IEC REPORT FORM 560641(Full River) LVD Certificate And

2016-04-26

: Pdf 560641(Full River) Lvd Certificate And Report 560641(Full_River)_LVD_Certificate_and__Report CertsReports 560641 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 65

STC (Dongguan) Company Limited
EC DECLARATION OF CONFORMITY
Reference Number:
LVD-D161916DOC
Intracom Asia Co., Ltd
4F., No.77, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221, Taiwan
declare the product
Description:
8-Port PoE+ Desktop Gigabit Switch
Brand Name:
Intellinet
Model:
560641
complies with the requirements of the
EC Low Voltage Directive 2006/95/EC (until April 19th, 2016) and
EC Low Voltage Directive 2014/35/EU (from April 20th, 2016)
Applicable Standard(s) with amendments:
EN 60950-1:2006+A11:2009+A1:2010+A12: 2011+A2:2013
General Remarks:
This declaration is only valid when used in conjunction with the technical file(s) refers to DE115902
This declaration applies specifically to the sample(s) investigated in the technical report mentioned above and not to the bulk.
The CE mark as shown below can be used, under the responsibility of the manufacturer, after completion of an EC
Declaration of Conformity and compliance with all relevant EC Directives.
Manufacturer/Importer
Test Laboratory
Signature
LI Chang Jun, Ricky
Authorized Signatory
Electrical Safety Department
For and on behalf of
STC (Dongguan) Company Limited
Date of Issue:
2016-04-13
www.dgstc.org
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
TEST REPORT
IEC/EN 60950-1
Information technology equipment Safety
Part 1: General requirements
Report Number. .............................. :
DE115902
Date of issue ................................... :
2016-04-13
Total number of pages ...................
Page 1 to 59 for test report
Appendix 1 to 5 for product photographs
Testing Laboratory ........................ :
STC (Dongguan) Company Limited
Address ........................................... :
68 Fumin Nan Road, Dalang , Dongguan City,
Guangdong Province, P.R. China
Applicant’s name ........................... :
Intracom Asia Co., Ltd
Address ........................................... :
4F., No.77, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221,
Taiwan
Test specification:
Standard ......................................... :
IEC 60950-1:2005 (2nd Edition); Am 1:2009; Am 2: 2013
EN 60950-1:2006+A11:2009+A1:2010+A12: 2011+A2:2013
Test procedure ............................... :
N/A
Non-standard test method………..:
N/A
Test Report Form No. .................... :
IEC60950_1B_M2
Test Report Form(s) Originator .... :
SGS Fimko Ltd
Master TRF ..................................... :
Dated 2010-04
Modified by ..................................... :
STC
Modified Date ................................. :
2013-12
Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is
acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and
context.
Test item description ..................... :
8-Port PoE+ Desktop Gigabit Switch
Trade Mark ...................................... :
Intellinet
Manufacturer .................................. :
Intracom Asia Co., Ltd
Address ........................................... :
4F., No.77, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221,
Taiwan
Model/Type reference .................... :
560641
Ratings ............................................ :
100-240VAC 50/60Hz, Max.2.2A
Page 2 of 59 Report No.: DE115902
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Testing procedure and testing location:
Testing Laboratory:
STC (Dongguan) Company Limited
Testing location/ address ...................... :
68 Fumin Nan Road, Dalang, Dongguan City,
Guangdong Province, P.R. China
Associated Laboratory:
Testing location/ address ...................... :
Tested by (name + signature) ..... :
Amy Lin
Approved by (+ signature) ........... :
Ricky Lee
Testing procedure: TMP
Tested by (name + signature) ..... :
Approved by (+ signature) ............ :
Testing location/ address ...................... :
Testing procedure: WMT
Tested by (name + signature) ..... :
Witnessed by (+ signature) .......... :
Approved by (+ signature) ........... :
Testing location/ address ...................... :
Testing procedure: SMT
Tested by (name + signature) ..... :
Approved by (+ signature) ............ :
Supervised by (+ signature) ........ :
Testing location/ address ................ :
Testing procedure: RMT
Tested by (name + signature) ..... :
Approved by (+ signature) ............ :
Supervised by (+ signature) ........ :
Testing location/ address ...................... :
Page 3 of 59 Report No.: DE115902
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
List of Attachments (including a total number of pages in each attachment):
Page 1 to 59 for test report
Appendix 1 to 5 for product photographs
Summary of testing:
The sample(s) tested complies with the requirements of EN 60950-1:2006+ A11:2009+ A1:2010+ A12:2011
+A2:2013
Tests performed (name of test and test clause):
EN 60950-1:2006+ A11:2009+ A1:2010+A12:2011
+ A2:2013
Testing location:
68 Fumin Nan Road, Dalang, Dongguan City,
Guangdong Province, P.R. China
Summary of compliance with National Differences
List of countries addressed: Europe
The product fulfils the requirements of EN 60950-1:2006+ A11:2009+ A1:2010+A12:2011+A2:2013
Copy of marking plate:
Page 4 of 59 Report No.: DE115902
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Test item particulars .................................................. :
8-Port PoE+ Desktop Gigabit Switch
Equipment mobility ................................................ :
[x] movable [] hand-held [] transportable
[] stationary [] for building-in [] direct plug-in
Connection to the mains ........................................ :
[x] pluggable equipment
[x] type A [] type B
[] permanent connection
[x] detachable power supply cord
[] non-detachable power supply cord
[] not directly connected to the mains
Operating condition ................................................ :
[x] continuous
[] rated operating / resting time:
Access location ...................................................... :
[x] operator accessible
[] restricted access location
Over voltage category (OVC) ................................ :
[] OVC I [x] OVC II [] OVC III [] OVC IV
[] other
Mains supply tolerance (%) or absolute mains
supply values .......................................................... :
+6%, -10%
Tested for IT power systems ................................. :
[] Yes [x] No
IT testing, phase-phase voltage (V) ...................... :
N/A
Class of equipment ................................................ :
[x] Class I [] Class II [] Class III
[] Not classified
Considered current rating of protective device as
part of the building installlation (A) ...................... :
16A
Pollution degree (PD) ............................................. :
[] PD 1 [x] PD 2 [] PD 3
IP protection class .................................................. :
IPX0
Altitude during operation (m) ................................ :
2000
Altitude of test laboratory (m) ............................... :
< 2000
Mass of equipment (kg) ......................................... :
1.8kg
Possible test case verdicts:
- test case does not apply to the test object ............ :
N (N/A)
- test object does meet the requirement .................. :
P (Pass)
- test object does not meet the requirement ............ :
F (Fail)
Testing .......................................................................... :
Date of receipt of test item ......................................... :
2014-08-20; 2014-12-08
Date(s) of performance of tests ................................. :
2014-08-20 to 2014-10-16;
2014-12-08 to 2014-12-23
Page 5 of 59 Report No.: DE115902
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, without the written approval of the Issuing testing laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
This report shall not be reproduced unless prior written approval from STC (Dongguan) Company Limited
For Conditions of issuance of this test report, please refer to the below Homepage.
Page 1 to 59 for test report
Appendix 1 to 5 for product photographs
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
When differences exist; they shall be identified in the General product information section.
General product information:
The submitted unit is Class I 8-Port PoE+ Desktop Gigabit Switch, Which including POE function and net
function. Power output up to 34watts on ports 1-4 (IEEE 802.3at); and power output up to 15.4watts on
ports 5-8 (IEEE 802.3af). It supplied by mains via a detachable power supply cord.
The max operated temperature is 40C which is specified by manufacturer.
Abbreviations used in the report:
- normal conditions N.C. - single fault conditions S.F.C
- functional insulation OP - basic insulation BI
- double insulation DI - supplementary insulation SI
- between parts of opposite
polarity BOP - reinforced insulation RI
Indicate used abbreviations (if any)
Page 6 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
1
GENERAL
P
1.5
Components
P
1.5.1
General
P
Comply with IEC 60950-1 or relevant component
standard
see appended table
P
1.5.2
Evaluation and testing of components
P
1.5.3
Thermal controls
Not used
N
1.5.4
Transformers
See Annex C
P
1.5.5
Interconnecting cables
No hazards
P
1.5.6
Capacitors bridging insulation
Approved capacitor used
P
1.5.7
Resistors bridging insulation
No such resistors
N
1.5.7.1
Resistors bridging functional, basic or supplementary
insulation
N
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
N
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
N
1.5.8
Components in equipment for IT power systems
Not for IT power distribution
systems
N
1.5.9
Surge suppressors
Varistor V1 was approved
P
1.5.9.1
General
See Annex Q
P
1.5.9.2
Protection of VDRs
Fuse F1 used
P
1.5.9.3
Bridging of functional insulation by a VDR
P
1.5.9.4
Bridging of basic insulation by a VDR
N
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
No such Varistor
N
1.6
Power interface
P
1.6.1
AC power distribution systems
TN
P
1.6.2
Input current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
Not hand-held equipment
N
1.6.4
Neutral conductor
N
1.7
Marking and instructions
P
1.7.1
Power rating and identification markings
See below
P
1.7.1.1
Power rating marking
P
Multiple mains supply connections..........................:
N
Rated voltage(s) or voltage range(s) (V) ............... :
100-240V
P
Symbol for nature of supply, for d.c. only ............... :
AC input
N
Page 7 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Rated frequency or rated frequency range (Hz) .... :
50/60Hz
P
Rated current (mA or A) ........................................ :
Max. 2.2A
P
1.7.1.2
Identification markings
See copy of marking plate
P
Manufacturer‟s name or trade-mark or identification
mark ....................................................................... :
Intellinet
P
Model identification or type reference ..................... :
560641
P
Symbol for Class II equipment only ........................ :
Class I
N
Other markings and symbols ................................. :
Additional symbol or marking
does not give rise to
misunderstanding.
P
1.7.1.3
Use of graphical symbols
P
1.7.2
Safety instructions and marking
P
1.7.2.1
General
P
1.7.2.2
Disconnect devices
Appliance coupler as
disconnect divices
P
1.7.2.3
Overcurrent protective device
N
1.7.2.4
IT power distribution systems
N
1.7.2.5
Operator access with a tool
N
1.7.2.6
Ozone
No ozone radiation
N
1.7.3
Short duty cycles
Continuous operation
N
1.7.4
Supply voltage adjustment .................................... :
N
Methods and means of adjustment; reference to
installation instructions .......................................... :
N
1.7.5
Power outlets on the equipment ........................... :
No such power outlets
N
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :
F1: T5A 250VAC
P
1.7.7
Wiring terminals
P
1.7.7.1
Protective earthing and bonding terminals ........... :
on inlet
P
1.7.7.2
Terminals for a.c. mains supply conductors
No such terminal provided
N
1.7.7.3
Terminals for d.c. mains supply conductors
No d.c. mains
N
1.7.8
Controls and indicators
P
1.7.8.1
Identification, location and marking ...................... :
N
1.7.8.2
Colours ................................................................ :
No colour impairs safety
N
1.7.8.3
Symbols according to IEC 60417 ......................... :
P
1.7.8.4
Markings using figures ........................................ :
P
1.7.9
Isolation of multiple power sources ..................... :
N
1.7.10
Thermostats and other regulating devices .......... :
No such adjustable devices
N
1.7.11
Durability
Legible after test
P
1.7.12
Removable parts
No such parts
N
Page 8 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
1.7.13
Replaceable batteries .......................................... :
No such battery
N
Language(s) ......................................................... :
1.7.14
Equipment for restricted access locations ............ :
Not for installation in
restricted access locations
N
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
P
2.1.1.1
Access to energized parts
Cannot touch live part and
basic insulation
P
Test by inspection .................................................. :
No hazards
P
Test with test finger (Figure 2A) ............................ :
No hazards
P
Test with test pin (Figure 2B) ................................. :
No hazards
P
Test with test probe (Figure 2C) ............................ :
No hazards
P
2.1.1.2
Battery compartments
No compartments
N
2.1.1.3
Access to ELV wiring
No ELV circuit
N
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
2.1.1.4
Access to hazardous voltage circuit wiring
N
2.1.1.5
Energy hazards ...................................................... :
(see appended tables 2.1.1.5)
P
2.1.1.6
Manual controls
No manual control
N
2.1.1.7
Discharge of capacitors in equipment
CX1: 0.47μF; CX2: 0.47μF
P
Measured voltage (V); time-constant (s) ................ :
7V after 1s
2.1.1.8
Energy hazards d.c. mains supply
N
a) Capacitor connected to the d.c. mains supply ... :
N
b) Internal battery connected to the d.c. mains
supply ..................................................................... :
N
2.1.1.9
Audio amplifiers ..................................................... :
No such componet
N
2.1.2
Protection in service access areas
N
2.1.3
Protection in restricted access locations
N
2.2
SELV circuits
P
2.2.1
General requirements
P
2.2.2
Voltages under normal conditions (V) ...................:
(see appended tables 2.2)
P
2.2.3
Voltages under fault conditions (V) ........................:
(see appended tables 2.2)
P
2.2.4
Connection of SELV circuits to other circuits ....... :
Connect to SELV circuit only
P
2.3
TNV circuits
P
Page 9 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
2.3.1
Limits
P
Type of TNV circuits ...............................................:
TNV-1
2.3.2
Separation from other circuits and from accessible
parts
P
2.3.2.1
General requirements
P
2.3.2.2
Protection by basic insulation
P
2.3.2.3
Protection by earthing
P
2.3.2.4
Protection by other constructions ..........................:
N
2.3.3
Separation from hazardous voltages
P
Insulation employed ................................................:
Main protective earthing
terminal used
2.3.4
Connection of TNV circuits to other circuits
N
Insulation employed ................................................:
2.3.5
Test for operating voltages generated externally
N
2.4
Limited current circuits
P
2.4.1
General requirements
Considered.
P
2.4.2
Limit values
173.6mA
P
Frequency (Hz) ....................................................... :
248KHz
Measured current (mA) ........................................... :
3.47mA
Measured voltage (V) ............................................. :
6.94V
Measured circuit capacitance (nF or µF) ................ :
CY3: 3300PF
2.4.3
Connection of limited current circuits to other
circuits
Under normal operating
condition and in the event of a
single failure
P
2.5
Limited power sources
N
a) Inherently limited output
N
b) Impedance limited output
N
c) Regulating network limited output under normal
operating and single fault condition
(see appended table 2.5)
N
d) Overcurrent protective device limited output
N
Max. output voltage (V), max. output current (A),
max. apparent power (VA) ......................................:
Current rating of overcurrent protective device (A) .:
Use of integrated circuit (IC) current limiters
2.6
Provisions for earthing and bonding
P
2.6.1
Protective earthing
P
Page 10 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
2.6.2
Functional earthing
N
2.6.3
Protective earthing and protective bonding
conductors
P
2.6.3.1
General
P
2.6.3.2
Size of protective earthing conductors
Power cord set
P
Rated current (A), cross-sectional area (mm2),
AWG .......................................................................:
2.2A, 0.75mm2
2.6.3.3
Size of protective bonding conductors
P
Rated current (A), cross-sectional area (mm2),
AWG .......................................................................:
Protective current rating (A), cross-sectional area
(mm2), AWG ...........................................................:
2.2A, 18AWG
2.6.3.4
Resistance of earthing conductors and their
terminations; resistance (), voltage drop (V), test
current (A), duration (min) ......................................:
0.022Ω
P
2.6.3.5
Colour of insulation .................................................:
The color combination green
and yellow is used
P
2.6.4
Terminals
P
2.6.4.1
General
P
2.6.4.2
Protective earthing and bonding terminals
Appliance coupler used
P
Rated current (A), type, nominal thread diameter
(mm) .......................................................................:
2.6.4.3
Separation of the protective earthing conductor from
protective bonding conductors
P
2.6.5
Integrity of protective earthing
P
2.6.5.1
Interconnection of equipment
N
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
P
2.6.5.3
Disconnection of protective earth
N
2.6.5.4
Parts that can be removed by an operator
Applianc coupler
P
2.6.5.5
Parts removed during servicing
N
2.6.5.6
Corrosion resistance
N
2.6.5.7
Screws for protective bonding
P
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N
2.7
Overcurrent and earth fault protection in primary circuits
P
2.7.1
Basic requirements
Fuse F1 used
P
Instructions when protection relies on building
installation
N
2.7.2
Faults not simulated in 5.3.7
N
Page 11 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
2.7.3
Short-circuit backup protection
By building installation
P
2.7.4
Number and location of protective devices ........... :
One fuse
P
2.7.5
Protection by several devices
N
2.7.6
Warning to service personnel ................................ :
N
2.8
Safety interlocks
N
2.8.1
General principles
No safety interlocks
N
2.8.2
Protection requirements
N
2.8.3
Inadvertent reactivation
N
2.8.4
Fail-safe operation
N
Protection against extreme hazard
N
2.8.5
Moving parts
N
2.8.6
Overriding
N
2.8.7
Switches, relays and their related circuits
N
2.8.7.1
Separation distances for contact gaps and their
related circuits (mm) .............................................. :
N
2.8.7.2
Overload test
N
2.8.7.3
Endurance test
N
2.8.7.4
Electric strength test
(see appended table 5.2)
N
2.8.8
Mechanical actuators
N
2.9
Electrical insulation
P
2.9.1
Properties of insulating materials
P
2.9.2
Humidity conditioning
48 hrs
P
Relative humidity (%), temperature (°C) ............... :
30°C, 93%
2.9.3
Grade of insulation
Basic insulation
P
2.9.4
Separation from hazardous voltages
P
Method(s) used ..................................................... :
Method 1
2.10
Clearances, creepage distances and distances through insulation
P
2.10.1
General
P
2.10.1.1
Frequency .............................................................. :
<30KHz
P
2.10.1.2
Pollution degrees ................................................... :
2
P
2.10.1.3
Reduced values for functional insualtion
P
2.10.1.4
Intervening unconnected conductive parts
P
2.10.1.5
Insulation with varying dimensions
N
2.10.1.6
Special separation requirements
N
Page 12 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
2.10.1.7
Insulation in circuits generating starting pulses
N
2.10.2
Determination of working voltage
P
2.10.2.1
General
See appended table 2.10.2
P
2.10.2.2
RMS working voltage
P
2.10.2.3
Peak working voltage
P
2.10.3
Clearances
N
2.10.3.1
General
P
2.10.3.2
Mains transient voltages
2500V
P
a) AC mains supply ................................................ :
100-240V
P
b) Earthed d.c. mains supplies .............................. :
N
c) Unearthed d.c. mains supplies .......................... :
N
d) Battery operation ............................................... :
N
2.10.3.3
Clearances in primary circuits
See appended table 2.10.3 &
2.10.4
P
2.10.3.4
Clearances in secondary circuits
N
2.10.3.5
Clearances in circuits having starting pulses
N
2.10.3.6
Transients from a.c. mains supply ......................... :
N
2.10.3.7
Transients from d.c. mains supply ......................... :
N
2.10.3.8
Transients from telecommunication networks and
cable distribution systems ...................................... :
N
2.10.3.9
Measurement of transient voltage levels
N
a) Transients from a mains suplply
N
For an a.c. mains supply ........................................ :
N
For a d.c. mains supply .......................................... :
N
b) Transients from a telecommunication network :
N
2.10.4
Creepage distances
See appended table 2.10.3 &
2.10.4
P
2.10.4.1
General
P
2.10.4.2
Material group and caomparative tracking index
P
CTI tests ................................................................. :
IIIb
2.10.4.3
Minimum creepage distances
P
2.10.5
Solid insulation
See appended table 2.10.5
P
2.10.5.1
General
P
2.10.5.2
Distances through insulation
P
2.10.5.3
Insulating compound as solid insulation
N
2.10.5.4
Semiconductor devices
N
2.10.5.5.
Cemented joints
N
2.10.5.6
Thin sheet material General
N
Page 13 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
2.10.5.7
Separable thin sheet material
N
Number of layers (pcs) ........................................... :
2.10.5.8
Non-separable thin sheet material
N
2.10.5.9
Thin sheet material standard test procedure
N
Electric strength test
2.10.5.10
Thin sheet material alternative test procedure
N
Electric strength test
2.10.5.11
Insulation in wound components
P
2.10.5.12
Wire in wound components
P
Working voltage ..................................................... :
N
a) Basic insulation not under stress ....................... :
N
b) Basic, supplemetary, reinforced insulation ........ :
N
c) Compliance with Annex U .................................. :
N
Two wires in contact inside wound component;
angle between 45 and 90 .................................... :
Separated by tape and tube
P
2.10.5.13
Wire with solvent-based enamel in wound
components
N
Electric strength test
Routine test
N
2.10.5.14
Additional insulation in wound components
N
Working voltage ..................................................... :
N
- Basic insulation not under stress ......................... :
N
- Supplemetary, reinforced insulation .................... :
N
2.10.6
Construction of printed boards
P
2.10.6.1
Uncoated printed boards
See appended table 2.10.3 &
2.10.4
P
2.10.6.2
Coated printed boards
N
2.10.6.3
Insulation between conductors on the same inner
surface of a printed board
N
2.10.6.4
Insulation between conductors on different layers of
a printed board
N
Distance through insulation
N
Number of insulation layers (pcs) ........................... :
N
2.10.7
Component external terminations
N
2.10.8
Tests on coated printed boards and coated
components
N
2.10.8.1
Sample preparation and preliminary inspection
N
2.10.8.2
Thermal conditioning
N
2.10.8.3
Electric strength test
N
Page 14 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
2.10.8.4
Abrasion resistance test
N
2.10.9
Thermal cycling
N
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
N
2.10.11
Tests for semiconductor devices and cemented
joints
N
2.10.12
Enclosed and sealed parts
N
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1
General
P
3.1.1
Current rating and overcurrent protection
No hazards
P
3.1.2
Protection against mechanical damage
No hazards
P
3.1.3
Securing of internal wiring
No hazards
P
3.1.4
Insulation of conductors
Basic insulation for inside
P
3.1.5
Beads and ceramic insulators
No such parts
N
3.1.6
Screws for electrical contact pressure
No such screw
N
3.1.7
Insulating materials in electrical connections
N
3.1.8
Self-tapping and spaced thread screws
No such screw
N
3.1.9
Termination of conductors
Screw and soldering
P
10 N pull test
P
3.1.10
Sleeving on wiring
Heat-shrinkable tube fixed on
terminal
P
3.2
Connection to a mains supply
P
3.2.1
Means of connection............................................:
Mains plug and appliance
coupler
P
3.2.1.1
Connection to an a.c. mains supply
P
3.2.1.2
Connection to a d.c. mains supply
N
3.2.2
Multiple supply connections
N
3.2.3
Permanently connected equipment
Not such equipment
N
Number of conductors, diameter of cable and
conduits (mm) ....................................................... :
3.2.4
Appliance inlets
Appliance inlet was approved
P
3.2.5
Power supply cords
Power cord set was approved
P
3.2.5.1
AC power supply cords
P
Type ...................................................................... :
H03VV-F
Rated current (A), cross-sectional area (mm2),
AWG ..................................................................... :
3G0.75mm2
3.2.5.2
DC power supply cords
N
3.2.6
Cord anchorages and strain relief
Detached power cord used
N
Page 15 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Mass of equipment (kg), pull (N) ......................... :
Longitudinal displacement (mm) ........................... :
3.2.7
Protection against mechanical damage
N
3.2.8
Cord guards
N
Diameter or minor dimension D (mm); test mass (g)
............................................................................... :
Radius of curvature of cord (mm) .......................... :
3.2.9
Supply wiring space
N
3.3
Wiring terminals for connection of external conductors
N
3.3.1
Wiring terminals
Appliance coupler used
N
3.3.2
Connection of non-detachable power supply cords
N
3.3.3
Screw terminals
N
3.3.4
Conductor sizes to be connected
N
Rated current (A), cord/cable type, cross-sectional
area (mm2) ............................................................. :
3.3.5
Wiring terminal sizes
N
Rated current (A), type, nominal thread diameter
(mm) ..................................................................... :
3.3.6
Wiring terminal design
N
3.3.7
Grouping of wiring terminals
N
3.3.8
Stranded wire
N
3.4
Disconnection from the mains supply
P
3.4.1
General requirement
P
3.4.2
Disconnect devices
Appliance coupler
P
3.4.3
Permanently connected equipment
N
3.4.4
Parts which remain energized
N
3.4.5
Switches in flexible cords
N
3.4.6
Number of poles - single-phase and d.c. equipment
P
3.4.7
Number of poles - three-phase equipment
N
3.4.8
Switches as disconnect devices
N
3.4.9
Plugs as disconnect devices
Appliance coupler used also
N
3.4.10
Interconnected equipment
N
3.4.11
Multiple power sources
N
3.5
Interconnection of equipment
P
3.5.1
General requirements
P
3.5.2
Types of interconnection circuits .......................... :
SELV circuits to SELV circuits
P
Page 16 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
3.5.3
ELV circuits as interconnection circuits
N
3.5.4
Data ports for additional equipment
P
4
PHYSICAL REQUIREMENTS
P
4.1
Stability
N
Angle of 10
N
Test force (N) ......................................................... :
< 7kg
N
4.2
Mechanical strength
P
4.2.1
General
Metal enclosure used
P
Rack-mounted equipment.
P
4.2.2
Steady force test, 10 N
N
4.2.3
Steady force test, 30 N
N
4.2.4
Steady force test, 250 N
P
4.2.5
Impact test
P
Fall test
500g, 1.3m
P
Swing test
500g, 1.3m
P
4.2.6
Drop test; height (mm) ........................................... :
N
4.2.7
Stress relief test
Metal enclosure used
N
4.2.8
Cathode ray tubes
No CRT.
N
Picture tube separately certified ............................ :
N
4.2.9
High pressure lamps
No high pressure lamps.
N
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
Not such equipments
N
4.3
Design and construction
P
4.3.1
Edges and corners
Edges and corners are
rounded or smoothed.
P
4.3.2
Handles and manual controls; force (N) ............. :
No handles or controls
provided
N
4.3.3
Adjustable controls
No adjustable controls.
N
4.3.4
Securing of parts
P
4.3.5
Connection by plugs and sockets
P
4.3.6
Direct plug-in equipment
N
Torque .................................................................. :
Compliance with the relevant mains plug standard
............................................................................... :
N
4.3.7
Heating elements in earthed equipment
No heating elements.
N
4.3.8
Batteries
No battery used
N
- Overcharging of a rechargeable battery
N
Page 17 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
- Unintentional charging of a non-rechargeable
battery
N
- Reverse charging of a rechargeable battery
N
- Excessive discharging rate for any battery
N
4.3.9
Oil and grease
No oil or grease.
N
4.3.10
Dust, powders, liquids and gases
Equipment in intended use
not considered to be exposed
to these.
N
4.3.11
Containers for liquids or gases
No container for liquid or gas.
N
4.3.12
Flammable liquids ................................................. :
No flammable liquid.
N
Quantity of liquid (l) ............................................... :
N
Flash point (C) ..................................................... :
N
4.3.13
Radiation
P
4.3.13.1
General
N
4.3.13.2
Ionizing radiation
N
Measured radiation (pA/kg) .................................. :
Measured high-voltage (kV) .................................. :
Measured focus voltage (kV) ................................ :
CRT markings ....................................................... :
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
N
Part, property, retention after test, flammability
classification ......................................................... :
N
4.3.13.4
Human exposure to ultraviolet (UV) radiation ....... :
N
4.3.13.5
Lasers (including laser diodes) and LEDs
P
4.3.13.5.1
Lasers (including laser laser diodes)
N
Laser class ............................................................ :
4.3.13.5.2
Light emitting diodes (LEDs)
LED used for indication only
P
4.3.13.6
Other types ........................................................... :
N
4.4
Protection against hazardous moving parts
N
4.4.1
General
No moving parts
N
4.4.2
Protection in operator access areas .................... :
N
Household and home/office document/media
shredders
(see Annex EE)
N
4.4.3
Protection in restricted access locations ............. :
N
4.4.4
Protection in service access areas
N
4.4.5
Protection against moving fan blades
N
4.4.5.1
General
N
Not considered to cause pain or injury. a)………….:
N
Page 18 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Is considered to cause pain, not injury. b) …………:
N
Considered to cause injury. c) …………:
N
4.4.5.2
Protection for users
N
Use of symbol or warning ……………………………:
N
4.4.5.3
Protection for service persons
N
Use of symbol or warning ……………………………:
N
4.5
Thermal requirements
P
4.5.1
General
P
4.5.2
Temperature tests
P
Normal load condition per Annex L ...................... :
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5
Resistance to abnormal heat ............................... :
(see appended table 4.5.5)
P
4.6
Openings in enclosures
P
4.6.1
Top and side openings
side openings
P
Dimensions (mm) ................................................ :
Diameter: 2.30mm
4.6.2
Bottoms of fire enclosures
Metal enclosure
P
Construction of the bottomm, dimensions (mm) . :
4.6.3
Doors or covers in fire enclosures
No doors or covers
N
4.6.4
Openings in transportable equipment
Not such equipment.
N
4.6.4.1
Constructional design measures
N
Dimensions (mm) ................................................ :
4.6.4.2
Evaluation measures for larger openings
N
4.6.4.3
Use of metallized parts
N
4.6.5
Adhesives for constructional purposes
No barrier of screen fixed by
glue inside subwoofer
N
Conditioning temperature (C), time (weeks) ....... :
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
Metal enclosure
P
Method 1, selection and application of components
wiring and materials
See cl 4.7.2.2
P
Method 2, application of all of simulated fault
condition tests
N
4.7.2
Conditions for a fire enclosure
N
4.7.2.1
Parts requiring a fire enclosure
N
4.7.2.2
Parts not requiring a fire enclosure
P
Page 19 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
4.7.3
Materials
P
4.7.3.1
General
See appended table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
N
4.7.3.3
Materials for components and other parts outside
fire enclosures
Not require fire enclosure
N
4.7.3.4
Materials for components and other parts inside fire
enclosures
N
4.7.3.5
Materials for air filter assemblies
No air filter assemblies
N
4.7.3.6
Materials used in high-voltage components
No high-voltage component
N
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
P
5.1.1
General
Class I equipment
P
5.1.2
Configuration of equipment under test (EUT)
P
5.1.2.1
Single connection to an a.c. mains supply
P
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
N
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
N
5.1.3
Test circuit
Figure 5A
P
5.1.4
Application of measuring instrument
Annex D
P
5.1.5
Test procedure
Between Mains and metal
enclosure & terminal
P
5.1.6
Test measurements
P
Supply voltage (V) ................................................. :
254.4V, 60Hz
Measured touch current (mA) ............................... :
1.38
Max. allowed touch current (mA) .......................... :
3.5
Measured protective conductor current (mA) ....... :
--
Max. allowed protective conductor current (mA) ... :
--
5.1.7
Equipment with touch current exceeding 3.5 mA
N
5.1.7.1
General ................................................................. :
N
5.1.7.2
Simultaneous multiple connections to the supply
N
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
N
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable distribution
system
N
Supply voltage (V) ................................................. :
Measured touch current (mA) ............................... :
Page 20 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Max. allowed touch current (mA) .......................... :
5.1.8.2
Summation of touch currents from
telecommunication networks
N
a) EUT with earthed telecommunication ports ...... :
N
b) EUT whose telecommunication ports have no
reference to protective earth
N
5.2
Electric strength
P
5.2.1
General
(see appended table 5.2)
P
5.2.2
Test procedure
(see appended table 5.2)
P
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal operation
(see appended table 5.3)
P
5.3.2
Motors
N
5.3.3
Transformers
(see appended Annex C)
P
5.3.4
Functional insulation .............................................. :
Result see appened table 5.3
P
5.3.5
Electromechanical components
No such component
N
5.3.6
Audio amplifiers in ITE .......................................... :
No such component
N
5.3.7
Simulation of faults
(see appended table 5.3)
P
5.3.8
Unattended equipment
No such equipment
N
5.3.9
Compliance criteria for abnormal operating and fault
conditions
P
5.3.9.1
During the tests
No fire, no molten metal, no
enclosure deformation and no
temperature exceeding those
in table 5D
P
5.3.9.2
After the tests
No any hazards
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
P
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
P
6.1.1
Protection from hazardous voltages
P
6.1.2
Separation of the telecommunication network from earth
P
6.1.2.1
Requirements
N
Supply voltage (V) ................................................ :
Current in the test circuit (mA) ............................ :
6.1.2.2
Exclusions ............................................................ :
P
6.2
Protection of equipment users from overvoltages on telecommunication networks
N
Page 21 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
6.2.1
Separation requirements
N
6.2.2
Electric strength test procedure
N
6.2.2.1
Impulse test
N
6.2.2.2
Steady-state test
N
6.2.2.3
Compliance criteria
N
6.3
Protection of the telecommunication wiring system from overheating
N
Max. output current (A) ......................................... :
No telecommunication wiring
system
Current limiting method ........................................ :
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N
7.1
General
No cable distribution system
N
7.2
Protection of cable distribution system service
persons, and users of other equipment connected to
the system, from hazardous voltages in the
equipment
N
7.3
Protection of equipment users from overvoltages on
the cable distribution system
N
7.4
Insulation between primary circuits and cable
distribution systems
N
7.4.1
General
N
7.4.2
Voltage surge test
N
7.4.3
Impulse test
N
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N
A.1
Flammability test for fire enclosures of movable
equipment having a total mass exceeding 18 kg,
and of stationary equipment (see 4.7.3.2)
N
A.1.1
Samples ................................................................ :
Wall thickness (mm) ............................................. :
A.1.2
Conditioning of samples; temperature (C) .......... :
N
A.1.3
Mounting of samples ............................................ :
N
A.1.4
Test flame (see IEC 60695-11-3)
N
Flame A, B, C or D ............................................... :
A.1.5
Test procedure
N
A.1.6
Compliance criteria
N
Sample 1 burning time (s) ..................................... :
Sample 2 burning time (s) ..................................... :
Page 22 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Sample 3 burning time (s) ..................................... :
A.2
Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
N
A.2.1
Samples, material ................................................. :
Wall thickness (mm) ............................................. :
A.2.2
Conditioning of samples; temperature (°C) .......... :
N
A.2.3
Mounting of samples ............................................ :
N
A.2.4
Test flame (see IEC 60695-11-4)
N
Flame A, B or C .................................................... :
A.2.5
Test procedure
N
A.2.6
Compliance criteria
N
Sample 1 burning time (s) ..................................... :
Sample 2 burning time (s) ..................................... :
Sample 3 burning time (s) ..................................... :
A.2.7
Alternative test acc. to IEC 60695-11-5, cl. 5 and 9
N
Sample 1 burning time (s) ..................................... :
Sample 2 burning time (s) ..................................... :
Sample 3 burning time (s) ..................................... :
A.3
Hot flaming oil test (see 4.6.2)
N
A.3.1
Mounting of samples
N
A.3.2
Test procedure
N
A.3.3
Compliance criterion
N
B
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and
5.3.2)
N
B.1
General requirements
(see appended table 1.5.1)
N
Position ................................................................. :
Manufacturer ........................................................ :
Type ..................................................................... :
Rated values ....................................................... :
B.2
Test conditions
N
B.3
Maximum temperatures
N
B.4
Running overload test
N
B.5
Locked-rotor overload test
N
Test duration (days) ............................................. :
Electric strength test: test voltage (V) .................. :
Page 23 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
B.6
Running overload test for d.c. motors in secondary
circuits
P
B.6.1
General
N
B.6.2
Test procedure
N
B.6.3
Alternative test procedure
N
B.6.4
Electric strength test; test voltage (V) .................. :
N
B.7
Locked-rotor overload test for d.c. motors in
secondary circuits
(see appended table 5.3)
P
B.7.1
General
N
B.7.2
Test procedure
N
B.7.3
Alternative test procedure
N
B.7.4
Electric strength test; test voltage (V) ................. :
N
B.8
Test for motors with capacitors
N
B.9
Test for three-phase motors
N
B.10
Test for series motors
N
Operating voltage (V) ........................................... :
C
ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)
P
Position ................................................................. :
ETD34/TPT150A
Manufacturer ........................................................ :
(see appended tabel 1.5.1)
Type ..................................................................... :
(see appended tabel 1.5.1)
Rated values ....................................................... :
(see appended tabel 1.5.1)
Method of protection ............................................. :
Inherent
C.1
Overload test
(see appended tabel 5.3)
P
C.2
Insulation
P
Protection from displacement of windings ............ :
Bobbin, insulation tube,
insulaton tape
P
D
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
(see 5.1.4)
P
D.1
Measuring instrument
P
D.2
Alternative measuring instrument
N
E
ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)
N
F
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10 and Annex G)
P
Page 24 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
G
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
N
G.1
Clearances
N
G.1.1
General
N
G.1.2
Summary of the procedure for determining minimum
clearances
N
G.2
Determination of mains transient voltage (V)
N
G.2.1
AC mains supply .................................................. :
N
G.2.2
Earthed d.c. mains supplies ................................. :
N
G.2.3
Unearthed d.c. mains supplies ............................. :
N
G.2.4
Battery operation .................................................. :
N
G.3
Determination of telecommunication network
transient voltage (V) ............................................. :
N
G.4
Determination of required withstand voltage (V)
N
G.4.1
Mains transients and internal repetitive peaks ..... :
N
G.4.2
Transients from telecommunication networks ..... :
N
G.4.3
Combination of transients
N
G.4.4
Transients from cable distribution systems
N
G.5
Measurement of transient voltages (V)
N
a) Transients from a mains supply
N
For an a.c. mains supply
N
For a d.c. mains supply
N
b) Transients from a telecommunication network
N
G.6
Determination of minimum clearances ................. :
N
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N
J
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N
Metal(s) used ....................................................... :
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)
N
K.1
Making and breaking capacity
N
K.2
Thermostat reliability; operating voltage (V) ......... :
N
K.3
Thermostat endurance test; operating voltage (V)
.............................................................................. :
N
K.4
Temperature limiter endurance; operating voltage
(V) ......................................................................... :
N
K.5
Thermal cut-out reliability
N
Page 25 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
K.6
Stability of operation
N
L
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
P
L.1
Typewriters
N
L.2
Adding machines and cash registers
N
L.3
Erasers
N
L.4
Pencil sharpeners
N
L.5
Duplicators and copy machines
N
L.6
Motor-operated files
N
L.7
Other business equipment
See condition in appended
table 1.6.2
P
M
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N
M.1
Introduction
N
M.2
Method A
N
M.3
Method B
N
M.3.1
Ringing signal
N
M.3.1.1
Frequency (Hz) ..................................................... :
M.3.1.2
Voltage (V) ........................................................... :
M.3.1.3
Cadence; time (s), voltage (V) ............................. :
M.3.1.4
Single fault current (mA) ...................................... :
M.3.2
Tripping device and monitoring voltage ............... :
N
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
N
M.3.2.2
Tripping device
N
M.3.2.3
Monitoring voltage (V) .......................................... :
N
N
ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1,
7.3.2, 7.4.3 and Clause G.5)
N
N.1
ITU-T impulse test generators
N
N.2
IEC 60065 impulse test generator
N
P
ANNEX P, NORMATIVE REFERENCES
Q
ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)
P
- Preferred climatic categories ............................. :
(see appended tabel 1.5.1)
Varistor was apploved
P
Page 26 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
- Maximum continuous voltage ............................ :
P
- Combination pulse current ................................. :
P
Body of the VDR
Test according to IEC60695-11-5 ........................ :
P
Body of the VDR.
Flammability class of material ( min V-1) ............. :
P
R
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
N
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)
N
R.2
Reduced clearances (see 2.10.3)
N
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N
S.1
Test equipment
N
S.2
Test procedure
N
S.3
Examples of waveforms during impulse testing
N
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)
N
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
N
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
N
V.1
Introduction
N
V.2
TN power distribution systems
N
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N
W.1
Touch current from electronic circuits
N
W.1.1
Floating circuits
N
W.1.2
Earthed circuits
N
W.2
Interconnection of several equipments
N
W.2.1
Isolation
N
W.2.2
Common return, isolated from earth
N
W.2.3
Common return, connected to protective earth
N
Page 27 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS
(see clause C.1)
N
X.1
Determination of maximum input current
N
X.2
Overload test procedure
N
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N
Y.1
Test apparatus ...................................................... :
N
Y.2
Mounting of test samples ...................................... :
N
Y.3
Carbon-arc light-exposure apparatus ................... :
N
Y.4
Xenon-arc light exposure apparatus ..................... :
N
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
P
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
N
BB
ANNEX BB, CHANGES IN THE SECOND EDITION
CC
ANNEX CC, Evaluation of integrated circuit (IC) current limiters
N
CC.1
General
N
CC.2
Test program 1 ......................................................:
N
CC.3
Test program 2 ......................................................:
N
CC.4
Test program 3 ......................................................:
N
CC.5
Compliance ...........................................................:
N
DD
ANNEX DD, Requirements for the mounting means of rack-mounted
equipment
N
DD.1
General
N
DD.2
Mechanical strength test, variable N………………..:
N
DD.3
Mechanical strength test, 250N, including end
stops……………………………………………………:
N
DD.4
Compliance……………………………………………:
N
EE
ANNEX EE, Household and home/office document/media shredders
N
EE.1
General
N
EE.2
Markings and instructions
N
Use of markings or symbols…………………………:
N
Page 28 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Information of user instructions, maintenance and/or
servicing instructions…………………………:
N
EE.3
Inadvertent reactivation test…………………………:
N
EE.4
Disconnection of power to hazardous moving parts:
N
Use of markings or symbols…………………………:
N
EE.5
Protection against hazardous moving parts
N
Test with test finger (Figure 2A) ……………………:
N
Test with wedge probe (Figure EE1 and EE2) ……:
N
Page 29 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
1.5.1
TABLE: List of critical components
P
Object/part
No.
Manufacturer/
trademark
Type/
model
Technical data
Standard
(Edition /
year)
Mark(s) of
conformity1)
AC plug
Shenzhen HongPu
Electron Co., Ltd.
XTH-005
16A, 250V~
VDE 0620-1
VDE
40026370
Shenzhen Yuxin Wire
& Cable Co., Ltd.
YX-201
16A, 250V~
VDE 0620-1
VDE
40001445
Power cord
Shenzhen Baohing
Electric Wire
& Cable Manufacture
Co., Ltd.
H03VV-F
3G0.75mm2
HD 21.5
S3+A1+A2
VDE 103727
Shenzhen Yuxin Wire
& Cable Co., Ltd.
H03VV-F
3G0.75mm2
HD 21.5
S3+A1+A2
VDE
40012386
AC connector
Shenzhen HongPu
Electron Co., Ltd.
XTH-021
10A, 250V~
EN 60320-1
VDE
40025516
Shenzhen Yuxin Wire
& Cable Co., Ltd.
YX-210
10A, 250V~
EN 60320-1
VDE
40035945
Appliance Inlet
Tecx-Unions
Technology
Corporation
TU-301-AP
10A, 250VAC
EN 60320-1
VDE
40025582
Primary lead
wire & Earth
wire
Zhongshan Dongfeng
Zhoushishenlong
Electronic Wire Co.,
Ltd.
1015
105C, 600V, 18AWG,
VW-1
UL 758
UL E257280
Cable-Net Industries
Ltd.
1015
105C, 600V, 18AWG,
VW-1
UL 758
UL E198417
Various
1015
105C, 600V, 18AWG,
VW-1
UL 758
UL
Heat
shrinkable
tube
Dongguan Salipt Co.,
Ltd.
SALIPT S-
901-300
300V, 125C, VW-1
UL 224
UL E209436
Dongguan Quantai
Industrial Co., Ltd.
T-2
600V, 125C, VW-1
UL 224
UL E227336
Various
Various
300V, 125C, VW-1
UL 224
UL
Insulation
sheet on PCB
Mianyang Longhua
Film Co., Ltd.
PC-770,
PC-770F,
PC-770F-A
PC, V-0, 80C,
Min. 0.4mm
UL 94,
UL 746
UL E254551
Suzhou Omay Optical
Materials Co., Ltd.
SE42,
SE42B
PC, V-0, 80C,
Min. 0.4mm
UL 94,
UL 746
UL E249605
Various
Various
PC, V-0, 80C,
Min. 0.4mm
UL 94,
UL 746
UL
White glue on
PCB
Shen Zhen Bonic
Science &
Technology Co., Ltd.
Various
V-0, Min.130C
UL 94,
UL 746
UL E254560
Page 30 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Object/part
No.
Manufacturer/
trademark
Type/
model
Technical data
Standard
(Edition /
year)
Mark(s) of
conformity1)
AC
Connector
CN1
Zhejiang Jinda
Electronics Co., Ltd.
3.96T-02
V-0, 250Vac, 7A
UL 1977
UL E237523
Shenzhen Yong Feng
Ying Electronic Co.,
Ltd.
CS-1120
V-0, 250Vac, 7A
UL 1977
UL E241915
Shanghai Yueshen
Electronic Co., Ltd.
YSF6
V-0, 250Vac, 7A
UL 1977
UL E204074
Fuse F1
Dongguan Better
Electronics Technology
Co., Ltd.
932
T5AL250Vac
IEC 60127-1
IEC 60127-3
VDE
40033369
Shenzhen Lanson
Electronics Co. Ltd.
SMT
T5AL250Vac
IEC 60127-1
IEC 60127-3
VDE
40013102
Cooper Bussmann LLC
SS-5
T5AL250Vac
IEC 60127-1
IEC 60127-3
VDE
40015513
Dongguan Hongda
Electronic Technology
Co., Ltd.
2009
T5AL250Vac
IEC 60127-1
IEC 60127-3
VDE
40028260
Various
Various
T5AL250Vac
IEC 60127-1
IEC 60127-3
VDE
Varistor V1
Centra Science Corp.
CNR-
14D471K
470Vac, 85C
IEC61051-1
IEC61051-2
VDE
40008220
Lien Shun Electronics
Co., Ltd.
14D471K
470Vac, 85C
IEC61051-1
IEC61051-2
VDE
40005858
Thinking Electronic
Industrial Co., Ltd.
TVR14471-
D
470Vac, 85C
IEC61051-1
IEC61051-2
VDE
40021243
Thinking Electronic
Industrial Co., Ltd.
TVR14471
470Vac, 85C
IEC61051-1
IEC61051-2
VDE 005944
Brightking (Shenzhen)
Co., Ltd.
471KD14
470Vac, 85C
IEC61051-1
IEC61051-2
VDE
40027827
Shaanxi Huaxing
electronic group Co.,
Ltd.
MYG20G1
4K471
470Vac, 85C
IEC61051-1
IEC61051-2
VDE
40018747
Shantou High-New
Technology Dev. Zone
Songtian Enterprise
Co., Ltd.
STE-
14D471K
470Vac, 85C
IEC61051-1
IEC61051-2
VDE
40023049
Y1 capacitor
CY3
Guangdong South
Hongming Electronic
Science and
Technology Co., Ltd.
F
3300pF 250Vac,
125°C
IEC 60384-14
VDE
40036393
Shantou High-New
Technology Dev. Zone
Songtian Enterprise
Co., Ltd.
CD
3300pF 250Vac,
125°C
IEC 60384-14
VDE
40025754
Page 31 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Object/part
No.
Manufacturer/
trademark
Type/
model
Technical data
Standard
(Edition /
year)
Mark(s) of
conformity1)
Shaanxi Huaxing
Electronic
Development Co. Ltd.
CT7Y1
3300pF 400Vac,
125°C
IEC 60384-14
VDE
40015542
Shenzhen Teruixiang
Electronic Co, Ltd.
TY-Series
(TYB,TYE,
TYF)
3300pF 400Vac,
125°C
IEC 60384-14
VDE
40023136
Dongguan Easy-gather
Electronic Co., Ltd.
DCF
3300pF 400Vac,
125°C
IEC 60384-14
VDE
40022942
Jya-Nay Co., Ltd.
JN
3300pF, Min.250Vac,
12C
EN 60384-14
TÜV
Rheinland
Cert. No.:
69242987
Y2 capacitor
CY4,CY5
Guangdong South
Hongming Electronic
Science and
Technology Co., Ltd.
F
3300pF 250Vac,
125°C
IEC 60384-14
VDE
40036393
Shantou High-New
Technology Dev. Zone
Songtian Enterprise
Co., Ltd.
CE
3300pF 250Vac,
125°C
IEC 60384-14
VDE
40025748
Shaanxi Huaxing
Electronic
Development Co. Ltd.
CT7Y2
3300pF 400Vac,
125°C
IEC 60384-14
VDE
40032125
Dongguan Easy-gather
Electronic Co., Ltd.
DCF
3300pF 250Vac,
125°C
IEC 60384-14
VDE
40015758
Y2 capacitor
CY1,CY2,
Guangdong South
Hongming Electronic
Science and
Technology Co., Ltd.
F
2200pF 250Vac,
125°C
IEC 60384-14
VDE
40036393
Shantou High-New
Technology Dev. Zone
Songtian Enterprise
Co., Ltd.
CE
2200pF 250Vac,
125°C
IEC 60384-14
VDE
40025748
Shaanxi Huaxing
Electronic
Development Co. Ltd.
CT7Y2
2200pF 400Vac,
125°C
IEC 60384-14
VDE
40032125
Dongguan Easy-gather
Electronic Co., Ltd.
DCF
2200pF 250Vac,
125°C
IEC 60384-14
VDE
40015758
X2 capacitor
CX1, CX2
Tenta Electric Industrial
Co. Ltd.
MEX
0.47μF 275Vac
IEC 60384-14
VDE 119119
Dain Electronics Co.,
Ltd.
MPX/NPX/
MEX
0.47μF 275Vac
IEC 60384-14
VDE
40018798
Shantou High-New
Technology Dev. Zone
Songtian Enterprise
Co., Ltd.
MPX
0.47μF 275Vac
IEC 60384-14
VDE
40034679
Page 32 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Object/part
No.
Manufacturer/
trademark
Type/
model
Technical data
Standard
(Edition /
year)
Mark(s) of
conformity1)
Shenzhen Su Rong
Capacitors Co., Ltd.
MPX/MKP
0.47μF 275Vac
IEC 60384-14
VDE
40008924
Dongguan Easy-gather
Electronic Co., Ltd.
MKP-X2
0.47μF 275Vac
IEC 60384-14
VDE
40022258
Thermistor
TR1
Nanjing Shiheng
Electronics Co., Ltd.
MF72-
10D11
10Ω,3A
IEC60950
UL1434
UL E241319
Thinking Electronic
Industrial Co., Ltd.
SCK-103
10Ω,3A
IEC60950
UL1434
UL E138827
Ophtocoupler
U1
Everlight Electronics
Co., Ltd.
EL817 V
Dti0.4mm,
Cl6.0mm,
Cr7.5mm, 110°C
EN 60747-5-5
VDE 132249
Bright Led Electronics
Corp.
BPC-817
Dti0.4mm,
Cr=8.0mm, Cl=7.6mm,
100°C
IEC 60747-5-
2
VDE
40007240
Lite-On Technology
Corporation
LTV-817
Dti>0.5mm, Int.
Cr>6.0mm, Ext.
Cr>7.5mm, 100C
EN 60747-5-2
VDE
40015248
Shenzhen Orient
Components Co., Ltd.
ORPC-817
Dti0.4mm,
Cl6.0mm,
Cr7.5mm, 100°C
EN 60747-5-2
VDE
40029733
Inductors
LF1, LF2
Shenzhen Topow
Electronics Co., Ltd.
T18*10*7
24mH
EN 60950-1
Tested within
appliance
Winding of
LF1, LF2
Pacific Electric Wire &
Cable (Shenzhen) Co.,
Ltd.
UEW/U
13C
UL1446
UL E201757
Insulation
tape of LF1,
LF2
Jingjiang Yahua
Pressure Sensitive
Glue Co., Ltd.
PZ
CZ
130°C
UL 510
UL E165111
Inductors L1
Shenzhen Topow
Electronics Co., Ltd.
T68-26A
160μH
EN 60950-1
Tested within
appliance
Winding of L1
Pacific Electric Wire &
Cable (Shenzhen) Co.,
Ltd.
UEW/U
13C
UL1446
UL E201757
Transformer
T1
Shenzhen Topow
Electronics Co., Ltd.
EI2820/TP
T150A
Primary:
N1:
Φ0.1mm*40P*44TS
Secondary:
N4: Φ0.3mm*1P*5TS
EN 60950-1
Tested within
appliance
Bobbin of T1
Chang Chun Plastics
Co., Ltd.
T375J
V-0, 150°C
UL 746,
UL 94
UL E59481
Insulation
tape of T1
Jingjiang Yahua
Pressure Sensitive
Glue Co., Ltd.
PZ
CZ
130°C
UL 510
UL E165111
Winding of T1
Pacific Electric Wire &
UEW/U
13C
UL 1446
UL E201757
Page 33 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Object/part
No.
Manufacturer/
trademark
Type/
model
Technical data
Standard
(Edition /
year)
Mark(s) of
conformity1)
Cable (Shenzhen) Co.,
Ltd.
Varnish of T1
John C Dolph Co.
BC-346A
20C
UL 1446
UL E317427
Insulating
tube of T1
Great Holding Industrial
Co., Ltd.
TFT
300V, 200°C
UL 224
UL E156256
Transformer
T2
Shenzhen Topow
Electronics Co., Ltd.
ETD34/TP
T150A
Primary:
N1:
Φ0.1mm*40P*44TS
N4: Φ0.3mm*1P*4TS
Secondary:
N2:
Φ0.1mm*50P*12TS
N3:
Φ0.1mm*50P*12TS
Class B
EN 60950-1
Tested within
appliance
Bobbin of T2
Chang Chun Plastics
Co., Ltd.
T375J
V-0, 150°C
UL 746,
UL 94
UL E59481
Insulation
tape of T2
Jingjiang Yahua
Pressure Sensitive
Glue Co., Ltd.
PZ
130°C
UL 510
UL E165111
Winding of T2
Pacific Electric Wire &
Cable (Shenzhen) Co.,
Ltd.
UEW/U
13C
UL 1446
UL E201757
Insulating
tube of T2
Great Holding Industrial
Co., Ltd.
TFT
300V, 200°C
UL 224
UL E156256
Varnish of T2
John C Dolph Co.
BC-346A
20C
UL 1446
UL E317427
Power board
PCB
Sources Merge
Industrial Ltd.
TCL1008F
R
V-0, 130°C
UL 94,
UL 746
UL E74729
Boluo Eversun
Electronics Plant
YY-D
V-0, 130°C
UL 94,
UL 746
UL E250664
Various
Various
V-0, 130°C
UL 94,
UL 746
UL
Other PCB
Goldenmax
International
Technology (Zhuhai)
Ltd.
Various
V-0, 130°C
UL 94,
UL 746
UL E330731
Various
Various
V-0, 130°C
UL 94,
UL 746
UL
Supplementary information:/
Page 34 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
1.6.2
TABLE: Electrical data (in normal conditions)
P
Cond.
U (V)
Hz
I (A)
Irated (A)
P (W)
Fuse #
Ifuse (A)
Condition/status
01
90.0
50
1.25
--
113.0
F1
1.25
Normal operation
02
100.0
50
1.13
2.2
112.4
F1
1.13
03
240.0
50
0.533
2.2
109.4
F1
0.533
04
254.4
50
0.543
--
110.2
F1
0.543
05
90.0
60
1.24
--
112.0
F1
1.24
06
100.0
60
1.12
2.2
112.2
F1
1.12
07
240.0
60
0.525
2.2
108.6
F1
0.525
08
254.4
60
0.540
--
109.2
F1
0.540
Supplementary information: --
2.1.1.5 c) 1)
TABLE: max. V, A, VA test
P
Voltage (rated)
(V)
Current (rated)
(A)
Voltage (max.)
(V)
Current (max.)
(A)
VA (max.)
(VA)
--
--
52.87Vd.c.
3.86
203.6
Supplementary information: Output of power supply PCB.
2.1.1.5 c)
2)
TABLE: stored energy
N
Capacitance C (µF)
Voltage U (V)
Energy E (J)
--
--
--
supplementary information:
2.2
TABLE: evaluation of voltage limiting components in SELV circuits
P
Component (measured between)
max. voltage (V)
(normal operation)
Voltage Limiting Components
V peak
V d.c.
Output of power supply PCB
--
52.87
--
Fault test performed on voltage limiting components
Voltage measured (V) in SELV circuits
(V peak or V d.c.)
S-C diode D12
Unit shut down, no output U=0
Remark: Output of power supply PCB
Page 35 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
2.4.2
TABLE: limited current circuit measurement
P
Location
Voltage
(V)
Current
(mA)
Freq.
(Hz)
Limit
(mA)
Comments
Between Y capacitor CY3
6.94
3.47
248K
173.6
CY3: 3300PF
Remark:
2.5
TABLE: limited power sources
N
Circuit output tested: Output of power supply PCB
Measured Uoc (V) with all load circuits
disconnected:
Isc (A)
VA
Meas.
Limit
Meas.
Limit
--
--
--
--
--
supplementary information:
2.10.2
Table: working voltage measurement
P
Location
RMS voltage (V)
Peak voltage (V)
Comments
Transformer T2 pin 1- pin 8
240
339
--
Transformer T2 pin 1- pin 9
240
339
--
Transformer T2 pin 1- pin 10
240
339
--
Transformer T2 pin 2- pin 8
240
339
--
Transformer T2 pin 2- pin 9
240
339
--
Transformer T2 pin 2- pin 10
240
339
--
Transformer T2 pin 5- pin 8
246
340
--
Transformer T2 pin 5- pin 9
240
339
--
Transformer T2 pin 5- pin 10
240
339
--
Transformer T2 pin 6- pin 8
311
448
Max. RMS & Peak of T2
Transformer T2 pin 6- pin 9
240
339
--
Transformer T2 pin 6- pin 10
242
408
--
Optocoupler U1 pin 1- pin 3
240
339
--
Optocoupler U1 pin 1- pin 4
240
339
Max. RMS & Peak of U1
Optocoupler U1 pin 2- pin 3
240
339
--
Optocoupler U1 pin 2- pin 4
240
339
--
Y capacitor CY3 pin 1- pin 2
240
339
Max. RMS & Peak of CY3
Page 36 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
supplementary information:
2.10.3 and
2.10.4
TABLE: Clearance and creepage distance measurements
P
Clearance (cl) and creepage
distance (cr) at/of/between:
U peak
(V)
U r.m.s.
(V)
Required cl
(mm)
cl
(mm)
Required cr
(mm)
cr
(mm)
L and N
339
240
1.5
2.4
2.5
3.8
Two pins of F1
339
240
2.0
2.1
2.5
3.2
Live part and earth
339
240
2.0
3.2
2.5
3.2
Two pins of Capacitor CY1
339
240
2.0
4.8
2.5
4.8
Two pins of Capacitor CY2
339
240
2.0
3.2
2.5
3.2
Two pins of Capacitor CY3
339
240
4.0
7.9
5.0
7.9
Two pins of Capacitor CY4
339
240
2.0
4.2
2.5
4.2
Two pins of Capacitor CY5
339
240
2.0
4.2
2.5
4.2
Optocoupler U1 (Pri.-Sec.)
339
240
4.0
7.9
5.0
7.9
Transformer T2 (Pri.-Sec.) on
PCB
448
311
4.3
10.7
6.3
10.7
Transformer T2 (Pri.-Sec.)
448
311
4.3
8.9
6.3
8.9
Live part and Sec.
339
240
2.0
12.2
2.5
12.2
Live part and metal enclosure
339
240
2.0
3.2
2.5
3.2
Supplementary information: --
2.10.5
TABLE: Distance through insulation measurements
P
Distance through insulation (DTI) at/of:
U peak
(V)
U rms
(V)
Test
voltage (V)
Required
DTI (mm)
DTI
(mm)
Transformer bobbin
448
311
3000
0.4
0.8
Optocoupler U1
339
240
3000
0.4
>0.4
Supplementary information: --
Page 37 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
4.3.8
TABLE: Batteries
N
The tests of 4.3.8 are applicable only when appropriate battery
data is not available
No battery
N
Is it possible to install the battery in a reverse polarity position?
N
Non-rechargeable batteries
Rechargeable batteries
Discharging
Un-
intentional
charging
Charging
Discharging
Reversed
charging
Meas.
current
Manuf.
Specs.
Meas.
current
Manuf.
Specs.
Meas.
current
Manuf.
Specs.
Meas.
current
Manuf.
Specs.
Max.
current
during
normal
condition
--
--
--
--
--
Max.
current
during
fault
condition
--
--
--
--
--
Test results:
--
Verdict
- Chemical leaks
--
N
- Explosion of the battery
--
N
- Emission of flame or expulsion of molten metal
--
N
- Electric strength tests of equipment after completion of tests
--
N
Remark: --
Page 38 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
4.3.8
TABLE: Batteries
N
Battery category ........................................... :
--
Manufacturer ............................................... :
--
Type / model ................................................ :
--
Voltage ........................................................ :
--
Capacity ....................................................... :
--
Tested and Certified by (incl. Ref. No.) ....... :
--
Circuit protection diagram:
MARKINGS AND INSTRUCTIONS (1.7.12, 1.7.15)
Location of replaceable battery
--
Language(s) …………………………………….:
--
Close to the battery …………………………….:
--
In the servicing instructions ……………………:
--
In the operating instructions …………………..:
--
Page 39 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
4.5.1
TABLE: maximum temperatures
P
Supply voltage (V) ............................
90.0
254.4
Ambient Tmin (C) ..............................
24.0
24.4
Ambient Tmax (C) .............................
24.5
24.8
Maximum measured temperature T
of part/at:
T (C)
Allowed Tmax (C)
No. 05
No. 04
Y- Capacitor CY1
61.3
47.4
125+24-40=109
Varistors V1
65.2
52.2
85+24-40=69
X-Capacitor CX1
71.8
54.9
100+24-40=84
Inductors LT1 winding
78.9
56.1
110+24-40=94
Inductors LT2 winding
80.8
55.4
110+24-40=94
X-Capacitor CX2
79.0
56.5
100+24-40=84
PCB near BD1
81.1
59.6
130+24-40=114
PCB near D2
80.8
63.1
130+24-40=114
Capacitor C2
73.1
61.1
105+24-40=89
Inductors L1 winding
76.0
58.7
110+24-40=94
PCB near Q1
67.3
61.6
130+24-40=114
Transformer T1 bobbin
88.4
66.7
Reference
Transformer T1 winding
89.1
67.9
110+24-40=94
Y- Capacitor CY3
54.5
53.0
125+24-40=109
Optocoupler U1
58.3
57.0
100+24-40=84
Transformer T2 Pri. winding
75.1
73.7
110+24-40=94
Transformer T2 Sec. winding
76.4
76.2
110+24-40=94
Transformer T2 bobbin
75.7
75.4
Reference
Capacitor C28
64.7
64.0
105+24-40=89
PCB near D12
64.1
64.2
130+24-40=114
PCB near IC (signal PCB)
53.5
52.4
130+24-40=114
Inductors L6 winding
69.3
67.3
110+24-40=94
Capacitor C1
58.8
57.4
105+24-40=89
Internal wire of Pri.
62.9
50.8
105+24-40=89
Internal wire of Sec.
52.9
52.2
80+24-40=64
Power supply cord
26.7
26.6
75+24-40=59
Metal enclosure
42.0
37.4
70+24-40=54
Inlet surface
36.0
34.4
85+24-40=69
Page 40 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Heat-sink
93.0
65.1
Reference
Network terminal
37.4
37.1
70+24-40=54
Temperature T of winding:
t1C)
R1 ()
t2C)
R2 ()
Allowed
Tmax (C)
Insulation class
--
--
--
--
--
--
Supplementary information: * The winding permitted temperature rise would be reduced 10K while the
temperature rise measured for thermal-coupler method.
Allowed Tmax=Tmax+Tamb-Tma, Tamb=24C, Tma=40C.
The max operated temperature is 40C which is specified by manufacturer
4.5.5
TABLE: Ball pressure test of thermoplastic parts
P
Allowed impression diameter (mm) ..................... :
2 mm
Part
Test temperature
(C)
Impression diameter
(mm)
Bobbin of T1
125
1.03
Bobbin of T2
125
0.87
AC terminal CN1
125
1.14
Supplementary information: --
4.7
TABLE: Resistance to fire
P
Part
Manufacturer of
material
Type of material
Thickness
(mm)
Flammability
class
Evidence
Bobbin of T1
Chang Chun Plastics
Co., Ltd.
T375J
3.0
V-0
UL E59481
Bobbin of T2
Chang Chun Plastics
Co., Ltd.
T375J
0.9
V-0
UL E59481
AC terminal CN1
Zhejiang Jinda
Electronics Co., Ltd.
3.96T-02
2.46
V-0
UL E237523
Material of supply
PCB
Various
Various
1.6
V-0
UL
Supplementary information: --
5.1
TABLE: touch current measurement
P
Measured between:
Measured
(mA)
Limit
(mA)
Comments/conditions
L/N and metal enclosure
1.38
3.5
--
supplementary information: Input voltage: 254.4V, 60Hz
Page 41 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
5.2
TABLE: Electric strength tests, impulse tests and voltage surge tests
P
Test voltage applied between:
Voltage shape
(AC, DC,
impulse, surge)
Test
voltage
(V)
Breakdown
Yes / No
Between L-N and metal enclosure & terminal
AC
1500
No
Transformer T2 primary and secondary
AC
3000
No
1 layer insulation tape of transformer
AC
3000
No
Between L and N without fuse F1
AC
1500
No
Supplementary information: --
5.3
TABLE: Fault condition tests
P
Ambient temperature (C) .................................... :
21.5-23.4
Power source for EUT: Manufacturer, model/type,
output rating ......................................................... :
--
Component
No.
Fault
Supply
voltage (V)
Test
time
Fuse
#
Fuse
current (A)
Observation
T2 output
O-L
254.4V
300
mins
F1
0.907
No hazard occurred and no
high temperature occurred.
The max. temperature of L1 is
75.3C.
The max. temperature of T1 is
89.7C.
The max. temperature of T2 is
108.8C.
The max. over-load current is
3.9A, over 3.9A, the unit shut
down.
T2 output
S-C
254.4V
30mins
F1
0.130
0.127
No hazard occurred and no
high temperature occurred.
Unit shut down.
D2 Pin 2-3
S-C
254.4V
30mins
F1
0.133
0.130
No hazard occurred and no
high temperature occurred.
Unit shut down.
D2 Pin 1-2
S-C
254.4V
30mins
F1
0.143
0.132
No hazard occurred and no
high temperature occurred.
Unit shut down.
Capacitor
C20
S-C
254.4V
30mins
F1
0.132
0.130
No hazard occurred and no
high temperature occurred.
Unit shut down.
Q6 Pin 1-2
S-C
254.4V
1s
F1
0
No hazard occurred and no
high temperature occurred.
Fuse F1 opened immediately.
Q5 Pin 2-3
S-C
254.4V
1s
F1
0
No hazard occurred and no
high temperature occurred.
Fuse F1 opened immediately.
Page 42 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Capacitor C2
S-C
254.4V
1s
F1
0
No hazard occurred and no
high temperature occurred.
Fuse F1 opened immediately.
Q2
S-C
254.4V
1s
F1
0
No hazard occurred and no
high temperature occurred.
Fuse F1 opened immediately.
BD1
S-C
254.4V
1s
F1
0
No hazard occurred and no
high temperature occurred.
Fuse F1 opened immediately.
Supplementary information: S-C is abbreviation of shorted- circuit. O-L is abbreviation of over-load.
The limit of T1 and T2 winding: 165+21.5-40=146.5C
C.2
TABLE: transformers
P
Loc.
Tested insulation
Working
voltage
peak / V
(2.10.2)
Working
voltage
rms / V
(2.10.2)
Required
electric
strength
(5.2)
Required
clearance /
mm
(2.10.3)
Required
creepage
distance /
mm
(2.10.4)
Required
distance
thr. insul.
(2.10.5)
T2 Pri. to
Sec.
Reinforced insulation
448
311
3000Vac
4.3
6.3
*
Loc.
Tested insulation
Test
voltage/
V
Measured
clearance /
mm
Measured
creepage
dist./ mm
Measured
distance
thr. insul. /
mm;
number of
layers
T2 Pri. to
Sec.
Reinforced insulation
3000Vac
8.9
8.9
0.87mm
2 layers
supplementary information:
Page 43 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
C.2
TABLE: transformers
P
Transformer
Page 44 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 CENELEC COMMON MODIFICATIONS
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause
Requirement + Test
Result - Remark
Verdict
Clauses, subclauses, notes, tables and figures which are additional to those in
IEC60950-1 and it´s amendmets are prefixed “Z”
P
Contents
(A2:2013)
Add the following annexes:
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Annex ZB (normative) Special national conditions
Annex ZD (informative) IEC and CENELEC code designations for
flexible cords
P
General
Delete all the “country” notes in the reference document (IEC 60950-1:2005)
according to the following list:
1.4.8 Note 2 1.5.1 Note 2 & 3 1.5.7.1 Note
1.5.8 Note 2 1.5.9.4 Note 1.7.2.1 Note 4, 5 & 6
2.2.3 Note 2.2.4 Note 2.3.2 Note
2.3.2.1 Note 2 2.3.4 Note 2 2.6.3.3 Note 2 & 3
2.7.1 Note 2.10.3.2 Note 2 2.10.5.13 Note 3
3.2.1.1 Note 3.2.4 Note 3. 2.5.1 Note 2
4.3.6 Note 1 & 2 4.7 Note 4 4.7.2.2 Note
4.7.3.1Note 2 5.1.7.1 Note 3 & 4 5.3.7 Note 1
6 Note 2 & 5 6.1.2.1 Note 2 6.1.2.2 Note
6.2.2 Note 6.2.2.1 Note 2 6.2.2.2 Note
7.1 Note 3 7.2 Note 7.3 Note 1 & 2
G.2.1 Note 2 Annex H Note 2
P
General
(A1:2010)
Delete all the “country” notes in the reference document (IEC 60950-
1:2005/A1:2010) according to the following list:
1.5.7.1 Note 6.1.2.1 Note 2
6.2.2.1 Note 2 EE.3 Note
P
General
(A2:2013)
Delete all the “country” notes in the reference document (IEC 60950-
1:2005/A2:2013) according to the following list:
2.7.1 Note * 2.10.3.1 Note 2
6.2.2. Note
* Note of secretary: Text of Common Modification remains unchanged.
P
1.1.1
(A1:2010)
Replace the text of NOTE 3 by the following.
NOTE 3 The requirements of EN 60065 may also be used to meet safety requirements for multimedia
equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. For television sets EN
60065 applies.
P
Page 45 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause
Requirement + Test
Result - Remark
Verdict
1.3.Z1
Add the following subclause:
1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and constructed
as to present no danger when used for its intended
purpose, either in normal operating conditions or
under fault conditions, particularly providing
protection against exposure to excessive sound
pressures from headphones or earphones.
NOTE Z1 A new method of measurement is described in
EN 50332-1, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part
1: General method for “one package equipment”, and in
EN 50332-2, Sound system equipment: Headphones and
earphones associated with portable audio equipment -
Maximum sound pressure level measurement
methodology and limit considerations - Part 2: Guidelines
to associate sets with headphones coming from different
manufacturers.
Not such equiipment.
N
(A12:2011)
In EN 60950-1:2006/A12:2011
Delete the addition of 1.3.Z1 / EN 60950-1:2006
Delete the definition 1.2.3.Z1 / EN 60950-1:2006
/A1:2010
N
1.5.1
(Added
info*)
Add the following NOTE:
NOTE Z1 The use of certain substances in electrical and
electronic equipment is restricted within the EU: see
Directive 2002/95/EC.
New Directive 2011/65/11 *
Added
P
1.7.2.1
(A1:2010)
In addition, for a PORTABLE SOUND SYSTEM, the
instructions shall include a warning that excessive
sound pressure from earphones and headphones can
cause hearing loss.
N
1.7.2.1
(A12.2011)
In EN 60950-1:2006/A12:2011
Delete NOTE Z1 and the addition for Portable Sound
System.
Add the following clause and annex to the existing
standard and amendments.
N
Page 46 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Zx Protection against excessive sound pressure from personal music players
N
Zx.1 General
This sub-clause specifies requirements for
protection against excessive sound pressure from
personal music players that are closely coupled to
the ear. It also specifies requirements for earphones
and headphones intended for use with personal
music players.
A personal music player is a portable equipment for
personal use, that:
is designed to allow the user to listen to recorded or
broadcast sound or video; and
primarily uses headphones or earphones that can
be worn in or on or around the ears; and
allows the user to walk around while in use.
NOTE 1 Examples are hand-held or body-worn portable CD
players, MP3 audio players, mobile phones with MP3 type
features, PDA‟s or similar equipment.
A personal music player and earphones or
headphones intended to be used with personal
music players shall comply with the requirements of
this sub-clause.
The requirements in this sub-clause are valid for
music or video mode only.
The requirements do not apply:
while the personal music player is connected to
an external amplifier; or
while the headphones or earphones are not used.
NOTE 2 An external amplifier is an amplifier which is not part of
the personal music player or the listening device, but which is
intended to play the music as a standalone music player.
The requirements do not apply to:
hearing aid equipment and professional
equipment;
NOTE 3 Professional equipment is equipment sold through
special sales channels. All products sold through normal
electronics stores are considered not to be professional
equipment.
analogue personal music players (personal music
players without any kind of digital processing
of the sound signal) that are brought to the
market before the end of 2015.
NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that within a few
years it will no longer exist. This exemption will not be extended
to other technologies.
For equipment which is clearly designed or intended
for use by young children, the limits of EN 71-1
apply.
N
Page 47 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Zx.2 Equipment requirements
No safety provision is required for equipment that
complies with the following:
equipment provided as a package (personal music
player with its listening device), where
the acoustic output LAeq,T is ≤ 85 dBA
measured while playing the fixed “programme
simulation noise” as described in EN 50332-1; and
a personal music player provided with an
analogue electrical output socket for a listening
device, where the electrical output is ≤ 27 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
as described in EN 50332-1.
NOTE 1 Wherever the term acoustic output is used in this
clause, the 30 s A-weighted equivalent sound pressure level
LAeq,T is meant. See also Zx.5 and Annex Zx.
N
All other equipment shall:
N
a) protect the user from unintentional acoustic
outputs exceeding those mentioned above; and
N
b) have a standard acoustic output level not
exceeding those mentioned above, and automatically
return to an output level not exceeding those
mentioned above when the power is switched off; and
N
c) provide a means to actively inform the user of the
increased sound pressure when the equipment is
operated with an acoustic output exceeding those
mentioned above. Any means used shall be
acknowledged by the user before activating a mode
of operation which allows for an acoustic output
exceeding those mentioned above. The
acknowledgement does not need to be repeated
more than once every 20 h of cumulative listening
time; and
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening
time, independent how often and how long the personal music
player has been switched off.
N
d) have a warning as specified in Zx.3; and
N
e) not exceed the following:
1) equipment provided as a package (player
with Its listening device), the acoustic output
shall be ≤ 100 dBA measured while playing the
fixed “programme simulation noise” described
in EN 50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device, the electrical output shall be ≤ 150 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
described in EN 50332-1.
N
Page 48 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
For music where the average sound pressure (long
term LAeq,T) measured over the duration of the song
is lower than the average produced by the
programme simulation noise, the warning does not
need to be given as long as the average sound
pressure of the song is below the basic limit of 85
dBA. In this case T becomes the duration of the
song.
NOTE 4 Classical music typically has an average sound pressure
(long term LAeq,T) which is much lower than the average
programme simulation noise. Therefore, if the player is capable
to analyse the song and compare it with the programme
simulation noise, the warning does not need to be given as long
as the average sound pressure of the song is below the basic
limit of 85 dBA.
For example, if the player is set with the programme simulation
noise to 85 dBA, but the average music level of the song is only
65 dBA, there is no need to give a warning or ask an
acknowledgement as long as the average sound level of the song
is not above the basic limit of 85 dBA.
N
Zx.3 Warning
The warning shall be placed on the equipment, or on
the packaging, or in the instruction manual and shall
consist of the following:
the symbol of Figure 1 with a minimum height of
5 mm; and
the following wording, or similar:
“To prevent possible hearing damage, do not listen
at high volume levels for long periods.”
Figure 1 Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given
through the equipment display during use, when the
user is asked to acknowledge activation of the
higher level.
N
Zx.4 Requirements for listening devices (headphones and earphones)
N
Page 49 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Zx.4.1 Wired listening devices with analogue
input
With 94 dBA sound pressure output LAeq,T, the input
voltage of the fixed “programme simulation noise”
described in EN 50332-2 shall be ≥ 75 mV.
This requirement is applicable in any mode where
the headphones can operate (active or
passive), including any available setting (for example
built-in volume level control).
NOTE The values of 94 dBA 75 mV correspond with 85dBA
27 mV and 100 dBA 150 mV.
N
Zx.4.2 Wired listening devices with digital input
With any playing device playing the fixed
“programme simulation noise” described in EN
50332-1 (and respecting the digital interface
standards, where a digital interface standard exists
that specifies the equivalent acoustic level), the
acoustic output LAeq,T of the listening device shall be
≤ 100 dBA.
This requirement is applicable in any mode where
the headphones can operate, including any available
setting (for example built-in volume level control,
additional sound feature like equalization, etc.).
NOTE An example of a wired listening device with digital input is
a USB headphone.
N
Zx.4.3 Wireless listening devices
In wireless mode:
with any playing and transmitting device playing
the fixed programme simulation noise described
in EN 50332-1; and
respecting the wireless transmission standards,
where an air interface standard exists that
specifies the equivalent acoustic level; and
with volume and sound settings in the listening
device (for example built-in volume level control,
additional sound feature like equalization, etc.)
set to the combination of positions that
maximize the measured acoustic output for the
abovementioned programme simulation noise,
the acoustic output LAeq,T of the listening device
shall be ≤ 100 dBA.
NOTE An example of a wireless listening device is a Bluetooth
headphone.
N
Zx.5 Measurement methods
Measurements shall be made in accordance with EN
50332-1 or EN 50332-2 as applicable. Unless
stated otherwise, the time interval T shall be 30 s.
NOTE Test method for wireless equipment provided without
listening device should be defined.
N
Page 50 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
2.7.1
Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-circuits
and earth faults in PRIMARY CIRCUITS, protective
devices shall be included either as integral parts of
the equipment or as parts of the building installation,
subject to the following, a), b) and c):
a) except as detailed in b) and c), protective devices
necessary to comply with the requirements of 5.3
shall be included as parts of the equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and earth
fault protection may be provided by protective
devices in the building installation;
Replaced.
P
c) it is permitted for PLUGGABLE EQUIPMENT
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent and
short-circuit protection in the building installation,
provided that the means of protection, e.g. fuses or
circuit breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so state,
except that for PLUGGABLE EQUIPMENT TYPE A
the building installation shall be regarded as
providing protection in accordance with the rating of
the wall socket outlet.
Not such equipment
N
2.7.2
This subclause has been declared „void‟.
N
3.2.3
Delete the NOTE in Table 3A, and delete also in this
table the conduit sizes in parentheses.
N
3.2.5.1
Replace “60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or
H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or
H05 VVH2-F2”.
In Table 3B, replace the first four lines by the
following:
Up to and including 6 | 0,75 a) |
Over 6 up to and including 10| (0,75) b) 1,0 |
Over 10 up to and including 16| (1,0) c) 1,5 |
In the conditions applicable to Table 3B delete the
words “in some countries” in condition a).
In NOTE 1, applicable to Table 3B, delete the
second sentence.
N
3.2.5.1
(A2:2013)
NOTE Z1 The harmonised code designations
corresponding to the IEC cord types are given in Annex ZD
N
Page 51 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
3.3.4
In Table 3D, delete the fourth line: conductor sizes
for 10 to 13 A, and replace with the following:
Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to 4
|
Delete the fifth line: conductor sizes for 13 to 16 A
N
4.3.13.6
(A1:2010)
Replace the existing NOTE by the following:
NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the limitation
of exposure of the general public to electromagnetic fields
0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and safety
requirements regarding the exposure of workers to risks
arising from physical agents (artifical optical radiation).
Added
N
Standards taking into account mentioned
Recommendation and Directive which demonstrate
compliance with the applicable EU Directive are indicated
in the OJEC.
N
Annex H
Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall not
exceed 1 μSv/h (0,1 mR/h) (see NOTE). Account is
taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete NOTE 2.
Replaced
N
Bibliograph
y
Additional EN standards.
ZA
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR
CORRESPONDING EUROPEAN PUBLICATIONS
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
1.2.4.1
In Denmark, certain types of Class I appliances (see
3.2.1.1) may be provided with a plug not establishing
earthing conditions when inserted into Danish
socket-outlets.
N
1.2.13.14
(A11:2009)
In Norway and Sweden, for requirements see
1.7.2.1 and 7.3 of this annex.
N
1.5.7.1
(A11:2009)
In Finland, Norway and Sweden, resistors bridging
BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT
TYPE A must comply with the requirements in 1.5.7.1.
In addition when a single resistor is used, the
resistor must withstand the resistor test in 1.5.7.2.
N
Page 52 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
1.5.8
In Norway, due to the IT power system used (see
annex V, Figure V.7), capacitors are required to be
rated for the applicable line-to-line voltage (230 V).
N
1.5.9.4
In Finland, Norway and Sweden, the third dashed
sentence is applicable only to equipment as defined
in 6.1.2.2 of this annex.
N
1.7.2.1
In Finland, Norway and Sweden, CLASS I
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be
as follows:
In Finland: "Laite on liitettä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
N
1.7.2.1
(A11:2009)
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres en
galvanisk isolator mellom utstyret og kabel- TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
gguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV nät
kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”
N
Page 53 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
1.7.2.1
(A2:2013)
In Denmark, CLASS I PLUGGABLE EQUIPMENT
TYPE A intended for connection to other equipment
or a network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in Denmark shall be as follows:
In Denmark: “Apparatets stikprop skal tilsluttes en
stikkontakt med jord, som giver forbindelse til
stikproppens jord.”
N
1.7.5
1.7.5
(A11:2009)
In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when
used on Class I equipment. For STATIONARY
EQUIPMENT the socket-outlet shall be in
accordance with Standard Sheet DK 1-1b or DK 1-
5a.
For CLASS II EQUIPMENT the socket outlet shall be in
accordance with Standard Sheet DKA 1-4a.
N
1.7.5
(A2:2013)
In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the DS
60884-2-D1:2011.
For class I equipment the following Standard Sheets
are applicable: DK 1-3a, DK 1-1c,
DK 1-1d, DK 1-5a or DK 1-7a, with the exception for
STATIONARY EQUIPMENT where the socket-
outlets shall be in accordance with Standard Sheet
DK 1-1b, DK 1-1c, DK 1-1d or DK 1-5a.
Socket outlets intended for providing power to Class
II apparatus with a rated current of 2,5 A shall be in
accordance with DS 60884-2-D1 standard sheet
DKA 1-4a. Other current rating socket outlets shall
be in compliance with by DS 60884-2-D1
Standard Sheet DKA 1-3a or DKA 1-3b.
Justification
the Heavy Current Regulations, 6c
N
2.2.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and
6.1.2.2 of this annex.
N
2.3.2
In Finland, Norway and Sweden there are
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
N
2.3.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and
6.1.2.2 of this annex.
N
2.6.3.3
In the United Kingdom, the current rating of the
circuit shall be taken as 13 A, not 16 A.
N
Page 54 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
2.7.1
In the United Kingdom, to protect against excessive
currents and short-circuits in the PRIMARY CIRCUIT
of DIRECT PLUG-IN EQUIPMENT, tests according
to 5.3 shall be conducted, using an external
protective device rated 30 A or 32 A. If these tests
fail, suitable protective devices shall be included as
integral parts of the DIRECT PLUG-IN EQUIPMENT,
so that the requirements of 5.3 are met.
N
2.10.5.13
In Finland, Norway and Sweden, there are
additional requirements for the insulation, see
6.1.2.1 and 6.1.2.2 of this annex.
N
3.2.1.1
In Switzerland, supply cords of equipment having a
RATED CURRENT not exceeding 10 A shall be
provided with a plug complying with SEV 1011 or
IEC 60884-1 and one of the following dimension
sheets:
SEV 6532-2.1991 Plug Type 15 3P+N+PE
250/400 V, 10 A
SEV 6533-2.1991 Plug Type 11 L+N
250 V, 10 A
SEV 6534-2.1991 Plug Type 12 L+N+PE
250 V, 10 A
In general, EN 60309 applies for plugs for currents
exceeding 10 A. However, a 16 A plug and socket-
outlet system is being introduced in Switzerland, the
plugs of which are according to the following
dimension sheets, published in February 1998:
SEV 5932-2.1998: Plug Type 25 , 3L+N+PE 230/400
V, 16 A
SEV 5933-2.1998:Plug Type 21, L+N, 250 V, 16A
SEV 5934-2.1998: Plug Type 23, L+N+PE 250 V, 16
A
N
Page 55 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
3.2.1.1
In Denmark, supply cords of single-phase
equipment having a rated current not exceeding13 A
shall be provided with a plug according to the Heavy
Current Regulations, Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase equipment
having a RATED CURRENT exceeding 13 A is
provided with a supply cord with a plug, this plug
shall be in accordance with the Heavy Current
Regulations, Section 107-2-D1 or EN 60309-2.
N
3.2.1.1
(A2:2013)
In Denmark, supply cords of single-phase
equipment having a rated current not exceeding 13 A
shall be provided with a plug according to DS 60884-
2-D1.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a poly-phase
equipment is provided with a supply cord with a plug,
this plug shall be in accordance with the standard
sheets DK 6-1a in DS 60884-2-D1 or EN 60309-2.
Justification
the Heavy Current Regulations, 6c
N
3.2.1.1
In Spain, supply cords of single-phase equipment
having a rated current not exceeding 10 A shall be
provided with a plug according to UNE 20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be provided
with a plug according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules, shall be
provided with a plug in accordance with standard
UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance with
UNE-EN 60309-2.
The plug cord set was
approved
P
Page 56 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
3.2.1.1
In the United Kingdom, apparatus which is fitted
with a flexible cable or cord and is designed to be
connected to a mains socket conforming to BS 1363
by means of that flexible cable or cord and plug,
shall be fitted with a „standard plug‟ in accordance
with Statutory Instrument 1768:1994 - The Plugs and
Sockets etc. (Safety) Regulations 1994, unless
exempted by those regulations.
NOTE „Standard plug‟ is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS
1363 or an approved conversion plug.
N
3.2.1.1
In Ireland, apparatus which is fitted with a flexible
cable or cord and is designed to be connected to a
mains socket conforming to I.S. 411 by means of
that flexible cable or cord and plug, shall be fitted
with a 13 A plug in accordance with Statutory
Instrument 525:1997 - National Standards Authority
of Ireland (section 28) (13 A Plugs and Conversion
Adaptors for Domestic Use) Regulations 1997.
N
3.2.4
In Switzerland, for requirements see 3.2.1.1 of this
annex.
N
3.2.5.1
In the United Kingdom, a power supply cord with
conductor of 1,25 mm2 is allowed for equipment with
a rated current over 10 A and up to and including 13
A.
N
3.3.4
In the United Kingdom, the range of conductor
sizes of flexible cords to be accepted by terminals for
equipment with a RATED CURRENT of over 10 A up
to and including 13 A is:
• 1,25 mm2 to 1,5 mm2 nominal cross-sectional area.
N
4.3.6
In the United Kingdom, the torque test is performed
using a socket outlet complying with BS 1363 part
1:1995, including Amendment 1:1997 and
Amendment 2:2003 and the plug part of DIRECT
PLUG-IN EQUIPMENT shall be assessed to BS
1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12,
12.13, 12.16 and 12.17, except that the test of 12.17
is performed at not less than 125 °C. Where the
metal earth pin is replaced by an Insulated Shutter
Opening Device (ISOD), the requirements of clauses
22.2 and 23 also apply.
P
4.3.6
In Ireland, DIRECT PLUG-IN EQUIPMENT is known
as plug similar devices. Such devices shall comply
with Statutory Instrument 526:1997 - National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and sockets for
domestic use) Regulations, 1997.
N
Page 57 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
5.1.7.1
In Finland, Norway and Sweden TOUCH
CURRENT measurement results exceeding 3,5 mA
r.m.s. are permitted only for the following equipment:
• STATIONARY PLUGGABLE EQUIPMENT TYPE A
that
is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential bonding
has been applied, for example, in a
telecommunication centre; and
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
is provided with instructions for the installation
of that conductor by a SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT TYPE
B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
N
6.1.2.1
(A1:2010)
In Finland, Norway and Sweden, add the following
text between the first and second paragraph of the
compliance clause:
If this insulation is solid, including insulation forming
part of a component, it shall at least consist of either
- two layers of thin sheet material, each of
which shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and in
addition
- passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.
N
Page 58 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to EN
60384-14:2005, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
60384-14, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in EN
60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in EN
60384-14:
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 60384-14, in
the sequence of tests as described in EN 60384-14.
N
6.1.2.2
In Finland, Norway and Sweden, the exclusions are
applicable for PERMANENTLY CONNECTED
EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B
and equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has provision
for a permanently connected PROTECTIVE
EARTHING CONDUCTOR and is provided with
instructions for the installation of that conductor by a
SERVICE PERSON.
N
7.2
In Finland, Norway and Sweden, for requirements
see 6.1.2.1 and 6.1.2.2 of this annex.
The term TELECOMMUNICATION NETWORK in
6.1.2 being replaced by the term CABLE
DISTRIBUTION SYSTEM.
N
7.3
(A11:2009)
In Norway and Sweden, for requirements see
1.2.13.14 and 1.7.2.1 of this annex.
N
Page 59 of 59 Report No.: DE115902
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B_M2 STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Annex ZD
(informative)
IEC and CENELEC code designations for flexible cords
Type of flexible cord
Code designations
IEC
CENELEC
PVC insulated cords
Flat twin tinsel cord
60227 IEC 41
H03VH-Y
Light polyvinyl chloride sheathed flexible cord
60227 IEC 52
H03VV-F
H03VVH2-F
Ordinary polyvinyl chloride sheathed flexible cord
60277 IEC 53
H05VV-F
H05VVH2-F
Rubber insulated cords
Braided cord
60245 IEC 51
H03RT-F
Ordinary tough rubber sheathed flexible cord
60245 IEC 53
H05RR-F
Ordinary polychloroprene sheathed flexible cord
60245 IEC 57
H05RN-F
Heavy polychloroprene sheathed flexible cord
60245 IEC 66
H07RN-F
Cords having high flexibility
Rubber insulated and sheathed cord
60245 IEC 86
H03RR-H
Rubber insulated, crosslinked PVC sheathed cord
60245 IEC 87
H03RV4-H
Crosslinked PVC insulated and sheathed cord
60245 IEC 88
H03V4V4-H
 End of Test Report 
Appendix Page 1 of 5 Report No.: DE115902
STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Product Photographs
Appendix Page 2 of 5 Report No.: DE115902
STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Product Photographs
Appendix Page 3 of 5 Report No.: DE115902
STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Product Photographs
Appendix Page 4 of 5 Report No.: DE115902
STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Product Photographs
Appendix Page 5 of 5 Report No.: DE115902
STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org
Product Photographs