AUDIX TECHNOLOGY (SHENZHEN) CO., LTD

Report No.: ACSS1811066
Page 2 of 83

Copy of marking plate

(Remark: Above label stuck on the outside of enclosure)
Note(s):
- The marking plate(s) artwork appended to this report may be only a draft. The use of certification
marks on a product must be authorized by the respective NCBs that own these marks.)
- The height of CE symbol should be 5.0 mm Min.
Summary of testing:
Following symbols and abbreviations may be used in this test report.
F= Function Insulation
B= Basic Insulation
S= Supplementary Insulation
D/R= Double or Reinforced Insulation
S/C= Short-Circuit
O/C= Open-Circuit
O/L= Over-Load
B/L= Block
IP= Internal protection operated (list component)
CT= Constant temperatures were obtained
CD= Components damaged (list damaged components)
NB= No indication of dielectric breakdown
NC= Cheesecloth remained intact
NT= Tissue paper remained intact
NH= No hazard occured
Pri.= Primary
Sec.= Secondary
PCB= Printed Circuit Board
PSU= Power Supply Unit
EUT= Equipment Under Test
EPS= External Power Supply

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 3 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Test item particulars:
Equipment mobility………........................................ …:

[x] movable [] hand-held
[] transportable
[] stationary [] for building-in [] direct plug-in
[] rack-mounted

Connection to the mains ………………………..………:

[x] pluggable equipment: [x] type A [] type B
[] permanent connection
[x] detachable power supply cord
[] non-detachable power supply cord
[] not directly connected to the mains

Operation condition …………………………………..…:

[x] continuous
[] rated operating / resting time:

Access location ......................................................... :

[x] operator accessible
[] restricted access location

Over voltage category (OVC) ................................... :

[] OVC I
[] other:

Mains supply tolerance (%) or absolute mains supply
values ........................................................................ :

+10%, -10%

[x] OVC II

Tested for IT power systems .................................... :

[] Yes

IT testing, phase-phase voltage (V) .......................... :

N/A

Class of equipment ................................................... :

[x] Class I [] Class II
[] Not classified

Pollution degree (PD) ............................................... :

[] PD 1

IP protection class .................................................... :

IPX0

Altitude during operation (m) .................................... :

Up to 2000m

Altitude of test laboratory (m) .................................... :

Up to 2000m

Mass of equipment (kg) ………………………………..:

3.4kg

Maximum operation ambient …………………...……..:

50C

[] OVC III

[] OVC IV

[x] No

[x] PD 2

[] Class III

[] PD 3

Possible test case verdicts:
- Test case does not apply to the test object ………….:

N (Not Applicable)

- Test object does meet the requirement………………:

P (Pass)

- Test object does not meet the requirement………….:

F (Fail)

Testing:
Date of receipt of test item……………………………...:

N/A

Date of receipt of test sample ....................................... :

N/A

Status of test sample .................................................... :

N/A

Date(s) of performance of tests ………………………..:

N/A

General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(See Attachment #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Throughout this report, a point is used as the decimal separator.
List of test equipment must be kept on file and available for review.

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 4 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD

General product information:
1. The EUT is a 16-Port Gigabit Ethernet PoE+ Switch with 4 RJ45 Gigabit and 2 SFP Uplink Ports.
2. This amendment report shall be read in conjunction with original test report (ACSS1703016).
3. The updates concerned in this test report are as follows:
1). Revise applicant’s company name and address;
2). Revise manufacturer’s company name and address;
3). Revise product’s name and model;
4). The RJ45 ports 1-20 must be available, 21-24 can be optional.
4. After technical review, no test is necessary. All the test data were fully reproduced from original report
(ACSS1703016).
Report modify history
Report No. / issue date
No.
1
ACSS1703016/ April 6, 2017

Modification to the appliances:
Original test report

Additional information:
N/A
Attached enclosure(s):
Attachment A: 5 pages of Photo-Documentation.
Attachment B: 6 pages of Heatsink-Drawing.
Attachment C: 3 pages of Schematic and layout for power board.
Attachment D: 2 pages of Transformer T1 specification.
Attachment E: 2 pages of Transformer T2 specification.

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 5 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

1

GENERAL

P

1.5

Components

P

1.5.1

General

P

Comply with IEC 60950-1 or relevant component
standard

(See appended table 1.5.1)

P

1.5.2

Evaluation and testing of components

Certified components are
used in accordance with their
ratings, certifications and they
comply with applicable parts
of this standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 609501 and the relevant component
standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.

P

1.5.3

Thermal controls

Thermal controller (TH5) meet
the standard EN 60730-1.

P

1.5.4

Transformers

Comply with annex C

P

1.5.5

Interconnecting cables

Interconnection cables do not
present a hazard.

P

1.5.6

Capacitors bridging insulation

X2 capacitors and Y1
capacitors are used to be
according to IEC 60384-14.

P

1.5.7

Resistors bridging insulation

Refer to below:

P

1.5.7.1

Resistors bridging functional, basic or supplementary Bleeder resistors are bridging
insulation
function insulation.

P

1.5.7.2

Resistors bridging double or reinforced insulation
between a.c. mains and other circuits

N

1.5.7.3

Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable

N

1.5.8

Components in equipment for IT power systems

N

1.5.9

Surge suppressors

Approved surge suppressors.

P

1.5.9.1

General

Comply with annex Q

P

1.5.9.2

Protection of VDRs

A fuse is connected in series
with VDR.

P

1.5.9.3

Bridging of functional insulation by a VDR

Varistor(ZR1) located in line to
neutral after fuse(F1)

P

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 6 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

1.5.9.4

Bridging of basic insulation by a VDR

N

1.5.9.5

Bridging of supplementary, double or reinforced
insulation by a VDR

N

1.6

Power interface

P

1.6.1

AC power distribution systems

TN power systems.

P

1.6.2

Input current

(See appended table 1.6.2)

P

1.6.3

Voltage limit of hand-held equipment

This appliance is not handheld equipment.

N

1.6.4

Neutral conductor

P

1.7

Marking and instructions

P

1.7.1

Power rating

P

Rated voltage(s) or voltage range(s) (V) ................. :

Result - Remark

100-240V

Symbol for nature of supply, for d.c. only .............. :

Verdict

P
N

Rated frequency or rated frequency range (Hz) ... :

50/60Hz

P

Rated current (mA or A) ........................................ :

5A max

P

Manufacturer’s name or trade-mark or identification
mark ...................................................................... :

P

Model identification or type reference ................... :

561419

P

Symbol for Class II equipment only ......................... :

Class I equipment.

N

Other markings and symbols ................................... :

Other symbols do not affect
safety.

P

1.7.2

Safety instructions and marking

Refer to below:

P

1.7.2.1

General

1.7.2.2

Disconnect devices

Appliance inlet provided.

N

1.7.2.3

Overcurrent protective device

The unit is not pluggable
equipment type B or
permanently connected
equipment.

N

1.7.2.4

IT power distribution systems

1.7.2.5

Operator access with a tool

All areas containing hazard(s)
are inaccessible to the
operator.

N

1.7.2.6

Ozone

The equipment not containing
Ozone

N

1.7.3

Short duty cycles

The equipment is intended for
continuous operation.

N

1.7.4

Supply voltage adjustment ................................... :

No voltage selector.

N

Methods and means of adjustment; reference to
installation instructions ......................................... :

TRF No. SRENAV-01V1.4

P

N

N

Report No.: ACSS1811066
Page 7 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

1.7.5

Power outlets on the equipment .......................... :

No standard power outlet.

N

1.7.6

Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :

“T8AL/250V” near F1

P

1.7.7

Wiring terminals

Refer to below

P

1.7.7.1

Protective earthing and bonding terminals .......... :

Appliance inlet was used

P

1.7.7.2

Terminals for a.c. mains supply conductors

The equipment power
connection is detachable
power supply cord.

N

1.7.7.3

Terminals for d.c. mains supply conductors

1.7.8

Controls and indicators

See below:

P

1.7.8.1

Identification, location and marking ..................... :

The function of indicators
affecting safety is obvious
without knowledge of
language.

P

1.7.8.2

Colours ................................................................ :

Colors are used for functional
indications, not involved
safety.

P

1.7.8.3

Symbols according to IEC 60417 ........................ :

1.7.8.4

Markings using figures ....................................... :

No controls use figures.

N

1.7.9

Isolation of multiple power sources .................... :

Only one connection supplying
hazardous voltages and
energy levels to the
equipment.

N

1.7.10

Thermostats and other regulating devices ......... :

No thermostats or other
regulating devices.

N

1.7.11

Durability

The marking withstands
required tests.

P

1.7.12

Removable parts

No removable parts.

N

1.7.13

Replaceable batteries ......................................... :

No battery in the equipment.

N

N

N

Language(s) .........................................................:

—

Equipment for restricted access locations ........... :

2

PROTECTION FROM HAZARDS

P

2.1

Protection from electric shock and energy hazards

P

2.1.1

Protection in operator access areas

2.1.1.1

Access to energized parts
Test by inspection .................................................... :

TRF No. SRENAV-01V1.4

Equipment not intended for
installation in RAL.

N

1.7.14

No operator access to
energized parts.

P
P

Operator access areas are
protected from electric shock
and energy hazards

P

Report No.: ACSS1811066
Page 8 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Test with test finger (Figure 2A) ............................ :

Not touched to hazardous
parts

P

Test with test pin (Figure 2B) ................................ :

Not touched to hazardous
parts

P

Test with test probe (Figure 2C) ........................... :

No TNV circuits in the
equipment.

N

2.1.1.2

Battery compartments

No battery compartments.

N

2.1.1.3

Access to ELV wiring

No internal wiring at ELV
accessible to the operator.

N

Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)

Verdict

—

2.1.1.4

Access to hazardous voltage circuit wiring

No hazardous voltage wiring in
operator accessible area.

P

2.1.1.5

Energy hazards ........................................................ :

(see appended table 2.1.1.5)

P

2.1.1.6

Manual controls

No shafts of knobs etc.

N

2.1.1.7

Discharge of capacitors in equipment
Measured voltage (V); time-constant (s) .................. :

2.1.1.8

P
(see appended table 2.1.1.7)

—

Energy hazards – d.c. mains supply

N

a) Capacitor connected to the d.c. mains supply .... :

N

b) Internal battery connected to the d.c. mains supply
................................................................................... :

N

2.1.1.9

Audio amplifiers ........................................................ :

N

2.1.2

Protection in service access areas

No unexpected hazards inside
the unit and no unintentional
contact to hazardous areas
likely during service operations
as considering the equipment
disconnected from mains
when servicing.

P

2.1.3

Protection in restricted access locations

Equipment not intended for
installation in RAL.

N

2.2

SELV circuits

P

2.2.1

General requirements

P

2.2.2

Voltages under normal conditions (V) .................. :

(see appended table 2.2.2)

P

2.2.3

Voltages under fault conditions (V) ....................... :

(see appended table 2.2.3)

P

2.2.4

Connection of SELV circuits to other circuits ...... :

Connected to other SELV
circuits.

P

2.3

TNV circuits
No TNV circuit.

N

2.3.1

Limits

N

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 9 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

Type of TNV circuits .................................................. :

—

2.3.2

Separation from other circuits and from accessible
parts

N

2.3.2.1

General requirements

N

2.3.2.2

Protection by basic insulation

N

2.3.2.3

Protection by earthing

N

2.3.2.4

Protection by other constructions ......................... :

N

2.3.3

Separation from hazardous voltages

N

Insulation employed ............................................... :

—

Connection of TNV circuits to other circuits

N

Insulation employed ............................................... :

—

2.3.5

Test for operating voltages generated externally

N

2.4

Limited current circuits

P

2.4.1

General requirements

P

2.4.2

Limit values

2.3.4

(see appended table 2.4)

P

Frequency (Hz).......................................................... :

—

Measured current (mA) ............................................. :

—

Measured voltage (V) ................................................ :

—

Measured circuit capacitance (nF or µF) ............... :

—

2.4.3

Connection of limited current circuits to other
circuits

2.5

Limited power sources
a) Inherently limited output

Connected to SELV

P
(see appended table 2.5)

b) Impedance limited output
c) Regulating network limited output under normal
operating and single fault condition

P
N

(see appended table 2.5)

d) Overcurrent protective device limited output
Max. output voltage (V), max. output current (A),
max. apparent power (VA) ..................................... :

P

P
N

(see appended table 2.5)

—

Current rating of overcurrent protective device (A) .:

—

2.6

Provisions for earthing and bonding

P

2.6.1

Protective earthing

TRF No. SRENAV-01V1.4

Accessible conductive parts
are reliably connected to
protective earth.

P

Report No.: ACSS1811066
Page 10 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

2.6.2

Functional earthing

Secondary functional earthing
is separated to primary by
reinforced or double
insulation.

P

2.6.3

Protective earthing and protective bonding
conductors

See below

P

2.6.3.1

General

2.6.3.2

Size of protective earthing conductors

P
Power supply cord was not
provided
2

Rated current (A), cross-sectional area (mm ),
AWG ...................................................................... :
2.6.3.3

Verdict

—
Protective bonding conductor
which connects to inlet ground
pin. See cl. 2.6.3.4 for ground
continue test.

Size of protective bonding conductors

N

2

P

Rated current (A), cross-sectional area (mm ),
AWG ...................................................................... :

—

Protective current rating (A), cross-sectional area
2
(mm ), AWG ........................................................... :

—

2.6.3.4

Resistance of earthing conductors and their
terminations; resistance (), voltage drop (V), test
current (A), duration (min) ......................................... :

2.6.3.5

Colour of insulation.................................................... :

2.6.4

Terminals

2.6.4.1

General

2.6.4.2

Protective earthing and bonding terminals

The earthing terminal in the
appliance inlet is regarded as
the main protective earthing
terminal. The test of subclause 2.6.3.4 was performed
for protective bonding
conductor and their terminals.

P

Rated current (A), type, nominal thread diameter
(mm)........................................................................... :

The test of cl. 2.6.3.4 is
complied.



2.6.4.3

Separation of the protective earthing conductor
from protective bonding conductors

The equipment is provided
with an appliance inlet.

P

2.6.5

Integrity of protective earthing

See below

P

2.6.5.1

Interconnection of equipment

No interconnection of
equipment.

N

2.6.5.2

Components in protective earthing conductors and
protective bonding conductors

There are no switches or
overcurrent protective devices
in the protective earthing /
bonding conductor.

P

TRF No. SRENAV-01V1.4

(See appended table 2.6.3.4)

P

N
See below

P
P

Report No.: ACSS1811066
Page 11 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

2.6.5.3

Disconnection of protective earth

It is not possible to disconnect
protective earth without
disconnecting mains; an
appliance coupler will be used
as disconnect device.

P

2.6.5.4

Parts that can be removed by an operator

Appliance couplers provided
for the protective earthing
connection is made before
and broken after the
hazardous voltage. No other
operator removable parts.

P

2.6.5.5

Parts removed during servicing

Protective earthed parts
cannot be removed in a way
which impair safety.

P

2.6.5.6

Corrosion resistance

No risk of corrosion

P

2.6.5.7

Screws for protective bonding

Adequate connection of
protective bonding.

P

2.6.5.8

Reliance on telecommunication network or cable
distribution system

Neither TNV circuits nor cable
distribution system in the
equipment.

N

2.7

Overcurrent and earth fault protection in primary circuits

P

2.7.1

Basic requirements

P

Pluggable equipment type A
primary fuse is used for
protective device.

Instructions when protection relies on building
installation

Verdict

N

2.7.2

Faults not simulated in 5.3.7

Considered

P

2.7.3

Short-circuit backup protection

The building installation is
considered as providing shortcircuit backup protection.

P

2.7.4

Number and location of protective devices .............:

Number: 1
Location: line

P

2.7.5

Protection by several devices

N

2.7.6

Warning to service personnel ...................................:



2.8

Safety interlocks
No safety interlocks provided.

N

2.8.1

General principles

N

2.8.2

Protection requirements

N

2.8.3

Inadvertent reactivation

N

2.8.4

Fail-safe operation

N

2.8.5

Moving parts

N

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 12 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

2.8.6

Overriding

N

2.8.7

Switches, relays and their related circuits

N

2.8.7.1

Separation distances for contact gaps and their
related circuits (mm) ........................................... :



2.8.7.2

Overload test

N

2.8.7.3

Endurance test

N

2.8.7.4

Electric strength test

N

2.8.8

Mechanical actuators

N

2.9

Electrical insulation

P

2.9.1

Properties of insulating materials

Neither natural rubber,
materials containing
asbestos or hygroscopic
materials are used as
insulation. No driving belts or
couplings used.

P

2.9.2

Humidity conditioning

120Hours

P

Relative humidity (%), temperature (°C) ............... :

96% RH, 40 degree C.

—

2.9.3

Grade of insulation

Refer to cl.2.10 and
appended table 5.2

P

2.9.4

Separation from hazardous voltages

For metal enclosure, basic
insulation used; For output
terminals, double or
reinforced insulation used.

P

Method(s) used ..................................................... :

Method 1and method 2

—

2.10

Clearances, creepage distances and distances through insulation

P

2.10.1

General

P

2.10.1.1

Frequency .............................................................. :

Considered

—

2.10.1.2

Pollution degrees ................................................... :

2

—

2.10.1.3

Reduced values for functional insualtion

The function insulation
complied with clause 5.3.4C

P

2.10.1.4

Intervening unconnected conductive parts

P

2.10.1.5

Insulation with varying dimensions

N

2.10.1.6

Special separation requirements

N

2.10.1.7

Insulation in circuits generating starting pulses

N

2.10.2

Determination of working voltage

2.10.2.1

General

2.10.2.2

RMS working voltage

See appended table 2.10.2

P

2.10.2.3

Peak working voltage

See appended table 2.10.2

P

TRF No. SRENAV-01V1.4

See appended table 2.10.2

P
P

Report No.: ACSS1811066
Page 13 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

2.10.3

Clearances

2.10.3.1

General

Refer to below

P

2.10.3.2

Mains transient voltages

Considered

P

a) AC mains supply ............................................... :

Over voltage category II for
primary circuit and transient
voltage 2500Vpeak.

—

P

b) Earthed d.c. mains supplies .............................. :

—

c) Unearthed d.c. mains supplies .......................... :

—

d) Battery operation ............................................... :

—

2.10.3.3

Clearances in primary circuits

See appended table 2.10.3
and 2.10.4

P

2.10.3.4

Clearances in secondary circuits

Function insulation, meet
5.3.4 method c).

P

2.10.3.5

Clearances in circuits having starting pulses

The circuit will not generate
starting pulse.

N

2.10.3.6

Transients from a.c. mains supply ........................ :

—

2.10.3.7

Transients from d.c. mains supply ........................ :

—

2.10.3.8

Transients from telecommunication networks and
cable distribution systems ..................................... :

—

2.10.3.9

Measurement of transient voltage levels

N

a) Transients from a mains suplply

N

For an a.c. mains supply ....................................... :

—

For a d.c. mains supply ......................................... :

—

b) Transients from a telecommunication network :

N

2.10.4

Creepage distances

P

2.10.4.1

General

Refer to below:

P

2.10.4.2

Material group and comparative tracking index

Material group IIIb is
assumed.

P

CTI tests .................................................................... :

—

2.10.4.3

Minimum creepage distances

2.10.5

Solid insulation

P

2.10.5.1

General

P

2.10.5.2

Distances through insulation

See appended table 2.10.5

P

2.10.5.3

Insulating compound as solid insulation

See appended table 1.5.1

P

2.10.5.4

Semiconductor devices

See appended table 1.5.1

P

2.10.5.5

Cemented joints

N

2.10.5.6

Thin sheet material – General

P

TRF No. SRENAV-01V1.4

See appended table 2.10.3
and 2.10.4

P

Report No.: ACSS1811066
Page 14 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

2.10.5.7

Separable thin sheet material

Insulation tape used wrapped
on the transformer.

P

Number of layers (pcs) ........................................... :

2 layers as reinforced
insulation.

—

2.10.5.8

Non-separable thin sheet material

N

2.10.5.9

Thin sheet material – standard test procedure

N

Electric strength test

—

Thin sheet material – alternative test procedure

P

2.10.5.10

Electric strength test
2.10.5.11

Insulation in wound components

2.10.5.12

Wire in wound components

See appended table 5.2

N
Primary winding on the
transformer T2 in power
board was used triple
insulated wire.

—

a) Basic insulation not under stress ...................... :

—
Wire complies to Annex U,
three layers as reinforced
insulation.

c) Compliance with Annex U ................................. :
Two wires in contact inside wound component;
angle between 45 and 90 ................................... :

2.10.5.14

P

Working voltage ..................................................... :

b) Basic, supplemetary, reinforced insulation ....... :

2.10.5.13

—

—
—

Protection against
mechanical stress is provided
by tube and insulation tape.

—

Wire with solvent-based enamel in wound
components

N

Electric strength test

—

Routine test

N

Additional insulation in wound components

N

Working voltage ..................................................... :

—

- Basic insulation not under stress ........................ :

—

- Supplemetary, reinforced insulation .................... :

—

2.10.6

Construction of printed boards

Refer to below:

P

2.10.6.1

Uncoated printed boards

(See appended table 2.10.3
and 2.10.4)

P

2.10.6.2

Coated printed boards

N

2.10.6.3

Insulation between conductors on the same inner
surface of a printed board

N

2.10.6.4

Insulation between conductors on different layers of Refer to below
a printed board

P

Distance through insulation

P

TRF No. SRENAV-01V1.4

1.6mm

Report No.: ACSS1811066
Page 15 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Number of insulation layers (pcs)............................. :

1

—

2.10.7

Component external terminations

(See appended table 2.10.3
and 2.10.4)

P

2.10.8

Tests on coated printed boards and coated
components

N

2.10.8.1

Sample preparation and preliminary inspection

N

2.10.8.2

Thermal conditioning

N

2.10.8.3

Electric strength test

N

2.10.8.4

Abrasion resistance test

N

2.10.9

Thermal cycling

2.10.10

Test for Pollution Degree 1 environment and
insulating compound

N

2.10.11

Tests for semiconductor devices and cemented joints Optical isolators approved
See appended table 1.5.1

P

2.10.12

Enclosed and sealed parts

N

3

WIRING, CONNECTIONS AND SUPPLY

P

3.1

General

P

3.1.1

Current rating and overcurrent protection

Adequate cross sectional
areas on internal wiring.

P

3.1.2

Protection against mechanical damage

Wireways are smooth and
free from edges. Wires are
adequetely fixed to present
excessive strain on wire and
terminals and avoiding
damage to the insulation of
the conductors.

P

3.1.3

Securing of internal wiring

Wireways are smooth and
free from edges. Wires are
adequately fixed to prevent
excessive strain on wire and
terminals and avoiding
damage to the insulation of
the conductors.

P

3.1.4

Insulation of conductors

Insulation on terminal
conductors is considered to
be of adequate quality and
suitable for the application
and the working voltage
involved.

P

3.1.5

Beads and ceramic insulators

Not provided.

N

3.1.6

Screws for electrical contact pressure

At least two complete threads
into the metal plate.

P

TRF No. SRENAV-01V1.4

Optical isolators approved
See appended table 1.5.1

Verdict

P

Report No.: ACSS1811066
Page 16 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

3.1.7

Insulating materials in electrical connections

All connections are metal to
metal, or where contact
pressure is transmitted
through PCB material for
earthing purposes a
combination of screw.

P

3.1.8

Self-tapping and spaced thread screws

Not use self-tapping and
spaced thread screws

N

3.1.9

Termination of conductors

Terminations cannot become
displaced so that clearances
and creepage distances can
be reduced.

P

10 N pull test

Considered

P

3.1.10

Sleeving on wiring

Sleeving could not slip

P

3.2

Connection to a mains supply

3.2.1

Means of connection

3.2.1.1

Connection to an a.c. mains supply

3.2.1.2

Connection to a d.c. mains supply

The equipment is not for
connection to a d.c. mains
supply.

N

3.2.2

Multiple supply connections

Single phase supply.

N

3.2.3

Permanently connected equipment

Not permanently connected
equipment.

N

P
Appliance inlet

P
P



Number of conductors, diameter of cable and
conduits (mm) ........................................................:
3.2.4

Appliance inlets

The appliance inlet complies
with IEC 60320-1 and is
properly placed to avoid
hazards after insertion of the
appliance coupler.

P

3.2.5

Power supply cords

No power cord provided.

N

3.2.5.1

AC power supply cords

N

Type .......................................................................:

—

2

Rated current (A), cross-sectional area (mm ),
AWG ......................................................................:

—

3.2.5.2

DC power supply cords

Not connected to DC supply.

N

3.2.6

Cord anchorages and strain relief

Equipment provided with an
appliance inlet.

N

Mass of equipment (kg), pull (N) ..........................:

—

Longitudinal displacement (mm) ...........................:
3.2.7

Protection against mechanical damage

TRF No. SRENAV-01V1.4

No sharp points of cutting
edges on the equipment
surfaces.

—
P

Report No.: ACSS1811066
Page 17 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

3.2.8

Cord guards

N

Diameter or minor dimension D (mm); test mass (g)
................................................................................:

—

Radius of curvature of cord (mm) ...........................:

—

3.2.9

Supply wiring space

N

3.3

Wiring terminals for connection of external conductors

N

3.3.1

Wiring terminals

N

3.3.2

Connection of non-detachable power supply cords

N

3.3.3

Screw terminals

N

3.3.4

Conductor sizes to be connected

N

Rated current (A), cord/cable type, cross-sectional
2
area (mm ) ..............................................................:

—

Wiring terminal sizes

N

Rated current (A), type, nominal thread diameter
(mm) ......................................................................:

—

3.3.6

Wiring terminal design

N

3.3.7

Grouping of wiring terminals

N

3.3.8

Stranded wire

N

3.4

Disconnection from the mains supply

P

3.4.1

General requirement

P

3.4.2

Disconnect devices

3.4.3

Permanently connected equipment

N

3.4.4

Parts which remain energized

N

3.4.5

Switches in flexible cords

No such switches used.

N

3.4.6

Number of poles - single-phase and d.c. equipment

Disconnect device
disconnects all poles
simultaneously.

P

3.4.7

Number of poles - three-phase equipment

Single phase equipment.

N

3.4.8

Switches as disconnect devices

No such switches used.

N

3.4.9

Plugs as disconnect devices

The appliance coupler will be
regarded as disconnect
device, no warning is
required.

N

3.4.10

Interconnected equipment

No interconnection of
hazardous voltages or energy
levels.

N

3.4.11

Multiple power sources

One power source only.

N

3.3.5

TRF No. SRENAV-01V1.4

Result - Remark

No wiring terminals.

Appliance coupler

Verdict

P

Report No.: ACSS1811066
Page 18 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

3.5

Interconnection of equipment

3.5.1

General requirements

Considered.

P

3.5.2

Types of interconnection circuits ............................. :

SELV circuits.

P

3.5.3

ELV circuits as interconnection circuits

No ELV interconnection.

N

3.5.4

Data ports for additional equipment

(see appended table 2.5)

P

4

PHYSICAL REQUIREMENTS

P

4.1

Stability

N

P

Angle of 10

≤7kg

N

Test force (N) ........................................................ :

The unit is not floor-standing.

—

4.2

Mechanical strength

P

4.2.1

General

P

4.2.2

Steady force test, 10 N

4.2.3

Steady force test, 30 N

4.2.4

Steady force test, 250 N

No hazard. The test is
performed at top, bottom and
sides of metal enclosure.

P

4.2.5

Impact test

Carried out to top side,
lateral-sides and bottom side
of Enclosure.

P

Fall test

No hazard as result of the
impact test.

P

No hazard as a result of the
10N test.

P
N

Swing test

N

4.2.6

Drop test; height (mm) .......................................... :

N

4.2.7

Stress relief test

Metal enclosure.

N

4.2.8

Cathode ray tubes

No CRT provided.

N

Picture tube separately certified ........................... :

N

4.2.9

High pressure lamps

4.2.10

Wall or ceiling mounted equipment; force (N) ....... :

N

4.2.11

Rotating solid media

N

Test to cover on the door………………………….:

—

4.3

Design and construction

P

4.3.1

Edges and corners

TRF No. SRENAV-01V1.4

No high pressure lamp
provided.

All edges and corners are
rounded and/or smoothed.

N

P

Report No.: ACSS1811066
Page 19 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

4.3.2

Handles and manual controls; force (N) ............. :

No knobs, grips, handles,
lever etc.

N

4.3.3

Adjustable controls

No hazardous adjustable
controls.

N

4.3.4

Securing of parts

All hazardous parts are fixed
to retain position in event of
termination failure.

P

4.3.5

Connection by plugs and sockets

SELV connector does not
comply with IEC 60320 or
IEC 60083.

P

4.3.6

Direct plug-in equipment

Not direct plug-in equipment.

N

Torque .................................................................. :

—

Compliance with the relevant mains plug standard
.............................................................................. :

N

4.3.7

Heating elements in earthed equipment

No heating elements
provided.

N

4.3.8

Batteries

N

- Overcharging of a rechargeable battery

N

- Unintentional charging of a non-rechargeable
battery

N

- Reverse charging of a rechargeable battery

N

- Excessive discharging rate for any battery

N

4.3.9

Oil and grease

Insulation is not exposed to
oil, grease etc.

N

4.3.10

Dust, powders, liquids and gases

The equipment does not
contain flammable liquids or
gases.

N

4.3.11

Containers for liquids or gases

No containers for liquids or
gases in the equipment.

N

4.3.12

Flammable liquids ................................................ :

The equipment does not
contain flammable liquid.

N

Quantity of liquid (l) .............................................. :

N

Flash point (C) .................................................... :

N

4.3.13

Radiation

4.3.13.1

General

4.3.13.2

Ionizing radiation

See below

P
P

The equipment does not
generate ionizing radiation.

N

Measured radiation (pA/kg) .................................. :

—

Measured high-voltage (kV) ................................. :

—

Measured focus voltage (kV) ............................... :

—

CRT markings ...................................................... :

—

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 20 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause
4.3.13.3

Requirement + Test

Result - Remark

Effect of ultraviolet (UV) radiation on materials

The equipment does not
produce significant UV
radiation.

Part, property, retention after test, flammability
classification ......................................................... :

Verdict
N

N

4.3.13.4

Human exposure to ultraviolet (UV) radiation ...... :

The equipment does not
produce significant UV
radiation.

N

4.3.13.5

Lasers (including laser diodes) and LEDs

P

4.3.13.5.1

Lasers (including laser laser diodes)

N

Laser class ........................................................... :



4.3.13.5.2

Light emitting diodes (LEDs)

Diffusive LED only, the
energy of the indicator LED
is far below the limit for class
I LED products.

P

4.3.13.6

Other types .......................................................... :

The equipment does not
generate other types of
radiation.

N

4.4

Protection against hazardous moving parts

4.4.1

General

Approved DC fan.

P

4.4.2

Protection in operator access areas .................... :

P

4.4.3

Protection in restricted access locations .............. :

No possible to access the
DC fan blades through the
openings on right cover.
No such locations.

4.4.4

Protection in service access areas

4.4.5

Protection against moving fan blades

See below

P

4.4.5.1

General

m=0.008kg, r=20mm,
N=5500r/min
Complied. (See appended
table 4.4.5)

P

4.4.5.3

N
N

Not considered to cause pain or injury. a)………….:

4.4.5.2

P



Is considered to cause pain, not injury. b) …………:



Considered to cause injury.



c) …………:

Protection for users

N

Use of symbol or warning ……………………...……:



Protection for service persons

N

Use of symbol or warning ………………...…………:



4.5

Thermal requirements

P

4.5.1

General

P

4.5.2

Temperature tests

(See appended table 4.5.2)

Normal load condition per Annex L .........................:
4.5.3

Temperature limits for materials

TRF No. SRENAV-01V1.4

P
—

Not exceed the values.

P

Report No.: ACSS1811066
Page 21 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

4.5.4

Touch temperature limits

Not exceed the values.

P

4.5.5

Resistance to abnormal heat ............................... :

Complying.
(See appended table 1.5.1)

P

4.6

Openings in enclosures

P

4.6.1

Top and side openings

P

4.6.2

Verdict

Dimensions (mm) ................................................. :

See appended table
4.6.1,4.6.2

—

Bottoms of fire enclosures

No opening

P

Construction of the bottomm, dimensions (mm) ....:

—

4.6.3

Doors or covers in fire enclosures

N

4.6.4

Openings in transportable equipment

4.6.4.1

Constructional design measures

N

Dimensions (mm) ....................................................:

—

4.6.4.2

Evaluation measures for larger openings

N

4.6.4.3

Use of metallized parts

N

4.6.5

Adhesives for constructional purposes

Not transportable equipment

Adhesives not used.

N

N

Conditioning temperature (C), time (weeks)........ :

—

4.7

Resistance to fire

P

4.7.1

Reducing the risk of ignition and spread of flame

In accordance with method 1.

P

Method 1, selection and application of components
wiring and materials

Materials with the required
flammability classes are
used.

P

Method 2, application of all of simulated fault
condition tests

Method 1 used.

N

4.7.2

Conditions for a fire enclosure

Refer to below:

P

4.7.2.1

Parts requiring a fire enclosure

The fire enclosure is required
to cover all parts.

P

4.7.2.2

Parts not requiring a fire enclosure

The fire enclosure is required
to cover all parts.

N

4.7.3

Materials

Refer to below:

P

4.7.3.1

General

Components and material
have adequate flammability
classification.
(See appended table 1.5.1)

P

4.7.3.2

Materials for fire enclosures

Metallic

P

4.7.3.3

Materials for components and other parts outside
fire enclosures

Fire enclosures cover all
parts

N

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 22 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

4.7.3.4

Materials for components and other parts inside fire
enclosures

Internal components and
other parts inside fire
enclosure are rated min. V-2.

P

4.7.3.5

Materials for air filter assemblies

No air filters in the
equipment.

N

4.7.3.6

Materials used in high-voltage components

No high-voltage components.

N

5

ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS

P

5.1

Touch current and protective conductor current

P

5.1.1

General

Test conducted in
accordance with cl.5.1.2 to
cl.5.1.7

P

5.1.2

Configuration of equipment under test (EUT)

No interconnected equipment
or multiple power sources

N

5.1.2.1

Single connection to an a.c. mains supply

P

5.1.2.2

Redundant multiple connections to an a.c. mains
supply

N

5.1.2.3

Simultaneous multiple connections to an a.c. mains
supply

N

5.1.3

Test circuit

Figure 5A used

P

5.1.4

Application of measuring instrument

Measuring circuit in annex
D.1 used

P

5.1.5

Test procedure

5.1.6

Test measurements

See below

P

Supply voltage (V) ................................................ :

264Vac, 60Hz

—

Measured touch current (mA) .............................. :

See appended table 5.1.6

—

Max. allowed touch current (mA) ......................... :

Unearthed accessible parts:
0.25mA;
Earthed accessible parts:
3.5mA

—

P

Measured protective conductor current (mA) ...... :

—

Max. allowed protective conductor current (mA) .. :

—

5.1.7

Equipment with touch current exceeding 3,5 mA

5.1.7.1

General ................................................................ :

N

5.1.7.2

Simultaneous multiple connections to the supply

N

5.1.8

Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks

5.1.8.1

Limitation of the touch current to a
telecommunication network or to a cable distribution
system

TRF No. SRENAV-01V1.4

The touch current does not
exceed 3.5mA

Not connected to a
telecommunication network
or cable distribution systems

N

N

N

Report No.: ACSS1811066
Page 23 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

Supply voltage (V) ................................................ :

—

Measured touch current (mA) .............................. :

—

Max. allowed touch current (mA) ......................... :

—

Summation of touch currents from
telecommunication networks

N

a) EUT with earthed telecommunication ports ..... :

N

b) EUT whose telecommunication ports have no
reference to protective earth

N

5.2

Electric strength

P

5.2.1

General

5.2.2

Test procedure

P

5.3

Abnormal operating and fault conditions

P

5.3.1

Protection against overload and abnormal operation See appended table 5.3

P

5.3.2

Motors

See appended annex B

P

5.3.3

Transformers

See appended annex C

P

5.3.4

Functional insulation .............................................. :

Complies with method c).

P

5.3.5

Electromechanical components

No electromechanical
components in secondary
circuits.

N

5.3.6

Audio amplifiers in ITE ......................................... :

The equipment does not
contain audio amplifies.

N

5.3.7

Simulation of faults

(see appended table 5.3)

P

5.3.8

Unattended equipment

No thermostats, temperature
limiters or thermal cut-outs

N

5.3.9

Compliance criteria for abnormal operating and fault Refer to below:
conditions

P

5.3.9.1

During the tests

No fire propagated beyond
the equipment. No molten
metal was emitted. No any
hazard.

P

5.3.9.2

After the tests

Not reduction of clearance
and creepage distances.
Electric Strength tests
performed after abnormal
and fault tests.

P

6

CONNECTION TO TELECOMMUNICATION NETWORKS
The equipment is not connected to a TELECOMMUNICATION NETWORKS

N

6.1

Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment

N

5.1.8.2

TRF No. SRENAV-01V1.4

See appended table 5.2

P

Report No.: ACSS1811066
Page 24 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

6.1.1

Protection from hazardous voltages

N

6.1.2

Separation of the telecommunication network from earth

N

6.1.2.1

Requirements

N

Supply voltage (V) ................................................ :

—

Current in the test circuit (mA) ............................ :

—

6.1.2.2

Exclusions ............................................................ :

N

6.2

Protection of equipment users from overvoltages on telecommunication networks

N

6.2.1

Separation requirements

N

6.2.2

Electric strength test procedure

N

6.2.2.1

Impulse test

N

6.2.2.2

Steady-state test

N

6.2.2.3

Compliance criteria

N

6.3

Protection of the telecommunication wiring system from overheating

N

Max. Output current (A) ........................................ :

—

Current limiting method ........................................ :

—

7

CONNECTION TO CABLE DISTRIBUTION SYSTEMS
The equipment is not connected to a CABLE DISTRIBUTION SYSTEMS.

N

7.1

General

N

7.2

Protection of cable distribution system service
persons, and users of other equipment connected to
the system, from hazardous voltages in the
equipment

N

7.3

Protection of equipment users from overvoltages on
the cable distribution system

N

7.4

Insulation between primary circuits and cable
distribution systems

N

7.4.1

General

N

7.4.2

Voltage surge test

N

7.4.3

Impulse test

N

A

ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE

N

A.1

Flammability test for fire enclosures of movable
equipment having a total mass exceeding 18 kg, and
of stationary equipment (see 4.7.3.2)

N

A.1.1

Samples ................................................................ :

—

Wall thickness (mm) .............................................. :

—

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 25 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

A.1.2

Conditioning of samples; temperature (C) .......... :

N

A.1.3

Mounting of samples ............................................ :

N

A.1.4

Test flame (see IEC 60695-11-3)

N

Flame A, B, C or D ............................................... :

—

A.1.5

Test procedure

N

A.1.6

Compliance criteria

N

Sample 1 burning time (s) ..................................... :

—

Sample 2 burning time (s) ..................................... :

—

Sample 3 burning time (s) ..................................... :

—

A.2

Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)

N

A.2.1

Samples, material ................................................. :

—

Wall thickness (mm) .............................................. :

—

A.2.2

Conditioning of samples; temperature (°C) .......... :

N

A.2.3

Mounting of samples ............................................ :

N

A.2.4

Test flame (see IEC 60695-11-4)

N

Flame A, B or C .................................................... :

—

A.2.5

Test procedure

N

A.2.6

Compliance criteria

N

Sample 1 burning time (s) ..................................... :

—

Sample 2 burning time (s) ..................................... :

—

Sample 3 burning time (s) ..................................... :

—

Alternative test acc. to IEC 60695-11-5, cl. 5 and 9

N

Sample 1 burning time (s) ..................................... :
Sample 2 burning time (s) ..................................... :

—
—

Sample 3 burning time (s) ..................................... :

—

A.3

Hot flaming oil test (see 4.6.2)

N

A.3.1

Mounting of samples

N

A.3.2

Test procedure

N

A.3.3

Compliance criterion

N

B

ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and
5.3.2)

N

B.1

General requirements

N

Position ................................................................ :

—

Manufacturer ........................................................ :

—

Type ..................................................................... :

—

A.2.7

TRF No. SRENAV-01V1.4

Result - Remark

Verdict

Report No.: ACSS1811066
Page 26 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

Rated values ....................................................... :

—

B.2

Test conditions

N

B.3

Maximum temperatures

N

B.4

Running overload test

N

B.5

Locked-rotor overload test

N

Test duration (days) ............................................. :

—

Electric strength test: test voltage (V) .................. :

—

B.6

Running overload test for d.c. motors in secondary
circuits

N

B.6.1

General

N

B.6.2

Test procedure

N

B.6.3

Alternative test procedure

N

B.6.4

Electric strength test; test voltage (V) .................. :

N

B.7

Locked-rotor overload test for d.c. motors in
secondary circuits

N

B.7.1

General

N

B.7.2

Test procedure

N

B.7.3

Alternative test procedure

N

B.7.4

Electric strength test; test voltage (V) ................. :

N

B.8

Test for motors with capacitors

N

B.9

Test for three-phase motors

N

B.10

Test for series motors

N

Operating voltage (V) ........................................... :

—

ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)

P

C

Position ................................................................ :

See appended table 1.5.1

—

Manufacturer ........................................................ :

See appended table 1.5.1

—

Type ..................................................................... :

See appended table 1.5.1

—

Rated values ....................................................... :

See appended table 1.5.1

—

Method of protection ............................................. :

—

C.1

Overload test

See appended table 5.3

P

C.2

Insulation

See appended table 5.2
Fixed by insulation tape and
tube.

P

Protection from displacement of windings ............ :

P

D

ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
(see 5.1.4)

P

D.1

Measuring instrument

P

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 27 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

D.2

Alternative measuring instrument

N

E

ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)

N

F

ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10 and Annex G)

P

G

ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES

N

G.1

Clearances

N

G.1.1

General

G.1.2

Summary of the procedure for determining
minimum clearances

N
N

G.2

Determination of mains transient voltage (V)

N

G.2.1

AC mains supply .................................................. :

N

G.2.2

Earthed d.c. mains supplies ................................. :

N

G.2.3

Unearthed d.c. mains supplies ............................. :

N

G.2.4

Battery operation .................................................. :

N

G.3

Determination of telecommunication network
transient voltage (V) ............................................. :

N

G.4

Determination of required withstand voltage (V)

N

G.4.1

Mains transients and internal repetitive peaks ..... :

N

G.4.2

Transients from telecommunication networks ..... :

N

G.4.3

Combination of transients

N

G.4.4

Transients from cable distribution systems

N

G.5

Measurement of transient voltages (V)

N

a) Transients from a mains supply

N

For an a.c. mains supply

N

For a d.c. mains supply

N

b) Transients from a telecommunication network

N

G.6

Determination of minimum clearances ................ :

N

H

ANNEX H, IONIZING RADIATION (see 4.3.13)

N

J

ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)

N

Metal(s) used ....................................................... :

—

K

Result - Remark

ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)

TRF No. SRENAV-01V1.4

Verdict

N

Report No.: ACSS1811066
Page 28 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

K.1

Making and breaking capacity

N

K.2

Thermostat reliability; operating voltage (V) ......... :



K.3

Thermostat endurance test; operating voltage (V)
............................................................................... :



K.4

Temperature limiter endurance; operating voltage
(V) ......................................................................... :



K.5

Thermal cut-out reliability

N

K.6

Stability of operation

N

L

ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)

P

L.1

Typewriters

N

L.2

Adding machines and cash registers

N

L.3

Erasers

N

L.4

Pencil sharpeners

N

L.5

Duplicators and copy machines

N

L.6

Motor-operated files

N

L.7

Other business equipment

P

M

ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)

N

M.1

Introduction

N

M.2

Method A

N

M.3

Method B

N

M.3.1

Ringing signal

M.3.1.1

Frequency (Hz) .................................................... :

N
—

M.3.1.2

Voltage (V) ........................................................... :

—

M.3.1.3

Cadence; time (s), voltage (V) ............................. :

—

M.3.1.4

Single fault current (mA) ...................................... :

—

M.3.2

Tripping device and monitoring voltage ............... :

N

M.3.2.1

Conditions for use of a tripping device or a
monitoring voltage

N

M.3.2.2

Tripping device

N

M.3.2.3

Monitoring voltage (V) .......................................... :

—

N

ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1,
7.3.2, 7.4.3 and Clause G.5)

N

N.1

ITU-T impulse test generators

N

N.2

IEC 60065 impulse test generator

N

TRF No. SRENAV-01V1.4

Result - Remark

Verdict

Report No.: ACSS1811066
Page 29 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

P

ANNEX P, NORMATIVE REFERENCES

—

Q

ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)

P

a) Preferred climatic categories ........................... :

—

b) Maximum continuous voltage .......................... :

—

c) Pulse current .................................................... :

—

R

ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES

N

R.1

Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)

N

R.2

Reduced clearances (see 2.10.3)

N

S

ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)

N

S.1

Test equipment

N

S.2

Test procedure

N

S.3

Examples of waveforms during impulse testing

N

T

ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)

N

Not protected against ingress of water.

—

ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)

P

Triple insulation wire was used. (See appended table 1.5.1)

—

V

ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)

P

V.1

Introduction

P

V.2

TN power distribution systems

V.3

TT power distribution systems

N

V.4

IT power distribution systems

N

U

Result - Remark

Single-phase. TN power
system considered and used
for testing

Verdict

P

W

ANNEX W, SUMMATION OF TOUCH CURRENTS

N

W.1

Touch current from electronic circuits

N

W.1.1

Floating circuits

N

W.1.2

Earthed circuits

N

W.2

Interconnection of several equipments

N

W.2.1

Isolation

N

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 30 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

W.2.2

Common return, isolated from earth

N

W.2.3

Common return, connected to protective earth

N

X

ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS
(see clause C.1)

P

X.1

Determination of maximum input current

See annex C.1

P

X.2

Overload test procedure

Electronic protection mode is
used.

P

Y

ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)

N

Y.1

Test apparatus ..................................................... :

N

Y.2

Mounting of test samples ..................................... :

N

Y.3

Carbon-arc light-exposure apparatus ................... :

N

Y.4

Xenon-arc light exposure apparatus .................... :

N

Z

ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)

N

AA

ANNEX AA, MANDREL TEST (see 2.10.5.8)

N

BB

ANNEX BB, CHANGES IN THE SECOND EDITION

—

CC

ANNEX CC, Evaluation of integrated circuit (IC) current limiters

N

CC.1

General

N

CC.2

Test program 1…………………………………….:

—

CC.3

Test program 2…………………………………….:

—

DD

ANNEX DD, Requirements for the mounting means of rack-mounted
equipment

N

DD.1

General

N

DD.2

Mechanical strength test, variable N…………..:

—

DD.3

Mechanical strength test, 250N, including end
stops…………………………………………………:

—

DD.4

Compliance…………………………………………:

—

EE

ANNEX EE, Household and home/office document/media shredders

N

EE.1

General

N

EE.2

Markings and instructions

N

Use of markings or symbols………….…………:

—

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 31 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

Information of user instructions, maintenance
and/or servicing instructions……………………:

—

EE.3

Inadvertent reactivation test………………….…:

—

EE.4

Disconnection of power to hazardous moving parts:

N

Use of markings or symbols……………………:

—

Protection against hazardous moving parts

N

Test with test finger (Figure 2A) ………...……:

—

Test with wedge probe (Figure EE1 and EE2) :

—

EE.5

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 32 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 – CENELEC COMMON MODIFICATIONS
Clause

Contents

(A2:2013)

General

General
(A1:2010)

General
(A2:2013)

1.1.1
(A1:2010)

Requirement + Test

Result - Remark

Verdict

Clauses, subclauses, notes, tables and figures which are additional to those in
IEC60950-1 and it´s amendmets are prefixed “Z”

—

Add the following annexes:
Annex ZA (normative)

—

European
Annex ZB (normative)
Annex ZD (informative)

Normative references to international
publications with their corresponding
publications
Special national conditions
IEC and CENELEC code designations for
flexible cords

Delete all the “country” notes in the reference document (IEC 60950-1:2005)
according to the following list:
1.4.8
Note 2
1.5.1
Note 2 & 3
1.5.7.1
Note
1.5.8
Note 2
1.5.9.4
Note
1.7.2.1
Note 4, 5 & 6
2.2.3
Note
2.2.4
Note
2.3.2
Note
2.3.2.1 Note 2
2.3.4
Note 2
2.6.3.3
Note 2 & 3
2.7.1
Note
2.10.3.2
Note 2
2.10.5.13 Note 3
3.2.1.1 Note
3.2.4
Note 3.
5.1
Note 2
4.3.6
Note 1 & 2
4.7
Note 4
4.7.2.2
Note
4.7.3.1 Note 2
5.1.7.1
Note 3 & 4
5.3.7
Note 1
6
Note 2 & 5
6.1.2.1
Note 2
6.1.2.2
Note
6.2.2
Note
6.2.2.1
Note 2
6.2.2.2
Note
7.1
Note 3
7.2
Note
7.3
Note 1 & 2
G.2.1 Note 2
Annex H
Note 2
Delete all the “country” notes in the reference document (IEC 609501:2005/A1:2010) according to the following list:
1.5.7.1 Note
6.1.2.1 Note 2
6.2.2.1 Note 2
EE.3
Note

—

Delete all the “country” notes in the reference document (IEC 609501:2005/A2:2013) according to the following list:
2.7.1
Note *
2.10.3.1
Note 2
6.2.2.
Note
* Note of secretary: Text of Common Modification remains unchanged.
Replace the text of NOTE 3 by the following.

—

NOTE 3 The requirements of EN 60065 may also be used to meet safety requirements for multimedia
equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. For television sets EN
60065 applies.

TRF No. SRENAV-01V1.4

—

N

Report No.: ACSS1811066
Page 33 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

1.3.Z1

Add the following subclause:
1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and constructed
as to present no danger when used for its intended
purpose, either in normal operating conditions or
under fault conditions, particularly providing
protection against exposure to excessive sound
pressures from headphones or earphones.

Result - Remark

Verdict
N

NOTE Z1 A new method of measurement is described in
EN 50332-1, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part
1: General method for “one package equipment”, and in
EN 50332-2, Sound system equipment: Headphones and
earphones associated with portable audio equipment Maximum sound pressure level measurement
methodology and limit considerations - Part 2: Guidelines
to associate sets with headphones coming from different
manufacturers.
(A12:2011)

In EN 60950-1:2006/A12:2011
Delete the addition of 1.3.Z1 / EN 60950-1:2006
Delete the definition 1.2.3.Z1 / EN 60950-1:2006
/A1:2010

N

1.5.1

Add the following NOTE:

N

(Added
info*)

NOTE Z1 The use of certain substances in electrical and
electronic equipment is restricted within the EU: see
Directive 2002/95/EC.
New Directive 2011/65/11 *

1.7.2.1
(A1:2010)

1.7.2.1
(A12.2011)

In addition, for a PORTABLE SOUND SYSTEM, the
instructions shall include a warning that excessive
sound pressure from earphones and headphones can
cause hearing loss.
In EN 60950-1:2006/A12:2011
Delete NOTE Z1 and the addition for Portable Sound
System.
Add the following clause and annex to the existing
standard and amendments.

N

Zx Protection against excessive sound pressure from personal music
players

N

TRF No. SRENAV-01V1.4

N

Report No.: ACSS1811066
Page 34 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Not personal music player
Zx.1 General
This sub-clause specifies requirements for protection
against excessive sound pressure from personal
music players that are closely coupled to the ear. It
also specifies requirements for earphones and
headphones intended for use with personal music
players.

Verdict
N

A personal music player is a portable equipment
for personal use, that:
is designed to allow the user to listen to recorded
or broadcast sound or video; and
primarily uses headphones or earphones that can
be worn in or on or around the ears; and
allows the user to walk around while in use.
NOTE 1 Examples are hand-held or body-worn portable CD
players, MP3 audio players, mobile phones with MP3 type
features, PDA’s or similar equipment.

A personal music player and earphones or
headphones intended to be used with personal
music players shall comply with the requirements of
this sub-clause.
The requirements in this sub-clause are valid for
music or video mode only.
The requirements do not apply:
while the personal music player is connected to an
external amplifier; or
while the headphones or earphones are not used.
NOTE 2 An external amplifier is an amplifier which is not part of
the personal music player or the listening device, but which is
intended to play the music as a standalone music player.

The requirements do not apply to:
hearing aid equipment and professional equipment;
NOTE 3 Professional equipment is equipment sold through
special sales channels. All products sold through normal
electronics stores are considered not to be professional
equipment.

analogue personal music players (personal music
players without any kind of digital processing of the
sound signal) that are brought to the market before
the end of 2015.
NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that within a few
years it will no longer exist. This exemption will not be extended to
other technologies.

For equipment which is clearly designed or intended
for use by young children, the limits of EN 71-1
apply.

TRF No. SRENAV-01V1.4

N

Report No.: ACSS1811066
Page 35 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test
Zx.2 Equipment requirements
No safety provision is required for equipment that
complies with the following:
 equipment provided as a package (personal music
player with its listening device), where
the acoustic output LAeq,T is ≤ 85 dBA measured
while playing the fixed “programme simulation noise”
as described in EN 50332-1; and
a personal music player provided with an
analogue electrical output socket for a listening
device, where the electrical output is ≤ 27 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise” as
described in EN 50332-1.
NOTE 1 Wherever the term acoustic output is used in this clause,
the 30 s A-weighted equivalent sound pressure level LAeq,T is
meant. See also Zx.5 and Annex Zx.

All other equipment shall:
a) protect the user from unintentional acoustic
outputs exceeding those mentioned above; and
b) have a standard acoustic output level not
exceeding those mentioned above, and
automatically return to an output level not
exceeding those mentioned above when the
power is switched off; and
c) provide a means to actively inform the user of the
increased sound pressure when the equipment is
operated with an acoustic output exceeding those
mentioned above. Any means used shall be
acknowledged by the user before activating a
mode of operation which allows for an acoustic
output exceeding those mentioned above. The
acknowledgement does not need to be repeated
more than once every 20 h of cumulative listening
time; and
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening time,
independent how often and how long the personal music player
has been switched off.

d) have a warning as specified in Zx.3; and
e) not exceed the following:
1) equipment provided as a package (player with
Its listening device), the acoustic output shall be ≤
100 dBA measured while playing the fixed
“programme simulation noise” described in EN
50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device, the electrical output shall be ≤ 150 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
described in EN 50332-1.

TRF No. SRENAV-01V1.4

Result - Remark

Verdict
N

Report No.: ACSS1811066
Page 36 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

For music where the average sound pressure (long
term LAeq,T) measured over the duration of the song
is lower than the average produced by the
programme simulation noise, the warning does not
need to be given as long as the average sound
pressure of the song is below the basic limit of 85
dBA. In this case T becomes the duration of the
song.

Verdict
N

NOTE 4 Classical music typically has an average sound pressure
(long term LAeq,T) which is much lower than the average
programme simulation noise. Therefore, if the player is capable to
analyse the song and compare it with the programme simulation
noise, the warning does not need to be given as long as the
average sound pressure of the song is below the basic limit of 85
dBA.
For example, if the player is set with the programme simulation
noise to 85 dBA, but the average music level of the song is only
65 dBA, there is no need to give a warning or ask an
acknowledgement as long as the average sound level of the song
is not above the basic limit of 85 dBA.

Zx.3 Warning
The warning shall be placed on the equipment, or on
the packaging, or in the instruction manual and shall
consist of the following:
the symbol of Figure 1 with a minimum height of 5
mm; and
the following wording, or similar:

N

“To prevent possible hearing damage, do not listen
at high volume levels for long periods.”
/
Figure 1 – Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given
through the equipment display during use, when the
user is asked to acknowledge activation of the higher
level.
Zx.4 Requirements for listening devices (headphones and earphones)

N

Zx.4.1 Wired listening devices with analogue
input
With 94 dBA sound pressure output LAeq,T, the input
voltage of the fixed “programme simulation noise”
described in EN 50332-2 shall be ≥ 75 mV.

N

This requirement is applicable in any mode where
the headphones can operate (active or
passive), including any available setting (for example
built-in volume level control).
NOTE The values of 94 dBA – 75 mV correspond with 85dBA –
27 mV and 100 dBA – 150 mV.

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 37 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test
Zx.4.2 Wired listening devices with digital input
With any playing device playing the fixed
“programme simulation noise” described in EN
50332-1 (and respecting the digital interface
standards, where a digital interface standard exists
that specifies the equivalent acoustic level), the
acoustic output LAeq,T of the listening device shall be
≤ 100 dBA.

Result - Remark

Verdict
N

This requirement is applicable in any mode where
the headphones can operate, including any available
setting (for example built-in volume level control,
additional sound feature like equalization, etc.).
NOTE An example of a wired listening device with digital input is a
USB headphone.

Zx.4.3 Wireless listening devices
In wireless mode:
with any playing and transmitting device playing
the fixed programme simulation noise described in
EN 50332-1; and
respecting the wireless transmission standards,
where an air interface standard exists that specifies
the equivalent acoustic level; and
with volume and sound settings in the listening
device (for example built-in volume level control,
additional sound feature like equalization, etc.) set to
the combination of positions that maximize the
measured acoustic output for the abovementioned
programme simulation noise, the acoustic output
LAeq,T of the listening device shall be ≤ 100 dBA.

N

NOTE An example of a wireless listening device is a Bluetooth
headphone.

Zx.5 Measurement methods
Measurements shall be made in accordance with EN
50332-1 or EN 50332-2 as applicable. Unless stated
otherwise, the time interval T shall be 30 s.

N

NOTE Test method for wireless equipment provided without
listening device should be defined.

2.7.1

Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-circuits
and earth faults in PRIMARY CIRCUITS, protective
devices shall be included either as integral parts of
the equipment or as parts of the building installation,
subject to the following, a), b) and c):
a) except as detailed in b) and c), protective devices
necessary to comply with the requirements of 5.3
shall be included as parts of the equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and
earth fault protection may be provided by
protective devices in the building installation;

TRF No. SRENAV-01V1.4

P

Report No.: ACSS1811066
Page 38 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

N

2.7.2

c) it is permitted for PLUGGABLE EQUIPMENT
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent
and short-circuit protection in the building
installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fully
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so state,
except that for PLUGGABLE EQUIPMENT TYPE A
the building installation shall be regarded as
providing protection in accordance with the rating of
the wall socket outlet.
This subclause has been declared ‘void’.

3.2.3

Delete the NOTE in Table 3A, and delete also in this
table the conduit sizes in parentheses.

N

3.2.5.1

Replace

“60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or
H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or
H05 VVH2-F2”.
In Table 3B, replace the first four lines by the
following:
a)
Up to and including 6 |
0,75 |
b)
Over 6 up to and including 10| (0,75)
1,0 |
c)
Over 10 up to and including 16| (1,0)
1,5
|
In the conditions applicable to Table 3B delete the
a)
words “in some countries” in condition .
In NOTE 1, applicable to Table 3B, delete the
second sentence.

N

3.2.5.1

NOTE Z1 The harmonized code designations corresponding to
the IEC cord types are given in Annex ZD

N

3.3.4

In Table 3D, delete the fourth line: conductor sizes
for 10 to 13 A, and replace with the following:
Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to 4
|
Delete the fifth line: conductor sizes for 13 to 16 A

N

4.3.13.6

Replace the existing NOTE by the following:

N

(A2:2013)

(A1:2010)

Result - Remark

Verdict

N

NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the limitation
of exposure of the general public to electromagnetic fields
0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and safety
requirements regarding the exposure of workers to risks
arising from physical agents (artifical optical radiation).
Standards taking into account mentioned
Recommendation and Directive which demonstrate
compliance with the applicable EU Directive are indicated
in the OJEC.

TRF No. SRENAV-01V1.4

N

Report No.: ACSS1811066
Page 39 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Annex H

Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall not
exceed 1 μSv/h (0,1 mR/h) (see NOTE). Account is
taken of the background level.
Replace the notes as follows:

Verdict
N

NOTE These values appear in Directive 96/29/Euratom.

Delete NOTE 2.
Bibliograp Additional EN standards.
hy



ZA



NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR
CORRESPONDING EUROPEAN PUBLICATIONS
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)

Clause

Requirement + Test

1.2.4.1

In Denmark, certain types of Class I appliances (see
3.2.1.1) may be provided with a plug not establishing
earthing conditions when inserted into Danish
socket-outlets.
In Norway and Sweden, for requirements see
1.7.2.1 and 7.3 of this annex.
In Finland, Norway and Sweden, resistors bridging
BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT
TYPE A must comply with the requirements in 1.5.7.1.
In addition when a single resistor is used, the
resistor must withstand the resistor test in 1.5.7.2.
In Norway, due to the IT power system used (see
annex V, Figure V.7), capacitors are required to be
rated for the applicable line-to-line voltage (230 V).
In Finland, Norway and Sweden, the third dashed
No such construction.
sentence is applicable only to equipment as defined
in 6.1.2.2 of this annex.
In Finland, Norway and Sweden, CLASS I
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be
as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”

1.2.13.14
(A11:2009)

1.5.7.1
(A11:2009)

1.5.8

1.5.9.4
1.7.2.1

TRF No. SRENAV-01V1.4

Result - Remark

Verdict

N

N
N

P
N
N

Report No.: ACSS1811066
Page 40 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

1.7.2.1

In Norway and Sweden, the screen of the cable
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of a
cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what country
the equipment is intended to be used in:
“Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in some
circumstances create a fire hazard. Connection to a
cable distribution system has therefore to be
provided through a device providing electrical
isolation below a certain frequency range (galvanic
isolator, see EN 60728-11).”

N

NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, for
1 min.

N

(A11:2009)

Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved tilkopling
av utstyret til kabel-TV nettet installeres en galvanisk
isolator mellom utstyret og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV nät
kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”

TRF No. SRENAV-01V1.4

Result - Remark

Verdict

Report No.: ACSS1811066
Page 41 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

1.7.2.1

In Denmark, CLASS I PLUGGABLE EQUIPMENT
TYPE A intended for connection to other equipment
or a network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in Denmark shall be as follows:
In Denmark: “Apparatets stikprop skal tilsluttes en
stikkontakt med jord, som giver forbindelse til
stikproppens jord.”
In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when
used on Class I equipment. For STATIONARY
EQUIPMENT the socket-outlet shall be in
accordance with Standard Sheet DK 1-1b or DK 15a.

N

For CLASS II EQUIPMENT the socket outlet shall be in
accordance with Standard Sheet DKA 1-4a.
In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the DS
60884-2-D1:2011.
For class I equipment the following Standard Sheets
are applicable: DK 1-3a, DK 1-1c,
DK 1-1d, DK 1-5a or DK 1-7a, with the exception for
STATIONARY EQUIPMENT where the socketoutlets shall be in accordance with Standard Sheet
DK 1-1b, DK 1-1c, DK 1-1d or DK 1-5a.
Socket outlets intended for providing power to Class
II apparatus with a rated current of 2,5 A shall be in
accordance with DS 60884-2-D1 standard sheet
DKA 1-4a. Other current rating socket outlets shall
be in compliance with by DS 60884-2-D1 Standard
Sheet DKA 1-3a or DKA 1-3b.
Justification
the Heavy Current Regulations, 6c
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and
6.1.2.2 of this annex.
In Finland, Norway and Sweden there are
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and
6.1.2.2 of this annex.
In the United Kingdom, the current rating of the
circuit shall be taken as 13 A, not 16 A.
In the United Kingdom, to protect against excessive
currents and short-circuits in the PRIMARY CIRCUIT
of DIRECT PLUG-IN EQUIPMENT, tests according
to 5.3 shall be conducted, using an external
protective device rated 30 A or 32 A. If these tests
fail, suitable protective devices shall be included as
integral parts of the DIRECT PLUG-IN EQUIPMENT,
so that the requirements of 5.3 are met.

N

(A2:2013)

1.7.5

1.7.5
(A11:2009)

1.7.5
(A2:2013)

2.2.4
2.3.2
2.3.4
2.6.3.3
2.7.1

TRF No. SRENAV-01V1.4

Result - Remark

Verdict

N

N

N
N
N
N
N

Report No.: ACSS1811066
Page 42 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

2.10.5.13

In Finland, Norway and Sweden, there are
additional requirements for the insulation, see
6.1.2.1 and 6.1.2.2 of this annex.
In Switzerland, supply cords of equipment having a
RATED CURRENT not exceeding 10 A shall be
provided with a plug complying with SEV 1011 or
IEC 60884-1 and one of the following dimension
sheets:
SEV 6532-2.1991 Plug Type 15, 3P+N+PE, 250/400
V, 10 A
SEV 6533-2.1991 Plug Type 11, L+N, 250 V, 10 A
SEV 6534-2.1991 Plug Type 12, L+N+PE, 250 V,
10A
In general, EN 60309 applies for plugs for currents
exceeding 10 A. However, a 16 A plug and socketoutlet system is being introduced in Switzerland, the
plugs of which are according to the following
dimension sheets, published in February 1998:
SEV 5932-2.1998: Plug Type 25 , 3L+N+PE 230/400
V, 16 A

3.2.1.1

Result - Remark

Verdict
N
N

SEV 5933-2.1998:Plug Type 21, L+N, 250 V, 16A
SEV 5934-2.1998: Plug Type 23, L+N+PE 250 V, 16
A

3.2.1.1

In Denmark, supply cords of single-phase
equipment having a rated current not exceeding13 A
shall be provided with a plug according to the Heavy
Current Regulations, Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT exceeding
13 A is provided with a supply cord with a plug, this
plug shall be in accordance with the Heavy Current
Regulations, Section 107-2-D1 or EN 60309-2.

TRF No. SRENAV-01V1.4

N

Report No.: ACSS1811066
Page 43 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

3.2.1.1

In Denmark, supply cords of single-phase
equipment having a rated current not exceeding 13
A shall be provided with a plug according to DS
60884-2-D1.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a poly-phase
equipment is provided with a supply cord with a plug,
this plug shall be in accordance with the standard
sheets DK 6-1a in DS 60884-2-D1 or EN 60309-2.
Justification
the Heavy Current Regulations, 6c

N

3.2.1.1

In Spain, supply cords of single-phase equipment
having a rated current not exceeding 10 A shall be
provided with a plug according to UNE 20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be provided
with a plug according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules, shall be
provided with a plug in accordance with standard
UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.

N

3.2.1.1

In the United Kingdom, apparatus which is fitted
with a flexible cable or cord and is designed to be
connected to a mains socket conforming to BS 1363
by means of that flexible cable or cord and plug,
shall be fitted with a ‘standard plug’ in accordance
with Statutory Instrument 1768:1994 - The Plugs and
Sockets etc. (Safety) Regulations 1994, unless
exempted by those regulations.

N

(A2:2013)

Result - Remark

Verdict

NOTE ‘Standard plug’ is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS
1363 or an approved conversion plug.

3.2.1.1

In Ireland, apparatus which is fitted with a flexible
cable or cord and is designed to be connected to a
mains socket conforming to I.S. 411 by means of
that flexible cable or cord and plug, shall be fitted
with a 13 A plug in accordance with Statutory
Instrument 525:1997 - National Standards Authority
of Ireland (section 28) (13 A Plugs and Conversion
Adaptors for Domestic Use) Regulations 1997.

N

3.2.4

In Switzerland, for requirements see 3.2.1.1 of this
annex.

N

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 44 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

3.2.5.1

In the United Kingdom, a power supply cord with
conductor of 1,25 mm2 is allowed for equipment with
a rated current over 10 A and up to and including 13
A.

N

3.3.4

In the United Kingdom, the range of conductor
sizes of flexible cords to be accepted by terminals for
equipment with a RATED CURRENT of over 10 A up
to and including 13 A is:
2
2
• 1,25 mm to 1,5 mm nominal cross-sectional area.

N

4.3.6

In the United Kingdom, the torque test is performed
using a socket outlet complying with BS 1363 part
1:1995, including Amendment 1:1997 and
Amendment 2:2003 and the plug part of DIRECT
PLUG-IN EQUIPMENT shall be assessed to BS
1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12,
12.13, 12.16 and 12.17, except that the test of 12.17
is performed at not less than 125 °C. Where the
metal earth pin is replaced by an Insulated Shutter
Opening Device (ISOD), the requirements of clauses
22.2 and 23 also apply.

N

4.3.6

In Ireland, DIRECT PLUG-IN EQUIPMENT is known
as plug similar devices. Such devices shall comply
with Statutory Instrument 526:1997 - National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and sockets for
domestic use) Regulations, 1997.

N

5.1.7.1

In Finland, Norway and Sweden TOUCH
CURRENT measurement results exceeding 3,5 mA
r.m.s. are permitted only for the following equipment:
• STATIONARY PLUGGABLE EQUIPMENT TYPE
A that is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential bonding
has been applied, for example, in a
telecommunication centre; and has provision for a
permanently connected PROTECTIVE EARTHING
CONDUCTOR; and is provided with instructions for
the installation of that conductor by a SERVICE
PERSON;
• STATIONARY PLUGGABLE EQUIPMENT TYPE
B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.

N

TRF No. SRENAV-01V1.4

Result - Remark

Verdict

Report No.: ACSS1811066
Page 45 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

6.1.2.1

In Finland, Norway and Sweden, add the following
text between the first and second paragraph of the
compliance clause:
If this insulation is solid, including insulation forming
part of a component, it shall at least consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of at
least 0,4 mm, which shall pass the electric strength
test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and in
addition
- passes the tests and inspection criteria of 2.10.11
with an electric strength test of 1,5 kV multiplied by
1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.

N

It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).

N

(A1:2010)

It is permitted to bridge this insulation with a
capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to EN 6038414:2005, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by having
a capacitor classified Y3 as defined by EN 6038414, which in addition to the Y3 testing, is tested with
an impulse test of 2,5 kV defined in EN 609501:2006, 6.2.2.1;
- the additional testing shall be performed on all the
test specimens as described in EN 60384-14:
- the impulse test of 2,5 kV is to be performed before
the endurance test in EN 60384-14, in the
sequence of tests as described in EN 60384-14.

TRF No. SRENAV-01V1.4

Result - Remark

Verdict

Report No.: ACSS1811066
Page 46 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

6.1.2.2

In Finland, Norway and Sweden, the exclusions are
applicable for PERMANENTLY CONNECTED
EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B
and equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has provision
for a permanently connected PROTECTIVE
EARTHING CONDUCTOR and is provided with
instructions for the installation of that conductor by a
SERVICE PERSON.

N

7.2

In Finland, Norway and Sweden, for requirements
see 6.1.2.1 and 6.1.2.2 of this annex.
The term TELECOMMUNICATION NETWORK in
6.1.2 being replaced by the term CABLE
DISTRIBUTION SYSTEM.

N

7.3

In Norway and Sweden, for requirements see
1.2.13.14 and 1.7.2.1 of this annex.

N

(A11:2009)

TRF No. SRENAV-01V1.4

Result - Remark

Verdict

Report No.: ACSS1811066
Page 47 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

Annex ZD
(informative)
IEC and CENELEC code designations for flexible cords
Type of flexible cord
Code designations
IEC
CENELEC
PVC insulated cords
Flat twin tinsel cord
60227 IEC 41
H03VH-Y
Light polyvinyl chloride sheathed flexible cord
60227 IEC 52
H03VV-F
H03VVH2-F
Ordinary polyvinyl chloride sheathed flexible cord
60277 IEC 53
H05VV-F
H05VVH2-F
Rubber insulated cords
Braided cord
60245 IEC 51
H03RT-F
Ordinary tough rubber sheathed flexible cord
60245 IEC 53
H05RR-F
Ordinary polychloroprene sheathed flexible cord
60245 IEC 57
H05RN-F
Heavy polychloroprene sheathed flexible cord
60245 IEC 66
H07RN-F
Cords having high flexibility
Rubber insulated and sheathed cord
60245 IEC 86
H03RR-H
Rubber insulated, crosslinked PVC sheathed cord
60245 IEC 87
H03RV4-H
Crosslinked PVC insulated and sheathed cord
60245 IEC 88
H03V4V4-H

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 48 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
1.5.1

TABLE: list of critical components

P

object/part No. manufacturer/
trademark

type/model

technical data

PCB

Interchangeable

Interchangeable

V-0, Min. 130C UL 796

UL

Metal
enclosure

Interchangeable

Interchangeable

Min. 1.0mm

--

--

AC inlet
(CON1)

Zhe Jiang Bei Er
Jia Electronic
Co., Ltd.
TECX-UNIONS
TECHNOLOGY
CORP
Dongguan Better
Electronics
Technology Co.,
Ltd.
Dongguan
Hongda
Electronic
Technology Co.,
Ltd.
Zhongshan
Lanbao Electrical
Appliances Co.,
Ltd.
Suzhou Littelfuse
OVS Ltd.
XC Electronics
(Shen Zhen)
Corp. Ltd.
DONGGUAN
QUANTAI
INDUSTRIAL CO
LTD
CHANGYUAN
ELECTRONICS
(SHENZHEN)
CO LTD
DONG GUAN
HUANG FENG
INSULATION
MATERIAL CO
LTD
DONGGUAN
GINO PLASTIC
PRODUCTS CO
LTD
Joyin Co., Ltd.

ST-A01-001L

AC 250V ,10A

EN60320-1

VDE
40013388

TU-301-AL

AC 250V ,10A

EN60320-1

522

T8AL, AC250V

IEC/EN 60127-1
IEC/EN 60127-3

ENEC00647-A1
UL E220004
VDE
40019022

52FD
52FDP

T8AL, AC250V

IEC/EN
60127-1 VDE
IEC/EN 60127-3
40034179

RTI-20

T8AL, AC250V

IEC/EN 60127-1
IEC/EN 60127-3

VDE
40012120

218-series

T8AL, AC250V

5F-Series

T8AL, AC250V

IEC/EN 60127-1
IEC/EN 60127-3
IEC/EN 60127-1
IEC/EN 60127-3

VDE
40013496
VDE
40009609

T-2

VW-1, 600V,
125°C

UL224

UL E227336

CB-HFT,
CB-HFT(XY),
CYG-MT

VW-1, 600V,
125°C

UL224

UL E180908

HFT-2

VW-1, 600V,
125°C

UL224

UL E236485

GINO S-901-600

600V 125

UL224

UL E472166

14N471K
14N821K

Min. AC 300V,
Min. 85C
Min. 3000A
Min. AC 300V,
Min. 85C
Min. 3000A

IEC/EN 61051-1
IEC/EN 61051-2
IEC/EN 61051-2-2
IEC/EN 61051-1
IEC/EN 61051-2
IEC/EN 61051-2-2

VDE 005937

(Alternative)
Fuse F1

(Alternative)

(Alternative)

(Alternative)
(Alternative)
Heat
shrinkable
Tube used on
F1
(Alternative)

(Alternative)

(Alternative)

Varistor (ZR1)
(optional)

(Alternative) Joyin Co., Ltd.

TRF No. SRENAV-01V1.4

10S471K
10S821K
14S471K
14S821K

standard

mark(s) of
1
conformity )

VDE
40004658

Report No.: ACSS1811066
Page 49 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
(Alternative) JYA-NAY Co.,
Ltd.
(Alternative) Centra Science
Corp.
(Alternative) Shantou HighNew Technology
Dev. Zone
Songtian
Enterprise Co.,
Ltd.
(Alternative) Lien Shun
Electronics Co.,
Ltd.
(Alternative) Success
Electronics Co.,
Ltd.
Y1-cap:
(CY4, CY5)
(optional)

Dongguan Easygather
Electronic Co.,
Ltd.

(Alternative) Haohua
Electronic Co.,

10D471K
10D821K
14D471K
14D821K
CNR-14D471K
CNR-14D821K

Min. AC 300V,
Min. 105C
Min. 3000A

IEC/EN 61051-1
IEC/EN 61051-2
IEC/EN 61051-2-2

VDE
40023949

Min. AC 300V,
Min. 105C
Min. 3000A
Min. AC 300V,
Min. 105C
Min. 3000A

IEC/EN 61051-1
IEC/EN 61051-2
IEC/EN 61051-2-2
IEC/EN 61051-1
IEC/EN 61051-2
IEC/EN 61051-2-2

VDE
40008220

Min. AC 300V,
Min. 105C
Min. 3000A

IEC/EN 61051-1
IEC/EN 61051-2
IEC/EN 61051-2-2

VDE
40005858

Min. AC 300V,
Min. 105C
Min. 3000A

IEC/EN 61051-1
IEC/EN 61051-2
IEC/EN 61051-2-2

VDE
40030401

Max.2200pF.
Min AC 400
Vac, 125°C,
subclass Y1

IEC 60384-14

VDE
40022942

Max.2200pF.
Min AC 400
Vac, 125°C,
subclass Y1
Max.2200pF.
Min AC 250
Vac, 125°C,
subclass Y1
Max.2200pF.
Min AC 250
Vac, 125°C,
subclass Y1

IEC 60384-14

VDE
40003902

IEC 60384-14

VDE
40016157

IEC 60384-14

VDE
40025754

F

Max.2200pF.
Min AC 250
Vac, 125°C,
subclass Y1

IEC 60384-14

VDE
40036393

CY

Max.2200pF.
Min AC 400
Vac, 125°C,
subclass Y1
Max.2200pF.
AC 400 Vac,
125°C,
subclass Y1
Max.2200pF.
Min AC 250
Vac, 125°C,
subclass Y1

IEC 60384-14

VDE
40008912

EN 60384-14

TUV
R50232059

IEC 60384-14

VDE
40020001
VDE
40020002

14D471K
14D821K

10D471K
10D821K
14D471K
14D821K
SVR10D471K
SVR10D821K
SVR14D471K
SVR14D821K
DCF

CT7

(Alternative) Welson Industrial WD
Co., Ltd.
(Alternative) Shantou HighNew Technology
Dev. Zone
Songtian
Enterprise Co.,
Ltd.
(Alternative) GUANGDONG
SOUTH
HONGMING
ELECTRONIC
SCIENCE &
TECHNOLOGY
CO LTD
(Alternative) Hsuan Tai
Electronic Co.
Ltd.

CD-Series

(Alternative) JYA-NAY Co.,
Ltd.

JN

(Alternative) Success
Electronics Co.,
Ltd.

SB
SE

TRF No. SRENAV-01V1.4

VDE
40023049

Report No.: ACSS1811066
Page 50 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
(Alternative) Shenzhen
Teruixiang
Electronic Co.,
Ltd.
(Alternative) DongGuan City
Jiankun
Electronics
Technology Co.
Ltd
(Alternative) Kunshan Micro
Capacitors
Electronic Co.,
Ltd.
(Alternative) Yinan Don's
Electronic
Component Co.,
Ltd.
Y2-cap:
Dongguan Easy(CY1, CY2)
gather
(optional)
Electronic Co.,
Ltd.
(Alternative) HAOHUA
ELECTRONIC
CO

TY-Series

JT-Series

B-Series,
E-Series
CT81

DCF

CT7

(Alternative) Hongzhi
Enterprises Ltd.

Y

(Alternative) Jyh Chung
Electronic Co.,
Ltd.

JY

(Alternative) JYA-NAY Co.,Ltd JY

(Alternative) Shantou HighNew Technology
Dev. Zone
Songtian
Enterprise Co.,
Ltd.
(Alternative) Kunshan Micro
Capacitors
Electronic Co.,
Ltd.
(Alternative) Hsuan Tai
Electronic Co.
Ltd.
(Alternative) DongGuan City
Jiankun
Electronics
Technology Co.
Ltd
X-cap:
Dain Electronics
(CX1, CX2,
Co., Ltd.
CX3)
(optional)
TRF No. SRENAV-01V1.4

CE Series

F-Series

CY

JK series

MPX

Max.2200pF.
Min AC 400
Vac, 125°C,
subclass Y1
Max.2200pF.
Min AC 250
Vac, 125°C,
subclass Y1

IEC 60384-14

VDE
40031733

IEC 60384-14

VDE
40041534

Max.2200pF.
Min AC 250
Vac, 125°C,
subclass Y1
Max.2200pF.
Min AC 250
Vac, 125°C,
subclass Y1
Max.1000pF.
Min AC 250
Vac, 125°C,
subclass Y2
Max.1000pF.
Min AC 250
Vac, 125°C,
subclass Y2
Max.1000pF.
Min AC 250
Vac, 125°C,
subclass Y2
Max.1000pF.
Min AC 300
Vac, 125°C,
subclass Y2
Max.1000pF.
Min AC 250
Vac, 125°C,
subclass Y2
Max.1000pF.
Min AC 250
Vac, 125°C,
subclass Y2

IEC 60384-14

VDE
40016537

IEC 60384-14

VDE
135256

UL 60384-14

UL
E252221

IEC 60384-14

VDE
40013601

IEC 60384-14

VDE
40038461

IEC 60384-14

VDE
123326

IEC 60384-14

TUV
R50232061

IEC 60384-14

VDE
40025748

Max.1000pF.
Min AC 250
Vac, 125°C,
subclass Y2
Max.1000pF.
Min AC 250
Vac, 125°C,
subclass Y2
Max.1000pF.
Min AC 250
Vac, 125°C,
subclass Y2

IEC 60384-14

VDE
40016130

IEC 60384-14

VDE
118413

IEC 60384-14

VDE
40041536

AC 275 Vac;
Max.0.47uF;
Min.100°C,
subclass X2

EN 60384-14

VDE
40018798

Report No.: ACSS1811066
Page 51 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
(Alternative) Carli Electronics
Co., Ltd.

MPX

(Alternative) Dongguan Easygather
Electronic Co.,
Ltd.
(Alternative) Joey Electronics
(Dong Guan)
Co., Ltd.

MKP

(Alternative) Hongzhi
Enterprises Ltd.

MPX

(Alternative) SHANTOU
HIGH-NEW
TECHNOLOGY
DEVELOPMNT
ZONE
SONGTIAN
ENTERPRISE
CO LTD
(Alternative) Shenzhen Su
Rong Capacitors
Co., Ltd.

MPX

(Alternative) Xiamen
Wanming
Electronics Co.,
Ltd.
(Alternative) SURETOP
TECHNOLOGY
Co. Ltd.

WPX/ MPX/
HQX/ UTX

(Alternative) Jenn Fu
Electronics
Corporation

MPX

MPX

MKP/MPX

MPX

(Alternative) ACEWIN Electric MEX
Industrial
Co. Ltd.

AC 275 Vac;
Max.0.47uF;
Min.100°C,
subclass X2
AC 300 Vac;
Max.0.47uF;
Min.105°C,
subclass X2
AC 275 Vac;
Max.0.47uF;
Min.105°C,
subclass X2
AC 275 Vac;
Max.0.47uF;
Min.100°C,
subclass X2
AC 275 Vac;
Max.0.47uF;
Min.85°C,
subclass X2

EN 60384-14

VDE
40008520

EN 60384-14

VDE
40022258

EN 60384-14

VDE
40032481

EN 60384-14

VDE
40023936

EN 60384-14

TUV R
50136379

AC 280 Vac;
Max.0.47uF;
Min.100°C,
subclass X2
AC 275 Vac;
Max.0.47uF;
Min.110°C,
subclass X2
AC 275 Vac;
Max.0.47uF;
Min.105°C,
subclass X2
AC 275 Vac;
Max.0.47uF;
Min.110°C,
subclass X2
AC 275 Vac;
Max.0.47uF;
Min.100°C,
subclass X2
1M ohm, 1/4W

EN 60384-14

VDE
40008924

EN 60384-14

VDE
40023119

EN 60384-14

VDE
40034508

EN 60384-14

VDE
40023085

EN 60384-14

VDE
40008614

EN 60950-1

Test with
appliance

Resistor(R17,
R17A, R18,
R18A)

Interchangeable

Interchangeable

Electrolytic
capacitor
(C11)
DB1 Bridge
diode
Line Filter
(LF1)

Interchangeable

Interchangeable

330uFmax;
450V,105

--

Test with
appliance

Interchangeable

Interchangeable

Min600V; Min
6A
Min105°C

--

Test with
appliance
Test with
appliance

Dongguanshi
PuHang
Electronic
Co.,Ltd.
-Magnet wire Interchangeable
-Core --

TRF No. SRENAV-01V1.4

T14*9*5C

Interchangeable
--

Copper wire,
min130°C
Ferrite

--

UL1446

UL

--

--

Report No.: ACSS1811066
Page 52 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
-Triple wire GREAT leoflon
industrial co ltd
-Varnish Interchangeable

TRW(B)
Interchangeable

Copper wire,
Min.130C
Minimum
130°C.

UL2353

UL E211989

UL1446

UL

Min105°C

--

Test with
appliance

Copper wire,
min130°C
Ferrite
Copper wire,
Min.130C
Minimum
130°C.
Min105°C

UL1446

UL

-UL2353

-UL E242198

UL1446

UL

--

Test with
appliance

Copper wire,
min130°C
Ferrite

UL1446

UL

--

--

PBT, V-0,
130°C
Minimum
130°C.

UL 94

UL

UL1446

UL

Min105°C

--

Test with
appliance

Copper wire,
min130°C
Ferrite

UL1446

UL

--

--

UL 94

UL

UL1446

UL

--

--

IEC 60747-5-5:
2011

VDE
40008087

IEC 60747-5-5:
2011

VDE 132249

EN 60747-5-5 :
2011

VDE
40007240

- Alt. Line Filter
(LF1)

Dongguan Ju
T14*9*5C
Rong Electronics
Co., Ltd.
-Magnet wire Interchangeable Interchangeable
-Core --Triple wire Young Chang
Silicone Co., Ltd
-Varnish Interchangeable

Line Filter
(LF2, LF3)

Dongguanshi
PuHang
Electronic
Co.,Ltd.
-Magnet wire Interchangeable
-Core --

-STW-B
Interchangeable
T25*15*10C

Interchangeable
--

-Clapboard Interchangeable

Interchangeable

-Varnish Interchangeable

Interchangeable

- Alt. Dongguan Ju
T20*12*8C
Rong Electronics
Co., Ltd.
-Magnet wire Interchangeable Interchangeable

Line Filter
(LF2, LF3)

-Core --

--

-Clapboard Interchangeable

Interchangeable

-Varnish Interchangeable

Interchangeable

Q1, Q2, Q4,
Q5, Q6

Interchangeable

Optocoupler
(OP1, OP2,
OP3)

SHARP CORP
ELECTRONIC
COMPONENTS
AND DEVICES
GROUP
(Alternative) Everlight
Electronics Co.,
Ltd.

Interchangeable

PC817/PC123

EL817

(Alternative) Bright Led
BPC817
Electronics Corp.

TRF No. SRENAV-01V1.4

PBT, V-0,
130°C
Minimum
130°C.
Min500V. Q1,
Q2, Q4, Q5 is
min10A, Q6 is
min2A
double
isolation,
100C, dTi
measured>0.4
mm minimum
double
isolation,
100C, dTi
measured>0.4
mm minimum
double
isolation,
100C, dTi
measured>0.4
mm minimum

Report No.: ACSS1811066
Page 53 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
(Alternative) Lite-On
Technology
Corporation

LTV-817

(Alternative) COSMO
Electronics
Corporation

C1010

(Alternative) COSMO
Electronics
Corporation

KPC817

(Alternative) China Resources PC817
Semiconductor
(ShenZhen) Ltd.
(Alternative) Fairchild
Semiconductor
Pte Ltd

H11A817

Transformer SHENZHEN
(T1) FORD
ELECTRONIC
CO LTD

GQ330W-T-1A

-Wire Interchangeable
-Bobbin CHANG CHUN
PLASTICS
CO.,LTD

Interchangeable
T200NA,

-Insulation JINGJIANG
Tape YAHUA
PRESSURE
SENSITIVE
GLUE CO LTD
-Varnish Interchangeable

Interchangeable

-Tube Interchangeable

Interchangeable

Transformer SHENZHEN
(T2) FORD
ELECTRONIC
CO LTD
-Bobbin Chang chun
plastics Co Ltd
-Insulation JINGJIANG
Tape YAHUA
PRESSURE
SENSITIVE
GLUE CO LTD
-Varnish Interchangeable
TRF No. SRENAV-01V1.4

PZ, CT

GQ330W-LLCT1
T200NA,

CT280

Interchangeable

double
isolation,
100C, dTi
measured>0.4
mm minimum
double
isolation,
100C, dTi
measured>0.4
mm minimum
double
isolation,
100C, dTi
measured>0.4
mm minimum
double
isolation,
100C, dTi
measured>0.4
mm minimum
double
isolation,
100C, dTi
measured>0.4
mm minimum
Class B

EN 60747-5-5:
2011

VDE
40015248

EN 60747-5-5:
2011

VDE
40010469

EN 60747-5-5:
2011

VDE 101347

EN 60747-5-5:
2011

VDE
40039266

EN 60747-5-5:
2011

VDE
40026857

EN 60950-1

Tested with
appliance

Copper wire,
Min.130°C.
Phenolic, V-0,
Min.150°C
thickness:
0.8mm
Polyethy lene
tercphthalate
film tape.
Min.130°C

UL1446

UL

UL94
UL746C

UL
E59481

UL510

UL E165111

Minimum
130°C.
Minimum
150°C.
Class B

UL1446

UL

UL 224

UL

EN 60950-1

Tested with
appliance

Phenolic, V-0,
UL94
Min.150°C
thickness:
0.8mm
Flame retardant UL510
film insulating
tape.
Min.130°C

UL E59481

Minimum
130°C.

UL

UL1446

UL E165111

Report No.: ACSS1811066
Page 54 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
-Triple SHENZHEN
insulated wire KAIZHONG
HEDONG NEW
MATERIAL CO
LTD
-Wire Interchangeable

TIW- B

Triple insulated UL2353
wire, Min.130C

UL E357240

Interchangeable

UL1446

UL

-Tube Interchangeable

Interchangeable

Copper wire,
Min.130°C.
Minimum
150°C.
Min.130C

UL 224

UL

EN 60950-1

Tested with
appliance

Copper wire,
Min.130°C.
Min.130°C.

UL1446

UL

UL1446

UL

T200NA

Phenolic, V-0,
Min.150°C

UL94
UL746C

UL
(E59481)

CT-280

Min.130°C

UL510

UL
(E165111)

Interchangeable

Min.150 °C,
VW-1
Min.130C

UL 224

UL

EN 60950-1

Tested with
appliance

Copper wire,
Min.130°C.
Min.130°C.

UL1446

UL

UL1446

UL

T200NA

Phenolic, V-0,
Min.150°C

UL94
UL746C

UL
(E59481)

CT-280

Min.130°C

UL510

UL
(E165111)

Interchangeable

Min.150 °C,
VW-1
V-0, 125C.
Min.thickness
0.25mm

UL 224

UL

UL 94

UL

Inductance
(L21)

SHENZHEN
FORD
ELECTRONIC
CO LTD
-Wire Interchangeable

Interchangeable

-varnish Interchangeable

Interchangeable

-bobbin CHANG CHUN
PLASTICS
CO.,LTD
-insulation JINGJIANG
tape YAHUA
PRESSURE
SENSITIVE
GLUE CO LTD
-tube Interchangeable
Inductance
(T3)

GQ330W-LLCT2

SHENZHEN
FORD
ELECTRONIC
CO LTD
-Wire Interchangeable

Interchangeable

-varnish Interchangeable

Interchangeable

-bobbin CHANG CHUN
PLASTICS
CO.,LTD
-insulation JINGJIANG
tape YAHUA
PRESSURE
SENSITIVE
GLUE CO LTD
-tube Interchangeable
Insulation
sheet
Between plug
pin and PCB
trace

Interchangeable

TRF No. SRENAV-01V1.4

GQ330W-PFCT1

Interchangeable

Report No.: ACSS1811066
Page 55 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
DC fan (two
provide)

DONGGUAN
YIN HAI
PLASTIC
ELECTRONICS
CO.,LTD

YH4020L05LCF50N

Heat
shrinkable
tubing for
Internal Wiring
Thermal
controller
(TH5)

SHENZHEN
RSFR-H
WOLIDA
TRADING CO
LTD
Changzhou
KW-***
Ainuo Electronics
Technical Co.,
Ltd.
Heatsink(HS1) --Heatsink(HS2) --

--

Heatsink(HS3) --

--

Heatsink(HS4) --

--

Heatsink(HS5) --

--

Heatsink(HS6) --

--

Heatsink for
-U3 on the
mainboard
Heatsink for
-U7 and U8 on
the mainboard

--

supplementary information:--

TRF No. SRENAV-01V1.4

--

DC5V, 0.13A

EN 60950-1:
2006/A2:2013

CE by
Shenzhen
Tian Hai test
technology
Co.,Ltd
(Report No.:
TH16FR392S.
Certificate
No.:
TH16FR392S.)
UL
E329530

Min.125 °C,
0.4mm. Rated
VW-1.

UL 224

250Vac,
0~165°C

EN 60730-1,
EN 60730-2

VDE
40030067

Metal, see
attachment B
for details
Metal, see
attachment B
for details
Metal, see
attachment B
for details
Metal, see
attachment B
for details
Metal, see
attachment B
for details
Metal, see
attachment B
for details
Metal, 34.6mm
x 35.0mm x
20mm
Metal, 28.0mm
x 28.0mm x
11.0mm

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

Report No.: ACSS1811066
Page 56 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
1.7.11

TABLE: Marking durability test

Marking type

Checked by

stick on EUT
printed on EUT
molded on EUT

P
Duration

Result

Water

15s

Curling:

Yes

No; Legibility:

Yes

No

Petroleum spirit

15s

Curling:

Yes

No; Legibility:

Yes

No

Note(s): --

1.6.2

TABLE: Input test

P

Fuse #

Irated (A)

U (V)

F (Hz)

I (A)

P (W)

Condition/status

F1

--

90

50/60

3.632/3.631

325.29/325.21

Max normal load

F1

5.0

100

50/60

3.237/3.229

322.83/322.79

Max normal load

F1

5.0

240

50/60

1.323/1.334

307.30/307.23

Max normal load

F1

--

264

50/60

1.254/1.260

306.54/306.44

Max normal load

Note(s): The measured steady input current at rated supply voltage shall not exceed the rated current by
more than 10% under normal load.
Max. normal load: All the output ports pull load to maximum rating.

TABLE: Max. V, A, VA measurement

2.1.1.5

P

Output tested

Output current
(rated) (A)

Voltage (max.)
(V)

Current (max.)
(A)

VA (max.)
(VA)

POE port #1
55Vdc

--

53.64

0.221

11.69

HAZ/EL
(Yes / No )
Yes

No

Note(s): Input voltage: 264 V/ 60 Hz
Output which exceeds 240 VA is considered to be at hazardous energy level (HAZ/EL).

2.1.1.7

Location Condition
L-N

P

TABLE: Discharge test

Standby

V peak

37% V peak

V peak at tc

370

136.9

705ms

Comment
Pluggable equipment type A

Note(s):
Input voltage: 264 V/ 60 Hz; X capacitor: X capacitor: CX1= CX2= CX3=0.47uF,
discharge resistor(s): R17=R17A=R18=R18A=1M ohm
The voltage at the external point of disconnection shall decay to less than 37% of its original value in
1.0 second.

2.2.2

P

TABLE: Hazardous voltage measurement

Component

Location

Max. voltage (V)
(normal operation)
V peak

V d.c.

Voltage Limiting
Components

T1

Pin 5– GND

26.6

--

--

T2

Pin 7–GND

5.3

--

--

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 57 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Pin 9–GND

55

--

--

Pin 10–GND

55

--

--

After D6

--

55.8

D7

After D7

--

55.8

D8

Note(s):
Input voltage:

2.2.3

264

V/ 60 Hz

P

TABLE: SELV reliability test

Accessible Part Component
From - To

Fault

Comment

Max. voltage (V)
(fault condition)
V peak

V d.c.

After D7 -GND

D7

S/C

--

0

Shutdown

After D8 -GND

D8

S/C

--

0

Shutdown

Note(s):
Input voltage:

2.4

264

V/ 60 Hz

P

TABLE: Limited current circuits test

Location

Voltage
(V)

Current
(mA)

Freq.
(kHz)

Limit
(mA)

CY4 secondary Pin to “GND”

3.56

1.78

64.7

45.29

CY5 secondary Pin to “GND”

4.82

2.41

64.1

44.87

Note(s):
Input voltage:

264

V/ 60 Hz; Y Capacitor: CY4=CY5=2200pF

2.5

TABLE: Limited power sources test

Output
tested

Location

P

Single fault

From

To

POE ports
#1

Pins(3,6)

Pin (7,8)

POE ports
#1

Pins(3,6)

POE ports
#1

Measured Maximum

Limited

Uoc (V)

Isc (A)

VA

Isc (A)

VA

Normal

53.64

0.221

11.69

2.79

100

Pin (7,8)

D7 S/C

53.66

0.221

11.69

2.79

100

Pins(3,6)

Pin (7,8)

J7 (1-7)
S/C

0

0

0

8

100

RJ45 ports

All pins

GND

Normal

0

0

0

8

100

SFP ports

Pins
(15,16)

GND

Normal

3.30

0

0

8

100

Note(s):
Input voltage:

2.6.3.4
Test point
between

264

V/ 60 Hz

TABLE: Earthing test
Current (A)

TRF No. SRENAV-01V1.4

Duration (min) Measured resistance or
voltage drops (ohms or V)

P
Limited resistance or
voltage drops (ohms or V)

Report No.: ACSS1811066
Page 58 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
AC inlet earth pin
to furthest metal
enclosure

32

2

0.003 ohms

0.1ohms

AC inlet earth pin
to CY1 secondary
pin

32

2

0.003 ohms

0.1ohms

AC inlet earth pin
to CY2 secondary
pin

32

2

0.004 ohms

0.1ohms

Note(s):--

2.9.2

P

TABLE: Humidity conditioning test

Test condition
20-30°C at 90-96% R.H. for 48h
40±2°C at 90-96%R.H. for 120h (tropical)

Actural condition

After humidity conditioning

40°C at 96% R.H. for
120h

Unit DID
breakdown

DID NOT no

See table 5.2
Note(s):

2.10.2

TABLE: Working voltage measurement

Component

Location
From
Pin 1

Pin 3
T1

Peak Voltage (Vac)

RMS Voltage (Vac) Comments

To
Pin 6, 7

200

117

--

Pin 8, 9

158

117

--

Pin 6, 7

250

124

--

Pin 8, 9

241

124

--

Pin 6, 7

550

162

*

Pin 8, 9

533

155

--

Pin 6, 7

191

117

--

Pin 8, 9

200

117

--

Pin 7

250

154

--

Pin 8, 9

283

157

--

Pin 10, 11

300

168

--

Pin 12

283

163

--

Pin 7

400

214

--

Pin 8, 9

458

251

*

Pin 10, 11

358

189

--

Pin 12

416

213

--

Pin 4

Pin 5

Pin 1

T2

Pin 5

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 59 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD

Pin 1
OP1
Pin 2

Pin 1
OP2
Pin 2

Pin 1
OP3
Pin 2

Pin 3

300

145

--

Pin 4

300

144

--

Pin 3

300

145

--

Pin 4

300

145

--

Pin 3

275

139

--

Pin 4

275

140

--

Pin 3

275

139

--

Pin 4

275

139

--

Pin 3

241

172

--

Pin 4

241

171

--

Pin 3

241

172

--

Pin 4

241

171

--

CY1

Pri

Sec

350

240

--

CY2

Pri

Sec

350

240

--

CY4

Pri

Sec

200

121

--

CY5

Pri

Sec

287

140

--

Note(s): Input: 240 V/ 60 Hz.
The * indicate the maximum Peak voltage or RMS voltage.
2.10.3 and
2.10.4

TABLE: Clearances and creepage distances measurement

Rated supply voltage:

100-240V

Location

Pollution degree:
Operating Voltage

2

P
Material Group:

Clearance (mm)

Creepage (mm)

IIIb
CTI

V peak

V rms

Min

Actual

Min

Actual

--

Between primary and protective earth
near ac inlet, as basic

<420

<250

2.0

3.3

2.5

3.3

< 175

Opposite pattern traces before fuse
(F1) on PCB, as basic

<420

<250

2.0

3.6

2.5

3.6

< 175

Primary fuse (F1), pattern traces on
PCB, as basic

<420

<250

2.0

4.5

2.5

4.5

< 175

Pattern traces, between Primary and
Secondary (OP3) on PCB, as
reinforced

<420

<250

4.0

6.7

5.0

6.7

< 175

Pattern traces, between Primary and
Secondary (CY4) on PCB, as
reinforced

<420

<250

4.0

7.5

5.0

7.5

< 175

Between primary and secondary (T1)
on traces side, as reinforced

550

240

4.4

7.5

4.8

7.5

< 175

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 60 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Between primary and secondary (T1),
as reinforced
Between primary and core(T1), as
basic
Between secondary and core (T1), as
basic
Between primary and secondary (T2)
on traces side, as reinforced
Between primary and secondary (T2),
as reinforced
Between primary and core(T2), as
reinforced

550

240

4.4

7.5

4.8

7.5

< 175

550

240

2.2

3.9

2.4

3.9

< 175

550

240

2.2

3.9

2.4

3.9

< 175

458

251

4.0

20.9

4.8

20.9

< 175

458

251

4.0

10.8

4.8

10.8

< 175

458

251

2.0

12.8

2.4

14.1

< 175

Note(s):
B=Basic insulation, D/R= double insulation or reinforce insulation.
- No components reduce distance after 10N steady force applied.
- One Mylar sheet is cover power board both sides to isolate metal enclosure.
- T2 primary wire used triple insulation wire, core as secondary.

TABLE: Distance through insulation measurement

2.10.5

P

U peak
(V)

U rms
(V)

Test
voltage (V)

1. Insulation tape wrapped on transformer (T1),
Reinforced, 2 layers (one layer tested)

550

240

3000Vac

At least 2
layers

2layers

2. Insulation tape wrapped on transformer (T2),
Reinforced, 2 layers (one layers tested)

458

251

3000Vac

At least 2
layers

2layers

3. Mylar sheet (for power board)

550

240

1820Vac

--

0.25mm

4. Heat shrinkable tubing for Internal Wiring

550

240

3000Vac

--

0.40mm

Distance through insulation (DTI) at/of:

Required
dti
(mm)

dti
(mm)

Note(s):--

4.2.2,
TABLE: Steady force test
4.2.3, 4.2.4

P

Location

Force

duration

Components

10N±1N

5s

Location

Force

duration

--

30N±1N

--

Location

Force

duration

Metal enclosure

250N±10N

5s

Result
Unit
Unit

DID
DID

DID NOT show damage
DID NOT breakdown
Result

Unit
Unit

DID
DID

DID NOT show damage
DID NOT breakdown
Result

Unit

DID

DID NOT show damage

Unit

DID

DID NOT breakdown

Note(s): --

4.2.5

TABLE: Impact test

TRF No. SRENAV-01V1.4

P

Report No.: ACSS1811066
Page 61 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Location

Vertical distance

Metal enclosure outside, top and
sides of power supply

Result
Unit
Unit

1.3 m

DID
DID

DID NOT show damage
DID NOT breakdown

Note(s): --

4.4.5

TABLE: protection against moving fan blades
Fan location

P

Mass of fan
assembly (m) (kg)

Radius of fan
blade (r) (mm)

Rotational speed
(N) (r/min)

K factor
calculated

0.008

20

5500

58.08

Left side of enclosure
Classification of fan **)

Result

a). not likely to cause pain or injury

fan of classification a): 0.39

b). likely to cause pain, but not likely to cause injury

fan of classification b):

c). does not comply with a) or b), likely to cause injury

fan of classification c):

Note(s):
*) K factor calculation: K = 6 x 10-7 (mr2N2)
**) classification of fan calculation:
classification a):

4.5.2

classification b):

TABLE: Thermal requirements

P

Supply voltage (V) ....................................... :

90V, 60Hz

264V, 60Hz



Test times .................................................... :

3hrs 07mins

1hr 50mins

--

Tam a1(C) ................................................. :

See below

See below

--

Tam a2(C) .................................................. :

See below

See below

--

Maximum measured temperature T of
part/at:

Measured
T (C)

Calculate
T (50C)

Measured
(C)

Calculated Allowed
T (50C) Tmax (C)

1. AC inlet, inside

40.7

66.1

32.0

57.0

70

2. CY2 body

37.0

62.4

31.1

56.1

125

3. ZR1 body

40.2

65.6

31.5

56.5

85

4. LF1 winding

47.0

72.4

32.5

57.5

105

5. LF3 winding

51.7

77.1

36.2

61.2

105

6. LF2 winding

53.9

79.3

36.7

61.7

105

7. CX3 body

48.7

74.1

35.7

60.7

85

8. PCB near BD1

61.3

86.7

40.7

65.7

130

9. PCB near Q1

87.1

112.5

55.5

80.5

130

10. PCB near Q2

82.5

107.9

52.2

77.2

130

11. PCB near Q4

69.6

95.0

52.1

77.1

130

Report No.: ACSS1811066
Page 62 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
12. PCB near Q5

60.5

85.9

47.4

72.4

130

13. PCB near D2

81.9

107.3

54.9

79.9

130

14. L21 winding

55.3

80.7

48.9

73.9

105

15. T3 winding

71.1

96.5

48.4

73.4

105

16. T2 winding

61.7

87.1

58.6

83.6

110

17. RT1 body

83.0

108.4

52.2

77.2

130

18. CY5 body

61.5

86.9

57.0

82.0

125

19. DP2 body

59.7

85.1

55.6

80.6

100

20. C11 body

51.7

77.1

42.4

67.4

85

21. T1 winding

52.2

77.6

50.1

75.1

110

22. PCB near D3

56.8

82.2

49.9

74.9

130

23. PCB near D7

63.5

88.9

61.8

86.8

130

24. PCB near D8

63.9

89.3

62.6

87.6

130

25. PCB near D5

49.9

75.3

47.8

72.8

130

26. Mylar sheet bottom under T2

51.5

76.9

49.6

74.6

125

27. Mylar sheet top under T2

54.1

79.5

51.7

76.7

125

28. Heat sink for U7

47.4

72.8

47.4

72.4

130

29. Heat sink for U3

53.0

78.4

53.7

78.7

130

30. U21 body

42.7

68.1

43.0

68.0

130

31. J4 body

30.9

56.3

31.3

56.3

130

32. Fan body

53.0

78.4

40.4

65.4

--

33. Panel

32.3

57.7

31.8

56.8

80

34. BD2 body

57.7

83.1

48.2

73.2

130

35. Metal enclosure outside top of T2

35.7

61.1

31.7

56.7

70

36. Heat sink for U8

52.2

77.6

52.6

77.6

130

37. Ambient

24.6

50.0

25.0

50.0

--

Note(s): --

4.6.1, 4.6.2

TABLE: opening in enclosure

Opening
position

dimension(mm)

remark

Front

-- No openings.

Top

-- No openings.

Left

P

Height: 3.85mm
Length: 2.85mm, 2.45mm Trapezoid. Cover three circle areas for DC fan: φ37.85mm;
Height: 3.85mm φ37.85mm; φ37.85mm.
Length: 2.05mm, 1.70mm

Right
Rear
TRF No. SRENAV-01V1.4

φ2.25mm Circle. Cover a rectangular area: 22.4mm x 102.4mm.
-- No openings.

Report No.: ACSS1811066
Page 63 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Bottom

-- No openings.

5.1.6 – 5.1.8 TABLE: Touch current measurement
Measured between:

P

Measured
(mA)

Limit
(mA)

Comments/conditions

Line & neutral and output terminal

0.105

0.25

Fuse in, “e” closed

Line & neutral and metal enclosure

0.630

3.5

Fuse in, “e” opened

Note(s): -5.2

TABLE: Electric strength test

P

Test voltage applied between:

Test voltage (V)

Breakdown

1500Vac

No

--

--

- Unit: Primary to metal enclosure

1820Vac

No

- T1: Primary to Core

1820Vac

No

- T1: Secondary to Core

1820Vac

No

--

--

- T1: Primary to Secondary

3000Vac

No

- T2: Core to Primary

3000Vac

No

- T2: Primary to Secondary

3000Vac

No

- Unit: Primary to Secondary output terminals

3000Vac

No

- Unit: Between main poles (Pri.fuse-link disconnected)
Between parts separated by basic or supplementary insulation

Between parts separated by double or reinforced insulation

Note(s):
5.3

No.

1

TABLE: Fault condition test

P

Ambient temperature (C) ................................... :

See below

—

Power source for EUT: Manufacturer, model/type,
output rating ......................................................... :

--

—

Component

Ventilation
openings

Fault

Test
voltage
(V/Hz)

Blocked 240V/
60Hz

TRF No. SRENAV-01V1.4

Test
time

Fuse #

2hours F1
24mins

Fuse.
current
(A)
1.334

Result

Unit operated normally,
Max temperature measured on:
T1 winding:52.1℃;
T2 winding: 70.0℃;
Ambient: 25.0℃.
Recoverable when fault removed,
NCD, NC, NT, NB, NH.

Report No.: ACSS1811066
Page 64 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
2

System Fan
(1&2)

Stalled

240V/
60Hz

2hour
F1
37mins

1.334

Unit operated normally,
Max temperature measured on:
T1 winding:54.3℃;
T2 winding: 78.6℃;
Ambient: 23.7℃.
Recoverable when fault removed,
NCD, NC, NT, NB, NH.

3

(After D5)
5V

O/L

240V/
60Hz

3hours F1
33mins

1.390→
1.440→
1.473→
0.3

Unit shut down when overloaded to
5.4A.No damaged,nohazardous.
T1 winding:75.7℃;
T2 winding: 65.3℃;
Ambient: 24.0℃..
Recoverable when fault removed,
NCD, NC, NT, NB, NH.

4

(After
D6,D7)55V

O/L

240V/
60Hz

3hours F1
21mins

1.797→
1.847→
1.870→
0.34

Unit shut down when overloaded to
2.4A.No damaged,nohazardous.
T1 winding:57.2℃;
T2 winding:75.2℃;
Ambient: 25.6℃..
Recoverable when fault removed,
NCD, NC, NT, NB, NH.

5

DB1

S/C

240V/
60Hz

1 Sec

F1

0

Unit shutdown immediately, Fuse
F1opened. NB, NH, NT,NC.

6

C11

S/C

240V/
60Hz

1 Sec

F1

0

Unit shutdown immediately, Fuse F1
opened. NB, NH,NT,NC.

7

U9
S/C
Pin12 –pin14

240V/
60Hz

10mins F1

0.105

Unit shutdown immediately, CD(U9),
NT,NC,NB,NH.

8

U9
S/C
Pin12 –Pin10

240V/
60Hz

10mins F1

0.133

Unit shutdown immediately.
Recoverable when fault removed,
NCD, NC, NT, NB, NH.

9

Q1
PinG- PinS

S/C

240V/
60Hz

10mins

F1

1.323

Normal operation, NCD, NC, NT,
NB, NH.

10

Q1
PinG- PinD

S/C

240V/
60Hz

1 Sec

F1

0

Unit shutdown immediately, F1
opened
CD(Q2,Q1) NB, NH NC,NT.

11

Q1
PinS- PinD

S/C

240V/
60Hz

1 Sec

F1

0

Unit shutdown immediately, Fuse F1
opened. NB, NH NT,NC.

12

Q2
PinG- PinS

S/C

240V/
60Hz

10mins

F1

1.323

Normal operation, NCD, NC, NT,
NB, NH.

13

Q2
PinG- PinD

S/C

240V/
60Hz

1 Sec

F1

0

Unit shutdown immediately, Fuse F1
opened. NB, NH NT,NC.

14

Q2
PinS- PinD

S/C

240V/
60Hz

1 Sec

F1

0

Ditto.

15

Q4
PinG- PinS

S/C

240V/
60Hz

10mins F1

0.140

Unit shutdown immediately.
Recoverable when fault removed,
NCD, NC, NT, NB, NH.

16

Q4
PinG- PinD

S/C

240V/
60Hz

10mins F1

0.140

Ditto.

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 65 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
17

Q4
PinS- PinD

S/C

240V/
60Hz

10mins F1

0.152

Ditto.

18

Q5
PinG- PinS

S/C

240V/
60Hz

10mins F1

0.149

Ditto.

19

Q5
PinG- PinD

S/C

240V/
60Hz

10mins F1

0.152

Ditto.

20

Q5
PinS- PinD

S/C

240V/
60Hz

10mins F1

0.152

Ditto.

21

OP1
Pin1- Pin 2

S/C

240V/
60Hz

10mins F1

0.126

Ditto.

22

OP1
Pin3- Pin 4

S/C

240V/
60Hz

10mins F1

0.127

Ditto.

23

OP1 Pin1

O/C

10mins F1

0.126

Ditto.

24

OP1 Pin3

O/C

10mins F1

0.126

Ditto.

25

OP2
Pin1- Pin 2

S/C

240V/
60Hz
240V/
60Hz
240V/
60Hz

10mins F1

1.323

Normal operation,
NCD,NT,NC,NB, NH.

26

OP2
Pin3- Pin 4

S/C

240V/
60Hz

10mins F1

0.127

Unit shutdown immediately.
Recoverable when fault removed,
NCD, NC, NT, NB, NH.

27

OP2 Pin1

O/C

240V/
60Hz

10mins F1

1.320

Normal operation,
NCD,NT,NC,NB, NH.

28

OP2 Pin3

O/C

240V/
60Hz

10mins F1

0.127

Unit shutdown immediately.
Recoverable when fault removed,
NCD, NC, NT, NB, NH.

29

OP3
Pin1- Pin 2

S/C

240V/
60Hz

10mins F1

0.107↔
0.243

Unit shut down and cycle,
0.14W↔10.89W, Recoverable
NCD, NH

30

OP3
Pin3- Pin 4

S/C

240V/
60Hz

10mins F1

0.107

Unit shutdown immediately.
Recoverable when fault removed,
NCD, NC, NT, NB, NH.

31

OP3 Pin1

O/C

240V/
60Hz

10mins F1

0.107↔
0.243

32

OP3 Pin3

O/C

240V/
60Hz

10mins F1

0.107↔
0.243

Unit shut down and cycle,
0.14W↔10.89W, Recoverable
NCD, NH
Unit shut down and cycle,
0.14W↔10.89W, Recoverable
NCD, NH

Note(s):--

TRF No. SRENAV-01V1.4

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment A: Photo-documentation

Page 1 of 5

Fig. 1 - Overview (1)

Fig. 2 - Overview (2)

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 66 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment A: Photo-documentation

Page 2 of 5

Fig. 3 - Internal view (1)

Fig. 4 - Internal view (2)

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 67 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment A: Photo-documentation

Page 3 of 5

Fig. 5 - Internal view (3)

Fig. 6 - Power board overview 1

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 68 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment A: Photo-documentation

Page 4 of 5

Fig. 7 - Power board overview 2

Fig. 8 - Main board overview 1
TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 69 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment A: Photo-documentation

Page 5 of 5

Fig. 9 –Main board overview 2

Fig. 10 –terminals

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 70 of 83

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment B: Drawing of Heatsink(HS1)

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 71 of 83
Page 1 of 6

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment B: Drawing of Heatsink(HS2)

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 72 of 83
Page 2 of 6

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment B: Drawing of Heatsink(HS3)

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 73 of 83
Page 3 of 6

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment B: Drawing of Heatsink(HS4)

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 74 of 83
Page 4 of 6

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment B: Drawing of Heatsink(HS5)

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 75 of 83
Page 5 of 6

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment B: Drawing of Heatsink on the Power board

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 76 of 83
Page 6 of 6

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment C: Schematic diagram and layout for power board

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 77 of 83
Page 1 of 3

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment C: Schematic diagram and layout for power board

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 78 of 83
Page 2 of 3

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment C: Schematic diagram and layout for power board

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 79 of 83
Page 3 of 3

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment D: Transformer T1 specification

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 80 of 83
Page 1 of 2

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment D: Transformer T1 specification

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 81 of 83
Page 2 of 2

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment E: Transformer T2 specification

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 82 of 83
Page 1 of 2

AUDIX TECHNOLOGY (SHENZHEN) CO., LTD
Attachment E: Transformer T2 specification

--- End of this page ---

TRF No. SRENAV-01V1.4

Report No.: ACSS1811066
Page 83 of 83
Page 2 of 2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
Create Date                     : 2018:11:30 09:39:53+08:00
Modify Date                     : 2018:11:30 10:03:20+08:00
Metadata Date                   : 2018:11:30 10:03:20+08:00
Producer                        : EPSON Scan
Format                          : application/pdf
Document ID                     : uuid:5dcb8d23-c78a-4c32-91eb-9c7cde25dcaa
Instance ID                     : uuid:15dc9a30-645f-4d3e-b9cd-52f010042981
Has XFA                         : No
Page Count                      : 84
EXIF Metadata provided by EXIF.tools

Navigation menu