STC (Dongguan) Company Limited EC DECLARATION OF CONFORMITY LVD-D161916DOC Reference Number: Intracom Asia Co., Ltd 4F., No.77, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221, Taiwan declare the product Description: Brand Name: Model: 8-Port PoE+ Desktop Gigabit Switch Intellinet 560641 complies with the requirements of the th EC Low Voltage Directive 2006/95/EC (until April 19 , 2016) and th EC Low Voltage Directive 2014/35/EU (from April 20 , 2016) Applicable Standard(s) with amendments: EN 60950-1:2006+A11:2009+A1:2010+A12: 2011+A2:2013 General Remarks: This declaration is only valid when used in conjunction with the technical file(s) refers to DE115902 This declaration applies specifically to the sample(s) investigated in the technical report mentioned above and not to the bulk. The CE mark as shown below can be used, under the responsibility of the manufacturer, after completion of an EC Declaration of Conformity and compliance with all relevant EC Directives. Manufacturer/Importer Test Laboratory LI Chang Jun, Ricky Authorized Signatory Electrical Safety Department For and on behalf of STC (Dongguan) Company Limited Signature www.dgstc.org Date of Issue: 2016-04-13 TEST REPORT IEC/EN 60950-1 Information technology equipment – Safety – Part 1: General requirements Report Number. .............................. : DE115902 Date of issue................................... : 2016-04-13 Total number of pages ................... Page 1 to 59 for test report Appendix 1 to 5 for product photographs Testing Laboratory ........................ : STC (Dongguan) Company Limited Address ........................................... : 68 Fumin Nan Road, Dalang , Dongguan City, Guangdong Province, P.R. China Applicant’s name ........................... : Intracom Asia Co., Ltd Address ........................................... : 4F., No.77, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221, Taiwan Test specification: Standard ......................................... : IEC 60950-1:2005 (2nd Edition); Am 1:2009; Am 2: 2013 EN 60950-1:2006+A11:2009+A1:2010+A12: 2011+A2:2013 Test procedure ............................... : N/A Non-standard test method………..: N/A Test Report Form No. .................... : IEC60950_1B_M2 Test Report Form(s) Originator .... : SGS Fimko Ltd Master TRF ..................................... : Dated 2010-04 Modified by ..................................... : STC Modified Date ................................. : 2013-12 Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : 8-Port PoE+ Desktop Gigabit Switch Trade Mark ...................................... : Intellinet Manufacturer .................................. : Intracom Asia Co., Ltd Address ........................................... : 4F., No.77, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221, Taiwan Model/Type reference .................... : 560641 Ratings ............................................ : 100-240VAC 50/60Hz, Max.2.2A TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 2 of 59 Report No.: DE115902 Testing procedure and testing location: Testing Laboratory: Testing location/ address ...................... : STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong Province, P.R. China Associated Laboratory: Testing location/ address ...................... : Tested by (name + signature) ..... : Amy Lin Approved by (+ signature) ........... : Ricky Lee Testing procedure: TMP Tested by (name + signature) ..... : Approved by (+ signature) ............ : Testing location/ address ...................... : Testing procedure: WMT Tested by (name + signature) ..... : Witnessed by (+ signature) .......... : Approved by (+ signature) ........... : Testing location/ address ...................... : Testing procedure: SMT Tested by (name + signature) ..... : Approved by (+ signature) ............ : Supervised by (+ signature) ........ : Testing location/ address ................ : Testing procedure: RMT Tested by (name + signature) ..... : Approved by (+ signature) ............ : Supervised by (+ signature) ........ : Testing location/ address ...................... : TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 3 of 59 Report No.: DE115902 List of Attachments (including a total number of pages in each attachment): Page 1 to 59 for test report Appendix 1 to 5 for product photographs Summary of testing: The sample(s) tested complies with the requirements of EN 60950-1:2006+ A11:2009+ A1:2010+ A12:2011 +A2:2013 Tests performed (name of test and test clause): EN 60950-1:2006+ A11:2009+ A1:2010+A12:2011 + A2:2013 Testing location: 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong Province, P.R. China Summary of compliance with National Differences List of countries addressed: Europe The product fulfils the requirements of EN 60950-1:2006+ A11:2009+ A1:2010+A12:2011+A2:2013 Copy of marking plate: TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 4 of 59 Report No.: DE115902 Test item particulars .................................................. : 8-Port PoE+ Desktop Gigabit Switch Equipment mobility ................................................ : [x] movable [] stationary [] hand-held [] transportable [] for building-in [] direct plug-in Connection to the mains ........................................ : [x] pluggable equipment [x] type A [] type B [] permanent connection [x] detachable power supply cord [] non-detachable power supply cord [] not directly connected to the mains Operating condition ................................................ : [x] continuous [] rated operating / resting time: Access location ...................................................... : [x] operator accessible [] restricted access location Over voltage category (OVC) ................................ : [] OVC I [x] OVC II [] OVC III [] other Mains supply tolerance (%) or absolute mains +6%, -10% supply values .......................................................... : Tested for IT power systems ................................. : [] Yes [] OVC IV [x] No IT testing, phase-phase voltage (V) ...................... : N/A Class of equipment ................................................ : [x] Class I [] Class II [] Class III [] Not classified Considered current rating of protective device as 16A part of the building installlation (A) ...................... : Pollution degree (PD) ............................................. : [] PD 1 [x] PD 2 [] PD 3 IP protection class .................................................. : IPX0 Altitude during operation (m) ................................ : 2000 Altitude of test laboratory (m) ............................... : < 2000 Mass of equipment (kg) ......................................... : 1.8kg Possible test case verdicts: - test case does not apply to the test object ............ : N (N/A) - test object does meet the requirement .................. : P (Pass) - test object does not meet the requirement............ : F (Fail) Testing .......................................................................... : Date of receipt of test item ......................................... : 2014-08-20; 2014-12-08 Date(s) of performance of tests ................................. : 2014-08-20 to 2014-10-16; 2014-12-08 to 2014-12-23 TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 5 of 59 Report No.: DE115902 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. This report shall not be reproduced unless prior written approval from STC (Dongguan) Company Limited For Conditions of issuance of this test report, please refer to the below Homepage. Page 1 to 59 for test report Appendix 1 to 5 for product photographs Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: When differences exist; they shall be identified in the General product information section. General product information: The submitted unit is Class I 8-Port PoE+ Desktop Gigabit Switch, Which including POE function and net function. Power output up to 34watts on ports 1-4 (IEEE 802.3at); and power output up to 15.4watts on ports 5-8 (IEEE 802.3af). It supplied by mains via a detachable power supply cord. The max operated temperature is 40C which is specified by manufacturer. Abbreviations used in the report: - normal conditions - functional insulation - double insulation - between parts of opposite polarity N.C. OP DI BOP - single fault conditions - basic insulation - supplementary insulation - reinforced insulation Indicate used abbreviations (if any) TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org S.F.C BI SI RI Page 6 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 1 GENERAL P 1.5 Components P 1.5.1 General P Comply with IEC 60950-1 or relevant component standard Result - Remark see appended table Verdict P 1.5.2 Evaluation and testing of components P 1.5.3 Thermal controls Not used N 1.5.4 Transformers See Annex C P 1.5.5 Interconnecting cables No hazards P 1.5.6 Capacitors bridging insulation Approved capacitor used P 1.5.7 Resistors bridging insulation No such resistors N 1.5.7.1 Resistors bridging functional, basic or supplementary insulation N 1.5.7.2 Resistors bridging double or reinforced insulation between a.c. mains and other circuits N 1.5.7.3 Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable N 1.5.8 Components in equipment for IT power systems Not for IT power distribution systems N 1.5.9 Surge suppressors Varistor V1 was approved P 1.5.9.1 General See Annex Q P 1.5.9.2 Protection of VDRs Fuse F1 used P 1.5.9.3 Bridging of functional insulation by a VDR P 1.5.9.4 Bridging of basic insulation by a VDR N 1.5.9.5 Bridging of supplementary, double or reinforced insulation by a VDR 1.6 Power interface 1.6.1 AC power distribution systems TN P 1.6.2 Input current (see appended table 1.6.2) P 1.6.3 Voltage limit of hand-held equipment Not hand-held equipment N 1.6.4 Neutral conductor N 1.7 Marking and instructions P 1.7.1 Power rating and identification markings 1.7.1.1 Power rating marking P Multiple mains supply connections..........................: N No such Varistor N P See below P Rated voltage(s) or voltage range(s) (V) ...............: 100-240V P Symbol for nature of supply, for d.c. only ...............: AC input N TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 7 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause 1.7.1.2 Requirement + Test Result - Remark Verdict Rated frequency or rated frequency range (Hz) ....: 50/60Hz P Rated current (mA or A) ........................................: Max. 2.2A P Identification markings See copy of marking plate P Manufacturer‟s name or trade-mark or identification mark .......................................................................: Intellinet P Model identification or type reference .....................: 560641 P Symbol for Class II equipment only ........................: Class I N Other markings and symbols .................................: Additional symbol or marking does not give rise to misunderstanding. P 1.7.1.3 Use of graphical symbols P 1.7.2 Safety instructions and marking P 1.7.2.1 General P 1.7.2.2 Disconnect devices 1.7.2.3 Overcurrent protective device N 1.7.2.4 IT power distribution systems N 1.7.2.5 Operator access with a tool N 1.7.2.6 Ozone No ozone radiation N 1.7.3 Short duty cycles Continuous operation N 1.7.4 Supply voltage adjustment ....................................: N Methods and means of adjustment; reference to installation instructions ..........................................: N Appliance coupler as disconnect divices P 1.7.5 Power outlets on the equipment ...........................: No such power outlets N 1.7.6 Fuse identification (marking, special fusing characteristics, cross-reference) ..........................: F1: T5A 250VAC P 1.7.7 Wiring terminals 1.7.7.1 Protective earthing and bonding terminals ...........: 1.7.7.2 P P Terminals for a.c. mains supply conductors on inlet No such terminal provided N 1.7.7.3 Terminals for d.c. mains supply conductors No d.c. mains N 1.7.8 Controls and indicators P 1.7.8.1 Identification, location and marking ......................: N 1.7.8.2 Colours ................................................................: 1.7.8.3 Symbols according to IEC 60417 ......................... : P 1.7.8.4 Markings using figures ........................................ : P 1.7.9 Isolation of multiple power sources ..................... : N 1.7.10 Thermostats and other regulating devices .......... : No such adjustable devices N 1.7.11 Durability Legible after test P 1.7.12 Removable parts No such parts N TRF No. IEC60950_1B_M2 No colour impairs safety STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N Page 8 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 1.7.13 Replaceable batteries .......................................... : No such battery N Language(s) ......................................................... : 1.7.14 Equipment for restricted access locations ............ : Not for installation in restricted access locations N 2 PROTECTION FROM HAZARDS P 2.1 Protection from electric shock and energy hazards P 2.1.1 Protection in operator access areas P 2.1.1.1 Access to energized parts Cannot touch live part and basic insulation P Test by inspection ..................................................: No hazards P Test with test finger (Figure 2A) ............................: No hazards P Test with test pin (Figure 2B) .................................: No hazards P Test with test probe (Figure 2C) ............................: No hazards P 2.1.1.2 Battery compartments No compartments N 2.1.1.3 Access to ELV wiring No ELV circuit N Working voltage (Vpeak or Vrms); minimum distance through insulation (mm) 2.1.1.4 Access to hazardous voltage circuit wiring N 2.1.1.5 Energy hazards ......................................................: (see appended tables 2.1.1.5) P 2.1.1.6 Manual controls No manual control N 2.1.1.7 Discharge of capacitors in equipment CX1: 0.47μF; CX2: 0.47μF P Measured voltage (V); time-constant (s) ................: 7V after 1s 2.1.1.8 Energy hazards – d.c. mains supply N a) Capacitor connected to the d.c. mains supply ...: N b) Internal battery connected to the d.c. mains supply .....................................................................: N 2.1.1.9 Audio amplifiers .....................................................: 2.1.2 Protection in service access areas N 2.1.3 Protection in restricted access locations N 2.2 SELV circuits P 2.2.1 General requirements P 2.2.2 Voltages under normal conditions (V) ...................: (see appended tables 2.2) P 2.2.3 Voltages under fault conditions (V) ........................: (see appended tables 2.2) P 2.2.4 Connection of SELV circuits to other circuits ....... : Connect to SELV circuit only P 2.3 TNV circuits TRF No. IEC60950_1B_M2 No such componet STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N P Page 9 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 2.3.1 Limits Type of TNV circuits ...............................................: Result - Remark Verdict P TNV-1 2.3.2 Separation from other circuits and from accessible parts P 2.3.2.1 General requirements P 2.3.2.2 Protection by basic insulation P 2.3.2.3 Protection by earthing P 2.3.2.4 Protection by other constructions ..........................: N 2.3.3 Separation from hazardous voltages P Insulation employed ................................................: 2.3.4 Main protective earthing terminal used Connection of TNV circuits to other circuits N Insulation employed ................................................: 2.3.5 Test for operating voltages generated externally N 2.4 Limited current circuits P 2.4.1 General requirements Considered. P 2.4.2 Limit values 173.6mA P Frequency (Hz) .......................................................: 248KHz Measured current (mA) ...........................................: 3.47mA Measured voltage (V) .............................................: 6.94V Measured circuit capacitance (nF or µF) ................: CY3: 3300PF 2.4.3 Connection of limited current circuits to other circuits Under normal operating condition and in the event of a single failure P 2.5 Limited power sources N a) Inherently limited output N b) Impedance limited output N c) Regulating network limited output under normal operating and single fault condition (see appended table 2.5) N d) Overcurrent protective device limited output N Max. output voltage (V), max. output current (A), max. apparent power (VA) ......................................: Current rating of overcurrent protective device (A) .: Use of integrated circuit (IC) current limiters 2.6 Provisions for earthing and bonding P 2.6.1 Protective earthing P TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 10 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark 2.6.2 Functional earthing N 2.6.3 Protective earthing and protective bonding conductors P 2.6.3.1 General P 2.6.3.2 Size of protective earthing conductors 2 Rated current (A), cross-sectional area (mm ), AWG .......................................................................: 2.6.3.3 Verdict Power cord set P 2 2.2A, 0.75mm Size of protective bonding conductors P 2 Rated current (A), cross-sectional area (mm ), AWG .......................................................................: Protective current rating (A), cross-sectional area 2 (mm ), AWG ...........................................................: 2.2A, 18AWG 2.6.3.4 Resistance of earthing conductors and their terminations; resistance (), voltage drop (V), test current (A), duration (min) ......................................: 0.022Ω P 2.6.3.5 Colour of insulation .................................................: The color combination green and yellow is used P 2.6.4 Terminals P 2.6.4.1 General P 2.6.4.2 Protective earthing and bonding terminals Appliance coupler used P Rated current (A), type, nominal thread diameter (mm) .......................................................................: 2.6.4.3 Separation of the protective earthing conductor from protective bonding conductors P 2.6.5 Integrity of protective earthing P 2.6.5.1 Interconnection of equipment N 2.6.5.2 Components in protective earthing conductors and protective bonding conductors P 2.6.5.3 Disconnection of protective earth N 2.6.5.4 Parts that can be removed by an operator 2.6.5.5 Parts removed during servicing N 2.6.5.6 Corrosion resistance N 2.6.5.7 Screws for protective bonding P 2.6.5.8 Reliance on telecommunication network or cable distribution system N 2.7 Overcurrent and earth fault protection in primary circuits P 2.7.1 Basic requirements P 2.7.2 Applianc coupler Fuse F1 used P Instructions when protection relies on building installation N Faults not simulated in 5.3.7 N TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 11 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark 2.7.3 Short-circuit backup protection By building installation P 2.7.4 Number and location of protective devices ........... : One fuse P 2.7.5 Protection by several devices N 2.7.6 Warning to service personnel ................................ : N 2.8 Safety interlocks N 2.8.1 General principles 2.8.2 Protection requirements N 2.8.3 Inadvertent reactivation N 2.8.4 Fail-safe operation N Protection against extreme hazard N 2.8.5 Moving parts N 2.8.6 Overriding N 2.8.7 Switches, relays and their related circuits N 2.8.7.1 Separation distances for contact gaps and their related circuits (mm) .............................................. : N 2.8.7.2 Overload test N 2.8.7.3 Endurance test N 2.8.7.4 Electric strength test 2.8.8 Mechanical actuators N 2.9 Electrical insulation P 2.9.1 Properties of insulating materials P 2.9.2 Humidity conditioning 48 hrs P Relative humidity (%), temperature (°C) ............... : 30°C, 93% 2.9.3 Grade of insulation Basic insulation P 2.9.4 Separation from hazardous voltages Method(s) used ..................................................... : No safety interlocks (see appended table 5.2) Verdict N N P Method 1 2.10 Clearances, creepage distances and distances through insulation P 2.10.1 General P 2.10.1.1 Frequency .............................................................. : <30KHz P 2.10.1.2 Pollution degrees ................................................... : 2 P 2.10.1.3 Reduced values for functional insualtion P 2.10.1.4 Intervening unconnected conductive parts P 2.10.1.5 Insulation with varying dimensions N 2.10.1.6 Special separation requirements N TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 12 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark 2.10.1.7 Insulation in circuits generating starting pulses N 2.10.2 Determination of working voltage P 2.10.2.1 General 2.10.2.2 RMS working voltage P 2.10.2.3 Peak working voltage P 2.10.3 Clearances N 2.10.3.1 General P 2.10.3.2 Mains transient voltages 2500V P a) AC mains supply ................................................ : 100-240V P See appended table 2.10.2 Verdict P b) Earthed d.c. mains supplies .............................. : N c) Unearthed d.c. mains supplies .......................... : N d) Battery operation ............................................... : N 2.10.3.3 Clearances in primary circuits See appended table 2.10.3 & 2.10.4 2.10.3.4 Clearances in secondary circuits N 2.10.3.5 Clearances in circuits having starting pulses N 2.10.3.6 Transients from a.c. mains supply ......................... : N 2.10.3.7 Transients from d.c. mains supply ......................... : N 2.10.3.8 Transients from telecommunication networks and cable distribution systems ...................................... : N 2.10.3.9 Measurement of transient voltage levels N a) Transients from a mains suplply N For an a.c. mains supply ........................................ : N For a d.c. mains supply .......................................... : N b) Transients from a telecommunication network : N 2.10.4 Creepage distances 2.10.4.1 General P 2.10.4.2 Material group and caomparative tracking index P CTI tests ................................................................. : See appended table 2.10.3 & 2.10.4 P IIIb P 2.10.4.3 Minimum creepage distances 2.10.5 Solid insulation 2.10.5.1 General P 2.10.5.2 Distances through insulation P 2.10.5.3 Insulating compound as solid insulation N 2.10.5.4 Semiconductor devices N 2.10.5.5. Cemented joints N 2.10.5.6 Thin sheet material – General N TRF No. IEC60950_1B_M2 P See appended table 2.10.5 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org P Page 13 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 2.10.5.7 Separable thin sheet material N Number of layers (pcs) ........................................... : 2.10.5.8 Non-separable thin sheet material N 2.10.5.9 Thin sheet material – standard test procedure N Electric strength test Thin sheet material – alternative test procedure N Electric strength test 2.10.5.11 Insulation in wound components P 2.10.5.12 Wire in wound components P Working voltage ..................................................... : N a) Basic insulation not under stress ....................... : N b) Basic, supplemetary, reinforced insulation ........ : N c) Compliance with Annex U .................................. : N 2.10.5.10 Two wires in contact inside wound component; angle between 45 and 90 .................................... : 2.10.5.13 Result - Remark Separated by tape and tube Verdict P Wire with solvent-based enamel in wound components N Electric strength test Routine test N Additional insulation in wound components N Working voltage ..................................................... : N - Basic insulation not under stress ......................... : N - Supplemetary, reinforced insulation .................... : N 2.10.6 Construction of printed boards P 2.10.6.1 Uncoated printed boards 2.10.6.2 Coated printed boards N 2.10.6.3 Insulation between conductors on the same inner surface of a printed board N 2.10.6.4 Insulation between conductors on different layers of a printed board N Distance through insulation N Number of insulation layers (pcs) ........................... : N 2.10.7 Component external terminations N 2.10.8 Tests on coated printed boards and coated components N 2.10.8.1 Sample preparation and preliminary inspection N 2.10.8.2 Thermal conditioning N 2.10.8.3 Electric strength test N 2.10.5.14 TRF No. IEC60950_1B_M2 See appended table 2.10.3 & 2.10.4 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org P Page 14 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 2.10.8.4 Abrasion resistance test N 2.10.9 Thermal cycling N 2.10.10 Test for Pollution Degree 1 environment and insulating compound N 2.10.11 Tests for semiconductor devices and cemented joints N 2.10.12 Enclosed and sealed parts N 3 WIRING, CONNECTIONS AND SUPPLY P 3.1 General P 3.1.1 Current rating and overcurrent protection No hazards P 3.1.2 Protection against mechanical damage No hazards P 3.1.3 Securing of internal wiring No hazards P 3.1.4 Insulation of conductors Basic insulation for inside P 3.1.5 Beads and ceramic insulators No such parts N 3.1.6 Screws for electrical contact pressure No such screw N 3.1.7 Insulating materials in electrical connections 3.1.8 Self-tapping and spaced thread screws No such screw N 3.1.9 Termination of conductors Screw and soldering P N 10 N pull test P 3.1.10 Sleeving on wiring Heat-shrinkable tube fixed on terminal P 3.2 Connection to a mains supply 3.2.1 Means of connection............................................: 3.2.1.1 Connection to an a.c. mains supply P 3.2.1.2 Connection to a d.c. mains supply N 3.2.2 Multiple supply connections N 3.2.3 Permanently connected equipment P Mains plug and appliance coupler Not such equipment P N Number of conductors, diameter of cable and conduits (mm) ....................................................... : 3.2.4 Appliance inlets Appliance inlet was approved P 3.2.5 Power supply cords Power cord set was approved P 3.2.5.1 AC power supply cords P Type ...................................................................... : 2 Rated current (A), cross-sectional area (mm ), AWG ..................................................................... : 3.2.5.2 DC power supply cords 3.2.6 Cord anchorages and strain relief TRF No. IEC60950_1B_M2 H03VV-F 3G0.75mm 2 N Detached power cord used STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N Page 15 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Mass of equipment (kg), pull (N) ......................... : Longitudinal displacement (mm) ........................... : 3.2.7 Protection against mechanical damage N 3.2.8 Cord guards N Diameter or minor dimension D (mm); test mass (g) ............................................................................... : Radius of curvature of cord (mm) .......................... : 3.2.9 Supply wiring space N 3.3 Wiring terminals for connection of external conductors N 3.3.1 Wiring terminals N 3.3.2 Connection of non-detachable power supply cords N 3.3.3 Screw terminals N 3.3.4 Conductor sizes to be connected N Rated current (A), cord/cable type, cross-sectional 2 area (mm ) ............................................................. : Wiring terminal sizes N Rated current (A), type, nominal thread diameter (mm) ..................................................................... : 3.3.6 Wiring terminal design N 3.3.7 Grouping of wiring terminals N 3.3.8 Stranded wire N 3.4 Disconnection from the mains supply P 3.4.1 General requirement P 3.4.2 Disconnect devices 3.4.3 Permanently connected equipment N 3.4.4 Parts which remain energized N 3.4.5 Switches in flexible cords N 3.4.6 Number of poles - single-phase and d.c. equipment P 3.4.7 Number of poles - three-phase equipment N 3.4.8 Switches as disconnect devices N 3.4.9 Plugs as disconnect devices 3.4.10 Interconnected equipment N 3.4.11 Multiple power sources N 3.5 Interconnection of equipment P 3.5.1 General requirements P 3.5.2 Types of interconnection circuits .......................... : 3.3.5 TRF No. IEC60950_1B_M2 Appliance coupler used Appliance coupler Appliance coupler used also SELV circuits to SELV circuits STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org P N P Page 16 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 3.5.3 ELV circuits as interconnection circuits N 3.5.4 Data ports for additional equipment P 4 PHYSICAL REQUIREMENTS P 4.1 Stability N Angle of 10 N Test force (N) .........................................................: 4.2 Mechanical strength 4.2.1 General Result - Remark < 7kg Verdict N P Metal enclosure used P Rack-mounted equipment. P 4.2.2 Steady force test, 10 N N 4.2.3 Steady force test, 30 N N 4.2.4 Steady force test, 250 N P 4.2.5 Impact test P Fall test 500g, 1.3m P Swing test 500g, 1.3m P 4.2.6 Drop test; height (mm) ...........................................: N 4.2.7 Stress relief test Metal enclosure used N 4.2.8 Cathode ray tubes No CRT. N Picture tube separately certified ............................: N 4.2.9 High pressure lamps No high pressure lamps. N 4.2.10 Wall or ceiling mounted equipment; force (N) .......: Not such equipments N 4.3 Design and construction 4.3.1 Edges and corners Edges and corners are rounded or smoothed. P 4.3.2 Handles and manual controls; force (N) ............. : No handles or controls provided N 4.3.3 Adjustable controls No adjustable controls. N 4.3.4 Securing of parts P 4.3.5 Connection by plugs and sockets P 4.3.6 Direct plug-in equipment N Torque ..................................................................: Compliance with the relevant mains plug standard ...............................................................................: N P 4.3.7 Heating elements in earthed equipment No heating elements. N 4.3.8 Batteries No battery used N - Overcharging of a rechargeable battery TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N Page 17 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict - Unintentional charging of a non-rechargeable battery N - Reverse charging of a rechargeable battery N - Excessive discharging rate for any battery N 4.3.9 Oil and grease No oil or grease. N 4.3.10 Dust, powders, liquids and gases Equipment in intended use not considered to be exposed to these. N 4.3.11 Containers for liquids or gases No container for liquid or gas. N 4.3.12 Flammable liquids .................................................: No flammable liquid. N Quantity of liquid (l) ...............................................: N Flash point (C) .....................................................: N 4.3.13 Radiation P 4.3.13.1 General N 4.3.13.2 Ionizing radiation N Measured radiation (pA/kg) ..................................: Measured high-voltage (kV) ..................................: Measured focus voltage (kV) ................................: CRT markings .......................................................: Effect of ultraviolet (UV) radiation on materials N Part, property, retention after test, flammability classification .........................................................: N 4.3.13.4 Human exposure to ultraviolet (UV) radiation .......: N 4.3.13.5 Lasers (including laser diodes) and LEDs P 4.3.13.5.1 Lasers (including laser laser diodes) N Laser class ............................................................: 4.3.13.3 4.3.13.5.2 Light emitting diodes (LEDs) 4.3.13.6 Other types ...........................................................: N 4.4 Protection against hazardous moving parts N 4.4.1 General 4.4.2 Protection in operator access areas .................... : Household and home/office document/media shredders LED used for indication only No moving parts P N N (see Annex EE) N 4.4.3 Protection in restricted access locations ............. : N 4.4.4 Protection in service access areas N 4.4.5 Protection against moving fan blades N 4.4.5.1 General N Not considered to cause pain or injury. a)………….: N TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 18 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause 4.4.5.2 Requirement + Test Result - Remark Verdict Is considered to cause pain, not injury. b) …………: N Considered to cause injury. N c) …………: Protection for users N Use of symbol or warning ……………………………: N Protection for service persons N Use of symbol or warning ……………………………: N 4.5 Thermal requirements P 4.5.1 General P 4.5.2 Temperature tests P Normal load condition per Annex L ...................... : 4.4.5.3 4.5.3 Temperature limits for materials (see appended table 4.5) P 4.5.4 Touch temperature limits (see appended table 4.5) P 4.5.5 Resistance to abnormal heat ............................... : (see appended table 4.5.5) P 4.6 Openings in enclosures 4.6.1 Top and side openings side openings P Dimensions (mm) ................................................ : Diameter: 2.30mm Bottoms of fire enclosures Metal enclosure P 4.6.2 P Construction of the bottomm, dimensions (mm) . : 4.6.3 Doors or covers in fire enclosures No doors or covers N 4.6.4 Openings in transportable equipment Not such equipment. N 4.6.4.1 Constructional design measures N Dimensions (mm) ................................................ : 4.6.4.2 Evaluation measures for larger openings N 4.6.4.3 Use of metallized parts N 4.6.5 Adhesives for constructional purposes No barrier of screen fixed by glue inside subwoofer N Conditioning temperature (C), time (weeks) ....... : 4.7 Resistance to fire P 4.7.1 Reducing the risk of ignition and spread of flame Metal enclosure P Method 1, selection and application of components wiring and materials See cl 4.7.2.2 P Method 2, application of all of simulated fault condition tests N 4.7.2 Conditions for a fire enclosure N 4.7.2.1 Parts requiring a fire enclosure N 4.7.2.2 Parts not requiring a fire enclosure P TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 19 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 4.7.3 Materials 4.7.3.1 General 4.7.3.2 Materials for fire enclosures 4.7.3.3 Materials for components and other parts outside fire enclosures 4.7.3.4 Materials for components and other parts inside fire enclosures 4.7.3.5 Materials for air filter assemblies No air filter assemblies N 4.7.3.6 Materials used in high-voltage components No high-voltage component N 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS P 5.1 Touch current and protective conductor current P 5.1.1 General 5.1.2 Configuration of equipment under test (EUT) P 5.1.2.1 Single connection to an a.c. mains supply P 5.1.2.2 Redundant multiple connections to an a.c. mains supply N 5.1.2.3 Simultaneous multiple connections to an a.c. mains supply N 5.1.3 Test circuit Figure 5A P 5.1.4 Application of measuring instrument Annex D P 5.1.5 Test procedure Between Mains and metal enclosure & terminal P 5.1.6 Test measurements P See appended table 1.5.1. P N Not require fire enclosure N N Class I equipment P P Supply voltage (V) ................................................. : 254.4V, 60Hz Measured touch current (mA) ............................... : 1.38 Max. allowed touch current (mA) .......................... : 3.5 Measured protective conductor current (mA) ....... : -- Max. allowed protective conductor current (mA) ... : -- 5.1.7 Equipment with touch current exceeding 3.5 mA N 5.1.7.1 General ................................................................. : N 5.1.7.2 Simultaneous multiple connections to the supply N 5.1.8 Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks N 5.1.8.1 Limitation of the touch current to a telecommunication network or to a cable distribution system N Supply voltage (V) ................................................. : Measured touch current (mA) ............................... : TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 20 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Max. allowed touch current (mA) .......................... : Summation of touch currents from telecommunication networks N a) EUT with earthed telecommunication ports ...... : N b) EUT whose telecommunication ports have no reference to protective earth N 5.2 Electric strength P 5.2.1 General (see appended table 5.2) P 5.2.2 Test procedure (see appended table 5.2) P 5.3 Abnormal operating and fault conditions 5.3.1 Protection against overload and abnormal operation 5.3.2 Motors 5.3.3 Transformers (see appended Annex C) P 5.3.4 Functional insulation .............................................. : Result see appened table 5.3 P 5.3.5 Electromechanical components No such component N 5.3.6 Audio amplifiers in ITE .......................................... : No such component N 5.3.7 Simulation of faults (see appended table 5.3) P 5.3.8 Unattended equipment No such equipment N 5.3.9 Compliance criteria for abnormal operating and fault conditions 5.3.9.1 During the tests No fire, no molten metal, no enclosure deformation and no temperature exceeding those in table 5D P 5.3.9.2 After the tests No any hazards P 6 CONNECTION TO TELECOMMUNICATION NETWORKS P 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment P 6.1.1 Protection from hazardous voltages P 6.1.2 Separation of the telecommunication network from earth P 6.1.2.1 Requirements N Supply voltage (V) ................................................ : Current in the test circuit (mA) ............................ : 6.1.2.2 Exclusions ............................................................ : P 6.2 Protection of equipment users from overvoltages on telecommunication networks N 5.1.8.2 TRF No. IEC60950_1B_M2 P (see appended table 5.3) P N P STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 21 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark 6.2.1 Separation requirements N 6.2.2 Electric strength test procedure N 6.2.2.1 Impulse test N 6.2.2.2 Steady-state test N 6.2.2.3 Compliance criteria N 6.3 Protection of the telecommunication wiring system from overheating N Max. output current (A) ......................................... : No telecommunication wiring system Verdict Current limiting method ........................................ : 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS N 7.1 General N 7.2 Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment N 7.3 Protection of equipment users from overvoltages on the cable distribution system N 7.4 Insulation between primary circuits and cable distribution systems N 7.4.1 General N 7.4.2 Voltage surge test N 7.4.3 Impulse test N A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE N A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see 4.7.3.2) N A.1.1 Samples ................................................................ : Wall thickness (mm) ............................................. : A.1.2 Conditioning of samples; temperature (C) .......... : N A.1.3 Mounting of samples ............................................ : N A.1.4 Test flame (see IEC 60695-11-3) N Flame A, B, C or D ............................................... : A.1.5 Test procedure N A.1.6 Compliance criteria N Sample 1 burning time (s) ..................................... : Sample 2 burning time (s) ..................................... : TRF No. IEC60950_1B_M2 No cable distribution system STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 22 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Sample 3 burning time (s) ..................................... : A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see 4.7.3.2 and 4.7.3.4) N A.2.1 Samples, material ................................................. : Wall thickness (mm) ............................................. : A.2.2 Conditioning of samples; temperature (°C) .......... : N A.2.3 Mounting of samples ............................................ : N A.2.4 Test flame (see IEC 60695-11-4) N Flame A, B or C .................................................... : A.2.5 Test procedure N A.2.6 Compliance criteria N Sample 1 burning time (s) ..................................... : Sample 2 burning time (s) ..................................... : Sample 3 burning time (s) ..................................... : Alternative test acc. to IEC 60695-11-5, cl. 5 and 9 N Sample 1 burning time (s) ..................................... : Sample 2 burning time (s) ..................................... : Sample 3 burning time (s) ..................................... : A.3 Hot flaming oil test (see 4.6.2) N A.3.1 Mounting of samples N A.3.2 Test procedure N A.3.3 Compliance criterion N B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and 5.3.2) N B.1 General requirements N A.2.7 (see appended table 1.5.1) Position ................................................................. : Manufacturer ........................................................ : Type ..................................................................... : Rated values ....................................................... : B.2 Test conditions N B.3 Maximum temperatures N B.4 Running overload test N B.5 Locked-rotor overload test N Test duration (days) ............................................. : Electric strength test: test voltage (V) .................. : TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 23 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test B.6 Running overload test for d.c. motors in secondary circuits P B.6.1 General N B.6.2 Test procedure N B.6.3 Alternative test procedure N B.6.4 Electric strength test; test voltage (V) .................. : N B.7 Locked-rotor overload test for d.c. motors in secondary circuits B.7.1 General N B.7.2 Test procedure N B.7.3 Alternative test procedure N B.7.4 Electric strength test; test voltage (V) ................. : N B.8 Test for motors with capacitors N B.9 Test for three-phase motors N B.10 Test for series motors N Operating voltage (V) ........................................... : ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3) P C Result - Remark (see appended table 5.3) Verdict P Position ................................................................. : ETD34/TPT150A Manufacturer ........................................................ : (see appended tabel 1.5.1) Type ..................................................................... : (see appended tabel 1.5.1) Rated values ....................................................... : (see appended tabel 1.5.1) Method of protection ............................................. : Inherent C.1 Overload test (see appended tabel 5.3) P C.2 Insulation Protection from displacement of windings ............ : P Bobbin, insulation tube, insulaton tape P D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see 5.1.4) P D.1 Measuring instrument P D.2 Alternative measuring instrument N E ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13) N F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10 and Annex G) P TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 24 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES N G.1 Clearances N G.1.1 General N G.1.2 Summary of the procedure for determining minimum clearances N G.2 Determination of mains transient voltage (V) N G.2.1 AC mains supply .................................................. : N G.2.2 Earthed d.c. mains supplies ................................. : N G.2.3 Unearthed d.c. mains supplies ............................. : N G.2.4 Battery operation .................................................. : N G.3 Determination of telecommunication network transient voltage (V) ............................................. : N G.4 Determination of required withstand voltage (V) N G.4.1 Mains transients and internal repetitive peaks ..... : N G.4.2 Transients from telecommunication networks ..... : N G.4.3 Combination of transients N G.4.4 Transients from cable distribution systems N G.5 Measurement of transient voltages (V) N a) Transients from a mains supply N For an a.c. mains supply N For a d.c. mains supply N b) Transients from a telecommunication network N G.6 Determination of minimum clearances ................. : N H ANNEX H, IONIZING RADIATION (see 4.3.13) N J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) N Metal(s) used ....................................................... : K ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8) N K.1 Making and breaking capacity N K.2 Thermostat reliability; operating voltage (V) ......... : N K.3 Thermostat endurance test; operating voltage (V) .............................................................................. : N K.4 Temperature limiter endurance; operating voltage (V) ......................................................................... : N K.5 Thermal cut-out reliability N TRF No. IEC60950_1B_M2 Result - Remark STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Verdict Page 25 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test K.6 Stability of operation N L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2) P L.1 Typewriters N L.2 Adding machines and cash registers N L.3 Erasers N L.4 Pencil sharpeners N L.5 Duplicators and copy machines N L.6 Motor-operated files N L.7 Other business equipment M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N M.1 Introduction N M.2 Method A N M.3 Method B N M.3.1 Ringing signal N M.3.1.1 Frequency (Hz) ..................................................... : M.3.1.2 Voltage (V) ........................................................... : M.3.1.3 Cadence; time (s), voltage (V) ............................. : M.3.1.4 Single fault current (mA) ...................................... : M.3.2 Tripping device and monitoring voltage ............... : N M.3.2.1 Conditions for use of a tripping device or a monitoring voltage N M.3.2.2 Tripping device N M.3.2.3 Monitoring voltage (V) .......................................... : N N ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1, 7.3.2, 7.4.3 and Clause G.5) N N.1 ITU-T impulse test generators N N.2 IEC 60065 impulse test generator N P ANNEX P, NORMATIVE REFERENCES Q ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1) P - Preferred climatic categories ............................. : P TRF No. IEC60950_1B_M2 Result - Remark See condition in appended table 1.6.2 (see appended tabel 1.5.1) Varistor was apploved STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Verdict P Page 26 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict - Maximum continuous voltage ............................ : P - Combination pulse current ................................. : P Body of the VDR Test according to IEC60695-11-5 ........................ : P Body of the VDR. Flammability class of material ( min V-1) ............. : P R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES N R.1 Minimum separation distances for unpopulated coated printed boards (see 2.10.6.2) N R.2 Reduced clearances (see 2.10.3) N S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) N S.1 Test equipment N S.2 Test procedure N S.3 Examples of waveforms during impulse testing N T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2) N U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see 2.10.5.4) N V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) N V.1 Introduction N V.2 TN power distribution systems N W ANNEX W, SUMMATION OF TOUCH CURRENTS N W.1 Touch current from electronic circuits N W.1.1 Floating circuits N W.1.2 Earthed circuits N W.2 Interconnection of several equipments N W.2.1 Isolation N W.2.2 Common return, isolated from earth N W.2.3 Common return, connected to protective earth N TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 27 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause C.1) N X.1 Determination of maximum input current N X.2 Overload test procedure N Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) N Y.1 Test apparatus ......................................................: N Y.2 Mounting of test samples ......................................: N Y.3 Carbon-arc light-exposure apparatus ...................: N Y.4 Xenon-arc light exposure apparatus .....................: N Z ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2) P AA ANNEX AA, MANDREL TEST (see 2.10.5.8) N BB ANNEX BB, CHANGES IN THE SECOND EDITION CC ANNEX CC, Evaluation of integrated circuit (IC) current limiters N CC.1 General N CC.2 Test program 1 ......................................................: N CC.3 Test program 2 ......................................................: N CC.4 Test program 3 ......................................................: N CC.5 Compliance ...........................................................: N DD ANNEX DD, Requirements for the mounting means of rack-mounted equipment N DD.1 General N DD.2 Mechanical strength test, variable N………………..: N DD.3 Mechanical strength test, 250N, including end stops……………………………………………………: N DD.4 Compliance……………………………………………: N EE ANNEX EE, Household and home/office document/media shredders N EE.1 General N EE.2 Markings and instructions N Use of markings or symbols…………………………: N TRF No. IEC60950_1B_M2 Result - Remark STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Verdict Page 28 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Information of user instructions, maintenance and/or servicing instructions…………………………: N EE.3 Inadvertent reactivation test…………………………: N EE.4 Disconnection of power to hazardous moving parts: N Use of markings or symbols…………………………: N Protection against hazardous moving parts N Test with test finger (Figure 2A) ……………………: N Test with wedge probe (Figure EE1 and EE2) ……: N EE.5 TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 29 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark 1.5.1 TABLE: List of critical components Verdict P Object/part No. Manufacturer/ trademark Type/ model Technical data Standard (Edition / year) Mark(s) of 1 conformity ) AC plug Shenzhen HongPu Electron Co., Ltd. XTH-005 16A, 250V~ VDE 0620-1 VDE 40026370 Shenzhen Yuxin Wire YX-201 & Cable Co., Ltd. 16A, 250V~ VDE 0620-1 VDE 40001445 Shenzhen Baohing Electric Wire & Cable Manufacture Co., Ltd. H03VV-F 3G0.75mm 2 HD 21.5 S3+A1+A2 VDE 103727 Shenzhen Yuxin Wire H03VV-F & Cable Co., Ltd. 3G0.75mm 2 HD 21.5 S3+A1+A2 VDE 40012386 Shenzhen HongPu Electron Co., Ltd. 10A, 250V~ EN 60320-1 VDE 40025516 10A, 250V~ EN 60320-1 VDE 40035945 EN 60320-1 VDE 40025582 Power cord AC connector XTH-021 Shenzhen Yuxin Wire YX-210 & Cable Co., Ltd. Appliance Inlet Tecx-Unions Technology Corporation Primary lead wire & Earth wire Heat shrinkable tube Insulation sheet on PCB White glue on PCB TU-301-AP 10A, 250VAC Zhongshan Dongfeng 1015 Zhoushishenlong Electronic Wire Co., Ltd. 105C, 600V, 18AWG, VW-1 UL 758 UL E257280 Cable-Net Industries Ltd. 1015 105C, 600V, 18AWG, VW-1 UL 758 UL E198417 Various 1015 105C, 600V, 18AWG, VW-1 UL 758 UL Dongguan Salipt Co., Ltd. SALIPT S901-300 300V, 125C, VW-1 UL 224 UL E209436 Dongguan Quantai Industrial Co., Ltd. T-2 600V, 125C, VW-1 UL 224 UL E227336 Various Various 300V, 125C, VW-1 UL 224 UL Mianyang Longhua Film Co., Ltd. PC-770, PC, V-0, 80C, PC-770F, Min. 0.4mm PC-770F-A UL 94, UL 746 UL E254551 Suzhou Omay Optical SE42, Materials Co., Ltd. SE42B PC, V-0, 80C, Min. 0.4mm UL 94, UL 746 UL E249605 Various Various PC, V-0, 80C, Min. 0.4mm UL 94, UL 746 UL Shen Zhen Bonic Science & Technology Co., Ltd. Various V-0, Min.130C UL 94, UL 746 UL E254560 TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 30 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Object/part No. Manufacturer/ trademark Type/ model Technical data Standard (Edition / year) Mark(s) of 1 conformity ) AC Connector CN1 Zhejiang Jinda Electronics Co., Ltd. 3.96T-02 V-0, 250Vac, 7A UL 1977 UL E237523 Shenzhen Yong Feng Ying Electronic Co., Ltd. CS-1120 V-0, 250Vac, 7A UL 1977 UL E241915 Shanghai Yueshen Electronic Co., Ltd. YSF6 V-0, 250Vac, 7A UL 1977 UL E204074 Dongguan Better 932 Electronics Technology Co., Ltd. T5AL250Vac IEC 60127-1 IEC 60127-3 VDE 40033369 Shenzhen Lanson Electronics Co. Ltd. SMT T5AL250Vac IEC 60127-1 IEC 60127-3 VDE 40013102 Cooper Bussmann LLC SS-5 T5AL250Vac IEC 60127-1 IEC 60127-3 VDE 40015513 Dongguan Hongda Electronic Technology Co., Ltd. 2009 T5AL250Vac IEC 60127-1 IEC 60127-3 VDE 40028260 Various Various T5AL250Vac IEC 60127-1 IEC 60127-3 VDE Centra Science Corp. CNR14D471K 470Vac, 85C IEC61051-1 IEC61051-2 VDE 40008220 Lien Shun Electronics Co., Ltd. 14D471K 470Vac, 85C IEC61051-1 IEC61051-2 VDE 40005858 Thinking Electronic Industrial Co., Ltd. TVR14471- 470Vac, 85C D IEC61051-1 IEC61051-2 VDE 40021243 Thinking Electronic Industrial Co., Ltd. TVR14471 470Vac, 85C IEC61051-1 IEC61051-2 VDE 005944 Brightking (Shenzhen) Co., Ltd. 471KD14 470Vac, 85C IEC61051-1 IEC61051-2 VDE 40027827 Shaanxi Huaxing electronic group Co., Ltd. MYG20G1 4K471 470Vac, 85C IEC61051-1 IEC61051-2 VDE 40018747 Shantou High-New Technology Dev. Zone Songtian Enterprise Co., Ltd. STE14D471K 470Vac, 85C IEC61051-1 IEC61051-2 VDE 40023049 Guangdong South Hongming Electronic Science and Technology Co., Ltd. F 3300pF 250Vac, 125°C IEC 60384-14 VDE 40036393 Shantou High-New Technology Dev. Zone Songtian Enterprise Co., Ltd. CD 3300pF 250Vac, 125°C IEC 60384-14 VDE 40025754 Fuse F1 Varistor V1 Y1 capacitor CY3 TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 31 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Object/part No. Y2 capacitor CY4,CY5 Y2 capacitor CY1,CY2, X2 capacitor CX1, CX2 Requirement + Test Result - Remark Verdict Manufacturer/ trademark Type/ model Technical data Standard (Edition / year) Shaanxi Huaxing Electronic Development Co. Ltd. CT7Y1 3300pF 400Vac, 125°C IEC 60384-14 VDE 40015542 Shenzhen Teruixiang Electronic Co, Ltd. TY-Series (TYB,TYE, TYF) 3300pF 400Vac, 125°C IEC 60384-14 VDE 40023136 Dongguan Easy-gather Electronic Co., Ltd. DCF 3300pF 400Vac, 125°C IEC 60384-14 VDE 40022942 Jya-Nay Co., Ltd. JN 3300pF, Min.250Vac, 125°C EN 60384-14 Guangdong South Hongming Electronic Science and Technology Co., Ltd. F 3300pF 250Vac, 125°C IEC 60384-14 VDE 40036393 Shantou High-New Technology Dev. Zone Songtian Enterprise Co., Ltd. CE 3300pF 250Vac, 125°C IEC 60384-14 VDE 40025748 Shaanxi Huaxing Electronic Development Co. Ltd. CT7Y2 3300pF 400Vac, 125°C IEC 60384-14 VDE 40032125 Dongguan Easy-gather Electronic Co., Ltd. DCF 3300pF 250Vac, 125°C IEC 60384-14 VDE 40015758 Guangdong South Hongming Electronic Science and Technology Co., Ltd. F 2200pF 250Vac, 125°C IEC 60384-14 VDE 40036393 Shantou High-New Technology Dev. Zone Songtian Enterprise Co., Ltd. CE 2200pF 250Vac, 125°C IEC 60384-14 VDE 40025748 Shaanxi Huaxing Electronic Development Co. Ltd. CT7Y2 2200pF 400Vac, 125°C IEC 60384-14 VDE 40032125 Dongguan Easy-gather Electronic Co., Ltd. DCF 2200pF 250Vac, 125°C IEC 60384-14 VDE 40015758 Tenta Electric Industrial MEX Co. Ltd. 0.47μF 275Vac IEC 60384-14 VDE 119119 Dain Electronics Co., Ltd. MPX/NPX/ MEX 0.47μF 275Vac IEC 60384-14 VDE 40018798 Shantou High-New Technology Dev. Zone Songtian Enterprise Co., Ltd. MPX 0.47μF 275Vac IEC 60384-14 VDE 40034679 TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Mark(s) of 1 conformity ) TÜV Rheinland Cert. No.: 69242987 Page 32 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Object/part No. Requirement + Test Result - Remark Verdict Manufacturer/ trademark Type/ model Technical data Standard (Edition / year) Shenzhen Su Rong Capacitors Co., Ltd. MPX/MKP 0.47μF 275Vac IEC 60384-14 VDE 40008924 Dongguan Easy-gather Electronic Co., Ltd. MKP-X2 0.47μF 275Vac IEC 60384-14 VDE 40022258 Nanjing Shiheng Electronics Co., Ltd. MF7210D11 10Ω,3A IEC60950 UL1434 UL E241319 Thinking Electronic Industrial Co., Ltd. SCK-103 10Ω,3A IEC60950 UL1434 UL E138827 EL817 V Dti≥0.4mm, Cl≥6.0mm, Cr≥7.5mm, 110°C EN 60747-5-5 VDE 132249 Bright Led Electronics Corp. BPC-817 IEC 60747-5Dti≥0.4mm, Cr=8.0mm, Cl=7.6mm, 2 100°C Lite-On Technology Corporation LTV-817 Dti>0.5mm, Int. Cr>6.0mm, Ext. Cr>7.5mm, 100C EN 60747-5-2 VDE 40015248 Shenzhen Orient Components Co., Ltd. ORPC-817 Dti≥0.4mm, Cl≥6.0mm, Cr≥7.5mm, 100°C EN 60747-5-2 VDE 40029733 Inductors LF1, LF2 Shenzhen Topow Electronics Co., Ltd. T18*10*7 24mH EN 60950-1 Tested within appliance Winding of LF1, LF2 Pacific Electric Wire & Cable (Shenzhen) Co., Ltd. UEW/U 130°C UL1446 UL E201757 Insulation tape of LF1, LF2 Jingjiang Yahua Pressure Sensitive Glue Co., Ltd. PZ CZ 130°C UL 510 UL E165111 Inductors L1 Shenzhen Topow Electronics Co., Ltd. T68-26A 160μH EN 60950-1 Tested within appliance Winding of L1 Pacific Electric Wire & Cable (Shenzhen) Co., Ltd. UEW/U 130°C UL1446 UL E201757 Transformer T1 Shenzhen Topow Electronics Co., Ltd. EI2820/TP T150A Primary: N1: Φ0.1mm*40P*44TS Secondary: N4: Φ0.3mm*1P*5TS EN 60950-1 Tested within appliance Bobbin of T1 Chang Chun Plastics Co., Ltd. T375J V-0, 150°C UL 746, UL 94 UL E59481 Insulation tape of T1 Jingjiang Yahua Pressure Sensitive Glue Co., Ltd. PZ CZ 130°C UL 510 UL E165111 UEW/U 130°C UL 1446 UL E201757 Thermistor TR1 Ophtocoupler Everlight Electronics U1 Co., Ltd. Winding of T1 Pacific Electric Wire & TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Mark(s) of 1 conformity ) VDE 40007240 Page 33 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Object/part No. Manufacturer/ trademark Result - Remark Verdict Type/ model Technical data Standard (Edition / year) Mark(s) of 1 conformity ) BC-346A 200°C UL 1446 UL E317427 Cable (Shenzhen) Co., Ltd. Varnish of T1 John C Dolph Co. Insulating tube of T1 Great Holding Industrial TFT Co., Ltd. 300V, 200°C UL 224 UL E156256 Transformer T2 Shenzhen Topow Electronics Co., Ltd. Primary: N1: Φ0.1mm*40P*44TS N4: Φ0.3mm*1P*4TS Secondary: N2: Φ0.1mm*50P*12TS N3: Φ0.1mm*50P*12TS EN 60950-1 Tested within appliance ETD34/TP T150A Class B Bobbin of T2 Chang Chun Plastics Co., Ltd. T375J V-0, 150°C UL 746, UL 94 UL E59481 Insulation tape of T2 Jingjiang Yahua Pressure Sensitive Glue Co., Ltd. PZ 130°C UL 510 UL E165111 UEW/U 130°C UL 1446 UL E201757 Winding of T2 Pacific Electric Wire & Cable (Shenzhen) Co., Ltd. Insulating tube of T2 Great Holding Industrial TFT Co., Ltd. 300V, 200°C UL 224 UL E156256 Varnish of T2 John C Dolph Co. BC-346A 200°C UL 1446 UL E317427 Power board Sources Merge Industrial Ltd. TCL1008F R V-0, 130°C UL 94, UL 746 UL E74729 Boluo Eversun Electronics Plant YY-D V-0, 130°C UL 94, UL 746 UL E250664 Various Various V-0, 130°C UL 94, UL 746 UL Goldenmax International Technology (Zhuhai) Ltd. Various V-0, 130°C UL 94, UL 746 UL E330731 Various Various V-0, 130°C UL 94, UL 746 UL PCB Other PCB Supplementary information:/ TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 34 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 1.6.2 Result - Remark Verdict P TABLE: Electrical data (in normal conditions) Cond. U (V) Hz I (A) Irated (A) P (W) Fuse # Ifuse (A) Condition/status 01 90.0 50 1.25 -- 113.0 F1 1.25 Normal operation 02 100.0 50 1.13 2.2 112.4 F1 1.13 03 240.0 50 0.533 2.2 109.4 F1 0.533 04 254.4 50 0.543 -- 110.2 F1 0.543 05 90.0 60 1.24 -- 112.0 F1 1.24 06 100.0 60 1.12 2.2 112.2 F1 1.12 07 240.0 60 0.525 2.2 108.6 F1 0.525 08 254.4 60 0.540 -- 109.2 F1 0.540 Supplementary information: -P 2.1.1.5 c) 1) TABLE: max. V, A, VA test Voltage (rated) (V) Current (rated) (A) Voltage (max.) (V) Current (max.) (A) VA (max.) (VA) -- -- 52.87Vd.c. 3.86 203.6 Supplementary information: Output of power supply PCB. 2.1.1.5 c) 2) N TABLE: stored energy Capacitance C (µF) Voltage U (V) Energy E (J) -- -- -- supplementary information: 2.2 TABLE: evaluation of voltage limiting components in SELV circuits Component (measured between) Output of power supply PCB Fault test performed on voltage limiting components S-C diode D12 max. voltage (V) (normal operation) V peak V d.c. -- 52.87 Voltage Limiting Components -- Voltage measured (V) in SELV circuits (V peak or V d.c.) Unit shut down, no output U=0 Remark: Output of power supply PCB TRF No. IEC60950_1B_M2 P STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 35 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark 2.4.2 TABLE: limited current circuit measurement Location Verdict P Voltage (V) Current (mA) Freq. (Hz) Limit (mA) Comments 6.94 3.47 248K 173.6 CY3: 3300PF Between Y capacitor CY3 Remark: 2.5 N TABLE: limited power sources Circuit output tested: Output of power supply PCB Measured Uoc (V) with all load circuits disconnected: Isc (A) -- VA Meas. Limit Meas. Limit -- -- -- -- supplementary information: 2.10.2 P Table: working voltage measurement Location RMS voltage (V) Peak voltage (V) Comments Transformer T2 pin 1- pin 8 240 339 -- Transformer T2 pin 1- pin 9 240 339 -- Transformer T2 pin 1- pin 10 240 339 -- Transformer T2 pin 2- pin 8 240 339 -- Transformer T2 pin 2- pin 9 240 339 -- Transformer T2 pin 2- pin 10 240 339 -- Transformer T2 pin 5- pin 8 246 340 -- Transformer T2 pin 5- pin 9 240 339 -- Transformer T2 pin 5- pin 10 240 339 -- Transformer T2 pin 6- pin 8 311 448 Max. RMS & Peak of T2 Transformer T2 pin 6- pin 9 240 339 -- Transformer T2 pin 6- pin 10 242 408 -- Optocoupler U1 pin 1- pin 3 240 339 -- Optocoupler U1 pin 1- pin 4 240 339 Max. RMS & Peak of U1 Optocoupler U1 pin 2- pin 3 240 339 -- Optocoupler U1 pin 2- pin 4 240 339 -- Y capacitor CY3 pin 1- pin 2 240 339 Max. RMS & Peak of CY3 TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 36 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict supplementary information: P 2.10.3 and TABLE: Clearance and creepage distance measurements 2.10.4 Clearance (cl) and creepage distance (cr) at/of/between: U peak (V) U r.m.s. (V) Required cl (mm) cl (mm) Required cr (mm) cr (mm) L and N 339 240 1.5 2.4 2.5 3.8 Two pins of F1 339 240 2.0 2.1 2.5 3.2 Live part and earth 339 240 2.0 3.2 2.5 3.2 Two pins of Capacitor CY1 339 240 2.0 4.8 2.5 4.8 Two pins of Capacitor CY2 339 240 2.0 3.2 2.5 3.2 Two pins of Capacitor CY3 339 240 4.0 7.9 5.0 7.9 Two pins of Capacitor CY4 339 240 2.0 4.2 2.5 4.2 Two pins of Capacitor CY5 339 240 2.0 4.2 2.5 4.2 Optocoupler U1 (Pri.-Sec.) 339 240 4.0 7.9 5.0 7.9 Transformer T2 (Pri.-Sec.) on PCB 448 311 4.3 10.7 6.3 10.7 Transformer T2 (Pri.-Sec.) 448 311 4.3 8.9 6.3 8.9 Live part and Sec. 339 240 2.0 12.2 2.5 12.2 Live part and metal enclosure 339 240 2.0 3.2 2.5 3.2 Supplementary information: -2.10.5 P TABLE: Distance through insulation measurements Distance through insulation (DTI) at/of: U peak (V) U rms (V) Test voltage (V) Required DTI (mm) DTI (mm) Transformer bobbin 448 311 3000 0.4 0.8 Optocoupler U1 339 240 3000 0.4 >0.4 Supplementary information: -- TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 37 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 4.3.8 TABLE: Batteries Result - Remark Verdict N The tests of 4.3.8 are applicable only when appropriate battery data is not available No battery N Is it possible to install the battery in a reverse polarity position? Non-rechargeable batteries Discharging Meas. current Manuf. Specs. Max. current during normal condition -- -- Max. current during fault condition -- -- Unintentional charging N Rechargeable batteries Charging Meas. current Discharging Manuf. Specs. Meas. current Manuf. Specs. Reversed charging Manuf. Specs. -- Meas. current -- -- -- -- -- Test results: -- Verdict - Chemical leaks -- N - Explosion of the battery -- N - Emission of flame or expulsion of molten metal -- N - Electric strength tests of equipment after completion of tests -- N Remark: -- TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 38 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 4.3.8 TABLE: Batteries Result - Remark N Battery category........................................... : -- Manufacturer ............................................... : -- Type / model ................................................ : -- Voltage ........................................................ : -- Capacity....................................................... : -- Tested and Certified by (incl. Ref. No.) ....... : -- Circuit protection diagram: MARKINGS AND INSTRUCTIONS (1.7.12, 1.7.15) Location of replaceable battery -- Language(s) …………………………………….: -- Close to the battery …………………………….: -- In the servicing instructions ……………………: -- In the operating instructions …………………..: -- TRF No. IEC60950_1B_M2 Verdict STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 39 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 4.5.1 TABLE: maximum temperatures Result - Remark Verdict P Supply voltage (V) ............................90.0 254.4 Ambient Tmin (C) ..............................24.0 24.4 Ambient Tmax (C) .............................24.5 24.8 Maximum measured temperature T of part/at: T (C) Allowed Tmax (C) No. 05 No. 04 Y- Capacitor CY1 61.3 47.4 125+24-40=109 Varistors V1 65.2 52.2 85+24-40=69 X-Capacitor CX1 71.8 54.9 100+24-40=84 Inductors LT1 winding 78.9 56.1 110+24-40=94 Inductors LT2 winding 80.8 55.4 110+24-40=94 X-Capacitor CX2 79.0 56.5 100+24-40=84 PCB near BD1 81.1 59.6 130+24-40=114 PCB near D2 80.8 63.1 130+24-40=114 Capacitor C2 73.1 61.1 105+24-40=89 Inductors L1 winding 76.0 58.7 110+24-40=94 PCB near Q1 67.3 61.6 130+24-40=114 Transformer T1 bobbin 88.4 66.7 Reference Transformer T1 winding 89.1 67.9 110+24-40=94 Y- Capacitor CY3 54.5 53.0 125+24-40=109 Optocoupler U1 58.3 57.0 100+24-40=84 Transformer T2 Pri. winding 75.1 73.7 110+24-40=94 Transformer T2 Sec. winding 76.4 76.2 110+24-40=94 Transformer T2 bobbin 75.7 75.4 Reference Capacitor C28 64.7 64.0 105+24-40=89 PCB near D12 64.1 64.2 130+24-40=114 PCB near IC (signal PCB) 53.5 52.4 130+24-40=114 Inductors L6 winding 69.3 67.3 110+24-40=94 Capacitor C1 58.8 57.4 105+24-40=89 Internal wire of Pri. 62.9 50.8 105+24-40=89 Internal wire of Sec. 52.9 52.2 80+24-40=64 Power supply cord 26.7 26.6 75+24-40=59 Metal enclosure 42.0 37.4 70+24-40=54 Inlet surface 36.0 34.4 85+24-40=69 TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 40 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Heat-sink 93.0 65.1 Reference Network terminal 37.4 37.1 70+24-40=54 Temperature T of winding: t1 (°C) -- R1 () t2 (°C) R2 () Allowed Tmax (C) Insulation class -- -- -- -- -- Supplementary information: * The winding permitted temperature rise would be reduced 10K while the temperature rise measured for thermal-coupler method. Allowed Tmax=Tmax+Tamb-Tma, Tamb=24C, Tma=40C. The max operated temperature is 40C which is specified by manufacturer 4.5.5 TABLE: Ball pressure test of thermoplastic parts P Allowed impression diameter (mm) ..................... : 2 mm Part Test temperature Impression diameter (mm) (C) Bobbin of T1 125 1.03 Bobbin of T2 125 0.87 AC terminal CN1 125 1.14 Supplementary information: -4.7 P TABLE: Resistance to fire Part Manufacturer of material Type of material Thickness Flammability (mm) class Evidence Bobbin of T1 Chang Chun Plastics Co., Ltd. T375J 3.0 V-0 UL E59481 Bobbin of T2 Chang Chun Plastics Co., Ltd. T375J 0.9 V-0 UL E59481 AC terminal CN1 Zhejiang Jinda Electronics Co., Ltd. 3.96T-02 2.46 V-0 UL E237523 Material of supply PCB Various Various 1.6 V-0 UL Supplementary information: -5.1 P TABLE: touch current measurement Measured between: L/N and metal enclosure Measured (mA) Limit (mA) 1.38 3.5 Comments/conditions -- supplementary information: Input voltage: 254.4V, 60Hz TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 41 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 5.2 Result - Remark Verdict P TABLE: Electric strength tests, impulse tests and voltage surge tests Test voltage applied between: Voltage shape (AC, DC, impulse, surge) Test voltage (V) Breakdown Yes / No Between L-N and metal enclosure & terminal AC 1500 No Transformer T2 primary and secondary AC 3000 No 1 layer insulation tape of transformer AC 3000 No Between L and N without fuse F1 AC 1500 No Supplementary information: -5.3 P TABLE: Fault condition tests Ambient temperature (C) .................................... : 21.5-23.4 Power source for EUT: Manufacturer, model/type, output rating ......................................................... : -- Component No. Fault Supply voltage (V) Test time Fuse # Fuse current (A) T2 output O-L 254.4V 300 mins F1 0.907 T2 output S-C 254.4V 30mins F1 0.130↔ 0.127 No hazard occurred and no high temperature occurred. Unit shut down. D2 Pin 2-3 S-C 254.4V 30mins F1 0.133↔ 0.130 No hazard occurred and no high temperature occurred. Unit shut down. D2 Pin 1-2 S-C 254.4V 30mins F1 0.143↔ 0.132 No hazard occurred and no high temperature occurred. Unit shut down. Capacitor C20 S-C 254.4V 30mins F1 0.132↔ 0.130 No hazard occurred and no high temperature occurred. Unit shut down. Q6 Pin 1-2 S-C 254.4V 1s F1 0 No hazard occurred and no high temperature occurred. Fuse F1 opened immediately. Q5 Pin 2-3 S-C 254.4V 1s F1 0 No hazard occurred and no high temperature occurred. Fuse F1 opened immediately. TRF No. IEC60950_1B_M2 Observation No hazard occurred and no high temperature occurred. The max. temperature of L1 is 75.3C. The max. temperature of T1 is 89.7C. The max. temperature of T2 is 108.8C. The max. over-load current is 3.9A, over 3.9A, the unit shut down. STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 42 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Capacitor C2 S-C 254.4V 1s F1 0 No hazard occurred and no high temperature occurred. Fuse F1 opened immediately. Q2 S-C 254.4V 1s F1 0 No hazard occurred and no high temperature occurred. Fuse F1 opened immediately. BD1 S-C 254.4V 1s F1 0 No hazard occurred and no high temperature occurred. Fuse F1 opened immediately. Supplementary information: S-C is abbreviation of shorted- circuit. O-L is abbreviation of over-load. The limit of T1 and T2 winding: 165+21.5-40=146.5C C.2 TABLE: transformers Loc. Tested insulation T2 Pri. to Sec. Reinforced insulation Loc. T2 Pri. to Sec. P Working voltage peak / V Working voltage rms / V (2.10.2) (5.2) (2.10.3) Required creepage distance / mm (2.10.4) (2.10.2) 3000Vac 4.3 6.3 * Tested insulation Test voltage/ V Measured clearance / mm Measured creepage dist./ mm Measured distance thr. insul. / mm; number of layers Reinforced insulation 3000Vac 8.9 8.9 0.87mm 2 layers 448 311 Required electric strength Required clearance / mm supplementary information: TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Required distance thr. insul. (2.10.5) Page 43 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause C.2 Requirement + Test Result - Remark TABLE: transformers Transformer TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Verdict P Page 44 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 – CENELEC COMMON MODIFICATIONS IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN) Clause Contents (A2:2013) General General (A1:2010) General (A2:2013) Requirement + Test Result - Remark Verdict Clauses, subclauses, notes, tables and figures which are additional to those in IEC60950-1 and it´s amendmets are prefixed “Z” P Add the following annexes: P Annex ZA (normative) Normative references to international publications with their corresponding European publications Annex ZB (normative) Annex ZD (informative) Special national conditions IEC and CENELEC code designations for flexible cords Delete all the “country” notes in the reference document (IEC 60950-1:2005) according to the following list: 1.4.8 Note 21.5.1 Note 2 & 3 1.5.7.1 Note 1.5.8 Note 2 1.5.9.4 Note 1.7.2.1 Note 4, 5 & 6 2.2.3 Note 2.2.4 Note 2.3.2 Note 2.3.2.1 Note 2 2.3.4 Note 2 2.6.3.3 Note 2 & 3 2.7.1 Note 2.10.3.2 Note 2 2.10.5.13 Note 3 3.2.1.1 Note 3.2.4 Note 3. 2.5.1 Note 2 4.3.6 Note 1 & 2 4.7 Note 4 4.7.2.2 Note 4.7.3.1Note 2 5.1.7.1 Note 3 & 4 5.3.7 Note 1 6 Note 2 & 5 6.1.2.1 Note 2 6.1.2.2 Note 6.2.2 Note 6.2.2.1 Note 2 6.2.2.2 Note 7.1 Note 3 7.2 Note 7.3 Note 1 & 2 G.2.1 Note 2 Annex H Note 2 Delete all the “country” notes in the reference document (IEC 609501:2005/A1:2010) according to the following list: 1.5.7.1 Note 6.2.2.1 Note 2 6.1.2.1 EE.3 P P Note 2 Note Delete all the “country” notes in the reference document (IEC 609501:2005/A2:2013) according to the following list: 2.7.1 Note * 2.10.3.1 Note 2 P 6.2.2. Note * Note of secretary: Text of Common Modification remains unchanged. 1.1.1 Replace the text of NOTE 3 by the following. (A1:2010) NOTE 3 The requirements of EN 60065 may also be used to meet safety requirements for multimedia equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. For television sets EN 60065 applies. TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org P Page 45 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN) Clause 1.3.Z1 Requirement + Test Result - Remark Add the following subclause: Not such equiipment. Verdict N 1.3.Z1 Exposure to excessive sound pressure The apparatus shall be so designed and constructed as to present no danger when used for its intended purpose, either in normal operating conditions or under fault conditions, particularly providing protection against exposure to excessive sound pressures from headphones or earphones. NOTE Z1 A new method of measurement is described in EN 50332-1, Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 1: General method for “one package equipment”, and in EN 50332-2, Sound system equipment: Headphones and earphones associated with portable audio equipment Maximum sound pressure level measurement methodology and limit considerations - Part 2: Guidelines to associate sets with headphones coming from different manufacturers. (A12:2011) In EN 60950-1:2006/A12:2011 N Delete the addition of 1.3.Z1 / EN 60950-1:2006 Delete the definition 1.2.3.Z1 / EN 60950-1:2006 /A1:2010 1.5.1 (Added info*) 1.7.2.1 (A1:2010) 1.7.2.1 (A12.2011) Add the following NOTE: Added P NOTE Z1 The use of certain substances in electrical and electronic equipment is restricted within the EU: see Directive 2002/95/EC. New Directive 2011/65/11 * In addition, for a PORTABLE SOUND SYSTEM, the instructions shall include a warning that excessive sound pressure from earphones and headphones can cause hearing loss. In EN 60950-1:2006/A12:2011 Delete NOTE Z1 and the addition for Portable Sound System. Add the following clause and annex to the existing standard and amendments. TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N N Page 46 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Zx Protection against excessive sound pressure from personal music players N Zx.1 General This sub-clause specifies requirements for protection against excessive sound pressure from personal music players that are closely coupled to the ear. It also specifies requirements for earphones and headphones intended for use with personal music players. N A personal music player is a portable equipment for personal use, that: is designed to allow the user to listen to recorded or broadcast sound or video; and primarily uses headphones or earphones that can be worn in or on or around the ears; and allows the user to walk around while in use. NOTE 1 Examples are hand-held or body-worn portable CD players, MP3 audio players, mobile phones with MP3 type features, PDA‟s or similar equipment. A personal music player and earphones or headphones intended to be used with personal music players shall comply with the requirements of this sub-clause. The requirements in this sub-clause are valid for music or video mode only. The requirements do not apply: while the personal music player is connected to an external amplifier; or while the headphones or earphones are not used. NOTE 2 An external amplifier is an amplifier which is not part of the personal music player or the listening device, but which is intended to play the music as a standalone music player. The requirements do not apply to: hearing aid equipment and professional equipment; NOTE 3 Professional equipment is equipment sold through special sales channels. All products sold through normal electronics stores are considered not to be professional equipment. analogue personal music players (personal music players without any kind of digital processing of the sound signal) that are brought to the market before the end of 2015. NOTE 4 This exemption has been allowed because this technology is falling out of use and it is expected that within a few years it will no longer exist. This exemption will not be extended to other technologies. For equipment which is clearly designed or intended for use by young children, the limits of EN 71-1 apply. TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 47 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Zx.2 Equipment requirements No safety provision is required for equipment that complies with the following: equipment provided as a package (personal music player with its listening device), where the acoustic output LAeq,T is ≤ 85 dBA measured while playing the fixed “programme simulation noise” as described in EN 50332-1; and a personal music player provided with an analogue electrical output socket for a listening device, where the electrical output is ≤ 27 mV measured as described in EN 50332-2, while playing the fixed “programme simulation noise” as described in EN 50332-1. Verdict N NOTE 1 Wherever the term acoustic output is used in this clause, the 30 s A-weighted equivalent sound pressure level LAeq,T is meant. See also Zx.5 and Annex Zx. All other equipment shall: N a) protect the user from unintentional acoustic outputs exceeding those mentioned above; and b) have a standard acoustic output level not exceeding those mentioned above, and automatically return to an output level not exceeding those mentioned above when the power is switched off; and c) provide a means to actively inform the user of the increased sound pressure when the equipment is operated with an acoustic output exceeding those mentioned above. Any means used shall be acknowledged by the user before activating a mode of operation which allows for an acoustic output exceeding those mentioned above. The acknowledgement does not need to be repeated more than once every 20 h of cumulative listening time; and N N N NOTE 2 Examples of means include visual or audible signals. Action from the user is always required. NOTE 3 The 20 h listening time is the accumulative listening time, independent how often and how long the personal music player has been switched off. d) have a warning as specified in Zx.3; and N e) not exceed the following: 1) equipment provided as a package (player with Its listening device), the acoustic output shall be ≤ 100 dBA measured while playing the fixed “programme simulation noise” described in EN 50332-1; and 2) a personal music player provided with an analogue electrical output socket for a listening device, the electrical output shall be ≤ 150 mV measured as described in EN 50332-2, while playing the fixed “programme simulation noise” described in EN 50332-1. N TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 48 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark For music where the average sound pressure (long term LAeq,T) measured over the duration of the song is lower than the average produced by the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dBA. In this case T becomes the duration of the song. Verdict N NOTE 4 Classical music typically has an average sound pressure (long term LAeq,T) which is much lower than the average programme simulation noise. Therefore, if the player is capable to analyse the song and compare it with the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dBA. For example, if the player is set with the programme simulation noise to 85 dBA, but the average music level of the song is only 65 dBA, there is no need to give a warning or ask an acknowledgement as long as the average sound level of the song is not above the basic limit of 85 dBA. Zx.3 Warning The warning shall be placed on the equipment, or on the packaging, or in the instruction manual and shall consist of the following: the symbol of Figure 1 with a minimum height of 5 mm; and the following wording, or similar: N “To prevent possible hearing damage, do not listen at high volume levels for long periods.” Figure 1 – Warning label (IEC 60417-6044) Alternatively, the entire warning may be given through the equipment display during use, when the user is asked to acknowledge activation of the higher level. Zx.4 Requirements for listening devices (headphones and earphones) TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N Page 49 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Zx.4.1 Wired listening devices with analogue input With 94 dBA sound pressure output LAeq,T, the input voltage of the fixed “programme simulation noise” described in EN 50332-2 shall be ≥ 75 mV. Verdict N This requirement is applicable in any mode where the headphones can operate (active or passive), including any available setting (for example built-in volume level control). NOTE The values of 94 dBA – 75 mV correspond with 85dBA – 27 mV and 100 dBA – 150 mV. Zx.4.2 Wired listening devices with digital input With any playing device playing the fixed “programme simulation noise” described in EN 50332-1 (and respecting the digital interface standards, where a digital interface standard exists that specifies the equivalent acoustic level), the acoustic output LAeq,T of the listening device shall be ≤ 100 dBA. N This requirement is applicable in any mode where the headphones can operate, including any available setting (for example built-in volume level control, additional sound feature like equalization, etc.). NOTE An example of a wired listening device with digital input is a USB headphone. Zx.4.3 Wireless listening devices In wireless mode: with any playing and transmitting device playing the fixed programme simulation noise described in EN 50332-1; and respecting the wireless transmission standards, where an air interface standard exists that specifies the equivalent acoustic level; and with volume and sound settings in the listening device (for example built-in volume level control, additional sound feature like equalization, etc.) set to the combination of positions that maximize the measured acoustic output for the abovementioned programme simulation noise, the acoustic output LAeq,T of the listening device shall be ≤ 100 dBA. N NOTE An example of a wireless listening device is a Bluetooth headphone. Zx.5 Measurement methods Measurements shall be made in accordance with EN 50332-1 or EN 50332-2 as applicable. Unless stated otherwise, the time interval T shall be 30 s. NOTE Test method for wireless equipment provided without listening device should be defined. TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N Page 50 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark 2.7.1 Replace the subclause as follows: Replaced. Verdict P Basic requirements To protect against excessive current, short-circuits and earth faults in PRIMARY CIRCUITS, protective devices shall be included either as integral parts of the equipment or as parts of the building installation, subject to the following, a), b) and c): a) except as detailed in b) and c), protective devices necessary to comply with the requirements of 5.3 shall be included as parts of the equipment; b) for components in series with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault protection may be provided by protective devices in the building installation; c) it is permitted for PLUGGABLE EQUIPMENT Not such equipment TYPE B or PERMANENTLY CONNECTED EQUIPMENT, to rely on dedicated overcurrent and short-circuit protection in the building installation, provided that the means of protection, e.g. fuses or circuit breakers, is fully specified in the installation instructions. If reliance is placed on protection in the building installation, the installation instructions shall so state, except that for PLUGGABLE EQUIPMENT TYPE A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet. This subclause has been declared „void‟. N 3.2.3 Delete the NOTE in Table 3A, and delete also in this table the conduit sizes in parentheses. N 3.2.5.1 Replace 2.7.2 “60245 IEC 53” by “H05 RR-F”; “60227 IEC 52” by “H03 VV-F or H03 VVH2-F”; “60227 IEC 53” by “H05 VV-F or H05 VVH2-F2”. N N In Table 3B, replace the first four lines by the following: Up to and including 6 | b) Over 6 up to and including 10| (0,75) c) Over 10 up to and including 16| (1,0) a) 0,75 | 1,0 | 1,5 | In the conditions applicable to Table 3B delete the a) words “in some countries” in condition . In NOTE 1, applicable to Table 3B, delete the second sentence. 3.2.5.1 (A2:2013) NOTE Z1 The harmonised code designations corresponding to the IEC cord types are given in Annex ZD TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N Page 51 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark 3.3.4 In Table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with the following: Verdict N Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to 4 | Delete the fifth line: conductor sizes for 13 to 16 A 4.3.13.6 (A1:2010) Replace the existing NOTE by the following: Added N NOTE Z1 Attention is drawn to: 1999/519/EC: Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz, and 2006/25/EC: Directive on the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents (artifical optical radiation). Standards taking into account mentioned Recommendation and Directive which demonstrate compliance with the applicable EU Directive are indicated in the OJEC. Annex H Replace the last paragraph of this annex by: N Replaced N At any point 10 cm from the surface of the OPERATOR ACCESS AREA, the dose rate shall not exceed 1 μSv/h (0,1 mR/h) (see NOTE). Account is taken of the background level. Replace the notes as follows: NOTE These values appear in Directive 96/29/Euratom. Delete NOTE 2. Bibliograph Additional EN standards. y ZA NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR CORRESPONDING EUROPEAN PUBLICATIONS ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) Clause Requirement + Test 1.2.4.1 In Denmark, certain types of Class I appliances (see 3.2.1.1) may be provided with a plug not establishing earthing conditions when inserted into Danish socket-outlets. In Norway and Sweden, for requirements see 1.7.2.1 and 7.3 of this annex. In Finland, Norway and Sweden, resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in 1.5.7.1. In addition when a single resistor is used, the resistor must withstand the resistor test in 1.5.7.2. 1.2.13.14 (A11:2009) 1.5.7.1 (A11:2009) TRF No. IEC60950_1B_M2 Result - Remark STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Verdict N N N Page 52 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) Clause Requirement + Test 1.5.8 In Norway, due to the IT power system used (see annex V, Figure V.7), capacitors are required to be rated for the applicable line-to-line voltage (230 V). In Finland, Norway and Sweden, the third dashed sentence is applicable only to equipment as defined in 6.1.2.2 of this annex. N In Finland, Norway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. N 1.5.9.4 1.7.2.1 Result - Remark Verdict N The marking text in the applicable countries shall be as follows: In Finland: "Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan" In Norway: “Apparatet må tilkoples jordet stikkontakt” In Sweden: “Apparaten skall anslutas till jordat uttag” NOTE In Norway, due to regulation for installations of cable distribution systems, and in Sweden, a galvanic isolator shall provide electrical insulation below 5 MHz. The insulation shall withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min. 1.7.2.1 (A11:2009) Translation to Norwegian (the Swedish text will also be accepted in Norway): “Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller via annet jordtilkoplet utstyr – og er tilkoplet et kabel-TV nett, kan forårsake brannfare. For å unngå dette skal det ved tilkopling av utstyret til kabel-TV nettet installeres en galvanisk isolator mellom utstyret og kabel- TV nettet.” Translation to Swedish: ”Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via annan utrustning och samtidigt är kopplad till kabel-TV nät kan i vissa fall medfőra risk főr brand. Főr att undvika detta skall vid anslutning av utrustningen till kabel-TV nät galvanisk isolator finnas mellan utrustningen och kabel-TV nätet.” TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N Page 53 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) Clause Requirement + Test 1.7.2.1 In Denmark, CLASS I PLUGGABLE EQUIPMENT TYPE A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text in Denmark shall be as follows: In Denmark: “Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til stikproppens jord.” N In Denmark, socket-outlets for providing power to other equipment shall be in accordance with the Heavy Current Regulations, Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For STATIONARY EQUIPMENT the socket-outlet shall be in accordance with Standard Sheet DK 1-1b or DK 15a. For CLASS II EQUIPMENT the socket outlet shall be in accordance with Standard Sheet DKA 1-4a. In Denmark, socket-outlets for providing power to other equipment shall be in accordance with the DS 60884-2-D1:2011. For class I equipment the following Standard Sheets are applicable: DK 1-3a, DK 1-1c, DK 1-1d, DK 1-5a or DK 1-7a, with the exception for STATIONARY EQUIPMENT where the socketoutlets shall be in accordance with Standard Sheet DK 1-1b, DK 1-1c, DK 1-1d or DK 1-5a. Socket outlets intended for providing power to Class II apparatus with a rated current of 2,5 A shall be in accordance with DS 60884-2-D1 standard sheet DKA 1-4a. Other current rating socket outlets shall be in compliance with by DS 60884-2-D1 Standard Sheet DKA 1-3a or DKA 1-3b. Justification the Heavy Current Regulations, 6c In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex. In Finland, Norway and Sweden there are additional requirements for the insulation. See 6.1.2.1 and 6.1.2.2 of this annex. In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex. In the United Kingdom, the current rating of the circuit shall be taken as 13 A, not 16 A. N (A2:2013) 1.7.5 1.7.5 (A11:2009) 1.7.5 (A2:2013) 2.2.4 2.3.2 2.3.4 2.6.3.3 TRF No. IEC60950_1B_M2 Result - Remark STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Verdict N N N N N Page 54 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) Clause Requirement + Test 2.7.1 In the United Kingdom, to protect against excessive currents and short-circuits in the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3 shall be conducted, using an external protective device rated 30 A or 32 A. If these tests fail, suitable protective devices shall be included as integral parts of the DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met. In Finland, Norway and Sweden, there are additional requirements for the insulation, see 6.1.2.1 and 6.1.2.2 of this annex. N In Switzerland, supply cords of equipment having a RATED CURRENT not exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC 60884-1 and one of the following dimension sheets: N 2.10.5.13 3.2.1.1 Result - Remark SEV 6532-2.1991 Plug Type 15 250/400 V, 10 A 3P+N+PE SEV 6533-2.1991 Plug Type 11 250 V, 10 A SEV 6534-2.1991 Plug Type 12 250 V, 10 A L+N L+N+PE In general, EN 60309 applies for plugs for currents exceeding 10 A. However, a 16 A plug and socketoutlet system is being introduced in Switzerland, the plugs of which are according to the following dimension sheets, published in February 1998: SEV 5932-2.1998: Plug Type 25 , 3L+N+PE 230/400 V, 16 A SEV 5933-2.1998:Plug Type 21, L+N, 250 V, 16A SEV 5934-2.1998: Plug Type 23, L+N+PE 250 V, 16 A TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Verdict N Page 55 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 3.2.1.1 In Denmark, supply cords of single-phase equipment having a rated current not exceeding13 A shall be provided with a plug according to the Heavy Current Regulations, Section 107-2-D1. Result - Remark Verdict N CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a. If poly-phase equipment and single-phase equipment having a RATED CURRENT exceeding 13 A is provided with a supply cord with a plug, this plug shall be in accordance with the Heavy Current Regulations, Section 107-2-D1 or EN 60309-2. 3.2.1.1 (A2:2013) 3.2.1.1 In Denmark, supply cords of single-phase equipment having a rated current not exceeding 13 A shall be provided with a plug according to DS 608842-D1. CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a. If a single-phase equipment having a RATED CURRENT exceeding 13 A or if a poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with the standard sheets DK 6-1a in DS 60884-2-D1 or EN 60309-2. Justification the Heavy Current Regulations, 6c In Spain, supply cords of single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to UNE 20315:1994. N The plug cord set was approved Supply cords of single-phase equipment having a rated current not exceeding 2,5 A shall be provided with a plug according to UNE-EN 50075:1993. CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules, shall be provided with a plug in accordance with standard UNE 20315:1994. If poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with UNE-EN 60309-2. TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org P Page 56 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark 3.2.1.1 In the United Kingdom, apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug, shall be fitted with a „standard plug‟ in accordance with Statutory Instrument 1768:1994 - The Plugs and Sockets etc. (Safety) Regulations 1994, unless exempted by those regulations. Verdict N NOTE „Standard plug‟ is defined in SI 1768:1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug. 3.2.1.1 In Ireland, apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to I.S. 411 by means of that flexible cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory Instrument 525:1997 - National Standards Authority of Ireland (section 28) (13 A Plugs and Conversion Adaptors for Domestic Use) Regulations 1997. N 3.2.4 In Switzerland, for requirements see 3.2.1.1 of this annex. N 3.2.5.1 In the United Kingdom, a power supply cord with conductor of 1,25 mm2 is allowed for equipment with a rated current over 10 A and up to and including 13 A. N 3.3.4 In the United Kingdom, the range of conductor sizes of flexible cords to be accepted by terminals for equipment with a RATED CURRENT of over 10 A up to and including 13 A is: N 2 2 • 1,25 mm to 1,5 mm nominal cross-sectional area. 4.3.6 In the United Kingdom, the torque test is performed using a socket outlet complying with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment 2:2003 and the plug part of DIRECT PLUG-IN EQUIPMENT shall be assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16 and 12.17, except that the test of 12.17 is performed at not less than 125 °C. Where the metal earth pin is replaced by an Insulated Shutter Opening Device (ISOD), the requirements of clauses 22.2 and 23 also apply. P 4.3.6 In Ireland, DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such devices shall comply with Statutory Instrument 526:1997 - National Standards Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets for domestic use) Regulations, 1997. N TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Page 57 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test 5.1.7.1 In Finland, Norway and Sweden TOUCH CURRENT measurement results exceeding 3,5 mA r.m.s. are permitted only for the following equipment: Result - Remark Verdict N • STATIONARY PLUGGABLE EQUIPMENT TYPE A that is intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied, for example, in a telecommunication centre; and has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR; and is provided with instructions for the installation of that conductor by a SERVICE PERSON; • STATIONARY PLUGGABLE EQUIPMENT TYPE B; • STATIONARY PERMANENTLY CONNECTED EQUIPMENT. 6.1.2.1 (A1:2010) In Finland, Norway and Sweden, add the following text between the first and second paragraph of the compliance clause: If this insulation is solid, including insulation forming part of a component, it shall at least consist of either two layers of thin sheet material, each of which shall pass the electric strength test below, or one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. Alternatively for components, there is no distance through insulation requirements for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition passes the tests and inspection criteria of 2.10.11 with an electric strength test of 1,5 kV multiplied by 1,6 (the electric strength test of 2.10.10 shall be performed using 1,5 kV), and is subject to ROUTINE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kV. TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N Page 58 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark It is permitted to bridge this insulation with an optocoupler complying with 2.10.5.4 b). Verdict N It is permitted to bridge this insulation with a capacitor complying with EN 60384-14:2005, subclass Y2. A capacitor classified Y3 according to EN 60384-14:2005, may bridge this insulation under the following conditions: the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN 60384-14, which in addition to the Y3 testing, is tested with an impulse test of 2,5 kV defined in EN 60950-1:2006, 6.2.2.1; the additional testing shall be performed on all the test specimens as described in EN 60384-14: the impulse test of 2,5 kV is to be performed before the endurance test in EN 60384-14, in the sequence of tests as described in EN 60384-14. 6.1.2.2 In Finland, Norway and Sweden, the exclusions are applicable for PERMANENTLY CONNECTED EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B and equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON. N 7.2 In Finland, Norway and Sweden, for requirements see 6.1.2.1 and 6.1.2.2 of this annex. N The term TELECOMMUNICATION NETWORK in 6.1.2 being replaced by the term CABLE DISTRIBUTION SYSTEM. 7.3 (A11:2009) In Norway and Sweden, for requirements see 1.2.13.14 and 1.7.2.1 of this annex. TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org N Page 59 of 59 Report No.: DE115902 IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Annex ZD (informative) IEC and CENELEC code designations for flexible cords Type of flexible cord Code designations IEC CENELEC PVC insulated cords Flat twin tinsel cord 60227 IEC 41 H03VH-Y Light polyvinyl chloride sheathed flexible cord 60227 IEC 52 H03VV-F H03VVH2-F Ordinary polyvinyl chloride sheathed flexible cord 60277 IEC 53 H05VV-F H05VVH2-F Rubber insulated cords Braided cord 60245 IEC 51 H03RT-F Ordinary tough rubber sheathed flexible cord 60245 IEC 53 H05RR-F Ordinary polychloroprene sheathed flexible cord 60245 IEC 57 H05RN-F Heavy polychloroprene sheathed flexible cord 60245 IEC 66 H07RN-F Cords having high flexibility Rubber insulated and sheathed cord 60245 IEC 86 H03RR-H Rubber insulated, crosslinked PVC sheathed cord 60245 IEC 87 H03RV4-H Crosslinked PVC insulated and sheathed cord 60245 IEC 88 H03V4V4-H End of Test Report TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Appendix Page 1 of 5 Report No.: DE115902 Product Photographs STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Appendix Page 2 of 5 Report No.: DE115902 Product Photographs STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Appendix Page 3 of 5 Report No.: DE115902 Product Photographs STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Appendix Page 4 of 5 Report No.: DE115902 Product Photographs STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org Appendix Page 5 of 5 Report No.: DE115902 Product Photographs STC (Dongguan) Company Limited 68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770) Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract Tagged PDF : Yes XMP Toolkit : 3.1-702 Create Date : 2016:04:13 08:14:10Z Creator Tool : Microsoft® Office Word 2007 Modify Date : 2016:04:13 17:08:20+08:00 Metadata Date : 2016:04:13 17:08:20+08:00 Format : application/pdf Description : IECEE Creator : JMW Title : IEC TEST REPORT FORM TEMPLATE Keywords : TRF - CB Scheme Producer : Microsoft® Office Word 2007 Document ID : uuid:90721130-ad0a-4d99-a151-02ab1ba37693 Instance ID : uuid:ea716dd2-4a24-46cd-a697-2f3ef5ee295c Page Count : 65 Language : zh-CN Subject : IECEE Author : JMWEXIF Metadata provided by EXIF.tools