Nema Contactors And Staters Sd 558848 Catalog
235972-Catalog 235972-Catalog 235972-Catalog 785901 Batch7 unilog cesco-content
2014-07-05
: Pdf 558848-Catalog 558848-Catalog 785901 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 36
Download | |
Open PDF In Browser | View PDF |
Table of Contents IEC Style Disconnect Switches GS1 Fusible and LK3 Nonfusible, UL98 Tested GS1 Fusible and LK3 Nonfusible, Dimensions 17-2 17-5 UL508 Motor Disconnect Switches Mini-Vario and Vario™ Switches 17-8 NEMA Style Disconnect Switches NEMA Style Door-Mounted Disconnect Switches 17-9 Door-Mounted Operating Mechanisms Electromechanical Reduced Voltage Starter (p. 17-18) For Square D™ Circuit Breakers Approximate Dimensions 17-10 17-12 Bracket-Mounted Disconnect Devices Type T Disconnect Switches 17-13 Flexible Cable Mechanisms For Circuit Breakers 17-14 Disconnect Switch Accessories Flange Mounted, Variable Depth 17-15 Reversing Drum Switches Type A and B 17-17 Electromechanical Reduced Voltage Starters Description of All Types How to Order Autotransformer Starters Wye-Delta Starters (Open Transition) Wye-Delta Starters (Closed Transition) Part Winding Starters Approximate Dimensions 17-18 17-18 17-19 17-20 17-21 17-22 17-23 Multispeed Magnetic Starters Application Data Two-Speed Combination Starters Reversing Two-Speed Magnetic Starters Two-Speed Magnetic Starters Approximate Dimensions 17-24 17-26 17-27 17-28 17-29 Lighting Contactors Panelboard Lighting Contactors, Type PB 17-30 Well-Guard™ Pump Panel Reduced Voltage Type 17-31 Factory Modifications (Forms) Reduced Voltage Starters 17-32 Definite Purpose Contactors Reversing/Hoist, Type R 17-35 Thermal Overload Relays—NEMA Style Solid-State Overload Relay, Motor Logic™ Plus © 2012 Schneider Electric All Rights Reserved 17-36 17-1 17 NEMA Contactors and Starters NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Section 17 IEC Style Disconnect Switches GS1 Fusible and LK3 Nonfusible, UL98 Tested Class 9421 / Refer to Catalog 9421CT0301 17 The GS1 part numbers can be identified as follows. See Catalog 9421CT0301 for specific applications. NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Table 17.1: www.schneider-electric.us Identification System GS1 D U 3 Model GS1 Fusible (Class J fuse unless noted), LK3 Nonfusible Current Range, Operator Type (front operator unless noted), Accessory Type D 30 A front and side operation T 800 A (Class L if fused) DD 30 A Class CC front and side operation U 1000 A E 30 A W 1200 A EE 30 A Class CC AH handle G 60 A AHT handle with test J 100 A AE extension shaft M 200 A AD auxiliary contact holder Q 400 A AM auxiliary contact S 600 A UL Certification Poles—Number of Poles, 2 or 3 Note: All fusible switches through 400 A and nonfused switches through 200 A are equipped with a feature to test optional auxiliary contacts without energizing the load when the appropriate GS1AHT•••• handle is used. Table 17.2: Catalog No. 200 A Switch GS1MU3 Table 17.4: $ Price Compact GS1 Fusible IEC Style Disconnect Switches GS1DDU3 30 A, 3-pole, Class CC, use 5x5 shaft GS1DU3 30 A, 3-pole, Class J, use 5x5 shaft GS1 Fusible IEC Style Disconnect Switches GS1EEU3 30 A, 3-pole, Class CC , use 10x10 shaft GS1EU3 30 A, 3-pole, Class J, use 10x10 shaft GS1GU3 60 A, 3-pole, Class J, use 10x10 shaft GS1JU3ab 100 A, 3-pole, Class J, use 10x10 shaft GS1MU3ab 200 A, 3-pole, Class J, use 10x10 shaft GS1QU3ab 400 A, 3-pole, Class J, use 10x10 shaft GS1SU3ab 600 A, 3-pole, Class J, use 15x15 shaft GS1TU3ab 800 A, 3-pole, Class L, use 15x15 shaft Table 17.3: Catalog No. 30 A Side Handle GS1EERU30 Fusible Switches Description 237.00 260.00 237.00 260.00 336.00 536.00 1181.00 2252.00 3377.00 5061.00 Description $ Price 30 A, 2-pole, Class CC 204.00 GS1EERU30 30 A, 3-pole, Class CC 242.00 GS1AH01 Right side handle for GS1EERU20 & GS1EERU30 b Nonfusible Switches Description $ Price Compact LK3 Nonfusible IEC Style Disconnect Switches LK3DU3 30 A, 3-pole, 5x5 shaft LK3 Nonfusible IEC Style Disconnect Switches LK3GU3 60 A, 3-pole, use 10x10 shaft LK3JU3 100 A, 3-pole, use 10x10 shaft LK3MU3ab 200 A, 3-pole, use 10x10 shaft LK3QU3ab 400 A, 3-pole, use 15x15 shaft LK3SU3ab 600 A, 3-pole, use 15x15 shaft LK3TU3ab 800 A, 3-pole, use 15x15 shaft LK3UU3ab 1000 A, 3-pole, use 15x15 shaft LK3WU3ab 1200 A, 3-pole, use 15x15 shaft 218.00 263.00 458.00 1010.00 1910.00 2873.00 4301.00 5372.00 6450.00 Fusible Switches with Direct Mount Side Handle GS1EERU20 a Catalog No. 46.40 Shipped with line side terminal shrouds; for additional shrouds, see page 17-4. Terminal lug must be ordered separately—see page 17-4. Compact 30 A Switch LK3DU3 Example of the parts to order to build a complete GS or LK switch: Choose a Switch 600 A, LK3SU3 + Shaft + Shaft 200 mm, GS1AE6 Handle Assembly Black Handle, LK3AH150 + Lugs, if needed Lugs Kit, GS1AW503 For example: LK3SU3 (600 A nonfusible switch, use 15x15 shaft) + GS1AE6 (15x15 200 mm Type H shaft) + LK3AH150 (black/black, lockable) To add auxiliary contacts: For front-mounted contacts order GS1AD30 (front-mounted auxiliary contact holder) + GS1AM110 (NO contact for GS1AD10, 20, and 30) 17-2 CP1 Discount Schedule © 2012 Schneider Electric All Rights Reserved IEC Style Disconnect Switches GS1 Fusible and LK3 Nonfusible, UL98 Tested Class 9421 / Refer to Catalog 9421CT0301 www.schneider-electric.us Pistol Handles for Compact GS1 and LK3 for Use with Shaft Type D Type NEMA/UL IEC 1, 12 GS1AH101 GS1AH102 Type D—alternate handles for compact switches only IP54 Table 17.6: Yes Padlockable Color Yes Black Red/Yellow IEC Defeatable Padlockable 1, 3R, 12 IP54 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes Compact Shaft Kits GS1AE7/AE71 Shafts 5 mm x 5 mm Table 17.7: Catalog Number $ Price Off/On (O/I) GS1AH101 GS1AH102 51.00 Color Operation Catalog Number $ Price Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) GS1AH110 GS1AH120 GS1AHT110 GS1AHT120 GS1AH410 GS1AH420 GS1AHT410 GS1AHT420 62.00 62.00 117.00 117.00 46.60 46.60 78.00 78.00 Pistol Handles for Standard GS1 and LK3 Type NEMA/UL Operation Pistol Handles for Compact GS1 and LK3 for Use with Shaft Type G Type NEMA/UL Defeatable IEC Defeatable Padlockable Color Operation Catalog Number $ Price Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) GS1AH110 GS1AH120 GS1AHT110 GS1AHT120 GS1AH410 GS1AH420 GS1AHT410 GS1AHT420 62.00 62.00 117.00 117.00 70.00 70.00 117.00 117.00 Black Red/Yellow Black Red/Yellow Black Red/Yellow Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Off/On (O/I) Off/On (O/I) GS1AH130 GS1AH140 GS1AHT130 GS1AHT140 GS1AH430 GS1AH440 70.00 70.00 125.00 125.00 78.00 78.00 $ Price GS1 30–100 A and LK3 60–100 A (3 in. handles) 1, 3R, 12 IP54 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes GS1 200–400 A and LK3 200 A (5 in. handles) GS1AH110 GS1AH120 Type G—Standard Handle Design 1, 3R, 12 IP54 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes Use these shaft kits when using compact switches: Table 17.8: Pistol Handles for Use with Shaft Type H Type NEMA/UL IEC Defeatable Padlockable Color Operation Catalog Number No No Yes Yes Yes Black Red/Yellow Black Red/Yellow Off/On (O/I) LK3AH150 LK3AH160 LK3AH170 LK3AH180 233.00 233.00 386.00 386.00 Off/On (O/I) LK3AH150 LK3AH160 GS1AH170 GS1AH180 233.00 233.00 386.00 386.00 For LK3 400–1200 A GS1AE8/AE81 Shafts 5 mm x 5 mm 1, 3R, 4, 4X, 12 IP65 For GS1 600–800 A No Black No Red/Yellow Yes Yes Black Yes Red/Yellow Note: Now UL approved for indoor or outdoor applications. 1, 3R, 4, 4X, 12 Table 17.9: IP65 Shafts Length in. LK3AH160 GS1AE2/AE21 Shafts © 2012 Schneider Electric All Rights Reserved GS1AE6 mm Catalog No. Shaft 5 mm x 5 mm—For use with Pistol Handles, Type D 12.6 320 GS1AE7 15.7 400 GS1AE71 Shaft 5 mm x 5 mm—For use with Pistol Handles, Type G 12.6 320 GS1AE8 15.7 400 GS1AE81 Shaft 10 mm x 10 mm—For Standard GS1 and LK3 12.6 320 GS1AE2 15.7 400 GS1AE21 $ Price 18.60 23.30 18.60 23.30 20.30 24.90 Shaft 15 mm x 15 mm—For use with Pistol Handles, Type H 7.9 200 GS1AE6 32.60 15.7 400 GS1AE61 40.40 CP1 Discount Schedule 17-3 17 Table 17.5: NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Handles IEC Style Disconnect Switches GS1 Fusible and LK3 Nonfusible, UL98 Tested Class 9421 / Refer to Catalog 9421CT0301 www.schneider-electric.us 17 Accessories Table 17.10: Auxiliary Contacts NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Type GS1AD20 + GS1AM110 GS1AD10 + GS1AM110 Description For Compact LK3 / GS1 U = Upper or Standard products allow up to 4 auxiliary contacts without any extra Top mounted contact holders. Contact holder (for 5 to 8 auxiliary contacts) 10 A 1 N.O. Contact Block 600 Vac 1 N.C. Contact Block For LK3 60–200 A, GS1 30–400 A U = Upper or Contact holder required (for 1 to 8 upper auxiliary contacts) Top mounted 10 A 1 N.O. Contact Block 600 Vac 1 N.C. Contact Block 1 N.O. & N.C. Contact Block (max of two blocks—any mix) S = Side mounted a 2 N.O. & N.C. Contact Block (max of two blocks—any mix) 1 N.O. & N.C. Contact Block w/ Test (max of two blocks—any mix) S = Side mounted a 2 N.O. & N.C. Contact Block w/ Test (max of two blocks—any mix) For LK3 400–1200 A U = Upper or Contact holder (for 1 to 4 auxiliary contacts) Top mounted 10 A 1 N.O. Contact Block 600 Vac 1 N.C. Contact Block Catalog No. $ Price GS1AD10 46.70 GS1AM110 GS1AM101 14.70 14.70 GS1AD20 46.70 GS1AM110 GS1AM101 GS1AN11 GS1AN22 GS1ANT11 GS1ANT22 14.70 14.70 78.00 140.00 93.00 156.00 LK3AD30 46.70 GS1AM110 GS1AM101 14.70 14.70 For GS1 600–800 A 1 N.O./N.C. Contact GS1AMU3 57.00 Micro-switch (top mounted) 2 N.O./N.C. Contact GS1AMU4 83.00 a Cannot be mixed. A single switch must use all GS1AN11/GS1AN22 contact blocks or all GS1ANT11/GS1ANT22 contact blocks. A GS1AN• • contact block may not be used on the same switch as a GS1ANT• •. GS1AD30 + GS1AM110 Table 17.11: Terminal Lugs For Use On Wire Size Compact GS1/LK3 GS1 30 A CC GS1 30 A J GS1/LK3 60 A J LK3 100 A GS1 100 A GS1/LK3 200 A GS1/LK3 400–600 A b GS1/LK3 800 A / LK3 1000 A b LK3 1250 A b b Cu Cu Cu Cu Cu Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Lugs per Kit — — — — — 6 6 6 6 12 Catalog No. $ Price Standard Standard Standard Standard Standard GS1AW303 GS1AW403 GS1AW503 GS1AW803 GS1AW903 — — — — — 59.00 98.00 197.00 246.00 395.00 Terminal Shrouds For Use On Terminal Shrouds Wire Type GS1 600–800 A and LK3 800–1250 A can receive 1 lug for 3 cables per terminal or 2 lugs for 2 cables per terminal. Table 17.12: Terminal Lugs #14–#10 #14–#10 #14–#10 #10–#3 #14–#2/0 #14–2/0 #6–3/0 2 x 2–2 x 600 3 x 2–3 x 600 4 x 2–4 x 600 # of Wires per Lug 1 1 1 1 1 1 1 2 3 2 Catalog No. $ Price For Line or Load Side c Compact GS1/LK3 Standard — All GS1/LK3 30 A Standard — All GS1/LK3 60 A Standard — LK3 100 A Standard — GS1 100 A d GS1AP33 101.00 GS1/LK3 200 A d GS1AP43 132.00 GS1 400 A GS1AP63 213.00 LK3 400–600 A LK3AP63 86.00 GS1 600–800 A GS1AP83 140.00 LK3 800–1250 A LK3AP83 101.00 c All GS1 and LK3 switches supplied with line side shrouding. d Three-piece kit for either line or load side. Table 17.13: For Use On Shorting Links Shorting Links per Kit Catalog No. $ Price 3 GS1AU203 GS1AU303 GS1AU403 GS1AU503 GS1AU803 29.60 41.90 62.10 93.00 156.00 GS1 60 A GS1 100 A GS1 200 A GS1 400 A GS1 600–800 A Table 17.14: Shaft Padlocking Kit For Use On Compact GS1/LK3 LK3 60–200 A GS1 30–400 A LK3 400–1250 A Catalog No. Standard $ Price — Shorting Links 17-4 CP1 Discount Schedule © 2012 Schneider Electric All Rights Reserved IEC Style Disconnect Switches GS1 Fusible and LK3 Nonfusible, Dimensions Class 9421 / Refer to Catalog 9421CT0301 www.schneider-electric.us 1.83 Door Drilling 3.75 0.125 96.5 2 ø 4.5 0.59 1.47 2.5 65 1 63 25.6 2.48 ø 31 -OFF 90° -ON 45 1.78 79.5 FIX 3.125 116 4.56 1.25 2 15 37.3 50 GS1DDU3 Compact CC 30 A 2.75 2.0 0.13 70 Test Position 50 4 ø 4.5 3.0 ø M165 FIX 76.2 3 18.3 0.72 50 17 2.0 65° o -OFF 3.25 1.25 83.8 ø 31 90° -ON GS1AH/AHT110, 120, 410, or 420 1.83 4.13 Door Drilling 46.5 105.5 1.47 2.5 65 0.059 37.3 15 0.13 2 ø 4.5 1.25 3.38 84 4.56 116 28 1.0 2.0 OFF 63 2.48 ø 31 50 GS1DU3 Compact J 30 A 90° GS1AH110 or 120 -ON 2.75 2.0 0.13 70 2 ø 4.5 FIX Test Position 50 o -OFF 50 3.88 2.0 0.63 15.8 65° FIX ø 0.19 3.0 7.62 99 90° 1.25 ø 31 -ON GS1AH/AHT110, 120, 410, or 420 GS1EEU3, GS1 CC 30 A 5.69 2.75 144 1.13 70 Fix 29 Door Drilling 0.13 4 Ø 4.5 2.00 50 5.88 133 2.00 149 © 2012 Schneider Electric All Rights Reserved 0-OFF 50 2.63 3.00 67 76.2 Ø 31 3.88 62 99 CP1 Discount Schedule 90° 1.25 2.44 Test Position 65° Fix 5.25 -ON Dimensions: NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Dimensions in. mm 17-5 IEC Style Disconnect Switches GS1 Fusible and LK3 Nonfusible, Dimensions Class 9421 / Refer to Catalog 9421CT0301 17 NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS GS1EU3/GS1GU3, GS1 30 A/60 A J 5.63 2.75 143 70 1.50 3.50 38 Door Drilling 89 .13 2.00 4 Ø 4.5 Fix 5.25 133 5.88 50 Test Position 65° 2.00 149 3.00 67 90° 1.25 76.2 Mounting Hole Dimension: 0.19 in. (4.8 mm) 0-OFF 50 2.63 www.schneider-electric.us Ø 31 -ON 2.75 70 6.75 171 GS1JU3, GS1 100 A J 2.75 5.63 70 2.06 143 87 0.13 Fix 6.56 167 183 .25 2.00 4 Ø 4.5 7.19 Terminal Lugs 2/0 Max. Door Drilling 3.44 52 50 2.00 3.00 84 Ø 31 16 .88 90° 1.25 76.2 Mounting Hole Dimension: 0.19 in. (4.8 mm) .63 0-OFF 50 3.31 Ø6.9 Test Position 65° 22 .75 19 -ON 3.31 8.25 84 210 GS1MU3, GS1 200 A J 6.00 2.75 Fix 2.44 62 152 70 3.44 Door Drilling 87 .13 Fix 7.50 191 8.13 Terminal Lugs 3/0 Max. .44 2.00 50 4 Ø 4.5 2.00 207 3.75 127 95 1.00 25 0-OFF 50 5.00 11 Ø1 1.6 Test Position 65° 1.50 90° 1.25 Ø 31 Mounting Hole Dimension: 0.19 in. (4.8 mm) 38 -ON 1.13 29 3.69 94 9.44 240 GS1QU3, GS1 400 A J 2.81 Fix 2.81 72 5.56 2.75 72 141 3.44 70 50 4 Ø 4.5 Fix 8.81 224 0-OFF 50 4.44 5.00 112 Ø 31 303 GS1SU3/GS1TU3, GS1 600 A J and 800 A L 1.50 3.13 90° 1.25 127 10 Ø 10.2 Test Position 65° 2.00 363 11.94 .38 2.00 0.13 14.31 Terminal Lugs 2 x 600 MCM Max. Door Drilling 87 38 80 Mounting Hole Dimension: 0.25 in. (6.3 mm) -ON Ø .25 6 2.06 2.88 73 52 Door Drilling Ø 9.38 2.50 64 Fix 13.63 346 Fix 9.88 251 2.00 3.13 1.50 38 80 7.13 181 19.38 492 4.13 .25 106 7 Locking 55˚ 9.88 250 6.00 14.25 2.00 51 51 152 7.50 362 Ø 1.25 31 0.13 Ø 4.5 Terminal Lugs 2X600 MCM Max. 3X600 MCM Max. Ø 44 Ø .38 2.75 11 10 69 190 2.50 64 3.88 2.38 59 4.75 4.75 120 120 98 4.00 7.50 .50 13 100 20.38 517 190 3.13 80 1.50 3.56 38 1.56 2.88 3.00 91 73 Mounting Hole Dimension: 0.38 in. (9.6 mm) 40 76 Dimensions: 17-6 CP1 Discount Schedule in. mm © 2012 Schneider Electric All Rights Reserved IEC Style Disconnect Switches GS1 Fusible and LK3 Nonfusible, Dimensions Class 9421 / Refer to Catalog 9421CT0301 www.schneider-electric.us 2.59 3.78 96 66 0.59 15 1.94 37 1.00 25 0.75 19 1.00 25 Door Drilling 0.13 2.00 2 Ø 4.5 1.83 116 1.78 Fix 3.13 45 80 1.25 3.84 0-OFF Ø 31 98 0.56 14 90° -ON 2.48 63 Fix Ø .19 M5 18 2.75 ø 0.19 3.88 70 FIX 1.50 5 99 Door Drilling 3.50 38 89 2.00 .13 50 Test Position 4 Ø 4.5 FIX 5.25 5.88 2.63 90° 1.25 76.2 Mounting Hole Dimension: 0.19 in. (4.8 mm) 0-OFF 50 3.00 67 65° 2.00 133 149 17 0.72 LK3GU3/LK3JU3, LK3 60 A/100 A Mounting Hole Dimension: 0.19 in. (4.8 mm) 51 46 4.56 Ø 31 -ON 2.75 70 6.69 170 LK3MU3, LK3 200 A 3.44 2.75 2.44 Ø .19 5 87 70 62 Door Drilling 0.13 Terminal Lugs 3/0 Max. .44 2.00 4 Ø 4.5 50 Fix 7.50 191 8.13 3.75 127 95 0-OFF 50 5.00 11 Ø11.6 Test Position 65° 2.00 206 1.00 1.50 90° 1.25 Ø 31 25 38 Mounting Hole Dimension: 0.19 in. (4.8 mm) 1.13 -ON 29 3.69 94 9.50 241 LK3QU3/LK3SU3, LK3 400 A/600 A Terminal Lugs 2 x 600 MCM Max. 6.56 166 3.13 1.56 .38 1.63 5.00 Fix 12.63 320 127 Fix 6.88 175 2.31 2.00 20 51 1.50 38 Mounting Hole Dimension: 0.25 in. (6.3 mm) .13 4 Ø 4.5 98 0.56 11.00 80 Ø 31 191 14 3.13 1.25 3.88 0.81 2.00 51 7.50 59 10 Ø 10.2 Door Drilling 41 80 40 2.88 73 Fix 10.06 255 279 LK3TU3/LK3UU3/ LK3WU3, LK3 800 A/1000 A/1250 A Door Drilling 6.56 6.81 2.50 173 166 4.75 51 Ø 1.25 31 Ø 4.5 Terminal Lugs 2X600 MCM Max. 3X600 MCM Max. Ø 44 Ø .38 11 10 330 59 Fix 6.88 175 0.81 7.50 20 20 2.00 51 1.56 0.13 13.00 2.31 0.81 2.00 40 121 64 14.63 2.50 3.88 1.56 40 191 64 98 Fix 13.69 347 3.13 80 1.50 3.56 38 1.56 2.88 3.00 91 Mounting Hole Dimension: 0.38 in. (9.6 mm) 40 372 73 76 Dimensions: © 2012 Schneider Electric All Rights Reserved CP1 Discount Schedule NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS LK3DU3, Compact LK3 30 A in. mm 17-7 UL508 Motor Disconnect Switches Mini-Vario and Vario™ Switches Refer to Catalog 9421CT0301 www.schneider-electric.us 17 Vario NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS The Vario Motor Disconnect Switch is also offered as an enclosed switch made of corrosion resistant material. The 3-pole version makes the Vario switch ideal for manual motor control applications. The switches are compact, easy to wire and connect, and come undrilled to allow variable cable entry positions. NOTE: VCGUN enclosures are UL approved. Table 17.15: Non-Metallic Enclosed Switches a Ampere Size IEC Catalog No. $ Price 20 32 VC1GUN 239.00 25 40 VC2GUN 287.00 45 63 VC3GUN 345.00 63 80 VC4GUN 381.00 100 125 VC5GUN 548.00 115 175 VC6GUN Assembled, includes switches mounted in enclosure with handle. 845.00 Non-Metallic Enclosure a Table 17.16: .25 Ø 6.2 IP55-PVC 3-Pole, NEMA Type 1 & 12 UL Non-Metallic Enclosed Switch Dimensions a Dimensions No. of Poles Catalog No. a Legend Plate Holder d a VC1GU–VC6GU 17-8 c d e f mm in. mm in. mm in. mm in. mm in. mm 6.7 170 4.1 105 3.2 82 4.8 122 2.1 53 5.0 128 6.7 170 5.3 135 3.3 85 5.1 130 3.7 95 5.2 131 VC5GU–VC6GU 11.0 a UL Rated, NEMA Type 1, 12, IP55. 280 8.6 220 5.0 126 7.9 201 7.5 190 8.6 203 VC1GU–VC2GU c b in. VC3GU–VC4GU e b a 3 f Table 17.17: Vario Manual Motor Control Switches, IEC kW Rating 3-Pole Switch Body Rating (A) IEC 230 V 240 V 400 V 415 V 500 V 20 4 4 5.5 5.5 7.5 11 25 5.5 5.5 7.5 7.5 11 15 690 V 32 5.5 5.5 11 11 11 15 40 7.5 7.5 15 15 18.5 15 22 63 15 15 22 22 30 80 18.5 18.5 30 30 37 30 125 22 22 37 37 45 37 175 30 30 45 45 55 45 CP1 Discount Schedule © 2012 Schneider Electric All Rights Reserved NEMA Style Disconnect Switches NEMA Style Door-Mounted Disconnect Switches Refer to Catalog 9420CT9701 www.schneider-electric.us Table 17.18: Disconnect Switches (without fuse clips or shorting straps) Table 17.22: Max. Horsepower Ratinga Rating (A) 120 V 0–1 2 3 4 30 60 100 200 5 10 15 25 200– 240 V 10 20 30 50 480 V 600 V Catalog Number 20 40 60 100 25 50 75 100 D10S1 D10S2 D10S3 D10S4 $ Price 270.00 292.00 452.00 860.00 a Rating (A) Max. Horsepower Rating a 200– 240 V 10 20 30 50 120 V 0–1 30 5 2 60 10 3 100 15 4 200 25 a Nonfused ratings. Line Shield Table 17.19: Rating (A) 480 V 600 V Catalog Number 20 40 60 100 25 50 75 100 D10S1H D10S2H D10S3H D10S4H B F Complete Kit with Handle, Shaft, and Actuator A E Centerline of Switch Operating Shaft I J D C Enclosure Interior Depth—Inches 5–6 6–10 10–16 6 12 30, 60, 100, 200 Shaft only Table 17.20: $ Price 320.00 352.00 544.00 1154.00 Catalog Number D11SF4 D11SF10 D11SF16 D11SH10 D11SH16 $ Price 106.00 118.00 130.00 26.20 32.80 Auxiliary Electrical Interlock (for mounting on 30–200 A disconnect switch a) Block Description (with switch contacts open) Catalog Number D11N0 D11NC D11N0C D11N00 D11N0C2 1 N.O. 1 N.C. 1 N.O. and 1 N.C. 2 N.O. 2 N.O. and 2 N.C. a One block per switch. Table 17.21: Wire Type #14–#8 #14–#4 #14–#1/0 #6–250 kcmil Cu Cu Al–Cu Al–Cu Fuse Clip Kits Fuse Clip Rating a Catalog Number Amperes AC Volts Type No Fuse D12C01 0–30 250 H, K D12C21 0–30 250 R D12CR21 0–30 600 H, K D12C61 0–30 600 R D12CR61 30 A 0–30 600 J D12CJ1 31–60 250 H, K D12C22 31–60 600 H, K D12C62 31–60 600 R D12CR62 31–60 600 J D12CJ2 61–100 250 H, K D12C23 No Fuse D12D02 0–30 250 R D12DR21 0–30 600 H, K D12D61 0–30 600 R D12DR61 31–60 250 H, K D12D22 31–60 250 R D12DR22 60 A 31–60 600 H, K D12D62 31–60 600 R D12DR62 31–60 600 J D12DJ2 61–100 250 H, K D12D23 61–100 600 H, K D12D63 61–100 600 J D12DJ3 61–100 600 R D12DR63 No Fuse D12E03 31–60 250 H, K D12E22 31–60 600 H, K D12E62 61–100 250 H, K D12E23 61–100 250 R D12ER23 100 A 61–100 600 H, K D12F63 61–100 600 R D12FR63 61–100 600 J D12EJ3 101–200 250 H, K D12F24 600 H, K D12F64 101–200 101–200 600 J D12FJ4 No Fuse D12F04 61–100 600 H, K D12F63 101–200 250 H, K D12F24 200 A 101–200 250 R D12FR24 101–200 600 H, K D12F64 101–200 600 R D12FR64 101–200 600 J D12FJ4 a Continuous current should not exceed switch rating (size). Fuse clip kits should be sized to accommodate inrush. Rotary Handle Operator Kits and Shafts Description Wire Range a D10 Switch Size Kits include: Handle, Shaft, and Actuator NEMA Type 1, 3, 3R, 4, and 12 G H 30 60 1 100 200 One conductor per lug. Table 17.23: 600 V—With Service Entrance Rating Starter NEMA Size Number Per Pole Rating (A) 600 V—Without Service Entrance Rating Starter NEMA Size Lug Data $ Price 79.00 79.00 116.00 116.00 130.00 Interrupting and Withstandability Ratings Rating (A) Interrupting Rating Amperes Symmetrical 600 Vac, 3Ø Withstandability I2T (Amperes2 seconds) 30 1,200 0.38 x 106 60 1,800 1.28 x 106 100 2.000 2.62 x 106 200 3,600 5.25 x 106 $ Price 8.30 16.30 65.00 24.50 65.00 49.30 24.50 49.30 82.50 57.50 65.00 24.50 65.00 24.50 65.00 23.80 82.50 41.00 82.50 57.50 65.00 115.00 106.30 113.80 49.30 41.00 41.00 32.50 115.00 90.00 115.00 115.00 106.30 122.50 140.00 82.50 90.00 106.30 140.00 122.50 135.00 140.00 Note: These switches are for motor circuit applications. Table 17.24: Width Mounting Hole Dimensions Depth A B C D E F G H I J Ka lb 30 7-5/16 4-15/32 5-7/8 3-15/32 6 3-15/32 1-7/8 13/32 5-7/16 3-1/4 4-3/32 4-11/32 60 7-5/16 4-15/32 5-7/8 3-15/32 6 3-15/32 1-7/8 13/32 5-7/16 3-1/4 4-11/32 4-11/32 100 9-27/32 5-11/32 8-3/16 4-5/8 5-13/16 3-13/16 2-11/16 51/64 7-5/16 4-3/16 5-23/32 4-27/32 12-3/16 7-7/32 8-3/16 4-5/8 5-13/16 3-13/16 2-11/16 51/64 7-5/16 4-3/16 5-23/32 4-27/32 200 a b © 2012 Schneider Electric All Rights Reserved Switch Dimensions (in inches) Length Rating (A) Maximum depth with largest fuse. Depth including insulating barrier on service entrance switches. CP1 Discount Schedule 17-9 17 The D10 disconnect switch features high I2T rating, longer contact life, visible contact indication, fuse-mounting flexibility, dead-front construction, and auxiliary interlocks. A complete installation includes a D10 disconnect switch, D11 handle operator, and D12 fuse clip kit. The D10 accepts Class H, K, J, or R fuses, or can be used for nonfusible applications. The D10 disconnect switch is operated by a cast metal handle operator that is lockable in the “Off” position and defeatable in the “On” position. NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS File D10 Door-Mounted Operating Mechanisms For Square D™ Circuit Breakers Class 9421 / Refer to Catalog 9420CT9701 www.schneider-electric.us 17 Type L Circuit Breaker Mechanisms NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Type L door-mounted, variable-depth operating mechanisms feature heavy duty, all metal construction with trip indication. All can be padlocked in the “Off” position when the enclosure door is open. Further, the handle assemblies can be locked “Off” with up to three padlocks, which also locks the enclosure when the door is closed. (The 3” handle accepts one padlock.) Complete kits are rated for NEMA Type 1, 3R, and 12 enclosures. They include a handle assembly, operating mechanism, and shaft assembly. Table 17.25: Complete Kits Complete Kit Does Not Include Circuit Breaker No. of Poles Frame Size (A) Includes: Operating Mechanism Standard 6 in. Handle Standard Shaft Kit Mounting Type $ Price Depth a Min. – Max. Use With Operating Mechanism Circuit Breaker or Interrupter Type GJL Includes: Operating Mechanism Short 3 in. Handle Long Shaft Kit Mounting Type $ Price Depth a Min. – Max. 3 75, 100 LG1 140.00 5-1/2–10-1/4 LG4 158.00 5-1/2–20-7/8 LG3 FAL, FCL, FHL 2–3 100 LN1 140.00 5-1/2–10-7/16 LN4 158.00 5-1/2–21 LN3 198.00 KAL, KCL, KHL 2–3 250 LP1 171.00 6-1/4–11-3/16 LP4 189.00 6-1/4–21-3/4 LP3 230.00 6-1/4–21-3/4 LJ3 230.00 5-1/2–21-3/8 LALc, LHLc, Q4L 2–3 400 LR1 242.00 6-5/16–10-7/8 LR4 255.00 6-5/16–21-1/2 MEL, MXL 2–3 800 LT1b 242.00 7-3/16–11-5/8 LT4b 255.00 7-3/16–22-1/4 MAL, MHL 2–3 1200 LT1b 242.00 7-3/16–11-5/8 LT4b 255.00 7-3/16–22-1/4 NAL, NCL, NEL, NXL 2–3 1200 LX1b 242.00 8-1/4–12-3/4 LX4b 255.00 8-1/4–23-3/8 Table 17.26: 198.00 5-1/2–20-7/8 5-1/2–21 3 in. handles are not recommended for use with these circuit breakers. Component Parts Circuit Breaker or Interrupter Type GJL Standard Handle Assemblies Type 1, 3R, 12 3 in. Handle Assemblies Type 1, 3R, 12 Use With No. of Poles Frame Size (A) Type $ Price Type Operating Mechanism (Lockout Included) $ Price Type $ Price Standard Shaft (Support Bracket Not Required) Mounting Depth a Min. – Max. Long Shaft (Support Bracket Included) Type $ Price Mounting Depth a Min. – Max. Type $ Price 3 75, 100 LH3 90.00 LH6 50.00 LG7 68.00 5-1/2–10-7/16 LS8 21.50 5-1/2–21 LS13 35.60 FAL, FCL, FHL 2–3 100 LH3 90.00 LH6 50.00 LF1 71.00 5-1/2–10-7/16 LS8 21.50 5-1/2–21 LS12 35.60 KAL, KCL, KHL 2–3 250 LH3 90.00 LH6 50.00 LK1 105.00 6-1/4–11-3/16 LS8 21.50 6-1/4–21-3/4 LS12 35.60 3 in. handles LH6 50.00 LL1 170.00 6-5/16–10-7/8 LS8 21.50 6-5/16–21-1/2 are not MEL, MXL 2–3 800 50.00 LM1 170.00 7-3/16–11-5/8 LS8 21.50 7-3/16–22-1/4 recommended LH8 MAL, MHL 2–3 1200 for use with LH8 50.00 LM1 170.00 7-3/16–11-5/8 LS8 21.50 7-3/16–22-1/4 these circuit NAL, NCL, NEL, NXL 2–3 1200 breakers. LH8 50.00 LX7 170.00 8-1/4–12-3/4 LS8 21.50 8-1/4–23-3/8 a Mounting depth in inches, measured from circuit breaker mounting surface (control panel) to outside of enclosure door. b Types LT1, LT4, LX1, and LX4 include an 8 in. handle rather than a 6 in. handle. c These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix. LS10 35.60 LS10 35.60 LS10 35.60 LS10 35.60 LALc, LHLc, Q4L Table 17.27: 2–3 400 NEMA Type 4 and 4X Handle Assemblies a Use With 3 in. Handle Assembly Circuit Breaker or Interrupter Type GJL Standard Handle Assembly Includes: Operating Mechanism Standard 6 in. Handle Long Shaft Kit Mounting Type $ Price Depth a Min. – Max. Standard Handle Assemblies NEMA Type 1, 3R, 4, 12 (Painted) 3 in. Handle Version NEMA Type 1, 3R, 4, 4X, 12 (Chrome Plated) NEMA Type 1, 3R, 4, 12 (Painted) NEMA Type 1, 3R, 4, 4X, 12 (Chrome Plated) No. of Poles Frame Size (A) Type $ Price Type $ Price Type $ Price Type $ Price 3 75 LH46 90.00 LC46 149.00 LH43 165.00 LC43 233.00 FAL, FCL, FHL 2–3 100 LH46 90.00 LC46 149.00 LH43 165.00 LC43 233.00 KAL, KCL, KHL 2–3 250 LH46 90.00 LC46 149.00 LH43 165.00 LC43 233.00 LAL, LHL, Q4L 2–3 400 LH46 90.00 LC46 149.00 MEL, MXL 2–3 800 LH48 90.00 LC48 149.00 MAL, MHL 2–3 1000 LH48 90.00 LC48 149.00 NAL, NCL, NEL, NXL 2–3 1200 LH48 90.00 LC48 a Due to gasketing, NEMA Type 3 and 4 handle assemblies are not trip indicating. 149.00 Table 17.28: IEC Style Operating Mechanisms a Color Red/Yellow Black Contains support bracket. Table 17.29: Operating Mechanism (Lockout Included) Type 1, 4, 4X, 12 Circuit Breaker or Interrupter Type GJL 3 in. handles are not recommended for use with these circuit breakers. Type NW3 $ Price 90.00 NW3B 90.00 Type LG8 $ Price 71.00 Extension Shafts Mounting Depth Type $ Price Min. 6-1/8 Max. 10-3/4 NS16 28.70 6-1/8 17-7/8 NS336a 35.60 Electrical Interlock Kits—Class 9999 a Description Class Type $ Price Single-Pole, Double-Throw 9999 R47 131.00 Double-Pole, Double-Throw 9999 R48 221.00 a Optional accessory for use with 9421L operating mechanisms. Not used with GJL, NAL, NCL, NEL, NXL, NSF, NSJ, PowerPact™ C, D, H, and J circuit breakers; use field-installed circuit breaker interlocks instead. 17-10 CP1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Approximate Dimensions Door-Mounted Operating Mechanisms 3.50 Min. 1.38 Refer to NEC Article 430-10 for minimum dimension from top mounting hole to wall or barrier X to ensure adequate wire bending space. 45 1.18 30 .50 13 NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Class 9421 / Refer to Catalog 9420CT9701 www.schneider-electric.us 35 L 4.72 1.77 45 120 CLHandle Mechanism 3.94 100 Screw Driver Interlock Pin Location .45 7 Door Thickness CLHandle Mechanism (2) #8-32 Tap 17 .28 Maximum 12 2.38 60 H Mounting Depth a Panel drilling for GJL circuit breaker and operating mechanism Table 17.30: Shaft Cutting Dimensions Class a L = Overall shaft length H = Distance from inside of enclosure door to circuit breaker mounting surface Type Shaft Length Formula H = Standard Shaft H = Long Shaft Min. Max. L = H–2.50 5.50 10.25 9421 LG7, LG1, LG4, LG3 64 140 260 L = H–2.88 5.50 10.44 9421 LF1, LN1, LN3, LN4 73 140 265 L = H–3.63 6.25 11.19 9421 LK1, LP1, LP3, LP4 92 159 284 L= H–3.13 6.31 10.88 9421 LL1, LR1, LR4 79 160 276 L= H–4.00 7.18 11.63 9421 LM1, LT1, LT4 102 182 295 L= H–5.17 8.25 12.75 9421 LX7, LX1, LX4 131 210 324 Mounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door. 3.25 Minimum 83 (Both Sides) 7.00 4.50 2.25 114 Hinge Point of Door 1.50 38 57 .75 19 1.63 R 41 1.56 40 178 Minimum to wall or barrier to ensure adequate wire bending space to lug surface when maximum wire size is used with standard lugs. Refer to NEC Article 430-10. CL Handle Mechanism Min. 5.50 140 5.50 140 6.25 159 6.31 160 7.18 182 8.25 210 Max. 20.85 530 21.00 533 21.75 552 21.50 546 22.25 565 23.38 594 3.25 Minimum 83 13.50 (Both Sides) 4.50 2.25 114 Hinge Point of Door 1.50 38 57 .75 19 1.81 46 343 Minimum to wall or barrier to ensure adequate wire bending space to lug surface when maximum wire size is used with standard lugs. Refer to NEC Article 430-10. 5.13 7.13 6.00 152 181 CL Handle & Ckt. Bkr. T oggle (4) #8-32 Tap CL Handle & Ckt. Bkr. T oggle 130 1.63 R 41 6.00 152 (4) #10-24 Tap C30080-120 Panel drilling for FAL, FCL, and FHL circuit breakers and operating mechanisms Panel drilling for KAL, KCL, and KHL circuit breakers and operating mechanisms Dimensions: © 2012 Schneider Electric All Rights Reserved in. mm 17-11 Approximate Dimensions Door-Mounted Operating Mechanisms Class 9421 / Refer to Catalog 9420CT9701 17 NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS 6.00 Minimum 152 (Both Sides) Hinge 6.00 Point 3.00 152 of Door 76 487 2.00 2.00 51 .88 22 Minimum to wall or barrier to ensure adequate wire bending space to lug surface when maximum wire size is used with standard lugs. Refer to NEC Article 430-10. 51 1.00 8.00 Minimum 203 (Both Sides) Hinge 4.50 Point 114 of Door 19.19 25 CL Circuit Breaker 1.63R 119 CL Handle (4) #12-24 Tap 76 1.50 3.09 79 (4) 1/4-20 Tap 1.03 26 9.25 4.68 3.00 CL Circuit Breaker (4) 1/4-20 Tap A 14 CL Handle 51 (4) 5/16-18 Tap .56 41 235 X Minimum to wall or barrier to ensure adequate wire bending space to lug surface when maximum wire size is used. Refer to NEC Article 430-10. 2.00 38 125 40 229 42 4.937 116 9.00 1.66 1.59 4.57 www.schneider-electric.us CL Handle 3.50 89 2.68 68 .38 CL Handle B 10 .44 11 203 11 .38 .44 8.00 10 1.63R 6.00 41 152 5.09 .88 10.19 7.19 22 129 259 183 Panel drilling for LAL, LHL, and Q4L circuit breakers and operating mechanisms Panel drilling for MAL, MEL, MHL, and MXL circuit breakers and operating mechanisms Dimensions = in. (mm) Circuit Breaker Type A B MAL, MHL 10.69 (272) 14.00 (356) MEL, MXL 11.47 (291) 14.75 (375) C L 9.00 Minimum (Both Sides) Handle Mechanism 229 15.00 381 Hinge 3.16 7.50 Point 80 191 of Door 5.00 1.66 127 42 (4) 1/4-20 Tap 2.50 64 12.13 308 9.50 241 CL Handle Mechanism 8.75 222 1.63R 41 8.00 203 CL Circuit Breaker 8.50 216 Panel drilling for NAL, NCL, NEL, and NXL circuit breakers and operating mechanisms Dimensions: 17-12 in. mm © 2012 Schneider Electric All Rights Reserved Bracket-Mounted Disconnect Devices Type T Disconnect Switches www.schneider-electric.us Table 17.31: Bracket-Mounted Operating Mechanisms for Use With Square D™ Circuit Breakers The circuit breaker operating mechanisms listed below are shipped with the external operating handle assembled to a bracket. Circuit breakers are not included and must be ordered separately. A trim plate is provided with each kit to prevent any mounting screws from being accessible from the front and also to provide an attractive installation.The operating handle is Type A1. These switches can be used with Class 9423 door closing mechanisms. Operating Mechanism Use With Circuit Breaker or Interrupter Type No. of Poles Right Hand Flange Mounting Frame Size (A) Cat. No. $ Price FAL, FHL 2–3 100 BN1 257.00 KAL, KHL 2–3 250 BP1 270.00 LALa, LHLa, Q4L 2–3 400 BR1 543.00 a These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix. Table 17.32: Electrical Interlock Kits—Class 9999 Optional accessory for use with circuit breaker operating mechanisms listed to the left and the flexible cable mechanisms listed below, except GJL. Description Single Pole, Double Throw Double Pole, Double Throw Class Type $ Price 9999 9999 R26 R27 131.00 243.00 Note: Not used with GJL; use field installed circuit breaker interlocks. 0.38 17 Note: Some enclosures may not accept the listed bracket-mounted operating mechanisms; contact the enclosure manufacturer. F 10 Table 17.33: Dimensions C A C D Min. Enclosure Deptha F in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) BG1, BN1 8.75 (222) 7.13 (181) 1.13 (29) 6.50 (165) 8.00 (203) BP1 9.13 (232) 7.38 (187) a The minimum enclosure depth is greater than Dimension D since additional space is needed when mounting the mechanism. Note: Back panel support is recommended for Types TFB1, 2, and 3. Other devices may also require support if the flange is not sufficiently rigid. Type D Disconnect Device 0.38 10 Disconnect Device ON A E OFF 0.38 10 Non Fused and Circuit Breaker Fused (2) 0.38 Dia. Mounting Holes 10 (For back panel support if necessary.) For use with Square D circuit breakers and Class 9422 A handle operators. Especially designed for tall, deep enclosures where placement flexibility is required. See Digest 176 page 8-24 for dimensions. Table 17.34: Class 9422—Flexible Cable Mechanisms for Use With Square D Circuit Breakers Cable Mechanism Cable Length Catalog No. 36 in. CGJ30 48 in. CGJ40 GJL 3 100 60 in. CGJ50 120 in. CGJ10 36 in. CFA30 FAL, FHL 2, 3 100 60 in. CFA50 120 in. CFA10 36 in. CKA30 KAL, KHL 2, 3 250 60 in. CKA50 120 in. CKA10 36 in. CLA30 LALa, LHLa, Q4L 2, 3 400 60 in. CLA50 120 in. CLA10 a These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix. Circuit Breaker Type Table 17.35: No. of Poles Frame Size (A) $ Price 273.00 291.00 291.00 333.00 273.00 291.00 333.00 288.00 305.00 347.00 486.00 504.00 548.00 Cable Mechanisms with A1 Handle Catalog No. $ Price CGJ31 417.00 CGJ41 432.00 CGJ51 432.00 CGJ11 476.00 CFA31 417.00 CFA51 432.00 CFA11 476.00 CKA31 431.00 CKA51 446.00 CKA11 489.00 CLA31 630.00 CLA51 647.00 CLA11 689.00 Class 9999 Auxiliary Contact Kits for Disconnect Switches and Circuit Breakers SPDT Class DPDT Type Type $ Price Type $ Price R8 87.00 R9 243.00 Disconnect Switches 9422 TF Circuit Breaker Operating Mechanisms 9421 LF, LK, LL, LM, LN, LP, LR, LT R47 131.00 R48 221.00 9422 RM, RN, RP, RR, RT R26 131.00 R27 243.00 9422 CFA, CKA, CLA, CSF R26 131.00 R27 243.00 Note: No external auxiliary contacts are available for the following circuit breakers: GJL circuit breakers must use internal auxiliary contacts, catalog number AAC. PowerPact D circuit breakers must use internal auxiliary contacts, catalog number AAC. Note: For additional variations, contact the Customer Care Center (CCC) at 1-888-778-2733. © 2012 Schneider Electric All Rights Reserved CP1 Discount Schedule NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Class 9422 / Refer to Catalog 9420CT9701 17-13 Flexible Cable Mechanisms For Circuit Breakers Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us 17 Dual Cable Operating Mechanisms for Square D™ Circuit Breakers NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Dual cable operator mechanisms are designed for use with Square D GJL circuit breakers. The cable mechanisms allow for a single handle operator, Class 9422A1, to operate both circuit breakers. The cable mechanism is designed especially for tall, deep enclosures where placement flexibility is required. There are numerous cable arrangements to choose from to accommodate many applications. Features • • • • • Separate cables for each circuit breaker Rugged metal flange handle operator Maximized flexibility of circuit breaker placement for existing and new applications Control panel can be fed from two separate supply voltages (if required) Dual mechanism allows both separate supply voltages to be controlled by a single handle to improve security features Table 17.36: Dual Cable Operating Mechanisms Selection Circuit Breaker Type GJL Table 17.37: FAL CP1 Catalog Number Frame Size (max.) $ Price 36 in. / 914 mm (2) 9422CGJD3 48 in. / 1219 mm (2) 9422CGJD4 585.00 608.00 60 in. / 1524 mm (2) 9422CGJD5 675.00 120 in. / 3048 mm (2) 9422CGJD1 36 in. / 914 mm (1) 60 in. / 1524 mm (1) 9422CGJD8 642.00 60 in. / 1524 mm (1) 120 in. / 3048 mm (1) 9422CGJD9 720.00 100 A 788.00 Special Left-hand Mounted Single Cable Operating Mechanisms Circuit Breaker Type 17-14 Cable Length in. / mm (quantity) Discount Schedule Cable Length in. / mm (quantity) Catalog Number 120 in. / 3048 mm (1) 9422CFAL10 36 in. / 914 mm (1) 9422CFAL30 60 in. / 1524 mm (1) 9422CFAL50 Frame Size (max.) $ Price 350.00 100 A 287.00 318.00 © 2012 Schneider Electric All Rights Reserved Disconnect Switch Accessories Flange Mounted, Variable Depth Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us Variable-Depth Mechanisms for Use with Square D™ Circuit Breakers and Schneider Electric™ (formerly Merlin Gerin™) Circuit Breakers Use With Circuit Breaker Frame Size No. of Poles Operating Mechanism Variable-Depth Mtg. Range Min.-Max.a (Inches) Frame Size A Operating Mechanism Only—Does Not Include Handle Mechanism Type $ Price Operating Mechanism and Handle Mechanism Includes Type A1 Handle Mechanism Type Includes Type A2 Handle Mechanism $ Price Type $ Price Square D Circuit Breakers GJL 3 100 6.00–17.75 RG1 116.00 ARG11 257.00 ARG21 FAL, FHL 2–3 100 5.38–17.75 RN1 116.00 ARN11 257.00 ARN21 372.00 KAL, KHL 2–3 250 6.38–17.88 RP1 129.00 ARP11 270.00 ARP21 386.00 LALc, LHLc, Q4L 2–3 400 7.44–18.25 RR1 329.00 ARR11 471.00 ARR21 585.00 MEL, MXL 2–3 800 9.00–18.38 RT1 449.00 ART11 593.00 ART21 705.00 MAL, MHL 2–3 1200 9.00–18.38 RT1 449.00 ART11 593.00 ART21 705.00 NAL, NCL, NEL, NXL 2–3 1200 11.00–18.37 a Class 9422 Type R2 will extend mounting depth 7 in. RX1 513.00 — Table 17.39: Class Type — 131.00 243.00 Dimensions Width (A) Height (B) Distance to Enclosure Flangea (C) Bracket Depth (D) Circuit Breaker Frame Size Type in. mm in. mm in. mm in. mm in. GJL RG1 5.00 127 4.75 121 6.00 152 17.75 451 4.00 102 FAL, FHL RN1 6.75 171 8.50 216 5.51 140 17.75 451 4.26 108 125 Minimum Maximum mm KAL, KHL RP1 7.13 181 10.13 257 6.51 165 17.88 454 4.94 LALc, LHLc, Q4L RR1 10.19 259 11.00 279 7.44 189 18.25 464 6.00 152 MEL, MXL RT1 13.38 340 14.00 356 9.00 229 18.38 467 9.69 246 MAL, MHLb RT1 13.38 340 14.00 356 9.00 229 18.38 467 9.69 246 NAL, NCL, NEL, NXL RX1 19.63 499 13.50 343 11.00 279 18.37 467 9.00 229 a b — $ Price Single Pole, Double Throw 9999 R26a Double Pole, Double Throw 9999 R27a a Not for use with the GJL operating mechanism. Table 17.40: — Electrical Interlocks—Class 9999 Description 9422R2 will extend the dimension by 7 in. Two required. Minimum mounting depth when using MAL or MHL circuit breakers can be decreased to 7.63 inches by using the Class 9422 Type RT1B conversion kit. $23.00 Warning: These operating mechanisms cannot be used with any LA / LH circuit breaker with an MB or MT suffix. c C = Distance from Outside of Flange to Circuit Breaker Mounting Surface Enclosure Door Enclosure Flange D CL R.H. Handle CL L.H. Handle A © 2012 Schneider Electric All Rights Reserved 372.00 CP1 Minimum to wall or barrier. Right- or left-hand mounting to ensure adequate wire bending space to lug surface when maximum wire size is used. Refer to NEC Article 430-10. Discount Schedule B 17-15 17 Table 17.38: NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Designed for installation in custom built control enclosures where main or branch circuit protective devices are required. All circuit breaker operating mechanisms are suitable for either right- or left-hand flange mounting, convertible on the job. Disconnect Switch Accessories Flange Mounted, Variable Depth Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us 17 Remote or Dual Adapter Kit Switch NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS or Breaker For the remote or dual operation of GJL, FAL, FHL, KAL, KHL, LAL, LHL, Q4L, MAL, MHL, MEL, and MXL circuit breakers. Remote Operation—permits mounting the Class 9422 Type A9 or A10 handle mechanism at a lower level than the disconnect device it controls. This arrangement is often required where the disconnect device is mounted too high for personnel to easily reach a conventional operator. Dual Operation—permits controlling two disconnect devices, one in line with, and one remote from, a single Class 9422 Type A9 or A10 handle mechanism. NOTE: A Class 9422 Type A9 or A10 handle (see Digest 176 page 8-15) and the preferred mounting method must be used. Table 17.41: Disconnect Device Enclosure Mounting Depth Remote operation shown (handle mechanism not included in kit) Disconnect Device Type Min. $ Price Max. Circuit Breaker GJL 10.50 19.50 FAL, FHL 10.66 19.50 KAL, KHL 11.13 19.50 LAL, LHL, Q4L 12.13 19.88 MAL, MHL,MEL, MXL 13.75 20.25 Table 17.42: D2 251.00 Air Valve Interlock Note: Air valve interlocks only accept the specific three-way air valves, manufactured by Parker, listed in the table below. Parker Valve Model Numbera Air valve interlock mounted on enclosure a Air Valve Size Knob Operated 0.50 NPT 13 M04841885 0.75 NPT 19 M04861885 M08541848 M08561848 Class 9422 Air Valve Interlock Type $ Price G1 513.00 G2 513.00 1.00 NPT M00080004 G1 513.00 25 Prices do not include air valves or handle mechanism. For more information on the air valves listed above, contact Parker at c-parker@parker.com, or call 1-800-272-7537. Table 17.43: Accessory Other Accessories Description Auxiliary kit recommended for use with 30 A and 60 A disconnect switches Channel/Flange and FAL, FCL, FHL, KAL KHL, NSF, and NSJ circuit breaker mechanisms when these devices are to be mounted on the center channel of a multi-door Support Kit enclosure or when extra rigidity for the flange is required. Supplied as Class Type $ Price 9422 C1 42.80 Channel/Flange Support Kit Alternate Mounting Kit Auxiliary Lock Plate 17-16 CP1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Reversing Drum Switches Type A and B Class 2601 / Refer to Catalog 2510CT9701 www.schneider-electric.us Class 2601 reversing drum switches may be used for across-the-line starting and reversing of AC polyphase, AC single phase or DC motors, where overload protection is not required or is provided separately. They are compact and inexpensive but ruggedly constructed. Drum switches are field convertible from maintained-only to momentary-only operation. This conversion consists of removing the handle screw and handle, turning the shaft 180 degrees, then replacing the handle and handle screw. Reversing Drum Switches 600 Vac Maximum Class 2601 Ratings NEMA Type 1 General Purpose Enclosure Maximum Horsepower Voltage Type AG2 360 Vdc Maximum NEMA Type 4 Watertight and Dusttight Enclosure NEMA Type 1 Maintained & Momentary a NEMA Type 13 Oiltight Flush Mounting $ Price Type $ Price 158.00 AF2 131.00 AC Single Phase AC PolyPhase DC Type $ Price Type $ Price Type 115200/230 230 460/575 1-1/2 — 2 — — 2 — 2 1/4 — 1/4 — AG2 158.00 AW2 428.00 AG2S2 115200/230 230 460/575 1-1/2 — 3 5 — 5 — 7-1/2 2 — 2 — BG1 428.00 BW1 590.00 — a — — 17 Table 17.44: — Maintained – “Forward”; Momentary – “Reverse”; (not field convertible) File E42243 CCN NLRV File LR25490 Class 3211-05 Approximate Dimensions—Class 2601 Reversing Drum Switches 6.89 5.58 3.38 175 142 86 3.81 97 5.50 5.20 132 3.19 2.77 3.70 81 70 94 (2) 1/2" NPT Pipe Thread 140 1.82 46 2.38 .20 2.87 (4) .17 Mounting Holes 60 Type AW2 3.20 5 73 .60 81 15 Types AW and BW Type AF2 5.38 4.00 6.62 5.18 2.68 2.91 3.26 3.53 4.61 4.86 (2) K.O. For 1/ 2" Conduits dimensions (inches) = AG/AH BG Types AG, BG Dimensions: Table 17.45: • • © 2012 Schneider Electric All Rights Reserved in. mm How to Order To Order Specify: Catalog Number Class Number Type Number Class Type 2601 AG2 CP1 Discount Schedule NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS NEMA Types 1, 3R, 4, and 13 Without Overload 17-17 Electromechanical Reduced Voltage Starters 17 NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Reduced Voltage Starting of Squirrel Cage Motors Electromechanical Reduced Voltage Starters Table 17.46: Description of All Types Class 8600 / Refer to Catalog 8600CT9601 www.schneider-electric.us A squirrel cage motor draws high starting current (inrush) and produces high starting torque when started at full voltage. While these values differ for different motor designs, for a typical NEMA design B motor, the inrush will be approximately 600% of the motor full load amperage (FLA) rating, and the starting torque will be approximately 150% of full load torque at full voltage. High current inrush and starting torque can cause problems in the electrical and mechanical systems, or may even damage the materials being processed. When a motor is started at reduced voltage, the current at the motor terminals is reduced in direct proportion to the voltage reduction, while the torque is reduced by the square of the voltage reduction. If the “typical” NEMA B motor is started at 70% of line voltage, the starting current would be 70% of the full voltage value (that is, 0.70 x 600% = 420% FLA). The torque would then be (0.70)2 or 49% of the normal starting torque (that is, 0.49 x 150% = 74% full load torque). Therefore, reduced voltage starting provides an effective means of reducing both inrush current and starting torque. If the motor has a high inertia or if the motor rating is marginal for the applied load, reducing the starting torque may prevent the motor from reaching full speed before the thermal overload relays trip. Applications that require high starting torque should be reviewed to determine if reduced voltage starting is suitable. Square D™ offers several types of electromechanical as well as solid-state reduced voltage starters that provide different starting characteristics. The following describes the 8600 series of reduced voltage starters. Class 8606—Autotransformer Starter: Autotransformer starters provide reduced voltage to the motor terminals during starting through the use of a tapped, three phase autotransformer. Taps on the autotransformer allow for selection of the motor with 50%, 65%, or 80% of line voltage values supplying 50%, 65%, or 80% of the current inrush seen during a full voltage start. The resulting starting torque will be 25%, 42%, or 64% of full voltage values, as will be the current draw on the line. Thus, the autotransformer provides the maximum torque with minimum line current. Class 8630—Wye-Delta Starter: Wye-delta starters can only be used on wye-delta motors which have six leads that allow for motor winding to be connected in either a wye or delta configuration. During start up, the windings are connected in the wye, resulting in 58% of line voltage applied across two windings. This reduces both inrush and starting torque to 33% of the delta connected values. After a set time delay, the motor leads are switched to the delta connection. The wye-delta starter is available in both open and closed transition configurations. Closed transition starters are supplied with an additional contactor and resistor bank used to keep the motor windings energized for a few cycles until the transition from wye to delta is complete. Class 8640—Part Winding Starter: Part winding starters can be used only with part winding motors. During a part winding start, only one winding is energized, reducing the inrush current to 60–70% (depending on the motor design) and starting torque to 50% of normal starting values with both windings energized. Most (but not all) dual voltage 230/460 volt motors are suitable for part winding starts at 230 volts. Starter Characteristics Characteristic Full Voltage Autotransformer, Class 8606 Wye-Delta Class, 8630 Part Winding, Class 8640 Voltage at Motor 100% 50% / 65% / 80% (tap setting) 100% 100% Ramped Up Line Current (% Full Load Current) 600% 150% / 250% / 380% 200% 390% 150% to 700% (adjustable) Starting Torque (% Rated Torque) 150% 40% / 60% / 100% 50% 70% 0% to 100% (adjustable) Start Time (Factory Setting) — 6–7 seconds 10 seconds / 15 seconds (open/closed transition) 1–1.5 seconds 10 seconds (adjustable 1–60 seconds) Advantages • • • Simple Economical High Starting Torque • • • High torque/amperage High inertial loads Flexibility • • • High inertial loads Long acceleration loads Good torque/amperage Disadvantages • • Abrupt starts Large current inrush • Large size • • Low torque No flexibility Motor Standard How to Order Note: Tables 17.47 and 17.48 are for 60 Hz; see Table 17.51 for 50 Hz codes. Table 17.47: 1. 2. 3. Standard Special Table 17.48: Coil Voltage Codes Greatest flexibility Smooth ramp Solid-state overload relay Diagnostics SCR heat dissipation Ambient limitations Standard Table 17.49: Control Code Line Control Code 208 240 380 480 600 208 240 380 480 600 V08 V03 V05 V06 V07 208 240 240 480 480 480 600 380 other 120 24 120 24 120 240 120 110/50 specify V84 V82 V80 V83 V81 V87 V86 V95 V99 17-18 • • • • • • Specify the Class Number and the Type Number. If all coils are at the line voltage, and not Sizes 6 or 7, select the voltage code from Table 17.47 (Sizes 6 and 7 are supplied with a fused transformer with 120 Vac as standard). If the coils are at a different voltage than line supply, or Size 6 or 7, select a voltage code from Table 17.48 and also select a Form code from Table 17.49 (note that a Form code may be used with any voltage code, except as noted). Line Voltage Codes 50 Hz Control Voltage Simple Small size Not suitable for: • High inertial loads • Frequent starting Special Line 380 Vac, 50 Hz Starters • • Solid-State ATS46 Table 17.50: Form Codes Form Description Fused CPT for timing relay only Fused CPT for all coils Separate control of timing relay only Separate control for all coils b c Form Code F4T F4T40 S Y195 See Table 17.50 for sizing of 380 V starters. 24 V coils are not available on Sizes 4–7. 380 Vac, 50 Hz Starters, Maxiumum Horsepower Rating Autotransformer, Class 8606 Wye-Delta, Class 8630 Part Winding, Class 8640 Max. hp NEMA Size Max. hp NEMA Size Max. hp NEMA Size — 25 50 75 150 300 — 2 3 4 5 6 15 40 75 150 250 500 1YD 2YD 3YD 4YD 5YD 6YD 15 40 75 125 250 500 1PW 2PW 3PW 4PW 5PW 6PW Table 17.51: Hz Voltage 60 50 120 110 The Class 8600 starters are available for 380 Vac, 50 Hz applications. Table 17.50 provides maximum horsepower ratings. To determine the Type Number, select the second digit based on NEMA size. Select the fifth digit based on the horsepower requirement. Specify V05 voltage code. List prices for the same NEMA size starter apply. Coil Voltages Code Voltage V02 240 220 Code Voltage V03 480 440 Code Voltage Code V06 600 550 V07 The starters in this section can also be operated at 50 Hz at the coil voltages listed in Table 17.51. For additional coil voltage availability, contact the Customer Care Center (CCC) at 1-888-778-2733. © 2012 Schneider Electric All Rights Reserved Electromechanical Reduced Voltage Starters Autotransformer Starters NOTE: Prices shown do not include thermal units. Devices require 3 thermal units (Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176 page 16-116 for selection information. Table 17.52: Motor Voltage (Starter Voltage) 3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz NEMA Type 4a Watertight and Dusttight Enclosure NEMA Type 12/3Rd Dusttight & Driptight Industrial Use Enclosure O.E.M. Kit c Open Type NEMA Size 10 2 SDG1C 8076.00 SDW1C 12491.00 SDA1C 10641.00 SDO1C 7734.00 SDK1C 6786.00 15 20 25 3 SEG1D SEG1E SEG1F 9500.00 SEW1D SEW1E SEW1F 13914.00 SEA1D SEA1E SEA1F 13707.00 SEO1D SEO1E SEO1F 8418.00 SEK1D SEK1E SEK1F 7493.00 30 40 4 SFG1G SFG1H 18417.00 SFW1G SFW1H 26535.00 SFA1G SFA1H 21834.00 SFO1G SFO1H 16848.00 SFK1G SFK1H 13181.00 23223.00 Typeb 200 (208) 50 75 230 (240) $ Price Typeb $ Price Typeb $ Price Typeb $ Price Typeb $ Price 5 SGG1J SGG1L 30330.00 SGW1J SGW1L 38448.00 SGA1J SGA1L 34176.00 SGO1J SGO1L 27167.00 SGK1J SGK1L 100 125 150 6 SHG1M SHG1N SHG1P 56507.00 SHW1M SHW1N SHW1P 67190.00 SHA1M SHA1N SHA1P 61848.00 SHO1M SHO1N SHO1P 51438.00 SHK1M SHK1N SHK1P 41481.00 10 15 2 SDG1C SDG1D 8076.00 SDW1C SDW1D 12491.00 SDA1C SDA1D 10641.00 SDO1C SDO1D 7734.00 SDK1C SDK1D 6786.00 20 25 30 3 SEG1E SEG1F SEG1G 9500.00 SEW1E SEW1F SEW1G 13914.00 SEA1E SEA1F SEA1G 12207.00 SEO1E SEO1F SEO1G 8418.00 SEK1E SEK1F SEK1G 7493.00 40 50 4 SFG1H SFG1J 18417.00 SFW1H SFW1J 26535.00 SFA1H SFA1J 21834.00 SFO1H SFO1J 16848.00 SFK1H SFK1J 13181.00 27167.00 SGK1L SGK1M 23223.00 51438.00 SHK1N SHK1P SHK1Q 41481.00 75 100 460 (480) / 575 (600) a b c d NEMA Type 1 General Purpose Enclosure Max. HP 5 SGG1L SGG1M 30330.00 SGW1L SGW1M 38448.00 SGA1L SGA1M 34176.00 SGO1L SGO1M 125 150 200 6 SHG1N SHG1P SHG1Q 56507.00 SHW1N SHW1P SHW1Q 67190.00 SHA1N SHA1P SHA1Q 61848.00 SHO1N SHO1P SHO1Q 250 300 7 SJG1R SJG1S 96786.00 SJW1R SJW1S 107468.00 SJA1R SJA1S 102126.00 — 10 15 20 25 2 SDG1C SDG1D SDG1E SDG1F 8076.00 SDW1C SDW1D SDW1E SDW1F 12491.00 SDA1C SDA1D SDA1E SDA1F 10641.00 SDO1C SDO1D SDO1E SDO1F 30 40 50 3 SEG1G SEG1H SEG1J 9500.00 SEW1G SEW1H SEW1J 13914.00 SEA1G SEA1H SEA1J 12207.00 60 75 100 4 SFG1K SFG1L SFG1M 18417.00 SFW1K SFW1L SFW1M 26535.00 SFA1K SFA1L SFA1M 125 150 200 5 SGG1N SGG1P SGG1Q 30330.00 SGW1N SGW1P SGW1Q 38448.00 250 300 400 6 SHG1R SHG1S SHG1T 56507.00 SHW1R SHW1S SHW1T 500 600 7 SJG1U SJG1W 96786.00 SJW1U SJW1W — — — 7734.00 SDK1C SDK1D SDK1E SDK1F 6786.00 SEO1G SEO1H SEO1J 8418.00 SEK1G SEK1H SEK1J 7493.00 21834.00 SFO1K SFO1L SFO1M 16848.00 SFK1K SFK1L SFK1M 13181.00 SGA1N SGA1P SGA1Q 34176.00 SGO1N SGO1P SGO1Q 27167.00 SGK1N SGK1P SGK1Q 23223.00 67190.00 SHA1R SHA1S SHA1T 61848.00 SHO1R SHO1S SHO1T 51438.00 SHK1R SHK1S SHK1T 41481.00 107468.00 SJA1U SJA1W 102126.00 SJO1W 88250.00 — — NEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost.Specify as Form G17. See “Modifications & Forms” for price adder. Both line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering. No factory modifications (Forms) are available with O.E.M. Kit. NEMA Type 12 enclosures can be field modified for outdoor non-corrosive and non-service entrance rated applications. Note: Class 8606 starters are supplied with a NEMA style medium duty autotransformer. Medium duty service includes applications to motors which drive loads such as fans, pumps, compressors, and line shafts. NEMA Sizes 2–5: Autotransformer is rated for fifteen 15-second starts per hour. NEMA Sizes 6–7: Autotransformer is rated for three 30-second starts per hour. Contact the Customer Care Center (CCC) at 1-888-778-2733 for applications which require frequent starting or jogging, or have extremely high inertia. OL 2S L1 OL T2 OL T3 2S 100 80 65 50 0 2S L3 R 1S Motor • • • • TR 1S R Catalog Number Class Number Type Number Voltage Code Form(s)e Class Type Voltage Code Form(s) 8606 SFG1M V81 S Description: 100 hp, 480 V line, 120 V separate control, 60 Hz e TR How to Order To Order Specify: 1S R L2 Table 17.53: T1 100 80 65 50 0 R Forms need to be specified only if any of the coils are at a different voltage than line supply (V8•). See page 17-18 for a fuller explanation of how to order; this page also provides the necessary coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications. R 1S 1S 2S 2S To 2 Wire Control Separate Device (If used) Control Stop 2 Start 3 1 TR TR OL Typical Autotransformer Starter Sizes 2–5 Separate Control (Form S) © 2012 Schneider Electric All Rights Reserved CP1 Discount Schedule 17-19 17 www.schneider-electric.us NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Class 8606 / Refer to Catalog 8600CT9601 Electromechanical Reduced Voltage Starters Wye-Delta Starters (Open Transition) Class 8630 / Refer to Catalog 8600CT9601 www.schneider-electric.us 17 NOTE: Prices shown do not include thermal units. Devices require 3 thermal units (Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176 page 16-116 for selection information. NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Table 17.54: 3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz Motor Voltage (Starter Voltage) Max. HP NEMA Type 1 General Purpose Enclosure NEMA Size NEMA Type 4a Watertight and Dusttight Enclosure (Stainless Steel 1YD-4YD) NEMA Type 12/3Rd Dusttight & Driptight Industrial Use Enclosure Open Type O.E.M. Kit c Typeb $ Price Typeb $ Price Typeb $ Price Typeb $ Price Typeb 10 1YD SCG1C 4892.00 SCW1C 6602.00 SCA1C 6317.00 SCO1C 4806.00 — 15 SDG1D SDW1D SDA1D SDO1D 2YD 5790.00 7713.00 7569.00 5562.00 — 20 SDG1E SDW1E SDA1E SDO1E 25 SEG1F SEW1F SEA1F SEO1F SEK1F 30 3YD SEG1G 8424.00 SEW1G 11204.00 SEA1G 10562.00 SEO1G 7542.00 SEK1G 40 SEG1H SEW1H SEA1H SEO1H SEK1H 50 SFG1J SFW1J SFA1J SFO1J SFK1J 200 4YD 17568.00 21941.00 20417.00 15987.00 60 SFG1K SFW1K SFA1K SFO1K SFK1K (208) 75 SGG1L SGW1L SGA1L SGO1L SGK1L 100 SGG1M SGW1M SGA1M SGO1M SGK1M 5YD 31584.00 39702.00 35429.00 28422.00 125 SGG1N SGW1N SGA1N SGO1N SGK1N 150 SGG1P SGW1P SGA1P SGO1P SGK1P 200 SHG1Q SHW1Q SHA1Q SHO1Q SHK1Q 250 6YD SHG1R 67589.00 SHW1R 78272.00 SHA1R 72930.00 SHO1R 62519.00 SHK1R 300 SHG1S SHW1S SHA1S SHO1S SHK1S 10 1YD SCG1C 4892.00 SCW1C 6602.00 SCA1C 6317.00 SCO1C 4806.00 — 15 SDG1D SDW1D SDA1D SDO1D 20 2YD SDG1E 5790.00 SDW1E 7713.00 SDA1E 7569.00 SDO1E 5562.00 — 25 SDG1F SDW1F SDA1F SDO1F 30 SEG1G SEW1G SEA1G SEO1G SEK1G 40 3YD SEG1H 8424.00 SEW1H 11204.00 SEA1H 10562.00 SEO1H 7542.00 SEK1H 50 SEG1J SEW1J SEA1J SEO1J SEK1J 60 SFG1K SFW1K SFA1K SFO1K SFK1K 230 4YD 17568.00 21941.00 20417.00 15987.00 75 SFG1L SFW1L SFA1L SFO1L SFK1L (240) 100 SGG1M SGW1M SGA1M SGO1M SGK1M 125 5YD SGG1N 31584.00 SGW1N 39702.00 SGA1N 35429.00 SGO1N 28422.00 SGK1N 150 SGG1P SGW1P SGA1P SGO1P SGK1P 200 SHG1Q SHW1Q SHA1Q SHO1Q SHK1Q 250 6YD SHG1R 67589.00 SHW1R 78272.00 SHA1R 72930.00 SHO1R 62519.00 SHK1R 300 SHG1S SHW1S SHA1S SHO1S SHK1S 400 SJG1T SJW1T SJA1T SJO1T 7YD 91160.00 101843.00 96501.00 86090.00 — 500 SJG1U SJW1U SJA1U SJO1U 10 SCG1C SCW1C SCA1C SCO1C 1YD 4892.00 6602.00 6317.00 4806.00 — 15 SCG1D SCW1D SCA1D SCO1D 20 SDG1E SDW1E SDA1E SDO1E 25 SDG1F SDW1F SDA1F SDO1F 2YD 5790.00 7713.00 7569.00 5562.00 — 30 SDG1G SDW1G SDA1G SDO1G 40 SDG1H SDW1H SDA1H SDO1H SEW1J SEA1J SEO1J SEK1J 50 SEG1J SEW1K 11204.00 SEA1K 10562.00 SEO1K 7542.00 SEK1K 60 3YD SEG1K 8424.00 460 SEW1L SEA1L SEO1L SEK1L 75 SEG1L (480) 100 SFG1M SFW1M SFA1M SFO1M SFK1M / 125 4YD SFG1N 17568.00 SFW1N 21941.00 SFA1N 20417.00 SFO1N 15987.00 SFK1N 575 150 SFG1P SFW1P SFA1P SFO1P SFK1P (600) 200 SGG1Q SGW1Q SGA1Q SGO1Q SGK1Q 250 5YD SGG1R 31584.00 SGW1R 39702.00 SGA1R 35429.00 SGO1R 28422.00 SGK1R 300 SGG1S SGW1S SGA1S SGO1S SGK1S 400 SHG1T SHW1T SHA1T SHO1T SHK1T 500 6YD SHG1U 67589.00 SHW1U 78272.00 SHA1U 72930.00 SHO1U 62519.00 SHK1U 600 SHG1W SHW1W SHA1W SHO1W SHK1W 800 SJG1Y SJW1Y SJA1Y SJO1Y 7YD 91160.00 101843.00 96501.00 86090.00 — 1000 SJG1Z SJW1Z SJA1Z SJO1Z a NEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost. Specify as Form G17. See page 17-32 for price adder. b Both line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering. c No Factory Modifications (Forms) available with O.E.M. Kit. d NEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information. L1 L2 L3 1M OL T1 1M OL T2 1M OL T3 Table 17.55: T2 Motor T1 T5 2M T5 2M S T4 2M S T6 TR TR 2M S 1M T6 T3 • • • • 6596.00 9300.00 18530.00 39347.00 — — 6596.00 9300.00 18530.00 39347.00 — — — 6596.00 9300.00 18530.00 39347.00 — Catalog Number Class Number Type Number Voltage Code Form(s)e e — How to Order To Order Specify: T4 $ Price — Class Type Voltage Code 8630 SFG1M V06 Form(s) Description: 100 hp, 480 V line, 480 V common control, 60 Hz Forms need to be specified only if any of the coils are at a different voltage than line supply (V8•). See page 17-18 for a fuller explanation of how to order; this page also provides the necessary coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications. Refer to page 17-32 for other factory modifications (Forms). S 1M S 2 Wire Control Device (If used) Start 1 Stop 2 3 2M TR OL TR Typical Wye-Delta Starter Sizes 1–4 (Open Transition) Common Control (Standard) 17-20 CP1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Electromechanical Reduced Voltage Starters Wye-Delta Starters (Closed Transition) NOTE: Prices shown do not include thermal units. Devices require 3 thermal units (Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176 page 16-116 for selection information. Motor Voltage (Starter Voltage) 3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz Max. HP NEMA Type 4d Watertight and Dusttight Enclosure (Stainless Steel 1YD-4YD) NEMA Type 1 General Purpose Enclosure NEMA Size NEMA Type 12/3Rc Dusttight & Driptight Industrial Use Enclosure Open Type O.E.M. Kit b Typea $ Price Typea $ Price Typea $ Price Typea $ Price Typea 10 1YD SCG2C 7470.00 SCW2C 9180.00 SCA2C 8895.00 SCO2C 7385.00 — 15 SDG2D SDW2D SDA2D SDO2D 2YD 8454.00 10376.00 10233.00 8226.00 — 20 SDG2E SDW2E SDA2E SDO2E 25 SEG2F SEW2F SEA2F SEO2F SEK2F 30 3YD SEG2G 11672.00 SEW2G 14450.00 SEA2G 13809.00 SEO2G 10790.00 SEK2G 40 SEG2H SEW2H SEA2H SEO2H SEK2H 50 SFG2J SFW2J SFA2J SFO2J SFK2J 200 4YD 22995.00 27368.00 25844.00 21414.00 60 SFG2K SFW2K SFA2K SFO2K SFK2K (208) 75 SGG2L SGW2L SGA2L SGO2L SGK2L 100 SGG2M SGW2M SGA2M SGO2M SGK2M 5YD 38363.00 46481.00 42209.00 35202.00 125 SGG2N SGW2N SGA2N SGO2N SGK2N 150 SGG2P SGW2P SGA2P SGO2P SGK2P 200 SHG2Q SHW2Q SHA2Q SHO2Q SHK2Q 250 6YD SHG2R 85022.00 SHW2R 95702.00 SHA2R 90363.00 SHO2R 79950.00 SHK2R 300 SHG2S SHW2S SHA2S SHO2S SHK2S 10 1YD SCG2C 7470.00 SCW2C 9180.00 SCA2C 8895.00 SCO2C 7385.00 — 15 SDG2D SDW2D SDA2D SDO2D — 20 2YD SDG2E 8454.00 SDW2E 10376.00 SDA2E 10233.00 SDO2E 8226.00 — 25 SDG2F SDW2F SDA2F SDO2F — 30 SEG2G SEW2G SEA2G SEO2G SEK2G 40 3YD SEG2H 11672.00 SEW2H 14450.00 SEA2H 13809.00 SEO2H 10790.00 SEK2H 50 SEG2J SEW2J SEA2J SEO2J SEK2J 60 SFG2K SFW2K SFA2K SFO2K SFK2K 230 4YD 22995.00 27368.00 25844.00 21414.00 75 SFG2L SFW2L SFA2L SFO2L SFK2L (240) 100 SGG2M SGW2M SGA2M SGO2M SGK2M 125 5YD SGG2N 38363.00 SGW2N 46481.00 SGA2N 42209.00 SGO2N 35202.00 SGK2N 150 SGG2P SGW2P SGA2P SGO2P SGK2P 200 SHG2Q SHW2Q SHA2Q SHO2Q SHK2Q 250 6YD SHG2R 85022.00 SHW2R 95702.00 SHA2R 90363.00 SHO2R 79950.00 SHK2R 300 SHG2S SHW2S SHA2S SHO2S SHK2S 400 SJG2T SJW2T SJA2T SJO2T — 7YD 118206.00 128888.00 123548.00 113135.00 500 SJG2U SJW2U SJA2U SJO2U — 10 SCG2C SCW2C SCA2C SCO2C — 1YD 7470.00 9180.00 8895.00 7385.00 15 SCG2D SCW2D SCA2D SCO2D — 20 SDG2E SDW2E SDA2E SDO2E — 25 SDG2F SDW2F SDA2F SDO2F — 2YD 8454.00 10376.00 10233.00 8226.00 30 SDG2G SDW2G SDA2G SDO2G — 40 SDG2H SDW2H SDA2H SDO2H — 50 SEG2J SEW2J SEA2J SEO2J SEK2J 60 3YD SEG2K 11672.00 SEW2K 14450.00 SEA2K 13809.00 SEO2K 10790.00 SEK2K 460 75 SEG2L SEW2L SEA2L SEO2L SEK2L (480) 100 SFG2M SFW2M SFA2M SFO2M SFK2M / 125 4YD SFG2N 22995.00 SFW2N 27368.00 SFA2N 25844.00 SFO2N 21414.00 SFK2N 575 150 SFG2P SFW2P SFA2P SFO2P SFK2P (600) 200 SGG2Q SGW2Q SGA2Q SGO2Q SGK2Q 250 5YD SGG2R 38363.00 SGW2R 46481.00 SGA2R 42209.00 SGO2R 35202.00 SGK2R 300 SGG2S SGW2S SGA2S SGO2S SGK2S 400 SHG2T SHW2T SHA2T SHO2T SHK2T 500 6YD SHG2U 85022.00 SHW2U 95702.00 SHA2U 90363.00 SHO2U 79950.00 SHK2U 700 SHG2W SHW2W SHA2W SHO2W SHK2W 800 SJG2Y SJW2Y SJA2Y SJO2Y — 7YD 118206.00 128888.00 123548.00 113135.00 1000 SJG2Z SJW2Z SJA2Z SJO2Z — a Both line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering. b No Factory Modifications (Forms) available with O.E.M. Kit. c NEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information. d NEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost. Specify as Form G17. See page 17-32 for price adder. 1M L1 OL OL 1M L2 1M L3 2 Wire Control Device (If used) T2 T4 T2 T3 Motor R E S R E S T1 T5 R E S T6 2M 1S T4 2M 1S T5 T6 • • • • e (HI) PRI PT (X1) SEC (X2) GND (If used) Start OL 3 1 Stop 2 10142.00 13931.00 25181.00 50319.00 — — 10142.00 13931.00 25181.00 50319.00 — — — 10142.00 13931.00 25181.00 50319.00 — Catalog Number Class Number Type Number Voltage Code Form(s)e T3 — How to Order To Order Specify: 2S 2S 2M OL 2S Table 17.57: T1 $ Price — 17 Table 17.56: Class Type Voltage Code Form(s) 8630 SFG1M V81 F4T40 Description: 100 hp, 480 V line, 120 V separate control, 60 Hz Forms need to be specified only if any of the coils are at a different voltage than line supply (V8 •). See page 17-18 for a fuller explanation of how to order; this page also provides the necessary coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications. Refer to page 17-32 for other factory modifications (Forms). TR 2S TR TR 2M 1S 1M TR 1S 2S 1M 1S 2M Typical Wye-Delta Starter Sizes 1–4 (Closed Transition) Fused Control Transformer (Form F4T40) © 2012 Schneider Electric All Rights Reserved CP1 Discount Schedule NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Class 8630 / Refer to Catalog 8600CT9601 www.schneider-electric.us 17-21 Electromechanical Reduced Voltage Starters Part Winding Starters Class 8640 / Refer to Catalog 8600CT9601 www.schneider-electric.us 17 NOTE: Prices shown do not include thermal units. Devices require 6 thermal units (Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176 page 16-116 for selection information. NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Table 17.58: Motor Voltage (Starter Voltage) 3-Pole Polyphase—600 Vac Maximum—50–60 Hz Max. HP Typeb a b c d Typeb $ Price Typeb O.E.M. Kit c Open Type $ Price Typeb $ Price Typeb $ Price 1PW SCG1C 3119.00 SCW1C 4829.00 SCA1C 4544.00 SCO1C 3033.00 — 15 20 2PW SDG1D SDG1E 4445.00 SDW1D SDW1E 6368.00 SDA1D SDA1E 6224.00 SDO1D SDO1E 4217.00 SDK1D SDK1E 2685.00 25 30 40 3PW SEG1F SEG1G SEG1H 6267.00 SEW1F SEW1G SEW1H 9045.00 SEA1F SEA1G SEA1H 8405.00 SEO1F SEO1G SEO1H 5868.00 SEK1F SEK1G SEK1H 4359.00 50 60 75 4PW SFG1J SFG1K SFG1L 13404.00 SFW1J SFW1K SFW1L 17775.00 SFA1J SFA1K SFA1L 16253.00 SFO1J SFO1K SFO1L 12662.00 SFK1J SFK1K SFK1L 8217.00 100 125 150 5PW SGG1M SGG1N SGG1P 28071.00 SGW1M SGW1N SGW1P 36192.00 SGA1M SGA1N SGA1P 31919.00 SGO1M SGO1N SGO1P 26505.00 SGK1M SGK1N SGK1P 18621.00 10 — 1PW SCG1C 3119.00 SCW1C 4829.00 SCA1C 4544.00 SCO1C 3033.00 — 15 20 25 2PW SDG1D SDG1E SDG1F 4445.00 SDW1D SDW1E SDW1F 6368.00 SDA1D SDA1E SDA1F 6224.00 SDO1D SDO1E SDO1F 4217.00 SDK1D SDK1E SDK1F 2685.00 30 40 50 3PW SEG1G SEG1H SEG1J 6267.00 SEW1G SEW1H SEW1J 9045.00 SEA1G SEA1H SEA1J 8405.00 SEO1G SEO1H SEO1J 5868.00 SEK1G SEK1H SEK1J 4359.00 60 75 4PW SFG1K SFG1L 13404.00 SFW1K SFW1L 17775.00 SFA1K SFA1L 16253.00 SFO1K SFO1L 12662.00 SFK1K SFK1L 8217.00 100 125 150 5PW SGG1M SGG1N SGG1P 28071.00 SGW1M SGW1N SGW1P 36192.00 SGA1M SGA1N SGA1P 31919.00 SGO1M SGO1N SGO1P 26505.00 SGK1M SGK1N SGK1P 18621.00 200 250 300 6PW SHG1Q SHG1R SHG1S 58694.00 SHW1Q SHW1R SHW1S 67338.00 SHA1Q SHA1R SHA1S 65816.00 SHO1Q SHO1R SHO1S 53622.00 — — 400 7PW SJG1T 89672.00 SJW1T 98865.00 SJA1T 98217.00 SJO1T 80699.00 — — 10 15 1PW SCG1C SCG1D 3119.00 SCW1C SCW1D 4829.00 SCA1C SCA1D 4544.00 SCO1C SCO1D 3033.00 — — — 20 25 30 40 2PW SDG1E SDG1F SDG1G SDG1H 4445.00 SDW1E SDW1F SDW1G SDW1H 6368.00 SDA1E SDA1F SDA1G SDA1H 6224.00 SDO1E SDO1F SDO1G SDO1H 4217.00 SDK1E SDK1F SDK1G SDK1H 2685.00 50 60 75 3PW SEG1J SEG1K SEG1L 6267.00 SEW1J SEW1K SEW1L 9045.00 SEA1J SEA1K SEA1L 8405.00 SEO1J SEO1K SEO1L 5868.00 SEK1J SEK1K SEK1L 4359.00 100 125 150 4PW SFG1M SFG1N SFG1P 13404.00 SFW1M SFW1N SFW1P 17775.00 SFA1M SFA1N SFA1P 16253.00 SFO1M SFO1N SFO1P 12662.00 SFK1M SFK1N SFK1P 8217.00 200 250 350 5PW SGG1Q SGG1R SGG1S 28071.00 SGW1Q SGW1R SGW1S 36192.00 SGA1Q SGA1R SGA1S 31919.00 SGO1Q SGO1R SGO1S 26505.00 SGK1Q SGK1R SGK1S 18621.00 400 500 600 6PW SHG1T SHG1U SHG1W 58694.00 SHW1T SHW1U SHW1W 67338.00 SHA1T SHA1U SHA1W 65816.00 SHO1T SHO1U SHO1W 53622.00 — — 700 800 7PW SJG1X SJG1Y 89672.00 SJW1X SJW1Y 98865.00 SJA1X SJA1Y 98217.00 SJO1X SJO1Y 80699.00 — — — 230 (240) 460 (480) / 575 (600) $ Price NEMA Type 12/3Rd Dusttight & Driptight Industrial Use Enclosure 10 200 (208) 460 (480) / 575 (600) NEMA Type 4a Watertight and Dusttight Enclosure (Stainless Steel 1PW–4PW) NEMA Type 1 General Purpose Enclosure NEMA Size — NEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost. Specifiy as Form G17. See page 17-32 for price adder. Both line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering. No Factory Modifications (Forms) available with O.E.M. Kit. NEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information. Table 17.59: L1 L2 L3 S OL2 S OL2 S OL2 S OL1 R OL1 R OL1 TR Stop 2 Start B C To Motor • • • • E F Catalog Number Class Number Type Number Voltage Code Form(s)e e Class Type Voltage Code Form(s) 8640 SFG1M V06 C Description: 100 hp, 480 V line, 480 V common control, 60 Hz Forms need to be specified only if any of the coils are at a different voltage than line supply (V8•). See page 17-18 for a fuller explanation of how to order; this page also provides the necessary coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications. Refer to page 17-32 for other factory modifications (Forms). S 2 Wire Control Device (If used) 1 To Order Specify: A D How to Order TR 3 S R TR OL1 OL2 TR Typical Part Winding Sizes 1–4 Common Control (Standard) 17-22 CP1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Electromechanical Reduced Voltage Starters Approximate Dimensions Class 8606, 8630, 8640 / Refer to Catalog 8600CT9601 www.schneider-electric.us Approximate Dimensions—Not for Construction Class 8606—Autotransformer NEMA Type 1 / 12 Enclosure NEMA Size 2 3 or 4 5 Class 8606 Autotransformer 6 Table 17.61: NEMA Size 1YD or 2YD 3YD or 4YD 5YD or 6YD Class 8630 Wye-Delta Table 17.62: NEMA Size 1YD or 2YD 3YD or 4YD 5YD or 6YD Table 17.63: Open Dim. H W D H W D H W D H W D in. mm 43 22 8 63 28 9 63 28 9 56 30 14 1092 559 203 1600 711 229 1600 711 229 1422 762 354 Non-Combo or Combo with Circuit Breaker in. mm 52 25 10 70b 32 16 70b 32 16 90b 34 20 1320 635 254 1778 813 406 1778 813 406 2286 864 508 NEMA Type 4 Enclosure Combo with Disconnect Switch in. mm 52 25 10 70b 32 16 90b 36 16 90b 64 24 1320 635 254 1778 813 406 2286 914 406 2286 1626 610 Non-Combo or Combo with Circuit Breaker in. mm 52 25 10 75b 32 16 75b 32 16 98b 34 20 1320 635 254 1778 813 406 1778 813 406 2489 864 508 Combo with Disconnect Switch in. mm 52 25 10 75b 32 16 95b 36 16 98b 64 24 1320 635 254 1778 813 406 2413 914 406 2489 1626 610 Class 8630—Wye-Delta, Open Transition NEMA Type 1 / 12 Enclosure Open Dim. Non-Combo NEMA Type 4 Enclosure Combo Non-Combo Combo in. mm in. mm in. mm in. mm in. mm H W D H W D H 21 21 7 42 25 7 62 553 553 178 1067 635 178 1576 25 23 8 48 28 8 90b 635 584 203 1219 712 203 2286 25 23 8 49 30 11 90b 635 584 203 1245 762 279 2286 25 23 8 48 28 8 98b 635 584 203 1219 712 203 2489 — — — 49 30 11 98b — — — 1245 762 279 2489 W D 29 10 737 254 36 16 914 406 36 16 914 406 36 16 914 406 36 16 914 406 Class 8630—Wye-Delta, Closed Transition NEMA Type 1 / 12 Enclosure Open Dim. H W D H W D H W D Non-Combo NEMA Type 4 Enclosure Combo Non-Combo Combo in. mm in. mm in. mm in. mm in. mm 21 21 14 42 25 14 80 30 12 553 553 354 1067 635 354 2032 762 305 25 23 16 48 28 16 90b 36 16 635 584 406 1219 712 406 2286 914 406 25 23 16 49 30 18 90b 36 16 635 584 406 1245 762 457 2286 914 406 25 23 16 48 28 16 98b 36 16 635 584 406 1219 712 406 2489 914 406 — — — 49 30 18 98b 36 16 — — — 1245 762 457 2489 914 406 Class 8640—Part Winding Enclosed—NEMA Type 1 / 4 / 12 NEMA Size 1PW or 2PW 3PW 4PW Class 8640 Part Winding 5PW 6PW a b Open Dim. H W D H W D H W D H W D H W D Non-Combo Combo with Circuit Breaker in. mm in. mm in. mm 21 21 6 42 26 7 42 26 7 35 22 10 49 24 11 553 553 152 1067 660 178 1067 660 178 889 559 254 1245 610 279 25 23 8 48 28 8 48 28 8 44 24 12 64 28 16 635 584 203 1219 712 203 1219 712 203 1118 610 305 1626 712 406 34 19 11 44 30 12 44 30 12 78ba 36 16 — — — 853 483 279 1118 762 305 1118 762 305 1981 914 406 — — — Subtract 8 in. from height for Type 1 or 12 enclosure. Free standing enclosure. Combo with Disconnect Switch in. mm 25 23 8 52 25 11 78b 32 16 78ba 36 16 90b 64 24 635 584 203 1321 635 279 1981 813 406 1981 914 406 2286 1626 406 Combination Starter Form Reference Circuit Breaker: Y791, Y7911 Nonfusible Disconnect Switch: Y792, Y7910 Fusible Disconnect Switch: Y793-Y799 Refer to page 17-32 for a complete listing of Forms for combination devices. © 2012 Schneider Electric All Rights Reserved 17-23 17 Table 17.60: NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Note: H = Height, W = Width, D = Depth Multispeed Magnetic Starters Application Data Class 8810 / Refer to Catalog 8502CT9701 17 Multispeed motors are available in two basic versions: 1) separate winding, and 2) consequent pole. A separate winding motor has a winding for each speed while a consequent pole motor has a winding for every two speeds (three-speed motors have two windings). The motor connections (and thus the types of controllers) for two speed starters are exemplified by the schematic diagrams shown below. Note that consequent pole two-speed controllers involve a 5-pole and a 3-pole starter, while separate winding controllers have two 3-pole starters. Verify the type of motor before ordering. Field modification of starters to match the motor may not be possible. Separate winding motors are usually chosen when flexibility is important, since the speeds of a consequent pole motor are usually limited to a 2/1 ratio; a broad range of speeds can be obtained on a separate winding motor. NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Table 17.65: Table 17.64: Typical Applications Constant HP Constant Torque Variable Torque A. Spindles B. Cutting Tools 1. Lathes 2. Saws A. Conveyors B. Mills C. Dough Mixers D. Reciprocating Pumps A. Fans B. Centrifugal Pumps Typical Schematic Diagrams HIGH 4 1 STOP LOW L 5 H OL OL HIGH 4 1 STOP LOW L H L1 L2 L3 L2 L3 L OL OL OL HIGH 4 1 STOP H H OL OL L H H T2 T3 T6 L OL L OL OL H H H H L2 L3 H L OL OL OL T2 T3 T6 T4 L L OL OL 1 STOP HIGH 4 L HIGH 3 L H LOW 5 H L OL OL 1 STOP HIGH 4 L H 2 HIGH 3 L H H ON L H 17-24 L T2 T3 H H H OL OL OL T11 T12 T13 2-Speed Separate Winding Constant HP, Constant Torque and Variable Torque NEMA Size 0–4 Sizes 5, 6, & 7 Use Special Circuitry The stop button must be pressed before it is possible to change from a higher to a lower speed. (Not available with Form R1.) Form R3 Decelerating Relay/Timer. This is similar in action to Form R2 accelerating relays, except that they function to prevent immediate transfer from a higher to a lower speed. A definite time interval, preset on the timer, must elapse between each speed change. Form R10 Antiplugging Relays/Timers. This Form imposes a time delay when transferring from the forward to the reverse direction or reverse to forward, for reversing multispeed starters. This provides up to a 60 second delay in the transfer of the direction of the motor, and can help prevent damage which could result from plugging. Form Y81 (Low Speed) Overload Relay Modification. For NEMA size 3 and 4, when the low speed full load current does not appear on the appropriate thermal unit selection tables, include Form Y81 (low speed) (no charge for this Form). This Form modifies the overload relay block to accept Type B thermal units. For assistance on thermal unit selection, contact the Customer Care Center (CCC) at 1-888-778-2733. Special Pilot Lighting HIGH 4 LOW 5 H 2 L OL OL OL 2-Speed Consequent Pole Constant or Variable Torque NEMA Size 0–4 Sizes 5, 6, & 7 Use Special Circuitry General. Some applications require special relays to control the speed change and/or starting of the motor. The descriptions that follow cover the four common relay schemes for these applications. Form R1 Compelling Relay. This relay requires the motor to be started at low speed before any higher speed can be selected. This arrangement ensures that the motor will always start the load at low speed. The stop button must be pressed before it is possible to change from a higher to a lower speed. (Not available with Form R2.) Form R2 Accelerating Relay/Timer. With Form R2 accelerating relays, the ultimate speed is determined by the button which is pressed, but the starter will start the motor at low speed and automatically accelerate it through successive steps until the selected speed is reached. Definite time intervals must elapse between each speed change. Individual adjustable timing relays are provided for each interval. L H T5 Additional Features—Special Relays for Non-Reversing and Reversing Multispeed Starters Table 17.66: HIGH L 3 OLOL H L OL T1 T5 2-Speed Consequent Pole Constant Horsepower NEMA Size 0–4 Sizes 5, 6, & 7 Use Special Circuitry L L1 L T4 H 5 2 T1 T1 LOW H L1 L OL OL L HIGH 3 L 2 H L L 5 H L HIGH 3 L 2 1 STOP www.schneider-electric.us Both separate winding and consequent pole motors are available in three types: 1) constant horsepower, 2) constant torque, and 3) variable torque. Table 17.64 shows typical applications for these different types of motors. NOTE: For detailed information involving the technical aspects of flexibility of the starters used in the multispeed controllers, see Classes 8702, 8736, and 8810 application data. H 2 LOW 5 H L L H HIGH 3 L H H OFF 1 STOP HIGH 4 OL OL LOW L 5 H L 1 STOP L 2 L H L HIGH 3 L H H OL OL HIGH 4 LOW 5 H L H 2 ON OFF HIGH 3 L L OL OL H H H L H OFF To Power Circuit To Power Circuit To Power Circuit To Power Circuit To Power Circuit One pilot light “On” One pilot light “Off” Two pilot lights “L” and “H'” Two pilot lights “On” and “Off” Three pilot lights “L”, “H”, and “Off” “L”, “H” and “Off” © 2012 Schneider Electric All Rights Reserved Multispeed Magnetic Starters Application Data Multispeed motors are available in two basic versions: 1) consequent pole, and 2) separate winding. A separate winding motor has a winding for each speed while a consequent pole motor has a winding for every two speeds (three-speed motors have two windings). 3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz Note that the prices shown do not include thermal units. Devices require 6 thermal units (Sizes 0–6). Standard trip thermal units are $21.50 each. See Digest 176 page 16-116 for selection information. Table 17.67: Class 8810—Non-Combination Type Maximum Polyphase Horsepower Ratings Type of Motor Constant Horsepower Motors NEMA Size 200 V Constant HP Constant Torque or Variable Torque Constant HP b Constant Torque or Variable Torque b Constant Torque or Variable Torque Constant HP b Constant Torque or Variable Torque b 460– 575 V 200 V 0 1 2 3 4 5 6 0 1 2 3 4 5 6 2 5 7-1/2 20 30 60 100 — — — — — — — 2 5 10 25 40 75 150 — — — — — — — 3 7-1/2 20 40 75 150 300 — — — — — — — — — — — — — — 3 7-1/2 10 25 40 75 150 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 2 5 7-1/2 20 30 60 100 — — — — — — — — — 2 5 10 25 40 75 150 225 — — — — — — — — 3 7-1/2 20 40 75 150 300 450 — — — — — — — — — — — — — — — — 3 7-1/2 10 25 40 75 150 — Table 17.68: Constant HP 230 V NEMA Type 1 General Purpose Enclosure Constant Torque or Variable Torque Motors 230 V 460– 575 V Type $ Price NEMA Type 4 & 4X Watertight and Dusttight Enclosure (Stainless Steel) (304) (Sizes 0—5) Sheet Steel (Size 6) Type $ Price Single Winding (Consequent Pole) 5-Pole–3-Pole — — SBG1c 2199. SBW1c 3567. — — SCG1c 2370. SCW1c 3708. — — SDG1c 4307. SDW1c 5958. — — SEG1c 6501. SEW1c 8837. — — SFG1c 17352. SFW1c 22365. — — SGG1c 34286. SGW1c 46008. — — SHG1c 77286. SHW1c 93308. 3 5 SBG2c 2199. SBW2c 3567. 7-1/2 10 SCG2c 2370. SCW2c 3708. 15 25 SDG2c 4307. SDW2c 5958. 30 50 SEG2c 6501. SEW2c 8837. 50 100 SFG2c 17352. SFW2c 22365. 100 200 SGG2c 34286. SGW2c 46008. 200 400 SHG2c 77286. SHW2c 93308. Two Winding (Separate Winding) 3-Pole–3-Poleb — — SBG3c 1571. SBW3c 2939. — — SCG3c 1772. SCW3c 3110. — — SDG3c 3167. SDW3c 3231. — — SEG3c 4962. SEW3c 7412. — — SFG3c 12168. SFW3c 17181. — — SGG3c 28718. SGW3c 40440. — — SHG3c 58755. SHW3c 66090. — — SJG3c 76032. — — 3 5 SBG4c 1571. SBW4c 2939. 7-1/2 10 SCG4c 1772. SCW4c 3110. 15 25 SDG4c 3167. SDW4c 3231. 30 50 SEG4c 4962. SEW4c 7412. 50 100 SFG4c 12168. SFW4c 17181. 100 200 SGG4c 28718. SGW4c 40440. 200 400 SHG4c 58755. SHW4c 66090. 300 600 SJG4c 76032. — — NEMA Type 4Xd Watertight, Dusttight and Corrosion Resistant Enclosure NEMA Type 12/3Rf Dusttight and Driptight Industrial Use Enclosure Open Type Type $ Price Type $ Price Type $ Price SBW51c SCW51c SDW51c — — — — SBW52c SCW52c SDW52c — — — — 4100. 4278. 6557. — — — — 4100. 4278. 6557. — — — — SBA1c SCA1c SDA1c SEA1c SFA1c SGA1c SHA1c SBA2c SCA2c SDA2c SEA2c SFA2c SGA2c SHA2c 2640. 2811. 4932. 7925. 20172. 46008. 83753. 2640. 2811. 4932. 7925. 20172. 46008. 83753. SBO1c SCO1c SDO1c SEO1c SFO1c SGO1c SHO1c SBO2c SCO2c SDO2c SEO2c SFO2c SGO2c SHO2c 2142. 2285. 4050. 6101. 15786. 31197. 70799. 2142. 2285. 4050. 6101. 15786. 31197. 70799. SBW53c SCW53c SDW53c — — — — — SBW54c SCW54c SDW54c — — — — — 3384. 3567. 3564. — — — — — 3384. 3567. 3564. — — — — — SBA3c SCA3c SDA3c SEA3c SFA3c SGA3c SHA3c SJA3c SBA4c SCA4c SDA4c SEA4c SFA4c SGA4c SHA4c SJA4c 2015. 2213. 2529. 6386. 14988. 40440. 65195. 82826. 2015. 2213. 2529. 6386. 14988. 40440. 65195. 82826. SBO3c SCO3c SDO3c SEO3c SFO3c SGO3c SHO3c SJO3c SBO4c SCO4c SDO4c SEO4c SFO4c SGO4c SHO4c SJO4c 1515. 1686. 1956. 4590. 11429. 26994. 51848. 69195. 1515. 1686. 1956. 4590. 11429. 26994. 51848. 69195. Class 8810—Combination Circuit Breaker Type (Thermal Magnetic Circuit Breakers)ae 0 1 2 3 4 5 6 0 1 2 3 4 5 6 2 5 7-1/2 20 30 60 100 — — — — — — — 2 5 10 25 40 75 150 — — — — — — — 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 2 5 7-1/2 20 30 60 100 — — — — — — — — — 2 5 10 25 40 75 150 225 — — — — — — — — a b c d e f © 2012 Schneider Electric All Rights Reserved Single Winding (Consequent Pole) 5-Pole–3-Pole — — CBG1c 4206. CBW1c 6429. CBW51c 6962. CBA1c 4676. — — — CCG1c 4377. CCW1c 6566. CCW51c 7140. CCA1c 4867. — — — CDG1c 6758. CDW1c 10089. CDW51c 10089. CDA1c 7497. — — — CEG1c 9162. CEW1c 13836. — — CEA1c 10787. — — — CFG1c 22224. CFW1c 29460. — — CFA1c 26753. — — — CGG1c 43758. CGW1c 57816. — — CGA1c 56847. — — — CHG1c 91229. CHW1c 68843. — — CHA1c 65841. — 5 CBG2c 4206. CBW2c 6429. CBW52c 6962. CBA2c 4676. — 3 10 CCG2c 4377. CCW2c 6566. CCW52c 7140. CCA2c 4867. — 7-1/2 15 25 CDG2c 6758. CDW2c 10089. CDW52c 10089. CDA2c 7497. — 30 50 CEG2c 9162. CEW2c 13836. — — CEA2c 10787. — 50 100 CFG2c 22224. CFW2c 29460. — — CFA2c 26753. — 100 200 CGG2c 43758. CGW2c 57816. — — CGA2c 56847. — 200 400 CHG2c 91229. CHW2c 68843. — — CHA2c 65841. — Two Winding (Separate Winding) 3-Pole–3-Poleb 3 — — — CBG3c 3581. CBW3c 5801. CBW53c 6251. CBA3c 4050. — 7-1/2 — — — CCG3c 3780. CCW3c 5972. CCW53c 6429. CCA3c 4248. — 20 — — — CDG3c 5616. CDW3c 8379. CDW53c 8879. CDA3c 6357. — 40 — — — CEG3c 7626. CEW3c 12297. — — CEA3c 9248. — 75 — — — CFG3c 17040. CFW3c 16182. — — CFA3c 14379. — 150 — — — CGG3c 38190. CGW3c 52248. — — CGA3c 51278. — 300 — — — CHG3c 72629. CHW3c 84306. — — CHA3c 80199. — 450 — — — CJG3c 95358. — — — — CJA3c 103217. — 3 3 5 CBG4c 3581. CBW4c 5801. CBW54c 6251. CBA4c 4050. — — 7-1/2 7-1/2 10 CCG4c 3780. CCW4c 5972. CCW54c 6429. CCA4c 4248. — — 10 15 25 CDG4c 5616. CDW4c 8379. CDW54c 8879. CDA4c 6357. — — 25 30 50 CEG4c 7626. CEW4c 12297. — — CEA4c 9248. — — 40 50 100 CFG4c 17040. CFW4c 16182. — — CFA4c 14379. — — 75 100 200 CGG4c 38190. CGW4c 52248. — — CGA4c 51278. — — 150 200 400 CHG4c 72629. CHW4c 84306. — — CHA4c 80199. — — — 300 600 CJG4c 95358. — — — — CJA4c 103217. The NEC 1300% maximum setting for instantaneous trip circuit breakers may be inadequate for multispeed motors. Prices and type numbers shown for three phase, separate-winding motor starters apply only when motor windings are wye connected. When motor windings are connected open delta, use the prices shown for three phase consequent pole motor starters. Voltage code must be specified to order this product. Refer to standard voltage codes shown on page 17-18. NEMA Type 4X hubs are included with each starter at no additional cost. Not available in Mag-Gard versions. NEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information. 3 7-1/2 20 40 75 150 300 — — — — — — — — — — — — — — 3 7-1/2 10 25 40 75 150 CP1 Discount Schedule — — — — — — — — — — — — — — — — — — — — — — — — — — — — 17-25 17 www.schneider-electric.us NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Class 8810 / Refer to Catalog 8502CT9701 Multispeed Magnetic Starters Two-Speed Combination Starters Class 8810 / Refer to Catalog 8502CT9701 17 3-Pole Polyphase, 600 Vac Max., 50–60 Hz Note that the prices shown do not include thermal units. Devices require 6 thermal units (Sizes 0–6). NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Table 17.69: Class 8810—Combination Disconnect Switch Type (Class H Fuse Clips) Maximum Polyphase Horsepower Ratings Type of Motor Constant Horsepower Motors NEMA Size 200 V 0 1 2 Constant Horsepower 3 4 5 6 0 1 Constant Torque or Variable Torque 2 3 4 5 6 0 1 2 Constant Horsepower a 3 4 5 6 0 1 Constant Torque or Variable Torque a 2 3 4 5 6 230 V Constant Torque or Variable Torque Motors 460– 575 V 200 V 230 V Fuse Clip Size A 460– 575 V NEMA Type 4 & 4X Watertight and Dusttight Enclosure Stainless Steel (304) (Sizes 0–5) Sheet Steel (Size 6 not 4X) NEMA Type 1 General Purpose Enclosure Type $ Price Type $ Price NEMA Type 12/3Rc Dusttight and Driptight Industrial Use Enclosure Type Single Winding (Consequent Pole) 5-Pole–3-Pole None UBG1b 3537.00 UBW1b 5759.00 UBA1b 2 2 3 — — — 30d DBG1b 3765.00 DBW1b 5988.00 DBA1b None UCG1b 3708.00 UCW1b 5903.00 UCA1b 5 5 7-1/2 — — — 30d DCG1b 3936.00 DCW1b 6129.00 DCA1b None UDG1b 6015.00 UDW1b 8751.00 UDA1b 7-1/2 10 20 — — — 60 DDG1b 6129.00 DDW1b 8864.00 DDA1b None UEG1b 8666.00 UEW1b 13337.00 UEA1b 20 25 40 — — — 100 DEG1b 8837.00 DEW1b 13508.00 DEA1b None UFG1b 19517.00 UFW1b 27693.00 UFA1b 30 40 75 — — — 200 DFG1b 20970.00 DFW1b 25964.00 DFA1b None UGG1b 39644.00 UGW1b 35799.00 UGA1b 60 75 150 — — — 400 DGG1b 40154.00 DGW1b 54212.00 DGA1b None UHG1b 87789.00 UHW1b 99824.00 UHA1b 100 150 300 — — — 600 DHG1b 91085.00 DHW1b 103121.00 DHA1b None UBG2b 3537.00 UBW2b 5759.00 UBA2b — — — 3 3 5 30d DBG2b 3765.00 DBW2b 5988.00 DBA2b None UCG2b 3708.00 UCW2b 5903.00 UCA2b — — — 7-1/2 7-1/2 10 30d DCG2b 3936.00 DCW2b 6129.00 DCA2b UDW2b 8751.00 UDA2b None UDG2b 6015.00 — — — 10 15 25 DDW2b 8864.00 DDA2b 60 DDG2b 6129.00 None UEG2b 8666.00 UEW2b 13337.00 UEA2b — — — 25 30 50 100 DEG2b 8837.00 DEW2b 13508.00 DEA2b None UFG2b 19517.00 UFW2b 27693.00 UFA2b — — — 40 50 100 200 DFG2b 20970.00 DFW2b 25964.00 DFA2b None UGG2b 39644.00 UGW2b 35799.00 UGA2b — — — 75 100 200 400 DGG2b 40154.00 DGW2b 54212.00 DGA2b None UHG2b 87789.00 UHW2b 99824.00 UHA2b — — — 150 200 400 600 DHG2b 91085.00 DHW2b 103121.00 DHA2b Two Winding (Separate Winding) 3-Pole–3-Pole None UBG3b 2910.00 UBW3b 5133.00 UBA3b 2 2 3 — — — 30d DBG3b 3140.00 DBW3b 5360.00 DBA3b None UCG3b 3110.00 UCW3b 5304.00 UCA3b 5 5 7-1/2 — — — 30d DCG3b 3338.00 DCW3b 5531.00 DCA3b None UDG3b 4877.00 UDW3b 7640.00 UDA3b 7-1/2 10 20 — — — 60 DDG3b 4991.00 DDW3b 7754.00 DDA3b None UEG3b 7127.00 UEW3b 11798.00 UEA3b 20 25 40 — — — 100 DEG3b 7866.00 DEW3b 11969.00 DEA3b None UFG3b 15159.00 UFW3b 22509.00 UFA3b 30 40 75 — — — 200 DFG3b 17324.00 DFW3b 23021.00 DFA3b None UGG3b 34073.00 UGW3b 48131.00 UGA3b 60 75 150 — — — 400 DGG3b 34586.00 DGW3b 48644.00 DGA3b None UHG3b 69188.00 UHW3b 80868.00 UHA3b 100 150 300 — — — 600 DHG3b 72485.00 DHW3b 84164.00 DHA3b None UBG4b 2910.00 UBW4b 5133.00 UBA4b — — — 3 3 5 30d DBG4b 3140.00 DBW4b 5360.00 DBA4b None UCG4b 3110.00 UCW4b 5304.00 UCA4b — — — 7-1/2 7-1/2 10 30d DCG4b 3338.00 DCW4b 5531.00 DCA4b None UDG4b 4877.00 UDW4b 7640.00 UDA4b — — 10 15 25 — 60 DDG4b 4991.00 DDW4b 7754.00 DDA4b None UEG4b 7127.00 UEW4b 11798.00 UEA4b — — — 25 30 50 100 DEG4b 7866.00 DEW4b 11969.00 DEA4b None UFG4b 15159.00 UFW4b 22509.00 UFA4b — — — 40 50 100 200 DFG4b 17324.00 DFW4b 23021.00 DFA4b None UGG4b 34073.00 UGW4b 48131.00 UGA4b — — — 75 100 200 400 DGG4b 34586.00 DGW4b 48644.00 DGA4b None UHG4b 69188.00 UHW4b 80868.00 UHA4b — — — 150 200 400 600 DHG4b 72485.00 DHW4b 84164.00 DHA4b a Prices and type numbers shown for three phase, separate-winding Table 17.70: Coil Voltage Codes motor starters apply only when motor windings are wye connected. When motor windings are connected open delta, use the prices shown Voltage for three phase consequent pole motor starters. Code b Voltage code must be specified to order this product. Refer to standard 60 Hz 50 Hz voltage codes shown below. 24fe — V01 c NEMA Type 12 enclosures may be field modified for outdoor 120f 110 V02 non-corrosive and non-service entrance rated applications. See 208 — V08 Digest 176 page 16-95 for more information. 240 220 V03 d When separate control is specified, use V8x (see page 32) voltage — 380 V05 codes to specify motor and control voltages. 480 440 V06 600 550 V07 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17-28 Specify Specify V99 Refer to the following Digest 176 pages for: Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-100 Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-105 Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 17-26 www.schneider-electric.us Standard trip thermal units are $21.50 each. See Digest 176 page 16-116 for selection information. CP1 Discount Schedule $ Price 4008.00 4235.00 4179.00 4406.00 6758.00 6870.00 10287.00 10458.00 24987.00 22500.00 34622.00 52446.00 95324.00 98621.00 4008.00 4235.00 4179.00 4406.00 6758.00 6870.00 10287.00 10458.00 24987.00 22500.00 34622.00 52446.00 95324.00 98621.00 3380.00 3609.00 3581.00 3807.00 5616.00 5732.00 8751.00 9491.00 19803.00 21852.00 50439.00 50952.00 76766.00 80063.00 3380.00 3609.00 3581.00 3807.00 5616.00 5732.00 8751.00 9491.00 19803.00 21852.00 50439.00 50952.00 76766.00 80063.00 $ Price Adder No Charge No Charge No Charge No Charge No Charge No Charge No Charge 35.60 e 24 V coils are not available on Sizes 4–7. On Sizes 00–3, where 24 V coils are available, Form S (separate control) must be specified (for example, order as 8810UBG1V01S). f These voltage codes must include Form S (supplied at no charge) (for example, order as 8810UCG1V02S). Note: For voltage codes used with control transformers, see page 17-32. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. © 2012 Schneider Electric All Rights Reserved Multispeed Magnetic Starters Reversing Two-Speed Magnetic Starters Class 8810 / Refer to Catalog 8502CT9701 www.schneider-electric.us Table 17.71: Class 8810—Reversing Maximum Polyphase Ratings Type of Motor Constant Horsepower Motors NEMA Size Single Winding Constant Horsepower Single Winding Constant Torque or Variable Torque Two Winding Constanta Horsepower Two Winding Constanta Torque or Variable Torque 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 200 V 230 V 2 5 7-1/2 20 30 60 — — — — — — 2 5 7-1/2 20 30 60 — — — — — — 2 5 10 25 40 75 — — — — — — 2 5 10 25 40 75 — — — — — — Reversing In One Speed Only (Specify High or Low)b NEMA Type 1 General Purpose Enclosure Constant Torque or Variable Torque Motors 460– 575 V 3 7-1/2 20 40 75 150 — — — — — — 3 7-1/2 20 40 75 150 — — — — — — 200 V 230 V — — — — — — 3 7-1/2 10 25 40 75 — — — — — — 3 7-1/2 10 25 40 75 — — — — — — 3 7-1/2 15 30 50 100 — — — — — — 3 7-1/2 15 30 50 100 460– 575 V — — — — — — 5 10 25 50 100 200 — — — — — — 5 10 25 50 100 200 Type SBG21c SCG21c SDG21c SEG21c SFG21c SGG21c SBG22c SCG22c SDG22c SEG22c SFG22c SGG22c SBG23c SCG23c SDG23c SEG23c SFG23c SGG23c SBG24c SCG24c SDG24c SEG24c SFG24c SGG24c $ Price 3936. 4248. 6984. 10260. 20457. 46449. 3936. 4248. 6984. 10260. 20457. 46449. 3252. 3452. 5817. 9005. 15929. 37335. 3252. 3452. 5817. 9005. 15929. 37335. NEMA Type 12 Dusttight and Driptight Industrial Use Enclosure Open Type Type $ Price Type SBA21c SCA21c SDA21c SEA21c SFA21c SGA21c SBA22c SCA22c SDA22c SEA22c SFA22c SGA22c SBA23c SCA23c SDA23c SEA23c SFA23c SGA23c SBA24c SCA24c SDA24c SEA24c SFA24c SGA24c 5261. 5574. 8522. 13892. 28290. 58172. 5261. 5574. 8522. 13892. 28290. 58172. 4577. 4778. 7353. 12639. 22338. 49058. 4577. 4778. 7353. 12639. 22338. 49058. SBO21c SCO21c SDO21c SEO21c SFO21c SGO21c SBO22c SCO22c SDO22c SEO22c SFO22c SGO22c SBO23c SCO23c SDO23c SEO23c SFO23c SGO23c SBO24c SCO24c SDO24c SEO24c SFO24c SGO24c Reversing In Both Speeds NEMA Type 1 General Purpose Enclosure NEMA Type 12/3Rf Dusttight and Driptight Industrial Use Enclosure Open Type $ Price Type $ Price Type $ Price Type 3851. 4121. 6501. 9662. 19718. 42164. 3851. 4121. 6501. 9662. 19718. 42164. 3167. 3324. 5432. 8267. 15188. 33048. 3167. 3324. 5432. 8267. 15188. 33048. 4563. 4926. 8522. 13508. 26810. 56946. 4563. 4926. 8522. 13508. 26810. 56946. 4193. 4620. 8067. 12027. 21284. 49455. 4193. 4620. 8067. 12027. 21284. 49455. 6330. 6728. 10517. 17139. 33390. 68679. 6330. 6728. 10517. 17139. 33390. 68679. 5958. 6386. 10061. 15885. 27693. 59396. 5958. 6386. 10061. 15885. 27693. 59396. SBO31c SCO31c SDO31c SEO31c SFO31c SGO31c SBO32c SCO32c SDO32c SEO32c SFO32c SGO32c SBO33c SCO33c SDO33c SEO33c SFO33c SGO33c SBO34c SCO34c SDO34c SEO34c SFO34c SGO34c SBG31c SCG31c SDG31c SEG31c SFG31c SGG31c SBG32c SCG32c SDG32c SEG32c SFG32c SGG32c SBG33c SCG33c SDG33c SEG33c SFG33c SGG33c SBG34c SCG34c SDG34c SEG34c SFG34c SGG34c SBA31c SCA31c SDA31c SEA31c SFA31c SGA31c SBA32c SCA32c SDA32c SEA32c SFA32c SGA32c SBA33c SCA33c SDA33c SEA33c SFA33c SGA33c SBA34c SCA34c SDA34c SEA34c SFA34c SGA34c $ Price 4449. 4791. 8010. 11997. 24930. 52659. 4449. 4791. 8010. 11997. 24930. 52659. 4077. 4449. 7554. 11228. 20487. 43388. 4077. 4449. 7554. 11228. 20487. 43388. 3-Pole Polyphase, 600 Vac Max., 50–60 Hz Note that the prices shown do not include thermal units. Devices require 6 thermal units (Sizes 0–6). Standard trip thermal units are $21.50 each. See Digest 176 page 16-116 for selection information. Table 17.72: Type of Motor Class 8810—Non-Reversing, Vertically Arranged, Open Type, Two-Speed Starters Maximum HP Ratings NEMA Size Constant Horsepower Constant Torque or Variable Torque 200 V 0 1 2 3 4 0 1 2 3 4 a b c 230 V 380 V For Consequent Pole Motors 460-575 V Type $ Price For Separate Winding Motors Type $ Price 2 2 3 3 SBO11c 2142.00 SBO13c 1515.00 5 5 7-1/2 7-1/2 SCO11c 2282.00 SCO13c 1686.00 7-1/2 10 20 20 SDO11c 4050.00 SDO13c 2939.00 20 25 40 40 SEO11c 6101.00 SEO13c 4563.00 30 40 60 75 SFO11c 15786.00 SFO13c 11429.00 3 3 5 5 SBO12c 2142.00 SBO14c 1515.00 7-1/2 7-1/2 10 10 SCO12c 2282.00 SCO14c 1686.00 10 15 25 25 SDO12c 4050.00 SDO14c 2939.00 25 30 50 50 SEO12c 6101.00 SEO14c 4563.00 40 50 75 100 SFO12c 15786.00 SFO14c 11429.00 Prices and type numbers shown for three phase, separate winding motor starters apply only when motor windings are wye connected. When motor windings are connected open delta, use the prices shown for consequent pole motor starters. Specify the speed which requires reversing by adding an L (low) or an H (high) after the type number, e.g., a Class 8810 Type SBG21 with reversing in low only would be ordered as a Class 8810 Type SBG21L. Voltage codes must be specified to order this product. Refer to standard voltage codes listed below. Table 17.73: Coil Voltage Codes Voltage 60 Hz 50 Hz 24ed 120e 208 240 — 480 600 Specify — 110 — 220 380 440 550 Specify Code V01 V02 V08 V03 V05 V06 V07 V99 $ Price Adder No Charge No Charge No Charge No Charge No Charge No Charge No Charge 35.60 d 24 V coils are not available on Sizes 4–7. On Sizes 00–3, where 24 V coils are available, Form S (separate control) must be specified (for example, order as 8810SCG21V01S). These voltage codes must include Form S (supplied at no charge) (for example, order as 8810SDG21V02S). NEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information. Note: For voltage codes used with control transformers, see page 17-18. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. e f Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17-28 Refer to the following Digest 176 pages for: Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . page 16-100 Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . page 16-105 Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . page 16-109 © 2012 Schneider Electric All Rights Reserved CP1 Discount Schedule 17-27 17 Note that the prices shown do not include thermal units. Devices require 6 thermal units (Sizes 0–6). Standard trip thermal units are $21.50 each. See Digest 176 page 16-116 for selection information. NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS 3-Pole Polyphase, 600 Vac Max., 50–60 Hz Multispeed Magnetic Starters 17 Table 17.74: NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS SBG and SCG Two-Speed Magnetic Starters Class 8810 / Refer to Catalog 8502CT9701 NEMA Type 1 Enclosure (see Figure 1) Type A D A B C D E F G H 11-7/8 11-7/8 7-17/32 9-3/4 1-1/16 1-1/16 9-3/4 5/16 SDG 14-7/8 14-1/8 7-21/32 12-3/4 1-1/16 1-1/16 12 5/16 SEG3 & 4 and SFG3 & 4 18-5/32 29-5/32 9-15/64 15-1/2 1-11/32 1-11/32 26-1/2 7/16 SEG1 & 2 and SFG1 & 2 22-5/32 39-5/32 10-15/64 19-1/2 1-11/32 1-11/32 36-1/2 7/16 SGG1, 2, 3, 4 20-7/32 65-3/4 16-29/64 31 2-1/8 2-1/8 42 9/16 SHG1, 2, 3, 4 36-7/32 62-7/32 19-15/32 SJG3 & 4 A B D 7-13/16 4-1/4 4-3/16 19/32 8-1/4 4-1/4 5-5/16 SEW3 & 4 and SFW3 & 4 18-5/32 32-7/32 8-19/64 12 SEW1 & 2 and SFW1 & 2 22-5/32 42-7/32 9-49/64 SGW1, 2, 3, 4 12-1/8 SBW and SCW 12-5/8 14-11/16 14-7/8 15-3/4 35-7/32 49-7/32 RESET J C SDW C Floor Mount NEMA Type 4 Enclosure (see Figure 1) Type E GB RESET Consult Square D Table 17.75: www.schneider-electric.us E F Figure 1: NEMA Type 1, 4, and 12 Enclosures G H I J 13-1/2 5/16 1-21/32 2-5/16 15 5/16 2-1/32 2-5/8 3-5/64 55/64 30-1/2 7/16 2-37/64 3-3/16 16 3-5/64 55/64 40-1/2 7/16 2-21/64 2-57/64 27 4-3/32 39/64 48 9/16 2-63/64 3-1/2 3/8 I F (4) H Dia. Mtg. Holes A Table 17.76: Type A B C D E F G 11-7/8 13-1/2 7-3/4 4-1/4 3-13/16 3/8 12-3/4 5/16 14-7/8 15-3/4 7-7/8 4-1/4 5-5/16 3/8 15 5/16 SEA3 & 4 and SFA3 & 4 18-5/32 31-1/2 9-19/32 16 3-3/32 1/2 30-1/2 7/16 SEA1 & 2 and SFA1 & 2 22-5/3 41-1/2 10-19/32 16 3-3/32 1/2 40-1/2 7/16 SGA1, 2, 3, 4 35-7/32 49 13-7/64 27 4-7/64 1/2 48 9/16 SHA1, 2, 3, 4 36-7/32 62-7/32 19-15/32 I H RESET RESET Consult Square D NEMA Size 0 and 1 2 B N P L K Floor Mount Fig. No. C H SDA Table 17.77: G F SBA and SCA SJA3 & 4 E D NEMA Type 12/3R Enclosure (see Figure 1) Travel M J Figure 2: Class 8810 NEMA Sizes 0, 1, and 2 Non-Reversing, Open Type Mtg. Holes A B C D E F G H I J K L M N SBO1, 2 SCO1, 2 4 9-5/8 7-11/32 5-5/16 8 5/8 — 7/32 6-29/32 — 7/32 4-3/4 2-1/4 5-1/16 19/32 SBO3, 4 SCO3, 4 3 7-1/8 6-29/32 5-5/16 — — 3-13/32 15/32 6-7/32 — 7/32 3-9/16 1-5/8 5-1/16 19/32 SDO1, 2 6 12-1/32 8-17/32 6-1/32 10-3/8 1/2 — 1/4 8-1/8 6-1/4 5/32 5-3/4 2-13/16 5-5/32 25/32 SDO3, 4 3 9 8-1/16 6-1/32 — — 4-1/2 3/8 7-1/2 — 3/16 4-11/32 2-5/32 5-5/32 25/32 SEO1, 2 4 18 14-7/16 17 12-1/4 1-1/2 11/16 1/2 6-7/16 7-3/8 1-21/32 2-5/32 — — — SEO3, 4 4 12-3/4 12-9/32 11-3/4 10-3/4 1-1/32 1/2 1/2 2-1/2 6-3/4 1-5/32 1-5/32 — — — SFO1, 2 4 18-5/8 15-19/32 17 12-1/4 1-27/32 1-1/2 1-1/8 6-7/16 7-21/32 1-21/32 1-21/32 — — — Type 2 3 3 4 4 SFO3, 4 4 14-1/4 14-19/32 13-1/4 12-1/4 1-27/32 1/2 1/2 2-15/16 7-3/8 1-21/32 1-21/32 — — — SGO1, 2a 4 29-9/32 20-9/32 9-3/8 5-13/32 1-9/32 28 5/8 12-9/16 19 5/8 22-17/32 1/2 2-13/32 6-5/8 5 4 6b — 7c SGO3, 4 4 19-9/32 20-9/32 9-3/8 5-13/32 1-9/32 18 5/8 2-5/8 19 5/8 12-17/32 1/2 2-13/32 6-5/8 SHO1, 2a 4 29-17/32 22-7/16 9-17/32 6-31/32 3-13/16 28 3/4 11-5/8 21-3/16 5/8 9-7/8 9/16 3-1/32 9-5/16 4 19-17/32 22-7/16 9-17/32 6-31/32 3-13/16 18 3/4 21-3/16 1-11/16 5/8 9-7/8 9/16 3-1/32 9-5/16 SHO3, 4 SJO3, 4 Consult the Customer Care Center (CCC) at 1-888-778-2733. a Consequent pole type starters consist of two 3-pole starters as pictured in Figure 4 and an additional 2-pole shorting contactor (not shown), all on a common baseplate, horizontally mounted. b Current transformers used with Size 1 overload relay blocks. c Solid-state overload relays and special current transformers. A C A F E 7.00 178 .50 13 E G C .50 13 D B I B K RESET RESET J NOTE: Illustrations are intended for dimensional information only and may not represent the actual enclosure. Dimensions are shown in inches. 17-28 G H I .50 F Prov. for (4) .31 Dia. Mtg. Screws 13 8 .56 14 Reset Travel 6.25 159 Figure 3: Class 8810 NEMA Sizes 3 and 4 D H M M K M M N J (4) L Dia. Mtg. Holes Figure 4: Class 8810 NEMA Size 5 and 6 © 2012 Schneider Electric All Rights Reserved Multispeed Magnetic Starters Approximate Dimensions Class 8810 / Refer to Catalog 8502CT9701 www.schneider-electric.us NEMA Size NEMA Type 1 Enclosure, Figure 1 Dimensions (in inches)—see Figure 1 Class Top & Bottom Sides Type A B C 13-7/8 23-1/8 D E F 21 G H I J K L M N O W X Y 1-1/4 7/8 1/2–3/4–1 1/2–3/4–1 1/2 1–1-1/4 1/2–3/4 1/2 0–1 8810 CBG UBG DBG CCG UCG DCG 19-9/32 1-7/8 1-7/8 2 8810 CDG UDG DDG 15-5/32 28-29/32 9-9/16 11-5/8 26-1/4 21-13/16 2-3/16 2 4 2-5/8 3a 8810 CEG UEG DEG 22-1/8 42-5/8 2-11/32 2-1/8 4-1/4 2-5/8 1-1/4 3-19/64 2-1/4 7/8 3/4 1–1-1/4–1-1/2 1/2–3/4 1/2 4a 8810 CFG UFG DFG 22-1/8 50-1/8 10-3/16 18-5/8 47-1/2 29-3/16 2-29/32 2-11/16 5-3/8 2-5/8 1-5/16 3-19/64 2-1/4 7/8 3/4 1/2 Table 17.79: 8-1/4 10-5/8 10-1/8 18-5/8 40 29-1/8 3-3/4 2-5/16 1-1/16 3-19/64 2-3/16 1-21/64 3-19/64 2-7/32 1-17/64 29/32 2-1/2 1/2–3/4 NEMA Type 4 Enclosure, Figure 2 Dimensions (in inches)—see Figure 2 NEMA Size Class Type 0–1 8810 CBW UBW DBW CCW UCW DCW Top & Bottom Bottom A B C D E F G H I J K L W X 13-7/8 8-21/64 25-3/16 3-19/64 2-9/16 8-3/4 24 19/32 3-61/64 1-5/8 2-5/16 18-17/32 3/4 Hub 1 Hub 1-1/2 Hub 2 8810 CDW UDW DDW 15-1/8 9-37/64 30-15/16 3-19/64 2-9/16 10 29-3/4 19/32 3-61/64 2 2-5/8 21-11/32 3/4 Hub 3a 8810 CEW UEW DEW 22-1/8 10-1/8 46-1/4 3-19/64 3 16 44 5/8 3-15/16 1-3/4 2-5/8 29-1/8 3/4 Hub 2 Hub 4a 8810 CFW UFW DFW 22-1/8 10-3/16 53-3/4 3-19/64 3 16 51-1/2 5/8 3-15/16 2-9/32 3-3/16 29-3/16 3/4 Hub 2-1/2 Hub Table 17.80: NEMA Type 12 Enclosure, Figure 3 Dimensions (in inches)—see Figure 3 NEMA Size Class 0–1 8810 Type A B C D E F G H I J CBA UBA DBA CCA UCA DCA 13-7/8 10-3/32 24-3/4 3-19/64 2-9/16 8-3/4 24 3/8 3-61/64 20-9/32 23-7/16 2 8810 CDA UDA DDA 15-5/32 10-31/32 31-1/4 3-19/64 3-5/64 9 30-1/4 1/2 4-53/64 3a 8810 CEA UEA DEA 22-1/8 10-1/8 45 3-19/64 3 16 44 5/8 3-15/16 29-1/8 4a 8810 CFA UFA DFA 22-1/8 10-3/16 52-1/2 3-19/64 3 16 51-1/2 5/8 3-15/16 29-3/16 a Size 3 (5-Pole–3-Pole) with FA, KA circuit breaker or 100 A disconnect switch. Size 4 (5-Pole–3-Pole) with KA circuit breaker or 200 A disconnect switch. Size 3 & 4 (3-Pole–3-Pole) enclosures may be smaller. Consult the Customer Care Center (CCC) at 1-888-778-2733 for additional dimensional information. HANDLE SWING L A D M HANDLE SWING HANDLE SWING C A F N K D E A F B H D E B H O Y E B G C G C (4) .31 DIA. MTG.HOLES 8 (for Size 0, 1, & 2) (4) .31 DIA. MTG.HOLES 8 (for Size 0, 1, & 2) Y COVER OPEN 90° (4) .31 DIA. MTG.HOLES 8 (for Size 0, 1, & 2) COVER OPEN 90° F J L X W W W G J X J I I H I Figure 1: NEMA Type 1 Enclosure K Figure 2: NEMA Type 4 Enclosure Figure 3: NEMA Type 12 Enclosure NOTE: Illustrations are intended for dimensional information only and may not represent the actual enclosure. Dimensions are shown in inches. © 2012 Schneider Electric All Rights Reserved 17-29 17 Table 17.78: NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Disconnect Switch or Circuit Breaker Type Lighting Contactors Panelboard Lighting Contactors, Type PB Class 8903 / Refer to Catalog 8903CT9701 www.schneider-electric.us 17 General Information NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Panelboard lighting contactors, sometimes called remote control switches, are designed for use with lighting panelboards and motor control centers where either panel or bus mounting is desired. Type PB lighting contactors can be used in a retrofit or new project without increasing the panelboard depth. They can be used to directly replace many inoperative existing switches. Table 17.81: Class 8903 Type PB Lighting Contactors Description Bus Mount Panel Mount (Includes Lugs) Size (A) Poles Type 30 2 3 PBM 10Ba PBM 11Ba 2129.00 2403.00 PBM 10a PBM 11a 2640.00 2973.00 60 2 3 PBP 10Ba PBP 11Ba 2237.00 2573.00 PBP 10a PBP 11a 2762.00 3185.00 75 2 3 PBN 10Ba PBN 11Ba 2237.00 2573.00 PBN 10a PBN 11a 2762.00 3185.00 100 2 3 PBQ 10Ba PBQ 11Ba 2541.00 2978.00 PBQ 10a PBQ 11a 3119.00 3546.00 150 2 3 PBR 10Ba PBR 11Ba 3162.00 4055.00 PBR 10a PBR 11a 3897.00 4787.00 200 2 3 PBV 10Ba PBV 11Ba 3551.00 4496.00 PBV 10a PBV 11a 4409.00 5360.00 3909.00 4958.00 PBW 10a PBW 11a 4964.00 5990.00 Panel Mount File E78427 CCN NRNT The features include: mechanically held; compatible with Square D panelboards; short-circuit ratings to 100 kA; compact arc suppression; bus or panel mounted; fits in standard-depth lighting panelboards; easy manual operation; standard coil clearing contacts; and operates in any position. $ Price 2 PBW 10Ba 3 PBW 11Ba Voltage code must be specified to order this product. Refer to standard voltage codes listed below. 225 a Table 17.82: AC Coil Voltage Codes Table 17.86: 60 Hz Voltage Code 120 208 240/277 480 V02 V08 V39 V28 Table 17.83: Class 8903—Auxiliary Contacts Type Description PBX1 PBX2 X11 X22 Description $ Price 158.00 314.00 Dimensions (Panel Mount) 240 V 277 V 480 V #14 #12 #10 550 900 1425 1650 2700 4275 2200 3600 5700 2925 4700 7550 8800 14400 22800 Max. Volts 100,000 22,000 65,000 600 600 240 Table 17.88: 30–100 A 150–225 A #1/0 Max. 350 MCM Max. #18–#10 #18–#10 2.25 57 7.38 187 2.25 57 9.25 235 8.31 2.88 73 8.50 216 3.00 76 10.50 267 150– 225 C E in. mm in. mm in. mm in. mm in. mm in. mm in. mm b A Dimensions (Bus Mount) Dimensions 150– 14.50 368 7.50 191 3.88 98 225 B Maximum Wire Size (AWG) Control Wire (Cu Only) 30– 100 A Class J Fuses Circuit Breaker—Square D—Type LHL Circuit Breaker—Square D—Type LHL Power Wire (Cu/Al) 30– 11.75 298 7.50 191 3.88 98 100 D Short Circuit Protection Device Recommended Current Range in. W Short-Circuit Ratings RMS Sym. Current (A) Amperes Amperes 208 V Table 17.89: Dimensions H Maximum Distance (feet) 120 V Table 17.87: 243.00 485.00 (1) Auxiliary Contact SPDT (2) Auxiliary Contacts SPDT Table 17.85: Control Distance Wire Gauge AWG Factory Modifications Form H W D A B mm in. mm in. mm in. mm in. mm 211 7.50 191 3.38 86 2.25 57 7.38 187 9.50 241 7.50 191 3.38 86 2.88b 73 8.50 216 Slotted mounting holes suitable for 2.88–3.19 in. mounting centers. A A H $ Price $ Price (1) Auxiliary Contact SPDT (2) Auxiliary Contacts SPDT Table 17.84: Type A B E B H W C W 17-30 D D CP1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Well-Guard™ Pump Panel Reduced Voltage Type Class 8940 / Refer to Catalog 8940CT9701 Coil Voltage Codes Voltage 60 Hz Code 50 Hz $ Price Adder No Charge No Charge No Charge No Charge No Charge No Charge No Charge 35.60 24 V coils are not available on Sizes 4–7. On Sizes 2–3, where 24 V coils are available, Form S (separate control) must be specified. This voltage code must include Form S (no charge). 24c 120d 208 240 — 480 600 Specify c d — 110 — 220 380 440 550 Specify V01 V02 V08 V03 V05 V06 V07 V99 Closed Transition Autotransformer Type, 3-Pole Polyphase—480 Vac Maximum (50–60 Hz) Note: The prices shown do not include thermal units. Overload relays are ambient temperature compensated. Devices require 3 thermal units (Sizes 2–6). Standard trip thermal units are $21.50 each. Motor (Starter) Volts Max. HP Polyphase 15 25 30 50 75 100 25 30 50 75 100 150 200 300 400 600 230 (240) 460 (480) Table 17.92: Coil Voltage Fusible Disconnect Type NEMA Size Fuse Clip Typeb Amperesa 2 60 RD4DV03 100 RE4FV03 3 200 RE1GV03 240@ 60 Hz 220@ 50 Hz 4 200 RF4JV03 400 RG1LV03 5 400 RG1MV03 2 60 RD2FV06 100 RE2GV06 3 100 RE2JV06 200 RF2LV06 4 200 RF2MV06 480 @ 60 Hz 440 @ 50 Hz 400 RG3PV06 5 400 RG3QV06 — — 6 — — 7 — — a Fuse clips are sized for use with dual-element time-delay fuses. Circuit Breaker Type $ Price Circuit Breaker Typeb $ Price 11928.00 FAL36080 VD1DV03 11928.00 17055.00 FAL36100 VE1FV03 17055.00 17342.00 KAL36100 VE2GV03 17342.00 26657.00 KAL36200 VF1JV03 28107.00 43946.00 LAL36250 VG2LV03 43946.00 46083.00 LAL36350 VG2MV03 46083.00 12555.00 FAL36070 VD1FV06 12555.00 17085.00 FAL36080 VE1GV06 17085.00 18197.00 FAL36100 VE1JV06 18197.00 26657.00 KAL36125 VF1LV06 27872.00 28278.00 KAL36200 VF1MV06 28278.00 42735.00 LAL36250 VG4PV06 46340.00 48860.00 LAL36350 VG4QV06 51237.00 — MAL36600 VH1SV06 79338.00 — MAL36900 VH2TV06 79338.00 — MAL361000 VJ1WV06 123134.00 b Coil voltage code must be specified to order this product. Refer to standard voltage codes shown in Table 17.90. Part Winding Type, 3-Pole Polyphase—480 Vac Maximum (50–60 Hz) Note: The prices shown do not include thermal units. Overload relays are ambient temperature compensated. Devices require 6 thermal units (Sizes 2–6). Standard trip thermal units are $21.50 each. Motor (Starter) Voltage Combination Fusible Disconnect Type Max. HP Polyphase 230 (240) 460 (480) 25 30 50 75 100 125 150 30 40 60 75 100 150 200 250 350 Coil Voltage NEMA Size Fuse Clip (2 Sets) Typed (A)c 2PW 60 MD4FV03 60 ME5GV03 3PW 100 ME6JV03 240 @ 60 Hz 4PW 200 MF1LV03 220 @ 50 Hz 200 MG3MV03 5PW 400 MG1NV03 400 MG1PV03 30 MD5GV06 2PW 60 MD2HV06 60 ME7KV06 3PW 100 ME3LV06 480 @ 60 Hz 200 MF3MV06 440 @ 50 Hz 4PW 200 MF3PV06 200 MG4QV06 200 MG4RV06 5PW 400 MG2TV06 c Fuse clips are sized for use with dual-element time-delay fuses. Table 17.93: Part Winding—Reduced Voltage Type Type Figure PD MD PE, PF ME MF PG, MG PH 3 3 3 3 4 4 4 Table 17.94: Type A in. 19.00 23.00 30.00 25.00 36.00 36.00 38.00 B mm 483 584 762 635 914 914 965 in. 34.50 25.50 47.00 52.50 93.00 73.00 93.00 C mm 876 648 1194 1334 2362 1854 2362 in. 12.25 10.60 13.25 12.13 19.25 19.25 19.25 D mm 311 269 337 308 489 489 489 in. 13.00 17.00 22.00 19.00 33.75 33.75 35.75 E mm 330 432 559 483 857 857 908 in. 33.50 24.50 46.00 51.50 12.50 12.50 12.50 F mm 851 622 1168 1308 318 318 318 in. 0.44 0.44 0.56 0.44 0.69 0.69 0.69 mm 11 11 14 11 18 18 18 Autotransformer—Reduced Voltage Type Figure RD, VD 3 RE, VE, RF, VF 4 RG 4 VG 4 VH 4 VJa 4 a Cabinet has double doors. © 2012 Schneider Electric All Rights Reserved Combination Circuit Breaker Type Circuit Breaker $ Price (2 Bkrs.) Typed $ Price Frame Size 7536.00 FAL36070 PD1FV03 7923.00 11609.00 FAL36080 PE3GV03 11322.00 11609.00 FAL36100 PE3JV03 11322.00 21821.00 KAL36150 PF3LV03 23400.00 43326.00 KAL36175 PG2MV03 43326.00 43326.00 LAL36250 PG3NV03 43326.00 43326.00 LAL36250 PG3PV03 43326.00 7536.00 FAL36040 PD1GV06 7293.00 7536.00 FAL36050 PD1HV06 7293.00 11609.00 FAL36070 PE3KV06 12822.00 11609.00 FAL36090 PE3LV06 11322.00 23400.00 FAL36100 PF2MV06 23400.00 23400.00 KAL36125 PF3PV06 23400.00 PG2QV06 43326.00 43326.00 KAL36175 43326.00 KAL36225 PG3RV06 43326.00 43326.00 LAL36300 PG3TV06 43326.00 d Coil voltage code must be specified to order this product. Refer to standard voltage codes shown in Table 17.90. A in. 25.00 32.00 36.00 32.00 34.00 64.00 B mm 635 813 914 813 864 1626 CP1 in. 52.50 72.50 93.00 72.50 93.00 93.00 Discount Schedule C mm 1334 1842 2362 1842 2362 2362 in. 11.13 19.25 19.25 19.25 23.25 27.25 NOTE: D E F mm in. mm in. mm in. mm 283 19.00 483 51.50 1308 0.44 11 489 29.75 756 12.50 318 0.68 17 489 33.75 857 12.50 318 0.69 17 489 29.75 756 12.50 318 0.68 17 591 31.75 806 16.50 419 0.69 17 692 61.75 1568 17.25 438 0.81 21 Illustrations may not represent the actual enclosure; they are intended for dimensional information only. 17-31 NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Type VG4V06K15 Table 17.91: Table 17.90: Class 8940 reduced voltage panels in NEMA 3R enclosures are specifically designed for pumping applications. Extra space is provided for field installation of auxiliary equipment. • Type S contactors/starters provided as standard • All devices are UL Listed, and marked “SUITABLE ONLY FOR USE AS SERVICE EQUIPMENT” • Price includes Hand-Off-Auto selector switch and Start push button For How to Order Information, see Digest 176 page 16-12 and Digest 176 page 16-125 for selection information. 17 www.schneider-electric.us Factory Modifications (Forms) 17 Table 17.95: Reduced Voltage Starters Classs 8606, 8630, 8640 www.schneider-electric.us Reduced Voltage Controllers Only Classes 8606, 8630, 8640 NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS NEMA Size Factory Modifications Enclosure Type Form 1, 4, 12 A 1 1PW 1 YD 2 2 PW 2 YD 3 3 PW 3 YD 336.00 336.00 336.00 4 4 PW 4 YD 5 5 PW 5 YD 6 6 PW 6 YD 7 7 PW 7 YD 336.00 336.00 336.00 Push Buttonsa Start-Stop 33600 Selector Switches Hand-Off-Auto 1, 4, 12 C 336.00 336.00 336.00 336.00 336.00 336.00 336.00 On-Off 1, 4, 12 C6 336.00 336.00 336.00 336.00 336.00 336.00 336.00 1, 4, 12 P 336.00 336.00 336.00 336.00 336.00 336.00 336.00 Pilot Lights (specify color)b One light On Separate Control Circuitde TR coil only (at control voltage) 1, 4, 12 S N/C N/C N/C N/C N/C N/C N/C All coils (at control voltage) 1, 4, 12 Y195 N/C N/C N/C N/C N/C N/C N/C Fused Control Circuitcdef Pilot Devices in Cover and Control Circuit Reduced Voltage Controllers Only Classes 8606 8630 8640 8647 8650 One fuse 1, 4, 12 F 314.00 314.00 314.00 314.00 314.00 N/Ch N/Ch Two fuses 1, 4, 12 F4 314.00 314.00 314.00 314.00 314.00 N/Ch N/Ch Control Circuit Transformercde Standard Capacity (50 or 60 Hz) Fuses Primary Secondary 2— 0— 1, 4, 12 F4T 684.00 882.00 1112.00 1254.00 1395.00 N/Ch N/Ch 2.. 1— 1, 4, 12 FF4T 1026.00 1197.00 1425.00 1566.00 1710.00 314.00 314.00 2— 0— 1, 4, 12 F4T40 912.00 1182.00 1938.00 2079.00 3803.00 3803.00 3803.00 2— 1— 1, 4, 12 FF4T40 1224.00 1497.00 2250.00 2393.00 4116.00 4116.00 4116.00 100 VA additional capacity 1, 4, 12 T11 300.00 300.00 300.00 300.00 300.00 300.00 300.00 200 VA additional capacity 1, 4, 12 T12 570.00 570.00 570.00 570.00 570.00 570.00 570.00 300 VA additional capacity 1, 4, 12 T13 1139.00 1139.00 1139.00 1139.00 1139.00 1139.00 1139.00 400 VA additional capacity 1, 4, 12 T14 2421.00 2421.00 2421.00 2421.00 2421.00 2421.00 2421.00 500 VA additional capacity 1, 4, 12 T15 2721.00 2721.00 2721.00 2721.00 2721.00 2721.00 2721.00 Additional capacity (50 or 60 Hz)g Substitute nonstandard single primary and/or single secondary a b c d e f g h i Voltage rating on the control transformerc 1, 4, 12 T1i 71.00 71.00 71.00 71.00 71.00 — — All push buttons are momentary contact. For pilot light details, refer to the pilot light table in Digest 176 page 16-100. See Table 17.96 below. As standard, Reduced Voltage Controllers are supplied with common control. If Form S or T is specified, only the TR coil will be at control voltage. Specify Form Y195 or T40 (Ex. Form F4T40) if all coils must be at control voltage. Refer to page 17-18 for control circuit arrangements. Reduced Voltage Controllers are supplied with two control circuit fuses for conductors at line voltage. Additional fusing may be supplied if a fused control circuit transformer or separate control is specified. Must be used with Form specifying separate control (Ex. Form FS). Add Form letters and price to that of standard control transformer. (Example: For Size 1, Form F4T, plus 100 VA becomes F4T11, $984.00 Form F4T40 plus 100 VA becomes F4T41, $807.00). Size 6 and 7 controllers come with Form F4T as standard. Must be used in conjunction with a variation of Form of F4T. (Ex. Standard capacity transformer required, 208–24 V. Order as Form F4TT1, 208–24 V.) Table 17.96: Selection of Control Circuit Transformers Voltage 60 Hz (Primary–Secondary) Code 120–12 120–24 208–120 240–24 240–120 277–120 480–24 480–120 480–240 600–120 Specify V88 V89 V84 V82 V80 V85 V83 V81 V87 V86 V99 The standard primary and secondary voltages for control circuit transformers are indicated in Table 17.96. To order, select the desired device with the appropriate transformer Form designation. Then convert the previously selected voltage code (V••) to reflect the desired primary/secondary voltage for the transformer. The secondary voltage should equal the previously selected coil voltage of the device. (24 Vac coils for NEMA Sizes 4–7 are not available). Example: You previously selected a Class 8606SDG1V02S. The designation V02S means that you need a coil voltage of 120-60/110-50 wired for separate control. You would like to add Form FF4T with the transformer voltages being 480 volt primary, 120 volt secondary. The new, complete Class, Type, Voltage Code, and Form are: j 17-32 Class Type Voltage Code Formj 8606 SDG1 V81 FF4T Form numbers should always be shown in alphabetical order. CP1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Factory Modifications (Forms) Reduced Voltage Starters Class 8606, 8630 www.schneider-electric.us Class 8606 Reduced Voltage Starters Only Molded case thermal magnetic circuit breaker b Nonfusible disconnect switch Atuomatic molded case switch NEMA Size Enclosure Type Form 5 6 7 1 4 12 1 4 12 1 4 12 Y791 Y791 Y791 Y792 Y792 Y792 Y7910 Y7910 Y7910 2010.00 2862.00 2037.00 1340.00 2195.00 1368.00 — — — 2451.00 3533.00 2564.00 1710.00 2793.00 1823.00 — — — 2664.00 4886.00 2862.00 2165.00 4388.00 2366.00 — — — 4872.00 7092.00 6579.00 2991.00 5327.00 4815.00 — — — 9471.00 11808.00 10839.00 5355.00 7691.00 5925.00 — — — 13944.00 18216.00 15012.00 — — — 12293.00 16565.00 13361.00 18320.00 23601.00 20397.00 — — — 13004.00 17276.00 14072.00 1 4 12 1 4 12 1 4 12 1 4 12 1 4 12 1 4 12 1 4 12 Y793 Y793 Y793 Y794 Y794 Y794 Y795 Y795 Y795 Y796 Y796 Y796 Y797 Y797 Y797 Y798 Y798 Y798 Y799 Y799 Y799 1566.00 2421.00 1596.00 1566.00 2421.00 1596.00 — — — — — — — — — — — — — — — 1566.00 2124.00 1596.00 1823.00 2885.00 1938.00 — — — — — — — — — — — — — — — — — — 2066.00 3609.00 2280.00 2336.00 4559.00 2537.00 2885.00 5129.00 3105.00 — — — — — — — — — — — — — — — 2574.00 5021.00 2943.00 3596.00 4340.00 5327.00 — — — — — — — — — — — — — — — — — — — — — 5868.00 8190.00 6438.00 — — — — — — — — — — — — — — — — — — 11039.00 15354.00 12861.00 13802.00 18075.00 14871.00 — — — — — — — — — — — — — — — — — — — — — 15425.00 19697.00 17562.00 1 YD 2 YD 3 YD 1 2 3 4 Fusible Disconnect Switch with Fuse Clips a 30 A clips Circuit Breaker or Disconnect Switch 60 A clips 100 A clips 200 A clips 400 A clips Automatic Molded Case Switch with 600 A fuse clips Automatic Molded Case Switch with fuse clips 1200 A or less a b Fuses not included. Mag-Gard™ circuit breakers are not supplied nor recommended. Table 17.98: Class 8630 Reduced Voltage Controllers Onlyd Factory Modifications Molded case thermal magnetic circuit breaker e Nonfusible disconnect switch Atuomatic molded case switch NEMA Size Enclosure Type Form 4 YD 5 YD 6 YD 7 YD 1 4 12 1 4 12 1 4 12 Y791 Y791 Y791 Y792 Y792 Y792 Y7910 Y7910 Y7910 2451.00 3533.00 2564.00 1710.00 2793.00 1823.00 — — — 2664.00 4886.00 2856.00 2165.00 4388.00 2366.00 — — — 4872.00 7092.00 6579.00 2991.00 5327.00 4815.00 — — — 9471.00 11808.00 10839.00 5355.00 7691.00 5925.00 — — — 13944.00 18216.00 15012.00 — — — 12293.00 16565.00 13361.00 18320.00 23601.00 20397.00 — — — 13004.00 17276.00 14072.00 32759.00 37031.00 33827.00 — — — 29483.00 33755.00 30551.00 1 4 12 1 4 12 1 4 12 1 4 12 1 4 12 1 4 12 1 4 12 Y793 Y793 Y793 Y794 Y794 Y794 Y795 Y795 Y795 Y796 Y796 Y796 Y797 Y797 Y797 Y798 Y798 Y798 Y799 Y799 Y799 1823.00 2421.00 1938.00 1823.00 2421.00 1938.00 — — — — — — — — — — — — — — — 1823.00 3771.00 1938.00 2066.00 3609.00 2280.00 2336.00 4559.00 2537.00 — — — — — — — — — — — — — — — — — — 2574.00 5021.00 2943.00 2885.00 5129.00 3105.00 — — — — — — — — — — — — — — — — — — 3596.00 5840.00 5327.00 6510.00 8204.00 6438.00 — — — — — — — — — — — — — — — — — — 11039.00 15354.00 12861.00 13802.00 18075.00 14871.00 — — — — — — — — — — — — — — — — — — 14513.00 18786.00 15227.00 15425.00 19697.00 17562.00 — — — — — — — — — — — — — — — — — — 30195.00 34704.00 31095.00 Fusible Disconnect Switch with Fuse Clipsc 30 A clips Circuit Breaker or Disconnect Switch 60 A clips 100 A clips 200 A clips 400 A clips Automatic Molded Case Switch with 600 A fuse clips Automatic Molded Case Switch with fuse clips 1200 A or less c d e Fuses not included. Wye-Delta motor starters typically have higher current ratings per NEMA Size than full voltage motor starters. Care must be taken in selecting the appropriate short circuit protection. The table on Digest 176 page 7-33 will assist in selecting proper protection based on motor full-load current. Mag-Gard™ circuit breakers are not supplied nor recommended. © 2012 Schneider Electric All Rights Reserved CP1 Discount Schedule 17-33 NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Factory Modifications 17 Table 17.97: Factory Modifications (Forms) Reduced Voltage Starters Class 8640, 8606, 8630 www.schneider-electric.us 17 NOTE: To comply with Section 430-3 of the National Electrical Code®, combination part-winding starters are provided as follows: 1. NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS 2. 3. Table 17.99: Circuit breaker: two thermal-magnetic, adjustable-trip circuit breakers—one for each motor winding. In the smaller controllers that use the FA and KA frames, a single external operating mechanism operates the two circuit breakers simultaneously. In the larger controllers that use the KA and LA frames, each circuit breaker has its own operating mechanism. Nonfusible disconnect switch: a single 3-pole unfused disconnect switch of the proper rating for both windings. The user must provide proper short-circuit protection external to the starter, using only Class J fuses. Fusible disconnect switch: a single unfused disconnect switch with two sets of fuse clips (each set of the rating indicated) to provide short-circuit protection for each winding. Class 8640 Reduced Voltage Starters Only Factory Modifications Molded case thermal magnetic circuit breaker b NEMA Size Enclosure Type Form 1 Y7911 3014.00 3675.00 3996.00 7307.00 14207.00 — 4 Y7911 4293.00 5300.00 7329.00 10641.00 17711.00 — 12 Y7911 3056.00 3846.00 4293.00 9872.00 16259.00 — 1 Y7931 2006.00 2006.00 — — — — 4 Y7931 2664.00 2664.00 — — — — 12 Y7931 2132.00 2132.00 — — — — 1 Y7941 — 2273.00 2570.00 — — — 4 Y7941 — 3969.00 5013.00 — — — 12 Y7941 — 2507.00 2790.00 — — — 1 Y7951 — 2570.00 2831.00 3176.00 — — 4 Y7951 — 5013.00 5525.00 5642.00 — — 12 Y7951 — 2790.00 3239.00 3416.00 — — 1 Y7961 — — 3176.00 3959.00 6456.00 — 4 Y7961 — — 5642.00 6425.00 9026.00 — 12 Y7961 — — 3416.00 5859.00 7082.00 1 Y7971 — — — 6456.00 1 PW 2 PW 3 PW 4 PW 5 PW 6 PW Fusible Disconnect Switch with Fuse Clips a 30 A clips (two sets) 60 A clips (two sets) Circuit Breaker or Disconnect Switch 100 A clips (two sets) 200 A clips (two sets) 400 A clips (two sets) Automatic molded case switch with 600 A fuse clips (two sets) Automatic molded case switch with fuse clips 601–1200 A or less (two sets) a b c — 15182.00 c 15596.00 c 4 Y7971 — — — 9026.00 19881.00 c 20082.00 c 12 Y7971 — — — 7082.00 16356.00 c 16592.00 c 1 Y7920 — — — — — 15965.00 4 Y7920 — — — — — 20664.00 12 Y7920 — — — — — 16748.00 1 Y7921 — — — — — 16968.00 4 Y7921 — — — — — 21668.00 12 Y7921 — — — — — 19319.00 Fuses not included. Mag-Gard™ circuit breakers are not supplied nor recommended. Consists of automatic molded case switch with two sets of 400 A fuse clips. Table 17.100: Reduced Voltage Controllers Onlyc Classes 8606, 8630, 8640 NEMA Size Factory Modifications Non-Compensated Bimetallic Overload Relays Three Element Types SC-SD (Sizes 1 & 2) Types SE-SG (Sizes 3–5) Type SH (Size 6) Overload Relays Ambient Compensated Bimetallic Overload Relays Three Element Types SC-SD (Sizes 1 & 2) Types SE-SF (Sizes 3 & 4) Types SG-SH (Sizes 5–6) Overload Relays General Substitute 9999SO4 isolated alarm contact on melting alloy overload relay Substitute 9999SO5 isolated alarm contact on melting alloy overload relay Motor Logic™ Overload Relaysde Miscellaneous a b c d e 17-34 Add for thermal protector Class 8606 Coil transient suppressor per coil Addition of terminal blocks (specify wired or unwired). Wired, per terminal, each Unwired, per terminal, each Enclosure Type Form Any Any Any B2 B5 B2 57.00 — — 57.00 — — — 57.00 — — 57.00 — — 57.00 — — — 57.00 — — — b 1, 4, 12 Any Any B Y59 B 86.00 — — 86.00 — — — 107.00 — — 107.00 — — — 86.00 — — 86.00 — — — b Any Any Y342 Y344 179.00 179.00 179.00 179.00 179.00 179.00 179.00 179.00 179.00 179.00 179.00 179.00 — b — b Any Any H10 H20 122.00 122.00 122.00 122.00 122.00 122.00 122.00 122.00 122.00 122.00 57.00 57.00 57.00 57.00 1, 4, 12 Any Y116 Y145 — 158.00 570.00 158.00 570.00 158.00 570.00 158.00 570.00 158.00 570.00 — — — 1, 4, 12 1, 4, 12 G56a G50a 116.00 57.00 116.00 57.00 116.00 57.00 116.00 57.00 116.00 57.00 116.00 57.00 116.00 57.00 1 1PW 1 YD 2 2 PW 2 YD 3 3 PW 3 YD 4 4 PW 4 YD 5 5 PW 5 YD 6 6 PW 6 YD 7 7 PW 7 YD Addition of terminal block 9080CA or 9080GR6 only. The number of circuits is the same as the ending of the Form number. (Example: G505 is 5 wire terminal block.) Available in groups of 5 only. Order in increments of 5. The number of circuits is the same as the ending of the Form number. (Example: G505 = 5 unwired terminals, G510 is 10 unwired terminals.) Size 7 uses a solid-state overload relay. See Class 8536 for complete details. NEMA Type 7 and 9 enclosures not available with Class 8600 devices. Motor Logic overload relays are not available on Class 8640 Size 1PW to 4PW starters. See Motor Logic overload relays in the Full Voltage section on the bottom of Digest 176 page 16-83 for additional Form options of Motor Logic overload relays. CP1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Definite Purpose Contactors Reversing/Hoist, Type R Class 8965 reversing hoist contactors meet the small space requirements found in electrical hoists, light duty cranes, door operators, and related products. They are designed to perform in the short periods of jogging experienced in hoist service. Note that these contactors must be mounted upright on the vertical plane; the contactors will not operate properly when mounted in any other position. Table 17.101: AC Reversing/Hoist Contactors—600 Vac Maximum Horsepower Ratings No. of Poles Type RO10V02 115 V 1Ø 230 V 1Ø 230 V 3Ø Power Terminals 460/575 V 3Ø Witha Jumper Straps Withouta Jumper Straps Open Type Open Type $ Price Quick Connect RO10c RO11c 3-Pole 1 1-1/2 3 3 Polyphase Pressure Wireb RO12c RO13c a Jumper straps connect the line side power terminals of the same phase between the forward (up) and reverse (down) contactors in common; i.e., L1 to L1, L2 to L2, and L3 to L3. b Coils rated 120 Vac or less are supplied with quick connect terminals only. c Voltage code must be specified to order this product. Refer to standard voltage codes shown in Table 17.105. 998.00 Table 17.102: Miscellaneous Hoist Contactor Kits For Use With Class 8965 Type Series Description RO10 Armature Kit RO11 A&B Contact RO12 Carrier RO13 d CP10 discount schedule. e One armature per kit. Class 9998 Type RP1e Series Description Armature Kit C Contact Carrier Order as Part Number 3100206050 Class 9998 Type RP2e $ Priced 29.40 Order as Part Number 3100208150 39.40 Table 17.103: Class 8965 Replacement Contact Kits Device Type Device Series Class 9998 Kit Type Device Series Class 9998 Kit Type RO10 RA10 RA14 RO11 RA11 RA15 A&B RO12 C RA12 RO13 RA16 RA13 RA17 Terminals 1 N.O. Each Side Quick Connect Screw Quick Connect Screw 1 N.C. Each Side Class 9999 Type R10 R12 R11 R13 236.00 B F $ Price E Replacement Part Number 3100240319g 3100240340g 3100240047h 3100240049h 3100240058hi 3100240060h D 50.00 A Table 17.106: Approximate Dimensions (3 Poles per Contactor) Table 17.105: Coil Table Voltage Voltage Voltage 60 Hz 50 Hz Code 24 — V01 120 110 V02 208/220 — V21 240 220 V03 480 440 V06 600 550 V07 f CP10 Discount Schedule. g Tape wound coils, 2 per package. h Molded coil, 1 per package. i Suitable for 440 V 50 Hz applications. G 202.00 Table 17.104: Auxiliary Contacts Separate Module Description C Provisions for (3) #8 Mounting Screws $ Price $ Pricef 119.00 119.00 114.00 114.00 114.00 83.00 Type A B C D E F G RO10, 11 3.31 84 3.31 84 3.03 77 2.69 68 1.34 34 1.56 40 2.66 68 RO12, 13 3.31 84 3.69 94 2.69 68 2.69 68 1.34 34 1.56 40 2.66 68 Table 17.107: Cross Reference—Obsolete Devices Obsolete Device Class 8702 or 8965 8965 Type HO3 HO4 HO5 HO6 HO7 HO8 RG2S1 RG5S1 RG5S2 RO1 RO1S1 RO1S2 RO1S3 RO1S4 RO1S5 RO1S6 Replacement Device Class Auxiliary Contact Required Type RO12 RO12 RO12 RO12 RO12 RO12 RO10 RO12 RO12 RO10 RO11 RO10 RO11 RO10 RO10 RO10 8965 8965 Class — 9999 9999 — 9999 9999 9999 9999 9999 — — — — — — — Burden Type — R12 R13 — R12 R13 R10 R12 R12 — — — — — — — Class Type 8965 RO2 RO2S1 RO2S2 RO3 RO3S1 RO3S2 RO3S3 RO4 RO4S1 RO5 RO5S1 RO5S2 RO6 RO6S1 RO6S2 Replacement Device Auxiliary Contact Required Class Type Class Type 8965 RO10 RO11 RO10 RO10 RO11 RO10 RO10 RO12 RO13 RO12 RO13 RO12 RO12 RO13 RO12 9999 9999 9999 9999 9999 9999 9999 — — 9999 9999 9999 9999 9999 9999 R10 R10 R10 R11 R11 R11 R11 — — R12 R12 R12 R13 R13 R13 Table 17.108: How to Order Application Data Coils Obsolete Device Duty: Hoist Duty—H4 Intermittent Voltage Range: AC coils only; +10%, –15% of nominal Inrush 76 VA, Sealed 27 VA To Order Specify: • • • Class Number Type Number Voltage and Frequency Catalog Number Class Type Voltage and Frequency 8695 RO10 V02 Approvals UL Component Recognized: File E78351, CCN NLDX2 CSA Certified: File LR60905, Class 3211 04 © 2012 Schneider Electric All Rights Reserved CP1 CP10 Discount Schedule 17-35 17 www.schneider-electric.us NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Class 8965 / Refer to Catalog 8910CT9301 Thermal Overload Relays—NEMA Style Solid-State Overload Relay, Motor Logic™ Plus Class 9065 / Refer to Catalog 9065CT9701 17 Motor Logic Plus—Class 9065 NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS The Motor Logic Plus solid-state overload relay is separately powered and fully programmable. It is designed to protect 3-phase AC motor applications, 200–480 Vac or 600 Vac. The SSOLR has one Form C relay output rated for 300 Vac maximum. Motor Logic Plus Lug-Lug Kit This kit can be field installed on separately mounted Motor Logic Plus overload relays. Table 17.111: Lug-Lug Kit For Use With Table 17.109: Motor Logic Plus Class 9065 SP Solid-State Overload Relay $ Price 200 to 480 V 600 V Current Range SPB4 SPB6 0.5–2.3 A SPC4 SPC6 2.0–9.0 A SP14 SP16 6.0–27.0 A SP24 SP26 10.0–45.0 A 957.00 SP34 SP36 20.0–90.0 A SP44j SP46j 60.0–135.0 A SP54k SP56k 120.0–270.0 A SP64l SP66l 240.0–540.0 A j Must use 150:5 external current transformer, purchased separately. k Must use 300:5 external current transformer, purchased separately. l Must use 600:5 external current transformer, purchased separately. Class & Type NEMA Size 8536 SA-SH 1–6 9065 SP 1–6 Parts Kit Description Class 9999 Type $ Price Lug-Lug Kit MLPL 80.00 Software Kit Solutions software program allows an IBM PC compatible computer (with Windows 95 or greater) to communicate with a Motor Logic Plus overload relay connected to an RS-485 network using Modbus protocol. Table 17.112: Software Kit Table 17.110: Forms for factory addition to 8536 Open Style only For Use With Alpha Character B Motor Logic Plus Overload Relay Class & Type First Digit 2 3 4 5 6 7 8 9 Current Ranges 0.5–2.3 A 2.0–9.0 A 6.0–27.0 A 10.0–45.0 A 20.0–90.0 A 60.0–135.0 A 120.0–270.0 A 240.0–540.0 A 8536 SA–SH Second Digit 0 2 4 6 www.schneider-electric.us NEMA Size Parts Kit Description Class 9999 Type 1–6 Software Kit MLPS 9065 SP $ Price 1295.00 Communication Module This module allows the Motor Logic Plus overload relay to support RS-485 electrical communications standards. Up to 99 Motor Logic Plus overload relays can be controlled and monitored from one remote personal computer. Modifications No modification for 200–480 V Add communication module for 200–480 V No modification for 600 V Add communication module for 600 V Table 17.113: Communication Module For Use With Example Class & Type Form B 4 2 Motor Logic Plus overload relay with a current range of 6–27 A and modifications to add communication module for an open style starter package. Parts Kit Description Class 9999 Type Modbus Communication Module MB22 NEMA Size 8536 SA-SH 1–6 9065 SP $ Price 171.00 Table 17.114: How to Order To Order Specify: • • Catalog Number Class Number Type Number Class Type 9999 AC04 Table 17.115: Full Voltage Controllers Only Classes 8502, 8536, 8538, 8539, 8702, 8736, 8738, 8739, 8810, 8811 and 8812 Factory Modifications Non-Compensated Bimetallic Overload Relays Single Phase: Types SB–SD (Sizes 0–2)b Overload Relays a b c 17-36 Polyphase: Two Element—For 2 Phase Only Types SB–SD (Sizes 0–2) Three Element Types SB–SD (Sizes 0–2) Type SG (Size 5) Type SH (Size 6) Ambient Compensated Bimetallic Overload Relays Three Element Types SB–SD (Sizes 0–2) Types SE–SF (Sizes 3 & 4) Type SG (Size 5) Type SH (Size 6) NEMA Size Enclosure Type Form Any B1 — 35.60 35.60 Any B1 — 35.60 Any Any Any B2 B2 B2 — — — 1, 4, 7, 9, 12 Any Any Any B Y59 B B — — — — 00 Overload Relays—General Any Y81 — Modify Size 3 Type SE starters with melting alloy overload relays to accept Type FB quick trip or SB slow trip thermal units Substitute 9999 SO4 isolated alarm contact (N.O.) Any Y342 179.00 on melting alloy overload relay Substitute 9999 SO5 isolated alarm contact (N.C.) Any Y344 179.00 on melting alloy overload relay Size 7 uses a solid state overload relay as standard. See Class 8536 for complete details. Single phase bimetallic overload relays for Type S Sizes 0–2 require two (2) thermal units per starter. For Classes 8736, 8738 and 8739 Type SG, consult Schneider Electric CCC at (1-888-778-2733). CP1 Discount Schedule 0 1 2 3 4 5 6 7 35.60 — — — — — 35.60 35.60 — — — — — 35.60 — — 35.60 — — 35.60 — — — — — — — — — 35.60 — — — 35.60 — — — a 64.00 — — — 64.00 — — — 64.00 — — — — 64.00 — — — — 64.00 — — — — 64.00 — — — — a — — — 179.00 179.00 179.00 179.00 179.00 179.00 — 64.00 — — N/C 179.00 179.00 — — — — 179.00 179.00 c 179.00 — a 179.00 179.00 c 179.00 — a © 2012 Schneider Electric All Rights Reserved
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : mra632 Create Date : 2014:04:02 13:06:17Z Modify Date : 2014:04:04 18:41:26-04:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Creator Tool : FrameMaker 9.0 Metadata Date : 2014:04:04 18:41:26-04:00 Producer : Acrobat Distiller 9.2.0 (Windows) Format : application/pdf Title : nema-contactors-and-staters-sd.book Creator : mra632 Document ID : uuid:e30353b8-b5e3-4630-a97f-ffc898a40968 Instance ID : uuid:ef508ee8-bea6-4214-bb27-11e73dc0319d Page Mode : UseNone Page Count : 36EXIF Metadata provided by EXIF.tools