561419 IEC 60950 1
2019-01-16
: Pdf 561419-Iec-60950-1 561419-IEC-60950-1 CertsReports 561419 ProductFiles
Open the PDF directly: View PDF .
Page Count: 84
Download | |
Open PDF In Browser | View PDF |
AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Report No.: ACSS1811066 Page 2 of 83 Copy of marking plate (Remark: Above label stuck on the outside of enclosure) Note(s): - The marking plate(s) artwork appended to this report may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks.) - The height of CE symbol should be 5.0 mm Min. Summary of testing: Following symbols and abbreviations may be used in this test report. F= Function Insulation B= Basic Insulation S= Supplementary Insulation D/R= Double or Reinforced Insulation S/C= Short-Circuit O/C= Open-Circuit O/L= Over-Load B/L= Block IP= Internal protection operated (list component) CT= Constant temperatures were obtained CD= Components damaged (list damaged components) NB= No indication of dielectric breakdown NC= Cheesecloth remained intact NT= Tissue paper remained intact NH= No hazard occured Pri.= Primary Sec.= Secondary PCB= Printed Circuit Board PSU= Power Supply Unit EUT= Equipment Under Test EPS= External Power Supply TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 3 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Test item particulars: Equipment mobility………........................................ …: [x] movable [] hand-held [] transportable [] stationary [] for building-in [] direct plug-in [] rack-mounted Connection to the mains ………………………..………: [x] pluggable equipment: [x] type A [] type B [] permanent connection [x] detachable power supply cord [] non-detachable power supply cord [] not directly connected to the mains Operation condition …………………………………..…: [x] continuous [] rated operating / resting time: Access location ......................................................... : [x] operator accessible [] restricted access location Over voltage category (OVC) ................................... : [] OVC I [] other: Mains supply tolerance (%) or absolute mains supply values ........................................................................ : +10%, -10% [x] OVC II Tested for IT power systems .................................... : [] Yes IT testing, phase-phase voltage (V) .......................... : N/A Class of equipment ................................................... : [x] Class I [] Class II [] Not classified Pollution degree (PD) ............................................... : [] PD 1 IP protection class .................................................... : IPX0 Altitude during operation (m) .................................... : Up to 2000m Altitude of test laboratory (m) .................................... : Up to 2000m Mass of equipment (kg) ………………………………..: 3.4kg Maximum operation ambient …………………...……..: 50C [] OVC III [] OVC IV [x] No [x] PD 2 [] Class III [] PD 3 Possible test case verdicts: - Test case does not apply to the test object ………….: N (Not Applicable) - Test object does meet the requirement………………: P (Pass) - Test object does not meet the requirement………….: F (Fail) Testing: Date of receipt of test item……………………………...: N/A Date of receipt of test sample ....................................... : N/A Status of test sample .................................................... : N/A Date(s) of performance of tests ………………………..: N/A General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Attachment #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report, a point is used as the decimal separator. List of test equipment must be kept on file and available for review. TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 4 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD General product information: 1. The EUT is a 16-Port Gigabit Ethernet PoE+ Switch with 4 RJ45 Gigabit and 2 SFP Uplink Ports. 2. This amendment report shall be read in conjunction with original test report (ACSS1703016). 3. The updates concerned in this test report are as follows: 1). Revise applicant’s company name and address; 2). Revise manufacturer’s company name and address; 3). Revise product’s name and model; 4). The RJ45 ports 1-20 must be available, 21-24 can be optional. 4. After technical review, no test is necessary. All the test data were fully reproduced from original report (ACSS1703016). Report modify history Report No. / issue date No. 1 ACSS1703016/ April 6, 2017 Modification to the appliances: Original test report Additional information: N/A Attached enclosure(s): Attachment A: 5 pages of Photo-Documentation. Attachment B: 6 pages of Heatsink-Drawing. Attachment C: 3 pages of Schematic and layout for power board. Attachment D: 2 pages of Transformer T1 specification. Attachment E: 2 pages of Transformer T2 specification. TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 5 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 1 GENERAL P 1.5 Components P 1.5.1 General P Comply with IEC 60950-1 or relevant component standard (See appended table 1.5.1) P 1.5.2 Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this standard. Components not certified are used in accordance with their ratings and they comply with applicable parts of IEC 609501 and the relevant component standard. Components, for which no relevant IEC-standard exists, have been tested under the conditions occurring in the equipment, using applicable parts of IEC 60950-1. P 1.5.3 Thermal controls Thermal controller (TH5) meet the standard EN 60730-1. P 1.5.4 Transformers Comply with annex C P 1.5.5 Interconnecting cables Interconnection cables do not present a hazard. P 1.5.6 Capacitors bridging insulation X2 capacitors and Y1 capacitors are used to be according to IEC 60384-14. P 1.5.7 Resistors bridging insulation Refer to below: P 1.5.7.1 Resistors bridging functional, basic or supplementary Bleeder resistors are bridging insulation function insulation. P 1.5.7.2 Resistors bridging double or reinforced insulation between a.c. mains and other circuits N 1.5.7.3 Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable N 1.5.8 Components in equipment for IT power systems N 1.5.9 Surge suppressors Approved surge suppressors. P 1.5.9.1 General Comply with annex Q P 1.5.9.2 Protection of VDRs A fuse is connected in series with VDR. P 1.5.9.3 Bridging of functional insulation by a VDR Varistor(ZR1) located in line to neutral after fuse(F1) P TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 6 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test 1.5.9.4 Bridging of basic insulation by a VDR N 1.5.9.5 Bridging of supplementary, double or reinforced insulation by a VDR N 1.6 Power interface P 1.6.1 AC power distribution systems TN power systems. P 1.6.2 Input current (See appended table 1.6.2) P 1.6.3 Voltage limit of hand-held equipment This appliance is not handheld equipment. N 1.6.4 Neutral conductor P 1.7 Marking and instructions P 1.7.1 Power rating P Rated voltage(s) or voltage range(s) (V) ................. : Result - Remark 100-240V Symbol for nature of supply, for d.c. only .............. : Verdict P N Rated frequency or rated frequency range (Hz) ... : 50/60Hz P Rated current (mA or A) ........................................ : 5A max P Manufacturer’s name or trade-mark or identification mark ...................................................................... : P Model identification or type reference ................... : 561419 P Symbol for Class II equipment only ......................... : Class I equipment. N Other markings and symbols ................................... : Other symbols do not affect safety. P 1.7.2 Safety instructions and marking Refer to below: P 1.7.2.1 General 1.7.2.2 Disconnect devices Appliance inlet provided. N 1.7.2.3 Overcurrent protective device The unit is not pluggable equipment type B or permanently connected equipment. N 1.7.2.4 IT power distribution systems 1.7.2.5 Operator access with a tool All areas containing hazard(s) are inaccessible to the operator. N 1.7.2.6 Ozone The equipment not containing Ozone N 1.7.3 Short duty cycles The equipment is intended for continuous operation. N 1.7.4 Supply voltage adjustment ................................... : No voltage selector. N Methods and means of adjustment; reference to installation instructions ......................................... : TRF No. SRENAV-01V1.4 P N N Report No.: ACSS1811066 Page 7 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 1.7.5 Power outlets on the equipment .......................... : No standard power outlet. N 1.7.6 Fuse identification (marking, special fusing characteristics, cross-reference) .......................... : “T8AL/250V” near F1 P 1.7.7 Wiring terminals Refer to below P 1.7.7.1 Protective earthing and bonding terminals .......... : Appliance inlet was used P 1.7.7.2 Terminals for a.c. mains supply conductors The equipment power connection is detachable power supply cord. N 1.7.7.3 Terminals for d.c. mains supply conductors 1.7.8 Controls and indicators See below: P 1.7.8.1 Identification, location and marking ..................... : The function of indicators affecting safety is obvious without knowledge of language. P 1.7.8.2 Colours ................................................................ : Colors are used for functional indications, not involved safety. P 1.7.8.3 Symbols according to IEC 60417 ........................ : 1.7.8.4 Markings using figures ....................................... : No controls use figures. N 1.7.9 Isolation of multiple power sources .................... : Only one connection supplying hazardous voltages and energy levels to the equipment. N 1.7.10 Thermostats and other regulating devices ......... : No thermostats or other regulating devices. N 1.7.11 Durability The marking withstands required tests. P 1.7.12 Removable parts No removable parts. N 1.7.13 Replaceable batteries ......................................... : No battery in the equipment. N N N Language(s) .........................................................: — Equipment for restricted access locations ........... : 2 PROTECTION FROM HAZARDS P 2.1 Protection from electric shock and energy hazards P 2.1.1 Protection in operator access areas 2.1.1.1 Access to energized parts Test by inspection .................................................... : TRF No. SRENAV-01V1.4 Equipment not intended for installation in RAL. N 1.7.14 No operator access to energized parts. P P Operator access areas are protected from electric shock and energy hazards P Report No.: ACSS1811066 Page 8 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Test with test finger (Figure 2A) ............................ : Not touched to hazardous parts P Test with test pin (Figure 2B) ................................ : Not touched to hazardous parts P Test with test probe (Figure 2C) ........................... : No TNV circuits in the equipment. N 2.1.1.2 Battery compartments No battery compartments. N 2.1.1.3 Access to ELV wiring No internal wiring at ELV accessible to the operator. N Working voltage (Vpeak or Vrms); minimum distance through insulation (mm) Verdict — 2.1.1.4 Access to hazardous voltage circuit wiring No hazardous voltage wiring in operator accessible area. P 2.1.1.5 Energy hazards ........................................................ : (see appended table 2.1.1.5) P 2.1.1.6 Manual controls No shafts of knobs etc. N 2.1.1.7 Discharge of capacitors in equipment Measured voltage (V); time-constant (s) .................. : 2.1.1.8 P (see appended table 2.1.1.7) — Energy hazards – d.c. mains supply N a) Capacitor connected to the d.c. mains supply .... : N b) Internal battery connected to the d.c. mains supply ................................................................................... : N 2.1.1.9 Audio amplifiers ........................................................ : N 2.1.2 Protection in service access areas No unexpected hazards inside the unit and no unintentional contact to hazardous areas likely during service operations as considering the equipment disconnected from mains when servicing. P 2.1.3 Protection in restricted access locations Equipment not intended for installation in RAL. N 2.2 SELV circuits P 2.2.1 General requirements P 2.2.2 Voltages under normal conditions (V) .................. : (see appended table 2.2.2) P 2.2.3 Voltages under fault conditions (V) ....................... : (see appended table 2.2.3) P 2.2.4 Connection of SELV circuits to other circuits ...... : Connected to other SELV circuits. P 2.3 TNV circuits No TNV circuit. N 2.3.1 Limits N TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 9 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Type of TNV circuits .................................................. : — 2.3.2 Separation from other circuits and from accessible parts N 2.3.2.1 General requirements N 2.3.2.2 Protection by basic insulation N 2.3.2.3 Protection by earthing N 2.3.2.4 Protection by other constructions ......................... : N 2.3.3 Separation from hazardous voltages N Insulation employed ............................................... : — Connection of TNV circuits to other circuits N Insulation employed ............................................... : — 2.3.5 Test for operating voltages generated externally N 2.4 Limited current circuits P 2.4.1 General requirements P 2.4.2 Limit values 2.3.4 (see appended table 2.4) P Frequency (Hz).......................................................... : — Measured current (mA) ............................................. : — Measured voltage (V) ................................................ : — Measured circuit capacitance (nF or µF) ............... : — 2.4.3 Connection of limited current circuits to other circuits 2.5 Limited power sources a) Inherently limited output Connected to SELV P (see appended table 2.5) b) Impedance limited output c) Regulating network limited output under normal operating and single fault condition P N (see appended table 2.5) d) Overcurrent protective device limited output Max. output voltage (V), max. output current (A), max. apparent power (VA) ..................................... : P P N (see appended table 2.5) — Current rating of overcurrent protective device (A) .: — 2.6 Provisions for earthing and bonding P 2.6.1 Protective earthing TRF No. SRENAV-01V1.4 Accessible conductive parts are reliably connected to protective earth. P Report No.: ACSS1811066 Page 10 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark 2.6.2 Functional earthing Secondary functional earthing is separated to primary by reinforced or double insulation. P 2.6.3 Protective earthing and protective bonding conductors See below P 2.6.3.1 General 2.6.3.2 Size of protective earthing conductors P Power supply cord was not provided 2 Rated current (A), cross-sectional area (mm ), AWG ...................................................................... : 2.6.3.3 Verdict — Protective bonding conductor which connects to inlet ground pin. See cl. 2.6.3.4 for ground continue test. Size of protective bonding conductors N 2 P Rated current (A), cross-sectional area (mm ), AWG ...................................................................... : — Protective current rating (A), cross-sectional area 2 (mm ), AWG ........................................................... : — 2.6.3.4 Resistance of earthing conductors and their terminations; resistance (), voltage drop (V), test current (A), duration (min) ......................................... : 2.6.3.5 Colour of insulation.................................................... : 2.6.4 Terminals 2.6.4.1 General 2.6.4.2 Protective earthing and bonding terminals The earthing terminal in the appliance inlet is regarded as the main protective earthing terminal. The test of subclause 2.6.3.4 was performed for protective bonding conductor and their terminals. P Rated current (A), type, nominal thread diameter (mm)........................................................................... : The test of cl. 2.6.3.4 is complied. 2.6.4.3 Separation of the protective earthing conductor from protective bonding conductors The equipment is provided with an appliance inlet. P 2.6.5 Integrity of protective earthing See below P 2.6.5.1 Interconnection of equipment No interconnection of equipment. N 2.6.5.2 Components in protective earthing conductors and protective bonding conductors There are no switches or overcurrent protective devices in the protective earthing / bonding conductor. P TRF No. SRENAV-01V1.4 (See appended table 2.6.3.4) P N See below P P Report No.: ACSS1811066 Page 11 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark 2.6.5.3 Disconnection of protective earth It is not possible to disconnect protective earth without disconnecting mains; an appliance coupler will be used as disconnect device. P 2.6.5.4 Parts that can be removed by an operator Appliance couplers provided for the protective earthing connection is made before and broken after the hazardous voltage. No other operator removable parts. P 2.6.5.5 Parts removed during servicing Protective earthed parts cannot be removed in a way which impair safety. P 2.6.5.6 Corrosion resistance No risk of corrosion P 2.6.5.7 Screws for protective bonding Adequate connection of protective bonding. P 2.6.5.8 Reliance on telecommunication network or cable distribution system Neither TNV circuits nor cable distribution system in the equipment. N 2.7 Overcurrent and earth fault protection in primary circuits P 2.7.1 Basic requirements P Pluggable equipment type A primary fuse is used for protective device. Instructions when protection relies on building installation Verdict N 2.7.2 Faults not simulated in 5.3.7 Considered P 2.7.3 Short-circuit backup protection The building installation is considered as providing shortcircuit backup protection. P 2.7.4 Number and location of protective devices .............: Number: 1 Location: line P 2.7.5 Protection by several devices N 2.7.6 Warning to service personnel ...................................: 2.8 Safety interlocks No safety interlocks provided. N 2.8.1 General principles N 2.8.2 Protection requirements N 2.8.3 Inadvertent reactivation N 2.8.4 Fail-safe operation N 2.8.5 Moving parts N TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 12 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 2.8.6 Overriding N 2.8.7 Switches, relays and their related circuits N 2.8.7.1 Separation distances for contact gaps and their related circuits (mm) ........................................... : 2.8.7.2 Overload test N 2.8.7.3 Endurance test N 2.8.7.4 Electric strength test N 2.8.8 Mechanical actuators N 2.9 Electrical insulation P 2.9.1 Properties of insulating materials Neither natural rubber, materials containing asbestos or hygroscopic materials are used as insulation. No driving belts or couplings used. P 2.9.2 Humidity conditioning 120Hours P Relative humidity (%), temperature (°C) ............... : 96% RH, 40 degree C. — 2.9.3 Grade of insulation Refer to cl.2.10 and appended table 5.2 P 2.9.4 Separation from hazardous voltages For metal enclosure, basic insulation used; For output terminals, double or reinforced insulation used. P Method(s) used ..................................................... : Method 1and method 2 — 2.10 Clearances, creepage distances and distances through insulation P 2.10.1 General P 2.10.1.1 Frequency .............................................................. : Considered — 2.10.1.2 Pollution degrees ................................................... : 2 — 2.10.1.3 Reduced values for functional insualtion The function insulation complied with clause 5.3.4C P 2.10.1.4 Intervening unconnected conductive parts P 2.10.1.5 Insulation with varying dimensions N 2.10.1.6 Special separation requirements N 2.10.1.7 Insulation in circuits generating starting pulses N 2.10.2 Determination of working voltage 2.10.2.1 General 2.10.2.2 RMS working voltage See appended table 2.10.2 P 2.10.2.3 Peak working voltage See appended table 2.10.2 P TRF No. SRENAV-01V1.4 See appended table 2.10.2 P P Report No.: ACSS1811066 Page 13 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 2.10.3 Clearances 2.10.3.1 General Refer to below P 2.10.3.2 Mains transient voltages Considered P a) AC mains supply ............................................... : Over voltage category II for primary circuit and transient voltage 2500Vpeak. — P b) Earthed d.c. mains supplies .............................. : — c) Unearthed d.c. mains supplies .......................... : — d) Battery operation ............................................... : — 2.10.3.3 Clearances in primary circuits See appended table 2.10.3 and 2.10.4 P 2.10.3.4 Clearances in secondary circuits Function insulation, meet 5.3.4 method c). P 2.10.3.5 Clearances in circuits having starting pulses The circuit will not generate starting pulse. N 2.10.3.6 Transients from a.c. mains supply ........................ : — 2.10.3.7 Transients from d.c. mains supply ........................ : — 2.10.3.8 Transients from telecommunication networks and cable distribution systems ..................................... : — 2.10.3.9 Measurement of transient voltage levels N a) Transients from a mains suplply N For an a.c. mains supply ....................................... : — For a d.c. mains supply ......................................... : — b) Transients from a telecommunication network : N 2.10.4 Creepage distances P 2.10.4.1 General Refer to below: P 2.10.4.2 Material group and comparative tracking index Material group IIIb is assumed. P CTI tests .................................................................... : — 2.10.4.3 Minimum creepage distances 2.10.5 Solid insulation P 2.10.5.1 General P 2.10.5.2 Distances through insulation See appended table 2.10.5 P 2.10.5.3 Insulating compound as solid insulation See appended table 1.5.1 P 2.10.5.4 Semiconductor devices See appended table 1.5.1 P 2.10.5.5 Cemented joints N 2.10.5.6 Thin sheet material – General P TRF No. SRENAV-01V1.4 See appended table 2.10.3 and 2.10.4 P Report No.: ACSS1811066 Page 14 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 2.10.5.7 Separable thin sheet material Insulation tape used wrapped on the transformer. P Number of layers (pcs) ........................................... : 2 layers as reinforced insulation. — 2.10.5.8 Non-separable thin sheet material N 2.10.5.9 Thin sheet material – standard test procedure N Electric strength test — Thin sheet material – alternative test procedure P 2.10.5.10 Electric strength test 2.10.5.11 Insulation in wound components 2.10.5.12 Wire in wound components See appended table 5.2 N Primary winding on the transformer T2 in power board was used triple insulated wire. — a) Basic insulation not under stress ...................... : — Wire complies to Annex U, three layers as reinforced insulation. c) Compliance with Annex U ................................. : Two wires in contact inside wound component; angle between 45 and 90 ................................... : 2.10.5.14 P Working voltage ..................................................... : b) Basic, supplemetary, reinforced insulation ....... : 2.10.5.13 — — — Protection against mechanical stress is provided by tube and insulation tape. — Wire with solvent-based enamel in wound components N Electric strength test — Routine test N Additional insulation in wound components N Working voltage ..................................................... : — - Basic insulation not under stress ........................ : — - Supplemetary, reinforced insulation .................... : — 2.10.6 Construction of printed boards Refer to below: P 2.10.6.1 Uncoated printed boards (See appended table 2.10.3 and 2.10.4) P 2.10.6.2 Coated printed boards N 2.10.6.3 Insulation between conductors on the same inner surface of a printed board N 2.10.6.4 Insulation between conductors on different layers of Refer to below a printed board P Distance through insulation P TRF No. SRENAV-01V1.4 1.6mm Report No.: ACSS1811066 Page 15 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Number of insulation layers (pcs)............................. : 1 — 2.10.7 Component external terminations (See appended table 2.10.3 and 2.10.4) P 2.10.8 Tests on coated printed boards and coated components N 2.10.8.1 Sample preparation and preliminary inspection N 2.10.8.2 Thermal conditioning N 2.10.8.3 Electric strength test N 2.10.8.4 Abrasion resistance test N 2.10.9 Thermal cycling 2.10.10 Test for Pollution Degree 1 environment and insulating compound N 2.10.11 Tests for semiconductor devices and cemented joints Optical isolators approved See appended table 1.5.1 P 2.10.12 Enclosed and sealed parts N 3 WIRING, CONNECTIONS AND SUPPLY P 3.1 General P 3.1.1 Current rating and overcurrent protection Adequate cross sectional areas on internal wiring. P 3.1.2 Protection against mechanical damage Wireways are smooth and free from edges. Wires are adequetely fixed to present excessive strain on wire and terminals and avoiding damage to the insulation of the conductors. P 3.1.3 Securing of internal wiring Wireways are smooth and free from edges. Wires are adequately fixed to prevent excessive strain on wire and terminals and avoiding damage to the insulation of the conductors. P 3.1.4 Insulation of conductors Insulation on terminal conductors is considered to be of adequate quality and suitable for the application and the working voltage involved. P 3.1.5 Beads and ceramic insulators Not provided. N 3.1.6 Screws for electrical contact pressure At least two complete threads into the metal plate. P TRF No. SRENAV-01V1.4 Optical isolators approved See appended table 1.5.1 Verdict P Report No.: ACSS1811066 Page 16 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 3.1.7 Insulating materials in electrical connections All connections are metal to metal, or where contact pressure is transmitted through PCB material for earthing purposes a combination of screw. P 3.1.8 Self-tapping and spaced thread screws Not use self-tapping and spaced thread screws N 3.1.9 Termination of conductors Terminations cannot become displaced so that clearances and creepage distances can be reduced. P 10 N pull test Considered P 3.1.10 Sleeving on wiring Sleeving could not slip P 3.2 Connection to a mains supply 3.2.1 Means of connection 3.2.1.1 Connection to an a.c. mains supply 3.2.1.2 Connection to a d.c. mains supply The equipment is not for connection to a d.c. mains supply. N 3.2.2 Multiple supply connections Single phase supply. N 3.2.3 Permanently connected equipment Not permanently connected equipment. N P Appliance inlet P P Number of conductors, diameter of cable and conduits (mm) ........................................................: 3.2.4 Appliance inlets The appliance inlet complies with IEC 60320-1 and is properly placed to avoid hazards after insertion of the appliance coupler. P 3.2.5 Power supply cords No power cord provided. N 3.2.5.1 AC power supply cords N Type .......................................................................: — 2 Rated current (A), cross-sectional area (mm ), AWG ......................................................................: — 3.2.5.2 DC power supply cords Not connected to DC supply. N 3.2.6 Cord anchorages and strain relief Equipment provided with an appliance inlet. N Mass of equipment (kg), pull (N) ..........................: — Longitudinal displacement (mm) ...........................: 3.2.7 Protection against mechanical damage TRF No. SRENAV-01V1.4 No sharp points of cutting edges on the equipment surfaces. — P Report No.: ACSS1811066 Page 17 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test 3.2.8 Cord guards N Diameter or minor dimension D (mm); test mass (g) ................................................................................: — Radius of curvature of cord (mm) ...........................: — 3.2.9 Supply wiring space N 3.3 Wiring terminals for connection of external conductors N 3.3.1 Wiring terminals N 3.3.2 Connection of non-detachable power supply cords N 3.3.3 Screw terminals N 3.3.4 Conductor sizes to be connected N Rated current (A), cord/cable type, cross-sectional 2 area (mm ) ..............................................................: — Wiring terminal sizes N Rated current (A), type, nominal thread diameter (mm) ......................................................................: — 3.3.6 Wiring terminal design N 3.3.7 Grouping of wiring terminals N 3.3.8 Stranded wire N 3.4 Disconnection from the mains supply P 3.4.1 General requirement P 3.4.2 Disconnect devices 3.4.3 Permanently connected equipment N 3.4.4 Parts which remain energized N 3.4.5 Switches in flexible cords No such switches used. N 3.4.6 Number of poles - single-phase and d.c. equipment Disconnect device disconnects all poles simultaneously. P 3.4.7 Number of poles - three-phase equipment Single phase equipment. N 3.4.8 Switches as disconnect devices No such switches used. N 3.4.9 Plugs as disconnect devices The appliance coupler will be regarded as disconnect device, no warning is required. N 3.4.10 Interconnected equipment No interconnection of hazardous voltages or energy levels. N 3.4.11 Multiple power sources One power source only. N 3.3.5 TRF No. SRENAV-01V1.4 Result - Remark No wiring terminals. Appliance coupler Verdict P Report No.: ACSS1811066 Page 18 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 3.5 Interconnection of equipment 3.5.1 General requirements Considered. P 3.5.2 Types of interconnection circuits ............................. : SELV circuits. P 3.5.3 ELV circuits as interconnection circuits No ELV interconnection. N 3.5.4 Data ports for additional equipment (see appended table 2.5) P 4 PHYSICAL REQUIREMENTS P 4.1 Stability N P Angle of 10 ≤7kg N Test force (N) ........................................................ : The unit is not floor-standing. — 4.2 Mechanical strength P 4.2.1 General P 4.2.2 Steady force test, 10 N 4.2.3 Steady force test, 30 N 4.2.4 Steady force test, 250 N No hazard. The test is performed at top, bottom and sides of metal enclosure. P 4.2.5 Impact test Carried out to top side, lateral-sides and bottom side of Enclosure. P Fall test No hazard as result of the impact test. P No hazard as a result of the 10N test. P N Swing test N 4.2.6 Drop test; height (mm) .......................................... : N 4.2.7 Stress relief test Metal enclosure. N 4.2.8 Cathode ray tubes No CRT provided. N Picture tube separately certified ........................... : N 4.2.9 High pressure lamps 4.2.10 Wall or ceiling mounted equipment; force (N) ....... : N 4.2.11 Rotating solid media N Test to cover on the door………………………….: — 4.3 Design and construction P 4.3.1 Edges and corners TRF No. SRENAV-01V1.4 No high pressure lamp provided. All edges and corners are rounded and/or smoothed. N P Report No.: ACSS1811066 Page 19 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 4.3.2 Handles and manual controls; force (N) ............. : No knobs, grips, handles, lever etc. N 4.3.3 Adjustable controls No hazardous adjustable controls. N 4.3.4 Securing of parts All hazardous parts are fixed to retain position in event of termination failure. P 4.3.5 Connection by plugs and sockets SELV connector does not comply with IEC 60320 or IEC 60083. P 4.3.6 Direct plug-in equipment Not direct plug-in equipment. N Torque .................................................................. : — Compliance with the relevant mains plug standard .............................................................................. : N 4.3.7 Heating elements in earthed equipment No heating elements provided. N 4.3.8 Batteries N - Overcharging of a rechargeable battery N - Unintentional charging of a non-rechargeable battery N - Reverse charging of a rechargeable battery N - Excessive discharging rate for any battery N 4.3.9 Oil and grease Insulation is not exposed to oil, grease etc. N 4.3.10 Dust, powders, liquids and gases The equipment does not contain flammable liquids or gases. N 4.3.11 Containers for liquids or gases No containers for liquids or gases in the equipment. N 4.3.12 Flammable liquids ................................................ : The equipment does not contain flammable liquid. N Quantity of liquid (l) .............................................. : N Flash point (C) .................................................... : N 4.3.13 Radiation 4.3.13.1 General 4.3.13.2 Ionizing radiation See below P P The equipment does not generate ionizing radiation. N Measured radiation (pA/kg) .................................. : — Measured high-voltage (kV) ................................. : — Measured focus voltage (kV) ............................... : — CRT markings ...................................................... : — TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 20 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause 4.3.13.3 Requirement + Test Result - Remark Effect of ultraviolet (UV) radiation on materials The equipment does not produce significant UV radiation. Part, property, retention after test, flammability classification ......................................................... : Verdict N N 4.3.13.4 Human exposure to ultraviolet (UV) radiation ...... : The equipment does not produce significant UV radiation. N 4.3.13.5 Lasers (including laser diodes) and LEDs P 4.3.13.5.1 Lasers (including laser laser diodes) N Laser class ........................................................... : 4.3.13.5.2 Light emitting diodes (LEDs) Diffusive LED only, the energy of the indicator LED is far below the limit for class I LED products. P 4.3.13.6 Other types .......................................................... : The equipment does not generate other types of radiation. N 4.4 Protection against hazardous moving parts 4.4.1 General Approved DC fan. P 4.4.2 Protection in operator access areas .................... : P 4.4.3 Protection in restricted access locations .............. : No possible to access the DC fan blades through the openings on right cover. No such locations. 4.4.4 Protection in service access areas 4.4.5 Protection against moving fan blades See below P 4.4.5.1 General m=0.008kg, r=20mm, N=5500r/min Complied. (See appended table 4.4.5) P 4.4.5.3 N N Not considered to cause pain or injury. a)………….: 4.4.5.2 P Is considered to cause pain, not injury. b) …………: Considered to cause injury. c) …………: Protection for users N Use of symbol or warning ……………………...……: Protection for service persons N Use of symbol or warning ………………...…………: 4.5 Thermal requirements P 4.5.1 General P 4.5.2 Temperature tests (See appended table 4.5.2) Normal load condition per Annex L .........................: 4.5.3 Temperature limits for materials TRF No. SRENAV-01V1.4 P — Not exceed the values. P Report No.: ACSS1811066 Page 21 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark 4.5.4 Touch temperature limits Not exceed the values. P 4.5.5 Resistance to abnormal heat ............................... : Complying. (See appended table 1.5.1) P 4.6 Openings in enclosures P 4.6.1 Top and side openings P 4.6.2 Verdict Dimensions (mm) ................................................. : See appended table 4.6.1,4.6.2 — Bottoms of fire enclosures No opening P Construction of the bottomm, dimensions (mm) ....: — 4.6.3 Doors or covers in fire enclosures N 4.6.4 Openings in transportable equipment 4.6.4.1 Constructional design measures N Dimensions (mm) ....................................................: — 4.6.4.2 Evaluation measures for larger openings N 4.6.4.3 Use of metallized parts N 4.6.5 Adhesives for constructional purposes Not transportable equipment Adhesives not used. N N Conditioning temperature (C), time (weeks)........ : — 4.7 Resistance to fire P 4.7.1 Reducing the risk of ignition and spread of flame In accordance with method 1. P Method 1, selection and application of components wiring and materials Materials with the required flammability classes are used. P Method 2, application of all of simulated fault condition tests Method 1 used. N 4.7.2 Conditions for a fire enclosure Refer to below: P 4.7.2.1 Parts requiring a fire enclosure The fire enclosure is required to cover all parts. P 4.7.2.2 Parts not requiring a fire enclosure The fire enclosure is required to cover all parts. N 4.7.3 Materials Refer to below: P 4.7.3.1 General Components and material have adequate flammability classification. (See appended table 1.5.1) P 4.7.3.2 Materials for fire enclosures Metallic P 4.7.3.3 Materials for components and other parts outside fire enclosures Fire enclosures cover all parts N TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 22 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 4.7.3.4 Materials for components and other parts inside fire enclosures Internal components and other parts inside fire enclosure are rated min. V-2. P 4.7.3.5 Materials for air filter assemblies No air filters in the equipment. N 4.7.3.6 Materials used in high-voltage components No high-voltage components. N 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS P 5.1 Touch current and protective conductor current P 5.1.1 General Test conducted in accordance with cl.5.1.2 to cl.5.1.7 P 5.1.2 Configuration of equipment under test (EUT) No interconnected equipment or multiple power sources N 5.1.2.1 Single connection to an a.c. mains supply P 5.1.2.2 Redundant multiple connections to an a.c. mains supply N 5.1.2.3 Simultaneous multiple connections to an a.c. mains supply N 5.1.3 Test circuit Figure 5A used P 5.1.4 Application of measuring instrument Measuring circuit in annex D.1 used P 5.1.5 Test procedure 5.1.6 Test measurements See below P Supply voltage (V) ................................................ : 264Vac, 60Hz — Measured touch current (mA) .............................. : See appended table 5.1.6 — Max. allowed touch current (mA) ......................... : Unearthed accessible parts: 0.25mA; Earthed accessible parts: 3.5mA — P Measured protective conductor current (mA) ...... : — Max. allowed protective conductor current (mA) .. : — 5.1.7 Equipment with touch current exceeding 3,5 mA 5.1.7.1 General ................................................................ : N 5.1.7.2 Simultaneous multiple connections to the supply N 5.1.8 Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks 5.1.8.1 Limitation of the touch current to a telecommunication network or to a cable distribution system TRF No. SRENAV-01V1.4 The touch current does not exceed 3.5mA Not connected to a telecommunication network or cable distribution systems N N N Report No.: ACSS1811066 Page 23 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Supply voltage (V) ................................................ : — Measured touch current (mA) .............................. : — Max. allowed touch current (mA) ......................... : — Summation of touch currents from telecommunication networks N a) EUT with earthed telecommunication ports ..... : N b) EUT whose telecommunication ports have no reference to protective earth N 5.2 Electric strength P 5.2.1 General 5.2.2 Test procedure P 5.3 Abnormal operating and fault conditions P 5.3.1 Protection against overload and abnormal operation See appended table 5.3 P 5.3.2 Motors See appended annex B P 5.3.3 Transformers See appended annex C P 5.3.4 Functional insulation .............................................. : Complies with method c). P 5.3.5 Electromechanical components No electromechanical components in secondary circuits. N 5.3.6 Audio amplifiers in ITE ......................................... : The equipment does not contain audio amplifies. N 5.3.7 Simulation of faults (see appended table 5.3) P 5.3.8 Unattended equipment No thermostats, temperature limiters or thermal cut-outs N 5.3.9 Compliance criteria for abnormal operating and fault Refer to below: conditions P 5.3.9.1 During the tests No fire propagated beyond the equipment. No molten metal was emitted. No any hazard. P 5.3.9.2 After the tests Not reduction of clearance and creepage distances. Electric Strength tests performed after abnormal and fault tests. P 6 CONNECTION TO TELECOMMUNICATION NETWORKS The equipment is not connected to a TELECOMMUNICATION NETWORKS N 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment N 5.1.8.2 TRF No. SRENAV-01V1.4 See appended table 5.2 P Report No.: ACSS1811066 Page 24 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict 6.1.1 Protection from hazardous voltages N 6.1.2 Separation of the telecommunication network from earth N 6.1.2.1 Requirements N Supply voltage (V) ................................................ : — Current in the test circuit (mA) ............................ : — 6.1.2.2 Exclusions ............................................................ : N 6.2 Protection of equipment users from overvoltages on telecommunication networks N 6.2.1 Separation requirements N 6.2.2 Electric strength test procedure N 6.2.2.1 Impulse test N 6.2.2.2 Steady-state test N 6.2.2.3 Compliance criteria N 6.3 Protection of the telecommunication wiring system from overheating N Max. Output current (A) ........................................ : — Current limiting method ........................................ : — 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS The equipment is not connected to a CABLE DISTRIBUTION SYSTEMS. N 7.1 General N 7.2 Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment N 7.3 Protection of equipment users from overvoltages on the cable distribution system N 7.4 Insulation between primary circuits and cable distribution systems N 7.4.1 General N 7.4.2 Voltage surge test N 7.4.3 Impulse test N A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE N A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see 4.7.3.2) N A.1.1 Samples ................................................................ : — Wall thickness (mm) .............................................. : — TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 25 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test A.1.2 Conditioning of samples; temperature (C) .......... : N A.1.3 Mounting of samples ............................................ : N A.1.4 Test flame (see IEC 60695-11-3) N Flame A, B, C or D ............................................... : — A.1.5 Test procedure N A.1.6 Compliance criteria N Sample 1 burning time (s) ..................................... : — Sample 2 burning time (s) ..................................... : — Sample 3 burning time (s) ..................................... : — A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see 4.7.3.2 and 4.7.3.4) N A.2.1 Samples, material ................................................. : — Wall thickness (mm) .............................................. : — A.2.2 Conditioning of samples; temperature (°C) .......... : N A.2.3 Mounting of samples ............................................ : N A.2.4 Test flame (see IEC 60695-11-4) N Flame A, B or C .................................................... : — A.2.5 Test procedure N A.2.6 Compliance criteria N Sample 1 burning time (s) ..................................... : — Sample 2 burning time (s) ..................................... : — Sample 3 burning time (s) ..................................... : — Alternative test acc. to IEC 60695-11-5, cl. 5 and 9 N Sample 1 burning time (s) ..................................... : Sample 2 burning time (s) ..................................... : — — Sample 3 burning time (s) ..................................... : — A.3 Hot flaming oil test (see 4.6.2) N A.3.1 Mounting of samples N A.3.2 Test procedure N A.3.3 Compliance criterion N B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and 5.3.2) N B.1 General requirements N Position ................................................................ : — Manufacturer ........................................................ : — Type ..................................................................... : — A.2.7 TRF No. SRENAV-01V1.4 Result - Remark Verdict Report No.: ACSS1811066 Page 26 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Rated values ....................................................... : — B.2 Test conditions N B.3 Maximum temperatures N B.4 Running overload test N B.5 Locked-rotor overload test N Test duration (days) ............................................. : — Electric strength test: test voltage (V) .................. : — B.6 Running overload test for d.c. motors in secondary circuits N B.6.1 General N B.6.2 Test procedure N B.6.3 Alternative test procedure N B.6.4 Electric strength test; test voltage (V) .................. : N B.7 Locked-rotor overload test for d.c. motors in secondary circuits N B.7.1 General N B.7.2 Test procedure N B.7.3 Alternative test procedure N B.7.4 Electric strength test; test voltage (V) ................. : N B.8 Test for motors with capacitors N B.9 Test for three-phase motors N B.10 Test for series motors N Operating voltage (V) ........................................... : — ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3) P C Position ................................................................ : See appended table 1.5.1 — Manufacturer ........................................................ : See appended table 1.5.1 — Type ..................................................................... : See appended table 1.5.1 — Rated values ....................................................... : See appended table 1.5.1 — Method of protection ............................................. : — C.1 Overload test See appended table 5.3 P C.2 Insulation See appended table 5.2 Fixed by insulation tape and tube. P Protection from displacement of windings ............ : P D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see 5.1.4) P D.1 Measuring instrument P TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 27 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test D.2 Alternative measuring instrument N E ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13) N F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10 and Annex G) P G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES N G.1 Clearances N G.1.1 General G.1.2 Summary of the procedure for determining minimum clearances N N G.2 Determination of mains transient voltage (V) N G.2.1 AC mains supply .................................................. : N G.2.2 Earthed d.c. mains supplies ................................. : N G.2.3 Unearthed d.c. mains supplies ............................. : N G.2.4 Battery operation .................................................. : N G.3 Determination of telecommunication network transient voltage (V) ............................................. : N G.4 Determination of required withstand voltage (V) N G.4.1 Mains transients and internal repetitive peaks ..... : N G.4.2 Transients from telecommunication networks ..... : N G.4.3 Combination of transients N G.4.4 Transients from cable distribution systems N G.5 Measurement of transient voltages (V) N a) Transients from a mains supply N For an a.c. mains supply N For a d.c. mains supply N b) Transients from a telecommunication network N G.6 Determination of minimum clearances ................ : N H ANNEX H, IONIZING RADIATION (see 4.3.13) N J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) N Metal(s) used ....................................................... : — K Result - Remark ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8) TRF No. SRENAV-01V1.4 Verdict N Report No.: ACSS1811066 Page 28 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test K.1 Making and breaking capacity N K.2 Thermostat reliability; operating voltage (V) ......... : K.3 Thermostat endurance test; operating voltage (V) ............................................................................... : K.4 Temperature limiter endurance; operating voltage (V) ......................................................................... : K.5 Thermal cut-out reliability N K.6 Stability of operation N L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2) P L.1 Typewriters N L.2 Adding machines and cash registers N L.3 Erasers N L.4 Pencil sharpeners N L.5 Duplicators and copy machines N L.6 Motor-operated files N L.7 Other business equipment P M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N M.1 Introduction N M.2 Method A N M.3 Method B N M.3.1 Ringing signal M.3.1.1 Frequency (Hz) .................................................... : N — M.3.1.2 Voltage (V) ........................................................... : — M.3.1.3 Cadence; time (s), voltage (V) ............................. : — M.3.1.4 Single fault current (mA) ...................................... : — M.3.2 Tripping device and monitoring voltage ............... : N M.3.2.1 Conditions for use of a tripping device or a monitoring voltage N M.3.2.2 Tripping device N M.3.2.3 Monitoring voltage (V) .......................................... : — N ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1, 7.3.2, 7.4.3 and Clause G.5) N N.1 ITU-T impulse test generators N N.2 IEC 60065 impulse test generator N TRF No. SRENAV-01V1.4 Result - Remark Verdict Report No.: ACSS1811066 Page 29 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test P ANNEX P, NORMATIVE REFERENCES — Q ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1) P a) Preferred climatic categories ........................... : — b) Maximum continuous voltage .......................... : — c) Pulse current .................................................... : — R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES N R.1 Minimum separation distances for unpopulated coated printed boards (see 2.10.6.2) N R.2 Reduced clearances (see 2.10.3) N S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) N S.1 Test equipment N S.2 Test procedure N S.3 Examples of waveforms during impulse testing N T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2) N Not protected against ingress of water. — ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see 2.10.5.4) P Triple insulation wire was used. (See appended table 1.5.1) — V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) P V.1 Introduction P V.2 TN power distribution systems V.3 TT power distribution systems N V.4 IT power distribution systems N U Result - Remark Single-phase. TN power system considered and used for testing Verdict P W ANNEX W, SUMMATION OF TOUCH CURRENTS N W.1 Touch current from electronic circuits N W.1.1 Floating circuits N W.1.2 Earthed circuits N W.2 Interconnection of several equipments N W.2.1 Isolation N TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 30 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict W.2.2 Common return, isolated from earth N W.2.3 Common return, connected to protective earth N X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause C.1) P X.1 Determination of maximum input current See annex C.1 P X.2 Overload test procedure Electronic protection mode is used. P Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) N Y.1 Test apparatus ..................................................... : N Y.2 Mounting of test samples ..................................... : N Y.3 Carbon-arc light-exposure apparatus ................... : N Y.4 Xenon-arc light exposure apparatus .................... : N Z ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2) N AA ANNEX AA, MANDREL TEST (see 2.10.5.8) N BB ANNEX BB, CHANGES IN THE SECOND EDITION — CC ANNEX CC, Evaluation of integrated circuit (IC) current limiters N CC.1 General N CC.2 Test program 1…………………………………….: — CC.3 Test program 2…………………………………….: — DD ANNEX DD, Requirements for the mounting means of rack-mounted equipment N DD.1 General N DD.2 Mechanical strength test, variable N…………..: — DD.3 Mechanical strength test, 250N, including end stops…………………………………………………: — DD.4 Compliance…………………………………………: — EE ANNEX EE, Household and home/office document/media shredders N EE.1 General N EE.2 Markings and instructions N Use of markings or symbols………….…………: — TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 31 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Information of user instructions, maintenance and/or servicing instructions……………………: — EE.3 Inadvertent reactivation test………………….…: — EE.4 Disconnection of power to hazardous moving parts: N Use of markings or symbols……………………: — Protection against hazardous moving parts N Test with test finger (Figure 2A) ………...……: — Test with wedge probe (Figure EE1 and EE2) : — EE.5 TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 32 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 – CENELEC COMMON MODIFICATIONS Clause Contents (A2:2013) General General (A1:2010) General (A2:2013) 1.1.1 (A1:2010) Requirement + Test Result - Remark Verdict Clauses, subclauses, notes, tables and figures which are additional to those in IEC60950-1 and it´s amendmets are prefixed “Z” — Add the following annexes: Annex ZA (normative) — European Annex ZB (normative) Annex ZD (informative) Normative references to international publications with their corresponding publications Special national conditions IEC and CENELEC code designations for flexible cords Delete all the “country” notes in the reference document (IEC 60950-1:2005) according to the following list: 1.4.8 Note 2 1.5.1 Note 2 & 3 1.5.7.1 Note 1.5.8 Note 2 1.5.9.4 Note 1.7.2.1 Note 4, 5 & 6 2.2.3 Note 2.2.4 Note 2.3.2 Note 2.3.2.1 Note 2 2.3.4 Note 2 2.6.3.3 Note 2 & 3 2.7.1 Note 2.10.3.2 Note 2 2.10.5.13 Note 3 3.2.1.1 Note 3.2.4 Note 3. 5.1 Note 2 4.3.6 Note 1 & 2 4.7 Note 4 4.7.2.2 Note 4.7.3.1 Note 2 5.1.7.1 Note 3 & 4 5.3.7 Note 1 6 Note 2 & 5 6.1.2.1 Note 2 6.1.2.2 Note 6.2.2 Note 6.2.2.1 Note 2 6.2.2.2 Note 7.1 Note 3 7.2 Note 7.3 Note 1 & 2 G.2.1 Note 2 Annex H Note 2 Delete all the “country” notes in the reference document (IEC 609501:2005/A1:2010) according to the following list: 1.5.7.1 Note 6.1.2.1 Note 2 6.2.2.1 Note 2 EE.3 Note — Delete all the “country” notes in the reference document (IEC 609501:2005/A2:2013) according to the following list: 2.7.1 Note * 2.10.3.1 Note 2 6.2.2. Note * Note of secretary: Text of Common Modification remains unchanged. Replace the text of NOTE 3 by the following. — NOTE 3 The requirements of EN 60065 may also be used to meet safety requirements for multimedia equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. For television sets EN 60065 applies. TRF No. SRENAV-01V1.4 — N Report No.: ACSS1811066 Page 33 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test 1.3.Z1 Add the following subclause: 1.3.Z1 Exposure to excessive sound pressure The apparatus shall be so designed and constructed as to present no danger when used for its intended purpose, either in normal operating conditions or under fault conditions, particularly providing protection against exposure to excessive sound pressures from headphones or earphones. Result - Remark Verdict N NOTE Z1 A new method of measurement is described in EN 50332-1, Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 1: General method for “one package equipment”, and in EN 50332-2, Sound system equipment: Headphones and earphones associated with portable audio equipment Maximum sound pressure level measurement methodology and limit considerations - Part 2: Guidelines to associate sets with headphones coming from different manufacturers. (A12:2011) In EN 60950-1:2006/A12:2011 Delete the addition of 1.3.Z1 / EN 60950-1:2006 Delete the definition 1.2.3.Z1 / EN 60950-1:2006 /A1:2010 N 1.5.1 Add the following NOTE: N (Added info*) NOTE Z1 The use of certain substances in electrical and electronic equipment is restricted within the EU: see Directive 2002/95/EC. New Directive 2011/65/11 * 1.7.2.1 (A1:2010) 1.7.2.1 (A12.2011) In addition, for a PORTABLE SOUND SYSTEM, the instructions shall include a warning that excessive sound pressure from earphones and headphones can cause hearing loss. In EN 60950-1:2006/A12:2011 Delete NOTE Z1 and the addition for Portable Sound System. Add the following clause and annex to the existing standard and amendments. N Zx Protection against excessive sound pressure from personal music players N TRF No. SRENAV-01V1.4 N Report No.: ACSS1811066 Page 34 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Not personal music player Zx.1 General This sub-clause specifies requirements for protection against excessive sound pressure from personal music players that are closely coupled to the ear. It also specifies requirements for earphones and headphones intended for use with personal music players. Verdict N A personal music player is a portable equipment for personal use, that: is designed to allow the user to listen to recorded or broadcast sound or video; and primarily uses headphones or earphones that can be worn in or on or around the ears; and allows the user to walk around while in use. NOTE 1 Examples are hand-held or body-worn portable CD players, MP3 audio players, mobile phones with MP3 type features, PDA’s or similar equipment. A personal music player and earphones or headphones intended to be used with personal music players shall comply with the requirements of this sub-clause. The requirements in this sub-clause are valid for music or video mode only. The requirements do not apply: while the personal music player is connected to an external amplifier; or while the headphones or earphones are not used. NOTE 2 An external amplifier is an amplifier which is not part of the personal music player or the listening device, but which is intended to play the music as a standalone music player. The requirements do not apply to: hearing aid equipment and professional equipment; NOTE 3 Professional equipment is equipment sold through special sales channels. All products sold through normal electronics stores are considered not to be professional equipment. analogue personal music players (personal music players without any kind of digital processing of the sound signal) that are brought to the market before the end of 2015. NOTE 4 This exemption has been allowed because this technology is falling out of use and it is expected that within a few years it will no longer exist. This exemption will not be extended to other technologies. For equipment which is clearly designed or intended for use by young children, the limits of EN 71-1 apply. TRF No. SRENAV-01V1.4 N Report No.: ACSS1811066 Page 35 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Zx.2 Equipment requirements No safety provision is required for equipment that complies with the following: equipment provided as a package (personal music player with its listening device), where the acoustic output LAeq,T is ≤ 85 dBA measured while playing the fixed “programme simulation noise” as described in EN 50332-1; and a personal music player provided with an analogue electrical output socket for a listening device, where the electrical output is ≤ 27 mV measured as described in EN 50332-2, while playing the fixed “programme simulation noise” as described in EN 50332-1. NOTE 1 Wherever the term acoustic output is used in this clause, the 30 s A-weighted equivalent sound pressure level LAeq,T is meant. See also Zx.5 and Annex Zx. All other equipment shall: a) protect the user from unintentional acoustic outputs exceeding those mentioned above; and b) have a standard acoustic output level not exceeding those mentioned above, and automatically return to an output level not exceeding those mentioned above when the power is switched off; and c) provide a means to actively inform the user of the increased sound pressure when the equipment is operated with an acoustic output exceeding those mentioned above. Any means used shall be acknowledged by the user before activating a mode of operation which allows for an acoustic output exceeding those mentioned above. The acknowledgement does not need to be repeated more than once every 20 h of cumulative listening time; and NOTE 2 Examples of means include visual or audible signals. Action from the user is always required. NOTE 3 The 20 h listening time is the accumulative listening time, independent how often and how long the personal music player has been switched off. d) have a warning as specified in Zx.3; and e) not exceed the following: 1) equipment provided as a package (player with Its listening device), the acoustic output shall be ≤ 100 dBA measured while playing the fixed “programme simulation noise” described in EN 50332-1; and 2) a personal music player provided with an analogue electrical output socket for a listening device, the electrical output shall be ≤ 150 mV measured as described in EN 50332-2, while playing the fixed “programme simulation noise” described in EN 50332-1. TRF No. SRENAV-01V1.4 Result - Remark Verdict N Report No.: ACSS1811066 Page 36 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark For music where the average sound pressure (long term LAeq,T) measured over the duration of the song is lower than the average produced by the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dBA. In this case T becomes the duration of the song. Verdict N NOTE 4 Classical music typically has an average sound pressure (long term LAeq,T) which is much lower than the average programme simulation noise. Therefore, if the player is capable to analyse the song and compare it with the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dBA. For example, if the player is set with the programme simulation noise to 85 dBA, but the average music level of the song is only 65 dBA, there is no need to give a warning or ask an acknowledgement as long as the average sound level of the song is not above the basic limit of 85 dBA. Zx.3 Warning The warning shall be placed on the equipment, or on the packaging, or in the instruction manual and shall consist of the following: the symbol of Figure 1 with a minimum height of 5 mm; and the following wording, or similar: N “To prevent possible hearing damage, do not listen at high volume levels for long periods.” / Figure 1 – Warning label (IEC 60417-6044) Alternatively, the entire warning may be given through the equipment display during use, when the user is asked to acknowledge activation of the higher level. Zx.4 Requirements for listening devices (headphones and earphones) N Zx.4.1 Wired listening devices with analogue input With 94 dBA sound pressure output LAeq,T, the input voltage of the fixed “programme simulation noise” described in EN 50332-2 shall be ≥ 75 mV. N This requirement is applicable in any mode where the headphones can operate (active or passive), including any available setting (for example built-in volume level control). NOTE The values of 94 dBA – 75 mV correspond with 85dBA – 27 mV and 100 dBA – 150 mV. TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 37 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Zx.4.2 Wired listening devices with digital input With any playing device playing the fixed “programme simulation noise” described in EN 50332-1 (and respecting the digital interface standards, where a digital interface standard exists that specifies the equivalent acoustic level), the acoustic output LAeq,T of the listening device shall be ≤ 100 dBA. Result - Remark Verdict N This requirement is applicable in any mode where the headphones can operate, including any available setting (for example built-in volume level control, additional sound feature like equalization, etc.). NOTE An example of a wired listening device with digital input is a USB headphone. Zx.4.3 Wireless listening devices In wireless mode: with any playing and transmitting device playing the fixed programme simulation noise described in EN 50332-1; and respecting the wireless transmission standards, where an air interface standard exists that specifies the equivalent acoustic level; and with volume and sound settings in the listening device (for example built-in volume level control, additional sound feature like equalization, etc.) set to the combination of positions that maximize the measured acoustic output for the abovementioned programme simulation noise, the acoustic output LAeq,T of the listening device shall be ≤ 100 dBA. N NOTE An example of a wireless listening device is a Bluetooth headphone. Zx.5 Measurement methods Measurements shall be made in accordance with EN 50332-1 or EN 50332-2 as applicable. Unless stated otherwise, the time interval T shall be 30 s. N NOTE Test method for wireless equipment provided without listening device should be defined. 2.7.1 Replace the subclause as follows: Basic requirements To protect against excessive current, short-circuits and earth faults in PRIMARY CIRCUITS, protective devices shall be included either as integral parts of the equipment or as parts of the building installation, subject to the following, a), b) and c): a) except as detailed in b) and c), protective devices necessary to comply with the requirements of 5.3 shall be included as parts of the equipment; b) for components in series with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault protection may be provided by protective devices in the building installation; TRF No. SRENAV-01V1.4 P Report No.: ACSS1811066 Page 38 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test N 2.7.2 c) it is permitted for PLUGGABLE EQUIPMENT TYPE B or PERMANENTLY CONNECTED EQUIPMENT, to rely on dedicated overcurrent and short-circuit protection in the building installation, provided that the means of protection, e.g. fuses or circuit breakers, is fully specified in the installation instructions. If reliance is placed on protection in the building installation, the installation instructions shall so state, except that for PLUGGABLE EQUIPMENT TYPE A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet. This subclause has been declared ‘void’. 3.2.3 Delete the NOTE in Table 3A, and delete also in this table the conduit sizes in parentheses. N 3.2.5.1 Replace “60245 IEC 53” by “H05 RR-F”; “60227 IEC 52” by “H03 VV-F or H03 VVH2-F”; “60227 IEC 53” by “H05 VV-F or H05 VVH2-F2”. In Table 3B, replace the first four lines by the following: a) Up to and including 6 | 0,75 | b) Over 6 up to and including 10| (0,75) 1,0 | c) Over 10 up to and including 16| (1,0) 1,5 | In the conditions applicable to Table 3B delete the a) words “in some countries” in condition . In NOTE 1, applicable to Table 3B, delete the second sentence. N 3.2.5.1 NOTE Z1 The harmonized code designations corresponding to the IEC cord types are given in Annex ZD N 3.3.4 In Table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with the following: Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to 4 | Delete the fifth line: conductor sizes for 13 to 16 A N 4.3.13.6 Replace the existing NOTE by the following: N (A2:2013) (A1:2010) Result - Remark Verdict N NOTE Z1 Attention is drawn to: 1999/519/EC: Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz, and 2006/25/EC: Directive on the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents (artifical optical radiation). Standards taking into account mentioned Recommendation and Directive which demonstrate compliance with the applicable EU Directive are indicated in the OJEC. TRF No. SRENAV-01V1.4 N Report No.: ACSS1811066 Page 39 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Annex H Replace the last paragraph of this annex by: At any point 10 cm from the surface of the OPERATOR ACCESS AREA, the dose rate shall not exceed 1 μSv/h (0,1 mR/h) (see NOTE). Account is taken of the background level. Replace the notes as follows: Verdict N NOTE These values appear in Directive 96/29/Euratom. Delete NOTE 2. Bibliograp Additional EN standards. hy ZA NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR CORRESPONDING EUROPEAN PUBLICATIONS ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) Clause Requirement + Test 1.2.4.1 In Denmark, certain types of Class I appliances (see 3.2.1.1) may be provided with a plug not establishing earthing conditions when inserted into Danish socket-outlets. In Norway and Sweden, for requirements see 1.7.2.1 and 7.3 of this annex. In Finland, Norway and Sweden, resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in 1.5.7.1. In addition when a single resistor is used, the resistor must withstand the resistor test in 1.5.7.2. In Norway, due to the IT power system used (see annex V, Figure V.7), capacitors are required to be rated for the applicable line-to-line voltage (230 V). In Finland, Norway and Sweden, the third dashed No such construction. sentence is applicable only to equipment as defined in 6.1.2.2 of this annex. In Finland, Norway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text in the applicable countries shall be as follows: In Finland: "Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan" In Norway: “Apparatet må tilkoples jordet stikkontakt” In Sweden: “Apparaten skall anslutas till jordat uttag” 1.2.13.14 (A11:2009) 1.5.7.1 (A11:2009) 1.5.8 1.5.9.4 1.7.2.1 TRF No. SRENAV-01V1.4 Result - Remark Verdict N N N P N N Report No.: ACSS1811066 Page 40 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test 1.7.2.1 In Norway and Sweden, the screen of the cable distribution system is normally not earthed at the entrance of the building and there is normally no equipotential bonding system within the building. Therefore the protective earthing of the building installation need to be isolated from the screen of a cable distribution system. It is however accepted to provide the insulation external to the equipment by an adapter or an interconnection cable with galvanic isolator, which may be provided by e.g. a retailer. The user manual shall then have the following or similar information in Norwegian and Swedish language respectively, depending on in what country the equipment is intended to be used in: “Equipment connected to the protective earthing of the building installation through the mains connection or through other equipment with a connection to protective earthing – and to a cable distribution system using coaxial cable, may in some circumstances create a fire hazard. Connection to a cable distribution system has therefore to be provided through a device providing electrical isolation below a certain frequency range (galvanic isolator, see EN 60728-11).” N NOTE In Norway, due to regulation for installations of cable distribution systems, and in Sweden, a galvanic isolator shall provide electrical insulation below 5 MHz. The insulation shall withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min. N (A11:2009) Translation to Norwegian (the Swedish text will also be accepted in Norway): “Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller via annet jordtilkoplet utstyr – og er tilkoplet et kabel-TV nett, kan forårsake brannfare. For å unngå dette skal det ved tilkopling av utstyret til kabel-TV nettet installeres en galvanisk isolator mellom utstyret og kabel- TV nettet.” Translation to Swedish: ”Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via annan utrustning och samtidigt är kopplad till kabel-TV nät kan i vissa fall medfőra risk főr brand. Főr att undvika detta skall vid anslutning av utrustningen till kabel-TV nät galvanisk isolator finnas mellan utrustningen och kabel-TV nätet.” TRF No. SRENAV-01V1.4 Result - Remark Verdict Report No.: ACSS1811066 Page 41 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test 1.7.2.1 In Denmark, CLASS I PLUGGABLE EQUIPMENT TYPE A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text in Denmark shall be as follows: In Denmark: “Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til stikproppens jord.” In Denmark, socket-outlets for providing power to other equipment shall be in accordance with the Heavy Current Regulations, Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For STATIONARY EQUIPMENT the socket-outlet shall be in accordance with Standard Sheet DK 1-1b or DK 15a. N For CLASS II EQUIPMENT the socket outlet shall be in accordance with Standard Sheet DKA 1-4a. In Denmark, socket-outlets for providing power to other equipment shall be in accordance with the DS 60884-2-D1:2011. For class I equipment the following Standard Sheets are applicable: DK 1-3a, DK 1-1c, DK 1-1d, DK 1-5a or DK 1-7a, with the exception for STATIONARY EQUIPMENT where the socketoutlets shall be in accordance with Standard Sheet DK 1-1b, DK 1-1c, DK 1-1d or DK 1-5a. Socket outlets intended for providing power to Class II apparatus with a rated current of 2,5 A shall be in accordance with DS 60884-2-D1 standard sheet DKA 1-4a. Other current rating socket outlets shall be in compliance with by DS 60884-2-D1 Standard Sheet DKA 1-3a or DKA 1-3b. Justification the Heavy Current Regulations, 6c In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex. In Finland, Norway and Sweden there are additional requirements for the insulation. See 6.1.2.1 and 6.1.2.2 of this annex. In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex. In the United Kingdom, the current rating of the circuit shall be taken as 13 A, not 16 A. In the United Kingdom, to protect against excessive currents and short-circuits in the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3 shall be conducted, using an external protective device rated 30 A or 32 A. If these tests fail, suitable protective devices shall be included as integral parts of the DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met. N (A2:2013) 1.7.5 1.7.5 (A11:2009) 1.7.5 (A2:2013) 2.2.4 2.3.2 2.3.4 2.6.3.3 2.7.1 TRF No. SRENAV-01V1.4 Result - Remark Verdict N N N N N N N Report No.: ACSS1811066 Page 42 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test 2.10.5.13 In Finland, Norway and Sweden, there are additional requirements for the insulation, see 6.1.2.1 and 6.1.2.2 of this annex. In Switzerland, supply cords of equipment having a RATED CURRENT not exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC 60884-1 and one of the following dimension sheets: SEV 6532-2.1991 Plug Type 15, 3P+N+PE, 250/400 V, 10 A SEV 6533-2.1991 Plug Type 11, L+N, 250 V, 10 A SEV 6534-2.1991 Plug Type 12, L+N+PE, 250 V, 10A In general, EN 60309 applies for plugs for currents exceeding 10 A. However, a 16 A plug and socketoutlet system is being introduced in Switzerland, the plugs of which are according to the following dimension sheets, published in February 1998: SEV 5932-2.1998: Plug Type 25 , 3L+N+PE 230/400 V, 16 A 3.2.1.1 Result - Remark Verdict N N SEV 5933-2.1998:Plug Type 21, L+N, 250 V, 16A SEV 5934-2.1998: Plug Type 23, L+N+PE 250 V, 16 A 3.2.1.1 In Denmark, supply cords of single-phase equipment having a rated current not exceeding13 A shall be provided with a plug according to the Heavy Current Regulations, Section 107-2-D1. CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a. If poly-phase equipment and single-phase equipment having a RATED CURRENT exceeding 13 A is provided with a supply cord with a plug, this plug shall be in accordance with the Heavy Current Regulations, Section 107-2-D1 or EN 60309-2. TRF No. SRENAV-01V1.4 N Report No.: ACSS1811066 Page 43 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test 3.2.1.1 In Denmark, supply cords of single-phase equipment having a rated current not exceeding 13 A shall be provided with a plug according to DS 60884-2-D1. CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a. If a single-phase equipment having a RATED CURRENT exceeding 13 A or if a poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with the standard sheets DK 6-1a in DS 60884-2-D1 or EN 60309-2. Justification the Heavy Current Regulations, 6c N 3.2.1.1 In Spain, supply cords of single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to UNE 20315:1994. Supply cords of single-phase equipment having a rated current not exceeding 2,5 A shall be provided with a plug according to UNE-EN 50075:1993. CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules, shall be provided with a plug in accordance with standard UNE 20315:1994. If poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with UNE-EN 60309-2. N 3.2.1.1 In the United Kingdom, apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug, shall be fitted with a ‘standard plug’ in accordance with Statutory Instrument 1768:1994 - The Plugs and Sockets etc. (Safety) Regulations 1994, unless exempted by those regulations. N (A2:2013) Result - Remark Verdict NOTE ‘Standard plug’ is defined in SI 1768:1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug. 3.2.1.1 In Ireland, apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to I.S. 411 by means of that flexible cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory Instrument 525:1997 - National Standards Authority of Ireland (section 28) (13 A Plugs and Conversion Adaptors for Domestic Use) Regulations 1997. N 3.2.4 In Switzerland, for requirements see 3.2.1.1 of this annex. N TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 44 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test 3.2.5.1 In the United Kingdom, a power supply cord with conductor of 1,25 mm2 is allowed for equipment with a rated current over 10 A and up to and including 13 A. N 3.3.4 In the United Kingdom, the range of conductor sizes of flexible cords to be accepted by terminals for equipment with a RATED CURRENT of over 10 A up to and including 13 A is: 2 2 • 1,25 mm to 1,5 mm nominal cross-sectional area. N 4.3.6 In the United Kingdom, the torque test is performed using a socket outlet complying with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment 2:2003 and the plug part of DIRECT PLUG-IN EQUIPMENT shall be assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16 and 12.17, except that the test of 12.17 is performed at not less than 125 °C. Where the metal earth pin is replaced by an Insulated Shutter Opening Device (ISOD), the requirements of clauses 22.2 and 23 also apply. N 4.3.6 In Ireland, DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such devices shall comply with Statutory Instrument 526:1997 - National Standards Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets for domestic use) Regulations, 1997. N 5.1.7.1 In Finland, Norway and Sweden TOUCH CURRENT measurement results exceeding 3,5 mA r.m.s. are permitted only for the following equipment: • STATIONARY PLUGGABLE EQUIPMENT TYPE A that is intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied, for example, in a telecommunication centre; and has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR; and is provided with instructions for the installation of that conductor by a SERVICE PERSON; • STATIONARY PLUGGABLE EQUIPMENT TYPE B; • STATIONARY PERMANENTLY CONNECTED EQUIPMENT. N TRF No. SRENAV-01V1.4 Result - Remark Verdict Report No.: ACSS1811066 Page 45 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test 6.1.2.1 In Finland, Norway and Sweden, add the following text between the first and second paragraph of the compliance clause: If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. Alternatively for components, there is no distance through insulation requirements for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition - passes the tests and inspection criteria of 2.10.11 with an electric strength test of 1,5 kV multiplied by 1,6 (the electric strength test of 2.10.10 shall be performed using 1,5 kV), and - is subject to ROUTINE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kV. N It is permitted to bridge this insulation with an optocoupler complying with 2.10.5.4 b). N (A1:2010) It is permitted to bridge this insulation with a capacitor complying with EN 60384-14:2005, subclass Y2. A capacitor classified Y3 according to EN 6038414:2005, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN 6038414, which in addition to the Y3 testing, is tested with an impulse test of 2,5 kV defined in EN 609501:2006, 6.2.2.1; - the additional testing shall be performed on all the test specimens as described in EN 60384-14: - the impulse test of 2,5 kV is to be performed before the endurance test in EN 60384-14, in the sequence of tests as described in EN 60384-14. TRF No. SRENAV-01V1.4 Result - Remark Verdict Report No.: ACSS1811066 Page 46 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test 6.1.2.2 In Finland, Norway and Sweden, the exclusions are applicable for PERMANENTLY CONNECTED EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B and equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON. N 7.2 In Finland, Norway and Sweden, for requirements see 6.1.2.1 and 6.1.2.2 of this annex. The term TELECOMMUNICATION NETWORK in 6.1.2 being replaced by the term CABLE DISTRIBUTION SYSTEM. N 7.3 In Norway and Sweden, for requirements see 1.2.13.14 and 1.7.2.1 of this annex. N (A11:2009) TRF No. SRENAV-01V1.4 Result - Remark Verdict Report No.: ACSS1811066 Page 47 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict Annex ZD (informative) IEC and CENELEC code designations for flexible cords Type of flexible cord Code designations IEC CENELEC PVC insulated cords Flat twin tinsel cord 60227 IEC 41 H03VH-Y Light polyvinyl chloride sheathed flexible cord 60227 IEC 52 H03VV-F H03VVH2-F Ordinary polyvinyl chloride sheathed flexible cord 60277 IEC 53 H05VV-F H05VVH2-F Rubber insulated cords Braided cord 60245 IEC 51 H03RT-F Ordinary tough rubber sheathed flexible cord 60245 IEC 53 H05RR-F Ordinary polychloroprene sheathed flexible cord 60245 IEC 57 H05RN-F Heavy polychloroprene sheathed flexible cord 60245 IEC 66 H07RN-F Cords having high flexibility Rubber insulated and sheathed cord 60245 IEC 86 H03RR-H Rubber insulated, crosslinked PVC sheathed cord 60245 IEC 87 H03RV4-H Crosslinked PVC insulated and sheathed cord 60245 IEC 88 H03V4V4-H TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 48 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD 1.5.1 TABLE: list of critical components P object/part No. manufacturer/ trademark type/model technical data PCB Interchangeable Interchangeable V-0, Min. 130C UL 796 UL Metal enclosure Interchangeable Interchangeable Min. 1.0mm -- -- AC inlet (CON1) Zhe Jiang Bei Er Jia Electronic Co., Ltd. TECX-UNIONS TECHNOLOGY CORP Dongguan Better Electronics Technology Co., Ltd. Dongguan Hongda Electronic Technology Co., Ltd. Zhongshan Lanbao Electrical Appliances Co., Ltd. Suzhou Littelfuse OVS Ltd. XC Electronics (Shen Zhen) Corp. Ltd. DONGGUAN QUANTAI INDUSTRIAL CO LTD CHANGYUAN ELECTRONICS (SHENZHEN) CO LTD DONG GUAN HUANG FENG INSULATION MATERIAL CO LTD DONGGUAN GINO PLASTIC PRODUCTS CO LTD Joyin Co., Ltd. ST-A01-001L AC 250V ,10A EN60320-1 VDE 40013388 TU-301-AL AC 250V ,10A EN60320-1 522 T8AL, AC250V IEC/EN 60127-1 IEC/EN 60127-3 ENEC00647-A1 UL E220004 VDE 40019022 52FD 52FDP T8AL, AC250V IEC/EN 60127-1 VDE IEC/EN 60127-3 40034179 RTI-20 T8AL, AC250V IEC/EN 60127-1 IEC/EN 60127-3 VDE 40012120 218-series T8AL, AC250V 5F-Series T8AL, AC250V IEC/EN 60127-1 IEC/EN 60127-3 IEC/EN 60127-1 IEC/EN 60127-3 VDE 40013496 VDE 40009609 T-2 VW-1, 600V, 125°C UL224 UL E227336 CB-HFT, CB-HFT(XY), CYG-MT VW-1, 600V, 125°C UL224 UL E180908 HFT-2 VW-1, 600V, 125°C UL224 UL E236485 GINO S-901-600 600V 125 UL224 UL E472166 14N471K 14N821K Min. AC 300V, Min. 85C Min. 3000A Min. AC 300V, Min. 85C Min. 3000A IEC/EN 61051-1 IEC/EN 61051-2 IEC/EN 61051-2-2 IEC/EN 61051-1 IEC/EN 61051-2 IEC/EN 61051-2-2 VDE 005937 (Alternative) Fuse F1 (Alternative) (Alternative) (Alternative) (Alternative) Heat shrinkable Tube used on F1 (Alternative) (Alternative) (Alternative) Varistor (ZR1) (optional) (Alternative) Joyin Co., Ltd. TRF No. SRENAV-01V1.4 10S471K 10S821K 14S471K 14S821K standard mark(s) of 1 conformity ) VDE 40004658 Report No.: ACSS1811066 Page 49 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD (Alternative) JYA-NAY Co., Ltd. (Alternative) Centra Science Corp. (Alternative) Shantou HighNew Technology Dev. Zone Songtian Enterprise Co., Ltd. (Alternative) Lien Shun Electronics Co., Ltd. (Alternative) Success Electronics Co., Ltd. Y1-cap: (CY4, CY5) (optional) Dongguan Easygather Electronic Co., Ltd. (Alternative) Haohua Electronic Co., 10D471K 10D821K 14D471K 14D821K CNR-14D471K CNR-14D821K Min. AC 300V, Min. 105C Min. 3000A IEC/EN 61051-1 IEC/EN 61051-2 IEC/EN 61051-2-2 VDE 40023949 Min. AC 300V, Min. 105C Min. 3000A Min. AC 300V, Min. 105C Min. 3000A IEC/EN 61051-1 IEC/EN 61051-2 IEC/EN 61051-2-2 IEC/EN 61051-1 IEC/EN 61051-2 IEC/EN 61051-2-2 VDE 40008220 Min. AC 300V, Min. 105C Min. 3000A IEC/EN 61051-1 IEC/EN 61051-2 IEC/EN 61051-2-2 VDE 40005858 Min. AC 300V, Min. 105C Min. 3000A IEC/EN 61051-1 IEC/EN 61051-2 IEC/EN 61051-2-2 VDE 40030401 Max.2200pF. Min AC 400 Vac, 125°C, subclass Y1 IEC 60384-14 VDE 40022942 Max.2200pF. Min AC 400 Vac, 125°C, subclass Y1 Max.2200pF. Min AC 250 Vac, 125°C, subclass Y1 Max.2200pF. Min AC 250 Vac, 125°C, subclass Y1 IEC 60384-14 VDE 40003902 IEC 60384-14 VDE 40016157 IEC 60384-14 VDE 40025754 F Max.2200pF. Min AC 250 Vac, 125°C, subclass Y1 IEC 60384-14 VDE 40036393 CY Max.2200pF. Min AC 400 Vac, 125°C, subclass Y1 Max.2200pF. AC 400 Vac, 125°C, subclass Y1 Max.2200pF. Min AC 250 Vac, 125°C, subclass Y1 IEC 60384-14 VDE 40008912 EN 60384-14 TUV R50232059 IEC 60384-14 VDE 40020001 VDE 40020002 14D471K 14D821K 10D471K 10D821K 14D471K 14D821K SVR10D471K SVR10D821K SVR14D471K SVR14D821K DCF CT7 (Alternative) Welson Industrial WD Co., Ltd. (Alternative) Shantou HighNew Technology Dev. Zone Songtian Enterprise Co., Ltd. (Alternative) GUANGDONG SOUTH HONGMING ELECTRONIC SCIENCE & TECHNOLOGY CO LTD (Alternative) Hsuan Tai Electronic Co. Ltd. CD-Series (Alternative) JYA-NAY Co., Ltd. JN (Alternative) Success Electronics Co., Ltd. SB SE TRF No. SRENAV-01V1.4 VDE 40023049 Report No.: ACSS1811066 Page 50 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD (Alternative) Shenzhen Teruixiang Electronic Co., Ltd. (Alternative) DongGuan City Jiankun Electronics Technology Co. Ltd (Alternative) Kunshan Micro Capacitors Electronic Co., Ltd. (Alternative) Yinan Don's Electronic Component Co., Ltd. Y2-cap: Dongguan Easy(CY1, CY2) gather (optional) Electronic Co., Ltd. (Alternative) HAOHUA ELECTRONIC CO TY-Series JT-Series B-Series, E-Series CT81 DCF CT7 (Alternative) Hongzhi Enterprises Ltd. Y (Alternative) Jyh Chung Electronic Co., Ltd. JY (Alternative) JYA-NAY Co.,Ltd JY (Alternative) Shantou HighNew Technology Dev. Zone Songtian Enterprise Co., Ltd. (Alternative) Kunshan Micro Capacitors Electronic Co., Ltd. (Alternative) Hsuan Tai Electronic Co. Ltd. (Alternative) DongGuan City Jiankun Electronics Technology Co. Ltd X-cap: Dain Electronics (CX1, CX2, Co., Ltd. CX3) (optional) TRF No. SRENAV-01V1.4 CE Series F-Series CY JK series MPX Max.2200pF. Min AC 400 Vac, 125°C, subclass Y1 Max.2200pF. Min AC 250 Vac, 125°C, subclass Y1 IEC 60384-14 VDE 40031733 IEC 60384-14 VDE 40041534 Max.2200pF. Min AC 250 Vac, 125°C, subclass Y1 Max.2200pF. Min AC 250 Vac, 125°C, subclass Y1 Max.1000pF. Min AC 250 Vac, 125°C, subclass Y2 Max.1000pF. Min AC 250 Vac, 125°C, subclass Y2 Max.1000pF. Min AC 250 Vac, 125°C, subclass Y2 Max.1000pF. Min AC 300 Vac, 125°C, subclass Y2 Max.1000pF. Min AC 250 Vac, 125°C, subclass Y2 Max.1000pF. Min AC 250 Vac, 125°C, subclass Y2 IEC 60384-14 VDE 40016537 IEC 60384-14 VDE 135256 UL 60384-14 UL E252221 IEC 60384-14 VDE 40013601 IEC 60384-14 VDE 40038461 IEC 60384-14 VDE 123326 IEC 60384-14 TUV R50232061 IEC 60384-14 VDE 40025748 Max.1000pF. Min AC 250 Vac, 125°C, subclass Y2 Max.1000pF. Min AC 250 Vac, 125°C, subclass Y2 Max.1000pF. Min AC 250 Vac, 125°C, subclass Y2 IEC 60384-14 VDE 40016130 IEC 60384-14 VDE 118413 IEC 60384-14 VDE 40041536 AC 275 Vac; Max.0.47uF; Min.100°C, subclass X2 EN 60384-14 VDE 40018798 Report No.: ACSS1811066 Page 51 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD (Alternative) Carli Electronics Co., Ltd. MPX (Alternative) Dongguan Easygather Electronic Co., Ltd. (Alternative) Joey Electronics (Dong Guan) Co., Ltd. MKP (Alternative) Hongzhi Enterprises Ltd. MPX (Alternative) SHANTOU HIGH-NEW TECHNOLOGY DEVELOPMNT ZONE SONGTIAN ENTERPRISE CO LTD (Alternative) Shenzhen Su Rong Capacitors Co., Ltd. MPX (Alternative) Xiamen Wanming Electronics Co., Ltd. (Alternative) SURETOP TECHNOLOGY Co. Ltd. WPX/ MPX/ HQX/ UTX (Alternative) Jenn Fu Electronics Corporation MPX MPX MKP/MPX MPX (Alternative) ACEWIN Electric MEX Industrial Co. Ltd. AC 275 Vac; Max.0.47uF; Min.100°C, subclass X2 AC 300 Vac; Max.0.47uF; Min.105°C, subclass X2 AC 275 Vac; Max.0.47uF; Min.105°C, subclass X2 AC 275 Vac; Max.0.47uF; Min.100°C, subclass X2 AC 275 Vac; Max.0.47uF; Min.85°C, subclass X2 EN 60384-14 VDE 40008520 EN 60384-14 VDE 40022258 EN 60384-14 VDE 40032481 EN 60384-14 VDE 40023936 EN 60384-14 TUV R 50136379 AC 280 Vac; Max.0.47uF; Min.100°C, subclass X2 AC 275 Vac; Max.0.47uF; Min.110°C, subclass X2 AC 275 Vac; Max.0.47uF; Min.105°C, subclass X2 AC 275 Vac; Max.0.47uF; Min.110°C, subclass X2 AC 275 Vac; Max.0.47uF; Min.100°C, subclass X2 1M ohm, 1/4W EN 60384-14 VDE 40008924 EN 60384-14 VDE 40023119 EN 60384-14 VDE 40034508 EN 60384-14 VDE 40023085 EN 60384-14 VDE 40008614 EN 60950-1 Test with appliance Resistor(R17, R17A, R18, R18A) Interchangeable Interchangeable Electrolytic capacitor (C11) DB1 Bridge diode Line Filter (LF1) Interchangeable Interchangeable 330uFmax; 450V,105 -- Test with appliance Interchangeable Interchangeable Min600V; Min 6A Min105°C -- Test with appliance Test with appliance Dongguanshi PuHang Electronic Co.,Ltd. -Magnet wire Interchangeable -Core -- TRF No. SRENAV-01V1.4 T14*9*5C Interchangeable -- Copper wire, min130°C Ferrite -- UL1446 UL -- -- Report No.: ACSS1811066 Page 52 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD -Triple wire GREAT leoflon industrial co ltd -Varnish Interchangeable TRW(B) Interchangeable Copper wire, Min.130C Minimum 130°C. UL2353 UL E211989 UL1446 UL Min105°C -- Test with appliance Copper wire, min130°C Ferrite Copper wire, Min.130C Minimum 130°C. Min105°C UL1446 UL -UL2353 -UL E242198 UL1446 UL -- Test with appliance Copper wire, min130°C Ferrite UL1446 UL -- -- PBT, V-0, 130°C Minimum 130°C. UL 94 UL UL1446 UL Min105°C -- Test with appliance Copper wire, min130°C Ferrite UL1446 UL -- -- UL 94 UL UL1446 UL -- -- IEC 60747-5-5: 2011 VDE 40008087 IEC 60747-5-5: 2011 VDE 132249 EN 60747-5-5 : 2011 VDE 40007240 - Alt. Line Filter (LF1) Dongguan Ju T14*9*5C Rong Electronics Co., Ltd. -Magnet wire Interchangeable Interchangeable -Core --Triple wire Young Chang Silicone Co., Ltd -Varnish Interchangeable Line Filter (LF2, LF3) Dongguanshi PuHang Electronic Co.,Ltd. -Magnet wire Interchangeable -Core -- -STW-B Interchangeable T25*15*10C Interchangeable -- -Clapboard Interchangeable Interchangeable -Varnish Interchangeable Interchangeable - Alt. Dongguan Ju T20*12*8C Rong Electronics Co., Ltd. -Magnet wire Interchangeable Interchangeable Line Filter (LF2, LF3) -Core -- -- -Clapboard Interchangeable Interchangeable -Varnish Interchangeable Interchangeable Q1, Q2, Q4, Q5, Q6 Interchangeable Optocoupler (OP1, OP2, OP3) SHARP CORP ELECTRONIC COMPONENTS AND DEVICES GROUP (Alternative) Everlight Electronics Co., Ltd. Interchangeable PC817/PC123 EL817 (Alternative) Bright Led BPC817 Electronics Corp. TRF No. SRENAV-01V1.4 PBT, V-0, 130°C Minimum 130°C. Min500V. Q1, Q2, Q4, Q5 is min10A, Q6 is min2A double isolation, 100C, dTi measured>0.4 mm minimum double isolation, 100C, dTi measured>0.4 mm minimum double isolation, 100C, dTi measured>0.4 mm minimum Report No.: ACSS1811066 Page 53 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD (Alternative) Lite-On Technology Corporation LTV-817 (Alternative) COSMO Electronics Corporation C1010 (Alternative) COSMO Electronics Corporation KPC817 (Alternative) China Resources PC817 Semiconductor (ShenZhen) Ltd. (Alternative) Fairchild Semiconductor Pte Ltd H11A817 Transformer SHENZHEN (T1) FORD ELECTRONIC CO LTD GQ330W-T-1A -Wire Interchangeable -Bobbin CHANG CHUN PLASTICS CO.,LTD Interchangeable T200NA, -Insulation JINGJIANG Tape YAHUA PRESSURE SENSITIVE GLUE CO LTD -Varnish Interchangeable Interchangeable -Tube Interchangeable Interchangeable Transformer SHENZHEN (T2) FORD ELECTRONIC CO LTD -Bobbin Chang chun plastics Co Ltd -Insulation JINGJIANG Tape YAHUA PRESSURE SENSITIVE GLUE CO LTD -Varnish Interchangeable TRF No. SRENAV-01V1.4 PZ, CT GQ330W-LLCT1 T200NA, CT280 Interchangeable double isolation, 100C, dTi measured>0.4 mm minimum double isolation, 100C, dTi measured>0.4 mm minimum double isolation, 100C, dTi measured>0.4 mm minimum double isolation, 100C, dTi measured>0.4 mm minimum double isolation, 100C, dTi measured>0.4 mm minimum Class B EN 60747-5-5: 2011 VDE 40015248 EN 60747-5-5: 2011 VDE 40010469 EN 60747-5-5: 2011 VDE 101347 EN 60747-5-5: 2011 VDE 40039266 EN 60747-5-5: 2011 VDE 40026857 EN 60950-1 Tested with appliance Copper wire, Min.130°C. Phenolic, V-0, Min.150°C thickness: 0.8mm Polyethy lene tercphthalate film tape. Min.130°C UL1446 UL UL94 UL746C UL E59481 UL510 UL E165111 Minimum 130°C. Minimum 150°C. Class B UL1446 UL UL 224 UL EN 60950-1 Tested with appliance Phenolic, V-0, UL94 Min.150°C thickness: 0.8mm Flame retardant UL510 film insulating tape. Min.130°C UL E59481 Minimum 130°C. UL UL1446 UL E165111 Report No.: ACSS1811066 Page 54 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD -Triple SHENZHEN insulated wire KAIZHONG HEDONG NEW MATERIAL CO LTD -Wire Interchangeable TIW- B Triple insulated UL2353 wire, Min.130C UL E357240 Interchangeable UL1446 UL -Tube Interchangeable Interchangeable Copper wire, Min.130°C. Minimum 150°C. Min.130C UL 224 UL EN 60950-1 Tested with appliance Copper wire, Min.130°C. Min.130°C. UL1446 UL UL1446 UL T200NA Phenolic, V-0, Min.150°C UL94 UL746C UL (E59481) CT-280 Min.130°C UL510 UL (E165111) Interchangeable Min.150 °C, VW-1 Min.130C UL 224 UL EN 60950-1 Tested with appliance Copper wire, Min.130°C. Min.130°C. UL1446 UL UL1446 UL T200NA Phenolic, V-0, Min.150°C UL94 UL746C UL (E59481) CT-280 Min.130°C UL510 UL (E165111) Interchangeable Min.150 °C, VW-1 V-0, 125C. Min.thickness 0.25mm UL 224 UL UL 94 UL Inductance (L21) SHENZHEN FORD ELECTRONIC CO LTD -Wire Interchangeable Interchangeable -varnish Interchangeable Interchangeable -bobbin CHANG CHUN PLASTICS CO.,LTD -insulation JINGJIANG tape YAHUA PRESSURE SENSITIVE GLUE CO LTD -tube Interchangeable Inductance (T3) GQ330W-LLCT2 SHENZHEN FORD ELECTRONIC CO LTD -Wire Interchangeable Interchangeable -varnish Interchangeable Interchangeable -bobbin CHANG CHUN PLASTICS CO.,LTD -insulation JINGJIANG tape YAHUA PRESSURE SENSITIVE GLUE CO LTD -tube Interchangeable Insulation sheet Between plug pin and PCB trace Interchangeable TRF No. SRENAV-01V1.4 GQ330W-PFCT1 Interchangeable Report No.: ACSS1811066 Page 55 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD DC fan (two provide) DONGGUAN YIN HAI PLASTIC ELECTRONICS CO.,LTD YH4020L05LCF50N Heat shrinkable tubing for Internal Wiring Thermal controller (TH5) SHENZHEN RSFR-H WOLIDA TRADING CO LTD Changzhou KW-*** Ainuo Electronics Technical Co., Ltd. Heatsink(HS1) --Heatsink(HS2) -- -- Heatsink(HS3) -- -- Heatsink(HS4) -- -- Heatsink(HS5) -- -- Heatsink(HS6) -- -- Heatsink for -U3 on the mainboard Heatsink for -U7 and U8 on the mainboard -- supplementary information:-- TRF No. SRENAV-01V1.4 -- DC5V, 0.13A EN 60950-1: 2006/A2:2013 CE by Shenzhen Tian Hai test technology Co.,Ltd (Report No.: TH16FR392S. Certificate No.: TH16FR392S.) UL E329530 Min.125 °C, 0.4mm. Rated VW-1. UL 224 250Vac, 0~165°C EN 60730-1, EN 60730-2 VDE 40030067 Metal, see attachment B for details Metal, see attachment B for details Metal, see attachment B for details Metal, see attachment B for details Metal, see attachment B for details Metal, see attachment B for details Metal, 34.6mm x 35.0mm x 20mm Metal, 28.0mm x 28.0mm x 11.0mm -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Report No.: ACSS1811066 Page 56 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD 1.7.11 TABLE: Marking durability test Marking type Checked by stick on EUT printed on EUT molded on EUT P Duration Result Water 15s Curling: Yes No; Legibility: Yes No Petroleum spirit 15s Curling: Yes No; Legibility: Yes No Note(s): -- 1.6.2 TABLE: Input test P Fuse # Irated (A) U (V) F (Hz) I (A) P (W) Condition/status F1 -- 90 50/60 3.632/3.631 325.29/325.21 Max normal load F1 5.0 100 50/60 3.237/3.229 322.83/322.79 Max normal load F1 5.0 240 50/60 1.323/1.334 307.30/307.23 Max normal load F1 -- 264 50/60 1.254/1.260 306.54/306.44 Max normal load Note(s): The measured steady input current at rated supply voltage shall not exceed the rated current by more than 10% under normal load. Max. normal load: All the output ports pull load to maximum rating. TABLE: Max. V, A, VA measurement 2.1.1.5 P Output tested Output current (rated) (A) Voltage (max.) (V) Current (max.) (A) VA (max.) (VA) POE port #1 55Vdc -- 53.64 0.221 11.69 HAZ/EL (Yes / No ) Yes No Note(s): Input voltage: 264 V/ 60 Hz Output which exceeds 240 VA is considered to be at hazardous energy level (HAZ/EL). 2.1.1.7 Location Condition L-N P TABLE: Discharge test Standby V peak 37% V peak V peak at tc 370 136.9 705ms Comment Pluggable equipment type A Note(s): Input voltage: 264 V/ 60 Hz; X capacitor: X capacitor: CX1= CX2= CX3=0.47uF, discharge resistor(s): R17=R17A=R18=R18A=1M ohm The voltage at the external point of disconnection shall decay to less than 37% of its original value in 1.0 second. 2.2.2 P TABLE: Hazardous voltage measurement Component Location Max. voltage (V) (normal operation) V peak V d.c. Voltage Limiting Components T1 Pin 5– GND 26.6 -- -- T2 Pin 7–GND 5.3 -- -- TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 57 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Pin 9–GND 55 -- -- Pin 10–GND 55 -- -- After D6 -- 55.8 D7 After D7 -- 55.8 D8 Note(s): Input voltage: 2.2.3 264 V/ 60 Hz P TABLE: SELV reliability test Accessible Part Component From - To Fault Comment Max. voltage (V) (fault condition) V peak V d.c. After D7 -GND D7 S/C -- 0 Shutdown After D8 -GND D8 S/C -- 0 Shutdown Note(s): Input voltage: 2.4 264 V/ 60 Hz P TABLE: Limited current circuits test Location Voltage (V) Current (mA) Freq. (kHz) Limit (mA) CY4 secondary Pin to “GND” 3.56 1.78 64.7 45.29 CY5 secondary Pin to “GND” 4.82 2.41 64.1 44.87 Note(s): Input voltage: 264 V/ 60 Hz; Y Capacitor: CY4=CY5=2200pF 2.5 TABLE: Limited power sources test Output tested Location P Single fault From To POE ports #1 Pins(3,6) Pin (7,8) POE ports #1 Pins(3,6) POE ports #1 Measured Maximum Limited Uoc (V) Isc (A) VA Isc (A) VA Normal 53.64 0.221 11.69 2.79 100 Pin (7,8) D7 S/C 53.66 0.221 11.69 2.79 100 Pins(3,6) Pin (7,8) J7 (1-7) S/C 0 0 0 8 100 RJ45 ports All pins GND Normal 0 0 0 8 100 SFP ports Pins (15,16) GND Normal 3.30 0 0 8 100 Note(s): Input voltage: 2.6.3.4 Test point between 264 V/ 60 Hz TABLE: Earthing test Current (A) TRF No. SRENAV-01V1.4 Duration (min) Measured resistance or voltage drops (ohms or V) P Limited resistance or voltage drops (ohms or V) Report No.: ACSS1811066 Page 58 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD AC inlet earth pin to furthest metal enclosure 32 2 0.003 ohms 0.1ohms AC inlet earth pin to CY1 secondary pin 32 2 0.003 ohms 0.1ohms AC inlet earth pin to CY2 secondary pin 32 2 0.004 ohms 0.1ohms Note(s):-- 2.9.2 P TABLE: Humidity conditioning test Test condition 20-30°C at 90-96% R.H. for 48h 40±2°C at 90-96%R.H. for 120h (tropical) Actural condition After humidity conditioning 40°C at 96% R.H. for 120h Unit DID breakdown DID NOT no See table 5.2 Note(s): 2.10.2 TABLE: Working voltage measurement Component Location From Pin 1 Pin 3 T1 Peak Voltage (Vac) RMS Voltage (Vac) Comments To Pin 6, 7 200 117 -- Pin 8, 9 158 117 -- Pin 6, 7 250 124 -- Pin 8, 9 241 124 -- Pin 6, 7 550 162 * Pin 8, 9 533 155 -- Pin 6, 7 191 117 -- Pin 8, 9 200 117 -- Pin 7 250 154 -- Pin 8, 9 283 157 -- Pin 10, 11 300 168 -- Pin 12 283 163 -- Pin 7 400 214 -- Pin 8, 9 458 251 * Pin 10, 11 358 189 -- Pin 12 416 213 -- Pin 4 Pin 5 Pin 1 T2 Pin 5 TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 59 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Pin 1 OP1 Pin 2 Pin 1 OP2 Pin 2 Pin 1 OP3 Pin 2 Pin 3 300 145 -- Pin 4 300 144 -- Pin 3 300 145 -- Pin 4 300 145 -- Pin 3 275 139 -- Pin 4 275 140 -- Pin 3 275 139 -- Pin 4 275 139 -- Pin 3 241 172 -- Pin 4 241 171 -- Pin 3 241 172 -- Pin 4 241 171 -- CY1 Pri Sec 350 240 -- CY2 Pri Sec 350 240 -- CY4 Pri Sec 200 121 -- CY5 Pri Sec 287 140 -- Note(s): Input: 240 V/ 60 Hz. The * indicate the maximum Peak voltage or RMS voltage. 2.10.3 and 2.10.4 TABLE: Clearances and creepage distances measurement Rated supply voltage: 100-240V Location Pollution degree: Operating Voltage 2 P Material Group: Clearance (mm) Creepage (mm) IIIb CTI V peak V rms Min Actual Min Actual -- Between primary and protective earth near ac inlet, as basic <420 <250 2.0 3.3 2.5 3.3 < 175 Opposite pattern traces before fuse (F1) on PCB, as basic <420 <250 2.0 3.6 2.5 3.6 < 175 Primary fuse (F1), pattern traces on PCB, as basic <420 <250 2.0 4.5 2.5 4.5 < 175 Pattern traces, between Primary and Secondary (OP3) on PCB, as reinforced <420 <250 4.0 6.7 5.0 6.7 < 175 Pattern traces, between Primary and Secondary (CY4) on PCB, as reinforced <420 <250 4.0 7.5 5.0 7.5 < 175 Between primary and secondary (T1) on traces side, as reinforced 550 240 4.4 7.5 4.8 7.5 < 175 TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 60 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Between primary and secondary (T1), as reinforced Between primary and core(T1), as basic Between secondary and core (T1), as basic Between primary and secondary (T2) on traces side, as reinforced Between primary and secondary (T2), as reinforced Between primary and core(T2), as reinforced 550 240 4.4 7.5 4.8 7.5 < 175 550 240 2.2 3.9 2.4 3.9 < 175 550 240 2.2 3.9 2.4 3.9 < 175 458 251 4.0 20.9 4.8 20.9 < 175 458 251 4.0 10.8 4.8 10.8 < 175 458 251 2.0 12.8 2.4 14.1 < 175 Note(s): B=Basic insulation, D/R= double insulation or reinforce insulation. - No components reduce distance after 10N steady force applied. - One Mylar sheet is cover power board both sides to isolate metal enclosure. - T2 primary wire used triple insulation wire, core as secondary. TABLE: Distance through insulation measurement 2.10.5 P U peak (V) U rms (V) Test voltage (V) 1. Insulation tape wrapped on transformer (T1), Reinforced, 2 layers (one layer tested) 550 240 3000Vac At least 2 layers 2layers 2. Insulation tape wrapped on transformer (T2), Reinforced, 2 layers (one layers tested) 458 251 3000Vac At least 2 layers 2layers 3. Mylar sheet (for power board) 550 240 1820Vac -- 0.25mm 4. Heat shrinkable tubing for Internal Wiring 550 240 3000Vac -- 0.40mm Distance through insulation (DTI) at/of: Required dti (mm) dti (mm) Note(s):-- 4.2.2, TABLE: Steady force test 4.2.3, 4.2.4 P Location Force duration Components 10N±1N 5s Location Force duration -- 30N±1N -- Location Force duration Metal enclosure 250N±10N 5s Result Unit Unit DID DID DID NOT show damage DID NOT breakdown Result Unit Unit DID DID DID NOT show damage DID NOT breakdown Result Unit DID DID NOT show damage Unit DID DID NOT breakdown Note(s): -- 4.2.5 TABLE: Impact test TRF No. SRENAV-01V1.4 P Report No.: ACSS1811066 Page 61 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Location Vertical distance Metal enclosure outside, top and sides of power supply Result Unit Unit 1.3 m DID DID DID NOT show damage DID NOT breakdown Note(s): -- 4.4.5 TABLE: protection against moving fan blades Fan location P Mass of fan assembly (m) (kg) Radius of fan blade (r) (mm) Rotational speed (N) (r/min) K factor calculated 0.008 20 5500 58.08 Left side of enclosure Classification of fan **) Result a). not likely to cause pain or injury fan of classification a): 0.39 b). likely to cause pain, but not likely to cause injury fan of classification b): c). does not comply with a) or b), likely to cause injury fan of classification c): Note(s): *) K factor calculation: K = 6 x 10-7 (mr2N2) **) classification of fan calculation: classification a): 4.5.2 classification b): TABLE: Thermal requirements P Supply voltage (V) ....................................... : 90V, 60Hz 264V, 60Hz Test times .................................................... : 3hrs 07mins 1hr 50mins -- Tam a1(C) ................................................. : See below See below -- Tam a2(C) .................................................. : See below See below -- Maximum measured temperature T of part/at: Measured T (C) Calculate T (50C) Measured (C) Calculated Allowed T (50C) Tmax (C) 1. AC inlet, inside 40.7 66.1 32.0 57.0 70 2. CY2 body 37.0 62.4 31.1 56.1 125 3. ZR1 body 40.2 65.6 31.5 56.5 85 4. LF1 winding 47.0 72.4 32.5 57.5 105 5. LF3 winding 51.7 77.1 36.2 61.2 105 6. LF2 winding 53.9 79.3 36.7 61.7 105 7. CX3 body 48.7 74.1 35.7 60.7 85 8. PCB near BD1 61.3 86.7 40.7 65.7 130 9. PCB near Q1 87.1 112.5 55.5 80.5 130 10. PCB near Q2 82.5 107.9 52.2 77.2 130 11. PCB near Q4 69.6 95.0 52.1 77.1 130 Report No.: ACSS1811066 Page 62 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD 12. PCB near Q5 60.5 85.9 47.4 72.4 130 13. PCB near D2 81.9 107.3 54.9 79.9 130 14. L21 winding 55.3 80.7 48.9 73.9 105 15. T3 winding 71.1 96.5 48.4 73.4 105 16. T2 winding 61.7 87.1 58.6 83.6 110 17. RT1 body 83.0 108.4 52.2 77.2 130 18. CY5 body 61.5 86.9 57.0 82.0 125 19. DP2 body 59.7 85.1 55.6 80.6 100 20. C11 body 51.7 77.1 42.4 67.4 85 21. T1 winding 52.2 77.6 50.1 75.1 110 22. PCB near D3 56.8 82.2 49.9 74.9 130 23. PCB near D7 63.5 88.9 61.8 86.8 130 24. PCB near D8 63.9 89.3 62.6 87.6 130 25. PCB near D5 49.9 75.3 47.8 72.8 130 26. Mylar sheet bottom under T2 51.5 76.9 49.6 74.6 125 27. Mylar sheet top under T2 54.1 79.5 51.7 76.7 125 28. Heat sink for U7 47.4 72.8 47.4 72.4 130 29. Heat sink for U3 53.0 78.4 53.7 78.7 130 30. U21 body 42.7 68.1 43.0 68.0 130 31. J4 body 30.9 56.3 31.3 56.3 130 32. Fan body 53.0 78.4 40.4 65.4 -- 33. Panel 32.3 57.7 31.8 56.8 80 34. BD2 body 57.7 83.1 48.2 73.2 130 35. Metal enclosure outside top of T2 35.7 61.1 31.7 56.7 70 36. Heat sink for U8 52.2 77.6 52.6 77.6 130 37. Ambient 24.6 50.0 25.0 50.0 -- Note(s): -- 4.6.1, 4.6.2 TABLE: opening in enclosure Opening position dimension(mm) remark Front -- No openings. Top -- No openings. Left P Height: 3.85mm Length: 2.85mm, 2.45mm Trapezoid. Cover three circle areas for DC fan: φ37.85mm; Height: 3.85mm φ37.85mm; φ37.85mm. Length: 2.05mm, 1.70mm Right Rear TRF No. SRENAV-01V1.4 φ2.25mm Circle. Cover a rectangular area: 22.4mm x 102.4mm. -- No openings. Report No.: ACSS1811066 Page 63 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Bottom -- No openings. 5.1.6 – 5.1.8 TABLE: Touch current measurement Measured between: P Measured (mA) Limit (mA) Comments/conditions Line & neutral and output terminal 0.105 0.25 Fuse in, “e” closed Line & neutral and metal enclosure 0.630 3.5 Fuse in, “e” opened Note(s): -5.2 TABLE: Electric strength test P Test voltage applied between: Test voltage (V) Breakdown 1500Vac No -- -- - Unit: Primary to metal enclosure 1820Vac No - T1: Primary to Core 1820Vac No - T1: Secondary to Core 1820Vac No -- -- - T1: Primary to Secondary 3000Vac No - T2: Core to Primary 3000Vac No - T2: Primary to Secondary 3000Vac No - Unit: Primary to Secondary output terminals 3000Vac No - Unit: Between main poles (Pri.fuse-link disconnected) Between parts separated by basic or supplementary insulation Between parts separated by double or reinforced insulation Note(s): 5.3 No. 1 TABLE: Fault condition test P Ambient temperature (C) ................................... : See below — Power source for EUT: Manufacturer, model/type, output rating ......................................................... : -- — Component Ventilation openings Fault Test voltage (V/Hz) Blocked 240V/ 60Hz TRF No. SRENAV-01V1.4 Test time Fuse # 2hours F1 24mins Fuse. current (A) 1.334 Result Unit operated normally, Max temperature measured on: T1 winding:52.1℃; T2 winding: 70.0℃; Ambient: 25.0℃. Recoverable when fault removed, NCD, NC, NT, NB, NH. Report No.: ACSS1811066 Page 64 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD 2 System Fan (1&2) Stalled 240V/ 60Hz 2hour F1 37mins 1.334 Unit operated normally, Max temperature measured on: T1 winding:54.3℃; T2 winding: 78.6℃; Ambient: 23.7℃. Recoverable when fault removed, NCD, NC, NT, NB, NH. 3 (After D5) 5V O/L 240V/ 60Hz 3hours F1 33mins 1.390→ 1.440→ 1.473→ 0.3 Unit shut down when overloaded to 5.4A.No damaged,nohazardous. T1 winding:75.7℃; T2 winding: 65.3℃; Ambient: 24.0℃.. Recoverable when fault removed, NCD, NC, NT, NB, NH. 4 (After D6,D7)55V O/L 240V/ 60Hz 3hours F1 21mins 1.797→ 1.847→ 1.870→ 0.34 Unit shut down when overloaded to 2.4A.No damaged,nohazardous. T1 winding:57.2℃; T2 winding:75.2℃; Ambient: 25.6℃.. Recoverable when fault removed, NCD, NC, NT, NB, NH. 5 DB1 S/C 240V/ 60Hz 1 Sec F1 0 Unit shutdown immediately, Fuse F1opened. NB, NH, NT,NC. 6 C11 S/C 240V/ 60Hz 1 Sec F1 0 Unit shutdown immediately, Fuse F1 opened. NB, NH,NT,NC. 7 U9 S/C Pin12 –pin14 240V/ 60Hz 10mins F1 0.105 Unit shutdown immediately, CD(U9), NT,NC,NB,NH. 8 U9 S/C Pin12 –Pin10 240V/ 60Hz 10mins F1 0.133 Unit shutdown immediately. Recoverable when fault removed, NCD, NC, NT, NB, NH. 9 Q1 PinG- PinS S/C 240V/ 60Hz 10mins F1 1.323 Normal operation, NCD, NC, NT, NB, NH. 10 Q1 PinG- PinD S/C 240V/ 60Hz 1 Sec F1 0 Unit shutdown immediately, F1 opened CD(Q2,Q1) NB, NH NC,NT. 11 Q1 PinS- PinD S/C 240V/ 60Hz 1 Sec F1 0 Unit shutdown immediately, Fuse F1 opened. NB, NH NT,NC. 12 Q2 PinG- PinS S/C 240V/ 60Hz 10mins F1 1.323 Normal operation, NCD, NC, NT, NB, NH. 13 Q2 PinG- PinD S/C 240V/ 60Hz 1 Sec F1 0 Unit shutdown immediately, Fuse F1 opened. NB, NH NT,NC. 14 Q2 PinS- PinD S/C 240V/ 60Hz 1 Sec F1 0 Ditto. 15 Q4 PinG- PinS S/C 240V/ 60Hz 10mins F1 0.140 Unit shutdown immediately. Recoverable when fault removed, NCD, NC, NT, NB, NH. 16 Q4 PinG- PinD S/C 240V/ 60Hz 10mins F1 0.140 Ditto. TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 65 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD 17 Q4 PinS- PinD S/C 240V/ 60Hz 10mins F1 0.152 Ditto. 18 Q5 PinG- PinS S/C 240V/ 60Hz 10mins F1 0.149 Ditto. 19 Q5 PinG- PinD S/C 240V/ 60Hz 10mins F1 0.152 Ditto. 20 Q5 PinS- PinD S/C 240V/ 60Hz 10mins F1 0.152 Ditto. 21 OP1 Pin1- Pin 2 S/C 240V/ 60Hz 10mins F1 0.126 Ditto. 22 OP1 Pin3- Pin 4 S/C 240V/ 60Hz 10mins F1 0.127 Ditto. 23 OP1 Pin1 O/C 10mins F1 0.126 Ditto. 24 OP1 Pin3 O/C 10mins F1 0.126 Ditto. 25 OP2 Pin1- Pin 2 S/C 240V/ 60Hz 240V/ 60Hz 240V/ 60Hz 10mins F1 1.323 Normal operation, NCD,NT,NC,NB, NH. 26 OP2 Pin3- Pin 4 S/C 240V/ 60Hz 10mins F1 0.127 Unit shutdown immediately. Recoverable when fault removed, NCD, NC, NT, NB, NH. 27 OP2 Pin1 O/C 240V/ 60Hz 10mins F1 1.320 Normal operation, NCD,NT,NC,NB, NH. 28 OP2 Pin3 O/C 240V/ 60Hz 10mins F1 0.127 Unit shutdown immediately. Recoverable when fault removed, NCD, NC, NT, NB, NH. 29 OP3 Pin1- Pin 2 S/C 240V/ 60Hz 10mins F1 0.107↔ 0.243 Unit shut down and cycle, 0.14W↔10.89W, Recoverable NCD, NH 30 OP3 Pin3- Pin 4 S/C 240V/ 60Hz 10mins F1 0.107 Unit shutdown immediately. Recoverable when fault removed, NCD, NC, NT, NB, NH. 31 OP3 Pin1 O/C 240V/ 60Hz 10mins F1 0.107↔ 0.243 32 OP3 Pin3 O/C 240V/ 60Hz 10mins F1 0.107↔ 0.243 Unit shut down and cycle, 0.14W↔10.89W, Recoverable NCD, NH Unit shut down and cycle, 0.14W↔10.89W, Recoverable NCD, NH Note(s):-- TRF No. SRENAV-01V1.4 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment A: Photo-documentation Page 1 of 5 Fig. 1 - Overview (1) Fig. 2 - Overview (2) TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 66 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment A: Photo-documentation Page 2 of 5 Fig. 3 - Internal view (1) Fig. 4 - Internal view (2) TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 67 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment A: Photo-documentation Page 3 of 5 Fig. 5 - Internal view (3) Fig. 6 - Power board overview 1 TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 68 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment A: Photo-documentation Page 4 of 5 Fig. 7 - Power board overview 2 Fig. 8 - Main board overview 1 TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 69 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment A: Photo-documentation Page 5 of 5 Fig. 9 –Main board overview 2 Fig. 10 –terminals TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 70 of 83 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment B: Drawing of Heatsink(HS1) TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 71 of 83 Page 1 of 6 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment B: Drawing of Heatsink(HS2) TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 72 of 83 Page 2 of 6 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment B: Drawing of Heatsink(HS3) TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 73 of 83 Page 3 of 6 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment B: Drawing of Heatsink(HS4) TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 74 of 83 Page 4 of 6 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment B: Drawing of Heatsink(HS5) TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 75 of 83 Page 5 of 6 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment B: Drawing of Heatsink on the Power board TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 76 of 83 Page 6 of 6 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment C: Schematic diagram and layout for power board TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 77 of 83 Page 1 of 3 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment C: Schematic diagram and layout for power board TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 78 of 83 Page 2 of 3 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment C: Schematic diagram and layout for power board TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 79 of 83 Page 3 of 3 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment D: Transformer T1 specification TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 80 of 83 Page 1 of 2 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment D: Transformer T1 specification TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 81 of 83 Page 2 of 2 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment E: Transformer T2 specification TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 82 of 83 Page 1 of 2 AUDIX TECHNOLOGY (SHENZHEN) CO., LTD Attachment E: Transformer T2 specification --- End of this page --- TRF No. SRENAV-01V1.4 Report No.: ACSS1811066 Page 83 of 83 Page 2 of 2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Create Date : 2018:11:30 09:39:53+08:00 Modify Date : 2018:11:30 10:03:20+08:00 Metadata Date : 2018:11:30 10:03:20+08:00 Producer : EPSON Scan Format : application/pdf Document ID : uuid:5dcb8d23-c78a-4c32-91eb-9c7cde25dcaa Instance ID : uuid:15dc9a30-645f-4d3e-b9cd-52f010042981 Has XFA : No Page Count : 84EXIF Metadata provided by EXIF.tools