17.73:

Coil Voltage Codes
Voltage

60 Hz

50 Hz

24ed
120e
208
240
—
480
600
Specify

—
110
—
220
380
440
550
Specify

Code
V01
V02
V08
V03
V05
V06
V07
V99

$ Price Adder
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
35.60

d

24 V coils are not available on Sizes 4–7. On Sizes 00–3, where 24 V coils are available,
Form S (separate control) must be specified (for example, order as 8810SCG21V01S).
These voltage codes must include Form S (supplied at no charge) (for example, order as 8810SDG21V02S).
NEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated
applications. See Digest 176 page 16-95 for more information.
Note: For voltage codes used with control transformers, see page 17-18.
Form S (separate control) is used when a separate source of power is available for the control (coil) voltage.
Form S is supplied at no charge.
e
f

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17-28
Refer to the following Digest 176 pages for:
Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . page 16-100
Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . page 16-105
Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . page 16-109

© 2012 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

17-27

17

Note that the prices shown do not include thermal units. Devices require 6 thermal units (Sizes 0–6).
Standard trip thermal units are $21.50 each. See Digest 176 page 16-116 for selection information.

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

3-Pole Polyphase, 600 Vac Max., 50–60 Hz

Multispeed Magnetic
Starters

17

Table 17.74:

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

SBG and SCG

Two-Speed Magnetic Starters
Class 8810 / Refer to Catalog 8502CT9701

NEMA Type 1 Enclosure (see Figure 1)

Type

A
D

A

B

C

D

E

F

G

H

11-7/8

11-7/8

7-17/32

9-3/4

1-1/16

1-1/16

9-3/4

5/16

SDG

14-7/8

14-1/8

7-21/32

12-3/4

1-1/16

1-1/16

12

5/16

SEG3 & 4 and SFG3 & 4

18-5/32

29-5/32

9-15/64

15-1/2

1-11/32

1-11/32

26-1/2

7/16

SEG1 & 2 and SFG1 & 2

22-5/32

39-5/32

10-15/64

19-1/2

1-11/32

1-11/32

36-1/2

7/16

SGG1, 2, 3, 4

20-7/32

65-3/4

16-29/64

31

2-1/8

2-1/8

42

9/16

SHG1, 2, 3, 4

36-7/32

62-7/32

19-15/32

SJG3 & 4

A

B

D

7-13/16

4-1/4

4-3/16 19/32

8-1/4

4-1/4

5-5/16

SEW3 & 4 and SFW3 & 4 18-5/32 32-7/32

8-19/64

12

SEW1 & 2 and SFW1 & 2 22-5/32 42-7/32

9-49/64

SGW1, 2, 3, 4

12-1/8

SBW and SCW

12-5/8 14-11/16
14-7/8

15-3/4

35-7/32 49-7/32

RESET

J

C

SDW

C

Floor Mount

NEMA Type 4 Enclosure (see Figure 1)

Type

E

GB
RESET

Consult Square D

Table 17.75:

www.schneider-electric.us

E

F

Figure 1:
NEMA Type 1, 4, and 12 Enclosures

G

H

I

J

13-1/2

5/16

1-21/32

2-5/16

15

5/16

2-1/32

2-5/8

3-5/64 55/64

30-1/2

7/16

2-37/64

3-3/16

16

3-5/64 55/64

40-1/2

7/16

2-21/64

2-57/64

27

4-3/32 39/64

48

9/16

2-63/64

3-1/2

3/8

I

F
(4) H Dia. Mtg. Holes

A

Table 17.76:
Type

A

B

C

D

E

F

G

11-7/8

13-1/2

7-3/4

4-1/4

3-13/16

3/8

12-3/4

5/16

14-7/8

15-3/4

7-7/8

4-1/4

5-5/16

3/8

15

5/16

SEA3 & 4 and SFA3 & 4

18-5/32

31-1/2

9-19/32

16

3-3/32

1/2

30-1/2

7/16

SEA1 & 2 and SFA1 & 2

22-5/3

41-1/2

10-19/32

16

3-3/32

1/2

40-1/2

7/16

SGA1, 2, 3, 4

35-7/32

49

13-7/64

27

4-7/64

1/2

48

9/16

SHA1, 2, 3, 4

36-7/32

62-7/32

19-15/32

I
H

RESET

RESET

Consult Square D

NEMA
Size

0 and 1
2

B

N
P

L

K

Floor Mount

Fig.
No.

C

H

SDA

Table 17.77:

G

F

SBA and SCA

SJA3 & 4

E

D

NEMA Type 12/3R Enclosure (see Figure 1)

Travel
M

J

Figure 2:
Class 8810 NEMA Sizes 0, 1, and 2

Non-Reversing, Open Type
Mtg.
Holes

A

B

C

D

E

F

G

H

I

J

K

L

M

N

SBO1, 2
SCO1, 2

4

9-5/8

7-11/32

5-5/16

8

5/8

—

7/32

6-29/32

—

7/32

4-3/4

2-1/4

5-1/16

19/32

SBO3, 4
SCO3, 4

3

7-1/8

6-29/32

5-5/16

—

—

3-13/32

15/32

6-7/32

—

7/32

3-9/16

1-5/8

5-1/16

19/32

SDO1, 2

6

12-1/32

8-17/32

6-1/32

10-3/8

1/2

—

1/4

8-1/8

6-1/4

5/32

5-3/4

2-13/16

5-5/32

25/32

SDO3, 4

3

9

8-1/16

6-1/32

—

—

4-1/2

3/8

7-1/2

—

3/16

4-11/32

2-5/32

5-5/32

25/32

SEO1, 2

4

18

14-7/16

17

12-1/4

1-1/2

11/16

1/2

6-7/16

7-3/8

1-21/32

2-5/32

—

—

—

SEO3, 4

4

12-3/4

12-9/32

11-3/4

10-3/4

1-1/32

1/2

1/2

2-1/2

6-3/4

1-5/32

1-5/32

—

—

—

SFO1, 2

4

18-5/8

15-19/32

17

12-1/4

1-27/32

1-1/2

1-1/8

6-7/16

7-21/32

1-21/32

1-21/32

—

—

—

Type

2

3
3
4

4

SFO3, 4

4

14-1/4

14-19/32

13-1/4

12-1/4

1-27/32

1/2

1/2

2-15/16

7-3/8

1-21/32

1-21/32

—

—

—

SGO1, 2a

4

29-9/32

20-9/32

9-3/8

5-13/32

1-9/32

28

5/8

12-9/16

19

5/8

22-17/32

1/2

2-13/32

6-5/8

5

4

6b

—

7c

SGO3, 4

4

19-9/32

20-9/32

9-3/8

5-13/32

1-9/32

18

5/8

2-5/8

19

5/8

12-17/32

1/2

2-13/32

6-5/8

SHO1, 2a

4

29-17/32

22-7/16

9-17/32

6-31/32

3-13/16

28

3/4

11-5/8

21-3/16

5/8

9-7/8

9/16

3-1/32

9-5/16

4

19-17/32

22-7/16

9-17/32

6-31/32

3-13/16

18

3/4

21-3/16

1-11/16

5/8

9-7/8

9/16

3-1/32

9-5/16

SHO3, 4
SJO3, 4

Consult the Customer Care Center (CCC) at 1-888-778-2733.
a
Consequent pole type starters consist of two 3-pole starters as pictured in Figure 4 and an additional 2-pole shorting contactor (not shown),
all on a common baseplate, horizontally mounted.
b
Current transformers used with Size 1 overload relay blocks.
c
Solid-state overload relays and special current transformers.

A
C

A
F

E

7.00
178

.50
13
E

G

C

.50
13
D

B
I

B

K
RESET

RESET

J
NOTE: Illustrations are intended for
dimensional information only
and may not represent the
actual enclosure. Dimensions
are shown in inches.

17-28

G

H

I

.50 F
Prov. for (4) .31 Dia. Mtg. Screws 13
8

.56
14

Reset
Travel
6.25
159

Figure 3: Class 8810 NEMA Sizes 3 and 4

D

H

M

M
K

M

M

N
J
(4) L Dia. Mtg. Holes

Figure 4: Class 8810 NEMA Size 5 and 6
© 2012 Schneider Electric
All Rights Reserved

Multispeed Magnetic
Starters

Approximate Dimensions
Class 8810 / Refer to Catalog 8502CT9701

www.schneider-electric.us

NEMA
Size

NEMA Type 1 Enclosure, Figure 1
Dimensions (in inches)—see Figure 1

Class

Top & Bottom

Sides

Type
A

B

C

13-7/8

23-1/8

D

E

F

21

G

H

I

J

K

L

M

N

O

W

X

Y

1-1/4

7/8

1/2–3/4–1

1/2–3/4–1

1/2

1–1-1/4

1/2–3/4

1/2

0–1

8810

CBG UBG DBG
CCG UCG DCG

19-9/32

1-7/8

1-7/8

2

8810

CDG UDG DDG

15-5/32 28-29/32 9-9/16 11-5/8 26-1/4 21-13/16

2-3/16

2

4

2-5/8

3a

8810

CEG UEG DEG

22-1/8

42-5/8

2-11/32

2-1/8

4-1/4

2-5/8

1-1/4

3-19/64

2-1/4

7/8

3/4 1–1-1/4–1-1/2 1/2–3/4

1/2

4a

8810

CFG UFG DFG

22-1/8

50-1/8 10-3/16 18-5/8 47-1/2 29-3/16

2-29/32 2-11/16 5-3/8

2-5/8

1-5/16

3-19/64

2-1/4

7/8

3/4

1/2

Table 17.79:

8-1/4 10-5/8

10-1/8 18-5/8

40

29-1/8

3-3/4 2-5/16

1-1/16

3-19/64 2-3/16

1-21/64 3-19/64 2-7/32 1-17/64 29/32

2-1/2

1/2–3/4

NEMA Type 4 Enclosure, Figure 2
Dimensions (in inches)—see Figure 2

NEMA
Size

Class

Type

0–1

8810

CBW UBW DBW
CCW UCW DCW

Top &
Bottom

Bottom

A

B

C

D

E

F

G

H

I

J

K

L

W

X

13-7/8

8-21/64

25-3/16

3-19/64

2-9/16

8-3/4

24

19/32

3-61/64

1-5/8

2-5/16

18-17/32

3/4 Hub

1 Hub
1-1/2 Hub

2

8810

CDW UDW DDW

15-1/8

9-37/64

30-15/16

3-19/64

2-9/16

10

29-3/4

19/32

3-61/64

2

2-5/8

21-11/32

3/4 Hub

3a

8810

CEW UEW DEW

22-1/8

10-1/8

46-1/4

3-19/64

3

16

44

5/8

3-15/16

1-3/4

2-5/8

29-1/8

3/4 Hub

2 Hub

4a

8810

CFW UFW DFW

22-1/8

10-3/16

53-3/4

3-19/64

3

16

51-1/2

5/8

3-15/16

2-9/32

3-3/16

29-3/16

3/4 Hub

2-1/2 Hub

Table 17.80:

NEMA Type 12 Enclosure, Figure 3
Dimensions (in inches)—see Figure 3

NEMA
Size

Class

0–1

8810

Type
A

B

C

D

E

F

G

H

I

J

CBA UBA DBA
CCA UCA DCA

13-7/8

10-3/32

24-3/4

3-19/64

2-9/16

8-3/4

24

3/8

3-61/64

20-9/32
23-7/16

2

8810

CDA UDA DDA

15-5/32

10-31/32

31-1/4

3-19/64

3-5/64

9

30-1/4

1/2

4-53/64

3a

8810

CEA UEA DEA

22-1/8

10-1/8

45

3-19/64

3

16

44

5/8

3-15/16

29-1/8

4a

8810

CFA UFA DFA

22-1/8

10-3/16

52-1/2

3-19/64

3

16

51-1/2

5/8

3-15/16

29-3/16

a

Size 3 (5-Pole–3-Pole) with FA, KA circuit breaker or 100 A disconnect switch.
Size 4 (5-Pole–3-Pole) with KA circuit breaker or 200 A disconnect switch. Size 3 & 4 (3-Pole–3-Pole) enclosures may be smaller.
Consult the Customer Care Center (CCC) at 1-888-778-2733 for additional dimensional information.

HANDLE
SWING
L

A
D

M

HANDLE
SWING

HANDLE
SWING
C

A
F

N

K

D

E

A
F

B

H

D

E

B

H

O
Y

E

B

G C

G C

(4) .31 DIA. MTG.HOLES
8 (for Size 0, 1, & 2)

(4) .31 DIA. MTG.HOLES
8 (for Size 0, 1, & 2)

Y

COVER OPEN 90°

(4) .31 DIA. MTG.HOLES
8
(for Size 0, 1, & 2)

COVER OPEN 90°
F

J

L
X W

W

W
G

J

X
J
I

I

H
I

Figure 1:
NEMA Type 1 Enclosure

K

Figure 2:
NEMA Type 4 Enclosure

Figure 3:
NEMA Type 12 Enclosure

NOTE: Illustrations are intended for dimensional
information only and may not represent the
actual enclosure. Dimensions are shown
in inches.

© 2012 Schneider Electric
All Rights Reserved

17-29

17

Table 17.78:

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Disconnect Switch or Circuit Breaker Type

Lighting Contactors

Panelboard Lighting Contactors, Type PB
Class 8903 / Refer to Catalog 8903CT9701

www.schneider-electric.us

17

General Information

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Panelboard lighting contactors, sometimes called remote
control switches, are designed for use with lighting
panelboards and motor control centers where either panel
or bus mounting is desired. Type PB lighting contactors
can be used in a retrofit or new project without increasing
the panelboard depth. They can be used to directly
replace many inoperative existing switches.
Table 17.81:

Class 8903 Type PB Lighting Contactors

Description

Bus Mount

Panel Mount (Includes Lugs)

Size (A)

Poles

Type

30

2
3

PBM 10Ba
PBM 11Ba

2129.00
2403.00

PBM 10a
PBM 11a

2640.00
2973.00

60

2
3

PBP 10Ba
PBP 11Ba

2237.00
2573.00

PBP 10a
PBP 11a

2762.00
3185.00

75

2
3

PBN 10Ba
PBN 11Ba

2237.00
2573.00

PBN 10a
PBN 11a

2762.00
3185.00

100

2
3

PBQ 10Ba
PBQ 11Ba

2541.00
2978.00

PBQ 10a
PBQ 11a

3119.00
3546.00

150

2
3

PBR 10Ba
PBR 11Ba

3162.00
4055.00

PBR 10a
PBR 11a

3897.00
4787.00

200

2
3

PBV 10Ba
PBV 11Ba

3551.00
4496.00

PBV 10a
PBV 11a

4409.00
5360.00

3909.00
4958.00

PBW 10a
PBW 11a

4964.00
5990.00

Panel Mount

File E78427
CCN NRNT

The features include: mechanically held; compatible with
Square D panelboards; short-circuit ratings to 100 kA;
compact arc suppression; bus or panel mounted; fits in
standard-depth lighting panelboards; easy manual
operation; standard coil clearing contacts; and operates in
any position.

$ Price

2
PBW 10Ba
3
PBW 11Ba
Voltage code must be specified to order this product. Refer to standard
voltage codes listed below.
225

a

Table 17.82:

AC Coil Voltage Codes

Table 17.86:

60 Hz

Voltage Code

120
208
240/277
480

V02
V08
V39
V28

Table 17.83:

Class 8903—Auxiliary Contacts

Type

Description

PBX1
PBX2

X11
X22

Description

$ Price
158.00
314.00

Dimensions (Panel Mount)

240 V

277 V

480 V

#14
#12
#10

550
900
1425

1650
2700
4275

2200
3600
5700

2925
4700
7550

8800
14400
22800

Max. Volts

100,000
22,000
65,000

600
600
240

Table 17.88:

30–100 A
150–225 A

#1/0 Max.
350 MCM Max.

#18–#10
#18–#10

2.25

57 7.38 187 2.25 57

9.25 235

8.31

2.88

73 8.50 216 3.00 76 10.50 267

150–
225

C

E

in. mm in. mm in. mm in. mm in. mm in. mm in. mm

b

A

Dimensions (Bus Mount)
Dimensions

150–
14.50 368 7.50 191 3.88 98
225

B

Maximum Wire Size (AWG)
Control Wire
(Cu Only)

30–
100

A

Class J Fuses
Circuit Breaker—Square D—Type LHL
Circuit Breaker—Square D—Type LHL

Power Wire
(Cu/Al)

30–
11.75 298 7.50 191 3.88 98
100

D

Short Circuit
Protection Device Recommended

Current Range

in.

W

Short-Circuit Ratings

RMS Sym.
Current (A)

Amperes

Amperes

208 V

Table 17.89:

Dimensions
H

Maximum Distance (feet)
120 V

Table 17.87:
243.00
485.00

(1) Auxiliary Contact SPDT
(2) Auxiliary Contacts SPDT

Table 17.85:

Control Distance

Wire Gauge
AWG

Factory Modifications

Form

H

W

D

A

B

mm

in.

mm

in.

mm

in.

mm

in.

mm

211

7.50

191

3.38

86

2.25

57

7.38

187

9.50

241

7.50

191

3.38

86

2.88b

73

8.50

216

Slotted mounting holes suitable for 2.88–3.19 in. mounting centers.

A

A

H

$ Price

$ Price

(1) Auxiliary Contact SPDT
(2) Auxiliary Contacts SPDT

Table 17.84:

Type

A

B
E

B
H

W
C
W

17-30

D

D

CP1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Well-Guard™ Pump Panel

Reduced Voltage Type
Class 8940 / Refer to Catalog 8940CT9701
Coil Voltage Codes

Voltage
60 Hz

Code

50 Hz

$ Price Adder

No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
35.60
24 V coils are not available on Sizes 4–7. On Sizes 2–3, where 24 V
coils are available, Form S (separate control) must be specified.
This voltage code must include Form S (no charge).

24c
120d
208
240
—
480
600
Specify
c
d

—
110
—
220
380
440
550
Specify

V01
V02
V08
V03
V05
V06
V07
V99

Closed Transition Autotransformer Type, 3-Pole Polyphase—480 Vac Maximum (50–60 Hz)

Note: The prices shown do not include thermal units. Overload relays are ambient temperature compensated. Devices require 3 thermal units (Sizes 2–6). Standard trip thermal units are $21.50 each.
Motor
(Starter)
Volts

Max. HP
Polyphase
15
25
30
50
75
100
25
30
50
75
100
150
200
300
400
600

230
(240)

460
(480)

Table 17.92:

Coil
Voltage

Fusible Disconnect Type

NEMA
Size

Fuse Clip
Typeb
Amperesa
2
60
RD4DV03
100
RE4FV03
3
200
RE1GV03
240@ 60 Hz
220@ 50 Hz
4
200
RF4JV03
400
RG1LV03
5
400
RG1MV03
2
60
RD2FV06
100
RE2GV06
3
100
RE2JV06
200
RF2LV06
4
200
RF2MV06
480 @ 60 Hz
440 @ 50 Hz
400
RG3PV06
5
400
RG3QV06
—
—
6
—
—
7
—
—
a
Fuse clips are sized for use with dual-element time-delay fuses.

Circuit Breaker Type
$ Price Circuit Breaker

Typeb

$ Price

11928.00
FAL36080
VD1DV03
11928.00
17055.00
FAL36100
VE1FV03
17055.00
17342.00
KAL36100
VE2GV03
17342.00
26657.00
KAL36200
VF1JV03
28107.00
43946.00
LAL36250
VG2LV03
43946.00
46083.00
LAL36350
VG2MV03
46083.00
12555.00
FAL36070
VD1FV06
12555.00
17085.00
FAL36080
VE1GV06
17085.00
18197.00
FAL36100
VE1JV06
18197.00
26657.00
KAL36125
VF1LV06
27872.00
28278.00
KAL36200
VF1MV06
28278.00
42735.00
LAL36250
VG4PV06
46340.00
48860.00
LAL36350
VG4QV06
51237.00
—
MAL36600
VH1SV06
79338.00
—
MAL36900
VH2TV06
79338.00
—
MAL361000
VJ1WV06
123134.00
b
Coil voltage code must be specified to order this product. Refer to
standard voltage codes shown in Table 17.90.

Part Winding Type, 3-Pole Polyphase—480 Vac Maximum (50–60 Hz)

Note: The prices shown do not include thermal units. Overload relays are ambient temperature compensated. Devices require 6 thermal units (Sizes 2–6). Standard trip thermal units are $21.50 each.
Motor
(Starter)
Voltage

Combination Fusible Disconnect Type
Max. HP
Polyphase

230
(240)

460
(480)

25
30
50
75
100
125
150
30
40
60
75
100
150
200
250
350

Coil
Voltage

NEMA
Size

Fuse Clip
(2 Sets)
Typed
(A)c
2PW
60
MD4FV03
60
ME5GV03
3PW
100
ME6JV03
240 @ 60 Hz
4PW
200
MF1LV03
220 @ 50 Hz
200
MG3MV03
5PW
400
MG1NV03
400
MG1PV03
30
MD5GV06
2PW
60
MD2HV06
60
ME7KV06
3PW
100
ME3LV06
480 @ 60 Hz
200
MF3MV06
440 @ 50 Hz
4PW
200
MF3PV06
200
MG4QV06
200
MG4RV06
5PW
400
MG2TV06
c
Fuse clips are sized for use with dual-element time-delay fuses.

Table 17.93:

Part Winding—Reduced Voltage Type

Type

Figure

PD
MD
PE, PF
ME
MF
PG, MG
PH

3
3
3
3
4
4
4

Table 17.94:
Type

A
in.
19.00
23.00
30.00
25.00
36.00
36.00
38.00

B
mm
483
584
762
635
914
914
965

in.
34.50
25.50
47.00
52.50
93.00
73.00
93.00

C
mm
876
648
1194
1334
2362
1854
2362

in.
12.25
10.60
13.25
12.13
19.25
19.25
19.25

D
mm
311
269
337
308
489
489
489

in.
13.00
17.00
22.00
19.00
33.75
33.75
35.75

E
mm
330
432
559
483
857
857
908

in.
33.50
24.50
46.00
51.50
12.50
12.50
12.50

F
mm
851
622
1168
1308
318
318
318

in.
0.44
0.44
0.56
0.44
0.69
0.69
0.69

mm
11
11
14
11
18
18
18

Autotransformer—Reduced Voltage Type
Figure

RD, VD
3
RE, VE, RF, VF
4
RG
4
VG
4
VH
4
VJa
4
a
Cabinet has double doors.

© 2012 Schneider Electric
All Rights Reserved

Combination Circuit Breaker Type

Circuit Breaker
$ Price
(2 Bkrs.)
Typed
$ Price
Frame Size
7536.00
FAL36070
PD1FV03
7923.00
11609.00
FAL36080
PE3GV03
11322.00
11609.00
FAL36100
PE3JV03
11322.00
21821.00
KAL36150
PF3LV03
23400.00
43326.00
KAL36175
PG2MV03
43326.00
43326.00
LAL36250
PG3NV03
43326.00
43326.00
LAL36250
PG3PV03
43326.00
7536.00
FAL36040
PD1GV06
7293.00
7536.00
FAL36050
PD1HV06
7293.00
11609.00
FAL36070
PE3KV06
12822.00
11609.00
FAL36090
PE3LV06
11322.00
23400.00
FAL36100
PF2MV06
23400.00
23400.00
KAL36125
PF3PV06
23400.00
PG2QV06
43326.00
43326.00
KAL36175
43326.00
KAL36225
PG3RV06
43326.00
43326.00
LAL36300
PG3TV06
43326.00
d
Coil voltage code must be specified to order this product. Refer to
standard voltage codes shown in Table 17.90.

A
in.
25.00
32.00
36.00
32.00
34.00
64.00

B
mm
635
813
914
813
864
1626

CP1

in.
52.50
72.50
93.00
72.50
93.00
93.00

Discount
Schedule

C
mm
1334
1842
2362
1842
2362
2362

in.
11.13
19.25
19.25
19.25
23.25
27.25
NOTE:

D

E

F

mm
in.
mm
in.
mm
in.
mm
283
19.00
483
51.50
1308
0.44
11
489
29.75
756
12.50
318
0.68
17
489
33.75
857
12.50
318
0.69
17
489
29.75
756
12.50
318
0.68
17
591
31.75
806
16.50
419
0.69
17
692
61.75
1568
17.25
438
0.81
21
Illustrations may not represent the actual enclosure; they are
intended for dimensional information only.

17-31

NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Type VG4V06K15

Table 17.91:

Table 17.90:

Class 8940 reduced voltage panels in NEMA 3R
enclosures are specifically designed for pumping
applications. Extra space is provided for field installation of
auxiliary equipment.
• Type S contactors/starters provided as standard
• All devices are UL Listed, and marked “SUITABLE
ONLY FOR USE AS SERVICE EQUIPMENT”
• Price includes Hand-Off-Auto selector switch and Start
push button
For How to Order Information, see Digest 176 page 16-12
and Digest 176 page 16-125 for selection information.

17

www.schneider-electric.us

Factory Modifications
(Forms)

17

Table 17.95:

Reduced Voltage Starters
Classs 8606, 8630, 8640

www.schneider-electric.us

Reduced Voltage Controllers Only
Classes 8606, 8630, 8640

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

NEMA Size
Factory Modifications

Enclosure
Type

Form

1, 4, 12

A

1
1PW
1 YD

2
2 PW
2 YD

3
3 PW
3 YD

336.00

336.00

336.00

4
4 PW
4 YD

5
5 PW
5 YD

6
6 PW
6 YD

7
7 PW
7 YD

336.00

336.00

336.00

Push Buttonsa
Start-Stop

33600

Selector Switches
Hand-Off-Auto

1, 4, 12

C

336.00

336.00

336.00

336.00

336.00

336.00

336.00

On-Off

1, 4, 12

C6

336.00

336.00

336.00

336.00

336.00

336.00

336.00

1, 4, 12

P

336.00

336.00

336.00

336.00

336.00

336.00

336.00

Pilot Lights (specify color)b
One light On
Separate Control Circuitde
TR coil only (at control voltage)

1, 4, 12

S

N/C

N/C

N/C

N/C

N/C

N/C

N/C

All coils (at control voltage)

1, 4, 12

Y195

N/C

N/C

N/C

N/C

N/C

N/C

N/C

Fused Control Circuitcdef
Pilot Devices in Cover and
Control Circuit
Reduced Voltage
Controllers Only
Classes
8606
8630
8640
8647
8650

One fuse

1, 4, 12

F

314.00

314.00

314.00

314.00

314.00

N/Ch

N/Ch

Two fuses

1, 4, 12

F4

314.00

314.00

314.00

314.00

314.00

N/Ch

N/Ch

Control Circuit Transformercde
Standard Capacity (50 or 60 Hz)
Fuses
Primary

Secondary

2—

0—

1, 4, 12

F4T

684.00

882.00

1112.00

1254.00

1395.00

N/Ch

N/Ch

2..

1—

1, 4, 12

FF4T

1026.00

1197.00

1425.00

1566.00

1710.00

314.00

314.00

2—

0—

1, 4, 12

F4T40

912.00

1182.00

1938.00

2079.00

3803.00

3803.00

3803.00

2—

1—

1, 4, 12

FF4T40

1224.00

1497.00

2250.00

2393.00

4116.00

4116.00

4116.00

100 VA additional capacity

1, 4, 12

T11

300.00

300.00

300.00

300.00

300.00

300.00

300.00

200 VA additional capacity

1, 4, 12

T12

570.00

570.00

570.00

570.00

570.00

570.00

570.00

300 VA additional capacity

1, 4, 12

T13

1139.00

1139.00

1139.00

1139.00

1139.00

1139.00

1139.00

400 VA additional capacity

1, 4, 12

T14

2421.00

2421.00

2421.00

2421.00

2421.00

2421.00

2421.00

500 VA additional capacity

1, 4, 12

T15

2721.00

2721.00

2721.00

2721.00

2721.00

2721.00

2721.00

Additional capacity (50 or 60 Hz)g

Substitute nonstandard single primary and/or single secondary
a
b
c
d
e
f
g
h
i

Voltage rating on the control transformerc
1, 4, 12
T1i
71.00
71.00
71.00
71.00
71.00
—
—
All push buttons are momentary contact.
For pilot light details, refer to the pilot light table in Digest 176 page 16-100.
See Table 17.96 below.
As standard, Reduced Voltage Controllers are supplied with common control. If Form S or T is specified, only the TR coil will be at control voltage.
Specify Form Y195 or T40 (Ex. Form F4T40) if all coils must be at control voltage. Refer to page 17-18 for control circuit arrangements.
Reduced Voltage Controllers are supplied with two control circuit fuses for conductors at line voltage. Additional fusing may be supplied if a fused control
circuit transformer or separate control is specified.
Must be used with Form specifying separate control (Ex. Form FS).
Add Form letters and price to that of standard control transformer. (Example: For Size 1, Form F4T, plus 100 VA becomes F4T11, $984.00
Form F4T40 plus 100 VA becomes F4T41, $807.00).
Size 6 and 7 controllers come with Form F4T as standard.
Must be used in conjunction with a variation of Form of F4T. (Ex. Standard capacity transformer required, 208–24 V. Order as Form F4TT1, 208–24 V.)

Table 17.96:

Selection of Control Circuit Transformers

Voltage
60 Hz (Primary–Secondary)

Code

120–12
120–24
208–120
240–24
240–120
277–120
480–24
480–120
480–240
600–120
Specify

V88
V89
V84
V82
V80
V85
V83
V81
V87
V86
V99

The standard primary and secondary voltages for control circuit transformers are indicated in Table 17.96.
To order, select the desired device with the appropriate transformer Form designation. Then convert the previously
selected voltage code (V••) to reflect the desired primary/secondary voltage for the transformer. The secondary voltage
should equal the previously selected coil voltage of the device. (24 Vac coils for NEMA Sizes 4–7 are not available).

Example:
You previously selected a Class 8606SDG1V02S. The designation V02S means that you need a coil voltage of
120-60/110-50 wired for separate control. You would like to add Form FF4T with the transformer voltages being 480
volt primary, 120 volt secondary. The new, complete Class, Type, Voltage Code, and Form are:

j

17-32

Class

Type

Voltage Code

Formj

8606

SDG1

V81

FF4T

Form numbers should always be shown in alphabetical order.

CP1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Factory Modifications
(Forms)

Reduced Voltage Starters
Class 8606, 8630

www.schneider-electric.us

Class 8606 Reduced Voltage Starters Only

Molded case thermal magnetic circuit breaker b

Nonfusible disconnect switch

Atuomatic molded case switch

NEMA Size

Enclosure
Type

Form

5

6

7

1
4
12
1
4
12
1
4
12

Y791
Y791
Y791
Y792
Y792
Y792
Y7910
Y7910
Y7910

2010.00
2862.00
2037.00
1340.00
2195.00
1368.00
—
—
—

2451.00
3533.00
2564.00
1710.00
2793.00
1823.00
—
—
—

2664.00
4886.00
2862.00
2165.00
4388.00
2366.00
—
—
—

4872.00
7092.00
6579.00
2991.00
5327.00
4815.00
—
—
—

9471.00
11808.00
10839.00
5355.00
7691.00
5925.00
—
—
—

13944.00
18216.00
15012.00
—
—
—
12293.00
16565.00
13361.00

18320.00
23601.00
20397.00
—
—
—
13004.00
17276.00
14072.00

1
4
12
1
4
12
1
4
12
1
4
12
1
4
12
1
4
12
1
4
12

Y793
Y793
Y793
Y794
Y794
Y794
Y795
Y795
Y795
Y796
Y796
Y796
Y797
Y797
Y797
Y798
Y798
Y798
Y799
Y799
Y799

1566.00
2421.00
1596.00
1566.00
2421.00
1596.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

1566.00
2124.00
1596.00
1823.00
2885.00
1938.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
2066.00
3609.00
2280.00
2336.00
4559.00
2537.00
2885.00
5129.00
3105.00
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
2574.00
5021.00
2943.00
3596.00
4340.00
5327.00
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
5868.00
8190.00
6438.00
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
11039.00
15354.00
12861.00
13802.00
18075.00
14871.00
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
15425.00
19697.00
17562.00

1 YD

2 YD

3 YD

1

2

3

4

Fusible Disconnect Switch with Fuse Clips a
30 A clips

Circuit
Breaker
or
Disconnect
Switch

60 A clips

100 A clips

200 A clips

400 A clips

Automatic Molded Case Switch
with 600 A fuse clips
Automatic Molded Case Switch
with fuse clips 1200 A or less
a
b

Fuses not included.
Mag-Gard™ circuit breakers are not supplied nor recommended.

Table 17.98:

Class 8630 Reduced Voltage Controllers Onlyd
Factory Modifications

Molded case thermal magnetic circuit breaker e

Nonfusible disconnect switch

Atuomatic molded case switch

NEMA Size

Enclosure
Type

Form

4 YD

5 YD

6 YD

7 YD

1
4
12
1
4
12
1
4
12

Y791
Y791
Y791
Y792
Y792
Y792
Y7910
Y7910
Y7910

2451.00
3533.00
2564.00
1710.00
2793.00
1823.00
—
—
—

2664.00
4886.00
2856.00
2165.00
4388.00
2366.00
—
—
—

4872.00
7092.00
6579.00
2991.00
5327.00
4815.00
—
—
—

9471.00
11808.00
10839.00
5355.00
7691.00
5925.00
—
—
—

13944.00
18216.00
15012.00
—
—
—
12293.00
16565.00
13361.00

18320.00
23601.00
20397.00
—
—
—
13004.00
17276.00
14072.00

32759.00
37031.00
33827.00
—
—
—
29483.00
33755.00
30551.00

1
4
12
1
4
12
1
4
12
1
4
12
1
4
12
1
4
12
1
4
12

Y793
Y793
Y793
Y794
Y794
Y794
Y795
Y795
Y795
Y796
Y796
Y796
Y797
Y797
Y797
Y798
Y798
Y798
Y799
Y799
Y799

1823.00
2421.00
1938.00
1823.00
2421.00
1938.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

1823.00
3771.00
1938.00
2066.00
3609.00
2280.00
2336.00
4559.00
2537.00
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
2574.00
5021.00
2943.00
2885.00
5129.00
3105.00
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
3596.00
5840.00
5327.00
6510.00
8204.00
6438.00
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
11039.00
15354.00
12861.00
13802.00
18075.00
14871.00
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
14513.00
18786.00
15227.00
15425.00
19697.00
17562.00

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
30195.00
34704.00
31095.00

Fusible Disconnect Switch with Fuse Clipsc
30 A clips

Circuit
Breaker
or
Disconnect
Switch

60 A clips

100 A clips

200 A clips

400 A clips

Automatic Molded Case Switch
with 600 A fuse clips
Automatic Molded Case Switch
with fuse clips 1200 A or less
c
d
e

Fuses not included.
Wye-Delta motor starters typically have higher current ratings per NEMA Size than full voltage motor starters. Care must be taken in selecting the appropriate short circuit protection.
The table on Digest 176 page 7-33 will assist in selecting proper protection based on motor full-load current.
Mag-Gard™ circuit breakers are not supplied nor recommended.

© 2012 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

17-33

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Factory Modifications

17

Table 17.97:

Factory Modifications
(Forms)

Reduced Voltage Starters
Class 8640, 8606, 8630

www.schneider-electric.us

17

NOTE: To comply with Section 430-3 of the National Electrical Code®, combination part-winding starters are
provided as follows:
1.

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

2.
3.

Table 17.99:

Circuit breaker: two thermal-magnetic, adjustable-trip circuit breakers—one for each motor winding. In the smaller controllers that
use the FA and KA frames, a single external operating mechanism operates the two circuit breakers simultaneously. In the larger
controllers that use the KA and LA frames, each circuit breaker has its own operating mechanism.
Nonfusible disconnect switch: a single 3-pole unfused disconnect switch of the proper rating for both windings. The user must
provide proper short-circuit protection external to the starter, using only Class J fuses.
Fusible disconnect switch: a single unfused disconnect switch with two sets of fuse clips (each set of the rating indicated) to provide
short-circuit protection for each winding.

Class 8640 Reduced Voltage Starters Only
Factory Modifications

Molded case thermal magnetic circuit breaker b

NEMA Size

Enclosure
Type

Form

1

Y7911

3014.00

3675.00

3996.00

7307.00

14207.00

—

4

Y7911

4293.00

5300.00

7329.00

10641.00

17711.00

—

12

Y7911

3056.00

3846.00

4293.00

9872.00

16259.00

—

1

Y7931

2006.00

2006.00

—

—

—

—

4

Y7931

2664.00

2664.00

—

—

—

—

12

Y7931

2132.00

2132.00

—

—

—

—

1

Y7941

—

2273.00

2570.00

—

—

—

4

Y7941

—

3969.00

5013.00

—

—

—

12

Y7941

—

2507.00

2790.00

—

—

—

1

Y7951

—

2570.00

2831.00

3176.00

—

—

4

Y7951

—

5013.00

5525.00

5642.00

—

—

12

Y7951

—

2790.00

3239.00

3416.00

—

—

1

Y7961

—

—

3176.00

3959.00

6456.00

—

4

Y7961

—

—

5642.00

6425.00

9026.00

—

12

Y7961

—

—

3416.00

5859.00

7082.00

1

Y7971

—

—

—

6456.00

1 PW

2 PW

3 PW

4 PW

5 PW

6 PW

Fusible Disconnect Switch with Fuse Clips a

30 A clips (two sets)

60 A clips (two sets)

Circuit
Breaker
or
Disconnect
Switch

100 A clips (two sets)

200 A clips (two sets)

400 A clips (two sets)

Automatic molded case switch
with 600 A fuse clips (two sets)

Automatic molded case switch
with fuse clips 601–1200 A or less (two sets)
a
b
c

—

15182.00 c

15596.00 c

4

Y7971

—

—

—

9026.00

19881.00 c

20082.00 c

12

Y7971

—

—

—

7082.00

16356.00 c

16592.00 c

1

Y7920

—

—

—

—

—

15965.00

4

Y7920

—

—

—

—

—

20664.00

12

Y7920

—

—

—

—

—

16748.00

1

Y7921

—

—

—

—

—

16968.00

4

Y7921

—

—

—

—

—

21668.00

12

Y7921

—

—

—

—

—

19319.00

Fuses not included.
Mag-Gard™ circuit breakers are not supplied nor recommended.
Consists of automatic molded case switch with two sets of 400 A fuse clips.

Table 17.100: Reduced Voltage Controllers Onlyc
Classes 8606, 8630, 8640
NEMA Size
Factory Modifications

Non-Compensated Bimetallic Overload Relays
Three Element
Types SC-SD (Sizes 1 & 2)
Types SE-SG (Sizes 3–5)
Type SH (Size 6)

Overload
Relays

Ambient Compensated Bimetallic Overload Relays
Three Element
Types SC-SD (Sizes 1 & 2)
Types SE-SF (Sizes 3 & 4)
Types SG-SH (Sizes 5–6)
Overload Relays General
Substitute 9999SO4 isolated alarm contact on melting alloy overload relay
Substitute 9999SO5 isolated alarm contact on melting alloy overload relay
Motor Logic™ Overload Relaysde

Miscellaneous

a
b
c
d
e

17-34

Add for thermal protector Class 8606
Coil transient suppressor per coil
Addition of terminal blocks (specify wired or unwired).
Wired, per terminal, each
Unwired, per terminal, each

Enclosure
Type

Form

Any
Any
Any

B2
B5
B2

57.00
—
—

57.00
—
—

—
57.00
—

—
57.00
—

—
57.00
—

—
—
57.00

—
—
— b

1, 4, 12
Any
Any

B
Y59
B

86.00
—
—

86.00
—
—

—
107.00
—

—
107.00
—

—
—
86.00

—
—
86.00

—
—
— b

Any
Any

Y342
Y344

179.00
179.00

179.00
179.00

179.00
179.00

179.00
179.00

179.00
179.00

179.00
179.00

— b
— b

Any
Any

H10
H20

122.00
122.00

122.00
122.00

122.00
122.00

122.00
122.00

122.00
122.00

57.00
57.00

57.00
57.00

1, 4, 12
Any

Y116
Y145

—
158.00

570.00
158.00

570.00
158.00

570.00
158.00

570.00
158.00

570.00
—

—
—

1, 4, 12
1, 4, 12

G56a
G50a

116.00
57.00

116.00
57.00

116.00
57.00

116.00
57.00

116.00
57.00

116.00
57.00

116.00
57.00

1
1PW
1 YD

2
2 PW
2 YD

3
3 PW
3 YD

4
4 PW
4 YD

5
5 PW
5 YD

6
6 PW
6 YD

7
7 PW
7 YD

Addition of terminal block 9080CA or 9080GR6 only. The number of circuits is the same as the ending of the Form number. (Example: G505 is 5 wire terminal block.) Available in groups
of 5 only. Order in increments of 5. The number of circuits is the same as the ending of the Form number. (Example: G505 = 5 unwired terminals, G510 is 10 unwired terminals.)
Size 7 uses a solid-state overload relay. See Class 8536 for complete details.
NEMA Type 7 and 9 enclosures not available with Class 8600 devices.
Motor Logic overload relays are not available on Class 8640 Size 1PW to 4PW starters.
See Motor Logic overload relays in the Full Voltage section on the bottom of Digest 176 page 16-83 for additional Form options of Motor Logic overload relays.

CP1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Definite Purpose
Contactors

Reversing/Hoist, Type R

Class 8965 reversing hoist contactors meet the small
space requirements found in electrical hoists, light duty
cranes, door operators, and related products. They are
designed to perform in the short periods of jogging

experienced in hoist service. Note that these contactors
must be mounted upright on the vertical plane; the
contactors will not operate properly when mounted in any
other position.

Table 17.101: AC Reversing/Hoist Contactors—600 Vac Maximum
Horsepower Ratings

No. of
Poles

Type RO10V02

115 V
1Ø

230 V
1Ø

230 V
3Ø

Power
Terminals

460/575 V
3Ø

Witha
Jumper Straps

Withouta
Jumper Straps

Open Type

Open Type

$ Price

Quick Connect
RO10c
RO11c
3-Pole
1
1-1/2
3
3
Polyphase
Pressure Wireb
RO12c
RO13c
a
Jumper straps connect the line side power terminals of the same phase between the forward (up) and reverse (down) contactors in common;
i.e., L1 to L1, L2 to L2, and L3 to L3.
b
Coils rated 120 Vac or less are supplied with quick connect terminals only.
c
Voltage code must be specified to order this product. Refer to standard voltage codes shown in Table 17.105.

998.00

Table 17.102: Miscellaneous Hoist Contactor Kits For Use With Class 8965
Type
Series
Description
RO10
Armature Kit
RO11
A&B
Contact
RO12
Carrier
RO13
d
CP10 discount schedule.
e
One armature per kit.

Class
9998

Type
RP1e

Series

Description
Armature Kit

C

Contact
Carrier

Order as Part Number
3100206050

Class
9998

Type
RP2e

$ Priced
29.40

Order as Part Number
3100208150

39.40

Table 17.103: Class 8965 Replacement Contact Kits
Device
Type

Device
Series

Class 9998
Kit Type

Device
Series

Class 9998
Kit Type

RO10

RA10

RA14

RO11

RA11

RA15

A&B

RO12

C

RA12

RO13

RA16

RA13

RA17

Terminals

1 N.O.
Each Side

Quick Connect
Screw
Quick Connect
Screw

1 N.C.
Each Side

Class 9999
Type
R10
R12
R11
R13

236.00
B
F

$ Price
E

Replacement
Part Number
3100240319g
3100240340g
3100240047h
3100240049h
3100240058hi
3100240060h

D

50.00

A

Table 17.106: Approximate Dimensions
(3 Poles per Contactor)

Table 17.105: Coil Table
Voltage
Voltage
Voltage
60 Hz
50 Hz
Code
24
—
V01
120
110
V02
208/220
—
V21
240
220
V03
480
440
V06
600
550
V07
f
CP10 Discount Schedule.
g
Tape wound coils, 2 per package.
h
Molded coil, 1 per package.
i
Suitable for 440 V 50 Hz applications.

G

202.00

Table 17.104: Auxiliary Contacts Separate Module
Description

C

Provisions for
(3) #8 Mounting Screws

$ Price

$ Pricef
119.00
119.00
114.00
114.00
114.00
83.00

Type

A

B

C

D

E

F

G

RO10, 11

3.31
84

3.31
84

3.03
77

2.69
68

1.34
34

1.56
40

2.66
68

RO12, 13

3.31
84

3.69
94

2.69
68

2.69
68

1.34
34

1.56
40

2.66
68

Table 17.107: Cross Reference—Obsolete Devices
Obsolete
Device
Class
8702
or
8965

8965

Type
HO3
HO4
HO5
HO6
HO7
HO8
RG2S1
RG5S1
RG5S2
RO1
RO1S1
RO1S2
RO1S3
RO1S4
RO1S5
RO1S6

Replacement
Device
Class

Auxiliary Contact
Required

Type
RO12
RO12
RO12
RO12
RO12
RO12
RO10
RO12
RO12
RO10
RO11
RO10
RO11
RO10
RO10
RO10

8965

8965

Class
—
9999
9999
—
9999
9999
9999
9999
9999
—
—
—
—
—
—
—

Burden

Type
—
R12
R13
—
R12
R13
R10
R12
R12
—
—
—
—
—
—
—

Class

Type

8965

RO2
RO2S1
RO2S2
RO3
RO3S1
RO3S2
RO3S3
RO4
RO4S1
RO5
RO5S1
RO5S2
RO6
RO6S1
RO6S2

Replacement
Device

Auxiliary Contact
Required

Class

Type

Class

Type

8965

RO10
RO11
RO10
RO10
RO11
RO10
RO10
RO12
RO13
RO12
RO13
RO12
RO12
RO13
RO12

9999
9999
9999
9999
9999
9999
9999
—
—
9999
9999
9999
9999
9999
9999

R10
R10
R10
R11
R11
R11
R11
—
—
R12
R12
R12
R13
R13
R13

Table 17.108: How to Order

Application Data
Coils

Obsolete
Device

Duty: Hoist Duty—H4 Intermittent
Voltage Range: AC coils only; +10%, –15% of nominal
Inrush 76 VA, Sealed 27 VA

To Order Specify:

•
•
•

Class Number
Type Number
Voltage and Frequency

Catalog Number
Class

Type

Voltage and
Frequency

8695

RO10

V02

Approvals
UL Component Recognized: File E78351, CCN NLDX2
CSA Certified: File LR60905, Class 3211 04
© 2012 Schneider Electric
All Rights Reserved

CP1

CP10

Discount
Schedule

17-35

17

www.schneider-electric.us

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

Class 8965 / Refer to Catalog 8910CT9301

Thermal Overload
Relays—NEMA Style

Solid-State Overload Relay, Motor Logic™ Plus
Class 9065 / Refer to Catalog 9065CT9701

17

Motor Logic Plus—Class 9065

NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS

The Motor Logic Plus solid-state overload relay is
separately powered and fully programmable. It is designed
to protect 3-phase AC motor applications, 200–480 Vac or
600 Vac. The SSOLR has one Form C relay output rated
for 300 Vac maximum.
Motor Logic Plus

Lug-Lug Kit
This kit can be field installed on separately mounted
Motor Logic Plus overload relays.
Table 17.111: Lug-Lug Kit
For Use With

Table 17.109: Motor Logic Plus
Class 9065 SP Solid-State Overload Relay

$ Price
200 to 480 V
600 V
Current Range
SPB4
SPB6
0.5–2.3 A
SPC4
SPC6
2.0–9.0 A
SP14
SP16
6.0–27.0 A
SP24
SP26
10.0–45.0 A
957.00
SP34
SP36
20.0–90.0 A
SP44j
SP46j
60.0–135.0 A
SP54k
SP56k
120.0–270.0 A
SP64l
SP66l
240.0–540.0 A
j
Must use 150:5 external current transformer, purchased separately.
k
Must use 300:5 external current transformer, purchased separately.
l
Must use 600:5 external current transformer, purchased separately.

Class & Type

NEMA Size

8536 SA-SH

1–6

9065 SP

1–6

Parts Kit
Description

Class 9999
Type

$ Price

Lug-Lug Kit

MLPL

80.00

Software Kit
Solutions software program allows an IBM PC compatible
computer (with Windows 95 or greater) to communicate
with a Motor Logic Plus overload relay connected to an
RS-485 network using Modbus protocol.
Table 17.112: Software Kit

Table 17.110: Forms for factory addition to 8536
Open Style only

For Use With

Alpha Character
B

Motor Logic Plus Overload Relay

Class & Type

First Digit
2
3
4
5
6
7
8
9

Current Ranges
0.5–2.3 A
2.0–9.0 A
6.0–27.0 A
10.0–45.0 A
20.0–90.0 A
60.0–135.0 A
120.0–270.0 A
240.0–540.0 A

8536 SA–SH

Second Digit
0
2
4
6

www.schneider-electric.us

NEMA Size

Parts Kit
Description

Class 9999
Type

1–6

Software Kit

MLPS

9065 SP

$ Price

1295.00

Communication Module
This module allows the Motor Logic Plus overload relay to
support RS-485 electrical communications standards. Up
to 99 Motor Logic Plus overload relays can be controlled
and monitored from one remote personal computer.

Modifications
No modification for 200–480 V
Add communication module for 200–480 V
No modification for 600 V
Add communication module for 600 V

Table 17.113: Communication Module
For Use With

Example

Class & Type

Form B 4 2
Motor Logic Plus overload relay with a current range of
6–27 A and modifications to add communication module
for an open style starter package.

Parts Kit
Description

Class 9999
Type

Modbus
Communication
Module

MB22

NEMA Size

8536 SA-SH
1–6

9065 SP

$ Price

171.00

Table 17.114: How to Order
To Order Specify:

•
•

Catalog Number

Class Number
Type Number

Class

Type

9999

AC04

Table 17.115: Full Voltage Controllers Only
Classes 8502, 8536, 8538, 8539, 8702, 8736, 8738, 8739, 8810, 8811 and 8812
Factory Modifications
Non-Compensated Bimetallic Overload Relays
Single Phase:
Types SB–SD (Sizes 0–2)b

Overload
Relays

a
b
c

17-36

Polyphase:
Two Element—For 2 Phase Only
Types SB–SD (Sizes 0–2)
Three Element
Types SB–SD (Sizes 0–2)
Type SG (Size 5)
Type SH (Size 6)
Ambient Compensated Bimetallic Overload Relays
Three Element
Types SB–SD (Sizes 0–2)
Types SE–SF (Sizes 3 & 4)
Type SG (Size 5)
Type SH (Size 6)

NEMA Size

Enclosure
Type

Form

Any

B1

—

35.60

35.60

Any

B1

—

35.60

Any
Any
Any

B2
B2
B2

—
—
—

1, 4, 7, 9, 12
Any
Any
Any

B
Y59
B
B

—
—
—
—

00

Overload Relays—General
Any
Y81
—
Modify Size 3 Type SE starters with melting alloy overload
relays to accept Type FB quick trip or SB slow trip thermal units
Substitute 9999 SO4 isolated alarm contact (N.O.)
Any
Y342
179.00
on melting alloy overload relay
Substitute 9999 SO5 isolated alarm contact (N.C.)
Any
Y344
179.00
on melting alloy overload relay
Size 7 uses a solid state overload relay as standard. See Class 8536 for complete details.
Single phase bimetallic overload relays for Type S Sizes 0–2 require two (2) thermal units per starter.
For Classes 8736, 8738 and 8739 Type SG, consult Schneider Electric CCC at (1-888-778-2733).

CP1

Discount
Schedule

0

1

2

3

4

5

6

7

35.60

—

—

—

—

—

35.60

35.60

—

—

—

—

—

35.60
—
—

35.60
—
—

35.60
—
—

—
—
—

—
—
—

—
35.60
—

—
—
35.60

—
—
—

a

64.00
—
—
—

64.00
—
—
—

64.00
—
—
—

—
64.00
—
—

—
—
64.00
—

—
—
—
64.00

—
—
—
—

a

—

—

—

179.00

179.00

179.00

179.00

179.00

179.00

—
64.00
—
—
N/C
179.00
179.00

—

—

—

—

179.00

179.00 c 179.00

—

a

179.00

179.00 c 179.00

—

a

© 2012 Schneider Electric
All Rights Reserved



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : mra632
Create Date                     : 2014:04:02 13:06:17Z
Modify Date                     : 2014:04:04 18:41:26-04:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Creator Tool                    : FrameMaker 9.0
Metadata Date                   : 2014:04:04 18:41:26-04:00
Producer                        : Acrobat Distiller 9.2.0 (Windows)
Format                          : application/pdf
Title                           : nema-contactors-and-staters-sd.book
Creator                         : mra632
Document ID                     : uuid:e30353b8-b5e3-4630-a97f-ffc898a40968
Instance ID                     : uuid:ef508ee8-bea6-4214-bb27-11e73dc0319d
Page Mode                       : UseNone
Page Count                      : 36
EXIF Metadata provided by EXIF.tools

Navigation menu